Main catalog
Motor protection and control
Manual motor starters, contactors
and overload relays
Motor rated operational powers and currents
The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz 1800 r.p.m. at 60 Hz).
These values are given for guidance and may vary according to the motor manufacturer and depending on the number of poles.
Motor nominal current: standardized values in blue colour
(according to IEC 60947-4-1 Annex G)
UL / CSA
Motor nominal current: standardized values
(according to IEC 60947-4-1 Annex G and UL 508)
Motor
power
220 V 230 V 240 V 380 V 400 V 415 V 440 V 500 V 660 V 690 V
Motor
power
208 V
220-240 V
380-415 V
440-480 V
kW
A
A
A
A
A
A
A
A
A
A
hp
A
A
A
A
A
0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
400
500
560
630
710
800
900
1000
0.37
0.54
0.73
1
1.6
2.0
2.7
3.5
4.9
6.6
8.9
11.8
15.7
20.9
28.2
39.7
53.3
63.8
75.3
100
120
146
177
240
291
355
418
509
637
782
983
1109
1255
1545
1727
1928
2164
2446
2760
3042
0.35
0.52
0.7
1
1.5
1.9
2.6
3.3
4.7
6.3
8.5
11.3
15
20
27
38
51
61
72
96
115
140
169
230
278
340
400
487
609
748
940
1061
1200
1478
1652
1844
2070
2340
2640
2910
0.34
0.50
0.67
1
1.4
1.8
2.5
3.2
4.5
6
8.1
10.8
14.4
19.2
25.9
36.4
48.9
58.5
69
92
110
134
162
220
266
326
383
467
584
717
901
1017
1150
1416
1583
1767
1984
2243
2530
2789
0.21
0.32
0.46
0.63
0.9
1.2
1.6
2.0
2.8
3.8
5.2
6.8
8.9
12.1
16.3
23.2
30.5
36.8
43.2
57.9
69
84
102
139
168
205
242
295
368
453
568
642
726
895
1000
1116
1253
1417
1598
1761
0.2
0.3
0.44
0.6
0.85
1.1
1.5
1.9
2.7
3.6
4.9
6.5
8.5
11.5
15.5
22
29
35
41
55
66
80
97
132
160
195
230
280
350
430
540
610
690
850
950
1060
1190
1346
1518
1673
0.19
0.29
0.42
0.58
0.82
1.1
1.4
1.8
2.6
3.5
4.7
6.3
8.2
11.1
14.9
21.2
28
33.7
39.5
53
64
77
93
127
154
188
222
270
337
414
520
588
665
819
916
1022
1147
1297
1463
1613
0.18
0.26
0.39
0.53
0.74
1
1.3
1.7
2.4
3.2
4.3
5.7
7.4
10.1
13.6
19.3
25.4
30.7
35.9
48.2
58
70
85
116
140
171
202
245
307
377
473
535
605
745
832
929
1043
1179
1330
1466
0.16
0.24
0.32
0.48
0.68
0.88
1.2
1.5
2.2
2.9
3.9
5.2
6.8
9.2
12.4
17.6
23
28
33
44
53
64
78
106
128
156
184
224
280
344
432
488
552
680
760
848
952
1076
1214
1339
0.13
0.18
0.24
0.37
0.51
0.67
0.91
1.15
1.7
2.2
2.9
4
5.1
7
9.3
13.4
17.8
22
25.1
33.5
40.8
49.1
59.6
81
97
118
140
169
212
261
327
370
418
515
576
643
721
815
920
1014
0.12
0.17
0.23
0.35
0.49
0.64
0.87
1.1
1.6
2.1
2.8
3.8
4.9
6.7
8.9
12.8
17
21
24
32
39
47
57
77
93
113
134
162
203
250
313
354
400
493
551
615
690
780
880
970
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
350
400
450
500
2.4
3.5
4.6
6.6
7.5
10.6
16.7
24.2
30.8
46.2
59.4
74.8
88
114
143
169
211
273
343
396
528
–
–
–
–
–
–
2.2
3.2
4.2
6
6.8
9.6
15.2
22
28
42
54
68
80
104
130
154
192
248
312
360
480
604
722
828
954
1030
1180
1.3
1.8
2.3
3.3
4.3
6.1
9.7
14
18
27
34
44
51
66
83
103
128
165
208
240
320
403
482
560
636
–
786
1.1
1.6
2.1
3
3.4
4.8
7.6
11
14
21
27
34
40
52
65
77
96
124
156
180
240
302
361
414
477
515
590
0.9
1.3
1.7
2.4
2.7
3.9
6.1
9
11
17
22
27
32
41
52
62
77
99
125
144
192
242
289
336
382
412
472
550-600 V
1SBC101589S0201
IEC
Motor protection and control
Manual motor starters, contactors and overload relays
1
Overview
2
Manual motor starters
3
B mini contactors
4
AS contactors with screw terminals
5
AF, A and EK contactors with screw terminals
6
AS and AF contactors with spring terminals
7
Overload relays
8
DRAS Enclosed starter
9
R contactors
10
Motor management system
11
S800 self resetting current limiting module
12
General technical data
13
Index
14
Summary_1
Marketing material
1SBC100192C0201 - Edition july 2014
ABB | 1/1
ABB sets a new standard in motor
control and power switching
1
Featuring AF technology as standard, the latest range of
ABB's contactors establishes a new industry benchmark.
The electronically controlled coil offers multiple benefits over
conventional alternatives, and together with ABB's wide
product offering – an optimal configuration, every time.
Access Global Support
The contactor and motor protection range from ABB is compatible with all major national and international standards and
is available worldwide via a global distribution network. One
contactor coil now handles 100 V – 250 V, AC/DC for use in
Europe or Asia as well as North America.
Optimize logistics
With its contactor and motor protection range, ABB has
managed to reduce the number of contactor coils to just four.
The total number of product variants has been reduced by
up to 90%. This simplifies the customers' logistics and cuts
administration costs.
Simplify design
By reducing contactor coil energy consumption by up to 80%,
panels can be built smaller and transformers more compact.
All the features of the AF technology, along with
access to drawings and coordination tables online, simplifies
your design and assembly process.
Secure uptime
Time to prevent stoppages caused by voltage fluctuations.
The AF contactor ensures distinct operation in unstable networks and signifies a major advance in motor control and power switching. Voltage sags, dips and surges pose no threat.
The AF contactor secures your uptime.
1/2 | ABB
1
MacGregor. Keeping turnarounds brief.
Until the AF range was installed, voltage sags were affecting MacGregor's deck cranes.
Conventional contactors welded shut, leading to several stoppages a week. No longer. Known for superior quality and an ability
to operate in the most hostile environments, MacGregor deck cranes enjoy a global reputation for reliability. A small but vital
component, the AF contactor helps maintain this reputation.
To keep things moving, you need Control. Connect to Control.
Explore all our case studies at www.abb.com/connecttocontrol
SSAB
Making certainty
standard
Gamesa
Taming the wind
LKAB
Providing fresh air
ABB | 1/3
Contactors and motor protection
For a wide variety of segments
1
HVAC, General Machinery, Rail, Critical Power, Wind, Solar, Marine and Water & Wastewater
Contactors for any use
The AF contactor range covers small motor starting solutions
from 4 kW / 5 hp up to big power switching solutions with our
unique AF2650, the biggest single case block contactor in the
world.
The contactor and motor protection range is part of one of
the widest product offerings on the market meaning that ABB
not only can provide the contactor but the full solution.
In addition to the standard product range ABB also offer
products for special needs such as Bar contactors, GAF and
contactors for capacitor switching.
1/4 | ABB
Cooperating with customers
ABB cooperates closely with its customers to ensure that
products meet requirements from their specific segments and
applications. With over 100 years' experience in motor control
and power switching ABB knows how to create efficient solutions for its customers.
AF technology
Benefits
1
Reliable in all networks
The electronic system within the AF contactor rectifies the
AC or DC control circuit voltage to a DC control voltage that
is applied on the coil. The contactor is safely operated in an
always optimized condition making it virtually noise free.
Four coils for the entire voltage range
The AF contactor features both AC and DC support. With the
complete AF contactor range, functionality is improved. Still,
the total number of product variants compared to a conventional range is reduced by 90 %. Only four coils are required to
cover 24 V AC, 20 V DC - 500 V AC/DC.
Wide control voltage range
With conventional contactor technology, different contactors
were needed for different network voltages. Thanks to the
wide operating range of the AF contactor it can operate just
as well in Europe as in Asia or North America. The core coil of
the AF contactor range covers 100-250 V AC/DC 50/60 Hz.
Built-in surge suppression
With conventional contactor technology it is recommended
to use an external surge suppressor, an accessory that could
cost as much as half the contactor itself. With the AF technology the surges are handled by the contactor itself and the
surge never reaches the control circuit. Neither the surge suppressor nor the actual surge has to be considered anymore.
One less product and one less complication to worry about.
ABB | 1/5
Contactors and motor protection
Advanced but simple
1
The AF contactor is compact
The AF contactor is compact in size and has had its width
reduced by up to 30 % thanks to an 80 % reduction of the
coil‘s energy consumption.
The AF contactor is flexible
AF09 ... AF370 is perfect for motor starting applications and
for solutions where space is limited. Interlocked reversing
pairs require no spacing between contactors meaning you can
fit more functionality into cabinets or other small enclosures.
Coil terminal access in the front
The AF contactor has its coil terminals accessible from the
front. The cables or bars do not have to be disconnected in
order to perform voltage measurement or servicing work.
More functionality without adding width
The AF116 ... AF2650 can take up to 2 side mounted auxiliary
contact blocks without adding to its width and are delivered
with 1 N.O. + 1 N.C. as standard.
1/6 | ABB
Contactors and motor protection
Mechanical features
1
Easy-to-use accessories
Contactors up to 96 A offer free choice of coil terminal access
and can take side and front mounted auxiliary contact blocks.
All the accessories: Coil connection terminals, mechanical and
electrical interlocks and electronic timers are easily connected
through the snap-to-connect function.
Top-mounted
Bottom-mounted
Additional LDC4
coil terminal block
Front-mounted
Safe control circuit with:
– – Mirror contact according to IEC 60947-4-1
–– Mechanically linked contacts according to IEC 60947-5-1
–– Sealable and transparent protective covers on
AF09 ... AF96 and overload relays TF/EF
ABB | 1/7
3-pole contactors
Mini contactors
Contactors for motor control and
1
IEC (1) AC-3 Rated operational power θ ≤ 60 °C (2), 400 V kW
480 V
UL/CSA 3-phase motor rating
hp
4
5.5
4
5.5
7.5
4
5.5
7.5
11
15
18.5
3
5
5
7.5
10
5
7.5
10
15
20
25
AC / DC Control supply
Type —
—
—
—
—
AF09
AF12
AF16
AF26 AF30 AF38
AC Control supply
Type B6
B7
AS09
AS12
AS16
AF09
AF12
AF16
AF26 AF30 AF38
DC Control supply
Type BC6
BC7
ASL09
ASL12 ASL16
AF09
AF12
AF16
AF26 AF30 AF38
IEC
AC-3 Rated operational current θ ≤ 60 °C (2), 400 V
A
8.5
11.5
9
12
15.5
9
12
18
26
32
AC-1 Rated operational current θ ≤ 40 °C, 690 V
A
20
(400 V)
20
22
24
24
25
28
30
45
50
50
A
12
(300 V)
16
20
20
20
25
28
30
45
50
50
—
00
00
0
00
0
—
1
—
—
UL/CSA General use rating
NEMA
600 V
—
NEMA Size
(400 V)
38
(1) 1000 V IEC ratings available for AF146 ... AF2650 contactors.
(2) θ ≤ 55 °C for mini contactors and AF400 ... AF2650 contactors.
Main accessories
Auxiliary contact blocks
Front mounting
CAF6
Side mounting
CA6
Timers
Electronic
Interlocking units (3)
Mechanical
CA3-10 (1 x N.O.)
CA3-01 (1 x N.C.)
CA4-10 (1 x N.O.)
CA4-01 (1 x N.C.)
CAL4-11 (1 x N.O. + 1 x N.C.)
TEF3-ON
TEF3-OFF
VM3
TEF4-ON
TEF4-OFF
VM4
Mechanical / Electrical
VEM4
Connection sets
For reversing contactors
BSM6-30
BER16C-3
BER16-4
Surge suppressors
Varistor (AC/DC)
RV-BC6
RV5
Built-in surge protection
RC type (AC)
Transil diode (DC)
(24…440 V)
BER38-4
RC5-1 (24…440 V)
RD7
RT5
(12…264 V)
(3) See available reversing contactors VB6, VB7 and VAS09 ... VAS16.
Overload relays
Thermal relays
Class 10
T16
Electronic relays
Class 10E, 20E, 30E
E16DU (0.10…18.9 A)
(Class 10A for TF140, TA200DU)
(0.10…16 A)
T16 (0.10…16 A)
TF42
(0.10…38 A)
EF19
(0.10…18.9 A)
EF19 (0.10…18.9 A)
EF45 (9…45 A)
Manual motor starters
Thermal / magnetic protection MS116 (0.10…32 A)
Ics up to 50 kA for class 10A
Class 10
MS132 (0.10…32 A)
Ics up to 100 kA
MS116 (0.10...32 A)
lcs up to 50 kA for class 10 A
MS450
(28...50 A)
lcs up to 50 kA
MS132 (0.10...32 A)
lcs up to 100 kA
MS497
(22…100 A)
Ics up to 100 kA
Accessories
1/8 | ABB
Magnetic only types
MO132 (0.16...32A)
MO132
For contactor mounting
BEA7/132
BEA16-3
(0.16...32 A)
Ics up to 100 kA
BEA16-4
BEA38-4
power switching
1
18.5 22
30
37
45
55
75
75
90
110
132
160
200
200
250
315
400
—
475
560
—
—
30
50
60
60
75
100
100
125
150
200
250
300
350
400
500
600
—
800
900
—
—
40
AF40 AF52 AF65 AF80 AF96 AF116 AF140 AF146 AF190 AF205 AF265 AF305 AF370 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650 AF2050 AF2650
AF40 AF52 AF65 AF80 AF96 AF116 AF140 AF146 AF190 AF205 AF265 AF305 AF370 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650 AF2050 AF2650
AF40 AF52 AF65 AF80 AF96 AF116 AF140 AF146 AF190 AF205 AF265 AF305 AF370 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650 AF2050 AF2650
40
53
116
140
146
190
205
265
305
370
400
460
580
750
860
1050
—
—
70
100 105
125 130
160
200
225
275
350
400
500
600
600
700
800
1050 1260
1350
1650
2050
2650
60
80
90
105 115
160
200
200
250
300
350
400
520
550
650
750
900
1210
1350
1650
2100
2700
2
—
—
3
—
4
—
—
—
5
—
—
—
6
—
7
—
—
8
—
—
65
80
96
—
VM96-4
CAL19-11 (1 x N.O. + 1 x N.C.)
CAL18-11 (1 x N.O. + 1 x N.C.)
VM19
VM750H
VM750V
(for same size contactors)
BER65-4
BER96-4 BER140-4
BER205-4
TF65
(22...67 A)
TF96
TF140DU
TA200DU
EF65
(20...70 A)
EF96
EF146
EF205
(40...96 A)
(36...100 A)
(66...142 A)
θ ≤ 55 °C
(54...150 A)
—
VM1650H
BER370-4
BEM460-30 BEM750-30
EF370
EF460
(66...200 A)
θ ≤ 55 °C
(63...210 A)
(115...380 A)
(150…500 A)
EF750
(250…800 A)
E1250DU
(375…1250 A)
Short-circuit protection devices
MCCB and switch-fuses
MS495
1SBC101753S0201 - Rev. B
(45…100 A)
Ics up to 50 kA
MO496
(32…100 A)
Ics up to 100 kA
MO450 (40…50 A)
Ics up to 50 kA
MO495
(63…100 A)
Ics up to 50 kA
ABB | 1/9
4-pole contactors
Mini contactors
1
AC-1 Rated operational current
IEC
UL/CSA General use rating
Contactor relays
A
A
16
20
12 (300 V)
16
AC / DC Control supply
Type
—
—
AC Control supply
Type
B6
B7
DC Control supply
Type
BC6
BC7
θ ≤ 40 °C, 690 V
600 V
Mini contactor relays
AC-15 Rated operational current
IEC
UL/CSA Pilot duty
400 V
A
3
A600
2 2
R contactors
3 1
4 0
AC Control supply
Type
K6-22Z
K6-31Z
K6-40E
DC Control supply
Type
KC6-22Z
KC6-31Z
KC6-40E
AC / DC Control supply
Type
—
—
—
DC Circuit switching
DC-1 Rated current up to 5000 A
DC-3/DC-5 Rated current up to 2000 A
1500 V with poles in series
IOR.. 63-..-CC to IOR.. 5100-..-CC
Specific contactors
1/10 | ABB
DC Circuit switching
100 A, 440 V, DC-1
275 to 2050 A, 1000 V, DC-1
GA75, GAE75 types
GAF185 to GAF2050 types
Contactors
1
25
30
45
55
70
100
125
160
200
275
350
400
500
525
800
1000
25
30
45
55
—
—
—
—
—
—
—
—
—
—
540
—
AF09
AF16
AF26
AF38
AF40
AF52
AF80
AF116
AF140
AF190
AF205
AF265
AF305
AF370
—
—
AF09
AF16
AF26
AF38
AF40
AF52
AF80
AF116
AF140
AF190
AF205
AF265
AF305
AF370
EK550
EK1000
AF09
AF16
AF26
AF38
AF40
AF52
AF80
AF116
AF140
AF190
AF205
AF265
AF305
AF370
EK550
EK1000
Contactor relays
3
3
A600, Q300
A600, Q600
2 2
3 1
4 0
2 2
3 1
4 0
NS22E
NS31E
NS40E
NF22E
NF31E
NF40E
NSL22E
NSL31E
NSL40E
NF22E
NF31E
NF40E
—
—
—
NF22E
NF31E
NF40E
AC Circuit switching
Special versions
AC-1 Rated current up to 5000 A
AC-3 Rated power up to 1500 kW
(1520 A - 440 V)
AC/DC Coupling: LOR.. contactors
IOR.. 63-..-MT to IOR.. 5100-..-MT
AC/DC Switching (N.C./N.O. main poles):
NOR & JOR contactors
Slip ring motor control: FOR .. contactors
Field discharge: AM(F)-CC-JORE contactors
Latching contactors for energy saving
and safety requirements: AMA or AME contactors
1SBC101638S0201 - Rev. C
Capacitor switching
12.5 to 80 kvar
UA16..RA to UA110..RA types
UA16 to UA110 types
ABB | 1/11
Summary_2
2
2/0 | ABB
Manual motor starters
Overview
Manual motor starters
2/2
0.10 to 32 A – with thermal and electromagnetic protection
2
I CS up to 50 kA
MS116 manual motor starters
2/4
I CS up to 100 kA
MS132 manual motor starters
2/5
0.16 to 32 A – with electromagnetic protection
MO132 manual motor starters magnetic only
2/6
0.10 to 25 A – with thermal and electromagnetic protection
MS132-T circuit breakers for transformer protection
2/7
2/8
2/14
22 to 100 A – with thermal and electromagnetic protection
MS450, MS495, MS497 manual motor starters
Technical data
2/23
2/24
32 to 100 A – with electromagnetic protection
MO450, MO495, MO496 manual motor starters magnetic only
Technical data
2/27
2/28
Main accessories
2/31
General accessories
2/38
Summary_2
Technical data
Main accessories
ABB | 2/1
Manual motor starters
2
Type
MS116
MS132
MS450
MS495
Thermal and electromagnetic protection
Yes
Yes
Yes
Yes
Electromagnetic protection
-
-
-
-
Phase loss sensitivity
Yes
Yes
Yes
Yes
Switch position
ON/OFF
ON/OFF/TRIP
ON/OFF/TRIP
ON/OFF/TRIP
Magnetic trip indication
-
Yes
-
-
Lockable handle without accessories
-
Yes
Yes
Yes
Disconnecting feature
Yes
Yes
Yes
Yes
MS497
Width
45 mm
45 mm
55 mm
70 mm
Rated operational current Ie
0.16 ... 32 A
0.16 ... 32 A
40 ... 50 A
63 ... 100 A
32 ... 100 A
Setting range
0.1 ... 32 A
0.1 ... 32 A
28 ... 50 A
45 ... 100 A
22 ... 100 A
Ambient air temperature
-25 ... +55 °C *
-25 ... +60 °C *
)
)
-20 ... +60 °C *
)
-20 ... +60 °C *)
* Compensated
)
Table for short-circuit ratings for 400 V
Standard range
High performance range
MS116, MS450, MS495
MS132, MS497
Type
Type
Selection parameters
Rated operational
power
Setting range for
thermal release
Short-circuit
breaking capacity
Icu
I cs
Short-circuit
breaking capacity
I cu
I cs
0.03 kW
0.1 … 0.16 A
MS116-0.16
50 kA
50 kA
MS132-0.16
100 kA
100 kA
0.06 kW
0.16 … 0.25 A
MS116-0.25
50 kA
50 kA
MS132-0.25
100 kA
100 kA
0.09 kW
0.25 … 0.4 A
MS116-0.4
50 kA
50 kA
MS132-0.4
100 kA
100 kA
0.18 kW
0.4 … 0.63 A
MS116-0.63
50 kA
50 kA
MS132-0.63
100 kA
100 kA
0.25 kW
0.63 … 1.0 A
MS116-1.0
50 kA
50 kA
MS132-1.0
100 kA
100 kA
0.55 kW
1.0 … 1.6 A
MS116-1.6
50 kA
50 kA
MS132-1.6
100 kA
100 kA
0.75 kW
1.6 … 2.5 A
MS116-2.5
50 kA
50 kA
MS132-2.5
100 kA
100 kA
1.5 kW
2.5 … 4.0 A
MS116-4.0
50 kA
50 kA
MS132-4.0
100 kA
100 kA
2.2 kW
4.0 … 6.3 A
MS116-6.3
50 kA
50 kA
MS132-6.3
100 kA
100 kA
4.0 kW
6.3 … 10 A
MS116-10
50 kA
50 kA
MS132-10
100 kA
100 kA
5.5 kW
8 … 12 A
MS116-12
25 kA
25 kA
MS132-12
100 kA
100 kA
7.5 kW
10 … 16 A
MS116-16
16 kA
16 kA
MS132-16
100 kA
100 kA
9.0 kW
16 … 20 A
MS116-20
15 kA
10 kA
MS132-20
100 kA
100 kA
12.5 kW
20 … 25 A
MS116-25
15 kA
10 kA
MS132-25
50 kA
50 kA
15 kW
25 … 32 A
MS116-32
10 kA
10 kA
MS132-32
50 kA
25 kA
15 kW
22 … 32 A
MS132-32
50 kA
25 kA
MS497-32
100 kA
50 kA
18.5 kW
28 … 40 A
MS450-40
50 kA
25 kA
MS497-40
100 kA
50 kA
22 kW
36 … 45 A
MS450-45
50 kA
25 kA
MS497-50
100 kA
50 kA
22 kW
40 … 50 A
MS450-50
50 kA
25 kA
MS497-50
100 kA
50 kA
30 kW
45 … 63 A
MS495-63
50 kA
25 kA
MS497-63
100 kA
50 kA
37 kW
57 … 75 A
MS495-75
50 kA
25 kA
MS497-75
100 kA
50 kA
45 kW
70 … 90 A
MS495-90
50 kA
25 kA
MS497-90
100 kA
50 kA
55 kW
80 … 100 A
MS495-100
50 kA
25 kA
MS497-100
100 kA
50 kA
The currents given above concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz 1800 r.p.m. at 60 Hz).
2/2 | ABB
MO132
MO450
MO495
-
-
-
Yes
Yes
Yes
Yes
-
-
-
-
Yes
ON/OFF/TRIP
ON/OFF/TRIP
ON/OFF/TRIP
ON/OFF/TRIP
-
-
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
45 mm
55 mm
70 mm
0.16 ... 32 A
40 ... 50 A
63 ... 100 A
-
-
-
0.1 ... 25 A
-25 ... +60 °C
-20 ... +60 °C
-20 ... +60 °C
-25 ... +60 °C *)
Standard range
High performance range
Transformer protection
MO132, MO450, MO495
MO132, MO496
MS132-T
Type
Type
Short-circuit
breaking capacity
Icu
Ics
MO132-0.16
100 kA
100 kA
MO132-0.25
100 kA
100 kA
MO132-0.4
100 kA
MO132-0.63
MO132-1.0
MO496
MS132-T
2
45 mm
32 ... 100 A
Short-circuit
breaking capacity
0.16 ... 32 A
Type
Short-circuit
breaking
capacity
I cu
Ics
I cu / Ics
MO132-0.16
100 kA
100 kA
MS132-0.16T
100 kA
MO132-0.25
100 kA
100 kA
MS132-0.25T
100 kA
100 kA
MO132-0.4
100 kA
100 kA
MS132-0.4T
100 kA
100 kA
100 kA
MO132-0.63
100 kA
100 kA
MS132-0.63T
100 kA
100 kA
100 kA
MO132-1.0
100 kA
100 kA
MS132-1.0T
100 kA
MO132-1.6
100 kA
100 kA
MO132-1.6
100 kA
100 kA
MS132-1.6T
100 kA
MO132-2.5
100 kA
100 kA
MO132-2.5
100 kA
100 kA
MS132-2.5T
100 kA
MO132-4.0
100 kA
100 kA
MO132-4.0
100 kA
100 kA
MS132-4.0T
100 kA
MO132-6.3
100 kA
100 kA
MO132-6.3
100 kA
100 kA
MS132-6.3T
100 kA
MO132-10
100 kA
100 kA
MO132-10
100 kA
100 kA
MS132-10T
100 kA
MO132-12
100 kA
100 kA
MO132-12
100 kA
100 kA
MS132-12T
100 kA
MO132-16
100 kA
100 kA
MO132-16
100 kA
100 kA
MS132-16T
100 kA
MO132-20
100 kA
100 kA
MO132-20
100 kA
100 kA
MS132-20T
100 kA
MO132-25
50 kA
50 kA
MO132-25
50 kA
50 kA
MS132-25T
MO132-32
50 kA
25 kA
MO132-32
50 kA
25 kA
MO132-32
50 kA
25 kA
MO496-32
100 kA
50 kA
MO450-40
50 kA
25 kA
MO496-40
100 kA
50 kA
MO450-45
50 kA
25 kA
MO496-50
100 kA
50 kA
MO450-50
50 kA
25 kA
MO496-50
100 kA
50 kA
MO495-63
50 kA
25 kA
MO496-63
100 kA
50 kA
MO495-75
50 kA
25 kA
MO496-75
100 kA
50 kA
MO495-90
50 kA
25 kA
MO496-90
100 kA
50 kA
MO495-100
50 kA
25 kA
MO496-100
100 kA
50 kA
50 kA
Transformer protection:
The instantaneous short-circuit
current setting is 20 times the
rated operational current.
For motor protection, an appropriate thermal or electronic overload relay must be used.
ABB | 2/3
MS116 manual motor starters
0.10 to 32 A – with thermal and electromagnetic protection
Description
2CDC241010F0011
2
MS116-16
Manual motor starters (MMS) are protection devices for the main circuit. They combine motor control and
protection in a single device. MMS are used mainly to switch motors manually ON/OFF and protect them
and the installation fuse-less against short-circuit, overload and phase failures. Fuse-less protection with
a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by
switching off the motor within milliseconds.
MS116 is a compact and economic range for motor protection up to 15.5 kW (400 V) / 32 A in width of 45 mm.
Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and
a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and
single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, threephase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes
are available as accessory.
Rated instantaneous shortcircuit current
setting li
A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
16.0 ... 20.0
20.0 ... 25.0
25.0 ... 32.0
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
16.0 ... 20.0
20.0 ... 25.0
25.0 ... 32.0
kA
50
50
50
50
50
50
50
50
50
50
25
16
10
10
10
50
50
50
50
50
50
50
50
50
50
25
16
10
10
10
A
1.56
2.44
3.90
6.14
11.50
18.40
28.75
50.00
78.75
150
180
240
300
375
480
1.56
2.44
3.90
6.14
11.50
18.40
28.75
50.00
78.75
150
180
240
300
375
480
kg
0.225
0.225
0.225
0.225
0.225
0.265
0.265
0.265
0.265
0.265
0.265
0.265
0.310
0.310
0.310
0.240
0.240
0.240
0.240
0.240
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.326
0.326
0.326
79.9 3.15"
69.8 2.75"
1.7"
1.77"
2CDC242001F0011
14 0.55"
45
MS116 ≥ 20 A & MS116-HKF1-11 ≥ 20 A
1.77"
43.3
2CDC131062C0201
14 0.55"
0.22"
2.3"
2.95"
27.5 1.1"
1.77"
45
MS116 ≤ 16 A & MS116-HKF1-11 ≤ 16 A
1.7 0.07"
1.38"
35
14 0.55"
5.5
0.06"
45
1.5
57.8
3.15"
2.76"
1.71"
2.95"
27.5 1.1"
43.5
75
1.7 0.07"
3.54"
90
1SAM250000R1001
1SAM250000R1002
1SAM250000R1003
1SAM250000R1004
1SAM250000R1005
1SAM250000R1006
1SAM250000R1007
1SAM250000R1008
1SAM250000R1009
1SAM250000R1010
1SAM250000R1012
1SAM250000R1011
1SAM250000R1013
1SAM250000R1014
1SAM250000R1015
1SAM250005R1001
1SAM250005R1002
1SAM250005R1003
1SAM250005R1004
1SAM250005R1005
1SAM250005R1006
1SAM250005R1007
1SAM250005R1008
1SAM250005R1009
1SAM250005R1010
1SAM250005R1012
1SAM250005R1011
1SAM250005R1013
1SAM250005R1014
1SAM250005R1015
35 1.38"
70
0.22"
45 1.77"
2/4 | ABB
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
MS116-0.16-HKF1-11
MS116-0.25-HKF1-11
MS116-0.4-HKF1-11
MS116-0.63-HKF1-11
MS116-1.0-HKF1-11
MS116-1.6-HKF1-11
MS116-2.5-HKF1-11
MS116-4.0-HKF1-11
MS116-6.3-HKF1-11
MS116-10.0-HKF1-11
MS116-12.0-HKF1-11
MS116-16.0-HKF1-11
MS116-20-HKF1-11
MS116-25-HKF1-11
MS116-32-HKF1-11
75
80.1
14 0.55"
Weight
(1 pce)
mm, inches
1.5 0.06"
5.5
Order code
3.85"
Main dimensions
Type
97.8
MS116-32-HKF1-11
Short-circuit
breaking
capacity ICS at
400 V AC
2CDC242002F0010
2CDC241012F0011
MS116-0.16-HKF1-11
Setting
range
2.3"
2CDC241013F0011
MS116-25
Rated
operational
power
400 V
AC-3
kW
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4.0
5.5
7.5
9.0
12.5
15.5
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4.0
5.5
7.5
9.0
12.5
15.5
57.8
2CDC241001F0011
Ordering details
MS132 manual motor starters
0.10 to 32 A – with thermal and electromagnetic protection
1SBC101232F0010
Description
MS132-10
Manual motor starters (MMS) are protection devices for the main circuit. They combine motor control and
protection in a single device. MMS are used mainly to switch motors manually ON/OFF and protect them and
the installation fuse-less against short-circuit, overload and phase failures. Fuse-less protection with a manual
motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off
the motor within milliseconds.
MS132 is a compact and powerful range for motor protection up 15.5 kW (400 V) / 32 A in width of 45 mm.
This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit
tripping. Further features are the build-in disconnect function, temperature compensation, trip-free
mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable
for three- and single-phase applications. The handle is lockable to protect against unauthorized changes.
Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, three-phase bus bars, power
in-feed blocks.
2
Short-circuit
breaking
capacity ICS at
400 V AC
Rated instantaneous shortcircuit current
setting li
A
0.10 … 0.16
0.16 … 0.25
0.25 … 0.40
0.40 … 0.63
0.63 … 1.00
1.00 … 1.60
1.60 … 2.50
2.50 … 4.00
4.00 … 6.30
6.30 … 10.0
8.00 … 12.0
10.0 … 16.0
16.0 … 20.0
20.0 … 25.0
25.0 … 32.0
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
16.0 ... 20.0
20.0 ... 25.0
25.0 ... 32.0
kA
100
100
100
100
100
100
100
100
100
100
100
100
100
50
25
100
100
100
100
100
100
100
100
100
100
100
100
100
50
25
A
1.56
2.44
3.90
6.14
11.50
18.40
28.75
50.00
78.75
150
180
240
300
375
480
1.56
2.44
3.90
6.14
11.50
18.40
28.75
50.00
78.75
150
180
240
300
375
480
Main dimensions
Type
Order code
Weight
(1 pce)
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-20
MS132-25
MS132-32
MS132-0.16-HKF1-11
MS132-0.25-HKF1-11
MS132-0.4-HKF1-11
MS132-0.63-HKF1-11
MS132-1.0-HKF1-11
MS132-1.6-HKF1-11
MS132-2.5-HKF1-11
MS132-4.0-HKF1-11
MS132-6.3-HKF1-11
MS132-10.0-HKF1-11
MS132-12.0-HKF1-11
MS132-16.0-HKF1-11
MS132-20-HKF1-11
MS132-25-HKF1-11
MS132-32-HKF1-11
1SAM350000R1001
1SAM350000R1002
1SAM350000R1003
1SAM350000R1004
1SAM350000R1005
1SAM350000R1006
1SAM350000R1007
1SAM350000R1008
1SAM350000R1009
1SAM350000R1010
1SAM350000R1012
1SAM350000R1011
1SAM350000R1013
1SAM350000R1014
1SAM350000R1015
1SAM350005R1001
1SAM350005R1002
1SAM350005R1003
1SAM350005R1004
1SAM350005R1005
1SAM350005R1006
1SAM350005R1007
1SAM350005R1008
1SAM350005R1009
1SAM350005R1010
1SAM350005R1012
1SAM350005R1011
1SAM350005R1013
1SAM350005R1014
1SAM350005R1015
kg
0.215
0.215
0.215
0.215
0.215
0.265
0.265
0.265
0.265
0.265
0.310
0.310
0.310
0.310
0.310
0.231
0.231
0.231
0.231
0.231
0.281
0.281
0.281
0.281
0.281
0.326
0.326
0.326
0.326
0.326
mm, inches
81.05 3.19"
72.2
81.25 3.2"
72.4
2.84"
0.22"
45 1.77"
2CDC242016F0009
14 0.55"
45 1.77"
35 1.38"
75 2.95"
1.7 0.1"
97.8 3.85"
14 0.55"
MS132 ≥ 12 A
ABB | 2/5
2CDC131062C0201
MS132 ≤ 10 A
43.3
1.71"
2CDC242015F0009
14 0.55"
45 1.77"
43.5
5.5 0.22"
1.5 0.06"
2.85"
45" 1.77"
2.95"
14 0.55"
35 1.38"
5.5 0.22"
1.5 0.06"
75
MS132-32-HKF1-11
Setting
range
1.7 0.1"
2CDC241015F0011
MS132-0.16-HKF1-11
3.54"
2CDC241014F0011
MS132-32
Rated
operational
power
400 V
AC-3
kW
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4.0
5.5
7.5
9.0
12.5
15.5
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4.0
5.5
7.5
9.0
12.5
15.5
90
2CDC241001F0011
Ordering details
MO132 manual motor starters magnetic only
0.16 to 32 A – with electromagnetic protection
Description
2CDC241009F0011
2
2CDC241008F0011
MO132-6.3
MO132-32
Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are
used mainly to switch motors manually ON/OFF and protect them fuse-less against short-circuit.
Fuse-less protection with a manual motor starter saves costs, space and ensures a quick reaction under
short-circuit condition, by switching off the motor within milliseconds. Fuse-less starter combinations are setup
together with contactors and overload relays.
Ordering details
Rated
operational
power
400 V
AC-31)
kW
0.03
0.06
0.09
0.12
0.25
0.55
0.75
1.5
2.2
4.0
5.5
7.5
9.0
12.5
15.5
1)
Rated
Short-circuit
operational breaking
current
capacity ICS at
400 V AC
Rated instantaneous shortcircuit current
setting li
A
0.16
0.25
0.40
0.63
1.0
1.6
2.5
4.0
6.3
10
12
16
20
25
32
A
1.56
2.44
3.90
6.14
11.50
18.40
28.75
50.00
78.75
125.00
150.00
200.00
250.00
312.50
400.00
kA
100
100
100
100
100
100
100
50
50
50
50
50
50
50
25
Type
Order code
Weight
(1 pce)
MO132-0.16
MO132-0.25
MO132-0.4
MO132-0.63
MO132-1.0
MO132-1.6
MO132-2.5
MO132-4.0
MO132-6.3
MO132-10
MO132-12
MO132-16
MO132-20
MO132-25
MO132-32
1SAM360000R1001
1SAM360000R1002
1SAM360000R1003
1SAM360000R1004
1SAM360000R1005
1SAM360000R1006
1SAM360000R1007
1SAM360000R1008
1SAM360000R1009
1SAM360000R1010
1SAM360000R1012
1SAM360000R1011
1SAM360000R1013
1SAM360000R1014
1SAM360000R1015
kg
0.215
0.215
0.215
0.215
0.215
0.265
0.265
0.265
0.265
0.265
0.310
0.310
0.310
0.310
0.310
For overload protection of motors, an appropriate thermal or electronic overload relay must be used
Main dimensions
mm, inches
81.05 3.19"
72.2
81.25 3.2"
72.4
2/6 | ABB
2.84"
0.22"
14 0.55"
14 0.55"
45 1.77"
MO132 ≥ 12 A
45 1.77"
35 1.38"
1.7 0.1"
75 2.95"
45" 1.77"
97.8 3.85"
1.71"
2CDC131062C0201
MO132 ≤ 10 A
43.3
2CDC242006F0011
14 0.55"
45 1.77"
43.5
2CDC242005F0011
75
2.95"
1.7 0.1"
3.54"
90
14 0.55"
35 1.38"
5.5 0.22"
1.5 0.06"
5.5 0.22"
1.5 0.06"
2.85"
MS132-T circuit breakers for transformer protection
0.10 to 25 A – with thermal and electromagnetic protection
2CDC241001F0014
Description
MS132-10T
Circuit breakers for transformer protection are electro mechanical protection devices specially designed to
protect control transformers on the primary side. They allow fuse-less protection against overload and shortcircuit, saving space and cost and ensuring a quick reaction under short-circuit condition by switching off
the transformer within milliseconds. The short-circuit current setting is fixed to 20 times the operating current
to handle the high inrush current generated by transformers. The device allows manual connection and
disconnection of the transformer from the mains.
MS132-T is a 45 mm (width) compact and powerful range for transformer protection up to 12.5 kW (400 V)
/ 25 A. This type has also a clear and reliable indication of fault in a seperate window in the event of shortcircuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free
mechanism and a rotary handle with a clear switch position indication. The handle is lockable to protect against
unauthorized changes. Furthermore it is possible to use the existing MS116/MS132 manual motor starter
accessories like auxiliary contacts, signaling contacts, undervoltage releases, shunt trips and power in-feed
blocks. Moreover ABB offers special accessories for fast single phase setup.
2
Ordering details
A
0.10 … 0.16
0.16 … 0.25
0.25 … 0.40
0.40 … 0.63
0.63 … 1.00
1.00 … 1.60
1.60 … 2.50
2.50 … 4.00
4.00 … 6.30
6.30 … 10.0
8.00 … 12.0
10.0 … 16.0
16.0 … 20.0
20.0 … 25.0
Rated instantaneous short-circuit
current setting li
A
3.2
5
8
12.6
20
32
50
80
126
200
240
320
400
500
Type
Order code
Weight
(1 pce)
MS132-0.16T
MS132-0.25T
MS132-0.4T
MS132-0.63T
MS132-1.0T
MS132-1.6T
MS132-2.5T
MS132-4.0T
MS132-6.3T
MS132-10T
MS132-12T
MS132-16T
MS132-20T
MS132-25T
1SAM340000R1001
1SAM340000R1002
1SAM340000R1003
1SAM340000R1004
1SAM340000R1005
1SAM340000R1006
1SAM340000R1007
1SAM340000R1008
1SAM340000R1009
1SAM340000R1010
1SAM340000R1012
1SAM340000R1011
1SAM340000R1013
1SAM340000R1014
kg
0.215
0.215
0.215
0.215
0.215
0.265
0.265
0.265
0.265
0.265
0.310
0.310
0.310
0.310
Please check for single-phase equipment chapter Main accessories.
Main dimensions
mm, inches
81.05 3.19"
72.2
81.25 3.2"
72.4
43.3
2.84"
0.22"
14 0.55"
45 1.77"
45 1.77"
2CDC242016F0009
14 0.55"
35 1.38"
75 2.95"
1.7 0.1"
97.8 3.85"
1.71"
MS132T ≥ 12 A
ABB | 2/7
2CDC131062C0201
MS132T ≤ 10 A
5.5 0.22"
1.5 0.06"
2CDC242015F0009
14 0.55"
45 1.77"
43.5
2.85"
45" 1.77"
75
2.95"
1.7 0.1"
14 0.55"
35 1.38"
5.5 0.22"
1.5 0.06"
3.54"
MS132-25T
Short-circuit
breaking
capacity ICS at 400
V AC
kA
100
100
100
100
100
100
100
100
100
100
100
100
100
50
90
2CDC241002F0014
Setting range
MS116, MS132, MO132, MS132-T
Technical data
Main circuit – Utilization characteristics according to IEC/EN
MS116
MS132
MO132
IEC/EN 60947–2, IEC/EN 60947-4-1, IEC/EN 60947-1
690 V AC
690 V AC / 250 V DC 690 V AC
50/60 Hz
DC, 50/60 Hz
50/60 Hz
10A
10 (10A for
1SAM350000R1001)
3
100 %
100000 cycles
up to 16 A 100000 cycles
20 ... 32 A 50000 cycles
6 kV
690 V
See ordering details
See "Rated operational current Ie"
See ordering details
See table "Short-circuit breaking capacity and back-up fuses"
See table "Short-circuit breaking capacity and back-up fuses"
10 kA
-
Number of poles
Duty time
Mechanical durability
Electrical durability
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Rated operational current Ie
Rated operational current DC-5 Ie
3 conducting paths in series up to 250 V
Rated instantaneous short-circuit current setting Ii
Rated service short-circuit breaking capacity Ics
Rated ultimate short-circuit breaking capacity Icu
Rated service short-circuit breaking capacity DC Ics
3 conducting paths in series up to 250 V
MS132-T
690 V AC
50/60 Hz
10
-
-
Short-circuit breaking capacity and back-up fuses
lCS
Rated service short-circuit breaking capacity
lCU
Rated ultimate short-circuit breaking capacity
ICC
Prospective short-circuit current at installation location
Note: Maximum rated current of the back-up fuses if ICC > ICS
Type
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
230 V AC
ICU
ICS
kA
kA
gG, aM
A
400 V AC
ICS
ICU
kA
kA
gG, aM
A
440 V AC
ICS
ICU
kA
kA
gG, aM
A
500 V AC
ICS
ICU
kA
kA
gG, aM
A
690 V AC
ICS
ICU
kA
kA
gG, aM
A
No back-up fuse required up to ICC = 30 kA
No back-up fuse required up to ICC = 50 kA
25
16
10
10
10
25
16
15
15
10
80
80
125
125
125
25
16
10
10
10
25
16
15
15
10
80
80
125
125
125
10
6
6
6
6
6
3
3
3
10
6
6
6
6
6
6
6
6
25
25
63
63
63
63
125
125
125
10
6
6
6
6
4
3
3
3
10
6
6
6
6
4
4
4
4
25
25
63
63
63
63
125
125
125
5
2
2
2
2
2
2
2
2
5
2
2
2
2
2
2
2
2
25
25
40
50
50
63
80
100
100
MS116-10: No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
MS116-16: No need for back-up fuse in networks with a prospective current of up to 16 kA at 400 V.
With an approbiate 80 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
MS116-32: No need for back-up fuse in networks with a prospective current of up to 10 kA at 400 V.
2CDC131062C0201
2
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
2/8 | ABB
MS116, MS132, MO132, MS132-T
Technical data
Type
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-20
MS132-25
MS132-32
230 V AC
ICS
ICU
kA
kA
gG, aM
A
400 V AC
ICS
ICU
kA
kA
gG, aM
A
440 V AC
ICS
ICU
kA
kA
gG, aM
A
500 V AC
ICS
ICU
kA
kA
gG, aM
A
690 V AC
ICS
ICU
kA
kA
gG, aM
A
2
No back-up fuse required up to ICC = 100 kA
50
25
50
50
125
125
50
25
50
50
125
125
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
35
63
100
100
125
125
125
125
20
20
20
20
20
20
10
10
20
20
20
20
20
20
10
10
35
63
100
100
125
125
125
125
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
32
50
50
63
63
80
100
100
MS132-16: No need for back-up fuse in networks with a prospective current of up to 100 kA at 400 V.
MS132-32: No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 125 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
Type
MO132-0.16
MO132-0.25
MO132-0.4
MO132-0.63
MO132-1.0
MO132-1.6
MO132-2.5
MO132-4.0
MO132-6.3
MO132-10
MO132-12
MO132-16
MO132-20
MO132-25
MO132-32
230 V AC
ICS
ICU
kA
kA
gG, aM
A
400 V AC
ICS
ICU
kA
kA
gG, aM
A
440 V AC
ICS
ICU
kA
kA
gG, aM
A
500 V AC
ICS
ICU
kA
kA
gG, aM
A
690 V AC
ICS
ICU
kA
kA
gG, aM
A
125
125
20
20
20
20
20
20
10
10
35
63
100
100
125
125
125
125
20
20
20
20
20
20
10
10
35
63
100
100
125
125
125
125
3
3
3
3
3
3
3
3
32
50
50
63
63
80
100
100
No back-up fuse required up to ICC = 100 kA
50
25
50
50
125
125
50
25
50
50
20
20
20
20
20
20
10
10
20
20
20
20
20
20
10
10
3
3
3
3
3
3
3
3
MO132-20: No need for back-up fuse in networks with a prospective current of up to 100 kA at 400 V.
MO132-32: No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 125 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
MS132-0.16T
MS132-0.25T
MS132-0.4T
MS132-0.63T
MS132-1.0T
MS132-1.6T
MS132-2.5T
MS132-4.0T
MS132-6.3T
MS132-10T
MS132-12T
MS132-16T
MS132-20T
MS132-25T
230 V AC
ICS
ICU
kA
kA
gG, aM
A
400 V AC
ICS
ICU
kA
kA
gG, aM
A
440 V AC
ICS
ICU
kA
kA
gG, aM
A
500 V AC
ICS
ICU
kA
kA
gG, aM
A
690 V AC
ICS
ICU
kA
kA
gG, aM
A
125
30
30
30
30
30
30
30
35
63
100
100
125
125
125
20
20
20
20
20
20
10
35
63
100
100
125
125
125
3
3
3
3
3
3
3
32
50
50
63
63
80
100
No back-up fuse required up to ICC = 100 kA
50
50
125
50
50
30
30
30
30
30
30
30
20
20
20
20
20
20
10
3
3
3
3
3
3
3
ABB | 2/9
2CDC131062C0201
Type
MS116, MS132, MO132, MS132-T
Technical data
Main circuit – Utilization characteristics according to UL/CSA
MS116
MS132
UL 60947-1, UL60947-4-1
600 V AC
See table "UL – Manual motor controller"
125 % FLA
See table "Motor rating, three phase"
See table "Motor rating, three phase"
See table "Motor rating, three phase"
MO132
MS132-T
-
MS116
x
-
MO132
x
-
MS132-T
-
UL/CSA functions
Type
Manual motor controller
Manual self-protected combination motor controller
Self-protected combination motor controller
Tap conductor protector
MS132
x
x
with AF contactor
x
UL – Manual motor controller
Type
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32
1)
Maximum fuse type K5 o. RK5 Maximum short-circuit current
per UL/NEC
for motor disconnect1)
480 V / 600 V
480 V
A
kA
100
30
100
30
100
30
100
30
100
30
100
30
100
30
100
18
100
18
100
18
100
18
100
18
100
18
100
18
100
18
600 V
kA
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
for group installation
480 V
kA
30
30
30
30
30
30
30
18
18
18
18
18
18
18
18
600 V
kA
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Suitable as motor disconnect only when provided with padlock SA1 or SA3...
2CDC131062C0201
2
Type
Standards
Maximum operational voltage
Manual motor controller ratings
Trip rating
Motor ratings
Horse power
Full load amps (FLA)
Locked rotor amps (LRA)
2/10 | ABB
MS116, MS132, MO132, MS132-T
Technical data
Maximum short-circuit current
for motor disconnect
for group installation
kA
kA
kA
kA
for self-protected combination motor controller
(type E) in combination with
feeder block S1-M3-xx
480Y / 277
600Y / 347 V
V
kA
kA
65
65
65
65
65
65
65
65
65
65
30
30
30
30
30
47
47
47
47
47
47
47
18
18
18
18
18
18
18
18
65
65
65
65
65
65
65
65
65
65
30
30
30
30
30
47
47
47
47
47
47
47
30
30
30
30
30
30
30
30
65
65
65
65
65
65
65
65
65
65
30
30
30
30
30
480 V
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-20
MS132-25
MS132-32
Type
MO132-0.16
MO132-0.25
MO132-0.4
MO132-0.63
MO132-1.0
MO132-1.6
MO132-2.5
MO132-4.0
MO132-6.3
MO132-10
MO132-12
MO132-16
MO132-20
MO132-25
MO132-32
600 V
480 V
600 V
Circuit breaker or class R fuse per UL/NEC
480 V / 600 V
with minimum interrupting rating of 35,000 rms
symmetrical amperes
47
47
47
47
47
47
47
47
18
18
-
for self-protected combination motor
controller (type F)
for tap conductor
protection
480Y / 277
V
kA
600Y / 347 V Minimum
contactor
kA
size
480 V
kA
kA
65
65
65
65
65
65
65
65
65
65
30
30
30
30
30
47
47
47
47
47
47
47
47
47
47
-
65
65
65
65
65
65
65
65
65
65
30
30
30
30
30
47
47
47
47
47
47
47
47
18
18
18
18
18
18
18
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...AF38
AF26...
AF38, AF40
2
600 V
Maximum short-circuit current rating
480 V
kA
600 V
kA
30
18
30
30
30
30
18
18
18
18
30
30
30
30
30
30
30
30
30
30
18
18
18
18
18
18
18
18
18
18
2CDC131062C0201
Type
ABB | 2/11
MS116, MS132, MO132, MS132-T
Technical data
General technical data
MS116
3
Yes
Yes
MS132
3
Yes
Yes
MO132
3
No
Yes
MS132-T
3
Yes
Yes
-25 ... +55 °C
-25 ... +70 °C
0 ... +40 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
5g / 3 ... 150 Hz
-25 ... +60 °C
-25 ... +70 °C
0 ... +40 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
5g / 3 ... 150 Hz
-25 ... +60 °C
-50 ... +80 °C
2000 m
25g / 11 ms
5g / 3 ... 150 Hz
-25 ... +60 °C
-25 ... +70 °C
0 ... +40 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
5g / 3 ... 150 Hz
Mounting position
Position 1-6 (optional for
single mounting)
DIN-rail (EN 60715)
On request
0 mm
150 mm
0 mm
> 1.5 mm
75 mm
IP20
IP20
Position 1-6 (optional for
single mounting)
DIN-rail (EN 60715)
On request
0 mm
150 mm
0 mm
> 1.5 mm
75 mm
IP20
IP20
Position 1-6 (optional for
single mounting)
DIN-rail (EN 60715)
On request
0 mm
150 mm
0 mm
> 1.5 mm
75 mm
IP20
IP20
Position 1-6 (optional for
single mounting)
DIN-rail (EN 60715)
0 mm
150 mm
0 mm
> 1.5 mm
75 mm
IP20
IP20
Mounting
Group mounting
Minimum distance to other
units same type
Minimum distance to
electrical conductive board
Degree of protection
Horizontal
Vertical
Horizontal, up to 400 V
Horizontal, up to 690 V
Vertical
Housing
Main circuit terminals
2CDC131062C0201
2
Type
Pollution degree
Phase loss sensitivity
Disconnect function acc. to IEC/EN 60947-2
Ambient air temperature
Operation
Open - compensated
Open
Enclosed (IB132)
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
2/12 | ABB
MS116, MS132, MO132, MS132-T
Technical data
Connecting characteristics
Main circuit
Type
Connecting capacity
Rigid
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
MS116 ≤ 16 A
MS116 ≥ 20 A
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 16-12
AWG 16-12
9 mm
0.8 ... 1.2 Nm / 10 … 12 Ib.in
M3.5 (Pozidriv 2 / 5.5 mm)
2.5 ... 6 mm²
1 ... 6 mm²
1 ... 6 mm²
1 ... 6 mm²
AWG 12-8
AWG 12-8
10 mm
2.0 Nm / 18 Ib.in
M4 (Pozidriv 2 / 6.5 mm)
MS132-0.16 … MS132-10
MS132-12 … MS132-32
1 or 2 x 1 ... 4 mm²
Flexible with ferrule
Flexible with insulated ferrule
Flexible
1 or 2 x 0.75 ... 2.5 mm²
1 or 2 x 0.75 ... 2.5 mm²
1 or 2 x 0.75 ... 2.5 mm²
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 or 2 x AWG 16-12
1 or 2 x AWG 16-12
9 mm
0.8 ... 1.2 Nm / 10 … 12 Ib.in
M3.5 (Pozidriv 2)
Stripping length
Tightening torque
Recommended screw driver
Main circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stripping length
Tightening torque
Recommended screw driver
MS132-T ≤ 10 A
1 or 2 x 1 ... 4 mm²
1 or 2 x 0.75 ... 2.5 mm²
1 or 2 x 0.75 ... 2.5 mm²
1 or 2 x 0.75 ... 2.5 mm²
9 mm
0.8 ... 1.2 Nm / 10 … 12 Ib.in
M3.5 (Pozidriv 2 / 5.5 mm)
2
1 ... 2.5 mm²
2.5 ... 6 mm²
0.75 ... 6 mm²
0.75 ... 6 mm²
1 ... 2.5 mm²
2.5 ... 6 mm²
AWG 16-8
AWG 16-8
10 mm
2.0 Nm / 18 Ib.in
M4 (Pozidriv 2)
MS132-T ≥ 12 A
1/2 x 1 ... 2.5 mm²
1/2 x 2.5 ... 6 mm²
1/2 x 0.75 ... 6 mm²
1/2 x 0.75 ... 6 mm²
1/2 x 1 ... 2.5 mm²
1/2 x 2.5 ... 6 mm²
10 mm
2.0 Nm / 18 Ib.in
M4 (Pozidriv 2 / 6.5 mm)
2CDC131062C0201
Main circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
ABB | 2/13
MS116, MS132, MO132, MS132-T
Main accessories
Manual motor starter with accessories (MS116, MO132)
HK1
2
SK1
HK1
MS116
MO132
HK1
AA1
2CDC246001F0013
HKF1
UA1
Manual motor starter with accessories (MS132) and circuit breaker for transformer protection (MS132-T)
HK1
SK1
HK1
HK1
MS132
MS132-T
SK1
HK1
CK1
CK1
AA1
2/14 | ABB
2CDC131050C0201
UA1
1SBC500311F0000
HKF1
1SBC101208F0014
MS116, MS132, MO132, MS132-T
Main accessories
HKF1-11
Description
MMS and MS132-T can be equipped with auxiliary contacts for lateral/front mounting, signaling contact
for lateral mounting, undervoltage release and shunt trips. Two different signaling contacts are available.
The accessories can be fitted wiring free and without tools. A variety of combinations is possible as
required for the application. The auxiliary contacts change position with the main contacts. The signaling
contact SK signals tripping regardless if it was caused by short-circuit or overload. The signaling contact
CK signals tripping in case it was caused by short-circuit. Undervoltage release are used for remote
tripping of the manual motor starter especially for emergency stop circuits. Shunt trips release the MMS
used for remote tripping.
2
Ordering details
1SBC101209F0014
Suitable for
HK1-11
Auxiliary Auxiliary Description
contacts contacts
N.O.
N.C.
Type
Auxiliary contacts – mountable on the front
MS116, MS132, 1
1
MO132,
2
0
MS132-T
1SBC101210F0014
Auxiliary contacts – mountable on the right
MS116, MS132, 1
1
max. 2 pieces
MO132,
2
0
max. 2 pieces
MS132-T
0
2
max. 2 pieces
2
0
with lead contacts
1SBC101286F0014
SK1-11
Signaling contacts – mountable on the right
MS116, MS132, 1
1
for tripped alarm,
MO132,
max. 2 pieces
MS132-T
2
0
for tripped alarm,
max. 2 pieces
0
2
for tripped alarm,
max. 2 pieces
MS132,
1
1
for short-circuit alarm,
MS132-T
max. 2 pieces
2
0
for short-circuit alarm,
max. 2 pieces
0
2
for short-circuit alarm,
max. 2 pieces
Order code
Pkg
qty
Weight
(1 pce)
pce
kg
HKF1-11
HKF1-20
1SAM201901R1001
1SAM201901R1002
10
10
0.015
0.015
HK1-11
HK1-20
HK1-02
HK1-20L
1SAM201902R1001
1SAM201902R1002
1SAM201902R1003
1SAM201902R1004
2
2
2
2
0.035
0.035
0.035
0.035
SK1-11
1SAM201903R1001
2
0.035
SK1-20
1SAM201903R1002
2
0.035
SK1-02
1SAM201903R1003
2
0.035
CK1-11
1SAM301901R1001
2
0.035
CK1-20
1SAM301901R1002
2
0.035
CK1-02
1SAM301901R1003
2
0.035
CK1-11
27.8 1.09"
42.3 1.67"
68.8
2.71"
72 2.83"
3.54"
2CDC131050C0201
5.5 0.22"
2CDC242001F0012
9 0.35"
90
45 1.77"
mm, inches
42.1 1.66"
Main dimensions
HK1
ABB | 2/15
MS116, MS132, MO132, MS132-T
Main accessories
Ordering details
Suitable for
Rated control supply voltage
50 Hz
V AC
1SBC101211F0014
2
1SBC101212F0014
AA1-24
Type
Order code
60 Hz
V AC
Shunt trips – mountable on the left
MS116, MS132,
20 ... 24
MO132, MS132-T
110
200 ... 240
350 ... 415
20 ... 24
110
200 ... 240
350 ... 415
Undervoltage releases – mountable on the left
MS116, MS132,
20
24
MO132, MS132-T
24
48
60
110
120
208
230
240
400
415
480
575
Pkg
qty
Weight
(1 pce)
pce
kg
AA1-24
AA1-110
AA1-230
AA1-400
1SAM201910R1001
1SAM201910R1002
1SAM201910R1003
1SAM201910R1004
1
1
1
1
0.100
0.100
0.100
0.100
UA1-20
UA1-24
UA1-48
UA1-60
UA1-110
UA1-208
UA1-230
UA1-400
UA1-415
UA1-575
1SAM201904R1010
1SAM201904R1001
1SAM201904R1002
1SAM201904R1003
1SAM201904R1004
1SAM201904R1008
1SAM201904R1005
1SAM201904R1006
1SAM201904R1007
1SAM201904R1009
1
1
1
1
1
1
1
1
1
1
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
UA1-24
AA1, UA1
2/16 | ABB
5.5 0.22"
18 0.71"
2CDC131050C0201
43.5 1.71"
70 2.76"
2CDC242002F0012
1.77"
45
mm, inches
37 1.46"
3.54"
90
Main dimensions
MS116, MS132, MO132, MS132-T
Main accessories
General technical data
Type
Standards
Rated operational voltage Ue
Conventional free-air thermal current Ith
Rated frequency
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Pollution degree
Ambient air temperature
HK1
SK1
IEC/EN 60947-2, IEC/EN 60947-4-1, IEC/EN 60947-1
690 V AC / 600 DC
6A
50/60 Hz
6 kV
690 V AC
3
-25 ... +70 °C
-50 ... +80 °C
25g / 11 ms
5g / 3 ... 150 Hz
Operation
Storage
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
HKF1
250 V AC / 250 V DC
5A
2
250 V AC
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
24 V, 120 V
6A
3A
240 V
4A
1.5 A
400 V
3A
-
440 V, 690 V
1A
-
24 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
2A
1A
125 V
0.55 A
0.27 A
250 V
0.27 A
0.11 A
440 V, 600 V
0.15 A
-
17 V / 5 mA
Minimum switching capacity
Short-circuit protective device
N.C., 95-96
10 A Type gG
N.O., 97-98
10 A Type gG
Duty time
100 %
Mounting
Right side of MMS / MS132-T
Mounting positions
1-6
Mechanical durability
50000 cycles
-
Electrical durability
50000 cycles
-
Front of MMS / MS132-T
Connecting characteristics
HK1
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 ... 1.5 mm²
0.75 ... 1.5 mm²
0.75 ... 1.5 mm²
0.75 ... 1.5 mm²
AWG 16-14
AWG 16-14
8 mm
0.8 ... 1.2 Nm / 7 Ib.in
M3 (Pozidriv 2)
SK1
HKF1
1 ... 2.5 mm²
2CDC131050C0201
Auxiliary circuit
Type
Connecting capacity
ABB | 2/17
MS116, MS132, MO132, MS132-T
Main accessories
General technical data
Type
Standards
Rated control supply voltage
2
Rated frequency
Operating voltage
Tripping
Coil operating voltage
Pull-in
Power consumption
Holding
AC
DC
AC
DC
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Pollution degree
UA1
AA1
IEC/EN 60947-1,IEC/EN 60947-4-1,UL 60947-1,UL 60947-4-1
see ordering details
AA1-24: 20-24 V 50/60 Hz; 20-70 V 50/60 Hz
KB = 5 s, 20-70 V DC KB = 5 s
AA1-100: 110 V 50/60 Hz; 110-200 V 50/60 Hz
KB = 5 s, 110-200 V DC KB = 5 s
AA1-230: 200-240 V 50/60 Hz, 200-350 V
50/60 Hz KB = 5 s, 200-350 V DC KB = 5 s
AA1-400: 350-415 V 50/60 Hz, 350-500 V
50/60 Hz KB = 5 s, 350-500 V DC KB = 5 s
see ordering details
50/60 Hz, DC
0.35 … 0.7 x Us
0.7 … 1.1 x Us
0.85 … 1.1 x Us
on request
on request
on request
on request
on request
on request
6 kV
6 kV
690 V
690 V
3
3
Operation
-25 …. +60 °C
-25 …. +60 °C
Storage
-50 …+80 °C
-50 …+80 °C
Resistance to shock acc. to IEC 60068-2-27
25g / 11 ms
25g / 11 ms
Resistance to vibrations acc. to IEC 60068-2-6
5g / 3 ... 150 Hz
5g / 3 ... 150 Hz
Mounting
left side of MMS / MS132-T
left side of MMS / MS132-T
Mounting positions
-
-
UA1
AA1
Ambient air temperature
Connecting characteristics
Auxiliary circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
0.75 ... 2.5 mm²
AWG 16-12
AWG 16-12
10 mm
0.8 ... 1.2 Nm / 7 Ib.in
M3 (Pozidriv 2)
2CDC131050C0201
Stripping length
Tightening torque
Recommended
screw driver
1 or 2 x
1 or 2 x
1x
2x
1 or 2 x
1 or 2 x
1 or 2 x
2/18 | ABB
MS116, MS132, MO132
Main accessories
Manual motor starter with three-phase busbar systems
S1-M2-25
S1-M3-35
PS1-..-65
PS1-..-100
2
S1-M1-25
BS1-3
Three-phase busbar up to 100 A
2CDC131050C0201
Three-phase busbar up to 65 A
2CDC242021F0013
SA1
2CDC242020F0013
PS1-..-65
ABB | 2/19
MS116, MS132, MO132, MS132-T
Main accessories
Description
2CDC241017F0010
Three-phase busbars ensure a quick and safe connection and are therefore a cost effective solution.
A variety of different three-phase busbars up to 100 A are in the assortment. Between 2 and 5 manual
motor starters with none, one or two lateral auxiliary contacts can be connected. Different three-phase
feeder terminals are available according to the application.
Phase connecting links and phase power infeed blocks are also available for single-phase applications.
2
2CDC241014F0010
1SBC101226F0014
PS1-3-1-100
1SBC101266F0014
S1-M1-25
2CDC241023F0013
S1-M2-25
Suitable for
Three-phase busbars
MS116,
65
MS132,
65
MO132
65
65
65
65
65
65
65
65
65
65
MS116,
100
MS132,
100
MO132
100
100
100
100
100
Suitable for
SA2
SK0108B91
Rated
operational
current
A
Rated
operational
current
A
Number of
MMS
2
3
4
5
2
3
4
5
2
3
4
5
3
4
5
3
4
5
3
2CDC241004F0014
2CDC241005S0014
2/20 | ABB
Order code
35
Flat
High
UL type E
and IEC
UL type E
and IEC
Pkg
qty
Weight
(1 pce)
pce
kg
PS1-2-0-65
PS1-3-0-65
PS1-4-0-65
PS1-5-0-65
PS1-2-1-65
PS1-3-1-65
PS1-4-1-65
PS1-5-1-65
PS1-2-2-65
PS1-3-2-65
PS1-4-2-65
PS1-5-2-65
PS1-3-0-100
PS1-4-0-100
PS1-5-0-100
PS1-3-1-100
PS1-4-1-100
PS1-5-1-100
PS1-3-2-100
1SAM201906R1102
1SAM201906R1103
1SAM201906R1104
1SAM201906R1105
1SAM201906R1112
1SAM201906R1113
1SAM201906R1114
1SAM201906R1115
1SAM201906R1122
1SAM201906R1123
1SAM201906R1124
1SAM201906R1125
1SAM201916R1103
1SAM201916R1104
1SAM201916R1105
1SAM201916R1113
1SAM201916R1114
1SAM201916R1115
1SAM201916R1123
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.034
0.055
0.077
0.098
0.036
0.060
0.087
0.108
0.040
0.067
0.095
0.122
0.084
0.117
0.154
0.094
0.134
0.172
0.105
Type
Order code
Pkg
qty
Weight
(1 pce)
pce
kg
S1-M1-25
S1-M2-25
S1-M3-25
1SAM201907R1101
1SAM201907R1102
1SAM201907R1103
10
10
10
0.038
0.051
0.042
S1-M3-35
1SAM201913R1103
10
0.060
Weight
(1 pce)
kg
0.003
0.020
0.020
0.003
0.050
0.009
0.013
Suitable for
Description
Type
Order code
MS116, MS132, MO132
MS116, MS132, MO132,
MS132-T
Protection cover for busbars
Screw fixing kit
Padlock + two keys
Lock handle
Lock handle box SA1/SA2
BS1-3
FS116
SA2
SA1
SA3
1SAM201908R1001
1SAM201909R1001
GJF1101903R0002
GJF1101903R0001
GJF1101903R0003
Pkg
qty
pce
50
1
10
10
10
PB1-1-32
S1-PB1-25
1SAM201914R1001
1SAM201914R1002
1
1
MS116
S1-PB1-25
Type
mm²
SA1
PB1-1-32
0
0
0
0
1
1
1
1
2
2
2
2
0
0
0
1
1
1
2
Rated cross Mounting
section
form
Three-phase feeder terminals
MS116,
65
25
MS132,
65
25
MO132
65
25
100
Number of
lateral aux.
Accessories for single-phase connection
MS116, MS132, MO132,
Phase connecting link
MS132-T
Phase power infeed block
2CDC131050C0201
Ordering details
PS1-2-0-65
MS116, MS132, MO132
Main accessories
General technical data
Type
Standards
Rated operational voltage Ue
Rated operational current Ie
Rated frequency
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Pollution degree
Cross-section
Ambient air temperature
Operation
Storage
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
PS1-xxx-65
PS1-xxx-100
IEC/EN 60947-4-1, IEC/EN 60947-1
690 V
65 A
100 A
50/60 Hz
6 kV
690 V AC
3
10 mm²
16 mm²
-25 ... +70 °C
-50 ... +80 °C
25g / 11 ms
5g / 3 ... 150 Hz
S1-Mx-25
S1-Mx-35
65 A
100 A
25 mm²
35 mm²
S1-Mx-25
S1-Mx-35
6 ... 25 mm²
6 ... 16 mm²
6 ... 16 mm²
6 ... 16 mm²
AWG 10-4
AWG 10-6
10 mm
2.5 Nm / 22 Ib.in
PZ2 (6 mm)
10 ... 35 mm²
10 ... 35 mm²
10 ... 35 mm²
10 ... 35 mm²
AWG 8-2
AWG 8-2
12 mm
4.5 Nm / 40 Ib.in
Hexagon SW4
2
Main circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1x
1x
1x
1x
1x
1x
2CDC131050C0201
Electrical connection
ABB | 2/21
MS116, MS132, MO132
Main accessories
Description
2CDC241004F0010
2
IB132 are IP65 enclosures for single MMS installation. Additional mounting of auxiliary and signaling
contacts, shunt trips and undervoltage release is possible. The handle is lockable in OFF position. For
detailed specification see installation instruction.
DMS132 are IP65 door mounting kits for MMS installation in any enclosure. Additional mounting of
auxiliary, signaling, shunt trips and undervoltage release is possible. The handle is lockable in OFF
position. For detailed specification see installation instruction.
Ordering details
Suitable for
2CDC241003F0010
IB132-Y
2CDC241002F0010
IB132-G
Description
Color
Type
Order code
Pkg
qty
Weight
(1 pce)
pce
kg
IP65 enclosures (UL: Type 12)
MS116, MS132,
Padlockable max. Yellow/red
MO132
3 padlocks with
Grey/black
bail diameter 4 ...
6.5 mm
IB132-Y
IB132-G
1SAM201911R1011
1SAM201911R1010
1
1
0.370
0.370
IP65 door mounting kits (UL: Type 12)
MS116, MS132,
Padlockable max. Yellow/red
MO132
3 padlocks with
Grey/black
bail diameter 4 ...
6.5 mm
DMS132-Y
DMS132-G
1SAM201912R1011
1SAM201912R1010
1
1
0.170
0.170
Indication I-O-T and ON-OFF-T
Please check for further equipment chapter General accessories.
2CDC241001F0010
DMS132-Y
DMS132-G
Main dimensions
mm, inches
118 4.65"
119 4.69"
174 6.85"
2CDC242011F0011
0
OFF
194 7.64"
183 7.2"
I ON
IB132
135.7 5.34"
92 3.62"
24 .94"
116.15 4.57"
DMS132
2/22 | ABB
2CDC131050C0201
0
OFF
2CDC242012F0011
121 4.76"
I ON
MS450, MS495, MS497 manual motor starters
22 to 100 A – with thermal and electromagnetic protection
2CDC241004F0009
Description
MS450-40
Manual motor starters (MMS) are protection devices for the main circuit. They combine motor control and
protection in a single device. MMS are used mainly to switch motors manually ON/OFF and protect them
and the installation fuse-less against short-circuit, overload and phase failures. Fuse-less protection with
a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by
switching off the motor within milliseconds.
Further features are the build-in disconnect function, temperature compensation, trip-free mechanism
and a rotary handle with a clear switch position indication. The manual motor starter is suitable for threeand single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary
contacts, signalling contacts, undervoltage releases, shunt trips, three-phase busbars, power in-feed
blocks are available as accessory.
2
Ordering details
1SBC101184F0014
Rated
Setting
operational range
power
400 V
AC-3
kW
A
2CDC241020F0011
MS495-40
Short-circuit
breaking
capacity ICS at
400 V AC
Rated instantaneous shortcircuit current
setting li
kA
A
Type
Order code
Weight
(1 pce)
kg
MS450 manual motor starters
18.5
28.0 … 40.0 25
22
36.0 … 45.0 25
22
40.0 … 50.0 25
520.00
585.00
650.00
MS450-40
MS450-45
MS450-50
1SAM450000R1005
1SAM450000R1006
1SAM450000R1007
1.047
1.039
1.027
MS495 manual motor starters
30
45.0 … 63.0 25
37
57.0 … 75.0 25
45
70.0 … 90.0 25
55
80.0 … 100.0 25
819.00
975.00
1170.00
1235.00
MS495-63
MS495-75
MS495-90
MS495-100
1SAM550000R1007
1SAM550000R1008
1SAM550000R1009
1SAM550000R1010
2.247
2.253
2.280
2.295
MS497 manual motor starters
15
22.0 … 32.0 50
18.5
28.0 … 40.0 50
22
36.0 … 50.0 50
30
45.0 … 63.0 50
37
57.0 … 75.0 50
45
70.0 … 90.0 50
55
80.0 … 100.0 50
416.00
520.00
650.00
819.00
975.00
1170.00
1235.00
MS497-32
MS497-40
MS497-50
MS497-63
MS497-75
MS497-90
MS497-100
1SAM580000R1004
1SAM580000R1005
1SAM580000R1006
1SAM580000R1007
1SAM580000R1008
1SAM580000R1009
1SAM580000R1010
2.222
2.203
2.230
2.255
2.266
2.268
2.275
MS497-100
MS450
1.18"
55
2.17"
12
8
5
23
0.47"
0.20"
0.32"
109 4.29"
127 5.0"
132 5.2"
144 5.67"
0.91"
8
0.31"
30 1.18"
70
2.56"
5
0.20"
7
0.28"
132 5.20"
153 6.02"
169 6.65"
2CDC242014F0011
45 1.77"
30
0.79"
MS495, MS497
ABB | 2/23
2CDC131042C0201
20
165 6.50"
155 6.10"
0.39"
2CDC242013F0011
10
mm, inches
85 3.35"
130 5.12"
140 5.51"
0.67"
125 4.92"
17
45 1.77"
116 4.57"
150 5.91"
Main dimensions
MS450, MS495, MS497 manual motor starters
Technical data
Main circuit – Utilization characteristics according to IEC/EN
MS450, MS495, MS497
IEC/EN 60947–2, IEC/EN 60947-4-1, IEC/EN 60947-1
690 V AC / 450 V DC
50/60 Hz
10
3
100 %
50000 cycles
25000 cycles
6 kV
690 V AC
See ordering details
See ordering details
See table "Short-circuit breaking capacity and back-up fuses"
See table "Short-circuit breaking capacity and back-up fuses"
Short-circuit breaking capacity and back-up fuses
lCS
Rated service short-circuit breaking capacity
lCU
Rated ultimate short-circuit breaking capacity
ICC
Prospective short-circuit current at installation location
Note: Maximum rated current of the back-up fuses if ICC > ICS
Type
240 V AC
ICU
ICS
kA
kA
gG, aM
A
Short-circuit protection MS450
MS450-40
No back-up fuse required up to
MS450-45
ICC = 100 kA
MS450-50
MS450:
400 V AC
ICS
ICU
kA
kA
gG, aM
A
440 V AC
ICS
ICU
kA
kA
gG, aM
A
500 V AC
ICS
ICU
kA
kA
gG, aM
A
690 V AC
ICS
ICU
kA
kA
gG, aM
A
25
25
25
160
160
160
15
15
15
125
125
125
5
5
5
100
100
100
2
2
2
4
4
4
63
63
80
125
125
160
160
160
160
3
3
3
3
3
3
6
6
6
5
5
5
63
80
80
100
125
125
100
160
160
160
160
160
160
7
6
5
4
3
3
3
12
12
10
7.5
6
6
6
63
80
100
100
125
160
160
50
50
50
50
50
50
10
10
10
No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 160 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
Short-circuit protection MS495
MS495-40
MS495-50
MS495-63
No back-up fuse required up to
ICC = 100 kA
MS495-75
MS495-90
MS495-100
25
25
25
25
25
25
50
50
50
50
50
50
125
125
160
160
160
160
20
20
20
20
20
20
50
50
50
50
50
50
125
125
160
160
160
160
6
6
6
6
6
6
12
12
12
8
8
8
MS495-40: No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 125 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
MS495-100: No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 160 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
Short-circuit protection MS497
MS497-32
MS497-40
MS497-50
No back-up fuse required up to
MS497-63
ICC = 100 kA
MS497-75
MS497-90
MS497-100
50
50
50
50
50
50
50
100
100
100
100
100
100
100
50
50
No back50
up fuse
required 50
up to ICC 50
= 100 kA
50
50
100
100
100
70
70
70
70
No back-up
fuse required
up to
ICC = 100 kA
200
200
200
200
11
9
7.5
7.5
5
5
5
22
18
15
15
10
10
10
MS497-32: No need for back-up fuse in networks with a prospective current of up to 100 kA at 440 V.
MS497-90: No need for back-up fuse in networks with a prospective current of up to 70 kA at 440 V.
With an approbiate 200 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
2/24 | ABB
2CDC131042C0201
2
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Mechanical durability
Electrical durability
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Rated operational current Ie
Rated instantaneous short-circuit current setting Ii
Rated service short-circuit breaking capacity Ics
Rated ultimate short-circuit breaking capacity Icu
MS450, MS495, MS497 manual motor starters
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Manual motor controller ratings
Trip rating
Motor ratings
Horse power
Full load amps (FLA)
Locked rotor amps (LRA)
MS450, MS495, MS497
UL 508, CSA 22.2 No. 14
600 V AC
See table "UL 508 – Manual motor controller"
125 % FLA
See table "Motor rating, three phase"
See table "Motor rating, three phase"
See table "Motor rating, three phase"
2
Motor rating, three phase
hp
Horse power
FLA Full load amps
LRA Locked rotor amps
Type
General purpose rating
at max. 600 V AC
A
Full load amps
200 - 208 V AC
230 V AC
460 V AC
575 V AC
FLA
hp
hp
hp
hp
MS450-40
MS450-45
MS450-50
MS495-63
MS495-75
MS495-90
MS495-100
MS497-32
MS497-40
MS497-50
MS497-63
MS497-75
MS497-90
MS497-100
40
45
50
63
75
90
100
32
40
50
63
75
90
100
40
45
50
63
75
90
100
32
40
50
63
75
90
100
10
15
15
20
25
30
40
10
15
15
20
25
30
30
15
15
20
25
25
30
40
10
15
20
25
25
30
40
30
30
40
50
60
75
75
25
30
40
50
60
75
75
40
40
50
60
75
100
100
30
40
50
60
75
100
100
UL 508 – Manual motor controller
Type
MS450-40
MS450-45
MS450-50
MS495-63
MS495-75
MS495-90
MS495-100
MS497-32
MS497-40
MS497-50
MS497-63
MS497-75
MS497-90
MS497-100
Circuit breaker Max. circuit
or class R fuse breaker or
per UL/NEC
fuse per UL/
NEC
Maximum short-circuit current
for motor disconnect
for group installation
480/600 V
A
150
175
200
250
300
350
400
120
160
200
250
300
350
400
480 V
kA
65
65
65
65
65
65
65
65
65
65
65
65
65
65
480/600 V
A
350
350
350
500
500
500
500
500
500
500
500
500
500
500
600 V
kA
25
25
25
30
30
10
10
30
30
30
30
30
10
10
480 V
kA
65
65
65
65
65
65
65
65
65
65
65
65
65
65
600 V
kA
25
25
25
30
30
10
10
30
30
30
30
30
10
10
for tap
conductor
for protection UL 508
480Y/277V
kA
65
65
65
65
65
65
65
65
65
65
65
65
-
600Y/347V
kA
25
25
25
30
30
30
30
30
30
30
-
Type E *
Type E
480Y/277V
kA
65
65
65
65
65
65
65
65
65
65
65
65
65
65
600Y/347V
kA
25
25
25
30
30
30
30
30
30
30
-
2CDC131042C0201
* only with use DX495
ABB | 2/25
MS450, MS495, MS497 manual motor starters
Technical data
General technical data
MS450
3
Yes
Yes
-20 ... +60 °C
-20 ... +70 °C
-20 ... +35 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
2g / 5-150 Hz
Position 1-6 (optional for single
DIN-rail 35 mm (EN 60715)
0 mm
50 mm
10 mm
50 mm
IP20
IP00
MS495
MS497
mounting)
DIN-rail 15 mm / 75 mm (EN 60715)
0 mm
50 mm
70 mm
110 mm
150 mm
10 mm
30 mm
50 mm
70 mm
110 mm
150 mm
-
Connecting characteristics
Main circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1x
2x
1x
2x
1x
2x
1x
2x
MS450
MS495
MS497
0.75 ... 16 mm²
0.75 ... 35 mm²
0.75 ... 25 mm²
0.75 ... 35 mm²
0.75 ... 25 mm²
AWG 18-2
AWG 18-2
AWG 18-2
AWG 18-2
13 mm
3 - 4.5 Nm / 27 … 40 Ib.in
Pozidriv 2
2.5 ... 16 mm²
10 ... 70 mm²
10 ... 50 mm²
10 ... 70 mm²
10 ... 50 mm²
AWG 10-2/0
AWG 10-1/0
AWG 10-2/0
AWG 10-1/0
17 mm
4 - 6 Nm / 35 - 53 Ib.in
Hexagon 4
2.5 ... 16 mm²
10 ... 70 mm²
10 ... 50 mm²
10 ... 70 mm²
10 ... 50 mm²
AWG 10-2/0
AWG 10-1/0
AWG 10-2/0
AWG 10-1/0
17 mm
4 - 6 Nm / 35 - 53 Ib.in
Hexagon 4
2CDC131042C0201
2
Type
Pollution degree
Phase loss sensitivity
Disconnect function acc. to IEC/EN 60947-2
Ambient air temperature
Operation
Open - compensated
Open
Enclosed
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Minimum distance to other Horizontal
units same type
Vertical - up to 240 V
Vertical - up to 440 V
Vertical - up to 500 V
Vertical - up to 690 V
Vertical
Minimum distance to
Horizontal
electrical conductive board Horizontal - up to 500 V
Horizontal - up to 690 V
Vertical - up to 240 V
Vertical - up to 440 V
Vertical - up to 500 V
Vertical - up to 690 V
Vertical
Degree of protection
Housing
Main circuit terminals
2/26 | ABB
MO450, MO495, MO496 manual motor starters magnetic only
32 to 100 A – with electromagnetic protection
Description
ST02501
The manual motor starter magnetic only is used to manually switch on and off motors and to protect them
reliably and without the need for a fuse from short-circuits.
Further features are the build-in disconnect function, trip-free mechanism and a rotary handle with a clear
switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase
applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling
contacts, undervoltage releases, shunt trips, three-phase busbars, power in-feed blocks are available as
accessory.
ST02601
MO450-40
2CDC241021F0011
MO495-75
2
Ordering details
Rated
operational
power
400 V
AC-31)
kW
Rated
Short-circuit
operational breaking
current
capacity ICS at
400 V AC
Rated instantaneous shortcircuit current
setting li
A
A
kA
Type
Order code
Weight
(1 pce)
kg
MO450 manual motor starter magnetic only
18.5
40
25
520.00
22
45
25
585.00
22
50
25
650.00
MO450-40
MO450-45
MO450-50
1SAM460000R1005
1SAM460000R1006
1SAM460000R1007
1.033
1.040
1.019
MO495 manual motor starter magnetic only
30
63
25
37
75
25
45
90
25
55
100
25
819.00
975.00
1170.00
1235.00
MO495-63
MO495-75
MO495-90
MO495-100
1SAM560000R1007
1SAM560000R1008
1SAM560000R1009
1SAM560000R1010
2.244
2.247
2.269
2.292
MO496 manual motor starter magnetic only
15
32
50
18.5
40
50
22
50
50
30
63
50
37
75
50
45
90
50
55
100
50
416.00
520.00
650.00
819.00
975.00
1170.00
1235.00
MO496-32
MO496-40
MO496-50
MO496-63
MO496-75
MO496-90
MO496-100
1SAM590000R1004
1SAM590000R1005
1SAM590000R1006
1SAM590000R1007
1SAM590000R1008
1SAM590000R1009
1SAM590000R1010
2.208
2.218
2.218
2.248
2.278
2.266
2.293
For overload protection of motors, an appropriate thermal or electronic overload relay must be used
1)
MO496-100
MO450
1.18"
55
2.17"
12
8
5
23
0.47"
0.20"
0.32"
109 4.29"
127 5.0"
132 5.2"
144 5.67"
0.91"
8
0.31"
30 1.18"
70
2.56"
5
0.20"
7
0.28"
132 5.20"
153 6.02"
169 6.65"
2CDC242016F0011
45 1.77"
30
0.79"
MO495, MO496
ABB | 2/27
2CDC131038C0201
20
165 6.50"
155 6.10"
0.39"
2CDC242015F0011
10
mm, inches
85 3.35"
130 5.12"
140 5.51"
0.67"
125 4.92"
17
45 1.77"
116 4.57"
150 5.91"
Main dimensions
MO450, MO495, MO496 manual motor starters magnetic only
Technical data
Main circuit – Utilization characteristics according to IEC/EN
MO450, MO495, MO496
IEC/EN 60947–2, IEC/EN 60947-4-1, IEC/EN 60947-1
690 V AC / 450 V DC
50/60 Hz
3
100 %
50000 cycles
25000 cycles
6 kV
690 V AC
See ordering details
See ordering details
See table "Short-circuit breaking capacity and back-up fuses"
See table "Short-circuit breaking capacity and back-up fuses"
Short-circuit breaking capacity and back-up fuses
lCS
Rated service short-circuit breaking capacity
lCU
Rated ultimate short-circuit breaking capacity
ICC
Prospective short-circuit current at installation location
Note: Maximum rated current of the back-up fuses if ICC > ICS
Type
240 V AC
ICU
ICS
kA
kA
gG, aM
A
Short-circuit protection MO450
MO450-40
No back-up fuse required up to
MO450-45
ICC = 100 kA
MO450-50
MO450:
400 V AC
ICS
ICU
kA
kA
gG, aM
A
440 V AC
ICS
ICU
kA
kA
gG, aM
A
500 V AC
ICS
ICU
kA
kA
gG, aM
A
690 V AC
ICS
ICU
kA
kA
gG, aM
A
25
25
25
160
160
160
15
15
15
125
125
125
5
5
5
100
100
100
2
2
2
4
4
4
63
63
80
160
160
160
160
3
3
3
3
6
5
5
5
80
100
125
125
100
160
160
160
160
160
160
7
6
5
4
3
3
3
12
12
10
7.5
6
6
6
63
80
100
100
125
160
160
50
50
50
50
50
50
10
10
10
No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 160 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
Short-circuit protection MO495
MO495-63
MO495-75
No back-up fuse required up to
ICC = 100 kA
MO495-90
MO495-100
25
25
25
25
50
50
50
50
160
160
160
160
20
20
20
20
50
50
50
50
160
160
160
160
6
6
6
6
12
8
8
8
MO495-100: No need for back-up fuse in networks with a prospective current of up to 50 kA at 400 V.
With an approbiate 160 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
Short-circuit protection MO496
MO496-32
MO496-40
MO496-50
No back-up fuse required up to
MO496-63
ICC = 100 kA
MO496-75
MO496-90
MO496-100
50
50
50
50
50
50
50
100
100
100
100
100
100
100
50
50
No back50
up fuse
required 50
up to ICC 50
= 100 kA
50
50
100
100
100
70
70
70
70
No back-up
fuse required
up to
ICC = 100 kA
200
200
200
200
11
9
7.5
7.5
5
5
5
22
18
15
15
10
10
10
MO496-32: No need for back-up fuse in networks with a prospective current of up to 100 kA at 440 V.
MO496-90: No need for back-up fuse in networks with a prospective current of up to 70 kA at 440 V.
With an approbiate 200 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
2CDC131038C0201
2
Type
Standards
Rated operational voltage Ue
Rated frequency
Number of poles
Duty time
Mechanical durability
Electrical durability
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Rated operational current Ie
Rated instantaneous short-circuit current setting Ii
Rated service short-circuit breaking capacity Ics
Rated ultimate short-circuit breaking capacity Icu
2/28 | ABB
MO450, MO495, MO496 manual motor starters magnetic only
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Manual motor controller ratings
Trip rating
Motor ratings
Horse power
Full load amps (FLA)
Locked rotor amps (LRA)
M0450, MO495, MO496
UL 508, CSA 22.2 No. 14
600 V AC
See table "UL 508 – Manual motor controller"
125 % FLA
See table "Motor rating, three phase"
See table "Motor rating, three phase"
See table "Motor rating, three phase"
2
Motor rating, three phase
hp
Horse power
FLA Full load amps
LRA Locked rotor amps
Type
General purpose rating
at max. 600 V AC
A
Full load amps
200 - 208 V AC
230 V AC
460 V AC
575 V AC
FLA
hp
hp
hp
hp
MO450-40
MO450-45
MO450-50
MO495-63
MO495-75
MO495-90
MO495-100
MO496-32
MO496-40
MO496-50
MO496-63
MO496-75
MO496-90
MO496-100
40
45
50
63
75
90
100
32
40
50
63
75
90
100
40
45
50
63
75
90
100
32
40
50
63
75
90
100
10
15
15
20
25
30
40
10
15
15
20
25
30
30
15
15
20
25
25
30
40
10
15
20
25
25
30
40
30
30
40
50
60
75
75
25
30
40
50
60
75
75
40
40
50
60
75
100
100
30
40
50
60
75
100
100
for group installation
480 V
kA
65
65
65
65
65
65
65
65
65
65
65
65
65
65
600 V
kA
25
25
25
30
30
30
10
30
30
30
30
30
10
10
UL 508 – Manual motor controller
Type
MO450-40
MO450-45
MO450-50
MO495-63
MO495-75
MO495-90
MO495-100
MO496-32
MO496-40
MO496-50
MO496-63
MO496-75
MO496-90
MO496-100
Circuit breaker or class R Max. circuit breaker or
fuse per UL/NEC
fuse per UL/NEC
480/600 V
A
150
175
200
60
250
300
350
120
160
200
250
300
350
400
480/600 V
A
500
500
500
500
500
500
500
500
500
500
500
Maximum short-circuit current
for motor disconnect
480 V
kA
65
65
65
65
65
65
65
65
65
65
65
65
65
65
600 V
kA
25
25
25
30
30
30
10
30
30
30
30
30
10
10
2CDC131038C0201
* only with use DX495
ABB | 2/29
MO450, MO495, MO496 manual motor starters magnetic only
Technical data
General technical data
MO450
3
No
Yes
MO495
MO496
-20 ... +60 °C
-20 ... +70 °C (above 60° C, current derating)
-20 ... +35 °C
-50 ... +80 °C
2000 m
25g / 11 ms
2g / 5-150 Hz
Position 1-6 (optional for single mounting)
DIN-rail 35 mm (EN 60715)
DIN-rail 15 mm / 75 mm (EN 60715)
0 mm
0 mm
50 mm
70 mm
110 mm
150 mm
50 mm
10 mm
10 mm
30 mm
50 mm
70 mm
110 mm
150 mm
50 mm
IP20
IP20
Connecting characteristics
Main circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1x
2x
1x
2x
1x
2x
1x
2x
MO450
MO495
MO496
0.75 ... 16 mm²
0.75 ... 35 mm²
0.75 ... 25 mm²
0.75 ... 35 mm²
0.75 ... 25 mm²
AWG 18-2
AWG 18-2
AWG 18-2
AWG 18-2
13 mm
3 - 4.5 Nm / 27 … 40 Ib.in
Pozidriv 2
2.5 ... 16 mm²
10 ... 70 mm²
10 ... 50 mm²
10 ... 70 mm²
10 ... 50 mm²
AWG 10-2/0
AWG 10-1/0
AWG 10-2/0
AWG 10-1/0
17 mm
4 - 6 Nm / 35 - 53 Ib.in
Hexagon 4
2.5 ... 16 mm²
10 ... 70 mm²
10 ... 50 mm²
10 ... 70 mm²
10 ... 50 mm²
AWG 10-2/0
AWG 10-1/0
AWG 10-2/0
AWG 10-1/0
17 mm
4 - 6 Nm / 35 - 53 Ib.in
Hexagon 4
2CDC131038C0201
2
Type
Pollution degree
Phase loss sensitivity
Disconnect function acc. to IEC/EN 60947-2
Ambient air temperature
Operation
Open - compensated
Open
Enclosed
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Minimum distance to other Horizontal
units same type
Vertical - up to 240 V
Vertical - up to 440 V
Vertical - up to 500 V
Vertical - up to 690 V
Vertical
Minimum distance to
Horizontal
electrical conductive board Horizontal - up to 500 V
Horizontal - up to 690 V
Vertical - up to 240 V
Vertical - up to 440 V
Vertical - up to 500 V
Vertical - up to 690 V
Vertical
Degree of protection
Housing
Main circuit terminals
2/30 | ABB
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
Manual motor starters MS45x and MS49x with accessories
2CDC242025F0011
2
Manual motor starters MO45x and MO49x with accessories
MO45x
2CDC131051C0201
2CDC242025F0011
MO49x
ABB | 2/31
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
2CDC241026F0011
Description
2
HK4-11
Manual motor starters can be equipped with auxiliary contacts for lateral/front mounting, signalling contact
for lateral mounting, undervoltage release and shunt trips. The accessories can be fitted wiring free and
without tools. A variety of combinations is possible as required for the application. The auxiliary contacts
change position with the main contacts. Undervoltage release are used for remote tripping of the manual
motor starter especially for emergency stop circuits. Shunt trips release the MMS used for remote tripping.
Ordering details
Suitable Auxiliary Auxiliary Description
for
concontacts
tacts
N.O.
N.C.
Type
Order code
Pkg
qty
Weight
(1 pce)
2CDC241022F0011
kg
HKS4-20
Auxiliary contacts – mountable on the front
MS45x, 1
1
MS49x,
Changeover
MO45x,
MO49x
HK4-11
HK4-W
1SAM401901R1001
1SAM401901R1002
10
10
0.017
0.015
Auxiliary contacts – mountable on the left
MS45x, 1
1
Max. 1 piece
MS49x, 2
0
Max. 1 piece
MO45x,
0
2
Max. 1 piece
MO49x
HKS4-11
HKS4-20
HKS4-02
1SAM401902R1001
1SAM401902R1002
1SAM401902R1003
2
2
2
0.045
0.045
0.045
SK4-11
1SAM401904R1001
1
0.093
Type
Order code
Pkg
qty
Weight
(1 pce)
2CDC241024F0011
Signalling contacts – mountable on the left
MS45x, 2
2
Separate signalling acc.
MS49x,
UL508E 1 N.O. + 1 N.C.
MO45x,
for short circuit alarm and
MO49x
1 N.O. + 1 N.C. for tripped
alarm, max. 1x SK4-11 +
1 x HKS4-xx
SK4-11
Suitable Rated control supply
for
voltage
2CDC241023F0011
V
Hz
kg
Shunt trip units – mountable on the right
MS45x, 20 ... 24
50/60
MS49x, 90 ... 110
50/60
MO45x,
200 ... 240
50/60
MO49x
350 ... 415
50/60
AA4-24
AA4-110
AA4-230
AA4-400
1SAM401907R1001
1SAM401907R1002
1SAM401907R1003
1SAM401907R1004
1
1
1
1
0.135
0.135
0.128
0.125
Undervoltage releases – mountable on the right
MS45x, 24
50/60
MS49x, 110/120
50/60
MO45x,
230/240
50/60
MO49x
400/440
50/60
230/240
50/60
400/440
50/60
UA4-24
UA4-110
UA4-230
UA4-400
UA4-HK-230
UA4-HK-400
1SAM401905R1004
1SAM401905R1001
1SAM401905R1002
1SAM401905R1003
1SAM401906R1001
1SAM401906R1002
1
1
1
1
1
1
0.134
0.134
0.131
0.129
0.140
0.137
2CDC241025F0011
AA4-24
Frequency
2CDC131051C0201
UA4-110
2/32 | ABB
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
General technical data
Type
Standards
Rated operational voltage Ue
Conventional free-air thermal current Ith
Rated frequency
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Pollution degree
Ambient air temperature
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
HK4-11
HK4-W
IEC/EN 60947–1, IEC/EN 60947-5-1, UL 508,
230 V AC / 220 V DC 690 V AC / 220 V DC
2.5 A
5A
DC, 50/60 Hz
6 kV
300 V
300 V
3
-20 ... +70 °C
-50 ... +80 °C
25g / 11 ms
2g / 5 ... 150 Hz
Number of poles
1 N.C. + 1 N.O.
Changeover
1 N.C. + 1 N.O. /
2 N.O. / 2 N.C.
2 N.C. + 2 N.O.
Operation
Storage
HKS4
CSA22.2 No. 14
690 V AC
10 A
SK4
690 V AC
10 A
690 V
690 V
2
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
2A
4A
6A
6A
230 V
0.5 A
3A
4A
4A
400 V
-
1.5 A
3A
3A
690 V
-
0.5 A
1A
1A
24 V
1A
1A
2A
2A
48 V
0.3 A
-
-
-
60 V
24 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
-
-
-
-
0.22 A
0.5 A
0.5 A
230 V
-
0.1 A
0.25 A
0.25 A
-
-
Left side of MMS
Left side of MMS
Minimum switching capacity
17 V / 1 mA
Short-circuit protective device
10 A Type gG
Duty time
100 %
Mounting
Front of MMS
Mounting positions
1-6
Mechanical durability
100000 cycles
Electrical durability
100000 cycles
Type
Power consumption
Pull-in
UA4-xxx
AA4-xxx
20.2/13 VA/W
20 W
7.2/2.4 VA/W
2.1 W
20.2/13 VA/W
13 … 80 W
-
0.35 … 0.7 V x Us
0.85 … 1.1 V x Us
0.7 … 1.1 V x Us
-
Holding
Operating voltage
Tripping
Coil operating voltage
AC
DC
AC
DC
Front of MMS
2CDC131051C0201
0.15 A
110 V
ABB | 2/33
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
Connecting characteristics
Auxiliary circuit
Type
Connecting capacity
2
HK4-11
Rigid
Flexible with ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
HKS4
SK4
0.5... 2.5 mm²
0.5 ... 1.5 mm² or 0.75 ... 2.5 mm
0.5 ... 2.5 mm²
0.5 ... 1.5 mm² or 0.75 ... 2.5 mm
0.5 ... 2.5 mm²
0.5 ... 1.5 mm² or 0.75 ... 2.5 mm
AWG 18-14
AWG 18-14
10 mm
0.8 ... 1.2 Nm / 7 ... 10.3 Ib.in
Pozidriv 2
2CDC131051C0201
Stripping length
Tightening torque
Recommended screw driver
1x
2x
1x
2x
1x
2x
1 or 2 x
1 or 2 x
HK4-W
2/34 | ABB
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
2CDC241003F0012
Description
PS4-2-0
Three-phase busbars ensure a quick and safe connection and are therefor a cost effective solution.
A variety of different three-phase busbars up to 108 A are in the assortment. Between 2 and 4 manual
motor starter with none or two lateral auxiliary contacts can be connected.
2CDC241004F0012
Suitable for
2CDC241005F0012
PS4-3-0
2CDC241023F0013
Rated opera- Number of
tional current MMS
A
Three-phase busbars
MS450,
108 A
MO450
108 A
108 A
108 A
108 A
108 A
Suitable for
PS4-4-0
2
Ordering details
2
3
4
2
3
4
Number of
lateral aux.
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
0
0
0
1
1
1
PS4-2-0
PS4-3-0
PS4-4-0
PS4-2-2
PS4-3-2
PS4-4-2
1SAM401911R1001
1SAM401911R1002
1SAM401911R1003
1SAM401911R1004
1SAM401911R1005
1SAM401911R1006
5
5
5
5
5
5
0.134
0.206
0.280
0.148
0.250
0.362
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
S4-M1
1SAM401911R1007
2
0.106
Rated opera- Rated cross Mounting
tional current section
form
A
mm²
Three-phase feeder terminals
MS450,
108 A
25
MO450
Flat
SA2
Suitable for
Description
Type
Order code
Pkg
qty
Weight
(1 pce)
MS450, MO450
Protection cover for busbar
Disconnector module
Terminal shroud
Terminal shroud
Terminal shroud
Terminal insulation barrier for
UL508E
Padlock + two keys
BS4-3
TB450
KA450
KA495
KA495C 1)
DX495
1SAM401911R1008
1SAM401910R1001
1SAM401908R1001
1SAM501901R1001
1SAM501902R1001
1SAM401912R1001
10
1
1
10
10
1
kg
0.001
0.315
0.154
0.018
0.038
0.154
SA2
GJF1101903R0002
10
0.020
MS495, MS497,
MO495, MO496
MS450, MS495, MS497,
MO450, MO495, MO496
Is plugged onto the housing after removing the box terminals, if using cable lugs.
2CDC131051C0201
1)
ABB | 2/35
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
General technical data
PS4-xxx
IEC/EN 60947-1
690 V AC
108 A
50/60 Hz
6 kV
690 V AC
3
10 mm²
-25 ... +70 °C
-50 ... +80 °C
Operation
Storage
S4-M1
25 mm²
Connecting characteristics
Main circuit
Type
Connecting capacity
S4-M1
Rigid
Flexible with ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Tightening torque
Recommended screw driver
1x
1x
1x
1x
1x
2.5 ... 50 mm²
4 ... 16 mm²
4 ... 16 mm²
AWG 14-4
AWG 14-4
4 Nm
Pozidriv 2
Please check for further equipment chapter General accessories.
2CDC131051C0201
2
Type
Standards
Rated operational voltage Ue
Rated operational current Ie
Rated frequency
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Pollution degree
Cross-section
Ambient air temperature
2/36 | ABB
Notes
N19
2
ABB | 2/37
MS116, MS132, MO132, MS4xx, MO4xx
General accessories
Description
2CDC241003F0011
With this solution of door coupling rotary mechanism it is possible to operate a Manual Motor Starter in the
back of a switch cabinet from outside. The door coupling mechanism prevents opening of the door of a
switch cabinet with the Manual Motor Starter in ON position.
The complete mechanism includes handle, shaft, driver, shaft alignment ring and shaft supporter.
All accessories fit for 6 mm shafts with a maximum length of 180 mm. The degree of protection for
handles MSHD is IP64.
2
Ordering details
Suitable
for
MSHD-LB
Description
2CDC241002S0011
Shafts
MS116, For MSHD handles. Shaft
MS132, diameter 6 mm. Shaft extension
MO132, for door coupling driver.
MS4xx,
MO4xx
IP64 handles (UL: Type 1, 3R, 12)
MS116, Padlockable max. 3 padlocks
MS132, with bail diameter 5 … 8 mm,
MO132, door interlock in ON position
MS4xx, defeatable, for use with 6 mm
MO4xx OXS6…types up to 180 mm or
driver shafts MSOX.
2CDC241004F0011
MSHD-LY
Driver
MS116, Coupling driver for use with
MS132, 6 mm OXS6… types up to
MO132, 180 mm.
MS4xx,
MO4xx
2CDC241001F0012
MSMN
Shaft alignment ring
MS116, The MSH-AR supports the
MS132, long shafts for alignment to the
MO132, handle inlet. It makes closing
MS4xx, panel doors more easy. Use for
MO4xx OXS6X > 105 mm.
MSH-AR
2CDC241017V0013
Shaft supporter
MS116, With the MSAH it is possible
MS132, to support the shaft in the
MO132 extension of handle (MSHD). It
is mandatory for the usage of
shafts >130 mm.
Shaft Color
length
Type
Order code
Pkg
qty
mm
Weight
(1 pce)
kg
85
105
130
180
Black
Yellow
Black
Yellow
OXS6X85
OXS6X105
OXS6X130
OXS6X180
1SCA101647R1001
1SCA108043R1001
1SCA101655R1001
1SCA101659R1001
1
1
1
1
0.020
0.020
0.030
0.040
MSHD-LB 1)
MSHD-LY 1)
MSHD-LTB 2)
MSHD-LTY 2)
1SAM201920R1001
1SAM201920R1002
1SAM201920R1011
1SAM201920R1012
1
1
1
1
0.065
0.065
0.065
0.065
MSMN 3)
MSMNO 4)
1SAM101923R0002
1SAM101923R0012
1
1
0.002
0.002
MSH-AR
1SAM201920R1000
1
0.010
MSAH1
1SAM201909R1021
1
0.035
Indication I-O and ON-OFF (recommended for MS116, MS4xx, MO4xx)
Indication I-O and ON-OFF + Trip indication
3)
Coded - Positioning of ON indication dependent from mounting orientation of the MMS
4)
Uncoded - Positioning of ON indication independent from mounting orientation of the MMS
1)
2)
2CDC131053C0201
MSAH1
2/38 | ABB
MS116, MS132, MO132, MS4xx, MO4xx
General accessories
2
MSMN
MSMNO
MSAH1
OXS6X
2CDC131053C0201
MSHD
2CDC242022F0013
MSH-AR
ABB | 2/39
Summary_3
3
3/0 | ABB
With screw terminals
3-pole contactors
B6, B7 AC operated
BC6, BC7, B7D DC operated
3/4
3/5
3-pole reversing contactors
VB6, VB7 AC operated
VBC6, VBC7 DC operated
VB6A, VB7A AC operated
VBC6A, VBC7A DC operated
3/6
3/7
3/8
3/9
3-pole interface contactors
BC6, BC7 DC operated
3/10
3-pole contactors - large coil voltage range
TBC7 DC operated
3/11
4-pole contactors
B6, B7 AC operated
BC6, B7D DC operated
3/12
3/13
4-pole contactors - large coil voltage range
TBC7 DC operated
3/14
Contactor relays
K6 AC operated
KC6 DC operated
3/15
3/16
Interface contactor relays
KC6 DC operated
3/17
Contactor relays - large coil voltage range
TKC6 DC operated
3/18
3
With soldering pins
3-pole contactors
B6, B7 AC operated
BC6, BC7 DC operated
3/19
3/20
3-pole reversing contactors
VB6, VB7 AC operated
VBC6, VBC7 DC operated
VB6A, VB7A AC operated
VBC7A DC operated
3/21
3/22
3/23
3/24
Contactor relays
K6 AC operated
KC6 DC operated
3/25
3/26
3-pole interface contactors
BC6, BC7 DC operated
3/27
Interface contactors relays
KC6 DC operated
3/28
With flat pin connection
3-pole contactors
B6, B7 AC operated
BC6, BC7 DC operated
3/29
3/30
3-pole reversing contactors
VB7 AC operated
VBC7 DC operated
VB7A AC operated
VBC7A DC operated
3/31
3/32
3/33
3/34
3-pole interface contactors
BC6, BC7 DC operated
3/35
Contactors relays
K6 AC operated
KC6 DC operated
3/36
3/37
Interface contactors relays
KC6 DC operated
3/38
Accessories
3/39
Technical data
3/41
ABB | 3/1
Summary_3
B mini contactors
K mini contactor relays
Mini contactors
Screw terminals
AC Control supply
3-pole contactors
Coil consumption 3.5 W
Type
B6
B7
-
-
3-pole reversing contactors
Coil consumption 3.5 W
Type
-
-
VB6
VB6A2)
VB7
VB7A2)
4-pole contactors
Coil consumption 3.5 W
Type
B6
B7
-
-
3-pole contactors
Coil consumption 3.5 W
Type
BC6
-
-
3-pole interface contactors
Coil consumption 1.4 ... 2.4 W
Type
BC6
BC7
B7D1)
BC7
-
-
3-pole reversing contactors
Coil consumption 3.5 W
Type
-
-
VBC6
VBC6A2)
VBC7
VBC7A2)
4-pole contactors
Coil consumption 3.5 W
Type
BC6
Wide range types
Type
-
B7D
TBC7
PLC types
Extended coil voltage and
temperature
Coil consumption 1.7 W
Type
B6S1)
B7S1)
IEC
220-230-240 V
kW 2.2
3
2.2
3
380-400 V
kW 4
5.5
4
5.5
20
20
20
DC Control supply
3
Rated operational power AC-3
Rated operational current AC-1
UL/CSA 3-phase motor rating
400 V, θ ≤ 40 °C
A 20
220-240 V AC
hp 2
3
2
3
440-480 V AC
hp 3
5
3
5
16 (600 V)
12 (300 V)
16 (600 V)
A 12 (300 V)
General use rating
With integrated surge suppressor
2)
With safety blocking function
1)
Main accessories
Auxiliary contact blocks
Connection sets
Surge suppressors
Front mounting
Side mounting
For reversing contactors
Varistor (AC/DC)
CAF6
CA6
BSM6-30
RV-BC6
Overload relays
Class 10 T16
Thermal overload relays
Thermal and phase failure protection, with single setup possible
Class 10E, 20E, 30E E16DU
Electronic overload relays
With single setup possible
Manual motor starters
Thermal / magnetic protection
Magnetic only types
Connecting link to manual motor starters
Class 10 MS116, MS132
MO132
BEA7/132
Contactor relays
Screw terminals
AC Control supply
Coil consumption 3.5 W
Type
4-pole contactor relays
Coil consumption 3.5 W
Type
4-pole interface contactor relays
Coil consumption 1.4 ... 2.4 W
Type
4-pole contactor relays
K6
DC Control supply
Extended coil voltage and
temperature
Rated operational current AC-15 220-230-240 V
380-400 V
Rated operational current DC-13 24 V
Wide range types
IEC
KC6
KC6
Type TKC6
A 4
A 3
A 2.5
Main accessories
Auxiliary contact blocks
2
Front mounting
Side mounting
CAF6
CA6-11K
Soldering pins
Flat pins
B6...P
B7...P
-
-
B6...F
B7...F
-
-
-
-
VB6...P
VB6A...P2)
VB7...P
VB7A...P2)
-
-
VB6...F
VB6A...F2)
VB7...F
VB7A...F2)
-
-
-
-
-
-
BC6...P
-
-
BC6...F
-
-
-
BC6...F
BC7...F
B7D...F1)
BC7...F
-
BC6...P
BC7...P
B7D...P1)
BC7...P
-
-
-
-
VBC6...P
VBC6A...P2)
VBC7...P
VBC7A...P2)
-
-
VBC6...F
VBC6A...F2)
VBC7...F
VBC7A...F2)
-
-
-
-
2.2
3
2.2
3
2.2
3
2.2
3
4
5.5
4
5.5
4
5.5
4
5.5
12
12
12
12
20
20
20
20
2
3
2
3
2
3
2
3
3
5
3
5
3
5
3
5
12 (300 V)
16 (600 V)
12 (300 V)
16 (600 V)
12 (300 V)
16 (600 V)
12 (300 V)
16 (600 V)
CA6-11K-F
-
-
-
-
-
MS116, MS132
MO132
-
MS116, MS132
MO132
-
Soldering pins
Flat pins
K6...P
K6...F
KC6...P
KC6...P
KC6...F
KC6...F
4
3
2.5
4
3
2.5
CA6-11K-P
CA6-11K-F
2CDC102050C0201
CA6-11K-P
-
3
ABB | 3/3
B6, B7 3-pole mini contactors – with screw terminals
4 to 5.5 kW
AC operated
2CDC211001F0010
Description
B6-30-10
Ordering details
2CDC211014F0011
B7-30-10
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit
3-phase General voltage
UC
motor use
rating
rating
50 Hz
60 Hz
480 V
hp
B6 mini contactors
4
20
3
300 V /
12 A
V AC
V AC
24
24
42
42
48
48
Auxiliary Type
contacts
fitted
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
B7 mini contactors
5.5
20
5
600 V /
16 A
24
24
42
42
48
48
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
Order code
Pkg Weight
qty (1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
B6-30-10-01
B6-30-01-01
B6-30-10-02
B6-30-01-02
B6-30-10-03
B6-30-01-03
B6-30-10-84
B6-30-01-84
B6-30-10-80
B6-30-01-80
B6-30-10-85
B6-30-01-85
GJL1211001R0101
GJL1211001R0011
GJL1211001R0102
GJL1211001R0012
GJL1211001R0103
GJL1211001R0013
GJL1211001R8104
GJL1211001R8014
GJL1211001R8100
GJL1211001R8010
GJL1211001R8105
GJL1211001R8015
10
10
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
B7-30-10-01
B7-30-01-01
B7-30-10-02
B7-30-01-02
B7-30-10-03
B7-30-01-03
B7-30-10-84
B7-30-01-84
B7-30-10-80
B7-30-01-80
B7-30-10-85
B7-30-01-85
GJL1311001R0101
GJL1311001R0011
GJL1311001R0102
GJL1311001R0012
GJL1311001R0103
GJL1311001R0013
GJL1311001R8104
GJL1311001R8014
GJL1311001R8100
GJL1311001R8010
GJL1311001R8105
GJL1311001R8015
10
10
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
B6, B7
3/4 | ABB
2CDC102008C0201
52.5
2CDC212001F0011
Main dimensions
57.5
3
B6, B7 3-pole mini contactors are compact control products mainly used for switching resistive or motor
loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
–– hum-free coil
–– designed for rail or wall mounting
BC6, BC7, B7D 3-pole mini contactors – with screw terminals
4 to 5.5 kW
DC operated
2CDC211040F0011
Description
BC6-30-10
BC6, BC7, B7D 3-pole mini contactors are compact control products mainly used for switching resistive or
motor loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated, low consumption (3.5 W at pull-in and at holding)
– – hum-free coil
– – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
– – designed for rail or wall mounting
3
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
BC6 mini contactors
4
20
3
Order code
Pkg Weight
qty (1 pce)
V DC
300 V /
12 A
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
BC6-30-10-07
BC6-30-01-07
BC6-30-10-01
BC6-30-01-01
BC6-30-10-16
BC6-30-01-16
BC6-30-10-03
BC6-30-01-03
BC6-30-10-04
BC6-30-01-04
BC6-30-10-05
BC6-30-01-05
GJL1213001R0107
GJL1213001R0017
GJL1213001R0101
GJL1213001R0011
GJL1213001R1106
GJL1213001R1016
GJL1213001R0103
GJL1213001R0013
GJL1213001R0104
GJL1213001R0014
GJL1213001R0105
GJL1213001R0015
10
10
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
12
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
BC7-30-10-07
BC7-30-01-07
BC7-30-10-01
BC7-30-01-01
BC7-30-10-16
BC7-30-01-16
BC7-30-10-03
BC7-30-01-03
BC7-30-10-04
BC7-30-01-04
BC7-30-10-05
BC7-30-01-05
GJL1313001R0107
GJL1313001R0017
GJL1313001R0101
GJL1313001R0011
GJL1313001R1106
GJL1313001R1016
GJL1313001R1103
GJL1313001R0013
GJL1313001R0104
GJL1313001R0014
GJL1313001R0105
GJL1313001R0015
10
10
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
B7D mini contactors with integrated suppressor diode
5.5
20
5
600 V / 24
1
16 A
0
220
1
0
0
1
0
1
B7D-30-10-01
B7D-30-01-01
B7D-30-10-05
B7D-30-01-05
GJL1317001R0101
GJL1317001R0011
GJL1317001R0105
GJL1317001R0015
10
10
10
10
0.175
0.175
0.175
0.175
24
48
60
110 … 125
220 … 240
BC7 mini contactors
5.5
20
5
600 V /
16 A
12
24
48
60
110 … 125
220 … 240
Other types on request
2.26"
1.78"
1.66"
42.2
47.5
2.07"
1.87"
mm, inches
46.7 1.84"
43.7 1.72"
4.5 0.18"
2CDC102015C0201
52.5
2CDC212001F0011
Main dimensions
45.2
BC7-30-10
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
57.5
2CDC211013F0011
Ordering details
BC6, BC7, B7D
ABB | 3/5
VB6, VB7 3-pole mini reversing contactors – with screw terminals
4 to 5.5 kW
AC operated
2CDC211006F0011
Description
VB7-30-10
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit
3-phase General voltage
UC
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
VB6 mini reversing contactors
4
20
3
300 V /
12 A
VB7 mini reversing contactors
5.5
20
5
600 V /
16 A
V AC
V AC
24
24
42
42
48
48
110 … 127
110 … 127
220 … 240
220 … 240
380 … 415
380 … 415
24
24
42
42
48
48
110 … 127
110 … 127
220 … 240
220 … 240
380 … 415
380 … 415
Auxiliary Type
contacts
fitted
Order code
Pkg Weight
qty (1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB6-30-10-01
VB6-30-01-01
VB6-30-10-02
VB6-30-01-02
VB6-30-10-03
VB6-30-01-03
VB6-30-10-84
VB6-30-01-84
VB6-30-10-80
VB6-30-01-80
VB6-30-10-85
VB6-30-01-85
GJL1211901R0101
GJL1211901R0011
GJL1211901R0102
GJL1211901R0012
GJL1211901R0103
GJL1211901R0013
GJL1211901R8104
GJL1211901R8014
GJL1211901R8100
GJL1211901R8010
GJL1211901R8105
GJL1211901R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB7-30-10-01
VB7-30-01-01
VB7-30-10-02
VB7-30-01-02
VB7-30-10-03
VB7-30-01-03
VB7-30-10-84
VB7-30-01-84
VB7-30-10-80
VB7-30-01-80
VB7-30-10-85
VB7-30-01-85
GJL1311901R0101
GJL1311901R0011
GJL1311901R0102
GJL1311901R0012
GJL1311901R0103
GJL1311901R0013
GJL1311901R8104
GJL1311901R8014
GJL1311901R8100
GJL1311901R8010
GJL1311901R8105
GJL1311901R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
Other types on request
Main dimensions
mm, inches
46.7 1.84"
43.7 1.72"
VB6, VB7
3/6 | ABB
2CDC102016C0201
4.5 0.18"
2CDC212005F0011
42.2 1.66"
45.2 1.78"
96.2 3.79"
57.5 2.26"
3
VB6, VB7 3-pole compact design reversing contactors are space optimized control products mainly used
for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc.
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front mounting
–– designed for rail or wall mounting
VBC6, VBC7 3-pole mini reversing contactors – with screw terminals
4 to 5.5 kW
DC operated
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
VBC6 mini reversing contactors
4
20
3
300 V /
12 A
12
24
48
60
110 ... 125
220 … 240
VBC7 mini reversing contactors
5.5
20
5
600 V /
16 A
12
24
48
60
110 ... 125
220 … 240
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VBC6-30-10-07
VBC6-30-01-07
VBC6-30-10-01
VBC6-30-01-01
VBC6-30-10-16
VBC6-30-01-16
VBC6-30-10-03
VBC6-30-01-03
VBC6-30-10-04
VBC6-30-01-04
VBC6-30-10-05
VBC6-30-01-05
GJL1213901R0107
GJL1213901R0017
GJL1213901R0101
GJL1213901R0011
GJL1213901R1106
GJL1213901R1016
GJL1213901R0103
GJL1213901R0013
GJL1213901R0104
GJL1213901R0014
GJL1213901R0105
GJL1213901R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VBC7-30-10-07
VBC7-30-01-07
VBC7-30-10-01
VBC7-30-01-01
VBC7-30-10-16
VBC7-30-01-16
VBC7-30-10-03
VBC7-30-01-03
VBC7-30-10-04
VBC7-30-01-04
VBC7-30-10-05
VBC7-30-01-05
GJL1313901R0107
GJL1313901R0017
GJL1313901R0101
GJL1313901R0011
GJL1313901R1106
GJL1313901R1016
GJL1313901R0103
GJL1313901R0013
GJL1313901R0104
GJL1313901R0014
GJL1313901R0105
GJL1313901R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
Other types on request
Main dimensions
mm, inches
46.7 1.84"
96.2 3.79"
43.7 1.72"
2CDC102017C0201
4.5 0.18"
2CDC212005F0011
42.2 1.66"
VBC7-30-10
3
Ordering details
45.2 1.78"
2CDC211001F0011
VBC6-30-10
VBC6, VBC7 3-pole compact design reversing contactors are space optimized control products mainly
used for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc.
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front mounting
–– designed for rail or wall mounting
57.5 2.26"
2CDC211042F0011
Description
VBC6, VBC7
ABB | 3/7
VB6A, VB7A 3-pole mini reversing contactors – with screw terminals
4 to 5.5 kW
AC operated – with safety blocking function
2CDC211037F0011
Description
VB6A-30-10
2CDC211008F0011
VB7A-30-10
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit
3-phase General voltage
UC
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
V AC
Auxiliary Type
contacts
fitted
Order code
Pkg Weight
qty (1 pce)
V AC
kg
VB6A mini reversing contactors with safety blocking function
4
20
3
300 V / 24
24
1
12 A
0
42
42
1
0
48
48
1
0
110 … 127 110 … 127
1
0
220 … 240 220 … 240
1
0
380 … 415 380 … 415
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB6A-30-10-01
VB6A-30-01-01
VB6A-30-10-02
VB6A-30-01-02
VB6A-30-10-03
VB6A-30-01-03
VB6A-30-10-84
VB6A-30-01-84
VB6A-30-10-80
VB6A-30-01-80
VB6A-30-10-85
VB6A-30-01-85
GJL1211911R0101
GJL1211911R0011
GJL1211911R0102
GJL1211911R0012
GJL1211911R0103
GJL1211911R0013
GJL1211911R8104
GJL1211911R8014
GJL1211911R8100
GJL1211911R8010
GJL1211911R8105
GJL1211911R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
VB7A mini reversing contactors with safety blocking function
5.5
20
5
600 V / 24
24
1
16 A
0
42
42
1
0
48
48
1
0
110 … 127 110 … 127
1
0
220 … 240 220 … 240
1
0
380 … 415 380 … 415
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB7A-30-10-01
VB7A-30-01-01
VB7A-30-10-02
VB7A-30-01-02
VB7A-30-10-03
VB7A-30-01-03
VB7A-30-10-84
VB7A-30-01-84
VB7A-30-10-80
VB7A-30-01-80
VB7A-30-10-85
VB7A-30-01-85
GJL1311911R0101
GJL1311911R0011
GJL1311911R0102
GJL1311911R0012
GJL1311911R0103
GJL1311911R0013
GJL1311911R8104
GJL1311911R8014
GJL1311911R8100
GJL1311911R8010
GJL1311911R8105
GJL1311911R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
Other types on request
Main dimensions
mm, inches
46.7 1.84"
3/8 | ABB
2CDC102018C0201
4.5 0.18"
VB6A, VB7A
2CDC212005F0011
43.7 1.72"
42.2 1.66"
45.2 1.78"
96.2 3.79"
57.5 2.26"
3
VB6A, VB7A 3-pole compact design reversing contactors are space optimized control products mainly
used for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the
voltage is applied to the coil of the contactor to be switched on before the contactor to be switched
off has dropped out. The contactor coils are designed for continuous operation when the contactor is
de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor
with the coil voltage applied.
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front mounting
–– designed for rail or wall mounting
VBC6A, VBC7A 3-pole mini reversing contactors – with screw terminals
4 to 5.5 kW
DC operated – with safety blocking function
2CDC211044F0011
Description
2CDC211007F0011
VBC6A-30-10
VBC6A, VBC7A 3-pole compact design reversing contactors are space optimized control products mainly
used for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the
voltage is applied to the coil of the contactor to be switched on before the contactor to be switched
off has dropped out. The contactor coils are designed for continuous operation when the contactor is
de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor
with the coil voltage applied.
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front mounting
–– designed for rail or wall mounting
3
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
kg
VBC6A mini reversing contactors with safety blocking function
4
20
3
300 V / 12
1 0 VBC6A-30-10-07
12 A
0 1 VBC6A-30-01-07
24
1 0 VBC6A-30-10-01
0 1 VBC6A-30-01-01
48
1 0 VBC6A-30-10-16
0 1 VBC6A-30-01-16
60
1 0 VBC6A-30-10-03
0 1 VBC6A-30-01-03
110 ... 125
1 0 VBC6A-30-10-04
0 1 VBC6A-30-01-04
220 … 240
1 0 VBC6A-30-10-05
0 1 VBC6A-30-01-05
GJL1213911R0107
GJL1213911R0017
GJL1213911R0101
GJL1213911R0011
GJL1213911R1106
GJL1213911R1016
GJL1213911R0103
GJL1213911R0013
GJL1213911R0104
GJL1213911R0014
GJL1213911R0105
GJL1213911R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
VBC7A mini reversing contactors with safety blocking function
5.5
20
5
600 V / 12
1 0 VBC7A-30-10-07
16 A
0 1 VBC7A-30-01-07
24
1 0 VBC7A-30-10-01
0 1 VBC7A-30-01-01
48
1 0 VBC7A-30-10-16
0 1 VBC7A-30-01-16
60
1 0 VBC7A-30-10-03
0 1 VBC7A-30-01-03
110 ... 125
1 0 VBC7A-30-10-04
0 1 VBC7A-30-01-04
220 … 240
1 0 VBC7A-30-10-05
0 1 VBC7A-30-01-05
GJL1313911R0107
GJL1313911R0017
GJL1313911R0101
GJL1313911R0011
GJL1313911R1106
GJL1313911R0016
GJL1313911R0103
GJL1313911R0013
GJL1313911R0104
GJL1313911R0014
GJL1313911R0105
GJL1313911R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
0.355
Other types on request
Main dimensions
mm, inches
46.7 1.84"
2CDC102019C0201
4.5 0.18"
2CDC212005F0011
43.7 1.72"
42.2 1.66"
45.2 1.78"
96.2 3.79"
57.5 2.26"
VBC7A-30-10
VBC6A, VBC7A
ABB | 3/9
BC6, BC7 3-pole interface mini contactors – with screw terminals
4 to 5.5 kW
DC operated
2CDC211040F0011
Description
BC6-30-10
Ordering details
2CDC211013F0011
BC7-30-10
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
5.5
20
5
300 V /
12 A
24
600 V /
16 A
24
DC operation 17 … 32 V / 2.4 W
4
20
3
300 V /
12 A
17 ... 32
5.5
17 ... 32
20
Order code
Pkg Weight
qty (1 pce)
V DC
DC operation 24 V / 1.4 W
4
20
3
5
600 V /
16 A
kg
1
0
1
0
0
1
0
1
BC6-30-10-1.4-81
BC6-30-01-1.4-81
BC7-30-10-1.4-81
BC7-30-01-1.4-81
GJL1213001R8101
GJL1213001R8011
GJL1313001R8101
GJL1313001R8011
10
10
10
10
0.175
0.175
0.175
0.175
1
0
1
0
0
1
0
1
BC6-30-10-2.4-51
BC6-30-01-2.4-51
BC7-30-10-2.4-51
BC7-30-01-2.4-51
GJL1213001R5101
GJL1213001R5011
GJL1313001R5101
GJL1313001R5011
10
10
10
10
0.175
0.175
0.175
0.175
Connection to PLCs with integrated protective circuit
DC operation 24 V / 1.7 W
4
20
3
5.5
20
5
300 V /
12 A
24
600 V /
16 A
24
DC operation 17 … 32 V / 2.8 W
4
20
3
300 V /
12 A
17 ... 32
5.5
17 ... 32
20
5
600 V /
16 A
1
0
1
0
0
1
0
1
B6S-30-10-1.7-71
B6S-30-01-1.7-71
B7S-30-10-1.7-71
B7S-30-01-1.7-71
GJL1213001R7101
GJL1213001R7011
GJL1313001R7101
GJL1313001R7011
10
10
10
10
0.175
0.175
0.175
0.175
1
0
1
0
0
1
0
1
B6S-30-10-2.8-72
B6S-30-01-2.8-72
B7S-30-10-2.8-72
B7S-30-01-2.8-72
GJL1213001R7102
GJL1213001R7012
GJL1313001R7102
GJL1313001R7012
10
10
10
10
0.175
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
BC6, BC7
3/10 | ABB
2CDC102010C0201
52.5
2CDC212001F0011
Main dimensions
57.5
3
BC6, BC7 3-pole interface mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated, very low coil consumption. Suitable for direct control by PLC outputs
– – hum-free coil
– – no auxiliary contact block permitted for mounting
– – designed for rail or wall mounting
TBC7 3-pole mini contactors – with screw terminals
4 to 5.5 kW
DC operated – large coil voltage range
3
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UCmin ... UCmax fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
TBC7 mini contactors
5.5
20
5
600 V /
16 A
17 ... 32
50 ... 90
77 ... 143
140 ... 260
kg
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
TBC7-30-10-51
TBC7-30-01-51
TBC7-30-10-55
TBC7-30-01-55
TBC7-30-10-62
TBC7-30-01-62
TBC7-30-10-68
TBC7-30-01-68
GJL1313061R5101
GJL1313061R5011
GJL1313061R5105
GJL1313061R5015
GJL1313061R6102
GJL1313061R6012
GJL1313061R6108
GJL1313061R6018
10
10
10
10
10
10
10
10
0.185
0.185
0.185
0.185
0.185
0.185
0.185
0.185
Other types on request
2.26"
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
2CDC102020C0201
52.5
2CDC212001F0011
Main dimensions
45.2
TBC7-30-10
TBC7 3-pole mini contactors are compact control products mainly used for switching resistive or motor
loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated
– – low coil consumption (5 W at pull-in and at holding)
– – hum-free coil
–– expanded ambient temperature range -30 … +70 °C and wide range voltage supply
–– no auxiliary contact block permitted for mounting
–– designed for rail or wall mounting
–– material is approved for railway applications
57.5
2CDC211015F0011
Description
TBC7
ABB | 3/11
B6, B7 4-pole mini contactors – with screw terminals
4 to 5.5 kW
AC operated
2CDC211028F0011
Description
B6-22-00
Ordering details
IEC
UL/CSA
Rated operational General use
current
rating
θ ≤ 40 °C
AC-1
Rated control Auxiliary Type
circuit voltage contacts
UC
fitted
50/60 Hz
A
V AC
4 N.O. main poles
20
300 V / 12 A
20
600 V / 16 A
2 N.O. + 2 N.C. main poles
20
300 V / 12 A
20
600 V / 16 A
Order code
Pkg
qty
Weight
(1 pce)
kg
24
42
48
110 ... 127
220 ... 240
24
42
48
110 ... 127
220 ... 240
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B6-40-00-01
B6-40-00-02
B6-40-00-03
B6-40-00-84
B6-40-00-80
B7-40-00-01
B7-40-00-02
B7-40-00-03
B7-40-00-84
B7-40-00-80
GJL1211201R0001
GJL1211201R0002
GJL1211201R0003
GJL1211201R8004
GJL1211201R8000
GJL1311201R0001
GJL1311201R0002
GJL1311201R0003
GJL1311201R8004
GJL1311201R8000
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
24
42
48
110 ... 127
220 ... 240
24
42
48
110 ... 127
220 ... 240
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B6-22-00-01
B6-22-00-02
B6-22-00-03
B6-22-00-84
B6-22-00-80
B7-22-00-01
B7-22-00-02
B7-22-00-03
B7-22-00-84
B7-22-00-80
GJL1211501R0001
GJL1211501R0002
GJL1211501R0003
GJL1211501R8004
GJL1211501R8000
GJL1311501R0001
GJL1311501R0002
GJL1311501R0003
GJL1311501R8004
GJL1311501R8000
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
B6, B7
3/12 | ABB
2CDC102009C0201
52.5
2CDC212001F0011
Main dimensions
57.5
3
B6, B7 4-pole mini contactors are compact control products mainly used for switching resistive loads up
to 690 V AC.
These contactors are designed with:
– – 4 main poles
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
–– hum-free coil
–– designed for rail or wall mounting
BC6, B7D 4-pole mini contactors – with screw terminals
4 to 5.5 kW
DC operated
3
Ordering details
IEC
UL/CSA
Rated
operational
current
θ ≤ 40 °C
AC-1
A
General use
rating
Rated control Auxiliary Type
circuit voltage contacts
UC
fitted
Order code
Pkg Weight
qty (1 pce)
V DC
4 N.O. main poles
20
600 V / 16 A
2 N.O. + 2 N.C. main poles
20
300 V / 12 A
kg
24
220
0
0
0
0
B7D-40-00-01
B7D-40-00-05
GJL1317201R0001
GJL1317201R0005
10
10
0.175
0.175
12
24
42
48
60
110 ... 125
220 ... 240
0
0
0
0
0
0
0
0
0
0
0
0
0
0
BC6-22-00-07
BC6-22-00-01
BC6-22-00-02
BC6-22-00-16
BC6-22-00-03
BC6-22-00-04
BC6-22-00-05
GJL1213501R0007
GJL1213501R0001
GJL1213501R0002
GJL1213501R1006
GJL1213501R0003
GJL1213501R0004
GJL1213501R0005
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
2CDC102021C0201
52.5
2CDC212001F0011
Main dimensions
45.2
BC6-22-00
BC6, B7D 4-pole mini contactors are compact control products mainly used for switching resistive loads
up to 690 V AC.
These contactors are designed with:
– – 4 main poles
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front or side mounting
–– designed for rail or wall mounting
57.5
2CDC211032F0011
Description
BC6, B7D
ABB | 3/13
TBC7 4-pole mini contactors – with screw terminals
4 to 5.5 kW
DC operated – large coil voltage range
2CDC211026F0011
Description
TBC7-31-00
Ordering details
IEC
UL/CSA
Rated operational General use
current
rating
θ ≤ 40 °C
AC-1
A
3 N.O. + 1 N.C. main poles
20
600 V / 16 A
2 N.O. + 2 N.C. main poles
20
600 V / 16 A
Rated control Auxiliary Type
circuit voltage contacts
UC min ... UC max fitted
Order code
Pkg Weight
qty (1 pce)
V DC
kg
50 ... 90
77 ... 143
140 ... 260
0
0
0
0
0
0
TBC7-31-00-55
TBC7-31-00-62
TBC7-31-00-68
GJL1313461R5005
GJL1313461R6002
GJL1313461R6008
10
10
10
0.185
0.185
0.185
50 ... 90
77 ... 143
140 ... 260
0
0
0
0
0
0
TBC7-22-00-55
TBC7-22-00-62
TBC7-22-00-68
GJL1313561R5005
GJL1313561R6002
GJL1313561R6008
10
10
10
0.185
0.185
0.185
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
TBC7
3/14 | ABB
2CDC102022C0201
52.5
2CDC212001F0011
Main dimensions
57.5
3
TBC7 4-pole mini contactors are compact control products mainly used for switching resistive or motor
loads up to 690 V AC.
These contactors are designed with:
– – 4 main poles
– – control circuit: DC operated
– – low coil consumption (5 W at pull-in and at holding)
– – hum-free coil
–– expanded ambient temperature range -30 … +70 °C and wide range voltage supply
–– no auxiliary contact block permitted for mounting
–– designed for rail or wall mounting
–– material is approved for railway applications
K6 4-pole mini contactor relays – with screw terminals
AC operated
2CDC211012F0011
Description
K6-22Z
K6 4-pole mini-contactor relays are space optimized control products mainly used for control functions or
for small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front or side mounting
–– designed for rail or wall mounting
3
Type
50 Hz
60 Hz
V AC
V AC
Order code
Pkg Weight
qty (1 pce)
kg
K6 4-pole mini contactor relays
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
K6-22Z-01
K6-22Z-02
K6-22Z-03
K6-22Z-84
K6-22Z-80
K6-22Z-85
K6-31Z-01
K6-31Z-02
K6-31Z-03
K6-31Z-84
K6-31Z-80
K6-31Z-85
K6-40E-01
K6-40E-02
K6-40E-03
K6-40E-84
K6-40E-80
K6-40E-85
GJH1211001R0221
GJH1211001R0222
GJH1211001R0223
GJH1211001R8224
GJH1211001R8220
GJH1211001R8225
GJH1211001R0311
GJH1211001R0312
GJH1211001R0313
GJH1211001R8314
GJH1211001R8310
GJH1211001R8315
GJH1211001R0401
GJH1211001R0402
GJH1211001R0403
GJH1211001R8404
GJH1211001R8400
GJH1211001R8405
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
2CDC102011C0201
52.5
2CDC212001F0011
Main dimensions
45.2
K6-31Z
Rated control circuit voltage
UC
57.5
2CDC211004F0010
Ordering details
K6
ABB | 3/15
KC6 4-pole mini contactor relays – with screw terminals
DC operated
2CDC211016F0011
Description
KC6-22Z
Ordering details
Rated control circuit voltage
UC
Type
Order code
Pkg Weight
qty (1 pce)
V DC
kg
KC6 4-pole mini contactor relays
12
24
48
60
110 ... 125
220 ... 240
12
24
48
60
110 ... 125
220 ... 240
12
24
48
60
110 ... 125
220 ... 240
KC6-22Z-07
KC6-22Z-01
KC6-22Z-16
KC6-22Z-03
KC6-22Z-04
KC6-22Z-05
KC6-31Z-07
KC6-31Z-01
KC6-31Z-16
KC6-31Z-03
KC6-31Z-04
KC6-31Z-05
KC6-40E-07
KC6-40E-01
KC6-40E-16
KC6-40E-03
KC6-40E-04
KC6-40E-05
GJH1213001R0227
GJH1213001R0221
GJH1213001R1226
GJH1213001R0223
GJH1213001R0224
GJH1213001R0225
GJH1213001R0317
GJH1213001R0311
GJH1213001R1316
GJH1213001R0313
GJH1213001R0314
GJH1213001R0315
GJH1213001R0407
GJH1213001R0401
GJH1213001R1406
GJH1213001R0403
GJH1213001R0404
GJH1213001R0405
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
KC6
3/16 | ABB
2CDC102012C0201
52.5
2CDC212001F0011
Main dimensions
57.5
3
KC6 4-pole mini-contactor relays are space optimized control products mainly used for control functions
or for small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for front or side mounting
–– designed for rail or wall mounting
KC6 4-pole interface mini contactor relays – with screw terminals
DC operated
3
Ordering details
Rated control circuit voltage
UC
Type
Order code
Pkg Weight
qty (1 pce)
V DC
kg
DC operation 24 V / 1.4 W
24
24
KC6-31Z-1.4-81
KC6-40E-1.4-81
GJH1213001R8311
GJH1213001R8401
10
10
0.175
0.175
DC operation 17 ... 32 V / 2.4 W
17 ... 32
17 ... 32
KC6-31Z-2.4-51
KC6-40E-2.4-51
GJH1213001R5311
GJH1213001R5401
10
10
0.175
0.175
DC operation 24 V / 1.7 W
24
24
24
K6S-22Z-1.7-71
K6S-31Z-1.7-71
K6S-40E-1.7-71
GJH1213001R7221
GJH1213001R7311
GJH1213001R7401
10
10
10
0.175
0.175
0.175
DC operation 17 ... 32 V / 2.8 W
17 ... 32
17 ... 32
17 ... 32
K6S-22Z-2.8-72
K6S-31Z-2.8-72
K6S-40E-2.8-72
GJH1213001R7222
GJH1213001R7312
GJH1213001R7402
10
10
10
0.175
0.175
0.175
Other types on request
2.26"
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
2CDC102013C0201
52.5
2CDC212001F0011
Main dimensions
45.2
KC6-31Z
KC6 4-pole interface mini-contactor relays are space optimized control products mainly used for control
functions or for small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: DC operated
– – low coil consumption (1.4 ... 2.8 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for rail or wall mounting
57.5
2CDC211017F0011
Description
KC6
ABB | 3/17
TKC6 4-pole mini contactor relays – with screw terminals
DC operated – large coil voltage range
2CDC211021F0011
Description
TKC6-31Z
Ordering details
Rated control circuit voltage
UC min ... UC max
V DC
17 ... 32
50 ... 90
77 ... 143
140 ... 260
17 ... 32
50 ... 90
77 ... 143
140 ... 260
17 ... 32
50 ... 90
77 ... 143
140 ... 260
Type
Order code
Pkg Weight
qty (1 pce)
TKC6-22Z-51
TKC6-22Z-55
TKC6-22Z-62
TKC6-22Z-68
TKC6-31Z-51
TKC6-31Z-55
TKC6-31Z-62
TKC6-31Z-68
TKC6-40E-51
TKC6-40E-55
TKC6-40E-62
TKC6-40E-68
GJH1213061R5221
GJH1213061R5225
GJH1213061R6222
GJH1213061R6228
GJH1213061R5311
GJH1213061R5315
GJH1213061R6312
GJH1213061R6318
GJH1213061R5401
GJH1213061R5405
GJH1213061R6402
GJH1213061R6408
10
10
10
10
10
10
10
10
10
10
10
10
kg
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7 1.84"
43.7 1.72"
4.5 0.18"
TKC6
3/18 | ABB
2CDC102014C0201
52.5
2CDC212001F0011
Main dimensions
57.5
3
TKC6 4-pole mini contactors are space optimized control products mainly used for control functions or for
small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: DC operated, hum free, low consumption (5 W at pull-in and at holding)
– – expanded ambient temperature range -30 … +70 °C and wide range voltage supply
– – material is suitable for railway applications
– – humfree operating DC coil
– – no auxiliary contact block permitted for mounting
– – designed for rail or wall mounting
B6, B7 3-pole mini contactors – with soldering pins
4 to 5.5 kW
AC operated
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit
3-phase General voltage
UC
motor use
rating
rating
50 Hz
60 Hz
480 V
hp
B6 mini contactors
4
12
3
300 V /
12 A
V AC
V AC
24
24
42
42
48
48
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
B7 mini contactors
5.5
12
5
600 V /
16 A
24
24
42
42
48
48
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
Auxiliary Type
contacts
fitted
Order code
Pkg Weight
qty (1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
B6-30-10-P-01
B6-30-01-P-01
B6-30-10-P-02
B6-30-01-P-02
B6-30-10-P-03
B6-30-01-P-03
B6-30-10-P-84
B6-30-01-P-84
B6-30-10-P-80
B6-30-01-P-80
B6-30-10-P-85
B6-30-01-P-85
GJL1211009R0101
GJL1211009R0011
GJL1211009R0102
GJL1211009R0012
GJL1211009R0103
GJL1211009R0013
GJL1211009R8104
GJL1211009R8014
GJL1211009R8100
GJL1211009R8010
GJL1211009R8105
GJL1211009R8015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
B7-30-10-P-01
B7-30-01-P-01
B7-30-10-P-02
B7-30-01-P-02
B7-30-10-P-03
B7-30-01-P-03
B7-30-10-P-84
B7-30-01-P-84
B7-30-10-P-80
B7-30-01-P-80
B7-30-10-P-85
B7-30-01-P-85
GJL1311009R0101
GJL1311009R0011
GJL1311009R0102
GJL1311009R0012
GJL1311009R0103
GJL1311009R0013
GJL1311009R8104
GJL1311009R8014
GJL1311009R8100
GJL1311009R8010
GJL1311009R8105
GJL1311009R8015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
mm, inches
47.7 1.88"
4.3 0.17"
44.7 1.76"
2CDC102023C0201
47.5 1.87"
2CDC212003F0011
Main dimensions
1 0.04"
B7-30-10-P
3
Ordering details
42.2 1.66"
2CDC211011F0011
B6-30-10-P
B6..P and B7..P 3-pole mini contactors are compact control products mainly used for switching resistive
or motor loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
–– hum-free coil
–– add-on auxiliary contact blocks for side mounting
–– designed for soldering on PCB boards
45.2 1.78"
2CDC211003F0010
Description
B6, B7
ABB | 3/19
BC6, BC7 3-pole mini contactors – with soldering pins
4 to 5.5 kW
DC operated
2CDC211030F0011
Description
BC7-30-10-P
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
kg
BC6 mini contactors with 3 N.O. main poles
4
12
3
300 V / 12
12 A
24
48
60
110 … 125
220 … 240
BC7 mini contactors with 3 N.O. main poles
5.5
12
5
600 V / 12
16 A
24
48
60
110 … 125
220 … 240
BC6 mini contactors 2 N.O. + 1 N.C. main poles
4
12
3
300 V / 24
12 A
48
60
110 … 125
220 … 240
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
BC6-30-10-P-07
BC6-30-01-P-07
BC6-30-10-P-01
BC6-30-01-P-01
BC6-30-10-P-16
BC6-30-01-P-16
BC6-30-10-P-03
BC6-30-01-P-03
BC6-30-10-P-04
BC6-30-01-P-04
BC6-30-10-P-05
BC6-30-01-P-05
GJL1213009R0107
GJL1213009R0017
GJL1213009R0101
GJL1213009R0011
GJL1213009R1106
GJL1213009R1016
GJL1213009R0103
GJL1213009R0013
GJL1213009R0104
GJL1213009R0014
GJL1213009R0105
GJL1213009R0015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
BC7-30-10-P-07
BC7-30-01-P-07
BC7-30-10-P-01
BC7-30-01-P-01
BC7-30-10-P-16
BC7-30-01-P-16
BC7-30-10-P-03
BC7-30-01-P-03
BC7-30-10-P-04
BC7-30-01-P-04
BC7-30-10-P-05
BC7-30-01-P-05
GJL1313009R0107
GJL1313009R0017
GJL1313009R0101
GJL1313009R0011
GJL1313009R1106
GJL1313009R1016
GJL1313009R0103
GJL1313009R0013
GJL1313009R0104
GJL1313009R0014
GJL1313009R0105
GJL1313009R0015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
1
1
1
1
1
0
0
0
0
0
BC6-21-10-P-01
BC6-21-10-P-16
BC6-21-10-P-03
BC6-21-10-P-04
BC6-21-10-P-05
GJL1213109R0101
GJL1213109R1106
GJL1213109R0103
GJL1213109R0104
GJL1213109R0105
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
Other types on request
mm, inches
47.7 1.88"
3/20 | ABB
2CDC102024C0201
B6, B7
4.3 0.17"
44.7 1.76"
2CDC212003F0011
42.2 1.66"
47.5 1.87"
1 0.04"
Main dimensions
45.2 1.78"
3
BC6, BC7 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for side mounting
–– designed for soldering on PCB boards
VB6, VB7 3-pole mini reversing contactors – with soldering pins
4 to 5.5 kW
AC operated
3
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit Auxiliary Type
contacts
3-phase General voltage
UC
fitted
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
VB6 mini reversing contactors
4
12
3
300 V /
12 A
V AC
V AC
24
24
42
42
48
48
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
VB7 mini reversing contactors
5.5
12
5
600 V /
16 A
24
24
42
42
48
48
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
Order code
Pkg Weight
qty (1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB6-30-10-P-01
VB6-30-01-P-01
VB6-30-10-P-02
VB6-30-01-P-02
VB6-30-10-P-03
VB6-30-01-P-03
VB6-30-10-P-84
VB6-30-01-P-84
VB6-30-10-P-80
VB6-30-01-P-80
VB6-30-10-P-85
VB6-30-01-P-85
GJL1211909R0101
GJL1211909R0011
GJL1211909R0102
GJL1211909R0012
GJL1211909R0103
GJL1211909R0013
GJL1211909R8104
GJL1211909R8014
GJL1211909R8100
GJL1211909R8010
GJL1211909R8105
GJL1211909R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB7-30-10-P-01
VB7-30-01-P-01
VB7-30-10-P-02
VB7-30-01-P-02
VB7-30-10-P-03
VB7-30-01-P-03
VB7-30-10-P-84
VB7-30-01-P-84
VB7-30-10-P-80
VB7-30-01-P-80
VB7-30-10-P-85
VB7-30-01-P-85
GJL1311909R0101
GJL1311909R0011
GJL1311909R0102
GJL1311909R0012
GJL1311909R0103
GJL1311909R0013
GJL1311909R8104
GJL1311909R8014
GJL1311909R8100
GJL1311909R8010
GJL1311909R8105
GJL1311909R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
mm, inches
47.7 1.88"
4.3 0.17"
44.7 1.76"
1 0.04"
42.2 1.66"
96.2 3.79"
0.18"
2CDC102025C0201
4.5
2CDC212007F0011
Main dimensions
45.2 1.78"
VB7-30-10-P
VB6, VB7 3-pole compact design reversing contactors are space optimized control products mainly used
for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for soldering on PCB boards
57.5 2.26"
2CDC211010S0011
Description
VB6, VB7
ABB | 3/21
VBC6, VBC7 3-pole mini reversing contactors – with soldering pins
4 to 5.5 kW
DC operated
2CDC211009F0011
Description
VBC7-30-10-P
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
VBC6 mini reversing contactors
4
12
3
300 V /
12 A
12
24
48
60
110 ... 125
220 … 240
VBC7 mini reversing contactors
5.5
12
5
600 V /
16 A
12
24
48
60
110 ... 125
220 … 240
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VBC6-30-10-P-07
VBC6-30-01-P-07
VBC6-30-10-P-01
VBC6-30-01-P-01
VBC6-30-10-P-06
VBC6-30-06-P-06
VBC6-30-10-P-03
VBC6-30-01-P-03
VBC6-30-10-P-04
VBC6-30-01-P-04
VBC6-30-10-P-05
VBC6-30-01-P-05
GJL1213909R0107
GJL1213909R0017
GJL1213909R0101
GJL1213909R0011
GJL1213909R0106
GJL1213909R0016
GJL1213909R0103
GJL1213909R0013
GJL1213909R0104
GJL1213909R0014
GJL1213909R0105
GJL1213909R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VBC7-30-10-P-07
VBC7-30-01-P-07
VBC7-30-10-P-01
VBC7-30-01-P-01
VBC7-30-10-P-16
VBC7-30-01-P-16
VBC7-30-10-P-03
VBC7-30-01-P-03
VBC7-30-10-P-04
VBC7-30-01-P-04
VBC7-30-10-P-05
VBC7-30-01-P-05
GJL1313909R0107
GJL1313909R0017
GJL1313909R0101
GJL1313909R0011
GJL1313909R1106
GJL1313909R1016
GJL1313909R0103
GJL1313909R0013
GJL1313909R0104
GJL1313909R0014
GJL1313909R0105
GJL1313909R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
mm, inches
47.7 1.88"
3/22 | ABB
0.18"
2CDC102026C0201
1 0.04"
42.2 1.66"
45.2 1.78"
4.5
VBC6, VBC7
4.3 0.17"
44.7 1.76"
96.2 3.79"
2CDC212007F0011
Main dimensions
57.5 2.26"
3
VBC6, VBC7 3-pole compact design reversing contactors are space optimized control products mainly
used for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for soldering on PCB boards
VB6A, VB7A 3-pole mini reversing contactors – with soldering pins
4 to 5.5 kW
AC operated – with safety blocking function
3
Ordering details
IEC
Rated operational
power current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit Auxiliary Type
contacts
3-phase General voltage
UC
fitted
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
V AC
Order code
Pkg Weight
qty (1 pce)
V AC
kg
VB6A mini reversing contactors with safety blocking function
4
12
3
300 V / 24
24
1
12 A
0
42
42
1
0
48
48
1
0
110 … 127 110 … 127 1
0
220 … 240 220 … 240 1
0
380 … 415 380 … 415 1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB6A-30-10-P-01
VB6A-30-01-P-01
VB6A-30-10-P-02
VB6A-30-01-P-02
VB6A-30-10-P-03
VB6A-30-01-P-03
VB6A-30-10-P-84
VB6A-30-01-P-84
VB6A-30-10-P-80
VB6A-30-01-P-80
VB6A-30-10-P-85
VB6A-30-01-P-85
GJL1211919R0101
GJL1211919R0011
GJL1211919R0102
GJL1211919R0012
GJL1211919R0103
GJL1211919R0013
GJL1211919R8104
GJL1211919R8014
GJL1211919R8100
GJL1211919R8010
GJL1211919R8105
GJL1211919R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
VB7A mini reversing contactors with safety blocking function
5.5
12
5
600 V / 24
24
1
16 A
0
42
42
1
0
48
48
1
0
110 … 127 110 … 127 1
0
220 … 240 220 … 240 1
0
380 … 415 380 … 415 1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB7A-30-10-P-01
VB7A-30-01-P-01
VB7A-30-10-P-02
VB7A-30-01-P-02
VB7A-30-10-P-03
VB7A-30-01-P-03
VB7A-30-10-P-84
VB7A-30-01-P-84
VB7A-30-10-P-80
VB7A-30-01-P-80
VB7A-30-10-P-85
VB7A-30-01-P-85
GJL1311919R0101
GJL1311919R0011
GJL1311919R0102
GJL1311919R0012
GJL1311919R0103
GJL1311919R0013
GJL1311919R8104
GJL1311919R8014
GJL1311919R8100
GJL1311919R8010
GJL1311919R8105
GJL1311919R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
mm, inches
47.7 1.88"
4.3 0.17"
44.7 1.76"
1 0.04"
42.2 1.66"
96.2 3.79"
0.18"
2CDC102027C0201
4.5
2CDC212007F0011
Main dimensions
45.2 1.78"
VB7-30-01-P
VB6A, VB7A 3-pole compact design reversing contactors are space optimized control products mainly
used for switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the
voltage is applied to the coil of the contactor to be switched on before the contactor to be switched
off has dropped out. The contactor coils are designed for continuous operation when the contactor is
de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor
with the coil voltage applied.
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for soldering on PCB boards
57.5 2.26"
2CDC211013F0010
Description
VB6A, VB7A
ABB | 3/23
VBC7A 3-pole mini reversing contactors – with soldering pins
4 to 5.5 kW
DC operated – with safety blocking function
2CDC211009F0011
Description
VBC7A-30-10-P
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
kg
VBC7A mini reversing contactors with safety blocking function
5.5
12
5
600 V / 12
1 0 VBC7A-30-10-P-07
16 A
0 1 VBC7A-30-01-P-07
24
1 0 VBC7A-30-10-P-01
0 1 VBC7A-30-01-P-01
48
1 0 VBC7A-30-10-P-16
0 1 VBC7A-30-01-P-16
60
1 0 VBC7A-30-10-P-03
0 1 VBC7A-30-01-P-03
110 ... 125
1 0 VBC7A-30-10-P-04
0 1 VBC7A-30-01-P-04
220 … 240
1 0 VBC7A-30-10-P-05
0 1 VBC7A-30-01-P-05
GJL1313919R0107
GJL1313919R0017
GJL1313919R0101
GJL1313919R0011
GJL1313919R1106
GJL1313919R1016
GJL1313919R0103
GJL1313919R0013
GJL1313919R0104
GJL1313919R0014
GJL1313919R0105
GJL1313919R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
mm, inches
47.7 1.88"
3/24 | ABB
0.18"
2CDC102028C0201
1 0.04"
42.2 1.66"
45.2 1.78"
4.5
VBC7A
4.3 0.17"
44.7 1.76"
96.2 3.79"
2CDC212007F0011
Main dimensions
57.5 2.26"
3
VBC7A 3-pole compact design reversing contactors are space optimized control products mainly used for
switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the
voltage is applied to the coil of the contactor to be switched on before the contactor to be switched
off has dropped out. The contactor coils are designed for continuous operation when the contactor is
de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor
with the coil voltage applied.
– – control circuit: AC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for soldering on PCB boards
K6 4-pole mini contactor relays – with soldering pins
AC operated
3
Ordering details
Rated control circuit voltage
UC
50 Hz
V AC
Type
Order code
Pkg Weight
qty (1 pce)
60 Hz
V AC
kg
K6 4-pole mini contactor relays
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
K6-22Z-P-01
K6-22Z-P-02
K6-22Z-P-03
K6-22Z-P-84
K6-22Z-P-80
K6-22Z-P-85
K6-31Z-P-01
K6-31Z-P-02
K6-31Z-P-03
K6-31Z-P-84
K6-31Z-P-80
K6-31Z-P-85
K6-40E-P-01
K6-40E-P-02
K6-40E-P-03
K6-40E-P-84
K6-40E-P-80
K6-40E-P-85
GJH1211009R0221
GJH1211009R0222
GJH1211009R0223
GJH1211009R8224
GJH1211009R8220
GJH1211009R8225
GJH1211009R0311
GJH1211009R0312
GJH1211009R0313
GJH1211009R8314
GJH1211009R8310
GJH1211009R8315
GJH1211009R0401
GJH1211009R0402
GJH1211009R0403
GJH1211009R8404
GJH1211009R8400
GJH1211009R8405
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
mm, inches
47.7 1.88"
4.3 0.17"
44.7 1.76"
2CDC102030C0201
2CDC212003F0011
47.5 1.87"
1 0.04"
Main dimensions
42.2 1.66"
K6-22Z-P
K6 4-pole mini-contactor relays are space optimized control products mainly used for control functions or
for small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact block for side mounting
–– designed for soldering on PCB boards
45.2 1.78"
2CDC211022F0011
Description
K6
ABB | 3/25
KC6 4-pole mini contactor relays – with soldering pins
DC operated
2CDC211025F0011
Description
KC6-22Z-P
Ordering details
2CDC211023F0011
KC6-31Z-P
Rated control circuit voltage
UC
Type
Order code
Pkg Weight
qty (1 pce)
V DC
kg
K6 4-pole mini contactor relays
12
24
48
110 ... 125
220 ... 240
24
48
110 ... 125
220 ... 240
12
24
48
110 ... 125
220 ... 240
KC6-22Z-P-07
KC6-22Z-P-01
KC6-22Z-P-16
KC6-22Z-P-04
KC6-22Z-P-05
KC6-31Z-P-01
KC6-31Z-P-16
KC6-31Z-P-04
KC6-31Z-P-05
KC6-40E-P-07
KC6-40E-P-01
KC6-40E-P-16
KC6-40E-P-04
KC6-40E-P-05
GJH1213009R0227
GJH1213009R0221
GJH1213009R1226
GJH1213009R0224
GJH1213009R0225
GJH1213009R0311
GJH1213009R1316
GJH1213009R0314
GJH1213009R0315
GJH1213009R0407
GJH1213009R0401
GJH1213009R1406
GJH1213009R0404
GJH1213009R0405
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
mm, inches
47.7 1.88"
3/26 | ABB
2CDC102031C0201
KC6
4.3 0.17"
44.7 1.76"
2CDC212003F0011
42.2 1.66"
47.5 1.87"
1 0.04"
Main dimensions
45.2 1.78"
3
KC6 4-pole mini-contactor relays are space optimized control products mainly used for control functions
or for small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact block for side mounting
–– designed for soldering on PCB boards
BC6, BC7 3-pole interface mini contactors – with soldering pins
4 to 5.5 kW
DC operated
3
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
DC operation 24 V / 1.4 W
4
12
3
0
BC6-30-10-P-1.4-81
GJL1213009R8101
10
0.170
0
1
BC6-30-01-P-1.4-81
GJL1213009R8011
10
0.170
1
0
BC7-30-10-P-1.4-81
GJL1313009R8101
10
0.170
0
1
BC7-30-01-P-1.4-81
GJL1313009R8011
10
0.170
DC operation 17 … 32 V / 2.4 W, Ith < 8 A
4
12
3
300 V / 17 ... 32
12 A
1
0
BC6-30-10-P-2.4-51
GJL1213009R5101
10
0.170
0
1
BC6-30-01-P-2.4-51
GJL1213009R5011
10
0.170
5.5
1
0
BC7-30-10-P-2.4-51
GJL1313009R5101
10
0.170
0
1
BC7-30-01-P-2.4-51
GJL1313009R5011
10
0.170
5.5
12
12
5
5
300 V /
12 A
24
600 V /
16 A
24
kg
1
600 V /
16 A
17 ... 32
Other types on request
mm, inches
47.7 1.88"
4.3 0.17"
44.7 1.76"
2CDC102029C0201
2CDC212003F0011
47.5 1.87"
1 0.04"
Main dimensions
42.2 1.66"
BC7-30-10-P
BC6, BC7 3-pole interface mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.
These contactors are designed with:
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated
– – low coil consumption (1.4 ... 2.4 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for soldering on PCB boards
45.2 1.78"
2CDC211030F0011
Description
BC6, BC7
ABB | 3/27
KC6 4-pole interface mini contactor relays – with solderings pins
DC operated
2CDC211023F0011
Description
KC6-31Z-P-1.4
Ordering details
Rated control circuit voltage
UC
Type
Order code
Pkg Weight
qty (1 pce)
V DC
kg
DC operation 24 V / 1.4 W
24
24
KC6-31Z-P-1.4-81
KC6-40E-P-1.4-81
GJH1213009R8311
GJH1213009R8401
10
10
0.170
0.170
DC operation 17 ... 32 V / 2.4 W
17 ... 32
17 ... 32
KC6-31Z-P-2.4-51
KC6-40E-P-2.4-51
GJH1213009R5311
GJH1213009R5401
10
10
0.170
0.170
Other types on request
mm, inches
47.7 1.88"
3/28 | ABB
2CDC102032C0201
KC6
4.3 0.17"
44.7 1.76"
2CDC212003F0011
42.2 1.66"
47.5 1.87"
1 0.04"
Main dimensions
45.2 1.78"
3
KC6 4-pole interface mini-contactor relays are space optimized control products mainly used for control
functions or for small loads up to 4 A.
These contactors are designed with:
– – 4-poles with various contact combinations
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact block for side mounting
–– designed for soldering on PCB boards
B6, B7 3-pole mini contactors – with flat pin connection
4 to 5.5 kW
AC operated
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit
3-phase General voltage
UC
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
B6 mini contactors
4
20
3
300 V /
12 A
V AC
V AC
24
24
42
42
48
48
220 … 240 220 … 240
380 … 415 380 … 415
B7 mini contactors
5.5
20
5
600 V /
16 A
24
24
42
42
48
48
Auxiliary Type
contacts
fitted
Order code
Pkg Weight
qty (1 pce)
kg
110 … 127 110 … 127
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
B6-30-10-F-01
B6-30-01-F-01
B6-30-10-F-02
B6-30-01-F-02
B6-30-10-F-03
B6-30-01-F-03
B6-30-10-F-84
B6-30-01-F-84
B6-30-10-F-80
B6-30-01-F-80
B6-30-10-F-85
B6-30-01-F-85
GJL1211003R0101
GJL1211003R0011
GJL1211003R0102
GJL1211003R0012
GJL1211003R0103
GJL1211003R0013
GJL1211003R8104
GJL1211003R8014
GJL1211003R8100
GJL1211003R8010
GJL1211003R8105
GJL1211003R8015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
B7-30-10-F-01
B7-30-01-F-01
B7-30-10-F-02
B7-30-01-F-02
B7-30-10-F-03
B7-30-01-F-03
B7-30-10-F-84
B7-30-01-F-84
B7-30-10-F-80
B7-30-01-F-80
B7-30-10-F-85
B7-30-01-F-85
GJL1311003R0101
GJL1311003R0011
GJL1311003R0102
GJL1311003R0012
GJL1311003R0103
GJL1311003R0013
GJL1311003R8104
GJL1311003R8014
GJL1311003R8100
GJL1311003R8010
GJL1311003R8105
GJL1311003R8015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7
1.84"
43.7
4.5 0.18"
1.72"
2CDC102033C0201
52.5
2CDC212002F0011
Main dimensions
2.26"
B7-30-10-F
3
Ordering details
45.2
2CDC211031F0011
B6-30-10-F
B6..F, B7..F 3-pole mini contactors are compact control products mainly used for switching resistive or
motor loads up to 690 V AC.
These contactors are designed with:
– – flat pin connection for plug-in wiring and shake proven connection
– – 3 main poles and one built-in auxiliary contact
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
–– hum-free coil
–– add-on auxiliary contact blocks for side mounting
–– designed for rail or wall mounting
57.5
2CDC211002F0010
Description
B6, B7
ABB | 3/29
BC6, BC7 3-pole mini contactors – with flat pin connection
4 to 5.5 kW
DC operated
2CDC211041F0011
Description
BC6-30-10-F
2CDC211024F0011
BC7-30-10-F
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control
3-phase General circuit voltage
UC
motor use
rating
rating
480 V
hp
Auxiliary Type
contacts
fitted
Order code
Pkg Weight
qty (1 pce)
V DC
BC6 mini contactors
4
20
3
300 V /
12 A
kg
12
24
48
60
110 … 125
220 … 240
BC7 mini contactors
5.5
20
5
600 V /
16 A
12
24
48
60
110 … 125
220 … 240
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
BC6-30-10-F-07
BC6-30-01-F-07
BC6-30-10-F-01
BC6-30-01-F-01
BC6-30-10-F-16
BC6-30-01-F-16
BC6-30-10-F-03
BC6-30-01-F-03
BC6-30-10-F-04
BC6-30-01-F-04
BC6-30-10-F-05
BC6-30-01-F-05
GJL1213003R0107
GJL1213003R0017
GJL1213003R0101
GJL1213003R0011
GJL1213003R1106
GJL1213003R1016
GJL1213003R0103
GJL1213003R0013
GJL1213003R0104
GJL1213003R0014
GJL1213003R0105
GJL1213003R0015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
BC7-30-10-F-07
BC7-30-01-F-07
BC7-30-10-F-01
BC7-30-01-F-01
BC7-30-10-F-16
BC7-30-01-F-16
BC7-30-10-F-03
BC7-30-01-F-03
BC7-30-10-F-04
BC7-30-01-F-04
BC7-30-10-F-05
BC7-30-01-F-05
GJL1313003R0107
GJL1313003R0017
GJL1313003R0101
GJL1313003R0011
GJL1313003R1106
GJL1313003R1016
GJL1313003R0103
GJL1313003R0013
GJL1313003R0104
GJL1313003R0014
GJL1313003R0105
GJL1313003R0015
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7
1.84"
43.7
4.5 0.18"
BC6, BC7
3/30 | ABB
1.72"
2CDC102034C0201
52.5
2CDC212002F0011
Main dimensions
57.5
3
BC6, BC7 3-pole mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.
These contactors are designed with:
– – flat pin connection for plug-in wiring and shake proven connection
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for side mounting
–– designed for rail or wall mounting
VB7 3-pole mini reversing contactors – with flat pin connection
4 to 5.5 kW
AC operated
3
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit Auxiliary Type
contacts
3-phase General voltage
UC
fitted
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
VB7 mini reversing contactors
5.5
20
5
600 V /
16 A
V AC
V AC
24
24
42
42
48
48
110 … 127 110 … 127
220 … 240 220 … 240
380 … 415 380 … 415
Order code
Pkg Weight
qty (1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VB7-30-10-F-01
VB7-30-01-F-01
VB7-30-10-F-02
VB7-30-01-F-02
VB7-30-10-F-03
VB7-30-01-F-03
VB7-30-10-F-84
VB7-30-01-F-84
VB7-30-10-F-80
VB7-30-01-F-80
VB7-30-10-F-85
VB7-30-01-F-85
GJL1311903R0101
GJL1311903R0011
GJL1311903R0102
GJL1311903R0012
GJL1311903R0103
GJL1311903R0013
GJL1311903R8104
GJL1311903R8014
GJL1311903R8100
GJL1311903R8010
GJL1311903R8105
GJL1311903R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
Main dimensions
mm, inches
46.7 1.84"
43.7 1.72"
2CDC102035C0201
4.5 0.18"
2CDC212006F0011
42.2 1.66"
96.2 3.79"
45.2 1.78"
VB7-30-10-F
VB7 3-pole compact design reversing contactors are space optimized control products mainly used for
switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc.
– – flat pin connection for plug-in wiring and shake proven connection
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– for rail and wall mounting
57.5 2.26"
2CDC211005F0011
Description
VB7
ABB | 3/31
VBC7 3-pole mini reversing contactors – with flat pin connection
4 to 5.5 kW
DC operated
2CDC211004F0011
Description
VBC7-30-10-F
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
VBC7 mini reversing contactors
5.5
20
5
600 V /
16 A
12
24
48
60
110 ... 125
220 … 240
kg
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
VBC7-30-10-F-07
VBC7-30-01-F-07
VBC7-30-10-F-01
VBC7-30-01-F-01
VBC7-30-10-F-16
VBC7-30-01-F-16
VBC7-30-10-F-03
VBC7-30-01-F-03
VBC7-30-10-F-04
VBC7-30-01-F-04
VBC7-30-10-F-05
VBC7-30-01-F-05
GJL1313903R0107
GJL1313903R0017
GJL1313903R0101
GJL1313903R0011
GJL1313903R1106
GJL1313903R1016
GJL1313903R0103
GJL1313903R0013
GJL1313903R0104
GJL1313903R0014
GJL1313903R0105
GJL1313903R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
Main dimensions
mm, inches
46.7 1.84"
43.7 1.72"
VBC7
3/32 | ABB
2CDC102036C0201
4.5 0.18"
2CDC212006F0011
42.2 1.66"
45.2 1.78"
96.2 3.79"
57.5 2.26"
3
VBC7 3-pole compact design reversing contactors are space optimized control products mainly used for
switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock. The coils must be mutually interlocked electrically and coils must be deenergised for 50 ms at least to prevent phase to phase short circuit on the arc
– – flat pin connection for plug-in wiring and shake proven connection
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– for rail and wall mounting
VB7A 3-pole mini reversing contactors – with flat pin connection
4 to 5.5 kW
AC operated – with safety blocking function
3
Ordering details
IEC
Rated operational
power current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control circuit Auxiliary Type
contacts
3-phase General voltage
UC
fitted
motor use
rating
rating
480 V
50 Hz
60 Hz
hp
V AC
Order code
V AC
VB7A mini reversing contactors with safety blocking function
5.5
20
5
600 V / 24
24
1
16 A
0
42
42
1
0
48
48
1
0
110 … 127 110 … 127 1
0
220 … 240 220 … 240 1
0
380 … 415 380 … 415 1
0
Pkg Weight
qty (1 pce)
pce kg
0
1
0
1
0
1
0
1
0
1
0
1
VB7A-30-10-F-01
VB7A-30-01-F-01
VB7A-30-10-F-02
VB7A-30-01-F-02
VB7A-30-10-F-03
VB7A-30-01-F-03
VB7A-30-10-F-84
VB7A-30-01-F-84
VB7A-30-10-F-80
VB7A-30-01-F-80
VB7A-30-10-F-85
VB7A-30-01-F-85
GJL1311913R0101
GJL1311913R0011
GJL1311913R0102
GJL1311913R0012
GJL1311913R0103
GJL1311913R0013
GJL1311913R8104
GJL1311913R8014
GJL1311913R8100
GJL1311913R8010
GJL1311913R8105
GJL1311913R8015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
Main dimensions
mm, inches
46.7 1.84"
43.7 1.72"
2CDC102037C0201
4.5 0.18"
2CDC212006F0011
42.2 1.66"
96.2 3.79"
45.2 1.78"
VB7A-30-10-F
VB7A 3-pole compact design reversing contactors are space optimized control products mainly used for
switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the
voltage is applied to the coil of the contactor to be switched on before the contactor to be switched
off has dropped out. The contactor coils are designed for continuous operation when the contactor is
de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor
with the coil voltage applied.
– – flat pin connection for plug-in wiring and shake proven connection
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– for rail and wall mounting
57.5 2.26"
2CDC211003F0011
Description
VB7A
ABB | 3/33
VBC7A 3-pole mini reversing contactors – with flat pin connection
4 to 5.5 kW
DC operated – with safety blocking function
2CDC211002F0011
Description
VBC7A-30-10-F
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
Order code
Pkg Weight
qty (1 pce)
V DC
kg
VBC7A mini reversing contactors with safety blocking function
5.5
20
5
600 V / 12
1 0 VBC7A-30-10-F-07
16 A
0 1 VBC7A-30-01-F-07
24
1 0 VBC7A-30-10-F-01
0 1 VBC7A-30-01-F-01
48
1 0 VBC7A-30-10-F-16
0 1 VBC7A-30-01-F-16
60
1 0 VBC7A-30-10-F-03
0 1 VBC7A-30-01-F-03
110 ... 125
1 0 VBC7A-30-10-F-04
0 1 VBC7A-30-01-F-04
220 … 240
1 0 VBC7A-30-10-F-05
0 1 VBC7A-30-01-F-05
GJL1313913R0107
GJL1313913R0017
GJL1313913R0101
GJL1313913R0011
GJL1313913R1106
GJL1313913R1016
GJL1313913R0103
GJL1313913R0013
GJL1313913R0104
GJL1313913R0014
GJL1313913R0105
GJL1313913R0015
5
5
5
5
5
5
5
5
5
5
5
5
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.345
Other types on request
Main dimensions
mm, inches
46.7 1.84"
43.7 1.72"
VBC7A
3/34 | ABB
2CDC102038C0201
4.5 0.18"
2CDC212006F0011
42.2 1.66"
45.2 1.78"
96.2 3.79"
57.5 2.26"
3
VBC7A 3-pole compact design reversing contactors are space optimized control products mainly used for
switching resistive or motor loads up to 690 V AC.
These reversing contactors are designed with:
– – built-in mechanical interlock and safety blocking function. The safety blocking function is triggered if the
voltage is applied to the coil of the contactor to be switched on before the contactor to be switched
off has dropped out. The contactor coils are designed for continuous operation when the contactor is
de-energised i.e. the coil is not damaged if the mechanical interlock prevents switch-on of the contactor
with the coil voltage applied.
– – flat pin connection for plug-in wiring and shake proven connection
– – control circuit: DC operated
– – low coil consumption (3.5 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– for rail and wall mounting
BC6, BC7 3-pole interface mini contactors – with flat pin connection
4 to 5.5 kW
DC operated
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL/CSA
Rated control Auxiliary Type
3-phase General circuit voltage contacts
UC
fitted
motor use
rating
rating
480 V
hp
5.5
20
5
300 V /
12 A
24
600 V /
16 A
24
DC operation 17 … 32 V / 2.4 W
4
20
3
300 V /
12 A
17 ... 32
5.5
17 ... 32
20
Order code
Pkg Weight
qty (1 pce)
V DC
DC operation 24 V / 1.4 W
4
20
3
5
600 V /
16 A
kg
1
0
1
0
0
1
0
1
BC6-30-10-F-1.4-81
BC6-30-01-F-1.4-81
BC7-30-10-F-1.4-81
BC7-30-01-F-1.4-81
GJL1213003R8101
GJL1213003R8011
GJL1313003R8101
GJL1313003R8011
10
10
10
10
0.170
0.170
0.170
0.170
1
0
1
0
0
1
0
1
BC6-30-10-F-2.4-51
BC6-30-01-F-2.4-51
BC7-30-10-F-2.4-51
BC7-30-01-F-2.4-51
GJL1213003R5101
GJL1213003R5011
GJL1313003R5101
GJL1313003R5011
10
10
10
10
0.170
0.170
0.170
0.170
Other types on request
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7
1.84"
43.7
4.5 0.18"
1.72"
2CDC102039C0201
52.5
2CDC212002F0011
Main dimensions
2.26"
BC7-30-10-F
3
Ordering details
45.2
2CDC211024F0011
BC6-30-10-F
BC6, BC7 3-pole interface mini contactors are compact control products mainly used for switching resistive or motor loads up to 690 V AC.
These contactors are designed with:
– – flat pin connection for plug-in wiring and shake proven connection
– – 3 main poles and one built-in auxiliary contact
– – control circuit: DC operated
– – low coil consumption (1.4 ... 2.4 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– designed for rail or wall mounting
57.5
2CDC211041F0011
Description
BC6, BC7
ABB | 3/35
K6 4-pole mini contactor relays – with flat pin connection
AC operated
2CDC211034S0011
Description
K6-22Z-F
Ordering details
Rated control circuit voltage
UC
Type
50 Hz
60 Hz
V AC
V AC
Order code
Pkg Weight
qty (1 pce)
kg
K6 4-pole mini contactor relays
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
24
24
42
42
48
48
110 ...127
110 ...127
220 ... 240
220 ... 240
380 ... 415
380 ... 415
K6-22Z-F-01
K6-22Z-F-02
K6-22Z-F-03
K6-22Z-F-84
K6-22Z-F-80
K6-22Z-F-85
K6-31Z-F-01
K6-31Z-F-02
K6-31Z-F-03
K6-31Z-F-84
K6-31Z-F-80
K6-31Z-F-85
K6-40E-F-01
K6-40E-F-02
K6-40E-F-03
K6-40E-F-84
K6-40E-F-80
K6-40E-F-85
GJH1211003R0221
GJH1211003R0222
GJH1211003R0223
GJH1211003R8224
GJH1211003R8220
GJH1211003R8225
GJH1211003R0311
GJH1211003R0312
GJH1211003R0313
GJH1211003R8314
GJH1211003R8310
GJH1211003R8315
GJH1211003R0401
GJH1211003R0402
GJH1211003R0403
GJH1211003R8404
GJH1211003R8400
GJH1211003R8405
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7
1.84"
43.7
4.5 0.18"
K6
3/36 | ABB
1.72"
2CDC102040C0201
52.5
2CDC212002F0011
Main dimensions
57.5
3
K6 4-pole mini-contactor relays are space optimized control products mainly used for control functions or
for small loads up to 4 A.
These contactors are designed with:
– – flat pin connection for plug-in wiring and shake proven connection
– – 4-poles with various contact combinations
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for side mounting
–– for rail and wall mounting
–– add-on auxiliary contact blocks for side mounting
KC6 4-pole mini contactor relays – with flat pin connection
DC operated
3
Ordering details
Rated control circuit voltage
UC
Type
Order code
Pkg Weight
qty (1 pce)
V DC
kg
K6 4-pole mini contactor relays
12
24
48
110 ... 125
220 ... 240
12
24
48
110 ... 125
220 ... 240
24
48
110 ... 125
220 ... 240
KC6-22Z-F-07
KC6-22Z-F-01
KC6-22Z-F-16
KC6-22Z-F-04
KC6-22Z-F-05
KC6-31Z-F-07
KC6-31Z-F-01
KC6-31Z-F-16
KC6-31Z-F-04
KC6-31Z-F-05
KC6-40E-F-01
KC6-40E-F-16
KC6-40E-F-04
KC6-40E-F-05
GJH1213003R0227
GJH1213003R0221
GJH1213003R1226
GJH1213003R0224
GJH1213003R0225
GJH1213003R0317
GJH1213003R0311
GJH1213003R1316
GJH1213003R0314
GJH1213003R0315
GJH1213003R0401
GJH1213003R1406
GJH1213003R0404
GJH1213003R0405
10
10
10
10
10
10
10
10
10
10
10
10
10
10
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Other types on request
2.26"
1.78"
1.66"
42.2
47.5
mm, inches
2.07"
1.87"
46.7
1.84"
43.7
4.5 0.18"
1.72"
2CDC102041C0201
52.5
2CDC212002F0011
Main dimensions
45.2
KC6-22Z-F-01
K6 4-pole mini-contactor relays are space optimized control products mainly used for control functions or
for small loads up to 4 A.
These contactors are designed with:
– – flat pin connection for plug-in wiring and shake proven connection
– – 4-poles with various contact combinations
– – control circuit: AC operated
– – low coil consumption (3.5 VA at pull-in and at holding)
– – hum-free coil
–– add-on auxiliary contact blocks for side mounting
–– for rail and wall mounting
57.5
2CDC211029F0011
Description
KC6
ABB | 3/37
KC6 4-pole interface mini contactor relays – with flat pin connection
DC operated
2CDC211033F0011
Description
KC6-31Z-F-05
Ordering details
Rated control circuit voltage
UC
Type
Order code
Pkg Weight
qty (1 pce)
V DC
kg
DC operation 24 V / 1.4 W
24
24
KC6-31Z-F-1.4-81
KC6-40E-F-1.4-81
GJH1213003R8311
GJH1213003R8401
10
10
0.170
0.170
DC operation 17 ... 32 V / 2.4 W
17 ... 32
17 ... 32
KC6-31Z-F-51
KC6-40E-F-51
GJH1213003R5311
GJH1213003R5401
10
10
0.170
0.170
Other types on request
2.26"
1.78"
1.66"
45.2
42.2
47.5
mm, inches
2.07"
1.87"
46.7
1.84"
43.7
4.5 0.18"
KC6
3/38 | ABB
1.72"
2CDC102045C0201
52.5
2CDC212002F0011
Main dimensions
57.5
3
KC6 4-pole interface mini-contactor relays are space optimized control products mainly used for control
functions or for small loads up to 4 A.
These contactors are designed with:
– – flat pin connection for plug-in wiring and shake proven connection
– – 4-poles with various contact combinations
– – control circuit: AC operated
– – low coil consumption (1.4 ... 2.4 W at pull-in and at holding)
– – hum-free coil
–– no auxiliary contact block permitted for mounting
–– for rail and wall mounting
–– no add-on auxiliary contact blocks possible
B6, B7, BC6, BC7 3- and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3-pole mini reversing contactors
Accessories
2CDC211012F0010
Ordering details
Suitable for
Auxiliary Type
contacts
Order code
Pkg Weight
qty (1 pce)
kg
2CDC211007F0010
CAF6-11N
2CDC211008F0010
RV-BC6/250
2CDC211018F0011
CA6-11E
Front mounted instantaneous auxiliary contact blocks (not allowed for mounting on TBC, B6S, B7S, interface contactors) 1)
B6-, B7-40-00, BC6-, BC7-40-00
1 1 CAF6-11E
GJL1201330R0002
10
VB6, VB7, VBC6, VBC7, VB6A, VB7A
2 0 CAF6-20E
GJL1201330R0006
10
VBC6A, VBC7A
0 2 CAF6-02E
GJL1201330R0010
10
1 1 CAF6-11M
GJL1201330R0003
10
B6-, B7-30-10, BC6-, BC7-30-10
VB6, VB7, VBC6, VBC7, VB6A, VB7A
2 0 CAF6-20M
GJL1201330R0007
10
VBC6A, VBC7A
0 2 CAF6-02M
GJL1201330R0011
10
1 1 CAF6-11N
GJL1201330R0004
10
B6-, B7-30-01, BC6-, BC7-30-01
VB6, VB7, VBC6, VBC7, VB6A, VB7A
2 0 CAF6-20N
GJL1201330R0008
10
VBC6A, VBC7A
0 2 CAF6-02N
GJL1201330R0012
10
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
Side mounted instantaneous auxiliary contact block 1)
B6-, B7-40-00, BC6-, BC7-40-00
B6-, B7-30-10, BC6-, BC7-30-10
B6-, B7-30-01, BC6-, BC7-30-01
GJL1201317R0002
GJL1201317R0003
GJL1201317R0004
10
10
10
0.030
0.030
0.030
Side mounted instantaneous auxiliary contact block with soldering pins 2)
B6-, B7-40-00-P, BC6-,BC7-40-00-P
1 1 CA6-11E-P
B6-, B7-30-10-P, BC6-, BC7-30-10-P
1 1 CA6-11M-P
B6-, B7-30-01-P, BC6-, BC7-30-01-P
1 1 CA6-11N-P
GJL1201319R0002
GJL1201319R0003
GJL1201319R0004
10
10
10
0.025
0.025
0.025
Side mounted instantaneous auxiliary contact block with flat pin connection 2)
B6-, B7-40-00-F, BC6-,BC7-40-00-F
1 1 CA6-11E-F
B6-, B7-30-10-F, BC6-, BC7-30-10-F
1 1 CA6-11M-F
B6-, B7-30-01-F, BC6-, BC7-30-01-F
1 1 CA6-11N-F
GJL1201318R0002
GJL1201318R0003
GJL1201318R0004
10
10
10
0.025
0.025
0.025
Soldering receptacle (Ith = 10 A, AC-3: 500 V / 8 A, 690 V / 3.5 A, UL: 300 V / 8 A)
B6, B7, BC6, BC7
LB6
2-pole aux.contact blocks CA
LB6-CA
GJL1201902R0001
GJL1201903R0001
10
10
0.020
0.010
1)
CA6-11E-P
Rated control
circuit voltage UC
V DC
CA6-11E
CA6-11M
CA6-11N
Connection type
Type
Order code
Pkg Weight
qty (1 pce)
kg
Cable lug
Flat pin, 2.8 mm
Cable lug
Flat pin, 2.8 mm
Cable lug
Flat pin, 2.8 mm
RV-BC6/60
RV-BC6-F/60
RV-BC6/250
RV-BC6-F/250
RV-BC6/380
RV-BC6-F/380
GHV2501902R0002
GHV2501902R0003
GHV2501903R0002
GHV2501903R0003
GHV2501904R0002
GHV2501904R0003
10
10
10
10
10
10
0.005
0.005
0.005
0.010
0.005
0.010
BEA7/132
BEA7/325
1SBN080906R1002
1SBN080906R1001
10
10
0.013
0.021
BSM6-30
GJL1201908R0001
10
0.010
Parallel connecting link
B6, B7, BC6, BC7
LP6
GJL1201907R0001
100 0.009
Cover cap, transparent fitting to DIN rail design, sealable
B6, B7, BC6, BC7
LT6-B
GJL1201906R0001
10
0.015
Plastic label for markings
B6, B7, BC6, BC7
BA5-50
1SBN110000R1000
50
0.020
1
0.100
Surge suppressors for contactor coils
BC6, BC7
24 ... 60
2CDC211020F0011
1
1
1
CA6 and CAF6 must not be fitted simultaneously.
Suitable for
CA6-11E-F
1
1
1
3
50 ... 250
380
Connecting links with manual motor starters
To connect B..VB.. mini contactor to MS116, MS132
To connect B..VB.. mini contactors to MS325
Connection sets for reversing contactors
VB6, VB7, VBC6, VBC7, VB6A, VB7A, VBC6A, VBC7A,
cross-section 1.8 mm²
2CDC231012F0011
BSM6-30
Thermal overload relays
T16 (see page 2CDC106036C0201)
T16-16
ABB | 3/39
2CDC102042C0201
SST27792R
Note: Mini contactors for AC operation have an integrated protective circuit
K6, KC6 4-pole mini contactor relays
Accessories
2CDC211019F0011
Ordering details
CAF6-11K
2CDC211009F0010
3
CA6-11K
Suitable for
Auxiliary Type
contacts
kg
1
0
2
CAF6-11K
CAF6-20K
CAF6-02K
GJL1201330R0001
GJL1201330R0005
GJL1201330R0009
10
10
10
0.020
0.020
0.020
Side mounted instantaneous auxiliary contact block 1)
K6, KC6
1
CA6-11K
GJL1201317R0001
10
0.030
GJL1201319R0001
10
0.025
GJL1201318R0001
10
0.025
LB6
LB6-CA
GJL1201902R0001
GJL1201903R0001
10
10
0.020
0.010
Type
Order code
Pkg Weight
qty (1 pce)
1
Side mounted instantaneous auxiliary contact block with soldering pins 2)
K6..P, KC6..P
1 1 CA6-11K-P
Side mounted instantaneous auxiliary contact block with flat pin connection
K6..F, KC6..F
1 1 CA6-11K-F
1)
2)
CA6 and CAF6 must not be fitted simultaneously.
Suitable for
2CDC211011F0010
Pkg Weight
qty (1 pce)
Front mounted instantaneous auxiliary contact blocks 1)
K6, KC6
1
2
0
Soldering receptacle ( Ie < 8 A )
K6, KC6
2-pole auxiliary contact blocks CA
CA6-11K-P
Order code
Rated control
circuit voltage
UC
V DC
Surge suppressors for contactor coils
KC6
24 ... 60
50 ... 250
380
Connection type
kg
Cable lug
Flat pin, 2.8 mm
Cable lug
Flat pin, 2.8 mm
Cable lug
Flat pin, 2.8 mm
RV-BC6/60
RV-BC6-F/60
RV-BC6/250
RV-BC6-F/250
RV-BC6/380
RV-BC6-F/380
GHV2501902R0002
GHV2501902R0003
GHV2501903R0002
GHV2501903R0003
GHV2501904R0002
GHV2501904R0003
10
10
10
10
10
10
0.005
0.005
0.005
0.010
0.005
0.010
GJL1201906R0001
10
0.015
2CDC211010F0010
Note: Mini contactors for AC operation have an integrated protective circuit
Cover cap, transparent fitting to DIN rail design, sealable
K6, KC6
LT6-B
2CDC211006F0010
CA6-11K-F
RV-BC6/250
3/40 | ABB
2CDC102042C0201
2CDC211007F0010
LT6-B
B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors
Technical data
Main pole – Utilization characteristics according to IEC
Contactor types
AC operated
DC operated
Standards
Rated operational voltage Ue max
Rated frequency (without derating)
Conventional free-air thermal current lth
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C,
with conductor cross-sectional area
AC-1 Utilization category for air temperature close to contactor θ ≤ 40 °C
Ie / Rated operational current AC-1
Ue max ≤ 690 V, 50/60 Hz
220-230-240 V
380-400 V
440 V
500 V
690 V
AC-1 Utilization category for air temperature close to contactor θ ≤ 55 °C
Ie / Rated operational current AC-1
Ue max ≤ 690 V, 50/60 Hz
220-230-240 V
380-400 V
440 V
500 V
690 V
B6, VB6, VB6A
BC6, VBC6, VBC6A
IEC/EN 60947-1, IEC/EN 60947-4-1
690 V AC
DC or 50 / 60 Hz
Screw terminal types: 20 A
Flat pin types: 20 A
Soldering pin types: 12 A
B7, VB7, VB7A
BC7, TBC7, VBC7, VBC7A
3
Screw terminal types: 20 A
Flat pin types: 20 A
Soldering pin types: 12 A
Screw terminal types: 20 A
Flat pin types: 20 A
Soldering pin types: 12 A
Screw terminal types: 20 A
Flat pin types: 20 A
Soldering pin types: 12 A
12 A
6A
Screw terminal types: 16 A
Flat pin types: 16 A
Soldering pin types: 12 A
Screw terminal types: 16 A
Flat pin types: 16 A
Soldering pin types: 12 A
Screw terminal types: 16 A
Flat pin types: 16 A
Soldering pin types: 12 A
12 A
6A
AC-3 Utilization category for air temperature close to contactor θ ≤ 55 °C
Ie / Rated operational current AC-3
220 / 230 / 240 V
380 / 400 V
3-phase motors
440 V
M
3
500 V
690 V
Rated operational power AC-3
220-230-240 V
380-400 V
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
440 V
500 V
M
3
690 V
DC-1 Utilization category for air temperature close to contactor θ ≤ 55 °C
Ie / Rated operational current DC-1
DC-3 Utilization category for air temperature close to contactor θ ≤ 55 °C
Ie / Rated operational current DC-3
DC-5 Utilization category for air temperature close to contactor θ ≤ 55 °C
Ie / Rated operational current DC-5
11.8 / 11.3 / 10.8 A
12.1 / 11.5 A
10.1 A
9.2 A
3.8 A
3 kW
5.5 kW
5.5 kW
5.5 kW
3 kW
110 V 220 V -
4A
0.6 A
110 V 220 V -
1.5 A
0.25 A
110 V 220 V 10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
0.4 A
0.2 A
Type 1: 25 A / Type 2: 25 A
64 A
64 A
AC-1 300 cycles/h
AC-3 600 cycles/h
DC-1, DC-3, DC-5 600 cycles/h
10 s
at 400 V
96 A
96 A
2CDC102043C0201
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection device for contactors
without thermal O/L relay - motor protection excluded
Ue ≤ 500 V AC - fuse type gG
Rated short-time withstand current ICW
at 40 °C ambient temperature, in free air from a cold state
Maximum breaking capacity cos ϕ = 0.45
Maximum electrical switching frequency
8.9 / 8.5 / 8.1 A
8.9 / 8.5 A
7.4 A
6.8 A
3.8 A
2.2 kW
4 kW
4 kW
4 kW
3 kW
ABB | 3/41
B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors
Technical data
Main pole – Utilization characteristics according to UL/NEMA/CSA
Contactor types
Standards
Maximum operational voltage
UL/CSA general use rating
UL/CSA maximum 1-phase motor rating
Full load current
120 V AC
240 V AC
120 V AC
240 V AC
Horse power rating
UL/CSA maximum 3-phase motor rating
Full load current 1)
Horse power rating
1)
Resistive Heating
Incandescent Lamps
Fluorescent Lamps
Short-circuit protection device for contactors
without thermal overload relay - motor protection excluded
Fuse rating
Fuse type, 600 V
Maximum electrical switching frequency
For resitive loads AC-1
For motor loads AC-3
1)
200 / 208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200 / 208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
300 V per pole
300 V per pole
300 V per pole
600 V
600 V
B6, VB6, VB6A
BC6, VBC6, VBC6A
UL 508, CSA C22.2 N°14
600 V
12 A / 300 V
B7, VB7, VB7A
BC7, TBC7, VBC7, VBC7A
16 A / 600 V
5.8 A
4.9 A
0.25 hp
0.5 hp
13.8 A
10.0 A
0.75 hp
1.5 hp
4.8 / 4.6 A
6.8 A
4.8 A
1.7 A
1 hp
2 hp
3 hp
1 hp
8A
6A
8.4 A
7.8 / 10.6 A
9.6 A
7.6 A
6.1 A
2 / 3 hp
3 hp
5 hp
5 hp
8A
6A
8.4 A
40 A
Class J
300 cycles/h
600 cycles/h
For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
Contactor types
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL/CSA
Rated impulse withstand voltage Uimp
Ambient air temperature, close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Resistance to shock
acc. IEC 60068-2-27 and EN 60068-2-27
acc. to IEC/EN 60947-1 Annex. Q
Resistance to vibrations
acc. IEC 60068-2-27 and EN 60068-2-27
acc. to IEC/EN 60947-1 Annex. Q
B6, VB6, VB6A
BC6, VBC6, VBC6A
B7, VB7, VB7A
BC7, TBC7, VBC7, VBC7A
690 V
600 V
6 kV
-25 ... +50 °C
-25 ... +55 °C
-40 ... +80 °C
Acc. to IEC 60947-1 Annex Q
2000 m
107 operating cycles
Half-sine
15 g / 11 ms
Category E
Sinusoidal
5 g / 3 ... 150 Hz
Category E
2CDC102043C0201
3
AC operated
DC operated
3/42 | ABB
B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors
Technical data
Magnet system characteristics for B6, B7 contactors
Contactor types
Coil operating limits acc. to IEC 60947-4-1
AC control voltage
Rated control circuit voltage UC
Coil consumption
AC operated
AC supply
Average pull-in value
Average holding value
Drop-out voltage
B6, VB6
0.85 ... 1.1 x Uc
B7, VB7
See ordering tables
3.5 VA / 3.5 W
3.5 VA / 3.5 W
0.20 ... 0.75 % of Uc
3
Magnet system characteristics for BC6, BC7 contactors
Contactor types
Coil operating limits acc. to IEC 60947-4-1
AC control voltage
Rated control circuit voltage UC
Coil consumption 1)
DC operated
DC supply
Average pull-in value
Average holding value
Drop-out voltage in % of UC min
1)
BC6, VBC6
0.85 ... 1.1 x Uc
BC7, VBC7
See ordering tables
3.5 VA / 3.5 W
3.5 VA / 3.5 W
0.10 ... 0.75 x UC
Interface mini-contactors: see coil consumption on ordering details pages
Magnet system characteristics for TBC7 contactors
Contactor types
Coil operating limits acc. to IEC 60947-4-1
AC control voltage
Rated control circuit voltage UC
Coil consumption
DC operated
DC supply
Average pull-in value
Average holding value
Drop-out voltage in % of UC min
TBC7
Wide range voltage supply see ordering tables, UCmin ... UCmax
See ordering tables
5 VA / 5 W
5 VA / 5 W
≤ 0.20 % of UCmin
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
B6, VB6, VB6A
BC6, VBC6, VBC6A
Mounting positions
B7, VB7, VB7A
BC7, TBC7, VBC7, VBC7A
Pos. 2
+ 30°
- 30°
Pos. 4
Pos. 3
Pos. 1
Pos. 5
Pos. 6
The contactors can be assembled side by side
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
2CDC102043C0201
Mounting distances
Fixing
On rail acc. to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
ABB | 3/43
B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors
Technical data
Auxiliary contacts for front mounting, side mounting and built-in according to IEC
24 V 50/60 Hz
110-120 V 50/60 Hz
220-230-240 V 50/60 Hz
380-400 V 50/60 Hz
440 V 50/60 Hz
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
24 V DC
110 V DC
220 - 240 V DC
Short-circuit protection device
Minimum switching capacity with failure rate acc. to IEC 60947-5-4
Maximum electrical switching frequency
AC-15
DC-13
CA6, CAF6, built-in auxiliary contacts
IEC/EN 60947-1, IEC/EN 60947-4-1
690 V
DC or 50 / 60 Hz
6A
4A
4A
4A
3A
3A
2.5 A
0.7 A
0.4 A
6 A, Type gG
17 V / 5 mA
600 cycles/h
600 cycles/h
Auxiliary contacts for front mounting, side mounting and built-in according to UL/CSA
Types
Max. operational voltage
Pilot duty
AC thermal rated current
CA6, CAF6, built-in auxiliary contacts
600 V AC
A600
5A
Accessories for mini contactors
MO132
MS132
RV-BC6
MS116
BEA7
B7
B6
CAF6
CA6
RV-BC6
RV-BC6
T16
RV-BC6
3/44 | ABB
2CDC102043C0201
E16DU
2CDC212018F0011
3
Types
Standards
Rated operational voltage Ue max
Rated frequency (without derating)
Conventional free-air thermal current lth θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors
VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors
Technical data
Connection characteristics
Contactor types
AC operated
DC operated
B6, VB6, VB6A
BC6, VBC6, VBC6A
B7, VB7, VB7A
BC7, TBC7, VBC7, VBC7A
Main terminals 1)
Screw terminals with cable clamp
Connection capacity
Main conductors (poles)
Rigid: solid
Flexible without ferrule
Connection capacity acc. to UL/CSA
Stripping length
Tightening torques
Connection capacity – auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid: solid
Flexible without ferrule
Connection capacity acc. to UL/CSA
Stripping length
Tightening torques
Coil terminals
Built-in auxiliary terminals
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Built-in auxiliary terminals
Screw terminals
All terminals
Screwdriver type
1 or 2 x 1 ... 4 mm²
1 or 2 x 1 ... 2.5 mm²
1 or 2 x AWG 22 ... 10
9 mm
0.8 ... 1.1 Nm / 7 lb.in
0.8 ... 1.1 Nm / 7 lb.in
IP20
IP20
IP20
(Delivered in open position, screws of unused terminals must be tightened)
M3
Flat Ø 5.5 mm / Pozidriv 1
Soldering pin connection acc. to DIN 40801: 0.8 x 1 mm / 0.8 x 2.54 mm
Flat pin connection acc. to DIN 46248: 1 x 6.3 mm / 1 x 2.8 mm
2CDC102043C0201
1)
3
1 or 2 x 1 ... 4 mm²
1 or 2 x 1 ... 2.5 mm²
1 or 2 x AWG 22 ... 10
9 mm
0.8 ... 1.1 Nm / 7 lb.in
ABB | 3/45
K6, KC6, TKC6 4-pole mini contactor relays
Technical data
Main pole – Utilization characteristics according to IEC
Contactor types
24 V 50/60 Hz
110-120 V 50/60 Hz
220-230-240 V 50/60 Hz
380-400 V 50/60 Hz
440 V 50/60 Hz
480-500 V 50/60 Hz
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device for contactors Ue ≤ 500 V AC, fuse type gG
Minimum switching capacity
Maximum electrical switching frequency
24 V DC
110 V DC
220-240 V DC
AC-15
DC-13
K6
KC6, TKC6
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
690 V
DC or 50 / 60 Hz
6A
4A
4A
4A
3A
3A
2A
2.5 A
0.7 A
0.4 A
6A
17 V / 5 mA
600 cycles/h
600 cycles/h
Main pole – Utilization characteristics according to UL/NEMA/CSA
Contactor types
Standards
Maximum operational voltage
Pilot duty
AC operated
DC operated
K6
KC6, TKC6
UL 508, CSA C22.2 No14
600 V AC
A600
2CDC102043C0201
3
Standards
Rated operational voltage Uemax
Rated frequency (without derating)
Conventional free-air thermal current lth θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
AC operated
DC operated
3/46 | ABB
K6, KC6, TKC6 4-pole mini contactor relays
Technical data
General technical data
Contactor relay types
Rated insulation voltage Ui
acc. to IEC 60947-5-1
acc. to UL/CSA
Rated impulse withstand voltage Uimp
Electromagnetic compatibility
Ambient air temperature close to contactor relay
AC operated
DC operated
K6
KC6, TKC6
690 V
600 V
6 kV
Operation in free air
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Resistance to shock
acc. IEC 60068-2-27 and EN 60068-2-27
acc. to IEC/EN 60947-1 Annex. Q
Resistance to vibrations
acc. IEC 60068-2-27 and EN 60068-2-27
acc. to IEC/EN 60947-1 Annex. Q
3
-25 ... +55 °C
-40 ... +80 °C
Acc. to IEC 60068-2-30
2000 m
107 operating cycles
Half-sine
15 g / 11ms
Category E
Sinusoidal
5 g / 3 ... 150 Hz
Category E
Magnet system characteristics for K6 contactor relays
Contactor relay types
Coil operating limits acc. to IEC 60947-4-1
AC control voltage
Coil consumption Average pull-in value
Average holding value
Drop-out voltage in % of UC min.
AC operated
AC supply
K6
0.85 ... 1.1 x UC
3.5 VA / 3.5 W
3.5 VA / 3.5 W
Approx. 20 ... 75%
Contactor relay types
Coil operating limits acc. to IEC 60947-5-1
DC control voltage
Coil consumption Average pull-in value
Average holding value
Drop-out voltage in % of UC min.
DC operated
DC supply
KC6
0.85 ... 1.1 x UC
TKC6
See ordering details
3.5 VA / 3.5 W
3.5 VA / 3.5 W
10 ... 75 %
5 VA / 5 W
5 VA / 5 W
10 ... 75 %
2CDC102043C0201
Magnet system characteristics for KC6, TKC6 contactor relays
ABB | 3/47
K6, KC6, TKC6 4-pole mini contactor relays
Technical data
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
K6
KC6, TKC6
Mounting positions
Pos. 2
+ 30°
- 30°
Pos. 4
3
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Pos. 6
The contactors can be assembled side by side.
Mounting distances
Fixing
On rail acc. to IEC 60715, EN 60715
By screws (not supplied)
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
Connecting characteristics
Contactor relay types
AC operated
DC operated
K6
KC6, TKC6
Main terminals 1)
Screw terminals with cable clamp
Connection capacity
Main conductors (poles)
Rigid: solid
Flexible without ferrule
Connection apacity acc. to UL/CSA
Stripping length
Tightening torques
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All
Screw terminals
All terminals
Screwdriver type
IP20
(Delivered in open position, screws of unused terminals must be tightened)
M3
Flat Ø 5.5 / Pozidriv 1
Soldering pin connection acc. to DIN 40801: 0.8 x 1 mm / 0.8 x 2.54 mm
Flat pin connection acc. to DIN 46248: 1 x 6.3 mm / 1 x 2.8 mm
2CDC102043C0201
1)
1 or 2 x 1 ... 4 mm²
1 or 2 x 1 ... 2.5 mm²
1 or 2 x AWG 22 ... 10
9 mm
0.8 ... 1.1 Nm / 7 lb.in
3/48 | ABB
5
7
A1
2
4
6
8
A2
3
5 13 A1
2
4
6 14 A2
B6(7)-30-10 ...
BC6(7)-30-10 ...
3 R5 R7 A1
2
4 R6 R8 A2
B6(7)-22-00 ...
BC6(7)-22-00 ...
3
5 R7 A1
2
4
6 R8 A2
3
5
1
3
5 21 A1
A2 22 2
4
6
2
4
6 22 A2
3
5
1
3
5 13 A1
A2 14 2
4
6
2
4
6 14 A2
3
2CDC212009F0012
2CDC212008F0012
14 44 22 32 A2
2CDC212010F0012
13 43 21 31 A1
14 34 44 22 A2
K6-22Z ...
KC6-22Z ...
K6S-22Z ...
K6-31Z ...
KC6-31Z ...
K6S-31Z ...
14
53
54
31
32
61
62
4
6
8
1
3
5
13
➟
2
4
6
14
1
3
5
21
➟
2
4
6
40 E
➟
31 Z
22 Z
22
B(C)6(7)-30-10
B(C)6(7)-30-10-F
B(C)6(7)-30-10-P
B(C)6(7)-30-01
B(C)6(7)-30-01-F
B(C)6(7)-30-01-P
K(C)6 .....
K(C)6 ....-F
K(C)6 ....-P
B(C)6(7)-40-00
B(C)6(7)-30-10
B(C)6(7)-30-01
K(C)6 .....
1
3
5
7
13 21
13 23
11 21
14 22
14 24
12 22
CAF 6
2
4
1
3
6
8
5
13
1
2
3
33 21
23 33
21 31
34 22
24 34
22 32
CAF 6
2
4
1
3
6
14
5
21
1
2
3
13 31
13 33
11 31
14 32
14 34
12 32
CAF 6
2
4
6
40 E
22
1
2
3
53 61
53 63
51 61
54 62
54 64
52 62
2
3
31 Z
22 Z
1
1 = CAF6-11E
2 = CAF6-20E
3 = CAF6-02E
1 = CAF6-11M
2 = CAF6-20M
3 = CAF6-02M
1 = CAF6-11N
2 = CAF6-20N
3 = CAF6-02N
1 = CAF6-11K
2 = CAF6-20K
3 = CAF6-02K
2CDC212015F0012
2
B(C)6(7)-40-00
B(C)6(7)-40-00-F
B(C)6(7)-40-00-P
2CDC212016F0012
7
2CDC102043C0201
13
22
5
2CDC212017F0012
34
21
3
2CDC212018F0012
33
22
1
➟
2CDC212011F0012
14
21
2CDC212012F0012
13
2CDC212013F0012
CAF...
2CDC212014F0012
CA6...
CA6-11K
CA6-11K-F
CA6-11K-P
6 22 A2
A1 13 1
13 33 43 21 A1
K6-40E ...
KC6-40E ...
CA6-11N
CA6-11N-F
CA6-11N-P
4
VB6(7)-30-10 ...
VBC6(7)-30-10 ...
13 23 33 43 A1
CA6-11M
CA6-11M-F
CA6-11M-P
2
2CDC212007F0012
A1 21 1
CA6-11E
CA6-11E-F
CA6-11E-P
5 21 A1
B6(7)-31-00 ...
BC6(7)-31-00 ...
14 24 34 44 A2
Auxiliary switches
3
B6(7)-30-01 ...
BC6(7)-30-01 ...
1
VB6(7)-30-01 ...
VBC6(7)-30-01 ...
Mini contactor relays
1
2CDC212005F0012
1
2CDC212004F0012
B6(7)-40-00 ...
BC6(7)-40-00 ...
Compact reversing
contactors
1
2CDC212003F0012
3
2CDC212002F0012
1
2CDC212006F0012
Mini contactors
2CDC212001F0012
Mini contactors
Location of the connection terminals and terminal designation
ABB | 3/49
Summary_4
4
4/0 | ABB
AS contactors and
NS contactor relays with screw terminals
Overview 4/2
Motor starting solutions - open type version, in kit form
with screw terminals
4/5
3-pole contactors and contactor relays with screw terminals
4/29
4
4/84
Summary_4
Voltage code table
ABB | 4/1
Compact
Optimize your equipment dimensions!
One frame size for contactors up to 7.5 kW - 400 V
Same dimensions
for AC and DC operated contactors with screw
or spring terminals
4
Reversing contactors
including mechanical and electrical interlocking without
additional width
Direct control by PLC
removing any use of interface relay and reducing panel power
consumption
ide clipped-on surge suppressors
S
integrated into overall contactor dimensions allowing free
access to coil terminals
Multiple packaging available for all products
1SBC101277S0201
"Click"
4/2 | ABB
Simple
Choose reliable and time-saving solutions
Select compact starters:
– – Direct-on-line and reversing starters up to 7.5 kW – 400 V
–– Star-delta starters up to 11 KW – 400 V.
Protect your motors against short-circuits and overloads
– – Type 1 or type 2 coordination guaranteed between contactors and short-circuit protection devices (manual motor
starters or fuses)
Time/cost saving solutions with
–– Connection sets for reversing and star-delta starter
–– Easy, fast and secure assembly, fitting and wiring of components
–– Direct 35 mm rail mounting: no additional mounting plate
required
–– Easy installation and dismounting of contactors: no unwiring of manual motor starters.
4
Compliant to International standards
Complies with RoHS European directives
Make your control circuits safe
High reliability
for low signals
Mechanically linked
contacts according to
IEC 60947-5-1
Annex L 3.0
Mirror contact
according to
IEC 60947-4-1
Annex F 2.1
Time and space-saving solutions, suitable for your
applications
Escalators
Elevators
Conveyors
Compressors
Door control
Hvac
Pumps
Washing machines...
1SBC101277S0201
––
––
––
––
––
––
––
––
ABB | 4/3
Summary_4-1
4
4/4 | ABB
Motor starting solutions
Open type version, in kit form with screw terminals
Starters protected by manual motor starters
Overview
4/6
Direct-on-line starters
4/8
Reversing starters
4/12
Dimensions
4/16
Starters protected by thermal overload relays
Overview
4/6
4/18
Star-delta starters
4/22
Dimensions
4/26
4
Summary_4-1
Direct-on-line and reversing starters
ABB | 4/5
Motor starting solutions
Open type version, in kit form
Starters protected by manual motor starters
Direct-on-line starters
Reversing starters
I>
I>
MS116
Manual motor starter
MS116
Manual motor
starter
4
BEA16-3
Connecting link
BEA16-3
Connecting link
BER16C-3
Connection set
AS
ASL
Contactors
AS
ASL
Contactors
VM3
Mechanical
interlock unit
Starters protected by thermal overload relays
Direct-on-line starters
Reversing starters
Star-delta starters
BER16C-3
Connection set
L Δ
Y
BEY16C-3
Connection set
Timer
AS
ASL
Contactors
VM3
Mechanical
interlock unit
VM3
Mechanical
interlock unit
AS
ASL
Contactors
T16
Thermal overload relay
CA3
1-pole auxiliary
contact block
T16
Thermal overload relay
T16
Thermal overload relay
4/6 | ABB
1SBC101271S0201
AS
ASL
Contactors
Starters protected
by manual motor starters
Switching of 3-phase cage motors
Direct-on-line starters
Reversing starters
Rated power - AC-3, 400 V
0.06...7.5 kW
0.06...7.5 kW
Short-circuit current Iq
16 kA - 50 kA
16 kA - 50 kA
Coordination type
Type 1 & type 2
Type 1 & type 2
Manual motor starters
MS116
MS116
AC operated
AS09 ... AS16
AS09 ... AS16
DC operated
ASL09 ... ASL16
ASL09 ... ASL16
Switching of 3-phase cage motors
Direct-on-line starters
Reversing starters
Rated power - AC-3, 400 V
4...7.5 kW
4...7.5 kW
AC operated
AS09 ... AS16
AS09 ... AS16
DC operated
ASL09 ... ASL16
ASL09 ... ASL16
T16
T16
Contactors
4
Contactors
Thermal overload relays
Switching of 3-phase cage motors
Star-delta starters
Rated power - AC-3, 400 V
7.5...11 kW
Contactors
Thermal overload relays
AC operated
AS09 ... AS16
DC operated
ASL09 ... ASL16
1SBC101271S0201
Starters protected
by thermal overload relays
T16
ABB | 4/7
Direct-on-line starters protected by manual motor starters
With AS, ASL contactors - open type version in kit form
Application
I>
Full voltage direct-on-line starting for controlling three-phase asynchronous motors is a simple and
economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a
starting current 5.5 to 7 times nominal current.
I/In C/Cn
7
1SBC101030F0014
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
MS116 + BEA16-3 + AS16-30-10
2
C
1
0
10
30
60
80
100
Coordination types
The contactor and the manual motor starter control and protect motors against overload and short-circuits
according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of
service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts light welding is acceptable.
Main technical data
Standards
IEC 60947-4-1 / EN 60947-4-1
Rated operational voltage Ue max.
690 V - 50/60 Hz
Rated insulation voltage Ui according to IEC 60947-4-1 690 V
Switching frequency
≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time
≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting time
Ambient air temperature close to the device
≤ 55 °C
Degree of protection
IP20
Mounting positions
os. 2
Pos
+30°
-30°
Pos. 3
Pos. 4
Pos. 1
Pos. 1 ± 30°
Pos. 5
4/8 | ABB
1SBC101272S0201
4
6
Direct-on-line starters protected by manual motor starters
With AS, ASL contactors - open type version in kit form
Description
You can easily assemble a direct-on-line starter by using the BEA16-3 connecting
link 3-pole insulated. It is used to electrically and mechanically connect MS116
manual motor starter and AS or ASL contactors.
I>
MS116
Manual motor
starter
BEA16-3
Connecting link
Select now easily and quickly your starter in the following pages for coordination
type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA or Iq = 50 kA up to 7.5 kW.
For complete coordination tables with MS116 or MS132, please contact your ABB
local sales organization.
4
AS
ASL
Contactors
33
43
44
5/ L3
KM1:5/L3
34
3/ L2
1/ L1
Wiring diagrams
Us
33
KM1:5/L3
Q1
34
Us
33
Q1
34
Q1
O
KM1
14
14
I
13
5/ L3
3/ L2
1/ L1
13
KM1
I
A1
O
13
6/ T3
2/ T1
4/ T2
I> I> I>
Q1
KM1
44
KM1:3/L2
A1
Us
N
43
Q1
44
KM1
A2
43
A2
Us
N
14
6/ T3
4/ T2
2/ T1
A2
A1
KM1
KM1:3/L2
U1 V1 W1
M
Power circuit
AC local control
33
43
34
44
5/ L3
3/ L2
1/ L1
3
Q1
+
33
Q1
34
AC remote control
+
33
Q1
34
13
13
KM1
I
KM1
I
14
5/ L3
6/ T3
O
14
6/ T3
3/ L2
4/ T2
O
13
2/ T1
4/ T2
1/ L1
2/ T1
A1
I> I> I>
A1+
A1+
KM1
1-phase
M
43
Q1
44
DC local control
A2-
A2-
KM1
-
43
Q1
44
1SBC101272S0201
14
A2
KM1
DC remote control
ABB | 4/9
DOL starters protected by MS116 manual motor starters
With AS contactors - open type version in kit form
Coordination type 1 or type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
IEC
Type
AC-3, 400 V
Rated operational
power current
kW
A
Coordination type 1
Order code
I>
Current
setting
range
Magnetic Rated control circuit
tripping voltage
current Uc
A
A
Type
Order code
Allowed
setting
current
(1)
V 50 Hz
V 60 Hz
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
A
Coordination type 2
0.06
0.2
MS116-0.25
1SAM250000R1002
0.16...0.25 2.44
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS12-30-10-20
AS12-30-10-16
AS12-30-10-26
AS12-30-10-28
AS12-30-10-20
AS12-30-10-16
AS12-30-10-26
AS12-30-10-28
AS12-30-10-20
AS12-30-10-16
AS12-30-10-26
AS12-30-10-28
AS16-30-10-20
AS16-30-10-16
AS16-30-10-26
AS16-30-10-28
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL111001R2010
1SBL111001R1610
1SBL111001R2610
1SBL111001R2810
1SBL111001R2010
1SBL111001R1610
1SBL111001R2610
1SBL111001R2810
1SBL111001R2010
1SBL111001R1610
1SBL111001R2610
1SBL111001R2810
1SBL121001R2010
1SBL121001R1610
1SBL121001R2610
1SBL121001R2810
0.09
0.3
MS116-0.4
1SAM250000R1003
0.25...0.40 3.9
0.12
0.44
MS116-0.63
1SAM250000R1004
0.40...0.63 6.14
0.18
0.6
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.25
0.85
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.37
1.1
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.55
1.5
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.75
1.9
MS116-2.5
1SAM250000R1007
1.60...2.50 28.75
1.1
2.7
MS116-4.0
1SAM250000R1008
2.50...4.00 50
1.5
3.6
MS116-4.0
1SAM250000R1008
2.50...4.00 50
2.2
4.9
MS116-6.3
1SAM250000R1009
4.00...6.30 78.75
3
6.5
MS116-10
1SAM250000R1010
6.30...10.0 150
4
8.5
MS116-10
1SAM250000R1010
6.30...10.0 150
5.5
11.5
MS116-12
1SAM250000R1012
8.00...12.0 180
7.5
15.5
MS116-16
1SAM250000R1011
10.0...16.0 240
Main accessories
Type
Order code
Connecting link for manual motor starter
BEA16-3
1SBN081006T1000
Note: for multiple packaging, please contact your ABB local sales organization.
4/10 | ABB
(1) Other control voltages see voltage code table.
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
12
15.5
1SBC101383S0201
4
Iq = 16 kA
Iq = 50 kA
DOL starters protected by MS116 manual motor starters
With ASL contactors - open type version in kit form
Coordination type 1 or type 2, AC-3, 16 or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
IEC
Type
AC-3, 400 V
Rated operational
power current
kW
A
Coordination type 1
Order code
I>
Current
setting
range
Magnetic Rated control circuit Type
tripping voltage
current Uc
A
A
Order code
Allowed
setting
current
(1)
V DC
A
Coordination type 2
Iq = 16 kA
Iq = 50 kA
0.2
MS116-0.25
1SAM250000R1002
0.16...0.25 2.44
0.09
0.3
MS116-0.4
1SAM250000R1003
0.25...0.40 3.9
0.12
0.44
MS116-0.63
1SAM250000R1004
0.40...0.63 6.14
0.18
0.6
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.25
0.85
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.37
1.1
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.55
1.5
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.75
1.9
MS116-2.5
1SAM250000R1007
1.60...2.50 28.75
1.1
2.7
MS116-4.0
1SAM250000R1008
2.50...4.00 50
1.5
3.6
MS116-4.0
1SAM250000R1008
2.50...4.00 50
2.2
4.9
MS116-6.3
1SAM250000R1009
4.00...6.30 78.75
3
6.5
MS116-10
1SAM250000R1010
6.30...10.0 150
4
8.5
MS116-10
1SAM250000R1010
6.30...10.0 150
5.5
11.5
MS116-12
1SAM250000R1012
8.00...12.0 180
7.5
15.5
MS116-16
1SAM250000R1011
10.0...16.0 240
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL12-30-10-81
ASL12-30-10-83
ASL12-30-10-86
ASL12-30-10-88
ASL12-30-10-81
ASL12-30-10-83
ASL12-30-10-86
ASL12-30-10-88
ASL12-30-10-81
ASL12-30-10-83
ASL12-30-10-86
ASL12-30-10-88
ASL16-30-10-81
ASL16-30-10-83
ASL16-30-10-86
ASL16-30-10-88
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL113001R8110
1SBL113001R8310
1SBL113001R8610
1SBL113001R8810
1SBL113001R8110
1SBL113001R8310
1SBL113001R8610
1SBL113001R8810
1SBL113001R8110
1SBL113001R8310
1SBL113001R8610
1SBL113001R8810
1SBL123001R8110
1SBL123001R8310
1SBL123001R8610
1SBL123001R8810
Main accessories
Type
Order code
Connecting link for manual motor starter
BEA16-3
1SBN081006T1000
Note: for multiple packaging, please contact your ABB local sales organization.
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
4
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
12
15.5
1SBC101383S0201
0.06
(1) Other control voltages see voltage code table.
ABB | 4/11
Reversing starters protected by manual motor starters
With AS, ASL contactors - open type version in kit form
Application
I>
Full voltage reversing starting for controlling three-phase asynchronous motors is a simple and economic
solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting current
5.5 to 7 times nominal current.
I/In C/Cn
7
6
1SBC101027F0014
I
4
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
2
MS116 + BEA16-3 + VM3 +
BER16C-3 + AS16-30-01
C
1
0
10
30
60
80
100
Coordination types
The contactor and the manual motor starter control and protect motors against overload and short-circuits
according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of
service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts light welding is acceptable.
Main technical data
Standards
IEC 60947-4-1 / EN 60947-4-1
Rated operational voltage Ue max.
690 V - 50/60 Hz
Rated insulation voltage Ui according to IEC 60947-4-1 690 V
Switching frequency
≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time
≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting time
Ambient air temperature close to the device
≤ 55 °C
Degree of protection
IP20
Note: Minimum switchover delay of 50 ms must be introduced between respective opening and closing of AC operated reversing
contactors
Mounting positions
Pos
os. 2
-30°
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
4/12 | ABB
1SBC101274S0201
Pos. 4
+30°
Reversing starters protected by manual motor starters
With AS, ASL contactors - open type version in kit form
Description
You can easily assemble reversing starter thanks to our complete range of
accessories:
– – BEA16-3 connecting link 3-pole insulated: it is used to electrically and
mechanically connect MS116 manual motor starter and AS or ASL contactors.
– – VM3 mechanical interlock unit: just clip it between the 2 contactors without
increasing starter width.
– – BER16C-3 connection set: it assures a safe and simple connection between
both contactor main terminals and an electrical interlocking between coil and
N.C. built-in auxiliary contact terminals of both contactors.
I>
MS116
Manual motor starter
BEA16-3
Connecting link
4
Select now easily and quickly your starter in the following pages for coordination
type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA or Iq = 50 kA up to 7.5 kW.
For complete coordination tables with MS116 or MS132, please contact your ABB
local sales organization.
AS
ASL
Contactors
VM3
Mechanical
interlock unit
BER16C-3
Connection set
Wiring diagrams
43
44
5/L3
33
34
3/L2
1/L1
KM2:5/L3
Us
33
KM2:5/L3
Q1
34
Us
Q1
33
34
Q1
O
O
14
44
21
A1
Q1
KM2:3/L2
22
22
43
21
Us
N
A1
21
A1
A2
KM2
KM1
KM1
KM2
A2
14
22
21
A1
KM1
KM2
A2
44
KM2
I
KM1
A2
Q1
KM2
14
13
M
43
KM1
13
13
22
13
14
6/T3
4/T2
2/T1
KM2
Us
N
U1 V1 W1
II
14
5/L3
21
22
3/L2
1/L1
A1
14
6/T3
4/T2
2/T1
KM2
A2
13
21
22
5/L3
3/L2
1/L1
A1
A2
KM2:3/L2
AC local control
AC remote control
3
Power circuit
+
33
Q1
34
+
33
Q1
34
O
O
43
43
13
22
21
A1+
KM2
A2-
A2-
-
Q1
A2-
21
A1+
DC local control
14
14
KM1
KM2
44
KM1
21
KM2
44
DC remote control
ABB | 4/13
1SBC101274S0201
-
22
14
21
KM1
KM2
I
KM1
A1+
KM2
Q1
KM1
KM2
A1+
22
14
II
22
KM1
I
13
13
13
II
A2-
KM1
KM1
I
13
II
6/T3
4/T2
2/T1
I> I> I>
Reversing starters protected by MS116 manual motor starters
With AS contactors - open type version in kit form
Coordination type 1 or type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
IEC
Type
AC-3, 400 V
Rated operational
power current
kW
A
Coordination type 1
Coordination type 2
Order code
I>
Current
setting
range
Magnetic Rated control circuit
tripping voltage
current Uc
A
A
Type
Order code
Allowed
setting
current
(1)
V 50 Hz
V 60 Hz
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
A
Iq = 16 kA
Iq = 50 kA
0.06
0.2
MS116-0.25
1SAM250000R1002
0.16...0.25 2.44
0.09
0.3
MS116-0.4
1SAM250000R1003
0.25...0.40 3.9
0.12
0.44
MS116-0.63
1SAM250000R1004
0.40...0.63 6.14
0.18
0.6
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.25
0.85
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.37
1.1
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.55
1.5
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.75
1.9
MS116-2.5
1SAM250000R1007
1.60...2.50 28.75
1.1
2.7
MS116-4.0
1SAM250000R1008
2.50...4.00 50
1.5
3.6
MS116-4.0
1SAM250000R1008
2.50...4.00 50
2.2
4.9
MS116-6.3
1SAM250000R1009
4.00...6.30 78.75
3
6.5
MS116-10
1SAM250000R1010
6.30...10.0 150
4
8.5
MS116-10
1SAM250000R1010
6.30...10.0 150
5.5
11.5
MS116-12
1SAM250000R1012
8.00...12.0 180
7.5
15.5
MS116-16
1SAM250000R1011
10.0...16.0 240
Note: for multiple packaging, please contact your ABB local sales organization.
upstream
connection
BEA16-3
4/14 | ABB
BER16C-3
downstream
connection
VM3
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS12-30-01-20
AS12-30-01-16
AS12-30-01-26
AS12-30-01-28
AS12-30-01-20
AS12-30-01-16
AS12-30-01-26
AS12-30-01-28
AS12-30-01-20
AS12-30-01-16
AS12-30-01-26
AS12-30-01-28
AS16-30-01-20
AS16-30-01-16
AS16-30-01-26
AS16-30-01-28
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL111001R2001
1SBL111001R1601
1SBL111001R2601
1SBL111001R2801
1SBL111001R2001
1SBL111001R1601
1SBL111001R2601
1SBL111001R2801
1SBL111001R2001
1SBL111001R1601
1SBL111001R2601
1SBL111001R2801
1SBL121001R2001
1SBL121001R1601
1SBL121001R2601
1SBL121001R2801
Type
BEA16-3
BER16C-3
VM3
Order code
1SBN081006T1000
1SBN081012R1000
1SBN031005T1000
(1) Other control voltages see voltage code table.
Main accessories
Connecting link for manual motor starter
Connection set for reversing starter
Mechanical interlock unit
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
12
15.5
1SBC101273S0201
4
Reversing starters protected by MS116 manual motor starters
With ASL contactors - open type version in kit form
Coordination type 1 or type 2, AC-3, 16 or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
IEC
Type
AC-3, 400 V
Rated operational
power current
kW
A
Coordination type 1
Coordination type 2
Order code
I>
Current
setting
range
Magnetic Rated control circuit Type
tripping voltage
current Uc
A
A
Order code
Allowed
setting
current
(1)
V DC
A
Iq = 16 kA
Iq = 50 kA
0.2
MS116-0.25
1SAM250000R1002
0.16...0.25 2.44
0.09
0.3
MS116-0.4
1SAM250000R1003
0.25...0.40 3.9
0.12
0.44
MS116-0.63
1SAM250000R1004
0.40...0.63 6.14
0.18
0.6
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.25
0.85
MS116-1.0
1SAM250000R1005
0.63...1.00 11.5
0.37
1.1
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.55
1.5
MS116-1.6
1SAM250000R1006
1.00...1.60 18.4
0.75
1.9
MS116-2.5
1SAM250000R1007
1.60...2.50 28.75
1.1
2.7
MS116-4.0
1SAM250000R1008
2.50...4.00 50
1.5
3.6
MS116-4.0
1SAM250000R1008
2.50...4.00 50
2.2
4.9
MS116-6.3
1SAM250000R1009
4.00...6.30 78.75
3
6.5
MS116-10
1SAM250000R1010
6.30...10.0 150
4
8.5
MS116-10
1SAM250000R1010
6.30...10.0 150
5.5
11.5
MS116-12
1SAM250000R1012
8.00...12.0 180
7.5
15.5
MS116-16
1SAM250000R1011
10.0...16.0 240
Note: for multiple packaging, please contact your ABB local sales organization.
upstream
connection
BEA16-3
BER16C-3
downstream
connection
VM3
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL12-30-01-81
ASL12-30-01-83
ASL12-30-01-86
ASL12-30-01-88
ASL12-30-01-81
ASL12-30-01-83
ASL12-30-01-86
ASL12-30-01-88
ASL12-30-01-81
ASL12-30-01-83
ASL12-30-01-86
ASL12-30-01-88
ASL16-30-01-81
ASL16-30-01-83
ASL16-30-01-86
ASL16-30-01-88
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL113001R8101
1SBL113001R8301
1SBL113001R8601
1SBL113001R8801
1SBL113001R8101
1SBL113001R8301
1SBL113001R8601
1SBL113001R8801
1SBL113001R8101
1SBL113001R8301
1SBL113001R8601
1SBL113001R8801
1SBL123001R8101
1SBL123001R8301
1SBL123001R8601
1SBL123001R8801
Type
BEA16-3
BER16C-3
VM3
Order code
1SBN081006T1000
1SBN081012R1000
1SBN031005T1000
0.25
0.4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
10
12
15.5
(1) Other control voltages see voltage code table.
Main accessories
Connecting link for manual motor starter
Connection set for reversing starter
Mechanical interlock unit
4
1SBC101273S0201
0.06
ABB | 4/15
DOL starters protected by MS116 manual motor starters
With AS, ASL contactors - open type version in kit form
17.5
0.69"
176 6.93"
176 6.93"
26.25
1.03"
ø 4.5 0.18"
10 0.39"
ø 4.5 0.18"
10 0.39"
17.5
0.69"
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
10.1 0.4"
6 0.24"
85.6 3.37"
75 2.95"
170 6.69"
4
6 0.24"
Main dimensions mm, inches
Direct-on-line starters
26.25
1.03"
72.5 2.85"
10 0.39"
35 1.38"
5 0.2"
ø 4.2
0.17"
5 0.2"
35 1.38"
5 0.2"
4 0.16"
7 0.28"
45 1.77"
4 0.16"
ø 4.2
0.17"
5 0.2"
5 0.2"
1SBC101279S0201
MS116
+ BEA16-3
+ AS09, ASL09, AS12, ASL12, AS16, ASL16
4/16 | ABB
Reversing starters protected by MS116 manual motor starters
With AS, ASL contactors - open type version in kit form
ø 4.2
0.17"
ø 4.5 0.18"
80 3.15"
10 0.39"
5
0.20"
26.25
1.03"
4
5 0.2"
4 0.16"
4 0.16"
10 0.39"
6 0.24"
176 6.93"
26.25
1.03"
5 0.2"
72.5 2.85"
17.5
0.69"
10 0.39"
176 6.93"
35 mm EN/IEC 60715
5.5
0.22"
3 0.12"
170 6.69"
ø 4.5 0.18"
10.1 0.40"
7 0.28"
90 3.54"
17.5
0.69"
5 0.2"
75 2.95"
85.6 3.37"
45 1.77"
45 1.77"
6 0.24"
Main dimensions mm, inches
Reversing starters
ø 4.2
0.17"
80 3.15"
5
0.20"
1SBC101278S0201
MS116
+ BEA16-3 + BER16C-3 + VM3
+ AS09, ASL09, AS12, ASL12, AS16, ASL16
ABB | 4/17
DOL & reversing starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Application
1SBC101204F0014
Full voltage direct-on-line and reversing starting for controlling three-phase asynchronous motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and
a starting current 5.5 to 7 times nominal current.
I/In C/Cn
7
6
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
2
C
1
0
1SBC101205F0014
10
30
60
80
100
Coordination types
The contactor, the short-circuit protection device and the thermal overload relay control and protect
motors against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 /
EN 60947-4-1) defining the anticipated level of service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts light welding is acceptable.
AS09-30-01 + BER16C + VM3 + T16
Main technical data
Standards
IEC 60947-4-1 / EN 60947-4-1
Rated operational voltage Ue max.
690 V - 50/60 Hz
Rated insulation voltage Ui according to IEC 60947-4-1
690 V
Air temperature close to the device
≤ 60 °C
Degree of protection
IP20
Switching frequency
Thermal overload relays cannot be operated at any
arbitrary switching frequency in order to avoid tripping.
Applications involving up to 15 operations per hour are
acceptable. Higher switching frequencies are permitted
if the duty ratio and the motor starting time are allowed
for and if the motor's making current does not appreciably exceed 6 times the rated operating current. Please
refer to the adjacent diagram for guideline values for
the permitted switching frequency.
Example:
Starting time of the motor: 1 second Duty ratio: 40 %
means a permitted switching frequency of max. 60
operating cycles per hour.
Switching frequency (ops/h)
140
Ta
=
120
0.
5
s
100
Ta =
80
1s
60
Ta =
1.5 s
40
Ta = 3 s
20
Ta = 5 s
0
0
10
20
30
40
50
60
70
80
90
100
Duty ratio (%)
Duty ratio in %, Ta: motor starting time
Note: Minimum switchover delay of 50 ms must be introduced between respective opening and closing of AC operated reversing
contactors
Mounting positions
Direct-on-line
Pos. 1
4/18 | ABB
Reversing
Pos. 1
1SBC101275S0201
4
AS09-30-10 + T16
DOL & reversing starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Direct-on-line starters
Reversing starters
Description
You can easily assemble a direct-on-line starter by
connecting AS or ASL contactors and T16 thermal
overload relay.
You can easily assemble reversing starter thanks to our
complete range of accessories:
– – VM3 mechanical interlock unit: just clip it between the
2 contactors without increasing starter length.
– – BER16C-3 connection set: it assures a safe and simple
reversing connection between both contactor main
terminals and an electrical interlocking between coil
and N.C. built-in auxiliary contact terminals of both
contactors.
BER16C-3
Connection
set
AS
ASL
Contactors
VM3
Mechanical
interlock
unit
AS
ASL
Contactors
4
Select now easily and quickly your starter in the following pages at 400 V, up to 7.5 kW.
T16
Thermal overload relay
For complete coordination tables, please contact your
ABB local sales organization.
T16
Thermal overload relay
Wiring diagrams
96
FR1
2/T1
4/T2
6/T3
14
STOP
FR1
STOP
FR1
FR1
KM1
I
KM1
14
14
I
14
KM1
I
13
13
13
KM1
U
Power circuit
W
U
M
~
A1+
KM1
A2-
A2-
A2
KM1
-
KM1:3/L2
-
V
M
~
1-phase
KM1
Us
N
KM1:3/L2
V
A1+
A1
KM1
Us
N
A2
2/T1
4/T2
6/T3
A1
FR1
2/T1
4/T2
6/T3
96
98
FR1
TEST
STOP
A
M
95
97
A
M
RESET
O
14
I
RESET
M
O
13
2/T1
4/T2
6/T3
14
A2
STOP
96
STOP
KM1
RESET
M
95
RESET
+
A
96
M
95
RESET
+
A
95
Us
A
96
KM1:5/L3
Us
95
1/L1
3/L2
5/L3
KM1:5/L3
13
A1
13
1/L1
3/L2
5/L3
Direct-on-line starters
AC local control
AC remote control
DC local control
DC remote control
STOP
FR1
96
96
FR1
AC remote control
13
22
KM1
KM2
A2-
-
KM1
A1+ 21
A1+ 21
A1+ 21
A2-
A2-
14
13
22
14
22
22
KM2
KM2
DC local control
KM2
I
KM1
KM1
-
14
KM2
14
II
A1+ 21
KM2
KM1:3/L2
KM1
13
13
14
21
A1
KM2
A2
A2
KM1
22
21
KM1
A2
21
A1
Us
N
KM1
A1
KM2
KM2
AC local control
13
13
22
14
21
A1
KM1
KM1:3/L2
I
DC remote control
ABB | 4/19
1SBC101275S0201
W
22
22
V
M
~
Us
N
A2
2/T1
4/T2
6/T3
U
II
KM2
I
KM1
FR1
STOP
STOP
14
KM2
A
M
O
KM1
13
13
II
14
KM1
RESET
95
95
FR1
+
A
M
II
95
97
FR1
Power circuit
RESET
O
KM2
96
98
TEST
STOP
+
A
M
96
STOP
I
A
RESET M
RESET
Us
A2-
21
13
2/T1
4/T2
6/T3
22
14
1/L1
3/L2
5/L3
A1
A2
21
13
1/L1
3/L2
5/L3
A1
A2
2/T1
4/T2
6/T3
22
14
KM1
KM2
KM1:5/L3
A
M
95
RESET
Us
96
KM1:5/L3
95
Reversing starters
DOL starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Contactors - AC operated
Contactors
5.5
11.5
7.5
15.5
Rated control
circuit voltage
Uc
Type
Order code
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS12-30-10-20
AS12-30-10-16
AS12-30-10-26
AS12-30-10-28
AS16-30-10-20
AS16-30-10-16
AS16-30-10-26
AS16-30-10-28
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL111001R2010
1SBL111001R1610
1SBL111001R2610
1SBL111001R2810
1SBL121001R2010
1SBL121001R1610
1SBL121001R2610
1SBL121001R2810
Setting
ranges
Accessories
Type
Order code
A ... A
7.60...10.0
T16-10
1SAZ711201R1043
-
10.0...13.0
T16-13
1SAZ711201R1045
-
13.0...16.0
T16-16
1SAZ711201R1047
-
Setting
ranges
Type
Order code
A ... A
7.60...10.0
T16-10
1SAZ711201R1043
-
10.0...13.0
T16-13
1SAZ711201R1045
-
13.0...16.0
T16-16
1SAZ711201R1047
-
(1)
V 50 Hz
24
230
400
24
230
400
24
230
400
V 60 Hz
24
120
230
400
24
120
230
400
24
120
230
400
Contactors - DC operated
IEC
AC-3, 400 V
Rated operational
power current
kW
A
4
8.5
5.5
11.5
7.5
15.5
Rated control
circuit voltage
Uc
Type
Order code
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL12-30-10-81
ASL12-30-10-83
ASL12-30-10-86
ASL12-30-10-88
ASL16-30-10-81
ASL16-30-10-83
ASL16-30-10-86
ASL16-30-10-88
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL113001R8110
1SBL113001R8310
1SBL113001R8610
1SBL113001R8810
1SBL123001R8110
1SBL123001R8310
1SBL123001R8610
1SBL123001R8810
(1)
DC
24
48
110
220
24
48
110
220
24
48
110
220
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
see table below for all setting ranges
Setting
ranges
A ... A
0.10...0.13
0.13...0.17
0.17...0.23
0.23...0.31
0.31...0.41
0.41...0.55
0.55...0.74
0.74...1.00
1.00...1.30
1.30...1.70
1.70...2.30
2.30...3.10
3.10...4.20
4.20...5.70
5.70...7.60
7.60...10.0
10.0...13.0
13.0...16.0
4/20 | ABB
Type
Order code
T16-0.13
T16-0.17
T16-0.23
T16-0.31
T16-0.41
T16-0.55
T16-0.74
T16-1.0
T16-1.3
T16-1.7
T16-2.3
T16-3.1
T16-4.2
T16-5.7
T16-7.6
T16-10
T16-13
T16-16
1SAZ711201R1005
1SAZ711201R1008
1SAZ711201R1009
1SAZ711201R1013
1SAZ711201R1014
1SAZ711201R1017
1SAZ711201R1021
1SAZ711201R1023
1SAZ711201R1025
1SAZ711201R1028
1SAZ711201R1031
1SAZ711201R1033
1SAZ711201R1035
1SAZ711201R1038
1SAZ711201R1040
1SAZ711201R1043
1SAZ711201R1045
1SAZ711201R1047
1SBC101280S0201
4
IEC
AC-3, 400 V
Rated operational
power current
kW
A
4
8.5
Thermal overload relays
Reversing starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Contactors - AC operated
Contactors
Thermal overload relays
Accessories
VM3
+
BER16C-3
IEC
AC-3, 400 V
Rated operational
power current
kW
A
4
8.5
5.5
11.5
7.5
15.5
Rated control
circuit voltage
Uc
Type
Order code
Setting
ranges
Type
Order code
Type
CA3-10
Order code
(1)
V 50 Hz
24
230
400
24
230
400
24
230
400
V 60 Hz
24
120
230
400
24
120
230
400
24
120
230
400
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS12-30-01-20
AS12-30-01-16
AS12-30-01-26
AS12-30-01-28
AS16-30-01-20
AS16-30-01-16
AS16-30-01-26
AS16-30-01-28
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL111001R2001
1SBL111001R1601
1SBL111001R2601
1SBL111001R2801
1SBL121001R2001
1SBL121001R1601
1SBL121001R2601
1SBL121001R2801
4
A ... A
7.60...10.0
T16-10
1SAZ711201R1043
10.0...13.0
T16-13
1SAZ711201R1045
13.0...16.0
T16-16
1SAZ711201R1047
Setting
ranges
Type
A ... A
7.60...10.0
BER16C-3
+
VM3
+
2x CA3-10
BER16C-3
+
VM3
+
2x CA3-10
BER16C-3
+
VM3
+
2x CA3-10
1SBN081012R1000
+
1SBN031005T1000
+
1SBN011010T1010
1SBN081012R1000
+
1SBN031005T1000
+
1SBN011010T1010
1SBN081012R1000
+
1SBN031005T1000
+
1SBN011010T1010
Order code
Type
Order code
T16-10
1SAZ711201R1043
10.0...13.0
T16-13
1SAZ711201R1045
13.0...16.0
T16-16
1SAZ711201R1047
BER16C-3
+
VM3
+
2x CA3-10
BER16C-3
+
VM3
+
2x CA3-10
BER16C-3
+
VM3
+
2x CA3-10
1SBN081012R1000
+
1SBN031005T1000
+
1SBN011010T1010
1SBN081012R1000
+
1SBN031005T1000
+
1SBN011010T1010
1SBN081012R1000
+
1SBN031005T1000
+
1SBN011010T1010
Contactors - DC operated
5.5
11.5
7.5
15.5
Rated control
circuit voltage
Uc
Type
Order code
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL12-30-10-81
ASL12-30-10-83
ASL12-30-10-86
ASL12-30-10-88
ASL16-30-10-81
ASL16-30-10-83
ASL16-30-10-86
ASL16-30-10-88
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL113001R8110
1SBL113001R8310
1SBL113001R8610
1SBL113001R8810
1SBL123001R8110
1SBL123001R8310
1SBL123001R8610
1SBL123001R8810
(1)
DC
24
48
110
220
24
48
110
220
24
48
110
220
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
see table below for all setting ranges
Setting
ranges
A ... A
0.10...0.13
0.13...0.17
0.17...0.23
0.23...0.31
0.31...0.41
0.41...0.55
0.55...0.74
0.74...1.00
1.00...1.30
1.30...1.70
1.70...2.30
2.30...3.10
3.10...4.20
4.20...5.70
5.70...7.60
7.60...10.0
10.0...13.0
13.0...16.0
Type
Order code
T16-0.13
T16-0.17
T16-0.23
T16-0.31
T16-0.41
T16-0.55
T16-0.74
T16-1.0
T16-1.3
T16-1.7
T16-2.3
T16-3.1
T16-4.2
T16-5.7
T16-7.6
T16-10
T16-13
T16-16
1SAZ711201R1005
1SAZ711201R1008
1SAZ711201R1009
1SAZ711201R1013
1SAZ711201R1014
1SAZ711201R1017
1SAZ711201R1021
1SAZ711201R1023
1SAZ711201R1025
1SAZ711201R1028
1SAZ711201R1031
1SAZ711201R1033
1SAZ711201R1035
1SAZ711201R1038
1SAZ711201R1040
1SAZ711201R1043
1SAZ711201R1045
1SAZ711201R1047
1SBC101280S0201
IEC
AC-3, 400 V
Rated operational
power current
kW
A
4
8.5
ABB | 4/21
Star-delta starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Application
L Δ
Y
Star-delta starting is the most common method to reduce the starting current of a motor.
This system can be used on all the squirrel cage motors, which are normally used in delta connection. In
this type of starting, it is recommended to choose motors having high starting torque i.e. much higher than
the resistive torque in order to reach sufficient high speed when the motor is connected in star.
I/In T/T
n
7
1SBC101207F0014
When starting:
4
AS09-30-10 + AS09-30-01
+ AS09-30-01 + BEY16C-3 + VM3
+ CT-SDS + CA3-10 + T16
– – Inrush current is reduced to a third of direct starting
current
– – Motor torque is reduced to a third or even less of direct
starting torque.
Transient current is generated when switching from star to
delta connection.
During the initial starting phase ("star" connection), the
resistive torque of the driven load must remain, irrespective
of speed, less than the "star" motor torque until "star-delta"
switching occurs.
This starting mode is therefore ideal for machines having
low starting torque such as pumps, centrifugal compressors, wood-working machines...
I = current
T = torque
6
In = nominal current
Tn = nominal torque
I (delta)
5
4
3
T∆ (motor)
I (star)
2
1
T (motor)
Tr (resistive torque)
0
20
40
60
80
100
Motor speed (%)
Precaution
– – Motor nominal voltage in delta connection must be equal to that of the mains. Example: a motor for
400 V star-delta starting must be designed for 400 V in "delta" connection. Its usual designation is
"400 V / 690 V motor". The motor must be constructed with 6 terminal windings
– – In order to prevent a high current peak, at least 85 % of nominal speed must be reached before switching from star to delta
Sequence
Starting is a three-stage process:
1 st stage: "Star" connection - Press the "On" button on the control circuit to close the KM2 "Star" contactor. The KM1 "line" contactor then closes and the motor starts. Countdown of programmed starting time
(6 to 10 s) then begins.
2 nd stage: "Star" to "Delta" switching - when programmed starting time is over, the KM2 "Star" contactor
opens.
3 rd stage: "Delta" connection - A transition time (or dwelling time) of 50 ms is fixed between opening of the
"star" contactor and closing of the "delta" contactor by the use of CT-SDS timer. This prevent short-circuit
between "star" and "delta".
Main technical data
IEC 60947-4-1 / EN 60947-4-1
690 V - 50/60 Hz
690 V
≤ 60 °C
IP20
70
60
ta =
5s
50
40
ta =
ta =
30
8s
10 s
ta = 1
2s
20
ta = 15
s
ta = 20 s
10
0
0
10
20
30
40
50
Pos. 1
70
80
90
100
Duty ratio (%)
Duty ratio in %, Ta: acceleration time
4/22 | ABB
60
1SBC101288S0201
Switching frequency (ops/h)
Mounting positions
Standards
Rated operational voltage Ue max.
Rated insulation voltage Ui according to IEC 60947-4-1
Air temperature close to the device
Degree of protection
Switching frequency
Switching frequency/hour, according to acceleration
time and load factor. Respect of the following conditions enables utilization of the starter without excessive
overheating of the connections or nuisance tripping of
the thermal overload relay.
Example:
– Switching frequency = 15 starts/hr
– Motor starting time "Ta" = 7 s (use 8 s curve)
– Maximum load factor = 63 %.
This corresponds to a 4-minute operating cycle (15
starts/hr) with 7 seconds acceleration, 2.5 minutes
operation and 1.5 minutes rest.
Star-delta starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
L Δ
Y
Description
Timer
BEY16C-3
Connection set
You can easily assemble a star-delta starter thanks to our
complete range of accessories:
– – VM3 mechanical interlock unit: just clip it between the
2 contactors without increasing starter length.
– – BEY16C-3 connection set: it assures a safe and simple
connection between contactors main terminals and an
electrical interlocking between coil and N.C. built-in
auxiliary contact terminals of star and delta contactors.
2
KM
3
1
KM
KM
VM3
Mechanical
interlock unit
Select now easily and quickly your starter in the following pages at 400 V, up to 11 kW.
CA3
1-pole auxiliary
contact block
AS
ASL
Contactors
4
For complete coordination tables, please contact your
ABB local sales organization.
BEY16C-3
Connection set
T16
Thermal overload relay
Wiring diagrams
W2
V2
U2
23
24
17
17
A1
22 18
A1 21
A2
A2
22 28
A1 21
A2
KM2 KT
Y
14
AC remote control
FR1
RESET MA
O
STOP
FR1
I
23
23
STOP
A1 14
L
+
RESET A
M
KM3
A2
A1
A2
A1 21
A2
KM1
AC local control
+
13
13
22 18
22 28
A2
Y
KM3
95
W1
V1
U1
KM1:3/L2
KM2 KT
KM3
L
KM2
96
W2
V2
U2
Us
N
95
W1
V1
U1
A1 21
14
KM1
KM1:3/L2
KM2 KM1
KM3
KM2
96
2/T1
4/T2
6/T3
KM2 KM1
Us
N
I
KM1
A2
13
13
96
98
FR1
FR1
KT
A1 14
95
97
TEST
STOP
O
95
STOP
KM1
I
KT
RESET A
M
96
95
FR1
24
A2
A
RESET M
Us
2/T1
4/T2
6/T3
14
22
A2
2/T1
4/T2
6/T3
22
96
1/L1
3/L2
5/L3
13
21
A1
1/L1
3/L2
5/L3
21
A1
1/L1
3/L2
5/L3
13
23
A1
A2
STOP
KM2
KM3
2/T1
4/T2
6/T3
14
24
KM1
KM1:5/L3
A
RESETM
Us
23
KM1:5/L3
KM1
KM1
KT
DC local control
22 18
L
A1+ 21
A2-
A1+
A1+ 21
KM3
KT
A2-
KM2
KM3
A2-
A2-
KM1
-
22 28
13
13
14
A1+ 14
A1+
22 28
22 18
21
Y
KM2
Y
DC remote control
ABB | 4/23
1SBC101288S0201
L
KM2 KM1
KM2 KT
KM3
KM1
-
A1+
t2
A2-
t1
t1 = adjusted starting time
t2 = transition time (50ms)
A2-
green LED
KM3
A1+
21
KM2
A1+
17-28
KT
A2-
KM1
14
KM2
13
13
17-18
14
A1-A2
A2-
Function diagram Electronic Timer
17
17
24
24
I
Star-delta starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Contactors - AC operated
L Δ
Star contactor KM2
Type
Order code
Type
Order code
Type
Order code
AS09-30-10-20
AS09-30-10-16
AS09-30-10-26
AS09-30-10-28
AS12-30-10-20
AS12-30-10-16
AS12-30-10-26
AS12-30-10-28
1SBL101001R2010
1SBL101001R1610
1SBL101001R2610
1SBL101001R2810
1SBL111001R2010
1SBL111001R1610
1SBL111001R2610
1SBL111001R2810
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS12-30-01-20
AS12-30-01-16
AS12-30-01-26
AS12-30-01-28
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL111001R2001
1SBL111001R1601
1SBL111001R2601
1SBL111001R2801
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
AS09-30-01-20
AS09-30-01-16
AS09-30-01-26
AS09-30-01-28
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
1SBL101001R2001
1SBL101001R1601
1SBL101001R2601
1SBL101001R2801
Type
Order code
Type
Order code
Type
Order code
ASL09-30-10-81
ASL09-30-10-83
ASL09-30-10-86
ASL09-30-10-88
ASL12-30-10-81
ASL12-30-10-83
ASL12-30-10-86
ASL12-30-10-88
1SBL103001R8110
1SBL103001R8310
1SBL103001R8610
1SBL103001R8810
1SBL113001R8110
1SBL113001R8310
1SBL113001R8610
1SBL113001R8810
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL12-30-01-81
ASL12-30-01-83
ASL12-30-01-86
ASL12-30-01-88
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL113001R8101
1SBL113001R8301
1SBL113001R8601
1SBL113001R8801
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
ASL09-30-01-81
ASL09-30-01-83
ASL09-30-01-86
ASL09-30-01-88
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
1SBL103001R8101
1SBL103001R8301
1SBL103001R8601
1SBL103001R8801
Y
IEC
AC-3, 400 V
Rated operational
power current
kW
A
7.5
15.5
11
Delta contactor KM3
22
Rated control
circuit voltage
Uc
(1)
V 50 Hz
24
230
400
24
230
400
V 60 Hz
24
120
230
400
24
120
230
400
Contactors - DC operated
IEC
AC-3, 400 V
Rated operational
power current
kW
A
7.5
15.5
11
22
Rated control
circuit voltage
Uc
(1)
DC
24
48
110
220
24
48
110
220
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
1SBC101281S0201
4
Line contactor KM1
4/24 | ABB
Star-delta starters protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Thermal overload relays Connection sets
Mechanical interlock unit
Auxiliary contact block
Electronic timer
Type
Type
The setting current value is: nominal
motor current x 0.58
Setting
ranges
Type
Order code
Type
Order code
Order code
Order code
4
A ... A
7.60…10.0
10.0...13.0
Setting
ranges
A ... A
7.60...10.0
10.0...13.0
T16-10 1SAZ711201R1043
T16-13 1SAZ711201R1045
Type
Order code
T16-10 1SAZ711201R1043
T16-13 1SAZ711201R1045
BEY16C-3 1SBN081018R2000
+
+
VM3
1SBN031005T1000
KM1: 1 x CA3-10 1SBN011010T1010
BEY16C-3 1SBN081018R2000
+
+
VM3
1SBN031005T1000
KM1: 1 x CA3-10 1SBN011010T1010
Type
Type
Order code
KM2: 1 x CA3-10 1SBN011010T1010
KM2: 1 x CA3-10 1SBN011010T1010
Order code
CT-SDS… see "Ordering
Details"
CT-SDS… see "Ordering
Details"
Type
BEY16C-3 1SBN081018R2000
+
+
VM3
1SBN031005T1000
KM1: 1 x CA3-10 1SBN011010T1010
BEY16C-3 1SBN081018R2000
+
+
VM3
1SBN031005T1000
KM1: 1 x CA3-10 1SBN011010T1010
KM2: 1 x CA3-10 1SBN011010T1010
KM2: 1 x CA3-10 1SBN011010T1010
Order code
CT-SDS… see "Ordering
Details"
CT-SDS… see "Ordering
Details"
see table below for all setting ranges
Type
Order code
T16-0.13
T16-0.17
T16-0.23
T16-0.31
T16-0.41
T16-0.55
T16-0.74
T16-1.0
T16-1.3
T16-1.7
T16-2.3
T16-3.1
T16-4.2
T16-5.7
T16-7.6
T16-10
T16-13
T16-16
1SAZ711201R1005
1SAZ711201R1008
1SAZ711201R1009
1SAZ711201R1013
1SAZ711201R1014
1SAZ711201R1017
1SAZ711201R1021
1SAZ711201R1023
1SAZ711201R1025
1SAZ711201R1028
1SAZ711201R1031
1SAZ711201R1033
1SAZ711201R1035
1SAZ711201R1038
1SAZ711201R1040
1SAZ711201R1043
1SAZ711201R1045
1SAZ711201R1047
CT-SDS...
Ordering details - Main accessories
Type
Electronic timer*
28-48 V DC
24-240 V AC
380-440 V AC
Order code
Pkg
qty
Weight
CT-SDS.22S
1SVR730210R3300
1
(1 pce)
kg
0.114
CT-SDS.23S
1SVR730211R2300
1
0.118
* 7 time ranges (0.05 s - 10 min), 50 ms transition time, 2 n/o contacts, 3 LEDs
ABB | 4/25
1SBC101281S0201
Setting
ranges
A ... A
0.10...0.13
0.13...0.17
0.17...0.23
0.23...0.31
0.31...0.41
0.41...0.55
0.55...0.74
0.74...1.00
1.00...1.30
1.30...1.70
1.70...2.30
2.30...3.10
3.10...4.20
4.20...5.70
5.70...7.60
7.60...10.0
10.0...13.0
13.0...16.0
Protected by thermal overload relays
With AS, ASL contactors - open type version in kit form
Main dimensions mm, inches
Direct-on-line starters
72.5 2.85"
2x
M4 8-32 UNC
ø 4.2 0.17"
35 mm
EN/IEC 60715
5 0.2"
35 1.38"
5 0.2"
AC
17.3 0.68"
ø 4.2 0.17"
60 2.36"
60 2.36"
128.5 5.06"
68 2.68"
5.5 0.22"
35 1.38"
DC
5.3 0.21"
70.8 2.79"
Reversing starters
2x
M4 8-32 UNC
72.5 2.85"
10 0.39"
60 2.36"
7 0.28"
ø 4.2
0.17"
136.5 5.37"
68 2.68"
5.5 0.22"
AC
50 1.97"
67.3 2.65"
80 3.15"
17.3 0.68"
90 3.54"
DC
60 2.36"
35 mm
EN/IEC 60715
2x
M4 8-32 UNC
ø 4.2
5.3 0.21"
0.17"
70.8 2.79"
80 3.15"
Star-delta starters
103.7 4.08"
157.5 6.2"
2x
M4 8-32 UNC
72.5 2.85"
7 0.28"
50 1.97"
60 2.36"
5.5
68 2.68"
85.6 3.37"
AC
136.5 5.37"
ø 4.2
0.17"
0.22"
125 4.92"
2x
M4 8-32 UNC
22.5
DC
ø 4.2
5.3 0.21"
17.3 0.68"
0.17"
70.8 2.79"
125 4.92"
4/26 | ABB
1SBC101293S0201
0.89"
60 2.36"
5.9 0.23"
35 mm
EN/IEC 60715
4
2x
M4 8-32 UNC
10 0.39"
50 1.97"
7 0.28"
45 1.77"
Notes
N14
4
ABB | 4/27
Summary_4-2
4
4/28 | ABB
3-pole contactors and contactor relays
with screw terminals
3-pole contactors
Overview
4/30
AS09 ... AS16
AC operated
4/32
ASL09 ... ASL16
DC operated
4/33
AS09 ... AS16
AC operated - 2-stack
4/34
ASL09 ... ASL16
DC operated - 2-stack
4/35
Main accessories
4/36
Technical data
4/38
Electrical durability
4/44
Terminal marking and postioning
4/52
Dimensions
4/54
4
3-pole reversing contactors
VAS09 ... VAS16
AC operated
4/46
VASL09 ... VASL16
DC operated
4/47
Technical data
4/48
Terminal marking and postioning
4/52
Dimensions
4/58
Contactor relays
Overview
4/60
NS
AC operated
4/62
NSL
DC operated
4/63
Main accessories
4/64
Technical data
4/66
Terminal marking and positioning
4/70
Dimensions
4/72
Accessories
Auxiliary contact blocks
4/74
Electronic timers
4/77
Surge suppressors
4/80
4/82
Connection accessories for starting solutions
4/83
Voltage code table
4/84
Summary_4-2
Mechanical interlock unit and other accessories
ABB | 4/29
3-pole contactors
Main accessories
AS09 ... AS16
3-pole contactors
4
Main accessories for contactors
RV5, RT5 or RC5-1
Surge suppressor
CA-3
1-pole auxiliary contact block
T16
Thermal overload relay
Main accessories for starting solutions
Direct-on-line starter
Reversing starter
Star-delta starter
BEY16C-3
Connection set
BER16C-3
Connection set
Timer
AS
ASL
Contactors
AS
ASL
Contactors
AS
ASL
Contactors
VM3
Mechanical
interlock unit
T16
Thermal overload relay
T16
Thermal overload relay
4/30 | ABB
T16
Thermal overload relay
1SBC101292S0201
VM3
Mechanical
interlock unit
3-pole contactors
Screw terminals
AC control voltage
AS09
AS12
AS16
DC control voltage
ASL09
ASL12
ASL16
4
Switching of 3-phase cage motors
Rated operational power
33
M
3
Rated
operational
current
400 V
4 kW
5.5 kW
7.5 kW
θ ≤ 60 °C
400 V
9A
12 A
15.5 A
θ ≤ 60 °C
415 V
9A
12 A
15.5 A
5A
5 hp
7A
7.5 hp
9A
10 hp
00
00
0
IEC
AC-3
UL / CSA
690 V
θ ≤ 60 °C
440-480 V
3-phase motor rating
NEMA size
Protection of 3-phase motors
T16...
Thermal overload relays
0.10...0.13
0.23...0.31
0.55...0.74
1.30...1.70
3.10...4.20
7.60...10.0
0.13...0.17
0.31...0.41
0.74...1.00
1.70...2.30
4.20...5.70
10.0...13.0
0.17...0.23
0.41...0.55
1.00...1.30
2.30...3.10
5.70...7.60
13.0...16.0
Switching of resistive circuits
θ ≤ 40 °C
690 V
22 A
24 A
24 A
θ ≤ 60 °C
690 V
18 A
20 A
20 A
690 V
θ ≤ 70 °C
With conductor cross-sectional area
15 A
16 A
16 A
2.5 mm 2
20 A
2.5 mm 2
20 A
2.5 mm 2
20 A
With conductor cross-sectional area
AWG 12
AWG 12
AWG 12
Auxiliary
contact
blocks
Front mounting
1-pole CA3-10 or CA3-01
Interlocks
Mechanical
VM3
Surge
suppressors
Side-mounted
(without additional
width)
RV5
RC5-1
RT5
Connection
sets
Reversing starters
Star-delta starters
BER16C-3
BEY16C-3
Connecting
link
With manual motor
starter
BEA16-3
33
R
R
IEC
UL / CSA
AC-1
Rated
operational
current
General use rating
600 V AC
Main accessories
1SBC101292S0201
(Varistor) AC / DC
(Capacitor) AC
(Transil diode) DC
ABB | 4/31
AS09 ... AS16 3-pole contactors
4 to 7.5 kW
AC operated
1SBC101007F0014
Description
AS09-30-10
4
AS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and
220 V DC.
These contactors are of the block type design with:
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
5.5
7.5
24
24
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
20
7.5
20
10
20
V 50 Hz
V 60 Hz
24
24
-
120
230
230
400
400
24
24
-
120
230
230
400
400
24
24
-
120
230
230
400
400
Auxiliary Type
contacts
fitted
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Order code
Weight
Pkg
(1 pce)
AS09-30-10-20
AS09-30-01-20
AS09-30-10-16
AS09-30-01-16
AS09-30-10-26
AS09-30-01-26
AS09-30-10-28
AS09-30-01-28
AS12-30-10-20
AS12-30-01-20
AS12-30-10-16
AS12-30-01-16
AS12-30-10-26
AS12-30-01-26
AS12-30-10-28
AS12-30-01-28
AS16-30-10-20
AS16-30-01-20
AS16-30-10-16
AS16-30-01-16
AS16-30-10-26
AS16-30-01-26
AS16-30-10-28
AS16-30-01-28
1SBL101001R2010
1SBL101001R2001
1SBL101001R1610
1SBL101001R1601
1SBL101001R2610
1SBL101001R2601
1SBL101001R2810
1SBL101001R2801
1SBL111001R2010
1SBL111001R2001
1SBL111001R1610
1SBL111001R1601
1SBL111001R2610
1SBL111001R2601
1SBL111001R2810
1SBL111001R2801
1SBL121001R2010
1SBL121001R2001
1SBL121001R1610
1SBL121001R1601
1SBL121001R2610
1SBL121001R2601
1SBL121001R2810
1SBL121001R2801
kg
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
4/32 | ABB
2x
M4 8-32 UNC
50 1.97"
35 mm EN/IEC 60715
68 2.68"
AS09, AS12, AS16
5.5 0.22"
10 0.39"
60 2.36"
7 0.28"
45 1.77"
35 1.38"
ø 4.2 0.17"
1SBC101301S0201
Main dimensions
ASL09 ... ASL16 3-pole contactors
4 to 7.5 kW
DC operated
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
20
V DC
24
48
110
220
5.5
24
7.5
20
24
48
110
220
7.5
24
10
20
24
48
110
220
Auxiliary Type
contacts
fitted
Order code
Weight
4
Pkg
(1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
ASL09-30-10-81
ASL09-30-01-81
ASL09-30-10-83
ASL09-30-01-83
ASL09-30-10-86
ASL09-30-01-86
ASL09-30-10-88
ASL09-30-01-88
ASL12-30-10-81
ASL12-30-01-81
ASL12-30-10-83
ASL12-30-01-83
ASL12-30-10-86
ASL12-30-01-86
ASL12-30-10-88
ASL12-30-01-88
ASL16-30-10-81
ASL16-30-01-81
ASL16-30-10-83
ASL16-30-01-83
ASL16-30-10-86
ASL16-30-01-86
ASL16-30-10-88
ASL16-30-01-88
1SBL103001R8110
1SBL103001R8101
1SBL103001R8310
1SBL103001R8301
1SBL103001R8610
1SBL103001R8601
1SBL103001R8810
1SBL103001R8801
1SBL113001R8110
1SBL113001R8101
1SBL113001R8310
1SBL113001R8301
1SBL113001R8610
1SBL113001R8601
1SBL113001R8810
1SBL113001R8801
1SBL123001R8110
1SBL123001R8101
1SBL123001R8310
1SBL123001R8301
1SBL123001R8610
1SBL123001R8601
1SBL123001R8810
1SBL123001R8801
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
5.5 0.22"
10 0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
60 2.36"
7 0.28"
45 1.77"
1SBC101302S0201
Main dimensions
35 mm EN/IEC 60715
ASL09-30-10
ASL09 ... ASL16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC.
These contactors are of the block type design with:
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for
direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
68 2.68"
1SBC101010F0014
Description
ASL09, ASL12, ASL16
ABB | 4/33
AS09 ... AS16 2-stack 3-pole contactors
4 to 7.5 kW
AC operated
1SBC101332F0014
Description
AS09-30-32
4
AS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and
220 V DC.
These contactors are of the block type design with:
–– 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact
–– 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block. The auxiliary contact elements are
mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC operated
–– a comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
20
5.5
24
7.5
20
7.5
24
10
20
V 50 Hz
V 60 Hz
24
230
400
24
230
400
24
230
400
24
120
230
400
24
120
230
400
24
120
230
400
Auxiliary Type
contacts
fitted
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
AS09-30-32-20
AS09-30-32-16
AS09-30-32-26
AS09-30-32-28
AS12-30-32-20
AS12-30-32-16
AS12-30-32-26
AS12-30-32-28
AS16-30-32-20
AS16-30-32-16
AS16-30-32-26
AS16-30-32-28
Order code
Weight
Pkg
(1 pce)
1SBL101001R2032
1SBL101001R1632
1SBL101001R2632
1SBL101001R2832
1SBL111001R2032
1SBL111001R1632
1SBL111001R2632
1SBL111001R2832
1SBL121001R2032
1SBL121001R1632
1SBL121001R2632
1SBL121001R2832
kg
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
100.2 3.94"
72.5 2.85"
4/34 | ABB
44.2 1.74"
5.5 0.22"
1SBC101303S0201
AS09, AS12, AS16
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
ASL09 ... ASL16 2-stack 3-pole contactors
4 to 7.5 kW
DC operated
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
UL/CSA
3-phase
motor
rating
480 V
General
use
rating
600 V AC
hp
5
A
20
5.5
24
7.5
20
7.5
24
10
20
Rated control circuit
voltage
Uc
(1)
Auxiliary Type
contacts
fitted
Order code
4
Weight
Pkg
(1 pce)
kg
V DC
24
48
110
220
24
48
110
220
24
48
110
220
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
ASL09-30-32-81
ASL09-30-32-83
ASL09-30-32-86
ASL09-30-32-88
ASL12-30-32-81
ASL12-30-32-83
ASL12-30-32-86
ASL12-30-32-88
ASL16-30-32-81
ASL16-30-32-83
ASL16-30-32-86
ASL16-30-32-88
1SBL103001R8132
1SBL103001R8332
1SBL103001R8632
1SBL103001R8832
1SBL113001R8132
1SBL113001R8332
1SBL113001R8632
1SBL113001R8832
1SBL123001R8132
1SBL123001R8332
1SBL123001R8632
1SBL123001R8832
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
100.2 3.94"
5.5 0.22"
10
0.39"
1SBC101453S0201
7 0.28"
44.2 1.74"
72.5 2.85"
45 1.77"
35 mm EN/IEC 60715
ASL09-30-32
ASL09 ... ASL16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC.
These contactors are of the block type design with:
–– 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact
–– 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block. The auxiliary contact elements are
mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for
direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– a comprehensive range of accessories.
68 2.68"
1SBC101334F0014
Description
ASL09, ASL12, ASL16
ABB | 4/35
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Main accessories
Contactor and main accessories (other accessories available)
BEY16C-3
VM3
(optional)
BER16C-3
MS116
4
VM3
AS
ASL
Contactors
BEA16-3
AS
ASL
Contactors
RV5, RC5-1 or RT5
T16
AS
ASL
Contactors
T16
TEF3
CA3
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Main
poles
Built-in Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
AS09 ... AS16
3
3
3
3
3
3
1
0
3
1
0
3
1-pole CA3
AS09 ... AS16
ASL09 ... ASL16
ASL09 ... ASL16
0
0
0
0
0
0
0
1
2
0
1
2
Side-mounted accessories
Electronic timer
Mechanical interlock unit
(between 2 contactors)
TEF3
VM3
Surge suppressors
2 max.
or 1
+
1
+
RV5
or RC5-1
–
2 max.
–
or 1
+
1
1
+
+
RV5
RV5
or RC5-1
or RT5
1
+
RV5
or RT5
–
–
Overload relays fitting details (1)
Contactor types
AS09 … AS16
ASL09 … ASL16
Thermal overload relays
T16 (0.10...16 A)
1SBC101297S0201
The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.
(1) Direct mounting - No kit required.
4/36 | ABB
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Main accessories
Front-mounted instantaneous auxiliary contact blocks
1SBC101036F0014
For contactors
Auxiliary Type
contacts
Order code
Pkg
qty
Weight
(1 pce)
CA3-10
CA3-01
1SBN011010T1010
1SBN011010T1001
10
10
kg
0.011
0.011
Rated control circuit
voltage - Uc
V
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
ON-delay
AS09 … AS16, ASL09 … ASL16
24...240 V AC/DC
TEF3-ON
1SBN021012R1000
1
0.065
OFF-delay
AS09 … AS16, ASL09 … ASL16
24...240 V AC/DC
TEF3-OFF
1SBN021014R1000
1
0.065
For contactors
Type
Order code
Pkg
qty
AS09 … AS16, ASL09 … ASL16
VM3
1SBN031005T1000
10
Weight
(1 pce)
kg
0.002
Type
Order code
Pkg
qty
Weight
(1 pce)
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
Order code
Pkg
qty
1SBN081006T1000
10
AS09 … AS16
ASL09 … ASL16
CA3-10
1
0
0
1
Front-mounted electronic timer
1SBC101337F0014
For contactors
1SBC101069F0014
TEF3-ON
4
Mechanical interlock unit
1SBC574001F0301
VM3
RV5
Surge suppressors
For contactors
AS09 ... AS16,
ASL09 ... ASL16
1SBC101034F0014
AS09 ... AS16
ASL09 ... ASL16
BEA16-3
Rated control circuit
voltage - Uc
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
AC
●
●
●
●
●
●
●
●
–
–
–
–
–
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
1SBC101071F0014
Connecting links with manual motor starters
For contactors
Manual motor
starter
Type
AS09 … AS16
ASL09 … ASL16
MS116-0.16 ... MS116-16 BEA16-3
MS132-0.16 ... MS132-16
Weight
(1 pce)
kg
0.019
Connection sets for reversing contactors
BER16C-3
For contactors
Mechanical
interlock unit
Type
Order code
Pkg
qty
AS09 … AS16, ASL09 … ASL16
with or without VM3
BER16C-3
1SBN081012R1000
1
Weight
(1 pce)
kg
0.035
BEY16C-3
Connection sets for star-delta starting
For contactors
Mech. interlock unit
between Star & Delta
contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
AS09 … AS12, ASL09 … ASL12
with or without VM3
BEY16C-3
1SBN081018R2000
1
kg
0.041
Note: BEY16C-3 connection set includes two BB3 fixing clips, and an electrical interlocking when fitted on Star and Delta contactors
with built-in N.C. auxiliary contacts. BEY16C-3 can be used with or without VM3 mechanical interlock unit.
ABB | 4/37
1SBC101297S0201
1SBC101070F0014
Note: BER16C-3 connection set includes two BB3 fixing clips, and an electrical interlocking when fitted on contactors with built-in
N.C. auxiliary contacts. BER16C-3 can be used with or without VM3 mechanical interlock unit.
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
AS09
AS12
ASL09
ASL12
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
AS16
ASL16
22 A
2.5 mm²
25 A
4 mm²
25 A
4 mm²
22 A
18 A
15 A
2.5 mm²
24 A
20 A
16 A
24 A
20 A
16 A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
9
9
9
8
8
5
12 A
12 A
12 A
11 A
11 A
7A
15.7
15.5
15.5
13.6
12.5
9A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
2.2 kW
3 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
4 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
12 A
5.5 kW
16 A
7.5 kW
22 A
11 kW
25 A
230 A
100 A
65 A
50 A
22 A
250 A
124 A
75 A
55 A
24 A
250 A
124 A
75 A
55 A
24 A
1.2 W
0.3 W
1.2 W
0.5 W
AC operated
DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
A
A
A
A
A
A
A
A
A
A
A
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a
Rated operational power AC-8a
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,
in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
Power dissipation per pole
Max. electrical switching frequency
1s
10 s
30 s
1 min
15 min
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-4
155 A
90 A
1W
0.16 W
600 cycles/h
1200 cycles/h
300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101489S0201
4
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
4/38 | ABB
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
AC operated
DC operated
Standards
Max. operational voltage
NEMA size
Thermal current
NEMA continuous amp rating
115 V AC
NEMA maximum horse power ratings 1-phase, 60 Hz
230 V AC
200 V AC
230 V AC
460 V AC
575 V AC
NEMA maximum horse power ratings 3-phase, 60 Hz
UL / CSA general use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
120 V AC
240 V AC
120 V AC
240 V AC
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
AS09
ASL09
UL 508, CSA C22.2 N°14
690 V
00
9A
1/3 hp
1 hp
1 1/2 hp
1 1/2 hp
2 hp
2 hp
AS12
ASL12
AS16
ASL16
00
9A
1/3 hp
1 hp
1 1/2 hp
1 1/2 hp
2 hp
2 hp
0
18 A
1 hp
2 hp
3 hp
3 hp
5 hp
5 hp
20 A
AWG 12
20 A
AWG 12
20 A
AWG 12
7.2 A
8A
1/3 hp
1 hp
9.8 A
10 A
1/2 hp
1-1/2 hp
13.8 A
12 A
3/4 hp
2 hp
7.8 A
6.8 A
7.6 A
9A
2 hp
2 hp
5 hp
7-1/2 hp
7.8 A
9.6 A
11 A
11 A
2 hp
3 hp
7-1/2 hp
10 hp
11 A
15.2 A
14 A
11 A
3 hp
5 hp
10 hp
10 hp
40 A
J
50 A
60 A
4
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
For general use
For motor use
600 cycles/h
1200 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
A
A
C1
B1
B2
C2
Vibration withstand acc. to IEC 60068-2-6
Shock direction
A
B1
B2
C1
C2
AS09
ASL09
AS12
ASL12
AS16
ASL16
690 V
600 V
6 kV
-25...+60 °C
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
10 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
AS contactors - AC operated
ASL contactors - DC operated
20 g
20 g closed position / 10 g open position
10 g closed position / 5 g open position
15 g closed position / 5 g open position
15 g
10 g
20 g closed position / 9 g open position
15 g closed position / 8 g open position
20 g closed position / 14 g open position
14 g closed position / 8 g open position
5...300 Hz / 3 g closed position / 2 g open position
ABB | 4/39
1SBC101489S0201
Contactor types
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Technical data
Magnet system characteristics for AS09 … AS16 contactors
Contactor types
Coil operating limits
AC operated
AC supply
acc. to IEC 60947-4-1
AC control voltage Rated control circuit voltage Uc
at 50 Hz
at 60 Hz
Coil consumption Average pull-in value 50 Hz
60 Hz
50/60 Hz
Average holding value 50 Hz
60 Hz
50/60 Hz
4
Drop-out voltage
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
AS09
AS12
AS16
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
24...415 V
24...415 V
33 VA
33 VA
33 VA
6.5 VA / 1.5 W
5 VA / 1.2 W
6.5 VA / 1.5 W
Approx. 30...50 % of Uc
9...24 ms
6...18 ms
5...19 ms
7...22 ms
(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3
Magnet system characteristics for ASL09 … ASL16 contactors
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
DC control voltage
Drop-out voltage
Coil time constant
DC operated
DC supply
ASL09
ASL12
ASL16
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
Rated control circuit voltage Uc
12...240 V DC
Average pull-in value 3 W
Coil consumption
Average holding value 3 W
Approx. 10...40 % of Uc
L/R 12 ms
Open
L/R 40 ms
Closed
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
36...59 ms
31...53 ms
13...17 ms
15...20 ms
(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
AS09
ASL09
Mounting positions
AS12
ASL12
Pos. 2
+30°
AS16
ASL16
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 5
The contactors can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101489S0201
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
4/40 | ABB
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Technical data
Connecting characteristics
Contactor types
AC operated
DC operated
AS09
ASL09
AS12
ASL12
AS16
ASL16
Main terminals
Screw terminals with cable clamp
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Bars or lugs
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Recommended
Max.
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Coil terminals
Recommended
Max.
Built-in auxiliary terminals Recommended
Max.
Degree of protection
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
0.75...4 mm²
0.75...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
7.7 mm
3.2 mm
AWG 18...12
9 mm
1.00 Nm / 9 lb.in
1.20 Nm
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
7.7 mm
3.2 mm
AWG 18...14
1.00
1.20
1.00
1.20
4
Nm / 9 lb.in
Nm
Nm / 9 lb.in
Nm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
IP20
Delivered in open position, screws of unused terminals must be tightened
M3
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101489S0201
All terminals
Screw terminals
All terminals
ABB | 4/41
AS09 ... AS16 and
ASL09 ... ASL16 3-pole contactors
Technical data
Built-in auxiliary contacts according to IEC
Contactor types
AC operated
DC operated
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
for 1.0 s
for 0.1 s
AC-15
DC-13
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
AS12
ASL12
AS16
ASL16
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
10 A
100 A
140 A
12 V / 3 mA
10-7
1.5 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux.
contact blocks) are mechanically linked contacts.
Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA3 aux. contact blocks) are
mirror contacts.
Mirror contacts
acc. to annex F of IEC 60947-4-1
Built-in auxiliary contacts according to UL / CSA
Contactor types
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
AC operated
DC operated
AS09
ASL09
600 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
AS12
ASL12
AS16
ASL16
1SBC101489S0201
4
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
AS09
ASL09
690 V
50 / 60 Hz
10 A
4/42 | ABB
Notes
N15
4
ABB | 4/43
AS09 ... AS16 and ASL09 ... ASL16 3-pole contactors
Electrical durability
AS
L0
A
9
AS S12
16 , A
, A SL
SL 12
16 ,
A
AS SL0
16 9,
, A AS
SL 12
16 , A
4
3
2
1 3 5 7 9
1
0.6
0.5
0.3
0.2
9
7
5
3
1
9
7
9
7
5
3
1
5
3
0.1
1 3 5 7 9
1
2
3
5
9 10
20
30
Breaking current Ic (A)
Example:
Breaking current = 9 A.
On the opposite curve at intersection " " 9 A the corresponding value for the electrical durability is approximately 0.6 millions
operating cycles.
1SBC101931S0201
4
AS
Millions of
operating
cycles
09
SL
12
,
Electrical durability for AC-1 utilization category - Ue ≤ 690 V
Note: AC-1 maximum current is selected according to ambient temperature. Please see technical data.
Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of
the load. Maximum electrical switching frequency: 600 cycles / hour.
4/44 | ABB
AS09 ... AS16 and ASL09 ... ASL16 3-pole contactors
Electrical durability
AS
Millions of
operating
cycles
09
AS , A
12 SL
, A 09
SL
AS
12
16
,A
SL
16
Electrical durability for AC-3 utilization category - Ue ≤ 440 V - Ambient temperature ≤ 60 °C
Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current). Maximum electrical switching frequency: 1200 cycles / hour.
10
4
5
3
9
7
5
3
1
2
9
7
5
3
1
1
0.5
0.3
0.2
1
2
3
4
5
10
3
5
7
9
20
Breaking current Ic (A)
1SBC101930S0201
Example:
Breaking current = 4 A.
On the opposite curve at intersection " " 4 A the corresponding value for the electrical durability is approximately 3 millions
operating cycles.
ABB | 4/45
VAS09 ... VAS16 3-pole reversing contactors
4 to 7.5 kW
AC operated
1SBC101080F0014
Description
VAS09 ... VAS16 reversing contactors are used for controlling 3-phase motors up to 690 V AC.
These reversing contactors include 2 AS09 ... AS16 contactors fitted with 1 N.C. auxiliary contact,
1 VM3 mechanical interlock and BER16C-3 reversing connection set including electrical interlocking.
Up to 2 add-on CA3 1-pole auxiliary contact blocks can be mounted per contactor.
The reversing contactors are available with or without surge suppressor mounted on each contactor.
Ordering details
VAS09EM
4
IEC
Rated operational
power
400 V
AC-3
kW
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
voltage
Uc
(1)
hp
V 50 Hz
Auxiliary Type
contacts
fitted
Order code
Pkg
qty
V 60 Hz
Weight
(1 pce)
kg
Reversing contactors without integrated surge suppressor
4
5
24
24
0 2 VAS09EM-20M
120
0 2 VAS09EM-16M
230
230
0 2 VAS09EM-26M
400
400
0 2 VAS09EM-28M
5.5
7.5
24
24
0 2 VAS12EM-20M
120
0 2 VAS12EM-16M
230
230
0 2 VAS12EM-26M
400
400
0 2 VAS12EM-28M
7.5
10
24
24
0 2 VAS16EM-20M
120
0 2 VAS16EM-16M
230
230
0 2 VAS16EM-26M
400
400
0 2 VAS16EM-28M
1SBK103600M2000
1SBK103600M1600
1SBK103600M2600
1SBK103600M2800
1SBK113600M2000
1SBK113600M1600
1SBK113600M2600
1SBK113600M2800
1SBK123600M2000
1SBK123600M1600
1SBK123600M2600
1SBK123600M2800
18
18
18
18
18
18
18
18
18
18
18
18
0.480
0.480
0.480
0.480
0.480
0.480
0.480
0.480
0.480
0.480
0.480
0.480
Reversing contactors with RC5-1 integrated surge suppressor
4
5
24
24
0 2 VAS09SEM-20M
120
0 2 VAS09SEM-16M
230
230
0 2 VAS09SEM-26M
400
400
0 2 VAS09SEM-28M
5.5
7.5
24
24
0 2 VAS12SEM-20M
120
0 2 VAS12SEM-16M
230
230
0 2 VAS12SEM-26M
400
400
0 2 VAS12SEM-28M
7.5
10
24
24
0 2 VAS16SEM-20M
120
0 2 VAS16SEM-16M
230
230
0 2 VAS16SEM-26M
400
400
0 2 VAS16SEM-28M
1SBK103800M2000
1SBK103800M1600
1SBK103800M2600
1SBK103800M2800
1SBK113800M2000
1SBK113800M1600
1SBK113800M2600
1SBK113800M2800
1SBK123800M2000
1SBK123800M1600
1SBK123800M2600
1SBK123800M2800
18
18
18
18
18
18
18
18
18
18
18
18
0.510
0.510
0.510
0.510
0.510
0.510
0.510
0.510
0.510
0.510
0.510
0.510
(1) Other control voltages see voltage code table.
Note: Minimum switchover delay of 50 ms must be introduced between respective opening and closing of AC operated reversing
contactors.
mm, inches
72.5 2.85"
4/46 | ABB
35 mm EN/IEC 60715
5.5 0.22"
10 0.39"
2x
M4 8-32 UNC
80 3.15"
ø 4.2 0.17"
1SBC101462S0201
VAS09, VAS12, VAS16
68 2.68"
78.5 3.09"
7 0.28"
50 1.97"
90 3.54"
60 2.36"
Main dimensions
VASL09 ... VASL16 3-pole reversing contactors
4 to 7.5 kW
DC operated
1SBC101082F0014
Description
VASL09 ... VASL16 reversing contactors are used for controlling 3-phase motors up to 690 V AC.
These reversing contactors include 2 ASL09 ... ASL16 contactors fitted with 1 N.C. auxiliary contact,
1 VM3 mechanical interlock and BER16C-3 reversing connection set including electrical interlocking.
Up to 2 add-on CA3 1-pole auxiliary contact blocks can be mounted per contactor.
The reversing contactors are available with or without surge suppressor mounted on each contactor.
Ordering details
IEC
Rated operational
power
400 V
AC-3
kW
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
voltage
Uc
(1)
hp
V DC
Auxiliary Type
contacts
fitted
Order code
Pkg
qty
Weight
(1 pce)
4
kg
Reversing contactors without integrated surge suppressor
4
5
24
0 2 VASL09EM-81M
48
0 2 VASL09EM-83M
110
0 2 VASL09EM-86M
220
0 2 VASL09EM-88M
5.5
7.5
24
0 2 VASL12EM-81M
48
0 2 VASL12EM-83M
110
0 2 VASL12EM-86M
220
0 2 VASL12EM-88M
7.5
10
24
0 2 VASL16EM-81M
48
0 2 VASL16EM-83M
110
0 2 VASL16EM-86M
220
0 2 VASL16EM-88M
1SBK103700M8100
1SBK103700M8300
1SBK103700M8600
1SBK103700M8800
1SBK113700M8100
1SBK113700M8300
1SBK113700M8600
1SBK113700M8800
1SBK123700M8100
1SBK123700M8300
1SBK123700M8600
1SBK123700M8800
18
18
18
18
18
18
18
18
18
18
18
18
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.600
Reversing contactors with RV5 integrated surge suppressor
4
5
24
0 2 VASL09SEM-81M
48
0 2 VASL09SEM-83M
110
0 2 VASL09SEM-86M
220
0 2 VASL09SEM-88M
5.5
7.5
24
0 2 VASL12SEM-81M
48
0 2 VASL12SEM-83M
110
0 2 VASL12SEM-86M
220
0 2 VASL12SEM-88M
7.5
10
24
0 2 VASL16SEM-81M
48
0 2 VASL16SEM-83M
110
0 2 VASL16SEM-86M
220
0 2 VASL16SEM-88M
1SBK103900M8100
1SBK103900M8300
1SBK103900M8600
1SBK103900M8800
1SBK113900M8100
1SBK113900M8300
1SBK113900M8600
1SBK113900M8800
1SBK123900M8100
1SBK123900M8300
1SBK123900M8600
1SBK123900M8800
18
18
18
18
18
18
18
18
18
18
18
18
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
5.5 0.22"
10 0.39"
2x
M4 8-32 UNC
80 3.15"
ø 4.2 0.17"
1SBC101473S0201
90 3.54"
60 2.36"
Main dimensions
78.5 3.09"
VASL09EM
VASL09, VASL12, VASL16
ABB | 4/47
VAS09 ... VAS16 and
VASL09 ... VASL16 3-pole reversing contactors
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
VAS09
VAS12
VASL09
VASL12
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
VAS16
VASL16
22 A
2.5 mm²
25 A
4 mm²
25 A
4 mm²
220-230-240 V
400 V
415 V
440 V
500 V
690 V
9
9
9
8
8
5
12 A
12 A
12 A
11 A
11 A
7A
15.7
15.5
15.5
13.6
12.5
9A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
2.2 kW
3 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
AC operated
DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
M
3
3-phase motors
A
A
A
A
A
A
A
A
A
A
A
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection device for contactors
4 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,
in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
25 A
230 A
100 A
65 A
1 min 50 A
15 min 22 A
1s
10 s
30 s
at 440 V
at 690 V
250 A
124 A
75 A
55 A
24 A
250 A
124 A
75 A
55 A
24 A
0.3 W
0.5 W
155 A
90 A
Power dissipation per pole
Max. electrical switching frequency
Ie / AC-3
AC-3
0.16 W
600 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101500S0201
4
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
4/48 | ABB
VAS09 ... VAS16 and
VASL09 ... VASL16 3-pole reversing contactors
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
VAS12
VASL12
VAS16
VASL16
230 V AC
200 V AC
230 V AC
460 V AC
575 V AC
VAS09
VASL09
UL 508, CSA C22.2 N°14
690 V
00
9A
1/3 hp
1 hp
1 1/2 hp
1 1/2 hp
2 hp
2 hp
00
9A
1/3 hp
1 hp
1 1/2 hp
1 1/2 hp
2 hp
2 hp
0
18 A
1 hp
2 hp
3 hp
3 hp
5 hp
5 hp
120 V AC
240 V AC
120 V AC
240 V AC
7.2 A
8A
1/3 hp
1 hp
9.8 A
10 A
1/2 hp
1-1/2 hp
13.8 A
12 A
3/4 hp
2 hp
7.8 A
6.8 A
7.6 A
9A
2 hp
2 hp
5 hp
7-1/2 hp
7.8 A
9.6 A
11 A
11 A
2 hp
3 hp
7-1/2 hp
10 hp
11 A
15.2 A
14 A
11 A
3 hp
5 hp
10 hp
10 hp
40 A
J
50 A
60 A
AC operated
DC operated
Standards
Max. operational voltage
NEMA size
Thermal current
NEMA continuous amp rating
115 V AC
NEMA maximum horse power ratings 1-phase, 60 Hz
NEMA maximum horse power ratings 3-phase, 60 Hz
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
4
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
For motor use
600 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
VAS09
VASL09
VAS12
VASL12
VAS16
VASL16
690 V
600 V
6 kV
-25...+60 °C
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
5 millions operating cycles
1800 cycles/h
1SBC101500S0201
Contactor types
ABB | 4/49
VAS09 ... VAS16 and
VASL09 ... VASL16 3-pole reversing contactors
Technical data
Magnet system characteristics for VAS09 … VAS16 contactors
Contactor types
Coil operating limits
AC operated
acc. to IEC 60947-4-1
AC control voltage Rated control circuit voltage Uc
at 50 Hz
at 60 Hz
Coil consumption Average pull-in value 50 Hz
60 Hz
50/60 Hz
Average holding value 50 Hz
60 Hz
50/60 Hz
4
VAS09
VAS12
VAS16
AC supply
Drop-out voltage
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
24...415 V
24...415 V
33 VA
33 VA
33 VA
6.5 VA / 1.5 W
5 VA / 1.2 W
6.5 VA / 1.5 W
Approx. 30...50 % of Uc
9...24 ms
6...18 ms
5...19 ms
7...22 ms
(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.
Magnet system characteristics for VASL09 … VASL16 contactors
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
DC control voltage
Drop-out voltage
Coil time constant
DC operated
VASL09
VASL12
VASL16
DC supply
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
Rated control circuit voltage Uc
12...240 V DC
Average pull-in value 3 W
Coil consumption
Average holding value 3 W
Approx. 10...40 % of Uc
L/R 12 ms
Open
L/R 40 ms
Closed
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
36...59 ms
31...53 ms
13...17 ms
15...20 ms
(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
VAS09
VASL09
Mounting positions
VAS12
VASL12
Pos. 2
Pos. 4
-30°
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
The reversing contactors can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101500S0201
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
+30°
VAS16
VASL16
4/50 | ABB
VAS09 ... VAS16 and
VASL09 ... VASL16 3-pole reversing contactors
Technical data
Connecting characteristics
Contactor types
AC operated
DC operated
VAS09
VASL09
VAS12
VASL12
VAS16
VASL16
Main terminals
Screw terminals with cable clamp
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Recommended
Max.
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Coil terminals
Recommended
Max.
Built-in auxiliary terminals Recommended
Max.
Degree of protection
1x
1x
1x
1x
0.75...4 mm²
0.75...2.5 mm²
0.75...1.5 mm²
AWG 18...12
9 mm
1.00 Nm / 9 lb.in
1.20 Nm
1x
1x
1x
1x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
AWG 18...14
9 mm
1.00
1.20
1.00
1.20
4
Nm / 9 lb.in
Nm
Nm / 9 lb.in
Nm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
IP20
Delivered in open position, screws of unused terminals must be tightened
M3
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101500S0201
All terminals
Screw terminals
All terminals
ABB | 4/51
AS09 ... AS16 3-pole contactors
Terminal marking and positioning
AS contactors - AC operated
Standard devices without addition of auxiliary contacts
1L1 3L2 5L3 13
NC
NO
NC
2T1 4T2 6T3 14
2T1 4T2 6T3 22
A2
AS09 ... AS16-30-10
1L1 3L2 5L3 13
A1
A1
1L1
3L2
5L3
13
NO
A2
2T1
4T2
6T3
NO
14
A2
AS09 ... AS16-30-01
AS09 ... AS16-30-10
A1
1L1
3L2
5L3
21
NC
A2
2T1
4T2
6T3
NC
22
AS09 ... AS16-30-01
A1
NO
21NC 31NC 43NO 53NO
NC NC NO NO
22NC 32NC 44NO 54NO
NO
2T1 4T2 6T3 14
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
NO
54
A2
AS09 … AS16-30-32
AS09 ... AS16-30-32
Other possible contact combinations with auxiliary contact blocks added by the user
1L1 3L2 5L3 13
1L1 3L2 5L3 13
A1
NO
A1
NO
21
2-
-1
=
NC
+
22
2-
-2
NO
2T1 4T2 6T3 14
2T1 4T2 6T3 14
A2
=
21
33
NO
22
34
1L1 3L2 5L3 13
A1
3L2
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
+
Combination 11
CA3-01
A1
NO
2-
3-
-1
=
+
2-
3-
NO
2T1 4T2 6T3 14
1L1
A2
AS09 ... AS16-30-10
NO
NC
A1
NO
Combination 11
1L1 3L2 5L3 13
NC
NC
-3
+
-2
NO
-4
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
NO
2T1 4T2 6T3 14
A2
Combination 21
=
A2
AS09 ... AS16-30-10
CA3 1-pole auxiliary contact blocks
+
CA3-01
+
CA3-10
Combination 21
TEF3 front-mounted electronic timer
55
-1
-3
-3
NO
-1
NO
NC
-4
56
NC
CA3-10
4/52 | ABB
-2
CA3-01
68
NO
55
NC
67
NO
NC
56
NO
68
NC
-2
-4
67
TEF3
1SBC101404S0201
4
1L1 3L2 5L3 21
A1
NO
ASL09 ... ASL16 3-pole contactors
Terminal marking and positioning
ASL contactors - DC operated (the polarity A1+, A2- must be respected)
Standard devices without addition of auxiliary contacts
1L1 3L2 5L3 13
1L1 3L2 5L3 21
A1+
NO
NC
NO
NC
2T1 4T2 6T3 14
2T1 4T2 6T3 22
A2-
ASL09 ... ASL16-30-10
A1+
A1+
1L1
3L2
5L3
13
NO
A2-
2T1
4T2
6T3
NO
14
A2-
ASL09 ... ASL16-30-01
ASL09 ... ASL16-30-10
A1+
1L1
3L2
5L3
21
NC
A2-
2T1
4T2
6T3
NC
22
ASL09 ... ASL16-30-01
4
1L1 3L2 5L3 13 A1+
NO
21NC 31NC 43NO 53NO
NC NC NO NO
22NC 32NC 44NO 54NO
NO
2T1 4T2 6T3 14
A1+
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
A2-
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
NO
54
A2-
ASL09 … ASL16-30-32
ASL09 ... ASL16-30-32
Other possible contact combinations with auxiliary contact blocks added by the user
1L1 3L2 5L3 13
A1+
NO
A1+
NO
21
2-
-1
=
NC
+
22
2-
-2
NO
2T1 4T2 6T3 14
=
21
33
NO
22
34
A2-
1L1 3L2 5L3 13
A1+
3L2
5L3
13
NO
21
NC
A2-
2T1
4T2
6T3
NO
14
NC
22
A1+
NO
2-
3-
-1
=
+
2-
3-
NO
2T1 4T2 6T3 14
1L1
Combination 11
ASL09 ... ASL16-30-10 + CA3-01
NO
NC
A1+
NO
2T1 4T2 6T3 14
A2-
Combination 11
1L1 3L2 5L3 13
NC
NC
-3
+
-2
NO
-4
A1+
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2-
2T1
4T2
6T3
NO
14
NC
22
NO
34
NO
2T1 4T2 6T3 14
A2-
Combination 21
=
A2-
ASL09 ... ASL16-30-10 + CA3-01
CA3 1-pole auxiliary contact blocks
+
CA3-10
Combination 21
TEF3 front-mounted electronic timer
55
-1
-3
-3
NO
-1
NO
NC
-4
-2
CA3-01
67
68
NO
55
NC
67
NO
NC
56
NO
68
NC
-2
-4
CA3-10
56
NC
1SBC101404S0201
1L1 3L2 5L3 13
TEF3
ABB | 4/53
AS09 ... AS16 3-pole contactors
mm, inches
100.2 100.2
3.94" 3.94"
50 1.97"
35 1.38"
35 1.38"
2x
2x
ø 4.2 0.17"
M4 8-32
ø 4.2 0.17"
M4UNC
8-32 UNC
50 1.97"
60 2.36"
5.5 0.22"
5.5 0.22"
10
10
0.39" 0.39"
60 2.36"
35 mm EN/IEC 60715
7 0.28"7 0.28"
44.2 1.74"
72.5 2.85"
72.5 2.85"
35 mm EN/IEC 60715
60 2.36"
68 2.68"
50 1.97"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
AS09, AS12, AS16
AS09, AS12, AS16
+ CA3 front-mounted 1-pole auxiliary contact block
128.1 5.04"
72.5 2.85"
10
0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
50 1.97"
5.5 0.22"
60 2.36"
1.1 0.05"
44.2 1.74"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
44.4 1.75"
45 1.77"
AS09, AS12, AS16
+ TEF3 electronic timer
100.2 3.94"
72.5 2.85"
44.2 1.74"
35 mm EN/IEC 60715
5.5 0.22"
35 1.38"
ø 4.2 0.17"
50 1.97"
2x
M4 8-32 UNC
7 0.28"
60 2.36"
45 1.77"
68 2.68"
AS09 ... 16-30-32
1SBC101405S0201
4
35 1.38"
2x
45 1.77"
45 1.77"
ø 4.2 0.17"
M4 8-32 UNC
10 0.39"
44.2 1.74"
72.5 2.85"
7 0.28"
45 1.77"
68 2.68"
Main dimensions
4/54 | ABB
AS09 ... AS16 3-pole contactors
Main dimensions
mm, inches
72.5 2.85"
80 3.15"
4x
M4 8-32 UNC
10 0.39"
5.5 0.22"
60 2.36"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
ø 4.2 0.17"
50 1.97"
90 3.54"
4
AS09, AS12, AS16
+ VM3 mechanical interlock unit including two BB3 fixing clips
72.5 2.85"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
68 2.68"
78.5 3.09"
7 0.28"
80 3.15"
ø 4.2 0.17"
50 1.97"
90 3.54"
AS09, AS12, AS16
+ BER16C-3 connection set for reversing starter including two BB3 fixing clips
72.5 2.85"
10 0.39"
5.5 0.22"
4x
M4 8-32 UNC
125 4.92"
ø 4.2 0.17"
50 1.97"
35 mm EN/IEC 60715
68 2.68"
78.5 3.09"
7 0.28"
60 2.36"
135 5.31"
1SBC101405S0201
AS09, AS12, AS16
+ BEY16C-3 connection set for star-delta starter including four BB3 fixing clips
ABB | 4/55
ASL09 ... ASL16 3-pole contactors
mm, inches
100.2 3.94"
72.5 2.85"
35 1.38"
ø 4.2 0.17"
60 2.36"
5.5 0.22"
35 1.38"
10
2x
2x
4.2 0.17"
0.39" M4 8-32 UNC M4ø8-32
UNC
60 2.36"
5.5 0.22"
72.5 2.85" 10
0.39"
7 0.28"
44.2 1.74"
7 0.28"
35 mm EN/IEC 60715
45 1.77"
68 2.68"
60 2.36"
68 2.68"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
ASL09, ASL12, ASL16
ASL09, ASL12, ASL16
+ CA3 front-mounted 1-pole auxiliary contact block
128.1 5.04"
72.5 2.85"
10
0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
1.1 0.05"
5.5 0.22"
44.4 1.75"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
60 2.36"
45 1.77"
ASL09, ASL12, ASL16
+ TEF3 electronic timer
100.2 3.94"
5.5 0.22"
10
0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
7 0.28"
44.2 1.74"
72.5 2.85"
45 1.77"
68 2.68"
ASL09 ... 16-30-32
1SBC101406S0201
4
35 1.38"
45 1.77"
ø 4.2 0.17"
2x
M4 8-32 UNC
10 0.39"
44.2 1.74"
100.2 3.94"
72.5 2.85"
7 0.28"
45 1.77"
35 mm EN/IEC 60715
Main dimensions
4/56 | ABB
ASL09 ... ASL16 3-pole contactors
Main dimensions
mm, inches
72.5 2.85"
7 0.28"
4x
M4 8-32 UNC
10 0.39"
5.5 0.22"
80 3.15"
ø 4.2 0.17"
60 2.36"
68 2.68"
35 mm EN/IEC 60715
90 3.54"
4
ASL09, ASL12, ASL16
+ VM3 mechanical interlock unit including two BB3 fixing clips
90 3.54"
72.5 2.85"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
80 3.15"
ø 4.2 0.17"
60 2.36"
35 mm EN/IEC 60715
68 2.68"
78.5 3.09"
7 0.28"
ASL09, ASL12, ASL16
+ BER16C-3 connection set for reversing starter including two BB3 fixing clips
72.5 2.85"
35 mm EN/IEC 60715
68 2.68"
78.5 3.09"
7 0.28"
10 0.39"
5.5 0.22"
4x
M4 8-32 UNC
125 4.92"
ø 4.2 0.17"
60 2.36"
135 5.31"
1SBC101406S0201
ASL09, ASL12, ASL16
+ BEY16C-3 connection set for star-delta starter including four BB3 fixing clips
ABB | 4/57
VAS09 ... VAS16 reversing contactors
mm, inches
72.5 2.85"
4
35 mm EN/IEC 60715
68 2.68"
78.5 3.09"
7 0.28"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
80 3.15"
ø 4.2 0.17"
50 1.97"
90 3.54"
60 2.36"
Main dimensions
VAS09, VAS12, VAS16
100.2 3.94"
72.5 2.85"
5.5 0.22"
80 3.15"
ø 4.2 0.17"
50 1.97"
2x
M4 8-32 UNC
10 0.39"
60 2.36"
35 mm EN/IEC 60715
68 2.68"
78.5 3.09"
7 0.28"
44.2 1.74"
90 3.54"
1SBC101407S0201
VAS09, VAS12, VAS16
+ CA3 front-mounted 1-pole auxiliary contact block
4/58 | ABB
VASL09 ... VASL16 reversing contactors
mm, inches
72.5 2.85"
90 3.54"
68 2.68"
35 mm EN/IEC 60715
78.5 3.09"
7 0.28"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
80 3.15"
ø 4.2 0.17"
60 2.36"
Main dimensions
4
VASL09, VASL12, VASL16
100.2 3.94"
72.5 2.85"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
80 3.15"
ø 4.2 0.17"
60 2.36"
68 2.68"
35 mm EN/IEC 60715
VASL09, VASL12, VASL16
+ CA3 front-mounted 1-pole auxiliary contact block
1SBC101408S0201
78.5 3.09"
7 0.28"
44.2 1.74"
90 3.54"
ABB | 4/59
Contactor relays
Main accessories
NS, NSL
Contactor relays
4
4-pole contactor relays
8-pole contactor relays
RV5, RT5 or RC5-1
Surge suppressor
RV5, RT5 or RC5-1
Surge suppressor
CA-3
1-pole auxiliary contact block
NS
NSL
Contactor relays
1SBC101409S0201
NS
NSL
Contactor relays
4/60 | ABB
Contactor relays
Screw terminals
NSL
NS
AC control voltage
NS22E
NS31E
NS40E
DC control voltage
NSL22E
NSL31E
NSL40E
2 N.O. + 2 N.C.
3 N.O. + 1 N.C.
4 N.O.
NS
4
NSL
AC control voltage
NS44E
NS53E
NS62E
NS71E
NS80E
DC control voltage
NSL44E
NSL53E
NSL62E
NSL71E
NSL80E
4 N.O. + 4 N.C.
5 N.O. + 3 N.C.
6 N.O. + 2 N.C.
7 N.O. + 1 N.C.
8 N.O.
Control circuit switching
Rated operational current
AC-15
IEC
DC-13
240 V
4A
400 V
3A
690 V
2A
24 V
250 V
UL / CSA
Pilot Duty
6 A / 144 W
0.27 A / 68 W
A600, Q300
Main accessories
Auxiliary
Front mounting
blocks
Surge
suppressors
1-pole CA3-10 or CA3-01
Side-mounted
RV5
(Varistor) AC / DC
(without additional
RC5-1
(Capacitor) AC
width)
RT5
(Transil diode) DC
1SBC101409S0201
contact
ABB | 4/61
NS contactor relays
AC operated
1SBC101012F0014
Description
NS22E
NS contactor relays are used for switching auxiliary and control circuits.
These contactor relays are designed with:
–– 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
Ordering details
Number of contacts
1st stack
Rated control circuit
voltage
Uc
(1)
2nd stack
4
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
V 50 Hz
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
V 60 Hz
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
Type
NS22E-20
NS22E-16
NS22E-26
NS22E-28
NS31E-20
NS31E-16
NS31E-26
NS31E-28
NS40E-20
NS40E-16
NS40E-26
NS40E-28
NS44E-20
NS44E-16
NS44E-26
NS44E-28
NS53E-20
NS53E-16
NS53E-26
NS53E-28
NS62E-20
NS62E-16
NS62E-26
NS62E-28
NS71E-20
NS71E-16
NS71E-26
NS71E-28
NS80E-20
NS80E-16
NS80E-26
NS80E-28
Order code
Weight
1SBH101001R2022
1SBH101001R1622
1SBH101001R2622
1SBH101001R2822
1SBH101001R2031
1SBH101001R1631
1SBH101001R2631
1SBH101001R2831
1SBH101001R2040
1SBH101001R1640
1SBH101001R2640
1SBH101001R2840
1SBH101001R2044
1SBH101001R1644
1SBH101001R2644
1SBH101001R2844
1SBH101001R2053
1SBH101001R1653
1SBH101001R2653
1SBH101001R2853
1SBH101001R2062
1SBH101001R1662
1SBH101001R2662
1SBH101001R2862
1SBH101001R2071
1SBH101001R1671
1SBH101001R2671
1SBH101001R2871
1SBH101001R2080
1SBH101001R1680
1SBH101001R2680
1SBH101001R2880
Pkg
(1 pce)
kg
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
100.2 3.94"
2 x M4 8-32 UNC
72.5 2.85"
35 1.38"
NS22E, NS31E, NS40E
4/62 | ABB
5.5 0.22"
NS44E, NS53E, NS62E, NS71E, NS80E
ø 4.2 0.17"
44.2 1.74"
35 mm EN/IEC 60715
5.5 0.22"
68 2.68"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
50 1.97"
45 1.77"
1SBC101475S0201
72.5 2.85"
7 0.28"
45 1.77"
60 2.36"
Main dimensions
NSL contactor relays
DC operated
Ordering details
Number of contacts
1st stack
A1+
13
NO
21
NC
31
NC
43
NO
NO
14
NC
22
NC
32
NO
44
13
NO
21
NC
33
NO
43
NO
NO
14
NC
22
NO
34
NO
44
13
NO
23
NO
33
NO
43
NO
NO
14
NO
24
NO
34
NO
44
A1+
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
A2-
A1+
A2-
A1+
A2-
Rated control circuit
voltage
Uc
(1)
V DC
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
2nd stack
Type
NSL22E-81
NSL22E-83
NSL22E-86
NSL22E-88
NSL31E-81
NSL31E-83
NSL31E-86
NSL31E-88
NSL40E-81
NSL40E-83
NSL40E-86
NSL40E-88
NSL44E-81
NSL44E-83
NSL44E-86
NSL44E-88
NSL53E-81
NSL53E-83
NSL53E-86
NSL53E-88
NSL62E-81
NSL62E-83
NSL62E-86
NSL62E-88
NSL71E-81
NSL71E-83
NSL71E-86
NSL71E-88
NSL80E-81
NSL80E-83
NSL80E-86
NSL80E-88
Order code
Weight
1SBH103001R8122
1SBH103001R8322
1SBH103001R8622
1SBH103001R8822
1SBH103001R8131
1SBH103001R8331
1SBH103001R8631
1SBH103001R8831
1SBH103001R8140
1SBH103001R8340
1SBH103001R8640
1SBH103001R8840
1SBH103001R8144
1SBH103001R8344
1SBH103001R8644
1SBH103001R8844
1SBH103001R8153
1SBH103001R8353
1SBH103001R8653
1SBH103001R8853
1SBH103001R8162
1SBH103001R8362
1SBH103001R8662
1SBH103001R8862
1SBH103001R8171
1SBH103001R8371
1SBH103001R8671
1SBH103001R8871
1SBH103001R8180
1SBH103001R8380
1SBH103001R8680
1SBH103001R8880
Pkg
(1 pce)
kg
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
4
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
100.2 3.94"
2 x M4 8-32 UNC
72.5 2.85"
45 1.77"
35 1.38"
NSL22E, NSL31E, NSL40E
5.5 0.22"
ø 4.2 0.17"
44.2 1.74"
35 mm EN/IEC 60715
5.5 0.22"
68 2.68"
7 0.28"
NSL44E, NSL53E, NSL62E, NSL71E, NSL80E
ABB | 4/63
1SBC101479S0201
72.5 2.85"
7 0.28"
45 1.77"
60 2.36"
Main dimensions
35 mm EN/IEC 60715
NSL22E
NSL contactor relays are used for switching auxiliary and control circuits.
These contactor relays are designed with:
–– 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: low coil consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable
for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
68 2.68"
1SBC101018F0014
Description
NS and NSL contactor relays
Main accessories
Contactor relays and main accessories (other accessories available)
4-pole contactor relay
RV5, RC5-1 or RT5
4
CA3
NS
NSL
Contactor relays
8-pole contactor relay
RV5, RC5-1 or RT5
TEF3
NS
NSL
Contactor relays
Main accessory fitting details
Contactor
types
Front-mounted accessories
Auxiliary contact blocks
Main
poles
Side-mounted accessories
Electronic timer
1-pole CA3
2
3
4
4
5
6
7
8
2
3
4
4
5
6
7
8
2
1
0
4
3
2
1
0
2
1
0
4
3
2
1
0
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
2 max.
TEF3
or
–
2 max.
–
1
Surge suppressors
+
–
or
1
–
+
RV5
or RC5-1
RV5
or RC5-1
RV5
or RT5
RV5
or RT5
1SBC101298S0201
NS..
NS..
NS..
NS..
NS..
NS..
NS..
NS..
NSL..
NSL..
NSL..
NSL..
NSL..
NSL..
NSL..
NSL..
4/64 | ABB
NS and NSL contactor relays
Main accessories
Front-mounted instantaneous auxiliary contact blocks
1SBC101036F0014
For contactor relays
Auxiliary Type
contacts
NS, NSL
1
0
CA3-10
0
1
CA3-10
CA3-01
Order code
Pkg
qty
Weight
(1 pce)
1SBN011010T1010
1SBN011010T1001
10
10
kg
0.011
0.011
Order code
Pkg
qty
Weight
(1 pce)
kg
Front-mounted electronic timer
1SBC574001F0301
TEF3-ON
RV5
Rated control circuit
voltage - Uc
V
Type
ON-delay
NS, NSL
24...240 V AC/DC
TEF3-ON
1SBN021012R1000
1
0.065
OFF-delay
NS, NSL
24...240 V AC/DC
TEF3-OFF
1SBN021014R1000
1
0.065
Type
Order code
Pkg
qty
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
Weight
(1 pce)
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
4
Surge suppressors
For contactor relays
NS,
NSL
NS
NSL
Rated control circuit
voltage - Uc
V
AC
●
24...50
●
50...133
●
110...250
●
250...440
●
24...50
●
50...133
●
110...250
●
250...440
12...32
–
25...65
–
50...90
–
77...150
–
150...264
–
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
1SBC101298S0201
1SBC101337F0014
For contactors
ABB | 4/65
NS and NSL contactor relays
Technical data
Contact utilization characteristics according to IEC
Contactor relay types
AC operated
DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
4
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
NS
NSL
IEC 60947-5-1 and EN 60947-5-1
690 V
50 / 60 Hz
10 A
6 A
4 A
3 A
2 A
2 A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
Short-circuit protection device for contactors
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
10 A
100 A
140 A
12 V / 3 mA
10-7
1.5 ms
0.1 W
AC-15 1200 cycles/h
DC-13 900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux. contact blocks) are mechanically linked contacts.
for 1.0 s
for 0.1 s
Contact utilization characteristics according to UL / CSA
Contactor relay types
NS
NSL
UL 508, CSA C22.2 N°14
600 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
1SBC101502S0201
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
AC operated
DC operated
4/66 | ABB
NS and NSL contactor relays
Technical data
Magnet system characteristics for NS contactor relays
Contactor relay types
Coil operating limits
AC operated
NS
AC supply
acc. to IEC 60947-5-1
AC control voltage Rated control circuit voltage Uc
at 50 Hz
at 60 Hz
Coil consumption Average pull-in value 50 Hz
60 Hz
50/60 Hz
Average holding value 50 Hz
60 Hz
50/60 Hz
Drop-out voltage
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
24...415 V
24...415 V
33 VA
33 VA
33 VA
6.5 VA / 1.5 W
5 VA / 1.2 W
6.5 VA / 1.5 W
Approx. 30...50 % of Uc
4
9...24 ms
6...18 ms
5...19 ms
7...22 ms
(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.
Magnet system characteristics for NSL contactor relays
Contactor relay types
Coil operating limits
acc. to IEC 60947-5-1
DC control voltage
Drop-out voltage
Coil time constant
DC operated
DC supply
NSL
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
Rated control circuit voltage Uc
12...240 V DC
Average pull-in value 3 W
Coil consumption
Average holding value 3 W
Approx. 10...40 % of Uc
L/R 12 ms
Open
L/R 40 ms
Closed
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
36...59 ms
31...53 ms
13...17 ms
15...20 ms
(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2.
Mounting characteristics and conditions for use
Contactor relay types
AC operated
DC operated
NS
NSL
Mounting positions
Pos. 2
Pos. 4
Pos. 3
Pos. 1
The contactor relays can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101502S0201
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 5
ABB | 4/67
NS and NSL contactor relays
Technical data
General technical data
Contactor relay types
AC operated
DC operated
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
A
C1
B1
A
B2
C2
690 V
600 V
6 kV
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
Shock direction
A
B1
B2
C1
C2
Vibration withstand acc. to IEC 60068-2-6
20 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
NS contactor relays - AC operated
NSL contactor relays - DC operated
20 g
20 g closed position / 10 g open position
5 g
15 g closed position / 5 g open position
15 g
10 g
19 g closed position / 8 g open position
19 g closed position / 8 g open position
16 g closed position / 13 g open position
14 g closed position / 8 g open position
5...300 Hz / 3 g closed position / 2 g open position
Connecting characteristics
Contactor relay types
AC operated
DC operated
NS
NSL
Main terminals
Screw terminals with cable clamp
Connection capacity (min. ... max.)
Pole and coil terminals
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Recommended
Max.
Degree of protection
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
7.7 mm
3.2 mm
AWG 18...14
9 mm
1.00 Nm / 9 lb.in
1.20 Nm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All terminals
Screw terminals
All terminals
IP20
Delivered in open position, screws of unused terminals must be tightened
Screwdriver type
M3
Flat Ø 5.5 / Pozidriv 2
1SBC101502S0201
4
Rated insulation voltage Ui
acc. to IEC 60947-5-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor relay
Operation in free air
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
NS
NSL
4/68 | ABB
Notes
N16
4
ABB | 4/69
NS contactor relays
Terminal marking and positioning
NS contactor relays - AC operated
Standard devices without addition of auxiliary contact blocks
13 21 31 43
13 21 33 43
A1
NO NC NC NO
13 23 33 43
A1
NO NC NO NO
13 23 33 43
A1
NO NO NO NO
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
NO NO NO NO
51 61 71 81
NS22E
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
NS31E
NC NC NC NC
52 62 72 82
NO NC NC NO
14 22 32 44
14 22 34 44
A2
NS22E
NO NO NO NO
14 24 34 44
A2
NS31E
13 23 33 43
14 24 34 44
A2
NS40E
13 23 33 43
A1
NO NO NO NO
13 23 33 43
A1
NS44E
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
53 61 71 81
53 61 71 83
53 61 73 83
53 63 73 83
NO NC NC NC
NO NC NC NO
NO NC NO NO
NO NO NO NO
54 62 72 82
54 62 72 84
54 62 74 84
54 64 74 84
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
14 24 34 44
14 24 34 44
A2
NS53E
14 24 34 44
A2
NS62E
14 24 34 44
A2
NS71E
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
NS40E
13 23 33 43
A1
A1
A2
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
NS44E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
NS53E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
A2
NS80E
NS62E
NS71E
NS80E
Other possible contact combinations with auxiliary contact blocks added by the user
13 21 33 43
13 21 33 43
A1
NO NC NO NO
13 23 33 43
A1
NO NC NO NO
53
5-
=
NO
54
+
5-
NO NC NO NO
14 22 34 44
Combination 41E
13 23 33 43
14 22 34 44
=
51
61
NO
NC
NC
-4
52
62
14 24 34 44
A2
+
CA3-10
NO NO NO NO
53
=
NO
54
+
5-
NO NO NO NO
-3
53
63
NO
NO
NO
-4
54
64
NO NO NO NO
14 24 34 44
A2
Combination 50E
=
14 24 34 44
NS40E
+
CA3-10
CA3 1-pole auxiliary contact blocks
NO
-1
NO
NC
-4
=
CA3-10
4/70 | ABB
13
NO
21
NC
33
NO
43
NO
53
NO
A2
NO
14
NC
22
NO
34
NO
44
NO
54
+
NC
NC
Combination 41E
-2
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
A2
+
13 23 33 43
A1
CA3-01 +
CA3-01
A1
Combination 42E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO NO NO NO
5-
6-
5-
6-
-3
=
+
-3
+
NO
-4
NO
14 24 34 44
A2
Combination 60E
=
NS40E
Combination 50E
-4
NO NO NO NO
56
NC
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
A2
+
CA3-10 +
CA3-10
Combination 60E
67
68
NO
55
NC
67
NO
NC
56
NO
68
NC
-2
CA3-01
-1
-2
NS40E
-2
-4
6-
14 24 34 44
A2
55
-3
A1
TEF3 front-mounted electronic timer
-1
-3
5-
-1
NO NO NO NO
NO NO NO NO
A2
6-
+
NO NO NO NO
5-
5-
=
Combination 42E
13 23 33 43
A1
A1
NO NO NO NO
NO NO NO NO
NS31E
13 23 33 43
A1
NO NO NO NO
14 24 34 44
-3
NO NC NO NO
A2
13 23 33 43
A1
NO NO NO NO
TEF3
1SBC101410S0201
4
NO NC NO NO
NSL contactor relays
Terminal marking and positioning
NSL contactor relays - DC operated (the polarity A1+, A2- must be respected)
Standard devices without addition of auxiliary contact blocks
A1+
13 21 31 43
13 21 33 43
A1+
NO NC NC NO
13 23 33 43
A1+
NO NC NO NO
13 23 33 43
A1+
NO NO NO NO
A1+
NO NO NO NO
A2-
51 61 71 81
13
NO
21
NC
31
NC
43
NO
NO
14
NC
22
NC
32
NO
44
A1+
A2-
NSL22E
13
NO
21
NC
33
NO
43
NO
NO
14
NC
22
NO
34
NO
44
NSL31E
NC NC NC NC
52 62 72 82
NO NC NC NO
14 22 32 44
NO NC NO NO
14 22 34 44
A2-
NO NO NO NO
14 24 34 44
A2-
A1+
NO NO NO NO
14 24 34 44
A2-
A2A2-
NSL22E
NSL31E
13 23 33 43
NSL40E
13 23 33 43
A1+
NSL44E
13 23 33 43
A1+
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
53 61 71 81
53 61 71 83
53 61 73 83
53 63 73 83
NO NC NC NC
NO NC NC NO
NO NC NO NO
NO NO NO NO
54 62 72 82
54 62 72 84
54 62 74 84
54 64 74 84
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
14 24 34 44
14 24 34 44
A2-
NSL53E
14 24 34 44
A2-
NSL62E
14 24 34 44
A2-
NSL71E
23
NO
33
NO
43
NO
NO
14
NO
24
NO
34
NO
44
NSL40E
13 23 33 43
A1+
13
NO
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
NSL80E
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
4
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
NSL62E
NSL53E
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A2-
13
NO
NSL44E
A1+
A1+
A1+
NSL71E
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
NSL80E
Other possible contact combinations with auxiliary contact blocks added by the user
13 21 33 43
A1+
NO NC NO NO
13 23 33 43
A1+
NO NC NO NO
53
5-
=
NO
54
+
5-
NO NC NO NO
14 22 34 44
-3
51
61
NO
NC
NC
-4
52
62
NO NC NO NO
14 22 34 44
A2-
13 23 33 43
A1+
NO NO NO NO
14 24 34 44
5-
6-
5-
6-
-1
=
NO NO NO NO
A2-
A1+
NO NO NO NO
+
-1
+
NC
-2
NC
14 24 34 44
13
NO
21
NC
33
NO
43
NO
53
NO
A2-
NO
14
NC
22
NO
34
NO
44
NO
54
Combination 41E
-2
A1+
NO NO NO NO
A2-
A1+
A2A2-
Combination 41E
13 23 33 43
=
NSL31E
13 23 33 43
A1+
NO NO NO NO
+
=
54
+
5-
NO NO NO NO
-3
53
63
NO
NO
NO
-4
54
64
NO NO NO NO
14 24 34 44
A2-
Combination 50E
=
=
14 24 34 44
NSL40E
+
CA3-10
CA3 1-pole auxiliary contact blocks
-3
NO
-1
NO
NC
-4
CA3-10
CA3-01
6-
5-
6-
-3
-3
+
NO
-4
NO
14 24 34 44
A2-
Combination 60E
=
NSL40E
33
NO
43
NO
51
NC
61
NC
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
Combination 50E
-4
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
A2-
+
23
NO
Combination 42E
NO NO NO NO
CA3-10 +
CA3-10
Combination 60E
TEF3 front-mounted electronic timer
56
NC
67
68
NO
55
NC
67
NO
NC
56
NO
68
NC
-2
CA3-01
5-
+
-2
-4
CA3-01 +
A1+
=
55
-1
-3
+
NO NO NO NO
NO NO NO NO
A2-
NSL40E
13 23 33 43
A1+
NO NO NO NO
5-
NO
Combination 42E
13 23 33 43
A1+
NO NO NO NO
53
14 24 34 44
CA3-10
13
NO
1SBC101410S0201
13 21 33 43
TEF3
ABB | 4/71
NS contactor relays
Main dimensions mm, inches
4-pole contactor relays
72.5 2.85"
ø 4.2 0.17"
50 1.97"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
68 2.68"
35 1.38"
2x
M4 8-32 UNC
7 0.28"
45 1.77"
4
NS22E, NS31E, NS40E
100.2 3.94"
72.5 2.85"
2x
M4 8-32 UNC
5.5 0.22"
60 2.36"
44.2 1.74"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
35 1.38"
ø 4.2 0.17"
50 1.97"
45 1.77"
NS22E, NS31E, NS40E
+ CA3 front-mounted 1-pole auxiliary contact block
128.1 5.04"
72.5 2.85"
45 1.77"
10
0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
50 1.97"
60 2.36"
5.5 0.22"
44.4 1.75"
1.1 0.05"
44.2 1.74"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
NS22E, NS31E, NS40E
+ TEF3 electronic timer
8-pole contactor relays
100.2 3.94"
72.5 2.85"
35 1.38"
ø 4.2 0.17"
50 1.97"
44.2 1.74"
5.5 0.22"
60 2.36"
2x
M4 8-32 UNC
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
1SBC101411S0201
NS44E, NS53E, NS62E, NS71E, NS80E
4/72 | ABB
NSL contactor relays
Main dimensions mm, inches
4-pole contactor relays
72.5 2.85"
35 mm EN/IEC 60715
5.5 0.22"
ø 4.2 0.17"
60 2.36"
68 2.68"
35 1.38"
2x
M4 8-32 UNC
7 0.28"
45 1.77"
4
NSL22E, NSL31E, NSL40E
100.2 3.94"
72.5 2.85"
45 1.77"
2x
M4 8-32 UNC
5.5 0.22"
35 1.38"
ø 4.2 0.17"
60 2.36"
44.2 1.74"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
NSL22E, NSL31E, NSL40E
+ CA3 front-mounted 1-pole auxiliary contact block
128.1 5.04"
72.5 2.85"
45 1.77"
10
0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
50 1.97"
60 2.36"
5.5 0.22"
44.4 1.75"
1.1 0.05"
44.2 1.74"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
NSL22E, NSL31E, NSL40E
+ TEF3 electronic timer
8-pole contactor relays
100.2 3.94"
72.5 2.85"
44.2 1.74"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
60 2.36"
2x
M4 8-32 UNC
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
1SBC101411S0201
NSL44E, NSL53E, NSL62E, NSL71E, NSL80E
ABB | 4/73
Auxiliary contact blocks
Accessories
1SBC101036F0014
Description
CA3-10
4
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.
CA3 1-pole auxiliary contact blocks, designed for standard industrial environments, are equipped with:
– – N.O. or N.C. contacts.
– – Screw-type connecting terminals with cage clamp delivered open.
All 1-pole auxiliary contact blocks are protected against accidental direct contact and bear the
corresponding function marking.
A maximum of two 1-pole auxiliary contact blocks can be front-mounted on 1-stack contactors or 1-stack
contactor relays.
Ordering details
For contactors
For contactor relays
Contact Type
blocks
Order code
Pkg
qty
Weight
(1 pce)
kg
1-pole auxiliary contact blocks with screw terminals
AS09 ... AS16
NS, NSL
1 – CA3-10
ASL09 ... ASL16
– 1 CA3-01
Main dimensions
1SBN011010T1010
1SBN011010T1001
10
10
0.011
0.011
mm, inches
100.2 3.94"
4/74 | ABB
5.5 0.22"
10
0.39"
1SBC101492S0201
35 mm EN/IEC 60715
68 2.68"
7 0.28"
44.2 1.74"
72.5 2.85"
45 1.77"
Auxiliary contact blocks
Technical data
Contact utilization characteristics according to IEC
1-pole CA3
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
690 V
10 A
Types
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity
Breaking capacity
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
Mechanically linked contacts acc. to annex L of IEC 60947-5-1
Mirror contacts acc. to annex F of IEC 60947-4-1
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
for 1.0 s
for 0.1 s
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
10 A
100 A
140 A
12 V / 3 mA
10-7
0.1 W
4
10 millions operating cycles
3600 cycles/h
AC-15 1200 cycles/h
DC-13 900 cycles/h
Additional N.O. or N.C. auxiliary contacts (CA3) are mechanically linked contacts
Additional N.C. auxiliary contacts (CA3) are mirror contacts
Contact utilization characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
690 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Connecting characteristics
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
Connection capacity acc. to UL / CSA
Stripping length
Recommended
Tightening torque
Max.
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
7.7 mm
3.2 mm
AWG 18...14
9 mm
1 Nm / 9 Ib.in
1.20 Nm
IP20
Delivered in open position, screws of unused terminals must be tightened
M3
Flat Ø 5.5 / Pozidriv 2
1SBC101493S0201
Connection capacity (min. ... max.)
Rigid solid
ABB | 4/75
Auxiliary contact blocks for AS09 ... AS16, ASL09 ... ASL16
contactors and NS, NSL contactor relays
Electrical durability
Electrical durability for AC-15 utilization category - Ue ≤ 400 V
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
This curve represents the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.
Millions of
operating
cycles
30
20
10
5
3
2
1
0.5
0.3
0.2
1
0.1
0.02
0.05
0.1
0.2
0.3
0.5
1
3
1.3
5
7
9
2
3
4
5
6
10
Breaking current Ic (A)
Example:
Breaking current = 1.3 A
On the opposite curve at intersection " " 1.3 A the corresponding value for the electrical durability is approximately 2 millions
operating cycles.
1SBC101932S0201
4
The curve has been drawn for resistive and inductive loads up to 400 V:
– – AS09 ... AS16 and ASL09 ... ASL16 contactor built-in auxiliary contacts
–– 1-pole CA3
–– NS and NSL contactor relays.
4/76 | ABB
Electronic timers
4
Ordering details
For contactors, Time delay
contactor relays range
Delay
type
selected by
switch
Rated control
circuit voltage
Uc
Auxiliary Type
contacts
Order code
24...240
1
1
TEF3-ON
1SBN021012R1000
kg
0.065
OFF-delay 24...240
1
1
TEF3-OFF
1SBN021014R1000
0.065
V 50/60 Hz or DC
TEF3-OFF
AS09 ... AS16
ASL09 ... ASL16
NS, NSL
0.1...1 s
1...10 s
10...100 s
Main dimensions
Weight
Pkg
(1 pce)
ON-delay
mm, inches
128.1 5.04"
72.5 2.85"
10
0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
1.1 0.05"
1SBC101504S0201
5.5 0.22"
50 1.97"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
60 2.36"
45 1.77"
44.4 1.75"
1SBC101336F0010
TEF3-ON
TEF3 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFFdelay versions.
Compact solution in cabinet compared to separate timers
TEF3 electronic timers are front-mounted and locked on AS/ASL contactors or NS/NSL contactor relays.
A mechanical indicator allows to show the state of the contactor.
Safe and cost-reduced wiring
TEF3 electronic timers are supplied by a direct plug-in parallel connection to the coil terminals A1 - A2 of
the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against
surges in the contactor coil.
Available for a wide control voltage range 24...240 V AC/DC
TEF3-ON or TEF3-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently
of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted
by means of a rotary switch. The timing function is activated by closing or opening the device on which the
timer is mounted. The OFF-delay version operates without additional control supply.
44.2 1.74"
1SBC101337F0010
Description
ABB | 4/77
Electronic timers
Technical data
Contact utilization characteristics according to IEC
Types
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
TEF3-OFF
3 A
1.5 A
10 x Ie AC-15
10 x Ie AC-15
1 A / 24 W
6 A
for 1.0 s 8 A
for 0.1 s 8 A
12 V / 3 mA
24 V DC 10-7
0.1 W
ON-delay
24 V DC
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 3 A
Function diagram
OFF-delay
150 ms
min.
Uc (A1 - A2)
1s
min.
Uc (A1 - A2)
100 ms
min.
100 ms
min.
N.O. (67 - 68)
N.O. (67 - 68)
N.C. (55 - 56)
N.C. (55 - 56)
t
t
Bistable relay inside.
Before use, once apply Uc then switch it off in order to initialize position of the contacts.
Control circuit voltage
AC control voltage
50/60 Hz
DC control voltage
Rated control circuit voltage Uc
Average consumption
Rated control circuit voltage Uc
Average consumption
Rated frequency limits
Supply voltage range
Overvoltage protection
Time delay range (t) selected by switch
24...240 V AC
1.5 mA RMS
24...240 V DC
1.5 mA
50 / 60 Hz
0.85...1.1 x Uc (at θ ≤ 70 °C)
Varistor included
1 mA RMS
1 mA
0.1...1 s
1...10 s
10...100 s
On-load reiteration accuracy under constant conditions
Minimum ON period
Recovery time
Ambient air temperature Operation
Storage
Climatic withstand
Maximum operating altitude
Mounting positions
Shock withstand
≤1%
0.1 s
1 s
0.15 s
0.1 s
-25 °C ... +70 °C
-40 °C ... +80 °C
Category B according to IEC 60947-1 Annex Q
2000 m
Mounting positions 1, 1 +/- 30°, 2, 3, 4, 5
1/2 sinusoidal shock for 11 ms: no change in contact position
Same as contactor or contactor relay
acc. to IEC 60068-2-27 and EN 60068-2-27
(Mounting position 1)
Vibration withstand
5...300 Hz
3 g closed position / 2 g open position
acc. to IEC 60068-2-6
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
5 millions operating cycles
3600 cycles/h
AC-15
DC-13
4/78 | ABB
1200 cycles/h
900 cycles/h
1800 cycles/h
1SBC101505S0201 - Rev. A
4
TEF3-ON
IEC 60947-5-1 and EN 60947-5-1
400 V
4 kV
240 V
50 / 60 Hz
5 A
Electronic timers
Technical data
Contact utilization characteristics according to UL / CSA
Types
Standards
Rated insulation voltage Ui acc. to UL / CSA
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
TEF3-ON
UL 508, CSA C22.2 N°14
300 V
240 V
B300, R300
5A
3600 VA
360 VA
1A
28 VA
TEF3-OFF
4
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Recommended
Max.
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
7.7 mm
3.2 mm
AWG 18...14
9 mm
1 N.m / 9 lb.in
1.20 N.m
Degree of protection
Screw terminals
All terminals
Screwdriver type
Terminal Marking
IP20
Delivered in open position, screws of unused terminals should be tightened
M3
Flat Ø 5.5 / Pozidriv 2
A1
55 NC
67 NO
KM1
A2
A1
55 NC
67 NO
56 NC
68 NO
KM1
56 NC
68 NO
A2
1SBC101505S0201 - Rev. A
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
ABB | 4/79
Surge suppressors for contactor coils
Description
(V)
1000
T (µs)
0
1000
0
100
4
100
The operation of inductive circuits causes overvoltages, in particular on opening the contactor coil.
The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form
of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are
observed ranging from interference on the electronic devices to the breakdown of insulators and even the
destruction of certain sensitive components.
The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz
coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.
Following a burst of discharges with a very steep slope, a damped oscillation emerges with a peak value
of 3500 V.
Overvoltage Factor
The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak
value Ûc of the coil rated control voltage Uc:
1SBC101042F0014
RC5-1
k =
For example the following is obtained for the above graph:
3500
≈ 60
42 √2
To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppressors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping
voltage frequencies.
Each case is different, but the technical data tolerances and generous sizing of parts have enabled us to
reduce the number of variants.
We have chosen the following solutions: transil diodes, varistors and RC blocks.
Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.
Ordering details
For
contactors
For
contactor
relays
AS, ASL
NS, NSL
AS
NS
ASL
NSL
Rated control circuit
voltage - Uc
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
RT5
Main dimensions
AC
●
●
●
●
●
●
●
●
–
–
–
–
–
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
Type
Order code
Pkg
qty
Weight
(1 pce)
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
mm, inches
45 1.77"
45 1.77"
68 2.68"
72.5 2.85"
4/80 | ABB
Ûs max.
in AC k =
Uc √2
Easy connection to the coil terminals
(parallel mounting)
Clip-on for both fixing and connection.
No additional space
Clipped onto the right side part of
the contactor base without changing
contactor overall dimensions and
keeping a free access to coil terminals.
1SBC101494S0201
1SBC101042F0014
RV5
Ûs max.
in DC k =
Uc
68 2.68"
1SBC101042F0014
Ûs max.
k =
Ûc
Surge suppressors for contactor coils
Technical data
Varistor
RV5/50
RV5/133
RV5/250
RV5/440
24...50 V AC
50...133 V AC
110...250 V AC
250...440 V AC
24...50 V DC
50...133 V DC
110...250 V DC
250...440 V DC
132 V AC
270 V AC
480 V AC
825 V AC
132 V DC
270 V DC
480 V DC
825 V DC
none
-20...+70 °C
High energy absorption: good damping - Unpolarized system
Clipping as from Uvdr*, thus voltage front up to this point
*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10 %
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Advantages
Drawback
4
RC type
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
24...50 V AC
50...133 V AC
110...250 V AC
250...440 V AC
2 to 3 x Uc max.
2...3
-20...+70 °C
Very fast clipping - Attenuation of steep fronts and thus of high frequencies
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Advantages
Transil diode
RT5/32
RT5/65
RT5/90
RT5/150
12...32 V DC
25...65 V DC
50...90 V DC
77...150 V DC
50 V DC
100 V DC
150 V DC
210 V DC
1.1...1.2
-20...+70 °C
Good energy absorption - Unpolarized system - Simple, reliable system
Delay on drop out which does not however reduce contactor breaking capacity
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Advantages
Drawback
RT5/264
150...264 V DC
390 V DC
Wiring diagrams
RC type
E0734D
A2
A2
Transil diode
1SBC101602S0201
Varistor
E0735D
A2
A1
A1
E0733D
A1
ABB | 4/81
Mechanical interlock unit and other accessories
Mechanical interlock unit
When mounted between two contactors without additional width, the VM3 mechanical interlock unit prevents one of the contactors from closing as long as the other contactor is closed.
The mechanical interlock unit includes 2 fixing clips.
VM3
Ordering details
For contactors
Left
AS
ASL
4
Right
AS
ASL
Type
Order code
Pkg
qty
Weight
(1 pce)
VM3
1SBN031005T1000
10
0.002
Weight
(1 pce)
kg
Note : VM3 mechanical durability, 5 millions of operating cycles on both reversing contactors.
Fixing clips
BB3 is a set of 50 fixing clips.
Ordering details
For contactors
Type
Order code
Pkg
qty
AS, ASL
BB3
1SBN111020R1000
1
0.009
kg
Test block
BDT4 test block is suitable for switching on contactor off-load.
Marking on the block indicates the contactor type to fit with.
BB3
1SBC100043V0014
Ordering details
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
AS, ASL, NS, NSL
BDT4
1SBN110122T1000
10
kg
0.007
Function markers
Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500
marking table to identify your contactors, overload relays or manual motor starters.
Marker dimensions: 7 x 20 mm (.276" x .787").
BDT4
1SNC160101F0014
Ordering details
For contactors
Type
Order code
Pkg
qty
AS, ASL, NS, NSL
AMS 500 support plate for 8 BA4
HTP500 support plate
BA4
SPRC 1
HTP500-BA4
1SNA235156R2700
1SNA360010R1500
1SNA235712R2400
16
1
1
Weight
(1 pce)
kg
0.011
0.220
0.290
1SBC101496S0201 - Rev. A
BA4
4/82 | ABB
Connection accessories for starting solutions
1SBC101034F0014
Connecting links
The BEA16-3 insulated 3-pole connecting links are used to connect an AC or DC operated contactors with
manual motor starters.
The connecting links ensure the electrical and mechanical connection between the contactor and the
manual motor starter.
Ordering details
BEA16-3
For contactors
Manual motor
starter
Type
AS09 ... AS16
ASL09 ... ASL16
MS116-0.16 ... MS116-16 BEA16-3
MS132-0.16 ... MS132-16
Order code
Pkg
qty
1SBN081006T1000
10
Weight
(1 pce)
kg
0.019
4
Connection sets for reversing contactors
1SBC101071F0014
The BER16C-3 connection sets are used for the connections between the main poles of two 3-pole
contactors mounted side by side as reversing contactors, including electrical interlocking between built-in
N.C. auxiliary contact and coil terminals.
The connection sets are made up of:
– – 1 upstream and 1 downstream connections: insulated, solid copper bars,
– – 2 connections to realize electrical interlocking between contactors equipped with built-in N.C. auxiliary
contacts,
– – 2 fixing clips.
BER16C-3
Ordering details
For contactors
Mechanical
interlock unit
Type
Order code
Pkg
qty
2 x AS09 … AS16
2 x ASL09 … ASL16
with or without VM3
BER16C-3
1SBN081012R1000
1
Weight
(1 pce)
kg
0.035
BEY16C-3
BEY16C-3 connection sets are designed for star-delta starters whose contactors are assembled according
to line delta star mounting.
The connection sets are made up of:
– – L ine contactor / delta contactor: upstream phase-to-phase connection,
– – D elta contactor / star contactor: downstream connection in parallel,
– – Star contactor: star point upstream,
– – A n electrical interlocking between delta and star contactors equipped with built-in N.C. auxiliary contacts,
– – 4 fixing clips.
Ordering details
For contactors
Line
AS09
AS12
Delta
AS09
AS12
Star
AS09
AS09
Mech. interlock unit
between star & delta
contactors
with or without VM3
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
BEY16C-3
1SBN081018R2000
1
0.041
1SBC101495S0201
1SBC101070F0014
Connection sets for star-delta starting
ABB | 4/83
Voltage code table
The below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please
give either type or order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the
type or in the order code according to the table below. Example: for contactor AS09-30-10 and coil 42 V 50/60 Hz, type is
AS09-30-10-21 and order code is 1SBL101001R2110.
3-pole contactors
Auxiliary contacts
N.O. N.C.
Type
AS16 - 30 - 10 - 26
1SBL121001R 26 10
N.O. N.C.
Main contacts
Contactor type
AS AC operated
ASL DC operated
80
81
83
84
86
87
88
89
DC coil code
12 V
24 V
48 V
60 V
110 V
125 V
220 V
240 V
80
81
83
84
86
87
88
89
DC coil code
12 V (1)
24 V
48 V
60 V
110 V
125 V
220 V
240 V
3-pole reversing contactors
Type
Order code
VAS12
S
EM - 26
M
1SBK113800M 26 00
Surge suppressor
VAS
VASL
Contactor type
AC operated
DC operated
Contactor relays
Type
NS 40 E - 26
N.O. N.C.
Number contacts
Contactor type
NS AC operated
NSL DC operated
4/84 | ABB
Order code
1SBH101001R 26 40
AC coil code
50 Hz
60 Hz
20 24 V
24 V
21 42 V
42 V
22 48 V
48 V
23 110 V
110 V
24 115 V
115 V
16 –
120 V
25 220 V
220 V
26 230 V
230 V
27 240 V
240 V
17 –
277 V
13 380 V
–
28 400 V
400 V
29 415 V
415 V
AC coil code
50 Hz
60 Hz
20 24 V
24 V
21 42 V
42 V
22 48 V
48 V
23 110 V
110 V
24 115 V
115 V
16 –
120 V
25 220 V
220 V
26 230 V
230 V
27 240 V
240 V
17 –
277 V
13 380 V
–
28 400 V
400 V
29 415 V
415 V
(1) Not for VASL..SEM
80
81
83
84
86
87
88
89
DC coil code
12 V
24 V
48 V
60 V
110 V
125 V
220 V
240 V
1SBC101600S0201
4
Order code
AC coil code
50 Hz
60 Hz
20 24 V
24 V
21 42 V
42 V
22 48 V
48 V
23 110 V
110 V
24 115 V
115 V
16 –
120 V
25 220 V
220 V
26 230 V
230 V
27 240 V
240 V
17 –
277 V
13 380 V
–
28 400 V
400 V
29 415 V
415 V
Notes
N17
4
ABB | 4/85
Summary_5
5
5/0 | ABB
AF, EK contactors and NF contactor relays
Motor starting solution, in kit form
DOL and reversing starters protected by manual motor starters
5/4
DOL starters protected by moulded-case circuit-breakers
5/16
DOL and reversing starters protected by overload relays
5/32
Star-delta starters protected by overload relays
5/56
AF 3-pole contactors
Contents
5/79
Overview 3-pole contactors
5/80
Ordering details 3-pole contactors
5/82
Technical data 3-pole contactors
5/120
Terminal marking and positioning
5/141
Main dimensions
5/144
5
AF and EK 4-pole contactors
Contents
5/179
Overview 4-pole contactors
5/180
Ordering details 4-pole contactors
5/182
Technical data 4-pole contactors
5/206
Terminal marking and positioning
5/216
Main dimensions
5/220
Contactors for DC switching
General description
5/235
AF and EK selection table for DC switching
5/238
Ordering details GA75 ... GAF2050
5/242
Technical data
5/248
Terminal marking and positioning
5/255
Main dimensions
5/256
Contactors for capacitor switching
Contents
5/263
Overview
5/264
UA16..RA up to UA110..RA - Unlimited peak Î
5/266
UA16 up to UA110 - Peak current Î ≤ 100 times the rms current
5/276
Other contactor application data
5/287
NF contactor relays
Contents
5/303
Ordering details
5/304
Technical data
5/312
Terminal marking and positioning
5/315
Main dimensions
5/317
Accessories
NF contactor relays
5/321
Accessories for UA, UA..RA, GA and GAF contactors
5/357
Accessories for EK550, EK1000 contactors
5/381
Voltage code table
5/392
Questionnaire for product specifications
5/396
ABB | 5/1
Summary_5
Accessories for AF09 ... AF2650 contactors and
Summary_5-1
5
5/2 | ABB
Motor starting solution, in kit form
DOL and reversing starters protected by manual motor starters
General
5/4
Selection tables
5/6
Wiring diagrams
5/10
Dimension drawings
5/11
DOL starters protected by moulded-case circuit-breakers and
overload relays
General
5/16
Selection tables
5/18
Wiring diagrams
5/22
5
Dimension drawings, starter protected by
MCCB including motor protection
5/23
MCCB (magnetic only) and thermal overload relays
5/25
DOL and reversing starters protected by overload relays
General
5/32
Selection tables
5/34
Switching frequency diagrams for overload relays
5/38
Wiring diagrams
5/39
Dimension drawings, starter protected by
Thermal overload relays
5/40
Electronic overload relays
5/46
Star-delta starters protected by overload relays
General
5/56
Selection tables
5/58
Switching frequency diagrams for overload relays
5/62
Wiring diagrams
5/63
Dimension drawings, starter protected by
5/65
Electronic overload relays
5/70
Summary_5-1
Thermal overload relays
ABB | 5/3
DOL and reversing starters protected by manual motor starters
With AF contactors - open type version in kit form
Application
I>
Full voltage direct-on-line (DOL) starting and reversing starting for controlling three-phase asynchronous
motors is a simple and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed
torque) and a starting current 5.5 to 7 times nominal current.
I/In C/Cn
7
6
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
2
1SFC101102V0001
5
C
1
0
DOL starter
MS132-10 + BEA16-4 + AF09-30-10
10
30
60
80
100
Coordination types
The contactor and the manual motor starter control and protect motors against overload and short-circuits
according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1) defining the anticipated level of
service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts light welding is acceptable.
I>
Main Technical Data
1SFC101105V0001
Standards
Rated operational voltage Ue max.
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Switching frequency
Ambient air temperature
Close to the device
use with MS116
use with MS132,
MS450, MS495
Degree of protection
IEC 60947-4-1 / EN 60947-4-1
690 V - 50/60 Hz
690 V
600 V
≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time
≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting time
≤ 55 °C
≤ 60 °C
IP20
Reversing starter
MS132-10 + BEA16-4 + BER16-4
+ VEM4 + AF09-30-10
Mounting positions
+30°
-30°
-30°
Pos. 4
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
DOL starters
Pos. 1
Pos. 1 ± 30°
Pos. 5
Reversing starters
1SBC101917S0201
Pos. 3
5/4 | ABB
+30°
Pos. 2
Pos. 2
DOL and reversing starters protected by manual motor starters
With AF contactors - open type version in kit form
Direct-on-line starters
Description
I>
MS
Manual motor starter
You can easily assemble a direct-on-line starter by using the BEA..-4
connecting link 3-pole insulated. It is used to electrically and mechanically connect MS116 or MS132 manual motor starter and
AF09 ... AF38 contactor, AC or DC operated.
BEA
Connecting link
5
AF09 ... AF38
Contactor
Reversing starters
Description
I>
MS
Manual motor starter
Fixing clip
BEA
Connecting link
You can easily assemble reversing starter thanks to our complete range
of accessories:
–– BEA..-4 connecting link 3-pole insulated: it is used to electrically and
mechanically connect MS116 or MS132 manual motor starter and
AF09 ... AF38 contactor, AC or DC operated
–– For AF09 ... AF38, use VEM4 mechanical and electrical interlock set
for reversing starter in 90 mm width. It includes:
-- VM4 mechanical interlock unit including 2 fixing clips
-- VE4 electrical interlock block with A2-A2 connection.
–– For AF40 ... AF96, use VM96-4 mechanical interlock unit and additional auxiliary contact blocks for electrical interlocking
–– BER..-4 connection set: it assures a safe and simple reversing connection between both contactor main terminals.
VM4
Mechanical
interlock unit
AF09 ... AF38
Contactor
VE4
Electrical
interlock block
A2
BER..-4
Connection set
Select now easily and quickly your starter in the following pages for coordination type 1 or 2 at 400 V, 50 / 60 Hz, Iq = 16 kA up to 18.5 kW
and Iq = 50 kA up to 45 kW.
For the full coordination tables:
www.abb.com/lowvoltage then go to the right menu: "Support", select: "Online Product Selection Tools" then select "Coordination Tables for motor protection"
ABB | 5/5
1SBC101917S0201
A2
DOL starters protected by MS manual motor starters
Coordination type 1
Coordination type 1, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz
Contactors
Accessories
I>
5
BEA..-4
Current
setting
range
Magnetic Rated control circuit
tripping voltage
current Uc min. ... Uc max.
1SAM350000R1002
A
0.16...0.25
A
2.44
MS132-0.4
1SAM350000R1003
0.25...0.40
3.9
0.44
MS132-0.63
1SAM350000R1004
0.40...0.63
6.14
0.18
0.6
MS132-0.63
1SAM350000R1004
0.40...0.63
6.14
0.25
0.85
MS132-1.0
1SAM350000R1005
0.63...1.00
11.5
0.37
1.1
MS132-1.6
1SAM350000R1006
1.00...1.60
18.4
0.55
1.5
MS132-1.6
1SAM350000R1006
1.00...1.60
18.4
0.75
1.9
MS132-2.5
1SAM350000R1007
1.60...2.50
28.75
1.1
2.7
MS132-4.0
1SAM350000R1008
2.50...4.00
50
1.5
3.6
MS132-4.0
1SAM350000R1008
2.50...4.00
50
2.2
4.9
MS132-6.3
1SAM350000R1009
4.00...6.30
78.75
3
6.5
MS132-10
1SAM350000R1010
6.30...10.0
150
4
8.5
MS132-10
1SAM350000R1010
6.30...10.0
150
5.5
11.5
MS132-12
1SAM350000R1012
8.00...12.0
180
7.5
15.5
MS132-16
1SAM350000R1011
10.0...16.0
240
11
22
MS132-25
1SAM350000R1014
20.0...25.0
375
IEC
Type
(1)
AC-3, 400 V
Rated
operational
power current
kW
A
0.06 0.2
MS132-0.25
0.09
0.3
0.12
Order code
Order code
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF12Z-30-10-21
AF12-30-10-13
AF16Z-30-10-21
AF16-30-10-13
AF26Z-30-00-21
AF26-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF38Z-30-00-21
AF38-30-00-13
AF52-30-00-11
AF52-30-00-13
AF65-30-00-11
AF65-30-00-13
AF80-30-00-11
AF80-30-00-13
AF80-30-00-11
AF80-30-00-13
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL156001R2110
1SBL157001R1310
1SBL176001R2110
1SBL177001R1310
1SBL236001R2100
1SBL237001R1300
1SBL276001R2100
1SBL277001R1300
1SBL296001R2100
1SBL297001R1300
1SBL367001R1100
1SBL367001R1300
1SBL387001R1100
1SBL387001R1300
1SBL397001R1100
1SBL397001R1300
1SBL397001R1100
1SBL397001R1300
(3)
(2)
15
29
MS132-32
1SAM350000R1015
25.0...32.0
480
18.5
35
MS450-40
1SAM450000R1005
28.0…40.0
520
22
41
MS450-50
1SAM450000R1007
36.0…50.0
650
30
55
MS495-63
1SAM550000R1007
45.0…63.0
819
37
66
MS495-75
1SAM550000R1008
57.0…75.0
975
45
80
MS495-90
1SAM550000R1009
70.0…90.0
1170
(1)
(2)
(3)
Type
V 50/60 Hz
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24…60
100...250
24…60
100...250
24…60
100...250
24…60
100...250
24…60
100...250
V DC
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20…60
100...250
20…60
100...250
20…60
100...250
20…60
100...250
20…60
100...250
MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 15 kW, 400 V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
For other control voltages, see "Voltage code table".
AF40 3-pole contactor can be selected for coordination type 1, 16 kA and 50 kA, 18.5 kW, 400 V - AC-3.
5/6 | ABB
Allowed Type
setting
current
A
0.25
CA4-10
Order code
BEA16-4
1SBN081306T1000
BEA38-4
CA4-10
1SBN082306T2000
1SBN010110R1010
CA4-10
1SBN010110R1010
0.4
0.63
0.63
1
1.6
1.6
2.5
4
4
6.3
9
9
12
16
25
+
32
38
50
63
75
80
1SBC101913S0201 - Rev. A
Manual motor starters
DOL starters protected by MS manual motor starters
Coordination type 2
Coordination type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
Accessories
I>
BEA..-4
Current
setting
range
Magnetic Rated control circuit
tripping voltage
current Uc min. ... Uc max.
1SAM350000R1002
A
0.16...0.25
A
2.44
MS132-0.4
1SAM350000R1003
0.25...0.40
3.9
0.44
MS132-0.63
1SAM350000R1004
0.40...0.63
6.14
0.18
0.6
MS132-0.63
1SAM350000R1004
0.40...0.63
6.14
0.25
0.85
MS132-1.0
1SAM350000R1005
0.63...1.00
11.5
0.37
1.1
MS132-1.6
1SAM350000R1006
1.00...1.60
18.4
0.55
1.5
MS132-1.6
1SAM350000R1006
1.00...1.60
18.4
0.75
1.9
MS132-2.5
1SAM350000R1007
1.60...2.50
28.75
1.1
2.7
MS132-4.0
1SAM350000R1008
2.50...4.00
50
IEC
Type
(1)
AC-3, 400 V
Rated
operational
power current
kW
A
0.06 0.2
MS132-0.25
0.09
0.3
0.12
Order code
Type
Order code
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF38Z-30-00-21
AF38-30-00-13
AF52-30-00-11
AF52-30-00-13
AF65-30-00-11
AF65-30-00-13
AF80-30-00-11
AF80-30-00-13
AF96-30-00-11
AF96-30-00-13
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL276001R2100
1SBL277001R1300
1SBL276001R2100
1SBL277001R1300
1SBL276001R2100
1SBL277001R1300
1SBL296001R2100
1SBL297001R1300
1SBL367001R1100
1SBL367001R1300
1SBL387001R1100
1SBL387001R1300
1SBL397001R1100
1SBL397001R1300
1SBL407001R1100
1SBL407001R1300
(3)
(2)
1.5
3.6
MS132-4.0
1SAM350000R1008
2.50...4.00
50
2.2
4.9
MS132-6.3
1SAM350000R1009
4.00...6.30
78.75
3
6.5
MS132-10
1SAM350000R1010
6.30...10.0
150
4
8.5
MS132-10
1SAM350000R1010
6.30...10.0
150
5.5
11.5
MS132-12
1SAM350000R1012
8.00...12.0
180
7.5
15.5
MS132-16
1SAM350000R1011
10.0...16.0
240
11
22
MS132-25
1SAM350000R1014
20.0...25.0
375
15
29
MS132-32
1SAM350000R1015
25.0...32.0
480
18.5
35
MS450-40
1SAM450000R1005
28.0…40.0
520
22
41
MS450-50
1SAM450000R1007
36.0…50.0
650
30
55
MS495-63
1SAM550000R1007
45.0…63.0
819
37
66
MS495-75
1SAM550000R1008
57.0…75.0
975
45
80
MS495-90
1SAM550000R1009
70.0…90.0
1170
V 50/60 Hz
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24…60
100…250
24…60
100…250
24…60
100…250
24…60
100…250
24…60
100…250
V DC
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20…60
100…250
20…60
100…250
20…60
100…250
20…60
100…250
20…60
100…250
Allowed Type
setting (4)
current
A
0.25
CA4-10
Order code
BEA16-4
1SBN081306T1000
+
BEA26-4
CA4-10
1SBN082306T1000
1SBN010110R1010
+
BEA38-4
CA4-10
1SBN082306T2000
1SBN010110R1010
CA4-10
1SBN010110R1010
5
0.4
0.63
0.63
1
1.6
1.6
2.5
4
4
6.3
10
10
12
16
25
32
40
50
63
75
90
1SBC101914S0201 - Rev. A
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to
- 15 kW 400V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
(2) For other control voltages, see "Voltage code table".
(3) AF26 3-pole contactor can be selected for coordination type 2, 16 kA, 7.5 kW, 400 V - AC-3.
AF40 3-pole contactor can be selected for coordination type 2, 16 kA and 50 kA, 18.5 kW, 400 V - AC-3.
(4) BEA26-4 should be selected with MS116-12 … MS116-16 and AF26 … AF38.
BEA38-4 can only be selected with MS116-20 … MS116-32.
ABB | 5/7
Reversing starters protected by MS manual motor starters
Coordination type 1
Coordination type 1, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
Accessories
+
I>
BEA..-4
BER..-4
VEM4
Order code
1SAM350000R1002
Current
setting
range
Magnetic Rated control circuit
tripping voltage
current Uc min. ... Uc max.
A
0.16...0.25
A
2.44
Order code
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF12Z-30-10-21
AF12-30-10-13
AF16Z-30-10-21
AF16-30-10-13
AF26Z-30-00-21
AF26-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF38Z-30-00-21
AF38-30-00-13
AF52-30-00-11
AF52-30-00-13
AF65-30-00-11
AF65-30-00-13
AF80-30-00-11
AF80-30-00-13
AF80-30-00-11
AF80-30-00-13
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL156001R2110
1SBL157001R1310
1SBL176001R2110
1SBL177001R1310
1SBL236001R2100
1SBL237001R1300
1SBL276001R2100
1SBL277001R1300
1SBL296001R2100
1SBL297001R1300
1SBL367001R1100
1SBL367001R1300
1SBL387001R1100
1SBL387001R1300
1SBL397001R1100
1SBL397001R1300
1SBL397001R1100
1SBL397001R1300
(3)
(2)
0.09
0.3
MS132-0.4
1SAM350000R1003
0.25...0.40
3.9
0.12
0.44
MS132-0.63
1SAM350000R1004
0.40...0.63
6.14
0.18
0.6
MS132-0.63
1SAM350000R1004
0.40...0.63
6.14
0.25
0.85
MS132-1.0
1SAM350000R1005
0.63...1.00
11.5
0.37
1.1
MS132-1.6
1SAM350000R1006
1.00...1.60
18.4
0.55
1.5
MS132-1.6
1SAM350000R1006
1.00...1.60
18.4
0.75
1.9
MS132-2.5
1SAM350000R1007
1.60...2.50
28.75
1.1
2.7
MS132-4.0
1SAM350000R1008
2.50...4.00
50
1.5
3.6
MS132-4.0
1SAM350000R1008
2.50...4.00
50
2.2
4.9
MS132-6.3
1SAM350000R1009
4.00...6.30
78.75
3
6.5
MS132-10
1SAM350000R1010
6.30...10.0
150
4
8.5
MS132-10
1SAM350000R1010
6.30...10.0
150
5.5
11.5
MS132-12
1SAM350000R1012
8.00...12.0
180
7.5
15.5
MS132-16
1SAM350000R1011
10.0...16.0
240
11
22
MS132-25
1SAM350000R1014
20.0...25.0
375
15
29
MS132-32
1SAM350000R1015
25.0...32.0
480
18.5
35
MS450-40
1SAM450000R1005
28.0…40.0
520
22
41
MS450-50
1SAM450000R1007
36.0…50.0
650
30
55
MS495-63
1SAM550000R1007
45.0…63.0
819
37
66
MS495-75
1SAM550000R1008
57.0…75.0
975
45
80
MS495-90
1SAM550000R1009
70.0…90.0
1170
(1)
(2)
(3)
Type
V 50/60 Hz
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24…60
100…250
24…60
100…250
24…60
100…250
24…60
100…250
24…60
100…250
V DC
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20…60
100…250
20…60
100…250
20…60
100…250
20…60
100…250
20…60
100…250
MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 15 kW, 400 V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
For other control voltages, see "Voltage code table".
AF40 3-pole contactor can be selected for coordination type 1, 16 kA and 50 kA, 18.5 kW, 400 V - AC-3.
5/8 | ABB
Allowed Type
setting
current
A
0.25
0.4
Order code
BEA16-4
BER16-4
VEM4
1SBN081306T1000
1SBN081311R1000
1SBN030111R1000
BEA38-4
BER38-4
+
VEM4
+
+ 2x CA4-10
1SBN082306T2000
1SBN082311R1000
1SBN030111R1000
1SBN010110R1010
BER38-4
VEM4
CA4-10
BER65-4
VM96-4
+
+ 2x CA4-10
+ 2x CA4-01
1SBN082311R1000
1SBN030111R1000
1SBN010110R1010
1SBN083411R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
BER96-4
VM96-4
+
+ 2x CA4-10
+ 2x CA4-01
1SBN083911R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
+
+
0.63
0.63
1
1.6
1.6
2.5
4
4
6.3
9
9
12
16
25
32
38
50
63
75
80
+
+ 2x
1SBC101915S0201 - Rev. A
5
IEC
Type
(1)
AC-3, 400 V
Rated
operational
power current
kW
A
0.06 0.2
MS132-0.25
CA4-10
Reversing starters protected by MS manual motor starters
Coordination type 2
Coordination type 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz
Manual motor starters
Contactors
Accessories
+
I>
BEA..-4
BER..-4
VEM4
IEC
Type
(1)
AC-3, 400 V
Rated
operational
power current
kW
A
0.06 0.2
MS132-0.25
Order code
1SAM350000R1002
Current
setting
range
Magnetic Rated control circuit
tripping voltage
current Uc min. ... Uc max.
A
A
0.16...0.25 2.44
0.09
0.3
MS132-0.4
1SAM350000R1003
0.25...0.40 3.9
0.12
0.44
MS132-0.63
1SAM350000R1004
0.40...0.63 6.14
0.18
0.6
MS132-0.63
1SAM350000R1004
0.40...0.63 6.14
0.25
0.85
MS132-1.0
1SAM350000R1005
0.63...1.00 11.5
0.37
1.1
MS132-1.6
1SAM350000R1006
1.00...1.60 18.4
0.55
1.5
MS132-1.6
1SAM350000R1006
1.00...1.60 18.4
0.75
1.9
MS132-2.5
1SAM350000R1007
1.60...2.50 28.75
1.1
2.7
MS132-4.0
1SAM350000R1008
2.50...4.00 50
1.5
3.6
MS132-4.0
1SAM350000R1008
2.50...4.00 50
2.2
4.9
MS132-6.3
1SAM350000R1009
4.00...6.30 78.75
3
6.5
MS132-10
1SAM350000R1010
6.30...10.0 150
4
8.5
MS132-10
1SAM350000R1010
6.30...10.0 150
5.5
11.5
MS132-12
1SAM350000R1012
8.00...12.0 180
7.5
15.5
MS132-16
1SAM350000R1011
10.0...16.0 240
11
22
MS132-25
1SAM350000R1014
20.0...25.0 375
15
29
MS132-32
1SAM350000R1015
25.0...32.0 480
18.5
35
MS450-40
1SAM450000R1005
28.0…40.0 520
22
41
MS450-50
1SAM450000R1007
36.0…50.0 650
30
55
MS495-63
1SAM550000R1007
45.0…63.0 819
37
66
MS495-75
1SAM550000R1008
57.0…75.0 975
45
80
MS495-90
1SAM550000R1009
70.0…90.0 1170
Type
(3)
Order code
(2)
V 50/60 Hz
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24...60
100...250
24…60
100...250
24…60
100...250
24…60
100...250
24…60
100...250
24…60
100...250
V DC
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20...60
100...250
20…60
100...250
20…60
100...250
20…60
100...250
20…60
100...250
20…60
100...250
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF09Z-30-10-21
AF09-30-10-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF26Z-30-00-21
AF26-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF30Z-30-00-21
AF30-30-00-13
AF38Z-30-00-21
AF38-30-00-13
AF52-30-00-11
AF52-30-00-13
AF65-30-00-11
AF65-30-00-13
AF80-30-00-11
AF80-30-00-13
AF96-30-00-11
AF96-30-00-13
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL136001R2110
1SBL137001R1310
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL236001R2100
1SBL237001R1300
1SBL276001R2100
1SBL277001R1300
1SBL276001R2100
1SBL277001R1300
1SBL276001R2100
1SBL277001R1300
1SBL296001R2100
1SBL297001R1300
1SBL367001R1100
1SBL367001R1300
1SBL387001R1100
1SBL387001R1300
1SBL397001R1100
1SBL397001R1300
1SBL407001R1100
1SBL407001R1300
Allowed
setting
current
Order code
Type
(4)
5
A
0.25
0.4
CA4-10
BEA16-4
BER16-4
VEM4
1SBN081306T1000
1SBN081311R1000
1SBN030111R1000
BEA26-4
BER38-4
+
VEM4
+
+ 2x CA4-10
1SBN082306T1000
1SBN082311R1000
1SBN030111R1000
1SBN010110R1010
BEA38-4
+
BER38-4
+
VEM4
+ 2x CA4-10
1SBN082306T2000
1SBN082311R1000
1SBN030111R1000
1SBN010110R1010
BER65-4
+
VM96-4
+ 2x CA4-10
+ 2x CA4-01
1SBN083411R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
BER96-4
+
VM96-4
+ 2x CA4-10
+ 2x CA4-01
1SBN083911R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
+
+
0.63
0.63
1
1.6
1.6
2.5
4
4
6.3
10
10
12
16
25
32
40
50
63
75
90
1SBC101916S0201 - Rev. A
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to
- 15 kW 400V - AC-3 at 16 kA
- 4 kW, 400 V - AC-3 at 50 kA.
(2) For other control voltages, see "Voltage code table".
(3) AF26 3-pole contactor can be selected for coordination type 2, 16 kA, 7.5 kW, 400 V - AC-3.
AF40 3-pole contactor can be selected for coordination type 2, 16 kA and 50 kA, 18.5 kW, 400 V - AC-3.
(4) BEA26-4 should be selected with MS116-12 … MS116-16 and AF26 … AF38.
BEA38-4 can only be selected with MS116-20 … MS116-32.
ABB | 5/9
DOL and reversing starters protected by manual motor starters
With AF contactors - open type version in kit form
Wiring diagrams
Direct-on-line starters
5/L3
AC or DC local control
AC or DC remote control
KM1:5/L3
KM1:5/L3
33
33
43
44
Us
34
3/L2
1/L1
43
44
5/L3
33
34
3/L2
1-phase
1/L1
Power circuit
Q1
34
Us
33
Q1
34
V
M
13
13
KM1
KM1
14
I
14
I
43
Q1
KM1
44
Us
N
A2
Us
N
KM1
44
V
M
~
Q1
KM1:3/L2
KM1:3/L2
U
W
43
A2
14
A1
A1
13
5/L3
6/T3
14
A2
U
O
O
6/T3
3/L2
4/T2
4/T2
2/T1
1/L1
2/T1
5/L3
6/T3
13
3/L2
4/T2
6/T3
1/L1
2/T1
4/T2
I> I> I>
A1
KM1
5
I> I> I>
2/T1
Q1
Note: coil Uc 12-20 V DC : A1+, A2-
~
Reversing starters
Power circuit
AC or DC local control
5/L3
33
43
44
Us
34
3/L2
1/L1
KM2:5/L3
33 Q1 34
O
Q1
KM2
II
.4
KM1
.4
I
.3
.3
6/T3
4/T2
2/T1
I> I> I>
43 Q1 44
KM1
A2
V
W
M
~
(1)
A2
KM1
21
21
KM2
KM2
KM1
A1
A1
A2
A2
KM2
(3)
KM2:3/L2
U
(2)
22
Us
N
01
01
(2)
22
3/L2
1/L1
5/L3
6/T3
4/T2
2/T1
6/T3
4/T2
2/T1
A2
A1
5/L3
3/L2
KM2
A2
KM1
A1
1/L1
With VM
With VEM4
AC or DC remote control
KM2:5/L3
33 Q1 34
Us
O
.3
.3
II
.4
KM2
.4
KM1
I
A2
(1)
A2
21
KM2
(3)
Note: - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection
(Except for coil Uc 12-20 V DC : use VM4 with CA4).
- coil Uc 12-20 V DC : A1+, A2-
5/10 | ABB
KM1
KM1
A1
A1
A2
A2
KM2
1SBC101918S0201
KM2:3/L2
KM1
KM2
22
43 Q1 44
(2)
22
Us
N
01
01
(2)
21
With VM
With VEM4
DOL starters protected by M116 manual motor starters
With AF contactors - open type version in kit form
Main dimensions
mm, inches
70 2.76"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
186.8 7.35"
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
10
0.39"
75
2.95"
188 7.40"
17.5
0.69"
6
0.24"
80.1 3.15"
26.25
1.03"
5
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
5.5 0.22"
45 1.77"
5
0.20"
77 3.03"
35
1.38"
5
0.20"
MS116-0.16 ... MS116-16
+ BEA16-4
+ AF09, AF12, AF16
Ø 4.5 0.18"
M4 8-32UNC
17.5
0.69"
6
0.24"
81.1 3.19"17.5
72.2 2.84" 0.69"
26.25
1.03"
10 0.39"
10
0.39"
186.8 7.35"
186.8 7.35"
45 1.77"
10 0.39"
5.5
0.22"
26.25
1.03"
Ø 4.2 0.17"
M4 8-32UNC
Ø 4.2 0.17"
M4 8-32UNC
35
5
0.20" 1.38"
86 3.39"
5.5 0.22"
5
0.20"
5
0.20"
45 1.77"
86 3.39"
5
0.20"
5
0.20"
5.5 0.22"
5
0.20"
45 1.77"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
75
2.95"
35 mm EN/IEC 60715
5.5
0.22"
192 7.56"
188 7.40"
35 mm EN/IEC 60715
45 1.77"
75
2.95"
70 2.76"
6
0.24"
80.1 3.15"
5
0.20"
35
1.38"
5
0.20"
1SBC101919S0201
MS116-0.16 ... MS116-16
+ BEA26-4
+ AF26, AF30, AF38
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/11
DOL starters protected by M132 manual motor starters
With AF contactors - open type version in kit form
mm, inches
6
0.24"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
45 1.77"
26.25
1.03"
17.5
0.69"
5.5
0.22"
35 mm EN/IEC 60715
192 7.56"
10 0.39"
186.8 7.35"
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
81.1 3.19"
72.2 2.84"
10 0.39"
186.8 7.35"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
75
2.95"
188 7.40"
17.5
0.69"
6
0.24"
81.3 3.20"
72.4 2.85"
75
2.95"
Main dimensions
26.25
1.03"
5
Ø 4.2 0.17"
M4 8-32UNC
5.5 0.22"
77 3.03"
5
0.20"
77 3.03"
5
0.20"
35
1.38"
5
0.20"
Ø 4.5 0.18" 17.5
M4 8-32UNC0.69"
26.25
1.03"
10 0.39"
186.8 7.35"
186.8 7.35"
10 0.39"
Ø 4.2 0.17"
M4 8-32UNC
5.5 0.22"
86 3.39"
5
0.20"
35
1.38"
5
5
0.20" 0.20"
10
0.39"
5
0.20"
5
0.20"
5.5 0.22"
45 1.77"
86 3.39"
35
1.38"
5
0.20"
MS132-12 ... MS132-32
+ BEA38-4
+ AF26, AF30, AF38
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/12 | ABB
5
45 1.77"
0.20"
5
0.20"
35
1.38"
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
1SBC101923S0201
86 3.39"
26.25
1.03"
Ø 4.2 0.17"
M4 8-32UNC
5
0.20"
MS132-0.16 ... MS132-10
+ BEA26-4
+ AF26, AF30, AF38
5.5 0.22"
5
0.20"
45 1.77"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
6
0.24"
17.5
0.69"
5.5
0.22"
35 mm EN/IEC 60715
26.25
1.03"
5.5
0.22"
35 mm EN/IEC 60715
192 7.56"
192 7.56"
10 0.39"
186.8 7.35"
35 mm EN/IEC 60715
5.5
0.22"
81.1 3.19"
72.2 2.84"
6
0.24"
81.1 3.19"
72.2 2.84"
45 1.77"
10
0.39"
Ø 4.5 0.18"
M4 8-32UNC
45 1.77"
17.5
0.69"
6
0.24"
75
2.95"
72.4 2.85"
45 1.77"
5.5 0.22"
MS132-12 ... MS132-25
+ BEA16-4
+ AF09, AF12, AF16
81.3 3.20"
188 7.40"
5
45 1.77"
0.20"
75
2.95"
MS132-0.16 ... MS132-10
+ BEA16-4
+ AF09, AF12, AF16
35
1.38"
75
2.95"
45 1.77"
5
0.20"
5
0.20"
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
Reversing starters protected by M116 manual motor starters
With AF contactors - open type version in kit form
Main dimensions
mm, inches
75
2.95"
Ø 4.5 0.18"
M4 8-32UNC
45 1.77"
10
0.39"
70 2.76"
186.8 7.35"
5.5
0.22"
35 mm EN/IEC 60715
189.5 7.46"
17.5
0.69"
6
0.24"
97 3.82"
80.1 3.15"
10
0.39"
26.25
1.03"
5
17.5
0.69"
114 4.49"
80.1 3.15"
5
0.20"
Ø 4.5 0.18"
M4 8-32UNC
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
17.5
0.69"
26.25
1.03"
5
0.20"
5
0.20"
10
26.25
0.39"
1.03"
90 3.54"
90 3.54" 5.5 0.22"
5
0.20"
80
3.15"
5
5
0.20" 0.20"
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
70
2.76"
70
2.76"
10
0.39"
198 7.80"
5.5
0.22"
198 7.80"
45 1.77"
70 2.76"
35 mm EN/IEC 60715
5.5
0.22"
35 mm EN/IEC 60715
198 7.80"
198 7.80"
45 1.77"
75
2.95"
75
2.95"
114 4.49"
80.1 3.15"
70 2.76"
35
1.38"
10
0.39"
MS116-0.16 ... MS116-16
+ BEA16-4, BER16-4, VEM4
+ AF09, AF12, AF16
5
0.20"
6
0.24"
3,8
0.15"
90 3.54"
6
0.24"
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
80
3.15"
5
0.20"
5.5 0.22"
1SBC101924S0201
MS116-0.16 ... MS116-16
+ BEA26-4, BER38-4, VEM4, CA4-10
+ AF26, AF30, AF38
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/13
Reversing starters protected by M132 manual motor starters
With AF contactors - open type version in kit form
mm, inches
81.1 3.19"
17.5
0.69"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39"
10
0.39"
72.2 2.84"
45 1.77"
10
0.39"
70
2.76"
70
2.76"
5
26.25
1.03"
5
0.20"
26.25
1.03"
5
0.20"
10
0.39"
5.5
0.22"
35 mm EN/IEC 60715
193.5
186.8 7.62"
7.35"
35 mm EN/IEC 60715
5.5
0.22"
Ø 4.2 0.17"
M4 8-32UNC
5
0.20"
5
0.20"
17.5
17.5
0.69"
0.69"
Ø 4.5
Ø 4.5
0.18"
0.18"
M4M4
8-32UNC
8-32UNC
72.2
72.2
2.84"
2.84"
45 1.77"
45 1.77"
5
5
0.20"
0.20"
26.25
26.25
1.03"
1.03"
70
70
2.76"
2.76"
10 10
0.39"
0.39"
70
2.76"
5
0.20"
26.25
1.03"
186.8 7.35"
186.8 7.35"
201.5 7.93"
201.5
186.87.93"
7.35"
10
0.39"
5.55.5
0.22"
0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5,5 0.22"
35 mm EN/IEC 60715
81.1
81.1
3.19"
3.19"
10
0.39"
72.4 2.85"
Ø 4.5 0.18"
M4 8-32UNC
MS132-0.16 ... MS132-10
+ BEA26-4, BER38-4, VEM4, CA4-10
+ AF26, AF30, AF38
80
3.15"
90 90
3.54"
3.54"
5
0.20"
5.55.5
0.22"
0.22"
5
5
0.20"
0.20"
5
0.20"
5 5
0.20"
0.20"
80 80
3.15"
3.15"
5 5
0.20"
0.20"
MS132-12 ... MS132-32
+ BEA38-4, BER38-4, VEM4, CA4-10
+ AF26, AF30, AF38
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/14 | ABB
5
0.20"
5
0.20"
5.5 0.22"
5
5
0.20"
0.20"
Ø 4.2
Ø 4.2
0.17"
0.17"
M4M4
8-32UNC
8-32UNC
Ø 4.2 0.17"
M4 8-32UNC
90 3.54"
5
0.20"
10
10
0.39"
0.39"
17.5
0.69"
6
6
0.24"
0.24"
114114
4.49"
4.49"
6
0.24"
75
2.95"
81.3 3.20"
45 1.77"
80
3.15"
5
0.20"
MS132-12 ... MS132-25
+ BEA16-4, BER16-4, VEM4
+ AF09, AF12, AF16
114 4.49"
198 7.80"
5
0.20"
75
75
2.95"
2.95"
MS132-0.16 ... MS132-10
+ BEA16-4, BER16-4, VEM4
+ AF09, AF12, AF16
80
90 3.54"
3.15"
5
0.20"
3.8
0.15"
3.8
0.15"
90 3.54"
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
1SBC101925S0201
45 1.77"
72.4 2.85"
6
0.24"
Ø 4.5 0.18"
M4 8-32UNC
75
75
2.95"
189.5 7.46"
17.5
0.69"
2.95"
6
0.24"
97 3.82"
97 3.82"
81.3 3.20"
186.8 7.35"
Main dimensions
N1
5
ABB | 5/15
DOL starters protected by moulded-case circuit-breakers and
overload relays
With AF contactors - Open type version in kit form
Application
Full voltage direct-on-line (DOL) starting for controlling three-phase asynchronous motors is a simple and
economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a starting
current 5.5 to 7 times nominal current.
I/In C/Cn
7
6
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
1SFC101191V0001
2
5
XT2S 160 + BEA140/XT2 +
AF140-30-11
C
1
0
10
30
60
80
100
Coordination types
The contactor and the moulded-case circuit-breaker control and protect motors against overload and shortcircuits according to coordination types 1 and 2 (IEC 60947-4-1/EN 60947-4-1) defining the anticipated level
of service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts light welding is acceptable.
Main Technical Data
Standards
IEC 60947-4-1 / EN 60947-4-1
Rated operational voltage Ue max.
400 V - 50/60 Hz
Rated insulation voltage Ui
acc. to IEC 60947-4-1
690 V
acc. to UL / CSA
600 V
≤ 15 starts/hour - 80 % max. load factor - with max. 1.5 s starting time
≤ 30 starts/hour - 50 % max. load factor - with max. 1.5 s starting time
Switching frequency
Ambient air temperature
1SFC101190V0001
Close to the device
< 55 °C
IP20
Degree of protection
Mounting positions
XT2S 160 + BEA140/XT2 +
AF140-30-11 + EF146
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Direct-on-line
MCCB + AF
5/16 | ABB
Direct-on-line
MCCB + AF + OL
1SBC101973S0201
Pos. 1
DOL starters protected by moulded-case circuit-breakers and
overload relays
With AF contactors - Open type version in kit form
Description
MCCB
Moulded-case circuit-breaker
including motor protection
You can easily assemble a direct-online starter by using the BEA connection
bars. It is used to electrically connect
MCCB moulded-case circuit-breaker and
AF116 ... AF370 contactor, AC or DC
operated.
MCCB
Moulded-case circuit-breaker
(magnetic only)
Select now easily and quickly your
starter in the following pages for coordination type 1 or 2 at 400 V, 50 / 60 Hz,
Iq = 50 kA up to 200 kW.
AF116 ... AF370
Contactor
BEA
Connection bar
5
AF116 ... AF370
Contactor
TF
Thermal overload relay
EF
Electronic overload relay
1SBC101973S0201
BEA
Connection bar
For the full coordination tables:
www.abb.com/lowvoltage then go to the right
menu: "Support", select: "Online Product Selection
Tools" then select "Coordination Tables for motor
protection"
ABB | 5/17
DOL starters protected by MCCB including motor protection
Coordination type 1 or 2
Coordination type 1 or 2, AC-3, 50 kA, 400 V, 50/60 Hz
MCCB
+
5
Max. allowed
thermal setting
Base
Type
Order code
1440
116
XT2S 160
1SDA068164R1
+ Ekip M-LIU In160
1SDA067355R1
132
1920
140
XT2S 160
1SDA068164R1
+ Ekip M-LIU In160
1SDA067355R1
90
160
2400
190
T4S 250 PR222MP In200
1SDA054527R1
Included
-
110
195
2880
205
T5S 400 PR222MP In320
1SDA054553R1
Included
-
132
230
3600
265
T5S 400 PR222MP In400
1SDA054554R1
Included
-
160
280
4400
305
T5S 400 PR222MP In400
1SDA054554R1
Included
-
IEC
AC-3, 400 V
Rated
Rated
power
current
kW
A
Magnetic
triping
current
setting
55
97
75
5/18 | ABB
Trip unit
Type
Order code
A
Connection bars
Control voltage
Uc min. ... Uc max.
V 50/60 Hz
V DC
24...60
20...60
Type
Order code
Type
Order code
AF116-30-11-11
1SFL427001R1111
BEA140/XT2
1SFN084206R1000
BEA205/T4
1SFN084806R1001
BEA370/T5
1SFN085406R1000
100...250
100...250
AF116-30-11-13
1SFL427001R1311
24...60
20...60
AF140-30-11-11
1SFL447001R1111
100...250
100...250
AF140-30-11-13
1SFL447001R1311
24...60
20...60
AF190-30-11-11
1SFL487002R1111
100...250
100...250
AF190-30-11-13
1SFL487002R1311
24...60
20...60
AF205-30-11-11
1SFL527002R1111
100...250
100...250
AF205-30-11-13
1SFL527002R1311
24...60
20...60
AF265-30-11-11
1SFL547002R1111
100...250
100...250
AF265-30-11-13
1SFL547002R1311
24...60
20...60
AF305-30-11-11
1SFL587002R1111
100...250
100...250
AF305-30-11-13
1SFL587002R1311
5
1SBC101975S0201
Contactors
ABB | 5/19
DOL starters protected by MCCB (magnetic only) and overload relays
Coordination type 1 or 2
Coordination type 1 or 2, AC-3, 50 kA, 400 V, 50/60 Hz
MCCB
Contactors
Thermal overload relays
5
IEC
AC-3, 400 V
Rated
Rated
power
current
kW
A
Magnetic
triping
current
55
1600
75
90
110
97
132
160
195
Type
Order code
Control voltage
Uc min. ... Uc max.
V 50/60 Hz
V DC
XT2S 160 MA 160
1SDA076530R1
24...60
20...60
AF116-30-11-11
1SFL427001R1111
100...250
100...250
AF116-30-11-13
1SFL427001R1311
A
1920
2250
2720
XT2S 160 MA 160
XT4S 250 Ekip I In250
T4S 320 PR221-I In320
1SDA076530R1
1SDA068480R1
1SDA054126R1
Type
Order code
24...60
20...60
AF140-30-11-11
1SFL447001R1111
100...250
100...250
AF140-30-11-13
1SFL447001R1311
24...60
20...60
AF190-30-11-11
1SFL487002R1111
100...250
100...250
AF190-30-11-13
1SFL487002R1311
24...60
20...60
AF205-30-11-11
1SFL527002R1111
100...250
100...250
AF205-30-11-13
1SFL527002R1311
Electronic overload relays
55
75
90
110
132
160
200
97
132
160
195
230
280
350
5/20 | ABB
1600
1920
2250
2720
3200
4000
5040
XT2S 160 MA 160
XT2S 160 MA 160
XT4S 250 Ekip I In250
T4S 320 PR221-I In320
T5S 400 PR221-I In400
T5S 400 PR221-I In400
T5S 630 PR221-I In630
1SDA076530R1
1SDA076530R1
1SDA068480R1
1SDA054126R1
1SDA054335R1
1SDA054335R1
1SDA054405R1
24...60
20...60
AF116-30-11-11
1SFL427001R1111
100...250
100...250
AF116-30-11-13
1SFL427001R1311
24...60
20...60
AF140-30-11-11
1SFL447001R1111
100...250
100...250
AF140-30-11-13
1SFL447001R1311
24...60
20...60
AF190-30-11-11
1SFL487002R1111
100...250
100...250
AF190-30-11-13
1SFL487002R1311
24...60
20...60
AF205-30-11-11
1SFL527002R1111
100...250
100...250
AF205-30-11-13
1SFL527002R1311
24...60
20...60
AF265-30-11-11
1SFL547002R1111
100...250
100...250
AF265-30-11-13
1SFL547002R1311
24...60
20...60
AF305-30-11-11
1SFL587002R1111
100...250
100...250
AF305-30-11-13
1SFL587002R1311
24...60
20...60
AF370-30-11-11
1SFL607002R1111
100...250
100...250
AF370-30-11-13
1SFL607002R1311
Overload relays
Max. allowed Type
setting
current
Order code
Type
Order code
5
A
A
80...110
110
TF140DU-110
1SAZ431201R1002
110...142
140
TF140DU-142
1SAZ431201R1004
130...175
175
TA200DU-175
155...200
200
54...150
BEA140/XT2
1SFN084206R1000
1SAZ421201R1005
BEA205/XT4
1SFN084806R1000
TA200DU-200
1SAZ421201R1006
BEA205/T4
1SFN084806R1001
116
EF146-150
1SAX351001R1101
BEA140/XT2
1SFN084206R1000
54...150
140
EF146-150
1SAX351001R1101
63...210
190
EF205-210
1SAX531001R1101
BEA205/XT4
1SFN084806R1000
63...210
205
EF205-210
1SAX531001R1101
BEA205/T4
1SFN084806R1001
115...380
265
EF370-380
1SAX611001R1101
BEA370/T5
1SFN085406R1000
115...380
305
EF370-380
1SAX611001R1101
115...380
350
EF370-380
1SAX611001R1101
1SBC101974S0201
Setting
ranges
Connection bars
ABB | 5/21
DOL starters protected by moulded-case circuit-breakers and
overload relays
With AF contactors - Open type version in kit form
Direct-on-line starters
K5 1
Q
5/L3
3/L2
1/L1
Protected by MCCB (magnetic only) and overload relays
5/L3
3/L2
1/L1
Protected by MCCB including motor protection
Q1
T1/L1
1>
1> 1>
ᶯ
0
1>
6/T3
T1/L2
1>
M - L1U
4/T2
E kip
2/T1
5
Y01
13
M-1
E kip
KM1
M - LR1U
V
M
W
97
98
U
6/T3
4/T2
2/T1
TEST
STOP
V
M
W
1SBC101976S0201
U
6/T3
4/T2
2/T1
14
95
M
KM1
96
A1
A
RESET
A2
14
13
A2
5/L3
3/L2
1/L1
A1
E kip
5/L3
m>3
3/L2
1/L1
1 >>>
T1/L3
5/22 | ABB
DOL starters protected by MCCB, including motor protection
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
30 1.18"
126 4.96"
8x
M4 8-32 UNC
43.2 1.70"
289 11.38"
112 4.41"
90 3.54"
100 3.94"
5
XT2S 160 + Ekip M-LIU In160
+ BEA140/XT2
+ AF116, AF140, AF146
152 5.98"
35 1.39"
12 x
M5 10-24 UNC
39.5
1.56"
1SFC101187C0201
165 6.50"
410 16.14"
176 6.93"
105 4.13"
T4S
+ BEA205/T4
+ AF190, AF205
ABB | 5/23
DOL starters protected by MCCB, including motor protection
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
180 7.09"
46.5 1.83"
8x
M5 10-24 UNC
176 6.93"
140 5.51"
45 1.77"
187 7.36"
441 17.36"
5
43.75 1.72"
1SFC101188C0201
T5S
+ BEA370/T5
+ AF265, AF305, AF370
5/24 | ABB
DOL starters protected by MCCB (magnetic only) and
thermal overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
126 4.96"
30 1.18"
8x
M4 8-32 UNC
100 3.94"
5
45 1.77"
398 15.67"
43.2 1.70"
112 4.41"
90 3.54"
82.3 3.24"
4x
M5 10-24 UNC
37 1.46"
50 1.97"
1SFC101189C0201
XT2S
+ BEA140/XT2
+ AF116, AF140, AF146
+ TF140 thermal overload relay
ABB | 5/25
DOL starters protected by MCCB (magnetic only) and
thermal overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
35 1.39"
152 5.98"
4x
M4 8-32 UNC
139 5.47"
105 4.13"
165 6.50"
41
1.61"
8x
M5 10-24 UNC
82 3.23"
25.5
1.0"
488 19.21"
5
37 1.46"
50 1.97"
1SFC101190C0201
XT4S
+ BEA205/XT4
+ AF190, AF205
+ TA200DU thermal overload relay
5/26 | ABB
DOL starters protected by MCCB (magnetic only) and
thermal overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
152 5.98"
35 1.39"
12 x
M5 10-24 UNC
176 6.93"
105 4.13"
82 3.23"
25.5
1.0"
165 6.50"
527 20.75"
39.5
1.56"
5
37 1.46"
50 1.97"
1SFC101191C0201
T4S
+ BEA205/T4
+ AF190, AF205
+ TA200DU thermal overload relay
ABB | 5/27
DOL starters protected by MCCB (magnetic only) and
electronic overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
126 4.96"
30 1.18"
10 x
M4 8-32 UNC
43.2 1.70"
112 4.41"
90 3.54"
100 3.94"
43.8 1.72"
408 16.06"
5
21.5
94.7 3.73"
0.85"
37 1.46"
2x
M5 10-24 UNC
1SFC101192C0201
XT2S
+ BEA140/XT2
+ AF116, AF140, AF146
+ EF146 electronic overload relay
5/28 | ABB
DOL starters protected by MCCB (magnetic only) and
electronic overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
35 1.39"
152 5.98"
4x
M4 8-32 UNC
112 4.42"
20.5
165 6.50"
1.61"
5
0.81"
517.5 20.37"
41
139 5.47"
105 4.13"
8x
M5 10-24 UNC
1SFC101193C0201
XT4S
+ BEA205/XT4
+ AF190, AF205
+ EF205 electronic overload relay
ABB | 5/29
DOL starters protected by MCCB (magnetic only) and
electronic overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
152 5.98"
35 1.39"
12 x
M5 10-24 UNC
176 6.93"
105 4.13"
20.5
112 4.42"
0.81"
165 6.50"
556.5 21.91"
39.5 1.56"
5
1SFC101194C0201
T4S
+ BEA205/T4
+ AF190, AF205
+ EF205 electronic overload relay
5/30 | ABB
DOL starters protected by MCCB (magnetic only) and
electronic overload relays
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
180 7.09"
46.5 1.83"
12 x
M5 10-24 UNC
176 6.93"
140 5.51"
187 7.36"
112 4.41"
29 1.14"
600.5 23.64"
45 1.77"
5
35 1.38"
43.75 1.72"
1SFC101195C0201
T5S
+ BEA370/T5
+ AF265, AF305, AF370
+ EF370 electronic overload relay
ABB | 5/31
DOL and reversing starters protected by overload relays
With AF contactors - Open type version in kit form
Application
Full voltage direct-on-line and reversing starting for controlling three-phase asynchronous motors is a simple
and economic solution characterised by a high starting torque (1.9 to 2.1 times full-speed torque) and a
starting current 5.5 to 7 times nominal current.
I/In C/Cn
7
1SBC100058V0014
6
I
5
I = current
C = torque
In = nominal current
Cn = nominal torque
4
3
AF09-30-10 + TF42
2
C
1
5
0
10
30
60
80
100
Coordination Types
1SFC101153V0001
The contactor, the short-circuit protection device and the thermal overload relay control and protect motors
against overload and short-circuits according to coordination types 1 and 2 (IEC 60947-4-1 / EN 60947-4-1)
defining the anticipated level of service continuity as follow:
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will not be able to then operate without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts light welding is acceptable.
AF140-30-11 + TF140DU
Main Technical Data
Standards
IEC 60947-4-1 / EN 60947-4-1
Rated operational voltage Ue max.
690 V - 50/60 Hz
Rated insulation voltage Ui
acc. to IEC 60947-4-1
690 V
acc. to UL / CSA
600 V
Ambient air temperature
1SBC100059V0014
Close to the device
≤ 60 °C (TF42: 38 A above ≤ 50 °C)
Degree of protection
IP20
Switching frequency
Refer to "Switching frequency diagrams" page
AF09-30-10 + BER16-4 + VEM4
+ TF42
AF140-30-11 + BER140-4 + VM19
+ TF140DU
5/32 | ABB
Pos. 1
Direct-on-line
Pos. 1
Reversing
1SBC101920S0201
1SFC101152V0001
Mounting positions
DOL and reversing starters protected by overload relays
With AF contactors - Open type version in kit form
Direct-On-Line
starters
Description
Reversing starters for AF09 ... AF38
You can easily assemble a direct-on-line
starter by connecting AF contactor and
TF thermal overload relay or EF electronic
overload relay.
Fixing clip
A2
AF09 ... AF96
Contactor
AF09 ... AF38
Contactors
A2
VM4
Mechanical
interlock unit
VE4
Electrical
interlock
block
TF
Thermal overload relay
EF
Electronic overload relay
TF42
Thermal
overload relay
EF19, EF45
Electronic
overload relay
BER..-4
Connection set
Reversing starters for AF116 ... AF370
BER..-4
Connection set
You can also easily assemble reversing
starter thanks to our complete range of
accessories:
–– For AF09 ... AF38, use VEM4 mechanical and electrical interlock set for
reversing starter in 90 mm width.
It includes:
-- VM4 mechanical interlock unit including 2 fixing clips
-- VE4 electrical interlock block with
A2-A2 connection.
–– For AF40 ... AF370, use VM mechanical interlock unit and additional auxiliary
contact blocks for electrical interlocking.
–– BER..-4 connection set: it assures a
safe and simple reversing connection
between both contactor main terminals.
5
Select now easily and quickly your
starter in the following pages at 400 V,
up to 200 kW.
For the full coordination tables:
www.abb.com/lowvoltage then go to the right
menu: "Support", select: "Online Product Selection
Tools" then select "Coordination Tables for motor
protection"
AF contactor
with built-in
cable clamps
VM
Mechanical
interlock
unit
AF contactor
with built-in
cable clamps
1SBC101920S0201
BER..-4
Connection set
TF/TA
Thermal overload relay
EF
Electronic overload relay
ABB | 5/33
Direct-On-Line starters protected by thermal overload relays
With AF contactors - Open type version in kit form
Contactors
IEC
AC-3, 400 V
Rated Rated
power current
Control voltage
Uc min. ... Uc max.
kW
A
V 50/60 Hz V DC
4
8.5
24...60
20...60
AF09Z-30-10-21 1SBL136001R2110
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12Z-30-10-21 1SBL156001R2110
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16Z-30-10-21 1SBL176001R2110
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26Z-30-00-21 1SBL236001R2100
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30Z-30-00-21 1SBL276001R2100
100...250
100...250
AF30-30-00-13
24...60
20...60
AF38Z-30-00-21 1SBL296001R2100
100...250
100...250
AF38-30-00-13
1SBL297001R1300
24...60
20...60
AF40-30-00-11
1SBL347001R1100
100...250
100...250
AF40-30-00-13
1SBL347001R1300
24…60
20…60
AF52-30-00-11
1SBL367001R1100
100-250
100-250
AF52-30-00-13
1SBL367001R1300
24…60
20…60
AF65-30-00-11
1SBL387001R1100
100-250
100-250
AF65-30-00-13
1SBL387001R1300
24…60
20…60
AF80-30-00-11
1SBL397001R1100
100-250
100-250
AF80-30-00-13
1SBL397001R1300
24…60
20…60
AF96-30-00-11
1SBL407001R1100
100-250
100-250
AF96-30-00-13
1SBL407001R1300
24…60
20…60
AF116-30-11-11 1SFL427001R1111
100-250
100-250
AF116-30-11-13 1SFL427001R1311
24…60
20…60
AF140-30-11-11 1SFL447001R1111
100-250
100-250
AF140-30-11-13 1SFL447001R1311
24…60
20…60
AF190-30-11-11 1SFL487002R1111
100-250
100-250
AF190-30-11-13 1SFL487002R1311
24…60
20…60
AF205-30-11-11 1SFL527002R1111
100-250
100-250
AF205-30-11-13 1SFL527002R1311
5.5
7.5
11
15
18.5
18.5
22
30
37
45
55
75
90
110
11.5
15.5
22
29
35
35
41
55
66
80
97
132
160
195
Type
Order code
Setting ranges
Type
Order code
7.60...10.0
TF42-10
1SAZ721201R1043
10.0...13.0
TF42-13
1SAZ721201R1045
13.0...16.0
TF42-16
1SAZ721201R1047
20.0...24.0
TF42-24
1SAZ721201R1051
29.0...35.0
TF42-35
1SAZ721201R1053
35.0...38.0/40.0
TF42-38
1SAZ721201R1055
30.0...40.0
TF65-40
1SAZ811201R1003
36.00…47.0
TF65-47
1SAZ811201R1004
50.0…60.0
TF65-60
1SAZ811201R1006
57.0…68.0
TF96-68
1SAZ911201R1003
75.0..87.0
TF96-87
1SAZ911201R1005
80…110
TF140DU-110
1SAZ431201R1002
100…135
TF140DU-135
1SAZ431201R1003
130…175
TA200DU-175
1SAZ421201R1005
150…200
TA200DU-200
1SAZ421201R1006
Accessories
(1)
A
1SBL137001R1310
1SBL157001R1310
1SBL177001R1310
1SBL237001R1300
1SBL277001R1300
(1) For other control voltages, see "Voltage code table".
Note : for rated power above 110 kW, refer to "Starters protected by electronic overload relays".
1SBC101921S0201
5
Thermal overload relays
5/34 | ABB
Reversing starters protected by thermal overload relays
With AF contactors - Open type version in kit form
Contactors
Thermal overload relays
Accessories
+
BER..-4
VEM4
IEC
AC-3, 400 V
Rated Rated
power current
kW
A
Control voltage
Uc min. ... Uc max.
4
24...60
20...60
AF09Z-30-10-21 1SBL136001R2110
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12Z-30-10-21 1SBL156001R2110
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16Z-30-10-21 1SBL176001R2110
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26Z-30-00-21 1SBL236001R2100
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30Z-30-00-21 1SBL276001R2100
100...250
100...250
AF30-30-00-13
24...60
20...60
AF38Z-30-00-21 1SBL296001R2100
100...250
100...250
AF38-30-00-13
1SBL297001R1300
24...60
20...60
AF40-30-00-11
1SBL347001R1100
100...250
100...250
AF40-30-00-13
1SBL347001R1300
24...60
20...60
AF52-30-00-11
1SBL367001R1100
100...250
100...250
AF52-30-00-13
1SBL367001R1300
24...60
20...60
AF65-30-00-11
1SBL387001R1100
100...250
100...250
AF65-30-00-13
1SBL387001R1300
24...60
20...60
AF80-30-00-11
1SBL397001R1100
100...250
100...250
AF80-30-00-13
1SBL397001R1300
24...60
20...60
AF96-30-00-11
1SBL407001R1100
100...250
100...250
AF96-30-00-13
1SBL407001R1300
24...60
20...60
AF116-30-11-11 1SFL427001R1111
100...250
100...250
AF116-30-11-13 1SFL427001R1311
24...60
20...60
AF140-30-11-11 1SFL447001R1111
100...250
100...250
AF140-30-11-13 1SFL447001R1311
24...60
20...60
AF190-30-11-11 1SFL487002R1111
100...250
100...250
AF190-30-11-13 1SFL487002R1311
24...60
20...60
AF205-30-11-11 1SFL527002R1111
100...250
100...250
AF205-30-11-13 1SFL527002R1311
5.5
7.5
11
15
18.5
18.5
22
30
37
45
55
75
90
110
8.5
11.5
15.5
22
29
35
35
41
55
66
80
97
132
160
195
Type
Order code
Setting ranges
Type
Order code
TF42-10
1SAZ721201R1043
Type
CA4-10
Order code
(1)
V 50/60 Hz V DC
A
7.60...10.0
BER16-4
VEM4
1SBN081311R1000
1SBN030111R1000
BER38-4
+
VEM4
+ 2x CA4-10
1SBN082311R1000
1SBN030111R1000
1SBN010110R1010
BER65-4
+
VM96-4
+ 2x CA4-10
+ 2x CA4-01
1SBN083411R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
BER96-4
+
VM96-4
+ 2x CA4-10
+ 2x CA4-01
1SBN083911R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
+
1SBL137001R1310
10.0...13.0
TF42-13
1SAZ721201R1045
13.0...16.0
TF42-16
1SAZ721201R1047
20.0...24.0
TF42-24
1SAZ721201R1051
29.0...35.0
TF42-35
1SAZ721201R1053
35.0...38.0/40.0
TF42-38
1SAZ721201R1055
30.0...40.0
TF65-40
1SAZ811201R1003
36.00…47.0
TF65-47
1SAZ811201R1004
50.0…60.0
TF65-60
1SAZ811201R1006
57.0…68.0
TF96-68
1SAZ911201R1003
75.0..87.0
TF96-87
1SAZ911201R1005
80…110
TF140DU-110
1SAZ431201R1002
5
1SBL157001R1310
1SBL177001R1310
1SBL237001R1300
1SBL277001R1300
100…135
TF140DU-135
1SAZ431201R1003
130…175
TA200DU-175
1SAZ421201R1005
150…200
TA200DU-200
+
BER140-4 1SFN084211R1000
VM19
1SFN030300R1000
+
BER205-4 1SFN084811R1000
VM19
1SFN030300R1000
1SAZ421201R1006
1SBC101922S0201
(1) For other control voltages, see "Voltage code table".
Note : for rated power above 110 kW, refer to "Starters protected by electronic overload relays".
ABB | 5/35
Direct-On-Line starters protected by electronic overload relays
With AF contactors - Open type version in kit form
Contactors
IEC
AC-3, 400 V
Rated Rated
power current
Control voltage
Uc min. ... Uc max.
kW
A
V 50/60 Hz V DC
4
8.5
24...60
20...60
AF09Z-30-10-21 1SBL136001R2110
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12Z-30-10-21 1SBL156001R2110
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16Z-30-10-21 1SBL176001R2110
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26Z-30-00-21 1SBL236001R2100
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30Z-30-00-21 1SBL276001R2100
100...250
100...250
AF30-30-00-13
24...60
20...60
AF38Z-30-00-21 1SBL296001R2100
100...250
100...250
AF38-30-00-13
1SBL297001R1300
24...60
20...60
AF40-30-00-11
1SBL347001R1100
100...250
100...250
AF40-30-00-13
1SBL347001R1300
24…60
20…60
AF52-30-00-11
1SBL367001R1100
100-250
100-250
AF52-30-00-13
1SBL367001R1300
24…60
20…60
AF65-30-00-11
1SBL387001R1100
100-250
100-250
AF65-30-00-13
1SBL387001R1300
24…60
20…60
AF80-30-00-11
1SBL397001R1100
100-250
100-250
AF80-30-00-13
1SBL397001R1300
24…60
20…60
AF96-30-00-11
1SBL407001R1100
100-250
100-250
AF96-30-00-13
1SBL407001R1300
24…60
20…60
AF116-30-11-11 1SFL427001R1111
100-250
100-250
AF116-30-11-13 1SFL427001R1311
24…60
20…60
AF140-30-11-11 1SFL447001R1111
100-250
100-250
AF140-30-11-13 1SFL447001R1311
24…60
20…60
AF190-30-11-11 1SFL487002R1111
100-250
100-250
AF190-30-11-13 1SFL487002R1311
24…60
20…60
AF205-30-11-11 1SFL527002R1111
100-250
100-250
AF205-30-11-13 1SFL527002R1311
24…60
20…60
AF265-30-11-11 1SFL547002R1111
100-250
100-250
AF265-30-11-13 1SFL547002R1311
24…60
20…60
AF305-30-11-11 1SFL587002R1111
100-250
100-250
AF305-30-11-13 1SFL587002R1311
24…60
20…60
AF370-30-11-11 1SFL607002R1111
100-250
100-250
AF370-30-11-13 1SFL607002R1311
5.5
7.5
11
15
18.5
18.5
22
30
37
45
55
75
90
110
132
160
200
11.5
15.5
22
29
35
35
41
55
66
80
97
132
160
195
230
280
350
Type
Order code
Setting ranges
Type
Order code
5.70…18.9
EF19-18.9
1SAX121001R1105
5.70…18.9
EF19-18.9
1SAX121001R1105
5.70…18.9
EF19-18.9
1SAX121001R1105
9.00…30.0
EF45-30
1SAX221001R1101
9.00…30.0
EF45-30
1SAX221001R1101
15.0…45.0
EF45-45
1SAX221001R1102
25.0...70.0
EF65-70
1SAX331001R1101
25.0…70.0
EF65-70
1SAX331001R1101
25.0…70.0
EF65-70
1SAX331001R1101
36…100
EF96-100
1SAX341001R1101
36…100
EF96-100
1SAX341001R1101
54…150
EF146-150
1SAX351001R1101
54…150
EF146-150
1SAX351001R1101
63…210
EF205-210
1SAX531001R1101
63…210
EF205-210
1SAX531001R1101
115…380
EF370-380
1SAX611001R1101
115…380
EF370-380
1SAX611001R1101
115…380
EF370-380
1SAX611001R1101
Accessories
(1)
A
1SBL137001R1310
1SBL157001R1310
1SBL177001R1310
1SBL237001R1300
1SBL277001R1300
(1) For other control voltages, see "Voltage code table".
1SBC101948S0201
5
Electronic overload relays
5/36 | ABB
Reversing starters protected by electronic overload relays
With AF contactors - Open type version in kit form
Contactors
Electronic overload relays
Accessories
+
BER..-4
VEM4
IEC
AC-3, 400 V
Rated Rated
power current
kW
A
Control voltage
Uc min. ... Uc max.
4
24...60
20...60
AF09Z-30-10-21 1SBL136001R2110
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12Z-30-10-21 1SBL156001R2110
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16Z-30-10-21 1SBL176001R2110
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26Z-30-00-21 1SBL236001R2100
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30Z-30-00-21 1SBL276001R2100
100...250
100...250
AF30-30-00-13
24...60
20...60
AF38Z-30-00-21 1SBL296001R2100
100...250
100...250
AF38-30-00-13
1SBL297001R1300
24...60
20...60
AF40-30-00-11
1SBL347001R1100
100...250
100...250
AF40-30-00-13
1SBL347001R1300
24...60
20...60
AF52-30-00-11
1SBL367001R1100
100...250
100...250
AF52-30-00-13
1SBL367001R1300
24...60
20...60
AF65-30-00-11
1SBL387001R1100
100...250
100...250
AF65-30-00-13
1SBL387001R1300
24...60
20...60
AF80-30-00-11
1SBL397001R1100
100...250
100...250
AF80-30-00-13
1SBL397001R1300
24...60
20...60
AF96-30-00-11
1SBL407001R1100
100...250
100...250
AF96-30-00-13
1SBL407001R1300
24...60
20...60
AF116-30-11-11 1SFL427001R1111
100...250
100...250
AF116-30-11-13 1SFL427001R1311
24...60
20...60
AF140-30-11-11 1SFL447001R1111
100...250
100...250
AF140-30-11-13 1SFL447001R1311
24...60
20...60
AF190-30-11-11 1SFL487002R1111
100...250
100...250
AF190-30-11-13 1SFL487002R1311
24...60
20...60
AF205-30-11-11 1SFL527002R1111
100...250
100...250
AF205-30-11-13 1SFL527002R1311
24...60
20...60
AF265-30-11-11 1SFL547002R1111
100...250
100...250
AF265-30-11-13 1SFL547002R1311
24...60
20...60
AF305-30-11-11 1SFL587002R1111
100...250
100...250
AF305-30-11-13 1SFL587002R1311
24...60
20...60
AF370-30-11-11 1SFL607002R1111
100...250
100...250
AF370-30-11-13 1SFL607002R1311
5.5
7.5
11
15
18.5
18.5
22
30
37
45
55
75
90
110
132
160
200
8.5
11.5
15.5
22
29
35
35
41
55
66
80
97
132
160
195
230
280
350
Type
Order code
Setting ranges
Type
Order code
EF19-18.9
1SAX121001R1105
Type
CA4-10
Order code
(1)
V 50/60 Hz V DC
A
5.70…18.9
BER16-4
VEM4
1SBN081311R1000
1SBN030111R1000
BER38-4
+
VEM4
+ 2x CA4-10
1SBN082311R1000
1SBN030111R1000
1SBN010110R1010
BER65-4
+
VM96-4
+ 2x CA4-10
+ 2x CA4-01
1SBN083411R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
BER96-4
+
VM96-4
+ 2x CA4-10
+ 2x CA4-01
1SBN083911R1000
1SBN033405T1000
1SBN010110R1010
1SBN010110R1001
+
1SBL137001R1310
5.70…18.9
EF19-18.9
1SAX121001R1105
5.70…18.9
EF19-18.9
1SAX121001R1105
9.00…30.0
EF45-30
1SAX221001R1101
9.00…30.0
EF45-30
1SAX221001R1101
15.0…45.0
EF45-45
1SAX221001R1102
25.0...70.0
EF65-70
1SAX331001R1101
25.0…70.0
EF65-70
1SAX331001R1101
25.0…70.0
EF65-70
1SAX331001R1101
36…100
EF96-100
1SAX341001R1101
36…100
EF96-100
1SAX341001R1101
54…150
EF146-150
1SAX351001R1101
5
1SBL157001R1310
1SBL177001R1310
1SBL237001R1300
1SBL277001R1300
54…150
EF146-150
1SAX351001R1101
63…210
EF205-210
1SAX531001R1101
63…210
EF205-210
1SAX531001R1101
115…380
EF370-380
1SAX611001R1101
115…380
EF370-380
1SAX611001R1101
115…380
EF370-380
1SAX611001R1101
+
BER140-4 1SFN084211R1000
VM19
1SFN030300R1000
+
BER205-4 1SFN084811R1000
VM19
1SFN030300R1000
+
BER370-4 1SFN085411R1000
VM19
1SFN030300R1000
1SBC101949S0201
(1) For other control voltages, see "Voltage code table".
ABB | 5/37
DOL and reversing starters protected by overload relays
With AF contactors - Open type version in kit form
Switching frequency diagrams
General
Overload relays cannot be operated at any arbitrary switching frequency in order to avoid tripping. Applications involving up to 15 operations per
hour are acceptable. Higher switching frequencies are permitted if the duty ratio and the motor starting time are allowed for and if the motor's
making current does not appreciably exceed 6 times the rated operating current. Please refer to the adjacent diagram for guideline values for the
permitted switching frequency.
Thermal overload relay
140
Example:
120
Starting time of the motor: 1 second - Duty ratio: 40 % means a permitted
switching frequency of max. 60 operating cycles per hour.
100
ta =
0.5
80
s
ta
20
ta =
=1
s
ta =
1
ta
40
=
60
.5
3s
s
5s
0
0
20
40
60
80
100
Duty ratio (%)
ta: motor starting time
Electronic overload relay
Intermittent periodic duty
=0
.5
s
140
120
100
ta =
80
60
ta = 1
.5 s
40
0
20
ta
70
60
80
100
Duty ratio (%)
s
50
40
ta =
30
0
4s
ta = 6
s
ta = 8
s
t a = 10
s
t a = 12
s
10
40
=2
60
20
ta = 3 s
ta = 5 s
20
0
1s
80
Trip class 30E
Switching frequency (ops/h)
ta
160
Trip class 20E
Switching frequency (ops/h)
Trip class 10E
Switching frequency (ops/h)
0
20
40
50
ta
45
30
25
ta =
20
15
100
Duty ratio (%)
0
10 s
ta = 1
5s
t a = 20
s
t a = 25 s
5
80
s
35
10
60
=5
40
0
20
40
60
80
100
Duty ratio (%)
ta: motor starting time
Exemple for trip class 10E:
Starting time of the motor: 1 second. Duty ratio: 60 % means a permitted switching frequency of max. 60 operating cycles per hour, for a motor
breaking current not exceeding 6 x In.
1SBC101954S0201
5
Switching frequency (ops/h)
Intermittent periodic duty
5/38 | ABB
DOL and reversing starters protected by overload relays
With AF contactors - Open type version in kit form
Wiring diagrams
Direct-on-line starters
AC or DC remote control
KM1:5/L3
Us
KM1:5/L3
Us
96
FR1
A
M
STOP
O
13
KM1
14
97
I
M
M
5
KM1
Us
N
KM1:3/L2
KM1:3/L2
~
~
A1 14
V
KM1
Us
N
A2
4/T2
U
KM1
A1
2/T1
W
V
6/T3
6/T3
U
4/T2
2/T1
98
96
TEST
STOP
I
FR1
FR1
A2
M
13
A
95
RESET
FR1
14
6/T3
4/T2
2/T1
14
6/T3
4/T2
2/T1
RESET
95
A
M
96
13
RESET
95
5/L3
3/L2
1/L1
5/L3
13
A1
AC or DC local control
STOP
A2
KM1
3/L2
1-phase
1/L1
Power circuit
Note: coil Uc 12-20 V DC : A1+, A2-
Reversing starters
AC or DC local control
3/L2
5/L3
4/T2
6/T3
A
M
STOP
FR1
.4
21
A2
22
KM1
KM1
A1
A1
A2
A2
KM2
(3)
KM1:3/L2
AC or DC remote control
RESET
A
95
KM1:5/L3
Us
M
96
STOP
FR1
O
.3
II
.3
KM1
KM2
.4
I
A2
(1)
KM2
A2
KM1
21
KM1
A1
A1
A2
A2
KM2
1SBC101926S0201
KM1:3/L2
KM1
KM2
22
Us
N
(2)
21
With VEM4
With VM
01
01
(2)
22
~
A2
KM2
(1)
.4
M
KM1
KM2
(2)
22
Us
N
U VW
01
01
(2)
6/T3
4/T2
2/T1
98
96
With VEM4
21
With VM
FR1
TEST
STOP
KM2
II
97
95
A
M
.4
KM1
I
RESET
.3
.3
6/T3
4/T2
2/T1
A2
96
1/L1
2/T1
RESET
A1
5/L3
3/L2
KM2
A2
KM1
A1
1/L1
KM1:5/L3
Us
95
Power circuit
(3)
Note: - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection
(Except for coil Uc 12-20 V DC : use VM4 with CA4).
- coil Uc 12-20 V DC : A1+, A2-
ABB | 5/39
DOL starters protected by thermal overload relays
With AF contactors - open type version in kit form
mm, inches
5 0.20"
35
101.38"
ø0.39"
4.2 0.17"
80 3.15"
10
0.39"
5.5 0.22"
35 1.38"
2x
ø 4.2
0.17"
M4 8-32
UNC
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
5.5 0.22"
5 0.20"
9.2
0.36"
6.2
0.24"
5 0.20"
5.5 0.22"
70 2.76"
86 3.39"
80 3.15"
60 2.36"
45 1.77"
5 0.20"
70 2.76"
5.5 0.22"
45 1.77"
35 mm EN/IEC 60715
ø 4.2 0.17"
2x
M4 8-32 UNC
158.9 6.26"
35 1.38"
5 0.20"
158.9 6.26"
156.1 6.15"
35 mm EN/IEC 60715
5.5 0.22"
86 3.39"
10
0.39"
60 2.36"
71 2.80"
60 2.36"
77 3.03"
45 1.77"
35 mm EN/IEC 60715
Main dimensions
5 0.20"
9.2
0.36"
5
72.7 2.86"
75.7 2.98"
75.7 2.98"
76.8 3.02"
79.8 3.14"
79.8 3.14"
AF09, AF12, AF16
+ TF42 thermal overload relay
AF26, AF30, AF38
+ TF42 thermal overload relay
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
111 4.37"
55 2.17"
10 0.39"
116 4.57"
70 2.76"
35 x 15 mm EN/IEC 60715
5.5 0.22"
106.8 4.20"
106.8 4.20"
AF80, AF96
+ TF96 thermal overload relay
60 2.36"
2x
M6 ¼-20 UNC
ø 6.4 0.25"
2x
M6 ¼-20 UNC
5 0.20"
AF80, AF96
+ TF96 thermal overload relay
1SBC101927S0201
4.6 0.18"
110 4.33"
4.6 0.18"
5 0.20"
AF40, AF52, AF65
+ TF65 thermal overload relay
5/40 | ABB
110.9 4.37"
2x
M4 8-32 UNC
100 3.94"
110 4.33"
ø 4.2 0.17"
110.6 4.35"
100 3.94"
45 1.77"
ø 6.4 0.25"
5.5 0.22"
4 0.16"
4 0.16"
AF40, AF52, AF65
+ TF65 thermal overload relay
10 0.39"
7 0.28"
211 8.31"
208.5 8.21"
35 mm EN/IEC 60715
7 0.28"
DOL starters protected by thermal overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
126 4.96"
17 0.67"
30 1.18"
3 0.12"
4x
M4 8-32 UNC
45 1.77"
259 10.20"
100 3.94"
90 3.54"
5
82.3 3.24"
6 0.24"
4x
M5 10-24 UNC
37 1.46"
8 0.31"
50 1.97"
AF116, AF140-30-11(B)
+ TF140 thermal overload relay
AF116, AF140-30-11(B)
+ TF140 thermal overload relay
152 5.98"
105 4.13"
35.5 1.40"
5 0.20"
8x
M5 10-24 UNC
11 0.43"
21 0.83"
82 3.23"
25.5
1.0"
312.5 12.3"
165 6.50"
35 1.39"
20 0.79"
42.5 1.67"
AF190, AF205-30-11
+ TA200DU thermal overload relay
62 2.44"
4 0.16"
1SFC101156C0201
37 1.46"
ø 11 0.43"
50 1.97"
126 4.96"
AF190, AF205
+ TA200DU thermal overload relay
ABB | 5/41
Reversing starters protected by thermal overload relays
With AF contactors - open type version in kit form
mm, inches
102.5 4.04"
119.5 4.70"
90 3.54"
71 2.80"
70 2.76"
60 2.36"
5.5 0.22"
2x
M4 8-32 UNC
80 3.15"
ø 4.2 0.17"
6.2
0.24"
5 0.20"
10
0.39"
170 6.69"
166.5 6.56"
35 mm EN/IEC 60715
5.5 0.22"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
90 3.54"
5.5 0.22"
80
10
0.39"
60 2.36"
Main dimensions
ø 4.2 0.17
5 0.20"
9.2
0.36"
5
72.7 2.86"
75.7 2.98"
76.8 3.02"
AF09, AF12, AF16
+ BER16-4, VEM4
+ TF42 thermal overload relay
2x
M4 8-32 UNC
60 2.36"
70 2.76"
80 3.15"
ø 4.2 0.17"
79.8 3.14"
5 0.20"
10
0.39"
AF26, AF30, AF38
+ BER38-4, VEM4, CA4-10
+ TF42 thermal overload relay
5 0.20"
AF09, AF12, AF16, AF26, AF30, AF38
1SBC101928S0201
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/42 | ABB
Reversing starters protected by thermal overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
144 5.67"
111 4.37"
110 4.33"
10
M6 ¼-20 UNC
100 3.94"
0.39"
4.6 0.18"
5.5 0.22"
100 3.94"
110 4.33"
35 x 15 mm EN/IEC 60715
223 8.78"
M4 8-32 UNC
ø 4.2 0.17"
ø 6.4 0.25"
4 0.16"
5
5 0.20"
AF40, AF52, AF65
+ BER65-4, VM96-4
+ TF65 thermal overload relay
106.8 4.20"
110.6 4.35"
AF40, AF52, AF65
+ BER65-4, VM96-4
+ TF65 thermal overload relay
149 5.87"
140 5.51"
116 4.57"
M6 ¼-20 UNC
130 5.12"
10
4.6 0.18"
5.5 0.22"
100 3.94"
110 4.33"
35 x 15 mm EN/IEC 60715
226 8.90"
0.39"
ø 6.4 0.25"
4 0.16"
5 0.20"
AF80, AF96
+ BER96-4, VM96-4
+ TF96 thermal overload relay
106.8 4.20"
110.9 4.37"
1SBC101929S0201
AF80, AF96
+ BER96-4, VM96-4
+ TF96 thermal overload relay
ABB | 5/43
Reversing starters protected by thermal overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
180 7.09"
126 4.96"
8x
60 2.36"
30 1.18"
M4 8-32 UNC
272 10.71"
100 3.94"
30 1.18"
82.3 3.24"
45 1.77"
5
4x
M5 10-24 UNC
37 1.46"
50 1.97"
1SFC101158C0201
AF116, AF140, AF146
+ BER140-4, VM19
+ TF140 thermal overload relay
5/44 | ABB
Reversing starters protected by thermal overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
210 8.27"
152 5.98"
395 15.55"
5
35
35
12 X
M5 10-24 UNC
1.38"
1SFC101159C0201
82 3.23"
81.5 3.21"
165 6.50"
1.38"
70 2.76"
37 1.46"
50 1.97"
AF190, AF205
+ BER205-4, VM19
+ TA200DU thermal overload relay
ABB | 5/45
DOL starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
86 3.39"
77 3.03"
71 2.80"
45 1.77"
45 1.77"
10 0.39"
80 3.15"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5.5 0.22"
155.2 6.11"
152.4 6.00"
10 0.39"
5.5 0.22"
5.5 0.22"
5.5 0.22"
17.4 0.69"
20.4 0.80"
5
73.3 2.89"
76.3 3.00"
76.8 3.02"
79.8 3.14"
AF26, AF30, AF38
+ EF19 electronic overload relay
AF09, AF12, AF16
+ EF19 electronic overload relay
35 1.38"
10
0.39"
5.5 0.22"
ø 4.2 0.17"
2x
M4 8-32 UNC
70 2.76"
80 3.15"
10 0.39"
5 0.20"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
158.9 6.26"
5.5 0.22"
5.5 0.22"
60 2.36"
80 3.15"
5.5 0.22"
172.3 6.78"
86 3.39"
86 3.39"
45 1.77"
45 1.77"
5 0.20"
AF09, AF12, AF16, AF26, AF30, AF38
+ EF electronic overload relay
9.2
0.36"
75.7 2.98"
79.8 3.14"
82.5 3.25"
86 3.39"
AF26, AF30, AF38
+ EF45 electronic overload relay
1SBC101950S0201
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/46 | ABB
DOL starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
111 4.37"
55 2.17"
10 0.39"
116 4.57"
70 2.76"
35 x 15 mm EN/IEC 60715
5.5 0.22"
237 9.33"
35 mm EN/IEC 60715
237 9.33"
10 0.39"
7 0.28"
7 0.28"
5.5 0.22"
5.4 0.21"
5.4 0.21"
5
106.8 4.20"
110.6 4.35"
70 2.76"
106.8 4.20"
110.6 4.35"
AF40, AF52, AF65
+ EF65 electronic overload relay
ø 6.4 0.25"
2x
M6 ¼-20 UNC
4.6 0.18"
4.6 0.18"
110 4.33"
2x
M4 8-32 UNC
5 0.20"
AF40, AF52, AF65
+ EF65 electronic overload relay
5 0.20"
AF80, AF96
+ EF96 electronic overload relay
1SBC101951S0201
100 3.94"
110 4.33"
ø 4.2 0.17"
60 2.36"
2x
M6 ¼-20 UNC
100 3.94"
45 1.77"
ø 6.4 0.25"
AF80, AF96
+ EF96 electronic overload relay
ABB | 5/47
DOL starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
126 4.96"
17 0.67"
30 1.18"
3 0.12"
6x
M4 8-32 UNC
46 1.81"
21.5
94.7 3.73"
0.85"
105 4.13"
37 1.46"
2x
M5 10-24 UNC
AF116, AF140, AF146-30-11(B)
+ EF146 electronic overload relay
AF116, AF140, AF146-30-11(B)
+ EF146 electronic overload relay
152 5.98"
105 4.13"
8x
M5 10-24 UNC
5 0.20"
20.5
10 0.39"
112 4.42"
0.81"
165 6.50"
35.5 1.40"
342 13.46"
17.5 0.69"
35 1.38"
35 1.38"
8.5 0.33"
AF190, AF205-30-11
+ EF205 electronic overload relay
5/48 | ABB
35 1.39"
5 0.20"
123 4.84"
AF190, AF205
+ EF205 electronic overload relay
1SFC101161C0201
35 1.38"
5
270 10.63"
100 3.94"
90 3.54"
DOL starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
180 7.09"
35.5 1.40"
8x
M5 10-24 UNC
5 0.20"
187 7.36"
140 5.51"
ø 11 0.43"
44 1.73"
20 1.79"
43.8 1.72"
14 0.55"
112 4.41"
29 1.14"
385 15.16"
5
35 1.38"
43.75 1.72"
35 1.20"
5 0.20"
123 4.84"
1SFC101157C0201
AF265, AF305, AF370-30-11
+ EF370 electronic overload relay
ABB | 5/49
Reversing starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
102.5 4.04"
119.5 4.70"
90 3.54"
71 2.80"
10
0.39"
5.5 0.22"
5.5 0.22"
5.5 0.22"
166 6.54"
163 6.42"
35 mm EN/IEC 60715
80 3.15"
35 mm EN/IEC 60715
90 3.54"
10
0.39"
5.5 0.22"
20.4 0.80"
17.4 0.69"
5
73.3 2.89"
76.3 3.00"
76.8 3.02"
79.8 3.14"
AF09, AF12, AF16
+ BER16-4, VEM4
+ EF19 electronic overload relay
AF26, AF30, AF38
+ BER38-4, VEM4, CA4-10
+ EF19 electronic overload relay
119.5 4.70"
102.5 4.04"
90 3.54" 80 3.15"
71 2.80"
5.5 0.22"
ø 4.2 0.17"
6.2
0.24"
2x
M4 8-32 UNC
80 3.15"
70 2.76"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
166.5 6.56"
183.5 7.22"
5.5 0.22"
10
0.39"
5 0.20"
10 5.5 0.22"
0.39"
5.5 0.22"
60 2.36"
90 3.54"
5 0.20"
AF09, AF12, AF16, AF26, AF30, AF38
72.7 2.86"
76.8 3.02"
82.5 3.25"
86 3.39"
AF26, AF30, AF38
+ BER38-4, VEM4, CA4-10
+ EF45 electronic overload relay
1SBC101952S0201
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/50 | ABB
Reversing starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
144 5.67"
111 4.37"
117.5 4.63"
10
M6 ¼-20 UNC
100 3.94"
0.39"
100 3.94"
110 4.33"
5.5 0.22"
4.6 0.18"
251 9.88"
35 x 15 mm EN/IEC 60715
M4 8-32 UNC
ø 4.2 0.17"
5.4 0.21"
ø 6.4 0.25"
5
5 0.20"
AF40, AF52, AF65
+ BER65-4, VM96-4
+ EF65 electronic overload relay
106.8 4.20"
110.6 4.35"
AF40, AF52, AF65
+ BER65-4, VM96-4
+ EF65 electronic overload relay
149 5.87"
140 5.51"
116 4.57"
M6 ¼-20 UNC
130 5.12"
10
4.6 0.18"
5.5 0.22"
100 3.94"
110 4.33"
35 x 15 mm EN/IEC 60715
251 9.88"
0.39"
5.4 0.21"
ø 6.4 0.25"
5 0.20"
AF80, AF96
+ BER96-4, VM96-4
+ EF96 electronic overload relay
106.8 4.20"
110.6 4.35"
1SBC101953S0201
AF80, AF96
+ BER96-4, VM96-4
+ EF96 electronic overload relay
ABB | 5/51
Reversing starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
180 7.09"
126 4.96"
60 2.36"
30 1.18"
10x
M4 8-32 UNC
5
43.8 1.72"
281.5 11.08"
100 3.94"
30 1.18"
21.5
94.7 3.73"
0.85"
2x
M5 10-24 UNC
37 1.46"
1SFC101162C0201
AF116, AF140, AF146
+ BER140-4, VM19
+ EF146 electronic overload relay
5/52 | ABB
Reversing starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
210 8.27"
152 5.98"
425 16.73"
5
35
70 2.76"
35
12 X
M5 10-24 UNC
1.38"
1SFC101163C0201
112 4.42"
76 2.99"
165 6.50"
1.38"
AF190, AF205
+ BER205-4, VM19
+ EF205 electronic overload relay
ABB | 5/53
Reversing starters protected by electronic overload relays
With AF contactors - open type version in kit form
Main dimensions
mm, inches
280 11.02"
180 7.09"
477.5 18.80"
5
43.75
96.25 3.79"
12 X
M5 10-24 UNC
1.72"
AF265, AF305, AF370
+ BER370-4, VM19
+ EF370 electronic overload relay
5/54 | ABB
35
1.38"
1SFC101160C0201
112 4.41"
90.5 3.56"
187 7.36"
1.72"
43.75
Notes
N2
5
ABB | 5/55
Star-delta starters protected by overload relays
With AF contactors - Open type version in kit form
Application
L Δ
Star-delta starting is the most common method to reduce the starting current of a motor.
Y
This system can be used on all the squirrel cage motors, which are normally used in delta connection. In this
type of starting, it is recommended to choose motors having high starting torque i.e. much higher than the
resistive torque in order to reach sufficient high speed when the motor is connected in star.
When starting:
I/In T/T
n
7
1SFC101103V0001
6
5
–– Inrush current is reduced to a third of direct starting
current
–– Motor torque is reduced to a third or even less of direct
starting torque.
I (delta)
5
Transient current is generated when switching from star to
delta connection.
4
During the initial starting phase ("star" connection), the
resistive torque of the driven load must remain, irrespective
of speed, less than the "star" motor torque until "star-delta"
switching occurs.
3
T∆ (motor)
I (star)
2
1
AF16-30-10 + AF16-30-10 +
AF09-30-10 + BEY16-4 + VEM4 +
TF42
This starting mode is therefore ideal for machines having
low starting torque such as pumps, centrifugal compressors, wood-working machines...
T
(motor)
Tr (resistive torque)
0
20
40
60
80
100
Motor speed (%)
1SFC101104V0001
I = current
T = torque
In = nominal current
Tn = nominal torque
Precaution
–– Motor nominal voltage in delta connection must be equal to that of the mains. Example: a motor for 400 V
star-delta starting must be designed for 400 V in "delta" connection. Its usual designation is "400 V /
690 V motor". The motor must be constructed with 6 terminal windings
–– In order to prevent a high current peak, at least 85 % of nominal speed must be reached before switching
from star to delta
Sequence
AF140-30-11 + AF140-30-11 +
AF140-30-11 + BEY140-4 + VM19
+ EF146
Starting is a three-stage process:
1st stage: "Star" connection - Press the "On" button on the control circuit to close the KM2 "Star" contactor.
The KM1 "line" contactor then closes and the motor starts. Countdown of programmed starting time (6 to
10 s) then begins.
2nd stage: "Star" to "Delta" switching - when programmed starting time is over, the KM2 "Star" contactor opens.
3rd stage: "Delta" connection - Thanks to AF contactors, a transition time (or dwelling time) of 50 ms is
already integrated between the opening of the "star" contactor and closing of the "delta" contactor.
Conclusion: An on-delay timer without dwelling time (e.g.: CT-ERS.21S or TEF4-ON) is enough to countdown the programmed starting time (6 to 10 s) during "Star connection". The use of a star-delta timer including a dwelling time is not permitted.
Main Technical Data
Mounting positions
Standards
IEC 60947-4-1 / EN 60947-4-1
Rated operational voltage Ue max.
690 V - 50/60 Hz
Rated insulation voltage Ui
acc. to IEC 60947-4-1
690 V
acc. to UL / CSA
600 V
Ambient air temperature
Pos. 1
5/56 | ABB
≤ 60 °C (TF42: 38 A above ≤ 50 °C)
IP20
Switching frequency
Refer to "Switching frequency diagrams" page
1SBC101956S0201
Close to the device
Degree of protection
Star-delta starters protected by overload relays
With AF contactors - Open type version in kit form
Description
Star-delta starters for AF09 ... AF38
L Δ
Y
A2
A2
Fixing
clip
2
KM
3
1
KM
KM
AF09 ... AF38
Contactors
VM4
Mechanical
interlock
unit
VE4
Electrical
interlock block
You can easily assemble star-delta starter
thanks to our complete range of accessories:
–– For AF09 ... AF38, use VEM4 mechanical and electrical interlock set without
increasing starter width. It includes:
-- VM4 mechanical interlock unit and 2
fixing clips
-- VE4 electrical interlock block with
A2-A2 connection.
–– For AF40 ... AF370, use VM mechanical interlock unit and additional auxiliary
contact blocks for electrical interlocking.
–– BEY..-4 connection set: it assures a
safe and simple connection between
both contactor main terminals.
5
Select now easily and quickly your
starter in the following pages at 400 V,
up to 200 kW.
BEY..-4
Connection set
For the full coordination tables:
www.abb.com/lowvoltage then go to the right
menu: "Support", select: "Online Product Selection
Tools" then select "Coordination Tables for motor
protection"
TF42
Thermal overload relay
EF19, EF45
Electronic overload relay
Star-delta starters for AF116 ... AF370
BEY..-4
Connection set
2
KM
BEY..-4
Connection set
3
KM
AF contactor
with built-in
cable clamps
VM
Mechanical
interlock
unit
1
KM
AF contactor
with built-in
cable clamps
BEY..-4
Connection set
TF/TA
Thermal overload relay
EF
Electronic overload relay
1SBC101956S0201
L Δ
Y
ABB | 5/57
Star-delta starters protected by thermal overload relays
With AF contactors - Open type version in kit form
L Δ
Line contactor KM1
Delta contactor KM3
Star contactor KM2
Control voltage
Uc min. ... Uc max.
(1)
Type
Type
Type
Order code
24...60
AF09Z-30-10-21 1SBL136001R2110
AF09Z-30-10-21 1SBL136001R2110
AF09Z-30-10-21
1SBL136001R2110
AF09-30-10-13
AF09-30-10-13
1SBL137001R1310
AF12Z-30-10-21 1SBL156001R2110
AF09Z-30-10-21
1SBL136001R2110
AF12-30-10-13
AF09-30-10-13
1SBL137001R1310
AF16Z-30-10-21 1SBL176001R2110
AF09Z-30-10-21
1SBL136001R2110
AF16-30-10-13
AF09-30-10-13
1SBL137001R1310
AF26Z-30-00-21 1SBL236001R2100
AF26Z-30-00-21
1SBL236001R2100
AF26-30-00-13
AF26-30-00-13
1SBL237001R1300
AF26Z-30-00-21 1SBL236001R2100
AF26Z-30-00-21
1SBL236001R2100
AF26-30-00-13
AF26-30-00-13
1SBL237001R1300
AF30Z-30-00-21 1SBL276001R2100
AF26Z-30-00-21
1SBL236001R2100
Y
IEC
AC-3
Rated power
Order code
Order code
Rated
current
220 V 230/240 V 380 V 400 V 415 V 440 V 500 V 690 V 400 V
kW kW
kW kW kW kW kW kW A
V 50/60 Hz V DC
5
4
4
7.5
7.5
7.5
7.5
9
9
15.5
20...60
100...250 100...250 AF09-30-10-13
5.5
5.5
9
11
11
11
11
11
22
24...60
20...60
AF12Z-30-10-21 1SBL156001R2110
100...250 100...250 AF12-30-10-13
7.5
9
15
15
15
15
15
15
29
24...60
20...60
11
18.5 18.5 25
25
25
25
35
24...60
20...60
11
22
22
25
25
25
25
41
24...60
20...60
15
18.5 18.5
25
30
37
45
55
75
90
25
30
37
45
55
75
90
25
37
45
55
75
90
90
132
160
25
37
45
55
75
90
110
132
160
25
37
45
55
75
90
110
132
160
25
37
45
55
75
90
132
132
160
30
37
45
55
75
90
132
160
200
30
37
45
55
75
90
110
132
200
47
66
80
97
132
160
195
230
280
24...60
20...60
1SBL237001R1300
AF26Z-30-00-21 1SBL236001R2100
100...250 100...250 AF26-30-00-13
11
1SBL177001R1310
AF26Z-30-00-21 1SBL236001R2100
100...250 100...250 AF26-30-00-13
11
1SBL157001R1310
AF16Z-30-10-21 1SBL176001R2110
100...250 100...250 AF16-30-10-13
11
1SBL137001R1310
1SBL237001R1300
AF30Z-30-00-21 1SBL276001R2100
1SBL137001R1310
1SBL157001R1310
1SBL177001R1310
1SBL237001R1300
1SBL237001R1300
100...250 100...250 AF30-30-00-13
1SBL277001R1300
AF30-30-00-13
1SBL277001R1300
AF26-30-00-13
1SBL237001R1300
24...60
AF40-30-00-11
1SBL347001R1100
AF40-30-00-11
1SBL347001R1100
AF40-30-00-11
1SBL347001R1100
100...250 100...250 AF40-30-00-13
1SBL347001R1300
AF40-30-00-13
1SBL347001R1300
AF40-30-00-13
1SBL347001R1300
24...60
20...60
AF52-30-00-11
1SBL367001R1100
AF52-30-00-11
1SBL367001R1100
AF40-30-00-11
1SBL347001R1100
100...250 100...250 AF52-30-00-13
20...60
1SBL367001R1300
AF52-30-00-13
1SBL367001R1300
AF40-30-00-13
1SBL347001R1300
24...60
AF65-30-00-11
1SBL387001R1100
AF65-30-00-11
1SBL387001R1100
AF40-30-00-11
1SBL347001R1100
100...250 100...250 AF65-30-00-13
20...60
1SBL387001R1300
AF65-30-00-13
1SBL387001R1300
AF40-30-00-13
1SBL347001R1300
24...60
AF80-30-00-11
1SBL397001R1100
AF80-30-00-11
1SBL397001R1100
AF52-30-00-11
1SBL367001R1100
100...250 100...250 AF80-30-00-13
1SBL397001R1300
AF80-30-00-13
1SBL397001R1300
AF52-30-00-13
1SBL367001R1300
24...60
AF96-30-00-11
1SBL407001R1100
AF96-30-00-11
1SBL407001R1100
AF65-30-00-11
1SBL387001R1100
100...250 100...250 AF96-30-00-13
1SBL407001R1300
AF96-30-00-13
1SBL407001R1300
AF65-30-00-13
1SBL387001R1300
24...60
20...60
20...60
AF116-30-11-11 1SFL427001R1111
AF116-30-11-11 1SFL427001R1111
AF116-30-11-11 (4) 1SFL427001R1111
100...250 100...250 AF116-30-11-13 1SFL427001R1311
20...60
AF116-30-11-13 1SFL427001R1311
AF116-30-11-13
1SFL427001R1311
24...60
AF140-30-11-11 1SFL447001R1111
AF140-30-11-11 1SFL447001R1111
AF116-30-11-11
1SFL427001R1111
100...250 100...250 AF140-30-11-13 1SFL447001R1311
AF140-30-11-13 1SFL447001R1311
AF116-30-11-13
1SFL427001R1311
24...60
AF190-30-11-11 1SFL487002R1111
AF190-30-11-11 1SFL487002R1111
AF140-30-11-11
1SFL447001R1111
100...250 100...250 AF190-30-11-13 1SFL487002R1311
AF190-30-11-13 1SFL487002R1311
AF140-30-11-13
1SFL447001R1311
20...60
20...60
(1) AF09 ... AF190: ambient temperature ≤ 60 °C.
(2) The setting current value is: nominal motor current x 0.58. Overload relay type given for 400 V - AC-3.
For other voltage, select overload relay type according to required nominal motor current x 0.58.
(3) On-delay timer without dwelling-time (e.g.: side-mounted CT-ERS.21S or front-mounted TEF4-ON) is enough to countdown the programmed starting time during "Star connection".
In case of use of front-mounted TEF4-ON on-delay timer, mount on KM1 contactor AF26 ... AF96 a side-mounted CAL4-11 auxiliary contact block instead of CA4-10 auxiliary contact block.
(4) AF80 can also be used, but no connection set and mechanical interlock is available for this combination.
5/58 | ABB
Thermal overload relays (2)
Electronic timers (3)
Accessories
Auxiliary contact blocks
Connection
sets
BEY..-4
CT-ERS
Setting
ranges
TEF4-ON
Uc = 24...240 V
50/60 Hz or DC
Mechanical
and electrical
interlock sets
CA4
VEM4
Type
Order code
Type
Order code
Type
Order code
Type
Order code
7.60...10.0
TF42-10
1SAZ721201R1043
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY16-4
+ VEM4
1SBN081313R2000
1SBN030111R1000
-
-
10.0...13.0
TF42-13
1SAZ721201R1045
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY16-4
+ VEM4
1SBN081313R2000
1SBN030111R1000
-
-
16.0...20.0
TF42-20
1SAZ721201R1049
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY16-4
+ VEM4
1SBN081313R2000
1SBN030111R1000
-
-
20.0...24.0
TF42-24
1SAZ721201R1051
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY38-4
+ VEM4
1SBN082713R2000
1SBN030111R1000
KM1 : 1 x CA4-10
KM2 : 1 x CA4-10
1SBN010110R1010
1SBN010110R1010
20.0...24.0
TF42-24
1SAZ721201R1051
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY38-4
+ VEM4
1SBN082713R2000
1SBN030111R1000
KM1 : 1 x CA4-10
KM2 : 1 x CA4-10
1SBN010110R1010
1SBN010110R1010
24.0...29.0
TF42-29
1SAZ721201R1052
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY38-4
+ VEM4
1SBN082713R2000
1SBN030111R1000
KM1 : 1 x CA4-10
KM2 : 1 x CA4-10
1SBN010110R1010
1SBN010110R1010
30.0...40.0
TF65-40
1SAZ811201R1003
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY65-4
+ VM96-4
1SBN083413R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
36.0...47.0
TF65-47
1SAZ811201R1004
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY65-4
+ VM96-4
1SBN083413R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
50.0...60.0
TF65-60
1SAZ811201R1006
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY65-4
+ VM96-4
1SBN083413R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
65.0...78.0
TF96-78
1SAZ911201R1004
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY96-4
+ VM96-4
1SBN083913R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
84.0...96.0
TF96-96
1SAZ911201R1006
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY96-4
+ VM96-4
1SBN083913R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
100...135
TF140DU-135
1SAZ431201R1003
CT-ERS.21S
1SVR730100R0300
BEY140-4
+ VM19
1SFN084413R1000
1SFN030300R1000
-
-
100...135
TF140DU-135
1SAZ431201R1003
CT-ERS.21S
1SVR730100R0300
BEY140-4
+ VM19
1SFN084413R1000
1SFN030300R1000
-
-
130...175
TA200DU-175
1SAZ421201R1005
CT-ERS.21S
1SVR730100R0300
BEY190-4
+ VM140/190
1SFN084813R1000
1SFN034403R1000
-
-
A
1SBC101959S0201
5
ABB | 5/59
Star-delta starters protected by electronic overload relays
With AF contactors - Open type version in kit form
L Δ
Line contactor KM1
Delta contactor KM3
Star contactor KM2
Control voltage
Uc min. ... Uc max.
(1)
Type
Type
Type
Order code
24...60
AF09Z-30-10-21 1SBL136001R2110
AF09Z-30-10-21 1SBL136001R2110
AF09Z-30-10-21
1SBL136001R2110
AF09-30-10-13
AF09-30-10-13
1SBL137001R1310
AF12Z-30-10-21 1SBL156001R2110
AF09Z-30-10-21
1SBL136001R2110
AF12-30-10-13
AF09-30-10-13
1SBL137001R1310
AF16Z-30-10-21 1SBL176001R2110
AF09Z-30-10-21
1SBL136001R2110
AF16-30-10-13
AF09-30-10-13
1SBL137001R1310
AF26Z-30-00-21 1SBL236001R2100
AF26Z-30-00-21
1SBL236001R2100
AF26-30-00-13
AF26-30-00-13
1SBL237001R1300
AF26Z-30-00-21 1SBL236001R2100
AF26Z-30-00-21
1SBL236001R2100
AF26-30-00-13
AF26-30-00-13
1SBL237001R1300
AF30Z-30-00-21 1SBL276001R2100
AF26Z-30-00-21
1SBL236001R2100
Y
IEC
AC-3
Rated power
Order code
Order code
Rated
current
220 V 230/240 V 380 V 400 V 415 V 440 V 500 V 690 V 400 V
kW kW
kW kW kW kW kW kW A
V 50/60 Hz V DC
5
4
4
7.5
7.5
7.5
7.5
9
9
15.5
20...60
100...250 100...250 AF09-30-10-13
5.5
5.5
9
11
11
11
11
11
22
24...60
20...60
AF12Z-30-10-21 1SBL156001R2110
100...250 100...250 AF12-30-10-13
7.5
9
15
15
15
15
15
15
29
24...60
20...60
11
18.5 18.5 25
25
25
25
35
24...60
20...60
11
22
22
25
25
25
25
41
24...60
20...60
15
18.5 18.5
25
30
37
45
55
75
90
110
132
160
200
25
30
37
45
55
75
90
110
132
160
200
25
37
45
55
75
90
90
132
160
160
250
315
315
25
37
45
55
75
90
110
132
160
200
250
315
355
25
37
45
55
75
90
110
132
160
200
250
315
355
25
37
45
55
75
90
132
132
160
200
250
355
400
30
37
45
55
75
90
132
160
200
250
315
400
400
30
37
45
55
75
90
110
132
200
250
355
400
500
47
66
80
97
132
160
195
230
280
350
430
540
610
24...60
20...60
1SBL237001R1300
AF26Z-30-00-21 1SBL236001R2100
100...250 100...250 AF26-30-00-13
11
1SBL177001R1310
AF26Z-30-00-21 1SBL236001R2100
100...250 100...250 AF26-30-00-13
11
1SBL157001R1310
AF16Z-30-10-21 1SBL176001R2110
100...250 100...250 AF16-30-10-13
11
1SBL137001R1310
1SBL237001R1300
AF30Z-30-00-21 1SBL276001R2100
1SBL137001R1310
1SBL157001R1310
1SBL177001R1310
1SBL237001R1300
1SBL237001R1300
100...250 100...250 AF30-30-00-13
1SBL277001R1300
AF30-30-00-13
1SBL277001R1300
AF26-30-00-13
1SBL237001R1300
24...60
AF40-30-00-11
1SBL347001R1100
AF40-30-00-11
1SBL347001R1100
AF40-30-00-11
1SBL347001R1100
100...250 100...250 AF40-30-00-13
1SBL347001R1300
AF40-30-00-13
1SBL347001R1300
AF40-30-00-13
1SBL347001R1300
24...60
20...60
AF52-30-00-11
1SBL367001R1100
AF52-30-00-11
1SBL367001R1100
AF40-30-00-11
1SBL347001R1100
100...250 100...250 AF52-30-00-13
20...60
1SBL367001R1300
AF52-30-00-13
1SBL367001R1300
AF40-30-00-13
1SBL347001R1300
24...60
AF65-30-00-11
1SBL387001R1100
AF65-30-00-11
1SBL387001R1100
AF40-30-00-11
1SBL347001R1100
100...250 100...250 AF65-30-00-13
20...60
1SBL387001R1300
AF65-30-00-13
1SBL387001R1300
AF40-30-00-13
1SBL347001R1300
24...60
AF80-30-00-11
1SBL397001R1100
AF80-30-00-11
1SBL397001R1100
AF52-30-00-11
1SBL367001R1100
100...250 100...250 AF80-30-00-13
1SBL397001R1300
AF80-30-00-13
1SBL397001R1300
AF52-30-00-13
1SBL367001R1300
24...60
AF96-30-00-11
1SBL407001R1100
AF96-30-00-11
1SBL407001R1100
AF65-30-00-11
1SBL387001R1100
100...250 100...250 AF96-30-00-13
1SBL407001R1300
AF96-30-00-13
1SBL407001R1300
AF65-30-00-13
1SBL387001R1300
24...60
20...60
20...60
AF116-30-11-11 1SFL427001R1111
AF116-30-11-11 1SFL427001R1111
AF116-30-11-11 (4) 1SFL427001R1111
100...250 100...250 AF116-30-11-13 1SFL427001R1311
20...60
AF116-30-11-13 1SFL427001R1311
AF116-30-11-13
1SFL427001R1311
24...60
AF140-30-11-11 1SFL447001R1111
AF140-30-11-11 1SFL447001R1111
AF116-30-11-11
1SFL427001R1111
100...250 100...250 AF140-30-11-13 1SFL447001R1311
AF140-30-11-13 1SFL447001R1311
AF116-30-11-13
1SFL427001R1311
24...60
AF190-30-11-11 1SFL487002R1111
AF190-30-11-11 1SFL487002R1111
AF140-30-11-11
1SFL447001R1111
100...250 100...250 AF190-30-11-13 1SFL487002R1311
AF190-30-11-13 1SFL487002R1311
AF140-30-11-13
1SFL447001R1311
24...60
AF205-30-11-11 1SFL527002R1111
AF205-30-11-11 1SFL527002R1111
AF190-30-11-11
1SFL487002R1111
100...250 100...250 AF205-30-11-13 1SFL527002R1311
AF205-30-11-13 1SFL527002R1311
AF190-30-11-13
1SFL487002R1311
24...60
AF265-30-11-11 1SFL547002R1111
AF265-30-11-11 1SFL547002R1111
AF205-30-11-11
1SFL527002R1111
100...250 100...250 AF265-30-11-13 1SFL547002R1311
AF265-30-11-13 1SFL547002R1311
AF205-30-11-13
1SFL527002R1311
24...60
AF370-30-11-11 1SFL607002R1111
AF370-30-11-11 1SFL607002R1111
AF265-30-11-11
1SFL547002R1111
100...250 100...250 AF370-30-11-13 1SFL607002R1311
AF370-30-11-13 1SFL607002R1311
AF265-30-11-13
1SFL547002R1311
24...60
AF370-30-11-11 1SFL607002R1111
AF370-30-11-11 1SFL607002R1111
AF305-30-11-11
1SFL587002R1111
100...250 100...250 AF370-30-11-13 1SFL607002R1311
AF370-30-11-13 1SFL607002R1311
AF305-30-11-13
1SFL587002R1311
20...60
20...60
20...60
20...60
20...60
20...60
(1) AF09 ... AF370: ambient temperature ≤ 60 °C.
(2) The setting current value is: nominal motor current x 0.58. Overload relay type given for 400 V - AC-3.
For other voltage, select overload relay type according to required nominal motor current x 0.58.
(3) On-delay timer without dwelling-time (e.g.: side-mounted CT-ERS.21S or front-mounted TEF4-ON) is enough to countdown the programmed starting time during "Star connection".
In case of use of front-mounted TEF4-ON on-delay timer, mount on KM1 contactor AF26 ... AF96 a side-mounted CAL4-11 auxiliary contact block instead of CA4-10 auxiliary contact block.
(4) AF80 can also be used, but no connection set and mechanical interlock is available for this combination.
5/60 | ABB
Electronic overload relays (2)
Electronic timers (3)
Accessories
Auxiliary contact blocks
Connection
sets
BEY..-4
CT-ERS
Setting
ranges
TEF4-ON
Uc = 24...240 V
50/60 Hz or DC
Mechanical
and electrical
interlock sets
CA4
VEM4
Type
Order code
Type
Order code
Type
Order code
Type
Order code
5.70…18.9
EF19-18.9
1SAX121001R1105
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY16-4
+ VEM4
1SBN081313R2000
1SBN030111R1000
-
-
5.70…18.9
EF19-18.9
1SAX121001R1105
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY16-4
+ VEM4
1SBN081313R2000
1SBN030111R1000
-
-
5.70…18.9
EF19-18.9
1SAX121001R1105
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY16-4
+ VEM4
1SBN081313R2000
1SBN030111R1000
-
-
9.00…30.0
EF45-30
1SAX221001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY38-4
+ VEM4
1SBN082713R2000
1SBN030111R1000
KM1 : 1 x CA4-10
KM2 : 1 x CA4-10
1SBN010110R1010
1SBN010110R1010
9.00…30.0
EF45-30
1SAX221001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY38-4
+ VEM4
1SBN082713R2000
1SBN030111R1000
KM1 : 1 x CA4-10
KM2 : 1 x CA4-10
1SBN010110R1010
1SBN010110R1010
9.00…30.0
EF45-30
1SAX221001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY38-4
+ VEM4
1SBN082713R2000
1SBN030111R1000
KM1 : 1 x CA4-10
KM2 : 1 x CA4-10
1SBN010110R1010
1SBN010110R1010
25…70
EF65-70
1SAX331001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY65-4
+ VM96-4
1SBN083413R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
25…70
EF65-70
1SAX331001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY65-4
+ VM96-4
1SBN083413R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
25…70
EF65-70
1SAX331001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY65-4
+ VM96-4
1SBN083413R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
36…100
EF96-100
1SAX341001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY96-4
+ VM96-4
1SBN083913R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
36…100
EF96-100
1SAX341001R1101
CT-ERS.21S
or TEF4-ON
1SVR730100R0300
1SBN020112R1000
BEY96-4
+ VM96-4
1SBN083913R2000
1SBN033405T1000
KM1 : 1 x CA4-10 (3)
KM2 : 1 x CA4-10
1 x CA4-01
KM3 : 1 x CA4-01
1SBN010110R1010
1SBN010110R1010
1SBN010110R1001
1SBN010110R1001
54…150
EF146-150
1SAX351001R1101
CT-ERS.21S
1SVR730100R0300
BEY140-4
+ VM19
1SFN084413R1000
1SFN030300R1000
-
-
54…150
EF146-150
1SAX351001R1101
CT-ERS.21S
1SVR730100R0300
BEY140-4
+ VM19
1SFN084413R1000
1SFN030300R1000
-
-
63…210
EF205-210
1SAX531001R1101
CT-ERS.21S
1SVR730100R0300
BEY190-4
+ VM140/190
1SFN084813R1000
1SFN034403R1000
-
-
63…210
EF205-210
1SAX531001R1101
CT-ERS.21S
1SVR730100R0300
BEY205-4
+ VM19
1SFN085213R1000
1SFN030300R1000
-
-
115…380
EF370-380
1SAX611001R1101
CT-ERS.21S
1SVR730100R0300
BEY265-4
+ VM205/265
1SFN085413R1000
1SFN035203R1000
-
-
115…380
EF370-380
1SAX611001R1101
CT-ERS.21S
1SVR730100R0300
BEY370-4
+ VM19
1SFN085813R1000
1SFN030300R1000
-
-
115…380
EF370-380
1SAX611001R1101
CT-ERS.21S
1SVR730100R0300
BEY370-4
+ VM19
1SFN085813R1000
1SFN030300R1000
-
-
A
1SBC101960S0201
5
ABB | 5/61
Star-delta starters protected by overload relays
With AF contactors - Open type version in kit form
Switching frequency diagrams
General
Switching frequency/hour, according to acceleration time and load factor. Respect of the following conditions enables utilization of the starter
without excessive overheating of the connections or nuisance tripping of the thermal overload relay.
Thermal overload relay
Example:
70
60
ta =
Starting time of the motor: 7 second (use 8s curve) - Duty ratio: 63 % means
a permitted switching frequency of max. 15 operating cycles per hour.
5s
50
40
ta =
ta =
30
This corresponds to a 4 minute operating cycle (15 starts/hr) with 7 seconds
acceleration, 2.5 minutes operation and 1.5 minutes rest.
8s
10 s
ta = 1
2s
20
ta = 15
s
ta = 20 s
10
0
0
10
20
30
40
50
60
70
80
90
100
Duty ratio (%)
ta: motor starting time
Electronic overload relay : please consult us
1SBC101958S0201
5
Switching frequency (ops/h)
Intermittent periodic duty
5/62 | ABB
Star-delta starters protected by overload relays
With AF contactors - Open type version in kit form
Wiring diagrams with CT-ERS.21S timer
Star-delta starters
Power circuit
AC or DC local control with CT-ERS.21S timer
KM3:5/L3
Us
A
95
RESET
M
96
5/L3
3/L2
1/L1
I
.4
6/T3
4/T2
.3
A2
2/T1
KM1
.3
W1
V1
U1
W2
V2
U2
W1
V1
U1
W2
V2
U2
KM1
KM3
A2
A2
CT-ERS.21S
KM2
(2)
(1)
A2
A2
5
With VM
KM3
KM2
21
16
01
01
(2)
A1
A1
KM3
22
With
VEM4
15
21
6/T3
A1
A1
A2
A2
KM2
Us
N
KM3:3/L2
L
(3)
∆
Y
AC or DC remote control with CT-ERS.21S timer
KM3:5/L3
Us
A
95
RESET
M
96
STOP
FR1
.3
0
KM1
I
.3
.4
KM3
A2
A2
(2)
A2
(1)
A2
CT-ERS.21S
With VM
KM2
KM2
KM3
21
16
01
01
(2)
A1
A1
KM3
22
KM1
15
21
With
VEM4
KT1
22
KM2
.4
A1
A1
A2
A2
KM2
Us
N
KM3:3/L2
L
∆
(3)
Y
Note: - VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection
(Except for coil Uc 12-20 V DC : use VM4 with CA4).
- coil Uc 12-20 V DC : A1+, A2-
1SBC101957S0201
4/T2
2/T1
98
96
KT1
22
.4
97
KM2
FR1
TEST
STOP
FR1
A1
3/L2
1/L1
5/L3
6/T3
4/T2
2/T1
6/T3
4/T2
2/T1
A2
KM2
A
M
95
RESET
A1
5/L3
3/L2
KM3
A2
KM1
A1
1/L1
STOP
ABB | 5/63
Star-delta starters protected by overload relays
With AF contactors - Open type version in kit form
Wiring diagrams with TEF4-ON timer
Star-delta starters
AC or DC local control with TEF4-ON timer
Uc = 24...240 V 50/60 Hz or DC
KM3:5/L3
95
RESET A
M
Us
96
Power circuit
5/L3
3/L2
1/L1
I
.4
6/T3
4/T2
2/T1
A2
6/T3
4/T2
2/T1
A2
6/T3
KM1
.3
A
KM2
97
6/T3
KT1 55
A1
A2
A1
KM1
With VM
01
(2)
A2
01
(2)
KM2
21
W2
V2
U2
KM3
22
TEF4-ON
W1
V1
U1
56
With
VEM4
21
4/T2
2/T1
98
TEST
STOP
.4
FR1
22
M
95
RESET
96
A1
W1
V1
U1
W2
V2
U2
KM3
Us
N
KM3:3/L2
(1)
A2
L
∆
A2
KM2
KM3
A2
A1
(1)
A2
KM2
Y
(3)
AC or DC remote control with TEF4-ON timer
Uc = 24...240 V 50/60 Hz or DC
KM3:5/L3
96
95
RESET A
M
Us
STOP
FR1
.3
O
KM1
I
I
.3
.4
KM2
.4
KT1 55
KM1
A2
01
(2)
KM2
21
With VM
01
(2)
KM3
22
A2
A1
21
TEF4-ON
A1
56
With
VEM4
22
A1
KM3
Us
N
KM3:3/L2
L
A2
∆
(1)
(3)
A2
KM2
KM3
A2
A1
(1)
A2
KM2
Y
Note: VEM4 = VM4 (1) + VE4 (2) with A2-A2 (3) connection
1SBC101962S0201
5
4/T2
2/T1
A2
.3
KM2
FR1
A1
5/L3
3/L2
1/L1
5/L3
3/L2
KM3
A1
KM1
A1
1/L1
STOP
5/64 | ABB
Star-delta starters protected by thermal overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
102.5 4.04"
71 2.80"
10
0.39"
125 4.92"
4x
M4 8-32 UNC
70 2.76"
60 2.36"
5.5 0.22"
166.5 6.55"
35 mm EN/IEC 60715
35 1.38"
5 0.20"
135 5.31"
5 0.20"
ø 4.2 0.17"
6.2
0.24"
5
AF09, AF12, AF16
+ BEY16-4, VEM4
+ TF42 thermal overload relay
72.7 2.86"
76.8 3.02"
119.5 4.70"
80 3.15"
10
0.39"
2x
M4 8-32 UNC
171 6.73"
70 2.76"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
125 4.92"
ø 4.2 0.17"
5 0.20"
135 5.31"
5 0.20"
9.2 0.36"
AF26, AF30, AF38
+ BEY38-4, VEM4, CA4-10
+ TF42 thermal overload relay
125 4.92"
79.8 3.14"
4x
M4 8-32 UNC
ø 4.2 0.17"
1SBC101963S0201
60 2.36"
70 2.76"
35 1.38"
5 0.20"
10
0.39"
75.7 2.98"
5 0.20"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/65
Star-delta starters protected by thermal overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
144 5.67"
111 4.37"
223 8.78"
35 x 15 mm EN/IEC 60715
165 6.50"
5
10
0.39"
5.5 0.22"
4 0.16"
106.8 4.20"
AF40, AF52, AF65
+ BEY65-4, VM96-4, CA4-10, CA4-01
+ TF65 thermal overload relay
110.6 4.35"
155 6.10"
M6 ¼-20 UNC
45 1.78"
4.6 0.18"
100 3.94"
110 4.33"
M4 8-32 UNC
ø 4.2 0.17"
5 0.20"
1SBC101964S0201
ø 6.4 0.25"
5/66 | ABB
Star-delta starters protected by thermal overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
149 5.87"
195 7.68"
226 8.90"
35 x 15 mm EN/IEC 60715
116 4.57"
10
0.39"
5.5 0.22"
5
4 0.16"
106.8 4.20"
Line, Delta: AF80, AF96
+ Star: AF52, AF65
+ BEY96-4, VM96-4, CA4-10, CA4-01
+ TF96 thermal overload relay
110.9 4.37"
185 7.28"
45 1.77"
60 2.36"
2x
M4 8-32 UNC
ø 4.2 0.17"
ø 6.4 0.25"
ø 6.4 0.25"
4.8 0.19"
100 3.94"
M6 ¼-20 UNC
5 0.20"
70 2.76"
1SBC101965S0201
110 4.33"
2x
M6 ¼-20 UNC
ABB | 5/67
Star-delta starters protected by thermal overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
270 10.63"
272 10.71"
126 4.96"
5
AF116, AF140, AF146
+ BEY140-4, VM19
+ TF140 thermal overload relay
60 2.36"
30 1.18"
60 2.36"
30 1.18"
12 x
M4 8-32 UNC
45 1.77"
100 3.94"
30 1.18"
82.3 3.24"
4x
M5 10-24 UNC
37 1.46"
1SFC101170C0201
50 1.97"
5/68 | ABB
Star-delta starters protected by thermal overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
152 5.98"
339 13.35"
310 12.20"
5
62 2.44"
Line, Delta: AF190, AF205
+ Star: AF116, AF140, AF146
+ BEY190-4, VM140/190
+ TA200 thermal overload relay
12 x
M5 10-24 UNC
35
70 2.76"
35
1.38"
75 2.95"
30
4x
M4 8-32 UNC
1.18"
82 3.23"
25.5
1.00"
100 3.94"
165 6.50"
1.38"
4 0.16"
126 4.96"
37 1.46"
1SFC101171C0201
50 1.97"
ABB | 5/69
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
102.5 4.04"
71 2.80"
10
0.39"
5.5 0.22"
163 6.42"
35 mm EN/IEC 60715
135 5.31"
17.4 0.69"
5
73.3 2.89"
AF09, AF12, AF16
+ BEY16-4, VEM4
+ EF19 electronic overload relay
76.8 3.02"
119.5 4.70"
135 5.31"
10
0.39"
5.5 0.22"
D
35 mm EN/IEC 60715
80 3.15"
A
B
A
B
C
D
EF19
20.4 0.80"
76.3 3.00"
79.8 3.14"
165.9 6.53"
EF45
0 0.00"
82.5 3.25"
86 3.39"
183.5 7.22"
C
AF26, AF30, AF38
+ BEY38-4, VEM4, CA4-10
+ EF19/EF45 electronic overload relay
125 4.92"
4x
M4 8-32 UNC
ø 4.2 0.17"
5 0.20"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/70 | ABB
1SBC101966S0201
60 2.36"
70 2.76"
35 1.38"
5 0.20"
10
0.39"
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
144 5.67"
111 4.37"
251 9.88"
35 x 15 mm EN/IEC 60715
173 6.81"
10
0.39"
5.5 0.22"
5.4 0.21"
5
106.8 4.20"
AF40, AF52, AF65
+ BEY65-4, VM96-4, CA4-10, CA4-01
+ EF65 electronic overload relay
110.6 4.35"
155 6.10"
M6 ¼-20 UNC
45 1.78"
4.6 0.18"
100 3.94"
ø 4.2 0.17"
ø 6.4 0.25"
5 0.20"
1SBC101967S0201
110 4.33"
M4 8-32 UNC
ABB | 5/71
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
149 5.87"
195 7.68"
251 9.88"
151 5.94"
35 x 15 mm EN/IEC 60715
116 4.57"
5.5 0.22"
5.4 0.21"
5
106.8 4.20"
Line, Delta: AF80, AF96
+ Star: AF52, AF65
+ BEY96-4, VM96-4, CA4-10, CA4-01
+ EF96 electronic overload relay
110.6 4.35"
185 7.28"
45 1.77"
60 2.36"
2x
M6 ¼-20 UNC
2x
M4 8-32 UNC
ø 4.2 0.17"
ø 6.4 0.25"
ø 6.4 0.25"
4.8 0.19"
100 3.94"
M6 ¼-20 UNC
110 4.33"
10
0.39"
5 0.20"
1SBC101968S0201
70 2.76"
5/72 | ABB
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
126 4.96"
281.5 11.08"
270 10.63"
5
AF116, AF140, AF146
+ BEY140-4, VM19
+ EF146 electronic overload relay
60 2.36"
30 1.18"
60 2.36"
30 1.18"
14 x
M4 8-32 UNC
43.8 1.72"
100 3.94"
30 1.18"
21.5
94.7 3.73"
0.85"
2x
M5 10-24 UNC
1SFC101172C0201
37 1.46"
ABB | 5/73
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
310 12.20"
369 14.53"
Line, Delta: AF190, AF205
+ Star: AF116, AF140, AF146
+ BEY190-4, VM140/190
+ EF205 electronic overload relay
12 x
M5 10-24 UNC
35
1.38"
70 2.76"
35
75 2.95"
30 1.18"
1.38"
100 3.94"
0.81"
20.5
165 6.50"
4x
M4 8-32 UNC
1SFC101173C0201
112 4.42"
5
152 5.98"
5/74 | ABB
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
152 5.98"
369 14.53"
315 12.40"
5
AF190, AF205
+ BEY205-4, VM19
+ EF205 electronic overload relay
16 x
M5 10-24 UNC
35
70 2.76"
35
1.38"
70 2.76"
35
1.38"
25.5
82 3.23"
1.00"
165 6.50"
1.38"
37 1.46"
1SFC101174C0201
50 1.97"
ABB | 5/75
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
395 15.55"
417 16.42"
Line, Delta: AF265, AF305, AF370
+ Star: AF190, AF205
+ BEY265-4, VM205/265
+ EF370 electronic overload relay
43.75
96.25 3.79"
43.75
1.72"
93.12 3.67"
35
1.38"
16 x
M5 10-24 UNC
29
1.14"
187 7.36"
165 6.50"
1.72"
112 4.41"
35
1.38"
1SFC101175C0201
5
180 7.09"
5/76 | ABB
Star-delta starters protected by electronic overload relay
With AF contactors - Open type version in kit form
Main dimensions
mm, inches
420 16.54"
180 7.09"
417 16.42"
5
AF205, AF305, AF370
+ BEY370-4, VM19
+ EF370 electronic overload relay
43.75
96.25 3.79"
43.75
1.72"
96.25 3.79"
43.75
16 x
M5 10-24 UNC
1.72"
1SFC101176C0201
112 4.41"
29
1.14"
187 7.36"
1.72"
35
1.38"
ABB | 5/77
Summary_5-2
5
5/78 | ABB
AF 3-pole contactors
Overview 5/80
Ordering details
4 to 45 kW / 5 to 60 hp
AF09 … AF38
AC / DC operated
5/82
AF09Z … AF38Z
AC / DC operated - low consumption
5/83
AF40 ... AF96
AC / DC operated
5/84
Main accessories
5/86
55 to 200 kW / 75 to 350 hp
AF116 ... AF146
AC / DC operated
5/88
AF190 ... AF370
AC / DC operated
5/90
Main accessories
5/92
AF116 ... AF146
AC / DC operated with 1 N.O. + 1 N.C.
5/94
AF190 ... AF370
AC / DC operated with 1 N.O. + 1 N.C.
5/96
Main accessories
5
5/98
200 to 560 kW / 350 to 900 hp
AF400 ... AF750
AC / DC operated with 1 N.O. + 1 N.C.
AF1250 ... AF2650
AC / DC operated with 1 N.O. + 1 N.C.
Main accessories
5/100
5/101
5/102
4 to 45 kW / 5 to 60 hp - 2-stack
AF09 ... AF38
AC / DC operated
5/104
AF09Z ... AF38Z
AC / DC operated - low consumption
5/105
AF40 ... AF65
AC / DC operated
5/106
AF80 ... AF96
AC / DC operated
Main accessories
5/107
5/108
55 to 560 kW / 75 to 900 hp
AF116 ... AF146
AC / DC operated with 2 N.O. + 2 N.C.
5/110
AF190 ... AF370
AC / DC operated with 2 N.O. + 2 N.C.
5/112
Main accessories
5/114
AF400 ... AF750
AC / DC operated with 2 N.O. + 2 N.C.
5/116
AF1250 ... AF2650
AC / DC operated with 2 N.O. + 2 N.C.
5/117
Main accessories
5/118
5/120
5/137
Terminal marking and positioning
5/141
Main dimensions
5/144
Voltage code table
5/392
Summary_5-2
Technical data
Electrical durability
ABB | 5/79
3-pole contactors, for motor control and power switching
Type
AF09
AF12
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
220 - 230 - 240 V
380 - 400 V
415 V
440 V
500 V
690 V
1000 V
380 - 400 V
θ ≤ 40 °C, 690 V
kW
kW
kW
kW
kW
kW
kW
A
A
2.2
4
4
4
5.5
5.5
—
9
25
3
5.5
5.5
5.5
7.5
7.5
—
12
28
4
7.5
9
9
9
9
—
18
30
6.5
11
11
15
15
15
—
26
45
9
15
15
18.5
18.5
18.5
—
32
50
11
18.5
18.5
22
22
22
—
38
50
11
18.5
22
22
22
22
—
40
70
15
22
30
30
30
30
—
53
100
18.5
30
37
37
37
37
—
65
105
22
37
45
45
45
45
—
80
125
25
45
55
55
55
55
—
96
130
120 V
240 V
200 - 208 V
220 - 240 V
440 - 480 V
550 - 600 V
600 V
hp
hp
hp
hp
hp
hp
A
0.75
1.5
2
2
5
7.5
25
00
1
2
3
3
7.5
10
28
0
1.5
3
5
5
10
15
30
—
2
3
7.5
7.5
15
20
45
1
2
5
10
10
20
25
50
—
2
5
10
10
25
30
50
—
3
7.5
10
15
30
40
60
2
3
10
15
20
40
50
80
—
5
15
20
25
50
60
90
—
7.5
15
25
30
60
75
105
3
7.5
20
30
30
60
75
115
—
AC / DC Control supply
5
IEC
AC-3 Rated operational power
θ ≤ 60 °C for AF09 ... AF370
θ ≤ 55 °C for AF400 ... AF2650
Rated operational current
AC-1 Rated operational current
UL / CSA 1-phase motor rating
3-phase motor rating
NEMA
General use rating
NEMA Size
Main accessories
Auxiliary contact blocks
Front mounting
Timers
Side mounting
Electronic
Interlocking units
Mechanical
CA4-10 (1 x N.O.)
CA4-01 (1 x N.C.)
CAL4-11 (1 x N.O. + 1 x N.C.)
TEF4-ON
TEF4-OFF
VM4
VM96-4
Mechanical / Electrical
For reversing contactors
VEM4
BER16-4
BER38-4
Built-in surge protection
BER65-4
BER96-4
Thermal relays
Class 10
TF42
(0.10…38 A)
TF65
(22...67 A)
TF96
(40...96 A)
Electronic relays
Class 10E, 20E, 30E
EF19
(0.10…18.9 A)
EF65
(20...70 A)
EF96
(36...100 A)
Thermal / magnetic protection
Class 10
MS116 (0.10...32 A)
Connection sets
Surge suppressors
Overload relays
(Class 10A for TF140, TA200DU)
EF19 (0.10…18.9 A)
EF45 (9…45 A)
Manual motor starters
MS450
(28...50 A)
lcs up to 50 kA
lcs up to 50 kA for class 10 A
MS132 (0.10...32 A)
lcs up to 100 kA
MS495
(45…100 A)
Ics up to 50 kA
MS497
(22…100 A)
Ics up to 100 kA
Magnetic only types
MO132
MO496
(0.16...32 A)
Ics up to 100 kA
(32…100 A)
Ics up to 100 kA
MO450 (40…50 A)
Ics up to 50 kA
Accessories
5/80 | ABB
For contactor mounting
BEA16-4
BEA38-4
MO495 (63…100 A)
Ics up to 50 kA
AF116
AF140
AF146 AF190
AF205
AF265 AF305 AF370 AF400
AF460
AF580
AF750
AF1250 AF1350
AF1650
AF2050 AF2650
30
55
55
75
75
55
—
116
160
37
75
75
90
90
75
—
140
200
45
75
75
90
90
90
75
146
225
55
90
90
110
110
132
110
190
275
55
110
110
132
132
160
132
205
350
75
132
132
160
160
200
132
265
400
90
160
160
160
200
250
132
305
500
110
200
200
200
250
315
132
370
600
110
200
220
220
250
315
220
400
600
132
250
250
250
315
355
280
460
700
160
315
355
355
400
500
355
580
800
220
400
425
450
520
600
400
750
1050
—
—
—
—
—
—
—
—
1260
257
475
500
560
560
750
—
860
1350
315
560
600
670
700
900
—
1050
1650
—
—
—
—
—
—
—
—
2050
—
—
—
—
—
—
—
—
2650
—
—
30
40
75
100
160
—
—
—
40
50
100
125
200
4
—
—
40
50
100
125
200
—
—
—
50
60
125
150
250
—
—
—
60
75
150
200
300
—
—
—
75
100
200
250
350
5
—
—
100
125
250
300
400
—
—
—
125
150
300
350
520
—
—
—
125
150
350
400
550
—
—
—
150
200
400
500
650
6
—
—
200
250
500
600
750
—
—
—
250
300
600
700
900
7
—
—
—
—
—
—
1210
—
—
—
—
400
800
1000
1350
—
—
—
—
450
900
1150
1650
8
—
—
—
—
—
—
2100
—
—
—
—
—
—
—
2700
—
CAL19-11 (1 x N.O. + 1 x N.C.)
CAL18-11 (1 x N.O. + 1 x N.C.)
VM19
VM750H
VM750V
(for same size contactors)
BER140-4
BER205-4
TF140DU
TA200DU
θ ≤ 55 °C
EF146
(66...142 A)
(54...150 A)
θ ≤ 55 °C
EF205
5
VM1650H
BER370-4
BEM460-30
BEM750-30
EF370
EF460 (150…500 A)
EF750
(66...200 A)
(63...210 A)
(115...380 A)
(250…800 A)
E1250DU
(375…1250 A)
Short-circuit protection devices
1SBC101908S0201
MCCB and switch-fuses
ABB | 5/81
AF09 ... AF38 3-pole contactors
4 to 18.5 kW
AC / DC operated
1SBC101011V0014
Description
AF09-30-10
AF09 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
1SBC101001V0014
5
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
25
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc min. … Uc max.
use
rating
600 V AC
hp
5
A
25
AF26-30-00
5.5
28
7.5
30
7.5
28
10
30
11
45
15
45
15
50
20
50
18.5
50
25
50
Auxiliary Type
contacts (1)
fitted
V 50/60 Hz
24...60
V DC
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
(2)
48...130
100...250
250...500
(2)
48...130
100...250
250...500
(2)
48...130
100...250
250...500
(2)
(2)
(2)
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
Order code
Weight
Pkg
(1 pce)
AF09-30-10-41
AF09-30-01-41
AF09-30-10-12
AF09-30-01-12
AF09-30-10-13
AF09-30-01-13
AF09-30-10-14
AF09-30-01-14
AF12-30-10-41
AF12-30-01-41
AF12-30-10-12
AF12-30-01-12
AF12-30-10-13
AF12-30-01-13
AF12-30-10-14
AF12-30-01-14
AF16-30-10-41
AF16-30-01-41
AF16-30-10-12
AF16-30-01-12
AF16-30-10-13
AF16-30-01-13
AF16-30-10-14
AF16-30-01-14
AF26-30-00-41
AF26-30-00-12
AF26-30-00-13
AF26-30-00-14
AF30-30-00-41
AF30-30-00-12
AF30-30-00-13
AF30-30-00-14
AF38-30-00-41
AF38-30-00-12
AF38-30-00-13
AF38-30-00-14
kg
0.270
0.270
0.270
0.270
0.270
0.270
0.310
0.310
0.270
0.270
0.270
0.270
0.270
0.270
0.310
0.310
0.270
0.270
0.270
0.270
0.270
0.270
0.310
0.310
0.310
0.310
0.310
0.350
0.310
0.310
0.310
0.350
0.310
0.310
0.310
0.350
1SBL137001R4110
1SBL137001R4101
1SBL137001R1210
1SBL137001R1201
1SBL137001R1310
1SBL137001R1301
1SBL137001R1410
1SBL137001R1401
1SBL157001R4110
1SBL157001R4101
1SBL157001R1210
1SBL157001R1201
1SBL157001R1310
1SBL157001R1301
1SBL157001R1410
1SBL157001R1401
1SBL177001R4110
1SBL177001R4101
1SBL177001R1210
1SBL177001R1201
1SBL177001R1310
1SBL177001R1301
1SBL177001R1410
1SBL177001R1401
1SBL237001R4100
1SBL237001R1200
1SBL237001R1300
1SBL237001R1400
1SBL277001R4100
1SBL277001R1200
1SBL277001R1300
1SBL277001R1400
1SBL297001R4100
1SBL297001R1200
1SBL297001R1300
1SBL297001R1400
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
(2) For 24...60 V 50/60 Hz - 20...60 V DC, use AF..-30-..-11 (see voltage code table).
AF..-30-..-11 not suitable for direct control by PLC-output.
mm, inches
86 3.39"
70 2.76"
5.5 0.22"
10 0.39"
AF09, AF12, AF16
5/82 | ABB
5 0.20"
AF26, AF30, AF38
35 1.38"
80 3.15"
ø 4.2 0.17"
5.5 0.22"
60 2.36"
6 0.24"
3.15"
60802.36"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
2x
M4 8-32 UNC
5.5 0.22"
10 0.39"
1SBC101371S0201 - Rev. B
35 1.38"
45 1.77"
ø 4.2 0.17"
71 2.80"
35 mm EN/IEC 60715
77 3.03"
45 1.77"
5 0.20"
Main dimensions
5 0.20"
AF09Z ... AF38Z 3-pole contactors
4 to 18.5 kW
AC / DC operated - low consumption
1SBC101011V0014
Description
AF09Z-30-10
AF09Z ... AF38Z contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and
12...250 V DC
-- can manage large control voltage variations
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
25
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc min. … Uc max.
use
rating
600 V AC
hp
5
A
25
V 50/60 Hz V DC
12...20
AF26Z-30-00
5.5
28
7.5
30
7.5
28
10
30
11
45
15
45
15
50
20
50
18.5
50
25
50
24...60
20...60
48...130
48...130
100...250
100...250
-
12...20
24...60
20...60
48...130
48...130
100...250
100...250
-
12...20
24...60
20...60
48...130
48...130
100...250
100...250
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
Auxiliary Type
contacts (1)
fitted
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
Order code
Weight
5
Pkg
(1 pce)
AF09Z-30-10-20
AF09Z-30-01-20
AF09Z-30-10-21
AF09Z-30-01-21
AF09Z-30-10-22
AF09Z-30-01-22
AF09Z-30-10-23
AF09Z-30-01-23
AF12Z-30-10-20
AF12Z-30-01-20
AF12Z-30-10-21
AF12Z-30-01-21
AF12Z-30-10-22
AF12Z-30-01-22
AF12Z-30-10-23
AF12Z-30-01-23
AF16Z-30-10-20
AF16Z-30-01-20
AF16Z-30-10-21
AF16Z-30-01-21
AF16Z-30-10-22
AF16Z-30-01-22
AF16Z-30-10-23
AF16Z-30-01-23
AF26Z-30-00-20
AF26Z-30-00-21
AF26Z-30-00-22
AF26Z-30-00-23
AF30Z-30-00-20
AF30Z-30-00-21
AF30Z-30-00-22
AF30Z-30-00-23
AF38Z-30-00-20
AF38Z-30-00-21
AF38Z-30-00-22
AF38Z-30-00-23
kg
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
0.350
1SBL136001R2010
1SBL136001R2001
1SBL136001R2110
1SBL136001R2101
1SBL136001R2210
1SBL136001R2201
1SBL136001R2310
1SBL136001R2301
1SBL156001R2010
1SBL156001R2001
1SBL156001R2110
1SBL156001R2101
1SBL156001R2210
1SBL156001R2201
1SBL156001R2310
1SBL156001R2301
1SBL176001R2010
1SBL176001R2001
1SBL176001R2110
1SBL176001R2101
1SBL176001R2210
1SBL176001R2201
1SBL176001R2310
1SBL176001R2301
1SBL236001R2000
1SBL236001R2100
1SBL236001R2200
1SBL236001R2300
1SBL276001R2000
1SBL276001R2100
1SBL276001R2200
1SBL276001R2300
1SBL296001R2000
1SBL296001R2100
1SBL296001R2200
1SBL296001R2300
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil
terminals: A1+ for the positive pole and A2- for the negative pole.
mm, inches
86 3.39"
70 2.76"
5.5 0.22"
10 0.39"
AF09Z, AF12Z, AF16Z
5 0.20"
35 1.3
80 3.15"
ø 4.2 0
5.5 0.22"
60 2.36"
6 0.24"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
2x
M4 8-32 UNC
5.5 0.22"
10 0.39"
AF26Z, AF30Z, AF38Z
ABB | 5/83
1SBC101372S0201 - Rev. B
35 1.38"
45 1.77"
ø 4.2 0.17"
71 2.80"
35 mm EN/IEC 60715
77 3.03"
45 1.77"
5 0.20"
Main dimensions
3.15"
60802.36"
1SBC101001V0014
Ordering details
5 0
AF40 ... AF96 3-pole contactors
18.5 to 45 kW
AC / DC operated
Description
1SBC101014V0014
AF40 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
AF40-30-00
Ordering details
IEC
5
1SBC101016V0014
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
18.5
70
UL / CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc min. … Uc max.
use
rating
600 V AC
hp
30
A
60
22
100
40
80
30
105
50
90
37
125
60
105
45
130
60
115
V 50/60 Hz
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
AF80-30-00
Auxiliary Type
contacts (1)
fitted
V DC
20...60 (2)
48...130
100...250
250...500
20...60 (2)
48...130
100...250
250...500
20...60 (2)
48...130
100...250
250...500
20...60 (2)
48...130
100...250
250...500
20...60 (2)
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Order code
Weight
Pkg
(1 pce)
AF40-30-00-41
AF40-30-00-11
AF40-30-00-12
AF40-30-00-13
AF40-30-00-14
AF52-30-00-41
AF52-30-00-11
AF52-30-00-12
AF52-30-00-13
AF52-30-00-14
AF65-30-00-41
AF65-30-00-11
AF65-30-00-12
AF65-30-00-13
AF65-30-00-14
AF80-30-00-41
AF80-30-00-11
AF80-30-00-12
AF80-30-00-13
AF80-30-00-14
AF96-30-00-41
AF96-30-00-11
AF96-30-00-12
AF96-30-00-13
AF96-30-00-14
1SBL347001R4100
1SBL347001R1100
1SBL347001R1200
1SBL347001R1300
1SBL347001R1400
1SBL367001R4100
1SBL367001R1100
1SBL367001R1200
1SBL367001R1300
1SBL367001R1400
1SBL387001R4100
1SBL387001R1100
1SBL387001R1200
1SBL387001R1300
1SBL387001R1400
1SBL397001R4100
1SBL397001R1100
1SBL397001R1200
1SBL397001R1300
1SBL397001R1400
1SBL407001R4100
1SBL407001R1100
1SBL407001R1200
1SBL407001R1300
1SBL407001R1400
kg
0.970
0.970
0.970
0.950
0.950
0.970
0.970
0.970
0.950
0.950
0.970
0.970
0.970
0.950
0.950
1.220
1.220
1.220
1.170
1.170
1.220
1.220
1.220
1.170
1.170
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
(2) AF..-30-..-11 not suitable for direct control by PLC-output.
mm, inches
111 111
4.37"4.37"
5/84 | ABB
7 0.28"
7 0.28"
35 x 15 mm EN/IEC 60715
35 x 15 mm EN/IEC 60715
6 0.24"
6 0.24"
119.5 4.70"
119.5 4.70"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5.5 0.22"
5.5 0.22"
10 0.39"
10 0.39"
AF40, AF52, AF65
116 4.57" 116 4.57"
70 2.76" 70 2.76"
7 0.28"
7 0.28"
6 0.24"
119.5 4.70"
119.5 4.70"
6 0.24"
55 2.17"
55 2.17"
5.5 0.22" 5.5 0.22"
1SBC101740S0201 - Rev. A
Main dimensions
10 0.39" 10 0.39"
AF80, AF96
N1
5
ABB | 5/85
AF09 ... AF96 3-pole contactors
Main accessories
Contactor and main accessories (other accessories available)
AF09 ... AF65
VEM4 mechanical and electrical interlock set including:
– VM4 mechanical interlock unit with 2 fixing clips
– VE4 electrical interlock block with A2-A2 connection
AF contactor
(without top mounted
coil terminal block)
AF09 ... AF96
AF contactor
CAT4-11
2-pole auxiliary contact
and A1/A2 coil terminal block
Fixing clips
AF contactor
BX4-CA
Protective cover
5
TEF4
Electronic timer
VM
A2
A2
BX4-CA
Protective cover
CA4
4-pole auxiliary
contact block
CAL4-11
2-pole auxiliary
contact block
AF09 ... AF38
BX4-CA
Protective cover
CA4, CC4
1-pole auxiliary
contact block
BX4
Protective cover
CA4, CC4
1-pole auxiliary
contact block
TF
EF
Overload relay
VE4
CAL4-11
2-pole auxiliary
contact block
CA4, CC4
1-pole auxiliary
contact block
TF42
EF
Overload relay
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Built-in
Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
Main
poles
Electronic
timer
1-pole CA4
1-pole CC4
2-pole CAT4-11
4-pole CA4
TEF4
Electrical and
mechanical interlock set
Side-mounted accessories
Auxiliary contact blocks
(between 2 contactors)
Left side
VEM4
2-pole CAL4-11
Right side
Max. N.C. built-in and add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5
AF09 ... AF16
AF09 ... AF16
AF26 ... AF38
3
3
3
0
0
0
0
1
0
1
0
0
AF40 ... AF65
AF80, AF96
3
3
0
0
0
0
0
0
4 max.
2 max.
3 max.
or 1
or 1
–
or 1
–
–
or 1
or 1
–
–
–
+ 1
+ 1
+ 1
+ 1
–
+ 1
or 1
+ 1
+ 1
+ 1
+ 1
Max. add-on N.C. auxiliary contacts: 6 N.C. max. on positions 1, 1 ±30°, 2, 3, 4, 5
4 max.
4 max.
or 1
–
or 1
or 1
or 1
or 1
–
–
Contactor types
AF09 ... AF38
AF26 ... AF38
AF40 ... AF65
AF80, AF96
Thermal overload relays
TF42 (0.10...38 A)
TF42 (0.10...38 A)
TF65 (22...67 A)
TF96 (40...96 A)
Electronic overload relays
EF19 (0.10...19 A)
EF45 (9...45 A)
EF65 (20...70 A)
EF96 (36...100 A)
The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.
(1) Direct mounting - No kit required.
5/86 | ABB
1SBC101748S0201 - Rev. A
Overload relays fitting details (1)
AF09 ... AF96 3-pole contactors
Main accessories
1SBC100001V0014
Ordering details (1)
1SBC100007V0014
For contactors
CA4-10
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Front-mounted instantaneous auxiliary contact blocks
AF09 ... AF96
1 0
– –
CA4-10
1 0
– –
CA4-10-T
0 1
– –
CA4-01
0 1
– –
CA4-01-T
AF09 ... AF16..-30-10
2 2
– –
CA4-22M
AF26 ... AF96..-30-00
2 2
– –
CA4-22E
AF09 ... AF16..-30-01
2 2
– –
CA4-22U
1SBC100006V0014
CAL4-11
1SBC100002V0014
CA4-22E
CAT4-11E
1SBN010110R1010
1SBN010110T1010
1SBN010110R1001
1SBN010110T1001
1SBN010140R1122
1SBN010140R1022
1SBN010140R1322
1
10
1
10
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
AF09 ... AF96
– –
1 0
CC4-10
1SBN010111R1010
1
– –
0 1
CC4-01
1SBN010111R1001
1
0.014
0.014
Side-mounted instantaneous auxiliary contact blocks
AF09 ... AF96
1 1
– –
CAL4-11
1 1
– –
CAL4-11-T
1
10
0.040
0.040
1
1
1
0.040
0.040
0.040
1SBN030105T1000
1SBN033405T1000
10
10
0.005
0.006
1SBN030111R1000
1
0.035
1SBN010120R1011
1SBN010120T1011
Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks
AF09 ... AF16..-30-10
1 1
– –
CAT4-11M
1SBN010151R1111
AF26 ... AF65..-30-00
1 1
– –
CAT4-11E
1SBN010151R1011
AF09 ... AF16..-30-01
1 1
– –
CAT4-11U
1SBN010151R1311
5
Note: CAT4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC.
1SBC100011V0014
Mechanical interlock unit
AF09 ... AF38
AF40 ... AF96
Note: VM4 and VM96-4 include 2 fixing clips (BB4) to maintain together both contactors.
Mechanical and electrical interlock set
AF09 ... AF16
0 2
AF26 ... AF38
VEM4
For contactors
KM2
A2
VEM4
Time delay
range
Delay
type
Auxiliary Type
contacts
Order code
Pkg
qty
selected by
switch
1SBC100004V0014
Electronic timers
AF09 ... AF96
0.1...1 s
1...10 s
10...100 s
1SBC100014V0014
1SBC100016V0014
BEA16-4
Weight
(1 pce)
kg
ON-delay
1 1
TEF4-ON
1SBN020112R1000
1
0.065
OFF-delay
1 1
TEF4-OFF
1SBN020114R1000
1
0.065
BEA16-4
1SBN081306T1000
10
0.025
BEA26-4
1SBN082306T1000
10
0.025
BEA38-4
1SBN082306T2000
10
0.030
Connection sets for reversing contactors
AF09 ... AF16
AF26 ... AF38
AF40 ... AF65
AF80 ... AF96
BER16-4
BER38-4
BER65-4
BER96-4
1SBN081311R1000
1SBN082311R1000
1SBN083411R1000
1SBN083911R1000
1
1
1
1
0.045
0.100
0.175
0.250
Connection sets for star-delta starting
AF09 ... AF16
With or without VM4
AF26 ... AF38
With or without VM4
AF40 ... AF65
With or without VM96-4
AF80 ... AF96
With or without VM96-4
BEY16-4
BEY38-4
BEY65-4
BEY96-4
1SBN081313R2000
1SBN082713R2000
1SBN083413R2000
1SBN083913R2000
1
1
1
1
0.050
0.110
0.200
0.250
Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.
TEF4-ON
BER16-4
VEM4
Note: - VEM4 includes a VM4 mechanical interlock unit with 2 fixing clips (BB4), a VE4 electrical interlock block. VE4 block must be used with A2-A2
connection to respect the electrical connection diagram.
- VEM4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC.
01NC
KM1
A2
– –
Connecting links with manual motor starters
AF09 ... AF16
with MS116-0.16 … MS116-25,
MS132-0.16 … MS132-25
AF26 ... AF38
with MS116-0.16 … MS116-16,
MS132-0.16 ... MS132-10
with MS116-20 … MS116-32,
MS132-12 ... MS132-32
(1) For more information, refer to main catalog "Accessories" section.
ABB | 5/87
1SBC101749S0201
01 NC
VM4
VM96-4
AF116 ... AF146 3-pole contactors
55 to 75 kW
AC / DC operated
1SFC101005V0001
Description
AF146-30-00
AF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC, AF146 up to 1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
1SFC101006V0001
5
AF146-30-00B
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
A
Auxiliary Type
contacts (1)
fitted
Order code
Weight
Pkg
(1 pce)
V 50/60 Hz V DC
For connection with built-in cable clamps
55
75
24...60
20...60
160
160
48...130 48...130
100...250 100...250
250...500 250...500
75
100
24...60
20...60
200
200
48...130 48...130
100...250 100...250
250...500 250...500
75
100
24...60
20...60
225
200
48...130 48...130
100...250 100...250
250...500 250...500
With bar connections
55
75
160
160
75
200
100
200
75
225
100
200
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
kg
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF116-30-00-11
AF116-30-00-12
AF116-30-00-13
AF116-30-00-14
AF140-30-00-11
AF140-30-00-12
AF140-30-00-13
AF140-30-00-14
AF146-30-00-11
AF146-30-00-12
AF146-30-00-13
AF146-30-00-14
1SFL427001R1100
1SFL427001R1200
1SFL427001R1300
1SFL427001R1400
1SFL447001R1100
1SFL447001R1200
1SFL447001R1300
1SFL447001R1400
1SFL467001R1100
1SFL467001R1200
1SFL467001R1300
1SFL467001R1400
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF116-30-00B-11
AF116-30-00B-12
AF116-30-00B-13
AF116-30-00B-14
AF140-30-00B-11
AF140-30-00B-12
AF140-30-00B-13
AF140-30-00B-14
AF146-30-00B-11
AF146-30-00B-12
AF146-30-00B-13
AF146-30-00B-14
1SFL427002R1100
1SFL427002R1200
1SFL427002R1300
1SFL427002R1400
1SFL447002R1100
1SFL447002R1200
1SFL447002R1300
1SFL447002R1400
1SFL467002R1100
1SFL467002R1200
1SFL467002R1300
1SFL467002R1400
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
5/88 | ABB
30 1.18"
AF116, AF140, AF146-30-00B
19.5 0.77"
1SFC101088C0201 - Rev. C
AF116, AF140, AF146-30-00
D
150 5.91"
150 5.91"
30 1.18"
SECTION E-E
126 4.96"
90 3.54"
D
19.5 4.96"
D
D
E
SECTION E-E
126 4.96"
90 3.54"
55.5 0.22"
E
mm, inches
55.5 2.18"
Main dimensions
AF116 ... AF146 3-pole contactors with built-in PLC interface
55 to 75 kW
AC / DC operated
Description
1SFC101182V0001
AF116 ... AF146 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC, AF146 up to 1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...500 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and
100...250 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF146-30-00
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
A
Auxiliary Type
contacts (1)
fitted
Order code
Weight
5
Pkg
(1 pce)
V 50/60 Hz V DC
kg
1SFC101185V0001
For connection with built-in cable clamps
AF146-30-00B
55
160
75
160
75
200
100
200
75
225
100
200
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
AF116-30-00-33
AF116-30-00-34
AF140-30-00-33
AF140-30-00-34
AF146-30-00-33
AF146-30-00-34
1SFL427001R3300
1SFL427001R3400
1SFL447001R3300
1SFL447001R3400
1SFL467001R3300
1SFL467001R3400
1.750
1.750
1.750
1.750
1.750
1.750
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
AF116-30-00B-33
AF116-30-00B-34
AF140-30-00B-33
AF140-30-00B-34
AF146-30-00B-33
AF146-30-00B-34
1SFL427002R3300
1SFL427002R3400
1SFL447002R3300
1SFL447002R3400
1SFL467002R3300
1SFL467002R3400
1.500
1.500
1.500
1.500
1.500
1.500
With bar connections
55
160
75
160
75
200
100
200
75
225
100
200
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
AF116 ... AF146 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
Main dimensions
mm, inches
E
AF116, AF140, AF146-30-00
19.5 0.77"
D
55.5 2.18"
142.5 5.61"
1SFC101164C0201
30 1.18"
D
150 5.91"
150 5.91"
D
19.5 4.96"
D
90 3.54"
142.5 5.61"
90 3.54"
55.5 0.22"
E
30 1.18"
AF116, AF140, AF146-30-00B
ABB | 5/89
AF190 ... AF370 3-pole contactors
90 to 200 kW
AC / DC operated
Description
1SFC101012V0001
AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-30-00
Ordering details
1SFC101017V0001
5
AF370-30-00
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
90
275
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
125
A
250
110
350
150
300
140
400
200
350
160
500
250
400
200
600
300
520
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
Auxiliary Type
contacts (1)
fitted
V DC
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF190-30-00-11
AF190-30-00-12
AF190-30-00-13
AF190-30-00-14
AF205-30-00-11
AF205-30-00-12
AF205-30-00-13
AF205-30-00-14
AF265-30-00-11
AF265-30-00-12
AF265-30-00-13
AF265-30-00-14
AF305-30-00-11
AF305-30-00-12
AF305-30-00-13
AF305-30-00-14
AF370-30-00-11
AF370-30-00-12
AF370-30-00-13
AF370-30-00-14
Order code
Weight
Pkg
(1 pce)
kg
3.000
3.000
3.000
3.000
3.000
3.000
3.000
3.000
4.605
4.605
4.605
4.605
4.605
4.605
4.605
4.605
4.605
4.605
4.605
4.605
1SFL487002R1100
1SFL487002R1200
1SFL487002R1300
1SFL487002R1400
1SFL527002R1100
1SFL527002R1200
1SFL527002R1300
1SFL527002R1400
1SFL547002R1100
1SFL547002R1200
1SFL547002R1300
1SFL547002R1400
1SFL587002R1100
1SFL587002R1200
1SFL587002R1300
1SFL587002R1400
1SFL607002R1100
1SFL607002R1200
1SFL607002R1300
1SFL607002R1400
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
Main dimensions
mm, inches
A
180 7.09"
ø 10.5 0.41"
35.5 1.40"
5 0.20"
33.4 1.31"
94.7 3.73"
5 0.20"
43.75 1.72"
AF265, AF305, AF370
1SFC101089C0201 - Rev. D
AF190, AF205
19.5 0.77"
225 8.86"
196 7.72"
35 1.38"
35.5 1.40"
29.5 1.16"
ø 8.5 0.33"
83.5 3.29"
105 4.13"
5/90 | ABB
140 5.51"
SECTION B-B
152 5.98"
B
AF190 ... AF370 3-pole contactors with built-in PLC interface
90 to 200 kW
AC / DC operated
1SFC101167V0001
Description
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
90
275
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
125
A
250
110
350
150
300
140
400
200
350
160
500
250
400
200
600
300
520
V 50/60 Hz
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
Auxiliary Type
contacts (1)
fitted
V DC
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF190-30-00-33
AF190-30-00-34
AF205-30-00-33
AF205-30-00-34
AF265-30-00-33
AF265-30-00-34
AF305-30-00-33
AF305-30-00-34
AF370-30-00-33
AF370-30-00-34
Order code
Weight
5
Pkg
(1 pce)
kg
3.000
3.000
3.000
3.000
4.605
4.605
4.605
4.605
4.605
4.605
1SFL487002R3300
1SFL487002R3400
1SFL527002R3300
1SFL527002R3400
1SFL547002R3300
1SFL547002R3400
1SFL587002R3300
1SFL587002R3400
1SFL607002R3300
1SFL607002R3400
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
AF190 ... AF370 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
Main dimensions
mm, inches
A
140 5.51"
SECTION B-B
19.5 0.77"
195.5 7.70"
ø 10.5 0.41"
35.5 1.40"
5 0.20"
169.5 6.67"
B
AF190, AF205
33.4 1.31"
225 8.86"
94.7 3.73"
5 0.20"
1SFC101165C0201
35 1.38"
35.5 1.40"
29.5 1.16"
ø 8.5 0.33"
83.5 3.29"
105 4.13"
196 7.72"
1SFC101132V0001
AF205-30-00
AF370-30-00
AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and
100...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
43.75 1.72"
AF265, AF305, AF370
ABB | 5/91
AF116 ... AF370 3-pole contactors
Main accessories
Main accessories
(other accessories available)
CAL19-11
2-pole auxiliary
contact block
CAL19-11B
2-pole auxiliary
contact block
LW
Terminal
enlargement
VM
Mechanical
interlock
5
AF contactor
with bar connections
CAL19-11
2-pole auxiliary
contact block
LT
Terminal shroud
AF contactor
with built-in cable clamps
CAL19-11B
2-pole auxiliary
contact block
TF/TA
Thermal overload relay
EF
Electronic overload relay
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL19-11
AF116 ... AF370
3 0
0 0
2 x CAL19-11
+
2 x CAL19-11B
AF116 ... AF370
3 0
0 0
2 x CAL19-11 (1)
+
2 x CAL19-11B (1)
(1) Total number of auxiliary contact blocks for the two contactors.
Mechanical interlock units
CAL19-11B
(between two contactors)
–
+
VM... (2)
(2) Interlock type, according to the contactor ratings (see "Accessories").
Contactor types
AF116 ... AF140
AF146
AF190, AF205
AF265 ... AF370
Thermal overload relays
TF140DU (66...142 A)
–
TA200DU (66...200 A)
–
Electronic overload relays
EF146 (54...150 A)
EF146 (54...150 A)
EF205 (63...210 A)
EF370 (115...380 A)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
(1) Direct mounting - No kit required.
5/92 | ABB
1SFC101135C0201
Overload relays fitting details (1)
AF116 ... AF370 3-pole contactors
Main accessories
Ordering details (1)
For contactors
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
1SFC101071V0001
kg
Side-mounted instantaneous auxiliary contact blocks
1
1 CAL19-11
AF116 ... AF370
1
1 CAL19-11B
1SFN010820R1011
1SFN010820R3311
2
2
0.050
0.050
Mechanical interlock unit
AF116 ... AF370
AF116 ... AF146 and AF190, AF205
AF190, AF205 and AF265 ... AF370
VM19
VM140/190
VM205/265
1SFN030300R1000
1SFN034403R1000
1SFN035203R1000
1
1
1
0.054
0.088
0.090
LT140-30L
LT205-30C
LT205-30L
LT205-30Y
1SFN124203R1000
1SFN124801R1000
1SFN124803R1000
1SFN124804R1000
2
2
2
1
0.070
0.050
0.220
0.050
LT370-30C
LT370-30L
LT370-30Y
1SFN125401R1000
1SFN125403R1000
1SFN125404R1000
2
2
1
0.035
0.280
0.075
LT370-30D
1SFN125406R1000
1
0.150
Type
Order code
Pkg
Weight
qty
(1 pce)
kg
CAL19-11
1SFC101041V0001
VM19
For contactors
bar
mm
Terminal enlargements
AF116 ... AF146
AF190 ... AF205
AF265 ... AF370
6.5
10.5
10.5
13 x 3
17.5 x 5
20 x 5
LW140
LW205
LW370
1SFN074207R1000
1SFN074807R1000
1SFN075407R1000
1
1
1
0.115
0.260
0.340
Terminal extension
AF116 ... AF146
AF190 ... AF250
AF265 ... AF370
6.5
8.5
10.5
13 x 3
17.5 x 5
20 x 5
LX140
LX205
LX370
1SFN074210R1000
1SFN074810R1000
1SFN075410R1000
1
1
1
0.072
0.180
0.234
1SFC101049V0001
LT370-30C
LX140
Dimensions
hole Ø
mm
5
(1) For more information, refer to "Accessories" section.
1SFC101134C0201
1SFC101035V0001
Terminal shrouds
AF116 ... AF146, with compression lugs
AF190, AF205, with cable clamps
AF190, AF205, with compression lugs
AF190, AF205, with shorting bar or between contactor
and TOL/EOL in DOL-starters
AF265 ... AF370, with cable clamps
AF265 ... AF370, with compression lugs
AF265 ... AF370, with shorting bar or between contactor
and TOL/EOL in DOL-starters
AF265 ... AF370, for use with extending cable clamps,
ATK300/2 and OZXB4
ABB | 5/93
AF116 ... AF146 3-pole contactors
55 to 75 kW
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
1SFC101001V0001
Description
AF146-30-11
AF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC, AF146 up to 1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
1SFC101008V0001
5
AF146-30-11B
UL / CSA
3-phase
motor
rating
480 V
Rated control ircuit
General voltage
Uc min. ... Uc max.
use
rating
600 V AC
hp
A
Auxiliary Type
contacts (1)
fitted
Order code
Weight
Pkg
(1 pce)
V 50/60 Hz V DC
For connection with built-in cable clamps
55
75
24...60
20...60
160
160
48...130 48...130
100...250 100...250
250...500 250...500
75
100
24...60
20...60
200
200
48...130 48...130
100...250 100...250
250...500 250...500
75
100
24...60
20...60
225
200
48...130 48...130
100...250 100...250
250...500 250...500
With bar connections
55
75
160
160
75
200
100
200
75
225
100
200
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AF116-30-11-11
AF116-30-11-12
AF116-30-11-13
AF116-30-11-14
AF140-30-11-11
AF140-30-11-12
AF140-30-11-13
AF140-30-11-14
AF146-30-11-11
AF146-30-11-12
AF146-30-11-13
AF146-30-11-14
1SFL427001R1111
1SFL427001R1211
1SFL427001R1311
1SFL427001R1411
1SFL447001R1111
1SFL447001R1211
1SFL447001R1311
1SFL447001R1411
1SFL467001R1111
1SFL467001R1211
1SFL467001R1311
1SFL467001R1411
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AF116-30-11B-11
AF116-30-11B-12
AF116-30-11B-13
AF116-30-11B-14
AF140-30-11B-11
AF140-30-11B-12
AF140-30-11B-13
AF140-30-11B-14
AF146-30-11B-11
AF146-30-11B-12
AF146-30-11B-13
AF146-30-11B-14
1SFL427002R1111
1SFL427002R1211
1SFL427002R1311
1SFL427002R1411
1SFL447002R1111
1SFL447002R1211
1SFL447002R1311
1SFL447002R1411
1SFL467002R1111
1SFL467002R1211
1SFL467002R1311
1SFL467002R1411
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
mm, inches
5/94 | ABB
D
D
30 1.18"
AF116, AF140, AF146-30-11B
1SFC101090C0201 - Rev. C
30 1.18"
AF116, AF140, AF146-30-11
126 4.96"
19.5 0.77"
150 5.91"
D
SECTION E-E
90 3.54"
55.5 2.18"
D
E
10 0.39"
150 5.91"
SECTION E-E
126 4.96"
90 3.54"
55.5 0.22"
10 0.39"
E
19.5 4.96"
Main dimensions
AF116 ... AF146 3-pole contactors with built-in PLC interface
55 to 75 kW
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
1SFC101083V0001
Description
AF146-30-11
AF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC, AF146 up to 1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and
100...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
A
Auxiliary Type
contacts (1)
fitted
Order code
Weight
5
Pkg
(1 pce)
V 50/60 Hz V DC
kg
160
75
160
75
200
100
200
75
225
100
200
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
1
1
1
1
1
1
1
1
1
1
1
1
AF116-30-11-33
AF116-30-11-34
AF140-30-11-33
AF140-30-11-34
AF146-30-11-33
AF146-30-11-34
1SFL427001R3311
1SFL427001R3411
1SFL447001R3311
1SFL447001R3411
1SFL467001R3311
1SFL467001R3411
1.750
1.750
1.750
1.750
1.750
1.750
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
1
1
1
1
1
1
1
1
1
1
1
1
AF116-30-11B-33
AF116-30-11B-34
AF140-30-11B-33
AF140-30-11B-34
AF146-30-11B-33
AF146-30-11B-34
1SFL427002R3311
1SFL427002R3411
1SFL447002R3311
1SFL447002R3411
1SFL467002R3311
1SFL4670023R411
1.500
1.500
1.500
1.500
1.500
1.500
With bar connections
55
160
75
160
75
200
100
200
75
225
100
200
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
AF116 ... AF146 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
Main dimensions
E
30 1.18"
AF116, AF140, AF146-30-11
D
D
1SFC101166C0201
D
142.5 5.61"
19.5 0.77"
D
90 3.54"
10 0.39"
55.5 2.18"
142.5 5.61"
90 3.54"
150 5.91"
10 0.39"
mm, inches
19.5 4.96"
E
55.5 0.22"
AF146-30-11B
55
150 5.91"
1SFC101186V0001
For connection with built-in cable clamps
30 1.18"
AF116, AF140, AF146-30-11B
ABB | 5/95
AF190 ... AF370 3-pole contactors
90 to 200 kW
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
1SFC101013V0001
AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-30-11
Ordering details
1SFC101018V0001
5
AF370-30-11
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
90
275
UL / CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc min. ... Uc max.
use
rating
600 V AC
hp
125
A
250
110
350
150
300
140
400
200
350
160
500
250
400
200
600
300
520
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
V DC
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
Auxiliary Type
contacts (1)
fitted
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
Pkg
(1 pce)
AF190-30-11-11
AF190-30-11-12
AF190-30-11-13
AF190-30-11-14
AF205-30-11-11
AF205-30-11-12
AF205-30-11-13
AF205-30-11-14
AF265-30-11-11
AF265-30-11-12
AF265-30-11-13
AF265-30-11-14
AF305-30-11-11
AF305-30-11-12
AF305-30-11-13
AF305-30-11-14
AF370-30-11-11
AF370-30-11-12
AF370-30-11-13
AF370-30-11-14
kg
3.000
3.000
3.000
3.000
3.000
3.000
3.000
3.000
4.640
4.640
4.640
4.640
4.640
4.640
4.640
4.640
4.640
4.640
4.640
4.640
1SFL487002R1111
1SFL487002R1211
1SFL487002R1311
1SFL487002R1411
1SFL527002R1111
1SFL527002R1211
1SFL527002R1311
1SFL527002R1411
1SFL547002R1111
1SFL547002R1211
1SFL547002R1311
1SFL547002R1411
1SFL587002R1111
1SFL587002R1211
1SFL587002R1311
1SFL587002R1411
1SFL607002R1111
1SFL607002R1211
1SFL607002R1311
1SFL607002R1411
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
Main dimensions
mm, inches
A
SECTION B-B
180 7.09"
ø 10.5 0.41"
35.5 1.40"
5 0.20"
33.4 1.31"
94.7 3.73"
5 0.20"
43.75 1.72"
AF265, AF305, AF370
1SFC101091C0201 - Rev. D
225 8.86"
196 7.72"
35 1.38"
35.5 1.40"
29.5 1.16"
ø 8.5 0.33"
83.5 3.29"
105 4.13"
AF190, AF205
5/96 | ABB
140 5.51"
19.5 0.77"
152 5.98"
B
10 0.39"
10 0.39"
AF190 ... AF370 3-pole contactors with built-in PLC interface
90 to 200 kW
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
1SFC101165V0001
AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and
100...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-30-11
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
125
A
250
110
350
150
300
140
400
200
350
160
500
250
400
200
600
300
520
V 50/60 Hz
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
V DC
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
Auxiliary Type
contacts (1)
fitted
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
5
Pkg
(1 pce)
AF190-30-11-33
AF190-30-11-34
AF205-30-11-33
AF205-30-11-34
AF265-30-11-33
AF265-30-11-34
AF305-30-11-33
AF305-30-11-34
AF370-30-11-33
AF370-30-11-34
kg
3.000
3.000
3.000
3.000
4.640
4.640
4.640
4.640
4.640
4.640
1SFL487002R3311
1SFL487002R3411
1SFL527002R3311
1SFL527002R3411
1SFL547002R3311
1SFL547002R3411
1SFL587002R3311
1SFL587002R3411
1SFL607002R3311
1SFL607002R3411
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
AF190 ... AF370 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
Main dimensions
mm, inches
A
SECTION B-B
140 5.51"
19.5 0.77"
195.5 7.70"
ø 10.5 0.41"
35.5 1.40"
5 0.20"
5 0.20"
35 1.38"
AF190, AF205
1SFC101167C0201
225 8.86"
35.5 1.40"
33.4 1.31"
ø 8.5 0.33"
94.7 3.73"
105 4.13"
29.5 1.16"
10 0.39"
10 0.39"
169.5 6.67"
B
83.5 3.29"
AF370-30-11
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
90
275
196 7.72"
1SFC101133V0001
Ordering details
43.75 1.72"
AF265, AF305, AF370
ABB | 5/97
AF116 ... AF370 3-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
Main accessories
Main accessories
(other accessories available)
CAL19-11B
2-pole auxiliary
contact block
LW
Terminal
enlargement
VM
Mechanical
interlock
5
AF contactor
with bar connections
LT
Terminal shroud
CAL19-11B
2-pole auxiliary
contact block
AF contactor
with built-in cable clamps
TF/TA
Thermal overload relay
EF
Electronic overload relay
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL19-11
AF116 ... AF370
3 0
1 1
1 x CAL19-11
+
2 x CAL19-11B
AF116 ... AF370
3 0
1 1
–
+
2 x CAL19-11B (1)
(1) Total number of auxiliary contact blocks for the two contactors.
Mechanical interlock units
CAL19-11B
(between two contactors)
–
+
VM... (2)
(2) Interlock type, according to the contactor ratings (see "Accessories").
Contactor types
AF116 ... AF140
AF146
AF190, AF205
AF265 ... AF370
Thermal overload relays
TF140DU (66...142 A)
–
TA200DU (66...200 A)
–
Electronic overload relays
EF146 (54...150 A)
EF146 (54...150 A)
EF205 (63...210 A)
EF370 (115...380 A)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
(1) Direct mounting - No kit required.
5/98 | ABB
1SFC101132C0201
Overload relays fitting details (1)
AF116 ... AF370 3-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
Main accessories
Ordering details (1)
For contactors
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
1SFC101071V0001
kg
Side-mounted instantaneous auxiliary contact blocks
AF116 ... AF370
1
1 CAL19-11
1
1 CAL19-11B
1SFN010820R1011
1SFN010820R3311
2
2
0.050
0.050
Mechanical interlock unit
AF116 ... AF370
AF116 ... AF146 and AF190, AF205
AF190, AF205 and AF265 ... AF370
VM19
VM140/190
VM205/265
1SFN030300R1000
1SFN034403R1000
1SFN035203R1000
1
1
1
0.054
0.088
0.090
LT140-30L
LT205-30C
LT205-30L
LT205-30Y
1SFN124203R1000
1SFN124801R1000
1SFN124803R1000
1SFN124804R1000
2
2
2
1
0.070
0.050
0.220
0.050
LT370-30C
LT370-30L
LT370-30Y
1SFN125401R1000
1SFN125403R1000
1SFN125404R1000
2
2
1
0.035
0.280
0.075
LT370-30D
1SFN125406R1000
1
0.150
Type
Order code
Pkg
Weight
qty
(1 pce)
kg
CAL19-11
1SFC101041V0001
VM19
For contactors
bar
mm
Terminal enlargements
AF116...AF146
AF190...AF205
AF265...AF370
6.5
10.5
10.5
13 x 3
17.5 x 5
20 x 5
LW140
LW205
LW370
1SFN074207R1000
1SFN074807R1000
1SFN075407R1000
1
1
1
0.115
0.260
0.340
Terminal extension
AF116...AF146
AF190...AF250
AF265...AF370
6.5
8.5
10.5
13 x 3
17.5 x 5
20 x 5
LX140
LX205
LX370
1SFN074210R1000
1SFN074810R1000
1SFN075410R1000
1
1
1
0.072
0.180
0.234
1SFC101049V0001
LT370-30C
LX140
Dimensions
hole Ø
mm
5
(1) For more information, refer to main catalog "Accessories" section.
1SFC101138C0201
1SFC101035V0001
Terminal shrouds
AF116 ... AF146, with compression lugs
AF190, AF205, with cable clamps
AF190, AF205, with compression lugs
AF190, AF205, with shorting bar or between contactor
and TOL/EOL in DOL-starters
AF265 ... AF370, with cable clamps
AF265 ... AF370, with compression lugs
AF265 ... AF370, with shorting bar or between contactor
and TOL/EOL in DOL-starters
AF265 ... AF370, for use with extending cable clamps,
ATK300/2 and OZXB4
ABB | 5/99
AF400 ... AF750 3-pole contactors
200 to 400 kW
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
1SFC101022V0001
AF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC or 600 V DC (2). These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and
24...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF460-30-11
Ordering details
1SFC101025V0001
5
AF750-30-11
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
690 V
AC-3
AC-1
kW
A
200
600
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc min. ... Uc max.
use
rating
600 V AC
hp
350
A
550
250
700
400
650
315
800
500
750
400
1050
600
900
V 50/60 Hz
48…130
100…250
250…500
48…130
100…250
250…500
48…130
100…250
250…500
48…130
100…250
250…500
Auxiliary Type
contacts
fitted
V DC
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
Pkg
(1 pce)
AF400-30-11
AF400-30-11
AF400-30-11
AF400-30-11
AF460-30-11
AF460-30-11
AF460-30-11
AF460-30-11
AF580-30-11
AF580-30-11
AF580-30-11
AF580-30-11
AF750-30-11
AF750-30-11
AF750-30-11
AF750-30-11
kg
12.000
12.000
12.000
12.000
12.000
12.000
12.000
12.000
15.000
15.000
15.000
15.000
15.000
15.000
15.000
15.000
1SFL577001R6811 (1)
1SFL577001R6911
1SFL577001R7011
1SFL577001R7111
1SFL597001R6811 (1)
1SFL597001R6911
1SFL597001R7011
1SFL597001R7111
1SFL617001R6811 (1)
1SFL617001R6911
1SFL617001R7011
1SFL617001R7111
1SFL637001R6811 (1)
1SFL637001R6911
1SFL637001R7011
1SFL637001R7111
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
(2) Up to 850 V DC for AF580, AF750.
AF400 ... AF750 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
mm, inches
242 9.53"
48.5 1.91"
6 0.24"
72 2.83"
AF580, AF750
E1633D
1SFC101013C0201 - Rev. A
E1627D1
278 10.94"
E1626D1
22.5 0.89" ø6.5 0.26" ø12.5 0.49"
40 1.57"
6
0.24"
11.5 0.45"
48.5
1.91"
273 10.75"
ø 10.5
0.41"
268 10.55"
63 2.48"
AF400, AF460
5/100 | ABB
210 8.27"
216 8.5"
ø 6.5
0.26"
11.5
0.45"
22.5
0.89"
25
0.98"
283 11.14"
186 7.32"
E1632D
Main dimensions
AF1250 ... AF2650 3-pole contactors
475 to 560 kW and 1260 to 2650 A AC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
1SFC101027V0001
AF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC,
AF2650 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main
poles.
– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
- only 4 coils for AF1250 to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC
- only 1 coil for AF1350 ... AF2650 to cover control voltages between 100...250 V 50/60 Hz and
100...250 V DC
- can manage large control voltage variations
- reduced panel energy consumption
- very distinct closing and opening
- can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).
– built-in surge suppression
– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF1250-30-11
UL/CSA
3-phase
motor
rating
480 V
475
560
-
800
900
-
1350
1650
2050
2650
hp
-
Rated control circuit
voltage
Uc
(1)
General
use
rating
600 V AC
(2)
A
V 50/60 Hz
1210
48…130
100…250
250…500
1350
100…250
1650
100…250
2100
100…250
2700
100...250
Auxiliary Type
contacts
fitted
V DC
24…60
48…130
100…250
250…500
100…250
100…250
100…250
100...250
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order code
5
Weight
Pkg
(1 pce)
AF1250-30-11
AF1250-30-11
AF1250-30-11
AF1250-30-11
AF1350-30-11
AF1650-30-11
AF2050-30-11
AF2650-30-11
kg
16.000
16.000
16.000
16.000
34.000
35.000
35.000
45.000
1SFL647001R6811 (1)
1SFL647001R6911
1SFL647001R7011
1SFL647001R7111
1SFL657001R7011
1SFL677001R7011
1SFL707001R7011
1SFL667001R7011
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
(2) AF2650: Maximum operational voltage = 1000 V according to UL / CSA.
AF1250 ... AF2650 are equipped with low voltage inputs for control, for example by a PLC
Control inputs
AF1350, AF1650, AF2050
392 mm / 15.43"
47 mm / 1.85"
10 mm / 0.39"
A
B
C
mm, inches
40 1.57"
27
ø 13
0.51"
1.06"
13 0.51"
30 1.18"
10 0.39"
ø 7 0.28"
13
0.51"
AF1350, AF1650
AF1250
40 1.57"
10 0.39"
AF2650
244 9.61"
136 5.35"
312 12.3"
A
1SFC101125F0001
C
80
3.15"
101
3.98"
136 5.35"
ø 9 0.35"
438 17.24"
AF1350, AF1650, AF2050, AF2650
ABB | 5/101
1SFC101094C0201 - Rev. A
72 2.83"
210 8.27"
1SFC101124F0001
72 2.83"
8 0.31"
17 0.67"
B
249 9.8"
263 10.35"
ø7 0.28"
46.5
18.3"
40
1.57"
30 1.18"
AF2050
136 5.35"
242 9.53"
ø 13
0.51"
17 0.67"
40
72 2.83"
40
1.57"
17 0.67"
50 1.97"
27
AF2650
422 mm / 16.61"
53 mm / 2.09"
25 mm / 0.98"
1.57"
Main dimensions
313 12.32"
AF2650-30-11
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
690 V
AC-3
AC-1
kW
A
1260
344 13.54"
1SFC101031V0001
Ordering details
AF400 ... AF2650 3-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
Main accessories
Main accessories
(other accessories available)
LW
Terminal
enlargement
LZ
Connector
terminal
CAL18-11B
2-pole auxiliary
contact block
5
VM
Mechanical
interlock
LT
Terminal shroud
AF contactor
CAL18-11B
2-pole auxiliary
contact block
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
Mechanical interlock units
CAL18-11B (3)
CAL18-11
(between two contactors)
Contactors + auxiliary contact blocks
AF400 ... AF2650
3 0
1 1
1 x CAL18-11
+
2 x CAL18-11B
–
Contactors with mechanical interlocking + auxiliary contact blocks
AF400 ... AF2650
3 0
1 1
2 x CAL18-11 (1)
+
4 x CAL18-11B (1)
+
VM...H (2)
Overload relays fitting details
Contactor types
AF400, AF460
AF580, AF750
AF1350, AF1650
Thermal overload relays
–
–
–
Electronic overload relays
EF460 (150...500 A) (4)
EF750 (250...800 A) (4)
E1250DU (375...1250 A) (4)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
(4) Mounting kit required (see "Motor protection").
5/102 | ABB
1SFC101126C0201 - Rev. A
(1) Total number of auxiliary contact blocks for the two contactors.
(2) Interlock type, according to the contactor ratings (see "Accessories").
(3) The CEL18-.. auxiliary contact blocks can replace the CAL18-11 and CAL18-11B. Though, no auxiliary contact block can be mounted outside the CEL18-..
AF400 ... AF2650 3-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
Main accessories
Ordering details (1)
Auxiliary
contacts
1SFC101082V0001
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
1SFC101089V0001
VM750H
Side-mounted instantaneous auxiliary contact blocks
AF400 ... AF2650
1
1 CAL18-11
1
1 CAL18-11B
1SFN010720R1011
1SFN010720R3311
2
2
0.050
0.050
Mechanical interlock unit
AF400 ... AF1250
AF1350 ... AF2650
VM750H
VM1650H
1SFN035700R1000
1SFN036503R1000
1
1
0.200
6.000
Terminal shrouds
AF400, AF460 with connectors
AF400, AF460 with lugs
AF580 ... AF750 with connectors
AF580 ... AF750 with lugs
LT460-AC
LT460-AL
LT750-AC
LT750-AL
1SFN125701R1000
1SFN125703R1000
1SFN126101R1000
1SFN126103R1000
2
2
2
2
0.100
0.800
0.120
0.825
Type
Order code
Pkg
Weight
qty
(1 pce)
kg
For contactors
Dimensions
hole Ø
mm
bar
mm
Terminal enlargements
AF400, AF460
AF580, AF750
AF1250
10.5
13
13
25 x 5
40 x 6
50 x 10
LW460
LW750
LW1250
1SFN075707R1000
1SFN076107R1000
1SFN076407R1000
1
1
1
0.730
1.230
2.000
Terminal extension
AF400, AF460
AF580, AF750
10.5
13
25 x 5
40 x 6
LX460
LX750
1SFN075710R1000
1SFN076110R1000
1
1
0.500
0.850
LT460-AC
5
(1) For more information, refer to main catalog "Accessories" section.
1SFC101128C0201
1SFC101084V0001
CAL18-11
ABB | 5/103
AF09 ... AF38 2-stack 3-pole contactors
4 to 18.5 kW
AC / DC operated
1SBC101002V0014
Description
AF09-30-22
AF09 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):
–– 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
1SBC101003V0014
5
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
25
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc min. … Uc max.
rating
600 V AC
hp
5
A
25
5.5
28
7.5
28
7.5
30
10
30
11
45
15
45
1SBC101004V0014
AF26-30-11
AF26-30-22
15
50
18.5
50
20
50
25
50
Auxiliary Type
contacts (1)
fitted
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
V DC
(2)
48...130
100...250
250...500
(2)
48...130
100...250
250...500
(2)
48...130
100...250
250...500
(2)
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
48...130
48...130
100...250
100...250
250...500
250...500
(2)
(2)
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Order code
Weight
Pkg
(1 pce)
AF09-30-22-41
AF09-30-22-12
AF09-30-22-13
AF09-30-22-14
AF12-30-22-41
AF12-30-22-12
AF12-30-22-13
AF12-30-22-14
AF16-30-22-41
AF16-30-22-12
AF16-30-22-13
AF16-30-22-14
AF26-30-11-41
AF26-30-22-41
AF26-30-11-12
AF26-30-22-12
AF26-30-11-13
AF26-30-22-13
AF26-30-11-14
AF26-30-22-14
AF30-30-11-41
AF30-30-22-41
AF30-30-11-12
AF30-30-22-12
AF30-30-11-13
AF30-30-22-13
AF30-30-11-14
AF30-30-22-14
AF38-30-11-41
AF38-30-22-41
AF38-30-11-12
AF38-30-22-12
AF38-30-11-13
AF38-30-22-13
AF38-30-11-14
AF38-30-22-14
1SBL137001R4122
1SBL137001R1222
1SBL137001R1322
1SBL137001R1422
1SBL157001R4122
1SBL157001R1222
1SBL157001R1322
1SBL157001R1422
1SBL177001R4122
1SBL177001R1222
1SBL177001R1322
1SBL177001R1422
1SBL237001R4111
1SBL237001R4122
1SBL237001R1211
1SBL237001R1222
1SBL237001R1311
1SBL237001R1322
1SBL237001R1411
1SBL237001R1422
1SBL277001R4111
1SBL277001R4122
1SBL277001R1211
1SBL277001R1222
1SBL277001R1311
1SBL277001R1322
1SBL277001R1411
1SBL277001R1422
1SBL297001R4111
1SBL297001R4122
1SBL297001R1211
1SBL297001R1222
1SBL297001R1311
1SBL297001R1322
1SBL297001R1411
1SBL297001R1422
kg
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.350
0.360
0.350
0.360
0.350
0.360
0.390
0.400
0.350
0.360
0.350
0.360
0.350
0.360
0.390
0.400
0.350
0.360
0.350
0.360
0.350
0.360
0.390
0.400
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
(2) For 24...60 V 50/60 Hz - 20...60 V DC, use AF..-30-..-11 (see voltage code table).
AF..-30-..-11 not suitable for direct control by PLC-output.
110.5 4.35"
45
35 1.77"
1.38"
AF09, AF12, AF16
5/104 | ABB
60 2.36" 6 0.24"
80 3.15"
5.5 0.22"
ø 4.2 0.17"
43 1.69"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
119.5 4.70"
AF..-30-11
111.5 4.39"
80 3.15"
2x
M4 8-32 UNC5.5 0.22"
70 2.76"
10 0.39"
5 0.20"
AF26, AF30,
AF38
5 0.20"
35 mm EN/IEC 60715
71 2.80"
45 1.77"
AF..-30-22
5.5 0.22"
10 0.39"
1SBC101373S0201 - Rev. B
mm, inches
43 1.69"
Main dimensions
AF09Z ... AF38Z 2-stack 3-pole contactors
4 to 18.5 kW
AC / DC operated - Low consumption
1SBC101002V0014
Description
AF09Z-30-22
AF09Z ... AF38Z contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):
–– 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and
12...250 V DC
-- can manage large control voltage variations, allow direct control by PLC-output ≥ 24 V DC 500 mA,
reduced panel energy consumption, very distinct closing and opening,
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc min. … Uc max.
rating
600 V AC
hp
5
A
25
5.5
28
7.5
28
7.5
30
10
30
11
45
15
45
1SBC101004V0014
15
50
18.5
50
20
50
25
50
V 50/60 Hz
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
-
V DC
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
24...60
20...60
48...130
48...130
100...250
100...250
-
12...20
24...60
20...60
48...130
48...130
100...250
100...250
-
12...20
24...60
20...60
48...130
48...130
100...250
100...250
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Order code
Weight
5
Pkg
(1 pce)
AF09Z-30-22-20
AF09Z-30-22-21
AF09Z-30-22-22
AF09Z-30-22-23
AF12Z-30-22-20
AF12Z-30-22-21
AF12Z-30-22-22
AF12Z-30-22-23
AF16Z-30-22-20
AF16Z-30-22-21
AF16Z-30-22-22
AF16Z-30-22-23
AF26Z-30-11-20
AF26Z-30-22-20
AF26Z-30-11-21
AF26Z-30-22-21
AF26Z-30-11-22
AF26Z-30-22-22
AF26Z-30-11-23
AF26Z-30-22-23
AF30Z-30-11-20
AF30Z-30-22-20
AF30Z-30-11-21
AF30Z-30-22-21
AF30Z-30-11-22
AF30Z-30-22-22
AF30Z-30-11-23
AF30Z-30-22-23
AF38Z-30-11-20
AF38Z-30-22-20
AF38Z-30-11-21
AF38Z-30-22-21
AF38Z-30-11-22
AF38Z-30-22-22
AF38Z-30-11-23
AF38Z-30-22-23
kg
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
0.390
0.400
1SBL136001R2022
1SBL136001R2122
1SBL136001R2222
1SBL136001R2322
1SBL156001R2022
1SBL156001R2122
1SBL156001R2222
1SBL156001R2322
1SBL176001R2022
1SBL176001R2122
1SBL176001R2222
1SBL176001R2322
1SBL236001R2011
1SBL236001R2022
1SBL236001R2111
1SBL236001R2122
1SBL236001R2211
1SBL236001R2222
1SBL236001R2311
1SBL236001R2322
1SBL276001R2011
1SBL276001R2022
1SBL276001R2111
1SBL276001R2122
1SBL276001R2211
1SBL276001R2222
1SBL276001R2311
1SBL276001R2322
1SBL296001R2011
1SBL296001R2022
1SBL296001R2111
1SBL296001R2122
1SBL296001R2211
1SBL296001R2222
1SBL296001R2311
1SBL296001R2322
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil
terminals: A1+ for the positive pole and A2- for the negative pole
mm, inches
10 0.39"
35
45 1.38"
1.77"
AF09Z, AF12Z, AF16Z
ø 4.2 0.17"
6 0.24"
5.5 0.22"
70 2.76"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
119.5 4.70"
AF..-30-11
111.5 4.39"
80 3.15"
2x
M4 8-32 UNC 5.5 0.22"
5 0.20"
35 mm EN/IEC 60715
71 2.80"
45 1.77"
AF..-30-22
5.5 0.22"
10 0.39"
5 0.20"
AF26Z, AF30Z, AF38Z
ABB | 5/105
1SBC101374S0201 - Rev. B
110.5 4.35"
43 1.69"
Main dimensions
80 3.15"
AF26Z-30-22
Auxiliary Type
contacts (1)
fitted
80 3.15"
60 2.36"
AF26Z-30-11
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
25
43 1.69"
1SBC101003V0014
Ordering details
AF40 ... AF65 2-stack 3-pole contactors
18.5 to 30 kW
AC / DC operated
Description
1SBC101005V0014
AF40 ... AF65 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):
–– 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF40-30-11
5
Ordering details
1SBC101006V0014
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
18.5
70
UL / CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc min. … Uc max.
use
rating
600 V AC
hp
30
A
60
AF40-30-22
22
30
100
105
40
80
50
90
Auxiliary Type
contacts (1)
fitted
V 50/60 Hz
24...60
V DC
-
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
(2)
(2)
(2)
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Order code
Weight
Pkg
(1 pce)
AF40-30-11-41
AF40-30-22-41
AF40-30-11-11
AF40-30-22-11
AF40-30-11-12
AF40-30-22-12
AF40-30-11-13
AF40-30-22-13
AF40-30-11-14
AF40-30-22-14
AF52-30-11-41
AF52-30-22-41
AF52-30-11-11
AF52-30-22-11
AF52-30-11-12
AF52-30-22-12
AF52-30-11-13
AF52-30-22-13
AF52-30-11-14
AF52-30-22-14
AF65-30-11-41
AF65-30-22-41
AF65-30-11-11
AF65-30-22-11
AF65-30-11-12
AF65-30-22-12
AF65-30-11-13
AF65-30-22-13
AF65-30-11-14
AF65-30-22-14
1SBL347001R4111
1SBL347001R4122
1SBL347001R1111
1SBL347001R1122
1SBL347001R1211
1SBL347001R1222
1SBL347001R1311
1SBL347001R1322
1SBL347001R1411
1SBL347001R1422
1SBL367001R4111
1SBL367001R4122
1SBL367001R1111
1SBL367001R1122
1SBL367001R1211
1SBL367001R1222
1SBL367001R1311
1SBL367001R1322
1SBL367001R1411
1SBL367001R1422
1SBL387001R4111
1SBL387001R4122
1SBL387001R1111
1SBL387001R1122
1SBL387001R1211
1SBL387001R1222
1SBL387001R1311
1SBL387001R1322
1SBL387001R1411
1SBL387001R1422
kg
1.010
1.020
1.010
1.020
1.010
1.020
0.990
1.000
0.990
1.000
1.010
1.020
1.010
1.020
1.010
1.020
0.990
1.000
0.990
1.000
1.010
1.020
1.010
1.020
1.010
1.020
0.990
1.000
0.990
1.000
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
(2) AF..-30-..-11 not suitable for direct control by PLC-output.
mm, inches
144 144
5.67"
5.67"
111
1114.37"
4.37"
7 70.28"
0.28"
111 111
4.37"
4.37"
5/106 | ABB
AF40, AF52, AF65-30-22-..
43 1.69"
1SBC101741S0201 - Rev. A
6 0.24"
5.5 5.5
0.22"
0.22"
10100.39"
0.39"
AF40, AF52, AF65-30-11-..
10 0.39"
10 0.39"
7 0.28"
7 0.28"
35 mm EN/IEC 60715
119.5 4.70"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
119.5 4.70"
119.5 4.70"
5.5
5.50.22"
0.22"
119.5 4.70"
6 0.24"
6 0.24"
6 0.24"
55 2.17"
55 2.17"
35 mm EN/IEC 60715
55552.17"
2.17"
43 1.69"
Main dimensions
12120.47"
0.47"
AF80 ... AF96 2-stack 3-pole contactors
37 to 45 kW
AC / DC operated
1SBC101017V0014
Description
AF80-30-11
AF80 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):
–– 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
5
Ordering details
IEC
General
use
rating
600 V AC
A
105
1SBC101007V0014
UL / CSA
Rated operational 3-phase
power
current motor
θ ≤ 40 °C rating
480 V
400 V
AC-3
AC-1
kW
A
hp
37
125
60
AF80-30-22
45
130
60
115
Rated control circuit
voltage
Uc min. … Uc max.
Auxiliary Type
contacts (1)
fitted
V 50/60 Hz
24...60
V DC
-
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
(2)
(2)
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Order code
Weight
Pkg
(1 pce)
AF80-30-11-41
AF80-30-22-41
AF80-30-11-11
AF80-30-22-11
AF80-30-11-12
AF80-30-22-12
AF80-30-11-13
AF80-30-22-13
AF80-30-11-14
AF80-30-22-14
AF96-30-11-41
AF96-30-22-41
AF96-30-11-11
AF96-30-22-11
AF96-30-11-12
AF96-30-22-12
AF96-30-11-13
AF96-30-22-13
AF96-30-11-14
AF96-30-22-14
kg
1.260
1.270
1.260
1.270
1.260
1.270
1.210
1.220
1.210
1.220
1.260
1.270
1.260
1.270
1.260
1.270
1.210
1.220
1.210
1.220
1SBL397001R4111
1SBL397001R4122
1SBL397001R1111
1SBL397001R1122
1SBL397001R1211
1SBL397001R1222
1SBL397001R1311
1SBL397001R1322
1SBL397001R1411
1SBL397001R1422
1SBL407001R4111
1SBL407001R4122
1SBL407001R1111
1SBL407001R1122
1SBL407001R1211
1SBL407001R1222
1SBL407001R1311
1SBL407001R1322
1SBL407001R1411
1SBL407001R1422
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
(2) AF..-30-..-11 not suitable for direct control by PLC-output.
mm, inches
149 5.87"149 5.87"
116 4.57"
116 4.57"
70 2.76" 70 2.76"
10
10
0.39"
0.39"
10 0.39"
10 0.39"
AF80, AF96-30-11-..
AF80, AF96-30-22-..
ABB | 5/107
43 1.69"
5.5 0.22"5.5 0.22"
1SBC101742S0201 - Rev. A
6 0.24"
35 x 15 mm EN/IEC 60715
119.5 4.70"
35 x 15 mm EN/IEC 60715
35 x 15 mm EN/IEC 60715
119.5 4.70"
119.5 4.70"
5.5 0.22"
5.5 0.22"
116 4.57"116 4.57"
7 0.28" 7 0.28"
119.5 4.70"
6 0.24"
6 0.24"
6 0.24"
7 0.28"7 0.28"
35 x 15 mm EN/IEC 60715
70 2.76"
70 2.76"
43 1.69"
Main dimensions
12 0.47"
12 0.47"
AF09 ... AF96 2-stack 3-pole contactors
Main accessories
Contactor and main accessories (other accessories available)
AF09 ... AF96-30-22
AF26 ... AF38-30-11
AF 2-stack
contactor
5
BX4-CA
Protective cover
CAL4-11
2-pole auxiliary
contact block
TF42
EF
Overload relay
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Built-in
Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
Main
poles
Electronic
timer
1-pole CA4
1-pole CC4
AF26
AF40
AF80
AF09
AF40
...
...
...
...
...
AF38
AF65
AF96
AF96
AF96
3
3
3
3
3
0
0
0
0
0
1
1
1
2
2
1
1
1
2
2
–
4 max.
4 max.
–
–
2-pole CAT4-11
–
or 1
–
–
–
4-pole CA4
–
or 1
or 1
–
–
TEF4
–
or 1
or 1
–
–
Electrical and
mechanical interlock set
Side-mounted accessories
Auxiliary contact blocks
(between 2 contactors)
Left side
VEM4
2-pole CAL4-11
–
–
–
–
–
+ 1
–
–
+ 1
+ 1
Right side
+ 1
+ 1
+ 1
–
+ 1
Overload relays fitting details (1)
Contactor types
AF09 ... AF38
AF26 ... AF38
AF40 ... AF65
AF80, AF96
Thermal overload relays
TF42 (0.10...38 A)
TF42 (0.10...38 A)
TF65 (22...67 A)
TF96 (40...96 A)
Electronic overload relays
EF19 (0.10...19 A)
EF45 (9...45 A)
EF65 (20...70 A)
EF96 (36...100 A)
1SBC101750S0201 - Rev. A
The addition of an overload relay on the contactor does not prevent fitting of many other accessories as shown above.
(1) Direct mounting - No kit required.
5/108 | ABB
AF09 ... AF96 2-stack 3-pole contactors
Main accessories
Ordering Details (1)
1SBC100007V0014
For contactors
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
1SBC100010V0014
kg
CAL4-11
Side-mounted instantaneous auxiliary contact blocks
AF09 ... AF96
1 1
– –
CAL4-11
1 1
– –
CAL4-11-T
1SBN010120R1011
1SBN010120T1011
1
10
0.040
0.040
Mechanical interlock unit
AF09 ... AF38
AF40 ... AF96
1SBN030105T1000
1SBN033405T1000
10
10
0.005
0.006
Pkg
qty
Weight
(1 pce)
VM4
VM96-4
Note: VM4 and VM96-4 include 2 fixing clips (BB4) to maintain together both contactors.
VM4
1SBC100014V0014
For contactors
Time delay
range
Delay
type
Auxiliary Type
contacts
Order code
selected by
switch
Electronic timers
AF40 ... AF96-30-11 0.1...1 s
1...10 s
10...100 s
BEA16-4
5
kg
ON-delay
1 1
TEF4-ON
1SBN020112R1000
1
0.065
OFF-delay
1 1
TEF4-OFF
1SBN020114R1000
1
0.065
BEA16-4
1SBN081306T1000
10
0.025
BEA26-4
1SBN082306T1000
10
0.025
BEA38-4
1SBN082306T2000
10
0.030
Connection sets for reversing contactors
AF09 ... AF16
AF26 ... AF38
AF40 ... AF65
AF80 ... AF96
BER16-4
BER38-4
BER65-4
BER96-4
1SBN081311R1000
1SBN082311R1000
1SBN083411R1000
1SBN083911R1000
1
1
1
1
0.045
0.100
0.175
0.250
Connection sets for star-delta starting
AF09 ... AF16
with or without VM4
AF26 ... AF38
with or without VM4
AF40 ... AF65
with or without VM96-4
AF80 ... AF96
with or without VM96-4
BEY16-4
BEY38-4
BEY65-4
BEY96-4
1SBN081313R2000
1SBN082713R2000
1SBN083413R2000
1SBN083913R2000
1
1
1
1
0.050
0.110
0.200
0.250
1SBC100004V0014
Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.
1SBC100016V0014
TEF4-ON
BER16-4
Connecting links with manual motor starters
AF09 ... AF16
with MS116-0.16 … MS116-25,
MS132-0.16 … MS132-25
AF26 ... AF38
with MS116-0.16 … MS116-16,
MS132-0.16 ... MS132-10
with MS116-20 … MS116-32,
MS132-12 ... MS132-32
1SBC100018V0014
(1) For more information, refer to "Accessories" section.
1SBC101751S0201
BEY16-4
ABB | 5/109
AF116 ... AF146 3-pole contactors
55 to 75 kW
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
1SFC101009V0001
Description
AF146-30-22
AF116 ... AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC, AF146 up to 1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
1SFC101010V0001
5
AF146-30-22B
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
A
160
75
200
100
200
75
225
100
200
Order code
Weight
Pkg
(1 pce)
V 50/60 Hz V DC
For connection with built-in cable clamps
55
75
24...60
20...60
160
160
48...130 48...130
100...250 100...250
250...500 250...500
75
100
24...60
20...60
200
200
48...130 48...130
100...250 100...250
250...500 250...500
75
100
24...60
20...60
225
200
48...130 48...130
100...250 100...250
250...500 250...500
With bar connections
55
75
160
Auxiliary Type
contacts (1)
fitted
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
kg
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AF116-30-22-11
AF116-30-22-12
AF116-30-22-13
AF116-30-22-14
AF140-30-22-11
AF140-30-22-12
AF140-30-22-13
AF140-30-22-13
AF146-30-22-11
AF146-30-22-12
AF146-30-22-13
AF146-30-22-14
1SFL427001R1122
1SFL427001R1222
1SFL427001R1322
1SFL427001R1422
1SFL447001R1122
1SFL447001R1222
1SFL447001R1322
1SFL447001R1422
1SFL467001R1122
1SFL467001R1222
1SFL467001R1322
1SFL467001R1422
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
1.750
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AF116-30-22B-11
AF116-30-22B-12
AF116-30-22B-13
AF116-30-22B-14
AF140-30-22B-11
AF140-30-22B-12
AF140-30-22B-13
AF140-30-22B-14
AF146-30-22B-11
AF146-30-22B-12
AF146-30-22B-13
AF146-30-22B-14
1SFL427002R1122
1SFL427002R1222
1SFL427002R1322
1SFL427002R1422
1SFL447002R1122
1SFL447002R1222
1SFL447002R1322
1SFL447002R1422
1SFL467002R1122
1SFL467002R1222
1SFL467002R1322
1SFL467002R1422
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
1.500
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
mm, inches
30 1.18"
AF116, AF140, AF146-30-22
5/110 | ABB
SECTION E-E
E
90 3.54"
D
126 4.96"
D
30 1.18"
AF116, AF140, AF146-30-22B
19.5 0.77"
10 0.39"
150 5.91"
150 5.91"
D
19.5 4.96"
D
126 4.96"
1SFC101092C0201 - Rev. C
SECTION E-E
90 3.54"
55.5 0.22"
10 0.39"
E
55.5 2.18"
Main dimensions
AF116 ... AF146 3-pole contactors with built-in PLC interface
55 to 75 kW
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
1SFC101184V0001
Description
AF146-30-22
AF116 ... AF146 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC, AF146 up to 1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and
100...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
A
Auxiliary Type
contacts (1)
fitted
Order code
Weight
5
Pkg
(1 pce)
V 50/60 Hz V DC
kg
160
75
160
75
200
100
200
75
225
100
200
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
2
2
2
2
2
2
2
2
2
2
2
2
AF116-30-22-33
AF116-30-22-34
AF140-30-22-33
AF140-30-22-33
AF146-30-22-33
AF146-30-22-34
1SFL427001R3322
1SFL427001R3422
1SFL447001R3322
1SFL447001R3422
1SFL467001R3322
1SFL467001R3422
1.750
1.750
1.750
1.750
1.750
1.750
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
2
2
2
2
2
2
2
2
2
2
2
2
AF116-30-22B-33
AF116-30-22B-34
AF140-30-22B-33
AF140-30-22B-34
AF146-30-22B-33
AF146-30-22B-34
1SFL427002R3322
1SFL427002R3422
1SFL447002R3322
1SFL447002R3422
1SFL467002R3322
1SFL467002R3422
1.500
1.500
1.500
1.500
1.500
1.500
With bar connections
55
160
75
160
75
200
100
200
75
225
100
200
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
AF116 ... AF146 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
mm, inches
142.5 5.61"
E
90 3.54"
D
D
19.5 4.96"
10 0.39"
D
150 5.91"
D
30 1.18"
AF116, AF140, AF146-30-22
142.5 5.61"
1SFC101168C0201
90 3.54"
19.5 0.77"
10 0.39"
55.5 2.18"
Main dimensions
55.5 0.22"
AF146-30-22B
55
150 5.91"
1SFC101187V0001
For connection with built-in cable clamps
30 1.18"
AF116, AF140, AF146-30-22B
ABB | 5/111
AF190 ... AF370 3-pole contactors
90 to 200 kW
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
Description
1SFC101014V0001
AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-30-22
Ordering details
1SFC101020V0001
5
AF370-30-22
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
90
275
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
125
A
250
110
350
150
300
140
400
200
350
160
500
250
400
200
600
300
520
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
V DC
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
Auxiliary Type
contacts (1)
fitted
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Order code
Weight
Pkg
(1 pce)
AF190-30-22-11
AF190-30-22-12
AF190-30-22-13
AF190-30-22-14
AF205-30-22-11
AF205-30-22-12
AF205-30-22-13
AF205-30-22-14
AF265-30-22-11
AF265-30-22-12
AF265-30-22-13
AF265-30-22-14
AF305-30-22-11
AF305-30-22-12
AF305-30-22-13
AF305-30-22-14
AF370-30-22-11
AF370-30-22-12
AF370-30-22-13
AF370-30-22-14
kg
3.000
3.000
3.000
3.000
3.000
3.000
3.000
3.000
4.675
4.675
4.675
4.675
4.675
4.675
4.675
4.675
4.675
4.675
4.675
4.675
1SFL487002R1122
1SFL487002R1222
1SFL487002R1322
1SFL487002R1422
1SFL527002R1122
1SFL527002R1222
1SFL527002R1322
1SFL527002R1422
1SFL547002R1122
1SFL547002R1222
1SFL547002R1322
1SFL547002R1422
1SFL587002R1122
1SFL587002R1222
1SFL587002R1322
1SFL587002R1422
1SFL607002R1122
1SFL607002R1222
1SFL607002R1322
1SFL607002R1422
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
Main dimensions
mm, inches
A
SECTION B-B
180 7.09"
ø 10.5 0.41"
35.5 1.40"
5 0.20"
1SFC101093C0201 - Rev. D
43.75 1.72"
AF265, AF305, AF370
33.4 1.31"
94.7 3.73"
225 8.86"
196 7.72"
35 1.38"
5 0.20"
29.5 1.16"
35.5 1.40"
ø 8.5 0.33"
83.5 3.29"
105 4.13"
AF190, AF205
5/112 | ABB
140 5.51"
19.5 0.77"
152 5.98"
B
10 0.39"
10 0.39"
AF190 ... AF370 3-pole contactors with built-in PLC interface
90 to 200 kW
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
Description
1SFC101181V0001
AF190 ... AF370 contactors are mainly used for controlling 3-phase motors and power circuits up to
1000 V AC. These contactors are of the block type design with 3 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 2 coils to cover control voltages between 100...500 V 50/60 Hz and
100...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-30-22
UL / CSA
3-phase
motor
rating
480 V
Rated control
General circuit
voltage
use
Uc min. ... Uc max.
rating
600 V AC
hp
125
A
250
110
350
150
300
140
400
200
350
160
500
250
400
200
600
300
520
V 50/60 Hz
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
V DC
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
100...250
250...500
Auxiliary Type
contacts (1)
fitted
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Order code
Weight
5
Pkg
(1 pce)
AF190-30-22-33
AF190-30-22-34
AF205-30-22-33
AF205-30-22-34
AF265-30-22-33
AF265-30-22-34
AF305-30-22-33
AF305-30-22-34
AF370-30-22-33
AF370-30-22-34
kg
3.000
3.000
3.000
3.000
4.675
4.675
4.675
4.675
4.675
4.675
1SFL487002R3322
1SFL487002R3422
1SFL527002R3322
1SFL527002R3422
1SFL547002R3322
1SFL547002R3422
1SFL587002R3322
1SFL587002R3422
1SFL607002R3322
1SFL607002R3422
(1) For other auxiliary contacts arrangements, please contact your ABB local sales organization.
AF190 ... AF370 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
Main dimensions
mm, inches
A
SECTION B-B
140 5.51"
19.5 0.77"
195.5 7.70"
ø 10.5 0.41"
35.5 1.40"
5 0.20"
5 0.20"
35 1.38"
AF190, AF205
1SFC101169C0201
225 8.86"
35.5 1.40"
33.4 1.31"
ø 8.5 0.33"
94.7 3.73"
105 4.13"
29.5 1.16"
10 0.39"
10 0.39"
169.5 6.67"
B
83.5 3.29"
AF370-30-22
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
90
275
196 7.72"
1SFC101169V0001
Ordering details
43.75 1.72"
AF265, AF305, AF370
ABB | 5/113
AF116 ... AF370 3-pole contactors
with 2 N.O. + 2 N.C. auxiliary contacts
Main accessories
Main accessories
(other accessories available)
LW
Terminal
enlargement
CAL19-11B
2-pole auxiliary
contact block
5
CAL19-11B
2-pole auxiliary
contact block
AF contactor
with built-in cable clamps
TF/TA
Thermal overload relay
EF
Electronic overload relay
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL19-11
AF116 ... AF370
3 0
2 2
–
CAL19-11B
+
2 x CAL19-11B
Mechanical interlock units
(between two contactors)
–
Contactor types
AF116 ... AF140
AF146
AF190, AF205
AF265 ... AF370
Thermal overload relays
TF140DU (66...142 A)
–
TA200DU (66...200 A)
–
Electronic overload relays
EF146 (54...150 A)
EF146 (54...150 A)
EF205 (63...210 A)
EF370 (115...380 A)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
(1) Direct mounting - No kit required.
5/114 | ABB
1SFC101133C0201
Overload relays fitting details (1)
AF116 ... AF370 3-pole contactors
with 2 N.O. + 2 N.C. auxiliary contacts
Main accessories
Ordering details (1)
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
Side-mounted instantaneous auxiliary contact blocks
1
1 CAL19-11B
AF116 ... AF370
1SFC101041V0001
LT370-30C
Terminal shrouds
AF116 ... AF146, with compression lugs
AF190, AF205, with cable clamps
AF190, AF205, with compression lugs
AF190, AF205, with shorting bar or between contactor
and TOL/EOL in DOL-starters
AF265 ... AF370, with cable clamps
AF265 ... AF370, with compression lugs
AF265 ... AF370, with shorting bar or between contactor
and TOL/EOL in DOL-starters
AF265 ... AF370, for use with extending cable clamps,
ATK300/2 and OZXB4
1SFC101049V0001
For contactors
Dimensions
1SFN010820R3311
2
0.050
LT140-30L
LT205-30C
LT205-30L
LT205-30Y
1SFN124203R1000
1SFN124801R1000
1SFN124803R1000
1SFN124804R1000
2
2
2
1
0.070
0.050
0.220
0.050
LT370-30C
LT370-30L
LT370-30Y
1SFN125401R1000
1SFN125403R1000
1SFN125404R1000
2
2
1
0.035
0.280
0.075
LT370-30D
1SFN125406R1000
1
0.150
Type
Order code
Pkg
Weight
qty
(1 pce)
kg
hole Ø
mm
bar
mm
Terminal enlargements
AF116...AF146
AF190...AF205
AF265...AF370
6.5
10.5
10.5
13 x 3
17.5 x 5
20 x 5
LW140
LW205
LW370
1SFN074207R1000
1SFN074807R1000
1SFN075407R1000
1
1
1
0.115
0.260
0.340
Terminal extension
AF116...AF146
AF190...AF250
AF265...AF370
6.5
8.5
10.5
13 x 3
17.5 x 5
20 x 5
LX140
LX205
LX370
1SFN074210R1000
1SFN074810R1000
1SFN075410R1000
1
1
1
0.072
0.180
0.234
5
(1) For more information, refer to "Accessories" section.
1SFC101139C0201
1SFC101071V0001
kg
CAL19-11
LX140
Auxiliary
contacts
ABB | 5/115
AF400 ... AF750 3-pole contactors
200 to 400 kW
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
Description
1SFC101081V0001
AF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC or 600 V DC (2). These contactors are of the block type design with 3 main poles.
– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and
24...500 V DC
- can manage large control voltage variations
- reduced panel energy consumption
- very distinct closing and opening
- can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).
– built-in surge suppression
– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF460-30-22
Ordering details
1SFC101091V0001
5
AF750-30-22
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
690 V
AC-3
AC-1
kW
A
200
600
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
Uc
use
rating
600 V AC
hp
350
A
550
250
700
400
650
315
800
500
750
400
1050
600
900
V 50/60 Hz
48…130
100…250
250…500
48…130
100…250
250…500
48…130
100…250
250…500
48…130
100…250
250…500
Auxiliary Type
contacts
fitted
V DC
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AF400-30-22
AF400-30-22
AF400-30-22
AF400-30-22
AF460-30-22
AF460-30-22
AF460-30-22
AF460-30-22
AF580-30-22
AF580-30-22
AF580-30-22
AF580-30-22
AF750-30-22
AF750-30-22
AF750-30-22
AF750-30-22
Order code
Weight
Pkg
(1 pce)
kg
12.000
12.000
12.000
12.000
12.000
12.000
12.000
12.000
15.000
15.000
15.000
15.000
15.000
15.000
15.000
15.000
1SFL577001R6822 (1)
1SFL577001R6922
1SFL577001R7022
1SFL577001R7122
1SFL597001R6822 (1)
1SFL597001R6922
1SFL597001R7022
1SFL597001R7122
1SFL617001R6822 (1)
1SFL617001R6922
1SFL617001R7022
1SFL617001R7122
1SFL637001R6822 (1)
1SFL637001R6922
1SFL637001R7022
1SFL637001R7122
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative
pole.
(2) Up to 850 V DC for AF580, AF750.
AF400...AF750 are equipped with low voltage inputs for control, for example by a PLC.
ø12.5
0.49"
242 9.53"
6 0.24"
283 11.14"
48.5 1.91"
72 2.83"
AF580, AF750
E1633D
E1627D1
1SFC101123F0001
11.5 0.45"
6
0.24"
278 10.94"
1SFC101122F0001
63 2.48"
AF400, AF460
5/116 | ABB
48.5
1.91"
210 8.27"
ø6.5
22.5
0.89"
0.26"
40
1.57"
216 8.5"
ø10.5
0.41"
1SFC101014C0201 - Rev. A
mm, inches
268 10.55"
25
0.98"
186 7.32"
22.5
ø6.5
0.26"
0.89"
273 10.75"
Main dimensions
11.5 0.45"
Control inputs
AF1250 ... AF2650 3-pole contactors
475 to 560 kW and 1260 to 2650 A AC-1
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
Description
1SFC101092V0001
AF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC,
AF2650 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main
poles.
– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
- only 4 coils for AF1250 to cover control voltages between 48...500 V 50/60 Hz and 24...500 V DC
- only 1 coil for AF1350 ... AF2650 to cover control voltages between 100...250 V 50/60 Hz and
100...250 V DC
- can manage large control voltage variations
- reduced panel energy consumption
- very distinct closing and opening
- can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request).
– built-in surge suppression
– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF1250-30-22
UL/CSA
3-phase
motor
rating
480 V
475
560
-
800
900
-
1350
1650
2050
2650
hp
-
Rated control circuit
voltage
Uc
(1)
General
use
rating
600 V AC
(2)
A
V 50/60 Hz
1210
48…130
100…250
250…500
1350
100…250
1650
100…250
2100
100…250
2700
100...250
Auxiliary Type
contacts
fitted
V DC
24…60
48…130
100…250
250…500
100…250
100…250
100…250
100...250
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Order code
5
Weight
Pkg
(1 pce)
AF1250-30-22
AF1250-30-22
AF1250-30-22
AF1250-30-22
AF1350-30-22
AF1650-30-22
AF2050-30-22
AF2650-30-22
kg
16.000
16.000
16.000
16.000
34.000
35.000
35.000
45.000
1SFL647001R6822 (1)
1SFL647001R6922
1SFL647001R7022
1SFL647001R7122
1SFL657001R7022
1SFL677001R7022
1SFL707001R7022
1SFL667001R7022
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
(2) AF2650 : Maximum operational voltage = 1000 V according to UL / CSA.
AF1250 ... AF2650 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
AF1350, AF1650, AF2050
392 mm / 15.43"
47 mm / 1.85"
10 mm / 0.39"
A
B
C
Main dimensions
mm, inches
27
50 1.97"
ø 13
0.51"
13 0.51"
72 2.83"
30 1.18"
ø 7 0.28"
10 0.39"
ø 13
0.51"
13
0.51"
AF1350, AF1650
242 9.53"
40
1.57"
17 0.67"
17 0.67"
30 1.18"
40 1.57"
10 0.39"
AF2050
136 5.35"
AF2650
244 9.61"
136 5.35"
312 12.3"
80
3.15"
101
3.98"
136 5.35"
ø 9 0.35"
438 17.24"
AF1350, AF1650, AF2050, AF2650
ABB | 5/117
1SFC101095C0201 - Rev. A
8 0.31"
40
46.5
18.3"
1SFC101125F0001
A
72 2.83"
1SFC101124F0001
72 2.83"
210 8.27"
AF1250
C
249 9.8"
263 10.35"
B
ø7 0.28"
40
1.57"
17 0.67"
1.57"
27
AF2650
422 mm / 16.61"
53 mm / 2.11"
25 mm / 0.98"
40 1.57"
1.06"
313 12.32"
AF2650-30-22
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
690 V
AC-3
AC-1
kW
A
1260
344 13.54"
1SFC101032V0001
Ordering details
AF400... AF2650 3-pole contactors
with 2 N.O. + 2 N.C. auxiliary contacts
Main accessories
Main accessories
(other accessories available)
LW
Terminal
enlargement
LZ
Connector
terminal
CAL18-11B
2-pole auxiliary
contact block
5
VM
Mechanical
interlock
LT
Terminal shroud
AF contactor
CAL18-11B
2-pole auxiliary
contact block
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL18-11
Mechanical interlock units
CAL18-11B (2)
(between two contactors)
2 x CAL18-11B
–
Contactors + auxiliary contact blocks
AF145 ... AF2650
3 0
2 2
–
Contactors with mechanical interlocking + auxiliary contact blocks
AF400 ... AF2650
3 0
2 2
–
4 x CAL18-11B
+
VM...H (1)
Overload relays fitting details
Contactor types
AF400, AF460
AF580, AF750
AF1350, AF1650
Thermal overload relays
–
–
–
Electronic overload relays
EF460 (150...500 A) (3)
EF750 (250...800 A) (3)
E1250DU (375...1250 A) (3)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
(3) Mounting kit required (see "Motor protection").
5/118 | ABB
1SFC101127C0201 - Rev. A
(1) Interlock type, according to the contactor ratings (see "Accessories").
(2) The CEL18-.. auxiliary contact blocks can replace the CAL18-11 and CAL18-11B. Though, no auxiliary contact block can be mounted outside the CEL18-..
AF400 ... AF2650 3-pole contactors
with 2 N.O. + 2 N.C. auxiliary contacts
Main accessories
Ordering details (1)
1SFC101082V0001
For contactors
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
1SFC101089V0001
VM750H
Side-mounted instantaneous auxiliary contact blocks
1
1 CAL18-11B
AF400 ... AF2650
1SFN010720R3311
2
0.050
Mechanical interlock unit
AF400 ... AF1250
AF1350 ... AF2650
VM750H
VM1650H
1SFN035700R1000
1SFN036503R1000
1
1
0.200
6.000
Terminal shrouds
AF400, AF460 with connectors
AF400, AF460 with lugs
AF580 ... AF750 with connectors
AF580 ... AF750 with lugs
LT460-AC
LT460-AL
LT750-AC
LT750-AL
1SFN125701R1000
1SFN125703R1000
1SFN126101R1000
1SFN126103R1000
2
2
2
2
0.100
0.800
0.120
0.825
Type
Order code
Pkg
Weight
qty
(1 pce)
kg
For contactors
Dimensions
hole Ø
mm
bar
mm
Terminal enlargements
AF400, AF460
AF580, AF750
AF1250
10.5
13
13
25 x 5
40 x 6
50 x 10
LW460
LW750
LW1250
1SFN075707R1000
1SFN076107R1000
1SFN076407R1000
1
1
1
0.730
1.230
2.000
Terminal extension
AF400, AF460
AF580, AF750
10.5
13
25 x 5
40 x 6
LX460
LX750
1SFN075710R1000
1SFN076110R1000
1
1
0.500
0.850
LT460-AC
5
(1) For more information, refer to "Accessories" section.
1SFC101140C0201
1SFC101084V0001
CAL18-11
ABB | 5/119
AF09 ... AF38 3-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
AC / DC operated
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
θ ≤ 40 °C
Ie / Rated operational current AC-1
θ ≤ 60 °C
Ue max. ≤ 690 V, 50/60 Hz
M
3
3-phase motors
AF30
AF38
35 A
6 mm²
35 A
6 mm²
35 A
6 mm²
50 A
10 mm²
50 A
10 mm²
50 A
10 mm²
25 A
25 A
θ ≤ 70 °C 22 A
4 mm²
28 A
28 A
24 A
6 mm²
30 A
30 A
26 A
6 mm²
45
40
32
10
A
A
A
mm²
50
42
37
10
A
A
A
mm²
50
42
37
10
A
A
A
mm²
12 A
12 A
12 A
12 A
12.5 A
9A
18 A
18 A
18 A
18 A
15 A
10.5 A
26
26
26
26
23
17
A
A
A
A
A
A
33
32
32
32
28
21
A
A
A
A
A
A
40
38
38
38
33
24
A
A
A
A
A
A
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
9A
9A
9A
9A
9.5 A
7A
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
2.2 kW
3 kW
4 kW
4 kW
5.5 kW
7.5 kW
4 kW
5.5 kW
9 kW
4 kW
5.5 kW
9 kW
5.5 kW
7.5 kW
9 kW
5.5 kW
7.5 kW
9 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
6.5 kW
11 kW
11 kW
15 kW
15 kW
15 kW
9 kW
15 kW
15 kW
18.5 kW
18.5 kW
18.5 kW
11 kW
18.5 kW
18.5 kW
22 kW
22 kW
22 kW
12 A
5.5 kW
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a
Rated operational power AC-8a
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
1s
Rated short-time withstand current Icw
10 s
at 40 °C ambient temperature,
in free air from a cold state
30 s
25 A
300 A
150 A
80 A
1 min 60 A
15 min 35 A
Maximum breaking capacity
cos φ = 0.45
Power dissipation per pole
Max. electrical switching frequency
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-2, AC-4
250 A
106 A
0.8 W
0.1 W
600 cycles/h
1200 cycles/h
300 cycles/h
16 A
7.5 kW
22 A
11 kW
30 A
15 kW
40 A
20 kW
50 A
25 kW
32 A
300 A
150 A
80 A
60 A
35 A
32 A
300 A
150 A
80 A
60 A
35 A
50 A
700 A
350 A
225 A
150 A
50 A
63 A
700 A
350 A
225 A
150 A
50 A
63 A
700 A
350 A
225 A
150 A
50 A
250 A
106 A
1W
0.2 W
250 A
106 A
1.2 W
0.35 W
500 A
200 A
1.8 W
0.6 W
500 A
200 A
2.4 W
0.9 W
500 A
200 A
2.4 W
1.3 W
150 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101425S0201 - Rev. A
5
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
AF09
AF12
AF16
AF26
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
5/120 | ABB
AF40 ... AF96 3-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
AC / DC operated
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
θ ≤ 40 °C
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 60 °C
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
AF40
AF52
AF65
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
AF80
AF96
105 A
35 mm²
70
60
θ ≤ 70 °C 50
25
105 A
35 mm²
105 A
35 mm²
130 A
50 mm²
130 A
50 mm²
A
A
A
mm²
100 A
80 A
70 A
35 mm²
105 A
90 A
80 A
35 mm²
125 A
100 A
85 A
50 mm²
130 A
105 A
90 A
50 mm²
A
A
A
A
A
A
53
53
53
53
45
35
-
65
65
65
65
55
39
-
80
80
80
80
65
49
25
96 A
96 A
96 A
96 A
80 A
57 A
30A
5
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
40
40
40
40
35
25
-
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
11 kW
15 kW
18.5 kW
22 kW
22 kW
30 kW
22 kW
30 kW
22 kW
30 kW
22 kW
30 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
18.5 kW
30 kW
37 kW
37 kW
37 kW
37 kW
-
22 kW
37 kW
45 kW
45 kW
45 kW
45 kW
35 kW
25 kW
45 kW
55 kW
55 kW
55 kW
55 kW
40 kW
53 A
25 kW
70 A
37 kW
85 A
45 kW
105 A
55 kW
120 A
65 kW
125 A
1000 A
600 A
350 A
250 A
110 A
160 A
1000 A
600 A
350 A
250 A
110 A
160 A
1200 A
780 A
450 A
300 A
140 A
200 A
1200 A
780 A
450 A
300 A
140 A
950 A
600 A
6.3 W
1.7 W
950 A
600 A
7W
2.7 W
1150 A
750 A
7.6 W
3W
1150 A
750 A
8.2 W
4.5 W
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a
Rated operational power AC-8a
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
1 s
Rated short-time withstand current Icw
10 s
at 40 °C ambient temperature,
30 s
in free air from a cold state
100 A
1000 A
600 A
350 A
1 min 250 A
15 min 110 A
Maximum breaking capacity
cos φ = 0.45
Power dissipation per pole
Max. electrical switching frequency
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-2, AC-4
950 A
600 A
3W
1W
600 cycles/h
1200 cycles/h
150 cycles/h
1SBC101743S0201 - Rev. A
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
ABB | 5/121
AF116 ... AF370 3-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
AC / DC operated
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
θ ≤ 40 °C
Ie / Rated operational current AC-1
θ ≤ 60 °C
Ue max. ≤ 690 V, 50/60 Hz
Ie / Rated operational current AC-1
Ue max. ≤ 1000 V, 50/60 Hz
3-phase motors
AF305
AF370
1000 V
1000 V
1000 V
160 A
70 mm2
200 A
95 mm2
225 A
95 mm2
275 A
150 mm2
350 A
400 A
240 mm2 (3) 240 mm2
500 A
600 A
300 mm2 (4) 2 x 185 mm2 (4)
160 A
145 A
130 A
—
—
—
70 mm2
200 A
175 A
160 A
—
—
—
95 mm2
225 A
200 A
175 A
225 A
200 A
175 A
95 mm2
275
250
200
250
225
185
150
350
300
240
275
250
200
240
A
A
A
A
A
A
mm2 (3)
400
350
290
350
300
240
240
A
A
A
A
A
A
mm2
500
400
325
375
325
260
300
A
A
A
A
A
A
mm2 (4)
600 A
500 A
400 A
400 A
350 A
290 A
2 x 185 mm2 (4)
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
116 A
116 A
116 A
116 A
110 A
65 A
—
140 A
140 A
140 A
140 A
130 A
80 A
—
146 A
146 A
146 A
146 A
130 A
93 A
60 A
190 A
190 A
190 A
190 A
135 A
135 A
85 A
205
205
205
205
165
165
100
A
A
A
A
A
A
A
265
265
265
265
250
250
100
A
A
A
A
A
A
A
305
305
305
305
290
290
100
A
A
A
A
A
A
A
370
370
370
370
315
315
100
A
A
A
A
A
A
A
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
30 kW
37 kW
45 kW
55 kW
75 kW
75 kW
55 kW
75 kW
75 kW
75 kW
90 kW
90 kW
75 kW
90 kW
90 kW
55 kW
75 kW
90 kW
—
—
75 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
55 kW
90 kW
90 kW
110 kW
90 kW
132 kW
110 kW
55 kW
110 kW
110 kW
132 kW
110 kW
160 kW
132 kW
75 kW
132 kW
132 kW
160 kW
200 kW
200 kW
132 kW
90 kW
160 kW
160 kW
160 kW
200 kW
250 kW
132 kW
110
200
200
200
250
315
132
kW
kW
kW
kW
kW
kW
kW
315 A
1460 A
1168 A
674 A
477 A
225 A
355 A
1900 A
1520 A
878 A
621 A
275 A
400 A
2050 A
1640 A
947 A
670 A
350 A
500 A
2650 A
2120 A
1224 A
865 A
400 A
500 A
3050 A
2440 A
1409 A
996 A
500 A
630 A
3700 A
2960 A
1709 A
1208 A
600 A
3000 A
1500 A
23 W
10 W
3300 A
2200 A
15 W
7W
3500 A
2500 A
25 W
8W
3800 A
3300 A
32 W
14 W
4600 A
3800 A
50 W
19 W
5000 A
4000 A
72 W
27 W
θ ≤ 70 °C
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
AF265
A
A
A
A
A
A
mm2
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
250 A
315 A
1 s 1300 A
Rated short-time withstand current Icw
1460 A
10 s 928 A
at 40 °C ambient temperature,
1168 A
30 s 536 A
in free air from a cold state
674 A
1 min 379 A
477 A
15 min 160 A
200 A
Maximum breaking capacity
at 440 V 2000 A
3000 A
cos φ = 0.45
at 690 V 1000 A
1500 A
(cos φ = 0.35 for Ie > 100 A)
Ie / AC-1 12 W
Power dissipation per pole
18 W
Ie / AC-3 6 W
9W
AC-1 300 cycles/h
Maximum electrical switching frequency
AC-3 300 cycles/h
AC-2, AC-4 150 cycles/h
(1)
(2)
(3)
(4)
For
For
For
For
the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
currents above 275A use terminal enlargements or terminal extensions.
currents above 450A use terminal enlargements or terminal extensions.
1SFC101108C0201 - Rev. A
5
AF116
AF140
AF146
AF190
AF205
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
690 V
1000 V
1000 V
1000 V
50 / 60 Hz
5/122 | ABB
AF400 … AF2650 3-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
AC / DC operated
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area (3)
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1 θ ≤ 40 °C
θ ≤ 55 °C
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 70 °C
Ie / Rated operational current AC-1 θ ≤ 40 °C
θ ≤ 55 °C
Ue max. ≤ 1000 V, 50/60 Hz
θ ≤ 70 °C
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
AF400
AF460
AF580
AF750
AF1250
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
1000 V
50/60 Hz
AF1350
600 A
700 A
800 A
1050 A
2x185 mm² 2x240 mm² 2x240 mm² 800 mm² (4)
1260 A
1000 mm² (4)
1350 A
1650 A
2050 A
2650 A
1000 mm² (5) 1500 mm² (5) 2000 mm² (5) 3000 mm² (5)
600 A
500 A
400 A
600 A
500 A
400 A
2x185 mm²
700 A
600 A
480 A
700 A
600 A
480 A
2x240 mm²
800 A
700 A
580 A
800 A
700 A
580 A
2x240 mm²
1050 A
875 A
720 A
1000 A
875 A
720 A
800 mm² (4)
1260 A
1040 A
875 A
1260 A
1040 A
875 A
1000 mm² (4)
1350 A
1150 A
1000 A
1350 A
1150 A
1000 A
1000 mm² (5)
1650 A
1450 A
1270 A
1650 A
1450 A
1270 A
1500 mm² (5)
2050 A
1750 A
1500 A
2050 A
1750 A
1500 A
2000 mm² (5)
2650 A
2350 A
2120 A
2650 A
2350 A
2120 A
3000 mm² (5)
400
400
400
400
400
350
155
460
460
460
460
460
400
200
580
580
580
580
580
500
250
750
750
750
750
750
650
300
A
A
A
A
A
A
A
–
–
–
–
–
–
–
860
860
860
860
800
800
–
A
A
A
A
A
A
1060 A
1060 A
1060 A
1060 A
970 A
970 A
–
1060 A
1060 A
1060 A
1060 A
970 A
970 A
–
–
–
–
–
–
–
–
kW
kW
kW
kW
kW
kW
kW
–
–
–
–
–
–
–
257
475
500
560
560
800
–
kW
kW
kW
kW
kW
kW
315 kW
560 kW
630 kW
710 kW
700 kW
1000 kW
–
–
–
630 kW
710 kW
–
1000 kW
–
–
–
–
–
–
–
–
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AF1650
AF2050
AF2650
5
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection device for contactors
without thermal overload relay
Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
1s
Rated short-time withstand current Icw
10 s
at 40 °C ambient temperature,
in free air from a cold state
30 s
110 kW
132 kW
160 kW
220
200 kW
250 kW
315 kW
400
220 kW
250 kW
355 kW
425
220 kW
250 kW
355 kW
450
250 kW
315 kW
400 kW
520
315 kW
355 kW
500 kW
600
220 kW
280 kW
355 kW
400
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
630 A
4600 A
4400 A
3100 A
1 min 2500 A
15 min 840 A
Maximum breaking capacity
cos φ = 0.45
(cos φ = 0.35 for Ie > 100 A)
Power dissipation per pole
Max. electrical switching
frequency
4000 A
5000 A
3500 A
4500 A
30 W
42 W
16 W
21 W
300 cycles/h
300 cycles/h
60 cycles/h
1000
7000
6400
4500
3500
1300
A
A
A
A
A
A
1000
7000
6400
4500
3500
1300
A
A
A
A
A
A
6000 A
7500 A
5000 A
7000 A
32 W
50 W
17 W
28 W
300 cycles/h
300 cycles/h
60 cycles/h
Please consult us for coordination with circuit-breaker
8000 A
10000 A
12000 A
12000 A
12000 A
7200 A
8000 A
10000 A
10000 A
10000 A
5200 A
6000 A
7500 A
7500 A
7500 A
4000 A
4500 A
5500 A
5500 A
5500 A
1500 A
1600 A
2200 A
2200 A
2800 A
10000 A
–
80 W
80 W
–
50 W
300 cycles/h 60 cycles/h
–
60 cycles/h
–
60 cycles/h
12000 A
–
80 W
50 W
8400 A
–
125 W
–
60 cycles/h
–
–
8400 A
–
200 W
–
15 cycles/h
–
–
For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
Conductors with preparation.
Max. connection bar width 50 mm.
Max. connection bar width 100 mm.
1SFC101110C0201 - Rev. C
(1)
(2)
(3)
(4)
(5)
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-2, AC-4
800 A
4600 A
4400 A
3100 A
2500 A
840 A
ABB | 5/123
AF09 ... AF38 3-pole contactors
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
Standards
Max. operational voltage
NEMA size
NEMA continuous amp rating
NEMA maximum horse power ratings
1-phase, 60 Hz
NEMA maximum horse power ratings
3-phase, 60 Hz
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
AF26
AF30
AF38
1
27 A
–
–
115 V AC
230 V AC
1/3 hp
1 hp
1 hp
2 hp
2 hp
3 hp
200 V AC
230 V AC
460 V AC
575 V AC
1-1/2 hp
1-1/2 hp
2 hp
2 hp
3
3
5
5
7-1/2 hp
7-1/2 hp
10 hp
10 hp
25 A
AWG 10
28 A
AWG 10
30 A
AWG 10
45 A
AWG 8
50 A
AWG 8
50 A
AWG 8
120 V AC
240 V AC
120 V AC
240 V AC
13.8 A
10 A
3/4 hp
1-1/2 hp
16 A
12 A
1 hp
2 hp
20 A
17 A
1-1/2 hp
3 hp
24 A
17 A
2 hp
3 hp
24 A
28 A
2 hp
5 hp
24 A
28 A
2 hp
5 hp
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
7.8 A
6.8 A
7.6 A
9A
2 hp
2 hp
5 hp
7-1/2 hp
11 A
9.6 A
11 A
11 A
3 hp
3 hp
7-1/2 hp
10 hp
17.5 A
15.2 A
14 A
17 A
5 hp
5 hp
10 hp
15 hp
25.3 A
22 A
21 A
22 A
7-1/2 hp
7-1/2 hp
15 hp
20 hp
32.2 A
28 A
27 A
27 A (2)
10 hp
10 hp
20 hp
25 hp (2)
32.2 A
28 A
34 A (3)
32 A (3)
10 hp
10 hp
25 hp (3)
30 hp (3)
100 kA
30 A
J
30 A
60 A
60 A
100 A
100 A
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
High fault current
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
For general use
For motor use
hp
hp
hp
hp
600 cycles/h
1200 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.
(2) For contactors produced since week 49-2011.
(3) For contactors produced since week 36-2014.
General technical data
AC / DC operated
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
B2
C2
Vibration withstand
acc. to IEC 60068-2-6
5/124 | ABB
Shock direction
A
B1
B2
C1
C2
AF09
AF12
AF16
AF26
AF30
AF38
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A
-25...+60 °C
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
10 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
30 g
25 g closed position / 5 g open position
15 g
25 g
25 g
5...300 Hz
4 g closed position / 2 g open position
1SBC101426S0201 - Rev. B
5
UL / CSA general use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
AF09
AF12
AF16
UL 508, CSA C22.2 N°60947-4-1
600 V
00
0
–
Thermal current 9 A
18 A
AC / DC operated
AF40 ... AF96 3-pole contactors
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
Standards
Maximum operational voltage
NEMA size
NEMA continuous amp rating
NEMA maximum horse power ratings
1-phase, 60 Hz
NEMA maximum horse power ratings
3-phase, 60 Hz
UL / CSA general use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
AF40
AF52
AF65
UL 60947-4-1, CSA C22.2 N°60947-4-1
600 V
2
Thermal current 45 A
-
AC / DC operated
AF80
AF96
3
90 A
-
115 V AC
230 V AC
3 hp
7.5 hp
-
-
-
200 V AC
230 V AC
460 V AC
575 V AC
10
15
25
25
-
-
25
30
50
50
60 A
AWG 6
80 A
AWG 4
90 A
AWG 3
105 A
AWG 2
115 A
AWG 2
34 A
40 A
3 hp
7-1/2 hp
34 A
50 A
3 hp
10 hp
56 A
68 A
5 hp
15 hp
80 A
68 A
7-1/2 hp
15 hp
80 A
88 A
7-1/2 hp
20 hp
32.2 A
42 A
40 A
41 A
10 hp
15 hp
30 hp
40 hp
48.3 A
54 A
52 A
52 A
15 hp
20 hp
40 hp
50 hp
62.1 A
68 A
65 A
62 A
20 hp
25 hp
50 hp
60 hp
78.2 A
80 A
77 A
77 A
25 hp
30 hp
60 hp
75 hp
92
80
77
77
30
30
60
75
100 kA
150 A
J
150 A
150 A
200 A
200 A
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
High fault current
Fuse rating
Fuse type, 600 V
Maximum electrical switching frequency
For general use
For motor use
hp
hp
hp
hp
hp
hp
hp
hp
-
5
A
A
A
A
hp
hp
hp
hp
600 cycles/h
1200 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
C1
A
A
B1
B2
C2
Vibration withstand
acc. to IEC 60068-2-6
Shock direction
A
B1
B2
C1
C2
AF40
AF52
AF65
AF80
AF96
690 V
1000 V
600 V
6 kV
8 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A and B
-25...+60 °C
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
10 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
25 g
25 g closed position / 5 g open position
15 g
25 g
25 g
5...300 Hz
3 g closed position / 3 g open position
1SBC101744S0201 - Rev. A
AC / DC operated
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Maximum switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
ABB | 5/125
AF116 ... AF370 3-pole contactors
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
Standards
Maximum operational voltage
NEMA size
NEMA continuous amp rating
NEMA maximum horse power ratings
1-phase, 60 Hz
NEMA maximum horse power ratings
3-phase, 60 Hz
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
AF190
AF205
60947-1 / 60947-4-1A
AF265
AF305
AF370
—
—
—
—
5
270 A
—
—
—
—
115 V AC
230 V AC
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
200 V AC
230 V AC
460 V AC
575 V AC
—
—
—
—
40 hp
50hp
100 hp
100 hp
—
—
—
—
—
—
—
—
—
—
—
—
75 hp
100 hp
200 hp
200 hp
—
—
—
—
—
—
—
—
160 A
AWG 2/0
200 A
AWG 3/0
200 A
AWG 3/0
250 A
MCM 250
300 A
350 A
MCM 350 (2) MCM 500
400 A
2//AWG 3/0
520 A
2//MCM 300
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
92 A
104 A
96 A
99 A
30 hp
40 hp
75 hp
100 hp
120 A
130 A
124 A
125 A
40 hp
50 hp
100 hp
125 hp
120 A
130 A
124 A
125 A
40 hp
50 hp
100 hp
125 hp
150 A
154 A
156 A
144 A
50 hp
60 hp
125 hp
150 hp
177 A
192 A
180 A
192 A
60 hp
75 hp
150 hp
200 hp
221 A
248 A
240 A
242 A
75 hp
100 hp
200 hp
250 hp
285
312
302
289
100
125
250
300
100 kA
225 A
J
250 A
250 A
450 A
400 A
500 A
600 A
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
High fault current
Fuse rating
Fuse type, 600 V
Maximum electrical switching frequency
For general use
For motor use
A
A
A
A
hp
hp
hp
hp
359
360
361
336
125
150
300
350
A
A
A
A
hp
hp
hp
hp
800 A
300 cycles/h
300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For conductor cross-sectional area above MCM 300 use terminal enlargements LW205.
General technical data
AC / DC operated
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Maximum switching frequency
AF116
AF140
AF146
AF190
AF205
AF265
AF305
AF370
1000 V
600 V
8 kV
AF contactors comply with IEC 60947-1 / EN 60947-1 - Environment A
-25 to +55 °C
-40 to +70 °C
-40 to +70 °C
3000 m
5 million operating cycles
300 cycles/h
1SFC101109C0201
5
UL / CSA general use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
AF116
AF140
AF146
UL 60947-1 / 60947-4-1A and CSA
600V
—
4
—
Thermal current —
135 A
—
AC / DC operated
5/126 | ABB
AF400 ... AF2650 3-pole contactors
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
Standards
Maximum operational voltage
NEMA size
NEMA maximum horse power ratings
1-phase, 60 Hz
AC / DC operated
NEMA maximum horse power ratings
3-phase, 60 Hz
UL / CSA general use rating
1000 V AC
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
AF400
AF460
AF580
UL 508, CSA C22.2 N°14
600 V
–
6
–
AF750
AF1250
AF1350
AF1650
AF2050
AF2650
7
1000 V
–
8
–
–
–
–
–
–
–
300 hp
600 hp
600 hp
–
–
–
–
–
450 hp
900 hp
900 hp
–
–
–
–
–
–
–
–
115 V AC
230 V AC
–
–
200 V AC
230 V AC
460 V AC
575 V AC
–
–
–
–
150
200
400
400
550 A
650 A
750 A
900 A
1210 A
1350 A
1650 A
2100 A
2700 A
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
358.8 A
360 A
414 A
382 A
125 hp
150 hp
350 hp
400 hp
414
480
477
472
150
200
400
500
692.3 A
722 A
722 A
672 A
250 hp
300 hp
600 hp
700 hp
–
–
–
–
–
–
–
–
954 A
954 A
954 A
944 A
–
400 A
800 A
1000 A
1030 A
1030 A
1030 A
1050 A
–
450 hp
900 hp
1150 hp
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Maximum electrical switching frequency
For general use
For motor use
hp
hp
hp
hp
A
A
A
A
hp
hp
hp
hp
1000 A
L
552
604
590
578
200
250
500
600
A
A
A
A
hp
hp
hp
hp
1200 A
5
Please consult us for coordination with
circuit-breaker
300 cycles/h
300 cycles/h
60 cycles/h
60 cycles/h
15 cycles/h
–
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.
General technical data
AC / DC operated
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
Fitted with electronic overload relay
Without electronic overload relay
Storage
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
AF400
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
300 cycles/h
A
ABB
A
B1
B2
C2
Shock direction
A
B1
B2
C1
C2
AF580
AF750
AF1250
AF1350
AF1650
AF2050
AF2650
1000 V
600 V
1000 V
8 kV
AF contactors complying with IEC 60947-1 / EN 60947-1 - Environment A
-25 to +70 °C
-40 to +70 °C
-40 to +70 °C
3000 m
3 millions operating cycles
0.5 million operating cycles
0.3 million
operating
cycles
60 cycles/h
1/2 sinusoidal shock for 30 ms: no change in contact position, closed or open position
5g
–
5g
–
5g
–
5g
–
5g
–
1SFC101111C0201 - Rev. B1
C1
AF460
ABB | 5/127
AF09 ... AF38 3-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC / DC operated
AC supply
DC supply
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Coil consumption
PLC-output control
Drop-out voltage
Voltage sag immunity
acc. to SEMI F47-0706
Dips withstand
-20 °C ≤ θ ≤ +60 °C
Operating time
Between coil energization and:
Between coil de-energization and:
Average pull-in value
Average holding value
AF26
AF30
AF38
At θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C (AF) 0.85 x Uc min...Uc max. - (AF..Z) 0.85 x Uc min...1.1 x Uc max.
24...500 V AC
(AF) 50 VA - (AF..Z) 16 VA
(AF) 2.2 VA / 2 W - (AF..Z) 1.7 VA / 1.5 W
12...500 V DC
(AF) 50 W - (AF..Z) 12...16 W
(AF) 2 W - (AF..Z) 1.7 W
(AF..Z) ≥ 500 mA 24 V DC
≤ 60 % of Uc min.
(AF..Z) conditions of use on request
(AF..Z) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DC
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
40...95
38...90
11...95
13...98
ms
ms
ms
ms
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
AF09
AF12
Pos. 2
+30°
AF16
AF26
AF30
AF38
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Max. N.C. built-in and add-on N.C. auxiliary contacts:
see accessory fitting details for a 3-pole contactor AF09 ... AF38
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
The contactors can be assembled side by side
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101427S0201 - Rev. A
5
Average pull-in value
Average holding value
AF09
AF12
AF16
At θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C 0.85 x Uc min...Uc max.
5/128 | ABB
AF40 ... AF96 3-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Coil consumption
PLC-output control
Drop-out voltage
Voltage sag immunity
acc. to SEMI F47-0706
Dips withstand
-20 °C ≤ θ ≤ +60°C
Operating time
Between coil energization and:
Between coil de-energization and:
AC / DC operated
AC supply
DC supply
AF40
AF52
AF65
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.
AF80
AF96
24...500 V AC
Average pull-in value 25 VA
Average holding value 4 VA / 2 W
Average pull-in value
Average holding value
40 VA
20...500 V DC
25 W
2W
≤ 60 % of Uc min.
40 W
conditions of use on request
5
24 ms average
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
42...100 ms
38...95 ms
17...100 ms
19...105 ms
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
AF40
AF52
Pos. 2
+30°
AF65
AF80
AF96
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Max. N.C. built-in and add-on N.C. auxiliary contacts:
see accessory fitting details for a 3-pole contactor AF40 ... AF96
The contactors can be assembled side by side
35 x 7.5 mm or 35 x 15 mm
2 x M4 or 2 x M6 screws placed diagonally
35 x 15 mm
1SBC101745S0201
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
ABB | 5/129
AF116 ... AF370 3-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
Rated control circuit voltage Uc
Coil consumption
AC control voltage 50/60 Hz
24...60 V AC
48...130 V AC
100...250 V AC
250...500 V AC
DC control voltage
20...60 V DC
48...130 V DC
100...250 V DC
250...500 V DC
Drop-out voltage
Operating time
Coil supply between A1 - A2
Between coil energization and:
Between coil de-energization and:
AF116
AF140
AF146
AF190
At θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max
At θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc max
24...500 V AC, 20...500 V DC
AF205
AF265
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
225 VA
5.5 VA
170 VA
4 VA
130 VA
6 VA
205 VA
16 VA
165 VA
6 VA
175 VA
4 VA
220 VA
7 VA
185 VA
16 VA
475 VA
8.5 VA
340 VA
17 VA
385 VA
17.5 VA
420 VA
21 VA
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
210 W
2.5 W
130 W
2.5 W
135 W
3W
205 W
4W
55 % of Uc min
205 W
2.5 W
130 W
2.5 W
190 W
2.5 W
190 W
4W
400 W
3.5 W
360 W
2.5 W
410 W
4.5 W
600 W
4.7 W
20...55 ms
40..70 ms
25...60 ms
45...80 ms
30...60 ms
45...80 ms
N.O. contact closing
N.O. contact opening
AF305
AF370
AF305
AF370
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
AF116
AF140
Pos. 2
AF146
+30°
AF190
AF205
AF265
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Pos. 6
Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor
AF116 ... AF370
Mounting distances
Fixing
On rail acc. to IEC 60715, EN 60715
By screws (not supplied)
The contactors can be assembled side by side
–
4 x M5
1SFC101112C0201 - Rev. A
5
AC / DC operated
AC supply
DC supply
5/130 | ABB
AF400 ... AF2650 3-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
Rated control circuit voltage Uc
Coil consumption
AC control voltage 50/60 Hz
24...60 V AC
48...130 V AC
100...250 V AC
250 … 500 V AC
DC control voltage
20...60 V DC
48...130 V DC
100...250 V DC
250 … 500 V DC
Drop-out voltage
Voltage sag immunity
acc. to SEMI F47
Dips withstand
Operating time
Coil supply between A1 - A2
Between coil energization and:
Between coil de-energization and:
Control input for PLC's
Between coil energization and:
Between coil de-energization and:
AC / DC operated
AC supply
DC supply
AF400
AF460
AF580
AF750
At θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max
At θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc max
24...500 V AC, 20...500 V DC
AF1250
AF1350
AF1650
AF2050
AF2650
100...250 V AC or DC
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
900 VA
12 VA
1215 VA
12 VA
955 VA
12 VA
950 VA
12 VA
780 VA
12 VA
1100 VA
12 VA
880 VA
12 VA
985 VA
12 VA
2450 VA
48 VA
-
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
900 VA
785 VA
5 VA
5.5 VA
1150 VA
1020 VA
5 VA
5 VA
895 VA
880 VA
5 VA
5 VA
885 VA
910 VA
7.5 VA
7.5 VA
55 % of Uc min.
Conditions of use on request
2290 VA
20.5 VA
-
5
≥ 20 ms
Main contact closing
Main contact opening
50…120 ms
33…70 ms
Main contact closing
Main contact opening
40…60 ms
10…30 ms
50…80 ms
35…55 ms
40...90 ms
40…65 ms
10…30 ms
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
AF400
AF460
Pos. 2
AF580
+30°
AF750
AF1250
AF1350
AF1650
AF2050
AF2650
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 5
Pos. 6
–
4 x M5
4 x M6
4 x M8
1SFC101113C0201 - Rev. A
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor
AF400 ... AF2650
The contactors can be assembled side by side
ABB | 5/131
AF09 ... AF38 3-pole contactors
Technical data
Connecting characteristics
Contactor types
Main terminals
AC / DC operated
AF09
AF12
AF16
AF26
AF30
AF38
Screw terminals with cable clamp
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
1...6 mm²
1...6 mm²
0.75...6 mm²
0.75...6 mm²
0.75...4 mm²
0.75...2.5 mm²
9.6 mm
2.5...10 mm²
2.5...10 mm²
1.5...10 mm²
1.5...10 mm²
1.5...10 mm²
1.5...4 mm²
12.5 mm
AWG 16...10
10 mm
1.5 Nm / 13 lb.in
AWG 14...8
14 mm
2.5 Nm / 22 lb.in
6
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
1 or 2 x
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
Lugs
1x
2x
1x
2x
1x
2x
L<
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
6
1 or 2 x
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Coil terminals
Built-in auxiliary terminals
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Built-in auxiliary terminals
Screw terminals
Main terminals
Coil terminals
Built-in auxiliary terminals
AWG 18...14
10 mm
1.2 Nm / 11 lb.in
1.2 Nm / 11 lb.in
IP20
IP20
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
M4
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Flat Ø 6.5 / Pozidriv 2
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101428S0201 - Rev. A
5
Bars or lugs
1x
2x
1x
2x
1x
2x
L<
5/132 | ABB
AF40 ... AF96 3-pole contactors
Technical data
Connecting characteristics
Contactor types
Main terminals
AC / DC operated
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
Bars or lugs
AF40
AF52
AF65
AF80
AF96
Screw terminals with double connector
2 x (9.3 width x 7.9/10.3 depth)
Screw terminals with double connector
2 x (12.4 width x 9.3/11.1 depth)
6...35 mm²
6...35 mm²
4...35 mm²
4...35 mm²
4...35 mm²
4...35 mm²
9.2 mm
6...70 mm²
6...50 mm²
6...50 mm²
6...50 mm²
6...50 mm²
6...50 mm²
12.2 mm
1 or 2 x
AWG 10...2
16 mm
4 Nm / 35 lb.in
AWG 6...1
17 mm
6 Nm / 53 lb.in
1x
2x
1x
2x
1x
2x
L<
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
1x
2x
1x
2x
1x
2x
L<
5
6
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
Lugs
6
1 or 2 x
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Coil terminals
Built-in auxiliary terminals
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Built-in auxiliary terminals
Screw terminals
Main terminals
Built-in auxiliary terminals
1.2 Nm / 11 lb.in
1.2 Nm / 11 lb.in
IP10
IP20
IP20
Delivered in open position, screws of unused terminals must be tightened
M6
M8
Screwdriver type Flat Ø 6.5 / Pozidriv 2
Hexagon socket (s = 4 mm)
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101746S0201
Coil terminals
AWG 18...14
10 mm
ABB | 5/133
AF116 ... AF370 3-pole contactors
Technical data
Connecting characteristics
AC / DC operated
AF116
AF140
AF146
AF190
8 Nm
–
–
–
1 x 10...70 mm²
LD... included (1)
8 Nm
2 x 10...70 mm²
LD... included (1)
1x
8 Nm
22 mm (.866 in)
6 mm (.236 in)
LL... included
9 Nm / 80 lb.in
1 x AWG 6…3/0
LD... included (1)
8 Nm / 71 lb.in
2 x AWG 6…3/0
LD... included (1)
8 Nm / 71 lb.in
Lugs
W≤
Ø>
Socket type
Tightening torque
Connection capacity acc. to UL / CSA
Clamp type
Tightening torque
Connection capacity acc. to UL / CSA
Clamp type
Tightening torque
Auxiliary conductors
(coil terminals)
Solid / stranded
Flexible
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
1x
2x
1x
2x
1x
2x
1x
2x
L<
l>
1 or 2 x
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Screw terminals
Main terminals
AF370
5
10
7
10...95 mm²
LD... included (1)
8 Nm
2 x 10...95 mm²
LD... included (1)
1x
Tightening torque
ø L
AF305
19.5
5
ø 6.5
Tightening torque
Al cable - Stranded
Clamp type
Tightening torque
Cu cable - Flexible
Clamp type
Tightening torque
Cu cable - Flexible
Clamp type
AF265
17.5
3
Connection capacity (min. ... max.)
Main conductors (poles)
Cu cable - Stranded
Clamp type
Tightening torque
Cu cable - Stranded
Clamp type
5
AF205
13
ø 8.5
ø 10.5
6...150 mm²
1SDA066917R1
14 Nm
50...120 mm²
1SFN074709R1000,
LZ185-2C/120
16 Nm
95...185 mm²
1SDA054988R1
31 Nm
6...120 mm²
1SDA066917R1
14 Nm
50...95 mm²
1SFN074709R1000,
LZ185-2C/120
16 Nm
24 mm (.945 in)
8 mm (.315 in)
LL... included
18 Nm / 160 lb.in
6…300 MCM
ATK185 (2)
34 Nm / 301 lb.in
–
–
–
16...300 mm²
1SDA055016R1
25 Nm
70...185 mm²
1SCA022194R0890,
OZXB4
22 Nm
185...240 mm²
1SDA055020R1
43 Nm
16...240 mm²
1SDA055016R1
25 Nm
70...185 mm²
1SCA022194R0890,
OZXB4
22 Nm
32 mm (1.260 in)
10 mm (.394 in)
LL... included
28 Nm / 248 lb.in
4…400 MCM
ATK300 (2)
42 Nm / 372 lb.in
4…500 MCM
ATK300/2 (2)
42 Nm / 372 lb.in
M8
M10
14.3
Contactor types
Main terminals
Flat type
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.5 mm
AWG 18...14
9 mm
1.00 Nm / 9 lb.in
IP00
IP20
M6
Screws and bolts
Coil terminals (delivered in open position)
M3.5
Screwdriver type Flat Ø 5.5 mm / Pozidriv 2
Screwdriver type
1SFC101114C0201
(1) LD... not included for AF116 ... AF146-30-..B.
(2) Available in North America only.
5/134 | ABB
AF400 ... AF2650 3-pole contactors
Technical data
Connecting characteristics
Contactor types
Main terminals
Flat type
AC / DC operated
AF400
AF460
AF580
AF750
AF1250
AF1350
AF1650
AF2050
AF2650
80
10 (AF2050)
25 (AF2650)
ø 12.5
AF580
AF750
40
AF2050
AF2650
17
ø 13
ø 6.5
40
27
10
30
ø 10.5 ø 6.5
6
80
AF1250
10
22.5
8
15.5
6
40
22.5
25
25
17
40
50
27
ø 13
AF1350
AF1650
Connection capacity (min. ... max.)
Main conductors (poles)
Cu cable - Stranded
Clamp type
Tightening torque
Cu cable - Stranded
Clamp type
Tightening torque
Al cable - Stranded
Clamp type
Tightening torque
2x
3x
2x
3x
ø L
Lugs
Clamp type
Tightening torque
W≤
Ø>
Tightening torque
Connection capacity acc. to UL / CSA
2x
Clamp type
Tightening torque
Connection capacity acc. to UL / CSA
Clamp type
3x
Tightening torque
Auxiliary conductors
(coil terminals)
Solid / stranded
Flexible
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
1x
2x
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
Connection capacity acc. to UL / CSA
Tightening torque
Recommended
Max.
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Screw terminals
Main terminals
240 mm²
–
1SDA013922R1
–
35 Nm
–
–
185 mm²
–
1SDA013956R1
35 Nm
45 Nm
240 mm²
–
1SDA013922R1
–
35 Nm
–
–
185 mm²
–
1SDA013956R1
35 Nm
45 Nm
47 mm
50 mm
10 mm
12 mm
35 Nm / 310 Ib.in
45 Nm / 398 lb.in
250-500 MCM alt. 2/0 –
AWG-400 MCM
K6TH alt. ATK580
–
275 Ib.in
2/0 AWG-400 MCM
K6TJ
–
2/0 AWG-500 MCM
ATK750/3
275 Ib.in
375 Ib.in
5
–
–
–
–
–
–
2// 3 x
0.25 in
bars, use
LW1250
100 mm
4/0 AWG - 500 MCM
4//4 x 0.25 in
K7TK
K7TK
ATK1350/4
375 Ib.in
1/0-750 MCM
K8TL,
K8TL,
K8TM,
K8TM,
ATK1650/4 ATK1650/4,
ATK1650/6
500 Ib.in
bars
–
–
–
–
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.7 mm
AWG 18...14
1.00 Nm / 9 lb.in
1.20 Nm
IP00
IP20
1SFC101115C0201
M10
M12
Screws and bolts
Coil terminals (delivered in open position)
M3.5
Screwdriver type Flat Ø 5.5 mm / Pozidriv 2
ABB | 5/135
AF09 ... AF96 3-pole contactors
Technical data
Built-in auxiliary contacts according to IEC
Contactor types
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free air thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
for 1.0 s
for 0.1 s
AC-15
DC-13
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
Mirror contacts
acc. to annex F of IEC 60947-4-1
AF09
AF12
690 V
50 / 60 Hz
16 A
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
≥ 2 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4, CAL4, CAT4
aux. contact blocks) are mechanically linked contacts.
Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA4, CAL4, CAT4 aux. contact blocks)
are mirror contacts.
Built-in auxiliary contacts according to UL / CSA
Contactor types
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
AC / DC operated
AF09
AF12
AF16
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
1SBC101445S0201 - Rev. A
5
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
AC / DC operated
5/136 | ABB
3-pole contactors
Electrical durability and utilization categories
General
Utilization categories determine the current making and breaking conditions relating to the characteristics of the loads to be
controlled by the contactors. International standard IEC 60947-4-1 and European standard EN 60947-4-1 are the standards to
be referred to.
If Ic is the current to be broken by the contactor and Ie the rated operational current normally drawn by the load, then:
– – Categories AC-1 and AC-3: Ic = Ie
–– Category AC-2: Ic = 2.5 x Ie
–– Category AC-4: Ic = 6 x Ie
Generally speaking Ic = m x Ie where m is a multiple of the load operational current.
On next pages, the curves corresponding to categories AC-1, AC-3 and AC-4 represent the electrical durability variation of
standard contactors in relation to the breaking current Ic.
Electrical durability is expressed in millions of operating cycles.
5
Curve utilization mode
Electrical durability forecast and contactor selection for categories AC-1, AC-2, AC-3 or AC-4
• Note the characteristics of the load to be controlled:
–– Operational voltage ........................................... Ue
– – Current normally drawn . .................................... Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents").
– – Utilization category ........................................... AC-1, AC-2, AC-3 or AC-4
– – Breaking current ............................................... Ic = Ie for AC-1 and for AC-3 ; Ic = 2.5 x Ie for AC-2 ; Ic = 6 x Ie for AC-4
• Define the number of operating cycles N required.
• On the diagram corresponding to the operational category, select the contactor with the curve immediately above the intersection point (Ic ; N).
Electrical durability forecast and contactor selection for mixed duty motor control: AC-3 (Ic = Ie) type switching off while
"motor running" and, occasionally, AC-4 (Ic = 6 x Ie) type switching off while "motor accelerating"
• Note the characteristics of the motor to be controlled:
–– Operational voltage ....................................................... Ue
– – Current normally drawn while "motor running" . ............... Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents")
– – Breaking current for AC-3 ............................................. Ic = Ie
– – Breaking current for AC-4 while "motor accelerating"...... Ic = 6 x Ie
– – Percentage of AC-4 operating cycles ............................. K (on the basis of the total number of operating cycles)
• Define the total number of operating cycles N required.
• Note the smallest contactor rating compatible for AC-3 (Ue / Ie) on Main pole utilization characteristic table (see “Technical data”).
• For the selected contactor make a note of the following in relation to the voltage using diagram AC-3 in next pages:
–– The number of operating cycles A for Ic = Ie (AC-3)
–– The number of operating cycles B for Ic = 6 x Ie (AC-4)
• Calculate the estimated number of cycles N’ (N’ is always below A)
A
N'=
1 + 0.01 K (A/B - 1)
• If N' is too low in relation to the target N, calculate the estimated number of cycles for a higher contactor rating.
1SBC101314S0201
Case of uninterrupted duty
For uninterrupted duty, some verifications of preventing maintenance are necessary to check the functionality of the concerned
product (consult us).
The combined effect of environmental conditions and the proper temperature of the product may require some disposals. As a
matter of fact, for this duty, the use duration prevails over the number of operating cycles.
ABB | 5/137
3-pole contactors
Electrical durability
Electrical durability for AC-1 utilization category - Ue ≤ 690 V
Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of
the load.
Ambient temperature and maximum electrical switching frequency: see "Technical data".
AF1250, AF1350,
AF1650, AF2050:
The electrical durability at
the rated current is 50000
operating cycles.
AF
AF
40
AF 0
46
0
20
AF 5
2
AF 65
30
AF 5
37
0
AF
AF 6
19
0
0
14
AF
6
11
14
AF
AF
,A
80
65
AF
52
AF
AF
58
AF 0
75
0
6
F9
8
40
F3
AF
AF
26
AF
30
,A
12
AF
16
09
AF
AF
Millions of
operating
cycles
10
5
3
9
7
5
3
1
2
9
7
5
3
1
1
0.5
0.3
9
7
5
3
1
0.2
1 3 5 7 9
0.1
1
2
3
5
10
3
5
7
9
20
1 3 5 7 9
1 59
1
30
26.5
50
100
3
5
7
9
200
1 3 579
300
1 5 9
500
1000
Breaking current Ic (A)
Example:
Ic / AC-1 = 26.5 A – Electrical durability required = 2 millions operating cycles.
Using the AC-1 curves above select the AF26 contactor at intersection " " (26.5 A / 2 millions operating cycles).
1SBC101940S0201
5
5/138 | ABB
3-pole contactors
Electrical durability
AF1350, AF1650:
The electrical durability at
the rated current is 50000
operating cycles.
AF
75
0
AF
14
AF 0,
19 AF
14
AF 0
6
2
AF 05
26
AF 5
30
AF 5
37
0
AF
4
AF 00
46
0
AF
58
0
AF
11
6
AF
52
AF
65
AF
80
,
AF
40
AF
16
AF
26
AF
30
,
AF
12
AF
09
AF
38
Millions of
operating
cycles
AF
96
Electrical durability for AC-3 utilization category - Ue ≤ 440 V.
Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current).
Ambient temperature and maximum electrical switching frequency: see "Technical data".
10
5
3
5
9
7
5
3
1
2
1.8
9
7
5
3
1
1
0.5
0.3
1 3 5 7 9
1 3 5 7 9
1
3
5
7
9
1 3 5 7 9
1 5 9
1 5 9
1
3
5
7
9
1 3 579
0.2
2
3
5
10
20
30
50
55
100
200
300
500
1000
Breaking current Ic (A)
1SBC101941S0201
Example:
Motor power 30 kW for AC-3 - Ue = 400 V and Ie = 55 A utilization – Electrical durability required = 1.8 million operating cycles.
For AC-3: Ic = Ie. Select the AF65 contactor at intersection " " (55 A / 1.8 million operating cycles) on the curves (AC-3 - Ue ≤ 440 V).
ABB | 5/139
3-pole contactors
Electrical durability
Electrical durability for AC-3 utilization category - 440 V < Ue ≤ 690 V.
Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current).
Ambient temperature and maximum electrical switching frequency: see "Technical data".
AF1350, AF1650:
The electrical durability at
the rated current is 50000
operating cycles.
AF
AF 37
40 0
AF 0
46
AF 0
58
AF 0
75
0
11
AF 6
14
AF 0
14
6
AF
19
AF 0
20
AF 5
26
AF 5
30
5
AF
5
AF 2
65
AF
AF 80
96
AF
40
AF
26
A
AF F30
38
AF
1
AF 2
16
AF
AF
09
Millions of
operating
cycles
10
5
5
3
9
7
5
3
1
2
9
7
1.5
5
3
1
1
0.5
0.2
1
1 3 5 7 9
2
3
5
10
3
5
7
9
20
1 3 5 7 9
1 5 9
1 3 5 7 9
0.3
1
1 3 579
30
50
3
5
100
7
9
200
140
1 3 579
300
500
1000
Breaking current Ic (A)
1SBC101955S0201
Example:
Motor power 132 kW for AC-3 - Ue = 660 V and Ie = 140 A utilization – Electrical durability required = 1.5 million operating cycles.
For AC-3: Ic = Ie. Select the AF265 contactor at intersection " " (140 A / 1.5 million operating cycles) on the curves (AC-3 - 440 V < Ue
≤ 690 V).
5/140 | ABB
AF09 ... AF96 3-pole contactors
Terminal marking and positioning
AF09 ... AF96 contactors - AC / DC operated
Standard devices without addition of auxiliary contacts
2T1 4T2 6T3
A1 A2
A1 A2
A1 A2
1L1 3L2 5L3
13
1L1 3L2 5L3
21
NO
NC
NO
NC
14
2T1 4T2 6T3
A1 A2
22
2T1
A1 A2
AF09 ... AF16..-30-10
3L2
1L1
4T2
A1
1L1
3L2
5L3
13
NO
A2
2T1
4T2
6T3
NO
14
6T3
AF26 ... AF96..-30-00
A1 A2
1L1 3L2 5L3
5L3
A1 A2
AF09 ... AF16..-30-01
A1 A2
3L2
1L1
AF09 ... AF16..-30-10
13 21 31 43
13 21 31 43
NO
NO
3L2
1L1
13
1L1
3L2
5L3
21
NC
A2
2T1
4T2
6T3
NC
22
AF09 ... AF16..-30-01
A1
1L1
3L2
5L3
A2
2T1
4T2
6T3
AF26 ... AF96..-30-00
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
A1
1L1
3L2
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
A2
2T1
4T2
6T3
NO
14
NC
22
5
A1 A2
A1 A2
5L3
A1
NO
5L3
3L2
1L1
5L3
13X
21X
21
AF09 ... AF96..-30-22
AF26 ... AF38..-30-11
NC
NC
NC
NO
NC
NC
NO
NO
14 22 32 44
14 22 32 44
2T1
2T1 4T2 6T3
4T2
14
6T3
2T1
A1 A2
A1 A2
AF09 ... AF16..-30-22
NC
NC
22X
14X
22
4T2
NO
6T3
2T1
AF26 ... AF96..-30-22
4T2
AF26 ... AF38..-30-11
1L1
3L2
5L3
13X 21X
NO NC
A2
2T1
4T2
6T3
NO NC
14X 22X
6T3
A1 A2
A1 A2
A1
AF40 ... AF96..-30-11
AF40 ... AF96..-30-11
Other possible contact combinations with auxiliary contacts added by the user
A1 A2
1L1 3L2 5L3
NO
21
A1 A2
A1 A2
13
13
1L1
NO
2-
=
NC
22
+
2-
NO
2T1 4T2 6T3
3L2
-1
13 21
NC
NO NC
-2
14 22
A1 A2
5L3
1-
2T1 4T2 6T3
14
14
2T1
A1 A2
4T2
6T3
13
1L1 3L2 5L3
NO
13
NO
A1 21 33
+
22 34 A2
NC
NO
22 34 A2
NO
2T1 4T2 6T3
2T1 4T2 6T3
14
NC NC
NO
NO
NO
13X
21X
=
NC
2T1 4T2 6T3
A1 A2
13
NO
21
NC
NC
A2
2T1
4T2
6T3
NO
14
NC
22
Combination 11
-2
1L1 3L2 5L3
NO
14
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
13
NO
=
21 31 43 53
+
NC
NC
NO
NO
22 32 44 54
Combination 21
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43 53
NO NO
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO NO
44 54
NO
2T1 4T2 6T3
14
A1 A2
Combination 32 = AF09 ... AF16..-30-10 + CA4-22M
Combination 32
A1 A2
13
NC
NO
5L3
6T3
22 32 44 54
2T1 4T2 6T3
A1 A2
22X
14X
-1
+
A1 A2
13
NO
Combination 21 = AF09 ... AF16..-30-10 + CAT4-11M
13X
21X
4T2
NO
NO
14
1L1 3L2 5L3
NO
-4
2-
21 31 43 53
A1 A2
NO
3L2
Combination 11 = AF26 ... AF96..-30-00 + CA4-10 + CA4-01
1L1 3L2 5L3
=
NO
1L1
A1 A2
A1 A2
NC
+
2T1
A1 A2
Combination 11 = AF09 ... AF16..-30-10 + CA4-01
A1 21 33
-3
2-
=
1-
A1
5L3
NO
A1 A2
1L1 3L2 5L3
3L2
1L1
NC
NC
NO
22X
14X
14
NO
1L1 3L2 5L3
13
NO
+
A1
1L1
3L2
5L3
13 13X 21X
NO NO NC
A2
2T1
4T2
6T3
NO NO NC
14 14X 22X
NO
2T1 4T2 6T3
14
A1 A2
Combination 21 = CAL4-11 + AF09 ... AF16..-30-10
Combination 21
Note: Only AF..Z contactor with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for
the negative pole
ABB | 5/141
1SBC101463S0201 - Rev. A
1L1 3L2 5L3
AF116 ... AF370 3-pole contactors
Terminal marking and positioning
AF116 ... AF370 contactors - AC / DC operated
Standard devices without addition of auxiliary contacts
3L2
1L1
A1
A2
2T1
4T2
6T3
AF116 ... AF370-30-00
A1
1L1 3L2
5L3
A2
2T1 4T2
6T3
AF116 ... AF370-30-00
Standard devices with factory mounted auxiliary contacts
3L2
1L1
A1
NO 13X
5L3
A2
3L2
1L1
A1
NO 13X
5L3
A2
43X NO
NC 21X
31X NC
NC 22X
NC 22X
32X NC
NO 14X
NO 14X
44X NO
NC 21X
2T1
4T2
AF116 ... AF370-30-11
6T3
2T1
4T2
AF116 ... AF370-30-22
A1
1L1 3L2
5L3
A2
2T1 4T2
6T3
13X
NO
21X
NC
NO
14X
NC
22X
A1
1L1
3L2
5L3
13X
NO
21X
NC
31X
NC
43X
NO
A2
2T1
4T2
6T3
NO
14X
NC
22X
NC
32X
NO
44X
6T3
AF116 ... AF370-30-11
AF116 ... AF370-30-22
1SFC101130C0201
5
5L3
5/142 | ABB
AF400 ... AF2650 3-pole contactors
Terminal marking and positioning
AF400 ... AF1250 contactors - AC / DC operated
Standard devices with factory mounted auxiliary contacts
1L1
3L2
5L3
1L1
3L2
5L3
Control with logic signal
X5
Logic
signal
1
2
3
A2
0V
X5
Supply voltage
24V
+
A1
ON
1
OFF
OFF_N
2
NO 13X
NO 13X
43X NO
NC 21X
NC 21X
31X NC
NC 22X
NC 22X
32X NC
NO 14X
NO 14X
44X NO
4T2
2T1
6T3
2T1
AF400 ... AF1250-30-11
4T2
AF400 ... AF1250-30-11, AF400 ... AF1250-30-22
6T3
A1
1L1 3L2
5L3
A2
2T1 4T2
6T3
13X
NO
21X
NC
NO
14X
NC
22X
AF400 ... AF1250-30-11
AF1350 ... AF2650 contactors - AC / DC operated
Standard devices with factory mounted auxiliary contacts
3L2
COMMON
3
AF400 ... AF1250-30-22
1L1
A2
Contactor
X5
ON
A1
1L1
3L2
5L3
13X
NO
21X
NC
31X
NC
43X
NO
A2
2T1
4T2
6T3
NO
14X
NC
22X
NC
32X
NO
44X
AF400 ... AF1250-30-22
Wiring diagrams
when used with transistor output
5L3
0V
Supply voltage
24V
+
A1
1
A2
OFF
A2
1L1 3L2
2T1 4T2
5L3
6T3
13X 21X
NO NC
NO
14X
NC
22X
2
3
E2139D3
A1
A2
Contactor
X5
ON
A1
5
ON
OFF_N
COMMON
AF1350, AF1650
AF1350, AF1650-30-11
AF1350 ... AF2650-30-11
NO 13X
NC 21X
when used with transistor output
NO 22X
NO 14X
0V
2T1
4T2
3L2
5L3
6T3
A2
AF1350 ... AF2650-30-11
1L1
2T1 4T2 6T3
13X 21X 31X 43X
NO NC NC NO
NO NC NC NO
14X 22X 32X 44X
+
A1
X5
ON
E2138D3
A1
Supply voltage
24V
1
OFF
2
3
AF1350,...AF1650-30-22
AF1350
AF2650-30-22
A2
Contactor
ON
OFF_N
COMMON
AF1350, AF1650
1SFC101131C0201
1
2
3
A1
E1689D2G
Logic
signal
A2
E2693DG
A1
ABB | 5/143
AF09, AF12, AF16 3-pole contactors
5.5 0.22"
5.5 0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
6 0.24"
80 3.15"
80 3.15"
6 0.24"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
5.5 0.22"
10 0.39"
35 1.38"
2x
ø 4.2 0.17"
M4 8-32 UNC
2x
M4 8-32 UNC
70 2.76"
71 2.80"
5 0.20"
77 3.03"
71 2.80"
70 2.76"
77 3.03"
5 0.20"
45 1.77"
60 2.36"
45 1.77"
mm, inches
60 2.36"
Main dimensions
10 0.39"
5 0.20"
5 0.20"
AF09, AF12, AF16
AF09, AF12, AF16
5
110.5 4.35"
71 2.80"
45 1.77"
77 3.03"
10 0.39"
12 0.47"
71 2.80"
80 3.15"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
45 1.77"
5.5 0.22"
10 0.39"
AF09, AF12, AF16
+ CA4, CC4 1-pole auxiliary contact block
AF09, AF12, AF16
+ CAL4-11 2-pole auxiliary contact block
102.5 4.04"
110.5 4.35"
71 2.80"
10 0.39"
45 1.77"
5.5 0.22"
AF09, AF12, AF16
+ CA4 4-pole auxiliary contact block
5.5 0.22"
AF09, AF12, AF16
+ CAT4 2-pole auxiliary contact and coil terminal block
133.5 5.26"
110.5 4.35"
5 0.20"
80 3.15"
70 2.76"
60 2.36"
5.5 0.22"
5 0.20"
AF09, AF12, AF16..-30-22
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/144 | ABB
10 0.39"
5.5 0.22"
1.1 0.04"
6 0.24"
ø 4.2 0.17"
43 1.69"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
71 2.80"
2 x45 1.77"
M4 8-32 UNC
AF09, AF12, AF16
+ TEF4 electronic timer
5.5 0.22"
1SBC101682S0201 - Rev. A
35 1.38"
40.5 1.59"
10 0.39"
35 mm EN/IEC 60715
71 2.80"
45 1.77"
10 0.39"
5.5 0.22"
35 mm EN/IEC 60715
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
71 2.80"
45 1.77"
AF09, AF12, AF16 3-pole contactors
Main dimensions
mm, inches
102.5
4.04"
102.5
4.04"
90 90
3.54"
3.54"
71 71
2.80"
2.80"
10 10
0.39"
0.39"
2 x2 x
M4M4
8-32
UNC
8-32
UNC
80 80
3.15"
3.15"
70 2.76"
70 2.76"
5 0.20"
5 0.20"
5.55.5
0.22"
0.22"
60 2.36"
60 2.36"
43 1.69"
43 1.69"
ø 4.2
0.17"
ø 4.2
0.17"
AF09, AF12, AF16
+ VEM4 mechanical and electrical interlock set
77 3.03"
5.5 0.22"
5 0.20"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
ø 4.2 0.17"
ø 4.2 0.17"
2x
M4 8-32 UNC
70 2.76"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
156.1 6.15"
80 3.15"
6 0.24"
5.5 0.22"
5
35 1.38"
35 1.38"
60 2.36"
71 2.80"
60 2.36"
45 1.77"
10
5.5
0.22"
0.39"
71 2.80"
5 0.20"
77 3.03"
45 1.77"
5 0.20"
5 0.20"
AF09, AF12, AF16
+ VEM4 mechanical and electrical interlock set
5 0.20"
91.5 3.60"
91.5 3.60"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5.55.5
0.22"
0.22"
10 0.39"
5 0.20"
6.2
0.24"
AF09, AF12, AF16
+ TF42, EF19
72.7 2.86"
76.8 3.02"
AF09, AF12, AF16
+ TF42 thermal overloard relay
77 3.03"
71 2.80"
45 1.77"
10 0.39"
35 mm EN/IEC 60715
152.4 6.00"
5.5 0.22"
5.5 0.22"
17.4 0.69"
73.3 2.89"
1SBC101682S0201 - Rev. A
76.8 3.02"
AF09, AF12, AF16 3-pole contactors
+ EF19 electronic overload relay
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/145
AF26, AF30, AF38 3-pole contactors
5.5 0.22"
10 0.39"
10 0.39"
5 0.20"
AF26, AF30, AF38
35 1.38"
2x
ø 4.2 0.17"
M4 8-32 UNC
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
60 2.36"
ø 4.2 0.17"
5 0.20"
35 1.38"
71 2.80"
5.5 0.22"
35 mm EN/IEC 60715
80 3.15"
35 mm EN/IEC 60715
6 0.24"
6 0.24"
5.5 0.22"
80 3.15"
77 3.03"
80 3.15"
45 1.77"
5 0.20"
86 3.39"
45 1.77"
70 2.76"
mm, inches
60 2.36"
Main dimensions
5 0.20"
AF26, AF30, AF38
5
119.5 4.70"
45 1.77"
80 3.15"
86 3.39"
10 0.39"
12 0.47"
80 3.15"
45 1.77"
5.5 0.22"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
AF26, AF30, AF38
+ CAL4-11 2-pole auxiliary contact block
AF26, AF30, AF38
+ CA4, CC4 1-pole auxiliary contact block
119.5 4.70"
111.5 4.39"
10 0.39"
45 1.77"
80 3.15"
43 1.69"
AF26, AF30, AF38
+ CA4 4-pole auxiliary contact block
111.5 4.39"
142.5 5.61"
45 1.77"
10 0.39"
80 3.15"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/146 | ABB
1.1 0.04"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
AF26, AF30, AF38..-30-11
AF26, AF30, AF38..-30-22
43 1.69"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
5.5 0.22"
10 0.39"
5.5 0.22"
5.5 0.22"
AF26, AF30, AF38
+ TEF4 electronic timer
5.5 0.22"
1SBC101683S0201 - Rev. A
119.5 4.70"
AF..-30-11
80 3.15"
5.5 0.22"
AF26, AF30, AF38
+ CAT4 2-pole auxiliary contact and coil terminal block
AF..-30-22
45 1.77"
10 0.39"
5.5 0.22"
40.5 1.59"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
45 1.77"
AF26, AF30, AF38 3-pole contactors
Main dimensions
mm, inches
111.5
111.54.39"
4.39"
90903.54"
3.54"
80803.15"
3.15"
10100.39"
0.39"
2 2x x
M48-32
8-32UNC
UNC
M4
80803.15"
3.15"
5.5
5.50.22"
0.22"
70 2.76"
70 2.76"
5 0.20"
5 0.20"
60 2.36"
60 2.36"
43 1.69"
43 1.69"
91.5 3.60"
91.5 3.60"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
5.5
5.50.22"
0.22"
ø ø4.2
4.20.17"
0.17"
5 0.20"
9.2
0.36"
5
2x
M4 8-32 UNC
70 2.76"
ø 4.2 0.17"
60 2.36"
5.5 0.22"
35 1.38"
210
x
0.39"UNC
M4 8-32
70 2.76"
35 mm EN/IEC 60715
5.5 0.22"
158.9 6.26"
158.9 6.26"
35 mm EN/IEC 60715
5.5 0.22"
5 0.20"
86 3.39"
35 1.38"
10
80 3.15"
0.39" 5.5 0.22"
ø 4.2 0.17"
45 3.15"
1.77"
80
60 2.36"
86 3.39"
45 1.77"
AF26, AF30, AF38
+ VEM4 mechanical and electrical interlock set
5 0.20"
AF26, AF30, AF38
+ VEM4 mechanical and electrical interlock set
5 50.20"
0.20"
5 0.20"
9.2
0.36"
AF26, AF30, AF38
+ TF42, EF19, EF45
75.7 2.98"
75.7 2.98"
79.8 3.14"
79.8 3.14"
AF26, AF30, AF38
+ TF42 thermal overload relay
86 3.39"
45 1.77"
80 3.15"
86 3.39"
10 0.39"
45 1.77"
80 3.15"
10 0.39"
35 mm EN/IEC 60715
5.5 0.22"
5.5 0.22"
5.5 0.22"
172.3 6.78"
35 mm EN/IEC 60715
155.2 6.11"
5.5 0.22"
20.4 0.80"
76.3 3.00"
82.5 3.25"
1SBC101683S0201 - Rev. A
79.8 3.14"
AF26 3-pole contactors
+ EF19 electronic overload relay
86 3.39"
AF26, AF30, AF38 3-pole contactors
+ EF45 electronic overload relay
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/147
AF40 ... AF65 3-pole contactors
Main dimensions
111 4.37"
45 1.77"
ø 6.4 0.25"
7 0.28"
6 0.24"
55 2.17"
mm, inches
110 4.33"
4.6 0.18"
5.5 0.22"
10 0.39"
5 0.20"
AF40, AF52, AF65
AF40, AF52, AF65
144 5.67"
111 4.37"
10 0.39"
12 0.47"
7 0.28"
111 4.37"
55 2.17"
7 0.28"
6 0.24"
6 0.24"
55 2.17"
5.5 0.22"
35 mm EN/IEC 60715
119.5 4.70"
43 1.69"
119.5 4.70"
35 mm EN/IEC 60715
5.5 0.22"
10 0.39"
AF40, AF52, AF65
+ CA4, CC4 1-pole auxiliary contact block
AF40, AF52, AF65-30-00 + CAL4-11 2-pole auxiliary contact block
AF40, AF52, AF65-30-11
144 5.67"
111 4.37"
136 5.35"
10
0.39"
111 4.37"
10 0.39"
7 0.28"
55 2.17"
7 0.28"
AF40, AF52, AF65
+ CA4 4-pole auxiliary contact block
43 1.69"
35 mm EN/IEC 60715
5.5 0.22"
119.5 4.70"
43 1.69"
5.5 0.22"
AF40, AF52, AF65
+ CAT4 2-pole auxiliary contact and coil terminal block
144 5.67"
167 6.57"
55 2.17"
7 0.28"
AF40, AF52, AF65..-30-22
5/148 | ABB
111 4.37"
6 0.24"
AF40, AF52, AF65
+ TEF4 electronic timer
1.1 0.04"
35 mm EN/IEC 60715
119.5 4.70"
43 1.69"
35 mm EN/IEC 60715
5.5 0.22"
10 0.39"
7 0.28"
5.5 0.22"
40.5 1.59"
10 0.39"
6 0.24"
55 2.17"
111 4.37"
1SBC101731S0201
119.5 4.70"
35 mm EN/IEC 60715
6 0.24"
55 2.17"
119.5 4.70"
5
2x
M4 8-32 UNC
100 3.94"
119.5 4.70"
35 mm EN/IEC 60715
ø 4.2 0.17"
2x
M6 ¼-20 UNC
AF40 ... AF65 3-pole contactors
Main dimensions
mm, inches
111 4.37"
110 4.33"
M6 ¼-20 UNC
100 3.94"
6 0.24"
7 0.28"
ø 4.2 0.17"
10 0.39"
ø 6.4 0.25"
AF40, AF52, AF65
+ VM96-4 mechanical interlock unit
10 0.39"
55 2.17"
5
111 4.37"
4 0.16"
10 0.39"
7 0.28"
35 mm EN/IEC 60715
5.5 0.22"
237 9.33"
35 mm EN/IEC 60715
7 0.28"
208.5 8.21"
5 0.20"
AF40, AF52, AF65
+ VM96-4 mechanical interlock set
111 4.37"
55 2.17"
4.6 0.18"
5.5 0.22"
100 3.94"
110 4.33"
119.5 4.70"
35 x 15 mm EN/IEC 60715
M4 8-32 UNC
5.5 0.22"
5.4 0.21"
106.8 4.20"
110.6 4.35"
AF40, AF52, AF65
+ TF65 thermal overload relay
70 2.76"
106.8 4.20"
110.6 4.35"
AF40, AF52, AF65
+ EF65 electronic overload relay
45 1.77"
ø 6.4 0.25"
4.6 0.18"
110 4.33"
2x
M4 8-32 UNC
100 3.94"
ø 4.2 0.17"
2x
M6 ¼-20 UNC
5 0.20"
1SBC101731S0201
AF40, AF52, AF65
+ TF65, EF65
ABB | 5/149
AF80 ... AF96 3-pole contactors
Main dimensions
mm, inches
60 2.36"
116 4.57"
70 2.76"
ø 6.4 0.25"
2x
M6 ¼-20 UNC
110 4.33"
4.6 0.18"
5.5 0.22"
100 3.94"
119.5 4.70"
35 x 15 mm EN/IEC 60715
6 0.24"
7 0.28"
10 0.39"
5 0.20"
AF80, AF96
AF80, AF96
5
149 5.87"
116 4.57"
70 2.76"
10
12 0.47"
0.39"
116 4.57"
70 2.76"
7 0.28"
6 0.24"
6 0.24"
7 0.28"
5.5 0.22"
35 x 15 mm EN/IEC 60715
119.5 4.70"
43 1.69"
119.5 4.70"
35 x 15 mm EN/IEC 60715
5.5 0.22"
10 0.39"
AF80, AF96-30-00 + CAL4-11 2-pole auxiliary contact block
AF80, AF96-30-11
AF80, AF96
+ CA4, CC4 1-pole auxiliary contact block
149 5.87"
116 4.57"
10
0.39"
7 0.28"
43 1.69"
119.5 4.70"
35 x 15 mm EN/IEC 60715
6 0.24"
70 2.76"
5.5 0.22"
AF80, AF96
+ CA4 4-pole auxiliary contact block
172 6.77"
149 5.87"
10
0.39"
5/150 | ABB
AF80, AF96
+ TEF4 electronic timer
5.5 0.22"
40.5 1.59"
1.1 0.04"
35 x 15 mm EN/IEC 60715
119.5 4.70"
43 1.69"
35 x 15 mm EN/IEC 60715
119.5 4.70"
AF80, AF96..-30-22
5.5 0.22"
10 0.39"
7 0.28"
6 0.24"
7 0.28"
116 4.57"
70 2.76"
1SBC101732S0201
116 4.57"
6 0.24"
70 2.76"
AF80 ... AF96 3-pole contactors
Main dimensions
mm, inches
116 4.57"
140 5.51"
7 0.28"
M6 ¼-20 UNC
4.6 0.18"
5.5 0.22"
10 0.39"
ø 6.4 0.25"
AF80, AF96
+ VM96-4 mechanical interlock unit
10 0.39"
5
10 0.39"
35 x 15 mm EN/IEC 60715
7 0.28"
5.5 0.22"
237 9.33"
35 x 15 mm EN/IEC 60715
116 4.57"
70 2.76"
7 0.28"
211 8.31"
5 0.20"
AF80, AF96
+ VM96-4 mechanical interlock set
116 4.57"
70 2.76"
100 3.94"
110 4.33"
119.5 4.70"
35 x 15 mm EN/IEC 60715
6 0.24"
130 5.12"
4 0.16"
5.5 0.22"
5.4 0.21"
106.8 4.20"
110.9 4.37"
AF80, AF96
+ TF96 thermal overload relay
60 2.36"
2x
M6 ¼-20 UNC
4.6 0.18"
110 4.33"
110.6 4.35"
AF80, AF96
+ EF96 electronic overload relay
100 3.94"
ø 6.4 0.25"
106.8 4.20"
5 0.20"
1SBC101732S0201
AF80, AF96
+ TF96, EF96
ABB | 5/151
AF116, AF140, AF146 3-pole contactors
Main dimensions
mm, inches
3 0.12"
14.2 0.56"
20 0.79"
14.2 0.56"
SECTION D-D
14.2 0.56"
SECTION E-E
E
30 1.18"
126 4.96"
90 3.54"
D
M4 8-32 UNC
100 3.94"
19.5 4.96"
150 5.91"
55.5 0.22"
D
30 1.18"
AF116, AF140, AF146-30-00 + CAL19 2-pole auxiliary contact block
AF116, AF140, AF146-30-11
AF116, AF140, AF146-30-..(B)
SECTION D-D
22.8 0.90"
3 0.12"
5.5 0.22"
ø 6.5 0.26"
20 0.79"
23.8 0.94"
23.8 0.94"
SECTION E-E
E
90 3.54"
D
30 1.18"
AF116, AF140, AF146-30-00B + CAL19 2-pole auxiliary contact block
AF116, AF140, AF146-30-11B
5/152 | ABB
1SFC101118C0201
55.5 2.18"
D
126 4.96"
19.5 0.77"
10 0.39"
150 5.91"
5
10 0.39"
AF116, AF140, AF146 3-pole contactors
With built-in PLC interface (coil code 33, 34)
Main dimensions
mm, inches
3 0.12"
14.2 0.56"
20 0.79"
14.2 0.56"
SECTION D-D
14.2 0.56"
SECTION E-E
E
10 0.39"
30 1.18"
142.5 5.61"
90 3.54"
D
M4 8-32 UNC
5
100 3.94"
19.5 4.96"
150 5.91"
55.5 0.22"
D
30 1.18"
AF116, AF140, AF146-30-00 + CAL19 2-pole auxiliary contact block
AF116, AF140, AF146-30-11
AF116, AF140, AF146-30-..(B)
SECTION D-D
22.8 0.90"
3 0.12"
5.5 0.22"
ø 6.5 0.26"
20 0.79"
23.8 0.94"
23.8 0.94"
SECTION E-E
E
90 3.54"
D
1SFC101118C0201
150 5.91"
55.5 2.18"
D
142.5 5.61"
19.5 0.77"
10 0.39"
30 1.18"
AF116, AF140, AF146-30-00B + CAL19 2-pole auxiliary contact block
AF116, AF140, AF146-30-11B
ABB | 5/153
180 7.09"
17 0.67"
ø 6.4 0.25"
8 0.31"
13 0.51"
126 4.96"
3 0.12"
17 0.67"
126 4.96"
3 0.12"
30 1.18"
AF116, AF140, AF146-30-11(B)
+ LW140(B) terminal enlargement
126 4.96"
8x
126 4.96"
30 1.18"
60 2.36"
30 1.18"
M4 8-32 UNC
AF116, AF140, AF146-30-11(B)
+ VM19 mechanical interlocking unit
1SFC101118C0201
AF116, AF140, AF146-30-11(B)
+ VM19 mechanical interlocking unit
7.5 0.3"
24 0.94"
90 3.54"
ø 6 0.24"
226 8.90"
29.5 1.16"
228 8.98"
108 4.25"
15 0.59"
41 1.61"
AF116, AF140, AF146-30-11
+ LX140 terminal extension
180 7.09"
126 4.96"
3 0.12"
100 3.94"
30 1.18"
233 9.17"
ø 6.4 0.25"
AF..-30-11
13 0.51"
17 0.67"
AF..-30-11B
90 3.54"
226 8.90"
5
mm, inches
8 0.31"
24 0.94"
Main dimensions
150 5.91"
150 5.91"
AF116, AF140, AF146 3-pole contactors
5/154 | ABB
AF116, AF140, AF146 3-pole contactors
Main dimensions
mm, inches
126 4.96"
17 0.67"
30 1.18"
3 0.12"
4x
M4 8-32 UNC
100 3.94"
90 3.54"
45 1.77"
259 10.20"
5
82.3 3.24"
6 0.24"
4x
M5 10-24 UNC
37 1.46"
8 0.31"
50 1.97"
AF116, AF140-30-11(B)
+ TF140 thermal overload relay
AF116, AF140-30-11(B)
+ TF140 thermal overload relay
126 4.96"
17 0.67"
6x
M4 8-32 UNC
3 0.12"
46 1.81"
270 10.63"
100 3.94"
90 3.54"
30 1.18"
21.5
105 4.13"
AF116, AF140, AF146-30-11(B)
+ EF146 electronic overload relay
37 1.46"
1SFC101118C0201
94.7 3.73"
0.85"
2x
M5 10-24 UNC
AF116, AF140, AF146-30-11(B)
+ EF146 electronic overload relay
ABB | 5/155
AF190, AF205 3-pole contactors
Main dimensions
mm, inches
SECTION B-B
152 5.98"
B
105 4.13"
ø 8.5 0.33"
5 0.20"
35 1.38"
165 6.50"
196 7.72"
5
4X
M5 10-24 UNC
29.5 1.16"
35.5 1.40"
83.5 3.29"
10 0.39"
35 1.38"
AF190, AF205
AF190, AF205-30-00 + CAL19 2-pole auxiliay contact block
AF190, AF205-30-11
105 4.13"
125
1524.92"
5.98"
5 0.20"
20
0.79"
152 5.98"
ø 10.5 0.41"
27 1.06"
10 0.39"
30.5 1.20"
5 0.20"
45 1.77"
AF190, AF205-30-11
+ LW185 terminal enlargement
1SFC101119C0201
299 11.77"
299 11.77"
35 1.38"
AF190, AF205-30-11
+ LX185 terminal extension
5/156 | ABB
30.5 1.20"
10 0.37"
ø 8.5 0.33"
27 1.06"
17.5 0.69"
AF190, AF205 3-pole contactors
With built-in PLC interface (coil code 33, 34)
Main dimensions
mm, inches
SECTION B-B
169.5 6.67"
B
35.5 1.40"
5 0.20"
196 7.72"
83.5 3.29"
ø 8.5 0.33"
29.5 1.16"
105 4.13"
10 0.39"
5
35 1.38"
AF190, AF205-30-00 + CAL19 2-pole auxiliay contact block
AF190, AF205-30-11
4X
M5 10-24 UNC
165 6.50"
35 1.38"
1SFC101119C0201
AF190, AF205
ABB | 5/157
AF190, AF205 3-pole contactors
Main dimensions
mm, inches
152 5.98"
196 7.727"
210 8.27"
5
AF190, AF205-30-11
+ VM19 mechanical interlocking unit
70 2.76"
35 1.38"
6X
M5 10-24 UNC
165 6.50"
35 1.38"
1SFC101119C0201
AF190, AF205
+ VM19 mechanical interlocking unit
5/158 | ABB
AF190, AF205 3-pole contactors
Main dimensions
mm, inches
152 5.98"
105 4.13"
35.5 1.40"
5 0.20"
8x
M5 10-24 UNC
165 6.50"
35 1.39"
11 0.43"
21 0.83"
82 3.23"
25.5
1.0"
312.5 12.3"
5
37 1.46"
20 0.79"
42.5 1.67"
AF190, AF205-30-11
+ TA200DU thermal overload relay
62 2.44"
4 0.16"
50 1.97"
126 4.96"
AF190, AF205
+ TA200DU thermal overload relay
1SFC101119C0201
ø 11 0.43"
ABB | 5/159
AF190, AF205 3-pole contactors
Main dimensions
mm, inches
152 5.98"
105 4.13"
8x
M5 10-24 UNC
5 0.20"
165 6.50"
35.5 1.40"
20.5
35 1.38"
10 0.39"
112 4.42"
0.81"
342 13.46"
5
17.5 0.69"
35 1.38"
35 1.38"
8.5 0.33"
5 0.20"
123 4.84"
AF190, AF205
+ EF205 electronic overload relay
1SFC101119C0201
AF190, AF205-30-11
+ EF205 electronic overload relay
35 1.39"
5/160 | ABB
AF265, AF305, AF370 3-pole contactors
Main dimensions
mm, inches
A
140 5.51"
180 7.09"
19.5 0.77"
35.5 1.40"
94.7 3.73"
ø 10.5 0.41"
5 0.20"
33.4 1.31"
10 0.39"
225 8.86"
5
43.75 1.72"
AF265, AF305, AF370-30-00 + CAL19 2-pole contact block
AF265, AF305, AF370-30-11
4X
M5 10-24 UNC
1SFC101120C0201
187 7.36"
43.75 1.72"
AF265, AF305, AF370
ABB | 5/161
AF265, AF305, AF370 3-pole contactors
With built-in PLC interface (coil code 33, 34)
Main dimensions
mm, inches
A
140 5.51"
19.5 0.77"
195.5 7.70"
94.7 3.73"
ø 10.5 0.41"
5 0.20"
225 8.86"
5
35.5 1.40"
33.4 1.31"
10 0.39"
43.75 1.72"
AF265, AF305, AF370-30-00 + CAL19 2-pole contact block
AF265, AF305, AF370-30-11
4X
M5 10-24 UNC
AF265, AF305, AF370
5/162 | ABB
1SFC101120C0201
187 7.36"
43.75 1.72"
AF265, AF305, AF370 3-pole contactors
mm, inches
165 6.50"
180 7.09"
5 0.79"
0.20"
30.5 1.20"ø 10.5200.41"
20 0.79"
180 7.09"
ø 10.5 0.41"
12.5 0.49"
32.0 1.28"
12.5 0.49"
32.0 1.28"
ø 10.5 0.41"
31.2 1.23"
25 0.98"
30.5 1.20"
30.5 1.20"
5 0.20"
180 7.09"
5 0.20"
12.5 0.49"
Main dimensions
AF265, AF305, AF370-30-11
+ LX300 terminal extension
43.75 1.72"
43.75 1.72"
AF265, AF305, AF370-30-11
+ LW300 terminal enlargement
1SFC101120C0201
62 2.44"
354.5 20.02"
354.5 20.02"
354.5 13.96"
5
ABB | 5/163
AF265, AF305, AF370 3-pole contactors
Main dimensions
mm, inches
180 7.09"
AF265, AF305, AF370-30-11
+ VM19 mechanical interlocking unit
43.75 1.72"
96.25 3.79"
43.75 1.72"
8X
M5 10-24 UNC
187 7.36"
AF265, AF305, AF370
+ VM19 mechanical interlocking unit
1SFC101120C0201
5
225 8.86"
280 11.02"
5/164 | ABB
AF265, AF305, AF370 3-pole contactors
Main dimensions
mm, inches
180 7.09"
35.5 1.40"
8x
M5 10-24 UNC
5 0.20"
5
ø 11 0.43"
44 1.73"
20 1.79"
43.8 1.72"
14 0.55"
112 4.41"
29 1.14"
385 15.16"
187 7.36"
140 5.51"
35 1.38"
43.75 1.72"
35 1.20"
5 0.20"
123 4.84"
AF265, AF305, AF370
+ EF370 electronic overload relay
1SFC101120C0201
AF265, AF305, AF370-30-11
+ EF370 electronic overload relay
ABB | 5/165
AF400 and AF460 3-pole contactors
Main dimensions
ø6.5
0.26"
ø10.5
0.41"
216 8.5"
48.5 1.91"
6 0.24"
63 2.48"
248 9.76"
268 10.55"
M5 10-24 UNC
63 2.48"
AF400, AF460-30-11
AF400, AF460
216 8.5"
181 7.13"
ø10 0.39"
44 1.73"
5 0.2"
63 2.48"
AF400, AF460-30-11
+ LX460 terminal extension
5/166 | ABB
78 3.07"
AF400, AF460-30-11
+ LW460 terminal enlargement
1SFC101121C0201
472 18.58"
139 5.47"
25 0.98"
12
0.47"
33 1.3"
ø 10.5 0.41"
11.5
0.45"
33 1.3"
186 7.32"
25 0.98"
472 18.58"
5
22.5
0.89"
278 10.94"
25
0.98"
11.5 0.45"
mm, inches
186 7.32"
AF400 and AF460 3-pole contactors
Main dimensions
mm, inches
216 8.5"
402 15.83"
ø10.5 0.41"
48.5 1.91"
30
1.18"
6 0.24"
278 10.94"
268 10.55"
25 0.98"
5
63 2.48"
AF400, AF460-30-11
+ VM750H mechanical interlock unit
63 2.48"
248 9.76"
216 8.5"
M5 10-24 UNC
1SFC101121C0201
AF400, AF460
+ VM750H mechanical interlock unit
ABB | 5/167
AF400 and AF460 3-pole contactors
Main dimensions
mm, inches
216 8.5"
186 7.32"
63 2.48"
63 2.48"
ø10.5
0.41"
48.5 1.91"
6 0.24"
248 9.76"
25 0.98"
449.5 17.7"
454.5 17.89"
5
M5 10-24 UNC
11.5 0.45"
55 2.17"
6.5 0.26"
83 3.27"
63 2.48"
6.5 0.26"
ø10.5 0.41"
63 2.48"
25 0.98"
63 2.48"
M5 10-24 UNC
46 1.81"
76 2.99"
5 0.2"
148 5.83"
192 7.56"
AF400, AF460
+ E500DU electronic O/L relay
1SFC101121C0201
AF400, AF460-30-11
+ E500DU electronic O/L relay
5/168 | ABB
AF580 and AF750 3-pole contactors
mm, inches
210 8.27"
22.5
0.89"
ø6.5
0.26"
ø12.5
0.49"
242 9.53"
48.5 1.91"
6 0.24"
283 11.14"
273 10.75"
40 1.57"
11.5 0.45"
Main dimensions
5
72 2.83"
AF580 and AF750-30-11
249 9.8"
72 2.83"
M6 1/4-20 UNC
1SFC101122C0201
AF580 and AF750
ABB | 5/169
AF580 and AF750 3-pole contactors
Main dimensions
mm, inches
210 8.27"
242 9.53"
43 1.69"
6 0.24"
483 19.02"
141.5 5.57"
5
9.6 0.38"
105 4.13"
35.5
1.4"
ø13 0.51"
11.5
0.45"
22.5
0.89"
40 1.57"
72 2.83"
1SFC101122C0201
AF580 and AF750-30-11
+ LX750 terminal extension
5/170 | ABB
AF580 and AF750 3-pole contactors
mm, inches
245 9.65"
40 1.57"
242 9.53"
43 1.69"
6 0.24"
9.6 0.38"
35
1.38"
ø13 0.51"
11 0.43"
Main dimensions
483 19.02"
141.5 5.57"
5
92 3.62"
1SFC101122C0201
AF580 and AF750-30-11
+ LW750 terminal enlargement
ABB | 5/171
AF580 and AF750 3-pole contactors
Main dimensions
mm, inches
210 8.27"
72 2.83"
ø12.5
0.49"
242 9.53"
48.5 1.91"
6 0.24"
72 2.83"
249 9.8"
40 1.57"
11.5 0.45"
72 2.83"
471.5 18.56"
M6 1/4-20 UNC
5 0.2"
11.5
0.45"
80 3.15"
5 0.2"
79 3.11"
466.6 18.37"
5
ø12.5 0.49"
83 3.27"
83 3.27"
40 1.57"
M6 1/4-20 UNC
60.5 2.38"
82 3.23"
5 0.2"
190 7.48"
245 9.65"
AF580 and AF750
+ E800DU electronic O/L relay
1SFC101122C0201
AF580 and AF750-30-11
+ E800DU electronic O/L relay
5/172 | ABB
AF580 and AF750 3-pole contactors
Main dimensions
mm, inches
450
25
242
30
48.5
6
283
273
ø12.5
E2042D
E2041D
5
72
AF580 and AF750-30-11
+ VM 750H mechanical interlock unit
72
249
240
(M6)
E2043D
(M6)
1SFC101122C0201
AF580 and AF750
+ VM 750H mechanical interlock unit
ABB | 5/173
AF1250 3-pole contactors
Main dimensions
mm, inches
50 1.97"
27
72 2.83"
ø 7 0.28"
242 9.53"
72 2.83"
210 8.27"
46.5
18.3"
8 0.31"
1SFC101125F0001
72 2.83"
ø13 0.51"
1SFC101124F0001
249 9.8"
263 10.35"
313 12.32"
AF1250-30-11
72 2.83"
AF1250
5/174 | ABB
1SFC101136C0201
M6 1/4-20 UNC
1SFC101130F0001
249 9.8"
5
344 13.54"
1.06"
AF1250 3-pole contactors
Main dimensions
mm, inches
72 2.83"
ø13 0.51"
53.8 2.12"
242 9.53"
15 0.59"
50 1.97"
479 18.86"
443 17.44"
AF1250-30-11
+ LW1250 terminal enlargement
37
1.46"
10 0.39"
1SFC101136C0201
240 9.45"
1SFC101131F0001
95 3.74"
95 3.74"
1SFC101132F0001
34
1.34"
249 9.8"
263 10.35"
5
ABB | 5/175
AF1350, AF1650, AF2050 and AF2650 3-pole contactors
Main dimensions
40 1.57"
13 0.51"
AF1350, AF1650
136 5.35"
30 1.18"
13
0.51"
10 0.39"
AF1350, AF1650
40
1.57"
17 0.67"
10 0.39"
ø 13
0.51"
17 0.67"
13
30 1.18"
0.51"
10 0.39"
AF2050
136 5.35"136 5.35"
40
1.57"
17 0.67"
136 5.35"
47
30 1.18"
10 0.39"
AF2050
244 9.61"
10 0.39"
136 5.35"
10 0.39"
1.85"
136 5.35" 80 ø9 0.35"136 5.35"
3.15"
101
3.98"
438 17.24"
438 17.24"
40
312 12.28"
312 12.28"
392 15.43"
80
3.15"
101
3.98"
ø9 0.35"
M8 5/16-18 UMC
AF1350, AF1650, AF2050
AF1350, AF1650, AF2050-30-11
40
ø 13
0.51"
1.57"
40
1.57"
17 0.67"
17 0.67"
40 1.57"
40 1.57"
AF2650
244 9.61"
53
25 0.98"
80
3.15"
101
3.98"
136 5.35" 80 ø9 0.35"136 5.35"
3.15"
101
3.98"
438 17.24"
438 17.24"
136 5.35"
25 0.98"
2.09"
312 12.28"
312 12.28"
422 16.61"
2.09"
244 9.61"
53
312 12.28"
136 5.35"
ø9 0.35"
40
136 5.35"136 5.35"
1.57"
136 5.35"
40
AF2650
1.57"
ø 13
0.51"
422 16.61"
AF2650
M8 5/16-18 UMC
AF2650-30-11
1SFC101123C0201 - Rev. B
5
392 15.43"
1.85"
244 9.61"
47
312 12.28"
17 0.67"
13 0.51"
30 1.18"
40
27
ø 13
1.06"
0.51"
1.06"
1.57"
27
1.57"
40 1.57"
mm, inches
5/176 | ABB
AF1350, AF1650, AF2050 and AF2650 3-pole contactors
Main dimensions
mm, inches
244 9.61"
438 17.24"
M8 5/16-18 UNC
10 0.39"
136
5.35"
93
3.66"
674 26.54"
312 12.28"
47 1.85"
170 6.69"
5
M6 1/4-20 UNC
20 0.79"
80 3.15"
136 5.35"
90 3.54"
395 15.55"
10 0.39"
136 5.35"
252 9.92"
425 16.73"
10 0.39"
30 1.18"
13 0.51"
AF1350 and AF1650-30-11
+ E1250DU electronic O/L relay
17 0.67"
27 1.06"
40 1.57"
441 17.36"
66.5 2.62"
879 34.61"
AF1350, AF1650, AF2050, AF2650-30-11
+ VM 1650H mechanical interlock unit
136
5.35"
305 12.01"
72.5 2.85"
AF1350, AF1650, AF2050
136
5.35"
25 0.98"
263.5 10.37"
AF2650
136
5.35"
1SFC101123C0201 - Rev. B
312 12.28"
136
5.35"
10 0.39"
263.5 10.37"
M8 5/16-18 UMC
AF1350, AF1650, AF2050, AF2650
+ VM 1650H mechanical interlock unit
ABB | 5/177
Summary_5-3
5
5/178 | ABB
AF and EK 4-pole contactors
Overview 5/180
Ordering details
25 to 125 A AC-1
AF09 … AF38
AC / DC operated
5/182
AF09Z … AF38Z
AC / DC operated - low consumption
5/183
AF40 … AF80
AC / DC operated
5/184
Main accessories
5/186
160 to 525 A AC-1
AF116 … AF140
AC / DC operated
AF190 … AF370
AC / DC operated
5/188
5/189
Main accessories
5/190
AF116 … AF140
AC / DC operated - with 1 N.O. + 1 N.C.
5/192
AF190 … AF370
AC / DC operated - with 1 N.O. + 1 N.C.
5/193
Main accessories
5/194
AF116 … AF140
AC / DC operated - with 2 N.O. + 2 N.C.
5/196
AF190 … AF370
AC / DC operated - with 2 N.O. + 2 N.C.
Main accessories
5
5/197
5/198
800 to 1000 A AC-1
EK550, EK1000
AC operated - with 1 N.O. + 1 N.C.
EK550, EK1000
DC operated - with 2 N.O. + 1 N.C.
5/201
EK550, EK1000
AC operated - with 2 N.O. + 2 N.C.
5/202
5/200
5/204
Technical data
5/206
Terminal marking and positionning
5/216
Main dimensions
5/220
Voltage code table
5/392
Summary_5-3
Main accessories
ABB | 5/179
4-pole contactors
IEC
UL/CSA
5
A
A
25
30
45
55
70
100
125
25
30
45
55
—
—
—
AC / DC Control supply
Type
AF09
AF16
AF26
AF38
AF40
AF52
AF80
AC Control supply
Type
AF09
AF16
AF26
AF38
AF40
AF52
AF80
DC Control supply
Type
AF09
AF16
AF26
AF38
AF40
AF52
AF80
θ ≤ 40 °C
A
25
30
45
55
70
100
125
θ ≤ 60 °C (1)
A
25
30
40
45
60
80
105
θ ≤ 70 °C
A
22
26
32
37
50
70
90
With conductor cross sectional area
mm 2
4
6
10
16
35
35
50
Rated operational voltage Ue max.
V
690
690
690
690
690
690
690
A
25
30
45
55
—
—
—
IEC
UL/CSA
AC-1 Rated operational current
θ ≤ 40 °C, 690 V
General use rating
600 V
AC-1 Rated operational current
600 V
General use rating
(1) θ ≤ 55 °C for EK550, EK1000 contactors
Main accessories
Front mounting
CA4-10 (1 x N.O.), CA4-01 (1 x N.C.)
Side mounting
CAL4-11 (1 x N.O. + 1 x N.C.)
Timers
Electronic
TEF4-ON
TEF4-OFF
Interlocking units
Mechanical
VM4
Mechanical / Electrical
VEM4
Varistor + RC (AC / DC)
Built-in surge protection
Auxiliary contact blocks
Surge suppressors
5/180 | ABB
VM96-4
160
200
275
350
400
500
525
800
1000
—
—
—
—
—
—
—
540
—
AF116
AF140
AF190
AF205
AF265
AF305
AF370
—
—
AF116
AF140
AF190
AF205
AF265
AF305
AF370
EK550
EK1000
AF116
AF140
AF190
AF205
AF265
AF305
AF370
EK550
EK1000
160
200
250
275
350
375
400
800
1000
145
175
225
250
300
325
350
650
800
130
160
185
200
240
260
290
575
720
70
95
150
240
240
300
2 x 185
2 x 240
2 x 300
690
690
1000
1000
1000
1000
1000
1000
1000
—
—
—
—
—
—
—
540
—
CAL19-11 (1 x N.O. + 1 x N.C.)
CAL16-11 (1 x N.O. + 1 x N.C.)
VM19 (for same size contactors)
VH800
5
1SBC101569S0201 - Rev. C
RC-EH800
ABB | 5/181
AF09 ... AF38 4-pole contactors
25 to 55 A AC-1
AC / DC operated
Description
1SBC101095F0014
AF09 ... AF38 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e.
resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These
contactors are of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
AF09-40-00
Ordering details
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
1SBC101097F0014
5
AF26-40-00
UL/CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. … Uc max.
A
V 50/60 Hz
V DC
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF09-40-00-41
AF09-40-00-12
AF09-40-00-13
AF09-40-00-14
AF16-40-00-41
AF16-40-00-12
AF16-40-00-13
AF16-40-00-14
AF26-40-00-41
AF26-40-00-12
AF26-40-00-13
AF26-40-00-14
AF38-40-00-41
AF38-40-00-12
AF38-40-00-13
AF38-40-00-14
1SBL137201R4100
1SBL137201R1200
1SBL137201R1300
1SBL137201R1400
1SBL177201R4100
1SBL177201R1200
1SBL177201R1300
1SBL177201R1400
1SBL237201R4100
1SBL237201R1200
1SBL237201R1300
1SBL237201R1400
1SBL297201R4100
1SBL297201R1200
1SBL297201R1300
1SBL297201R1400
0.270
0.270
0.270
0.310
0.270
0.270
0.270
0.310
0.360
0.360
0.360
0.400
0.360
0.360
0.360
0.400
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF09-22-00-41
AF09-22-00-12
AF09-22-00-13
AF09-22-00-14
AF16-22-00-41
AF16-22-00-12
AF16-22-00-13
AF16-22-00-14
AF26-22-00-41
AF26-22-00-12
AF26-22-00-13
AF26-22-00-14
AF38-22-00-41
AF38-22-00-12
AF38-22-00-13
AF38-22-00-14
1SBL137501R4100
1SBL137501R1200
1SBL137501R1300
1SBL137501R1400
1SBL177501R4100
1SBL177501R1200
1SBL177501R1300
1SBL177501R1400
1SBL237501R4100
1SBL237501R1200
1SBL237501R1300
1SBL237501R1400
1SBL297501R4100
1SBL297501R1200
1SBL297501R1300
1SBL297501R1400
0.270
0.270
0.270
0.310
0.270
0.270
0.270
0.310
0.360
0.360
0.360
0.400
0.360
0.360
0.360
0.400
4 N.O. main poles
25
25
30
30
45
45
55
55
2 N.O. + 2 N.C. main poles
25
25
30
30
45
45
55
55
Auxiliary Type
contacts
fitted
Order code
Weight
Pkg
(1 pce)
kg
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use AF..-..-..-11 (see voltage code table).
AF..-..-..-11 not suitable for direct control by PLC-output.
mm, inches
10 0.39"
5 0.20"
AF09, AF16
5/182 | ABB
5.5 0.22"
AF26, AF38
2x
M4 8-32 UNC
5 0.20"
1SBC101375S0201 - Rev. A
10 0.39"
35 1.38"
ø 4.2 0.17"
70 2.76"
6 0.24"
80 3.15"
60 2.36"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
5.5 0.22"
101 3.98"
95 3.74"
2x
5.5 0.22"
M4 8-32 UNC
5 0.20"
35 1.38"
45 1.77"
ø 4.2 0.17"
71 2.80"
5.5 0.22"
60 2.36"
77 3.03"
45 1.77"
70 2.76"
35 mm EN/IEC 60715
5 0.20"
Main dimensions
AF09Z ... AF38Z 4-pole contactors
25 to 55 A AC-1
AC / DC operated - low consumption
Description
1SBC101095F0014
AF09Z ... AF38Z 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These
contactors are of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and
12...250 V DC
-- can manage large control voltage variations
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
AF09Z-40-00
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
UL/CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. … Uc max.
A
V 50/60 Hz V DC
4 N.O. main poles
25
25
AF26Z-40-00
30
30
45
45
55
55
2 N.O. + 2 N.C. main poles
25
25
30
30
45
45
55
55
Auxiliary Type
contacts
fitted
Order code
5
Weight
Pkg
(1 pce)
kg
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-40-00-20
AF09Z-40-00-21
AF09Z-40-00-22
AF09Z-40-00-23
AF16Z-40-00-20
AF16Z-40-00-21
AF16Z-40-00-22
AF16Z-40-00-23
AF26Z-40-00-20
AF26Z-40-00-21
AF26Z-40-00-22
AF26Z-40-00-23
AF38Z-40-00-20
AF38Z-40-00-21
AF38Z-40-00-22
AF38Z-40-00-23
1SBL136201R2000
1SBL136201R2100
1SBL136201R2200
1SBL136201R2300
1SBL176201R2000
1SBL176201R2100
1SBL176201R2200
1SBL176201R2300
1SBL236201R2000
1SBL236201R2100
1SBL236201R2200
1SBL236201R2300
1SBL296201R2000
1SBL296201R2100
1SBL296201R2200
1SBL296201R2300
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.400
0.400
0.400
0.400
0.400
0.400
0.400
0.400
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF09Z-22-00-20
AF09Z-22-00-21
AF09Z-22-00-22
AF09Z-22-00-23
AF16Z-22-00-20
AF16Z-22-00-21
AF16Z-22-00-22
AF16Z-22-00-23
AF26Z-22-00-20
AF26Z-22-00-21
AF26Z-22-00-22
AF26Z-22-00-23
AF38Z-22-00-20
AF38Z-22-00-21
AF38Z-22-00-22
AF38Z-22-00-23
1SBL136501R2000
1SBL136501R2100
1SBL136501R2200
1SBL136501R2300
1SBL176501R2000
1SBL176501R2100
1SBL176501R2200
1SBL176501R2300
1SBL236501R2000
1SBL236501R2100
1SBL236501R2200
1SBL236501R2300
1SBL296501R2000
1SBL296501R2100
1SBL296501R2200
1SBL296501R2300
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.400
0.400
0.400
0.400
0.400
0.400
0.400
0.400
Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the
coil terminals: A1+ for the positive pole and A2- for the negative pole.
mm, inches
10 0.39"
5 0.20"
AF09Z, AF16Z
5.5 0.22"
2x
M4 8-32 UNC
5 0.20"
AF26Z, AF38Z
ABB | 5/183
1SBC101376S0201 - Rev. A
10 0.39"
35 1.38"
ø 4.2 0.17"
70 2.76"
6 0.24"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
5.5 0.22"
101 3.98"
95 3.74"
2x
5.5 0.22"
M4 8-32 UNC
5 0.20"
35 1.38"
45 1.77"
ø 4.2 0.17"
71 2.80"
5.5 0.22"
60 2.36"
77 3.03"
45 1.77"
70 2.76"
35 mm EN/IEC 60715
5 0.20"
Main dimensions
60 2.36"
1SBC101097F0014
Ordering details
AF40 ... AF80 4-pole contactors
70 to 125 A AC-1
AC / DC operated
Description
1SBC101045V0014
AF40 ... AF80 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e.
resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC. These
contactors are of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltages ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
AF40-40-00
Ordering details
UL/CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. … Uc max.
A
V 50/60 Hz
V DC
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
20...60 (1)
48...130
100...250
250...500
20...60 (1)
48...130
100...250
250...500
20...60 (1)
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF40-40-00-41
AF40-40-00-11
AF40-40-00-12
AF40-40-00-13
AF40-40-00-14
AF52-40-00-41
AF52-40-00-11
AF52-40-00-12
AF52-40-00-13
AF52-40-00-14
AF80-40-00-41
AF80-40-00-11
AF80-40-00-12
AF80-40-00-13
AF80-40-00-14
1SBL347201R4100
1SBL347201R1100
1SBL347201R1200
1SBL347201R1300
1SBL347201R1400
1SBL367201R4100
1SBL367201R1100
1SBL367201R1200
1SBL367201R1300
1SBL367201R1400
1SBL397201R4100
1SBL397201R1100
1SBL397201R1200
1SBL397201R1300
1SBL397201R1400
1.210
1.210
1.210
1.160
1.160
1.210
1.210
1.210
1.160
1.160
1.490
1.490
1.490
1.440
1.440
24...60
24...60
48...130
100...250
250...500
24...60
24...60
48...130
100...250
250...500
20...60 (1)
48...130
100...250
250...500
20...60 (1)
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF40-22-00-41
AF40-22-00-11
AF40-22-00-12
AF40-22-00-13
AF40-22-00-14
AF80-22-00-41
AF80-22-00-11
AF80-22-00-12
AF80-22-00-13
AF80-22-00-14
1SBL347501R4100
1SBL347501R1100
1SBL347501R1200
1SBL347501R1300
1SBL347501R1400
1SBL397501R4100
1SBL397501R1100
1SBL397501R1200
1SBL397501R1300
1SBL397501R1400
1.210
1.210
1.210
1.160
1.160
1.490
1.490
1.490
1.440
1.440
125
-
n
io
2 N.O. + 2 N.C. Main Poles
70
-
at
-
ar
125
ep
-
kg
pr
100
Weight
Pkg
(1 pce)
er
AF80-40-00
Order code
nd
4 N.O. Main Poles
70
-
Auxiliary Type
contacts (1)
fitted
U
1SBC101048V0014
5
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
(1) AF..-..-..-11 not suitable for direct control by PLC-output.
mm, inches
113.5 4.47"
70 2.76"
6 0.24"
5.5 0.22"
5/184 | ABB
5.5 0.22"
10 0.39"
AF80
1SBC101987S0201
119.5 4.70"
35 x 15 mm EN/IEC 60715
119.5 4.70"
6 0.24"
7 0.28"
10 0.39"
AF40, AF52
116 4.57"
90 3.54"
7 0.28"
35 x 15 mm EN/IEC 60715
Main dimensions
N3
5
ABB | 5/185
AF09 ... AF80 4-pole contactors
Main accessories
Contactor and main accessories (other accessories available)
VEM4 mechanical and electrical interlock set including:
– VM4 mechanical interlock unit with 2 fixing clips
– VE4 electrical interlock block with A2-A2 connection
AF contactor
(without top mounted
coil terminal block)
AF contactor
Fixing clips
CAT4-11
2-pole auxiliary contact
and A1/A2 coil terminal block
AF contactor
BX4-CA
Protective cover
5
TEF4
Electronic timer
A2
VM4
BX4-CA
Protective cover
CA4
4-pole auxiliary
contact block
CAL4-11
2-pole auxiliary
contact block
BX4
Protective cover
A2
BX4-CA
Protective cover
CA4, CC4
1-pole auxiliary
contact block
CA4, CC4
1-pole auxiliary
contact block
CAL4-11
2-pole auxiliary
contact block
CA4, CC4
1-pole auxiliary
contact block
VE4
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Built-in
Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
Main
poles
Electrical and
mechanical interlock set
(between 2 contactors)
Left side
TEF4
VEM4
2-pole CAL4-11
1-pole CA4
1-pole CC4
2-pole CAT4-11
4-pole CA4
Side-mounted accessories
Auxiliary contact blocks
Electronic
timer
Right side
Max. add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5
4
0
0
0
AF26 ... AF38
4
0
0
0
AF40 ... AF52
AF80
4
4
0
0
0
0
0
0
AF09 ... AF16
AF26 ... AF38
2
2
2
2
0
0
0
0
AF40
2
2
2
2
2
2
0
0
0
0
0
0
AF80
5/186 | ABB
4 max.
2 max.
3 max.
Max. add-on
4 max.
2 max.
3 max.
Max. add-on
4 max.
4 max.
Max. add-on
4 max.
2 max.
Max. add-on
4 max.
4 max.
4 max.
or 1
or 1
–
N.C. auxiliary
or 1
or 1
–
N.C. auxiliary
or 1
–
N.C. auxiliary
or 1
or 1
N.C. auxiliary
or 1
–
–
or 1
–
–
contacts: 3 N.C.
or 1
–
–
contacts: 6 N.C.
or 1
or 1
contacts: 3 N.C.
or 1
–
contacts: 2 N.C.
or 1
or 1
or 1
max.
max.
max.
max.
or 1
or 1
–
on positions
or 1
or 1
–
on positions
or 1
or 1
on positions
or 1
or 1
on positions
or 1
or 1
or 1
1,
1,
1,
1,
–
+ 1
–
+ 1
+ 1
+ 1
2, 3, 4 and 2 N.C. max. on positions 1 ±30°, 5
–
+ 1
–
+ 1
+ 1
+ 1
1 ±30°, 2, 3, 4, 5
–
+ 1
–
+ 1
2, 3, 4 and 2 N.C. max. on positions 1 ±30°, 5
–
+ 1
–
+ 1
1 ±30°, 2, 3, 4, 5
–
+ 1
–
+ 1
–
+ 1
–
+ 1
or 1
–
+ 1
or 1
+ 1
+ 1
–
+ 1
–
+ 1
+ 1
1SBC101392S0201 - Rev. B
AF09 ... AF16
AF09 ... AF80 4-pole contactors
Main accessories
Ordering details (1)
1SBC101112F0014
1SBC101108F0014
For contactors
CA4-10
1SBC101120F0014
1SBC101114F0014
CA4-22E
1SBC101130F0014
Order code
Front-mounted instantaneous auxiliary contact blocks
AF09 ... AF80-40-00
1 0
– –
CA4-10
AF09 ... AF80-22-00
1 0
– –
CA4-10-T
0 1
– –
CA4-01
0 1
– –
CA4-01-T
2 2
– –
CA4-22E
3 1
– –
CA4-31E
4 0
– –
CA4-40E
AF09 ... AF16..-40-00
0 4
– –
CA4-04E
AF40 ... AF80-40-00
1SBN010110R1010
1SBN010110T1010
1SBN010110R1001
1SBN010110T1001
1SBN010140R1022
1SBN010140R1031
1SBN010140R1040
1SBN010140R1004
VEM4
Pkg
qty
Weight
(1 pce)
1
10
1
10
1
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
5
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
AF09 ... AF80-40-00
– –
1 0
CC4-10
1SBN010111R1010
1
AF09 ... AF80-22-00
– –
0 1
CC4-01
1SBN010111R1001
1
0.014
0.014
Side-mounted instantaneous auxiliary contact blocks
AF09 ... AF80-40-00
1 1
– –
CAL4-11
AF09 ... AF80-22-00
1 1
– –
CAL4-11-T
1
10
0.040
0.040
1
0.040
1SBN030105T1000
1SBN033405T1000
10
10
0.005
0.006
1SBN030111R1000
1
0.035
1SBN010120R1011
1SBN010120T1011
Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks
AF09 ... AF52..-40-00
1 1
– –
CAT4-11E
1SBN010151R1011
AF09 ... AF40..-22-00
1SBC101129F0014
1SBC101128F0014
Type
kg
CAL4-11
CAT4-11E
Auxiliary contacts
Note: CAT4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC.
Mechanical interlock unit
AF09 ... AF38..-40-00
AF40 ... AF80..-40-00
VM4
VM96-4
Note: VM4 includes 2 fixing clips (BB4) to maintain together both contactors.
01 NC
01NC
Mechanical and electrical interlock set
AF09, AF16..-40-00
0 2
AF26, AF38..-40-00
KM2
A2
VEM4
Note: – VEM4 includes a VM4 mechanical interlock unit with 2 fixing clips (BB4), a VE4 electrical interlock block. VE4 block must
be used with A2-A2 connection to respect the electrical connection diagram.
– VEM4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC.
1SBC101392F0014
For contactors
TEF4-ON
VEM4
Time delay
range
Delay
type
Auxiliary Type
contacts
Order code
Pkg
qty
selected by
switch
Electronic timers
AF09 ... AF80
0.1...1 s
1...10 s
10...100 s
Weight
(1 pce)
kg
ON-delay
1 1
TEF4-ON
1SBN020112R1000
1
0.065
OFF-delay
1 1
TEF4-OFF
1SBN020114R1000
1
0.065
Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.
(1) For more information, refer to main catalog "Accessories" section.
1SBC101393S0201 - Rev. B
KM1
A2
– –
ABB | 5/187
AF116 … AF140 4-pole contactors
160 to 200 A AC-1
AC / DC operated
Description
1SFC101158V0001
AF116 ... AF140 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC. These contactors are
of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF140-40-00
Ordering details
5
1SFC101193V0001
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
AF140-40-00B
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. ... Uc max.
A
V 50/60 Hz
Auxiliary Type
contacts (1)
fitted
Order code
Weight
Pkg
(1 pce)
V DC
kg
4 N.O. main poles
For connection with built-in cable clamps
160
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
200
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
With bar connections
160
-
200
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
-
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF116-40-00-11
AF116-40-00-12
AF116-40-00-13
AF116-40-00-14
AF140-40-00-11
AF140-40-00-12
AF140-40-00-13
AF140-40-00-14
1SFL427101R1100
1SFL427101R1200
1SFL427101R1300
1SFL427101R1400
1SFL447101R1100
1SFL447101R1200
1SFL447101R1300
1SFL447101R1400
2.250
2.250
2.250
2.250
2.250
2.250
2.250
2.250
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF116-40-00B-11
AF116-40-00B-12
AF116-40-00B-13
AF116-40-00B-14
AF140-40-00B-11
AF140-40-00B-12
AF140-40-00B-13
AF140-40-00B-14
1SFL427102R1100
1SFL427102R1200
1SFL427102R1300
1SFL427102R1400
1SFL447102R1100
1SFL447102R1200
1SFL447102R1300
1SFL447102R1400
2.150
2.150
2.150
2.150
2.150
2.150
2.150
2.150
(1) For other auxiliary contacts arrangements, please contact your ABB local organization.
mm, inches
5/188 | ABB
120 4.72" 120 4.72"
30 1.18" 30 1.18"
AF116, AF140-40-00B
55.5 2.18"
19.5 0.77"
128 5.04" 128 5.04"
55.5 2.18"
150 5.91"
19.5 4.96"
55.5 0.22"
SECTION A-A
SECTION A-A
A
1SFC101197C0201
AF116, AF140-40-00
19.5 4.96"
55.5 0.22"
150 5.91"
150 5.91"
30 1.18" 30 1.18"
A
128 5.04"128 5.04"
120 4.72"120 4.72"
19.5 0.77"
SECTION SECTION
A-A
A-A
A
150 5.91"
Main dimensions
A
AF190 … AF370 4-pole contactors
275 to 525 A AC-1
AC / DC operated
Description
1SFC101160V0001
AF190 ... AF370 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC. These contactors
are of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-40-00
Ordering details
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. ... Uc max.
A
V 50/60 Hz
V DC
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
4 N.O. main poles
275
-
350
-
400
-
500
-
525
-
AF370-40-00
Auxiliary Type
contacts (1)
fitted
Order code
5
Weight
Pkg
(1 pce)
kg
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
AF190-40-00-11
AF190-40-00-12
AF190-40-00-13
AF190-40-00-14
AF205-40-00-11
AF205-40-00-12
AF205-40-00-13
AF205-40-00-14
AF265-40-00-11
AF265-40-00-12
AF265-40-00-13
AF265-40-00-14
AF305-40-00-11
AF305-40-00-12
AF305-40-00-13
AF305-40-00-14
AF370-40-00-11
AF370-40-00-12
AF370-40-00-13
AF370-40-00-14
1SFL487102R1100
1SFL487102R1200
1SFL487102R1300
1SFL487102R1400
1SFL527102R1100
1SFL527102R1200
1SFL527102R1300
1SFL527102R1400
1SFL547102R1100
1SFL547102R1200
1SFL547102R1300
1SFL547102R1400
1SFL587102R1100
1SFL587102R1200
1SFL587102R1300
1SFL587102R1400
1SFL607102R1100
1SFL607102R1200
1SFL607102R1300
1SFL607102R1400
3.900
3.900
3.900
3.900
3.900
3.900
3.900
3.900
6.360
6.360
6.360
6.360
6.360
6.360
6.360
6.360
6.360
6.360
6.360
6.360
(1) For other auxiliary contacts arrangements, please contact your ABB local organization.
Main dimensions
mm, inches
A
183.75 7.23"
19.5 0.77"
SECTION A-A
180 7.09"
35.5 1.40"
ø 10.5 0.41"
5 0.20"
152.5 6.00"
A
5 0.20"
35 1.38"
AF190, AF205
1SFC101198C0201
196 7.72"
225 8.86"
33.4 1.31"
35.5 1.40"
94.7 3.73"
ø 8.5 0.33"
83.5 3.29"
140 5.51"
29.5 1.16"
1SFC101197V0001
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
43.75 1.72"
AF265, AF305, AF370
ABB | 5/189
AF116 ... AF370 4-pole contactors
Main accessories
Main accessories
(other accessories available)
CAL19-11
2-pole auxiliary
contact block
CAL19-11B
2-pole auxiliary
contact block
VM
Mechanical
interlock
5
AF contactor
with bar connections
CAL19-11
2-pole auxiliary
contact block
LT
Terminal shroud
AF contactor
with built-in cable clamps
CAL19-11B
2-pole auxiliary
contact block
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL19-11
AF116 ... AF370
4 0
0 0
2 x CAL19-11
+
2 x CAL19-11B
AF116 ... AF370
4 0
0 0
2 x CAL19-11 (1)
+
2 x CAL19-11B (1)
(between two contactors)
–
+
VM... (2)
(2) Interlock type, according to the contactor ratings (see "Accessories").
1SFC101203C0201
(1) Total number of auxiliary contact blocks for the two contactors.
Mechanical interlock units
CAL19-11B
5/190 | ABB
AF116 ... AF370 4-pole contactors
Main accessories
Ordering details (1)
1SFC101071V0001
For contactors
1SFC101035V0001
CAL19-11
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Side-mounted instantaneous auxiliary contact blocks
AF116 ... AF370
1
1 CAL19-11
1
1 CAL19-11B
1SFN010820R1011
1SFN010820R3311
2
2
0.050
0.050
Mechanical interlock unit
AF116 ... AF370
AF116 ... AF146 and AF190, AF205
AF190, AF205 and AF265 ... AF370
VM19
VM140/190
VM205/265
1SFN030300R1000
1SFN034403R1000
1SFN035203R1000
1
1
1
0.054
0.088
0.090
Terminal shrouds
AF116 … AF140, with compression lugs
AF190 … AF205, with cable clamps
AF190 … AF205, with compression lugs
AF265 … AF370, with cable clamps
AF265 … AF370, with compression lugs
LT140-40L
LT205-40C
LT205-40L
LT370-40C
LT370-40L
1SFN124203R2000
1SFN124801R2000
1SFN124803R2000
1SFN125401R2000
1SFN125403R2000
2
2
2
2
2
0.090
0.060
0.290
0.040
0.370
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
5
VM19
Terminal enlargements
AF190 … AF205
AF265 … AF370
Dimensions
hole Ø
mm
bar
mm
10.5
10.5
20 x 5
25 x 5
kg
LW205-40
LW370-40
1SFN074807R2000
1SFN075407R2000
1
1
0.306
0.540
1SFC101204C0201
(1) For more information, refer to "Accessories" section.
ABB | 5/191
AF116 … AF140 4-pole contactors
160 to 200 A AC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
1SFC101154V0001
Description
AF140-40-11
AF116 ... AF140 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC. These contactors are
of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
1SFC101192V0001
5
AF140-40-11B
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. ... Uc max.
A
V 50/60 Hz
Auxiliary Type
contacts (1)
fitted
Order code
Weight
Pkg
(1 pce)
V DC
kg
4 N.O. main poles
For connection with built-in cable clamps
160
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
200
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
With bar connections
160
-
200
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
-
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AF116-40-11-11
AF116-40-11-12
AF116-40-11-13
AF116-40-11-14
AF140-40-11-11
AF140-40-11-12
AF140-40-11-13
AF140-40-11-14
1SFL427101R1111
1SFL427101R1211
1SFL427101R1311
1SFL427101R1411
1SFL447101R1111
1SFL447101R1211
1SFL447101R1311
1SFL447101R1411
2.270
2.270
2.270
2.270
2.270
2.270
2.270
2.270
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AF116-40-11B-11
AF116-40-11B-12
AF116-40-11B-13
AF116-40-11B-14
AF140-40-11B-11
AF140-40-11B-12
AF140-40-11B-13
AF140-40-11B-14
1SFL427102R1111
1SFL427102R1211
1SFL427102R1311
1SFL427102R1411
1SFL447102R1111
1SFL447102R1211
1SFL447102R1311
1SFL447102R1411
2.170
2.170
2.170
2.170
2.170
2.170
2.170
2.170
(1) For other auxiliary contacts arrangements, please contact your ABB local organization.
5/192 | ABB
120 4.72"
120 4.72"
30 1.18"
30 1.18"
AF116, AF140-40-11B
19.5 0.77"
128 5.04"
128 5.04"
55.5 2.18"
150 5.91"
55.5 0.22"
SECTION
SECTION
A-A A-A
A
1SFC101199C0201
AF116, AF140-40-11
19.5 4.96"
150 5.91"
150 5.91"
30 1.18"
30 1.18"
A
10 0.39"
10 0.39"
150 5.91"
128 5.04"
128 5.04"
19.5 0.77"
SECTION
SECTION
A-A A-A
120 4.72"
120 4.72"
55.5 0.22"
10 0.39"
10 0.39"
mm, inches
A
19.5 4.96"
A
55.5 2.18"
Main dimensions
AF190 … AF370 4-pole contactors
275 to 525 A AC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
Description
1SFC101155V0001
AF190 ... AF370 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC. These contactors
are of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-40-11
Ordering details
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. ... Uc max.
A
V 50/60 Hz
V DC
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
4 N.O. main poles
275
-
350
-
400
-
500
-
525
-
AF370-40-11
Auxiliary Type
contacts (1)
fitted
Order code
5
Weight
Pkg
(1 pce)
kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AF190-40-11-11
AF190-40-11-12
AF190-40-11-13
AF190-40-11-14
AF205-40-11-11
AF205-40-11-12
AF205-40-11-13
AF205-40-11-14
AF265-40-11-11
AF265-40-11-12
AF265-40-11-13
AF265-40-11-14
AF305-40-11-11
AF305-40-11-12
AF305-40-11-13
AF305-40-11-14
AF370-40-11-11
AF370-40-11-12
AF370-40-11-13
AF370-40-11-14
1SFL487102R1111
1SFL487102R1211
1SFL487102R1311
1SFL487102R1411
1SFL527102R1111
1SFL527102R1211
1SFL527102R1311
1SFL527102R1411
1SFL547102R1111
1SFL547102R1211
1SFL547102R1311
1SFL547102R1411
1SFL587102R1111
1SFL587102R1211
1SFL587102R1311
1SFL587102R1411
1SFL607102R1111
1SFL607102R1211
1SFL607102R1311
1SFL607102R1411
3.920
3.920
3.920
3.920
3.920
3.920
3.920
3.920
6.380
6.380
6.380
6.380
6.380
6.380
6.380
6.380
6.380
6.380
6.380
6.380
(1) For other auxiliary contacts arrangements, please contact your ABB local organization.
Main dimensions
mm, inches
A
183.75 7.23"
10 0.39"
19.5 0.77"
SECTION A-A
180 7.09"
35.5 1.40"
ø 10.5 0.41"
5 0.20"
152.5 6.00"
A
5 0.20"
35 1.38"
AF190, AF205
1SFC101200C0201
196 7.72"
225 8.86"
33.4 1.31"
35.5 1.40"
83.5 3.29"
ø 8.5 0.33"
94.7 3.73"
140 5.51"
10 0.39"
29.5 1.16"
1SFC101195V0001
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
43.75 1.72"
AF265, AF305, AF370
ABB | 5/193
AF116 ... AF370 4-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
Main accessories
Main accessories
(other accessories available)
CAL19-11B
2-pole auxiliary
contact block
5
VM
Mechanical
interlock
AF contactor
with bar connections
CAL19-11B
2-pole auxiliary
contact block
LT
Terminal shroud
AF contactor
with built-in cable clamps
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL19-11
AF116 ... AF370
4 0
1 1
1 x CAL19-11
+
2 x CAL19-11B
AF116 ... AF370
4 0
1 1
–
+
2 x CAL19-11B (1)
(between two contactors)
–
+
VM... (2)
(2) Interlock type, according to the contactor ratings (see "Accessories").
1SFC101205C0201
(1) Total number of auxiliary contact blocks for the two contactors.
Mechanical interlock units
CAL19-11B
5/194 | ABB
AF116 ... AF370 4-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
Main accessories
Ordering details (1)
1SFC101071V0001
For contactors
1SFC101035V0001
CAL19-11
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Side-mounted instantaneous auxiliary contact blocks
AF116 ... AF370
1
1 CAL19-11
1
1 CAL19-11B
1SFN010820R1011
1SFN010820R3311
2
2
0.050
0.050
Mechanical interlock unit
AF116 ... AF370
AF116 ... AF146 and AF190, AF205
AF190, AF205 and AF265 ... AF370
VM19
VM140/190
VM205/265
1SFN030300R1000
1SFN034403R1000
1SFN035203R1000
1
1
1
0.054
0.088
0.090
Terminal shrouds
AF116 … AF140, with compression lugs
AF190 … AF205, with cable clamps
AF190 … AF205, with compression lugs
AF265 … AF370, with cable clamps
AF265 … AF370, with compression lugs
LT140-40L
LT205-40C
LT205-40L
LT370-40C
LT370-40L
1SFN124203R2000
1SFN124801R2000
1SFN124803R2000
1SFN125401R2000
1SFN125403R2000
2
2
2
2
2
0.090
0.060
0.290
0.040
0.370
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
5
VM19
Terminal enlargements
AF190 … AF205
AF265 … AF370
Dimensions
hole Ø
mm
bar
mm
10.5
10.5
20 x 5
25 x 5
kg
LW205-40
LW370-40
1SFN074807R2000
1SFN075407R2000
1
1
0.306
0.540
1SFC101206C0201
(1) For more information, refer to "Accessories" section.
ABB | 5/195
AF116 … AF140 4-pole contactors
160 to 200 A AC-1
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
1SFC101159V0001
Description
AF140-40-22
AF116 ... AF140 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC. These contactors are
of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
1SFC101194V0001
5
AF140-40-22B
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. ... Uc max.
A
V 50/60 Hz
Auxiliary Type
contacts (1)
fitted
Order code
Weight
Pkg
(1 pce)
V DC
kg
4 N.O. main poles
For connection with built-in cable clamps
160
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
200
24...60
20...60
48...130
48...130
100...250
100...250
250...500
250...500
With bar connections
160
-
200
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
-
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AF116-40-22-11
AF116-40-22-12
AF116-40-22-13
AF116-40-22-14
AF140-40-22-11
AF140-40-22-12
AF140-40-22-13
AF140-40-22-14
1SFL427101R1122
1SFL427101R1222
1SFL427101R1322
1SFL427101R1422
1SFL447101R1122
1SFL447101R1222
1SFL447101R1322
1SFL447101R1422
2.290
2.290
2.290
2.290
2.290
2.290
2.290
2.290
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AF116-40-22B-11
AF116-40-22B-12
AF116-40-22B-13
AF116-40-22B-14
AF140-40-22B-11
AF140-40-22B-12
AF140-40-22B-13
AF140-40-22B-14
1SFL427102R1122
1SFL427102R1222
1SFL427102R1322
1SFL427102R1422
1SFL447102R1122
1SFL447102R1222
1SFL447102R1322
1SFL447102R1422
2.190
2.190
2.190
2.190
2.190
2.190
2.190
2.190
(1) For other auxiliary contacts arrangements, please contact your ABB local organization.
5/196 | ABB
120 4.72"
120 4.72"
30 1.18"
30 1.18"
AF116, AF140-40-11B
19.5 0.77"
128 5.04"
128 5.04"
55.5 2.18"
150 5.91"
55.5 0.22"
SECTION
SECTION
A-A A-A
A
1SFC101201C0201
AF116, AF140-40-11
19.5 4.96"
150 5.91"
150 5.91"
30 1.18"
30 1.18"
A
10 0.39"
10 0.39"
150 5.91"
128 5.04"
128 5.04"
19.5 0.77"
SECTION
SECTION
A-A A-A
120 4.72"
120 4.72"
55.5 0.22"
10 0.39"
10 0.39"
mm, inches
A
19.5 4.96"
A
55.5 2.18"
Main dimensions
AF190 … AF370 4-pole contactors
275 to 525 A AC-1
AC / DC operated with 2 N.O. + 2 N.C. auxiliary contacts
Description
1SFC101161V0001
AF190 ... AF370 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC. These contactors
are of the block type design with 4 main poles.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
AF205-40-22
Ordering details
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc min. ... Uc max.
A
V 50/60 Hz
V DC
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
20...60
48...130
100...250
250...500
4 N.O. main poles
275
-
350
-
400
-
500
-
525
-
AF370-40-22
Auxiliary Type
contacts (1)
fitted
Order code
5
Weight
Pkg
(1 pce)
kg
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
AF190-40-22-11
AF190-40-22-12
AF190-40-22-13
AF190-40-22-14
AF205-40-22-11
AF205-40-22-12
AF205-40-22-13
AF205-40-22-14
AF265-40-22-11
AF265-40-22-12
AF265-40-22-13
AF265-40-22-14
AF305-40-22-11
AF305-40-22-12
AF305-40-22-13
AF305-40-22-14
AF370-40-22-11
AF370-40-22-12
AF370-40-22-13
AF370-40-22-14
1SFL487102R1122
1SFL487102R1222
1SFL487102R1322
1SFL487102R1422
1SFL527102R1122
1SFL527102R1222
1SFL527102R1322
1SFL527102R1422
1SFL547102R1122
1SFL547102R1222
1SFL547102R1322
1SFL547102R1422
1SFL587102R1122
1SFL587102R1222
1SFL587102R1322
1SFL587102R1422
1SFL607102R1122
1SFL607102R1222
1SFL607102R1322
1SFL607102R1422
3.940
3.940
3.940
3.940
3.940
3.940
3.940
3.940
6.400
6.400
6.400
6.400
6.400
6.400
6.400
6.400
6.400
6.400
6.400
6.400
(1) For other auxiliary contacts arrangements, please contact your ABB local organization.
Main dimensions
mm, inches
A
183.75 7.23"
10 0.39"
19.5 0.77"
SECTION A-A
180 7.09"
35.5 1.40"
ø 10.5 0.41"
5 0.20"
152.5 6.00"
A
5 0.20"
35 1.38"
AF190, AF205
1SFC101202C0201
196 7.72"
225 8.86"
33.4 1.31"
35.5 1.40"
83.5 3.29"
ø 8.5 0.33"
94.7 3.73"
140 5.51"
10 0.39"
29.5 1.16"
1SFC101196V0001
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
43.75 1.72"
AF265, AF305, AF370
ABB | 5/197
AF116 ... AF370 4-pole contactors
with 2 N.O. + 2 N.C. auxiliary contacts
Main accessories
Main accessories
(other accessories available)
CAL19-11B
2-pole auxiliary
contact block
5
CAL19-11B
2-pole auxiliary
contact block
AF contactor
with built-in cable clamps
Main accessory fitting details
Contactor
types
Main
poles
Available
auxiliary
contacts
Side-mounted accessories
Auxiliary contact blocks
CAL19-11
4 0
2 2
–
+
2 x CAL19-11B
Mechanical interlock units
(between two contactors)
–
1SFC101207C0201
AF116 ... AF370
CAL19-11B
5/198 | ABB
AF116 ... AF370 4-pole contactors
with 2 N.O. + 2 N.C. auxiliary contacts
Main accessories
Ordering details (1)
1SFC101071V0001
For contactors
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Side-mounted instantaneous auxiliary contact blocks
1
1 CAL19-11B
AF116 ... AF370
1SFN010820R3311
2
0.050
Terminal shrouds
AF116 … AF140, with compression lugs
AF190 … AF205, with cable clamps
AF190 … AF205, with compression lugs
AF265 … AF370, with cable clamps
AF265 … AF370, with compression lugs
1SFN124203R2000
1SFN124801R2000
1SFN124803R2000
1SFN125401R2000
1SFN125403R2000
2
2
2
2
2
0.090
0.060
0.290
0.040
0.370
CAL19-11
LT140-40L
LT205-40C
LT205-40L
LT370-40C
LT370-40L
5
For contactors
Terminal enlargements
AF190 … AF205
AF265 … AF370
Dimensions
Type
hole Ø
mm
bar
mm
10.5
10.5
20 x 5
25 x 5
Order code
Pkg
qty
Weight
(1 pce)
kg
LW205-40
LW370-40
1SFN074807R2000
1SFN075407R2000
1
1
0.306
0.540
1SFC101208C0201
(1) For more information, refer to "Accessories" section.
ABB | 5/199
EK550, EK1000 4-pole contactors
800 to 1000 A AC-1
AC operated - with 1 N.O. + 1 N.C. auxiliary contacts
1SFC98099-069
Description
EK550 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 600 V DC, EK1000 up to
1000 V AC.
These contactors are of the block type design with:
–– 4 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
EK1000-40-11
5
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
800
UL/CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc
(1)
A
540
1000
-
V 50 Hz
48
110
110…115
220
220…230
380
380…400
400…415
48
110
110…115
220
220…230
380
380…400
400…415
Auxiliary Type
contacts
fitted
V 60 Hz
110…120
115…127
220…240
230…255
380…415
400…440
110…120
115…127
220…240
230…255
380…415
400…440
-
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
Pkg
(1 pce)
EK550-40-11
EK550-40-11
EK550-40-11
EK550-40-11
EK550-40-11
EK550-40-11
EK550-40-11
EK550-40-11
EK1000-40-11
EK1000-40-11
EK1000-40-11
EK1000-40-11
EK1000-40-11
EK1000-40-11
EK1000-40-11
EK1000-40-11
kg
17.200
17.200
17.200
17.200
17.200
17.200
17.200
17.200
17.500
17.500
17.500
17.500
17.500
17.500
17.500
17.500
SK827041-AD
SK827041-EF
SK827041-EG
SK827041-EL
SK827041-EM
SK827041-EP
SK827041-ER
SK827041-AR
SK827044-AD
SK827044-EF
SK827044-EG
SK827044-EL
SK827044-EM
SK827044-EP
SK827044-ER
SK827044-AR
(1) Other control voltages see voltage code table.
mm, inches
11 0.43"
1)
270 10.63"
11 0.43"
1)
244 9.61"
11 0.43"1)
270 10.63"
ø 11 0.43"
225.5 8.88"
2)
139.5 5.49"
244 9.61"
23 0.91"
ø 11 0.43" 2)
(M10)
225.5 8.88"
139.5 5.49"
7/L4
2/T1
4/T2
6/T3
8/T4
1/L1
3/L2
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
223 8.78"
5/L3
6 0.24"
299 11.77"
3/L2
5)
(M10) 5)
223 8.78"
1/L1
272 10.71"
23 0.91"4)
8 0.31"
4)
12.5
0.49"
EK550
1)
2)
3)
4)
5)
5/200 | ABB
Dimension for extra auxiliary contact block.
Screw, nut and washer by-packed.
Min. distance to uninsulated wall.
Damping elements are included.
Earthing screw.
403)
1.57"
EK1000
40
1.57"
0.79"
20
67
2.64"
E1692D 11
25
0.98"
E0264D6
67
2.64"
E0263D6 11
40
3)
1.57"
E1694D
11 0.43" 1)
1SFC101217C0201
Main dimensions
EK550, EK1000 4-pole contactors
800 to 1000 A AC-1
DC operated - with 2 N.O. + 1 N.C. auxiliary contacts
1SFC98099-069
Description
EK550 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads
(i.e. resistance furnaces...) and generally for controlling power circuits up to 1000 V AC and 600 V DC,
EK1000 up to 1000 V AC.
These contactors are of the block type design with:
–– 4 main poles
–– control circuit: DC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
800
UL / CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc
A
540
1000
-
V DC
24
36
48
60
75
110
125
220
24
36
48
60
75
110
125
220
Main dimensions
Auxiliary Type
contacts
fitted
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Order code
Weight
Pkg
(1 pce)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
EK550-40-21
EK550-40-21
EK550-40-21
EK550-40-21
EK550-40-21
EK550-40-21
EK550-40-21
EK550-40-21
EK1000-40-21
EK1000-40-21
EK1000-40-21
EK1000-40-21
EK1000-40-21
EK1000-40-21
EK1000-40-21
EK1000-40-21
11 0.43"
1)
5
kg
17.200
17.200
17.200
17.200
17.200
17.200
17.200
17.200
17.500
17.500
17.500
17.500
17.500
17.500
17.500
17.500
SK827041-DB
SK827041-DC
SK827041-DD
SK827041-DT
SK827041-DG
SK827041-DE
SK827041-DU
SK827041-DF
SK827044-DB
SK827044-DC
SK827044-DD
SK827044-DT
SK827044-DG
SK827044-DE
SK827044-DU
SK827044-DF
mm, inches
296 11.65"
270 10.63"
ø 11 0.43"
270 10.63"
2)
139.5 5.49"
23 0.91"
244 9.61"
2)
(M10)
225.5 8.88"
139.5 5.49"
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
6 0.24"
1/L1
3/L2
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
223 8.78"
3/L2
8 0.31"
5)
(M10) 5)
223 8.78"
1/L1
272 10.71"
23 0.91"4)
299 11.77"
ø 11 0.43"
4)
40
3)
1)
2)
3)
4)
5)
12.5
0.49"
Dimension for extra auxiliary contact block.
Screw, nut and washer by-packed.
Min. distance to uninsulated wall.
Damping elements are included.
Earthing screw.
403)
1.57"
67
2.64"
40
1.57"
20
0.79"
EK1000
1SFC101218C0201
EK550
25
0.98"
E1693D
67
2.64"
E0264D6
1.57"
E1694D
11 0.43" 1)
225.5 8.88"
244 9.61"
296 11.65"
E0263D8
EK1000-40-21
ABB | 5/201
EK550, EK1000 4-pole Contactors
800 to 1000 A AC-1
AC Operated - with 2 N.O. + 2 N.C. auxiliary contacts
1SFC98099-069
Description
EK550 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and for controlling power circuits up to 1000 V AC and 600 V DC, EK1000 up to 1000 V AC.
These contactors are of the block type design with:
–– 4 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories
Ordering details
EK1000-40-22
5
IEC
Rated operational
current
θ ≤ 40 °C
AC-1
A
800
UL/CSA
General use
rating
600 V AC
Rated control circuit
voltage
Uc
(1)
A
540
1000
-
V 50 Hz
48
110
110…115
220
220…230
380
380…400
400…415
48
110
110…115
220
220…230
380
380…400
400…415
Auxiliary Type
contacts
fitted
V 60 Hz
110…120
115…127
220…240
230…255
380…415
400…440
110…120
115…127
220…240
230…255
380…415
400…440
-
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Order code
Weight
Pkg
(1 pce)
EK550-40-22
EK550-40-22
EK550-40-22
EK550-40-22
EK550-40-22
EK550-40-22
EK550-40-22
EK550-40-22
EK1000-40-22
EK1000-40-22
EK1000-40-22
EK1000-40-22
EK1000-40-22
EK1000-40-22
EK1000-40-22
EK1000-40-22
kg
17.200
17.200
17.200
17.200
17.200
17.200
17.200
17.200
17.500
17.500
17.500
17.500
17.500
17.500
17.500
17.500
SK827043-AD
SK827043-EF
SK827043-EG
SK827043-EL
SK827043-EM
SK827043-EP
SK827043-ER
SK827043-AR
SK827045-AD
SK827045-EF
SK827045-EG
SK827045-EL
SK827045-EM
SK827045-EP
SK827045-ER
SK827045-AR
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
11 0.43"
1)
296 11.65"
270 10.63"
244 9.61"
11 0.43"1)
ø 11 0.43"
2)
225.5 8.88"
244 9.61"
139.5 5.49"
225.5 8.88"
139.5 5.49"
4/T2
6/T3
8/T4
67
2.64"
EK550
25
0.98"
12.5
0.49"
1) Dimension for extra auxiliary contact block
2) Screw, nut and washer by-packed
3) Min. distance to uninsulated wall
4) Damping elements are included
5) Earthing screw
5/202 | ABB
3/L2
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
299 11.77"
2/T1
1/L1
403)
1.57"
223 8.78"
7/L4
40
67
2.64"
EK1000
40
1.57"
20
0.79"
E1693D
5/L3
8 0.31"
4)
6 0.24"
5)
223 8.78"
3/L2
(M10)
E0263D6 11
1/L1
272 10.71"
23 0.91"
4)
23 0.91"
5)
(M10)
E0264D6
ø 11 0.43"
2)
3)
1.57"
E1694D
270 10.63"
1SFC101219C0201
11 0.43" 1)
Notes
N4
5
ABB | 5/203
EK550, EK1000 4-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
and 2 N.O. + 1 N.C. auxiliary contacts
Main accessory fitting details
Mounting positions of the auxiliary contact
Auxiliary contact types and connecting diagrams
13
21
14
22
CAL16-11 A
31
43
32
44
CAL16-11 B
53
61
54
62
CAL16-11 C
71
83
72
84
CAL16-11 D
35
47
36
48
CCL16-11 E
(1)
(1) Contact 35-36 used for some
types of EK... contactors
EK 4-pole contactors
Contactor
types
Main
poles
Available
auxiliary
contacts
Add-on auxiliary contact
blocks
5
Mounting and positioning
Factory mounted auxiliary contacts
2-pole CAL16-11 ...
Add-on CAL16-11 auxiliary contacts
AC operated, 50 Hz, 60 Hz or 50/60 Hz
EK550, EK1000
4 0
1 1
A
+
1 x CAL16-11B
+
1 x CAL16-11C
+
1 x CAL16-11D
+
1 x CAL16-11C
CA
BD
CA
E
DC operated
EK550, EK1000
4 0
2 1
A
E
EK 4-pole reversing contactors with VH800 mechanical and electrical interlock units
"Left hand"
contactors
Interlocking
"Right hand"
contactors
Add-on auxiliary contact
blocks
Mounting and positioning
Factory mounted auxiliary contacts
2-pole CAL16-11 ...
Add-on CAL16-11 auxiliary contacts
AC operated, 50 Hz, 60 Hz or 50/60 Hz
1 x CAL16-11C
EK550, EK1000
VH800
EK550, EK1000
VH800
EK550, EK1000
+
CA
BD
1 x CAL16-11D
DC operated
–
E
E
1SFC101220C0201
EK550, EK1000
5/204 | ABB
EK550, EK1000 4-pole contactors
with 1 N.O. + 1 N.C. auxiliary contacts
and 2 N.O. + 1 N.C. auxiliary contacts
3
5
7
7
5
3
1
2
4
6
8
8
6
4
2
Ordering details (1)
A1
For contactors
A2
Auxiliary
contacts
E0747D
A2
1
Order code
Pkg
qty
Weight
(1 pce)
kg
BSS550 ... BSS1000
Side-mounted auxiliary contact blocks
EK
A078
RC-EH
Type
1
1
1
1
1
1
1
1
CAL16-11B
CAL16-11C
CAL16-11D
CCL16-11E (2)
SK829002-B
SK829002-C
SK829002-D
SK829002-E
1
1
1
1
0.050
0.050
0.050
0.050
Mechanical interlock unit for two horizontal mounted contactors
EK550, EK1000
VH800
SK829070-F
1
6.000
Connecting sets
EK550
EK1000
SK829090-E
SK829090-H
1
1
3.300
5.500
Order code
Pkg
qty
Weight
(1 pce)
SK829007-C
SK829007-C
SK829007-D
1
1
1
kg
0.015
0.015
0.015
BSS550
BSS1000
5
Surge suppressors
For contactors
EK550, EK1000
EK550, EK1000
EK550, EK1000
Rated control circuit
Type
voltage
Uc
V
AC DC
●
48...110
– RC-EH800/110
● RC-EH800/110
24...125
–
●
220...600
– RC-EH800/600
(1) See "Main accessory fitting details" table.
(2) Mounting of CCL16-11E blocks does not allow an additional second block to be added on top of it.
All DC operated EK contactors are equipped with one CCL16-11E on the right side.
1SFC101220C0201
A1
ABB | 5/205
AF09 ... AF80 4-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
AC / DC operated
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
θ ≤ 40 °C
Ie / Rated operational current AC-1
θ ≤ 60 °C
Ue max. ≤ 690 V, 50/60 Hz
M
3
3-phase motors
AF40
AF52
AF80
35 A
6 mm²
35 A
6 mm²
55 A
16 mm²
55 A
16 mm²
105 A
35 mm²
105 A
35 mm²
125 A
50 mm²
25 A
25 A
θ ≤ 70 °C 22 A
4 mm²
30 A
30 A
26 A
6 mm²
45
40
32
10
55
45
37
16
70
60
50
35
A
A
A
mm²
100 A
80 A
70 A
35 mm²
125 A
105 A
90 A
50 mm²
18 A
18 A
18 A
18 A
15 A
10.5 A
A
A
A
mm²
A
A
A
mm²
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
9A
9A
9A
9A
9.5 A
7A
23.2 A
22 A
21.2 A
20 A
17.6 A
10.5 A
23.2 A
22 A
21.2 A
20 A
17.6 A
10.5 A
40
40
40
40
35
25
A
A
A
A
A
A
53
53
53
53
45
35
A
A
A
A
A
A
80
80
80
80
65
49
A
A
A
A
A
A
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
2.2 kW
4 kW
5.5 kW
4 kW
7.5 kW
4 kW
9 kW
11 kW
4 kW
9 kW
11 kW
5.5 kW
9 kW
11 kW
5.5 kW
9 kW
9 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
5.5 kW
11 kW
11 kW
11 kW
9 kW
11 kW
18.5 kW
22 kW
22 kW
22 kW
22 kW
15
22
30
30
30
30
kW
kW
kW
kW
kW
kW
22
37
45
45
45
45
kW
kW
kW
kW
kW
kW
32 A
300 A
150 A
80 A
60 A
35 A
250 A
106 A
1.2 W
0.35 W
63 A
450 A
300 A
225 A
150 A
55 A
2.3 W
0.42 W
80 A
1000 A
600 A
350 A
250 A
110 A
950 A
600 A
600 A
300 A
3W
1W
110 A
1000 A
600 A
350 A
250 A
110 A
950 A
600 A
6.3 W
1.7 W
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection device for contactors
Without thermal overload relay - Motor protection excluded
Ue ≤ 500 V AC - gG type fuse
25 A
1 s 300 A
Rated short-time withstand current Icw
10 s 150 A
At 40 °C ambient temperature,
in free air from a cold state
30 s 80 A
1 min 60 A
15 min 35 A
at 440 V 250 A
Maximum breaking capacity N.O. main pole
cos φ = 0.45
at 690 V 106 A
at 440 V N.C. Main pole
at 690 V Ie / AC-1 0.8 W
Power dissipation per pole
Ie / AC-3 0.1 W
AC-1 600 cycles/h
Max. electrical switching frequency
50 A
450 A
300 A
225 A
150 A
55 A
1.6 W
0.42 W
160 A
1200 A
780 A
450 A
300 A
140 A
1100 A
750 A
900 A
750 A
8W
3.2 W
(1) For the corresponding kW/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor Rated Operational Powers and Currents"
(2) For the protection of motor starters against short circuits, see "Coordination with Short-circuit Protection Devices".
Main pole - Utilization characteristics according to UL / CSA
Contactor types
Standards
Max. operational voltage
UL / CSA general use rating
600 V AC
With conductor cross-sectional area
Max. electrical switching frequency
For general use
AC / DC operated
AF09
AF16
UL 508, CSA C22.2 N°14
600 V
AF26
AF38
AF40
AF52
AF80
UL 60947-4-1, CSA-C22.2 No. 60947-4-1
25 A
AWG 10
45 A
AWG 8
55 A
AWG 6
AWG 6
30 A
AWG 10
AWG 4
AWG 2
600 cycles/h
Note: 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles, see "General technical data".
1SBC101989S0201
5
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
AF09
AF16
AF26
AF38
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
5/206 | ABB
AF116 ... AF370 4-pole contactors
Technical data
Main pole - Utilization characteristics according to IEC
AC / DC operated
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
Ue max. ≤ 690 V, 50/60 Hz
With conductor cross-sectional area
AF370
EK550
EK1000
160 A
70 mm²
200 A
95 mm²
275 A
350 A
400 A
500 A
525 A
150 mm² 240 mm² 240 mm² 300 mm² 2x
(3)
(4)
185 mm² (4)
800 A
2x
240 mm²
1000 A
2x
300 mm²
160 A
145 A
130 A
70 mm²
200 A
175 A
160 A
95 mm²
275
250
200
250
225
185
150
A
A
A
A
A
A
mm²
350
300
240
275
250
200
240
(3)
A
A
A
A
A
A
mm²
400
350
290
350
300
240
240
A
A
A
A
A
A
mm²
500
400
325
375
325
260
300
(4)
A
A
A
A
A
A
mm²
525 A
425 A
350 A
400 A
350 A
290 A
2x 185 mm²
(4)
800
650
575
2x
240
mm²
1000 A
800 A
720 A
2x
300 mm²
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
116
116
116
116
-
140
140
140
140
-
190
190
190
190
-
A
A
A
A
205
205
205
205
-
A
A
A
A
265
265
265
265
-
A
A
A
A
305
305
305
305
-
A
A
A
A
370
370
370
370
-
A
A
A
A
550
550
550
550
550
550
175
A
A
A
A
A
A
A
-
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
1000 V
30 kW
37 kW
55 kW
55 kW
55 kW
75 kW
90 kW
110 kW
55 kW
75 kW
90 kW
110 kW
75 kW
90 kW
110 kW
132 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
kW
kW
kW
kW
160
280
315
315
400
500
250
kW
kW
kW
kW
kW
kW
kW
-
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
Ue max. ≤ 1000 V, 50/60 Hz
AF116
AF140 AF190
AF205
AF265
AF305
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
1000 V
50 / 60 Hz
A
A
A
5
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
A
A
A
A
A
A
A
A
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
Short-circuit protection device for contactors
Without thermal overload relay - Motor protection excluded
Ue ≤ 500 V AC - gG type fuse
200 A
250 A
1 s 1300 A
Rated short-time withstand current Icw
1460 A
10 s 928 A
At 40 °C ambient temperature,
1168 A
in free air from a cold state
30 s 536 A
674 A
1 min 379 A
477 A
15 min 160 A
200 A
at 440 V 2000 A
Maximum breaking capacity
3000 A
at 690 V cos φ = 0.45
Ie / AC-1 12 W
Power dissipation per pole
18 W
Ie / AC-3 AC-1 300 cycles/h
Max. electrical switching frequency
AC-3 300 cycles/h
AC-2, AC4 -
355 A
1900 A
1520 A
878 A
621 A
275 A
3300 A
15 W
-
400 A
2050 A
1640 A
947 A
670 A
350 A
3500 A
25 W
-
75 kW
132 kW
132 kW
160 kW
-
90 kW
160 kW
160 kW
160 kW
-
110
200
200
200
-
630 A
2650 A
2120 A
1224 A
865 A
400 A
3800 A
32 W
-
630 A
3050 A
2440 A
1409 A
996 A
500 A
4600 A
50 W
-
630 A
3700 A
2960 A
1709 A
1208 A
525 A
5000 A
72 W
-
800 A
5500 A
5300 A
3700 A
3000 A
1000 A
5400 A
5400 A
60 W
25 W
1000 A
6800 A
6400 A
4400 A
3400 A
1200 A
80 W
-
120 cycles/h -
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(3) For currents above 275 A use terminal enlargements or terminal extensions.
(4) For currents above 450 A use terminal enlargements or terminal extensions.
Main pole - Utilization characteristics according to UL / CSA
AC / DC operated
AF116
AF140
UL 60947-4-1
600 V
AF190
AF205
AF265
AF305
AF370
EK550
EK1000
UL 508, CSA C22.2 N°14
540 A
AWG 2/0 AWG 3/0 MCM 250 MCM 250 MCM 400 MCM 500 2//MCM 300 -
1SFC101209C0201
Contactor types
Standards
Max. operational voltage
UL / CSA general use rating
600 V AC
With conductor cross-sectional area
Max. electrical switching frequency
For general use
300 cycles/h
ABB | 5/207
AF09 ... AF80 4-pole contactors
Technical data
General technical data
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
B2
AF38
AF40
AF52
AF80
1000 V
8 kV
Devices complying with IEC 60947-1 /
EN 60947-1 - Environments A and B
10 millions operating cycles
3600 cycles/h
Shock direction
A
B1
B2
C1
C2
A
B1
B2
C1
C2
C1
B1
AF26
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
4 N.O.
Main poles
A
AF16
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 Environment A
Ambient air temperature close to contactor
Operation
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
A
AF09
2 N.O. + 2 N.C.
Main poles
C2
Vibration withstand
acc. to IEC 60068-2-6
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
30 g
(1)
25 g closed position / 5 g open position
(1)
15 g
(1)
25 g
(1)
25 g
(1)
30 g
(1)
25 g closed position / 5 g open position
(1)
15 g
(1)
25 g
(1)
25 g
(1)
5...300 Hz
(1)
4 g closed position / 2 g open position
(1) On request
Remark for 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles
1
R5
R3
7
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising
2 separate loads with a single supply (see diagrams below). When the contactor operates there is no mechanical overlapping
between the N.O. poles and the N.C. poles: BREAK before MAKE.
2
R6
R4
!
8
These contactors are not suitable for a reversing starter or for controlling a single load from 2 separate supplies.
Block diagrams
– Single supply and 2 separate loads
– 2 separate supplies and 2 separate loads
Main
supply
Supply
Back-up
supply
5/208 | ABB
A1
1
R3
A2
2
R4
R5
7
A1
R6
8
A2
1
R3
2
R4
R5
7
R6
8
Load
Load
Load
Load
1SBC101990S0201
5
AC / DC operated
AF116 ... EK1000 4-pole contactors
Technical data
General technical data
AC / DC operated
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
Storage
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Maximum switching frequency
AF116
AF140
AF190
AF205
AF265
AF305
AF370
1000 V
600 V
8 kV
AF contactors comply with IEC 60947-1 / EN 60947-1 - Environment A
-40 to +70 °C
-40 to +70 °C
3000 m
5 million operating cycles
300 cycles/h
5
General technical data
AC or DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation
Fitted with thermal overload relay
Without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
Closed or open position
C1
ABB
A B1
B2
C2
E1862D
A
Shock direction
A
B1
B2
C1
C2
EK550
EK1000
1000 V
600 V
8 kV
EK contactors complying with IEC 60947-1 / EN 60947-1 - Environment A
-25 to +55 °C
-40 to +70 °C
-50 to +70 °C
Category B acc. to IEC 60068-2-30
≤ 3000 m
-
5 millions operating cycles
60 cycles/h
3 millions operating cycles
1/2 sinusoidal shock for 15 ms: no change in contact position, closed or open position
10 g
10 g
10 g
10 g
10 g
1SFC101212C0201
Contactor types
ABB | 5/209
AF09 ... AF80 4-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC / DC operated
AC supply
DC supply
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Coil consumption
Average pull-in value
Average holding value
PLC-output control
Drop-out voltage
Voltage sag immunity
acc. to SEMI F47-0706
Dips withstand
-20 °C ≤ θ ≤ +60 °C
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
AF40
AF52
AF80
at θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max
At θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C (AF) 0.85 x Uc min...Uc max. - (AF..Z) 0.85 x
Uc min...1.1 x Uc max.
at θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max
24...500 V AC
(AF) 50 VA - (AF..Z) 16 VA
(AF) 2.2 VA / 2 W - (AF..Z) 1.7 VA / 1.5 W
40 VA
4 VA / 2 W
12...500 V DC
(AF) 50 W - (AF..Z) 12...16 W
(AF) 2 W - (AF..Z) 1.7 W
(AF..Z) ≥ 500 mA 24 V DC
≤ 60 % of Uc min.
20...500 V DC
40 W
2 W
≤ 60 % of Uc min.
(AF..Z) conditions of use on request
conditions of use on request
(AF..Z) 22 ms average for Uc ≥ 24 V 50/60 Hz or
Uc ≥ 20 V DC
24 ms average
40...95
38...90
11...95
13...98
(1)
(1)
(1)
(1)
ms
ms
ms
ms
(1) On request.
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AF09
AF16
Pos. 2
AF26
+30°
AF38
AF40
AF52
AF80
-30°
Pos. 4
Pos. 3
Pos. 1
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
Pos. 5
Max. add-on N.C. auxiliary contacts: see accessory fitting details for a 4-pole contactor AF09 ... AF80
The contactors can be assembled side by side
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
35 x 15 mm
2 x M4 or 2 x M6 screws
placed diagonally
1SBC101991S0201
5
Average pull-in value
Average holding value
AF09
AF16
AF26
AF38
At θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C 0.85 x Uc min...Uc max.
5/210 | ABB
AF116 ... AF370 4-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
Rated control circuit voltage Uc
Coil consumption
AC control voltage 50/60 Hz
24...60 V AC
48...130 V AC
100...250 V AC
250...500 V AC
DC control voltage
20...60 V DC
48...130 V DC
100...250 V DC
250...500 V DC
Drop-out voltage
Operating time
Coil supply between A1 - A2
Between coil energization and:
Between coil de-energization and:
AF116
AF140
AF190
AF205
At θ ≤ 70 °C 0.85 x Uc min ... 1.1 x Uc max
At θ ≤ 70 °C 0.80 x Uc min ... 1.1 x Uc max
24...500 V AC, 20...500 V DC
AF265
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
225 VA
5.5 VA
170 VA
4 VA
130 VA
6 VA
205 VA
16 VA
165 VA
6 VA
175 VA
4 VA
220 VA
7 VA
185 VA
16 VA
475 VA
8.5 VA
340 VA
17 VA
385 VA
17.5 VA
420 VA
21 VA
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
Average pull-in value
Average holding value
210 W
2.5 W
130 W
2.5 W
135 W
3W
205 W
4W
55 % of Uc min
205 W
2.5 W
130 W
2.5 W
190 W
2.5 W
190 W
4W
400 W
3.5 W
360 W
2.5 W
410 W
4.5 W
600 W
4.7 W
20...55 ms
40..70 ms
25...60 ms
45...80 ms
30...60 ms
45...80 ms
AC / DC operated
AC supply
DC supply
N.O. contact closing
N.O. contact opening
AF305
AF370
5
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
AF116
AF140
Pos. 2
AF190
+30°
AF205
AF265
AF305
AF370
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Pos. 6
Max. add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 4-pole contactor
AF116 ... AF370
The contactors can be assembled side by side
4 x M5
1SFC101210C0201
Mounting distances
Fixing
On rail acc. to IEC 60715, EN 60715
By screws (not supplied)
ABB | 5/211
EK550 ... EK1000 4-pole contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC control voltage
Rated control circuit voltage
Coil consumption
50 Hz
60 Hz
50 Hz
Average pull-in value
60 Hz
50/60 Hz (1)
50 Hz
Average holding value
60 Hz
50/60 Hz (1)
Drop-out voltage in % of Uc min.
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
EK550
EK1000
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.
Please also refer to "Mounting characteristics and conditions for use"
48...500 V
110...600 V
3500 VA
4000 VA
3800 / 3400 VA
125 VA / 50 W
140 VA / 60 W
140 VA /60 W
approx. 45...65 %
30...60
25...55
10...20
13...23
ms
ms
ms
ms
(1) "A" coil voltage: see "Coil voltage code table".
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
DC control voltage
Rated control circuit voltage
Coil consumption
Drop-out voltage
Coil time constant
Open
Closed
Operating time
Between coil energization and:
Between coil de-energization and:
DC operated
DC supply
Average pull-in value
Average holding value
L/R
L/R
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
EK550
EK1000
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.
Please also refer to "Mounting characteristics and conditions for use"
24...220 V
1100 W
20 W
approx. 15...50 % of Uc min.
12 ms
60 ms
60...80
55...75
10...35
13...38
ms
ms
ms
ms
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
EK550
EK1000
Position 2
ABB
Position 4
ABB
+30
ABB
-30
Position 5
Position 3
ABB
E1863D1
Position 6
Position 1
Position 1 30
Max. N.O. or N.C. built-in and add-on N.O. or N.C. auxiliary contacts:
see accessory fitting details for 4-pole contactor EK550, EK1000
Control voltage / Ambient temperature
Mounting
1, 1±30°, 2, 3, 4, 5
positions
6
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (supplied)
(2) Damping elements are supplied.
5/212 | ABB
at θ ≤ 70 °C
at θ ≤ 70 °C
0.85…1.1 x Uc
Unauthorized
The contactors can be assembled side by side
–
4 x M6 (2)
1SFC101211C0201
5
AC operated
AC supply
AF09 ... AF38 4-pole contactors
Technical data
Connecting characteristics
Contactor types
Main terminals
AF09
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
Bars or lugs
1x
2x
1x
2x
1x
2x
L<
AF16
AF26
AF38
AF40
AF52
AF80
Screw terminals with
cable clamp
Screw terminals with
double connector
2 x (5.5 width x 6.8
depth)
Screw terminals with
double connector
2 x (9.3 width x 7.9/10.3
depth)
Screw terminals with
double connector
2 x (12.4 width x 9.3/11.1
depth)
1...6 mm²
1...6 mm²
0.75...6 mm²
0.75...6 mm²
0.75...4 mm²
0.75...2.5 mm²
9.6 mm
1.5...16
1.5...16
1.5...16
1.5...16
1.5...16
1.5...16
-
6...35 mm²
6...35 mm²
4...35 mm²
4...35 mm²
4...35 mm²
4...35 mm²
9.2 mm
6...70 mm²
6...50 mm²
6...50 mm²
6...50 mm²
6...50 mm²
6...50 mm²
12.2 mm
AWG 16...10
10 mm
1.5 Nm / 13 lb.in
AWG 16...6
12 mm
2.5 Nm / 22 lb.in
AWG 10...2
16 mm
4 Nm / 35 lb.in
AWG 6...1
17 mm
6 Nm / 53 lb.in
mm²
mm²
mm²
mm²
mm²
mm²
5
6
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Auxiliary conductors
(coil terminals)
Rigid solid
1 or 2 x
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
Lugs
1x
2x
1x
2x
1x
2x
L<
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
6
Coil terminals
AWG 18...14
10 mm
1.2 Nm / 11 lb.in
IP20
IP10
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
M4.5
M6
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Flat Ø 6.5 / Pozidriv 2
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
M8
hexagon socket (s = 4 mm)
1SBC101988S0201
1 or 2 x
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Screw terminals
Main terminals
ABB | 5/213
AF116 ... AF370 4-pole contactors
Technical data
Connecting characteristics
AC / DC operated
AF116
AF140
AF190
8 Nm
–
–
–
1 x 10...70 mm²
LD... included (1)
8 Nm
2 x 10...70 mm²
LD... included (1)
1x
8 Nm
22 mm (.866 in)
6 mm (.236 in)
LL... included
9 Nm / 80 lb.in
1 x AWG 6…3/0
LD... included (1)
8 Nm / 71 lb.in
2 x AWG 6…3/0
LD... included (1)
8 Nm / 71 lb.in
Lugs
W≤
Ø>
Socket type
Tightening torque
Connection capacity acc. to UL / CSA
Clamp type
Tightening torque
Connection capacity acc. to UL / CSA
Clamp type
Tightening torque
Auxiliary conductors
(coil terminals)
Solid / stranded
Flexible
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
1x
2x
1x
2x
1x
2x
1x
2x
L<
l>
1 or 2 x
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Screw terminals
Main terminals
AF370
5
10
7
10...95 mm²
LD... included (1)
8 Nm
2 x 10...95 mm²
LD... included (1)
1x
Tightening torque
ø L
AF305
19.5
5
ø 6.5
Tightening torque
Al cable - Stranded
Clamp type
Tightening torque
Cu cable - Flexible
Clamp type
Tightening torque
Cu cable - Flexible
Clamp type
AF265
17.5
3
Connection capacity (min. ... max.)
Main conductors (poles)
Cu cable - Stranded
Clamp type
Tightening torque
Cu cable - Stranded
Clamp type
5
AF205
13
ø 8.5
ø 10.5
6...150 mm²
1SDA066917R1
14 Nm
50...120 mm²
1SFN074709R1000,
LZ185-2C/120
16 Nm
95...185 mm²
1SDA054988R1
31 Nm
6...120 mm²
1SDA066917R1
14 Nm
50...95 mm²
1SFN074709R1000,
LZ185-2C/120
16 Nm
24 mm (.945 in)
8 mm (.315 in)
LL... included
18 Nm / 160 lb.in
6…300 MCM
ATK185 (2)
34 Nm / 301 lb.in
–
–
–
16...300 mm²
1SDA055016R1
25 Nm
70...185 mm²
1SCA022194R0890,
OZXB4
22 Nm
185...240 mm²
1SDA055020R1
43 Nm
16...240 mm²
1SDA055016R1
25 Nm
70...185 mm²
1SCA022194R0890,
OZXB4
22 Nm
32 mm (1.260 in)
10 mm (.394 in)
LL... included
28 Nm / 248 lb.in
4…400 MCM
ATK300 (2)
42 Nm / 372 lb.in
4…500 MCM
ATK300/2 (2)
42 Nm / 372 lb.in
M8
M10
14.3
Contactor types
Main terminals
Flat type
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.5 mm
AWG 18...14
9 mm
1.00 Nm / 9 lb.in
IP00
IP20
M6
Screws and bolts
Coil terminals (delivered in open position)
M3.5
Screwdriver type Flat Ø 5.5 mm / Pozidriv 2
Screwdriver type
1SFC101213C0201
(1) LD... not included for AF116 ... AF146-30-..B.
(2) Available in North America only.
5/214 | ABB
EK550 ... EK1000 4-pole contactors
Technical data
Connecting characteristics
AC or DC operated
EK550
EK1000
40
15
8
E1864D
E1868D
4.5
ø 11
ø 6.6
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid with
connector
ø L
Cu cable
Al/Cu cable
Al/Cu cable
Bars or lugs
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Auxiliary conductors
(coil terminals)
Rigid solid
Flexible with ferrule
l L
Bars or lugs
1x
1x
2x
L≤
Ø>
1 or 2 x
70...300 mm²
70...300 mm²
35...185 mm²
55 mm
10 mm
3 x 4 - 500 MCM
18 Nm / 160 Ib.in
22 Nm
1x
2x
1x
2x
L≤
l>
1 or 2 x
0.5…2.5 mm²
0.5…2.5 mm²
0.5…2.5 mm²
0.5…2.5 mm²
8 mm
3.7 mm
18…14 AWG
1.00 Nm / 9 lb.in
1.20 Nm
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Screw terminals
Main terminals
Coil terminals (delivered in open positions)
95...300 mm²
95...300 mm²
5
-
IP00
IP20
M10
Screws and bolts
M3.5
Screwdriver type Flat Ø 5.5 mm / Pozidriv 2
1SFC101214C0201
Contactor types
Main terminals
Flat type
ABB | 5/215
AF09 ... AF80 4-pole contactors
Terminal marking and positioning
AF09 ... AF38 contactors - AC / DC operated
Standard devices without addition of auxiliary contacts
A1 A2
A1 A2
1L1 3L2 5L3 7L4
R3
1
2T1 4T2 6T3 8T4
2
R4
R5
R6
7
AF09 ... AF80..-40-00
1L1
3L2
5L3 7L4
A2
2T1
4T2
6T3 8T4
A1
1
R3
R5
7
A2
2
R4
R6
8
8
A1 A2
A1 A2
A1
AF09 ... AF40..-22-00
AF80-22-00
AF09 ... AF80..-40-00
AF09 ... AF40..-22-00
AF80-22-00
5
Other possible contact combinations with auxiliary contacts added by the user
A1 A2
A1 A2
A1 A2
A1 A2
1L1 3L2 5L3 7L4
1L1 3L2 5L3 7L4
1L1 3L2 5L3 7L4
1L1 3L2 5L3 7L4
13
1-
=
NO
14
+
1-
2T1 4T2 6T3 8T4
2T1 4T2 6T3 8T4
A1 A2
A1 A2
-3
13 21
NO
NO
-4
14 22
Combination 10 = AF09 ... AF80..-40-00 + CA4-10
1L1 3L2 5L3 7L4
NC
A1 13 21
=
+
14 22 A2
2T1 4T2 6T3 8T4
NO
2-
-3
+
2T1 4T2 6T3 8T4
2T1 4T2 6T3 8T4
A1 A2
A1 A2
NO
-1
+
NC
-4
-2
Combination 11 = AF09 ... AF80..-40-00 + CA4-10 + CA4-01
A1 A2
A1 A2
1L1 3L2 5L3 7L4
1L1 3L2 5L3 7L4
13 21 31 43
NC
NO
NC
14 22 A2
2T1 4T2 6T3 8T4
3L2
5L3 7L4
13
NO
A2
2T1
4T2
6T3 8T4
NO
14
Combination 10
A1
1L1
3L2
5L3 7L4
13 21
NO NC
A2
2T1
4T2
6T3 8T4
NO NC
14 22
Combination 11
A1
1L1
3L2
5L3 7L4
13 21
NO NC
A2
2T1
4T2
6T3 8T4
NO NC
14 22
13 21 31 43
=
+
14 22 32 44
NO
NC
NC
NO
14 22 32 44
2T1 4T2 6T3 8T4
2T1 4T2 6T3 8T4
A1 A2
A1 A2
Combination 22 = AF09 ... AF80..-40-00 + CA4-22E
Combination 11
A1
1L1
3L2
5L3 7L4
13 21
NO NC
31
NC
43
NO
A2
2T1
4T2
6T3 8T4
NO NC
14 22
NC
32
NO
44
Combination 22
A1 A2
A1 A2
1L1 3L2 5L3 7L4
1L1 3L2 5L3 7L4
NO
13X
21X
NC
=
NC
22X
14X
NC
NC
+
22X
14X
2T1 4T2 6T3 8T4
A1 A2
Combination 11 =
NO
A1
1L1
3L2
5L3 7L4
13X 21X
NO NC
A2
2T1
4T2
6T3 8T4
NO NC
14X 22X
2T1 4T2 6T3 8T4
A1 A2
CAL4-11 + AF09 ... AF80..-40-00
Combination 11
Note: Only AF09..Z ... AF38..Z contactor with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the
negative pole
5/216 | ABB
1SBC101480S0201 - Rev. A
13X
21X
NO
1-
=
NC
NO NC
Combination 11 = AF09 ... AF80..-40-00 + CAT4-11E
NO
2-
1L1
1L1 3L2 5L3 7L4
A1 13 21
NO
1-
A1
AF116 ... AF370 4-pole contactors
Terminal marking and positioning
AF116 ... AF370 contactors -
AC / DC operated
Standard devices without addition of auxiliary contacts
3L2
1L1
5L3
A1
2T1
7L4
A2
4T2
A1
1L1 3L2
5L3
7L4
A2
2T1 4T2
6T3
8T4
8T4
6T3
AF116 ... AF370-40-00
5
AF116 ... AF370-40-00
Standard devices with factory mounted auxiliary contacts
3L2
A1
NO 13X
5L3
7L4
A2
1L1
3L2
A1
NO 13X
5L3
7L4
A2
43X NO
NC 21X
31X NC
NC 22X
NC 22X
32X NC
NO 14X
NO 14X
44X NO
NC 21X
2T1
4T2
AF116 ... AF370-40-11
6T3
8T4
2T1
4T2
AF116 ... AF370-40-22
6T3
A1
1L1 3L2
5L3
7L4
A2
2T1 4T2
6T3
8T4
13X
NO
21X
NC
NO
14X
NC
22X
AF116 ... AF370-40-11
A1
1L1
3L2
5L3
7L4
13X
NO
21X
NC
31X
NC
43X
NO
A2
2T1
4T2
6T3
8T4
NO
14X
NC
22X
NC
32X
NO
44X
8T4
AF116 ... AF370-40-22
1SFC101215C0201
1L1
ABB | 5/217
EK 4-pole contactors
Terminal marking and positioning
EK550, EK1000 contactors - AC operated
Standard devices
13
1L1
3L2
5L3
7L4
13
21
22
14
1L1
3L2
5L3
7L4
21
A1
2T1
4T2
6T3
5
3
1
13
7
14
8T4
A2
EK550, EK1000-40-11
2
6
4
14
8
31
22
21
32
2T1
4T2
6T3
8T4
22
EK550, EK1000-40-11
43
EK550, EK1000-40-22
A1
1
3
5
7
13
21
31
43
A2
2
4
6
8
14
22
32
44
44
EK550, EK1000-40-22
Other possible contact combinations with auxiliary contacts added by the user
53 13
1L1
3L2
5L3
7L4
1L1
3L2
5L3
7L4
43 83
13
43
53
83
61 21
31 71
21
31
61
71
62 22
32 72
22
32
62
72
54 14
44 84
14
44
54
84
2T1
4T2
6T3
8T4
Combination 44
=
A1
1
3
5
7
13
21
31
43
53
61
71
83
A2
2
4
6
8
14
22
32
44
54
62
72
84
Combination 44
2T1
4T2
6T3
8T4
EK550, EK1000-40-22
+
A1
1
3
5
7
13
21
31
43
A2
2
4
6
8
14
22
32
44
= EK550, EK1000-40-22
CAL16-11C +
53
61
54
62
+ CAL16-11C +
CAL16-11D
71
83
72
84
CAL16-11D
EK550, EK1000 contactors - with multifrequency coil or DC operated
Standard devices
Resistor only for
EK550, EK1000
13
1L1
3L2
5L3
7L4
47
35
21
22
36
14
48
2T1
4T2
6T3
8T4
V DC
EK550, EK1000-40-21
{
R1
35
A2
A1
36
13
14
21
22
47
48
1 L1
A1
A2
5
3
1
2
7
6
4
13
8
14
47
21
48
22
EK550, EK1000-40-21
2 T1
3 L2
4 T2
5 L3
6 T3
7 L4
8 T4
EK550, EK1000 DC operated
Other possible contact combinations with auxiliary contacts added by the user
Resistor only for
EK550, EK1000
1L1
3L2
5L3
7L4
Resistor only for
EK550, EK1000
1L1
3L2
5L3
7L4
47
13
47
53
61 21
35
21
35
61
62 22
36
22
36
62
48
14
48
54
53 13
54 14
2T1
4T2
6T3
8T4
Combination 32
=
A1
1
3
5
7
13
21
47
53
61
A2
2
4
6
8
14
22
48
54
62
Combination 32
5/218 | ABB
=
2T1
4T2
6T3
8T4
EK550, EK1000-40-21
+
A1
1
3
5
7
13
21
47
A2
2
4
6
8
14
22
48
EK550, EK1000-40-21
+
CAL16-11C
53
61
54
62
CAL16-11C
1SFC101216C0201
5
Notes
N5
5
ABB | 5/219
AF09, AF16 4-pole contactors
5.5 0.22"
10 0.39"
35 1.38"
2x
ø 4.2 0.17"
M4 8-32 UNC
2x
M4 8-32 UNC
70 2.76"
ø 4.2 0.17"
5 0.20"
5.5 0.22"
35 1.38"
71 2.80"
5.5 0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
6 0.24"
80 3.15"
6 0.24"
5.5 0.22"
80 3.15"
77 3.03"
71 2.80"
5 0.20"
45 1.77"
60 2.36"
77 3.03"
45 1.77"
70 2.76"
mm, inches
60 2.36"
Main dimensions
10 0.39"
5 0.20"
AF09, AF16
5 0.20"
AF09, AF16
5
110.5 4.35"
71 2.80"
77 3.03"
10 0.39"
12 0.47"
71 2.80"
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
80 3.15"
45 1.77"
5.5 0.22"
10 0.39"
AF09, AF16
+ CA4, CC4 1-pole auxiliary contact block
AF09, AF16
+ CAL4-11 2-pole auxiliary contact block
102.5 4.04"
110.5 4.35"
71 2.80"
10 0.39"
45 1.77"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/220 | ABB
10 0.39"
5.5 0.22"
43 1.69"
5.5 0.22"
AF09, AF16
+ CAT4 2-pole auxiliary contact and coil terminal block
1SBC101485S0201 - Rev. A
AF09, AF16
+ CA4 4-pole auxiliary contact block
80 3.15"
5.5 0.22"
43 1.69"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
35 mm EN/IEC 60715
71 2.80"
45 1.77"
AF09, AF16 4-pole contactors
mm, inches
133.5 5.26"
45 1.77"
45 1.77"
2x
M4 8-32 UNC
70 2.76"
5 0.20"
5.5 0.22"
60 2.36"
5.5 0.22"
35 mm EN/IEC 60715
1.1 0.04"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
6 0.24"
35 1.38"
ø 4.2 0.17"
5.5 0.22"
5.5 0.22"
80 3.15"
77 3.03"
710.39"
2.80"
10
71 2.80"
40.5 1.59"
Main dimensions
10 0.39"
5 0.20"
AF09, AF16
+ TEF4 electronic timer
AF09, AF16
5
102.5
4.04"
102.5
4.04"
71 71
2.80"
2.80"
10 10
0.39"
0.39"
2 x2 x
M4M4
8-32
UNC
8-32
UNC
80 80
3.15"
3.15"
70 2.76"
70 2.76"
5 0.20"
5 0.20"
60 2.36"
60 2.36"
5.55.5
0.22"
0.22"
43 1.69"
43 1.69"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
91.5 3.60"
5.55.5
0.22"
0.22"
ø 4.2
0.17"
ø 4.2
0.17"
AF09..-40-00, AF16..-40-00
+ VEM4 mechanical and electrical interlock set
5 0.20"
5 0.20"
AF09..-40-00, AF16..-40-00
+ VEM4 mechanical and electrical interlock set
1SBC101485S0201 - Rev. A
90 90
3.54"
3.54"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/221
AF26, AF38 4-pole contactors
mm, inches
5.5 0.22"
ø 4.2 0.17"
5.5 0.22"
35 1.38"
2x
M4 8-32 UNCø 4.2 0.17"
10 0.39"
10 0.39"
5 0.20"
2x
M4 8-32 UNC
70 2.76"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
35 mm EN/IEC 60715
6 0.24"
35 1.38"
5.5 0.22"
5 0.20"
95 3.74"
5.5 0.22"
80 3.15"
101 3.98"
95 3.74"
70 2.76"
45 1.77"
5 0.20" 60 2.36"
101 3.98"
45 1.77"
60 2.36"
Main dimensions
5 0.20"
AF26, AF38
AF26, AF38
5
101 3.98"
134.5 5.30"
95 3.74"
45 1.77"
12 0.47"
10 0.39"
95 3.74"
45 1.77"
5.5 0.22"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
AF26, AF38
+ CAL4-11 2-pole auxiliary contact block
AF26, AF38
+ CA4, CC4 1-pole auxiliary contact block
134.5 5.30"
126.5 4.98"
10 0.39"
45 1.77"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
5/222 | ABB
80 3.15"
10 0.39"
5.5 0.22"
5.5 0.22"
AF26, AF38
+ CAT4 2-pole auxiliary contact and coil terminal block
1SBC101486S0201 - Rev. A
AF26, AF38
+ CA4 4-pole auxiliary contact block
43 1.69"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
5.5 0.22"
95 3.74"
43 1.69"
95 3.74"
35 mm EN/IEC 60715
45 1.77"
AF26, AF38 4-pole contactors
mm, inches
101 3.98"
157.5 6.20"
3.74"
10950.39"
45 1.77"
95 3.74"
45 1.77"
ø 4.2 0.17"
2x
M4 8-32 UNC
10 0.39"
AF26, AF38
+ TEF4 electronic timer
70 2.76"
5.5 0.22"
5 0.20"
35 mm EN/IEC 60715
5.5 0.22"
60 2.36"
1.1 0.04"
6 0.24"
35 mm
80 EN/IEC
3.15" 60715
6 0.24"
80 3.15"
35 1.38"
5.5 0.22"
5.5 0.22"
40.5 1.59"
Main dimensions
5 0.20"
AF26, AF38
5
126.5 4.98" 126.5 4.98"
80 3.15"
60 2.36"
ø 4.2 0.17" ø 4.2 0.17"
5 0.20"
AF26..-40-00, AF38..-40-00
+ VEM4 mechanical and electrical interlock set
5 0.20"
AF26..-40-00, AF38..-40-00
+ VEM4 mechanical and electrical interlock set
1SBC101486S0201 - Rev. A
5.5 0.22"
2x
2x
M4 8-32 UNC
M4 8-32 UNC
70 2.76"
80 3.15"
5 0.20"
10 0.39"
5 0.20"
10 0.39"
60 2.36"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
91.5 3.60"
91.5 3.60"
5.5 0.22"
95 3.74"
5.5 0.22"
70 2.76"
95 3.74"
5.5 0.22"
43 1.69"
90 3.54"
43 1.69"
90 3.54"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/223
AF40, AF52 4-pole contactors
Main dimensions
mm, inches
60 2.36"
113.5 4.47"
70 2.76"
2x
M6 ¼-20 UNC
ø 6.4 0.25"
110 4.33"
4.6 0.18"
5.5 0.22"
100 3.94"
119.5 4.70"
35 x 15 mm EN/IEC 60715
6 0.24"
7 0.28"
10 0.39"
5 0.20"
AF40, AF52
AF40, AF52
5
147 5.79"
113.5 4.47"
70 2.76"
10
12 0.47"
0.39"
113.5 4.47"
70 2.76"
7 0.28"
6 0.24"
6 0.24"
7 0.28"
5.5 0.22"
35 x 15 mm EN/IEC 60715
119.5 4.70"
43 1.69"
119.5 4.70"
35 x 15 mm EN/IEC 60715
5.5 0.22"
10 0.39"
AF40, AF52
+ CAL4-11 2-pole auxiliary contact block
AF40, AF52
+ CA4, CC4 1-pole auxiliary contact block
147 5.79"
113.5 4.47"
139 5.47"
10
70 2.76"
0.39"
7 0.28"
113.5 4.47"
10
0.39"
7 0.28"
5.5 0.22"
43 1.69"
35 x 15 mm EN/IEC 60715
6 0.24"
AF40, AF52
+ CAT4 2-pole auxiliary contact and coil terminal block
1SBC101977S0201
AF40, AF52
+ CA4 4-pole auxiliary contact block
119.5 4.70"
5.5 0.22"
43 1.69"
35 x 15 mm EN/IEC 60715
119.5 4.70"
6 0.24"
70 2.76"
5/224 | ABB
AF40, AF52 4-pole contactors
Main dimensions
mm, inches
169.7 6.68"
113.5 4.47"
70 2.76"
60 2.36"
10
0.39"
6 0.24"
7 0.28"
2x
M6 ¼-20 UNC
ø 6.4 0.25"
4.6 0.18"
110 4.33"
5.5 0.22"
100 3.94"
40.5 1.59"
119.5 4.70"
35 x 15 mm EN/IEC 60715
1.1 0.04"
5 0.20"
AF40, AF52
+ TEF4 electronic timer
AF40, AF52
5
113.5 4.47"
140 5.51"
2x
M6 ¼-20 UNC
130 5.12"
110 4.33"
4.6 0.18"
5.5 0.22"
100 3.94"
119.5 4.70"
6 0.24"
7 0.28"
10 0.39"
ø 6.4 0.25"
5 0.20"
AF40, AF52
+ VM96-4 mechanical interlock unit
1SBC101977S0201
AF40, AF52
+ VM96-4 mechanical interlock unit
ABB | 5/225
AF80 4-pole contactors
Main dimensions
mm, inches
80 3.15"
116 4.57"
90 3.54"
2x
M6 ¼-20 UNC
ø 6.4 0.25"
110 4.33"
4.6 0.18"
5.5 0.22"
100 3.94"
119.5 4.70"
35 x 15 mm EN/IEC 60715
6 0.24"
7 0.28"
10 0.39"
5 0.20"
AF80
AF80
5
149 5.87"
116 4.57"
90 3.54"
10
12 0.47"
0.39"
116 4.57"
90 3.54"
7 0.28"
6 0.24"
6 0.24"
7 0.28"
5.5 0.22"
35 x 15 mm EN/IEC 60715
119.5 4.70"
43 1.69"
119.5 4.70"
35 x 15 mm EN/IEC 60715
5.5 0.22"
10 0.39"
AF80
+ CAL4-11 2-pole auxiliary contact block
AF80
+ CA4, CC4 1-pole auxiliary contact block
149 5.87"
171.8 6.76"
10
90 3.54"
0.39"
1.1 0.04"
35 x 15 mm EN/IEC 60715
119.5 4.70"
5.5 0.22"
AF80
+ TEF4 Electronic timer
1SBC101978S0201
43 1.69"
35 x 15 mm EN/IEC 60715
119.5 4.70"
AF80
+ CA4 4-pole auxiliary contact block
5.5 0.22"
10
0.39"
7 0.28"
6 0.24"
7 0.28"
116 4.57"
40.5 1.59"
116 4.57"
6 0.24"
90 3.54"
5/226 | ABB
AF80 4-pole contactors
Main dimensions
mm, inches
116 4.57"
180 7.09"
2x
M6 ¼-20 UNC
170 6.69"
110 4.33"
4.6 0.18"
5.5 0.22"
100 3.94"
119.5 4.70"
6 0.24"
7 0.28"
AF80
+ CA4, CC4 1-pole auxiliary contact block
ø 6.4 0.25"
5 0.20"
AF80
+ VM96-4 mechanical interlock unit
5
1SBC101978S0201
10 0.39"
ABB | 5/227
AF116, AF140 4-pole contactors
Main dimensions
mm, inches
SECTION A-A
A
150 5.91"
5
19.5 4.96"
128 5.04"
55.5 0.22"
120 4.72"
60 2.36"
M4 8-32 UNC
100 3.94"
10 0.39"
30 1.18"
AF116, AF140-40-00 + CAL19 2-pole auxiliary contact block
AF116, AF140-40-11
AF116, AF140-40-..(B)
SECTION A-A
A
120 4.72"
150 5.91"
19.5 0.77"
128 5.04"
55.5 2.18"
10 0.39"
30 1.18"
1SFC101228C0201
AF116, AF140-40-00B + CAL19 2-pole auxiliary contact block
AF116, AF140-40-11B
5/228 | ABB
AF190, AF205 4-pole contactors
Main dimensions
mm, inches
SECTION A-A
70 2.76"
152.5 6.00"
A
35.5 1.40"
4X
M5 10-24 UNC
5 0.20"
196 7.72"
165 6.50"
83.5 3.29"
ø 8.5 0.33"
29.5 1.16"
140 5.51"
10 0.39"
5
35 1.38"
AF190, AF205-40
1SFC101229C0201
AF190, AF205-40-00 + CAL19 2-pole auxiliary contact block
AF190, AF205-40-11
ABB | 5/229
AF265, AF370 4-pole contactors
Main dimensions
mm, inches
A
183.75 7.23"
180 7.09"
19.5 0.77"
35.5 1.40"
5 0.20"
225 8.86"
94.7 3.73"
ø 10.5 0.41"
33.4 1.31"
10 0.39"
5
43.75 1.72"
AF265, AF370-40-00 + CAL19 2-pole auxiliary contact block
AF265, AF370-40-11
4X
M5 10-24 UNC
187 7.36"
87.5 3.44"
1SFC101230C0201
AF265, AF370-40
5/230 | ABB
EK550, EK1000 4-pole contactors
AC operated
Main dimensions
111)
0.43"
mm, inches
111)
0.43"
270 10.63"
244 9.61"
225.5 8.88"
ø 11 0.43" 2)
139.5 5.49"
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
200 7.87"
3/L2
6 0.24"
M10 5)
3/8-16 UNC
223 8.78"
1/L1
272 10.71"
23 4)
0.91"
5
40 1.57" 3)
12.5 0.49"
25
0.98"
67 2.64"
ø 6.2
0.24"
220 8.66"
EK550
1)
11
0.43"
1)
270 10.63"
11
0.43"
244 9.61"
ø11 0.43"
225.5 8.88"
2)
139.5 5.49"
8 0.31"
4)
23 0.91"
M10 5)
3/8-16 UNC
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
20
0.79"
67 2.64"
Dimension for extra auxiliary contact block
Screw, nut and washer by-packed
Min. distance to uninsulated wall
Damping elements are included
Earthing screw
223 8.78"
3/L2
299 11.77"
1/L1
1)
2)
3)
4)
5)
40 1.57"
3)
40 1.57"
EK1000
200 7.87"
F1
220 8.66"
M6 1/4-20 UNC
b)
271 10.67" - 282 11.1" - 293 11.54"
c)
1SBC101651S0201 - Rev. A
a)
a) Min. dim Makes distance F1 = 70
b) Includes space for three auxiliary contact blocks
between the contactors
c) Includes space for four auxiliary contact blocks
between the contactors
EK1000
ABB | 5/231
EK550, EK1000 4-pole contactors
DC operated
Main dimensions
mm, inches
296 11.65"
111)
0.43"
270 10.63"
244 9.61"
ø 11 0.43"
225.5 8.88"
2)
139.5 5.49"
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
200 7.87"
3/L2
6 0.24"
M10 5)
3/8-16 UNC
223 8.78"
1/L1
272 10.71"
23 4)
0.91"
5
40 1.57" 3)
ø 6.2
0.24"
12.5 0.49"
25
0.98"
67 2.64"
220 8.66"
EK550
1)
11
0.43"
296 11.65"
270 10.63"
244 9.61"
ø 11 0.43"
225.5 8.88"
2)
139.5 5.49"
8 0.31"
4)
23 0.91"
M105)
3/8-16 UNC
5/L3
7/L4
2/T1
4/T2
6/T3
8/T4
20
0.79"
67 2.64"
Dimension for extra auxiliary contact block
Screw, nut and washer by-packed
Min. distance to uninsulated wall
Damping elements are included
Earthing screw
223 8.78"
3/L2
299 11.77"
1/L1
1)
2)
3)
4)
5)
3)
40
1.57"
40 1.57"
EK1000
F1
220 8.66"
M6 1/4-20 UNC
a)
297 11.69" - 308 12.13"
EK1000
5/232 | ABB
b)
1SBC101653S0201 - Rev. A
200 7.87"
a) Min. dim.
b) Includes space for two auxiliary contact blocks
and the dc-unit between the contactors
Notes
N10
5
ABB | 5/233
Summary_5-4
5
5/234 | ABB
Contactors for DC switching
General description
5/236
Selection table for DC switching
AF09 ... AF96 contactors
5/238
AF116 ... AF2050 contactors
5/239
EK110 ... EK1000 contactors
5/240
Ordering details
100 A DC-1
GA75
AC operated
5/242
GAE75
DC operated
5/243
AC / DC operated
5/244
AC / DC operated
5/245
GAF1250 ... GAF2050 AC / DC operated
5/246
Main accessories
5/247
Technical data
5/248
Terminal marking and positionning
5/255
Main dimensions
5/256
Voltage code table
5/392
250 to 400 A DC-1
GAF185 ... GAF300
5
600 to 875 A DC-1
GAF460 ... GAF750
Summary_5-4
1040 to 1750 A DC-1
ABB | 5/235
Contactors for DC switching applications
DC-1, DC-3, DC-5 applications according to IEC 60947-4-1
The circuit switching on DC is more difficult than on AC, as alternating current go to zero according to the frequency of the
supply source while DC current has a continuous value.
The main parameters to be considered for selecting a contactor are the current, the voltage and the L/R time constant of the
controlled load.
Time constant and utilization categories
In DC applications, the nature of load to switch (resistor, inductance or a combination) is characterized by the ratio of the inductance to the resistance (L (inductance of operated circuit) / R (resistance of operated circuit) = mH/Ω = ms)
This ratio L/R is called the time constant of the circuit.
The higher the time constant value is, the more difficult it is to break the arc.
The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs, by reducing the time constant.
Operational voltage
– – The higher the operational voltage value is, the more difficult it is to break the arc.
– – The use of main poles connected in series will allow to increase the value of switched voltage.
However, the maximum switched voltage must be within the max operational voltage of the contactor.
All the poles required for breaking must be connected in series between the load and the source polarity not linked to earth
(or chassis) (see recommended connection diagrams).
ABB offer a large choice of possibilities for DC switching applications (see selection tables):
– – Standard 3-pole or 4-pole contactors with either 1- pole breaking or breaking with poles connected in series.
–– Special contactors designed for DC breaking with permanent magnets fitted on the main poles for use with the 3 poles connected in series and considered as 1-pole devices:
-- GA75 and GAE75 contactors: the 3 poles are connected in series via two supplied and fitted insulated connections (25 mm²)
- - GAF145 … GAF2050 contactors: the 3 poles must be connected in series by the user according to conductor cross-sectional area (refer to main pole technical data) or by using LP connection bars to be ordered separately.
Selection tables
The enclosed selection tables will guide your choice through all contactor variants according to utilization category, for operational voltage up to 1000 V DC-1 and operational current up to 2050 A in ambient temperatures from -25 °C up to 40 °C.
For higher values of current or voltage or heavy DC switching applications see bar mounted R contactors.
1SBC101980S0201
5
DC current utilization categories are defined according to IEC 60947-4-1:
–– DC-1 non inductive or slightly inductive loads, resistance furnaces (L/R ≤ 1 ms)
–– DC-3 shunt motors: starting, plugging, inching, dynamic breaking of DC motors (L/R ≤ 2 ms)
– – DC-5 series motors: starting, plugging, inching, dynamic breaking of DC motors (L/R ≤ 7.5 ms).
5/236 | ABB
Connection diagrams
Recommended connection
In the example below, the 3 poles are connected in series without the load in between.
This connection is recommended in systems according to the following configurations.
+
-
Load
Indirect earthed system
(isolated system)
Direct earthed system
Centre earthed system
5
Alternative connection (not possible for GA75, GAE75)
The load could be placed in between the contacts in a indirect earthed system. If not connected according to the configuration
below, a fault to earth could result in one or two contacts breaking the full load which the contactor is not approved for.
Load
+
-
Indirect earthed system
(isolated system)
Points to consider
The above relates to power circuit switching. The SCPD (Short Circuit Protection Device) must comply with applicable protection rules.
1SBC101980S0201
Polarity:
For all GA, GAE, GAF types, connection polarities must be respected.
(See instruction leaflet and see markings on the main terminals or the contactor front)
ABB | 5/237
AF09 ... AF96 contactors
DC circuit switching
General
The arc switching on DC is more difficult than on AC.
–– For selecting a contactor it is essential to determine the current, the voltage and the L/R time constant of the controlled load
–– For information, typical time constant values are quoted hereafter: non inductive loads such as resistance furnaces (L/R ≈ 1 ms), inductive loads
such as shunt motors (L/R ≈ 2 ms) or series motors (L/R ≈ 7.5 ms)
–– The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs
–– All the poles required for breaking must be connected in series between the load and the source polarity not linked to earth (or chassis).
Technical data
–– The tables indicate for the standard contactors the Ie max. operating currents depending on: the utilization category (i.e. L/R) DC-1, DC-3, DC-5
as defined in the IEC 60947-4-1 publication, the operating voltage Ue and the pole coupling details.
Ampere values quoted in these tables are valid for a -25…+70 °C temperature close to the contactors, as long as these values do not exceed
the AC-1 Ampere values for the corresponding ambient temperature
–– Max. switching frequency: 300 cycles/h.
Selection table
Contactor types
AF09
AF12
3 or 4-pole
AF26
3-pole
4-pole
AF30
3-pole
AF38
3-pole
4-pole
AF40
3-pole
AF52
3-pole
AF65
3-pole
AF80
3-pole
AF96
3-pole
A
45
45
45
45
45
45
45
45
45
-
50
50
50
50
50
50
-
A
50
50
50
50
50
50
-
A
55
55
55
55
55
55
55
55
55
-
70
70
70
70
70
70
-
A
100
100
100
100
100
100
-
A
105
105
105
105
105
105
-
A
125
125
125
125
125
125
-
A
130
130
130
130
130
130
-
A
A
A
A
A
A
A
A
A
A
A
45
45
45
45
45
45
-
Utilization category DC-3, L/R ≤ 2 ms
≤ 72 V 25 A
27 A
110 V 6 A
7A
220 V ≤ 72 V 25 A
27 A
110 V 25 A
27 A
220 V 6 A
7A
≤ 72 V 25 A
27 A
110 V 25 A
27 A
220 V 25 A
27 A
≤ 72 V 25 A
110 V 25 A
220 V 25 A
440 V 6 A
-
30 A
8A
30 A
30 A
8A
30 A
30 A
30 A
30 A
30 A
30 A
8A
45
45
45
45
45
45
-
A
-
50
50
50
50
50
50
-
A
50
50
50
50
50
50
-
A
-
70
70
70
70
70
70
-
A
100
100
100
100
100
100
-
A
105
105
105
105
105
105
-
A
125
125
125
125
125
125
-
A
130
130
130
130
130
130
-
A
Utilization category DC-5, L/R ≤ 7.5 ms
≤ 72 V 9 A
12 A
110 V 4 A
4A
220 V ≤ 72 V 25 A
27 A
110 V 10 A
15 A
220 V 4 A
4A
≤ 72 V 25 A
27 A
110 V 25 A
27 A
220 V 9 A
12 A
≤ 72 V 25 A
110 V 25 A
220 V 10 A
440 V 4 A
-
16 A
4A
30 A
20 A
4A
30 A
30 A
16 A
30 A
30 A
20 A
4A
20
45
45
45
45
20
-
A
-
25
50
50
50
50
25
-
A
25
50
50
50
50
25
-
A
-
70
70
70
70
70
70
-
A
100
100
100
100
100
100
-
A
105
105
105
105
105
105
-
A
125
125
125
125
125
125
-
A
130
130
130
130
130
130
-
A
Utilization category DC-1, L/R
≤ 72 V 25
110 V 10
220 V ≤ 72 V 25
110 V 25
220 V 10
≤ 72 V 25
110 V 25
220 V 25
≤ 72 V 25
110 V 25
220 V 25
440 V 10
≤ 1 ms
A
27
A
15
A
27
A
27
A
15
A
27
A
27
A
27
A
A
A
A
-
For additional ratings ≥ 440 V, please consult us.
5/238 | ABB
A
A
A
A
A
A
A
A
AF16
30
20
30
30
20
30
30
30
30
30
30
20
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
1SBC101911S0201
5
AF116 ... AF2050 contactors
DC circuit switching
5
Selection table
Contactor types
AF116 AF140 AF190 AF205 AF265 AF305 AF370 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650 AF2050
3-pole
Utilization category DC-1, L/R ≤ 1 ms
≤ 72 V
110 V
≤ 72 V
110 V
220 V
≤ 72 V
110 V
220 V
440 V
600 V
850 V
145
145
145
145
145
-
A
A
A
A
A
160
160
160
160
160
-
A
A
A
A
A
250
250
250
250
250
-
A
A
A
A
A
275
275
275
275
275
-
A
A
A
A
A
350
350
350
350
350
-
A
A
A
A
A
400
400
400
400
400
-
A
A
A
A
A
450
450
450
450
450
-
A
A
A
A
A
600
600
600
600
600
600
600
600
600
600
-
A
A
A
A
A
A
A
A
A
A
700
700
700
700
700
700
700
700
700
700
-
A
A
A
A
A
A
A
A
A
A
800
800
800
800
800
800
800
800
800
800
800
A
A
A
A
A
A
A
A
A
A
A
1050
1050
1050
1050
1050
1050
1050
1050
1050
1050
1050
A
A
A
A
A
A
A
A
A
A
A
1250
1250
1250
1250
1250
1250
1250
1250
1250
1250
A
A
A
A
600
600
600
600
600
600
600
600
600
600
A
A
A
A
A
A
A
A
A
A
700
700
700
700
700
700
700
700
700
700
A
A
A
A
A
A
A
A
A
A
800
800
800
800
800
800
800
800
800
800
A
A
A
A
A
A
A
A
A
A
1050
1050
1050
1050
1050
1050
1050
1050
1050
1050
A
A
A
A
A
A
A
A
A
A
-
-
-
-
600
600
600
600
600
600
600
600
600
600
A
A
A
A
A
A
A
A
A
A
700
700
700
700
700
700
700
700
700
700
A
A
A
A
A
A
A
A
A
A
800
800
800
800
800
800
800
800
800
800
A
A
A
A
A
A
A
A
A
A
1050
1050
1050
1050
1050
1050
1050
1050
1050
1050
A
A
A
A
A
A
A
A
A
A
-
-
-
-
A
A
A
A
A
A
1350
1350
1350
1350
1350
1350
1350
1350
1350
1350
A
A
A
A
A
A
A
A
A
A
1650
1650
1650
1650
1650
1650
1650
1650
1650
1650
A
A
A
A
A
A
A
A
A
A
2050
2050
2050
2050
2050
2050
2050
2050
2050
2050
A
A
A
A
A
A
A
A
A
A
Utilization category DC-3, L/R ≤ 2 ms
≤ 72 V
110 V
≤ 72 V
110 V
220 V
≤ 72 V
110 V
220 V
440 V
600 V
145
145
145
145
145
-
A
A
A
A
A
160
160
160
160
160
-
A
A
A
A
A
250
250
250
250
250
-
A
A
A
A
A
275
275
275
275
275
-
A
A
A
A
A
350
350
350
350
350
-
A
A
A
A
A
400
400
400
400
400
-
A
A
A
A
A
450
450
450
450
450
-
A
A
A
A
A
Utilization category DC-5, L/R ≤ 7.5 ms
≤ 72 V
110 V
≤ 72 V
110 V
220 V
≤ 72 V
110 V
220 V
440 V
600 V
145
145
145
145
145
-
A
A
A
A
A
160
160
160
160
160
-
A
A
A
A
A
250
250
250
250
250
-
A
A
A
A
A
275
275
275
275
275
-
A
A
A
A
A
350
350
350
350
350
-
A
A
A
A
A
400
400
400
400
400
-
A
A
A
A
A
450
450
450
450
450
-
A
A
A
A
A
1SBC101944S0201
For additional ratings ≥ 440 V, please consult us.
ABB | 5/239
EK110 ... EK1000 contactors
DC circuit switching
Selection table
Contactor types
EK150
EK175
EK210
EK370
EK550
EK1000
120
120
200
200
200
200
200
200
–
–
200
200
200
200
–
145
145
200
200
200
200
200
200
–
–
200
200
200
200
–
210
210
300
300
300
300
300
300
210
–
300
300
300
260
260
210
210
300
300
300
300
300
300
210
–
300
300
300
260
260
370
370
550
550
550
550
550
550
450
450
550
550
550
450
450
550
550
800
800
800
800
800
800
650
650
800
800
800
650
650
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
120
135
135
135
135
135
135
–
–
135
135
135
135
–
145
145
135
135
145
135
135
–
–
145
135
135
135
–
210
210
210
210
210
210
210
210
–
210
210
210
210
170
210
210
210
210
210
210
210
210
–
210
210
210
210
210
370
450
450
450
450
450
450
450
450
450
450
450
450
450
550
650
650
650
650
650
650
650
650
650
650
650
650
650
–
–
–
–
–
–
–
–
–
–
–
–
–
–
135
135
135
135
135
135
–
–
135
135
135
135
–
145
135
135
145
135
135
–
–
145
135
135
135
–
210
210
210
210
210
210
210
–
210
210
210
210
170
210
210
210
210
210
210
210
–
210
210
210
210
210
450
450
450
450
450
450
450
450
450
450
450
450
450
650
650
650
650
650
650
650
650
650
650
650
650
650
–
–
–
–
–
–
–
–
–
–
–
–
–
A 832D
A 831D
A 830D
A 829D
Utilization category DC-1, L/R ≤ 1 ms
≤ 72 V
110 V
≤ 72 V
110 V
220 V
≤ 72 V
110 V
220 V
440 V
600 V
≤ 72 V
110 V
220 V
440 V
600 V
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A 832D
A 831D
A 830D
A 829D
Utilization category DC-3, L/R ≤ 2 ms
≤ 72 V
≤ 72 V
110 V
220 V
≤ 72 V
110 V
220 V
440 V
600 V
≤ 72 V
110 V
220 V
440 V
600 V
A
A
A
A
A
A
A
A
A
A
A
A
A
A
5/240 | ABB
≤ 72 V
110 V
220 V
≤ 72 V
110 V
220 V
440 V
600 V
≤ 72 V
110 V
220 V
440 V
600 V
A
A
A
A
A
A
A
A
A
A
A
A
A
1SBC101986S0201
A 831D
A 830D
Utilization category DC-5, L/R ≤ 7.5 ms
A 832D
5
EK110
Notes
N6
5
ABB | 5/241
GA75 1-pole contactors
100 A DC-1
AC operated
1SBC586544F0301
Description
GA75-10-11
GA75 contactors are designed for controlling shunt or series motors and resistive or slightly inductive loads
up to 1000 V DC.
These contactors are of the block type design with 3 main poles connected in series.
–– main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection
polarities must be respected.
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
current
θ ≤ 55 °C
440 V
DC-1
A
100
5
UL / CSA
Rated control circuit
General use rating voltage
Uc
(1)
440 V DC
A
100
Auxiliary Type
contacts
fitted
V 50 Hz
24
V 60 Hz
24
48
48
110
110…120
220…230
230…240
230…240
240…260
380…400
400…415
400…415
415…440
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
GA75-10-00
GA75-10-11
GA75-10-00
GA75-10-11
GA75-10-00
GA75-10-11
GA75-10-00
GA75-10-11
GA75-10-00
GA75-10-11
GA75-10-00
GA75-10-11
GA75-10-00
GA75-10-11
Order code
Weight
Pkg
(1 pce)
1SBL411025R8100
1SBL411025R8111
1SBL411025R8300
1SBL411025R8311
1SBL411025R8400
1SBL411025R8411
1SBL411025R8000
1SBL411025R8011
1SBL411025R8800
1SBL411025R8811
1SBL411025R8500
1SBL411025R8511
1SBL411025R8600
1SBL411025R8611
kg
1.220
1.260
1.220
1.260
1.220
1.260
1.220
1.260
1.220
1.260
1.220
1.260
1.220
1.260
(1) Other control voltages see voltage codes table.
35 mm x15 EN/IEC 60715
mm, inches
70 2.76"
110 4.33"
6
0.24"
6.5
0.26"
GA75-10-11
10 0.39"
72 2.83"
10
0.39"
1SBC101423S0201
11 0.43"
12 0.47"
5/242 | ABB
108 4.25"
72 2.83"
4
0.16"
75 mm EN/IEC 60715
11
0.43"
Main dimensions
GAE75 1-pole contactors
100 A DC-1
DC operated
Description
Ordering details
IEC
Rated operational
current
θ ≤ 55 °C
440 V
DC-1
A
100
UL/CSA
Rated control circuit
General use rating voltage
Uc
(1)
440 V DC
A
100
Auxiliary Type
contacts
fitted
V DC
12
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
24
48
60
110
125
220
240
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
GAE75-10-00
GAE75-10-11
Order code
Weight
Pkg
(1 pce)
1SBL419025R8000
1SBL419025R8011
1SBL419025R8100
1SBL419025R8111
1SBL419025R8300
1SBL419025R8311
1SBL419025R8400
1SBL419025R8411
1SBL419025R8600
1SBL419025R8611
1SBL419025R8700
1SBL419025R8711
1SBL419025R8800
1SBL419025R8811
1SBL419025R8900
1SBL419025R8911
5
kg
1.260
1.300
1.260
1.300
1.260
1.300
1.260
1.300
1.260
1.300
1.260
1.300
1.260
1.300
1.260
1.300
(1) Other control voltages see voltage codes table.
mm, inches
35 mm x15 EN/IEC 60715
Main dimensions
82 3.23"
108 4.25"
72 2.83"
6
0.24"
6.5
0.26"
12 0.47"
10 0.39"
72 2.83"
1SBC101424S0201
11 0.43"
4
0.16"
75 mm EN/IEC 60715
11
0.43"
GAE75-10-11
These contactors are of the block type design with 3 main poles connected in series.
–– main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection
polarities must be respected.
–– control circuit: DC operated with double winding coil (and factory mounted lagging contact for "holding"
winding insertion)
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories
110 4.33"
1SBC586554F0301
GAE75 contactors are designed for controlling shunt or series motors and resistive or slightly inductive loads
up to 1000 V DC.
10
0.39"
GAE75-10-11
ABB | 5/243
GAF185 ... GAF300 3-pole contactors
250 to 400 A DC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contact
Description
GAF185 ... GAF300 contactors are designed for controlling resistive or slightly inductive loads up to 1000 V DC.
1SFC101098F0001
These contactors are of the block type design with 3 main poles for connection in series by the user according to conductor cross-sectional area or by using LP connection bars to be ordered separately.
–– main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection
polarities must be respected.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 3 coils to cover control voltages between 48...250 V 50/60 Hz and
20...250 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
GAF185-10-11
5
1SFC101099F0001
Ordering details
GAF300-10-11
IEC
Rated operational
current
θ ≤ 55 °C
1000 V
DC-1
A
250
UL / CSA
General use
rating
θ ≤ 40 °C
1000 V DC
Rated control circuit
voltage
Uc
A
250 (2)
400
400
V 50/60 Hz
48…130
100…250
48…130
100…250
V DC
20…60
48…130
100…250
20…60
48…130
100…250
Auxiliary Type
contacts
fitted
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
Pkg
(1 pce)
GAF185-10-11 (1)
GAF185-10-11
GAF185-10-11
GAF300-10-11 (1)
GAF300-10-11
GAF300-10-11
kg
3.600
3.600
3.600
6.200
6.200
6.200
1SFL497025R7211
1SFL497025R6911
1SFL497025R7011
1SFL557025R7211
1SFL557025R6911
1SFL557025R7011
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
(2) At 660 V DC.
Main dimensions
mm, inches
12
0.47"
111.5 4.39"
105 4.13"
ø 8.5 0.33"
160 6.3"
35.5
1.4"
140 5.51"
17.5 0.69"
180.5 7.11"
ø 10.2
0.4"
35.5 1.4"
5 0.2"
5 0.2"
GAF185
5/244 | ABB
43.75 1.72"
GAF300
1SFC101023C0201 - Rev. A
35
1.38"
227 8.94"
219 8.62"
196 7.72"
187 7.36"
14 0.55"
17.5
0.69"
10 0.39"
12
0.47"
GAF460 ... GAF750 3-pole contactors
600 to 875 A DC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contact
Description
GAF460 ... GAF750 contactors are designed for controlling resistive or slightly inductive loads up to 1000 V DC.
1SFC101100F0001
These contactors are of the block type design with 3 main poles for connection in series by the user according to conductor cross-sectional area or by using LP connection bars to be ordered separately.
–– main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection
polarities must be respected.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and
24...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
GAF460-10-11
5
UL / CSA
General use
rating
θ ≤ 40 °C
1000 V DC
Rated control circuit
voltage
Uc
A
650
875
900
V 50/60 Hz
48…130
100…250
250…500
48…130
100…250
250…500
V DC
24…60
48…130
100…250
250…500
24…60
48…130
100…250
250…500
Auxiliary Type
contacts
fitted
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
Pkg
(1 pce)
GAF460-10-11 (1)
GAF460-10-11
GAF460-10-11
GAF460-10-11
GAF750-10-11 (1)
GAF750-10-11
GAF750-10-11
GAF750-10-11
kg
12.000
12.000
12.000
12.000
15.000
15.000
15.000
15.000
1SFL597025R6811
1SFL597025R6911
1SFL597025R7011
1SFL597025R7111
1SFL637025R6811
1SFL637025R6911
1SFL637025R7011
1SFL637025R7111
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
GAF460 ... GAF750 are equipped with low voltage inputs for control, for example by a PLC.
Control inputs
mm, inches
210 8.27"
216 8.5"
48.5 1.91"
40 1.57"
6 0.24"
63 2.48"
GAF460
22.5
0.89"
ø6.5
0.26"
ø12.5
0.49"
242 9.53"
48.5 1.91"
6 0.24"
1SFC101024C0201 - Rev. A
ø10.5
0.41"
11.5 0.45"
ø6.5
0.26"
283 11.14"
22.5
0.89"
273 10.75"
186 7.32"
25
0.98"
11.5 0.45"
Main dimensions
278 10.94"
GAF750-10-11
IEC
Rated operational
current
θ ≤ 55 °C
1000 V
DC-1
A
600
268 10.55"
1SFC101102F0001
Ordering details
72 2.83"
GAF750
ABB | 5/245
GAF1250 ... GAF2050 3-pole contactors
1040 to 1750 A DC-1
AC / DC operated with 1 N.O. + 1 N.C. auxiliary contact
Description
GAF1250 ... GAF2050 contactors are designed for controlling resistive or slightly inductive loads up to 1000 V DC.
1SFC101004F0201
These contactors are of the block type design with 3 main poles for connection in series by the user according to conductor cross-sectional area or by using LP connection bars to be ordered separately.
–– main poles arc chutes fitted with permanent magnets specially designed for DC breaking. The connection
polarities must be respected.
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 48...500 V 50/60 Hz and
24...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
GAF1250-10-11
5
1SFC101004F0201
Ordering details
GAF1650-10-11
IEC
Rated operational
current
θ ≤ 55 °C
1000 V
DC-1
A
1040
UL / CSA
General use
rating
θ ≤ 40 °C
1000 V
Rated control circuit
voltage
Uc
A
1210
1450
1750
1650
2050
V 50/60 Hz
48…130
100…250
250…500
100…250
100…250
Auxiliary Type
contacts
fitted
V DC
24…60
48…130
100…250
250…500
100…250
100…250
1
1
1
1
1
1
1
1
1
1
1
1
Order code
Weight
Pkg
(1 pce)
GAF1250-10-11
GAF1250-10-11
GAF1250-10-11
GAF1250-10-11
GAF1650-10-11
GAF2050-10-11
kg
16.000
16.000
16.000
16.000
35.000
35.000
1SFL647025R6811
1SFL647025R6911
1SFL647025R7011
1SFL647025R7111
1SFL677025R7011
1SFL707025R7011
GAF1250 ... AF2050 are equipped with low voltage inputs for control, for example by a PLC
Control inputs
40 1.57"
27
27
27
1.06"
1.06"
13 0.51"
13 0.51"
ø 13.5 ø 13.540
0.53" 0.53"1.57"
17 0.67"
17 0.67"
40 1.57"
17 0.67"
17 0.67"
AF2050
GAF1650
GAF2050
40 1.57"
40 1.57"
136 5.35"
136 5.35"
3
0.12"
136 5.35"
136 5.35"
136 5.35"
136 5.35"
242 9.53"
3
3
0.12"
0.12"
GAF1250
5/246 | ABB
210 8.27"
72 2.83"
46.5
18.3"
8 0.31"
1SFC101125F0001
72 2.83"
ø13 0.51"
1SFC101124F0001
312 12.28"
80
3.15"
104
4.09"
80
80
136 5.35"
136 5.35"ø9 0.35"
ø9 0.35"
3.15" 3.15"
104
104
4.09" 4.09"
438 17.24"
438 17.24"
GAF1650, GAF2050
312 12.28"
312 12.28"
392 15.43"
392 15.43"
249 9.8"
263 10.35"
313 12.32"
344 13.54"
392 15.43"
1.06"
136 5.35"
ø9 0.35"
47
1.85"
438 17.24"
47
1.85"
47
10 0.39"
10 0.39"
1.85"
244 9.61"
244 9.61"
10 0.39"
1SFC101025C0201 - Rev. A
ø 7 0.28"
72 2.83"
17 0.67"
30 1.18"
AF2050AF2050
AF1350,AF1350,
AF1650AF1650
50 1.97"
27
40
1.57" 10 0.39"
AF1350, AF1650
10 0.39"
10 0.39"
mm, inches
40
1.57"
17 0.67"
13 0.51"
30 1.18"
30 1.18"
Main dimensions
ø 13.5
0.53"
1.06"
40 1.57"
40 1.57"
244 9.61"
1SFC101114F0001
GAF185 ... GAF2050 3-pole contactors
Main accessories
Ordering details
For contactors
Auxiliary Type
contacts
Order code
Pkg
qty
LP185
kg
Auxiliary contact blocks, low energy microswitch 0.1 A, N.O. or N.C.
GAF185 ... GAF2050
0 1
CEL18-01
1SFN010716R1001
1 0
CEL18-10
1SFN010716R1010
Connection bar for contactor
GAF185
GAF300
GAF460
GAF750
GAF1250
GAF1650, GAF2050
LP185
LP300
LP460
LP750
LP1250
LP2050
1SFN074712R1000
1SFN075112R1000
1SFN075712R1000
1SFN076112R1000
1SFN076412R1000
1SFN076512R1000
0.050
0.050
2
2
4
4
2
4
0.300
0.400
0.550
0.950
1.900
2.900
5
1SFC101185C0201
1SFC101117F0001
LP2050
Weight
(1 pce)
ABB | 5/247
GA75 ... GAF2050 contactors
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
AC operated
DC operated
AC / DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
DC-1 Utilization category, L/R ≤ 1 ms
For air temperature close to contactor
Ie / Rated operational current DC-1
θ ≤ 40 °C
θ ≤ 55 °C
5
θ ≤ 70 °C
DC-5 Utilization category, L/R ≤ 7.5 ms
Ie / Rated operational current DC-5
θ ≤ 55 °C
GAF185
GAF300
GAF460
GAF750
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
1000 V DC
50 / 60 Hz
220 V
440 V
600 V
1000 V
220 V
440 V
600 V
1000 V
220 V
440 V
600 V
1000 V
120 A
100 A
75 A
35 A
100 A
100 A
75 A
35 A
85 A
85 A
75 A
35 A
(1)
275
250
180
150
220 V
440 V
100 A
85 A
-
220 V
440 V
85 A
35 A
300 cycles/h
With conductor cross-sectional area
DC-3 Utilization category, L/R ≤ 2 ms
Ie / Rated operational current DC-3
θ ≤ 55 °C
GA75
GAE75
Maximum electrical switching frequency
GAF1250
GAF1650
GAF250
A
500 A
700 A
1050 A
1250 A
1650 A
2050 A
A
400 A
600 A
875 A
1040 A
1450 A
1750 A
A
mm²
325 A
300 mm²
(2)
480 A
2x
240 mm²
720 A
2x
50x8 mm²
875 A
1270 A
1500 A
2x
3x
4x
100x5 mm² 100x5 mm² 100x5 mm²
(1) Refer to IEC 60947-1, table 9.
(2) For currents above 450 A, use 300 mm² and terminal extension/enlargement pieces (LX300/LW300).
Main pole - Utilization characteristics according to UL / CSA
Contactor types
Standards
Maximum operational voltage
UL / CSA DC general use rating
θ ≤ 40 °C
Maximum electrical switching frequency
AC operated
DC operated
AC / DC operated
440 V
600 V
1000 V
GA75
GAE75
GAF185
GAF300
GAF460
GAF750
GAF1250
UL 508, CSA C22.2 N°14 UL 60947-4-1, CSA C22.2 N°60947.4-1
1000 V DC
100 A
75 A
250 A
35 A
(3)
300 cycles/h
400 A
400 A
650 A
900 A
1210 A
GAF1650
GAF250
1650 A
2050 A
1SBC101982S0201
(3) On request.
5/248 | ABB
GA75 and GAE75 contactors
Technical data
General technical data
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor
Operation
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
B2
C2
GA75
GAE75
1000 V
600 V
8 kV
-40…+70 °C
-60...+80 °C
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
3000 m
10 millions operating cycles (5 millions for GAE75)
3600 cycles/h
Shock direction
A
B1
B2
C1
C2
5
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
20 g
10 g closed position / 5 g open position
15 g
20 g
20 g
1SBC101983S0201
Contactor types
ABB | 5/249
GAF185 ... GAF2050 contactors
Technical data
General technical data
C1
A
ABB
A
B1
B2
C2
Shock direction
A
B1
B2
C1
C2
GAF185
GAF300
GAF460
GAF750
GAF1250
GAF1650
GAF2050
1000 V
600 V
8 kV
-40 to +70 °C
-40 to +70 °C
acc. to IEC 60068-2-30
3000 m
5 millions operating cycles
300 cycles/h
0.5 millions operating cycles
60 cycles/h
1/2 sinusoidal shock for 30 ms: no change in contact position, closed or open position
5g
5g
5g
5g
5g
-
1SFC101178C0201
5
AC / DC operated
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor
Operation
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
5/250 | ABB
GA75 and GAE75 contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC control voltage
Rated control circuit voltage Uc
Coil consumption
AC operated
AC supply
Average pull-in value
Average holding value
Drop-out voltage
Operating time
Between coil energization and:
at 50 Hz
at 60 Hz
50 Hz
60 Hz
50/60 Hz (1)
50 Hz
60 Hz
50/60 Hz (1)
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
Between coil de-energization and:
GA75
At θ ≤ 55 °C 0.85...1.1 x Uc
Please also refer to "Mounting characteristics and conditions for use"
24…690 V
24…690 V
180 VA
210 VA
190 VA / 180 VA
18 VA / 5.5 W
18 VA / 5.5 W
18 VA / 5.5 W
Approx. 40...65 % of Uc
8…27
7…22
4…11
7…14
5
ms
ms
ms
ms
(1) 50/60 Hz coils: see "Voltage code table".
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
DC control voltage
Rated control circuit voltage Uc
Coil consumption
DC operated
AC supply
Average pull-in value
Average holding value
Drop-out voltage
Coil time constant
Open
Closed
Operating time
Between coil energization and:
L/R
L/R
N.O. contact closing
N.C. contact opening
Between coil de-energization and: N.O. contact opening (1)
N.C. contact closing (1)
GAE75
At θ ≤ 55 °C 0.85...1.1 x Uc
Please also refer to "Mounting characteristics and conditions for use"
12…250 V DC
200 W
4W
Approx. 15...40 % of Uc
3 ms
15 ms
13…30 ms
10…27 ms
5…15 ms
8…18 ms
(1) The use of surge suppressors increases the opening time with a factor of 1.1 to 1.5 for a RV5 surge suppressor and a factor of 1.5 to 3 for RT5 surge suppressor.
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
GA75
GAE75
Mounting positions
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Pos. 1
6
at θ ≤ 55 °C
at θ ≤ 70 °C
at θ ≤ 55 °C
at θ ≤ 70 °C
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 5
Pos. 6
0.85…1.1 x Uc
Uc
0.95...1.1 x Uc
Unauthorized
The contactors can be assembled side by side
1SBC101981S0201
Control voltage / Ambient temperature
Mounting
1, 1±30°, 2, 3, 4, 5
positions
Pos. 1 ± 30°
35 x 15 mm or 75 x 25 mm
2 x M6 screws placed diagonally
ABB | 5/251
GAF185 ... GAF2050 contactors
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Coil consumption
Between coil de-energization and:
Control input for PLC's
Between coil energization and:
Between coil de-energization and:
AC or DC supply
Average pull-in value
Average holding value
Average pull-in value
Average holding value
GAF185
GAF300
GAF460
GAF750
GAF1250
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max.
Please also refer to "Mounting characteristics and conditions for use"
GAF1650
GAF2050
48...250 V AC
48…500 V AC
430 VA
470 VA
890 VA
850 VA
12 VA / 3.5 W 10 VA / 2.5 W 12 VA / 4 W 12 VA / 4.5 W
100…250 V AC
1900 VA
48 VA / 17 W
20…250 V DC
500 W
520 W
2W
55 % of Uc min.
24…500 V DC
990 W
950 W
4W
4.5 W
100…250 V DC
1700 W
16 W
50…80
50…80
35…55
35…55
ms
ms
ms
ms
40…65
40…65
10…30
10…30
ms
ms
ms
ms
≥ 20 ms
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
30…115 ms
30…115 ms
25…80 ms
25…80 ms
50…120 ms
50…120 ms
33…70 ms
33…70 ms
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
-
40…60
40…60
10…30
10…30
ms
ms
ms
ms
40...90 ms
40...90 ms
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
GAF185
GAF300
Pos. 2
+30°
GAF460
GAF750
GAF1250
GAF1650
GAF2050
-30°
Pos. 4
Pos. 3
Pos. 1
Control voltage / Ambient temperature
Mounting
1, 1±30°, 2, 3, 4, 5
positions
6
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
at θ ≤ 70 °C
Pos. 1 ± 30°
Pos. 5
Pos. 6
0.85 x Uc min…1.1 x Uc max.
Unauthorized
The contactors can be assembled side by side
–
4 x M5
4 x M6
4 x M8
1SFC101177C0201
5
Drop-out voltage
Dips withstand
-20 °C ≤ θ ≤ +60 °C
Operating time
Coil supply between A1 - A2
Between coil energization and:
AC / DC operated
5/252 | ABB
GA75 and GAE75 contactors
Technical data
Connecting characteristics
Contactor types
AC operated
DC operated
GA75
GAE75
Main terminals
Screw terminals with single connector (13 x 10 mm)
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with ferrule
Bars or lugs
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Auxiliary conductors
(coil terminals)
Rigid solid
Flexible with ferrule
l L
Lugs
6...50 mm²
6...25 mm²
6...35 mm²
6...16 mm²
–
–
AWG 8…1
4.00 Nm / 35 lb.in
4.50 Nm
1x
2x
1x
2x
L≤
l>
1 or 2 x
1…4 mm²
1…4 mm²
1…2.5 mm²
0.75…2.5 mm²
8 mm
3.7 mm
AWG 18...14
Connection capacity acc. to UL / CSA
Tightening torque
Coil terminals
Recommended
Max.
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Screw terminals
Main terminals
Coil terminals
5
1.00 Nm / 9 lb.in
1.20 Nm
IP10
IP20
Delivered in open position, screws of unused terminals must be tightened
M6
Screwdriver type Flat Ø 6.5 / Pozidriv 2
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101984S0201
l L
1x
2x
1x
2x
L≤
l>
1 or 2 x
ABB | 5/253
GAF185 ... GAF2050 contactors
Technical data
Connecting characteristics
Contactor types
Main terminals
Flat type
AC / DC operated
GAF185
GAF300
GAF460
GAF750 GAF1250 GAF1650 GAF2050
80
10
40
17
40
50
27
15.5
8
AF2050
25
ø 13
80
40
5
6
25
6
22.5
ø 6.5
ø 10.2
ø 8.5
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid with
Single for Cu cable
connector
Single for Al/Cu cable
Double for Al/Cu cable
L≤
Bars or lugs
ø L
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Auxiliary conductors
(coil terminals)
Rigid solid
Flexible with ferrule
l L
Lugs
6…185 mm²
25…150 mm²
–
24 mm
Ø > 8 mm
1 or 2 x 6 - 250 MCM
18 Nm /
160 Ib.in
20 Nm
1x
2x
1x
2x
L≤
l>
1 or 2 x
16…240 mm²
120…240 mm²
2 x 95…120 mm²
32 mm
10 mm
4 - 500 MCM (1)
28 Nm /
247 lb.in
30 Nm
17
40
22.5
10
17.5
5
5
20
10
30
AF1250
27
ø 12.5
AF750
ø 10.5 ø 6.5
240 mm²
240 mm²
2 x 240 mm²
47 mm
10 mm
2//250 - 500 MCM
35 Nm /
310 Ib.in
40 Nm
300 mm²
300 mm²
3 x 185 mm²
52 mm
12 mm
3// 2/0 - 500 MCM
45 Nm /
398 lb.in
49 Nm
M10
M12
ø 13
AF1650
–
–
–
100 mm
12 mm
1/0 - 750 MCM
45 Nm /
398 lb.in
49 Nm
1…4 mm²
1…4 mm²
0.75…2.5 mm²
0.75…2.5 mm²
8 mm
3.7 mm
AWG 18…14
1.00 Nm / 9 lb.in
1.20 Nm
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
IP00
Coil terminals
IP20
Screw terminals
Main terminals
M8
M10
Screws and bolts
Coil terminals (delivered in open position)
M3.5
Screwdriver type Flat Ø 5.5 mm / Pozidriv 2
1SFC101179C0201
(1) With LW110 enlargement piece: see "Accessories".
5/254 | ABB
GA75 ... GAF2050 contactors
Terminal marking and positioning
GA75 contactors - AC operated
Standard devices without addition of auxiliary contacts
A1
A2
A1
1L1 +
A2
1L1 +
NO 13X
1L1 +
1L1 +
A1
NC 21X
13X
21X
14X
22X
A1
NC 22X
NO 14X
2T1 –
2T1 –
A2
A2
GA75-10-00
A2
A2
2T1 –
GA75-10-11
2T1 –
GA75-10-00
GA75-10-11
5
GAE75 contactors - DC operated
Standard devices without addition of auxiliary contacts
A1
A2
A1
1L1 +
A2
1L1 +
35X
35X
NO 13X
C
D
L
5
C
D
L
5
NC 21X
NC 22X
NO 14X
36X
35X
1L1 +
1L1 +
13X
21X
14X
22X
A1
36X
2T1 –
2T1 –
A3
A3
GAE75-10-00
35X
A1
A2
36X
GAE75-10-11
GAF185 ... GAF2050 contactors -
A2
A3
GAE75-10-00
A3
36X
2T1 –
2T1 –
GAE75-10-11
AC / DC operated
+
GAF2050-10
Ith=2050A
Ui = 1000V DC
Ie DC-1 = 2050A
Ue = 1000V DC
IEC 60947-4-1
1G1129
EN 60947-4-1
All 3 poles must be
connected in series
Device equipped with
permmanent magnets
1L1 +
13X
21X
14X
22X
A1
GAF185 ... GAF2050-10-11
A2
2T1 –
GAF185 ... GAF2050-10-11
1SBC101985S0201
Connection bars are sold separately
ABB | 5/255
GA75 1-pole contactor
GAE75 1-pole contactor
75 mm EN/IEC 60715
11 0.43"
100 3.94"
ø 6.2 0.24"
M6 1/4-20 UNC
6.5
0.26"
90 3.54"
10 0.39"
72 2.83"
10
0.39"
5
0.2"
60 2.36"
5
0.2"
110 4.33"
82 3.23"
108 4.25"
72 2.83"
6
0.24"
10 0.39"
72 2.83"
10
0.39"
5
0.2"
60 2.36"
5
0.2"
GAE75
1SBC101491S0201
GAE75-10-11
75 mm EN/IEC 60715
11
0.43"
11 0.43"
4
0.16"
12 0.47"
ø 6.2 0.24"
M6 1/4-20 UNC
6.5
0.26"
90 3.54"
35 mm x15 EN/IEC 60715
GA75
100 3.94"
11
0.43"
11
0.43"
11
0.43"
110 4.33"
GAE75-10-00
6
0.24"
GA75-10-11
GA75-10-00
82 3.23"
108 4.25"
72 2.83"
4
0.16"
11
0.43"
110 4.33"
110 4.33"
70 2.76"
12 0.47"
70 2.76"
5
35 mm x15 EN/IEC 60715
mm, inches
11
0.43"
Main dimensions
5/256 | ABB
GAF185, GAF300 3-pole contactor
Main dimensions
mm, inches
111.5 4.39"
105 4.13"
ø 8.5 0.33"
160 6.3"
35.5
1.4"
5 0.2"
35
1.38"
165 6.5"
196 7.72"
187 7.36"
17.5
0.69"
10 0.39"
12
0.47"
5
M5 10-24 UNC
35
1.38"
GAF185-30-11
12
0.47"
GAF185-30-11
140 5.51"
180.5 7.11"
ø 10.2
0.4"
35.5 1.4"
5 0.2"
43.75 1.72"
187 7.36"
227 8.94"
219 8.62"
14 0.55"
17.5 0.69"
M5 10-24 UNC
43.75 1.72"
GAF300-30-11
1SFC101180C0201
GAF300-30-11
ABB | 5/257
GAF460 3-pole contactor
mm, inches
186 7.32"
ø6.5
0.26"
ø10.5
0.41"
268 10.55"
216 8.5"
48.5 1.91"
6 0.24"
63 2.48"
GAF460-30-11
63 2.48"
248 9.76"
M5 10-24 UNC
1SFC101181C0201
5
22.5
0.89"
278 10.94"
25
0.98"
11.5 0.45"
Main dimensions
5/258 | ABB
GAF750 3-pole contactor
Main dimensions
210 8.27"
22.5
0.89"
ø6.5
0.26"
ø12.5
0.49"
242 9.53"
48.5 1.91"
6 0.24"
283 11.14"
273 10.75"
40 1.57"
11.5 0.45"
mm, inches
5
72 2.83"
GAF750-30-11
249 9.8"
72 2.83"
1SFC101182C0201
M6 1/4-20 UNC
ABB | 5/259
GAF1250 3-pole contactor
Main dimensions
mm, inches
50 1.97"
27
72 2.83"
ø 7 0.28"
242 9.53"
72 2.83"
210 8.27"
46.5
18.3"
8 0.31"
1SFC101125F0001
72 2.83"
ø13 0.51"
1SFC101124F0001
249 9.8"
263 10.35"
313 12.32"
GAF1250-30-11
72 2.83"
1SFC101183C0201
M6 1/4-20 UNC
1SFC101130F0001
249 9.8"
5
344 13.54"
1.06"
5/260 | ABB
GAF1650, GAF2050 3-pole contactor
Main dimensions
mm, inches
40 1.57"
40 1.57"
27
27
ø 13.5
1.06"
0.53"
1.06"
40
ø 13.5
0.53"
1.57"
17 0.67"
13 0.51"
30 1.18"
13 0.51"
10 0.39"
GAF1650
AF1350, AF1650
17 0.67"
17 0.67"
17 0.67"
30 1.18"
40 1.57"
10 0.39"
40 1.57"
GAF2050
AF2050
AF1350, AF1650
136 5.35"
136 5.35"
40
1.57"
AF2050
136 5.35"
136 5.35"
3
3
0.12"
0.12"
80
3.15"
104
4.09"
136 5.35"
438 17.24"
ø9
80 0.35"
3.15"
104
4.09"
0.39"
136 5.35" 47
ø910
0.35"
1.85"
244 9.61"
312 12.28"
312 12.28"
392 15.43"
392 15.43"
5
47
1.85"
10 0.39"
244 9.61"
438 17.24"
GAF1650, GAF2050-30-11
1SFC101184C0201
312 12.28"
136 5.35"
M8 5/16-18 UMC
ABB | 5/261
Summary_5-5
5
5/262 | ABB
Contactors for capacitor switching
Overview 5/264
UA16..RA up to UA110..RA - Unlimited peak Î
Ordering details
5/266
Main accessories
5/269
Technical data
5/270
Terminal marking and positioning
5/272
Main dimensions
5/273
UA16 up to UA110 - Peak current Î ≤ 100 times the rms current
Ordering details
5/276
Main accessories
5/281
5/282
Terminal marking and positioning
5/284
Main dimensions
5/285
Voltage code table
5/392
5
Summary_5-5
Technical data
ABB | 5/263
Contactors for capacitor switching
AC-6b utilization category according to IEC 60947-4-1
Capacitor transient conditions
In Low Voltage industrial installations, capacitors are mainly used for reactive energy correction (raising the power factor). When these capacitors
are energized, overcurrents of high amplitude and high frequencies (3 to 15 kHz) occur during the transient period (1 to 2 ms).
The amplitude of these current peaks, also known as "inrush current peaks", depends on the following factors:
–– The network inductances.
–– The transformer power and short-circuit voltage.
–– The type of power factor correction.
There are 2 types of power factor correction: fixed or automatic.
Fixed power factor correction consists of inserting, in parallel on
the network, a capacitor bank whose total power is provided by the
assembly of capacitors of identical or different ratings.
The bank is energized by a contactor that simultaneously supplies all
the capacitors (a single step).
An electronic device automatically determines the power of the
steps to be energized and activates the relevant contactors.
The inrush current peak, in the case of automatic correction, depends on the power of the steps already on duty, and can reach 100
times the nominal current of the step to be energized.
Single-step capacitor bank scheme
Use the A/AF... contactor ranges.
E1179D
E1178D
Multi-step capacitor bank scheme
Use the UA... or UA..RA contactor ranges.
Steady state condition data
The presence of harmonics and the network's voltage tolerance lead to a current, estimated to be 1.3 times the nominal current In of the capacitor, permanently circulating in the circuit.
Taking into account the manufacturing tolerances, the exact power of a capacitor can reach 1.15 times its nominal power.
Standard IEC 60831-1 Edition 2002 specifies that the capacitor must therefore have a maximum thermal current IT of:
IT = 1.3 x 1.15 x In = 1.5 x In
Consequences for the contactors
To avoid malfunctions (welding of main poles, abnormal temperature rise, etc.), contactors for capacitor bank switching must be sized to withstand:
–– A permanent current that can reach 1.5 times the nominal current of the capacitor bank.
–– The short but high peak current on pole closing (maximum permissible peak current Î ).
Contactor selection tool for capacitor switching
In a given application, if the user does not know the value of the inrush current peak,
this value can be approximately calculated using the formulas given on the pages
"Calculation and dimensioning".
Alternatively by the CAPCAL selection tool, available on the ABB Website:
www.abb.com/lowvoltage
right hand side menu
search: "Online product selection tools"
select: "Contactors: AC-6b capacitor switching"
This program allows the calculation of these peaks and gives the references of the
ABB contactors according to the installation specifications. This calculation is valid for
one or several capacitor banks.
5/264 | ABB
1SBC101603S0201
5
The inrush current peak, in the case of fixed correction, can reach 30
times the nominal current of the capacitor bank.
An automatic power factor correction system, on the other hand,
consists of several capacitor banks of identical or different ratings
(several steps), energized separately according to the value of the
power factor to be corrected.
Contactors for capacitor switching
The ABB solutions
ABB offers 2 contactor versions according to the value of the inrush current peak and the power of the capacitor bank.
UA..RA contactors for capacitor switching (UA16..RA to UA110..RA) with insertion of damping resistors
1SBC587764F0301
1SBC587774F0301
1SBC587794F0301
1SBC591444F0302
The insertion of damping resistors protects the contactor and the capacitor from the highest inrush currents.
5
UA contactors for capacitor switching (UA16 to UA110)
1SBC101604S0201 - Rev. A
1SBC580105F0303
1SBC580783F0303
1SBC580093F0303
1SBC591694F0303
Maximum permissible peak current Î ≤ 100 times the nominal rms current of the switched capacitor.
ABB | 5/265
UA16..RA … UA30..RA 3-pole contactors for capacitor switching
12.5 to 30 kvar - Unlimited peak current Î
AC operated
Description
UA..RA contactors for capacitor switching can be used for installations in which the peak current far
exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors
and must be used without additional inductances.
1SBC587794F0301
The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
These contactors are of the block type design with:
–– 3 main poles and 1 built-in auxiliary contact
–– the UA..RA contactors are fitted with a special front-mounted block, which ensures the serial insertion of 3
damping resistors into the circuit to limit the current peak on energization of the capacitor bank
-- their connection also ensures capacitor precharging in order to limit the second current peak occurring
upon making of the main poles
-- the insertion of resistors allows to damp the highest current peak of the capacitor when switching on,
whatever its level.
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
UA16-30-10RA
5
1SBC587774F0301
Ordering details
IEC
Rated operational
power
θ ≤ 40 °C
400 V
AC-6b
kvar
12.5
UL/CSA
Rated operational
power
θ ≤ 40 °C
480 V
Rated control circuit
voltage
Uc
(1)
kvar
16
22
22
30
28
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
UA30-30-10RA
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
Auxiliary Type
contacts
fitted
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Order code
Weight
Pkg
(1 pce)
UA16-30-10RA
UA16-30-10RA
UA16-30-10RA
UA16-30-10RA
UA16-30-10RA
UA16-30-10RA
UA16-30-10RA
UA26-30-10RA
UA26-30-10RA
UA26-30-10RA
UA26-30-10RA
UA26-30-10RA
UA26-30-10RA
UA26-30-10RA
UA30-30-10RA
UA30-30-10RA
UA30-30-10RA
UA30-30-10RA
UA30-30-10RA
UA30-30-10RA
UA30-30-10RA
kg
0.460
0.460
0.460
0.460
0.460
0.460
0.460
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.810
0.810
0.810
0.810
0.810
0.810
0.810
1SBL181024R8110
1SBL181024R8310
1SBL181024R8410
1SBL181024R8010
1SBL181024R8810
1SBL181024R8510
1SBL181024R8610
1SBL241024R8110
1SBL241024R8310
1SBL241024R8410
1SBL241024R8010
1SBL241024R8810
1SBL241024R8510
1SBL241024R8610
1SBL281024R8110
1SBL281024R8310
1SBL281024R8410
1SBL281024R8010
1SBL281024R8810
1SBL281024R8510
1SBL281024R8610
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
126.3 4.97"
141 5.55"
87.3 3.44"
107 4.21"
68 2.68"
102 4.02"
9 0.35"
9 0.35"
UA16..RA
5/266 | ABB
UA26..RA
54 2.13"
UA30..RA
+.394"
47 1.85"
130 +10 5.12"
35 mm EN/IEC 60715
90 3.54"
4.72" +.394"
47 1.85"
120
4 0.16"
4 0.16"
54 2.13"
1SBC101507S0201
4 0.16"
44 1.73"
+10
35 mm EN/IEC 60715
90 3.54"
47 1.85"
120 +10 4.72" +.394"
74 2.91"
35 mm EN/IEC 60715
5.5 0.22"
UA50..RA … UA75..RA 3-pole contactors for capacitor switching
40 to 60 kvar - Unlimited peak current Î
AC operated
Description
These contactors are of the block type design with:
–– 3 main poles
–– the UA..RA contactors are fitted with a special front-mounted block, which ensures the serial insertion of 3
damping resistors into the circuit to limit the current peak on energization of the capacitor bank
-- their connection also ensures capacitor precharging in order to limit the second current peak occurring
upon making of the main poles
-- the insertion of resistors allows to damp the highest current peak of the capacitor when switching on,
whatever its level.
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
5
Ordering details
IEC
Rated operational
power
θ ≤ 40 °C
400 V
AC-6b
kvar
40
UL/CSA
Rated operational
power
θ ≤ 40 °C
480 V
Rated control circuit
voltage
Uc
(1)
kvar
50
50
55
60
64
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Auxiliary Type
contacts
fitted
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
UA50-30-00RA
UA50-30-00RA
UA50-30-00RA
UA50-30-00RA
UA50-30-00RA
UA50-30-00RA
UA50-30-00RA
UA63-30-00RA
UA63-30-00RA
UA63-30-00RA
UA63-30-00RA
UA63-30-00RA
UA63-30-00RA
UA63-30-00RA
UA75-30-00RA
UA75-30-00RA
UA75-30-00RA
UA75-30-00RA
UA75-30-00RA
UA75-30-00RA
UA75-30-00RA
Order code
Weight
Pkg
(1 pce)
1SBL351024R8100
1SBL351024R8300
1SBL351024R8400
1SBL351024R8000
1SBL351024R8800
1SBL351024R8500
1SBL351024R8600
1SBL371024R8100
1SBL371024R8300
1SBL371024R8400
1SBL371024R8000
1SBL371024R8800
1SBL371024R8500
1SBL371024R8600
1SBL411024R8100
1SBL411024R8300
1SBL411024R8400
1SBL411024R8000
1SBL411024R8800
1SBL411024R8500
1SBL411024R8600
kg
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
1.350
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
101.5 4"
+10
1SBC101508S0201
150
75 mm EN/IEC 60715
4 0.16"
5.91" +10"
10 0.39"
47 1.85"
35 mm x 15 EN/IEC 60715
140.4 5.53"
114 4.49"
UA75-30-00 RA
The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
110 4.33"
1SBC587764F0301
UA..RA contactors for capacitor switching can be used for installations in which the peak current far
exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors
and must be used without additional inductances.
6 0.24"
70 2.76"
UA50..RA, UA63..RA, UA75..RA
ABB | 5/267
UA95..RA … UA110..RA 3-pole contactors for capacitor switching
70 to 80 kvar - Unlimited peak current Î
AC operated
Description
1SBC591444F0302
UA..RA contactors for capacitor switching can be used for installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors
and must be used without additional inductances.
UA110-30-00 RA
5
The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making.
These contactors are of the block type design with:
–– 3 main poles
–– the UA..RA contactors are fitted with a special front-mounted block, which ensures the serial insertion of
3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank
-- their connection also ensures capacitor precharging in order to limit the second current peak occurring
upon making of the main poles
-- the insertion of resistors allows to damp the highest current peak of the capacitor when switching on,
whatever its level.
–– control circuit: AC operated
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
IEC
Rated operational
power
θ ≤ 40 °C
400 V
AC-6b
70
UL/CSA
Rated operational
power
θ ≤ 40 °C
480 V
80
95
80
Rated control circuit
voltage
Uc
(1)
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Auxiliary Type
contacts
fitted
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
UA95-30-00RA
UA95-30-00RA
UA95-30-00RA
UA95-30-00RA
UA95-30-00RA
UA95-30-00RA
UA95-30-00RA
UA110-30-00RA
UA110-30-00RA
UA110-30-00RA
UA110-30-00RA
UA110-30-00RA
UA110-30-00RA
UA110-30-00RA
Order code
Weight
Pkg
(1 pce)
1SFL431024R8100
1SFL431024R8300
1SFL431024R8400
1SFL431024R8000
1SFL431024R8800
1SFL431024R8500
1SFL431024R8600
1SFL451024R8100
1SFL451024R8300
1SFL451024R8400
1SFL451024R8000
1SFL451024R8800
1SFL451024R8500
1SFL451024R8600
kg
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
155.6 6.13"
10 0.39"
90 3.54"
UA95..RA, UA100..RA
5/268 | ABB
1SBC101553S0201
47 1.85"
75 mm EN/IEC 60715
148 5.83"
155.3 6.11"
6 0.24"
170 +10 6.69" +10"
114.4 4.5"
UA..RA 3-pole contactors for capacitor switching
Unlimited peak current Î
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Main
poles
Available Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
UA16-30-10RA
UA26-30-10RA
UA30-30-10RA
UA50-30-00RA
UA63-30-00RA
UA75-30-00RA
UA95-30-00RA
UA110-30-00RA
3
3
3
3
3
3
3
3
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Side-mounted accessories
Auxiliary contact blocks
1-pole CA5-..
2-pole CAL...
–
1 x CA5-...
1 to 2 x CA5-...
+
+
1
1
1
1
1 to 2 x CA5-...
+
1 to 2 x CAL18-11
–
x CAL5-11
to 2 x CAL5-11
to 2 x CAL5-11
to 2 x CAL5-11
5
1SBC101509S0201
Contactor
types
ABB | 5/269
UA16..RA … UA110..RA 3-pole contactors for capacitor switching
Unlimited peak current Î
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
AC-6b Utilization category
Rated operational power AC-6b
For air temperature close
θ ≤ 40 °C
to contactor
AC operated
230-240 V
400-415 V
440 V
500-550 V
690 V
230-240 V
400-415 V
440 V
500-550 V
690 V
230-240 V
400-415 V
440 V
500-550 V
690 V
θ ≤ 55 °C
Multi-step capacitor
bank scheme
θ ≤ 70 °C
Max. permissible peak current Î
Short-circuit protection device for contactors
UA75..RA
UA95..RA
UA110..RA
8 kvar
12.5 kvar
15 kvar
18 kvar
22 kvar
7.5 kvar
12.5 kvar
13 kvar
16 kvar
21 kvar
6 kvar
10 kvar
11 kvar
12.5 kvar
17 kvar
Unlimited
35 kvar
60 kvar
65 kvar
75 kvar
100 kvar
30 kvar
50 kvar
53 kvar
65 kvar
80 kvar
25 kvar
41 kvar
45 kvar
55 kvar
70 kvar
40 kvar
70 kvar
75 kvar
85 kvar
120 kvar
35 kvar
60 kvar
65 kvar
75 kvar
105 kvar
30 kvar
53 kvar
58 kvar
70 kvar
85 kvar
45 kvar
80 kvar
85 kvar
95 kvar
130 kvar
40 kvar
70 kvar
75 kvar
82 kvar
110 kvar
35 kvar
60 kvar
70 kvar
78 kvar
100 kvar
12.5 kvar
22 kvar
24 kvar
30 kvar
35 kvar
11.5 kvar
20 kvar
20 kvar
25 kvar
31 kvar
9 kvar
15.5 kvar
17 kvar
20 kvar
26 kvar
16 kvar
30 kvar
32 kvar
34 kvar
45 kvar
16 kvar
27.5 kvar
30 kvar
34 kvar
45 kvar
11 kvar
19.5 kvar
20.5 kvar
25 kvar
32 kvar
25
40
50
55
72
24
40
43
50
65
20
35
37
46
60
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
kvar
30 kvar
50 kvar
55 kvar
65 kvar
80 kvar
27 kvar
45 kvar
48 kvar
60 kvar
75 kvar
23 kvar
39 kvar
42.5 kvar
50 kvar
65 kvar
80 A
125 A
200 A
240 cycles/h
Ue ≤ 440 V 250 000 operating cycles
500 V ≤ Ue ≤ 690 V 100 000 operating cycles
gG type fuse (1)
Max. electrical switching frequency
Electrical durability AC-6b
250 A
(1) The fuse ratings given represent the maximum ratings ensuring type 1 coordination according to the definition of standard IEC 60947-4-1.
Main pole - Utilization characteristics according to UL / CSA
Contactor types
Power - 60 Hz
For air temperature close
to contactor
AC operated
UA16..RA
UA26..RA
UA30..RA
UA50..RA
UA63..RA
UA75..RA
UA95..RA
UA110..RA
240 V
480 V
600 V
8 kvar
16 kvar
20 kvar
Unlimited
11 kvar
22 kvar
27 kvar
14 kvar
28 kvar
35 kvar
25 kvar
50 kvar
62 kvar
27.5 kvar
55 kvar
70 kvar
32 kvar
64 kvar
80 kvar
40 kvar
80 kvar
100 kvar
45 kvar
95 kvar
120 kvar
θ ≤ 40 °C
Max. permissible peak Current Î
Operating principle
The front-mounted block mechanism of the UA..RA contactors ensures:
–– early making of the auxiliary "PA" poles with respect to the main "PP" poles
–– automatic return to the open position of the auxiliary "PA" poles after the main poles are closed.
When the coil is energized, the early making auxiliary poles connect the capacitor to the network via the set of 3 resistors. The damping
resistors attenuate the first current peak and the second inrush current when the main contacts begin to make. Once the main poles are in the
closed position, the auxiliary poles automatically break.
When the coil is de-energized, the main poles break ensuring the breaking of the capacitor bank.
The contactor can then begin a new cycle.
Coil voltage
Uc
R
A1
PP
A2
PA
R
C
Aux. poles
PA
Main poles
PP
Total
closing time
The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level.
5/270 | ABB
1SBC101510S0201
5
UA16..RA UA26..RA UA30..RA UA50..RA UA63..RA
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
UA16..RA … UA110..RA 3-pole contactors for capacitor switching
Unlimited peak current Î
Technical data
Connecting characteristics
Contactor types
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with ferrule
l L
Bars or lugs
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with ferrule
l L
UA16..RA
UA26..RA
UA30..RA
UA50..RA
UA63..RA
UA75..RA
UA95..RA
UA110..RA
1x
2x
1x
2x
L≤
l>
1 or 2 x
1...4 mm²
0.75...2.5 mm²
7.7 mm
3.7 mm
AWG 18...10
1 Nm / 9 Ib.in
1.2 Nm
1.5...6 mm²
1.5...4 mm²
10 mm
4.2 mm
AWG 12...8
1.7 Nm / 15 Ib.in
2.2 Nm
2.5...16 mm²
2.5...16 + 2.5...6 mm²
2.5...10 mm²
2.5...10 + 2.5...4 mm²
AWG 8...4
2.3 Nm / 20 Ib.in
2.6 Nm
6...50 mm²
6…25 + 6…16 mm²
6...35 mm²
6...16 + 6...10 mm²
AWG 8...1
4 Nm / 35 Ib.in
4.5 Nm
10...95 mm²
6...35 mm²
10...70 mm²
6...35 mm²
AWG 6...2/0
8 Nm / 53 Ib.in
9 Nm
1x
2x
1x
2x
L≤
l>
L≤
l>
1 or 2 x
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.7 mm
7.7 mm
3.7 mm
AWG 18...14
1…2.5 mm²
0.75…2.5 mm²
0.75…2.5 mm²
0.75…2.5 mm²
-
-
AC operated
Lugs
Coil terminals
Built-in auxiliary
terminals
Connection capacity acc. to UL/CSA
Tightening torque
Coil terminals
Recommended
Max.
Built-in auxiliary terminals Recommended
Max.
Degree of protection
10 mm
4.2 mm
8 mm
3.7 mm
5
1 Nm / 9 Ib.in
1.2 Nm
1 Nm / 9 Ib.in
1.2 Nm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Built-in auxiliary terminals
Screw terminals
Main terminals
Coil terminals
IP20
IP10
IP20
IP20
Delivered in open position, screws of unused terminals must be tightened
M 3.5
M4
M5
M6
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Flat Ø 6.5 / Pozidriv 2
M 3.5
Flat Ø 5.5 / Pozidriv 2
M 3.5
M4
Screwdriver type Flat Ø 5.5 / Pozidriv 2
M8
Hexagon socket
(s = 4 mm)
Screwdriver type
Built-in auxiliary terminals
M 3.5
-
-
1SBC101513S0201
Other technical characteristics are the same as those of standard A contactors.
ABB | 5/271
UA..RA contactors
Terminal marking and positioning
UA..RA contactors - AC operated
Standard devices without addition of auxiliary contacts
A2
A1
A1
1L1 3L2 5L3 13
27
37
NO
47
27
37
NO
47 5-
NO
NO
NO
NO
NO
NO
28
38
48
NO
28
38
48 5NO
2T1 4T2 6T3 14
A2
1-
A1
3L2
27
37
47
NO
NO
28
38
48
14
A2
27 37 47
NO NO NO
28 38 48
2T1 4T2 6T3 14
UA30-30-10 RA
2T1 4T2 6T3
UA16 ... 30-30-10 RA
1L1 3L2 5L3
5L3
NO
13
NO
A2
A1
1L1
1L1 3L2 5L3
A2
UA16-30-10 RA
UA26-30-10 RA
5-
A1
27 37 47
NO NO NO
1-
2T1
4T2
5-
28 38 48
A2
6T3
A2
UA50 ... 110-30-00 RA
2T1 4T2 6T3
UA50 ... 110-30-00 RA
1SBC101574S0201
5
A2
1L1 3L2 5L3 13
5/272 | ABB
UA..RA 3-pole contactors for capacitor switching
Unlimited peak current Î
Main dimensions
mm, inches
107 4.21"
68 2.68"
ø 4.5 0.18"
M4 8-32 UNC
60 2.36"
50 1.97"
47 1.85"
120 +10 4.72" +.394"
35 1.38"
35 mm EN/IEC 60715
74 2.91"
5.5 0.22"
4 0.16"
44 1.73"
4.5
0.18"
4.5
0.18"
UA16..RA
5
126.3 4.97"
87.3 3.44"
45 1.77"
ø 4.2 0.17"
M4 8-32 UNC
4 0.16"
80 3.15"
120
54 2.13"
70 2.76"
4.72"
+.394"
47 1.85"
+10
35 mm EN/IEC 60715
90 3.54"
9 0.35"
4.5
0.18"
4.5
0.18"
UA26..RA
141 5.55"
102 4.02"
ø 4.2 0.17"
M4 8-32 UNC
80 3.15"
4 0.16"
54 2.13"
70 2.76"
47 1.85"
130 +10 5.12"
+.394"
45 1.77"
35 mm EN/IEC 60715
90 3.54"
9 0.35"
4.5
0.18"
4.5
0.18"
UA30..RA
10 0.39"
5
0.2"
60 2.36"
1SBC101575S0201
100 3.94"
150
6 0.24"
90 3.54"
5.91"
+10"
+10
75 mm EN/IEC 60715
4 0.16"
70 2.76"
ø 6.2 0.24"
M6 1/4-20 UNC
47 1.85"
35 mm x 15 EN/IEC 60715
114 4.49"
110 4.33"
140.4 5.53"
101.5 4"
5
0.2"
UA50..RA, UA63..RA, UA75..RA
ABB | 5/273
UA..RA 3-pole contactors for capacitor switching
Unlimited peak current Î
Main dimensions
mm, inches
155.6 6.13"
90 3.54"
136 5.35"
126 4.96"
170 +10 6.69" +10"
47 1.85"
10 0.39"
ø 6.2 0.24"
M6 1/4-20 UNC
6 0.24"
6 0.24"
UA95..RA, UA110..RA
1SBC101575S0201
5
78 3.07"
6 0.24"
75 mm EN/IEC 60715
148 5.83"
155.3 6.11"
114.4 4.5"
5/274 | ABB
Notes
N7
5
ABB | 5/275
UA16 … UA30 3-pole contactors for capacitor switching
12.5 to 27.5 kvar - peak current Î ≤ 100 times the rms current
AC operated
Description
UA contactors can be used for the switching of capacitor banks whose inrush current peaks are less than or
equal to 100 times nominal rms current.
1SBC591694F0304
The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
These contactors are of the block type design with:
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
UA16-30-10
Ordering details
1SBC580093F0303
5
IEC
Rated
operational
power
θ ≤ 40 °C
400 V
AC-6b
kvar
12.5
UL/CSA
Rated
operational
power
θ ≤ 40 °C
480 V
Rated control circuit
voltage
Uc
(1)
Î
kA
1.8
kvar
-
20
3
25
27.5
3.5
32
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Max
peak
current
UA30-30-10
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
Auxiliary Type
contacts
fitted
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Order code
Weight
Pkg
(1 pce)
UA16-30-10
UA16-30-10
UA16-30-10
UA16-30-10
UA16-30-10
UA16-30-10
UA16-30-10
UA26-30-10
UA26-30-10
UA26-30-10
UA26-30-10
UA26-30-10
UA26-30-10
UA26-30-10
UA30-30-10
UA30-30-10
UA30-30-10
UA30-30-10
UA30-30-10
UA30-30-10
UA30-30-10
1SBL181022R8110
1SBL181022R8310
1SBL181022R8410
1SBL181022R8010
1SBL181022R8810
1SBL181022R8510
1SBL181022R8610
1SBL241022R8110
1SBL241022R8310
1SBL241022R8410
1SBL241022R8010
1SBL241022R8810
1SBL241022R8510
1SBL241022R8610
1SBL281022R8110
1SBL281022R8310
1SBL281022R8410
1SBL281022R8010
1SBL281022R8810
1SBL281022R8510
1SBL281022R8610
kg
0.340
0.340
0.340
0.340
0.340
0.340
0.340
0.600
0.600
0.600
0.600
0.600
0.600
0.600
0.710
0.710
0.710
0.710
0.710
0.710
0.710
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
93.6 3.69"
74 2.91"
9 0.35"
68 2.68"
6.3 0.25"
44 1.73"
35 mm EN/IEC 60715
90 3.54"
74 2.91"
35 mm EN/IEC 60715
5.5 0.22"
4
0.16"
10
0.39"
54 2.13"
UA16
4 0.16"
10 0.39"
UA26
108.3 4.26"
UA30
4 0.16"
10 0.39"
1SBC101514S0201
90 3.54"
54 2.13"
5/276 | ABB
6.3 0.25"
35 mm EN/IEC 60715
9 0.35"
UA50 … UA75 3-pole contactors for capacitor switching
33 to 50 kvar - peak current Î ≤ 100 times the rms current
AC operated
Description
These contactors are of the block type design with:
–– 3 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
IEC
Rated
operational
power
θ ≤ 40 °C
400 V
AC-6b
kvar
33
UL/CSA
Rated
operational
power
θ ≤ 40 °C
480 V
Rated control circuit
voltage
Uc
(1)
Î
kA
5
kvar
40
45
6.5
-
50
7.5
55
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Max
peak
current
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
Auxiliary Type
contacts
fitted
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
UA50-30-00
UA50-30-00
UA50-30-00
UA50-30-00
UA50-30-00
UA50-30-00
UA50-30-00
UA63-30-00
UA63-30-00
UA63-30-00
UA63-30-00
UA63-30-00
UA63-30-00
UA63-30-00
UA75-30-00
UA75-30-00
UA75-30-00
UA75-30-00
UA75-30-00
UA75-30-00
UA75-30-00
Order code
Weight
Pkg
(1 pce)
1SBL351022R8100
1SBL351022R8300
1SBL351022R8400
1SBL351022R8000
1SBL351022R8800
1SBL351022R8500
1SBL351022R8600
1SBL371022R8100
1SBL371022R8300
1SBL371022R8400
1SBL371022R8000
1SBL371022R8800
1SBL371022R8500
1SBL371022R8600
1SBL411022R8100
1SBL411022R8300
1SBL411022R8400
1SBL411022R8000
1SBL411022R8800
1SBL411022R8500
1SBL411022R8600
5
kg
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
1.160
(1) Other control voltages see voltage code table.
mm, inches
35 mm x15 EN/IEC 60715
Main dimensions
108 4.25"
6 0.24"
6.5 0.26"
70 2.76"
10 0.39"
1SBC101521S0201
4
0.16"
75 mm EN/IEC 60715
UA50-30-00
The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
110 4.33"
1SBC580783F0303
UA contactors can be used for the switching of capacitor banks whose inrush current peaks are less than or
equal to 100 times nominal rms current.
10 0.39"
UA50, UA63, UA75
ABB | 5/277
UA50 … UA75 3-pole contactors for capacitor switching
33 to 50 kvar - Peak current Î < 100 Times the rms current
AC operated - with 1 N.O. + 1 N.C. auxiliary contacts
Description
UA contactors can be used for the switching of capacitor banks whose inrush current peaks are less than or
equal to 100 times nominal rms current.
1SBC101381F0014
The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
UA50-30-11
These contactors are of the block type design with:
–– 3 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
IEC
Rated
operational
power
θ ≤ 40 °C
400 V
AC-6b
kvar
33
5
UL/CSA
Rated
operational
power
θ ≤ 40 °C
400 V
Rated control circuit
voltage
Uc
(1)
Î
kA
5
kvar
40
45
6.5
-
50
7.5
55
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Max
peak
current
Auxiliary Type
contacts
fitted
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
UA50-30-11
UA50-30-11
UA50-30-11
UA50-30-11
UA50-30-11
UA50-30-11
UA50-30-11
UA63-30-11
UA63-30-11
UA63-30-11
UA63-30-11
UA63-30-11
UA63-30-11
UA63-30-11
UA75-30-11
UA75-30-11
UA75-30-11
UA75-30-11
UA75-30-11
UA75-30-11
UA75-30-11
Order code
Weight
Pkg
(1 pce)
1SBL351022R8111
1SBL351022R8311
1SBL351022R8411
1SBL351022R8011
1SBL351022R8811
1SBL351022R8511
1SBL351022R8611
1SBL371022R8111
1SBL371022R8311
1SBL371022R8411
1SBL371022R8011
1SBL371022R8811
1SBL371022R8511
1SBL371022R8611
1SBL411022R8111
1SBL411022R8311
1SBL411022R8411
1SBL411022R8011
1SBL411022R8811
1SBL411022R8511
1SBL411022R8611
kg
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
1.200
(1) Other control voltages see voltage code table.
35 mm x15 EN/IEC 60715
6.5 0.26"
10 0.39"
10 0.39"
UA50, UA63, UA75 with 1 N.O. + 1 N.C. auxiliary contacts
5/278 | ABB
1SBC101529S0201
70 2.76"
108 4.25"
6 0.24"
4
0.16"
75 mm EN/IEC 60715
74 2.91"
12
0.47"
mm, inches
110 4.33"
Main dimensions
UA95 ... UA110 3-pole contactors for capacitor switching
65 to 75 kvar - peak current Î ≤ 100 times the rms current
AC operated
Description
Ordering details
IEC
Rated
operational
power
θ ≤ 40 °C
400 V
AC-6b
kvar
65
75
UL/CSA
Rated
operational
power
θ ≤ 40 °C
480 V
Rated control circuit
voltage
Uc
(1)
Î
kA
9.3
kvar
70
10.5
80
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Max
peak
current
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
Auxiliary Type
contacts
fitted
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
UA95-30-00
UA95-30-00
UA95-30-00
UA95-30-00
UA95-30-00
UA95-30-00
UA95-30-00
UA110-30-00
UA110-30-00
UA110-30-00
UA110-30-00
UA110-30-00
UA110-30-00
UA110-30-00
Order code
Weight
Pkg
(1 pce)
1SFL431022R8100
1SFL431022R8300
1SFL431022R8400
1SFL431022R8000
1SFL431022R8800
1SFL431022R8500
1SFL431022R8600
1SFL451022R8100
1SFL451022R8300
1SFL451022R8400
1SFL451022R8000
1SFL451022R8800
1SFL451022R8500
1SFL451022R8600
5
kg
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
2.000
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
123.5 4.86"
6.5 0.26"
6 0.24"
1SFC101059C0201
20 0.79"
10 0.39"
E0784D1
90 3.54"
E0783D
UA110-30-00
These contactors are of the block type design with:
–– 3 main poles
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
148 5.83"
1SBC580105F0303
UA contactors can be used for the switching of capacitor banks whose inrush current peaks are less or
equal to 100 times nominal rms current.
The capacitors must be discharges (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
UA95, UA110
ABB | 5/279
UA95 ... UA110 3-pole contactors for capacitor switching
65 to 75 kvar - peak current Î < 100 times the rms current
AC operated with 1 N.O. + 1 N.C. auxiliary contacts
1SBC580105F0303
Description
UA110-30-11
UA contactors can be used for the switching of capacitor banks whose inrush current peaks are less or
equal to 100 times nominal rms current.
The capacitors must be discharges (maximum residual voltage at terminals ≤ 50 V) before being re-energized
when the contactors are making.
These contactors are of the block type design with:
- 3 main poles
- control circuit: AC operated
- add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
Ordering details
IEC
Rated
operational
power
AC-6b
θ ≤ 40 °C
400 V
kvar
65
5
75
Max
peak
current
UL/CSA
Rated
operational
power
Î
kA
9.3
40 °C
400 V
kvar
70
10.5
80
Rated control circuit
voltage
Uc
(1)
V 50 Hz
24
48
110
220…230
230…240
380…400
400…415
24
48
110
220…230
230…240
380…400
400…415
Auxiliary Type
contacts
fitted
V 60 Hz
24
48
110…120
230…240
240…260
400…415
415…440
24
48
110…120
230…240
240…260
400…415
415…440
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
UA95-30-11
UA95-30-11
UA95-30-11
UA95-30-11
UA95-30-11
UA95-30-11
UA95-30-11
UA110-30-11
UA110-30-11
UA110-30-11
UA110-30-11
UA110-30-11
UA110-30-11
UA110-30-11
Order code
Weight
Pkg
(1 pce)
1SFL431022R8111
1SFL431022R8311
1SFL431022R8411
1SFL431022R8011
1SFL431022R8811
1SFL431022R8511
1SFL431022R8611
1SFL451022R8111
1SFL451022R8311
1SFL451022R8411
1SFL451022R8011
1SFL451022R8811
1SFL451022R8511
1SFL451022R8611
kg
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
2.040
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
123.5 4.86"
6.5 0.26"
5/280 | ABB
20
0.79"
E0788D1
10 0.39"
1SFC101060C0201
UA95, UA110
148 5.83"
90 3.54"
E0787D
74 2.91"
12 0.47"
6 0.24"
UA... 3-pole contactors for capacitor switching
Peak current Î ≤ 100 times the rms current
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Main
poles
Available Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
UA16-30-10
UA26-30-10
UA30-30-10
3 0
3 0
3 0
1 0
1 0
1 0
1 to 4 x CA5-..
1 to 4 x CA5-..
1 to 5 x CA5-..
or 1 x CA5-.. (4-pole)
or 1 x CA5-.. (4-pole)
or 1 x CA5-.. (4-pole)
UA50-30-00
UA63-30-00
UA75-30-00
UA95-30-00
UA110-30-00
3
3
3
3
3
0
0
0
0
0
1 to 6 x CA5-..
or 1 x CA5-.. (4-pole)
4-pole CA5-..
+ 1 x 1-pole CA5-..
0
0
0
0
0
0
0
0
0
0
+ 2 x 1-pole CA5-..
1 to 6 x CA5-..
or 1 x CA5-.. (4-pole)
TP.. A
or 1 x TP.. A
or 1 x TP.. A
or 1 x TP.. A
2-pole CAL...
+
+
+
1 to 2 x CAL5-11
1 to 2 x CAL5-11
1 to 2 x CAL5-11
+
1 to 2 x CAL5-11
+
1 to 2 x CAL18-11
+ 1 x CA5-.. (1-pole)
or 1 x TP.. A
+ 2 x CA5-.. (1-pole)
–
5
+ 2 x 1-pole CA5-..
1SBC101533S0201
1-pole CA5-..
Side-mounted accessories
Auxiliary contact
blocks
Pneumatic timer
ABB | 5/281
UA16 … UA110 3-pole contactors for capacitor switching
Peak current Î ≤ 100 times the rms current
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
AC-6b Utilization category
Rated operational power AC-6b (1)
For air temperature close
θ ≤ 40 °C
to contactor
θ ≤ 55 °C
Multi-step capacitor
bank scheme
θ ≤ 70 °C
Max. permissible peak current Î
230-240 V
400-415 V
440 V
500-550 V
690 V
230-240 V
400-415 V
440 V
500-550 V
690 V
230-240 V
400-415 V
440 V
500-550 V
690 V
Ue ≤ 500 V
Ue > 500 V
UA16
UA26
UA30
UA50
UA63
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
UA75
UA95
UA110
7.5 kvar
12.5 kvar
13.7 kvar
15.5 kvar
21.5 kvar
6.7 kvar
11.7 kvar
13 kvar
14.7 kvar
20 kvar
6 kvar
10 kvar
11 kvar
12.5 kvar
17 kvar
1.8 kA
1.6 kA
30 kvar
50 kvar
55 kvar
62 kvar
75 kvar
30 kvar
50 kvar
53 kvar
62 kvar
75 kvar
22 kvar
39 kvar
43 kvar
47.5 kvar
65 kvar
7.5 kA
6.75 kA
35 kvar
65 kvar
65 kvar
70 kvar
80 kvar
35 kvar
65 kvar
65 kvar
70 kvar
80 kvar
30 kvar
55 kvar
55 kvar
60 kvar
70 kvar
9.3 kA
8 kA
40 kvar
75 kvar
75 kvar
80 kvar
90 kvar
40 kvar
70 kvar
75 kvar
80 kvar
90 kvar
35 kvar
65 kvar
70 kvar
75 kvar
85 kvar
10.5 kA
9 kA
12 kvar
20 kvar
22 kvar
22 kvar
30 kvar
11 kvar
18.5 kvar
20 kvar
22 kvar
30 kvar
8.5 kvar
14.5 kvar
16 kvar
19.5 kvar
25 kvar
3 kA
2.7 kA
16 kvar
27.5 kvar
30 kvar
34 kvar
45 kvar
16 kvar
27.5 kvar
30 kvar
34 kvar
45 kvar
11 kvar
19 kvar
20 kvar
23.5 kvar
32 kvar
3.5 kA
3.1 kA
20 kvar
33 kvar
36 kvar
40 kvar
55 kvar
20 kvar
33 kvar
36 kvar
40 kvar
55 kvar
19 kvar
32 kvar
35 kvar
40 kvar
52 kvar
5 kA
4.5 kA
25 kvar
45 kvar
50 kvar
50 kvar
70 kvar
25 kvar
43 kvar
48 kvar
50 kvar
70 kvar
21 kvar
37 kvar
41 kvar
45 kvar
60 kvar
6.5 kA
5.8 kA
Short-circuit protection device for contactors
gG type fuse
Max. electrical switching frequency
Electrical durability AC-6b
sized 1.5…1.8 In of the capacitor
240 cycles/h
Ue ≤ 690 V 100 000 operating cycles
(1) For 220 V and 380 V, multiply by 0.9 the rated values at 230 V and 400 V respectively.
Example: 50 kvar / 400 V corresponding to 0.9 x 50 = 45 kvar/380 V.
If, in an application, the current peak is greater than the maximum peak current Î specified in the tables above, select a higher rating, refer to the UA..RA contactors, or add inductances. (see application guide "Contactors for capacitor switching").
Main pole - Utilization characteristics according to UL / CSA
Contactor types
Power - 60 Hz
For air temperature close
to contactor
AC operated
θ ≤ 40 °C
240 V
480 V
600 V
UA16
UA26
UA30
UA50
UA63
UA75
UA95
UA110
-
12.5 kvar
25 kvar
30 kvar
16 kvar
32 kvar
40 kvar
20 kvar
40 kvar
50 kvar
-
27.5 kvar
55 kvar
70 kvar
35 kvar
70 kvar
75 kvar
40 kvar
80 kvar
85 kvar
If, in an application, the current peak is greater than the maximum peak current Î specified in the tables above, select a higher rating, refer to the UA..RA contactors, or add inductances. (see application guide "Contactors for capacitor switching").
1SBC101536S0201
5
AC operated
5/282 | ABB
UA16 … UA110 3-pole contactors for capacitor switching
Peak current Î ≤ 100 times the rms current
Technical data
Connecting characteristics
Contactor types
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with ferrule
l L
Bars or lugs
Connection capacity acc. to UL/CSA
Tightening torque
Recommended
Max.
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with ferrule
l L
UA16
UA26
UA30
UA50
UA63
UA75
UA95
UA110
1x
2x
1x
2x
L≤
l>
1 or 2 x
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
7.7 mm
3.7 mm
AWG 18...10
1 Nm / 9 Ib.in
1.2 Nm
1.5...6 mm²
1.5...6 mm²
0.75...4 mm²
0.75...4 mm²
10 mm
4.2 mm
AWG 12...8
1.7 Nm / 15 Ib.in
2.2 Nm
2.5...16 mm²
2.5...16 mm²
2.5...10 mm²
2.5...10 mm²
AWG 8...4
2.3 Nm / 20 Ib.in
2.6 Nm
6...50 mm²
6...25 mm²
6...35 mm²
6...16 mm²
AWG 8...1
4 Nm / 35 Ib.in
4.5 Nm
10...95 mm²
6...35 mm²
10...70 mm²
6...35 mm²
AWG 6...2/0
8 Nm / 71 Ib.in
9 Nm
1x
2x
1x
2x
L≤
l>
L≤
l>
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.7 mm
7.7 mm
3.7 mm
AWG 18...14
1…2.5 mm²
0.75…2.5 mm²
0.75…2.5 mm²
0.75…2.5 mm²
-
-
AC operated
Lugs
Coil terminals
Built-in auxiliary
terminals
Connection capacity acc. to UL/CSA
Tightening torque
Coil terminals
Recommended
Max.
Built-in auxiliary terminals Recommended
Max.
Degree of protection
10 mm
4.2 mm
8 mm
3.7 mm
5
1 Nm / 9 Ib.in
1.2 Nm
1 Nm / 9 Ib.in
1.2 Nm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals
Coil terminals
Built-in auxiliary terminals
Screw terminals
Main terminals
Coil terminals
IP20
IP10
IP20
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
M4
M5
M6
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Flat Ø 6.5 / Pozidriv 2
M3.5
Flat Ø 5.5 / Pozidriv 2
M3.5
M4
Screwdriver type Flat Ø 5.5 / Pozidriv 2
M8
Hexagon socket
(s = 4 mm)
Screwdriver type
Built-in auxiliary terminals
M3.5
-
-
1SBC101537S0201
Other technical characteristics are the same as those of standard A contactors.
ABB | 5/283
UA... contactors
Terminal marking and positioning
UA... contactors - AC operated
Standard devices without addition of auxiliary contacts
A2
A1
1L1 3L2 5L3 13
NO
A1
1L1
3L2
5L3
A2
2T1
4T2
6T3
13
NO
NO
2T1 4T2 6T3 14
A2
UA16 ... UA30-30-10
UA16 ... UA30-30-10
A2
A1
3L2
1L1
NO
14
5L3
5
2T1
4T2
A1
1L1 3L2
5L3
A2
2T1 4T2
6T3
6T3
A2
UA50 ... UA110-30-00
UA50 ... UA110-30-00
Standard devices with factory mounted auxiliary contacts
A1
1L1
3L2
A2
5L3
NO 13X
NC 21X
NC 22X
A1
1L1 3L2
5L3
A2
2T1 4T2
6T3
NO 14X
2T1
4T2
6T3
A2
21X
NC
NO
14X
NC
22X
UA50 ... UA110-30-11
1SBC101571S0201
UA50 ... UA110-30-11
13X
NO
5/284 | ABB
UA.. 3-pole contactors for capacitor switching
Main dimensions
mm, inches
74 2.91"
68 2.68"
50 1.97"
35 mm EN/IEC 60715
74 2.91"
44 1.73"
4
0.16"
ø 4.5 0.18"
M4 8-32 UNC
60 2.36"
35 1.38"
5.5
0.22"
4.5
0.18"
4.5
0.18"
10 0.39"
UA16
UA16 drilling plan
5
108.3 4.26"
35 mm EN/IEC 60715
90 3.54"
54 2.13"
10 0.39"
4 0.16"
10 0.39"
UA30
70 2.76"
UA50, UA63, UA75-30-00
12
0.47"
70 2.76"
4.5
0.18"
108 4.25"
6 0.24"
ø 6.2 0.24"
M6 1/4-20 UNC
6.5 0.26"
90 3.54"
35 mm x15 EN/IEC 60715
UA26, UA30 drilling plan
4
0.16"
75 mm EN/IEC 60715
110 4.33"
74 2.91"
110 4.33"
UA26
4.5
0.18"
10 0.39"
10 0.39"
UA50, UA63, UA75-30-11
5
0.2"
60 2.36"
5
0.2"
Drilling plan
78 3.07"
90 3.54"
UA95, UA110-30-00
12
0.47"
90 3.54"
UA95, UA110-30-11
6
0.24"
10 0.39"
20 0.79"
ø 6.2 0.24"
M6 1/4-20 UNC
136 5.35"
126 4.96"
148 5.83"
74 2.91"
148 5.83"
123.5 4.86"
6.5 0.26"
6 0.24"
1SBC101572S0201
4 0.16"
ø 4.2 0.17"
M4 8-32 UNC
100 3.94"
35 mm EN/IEC 60715
90 3.54"
54 2.13"
45 1.77"
6.3 0.25"
80 3.15"
9 0.35"
6.3 0.25"
70 2.76"
93.6 3.69"
9 0.35"
6 0.24"
Drilling plan
ABB | 5/285
Summary_5-6
5
5/286 | ABB
Other contactor application data
Contactor selection
Control of three-phase slip-ring motors
5/288
Autotransformer starters
5/290
Three-phase transformer switching
5/291
Lighting circuit switching
5/293
Parallel connection of main poles
5/300
Temporary or intermittent duty
5/301
Summary_5-6
5
ABB | 5/287
Control of three-phase slip-ring motors
Contactor selection
General
Three kinds of contactors are used to control three-phase slip-ring motors: the stator contactor, the acceleration contactor(s) and the rotor shortcircuit contactor. Refer to the diagram opposite.
The selection tables below concern complete smooth starting, excluding specific cases, such as: intermittent operation, regenerative current,
controlled slipping, etc. for which you need to consult our specialised departments.
The starting and breaking technical data for slip-ring motors are defined in standard IEC 60947-4-1 in the AC-2 utilization category.
The load factor is defined by the equation:
Operating cycle
L.F. (%) =
x 100
Cycle time (Operating cycle + Rest cycle)
Stator contactor
Contactor types
Load factor
15 %
Ie / AC-2
25 %
Ie / AC-2
40 %
Ie / AC-2
60 %
Ie / AC-2
S7 acc. to IEC 60034-1: periodical
continuous duty with electrical breaking
A
A
A
A
A
AF09
18
15
13
11
9
AF12
24
20
17
14
12
AF16
33
31
26
22
18
AF26
52
44
38
31
26
AF30
64
54
46
38
32
AF38
76
65
55
46
38
AF40
79
68
58
48
40
AF52
106
90
77
64
53
AF65
124
111
94
78
65
AF80
154
136
116
96
80
AF96
184
163
139
115
96
Acceleration contactors
The sizing of these contactors is based on the AC-1 rated operational current (see "Technical data") that we recall below for the maximum ambient
temperature of 60 °C for AF09 to AF370 and 55 °C for AF400 to AF1650.
The table below lists the factors to be applied to the AC-1 current of the contactors in order to obtain the maximal permissible value of the
rotor current after contactor closing for star connection. If delta connection is used, increase by 50 % this current. This table takes into account
the number of cycles an hour (without inching) and the current flow time per cycle, in the contactor.
Number of cycles an hour
Current flow time per cycle
5s
10 s
20 s
30 s
40 s
60 s
Contactors
Rated operational current Ie / AC-1
for air temperature near the contactor
≤ 60 °C
A
1
3
6
Factors applicable to Ie / AC-1
5.2
4.9
4.7
3.8
3.6
3.4
2.8
2.7
2.6
2.4
2.3
2.2
2.2
2.1
2.0
1.9
1.8
1.8
12
20
30
60
120
4.3
3.1
2.5
2.1
1.9
1.7
4.0
3.0
2.4
2.1
1.9
1.7
3.7
2.8
2.2
1.9
1.7
1.5
3.4
2.6
2.0
1.7
1.5
-
2.8
2.2
1.6
-
AF09
25
AF26
40
AF30
42
AF38
42
AF40
60
AF52
80
AF12
28
AF16
30
AF65
90
AF80
100
AF96
105
Rotor short-circuit contactor
The duty of this contactor is characterized by small closing stresses. The decisive factor is the thermal stress. Delta connection of the contactor is
considered (reduce currents by 35 % if star connection is used).
The following table gives the permissible values of the rated operational rotor current, as a function of load factor.
Temperature: 60 °C for AF09 to AF370 and 55 °C for AF400 to AF1650 maximum near the contactor.
Contactor types
Load factor
15 %
Ie / AC-2
25 %
Ie / AC-2
40 %
Ie / AC-2
60 %
Ie / AC-2
S7 acc. to IEC 60034-1: periodical
continuous duty with electrical breaking
Rated operational rotor voltage:
– Maximum values for starting and
breaking
– Maximum values for starting and
electrical braking
5/288 | ABB
A
A
A
A
A
AF09
63
57
49
43
36
AF12
71
64
55
48
41
AF16
76
69
59
51
44
V
1380 (1600 in star connection)
V
690 (730 in star connection)
AF26
102
92
78
68
58
AF30
107
96
82
72
61
AF38
107
96
82
72
61
AF40
152
137
117
103
87
AF52
203
183
157
137
116
AF65
228
206
176
154
131
AF80
254
229
196
171
145
AF96
266
241
206
180
152
2000
(2300 in star connection)
690
(730 in star connection)
1SBC101969S0201
5
Closing of the starting current, conditioned by the value of the rotor resistances: it may reach 1.5 to 4 times rated motor operational current.
Breaking of the rated operational current, or of the starting current, with possible regenerative current.
The following table gives the permissible values of the Ie / AC-2 rated operational stator current, as a function of load factor.
Temperature of 60 °C for AF09 ... AF370 and 55 °C for AF400 ... AF1650 maximum near the contactor.
Maximum switching frequency and electrical durability in AC-2 category: see "Technical data".
Control of three-phase slip-ring motors
Contactor selection
Example of a three-stroke starter
–– The first stroke corresponds to energization of the motor by the stator contactor: all the resistances are operational in the rotor circuit
–– At the second stroke, the acceleration contactor short-circuits the
first resistance stack
–– At the third stroke, the rotor short-circuit contactor is
activated by eliminating the last resistance stack, thus completing
the starting period.
Rotor short-circuit
contactor
Stator
contactor
Acceleration
contactor
R2
R1
M
3
5
Contactors
Rated operational current Ie / AC-1
for air temperature near the contactor
≤ 60 °C (AF116-AF370) ≤ 55 °C
(AF400-AF1650)
Contactor types
Load factor
15 %
Ie / AC-2
25 %
Ie / AC-2
40 %
Ie / AC-2
60 %
Ie / AC-2
S7 acc. to IEC 60034-1: periodical
continuous duty with electrical breaking
Rated operational rotor voltage:
–M
aximum values for starting and
breaking
–M
aximum values for starting and
electrical braking
A
A
A
A
A
AF116
220
185
150
135
116
AF140
335
270
215
180
140
AF370
750
620
515
430
370
AF400
850
680
580
480
400
AF460
950
780
650
550
460
AF580
1150
975
800
700
580
AF750
1500
1250
1050
900
750
AF1350
1720
1430
1200
1030
860
A
AF116 AF140 AF190 AF205 AF265 AF305 AF370
145
175
250
300
350
400
500
AF400
500
AF460
600
AF580
700
AF750
800
AF1350 AF1650
1150
1450
A
A
A
A
A
AF116
330
300
260
230
200
AF400
1200
1050
950
810
700
AF460
1400
1250
1100
975
840
AF580
1650
1450
1300
1150
980
AF750
1900
1650
1450
1300
1150
AF1350
2400
2100
1850
1650
1500
AF140
540
490
425
375
300
AF190
360
300
250
220
190
AF190
580
530
460
400
350
2200
(2600 in star connection)
V 690
(730 in star connection)
V
AF205
425
350
300
255
210
AF205
750
650
575
500
380
AF265
530
440
370
315
265
AF265
830
725
630
575
480
AF305
625
515
430
370
305
AF305
950
830
720
650
550
AF370
1050
915
800
700
640
AF1650
2100
1750
1470
1250
1050
AF1650
2800
2500
2200
1950
1800
3000
(3600 in star connection)
1SBC101969S0201
Contactor types
Load factor
15 %
Ie / AC-2
25 %
Ie / AC-2
40 %
Ie / AC-2
60 %
Ie / AC-2
S7 acc. to IEC 60034-1: periodical
continuous duty with electrical breaking
ABB | 5/289
Autotransformer starters
Contactor selection
Electrical distribution
KM2
KM1
T1
Autotransformer
KM3
Selection Table (Id starting current / In nominal current < 8 - Acceleration time ≤ 20s - 30 cycles / h max.)
kW motor ratings 50/60 Hz
220/240 V
4
6.5
11
15
18.5
22
25
30
37
45
55
55
75
90
110
132
160
220
257
315
380/400 V
7.5
11
18.5
22
30
37
45
55
75
75
90
110
132
160
200
250
315
400
475
560
Contactors
KM1
line
415 V
7.5
11
18.5
30
37
45
55
55
75
75
90
110
132
160
200
250
355
425
500
600
440 V
7.5
11
18.5
30
37
45
55
75
90
90
110
132
160
160
200
250
355
450
560
670
690 V
9
15
22
30
37
45
55
55
75
90
132
160
200
250
315
355
500
600
-
AF16
AF26
AF38
AF52
AF65
AF80
AF96
AF116
AF140
AF146
AF190
AF205
AF265
AF305
AF370
AF460
AF580
AF750
AF1350
AF1650
KM2
autotransformer taps:
90 %
80 %
AF16
AF12
AF26
AF16
AF30
AF26
AF52
AF38
AF52
AF40
AF65
AF52
AF80
AF65
AF116
AF80
AF140
AF96
AF140
AF96
AF146
AF116
AF190
AF140
AF265
AF190
AF265
AF205
AF370
AF265
AF400
AF305
AF580
AF400
AF750
AF580
AF750
AF580
AF1350
AF750
KM3
star
70 %
AF09
AF16
AF26
AF30
AF30
AF40
AF52
AF65
AF80
AF80
AF96
AF116
AF140
AF190
AF190
AF265
AF305
AF400
AF460
AF580
60 %
AF09
AF09
AF16
AF26
AF26
AF30
AF38
AF52
AF65
AF65
AF65
AF80
AF96
AF116
AF140
AF190
AF205
AF305
AF400
AF460
AF09
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF65
AF65
AF80
AF96
AF116
AF140
AF190
AF205
AF305
AF400
AF460
AF580
1SBC101699S0201 - Rev. A
5
General
An autotransformer starter allows to start a squirel cage motor
with a reduced starting current due to the reduced voltage
within the accelerating duration.
Unlike the star-delta wiring, this autotransformer starting
method needs three wires and three terminals on the motor.
At the starting period, the motor is wired to the autotransformer taps: the star contactor "KM3" and the autotransformer contactor "KM2" are closed, the motor is under reduced
voltage. Consequently, the torque is reduced as the square
of the applied voltage. The autotransformers are generally
equipped of three taps at each phase in order to adapt the
starting parameters to the field requirements.
When the motor reaches 80...95 % of its nominal speed, the
star contactor opens. Then, the line contactor "KM1" is making and the autotransformer contactor is opening. This starting process is done without any network interruption.
5/290 | ABB
Three-phase transformer switching
Contactor selection
AC-6a Utilization category according to IEC 60947-4-1
General
Switching the primary of 3-phase transformers, on energization of the transformer, is characterized by high current peaks due to the
magnetization phenomena.
Selection Table
The tables below show the operational ratings for:
–– current peaks up to 20 to 30 times the transformer nominal current
–– maximum switching frequency of 60 operating cycles per hour
–– air ambient temperature ≤ 40 °C.
AC / DC operated contactors
AF09
AF12
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
Operational power at Ue: 50/60 Hz - according to AC-6a
220 / 240 V
kVA
4
5
6
10
13
14
15
19
21
23
25
380 / 400 V
kVA
7
8
10
17
22
25
26
33
36
39
44
415 / 440 V
kVA
8
9
11
18
24
27
28.5
36
40
43
48
500 V
kVA
9
11
13
22
28
32
34.5
43
48
52
57
660 / 690 V
kVA
12.5
14
18
29
37
43
45.5
57
64
68
75
A
350
400
500
800
1000
1200
1250
1550
1750
1900
2100
Max. permissible Îpeak
AC / DC operated contactors
5
AF116 AF140 AF190 AF205 AF265 AF370 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650
220 / 240 V
kVA
26
30
42
45
55
63
76
95
100
110
130
160
190
380 / 400 V
kVA
46
52
73
75
94
108
132
165
170
190
240
275
350
415 / 440 V
kVA
50
57
80
80
103
118
144
180
190
210
270
325
390
500 V
kVA
60
68
96
100
124
143
173
220
230
250
320
–
–
660 / 690 V
kVA
80
90
127
130
164
188
228
290
300
310
410
–
–
2100
2400
3300
3500
4300
4900
6000
7700
8400
9300
12000
–
–
Max. permissible Îpeak
A
1SBC101970S0201
Operational power at Ue: 50/60 Hz - according to AC-6a
ABB | 5/291
Notes
N8
5
5/292 | ABB
Lighting circuit switching
Contactor selection
General
Contactor selection criteria for control of lighting circuits are as follows:
– – type, power rating and number of lamps
–– connection mode
–– current values on closing and in steady state
–– power factor
–– presence or not of correction capacitors.
Lighting circuits
In a given circuit, the number and power rating of lamps are defined and cannot result in overload. Only short-circuit protection
has to be provided. gG fuses or modular circuit-breakers will be chosen for this purpose.
The lamps have very specific technical data, according to their construction type.
–– Incandescent lamps have a very high current on closing: more than 15 times nominal current.
They do not introduce a large phase displacement between current and voltage
– – Fluorescent tubes are equipped with a ballast whose purpose is two-fold: contribute to ignition and limit current to nominal
value once steady state is reached. This ballast is a reactor that considerably lowers the power factor. It may or may not be
compensated.
Individual compensation
(parallel compensation)
5
Serial compensation in dual mounting
S
S
S
Selection of contactors
The following tables indicate, for each contactor type, the maximum permissible number of lamps per phase. Air temperature,
near the contactor, must be limited to 60 °C. Numbers are given for a 230 V voltage distributed between phase and neutral:
single-phase (phase + neutral) or three-phase (3 phases + neutral) distribution, lamps are wired in star connection. In the case
of a three-phase supply without neutral, 230 V phase-to-phase, the permissible number of lamps per phase will be that given in
the tables multiplied by 0.58.
1SBC101961S0201
Example:
120 x 100 W / 230 V incandescent lamps - 400 V three-phase network with distributed neutral.
Calculate the number of lamps per phase: 120 : 3 = 40. On the 100 W line of the incandescent lamp table, contactor AF09 is
limited to 38 lamps per phase, you must thus select contactor AF12 which accepts up to 43 lamps per phase.
ABB | 5/293
Lighting circuit switching
Contactor selection AF09 ... AF146
Selection table
3-pole AC / DC operated contactors
AF09
Lamp characteristics
Maximum permissible number of lamps per phase
W
A
AF12
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
AF116 AF140 AF146
μF
Incandescent and halogen lamps
Voltage: 220/240 V AC
60
0.27
64
72
77
103
129
148
177
207
233
259
277
430
519
541
100
43
46
62
77
89
106
124
140
155
166
258
311
324
0.45
-
38
according to AC-5b
200
0.91
-
19
21
23
30
38
44
52
61
69
77
82
127
154
160
300
1.37
-
12
14
15
20
25
29
35
41
46
51
54
85
102
107
500
2.28
-
7
8
9
12
15
17
21
24
27
30
33
51
61
64
1000
4.55
-
3
4
4
6
7
8
10
12
13
15
16
25
31
32
5
Fluorescent lamps without compensation - Fluorescent lamps with electronic starter
Voltage: 220/240 V AC
20
0.38
46
51
55
73
84
92
126
147
157
184
210
305
368
384
40
133
155
177
258
311
324
0.45
-
38
43
46
62
71
77
106
124
according to AC-5a
65
0.70
-
25
27
30
40
45
50
68
80
85
100
114
166
200
209
80
0.80
-
21
24
26
35
40
43
60
70
75
87
100
145
175
183
100
1.15
-
15
16
18
24
27
30
41
48
52
60
69
101
122
127
110
1.20
-
14
16
17
23
26
29
40
46
50
58
66
97
117
122
Fluorescent lamps with parallel compensation
Voltage: 220/240 V AC
20
0.18
5
53
53
53
155
168
176
266
309
325
388
444
644
778
811
40
107
123
134
184
215
230
269
307
446
538
562
0.26
5
53
53
53
according to AC-5a
65
0.42
7
37
37
37
66
76
83
114
133
142
166
190
276
333
348
80
0.52
7
33
37
37
53
61
67
92
107
115
134
153
223
269
281
100
0.65
16
16
16
16
43
49
53
73
86
92
107
123
178
215
225
110
0.70
18
14
14
14
40
45
49
68
80
85
100
114
166
200
209
Fluorescent lamps in dual mounting
Voltage: 220/240 V AC
2 x 20
2 x 0.14
62
69
75
100
114
125
171
200
214
250
285
414
500
521
2 x 40
39
42
56
64
70
96
112
120
140
160
232
280
292
183
2 x 0.25
-
35
according to AC-5a
2 x 65
2 x 0.40
-
21
24
26
35
40
43
60
70
75
87
100
145
175
2 x 80
2 x 0.48
-
18
20
21
29
33
36
50
58
62
72
83
121
146
152
2 x 100
2 x 0.60
-
14
16
17
23
26
29
40
46
50
58
66
97
117
122
2 x 110
2 x 0.65
-
13
15
16
21
24
26
36
43
46
53
61
89
108
112
Compact fluorescent lamps
Voltage: 220/240 V AC
5
0.045
-
388
433
466
622
711
777
1066
1244
1333
1555
1777
2578
3111
3244
7
233
260
280
373
426
466
640
746
800
933
1066
1547
1867
1947
0.075
-
according to AC-5a
11
0.105
-
166
185
200
266
304
333
457
533
571
666
761
1105
1333
1390
15
0.135
-
129
144
155
207
237
259
355
414
444
518
592
859
1037
1081
0.160
-
109
121
131
175
200
218
300
350
375
437
500
725
875
913
0.180
-
97
108
116
155
177
194
266
311
333
388
444
644
778
811
1SBC101961S0201
20
23
5/294 | ABB
Lighting circuit switching
Contactor selection AF190 ... AF2650
Selection table
3-pole AC / DC operated contactors
AF190
Lamp characteristics
Maximum permissible number of lamps per phase
W
A
AF205
AF265
AF305
AF370
AF400
AF460
AF580
AF750
AF1250 AF1350 AF1650 AF2050 AF2650
μF
Incandescent and halogen lamps
Voltage: 220/240 V AC
60
0.27
704
759
981
1130
1370
1481
1704
2148
2778
3009
3250
3972
4935
6380
100
456
589
678
822
889
1022
1289
1667
1806
1950
2383
2961
3828
0.45
-
422
according to AC-5b
200
0.91
-
209
225
291
335
407
440
505
637
824
893
964
1179
1464
1893
300
1.37
-
139
150
193
223
270
292
336
423
547
593
641
783
973
1257
500
2.28
-
83
90
116
134
162
175
202
254
329
356
385
470
584
755
1000
4.55
-
42
45
58
67
81
88
101
127
165
179
193
236
293
379
5
Fluorescent lamps without compensation - Fluorescent lamps with electronic starter
Voltage: 220/240 V AC
20
0.38
500
539
697
803
974
1053
1211
1526
1974
2138
2309
2822
3507
4533
40
1667
1806
1950
2383
2961
3828
0.45
-
422
456
589
678
822
889
1022
1289
according to AC-5a
65
0.70
-
271
293
379
436
529
571
657
829
1071
1161
1254
1532
1904
2461
80
0.80
-
238
256
331
381
463
500
575
725
938
1016
1097
1341
1666
2153
100
1.15
-
165
178
230
265
322
348
400
504
652
707
763
933
1159
1498
110
1.20
-
158
171
221
254
308
333
383
483
625
677
731
894
1110
1435
Fluorescent lamps with parallel compensation
Voltage: 220/240 V AC
20
0.18
5
1056
1139
1472
1694
2056
2222
2556
3222
4167
4514
4875
5958
7403
9569
40
1173
1423
1538
1769
2231
2885
3125
3375
4125
5125
6625
0.26
5
731
788
1019
according to AC-5a
65
0.42
7
452
488
631
726
881
952
1095
1381
1786
1935
2089
2554
3173
4101
80
0.52
7
365
394
510
587
712
769
885
1115
1442
1563
1688
2063
2563
3313
100
0.65
16
292
315
408
469
569
615
708
892
1154
1250
1350
1650
2050
2650
110
0.70
18
271
293
379
436
529
571
657
829
1071
1161
1254
1532
1904
2461
Fluorescent lamps in dual mounting
Voltage: 220/240 V AC
2 x 20
2 x 0.14
679
732
946
1089
1321
1429
1643
2071
2679
2902
3134
3830
4759
6152
2 x 40
410
530
610
740
800
920
1160
1500
1625
1755
2145
2665
3445
2153
2 x 0.25
-
380
according to AC-5a
2 x 65
2 x 0.40
-
238
256
331
381
463
500
575
725
938
1016
1097
1341
1666
2 x 80
2 x 0.48
-
198
214
276
318
385
417
479
604
781
846
914
1117
1388
1794
2 x 100
2 x 0.60
-
158
171
221
254
308
333
383
483
625
677
731
894
1110
1435
2 x 110
2 x 0.65
-
146
158
204
235
285
308
354
446
577
625
675
825
1025
1325
Compact fluorescent lamps
Voltage: 220/240 V AC
5
0.045
-
4222
4556
5889
6778
8222
8889
10222
12889
16667
18056
19500
23833
29611
38278
7
2533
2733
3533
4067
4933
5333
6133
7733
10000
10833
11700
14300
17767
22967
0.075
-
according to AC-5a
11
0.105
-
1810
1952
2524
2905
3524
3810
4381
5524
7143
7738
8357
10214
12690
16405
15
0.135
-
1407
1519
1963
2259
2741
2963
3407
4296
5556
6019
6500
7944
9870
12759
0.160
-
1188
1281
1656
1906
2313
2500
2875
3625
4688
5078
5484
6703
8328
10766
0.180
-
1056
1139
1472
1694
2056
2222
2556
3222
4167
4514
4875
5958
7403
9569
1SBC101961S0201
20
23
ABB | 5/295
Lighting circuit switching
Contactor selection AF09 ... AF146
Selection table
3-pole AC / DC operated contactors
AF09
Lamp characteristics
Maximum permissible number of lamps per phase
5
A
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
AF116 AF140 AF146
μF
Low pressure sodium vapour lamps without compensation
Voltage: 220/240 V AC
35
1.4
9
10
12
15
15
16
23
31
35
39
42
70
85
89
55
15
16
23
31
35
39
42
70
85
89
1.4
-
9
10
12
15
90
2.1
-
6
7
8
10
10
10
15
20
23
26
28
47
57
59
135
3.1
-
4
4
5
6
7
7
10
14
15
17
19
32
38
40
180
3.1
-
4
4
5
6
7
7
10
14
15
17
19
32
38
40
Low pressure sodium vapour lamps with parallel compensation
Voltage: 220/240 V AC
35
0.6
20
12
12
12
35
36
38
55
73
81
91
100
164
198
207
55
38
55
73
81
91
100
164
198
207
0.6
20
12
12
12
35
36
90
0.9
25
10
10
10
23
24
25
36
48
55
61
66
110
132
138
135
0.9
45
5
5
5
18
18
19
34
34
36
57
59
110
132
138
180
0.9
45
5
5
5
18
18
19
34
34
36
57
59
110
132
138
High pressure sodium vapour lamps without compensation
Voltage: 220/240 V AC
150
1.8
7
8
9
11
12
12
18
24
27
30
33
45
54
57
250
7
7
11
14
16
18
20
27
33
34
3.0
-
4
5
5
7
400
4.4
-
3
3
3
4
5
5
7
10
11
12
13
18
22
23
600
6.2
-
2
2
2
3
3
3
5
7
7
8
9
13
16
16
1000
10.3
-
1
1
1
2
2
2
3
4
4
5
5
8
10
10
High pressure sodium vapour lamps with parallel compensation
Voltage: 220/240 V AC
150
1.0
20
12
12
12
21
22
23
33
43
49
55
60
93
112
117
250
15
22
29
33
36
40
62
75
78
1.5
36
7
7
7
14
14
400
2.5
48
5
5
5
8
8
9
13
17
19
22
24
37
45
47
600
3.3
65
3
3
3
6
6
6
10
13
15
16
18
28
34
35
1000
6.2
100
2
2
2
3
3
3
5
7
7
8
9
15
18
19
214
High pressure mercury vapour lamps without compensation
Voltage: 220/240 V AC
50
0.60
22
25
28
35
36
38
55
73
82
91
100
152
190
80
0.80
-
16
18
21
26
27
28
41
55
61
68
75
114
143
160
125
1.15
-
11
13
14
18
19
20
28
38
43
47
52
79
99
112
250
2.15
-
6
6
7
9
10
10
15
20
23
25
27
42
53
60
400
3.25
-
4
4
5
6
6
7
10
13
15
16
18
28
35
39
700
5.40
-
2
2
3
3
4
4
6
8
9
10
11
17
21
24
1000
7.50
-
1
2
2
2
2
3
4
5
6
7
8
12
15
17
Voltage: 380/415 V AC
2000
8.00
-
1
1
2
2
2
2
4
5
6
6
7
11
14
16
High pressure mercury vapour lamps with compensation
Voltage: 220/240 V AC
50
0.28
7
36
36
36
75
78
82
117
157
176
196
214
326
407
458
80
51
53
76
102
115
127
139
212
265
298
0.43
8
31
31
31
48
125
0.66
10
20
22
25
31
33
34
50
66
75
83
90
138
173
194
250
1.28
18
10
11
13
16
17
17
25
34
38
42
46
71
89
100
400
2.05
25
6
7
8
10
10
11
16
21
24
26
29
44
56
63
700
3.55
40
3
4
4
5
6
6
9
12
13
15
16
26
32
36
1000
4.83
60
2
3
3
4
4
4
6
9
10
11
12
19
24
27
Voltage: 380/415 V AC
2000
5.45
35
2
2
3
3
4
4
6
8
9
10
11
17
21
24
5/296 | ABB
1SBC101961S0201
W
AF12
Lighting circuit switching
Contactor selection AF190 ... AF2650
Selection table
3-pole AC / DC operated contactors
AF190
Lamp characteristics
Maximum permissible number of lamps per phase
A
AF265
AF305
AF370
AF400
AF460
AF580
AF750
AF1250 AF1350 AF1650 AF2050 AF2650
μF
Low pressure sodium vapour lamps without compensation
Voltage: 220/240 V AC
35
1.4
115
124
161
185
225
243
279
352
455
493
533
651
809
1046
55
225
243
279
352
455
493
533
651
809
1046
1.4
-
115
124
161
185
90
2.1
-
77
83
107
123
150
162
186
235
304
329
355
434
539
697
135
3.1
-
52
56
73
84
101
110
126
159
206
223
241
294
365
472
180
3.1
-
52
56
73
84
101
110
126
159
206
223
241
294
365
472
Low pressure sodium vapour lamps with parallel compensation
Voltage: 220/240 V AC
35
0.6
20
269
290
375
432
524
567
652
822
1063
1151
1243
1519
1888
2440
55
0.6
20
269
290
375
432
524
567
652
822
1063
1151
1243
1519
1888
2440
90
0.9
25
179
194
250
288
349
378
434
548
708
767
829
1013
1258
1627
135
0.9
45
179
194
250
288
349
378
434
548
708
767
829
1013
1258
1627
180
0.9
45
179
194
250
288
349
378
434
548
708
767
829
1013
1258
1627
High pressure sodium vapour lamps without compensation
Voltage: 220/240 V AC
150
1.8
74
80
103
119
144
156
179
226
292
313
338
413
513
663
250
86
93
107
135
175
188
203
248
308
398
3.0
-
44
48
62
71
400
4.4
-
30
33
42
49
59
64
73
92
119
128
138
169
210
271
600
6.2
-
21
23
30
34
42
45
52
65
85
91
98
120
149
192
1000
10.3
-
13
14
18
21
25
27
31
39
51
55
59
72
90
116
High pressure sodium vapour lamps with parallel compensation
Voltage: 220/240 V AC
150
1.0
20
152
164
212
244
296
320
368
464
600
625
675
825
1025
1325
250
213
245
309
400
417
450
550
683
883
1.5
36
101
109
141
163
197
400
2.5
48
61
66
85
98
118
128
147
186
240
250
270
330
410
530
600
3.3
65
46
50
64
74
90
97
112
141
182
189
205
250
311
402
1000
6.2
100
25
26
34
39
48
52
59
75
97
101
109
133
165
214
2518
High pressure mercury vapour lamps without compensation
Voltage: 220/240 V AC
50
0.60
261
333
380
475
570
570
665
760
998
1188
1283
1568
1948
80
0.80
-
196
249
285
356
428
428
499
570
748
891
962
1176
1461
1888
125
1.15
-
136
173
198
248
297
297
347
397
520
620
669
818
1016
1313
250
2.15
-
73
93
106
133
159
159
186
212
278
331
358
437
543
703
400
3.25
-
48
61
70
88
105
105
123
140
184
219
237
289
360
465
700
5.40
-
29
37
42
53
63
63
74
84
111
132
143
174
216
280
1000
7.50
-
21
27
30
38
46
46
53
61
80
95
103
125
156
201
Voltage: 380/415 V AC
2000
8.00
-
20
25
29
36
43
43
50
57
75
89
96
118
146
189
High pressure mercury vapour lamps with compensation
Voltage: 220/240 V AC
50
0.28
7
560
713
814
1018
1221
1221
1425
1629
2138
2545
2748
3359
4173
5395
80
795
795
928
1060
1392
1657
1790
2187
2717
3513
0.43
8
365
464
530
663
125
0.66
10
238
302
345
432
518
518
605
691
907
1080
1166
1425
1770
2289
250
1.28
18
122
156
178
223
267
267
312
356
468
557
601
735
913
1180
400
2.05
25
76
97
111
139
167
167
195
222
292
348
375
459
570
737
700
3.55
40
44
56
64
80
96
96
112
128
169
201
217
265
329
425
1000
4.83
60
32
41
47
59
71
71
83
94
124
148
159
195
242
313
Voltage: 380/415 V AC
2000
5.45
35
29
37
42
52
63
63
73
84
110
131
141
173
214
277
ABB | 5/297
5
1SBC101961S0201
W
AF205
Lighting circuit switching
Contactor selection AF09 ... AF146
Selection table
3-pole AC / DC operated contactors
AF09
Lamp characteristics
Maximum permissible number of lamps per phase
W
AF16
AF26
AF30
AF38
AF40
AF52
AF65
AF80
AF96
AF116 AF140 AF146
μF
Metal halide vapour lamps without compensation
Voltage: 220/240 V AC
250
3
4
5
5
7
7
7
11
14
16
18
20
27
33
38
400
5
5
5
8
11
12
13
15
20
25
28
4
-
3
3
4
1000
9.5
-
1
1
1
2
2
2
3
4
5
5
6
8
11
12
2000
16.5
-
0
0
1
1
1
1
2
2
3
3
3
5
6
7
Voltage: 380/415 V AC
2000
10.5
-
1
1
1
2
2
2
3
4
4
5
5
8
10
11
Metal halide vapour lamps with compensation
Voltage: 220/240 V AC
250
1.32
33
7
7
7
15
16
17
25
33
37
41
45
69
86
97
400
9
9
10
14
19
22
24
27
41
51
58
2.22
45
5
5
5
1000
5.14
85
2
2
3
4
4
4
6
8
9
10
11
18
22
25
2000
11.5
148
1
1
1
1
1
2
2
3
4
4
5
8
10
11
2
2
2
3
3
3
5
7
8
9
9
15
19
21
Voltage: 380/415 V AC
2000
6.10
60
1SBC101961S0201
5
A
AF12
5/298 | ABB
Lighting circuit switching
Contactor selection AF190 ... AF2650
Selection table
3-pole AC / DC operated contactors
AF190
Lamp characteristics
Maximum permissible number of lamps per phase
W
A
AF205
AF265
AF305
AF370
AF400
AF460
AF580
AF750
AF1250 AF1350 AF1650 AF2050 AF2650
μF
Metal halide vapour lamps without compensation
Voltage: 220/240 V AC
250
3
46
58
67
83
100
100
117
133
175
208
225
275
342
442
400
63
75
75
88
100
131
156
169
206
256
331
4
-
34
44
50
1000
9.5
-
14
18
21
26
32
32
37
42
55
66
71
87
108
139
2000
16.5
-
8
11
12
15
18
18
21
24
32
38
41
50
62
80
13
17
19
24
29
29
33
38
50
60
64
79
98
126
Voltage: 380/415 V AC
2000
10.5
-
5
Metal halide vapour lamps with compensation
Voltage: 220/240 V AC
250
1.32
33
119
151
173
216
259
259
302
345
453
540
583
713
885
1144
400
128
154
154
180
205
270
321
347
424
526
680
2.22
45
71
90
103
5.14
85
30
39
44
55
67
67
78
89
116
139
150
183
227
294
11.5
148
14
17
20
25
30
30
35
40
52
62
67
82
102
131
26
33
37
47
56
56
65
75
98
117
126
154
192
248
Voltage: 380/415 V AC
2000
6.10
60
1SBC101961S0201
1000
2000
ABB | 5/299
Parallel connection of main poles
General
Purpose: Increasing the AC resistive load by wiring connection of main poles in parallel.
Remarks:
–– Parallel connection of main poles to increase the DC resistive load is not acceptable
–– Parallel connection of main poles does not increase the breaking capacity.
The table below shows the uprating factor for Ie / AC-1 max. in relation to the number of poles wired connected in parallel and for a maximum
switching frequency.
Note: The poles can be connected in parallel via following connecting strips. See details and permissible current in "Accessory" part.
–– LP, LH, LY and LF for parallel connection of 2 or 3 poles
–– LG for parallel connection of 4 poles.
L1
L2
L3
2 poles in parallel
N
3 poles in parallel
N
A827D
L1
L2
L3
A826D
N
A825D
L1
L2
L3
5
4 poles in parallel
Contactors
AC operated
DC operated
Cycles / h
Factor to be applied to the rated operational current Ie / AC-1 to obtain the permissible current
Ie / AC-1 with "n" poles in parallel
3-pole contactors
AF09 ... AF96
AF116 … AF1250
AF1350 … AF2650
AF09 ... AF96
AF116 … AF1250
AF1350 … AF2650
600
300
30
1.6
1.6
1.6
2.2
2.2
2.2
–
–
–
AF09 ... AF38
600
1.6
2.2
2.6
AE45 ... AE75
TAE45 ... TAE75
AF45 ... AF75
EK
300
1.6
2.2
2.6
300
1.6
2.2
2.8
4-pole contactors
AF09 ... AF38
A45 ... A75
AF45 ... AF75
1SBC101972S0201
EK
5/300 | ABB
Temporary or intermittent duty
Utilization of contactors for temporary / intermittent duty
The table below shows the factor (known as "On-load factor") to be applied to the rated operational current Ie / AC-1 to obtain the
permissible operational current Ie / AC-1 in relation to the switching frequency and the current flow time per cycle.
Operating cycles per hour
1
2
3
6
12
20
30
60
120
Prefered classes acc. to IEC 60947-4-1
1
–
3
–
12
–
30
–
120
Current flow time per cycle
Factors applicable to Ie / AC-1
5
4.9
4.7
4.3
4.0
3.7
3.4
2.8
10 s 3.8
5 s 5.2
3.7
3.6
3.4
3.1
3.0
2.8
2.6
2.2
20 s 2.8
2.7
2.7
2.6
2.5
2.4
2.2
2.0
1.5
30 s 2.4
2.3
2.3
2.2
2.1
2.1
1.9
1.7
–
40 s 2.2
2.1
2.1
2.0
1.9
1.9
1.7
1.5
–
60 s 1.9
1.8
1.8
1.8
1.7
1.7
1.5
–
–
5
Example:
AF09 contactor (intermittent duty, resistive load)
(see "Technical data: main pole utilization characteristics")
25 A
Switching frequency
2 operating cycles/h
Current flow time per cycle
20 s
Factor to be applied to the current Ie / AC-1
2.7
Permissible current: 2.7 x 25 =
67 A
1SBC101971S0201
Rated operational current Ie / AC-1 at 60 °C
ABB | 5/301
Summary_5-7
5
5/302 | ABB
NF 4-pole and 8-pole contactor relays
Ordering details 4-pole contactor relays
NF
AC / DC operated
5/304
NFZ
AC / DC operated - low consumption
5/305
Main accessories
5/306
Ordering details 8-pole contactor relays
NF
AC / DC operated
5/308
NFZ
AC / DC operated - low consumption
5/309
5/310
Technical data
5/312
Terminal marking and positioning
5/315
Main dimensions
5/317
Voltage code table
5/392
5
Summary_5-7
Main accessories
ABB | 5/303
NF 4-pole contactor relays
AC / DC operated
Description
1SBC101104F0014
NF contactor relays are used for switching auxiliary and control circuits.
NF22E
These contactor relays are of the block type design with:
–– 4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
Number of contacts
5
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
Rated control circuit
voltage
Uc min. ... Uc max.
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
V DC
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
Type
Order code
Weight
Pkg
(1 pce)
(1) NF22E-41
NF22E-12
NF22E-13
NF22E-14
(1) NF31E-41
NF31E-12
NF31E-13
NF31E-14
(1) NF40E-41
NF40E-12
NF40E-13
NF40E-14
1SBH137001R4122
1SBH137001R1222
1SBH137001R1322
1SBH137001R1422
1SBH137001R4131
1SBH137001R1231
1SBH137001R1331
1SBH137001R1431
1SBH137001R4140
1SBH137001R1240
1SBH137001R1340
1SBH137001R1440
kg
0.270
0.270
0.270
0.310
0.270
0.270
0.270
0.310
0.270
0.270
0.270
0.310
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use NF..E-11 (see voltage code table).
NF..E-11 not suitable for direct control by PLC-output.
Main dimensions
mm, inches
77 3.03"
35 1.38"
10 0.39"
5 0.20"
NF22E, NF31E, NF40E
5/304 | ABB
1SBC101558S0201 - Rev. A
60 2.36"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
ø 4.2 0.17"
5.5 0.22"
5 0.20"
71 2.80"
45 1.77"
NFZ 4-pole contactor relays
AC / DC operated - low consumption
Description
Ordering details
Number of contacts
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
Rated control circuit
voltage
Uc min. ... Uc max.
V 50/60 Hz
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
24...60
48...130
100...250
Type
Order code
5
Weight
Pkg
(1 pce)
V DC
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
NFZ22E-20
NFZ22E-21
NFZ22E-22
NFZ22E-23
NFZ31E-20
NFZ31E-21
NFZ31E-22
NFZ31E-23
NFZ40E-20
NFZ40E-21
NFZ40E-22
NFZ40E-23
1SBH136001R2022
1SBH136001R2122
1SBH136001R2222
1SBH136001R2322
1SBH136001R2031
1SBH136001R2131
1SBH136001R2231
1SBH136001R2331
1SBH136001R2040
1SBH136001R2140
1SBH136001R2240
1SBH136001R2340
kg
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the
coil terminals: A1+ for the positive pole and A2- for the negative pole.
mm, inches
77 3.03"
35 1.38"
60 2.36"
35 mm EN/IEC 60715
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
ø 4.2 0.17"
5.5 0.22"
1SBC101559S0201 - Rev. A
71 2.80"
45 1.77"
5 0.20"
Main dimensions
6 0.24"
NFZ22E
These contactor relays are of the block type design with:
–– 4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
80 3.15"
1SBC101104F0014
NFZ contactor relays are used for switching auxiliary and control circuits.
10 0.39"
5 0.20"
NFZ22E, NFZ31E, NFZ40E
ABB | 5/305
NF 4-pole contactor relays
Main accessories
Contactor relays and main accessories (other accessories available)
NF contactor relay
TEF4
Electronic timer
BX4-CA
Protective cover
5
CAL4-11
2-pole auxiliary
contact block
CA4
4-pole auxiliary
contact block
BX4
Protective cover
BX4-CA
Protective cover
CA4, CC4
1-pole auxiliary
contact block
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor relay
types
Front-mounted accessories
Auxiliary contact blocks
Main
poles
Electronic timer
Side-mounted accessories
Auxiliary contact blocks
TEF4
2-pole CAL4-11
1-pole CA4
1-pole CC4
Left side
4-pole CA4
Right side
Max. add-on N.C. auxiliary contacts: 3 N.C. max. on positions 1, 2, 3, 4 and 2 N.C. max. on positions 1 ±30°, 5
NF
2
3
2
1
E
E
4 max.
2 max.
4
0
E
4 max.
2 max.
or 1
–
or 1
or 1
+
+
1
1
+
–
1
+
–
1
Max. add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5
or 1
–
or 1
or 1
+
+
1
1
1SBC101518S0201 - Rev. A
NF
5/306 | ABB
NF 4-pole contactor relays
Main accessories
Ordering details (1)
1SBC101108F0014
For contactor relays
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
CA4-10
1SBC101123F0014
Front-mounted instantaneous auxiliary contact blocks
4-pole NF
1 0
– –
CA4-10
1 0
– –
CA4-10-T
0 1
– –
CA4-01
0 1
– –
CA4-01-T
4 0
– –
CA4-40N
3 1
– –
CA4-31N
2 2
– –
CA4-22N
1 3
– –
CA4-13N
NF..40E
0 4
– –
CA4-04N
1SBC101112F0014
CA4-22N
CAL4-11
1SBN010110R1010
1SBN010110T1010
1SBN010110R1001
1SBN010110T1001
1SBN010140R1240
1SBN010140R1231
1SBN010140R1222
1SBN010140R1213
1SBN010140R1204
1
10
1
10
1
1
1
1
1
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
4-pole NF
– –
1 0
CC4-10
1SBN010111R1010
1
– –
0 1
CC4-01
1SBN010111R1001
1
0.014
0.014
Side-mounted instantaneous auxiliary contact blocks
NF
1 1
– –
CAL4-11
1 1
– –
CAL4-11-T
1SBN010120R1011
1SBN010120T1011
1
10
0.040
0.040
For contactors
Order code
Pkg
qty
Weight
(1 pce)
Time delay
range
Delay
type
Auxiliary Type
contacts
1SBC101392F0014
selected by
switch
1SBC101133F0014
TEF4-ON
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
0.055
Electronic timers
NF
0.1...1 s
1...10 s
10...100 s
5
kg
ON-delay
1 1
TEF4-ON
1SBN020112R1000
1
0.065
OFF-delay
1 1
TEF4-OFF
1SBN020114R1000
1
0.065
Additional coil terminal block
NF
LDC4
1SBN070156T1000
10
0.010
Protective covers
All 1-stack contactor relays
4-pole CA4 auxiliary contact blocks and TEF4 electronic timer
BX4
BX4-CA
1SBN110108T1000
1SBN110109W1000
10
50
0.006
0.001
Note: Rated control circuit voltage Uc 24...240 V 50/60 Hz or DC.
(1) For more information, refer to main catalog "Accessories" section.
1SBC101136F0014
LDC4
1SBC101519S0201 - Rev. A
1SBC101138F0014
BX4
BX4-CA
ABB | 5/307
NF 8-pole contactor relays
AC / DC operated
Description
1SBC101029V0014
NF contactor relays are used for switching auxiliary and control circuits.
NF44E
These contactor relays are of the block type design with:
–– 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked
auxiliary contact elements (side-marked symbol) except for NF33/11 and NF51/11 variants
–– overlapping of lagging / leading contacts for NF33/11 and NF51/11 variants
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC
-- reduced panel energy consumption
-- very distinct closing and opening
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
5
Number of contacts
1SBC101042V0014
1st stack
Rated control circuit
voltage
Uc min. ... Uc max.
2nd stack
1SBC101043V0014
V DC
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
Order code
Weight
Pkg
(1 pce)
kg
8-pole contactor relays
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
NF33/11
NF51/11
V 50/60 Hz
Type
(1) NF44E-41
NF44E-12
NF44E-13
NF44E-14
(1) NF53E-41
NF53E-12
NF53E-13
NF53E-14
(1) NF62E-41
NF62E-12
NF62E-13
NF62E-14
(1) NF71E-41
NF71E-12
NF71E-13
NF71E-14
(1) NF80E-41
NF80E-12
NF80E-13
NF80E-14
8-pole contactor relays with overlapping of lagging / leading contacts
24...60
(1) NF33/11-41
A1
41
13
23
33
51
61
75
87
NO NO NO NC NC NC NC NO
48...130
48...130
NF33/11-12
100...250
100...250
NF33/11-13
NO NO NO NC NC NC NC NO
14
24
34
42
52
62
76
88
A2
250...500
250...500
NF33/11-14
24...60
(1) NF51/11-41
A1
43
13
23
33
53
61
75
87
NO NO NO NO NO NC NC NO
48...130
48...130
NF51/11-12
100...250
100...250
NF51/11-13
NO NO NO NO NO NC NC NO
14
24
34
44
54
62
76
88
A2
250...500
250...500
NF51/11-14
1SBH137001R4144
1SBH137001R1244
1SBH137001R1344
1SBH137001R1444
1SBH137001R4153
1SBH137001R1253
1SBH137001R1353
1SBH137001R1453
1SBH137001R4162
1SBH137001R1262
1SBH137001R1362
1SBH137001R1462
1SBH137001R4171
1SBH137001R1271
1SBH137001R1371
1SBH137001R1471
1SBH137001R4180
1SBH137001R1280
1SBH137001R1380
1SBH137001R1480
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
1SBH137001R4139
1SBH137001R1239
1SBH137001R1339
1SBH137001R1439
1SBH137001R4159
1SBH137001R1259
1SBH137001R1359
1SBH137001R1459
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use NF..-11 (see voltage code table).
NF..-11 not suitable for direct control by PLC-output.
Main dimensions
mm, inches
110.5 4.35"
35 1.38"
NF44E, NF53E, NF62E, NF71E, NF80E, NF33/11, NF51/11
5/308 | ABB
2x
M4 8-32 UNC
70 2.76"
60 2.36"
43 1.69"
35 mm EN/IEC 60715
6 0.24"
80 3.15"
5.5 0.22"
ø 4.2 0.17"
5 0.20"
1SBC101560S0201 - Rev. B
10 0.39"
5.5 0.22"
5 0.20"
71 2.80"
45 1.77"
NFZ 8-pole contactor relays
AC / DC operated
Description
1SBC101029V0014
NFZ contactor relays are used for switching auxiliary and control circuits.
NFZ44E
These contactor relays are of the block type design with:
–– 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked
auxiliary contact elements (side-marked symbol) except for NFZ33/11 and NFZ51/11 variants
–– overlapping of lagging / leading contacts for NFZ33/11 and NFZ51/11 variants
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 coils to cover control voltages between 24 ... 250 V 50/60 Hz and 12 ... 250 V DC
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
5
Ordering details
1st stack
Rated control circuit
voltage
Uc min. ... Uc max.
2nd stack
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
V DC
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
24...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
Order code
Weight
Pkg
(1 pce)
kg
NFZ44E-20
NFZ44E-21
NFZ44E-22
NFZ44E-23
NFZ53E-20
NFZ53E-21
NFZ53E-22
NFZ53E-23
NFZ62E-20
NFZ62E-21
NFZ62E-22
NFZ62E-23
NFZ71E-20
NFZ71E-21
NFZ71E-22
NFZ71E-23
NFZ80E-20
NFZ80E-21
NFZ80E-22
NFZ80E-23
8-pole contactor relays with overlapping of lagging / leading contacts
12...20
NFZ33/11-20
A1
41
13
23
33
51
61
75
87
NO NO NO NC NC NC NC NO
24...60
20...60
NFZ33/11-21
48...130
48...130
NFZ33/11-22
NO NO NO NC NC NC NC NO
14
24
34
42
52
62
76
88
A2
100...250
100...250
NFZ33/11-23
12...20
NFZ51/11-20
A1
43
13
23
33
53
61
75
87
NO NO NO NO NO NC NC NO
24...60
20...60
NFZ51/11-21
48...130
48...130
NFZ51/11-22
NO NO NO NO NO NC NC NO
14
24
34
44
54
62
76
88
A2
100...250
100...250
NFZ51/11-23
1SBH136001R2044
1SBH136001R2144
1SBH136001R2244
1SBH136001R2344
1SBH136001R2053
1SBH136001R2153
1SBH136001R2253
1SBH136001R2353
1SBH136001R2062
1SBH136001R2162
1SBH136001R2262
1SBH136001R2362
1SBH136001R2071
1SBH136001R2171
1SBH136001R2271
1SBH136001R2371
1SBH136001R2080
1SBH136001R2180
1SBH136001R2280
1SBH136001R2380
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
1SBH136001R2039
1SBH136001R2139
1SBH136001R2239
1SBH136001R2339
1SBH136001R2059
1SBH136001R2159
1SBH136001R2259
1SBH136001R2359
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the
coil terminals: A1+ for the positive pole and A2- for the negative pole
Main dimensions
mm, inches
110.5 4.35"
35 1.38"
2x
M4 8-32 UNC
70 2.76"
60 2.36"
6 0.24"
35 mm EN/IEC 60715
5.5 0.22"
ø 4.2 0.17"
1SBC101561S0201 - Rev. B
10 0.39"
5.5 0.22"
5 0.20"
71 2.80"
45 1.77"
80 3.15"
1SBC101043V0014
NFZ33/11
NFZ51/11
V 50/60 Hz
Type
8-pole contactor relays
43 1.69"
1SBC101042V0014
Number of contacts
5 0.20"
NFZ44E, NFZ53E, NFZ62E, NFZ71E, NFZ80E, NFZ33/11, NFZ51/11
ABB | 5/309
NF 8-pole contactor relays
Main accessories
Contactor relays and main accessories (other accessories available)
NF contactor relay
5
BX4-CA
Protective cover
2-pole CAL4-11
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor relay
types
Front-mounted accessories
Auxiliary contact blocks
Main
poles
Side-mounted accessories
Auxiliary contact blocks
1-pole CA4
4
5
6
7
8
3
5
4
3
2
1
0
3
1
E
E
E
E
E
/
/
4-pole CA4
–
–
Right side
2-pole CAL4-11
+
1
–
1 1
1 1
1SBC101598S0201 - Rev. B
NF
Left side
1-pole CC4
5/310 | ABB
NF 8-pole contactor relays
Main accessories
Ordering details (1)
1SBC101112F0014
For contactor relays
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Side-mounted instantaneous auxiliary contact blocks
NF
1SBC101133F0014
CAL4-11
LDC4
Auxiliary contacts
1 1
1 1
– –
– –
CAL4-11
CAL4-11-T
1SBN010120R1011
1SBN010120T1011
1
10
0.040
0.040
LDC4
1SBN070156T1000
10
0.010
BX4-CA
1SBN110109W1000
50
0.001
Additional coil terminal block
NF
Protective covers
NF
5
1SBC101138F0014
(1) For more information, refer to "Accessories" section.
1SBC101654S0201 - Rev. A
BX4-CA
ABB | 5/311
NF contactor relays
Technical data
Contact utilization characteristics according to IEC
AC / DC operated
Contactor relay types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith θ ≤ 40 °C
Ie / Rated operational current AC-15
24-127 V 50/60 Hz
acc. to IEC 60947-5-1
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
AC-15
Max. electrical switching frequency
DC-13
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
≥ 2 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4, CAL4 aux. contact blocks)
are mechanically linked contacts.
Contact utilization characteristics according to UL / CSA
AC / DC operated
Contactor relay types
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
NF
UL 508, CSA C22.2 N°14
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
1SBC101562S0201 - Rev. A
5
Rated making capacity AC-15
Rated breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
NF
IEC 60947-1 / 60947-5-1 and EN 60947-1 / 60947-5-1
690 V
50 / 60 Hz
16 A
5/312 | ABB
NF contactor relays
Technical data
General technical data
AC / DC operated
Contactor relay types
Rated insulation voltage Ui
acc. to IEC 60947-5-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor relay
Operation in free air
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
NF
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
20 millions operating cycles
6000 cycles/h
5
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
Shock direction
A
B1
B2
C1
C2
B2
C2
Vibration withstand
acc. to IEC 60068-2-6
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
30 g
25 g closed position / 5 g open position
15 g
25 g
25 g
5...300 Hz
4 g closed position / 2 g open position
Magnet system characteristics
Contactor relay types
Coil operating limits
NF
At θ
At θ
DC supply At θ
At θ
AC / DC operated
AC supply
acc. to IEC 60947-5-1
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Coil consumption
PLC-output control
Drop-out voltage
Voltage sag immunity
acc. to SEMI F47-0706
Dips withstand
-20 °C ≤ θ ≤ +60 °C
Operating time
Between coil energization and:
Between coil de-energization and:
Average pull-in value
Average holding value
Average pull-in value
Average holding value
≤
≤
≤
≤
60
70
60
70
°C
°C
°C
°C
0.85 x Uc min...1.1 x Uc max.
0.85 x Uc min...Uc max.
0.85 x Uc min...1.1 x Uc max.
(AF) 0.85 x Uc min...Uc max. - (NFZ) 0.85 x Uc min...1.1 x Uc max.
24...500 V AC
(NF) 50 VA - (NFZ) 16 VA
(NF) 2.2 VA / 2 W - (NFZ) 1.7 VA / 1.5 W
12...500 V DC
(NF) 50 W - (NFZ) 12...16 W
(NF) 2 W - (NFZ) 1.7 W
(NFZ) ≥ 500 mA 24 V DC
≤ 60 % of Uc min.
(NFZ) conditions of use on request
(NFZ) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DC
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
40...95
38...90
11...95
13...98
ms
ms
ms
ms
Mounting characteristics
Contactor relay types
Mounting positions
AC / DC operated
NF
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
Pos. 5
1SBC101563S0201 - Rev. A
Pos. 1
Max. add-on N.C. auxiliary contacts:
see accessory fitting details for a NF contactor relay
The contactor relays can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
ABB | 5/313
NF contactor relays
Technical data
Connecting characteristics
Contactor relay types
Main terminals
AC / DC operated
NF
Screw terminals with cable clamp
Connection capacity (min. ... max.)
Pole and coil terminals
Rigid
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
6
1 or 2 x
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Pole terminals
Coil terminals
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All terminals
Screw terminals
All terminals
AWG 18...14
10 mm
1.2 Nm / 11 lb.in
1.2 Nm / 11 lb.in
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SBC101564S0201 - Rev. A
5
Lugs
1x
2x
1x
2x
1x
2x
L<
5/314 | ABB
NF contactor relays
Terminal marking and positioning
Standard devices without addition of auxiliary contacts
13
A1
A2
21
31
13
43
A1
A2
21
33
43
13
NO NC NO NO
NO NC NC NO
A1
A2
23
33
43
13
NO NO NO NO
A1
A2
23
33
NO NO NO NO
51 61 71 81
NO NC NC NO
NO NC NO NO
NO NO NO NO
52 62 72 82
NO NO NO NO
14
14
14
14
32
A1
A2
44
NF..22E
13
22
34
A1
A2
44
NF..31E
A1
A2
23
33
43
13
24
34
A1
A2
44
NF..40E
A1
A2
23
33
43
13
24
34
A1
A2
A2
23
33
43
13
A1
A2
23
33
NO NO NO NO
53 61 73 83
NO NO NO NO
53 63 73 83
NO NC NC NC
NO NC NC NO
NO NC NO NO
NO NO NO NO
54 62 72 82
NO NO NO NO
54 62 72 84
NO NO NO NO
54 62 74 84
NO NO NO NO
54 64 74 84
NO NO NO NO
14
14
14
14
34
A2
44
NF..53E
13
24
34
A1
A2
44
A2
23
33
41
13
A1
A2
23
33
NO NO NO NO
53 61 75 87
NC NC NC NO
NO NC NC NO
52 62 76 88
NO NO NO NC
54 62 76 88
NO NO NO NO
14
14
24
34
A2
42
NF..33/11
A2
44
24
34
A1
A2
A2
NO
14
NC
22
NC
32
NO
44
24
34
A1
A2
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
NF..31E
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
NF..44E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
5
NF..53E
NF..62E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
44
NF..71E
NF..80E
NF..80E
A1
13
NO
23
NO
33
NO
41
NC
51
NC
61
NC
75
NC
87
NO
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
75
NC
87
NO
A2
NO
14
NO
24
NO
34
NC
42
NC
52
NC
62
NC
76
NO
88
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
76
NO
88
43
NO NO NO NC
51 61 75 87
A1
34
A1
NF..71E
NF..62E
A1
24
43
NO
43
NO NO NO NO
53 61 71 83
24
31
NC
NF..40E
NO NO NO NO
53 61 71 81
A1
21
NC
44
NF..44E
A1
13
NO
NF..22E
NC NC NC NC
22
A1
43
NF..51/11
NF..33/11
44
NF..51/11
Other possible contact combinations with auxiliary contacts added by the user
A1
A2
21
33
43
13
A2
21
33
13
43
NO NC NO NO
5-
NO NC NO NO
53
NO
A1
=
+
54
NO NC NO NO
5NO NC NO NO
14
14
22
34
A1
A2
44
22
34
A1
A2
A1
A2
23
33
+
A2
23
33
5- 6NO NO NO NO
14
14
CA4-10
A1
A2
23
33
NO NO NO NO
5- 6=
24
34
A1
A2
44
24
34
A2
NO NO NO NO
NC
NC
13
A1
A2
23
33
A2
23
33
=
+
54 62 72 84
NO NO NO NO
NO NO NO NO
14X
14X
14
14
14
34
A2
44
Combination 51
=
CAL4-11 +
24
34
A1
A2
NF..40E
44
24
34
A1
A2
44
-2
24
34
A1
A2
Combination 62 = NF..40E
61
71
83
NO NC NC NO
54
NO NO NO NO
24
NC
+
CA4-01+CA4-01
53
22X
NO
A1
21
NC
33
NO
43
NO
53
NO
A2
NO
14
NC
22
NO
34
NO
44
NO
54
Combination 41 E
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
Combination 42 E
A1
13
NO
23
NO
33
NO
43
NO
13X
NO
21X
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
14X
NC
22X
43
22X
NO NO NO NO NO
14
NC
-2
+
A1
-1
NO NO NO NO
NO NO NO NO
53 61 71 83
NO NC NC NO
+
13
43
13
NO
44
Combination 42 = NF..40E
43
-1
+
A1
A1
43
52 62
NO NO NO NO
NO
21X
NC
A1
-4
NO NO NO NO NO
21X
=
13
NC NC
13
NC
43
NO
13X
13
33
NO NO NO NO
51 61
43
13X
A2
23
-3
44
Combination 41 = NF..31E
A1
62
72
84
Combination 51 E
A1
13
NO
23
NO
33
NO
43
NO
53 61
NO NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO NC
54 62
NC
72
NO
84
44
+
CA4-22N
Combination 62 E
Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole
ABB | 5/315
1SBC101582S0201 - Rev. A
13
NF add-on auxiliary contacts
Terminal marking and positioning
1-pole auxiliary contacts
-1
-3
NO
NC
-4
-2
CA4-01
-5
-7
NO
NC
CA4-10
-8
-6
CC4-01
CC4-10
2-pole auxiliary contacts
31X
22X /
43X
CAL4-11
(Left side-mounted)
31X /
NC
32X /
21X
NC
43X /
NO
44X /
13X
44X
14X /
32X
21X /
NO
22X
13X /
14X
CAL4-11
(Right side-mounted)
4-pole auxiliary contacts
53
NO
54
61
71
81
NC
NC
NC
62
72
82
CA4-13N
53
NO
54
63
NO
73
NO
64
83
NO
84
74
CA4-40N
53
NO
54
61
73
NC NO
62
74
83
NO
84
CA4-31N
53
NO
54
61
71
NC
NC
62
72
83
NO
84
CA4-22N
51
61
71
81
NC
NC
NC
NC
52
62
72
82
CA4-04N
1SBC101582S0201 - Rev. A
5
5/316 | ABB
NF contactor relays
35 mm EN/IEC 60715
35 mm EN/IEC 60715
6 0.24"
80 3.15"
6 0.24"
80 3.15"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
5.5 0.22"
5.5 0.22"
10 0.39"
35 1.38"
2x
2x
ø 4.2 0.17"
M4 8-32 UNC M4 8-32 UNC
70 2.76"
71 2.80"
5.5 0.22"
5 0.20"
77 3.03"
71 2.80"
70 2.76"
77 3.03"
5 0.20"
45 1.77"
60 2.36"
45 1.77"
mm, inches
60 2.36"
Main dimensions
10 0.39"
5 0.20"
NF..22E, NF..31E, NF..40E
5 0.20"
NF
5
110.5 4.35"
71 2.80"
45 1.77"
77 3.03"
10 0.39"
12 0.47"
71 2.80"
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
5.5 0.22"
10 0.39"
NF..22E, NF..31E, NF..40E
+ CA4, CC4 1-pole auxiliary contact block
NF..22E, NF..31E, NF..40E
+ CAL4-11 2-pole auxiliary contact block
110.5 4.35"
110.5 4.35"
71 2.80"
45 1.77"
10 0.39"
35 1.38"
NF..44E, NF..53E, NF..62E, NF..71E, NF..80E, NF..33/11, NF..51/11
NF..22E, NF..31E, NF..40E
+ CA4 4-pole auxiliary contact block
60 2.36"
5.5 0.22"
ø 4.2 0.17"
43 1.69"
5.5 0.22"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
43 1.69"
80 3.15"
35 mm EN/IEC 60715
6 0.24"
5.5 0.22"
2x
M4 8-32
70 2.76"
10 0.39"
5 0.20"
133.5 5.26"
71 2.80"
45 1.77"
10 0.39"
1SBC101583S0201 - Rev. B
5.5 0.22"
40.5 1.59"
1.1 0.04"
35 mm EN/IEC 60715
80 3.15"
6 0.24"
5.5 0.22"
NF..22E, NF..31E, NF..40E
+ TEF4 electronic timer
Note: Contactor relay lateral distance to grounded component 2 mm 0.08" min.
ABB | 5/317
5 0.20"
71 2.80"
45 1.77"
Summary_5-8
5
5/318 | ABB
Accessories
Accessories for AF09 … AF2650 3-pole contactors,
AF09 ... AF370 4-pole contactors and NF contactor relays
5/321
Auxiliary contact blocks
5/322
Electronic timers
5/335
Interlocks
5/338
Impulse contact blocks
5/340
Mechanical latching units
5/342
Other accessories
5/344
Additional terminal blocks
5/346
Terminal shrouds
5/347
Connections
5/348
Terminal connecting strips and shorting bars
5/349
Connection accessories for starting solutions
5/350
Connection sets for star-delta starter
5/351
Connection bars
5/352
Mounting plates
5/353
Adapter plates
5/354
Contactor coils, main contact sets and arc chutes
5/355
Accessories for UA, UA..RA, GA75, GAE75, GAF contactors
5/357
Auxiliary contact blocks
5/358
Electronic timers
5/365
Mechanical and electrical interlock units
5/368
CA5, CE5, CAL5 and TEF5 fitting details
5/370
Function markers - Mounting piece
5/371
Surge suppressors for contactor coils
5/372
Interface relays
5/374
Mechanical latching units
5/376
Additional terminal blocks and others accessories
5/378
Terminals for control lead connections
5/379
Contactor coils and main contact sets
5/380
Accessories for EK550, EK1000 4-pole contactors
5/381
Auxiliary contact blocks
5/382
5
Mechanical interlock units, terminal shrouds and connection sets 5/386
5/388
Main contact sets - Arc chutes
5/390
Contactor coils
5/391
Summary_5-8
Surge suppressors for contactor coils
ABB | 5/319
Summary_5-9
5
5/320 | ABB
Accessories for AF09 … AF2650 3-pole contactors,
AF09 ... AF370 4-pole contactors and NF contactor relays
Auxiliary contact blocks
5/322
Electronic timers
5/335
Interlocks
5/338
Impulse contact blocks
5/340
Mechanical latching units
5/342
Other accessories
5/344
Additional terminal blocks
5/346
Terminal shrouds
5/347
Connections
5/348
Terminal connecting strips and shorting bars
5/349
Connection accessories for starting solutions
5/350
5/351
Connection bars
5/352
Mounting plates
5/353
Adapter plates
5/354
Contactor coils, main contact sets and arc chutes
5/355
5
Summary_5-9
Connection sets for star-delta starter
ABB | 5/321
Auxiliary contact blocks for AF09 ... AF96 contactors and
NF contactor relays
Description
1SBC100001V0014
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard
industrial environments.
Types of auxiliary contact blocks for front mounting:
–– CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts
–– CC4 1-pole block, with N.O. leading contact or N.C. lagging contact
–– CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connection on
front face.
1SBC100007V0014
CA4-10
Types of auxiliary contact blocks for side mounting:
–– CAL4 2-pole block, with instantaneous N.O. + N.C. contacts.
For clipping onto the right- and/or left-hand side of the contactors.
CAL4-11
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact and bear the corresponding function marking.
1SBC100006V0014
5
Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the
contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and
positioning").
Ordering details (1)
For contactors
Auxiliary contacts
Type
Order code
Pkg
qty
1SBC100002V0014
CAT4-11E
Front-mounted instantaneous auxiliary contact blocks
AF09 ... AF96
1 0
– –
CA4-10
4-pole NF
1 0
– –
CA4-10-T
0 1
– –
CA4-01
0 1
– –
CA4-01-T
AF09 ... AF16..-30-10
2 2
– –
CA4-22M
3 1
– –
CA4-31M
1 3
– –
CA4-13M
0 4
– –
CA4-04M
AF26 ... AF96..-30-00
2 2
– –
CA4-22E
AF09 ... AF80..-40-00
3 1
– –
CA4-31E
AF09 ... AF80..-22-00
4 0
– –
CA4-40E
AF26 ... AF96..-30-00
0 4
– –
CA4-04E
AF09 ... AF16..-40-00
AF40 ... AF80..-40-00
AF09 ... AF16..-30-01
2 2
– –
CA4-22U
3 1
– –
CA4-31U
4 0
– –
CA4-40U
4-pole NF
2 2
– –
CA4-22N
3 1
– –
CA4-31N
4 0
– –
CA4-40N
1 3
– –
CA4-13N
NF..40E
0 4
– –
CA4-04N
1SBN010110R1010
1SBN010110T1010
1SBN010110R1001
1SBN010110T1001
1SBN010140R1122
1SBN010140R1131
1SBN010140R1113
1SBN010140R1104
1SBN010140R1022
1SBN010140R1031
1SBN010140R1040
1SBN010140R1004
1
10
1
10
1
1
1
1
1
1
1
1
0.014
0.014
0.014
0.014
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
1SBN010140R1322
1SBN010140R1331
1SBN010140R1340
1SBN010140R1222
1SBN010140R1231
1SBN010140R1240
1SBN010140R1213
1SBN010140R1204
1
1
1
1
1
1
1
1
0.055
0.055
0.055
0.055
0.055
0.055
0.055
0.055
Front-mounted auxiliary contact blocks with N.O. leading contact and N.C. lagging contact
AF09 ... AF96
– –
1 0
CC4-10
1SBN010111R1010
1
4-pole NF
– –
0 1
CC4-01
1SBN010111R1001
1
0.014
0.014
Side-mounted instantaneous auxiliary contact blocks
AF09 ... AF96
1 1
– –
CAL4-11
NF
1 1
– –
CAL4-11-T
1
10
0.040
0.040
Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks
AF09 ... AF16..-30-10
1 1
– –
CAT4-11M
1SBN010151R1111
AF26 ... AF65..-30-00
1 1
– –
CAT4-11E
1SBN010151R1011
AF09 ... AF52..-40-00
AF09 ... AF40..-22-00
1
1
0.040
0.040
AF09 ... AF16..-30-01
1
0.040
1 1
– –
CAT4-11U
1SBN010120R1011
1SBN010120T1011
1SBN010151R1311
(1) For each contactor or contactor relay type, refer to "Accessory fitting details" table.
Note: CAT4 not suitable for AF..Z contactors with DC control voltage 12…20 V DC.
1SBC101573S0201 - Rev. A
kg
CA4-22E
5/322 | ABB
Weight
(1 pce)
Auxiliary contact blocks for AF09 ... AF96 contactors and
NF contactor relays
Technical data
Contact utilization characteristics according to IEC
Types
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp.
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Rated frequency (without derating)
Ie / Rated operational current AC-15
24-127 V 50/60 Hz
acc. to IEC 60947-5-1
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
for 1.0 s
for 0.1 s
AC-15
DC-13
Mechanically linked contacts acc. to annex L of IEC 60947-5-1
Mirror contacts acc. to annex F of IEC 60947-4-1
1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
24...690 V
16 A
50/60 Hz
6A
4A
3A
2A
2A
10 x Ie AC-15
10 x Ie AC-15
5
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
0.1 W
10 millions operating cycles
3600 cycles/h
1200 cycles/h
900 cycles/h
Additional N.O. or N.C. auxiliary contacts (CA4, CAL4, CAT4) are mechanically linked contacts
Additional N.C. auxiliary contacts (CA4, CAL4, CAT4) are mirror contacts
Contact utilization characteristics according to UL / CSA
1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4
UL 508, CSA C22.2 N°14
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
Types
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Connecting characteristics
Types
Connection capacity (min. ... max.)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
L
Lugs
1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4
1x
2x
1x
2x
1x
2x
L<
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
6
AWG 18...14
10 mm
1.2 Nm / 11 lb.in
1SBC101593S0201 - Rev. A
1 or 2 x
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
ABB | 5/323
Auxiliary contact blocks for severe industrial environments
for AF09 ... AF96 contactors and NF contactor relays
1SBC101030V0014
Description
CE5-10W
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for severe
industrial environments.
Types of auxiliary contact blocks for front mounting:
–– CE5 1-pole block, instantaneous with N.O. contact or N.C. contact, available in 2 IP degrees
-- CE5
D with built-in microswitch IP40, degree of protection (IP20 on terminals)
-- CE5
W with built-in microswitch IP67, degree of protection (IP20 on terminals).
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protectedagainst accidental direct contact and bear the corresponding function marking.
Ordering details (1)
For contactors
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
CE5-10D0.1
CE5-01D0.1
CE5-10D2
CE5-01D2
CE5-10W0.1
CE5-01W0.1
CE5-10W2
CE5-01W2
1SBN010015R1010
1SBN010015R1001
1SBN010017R1010
1SBN010017R1001
1SBN010016R1010
1SBN010016R1001
1SBN010018R1010
1SBN010018R1001
1
1
1
1
1
1
1
1
kg
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
5
AF09 ... AF96
NF
1
–
1
–
1
–
1
–
–
1
–
1
–
1
–
1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
(1) For each contactor type, refer to "Accessory fitting details" table.
mm, inches
47 1.85"
A
5/324 | ABB
1-pole CE5 on
AF09 ... AF16..-30-xx 1 stack
AF09, AF16..-40/22-00
NF..E 1-stack
AF26 ... AF38..-30-00
AF26, AF38..-40/22-00
AF40 ... AF65-30-00
AF40 ... AF65-40/22-00
AF80 ... AF96-30-00
AF80-40/22-00
A
103.5 mm / 4.07"
112.5 mm / 4.43"
127.5 mm / 5.02"
137 mm / 5.39"
140 mm / 5.51"
142 mm / 5.59"
142 mm / 5.59"
1SBC101905S0201 - Rev. A
Main dimensions
Auxiliary contact blocks for severe industrial environments
Technical data
Front mounted
1-pole CE5-..0.1
Types
1-pole CE5-..2
Contact utilization characteristics according to IEC
Standards
Rated insulation voltage Ui
acc. to IEC 60947-5-1
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Rated frequency (without derating)
Ie / Rated operational current
24-127 V 50/60 Hz
acc. to IEC 60947-5-1
Making capacity
Breaking capacity
Ie / Rated operational current DC-12
acc. to IEC 60947-5-1
IEC 60947-5-1 and EN 60947-5-1
250 V
125 V
0.1 A
50 / 60 Hz
AC-14
0.1 A
220-240 V 50/60 Hz –
6 x Ie AC-14 acc. to IEC 60947-5-1
6 x Ie AC-14 acc. to IEC 60947-5-1
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
Short-circuit protection device FF type fuse (1)
Minimum switching capacity
AF09 … AF38 contactors
with failure rate acc. to IEC 60947-5-4
Mechanical durability
Number of operating cycles
Max. switching frequency
Electrical durability
Number of operating cycles
0.1
0.1
0.1
0.1
–
–
0.1
A
A
A
A
A
250 V
2A
AC-15
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
5
2A
1A
0.3 A
0.2 A
0.2 A
0.1 A
10 A
3 V / 1 mA
–
17 V / 1 mA
≤ 10-7
5 millions for CE5-..D0.1
2.5 millions for CE5-..W0.1
3600 cycles/h
5 millions for CE5-..D2
2.5 millions for CE5-..W2
2.5 millions for CE5-..D0.1
0.7 millions for CE5-..W0.1
1 million for CE5-..D2
0.3 millions for CE5-..W2
Max. electrical switching frequency
AC-14
AC-15
DC-12
1200 cycles/h
1200 cycles/h
900 cycles/h
Contact utilization characteristics according to UL / CSA
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
UL 508, CSA C22.2 N°14
125 V AC / 110 V DC
250 V AC / 220 V DC
0.1 A
2A
Connecting characteristics
Flexible with ferrule
l L
Lugs
Connecting capacity acc. to UL / CSA
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and
IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
7.7 mm
3.7 mm
AWG 18...14
1 Nm
Terminals IP20
Microswitches IP40 for CE5-..D0.1
IP40 for CE5-..D2
IP67 for CE5-..W0.1
IP67 for CE5-..W2
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1x
2x
1x
2x
L≤
l>
1 or 2 x
1SBC101906S0201
Connection capacity (min. ... max.)
Rigid solid
(1) HRC fuses for very fast action (6.3 x 32 mm size).
ABB | 5/325
Auxiliary contact blocks for severe industrial environments
For AF contactors
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Auxiliary contact blocks
1-pole CE5
Side-mounted accessories
Electrical and
Auxiliary contact blocks
mechanical interlock set
1-pole CA4
(Between 2 contactors)
Left side
1-pole CC4
VEM4
2-pole CAL4-11
Right side
3-pole contactors AF09 ... AF38
Max. N.C. built-in and add-on N.C. auxiliary contacts (CA4, CC4, CAL4, VEM4):
2 max. with 1 CE5, none with 2 CE5 on positions 1, 2, 3, 4
3 0
3 0
3 0
0 1
1 0
0 0
1
2
1
1
1
+
+
+
+
+
3
2
3
1
2
max.
max.
max.
max.
max.
–
–
–
–
+ 1
+ 1
–
+ 1
+ 1
+ 1
+
–
–
–
1
–
Max. N.C. built-in or add-on N.C. auxiliary contacts (CA4, CC4, CAL4, VEM4):
1 max. with 1 CE5 on positions 1 ±30°, 5
AF09 ... AF16
AF09 ... AF16
AF26 ... AF38
3 0
3 0
3 0
0 1
1 0
0 0
1
1
1
+
+
+
3 max.
3 max.
2 max.
–
–
+ 1
–
+ 1
–
–
–
–
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4):
4 max. with 1 CE5, 2 max. with 2 CE5 on positions 1, 1 ±30°, 2, 3, 4, 5
AF40 ... AF96
3 0
0 0
2
1
+
+
–
–
+ 1
+ 1
–
–
–
+ 1
–
+ 1
+ 1
+ 1
2 max.
3 max.
+
+
1
1
4-pole contactors AF09 ... AF80
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4, VEM4):
2 max. with 1 CE5, none with 2 CE5 on positions 1, 2, 3, 4
AF09, AF16
4 0
0 0
2
1
1
1
+
+
+
+
2
3
1
2
max.
max.
max.
max.
+
–
–
1
–
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4, VEM4):
1 max. with 1 CE5 on positions 1, 2, 3, 4
AF26, AF38
4 0
0 0
AF09, AF16
AF26, AF38
2 2
0 0
1
1
1
+
+
+
3 max.
2 max.
3 max.
–
+ 1
–
+ 1
–
+ 1
–
–
–
–
+ 1
+ 1
–
–
–
–
–
–
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4, VEM4):
1 max. with 1 CE5 on positions 1 ±30°, 5
AF09, AF16
4 0
0 0
AF26, AF38
AF09, AF16
AF26, AF38
4 0
2 2
2 2
0 0
0 0
0 0
1
1
+
+
3 max.
2 max.
No add-on N.C. auxiliary contacts on positions 1 ±30°, 5
1
+
3 max.
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4):
4 max. with 1 CE5, 2 max. with 2 CE5 on positions 1, 1 ±30°, 2, 3, 4, 5
AF40 ... AF80
4 0
0 0
AF40, AF80
2 2
0 0
2
1
+
+
2 max.
3 max.
–
–
+ 1
+ 1
+
+
1
1
No add-on N.C. auxiliary contacts on positions 1, 1 ±30°, 2, 3, 4, 5
1
+
3 max.
–
–
–
1SBC101907S0201 - Rev. A
5
AF09 ... AF16
AF09 ... AF16
AF26 ... AF38
5/326 | ABB
Auxiliary contact blocks for severe industrial environments
For NF contactor relays
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor relay
types
Main
poles
Front-mounted accessories
Auxiliary contact blocks
1-pole CE5
Side-mounted accessories
Auxiliary contact blocks
1-pole CA4
Left side
1-pole CC4
2-pole CAL4-11
Right side
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4): 1 max. with 1 CE5 on positions 1, 2, 3, 4
NF
2 2
3 1
E
E
1
+
NF
4 0
E
2
1
1
+
+
+
3 max.
–
+
1
–
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4): 2 max. with 1 CE5, none with 2 CE5 on positions 1, 2, 3, 4
2 max.
3 max.
1 max.
–
–
–
+
+
–
1
1
+
–
–
1
5
Max. add-on N.C. auxiliary contacts (CA4, CC4): none with 1 CE5 on positions 1 ±30°, 5
NF
2 2
3 1
E
E
1
+
NF
4 0
E
1
+
3 max.
–
–
–
Max. add-on N.C. auxiliary contacts (CA4, CC4, CAL4): 1 max. with 1 CE5 on positions 1 ±30°, 5
–
+
1
–
1SBC101907S0201 - Rev. A
3 max.
ABB | 5/327
Auxiliary contact blocks for AF116 ... AF2650 contactors
1SFC101071V0001
Description
CAL19-11
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard
industrial environments.
Types of auxiliary contact blocks for side mounting:
– – CAL 2-pole block, with instantaneous N.O. + N.C. contacts.
For clipping onto the right- and/or left-hand side of the contactors.
The CAL ...-11B is a second block for mounting in addition to a first CAL ...-11 block, right- and/or lefthand of the AF116 ... AF2650 contactors.
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact and bear the corresponding function marking.
Ordering details
For contactors
Auxiliary Type
contacts
Order code
Pkg
qty
5
Weight
(1 pce)
1SFC101082V0001
kg
CAL18-11
Side-mounted instantaneous auxiliary contact blocks
AF116 ... AF370
AF400 ... AF2650
1
1
1
1
1
1
1
1
CAL19-11
CAL19-11B
CAL18-11
CAL18-11B
1SFN010820R1011
1SFN010820R3311
1SFN010720R1011
1SFN010720R3311
2
2
2
2
0.040
0.040
0.050
0.050
1SFC101097C0201
(1) For each contactor type, refer to "Accessory fitting details" table.
5/328 | ABB
Auxiliary contact blocks for AF116 ... AF2650 contactors
Technical data
Types
CAL18
CAL19
Contact utilization characteristics according to IEC
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp.
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Rated frequency (without derating)
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
24...690 V AC
16 A
50/60 Hz
24-127 V 50/60 Hz
220-240 V 50/60 Hz
380-440 V 50/60 Hz
500-690 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
for 1.0 s
for 0.1 s
AC-15
DC-13
Mechanically linked contacts acc. to annex L of IEC 60947-5-1
Mirror contacts acc. to annex F of IEC 60947-4-1
6A
4A
3A
2A
10 x Ie AC-15
10 x Ie AC-15
5
6 A / 144 W
3 A / 72 W
2.8 A / 134 W
1.5 A / 72 W
1 A / 72 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 60 W
0.55 A / 69 W
0.55 A / 69 W
0.3 A / 66 W
0.3 A / 69 W
0.3 A / 75 W
0.3 A / 75 W
10 A
100 A
140 A
24 V / 50 mA (0.5 million of operating cycles)
24 V / 50 mA
≤ 10-6
0.15 W
3 millions (A/AF400 ... AF750)
0.5 million (AF1250 ... AF2050)
5 millions operating cycles
3600 cycles/h
300 cycles/h
1200 cycles/h
300 cycles/h
900 cycles/h
300 cycles/h
N.O. or N.C. auxiliary contacts are mechanically linked contacts
N.C. auxiliary contacts are mirror contacts
Contact utilization characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
600 V AC, 250 V DC
A600, Q300
10 A
7200 V A
720 V A
2.5 A
69 V A
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Connecting characteristics
1x
2x
1x
2x
1x
Flexible with non insulated ferrule
Flexible with insulated ferrule
2x
l L
Lugs
L≤
l>
1 or 2 x
Connection capacity acc. to UL/CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.7 mm
AWG18...14
9 mm
1 Nm
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1SFC101116C0201
Connection capacity (min. ... max.)
Solid / stranded
ABB | 5/329
Auxiliary contact blocks for AF400 ... AF2650 contactors
for severe industrial environments
1SFC101083V0001
Description
CEL18
The auxiliary contact blocks are used for the operation of auxiliary and control circuits for severe industrial
environments.
Types of auxiliary contact blocks for side mounting:
–– CEL18 1-pole block, with built-in microswitch IP67 degree of protection (IP20 on terminals).
Instantaneous N.O. or N.C. contact.
For clipping onto the right- and/or lef-thand side of the contactors.
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact and bear the corresponding function marking.
Ordering details (1)
For contactors
Auxiliary
contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
5
Side-mounting instantaneous auxiliary contact blocks
AF400 ... AF2650
1
0 CEL18-10
0
1 CEL18-01
1SFN010716R1010
1SFN010716R1001
1
1
0.050
0.050
1SFC101125C0201
(1) For each contactor type, refer to "Accessory fitting details" table.
5/330 | ABB
Auxiliary contact blocks for AF400 ... AF2650 contactors
for severe industrial environments
Technical data
Types
CEL18
Contact utilization characteristics according to IEC
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-14
acc. to IEC 60947-5-1
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-12
acc. to IEC 60947-5-1
Short-circuit protection device
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Mechanical durability
Number of operating cycles
Max. switching frequency
Electrical durability
Number of operating cycles
Max. switching frequency
IEC 60947-5-1 and EN 60947-5-1
250 V
125 V
0.1 A
24-127 V 50/60 Hz
24 V DC
48 V DC
72 V DC
110 V DC
220 V DC
0.1 A
6 x Ie AC-14
6 x Ie AC-14
0.1
0.1
0.1
0.1
–
0.1
A
A
A
A
5
A (FF type fuses) (1)
3 V / 1 mA
1 million
1200 cycles/h
0.7 millions
AC-14, AC15 1200 cycles/h
DC-12 900 cycles/h
Contact utilization characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
125 V
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
0.1 A
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
1...4 mm²
1...4 mm²
Flexible with ferrule
0.75...2.5 mm²
0.75...2.5 mm²
Lugs
7.7 mm
l L
3.7 mm
Connection capacity acc. to UL/CSA
1 or 2 x AWG 18...14
Tightening torque
1 Nm
Terminals IP20
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 Microswitches IP67
Screw terminals
Delivered in open position, screws of unused terminals must be tightened
All terminals
M3.5
Screwdriver type
Flat Ø 5.5 / Pozidriv 2
1x
2x
1x
2x
L≤
l>
1SFC101129C0201
(1) or HRC fuses for very fast action (6.3 x 32 mm size).
ABB | 5/331
Auxiliary contact blocks for AF09 ... AF96 contactors and
NF contactor relays
Electrical durability
Electrical durability for AC-15 utilization category
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
These curves represent the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.
The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.
30
20
–– AF09 ... AF96 contactor built-in auxiliary contacts
–– 1-pole and 4-pole CA4, 2-pole CAT4,
1-pole CC4,
2-pole CAL4 add-on auxiliary contacts.
10
3
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2
3 4 5 6
10
Example:
Breaking current = 1 A
On the opposite curve at intersection "O" 1 A the
corresponding value for the electrical durability is approximately 2 millions operating cycles.
Breaking current (A)
30
20
NF contactor relays.
(For add on auxiliary contacts see curve above).
10
Million operating cycles
5
3
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2
3 4 5 6
10
Breaking current (A)
Electrical durability for DC-13 utilization category
DC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1: making and breaking current Ie and Ue.
100
70
50
6
1.10 cycles
6
3.10 cycles
– – AF09 ... AF96 contactor built-in auxiliary contacts
1-pole and 4-pole CA4, 2-pole CAT4, 1-pole CC4,
– – 2-pole CAL4 add-on auxiliary contacts,
– – NF contactor relays.
20
6
10.10 cycles
10
5
2
1
10
20 24
50
72
100
200 250
Voltage (V)
5/332 | ABB
500
Example:
Control of DC electro-magnet:
Ue voltage = 72 V DC and breaking power = 70 W.
On the opposite curve at intersection "O" 72 V / 70 W the
corresponding value for the electrical durability is approximately 2 millions operating cycles.
1SBC101641S0201 - Rev. A
Breaking power (W)
5
Million operating cycles
5
Auxiliary contacts for AF116 ... AF2650 contactors
Electrical durability
Electrical durability for AC-15 utilization category
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
– – making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
This curves represent the electrical durability of the add-on auxiliary contacts, in relation to the breaking current.
The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.
30
20
––
––
10
2.7
Example:
Breaking current = 1.2 A
On the opposite curve at intersection "O" 1.2 A the
corresponding value for the electrical durability is
approximately 2.7 millions operating cycles.
3
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2 3 4 5 6
1.2
Breaking current (A)
5
10
1SFC101117C0201
Million operating cycles
5
AF116 ... AF2650 contactors auxiliary contacts
2-pole CAL18 and CAL19 add-on auxiliary contacts
ABB | 5/333
Add-on auxiliary contacts
Terminal marking and positioning
1-pole auxiliary contacts
-1
-5
-3
NO
NC
-2
-8
-6
-4
CA4-01
-7
NO
NC
CA4-10
CC4-01
CC4-10
2-pole auxiliary contacts
54X /
13X
21X
31X
CAL18-11, CAL19-11
(Right-side mounted)
83X
44X /
61X /
71X /
NC
NO
62X /
-2
-4
CAT4-11U
83X /
NO
NC
72X /
71X
53X /
-1
NC
CAL18-11B, CAL19-11B
(Left-side mounted)
61X
32X
32X /
44X
43X
CAL18-11, CAL19-11
(Left-side mounted)
22
CAT4-11E
NO
NC
-3
NO
84X /
53X
22X
22X /
43X /
14X
14X /
31X /
NC
21
NC
14
CAT4-11M
84X
21X /
NO
34
22
CAL4-11
(Right-side mounted)
13
NO
72X
43X
13X /
44X /
33
NO
62X
31X
32X /
CAL4-11
(Left-side mounted)
21
NC
NO
21X
22X /
43X /
NC
54X
NC
13X
44X
14X /
31X /
32X
21X /
NO
22X
13X /
14X
CAL18-11B, CAL19-11B
(Right-side mounted)
4-pole auxiliary contacts
13
NO
14
23
NO
33
NO
24
43
NO
34
44
CA4-40E
13
NO
14
21
NC
22
33
NO
34
13
14
21
31
NC
NC
22
32
31
41
NC
NC
NC
22
32
42
53
NO
54
CA4-13M
43
NO
44
CA4-31E
NO
21
21
NC
22
33
NO
34
43
NO
44
43
44
CA4-22E
21
31
NC
NC
22
32
43
NO
44
53
NO
54
53
NO
54
4
3
NO
4
3
NO
4
1
NC
3
2
3
NO
4
21
31
41
21
31
41
51
NC
NC
NC
NC
NC
NC
NC
NC
12
22
32
42
22
32
42
52
53
NO
4
54
61
71
81
NC
NC
NC
62
72
82
CA4-13N
NO
4
3
NO
53
NO
4
54
73
63
NO
NO
64
84
74
1
1
NC
2
2
3
NO
4
53
NO
54
61
73
NC NO
62
74
83
NO
84
CA4-31N
53
NO
54
61
71
NC
NC
62
72
83
NO
84
CA4-22N
51
61
71
NC
NC
NC
NC
52
62
72
82
CA4-04N
5/334 | ABB
83
NO
CA4-40N
NC
CA4-22U
11
CA4-04M
3
NO
CA4-31U
CA4-22M
CA4-04E
4
3
NO
CA4-40U
CA4-31M
NO
3
NO
81
1SBC101660S0201 - Rev. A
5
Electronic timers
1sbc100004V0014
Description
TEF4-ON
TEF4 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFFdelay versions.
Compact solution in cabinet compared to separate timers
TEF4 electronic timers are front-mounted and locked on AF contactors or NF contactor relays.
A mechanical indicator allows to show the state of the contactor.
Safe and cost-reduced wiring
TEF4 electronic timers are supplied by a direct plug-in parallel connection to the coil terminals A1 - A2 of
the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against
surges in the contactor coil.
Available for a wide control voltage range 24...240 V AC/DC
TEF4-ON or TEF4-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently
of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted
by means of a rotary switch. The timing function is activated by closing or opening the device on which the
timer is mounted. The OFF-delay version operates without additional control supply.
5
TEF4-OFF
For contactors,
contactor relays
Time delay
range
Delay
type
selected by
switch
Rated control
circuit voltage
Uc
Auxiliary Type
contacts
Order code
Pkg
(1 pce)
24...240
1
1
TEF4-ON
1SBN020112R1000
kg
0.065
OFF-delay 24...240
1
1
TEF4-OFF 1SBN020114R1000
0.065
V 50/60 Hz or DC
AF09 ... AF96
NF
0.1...1 s
1...10 s
10...100 s
Weight
ON-delay
1SBC101669S0201 - Rev. A
1SBC100012V0014
Ordering details
ABB | 5/335
Electronic timers
Technical data
Contact utilization characteristics according to IEC
Types
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 3 A
Function diagram
TEF4-OFF
3 A
1.5 A
10 x Ie AC-15
10 x Ie AC-15
1 A / 24 W
6 A
for 1.0 s 8 A
for 0.1 s 8 A
12 V / 3 mA
24 V DC 10-7
0.1 W
ON-delay
24 V DC
OFF-delay
150 ms
min.
Uc (A1 - A2)
1s
min.
Uc (A1 - A2)
100 ms
min.
100 ms
min.
N.O. (67 - 68)
N.O. (67 - 68)
N.C. (55 - 56)
N.C. (55 - 56)
t
t
Bistable relay inside.
Before use, once apply Uc then switch it off in order to initialize position of the contacts.
Control circuit voltage
AC control voltage
50/60 Hz
DC control voltage
Rated control circuit voltage Uc
Average consumption
Rated control circuit voltage Uc
Average consumption
Rated frequency limits
Supply voltage range
Overvoltage protection
Time delay range (t) selected by switch
24...240 V AC
1.5 mA RMS
24...240 V DC
1.5 mA
50 / 60 Hz
0.85...1.1 x Uc (at θ ≤ 70 °C)
Varistor included
1 mA
0.1...1 s
1...10 s
10...100 s
On-load reiteration accuracy under constant conditions
Minimum ON period
Recovery time
Ambient air temperature Operation
Storage
Climatic withstand
Maximum operating altitude
Mounting positions
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
(Mounting position 1)
Vibration withstand
acc. to IEC 60068-2-6
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
≤1%
0.1 s
1 s
0.15 s
0.1 s
-25 °C ... +70 °C
-40 °C ... +80 °C
Category B according to IEC 60947-1 Annex Q
2000 m
Mounting positions 1, 1 +/- 30°, 2, 3, 4, 5
1/2 sinusoidal shock for 11 ms: no change in contact position
Same as contactor or contactor relay
5...300 Hz
3 g closed position / 2 g open position
5 millions operating cycles
3600 cycles/h
AC-15
DC-13
5/336 | ABB
1 mA RMS
1200 cycles/h
900 cycles/h
1800 cycles/h
1SBC101670S0201 - Rev. A
5
TEF4-ON
IEC 60947-5-1 and EN 60947-5-1
400 V
4 kV
240 V
50 / 60 Hz
5 A
Electronic timers
Technical data
Contact utilization characteristics according to UL / CSA
Types
Standards
Rated insulation voltage Ui acc. to UL / CSA
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
TEF4-ON
UL 508, CSA C22.2 N°14
300 V
240 V
B300, R300
5A
3600 VA
360 VA
1A
28 VA
TEF4-OFF
Connecting characteristics
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
Terminal Marking
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
3.7 mm
AWG 18...14
10 mm
1.2 N.m / 11 lb.in
5
IP20
Delivered in open position, screws of unused terminals should be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
A1
55 NC
67 NO
KM1
A2
A1
55 NC
67 NO
56 NC
68 NO
KM1
56 NC
68 NO
A2
1SBC101670S0201 - Rev. A
Connection capacity (min. ... max.)
Rigid solid
ABB | 5/337
1SBC100010V0014
Interlocks
Mechanical interlock units
Description
The VM mechanical interlock units are designed for the interlocking of two AF contactors.
When mounted between two contactors, the VM mechanical interlock unit prevents one of the contactors
from closing as long as the other contactor is closed.
The mechanical interlock units VM4 and VM96-4 include 2 fixing clips (BB4).
VM4
Ordering details
For contactors
Type
Order code
Mechanical interlock units for two contactors mounted side by side
AF09 ... AF38..-30-..
VM4
1SBN030105T1000
AF09 ... AF38..-40-00
AF40 ... AF96-30-..
VM96-4
1SBN033405T1000
AF40 ... AF80-40-00
For same size contactors:
VM19
1SFN030300R1000
AF116 ... AF146
AF190, AF205
AF265 ... AF370
VM140/190
1SFN034403R1000
AF116 ... AF146 and
AF190, AF205
AF190, AF205 and
VM205/265
1SFN035203R1000
AF265 ... AF370
AF400 ... AF1250
PN.. mounting plate to be ordered
VM750H
1SFN035700R1000
separately
AF1350 ... AF2650
Plate included
VM1650H
1SFN036503R1000
1SFC101035V0014
5
Mounting
VM19
Mechanical interlock units for two contactors mounted one above the other
AF400 ... AF1250
Additional plate (not supplied)
VM750V
1SFN035701R1000
Pkg
qty
Weight
(1 pce)
kg
10
0.005
10
0.006
1
0.054
1
0.088
1
0.090
1
0.200
1
6.000
1
0.200
Mechanical and electrical interlock sets
1SBC100011V0014
Description
VEM4
Ordering details
01NC
For contactors
KM1
Auxiliary Type
contacts
Order code
Pkg
qty
KM2
A2
1SBC100013V0014
VEM4
BB4
5/338 | ABB
Weight
(1 pce)
kg
A2
Mechanical and electrical interlock set
For same size contactors:
AF09 ... AF16..-30-..
AF26 ... AF38..-30-00
AF09, AF16..-40-00
AF26, AF38..-40-00
Fixing clips
AF09 ... AF96
0 2
VEM4
1SBN030111R1000
1
0.035
BB4
1SBN110120W1000
50
0.002
Note: VEM4 not suitable for AF..Z contactors with DC control voltage 12...20 V DC.
1SBC101595S0201 - Rev. A
01 NC
VEM4 mechanical and electrical interlock set for the interlocking of two AF contactors.
VEM4 set includes a mechanical interlock unit VM4 with 2 fixing clips (BB4) and a VE4 electrical interlock
block with A2-A2 connection.
Fixing the electrical interlock block to the contactor front face connects the 2 built-in N.C. interlocking contacts with the two coils. VE4 block must be used with A2-A2 connection to respect the electrical connection
diagram.
Interlocks
Technical data
Mechanical interlock unit
Types
Mechanical durability Number of operating cycles
Max. mechanical switching frequency
VM4, VM96
5 millions operating cycles
1800 cycles/h
VM19 ... VM750
1 million operating cycles
300 cycles/h
VM1650H
500 000 operating cycles
Mechanical and electrical interlock set
Contact utilization characteristics according to IEC
Types
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp.
Rated control circuit voltage Uc
VEM4
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
AC 50/60 Hz control voltage
DC control voltage
Conventional thermal current Ith - θ ≤ 40 °C
Mechanical durability Number of operating cycles
Max. mechanical switching frequency
Electrical durability
Max. electrical switching frequency
5
24...500 V AC
20...500 V DC
16 A
5 millions operating cycles
1800 cycles/h
1200 cycles/h
Contact utilization characteristics according to UL / CSA
Types
Standards
Max. operational voltage
VEM4
UL 508, CSA C22.2 N°14
500 V AC, 500 V DC
Connecting characteristics
Types
Connection capacity (min. ... max.)
Rigid solid
Flexible with ferrule
Flexible with insulated ferrule
L
Lugs
VEM4
1x
2x
1x
2x
1x
2x
L<
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
6
AWG 18...14
10 mm
1.2 Nm / 11 lb.in
IP20
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1SBC101594S0201 - Rev. A
1 or 2 x
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
ABB | 5/339
Impulse contact blocks
1SBC100039V0014
Description
CB5
Impulse contact blocks are designed for use in enclosures, in association with an adjustable mechanical
pushbutton. Two types are available:
–– CB5-10: N.O. contact with a black actuator ("ON" function)
–– CB5-01: N.C. contact with a light grey actuator ("OFF" function).
These blocks are equipped with 2 connecting leads 0.5 mm2 with end, approximately 18 cm long.
Mounting: Clipped onto the front face of the contactors.
Ordering details
For contactors
Contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
5
AF09 ... AF38
1
–
–
1
CB5-10
CB5-01
1SBN010013R1010
1SBN010013R1001
1
1
0.012
0.012
Note: For AF40 ... AF96 mounting: please consult us.
22.9 0.90"
10 0.39"
9.8
0.39"
CB5-10
5/340 | ABB
21.6 0.85"
36 1.42"
36 1.42"
9.8
0.39"
mm, inches
CB5-01
5 0.2"
1SBC101655S0201 - Rev. B
Main dimensions
Notes
N9
5
ABB | 5/341
Mechanical latching units
1SBC100040V0014
Description
WB75-A
E1
E2
E2676D
5
Terminal marking
For converting standard contactors into latched contactors.
The WB75-A block contains a mechanical latching device with electromagnetic impulse unlatching (AC or
DC) or manual unlatching.
Captive screw type connecting terminals, built-in cable clamps, M3.5 (+,-) pozidriv 2 screw with screwdriver guidance; delivered untightened and protected against accidental direct c ontact.
Operation
After closing, the contactor continues to be held in the closed position by the latching mechanism should
the supply voltage fail at the contactor coil terminals.
Contactor opening can be controlled:
– – electrically by an impulse (AC or DC) on the WB75-A block coil.
(the coil is not designed to be permanently energized)
–– manually by pressing the pushbutton on the front face of the WB75-A block.
Mounting
The WB75-A block is clipped onto the front face of the 1-stack contactor where it takes up two slots (see
dimension drawing). The two other slots do not accept CA4 single pole auxiliary contacts. Up to 2 CAL4-11
auxiliary contact blocks can be side-mounted on contactors (except NF22E and AF..-22-00, refer to main
accessory fitting details table in main accessories section).
Ordering details
For contactors
AF09 ... AF65
NF
Rated control circuit
voltage
Uc
V 50 Hz
or DC
V 60 Hz
24
24...28
42
42...48
48
48...55
110
110...127
220...230
220...255
230...240
230...277
380...415
380...440
415...440
440...480
Type
Order code
Pkg
qty
Weight
(1 pce)
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
FPTN372726R1001
FPTN372726R1002
FPTN372726R1003
FPTN372726R1004
FPTN372726R1006
FPTN372726R1005
FPTN372726R1007
FPTN372726R1008
1
1
1
1
1
1
1
1
kg
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
1SBC101634S0201 - Rev. B
Note: For WB75-A produced since week 06-2012.
WB75-A can not be used on AF80, AF96.
5/342 | ABB
Mechanical latching units
Technical data
Type
WB75-A
Utilization characteristics according to IEC
Rated insulation voltage Ui acc. to IEC 60947-1
Max. electrical impulse time
On AC coil (with load factor 5 %)
On DC coil (with load factor 3 %)
Min. electrical impulse time
For latching (energizing of the contactor coil)
For pull-out (energizing of the WB block coil)
Coil operating limits
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
DC control voltage
Rated control circuit voltage Uc
Coil consumption
690 V
20 s
8s
AC
DC
AC
DC
AC or DC supply
120 ms
120 ms
30 ms
50 ms
0.85…1.1 x Uc
Average pull-in value
Average holding value
24…480 V AC
90 VA
60 VA
Average pull-in value
Average holding value
24…440 V DC
110 W
110 W
5
Operating time
On contactor closing (latching)
Between coil energization and:
N.O. contact closing
N.C. contact opening
No difference with the operation of a contactor without mechanical latching unit
No difference with the operation of a contactor without mechanical latching unit
N.O. contact opening
N.C. contact closing
5…25 ms
7…28 ms
On contactor opening (unlatching)
Between WB coil energization and:
Mechanical durability
Number of operating cycles
Max. switching frequency
1 million operating cycles
3600 cycles/h with on-load factor of 8 %
Connecting characteristics
Flexible with ferrule
l L
Lugs
Tightening torque
Recommended
Max.
Screw terminals
All terminals
Screwdriver type
1x
2x
1x
2x
L<
l>
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.5 mm
1 Nm
1.2 Nm
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1SBC101676S0201 - Rev. A
Connection capacity (min. ... max.)
Rigid solid
ABB | 5/343
1SBC100020V0014
Other accessories
Ordering details
For contactors
Type
Order code
Pkg
qty
1SBC100021V0014
LDC4
BX4
Additional coil terminal blocks
Additional coil terminal blocks for a bottom access to the coil terminals of contactors or contactor relays.
AF09 ... AF96, NF
LDC4
1SBN070156T1000
10
0.010
Protective covers
1SBC100023V0014
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against
accidental contact.
AF09 ... AF96 1-stack contactors and NF contactor relays
4-pole CA4, 2-pole CAT4 auxiliary contact blocks and
TEF4 electronic timer
BX4-CA
BX4
BX4-CA
1SBN110108T1000
1SBN110109W1000
10
50
0.006
0.001
1SNC160101F0014
Note: BX4 produced since 13045 (day 045 - year 2013) are suitable for AF40 ... AF96.
BA4
1SBC100044V0014
BA5-50
Function markers AF09 ... AF370
Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500
marking table to identify your contactors, overload relays or manual motor starters.
Marker dimensions: 7 x 20 mm (.276" x .787").
AF09 ... AF370 contactors, TF thermal overload relays, EF electronic overload relays and MS116, MS132 manual motor starters
AMS 500 support plate for 8 BA4
HTP500 support plate
BA4
1SNA235156R2700
16
0.011
SPRC 1
HTP500-BA4
1SNA360010R1500
1SNA235712R2400
1
1
0.220
0.290
Function markers AF400 ... AF2650
Set of 50 function markers designed to be clipped onto the front face of devices. Details can be added to
these markers using a ball point pen, indelible felt-tip pen or pentel white.
Self-adhesive labels (not supplied) can also be added to them.
Marker dimensions: 7 x 19 mm (.276" x .748").
AF400 ... AF2650 and accessories
Main dimensions
BA5-50
1SBN110000R1000
1
0.017
mm, inches
44.8 1.76"
BX4
5/344 | ABB
1SBC101733S0201
6
0.24"
28 1.10"
5
Weight
(1 pce)
kg
1SBC100022V0014
Other accessories
Ordering details
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
10
10
10
0.003
0.004
0.005
BP38-4
Mounting pieces
1SBC100041V0014
Mounting piece for replacing installed contactors fixed by screws by AF contactors.
BDT4
For AF09 ... AF65, NF
From contactor
A26 ... A40, AL26 ... AL40
A40 ... A75, AE50 ... AE75, AF50 ... AF75
A95, A110, AE95, AE110, AF95, AF110
To contactor
AF09 ... AF38
AF40 ... AF65
AF80 ... AF96
BP38-4
BP65-4
BP96-4
1SBN112303T1000
1SBN113403T1000
1SBN113903T1000
Test block
5
BDT4 test block is suitable for switching on contactor off-load.
1SBC100042V0014
Marking on the block indicates the contactor type to fit with.
AF09 ... AF96, NF
BDT4
1SBN110122T1000
10
0.007
BDT4
For AF80 ... AF96
Main dimensions
mm, inches
78 3.07"
13 0.51"
60 2.36"
10 0.39"
4.6 0.18"
M6 1/4-20 UNC
5 0.20"
ø 6.2 0.24"
5 0.20"
5 0.20"
54 2.13"
BP38-4
M6 1/4-20 UNC
90 3.54"
70 2.76"
BP65-4
BP96-4
ABB | 5/345
1SBC101752S0201
4.6 0.18"
126 4.96"
136 5.35"
147.7 5.81"
90 3.54"
100 3.94"
119.5 4.70"
ø 6.2 0.24"
ø 4.2 0.17"
M4 8-32 UNC
5 0.20"
70 2.76"
80 3.15"
90 3.54"
45 1.77"
1SBC100038V0014
Additional terminal blocks
Description
The LD terminal block is designed to increase the connecting capacity of 3-pole AF26 ... AF38 contactors on
which it is fitted and for preparation of the wiring before final connection to the contactor.
LD38-4 blocks are 3-pole terminal blocks with tunnel terminals.
LD38-4
Ordering details
5
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
AF26 ... AF38
LD38-4
1SBN072308R1000
2
kg
0.070
Technical data
Types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Main terminals
LD38-4
690 V
600 V
Screw terminals with double connector
2 x (7 width x 5.8/9.2 depth)
Connection capacity (min. ... max.)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
1x 2.5...25 mm²
1x 2.5...25 mm² + 1x 2.5...16mm²
1x 2.5...16 mm²
1x 2.5...16mm² + 1x 2.5...10mm²
1x 2.5...16mm²
1x 2.5...16mm² + 1x 2.5...10mm²
1x AWG 8-4
2x AWG 8-6
14 mm
2.5 Nm / 22 lb.in
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20
Screw terminals
Delivered in closed position, screws of unused terminals must be tightened
Main terminals
M5
Screwdriver type Flat Ø 6.5 / Pozidriv 2
Note: The utilization of LD38-4 additional terminal blocks does not allow the use of BER and BEY connection sets.
Main dimensions
mm, inches
102 4.02"
5/346 | ABB
1SBC101734S0201
125 4.92"
30 1.18"
Terminal shrouds
Description
1SFC101038V0001
Main terminal protection for AF116 ... AF1250 contactors.
The auxiliary contact blocks and coils are designed to provide an IP 20 degree of protection.
The main terminals, equipped with compression lugs or cable clamps, can be protected against accidental direct
contact after wiring (EN 50274) by the addition of terminal shrouds (see table below).
Ordering details
LT140-30L
1SFC101041V0001
For contactors
1SFC101089V0001
LT370-30C
4-pole contactors
AF116 … AF140, with compression lugs
AF190 … AF205, with cable clamps
AF190 … AF205, with compression lugs
AF265 … AF370, with cable clamps
AF265 … AF370, with compression lugs
Order code
Pkg
qty
Weight
(1 pce)
kg
LT140-30L
LT205-30C
LT205-30L
LT205-30Y
1SFN124203R1000
1SFN124801R1000
1SFN124803R1000
1SFN124804R1000
2
2
2
1
0.070
0.050
0.220
0.050
LT370-30C
LT370-30L
LT370-30Y
1SFN125401R1000
1SFN125403R1000
1SFN125404R1000
2
2
1
0.035
0.280
0.075
LT370-30D
1SFN125406R1000
1
0.15
LT460-AC
LT460-AL
LT750-AC
LT750-AL
1SFN125701R1000
1SFN125703R1000
1SFN126101R1000
1SFN126103R1000
2
2
2
2
0.100
0.800
0.120
0.825
LT140-40L
LT205-40C
LT205-40L
LT370-40C
LT370-40L
1SFN124203R2000
1SFN124801R2000
1SFN124803R2000
1SFN125401R2000
1SFN125403R2000
2
2
2
2
2
0.090
0.060
0.290
0.040
0.370
5
1SFC101199V0001
LT460-AC
3-pole contactors
AF116 ... AF146, with compression lugs
AF190, AF205, with cable clamps
AF190, AF205, with compression lugs
AF190, AF205, with shorting bar or between contactor
and TOL/EOL in DOL starters
AF265 ... AF370, with cable clamps
AF265 ... AF370, with compression lugs
AF265 ... AF370, with shorting bar or between contactor
and TOL/EOL in DOL starters
AF265 ... AF370, for use with extending cable clamps,
ATK300/2 and OZXB4
AF400, AF460 with cable clamps
AF400, AF460 with compression lugs
AF580, AF750 with cable clamps
AF580, AF1250 with compression lugs
Type
1SFC101099C0201 - Rev. A
LT205-40
ABB | 5/347
Connections
1SFC101050V0001
Terminal enlargements
Description
Enlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger
connections to be mounted.
Ordering details
LW140
For contactors
3-pole contactors
AF116 ... AF146
AF190, AF205
AF265 ... AF370
AF400, AF460
AF580, AF750
AF1250
4-pole contactors
AF190 … AF205
AF265 … AF370
5
LW205-40
Dimensions
Type
Order code
Pkg
qty
Weight
(1 pce)
hole Ø
mm
bar
mm
6.5
10.5
10.5
10.5
13
13
13 x 3
17.5 x 5
20 x 5
25 x 5
40 x 6
50 x 10
LW140
LW205
LW370
LW460
LW750
LW1250
1SFN074207R1000
1SFN074807R1000
1SFN075407R1000
1SFN075707R1000
1SFN076107R1000
1SFN076407R1000
1
1
1
1
1
1
0.115
0.260
0.340
0.730
1.230
2.000
10.5
10.5
20 x 5
25 x 5
LW205-40
LW370-40
1SFN074807R2000
1SFN075407R2000
1
1
0.306
0.540
kg
Terminal extension
Description
Extension pieces designed to extend the main terminals of contactors for combined mounting of
contactors and connection sets.
1SFC101049V0001
Ordering details
For 3-pole contactors
Dimensions
AF116 ... AF146
AF190, AF205
AF265 ... AF370
AF400, AF460
AF580, AF750
hole Ø
mm
6.5
8.5
10.5
10.5
13
bar
mm
13 x3
17.5 x 5
20 x 5
25 x 5
40 x 6
Type
Order code
Pkg
qty
Weight
(1 pce)
LX140
LX205
LX370
LX460
LX750
1SFN074210R1000
1SFN074810R1000
1SFN075410R1000
1SFN075710R1000
1SFN076110R1000
1
1
1
1
1
kg
0.072
0.180
0.234
0.500
0.850
Connection sockets
LX140
Description
Connection socket can be used to replace built-in cable clamps in AF116 ... AF146.
Ordering details
1SFC101073V0001
For contactor
LL146-30
3-pole contactors
AF116 ... AF146
4-pole contactors
AF116 … AF140
AF190 … AF205
AF265 … AF370
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
LL146-30
1SFN074211R1000
6
0.102
LL146-40
LL205-40
LL370-40
1SFN074211R2000
1SFN074811R2000
1SFN075411R2000
8
2
2
0.132
0.216
0.224
Pkg
Weight
qty
(1 pce)
kg
Connection module
Description
Connection module can be fixed on AF116 ... AF146 delivered with bar terminals.
1SFC101046V0001
For contactor
LD146-30
5/348 | ABB
3-pole contactors
AF116 ... AF146
4-pole contactors
AF116 … AF140
Type
Order code
LD146-30
1SFN074208R1000
2
0.165
LD146-40
1SFN074208R2000
2
0.225
1SFC101100C0201 Rev. A
Ordering details
1SBC100024V0014
Terminal connecting strips and shorting bars
Description
1SFC101088V0001
LY16-4
LY185
Parallel and series connection of 3-pole contactors:
–– To obtain a star point (3 parallel-connected poles)
–– To connect poles in parallel and thus increase the AC load passing through the flow path made up of the
parallel-connected poles: LP, LY, LH, LF, LG.
The relevant cable cross-sectional area may limit the maximum permissible current. Consult information in
table below
–– To connect poles in series and thus increase the DC load controlled by the poles: LP, LY (only LY16-4 and
LY38-4 secable strips).
Types
LP
LY
for connection of "n" poles
n=2
n = 2 (secable LY16-4, LY38-4 connecting strips)
n=3
n=2
n=3
n=4
LH
LF
LG
with terminal
no
no
no
yes
yes
yes
insulated
no (1)
yes
yes (1)
no
yes
yes
5
1SBC100035V0014
(1) LP460 ... LP750, LY185 ... LY750 not insulated. Use terminal shrouds.
Ordering details
For contactors
LG16-4
Cable
Type
crosssectional
area
mm²
6
10
–
–
–
–
–
–
–
–
–
10
10
16
25
25
16
25
25
35
50
25
25
25
Order code
Pkg
qty
Weight
(1 pce)
LY16-4
1SBN071303T1000
10
kg
0.006
LY38-4
LY140
LY185
LY300
LY460
LY750
LP185
LP300
LP460
LP750
LH38-4
1SBN072303T1000
1SFN074203R1000
1SFN074703R1000
1SFN075103R1000
1SFN075703R1000
1SFN076103R1000
1SFN074712R1000
1SFN075112R1000
1SFN075712R1000
1SFN076112R1000
1SBN072304R1000
10
1
1
1
1
1
2
2
2
2
2
0.012
0.055
0.200
0.300
0.450
0.800
0.300
0.400
0.550
0.950
0.012
LF16-4
1SBN071305R1000
2
0.020
LF38-4
1SBN072305R1000
2
0.040
LG16-4
1SBN071306R1000
2
0.025
C
mm
22
16
23
31
23
inch
0.87"
0.63"
0.91"
1.22"
0.91"
Main dimensions
Type
LH38-4
C
LF16-4
LF38-4
LG16-4
For contactors
Dimensions
AF09
AF26
AF09
AF26
AF09
A
mm
111.20
114
121
135.20
124.20
...
...
...
...
...
AF16
AF38
AF16
AF38
AF16
inch
4.38"
4.49"
4.76"
5.32"
4.89"
B
mm
83
86
87
103
87
inch
3.27"
3.39"
3.43"
4.06"
3.43"
1SBC101735S0201
1SBC100036V0014
LF16-4
max. nominal continuous current
with "n" poles
in parallel
in series
2 poles 3 poles 4 poles 2 poles
A
AF09
30
33
–
25
AF12
32
36
–
27
AF16
34
40
–
30
AF26
50
60
–
45
AF116 … AF146 –
240
–
AF190, AF205
–
400
–
AF265 … AF370 –
670
–
AF400, AF460
–
1000
–
AF580, AF750
–
1650
–
AF190, AF205
300
–
–
AF265 … AF370 475
–
–
AF400, AF460
725
–
–
AF580, AF750
1200
–
–
AF09
45
–
–
AF12
50
–
–
AF16
54
–
–
AF26
81
–
–
AF30, AF38
90
–
–
AF09
62
–
AF12
70
–
AF16
75
–
AF26
112
–
AF30, AF38
125
–
AF09
–
–
70
–
AF12
–
–
78
–
AF16
–
–
84
–
A
1SBC100037V0014
LH38-4
B
ABB | 5/349
Connection accessories for starting solutions
1SBC100014V0014
Connecting links with manual motor starters
Description
The BEA insulated 3-pole connecting links are used to connect AF09 ... AF38 contactors with the MS116 or
MS132 manual motor starters.
The BEA insulated 3-pole connecting links ensure the electrical and mechanical connection between the
contactor and the associated manual motor starter.
BEA16-4
1SBC100016V0014
Ordering details
5
For 3-pole contactors
Manual motor starter
Type
Order code
Pkg
qty
AF09 ... AF16
MS116-0.16 … MS116-25,
MS132-0.16… MS132-25
MS116-0.16 … MS116-16,
MS132-0.16 ... MS132-10
MS116-20 … MS116-32,
MS132-12 ... MS132-32
BEA16-4
1SBN081306T1000
10
Weight
(1 pce)
kg
0.025
BEA26-4
1SBN082306T1000
10
0.025
BEA38-4
1SBN082306T2000
10
0.030
AF26 ... AF38
BER16-4
Connection sets for reversing contactors
Description
A1
A2
1
3
5
1
3
5
2
4
6
2
4
6
The BER and BEM connection sets are used to connect the main poles of two 3-pole contactors mounted
side by side.
The BER connection sets are made up of 1 upstream and 1 downstream connections.
The BEM connection sets are made up of 3 upstream and 3 downstream connections.
BER and BEM connection sets are insulated and made of solid copper bars.
A1
A2
Ordering details
1SFC101052V0001
BER, BEM
Reversing connections
BEP140-30
For 3-pole contactors
Type
Order code
Pkg
qty
AF09 ... AF16
AF26 ... AF38
AF40 ... AF65
AF80, AF96
AF116 ... AF146
AF190, AF205
AF265 ... AF370
AF400, AF460
AF580, AF750
BER16-4
BER38-4
BER65-4
BER96-4
BER140-4
BER205-4
BER370-4
BEM460-30
BEM750-30
1SBN081311R1000
1SBN082311R1000
1SBN083411R1000
1SBN083911R1000
1SFN084211R1000
1SFN084811R1000
1SFN085411R1000
1SFN085701R1000
1SFN086101R1000
1
1
1
1
1
1
1
1
1
Weight
(1 pce)
kg
0.045
0.100
0.175
0.250
0.615
1.237
2.140
4.400
7.300
Phase to phase connections
Description
A1
A2
1
3
5
1
3
5
2
4
6
2
4
6
The BEP and BES connection sets are used to connect phase to phase the main poles of two contactors
mounted side by side. 4-pole contactors will then operate as source reversing contactors.
The BEP connection sets are made up of 1 upstream or downstream connections.
The BES connection sets are made up of 3 upstream or downstream connections.
BEP and BES connection sets are insulated and made of solid copper bars.
A1
A2
A1
3
5
7
1
3
5
7
2
4
6
8
2
4
6
8
A1
A2
E0743D
A2
1
BEP
4-pole changeover
connections
5/350 | ABB
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
3-pole contactors
AF116 … AF146
AF190, AF205
AF265 … AF370
AF400, AF460
AF580, AF750
BEP140-30
BEP205-30
BEP370-30
BES460
BES750
1SFN084214R1000
1SFN084814R1000
1SFN085414R1000
1SFN085704R1000
1SFN086104R1000
1
1
1
1
1
0.320
0.534
0.926
2.200
3.700
4-pole contactors
AF116 ... AF140
AF190 ... AF205
AF265 ... AF370
BEP140-40
BEP205-40
BEP370-40
1SFN084214R2000
1SFN084814R2000
1SFN085414R2000
1
1
1
0.420
0.710
1.230
1SBC101736S0201 Rev. A
Ordering details
BEP, BES
3-pole phase to phase
connections
Connection sets for star-delta starter
1SBC100018V0014
Description
BEY16-4
The BEY and BED connection sets are used to connect the main poles of the Line, Delta and Star contactors
of a star-delta starter.
The connection sets are made up of:
–– Line contactor / delta contactor:
-- BEY: upstream phase-to-phase connection
-- BED: upstream connection in parallel
–– Delta contactor / star contactor: downstream connection in parallel
–– Star contactor: star point upstream
–– Insulated, solid copper bar.
Ordering details
A2
1
3
5
2
4
6
A1
A2
1
3
5
2
4
6
A1
A2
1
3
5
2
4
6
AF09 ... AF370
Line-delta-star connection
A1
A2
1
3
5
2
4
6
A1
A2
1
3
5
2
4
6
A1
A2
1
3
5
2
4
6
AF400 ... AF750
Star-delta-line connection
Interlock unit between delta &
star contactors
Type
Order code
Pkg
qty
AF09 ... AF16
AF26 ... AF38
AF40 ... AF65
AF80, AF96
AF116 ... AF146
AF190 ... AF205 (line and delta)
AF140 ... AF146 (star)
AF190, AF205
AF265 ... AF370 (line and delta)
AF190 ... AF205 (star)
AF265 ... AF370
AF400 ... AF460
AF580 ... AF750 (line and delta)
AF400 ... AF460 (star)
AF580 ... AF750
With or without VM4 or VEM4
With or without VM4 or VEM4
With or without VM96-4
With or without VM96-4
With or without VM19
With or without VM140/190
BEY16-4
BEY38-4
BEY65-4
BEY96-4
BEY140-4
BEY190-4
1SBN081313R2000
1SBN082713R2000
1SBN083413R2000
1SBN083913R2000
1SFN084413R1000
1SFN084813R1000
1
1
1
1
1
1
Weight
(1 pce)
kg
0.050
0.110
0.200
0.250
1.040
1.154
With or without VM19
With or without VM205/265
BEY205-4
BEY265-4
1SFN085213R1000
1SFN085413R1000
1
1
1.205
2.020
With or without VM19
With or without VM750H
With or without VM750H
BEY370-4
BED460
BED580
1SFN085813R1000
1SFN085703R1000
1SFN085903R1000
1
1
1
2.110
4.700
6.300
With or without VM750H
BED750
1SFN086103R1000
1
7.700
5
1SBC101737S0201
A1
For 3-pole line, delta & star
contactors
ABB | 5/351
Connection bars
1SFC101061V0001
Connection bars between contactors and MCCB
Description
Connection between contactors/starters and moulded case circuit breakers.
These connection sets are solid copper bars.
Ordering details
BEA140/XT2
1SFC101064V0001
For 3-pole contactors
BEA205/T4
1SFC101065V0001
5
BEA370/T5
MCCB
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Vertical assembly
AF116 ... AF146
AF116 ... AF146
AF190, AF205
AF190, AF205
AF265 ... AF370
AF400 ... AF750
AF400 ... AF750
XT2
XT4
XT4
T4
T5
BEA140/XT2
BEA140/XT4
BEA205/XT4
BEA205/T4
BEA370/T5
1SFN084206R1000
1SFN084206R1001
1SFN084806R1000
1SFN084806R1001
1SFN085406R1000
1
1
1
1
1
T6
T5
BEA750/T6
BEA750/T5
1SFN086106R1000
1SFN086106R1001
1
1
0.058
0.068
0.200
0.190
0.350
0.410
0.410
Vertical assembly with control wire terminals (also suitable when using busbar kits for starter combinations)
AF400 ... AF750
T5
BEA750D/T5
1SFN086106R1003
1
0.720
AF400 ... AF750
T6
BEA750D/T6
1SFN086106R1002
1
0.720
Horizontal assembly (also suitable when using busbar kits for starter combinations)
AF400, AF460
T4
BEA460H/T4
1SFN085907R1000
1
2.450
Pkg
qty
Weight
(1 pce)
Connection bars between contactors and switch fuse
Description
Connection between contactors/starters and moulded case circuit breakers.
These connection sets are solid copper bars.
Ordering details
For 3-pole contactors
Switch fuse
Type
Order code
kg
Vertical assembly
AF400, AF460
AF460 ... AF750
OESA400
OESA630 to OESA800
Horizontal assembly
AF400, AF460
OESA400...LR
BEF460/OESA400
BEF750/OESA800
1SFN085708R1000
1SFN086108R1000
1
1
0.340
0.740
OESA460H/OESA400
1SFN085709R1000
1
1.250
1SFC101103C0201 Rev. A
Note: The BEF connection bars provided for the A145 ... A300 contactors can be used for the AF145 ... AF300 contactors.
5/352 | ABB
Mounting plates
Description
1SFC101087V0001
Mounting plates with fixing holes for the specified 3-pole contactors and overload relays.
Ordering details
For 3-pole contactors
For
overload relays
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
PN460
Mounting plates for Direct on line starters
E500DU
AF400, AF460
E800DU
AF580, AF750
For two contactors side
by side with space for
mechanical interlock
For one or two
overload relays
PN460-11
PN750-11
1SFN095705R1000
1SFN096105R1000
1
1
2.120
2.500
Type
Order code
Pkg
qty
Weight
(1 pce)
5
kg
Mounting plates for mechanical interlocked contactors, reversing starters and two speed starters for
double windings
E500DU
PN460-21
1SFN095701R1000
1
3.490
AF400, AF460
E800DU
PN750-21
1SFN096101R1000
1
4.230
AF580, AF750
For main
and delta contactors
For star
contactor (1)
For
overload relays
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Mounting plates for star-delta starters and two speed starters for single windings
AF400, AF460
A300, AF400
E500DU
PN460-41
1SFN095703R1000
AF580, AF750
AF400 ... AF580 E800DU
PN750-41
1SFN096103R1000
1
1
5.310
6.320
1SFC101106C0201
(1) Space for mechanical interlock included.
ABB | 5/353
Adapter plates
Description
1SFC101048V0001
Adapter plates with fixing holes for replacing installed contactors.
Ordering details
From contactors
To contactor
Type
Order code
Pkg
qty
Weight
(1 pce)
A95, AF95, A110, AF110
EH150, EH160, EH175, EH210, EG160
EH250, EH260, EH300
EH370, EH550, EG315
EH700, EH800
OKYM150, OKYM175
OKYM200, OKYM250
OKYM315
OKYM400
OKYM500
EH550, EG630, OKYM630
AF116, AF140, AF146
AF190, AF205
AF265, AF305, AF370
AF400, AF460, AF580
AF750
AF190
AF265, AF305, AF370
AF400, AF460
AF400, AF460
AF580
AF580, AF750
PR146-1
PR210-1
PR300-1
PR460-1
PR750-1
PR185-2
PR300-2
PR400-2
PR460-2
PR580-2
PR750-2
1SFN094200R1000
1SFN094900R1000
1SFN095300R1000
1SFN095700R1000
1SFN096100R1000
1SFN095100R1001
1SFN095300R1001
1SFN095700R1002
1SFN095700R1001
1SFN096100R1002
1SFN096100R1001
1
1
1
1
1
1
1
1
1
1
1
kg
0.300
0.440
0.560
0.900
0.500
0.500
0.500
0.820
0.800
0.700
1.100
PR146-1
5
l
Dimensions (mm)
h
E2119D
L
Type of the plate
Dimensions
PR146-1
PR210-1
PR300-1
PR460-1
PR750-1
PR185-2
PR300-2
PR400-2
PR460-2
PR580-2
PR750-2
L
150
200
200
278
283
202
202
278
278
283
283
Fixing holes
I
90
132
172
198
244
152
152
151
176
176
255
h
15
11.5
11.5
11.5
11.5
11.2
11.2
11.5
11.5
11.5
11.5
mm
4 x ø 6.5
4xø7
4xø7
4xø7
4xø7
4 x ø 11
4 x ø 11
4 x ø 11
4 x ø 11
4 x ø 11
4 x ø 14
1SFC101107C0201
Fixing holes according to the plate types
5/354 | ABB
Contactor coils, main contact sets and arc chutes
Contactor coils
1SFC101007F0201
Ordering details
For contactors
ZAF1650
AF1350 ... AF2050
Rated control circuit
voltage
Uc min. ... Uc max.
V 50/60 Hz V DC
24…60
48…130
48…130
100…250
100…250
250…500
250…500
24…60
48…130
48…130
100…250
100…250
250…500
250…500
100…250
100…250
AF2650
100...250
AF400, AF460
AF580 ... AF1250
100...250
Type
Order code
Pkg
qty
Weight
(1 pce)
ZAF460
ZAF460
ZAF460
ZAF460
ZAF750
ZAF750
ZAF750
ZAF750
ZAF1650 (1)
ZP1650 (2)
ZAF2650 (1)
ZP2650 (2)
1SFN155770R6806
1SFN155770R6906
1SFN155770R7006
1SFN155770R7106
1SFN156170R6806
1SFN156170R6906
1SFN156170R7006
1SFN156170R7106
1SFN156570R7026
1SFN166521R1070
1SFN156670R7026
1SFN166621R1070
1
1
1
1
1
1
1
1
1 set
1
1 set
1
kg
0.525
0.525
0.525
0.525
1.335
1.335
1.335
1.335
0.900
0.300
0.900
0.300
5
(1) One set of two coil.
(2) Printed circuit board.
Main contact sets
The contact sets for 3-pole contactors consists of six fixed contacts, three moving contacts, springs and
the required screws.
Ordering details
For 3-pole contactors
Type
Order code
Pkg
qty
AF400
AF460
AF580
AF750
AF1250
AF1350
AF1650
AF2050
AF2650
ZL400
ZL460
ZL580
ZL750
ZL1250
ZL1350
ZL1650
ZL2050
ZL2650
1SFN165703R1000
1SFN165903R1000
1SFN166103R1000
1SFN166303R1000
1SFN166403R1000
1SFN166503R1000
1SFN166703R1000
1SFN167003R1000
1SFN166603R1000
1
1
1
1
1
1
1
1
1
For contactors
Type
Order code
Pkg
qty
AF400, AF460
AF580, AF750, AF1250
AF1350, AF1650, AF2050
AF2650
ZW460
ZW750
ZW1650
ZW2650
1SFN165710R1000
1SFN166110R1000
1SFN166510R1000
1SFN166610R1000
1
1
1
1
ZL1650
Weight
(1 pce)
kg
1.320
1.320
1.840
1.840
1.840
2.500
3.500
3.500
1.200
Arc chutes
Ordering details
Weight
(1 pce)
kg
1.380
1.500
4.000
4.000
1SFC101137C0201 Rev. A
1SFC101009F0201
Description
ABB | 5/355
Summary_5-10
5
5/356 | ABB
Accessories for UA, UA..RA contactors and
GA75, GAE75, GAF contactors
Auxiliary contact blocks
5/358
Electronic timers
5/365
Mechanical and electrical interlock units
5/368
CA5, CE5, CAL5 and TEF5 fitting details
5/370
Function markers - Mounting piece
5/371
Surge suppressors for contactor coils
5/372
Interface relays
5/374
Mechanical latching units
5/376
Additional terminal blocks and others accessories
5/378
Terminals for control lead connections
5/379
Contactor coils and main contact sets
5/380
Summary_5-10
5
ABB | 5/357
Auxiliary contact blocks
1SBC580992F0301
Description
1SBC573794F0302
CA5-10
5
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard
industrial environments.
Types of auxiliary contact blocks for front mounting:
–– CA5
1 or 4-pole block, instantaneous with N.O., N.C. contacts
–– CC5
1-pole block, with N.O. leading contact or N.C. lagging contact.
Select the 4-pole auxiliary contact blocks CA5 type, according to the contactor type for compliance with
the standard requirements (see "Terminal Marking and Positioning").
Types of auxiliary contact blocks for side mounting:
–– CAL
2-pole block instantaneous N.O. + N.C. contacts.
For clipping onto the right- and/or left-hand side of the contactors.
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact and bear the corresponding function marking.
Ordering details (1)
CA5-40E
For contactors
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
1SBC573752F0301
kg
1SFC101033F0201
CAL5-11
1SBN010010R1010
1SBN010010R1001
1SBN010011R1010
1SBN010011R1001
10
10
10
10
0.014
0.014
0.014
0.014
Front-mounted instantaneous auxiliary contact blocks, 4-pole
UA16 ... UA30
2 2
– – CA5-22M
3 1
– – CA5-31M
1 3
– – CA5-13M
0 4
– – CA5-04M
1 1
1 1 CA5-11/11M
UA50 ... UA110
2 2
– – CA5-22E
3 1
– – CA5-31E
4 0
– – CA5-40E
0 4
– – CA5-04E
1 1
1 1 CA5-11/11E
1SBN010040R1122
1SBN010040R1131
1SBN010040R1113
1SBN010040R1104
1SBN010040R1118
1SBN010040R1022
1SBN010040R1031
1SBN010040R1040
1SBN010040R1004
1SBN010040R1018
2
2
2
2
2
2
2
2
2
2
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
Side-mounted instantaneous auxiliary contact blocks, 2-pole
1 1
– – CAL5-11
UA16 ... UA75
UA95, UA110
1 1
– – CAL18-11
1SBN010020R1011
1SFN010720R1011
2
2
0.050
0.050
(1) For each contactor type, refer to "Accessory fitting details" table.
Note:
–– The front-mounted auxiliary contact blocks provided for the UA75 contactors can be used with the GA and GAE types
–– The CAL auxiliary contact blocks can be used with GA contactors:
GA75-10-00: 2 x CAL5-11 blocks
GA75-10-11: 1 x CAL5-11 block
GAE75-10-00: 1 x CAL5-11 block
GAE75-10-11: no add-on block.
–– The CAL auxiliary contact blocks can be used with UA..RA contactors. See "Accessory fitting details" for this contactor type.
1SBC101520S0201 - Rev. B
CAL18-11
Front-mounted instantaneous auxiliary contact blocks, 1-pole
UA16 ... UA110
1 0
– – CA5-10
0 1
– – CA5-01
– –
1 0 CC5-10
– –
0 1 CC5-01
5/358 | ABB
Auxiliary contact blocks
Technical data
Types
Front mounted
Side mounted
1-pole CA5, 1-pole CC5, 4-pole CA5
CAL5-11
CAL18-11, CAL18-11B
Contact utilization characteristics according to IEC
IEC 60947-5-1 and EN 60947-5-1
690 V
24...690 V AC
16 A
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
24-127 V 50/60 Hz
220-240 V 50/60 Hz
380-440 V 50/60 Hz
500-690 V 50/60 Hz
acc. to IEC 60947-5-1
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
5
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.3 A / 66 W
0.3 A / 75 W
10 A
for 1.0 s 100 A
for 0.1 s 140 A
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
A40 … A75 contactors
with failure rate acc. to IEC 60947-5-4
A95 … A110 contactors
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Electrical durability
6A
4A
3A
2A
10 x Ie AC-15
10 x Ie AC-15
Max. switching frequency
Number of operating cycles
Max. switching frequency
17 V / 1 mA
≤ 10-7
24 V / 50 mA
–
0.1 W
10 millions (UA16 … UA75)
3 millions (UA95 … UA110)
–
–
10 millions
–
–
24 V / 50 mA (0.5 million of operating cycles)
≤ 10-6
0.15 W
5 millions (UA95 ... UA110)
3 millions (GAF185 ... GAF750)
0.5 million (GAF1250 ... GAF2050)
3600 cycles/h
see "Electrical durability" curves
AC-15 1200 cycles/h
DC-13 900 cycles/h
Contact utilization characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
600 V AC, 250 V DC
A600, Q300
10 A
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with ferrule
l L
Lugs
Tightening torque
Degree of protection
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
7.7 mm
3.7 mm
1 Nm
Terminals IP20
1x
2x
1x
2x
L≤
l>
8 mm
3.7 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1SBC101522S0201 - Rev. B
Screw terminals
All terminals
Screwdriver type
ABB | 5/359
Auxiliary contact blocks
for severe industrial environments
Description
1SBC581011F0301
The auxiliary contact blocks are used for the operation of auxiliary and control circuits for severe industrial
environments.
CE5-01W
Types of auxiliary contact blocks for front mounting:
–– CE5
1-pole block, instantaneous with N.O. contact or N.C. contact, designed in 2 protection versions:
-- CE5-.. D with built-in microswitch IP40, degree of protection (IP20 on terminals)
-- CE5-.. W with built-in microswitch IP67, degree of protection (IP20 on terminals).
Types of auxiliary contact blocks for side mounting:
–– CEL18 1-pole block with built-in microswitch IP67 degree of protection (IP20 on terminals).
Instantaneous N.O. or N.C. contact.
For clipping onto the right- and/or left-hand side of the contactors.
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact and bear the corresponding function marking.
5
Ordering details (1)
For contactors
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
Front-mounting instantaneous auxiliary contact blocks, 1-pole
UA16 ... UA75
1 –
– – CE5-10D0.1
– 1
– – CE5-01D0.1
1 –
– – CE5-10D2
– 1
– – CE5-01D2
1 –
– – CE5-10W0.1
– 1
– – CE5-01W0.1
1 –
– – CE5-10W2
– 1
– – CE5-01W2
1SBN010015R1010
1SBN010015R1001
1SBN010017R1010
1SBN010017R1001
1SBN010016R1010
1SBN010016R1001
1SBN010018R1010
1SBN010018R1001
1
1
1
1
1
1
1
1
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
Side-mounting instantaneous auxiliary contact blocks, 1-pole microswitch auxiliary contact N.O. or N.C.
UA95, UA110
1 0
– – CEL18-10
1SFN010716R1010
1
0.050
UA95, UA110
0
1
–
–
CEL18-01
1SFN010716R1001
1
0.050
1SBC101577S0201 - Rev. B
(1) For each contactor type, refer to "Accessory fitting details" table.
Note: The front-mounted auxiliary contact blocks provided for the UA contactors can be used with the GA and GAE types.
The side-mounted auxiliary contact blocks provided for the UA95, UA110 contactors can be used with the GAF types.
5/360 | ABB
Auxiliary contact blocks
Technical data
Front-mounted
1-pole CE5-..0.1
Types
Side-mounted
1-pole CE5-..2
CEL18-10, CEL18-01
Contact utilization characteristics according to IEC
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current
24-127 V 50/60 Hz
220-240 V 50/60 Hz
acc. to IEC 60947-5-1
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
acc. to IEC 60947-5-1
Short-circuit protection device
Minimum switching capacity
A40 … A75 contactors
With failure rate acc. to IEC 60947-5-4
A95 … A110 contactors
With failure rate acc. to IEC 60947-5-4
Mechanical durability
Number of operating cycles
Electrical durability
Max. switching frequency
Number of operating cycles
Max. switching frequency
IEC 60947-5-1 and EN 60947-5-1
250 V
125 V
250 V
0.1 A
2A
AC-14
AC-15
0.1 A
2A
–
2A
6 x Ie AC-14
10 x Ie AC-15
6 x Ie AC-14
10 x Ie AC-15
DC-12
0.1 A
2A
0.1 A
1A
0.1 A
0.3 A
0.1 A
0.2 A
–
0.2 A
–
0.1 A
0.1 A (FF type fuses) (1)
10 A (FF type fuses) (1)
3 V / 1 mA
–
3 V / 1 mA
–
5 millions for CE5-..D0.1
2.5 millions for CE5-..W0.1
3600 cycles/h
2.5 millions for CE5-..D0.1
0.7 millions for CE5-..W0.1
AC-14, 1200 cycles/h
AC-15
DC-12
17 V / 1 mA
≤ 10-7
17 V / 1 mA
≤ 10-7
5 millions for CE5-..D2
2.5 millions for CE5-..W2
1 million for CE5-..D2
0.3 millions for CE5-..W2
125 V
0.1 A
AC-14
0.1 A
–
6 x Ie AC-14
6 x Ie AC-14
0.1
0.1
0.1
0.1
–
–
0.1
A
A
A
A
5
A (FF type fuses) (1)
3 V / 1 mA
–
–
–
1 million
–
1200 cycles/h
0.7 millions
900 cycles/h
Contact utilization characteristics according to UL / CSA
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
UL 508, CSA C22.2 N°14
125 V AC / 110 V DC
250 V AC / 220 V DC
125 V
0.1 A
2 A
0.1 A
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with ferrule
l L
Bars or lugs
Connection capacity acc. to UL/CSA
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
7.7 mm
3.7 mm
1 or 2 x AWG 18...14
1 Nm
Terminals IP20
Microswitches IP40 for CE5-..D0.1
IP40 for CE5-..D2
IP67
IP67 for CE5-..W0.1
IP67 for CE5-..W2
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1x
2x
1x
2x
L≤
l>
1SBC101584S0201
(1) or HRC fuses for very fast action (6.3 x 32 mm size).
ABB | 5/361
Auxiliary contacts
Electrical durability
Electrical durability for AC-15 utilization category
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
These curves represent the electrical durability of the built-in or add-on auxiliary contacts, in relation to the breaking current.
The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.
30
20
–– 1-pole and 4-pole CA5,
1-pole CC5,
2-pole CAL5 and CAL18 add-on auxiliary contacts.
10
3
Example:
Breaking current = 1.2 A
On the opposite curve at intersection "O" 1.2 A the
corresponding value for the electrical durability is approximately 2.7.106 operating cycles.
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2 3 4 5 6
1.2
Breaking current (A)
10
Electrical durability for DC-13 utilization category
DC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1: making and breaking current = Ie with Ue value.
100
70
50
6
1.10 cycles
–– 1-pole and 4-pole CA5,
1-pole CC5,
2-pole CAL5 and CAL18 add-on auxiliary contacts.
6
Breaking power (W)
3.10 cycles
20
6
10.10 cycles
10
5
2
1
10
20 24
50
72
100
200 250
Example:
Control of DC electro-magnet: Ue voltage = 72 V DC and
breaking power = 70 W.
On the opposite curve at intersection "O" 72 V / 70 W the
corresponding value for the electrical durability is approximately 2.106 operating cycles.
500
Voltage (V)
1SBC101588S0201 - Rev. A
5
Million operating cycles
5
2.7
5/362 | ABB
Add-on auxiliary contacts
Terminal marking and positioning
1-pole auxiliary contacts
-3
-1
-1
NC
NO
NC
-2
-3
NO
-4
-4
-2
CE5-01, CEL18-01
CA5-10
CA5-01
-5
CE5-10, CEL18-10
-7
NO
NC
-8
-6
CC5-10
CC5-01
5
2-pole auxiliary contacts
32X /
NO
44X /
21X
31X
22X /
43X /
NC
13X
32X
44X
43X
14X /
31X /
NC
22X
21X /
NO
14X
13X /
CAL5-11, CAL18-11
(Left-side mounted)
CAL5-11, CAL18-11
(Right-side mounted)
17X /
35X /
36X /
48X /
25X
35X
26X /
48X
47X
CCL5-11
(Left-side mounted)
NO
NC
17X
36X
18X /
47X /
26X
NC
18X
25X /
NO
CCL5-11
(Right-side mounted)
4-pole auxiliary contacts
11
21
31
41
21
31
41
51
NC
NC
NC
NC
NC
NC
NC
NC
12
22
32
42
22
32
42
52
CA5-04M
CA5-04E
14
21
31
NC
NC
22
32
43
NO
44
CA5-22E
13
NO
14
21
NC
22
13
14
23
NO
24
33
NO
34
43
NO
44
13
14
NC
22
32
43
NO
53
NO
54
44
21
NC
22
33
NO
34
43
53
NO
NO
44
54
CA5-31M
33
NO
34
43
NO
44
CA5-40E
NO
31
NC
CA5-22M
CA5-31E
NO
21
21
31
41
NC
NC
NC
22
32
42
53
NO
54
1SBC101586S0201 - Rev. A
13
NO
CA5-13M
21
35
NC
NC
22
36
CA5-11/11E
47
NO
48
21
NC
22
33
NO
34
45
NC
57
NO
46
58
CA5-11/11M
ABB | 5/363
Notes
N11
5
5/364 | ABB
Electronic timers
TEF5-OFF
TEF5 frontal electronic timers are used for realizing timing function and are available in ON-delay and OFFdelay versions.
Compact solution in cabinet compared to separate timers
TEF5 electronic timers are front-mounted and locked on contactors.
A mechanical indicator allows to show the state of the contactor.
TEF5 electronic timers are supplied by direct wiring to the coil terminals A1 - A2 of the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against surges in the contactor coil.
Available for a wide control voltage range 24...240 V AC/DC
TEF5-ON or TEF5-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently
of the control system. The time delay ranges are selected by a switch and the time delay can be adjusted
by means of a rotary switch. The timing function is activated by closing or opening the device on which the
timer is mounted. The OFF-delay version operates without additional control supply.
5
Ordering details
For contactors,
contactor relays
Time delay
range
Delay
type
selected by
switch
Rated control
circuit voltage
Uc
Auxiliary Type
contacts
Order code
Pkg
(1 pce)
24...240
1
1
TEF5-ON
1SBN020312R1000
kg
0.065
OFF-delay 24...240
1
1
TEF5-OFF
1SBN020314R1000
0.065
V 50/60 Hz or DC
UA16 ... UA75
GA75, GAE75
0.1...1 s
1...10 s
10...100 s
Weight
ON-delay
1SBC101675S0201 - Rev. B
1SBC101396F0014
Description
ABB | 5/365
Electronic timers
Technical data
Contact utilization characteristics according to IEC
Types
Standards
Rated insulation voltage Ui
acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
24-127 V 50/60 Hz
acc. to IEC 60947-5-1
220-240 V 50/60 Hz
TEF5-OFF
400 V
4 kV
240 V
50 / 60 Hz
5 A
3 A
1.5 A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
1 A / 24 W
6 A
for 1.0 s 8 A
for 0.1 s 8 A
12 V / 3 mA
24 V DC 10-7
0.1 W
ON-delay
24 V DC
OFF-delay
150 ms
min.
Uc (A1 - A2)
1s
min.
Uc (A1 - A2)
100 ms
min.
N.O. (67 - 68)
100 ms
min.
N.O. (67 - 68)
N.C. (55 - 56)
N.C. (55 - 56)
t
t
Bistable relay inside.
Before use, once apply Uc then switch it off in order to initialize position of the contacts.
Control circuit voltage
AC control voltage
50/60 Hz
DC control voltage
Rated control circuit voltage Uc
Average consumption
Rated control circuit voltage Uc
Average consumption
Rated frequency limits
Supply voltage range
Overvoltage protection
Time delay range (t) selected by switch
24...240 V AC
1.5 mA RMS
24...240 V DC
1.5 mA
50 / 60 Hz
0.85...1.1 x Uc (at θ ≤ 70 °C)
Varistor included
1 mA RMS
1 mA
0.1...1 s
1...10 s
10...100 s
On-load reiteration accuracy under constant conditions
Minimum ON period
Recovery time
Ambient air temperature Operation
Storage
Climatic withstand
Maximum operating altitude
Mounting positions
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
(Mounting position 1)
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
AC-15
DC-13
≤1%
0.1 s
1 s
0.15 s
0.1 s
-25 °C ... +70 °C
-40 °C ... +80 °C
Category B according to IEC 60947-1 Annex Q
2000 m
Acc. to mounting positions permitted on contactors or contactor relays
1/2 sinusoidal shock for 11 ms: no change in contact position
Same as contactor or contactor relay
5 millions operating cycles
3600 cycles/h
1800 cycles/h
1200 cycles/h
900 cycles/h
1SBC101674S0201
5
Making capacity
Breaking capacity
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 3 A
Function diagram
TEF5-ON
IEC 60947-5-1 and EN 60947-5-1
5/366 | ABB
Electronic timers
Technical data
Contact utilization characteristics according to UL / CSA
Types
Standards
Rated insulation voltage Ui
acc. to UL / CSA
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
TEF5-ON
UL 508, CSA C22.2 N°14
TEF5-OFF
300 V
240 V
B300, R300
5A
3600 VA
360 VA
1A
28 VA
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
l L
Lugs
1x
2x
1x
2x
1x
2x
L≤
l>
1 or 2 x
5
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
8 mm
3.7 mm
AWG 18...14
10 mm
1 N.m / 9 lb.in
Connection capacity acc. to UL / CSA
Stripping length
Tightening torque
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20
Screw terminals
Delivered in open position, screws of unused terminals should be tightened
All terminals
M3.5
Screwdriver type
Flat Ø 5.5 / Pozidriv 2
Terminal Marking
55 NC
67 NO
55 NC
67 NO
A1
A1
A2
KM1
56 NC
68 NO
A2
56 NC
68 NO
1SBC101674S0201
KM1
ABB | 5/367
Mechanical and electrical interlock units
1SBC101429F0014
Description
When mounted between two contactors, the mechanical interlock unit prevents one of the contactors
from closing as long as the other contactor is closed.
VE interlock units are used for mechanical and electrical interlocking of two AC or DC operated contactors mounted side by side.
Ordering details
VE5-2
For contactors
Mounting
Type
Order code
Mechanical and electrical interlock units for two horizontal mounted contactors
GA75, GAE75
Rail mounting
VE5-2
1SBN030210R1000
Pkg
qty
Weight
(1 pce)
kg
1
0.146
1SBC101525S0201 - Rev. B
5
5/368 | ABB
Mechanical and electrical interlock units
Technical data
Types
VE5-2
Contact utilization characteristics according to IEC
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device - gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
IEC 60947-5-1 and EN 60947-5-1
690 V
24...690 V
16 A
24-127 V 50/60 Hz
220-240 V 50/60 Hz
380-440 V 50/60 Hz
500-690 V 50/60 Hz
6A
4A
3A
2A
10 x Ie AC-15
10 x Ie AC-15
5
6A
2.8 A
1A
0.55 A
0.3 A
10 A
for 1.0 s 100 A
for 0.1 s 140 A
0.15 W
24 V DC
48 V DC
72 V DC
125 V DC
250 V DC
5 millions operating cycles
600 cycles/h
Utilization characteristics according to UL/CSA
UL 508, CSA C22.2 N°14
600 V
Standards
Max. operational voltage
Connecting characteristics
Flexible with ferrule
l L
Lugs
Tightening torque
Recommended
Max.
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
Terminal marking
1x
2x
1x
2x
L<
l>
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.5 mm
1 Nm
1.2 Nm
IP20
delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
01
01
NC
NC
02
02
E0085D1
Connection capacity (min. ... max.)
Rigid solid
1SBC101331S0201 - Rev. B
Technical note: when, during switching, the arc time is estimated to more than 40 ms, the closing signal of one of the two contactors must be delayed with respect to the opening
signal of the other contactor in order to prevent a short-circuit.
Use a TEF5 electronic timer according to application use with time lapse for GA75, GAE75 contators.
ABB | 5/369
CA5, CE5, CAL, CEL18 and TEF5 fitting details
Many configurations are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Auxiliary contact blocks
Electronic timer
1-pole CA5
2-pole CAL
1-pole CE5
UA contactors
UA16 ... UA26
UA30
UA50 ... UA75
3 0
3 0
3 0
3 0
UA95, UA110
3 0
3 0
1 0
0 0
1 1
0 0
1 1
UA..RA contactors
UA16-30-10RA
3 0
UA26-30-10RA
3 0
UA30-30-10RA
3 0
1 0
1 0
1 0
UA50-30-00RA
UA63-30-00RA
UA75-30-00RA
UA95-30-00RA
UA110-30-00RA
0
0
0
0
0
3
3
3
3
3
0
0
0
0
0
GA75, GAE75 contactors
GA75
1 0
1 0
GAE75
1 0
1 0
0
0
0
0
0
0 0
1 1
0 0
1 1
1
1
1
1
1
1
1
1
1
1
1
1
to
to
to
to
to
to
to
to
to
to
to
to
4
2
5
3
6
5
6
5
6
5
6
5
x
x
x
x
x
x
x
x
x
x
x
x
CA5
CE5 max.
CA5
CE5 max.
CA5
CE5 max.
CA5
CE5 max.
CA5
CE5 max.
CA5
CE5 max.
(1)
(1)
(2)
(2)
(2)
(2)
–
4-pole CA5
TEF5
1-pole CEL18
or 1 x 4-pole CA5
or 1 x TEF5
+ 1 to 2 x CAL5-11
–
+ 1 to 2 x CAL5-11
–
+ 1 to 2 x CAL5-11
–
+ 1 x CAL5-11
–
+ 1 to 2 x CAL18-11
or 1 to 2 x CEL18
+ 1 x CAL18-11
or 1 x CEL18
–
+ 1 x 1-pole CA5 or CE5 (1)
or 1 x 4-pole CA5
+ 1 x 1-pole CA5 or CE5 (1)
or 1 x 4-pole CA5
+ 2 x 1-pole CA5 or CE5 (1)
or 1 x 4-pole CA5
+ 2 x 1-pole CA5 or CE5 (1)
or 1 x 4-pole CA5
+ 1 x 1-pole CA5
or 1 x TEF5
+ 1 x 1-pole CA5
or 1 x TEF5
+ 2 x 1-pole CA5
or 1 x TEF5
+ 2 x 1-pole CA5
–
+ 2 x 1-pole CA5 or CE5 (1)
or 1 x 4-pole CA5
VE5
–
+ 2 x 1-pole CA5 or CE5 (1)
–
–
–
+ 1 x CAL5-11
–
x CA5
x CE5
to 2 x CA5
to 2 x CE5
–
–
+ 1 to 2 x CAL5-11
–
–
–
+ 1 to 2 x CAL5-11
–
1 to 2 x CA5
1 to 2 x CE5
–
–
+ 1 to 2 x CAL18-11
or 1 to 2 x CEL18
–
1
1
1
1
1
1
1
1
1
1
1
1
to
to
to
to
to
to
to
to
6
5
6
5
6
5
6
5
x
x
x
x
x
x
x
x
CA5
CE5 max.
CA5
CE5 max.
CA5
CE5 max.
CA5
CE5 max.
(2)
(2)
(2)
(2)
or 1 x 4-pole CA5
+ 2 x 1-pole CA5 or CE5 (2)
or 1 x 4-pole CA5
+ 2 x 1-pole CA5 or CE5 (2)
or 1 x 4-pole CA5
+ 2 x 1-pole CA5 or CE5 (2)
or 1 x 4-pole CA5
+ 2 x 1-pole CA5 or CE5 (2)
or 1 x TEF5
+ 1 to 2 x CAL5-11
+ 1 x CAL5-11
or 1 x VE5-2
+ 1 x CAL5-11
or 1 x VE5-2
+ 1 x CAL5-11
or 1 x VE5-2
+ 2 x 1-pole CA5
or 1 x TEF5
+ 2 x 1-pole CA5
or 1 x TEF5
+ 2 x 1-pole CA5
or 1 x TEF5
–
–
+ 2 x 1-pole CA5
Notes regarding combination of CE5 with other accessories:
(1) The total number of N.O. or N.C. CE5 and other additional N.C. CA5 auxiliary contacts is limited to 3. CES auxiliary contacts not allowed in mounting position 5.
(2) The total number of N.O. or N.C. CE5 and other additional N.C. CA5 auxiliary contacts is limited to 5.
1SBC101585S0201 - Rev. A
5
1 0
Side-mounted accessories
Auxiliary contact blocks Interlock unit
5/370 | ABB
Function markers
Mounting piece
BA5-50 Function markers
1SBC575874F0301
Description
BA5-50
Set of 50 function markers designed to be clipped onto the front face of devices. Details can be added to
these markers using a ball point pen, indelible felt-tip pen or pentel white.
Self-adhesive labels (not supplied) can also be added to them.
Marker dimensions: 7 x 19 mm (0.276" x 0.748").
Ordering details
For contactors
Type
Order code
Pkg
qty
UA, UA..RA and accessories
GA75, GAE75
BA5-50
1SBN110000R1000
1
Weight
(1 pce)
kg
0.017
5
1SBC586724F0302
BP16 Mounting piece
Description
Mounting piece for screw fixing (M4, not supplied) of UA, UA..RA series contactors indicated in the table
below.
Easy handling of screwdrivers and screw driving.
Add-on mounting piece on contactor's rear face, offering a wide fixing facility.
Ordering details
Type
Order code
Pkg
qty
UA16, UA16..RA
BP16
1SBN111403R1000
100
35 1.38"
Weight
(1 pce)
kg
0.141
ø 4.5 0.18"
M4 8-32 UNC
4.5 0.18"
1SBC101531S0201 - Rev. B
84 3.31"
BP16
For contactors
4.5 0.18"
Drilling plan for UA16, UA16..RA
contactors with BP16
ABB | 5/371
Surge suppressors for contactor coils
Description
(V)
1000
T (µs)
0
100
1000
100
1SBC574001F0301
A 884D
0
5
1SBC573891F0301
RV5/50
RC5-1/50
The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil.
The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form
of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are
observed ranging from interference on the electronic devices to breakdown of insulators and even destruction of certain sensitive components.
The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz
coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.
Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of
3500 V.
Overvoltage Factor
The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak
value Ûc of the coil rated control voltage Uc:
Ûs max.
Ûs max.
Ûs max.
k =
in DC: k =
or in AC: k =
Ûc
Uc
Uc√2
3500
For example the following is obtained for the above graph: k =
≈ 60
42
√2
To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppressors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping
voltage frequencies.
Each case is different, but the technical data tolerances and the generous sizing of parts have enabled us
to reduce the number of variants.
We have chosen the following solutions: transil diodes, varistors and RC blocks.
Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.
Ordering details
For contactors
UA, UA..RA
GA75, GAE75
UA, UA..RA
GA75
Type
Order code
Pkg
qty
Weight
(1 pce)
V
24...50
AC
●
DC
● RV5/50
1SBN050010R1000
2
kg
0.015
50...133
●
●
RV5/133
1SBN050010R1001
2
0.015
110...250
●
●
RV5/250
1SBN050010R1002
2
0.015
250...440
●
●
RV5/440
1SBN050010R1003
2
0.015
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
●
●
●
●
–
–
–
–
–
–
–
–
–
●
●
●
●
●
RC5-2/50
RC5-2/133
RC5-2/250
RC5-2/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050200R1000
1SBN050200R1001
1SBN050200R1002
1SBN050200R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
1SBC101527S0201 - Rev. B
GAE75
Rated control circuit
voltage
Uc
5/372 | ABB
Surge suppressors for contactor coils
Technical data
Varistor
RV5/50
RV5/133
RV5/250
RV5/440
24...50 V AC
50...133 V AC
110...250 V AC
250...440 V AC
24...50 V DC
50...133 V DC
110...250 V DC
250...440 V DC
132 V AC
270 V AC
480 V AC
825 V AC
132 V DC
270 V DC
480 V DC
825 V DC
1.1...1.5
-20...+70 °C
Clip-on for both fixing and connection.
Clipped onto the top part of the contactor base without change in contactor overall dimensions.
High energy absorption: good damping - Unpolarized system.
Clipping as from Uvdr*, thus voltage front up to this point.
*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10 %.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Connection to the coil terminals (parallel mounting)
Fixing
Advantages
Drawback
5
RC type
RC5-2/50
RC5-2/133
RC5-2/250
RC5-2/440
24...50 V AC
50...133 V AC
110...250 V AC
250...440 V AC
2 to 3 x Uc max.
1.2...1.3
-20...+70 °C
Clip-on for both fixing and connection.
Clipped onto the top part of the contactor base without change in contactor overall dimensions.
Very fast clipping - Attenuation of steep fronts and thus of high frequencies. No operating delays.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Connection to the coil terminals (parallel mounting)
Fixing
Advantages
Transil diode
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
12...32 V DC
25...65 V DC
50...90 V DC
77...150 V DC
150...264 V DC
50 V DC
100 V DC
150 V DC
210 V DC
390 V DC
1.5...3
-20...+70 °C
Clip-on for both fixing and connection.
Clipped onto the top part of the contactor base without change in contactor overall dimensions.
Good energy absorption - Unpolarized system - Simple, reliable system.
A certain delay on drop out which does not however reduce contactor breaking capacity.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Connection to the coil terminals (parallel mounting)
Fixing
Advantages
Drawback
Wiring diagrams
E0734D
A2
Varistor
A2
RC type
A2
E0733D
A1
A1
E0735D
A1
Transil diode
E0844D
The add-on block does not increase the
contactor overall dimensions
1SBC101335S0201 - Rev. A
Dimensions
RV5, RC5, RT5
ABB | 5/373
1SBC101005F0014
Interface relays
RA5-1
5
Description
RA5-1 interface relay is designed to receive 24 V DC signals delivered by PLC’s or other sources with a
low output power and to restore them with sufficient power to operate the coils of the relevant contactors.
RA5-1 interface relay is made up of a miniature electromechanical relay equipped with a N.O. contact and
with a low consumption 24 V DC coil.
The interface relay coil is controlled by the PLC while the N.O. contact ensures switching of the power
contactor.
Coil switching gives rise to overvoltages which have adverse effects on the electronic devices, insulators
and, more generally, on component lifetime. The RA5-1 is equipped with surge suppressors:
– – on the 24 V DC relay coil via a diode,
– – on the power contactor coil via a varistor.
Furthermore, the RA5-1 is protected against relay pole reversal by a diode inserted between the E1 and
E2 input terminals.
Ordering details
For contactors
V 50/60 Hz
24...250
Rated control circuit
voltage
Uc
V DC
24
Type
Order code
Pkg
qty
Weight
(1 pce)
RA5-1
RA5-1
1SBN060300R1000
1SBN060300T1000
1
10
kg
0.050
0.050
1SBC101528S0201 - Rev. B
UA, UA..RA
GA75
Coil voltages
5/374 | ABB
Interface relays
Technical data
Type
RA5-1
Utilization characteristics according to IEC
Standards
IEC 60255-5
Rated insulation voltage Ui acc. to IEC 60947-4-1
250 V AC
Ambient air temperature
at Uc = 24 V DC (between E1 and E2) -25…+70 °C
In free air operation
from 0.85 to 1.1 x Uc -25…+55 °C
Storage
-40…+70 °C
Climatic withstand
Complies with that of associated contactors
Maximum operating altitude
3000 m
Mounting positions
No limitation
Fixing
Using the contactor A1 and A2 teminal connecting parts
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
1x
2x
1x
2x
L<
l>
Flexible with ferrule
l L
Lugs
Tightening torque
Recommended
Max.
Degree of protection
5
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.5 mm
1 Nm
1.2 Nm
Protection against direct contact in acc. with EN 50274
RA5-1 wired and mounted on the associated contactor
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
Working data
Surge suppression
For contactor coil
For interface relay coil
Protection against polarity reversal between terminals E1 and E2
Interface relay operating time
Total operating time, interface relay + contactor
N.O. contact closing
Between energization and:
N.C. contact opening
N.O. contact opening
N.C. contact closing
Between de-energization and:
Varistor
Diode
Diode
Closing and drop-out ≤ 10 ms
20…37
17…32
17…25
20…28
ms
ms
ms
ms
Electrical input data
Control voltage (E1 and E2 terminals) Uc
Rated value
Max. range at ambient temperature 20 °C
Max. consumption for Uc = 24 V DC, θ = 20 °C
"0" status (relay open)
"1" status (relay closed)
Max. short supply interruption immunity time
24 V DC
19…30 V DC
0.3 W
for Uc ≤ 2.4 V DC
for Ic < 1 mA
for Uc ≥ 19 V DC
2 ms
Electrical output data
Switching voltage (A0 and A2 terminals)
Electrical durability
Number of operating cycles
≤ 250 V AC
2 millions (600 cycles/h) on UA16(RA) ... UA75(RA), GA75, GAE75 contactors
0.5 million (600 cycles/h) on UA95(RA) and UA110(RA) contactors
The "E1+" and "E2-" input terminals must be connected, according to their polarity, to the PLC
output.
The RA5-1 is equipped with two terminal pads for connection to the A1 and the A2 terminals of the
contactor coil.
This coil is supplied between the A0 and the A2 terminals of the RA 5-1.
Mounting: terminals pads clamped inside the contactor coil terminals.
PLC
Output
Uc
≤ 250 V AC
–
A2
E2 –
A0
24 V DC
+
E1 +
RA 5-1
KM1
A2
E0742DG
A1
ABB | 5/375
1SBC101337S0201 Rev. A
Connection
Mechanical latching units
1SBC565483F0301
Description
WB75-A
E1
E2
E2676D
5
Terminal marking
For converting standard contactors into latched contactors.
The WB75-A block contains a mechanical latching device with electromagnetic impulse unlatching (AC or
DC) or manual unlatching.
Captive screw type connecting terminals, built-in cable clamps, M3.5 (+,-) pozidriv 2 screw with screwdriver guidance; delivered untightened and protected against accidental direct c ontact.
Operation
After closing, the contactor continues to be held in the closed position by the latching mechanism should
the supply voltage fail at the contactor coil terminals.
Contactor opening can be controlled:
– – electrically by an impulse (AC or DC) on the WB75-A block coil.
(the coil is not designed to be permanently energized)
–– manually by pressing the pushbutton on the front face of the WB75-A block.
Mounting
The WB75-A block is clipped onto the front face of the 1-stack contactor where it takes up two slots. The
two other slots may accept CA5... single pole auxiliary contacts (1 block on each side of the mechanical
latch).
Ordering details
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
WB75-A
FPTN372726R1001
FPTN372726R1002
FPTN372726R1003
FPTN372726R1004
FPTN372726R1006
FPTN372726R1005
FPTN372726R1007
FPTN372726R1008
1
1
1
1
1
1
1
1
kg
0.120
0.120
0.120
0.120
0.120
0.120
0.120
0.120
1SBC101526S0201 - Rev. B
UA16 ... UA75,
GA75, GAE75
Rated control circuit
voltage
Uc
V 50 Hz
or DC
V 60 Hz
24
24...28
42
42...48
48
48...55
110
110...127
220...230
220...255
230...240
230...277
380...415
380...440
415...440
440...480
5/376 | ABB
Mechanical latching units
Technical data
Type
WB75-A
Utilization characteristics according to IEC
Rated insulation voltage Ui acc. to IEC 60947-1
Max. electrical impulse time
On AC coil (with load factor 5 %)
On DC coil (with load factor 3 %)
Min. electrical impulse time
For latching (energizing of the contactor coil)
690 V
20 s
8s
AC
DC
AC
For pull-out (energizing of the WB block coil)
DC
AC or DC supply
Coil operating limits
AC control voltage 50/60 Hz
Rated control circuit voltage Uc
Coil consumption
50 ms (UA, GA contactors)
50 ms (GAE contactors)
30 ms (UA, GA contactors)
50 ms (GAE contactors)
0.85…1.1 x Uc
5
24…480 V AC
Average pull-in value 90 VA
Average holding value 60 VA
DC control voltage
Rated control circuit voltage Uc
Coil consumption
Average pull-in value
Average holding value
24…440 V DC
110 W
110 W
Operating time
On contactor closing (latching)
Between coil energization and:
N.O. contact closing
N.C. contact opening
No difference with the operation of a contactor without mechanical latching unit
No difference with the operation of a contactor without mechanical latching unit
N.O. contact opening
N.C. contact closing
5…25 ms
7…28 ms
On contactor opening (unlatching)
Between WB coil energization and:
Mechanical durability
Number of operating cycles
Max. switching frequency
1 million operating cycles
3600 cycles/h with on-load factor of 8 %
Connecting characteristics
1x
2x
1x
2x
L<
l>
Flexible with ferrule
l L
Lugs
Tightening torque
Screw terminals
All terminals
Screwdriver type
Recommended
Max.
1...4 mm²
1...4 mm²
0.75...2.5 mm²
0.75...2.5 mm²
8 mm
3.5 mm
1 Nm
1.2 Nm
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1SBC101333S0201 - Rev. B
Connection capacity (min. ... max.)
Rigid solid
ABB | 5/377
1SBC580742F0301
Additional terminal blocks and other accessories
Terminal blocks
Description
The LD terminal blocks are designed to increase the connecting capacity of the contactor on which they
are fitted and for preparation of the wiring before final connection on the contactor.
The LD blocks are 3-pole terminal blocks with tunnel terminals.
The LD75 terminal blocks are fixed in the 3 independent slots located above the built-in connectors.
LD75
Ordering details
5
For contactors
Type
Order code
Pkg
qty
UA50(RA) ... UA75(RA)
LD75
1SBN073508R1000
1
Weight
(1 pce)
kg
0.115
Technical data
Types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Main terminals
LD75
690 V
600 V
Screw terminals with single connector
10x11 mm
Connection capacity (min. ... max.)
Rigid
Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with ferrule
Bars
Tightening torque
Degree of protection
1x
2x
1x
2x
6...50 mm²
6...25 mm²
6...35 mm²
6...16 mm²
10 mm
4 Nm
IP10
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Delivered in closed position
M6
Screwdriver type pozidriv 2
Screw terminals
Note: The utilization of LD additional terminal blocks leaves the possibility to connect the following cables
directly into the contactor main terminals.
Possible cross section of rigid cable in the contactor
terminals
LD75
50 mm²
1SFT98000-011C3
Terminal enlargements
Description
Enlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger
connections to be mounted.
Sets containing 3 tin plated copper bars fixed by an isolating spacer.
5/378 | ABB
For contactors
Dimensions
UA95, UA110
hole Ø
mm
6.5
bar
mm
15 x 3
Type
Order code
Pkg
qty
Weight
(1 pce)
LW110
1SFN074307R1000
1
kg
0.100
1SBC101534S0201 - Rev. B
Ordering details
LW
Terminals for control lead connections
1SBC575763F0301
Description
1SBC575773F0301
LK75-L
Terminals designed to connect the control conductors to the main poles of the UA and GA contactors and
derivative versions.
Accessories clipped into the slots placed above each power terminal connector.
The LK75 are fitted with a pin designed to hold them in place until the connector has been fully clamped
with its power cable.
– – Degree of protection IP20
– – Connecting terminal delivered in open position: cable clamp and M3.5 (+,-) pozidriv 2 screw.
– – Cable cross-sectional area:
-- 1 or 2 rigid conductors...........................................1...4 mm²
-- 1 or 2 flexible conductors with cable end................0.75...2.5 mm²
– – Tightening torque for the LK screw:
-- recommended........................................................1.00 Nm
-- maxi.......................................................................1.20 Nm
5
LK75-F
Ordering details
For contactors
Type
Order code
Pkg
qty
Right and left on:
UA50(RA) ... UA75(RA)
GA75, GAE75
LK75-L
1SBN073552R1003
2
Weight
(1 pce)
kg
0.006
Opposite on:
UA50(RA) ... UA75(RA)
GA75, GAE75
LK75-F
1SBN073552R1002
2
0.006
Note: The LK terminals provided for the UA contactors can be used with the AM types.
LK positioning
19 0.75"
11 0.43"
13 0.51"
13 0.51"
13 0.51"
mm, inches
LK75-L
LK75-F
19 0.75"
1SBC101535S0201 - Rev. B
Main dimensions
ABB | 5/379
Contactor coils and main contact sets
Contactor coils
1SBC573802F0302
Ordering details
ZA16
For contactors
UA16,
UA16..RA
UA26, UA30,
UA26..RA, UA30..RA
5
UA50 … UA75
UA50..RA ... UA75..RA
GA75
UA95, UA110
UA95..RA, UA110..RA
Rated control circuit
voltage
Uc
V 50 Hz
V 60 Hz
24
24
48
48
110
110…120
220…230
230…240
230...240
240…260
380…400
400…415
400…415
415…440
24
24
48
48
110
110…120
220…230
230…240
230...240
240…260
380…400
400…415
400…415
415…440
24
24
48
48
110
110…120
220…230
230…240
230...240
240…260
380…400
400…415
400…415
415…440
24
24
48
48
110
110…120
220…230
230…240
230...240
240…260
380…400
400…415
400…415
415…440
Type
Order code
Pkg
qty
Weight
(1 pce)
ZA16
ZA16
ZA16
ZA16
ZA16
ZA16
ZA16
ZA40
ZA40
ZA40
ZA40
ZA40
ZA40
ZA40
ZA75
ZA75
ZA75
ZA75
ZA75
ZA75
ZA75
ZA110
ZA110
ZA110
ZA110
ZA110
ZA110
ZA110
1SBN151410R8106
1SBN151410R8306
1SBN151410R8406
1SBN151410R8006
1SBN151410R8806
1SBN151410R8506
1SBN151410R8606
1SBN152410R8106
1SBN152410R8306
1SBN152410R8406
1SBN152410R8006
1SBN152410R8806
1SBN152410R8506
1SBN152410R8606
1SBN153510R8106
1SBN153510R8306
1SBN153510R8406
1SBN153510R8006
1SBN153510R8806
1SBN153510R8506
1SBN153510R8606
1SFN154310R8106
1SFN154310R8306
1SFN154310R8406
1SFN154310R8006
1SFN154310R8806
1SFN154310R8506
1SFN154310R8606
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
kg
0.093
0.093
0.093
0.093
0.093
0.093
0.093
0.148
0.148
0.148
0.148
0.148
0.148
0.148
0.166
0.166
0.166
0.166
0.166
0.166
0.166
0.170
0.170
0.170
0.170
0.170
0.170
0.170
Main contact sets
Description
The contact sets for 3-pole contactors consists of six fixed contacts, three moving contacts, springs and
the required screws.
Ordering details
Type
Order code
Pkg
qty
UA50
UA63
UA75
UA95
UA110
ZLU50
ZLU63
ZLU75
ZLU95
ZLU110
1SBN163502R1000
1SBN163702R1000
1SBN164102R1000
1SFN164302R1000
1SFN164502R1000
1
1
1
1
1
Weight
(1 pce)
kg
0.115
0.145
0.145
0.190
0.190
1SFC101143C0201 - Rev A
For contactors
5/380 | ABB
Accessories for EK550, EK1000 contactors
Auxiliary contact blocks
5/382
Mechanical interlock units, terminal shrouds and connection sets 5/386
Surge suppressors for contactor coils
5/388
Main contact sets - Arc chutes
5/390
Contactor coils
5/391
Summary_5-11
5
ABB | 5/381
Auxiliary contact blocks
Description
E2074D
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.
Mounting positions
of the CAL16-11
Types of auxiliary contact blocks for standard industrial environments:
–– CAL instantaneous with N.O. + N.C. contacts
–– CCL N.O. leading contact + N.C. lagging contact.
The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected
against accidental direct contact, and bear the corresponding function m
arking.
Mounting: Screwed onto the right and / or lefthand side of the EK550, EK1000 contactors.
Ordering details
For contactors
Number
of blocks
Auxiliary contacts
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
5
2-pole auxiliary contacts N.O. + N.C.
1
1 1
EK
1
1 1
1
1 1
1
1 1
1
1 –
–
–
–
–
–
–
–
–
–
1
CAL16-11A
CAL16-11B
CAL16-11C
CAL16-11D
CCL16-11E (1)
SK829002-A
SK829002-B
SK829002-C
SK829002-D
SK829002-E
1
1
1
1
1
0.050
0.050
0.050
0.050
0.050
1SFC101221C0201
(1) Mounting of CCL16-11E blocks does not allow an additional second block to be added on top of it.
All DC operated EK contactors are equipped with one CCL16-11E on the right side.
5/382 | ABB
Auxiliary contact blocks
Technical data
2-pole CAL 16-11, 2-pole CCL 16-11
Types
Contact utilization characteristics according to IEC
IEC 60947-5-1 and EN 60947-5-1
690 V
24...690 V
10 A
50/60 Hz
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Rated frequency (without derating)
Ie / Rated operational current AC-15
24-127 V
220-240 V
380-440 V
500-690 V
acc. to IEC 60947-5-1
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
6A
6A
4A
1A
10 x Ie AC-15
10 x Ie AC-15
5
6A
6A
4A
1.8 A
0.6 A
10 A
for 1.0 s 50 A
for 0.1 s 100 A
0.25 VA / 12 V or 0.25 VA / 5 mA
24 V DC
48 V DC
72 V DC
125 V DC
250 V DC
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Electrical durability
Number of operating cycles
Max. switching frequency
0.2 W
10 millions operating cycles
3600 cycles/h
see "Electrical durability" curves
1200 cycles/h
Contact utilization characteristics according to UL / CSA
600 V
A600
Max. operational voltage
Pilot duty
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with ferrule
Flexible with insulated ferrule
L
Lugs
6
Tightening torque
Recommended
Max.
Degree of protection
1x
2x
1x
2x
1x
2x
L≤
l>
0.5...2.5 mm²
0.5...2.5 mm²
0.5...2.5 mm²
0.5...2.5 mm²
0.5...1.5 mm²
0.5...1.5 mm²
8 mm
3.7 mm
1.00 Nm
1.20 Nm
IP20
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Delivered in open position, screws of unused terminals must be tightened
M3.5
Pozidriv 2
1SBC101656S0201
Screw terminals
All terminals
Screwdriver type
ABB | 5/383
Auxiliary contacts
Electrical durability
Electrical Durability for AC-15 Utilization Category
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
This curve represents the electrical durability of the auxiliary contacts in relation to the breaking current.
The curve has been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.
30
20
10
3
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2
3 4 5 6
10
Breaking current (A)
2-pole CAL16... and CCL16... auxiliary contact blocks
Electrical Durability for DC-13 Utilization Category
DC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making and breaking current = Ie with Ue value.
100
70
50
6
1.10 cycles
6
Breaking power (W)
3.10 cycles
20
6
10.10 cycles
10
Example:
Control of d.c. electro-magnet: Ue voltage = 72 V d.c. and
breaking power = 70 W.
On the opposite curve at intersection "O" 72 V / 70 W the
correspon-ding value for the electrical durability is approximately 2.106 cycles.
5
2
1
10
20 24
50
72
100
200 250
500
Voltage (V)
2-pole CAL16... and CCL16... auxiliary contact blocks
1SBC101657S0201
5
Million operating cycles
5
5/384 | ABB
Add-on auxiliary contacts
Terminal marking and positioning
2-pole auxiliary contacts
14
21
31
NC
NC
22
32
CAL16-11A
43
NO
44
CAL16-11B
53
NO
54
61
71
83
35
47
NC
NC
NO
NC
NO
62
72
84
36
48
CAL16-11C
CAL16-11 D
CAL16-11E
5
1SBC101687S0201
13
NO
ABB | 5/385
Mechanical interlock units, terminal shrouds and
connection sets
Mechanical interlock units
A090C4
Description
The mechanical interlock unit prevents one of the contactors from closing as long as the other
contactor is closed.
VH800 interlock unit is used for the mechanical interlocking of two horizontal mounted EK550, EK1000
contactors. Mounting plate is included.
Ordering details
For contactors
Type
Order code
Mechanical interlock unit for two horizontal mounted contactors
EK550, EK1000
VH800
SK829070-F
5
Pkg
qty
Weight
(1 pce)
kg
1
6.000
Terminal shrouds
Description
The use of terminal shrouds on the main terminals of EK contactors is required in electrical panels or
cubicles to be built in compliance with the rules for protection against direct contact with live parts in acc.
with EN 50274.
On EK550, EK1000 contactors:
– – The auxiliary contact blocks and coils are designed to provide an IP20 degree of protection
– – The main terminals, equipped with lugs or connectors, can be protected against accidental direct contact after wiring (EN 50274) by the addition of terminal shrouds (see table below).
Each terminal shroud protects all the terminals on one side of the contactor. Two terminal shrouds should
be provided for each separate contactor.
Ordering details
A1
3
5
7
7
5
3
1
4
6
8
8
6
4
2
BSS550, BSS1000
Type
Order code
Pkg
qty
EK550
EK1000
LT550-EK
LT1000-EK
SK178001-LB
SK178001-MB
1
1
Weight
(1 pce)
kg
0.190
0.200
Connection sets
A1
Description
A2
E0747D
A2
1
2
For contactors
Connection between the main poles of two 4-pole contactors mounted side by side so that they operate
as source reversing contactors.
These sets are made up of four downstream connections.
BSS550, BSS1000 – Bare, solid copper bars.
For contactors
Type
Order code
Mechanical and electrical interlock units for two horizontal mounted contactors
EK550
BSS550
SK829090-E
EK1000
BSS1000
SK829090-H
5/386 | ABB
Pkg
qty
Weight
(1 pce)
kg
1
1
3.300
5.500
1SFC101222C0201
Ordering details
Mechanical interlocks units
Mechanical and electrical interlock units
Technical data
Types
VH145
VH300
Contact utilization characteristics according to IEC
IEC 60947-5-1 and EN 60947-5-1
690 V
600 V
24 ... 690 V
10 A
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated insulation voltage Ui acc. to UL / CSA
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
380-440 V 50/60 Hz
500-690 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device - gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
6A
6A
4A
1A
10 x Ie AC-15
10 x Ie AC-15
5
6A
6A
4A
1.8 A
0.6 A
10 A
for 1.0 s 100 A
for 0.1 s 140 A
0.15 W
24 V DC
48 V DC
72 V DC
125 V DC
250 V DC
1 million operating cycles
600 cycles/h
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with ferrule
l L
Bars or lugs
Tightening torque
Recommended
Max.
Degree of protection
1x
2x
1x
2x
L<
l>
1 ... 2.5 mm²
1 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
8 mm
3.7 mm
1 Nm
1.2 Nm
IP20
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screw terminals
All terminals
Screwdriver type
Delivered in open position, screws of unused terminals must be tightened
M3.5
Flat Ø 5.5 / Pozidriv 2
1SFC101073C0201
Technical note: when, during switching, the arc time is estimated to more than 40 ms, the closing signal of one of the two contactors must be delayed with respect to the opening
signal of the other contactor in order to prevent a short-circuit.
Use a TP40 pneumatic timer or TE5S electronic timer with time lapse, as applicable.
ABB | 5/387
Surge suppressors for contactor coils
Description
(V)
1000
T (s)
100
0
1000
100
A078
A 884D
0
RC-EH
Ordering details
For contactors
EK550, EK1000
EK550, EK1000
EK550, EK1000
Rated control circuit
voltage
Uc
V
AC
●
48...110
24...125
–
●
220...600
Type
DC
–
●
–
RC-EH800/110
RC-EH800/110
RC-EH800/600
Order code
SK829007-C
SK829007-C
SK829007-D
Pkg
qty
1
1
1
Weight
(1 pce)
kg
0.015
0.015
0.015
1SFC101223C0201
5
The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil.
The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form
of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are
observed ranging from interference on the electronic devices to breakdown of insulators and even destruction of certain sensitive components.
The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V / 50 Hz
coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.
Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of
3500 V.
Overvoltage Factor
The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak
value Ûc of the coil rated control voltage Uc:
Ûs max.
Ûs max.
Ûs max.
k =
in DC: k =
or in AC: k =
Ûc
Uc
Uc√2
3500
For example the following is obtained for the above graph: k =
≈ 60
42
√2
To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppressors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping
voltage frequencies.
Each case is different, but the technical data tolerances and the generous sizing of parts have enabled us
to reduce the number of variants.
We have chosen the following solutions: transil diodes, varistors and RC blocks.
Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.
5/388 | ABB
Surge suppressors for contactor coils
Technical data
Varistor + RC
RC-EH800/110
RC-EH800/600
48...110 V AC
220...600 V AC
24...125 V DC
–
205 V AC
1100 V AC
205 V DC
–
1.1 ... 1.15
-20 ... +70 °C
Flexible, accessible leads, equipped with forked lugs
Glued to the top part of the contactor base
- High energy absorption: good damping
- Unpolarized system
- The RC system damps the voltage front under the Uvdr (1) threshold.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Connection to the coil terminals (parallel mounting)
Fixing
Advantages
(1) Uvdr = Varistor operating (voltage dependant resistor), tolerance ±10 %.
5
Wiring diagrams
A2
E0736D
U
A1
Varistor + RC
mm
30
Main dimensions
57.5
15
E0845D
175
1SFC101224C0201
RC-EH
ABB | 5/389
Main contact sets
Arc chutes
Main contact sets
1SBC586473F0304
Description
KZK
The contact sets for 4-pole contactors consist of eight fixed contacts, four moving contacts, springs and
the necessary screws. In addition, the sets include four moving arcing contacts for EK550, EK1000 contactors.
Ordering details
For contactors
Type
Order code
Pkg
qty
EK550
EK1000
KZK550
KZK1000
SK827204-B
SK827204-F
1
1
Weight
(1 pce)
kg
2.400
3.000
5
Arc chutes
Description
The arc chutes sets for EK 4-pole contactors contain 8 pieces.
Ordering details
Type
Order code
Pkg
qty
EK550
EK1000
KWK550
KWK1000
5223351-Z
5223351-AN
1
1
Weight
(1 pce)
kg
3.170
3.170
1SFC101226C0201
For contactors
5/390 | ABB
Contactor coils
For AC operated coil
Coils for EK550, EK1000 - AC operated.
Ordering details
For contactors
KH300
EK550, EK1000
Rated control circuit
voltage
Uc
(1)
V 50 Hz
V 60 Hz
48
110
110...120
110...115
115...127
220
220...240
220...230
230...255
380
380...415
380…400
400...440
400…415
-
Type
Order code
Pkg
qty
Weight
(1 pce)
KH800
KH800
KH800
KH800
KH800
KH800
KH800
KH800
SK828100-AD
SK828100-EF
SK828100-EG
SK828100-EL
SK828100-EM
SK828100-EP
SK828100-ER
SK828100-AR
1
1
1
1
1
1
1
1
kg
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
5
(1) Other control voltages, see voltage code table.
For DC operated coil
Description
Coils for EK550, EK1000 - DC operated with sets including a DC coil, an economy resistor and a insertion
contact.
Ordering details
For contactors
Rated control circuit
voltage
Uc
Type
Order code
Pkg
qty
Weight
(1 pce)
KP800
KP800
KP800
KP800
KP800
KP800
KP800
KP800
SK828150-DB
SK828150-DC
SK828150-DD
SK828150-DT
SK828150-DG
SK828150-DE
SK828150-DU
SK828150-DF
1 set
1 set
1 set
1 set
1 set
1 set
1 set
1 set
kg
1.060
1.060
1.060
1.060
1.060
1.060
1.060
1.060
(1)
EK550, EK1000
V DC
24
36
48
60
75
110
125
220
(1) Other control voltages, see voltage code table.
1SFC101227C0201
1SBC273813F0302
Description
ABB | 5/391
Voltage code table
The below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give
the order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the order code according to the table below. Example: for contactor AF400-30-11 and coil 100...250 V 50/60 Hz, the order code is 1SFL577001R7011.
AF09 ... AF370 3-pole contactors
AF09 ... AF370 4-pole contactors
Auxiliary contacts
N.O. N.C.
Type
AF09 - 30 - 10 - 13
Order code
1SBL137001R 13 10
AC coil code
50/60 Hz
41 24...60 V
11 24...60 V
12 48...130 V
13 100...250 V
14 250...500 V
N.O. N.C.
Main contacts
5
AF..
Contactor type
AC / DC operated
DC coil code
20...60 V
48...130 V
100...250 V
250...500 V
Coil 41: not available for AF116 ... AF370
AF116 ... AF370 3-pole contactors
with built-in PLC interface
AC coil code
50/60 Hz
33 100...250 V
34 250...500 V
DC coil code
AC coil code
50/60 Hz
68 -
69 48...130 V
70 100...250 V
71 250...500 V
DC coil code
100...250 V
250...500 V
AF400 ... AF2650 3-pole contactors
Auxiliary contacts
N.O. N.C.
Type
AF400 - 30 - 11
Order code
1SFL577001R 69 11
N.O. N.C.
Main contacts
AF..
Contactor type
AC / DC operated
24...60 V
48...130 V
100...250 V
250...500 V
Coil 68, 69, 71: not available for AF1350 ... AF2650
AF09 ... AF38 3- and 4-pole contactors - low consumption
Low coil consumption
AF09 Z - 30 - 10 - 21
N.O. N.C.
Main contacts
AF..
Contactor type
AC / DC operated
5/392 | ABB
Order code
1SBL136001R 21 10
AC coil code
50/60 Hz
20 -
21 24...60 V
22 48...130 V
23 100...250 V
DC coil code
12...20 V
20...60 V
48...130 V
100...250 V
1SBC101601S0201 - Rev. C
Auxiliary contacts
N.O. N.C.
Type
Voltage code table
NF contactor relays
Type
Order code
1SBH137001R 13 22
NF 22 E - 13
AC coil code
50/60 Hz
41 24...60 V
11 24...60 V
12 48...130 V
13 100...250 V
14 250...500 V
N.O. N.C.
Number contacts
Contactor type
AC / DC operated
NF
DC coil code
20...60 V
48...130 V
100...250 V
250...500 V
5
NF contactor relays with overlapping of lagging / leading contacts
N.O. leading contacts
N.C. lagging contacts
Type
NF 33 / 11 - 13
Order code
1SBH137001R 13 39
N.O. N.C.
Number contacts
NF
Contactor type
AC / DC operated
AC coil code
50/60 Hz
41 24...60 V
11 24...60 V
12 48...130 V
13 100...250 V
14 250...500 V
DC coil code
AC coil code
50/60 Hz
20 -
21 24...60 V
22 48...130 V
23 100...250 V
DC coil code
20...60 V
48...130 V
100...250 V
250...500 V
NF contactor relays - low consumption
Low coil consumption
Type
Order code
NF Z 22 E - 21
1SBH136001R 21 22
N.O. N.C.
Number contacts
NF
Contactor type
AC / DC operated
12...20 V
20...60 V
48...130 V
100...250 V
NF contactor relays with overlapping of lagging / leading contacts - low consumption
Low coil consumption
N.O. leading contacts
NF Z 33 / 11 E - 21
N.O. N.C.
Number contacts
NF
Contactor type
AC / DC operated
Order code
1SBH136001R 21 39
AC coil code
50/60 Hz
20 -
21 24...60 V
22 48...130 V
23 100...250 V
1SBC101601S0201 - Rev. C
N.C. lagging contacts
Type
DC coil code
12...20 V
20...60 V
48...130 V
100...250 V
ABB | 5/393
Voltage code table
GA contactors
UA, UA..RA contactors
GA contactors
Auxiliary contacts
N.O. N.C.
Type
GA75 - 10 - 00
Order code
1SBL411025R 82 00
N.O. N.C.
Main contacts
5
GA
GAE
Contactor type
DC switching - AC operated
DC switching - DC operated
Contactors: UA, UA..RA, GA
AC coil code
50 Hz
60 Hz
81 24 V
24 V
16 26 V
28 V
17 28 V
32 V
82 42 V
42 V
20 42 V
48 V
83 48 V
48 V
73 60 V
60 V
74 100 V
100...110 V
26 105 V
110...127 V
84 110 V
110...120 V
89 110...115 V
115...127 V
29 120 V
140 V
30 125...127 V
150 V
34 175 V
208 V
36 190 V
220 V
40 210 V
240 V
80 220...230 V
230...240 V
88 230...240 V
240...260 V
42 230...240 V
277 V
85 380...400 V
400...415 V
86 400...415 V
415...440 V
50 400 V
440 V
51 400...415 V
480 V
87 415...440 V
440...460 V
53 440 V
500 V
55 500 V
600 V
56 550 V
58 660...690 V
59 -
690 V
Contactors: GAE
DC coil code
80
81
82
83
21
84
85
86
87
88
89
38
12 V
24 V
42 V
48 V
50 V
60 V
75 V
110 V
125 V
220 V
240 V
250 V
Codes in bold for dual frequency coils.
EK550, EK1000 contactors
EK550 - 40 - 11
N.O. N.C.
Main contacts
Contactor type
EK AC operated or DC operated
5/394 | ABB
Order code
SK827041
- AD
AD
AE
AF
AG
AZ
AH
AK
AL
AM
AN
AP
AR
AS
AT
AU
AV
AC coil code
50 Hz
48 V
-
110 V
127 V
-
190 V
-
220...230 V
230...240 V
-
380...400 V
400...415 V
-
440 V
500 V
-
60 Hz
110 V
120 V
208 V
220 V
240 V
240 V
380 V
440 V
480 V
600 V
EF
EG
EL
EM
EP
ER
Dual frequency coil code
50 Hz
60 Hz
110 V
110...120 V
110...115 V
115...127 V
220 V
220...240 V
220...230 V
230...255 V
380 V
380...415 V
380...400 V
400...440 V
2 auxiliary contact blocks maximum per
contactor, ambient temperature ≤ 55 °C
and mounting positions 2 and 6 excluded.
DC coil code
DB
DC
DD
DT
DG
DE
DU
DF
24 V
36 V
48 V
60 V
75 V
110 V
125 V
220 V
1SBC101601S0201 - Rev. C
Auxiliary contacts
N.O. N.C.
Type
Voltage code table
GAF185 ... GAF300 contactors
Type
Auxiliary contacts
N.O. N.C.
GAF185 - 10 - 11
Order code
1SFL497025R 69 11
N.O. N.C.
Main contacts
GAF
AC coil code
50/60 Hz
72 -
69 48...130 V
70 100...250 V
DC coil code
AC coil code
50/60 Hz
68 -
69 48...130 V
70 100...250 V
71 250...500 V
DC coil code
AC coil code
50/60 Hz
70 100...250 V
DC coil code
20...60 V
48...130 V
100...250 V
5
Contactor type
AC / DC operated
GAF460 ... GAF1250 contactors
Type
Auxiliary contacts
N.O. N.C.
GAF460 - 10 - 11
Order code
1SFL597025R 69 11
N.O. N.C.
Main contacts
GAF
Contactor type
AC / DC operated
24...60 V
48...130 V
100...250 V
250...500 V
GAF1650, GAF2050 contactors
Auxiliary contacts
N.O. N.C.
GAF1650 - 10 - 11
N.O. N.C.
Main contacts
GAF
Order code
1SFL677025R 70 11
100...250 V
Contactor type
AC / DC operated
1SBC101601S0201 - Rev. C
Type
ABB | 5/395
Questionnaire for product specifications:
Block contactors
Tel.: .......................................................... e-mail: ..................................................
Segments: ................................................................................................................
Application
Control circuit
Type: .. .............................................. No of phases: ......
Utilisation category (AC/DC): ............ % AC4 if any: .......
Rated operational voltage Ue: .......... V
Cos j:............
Frequency:.......... Hz L/R: . ......... ms
Nominal current In:........................... A
Making current:................. A Breaking current: ......... A
continuous
temporary
intermittent
Duty:
Load factor (% of ON time): . ............. %
Number of cycles per hour: .............. or per year: . .........
Expected durability: ......................... operating cycles
Number of main poles N.O.: . ............ N.C.: ...................
Other information: .. .......................................................
Rated control Uc voltage:......... V
DC
AC f: ...... Hz
Minimum / maximum: ................... V to .................... V
Surge suppressor: ........................ type:.......................
Interface with PLC: ....................... mA
.............. V DC
Accessories: .................................................................
Number of auxiliary contacts: N.O.: .......... N.C.: ..........
AC
Low level contacts: ............... mA .......... V DC
Short circuit protection: ................................................
Circuit breaker
Manual motor starter
Type: Fuse
Max short circuit current: ........................................... A
Manual Motor
Motor protection: Overload relay
Starter Electronic overload relay
Installation
Ambient temperature: ...................................................
Ambient environment: ...................................................
Humidity: .................................................................. %
Chemical pollution: .......................................................
Other: ..........................................................................
Mounting position, see drawing below (Position 6:
please consult factory): .................................................
Pos. 2
+30°
Logistic and packaging
Quantity by batch: ........................................................
Delivery order: ..............................................................
Expected quantity: ........................................... per year
Expected first delivery date: ............... and Qty: .............
Quantity on first 6 month: ............. on first year: .............
-30°
Pos. 4
Approvals and other requirements
Pos. 3
Pos. 1
Protection
Pos. 1 ± 30°
Pos. 5
Pos. 6
Wiring: Clamping screws or cage connectors
Cable lugs (ring tongue)
Other:........................................... Cross section:.........
Additional comments:....................................................
Reference standards: ....................................................
Required approvals: ......................................................
Customer specifications: ...............................................
Shock and vibrations: ...................................................
Specific quality assurance clauses: ................................
Other comments: ..........................................................
1SBC101701S0201
5
Tel.: .......................................................... e-mail: ...................................... .
Date: ......................................................
5/396 | ABB
Questionnaire for product specifications:
Block contactors
Other comments: .. .........................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
.....................................................................................................................................................................................
User Guide for the questionnaire
5
This document is used to define the contactor specifications according to the complete information on the application.
Do not hesitate to join some complementary documents if necessary (schemes, tables, customer specification…).
Please see below some definitions to help you :
Operating cycle
Includes one making operation and one breaking operation.
Electrical Durability
Number of on-load operating cycles that the contactor is able to carry out. It depends on the utilization category.
Mechanical Durability
Number of no-current operating cycles that the contactor is able to carry out
Load Factor
Ratio of the on-load operating time to the total cycle time x 100 (%).
Intermittent Duty
Duty during which the contactor is successively closed or open for periods which are too short to enable the contactor to achieve thermal balance.
Temporary Duty
Duty in which the main contacts of the contactor remain closed for periods insufficient to allow the equipment to reach stabilized temperature, the unload
periods being separated by off-load periods of sufficient duration to restore the ambient temperature
Continuous Duty
Duty in which the main contacts of the contactor remain closed, with a continuous current during enough time to reach thermal stabilization, but no more
than eight hours without interruption.
Ambient Temperature
Air temperature close to the contactor.
Mounting Position
Comply with the manufacturer's instructions. Restrictions could be taken into account for certain mounting positions.
A contactor's duty is characterized by the utilization category together with the rated operational voltage and current indicated:
Utilization categories for contactors according to IEC 60947-4-1
Utilization categories for contactor relays according to IEC 60947-5-1
See our catalog p7/8
Making and breaking current
Current at contactor closing or at contactor opening
1SBC101701S0201
Time constant L/R (for DC circuit)
Ratio of the inductance to the resistance (L/R = mH/Ω = ms)
ABB | 5/397
Summary_6
6
6/0 | ABB
AS..S, AF..S 3-pole contactors and
NS..S, NF..S contactor relays with spring terminals
AS..S 3-pole contactors - with spring terminals
6/3
Ordering details
6/4
Technical data
6/10
Electrical durability
6/16
Terminal marking and postioning
6/18
Main dimensions
6/20
Accessories
6/34
Voltage code table
6/41
NS..S contactor relays - with spring terminals
Ordering details
6/3
6/22
Technical data
6/26
Terminal marking and postioning
6/30
Main dimensions
6/32
Accessories
6/34
Voltage code table
6/41
AF..S 3-pole contactors - with spring terminals
6/43
Overview
6/44
Ordering details
6/46
Technical data
6/52
Electrical durability
6/57
Terminal marking and postioning
6/61
Main dimensions
6/62
Accessories
6/80
Voltage code table
6/88
NF..S contactor relays - with spring terminals
6/43
Overview
6/66
Ordering details
6/68
Technical data
6/74
Terminal marking and postioning
6/77
6/78
Accessories
6/80
Voltage code table
6/88
Summary_6
Main dimensions
6
ABB | 6/1
Summary_6-1
6
6/2 | ABB
AS..S 3-pole contactors and
NS..S contactor relays with spring terminals
AS..S 3-pole contactors - with spring terminals
AS09..S ... AS16..S
AC operated
6/4
ASL09..S ... ASL16..S
DC operated
6/5
AS09..S ... AS16..S
AC operated - 2-stack
6/6
ASL09..S ... ASL16..S
DC operated - 2-stack
6/7
Main accessories
6/8
Technical data
6/10
Electrical durability
6/16
Terminal marking and postioning
6/18
Main dimensions
6/20
NS..S contactors relays - with spring terminals
NS..S
AC operated
6/22
NSL..S
DC operated
6/23
Main accessories
6
6/24
Technical data
6/26
Terminal marking and postioning
6/30
Main dimensions
6/32
Accessories
6/34
Surge suppressors for contactor coils
6/38
Connecting links for starting solution and other accessories
6/40
Voltage code table
6/41
Summary_6-1
Auxiliary contact blocks - with spring terminals
ABB | 6/3
AS09..S ... AS16..S 3-pole contactors
4 to 7.5 kW
AC operated - with spring terminals
1SBC101009F0014
Description
AS09-30-10S
AS09 ... AS16 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and
220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
6
5.5
7.5
22
22
7.5
12
10
15.2
V 50 Hz
V 60 Hz
24
24
-
120
230
230
400
400
24
24
-
120
230
230
400
400
24
24
-
120
230
230
400
400
Auxiliary Type
contacts
fitted
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Order code
Weight
Pkg
(1 pce)
AS09-30-10S-20
AS09-30-01S-20
AS09-30-10S-16
AS09-30-01S-16
AS09-30-10S-26
AS09-30-01S-26
AS09-30-10S-28
AS09-30-01S-28
AS12-30-10S-20
AS12-30-01S-20
AS12-30-10S-16
AS12-30-01S-16
AS12-30-10S-26
AS12-30-01S-26
AS12-30-10S-28
AS12-30-01S-28
AS16-30-10S-20
AS16-30-01S-20
AS16-30-10S-16
AS16-30-01S-16
AS16-30-10S-26
AS16-30-01S-26
AS16-30-10S-28
AS16-30-01S-28
1SBL101004R2010
1SBL101004R2001
1SBL101004R1610
1SBL101004R1601
1SBL101004R2610
1SBL101004R2601
1SBL101004R2810
1SBL101004R2801
1SBL111004R2010
1SBL111004R2001
1SBL111004R1610
1SBL111004R1601
1SBL111004R2610
1SBL111004R2601
1SBL111004R2810
1SBL111004R2801
1SBL121004R2010
1SBL121004R2001
1SBL121004R1610
1SBL121004R1601
1SBL121004R2610
1SBL121004R2601
1SBL121004R2810
1SBL121004R2801
kg
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
AS09..S, AS12..S, AS16..S
6/4 | ABB
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
50 1.97"
5.5 0.22"
10 0.39"
60 2.36"
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
1SBC101454S0201
Main dimensions
ASL09..S ... ASL16..S 3-pole contactors
4 to 7.5 kW
DC operated - with spring terminals
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
V DC
24
48
110
220
5.5
22
7.5
12
24
48
110
220
7.5
22
10
15.2
24
48
110
220
Auxiliary Type
contacts
fitted
Order code
Weight
Pkg
(1 pce)
kg
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
ASL09-30-10S-81
ASL09-30-01S-81
ASL09-30-10S-83
ASL09-30-01S-83
ASL09-30-10S-86
ASL09-30-01S-86
ASL09-30-10S-88
ASL09-30-01S-88
ASL12-30-10S-81
ASL12-30-01S-81
ASL12-30-10S-83
ASL12-30-01S-83
ASL12-30-10S-86
ASL12-30-01S-86
ASL12-30-10S-88
ASL12-30-01S-88
ASL16-30-10S-81
ASL16-30-01S-81
ASL16-30-10S-83
ASL16-30-01S-83
ASL16-30-10S-86
ASL16-30-01S-86
ASL16-30-10S-88
ASL16-30-01S-88
1SBL103004R8110
1SBL103004R8101
1SBL103004R8310
1SBL103004R8301
1SBL103004R8610
1SBL103004R8601
1SBL103004R8810
1SBL103004R8801
1SBL113004R8110
1SBL113004R8101
1SBL113004R8310
1SBL113004R8301
1SBL113004R8610
1SBL113004R8601
1SBL113004R8810
1SBL113004R8801
1SBL123004R8110
1SBL123004R8101
1SBL123004R8310
1SBL123004R8301
1SBL123004R8610
1SBL123004R8601
1SBL123004R8810
1SBL123004R8801
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
6
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
72.5 2.85"
7 0.28"
5.5 0.22"
10 0.39"
2x
M4 8-32 UNC
35 1.38"
ø 4.2 0.17"
60 2.36"
45 1.77"
1SBC101455S0201
Main dimensions
35 mm EN/IEC 60715
ASL09-30-10S
ASL09..S ... ASL16..S contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 3 main poles and 1 built-in auxiliary contact
–– control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for
direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– add-on auxiliary contact blocks for front mounting and comprehensive range of accessories.
68 2.68"
1SBC101011F0014
Description
ASL09..S, ASL12..S, ASL16..S
ABB | 6/5
AS09..S ... AS16..S 2-stack 3-pole contactors
4 to 7.5 kW
AC operated - with spring terminals
1SBC101333F0014
Description
AS09-30-32S
AS09..S ... AS16..S contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC
and 220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact
–– 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block
–– the auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are
mirror contacts
–– control circuit: AC operated
–– a comprehensive range of accessories.
Ordering details
6
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
5.5
22
7.5
12
7.5
22
10
15.2
V 50 Hz
V 60 Hz
24
230
400
24
230
400
24
230
400
24
120
230
400
24
120
230
400
24
120
230
400
Auxiliary Type
contacts
fitted
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
AS09-30-32S-20
AS09-30-32S-16
AS09-30-32S-26
AS09-30-32S-28
AS12-30-32S-20
AS12-30-32S-16
AS12-30-32S-26
AS12-30-32S-28
AS16-30-32S-20
AS16-30-32S-16
AS16-30-32S-26
AS16-30-32S-28
Order code
Weight
Pkg
(1 pce)
1SBL101004R2032
1SBL101004R1632
1SBL101004R2632
1SBL101004R2832
1SBL111004R2032
1SBL111004R1632
1SBL111004R2632
1SBL111004R2832
1SBL121004R2032
1SBL121004R1632
1SBL121004R2632
1SBL121004R2832
kg
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
110.8 4.36"
72.5 2.85"
45 1.77"
10 0.39"
6/6 | ABB
1SBC101456S0201
AS09..S, AS12..S, AS16..S
5.5 0.22"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
ASL09..S ... ASL16..S 2-stack 3-pole contactors
4 to 7.5 kW
DC operated - with spring terminals
Ordering details
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
20
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc
rating
(1)
600 V AC
hp
5
A
12
5.5
22
7.5
12
7.5
22
10
15.2
Auxiliary Type
contacts
fitted
Order code
Weight
Pkg
(1 pce)
6
kg
V DC
24
48
110
220
24
48
110
220
24
48
110
220
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
ASL09-30-32S-81
ASL09-30-32S-83
ASL09-30-32S-86
ASL09-30-32S-88
ASL12-30-32S-81
ASL12-30-32S-83
ASL12-30-32S-86
ASL12-30-32S-88
ASL16-30-32S-81
ASL16-30-32S-83
ASL16-30-32S-86
ASL16-30-32S-88
1SBL103004R8132
1SBL103004R8332
1SBL103004R8632
1SBL103004R8832
1SBL113004R8132
1SBL113004R8332
1SBL113004R8632
1SBL113004R8832
1SBL123004R8132
1SBL123004R8332
1SBL123004R8632
1SBL123004R8832
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
Main dimensions
mm, inches
110.8 4.36"
72.5 2.85"
45 1.77"
10 0.39"
1SBC101457S0201
5.5 0.22"
35.4 1.39"
7 0.28"
35 mm EN/IEC 60715
ASL09-30-32S
ASL09..S ... ASL16..S contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC.
These contactors are of the block type design with:
–– spring terminals
–– 1st stack with 3 main poles and 1 N.O. built-in auxiliary contact
–– 2nd stack with permanently fixed 2 N.O. + 2 N.C. auxiliary contact block
–– the auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are
mirror contacts
–– control circuit: low consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for
direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– a comprehensive range of accessories.
68 2.68"
1SBC101335F0014
Description
ASL09..S, ASL12..S, ASL16..S
ABB | 6/7
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Main accessories
Contactor and main accessories (other accessories available)
VM3
CA3..S
AS..S
ASL..S
Contactors
RV5, RC5-1 or RT5
6
CA3..S
AS..S
ASL..S
Contactors
Main accessory fitting details
Contactor
types
Main
poles
Built-in
auxiliary
contacts
Front-mounted accessories
Auxiliary contact blocks
Side-mounted accessories
Mechanical
interlock unit
(between 2 contactors)
1-pole CA3..S
3
3
3
3
3
3
0
0
0
0
0
0
1
0
3
1
0
3
0
1
2
0
1
2
VM3
Surge suppressors
2 max.
+
1
+
RV5
or RC5-1
–
2 max.
+
1
1
+
+
RV5
RV5
or RC5-1
or RT5
1
+
RV5
or RT5
–
1SBC101412S0201
AS09..S ... AS16..S
AS09..S ... AS16..S
AS09..S … AS16..S
ASL09..S ... ASL16..S
ASL09..S ... ASL16..S
ASL09..S … ASL16..S
6/8 | ABB
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Main accessories
1SBC101037F0014
Front-mounted instantaneous auxiliary contact blocks
For contactors
CA3-10S
Auxiliary Type
contacts
Order code
Pkg
qty
Weight
(1 pce)
CA3-10S
CA3-01S
1SBN011019T1010
1SBN011019T1001
10
10
kg
0.011
0.011
For contactors
Type
Order code
Pkg
qty
AS09..S … AS16..S, ASL09..S … ASL16..S
VM3
1SBN031005T1000
10
1
0
1SBC101069F0014
AS09..S … AS16..S
ASL09..S … ASL16..S
0
1
Mechanical interlock unit
VM3
Weight
(1 pce)
kg
0.002
6
1SBC574001F0301
Surge suppressors
For contactors
AS09..S ... AS16..S,
ASL09..S ... ASL16..S
RV5
AS09..S ... AS16..S
AC
●
●
●
●
●
●
●
●
–
–
–
–
–
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
Order code
Pkg
qty
Weight
(1 pce)
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
Order code
Pkg
qty
1SBN081020R1000
1
Connecting links with manual motor starters
For contactors
Manual motor
starter
Type
AS09..S ... AS16..S
ASL09..S ... ASL16..S
MS116-0.16 ... MS116-16 BEA16-3U
MS132-0.16 ... MS132-16
Weight
(1 pce)
kg
0.045
1SBC101412S0201
BEA16-3U
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
Type
1SBC101384F0010
ASL09..S ... ASL16..S
Rated control circuit
voltage - Uc
ABB | 6/9
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
AS09..S
AS12..S
ASL09..S
ASL12..S
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50 / 60 Hz
AS16..S
ASL16..S
20 A
2.5 mm²
22 A
2.5 mm²
22 A
2.5 mm²
20 A
15 A
12 A
2.5 mm²
22 A
17 A
14 A
22 A
17 A
14 A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
9 A
9 A
9 A
8 A
8 A
5 A
12 A
12 A
12 A
11 A
11 A
7 A
15.7 A
15.5 A
15.5 A
13.6 A
12.5 A
9 A
220-230-240 V
400 V
415 V
440 V
500 V
690 V
2.2 kW
3 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
4 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
7.5 kW
12 A
5.5 kW
16 A
7.5 kW
22 A
11 kW
250 A
124 A
75 A
55 A
22 A
250 A
124 A
75 A
55 A
22 A
1.1 W
0.33 W
1.1 W
0.55 W
AC operated
DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
Ue max. ≤ 690 V, 50/60 Hz
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a
Rated operational power AC-8a
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,
in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
Power dissipation per pole
Max. electrical switching frequency
25 A
230 A
100 A
65 A
1 min 50 A
15 min 20 A
1 s
10 s
30 s
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-4
155 A
90 A
0.9 W
0.18 W
600 cycles/h
1200 cycles/h
300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101490S0201
6
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
6/10 | ABB
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
AC operated
DC operated
Standards
Max. operational voltage
NEMA size
Thermal current
NEMA continuous amp rating
115 V AC
NEMA maximum horse power ratings 1-phase, 60 Hz
NEMA maximum horse power ratings 3-phase, 60 Hz
UL / CSA General use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
230 V AC
200 V AC
230 V AC
460 V AC
575 V AC
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
AS09..S
ASL09..S
UL 508, CSA C22.2 N°14
690 V
00
9 A
1/3 hp
1 hp
1-1/2 hp
1-1/2 hp
2 hp
2 hp
AS12..S
ASL12..S
AS16..S
ASL16..S
00
00
1/3 hp
1 hp
1-1/2 hp
1-1/2 hp
2 hp
2 hp
1/3 hp
1 hp
1-1/2 hp
1-1/2 hp
2 hp
2 hp
12 A
AWG 14
12 A
AWG 14
15.2 A
AWG 12
7.2 A
8 A
1/3 hp
1 hp
9.8 A
10 A
1/2 hp
1-1/2 hp
13.8 A
12 A
3/4 hp
2 hp
7.8 A
6.8 A
7.6 A
9 A
2 hp
2 hp
5 hp
7-1/2 hp
7.8 A
9.6 A
11 A
11 A
2 hp
3 hp
7-1/2 hp
10 hp
11 A
15.2 A
14 A
11 A
3 hp
5 hp
10 hp
10 hp
40 A
J
50 A
60 A
6
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
For general use
For motor use
600 cycles/h
1200 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor
Operation
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
B2
C2
Vibration withstand acc. to IEC 60068-2-6
AS09..S
ASL09..S
AS12..S
ASL12..S
AS16..S
ASL16..S
690 V
600 V
6 kV
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
10 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
Shock direction
A
B1
B2
C1
C2
AS contactors - AC operated
ASL contactors - DC operated
20 g
20 g
10 g closed position / 5 g open position
15 g
15 g
10 g
20 g closed position / 9 g open position
15 g
20 g closed position / 14 g open position
14 g
5...300 Hz / 3 g closed position / 2 g open position
closed position / 10 g open position
closed position / 5 g open position
closed position / 8 g open position
closed position / 8 g open position
ABB | 6/11
1SBC101490S0201
Contactor types
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Magnet system characteristics for AS09..S … AS16..S contactors
Contactor types
Coil operating limits
AC operated
AS09..S
AS12..S
AS16..S
AC supply
acc. to IEC 60947-4-1
AC control voltage Rated control circuit voltage Uc
at 50 Hz
at 60 Hz
Coil consumption Average pull-in value 50 Hz
60 Hz
50/60 Hz
Average holding value 50 Hz
60 Hz
50/60 Hz
Drop-out voltage
Operating time
Between coil energization and:
Between coil de-energization and:
6
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
24...415 V
24...415 V
33 VA
33 VA
33 VA
6.5 VA / 1.5 W
5 VA / 1.2 W
6.5 VA / 1.5 W
Approx. 30...50 % of Uc
9...24 ms
6...18 ms
5...19 ms
7...22 ms
(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.
Magnet system characteristics for ASL09..S … ASL16..S contactors
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
DC control voltage
Drop-out voltage
Coil time constant
DC operated
ASL09..S
ASL12..S
ASL16..S
DC supply
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
Rated control circuit voltage Uc
12...240 V DC
Average pull-in value 3 W
Coil consumption
Average holding value 3 W
Approx. 10...40 % of Uc
L/R 12 ms
Open
L/R 40 ms
Closed
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
36...59 ms
31...53 ms
13...17 ms
15...20 ms
(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2
Mounting characteristics and conditions for use
Contactor types
AC operated
DC operated
AS09..S
ASL09..S
Mounting positions
AS12..S
ASL12..S
Pos. 2
+30°
AS16..S
ASL16..S
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 5
The contactors can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101490S0201
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 1 ± 30°
6/12 | ABB
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Connecting characteristics
Contactor types
AC operated
DC operated
AS09..S
ASL09..S
AS12..S
ASL12..S
AS16..S
ASL16..S
Main terminals
Spring terminals
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...12
10 mm
1x
2x
1x
2x
1x
2x
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...14
10 mm
6
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
IP20
Flat Ø 3.5
1SBC101490S0201
All terminals
Screwdriver type
ABB | 6/13
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Technical data
Built-in auxiliary contacts according to IEC
Contactor types
AC operated
DC operated
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free air thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
6
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
AC-15
DC-13
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
Mirror contacts
acc. to annex F of IEC 60947-4-1
AS09..S
ASL09..S
690 V
50 / 60 Hz
10 A
AS12..S
ASL12..S
AS16..S
ASL16..S
6 A
4 A
3 A
2 A
2 A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
10 A
100 A
140 A
12 V / 3 m
10-7
1.5 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3 aux.
contact blocks) are mechanically linked contacts.
Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA3 aux. contact blocks) are
mirror contacts.
Built-in auxiliary contacts according to UL / CSA
Contactor types
AS09..S
ASL09..S
600 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
AS12..S
ASL12..S
AS16..S
ASL16..S
1SBC101490S0201
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
AC operated
DC operated
6/14 | ABB
Notes
1SBC101490S0201
6
ABB | 6/15
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Electrical durability
AS
L0
A
9.
AS S12
.S
16 ..S
..S , A
, A SL
SL 12
16 ..S
..S ,
AS
09
..S
Millions of
operating
cycles
A
AS SL0
16 9.
..S .S,
, A AS
SL 12
16 ..S
..S , A
S
L1
2.
.S
,
Electrical durability for AC-1 utilization category - Ue ≤ 690 V
Note: AC-1 maximum current is selected according to ambient temperature. Please see technical data.
Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of
the load. Maximum electrical switching frequency: 600 cycles / hour.
4
3
2
6
1 3 5 7 9
1
0.6
0.5
0.3
0.2
9
7
5
3
1
9
7
9
7
5
3
1
5
3
0.1
1 3 5 7 9
1
2
3
5
9 10
20
30
Breaking current Ic (A)
1SBC101946S0201
Example:
Breaking current = 9 A.
On the opposite curve at intersection " " 9 A the corresponding value for the electrical durability is approximately 0.6 millions
operating cycles.
6/16 | ABB
AS09..S ... AS16..S and
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Electrical durability
AS
Millions of
operating
cycles
09
AS ..S
12 , A
..S SL
, A 09
AS
S ..S
16
..S L12
..S
,A
SL
16
..S
Electrical durability for AC-3 utilization category - Ue ≤ 440 V - Ambient temperature ≤ 60 °C
Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current). Maximum electrical switching frequency: 1200 cycles / hour.
10
5
3
9
7
5
3
1
2
6
9
7
5
3
1
1
0.5
0.3
0.2
1
2
3
4
5
10
3
5
7
9
20
Breaking current Ic (A)
1SBC101945S0201
Example:
Breaking current = 4 A.
On the opposite curve at intersection " " 4 A the corresponding value for the electrical durability is approximately 3 millions
operating cycles.
ABB | 6/17
AS09..S ... AS16..S 3-pole contactors - with spring terminals
Terminal marking and positioning
AS..S contactors - AC operated
Standard devices without addition of auxiliary contacts
1L1 3L2 5L3 13
1L1 3L2 5L3 21
A1
NO
NC
NO
NC
2T1 4T2 6T3 14
2T1 4T2 6T3 22
A2
AS09 ... AS16-30-10S
1L1 3L2 5L3 13
A1
A1
1L1
3L2
5L3
13
NO
A2
2T1
4T2
6T3
NO
14
A2
AS09 ... AS16-30-01S
AS09 ... AS16-30-10S
A1
1L1
3L2
5L3
21
NC
A2
2T1
4T2
6T3
NC
22
AS09 ... AS16-30-01S
A1
NO
21NC 31NC 43NO 53NO
NC NC NO NO
22NC 32NC 44NO 54NO
NO
2T1 4T2 6T3 14
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
NO
54
A2
AS09 … AS16-30-32S
AS09 ... AS16-30-32S
Other possible contact combinations with auxiliary contact blocks added by the user
1L1 3L2 5L3 13
1L1 3L2 5L3 13
A1
NO
A1
NO
21
2-
-1
=
NC
22
+
2-
-2
NO
2T1 4T2 6T3 14
2T1 4T2 6T3 14
A2
=
21
33
NO
22
34
1L1 3L2 5L3 13
A1
+
3L2
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
CA3-01S
Combination 11
A1
NO
2-
3-
-1
=
+
2-
NO
2T1 4T2 6T3 14
1L1
A2
AS09 ... AS16-30-10S
NO
NC
A1
NO
Combination 11
1L1 3L2 5L3 13
NC
3-
NC
-3
+
-2
NO
-4
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
NO
2T1 4T2 6T3 14
A2
Combination 21
=
A2
AS09 ... AS16-30-10S
+
CA3-01S
+
CA3-10S
Combination 21
CA3..S 1-pole auxiliary contact blocks
-1
-3
-3
NO
-1
NO
NC
-4
NC
-2
-4
CA3-10S
6/18 | ABB
-2
CA3-01S
1SBC101413S0201
6
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Terminal marking and positioning
ASL..S contactors - DC operated (the polarity A1+, A2- must be respected)
Standard devices without addition of auxiliary contacts
1L1 3L2 5L3 13
1L1 3L2 5L3 21
A1+
NO
NC
NO
NC
2T1 4T2 6T3 14
A1+
2T1 4T2 6T3 22
A2-
ASL09 ... ASL16-30-10S
A1+
1L1
3L2
5L3
13
NO
A2-
2T1
4T2
6T3
NO
14
A2-
ASL09 ... ASL16-30-01S
ASL09 ... ASL16-30-10S
A1+
1L1
3L2
5L3
21
NC
A2-
2T1
4T2
6T3
NC
22
ASL09 ... ASL16-30-01S
1L1 3L2 5L3 13 A1+
NO
21NC 31NC 43NO 53NO
NC NC NO NO
22NC 32NC 44NO 54NO
NO
2T1 4T2 6T3 14
A1+
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
A2-
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
NO
54
A2-
ASL09 … ASL16-30-32
6
ASL09 ... ASL16-30-32S
Other possible contact combinations with auxiliary contact blocks added by the user
1L1 3L2 5L3 13
1L1 3L2 5L3 13
A1+
NO
A1+
NO
21
2-
-1
=
NC
22
+
2-
-2
NO
2T1 4T2 6T3 14
=
21
33
NO
22
34
A2-
ASL09 ... ASL16-30-10S + CA3-01S
1L1 3L2 5L3 13
A1+
NO
NC
1L1
3L2
5L3
13
NO
21
NC
A2-
2T1
4T2
6T3
NO
14
NC
22
Combination 11
A1+
NO
2-
3-
-1
=
+
2-
NO
2T1 4T2 6T3 14
A1+
NO
2T1 4T2 6T3 14
A2-
Combination 11
1L1 3L2 5L3 13
NC
3-
NC
-2
-3
+
NO
-4
A1+
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2-
2T1
4T2
6T3
NO
14
NC
22
NO
34
NO
2T1 4T2 6T3 14
A2-
Combination 21
=
A2-
ASL09 ... ASL16-30-10S + CA3-01S + CA3-10S
Combination 21
CA3..S 1-pole auxiliary contact blocks
-1
NO
-1
NO
NC
-4
-2
-4
CA3-10S
NC
1SBC101413S0201
-3
-3
-2
CA3-01S
ABB | 6/19
AS09..S ... AS16..S 3-pole contactors - with spring terminals
Main dimensions
mm, inches
72.5 2.85"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
50 1.97"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
60 2.36"
45 1.77"
AS09..S, AS12..S, AS16..S
110.8 4.36"
10 0.39"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
35 1.38"
ø 4.2 0.17"
50 1.97"
45 1.77"
60 2.36"
6
72.5 2.85"
AS09..S, AS12..S, AS16..S
+ CA3..S front-mounted 1-pole auxiliary contact block
110.8 4.36"
10 0.39"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
50 1.97"
2x
M4 8-32 UNC
7 0.28"
60 2.36"
72.5 2.85"
45 1.77"
AS09...16-30-32S
6/20 | ABB
1SBC101414S0201
AS09..S, AS12..S, AS16..S
+ VM3 mechanical interlock unit including two BB3 fixing clips
80 3.15"
ø 4.2 0.17"
50 1.97"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
4x
M4 8-32 UNC
60 2.36"
72.5 2.85"
7 0.28"
10 0.39"
90 3.54"
ASL09..S ... ASL16..S 3-pole contactors - with spring terminals
Main dimensions
mm, inches
72.5 2.85"
45 1.77"
2x
M4 8-32 UNC
10 0.39"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
60 2.36"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
ASL09..S, ASL12..S, ASL16..S
110.8 4.36"
10 0.39"
72.5 2.85"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
6
35 1.38"
ø 4.2 0.17"
60 2.36"
45 1.77"
ASL09..S, ASL12..S, ASL16..S
+ CA3..S front-mounted 1-pole auxiliary contact block
110.8 4.36"
72.5 2.85"
10 0.39"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
7 0.28"
35 1.38"
ø 4.2 0.17"
60 2.36"
45 1.77"
ASL09...16-30-32S
72.5 2.85"
4x
M4 8-32 UNC
5.5 0.22"
80 3.15"
ø 4.2 0.17"
1SBC101414S0201
35 mm EN/IEC 60715
68 2.68"
10 0.39"
60 2.36"
7 0.28"
90 3.54"
ASL09..S, ASL12..S, ASL16..S
+ VM3 mechanical interlock unit including two BB3 fixing clips
ABB | 6/21
NS..S contactor relays - with spring terminals
AC operated
1SBC101015F0014
Description
NS22ES
6
NS..S contactor relays are used for switching auxiliary and control circuits.
These contactor relays are designed with:
–– spring terminals
–– 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: AC operated
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
Ordering details
Number of contacts
1st stack
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
Rated control circuit
voltage
Uc
(1)
2nd stack
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
V 50 Hz
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
24
230
400
V 60 Hz
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
24
120
230
400
Type
NS22ES-20
NS22ES-16
NS22ES-26
NS22ES-28
NS31ES-20
NS31ES-16
NS31ES-26
NS31ES-28
NS40ES-20
NS40ES-16
NS40ES-26
NS40ES-28
NS44ES-20
NS44ES-16
NS44ES-26
NS44ES-28
NS53ES-20
NS53ES-16
NS53ES-26
NS53ES-28
NS62ES-20
NS62ES-16
NS62ES-26
NS62ES-28
NS71ES-20
NS71ES-16
NS71ES-26
NS71ES-28
NS80ES-20
NS80ES-16
NS80ES-26
NS80ES-28
Order code
Weight
1SBH101004R2022
1SBH101004R1622
1SBH101004R2622
1SBH101004R2822
1SBH101004R2031
1SBH101004R1631
1SBH101004R2631
1SBH101004R2831
1SBH101004R2040
1SBH101004R1640
1SBH101004R2640
1SBH101004R2840
1SBH101004R2044
1SBH101004R1644
1SBH101004R2644
1SBH101004R2844
1SBH101004R2053
1SBH101004R1653
1SBH101004R2653
1SBH101004R2853
1SBH101004R2062
1SBH101004R1662
1SBH101004R2662
1SBH101004R2862
1SBH101004R2071
1SBH101004R1671
1SBH101004R2671
1SBH101004R2871
1SBH101004R2080
1SBH101004R1680
1SBH101004R2680
1SBH101004R2880
Pkg
(1 pce)
kg
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.220
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
0.260
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
110.8 4.36"
72.5 2.85"
6/22 | ABB
35 mm EN/IEC 60715
7 0.28"
5.5 0.22"
NS44ES, NS53ES, NS62ES, NS71ES, NS80ES
1SBC101481S0201
NS22ES, NS31ES, NS40ES
68 2.68"
5.5 0.22"
72.5 2.85"
45 1.77"
7 0.28"
35 mm EN/IEC 60715
68 2.68"
45 1.77"
35.4 1.39"
Main dimensions
NSL..S contactor relays - with spring terminals
DC operated
1SBC101021F0014
Description
NSL..S contactor relays are used for switching auxiliary and control circuits.
These contactor relays are designed with:
–– spring terminals
–– 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: low coil consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable
for direct control by PLC outputs (the polarity on the coil terminals A1+ and A2- must be respected)
–– add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories.
Ordering details
Number of contacts
1st stack
Rated control circuit
voltage
2nd stack
Type
Order code
Weight
1SBH103004R8122
1SBH103004R8322
1SBH103004R8622
1SBH103004R8822
1SBH103004R8131
1SBH103004R8331
1SBH103004R8631
1SBH103004R8831
1SBH103004R8140
1SBH103004R8340
1SBH103004R8640
1SBH103004R8840
1SBH103004R8144
1SBH103004R8344
1SBH103004R8644
1SBH103004R8844
1SBH103004R8153
1SBH103004R8353
1SBH103004R8653
1SBH103004R8853
1SBH103004R8162
1SBH103004R8362
1SBH103004R8662
1SBH103004R8862
1SBH103004R8171
1SBH103004R8371
1SBH103004R8671
1SBH103004R8871
1SBH103004R8180
1SBH103004R8380
1SBH103004R8680
1SBH103004R8880
Pkg
(1 pce)
kg
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.280
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
0.320
Uc
(1)
A1+
13
NO
21
NC
31
NC
43
NO
NO
14
NC
22
NC
32
NO
44
13
NO
21
NC
33
NO
43
NO
NO
14
NC
22
NO
34
NO
44
13
NO
23
NO
33
NO
43
NO
NO
14
NO
24
NO
34
NO
44
A1+
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
A2-
A1+
A2-
A1+
A2-
V DC
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
24
48
110
220
NSL22ES-81
NSL22ES-83
NSL22ES-86
NSL22ES-88
NSL31ES-81
NSL31ES-83
NSL31ES-86
NSL31ES-88
NSL40ES-81
NSL40ES-83
NSL40ES-86
NSL40ES-88
NSL44ES-81
NSL44ES-83
NSL44ES-86
NSL44ES-88
NSL53ES-81
NSL53ES-83
NSL53ES-86
NSL53ES-88
NSL62ES-81
NSL62ES-83
NSL62ES-86
NSL62ES-88
NSL71ES-81
NSL71ES-83
NSL71ES-86
NSL71ES-88
NSL80ES-81
NSL80ES-83
NSL80ES-86
NSL80ES-88
6
Note: for multiple packaging, please contact your ABB local sales organization.
(1) Other control voltages see voltage code table.
mm, inches
110.8 4.36"
72.5 2.85"
5.5 0.22"
1SBC101482S0201
NSL22ES, NSL31ES, NSL40ES
7 0.28"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
5.5 0.22"
72.5 2.85"
45 1.77"
35 mm EN/IEC 60715
45 1.77"
35.4 1.39"
Main dimensions
68 2.68"
NSL22ES
NSL44ES, NSL53ES, NSL62ES, NSL71ES, NSL80ES
ABB | 6/23
NS..S and NSL..S contactor relays - with spring terminals
Main accessories
Contactor relays and main accessories
4-pole contactor relay
RV5, RC5-1 or RT5
NS..S
NSL..S
Contactor relays
8-pole contactor relay
CA3..S
RV5, RC5-1 or RT5
6
NS..S
NSL..S
Contactor relays
Main accessory fitting details
Contactor
types
Front-mounted accessories
Auxiliary contact blocks
Main
poles
Side-mounted accessories
1-pole CA3..S
2
3
4
4
5
6
7
8
2
3
4
4
5
6
7
8
2
1
0
4
3
2
1
0
2
1
0
4
3
2
1
0
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
2 max.
Surge suppressors
+
–
2 max.
–
+
RV5
or
RC5-1
RV5
or
RC5-1
RV5
or
RT5
RV5
or
RT5
1SBC101415S0201
NS..S
NS..S
NS..S
NS..S
NS..S
NS..S
NS..S
NS..S
NSL..S
NSL..S
NSL..S
NSL..S
NSL..S
NSL..S
NSL..S
NSL..S
6/24 | ABB
NS..S and NSL..S contactor relays - with spring terminals
Main accessories
Front mounted instantaneous auxiliary contact blocks
Auxiliary Type
contacts
NS..S, NSL..S
1SBC574001F0301
CA3-10S
1
0
0
1
Order code
Pkg
qty
Weight
(1 pce)
CA3-10S
CA3-01S
1SBN011019T1010
1SBN011019T1001
10
10
kg
0.011
0.011
Type
Order code
Pkg
qty
Surge suppressors
For contactor relays
Rated control circuit
voltage - Uc
Weight
(1 pce)
RV5
NS..S,
NSL..S
NS..S
NSL..S
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
AC
●
●
●
●
●
●
●
●
–
–
–
–
–
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
6
1SBC101415S0201
1SBC101037F0014
For contactor relays
ABB | 6/25
NS..S and NSL..S contactor relays - with spring terminals
Technical data
Contact utilization characteristics according to IEC
Contactor relay types
AC operated
DC operated
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
6
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
NS..S
NSL..S
IEC 60947-5-1 and EN 60947-5-1
690 V
50 / 60 Hz
10 A
6 A
4 A
3 A
2 A
2 A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
Short-circuit protection device for contactors
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,in free air from a cold state
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
Mechanically linked contacts
acc. to annex L of IEC 60947-5-1
10 A
100 A
140 A
12 V / 3 mA
10-7
1.5 ms
0.1 W
AC-15 1200 cycles/h
DC-13 900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3..S aux.
contact blocks) are mechanically linked contacts.
for 1.0 s
for 0.1 s
Contact utilization characteristics according to UL / CSA
Contactor relay types
NS..S
NSL..S
UL 508, CSA C22.2 N°14
600 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
1SBC101503S0201
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
AC operated
DC operated
6/26 | ABB
NS..S and NSL..S contactor relays - with spring terminals
Technical data
Magnet system characteristics for NS..S contactor relays
Contactor relay types
Coil operating limits
AC operated
acc. to IEC 60947-5-1
AC control voltage
NS..S
AC supply
Rated control circuit voltage Uc
at 50 Hz
at 60 Hz
Coil consumption Average pull-in value 50 Hz
60 Hz
50/60 Hz
Average holding value 50 Hz
60 Hz
50/60 Hz
Drop-out voltage
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
24...415 V
24...415 V
33 VA
33 VA
33 VA
6.5 VA / 1.5 W
5 VA / 1.2 W
6.5 VA / 1.5 W
Approx. 30...50 % of Uc
9...24 ms
6...18 ms
5...19 ms
7...22 ms
(1) The use of RC5-1 surge suppressor increases opening time by a factor of 2 to 3.
6
Magnet system characteristics for NSL..S contactor relays
Contactor relay types
Coil operating limits
DC operated
0.85...1.1 x Uc (at θ ≤ 60 °C); Uc (at θ ≤ 70 °C)
acc. to IEC 60947-5-1
DC control voltage
Rated control circuit voltage Uc
Coil consumption
Average pull-in value
Average holding value
Drop-out voltage
L/R
Coil time constant
Open
L/R
Closed
Operating time
N.O. contact closing
Between coil energization and:
Between coil de-energization and:
NSL..S
DC supply
N.C. contact opening
N.O. contact opening (1)
N.C. contact closing (1)
12...240 V DC
3 W
3 W
Approx. 10...40 % of Uc
12 ms
40 ms
36...59 ms
31...53 ms
13...17 ms
15...20 ms
(1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2.
Mounting characteristics and conditions for use
Contactor relay types
AC operated
DC operated
NS..S
NSL..S
Mounting positions
Pos. 2
Pos. 4
Pos. 3
Pos. 1
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
Pos. 5
The contactor relays can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101503S0201
ABB | 6/27
NS..S and NSL..S contactor relays - with spring terminals
Technical data
General technical data
Contactor relay types
AC operated
DC operated
Rated insulation voltage Ui
acc. to IEC 60947-5-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Ambient air temperature close to contactor relay
Operation in free air
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
690 V
600 V
6 kV
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
20 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
Shock direction
Mounting position 1
6
C1
A
A
B1
B2
C2
NS..S
NSL..S
A
B1
B2
C1
C2
Vibration withstand
acc. to IEC 60068-2-6
NS contactor relays - AC operated
20 g
5 g
15 g
19 g closed position / 8 g open position
16 g closed position / 13 g open position
5...300 Hz
3 g closed position / 2 g open position
NSL contactor relays - DC operated
20 g closed position / 10 g open position
15 g closed position / 5 g open position
10 g
19 g closed position / 8 g open position
14 g closed position / 8 g open position
Connecting characteristics
Contactor relay types
AC operated
DC operated
NS..S
NSL..S
Main terminals
Spring terminals
Connection capacity (min. ... max.)
Pole and coil terminals
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...14
10 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All terminals
IP20
Flat Ø 3.5
1SBC101503S0201
Screwdriver type
6/28 | ABB
Notes
1SBC101503S0201
6
ABB | 6/29
NS..S contactor relays - with spring terminals
Terminal marking and positioning
NS..S contactor relays - AC operated
Standard devices without addition of auxiliary contact blocks
13 21 31 43
13 21 33 43
A1
NO NC NC NO
13 23 33 43
A1
NO NC NO NO
13 23 33 43
A1
NO NO NO NO
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
NO NO NO NO
51 61 71 81
NS22ES
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
NS31ES
NC NC NC NC
52 62 72 82
NO NC NC NO
14 22 32 44
NO NC NO NO
14 22 34 44
A2
NS22ES
14 24 34 44
A2
NS31ES
13 23 33 43
14 24 34 44
A2
NS40ES
13 23 33 43
A1
NO NO NO NO
13 23 33 43
A1
NS44ES
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
53 61 71 81
53 61 71 83
53 61 73 83
53 63 73 83
NO NC NC NC
NO NC NC NO
NO NC NO NO
NO NO NO NO
54 62 72 82
54 62 72 84
54 62 74 84
54 64 74 84
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
14 24 34 44
14 24 34 44
A2
NS53ES
14 24 34 44
A2
NS62ES
14 24 34 44
A2
NS71ES
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
NS40ES
13 23 33 43
A1
A1
A2
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
NS44ES
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
NS53ES
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
A2
NS80ES
NS62ES
NS71ES
NS80ES
Other possible contact combinations with auxiliary contact blocks added by the user
13 21 33 43
13 21 33 43
A1
NO NC NO NO
13 23 33 43
A1
NO NC NO NO
53
NO NO NO NO
5-
=
NO
54
+
5-
NO NC NO NO
14 22 34 44
Combination 41E
13 23 33 43
14 22 34 44
=
51
61
NO
NC
NC
-4
52
62
14 24 34 44
A2
+
CA3-10S
53
=
NO
54
+
5-
NO NO NO NO
-3
53
63
NO
NO
NO
-4
54
64
NO NO NO NO
14 24 34 44
A2
Combination 50E
=
14 24 34 44
NS40ES
+
CA3-10S
5-
6-
-1
+
14 24 34 44
A2
=
-1
+
NC
NC
-2
A1
13
NO
21
NC
33
NO
43
NO
53
NO
A2
NO
14
NC
22
NO
34
NO
44
NO
54
Combination 41E
-2
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
A2
NS40ES
13 23 33 43
A1
+
CA3-01S
+
CA3-01S
A1
Combination 42E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO NO NO NO
5-
6-
5-
6-
-3
=
NO NO NO NO
A2
6-
NO NO NO NO
NO NO NO NO
5-
5-
=
Combination 42E
13 23 33 43
A1
NO NO NO NO
A1
NO NO NO NO
NO NO NO NO
NS31ES
13 23 33 43
A1
NO NO NO NO
14 24 34 44
-3
NO NC NO NO
A2
13 23 33 43
A1
+
NO
-3
+
NO
-4
-4
NO NO NO NO
14 24 34 44
A2
Combination 60E
=
NS40ES
Combination 50E
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
A2
+
CA3-10S
+
CA3-10S
Combination 60E
CA3..S 1-pole auxiliary contact blocks
-1
-3
-3
NO
-1
NO
NC
-4
NC
-2
-4
CA3-10S
6/30 | ABB
-2
CA3-01S
1SBC101416S0201
6
NO NO NO NO
NSL..S contactor relays - with spring terminals
Terminal marking and positioning
NSL..S contactor relays - DC operated (the polarity A1+, A2- must be respected)
Standard devices without addition of auxiliary contact blocks
A1+
13 21 31 43
13 21 33 43
A1+
NO NC NC NO
13 23 33 43
A1+
NO NC NO NO
13 23 33 43
A1+
NO NO NO NO
A1+
NO NO NO NO
A2-
51 61 71 81
13
NO
21
NC
31
NC
43
NO
NO
14
NC
22
NC
32
NO
44
A1+
A2-
NSL22ES
13
NO
21
NC
33
NO
43
NO
NO
14
NC
22
NO
34
NO
44
NSL31ES
NC NC NC NC
52 62 72 82
NO NC NC NO
14 22 32 44
NO NC NO NO
14 22 34 44
A2-
NO NO NO NO
14 24 34 44
A2-
A1+
NO NO NO NO
14 24 34 44
A2-
A2A2-
NSL22ES
NSL31ES
13 23 33 43
NSL40ES
13 23 33 43
A1+
NSL44ES
13 23 33 43
A1+
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
53 61 71 81
53 61 71 83
53 61 73 83
53 63 73 83
NO NC NC NC
NO NC NC NO
NO NC NO NO
NO NO NO NO
54 62 72 82
54 62 72 84
54 62 74 84
54 64 74 84
NO NO NO NO
NO NO NO NO
NO NO NO NO
NO NO NO NO
14 24 34 44
14 24 34 44
A2-
NSL53ES
14 24 34 44
A2-
NSL62ES
14 24 34 44
A2-
NSL71ES
23
NO
33
NO
43
NO
NO
14
NO
24
NO
34
NO
44
NSL40ES
13 23 33 43
A1+
13
NO
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
NSL80ES
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2-
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
NSL62ES
NSL53ES
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A2-
13
NO
NSL44ES
A1+
A1+
A1+
NSL71ES
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
6
NSL80ES
Other possible contact combinations with auxiliary contact blocks added by the user
13 21 33 43
13 21 33 43
A1+
NO NC NO NO
13 23 33 43
A1+
NO NC NO NO
53
NO NO NO NO
5-
=
NO
54
+
5-
NO NC NO NO
14 22 34 44
-3
51
61
NO
NC
NC
-4
52
62
NO NC NO NO
14 22 34 44
A2-
13 23 33 43
A1+
NO NO NO NO
14 24 34 44
5-
6-
5-
6-
-1
=
NO NO NO NO
A2-
A1+
+
NC
-1
+
NC
-2
14 24 34 44
13
NO
21
NC
33
NO
43
NO
53
NO
A2-
NO
14
NC
22
NO
34
NO
44
NO
54
Combination 41E
-2
A1+
NO NO NO NO
A2-
A1+
A2A2-
Combination 41E
13 23 33 43
=
NSL31ES
13 23 33 43
A1+
NO NO NO NO
+
=
54
+
5-
NO NO NO NO
-3
53
63
NO
NO
NO
-4
54
64
NO NO NO NO
14 24 34 44
A2-
Combination 50E
=
=
14 24 34 44
NSL40ES
+
CA3-10S
+
CA3-01S
+
CA3-01S
A1+
5-
6-
5-
6-
-3
=
+
NO
-3
+
NO
-4
14 24 34 44
Combination 60E
=
NSL40ES
CA3-10S
43
NO
51
NC
61
NC
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
13
NO
23
NO
33
NO
43
NO
53
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
Combination 50E
-4
A1+
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
A2-
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
A2-
+
33
NO
A1+
NO NO NO NO
A2-
23
NO
Combination 42E
NO NO NO NO
NO NO NO NO
A2-
NS4L0ES
13 23 33 43
A1+
NO NO NO NO
5-
NO
Combination 42E
13 23 33 43
A1+
NO NO NO NO
53
14 24 34 44
CA3-10S
13
NO
+
CA3-10S
Combination 60E
CA3..S 1-pole auxiliary contact blocks
-1
NO
NC
-4
NC
-2
-4
CA3-10S
1SBC101416S0201
-1
-3
-3
NO
-2
CA3-01S
ABB | 6/31
NS..S contactor relays - with spring terminals
Main dimensions mm, inches
4-pole contactor relays
72.5 2.85"
5.5 0.22"
60 2.36"
35 mm EN/IEC 60715
68 2.68"
2x
M4 8-32 UNC
7 0.28"
35 1.38"
ø 4.2 0.17"
50 1.97"
45 1.77"
NS22ES, NS31ES, NS40ES
110.8 4.36"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
35 1.38"
ø 4.2 0.17"
50 1.97"
45 1.77"
60 2.36"
6
72.5 2.85"
NS22ES, NS31ES, NS40ES
+ CA3..S front-mounted 1-pole auxiliary contact block
8-pole contactor relays
110.8 4.36"
72.5 2.85"
35.4 1.39"
35 mm EN/IEC 60715
68 2.68"
5.5 0.22"
35 1.38"
ø 4.2 0.17"
50 1.97"
2x
M4 8-32 UNC
7 0.28"
60 2.36"
45 1.77"
1SBC101417S0201
NS44ES, NS53ES, NS62ES, NS71ES, NS80ES
6/32 | ABB
NSL..S contactor relays - with spring terminals
Main dimensions mm, inches
4-pole contactor relays
72.5 2.85"
45 1.77"
35 mm EN/IEC 60715
5.5 0.22"
35 1.38"
ø 4.2 0.17"
60 2.36"
68 2.68"
2x
M4 8-32 UNC
7 0.28"
NSL22ES, NSL31ES, NSL40ES
110.8 4.36"
72.5 2.85"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
68 2.68"
35 mm EN/IEC 60715
7 0.28"
6
35 1.38"
ø 4.2 0.17"
60 2.36"
45 1.77"
NSL22ES, NSL31ES, NSL40ES
+ CA3..S front-mounted 1-pole auxiliary contact block
8-pole contactor relays
110.8 4.36"
72.5 2.85"
2x
M4 8-32 UNC
5.5 0.22"
35.4 1.39"
35 mm EN/IEC 60715
35 1.38"
ø 4.2 0.17"
NSL44ES, NSL53ES, NSL62ES, NSL71ES, NSL80ES
1SBC101417S0201
68 2.68"
7 0.28"
60 2.36"
45 1.77"
ABB | 6/33
Auxiliary contact blocks - with spring terminals
Accessories
1SBC101037F0014
Description
CA3-10S
The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits.
CA3 1-pole auxiliary contact blocks, designed for standard industrial environments, are equipped with:
– – N.O. or N.C. contacts.
– – spring-type connecting terminals.
All 1-pole auxiliary contact blocks are protected against accidental direct contact and bear the
corresponding function marking.
A maximum of two 1-pole auxiliary contact blocks can be front-mounted on 1-stack contactors or 1-stack
contactor relays.
Ordering details
For contactors
For contactor relays
Contact Type
blocks
Order code
Pkg
qty
Weight
(1 pce)
kg
1-pole auxiliary contact blocks with spring terminals
AS09..S ... AS16..S
NS..S, NSL..S
1 – CA3-10S
ASL09..S ... ASL16..S
– 1 CA3-01S
6
Main dimensions
1SBN011019T1010
1SBN011019T1001
10
10
0.011
0.011
mm, inches
110.8 4.36"
5.5 0.22"
10
0.39"
1SBC101497S0201
35 mm EN/IEC 60715
68 2.68"
6/34 | ABB
7 0.28"
35.4 1.39"
72.5 2.85"
45 1.77"
Auxiliary contact blocks - with spring terminals
Front mounting
Technical data
1-pole CA3..S
Types
Contact utilization characteristics according to IEC
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
690 V
10 A
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
acc. to IEC 60947-5-1
Making capacity
Breaking capacity
Ie / Rated operational current DC-13
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
10 A
for 1.0 s 100 A
for 0.1 s 140 A
12 V / 3 mA
10-7
0.1 W
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
Mechanically linked contact
6 A
4 A
3 A
2 A
2 A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
acc. to annex L of IEC 60947-5-1
Mirror contacts acc. to annex F of IEC 60947-4-1
6
10 millions operating cycles
3600 cycles/h
AC-15 1200 cycles/h
AC-13 900 cycles/h
Additional N.O. or N.C. auxiliary contacts (CA3..S aux. contact blocks) are mechanically linked
contacts
Additional N.C. auxiliary contacts (CA3..S aux. contact blocks) are mirror contacts
Contact utilization characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
690 V AC, 250 V DC
A600, Q300
10 A
7200 VA
720 VA
2.5 A
69 VA
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Connecting characteristics
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
1 or 2 x
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18…14
10 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
IP20
Screw terminals
All terminals
Screwdriver type
Spring terminals
Flat Ø 3.5
1SBC101498S0201
Connection capacity (min. ... max.)
Rigid solid
ABB | 6/35
Auxiliary contact blocks for AS09..S ... AS16..S, ASL09..S ... ASL16..S
contactors and NS, NSL contactor relays - with spring terminals
Electrical durability
Electrical durability for AC-15 utilization category - Ue ≤ 400 V
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
This curve represents the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.
The curve has been drawn for resistive and inductive loads up to 400 V:
– – AS09..S ... AS16..S and ASL09..S ... ASL16..S contactor built-in auxiliary contacts
–– 1-pole CA3..S
–– NS..S and NSL..S contactor relays.
Millions of
operating
cycles
30
20
10
5
3
2
1
0.5
0.3
0.2
1
0.1
0.02
0.05
0.1
0.2
0.3
0.5
1
3
1.3
5
7
9
2
3
4
5
6
10
Breaking current Ic (A)
Example:
Breaking current = 1.3 A
On the opposite curve at intersection " " 1.3 A the corresponding value for the electrical durability is approximately 2 millions
operating cycles.
1SBC101947S0201
6
6/36 | ABB
Notes
N12
6
ABB | 6/37
Surge suppressors for contactor coils
Accessories
Description
(V)
1000
T (µs)
0
100
1000
0
100
The operation of inductive circuits causes overvoltages, in particular on opening the contactor coil.
The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form
of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are
observed ranging from interference on the electronic devices to the breakdown of insulators and even the
destruction of certain sensitive components.
The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42 V /
50 Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.
Following a burst of discharges with a very steep slope, a damped oscillation emerges with a peak value
of 3500 V.
Overvoltage Factor
The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak
value Ûc of the coil rated control voltage Uc:
1SBC101042F0014
Ûs max.
k =
Ûc
k =
3500
≈ 60
42 √2
To reduce the harmful effects of these overvoltages, ABB has developed a range of surge suppressors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping
voltage frequencies.
Each case is different, but the technical data tolerances and generous sizing of parts have enabled us to
reduce the number of variants.
We have chosen the following solutions: transil diodes, varistors and RC blocks.
Note: A varistor is a resistor whose value decreases to a very large extent when a certain voltage is applied at its terminals.
1SBC101042F0014
RV5
Ordering details
For
contactors
For
contactor
relays
AS..S,
ASL..S
NS..S,
NSL..S
AS..S
NS..S
ASL..S
NSL..S
Rated control circuit
voltage - Uc
V
24...50
50...133
110...250
250...440
24...50
50...133
110...250
250...440
12...32
25...65
50...90
77...150
150...264
RT5
Main dimensions
AC
●
●
●
●
●
●
●
●
–
–
–
–
–
Order code
Pkg
qty
Weight
(1 pce)
RV5/50
RV5/133
RV5/250
RV5/440
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
1SBN050010R1000
1SBN050010R1001
1SBN050010R1002
1SBN050010R1003
1SBN050100R1000
1SBN050100R1001
1SBN050100R1002
1SBN050100R1003
1SBN050020R1000
1SBN050020R1001
1SBN050020R1002
1SBN050020R1003
1SBN050020R1004
2
2
2
2
2
2
2
2
2
2
2
2
2
kg
0.015
0.015
0.015
0.015
0.012
0.012
0.012
0.012
0.015
0.015
0.015
0.015
0.015
mm, inches
45 1.77"
68 2.68"
72.5 2.85"45 1.77"
68 2.68"
72.5 2.85"
DC
●
●
●
●
–
–
–
–
●
●
●
●
●
Type
45 1.77"
Easy connection to the coil terminals
(parallel mounting)
Clip-on for both fixing and connection.
No additional space
Clipped onto the right side part of
the contactor base without changing
contactor overall dimensions and
keeping a free access to coil terminals.
1SBC101499S0201
1SBC101042F0014
RC5-1
6/38 | ABB
Ûs max.
in AC k =
Uc √2
For example the following is obtained for the above graph:
68 2.68"
6
Ûs max.
in DC k =
Uc
Surge suppressors for contactor coils
Technical data
Varistor
RV5/50
RV5/133
RV5/250
RV5/440
24...50 V AC
50...133 V AC
110...250 V AC
250...440 V AC
24...50 V DC
50...133 V DC
110...250 V DC
250...440 V DC
132 V AC
270 V AC
480 V AC
825 V AC
132 V DC
270 V DC
480 V DC
825 V DC
none
-20...+70 °C
High energy absorption: good damping - Unpolarized system.
Clipping as from Uvdr*, thus voltage front up to this point.
*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10 %.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Advantages
Drawback
RC type
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
24...50 V AC
50...133 V AC
110...250 V AC
250...440 V AC
2 to 3 x Uc max.
2...3
-20...+70 °C
Very fast clipping - Attenuation of steep fronts and thus of high frequencies.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Advantages
Transil diode
RT5/32
RT5/65
RT5/90
RT5/150
12...32 V DC
25...65 V DC
50...90 V DC
77...150 V DC
50 V DC
100 V DC
150 V DC
210 V DC
1.1...1.2
-20...+70 °C
Good energy absorption - Unpolarized system - Simple, reliable system.
Delay on drop out which does not however reduce contactor breaking capacity.
Rated control circuit voltage Uc
Residual overvoltage (clipping voltage)
Opening time growth factor
Operating temperature
Advantages
Drawback
6
RT5/264
150...264 V DC
390 V DC
Wiring diagrams
RC type
E0734D
A2
A2
Transil diode
1SBC101602S0201
Varistor
E0735D
A2
A1
A1
E0733D
A1
ABB | 6/39
Connecting links for starting solutions and other accessories
Connecting links
1SBC101384F0010
The BEA16-3U insulated connecting links are used to connect an AS..S AC operated contactor or an
ASL..S DC operated contactor with a manual motor starter.
The connecting link ensure the electrical and mechanical connection between the contactor and the
manual motor starter.
BEA16-3U
Manual motor
starter
Type
AS09..S ... AS16..S
ASL09..S ... ASL16..S
MS116-0.16 ... MS116-16 BEA16-3U
MS132-0.16 ... MS132-16
Order code
Pkg
qty
1SBN081020R1000
1
Weight
(1 pce)
kg
0.045
BDT4 test block is suitable for switching on contactor off-load.
Marking on the block indicates the contactor type to fit with.
Ordering details
1SNC160101F0014
BDT4
BA4
For contactors
Test block
1SBC100043V0014
For contactors
Type
Order code
Pkg
qty
AS..S, ASL..S, NS..S, NSL..S
BDT4
1SBN110122T1000
10
Weight
(1 pce)
kg
0.007
Function markers
Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500
marking table to identify your contactors, overload relays or manual motor starters.
Marker dimensions: 7 x 20 mm (.276" x .787").
Ordering details
For contactors
Type
Order code
Pkg
qty
AS..S, ASL..S, NS..S, NSL..S
AMS 500 support plate for 8 BA4
HTP500 support plate
BA4
SPRC 1
HTP500-BA4
1SNA235156R2700
1SNA360010R1500
1SNA235712R2400
16
1
1
Weight
(1 pce)
kg
0.011
0.220
0.290
1SBC101782S0201
6
Ordering details
6/40 | ABB
Voltage code table
The below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please
give either type or order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the
type or in the order code according to the table below. Example: for contactor AS09-30-10S and coil 42 V 50/60 Hz, type is
AS09-30-10S-21 and order code is 1SBL101004R2110.
3-pole contactors - with spring terminals
Type
Order code
AS16 - 30 - 10 S - 26
1SBL121004R 26 10
N.O. N.C.
Main contacts
Contactor with spring terminal
AS
ASL
Contactor type
AC operated
DC operated
Contactor relays - with spring terminals
Contactor with spring terminal
Type
NS 40 E
S - 26
N.O. N.C.
Number contacts
NS
NSL
Contactor type
AC operated
DC operated
Order code
1SBH101004R 26 40
AC coil code
50 Hz
60 Hz
20 24 V
24 V
21 42 V
42 V
22 48 V
48 V
23 110 V
110 V
24 115 V
115 V
16 –
120 V
25 220 V
220 V
26 230 V
230 V
27 240 V
240 V
17 –
277 V
13 380 V
–
28 400 V
400 V
29 415 V
415 V
AC coil code
50 Hz
60 Hz
20 24 V
24 V
21 42 V
42 V
22 48 V
48 V
23 110 V
110 V
24 115 V
115 V
16 –
120 V
25 220 V
220 V
26 230 V
230 V
27 240 V
240 V
17 –
277 V
13 380 V
–
28 400 V
400 V
29 415 V
415 V
80
81
83
84
86
87
88
89
DC coil code
12 V
24 V
48 V
60 V
110 V
125 V
220 V
240 V
6
80
81
83
84
86
87
88
89
DC coil code
12 V
24 V
48 V
60 V
110 V
125 V
220 V
240 V
1SBC101621S0201 - Rev. A
Auxiliary contacts
N.O. N.C.
ABB | 6/41
Summary_6-2
6
6/42 | ABB
AF..S 3-pole contactors and
NF..S contactor relays with spring terminals
AF..S 3-pole contactors - with spring terminals
Overview
6/44
1-stack contactors
AF09..S … AF26..S
AC / DC operated
6/46
AF09Z..S … AF26Z..S AC / DC operated - low consumption
6/47
2-stack contactors
AF09..S … AF26..S
AC / DC operated
6/48
AF09Z..S … AF26Z..S AC / DC operated - low consumption
6/49
Main accessories
6/50
Technical data
6/52
Electrical durability
6/57
Terminal marking and positioning
6/61
Main dimensions
6/62
6
NF..S contactor relays - with spring terminals
Overview
6/66
4-pole contactor relays
NF..S
AC / DC operated
6/68
NFZ..S
AC / DC operated - low consumption
6/69
8-pole contactor relays
NF..S
AC / DC operated
6/70
NFZ..S
AC / DC operated - low consumption
6/71
Main accessories
6/72
Technical data
6/74
Terminal marking and positioning
6/77
Main dimensions
6/78
Accessories
6/80
Electronic timers - with spring terminals
6/84
Other accessories
6/87
Voltage code table
6/88
Summary_6-2
Auxiliary contact blocks - with spring terminals
ABB | 6/43
3-pole contactors - with spring terminals
Main accessories
AF09..S ... AF16..S
3-pole contactors
AF26..S
3-pole contactors
6
Main accessories for contactors
AF..S contactor
(without top mounted
coil terminal block)
AF..S contactor
Fixing clips
CAT4-11..S
2-pole auxiliary contact
and A1/A2 coil terminal block
AF..S contactor
BX4-CA
Protective cover
VM4
TEF4S
Electronic timer
CA4..S
4-pole auxiliary
contact block
CAL4-11S
2-pole auxiliary
contact block
BX4
Protective cover
CA4..S
1-pole auxiliary
contact block
1SBC101677S0201
Top or bottom
mounted
coil terminal block
BX4-CA
Protective cover
6/44 | ABB
3-pole contactors - with spring terminals
Spring terminals
AC / DC Control voltage
AF09..S
AF12..S
AF16..S
AF26..S
Switching of 3-phase cage motors
Rated operational power
33
M
3
Rated
operational
current
400 V
4 kW
5.5 kW
7.5 kW
11 kW
θ ≤ 60 °C
400 V
9A
12 A
18 A
26 A
θ ≤ 60 °C
415 V
9A
12 A
18 A
26 A
7A
5 hp
9A
7.5 hp
10.5 A
10 hp
17 A
–
00
0
–
–
IEC
AC-3
UL/CSA
690 V
θ ≤ 60 °C
440-480 V
3-phase motor rating
NEMA size
6
Switching of resistive circuits
33
R
R
IEC
UL/CSA
θ ≤ 40 °C
690 V
22 A
24 A
24 A
35 A
θ ≤ 60 °C
690 V
18 A
20 A
20 A
30 A
690 V
θ ≤ 70 °C
With conductor cross-sectional area
15 A
16 A
16 A
25 A
2.5 mm 2
20 A
2.5 mm 2
20 A
2.5 mm 2
20 A
4 mm 2
–
AWG 12
AWG 12
AWG 12
–
AC-1
Rated
operational
current
General use rating
600 V AC
With conductor cross-sectional area
Main accessories
Front mounting
1-pole CA4-10S or CA4-01S
4-pole CA4..S
2-pole CAT4-11..S (with coil front connection)
Interlock
Side mounting
2-pole CAL4-11S
Mechanical
VM4 Including 2 fixing clips
Additional coil
terminal block
LDC4S
Protective covers
BX4 For all 1-stack contactors
BX4-CA For 4-pole CA4..S and 2-pole CAT4..S auxiliary contact blocks
1SBC101677S0201
Auxiliary
contact
blocks
ABB | 6/45
AF09..S ... AF26..S 3-pole contactors - with spring terminals
4 to 11 kW
AC / DC operated
1SBC101099F0014
Description
AF09-30-10S
AF09..S ... AF26..S contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles:
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
1SBC101100F0014
6
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc min. … Uc max.
rating
600 V AC
hp
5
A
20
AF26-30-00S
5.5
7.5
11
24
24
35
7.5
20
10
20
–
–
Auxiliary Type
contacts
fitted
V 50/60 Hz
24...60
V DC
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
-
48...130
48...130
100...250
100...250
250...500
250...500
24...60
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
(1)
(1)
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
AF09-30-10S-41
AF09-30-01S-41
AF09-30-10S-12
AF09-30-01S-12
AF09-30-10S-13
AF09-30-01S-13
AF09-30-10S-14
AF09-30-01S-14
AF12-30-10S-41
AF12-30-01S-41
AF12-30-10S-12
AF12-30-01S-12
AF12-30-10S-13
AF12-30-01S-13
AF12-30-10S-14
AF12-30-01S-14
AF16-30-10S-41
AF16-30-01S-41
AF16-30-10S-12
AF16-30-01S-12
AF16-30-10S-13
AF16-30-01S-13
AF16-30-10S-14
AF16-30-01S-14
AF26-30-00S-41
AF26-30-00S-12
AF26-30-00S-13
AF26-30-00S-14
Order code
Weight
Pkg
(1 pce)
1SBL137004R4110
1SBL137004R4101
1SBL137004R1210
1SBL137004R1201
1SBL137004R1310
1SBL137004R1301
1SBL137004R1410
1SBL137004R1401
1SBL157004R4110
1SBL157004R4101
1SBL157004R1210
1SBL157004R1201
1SBL157004R1310
1SBL157004R1301
1SBL157004R1410
1SBL157004R1401
1SBL177004R4110
1SBL177004R4101
1SBL177004R1210
1SBL177004R1201
1SBL177004R1310
1SBL177004R1301
1SBL177004R1410
1SBL177004R1401
1SBL237004R4100
1SBL237004R1200
1SBL237004R1300
1SBL237004R1400
kg
0.270
0.270
0.270
0.270
0.270
0.270
0.310
0.310
0.270
0.270
0.270
0.270
0.270
0.270
0.310
0.310
0.270
0.270
0.270
0.270
0.270
0.270
0.310
0.310
0.320
0.320
0.320
0.360
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use AF..-30-..S-11 (see voltage code table).
AF..-30-..S-11 not suitable for direct control by PLC-output.
mm, inches
86 3.38"
77 3.03"
45 1.77"
80 3.15"
45 1.77"
71 2.79"
5.5
0.22"
5.5 0.22"
10 0.39"
AF09..S, AF12..S, AF16..S
6/46 | ABB
35 mm EN/IEC 60715
10 0.39"
82.5 3.24"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
5.5 0.22"
10 0.39"
AF26..S
1SBC101688S0201 - Rev. A
Main dimensions
AF09Z..S ... AF26Z..S 3-pole contactors - with spring terminals
4 to 11 kW
AC / DC operated - low consumption
1SBC101099F0014
Description
AF09Z-30-10S
AF09Z..S ... AF26Z..S contactors are mainly used for controlling 3-phase motors and power circuits up
to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles:
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and
12...250 V DC
-- can manage large control voltage variations
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc min. … Uc max.
rating
600 V AC
hp
5
A
20
AF26Z-30-00S
5.5
7.5
11
24
24
35
7.5
20
10
20
–
–
V 50/60 Hz
–
V DC
12...20
24...60
20...60
48...130
48...130
100...250
100...250
–
12...20
24...60
20...60
48...130
48...130
100...250
100...250
–
12...20
24...60
20...60
48...130
48...130
100...250
100...250
–
24...60
48...130
100...250
12...20
20...60
48...130
100...250
Auxiliary Type
contacts
fitted
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
AF09Z-30-10S-20
AF09Z-30-01S-20
AF09Z-30-10S-21
AF09Z-30-01S-21
AF09Z-30-10S-22
AF09Z-30-01S-22
AF09Z-30-10S-23
AF09Z-30-01S-23
AF12Z-30-10S-20
AF12Z-30-01S-20
AF12Z-30-10S-21
AF12Z-30-01S-21
AF12Z-30-10S-22
AF12Z-30-01S-22
AF12Z-30-10S-23
AF12Z-30-01S-23
AF16Z-30-10S-20
AF16Z-30-01S-20
AF16Z-30-10S-21
AF16Z-30-01S-21
AF16Z-30-10S-22
AF16Z-30-01S-22
AF16Z-30-10S-23
AF16Z-30-01S-23
AF26Z-30-00S-20
AF26Z-30-00S-21
AF26Z-30-00S-22
AF26Z-30-00S-23
Order code
Weight
Pkg
(1 pce)
1SBL136004R2010
1SBL136004R2001
1SBL136004R2110
1SBL136004R2101
1SBL136004R2210
1SBL136004R2201
1SBL136004R2310
1SBL136004R2301
1SBL156004R2010
1SBL156004R2001
1SBL156004R2110
1SBL156004R2101
1SBL156004R2210
1SBL156004R2201
1SBL156004R2310
1SBL156004R2301
1SBL176004R2010
1SBL176004R2001
1SBL176004R2110
1SBL176004R2101
1SBL176004R2210
1SBL176004R2201
1SBL176004R2310
1SBL176004R2301
1SBL236004R2000
1SBL236004R2100
1SBL236004R2200
1SBL236004R2300
6
kg
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.360
0.360
0.360
0.360
Note: Only AF..Z..S contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the
coil terminals: A1+ for the positive pole and A2- for the negative pole.
mm, inches
86 3.38"
77 3.03"
45 1.77"
80 3.15"
45 1.77"
71 2.79"
5.5
0.22"
5.5 0.22"
10 0.39"
AF09Z..S, AF12Z..S, AF16Z..S
35 mm EN/IEC 60715
10 0.39"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
5.5 0.22"
10 0.39"
AF26Z..S
ABB | 6/47
1SBC101709S0201 - Rev. A
Main dimensions
82.5 3.24"
1SBC101100F0014
Ordering details
AF09..S ... AF26..S 2-stack 3-pole contactors - with spring terminals
4 to 11 kW
AC / DC operated
1SBC101101F0014
Description
AF09-30-22S
AF09..S ... AF26..S contactors are mainly used for controlling 3-phase motors and power circuits up
to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):
–– 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC) only 4 control voltage ranges covering 24...500 V 50/60 Hz and
20...500 V DC
-- can manage large control voltage variations
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
Rated control circuit
General voltage
use
Uc min. … Uc max.
rating
600 V AC
hp
5
A
20
5.5
24
7.5
20
7.5
24
10
20
11
35
–
–
1SBC101103F0014
AF26-30-22S
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
V DC
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
48...130
100...250
250...500
(1)
-
48...130
48...130
100...250
100...250
250...500
250...500
Auxiliary Type
contacts
fitted
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
AF09-30-22S-41
AF09-30-22S-12
AF09-30-22S-13
AF09-30-22S-14
AF12-30-22S-41
AF12-30-22S-12
AF12-30-22S-13
AF12-30-22S-14
AF16-30-22S-41
AF16-30-22S-12
AF16-30-22S-13
AF16-30-22S-14
AF26-30-11S-41
AF26-30-22S-41
AF26-30-11S-12
AF26-30-22S-12
AF26-30-11S-13
AF26-30-22S-13
AF26-30-11S-14
AF26-30-22S-14
Order code
Pkg
(1 pce)
kg
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.360
0.380
0.360
0.380
0.360
0.380
0.400
0.420
1SBL137004R4122
1SBL137004R1222
1SBL137004R1322
1SBL137004R1422
1SBL157004R4122
1SBL157004R1222
1SBL157004R1322
1SBL157004R1422
1SBL177004R4122
1SBL177004R1222
1SBL177004R1322
1SBL177004R1422
1SBL237004R4111
1SBL237004R4122
1SBL237004R1211
1SBL237004R1222
1SBL237004R1311
1SBL237004R1322
1SBL237004R1411
1SBL237004R1422
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use AF..-30-..S-11 (see voltage code table).
AF..-30-..S-11 not suitable for direct control by PLC-output.
Main dimensions
mm, inches
111 4.37"
45 1.77"
71 2.79"
113 4.45"
120 4.72"
10 0.39"
5.5
0.22"
AF26..S
35 mm EN/IEC 60715
10 0.39"
82.5 3.24"
45 1.77"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
AF09..S, AF12..S, AF16..S
5.5 0.22"
AF26-30-11S
AF26-30-22S
80 3.15"
45 1.77"
10 0.39"
5.5
0.22"
6/48 | ABB
Weight
5.5 0.22"
45 1.77"
AF26-30-11S
UL/CSA
3-phase
motor
rating
480 V
1SBC101710S0201 - Rev. A
1SBC101102F0014
6
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
AF09Z..S ... AF26Z..S 2-stack 3-pole contactors - with spring terminals
4 to 11 kW
AC / DC operated - low consumption
1SBC101101F0014
Description
AF09Z-30-22S
AF09Z..S ... AF26Z..S contactors are mainly used for controlling 3-phase motors and power circuits up to
690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles (1st stack):
–– 2nd stack with permanently fixed auxiliary contact block. The built-in auxiliary contact elements are mechanically linked (side-marked symbol) and the N.C. auxiliary contacts are mirror contacts
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage
range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...250 V 50/60 Hz and
12...250 V DC
-- can manage large control voltage variations
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
IEC
Rated operational
power
current
θ ≤ 40 °C
400 V
AC-3
AC-1
kW
A
4
22
UL/CSA
3-phase
motor
rating
480 V
Rated control circuit
General voltage
use
Uc min. … Uc max.
rating
600 V AC
hp
5
A
20
5.5
24
7.5
20
7.5
24
10
20
11
35
–
–
AF26Z-30-22S
V DC
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
24...60
20...60
48...130
48...130
100...250
100...250
Auxiliary Type
contacts
fitted
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
2
AF09Z-30-22S-20
AF09Z-30-22S-21
AF09Z-30-22S-22
AF09Z-30-22S-23
AF12Z-30-22S-20
AF12Z-30-22S-21
AF12Z-30-22S-22
AF12Z-30-22S-23
AF16Z-30-22S-20
AF16Z-30-22S-21
AF16Z-30-22S-22
AF16Z-30-22S-23
AF26Z-30-11S-20
AF26Z-30-22S-20
AF26Z-30-11S-21
AF26Z-30-22S-21
AF26Z-30-11S-22
AF26Z-30-22S-22
AF26Z-30-11S-23
AF26Z-30-22S-23
Order code
Weight
Pkg
(1 pce)
6
kg
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.400
0.420
0.400
0.420
0.400
0.420
0.400
0.420
1SBL136004R2022
1SBL136004R2122
1SBL136004R2222
1SBL136004R2322
1SBL156004R2022
1SBL156004R2122
1SBL156004R2222
1SBL156004R2322
1SBL176004R2022
1SBL176004R2122
1SBL176004R2222
1SBL176004R2322
1SBL236004R2011
1SBL236004R2022
1SBL236004R2111
1SBL236004R2122
1SBL236004R2211
1SBL236004R2222
1SBL236004R2311
1SBL236004R2322
Note: Only AF..Z..S contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the
coil terminals: A1+ for the positive pole and A2- for the negative pole.
mm, inches
111 4.37"
71 2.79"
80 3.15"
45 1.77"
10 0.39"
35 mm EN/IEC 60715
10 0.39"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
AF09Z..S, AF12Z..S, AF16Z..S
10 0.39"
5.5
0.22"
5.5
0.22"
5.5 0.22"
113 4.45"
120 4.72"
5.5 0.22"
AF26Z..S
ABB | 6/49
1SBC101711S0201 - Rev. A
45 1.77"
AF26-30-11S
AF26-30-22S
45 1.77"
Main dimensions
82.5 3.24"
1SBC101103F0014
AF26Z-30-11S
V 50/60 Hz
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
45 1.77"
1SBC101102F0014
Ordering details
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Main accessories
Contactor and main accessories (other accessories available)
AF..S contactor
(without top mounted
coil terminal block)
AF..S contactor
Fixing clips
CAT4-11..S
2-pole auxiliary contact
and A1/A2 coil terminal block
AF..S contactor
BX4-CA
Protective cover
6
VM4
TEF4S
Electronic timer
CA4..S
4-pole auxiliary
contact block
CAL4-11S
2-pole auxiliary
contact block
Top or bottom
mounted
coil terminal block
BX4
Protective cover
BX4-CA
Protective cover
CA4..S
1-pole auxiliary
contact block
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor
types
Built-in
Front-mounted accessories
auxiliary Auxiliary contact blocks
contacts
Main
poles
1-pole CA4..S
2-pole CAT4-11..S
4-pole CA4..S
Side-mounted accessories
Auxiliary contact blocks
Electronic
timer
Mechanical
interlock unit
(between 2 contactors)
Left side
TEF4S
VM4
2-pole CAL4-11S
Right side
Max. N.C. built-in and add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5
0
0
1
AF09..S ... AF16..S 3
AF26..S
3
0
0
1
0
0
0
AF26..S
3
AF09..S ... AF26..S 3
0
0
1
2
1
2
4
2
3
4
2
3
–
–
max.
max.
max.
max.
max.
max.
or 1
–
–
or 1
or 1
–
–
–
or 1
–
–
or 1
–
–
–
–
or 1
or 1
–
or 1
or 1
–
–
–
–
–
+ 1
–
–
+ 1
–
–
+
+
+
+
+
+
1
1
1
1
1
1
1
1
–
+ 1
or 1
–
+ 1
or 1
+ 1
–
1SBC101661S0201
AF09..S ... AF16..S 3
6/50 | ABB
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Main accessories
Ordering details (1)
Auxiliary Type
contacts
1SBC101110F0014
For contactors
Pkg
qty
Weight
(1 pce)
kg
CA4-10S
Front-mounted instantaneous auxiliary contact blocks
1
1
0
0
2
3
2
3
4
1SBC101125F0014
AF09..S ... AF26..S
CA4-22MS
AF09 ... AF16..-30-10S
1SBC101113F0014
AF26..S
0
0
1
1
2
1
2
1
0
CA4-10S
CA4-10S-T
CA4-01S
CA4-01S-T
CA4-22MS
CA4-31MS
CA4-22ES
CA4-31ES
CA4-40ES
1SBN010119R1010
1SBN010119T1010
1SBN010119R1001
1SBN010119T1001
1SBN010145R1122
1SBN010145R1131
1SBN010145R1022
1SBN010145R1031
1SBN010145R1040
1
10
1
10
1
1
1
1
1
0.016
0.016
0.016
0.016
0.060
0.060
0.060
0.060
0.060
1SBN010130R1011
1
0.045
1
1
1
0.045
0.045
0.045
Pkg
qty
Weight
(1 pce)
Side-mounted instantaneous auxiliary contact blocks
AF09..S ... AF26..S
CAL4-11S
1
1
CAL4-11S
6
1SBC101117F0014
Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks
CAT4-11ES
AF09 ... AF16..-30-10S
AF26..S
AF09 ... AF16..-30-01S
1
1
1
CAT4-11MS 1SBN010153R1111
CAT4-11ES 1SBN010153R1011
CAT4-11US 1SBN010153R1311
Ordering details (1)
Time delay
range
Delay
type
1SBC101393F0014
selected by
switch
Rated control
circuit voltage
Uc
Auxiliary Type
contacts
Order code
V 50/60 Hz or DC
kg
Front-mounted electronic timer
AF09..S ... AF26..S
1SBC101128F0014
TEF4S-OFF
VM4
0.1...1 s
1...10 s
10...100 s
ON-delay
24...240
1
1
TEF4S-ON
1SBN020113R1000
1
0.065
OFF-delay 24...240
1
1
TEF4S-OFF 1SBN020115R1000
1
0.065
Type
Pkg
qty
Weight
(1 pce)
1SBC101135F0014
Ordering details (1)
1SBC101136F0014
For contactors
LDC4S
1
1
1
Note: CAT4 not fittable on AF..Z contactors with DC control voltage 12…20 V DC.
For contactors
1SBC101138F0014
Order code
Order code
kg
Mechanical interlock unit
AF09..S ... AF26..S
VM4
1SBN030105T1000
10
0.005
LDC4S
1SBN070157T1000
10
0.010
BX4
BX4-CA
1SBN110108T1000
1SBN110109W1000
10
50
0.006
0.001
Note: VM4 includes 2 fixing clips (BB4) to maintain together both contactors.
BX4
Additional coil terminal block
AF09..S ... AF26..S
BX4-CA
Protective covers
All 1-stack contactors
For 4-pole CA4..S and 2-pole CAT4..S auxiliary contact blocks
1SBC101703S0201 - Rev. A
(1) See "Main accessory fitting details" table.
Note: Following accessories can be used on 3-pole contactors AF09 ... AF96 with screw terminals :
- 1 or 4-pole CA4...S auxiliary contact blocks
- 2-pole CAL4-11S auxiliary contact blocks
- TEF4S electronic timer
- LDC4S coil terminal block.
ABB | 6/51
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Technical data
Main pole - Utilization characteristics according to IEC
Contactor types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith
AF09..S
AF12..S
AF16..S
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1
690 V
50/60 Hz
AF26..S
24 A
2.5 mm²
24 A
2.5 mm²
24 A
2.5 mm²
35 A
4 mm²
22 A
18 A
15 A
2.5 mm²
24 A
20 A
16 A
2.5 mm²
24 A
20 A
16 A
2.5 mm²
35 A
30 A
25 A
4 mm²
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
9A
9A
9A
9A
9.5 A
7A
12 A
12 A
12 A
12 A
12.5 A
9A
18 A
18 A
18 A
18 A
15 A
10.5 A
26
26
26
26
23
17
220-230-240 V
380-400 V
415 V
440 V
500 V
690 V
2.2 kW
3 kW
4 kW
5.5 kW
4 kW
5.5 kW
4 kW
5.5 kW
5.5 kW
7.5 kW
5.5 kW
7.5 kW
10 x Ie AC-3 acc. to IEC 60947-4-1
8 x Ie AC-3 acc. to IEC 60947-4-1
4 kW
7.5 kW
9 kW
9 kW
9 kW
9 kW
6.5 kW
11 kW
11 kW
15 kW
15 kW
15 kW
12 A
5.5 kW
16 A
7.5 kW
22 A
11 kW
30 A
15 kW
25 A
300 A
150 A
80 A
60 A
24 A
25 A
300 A
150 A
80 A
60 A
24 A
40 A
700 A
350 A
225 A
150 A
35 A
250 A
106 A
1.1 W
0.3 W
250 A
106 A
1.1 W
0.6 W
500 A
200 A
1.8 W
1W
AC / DC operated
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 40 °C
θ ≤ 60 °C
θ ≤ 70 °C
With conductor cross-sectional area
AC-3 Utilization category
For air temperature close to contactor θ ≤ 60 °C
Ie / Max. rated operational current AC-3 (1)
M
3
3-phase motors
A
A
A
A
A
A
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz
1800 r.p.m. 60 Hz
3-phase motors
Rated making capacity AC-3
Rated breaking capacity AC-3
AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a
Rated operational power AC-8a
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2)
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,
in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
Power dissipation per pole
Max. electrical switching frequency
25 A
300 A
150 A
80 A
1 min 60 A
15 min 24 A
1 s
10 s
30 s
at 440 V
at 690 V
Ie / AC-1
Ie / AC-3
AC-1
AC-3
AC-2, AC-4
250 A
106 A
0.9 W
0.15 W
600 cycles/h
1200 cycles/h
300 cycles/h
150 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
1SBC101689S0201 - Rev. A
6
6/52 | ABB
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Technical data
Main pole - Utilization characteristics according to UL / NEMA / CSA
AC / DC operated
Contactor types
Standards
Max. operational voltage
NEMA size
Thermal current
NEMA continuous amp rating
115 V AC
NEMA maximum horse power ratings 1-phase, 60 Hz
NEMA maximum horse power ratings 3-phase, 60 Hz
UL / CSA General use rating
600 V AC
With conductor cross-sectional area
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
230 V AC
200 V AC
230 V AC
460 V AC
575 V AC
120 V AC
240 V AC
120 V AC
240 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
200-208 V AC
220-240 V AC
440-480 V AC
550-600 V AC
AF09..S
AF12..S
UL 508, CSA C22.2 N°14
690 V
00
0
9A
18 A
1/3 hp
1 hp
1 hp
2 hp
1-1/2 hp
3 hp
1-1/2 hp
3 hp
2 hp
5 hp
2 hp
5 hp
AF16..S
AF26..S
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
20 A
AWG 12
20 A
AWG 12
20 A
AWG 12
–
–
13.8 A
10 A
3/4 hp
1 1/2 hp
16 A
12 A
1 hp
2 hp
16 A
12 A
1 hp
2 hp
–
–
–
–
7.8 A
6.8 A
7.6 A
9A
2 hp
2 hp
5 hp
7.5 hp
11 A
9.6 A
11 A
11 A
3 hp
3 hp
7.5 hp
10 hp
11 A
15.2 A
14 A
11 A
3 hp
5 hp
10 hp
10 hp
–
–
–
–
–
–
–
–
30
J
30
J
60
J
–
–
600 cycles/h
1200 cycles/h
600 cycles/h
1200 cycles/h
600 cycles/h
1200 cycles/h
–
–
6
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded
Fuse rating
Fuse type, 600 V
Max. electrical switching frequency
For general use
For motor use
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents".
General technical data
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
B2
C2
Vibration withstand
acc. to IEC 60068-2-6
AC / DC operated
AF09..S
AF12..S
AF16..S
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A
AF26..S
–
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
3000 m
10 millions operating cycles
3600 cycles/h
Shock direction
A
B1
B2
C1
C2
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
30 g
25 g closed position / 5 g open position
15 g
25 g
25 g
5...300 Hz
4 g closed position / 2 g open position
ABB | 6/53
1SBC101689S0201 - Rev. A
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1
acc. to UL / CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor
Operation without thermal overload relay
Storage
Climatic withstand
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Technical data
Magnet system characteristics
Contactor types
Coil operating limits
AC / DC operated
AC supply
acc. to IEC 60947-4-1
AF09..S
AF12..S
At θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C 0.85 x Uc min...Uc max.
AF16..S
AF26..S
At θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
At θ ≤ 70 °C (AF) 0.85 x Uc min...Uc max. - (AF..Z) 0.85 x Uc min...1.1 x Uc max.
AC control voltage Rated control circuit voltage Uc
24...500 V AC
Average pull-in value (AF) 50 VA - (AF..Z) 16 VA
50/60 Hz
Coil consumption
Average holding value (AF) 2.2 VA / 2 W - (AF..Z) 1.7 VA / 1.5 W
DC control voltage Rated control circuit voltage Uc
12...500 V DC
Average pull-in value (AF) 50 W - (AF..Z) 12...16 W
Coil consumption
Average holding value (AF) 2 W - (AF..Z) 1.7 W
PLC-output control
(AF..Z) ≥ 500 mA 24 V DC
Drop-out voltage
≤ 60 % of Uc min.
Voltage sag immunity
(AF..Z) conditions of use on request
DC supply
acc. to SEMI F47-0706
(AF..Z) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DC
Dips withstand
-20 °C ≤ θ ≤ +60°C
Operating time
Between coil energization and:
Between coil de-energization and:
N.O. contact closing
N.C. contact opening
N.O. contact opening
N.C. contact closing
40...95
38...90
11...95
13...98
ms
ms
ms
ms
Mounting characteristics and conditions for use
Contactor types
Mounting positions
AC / DC operated
AF09..S
AF12..S
Pos. 2
+30°
AF16..S
AF26..S
-30°
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
Max. N.C. built-in and add-on N.C. auxiliary contacts:
see accessory fitting details for a 3-pole contactor AF09..S ... AF26..S
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
The contactors can be assembled side by side
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
1SBC101689S0201 - Rev. A
6
6/54 | ABB
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Technical data
Connecting characteristics
Contactor types
Main terminals
AC / DC operated
AF09..S
AF12..S
AF16..S
AF26..S
Spring terminals
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid
Solid (≤ 4 mm²)
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL/CSA
Stripping length
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL/CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
1 or 2 x
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...12
10 mm
1x
2x
1x
2x
1x
2x
1 or 2 x
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...14
10 mm
1.5...4 mm²
1.5...4 mm²
1.5...4 mm²
1.5...4 mm²
1.5...4 mm²
1.5...4 mm²
–
14 mm
6
–
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screwdriver type
IP20
IP20
IP20
Flat Ø 3.5
1SBC101689S0201 - Rev. A
Main terminals
Coil terminals
Built-in auxiliary terminals
ABB | 6/55
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Technical data
Built-in auxiliary contacts according to IEC
AC / DC operated
Contactor types
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free air thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity AC-15
Breaking capacity AC-15
Ie / Rated operational current DC-13
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
acc. to IEC 60947-5-1
6
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
AC-15
DC-13
Mechanically linked contacts
(according to annex L of IEC 60947-5-1)
Mirror contacts
(according to annex F of IEC 60947-4-1)
AF09..S
690 V
50/60 Hz
16 A
AF12..S
AF16..S
AF26..S
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
≥ 2 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4..S,
CAL4..S, CAT4..S aux. contact blocks) are mechanically linked contacts.
Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA4..S, CAL4..S, CAT4..S aux.
contact blocks) are mirror contacts.
Built-in auxiliary contacts according to UL / CSA
AC / DC operated
AF09..S
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
AF12..S
AF16..S
AF26..S
–
–
–
–
–
–
–
1SBC101689S0201 - Rev. A
Contactor types
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
6/56 | ABB
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Contactor electrical durability and utilization categories
General
Utilization categories determine the current making and breaking conditions relating to the characteristics of the loads to be controlled by the contactors.
International standard IEC 60947-4-1 and European standard EN 60947-4-1 are the standards to be referred to.
If Ic is the current to be broken by the contactor and Ie the rated operational current normally drawn by the load, then:
–– Categories AC-1 and AC-3: Ic = Ie
–– Category AC-2: Ic = 2.5 x Ie
–– Category AC-4: Ic = 6 x Ie
Generally speaking Ic = m x Ie where m is a multiple of the load operational current.
On next pages, the curves corresponding to categories AC-1, AC-3, AC-2 and AC-4 represent the electrical durability variation of standard contactors in
relation to the breaking current Ic.
Electrical durability is expressed in millions of operating cycles.
Curve utilization mode
Electrical durability forecast and contactor selection for categories AC-1, AC-2, AC-3 or AC-4
• Note the characteristics of the load to be controlled:
–– Operational voltage ........................................................................... Ue
–– Current normally drawn ..................................................................... Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents").
–– Utilization category ............................................................................ AC-1, AC-2, AC-3 or AC-4
–– Breaking current ................................................................................ Ic = Ie for AC-1 and for AC-3 ; Ic = 2.5 x Ie for AC-2 ; Ic = 6 x Ie for AC-4
• Define the number of operating cycles N required.
• On the diagram corresponding to the operational category, select the contactor with the curve immediately above the intersection point (Ic ; N).
6
Electrical durability forecast and contactor selection for mixed duty motor control: AC-3 (Ic = Ie) type switching off while
"motor running" and, occasionally, AC-4 (Ic = 6 x Ie) type switching off while "motor accelerating"
• Note the characteristics of the motor to be controlled:
–– Operational voltage ........................................................................... Ue
–– Current normally drawn while "motor running" .................................. Ie (Ue / Ie / kW relation for motors, see "Motor rated operational powers and currents")
–– Breaking current for AC-3 .................................................................. Ic = Ie
–– Breaking current for AC-4 while "motor accelerating" ........................ Ic = 6 x Ie
–– Percentage of AC-4 operating cycles ................................................ K (on the basis of the total number of operating cycles)
• Define the total number of operating cycles N required.
• Note the smallest contactor rating compatible for AC-3 (Ue / Ie) on Main pole utilization characteristic table (see “Technical data”).
• For the selected contactor make a note of the following in relation to the voltage using diagram AC-3 in next pages:
–– The number of operating cycles A for Ic = Ie (AC-3)
–– The number of operating cycles B for Ic = 6 x Ie (AC-4)
• Calculate the estimated number of cycles N’ (N’ is always below A)
A
1 + 0.01 K (A/B - 1)
N'=
• If N' is too low in relation to the target N, calculate the estimated number of cycles for a higher contactor rating.
Case of uninterrupted duty
1SBC101933S0201
For uninterrupted duty, some verifications of preventing maintenance are necessary to check the functionality of the concerned product (consult us).
The combinated effect of environmental conditions and the proper temperature of the product may require some disposals. As a matter of fact, for this duty,
the use duration prevails over the number of operating cycles.
ABB | 6/57
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Electrical durability
Millions of
operating
cycles
..S
26
AF
.
AF .S
16
..S
12
AF
AF
09
..S
Electrical durability for AC-1 utilization category - Ue ≤ 690 V. Ambient temperature ≤ 60 °C
Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of
the load.
Maximum electrical switching frequency: see "Technical data".
10
5
3
9
7
5
3
1
2
9
7
5
6
3
1
1
0.5
0.3
9
7
5
3
1
0.2
1 3 5 7 9
1
0.1
2
3
5
3
5
7
10
9
20
1 3 5 79
30
50
100
Breaking current Ic (A)
1SBC101934S0201
AF09..S … AF26..S 3-pole contactors AC-1 electrical durability
6/58 | ABB
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Electrical durability
Electrical durability for AC-3 utilization category
Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current). Maximum electrical switching frequency: see "Technical data".
Millions of
operating
cycles
..S
..S
26
AF
AF
16
..S
12
AF
AF
09
..S
AC-3 - Ue ≤ 440 V - Ambient temperature ≤ 60 °C
10
5
3
9
7
5
3
1
2
9
7
6
5
3
1
1
0.5
0.3
0.2
1 3 5 7 9
1 3 5 7 9
1
2
3
5
3
5
7
10
9
20
30
50
100
Breaking current Ic (A)
AF09..S … AF26..S 3-pole contactors AC-3 electrical durability for Ue ≤ 440 V
..S
26
AF
AF
Millions of
operating
cycles
AF
09
.
.S
12
AF ..S
16
..S
AC-3 - 440 V < Ue ≤ 690 V - Ambient temperature ≤ 60 °C
10
5
3
9
7
5
3
1
2
9
7
5
3
1
1
0.5
0.2
1 3 5 7 9
1
2
3
5
10
3
5
7
1SBC101935S0201
0.3
9
20
30
50
100
Breaking current Ic (A)
AF09..S … AF26..S 3-pole contactors AC-3 electrical durability for 440 V < Ue ≤ 690 V
ABB | 6/59
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Electrical durability
Electrical durability for AC-2 or AC-4 utilization category
Switching cage motors: starting, reverse operation and step-by-step operation. The breaking current Ic is equal to 2.5 x Ie for
AC-2 and 6 x Ie for AC-4, keeping in mind that Ie is the motor rated operational current (Ie = motor full-load current).
Maximum electrical switching frequency: see "Technical data".
AF
09
AF ..S
12
..S
AF
16
..
AF S
26
..S
AC-2 or AC-4 - Ue ≤ 440 V - Ambient temperature ≤ 60 °C
10
Millions of
operating
cycles
5
3
9
7
5
3
1
2
9
7
5
3
1
1
0.5
6
0.3
9
7
5
3
1
9
7
5
3
1
0.1
0.05
0.03
9
7
5
3
1
0.02
9
7
5
3
1
0.01
1 3 5 7 9
1
0.005
2
3
5
3
5
7
10
9
1
20
30
50
100
3
5
7
9
200
1000
Breaking current Ic (A)
AF09..S … AF26..S 3-pole contactors AC-2 or AC-4 electrical durability for 440 V < Ue ≤ 690 V
Millions of
operating
cycles
AF ..S
16
AF ..S
26
..S
12
AF
AF
0
9.
.S
AC-2 or AC-4 - 440 V < Ue ≤ 690 V - Ambient temperature ≤ 60 °C
10
5
3
9
7
5
3
1
2
9
7
5
3
1
1
0.5
0.3
9
7
5
3
1
9
7
5
3
1
0.1
0.05
0.03
9
7
5
3
1
9
7
5
3
1
0.01
1 3 5 7 9
1
0.005
2
3
5
10
3
5
7
9
20
30
50
100
200
1000
Breaking current Ic (A)
AF09..S … AF26..S 3-pole contactors AC-2 or AC-4 electrical durability for 440 V < Ue ≤ 690 V
6/60 | ABB
1SBC101936S0201
0.02
AF09..S ... AF26..S 3-pole contactors - with spring terminals
Terminal marking and positioning
AF09..S ... AF26..S contactors - AC / DC operated
Standard devices without addition of auxiliary contacts
2T1 4T2 6T3
13
1L1 3L2 5L3
NC
NO
NC
14
2T1 4T2 6T3
22
2T1
A1 A2
3L2
13 21 31 43
13
2T1
2T1 4T2 6T3
1L1
NO
22
4T2
AF09 ... AF16..-30-22S
3L2
5L3
13
NO
A2
2T1
4T2
6T3
NO
14
6T3
AF09 ... AF16..-30-10S
3L2
A1
1L1
3L2
5L3
21
NC
A2
2T1
4T2
6T3
NC
22
AF09 ... AF16..-30-01S
A1
1L1
3L2
5L3
A2
2T1
4T2
6T3
AF26..-30-00S
5L3
NC
NC
NO
14 22 32 44
2T1
6T3
A1 A2
A1 A2
1L1
13 21 31 43
NC
14
A1
A1 A2
5L3
21
NO
NO
14 22 32 44
4T2
5L3
AF26..-30-00S
A1 A2
1L1
3L2
A1 A2
AF09 ... AF16..-30-01S
1L1 3L2 5L3
NC
1L1
A1 A2
AF09 ... AF16..-30-10S
NC
21
NO
A1 A2
NO
A1 A2
A1 A2
A1 A2
1L1 3L2 5L3
4T2
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
A1
1L1
3L2
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO
44
A2
2T1
4T2
6T3
NO
14
NC
22
6T3
A1 A2
AF26..-30-11S
A1
AF26..-30-22S
AF09 ... AF26..-30-22S
6
AF26..-30-11S
Other possible contact combinations with auxiliary contacts added by the user
A1 A2
1L1 3L2 5L3
NO
21
A1 A2
A1 A2
13
13
1L1
NO
2-
=
NC
22
+
2-
NO
2T1 4T2 6T3
3L2
-1
13 21
NC
NO NC
-2
14 22
A1 A2
5L3
1-
A1 A2
14
2T1
A1 A2
4T2
6T3
NC
13
1L1 3L2 5L3
NO
A1 A2
13
NO
A1 21 33
+
22 34 A2
NC
NO
22 34 A2
NO
2T1 4T2 6T3
NO
13X
21X
=
NC
2T1 4T2 6T3
A1 A2
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
+
NC
NC
22
Combination 11
-2
A1 A2
13
1L1 3L2 5L3
NC NC
NO
NO
14
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
13
NO
=
21 31 43 53
+
NC
NC
NO
NO
22 32 44 54
Combination 21
A1
1L1
3L2
5L3
13
NO
21
NC
31
NC
43 53
NO NO
A2
2T1
4T2
6T3
NO
14
NC
22
NC
32
NO NO
44 54
NO
2T1 4T2 6T3
14
A1 A2
Combination 32 = AF09 ... AF16..-30-10S + CA4-22MS
Combination 32
A1 A2
13
NO
NC
NO
5L3
6T3
22 32 44 54
2T1 4T2 6T3
A1 A2
22X
14X
3L2
A1 A2
NO
A1 A2
1L1 3L2 5L3
4T2
NO
14
Combination 21 = AF09 ... AF16..-30-10S + CAT4-11MS
NO
NO
-1
-4
2-
21 31 43 53
NO
2T1 4T2 6T3
14
13X
21X
1L1
Combination 11 = AF26..-30-00S + CA4-10S + CA4-01S
1L1 3L2 5L3
=
NO
+
2T1
A1 A2
A1 21 33
-3
2-
=
1-
A1
5L3
NO
2T1 4T2 6T3
14
Combination 11 = AF09 ... AF16..-30-10S + CA4-01S
1L1 3L2 5L3
3L2
1L1
NC
NC
NO
22X
14X
14
NO
1L1 3L2 5L3
13
NO
+
A1
1L1
3L2
5L3
13 13X 21X
NO NO NC
A2
2T1
4T2
6T3
NO NO NC
14 14X 22X
NO
2T1 4T2 6T3
14
A1 A2
Combination 21 = CAL4-11S + AF09 ... AF16..-30-10S
Combination 21
Note: Only AF..Z contactor with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.
ABB | 6/61
1SBC101693S0201
1L1 3L2 5L3
AF09..S ... AF16..S 3-pole contactors - with spring terminals
mm, inches
77 3.03"
35 1.38"
71 2.80"
5.5 0.22"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
ø 4.2 0.17"
5.5 0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
80 3.15"
6 0.24"
11.5 0.45"
80 3.15"
45 1.77"
5.5
0.22"
71 2.79"
5 0.20"
77 3.03"
45 1.77"
60 2.36"
Main dimensions
10 0.39"
10 0.39"
5 0.20"
AF09..S, AF12..S, AF16..S
6
77 3.03"
111 4.37"
45 1.77"
71 2.79"
10 0.39"
12 0.47"
71 2.79"
45 1.77"
35 mm EN/IEC 60715
5.5 0.22"
11.5 0.45"
80 3.15"
5.5
0.22"
45 1.77"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
5.5 0.22"
10 0.39"
AF09..S, AF12..S, AF16..S
+ CA4..S 1-pole auxiliary contact block
AF09..S, AF12..S, AF16..S
+ CAL4-11S 2-pole auxiliary contact block
111 4.37"
104 4.09"
10 0.39"
71 2.79"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
6/62 | ABB
5.5 0.22"
10
0.39"
AF09..S, AF12..S, AF16..S
+ CAT4..S 2-pole auxiliary contact and coil terminal block
1SBC101663S0201 - Rev. A
AF09..S, AF12..S, AF16..S
+ CA4..S 4-pole auxiliary contact block
80 3.15"
5.5 0.22"
5.5
0.22"
45 1.77"
45 1.77"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
45 1.77"
71 2.79"
35 mm EN/IEC 60715
45 1.77"
AF26..S 3-pole contactors - with spring terminals
mm, inches
77 3.03"
35 1.38"
71 2.80"
ø 4.2 0.17"
5.5 0.22"
5.5 0.22"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
5.5
0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
6 0.24"
80 3.15"
10 0.39"
82.5 3.24"
45 1.77"
80 3.15"
5 0.20"
86 3.38"
45 1.77"
60 2.36"
Main dimensions
10 0.39"
5 0.20"
10 0.39"
AF26..S
6
120 4.72"
80 3.15"
45 1.77"
86 3.38"
12 0.47"
10 0.39"
80 3.15"
45 1.77"
5.5
0.22"
5.5 0.22"
35 mm EN/IEC 60715
10 0.39"
82.5 3.24"
45 1.77"
82.5 3.24"
35 mm EN/IEC 60715
10 0.39"
5.5
0.22"
5.5 0.22"
10 0.39"
AF26..S
+ CA4..S 1-pole auxiliary contact block
AF26..S
+ CAL4-11S 2-pole auxiliary contact block
113 4.45"
80 3.15"
10 0.39"
35 mm EN/IEC 60715
10
0.39"
5.5 0.22"
AF26..S
+ CAT4..S 2-pole auxiliary contact and coil terminal block
1SBC101664S0201 - Rev. A
AF26..S
+ CA4..S 4-pole auxiliary contact block
82.5 3.24"
5.5 0.22"
5.5
0.22"
45 1.77"
45 1.77"
35 mm EN/IEC 60715
82.5 3.24"
10 0.39"
5.5
0.22"
45 1.77"
120 4.72"
80 3.15"
45 1.77"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 6/63
AF09..S ... AF26..S 3-pole contactors - with spring terminals
mm, inches
133.5 5.26"
77 3.03"
10 0.39"
71 2.80"
35 1.38"
ø 4.2 0.17"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
60 2.36"
5.5 0.22"
5 0.20"
1.1 0.04"
35 mm EN/IEC 60715
80 3.15"
71 2.79"
45 1.77"
5.5
0.22"
6 0.24"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
45 1.77"
41.3 1.63"
Main dimensions
10 0.39"
5 0.20"
AF09..S, AF12..S, AF16..S
+ TEF4S
6
142.5 5.61"
77 3.03"
10 0.39"
71 2.80"
35 1.38"
ø 4.2 0.17"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
60 2.36"
5.5 0.22"
5 0.20"
1.1 0.04"
41.3 1.63"
80 3.15"
6 0.24"
35 mm EN/IEC 60715
82.5 3.24"
10 0.39"
45 1.77"
5.5
0.22"
80 3.15"
35 mm EN/IEC 60715
45 1.77"
10 0.39"
5 0.20"
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
6/64 | ABB
1SBC101702S0201
AF26..S
+ TEF4S
AF09..S ... AF26..S 2-stack 3-pole contactors - with spring terminal
mm, inches
110.5 4.35"
10 0.39"
71 2.80"
10 0.39"
35 1.38"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
60 2.36"
ø 4.2 0.17"
43 1.69"
5.5 0.22"
35 mm EN/IEC 60715
6 0.24"
35 mm EN/IEC 60715
80 3.15"
11.5 0.45"
80 3.15"
45 1.77"
5.5
0.22"
71 2.79"
5 0.20"
111 4.37"
45 1.77"
45 1.77"
Main dimensions
5 0.20"
AF09, AF12, AF16..-30-22S
6
113 4.45"
80 3.15"
45 1.77"
10
0.39"
45 1.77"
82.5 3.24"
35 mm EN/IEC 60715
10 0.39"
5.5
0.22"
5.5 0.22"
AF26..-30-11S
120 4.72"
80 3.15"
45 1.77"
10 0.39"
5.5 0.22"
45 1.77"
35 mm EN/IEC 60715
82.5 3.24"
10 0.39"
5.5
0.22"
1SBC101665S0201
AF26..-30-22S
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 6/65
Contactor relays - with spring terminals
Main accessories
NF22ES, NF31ES and NF40ES
4-pole contactor relays
NF44ES, NF53ES, NF62ES,
NF71ES and NF80ES
8-pole contactor relays
6
Main accessories for contactor relays
NF..S contactor relay
TEF4S
Electronic timer
Top or bottom
mounted
coil terminal block
CA4..S
4-pole auxiliary
contact block
CAL4-11S
2-pole auxiliary
contact block
BX4-CA
Protective cover
CA4..S
1-pole auxiliary
contact block
1SBC101678S0201
BX4
Protective cover
6/66 | ABB
Contactor relays - with spring terminals
Spring terminals
AC / DC Control voltage
NF22ES
NF31ES
NF40ES
2N.O. + 2N.C.
3N.O. + 1N.C.
4N.O.
6
AC / DC Control supply
NF44ES
NF53ES
NF62ES
NF71ES
NF80ES
4N.O. + 4N.C.
5N.O. + 3N.C.
6N.O. + 2N.C.
7N.O. + 1N.C.
8N.O.
Control circuit switching
IEC
AC-15 Rated operational current
DC-13 Rated operational current
240 V
4A
400 V
3A
690 V
2A
6 A / 144 W
24 V
250 V
UL/CSA
Pilot Duty
0.27 A / 68 W
A600, Q600
Main accessories
Front mounting
1-pole CA4-10S or CA4-01S
4-pole CA4..S
Side mounting
2-pole CAL4-11S
Additional coil
terminal block
LDC4S
Protective covers
BX4 For all 1-stack contactor relays
BX4-CA For 4-pole CA4..S auxiliary contact blocks
1SBC101678S0201
Auxiliary
contact
blocks
ABB | 6/67
NF..S 4-pole contactor relays - with spring terminals
AC / DC operated
Description
1SBC101106F0014
NF..S contactor relays are used for switching auxiliary and control circuits.
NF22ES
These contactors relays are of the block type design with:
–– 4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Ordering details
Number of contacts
Rated control circuit
voltage
Uc min. ... Uc max.
6
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
Type
V DC
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
(1)
(1)
(1)
NF22ES-41
NF22ES-12
NF22ES-13
NF22ES-14
NF31ES-41
NF31ES-12
NF31ES-13
NF31ES-14
NF40ES-41
NF40ES-12
NF40ES-13
NF40ES-14
Order code
Weight
1SBH137004R4122
1SBH137004R1222
1SBH137004R1322
1SBH137004R1422
1SBH137004R4131
1SBH137004R1231
1SBH137004R1331
1SBH137004R1431
1SBH137004R4140
1SBH137004R1240
1SBH137004R1340
1SBH137004R1440
Pkg
(1 pce)
kg
0.270
0.270
0.270
0.310
0.270
0.270
0.270
0.310
0.270
0.270
0.270
0.310
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use NF..ES-11 (see voltage code table).
NF..ES-11 not suitable for direct control by PLC-output.
Main dimensions
mm, inches
77 3.03"
45 1.77"
71 2.79"
5.5 0.22"
10 0.39"
NF22ES, NF31ES, NF40ES
6/68 | ABB
1SBC101691S0201 - Rev. A
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
NFZ..S 4-pole contactor relays - with spring terminals
AC / DC operated - low consumption
Description
Ordering details
Number of contacts
A1
13
NO
21
NC
31
NC
43
NO
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
Rated control circuit
voltage
Uc min. ... Uc max.
V 50/60 Hz
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
24...60
48...130
100...250
Type
V DC
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
NFZ22ES-20
NFZ22ES-21
NFZ22ES-22
NFZ22ES-23
NFZ31ES-20
NFZ31ES-21
NFZ31ES-22
NFZ31ES-23
NFZ40ES-20
NFZ40ES-21
NFZ40ES-22
NFZ40ES-23
Order code
Weight
1SBH136004R2022
1SBH136004R2122
1SBH136004R2222
1SBH136004R2322
1SBH136004R2031
1SBH136004R2131
1SBH136004R2231
1SBH136004R2331
1SBH136004R2040
1SBH136004R2140
1SBH136004R2240
1SBH136004R2340
Pkg
(1 pce)
kg
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
6
Note: Only NFZ..S contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to
the coil terminals: A1+ for the positive pole and A2- for the negative pole.
Main dimensions
mm, inches
77 3.03"
45 1.77"
71 2.79"
1SBC101712S0201 - Rev. A
35 mm EN/IEC 60715
5.5
0.22"
11.5 0.45"
NFZ22ES
These contactors relays are of the block type design with:
–– 4 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol)
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
80 3.15"
1SBC101106F0014
NFZ..S contactor relays are used for switching auxiliary and control circuits.
5.5 0.22"
10 0.39"
NFZ22ES, NFZ31ES, NFZ40ES
ABB | 6/69
NF..S 8-pole contactor relays - with spring terminals
AC / DC operated
Description
1SBC101107F0014
NF..S contactor relays are used for switching auxiliary and control circuits.
NF44ES
These contactors relays are of the block type design with:
–– 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked auxiliary
contact elements (side-marked symbol)
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC
-- reduced panel energy consumption
-- very distinct closing and opening.
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
Ordering details
Number of contacts
1st stack
Rated control circuit
voltage
Uc min. ... Uc max.
2nd stack
6
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
V 50/60 Hz
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
24...60
48...130
100...250
250...500
Type
V DC
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
48...130
100...250
250...500
(1)
(1)
(1)
(1)
(1)
NF44ES-41
NF44ES-12
NF44ES-13
NF44ES-14
NF53ES-41
NF53ES-12
NF53ES-13
NF53ES-14
NF62ES-41
NF62ES-12
NF62ES-13
NF62ES-14
NF71ES-41
NF71ES-12
NF71ES-13
NF71ES-14
NF80ES-41
NF80ES-12
NF80ES-13
NF80ES-14
Order code
Weight
1SBH137004R4144
1SBH137004R1244
1SBH137004R1344
1SBH137004R1444
1SBH137004R4153
1SBH137004R1253
1SBH137004R1353
1SBH137004R1453
1SBH137004R4162
1SBH137004R1262
1SBH137004R1362
1SBH137004R1462
1SBH137004R4171
1SBH137004R1271
1SBH137004R1371
1SBH137004R1471
1SBH137004R4180
1SBH137004R1280
1SBH137004R1380
1SBH137004R1480
Pkg
(1 pce)
kg
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
0.320
0.320
0.320
0.360
(1) For 24...60 V 50/60 Hz - 20...60 V DC, use NF..ES-11 (see voltage code table).
NF..ES-11 not suitable for direct control by PLC-output.
Main dimensions
mm, inches
111 4.37"
45 1.77"
71 2.79"
10 0.39"
NF44ES, NF53ES, NF62ES, NF71ES, NF80ES
6/70 | ABB
1SBC101713S0201 - Rev. A
5.5 0.22"
45 1.77"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
NFZ..S 8-pole contactor relays - with spring terminals
AC / DC operated - low consumption
Description
Ordering details
Number of contacts
1st stack
Rated control circuit
voltage
Uc min. ... Uc max.
2nd stack
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
V 50/60 Hz
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
24...60
48...130
100...250
–
24...60
48...130
100...250
Type
V DC
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
12...20
20...60
48...130
100...250
NFZ44ES-20
NFZ44ES-21
NFZ44ES-22
NFZ44ES-23
NFZ53ES-20
NFZ53ES-21
NFZ53ES-22
NFZ53ES-23
NFZ62ES-20
NFZ62ES-21
NFZ62ES-22
NFZ62ES-23
NFZ71ES-20
NFZ71ES-21
NFZ71ES-22
NFZ71ES-23
NFZ80ES-20
NFZ80ES-21
NFZ80ES-22
NFZ80ES-23
Order code
Weight
1SBH136004R2044
1SBH136004R2144
1SBH136004R2244
1SBH136004R2344
1SBH136004R2053
1SBH136004R2153
1SBH136004R2253
1SBH136004R2353
1SBH136004R2062
1SBH136004R2162
1SBH136004R2262
1SBH136004R2362
1SBH136004R2071
1SBH136004R2171
1SBH136004R2271
1SBH136004R2371
1SBH136004R2080
1SBH136004R2180
1SBH136004R2280
1SBH136004R2380
Pkg
(1 pce)
kg
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
0.360
6
Note: Only NFZ..S contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to
the coil terminals: A1+ for the positive pole and A2- for the negative pole.
Main dimensions
mm, inches
111 4.37"
45 1.77"
71 2.79"
10 0.39"
1SBC101714S0201 - Rev. A
5.5 0.22"
45 1.77"
35 mm EN/IEC 60715
5.5
0.22"
11.5 0.45"
NFZ44ES
These contactors relays are of the block type design with:
–– 8 poles with a permanently fixed 4-pole auxiliary contact block. Contactor relays have mechanically linked auxiliary
contact elements (side-marked symbol)
–– control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range
(e.g. 100...250 V AC and DC)
-- can manage large control voltage variations
-- only 4 control voltage ranges covering 24...250 V 50/60 Hz and 12...250 V DC
-- allow direct control by PLC-output ≥ 24 V DC 500 mA
-- reduced panel energy consumption
-- very distinct closing and opening
-- can withstand short voltage dips and voltage sags (SEMI F47-0706 conditions of use on request).
–– built-in surge suppression
–– add-on auxiliary contact blocks for side mounting and a wide range of accessories.
80 3.15"
1SBC101107F0014
NFZ..S contactor relays are used for switching auxiliary and control circuits.
NFZ44ES, NFZ53ES, NFZ62ES, NFZ71ES, NFZ80ES
ABB | 6/71
NF..S contactor relays - with spring terminals
Main accessories
Contactor relays and main accessories (other accessories available)
NF..S contactor relay
TEF4S
Electronic timer
Top or bottom
mounted
coil terminal block
CA4..S
4-pole auxiliary
contact block
CAL4-11S
2-pole auxiliary
contact block
BX4-CA
Protective cover
6
BX4
Protective cover
CA4..S
1-pole auxiliary
contact block
Main accessory fitting details
Many configurations of accessories are possible depending on whether these are front-mounted or side-mounted.
Contactor relay
types
Front-mounted accessories
Auxiliary contact blocks
Main
poles
Electronic timer
Side-mounted accessories
Auxiliary contact blocks
TEF4S
2-pole CAL4-11S
Left side
1-pole CA4..S
4-pole CA4..S
Right side
Max. add-on N.C. auxiliary contacts: 3 N.C. max. on positions 1, 2, 3, 4 and 2 N.C. max. on positions 1 ±30°, 5
NF..
2 2 ES
3 1 ES
4 max.
2 max.
or 1
–
or 1
or 1
+
+
1
1
+
–
1
+
–
1
Max. add-on N.C. auxiliary contacts: 4 N.C. max. on positions 1, 2, 3, 4 and 3 N.C. max. on positions 1 ±30°, 5
NF..
4
5
6
7
8
4
3
2
1
0
ES
ES
ES
ES
ES
4 max.
2 max.
–
or 1
–
or 1
or 1
–
–
+
+
1
1
1
–
1SBC101666S0201
NF..
4 0 ES
6/72 | ABB
NF..S contactor relays - with spring terminals
Main accessories
Ordering details (1)
1SBC101110F0014
For contactor relays
Auxiliary Type
contacts
Order code
Pkg
qty
Weight
(1 pce)
kg
Front-mounted instantaneous auxiliary contact blocks
CA4-10S
1SBC101125F0014
NF..S
1
1
0
0
2
3
4
NF..S
CA4-22MS
0
0
1
1
2
1
0
CA4-10S
CA4-10S-T
CA4-01S
CA4-01S-T
CA4-22NS
CA4-31NS
CA4-40NS
1SBN010119R1010
1SBN010119T1010
1SBN010119R1001
1SBN010119T1001
1SBN010145R1222
1SBN010145R1231
1SBN010145R1240
1
10
1
10
1
1
1
0.016
0.016
0.016
0.016
0.060
0.060
0.060
1SBN010130R1011
1
0.045
Order code
Pkg
qty
Weight
(1 pce)
Side-mounted instantaneous auxiliary contact blocks
1SBC101113F0014
NF..S
1
For contactor relays Time delay Delay
range
type
1SBC101393F0014
selected by
switch
1SBC101135F0014
Rated control
circuit voltage
Uc
Auxiliary Type
contacts
6
kg
V 50/60 Hz or DC
Front-mounted electronic timer
NF..S
TEF4S-OFF
0.1...1 s
1...10 s
10...100 s
ON-delay
24...240
1
1
TEF4S-ON
1SBN020113R1000
1
0.065
OFF-delay 24...240
1
1
TEF4S-OFF 1SBN020115R1000
1
0.065
Type
Pkg
qty
Weight
(1 pce)
Ordering details (1)
BX4
Order code
kg
Additional coil terminal block
NF..S
LDC4S
1SBN070157T1000
10
0.010
BX4
BX4-CA
1SBN110108T1000
1SBN110109W1000
10
50
0.006
0.001
Protective covers
All 1-stack contactor relays
For 4-pole CA4..S auxiliary contact blocks
(1) See "Main accessory fitting details" table.
1SBC101706S0201
1SBC101136F0014
For contactors
LDC4S
1SBC101138F0014
CAL4-11S
Ordering details (1)
CAL4-11S
BX4-CA
1
ABB | 6/73
NF..S contactor relays - with spring terminals
Technical data
Contact utilization characteristics according to IEC
AC / DC operated
Contactor relay types
Standards
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional free-air thermal current Ith θ ≤ 40 °C
Ie / Rated operational current AC-15
NF..S
IEC 60947-1 / 60947-5-1 and EN 60947-1 / 60947-5-1
690 V
50/60 Hz
16 A
acc. to IEC 60947-5-1
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Rated making capacity AC-15
Rated breaking capacity AC-15
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
6
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
for 1.0 s
for 0.1 s
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts
Power dissipation per pole at 6 A
Max. electrical switching frequency
AC-15
DC-13
Mechanically linked contacts
(acc. to annex L of IEC 60947-5-1)
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
≥ 2 ms
0.1 W
1200 cycles/h
900 cycles/h
Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA4..S,
CAL4..S aux. contact blocks) are mechanically linked contacts
Contact utilization characteristics according to UL / CSA
AC / DC operated
NF..S
UL 508, CSA C22.2 N°14
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
1SBC101695S0201 - Rev. A
Contactor relay types
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
6/74 | ABB
NF..S contactor relays - with spring terminals
Technical data
General technical data
Contactor relay types
Rated insulation voltage Ui
acc. to IEC 60947-5-1
acc. to UL/CSA
Rated impulse withstand voltage Uimp.
Electromagnetic compatibility
Ambient air temperature close to contactor relay
Operation in free air
Storage
Climatic withstand
AC / DC operated
NF..S
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A
-40...+70 °C
-60...+80 °C
Category B according to IEC 60947-1 Annex Q
Maximum operating altitude (without derating)
Mechanical durability
Number of operating cycles
Max. switching frequency
Shock withstand
3000 m
20 millions operating cycles
6000 cycles/h
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
C1
A
A
B1
B2
C2
Shock direction
A
B1
B2
C1
C2
Vibration withstand
acc. to IEC 60068-2-6
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position
30 g
25 g closed position / 5 g open position
15 g
25 g
25 g
5...300 Hz
4 g closed position / 2 g open position
6
Magnet system characteristics
Contactor relay types
Coil operating limits
AC / DC operated
AC supply
acc. to IEC 60947-5-1
DC supply
NF..S
at θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
at θ ≤ 70 °C 0.85 x Uc min...Uc max.
at θ ≤ 60 °C 0.85 x Uc min...1.1 x Uc max.
at θ ≤ 70 °C (NF) 0.85 x Uc min...Uc max - (NFZ) 0.85 x Uc min...1.1 x Uc max.
AC control voltage Rated control circuit voltage Uc
24...500 V AC
Average pull-in value (NF) 50 VA - (NFZ) 16 VA
50/60 Hz
Coil consumption
Average holding value (NF) 2.2 VA / 2 W - (NFZ) 1.7 VA / 1.5 W
DC control voltage Rated control circuit voltage Uc
12...500 V DC
Average pull-in value (NF) 50 W - (NFZ) 12...16 W
Coil consumption
Average holding value (NF) 2 W - (NFZ) 1.7 W
PLC-output control
(NFZ) ≥ 500 mA 24 V DC
Drop-out voltage
≤ 60 % of Uc min.
Voltage sag immunity acc. to SEMI F47-0706
(NFZ) conditions of use on request
Dips withstand
(NFZ) 22 ms average for Uc ≥ 24 V 50/60 Hz or Uc ≥ 20 V DC
-20 °C ≤ θ ≤ +60 °C
Operating time
N.O. contact closing 40...95 ms
Between coil energization and:
N.C. contact opening 38...90 ms
N.O. contact opening 11...95 ms
Between coil de-energization and:
N.C. contact closing 13...98 ms
Mounting characteristics
Contactor relay types
Mounting positions
AC / DC operated
NF..S
Pos. 2
+30°
-30°
Pos. 4
Pos. 3
Pos. 1 ± 30°
Pos. 5
1SBC101695S0201 - Rev. A
Pos. 1
Max. add-on N.C. auxiliary contacts:
see accessory fitting details for a NF..S contactor relay
Mounting distances
Fixing
On rail according to IEC 60715, EN 60715
By screws (not supplied)
The contactor relays can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
ABB | 6/75
NF..S contactor relays - with spring terminals
Technical data
Connecting characteristics
Contactor relay types
Main terminals
AC / DC operated
NF..S
Spring terminals
Connection capacity (min. ... max.)
Pole and coil terminals
Rigid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL/CSA
Stripping length
Degree of protection
1x
2x
1x
2x
1x
2x
1 or 2 x
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...12
10 mm
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
All terminals
Screwdriver type
IP20
Flat Ø 3.5
1SBC101695S0201 - Rev. A
6
6/76 | ABB
NF..S contactor relays - with spring terminals
Terminal marking and positioning
Standard devices without addition of auxiliary contacts
13
A1
A2
21
31
13
43
A1
A2
21
33
43
13
NO NC NO NO
NO NC NC NO
A1
A2
23
33
43
13
NO NO NO NO
A1
A2
23
33
NO NO NO NO
51 61 71 81
NO NC NC NO
NO NC NO NO
NO NO NO NO
52 62 72 82
NO NO NO NO
14
14
14
14
32
A1
A2
44
NF..22ES
13
A1
A2
23
33
22
34
A1
A2
44
NF..31ES
43
13
NO NO NO NO
53 61 71 81
A1
A2
23
33
34
A2
44
NF..40ES
43
13
NO NO NO NO
53 61 71 83
NO NC NC NC
24
A1
A1
A2
23
33
34
A2
43
13
A1
A2
23
33
54 62 74 84
NO NO NO NO
54 64 74 84
NO NO NO NO
14
14
14
14
34
A2
44
NF..53ES
24
34
A1
A2
44
24
34
A1
A2
44
NF..71ES
NF..62ES
24
34
A1
A2
A2
NO
14
NC
22
NC
32
NO
44
A1
13
NO
21
NC
33
NO
43
NO
A2
NO
14
NC
22
NO
34
NO
44
NF..31ES
A1
13
NO
23
NO
33
NO
43
NO
A2
NO
14
NO
24
NO
34
NO
44
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
NC
72
NC
82
NF..44ES
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
81
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NC
82
NF..53ES
NO NO NO NO
54 62 72 84
NO NO NO NO
24
43
NO
A1
13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NC
72
NO
84
43
54 62 72 82
NO NO NO NO
A1
31
NC
NF..40ES
NO NO NO NO
53 63 73 83
NO NC NO NO
21
NC
44
NF..44ES
NO NO NO NO
53 61 73 83
NO NC NC NO
24
A1
13
NO
NF..22ES
NC NC NC NC
22
A1
43
NF..62ES
6
A1 13
NO
23
NO
33
NO
43
NO
53
NO
61
NC
73
NO
83
NO
A1
13
NO
23
NO
33
NO
43
NO
53
NO
63
NO
73
NO
83
NO
NO
14
NO
24
NO
34
NO
44
NO
54
NC
62
NO
74
NO
84
A2
NO
14
NO
24
NO
34
NO
44
NO
54
NO
64
NO
74
NO
84
44
A2
NF..71ES
NF..80ES
NF..80ES
Other possible contact combinations with auxiliary contacts added by the user
A1
A2
21
33
43
13
A2
21
33
13
43
NO NC NO NO
5-
NO NC NO NO
53
NO
A1
=
+
54
NO NC NO NO
5NO NC NO NO
14
14
22
34
A1
A2
44
22
34
A1
A2
A1
A2
23
33
+
33
14
14
CA4-10S
A1
A2
23
33
43
NC
24
34
A2
44
13
A1
A2
23
33
13
43
24
34
A1
A2
A1
A2
23
33
=
+
14X
14X
14
14
14
44
Combination 51
=
CAL4-11S +
24
34
A1
A2
NF..40ES
44
24
34
A1
A2
44
-2
24
34
A1
A2
Combination 62 = NF..40ES
61
71
83
NO NC NC NO
54
NO NO NO NO
34
NC
+
-2
53
54 62 72 84
NO NO NO NO
A2
21
NC
33
NO
43
NO
53
NO
A2
NO
14
NC
22
NO
34
NO
44
NO
54
Combination 41E
A1
13
NO
23
NO
33
NO
43
NO
51
NC
61
NC
A2
NO
14
NO
24
NO
34
NO
44
NC
52
NC
62
Combination 42E
A1
13
NO
23
NO
33
NO
43
NO
13X
NO
21X
NC
A2
NO
14
NO
24
NO
34
NO
44
NO
14X
NC
22X
43
NO NO NO NO
24
NC
+ CA4-01S+CA4-01S
22X
NO
A1
-1
NO NO NO NO
NO NO NO NO
53 61 71 83
13
NO
44
22X
NO NO NO NO NO
14
-1
+
Combination 42 = NF..40ES
NO NC NC NO
+
NO NO NO NO
5- 6=
A1
A1
43
5- 6NO NO NO NO
NO NO NO NO
NC
A2
23
52 62
NO NO NO NO
NO
21X
=
A1
-4
NO NO NO NO NO
21X
NC
13
NC NC
13
NC
43
NO
13X
13
33
NO NO NO NO
51 61
43
13X
A2
23
-3
44
Combination 41 = NF..31ES
A1
62
72
84
Combination 51E
A1
13
NO
23
NO
33
NO
43
NO
53 61
NO NC
71
NC
83
NO
A2
NO
14
NO
24
NO
34
NO
44
NO NC
54 62
NC
72
NO
84
44
+
CA4-22NS
Combination 62E
Note: Only NFZ contactor relays with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole.
ABB | 6/77
1SBC101694S0201
13
NF..S contactor relays - with spring terminals
mm, inches
ø 4.2 0.17"
5.5 0.22"
35 mm EN/IEC 60715
35 mm EN/IEC 60715
6 0.24"
80 3.15"
11.5 0.45"
35 1.38"
71 2.80"
5.5 0.22"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
45 1.77"
5.5
0.22"
80 3.15"
77 3.03"
71 2.79"
5 0.20"
77 3.03"
45 1.77"
60 2.36"
Main dimensions
10 0.39"
10 0.39"
5 0.20"
NF..22ES, NF..31ES, NF..40ES
6
111 4.37"
45 1.77"
71 2.79"
77 3.03"
10 0.39"
12 0.47"
71 2.79"
45 1.77"
35 mm EN/IEC 60715
80 3.15"
5.5 0.22"
11.5 0.45"
5.5
0.22"
45 1.77"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
5.5 0.22"
10 0.39"
NF..22ES, NF..31ES, NF..40ES
+ CA4..S 1-pole auxiliary contact block
NF..22ES, NF..31ES, NF..40ES
+ CAL4-11S 2-pole auxiliary contact block
111 4.37"
111 4.37"
45 1.77"
10 0.39"
71 2.79"
NF..22ES, NF..31ES, NF..40ES
+ CA4..S 4-pole auxiliary contact block
Note: Contactor relay lateral distance to grounded component 2 mm 0.08" min.
6/78 | ABB
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5 0.22"
10 0.39"
5.5
0.22"
45 1.77"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
5.5
0.22"
5.5 0.22"
NF..44ES, NF..53ES, NF..62ES, NF..71ES, NF..80ES
1SBC101668S0201
71 2.79"
45 1.77"
45 1.77"
NF..S contactor relays - with spring terminals
mm, inches
133.5 5.26"
77 3.03"
10 0.39"
71 2.80"
35 1.38"
ø 4.2 0.17"
5.5 0.22"
2x
M4 8-32 UNC
70 2.76"
5.5 0.22"
60 2.36"
5.5 0.22"
5 0.20"
1.1 0.04"
35 mm EN/IEC 60715
80 3.15"
71 2.79"
45 1.77"
5.5
0.22"
6 0.24"
35 mm EN/IEC 60715
11.5 0.45"
80 3.15"
45 1.77"
41.3 1.63"
Main dimensions
10 0.39"
5 0.20"
NF..22ES, NF..31ES, NF..40ES
+ TEF4S
1SBC101704S0201
6
Note: Contactor relay lateral distance to grounded component 2 mm 0.08" min.
ABB | 6/79
Auxiliary contact blocks - with spring terminals
1SBC101110F0014
Description
The auxiliary contact blocks are used for the operation of auxiliary and control circuits for standard industrial
environments.
Types of auxiliary contact blocks for front mounting:
–– CA4..S 1 or 4-pole block, with instantaneous N.O., N.C. contacts
–– CAT4..S 2-pole block, front-mounted, instantaneous N.O. + N.C. contacts with A1 / A2 coil terminal connection on front face
–– CAL4..S 2-pole block, with instantaneous N.O. + N.C. contacts clipped onto the right and/or left side of
the contactors.
1SBC101113F0014
CA4-10S
CAL4-11S
Select the type of 2 or 4-pole auxiliary contact blocks CAT4 or CA4 (-..ES, -..MS, -..US or -..NS) according
to the device type for compliance with the standard requirements (see terminal and marking positioning).
The auxiliary contact blocks are equipped with spring terminals protected against accidental direct contact
and bear the corresponding function marking.
Ordering details (1)
For contactors
Auxiliary contacts
Type
Order code
Pkg
qty
6
Weight
(1 pce)
1SBC101125F0014
kg
Front-mounted instantaneous auxiliary contact blocks
AF09..S ... AF38..S
4-pole NF..S
CA4-22MS
AF09 ... AF16..-30-10S
1SBC101117F0014
AF26..S
4-pole NF..S
1
1
0
0
2
3
2
3
4
2
3
4
0
0
1
1
2
1
2
1
0
2
1
0
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
CA4-10S
CA4-10S-T
CA4-01S
CA4-01S-T
CA4-22MS
CA4-31MS
CA4-22ES
CA4-31ES
CA4-40ES
CA4-22NS
CA4-31NS
CA4-40NS
1SBN010119R1010
1SBN010119T1010
1SBN010119R1001
1SBN010119T1001
1SBN010145R1122
1SBN010145R1131
1SBN010145R1022
1SBN010145R1031
1SBN010145R1040
1SBN010145R1222
1SBN010145R1231
1SBN010145R1240
1
10
1
10
1
1
1
1
1
1
1
1
0.016
0.016
0.016
0.016
0.060
0.060
0.060
0.060
0.060
0.060
0.060
0.060
1SBN010130R1011
1
0.045
1
1
1
0.045
0.045
0.045
CAT4-11ES
Side-mounted instantaneous auxiliary contact blocks
AF09..S ... AF26..S
NF..S
1
1
–
–
CAL4-11S
Front-mounted instantaneous auxiliary contact and A1/A2 coil terminal blocks
AF09 ... AF16..-30-10S
AF26..S
AF09 ... AF16..-30-01S
1
1
1
1
1
1
–
–
–
–
–
–
CAT4-11MS
CAT4-11ES
CAT4-11US
1SBN010153R1111
1SBN010153R1011
1SBN010153R1311
1SBC101705S0201
(1) For each contactor or contactor relay type, refer to "Accessory fitting details" table.
Note: CAT4..S not fittable on AF..Z contactors with DC control voltage 12…20 V DC.
6/80 | ABB
Auxiliary contact blocks - with spring terminals
Technical data
1-pole CA4..S, 4-pole CA4..S, 2-pole CAT4..S, 2-pole CAL4..S
Types
Contact utilization characteristics according to IEC
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
24...690 V
16 A
50/60 Hz
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp.
Rated operational voltage Ue max.
Conventional thermal current Ith - θ ≤ 40 °C
Rated frequency (without derating)
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
24-127 V 50/60 Hz
220-240 V 50/60 Hz
400-440 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
Making capacity
Breaking capacity
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 6 A
Mechanical durability
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
24 V DC
48 V DC
72 V DC
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
for 1.0 s
for 0.1 s
AC-15
DC-13
Mechanically linked contacts acc. to annex L of IEC 60947-5-1
Mirror contacts acc. to annex F of IEC 60947-4-1
6A
4A
3A
2A
2A
10 x Ie AC-15 acc. to IEC 60947-5-1
10 x Ie AC-15 acc. to IEC 60947-5-1
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10-7
0.1 W
10 millions operating cycles
3600 cycles/h
1200 cycles/h
900 cycles/h
Additional N.O. or N.C. auxiliary contacts (CA4..S, CAL4..S, CAT4..S) are mechanically linked contacts
Additional N.C. auxiliary contacts (CA4..S, CAL4..S, CAT4..S) are mirror contacts
6
Contact utilization characteristics according to UL / CSA
UL 508, CSA C22.2 N°14
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
Standards
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Connecting characteristics
Flexible with ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL/CSA
Stripping length
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screwdriver type
1x
2x
1x
2x
1x
2x
1 or 2 x
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
AWG 18...14
10 mm
IP20
Flat Ø 3.5
1SBC101717S0201
Connection capacity (min. ... max.)
Rigid solid
ABB | 6/81
Auxiliary contact blocks for AF09..S ... AF26..S contactors and
NF..S contactor relays - with spring terminals
Electrical durability
Electrical durability for AC-15 utilization category
AC-15 utilization category according to IEC 60947-5-1 / EN 60947-5-1:
–– making current: 10 x Ie with cos ϕ = 0.7 and Ue
– – breaking current: Ie with cos ϕ = 0.4 and Ue.
These curves represent the electrical durability of the built-in or add-on auxiliary contacts in relation to the breaking current.
The curves have been drawn for resistive and inductive loads up to 690 V, 40...60 Hz.
30
20
– – AF09..S ... AF26..S contactor built-in auxiliary contacts
– – 1-pole and 4-pole CA4..S, 2-pole CAT4..S,
2-pole CAL4..S add-on auxiliary contacts.
10
3
Example:
Breaking current = 1 A
On the opposite curve at intersection "O" 1 A the
corresponding value for the electrical durability is approximately 2 millions operating cycles.
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2
3 4 5 6
10
Breaking current (A)
30
20
NF..S contactor relays.
(For add on auxiliary contacts see curve above).
10
Million operating cycles
5
3
2
1
0.5
0.3
0.2
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2
3 4 5 6
10
Breaking current (A)
Electrical durability for DC-13 utilization category
DC-13 utilization category according to IEC 60947-5-1 / EN 60947-5-1: making and breaking current Ie and Ue.
100
70
50
6
1.10 cycles
6
3.10 cycles
– – AF09..S ... AF26..S contactor built-in auxiliary contacts
1-pole and 4-pole CA4..S, 2-pole CAT4..S,
2-pole CAL4..S add-on auxiliary contacts,
–– NF..S contactor relays.
20
6
10.10 cycles
10
5
2
1
10
20 24
50
72
100
200 250
Voltage (V)
6/82 | ABB
500
Example:
Control of DC electro-magnet:
Ue voltage = 72 V DC and breaking power = 70 W.
On the opposite curve at intersection "O" 72 V / 70 W the
corresponding value for the electrical durability is approximately 2 millions operating cycles.
1SBC101937S0201
Breaking power (W)
6
Million operating cycles
5
Add-on auxiliary contacts - with spring terminals
Terminal marking and positioning
1-pole auxiliary contacts
-1
-3
NO
NC
-4
-2
CA4-01S
CA4-10S
2-pole auxiliary contacts
31X
43X
21
32X /
13
-3
-1
NC
NO
22
14
CAT4-11MS
6
21
NC
NO
34
22
44X /
CAL4-11S
(Right side-mounted)
33
NO
NC
NO
21X
44X
22X /
CAL4-11S
(Left side-mounted)
43X /
NC
13X
32X
14X /
31X /
NC
22X
21X /
NO
14X
13X /
-2
-4
CAT4-11ES
CAT4-11US
4-pole auxiliary contacts
54
63
NO
73
NO
64
74
83
NO
84
53
54
61
73
NC NO
62
74
83
NO
84
53
54
61
71
NC
NC
62
72
CA4-22NS
33
NO
24
34
43
53
NO
NO
44
54
13
NO
14
21
NC
22
33
NO
34
83
NO
84
13
NO
14
21
31
NC
NC
22
32
CA4-22ES
63
NO
73
NO
64
74
83
NO
84
CA4-40NS
43
NO
44
CA4-31ES
CA4-31NS
NO
14
23
NO
CA4-40ES
CA4-40NS
NO
13
NO
21
NC
22
33
NO
34
43
NO
44
53
NO
54
CA4-31MS
43
NO
44
21
31
NC
NC
22
32
43
NO
44
CA4-22MS
53
NO
54
61
73
NC NO
62
74
83
NO
84
CA4-31NS
53
NO
54
53
NO
54
61
71
NC
NC
62
72
83
NO
84
CA4-22NS
1SBC101681S0201
53
NO
ABB | 6/83
Electronic timers - with spring terminals
1SBC101394F0014
Description
TEF4S-ON
TEF4S frontal electronic timers are used for realizing timing function and are available in ON-delay and
OFF-delay versions.
Compact solution in cabinet compared to separate timers
TEF4S electronic timers are front-mounted and locked on AF..S contactors or NF..S contactor relays.
A mechanical indicator allows to show the state of the contactor.
Safe and cost-reduced wiring
TEF4S electronic timers are supplied by a direct plug-in parallel connection to the coil terminals A1 - A2 of
the contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection against
surges in the contactor coil.
Available for a wide control voltage range 24...240 V AC/DC
TEF4S-ON or TEF4S-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges, independently of the control system. The time delay ranges are selected by a switch and the time delay can be
adjusted by means of a rotary switch. The timing function is activated by closing or opening the device on
which the timer is mounted. The OFF-delay version operates without additional control supply.
Ordering details
1SBC101393F0014
6
For contactors,
contactor relays
Time delay
range
Delay
type
selected by
switch
Rated control
circuit voltage
Uc
Auxiliary Type
contacts
Order code
Pkg
(1 pce)
24...240
1
1
TEF4S-ON
1SBN020113R1000
kg
0.065
OFF-delay 24...240
1
1
TEF4S-OFF 1SBN020115R1000
0.065
V 50/60 Hz or DC
AF09..S ... AF26..S
NF..S
0.1...1 s
1...10 s
10...100 s
ON-delay
1SBC101671S0201
TEF4S-OFF
Weight
6/84 | ABB
Electronic timers - with spring terminals
Technical data
Contact utilization characteristics according to IEC
Types
Standards
Rated insulation voltage Ui acc. to IEC 60947-5-1
Rated impulse withstand voltage Uimp
Rated operational voltage Ue max.
Rated frequency (without derating)
Conventional thermal current Ith - θ ≤ 40 °C
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1
TEF4S-ON
IEC 60947-5-1 and EN 60947-5-1
400 V
4 kV
240 V
50 / 60 Hz
5 A
24-127 V 50/60 Hz
220-240 V 50/60 Hz
Making capacity acc. to IEC 60947-5-1
Breaking capacity acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
TEF4S-OFF
3 A
1.5 A
10 x Ie AC-15
10 x Ie AC-15
1 A / 24 W
6 A
for 1.0 s 8 A
for 0.1 s 8 A
12 V / 3 mA
24 V DC 10-7
0.1 W
ON-delay
24 V DC
acc. to IEC 60947-5-1
Short-circuit protection device gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Power dissipation per pole at 3 A
Function diagram
6
OFF-delay
150 ms
min.
Uc (A1 - A2)
1s
min.
Uc (A1 - A2)
100 ms
min.
100 ms
min.
N.O. (67 - 68)
N.O. (67 - 68)
N.C. (55 - 56)
N.C. (55 - 56)
t
t
Bistable relay inside.
Before use, once apply Uc then switch it off in order to initialize position of the contacts.
Control circuit voltage
AC control voltage
50/60 Hz
DC control voltage
Rated control circuit voltage Uc
Average consumption
Rated control circuit voltage Uc
Average consumption
Rated frequency limits
Supply voltage range
Overvoltage protection
Time delay range (t) selected by switch
24...240 V AC
1.5 mA RMS
24...240 V DC
1.5 mA
50 / 60 Hz
0.85...1.1 x Uc (at θ ≤ 70 °C)
Varistor included
1 mA RMS
1 mA
0.1...1 s
1...10 s
10...100 s
On-load reiteration accuracy under constant conditions
Minimum ON period
Recovery time
Ambient air temperature Operation
Storage
Climatic withstand
Maximum operating altitude
Mounting positions
Shock withstand
≤1%
0.1 s
1 s
0.15 s
0.1 s
-25 °C ... +70 °C
-40 °C ... +80 °C
Category B according to IEC 60947-1 Annex Q
2000 m
Mounting positions 1, 1 +/- 30°, 2, 3, 4, 5
1/2 sinusoidal shock for 11 ms: no change in contact position
Same as contactor or contactor relay
acc. to IEC 60068-2-27 and EN 60068-2-27
(Mounting position 1)
Vibration withstand
5...300 Hz
3 g closed position / 2 g open position
acc. to IEC 60068-2-6
Mechanical durability
5 millions operating cycles
3600 cycles/h
AC-15
DC-13
1800 cycles/h
1200 cycles/h
900 cycles/h
1SBC101672S0201
Number of operating cycles
Max. switching frequency
Max. electrical switching frequency
ABB | 6/85
Electronic timers - with spring terminals
Technical data
Contact utilization characteristics according to UL / CSA
Types
Standards
Rated insulation voltage Ui acc. to UL / CSA
Max. operational voltage
Pilot duty
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
TEF4S-ON
UL 508, CSA C22.2 N°14
300 V
240 V
B300, R300
5A
3600 VA
360 VA
1A
28 VA
TEF4S-OFF
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Connection capacity acc. to UL / CSA
Stripping length
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screwdriver type
Terminal Marking
1...2.5 mm²
1...2.5 mm²
0.75...2.5 mm²
0.75...2.5 mm²
0.75...1.5 mm²
0.75...1.5 mm²
AWG 18...14
10 mm
IP20
Flat Ø 3.5
A1
55 NC
67 NO
KM1
A2
A1
55 NC
67 NO
56 NC
68 NO
KM1
56 NC
68 NO
A2
1SBC101672S0201
6
1x
2x
1x
2x
1x
2x
1 or 2 x
6/86 | ABB
1SBC101128F0014
Other accessories
Ordering details
For contactors
Type
Order code
Pkg
qty
Weight
(1 pce)
kg
VM4
1SBC101127F0014
Mechanical interlock unit
VM4 mechanical interlock unit for the interlocking of two AF contactors.
When mounted between two contactors without additional width, the VM4 mechanical interlock unit
prevents one of the contactors from closing as long as the other contactor is closed.
The mechanical interlock unit includes 2 fixing clips (BB4).
BB4
1SBC101135F0014
AF09..S ... AF26..S
VM4
1SBN030105T1000
10
0.005
BB4
1SBN110120W1000
50
0.002
Fixing clips
AF09..S ... AF26..S
LDC4S
Additional coil terminal block - with spring terminals
1SBC101136F0014
Additional coil terminal block for a bottom access to the coil terminals of contactors or contactor relays.
AF09..S ... AF26..S and NF..S
LDC4S
1SBN070157T1000
10
6
0.010
Protective covers
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices
against accidental contact.
BX4
1SBC101138F0014
All 1-stack contactors and contactor relays
For 4-pole CA4 and 2-pole CAT4 auxiliary contact blocks
BX4
BX4-CA
1SBN110108T1000
1SBN110109W1000
10
50
0.006
0.001
Mounting piece
Mounting piece for replacement of A / AL26 ... A / AL40 contactors fixed by screws by AF contactors
in 45 mm width.
1SBC101383F0014
BX4-CA
AF09..S ... AF26..S
BP38-4
1SBN112303T1000
10
0.003
Function markers
Box of 16 blank cards (16 markers by card) printable on HTP500 thermal transfer printer and AMS 500
marking table to identify your contactors, overload relays or manual motor starters.
Marker dimensions: 7 x 20 mm (.276" x .787").
BP38-4
1SNC160101F0014
Box of 16 blank cards
AMS 500 support plate for 8 BA4
HTP500 support plate
BA4
SPRC 1
HTP500-BA4
1SNA235156R2700
1SNA360010R1500
1SNA235712R2400
16
1
1
0.011
0.220
0.290
1SBN110122T1000
10
0.007
Test block
BDT4 test block is suitable for switching on contactor off-load.
Marking on the block indicates the contactor type to fit with.
BA4
BDT4
1SBC100041V0014
AF..S, NF..S
Main dimensions
mm, inches
45 1.77"
44.8 1.76"
1SBC101708S0201 - Rev. A
ø 4.2 0.17"
M4 8-32 UNC
5 0.20"
70 2.76"
80 3.15"
90 3.54"
6
0.24"
28 1.10"
BDT4
5 0.20"
54 2.13"
BX4
BP38-4
ABB | 6/87
Voltage code table
The below tables indicate the available coil voltages and corresponding digits for order codes.
3-pole contactors - with spring terminals
Auxiliary contacts
N.O. N.C.
Type
Order code
1SBL137004R 12 10
AF09 - 30 - 10 S - 12
AC coil code
50/60 Hz
11 24...60 V
12 48...130 V
13 100...250 V
14 250...500 V
N.O. N.C.
Main contacts
Contactor with spring terminal
Contactor type
AC / DC operated
AF..
DC coil code
20...60 V
48...130 V
100...250 V
250...500 V
6 3-pole contactors - low consumption - with spring terminals
Low coil consumption
Auxiliary contacts
N.O. N.C.
Type
Order code
AF09 Z - 30 - 10 S - 21
1SBL136004R 21 10
N.O. N.C.
Main contacts
Contactor with spring terminal
AF..
Contactor type
AC / DC operated
AC coil code
50/60 Hz
20 –
21 24...60 V
22 48...130 V
23 100...250 V
DC coil code
AC coil code
50/60 Hz
11 24...60 V
12 48...130 V
13 100...250 V
14 250...500 V
DC coil code
12...20 V
20...60 V
48...130 V
100...250 V
Contactor relays - with spring terminals
Contactor with spring terminal
Type
NF 22 E
S - 12
Order code
1SBH137004R 12 22
N.O. N.C.
Number contacts
NF
Contactor type
AC / DC operated
20...60 V
48...130 V
100...250 V
250...500 V
Contactor relays - low consumption - with spring terminals
Low coil consumption
NF Z 22 E
N.O. N.C.
Number contacts
NF
Contactor type
AC / DC operated
6/88 | ABB
S - 21
Order code
1SBH136004R 21 22
AC coil code
50/60 Hz
20 –
21 24...60 V
22 48...130 V
23 100...250 V
DC coil code
12...20 V
20...60 V
48...130 V
100...250 V
1SBC101729S0201
Contactor with spring terminal
Type
Notes
N13
6
ABB | 6/89
Summary_7
7
7/0 | ABB
Overload relays
Overview
Thermal and electronic overload relays
7/2
Thermal overload relays
T16 (0.10 … 16 A)
Ordering details
Technical data
7/4
7/5
TF42 (0.10 … 38 A)
Ordering details
Technical data
7/8
7/9
TF65 (22 ... 67 A)
Ordering details
Technical data
7/12
7/13
TF96 (40 ... 96 A)
Ordering details
Technical data
7/16
7/17
TF140DU (66 … 142 A)
Ordering details
Technical data
7/20
7/21
TA200DU (66 … 200 A)
Ordering details
7/24
Technical data
7/25
7
Electronic overload relays
E16DU, E45DU, E80DU, E140DU (0.10 ... 140 A)
Ordering details
Technical data
Accessories
7/28
7/29
7/32
EF19, EF45 (0.10 ... 45 A)
Ordering details
Technical data
7/33
7/34
EF65, EF96, EF146 (20 ... 150 A)
Ordering details
Technical data
7/37
7/38
EF205, EF370 (63 ... 380 A)
Ordering details
Technical data
7/41
7/42
EF460, EF750 (150 ... 800 A)
Ordering details
Technical data
7/45
7/46
E1250DU (375 ... 1250 A)
Ordering details
7/48
Technical data
7/49
General accessories
WRB, WRH
7/51
Summary_7
Ordering details
ABB | 7/1
Thermal and electronic overload relays
Thermal overload
relays
7
IEC: rated operational power AC-3
400 V
0.03 … 4.0 kW
0.03 … 4.0 kW
4.0 … 18.5 kW
18.5 … 30 kW
UL/CSA: 3-phase hp-ratings
480 V
1/2 … 5 hp
1/2 … 10 hp
5 … 20 hp
30 … 60 hp
Fitting to contactors
B6, B7
AS09 … AS16
AF09 ... AF38
AF40, AF52, AF65
Type
T16
T16
TF42
TF65
Current range
0.10 … 16 A
0.10 … 16 A
0.10 … 38 A
22 … 67 A
Trip class
10
10
10
10
Single mounting kit
DB16
DB16
DB42
-
0.03 … 4.0 kW
4 … 7.5 kW
4.0 … 18.5 kW
18.5 … 30 kW
Electronic overload
relays
with integrated CT
IEC: rated operational power AC-3
400 V
UL/CSA: 3-phase hp-ratings
480 V
1 … 5 hp
5 … 10 hp
5 … 20 hp
30 … 60 hp
Fitting to contactors
B6, B7
AF09 … AF16
AF26 ... AF38
AF40, AF52, AF65
Type
E16DU
EF19
EF45
EF65
Current range
0.10 … 18.9 A
0.10 … 18.9 A
9 … 45 A
20 … 70 A
DB16E
DB19EF
Trip class
10E, 20E, 30E selectable
Single mounting kit
-
Electronic overload
relays
with external separate CT
IEC: rated operational power AC-3
400 V
UL/CSA: 3-phase hp-ratings
480 V
200 … 250 kW
315 … 400 kW
350 … 400 hp
500 … 600 hp
Fitting to contactors
AF400, AF460
AF580, AF750, AF1250
Type
EF460
EF750
Current range
150 … 500 A
250 … 800 A
Trip class
7/2 | ABB
10E, 20E, 30E selectable
-
37 … 45 kW
55 … 75 kW
90 … 110 kW
60 hp
75 … 100 hp
125 … 150 hp
AF80, AF96
AF116, AF140
AF190, AF205
TF96
TF140DU
TA200DU
40 … 96 A
66 … 142 A
66 … 200 A
10
10A
10A
-
-
DB200
7
37 … 45 kW
55 … 75 kW
90 … 110 kW
132 … 200 kW
60 hp
75 … 100 hp
125 … 150 hp
200 … 350 hp
AF80, AF96
AF116, AF140, AF146
AF190, AF205
AF265, AF305, AF370
EF96
EF146
EF205
EF370
36 … 100 A
54 … 150 A
63 … 210 A
115 … 380 A
-
-
10E, 20E, 30E selectable
-
-
475 … 560 kW
800 … 900 hp
AF1350, AF1650
2CDC106062C0201
E1250DU
375 … 1250 A
10E, 20E, 30E selectable
ABB | 7/3
T16 thermal overload relays
0.10 to 16.0 A
2CDC231009F0013
Description
T16
The T16 thermal overload relays are economic electromechanical protection devices for the main circuit.
They offer reliable protection for motors in the event of overload or phase failure. The devices have trip
class 10.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows
through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over
current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a
change of the contacts switching position (95-96 / 97-98).
– – Manual or automatic reset selectable
– – Phase loss sensitive acc. to IEC/EN 60947-4-1
– – TEST and STOP function – Trip indication on the front
– – Temperature compensation
– – Suitable for three- and single-phase applications
Ordering details
2CDC231025F0013
Setting range
1SFC151402F0001
T16 + DB16
KPR-101L
2CDC231002F0011
DB16
Trip class
Type
Order code
0.5 A, fuse type T
1.0 A, fuse type T
1.0 A, fuse type T
1.0 A, fuse type T
2.0 A, fuse type gG
2.0 A, fuse type gG
4.0 A, fuse type gG
6.0 A, fuse type gG
6.0 A, fuse type gG
10.0 A, fuse type gG
10.0 A, fuse type gG
10.0 A, fuse type gG
20.0 A, fuse type gG
20.0 A, fuse type gG
35.0 A, fuse type gG
35.0 A, fuse type gG
40.0 A, fuse type gG
40.0 A, fuse type gG
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
T16-0.13
T16-0.17
T16-0.23
T16-0.31
T16-0.41
T16-0.55
T16-0.74
T16-1.0
T16-1.3
T16-1.7
T16-2.3
T16-3.1
T16-4.2
T16-5.7
T16-7.6
T16-10
T16-13
T16-16
1SAZ711201R1005
1SAZ711201R1008
1SAZ711201R1009
1SAZ711201R1013
1SAZ711201R1014
1SAZ711201R1017
1SAZ711201R1021
1SAZ711201R1023
1SAZ711201R1025
1SAZ711201R1028
1SAZ711201R1031
1SAZ711201R1033
1SAZ711201R1035
1SAZ711201R1038
1SAZ711201R1040
1SAZ711201R1043
1SAZ711201R1045
1SAZ711201R1047
Weight
(1 pce)
kg
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.104
0.104
0.104
Ordering details accessories
Suitable for
Description
Type
Order code
T16
T16
Single mounting kit
Reset push button*
DB16
KPR-101L
1SAZ701901R0001
1SFA616162R1014
Weight
(1 pce)
kg
0.032
0.027
*Note: for more information see cataloge 1SFC151004C0201
Main dimensions
8.6
9.1
0.34"
0.36"
36.9
0.05"
1.45"
2.4
0.09"
3.02"
1.2
mm, inches
14.4
45
T16
7/4 | ABB
12.35
0.36"
0.32"
1.77"
0.57"
0.49"
35.6
1.4"
48.2
1.9"
53.5
2.11"
2CDC106036C0201
9.1
8.1
2CDC232008F0008
76.7
7
A
0.10 ... 0.13
0.13 ... 0.17
0.17 ... 0.23
0.23 ... 0.31
0.31 ... 0.41
0.41 ... 0.55
0.55 ... 0.74
0.74 ... 1.00
1.00 ... 1.30
1.30 ... 1.70
1.70 ... 2.30
2.30 ... 3.10
3.10 ... 4.20
4.20 ... 5.70
5.70 ... 7.60
7.60 ... 10.0
10.0 ... 13.0
13.0 ... 16.0
Short-circuit
protective device
T16 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
T16
IEC/EN 60947–4–1, IEC/EN 60947-5-1, IEC/EN 60947-1
690 V AC
- V DC
50/60 Hz
10
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
6 kV
690 V AC
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
T16
600 V
N.C., 95-96 6 A
N.O., 97-98 4 A
DC, 50/60 Hz
1 N.O. + 1 N.C.
3.00
0.75
3.00
0.75
0.75
0.75
N.C., 95-96 0.75
N.O., 97-98 0.75
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
7
A
A
A
A
A
A
A
A
1.25 A
1.25 A
0.55 A
0.55 A
0.55 A
0.55 A
0.27 A
0.27 A
17 V / 3 mA
N.C., 95-96 6 A, fuse type gG
N.O., 97-98 4 A, fuse type gG
6 kV
690 V
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Technical diagram – Intermittent periodic duty
(Op/h)
140
120
s
0.5
80
ta
ta =
.5
3s
s
5s
0
0
20
40
60
80
duty ratio
100 (%)
2CDC106036C0201
20
=1
s
ta =
1
ta
40
2CDC232004F0214
60
=
switching frequency
ta =
100
ta: Motor starting time
ABB | 7/5
T16 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
T16
UL 508, CSA 22.2 No. 14
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Conventional thermal current
T16
B600, Q300
D300, Q300
5A
2.5 A
Full load amps and short-circuit protective device
Type
T16-0.13
T16-0.17
T16-0.23
T16-0.31
T16-0.41
T16-0.55
T16-0.74
T16-1.0
T16-1.3
T16-1.7
T16-2.3
T16-3.1
T16-4.2
T16-5.7
T16-7.6
T16-10
T16-13
T16-16
0.13
0.17
0.23
0.31
0.41
0.55
0.74
1.00
1.30
1.70
2.30
3.10
4.20
5.70
7.60
10.0
13.0
16.0
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Short-circuit protective device
480 / 600 V AC
Short circuit rating RMS
Fuse type
symmetrical
18 kA
1 A, K5
18 kA
1 A, K5
18 kA
1 A, K5
18 kA
3 A, K5
18 kA
3 A, K5
18 kA
3 A, K5
18 kA
3 A, K5
18 kA
6 A, K5
18 kA
6 A, K5
18 kA
6 A, K5
18 kA
10 A, K5
18 kA
10 A, K5
18 kA
15 A, K5
18 kA
20 A, K5
18 kA
25 A, K5
18 kA
35 A, K5
18 kA
40 A, K5
18 kA
60 A, K5
480 / 600 V AC
Short circuit rating RMS
symmetrical
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
Fuse type
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
45
45
45
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
A,
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
Class
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
2CDC106036C0201
7
Full load amps (FLA)
7/6 | ABB
T16 thermal overload relays
Technical data
General technical data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
T16
3
Yes
Open - compensated
Open
-25 ... +60 °C
-25 ... +60 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
3g / 3 ... 150 Hz
Position 1-5
Mount on the contactor and tighten the screws of the main circuit terminals or with single
mounting kit on DIN rail (35 mm)
IP20
IP10
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Housing
Main circuit terminals
Degree of protection
Electrical connection
Main circuit
Type
Connecting capacity
T16
Rigid
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1x
2x
1 x or 2 x
1 x or 2 x
1 x or 2 x
Stripping length
Tightening torque
Recommended screw driver
7
1)
Only connect two different "conductor/wire" cross-sections, if they are within the indicated ranges
Auxiliary circuit
Type
Connecting capacity
T16
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 x or 2 x
1 x or 2 x
1x
2x
1 x or 2 x
1 x or 2 x
1 x or 2 x
0.75 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
0.75 ... 1 mm² or 1 ... 2.5 mm²
AWG 18-12
AWG 18-12
9 mm
1.1 ... 1.5 Nm / 9 … 13 Ib.in
M3 (Pozidriv 2)
2CDC106036C0201
1)
0.75 ... 4 mm²
0.75 ... 1.5 mm² or 1.5 ... 4 mm²
0.75 ... 4 mm²
AWG 18-10
AWG 18-10
12 mm
1.1 ... 1.5 Nm / 9 … 13 Ib.in
M4 (Pozidriv 2)
ABB | 7/7
TF42 thermal overload relays
0.10 to 38.0 A
2CDC231006F0013
Description
TF42
The TF42 thermal overload relays are economic electromechanical protection devices for the main circuit.
They offer reliable protection for motors in the event of overload or phase failure. The devices have trip
class 10.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows
through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over
current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a
change of the contacts switching position (95-96 / 97-98).
– – Manual or automatic reset selectable
– – Phase loss sensitive acc. to IEC/EN 60947-4-1
– – TEST and STOP function – Trip indication on the front
– – Temperature compensation
– – Suitable for three- and single-phase applications
Ordering details
2CDC231001F0011
Setting range
DB42
2CDC231026F0013
7
1SFC151402F0001
TF42 + DB42
KPR-101L
A
0.10 ... 0.13
0.13 ... 0.17
0.17 ... 0.23
0.23 ... 0.31
0.31 ... 0.41
0.41 ... 0.55
0.55 ... 0.74
0.74 ... 1.00
1.00 ... 1.30
1.30 ... 1.70
1.70 ... 2.30
2.30 ... 3.10
3.10 ... 4.20
4.20 ... 5.70
5.70 ... 7.60
7.60 ... 10.0
10.0 ... 13.0
13.0 ... 16.0
16.0 ... 20.0
20.0 ... 24.0
24.0 ... 29.0
29.0 ... 35.0
35.0 ... 38.0/40.0
Short-circuit
protective device
Trip class
Type
Order code
0.5 A, fuse type T
1.0 A, fuse type T
1.0 A, fuse type T
1.0 A, fuse type T
2.0 A, fuse type gG
2.0 A, fuse type gG
4.0 A, fuse type gG
6.0 A, fuse type gG
6.0 A, fuse type gG
10.0 A, fuse type gG
10.0 A, fuse type gG
10.0 A, fuse type gG
20.0 A, fuse type gG
20.0 A, fuse type gG
35.0 A, fuse type gG
35.0 A, fuse type gG
40.0 A, fuse type gG
40.0 A, fuse type gG
63.0 A, fuse type gG
63.0 A, fuse type gG
63.0 A, fuse type gG
80.0 A, fuse type gG
80.0 A, fuse type gG
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
1SAZ721201R1005
1SAZ721201R1008
1SAZ721201R1009
1SAZ721201R1013
1SAZ721201R1014
1SAZ721201R1017
1SAZ721201R1021
1SAZ721201R1023
1SAZ721201R1025
1SAZ721201R1028
1SAZ721201R1031
1SAZ721201R1033
1SAZ721201R1035
1SAZ721201R1038
1SAZ721201R1040
1SAZ721201R1043
1SAZ721201R1045
1SAZ721201R1047
1SAZ721201R1049
1SAZ721201R1051
1SAZ721201R1052
1SAZ721201R1053
1SAZ721201R1055
Weight
(1 pce)
kg
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.130
0.145
0.145
0.145
0.145
0.145
Ordering details accessories
Suitable for
Description
Type
Order code
TF42
TF42
Single mounting kit
Reset push button*
DB42
KPR-101L
1SAZ701902R0001
1SFA616162R1014
Weight
(1 pce)
kg
0.087
0.027
*Note: for more information see cataloge 1SFC151004C0201
Main dimensions
0.64"
2.3
0.09"
mm, inches
11.7 0.46"
50.25
2.7 0.11"
1.98"
TF42
7/8 | ABB
12.35 0.49"
14.4 0.57"
45
1.77"
52.6
2.07"
66.4
70.5
2.61"
2.78"
2CDC106046C0201
9.1 0.36"
8.1 0.32"
2CDC232005F0009
88.3
3.48"
16.2
TF42 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF42
IEC/EN 60947–4–1, IEC/EN 60947-5-1, IEC/EN 60947-1
690 V AC
50/60 Hz
10
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
6 kV
690 V AC
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF42
600 V
N.C., 95-96 6 A
N.O., 97-98 4 A
DC, 50/60 Hz
1 N.O. + 1 N.C.
3.00
0.75
3.00
0.75
0.75
0.75
N.C., 95-96 0.75
N.O., 97-98 0.75
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
A
A
A
A
A
A
A
A
7
1.25 A
1.25 A
0.55 A
0.55 A
0.27 A
0.27 A
17 V / 3 mA
N.C., 95-96 6 A, fuse type gG
N.O., 97-98 4 A, fuse type gG
6 kV
690 V
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Technical diagram – Intermittent periodic duty
(Op/h)
140
120
s
0.5
80
ta
20
ta =
=1
s
ta =
1
ta
40
.5
3s
s
5s
0
0
20
40
60
80
duty ratio
100 (%)
2CDC232004F0214
60
=
switching frequency
ta =
100
2CDC106046C0201
ta: Motor starting time
ABB | 7/9
TF42 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
TF42
UL 508, CSA 22.2 No. 14
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Conventional thermal current
TF42
B600, Q300
D300, Q300
5A
2.5 A
Full load amps and short-circuit protective device
Type
TF42-0.13
TF42-0.17
TF42-0.23
TF42-0.31
TF42-0.41
TF42-0.55
TF42-0.74
TF42-1.0
TF42-1.3
TF42-1.7
TF42-2.3
TF42-3.1
TF42-4.2
TF42-5.7
TF42-7.6
TF42-10
TF42-13
TF42-16
TF42-20
TF42-24
TF42-29
TF42-35
TF42-38
0.13
0.17
0.23
0.31
0.41
0.55
0.74
1.00
1.30
1.70
2.30
3.10
4.20
5.70
7.60
10.0
13.0
16.0
20.0
24.0
29.0
35.0
38.0
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Short-circuit protective device
480 / 600 V AC
Short circuit rating RMS
Fuse type
symmetrical
18 kA
1 A, K5
18 kA
1 A, K5
18 kA
1 A, K5
18 kA
3 A, K5
18 kA
3 A, K5
18 kA
3 A, K5
18 kA
3 A, K5
18 kA
6 A, K5
18 kA
6 A, K5
18 kA
6 A, K5
18 kA
10 A, K5
18 kA
10 A, K5
18 kA
15 A, K5
18 kA
20 A, K5
18 kA
25 A, K5
18 kA
35 A, K5
18 kA
40 A, K5
18 kA
60 A, K5
18 kA
80 A, K5
18 kA
80 A, K5
18 kA
100 A, K5
18 kA
150 A, K5
18 kA
150 A, K5
480 / 600 V AC
Short circuit rating RMS
symmetrical
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
Fuse type
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
30 A, Class J
45 A, Class J
45 A, Class J
45 A, Class J
60 A, Class J
60 A, Class J
100 A, Class J
175 A, Class J
175 A, Class J
2CDC106046C0201
7
Full load amps (FLA)
7/10 | ABB
TF42 thermal overload relays
Technical data
General technical data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
TF42
3
Yes
Open - compensated
Open
-25 ... +60 °C
-25 ... +60 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
3g / 3 ... 150 Hz
Position 1-5
Mount on the contactor and tighten the screws of the main circuit terminals or with single
mounting kit on DIN rail (35 mm)
IP20
IP10
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Housing
Main circuit terminals
Degree of protection
Electrical connection
Main circuit
Type
TF42
(TF42-0.13 … TF42-16)
TF42
(TF42-20 … TF42-38)
0.75 ... 4 mm²
0.75 ... 4 mm²
AWG 18-10
AWG 18-10
12 mm
1.5 - 2.5 Nm / 13 … 22 Ib.in
M4 (Pozidriv 2)
1.5 ... 2.5 mm² or 2.5 ... 10 mm²
2.5 ... 4 mm² or 4 ... 6 mm²
AWG 14-6
AWG 14-6
7
Connecting capacity
Rigid
Flexible with insulated ferrule
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
Stripping length
Tightening torque
Recommended screw driver
2.5 - 2.7 Nm / 22 Ib.in
Only connect two different "conductor/wire" cross-sections, if they are within the indicated ranges
Auxiliary circuit
Type
Connecting capacity
TF42
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 x or 2 x
1 x or 2 x
1x
2x
1 x or 2 x
1 x or 2 x
1 x or 2 x
0.75 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
0.75 ... 1 mm² or 1 ... 2.5 mm²
AWG 18-12
AWG 18-12
9 mm
1.1 ... 1.5 Nm / 9 … 13 Ib.in
M3 (Pozidriv 2)
2CDC106046C0201
1)
1)
ABB | 7/11
TF65 thermal overload relays
22.0 to 67.0 A
2CDC231004F0013
Description
TF65
The TF65 thermal overload relays are economic electromechanical protection devices for the main circuit.
They offer reliable protection for motors in the event of overload or phase failure. The devices have trip
class 10.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows
through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over
current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a
change of the contacts switching position (95-96 / 97-98).
– – Manual or automatic reset selectable
– – Phase loss sensitive acc. to IEC/EN 60947-4-1
– – TEST and STOP function – Trip indication on the front
– – Temperature compensation
– – Suitable for three- and single-phase applications
1SFC151402F0001
Ordering details
KPR-101L
7
Setting range
A
22.0 ... 28.0
25.0 ... 33.0
30.0 ... 40.0
36.0 ... 47.0
44.0 ... 53.0
50.0 ... 60.0
57.0 ... 67.0
Short-circuit
protective device
Trip class
Type
Order code
80 A, gG Type Fuses
80 A, gG Type Fuses
100 A, gG Type Fuses
125 A, gG Type Fuses
125 A, gG Type Fuses
125 A, gG Type Fuses
160 A, gG Type Fuses
10
10
10
10
10
10
10
TF65-28
TF65-33
TF65-40
TF65-47
TF65-53
TF65-60
TF65-67
1SAZ811201R1001
1SAZ811201R1002
1SAZ811201R1003
1SAZ811201R1004
1SAZ811201R1005
1SAZ811201R1006
1SAZ811201R1007
Weight
(1 pce)
kg
0.456
0.456
0.456
0.456
0.456
0.466
0.466
Ordering details accessories
Suitable for
Description
Type
Order code
TF65
Reset push button*
KPR-101L
1SFA616162R1014
Weight
(1 pce)
kg
0.027
*Note: for more information see cataloge 1SFC151004C0201
Main dimensions
mm, inches
34.8 1.37"
10.1 0.40"
55.7 2.19"
4 0.08"
10.4
37.4
54.9
TF65
7/12 | ABB
0.41"
1.47"
2.16"
6T3
83.5 3.29"
102.8
4.05"
106.1
4.18"
106.9
4.21"
2CDC106063C0201
4T2
2CDC232005F0009
2T1
18.9 0.74"
65 2.56"
16.6 0.65"
46 1.81"
67.8 2.67"
101.4
87.7 3.45"
3.45"
7 0.28"
TF65 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF65
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
690 V AC
50/60 Hz
10
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
690 V
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF65
600 V
N.C., 95-96 6 A
N.O., 97-98 4 A
DC, 50/60 Hz
1 N.O. + 1 N.C.
3.00
0.75
3.00
0.75
0.75
0.75
N.C., 95-96 0.75
N.O., 97-98 0.75
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
A
A
A
A
A
A
A
A
7
1.25 A
1.25 A
0.55 A
0.55 A
0.27 A
0.27 A
17 V / 3 mA
N.C., 95-96 6 A, gG Type Fuses
N.O., 97-98 4 A, gG Type Fuses
6 kV
690 V
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Technical diagram – Intermittent periodic duty
(Op/h)
140
120
s
0.5
80
ta
20
ta =
=1
s
ta =
1
ta
40
.5
3s
s
5s
0
0
20
40
60
80
duty ratio
100 (%)
2CDC232004F0214
60
=
switching frequency
ta =
100
2CDC106063C0201
ta: Motor starting time
ABB | 7/13
TF65 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
TF65
UL 60947-1, UL 60947-4-1
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Conventional thermal current
TF65
B600, Q600
D300, Q600
6A
4A
Full load amps and short-circuit protective device
Type
TF65-28
TF65-33
TF65-40
TF65-47
TF65-53
TF65-60
TF65-67
28
33
40
47
53
60
67
A
A
A
A
A
A
A
Short-circuit protective device
480 / 600 V AC
Short circuit rating RMS
Fuse type
symmetrical
5 kA
100 A, K5
5 kA
100 A, K5
5 kA
100 A, K5
5 kA
125 A, K5
10 kA
125 A, K5
10 kA
150 A, K5
10 kA
150 A, K5
/
/
/
/
/
/
/
RK5
RK5
RK5
RK5
RK5
RK5
RK5
480 / 600 V AC
Short circuit rating RMS
symmetrical
18 kA
18 kA
18 kA
18 kA
18 kA
18 kA
18 kA
Fuse type
110
110
110
125
125
150
150
A,
A,
A,
A,
A,
A,
A,
Class
Class
Class
Class
Class
Class
Class
J
J
J
J
J
J
J
2CDC106063C0201
7
Full load amps (FLA)
7/14 | ABB
TF65 thermal overload relays
Technical data
General technical data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
TF65
3
Yes
Open - compensated
Open
-25 ... +60 °C
-25 ... +60 °C
-50 ... +80 °C
Acc. to IEC/EN 60947-4-1
2000 m
25g / 11 ms
5g / 3 ... 150 Hz
Position 1
Mount on the contactor and tighten the screws of the main circuit terminals or with single
mounting kit on DIN rail (35 mm)
IP20
IP10
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Housing
Main circuit terminals
Degree of protection
Electrical connection
Main circuit
Type
Connecting capacity
TF65
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 x or 2 x
1x
1 x or 2 x
1x
1 x or 2 x
1x
1 x or 2 x
1x
1x
2x
1x
2x
Stripping length
Tightening torque
Recommended screw driver
Only connect two different "conductor/wire" cross-sections, if they are within the indicated ranges
Auxiliary circuit
Type
Connecting capacity
TF65
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 x or 2 x
1 x or 2 x
1x
2x
1 x or 2 x
1 x or 2 x
1 x or 2 x
0.75 ... 4 mm²
0.75 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
0.75 ... 1 mm² or 1 ... 2.5 mm²
AWG 18 ... 12
AWG 18 ... 12
9 mm
1.1 ... 1.5 Nm / 9 … 13 Ib.in
M3 (Pozidriv 2)
2CDC106063C0201
1)
7
2.5 ... 16 mm²
2.5 ... 35 mm²
2.5 ... 10 mm²
2.5 ... 35 mm²
2.5 ... 4 mm²
2.5 ... 35 mm²
2.5 ... 16 mm²
2.5 ... 35 mm²
AWG 12 ... 2
AWG 12 ... 6
AWG 12 ... 2
AWG 12 ... 6
17 mm
4.0 - 4.5 Nm / 35 ... 40 Ib.in
M6 (Pozidriv 2)
ABB | 7/15
TF96 thermal overload relays
40.0 to 96.0 A
2CDC231005F0013
Description
TF96
The TF96 thermal overload relays are economic electromechanical protection devices for the main circuit.
They offer reliable protection for motors in the event of overload or phase failure. The devices have trip
class 10.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows
through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over
current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a
change of the contacts switching position (95-96 / 97-98).
– – Manual or automatic reset selectable
– – Phase loss sensitive acc. to IEC/EN 60947-4-1
– – TEST and STOP function – Trip indication on the front
– – Temperature compensation
– – Suitable for three- and single-phase applications
1SFC151402F0001
Ordering details
KPR-101L
7
Setting range
A
40.0 ... 51.0
48.0 ... 60.0
57.0 ... 68.0
65.0 ... 78.0
75.0 ... 87.0
84.0 ... 96.0
Short-circuit
protective device
Trip class
Type
Order code
125 A, gG Type Fuses
160 A, gG Type Fuses
160 A, gG Type Fuses
200 A, gG Type Fuses
200 A, gG Type Fuses
250 A, gG Type Fuses
10
10
10
10
10
10
TF96-51
TF96-60
TF96-68
TF96-78
TF96-87
TF96-96
1SAZ911201R1001
1SAZ911201R1002
1SAZ911201R1003
1SAZ911201R1004
1SAZ911201R1005
1SAZ911201R1006
Weight
(1 pce)
kg
0.620
0.620
0.620
0.620
0.620
0.630
Ordering details accessories
Suitable for
Description
Type
Order code
TF96
Reset push button*
KPR-101L
1SFA616162R1014
Weight
(1 pce)
kg
0.027
*Note: for more information see cataloge 1SFC151004C0201
Main dimensions
12.1 0.47"
mm, inches
45.8 1.80"
58.5 2.30"
67.5 2.66"
54.9
44.9
1.77"
69.9
7/16 | ABB
2.16"
2.75"
83.5 3.29"
102.8
4.05"
106.1
4.18"
106.9
4.21"
2CDC106064C0201
17.9 0.70"
6T3
2CDC232005F0009
4T2
18.9 0.74"
2T1
TF96
2.5 0.10"
16.6 0.65"
46 1.81"
70.3 2.77"
106.3
60.6 3.57"
4.19"
10 0.39"
TF96 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF96
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
690 V AC
50/60 Hz
10
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
690 V
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF96
600 V
N.C., 95-96 6 A
N.O., 97-98 4 A
DC, 50/60 Hz
1 N.O. + 1 N.C.
3.00
0.75
3.00
0.75
0.75
0.75
N.C., 95-96 0.75
N.O., 97-98 0.75
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
A
A
A
A
A
A
A
A
7
1.25 A
1.25 A
0.55 A
0.55 A
0.27 A
0.27 A
17 V / 3 mA
N.C., 95-96 6 A, fuse type gG
N.O., 97-98 4 A, fuse type gG
6 kV
690 V
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Technical diagram – Intermittent periodic duty
(Op/h)
140
120
s
0.5
80
ta
20
ta =
=1
s
ta =
1
ta
40
.5
3s
s
5s
0
0
20
40
60
80
duty ratio
100 (%)
2CDC232004F0214
60
=
switching frequency
ta =
100
2CDC106064C0201
ta: Motor starting time
ABB | 7/17
TF96 thermal overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
TF96
UL 60947-1, UL 60947-4-1
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Conventional thermal current
TF96
B600, Q600
D300, Q600
6A
4A
Full load amps and short-circuit protective device
Type
51
60
68
78
87
96
A
A
A
A
A
A
Short-circuit protective device
480 / 600 V AC
Short circuit rating RMS
Fuse type
symmetrical
5 kA
150 A, K5
10 kA
150 A, K5
10 kA
150 A, K5
10 kA
175 A, K5
10 kA
200 A, K5
10 kA
250 A, K5
/
/
/
/
/
/
RK5
RK5
RK5
RK5
RK5
RK5
480 / 600 V AC
Short circuit rating RMS
symmetrical
18 kA
18 kA
18 kA
18 kA
18 kA
18 kA
Fuse type
125
150
150
175
200
200
A,
A,
A,
A,
A,
A,
Class
Class
Class
Class
Class
Class
J
J
J
J
J
J
2CDC106064C0201
7
TF96-51
TF96-60
TF96-68
TF96-78
TF96-87
TF96-96
Full load amps (FLA)
7/18 | ABB
TF96 thermal overload relays
Technical data
General technical data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
TF96
3
Yes
Open - compensated
Open
-25 ... +60 °C
-25 ... +60 °C
-50 ... +80 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
5g / 3 ... 150 Hz
Position 1
Mount on the contactor and tighten the screws of the main circuit terminals or with single
mounting kit on DIN rail (35 mm)
IP20
IP10
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Housing
Main circuit terminals
Degree of protection
Electrical connection
Main circuit
Type
Connecting capacity
TF96
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 x or 2 x
1x
1 x or 2 x
1x
1 x or 2 x
1x
1 x or 2 x
1x
1x
2x
1x
2x
Stripping length
Tightening torque
Recommended screw driver
7
Only connect two different "conductor/wire" cross-sections, if they are within the indicated ranges
Auxiliary circuit
Type
Connecting capacity
TF96
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 x or 2 x
1 x or 2 x
1x
2x
1 x or 2 x
1 x or 2 x
1 x or 2 x
0.75 ... 4 mm²
0.75 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
0.75 ... 1 mm² or 1 ... 2.5 mm²
AWG 18 ...12
AWG 18 ... 12
9 mm
1.1 ... 1.5 Nm / 9 … 13 Ib.in
M3 (Pozidriv 2)
2CDC106064C0201
1)
6 ... 35 mm²
6 ... 50 mm²
6 ... 35 mm²
6 ... 50 mm²
6 ... 16 mm²
6 ... 50 mm²
6 ... 35 mm²
6 ... 50 mm²
AWG 8 ... 1
AWG 8 ... 3
AWG 8 ... 1
AWG 8 ... 3
22 mm
6.5 - 9 Nm / 57 ... 80 Ib.in
M8 (Hexagon)
ABB | 7/19
TF140DU thermal overload relays
66 to 142 A
2CDC231012F0012
Description
1SFC151402F0001
TF140DU
KPR-101L
7
The TF140DU thermal overload relays are economic electromechanical protection devices for the main
circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have
trip class 10A.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows
through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over
current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a
change of the contacts switching position (95-96 / 97-98).
– – Manual or automatic reset selectable
– – Phase loss sensitive acc. to IEC/EN 60947-4-1
– – TEST and STOP function – Trip indication on the front
– – Temperature compensation
– – Suitable for three- and single-phase applications
Ordering details
Setting range
A
66 ... 90
80 ... 110
100 ... 135
110 ... 142
Short-circuit
protective device
Trip class
Type
Order code
200 A, fuse type gG
224 A, fuse type gG
224 A, fuse type gG
250 A, fuse type gG
10A
10A
10A
10A
TF140DU-90
TF140DU-110
TF140DU-135
TF140DU-142
1SAZ431201R1001
1SAZ431201R1002
1SAZ431201R1003
1SAZ431201R1004
Weight
(1 pce)
kg
0.820
0.820
0.820
0.820
Ordering details accessories
Suitable for
Description
Type
Order code
TF140DU
Reset push button*
KPR-101L
1SFA616162R1014
Weight
(1 pce)
kg
0.027
*Note: for more information see cataloge 1SFC151004C0201
Main dimensions
mm, inches
89 3.5"
29.75 1.17"
37
19.9 0.78"
29.75 1.17"
6.4 3.5"
1.46"
5.5 0.22"
51 2.01"
4 0.16"
96
67.3 2.65"
95
4/T2
25 0.98"
6/T3
25 0.98"
6 0.24"
8 0.31"
126
TF140DU
7/20 | ABB
5.3 0.21"
50 1.97"
58.8 2.31"
4.96"
68
2.68"
80
3.15"
84.2
3.31"
2CDC106054C0201
2/T1
2CDC232008F0012
97
73.8 2.91"
98
82.3 3.24"
140
5.51"
13.45 0.53"
TF140DU thermal overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Frequency range
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF140DU
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
690 V AC
DC, 50/60 Hz
0 ... 400 Hz
10A
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
690 V
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TF140DU
500 V AC, 440 V DC
N.C., 95-96 10 A
N.O., 97-98 6 A
DC, 50/60 Hz
1 N.O. + 1 N.C.
3.00
1.50
1.50
1.50
1.00
1.00
N.C., 95-96 1.00
N.O., 97-98 1.00
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
7
A
A
A
A
A
A
A
A
1.25 A
1.25 A
0.25 A
0.25 A
0.25 A
0.25 A
0.12 A
0.04 A
17 V / 3 mA
N.C., 95-96 10 A, fuse type gG
N.O., 97-98 6 A, fuse type gG
6 kV
690 V
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Technical diagram – Intermittent periodic duty
(Op/h)
140
120
0.5
80
s
ta
.5
3s
s
5s
0
0
20
40
60
80
duty ratio
100 (%)
2CDC106054C0201
20
ta =
=1
s
ta =
1
ta
40
2CDC232004F0214
60
=
switching frequency
ta =
100
ta: Motor starting time
ABB | 7/21
TF140DU thermal overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
TF140DU
UL 508, CSA 22.2 No. 14, UL
600 V AC
125 % of FLA
See table "Full load amps and
See table "Full load amps and
See table "Full load amps and
60947-4-1A
short-circuit protective device"
short-circuit protective device"
short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
Conventional thermal current
N.C., 95-96
N.O., 97-98
N.C./N.O.
TF140DU
B600
C300
10 A / 6 A
Full load amps and short-circuit protective device
Type
TF140DU-90
TF140DU-110
TF140DU-135
TF140DU-142
/
/
/
/
RK5
RK5
RK5
RK5
480 / 600 V AC
Short circuit rating
RMS symmetrical
100 kA
100 kA
100 kA
100 kA
Fuse type
250
250
250
250
A,
A,
A,
A,
Class
Class
Class
Class
J
J
J
J
480 / 600 V AC
Short circuit rating
RMS symmetrical
100 kA
100 kA
100 kA
100 kA
Listed circuit breaker
250
250
250
250
A
A
A
A
2CDC106054C0201
7
Full load amps (FLA) Short-circuit protective device
480 / 600 V AC
Short circuit rating
Fuse type
RMS symmetrical
90 A
10 kA
250 A, K5
110 A
10 kA
250 A, K5
135 A
10 kA
250 A, K5
142 A
10 kA
250 A, K5
7/22 | ABB
TF140DU thermal overload relays
Technical data
General technical data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
TF140DU
3
Yes
Open - compensated
Open
-25 ... +55 °C
-25 ... +55 °C
-40 ... +70 °C
Acc. to IEC/EN 60947-4-1
2000 m
12g / 11 ms
Position 1-5
Mount on the contactor and tighten the screws of the main circuit terminals
IP20
IP00
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Mounting position
Mounting
Degree of protection
Housing
Main circuit terminals
Electrical connection
Main circuit
Type
Connecting capacity
TF140DU
Rigid
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1x
2x
1x
2x
1 x or 2 x
1 x or 2 x
Stripping length
Tightening torque
Recommended screw driver
Auxiliary circuit
Type
Connecting capacity
16 ... 70 mm²
16 ... 70 mm²
AWG 6-2/0
AWG 6-2/0
25 mm
8 ... 10 Nm / 77 ... 88 Ib.in
M8 (Hexagon)
7
TF140DU
Stripping length
Tightening torque
Recommended screw driver
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
0.75 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 18-14
AWG 18-14
9 mm
0.8 ... 1.3 Nm / 12 Ib.in
M3.5 (Pozidriv 2)
2CDC106054C0201
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
ABB | 7/23
TA200DU thermal overload relays
66 to 200 A
2CDC231016F0013
Description
1SFC151402F0001
TA200DU
KPR-101L
7
The TA200DU thermal overload relays are economic electromechanical protection devices for the main
circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have
trip class 10A.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows
through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over
current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a
change of the contacts switching position (95-96 / 97-98).
– – Manual or automatic reset selectable
– – Phase loss sensitive acc. to IEC/EN 60947-4-1
– – TEST and STOP function – Trip indication on the front
– – Temperature compensation
– – Suitable for three- and single-phase applications
Ordering details
Setting range
A
66 ... 90
80 ... 110
100 ... 135
110 ... 150
130 ... 175
150 ... 200
Short-circuit
protective device
Trip class
Type
Order code
200 A, fuse type gG / 125 A aM
224 A, fuse type gG / 160 A aM
224 A, fuse type gG / 200 A aM
250 A, fuse type gG / 200 A aM
315 A, fuse type gG / 250 A aM
315 A, fuse type gG / 250 A aM
10A
10A
10A
10A
10A
10A
TA200DU-90
TA200DU-110
TA200DU-135
TA200DU-150
TA200DU-175
TA200DU-200
1SAZ421201R1001
1SAZ421201R1002
1SAZ421201R1003
1SAZ421201R1004
1SAZ421201R1005
1SAZ421201R1006
Weight
(1 pce)
kg
0.755
0.760
0.760
0.760
0.770
0.785
Ordering details accessories
Suitable for
Description
Type
Order code
TA200DU
TA200DU
TA200DU
Terminal shroud
Single mounting kit
Reset push button*
LT200/A
DB200
KPR-101L
1SAZ401901R1001
1SAZ401110R0001
1SFA616162R1014
Weight
(1 pce)
kg
0.090
0.225
0.027
*Note: for more information see cataloge 1SFC151004C0201
Main dimensions
mm, inches
35 1.38"
35 1.38"
37 1.46"
23 0.91"
26 1.02"
Ø8.5 Ø0.33"
3 0.12"
6 0.24"
42 1.65"
4.96"
2CDC106038C0201
4 0.16"
126
50 1.97"
42 1.65"
6 0.24"
61 2.4"
2CDC232021F0011
10 0.39"
8 0.31"
Ø 5.3 Ø 0.21"
Ø 11 Ø 0.43"
20 0.79"
TA200DU
4 0.16"
82.3 3.24"
49.9
22.1 0.87"
80 3.15"
7/24 | ABB
32 1.26"
11 0.43"
68 2.68"
151
5.94"
30.9 1.22"
2"
5.5 0.22"
TA200DU thermal overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Frequency range
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TA200DU
IEC/EN 60947-1, IEC/EN 60947-4-1
690 V AC
DC, 50/60 Hz
0 ... 400 Hz
10A
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
6 kV
690 V AC
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
TA200DU
500 V AC, 440 V DC
N.C., 95-96 10 A
N.O., 97-98 6 A
DC, 50/60 Hz
1 N.O. + 1 N.C.
3.00
1.50
3.00
1.50
1.00
1.00
N.C., 95-96 1.00
N.O., 97-98 1.00
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
7
A
A
A
A
A
A
A
A
1.25 A
1.25 A
0.25 A
0.25 A
0.25 A
0.25 A
0.12 A
0.04 A
17 V / 3 mA
N.C., 95-96 10 A, fuse type gG
N.O., 97-98 6 A, fuse type gG
6 kV
690 V
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
N.C., 95-96
N.O., 97-98
Technical diagram – Intermittent periodic duty
(Op/h)
140
120
0.5
80
s
ta
.5
3s
s
5s
0
0
20
40
60
80
duty ratio
100 (%)
2CDC106038C0201
20
ta =
=1
s
ta =
1
ta
40
2CDC232004F0214
60
=
switching frequency
ta =
100
ta: Motor starting time
ABB | 7/25
TA200DU thermal overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
TA200DU
UL 508, CSA 22.2 No. 14
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
Conventional thermal current
TA200DU
C600
B600
5A
Full load amps and short-circuit protective device
Type
TA200DU-90
TA200DU-110
TA200DU-135
TA200DU-150
TA200DU-175
TA200DU-200
90 A
110 A
135 A
150 A
175 A
200 A
Short-circuit protective device
480 / 600 V AC
Short circuit rating
RMS symmetrical
10 kA
10 kA
10 kA
10 kA
10 kA
10 kA
Fuse type
250
250
300
300
300
400
A,
A,
A,
A,
A,
A,
K5
K5
K5
K5
K5
K5
/
/
/
/
/
/
RK5
RK5
RK5
RK5
RK5
RK5
Listed circuit
breaker
225 A
225 A
225 A
225 A
225 A
400 A
Short circuit rating
RMS symmetrical
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
Fuse type
250
250
250
250
300
400
A,
A,
A,
A,
A,
A,
Class
Class
Class
Class
Class
Class
J
J
J
J
J
J
Short circuit rating
RMS symmetrical
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
Listed circuit
breaker
250 A
250 A
250 A
250 A
300 A
400 A
2CDC106038C0201
7
Full load amps
(FLA)
7/26 | ABB
TA200DU thermal overload relays
Technical data
General technical data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
TA200DU
3
Yes
Open - compensated
Open
-25 ... +55 °C
-25 ... +55 °C
-40 ... +70 °C
Acc. to IEC/EN60947-4-1
2000 m
12g / 15 ms
Position 1-6
Mount on the contactor and tighten the screws of the main circuit terminals or with single
mounting kit
IP20
IP00
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Mounting position
Mounting
Housing
Main circuit terminals
Degree of protection
Electrical connection
Main circuit
Type
Connecting capacity
TA200DU
Rigid
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Lugs
1x
1x
1x
1x
Tightening torque
Recommended screw driver
Auxiliary circuit
Type
Connecting capacity
25 ... 120 mm²
25 ... 120 mm²
AWG 4 ... 0000
AWG 4 ... 0000
L > 10 mm
25 Nm / 220 lb.in
Open bars
7
TA200DU
Stripping length
Tightening torque
Recommended screw driver
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
1 x or 2 x
0.75 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 18 ... 14
AWG 18 ... 14
9 mm
0.8 ... 1.3 Nm / 12 Ib.in
M3.5 (Pozidriv 2)
2CDC106038C0201
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
ABB | 7/27
E16DU, E45DU, E80DU, E140DU electronic overload relays
0.10 to 140 A
2CDC231001F0007
Description
The E16DU up to E140DU are self-supplied electronic overload relays, which means no extra external
supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to
use like a thermal overload relay and compatible with standard motor applications, the electronic overload
relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature
range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature
compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free
mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to
the contactors.
Ordering details
E16DU-1.0
Setting range
Short-circuit
protective device
Trip class
Type
Order code
Weight
(1 pce)
kg
E16DU electronic overload relays
0.10 … 0.32
1 A, fuse type gG
0.30 … 1.00
4 A, fuse type gG
0.80 … 2.70
10 A, fuse type gG
1.90 … 6.30
20 A, fuse type gG
5.70 … 18.9
50 A, fuse type gG
10E, 20E, 30E
10E, 20E, 30E
10E, 20E, 30E
10E, 20E, 30E
10E, 20E, 30E
E16DU-0.32
E16DU-1.0
E16DU-2.7
E16DU-6.3
E16DU-18.9
1SAX111001R1101
1SAX111001R1102
1SAX111001R1103
1SAX111001R1104
1SAX111001R1105
0.150
0.150
0.150
0.150
0.150
E45DU electronic overload relays
9.00 … 30.0
160 A, fuse type gG
15.0 … 45.0
160 A, fuse type gG
10E, 20E, 30E
10E, 20E, 30E
E45DU-30
E45DU-45
1SAX211001R1101
1SAX211001R1102
0.350
0.350
E80DU electronic overload relay
27.0 ... 80.0 A
250 A
10E, 20E, 30E
E80DU-80
1SAX311001R1101
0.770
E140DU electronic overload relay
50.0 ... 140.0 A
400 A
10E, 20E, 30E
E140DU-140
1SAX321001R1101
0.915
Weight
(1 pce)
kg
0.225
0.027
2CDC231002F0006
A
2CDC231003F0006
E80DU-80
Ordering details accessories
Suitable for
Description
Type
Order code
E16DU, E45DU, E80DU. E140DU
E16DU, E45DU, E80DU. E140DU
Single mounting kit
Reset push button*
DB200
KPR-101L
1SAZ401110R0001
1SFA616162R1014
*Note: for more information see cataloge 1SFC151004C0201
mm, inches
2CDC231004F0006
Main dimensions
43.7
1.72"
37
1.46"
66.4
3 0.12"
2.61"
2.4 0.37”
36.3 1.43”
8 0.32"
14 0.55"
0.71"
1.04"
18
0.37”
0.59"
9.3
0.37”
15
9.3
26.5
42
1.65"
8 0.32"
3 0.12"
1.2 0.5”
0.32”
14 0.55”
10.3 0.41”
37.5 1.48”
5.65 0.22”
44.4 1.75”
53
57
2.09”
2.24”
E16DU
3.71"
94.2
2.92"
74.2
16 0.63"
37
1.46"
58
2.28"
70
2.76"
5.5
3 0.12"
0.22"
74.5
2.93"
99
104.4
3.90"
4.11"
E80DU
KPR-101L
76 2.30“
E45DU
3.35"
18 0.71“
16 0.63“
3 1.46“
58 2.28“
70
2.76“
E140DU
5.5
0.22“
3 0.12“
74.5 2.93“
99
3.90“
104.4
4.11“
2CDC107030C0201
85.1
94.2 3.71“
38.4 1.51“
85.2 3.35“
79.7 3.14"
3 0.12“
8 0.12“
1.42"
57 2.24"
5 0.20“
0.21“
36
23.6 0.93"
38.4 1.51"
5.7 0.22"
2.66“
2CDC232008F0011
45 1.77"
5.5
2CDC232009F0011
14 0.55"
61 2.40"
29.2
10.3 0.41"
8.5 0.33"
53.5 2.11"
1.15"
9.6 0.38"
2.5 0.10"
14 0.55“
59.4 2.39"
27.3 1.07“
6.8 0.27"
2 0.08“
17 0.67"
4 0.16"
15 0.59“
0.08"
67.6
74.2 2.92“
2
49 1.93“
59.7 2.35“
37 1.46“
13 0.51“
7/28 | ABB
2CDC232010F0011
8.2
2CDC232007F0011
74.6 2.94”
85.2
3.35"
38.4
1.51"
E140DU-140
1SFC151402F0001
7
E45DU-30
E16DU, E45DU, E80DU, E140DU electronic overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
E16DU
E45DU
E80DU
E140DU
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
690 V AC
1000 V AC
50/60 Hz – not suitable for DC applications
10E, 20E, 30E, selectable
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
6 kV
690 V AC
1000 V AC
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
E16DU
600 V AC / DC
6A
DC, 50/60 Hz
1 N.C. + 1 N.O.
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3.00
3.00
1.10
0.72
E45DU
E80DU
E140DU
A
A
A
A
7
1.50 A
0.55 A
0.55 A
0.27 A
12 V / 3 mA
6 A, fuse type gG
6 kV
690 V
Technical diagram – Intermittent periodic duty
120
60
switching frequency
70
100
ta =
80
60
ta = 1
.5 s
40
ta = 3 s
ta = 5 s
20
0
1s
0
20
40
60
duty ratio
Trip class 10E
80
100 (%)
ta
=2
50
45
s
ta =
30
ta = 8
s
t a = 10
s
t a = 12
s
10
0
4s
ta = 6
20
0
20
=5
s
40
50
40
ta
s
40
60
duty ratio
Trip class 20E
80
100 (%)
35
30
25
ta =
20
15
ta = 1
5s
t a = 20
s
t a = 25 s
10
5
0
10 s
0
20
40
60
duty ratio
80
100 (%)
Trip class 30E
2CDC107030C0201
80
s
140
Trip class 30E
(Op/h)
2CDC232003F0214
.5
Trip class 20E
(Op/h)
2CDC232001F0214
switching frequency
=0
switching frequency
ta
160
2CDC232002F0214
Trip class 10E
(Op/h)
ABB | 7/29
E16DU, E45DU, E80DU, E140DU electronic overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
E16DU
E45DU
E80DU
UL 508, CSA 22.2, No. 14
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
E140DU
E16DU
B600,Q300
5A
E140DU
Auxiliary circuit according to UL/CSA
Type
Contact rating
Conventional thermal current
E45DU
E80DU
Short-circuit protective device
480 V AC
SCCR
Fuse type
50 kA
2 A, Class J
50 kA
2 A, K5 / RK5
50 kA
4 A, K5 / RK5
50 kA
15 A, K5 / RK5
50 kA
30 A, K5 / RK5
600 V AC
SCCR
5 kA
5 kA
5 kA
5 kA
5 kA
Fuse type
2 A, K5 / RK5
2 A, K5 / RK5
4 A, K5 / RK5
15 A, K5 / RK5
30 A, K5 / RK5
Short-circuit protective device
600 V AC
SCCR
Fuse type
18 kA
150 A, K5 / RK5
18 kA
200 A, K5 / RK5
SCCR
100 kA
100 kA
Fuse type
150 A, Class J
200 A, Class J
Full load amps and short-circuit protective device
Type
E16DU-0.32
E16DU-1.0
E16DU-2.7
E16DU-6.3
E16DU-18.9
0.32 A
1.00 A
2.70 A
6.30 A
18.90 A
Type
Full load amps (FLA)
E45DU-30
E45DU-45
30 A
45 A
Type
Full load amps (FLA)
E80DU-80
80 A
Type
Full load amps (FLA)
E140DU-140
140 A
SCCR
100 kA
100 kA
100 kA
100 kA
100 kA
Fuse type
2 A, Class J
2 A, Class J
4 A, Class J
15 A, Class J
30 A, Class J
Short-circuit protective device
600 V AC
SCCR
Fuse type
18 kA
300 A, K5 / RK5
Short-circuit protective device
600 V AC
SCCR
Fuse type
18 kA
400 A, K5 / RK5
2CDC107030C0201
7
Full load amps (FLA)
7/30 | ABB
E16DU, E45DU, E80DU, E140DU electronic overload relays
Technical data
General data
E16DU
3
Yes
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
Open - compensated
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
E80DU
E140DU
-25 ... +70 °C
-50 ... +85 °C
Acc. to IEC/EN60947-4-1
2000 m
15g / 11 ms
5g / 3 … 150 Hz
Position 1-6
Mount on the contactor and tighten the screws of the main circuit terminals or with single
mounting kit
IP20
IP20
Housing
Main circuit terminals
Degree of protection
E45DU
Electrical connection
Rigid
Flexible with insulated ferrule
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1x
2x
1x
2x
1x
2x
1x
2x
Stripping length
Tightening torque
Recommended screw driver
Auxiliary circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
E16DU
E45DU
E80DU
1 ... 4 mm²
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 16-10
AWG 16-10
AWG 16-10
AWG 16-10
9 mm
0.8 - 1.5 Nm / 7 Ib.in
M3.5 (Pozidriv 2)
2.5 ... 16 mm²
6 ... 95 mm²
2.5 ... 16 mm²
6 ... 35 mm²
2.5 ... 10 mm²
6 ... 70 mm²
2.5 ... 10 mm²
6 ... 35 mm²
AWG 14-6
AWG 10-0
AWG 14-6
AWG 14-6
AWG 10-0
AWG 14-6
13 mm
2.3 - 2.6 Nm / 22 Ib.in 6 - 6.5 Nm / 53 Ib.in
M5 (Pozidriv 2)
M8 (inbus 4)
E16DU
E45DU
E80DU
E140DU
6 ... 95 mm²
6 ... 35 mm²
6 ... 70 mm²
6 ... 35 mm²
AWG 8-0
AWG 8-0
6 - 6.5 Nm / 53 Ib.in
M8 (inbus 4)
7
E140DU
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 16-10
AWG 16-10
9 mm
0.8 ... 1.2 Nm / 7 Ib.in
M3.5 (Pozidriv 2)
2CDC107030C0201
Main circuit
Type
Connecting capacity
ABB | 7/31
E16DU, E45DU, E80DU, E140DU electronic overload relays
Accessories
Description
2CDC231003F0010
Single mounting kits are available as accessory for E16DU, E45DU, E80DU, and E140DU. The single
mounting kits offer the possibility to mount the overload relay separately from the contactor.
Ordering details
Description
Type
Order code
Weight
(1 pce)
kg
Single mounting kits
E16DU
E45DU
E80DU
E140DU
Single mounting kit
Single mounting kit
Single mounting kit
Single mounting kit
DB16E
DB45E
DB80E
DB140E
1SAX101110R0001
1SAX201110R1001
1SAX301110R1001
1SAX301110R1002
0.035
0.090
0.145
0.145
2CDC231004F0010
DB16E
Suitable for
DB45E
2CDC231005F0010
7
DB80E
mm, inches
98.5 3.88"
90.2 3.55"
35 1.38"
3 0.12"
2CDC231006F0010
Main dimensions
5.5 0.22"
4.5 0.18"
69.5 2.74"
65.2 2.57"
64.5 2.54"
DB16E
5.5 0.22"
35 1.38"
45 1.77"
10.5 0.41"
94.2 3.70"
95.6 3.76"
99 3.90"
81.5 3.21"
37 1.46"
5.5 0.22"
139.5 5.50"
DB140E
5.5 0.22"
4.3 0.17"
103 4.06"
104.4 4.11"
2CDC107030C0201
85.2 3.35"
62.5 2.46"
21.1 0.83"
37 1.46"
43.7 1.72"
70 2.76"
2CDC232029F0011
103 4.06"
104.4 4.11"
4.2 0.17"
94.2 3.71"
133.5 5.26"
85.2 3.35"
68.5 2.70"
4.3 0.17"
5 0.20"
5.5 0.22"
29.6 1.17"
2CDC232028F0011
5 0.20"
21.1 0.83"
62.5 2.46"
94.2 3.71"
4.2 0.17"
4.3 0.17"
68.5 2.70"
4.3 0.17"
29.6 1.17"
37 1.46"
43.7 1.72"
70 2.76"
33.7 1.33"
99 3.90"
33.7 1.33"
5.5 0.22"
7/32 | ABB
2CDC232027F0011
51 2.01"
57 2.44"
20.2 0.80"
3 0.12"
14 0.55" 14 0.55"
DB45E
37 1.46"
DB80E
61 2.40"
125.5 4.94"
4.2 0.17"
12.5 0.49"
68.5 2.70"
4.8 0.19"
5.5 0.22"
44.3 1.74"
29.6 1.17"
91 3.59"
50 1.97"
64.4 2.54"
14 0.55"
2CDC232030F0011
14 0.55"
41.7 1.64"
35.7 1.41"
4.2 0.17"
82.6 3.25"
113 4.45"
DB140E
102.5 4.04"
14.5 0.57"
EF19, EF45 electronic overload relays
0.10 to 45.0 A
1SBC101147F0010
Description
The EF19 and EF45 are self-supplied electronic overload relays, which means no extra external supply
is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use
like a thermal overload relay and compatible with standard motor applications, the electronic overload
relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature
range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature
compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free
mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to
the contactors.
Ordering details
EF19-18.9
Setting range
Short-circuit
protective device
Trip class
Type
Order code
Weight
(1 pce)
kg
EF19 electronic overload relays
0.10 … 0.32
1 A, fuse type gG
10E, 20E, 30E
EF19-0.32
1SAX121001R1101
0.158
0.30 … 1.00
4 A, fuse type gG
10E, 20E, 30E
EF19-1.0
1SAX121001R1102
0.158
0.80 … 2.70
10 A, fuse type gG
10E, 20E, 30E
EF19-2.7
1SAX121001R1103
0.158
1.90 … 6.30
20 A, fuse type gG
10E, 20E, 30E
EF19-6.3
1SAX121001R1104
0.158
5.70 … 18.9
50 A, fuse type gG
10E, 20E, 30E
EF19-18.9
1SAX121001R1105
0.158
EF45 electronic overload relays
9.00 … 30.0
160 A, fuse type gG
10E, 20E, 30E
EF45-30
1SAX221001R1101
0.362
15.0 … 45.0
10E, 20E, 30E
EF45-45
1SAX221001R1102
0.362
Weight
(1 pce)
kg
0.042
0.019
1SBC101148F0010
A
EF45-30
160 A, fuse type gG
7
2CDC231024V0013
Ordering details accessories
Suitable for
Description
Type
Order code
EF19
EF19, EF45
Single mounting kit
Reset push button*
DB19EF
KPR-101L
1SAX101910R1001
1SFA616162R1014
*Note: for more information see cataloge 1SFC151004C0201
1SFC151402F0001
DB19EF
KPR-101L
Main dimensions
mm, inches
14 0.55"
14 0.55"
2 0.08"
38.8
1.53"
59.5
3.4 0.13"
2.34"
2.3 0.09"
104.7 4.12"
11.78 0.46"
1.2 0.05"
0.62"
EF19
5.65 0.22"
37.5
1.48"
55.4 2.18"
29.3 2.33"
10.3 0.41"
8.5 0.33"
14 0.55"
45 1.77"
5.65 0.22"
56.5
2.22"
82.1
86
3.23"
3.39"
2CDC232008F0009
14 0.55"
44.4 1.75"
EF45
ABB | 7/33
2CDC107032C0201
10.3 0.41"
8.2 0.32"
2CDC232007F0009
85
3.35"
15.73
EF19, EF45 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
EF19
EF45
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
690 V AC
50/60 Hz – not suitable for DC applications
10E, 20E, 30E, selectable
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
6 kV
690 V AC
Auxiliary circuit according to IEC/EN
EF19
600 V AC / DC
6A
DC, 50/60 Hz
1 N.C. + 1 N.O.
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3.00
3.00
1.10
0.75
EF45
A
A
A
A
1.50 A
0.55 A
0.55 A
0.27 A
12 V / 3 mA
6 A, fuse type gG
6 kV
690 V
Technical diagram – Intermittent periodic duty
.5
80
s
70
120
60
switching frequency
140
100
ta =
80
60
ta = 3 s
ta = 5 s
0
20
40
60
duty ratio
100 (%)
ta
=2
50
s
ta =
30
0
4s
ta = 8
s
t a = 10
s
t a = 12
s
10
0
20
=5
s
40
ta = 6
20
ta
45
50
40
Trip class 30E
(Op/h)
s
40
60
duty ratio
Trip class 20E
80
100 (%)
35
30
25
ta =
20
15
ta = 1
5s
t a = 20
s
t a = 25 s
10
5
0
10 s
0
20
40
60
duty ratio
80
100 (%)
Trip class 30E
2CDC107032C0201
Trip class 10E
80
2CDC232001F0214
.5 s
20
0
1s
ta = 1
40
Trip class 20E
(Op/h)
2CDC232003F0214
=0
switching frequency
ta
160
2CDC232002F0214
Trip class 10E
(Op/h)
switching frequency
7
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
7/34 | ABB
EF19, EF45 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
EF19
EF45
UL 508, CSA 22.2 No. 14
600 V AC
125 % of FLA
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
See table "Full load amps and short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
Conventional thermal current
EF19
B600, Q600
B600, Q600
5A
EF45
Full load amps and short-circuit protective device
Full load amps (FLA)
EF19-0.32
EF19-1.0
EF19-2.7
EF19-6.3
EF19-18.9
0.32 A
1.00 A
2.70 A
6.30 A
18.90 A
Type
Full load amps (FLA)
EF45-30
EF45-45
30 kA
45 kA
Short-circuit protective device
480 V AC
SCCR
Fuse type
50 kA
2 A, Class J
50 kA
2 A, K5 / RK5
50 kA
4 A, K5 / RK5
50 kA
15 A, K5 / RK5
50 kA
30 A, K5 / RK5
600 V AC
SCCR
5 kA
5 kA
5 kA
5 kA
5 kA
Fuse type
2 A, K5 / RK5
2 A, K5 / RK5
4 A, K5 / RK5
15 A, K5 / RK5
30 A, K5 / RK5
SCCR
100 kA
100 kA
100 kA
100 kA
100 kA
Fuse type
2 A, Class J
2 A, Class J
4 A, Class J
15 A, Class J
30 A, Class J
Short-circuit protective device
480 V AC
SCCR
Fuse type
18 kA
150 A, K5 / RK5
18 kA
200 A, K5 / RK5
600 V AC
SCCR
18 kA
18 kA
Fuse type
150 A, K5 / RK5
200 A, K5 / RK5
SCCR
100 kA
100 kA
Fuse type
150 A, Class J
200 A, Class J
7
2CDC107032C0201
Type
ABB | 7/35
EF19, EF45 electronic overload relays
Technical data
General data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
Open - compensated
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Degree of protection
Housing
Main circuit terminals
EF19
3
Yes
EF45
-25 ... +70 °C
-50 ... +85 °C
Acc. to IEC/EN60947-4-1
2000 m
15g / 11 ms
1g / 3 … 150 Hz
Position 1-6
Mount on the contactor and tighten the screws of the main circuit terminals
IP20
IP20
Electrical connection
Main circuit
Type
Connecting capacity
Rigid
Flexible with insulated ferrule
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
7
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
Stripping length
Tightening torque
Recommended screw driver
Auxiliary circuit
Type
Connecting capacity
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
EF45
1 ... 4 mm²
0.75 ... 2.5 mm²
AWG 16-10
AWG 16-10
9 mm
0.8 ... 1.5 Nm / 7 … 13 Ib.in
M3.5 (Pozidriv 2)
2.5 ... 16 mm²
2.5 ... 10 mm²
AWG 14-6
AWG 14-6
13 mm
2.3 ... 2.6 Nm / 20 … 22 Ib.in
EF19
EF45
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 18-10
AWG 18-10
9 mm
0.8 ... 1.2 Nm / 7 ... 11 Ib.in
M3 (Pozidriv 2)
2CDC107032C0201
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
EF19
7/36 | ABB
EF65, EF96, EF146 electronic overload relays
20 to 150 A
2CDC231001F0012
Description
The EF65, EF96 and EF146 are self-supplied electronic overload relays, which means no extra external
supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to
use like a thermal overload relay and compatible with standard motor applications, the electronic overload
relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature
range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature
compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free
mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to
the contactors.
Ordering details
EF65-70
2CDC231002F0012
Setting range
EF96-100
Trip class
Type
Order code
A
20 ... 56
Short-circuit
protective device
160 A, fuse type gG
10E, 20E, 30E
EF65-56
1SAX331001R1102
Weight
(1 pce)
kg
0.821
25 ... 70
160 A, fuse type gG
10E, 20E, 30E
EF65-70
1SAX331001R1101
0.821
36 ... 100
200 A, fuse type gG
10E, 20E, 30E
EF96-100
1SAX341001R1101
0.802
54 ... 150
315 A, fuse type gG
10E, 20E, 30E
EF146-150
1SAX351001R1101
0.879
Weight
(1 pce)
kg
0.019
Ordering details accessories
Suitable for
Description
Type
Order code
EF65, EF96, EF146
Reset push button*
KPR-101L
1SFA616162R1014
7
2CDC231003F0012
*Note: for more information see cataloge 1SFC151004C0201
EF146-150
Main dimensions
mm, inches
55 2.17"
43.7 1.72"
34.65 1.36"
56.6 2.23"
8 0.31"
8 0.31"
53.3 2.1"
3 0.12"
3 0.12"
17.2 0.68"
25.4 1"
2.91"
101.4 3.99"
105.2 4.14"
EF65-56 / EF65-70
89.05
3.51"
60.1
2.37"
13
4.06"
38.4 1.51"
11 0.43"
103.2
74.2 2.92"
5.5 0.22"
3 0.12"
74 2.91"
101.4 3.99"
105.2 4.14"
0.5"
15.5 0.61"
10 0.39"
4 0.16"
5.5 0.22"
3 0.12"
74
2.91"
101.4 3.99"
105.2 4.14"
2CDC107038C0201
16 0.63"
37 1.46"
58 2.28"
70 2.76"
2CDC232003F0012
11 0.43"
103.7
4.08"
38.4 1.51"
88.9 3.5"
85.2 3.35"
74.2 2.92"
4.69"
5"
127
139.4 5.49"
70 2.76"
EF96-100
6.6 0.26"
119.25
16 0.63"
37 1.46"
58 2.28"
2CDC232002F0012
74
70 2.76"
105.2 4.14"
121.7 4.79"
3 0.12"
5.5 0.22"
2CDC232001F0012
11 0.43"
16 0.63"
37 1.46"
58 2.28"
85.2 3.35"
10 0.39"
25.4 1"
10 0.39"
103.2 4.06"
120.2 4.73"
38.4 1.51"
3.35"
105.2 4.14"
2.92"
74.2
85.2
KPR-101L
117.4 4.62"
1SFC151402F0001
17.2 0.68"
EF146-150
ABB | 7/37
EF65, EF96, EF146 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
EF65, EF96, EF146
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
1000 V AC
50/60 Hz – not suitable for DC applications
10E, 20E, 30E, selectable
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
1000 V
Auxiliary circuit according to IEC/EN
EF65, EF96, EF146
600 V AC / DC
6A
DC, 50/60 Hz
1 N.C. + 1 N.O.
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3.00
3.00
1.10
0.75
A
A
A
A
1.50 A
0.55 A
0.55 A
0.27 A
12 V / 3 mA
6 A, fuse type gG
6 kV
690 V
Technical diagram – Intermittent periodic duty
.5
80
s
70
120
60
switching frequency
140
100
ta =
80
60
ta = 3 s
ta = 5 s
0
20
40
60
duty ratio
100 (%)
ta
=2
50
s
ta =
30
0
4s
ta = 8
s
t a = 10
s
t a = 12
s
10
0
20
=5
s
40
ta = 6
20
ta
45
50
40
Trip class 30E
(Op/h)
s
40
60
duty ratio
Trip class 20E
80
100 (%)
35
30
25
ta =
20
15
ta = 1
5s
t a = 20
s
t a = 25 s
10
5
0
10 s
0
20
40
60
duty ratio
80
100 (%)
Trip class 30E
2CDC107038C0201
Trip class 10E
80
2CDC232001F0214
.5 s
20
0
1s
ta = 1
40
Trip class 20E
(Op/h)
2CDC232003F0214
=0
switching frequency
ta
160
2CDC232002F0214
Trip class 10E
(Op/h)
switching frequency
7
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
400 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
7/38 | ABB
EF65, EF96, EF146 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
EF65, EF96, EF146
UL 508, CSA 22.2 No. 14, UL
600 V AC
125 % of FLA
See table "Full load amps and
See table "Full load amps and
See table "Full load amps and
60947-4-1A
short-circuit protective device"
short-circuit protective device"
short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
Conventional thermal current
EF65, EF96, EF146
B600, Q600
B600, Q600
6A
Full load amps and short-circuit protective device
EF65-56
EF65-70
EF96-100
EF146-150
Full load amps (FLA)
56 A
70 A
100 A
150 A
Short-circuit protective device
480 V AC
SCCR
Fuse type
10 kA
150 A, R5/RK5
10 kA
150 A, R5/RK5
10 kA
200 A, R5/RK5
10 kA
250 A, R5/RK5
600 V AC
SCCR
10kA
10kA
10kA
10kA
Fuse type
150 A, R5/RK5
150 A, R5/RK5
200 A, R5/RK5
250 A, R5/RK5
SCCR
100 kA
100 kA
100 kA
100 kA
Fuse type
175 A, J
175 A, J
225 A, J
350 A, J
7
2CDC107038C0201
Type
ABB | 7/39
EF65, EF96, EF146 electronic overload relays
Technical data
General data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
Open - compensated
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Degree of protection
Housing
Main circuit terminals
EF65, EF96, EF146
3
Yes
-25 ... +70 °C
-50 ... +85 °C
Acc. to IEC/EN 60947-4-1
2000 m
15g / 11 ms
5g / 3 … 150 Hz
Position 1-6
Mount on the contactor and tighten the screws of the main circuit terminals
IP20
IP10
Electrical connection
Main circuit
Type
Connecting capacity
EF65
EF96
EF146
4 ... 35 mm²
4 ... 35 mm²
4 ... 35 mm²
4 ... 35 mm²
AWG 10-2
6 ... 70 mm²
6 ... 35 mm²
6 ... 50 mm²
6 ... 35 mm²
AWG 8-2
AWG 10-2
AWG 8-2
Stripping length
Tightening torque
Recommended screw driver
20 mm
4 Nm / 35 lb.in
M8 (Pozidriv 2)
20 mm
6 Nm / 55 lb.in
M8 (Hexagon 4)
10 ... 95 mm²
10 ... 35 mm²
10 ... 70 mm²
10 ... 35 mm²
AWG 6-00
AWG 6-2
AWG 6-00
AWG 6-2
20 mm
8 Nm / 70 lb.in
M8 (Hexagon 4)
Auxiliary circuit
Type
Connecting capacity
EF65, EF96, EF146
Rigid
7
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 18-10
AWG 18-10
9 mm
0.8 ... 1.2 Nm / 7 ... 11 Ib.in
M3.5 (Pozidriv 2)
2CDC107038C0201
Stripping length
Tightening torque
Recommended screw driver
1x
2x
1x
2x
1x
2x
1x
2x
7/40 | ABB
EF205, EF370 electronic overload relays
63 to 380 A
2CDC231004F0012
Description
The EF205 and EF370 are self-supplied electronic overload relays, which means no extra external supply
is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use
like a thermal overload relay and compatible with standard motor applications, the electronic overload
relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature
range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature
compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free
mechanism, STOP and TEST function and a trip indication. The overload relays are connected directly to
the contactors.
Ordering details
EF205-210
Setting range
Trip class
Type
Order code
A
63 ... 210
Short-circuit
protective device
1250 A, fuse type gG
10E, 20E, 30E
EF205-210
1SAX531001R1101
Weight
(1 pce)
kg
1.210
115 ... 380
1600 A, fuse type gG
10E, 20E, 30E
EF370-380
1SAX611001R1101
1.430
Weight
(1 pce)
kg
0.027
2CDC231005F0012
Ordering details accessories
Suitable for
Description
Type
Order code
EF205, EF370
Reset push button*
KPR-101L
1SFA616162R1014
7
*Note: for more information see cataloge 1SFC151004C0201
1SFC151402F0001
Main dimensions
mm, inches
122.8
105
4.13"
7.4 0.29"
17.9
116.5
10 0.39"
EF370-380
0.7"
30 1.18"
4.83"
4.59"
5 0.2"
151 5.9"
122 4.8"
5 0.2"
17.5 0.69"
Ø 0.33"
35 1.38"
35 1.38"
35 1.38"
2CDC232004F0012
Ø 8.5
10 0.39"
18.5 0.73"
11 0.43"
KPR-101L
5 0.2"
121.7
4.79"
EF205-210
122.8
10 0.39"
5 0.2"
43.8 1.72"
20
0.79"
43.8 1.72"
35 1.38"
5 0.2"
121.7
4.79"
2CDC107040C0201
Ø 0.43"
2CDC232005F0012
Ø 11
14 0.55"
22.8
0.9"
122
5 0.2"
30 1.18"
6.4"
0.7"
4.83"
4.59"
163.6
17.9
93.8 3.69"
0.29"
11 0.43"
7.4
116.5
4.13"
0.4'
105
EF370-380
ABB | 7/41
EF205, EF370 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
EF205, EF370
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
1000 V AC
50/60 Hz – not suitable for DC applications
10E, 20E, 30E, selectable
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
1000 V
Auxiliary circuit according to IEC/EN
EF205, EF370
600 V AC / DC
6A
DC, 50/60 Hz
1 N.C. + 1 N.O.
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3.00
3.00
1.10
0.75
A
A
A
A
1.50 A
0.55 A
0.55 A
0.27 A
12 V / 3 mA
6 A, fuse type gG
6 kV
690 V
Technical diagram – Intermittent periodic duty
.5
80
s
70
120
60
switching frequency
140
100
ta =
80
60
ta = 3 s
ta = 5 s
0
20
40
60
duty ratio
100 (%)
ta
=2
50
s
ta =
30
0
4s
ta = 8
s
t a = 10
s
t a = 12
s
10
0
20
=5
s
40
ta = 6
20
ta
45
50
40
Trip class 30E
(Op/h)
s
40
60
duty ratio
Trip class 20E
80
100 (%)
35
30
25
ta =
20
15
ta = 1
5s
t a = 20
s
t a = 25 s
10
5
0
10 s
0
20
40
60
duty ratio
80
100 (%)
Trip class 30E
2CDC107040C0201
Trip class 10E
80
2CDC232001F0214
.5 s
20
0
1s
ta = 1
40
Trip class 20E
(Op/h)
2CDC232003F0214
=0
switching frequency
ta
160
2CDC232002F0214
Trip class 10E
(Op/h)
switching frequency
7
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
400 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
7/42 | ABB
EF205, EF370 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
Full load amps (FLA)
Short-circuit rating RMS symmetrical
Short-circuit protective device
EF205, EF370
UL 508, CSA 22.2 No. 14, UL
600 V AC
125 % of FLA
See table "Full load amps and
See table "Full load amps and
See table "Full load amps and
60947-4-1A
short-circuit protective device"
short-circuit protective device"
short-circuit protective device"
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
Conventional thermal current
EF205, EF370
B600, Q600
B600, Q600
6A
Full load amps and short-circuit protective device
EF205-210
EF370-380
Full load amps (FLA)
210 A
380 A
Short-circuit protective device
480 V AC
SCCR
Fuse type
10 kA
400 A, R5/RK5
18 kA
800 A, L/T
600 V AC
SCCR
10kA
18kA
Fuse type
400 A, R5/RK5
800 A, L/T
SCCR
100 kA
-
Fuse type
400 A, J
-
7
2CDC107040C0201
Type
ABB | 7/43
EF205, EF370 electronic overload relays
Technical data
General data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
Open - compensated
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Mounting position
Mounting
Degree of protection
EF205
3
Yes
EF370
-25 ... +70 °C
-50 ... +85 °C
Acc. to IEC/EN 60947-4-1
2000 m
25g / 11 ms
5g / 3 … 150 Hz
Position 1-6
Mount on the contactor and tighten the screws
of the main circuit terminals
IP20
IP20
Housing
Main circuit terminals
Electrical connection
Main circuit
Type
Connecting capacity
Rigid
7
Flexible
Lugs
Bars
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1x
2x
1x
2x
L≤
Ø>
1x
2x
1x
2x
Stripping length
Tightening torque
Recommended screw driver
Auxiliary circuit
Type
Connecting capacity
EF370
16 ... 185 mm²
16 ... 120 mm²
16 ... 185 mm²
16 ... 120 mm²
24 mm
8 mm
AWG 6-0000
AWG 6-0000
AWG 6-0000
AWG 6-0000
18 Nm / 160 lb.in
M8
50 ... 240 mm²
50 ... 150 mm²
50 ... 240 mm²
50 ... 150 mm²
32 mm
10 mm
AWG 1-500 kcmil
AWG 1-500 kcmil
AWG 1-500 kcmil
AWG 1-500 kcmil
28 Nm / 247 lb.in
M10
EF205, EF370
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 18-10
AWG 18-10
9 mm
0.8 ... 1.2 Nm / 7 ... 11 Ib.in
M3.5 (Pozidriv 2)
2CDC107040C0201
Stripping length
Tightening torque
Recommended screw driver
EF205
7/44 | ABB
EF460, EF750 electronic overload relays
150 to 800 A
2CDC231013F0013
Description
The EF460 and EF750 are self-supplied electronic overload relays, which means no extra external supply
is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like
a thermal overload relay and compatible with standard motor applications, the electronic overload relay is
convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and
the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation,
trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP
and TEST function and a trip indication. Busbar kits are available as accessory for contactor mounting.
Ordering details
2CDC231014F0013
EF460-500
EF750-800
Setting
range
A
Short-circuit
protective device
Trip class
Type
Order code
Weight
(1 pce)
kg
EF460 electronic overload relay
150 ... 500 690 V: 630 A, Type gG
1000 V: 1600 A, Type gG
10E, 20E, 30E
EF460-500
1SAX721001R1101
1.170
EF750 electronic overload relay
250 ... 800 690 V: 800 A, Type gG
1000 V: 1600 A, Type gG
10E, 20E, 30E
EF750-800
1SAX821001R1101
3.905
Ordering details accessories
1SFC151402F0001
Suitable for
Description
EF460, EF750
Reset push button*
Type
Order code
KPR-101L
1SFA616162R1014
Weight
(1 pce)
kg
0.027
7
*Note: for more information see cataloge 1SFC151004C0201
KPR-101L
184.4 7.26"
187.9 7.4"
48.04 1.89"
103 4.06"
110.5 4.35"
186.8 7.35"
22 0.87"
149.9 5.9"
76 2.99"
74 2.91"
153.4 6.04"
38.8 1.53"
mm, inches
28.4 1.12"
152.3 6"
Main dimensions
41.5 1.63"
83 3.27"
21 0.83"
58 2.28"
32 1.26"
53.3 2.1"
40.5 1.59"
83 3.27"
82 3.23"
28 1.1"
2CDC232009F0013
19.5 0.77"
25.5 1"
2CDC232008F0013
247 9.72"
"
7 0.28"
13 0.51"
.2"
.28
Ø0
Ø0
EF460-500
.2
Ø7
192 7.56"
Ø5
EF750-800
ABB | 7/45
2CDC107045C0201
60 2.36"
80 3.15"
100 3.94"
76 2.99"
5.6 0.22"
55 2.17"
30.9 1.22"
58 2.28"
EF460, EF750 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
EF460
EF750
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
1000 V AC
50/60 Hz – not suitable for DC applications
10E, 20E, 30E, selectable
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
1000 V AC
Auxiliary circuit according to IEC/EN
EF460
600 V AC / DC
6A
DC, 50/60 Hz
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
400 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
1 N.C. + 1 N.O.
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3.00
3.00
1.10
0.75
EF750
A
A
A
A
1.50 A
0.55 A
0.55 A
0.27 A
12 V / 3 mA
6 A, fuse type gG
6 kV
690 V
Technical diagram – Intermittent periodic duty
.5
80
s
70
120
60
switching frequency
140
100
ta =
80
60
ta = 3 s
ta = 5 s
0
20
40
60
duty ratio
100 (%)
ta
=2
50
ta =
30
0
4s
ta = 8
s
t a = 10
s
t a = 12
s
10
0
20
=5
s
40
ta = 6
20
ta
45
s
50
40
Trip class 30E
(Op/h)
s
40
60
duty ratio
Trip class 20E
80
100 (%)
35
30
25
ta =
20
15
ta = 1
5s
t a = 20
s
t a = 25 s
10
5
0
10 s
0
20
40
60
duty ratio
80
100 (%)
Trip class 30E
2CDC107045C0201
Trip class 10E
80
2CDC232001F0214
.5 s
20
0
1s
ta = 1
40
Trip class 20E
(Op/h)
2CDC232003F0214
=0
switching frequency
ta
160
2CDC232002F0214
Trip class 10E
(Op/h)
switching frequency
7
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
7/46 | ABB
EF460, EF750 electronic overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
EF460
UL60947-1, UL60947-4-1
600 V AC
125 % of FLA
EF750
EF460
B600, Q300
B600, Q300
5A
EF750
EF460
3
Yes
EF750
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
Conventional thermal current
General data
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
Open - compensated
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Degree of protection
Housing
Main circuit terminals
-25 ... +70 °C
-25 ... +70 °C
Acc. to IEC/EN60947-4-1
2000 m
25g / 11 ms
3g / 3 … 150 Hz
IP20
IP00
7
Electrical connection
EF460
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
EF750
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 18-10
AWG 18-10
9 mm
0.8 ... 1.2 Nm / 7 ... 11 Ib.in
M3.5 (Pozidriv 2)
2CDC107045C0201
Auxiliary circuit
Type
Connecting capacity
ABB | 7/47
E1250DU electronic overload relays
375 to 1250 A
1SFC101025F0201
Description
The E1250DU are self-supplied electronic overload relays, which means no extra external supply is
needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to use like a
thermal overload relay and compatible with standard motor applications, the electronic overload relay is
convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and
the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation,
trip contact (N.C.), signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP
and TEST function and a trip indication. Busbar kits are available as accessory for contactor mounting.
Ordering details
Setting range
E1250DU-1250
A
Short-circuit
protective device
E1250DU electronic overload relay
375 ... 1250
-
Trip class
Type
Order code
Weight
(1 pce)
kg
10E, 20E, 30E
E1250DU-1250
1SFA739001R1000
12.181
2CDC107031C0201
7
7/48 | ABB
E1250DU electronic overload relays
Technical data
Main circuit – Utilization characteristics according to IEC/EN
Type
Standards
Rated operational voltage Ue
Rated frequency
Trip class
Number of poles
Duty time
Operating frequency without early tripping
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
E1250DU
IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
1000 V AC
50/60 Hz – not suitable for DC applications
10E, 20E, 30E, selectable
3
100 %
Up to 15 operations/h, see "Technical diagram – Intermittent periodic duty"
8 kV
1000 V AC
Auxiliary circuit according to IEC/EN
Type
Rated operational voltage Ue
Conventional free air thermal current Ith
Rated frequency
E1250DU
600 V AC / DC
6A
DC, 50/60 Hz
Number of poles
Ie / Rated operational current AC-15
acc. to IEC/EN 60947-5-1 for utilization category
110-120 V
220-230-240 V
440 V
480-500 V
Ie / Rated operational current DC-13
acc. to IEC/EN 60947-5-1 for utilization category
24 V
60 V
110-120-125 V
250 V
Minimum switching capacity
Short-circuit protective device
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
1 N.C. + 1 N.O.
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3.00
3.00
1.10
0.72
A
A
A
A
7
1.50 A
0.55 A
0.55 A
0.27 A
12 V / 3 mA
6 A, fuse type gG
8 kV
690 V
Technical diagram – Intermittent periodic duty
120
60
switching frequency
70
100
ta =
60
ta = 1
.5 s
40
ta = 3 s
ta = 5 s
20
0
1s
0
20
40
60
duty ratio
Trip class 10E
80
100 (%)
ta
=2
50
ta =
30
0
4s
ta = 8
s
t a = 10
s
t a = 12
s
10
0
20
=5
s
40
ta = 6
20
ta
45
s
50
40
Trip class 30E
(Op/h)
s
40
60
duty ratio
Trip class 20E
80
100 (%)
35
30
25
ta =
20
15
ta = 1
5s
t a = 20
s
t a = 25 s
10
5
0
10 s
0
20
40
60
duty ratio
80
100 (%)
Trip class 30E
2CDC107031C0201
80
s
140
80
Trip class 20E
(Op/h)
2CDC232003F0214
.5
2CDC232001F0214
switching frequency
=0
switching frequency
ta
160
2CDC232002F0214
Trip class 10E
(Op/h)
ABB | 7/49
E1250DU electronic overload relays
Technical data
Main circuit – Utilization characteristics according to UL/CSA
Type
Standards
Maximum operational voltage
Trip rating
E1250DU
UL 508, CSA 22.2 No. 14
600 V AC
125 % of FLA
Auxiliary circuit according to UL/CSA
Type
Contact rating
N.C., 95-96
N.O., 97-98
Conventional thermal current
E1250DU
B600, Q300
B600, Q300
5A
General data
E1250DU
3
Yes
-25 ... +70 °C
-50 ... +85 °C
Acc. to IEC/EN60947-4-1
2000 m
15g / 11 ms
5g / 3 … 150 Hz
IP20
IP20
Electrical connection
Auxiliary circuit
Type
Connecting capacity
E1250DU
Rigid
Flexible with ferrule
Flexible with insulated ferrule
Flexible
Stranded acc. to UL/CSA
Flexible acc. to UL/CSA
Stripping length
Tightening torque
Recommended screw driver
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 or 2 x
1 ... 4 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
AWG 16-10
AWG 16-10
9 mm
0.8 ... 1.2 Nm / 7 Ib.in
M3.5 (Pozidriv 2)
2CDC107031C0201
7
Type
Pollution degree
Phase loss sensitive
Ambient air temperature
Operation
Open - compensated
Storage
Ambient air temperature compensation
Maximum operating altitude permissible
Resistance to shock acc. to IEC 60068-2-27
Resistance to vibrations acc. to IEC 60068-2-6
Degree of protection
Housing
Main circuit terminals
7/50 | ABB
Thermal and electronic overload relays
General accessories
2CDC231028F0013
Description
WRB-400
The wire reset is a general accessory for thermal and electronic overloads relays. In installations which
are difficult to access, like a motor control centre or compact cubical, the accessory allows the user to
remotely reset the overload relays.
The wire reset consists of two parts, the bowden wire with actuator and the holder. The actuator should
be mounted into a door of a panel. The holder will be mounted on the overload relay. The actuator and
holder are connected via the bowden wire.
Ordering details
Length
Type
Order code
Weight
Pkg
(1 pce)
kg
WRH-F
1SAZ701903R1001
0.006
WRB-400
WRB-600
WRB-1000
1SAZ701903R1011
1SAZ701903R1012
1SAZ701903R1013
0.030
0.040
0.060
WRBG
1SAZ701903R1030
0.037
mm
Holder
TF42, TF65, TF96, Holder for tool less direct mounting
EF19, EF45, EF65,
EF96, EF146,
EF205, EF370,
EF460, EF750
Bowden wire with actuator
WRH-F
Bowden wire with actuator,
hole diameter: 7.3 mm,
maximum panel thickness: 12 mm
IP54 gasket
WRB-400
WRB-600
WRB-1000
IP54 Panel seal gasket
400
600
1000
7
Overload relays with accessory wire reset (WRH, WRB)
EF19 ... EF750
WRB-400/600/1000
TF42 ... TF96
WRH-F
2CDC131059C0201
WRH-F
Description
2CDC232015F0013
2CDC231027F0013
Suitable for
ABB | 7/51
Summary_8
8
8/0 | ABB
DRAS enclosed starter
DRAS enclosed starter
Ordering details
Control supply wiring versions
Wiring diagram
Main dimensions
8/2
8/3
8/3
8/3
Voltage code table
8/4
Summary_8
8
ABB | 8/1
DRAS09 … DRAS16 enclosed direct-on-line starters
4 to 7.5 kW, protected by thermal overload relays
AC or DC operated
Description
Enclosed direct-on-line (DOL) starters are used for controlling 3-phase asynchronous motors up to 690 V AC.
1SBC133003V0014
Each starter is delivered assembled and wired. It contains:
–– IP65 compact plastic enclosure with double insulation, equipped with:
-- 1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button
-- 2 quarter-turn, quick fastening screws and a base with 6 cable inlets and outlets via knockouts.
–– 1 AS or ASL 3-pole contactor with holding contact
–– 1 PE and 1 neutral terminal.
DRAS
+ T16 to be ordered separately
3 versions of control supply wiring are available: phase-to-phase, separate supply or phase-to-neutral.
T16 thermal overload relay has to be ordered separately and choses according to motor's nominal current
(see table below).
DRAS, DRASL enclosed DOL starters
IEC - AC-3
Rated operational
power
220 V
400 V 500 V
230 V
240 V
kW
kW
kW
Rated control circuit Control supply
voltage
wiring
Uc
DC operated with ASL 3-pole contactors
2.2
4
4
9
24
48
3
5.5
5.5
12
24
48
4
7.5
7.5
15.5
24
48
Pkg
(1 pce)
kg
Separate supply
Phase-to-neutral
Phase-to-neutral
Phase-to-phase
Phase-to-phase
Separate supply
Phase-to-neutral
Phase-to-neutral
Phase-to-phase
Phase-to-phase
Separate supply
Phase-to-neutral
Phase-to-neutral
Phase-to-phase
Phase-to-phase
DRAS09-20S
DRAS09-26N
DRAS09-27N
DRAS09-28P
DRAS09-29P
DRAS12-20S
DRAS12-26N
DRAS12-27N
DRAS12-28P
DRAS12-29P
DRAS16-20S
DRAS16-26N
DRAS16-27N
DRAS16-28P
DRAS16-29P
1SBK104235R2000
1SBK104135R2600
1SBK104135R2700
1SBK104035R2800
1SBK104035R2900
1SBK114235R2000
1SBK114135R2600
1SBK114135R2700
1SBK114035R2800
1SBK114035R2900
1SBK124235R2000
1SBK124135R2600
1SBK124135R2700
1SBK124035R2800
1SBK124035R2900
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
0.650
Separate supply
DRASL09-81S
DRASL09-83S
DRASL12-81S
DRASL12-83S
DRASL16-81S
DRASL16-83S
1SBK104335R8100
1SBK104335R8300
1SBK114335R8100
1SBK114335R8300
1SBK124335R8100
1SBK124335R8300
0.700
0.700
0.700
0.700
0.700
0.700
Weight
(1 pce)
kg
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.100
0.104
0.104
0.104
Separate supply
Separate supply
Setting range
1SBC133001V0014
A
0.10…0.13
0.13…0.17
0.17…0.23
0.23…0.31
0.31…0.41
0.41…0.55
0.55…0.74
0.74…1.00
1.00…1.30
1.30…1.70
1.70…2.30
2.30…3.10
3.10…4.20
4.20…5.70
5.70…7.60
7.60…10.0
10.0…13.0
13.0…16.0
Short-circuit
protective device
Trip class
Type
Order code
0.5 A, Fuse type T
1.0 A, Fuse type T
10
T16-0.13
T16-0.17
T16-0.23
T16-0.31
T16-0.41
T16-0.55
T16-0.74
T16-1.0
T16-1.3
T16-1.7
T16-2.3
T16-3.1
T16-4.2
T16-5.7
T16-7.6
T16-10
T16-13
T16-16
1SAZ711201R1005
1SAZ711201R1008
1SAZ711201R1009
1SAZ711201R1013
1SAZ711201R1014
1SAZ711201R1017
1SAZ711201R1021
1SAZ711201R1023
1SAZ711201R1025
1SAZ711201R1028
1SAZ711201R1031
1SAZ711201R1033
1SAZ711201R1035
1SAZ711201R1038
1SAZ711201R1040
1SAZ711201R1043
1SAZ711201R1045
1SAZ711201R1047
-
FR16AS-12VARS 1SBN101035R1000
2.0 A, Fuse type gG
4.0 A, Fuse type gG
6.0 A, Fuse type gG
10.0 A, Fuse type gG
20.0 A, Fuse type gG
35.0 A, Fuse type gG
40.0 A, Fuse type gG
Empty enclosure with push-button
-
-
To be completed with AS or ASL contactor, T16 thermal overload relay and MCB-10B (1SFA611610R2001) contact block.
0.394
1SBC133001S0201
2CDC231009V0013
8/2 | ABB
Weight
T16 thermal overload relays to be ordered separately
T16
Empty enclosure
with push-button
Order code
max.
Other control
current
voltages see
θ ≤ 40 °C voltage code table
Ue=400 V
A
V 50/60 Hz V DC
AC operated with AS 3-pole contactors
2.2
4
4
9
24
230
240
400
415
3
5.5
5.5
12
24
230
240
400
415
4
7.5
7.5
15.5
24
230
240
400
415
-
8
Type
DRAS09 … DRAS16 and
DRASL09 … DRASL16 enclosed direct-on-line starters
L1 L2 L3
N
V
Control supply wiring versions
L1 L2 L3
N
V
1 3 5
L1 L2 L3
Uc =
N
U
DRAS..S, DRASL..S
V
Uc
I Separate supply
A1
1 3 5 U
L1 L2 L3
DRAS
Uc =
O
1 3 5
L1 L2 L3
Uc
I
O
I
DRAS..P
Phase-to-neutral
Phase-to-phase
Us
A1
A1
Uc = Us
2 4 6
T1 T2 T3
A1
Uc = V
Uc =
A2
U
A2
A1
Uc = V
2 4 6
T1 T2 T3
R
Us
A2
DRAS..N
A2
A2
DRAS
R
O
R
DRAS
Uc
A1
DA.Cod1
L1 L2 L3
U
A1
A2
Uc = V
2 4 6
T1 T2 T3
A2
+
KM1: 5/L3
8
Us
M
96
A1+
-4
A1
1-phase
KM1
A2-
KM1: 3/L2
A2
DRAS..P
-
AC local control
DRAS09 ... DRAS16 + T16
DC local control
DRASL09 ... DRASL16..S + T16
mm, inches
131.5 5.18"
92 3.62"
126.5 4.98"
7.5 0.30"
Main dimensions
KM1
I
14
96
Power circuit
Us
N
13
-3
KM1
DRAS..S
DRAS..N
FR1
STOP
14
-4
6/T3
2/T1
4/T2
FR1
6/T3
4/T2
2/T1
98
TEST
STOP
96
FR1
FR1
KM1
I
97
95
A
M
M
13
6/T3
4/T2
2/T1
6/T3
4/T2
2/T1
STOP
-3
RESET
RESET
14
14
A2
RESET
A
95
13
KM1
A
95
5/L3
DRAS..P
DRAS..N
DRAS..S
13
3/L2
1/L1
5/L3
3/L2
A1
1/L1
Wiring diagram
5.5 0.22"
M5
1SBC133002S0201
ø 20.5mm - ø 0.81" for ISO M20
ø 25.5mm - ø 1.00" for ISO M25
7.5 0.30"
M5
5.5 0.22"
DRAS09, DRAS12, DRAS16
DRASL09, DRASL12, DRASL16
160 6.30"
171.5 6.75"
Cable inlets
Cable outlet
Enclosure top
Enclosure back Enclosure bottom
2 x ø 20.5/25.5 mm 2 x ø 20.5 mm 2 x ø 20.5/25.5 mm
2 x ø 0.81/1.00"
2 x ø 0.81"
2 x ø 0.81/1.00"
ABB | 8/3
Voltage code table
DRAS09 ... DRAS16 and
DRASL09 ... DRASL16 enclosed DOL starters
Type
DR AS16 - 26N
AS
ASL
Contactor type
AC operated
DC operated
AS contactors
AC coil code
50 Hz
60 Hz
20 S
21 S
22 S
24 V
42 V
48 V
24 V
42 V
48 V
16
23
24
25
26
27
N
N
N
N
N
N
110 V
115 V
220 V
230 V
240 V
13
17
28
29
P
P
P
P
380 V
400 V
415 V
ASL contactors
DC coil code
81 S
83 S
24 V
48 V
Control supply wiring
S
Separate supply
120 V
110 V
115 V
220 V
230 V
240 V
N
Phase-to-neutral
380 V
277 V
400 V
415 V
P
Phase-to-phase
1SBC133003S0201
8
8/4 | ABB
Notes
N18
8
ABB | 8/5
Summary_9
9
9/0 | ABB
R contactors
Presentation 9/2
Overview
R contactors for the AC circuits switching
9/4
R contactors for the DC circuits switching
9/6
Questionnaire 9/8
Summary_9
9
ABB | 9/1
R contactors
85 to 5000 A
R contactors with variable number of poles and their
variants (contactors with N.C. + N.O. poles, couplers...)
are used for controlling power circuits up to 1000 V AC
or 1500 V DC. They are designed with common standard
components. With the combination of these elements
and the adaptation possibilities, special versions can
be provided. Designed for long-lasting operation and
demanding applications, the ABB R contactors are used
for many applications all over the world.
Flexibility of design
–– Variable number of poles
–– Adjustable number of auxiliary contacts
–– Optional combination of N.O. and N.C. poles
–– Mechanical or magnetic latching available.
Easy maintenance
–– Direct access to all the components of the contactor
–– Complete and didactic instruction manual
–– Spare parts available
–– Dedicated service for bar contactors.
Exceptional durability
– – Mechanical durability up to 10 millions operating cycles
– – Mechanical switching frequency up to 1200 cycles per hour
– – Electrical durability up to 350 000 operating cycles.
Ideal for heavy duty applications
– – High making and breaking capacity
–– Fully compatible with the requirements of utilization
categories AC-3, DC-3 and DC-5 (control of AC / DC
motors for mining, iron and steel industries...).
Custom-made solutions
– – More than 60 years' experience in dealing with customers
projects
– – Development of solutions from specifications
– – Pre-sales support to identify and define customer
requirements
– – Specialists available to help you, select your product or
optimize your configuration.
1SBC104003S0201
9
9/2 | ABB
R contactors
For heavy duty applications
R contactors meet the particular requirements of each
AC / DC control application up to 5000 A, where the
demands are increasing:
–– Power distribution
–– Photovoltaic, hydroelectric power stations
–– Batteries
–– Mining
–– Railway networks and rolling stock
–– Induction furnaces
–– Pump stations
–– Travelling cranes.
Control your AC applications up to 5000 A
AC-1 Rated operational current up to 5000 A
AC-3 Rated power up to 1500 kW (1520 A - 440 V)
Control your DC applications up to 5000 A
DC-1 Rated operational current up to 5000 A
DC-3 / DC-5 Rated operational current up to 2000 A
1500 V with poles in series
9
1SBC104003S0201
Special applications
AC / DC coupling: LOR.. contactors
Slip ring motor control: FOR.. contactors
AC / DC switching (N.C. / N.O. main poles): NOR & JOR..
contactors
Latching contactors for energy saving and safety requirements: AMA or AME contactors
Field discharge: AM(F)-CC-JORE.. contactors
ABB | 9/3
R contactors for the AC circuits switching
1000 V AC
Current Ie up to 4500 A
Voltage Ue up to
Contactor
type
AC control circuit
IORR63..-MT
IORR125..-MT
IORR200..-MT
IORR400..-MT
IORR500..-MT
IORR800..-MT
DC control circuit
IORE63..-MT
IORE125..-MT
IORE200..-MT
IORE400..-MT
IORE500..-MT
IORE800..-MT
170 A
260 A
400 A
550 A
800 A
Categories
AC-1
Ue
at 40 °C
AC-3
Ie 85 A
690 V AC
Ie 85 A
160 A
260 A
400 A
550 A
800 A
1000 V AC max.
Ie 56 A
105 A
180 A
280 A
380 A
580 A
150 kW
240 kW
400 kW
540 kW
780 kW
690 V AC
AC-3
Power 80 kW
9
500 V AC
Current Ie up to 5000 A
Voltage Ue up to
AC control circuit
–
IORR800
DC control circuit
–
IORE800
Categories
AC-1
Ue
at 40 °C
AC-3
380-415-440 V AC
500 V AC max.
AC-3
400 V AC
Ie
From 85 A to 550 A, select above IOR..-MT
900 A
Ie
–
800 A
Ie
–
800 A
Power
–
450 kW
Recap:
All contactors fulfill the IEC 60947-4-1 / EN 60947-4-1 standards.
Utilization category AC-1:
max. breaking current = 1.5 x Ie,
max. making current = 1.5 x Ie.
Utilization category AC-3:
max. breaking current = 8 x Ie,
max. making current = 10 x Ie.
9/4 | ABB
Contactors with NC poles, magnetic or mechanical latching devices
on request.
1SBC104002S0201
Contactor
type
IORR1400..-MT
IORR1700..-MT
IORR2100..-MT
IORR2500..-MT
IORR3200..-MT
IORR3800..-MT
IORR4500..-MT
IORR5100..-MT
IORE1400..-MT
IORE1700..-MT
IORE2100..-MT
IORE2500..-MT
IORE3200..-MT
IORE3800..-MT
IORE4500..-MT
IORE5100..-MT
1250 A
1650 A
1850 A
2200 A
3000 A
3500 A
4000 A
4500 A
970 A
1170 A
1270 A
–
–
–
–
–
610 A
680 A
810 A
–
–
–
–
–
1000 kW
1200 kW
1300 kW
–
–
–
–
–
9
IORR1400
IORR1700
IORR2100
IORR2500
IORR3200
IORR3800
IORR4500
IORR5100
IORE1000
IORE1400
IORE1700
IORE2100
IORE2500
IORE3200
IORE3800
IORE4500
IORE5100
1000 A
1350 A
1650 A
2000 A
2400 A
3200 A
3800 A
4500 A
5000 A
800 A
1060 A
1260 A
1520 A
–
–
–
–
–
800 A
1080 A
1220 A
1340 A
–
–
–
–
–
450 kW
630 kW
750 kW
900 kW
–
–
–
–
–
1SBC104002S0201
IORR1000
ABB | 9/5
R contactors for the DC circuits switching
1500 V DC
Current Ie up to 5000 A
Voltage Ue up to
Contactor
type
AC control circuit
IORR63 ..-CC
IORR125 ..-CC
IORR200 ..-CC
IORR400 ..-CC
IORR500 ..-CC
DC control circuit
IORE63 ..-CC
IORE125 ..-CC
IORE200 ..-CC
IORE400 ..-CC
IORE500 ..-CC
Number of poles Categories
in series*
1 pole
2 poles
3 poles
Ue max.
DC-1
500 V DC
Ie 85 A
170 A
275 A
400 A
550 A
DC-3 / DC-5
500 V DC
Ie 68 A
140 A
205 A
350 A
500 A
DC-1
1000 V DC
Ie 85 A
170 A
275 A
400 A
550 A
DC-3 / DC-5
1000 V DC
Ie 68 A
140 A
205 A
350 A
500 A
DC-1
1500 V DC
Ie 85 A**
170 A**
275 A**
400 A**
550 A**
DC-3 / DC-5
1500 V DC
Ie 68 A**
140 A**
205 A**
350 A**
500 A**
*Number of poles to be fitted in series according to the operational voltage and the utilization categories.
**Version with increased insulation for 1000 V DC < Ue ≤ 1500 V DC, please consult us.
9
Contactors
UL / CSA approved
Voltage Ue up to
Current Ie up to
Contactor
type
600 V DC
2000 A
AC control circuit
IORR800-10-CC
IORR1000-10-CC
IORR1400-10-CC
IORR1700-10-CC
IORR2100-10-CC
DC control circuit
IORE800-10-CC
IORE1000-10-CC
IORE1400-10-CC
IORE1700-10-CC
IORE2100-10-CC
1000 A
1300 A
1700 A
2000 A
1 pole
General use
600 V DC
Ie 800 A
Recap:
All contactors fulfill the IEC 60947-4-1 / EN 60947-4-1 standards.
Utilization category DC-1:
max. breaking current = 1.5 x Ie,
max. making current = 1.5 x Ie.
Utilization categories DC-3 / DC-5:
max. breaking current = 4 x Ie,
max. making current = 4 x Ie.
9/6 | ABB
Contactors with NC poles, magnetic or mechanical latching devices
on request.
1SBC104001S0201
U max.
IORR800..-CC IORR1000..-CC IORR1400..-CC IORR1700..-CC IORR2100..-CC IORR2500..-CC IORR3200..-CC IORR3800..-CC IORR4500..-CC IORR5100..-CC
IORE800..-CC IORE1000..-CC IORE1400..-CC IORE1700..-CC IORE2100..-CC IORE2500..-CC IORE3200..-CC IORE3800..-CC IORE4500..-CC IORE5100..-CC
Ue max.
750 V DC
800 A
1000 A
1250 A
1600 A
2000 A
2300 A
3200 A
3800 A
4500 A
5000 A
600 V DC
720 A
1000 A
1250 A
1600 A
2000 A
On request
On request
On request
On request
On request
1500 V DC 800 A
1000 A
1250 A
1600 A
2000 A
2300 A
3200 A
3800 A
4500 A
5000 A
1000 V DC 720 A
1000 A
1250 A
1600 A
2000 A
On request
On request
On request
On request
On request
1500 V DC 800 A
1000 A
1250 A
1600 A
2000 A
2300 A
3200 A
3800 A
4500 A
5000 A
1500 V DC 720 A
1000 A
1250 A
1600 A
2000 A
On request
On request
On request
On request
On request
9
Product overview
CA15.. auxiliary contacts
1 N.O. + 1 N.C. fitted as
standard (extra auxiliary
contacts on request)
2 N.O. main poles with arc chutes
Auxiliary frame
for auxiliary contacts
Main frame
for contactor fixing
Connecting terminals
for coil supply
Lower terminal plate
for power circuit (utilization)
Electro-magnet (RR type),
laminated magnetic circuit,
AC coil, direct supply
1SBC104001S0201
Upper terminal plate
for power circuit (network)
ABB | 9/7
Questionnaire
Specification for R contactors
Customer ..................................................................................................................
Contact person ....................................................... Date ...............................
Tel. ........................................................... e-mail ...................................................
ABB ..............................................................................................................................
Contact person .....................................................................................................
Tel. ................................................................................................................................
Quantity .................... Requested delivery date ......................................
Project / Application ............................................................................................................................................................................................................................................
Power circuit
Auxiliary contacts
AC switching
Application type
AC-1 (resistive load)
AC-3 (direct starting, switching off running motors)
No load breaking
Other...............................................................................................
Number of poles: N.O. ...................... N.C. .....................
Rated operational current Ie ................... A
Max. making current ............................. A
Max. breaking current .......................... A
Rated operational voltage Ue ................ V ................ Hz
Number of N.O. auxiliary contacts .............
Number of N.C. auxiliary contacts ..............
or
Operating conditions
Switching frequency .............................................. cycles/h
Mech. durability required (millions of operating cycles) ...............
Remarks ...........................................................................................
Control circuit (coil)
AC Voltage
.. .................... V ................ Hz
.. .................... V DC
DC Voltage
Options
Magnetical latching
Mechanical latching
Accessories ..............................................................................................................................................................................................................................................
Please add any other useful documents for further information e.g. technical specification, drawing, wiring diagram, etc.
Replacement of an existing contactor
F
D
W
Please photocopy and forward. Questionnaire also available on the ABB Website:
www.abb.com/lowvoltage Section: Our offering Select: Control Products > Contactors > Bar mounted contactors
9/8 | ABB
1SBC104004S0201
Brand . . ...............................................................
Type ...................................................................
Fixing dimension
F = . ............... mm
Overall dimensions W = . ............... mm
H = . ............... mm
D = . ............... mm
H
9
DC switching
Application type
DC-1 (resistive load)
DC-3 (shunt motors)
DC-5 (series motors)
No load breaking
Other ........................................ L/R
............... ms
Number of poles: N.O. ...................... N.C. .....................
Rated operational current Ie ................... A
Making current ......................................... A
........... A
Breaking current min. ........... A max.
Rated operational voltage Ue ................ V DC
Questionnaire
Specification for R contactors
Other information / Application type
9
Please photocopy and forward. Questionnaire also available on the ABB Website:
www.abb.com/lowvoltage Section: Our offering Select: Control Products > Contactors > Bar mounted contactors
ABB | 9/9
1SBC104004S0201
This document is used to define the contactor specification according to the complete information on the application
2CDC135025C0201
10
10/0 | ABB
Motor control and protection
Motor control and protection
Benefits and advantages
10/2
Technical data
10/3
2CDC135025C0201
10
ABB | 10/1
Motor control and protection
Benefits and advantages
UMC100-FBP is a flexible, modular and expandable motor management system for constant-speed low-voltage range motors.
It's most important tasks include motor protection, prevention of plant standstills and the reduction of down time. This is made possible by
early information relating to possible motor problems which avoids unplanned plant standstills. Even if a motor trips, quick diagnosis of the cause of
the fault serves to reduce downtime.
UMC100-FBP combines in a very compact unit:
Motor protection
Overload, underload
Overvoltage, undervoltage
Blocked rotor, low / high current
Phase failure, imbalance, phase sequence
Earth leakage
Thermistor protection
Limitation of starts per time
One single version with integrated measuring system covers the rated
motor current from 0,24 to 63 A
Motor control
Integrated and easy to parametrize motor starter functions like direct,
reverse, star-delta,...
Additionally free programmable logic for application specific control
functions
Expansion modules DX111, DX122 for more I/Os
Expansion modules VI150, VI155 for 3-phase voltage measuring
Typical application segments
Oil & gas
Cement
Paper
Mining
Steel
Chemical industry
Motor diagnostics
Quick and comprehensive access to all relevant data
via fieldbus and/or operator panel
Current, thermal load
Phase voltages
Power factor
Energy
Further information
UMC & FBP Catalogue
UMC & FBP Brochure
2CDC 190 022 D0204
2CDC 135 011 B0202
2CDC135025C0201
10
Communication
Communication-independent basic device
Freely selectable fieldbus protocol with FieldBusPlug
Profibus DP
DeviceNet
Modbus
CANopen
Ethernet Modbus TCP
10/2 | ABB
Motor control and protection
Technical data
Basic device UMC100-FBP
UMC100-FBP allows the connection of one I/O-expansion module DX111 or DX122, and one voltage module VI150 or
VI155. Expansion modules are connected via 2-wire bus, the max. distance to UMC100-FBP is 3 m.
Main power
Voltage
Frequency
Rated motor current
max 1000 V AC
45 to 65 Hz
0.24 to 63 A, without accessories
Greater currents with transformer
11 mm (max 25 mm²)
5, 10, 20, 30, 40 in accordance with EN/IEC 60947-4-1
Separate fuse on network side
Transformer diameter
Tripping classes
Short-circuit protection
Control unit
Supply voltage
Reverse polarity protection
Inputs
Parametric assignment
Addressing
LEDs
24 V DC
yes
6 digital inputs 24 V DC
1 PTC input
3 relay outputs relay
1 digital output transistor
1 for ABB FieldBusPlug
1 for UMC100-PAN control station
1 for expansion module
via fieldbus, control station and / or software
Control station or addressing set
3 LEDs: green, yellow, red
Environment and mechanical data
Fastening
Dimensions (W x H x D)
Weight
Terminal cross-section
on DIN busbar (EN50022-35) or with 4 screws x M4
70 x 105 x 110 mm (incl. FieldBusPlug and control panel)
0.39 kg
max. 2.5 mm² or 2 x 1.5 mm²
Outputs
Interfaces
10
I/O-expansion modules DX111 / DX122
Expansion modules to increase the number of I/Os of a UMC100-FBP. Easy use of inputs by parametrizing for fault or warning; individual message on operator panel configurable.
Outputs
Fastening
Dimensions (W x H x D)
DX111
DX122
24 V DC
8 digital inputs 24 V DC
8 digital inputs 110/230 V AC
4 relay outputs relay
1 analogue output, 0/4 to 20 mA / 0 to 10 V configurable
on DIN busbar (EN50022-35)
45 x 77 x 100 mm (without terminal block)
2CDC135025C0201
Supply voltage
Inputs
ABB | 10/3
Motor control and protection
Technical data
NEW
Voltage expansion modules
Measures the 3 phase voltages of a motor. Different versions for use in grounded and ungrounded networks.
Supply voltage
Inputs
VI150
VI155
Outputs
Fastening
Dimensions (W x H x D)
24 V DC
3 analogue inputs 150 - 690 V AC
For use in grounded networks
Maximum operation altitude 2000 m
3 analogue inputs 150 - 690 V AC
For use in all networks
Maximum operation altitude > 2000 m
1 relay output
on DIN busbar (EN50022-35)
22.5 x 77 x 100 mm (without terminal block)
Control panel UMC100-PAN
Installation on the device or on the switching cabinet door
Graphics-enabled and backlit display, 3 LEDs for status indication
Freely configurable error messages
Multilingual: German, English, French, Italian, Portuguese, Spanish, Russian
10
MTQ22 - UMC100 and Ethernet
2CDC135025C0201
Ethernet connectivity for up to four UMC100
Modbus TCP protocol
Supports all network topologies
Star
Bus
Ring with redundancy (MRP protocol)
No special Ethernet connectors requried in MCCs
Easy to use in widthdrawable applications
10/4 | ABB
Notes
2CDC135025C0201
10
ABB | 10/5
Summary_11
11
11/0 | ABB
Self resetting current limiting module
S800-SCL-SR
Ordering details
11/2
Technical data
11/3
Summary_11
11
ABB | 11/1
2CCC413380F0001
S800-SCL-SR
Self-resetting current limiting module
S800S-SCL-SR
Description
S800-SCL-SR is ABB’s innovative self-resetting current limiting module which considerably
increases the short-circuit breaking capacity of downstream manual motor starters and high
performance MCBs. S800-SCL-SR is a self resetting current limiting module based on the
S800 technology.
It limits the short-circuit current until the downstream means of protection trips. Its current
continuity makes it as the ideal solution for group protection: All parallel branches remain
operative. This leads to an Expanded application range of the low voltage switchgear whose
short-circuit capabilities are usually limited. S800-SCL-SR can be combined with S800S high
performance MCB or with manual motor starters. S800-SCL-SR can also back up a single
circuit breaker or a group of circuit breakers or motor starters (group protection). Terminals and
outside dimensions are identical to the S800 range.
2CCC413381F0001
Ordering details
S803W-SCL-SR
11
Self-resetting
Type designation
Product number
EAN number
short-circuit limiter
IEC version
[A]
7612271
1-pole
32
S801S-SCL32-SR
2CCS801901R0539 412012
63
S801S-SCL63-SR
2CCS801901R0599 412036
100
S801S-SCL100-SR 2CCS801901R0639 411992
Weight Pack.
[kg] unit
0.25
0.25
0.25
1
1
1
2-pole
32
63
100
S802S-SCL32-SR
2CCS802901R0539 412074
S802S-SCL63-SR
2CCS802901R0599 412098
S802S-SCL100-SR 2CCS802901R0639 412050
0.5
0.5
0.5
1
1
1
3-pole
32
63
100
S803S-SCL32-SR
2CCS803901R0539 411930
S803S-SCL63-SR
2CCS803901R0599 411947
S803S-SCL100-SR 2CCS803901R0639 411954
0.75
0.75
0.75
1
1
1
Self-resetting
Type designation
Product number
EAN number
short-circuit limiter
IEC/UL version
[A]
7612271
3-pole
32
S803W-SCL32-SR 2CCS803917R0539 412319
63
S803W-SCL63-SR 2CCS803917R0599 412326
100
S803W-SCL100-SR 2CCS803917R0639 412302
Weight Pack.
[kg] unit
0.75
0.75
0.75
1
1
1
Main dimensions mm, inches
76.50
26.50
53
79.50
6
35
46
S800S-SCL-SR/S803S-SCL
S803W-SCL-SR
11/2 | ABB
46
76.50
2CCC413012B0201
6
45
95
142
79.50
45
95
53
35
26.50
S800S-SCL-SR/S803W-SCL-SR
Technical data
S800S-SCL-SR
[A]
32, 63, 100
Rated operational current Ie
Pole
1, 2, 3
Rated operational voltage Ue
(AC) according to IEC 60947-2
50/60 Hz [V]
400/690
(AC) according to UL 508
50/60 Hz [V]
[V]
690
Rated insulation voltage U i
[kV]
8
Rated impulse withstand voltage Uimp
Rated ultimate short-circuit breaking capacity
Icu = Ics according to IEC 60947-2 *
(AC) 50/60 Hz 240/415 V
[kA]
100
(AC) 50/60 Hz 254/440 V
[kA]
100
(AC) 50/60 Hz 277/480 V
[kA]
65
(AC) 50/60 Hz 289/500 V
[kA]
65
(AC) 50/60 Hz 346/600 V
[kA]
65
(AC) 50/60 Hz 400/690 V
[kA]
50
Short-circuit rating according to UL 508, CSA 22.2 *
(AC) 50/60 Hz 480 V
[kA]
65
(AC) 50/60 Hz 600 V
[kA]
65
S803W-SCL-SR
32, 63, 100
3
690
600
690
8
100
100
65
65
65
50
65
65
*) Valid only for approved combinations
Rated frequency
[Hz]
50/60
Mounting position any
Connections Cu
1 … 50 rigid (solid/stranded)
[mm 2]
1 … 70 flexible
[mm2]
Tightening torque
[Nm]
min. 3 / max. 4
[in. lbs.]
Feeding optional
Mouting on DIN top hat rail
EN 60715
Ambient air temperature
[°C]
–40 … +70
Storage temperature
[°C]
–40 … +85
Degree of protection
IP20
Classification acc. to NF F 16-101, NF F 16-102
I3, F2
Damp Heat
IEC 60068-2-30, 55 °C / 95 % r.h.
Vibration
IEC 60068-2-6, 5–10 Hz /
3 mm and 10–500 Hz /
2 g at 0.5 x Ie
Random Vibration
IEC 60068-2-64, 5–500 Hz / 2 g at 0.5 x Ie
0.5 x Ie
Resistance to climatic conditions
IEC 60068-2-1 /-2-2 /-2-30
Standard
IEC 60947-2
IEC 60947-4-1
50/60
any
1 … 50 rigid (solid/stranded)
1 … 70 flexible
14–1 AWG
min. 3 / max. 4
min. 26.5 / max. 25
optional
EN 60715
–40 … +70
–40 … +85
IP20
I3, F2
IEC 60068-2-30, 55 °C / 95 % r.h.
IEC 60068-2-6, 5–10 Hz /
3 mm and 10–500 Hz /
2 g at 0.5 x Ie
IEC 60068-2-64, 5–500 Hz / 2 g at
11
IEC 60068-2-1 /-2-2 /-2-30
IEC 60947-2
IEC 60947-4-1
UL 508, CSA 22.2 No. 14
Internal resistance at 25°C ambient temperature and nominal power losses
Rated current In
Internal resistance R i
Power losses Pvn
[A]
[mΩ/pole] [W/pole]
32
2.8
3.6
63
1.3
5.7
100 0.7 7.8
Rated current In [A] 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C 65°C 70°C
32 38.2 37.2 35.8 35.2 34.2 33.3 32
30.7
29.8
28.8
27.8
26.5
25.1
63 75.3 73.2 70.6 69.3 67.4 65.5 63
60.5
58.6
56.7
54.8
52.3
49.8
100
119.5
116.2
112 110 107 104 100 96 93 90 87 84 80
ABB | 11/3
2CCC413012B0201
Influence of ambient temperature – single mounted devices
S800-SCL-SR
Technical data
Short circuit breaking capacity
S800S-SCL-SR
S803W-SCL-SR
Rated ultimate short-circuit breaking capacity
I cu = Ics according to IEC 60947-2
(AC) 50/60 Hz 240/415 V
[kA]
100
100
(AC) 50/60 Hz 254/440 V
[kA]
100
100
(AC) 50/60 Hz 277/480 V
[kA] 65 65
(AC) 50/60 Hz 289/500 V
[kA] 65 65
(AC) 50/60 Hz 346/600 V
[kA] 65 65
(AC) 50/60 Hz 400/690 V
[kA] 50 50
Short-circuit rating according to UL 508, CSA 22.2
(AC) 50/60 Hz 480 V
[kA] 65
(AC) 50/60 Hz 600 V
[kA] 65
Coordination
Type 500 V AC 690 V AC
Fuse Current Limiter Fuse Current Limiter
Ics Icu gG, aM
S803x-SCL-SR
Ics Icu gG, aM
S803x-SCL-SR
kA kA kA A kA A kA kA kA A kA A
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0 No back-up required No back-up required
MS132-1.6
MS132-2.5 20 20 100 35 65* 32, 63,100
3
3
80 35 50** 32, 63,100
MS132-4.0 20 20 100 63 65* 32, 63,100
3
3
80 63 50** 32, 63,100
MS132-6.3 20 20 100 100 65* 32, 63,100
3 3 80 100 50** 32, 63,100
MS132-10 20 20 100 100 65* 32, 63,100
3 3 80 100 50** 32, 63,100
MS132-12 20 20 100 125 65* 32, 63,100
3
3
80 125 50** 32, 63,100
MS132-16 20 20 100 125 65* 32, 63,100
3
3
80 125 50** 32, 63,100
MS132-20 20 20 100 125 65* 32, 63,100
3
3
80 125 50** 32, 63,100
MS132-25 10 10 100 125 65* 63,100
3 3 80 125 50** 63,100
MS132-32 10 10 100 125 65* 63,100
3 3 80 125 50** 63,100
* 100 kA on request
** 80
kA on request
11/4 | ABB
2CCC413012B0201
11
Type 230
V AC 400
V AC 440
V AC
Fuse Current Limiter Fuse Current Limiter Fuse Current Limiter
Ics Icu gG, aM
S803x-SCL-SR
Ics Icu gG, aM
S803x-SCL-SR
Ics Icu gG, aM
S803x-SCL-SR
kA kA kA A kA A kA kA kA A kA A kA kA kA A kA A
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0 No back-up required No back-up required No back-up required
MS132-1.6
MS132-2.5 20
20
100
35
100
32, 63,100
MS132-4.0 20
20
100
63
100
32, 63,100
MS132-6.3 20
20
100
100
100
32, 63,100
MS132-10 20
20
100
100
100
32, 63,100
MS132-12 20
20
100
125
100
32, 63,100
MS132-16 20
20
100
125
100
32, 63,100
MS132-20 20
20
100
125
100
32, 63,100
MS132-25 50 50 100 125 100 63,100
50 50 100 125 100 63,100
20 20 100 125 100 63,100
MS132-32 25 50 100 125 100 63,100
25 50 100 125 100 63,100
20 20 100 125 100 63,100
S800-SCL-SR and S803S-SCL
Technical data
Installation requirements
The total sum of the rated currents of all downstream motor starters or circuit breakers shall not exceed the rated
current of the S800-SCL-SR. Furthermore the sum of all load currents including inrush currents shall not exceed the
maximum permissible load of the S800-SCL-SR.
Maximum load
10 000
1000
10
1
11
0.1
0.01
1
10
n x Ie
100
Multiple of the rated operational current Ie
2CCC413012B0201
Time in s time [s]
100
ABB | 11/5
Summary_12
12
12/0 | ABB
General technical data
General technical data
Coordination with short-circuit protection devices
12/2
Standards, specifications and certifying organizations
12/4
Terms and technical definitions
12/6
Standards and utilization categories
12/8
Degrees of protection
12/10
Climatic withstand of devices
12/11
Summary_12
12
ABB | 12/1
Coordination with short-circuit protection devices
In compliance with standards IEC 60947-4-1 and EN 60947-4-1, we define for the contactors and starters the type, rating
and characteristics of the short-circuit protection devices SCPD which allow selective protection against overloads and ensure
protection against short circuits.
Basic functions
Any starter is designed to:
–– start motors,
–– ensure continuous functioning of motors,
–– disconnect motors from the supply line,
–– guarantee protection of motors against overloads.
The starter is typically made up of a switching device (contactor) and an overload protection device (thermal overload relay or electronic overload
relay).
These two devices MUST be coordinated with equipment capable of providing protection against short circuit (SCPD: short circuit protective device): typically a circuit breaker with magnetic release only or a switch fuse. These are not necessarily part of the starter.
Applicable standards
IEC 60947-4-1 (EN 60947-4-1) precisely defines the different points to be considered in order to carry out correct coordination.
Complete coordination for a combination includes the following points:
–– Selectivity test between the overload relay and the short-circuit protection device SCPD.
–– Short-circuit condition tests:
-- at prospective "r" currents - These currents depend on the rated operational current of the starter (Ie AC-3) and are given by the standard
(Table 13). For example:
r = 1kA for Ie AC-3 < 16 A
r = 3 kA for 16 A < Ie AC-3 < 63 A
r = 5 kA for 63 A < Ie AC-3 < 125 A etc.
-- at the rated conditional short-circuit current "Iq" - This is the maximum prospective current that the combination can withstand, for example
50 kA.
Types of coordination
IEC 60947-4-1 (EN 60947-4-1) defines two types of coordination according to the expected level of service continuity. Acceptable extreme damage for the switchgear is divided into two types.
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not be able to then operate without
being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards.
The risk of contacts light welding is acceptable. In this case, the manufacturer must stipulate the measures to be taken with respect to
maintenance of the equipment.
The complete ABB offer
ABB has acquired years of experience with respect to problems of coordination and is able to make a complete offer based on tests performed in
its qualified laboratories. This offer includes 400 V, 500 V, 690 V networks.
A complete data base of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1), is available on the ABB Website.
In the coordination tables the following short-circuit protection devices are recommended:
–– Moulded case circuit-breakers (MCCBs)
–– Miniature circuit-breakers (MCBs)
–– Switch-disconnector-fuses (aM, gG and BS)
–– Manual Motor Starters (MMS).
General remarks applicable to all tables
–– Each table is defined for a maximum ambient temperature of 40 °C. For higher temperatures, apply a derating factor according to the following
rules:
-- Fuses: factor of 0.8 applied to In for an ambient temperature of 70 °C
-- MCCBs and MCBs: factor of 0.8 applied to In for an ambient temperature of 60 °C
-- The starter derating factor depends on the operating conditions of thermal overload relays:
Factor of 0.9 applied to In for an ambient temperature of 70 °C.
–– Each table is defined for motor currents: 3-phase motors, 4-pole
–– Normal starting means a starting time < 2 s. - Difficult starting means an accelerating time 10 s < ts < 30 s
Tripping classes of thermal overload relays according to IEC 60947-4-1 (EN 60947-4-1): 10A and 10
Tripping classes of electronic overload relays according to IEC 60947-4-1 (EN 60947-4-1): 10E, 20E, 30E selectable
–– In the tables with MCCBs, these are fitted with the magnetic relay alone. Setting is always carried out at > 12.3 Ie AC-3 so that the transient
current peak occurring during starting does not lead to tripping.
12/2 | ABB
1SBC101590S0201 - Rev. A
12
Coordination with short-circuit protection devices
A complete data base of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1) or UL 508 / UL 60947-4-1, is available on the ABB
Website: see below.
Selection
Simple or multiple selections all from the same screen.
Short-circuit protection devices
–– Air circuit breakers
–– Fuses "gG" or "aM"
–– Miniature circuit breaker
–– Moulded case circuit breaker
–– Manual motor starter
Starter type
–– Direct-on-line normal start
–– Direct-on-line heavy duty
–– Star-delta normal start
–– Soft starter normal start
Coordination
–– IEC type 1 or type 2
–– UL type A to Type F
Results
–– Search results displayed at the bottom of the selection page.
–– Only the most appropriate solutions to your application, will be displayed at the bottom of the page.
"Enable Smart Current Search" function featured for the short-circuit current where "near to" selected values also are included in the result.
–– Possible to print the page to a pdf file or from your printer.
–– "Clear selection" function to deselect all selected.
Access
To find the coordination tables for motor protection, please see:
www.abb.com/lowvoltage then go to the right menu: "Support", select: "Online Product Selection Tools" then select "Coordination Tables for
motor protection"
ABB | 12/3
1SBC101591S0201 - Rev. A
12
Standards, specifications and certifying organizations
Definitions
ABB low voltage devices are developed and manufactured in accordance with the applicable regulations as stated in the international IEC
standards, the European EN standards and the national ones such as
NF, DIN, GB and BS. For devices installed in ships, an approval issued
by independent classification societies is demanded by the maritime
insurance companies.
CE Marking:
CE marking indicates that the marked equipment conforms to the
relevant EU directive.
CE marking is part of an administrative procedure and guarantees free
movement of the product within the European Community.
Standards in Canada and the USA
Certification Body certificates (CB certificates) are available to prove the
complete conformity to standards
The IEC CB (Certification Body) scheme is multilateral agreement between the National Certification Bodies to allow international certification of electrical and electronic products so that a single certification
allows worldwide market access.
The CB Scheme was established by the International Electrotechnical
Committee for conformity testing to standards for electrical equipment
(IECEE).
Canadian and American specifications are more or less equivalent but
differ greatly from IEC standards.
UL Underwriters Laboratories USA
CSA Canadian Standard Association Canada
UL (USA) specifications make the following distinction between devices:
Listed Product
A product that has been produced under UL's listing and
follow-up service program in accordance with the terms of UL's
service agreement and that bears the UL listing mark as the
manufacturer's declaration that the product complies with UL's
requirements.
Certified products
In some cases, products are validated and tested according to a standard by a certification body and the manufacturer is regularly visited by
this body in order to check the respect of the design and the materials
used. This process creates a certified product. This is the case of UL
(Underwriters Laboratories) and CSA (Canadian Standard Association)
for instance (see below).
Recognized Component
A part or subassembly covered under UL's recognition service
and intended for factory installation in listed (or other) products.
Recognized components are incomplete in certain construction features or restricted in performance capabilities and not
intended for separate installation in the field, rather they are
intended for use as components of incomplete equipment
submitted for investigation by UL. Final acceptance of the component in the complete equipment is dependent upon its installation and use in accordance with all applicable use conditions
and ratings noted in the component report issued by UL, in
the guide information and in the individual client's Recognized
Component information page.
Specifications
International Specifications
The International Electrotechnical Commission, IEC, which is part of the
International Standards Organization, ISO, publishes IEC publications
which act as a basis for the world market.
European Specifications and National Specifications
The European committee for electrotechnical standardization (CENELEC), which groups together European countries, publishes EN standards.
12
These European standards may differ very little from IEC international
standards and have similar numbering.
The same applies for national standards which use, without exception,
the same numbering and reproduce the texts of these unified standards
in their entirety. Contradicting national standards are withdrawn.
European Directives
The guarantee of the free movement of goods within the European
Community means that any regulatory differences between member
states have been eliminated. The European directives set up common
rules that are included in the legislation of each state while contradictory regulations are cancelled.
Three directives are essential:
–– Low Voltage Directive 2006/95/EC concerns electrical equipment
from 0 to 1000 V AC and from 0 to 1500 V DC.
This specifies that compliance with the requirements that it sets out is
acquired if the equipment conforms to the standards harmonized on an
European level. EN 60947-1 and EN 60947-4-1 for contactors.
–– Machinery Directive 2006/42/EC for safety specifications of machines and equipment on complete machines.
–– Electromagnetic Compatibility Directive 2004/108/EC which concerns all devices able to create electromagnetic disturbance.
12/4 | ABB
The combined UL signs for the USA and Canada are recognized by the
authorities of both countries.
Compulsory China Certification (CCC): The CCC mark is a compulsory certification mark in the field of safety for products sold on the
Chinese market.
GOST / EAC: Russia (please consult your local ABB sales office)
C-Tick: The C-Tick mark certifies compliance with the Australian EMC
requirements. The mark is also recognized in New Zealand
ANCE: Mexico
Marine Approvals
The following specifications must be respected when these devices are
used on ships:
BV
Bureau Veritas France
DNV
Det Norske Veritas Norway
GL
Germanischer LIoyd Germany
LRS
LIoyd's Register of Shipping Great Britain
ABS
America Bureau of Shipping
RMRS Russian Maritime Register of Shipping RMRS
RRR
Russian River Register
MRS
Maritime Register of Shipping Russia
PRS
Polski Rejestr Statkow Poland
RINA
Registro Italiano Navale Italy
1SBC101630S0201 - Rev. A
CB scheme
Standards, specifications and certifying organizations
Specifications (cont.)
International Standards
IEC 60947-1 Low-voltage switchgear and controlgear – Part 1: General
rules
IEC 60947-4-1 Low-voltage switchgear and controlgear – Part 4: Contactors and motor starters – Section 1: Electromechanical contactors
and motor starters
IEC 60947- 5-1 Low-voltage switchgear and controlgear – Part 5:
Control circuit devices and switching elements – Section 1: Electromechanical control circuit devices
IEC 60947-5-4 Low-voltage switchgear and controlgear – Part 5-4:
Control circuit devices and switching elements. Method of assessing
the performance of low-energy contacts. Special tests
IEC 60947- 6-1 Low-voltage switchgear and controlgear – Part 6:
Multiple function equipment – Section 1: Automatic transfer switching
equipment
IEC 60204-1 Electrical equipment of industrial machines – Part 1:
General requirements
IEC 60715 Dimensions of low-voltage switchgear and controlgear.
Standardized mounting on rails for mechanical support of electrical
devices in switchgear and controlgear installations
European Standards
EN 50 005 Low-voltage switchgear and controlgear for industrial use –
Terminal marking and distinctive number: General rules
(Annex L of IEC 60947-1).
EN 50 011 Low-voltage switchgear and controlgear for industrial use –
Terminal marking, distinctive number and distinctive letter for particular
contactor relays (Annex M of IEC 60947-5-1)
EN 60947-1 Low-voltage switchgear and controlgear – Part 1: General
rules.
EN 60947-4-1 Low-voltage switchgear and controlgear – Part 4: Contactors and motor starters – Section 1: Electromechanical contactors
and motor starters.
EN 60947-5-1 Low-voltage switchgear and controlgear – Part 5:
Control circuit devices and switching elements – Section 1: Electromechanical control circuit devices.
EN 60947-5-4 Low-voltage switchgear and controlgear – Part 5-4:
Control circuit devices and switching elements. Method of assessing
the performance of low-energy contacts. Special tests.
12
EN 60947- 6-1 Low-voltage switchgear and controlgear – Part 6:
Multiple function equipment – Section 1: Automatic transfer switching
equipment.
EN 60204-1 Electrical equipment of industrial machines – Part 1: General requirements.
EN 60 715 Dimensions of low-voltage switchgear and controlgear.
Standardized mounting on rails for mechanical support of electrical
devices in switchgear and controlgear installations.
National Standards
European countries national standards reproduce the corresponding EN... standards. Codification is built by addition of a prefix to EN
numbering.
1SBC101630S0201 - Rev. A
For instance:
–– France NF EN...
–– Germany DIN EN...
–– Great Britain BS EN...
–– Italy CEI EN...
–– Sweden SS EN...
ABB | 12/5
Terms and technical definitions
Circuits
Coordination of protections against short circuit
–– auxiliary circuit: All the conductive parts of a contactor designed to
be inserted in a different circuit from the main circuit and the contactor control circuits.
–– control circuit: All the conductive parts of a contactor (other than the
main circuit and the auxiliary circuit) used to control the contactor's
closing operation or opening operation or both.
–– main circuit: All the conductive parts of a contactor designed to be
inserted in the circuit that it controls.
The goal here is to protect electromechanical starters and softstarters.
IEC 60947-4-1 defines tripping classes 10 A, 10, 20 and 30. Types
10 A, 10, etc. correspond to the maximum tripping time for a making
current at 7.2 times the setting current.
Furthermore, for each class the standard specifies the tripping time for
1.5 times the setting current and sets the non tripping condition at 1.05
times the setting current.
10 A
10
20
30
s
120
240
480
720
overload release: overload relay or release which operates in the case
of overload and also in case of loss of phase.
s
2 - 10
4 - 10
6 - 20
9 - 30
Extract from IEC 60947-4-1:
Tripping class
Max. tripping time for 1.5 times
Tripping time for 7.2 times
the setting current (cold state)
For 1.05 times the setting current
No tripping
Electromagnetic compatibility
AF... contactors comply with IEC 60947-1, 60947-4-1 and
EN 60947-1, 60947-4-1 standards.
Definitions:
Environment A: "Mainly relates to low-voltage non public or industrial
networks/locations/installations (EN 50082-2 article 4) including highly
disturbing sources".
Environment B: "Mainly relates to low-voltage public networks (EN
50082-1 article 5) such as residential, commercial and light industrial
locations/installations. Highly disturbing sources such as arc welders
are not covered by this environment".
12
The characteristics of the starter must comply with the international
standard IEC 60947-4-1 which defines the above items as follows:
contactor: a mechanical switching device having only one position of
rest, operated otherwise than by hand, capable of making, carrying and
breaking currents under normal circuit conditions including overload
conditions.
All these data are summarized in the table below.
the setting current (warm state)
The starter is typically made up of a switching device (contactor) and
an overload protection device (thermal overload relay or electronic
overload relay). These two devices MUST be coordinated with equipment capable of providing protection against short circuit (SCPD:
short circuit protective device): typically a circuit breaker with magnetic
release only or a switch fuse. These are not necessarily part of the
starter.
Notice for AF09 ... AF38, AF116 ... AF2650 contactors and NF contactor relays: these products have been designed for environment A. Use
of this product in environment B may cause unwanted electromagnetic
disturbances in wich case the user may be required to take adequate
mitigation measures.
circuit-breaker: defined by IEC 60947-2 as a mechanical switching
device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and
breaking currents under specified abnormal circuit conditions.
IEC publication 60947-4-1 defines coordination types "1" and "2":
–– Type "1" coordination requires that, in the event of a short-circuit, the
contactor or starter does not endanger persons or installations and
will not then be able to operate without being repaired or parts being
replaced.
–– Type "2" coordination requires that, in short-circuit conditions, the
contactor or starter does not endanger persons or installations and
will be able to operate afterwards. The risk of contacts being light
welded is acceptable. In this case, the manufacturer must stipulate
the measures to be taken with respect to maintenance of the equipment.
Rated operational current Ie.
Current rated by the manufacturer. It is mainly based on the rated
operational voltage Ue, the rated frequency, the utilization category, the
rated duty and the type of protective enclosure, if necessary.
AF40 ... AF96 have been designed for environment B.
Conventional free air thermal current Ith
Definitions according to SEMI F47-0706
Current that the contactor can withstand in free air for a duty time of
8 hours without the temperature rise of its various parts exceeding the
maximum values given by the standard.
SEMIF47-0706 defines the voltage sag immunity required for semiconductor processing, metrology and automated test equipment, and on
subsystems and components which are used in the construction of
semiconductor processing equipment including but not limited to:
–– Power supplies
–– Generators
–– Robots and factory interface
–– Chillers, pumps, blowers
–– AC operated contactors and contactor relays
–– ...
voltage sag: an rms reduction in the AC voltage, at the power frequency, for durations from a half cycle to a few seconds.
The IEC terminology for this phenomenon is voltage dip.
voltage sag immunity: the ability of equipment to withstand momentary electrical power interruptions or sags
12/6 | ABB
Operating cycle or cycle
Includes one making operation and one breaking operation.
Cycle time
This is the sum of the current flow time and the no-current time for
given cycle.
Electrical durability
Number of on-load operating cycles that the contactor is able to carry
out. It depends on the operational current, the operational voltage and
the utilization category.
1SBC101625S0201 - Rev. A
Thermal overload relay tripping classes
Any starter is designed to:
–– start motors,
–– ensure continuous functioning of motors,
–– disconnect motors from the supply line,
–– guarantee protection of motors against overloads.
Terms and technical definitions
Mechanical durability
Ambient temperature
Number of no-current operating cycles that a contactor is able to carry
out.
Air temperature close to the contactor.
Assessed failure rate
–– Time constant: Ratio of the inductance to the resistance
(L/R = mH/Ω = ms).
–– Short-time withstand current: Current that the contactor is able to
withstand in closed position for a short time interval and in specified
conditions.
–– Closing time: Time interval between the coil energization and the
instant the contacts touch on all the poles.
–– Opening time: Time interval between the coil de-energization and the
instant the contacts separate on all the poles.
Defined according to IEC 60947-5-4. This rate is given in standard
industrial environments for the contactor relays and for the built-in
auxiliary contact of contactors.
Load factor
Ratio of the on-load operating time to the total cycle time x 100.
Time
Switching frequency
Number of switching cycles per hour.
Rated control voltage Uc
Control voltage value for which the control circuit is sized.
Plugging
Stopping or fast reversal in rotation direction of a motor by two supply
leads being interchanged while the motor is running.
Rated operational voltage Ue
Voltage to which the contactor's utilization characteristics refer. In
three-phase it is the phase-to-phase voltage.
Inching
Energization of a motor's circuit repeatedly or for short periods with the
aim of obtaining small movements of the driven mechanism.
Rated insulation voltage Ui
Coil operating limits
Rated impulse withstand voltage Uimp
Expressed in multiples of the nominal control circuit voltage Uc for the
upper and lower limits.
Mounting position
Comply with the manufacturer's instructions. Restrictions are to be
taken into account for certain mounting positions.
Reference voltage for dielectric tests and creepage distances.
Peak value of an impulse voltage, having a specified form and polarity,
which does not cause breakdown in specific test conditions.
Shock withstand
Requirement for vehicles, crane drives, installations on board ships and
plug-in equipment. For the acceptable "g" values, the contacts must
not change position and the thermal overload relays must not trip.
Rated breaking or making capacity
Root mean square (r.m.s.) value of the current that the contactor is able
to break or make at a given voltage according to the conditions specified by standards and for a given utilization category.
Resistance to vibrations
Requirements for vehicles, boats and other means of transport. For
the specified vibration amplitude and frequency values the device must
remain able to operate.
12
Intermittent duty
1SBC101625S0201 - Rev. A
Duty during which the contactor is successively closed or open for
periods which are too short to enable the contactor to achieve thermal
balance.
ABB | 12/7
Standards and utilization categories
Utilization categories:
A contactor's duty is characterised by the utilization category together with the rated operational voltage and current indicated.
Utilization categories for contactors according to IEC 60947-4-1:
Alternating current:
Direct current:
AC-1
AC-2
AC-3
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
DC-6
Non-inductive or slightly inductive loads, resistance furnaces.
Slip-ring motors: starting, switching off.
Cage motors: starting, switching off running motors.
Cage motors: starting, plugging, inching.
Discharge lamp switching.
Incandescent lamp switching.
Transformer switching.
Capacitor bank switching.
Hermetic refrigeration compressor motor control with manual resetting of overload releases.
Hermetic refrigeration compressor motor control with automatic resetting of overload releases.
Non inductive or slightly inductive loads, resistance furnaces.
Shunt motors: starting, plugging, inching, dynamic breaking of DC motors.
Series motors: starting, plugging, inching, dynamic breaking of DC motors.
Incandescent lamp switching.
Utilization categories for contactor relays according to IEC 60947-5-1:
Alternating current:
Direct current:
AC-12
AC-13
AC-14
AC-15
DC-12
DC-13
DC-14
Control
Control
Control
Control
Control
Control
Control
of
of
of
of
of
of
of
resistive loads and static loads with opto-coupler isolation.
static loads with transformer isolation.
weak electromagnetic loads (≤ 72 VA).
electromagnetic loads (> 72 VA).
resistive loads and static loads with opto-coupler isolation.
DC electromagnets.
DC electromagnets having economy resistors.
In fact some applications, and the specific criteria characterizing the various loads controlled by contactors, may modify the utilization characteristics of the contactors. The main applications concerned are:
Capacitor bank switching
Account must be taken of high peaks when the current is made and of harmonic currents during continuous duty. For this application, IEC publication 60947-4-1 stipulates utilization category AC-6b. The operational currents or powers acceptable for the contactors are determined by our
electrical tests; IEC publication 60947-4-1 gives the calculating formula for determining the operational current (Table 9).
Transformer switching
Account must be taken of the peaks due to magnetization phenomena when the current is made.
For this application, IEC publication 60947-4-1 stipulates utilization category AC-6a. The operational currents or powers acceptable for the contactors are determined using the values obtained for AC-3 or AC-4 category tests and the calculating formula given in IEC 60947-4-1 (Table 9).
Lighting circuit switching
The current peaks occurring on energization of the circuit and the power factor depend on the type of lamps, the connection mode and whether
or not there is compensation.
For this application, IEC publication 60947-4-1 stipulates two standard utilization categories:
–– AC-5a for discharge lamp switching.
–– AC-5b for incandescent lamp switching.
Slip-ring motor switching
The contactors used for short-circuiting rotor resistors can be used for rotor voltages up to 2 times the rated operational voltage.
The conditions of use of rotor contactors depend on the connection mode of the main poles. IEC 60947-4-1 stipulates AC-2 utilization category
for startor contactor.
1SBC101626S0201 - Rev. A
12
12/8 | ABB
Standards and utilization categories
Utilization categories (cont.)
DC power circuit switching
Arc suppression is more difficult in direct current than in alternating current. Higher the time constant and voltage, heavier the breaking conditions:
consequently several poles have to be connected in series.
AC high current circuit switching
Possibility of increasing performances by connecting poles in parallel.
Circuit switching during temporary and intermittent duty
In these cases higher operational currents are acceptable.
Influence of the length of the conductors used in the contactor control circuit
According to the operational voltages, the cross-sectional areas, the coil consumption and the control layout, difficulties due to line resistances
and capacitances may appear during contactor closing and opening orders.
Making and breaking conditions for utilization categories
Utilization category
Durability test conditions
Making conditions
I/Ie
U/Ue
Cos. ϕ
or
L/R (ms)
Breaking conditions
I/Ie
U/Ue
Cos. ϕ
or
L/R (ms)
Occasional operation
Making and breaking capacities - 50 operating cycles
Making conditions
Breaking conditions
Ic/Ie
Ur/Ue
Ic/Ie
Ur/Ue
Cos. ϕ
or
L/R (ms)
Cos. ϕ
or
L/R (ms)
Contactors for AC circuit switching
AC-1
AC-2
AC-3
AC-4
Ie
17 < Ie
Ie
Ie
17 < Ie
Ie
< 17
< 100
> 100
< 17
< 100
> 100
A
A
A
A
A
A
1
2.5
6
6
6
6
6
6
1
1
1
1
1
1
1
1
0.95
0.65
0.65
0.35
0.35
0.65
0.35
0.35
1
2.5
1
1
1
6
6
6
1
1
0.17
0.17
0.17
1
1
1
0.95
0.65
0.65
0.35
0.35
0.65
0.35
0.35
1.5
4
10
10
10
12
12
12
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
0.8
0.65
0.45
0.45
0.35
0.45
0.45
0.35
1.5
4
8
8
8
10
10
10
1.05
1.05
1.05
1.05
1.05
1.05
1.05
1.05
0.8
0.65
0.45
0.45
0.35
0.45
0.45
0.35
1
1
1
1
2
7.5
1
2.5
2.5
1
1
1
1
2
7.5
1.5
4
4
1.05
1.05
1.05
1
2.5
15
1.5
4
4
1.05
1.05
1.05
1
2.5
15
–
0.7
–
1
–
1
–
0.4
6
10
1.1
1.1
0.7
0.3
6
10
1.1
1.1
0.7
0.3
T0.95
6 P(1)
–
Occasional operation
Making and breaking capacities - 50 operating cycles
Making conditions
Breaking conditions
Ic/Ie
Ur/Ue
T0.95
Ic/Ie
Ur/Ue
1.1
1.1
6 P(1)
1.1
1.1
10
1.1
15 ms
10
1.1
Contactors for DC circuit switching
1
2.5
2.5
DC-1
DC-3
DC-5
12
Contactor relays for AC circuit switching
AC-14
AC-15
(≤ 72 VA)
(> 72 VA)
–
10
–
1
Contactor relays for AC circuit switching
Utilization category
Standard operation
DC-13
DC-14
Making conditions
I/Ie
U/Ue
1
1
–
–
T0.95
6 P(1)
–
Breaking conditions
I/Ie
U/Ue
1
1
–
–
T0.95
6 P(1)
15 ms
Key:
U (I)
= applied voltage (current)
Ur
= recovery voltage
L/R
= test circuit time constant
Ue (Ie) = rated operational voltage (current)
Ic
=m
aking and breaking current expressed in DC or in AC like
the r.m.s. value of the symmetrical components
T0.95
= t ime required to reach 95% of the current in steady-state
conditions, expressed in milliseconds
ABB | 12/9
1SBC101626S0201 - Rev. A
(1) T
he value "6 x P" is the result of an empirical relation which is estimated to represent most DC magnetic loads up to the highest limit of P = 50 W (6 x P = 300 ms). It is accepted
that loads having drawn energy above 50 W are made up of weaker loads in parallel. As a consequence, the 300 ms value must form the highest limit whatever the value of the
power drawn.
Degrees of protection
General
In an installation, the degree of protection required for electrical equipment depends on the environmental characteristics. The degree of protection, ensured by the enclosure of equipment or by the cubicle containing the equipment is expressed by the IP code which gives the level of protection against access to hazardous parts, the ingress of foreign bodies and/or the ingress of water, in compliance with IEC 60529, IEC 60947-1.
Besides the IP symbol, the complete code has two figures followed (optionally) by two additional letters. A short description of the elements used
in IP coding is given below.
IP... code
Figures
or letters
Specifications for installation protection
Protection of persons
0
1
2
3
4
5
6
Against ingress of foreign bodies
No protection
Diameter > 50 mm
Diameter > 12.5 mm
Diameter > 2.5 mm
Diameter > 1 mm
Limited protection against dust
Total protection against dust
Against access to hazardous parts with:
No protection
Back of hand
Finger
Tool
Wire
Wire
Wire
0
1
2
3
4
5
6
7
8
Against entrance of water having a harmful effect
No protection
Vertical dripping
Dripping at a vertical angle of < 15°
Rain at a vertical angle of < 60°
Splashing
Low pressure water jet
Powerful water jets
Temporary immersion
Permanent immersion
A
B
C
D
Against ingress of foreign bodies
Stopped by a barrier with a 50 mm Ø sphere
Entrance of test finger limited to 80 mm
Wire with 2.5 mm Ø and length of 100 mm
Wire with 1 mm Ø and length of 100 mm
H
M
S
W
Specific additional information
High voltage apparatus
Moving parts which are moving during water test
Moving parts which are stationary during water test
Specified atmospheric conditions
First figure
Second figure
Additional letter (optional) for use with:
First figure 0
First figure 0 or 1
First figure 1 or 2
First figure 2 or 3
Additional letter (optional)
Against access to hazardous parts with:
Back of hand
Finger
Tool
Wire
–
Note: The type of enclosure or cubicle in which the equipment must be installed prevails with respect to the degree of protection.
1SBC101627S0201
12
12/10 | ABB
Climatic withstand of devices
The life time of devices are mainly influenced by series of climatic factors which cause their corrosion.
In practice, besides climatic conditions, there are other factors which may damage equipment such as fungi, insects (termites), dust, work site dirt
and aggressive environment (salty or sulphurous atmosphere, etc.) which can often only be identified at the place of installation.
Climatic stress, definitions and test conditions are dealt with in national publications such as the DIN 50 series and UTE 63-100 publication which
are attached to international publications such as IEC 60068.
The test conditions are:
Description
Symbolization
Time of one cycle
Cycle phase time
Humidity
and
variable
temperature
IEC 60068-2-30
Test Db
24 hours
12 hours including
rise in temperature
12 hours including
cooling (open device)
Temperature
in test chamber
40 °C
Relative humidity
25 °C
95 %
95 %
ABB contactors have been used for many years in the most countries, with hot and humid climates for example: Brazil, Indonesia, India or on
ships. Experience has shown that ABB devices can be used in most countries throughout the world.
The climate of the country in which the apparatus is installed is not the determining choice factor.
Account must be taken of:
–– the immediate environment of the devices (sheltered, ventilated, temperature),
–– the aggressivity of the immediate atmosphere at the place of installation,
–– the length and frequency of non operating periods.
In the case of frequent condensation (i.e. the formation of condensation caused by rapid changes in temperature), heating resistors must be
installed in cubicles (100 to 250 W per m³ of enclosure).
The table below gives the cases where heating is necessary.
Environment
Inside
premises
Outside, sheltered
Outside or
by the seaside
No running water
no condensation
With running water
No running water
no condensation
With running water
Operating conditions
Climate
Internal heating
Continuous or not
All climates
of enclosure
Without
Continuous
Frequent or long stops
All climates
Temperate
Tropical
Temperate
Tropical
All climates
Temperate
Tropical
Without
Without
With
Without
With
Without
Without
With
Continuous or not
Continuous
Frequent or long stops
12
1SBC101628S0201
The entrance of dust, insects, dirt, etc. in devices may be prevented if the appropriate degree of protection according to IEC 60529 is chosen (See "Degree of protection" table).
ABB | 12/11
Index
Order code classification
13
Type
Page
1SAM101923R0002 MSMN
2/38
1SAM101923R0012 MSMNO
2/38
1SAM201901R1001 HKF1-11
2/15
1SAM201901R1002 HKF1-20
2/15
1SAM201902R1001 HK1-11
2/15
1SAM201902R1002 HK1-20
2/15
1SAM201902R1003 HK1-02
2/15
1SAM201902R1004 HK1-20L
2/15
1SAM201903R1001 SK1-11
2/15
1SAM201903R1002 SK1-20
2/15
1SAM201903R1003 SK1-02
2/15
1SAM201904R1001 UA1-24
2/16
1SAM201904R1002 UA1-48
2/16
1SAM201904R1003 UA1-60
2/16
1SAM201904R1004 UA1-110
2/16
1SAM201904R1005 UA1-230
2/16
1SAM201904R1006 UA1-400
2/16
1SAM201904R1007 UA1-415
2/16
1SAM201904R1008 UA1-208
2/16
1SAM201904R1009 UA1-575
2/16
1SAM201904R1010 UA1-20
2/16
1SAM201906R1102 PS1-2-0-65
2/20
1SAM201906R1103 PS1-3-0-65
2/20
1SAM201906R1104 PS1-4-0-65
2/20
1SAM201906R1105 PS1-5-0-65
2/20
1SAM201906R1112 PS1-2-1-65
2/20
1SAM201906R1113 PS1-3-1-65
2/20
1SAM201906R1114 PS1-4-1-65
2/20
1SAM201906R1115 PS1-5-1-65
2/20
1SAM201906R1122 PS1-2-2-65
2/20
1SAM201906R1123 PS1-3-2-65
2/20
1SAM201906R1124 PS1-4-2-65
2/20
1SAM201906R1125 PS1-5-2-65
2/20
1SAM201907R1101 S1-M1-25
2/20
1SAM201907R1102 S1-M2-25
2/20
1SAM201907R1103 S1-M3-25
2/20
1SAM201908R1001 BS1-3
2/20
1SAM201909R1001 FS116
2/20
1SAM201909R1021 MSAH1
2/38
1SAM201910R1001 AA1-24
2/16
1SAM201910R1002 AA1-110
2/16
1SAM201910R1003 AA1-230
2/16
1SAM201910R1004 AA1-400
2/16
1SAM201911R1010 IB132-G
2/22
1SAM201911R1011 IB132-Y
2/22
1SAM201912R1010 DMS132-G
2/22
1SAM201912R1011 DMS132-Y
2/22
1SAM201913R1103 S1-M3-35
2/20
1SAM201914R1001 PB1-1-32
2/20
1SAM201914R1002 S1-PB1-25
2/20
1SAM201916R1103 PS1-3-0-100
2/20
1SAM201916R1104 PS1-4-0-100
2/20
1SAM201916R1105 PS1-5-0-100
2/20
1SAM201916R1113 PS1-3-1-100
2/20
1SAM201916R1114 PS1-4-1-100
2/20
1SAM201916R1115 PS1-5-1-100
2/20
1SAM201916R1123 PS1-3-2-100
2/20
1SAM201920R1000 MSH-AR
2/38
1SAM201920R1001 MSHD-LB
2/38
1SAM201920R1002 MSHD-LY
2/38
1SAM201920R1011 MSHD-LTB
2/38
1SAM201920R1012 MSHD-LTY
2/38
1SAM250000R1001 MS116-0.16
2/4
1SAM250000R1002 MS116-0.25
2/4
1SAM250000R1003 MS116-0.4
2/4
1SAM250000R1004 MS116-0.63
2/4
1SAM250000R1005 MS116-1.0
2/4
1SAM250000R1006 MS116-1.6
2/4
1SAM250000R1007 MS116-2.5
2/4
1SAM250000R1008 MS116-4.0
2/4
1SAM250000R1009 MS116-6.3
2/4
1SAM250000R1010 MS116-10
2/4
1SAM250000R1011 MS116-16
2/4
1SAM250000R1012 MS116-12
2/4
1SAM250000R1013 MS116-20
2/4
1SAM250000R1014 MS116-25
2/4
1SAM250000R1015 MS116-32
2/4
1SAM250005R1001 MS116-0.16-HKF1-11 2/4
1SAM250005R1002 MS116-0.25-HKF1-11 2/4
1SAM250005R1003 MS116-0.4-HKF1-11 2/4
1SAM250005R1004 MS116-0.63-HKF1-11 2/4
1SAM250005R1005 MS116-1.0-HKF1-11 2/4
1SAM250005R1006 MS116-1.6-HKF1-11 2/4
1SAM250005R1007 MS116-2.5-HKF1-11 2/4
1SAM250005R1008 MS116-4.0-HKF1-11 2/4
1SAM250005R1009 MS116-6.3-HKF1-11 2/4
1SAM250005R1010 MS116-10.0-HKF1-11 2/4
1SAM250005R1011 MS116-16.0-HKF1-11 2/4
1SAM250005R1012 MS116-12.0-HKF1-11 2/4
1SAM250005R1013 MS116-20-HKF1-11 2/4
13/0 | ABB
Order code
Type
Page
1SAM250005R1014 MS116-25-HKF1-11 2/4
1SAM250005R1015 MS116-32-HKF1-11 2/4
1SAM301901R1001 CK1-11
2/15
1SAM301901R1002 CK1-20
2/15
1SAM301901R1003 CK1-02
2/15
1SAM340000R1001 MS132-0.16T
2/7
1SAM340000R1002 MS132-0.25T
2/7
1SAM340000R1003 MS132-0.4T
2/7
1SAM340000R1004 MS132-0.63T
2/7
1SAM340000R1005 MS132-1.0T
2/7
1SAM340000R1006 MS132-1.6T
2/7
1SAM340000R1007 MS132-2.5T
2/7
1SAM340000R1008 MS132-4.0T
2/7
1SAM340000R1009 MS132-6.3T
2/7
1SAM340000R1010 MS132-10T
2/7
1SAM340000R1011 MS132-16T
2/7
1SAM340000R1012 MS132-12T
2/7
1SAM340000R1013 MS132-20T
2/7
1SAM340000R1014 MS132-25T
2/7
1SAM350000R1001 MS132-0.16
2/5
1SAM350000R1002 MS132-0.25
2/5
1SAM350000R1003 MS132-0.4
2/5
1SAM350000R1004 MS132-0.63
2/5
1SAM350000R1005 MS132-1.0
2/5
1SAM350000R1006 MS132-1.6
2/5
1SAM350000R1007 MS132-2.5
2/5
1SAM350000R1008 MS132-4.0
2/5
1SAM350000R1009 MS132-6.3
2/5
1SAM350000R1010 MS132-10
2/5
1SAM350000R1011 MS132-16
2/5
1SAM350000R1012 MS132-12
2/5
1SAM350000R1013 MS132-20
2/5
1SAM350000R1014 MS132-25
2/5
1SAM350000R1015 MS132-32
2/5
1SAM350005R1001 MS132-0.16-HKF1-11 2/5
1SAM350005R1002 MS132-0.25-HKF1-11 2/5
1SAM350005R1003 MS132-0.4-HKF1-11 2/5
1SAM350005R1004 MS132-0.63-HKF1-11 2/5
1SAM350005R1005 MS132-1.0-HKF1-11 2/5
1SAM350005R1006 MS132-1.6-HKF1-11 2/5
1SAM350005R1007 MS132-2.5-HKF1-11 2/5
1SAM350005R1008 MS132-4.0-HKF1-11 2/5
1SAM350005R1009 MS132-6.3-HKF1-11 2/5
1SAM350005R1010 MS132-10.0-HKF1-11 2/5
1SAM350005R1011 MS132-16.0-HKF1-11 2/5
1SAM350005R1012 MS132-12.0-HKF1-11 2/5
1SAM350005R1013 MS132-20-HKF1-11 2/5
1SAM350005R1014 MS132-25-HKF1-11 2/5
1SAM350005R1015 MS132-32-HKF1-11 2/5
1SAM360000R1001 MO132-0.16
2/6
1SAM360000R1002 MO132-0.25
2/6
1SAM360000R1003 MO132-0.4
2/6
1SAM360000R1004 MO132-0.63
2/6
1SAM360000R1005 MO132-1.0
2/6
1SAM360000R1006 MO132-1.6
2/6
1SAM360000R1007 MO132-2.5
2/6
1SAM360000R1008 MO132-4.0
2/6
1SAM360000R1009 MO132-6.3
2/6
1SAM360000R1010 MO132-10
2/6
1SAM360000R1011 MO132-16
2/6
1SAM360000R1012 MO132-12
2/6
1SAM360000R1013 MO132-20
2/6
1SAM360000R1014 MO132-25
2/6
1SAM360000R1015 MO132-32
2/6
1SAM401901R1001 HK4-11
2/32
1SAM401901R1002 HK4-W
2/32
1SAM401902R1001 HKS4-11
2/32
1SAM401902R1002 HKS4-20
2/32
1SAM401902R1003 HKS4-02
2/32
1SAM401904R1001 SK4-11
2/32
1SAM401905R1001 UA4-110
2/32
1SAM401905R1002 UA4-230
2/32
1SAM401905R1003 UA4-400
2/32
1SAM401905R1004 UA4-24
2/32
1SAM401906R1001 UA4-HK-230
2/32
1SAM401906R1002 UA4-HK-400
2/32
1SAM401907R1001 AA4-24
2/32
1SAM401907R1002 AA4-110
2/32
1SAM401907R1003 AA4-230
2/32
1SAM401907R1004 AA4-400
2/32
1SAM401908R1001 KA450
2/35
1SAM401910R1001 TB450
2/35
1SAM401911R1001 PS4-2-0
2/35
1SAM401911R1002 PS4-3-0
2/35
1SAM401911R1003 PS4-4-0
2/35
1SAM401911R1004 PS4-2-2
2/35
1SAM401911R1005 PS4-3-2
2/35
1SAM401911R1006 PS4-4-2
2/35
1SAM401911R1007 S4-M1
2/35
1SAM401911R1008 BS4-3
2/35
Order code
Type
1SAM401912R1001 DX495
1SAM450000R1005 MS450-40
1SAM450000R1006 MS450-45
1SAM450000R1007 MS450-50
1SAM460000R1005 MO450-40
1SAM460000R1006 MO450-45
1SAM460000R1007 MO450-50
1SAM501901R1001 KA495
1SAM501902R1001 KA495C
1SAM550000R1007 MS495-63
1SAM550000R1008 MS495-75
1SAM550000R1009 MS495-90
1SAM550000R1010 MS495-100
1SAM560000R1007 MO495-63
1SAM560000R1008 MO495-75
1SAM560000R1009 MO495-90
1SAM560000R1010 MO495-100
1SAM580000R1004 MS497-32
1SAM580000R1005 MS497-40
1SAM580000R1006 MS497-50
1SAM580000R1007 MS497-63
1SAM580000R1008 MS497-75
1SAM580000R1009 MS497-90
1SAM580000R1010 MS497-100
1SAM590000R1004 MO496-32
1SAM590000R1005 MO496-40
1SAM590000R1006 MO496-50
1SAM590000R1007 MO496-63
1SAM590000R1008 MO496-75
1SAM590000R1009 MO496-90
1SAM590000R1010 MO496-100
1SAX101110R0001 DB16E
1SAX101910R1001 DB19EF
1SAX111001R1101 E16DU-0.32
1SAX111001R1102 E16DU-1.0
1SAX111001R1103 E16DU-2.7
1SAX111001R1104 E16DU-6.3
1SAX111001R1105 E16DU-18.9
1SAX121001R1101 EF19-0.32
1SAX121001R1102 EF19-1.0
1SAX121001R1103 EF19-2.7
1SAX121001R1104 EF19-6.3
1SAX121001R1105 EF19-18.9
1SAX201110R1001 DB45E
1SAX211001R1101 E45DU-30
1SAX211001R1102 E45DU-45
1SAX221001R1101 EF45-30
1SAX221001R1102 EF45-45
1SAX301110R1001 DB80E
1SAX301110R1002 DB140E
1SAX311001R1101 E80DU-80
1SAX321001R1101 E140DU-140
1SAX331001R1101 EF65-70
1SAX331001R1102 EF65-56
1SAX341001R1101 EF96-100
1SAX351001R1101 EF146-150
1SAX531001R1101 EF205-210
1SAX611001R1101 EF370-380
1SAX721001R1101 EF460-500
1SAX821001R1101 EF750-800
1SAZ401110R0001 DB200
1SAZ401901R1001 LT200/A
1SAZ421201R1001 TA200DU-90
1SAZ421201R1002 TA200DU-110
1SAZ421201R1003 TA200DU-135
1SAZ421201R1004 TA200DU-150
1SAZ421201R1005 TA200DU-175
1SAZ421201R1006 TA200DU-200
1SAZ431201R1001 TF140DU-90
1SAZ431201R1002 TF140DU-110
1SAZ431201R1003 TF140DU-135
1SAZ431201R1004 TF140DU-142
1SAZ701901R0001 DB16
1SAZ701902R0001 DB42
1SAZ701903R1001 WRH-F
1SAZ701903R1011 WRB-400
1SAZ701903R1012 WRB-600
1SAZ701903R1013 WRB-1000
1SAZ701903R1030 WRBG
1SAZ711201R1005 T16-0.13
1SAZ711201R1008 T16-0.17
1SAZ711201R1009 T16-0.23
1SAZ711201R1013 T16-0.31
1SAZ711201R1014 T16-0.41
1SAZ711201R1017 T16-0.55
1SAZ711201R1021 T16-0.74
1SAZ711201R1023 T16-1.0
1SAZ711201R1025 T16-1.3
1SAZ711201R1028 T16-1.7
1SAZ711201R1031 T16-2.3
Page
2/35
2/23
2/23
2/23
2/27
2/27
2/27
2/35
2/35
2/23
2/23
2/23
2/23
2/27
2/27
2/27
2/27
2/23
2/23
2/23
2/23
2/23
2/23
2/23
2/27
2/27
2/27
2/27
2/27
2/27
2/27
7/32
7/33
7/28
7/28
7/28
7/28
7/28
7/33
7/33
7/33
7/33
7/33
7/32
7/28
7/28
7/33
7/33
7/32
7/32
7/28
7/28
7/37
7/37
7/37
7/37
7/41
7/41
7/45
7/45
7/24
7/24
7/24
7/24
7/24
7/24
7/24
7/24
7/20
7/20
7/20
7/20
7/4
7/8
7/51
7/51
7/51
7/51
7/51
7/4
7/4
7/4
7/4
7/4
7/4
7/4
7/4
7/4
7/4
7/4
Index
Order code
Index
Order code classification
Type
1SAZ711201R1033 T16-3.1
1SAZ711201R1035 T16-4.2
1SAZ711201R1038 T16-5.7
1SAZ711201R1040 T16-7.6
1SAZ711201R1043 T16-10
1SAZ711201R1045 T16-13
1SAZ711201R1047 T16-16
1SAZ721201R1005 TF42-0.13
1SAZ721201R1008 TF42-0.17
1SAZ721201R1009 TF42-0.23
1SAZ721201R1013 TF42-0.31
1SAZ721201R1014 TF42-0.41
1SAZ721201R1017 TF42-0.55
1SAZ721201R1021 TF42-0.74
1SAZ721201R1023 TF42-1.0
1SAZ721201R1025 TF42-1.3
1SAZ721201R1028 TF42-1.7
1SAZ721201R1031 TF42-2.3
1SAZ721201R1033 TF42-3.1
1SAZ721201R1035 TF42-4.2
1SAZ721201R1038 TF42-5.7
1SAZ721201R1040 TF42-7.6
1SAZ721201R1043 TF42-10
1SAZ721201R1045 TF42-13
1SAZ721201R1047 TF42-16
1SAZ721201R1049 TF42-20
1SAZ721201R1051 TF42-24
1SAZ721201R1052 TF42-29
1SAZ721201R1053 TF42-35
1SAZ721201R1055 TF42-38
1SAZ811201R1001 TF65-28
1SAZ811201R1002 TF65-33
1SAZ811201R1003 TF65-40
1SAZ811201R1004 TF65-47
1SAZ811201R1005 TF65-53
1SAZ811201R1006 TF65-60
1SAZ811201R1007 TF65-67
1SAZ911201R1001 TF96-51
1SAZ911201R1002 TF96-60
1SAZ911201R1003 TF96-68
1SAZ911201R1004 TF96-78
1SAZ911201R1005 TF96-87
1SAZ911201R1006 TF96-96
1SBH101001R1622 NS22E-16
1SBH101001R1631 NS31E-16
1SBH101001R1640 NS40E-16
1SBH101001R1644 NS44E-16
1SBH101001R1653 NS53E-16
1SBH101001R1662 NS62E-16
1SBH101001R1671 NS71E-16
1SBH101001R1680 NS80E-16
1SBH101001R2022 NS22E-20
1SBH101001R2031 NS31E-20
1SBH101001R2040 NS40E-20
1SBH101001R2044 NS44E-20
1SBH101001R2053 NS53E-20
1SBH101001R2062 NS62E-20
1SBH101001R2071 NS71E-20
1SBH101001R2080 NS80E-20
1SBH101001R2622 NS22E-26
1SBH101001R2631 NS31E-26
1SBH101001R2640 NS40E-26
1SBH101001R2644 NS44E-26
1SBH101001R2653 NS53E-26
1SBH101001R2662 NS62E-26
1SBH101001R2671 NS71E-26
1SBH101001R2680 NS80E-26
1SBH101001R2822 NS22E-28
1SBH101001R2831 NS31E-28
1SBH101001R2840 NS40E-28
1SBH101001R2844 NS44E-28
1SBH101001R2853 NS53E-28
1SBH101001R2862 NS62E-28
1SBH101001R2871 NS71E-28
1SBH101001R2880 NS80E-28
1SBH101004R1622 NS22ES-16
1SBH101004R1631 NS31ES-16
1SBH101004R1640 NS40ES-16
1SBH101004R1644 NS44ES-16
1SBH101004R1653 NS53ES-16
1SBH101004R1662 NS62ES-16
1SBH101004R1671 NS71ES-16
1SBH101004R1680 NS80ES-16
1SBH101004R2022 NS22ES-20
1SBH101004R2031 NS31ES-20
1SBH101004R2040 NS40ES-20
1SBH101004R2044 NS44ES-20
1SBH101004R2053 NS53ES-20
1SBH101004R2062 NS62ES-20
1SBH101004R2071 NS71ES-20
Page
Order code
7/4
7/4
7/4
7/4
7/4
7/4
7/4
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/16
7/16
7/16
7/16
7/16
7/16
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
4/62
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
1SBH101004R2080 NS80ES-20
1SBH101004R2622 NS22ES-26
1SBH101004R2631 NS31ES-26
1SBH101004R2640 NS40ES-26
1SBH101004R2644 NS44ES-26
1SBH101004R2653 NS53ES-26
1SBH101004R2662 NS62ES-26
1SBH101004R2671 NS71ES-26
1SBH101004R2680 NS80ES-26
1SBH101004R2822 NS22ES-28
1SBH101004R2831 NS31ES-28
1SBH101004R2840 NS40ES-28
1SBH101004R2844 NS44ES-28
1SBH101004R2853 NS53ES-28
1SBH101004R2862 NS62ES-28
1SBH101004R2871 NS71ES-28
1SBH101004R2880 NS80ES-28
1SBH103001R8122 NSL22E-81
1SBH103001R8131 NSL31E-81
1SBH103001R8140 NSL40E-81
1SBH103001R8144 NSL44E-81
1SBH103001R8153 NSL53E-81
1SBH103001R8162 NSL62E-81
1SBH103001R8171 NSL71E-81
1SBH103001R8180 NSL80E-81
1SBH103001R8322 NSL22E-83
1SBH103001R8331 NSL31E-83
1SBH103001R8340 NSL40E-83
1SBH103001R8344 NSL44E-83
1SBH103001R8353 NSL53E-83
1SBH103001R8362 NSL62E-83
1SBH103001R8371 NSL71E-83
1SBH103001R8380 NSL80E-83
1SBH103001R8622 NSL22E-86
1SBH103001R8631 NSL31E-86
1SBH103001R8640 NSL40E-86
1SBH103001R8644 NSL44E-86
1SBH103001R8653 NSL53E-86
1SBH103001R8662 NSL62E-86
1SBH103001R8671 NSL71E-86
1SBH103001R8680 NSL80E-86
1SBH103001R8822 NSL22E-88
1SBH103001R8831 NSL31E-88
1SBH103001R8840 NSL40E-88
1SBH103001R8844 NSL44E-88
1SBH103001R8853 NSL53E-88
1SBH103001R8862 NSL62E-88
1SBH103001R8871 NSL71E-88
1SBH103001R8880 NSL80E-88
1SBH103004R8122 NSL22ES-81
1SBH103004R8131 NSL31ES-81
1SBH103004R8140 NSL40ES-81
1SBH103004R8144 NSL44ES-81
1SBH103004R8153 NSL53ES-81
1SBH103004R8162 NSL62ES-81
1SBH103004R8171 NSL71ES-81
1SBH103004R8180 NSL80ES-81
1SBH103004R8322 NSL22ES-83
1SBH103004R8331 NSL31ES-83
1SBH103004R8340 NSL40ES-83
1SBH103004R8344 NSL44ES-83
1SBH103004R8353 NSL53ES-83
1SBH103004R8362 NSL62ES-83
1SBH103004R8371 NSL71ES-83
1SBH103004R8380 NSL80ES-83
1SBH103004R8622 NSL22ES-86
1SBH103004R8631 NSL31ES-86
1SBH103004R8640 NSL40ES-86
1SBH103004R8644 NSL44ES-86
1SBH103004R8653 NSL53ES-86
1SBH103004R8662 NSL62ES-86
1SBH103004R8671 NSL71ES-86
1SBH103004R8680 NSL80ES-86
1SBH103004R8822 NSL22ES-88
1SBH103004R8831 NSL31ES-88
1SBH103004R8840 NSL40ES-88
1SBH103004R8844 NSL44ES-88
1SBH103004R8853 NSL53ES-88
1SBH103004R8862 NSL62ES-88
1SBH103004R8871 NSL71ES-88
1SBH103004R8880 NSL80ES-88
1SBH136001R2022 NFZ22E-20
1SBH136001R2031 NFZ31E-20
1SBH136001R2039 NFZ33/11-20
1SBH136001R2040 NFZ40E-20
1SBH136001R2044 NFZ44E-20
1SBH136001R2053 NFZ53E-20
1SBH136001R2059 NFZ51/11-20
1SBH136001R2062 NFZ62E-20
1SBH136001R2071 NFZ71E-20
Type
Page
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
6/22
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
4/63
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
6/23
5/305
5/305
5/309
5/305
5/309
5/309
5/309
5/309
5/309
Order code
Type
Page
1SBH136001R2080 NFZ80E-20
1SBH136001R2122 NFZ22E-21
1SBH136001R2131 NFZ31E-21
1SBH136001R2139 NFZ33/11-21
1SBH136001R2140 NFZ40E-21
1SBH136001R2144 NFZ44E-21
1SBH136001R2153 NFZ53E-21
1SBH136001R2159 NFZ51/11-21
1SBH136001R2162 NFZ62E-21
1SBH136001R2171 NFZ71E-21
1SBH136001R2180 NFZ80E-21
1SBH136001R2222 NFZ22E-22
1SBH136001R2231 NFZ31E-22
1SBH136001R2239 NFZ33/11-22
1SBH136001R2240 NFZ40E-22
1SBH136001R2244 NFZ44E-22
1SBH136001R2253 NFZ53E-22
1SBH136001R2259 NFZ51/11-22
1SBH136001R2262 NFZ62E-22
1SBH136001R2271 NFZ71E-22
1SBH136001R2280 NFZ80E-22
1SBH136001R2322 NFZ22E-23
1SBH136001R2331 NFZ31E-23
1SBH136001R2339 NFZ33/11-23
1SBH136001R2340 NFZ40E-23
1SBH136001R2344 NFZ44E-23
1SBH136001R2353 NFZ53E-23
1SBH136001R2359 NFZ51/11-23
1SBH136001R2362 NFZ62E-23
1SBH136001R2371 NFZ71E-23
1SBH136001R2380 NFZ80E-23
1SBH136004R2022 NFZ22ES-20
1SBH136004R2031 NFZ31ES-20
1SBH136004R2040 NFZ40ES-20
1SBH136004R2044 NFZ44ES-20
1SBH136004R2053 NFZ53ES-20
1SBH136004R2062 NFZ62ES-20
1SBH136004R2071 NFZ71ES-20
1SBH136004R2080 NFZ80ES-20
1SBH136004R2122 NFZ22ES-21
1SBH136004R2131 NFZ31ES-21
1SBH136004R2140 NFZ40ES-21
1SBH136004R2144 NFZ44ES-21
1SBH136004R2153 NFZ53ES-21
1SBH136004R2162 NFZ62ES-21
1SBH136004R2171 NFZ71ES-21
1SBH136004R2180 NFZ80ES-21
1SBH136004R2222 NFZ22ES-22
1SBH136004R2231 NFZ31ES-22
1SBH136004R2240 NFZ40ES-22
1SBH136004R2244 NFZ44ES-22
1SBH136004R2253 NFZ53ES-22
1SBH136004R2262 NFZ62ES-22
1SBH136004R2271 NFZ71ES-22
1SBH136004R2280 NFZ80ES-22
1SBH136004R2322 NFZ22ES-23
1SBH136004R2331 NFZ31ES-23
1SBH136004R2340 NFZ40ES-23
1SBH136004R2344 NFZ44ES-23
1SBH136004R2353 NFZ53ES-23
1SBH136004R2362 NFZ62ES-23
1SBH136004R2371 NFZ71ES-23
1SBH136004R2380 NFZ80ES-23
1SBH137001R1222 NF22E-12
1SBH137001R1231 NF31E-12
1SBH137001R1239 NF33/11-12
1SBH137001R1240 NF40E-12
1SBH137001R1244 NF44E-12
1SBH137001R1253 NF53E-12
1SBH137001R1259 NF51/11-12
1SBH137001R1262 NF62E-12
1SBH137001R1271 NF71E-12
1SBH137001R1280 NF80E-12
1SBH137001R1322 NF22E-13
1SBH137001R1331 NF31E-13
1SBH137001R1339 NF33/11-13
1SBH137001R1340 NF40E-13
1SBH137001R1344 NF44E-13
1SBH137001R1353 NF53E-13
1SBH137001R1359 NF51/11-13
1SBH137001R1362 NF62E-13
1SBH137001R1371 NF71E-13
1SBH137001R1380 NF80E-13
1SBH137001R1422 NF22E-14
1SBH137001R1431 NF31E-14
1SBH137001R1439 NF33/11-14
1SBH137001R1440 NF40E-14
1SBH137001R1444 NF44E-14
1SBH137001R1453 NF53E-14
1SBH137001R1459 NF51/11-14
5/309
5/305
5/305
5/309
5/305
5/309
5/309
5/309
5/309
5/309
5/309
5/305
5/305
5/309
5/305
5/309
5/309
5/309
5/309
5/309
5/309
5/305
5/305
5/309
5/305
5/309
5/309
5/309
5/309
5/309
5/309
6/69
6/69
6/69
6/71
6/71
6/71
6/71
6/71
6/69
6/69
6/69
6/71
6/71
6/71
6/71
6/71
6/69
6/69
6/69
6/71
6/71
6/71
6/71
6/71
6/69
6/69
6/69
6/71
6/71
6/71
6/71
6/71
5/304
5/304
5/308
5/304
5/308
5/308
5/308
5/308
5/308
5/308
5/304
5/304
5/308
5/304
5/308
5/308
5/308
5/308
5/308
5/308
5/304
5/304
5/308
5/304
5/308
5/308
5/308
ABB | 13/1
13
Index
Order code
Index
Order code classification
13
Type
1SBH137001R1462 NF62E-14
1SBH137001R1471 NF71E-14
1SBH137001R1480 NF80E-14
1SBH137001R4122 NF22E-41
1SBH137001R4131 NF31E-41
1SBH137001R4139 NF33/11-41
1SBH137001R4140 NF40E-41
1SBH137001R4144 NF44E-41
1SBH137001R4153 NF53E-41
1SBH137001R4159 NF51/11-41
1SBH137001R4162 NF62E-41
1SBH137001R4171 NF71E-41
1SBH137001R4180 NF80E-41
1SBH137004R1222 NF22ES-12
1SBH137004R1231 NF31ES-12
1SBH137004R1240 NF40ES-12
1SBH137004R1244 NF44ES-12
1SBH137004R1253 NF53ES-12
1SBH137004R1262 NF62ES-12
1SBH137004R1271 NF71ES-12
1SBH137004R1280 NF80ES-12
1SBH137004R1322 NF22ES-13
1SBH137004R1331 NF31ES-13
1SBH137004R1340 NF40ES-13
1SBH137004R1344 NF44ES-13
1SBH137004R1353 NF53ES-13
1SBH137004R1362 NF62ES-13
1SBH137004R1371 NF71ES-13
1SBH137004R1380 NF80ES-13
1SBH137004R1422 NF22ES-14
1SBH137004R1431 NF31ES-14
1SBH137004R1440 NF40ES-14
1SBH137004R1444 NF44ES-14
1SBH137004R1453 NF53ES-14
1SBH137004R1462 NF62ES-14
1SBH137004R1471 NF71ES-14
1SBH137004R1480 NF80ES-14
1SBH137004R4122 NF22ES-41
1SBH137004R4131 NF31ES-41
1SBH137004R4140 NF40ES-41
1SBH137004R4144 NF44ES-41
1SBH137004R4153 NF53ES-41
1SBH137004R4162 NF62ES-41
1SBH137004R4171 NF71ES-41
1SBH137004R4180 NF80ES-41
1SBK103600M1600 VAS09EM-16M
1SBK103600M2000 VAS09EM-20M
1SBK103600M2600 VAS09EM-26M
1SBK103600M2800 VAS09EM-28M
1SBK103700M8100 VASL09EM-81M
1SBK103700M8300 VASL09EM-83M
1SBK103700M8600 VASL09EM-86M
1SBK103700M8800 VASL09EM-88M
1SBK103800M1600 VAS09SEM-16M
1SBK103800M2000 VAS09SEM-20M
1SBK103800M2600 VAS09SEM-26M
1SBK103800M2800 VAS09SEM-28M
1SBK103900M8100 VASL09SEM-81M
1SBK103900M8300 VASL09SEM-83M
1SBK103900M8600 VASL09SEM-86M
1SBK103900M8800 VASL09SEM-88M
1SBK104035R2800 DRAS09-28P
1SBK104035R2900 DRAS09-29P
1SBK104135R2600 DRAS09-26N
1SBK104135R2700 DRAS09-27N
1SBK104235R2000 DRAS09-20S
1SBK104335R8100 DRASL09-81S
1SBK104335R8300 DRASL09-83S
1SBK113600M1600 VAS12EM-16M
1SBK113600M2000 VAS12EM-20M
1SBK113600M2600 VAS12EM-26M
1SBK113600M2800 VAS12EM-28M
1SBK113700M8100 VASL12EM-81M
1SBK113700M8300 VASL12EM-83M
1SBK113700M8600 VASL12EM-86M
1SBK113700M8800 VASL12EM-88M
1SBK113800M1600 VAS12SEM-16M
1SBK113800M2000 VAS12SEM-20M
1SBK113800M2600 VAS12SEM-26M
1SBK113800M2800 VAS12SEM-28M
1SBK113900M8100 VASL12SEM-81M
1SBK113900M8300 VASL12SEM-83M
1SBK113900M8600 VASL12SEM-86M
1SBK113900M8800 VASL12SEM-88M
1SBK114035R2800 DRAS12-28P
1SBK114035R2900 DRAS12-29P
1SBK114135R2600 DRAS12-26N
1SBK114135R2700 DRAS12-27N
1SBK114235R2000 DRAS12-20S
1SBK114335R8100 DRASL12-81S
13/2 | ABB
Page
5/308
5/308
5/308
5/304
5/304
5/308
5/304
5/308
5/308
5/308
5/308
5/308
5/308
6/68
6/68
6/68
6/70
6/70
6/70
6/70
6/70
6/68
6/68
6/68
6/70
6/70
6/70
6/70
6/70
6/68
6/68
6/68
6/70
6/70
6/70
6/70
6/70
6/68
6/68
6/68
6/70
6/70
6/70
6/70
6/70
4/46
4/46
4/46
4/46
4/47
4/47
4/47
4/47
4/46
4/46
4/46
4/46
4/47
4/47
4/47
4/47
8/2
8/2
8/2
8/2
8/2
8/2
8/2
4/46
4/46
4/46
4/46
4/47
4/47
4/47
4/47
4/46
4/46
4/46
4/46
4/47
4/47
4/47
4/47
8/2
8/2
8/2
8/2
8/2
8/2
Order code
Type
1SBK114335R8300 DRASL12-83S
1SBK123600M1600 VAS16EM-16M
1SBK123600M2000 VAS16EM-20M
1SBK123600M2600 VAS16EM-26M
1SBK123600M2800 VAS16EM-28M
1SBK123700M8100 VASL16EM-81M
1SBK123700M8300 VASL16EM-83M
1SBK123700M8600 VASL16EM-86M
1SBK123700M8800 VASL16EM-88M
1SBK123800M1600 VAS16SEM-16M
1SBK123800M2000 VAS16SEM-20M
1SBK123800M2600 VAS16SEM-26M
1SBK123800M2800 VAS16SEM-28M
1SBK123900M8100 VASL16SEM-81M
1SBK123900M8300 VASL16SEM-83M
1SBK123900M8600 VASL16SEM-86M
1SBK123900M8800 VASL16SEM-88M
1SBK124035R2800 DRAS16-28P
1SBK124035R2900 DRAS16-29P
1SBK124135R2600 DRAS16-26N
1SBK124135R2700 DRAS16-27N
1SBK124235R2000 DRAS16-20S
1SBK124335R8100 DRASL16-81S
1SBK124335R8300 DRASL16-83S
1SBL101001R1601 AS09-30-01-16
1SBL101001R1610 AS09-30-10-16
1SBL101001R1632 AS09-30-32-16
1SBL101001R2001 AS09-30-01-20
1SBL101001R2010 AS09-30-10-20
1SBL101001R2032 AS09-30-32-20
1SBL101001R2601 AS09-30-01-26
1SBL101001R2610 AS09-30-10-26
1SBL101001R2632 AS09-30-32-26
1SBL101001R2801 AS09-30-01-28
1SBL101001R2810 AS09-30-10-28
1SBL101001R2832 AS09-30-32-28
1SBL101004R1601 AS09-30-01S-16
1SBL101004R1610 AS09-30-10S-16
1SBL101004R1632 AS09-30-32S-16
1SBL101004R2001 AS09-30-01S-20
1SBL101004R2010 AS09-30-10S-20
1SBL101004R2032 AS09-30-32S-20
1SBL101004R2601 AS09-30-01S-26
1SBL101004R2610 AS09-30-10S-26
1SBL101004R2632 AS09-30-32S-26
1SBL101004R2801 AS09-30-01S-28
1SBL101004R2810 AS09-30-10S-28
1SBL101004R2832 AS09-30-32S-28
1SBL103001R8101 ASL09-30-01-81
1SBL103001R8110 ASL09-30-10-81
1SBL103001R8132 ASL09-30-32-81
1SBL103001R8301 ASL09-30-01-83
1SBL103001R8310 ASL09-30-10-83
1SBL103001R8332 ASL09-30-32-83
1SBL103001R8601 ASL09-30-01-86
1SBL103001R8610 ASL09-30-10-86
1SBL103001R8632 ASL09-30-32-86
1SBL103001R8801 ASL09-30-01-88
1SBL103001R8810 ASL09-30-10-88
1SBL103001R8832 ASL09-30-32-88
1SBL103004R8101 ASL09-30-01S-81
1SBL103004R8110 ASL09-30-10S-81
1SBL103004R8132 ASL09-30-32S-81
1SBL103004R8301 ASL09-30-01S-83
1SBL103004R8310 ASL09-30-10S-83
1SBL103004R8332 ASL09-30-32S-83
1SBL103004R8601 ASL09-30-01S-86
1SBL103004R8610 ASL09-30-10S-86
1SBL103004R8632 ASL09-30-32S-86
1SBL103004R8801 ASL09-30-01S-88
1SBL103004R8810 ASL09-30-10S-88
1SBL103004R8832 ASL09-30-32S-88
1SBL111001R1601 AS12-30-01-16
1SBL111001R1610 AS12-30-10-16
1SBL111001R1632 AS12-30-32-16
1SBL111001R2001 AS12-30-01-20
1SBL111001R2010 AS12-30-10-20
1SBL111001R2032 AS12-30-32-20
1SBL111001R2601 AS12-30-01-26
1SBL111001R2610 AS12-30-10-26
1SBL111001R2632 AS12-30-32-26
1SBL111001R2801 AS12-30-01-28
1SBL111001R2810 AS12-30-10-28
1SBL111001R2832 AS12-30-32-28
1SBL111004R1601 AS12-30-01S-16
1SBL111004R1610 AS12-30-10S-16
1SBL111004R1632 AS12-30-32S-16
1SBL111004R2001 AS12-30-01S-20
1SBL111004R2010 AS12-30-10S-20
1SBL111004R2032 AS12-30-32S-20
Page
Order code
8/2
4/46
4/46
4/46
4/46
4/47
4/47
4/47
4/47
4/46
4/46
4/46
4/46
4/47
4/47
4/47
4/47
8/2
8/2
8/2
8/2
8/2
8/2
8/2
4/32
4/32
4/34
4/32
4/32
4/34
4/32
4/32
4/34
4/32
4/32
4/34
6/4
6/4
6/6
6/4
6/4
6/6
6/4
6/4
6/6
6/4
6/4
6/6
4/33
4/33
4/35
4/33
4/33
4/35
4/33
4/33
4/35
4/33
4/33
4/35
6/5
6/5
6/7
6/5
6/5
6/7
6/5
6/5
6/7
6/5
6/5
6/7
4/32
4/32
4/34
4/32
4/32
4/34
4/32
4/32
4/34
4/32
4/32
4/34
6/4
6/4
6/6
6/4
6/4
6/6
1SBL111004R2601 AS12-30-01S-26
6/4
1SBL111004R2610 AS12-30-10S-26
6/4
1SBL111004R2632 AS12-30-32S-26
6/6
1SBL111004R2801 AS12-30-01S-28
6/4
1SBL111004R2810 AS12-30-10S-28
6/4
1SBL111004R2832 AS12-30-32S-28
6/6
1SBL113001R8101 ASL12-30-01-81 4/33
1SBL113001R8110 ASL12-30-10-81 4/33
1SBL113001R8132 ASL12-30-32-81 4/35
1SBL113001R8301 ASL12-30-01-83 4/33
1SBL113001R8310 ASL12-30-10-83 4/33
1SBL113001R8332 ASL12-30-32-83 4/35
1SBL113001R8601 ASL12-30-01-86 4/33
1SBL113001R8610 ASL12-30-10-86 4/33
1SBL113001R8632 ASL12-30-32-86 4/35
1SBL113001R8801 ASL12-30-01-88 4/33
1SBL113001R8810 ASL12-30-10-88 4/33
1SBL113001R8832 ASL12-30-32-88 4/35
1SBL113004R8101 ASL12-30-01S-81 6/5
1SBL113004R8110 ASL12-30-10S-81 6/5
1SBL113004R8132 ASL12-30-32S-81 6/7
1SBL113004R8301 ASL12-30-01S-83 6/5
1SBL113004R8310 ASL12-30-10S-83 6/5
1SBL113004R8332 ASL12-30-32S-83 6/7
1SBL113004R8601 ASL12-30-01S-86 6/5
1SBL113004R8610 ASL12-30-10S-86 6/5
1SBL113004R8632 ASL12-30-32S-86 6/7
1SBL113004R8801 ASL12-30-01S-88 6/5
1SBL113004R8810 ASL12-30-10S-88 6/5
1SBL113004R8832 ASL12-30-32S-88 6/7
1SBL121001R1601 AS16-30-01-16
4/32
1SBL121001R1610 AS16-30-10-16
4/32
1SBL121001R1632 AS16-30-32-16
4/34
1SBL121001R2001 AS16-30-01-20
4/32
1SBL121001R2010 AS16-30-10-20
4/32
1SBL121001R2032 AS16-30-32-20
4/34
1SBL121001R2601 AS16-30-01-26
4/32
1SBL121001R2610 AS16-30-10-26
4/32
1SBL121001R2632 AS16-30-32-26
4/34
1SBL121001R2801 AS16-30-01-28
4/32
1SBL121001R2810 AS16-30-10-28
4/32
1SBL121001R2832 AS16-30-32-28
4/34
1SBL121004R1601 AS16-30-01S-16
6/4
1SBL121004R1610 AS16-30-10S-16
6/4
1SBL121004R1632 AS16-30-32S-16
6/6
1SBL121004R2001 AS16-30-01S-20
6/4
1SBL121004R2010 AS16-30-10S-20
6/4
1SBL121004R2032 AS16-30-32S-20
6/6
1SBL121004R2601 AS16-30-01S-26
6/4
1SBL121004R2610 AS16-30-10S-26
6/4
1SBL121004R2632 AS16-30-32S-26
6/6
1SBL121004R2801 AS16-30-01S-28
6/4
1SBL121004R2810 AS16-30-10S-28
6/4
1SBL121004R2832 AS16-30-32S-28
6/6
1SBL123001R8101 ASL16-30-01-81 4/33
1SBL123001R8110 ASL16-30-10-81 4/33
1SBL123001R8132 ASL16-30-32-81 4/35
1SBL123001R8301 ASL16-30-01-83 4/33
1SBL123001R8310 ASL16-30-10-83 4/33
1SBL123001R8332 ASL16-30-32-83 4/35
1SBL123001R8601 ASL16-30-01-86 4/33
1SBL123001R8610 ASL16-30-10-86 4/33
1SBL123001R8632 ASL16-30-32-86 4/35
1SBL123001R8801 ASL16-30-01-88 4/33
1SBL123001R8810 ASL16-30-10-88 4/33
1SBL123001R8832 ASL16-30-32-88 4/35
1SBL123004R8101 ASL16-30-01S-81 6/5
1SBL123004R8110 ASL16-30-10S-81 6/5
1SBL123004R8132 ASL16-30-32S-81 6/7
1SBL123004R8301 ASL16-30-01S-83 6/5
1SBL123004R8310 ASL16-30-10S-83 6/5
1SBL123004R8332 ASL16-30-32S-83 6/7
1SBL123004R8601 ASL16-30-01S-86 6/5
1SBL123004R8610 ASL16-30-10S-86 6/5
1SBL123004R8632 ASL16-30-32S-86 6/7
1SBL123004R8801 ASL16-30-01S-88 6/5
1SBL123004R8810 ASL16-30-10S-88 6/5
1SBL123004R8832 ASL16-30-32S-88 6/7
1SBL136001R2022 AF09Z-30-22-20 5/105
1SBL136001R2122 AF09Z-30-22-21 5/105
1SBL136001R2222 AF09Z-30-22-22 5/105
1SBL136001R2322 AF09Z-30-22-23 5/105
1SBL136004R2001 AF09Z-30-01S-20 6/47
1SBL136004R2010 AF09Z-30-10S-20 6/47
1SBL136004R2022 AF09Z-30-22S-20 6/49
1SBL136004R2101 AF09Z-30-01S-21 6/47
1SBL136004R2110 AF09Z-30-10S-21 6/47
1SBL136004R2122 AF09Z-30-22S-21 6/49
1SBL136004R2201 AF09Z-30-01S-22 6/47
1SBL136004R2210 AF09Z-30-10S-22 6/47
Type
Page
Index
Order code
Index
Order code classification
Type
Page
1SBL136004R2222 AF09Z-30-22S-22 6/49
1SBL136004R2301 AF09Z-30-01S-23 6/47
1SBL136004R2310 AF09Z-30-10S-23 6/47
1SBL136004R2322 AF09Z-30-22S-23 6/49
1SBL136201R2000 AF09Z-40-00-20 5/183
1SBL136201R2100 AF09Z-40-00-21 5/183
1SBL136201R2200 AF09Z-40-00-22 5/183
1SBL136201R2300 AF09Z-40-00-23 5/183
1SBL136501R2000 AF09Z-22-00-20 5/183
1SBL136501R2100 AF09Z-22-00-21 5/183
1SBL136501R2200 AF09Z-22-00-22 5/183
1SBL136501R2300 AF09Z-22-00-23 5/183
1SBL137001R1201 AF09-30-01-12
5/82
1SBL137001R1210 AF09-30-10-12
5/82
1SBL137001R1222 AF09-30-22-12 5/104
1SBL137001R1301 AF09-30-01-13
5/82
1SBL137001R1310 AF09-30-10-13
5/82
1SBL137001R1322 AF09-30-22-13 5/104
1SBL137001R1401 AF09-30-01-14
5/82
1SBL137001R1410 AF09-30-10-14
5/82
1SBL137001R1422 AF09-30-22-14 5/104
1SBL137001R4101 AF09-30-01-41
5/82
1SBL137001R4110 AF09-30-10-41
5/82
1SBL137001R4122 AF09-30-22-41 5/104
1SBL137004R1201 AF09-30-01S-12 6/46
1SBL137004R1210 AF09-30-10S-12 6/46
1SBL137004R1222 AF09-30-22S-12 6/48
1SBL137004R1301 AF09-30-01S-13 6/46
1SBL137004R1310 AF09-30-10S-13 6/46
1SBL137004R1322 AF09-30-22S-13 6/48
1SBL137004R1401 AF09-30-01S-14 6/46
1SBL137004R1410 AF09-30-10S-14 6/46
1SBL137004R1422 AF09-30-22S-14 6/48
1SBL137004R4101 AF09-30-01S-41 6/46
1SBL137004R4110 AF09-30-10S-41 6/46
1SBL137004R4122 AF09-30-22S-41 6/48
1SBL137201R1200 AF09-40-00-12 5/182
1SBL137201R1300 AF09-40-00-13 5/182
1SBL137201R1400 AF09-40-00-14 5/182
1SBL137201R4100 AF09-40-00-41 5/182
1SBL137501R1200 AF09-22-00-12 5/182
1SBL137501R1300 AF09-22-00-13 5/182
1SBL137501R1400 AF09-22-00-14 5/182
1SBL137501R4100 AF09-22-00-41 5/182
1SBL156001R2022 AF12Z-30-22-20 5/105
1SBL156001R2122 AF12Z-30-22-21 5/105
1SBL156001R2222 AF12Z-30-22-22 5/105
1SBL156001R2322 AF12Z-30-22-23 5/105
1SBL156004R2001 AF12Z-30-01S-20 6/47
1SBL156004R2010 AF12Z-30-10S-20 6/47
1SBL156004R2022 AF12Z-30-22S-20 6/49
1SBL156004R2101 AF12Z-30-01S-21 6/47
1SBL156004R2110 AF12Z-30-10S-21 6/47
1SBL156004R2122 AF12Z-30-22S-21 6/49
1SBL156004R2201 AF12Z-30-01S-22 6/47
1SBL156004R2210 AF12Z-30-10S-22 6/47
1SBL156004R2222 AF12Z-30-22S-22 6/49
1SBL156004R2301 AF12Z-30-01S-23 6/47
1SBL156004R2310 AF12Z-30-10S-23 6/47
1SBL156004R2322 AF12Z-30-22S-23 6/49
1SBL157001R1201 AF12-30-01-12
5/82
1SBL157001R1210 AF12-30-10-12
5/82
1SBL157001R1222 AF12-30-22-12 5/104
1SBL157001R1301 AF12-30-01-13
5/82
1SBL157001R1310 AF12-30-10-13
5/82
1SBL157001R1322 AF12-30-22-13 5/104
1SBL157001R1401 AF12-30-01-14
5/82
1SBL157001R1410 AF12-30-10-14
5/82
1SBL157001R1422 AF12-30-22-14 5/104
1SBL157001R4101 AF12-30-01-41
5/82
1SBL157001R4110 AF12-30-10-41
5/82
1SBL157001R4122 AF12-30-22-41 5/104
1SBL157004R1201 AF12-30-01S-12 6/46
1SBL157004R1210 AF12-30-10S-12 6/46
1SBL157004R1222 AF12-30-22S-12 6/48
1SBL157004R1301 AF12-30-01S-13 6/46
1SBL157004R1310 AF12-30-10S-13 6/46
1SBL157004R1322 AF12-30-22S-13 6/48
1SBL157004R1401 AF12-30-01S-14 6/46
1SBL157004R1410 AF12-30-10S-14 6/46
1SBL157004R1422 AF12-30-22S-14 6/48
1SBL157004R4101 AF12-30-01S-41 6/46
1SBL157004R4110 AF12-30-10S-41 6/46
1SBL157004R4122 AF12-30-22S-41 6/48
1SBL176001R2022 AF16Z-30-22-20 5/105
1SBL176001R2122 AF16Z-30-22-21 5/105
1SBL176001R2222 AF16Z-30-22-22 5/105
1SBL176001R2322 AF16Z-30-22-23 5/105
1SBL176004R2001 AF16Z-30-01S-20 6/47
1SBL176004R2010 AF16Z-30-10S-20 6/47
Order code
Type
Page
1SBL176004R2022 AF16Z-30-22S-20 6/49
1SBL176004R2101 AF16Z-30-01S-21 6/47
1SBL176004R2110 AF16Z-30-10S-21 6/47
1SBL176004R2122 AF16Z-30-22S-21 6/49
1SBL176004R2201 AF16Z-30-01S-22 6/47
1SBL176004R2210 AF16Z-30-10S-22 6/47
1SBL176004R2222 AF16Z-30-22S-22 6/49
1SBL176004R2301 AF16Z-30-01S-23 6/47
1SBL176004R2310 AF16Z-30-10S-23 6/47
1SBL176004R2322 AF16Z-30-22S-23 6/49
1SBL176201R2000 AF16Z-40-00-20 5/183
1SBL176201R2100 AF16Z-40-00-21 5/183
1SBL176201R2200 AF16Z-40-00-22 5/183
1SBL176201R2300 AF16Z-40-00-23 5/183
1SBL176501R2000 AF16Z-22-00-20 5/183
1SBL176501R2100 AF16Z-22-00-21 5/183
1SBL176501R2200 AF16Z-22-00-22 5/183
1SBL176501R2300 AF16Z-22-00-23 5/183
1SBL177001R1201 AF16-30-01-12
5/82
1SBL177001R1210 AF16-30-10-12
5/82
1SBL177001R1222 AF16-30-22-12 5/104
1SBL177001R1301 AF16-30-01-13
5/82
1SBL177001R1310 AF16-30-10-13
5/82
1SBL177001R1322 AF16-30-22-13 5/104
1SBL177001R1401 AF16-30-01-14
5/82
1SBL177001R1410 AF16-30-10-14
5/82
1SBL177001R1422 AF16-30-22-14 5/104
1SBL177001R4101 AF16-30-01-41
5/82
1SBL177001R4110 AF16-30-10-41
5/82
1SBL177001R4122 AF16-30-22-41 5/104
1SBL177004R1201 AF16-30-01S-12 6/46
1SBL177004R1210 AF16-30-10S-12 6/46
1SBL177004R1222 AF16-30-22S-12 6/48
1SBL177004R1301 AF16-30-01S-13 6/46
1SBL177004R1310 AF16-30-10S-13 6/46
1SBL177004R1322 AF16-30-22S-13 6/48
1SBL177004R1401 AF16-30-01S-14 6/46
1SBL177004R1410 AF16-30-10S-14 6/46
1SBL177004R1422 AF16-30-22S-14 6/48
1SBL177004R4101 AF16-30-01S-41 6/46
1SBL177004R4110 AF16-30-10S-41 6/46
1SBL177004R4122 AF16-30-22S-41 6/48
1SBL177201R1200 AF16-40-00-12 5/182
1SBL177201R1300 AF16-40-00-13 5/182
1SBL177201R1400 AF16-40-00-14 5/182
1SBL177201R4100 AF16-40-00-41 5/182
1SBL177501R1200 AF16-22-00-12 5/182
1SBL177501R1300 AF16-22-00-13 5/182
1SBL177501R1400 AF16-22-00-14 5/182
1SBL177501R4100 AF16-22-00-41 5/182
1SBL181022R8010 UA16-30-10
5/276
1SBL181022R8110 UA16-30-10
5/276
1SBL181022R8310 UA16-30-10
5/276
1SBL181022R8410 UA16-30-10
5/276
1SBL181022R8510 UA16-30-10
5/276
1SBL181022R8610 UA16-30-10
5/276
1SBL181022R8810 UA16-30-10
5/276
1SBL181024R8010 UA16-30-10RA 5/266
1SBL181024R8110 UA16-30-10RA 5/266
1SBL181024R8310 UA16-30-10RA 5/266
1SBL181024R8410 UA16-30-10RA 5/266
1SBL181024R8510 UA16-30-10RA 5/266
1SBL181024R8610 UA16-30-10RA 5/266
1SBL181024R8810 UA16-30-10RA 5/266
1SBL236001R2011 AF26Z-30-11-20 5/105
1SBL236001R2022 AF26Z-30-22-20 5/105
1SBL236001R2111 AF26Z-30-11-21 5/105
1SBL236001R2122 AF26Z-30-22-21 5/105
1SBL236001R2211 AF26Z-30-11-22 5/105
1SBL236001R2222 AF26Z-30-22-22 5/105
1SBL236001R2311 AF26Z-30-11-23 5/105
1SBL236001R2322 AF26Z-30-22-23 5/105
1SBL236004R2000 AF26Z-30-00S-20 6/47
1SBL236004R2011 AF26Z-30-11S-20 6/49
1SBL236004R2022 AF26Z-30-22S-20 6/49
1SBL236004R2100 AF26Z-30-00S-21 6/47
1SBL236004R2111 AF26Z-30-11S-21 6/49
1SBL236004R2122 AF26Z-30-22S-21 6/49
1SBL236004R2200 AF26Z-30-00S-22 6/47
1SBL236004R2211 AF26Z-30-11S-22 6/49
1SBL236004R2222 AF26Z-30-22S-22 6/49
1SBL236004R2300 AF26Z-30-00S-23 6/47
1SBL236004R2311 AF26Z-30-11S-23 6/49
1SBL236004R2322 AF26Z-30-22S-23 6/49
1SBL236201R2000 AF26Z-40-00-20 5/183
1SBL236201R2100 AF26Z-40-00-21 5/183
1SBL236201R2200 AF26Z-40-00-22 5/183
1SBL236201R2300 AF26Z-40-00-23 5/183
1SBL236501R2000 AF26Z-22-00-20 5/183
1SBL236501R2100 AF26Z-22-00-21 5/183
Order code
Type
Page
1SBL236501R2200 AF26Z-22-00-22
1SBL236501R2300 AF26Z-22-00-23
1SBL237001R1200 AF26-30-00-12
1SBL237001R1211 AF26-30-11-12
1SBL237001R1222 AF26-30-22-12
1SBL237001R1300 AF26-30-00-13
1SBL237001R1311 AF26-30-11-13
1SBL237001R1322 AF26-30-22-13
1SBL237001R1400 AF26-30-00-14
1SBL237001R1411 AF26-30-11-14
1SBL237001R1422 AF26-30-22-14
1SBL237001R4100 AF26-30-00-41
1SBL237001R4111 AF26-30-11-41
1SBL237001R4122 AF26-30-22-41
1SBL237004R1200 AF26-30-00S-12
1SBL237004R1211 AF26-30-11S-12
1SBL237004R1222 AF26-30-22S-12
1SBL237004R1300 AF26-30-00S-13
1SBL237004R1311 AF26-30-11S-13
1SBL237004R1322 AF26-30-22S-13
1SBL237004R1400 AF26-30-00S-14
1SBL237004R1411 AF26-30-11S-14
1SBL237004R1422 AF26-30-22S-14
1SBL237004R4100 AF26-30-00S-41
1SBL237004R4111 AF26-30-11S-41
1SBL237004R4122 AF26-30-22S-41
1SBL237201R1200 AF26-40-00-12
1SBL237201R1300 AF26-40-00-13
1SBL237201R1400 AF26-40-00-14
1SBL237201R4100 AF26-40-00-41
1SBL237501R1200 AF26-22-00-12
1SBL237501R1300 AF26-22-00-13
1SBL237501R1400 AF26-22-00-14
1SBL237501R4100 AF26-22-00-41
1SBL241022R8010 UA26-30-10
1SBL241022R8110 UA26-30-10
1SBL241022R8310 UA26-30-10
1SBL241022R8410 UA26-30-10
1SBL241022R8510 UA26-30-10
1SBL241022R8610 UA26-30-10
1SBL241022R8810 UA26-30-10
1SBL241024R8010 UA26-30-10RA
1SBL241024R8110 UA26-30-10RA
1SBL241024R8310 UA26-30-10RA
1SBL241024R8410 UA26-30-10RA
1SBL241024R8510 UA26-30-10RA
1SBL241024R8610 UA26-30-10RA
1SBL241024R8810 UA26-30-10RA
1SBL276001R2011 AF30Z-30-11-20
1SBL276001R2022 AF30Z-30-22-20
1SBL276001R2111 AF30Z-30-11-21
1SBL276001R2122 AF30Z-30-22-21
1SBL276001R2211 AF30Z-30-11-22
1SBL276001R2222 AF30Z-30-22-22
1SBL276001R2311 AF30Z-30-11-23
1SBL276001R2322 AF30Z-30-22-23
1SBL277001R1200 AF30-30-00-12
1SBL277001R1211 AF30-30-11-12
1SBL277001R1222 AF30-30-22-12
1SBL277001R1300 AF30-30-00-13
1SBL277001R1311 AF30-30-11-13
1SBL277001R1322 AF30-30-22-13
1SBL277001R1400 AF30-30-00-14
1SBL277001R1411 AF30-30-11-14
1SBL277001R1422 AF30-30-22-14
1SBL277001R4100 AF30-30-00-41
1SBL277001R4111 AF30-30-11-41
1SBL277001R4122 AF30-30-22-41
1SBL281022R8010 UA30-30-10
1SBL281022R8110 UA30-30-10
1SBL281022R8310 UA30-30-10
1SBL281022R8410 UA30-30-10
1SBL281022R8510 UA30-30-10
1SBL281022R8610 UA30-30-10
1SBL281022R8810 UA30-30-10
1SBL281024R8010 UA30-30-10RA
1SBL281024R8110 UA30-30-10RA
1SBL281024R8310 UA30-30-10RA
1SBL281024R8410 UA30-30-10RA
1SBL281024R8510 UA30-30-10RA
1SBL281024R8610 UA30-30-10RA
1SBL281024R8810 UA30-30-10RA
1SBL296001R2011 AF38Z-30-11-20
1SBL296001R2022 AF38Z-30-22-20
1SBL296001R2111 AF38Z-30-11-21
1SBL296001R2122 AF38Z-30-22-21
1SBL296001R2211 AF38Z-30-11-22
1SBL296001R2222 AF38Z-30-22-22
1SBL296001R2311 AF38Z-30-11-23
1SBL296001R2322 AF38Z-30-22-23
5/183
5/183
5/82
5/104
5/104
5/82
5/104
5/104
5/82
5/104
5/104
5/82
5/104
5/104
6/46
6/48
6/48
6/46
6/48
6/48
6/46
6/48
6/48
6/46
6/48
6/48
5/182
5/182
5/182
5/182
5/182
5/182
5/182
5/182
5/276
5/276
5/276
5/276
5/276
5/276
5/276
5/266
5/266
5/266
5/266
5/266
5/266
5/266
5/105
5/105
5/105
5/105
5/105
5/105
5/105
5/105
5/82
5/104
5/104
5/82
5/104
5/104
5/82
5/104
5/104
5/82
5/104
5/104
5/276
5/276
5/276
5/276
5/276
5/276
5/276
5/266
5/266
5/266
5/266
5/266
5/266
5/266
5/105
5/105
5/105
5/105
5/105
5/105
5/105
5/105
ABB | 13/3
13
Index
Order code
Index
Order code classification
13
Type
1SBL296201R2000 AF38Z-40-00-20
1SBL296201R2100 AF38Z-40-00-21
1SBL296201R2200 AF38Z-40-00-22
1SBL296201R2300 AF38Z-40-00-23
1SBL296501R2000 AF38Z-22-00-20
1SBL296501R2100 AF38Z-22-00-21
1SBL296501R2200 AF38Z-22-00-22
1SBL296501R2300 AF38Z-22-00-23
1SBL297001R1200 AF38-30-00-12
1SBL297001R1211 AF38-30-11-12
1SBL297001R1222 AF38-30-22-12
1SBL297001R1300 AF38-30-00-13
1SBL297001R1311 AF38-30-11-13
1SBL297001R1322 AF38-30-22-13
1SBL297001R1400 AF38-30-00-14
1SBL297001R1411 AF38-30-11-14
1SBL297001R1422 AF38-30-22-14
1SBL297001R4100 AF38-30-00-41
1SBL297001R4111 AF38-30-11-41
1SBL297001R4122 AF38-30-22-41
1SBL297201R1200 AF38-40-00-12
1SBL297201R1300 AF38-40-00-13
1SBL297201R1400 AF38-40-00-14
1SBL297201R4100 AF38-40-00-41
1SBL297501R1200 AF38-22-00-12
1SBL297501R1300 AF38-22-00-13
1SBL297501R1400 AF38-22-00-14
1SBL297501R4100 AF38-22-00-41
1SBL347001R1100 AF40-30-00-11
1SBL347001R1111 AF40-30-11-11
1SBL347001R1122 AF40-30-22-11
1SBL347001R1200 AF40-30-00-12
1SBL347001R1211 AF40-30-11-12
1SBL347001R1222 AF40-30-22-12
1SBL347001R1300 AF40-30-00-13
1SBL347001R1311 AF40-30-11-13
1SBL347001R1322 AF40-30-22-13
1SBL347001R1400 AF40-30-00-14
1SBL347001R1411 AF40-30-11-14
1SBL347001R1422 AF40-30-22-14
1SBL347001R4100 AF40-30-00-41
1SBL347001R4111 AF40-30-11-41
1SBL347001R4122 AF40-30-22-41
1SBL347201R1100 AF40-40-00-11
1SBL347201R1200 AF40-40-00-12
1SBL347201R1300 AF40-40-00-13
1SBL347201R1400 AF40-40-00-14
1SBL347201R4100 AF40-40-00-41
1SBL347501R1100 AF40-22-00-11
1SBL347501R1200 AF40-22-00-12
1SBL347501R1300 AF40-22-00-13
1SBL347501R1400 AF40-22-00-14
1SBL347501R4100 AF40-22-00-41
1SBL351022R8000 UA50-30-00
1SBL351022R8011 UA50-30-11
1SBL351022R8100 UA50-30-00
1SBL351022R8111 UA50-30-11
1SBL351022R8300 UA50-30-00
1SBL351022R8311 UA50-30-11
1SBL351022R8400 UA50-30-00
1SBL351022R8411 UA50-30-11
1SBL351022R8500 UA50-30-00
1SBL351022R8511 UA50-30-11
1SBL351022R8600 UA50-30-00
1SBL351022R8611 UA50-30-11
1SBL351022R8800 UA50-30-00
1SBL351022R8811 UA50-30-11
1SBL351024R8000 UA50-30-00RA
1SBL351024R8100 UA50-30-00RA
1SBL351024R8300 UA50-30-00RA
1SBL351024R8400 UA50-30-00RA
1SBL351024R8500 UA50-30-00RA
1SBL351024R8600 UA50-30-00RA
1SBL351024R8800 UA50-30-00RA
1SBL367001R1100 AF52-30-00-11
1SBL367001R1111 AF52-30-11-11
1SBL367001R1122 AF52-30-22-11
1SBL367001R1200 AF52-30-00-12
1SBL367001R1211 AF52-30-11-12
1SBL367001R1222 AF52-30-22-12
1SBL367001R1300 AF52-30-00-13
1SBL367001R1311 AF52-30-11-13
1SBL367001R1322 AF52-30-22-13
1SBL367001R1400 AF52-30-00-14
1SBL367001R1411 AF52-30-11-14
1SBL367001R1422 AF52-30-22-14
1SBL367001R4100 AF52-30-00-41
1SBL367001R4111 AF52-30-11-41
1SBL367001R4122 AF52-30-22-41
1SBL367201R1100 AF52-40-00-11
13/4 | ABB
Page
5/183
5/183
5/183
5/183
5/183
5/183
5/183
5/183
5/82
5/104
5/104
5/82
5/104
5/104
5/82
5/104
5/104
5/82
5/104
5/104
5/182
5/182
5/182
5/182
5/182
5/182
5/182
5/182
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/267
5/267
5/267
5/267
5/267
5/267
5/267
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/184
Order code
Type
1SBL367201R1200 AF52-40-00-12
1SBL367201R1300 AF52-40-00-13
1SBL367201R1400 AF52-40-00-14
1SBL367201R4100 AF52-40-00-41
1SBL371022R8000 UA63-30-00
1SBL371022R8011 UA63-30-11
1SBL371022R8100 UA63-30-00
1SBL371022R8111 UA63-30-11
1SBL371022R8300 UA63-30-00
1SBL371022R8311 UA63-30-11
1SBL371022R8400 UA63-30-00
1SBL371022R8411 UA63-30-11
1SBL371022R8500 UA63-30-00
1SBL371022R8511 UA63-30-11
1SBL371022R8600 UA63-30-00
1SBL371022R8611 UA63-30-11
1SBL371022R8800 UA63-30-00
1SBL371022R8811 UA63-30-11
1SBL371024R8000 UA63-30-00RA
1SBL371024R8100 UA63-30-00RA
1SBL371024R8300 UA63-30-00RA
1SBL371024R8400 UA63-30-00RA
1SBL371024R8500 UA63-30-00RA
1SBL371024R8600 UA63-30-00RA
1SBL371024R8800 UA63-30-00RA
1SBL387001R1100 AF65-30-00-11
1SBL387001R1111 AF65-30-11-11
1SBL387001R1122 AF65-30-22-11
1SBL387001R1200 AF65-30-00-12
1SBL387001R1211 AF65-30-11-12
1SBL387001R1222 AF65-30-22-12
1SBL387001R1300 AF65-30-00-13
1SBL387001R1311 AF65-30-11-13
1SBL387001R1322 AF65-30-22-13
1SBL387001R1400 AF65-30-00-14
1SBL387001R1411 AF65-30-11-14
1SBL387001R1422 AF65-30-22-14
1SBL387001R4100 AF65-30-00-41
1SBL387001R4111 AF65-30-11-41
1SBL387001R4122 AF65-30-22-41
1SBL397001R1100 AF80-30-00-11
1SBL397001R1111 AF80-30-11-11
1SBL397001R1122 AF80-30-22-11
1SBL397001R1200 AF80-30-00-12
1SBL397001R1211 AF80-30-11-12
1SBL397001R1222 AF80-30-22-12
1SBL397001R1300 AF80-30-00-13
1SBL397001R1311 AF80-30-11-13
1SBL397001R1322 AF80-30-22-13
1SBL397001R1400 AF80-30-00-14
1SBL397001R1411 AF80-30-11-14
1SBL397001R1422 AF80-30-22-14
1SBL397001R4100 AF80-30-00-41
1SBL397001R4111 AF80-30-11-41
1SBL397001R4122 AF80-30-22-41
1SBL397201R1100 AF80-40-00-11
1SBL397201R1200 AF80-40-00-12
1SBL397201R1300 AF80-40-00-13
1SBL397201R1400 AF80-40-00-14
1SBL397201R4100 AF80-40-00-41
1SBL397501R1100 AF80-22-00-11
1SBL397501R1200 AF80-22-00-12
1SBL397501R1300 AF80-22-00-13
1SBL397501R1400 AF80-22-00-14
1SBL397501R4100 AF80-22-00-41
1SBL407001R1100 AF96-30-00-11
1SBL407001R1111 AF96-30-11-11
1SBL407001R1122 AF96-30-22-11
1SBL407001R1200 AF96-30-00-12
1SBL407001R1211 AF96-30-11-12
1SBL407001R1222 AF96-30-22-12
1SBL407001R1300 AF96-30-00-13
1SBL407001R1311 AF96-30-11-13
1SBL407001R1322 AF96-30-22-13
1SBL407001R1400 AF96-30-00-14
1SBL407001R1411 AF96-30-11-14
1SBL407001R1422 AF96-30-22-14
1SBL407001R4100 AF96-30-00-41
1SBL407001R4111 AF96-30-11-41
1SBL407001R4122 AF96-30-22-41
1SBL411022R8000 UA75-30-00
1SBL411022R8011 UA75-30-11
1SBL411022R8100 UA75-30-00
1SBL411022R8111 UA75-30-11
1SBL411022R8300 UA75-30-00
1SBL411022R8311 UA75-30-11
1SBL411022R8400 UA75-30-00
1SBL411022R8411 UA75-30-11
1SBL411022R8500 UA75-30-00
1SBL411022R8511 UA75-30-11
Page
5/184
5/184
5/184
5/184
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/267
5/267
5/267
5/267
5/267
5/267
5/267
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/106
5/106
5/84
5/107
5/107
5/84
5/107
5/107
5/84
5/107
5/107
5/84
5/107
5/107
5/84
5/107
5/107
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/184
5/84
5/107
5/107
5/84
5/107
5/107
5/84
5/107
5/107
5/84
5/107
5/107
5/84
5/107
5/107
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
5/277
5/278
Order code
Type
1SBL411022R8600 UA75-30-00
1SBL411022R8611 UA75-30-11
1SBL411022R8800 UA75-30-00
1SBL411022R8811 UA75-30-11
1SBL411024R8000 UA75-30-00RA
1SBL411024R8100 UA75-30-00RA
1SBL411024R8300 UA75-30-00RA
1SBL411024R8400 UA75-30-00RA
1SBL411024R8500 UA75-30-00RA
1SBL411024R8600 UA75-30-00RA
1SBL411024R8800 UA75-30-00RA
1SBL411025R8000 GA75-10-00
1SBL411025R8011 GA75-10-11
1SBL411025R8100 GA75-10-00
1SBL411025R8111 GA75-10-11
1SBL411025R8300 GA75-10-00
1SBL411025R8311 GA75-10-11
1SBL411025R8400 GA75-10-00
1SBL411025R8411 GA75-10-11
1SBL411025R8500 GA75-10-00
1SBL411025R8511 GA75-10-11
1SBL411025R8600 GA75-10-00
1SBL411025R8611 GA75-10-11
1SBL411025R8800 GA75-10-00
1SBL411025R8811 GA75-10-11
1SBL419025R8000 GAE75-10-00
1SBL419025R8011 GAE75-10-11
1SBL419025R8100 GAE75-10-00
1SBL419025R8111 GAE75-10-11
1SBL419025R8300 GAE75-10-00
1SBL419025R8311 GAE75-10-11
1SBL419025R8400 GAE75-10-00
1SBL419025R8411 GAE75-10-11
1SBL419025R8600 GAE75-10-00
1SBL419025R8611 GAE75-10-11
1SBL419025R8700 GAE75-10-00
1SBL419025R8711 GAE75-10-11
1SBL419025R8800 GAE75-10-00
1SBL419025R8811 GAE75-10-11
1SBL419025R8900 GAE75-10-00
1SBL419025R8911 GAE75-10-11
1SBN010010R1001 CA5-01
1SBN010010R1010 CA5-10
1SBN010011R1001 CC5-01
1SBN010011R1010 CC5-10
1SBN010013R1001 CB5-01
1SBN010013R1010 CB5-10
1SBN010015R1001 CE5-01D0.1
1SBN010015R1010 CE5-10D0.1
1SBN010016R1001 CE5-01W0.1
1SBN010016R1010 CE5-10W0.1
1SBN010017R1001 CE5-01D2
1SBN010017R1010 CE5-10D2
1SBN010018R1001 CE5-01W2
1SBN010018R1010 CE5-10W2
1SBN010020R1011 CAL5-11
1SBN010040R1004 CA5-04E
1SBN010040R1018 CA5-11/11E
1SBN010040R1022 CA5-22E
1SBN010040R1031 CA5-31E
1SBN010040R1040 CA5-40E
1SBN010040R1104 CA5-04M
1SBN010040R1113 CA5-13M
1SBN010040R1118 CA5-11/11M
1SBN010040R1122 CA5-22M
1SBN010040R1131 CA5-31M
1SBN010110R1001 CA4-01
1SBN010110R1010 CA4-10
1SBN010110T1001 CA4-01-T
1SBN010110T1010 CA4-10-T
1SBN010111R1001 CC4-01
1SBN010111R1010 CC4-10
1SBN010119R1001 CA4-01S
1SBN010119R1010 CA4-10S
1SBN010119T1001 CA4-01S-T
1SBN010119T1010 CA4-10S-T
1SBN010120R1011 CAL4-11
1SBN010120T1011 CAL4-11-T
1SBN010130R1011 CAL4-11S
1SBN010140R1004 CA4-04E
1SBN010140R1022 CA4-22E
1SBN010140R1031 CA4-31E
1SBN010140R1040 CA4-40E
1SBN010140R1104 CA4-04M
1SBN010140R1113 CA4-13M
1SBN010140R1122 CA4-22M
1SBN010140R1131 CA4-31M
1SBN010140R1204 CA4-04N
1SBN010140R1213 CA4-13N
1SBN010140R1222 CA4-22N
Page
5/277
5/278
5/277
5/278
5/267
5/267
5/267
5/267
5/267
5/267
5/267
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/242
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/243
5/358
5/358
5/358
5/358
5/340
5/340
5/360
5/360
5/360
5/360
5/360
5/360
5/360
5/360
5/358
5/358
5/358
5/358
5/358
5/358
5/358
5/358
5/358
5/358
5/358
5/87
5/87
5/87
5/87
5/322
5/322
6/51
6/51
6/51
6/51
5/322
5/322
6/51
5/187
5/87
5/187
5/187
5/322
5/322
5/87
5/322
5/307
5/307
5/307
Index
Order code
Index
Order code classification
Type
1SBN010140R1231 CA4-31N
1SBN010140R1240 CA4-40N
1SBN010140R1322 CA4-22U
1SBN010140R1331 CA4-31U
1SBN010140R1340 CA4-40U
1SBN010145R1022 CA4-22ES
1SBN010145R1031 CA4-31ES
1SBN010145R1040 CA4-40ES
1SBN010145R1122 CA4-22MS
1SBN010145R1131 CA4-31MS
1SBN010145R1222 CA4-22NS
1SBN010145R1231 CA4-31NS
1SBN010145R1240 CA4-40NS
1SBN010151R1011 CAT4-11E
1SBN010151R1111 CAT4-11M
1SBN010151R1311 CAT4-11U
1SBN010153R1011 CAT4-11ES
1SBN010153R1111 CAT4-11MS
1SBN010153R1311 CAT4-11US
1SBN011010T1001 CA3-01
1SBN011010T1010 CA3-10
1SBN011019T1001 CA3-01S
1SBN011019T1010 CA3-10S
1SBN020112R1000 TEF4-ON
1SBN020113R1000 TEF4S-ON
1SBN020114R1000 TEF4-OFF
1SBN020115R1000 TEF4S-OFF
1SBN020312R1000 TEF5-ON
1SBN020314R1000 TEF5-OFF
1SBN021012R1000 TEF3-ON
1SBN021014R1000 TEF3-OFF
1SBN030105T1000 VM4
1SBN030111R1000 VEM4
1SBN030210R1000 VE5-2
1SBN031005T1000 VM3
1SBN033405T1000 VM96-4
1SBN050010R1000 RV5/50
1SBN050010R1001 RV5/133
1SBN050010R1002 RV5/250
1SBN050010R1003 RV5/440
1SBN050020R1000 RT5/32
1SBN050020R1001 RT5/65
1SBN050020R1002 RT5/90
1SBN050020R1003 RT5/150
1SBN050020R1004 RT5/264
1SBN050100R1000 RC5-1/50
1SBN050100R1001 RC5-1/133
1SBN050100R1002 RC5-1/250
1SBN050100R1003 RC5-1/440
1SBN050200R1000 RC5-2/50
1SBN050200R1001 RC5-2/133
1SBN050200R1002 RC5-2/250
1SBN050200R1003 RC5-2/440
1SBN060300R1000 RA5-1
1SBN060300T1000 RA5-1
1SBN070156T1000 LDC4
1SBN070157T1000 LDC4S
1SBN071303T1000 LY16-4
1SBN071305R1000 LF16-4
1SBN071306R1000 LG16-4
1SBN072303T1000 LY38-4
1SBN072304R1000 LH38-4
1SBN072305R1000 LF38-4
1SBN072308R1000 LD38-4
1SBN073508R1000 LD75
1SBN073552R1002 LK75-F
1SBN073552R1003 LK75-L
1SBN080906R1001 BEA7/325
1SBN080906R1002 BEA7/132
1SBN081006T1000 BEA16-3
1SBN081012R1000 BER16C-3
1SBN081018R2000 BEY16C-3
1SBN081020R1000 BEA16-3U
1SBN081306T1000 BEA16-4
1SBN081311R1000 BER16-4
1SBN081313R2000 BEY16-4
1SBN082306T1000 BEA26-4
1SBN082306T2000 BEA38-4
1SBN082311R1000 BER38-4
1SBN082713R2000 BEY38-4
1SBN083411R1000 BER65-4
1SBN083413R2000 BEY65-4
1SBN083911R1000 BER96-4
1SBN083913R2000 BEY96-4
1SBN101035R1000 FR16AS-12VARS
1SBN110000R1000 BA5-50
1SBN110108T1000 BX4
1SBN110109W1000 BX4-CA
1SBN110120W1000 BB4
1SBN110122T1000 BDT4
Page
5/307
5/307
5/87
5/322
5/322
6/51
6/51
6/51
6/51
6/51
6/73
6/73
6/73
5/87
5/87
5/87
6/51
6/51
6/51
4/37
4/37
6/9
6/9
5/87
6/51
5/87
6/51
5/365
5/365
4/37
4/37
5/87
5/87
5/368
4/37
5/87
4/37
4/37
4/37
4/37
4/37
4/37
4/37
4/37
4/37
4/37
4/37
4/37
4/37
5/372
5/372
5/372
5/372
5/374
5/374
5/307
6/51
5/349
5/349
5/349
5/349
5/349
5/349
5/346
5/378
5/379
5/379
3/39
3/39
4/37
4/37
4/37
6/9
5/87
5/87
5/87
5/87
5/87
5/87
5/87
5/87
5/87
5/87
5/87
8/2
3/39
5/307
5/307
5/338
4/82
Order code
Type
Page
1SBN111020R1000 BB3
4/82
1SBN111403R1000 BP16
5/371
1SBN112303T1000 BP38-4
5/345
1SBN113403T1000 BP65-4
5/345
1SBN113903T1000 BP96-4
5/345
1SBN151410R8006 ZA16
5/380
1SBN151410R8106 ZA16
5/380
1SBN151410R8306 ZA16
5/380
1SBN151410R8406 ZA16
5/380
1SBN151410R8506 ZA16
5/380
1SBN151410R8606 ZA16
5/380
1SBN151410R8806 ZA16
5/380
1SBN152410R8006 ZA40
5/380
1SBN152410R8106 ZA40
5/380
1SBN152410R8306 ZA40
5/380
1SBN152410R8406 ZA40
5/380
1SBN152410R8506 ZA40
5/380
1SBN152410R8606 ZA40
5/380
1SBN152410R8806 ZA40
5/380
1SBN153510R8006 ZA75
5/380
1SBN153510R8106 ZA75
5/380
1SBN153510R8306 ZA75
5/380
1SBN153510R8406 ZA75
5/380
1SBN153510R8506 ZA75
5/380
1SBN153510R8606 ZA75
5/380
1SBN153510R8806 ZA75
5/380
1SBN163502R1000 ZLU50
5/380
1SBN163702R1000 ZLU63
5/380
1SBN164102R1000 ZLU75
5/380
1SCA101647R1001 OXS6X85
2/38
1SCA101655R1001 OXS6X130
2/38
1SCA101659R1001 OXS6X180
2/38
1SCA108043R1001 OXS6X105
2/38
1SFA616162R1014 KPR-101L
7/4
1SFA739001R1000 E1250DU-1250
7/48
1SFL427001R1100 AF116-30-00-11 5/88
1SFL427001R1111 AF116-30-11-11 5/94
1SFL427001R1122 AF116-30-22-11 5/110
1SFL427001R1200 AF116-30-00-12 5/88
1SFL427001R1211 AF116-30-11-12 5/94
1SFL427001R1222 AF116-30-22-12 5/110
1SFL427001R1300 AF116-30-00-13 5/88
1SFL427001R1311 AF116-30-11-13 5/94
1SFL427001R1322 AF116-30-22-13 5/110
1SFL427001R1400 AF116-30-00-14 5/88
1SFL427001R1411 AF116-30-11-14 5/94
1SFL427001R1422 AF116-30-22-14 5/110
1SFL427001R3300 AF116-30-00-33 5/89
1SFL427001R3311 AF116-30-11-33 5/95
1SFL427001R3322 AF116-30-22-33 5/111
1SFL427001R3400 AF116-30-00-34 5/89
1SFL427001R3411 AF116-30-11-34 5/95
1SFL427001R3422 AF116-30-22-34 5/111
1SFL427002R1100 AF116-30-00B-11 5/88
1SFL427002R1111 AF116-30-11B-11 5/94
1SFL427002R1122 AF116-30-22B-11 5/110
1SFL427002R1200 AF116-30-00B-12 5/88
1SFL427002R1211 AF116-30-11B-12 5/94
1SFL427002R1222 AF116-30-22B-12 5/110
1SFL427002R1300 AF116-30-00B-13 5/88
1SFL427002R1311 AF116-30-11B-13 5/94
1SFL427002R1322 AF116-30-22B-13 5/110
1SFL427002R1400 AF116-30-00B-14 5/88
1SFL427002R1411 AF116-30-11B-14 5/94
1SFL427002R1422 AF116-30-22B-14 5/110
1SFL427002R3300 AF116-30-00B-33 5/89
1SFL427002R3311 AF116-30-11B-33 5/95
1SFL427002R3322 AF116-30-22B-33 5/111
1SFL427002R3400 AF116-30-00B-34 5/89
1SFL427002R3411 AF116-30-11B-34 5/95
1SFL427002R3422 AF116-30-22B-34 5/111
1SFL427101R1100 AF116-40-00-11 5/188
1SFL427101R1111 AF116-40-11-11 5/192
1SFL427101R1122 AF116-40-22-11 5/196
1SFL427101R1200 AF116-40-00-12 5/188
1SFL427101R1211 AF116-40-11-12 5/192
1SFL427101R1222 AF116-40-22-12 5/196
1SFL427101R1300 AF116-40-00-13 5/188
1SFL427101R1311 AF116-40-11-13 5/192
1SFL427101R1322 AF116-40-22-13 5/196
1SFL427101R1400 AF116-40-00-14 5/188
1SFL427101R1411 AF116-40-11-14 5/192
1SFL427101R1422 AF116-40-22-14 5/196
1SFL427102R1100 AF116-40-00B-11 5/188
1SFL427102R1111 AF116-40-11B-11 5/192
1SFL427102R1122 AF116-40-22B-11 5/196
1SFL427102R1200 AF116-40-00B-12 5/188
1SFL427102R1211 AF116-40-11B-12 5/192
1SFL427102R1222 AF116-40-22B-12 5/196
1SFL427102R1300 AF116-40-00B-13 5/188
Order code
Type
Page
1SFL427102R1311 AF116-40-11B-13 5/192
1SFL427102R1322 AF116-40-22B-13 5/196
1SFL427102R1400 AF116-40-00B-14 5/188
1SFL427102R1411 AF116-40-11B-14 5/192
1SFL427102R1422 AF116-40-22B-14 5/196
1SFL431022R8000 UA95-30-00
5/279
1SFL431022R8011 UA95-30-11
5/280
1SFL431022R8100 UA95-30-00
5/279
1SFL431022R8111 UA95-30-11
5/280
1SFL431022R8300 UA95-30-00
5/279
1SFL431022R8311 UA95-30-11
5/280
1SFL431022R8400 UA95-30-00
5/279
1SFL431022R8411 UA95-30-11
5/280
1SFL431022R8500 UA95-30-00
5/279
1SFL431022R8511 UA95-30-11
5/280
1SFL431022R8600 UA95-30-00
5/279
1SFL431022R8611 UA95-30-11
5/280
1SFL431022R8800 UA95-30-00
5/279
1SFL431022R8811 UA95-30-11
5/280
1SFL431024R8000 UA95-30-00RA 5/268
1SFL431024R8100 UA95-30-00RA 5/268
1SFL431024R8300 UA95-30-00RA 5/268
1SFL431024R8400 UA95-30-00RA 5/268
1SFL431024R8500 UA95-30-00RA 5/268
1SFL431024R8600 UA95-30-00RA 5/268
1SFL431024R8800 UA95-30-00RA 5/268
1SFL447001R1100 AF140-30-00-11 5/88
1SFL447001R1111 AF140-30-11-11 5/94
1SFL447001R1122 AF140-30-22-11 5/110
1SFL447001R1200 AF140-30-00-12 5/88
1SFL447001R1211 AF140-30-11-12 5/94
1SFL447001R1222 AF140-30-22-12 5/110
1SFL447001R1300 AF140-30-00-13 5/88
1SFL447001R1311 AF140-30-11-13 5/94
1SFL447001R1322 AF140-30-22-13 5/110
1SFL447001R1400 AF140-30-00-14 5/88
1SFL447001R1411 AF140-30-11-14 5/94
1SFL447001R1422 AF140-30-22-13 5/110
1SFL447001R3300 AF140-30-00-33 5/89
1SFL447001R3311 AF140-30-11-33 5/95
1SFL447001R3322 AF140-30-22-33 5/111
1SFL447001R3400 AF140-30-00-34 5/89
1SFL447001R3411 AF140-30-11-34 5/95
1SFL447001R3422 AF140-30-22-33 5/111
1SFL447002R1100 AF140-30-00B-11 5/88
1SFL447002R1111 AF140-30-11B-11 5/94
1SFL447002R1122 AF140-30-22B-11 5/110
1SFL447002R1200 AF140-30-00B-12 5/88
1SFL447002R1211 AF140-30-11B-12 5/94
1SFL447002R1222 AF140-30-22B-12 5/110
1SFL447002R1300 AF140-30-00B-13 5/88
1SFL447002R1311 AF140-30-11B-13 5/94
1SFL447002R1322 AF140-30-22B-13 5/110
1SFL447002R1400 AF140-30-00B-14 5/88
1SFL447002R1411 AF140-30-11B-14 5/94
1SFL447002R1422 AF140-30-22B-14 5/110
1SFL447002R3300 AF140-30-00B-33 5/89
1SFL447002R3311 AF140-30-11B-33 5/95
1SFL447002R3322 AF140-30-22B-33 5/111
1SFL447002R3400 AF140-30-00B-34 5/89
1SFL447002R3411 AF140-30-11B-34 5/95
1SFL447002R3422 AF140-30-22B-34 5/111
1SFL447101R1100 AF140-40-00-11 5/188
1SFL447101R1111 AF140-40-11-11 5/192
1SFL447101R1122 AF140-40-22-11 5/196
1SFL447101R1200 AF140-40-00-12 5/188
1SFL447101R1211 AF140-40-11-12 5/192
1SFL447101R1222 AF140-40-22-12 5/196
1SFL447101R1300 AF140-40-00-13 5/188
1SFL447101R1311 AF140-40-11-13 5/192
1SFL447101R1322 AF140-40-22-13 5/196
1SFL447101R1400 AF140-40-00-14 5/188
1SFL447101R1411 AF140-40-11-14 5/192
1SFL447101R1422 AF140-40-22-14 5/196
1SFL447102R1100 AF140-40-00B-11 5/188
1SFL447102R1111 AF140-40-11B-11 5/192
1SFL447102R1122 AF140-40-22B-11 5/196
1SFL447102R1200 AF140-40-00B-12 5/188
1SFL447102R1211 AF140-40-11B-12 5/192
1SFL447102R1222 AF140-40-22B-12 5/196
1SFL447102R1300 AF140-40-00B-13 5/188
1SFL447102R1311 AF140-40-11B-13 5/192
1SFL447102R1322 AF140-40-22B-13 5/196
1SFL447102R1400 AF140-40-00B-14 5/188
1SFL447102R1411 AF140-40-11B-14 5/192
1SFL447102R1422 AF140-40-22B-14 5/196
1SFL451022R8000 UA110-30-00
5/279
1SFL451022R8011 UA110-30-11
5/280
1SFL451022R8100 UA110-30-00
5/279
1SFL451022R8111 UA110-30-11
5/280
ABB | 13/5
13
Index
Order code
Index
Order code classification
13
Type
Page
1SFL451022R8300 UA110-30-00
5/279
1SFL451022R8311 UA110-30-11
5/280
1SFL451022R8400 UA110-30-00
5/279
1SFL451022R8411 UA110-30-11
5/280
1SFL451022R8500 UA110-30-00
5/279
1SFL451022R8511 UA110-30-11
5/280
1SFL451022R8600 UA110-30-00
5/279
1SFL451022R8611 UA110-30-11
5/280
1SFL451022R8800 UA110-30-00
5/279
1SFL451022R8811 UA110-30-11
5/280
1SFL451024R8000 UA110-30-00RA 5/268
1SFL451024R8100 UA110-30-00RA 5/268
1SFL451024R8300 UA110-30-00RA 5/268
1SFL451024R8400 UA110-30-00RA 5/268
1SFL451024R8500 UA110-30-00RA 5/268
1SFL451024R8600 UA110-30-00RA 5/268
1SFL451024R8800 UA110-30-00RA 5/268
1SFL467001R1100 AF146-30-00-11 5/88
1SFL467001R1111 AF146-30-11-11 5/94
1SFL467001R1122 AF146-30-22-11 5/110
1SFL467001R1200 AF146-30-00-12 5/88
1SFL467001R1211 AF146-30-11-12 5/94
1SFL467001R1222 AF146-30-22-12 5/110
1SFL467001R1300 AF146-30-00-13 5/88
1SFL467001R1311 AF146-30-11-13 5/94
1SFL467001R1322 AF146-30-22-13 5/110
1SFL467001R1400 AF146-30-00-14 5/88
1SFL467001R1411 AF146-30-11-14 5/94
1SFL467001R1422 AF146-30-22-14 5/110
1SFL467001R3300 AF146-30-00-33 5/89
1SFL467001R3311 AF146-30-11-33 5/95
1SFL467001R3322 AF146-30-22-33 5/111
1SFL467001R3400 AF146-30-00-34 5/89
1SFL467001R3411 AF146-30-11-34 5/95
1SFL467001R3422 AF146-30-22-34 5/111
1SFL467002R1100 AF146-30-00B-11 5/88
1SFL467002R1111 AF146-30-11B-11 5/94
1SFL467002R1122 AF146-30-22B-11 5/110
1SFL467002R1200 AF146-30-00B-12 5/88
1SFL467002R1211 AF146-30-11B-12 5/94
1SFL467002R1222 AF146-30-22B-12 5/110
1SFL467002R1300 AF146-30-00B-13 5/88
1SFL467002R1311 AF146-30-11B-13 5/94
1SFL467002R1322 AF146-30-22B-13 5/110
1SFL467002R1400 AF146-30-00B-14 5/88
1SFL467002R1411 AF146-30-11B-14 5/94
1SFL467002R1422 AF146-30-22B-14 5/110
1SFL467002R3300 AF146-30-00B-33 5/89
1SFL467002R3311 AF146-30-11B-33 5/95
1SFL467002R3322 AF146-30-22B-33 5/111
1SFL467002R3400 AF146-30-00B-34 5/89
1SFL467002R3422 AF146-30-22B-34 5/111
1SFL487002R1100 AF190-30-00-11 5/90
1SFL487002R1111 AF190-30-11-11 5/96
1SFL487002R1122 AF190-30-22-11 5/112
1SFL487002R1200 AF190-30-00-12 5/90
1SFL487002R1211 AF190-30-11-12 5/96
1SFL487002R1222 AF190-30-22-12 5/112
1SFL487002R1300 AF190-30-00-13 5/90
1SFL487002R1311 AF190-30-11-13 5/96
1SFL487002R1322 AF190-30-22-13 5/112
1SFL487002R1400 AF190-30-00-14 5/90
1SFL487002R1411 AF190-30-11-14 5/96
1SFL487002R1422 AF190-30-22-14 5/112
1SFL487002R3300 AF190-30-00-33 5/91
1SFL487002R3311 AF190-30-11-33 5/97
1SFL487002R3322 AF190-30-22-33 5/113
1SFL487002R3400 AF190-30-00-34 5/91
1SFL487002R3411 AF190-30-11-34 5/97
1SFL487002R3422 AF190-30-22-34 5/113
1SFL487102R1100 AF190-40-00-11 5/189
1SFL487102R1111 AF190-40-11-11 5/193
1SFL487102R1122 AF190-40-22-11 5/197
1SFL487102R1200 AF190-40-00-12 5/189
1SFL487102R1211 AF190-40-11-12 5/193
1SFL487102R1222 AF190-40-22-12 5/197
1SFL487102R1300 AF190-40-00-13 5/189
1SFL487102R1311 AF190-40-11-13 5/193
1SFL487102R1322 AF190-40-22-13 5/197
1SFL487102R1400 AF190-40-00-14 5/189
1SFL487102R1411 AF190-40-11-14 5/193
1SFL487102R1422 AF190-40-22-14 5/197
1SFL497025R6911 GAF185-10-11 5/244
1SFL497025R7011 GAF185-10-11 5/244
1SFL497025R7211 GAF185-10-11 5/244
1SFL527002R1100 AF205-30-00-11 5/90
1SFL527002R1111 AF205-30-11-11 5/96
1SFL527002R1122 AF205-30-22-11 5/112
1SFL527002R1200 AF205-30-00-12 5/90
1SFL527002R1211 AF205-30-11-12 5/96
13/6 | ABB
Order code
Type
1SFL527002R1222 AF205-30-22-12
1SFL527002R1300 AF205-30-00-13
1SFL527002R1311 AF205-30-11-13
1SFL527002R1322 AF205-30-22-13
1SFL527002R1400 AF205-30-00-14
1SFL527002R1411 AF205-30-11-14
1SFL527002R1422 AF205-30-22-14
1SFL527002R3300 AF205-30-00-33
1SFL527002R3311 AF205-30-11-33
1SFL527002R3322 AF205-30-22-33
1SFL527002R3400 AF205-30-00-34
1SFL527002R3411 AF205-30-11-34
1SFL527002R3422 AF205-30-22-34
1SFL527102R1100 AF205-40-00-11
1SFL527102R1111 AF205-40-11-11
1SFL527102R1122 AF205-40-22-11
1SFL527102R1200 AF205-40-00-12
1SFL527102R1211 AF205-40-11-12
1SFL527102R1222 AF205-40-22-12
1SFL527102R1300 AF205-40-00-13
1SFL527102R1311 AF205-40-11-13
1SFL527102R1322 AF205-40-22-13
1SFL527102R1400 AF205-40-00-14
1SFL527102R1411 AF205-40-11-14
1SFL527102R1422 AF205-40-22-14
1SFL547002R1100 AF265-30-00-11
1SFL547002R1111 AF265-30-11-11
1SFL547002R1122 AF265-30-22-11
1SFL547002R1200 AF265-30-00-12
1SFL547002R1211 AF265-30-11-12
1SFL547002R1222 AF265-30-22-12
1SFL547002R1300 AF265-30-00-13
1SFL547002R1311 AF265-30-11-13
1SFL547002R1322 AF265-30-22-13
1SFL547002R1400 AF265-30-00-14
1SFL547002R1411 AF265-30-11-14
1SFL547002R1422 AF265-30-22-14
1SFL547002R3300 AF265-30-00-33
1SFL547002R3311 AF265-30-11-33
1SFL547002R3322 AF265-30-22-33
1SFL547002R3400 AF265-30-00-34
1SFL547002R3411 AF265-30-11-34
1SFL547002R3422 AF265-30-22-34
1SFL547102R1100 AF265-40-00-11
1SFL547102R1111 AF265-40-11-11
1SFL547102R1122 AF265-40-22-11
1SFL547102R1200 AF265-40-00-12
1SFL547102R1211 AF265-40-11-12
1SFL547102R1222 AF265-40-22-12
1SFL547102R1300 AF265-40-00-13
1SFL547102R1311 AF265-40-11-13
1SFL547102R1322 AF265-40-22-13
1SFL547102R1400 AF265-40-00-14
1SFL547102R1411 AF265-40-11-14
1SFL547102R1422 AF265-40-22-14
1SFL557025R6911 GAF300-10-11
1SFL557025R7011 GAF300-10-11
1SFL557025R7211 GAF300-10-11
1SFL577001R6811 AF400-30-11
1SFL577001R6822 AF400-30-22
1SFL577001R6911 AF400-30-11
1SFL577001R6922 AF400-30-22
1SFL577001R7011 AF400-30-11
1SFL577001R7022 AF400-30-22
1SFL577001R7111 AF400-30-11
1SFL577001R7122 AF400-30-22
1SFL587002R1100 AF305-30-00-11
1SFL587002R1111 AF305-30-11-11
1SFL587002R1122 AF305-30-22-11
1SFL587002R1200 AF305-30-00-12
1SFL587002R1211 AF305-30-11-12
1SFL587002R1222 AF305-30-22-12
1SFL587002R1300 AF305-30-00-13
1SFL587002R1311 AF305-30-11-13
1SFL587002R1322 AF305-30-22-13
1SFL587002R1400 AF305-30-00-14
1SFL587002R1411 AF305-30-11-14
1SFL587002R1422 AF305-30-22-14
1SFL587002R3300 AF305-30-00-33
1SFL587002R3311 AF305-30-11-33
1SFL587002R3322 AF305-30-22-33
1SFL587002R3400 AF305-30-00-34
1SFL587002R3411 AF305-30-11-34
1SFL587002R3422 AF305-30-22-34
1SFL587102R1100 AF305-40-00-11
1SFL587102R1111 AF305-40-11-11
1SFL587102R1122 AF305-40-22-11
1SFL587102R1200 AF305-40-00-12
1SFL587102R1211 AF305-40-11-12
1SFL587102R1222 AF305-40-22-12
Page
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/91
5/97
5/113
5/91
5/97
5/113
5/189
5/193
5/197
5/189
5/193
5/197
5/189
5/193
5/197
5/189
5/193
5/197
5/90
5/96
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/91
5/97
5/113
5/91
5/97
5/113
5/189
5/193
5/197
5/189
5/193
5/197
5/189
5/193
5/197
5/189
5/193
5/197
5/244
5/244
5/244
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/90
5/96
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/91
5/97
5/113
5/91
5/97
5/113
5/189
5/193
5/197
5/189
5/193
5/197
Order code
Type
1SFL587102R1300 AF305-40-00-13
1SFL587102R1311 AF305-40-11-13
1SFL587102R1322 AF305-40-22-13
1SFL587102R1400 AF305-40-00-14
1SFL587102R1411 AF305-40-11-14
1SFL587102R1422 AF305-40-22-14
1SFL597001R6811 AF460-30-11
1SFL597001R6822 AF460-30-22
1SFL597001R6911 AF460-30-11
1SFL597001R6922 AF460-30-22
1SFL597001R7011 AF460-30-11
1SFL597001R7022 AF460-30-22
1SFL597001R7111 AF460-30-11
1SFL597001R7122 AF460-30-22
1SFL597025R6811 GAF460-10-11
1SFL597025R6911 GAF460-10-11
1SFL597025R7011 GAF460-10-11
1SFL597025R7111 GAF460-10-11
1SFL607002R1100 AF370-30-00-11
1SFL607002R1111 AF370-30-11-11
1SFL607002R1122 AF370-30-22-11
1SFL607002R1200 AF370-30-00-12
1SFL607002R1211 AF370-30-11-12
1SFL607002R1222 AF370-30-22-12
1SFL607002R1300 AF370-30-00-13
1SFL607002R1311 AF370-30-11-13
1SFL607002R1322 AF370-30-22-13
1SFL607002R1400 AF370-30-00-14
1SFL607002R1411 AF370-30-11-14
1SFL607002R1422 AF370-30-22-14
1SFL607002R3300 AF370-30-00-33
1SFL607002R3311 AF370-30-11-33
1SFL607002R3322 AF370-30-22-33
1SFL607002R3400 AF370-30-00-34
1SFL607002R3411 AF370-30-11-34
1SFL607002R3422 AF370-30-22-34
1SFL607102R1100 AF370-40-00-11
1SFL607102R1111 AF370-40-11-11
1SFL607102R1122 AF370-40-22-11
1SFL607102R1200 AF370-40-00-12
1SFL607102R1211 AF370-40-11-12
1SFL607102R1222 AF370-40-22-12
1SFL607102R1300 AF370-40-00-13
1SFL607102R1311 AF370-40-11-13
1SFL607102R1322 AF370-40-22-13
1SFL607102R1400 AF370-40-00-14
1SFL607102R1411 AF370-40-11-14
1SFL607102R1422 AF370-40-22-14
1SFL617001R6811 AF580-30-11
1SFL617001R6822 AF580-30-22
1SFL617001R6911 AF580-30-11
1SFL617001R6922 AF580-30-22
1SFL617001R7011 AF580-30-11
1SFL617001R7022 AF580-30-22
1SFL617001R7111 AF580-30-11
1SFL617001R7122 AF580-30-22
1SFL637001R6811 AF750-30-11
1SFL637001R6822 AF750-30-22
1SFL637001R6911 AF750-30-11
1SFL637001R6922 AF750-30-22
1SFL637001R7011 AF750-30-11
1SFL637001R7022 AF750-30-22
1SFL637001R7111 AF750-30-11
1SFL637001R7122 AF750-30-22
1SFL637025R6811 GAF750-10-11
1SFL637025R6911 GAF750-10-11
1SFL637025R7011 GAF750-10-11
1SFL637025R7111 GAF750-10-11
1SFL647001R6811 AF1250-30-11
1SFL647001R6822 AF1250-30-22
1SFL647001R6911 AF1250-30-11
1SFL647001R6922 AF1250-30-22
1SFL647001R7011 AF1250-30-11
1SFL647001R7022 AF1250-30-22
1SFL647001R7111 AF1250-30-11
1SFL647001R7122 AF1250-30-22
1SFL647025R6811 GAF1250-10-11
1SFL647025R6911 GAF1250-10-11
1SFL647025R7011 GAF1250-10-11
1SFL647025R7111 GAF1250-10-11
1SFL657001R7011 AF1350-30-11
1SFL657001R7022 AF1350-30-22
1SFL667001R7011 AF2650-30-11
1SFL667001R7022 AF2650-30-22
1SFL677001R7011 AF1650-30-11
1SFL677001R7022 AF1650-30-22
1SFL677025R7011 GAF1650-10-11
1SFL707001R7011 AF2050-30-11
1SFL707001R7022 AF2050-30-22
1SFL707025R7011 GAF2050-10-11
Page
5/189
5/193
5/197
5/189
5/193
5/197
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/245
5/245
5/245
5/245
5/90
5/96
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/90
5/96
5/112
5/91
5/97
5/113
5/91
5/97
5/113
5/189
5/193
5/197
5/189
5/193
5/197
5/189
5/193
5/197
5/189
5/193
5/197
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/100
5/116
5/245
5/245
5/245
5/245
5/101
5/117
5/101
5/117
5/101
5/117
5/101
5/117
5/246
5/246
5/246
5/246
5/101
5/117
5/101
5/117
5/101
5/117
5/246
5/101
5/117
5/246
Index
Order code
Index
Order code classification
Type
Page
1SFN010716R1001 CEL18-01
5/247
1SFN010716R1010 CEL18-10
5/247
1SFN010720R1011 CAL18-11
5/103
1SFN010720R3311 CAL18-11B
5/103
1SFN010820R1011 CAL19-11
5/93
1SFN010820R3311 CAL19-11B
5/93
1SFN030300R1000 VM19
5/93
1SFN034403R1000 VM140/190
5/93
1SFN035203R1000 VM205/265
5/93
1SFN035700R1000 VM750H
5/103
1SFN035701R1000 VM750V
5/338
1SFN036503R1000 VM1650H
5/103
1SFN074203R1000 LY140
5/349
1SFN074207R1000 LW140
5/93
1SFN074208R1000 LD146-30
5/348
1SFN074208R2000 LD146-40
5/348
1SFN074210R1000 LX140
5/93
1SFN074211R1000 LL146-30
5/348
1SFN074211R2000 LL146-40
5/348
1SFN074307R1000 LW110
5/378
1SFN074703R1000 LY185
5/349
1SFN074712R1000 LP185
5/247
1SFN074807R1000 LW205
5/93
1SFN074807R2000 LW205-40
5/191
1SFN074810R1000 LX205
5/93
1SFN074811R2000 LL205-40
5/348
1SFN075103R1000 LY300
5/349
1SFN075112R1000 LP300
5/247
1SFN075407R1000 LW370
5/93
1SFN075407R2000 LW370-40
5/191
1SFN075410R1000 LX370
5/93
1SFN075411R2000 LL370-40
5/348
1SFN075703R1000 LY460
5/349
1SFN075707R1000 LW460
5/103
1SFN075710R1000 LX460
5/103
1SFN075712R1000 LP460
5/247
1SFN076103R1000 LY750
5/349
1SFN076107R1000 LW750
5/103
1SFN076110R1000 LX750
5/103
1SFN076112R1000 LP750
5/247
1SFN076407R1000 LW1250
5/103
1SFN076412R1000 LP1250
5/247
1SFN076512R1000 LP2050
5/247
1SFN084206R1000 BEA140/XT2
5/352
1SFN084206R1001 BEA140/XT4
5/352
1SFN084211R1000 BER140-4
5/350
1SFN084214R1000 BEP140-30
5/350
1SFN084214R2000 BEP140-40
5/350
1SFN084413R1000 BEY140-4
5/351
1SFN084806R1000 BEA205/XT4
5/352
1SFN084806R1001 BEA205/T4
5/352
1SFN084811R1000 BER205-4
5/350
1SFN084813R1000 BEY190-4
5/351
1SFN084814R1000 BEP205-30
5/350
1SFN084814R2000 BEP205-40
5/350
1SFN085213R1000 BEY205-4
5/351
1SFN085406R1000 BEA370/T5
5/352
1SFN085411R1000 BER370-4
5/350
1SFN085413R1000 BEY265-4
5/351
1SFN085414R1000 BEP370-30
5/350
1SFN085414R2000 BEP370-40
5/350
1SFN085701R1000 BEM460-30
5/350
1SFN085703R1000 BED460
5/351
1SFN085704R1000 BES460
5/350
1SFN085708R1000 BEF460/OESA400
5/352
1SFN085709R1000 OESA460H/OESA400
5/352
1SFN085813R1000 BEY370-4
5/351
1SFN085903R1000 BED580
5/351
1SFN085907R1000 BEA460H/T4
5/352
1SFN086101R1000 BEM750-30
5/350
1SFN086103R1000 BED750
5/351
1SFN086104R1000 BES750
5/350
1SFN086106R1000 BEA750/T6
5/352
1SFN086106R1001 BEA750/T5
5/352
1SFN086106R1002 BEA750D/T6
5/352
1SFN086106R1003 BEA750D/T5
5/352
1SFN086108R1000 BEF750/OESA800
5/352
1SFN094200R1000 PR146-1
5/354
1SFN094900R1000 PR210-1
5/354
1SFN095100R1001 PR185-2
5/354
1SFN095300R1000 PR300-1
5/354
1SFN095300R1001 PR300-2
5/354
1SFN095700R1000 PR460-1
5/354
1SFN095700R1001 PR460-2
5/354
1SFN095700R1002 PR400-2
5/354
1SFN095701R1000 PN460-21
5/353
1SFN095703R1000 PN460-41
5/353
1SFN095705R1000 PN460-11
5/353
1SFN096100R1000 PR750-1
5/354
1SFN096100R1001 PR750-2
5/354
Order code
Type
Page
1SFN096100R1002 PR580-2
5/354
1SFN096101R1000 PN750-21
5/353
1SFN096103R1000 PN750-41
5/353
1SFN096105R1000 PN750-11
5/353
1SFN124203R1000 LT140-30L
5/93
1SFN124203R2000 LT140-40L
5/191
1SFN124801R1000 LT205-30C
5/93
1SFN124801R2000 LT205-40C
5/191
1SFN124803R1000 LT205-30L
5/93
1SFN124803R2000 LT205-40L
5/191
1SFN124804R1000 LT205-30Y
5/93
1SFN125401R1000 LT370-30C
5/93
1SFN125401R2000 LT370-40C
5/191
1SFN125403R1000 LT370-30L
5/93
1SFN125403R2000 LT370-40L
5/191
1SFN125404R1000 LT370-30Y
5/93
1SFN125406R1000 LT370-30D
5/93
1SFN125701R1000 LT460-AC
5/103
1SFN125703R1000 LT460-AL
5/103
1SFN126101R1000 LT750-AC
5/103
1SFN126103R1000 LT750-AL
5/103
1SFN154310R8006 ZA110
5/380
1SFN154310R8106 ZA110
5/380
1SFN154310R8306 ZA110
5/380
1SFN154310R8406 ZA110
5/380
1SFN154310R8506 ZA110
5/380
1SFN154310R8606 ZA110
5/380
1SFN154310R8806 ZA110
5/380
1SFN155770R6806 ZAF460
5/355
1SFN155770R6906 ZAF460
5/355
1SFN155770R7006 ZAF460
5/355
1SFN155770R7106 ZAF460
5/355
1SFN156170R6806 ZAF750
5/355
1SFN156170R6906 ZAF750
5/355
1SFN156170R7006 ZAF750
5/355
1SFN156170R7106 ZAF750
5/355
1SFN156570R7026 ZAF1650
5/355
1SFN156670R7026 ZAF2650
5/355
1SFN164302R1000 ZLU95
5/380
1SFN164502R1000 ZLU110
5/380
1SFN165703R1000 ZL400
5/355
1SFN165710R1000 ZW460
5/355
1SFN165903R1000 ZL460
5/355
1SFN166103R1000 ZL580
5/355
1SFN166110R1000 ZW750
5/355
1SFN166303R1000 ZL750
5/355
1SFN166403R1000 ZL1250
5/355
1SFN166503R1000 ZL1350
5/355
1SFN166510R1000 ZW1650
5/355
1SFN166521R1070 ZP1650
5/355
1SFN166603R1000 ZL2650
5/355
1SFN166610R1000 ZW2650
5/355
1SFN166621R1070 ZP2650
5/355
1SFN166703R1000 ZL1650
5/355
1SFN167003R1000 ZL2050
5/355
1SNA235156R2700 BA4
4/82
1SNA235712R2400 HTP500-BA4
4/82
1SNA360010R1500
SPRC 1
4/82
2CCS801901R0539 S801S-SCL32-SR 11/2
2CCS801901R0599 S801S-SCL63-SR 11/2
2CCS801901R0639 S801S-SCL100-SR 11/2
2CCS802901R0539 S802S-SCL32-SR 11/2
2CCS802901R0599 S802S-SCL63-SR 11/2
2CCS802901R0639 S802S-SCL100-SR 11/2
2CCS803901R0539 S803S-SCL32-SR 11/2
2CCS803901R0599 S803S-SCL63-SR 11/2
2CCS803901R0639 S803S-SCL100-SR 11/2
2CCS803917R0539 S803W-SCL32-SR 11/2
2CCS803917R0599 S803W-SCL63-SR 11/2
2CCS803917R0639 S803W-SCL100-SR 11/2
FPTN372726R1001 WB75-A
5/342
FPTN372726R1002 WB75-A
5/342
FPTN372726R1003 WB75-A
5/342
FPTN372726R1004 WB75-A
5/342
FPTN372726R1005 WB75-A
5/342
FPTN372726R1006 WB75-A
5/342
FPTN372726R1007 WB75-A
5/342
FPTN372726R1008 WB75-A
5/342
GHV2501902R0002 RV-BC6/60
3/39
GHV2501902R0003 RV-BC6-F/60
3/39
GHV2501903R0002 RV-BC6/250
3/39
GHV2501903R0003 RV-BC6-F/250
3/39
GHV2501904R0002 RV-BC6/380
3/39
GHV2501904R0003 RV-BC6-F/380
3/39
GJF1101903R0001 SA1
2/20
GJF1101903R0002 SA2
2/20
GJF1101903R0003 SA3
2/20
GJH1211001R0221 K6-22Z-01
3/15
GJH1211001R0222 K6-22Z-02
3/15
GJH1211001R0223 K6-22Z-03
3/15
Order code
Type
Page
GJH1211001R0311 K6-31Z-01
GJH1211001R0312 K6-31Z-02
GJH1211001R0313 K6-31Z-03
GJH1211001R0401 K6-40E-01
GJH1211001R0402 K6-40E-02
GJH1211001R0403 K6-40E-03
GJH1211001R8220 K6-22Z-80
GJH1211001R8224 K6-22Z-84
GJH1211001R8225 K6-22Z-85
GJH1211001R8310 K6-31Z-80
GJH1211001R8314 K6-31Z-84
GJH1211001R8315 K6-31Z-85
GJH1211001R8400 K6-40E-80
GJH1211001R8404 K6-40E-84
GJH1211001R8405 K6-40E-85
GJH1211003R0221 K6-22Z-F-01
GJH1211003R0222 K6-22Z-F-02
GJH1211003R0223 K6-22Z-F-03
GJH1211003R0311 K6-31Z-F-01
GJH1211003R0312 K6-31Z-F-02
GJH1211003R0313 K6-31Z-F-03
GJH1211003R0401 K6-40E-F-01
GJH1211003R0402 K6-40E-F-02
GJH1211003R0403 K6-40E-F-03
GJH1211003R8220 K6-22Z-F-80
GJH1211003R8224 K6-22Z-F-84
GJH1211003R8225 K6-22Z-F-85
GJH1211003R8310 K6-31Z-F-80
GJH1211003R8314 K6-31Z-F-84
GJH1211003R8315 K6-31Z-F-85
GJH1211003R8400 K6-40E-F-80
GJH1211003R8404 K6-40E-F-84
GJH1211003R8405 K6-40E-F-85
GJH1211009R0221 K6-22Z-P-01
GJH1211009R0222 K6-22Z-P-02
GJH1211009R0223 K6-22Z-P-03
GJH1211009R0311 K6-31Z-P-01
GJH1211009R0312 K6-31Z-P-02
GJH1211009R0313 K6-31Z-P-03
GJH1211009R0401 K6-40E-P-01
GJH1211009R0402 K6-40E-P-02
GJH1211009R0403 K6-40E-P-03
GJH1211009R8220 K6-22Z-P-80
GJH1211009R8224 K6-22Z-P-84
GJH1211009R8225 K6-22Z-P-85
GJH1211009R8310 K6-31Z-P-80
GJH1211009R8314 K6-31Z-P-84
GJH1211009R8315 K6-31Z-P-85
GJH1211009R8400 K6-40E-P-80
GJH1211009R8404 K6-40E-P-84
GJH1211009R8405 K6-40E-P-85
GJH1213001R0221 KC6-22Z-01
GJH1213001R0223 KC6-22Z-03
GJH1213001R0224 KC6-22Z-04
GJH1213001R0225 KC6-22Z-05
GJH1213001R0227 KC6-22Z-07
GJH1213001R0311 KC6-31Z-01
GJH1213001R0313 KC6-31Z-03
GJH1213001R0314 KC6-31Z-04
GJH1213001R0315 KC6-31Z-05
GJH1213001R0317 KC6-31Z-07
GJH1213001R0401 KC6-40E-01
GJH1213001R0403 KC6-40E-03
GJH1213001R0404 KC6-40E-04
GJH1213001R0405 KC6-40E-05
GJH1213001R0407 KC6-40E-07
GJH1213001R1226 KC6-22Z-16
GJH1213001R1316 KC6-31Z-16
GJH1213001R1406 KC6-40E-16
GJH1213001R5311 KC6-31Z-2.4-51
GJH1213001R5401 KC6-40E-2.4-51
GJH1213001R7221 K6S-22Z-1.7-71
GJH1213001R7222 K6S-22Z-2.8-72
GJH1213001R7311 K6S-31Z-1.7-71
GJH1213001R7312 K6S-31Z-2.8-72
GJH1213001R7401 K6S-40E-1.7-71
GJH1213001R7402 K6S-40E-2.8-72
GJH1213001R8311 KC6-31Z-1.4-81
GJH1213001R8401 KC6-40E-1.4-81
GJH1213003R0221 KC6-22Z-F-01
GJH1213003R0224 KC6-22Z-F-04
GJH1213003R0225 KC6-22Z-F-05
GJH1213003R0227 KC6-22Z-F-07
GJH1213003R0311 KC6-31Z-F-01
GJH1213003R0314 KC6-31Z-F-04
GJH1213003R0315 KC6-31Z-F-05
GJH1213003R0317 KC6-31Z-F-07
GJH1213003R0401 KC6-40E-F-01
GJH1213003R0404 KC6-40E-F-04
GJH1213003R0405 KC6-40E-F-05
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/15
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/36
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/25
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/17
3/17
3/17
3/17
3/17
3/17
3/17
3/17
3/17
3/17
3/37
3/37
3/37
3/37
3/37
3/37
3/37
3/37
3/37
3/37
3/37
ABB | 13/7
13
Index
Order code
Index
Order code classification
13
Type
GJH1213003R1226 KC6-22Z-F-16
GJH1213003R1316 KC6-31Z-F-16
GJH1213003R1406 KC6-40E-F-16
GJH1213003R5311 KC6-31Z-F-51
GJH1213003R5401 KC6-40E-F-51
GJH1213003R8311 KC6-31Z-F-1.4-81
GJH1213003R8401 KC6-40E-F-1.4-81
GJH1213009R0221 KC6-22Z-P-01
GJH1213009R0224 KC6-22Z-P-04
GJH1213009R0225 KC6-22Z-P-05
GJH1213009R0227 KC6-22Z-P-07
GJH1213009R0311 KC6-31Z-P-01
GJH1213009R0314 KC6-31Z-P-04
GJH1213009R0315 KC6-31Z-P-05
GJH1213009R0401 KC6-40E-P-01
GJH1213009R0404 KC6-40E-P-04
GJH1213009R0405 KC6-40E-P-05
GJH1213009R0407 KC6-40E-P-07
GJH1213009R1226 KC6-22Z-P-16
GJH1213009R1316 KC6-31Z-P-16
GJH1213009R1406 KC6-40E-P-16
GJH1213009R5311 KC6-31Z-P-2.4-51
GJH1213009R5401 KC6-40E-P-2.4-51
GJH1213009R8311 KC6-31Z-P-1.4-81
GJH1213009R8401 KC6-40E-P-1.4-81
GJH1213061R5221 TKC6-22Z-51
GJH1213061R5225 TKC6-22Z-55
GJH1213061R5311 TKC6-31Z-51
GJH1213061R5315 TKC6-31Z-55
GJH1213061R5401 TKC6-40E-51
GJH1213061R5405 TKC6-40E-55
GJH1213061R6222 TKC6-22Z-62
GJH1213061R6228 TKC6-22Z-68
GJH1213061R6312 TKC6-31Z-62
GJH1213061R6318 TKC6-31Z-68
GJH1213061R6402 TKC6-40E-62
GJH1213061R6408 TKC6-40E-68
GJL1201317R0001 CA6-11K
GJL1201317R0002 CA6-11E
GJL1201317R0003 CA6-11M
GJL1201317R0004 CA6-11N
GJL1201318R0001 CA6-11K-F
GJL1201318R0002 CA6-11E-F
GJL1201318R0003 CA6-11M-F
GJL1201318R0004 CA6-11N-F
GJL1201319R0001 CA6-11K-P
GJL1201319R0002 CA6-11E-P
GJL1201319R0003 CA6-11M-P
GJL1201319R0004 CA6-11N-P
GJL1201330R0001 CAF6-11K
GJL1201330R0002 CAF6-11E
GJL1201330R0003 CAF6-11M
GJL1201330R0004 CAF6-11N
GJL1201330R0005 CAF6-20K
GJL1201330R0006 CAF6-20E
GJL1201330R0007 CAF6-20M
GJL1201330R0008 CAF6-20N
GJL1201330R0009 CAF6-02K
GJL1201330R0010 CAF6-02E
GJL1201330R0011 CAF6-02M
GJL1201330R0012 CAF6-02N
GJL1201902R0001 LB6
GJL1201903R0001 LB6-CA
GJL1201906R0001 LT6-B
GJL1201907R0001 LP6
GJL1201908R0001 BSM6-30
GJL1211001R0011 B6-30-01-01
GJL1211001R0012 B6-30-01-02
GJL1211001R0013 B6-30-01-03
GJL1211001R0101 B6-30-10-01
GJL1211001R0102 B6-30-10-02
GJL1211001R0103 B6-30-10-03
GJL1211001R8010 B6-30-01-80
GJL1211001R8014 B6-30-01-84
GJL1211001R8015 B6-30-01-85
GJL1211001R8100 B6-30-10-80
GJL1211001R8104 B6-30-10-84
GJL1211001R8105 B6-30-10-85
GJL1211003R0011 B6-30-01-F-01
GJL1211003R0012 B6-30-01-F-02
GJL1211003R0013 B6-30-01-F-03
GJL1211003R0101 B6-30-10-F-01
GJL1211003R0102 B6-30-10-F-02
GJL1211003R0103 B6-30-10-F-03
GJL1211003R8010 B6-30-01-F-80
GJL1211003R8014 B6-30-01-F-84
GJL1211003R8015 B6-30-01-F-85
GJL1211003R8100 B6-30-10-F-80
GJL1211003R8104 B6-30-10-F-84
GJL1211003R8105 B6-30-10-F-85
13/8 | ABB
Page
Order code
3/37
3/37
3/37
3/38
3/38
3/38
3/38
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/26
3/28
3/28
3/28
3/28
3/18
3/18
3/18
3/18
3/18
3/18
3/18
3/18
3/18
3/18
3/18
3/18
3/40
3/39
3/39
3/39
3/40
3/39
3/39
3/39
3/40
3/39
3/39
3/39
3/40
3/39
3/39
3/39
3/40
3/39
3/39
3/39
3/40
3/39
3/39
3/39
3/39
3/39
3/39
3/39
3/39
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
GJL1211009R0011 B6-30-01-P-01
GJL1211009R0012 B6-30-01-P-02
GJL1211009R0013 B6-30-01-P-03
GJL1211009R0101 B6-30-10-P-01
GJL1211009R0102 B6-30-10-P-02
GJL1211009R0103 B6-30-10-P-03
GJL1211009R8010 B6-30-01-P-80
GJL1211009R8014 B6-30-01-P-84
GJL1211009R8015 B6-30-01-P-85
GJL1211009R8100 B6-30-10-P-80
GJL1211009R8104 B6-30-10-P-84
GJL1211009R8105 B6-30-10-P-85
GJL1211201R0001 B6-40-00-01
GJL1211201R0002 B6-40-00-02
GJL1211201R0003 B6-40-00-03
GJL1211201R8000 B6-40-00-80
GJL1211201R8004 B6-40-00-84
GJL1211501R0001 B6-22-00-01
GJL1211501R0002 B6-22-00-02
GJL1211501R0003 B6-22-00-03
GJL1211501R8000 B6-22-00-80
GJL1211501R8004 B6-22-00-84
GJL1211901R0011 VB6-30-01-01
GJL1211901R0012 VB6-30-01-02
GJL1211901R0013 VB6-30-01-03
GJL1211901R0101 VB6-30-10-01
GJL1211901R0102 VB6-30-10-02
GJL1211901R0103 VB6-30-10-03
GJL1211901R8010 VB6-30-01-80
GJL1211901R8014 VB6-30-01-84
GJL1211901R8015 VB6-30-01-85
GJL1211901R8100 VB6-30-10-80
GJL1211901R8104 VB6-30-10-84
GJL1211901R8105 VB6-30-10-85
GJL1211909R0011 VB6-30-01-P-01
GJL1211909R0012 VB6-30-01-P-02
GJL1211909R0013 VB6-30-01-P-03
GJL1211909R0101 VB6-30-10-P-01
GJL1211909R0102 VB6-30-10-P-02
GJL1211909R0103 VB6-30-10-P-03
GJL1211909R8010 VB6-30-01-P-80
GJL1211909R8014 VB6-30-01-P-84
GJL1211909R8015 VB6-30-01-P-85
GJL1211909R8100 VB6-30-10-P-80
GJL1211909R8104 VB6-30-10-P-84
GJL1211909R8105 VB6-30-10-P-85
GJL1211911R0011 VB6A-30-01-01
GJL1211911R0012 VB6A-30-01-02
GJL1211911R0013 VB6A-30-01-03
GJL1211911R0101 VB6A-30-10-01
GJL1211911R0102 VB6A-30-10-02
GJL1211911R0103 VB6A-30-10-03
GJL1211911R8010 VB6A-30-01-80
GJL1211911R8014 VB6A-30-01-84
GJL1211911R8015 VB6A-30-01-85
GJL1211911R8100 VB6A-30-10-80
GJL1211911R8104 VB6A-30-10-84
GJL1211911R8105 VB6A-30-10-85
GJL1211919R0011 VB6A-30-01-P-01
GJL1211919R0012 VB6A-30-01-P-02
GJL1211919R0013 VB6A-30-01-P-03
GJL1211919R0101 VB6A-30-10-P-01
GJL1211919R0102 VB6A-30-10-P-02
GJL1211919R0103 VB6A-30-10-P-03
GJL1211919R8010 VB6A-30-01-P-80
GJL1211919R8014 VB6A-30-01-P-84
GJL1211919R8015 VB6A-30-01-P-85
GJL1211919R8100 VB6A-30-10-P-80
GJL1211919R8104 VB6A-30-10-P-84
GJL1211919R8105 VB6A-30-10-P-85
GJL1213001R0011 BC6-30-01-01
GJL1213001R0013 BC6-30-01-03
GJL1213001R0014 BC6-30-01-04
GJL1213001R0015 BC6-30-01-05
GJL1213001R0017 BC6-30-01-07
GJL1213001R0101 BC6-30-10-01
GJL1213001R0103 BC6-30-10-03
GJL1213001R0104 BC6-30-10-04
GJL1213001R0105 BC6-30-10-05
GJL1213001R0107 BC6-30-10-07
GJL1213001R1016 BC6-30-01-16
GJL1213001R1106 BC6-30-10-16
GJL1213001R5011 BC6-30-01-2.4-51
GJL1213001R5101 BC6-30-10-2.4-51
GJL1213001R7011 B6S-30-01-1.7-71
GJL1213001R7012 B6S-30-01-2.8-72
GJL1213001R7101 B6S-30-10-1.7-71
GJL1213001R7102 B6S-30-10-2.8-72
GJL1213001R8011 BC6-30-01-1.4-81
GJL1213001R8101 BC6-30-10-1.4-81
Type
Page
Order code
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/23
3/23
3/23
3/23
3/23
3/23
3/23
3/23
3/23
3/23
3/23
3/23
3/5
3/5
3/5
3/5
3/5
3/5
3/5
3/5
3/5
3/5
3/5
3/5
3/10
3/10
3/10
3/10
3/10
3/10
3/10
3/10
GJL1213003R0011 BC6-30-01-F-01 3/30
GJL1213003R0013 BC6-30-01-F-03 3/30
GJL1213003R0014 BC6-30-01-F-04 3/30
GJL1213003R0015 BC6-30-01-F-05 3/30
GJL1213003R0017 BC6-30-01-F-07 3/30
GJL1213003R0101 BC6-30-10-F-01 3/30
GJL1213003R0103 BC6-30-10-F-03 3/30
GJL1213003R0104 BC6-30-10-F-04 3/30
GJL1213003R0105 BC6-30-10-F-05 3/30
GJL1213003R0107 BC6-30-10-F-07 3/30
GJL1213003R1016 BC6-30-01-F-16 3/30
GJL1213003R1106 BC6-30-10-F-16 3/30
GJL1213003R5011 BC6-30-01-F-2.4-51
3/35
GJL1213003R5101 BC6-30-10-F-2.4-51
3/35
GJL1213003R8011 BC6-30-01-F-1.4-81
3/35
GJL1213003R8101 BC6-30-10-F-1.4-81
3/35
GJL1213009R0011 BC6-30-01-P-01 3/20
GJL1213009R0013 BC6-30-01-P-03 3/20
GJL1213009R0014 BC6-30-01-P-04 3/20
GJL1213009R0015 BC6-30-01-P-05 3/20
GJL1213009R0017 BC6-30-01-P-07 3/20
GJL1213009R0101 BC6-30-10-P-01 3/20
GJL1213009R0103 BC6-30-10-P-03 3/20
GJL1213009R0104 BC6-30-10-P-04 3/20
GJL1213009R0105 BC6-30-10-P-05 3/20
GJL1213009R0107 BC6-30-10-P-07 3/20
GJL1213009R1016 BC6-30-01-P-16 3/20
GJL1213009R1106 BC6-30-10-P-16 3/20
GJL1213009R5011 BC6-30-01-P-2.4-51
3/27
GJL1213009R5101 BC6-30-10-P-2.4-51
3/27
GJL1213009R8011 BC6-30-01-P-1.4-81
3/27
GJL1213009R8101 BC6-30-10-P-1.4-81
3/27
GJL1213109R0101 BC6-21-10-P-01 3/20
GJL1213109R0103 BC6-21-10-P-03 3/20
GJL1213109R0104 BC6-21-10-P-04 3/20
GJL1213109R0105 BC6-21-10-P-05 3/20
GJL1213109R1106 BC6-21-10-P-16 3/20
GJL1213501R0001 BC6-22-00-01
3/13
GJL1213501R0002 BC6-22-00-02
3/13
GJL1213501R0003 BC6-22-00-03
3/13
GJL1213501R0004 BC6-22-00-04
3/13
GJL1213501R0005 BC6-22-00-05
3/13
GJL1213501R0007 BC6-22-00-07
3/13
GJL1213501R1006 BC6-22-00-16
3/13
GJL1213901R0011 VBC6-30-01-01
3/7
GJL1213901R0013 VBC6-30-01-03
3/7
GJL1213901R0014 VBC6-30-01-04
3/7
GJL1213901R0015 VBC6-30-01-05
3/7
GJL1213901R0017 VBC6-30-01-07
3/7
GJL1213901R0101 VBC6-30-10-01
3/7
GJL1213901R0103 VBC6-30-10-03
3/7
GJL1213901R0104 VBC6-30-10-04
3/7
GJL1213901R0105 VBC6-30-10-05
3/7
GJL1213901R0107 VBC6-30-10-07
3/7
GJL1213901R1016 VBC6-30-01-16
3/7
GJL1213901R1106 VBC6-30-10-16
3/7
GJL1213909R0011 VBC6-30-01-P-01 3/22
GJL1213909R0013 VBC6-30-01-P-03 3/22
GJL1213909R0014 VBC6-30-01-P-04 3/22
GJL1213909R0015 VBC6-30-01-P-05 3/22
GJL1213909R0016 VBC6-30-06-P-06 3/22
GJL1213909R0017 VBC6-30-01-P-07 3/22
GJL1213909R0101 VBC6-30-10-P-01 3/22
GJL1213909R0103 VBC6-30-10-P-03 3/22
GJL1213909R0104 VBC6-30-10-P-04 3/22
GJL1213909R0105 VBC6-30-10-P-05 3/22
GJL1213909R0106 VBC6-30-10-P-06 3/22
GJL1213909R0107 VBC6-30-10-P-07 3/22
GJL1213911R0011 VBC6A-30-01-01 3/9
GJL1213911R0013 VBC6A-30-01-03 3/9
GJL1213911R0014 VBC6A-30-01-04 3/9
GJL1213911R0015 VBC6A-30-01-05 3/9
GJL1213911R0017 VBC6A-30-01-07 3/9
GJL1213911R0101 VBC6A-30-10-01 3/9
GJL1213911R0103 VBC6A-30-10-03 3/9
GJL1213911R0104 VBC6A-30-10-04 3/9
GJL1213911R0105 VBC6A-30-10-05 3/9
GJL1213911R0107 VBC6A-30-10-07 3/9
GJL1213911R1016 VBC6A-30-01-16 3/9
GJL1213911R1106 VBC6A-30-10-16 3/9
GJL1311001R0011 B7-30-01-01
3/4
GJL1311001R0012 B7-30-01-02
3/4
GJL1311001R0013 B7-30-01-03
3/4
GJL1311001R0101 B7-30-10-01
3/4
GJL1311001R0102 B7-30-10-02
3/4
GJL1311001R0103 B7-30-10-03
3/4
GJL1311001R8010 B7-30-01-80
3/4
GJL1311001R8014 B7-30-01-84
3/4
GJL1311001R8015 B7-30-01-85
3/4
GJL1311001R8100 B7-30-10-80
3/4
Type
Page
Index
Order code
Index
Order code classification
Type
GJL1311001R8104 B7-30-10-84
GJL1311001R8105 B7-30-10-85
GJL1311003R0011 B7-30-01-F-01
GJL1311003R0012 B7-30-01-F-02
GJL1311003R0013 B7-30-01-F-03
GJL1311003R0101 B7-30-10-F-01
GJL1311003R0102 B7-30-10-F-02
GJL1311003R0103 B7-30-10-F-03
GJL1311003R8010 B7-30-01-F-80
GJL1311003R8014 B7-30-01-F-84
GJL1311003R8015 B7-30-01-F-85
GJL1311003R8100 B7-30-10-F-80
GJL1311003R8104 B7-30-10-F-84
GJL1311003R8105 B7-30-10-F-85
GJL1311009R0011 B7-30-01-P-01
GJL1311009R0012 B7-30-01-P-02
GJL1311009R0013 B7-30-01-P-03
GJL1311009R0101 B7-30-10-P-01
GJL1311009R0102 B7-30-10-P-02
GJL1311009R0103 B7-30-10-P-03
GJL1311009R8010 B7-30-01-P-80
GJL1311009R8014 B7-30-01-P-84
GJL1311009R8015 B7-30-01-P-85
GJL1311009R8100 B7-30-10-P-80
GJL1311009R8104 B7-30-10-P-84
GJL1311009R8105 B7-30-10-P-85
GJL1311201R0001 B7-40-00-01
GJL1311201R0002 B7-40-00-02
GJL1311201R0003 B7-40-00-03
GJL1311201R8000 B7-40-00-80
GJL1311201R8004 B7-40-00-84
GJL1311501R0001 B7-22-00-01
GJL1311501R0002 B7-22-00-02
GJL1311501R0003 B7-22-00-03
GJL1311501R8000 B7-22-00-80
GJL1311501R8004 B7-22-00-84
GJL1311901R0011 VB7-30-01-01
GJL1311901R0012 VB7-30-01-02
GJL1311901R0013 VB7-30-01-03
GJL1311901R0101 VB7-30-10-01
GJL1311901R0102 VB7-30-10-02
GJL1311901R0103 VB7-30-10-03
GJL1311901R8010 VB7-30-01-80
GJL1311901R8014 VB7-30-01-84
GJL1311901R8015 VB7-30-01-85
GJL1311901R8100 VB7-30-10-80
GJL1311901R8104 VB7-30-10-84
GJL1311901R8105 VB7-30-10-85
GJL1311903R0011 VB7-30-01-F-01
GJL1311903R0012 VB7-30-01-F-02
GJL1311903R0013 VB7-30-01-F-03
GJL1311903R0101 VB7-30-10-F-01
GJL1311903R0102 VB7-30-10-F-02
GJL1311903R0103 VB7-30-10-F-03
GJL1311903R8010 VB7-30-01-F-80
GJL1311903R8014 VB7-30-01-F-84
GJL1311903R8015 VB7-30-01-F-85
GJL1311903R8100 VB7-30-10-F-80
GJL1311903R8104 VB7-30-10-F-84
GJL1311903R8105 VB7-30-10-F-85
GJL1311909R0011 VB7-30-01-P-01
GJL1311909R0012 VB7-30-01-P-02
GJL1311909R0013 VB7-30-01-P-03
GJL1311909R0101 VB7-30-10-P-01
GJL1311909R0102 VB7-30-10-P-02
GJL1311909R0103 VB7-30-10-P-03
GJL1311909R8010 VB7-30-01-P-80
GJL1311909R8014 VB7-30-01-P-84
GJL1311909R8015 VB7-30-01-P-85
GJL1311909R8100 VB7-30-10-P-80
GJL1311909R8104 VB7-30-10-P-84
GJL1311909R8105 VB7-30-10-P-85
GJL1311911R0011 VB7A-30-01-01
GJL1311911R0012 VB7A-30-01-02
GJL1311911R0013 VB7A-30-01-03
GJL1311911R0101 VB7A-30-10-01
GJL1311911R0102 VB7A-30-10-02
GJL1311911R0103 VB7A-30-10-03
GJL1311911R8010 VB7A-30-01-80
GJL1311911R8014 VB7A-30-01-84
GJL1311911R8015 VB7A-30-01-85
GJL1311911R8100 VB7A-30-10-80
GJL1311911R8104 VB7A-30-10-84
GJL1311911R8105 VB7A-30-10-85
GJL1311913R0011 VB7A-30-01-F-01
GJL1311913R0012 VB7A-30-01-F-02
GJL1311913R0013 VB7A-30-01-F-03
GJL1311913R0101 VB7A-30-10-F-01
GJL1311913R0102 VB7A-30-10-F-02
GJL1311913R0103 VB7A-30-10-F-03
Page
Order code
3/4
3/4
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/29
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/19
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/12
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/6
3/31
3/31
3/31
3/31
3/31
3/31
3/31
3/31
3/31
3/31
3/31
3/31
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/21
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/33
3/33
3/33
3/33
3/33
3/33
GJL1311913R8010 VB7A-30-01-F-80 3/33
GJL1311913R8014 VB7A-30-01-F-84 3/33
GJL1311913R8015 VB7A-30-01-F-85 3/33
GJL1311913R8100 VB7A-30-10-F-80 3/33
GJL1311913R8104 VB7A-30-10-F-84 3/33
GJL1311913R8105 VB7A-30-10-F-85 3/33
GJL1311919R0011 VB7A-30-01-P-01 3/23
GJL1311919R0012 VB7A-30-01-P-02 3/23
GJL1311919R0013 VB7A-30-01-P-03 3/23
GJL1311919R0101 VB7A-30-10-P-01 3/23
GJL1311919R0102 VB7A-30-10-P-02 3/23
GJL1311919R0103 VB7A-30-10-P-03 3/23
GJL1311919R8010 VB7A-30-01-P-80 3/23
GJL1311919R8014 VB7A-30-01-P-84 3/23
GJL1311919R8015 VB7A-30-01-P-85 3/23
GJL1311919R8100 VB7A-30-10-P-80 3/23
GJL1311919R8104 VB7A-30-10-P-84 3/23
GJL1311919R8105 VB7A-30-10-P-85 3/23
GJL1313001R0011 BC7-30-01-01
3/5
GJL1313001R0013 BC7-30-01-03
3/5
GJL1313001R0014 BC7-30-01-04
3/5
GJL1313001R0015 BC7-30-01-05
3/5
GJL1313001R0017 BC7-30-01-07
3/5
GJL1313001R0101 BC7-30-10-01
3/5
GJL1313001R0104 BC7-30-10-04
3/5
GJL1313001R0105 BC7-30-10-05
3/5
GJL1313001R0107 BC7-30-10-07
3/5
GJL1313001R1016 BC7-30-01-16
3/5
GJL1313001R1103 BC7-30-10-03
3/5
GJL1313001R1106 BC7-30-10-16
3/5
GJL1313001R5011 BC7-30-01-2.4-51 3/10
GJL1313001R5101 BC7-30-10-2.4-51 3/10
GJL1313001R7011 B7S-30-01-1.7-71 3/10
GJL1313001R7012 B7S-30-01-2.8-72 3/10
GJL1313001R7101 B7S-30-10-1.7-71 3/10
GJL1313001R7102 B7S-30-10-2.8-72 3/10
GJL1313001R8011 BC7-30-01-1.4-81 3/10
GJL1313001R8101 BC7-30-10-1.4-81 3/10
GJL1313003R0011 BC7-30-01-F-01 3/30
GJL1313003R0013 BC7-30-01-F-03 3/30
GJL1313003R0014 BC7-30-01-F-04 3/30
GJL1313003R0015 BC7-30-01-F-05 3/30
GJL1313003R0017 BC7-30-01-F-07 3/30
GJL1313003R0101 BC7-30-10-F-01 3/30
GJL1313003R0103 BC7-30-10-F-03 3/30
GJL1313003R0104 BC7-30-10-F-04 3/30
GJL1313003R0105 BC7-30-10-F-05 3/30
GJL1313003R0107 BC7-30-10-F-07 3/30
GJL1313003R1016 BC7-30-01-F-16 3/30
GJL1313003R1106 BC7-30-10-F-16 3/30
GJL1313003R5011 BC7-30-01-F-2.4-51
3/35
GJL1313003R5101 BC7-30-10-F-2.4-51
3/35
GJL1313003R8011 BC7-30-01-F-1.4-81
3/35
GJL1313003R8101 BC7-30-10-F-1.4-81
3/35
GJL1313009R0011 BC7-30-01-P-01 3/20
GJL1313009R0013 BC7-30-01-P-03 3/20
GJL1313009R0014 BC7-30-01-P-04 3/20
GJL1313009R0015 BC7-30-01-P-05 3/20
GJL1313009R0017 BC7-30-01-P-07 3/20
GJL1313009R0101 BC7-30-10-P-01 3/20
GJL1313009R0103 BC7-30-10-P-03 3/20
GJL1313009R0104 BC7-30-10-P-04 3/20
GJL1313009R0105 BC7-30-10-P-05 3/20
GJL1313009R0107 BC7-30-10-P-07 3/20
GJL1313009R1016 BC7-30-01-P-16 3/20
GJL1313009R1106 BC7-30-10-P-16 3/20
GJL1313009R5011 BC7-30-01-P-2.4-51
3/27
GJL1313009R5101 BC7-30-10-P-2.4-51
3/27
GJL1313009R8011 BC7-30-01-P-1.4-81
3/27
GJL1313009R8101 BC7-30-10-P-1.4-81
3/27
GJL1313061R5011 TBC7-30-01-51
3/11
GJL1313061R5015 TBC7-30-01-55
3/11
GJL1313061R5101 TBC7-30-10-51
3/11
GJL1313061R5105 TBC7-30-10-55
3/11
GJL1313061R6012 TBC7-30-01-62
3/11
GJL1313061R6018 TBC7-30-01-68
3/11
GJL1313061R6102 TBC7-30-10-62
3/11
GJL1313061R6108 TBC7-30-10-68
3/11
GJL1313461R5005 TBC7-31-00-55
3/14
GJL1313461R6002 TBC7-31-00-62
3/14
GJL1313461R6008 TBC7-31-00-68
3/14
GJL1313561R5005 TBC7-22-00-55
3/14
GJL1313561R6002 TBC7-22-00-62
3/14
GJL1313561R6008 TBC7-22-00-68
3/14
GJL1313901R0011 VBC7-30-01-01
3/7
GJL1313901R0013 VBC7-30-01-03
3/7
GJL1313901R0014 VBC7-30-01-04
3/7
GJL1313901R0015 VBC7-30-01-05
3/7
GJL1313901R0017 VBC7-30-01-07
3/7
GJL1313901R0101 VBC7-30-10-01
3/7
Type
Page
Order code
Type
Page
GJL1313901R0103 VBC7-30-10-03
3/7
GJL1313901R0104 VBC7-30-10-04
3/7
GJL1313901R0105 VBC7-30-10-05
3/7
GJL1313901R0107 VBC7-30-10-07
3/7
GJL1313901R1016 VBC7-30-01-16
3/7
GJL1313901R1106 VBC7-30-10-16
3/7
GJL1313903R0011 VBC7-30-01-F-01 3/32
GJL1313903R0013 VBC7-30-01-F-03 3/32
GJL1313903R0014 VBC7-30-01-F-04 3/32
GJL1313903R0015 VBC7-30-01-F-05 3/32
GJL1313903R0017 VBC7-30-01-F-07 3/32
GJL1313903R0101 VBC7-30-10-F-01 3/32
GJL1313903R0103 VBC7-30-10-F-03 3/32
GJL1313903R0104 VBC7-30-10-F-04 3/32
GJL1313903R0105 VBC7-30-10-F-05 3/32
GJL1313903R0107 VBC7-30-10-F-07 3/32
GJL1313903R1016 VBC7-30-01-F-16 3/32
GJL1313903R1106 VBC7-30-10-F-16 3/32
GJL1313909R0011 VBC7-30-01-P-01 3/22
GJL1313909R0013 VBC7-30-01-P-03 3/22
GJL1313909R0014 VBC7-30-01-P-04 3/22
GJL1313909R0015 VBC7-30-01-P-05 3/22
GJL1313909R0017 VBC7-30-01-P-07 3/22
GJL1313909R0101 VBC7-30-10-P-01 3/22
GJL1313909R0103 VBC7-30-10-P-03 3/22
GJL1313909R0104 VBC7-30-10-P-04 3/22
GJL1313909R0105 VBC7-30-10-P-05 3/22
GJL1313909R0107 VBC7-30-10-P-07 3/22
GJL1313909R1016 VBC7-30-01-P-16 3/22
GJL1313909R1106 VBC7-30-10-P-16 3/22
GJL1313911R0011 VBC7A-30-01-01 3/9
GJL1313911R0013 VBC7A-30-01-03 3/9
GJL1313911R0014 VBC7A-30-01-04 3/9
GJL1313911R0015 VBC7A-30-01-05 3/9
GJL1313911R0016 VBC7A-30-01-16 3/9
GJL1313911R0017 VBC7A-30-01-07 3/9
GJL1313911R0101 VBC7A-30-10-01 3/9
GJL1313911R0103 VBC7A-30-10-03 3/9
GJL1313911R0104 VBC7A-30-10-04 3/9
GJL1313911R0105 VBC7A-30-10-05 3/9
GJL1313911R0107 VBC7A-30-10-07 3/9
GJL1313911R1106 VBC7A-30-10-16 3/9
GJL1313913R0011 VBC7A-30-01-F-01 3/34
GJL1313913R0013 VBC7A-30-01-F-03 3/34
GJL1313913R0014 VBC7A-30-01-F-04 3/34
GJL1313913R0015 VBC7A-30-01-F-05 3/34
GJL1313913R0017 VBC7A-30-01-F-07 3/34
GJL1313913R0101 VBC7A-30-10-F-01 3/34
GJL1313913R0103 VBC7A-30-10-F-03 3/34
GJL1313913R0104 VBC7A-30-10-F-04 3/34
GJL1313913R0105 VBC7A-30-10-F-05 3/34
GJL1313913R0107 VBC7A-30-10-F-07 3/34
GJL1313913R1016 VBC7A-30-01-F-16 3/34
GJL1313913R1106 VBC7A-30-10-F-16 3/34
GJL1313919R0011 VBC7A-30-01-P-01 3/24
GJL1313919R0013 VBC7A-30-01-P-03 3/24
GJL1313919R0014 VBC7A-30-01-P-04 3/24
GJL1313919R0015 VBC7A-30-01-P-05 3/24
GJL1313919R0017 VBC7A-30-01-P-07 3/24
GJL1313919R0101 VBC7A-30-10-P-01 3/24
GJL1313919R0103 VBC7A-30-10-P-03 3/24
GJL1313919R0104 VBC7A-30-10-P-04 3/24
GJL1313919R0105 VBC7A-30-10-P-05 3/24
GJL1313919R0107 VBC7A-30-10-P-07 3/24
GJL1313919R1016 VBC7A-30-01-P-16 3/24
GJL1313919R1106 VBC7A-30-10-P-16 3/24
GJL1317001R0011 B7D-30-01-01
3/5
GJL1317001R0015 B7D-30-01-05
3/5
GJL1317001R0101 B7D-30-10-01
3/5
GJL1317001R0105 B7D-30-10-05
3/5
GJL1317201R0001 B7D-40-00-01
3/13
GJL1317201R0005 B7D-40-00-05
3/13
13
Index
Order code
ABB | 13/9
Index
Type classification
Type
Page
Type
Order code
Page
Type
Order code
Page
Index
13
Order code
AA1-110 1SAM201910R1002
2/16
AF116-30-22-13 1SFL427001R1322
5/110
AF140-30-00B-11 1SFL447002R1100
5/88
AA1-230 1SAM201910R1003
2/16
AF116-30-22-14 1SFL427001R1422
5/110
AF140-30-00B-12 1SFL447002R1200
5/88
AA1-24 1SAM201910R1001
2/16
AF116-30-22-33 1SFL427001R3322
5/111
AF140-30-00B-13 1SFL447002R1300
5/88
AA1-400 1SAM201910R1004
2/16
AF116-30-22-34 1SFL427001R3422
5/111
AF140-30-00B-14 1SFL447002R1400
5/88
AA4-110 1SAM401907R1002
2/32
AF116-30-22B-11 1SFL427002R1122
5/110
AF140-30-00B-33 1SFL447002R3300
5/89
AA4-230 1SAM401907R1003
2/32
AF116-30-22B-12 1SFL427002R1222
5/110
AF140-30-00B-34 1SFL447002R3400
5/89
AA4-24 1SAM401907R1001
2/32
AF116-30-22B-13 1SFL427002R1322
5/110
AF140-30-11-11 1SFL447001R1111
5/94
AA4-400 1SAM401907R1004
2/32
AF116-30-22B-14 1SFL427002R1422
5/110
AF140-30-11-12 1SFL447001R1211
5/94
AF09-22-00-12 1SBL137501R1200
5/182
AF116-30-22B-33 1SFL427002R3322
5/111
AF140-30-11-13 1SFL447001R1311
5/94
AF09-22-00-13 1SBL137501R1300
5/182
AF116-30-22B-34 1SFL427002R3422
5/111
AF140-30-11-14 1SFL447001R1411
5/94
AF09-22-00-14 1SBL137501R1400
5/182
AF116-40-00-11 1SFL427101R1100
5/188
AF140-30-11-33 1SFL447001R3311
5/95
AF09-22-00-41 1SBL137501R4100
5/182
AF116-40-00-12 1SFL427101R1200
5/188
AF140-30-11-34 1SFL447001R3411
5/95
AF09-30-01-12 1SBL137001R1201
5/82
AF116-40-00-13 1SFL427101R1300
5/188
AF140-30-11B-11 1SFL447002R1111
5/94
AF09-30-01-13 1SBL137001R1301
5/82
AF116-40-00-14 1SFL427101R1400
5/188
AF140-30-11B-12 1SFL447002R1211
5/94
AF09-30-01-14 1SBL137001R1401
5/82
AF116-40-00B-11 1SFL427102R1100
5/188
AF140-30-11B-13 1SFL447002R1311
5/94
AF09-30-01-41 1SBL137001R4101
5/82
AF116-40-00B-12 1SFL427102R1200
5/188
AF140-30-11B-14 1SFL447002R1411
5/94
AF09-30-01S-12 1SBL137004R1201
6/46
AF116-40-00B-13 1SFL427102R1300
5/188
AF140-30-11B-33 1SFL447002R3311
5/95
AF09-30-01S-13 1SBL137004R1301
6/46
AF116-40-00B-14 1SFL427102R1400
5/188
AF140-30-11B-34 1SFL447002R3411
5/95
AF09-30-01S-14 1SBL137004R1401
6/46
AF116-40-11-11 1SFL427101R1111
5/192
AF140-30-22-11 1SFL447001R1122
5/110
AF09-30-01S-41 1SBL137004R4101
6/46
AF116-40-11-12 1SFL427101R1211
5/192
AF140-30-22-12 1SFL447001R1222
5/110
AF09-30-10-12 1SBL137001R1210
5/82
AF116-40-11-13 1SFL427101R1311
5/192
AF140-30-22-13 1SFL447001R1322
5/110
1SFL447001R1422
5/110
AF09-30-10-13 1SBL137001R1310
5/82
AF116-40-11-14 1SFL427101R1411
5/192
AF140-30-22-33 1SFL447001R3322
5/111
AF09-30-10-14 1SBL137001R1410
5/82
AF116-40-11B-11 1SFL427102R1111
5/192
1SFL447001R3422
5/111
AF09-30-10-41 1SBL137001R4110
5/82
AF116-40-11B-12 1SFL427102R1211
5/192
AF140-30-22B-11 1SFL447002R1122
5/110
AF09-30-10S-12 1SBL137004R1210
6/46
AF116-40-11B-13 1SFL427102R1311
5/192
AF140-30-22B-12 1SFL447002R1222
5/110
AF09-30-10S-13 1SBL137004R1310
6/46
AF116-40-11B-14 1SFL427102R1411
5/192
AF140-30-22B-13 1SFL447002R1322
5/110
AF09-30-10S-14 1SBL137004R1410
6/46
AF116-40-22-11 1SFL427101R1122
5/196
AF140-30-22B-14 1SFL447002R1422
5/110
AF09-30-10S-41 1SBL137004R4110
6/46
AF116-40-22-12 1SFL427101R1222
5/196
AF140-30-22B-33 1SFL447002R3322
5/111
AF09-30-22-12 1SBL137001R1222
5/104
AF116-40-22-13 1SFL427101R1322
5/196
AF140-30-22B-34 1SFL447002R3422
5/111
AF09-30-22-13 1SBL137001R1322
5/104
AF116-40-22-14 1SFL427101R1422
5/196
AF140-40-00-11 1SFL447101R1100
5/188
AF09-30-22-14 1SBL137001R1422
5/104
AF116-40-22B-11 1SFL427102R1122
5/196
AF140-40-00-12 1SFL447101R1200
5/188
AF09-30-22-41 1SBL137001R4122
5/104
AF116-40-22B-12 1SFL427102R1222
5/196
AF140-40-00-13 1SFL447101R1300
5/188
AF09-30-22S-12 1SBL137004R1222
6/48
AF116-40-22B-13 1SFL427102R1322
5/196
AF140-40-00-14 1SFL447101R1400
5/188
AF09-30-22S-13 1SBL137004R1322
6/48
AF116-40-22B-14 1SFL427102R1422
5/196
AF140-40-00B-11 1SFL447102R1100
5/188
AF09-30-22S-14 1SBL137004R1422
6/48
AF12-30-01-12 1SBL157001R1201
5/82
AF140-40-00B-12 1SFL447102R1200
5/188
AF09-30-22S-41 1SBL137004R4122
6/48
AF12-30-01-13 1SBL157001R1301
5/82
AF140-40-00B-13 1SFL447102R1300
5/188
AF09-40-00-12 1SBL137201R1200
5/182
AF12-30-01-14 1SBL157001R1401
5/82
AF140-40-00B-14 1SFL447102R1400
5/188
AF09-40-00-13 1SBL137201R1300
5/182
AF12-30-01-41 1SBL157001R4101
5/82
AF140-40-11-11 1SFL447101R1111
5/192
AF09-40-00-14 1SBL137201R1400
5/182
AF12-30-01S-12 1SBL157004R1201
6/46
AF140-40-11-12 1SFL447101R1211
5/192
AF09-40-00-41 1SBL137201R4100
5/182
AF12-30-01S-13 1SBL157004R1301
6/46
AF140-40-11-13 1SFL447101R1311
5/192
AF09Z-22-00-20 1SBL136501R2000
5/183
AF12-30-01S-14 1SBL157004R1401
6/46
AF140-40-11-14 1SFL447101R1411
5/192
AF09Z-22-00-21 1SBL136501R2100
5/183
AF12-30-01S-41 1SBL157004R4101
6/46
AF140-40-11B-11 1SFL447102R1111
5/192
AF09Z-22-00-22 1SBL136501R2200
5/183
AF12-30-10-12 1SBL157001R1210
5/82
AF140-40-11B-12 1SFL447102R1211
5/192
AF09Z-22-00-23 1SBL136501R2300
5/183
AF12-30-10-13 1SBL157001R1310
5/82
AF140-40-11B-13 1SFL447102R1311
5/192
AF09Z-30-01S-20 1SBL136004R2001
6/47
AF12-30-10-14 1SBL157001R1410
5/82
AF140-40-11B-14 1SFL447102R1411
5/192
AF09Z-30-01S-21 1SBL136004R2101
6/47
AF12-30-10-41 1SBL157001R4110
5/82
AF140-40-22-11 1SFL447101R1122
5/196
AF09Z-30-01S-22 1SBL136004R2201
6/47
AF12-30-10S-12 1SBL157004R1210
6/46
AF140-40-22-12 1SFL447101R1222
5/196
AF09Z-30-01S-23 1SBL136004R2301
6/47
AF12-30-10S-13 1SBL157004R1310
6/46
AF140-40-22-13 1SFL447101R1322
5/196
AF09Z-30-10S-20 1SBL136004R2010
6/47
AF12-30-10S-14 1SBL157004R1410
6/46
AF140-40-22-14 1SFL447101R1422
5/196
AF09Z-30-10S-21 1SBL136004R2110
6/47
AF12-30-10S-41 1SBL157004R4110
6/46
AF140-40-22B-11 1SFL447102R1122
5/196
AF09Z-30-10S-22 1SBL136004R2210
6/47
AF12-30-22-12 1SBL157001R1222
5/104
AF140-40-22B-12 1SFL447102R1222
5/196
AF09Z-30-10S-23 1SBL136004R2310
6/47
AF12-30-22-13 1SBL157001R1322
5/104
AF140-40-22B-13 1SFL447102R1322
5/196
AF09Z-30-22-20 1SBL136001R2022
5/105
AF12-30-22-14 1SBL157001R1422
5/104
AF140-40-22B-14 1SFL447102R1422
5/196
AF09Z-30-22-21 1SBL136001R2122
5/105
AF12-30-22-41 1SBL157001R4122
5/104
AF146-30-00-11 1SFL467001R1100
5/88
AF09Z-30-22-22 1SBL136001R2222
5/105
AF12-30-22S-12 1SBL157004R1222
6/48
AF146-30-00-12 1SFL467001R1200
5/88
AF09Z-30-22-23 1SBL136001R2322
5/105
AF12-30-22S-13 1SBL157004R1322
6/48
AF146-30-00-13 1SFL467001R1300
5/88
AF09Z-30-22S-20 1SBL136004R2022
6/49
AF12-30-22S-14 1SBL157004R1422
6/48
AF146-30-00-14 1SFL467001R1400
5/88
AF09Z-30-22S-21 1SBL136004R2122
6/49
AF12-30-22S-41 1SBL157004R4122
6/48
AF146-30-00-33 1SFL467001R3300
5/89
AF09Z-30-22S-22 1SBL136004R2222
6/49
AF1250-30-11 1SFL647001R6811
5/101
AF146-30-00-34 1SFL467001R3400
5/89
AF09Z-30-22S-23 1SBL136004R2322
6/49
1SFL647001R6911
5/101
AF146-30-00B-11 1SFL467002R1100
5/88
AF09Z-40-00-20 1SBL136201R2000
5/183
1SFL647001R7011
5/101
AF146-30-00B-12 1SFL467002R1200
5/88
AF09Z-40-00-21 1SBL136201R2100
5/183
1SFL647001R7111
5/101
AF146-30-00B-13 1SFL467002R1300
5/88
AF09Z-40-00-22 1SBL136201R2200
5/183
AF1250-30-22 1SFL647001R6822
5/117
AF146-30-00B-14 1SFL467002R1400
5/88
AF09Z-40-00-23 1SBL136201R2300
5/183
1SFL647001R6922
5/117
AF146-30-00B-33 1SFL467002R3300
5/89
AF116-30-00-11 1SFL427001R1100
5/88
1SFL647001R7022
5/117
AF146-30-00B-34 1SFL467002R3400
5/89
AF116-30-00-12 1SFL427001R1200
5/88
1SFL647001R7122
5/117
AF146-30-11-11 1SFL467001R1111
5/94
AF116-30-00-13 1SFL427001R1300
5/88
AF12Z-30-01S-20 1SBL156004R2001
6/47
AF146-30-11-12 1SFL467001R1211
5/94
AF116-30-00-14 1SFL427001R1400
5/88
AF12Z-30-01S-21 1SBL156004R2101
6/47
AF146-30-11-13 1SFL467001R1311
5/94
AF116-30-00-33 1SFL427001R3300
5/89
AF12Z-30-01S-22 1SBL156004R2201
6/47
AF146-30-11-14 1SFL467001R1411
5/94
AF116-30-00-34 1SFL427001R3400
5/89
AF12Z-30-01S-23 1SBL156004R2301
6/47
AF146-30-11-33 1SFL467001R3311
5/95
AF116-30-00B-11 1SFL427002R1100
5/88
AF12Z-30-10S-20 1SBL156004R2010
6/47
AF146-30-11-34 1SFL467001R3411
5/95
AF116-30-00B-12 1SFL427002R1200
5/88
AF12Z-30-10S-21 1SBL156004R2110
6/47
AF146-30-11B-11 1SFL467002R1111
5/94
AF116-30-00B-13 1SFL427002R1300
5/88
AF12Z-30-10S-22 1SBL156004R2210
6/47
AF146-30-11B-12 1SFL467002R1211
5/94
AF116-30-00B-14 1SFL427002R1400
5/88
AF12Z-30-10S-23 1SBL156004R2310
6/47
AF146-30-11B-13 1SFL467002R1311
5/94
AF116-30-00B-33 1SFL427002R3300
5/89
AF12Z-30-22-20 1SBL156001R2022
5/105
AF146-30-11B-14 1SFL467002R1411
5/94
AF116-30-00B-34 1SFL427002R3400
5/89
AF12Z-30-22-21 1SBL156001R2122
5/105
AF146-30-11B-33 1SFL467002R3311
5/95
AF116-30-11-11 1SFL427001R1111
5/94
AF12Z-30-22-22 1SBL156001R2222
5/105
AF146-30-22-11 1SFL467001R1122
5/110
AF116-30-11-12 1SFL427001R1211
5/94
AF12Z-30-22-23 1SBL156001R2322
5/105
AF146-30-22-12 1SFL467001R1222
5/110
AF116-30-11-13 1SFL427001R1311
5/94
AF12Z-30-22S-20 1SBL156004R2022
6/49
AF146-30-22-13 1SFL467001R1322
5/110
AF116-30-11-14 1SFL427001R1411
5/94
AF12Z-30-22S-21 1SBL156004R2122
6/49
AF146-30-22-14 1SFL467001R1422
5/110
AF116-30-11-33 1SFL427001R3311
5/95
AF12Z-30-22S-22 1SBL156004R2222
6/49
AF146-30-22-33 1SFL467001R3322
5/111
AF116-30-11-34 1SFL427001R3411
5/95
AF12Z-30-22S-23 1SBL156004R2322
6/49
AF146-30-22-34 1SFL467001R3422
5/111
AF116-30-11B-11 1SFL427002R1111
5/94
AF1350-30-11 1SFL657001R7011
5/101
AF146-30-22B-11 1SFL467002R1122
5/110
AF116-30-11B-12 1SFL427002R1211
5/94
AF1350-30-22 1SFL657001R7022
5/117
AF146-30-22B-12 1SFL467002R1222
5/110
AF116-30-11B-13 1SFL427002R1311
5/94
AF140-30-00-11 1SFL447001R1100
5/88
AF146-30-22B-13 1SFL467002R1322
5/110
AF116-30-11B-14 1SFL427002R1411
5/94
AF140-30-00-12 1SFL447001R1200
5/88
AF146-30-22B-14 1SFL467002R1422
5/110
AF116-30-11B-33 1SFL427002R3311
5/95
AF140-30-00-13 1SFL447001R1300
5/88
AF146-30-22B-33 1SFL467002R3322
5/111
AF116-30-11B-34 1SFL427002R3411
5/95
AF140-30-00-14 1SFL447001R1400
5/88
AF146-30-22B-34 1SFL467002R3422
5/111
AF116-30-22-11 1SFL427001R1122
5/110
AF140-30-00-33 1SFL447001R3300
5/89
AF16-22-00-12 1SBL177501R1200
5/182
AF116-30-22-12 1SFL427001R1222
5/110
AF140-30-00-34 1SFL447001R3400
5/89
13/10 | ABB
Index
Type classification
Order code
Page
AF16-22-00-13 1SBL177501R1300
5/182
AF16-22-00-14 1SBL177501R1400
5/182
AF16-22-00-41 1SBL177501R4100
5/182
AF16-30-01-12 1SBL177001R1201
5/82
AF16-30-01-13 1SBL177001R1301
5/82
AF16-30-01-14 1SBL177001R1401
5/82
AF16-30-01-41 1SBL177001R4101
5/82
AF16-30-01S-12 1SBL177004R1201
6/46
AF16-30-01S-13 1SBL177004R1301
6/46
AF16-30-01S-14 1SBL177004R1401
6/46
AF16-30-01S-41 1SBL177004R4101
6/46
AF16-30-10-12 1SBL177001R1210
5/82
AF16-30-10-13 1SBL177001R1310
5/82
AF16-30-10-14 1SBL177001R1410
5/82
AF16-30-10-41 1SBL177001R4110
5/82
AF16-30-10S-12 1SBL177004R1210
6/46
AF16-30-10S-13 1SBL177004R1310
6/46
AF16-30-10S-14 1SBL177004R1410
6/46
AF16-30-10S-41 1SBL177004R4110
6/46
AF16-30-22-12 1SBL177001R1222
5/104
AF16-30-22-13 1SBL177001R1322
5/104
AF16-30-22-14 1SBL177001R1422
5/104
AF16-30-22-41 1SBL177001R4122
5/104
AF16-30-22S-12 1SBL177004R1222
6/48
AF16-30-22S-13 1SBL177004R1322
6/48
AF16-30-22S-14 1SBL177004R1422
6/48
AF16-30-22S-41 1SBL177004R4122
6/48
AF16-40-00-12 1SBL177201R1200
5/182
AF16-40-00-13 1SBL177201R1300
5/182
AF16-40-00-14 1SBL177201R1400
5/182
AF16-40-00-41 1SBL177201R4100
5/182
AF1650-30-11 1SFL677001R7011
5/101
AF1650-30-22 1SFL677001R7022
5/117
AF16Z-22-00-20 1SBL176501R2000
5/183
AF16Z-22-00-21 1SBL176501R2100
5/183
AF16Z-22-00-22 1SBL176501R2200
5/183
AF16Z-22-00-23 1SBL176501R2300
5/183
AF16Z-30-01S-20 1SBL176004R2001
6/47
AF16Z-30-01S-21 1SBL176004R2101
6/47
AF16Z-30-01S-22 1SBL176004R2201
6/47
AF16Z-30-01S-23 1SBL176004R2301
6/47
AF16Z-30-10S-20 1SBL176004R2010
6/47
AF16Z-30-10S-21 1SBL176004R2110
6/47
AF16Z-30-10S-22 1SBL176004R2210
6/47
AF16Z-30-10S-23 1SBL176004R2310
6/47
AF16Z-30-22-20 1SBL176001R2022
5/105
AF16Z-30-22-21 1SBL176001R2122
5/105
AF16Z-30-22-22 1SBL176001R2222
5/105
AF16Z-30-22-23 1SBL176001R2322
5/105
AF16Z-30-22S-20 1SBL176004R2022
6/49
AF16Z-30-22S-21 1SBL176004R2122
6/49
AF16Z-30-22S-22 1SBL176004R2222
6/49
AF16Z-30-22S-23 1SBL176004R2322
6/49
AF16Z-40-00-20 1SBL176201R2000
5/183
AF16Z-40-00-21 1SBL176201R2100
5/183
AF16Z-40-00-22 1SBL176201R2200
5/183
AF16Z-40-00-23 1SBL176201R2300
5/183
AF190-30-00-11 1SFL487002R1100
5/90
AF190-30-00-12 1SFL487002R1200
5/90
AF190-30-00-13 1SFL487002R1300
5/90
AF190-30-00-14 1SFL487002R1400
5/90
AF190-30-00-33 1SFL487002R3300
5/91
AF190-30-00-34 1SFL487002R3400
5/91
AF190-30-11-11 1SFL487002R1111
5/96
AF190-30-11-12 1SFL487002R1211
5/96
AF190-30-11-13 1SFL487002R1311
5/96
AF190-30-11-14 1SFL487002R1411
5/96
AF190-30-11-33 1SFL487002R3311
5/97
AF190-30-11-34 1SFL487002R3411
5/97
AF190-30-22-11 1SFL487002R1122
5/112
AF190-30-22-12 1SFL487002R1222
5/112
AF190-30-22-13 1SFL487002R1322
5/112
AF190-30-22-14 1SFL487002R1422
5/112
AF190-30-22-33 1SFL487002R3322
5/113
AF190-30-22-34 1SFL487002R3422
5/113
AF190-40-00-11 1SFL487102R1100
5/189
AF190-40-00-12 1SFL487102R1200
5/189
AF190-40-00-13 1SFL487102R1300
5/189
AF190-40-00-14 1SFL487102R1400
5/189
AF190-40-11-11 1SFL487102R1111
5/193
AF190-40-11-12 1SFL487102R1211
5/193
AF190-40-11-13 1SFL487102R1311
5/193
AF190-40-11-14 1SFL487102R1411
5/193
AF190-40-22-11 1SFL487102R1122
5/197
AF190-40-22-12 1SFL487102R1222
5/197
AF190-40-22-13 1SFL487102R1322
5/197
AF190-40-22-14 1SFL487102R1422
5/197
AF2050-30-11 1SFL707001R7011
5/101
AF2050-30-22 1SFL707001R7022
5/117
AF205-30-00-11 1SFL527002R1100
5/90
Type
Order code
Page
AF205-30-00-12 1SFL527002R1200
5/90
AF205-30-00-13 1SFL527002R1300
5/90
AF205-30-00-14 1SFL527002R1400
5/90
AF205-30-00-33 1SFL527002R3300
5/91
AF205-30-00-34 1SFL527002R3400
5/91
AF205-30-11-11 1SFL527002R1111
5/96
AF205-30-11-12 1SFL527002R1211
5/96
AF205-30-11-13 1SFL527002R1311
5/96
AF205-30-11-14 1SFL527002R1411
5/96
AF205-30-11-33 1SFL527002R3311
5/97
AF205-30-11-34 1SFL527002R3411
5/97
AF205-30-22-11 1SFL527002R1122
5/112
AF205-30-22-12 1SFL527002R1222
5/112
AF205-30-22-13 1SFL527002R1322
5/112
AF205-30-22-14 1SFL527002R1422
5/112
AF205-30-22-33 1SFL527002R3322
5/113
AF205-30-22-34 1SFL527002R3422
5/113
AF205-40-00-11 1SFL527102R1100
5/189
AF205-40-00-12 1SFL527102R1200
5/189
AF205-40-00-13 1SFL527102R1300
5/189
AF205-40-00-14 1SFL527102R1400
5/189
AF205-40-11-11 1SFL527102R1111
5/193
AF205-40-11-12 1SFL527102R1211
5/193
AF205-40-11-13 1SFL527102R1311
5/193
AF205-40-11-14 1SFL527102R1411
5/193
AF205-40-22-11 1SFL527102R1122
5/197
AF205-40-22-12 1SFL527102R1222
5/197
AF205-40-22-13 1SFL527102R1322
5/197
AF205-40-22-14 1SFL527102R1422
5/197
AF26-22-00-12 1SBL237501R1200
5/182
AF26-22-00-13 1SBL237501R1300
5/182
AF26-22-00-14 1SBL237501R1400
5/182
AF26-22-00-41 1SBL237501R4100
5/182
AF26-30-00-12 1SBL237001R1200
5/82
AF26-30-00-13 1SBL237001R1300
5/82
AF26-30-00-14 1SBL237001R1400
5/82
AF26-30-00-41 1SBL237001R4100
5/82
AF26-30-00S-12 1SBL237004R1200
6/46
AF26-30-00S-13 1SBL237004R1300
6/46
AF26-30-00S-14 1SBL237004R1400
6/46
AF26-30-00S-41 1SBL237004R4100
6/46
AF26-30-11-12 1SBL237001R1211
5/104
AF26-30-11-13 1SBL237001R1311
5/104
AF26-30-11-14 1SBL237001R1411
5/104
AF26-30-11-41 1SBL237001R4111
5/104
AF26-30-11S-12 1SBL237004R1211
6/48
AF26-30-11S-13 1SBL237004R1311
6/48
AF26-30-11S-14 1SBL237004R1411
6/48
AF26-30-11S-41 1SBL237004R4111
6/48
AF26-30-22-12 1SBL237001R1222
5/104
AF26-30-22-13 1SBL237001R1322
5/104
AF26-30-22-14 1SBL237001R1422
5/104
AF26-30-22-41 1SBL237001R4122
5/104
AF26-30-22S-12 1SBL237004R1222
6/48
AF26-30-22S-13 1SBL237004R1322
6/48
AF26-30-22S-14 1SBL237004R1422
6/48
AF26-30-22S-41 1SBL237004R4122
6/48
AF26-40-00-12 1SBL237201R1200
5/182
AF26-40-00-13 1SBL237201R1300
5/182
AF26-40-00-14 1SBL237201R1400
5/182
AF26-40-00-41 1SBL237201R4100
5/182
AF2650-30-11 1SFL667001R7011
5/101
AF2650-30-22 1SFL667001R7022
5/117
AF265-30-00-11 1SFL547002R1100
5/90
AF265-30-00-12 1SFL547002R1200
5/90
AF265-30-00-13 1SFL547002R1300
5/90
AF265-30-00-14 1SFL547002R1400
5/90
AF265-30-00-33 1SFL547002R3300
5/91
AF265-30-00-34 1SFL547002R3400
5/91
AF265-30-11-11 1SFL547002R1111
5/96
AF265-30-11-12 1SFL547002R1211
5/96
AF265-30-11-13 1SFL547002R1311
5/96
AF265-30-11-14 1SFL547002R1411
5/96
AF265-30-11-33 1SFL547002R3311
5/97
AF265-30-11-34 1SFL547002R3411
5/97
AF265-30-22-11 1SFL547002R1122
5/112
AF265-30-22-12 1SFL547002R1222
5/112
AF265-30-22-13 1SFL547002R1322
5/112
AF265-30-22-14 1SFL547002R1422
5/112
AF265-30-22-33 1SFL547002R3322
5/113
AF265-30-22-34 1SFL547002R3422
5/113
AF265-40-00-11 1SFL547102R1100
5/189
AF265-40-00-12 1SFL547102R1200
5/189
AF265-40-00-13 1SFL547102R1300
5/189
AF265-40-00-14 1SFL547102R1400
5/189
AF265-40-11-11 1SFL547102R1111
5/193
AF265-40-11-12 1SFL547102R1211
5/193
AF265-40-11-13 1SFL547102R1311
5/193
AF265-40-11-14 1SFL547102R1411
5/193
AF265-40-22-11 1SFL547102R1122
5/197
Type
Order code
Page
AF265-40-22-12 1SFL547102R1222
5/197
AF265-40-22-13 1SFL547102R1322
5/197
AF265-40-22-14 1SFL547102R1422
5/197
AF26Z-22-00-20 1SBL236501R2000
5/183
AF26Z-22-00-21 1SBL236501R2100
5/183
AF26Z-22-00-22 1SBL236501R2200
5/183
AF26Z-22-00-23 1SBL236501R2300
5/183
AF26Z-30-00S-20 1SBL236004R2000
6/47
AF26Z-30-00S-21 1SBL236004R2100
6/47
AF26Z-30-00S-22 1SBL236004R2200
6/47
AF26Z-30-00S-23 1SBL236004R2300
6/47
AF26Z-30-11-20 1SBL236001R2011
5/105
AF26Z-30-11-21 1SBL236001R2111
5/105
AF26Z-30-11-22 1SBL236001R2211
5/105
AF26Z-30-11-23 1SBL236001R2311
5/105
AF26Z-30-11S-20 1SBL236004R2011
6/49
AF26Z-30-11S-21 1SBL236004R2111
6/49
AF26Z-30-11S-22 1SBL236004R2211
6/49
AF26Z-30-11S-23 1SBL236004R2311
6/49
AF26Z-30-22-20 1SBL236001R2022
5/105
AF26Z-30-22-21 1SBL236001R2122
5/105
AF26Z-30-22-22 1SBL236001R2222
5/105
AF26Z-30-22-23 1SBL236001R2322
5/105
AF26Z-30-22S-20 1SBL236004R2022
6/49
AF26Z-30-22S-21 1SBL236004R2122
6/49
AF26Z-30-22S-22 1SBL236004R2222
6/49
AF26Z-30-22S-23 1SBL236004R2322
6/49
AF26Z-40-00-20 1SBL236201R2000
5/183
AF26Z-40-00-21 1SBL236201R2100
5/183
AF26Z-40-00-22 1SBL236201R2200
5/183
AF26Z-40-00-23 1SBL236201R2300
5/183
AF30-30-00-12 1SBL277001R1200
5/82
AF30-30-00-13 1SBL277001R1300
5/82
AF30-30-00-14 1SBL277001R1400
5/82
AF30-30-00-41 1SBL277001R4100
5/82
AF30-30-11-12 1SBL277001R1211
5/104
AF30-30-11-13 1SBL277001R1311
5/104
AF30-30-11-14 1SBL277001R1411
5/104
AF30-30-11-41 1SBL277001R4111
5/104
AF30-30-22-12 1SBL277001R1222
5/104
AF30-30-22-13 1SBL277001R1322
5/104
AF30-30-22-14 1SBL277001R1422
5/104
AF30-30-22-41 1SBL277001R4122
5/104
AF305-30-00-11 1SFL587002R1100
5/90
AF305-30-00-12 1SFL587002R1200
5/90
AF305-30-00-13 1SFL587002R1300
5/90
AF305-30-00-14 1SFL587002R1400
5/90
AF305-30-00-33 1SFL587002R3300
5/91
AF305-30-00-34 1SFL587002R3400
5/91
AF305-30-11-11 1SFL587002R1111
5/96
AF305-30-11-12 1SFL587002R1211
5/96
AF305-30-11-13 1SFL587002R1311
5/96
AF305-30-11-14 1SFL587002R1411
5/96
AF305-30-11-33 1SFL587002R3311
5/97
AF305-30-11-34 1SFL587002R3411
5/97
AF305-30-22-11 1SFL587002R1122
5/112
AF305-30-22-12 1SFL587002R1222
5/112
AF305-30-22-13 1SFL587002R1322
5/112
AF305-30-22-14 1SFL587002R1422
5/112
AF305-30-22-33 1SFL587002R3322
5/113
AF305-30-22-34 1SFL587002R3422
5/113
AF305-40-00-11 1SFL587102R1100
5/189
AF305-40-00-12 1SFL587102R1200
5/189
AF305-40-00-13 1SFL587102R1300
5/189
AF305-40-00-14 1SFL587102R1400
5/189
AF305-40-11-11 1SFL587102R1111
5/193
AF305-40-11-12 1SFL587102R1211
5/193
AF305-40-11-13 1SFL587102R1311
5/193
AF305-40-11-14 1SFL587102R1411
5/193
AF305-40-22-11 1SFL587102R1122
5/197
AF305-40-22-12 1SFL587102R1222
5/197
AF305-40-22-13 1SFL587102R1322
5/197
AF305-40-22-14 1SFL587102R1422
5/197
AF30Z-30-11-20 1SBL276001R2011
5/105
AF30Z-30-11-21 1SBL276001R2111
5/105
AF30Z-30-11-22 1SBL276001R2211
5/105
AF30Z-30-11-23 1SBL276001R2311
5/105
AF30Z-30-22-20 1SBL276001R2022
5/105
AF30Z-30-22-21 1SBL276001R2122
5/105
AF30Z-30-22-22 1SBL276001R2222
5/105
AF30Z-30-22-23 1SBL276001R2322
5/105
AF370-30-00-11 1SFL607002R1100
5/90
AF370-30-00-12 1SFL607002R1200
5/90
AF370-30-00-13 1SFL607002R1300
5/90
AF370-30-00-14 1SFL607002R1400
5/90
AF370-30-00-33 1SFL607002R3300
5/91
AF370-30-00-34 1SFL607002R3400
5/91
AF370-30-11-11 1SFL607002R1111
5/96
AF370-30-11-12 1SFL607002R1211
5/96
AF370-30-11-13 1SFL607002R1311
5/96
ABB | 13/11
13
Index
Type
Index
Type classification
13
Order code
Page
Type
Order code
Page
Type
Order code
Page
AF370-30-11-14 1SFL607002R1411
5/96
AF460-30-11 1SFL597001R6811
5/100
AF96-30-11-12 1SBL407001R1211
5/107
AF370-30-11-33 1SFL607002R3311
5/97
1SFL597001R6911
5/100
AF96-30-11-13 1SBL407001R1311
5/107
AF370-30-11-34 1SFL607002R3411
5/97
1SFL597001R7011
5/100
AF96-30-11-14 1SBL407001R1411
5/107
AF370-30-22-11 1SFL607002R1122
5/112
1SFL597001R7111
5/100
AF96-30-11-41 1SBL407001R4111
5/107
AF370-30-22-12 1SFL607002R1222
5/112
AF460-30-22 1SFL597001R6822
5/116
AF96-30-22-11 1SBL407001R1122
5/107
AF370-30-22-13 1SFL607002R1322
5/112
1SFL597001R6922
5/116
AF96-30-22-12 1SBL407001R1222
5/107
AF370-30-22-14 1SFL607002R1422
5/112
1SFL597001R7022
5/116
AF96-30-22-13 1SBL407001R1322
5/107
AF370-30-22-33 1SFL607002R3322
5/113
1SFL597001R7122
5/116
AF96-30-22-14 1SBL407001R1422
5/107
AF370-30-22-34 1SFL607002R3422
5/113
AF52-30-00-11 1SBL367001R1100
5/84
AF96-30-22-41 1SBL407001R4122
5/107
AF370-40-00-11 1SFL607102R1100
5/189
AF52-30-00-12 1SBL367001R1200
5/84
AS09-30-01-16 1SBL101001R1601
4/32
AF370-40-00-12 1SFL607102R1200
5/189
AF52-30-00-13 1SBL367001R1300
5/84
AS09-30-01-20 1SBL101001R2001
4/32
AF370-40-00-13 1SFL607102R1300
5/189
AF52-30-00-14 1SBL367001R1400
5/84
AS09-30-01-26 1SBL101001R2601
4/32
AF370-40-00-14 1SFL607102R1400
5/189
AF52-30-00-41 1SBL367001R4100
5/84
AS09-30-01-28 1SBL101001R2801
4/32
AF370-40-11-11 1SFL607102R1111
5/193
AF52-30-11-11 1SBL367001R1111
5/106
AS09-30-01S-16 1SBL101004R1601
6/4
AF370-40-11-12 1SFL607102R1211
5/193
AF52-30-11-12 1SBL367001R1211
5/106
AS09-30-01S-20 1SBL101004R2001
6/4
AF370-40-11-13 1SFL607102R1311
5/193
AF52-30-11-13 1SBL367001R1311
5/106
AS09-30-01S-26 1SBL101004R2601
6/4
AF370-40-11-14 1SFL607102R1411
5/193
AF52-30-11-14 1SBL367001R1411
5/106
AS09-30-01S-28 1SBL101004R2801
6/4
AF370-40-22-11 1SFL607102R1122
5/197
AF52-30-11-41 1SBL367001R4111
5/106
AS09-30-10-16 1SBL101001R1610
4/32
AF370-40-22-12 1SFL607102R1222
5/197
AF52-30-22-11 1SBL367001R1122
5/106
AS09-30-10-20 1SBL101001R2010
4/32
AF370-40-22-13 1SFL607102R1322
5/197
AF52-30-22-12 1SBL367001R1222
5/106
AS09-30-10-26 1SBL101001R2610
4/32
AF370-40-22-14 1SFL607102R1422
5/197
AF52-30-22-13 1SBL367001R1322
5/106
AS09-30-10-28 1SBL101001R2810
4/32
AF38-22-00-12 1SBL297501R1200
5/182
AF52-30-22-14 1SBL367001R1422
5/106
AS09-30-10S-16 1SBL101004R1610
6/4
AF38-22-00-13 1SBL297501R1300
5/182
AF52-30-22-41 1SBL367001R4122
5/106
AS09-30-10S-20 1SBL101004R2010
6/4
AF38-22-00-14 1SBL297501R1400
5/182
AF52-40-00-11 1SBL367201R1100
5/184
AS09-30-10S-26 1SBL101004R2610
6/4
AF38-22-00-41 1SBL297501R4100
5/182
AF52-40-00-12 1SBL367201R1200
5/184
AS09-30-10S-28 1SBL101004R2810
6/4
AF38-30-00-12 1SBL297001R1200
5/82
AF52-40-00-13 1SBL367201R1300
5/184
AS09-30-32-16 1SBL101001R1632
4/34
AF38-30-00-13 1SBL297001R1300
5/82
AF52-40-00-14 1SBL367201R1400
5/184
AS09-30-32-20 1SBL101001R2032
4/34
AF38-30-00-14 1SBL297001R1400
5/82
AF52-40-00-41 1SBL367201R4100
5/184
AS09-30-32-26 1SBL101001R2632
4/34
AF38-30-00-41 1SBL297001R4100
5/82
AF580-30-11 1SFL617001R6811
5/100
AS09-30-32-28 1SBL101001R2832
4/34
AF38-30-11-12 1SBL297001R1211
5/104
1SFL617001R6911
5/100
AS09-30-32S-16 1SBL101004R1632
6/6
AF38-30-11-13 1SBL297001R1311
5/104
1SFL617001R7011
5/100
AS09-30-32S-20 1SBL101004R2032
6/6
AF38-30-11-14 1SBL297001R1411
5/104
1SFL617001R7111
5/100
AS09-30-32S-26 1SBL101004R2632
6/6
AF38-30-11-41 1SBL297001R4111
5/104
AF580-30-22 1SFL617001R6822
5/116
AS09-30-32S-28 1SBL101004R2832
6/6
AF38-30-22-12 1SBL297001R1222
5/104
1SFL617001R6922
5/116
AS12-30-01-16 1SBL111001R1601
4/32
AF38-30-22-13 1SBL297001R1322
5/104
1SFL617001R7022
5/116
AS12-30-01-20 1SBL111001R2001
4/32
AF38-30-22-14 1SBL297001R1422
5/104
1SFL617001R7122
5/116
AS12-30-01-26 1SBL111001R2601
4/32
AF38-30-22-41 1SBL297001R4122
5/104
AF65-30-00-11 1SBL387001R1100
5/84
AS12-30-01-28 1SBL111001R2801
4/32
AF38-40-00-12 1SBL297201R1200
5/182
AF65-30-00-12 1SBL387001R1200
5/84
AS12-30-01S-16 1SBL111004R1601
6/4
AF38-40-00-13 1SBL297201R1300
5/182
AF65-30-00-13 1SBL387001R1300
5/84
AS12-30-01S-20 1SBL111004R2001
6/4
AF38-40-00-14 1SBL297201R1400
5/182
AF65-30-00-14 1SBL387001R1400
5/84
AS12-30-01S-26 1SBL111004R2601
6/4
AF38-40-00-41 1SBL297201R4100
5/182
AF65-30-00-41 1SBL387001R4100
5/84
AS12-30-01S-28 1SBL111004R2801
6/4
AF38Z-22-00-20 1SBL296501R2000
5/183
AF65-30-11-11 1SBL387001R1111
5/106
AS12-30-10-16 1SBL111001R1610
4/32
AF38Z-22-00-21 1SBL296501R2100
5/183
AF65-30-11-12 1SBL387001R1211
5/106
AS12-30-10-20 1SBL111001R2010
4/32
AF38Z-22-00-22 1SBL296501R2200
5/183
AF65-30-11-13 1SBL387001R1311
5/106
AS12-30-10-26 1SBL111001R2610
4/32
AF38Z-22-00-23 1SBL296501R2300
5/183
AF65-30-11-14 1SBL387001R1411
5/106
AS12-30-10-28 1SBL111001R2810
4/32
AF38Z-30-11-20 1SBL296001R2011
5/105
AF65-30-11-41 1SBL387001R4111
5/106
AS12-30-10S-16 1SBL111004R1610
6/4
AF38Z-30-11-21 1SBL296001R2111
5/105
AF65-30-22-11 1SBL387001R1122
5/106
AS12-30-10S-20 1SBL111004R2010
6/4
AF38Z-30-11-22 1SBL296001R2211
5/105
AF65-30-22-12 1SBL387001R1222
5/106
AS12-30-10S-26 1SBL111004R2610
6/4
AF38Z-30-11-23 1SBL296001R2311
5/105
AF65-30-22-13 1SBL387001R1322
5/106
AS12-30-10S-28 1SBL111004R2810
6/4
AF38Z-30-22-20 1SBL296001R2022
5/105
AF65-30-22-14 1SBL387001R1422
5/106
AS12-30-32-16 1SBL111001R1632
4/34
AF38Z-30-22-21 1SBL296001R2122
5/105
AF65-30-22-41 1SBL387001R4122
5/106
AS12-30-32-20 1SBL111001R2032
4/34
AF38Z-30-22-22 1SBL296001R2222
5/105
AF750-30-11 1SFL637001R6811
5/100
AS12-30-32-26 1SBL111001R2632
4/34
AF38Z-30-22-23 1SBL296001R2322
5/105
1SFL637001R6911
5/100
AS12-30-32-28 1SBL111001R2832
4/34
AF38Z-40-00-20 1SBL296201R2000
5/183
1SFL637001R7011
5/100
AS12-30-32S-16 1SBL111004R1632
6/6
AF38Z-40-00-21 1SBL296201R2100
5/183
1SFL637001R7111
5/100
AS12-30-32S-20 1SBL111004R2032
6/6
AF38Z-40-00-22 1SBL296201R2200
5/183
AF750-30-22 1SFL637001R6822
5/116
AS12-30-32S-26 1SBL111004R2632
6/6
AF38Z-40-00-23 1SBL296201R2300
5/183
1SFL637001R6922
5/116
AS12-30-32S-28 1SBL111004R2832
6/6
AF400-30-11 1SFL577001R6811
5/100
1SFL637001R7022
5/116
AS16-30-01-16 1SBL121001R1601
4/32
1SFL577001R6911
5/100
1SFL637001R7122
5/116
AS16-30-01-20 1SBL121001R2001
4/32
1SFL577001R7011
5/100
AF80-22-00-11 1SBL397501R1100
5/184
AS16-30-01-26 1SBL121001R2601
4/32
1SFL577001R7111
5/100
AF80-22-00-12 1SBL397501R1200
5/184
AS16-30-01-28 1SBL121001R2801
4/32
AF400-30-22 1SFL577001R6822
5/116
AF80-22-00-13 1SBL397501R1300
5/184
AS16-30-01S-16 1SBL121004R1601
6/4
1SFL577001R6922
5/116
AF80-22-00-14 1SBL397501R1400
5/184
AS16-30-01S-20 1SBL121004R2001
6/4
1SFL577001R7022
5/116
AF80-22-00-41 1SBL397501R4100
5/184
AS16-30-01S-26 1SBL121004R2601
6/4
1SFL577001R7122
5/116
AF80-30-00-11 1SBL397001R1100
5/84
AS16-30-01S-28 1SBL121004R2801
6/4
AF40-22-00-11 1SBL347501R1100
5/184
AF80-30-00-12 1SBL397001R1200
5/84
AS16-30-10-16 1SBL121001R1610
4/32
AF40-22-00-12 1SBL347501R1200
5/184
AF80-30-00-13 1SBL397001R1300
5/84
AS16-30-10-20 1SBL121001R2010
4/32
AF40-22-00-13 1SBL347501R1300
5/184
AF80-30-00-14 1SBL397001R1400
5/84
AS16-30-10-26 1SBL121001R2610
4/32
AF40-22-00-14 1SBL347501R1400
5/184
AF80-30-00-41 1SBL397001R4100
5/84
AS16-30-10-28 1SBL121001R2810
4/32
AF40-22-00-41 1SBL347501R4100
5/184
AF80-30-11-11 1SBL397001R1111
5/107
AS16-30-10S-16 1SBL121004R1610
6/4
AF40-30-00-11 1SBL347001R1100
5/84
AF80-30-11-12 1SBL397001R1211
5/107
AS16-30-10S-20 1SBL121004R2010
6/4
AF40-30-00-12 1SBL347001R1200
5/84
AF80-30-11-13 1SBL397001R1311
5/107
AS16-30-10S-26 1SBL121004R2610
6/4
AF40-30-00-13 1SBL347001R1300
5/84
AF80-30-11-14 1SBL397001R1411
5/107
AS16-30-10S-28 1SBL121004R2810
6/4
AF40-30-00-14 1SBL347001R1400
5/84
AF80-30-11-41 1SBL397001R4111
5/107
AS16-30-32-16 1SBL121001R1632
4/34
AF40-30-00-41 1SBL347001R4100
5/84
AF80-30-22-11 1SBL397001R1122
5/107
AS16-30-32-20 1SBL121001R2032
4/34
AF40-30-11-11 1SBL347001R1111
5/106
AF80-30-22-12 1SBL397001R1222
5/107
AS16-30-32-26 1SBL121001R2632
4/34
AF40-30-11-12 1SBL347001R1211
5/106
AF80-30-22-13 1SBL397001R1322
5/107
AS16-30-32-28 1SBL121001R2832
4/34
AF40-30-11-13 1SBL347001R1311
5/106
AF80-30-22-14 1SBL397001R1422
5/107
AS16-30-32S-16 1SBL121004R1632
6/6
AF40-30-11-14 1SBL347001R1411
5/106
AF80-30-22-41 1SBL397001R4122
5/107
AS16-30-32S-20 1SBL121004R2032
6/6
AF40-30-11-41 1SBL347001R4111
5/106
AF80-40-00-11 1SBL397201R1100
5/184
AS16-30-32S-26 1SBL121004R2632
6/6
AF40-30-22-11 1SBL347001R1122
5/106
AF80-40-00-12 1SBL397201R1200
5/184
AS16-30-32S-28 1SBL121004R2832
6/6
AF40-30-22-12 1SBL347001R1222
5/106
AF80-40-00-13 1SBL397201R1300
5/184
ASL09-30-01-81 1SBL103001R8101
4/33
AF40-30-22-13 1SBL347001R1322
5/106
AF80-40-00-14 1SBL397201R1400
5/184
ASL09-30-01-83 1SBL103001R8301
4/33
AF40-30-22-14 1SBL347001R1422
5/106
AF80-40-00-41 1SBL397201R4100
5/184
ASL09-30-01-86 1SBL103001R8601
4/33
AF40-30-22-41 1SBL347001R4122
5/106
AF96-30-00-11 1SBL407001R1100
5/84
ASL09-30-01-88 1SBL103001R8801
4/33
AF40-40-00-11 1SBL347201R1100
5/184
AF96-30-00-12 1SBL407001R1200
5/84
ASL09-30-01S-81 1SBL103004R8101 6/5
AF40-40-00-12 1SBL347201R1200
5/184
AF96-30-00-13 1SBL407001R1300
5/84
ASL09-30-01S-83 1SBL103004R8301 6/5
AF40-40-00-13 1SBL347201R1300
5/184
AF96-30-00-14 1SBL407001R1400
5/84
ASL09-30-01S-86 1SBL103004R8601 6/5
AF40-40-00-14 1SBL347201R1400
5/184
AF96-30-00-41 1SBL407001R4100
5/84
ASL09-30-01S-88 1SBL103004R8801 6/5
AF40-40-00-41 1SBL347201R4100
5/184
AF96-30-11-11 1SBL407001R1111
5/107
ASL09-30-10-81 1SBL103001R8110
4/33
13/12 | ABB
Index
Type
Index
Type classification
Order code
Page
ASL09-30-10-83 1SBL103001R8310
4/33
ASL09-30-10-86 1SBL103001R8610
4/33
ASL09-30-10-88 1SBL103001R8810
4/33
ASL09-30-10S-81 1SBL103004R8110 6/5
ASL09-30-10S-83 1SBL103004R8310 6/5
ASL09-30-10S-86 1SBL103004R8610 6/5
ASL09-30-10S-88 1SBL103004R8810 6/5
ASL09-30-32-81 1SBL103001R8132
4/35
ASL09-30-32-83 1SBL103001R8332
4/35
ASL09-30-32-86 1SBL103001R8632
4/35
ASL09-30-32-88 1SBL103001R8832
4/35
ASL09-30-32S-81 1SBL103004R8132 6/7
ASL09-30-32S-83 1SBL103004R8332 6/7
ASL09-30-32S-86 1SBL103004R8632 6/7
ASL09-30-32S-88 1SBL103004R8832 6/7
ASL12-30-01-81 1SBL113001R8101
4/33
ASL12-30-01-83 1SBL113001R8301
4/33
ASL12-30-01-86 1SBL113001R8601
4/33
ASL12-30-01-88 1SBL113001R8801
4/33
ASL12-30-01S-81 1SBL113004R8101 6/5
ASL12-30-01S-83 1SBL113004R8301 6/5
ASL12-30-01S-86 1SBL113004R8601 6/5
ASL12-30-01S-88 1SBL113004R8801 6/5
ASL12-30-10-81 1SBL113001R8110
4/33
ASL12-30-10-83 1SBL113001R8310
4/33
ASL12-30-10-86 1SBL113001R8610
4/33
ASL12-30-10-88 1SBL113001R8810
4/33
ASL12-30-10S-81 1SBL113004R8110 6/5
ASL12-30-10S-83 1SBL113004R8310 6/5
ASL12-30-10S-86 1SBL113004R8610 6/5
ASL12-30-10S-88 1SBL113004R8810 6/5
ASL12-30-32-81 1SBL113001R8132
4/35
ASL12-30-32-83 1SBL113001R8332
4/35
ASL12-30-32-86 1SBL113001R8632
4/35
ASL12-30-32-88 1SBL113001R8832
4/35
ASL12-30-32S-81 1SBL113004R8132 6/7
ASL12-30-32S-83 1SBL113004R8332 6/7
ASL12-30-32S-86 1SBL113004R8632 6/7
ASL12-30-32S-88 1SBL113004R8832 6/7
ASL16-30-01-81 1SBL123001R8101
4/33
ASL16-30-01-83 1SBL123001R8301
4/33
ASL16-30-01-86 1SBL123001R8601
4/33
ASL16-30-01-88 1SBL123001R8801
4/33
ASL16-30-01S-81 1SBL123004R8101 6/5
ASL16-30-01S-83 1SBL123004R8301 6/5
ASL16-30-01S-86 1SBL123004R8601 6/5
ASL16-30-01S-88 1SBL123004R8801 6/5
ASL16-30-10-81 1SBL123001R8110
4/33
ASL16-30-10-83 1SBL123001R8310
4/33
ASL16-30-10-86 1SBL123001R8610
4/33
ASL16-30-10-88 1SBL123001R8810
4/33
ASL16-30-10S-81 1SBL123004R8110 6/5
ASL16-30-10S-83 1SBL123004R8310 6/5
ASL16-30-10S-86 1SBL123004R8610 6/5
ASL16-30-10S-88 1SBL123004R8810 6/5
ASL16-30-32-81 1SBL123001R8132
4/35
ASL16-30-32-83 1SBL123001R8332
4/35
ASL16-30-32-86 1SBL123001R8632
4/35
ASL16-30-32-88 1SBL123001R8832
4/35
ASL16-30-32S-81 1SBL123004R8132 6/7
ASL16-30-32S-83 1SBL123004R8332 6/7
ASL16-30-32S-86 1SBL123004R8632 6/7
ASL16-30-32S-88 1SBL123004R8832 6/7
B6-22-00-01 GJL1211501R0001
3/12
B6-22-00-02 GJL1211501R0002
3/12
B6-22-00-03 GJL1211501R0003
3/12
B6-22-00-80 GJL1211501R8000
3/12
B6-22-00-84 GJL1211501R8004
3/12
B6-30-01-01 GJL1211001R0011
3/4
B6-30-01-02 GJL1211001R0012
3/4
B6-30-01-03 GJL1211001R0013
3/4
B6-30-01-80 GJL1211001R8010
3/4
B6-30-01-84 GJL1211001R8014
3/4
B6-30-01-85 GJL1211001R8015
3/4
B6-30-01-F-01 GJL1211003R0011
3/29
B6-30-01-F-02 GJL1211003R0012
3/29
B6-30-01-F-03 GJL1211003R0013
3/29
B6-30-01-F-80 GJL1211003R8010
3/29
B6-30-01-F-84 GJL1211003R8014
3/29
B6-30-01-F-85 GJL1211003R8015
3/29
B6-30-01-P-01 GJL1211009R0011
3/19
B6-30-01-P-02 GJL1211009R0012
3/19
B6-30-01-P-03 GJL1211009R0013
3/19
B6-30-01-P-80 GJL1211009R8010
3/19
B6-30-01-P-84 GJL1211009R8014
3/19
B6-30-01-P-85 GJL1211009R8015
3/19
B6-30-10-01 GJL1211001R0101
3/4
B6-30-10-02 GJL1211001R0102
3/4
B6-30-10-03 GJL1211001R0103
3/4
B6-30-10-80 GJL1211001R8100
3/4
Type
Order code
Page
Type
Order code
Page
B6-30-10-84 GJL1211001R8104
3/4
BC6-22-00-03 GJL1213501R0003
3/13
B6-30-10-85 GJL1211001R8105
3/4
BC6-22-00-04 GJL1213501R0004
3/13
B6-30-10-F-01 GJL1211003R0101
3/29
BC6-22-00-05 GJL1213501R0005
3/13
B6-30-10-F-02 GJL1211003R0102
3/29
BC6-22-00-07 GJL1213501R0007
3/13
B6-30-10-F-03 GJL1211003R0103
3/29
BC6-22-00-16 GJL1213501R1006
3/13
B6-30-10-F-80 GJL1211003R8100
3/29
BC6-30-01-01 GJL1213001R0011
3/5
B6-30-10-F-84 GJL1211003R8104
3/29
BC6-30-01-03 GJL1213001R0013
3/5
B6-30-10-F-85 GJL1211003R8105
3/29
BC6-30-01-04 GJL1213001R0014
3/5
B6-30-10-P-01 GJL1211009R0101
3/19
BC6-30-01-05 GJL1213001R0015
3/5
B6-30-10-P-02 GJL1211009R0102
3/19
BC6-30-01-07 GJL1213001R0017
3/5
B6-30-10-P-03 GJL1211009R0103
3/19
BC6-30-01-1.4-81 GJL1213001R8011
3/10
B6-30-10-P-80 GJL1211009R8100
3/19
BC6-30-01-16 GJL1213001R1016
3/5
B6-30-10-P-84 GJL1211009R8104
3/19
BC6-30-01-2.4-51 GJL1213001R5011
3/10
B6-30-10-P-85 GJL1211009R8105
3/19
BC6-30-01-F-01 GJL1213003R0011
3/30
B6-40-00-01 GJL1211201R0001
3/12
BC6-30-01-F-03 GJL1213003R0013
3/30
B6-40-00-02 GJL1211201R0002
3/12
BC6-30-01-F-04 GJL1213003R0014
3/30
B6-40-00-03 GJL1211201R0003
3/12
BC6-30-01-F-05 GJL1213003R0015
3/30
B6-40-00-80 GJL1211201R8000
3/12
BC6-30-01-F-07 GJL1213003R0017
3/30
B6-40-00-84 GJL1211201R8004
3/12
BC6-30-01-F-1.4-81 GJL1213003R8011 3/35
B6S-30-01-1.7-71 GJL1213001R7011
3/10
BC6-30-01-F-16 GJL1213003R1016
3/30
B6S-30-01-2.8-72 GJL1213001R7012
3/10
BC6-30-01-F-2.4-51 GJL1213003R5011 3/35
B6S-30-10-1.7-71 GJL1213001R7101
3/10
BC6-30-01-P-01 GJL1213009R0011
3/20
B6S-30-10-2.8-72 GJL1213001R7102
3/10
BC6-30-01-P-03 GJL1213009R0013
3/20
B7-22-00-01 GJL1311501R0001
3/12
BC6-30-01-P-04 GJL1213009R0014
3/20
B7-22-00-02 GJL1311501R0002
3/12
BC6-30-01-P-05 GJL1213009R0015
3/20
B7-22-00-03 GJL1311501R0003
3/12
BC6-30-01-P-07 GJL1213009R0017
3/20
B7-22-00-80 GJL1311501R8000
3/12
BC6-30-01-P-1.4-81 GJL1213009R8011 3/27
B7-22-00-84 GJL1311501R8004
3/12
BC6-30-01-P-16 GJL1213009R1016
3/20
B7-30-01-01 GJL1311001R0011
3/4
BC6-30-01-P-2.4-51 GJL1213009R5011 3/27
B7-30-01-02 GJL1311001R0012
3/4
BC6-30-10-01 GJL1213001R0101
3/5
B7-30-01-03 GJL1311001R0013
3/4
BC6-30-10-03 GJL1213001R0103
3/5
B7-30-01-80 GJL1311001R8010
3/4
BC6-30-10-04 GJL1213001R0104
3/5
B7-30-01-84 GJL1311001R8014
3/4
BC6-30-10-05 GJL1213001R0105
3/5
B7-30-01-85 GJL1311001R8015
3/4
BC6-30-10-07 GJL1213001R0107
3/5
B7-30-01-F-01 GJL1311003R0011
3/29
BC6-30-10-1.4-81 GJL1213001R8101
3/10
B7-30-01-F-02 GJL1311003R0012
3/29
BC6-30-10-16 GJL1213001R1106
3/5
B7-30-01-F-03 GJL1311003R0013
3/29
BC6-30-10-2.4-51 GJL1213001R5101
3/10
B7-30-01-F-80 GJL1311003R8010
3/29
BC6-30-10-F-01 GJL1213003R0101
3/30
B7-30-01-F-84 GJL1311003R8014
3/29
BC6-30-10-F-03 GJL1213003R0103
3/30
B7-30-01-F-85 GJL1311003R8015
3/29
BC6-30-10-F-04 GJL1213003R0104
3/30
B7-30-01-P-01 GJL1311009R0011
3/19
BC6-30-10-F-05 GJL1213003R0105
3/30
B7-30-01-P-02 GJL1311009R0012
3/19
BC6-30-10-F-07 GJL1213003R0107
3/30
B7-30-01-P-03 GJL1311009R0013
3/19
BC6-30-10-F-1.4-81 GJL1213003R8101 3/35
B7-30-01-P-80 GJL1311009R8010
3/19
BC6-30-10-F-16 GJL1213003R1106
3/30
B7-30-01-P-84 GJL1311009R8014
3/19
BC6-30-10-F-2.4-51 GJL1213003R5101 3/35
B7-30-01-P-85 GJL1311009R8015
3/19
BC6-30-10-P-01 GJL1213009R0101
3/20
B7-30-10-01 GJL1311001R0101
3/4
BC6-30-10-P-03 GJL1213009R0103
3/20
B7-30-10-02 GJL1311001R0102
3/4
BC6-30-10-P-04 GJL1213009R0104
3/20
B7-30-10-03 GJL1311001R0103
3/4
BC6-30-10-P-05 GJL1213009R0105
3/20
B7-30-10-80 GJL1311001R8100
3/4
BC6-30-10-P-07 GJL1213009R0107
3/20
B7-30-10-84 GJL1311001R8104
3/4
BC6-30-10-P-1.4-81 GJL1213009R8101 3/27
B7-30-10-85 GJL1311001R8105
3/4
BC6-30-10-P-16 GJL1213009R1106
3/20
B7-30-10-F-01 GJL1311003R0101
3/29
BC6-30-10-P-2.4-51 GJL1213009R5101 3/27
B7-30-10-F-02 GJL1311003R0102
3/29
BC7-30-01-01 GJL1313001R0011
3/5
B7-30-10-F-03 GJL1311003R0103
3/29
BC7-30-01-03 GJL1313001R0013
3/5
B7-30-10-F-80 GJL1311003R8100
3/29
BC7-30-01-04 GJL1313001R0014
3/5
B7-30-10-F-84 GJL1311003R8104
3/29
BC7-30-01-05 GJL1313001R0015
3/5
B7-30-10-F-85 GJL1311003R8105
3/29
BC7-30-01-07 GJL1313001R0017
3/5
B7-30-10-P-01 GJL1311009R0101
3/19
BC7-30-01-1.4-81 GJL1313001R8011
3/10
B7-30-10-P-02 GJL1311009R0102
3/19
BC7-30-01-16 GJL1313001R1016
3/5
B7-30-10-P-03 GJL1311009R0103
3/19
BC7-30-01-2.4-51 GJL1313001R5011
3/10
B7-30-10-P-80 GJL1311009R8100
3/19
BC7-30-01-F-01 GJL1313003R0011
3/30
B7-30-10-P-84 GJL1311009R8104
3/19
BC7-30-01-F-03 GJL1313003R0013
3/30
B7-30-10-P-85 GJL1311009R8105
3/19
BC7-30-01-F-04 GJL1313003R0014
3/30
B7-40-00-01 GJL1311201R0001
3/12
BC7-30-01-F-05 GJL1313003R0015
3/30
B7-40-00-02 GJL1311201R0002
3/12
BC7-30-01-F-07 GJL1313003R0017
3/30
B7-40-00-03 GJL1311201R0003
3/12
BC7-30-01-F-1.4-81 GJL1313003R8011 3/35
B7-40-00-80 GJL1311201R8000
3/12
BC7-30-01-F-16 GJL1313003R1016
3/30
B7-40-00-84 GJL1311201R8004
3/12
BC7-30-01-F-2.4-51 GJL1313003R5011 3/35
B7D-30-01-01 GJL1317001R0011
3/5
BC7-30-01-P-01 GJL1313009R0011
3/20
B7D-30-01-05 GJL1317001R0015
3/5
BC7-30-01-P-03 GJL1313009R0013
3/20
B7D-30-10-01 GJL1317001R0101
3/5
BC7-30-01-P-04 GJL1313009R0014
3/20
B7D-30-10-05 GJL1317001R0105
3/5
BC7-30-01-P-05 GJL1313009R0015
3/20
B7D-40-00-01 GJL1317201R0001
3/13
BC7-30-01-P-07 GJL1313009R0017
3/20
B7D-40-00-05 GJL1317201R0005
3/13
BC7-30-01-P-1.4-81 GJL1313009R8011 3/27
B7S-30-01-1.7-71 GJL1313001R7011
3/10
BC7-30-01-P-16 GJL1313009R1016
3/20
B7S-30-01-2.8-72 GJL1313001R7012
3/10
BC7-30-01-P-2.4-51 GJL1313009R5011 3/27
B7S-30-10-1.7-71 GJL1313001R7101
3/10
BC7-30-10-01 GJL1313001R0101
3/5
B7S-30-10-2.8-72 GJL1313001R7102
3/10
BC7-30-10-03 GJL1313001R1103
3/5
BA4 1SNA235156R2700
4/82
BC7-30-10-04 GJL1313001R0104
3/5
BA5-50 1SBN110000R1000
3/39
BC7-30-10-05 GJL1313001R0105
3/5
BB3 1SBN111020R1000
4/82
BC7-30-10-07 GJL1313001R0107
3/5
BB4 1SBN110120W1000
5/338
BC7-30-10-1.4-81 GJL1313001R8101
3/10
BC6-21-10-P-01 GJL1213109R0101
3/20
BC7-30-10-16 GJL1313001R1106
3/5
BC6-21-10-P-03 GJL1213109R0103
3/20
BC7-30-10-2.4-51 GJL1313001R5101
3/10
BC6-21-10-P-04 GJL1213109R0104
3/20
BC7-30-10-F-01 GJL1313003R0101
3/30
BC6-21-10-P-05 GJL1213109R0105
3/20
BC7-30-10-F-03 GJL1313003R0103
3/30
BC6-21-10-P-16 GJL1213109R1106
3/20
BC7-30-10-F-04 GJL1313003R0104
3/30
BC6-22-00-01 GJL1213501R0001
3/13
BC7-30-10-F-05 GJL1313003R0105
3/30
BC6-22-00-02 GJL1213501R0002
3/13
BC7-30-10-F-07 GJL1313003R0107
3/30
ABB | 13/13
13
Index
Type
Index
Type classification
Type
Page
Type
Order code
Page
Type
Order code
Page
Index
13
Order code
BC7-30-10-F-1.4-81 GJL1313003R8101 3/35
CA4-22M 1SBN010140R1122
5/87
DB200 1SAZ401110R0001
7/24
BC7-30-10-F-16 GJL1313003R1106
3/30
CA4-22MS 1SBN010145R1122
6/51
DB42 1SAZ701902R0001
7/8
BC7-30-10-F-2.4-51 GJL1313003R5101 3/35
CA4-22N 1SBN010140R1222
5/307
DB45E 1SAX201110R1001
7/32
BC7-30-10-P-01 GJL1313009R0101
3/20
CA4-22NS 1SBN010145R1222
6/73
DB80E 1SAX301110R1001
7/32
BC7-30-10-P-03 GJL1313009R0103
3/20
CA4-22U 1SBN010140R1322
5/87
DMS132-G 1SAM201912R1010
2/22
BC7-30-10-P-04 GJL1313009R0104
3/20
CA4-31E 1SBN010140R1031
5/187
DMS132-Y 1SAM201912R1011
2/22
BC7-30-10-P-05 GJL1313009R0105
3/20
CA4-31ES 1SBN010145R1031
6/51
DRAS09-20S 1SBK104235R2000
8/2
BC7-30-10-P-07 GJL1313009R0107
3/20
CA4-31M 1SBN010140R1131
5/322
DRAS09-26N 1SBK104135R2600
8/2
BC7-30-10-P-1.4-81 GJL1313009R8101 3/27
CA4-31MS 1SBN010145R1131
6/51
DRAS09-27N 1SBK104135R2700
8/2
BC7-30-10-P-16 GJL1313009R1106
3/20
CA4-31N 1SBN010140R1231
5/307
DRAS09-28P 1SBK104035R2800
8/2
BC7-30-10-P-2.4-51 GJL1313009R5101 3/27
CA4-31NS 1SBN010145R1231
6/73
DRAS09-29P 1SBK104035R2900
8/2
BDT4 1SBN110122T1000
4/82
CA4-31U 1SBN010140R1331
5/322
DRAS12-20S 1SBK114235R2000
8/2
BEA140/XT2 1SFN084206R1000
5/352
CA4-40E 1SBN010140R1040
5/187
DRAS12-26N 1SBK114135R2600
8/2
BEA140/XT4 1SFN084206R1001
5/352
CA4-40ES 1SBN010145R1040
6/51
DRAS12-27N 1SBK114135R2700
8/2
BEA16-3 1SBN081006T1000
4/37
CA4-40N 1SBN010140R1240
5/307
DRAS12-28P 1SBK114035R2800
8/2
BEA16-3U 1SBN081020R1000
6/9
CA4-40NS 1SBN010145R1240
6/73
DRAS12-29P 1SBK114035R2900
8/2
BEA16-4 1SBN081306T1000
5/87
CA4-40U 1SBN010140R1340
5/322
DRAS16-20S 1SBK124235R2000
8/2
BEA205/T4 1SFN084806R1001
5/352
CA5-01 1SBN010010R1001
5/358
DRAS16-26N 1SBK124135R2600
8/2
BEA205/XT4 1SFN084806R1000
5/352
CA5-04E 1SBN010040R1004
5/358
DRAS16-27N 1SBK124135R2700
8/2
BEA26-4 1SBN082306T1000
5/87
CA5-04M 1SBN010040R1104
5/358
DRAS16-28P 1SBK124035R2800
8/2
BEA370/T5 1SFN085406R1000
5/352
CA5-10 1SBN010010R1010
5/358
DRAS16-29P 1SBK124035R2900
8/2
BEA38-4 1SBN082306T2000
5/87
CA5-11/11E 1SBN010040R1018
5/358
DRASL09-81S 1SBK104335R8100
8/2
BEA460H/T4 1SFN085907R1000
5/352
CA5-11/11M 1SBN010040R1118
5/358
DRASL09-83S 1SBK104335R8300
8/2
BEA7/132 1SBN080906R1002
3/39
CA5-13M 1SBN010040R1113
5/358
DRASL12-81S 1SBK114335R8100
8/2
BEA7/325 1SBN080906R1001
3/39
CA5-22E 1SBN010040R1022
5/358
DRASL12-83S 1SBK114335R8300
8/2
BEA750/T5 1SFN086106R1001
5/352
CA5-22M 1SBN010040R1122
5/358
DRASL16-81S 1SBK124335R8100
8/2
BEA750/T6 1SFN086106R1000
5/352
CA5-31E 1SBN010040R1031
5/358
DRASL16-83S 1SBK124335R8300
8/2
BEA750D/T5 1SFN086106R1003
5/352
CA5-31M 1SBN010040R1131
5/358
DX495 1SAM401912R1001
2/35
BEA750D/T6 1SFN086106R1002
5/352
CA5-40E 1SBN010040R1040
5/358
E1250DU-1250 1SFA739001R1000
7/48
BED460 1SFN085703R1000
5/351
CA6-11E GJL1201317R0002
3/39
E140DU-140 1SAX321001R1101
7/28
BED580 1SFN085903R1000
5/351
CA6-11E-F GJL1201318R0002
3/39
E16DU-0.32 1SAX111001R1101
7/28
BED750 1SFN086103R1000
5/351
CA6-11E-P GJL1201319R0002
3/39
E16DU-1.0 1SAX111001R1102
7/28
BEF460/OESA400 1SFN085708R1000
5/352
CA6-11K GJL1201317R0001
3/40
E16DU-18.9 1SAX111001R1105
7/28
BEF750/OESA800 1SFN086108R1000
5/352
CA6-11K-F GJL1201318R0001
3/40
E16DU-2.7 1SAX111001R1103
7/28
BEM460-30 1SFN085701R1000
5/350
CA6-11K-P GJL1201319R0001
3/40
E16DU-6.3 1SAX111001R1104
7/28
BEM750-30 1SFN086101R1000
5/350
CA6-11M GJL1201317R0003
3/39
E45DU-30 1SAX211001R1101
7/28
BEP140-30 1SFN084214R1000
5/350
CA6-11M-F GJL1201318R0003
3/39
E45DU-45 1SAX211001R1102
7/28
BEP140-40 1SFN084214R2000
5/350
CA6-11M-P GJL1201319R0003
3/39
E80DU-80 1SAX311001R1101
7/28
BEP205-30 1SFN084814R1000
5/350
CA6-11N GJL1201317R0004
3/39
EF146-150 1SAX351001R1101
7/37
BEP205-40 1SFN084814R2000
5/350
CA6-11N-F GJL1201318R0004
3/39
EF19-0.32 1SAX121001R1101
7/33
BEP370-30 1SFN085414R1000
5/350
CA6-11N-P GJL1201319R0004
3/39
EF19-1.0 1SAX121001R1102
7/33
BEP370-40 1SFN085414R2000
5/350
CAF6-02E GJL1201330R0010
3/39
EF19-18.9 1SAX121001R1105
7/33
BER140-4 1SFN084211R1000
5/350
CAF6-02K GJL1201330R0009
3/40
EF19-2.7 1SAX121001R1103
7/33
BER16-4 1SBN081311R1000
5/87
CAF6-02M GJL1201330R0011
3/39
EF19-6.3 1SAX121001R1104
7/33
BER16C-3 1SBN081012R1000
4/37
CAF6-02N GJL1201330R0012
3/39
EF205-210 1SAX531001R1101
7/41
BER205-4 1SFN084811R1000
5/350
CAF6-11E GJL1201330R0002
3/39
EF370-380 1SAX611001R1101
7/41
BER370-4 1SFN085411R1000
5/350
CAF6-11K GJL1201330R0001
3/40
EF45-30 1SAX221001R1101
7/33
BER38-4 1SBN082311R1000
5/87
CAF6-11M GJL1201330R0003
3/39
EF45-45 1SAX221001R1102
7/33
BER65-4 1SBN083411R1000
5/87
CAF6-11N GJL1201330R0004
3/39
EF460-500 1SAX721001R1101
7/45
BER96-4 1SBN083911R1000
5/87
CAF6-20E GJL1201330R0006
3/39
EF65-56 1SAX331001R1102
7/37
BES460 1SFN085704R1000
5/350
CAF6-20K GJL1201330R0005
3/40
EF65-70 1SAX331001R1101
7/37
BES750 1SFN086104R1000
5/350
CAF6-20M GJL1201330R0007
3/39
EF750-800 1SAX821001R1101
7/45
BEY140-4 1SFN084413R1000
5/351
CAF6-20N GJL1201330R0008
3/39
EF96-100 1SAX341001R1101
7/37
BEY16-4 1SBN081313R2000
5/87
CAL18-11 1SFN010720R1011
5/103
FR16AS-12VARS 1SBN101035R1000
8/2
BEY16C-3 1SBN081018R2000
4/37
CAL18-11B 1SFN010720R3311
5/103
FS116 1SAM201909R1001
2/20
BEY190-4 1SFN084813R1000
5/351
CAL19-11 1SFN010820R1011
5/93
GA75-10-00 1SBL411025R8000
5/242
1SBL411025R8100
5/242
BEY205-4 1SFN085213R1000
5/351
CAL19-11B 1SFN010820R3311
5/93
1SBL411025R8300
5/242
BEY265-4 1SFN085413R1000
5/351
CAL4-11 1SBN010120R1011
5/322
1SBL411025R8400
5/242
BEY370-4 1SFN085813R1000
5/351
CAL4-11S 1SBN010130R1011
6/51
1SBL411025R8500
5/242
BEY38-4 1SBN082713R2000
5/87
CAL4-11-T 1SBN010120T1011
5/322
1SBL411025R8600
5/242
BEY65-4 1SBN083413R2000
5/87
CAL5-11 1SBN010020R1011
5/358
1SBL411025R8800
5/242
BEY96-4 1SBN083913R2000
5/87
CAT4-11E 1SBN010151R1011
5/87
GA75-10-11 1SBL411025R8011
5/242
BP16 1SBN111403R1000
5/371
CAT4-11ES 1SBN010153R1011
6/51
1SBL411025R8111
5/242
BP38-4 1SBN112303T1000
5/345
CAT4-11M 1SBN010151R1111
5/87
1SBL411025R8311
5/242
BP65-4 1SBN113403T1000
5/345
CAT4-11MS 1SBN010153R1111
6/51
1SBL411025R8411
5/242
BP96-4 1SBN113903T1000
5/345
CAT4-11U 1SBN010151R1311
5/87
1SBL411025R8511
5/242
BS1-3 1SAM201908R1001
2/20
CAT4-11US 1SBN010153R1311
6/51
1SBL411025R8611
5/242
BS4-3 1SAM401911R1008
2/35
CB5-01 1SBN010013R1001
5/340
1SBL411025R8811
5/242
BSM6-30 GJL1201908R0001
3/39
CB5-10 1SBN010013R1010
5/340
GAE75-10-00 1SBL419025R8000
5/243
BX4 1SBN110108T1000
5/307
CC4-01 1SBN010111R1001
5/322
1SBL419025R8100
5/243
BX4-CA 1SBN110109W1000
5/307
CC4-10 1SBN010111R1010
5/322
1SBL419025R8300
5/243
CA3-01 1SBN011010T1001
4/37
CC5-01 1SBN010011R1001
5/358
1SBL419025R8400
5/243
CA3-01S 1SBN011019T1001
6/9
CC5-10 1SBN010011R1010
5/358
1SBL419025R8600
5/243
CA3-10 1SBN011010T1010
4/37
CE5-01D0.1 1SBN010015R1001
5/360
1SBL419025R8700
5/243
CA3-10S 1SBN011019T1010
6/9
CE5-01D2 1SBN010017R1001
5/360
1SBL419025R8800
5/243
CA4-01 1SBN010110R1001
5/87
CE5-01W0.1 1SBN010016R1001
5/360
1SBL419025R8900
5/243
CA4-01S 1SBN010119R1001
6/51
CE5-01W2 1SBN010018R1001
5/360
GAE75-10-11 1SBL419025R8011
5/243
CA4-01S-T 1SBN010119T1001
6/51
CE5-10D0.1 1SBN010015R1010
5/360
1SBL419025R8111
5/243
CA4-01-T 1SBN010110T1001
5/87
CE5-10D2 1SBN010017R1010
5/360
1SBL419025R8311
5/243
CA4-04E 1SBN010140R1004
5/187
CE5-10W0.1 1SBN010016R1010
5/360
1SBL419025R8411
5/243
CA4-04M 1SBN010140R1104
5/322
CE5-10W2 1SBN010018R1010
5/360
1SBL419025R8611
5/243
CA4-04N 1SBN010140R1204
5/307
CEL18-01 1SFN010716R1001
5/247
1SBL419025R8711
5/243
CA4-10 1SBN010110R1010
5/87
CEL18-10 1SFN010716R1010
5/247
1SBL419025R8811
5/243
CA4-10S 1SBN010119R1010
6/51
CK1-02 1SAM301901R1003
2/15
1SBL419025R8911
5/243
CA4-10S-T 1SBN010119T1010
6/51
CK1-11 1SAM301901R1001
2/15
GAF1250-10-11 1SFL647025R6811
5/246
CA4-10-T 1SBN010110T1010
5/87
CK1-20 1SAM301901R1002
2/15
1SFL647025R6911
5/246
CA4-13M 1SBN010140R1113
5/322
DB140E 1SAX301110R1002
7/32
1SFL647025R7011
5/246
CA4-13N 1SBN010140R1213
5/307
DB16 1SAZ701901R0001
7/4
1SFL647025R7111
5/246
CA4-22E 1SBN010140R1022
5/87
DB16E 1SAX101110R0001
7/32
GAF1650-10-11 1SFL677025R7011
5/246
CA4-22ES 1SBN010145R1022
6/51
DB19EF 1SAX101910R1001
7/33
13/14 | ABB
Index
Type classification
Type
Order code
Page
Type
Order code
Page
Type
Order code
Page
KA495 1SAM501901R1001
2/35
GAF185-10-11 1SFL497025R6911
5/244
LT205-30L 1SFN124803R1000
5/93
KA495C 1SAM501902R1001
2/35
1SFL497025R7011
5/244
LT205-30Y 1SFN124804R1000
5/93
KC6-22Z-01 GJH1213001R0221
3/16
1SFL497025R7211
5/244
LT205-40C 1SFN124801R2000
5/191
KC6-22Z-03 GJH1213001R0223
3/16
GAF2050-10-11 1SFL707025R7011
5/246
LT205-40L 1SFN124803R2000
5/191
KC6-22Z-04 GJH1213001R0224
3/16
GAF300-10-11 1SFL557025R6911
5/244
LT370-30C 1SFN125401R1000
5/93
KC6-22Z-05 GJH1213001R0225
3/16
1SFL557025R7011
5/244
LT370-30D 1SFN125406R1000
5/93
KC6-22Z-07 GJH1213001R0227
3/16
1SFL557025R7211
5/244
LT370-30L 1SFN125403R1000
5/93
KC6-22Z-16 GJH1213001R1226
3/16
GAF460-10-11 1SFL597025R6811
5/245
LT370-30Y 1SFN125404R1000
5/93
KC6-22Z-F-01 GJH1213003R0221
3/37
1SFL597025R6911
5/245
LT370-40C 1SFN125401R2000
5/191
KC6-22Z-F-04 GJH1213003R0224
3/37
1SFL597025R7011
5/245
LT370-40L 1SFN125403R2000
5/191
KC6-22Z-F-05 GJH1213003R0225
3/37
1SFL597025R7111
5/245
LT460-AC 1SFN125701R1000
5/103
KC6-22Z-F-07 GJH1213003R0227
3/37
GAF750-10-11 1SFL637025R6811
5/245
LT460-AL 1SFN125703R1000
5/103
KC6-22Z-F-16 GJH1213003R1226
3/37
1SFL637025R6911
5/245
LT6-B GJL1201906R0001
3/39
KC6-22Z-P-01 GJH1213009R0221
3/26
1SFL637025R7011
5/245
LT750-AC 1SFN126101R1000
5/103
KC6-22Z-P-04 GJH1213009R0224
3/26
1SFL637025R7111
5/245
LT750-AL 1SFN126103R1000
5/103
KC6-22Z-P-05 GJH1213009R0225
3/26
HK1-02 1SAM201902R1003
2/15
LW110 1SFN074307R1000
5/378
KC6-22Z-P-07 GJH1213009R0227
3/26
HK1-11 1SAM201902R1001
2/15
LW1250 1SFN076407R1000
5/103
KC6-22Z-P-16 GJH1213009R1226
3/26
HK1-20 1SAM201902R1002
2/15
LW140 1SFN074207R1000
5/93
KC6-31Z-01 GJH1213001R0311
3/16
HK1-20L 1SAM201902R1004
2/15
LW205 1SFN074807R1000
5/93
KC6-31Z-03 GJH1213001R0313
3/16
HK4-11 1SAM401901R1001
2/32
LW205-40 1SFN074807R2000
5/191
KC6-31Z-04 GJH1213001R0314
3/16
HK4-W 1SAM401901R1002
2/32
LW370 1SFN075407R1000
5/93
KC6-31Z-05 GJH1213001R0315
3/16
HKF1-11 1SAM201901R1001
2/15
LW370-40 1SFN075407R2000
5/191
KC6-31Z-07 GJH1213001R0317
3/16
HKF1-20 1SAM201901R1002
2/15
LW460 1SFN075707R1000
5/103
KC6-31Z-1.4-81 GJH1213001R8311
3/17
HKS4-02 1SAM401902R1003
2/32
LW750 1SFN076107R1000
5/103
KC6-31Z-16 GJH1213001R1316
3/16
HKS4-11 1SAM401902R1001
2/32
LX140 1SFN074210R1000
5/93
KC6-31Z-2.4-51 GJH1213001R5311
3/17
HKS4-20 1SAM401902R1002
2/32
LX205 1SFN074810R1000
5/93
KC6-31Z-F-01 GJH1213003R0311
3/37
HTP500-BA4 1SNA235712R2400
4/82
LX370 1SFN075410R1000
5/93
KC6-31Z-F-04 GJH1213003R0314
3/37
IB132-G 1SAM201911R1010
2/22
LX460 1SFN075710R1000
5/103
KC6-31Z-F-05 GJH1213003R0315
3/37
IB132-Y 1SAM201911R1011
2/22
LX750 1SFN076110R1000
5/103
KC6-31Z-F-07 GJH1213003R0317
3/37
K6-22Z-01 GJH1211001R0221
3/15
LY140 1SFN074203R1000
5/349
KC6-31Z-F-1.4-81 GJH1213003R8311
3/38
K6-22Z-02 GJH1211001R0222
3/15
LY16-4 1SBN071303T1000
5/349
KC6-31Z-F-16 GJH1213003R1316
3/37
K6-22Z-03 GJH1211001R0223
3/15
LY185 1SFN074703R1000
5/349
KC6-31Z-F-51 GJH1213003R5311
3/38
K6-22Z-80 GJH1211001R8220
3/15
LY300 1SFN075103R1000
5/349
KC6-31Z-P-01 GJH1213009R0311
3/26
K6-22Z-84 GJH1211001R8224
3/15
LY38-4 1SBN072303T1000
5/349
KC6-31Z-P-04 GJH1213009R0314
3/26
K6-22Z-85 GJH1211001R8225
3/15
LY460 1SFN075703R1000
5/349
KC6-31Z-P-05 GJH1213009R0315
3/26
K6-22Z-F-01 GJH1211003R0221
3/36
LY750 1SFN076103R1000
5/349
KC6-31Z-P-1.4-81 GJH1213009R8311
3/28
K6-22Z-F-02 GJH1211003R0222
3/36
MO132-0.16 1SAM360000R1001
2/6
KC6-31Z-P-16 GJH1213009R1316
3/26
K6-22Z-F-03 GJH1211003R0223
3/36
MO132-0.25 1SAM360000R1002
2/6
KC6-31Z-P-2.4-51 GJH1213009R5311
3/28
K6-22Z-F-80 GJH1211003R8220
3/36
MO132-0.4 1SAM360000R1003
2/6
KC6-40E-01 GJH1213001R0401
3/16
K6-22Z-F-84 GJH1211003R8224
3/36
MO132-0.63 1SAM360000R1004
2/6
KC6-40E-03 GJH1213001R0403
3/16
K6-22Z-F-85 GJH1211003R8225
3/36
MO132-1.0 1SAM360000R1005
2/6
KC6-40E-04 GJH1213001R0404
3/16
K6-22Z-P-01 GJH1211009R0221
3/25
MO132-1.6 1SAM360000R1006
2/6
KC6-40E-05 GJH1213001R0405
3/16
K6-22Z-P-02 GJH1211009R0222
3/25
MO132-10 1SAM360000R1010
2/6
KC6-40E-07 GJH1213001R0407
3/16
K6-22Z-P-03 GJH1211009R0223
3/25
MO132-12 1SAM360000R1012
2/6
KC6-40E-1.4-81 GJH1213001R8401
3/17
K6-22Z-P-80 GJH1211009R8220
3/25
MO132-16 1SAM360000R1011
2/6
KC6-40E-16 GJH1213001R1406
3/16
K6-22Z-P-84 GJH1211009R8224
3/25
MO132-2.5 1SAM360000R1007
2/6
KC6-40E-2.4-51 GJH1213001R5401
3/17
K6-22Z-P-85 GJH1211009R8225
3/25
MO132-20 1SAM360000R1013
2/6
KC6-40E-F-01 GJH1213003R0401
3/37
K6-31Z-01 GJH1211001R0311
3/15
MO132-25 1SAM360000R1014
2/6
KC6-40E-F-04 GJH1213003R0404
3/37
K6-31Z-02 GJH1211001R0312
3/15
MO132-32 1SAM360000R1015
2/6
KC6-40E-F-05 GJH1213003R0405
3/37
K6-31Z-03 GJH1211001R0313
3/15
MO132-4.0 1SAM360000R1008
2/6
KC6-40E-F-1.4-81 GJH1213003R8401
3/38
K6-31Z-80 GJH1211001R8310
3/15
MO132-6.3 1SAM360000R1009
2/6
KC6-40E-F-16 GJH1213003R1406
3/37
K6-31Z-84 GJH1211001R8314
3/15
MO450-40 1SAM460000R1005
2/27
KC6-40E-F-51 GJH1213003R5401
3/38
K6-31Z-85 GJH1211001R8315
3/15
MO450-45 1SAM460000R1006
2/27
KC6-40E-P-01 GJH1213009R0401
3/26
K6-31Z-F-01 GJH1211003R0311
3/36
MO450-50 1SAM460000R1007
2/27
KC6-40E-P-04 GJH1213009R0404
3/26
K6-31Z-F-02 GJH1211003R0312
3/36
MO495-100 1SAM560000R1010
2/27
KC6-40E-P-05 GJH1213009R0405
3/26
K6-31Z-F-03 GJH1211003R0313
3/36
MO495-63 1SAM560000R1007
2/27
KC6-40E-P-07 GJH1213009R0407
3/26
K6-31Z-F-80 GJH1211003R8310
3/36
MO495-75 1SAM560000R1008
2/27
KC6-40E-P-1.4-81 GJH1213009R8401
3/28
K6-31Z-F-84 GJH1211003R8314
3/36
MO495-90 1SAM560000R1009
2/27
KC6-40E-P-16 GJH1213009R1406
3/26
K6-31Z-F-85 GJH1211003R8315
3/36
MO496-100 1SAM590000R1010
2/27
KC6-40E-P-2.4-51 GJH1213009R5401
3/28
K6-31Z-P-01 GJH1211009R0311
3/25
MO496-32 1SAM590000R1004
2/27
KPR-101L 1SFA616162R1014
7/4
K6-31Z-P-02 GJH1211009R0312
3/25
MO496-40 1SAM590000R1005
2/27
LB6 GJL1201902R0001
3/39
K6-31Z-P-03 GJH1211009R0313
3/25
MO496-50 1SAM590000R1006
2/27
LB6-CA GJL1201903R0001
3/39
K6-31Z-P-80 GJH1211009R8310
3/25
MO496-63 1SAM590000R1007
2/27
LD146-30 1SFN074208R1000
5/348
K6-31Z-P-84 GJH1211009R8314
3/25
MO496-75 1SAM590000R1008
2/27
LD146-40 1SFN074208R2000
5/348
K6-31Z-P-85 GJH1211009R8315
3/25
MO496-90 1SAM590000R1009
2/27
LD38-4 1SBN072308R1000
5/346
K6-40E-01 GJH1211001R0401
3/15
MS116-0.16 1SAM250000R1001
2/4
LD75 1SBN073508R1000
5/378
K6-40E-02 GJH1211001R0402
3/15
MS116-0.16-HKF1-11 1SAM250005R1001 2/4
LDC4 1SBN070156T1000
5/307
K6-40E-03 GJH1211001R0403
3/15
MS116-0.25 1SAM250000R1002
2/4
LDC4S 1SBN070157T1000
6/51
K6-40E-80 GJH1211001R8400
3/15
MS116-0.25-HKF1-11 1SAM250005R1002 2/4
LF16-4 1SBN071305R1000
5/349
K6-40E-84 GJH1211001R8404
3/15
MS116-0.4 1SAM250000R1003
2/4
LF38-4 1SBN072305R1000
5/349
K6-40E-85 GJH1211001R8405
3/15
MS116-0.4-HKF1-11 1SAM250005R1003 2/4
LG16-4 1SBN071306R1000
5/349
K6-40E-F-01 GJH1211003R0401
3/36
MS116-0.63 1SAM250000R1004
2/4
LH38-4 1SBN072304R1000
5/349
K6-40E-F-02 GJH1211003R0402
3/36
MS116-0.63-HKF1-11 1SAM250005R1004 2/4
LK75-F 1SBN073552R1002
5/379
K6-40E-F-03 GJH1211003R0403
3/36
MS116-1.0 1SAM250000R1005
2/4
LK75-L 1SBN073552R1003
5/379
K6-40E-F-80 GJH1211003R8400
3/36
MS116-1.0-HKF1-11 1SAM250005R1005 2/4
LL146-30 1SFN074211R1000
5/348
K6-40E-F-84 GJH1211003R8404
3/36
MS116-1.6 1SAM250000R1006
2/4
LL146-40 1SFN074211R2000
5/348
K6-40E-F-85 GJH1211003R8405
3/36
MS116-1.6-HKF1-11 1SAM250005R1006 2/4
LL205-40 1SFN074811R2000
5/348
K6-40E-P-01 GJH1211009R0401
3/25
MS116-10 1SAM250000R1010
2/4
LL370-40 1SFN075411R2000
5/348
K6-40E-P-02 GJH1211009R0402
3/25
MS116-10.0-HKF1-11 1SAM250005R1010 2/4
LP1250 1SFN076412R1000
5/247
K6-40E-P-03 GJH1211009R0403
3/25
MS116-12 1SAM250000R1012
2/4
LP185 1SFN074712R1000
5/247
K6-40E-P-80 GJH1211009R8400
3/25
MS116-12.0-HKF1-11 1SAM250005R1012 2/4
LP2050 1SFN076512R1000
5/247
K6-40E-P-84 GJH1211009R8404
3/25
MS116-16 1SAM250000R1011
2/4
LP300 1SFN075112R1000
5/247
K6-40E-P-85 GJH1211009R8405
3/25
MS116-16.0-HKF1-11 1SAM250005R1011 2/4
LP460 1SFN075712R1000
5/247
K6S-22Z-1.7-71 GJH1213001R7221
3/17
MS116-2.5 1SAM250000R1007
2/4
LP6 GJL1201907R0001
3/39
K6S-22Z-2.8-72 GJH1213001R7222
3/17
MS116-2.5-HKF1-11 1SAM250005R1007 2/4
LP750 1SFN076112R1000
5/247
K6S-31Z-1.7-71 GJH1213001R7311
3/17
MS116-20 1SAM250000R1013
2/4
LT140-30L 1SFN124203R1000
5/93
K6S-31Z-2.8-72 GJH1213001R7312
3/17
MS116-20-HKF1-11 1SAM250005R1013 2/4
LT140-40L 1SFN124203R2000
5/191
K6S-40E-1.7-71 GJH1213001R7401
3/17
MS116-25 1SAM250000R1014
2/4
LT200/A 1SAZ401901R1001
7/24
K6S-40E-2.8-72 GJH1213001R7402
3/17
MS116-25-HKF1-11 1SAM250005R1014 2/4
LT205-30C 1SFN124801R1000
5/93
KA450 1SAM401908R1001
2/35
MS116-32 1SAM250000R1015
2/4
Index
13
ABB | 13/15
Index
Type classification
Type
Page
Type
Order code
Page
Type
Order code
Page
Index
13
Order code
MS116-32-HKF1-11 1SAM250005R1015 2/4
NF33/11-41 1SBH137001R4139
5/308
NFZ51/11-21 1SBH136001R2159
5/309
MS116-4.0 1SAM250000R1008
2/4
NF40E-12 1SBH137001R1240
5/304
NFZ51/11-22 1SBH136001R2259
5/309
MS116-4.0-HKF1-11 1SAM250005R1008 2/4
NF40E-13 1SBH137001R1340
5/304
NFZ51/11-23 1SBH136001R2359
5/309
MS116-6.3 1SAM250000R1009
2/4
NF40E-14 1SBH137001R1440
5/304
NFZ53E-20 1SBH136001R2053
5/309
MS116-6.3-HKF1-11 1SAM250005R1009 2/4
NF40E-41 1SBH137001R4140
5/304
NFZ53E-21 1SBH136001R2153
5/309
MS132-0.16 1SAM350000R1001
2/5
NF40ES-12 1SBH137004R1240
6/68
NFZ53E-22 1SBH136001R2253
5/309
MS132-0.16-HKF1-11 1SAM350005R1001 2/5
NF40ES-13 1SBH137004R1340
6/68
NFZ53E-23 1SBH136001R2353
5/309
MS132-0.16T 1SAM340000R1001
2/7
NF40ES-14 1SBH137004R1440
6/68
NFZ53ES-20 1SBH136004R2053
6/71
MS132-0.25 1SAM350000R1002
2/5
NF40ES-41 1SBH137004R4140
6/68
NFZ53ES-21 1SBH136004R2153
6/71
MS132-0.25-HKF1-11 1SAM350005R1002 2/5
NF44E-12 1SBH137001R1244
5/308
NFZ53ES-22 1SBH136004R2253
6/71
MS132-0.25T 1SAM340000R1002
2/7
NF44E-13 1SBH137001R1344
5/308
NFZ53ES-23 1SBH136004R2353
6/71
MS132-0.4 1SAM350000R1003
2/5
NF44E-14 1SBH137001R1444
5/308
NFZ62E-20 1SBH136001R2062
5/309
MS132-0.4-HKF1-11 1SAM350005R1003 2/5
NF44E-41 1SBH137001R4144
5/308
NFZ62E-21 1SBH136001R2162
5/309
MS132-0.4T 1SAM340000R1003
2/7
NF44ES-12 1SBH137004R1244
6/70
NFZ62E-22 1SBH136001R2262
5/309
MS132-0.63 1SAM350000R1004
2/5
NF44ES-13 1SBH137004R1344
6/70
NFZ62E-23 1SBH136001R2362
5/309
MS132-0.63-HKF1-11 1SAM350005R1004 2/5
NF44ES-14 1SBH137004R1444
6/70
NFZ62ES-20 1SBH136004R2062
6/71
MS132-0.63T 1SAM340000R1004
2/7
NF44ES-41 1SBH137004R4144
6/70
NFZ62ES-21 1SBH136004R2162
6/71
MS132-1.0 1SAM350000R1005
2/5
NF51/11-12 1SBH137001R1259
5/308
NFZ62ES-22 1SBH136004R2262
6/71
MS132-1.0-HKF1-11 1SAM350005R1005 2/5
NF51/11-13 1SBH137001R1359
5/308
NFZ62ES-23 1SBH136004R2362
6/71
MS132-1.0T 1SAM340000R1005
2/7
NF51/11-14 1SBH137001R1459
5/308
NFZ71E-20 1SBH136001R2071
5/309
MS132-1.6 1SAM350000R1006
2/5
NF51/11-41 1SBH137001R4159
5/308
NFZ71E-21 1SBH136001R2171
5/309
MS132-1.6-HKF1-11 1SAM350005R1006 2/5
NF53E-12 1SBH137001R1253
5/308
NFZ71E-22 1SBH136001R2271
5/309
MS132-1.6T 1SAM340000R1006
2/7
NF53E-13 1SBH137001R1353
5/308
NFZ71E-23 1SBH136001R2371
5/309
MS132-10 1SAM350000R1010
2/5
NF53E-14 1SBH137001R1453
5/308
NFZ71ES-20 1SBH136004R2071
6/71
MS132-10.0-HKF1-11 1SAM350005R1010 2/5
NF53E-41 1SBH137001R4153
5/308
NFZ71ES-21 1SBH136004R2171
6/71
MS132-10T 1SAM340000R1010
2/7
NF53ES-12 1SBH137004R1253
6/70
NFZ71ES-22 1SBH136004R2271
6/71
MS132-12 1SAM350000R1012
2/5
NF53ES-13 1SBH137004R1353
6/70
NFZ71ES-23 1SBH136004R2371
6/71
MS132-12.0-HKF1-11 1SAM350005R1012 2/5
NF53ES-14 1SBH137004R1453
6/70
NFZ80E-20 1SBH136001R2080
5/309
MS132-12T 1SAM340000R1012
2/7
NF53ES-41 1SBH137004R4153
6/70
NFZ80E-21 1SBH136001R2180
5/309
MS132-16 1SAM350000R1011
2/5
NF62E-12 1SBH137001R1262
5/308
NFZ80E-22 1SBH136001R2280
5/309
MS132-16.0-HKF1-11 1SAM350005R1011 2/5
NF62E-13 1SBH137001R1362
5/308
NFZ80E-23 1SBH136001R2380
5/309
MS132-16T 1SAM340000R1011
2/7
NF62E-14 1SBH137001R1462
5/308
NFZ80ES-20 1SBH136004R2080
6/71
MS132-2.5 1SAM350000R1007
2/5
NF62E-41 1SBH137001R4162
5/308
NFZ80ES-21 1SBH136004R2180
6/71
MS132-2.5-HKF1-11 1SAM350005R1007 2/5
NF62ES-12 1SBH137004R1262
6/70
NFZ80ES-22 1SBH136004R2280
6/71
MS132-2.5T 1SAM340000R1007
2/7
NF62ES-13 1SBH137004R1362
6/70
NFZ80ES-23 1SBH136004R2380
6/71
MS132-20 1SAM350000R1013
2/5
NF62ES-14 1SBH137004R1462
6/70
NS22E-16 1SBH101001R1622
4/62
MS132-20-HKF1-11 1SAM350005R1013 2/5
NF62ES-41 1SBH137004R4162
6/70
NS22E-20 1SBH101001R2022
4/62
MS132-20T 1SAM340000R1013
2/7
NF71E-12 1SBH137001R1271
5/308
NS22E-26 1SBH101001R2622
4/62
MS132-25 1SAM350000R1014
2/5
NF71E-13 1SBH137001R1371
5/308
NS22E-28 1SBH101001R2822
4/62
MS132-25-HKF1-11 1SAM350005R1014 2/5
NF71E-14 1SBH137001R1471
5/308
NS22ES-16 1SBH101004R1622
6/22
MS132-25T 1SAM340000R1014
2/7
NF71E-41 1SBH137001R4171
5/308
NS22ES-20 1SBH101004R2022
6/22
MS132-32 1SAM350000R1015
2/5
NF71ES-12 1SBH137004R1271
6/70
NS22ES-26 1SBH101004R2622
6/22
MS132-32-HKF1-11 1SAM350005R1015 2/5
NF71ES-13 1SBH137004R1371
6/70
NS22ES-28 1SBH101004R2822
6/22
MS132-4.0 1SAM350000R1008
2/5
NF71ES-14 1SBH137004R1471
6/70
NS31E-16 1SBH101001R1631
4/62
MS132-4.0-HKF1-11 1SAM350005R1008 2/5
NF71ES-41 1SBH137004R4171
6/70
NS31E-20 1SBH101001R2031
4/62
MS132-4.0T 1SAM340000R1008
2/7
NF80E-12 1SBH137001R1280
5/308
NS31E-26 1SBH101001R2631
4/62
MS132-6.3 1SAM350000R1009
2/5
NF80E-13 1SBH137001R1380
5/308
NS31E-28 1SBH101001R2831
4/62
MS132-6.3-HKF1-11 1SAM350005R1009 2/5
NF80E-14 1SBH137001R1480
5/308
NS31ES-16 1SBH101004R1631
6/22
MS132-6.3T 1SAM340000R1009
2/7
NF80E-41 1SBH137001R4180
5/308
NS31ES-20 1SBH101004R2031
6/22
MS450-40 1SAM450000R1005
2/23
NF80ES-12 1SBH137004R1280
6/70
NS31ES-26 1SBH101004R2631
6/22
MS450-45 1SAM450000R1006
2/23
NF80ES-13 1SBH137004R1380
6/70
NS31ES-28 1SBH101004R2831
6/22
MS450-50 1SAM450000R1007
2/23
NF80ES-14 1SBH137004R1480
6/70
NS40E-16 1SBH101001R1640
4/62
MS495-100 1SAM550000R1010
2/23
NF80ES-41 1SBH137004R4180
6/70
NS40E-20 1SBH101001R2040
4/62
MS495-63 1SAM550000R1007
2/23
NFZ22E-20 1SBH136001R2022
5/305
NS40E-26 1SBH101001R2640
4/62
MS495-75 1SAM550000R1008
2/23
NFZ22E-21 1SBH136001R2122
5/305
NS40E-28 1SBH101001R2840
4/62
MS495-90 1SAM550000R1009
2/23
NFZ22E-22 1SBH136001R2222
5/305
NS40ES-16 1SBH101004R1640
6/22
MS497-100 1SAM580000R1010
2/23
NFZ22E-23 1SBH136001R2322
5/305
NS40ES-20 1SBH101004R2040
6/22
MS497-32 1SAM580000R1004
2/23
NFZ22ES-20 1SBH136004R2022
6/69
NS40ES-26 1SBH101004R2640
6/22
MS497-40 1SAM580000R1005
2/23
NFZ22ES-21 1SBH136004R2122
6/69
NS40ES-28 1SBH101004R2840
6/22
MS497-50 1SAM580000R1006
2/23
NFZ22ES-22 1SBH136004R2222
6/69
NS44E-16 1SBH101001R1644
4/62
MS497-63 1SAM580000R1007
2/23
NFZ22ES-23 1SBH136004R2322
6/69
NS44E-20 1SBH101001R2044
4/62
MS497-75 1SAM580000R1008
2/23
NFZ31E-20 1SBH136001R2031
5/305
NS44E-26 1SBH101001R2644
4/62
MS497-90 1SAM580000R1009
2/23
NFZ31E-21 1SBH136001R2131
5/305
NS44E-28 1SBH101001R2844
4/62
MSAH1 1SAM201909R1021
2/38
NFZ31E-22 1SBH136001R2231
5/305
NS44ES-16 1SBH101004R1644
6/22
MSH-AR 1SAM201920R1000
2/38
NFZ31E-23 1SBH136001R2331
5/305
NS44ES-20 1SBH101004R2044
6/22
MSHD-LB 1SAM201920R1001
2/38
NFZ31ES-20 1SBH136004R2031
6/69
NS44ES-26 1SBH101004R2644
6/22
MSHD-LTB 1SAM201920R1011
2/38
NFZ31ES-21 1SBH136004R2131
6/69
NS44ES-28 1SBH101004R2844
6/22
MSHD-LTY 1SAM201920R1012
2/38
NFZ31ES-22 1SBH136004R2231
6/69
NS53E-16 1SBH101001R1653
4/62
MSHD-LY 1SAM201920R1002
2/38
NFZ31ES-23 1SBH136004R2331
6/69
NS53E-20 1SBH101001R2053
4/62
MSMN 1SAM101923R0002
2/38
NFZ33/11-20 1SBH136001R2039
5/309
NS53E-26 1SBH101001R2653
4/62
MSMNO 1SAM101923R0012
2/38
NFZ33/11-21 1SBH136001R2139
5/309
NS53E-28 1SBH101001R2853
4/62
NF22E-12 1SBH137001R1222
5/304
NFZ33/11-22 1SBH136001R2239
5/309
NS53ES-16 1SBH101004R1653
6/22
NF22E-13 1SBH137001R1322
5/304
NFZ33/11-23 1SBH136001R2339
5/309
NS53ES-20 1SBH101004R2053
6/22
NF22E-14 1SBH137001R1422
5/304
NFZ40E-20 1SBH136001R2040
5/305
NS53ES-26 1SBH101004R2653
6/22
NF22E-41 1SBH137001R4122
5/304
NFZ40E-21 1SBH136001R2140
5/305
NS53ES-28 1SBH101004R2853
6/22
NF22ES-12 1SBH137004R1222
6/68
NFZ40E-22 1SBH136001R2240
5/305
NS62E-16 1SBH101001R1662
4/62
NF22ES-13 1SBH137004R1322
6/68
NFZ40E-23 1SBH136001R2340
5/305
NS62E-20 1SBH101001R2062
4/62
NF22ES-14 1SBH137004R1422
6/68
NFZ40ES-20 1SBH136004R2040
6/69
NS62E-26 1SBH101001R2662
4/62
NF22ES-41 1SBH137004R4122
6/68
NFZ40ES-21 1SBH136004R2140
6/69
NS62E-28 1SBH101001R2862
4/62
NF31E-12 1SBH137001R1231
5/304
NFZ40ES-22 1SBH136004R2240
6/69
NS62ES-16 1SBH101004R1662
6/22
NF31E-13 1SBH137001R1331
5/304
NFZ40ES-23 1SBH136004R2340
6/69
NS62ES-20 1SBH101004R2062
6/22
NF31E-14 1SBH137001R1431
5/304
NFZ44E-20 1SBH136001R2044
5/309
NS62ES-26 1SBH101004R2662
6/22
NF31E-41 1SBH137001R4131
5/304
NFZ44E-21 1SBH136001R2144
5/309
NS62ES-28 1SBH101004R2862
6/22
NF31ES-12 1SBH137004R1231
6/68
NFZ44E-22 1SBH136001R2244
5/309
NS71E-16 1SBH101001R1671
4/62
NF31ES-13 1SBH137004R1331
6/68
NFZ44E-23 1SBH136001R2344
5/309
NS71E-20 1SBH101001R2071
4/62
NF31ES-14 1SBH137004R1431
6/68
NFZ44ES-20 1SBH136004R2044
6/71
NS71E-26 1SBH101001R2671
4/62
NF31ES-41 1SBH137004R4131
6/68
NFZ44ES-21 1SBH136004R2144
6/71
NS71E-28 1SBH101001R2871
4/62
NF33/11-12 1SBH137001R1239
5/308
NFZ44ES-22 1SBH136004R2244
6/71
NS71ES-16 1SBH101004R1671
6/22
NF33/11-13 1SBH137001R1339
5/308
NFZ44ES-23 1SBH136004R2344
6/71
NS71ES-20 1SBH101004R2071
6/22
NF33/11-14 1SBH137001R1439
5/308
NFZ51/11-20 1SBH136001R2059
5/309
NS71ES-26 1SBH101004R2671
6/22
13/16 | ABB
Index
Type classification
Type
Order code
Page
Type
Order code
Page
Type
Order code
Page
PR400-2 1SFN095700R1002
5/354
NS71ES-28 1SBH101004R2871
6/22
T16-1.3 1SAZ711201R1025
7/4
PR460-1 1SFN095700R1000
5/354
NS80E-16 1SBH101001R1680
4/62
T16-1.7 1SAZ711201R1028
7/4
PR460-2 1SFN095700R1001
5/354
NS80E-20 1SBH101001R2080
4/62
T16-10 1SAZ711201R1043
7/4
PR580-2 1SFN096100R1002
5/354
NS80E-26 1SBH101001R2680
4/62
T16-13 1SAZ711201R1045
7/4
PR750-1 1SFN096100R1000
5/354
NS80E-28 1SBH101001R2880
4/62
T16-16 1SAZ711201R1047
7/4
PR750-2 1SFN096100R1001
5/354
NS80ES-16 1SBH101004R1680
6/22
T16-2.3 1SAZ711201R1031
7/4
PS1-2-0-65 1SAM201906R1102
2/20
NS80ES-20 1SBH101004R2080
6/22
T16-3.1 1SAZ711201R1033
7/4
PS1-2-1-65 1SAM201906R1112
2/20
NS80ES-26 1SBH101004R2680
6/22
T16-4.2 1SAZ711201R1035
7/4
PS1-2-2-65 1SAM201906R1122
2/20
NS80ES-28 1SBH101004R2880
6/22
T16-5.7 1SAZ711201R1038
7/4
PS1-3-0-100 1SAM201916R1103
2/20
NSL22E-81 1SBH103001R8122
4/63
T16-7.6 1SAZ711201R1040
7/4
PS1-3-0-65 1SAM201906R1103
2/20
NSL22E-83 1SBH103001R8322
4/63
TA200DU-110 1SAZ421201R1002
7/24
PS1-3-1-100 1SAM201916R1113
2/20
NSL22E-86 1SBH103001R8622
4/63
TA200DU-135 1SAZ421201R1003
7/24
PS1-3-1-65 1SAM201906R1113
2/20
NSL22E-88 1SBH103001R8822
4/63
TA200DU-150 1SAZ421201R1004
7/24
PS1-3-2-100 1SAM201916R1123
2/20
NSL22ES-81 1SBH103004R8122
6/23
TA200DU-175 1SAZ421201R1005
7/24
PS1-3-2-65 1SAM201906R1123
2/20
NSL22ES-83 1SBH103004R8322
6/23
TA200DU-200 1SAZ421201R1006
7/24
PS1-4-0-100 1SAM201916R1104
2/20
NSL22ES-86 1SBH103004R8622
6/23
TA200DU-90 1SAZ421201R1001
7/24
PS1-4-0-65 1SAM201906R1104
2/20
NSL22ES-88 1SBH103004R8822
6/23
TB450 1SAM401910R1001
2/35
PS1-4-1-100 1SAM201916R1114
2/20
NSL31E-81 1SBH103001R8131
4/63
TBC7-22-00-55 GJL1313561R5005
3/14
PS1-4-1-65 1SAM201906R1114
2/20
NSL31E-83 1SBH103001R8331
4/63
TBC7-22-00-62 GJL1313561R6002
3/14
PS1-4-2-65 1SAM201906R1124
2/20
NSL31E-86 1SBH103001R8631
4/63
TBC7-22-00-68 GJL1313561R6008
3/14
PS1-5-0-100 1SAM201916R1105
2/20
NSL31E-88 1SBH103001R8831
4/63
TBC7-30-01-51 GJL1313061R5011
3/11
PS1-5-0-65 1SAM201906R1105
2/20
NSL31ES-81 1SBH103004R8131
6/23
TBC7-30-01-55 GJL1313061R5015
3/11
PS1-5-1-100 1SAM201916R1115
2/20
NSL31ES-83 1SBH103004R8331
6/23
TBC7-30-01-62 GJL1313061R6012
3/11
PS1-5-1-65 1SAM201906R1115
2/20
NSL31ES-86 1SBH103004R8631
6/23
TBC7-30-01-68 GJL1313061R6018
3/11
PS1-5-2-65 1SAM201906R1125
2/20
NSL31ES-88 1SBH103004R8831
6/23
TBC7-30-10-51 GJL1313061R5101
3/11
PS4-2-0 1SAM401911R1001
2/35
NSL40E-81 1SBH103001R8140
4/63
TBC7-30-10-55 GJL1313061R5105
3/11
PS4-2-2 1SAM401911R1004
2/35
NSL40E-83 1SBH103001R8340
4/63
TBC7-30-10-62 GJL1313061R6102
3/11
PS4-3-0 1SAM401911R1002
2/35
NSL40E-86 1SBH103001R8640
4/63
TBC7-30-10-68 GJL1313061R6108
3/11
PS4-3-2 1SAM401911R1005
2/35
NSL40E-88 1SBH103001R8840
4/63
TBC7-31-00-55 GJL1313461R5005
3/14
PS4-4-0 1SAM401911R1003
2/35
NSL40ES-81 1SBH103004R8140
6/23
TBC7-31-00-62 GJL1313461R6002
3/14
PS4-4-2 1SAM401911R1006
2/35
NSL40ES-83 1SBH103004R8340
6/23
TBC7-31-00-68 GJL1313461R6008
3/14
RA5-1 1SBN060300R1000
5/374
NSL40ES-86 1SBH103004R8640
6/23
TEF3-OFF 1SBN021014R1000
4/37
1SBN060300T1000
5/374
NSL40ES-88 1SBH103004R8840
6/23
TEF3-ON 1SBN021012R1000
4/37
RC5-1/133 1SBN050100R1001
4/37
NSL44E-81 1SBH103001R8144
4/63
TEF4-OFF 1SBN020114R1000
5/87
RC5-1/250 1SBN050100R1002
4/37
NSL44E-83 1SBH103001R8344
4/63
TEF4-ON 1SBN020112R1000
5/87
RC5-1/440 1SBN050100R1003
4/37
NSL44E-86 1SBH103001R8644
4/63
TEF4S-OFF 1SBN020115R1000
6/51
RC5-1/50 1SBN050100R1000
4/37
NSL44E-88 1SBH103001R8844
4/63
TEF4S-ON 1SBN020113R1000
6/51
RC5-2/133 1SBN050200R1001
5/372
NSL44ES-81 1SBH103004R8144
6/23
TEF5-OFF 1SBN020314R1000
5/365
RC5-2/250 1SBN050200R1002
5/372
NSL44ES-83 1SBH103004R8344
6/23
TEF5-ON 1SBN020312R1000
5/365
RC5-2/440 1SBN050200R1003
5/372
NSL44ES-86 1SBH103004R8644
6/23
TF140DU-110 1SAZ431201R1002
7/20
RC5-2/50 1SBN050200R1000
5/372
NSL44ES-88 1SBH103004R8844
6/23
TF140DU-135 1SAZ431201R1003
7/20
RT5/150 1SBN050020R1003
4/37
NSL53E-81 1SBH103001R8153
4/63
TF140DU-142 1SAZ431201R1004
7/20
RT5/264 1SBN050020R1004
4/37
NSL53E-83 1SBH103001R8353
4/63
TF140DU-90 1SAZ431201R1001
7/20
RT5/32 1SBN050020R1000
4/37
NSL53E-86 1SBH103001R8653
4/63
TF42-0.13 1SAZ721201R1005
7/8
RT5/65 1SBN050020R1001
4/37
NSL53E-88 1SBH103001R8853
4/63
TF42-0.17 1SAZ721201R1008
7/8
RT5/90 1SBN050020R1002
4/37
NSL53ES-81 1SBH103004R8153
6/23
TF42-0.23 1SAZ721201R1009
7/8
RV5/133 1SBN050010R1001
4/37
NSL53ES-83 1SBH103004R8353
6/23
TF42-0.31 1SAZ721201R1013
7/8
RV5/250 1SBN050010R1002
4/37
NSL53ES-86 1SBH103004R8653
6/23
TF42-0.41 1SAZ721201R1014
7/8
RV5/440 1SBN050010R1003
4/37
NSL53ES-88 1SBH103004R8853
6/23
TF42-0.55 1SAZ721201R1017
7/8
RV5/50 1SBN050010R1000
4/37
NSL62E-81 1SBH103001R8162
4/63
TF42-0.74 1SAZ721201R1021
7/8
RV-BC6/250 GHV2501903R0002
3/39
NSL62E-83 1SBH103001R8362
4/63
TF42-1.0 1SAZ721201R1023
7/8
RV-BC6/380 GHV2501904R0002
3/39
NSL62E-86 1SBH103001R8662
4/63
TF42-1.3 1SAZ721201R1025
7/8
RV-BC6/60 GHV2501902R0002
3/39
NSL62E-88 1SBH103001R8862
4/63
TF42-1.7 1SAZ721201R1028
7/8
RV-BC6-F/250 GHV2501903R0003
3/39
NSL62ES-81 1SBH103004R8162
6/23
TF42-10 1SAZ721201R1043
7/8
RV-BC6-F/380 GHV2501904R0003
3/39
NSL62ES-83 1SBH103004R8362
6/23
TF42-13 1SAZ721201R1045
7/8
RV-BC6-F/60 GHV2501902R0003
3/39
NSL62ES-86 1SBH103004R8662
6/23
TF42-16 1SAZ721201R1047
7/8
S1-M1-25 1SAM201907R1101
2/20
NSL62ES-88 1SBH103004R8862
6/23
TF42-2.3 1SAZ721201R1031
7/8
S1-M2-25 1SAM201907R1102
2/20
NSL71E-81 1SBH103001R8171
4/63
TF42-20 1SAZ721201R1049
7/8
S1-M3-25 1SAM201907R1103
2/20
NSL71E-83 1SBH103001R8371
4/63
TF42-24 1SAZ721201R1051
7/8
S1-M3-35 1SAM201913R1103
2/20
NSL71E-86 1SBH103001R8671
4/63
TF42-29 1SAZ721201R1052
7/8
S1-PB1-25 1SAM201914R1002
2/20
NSL71E-88 1SBH103001R8871
4/63
TF42-3.1 1SAZ721201R1033
7/8
S4-M1 1SAM401911R1007
2/35
NSL71ES-81 1SBH103004R8171
6/23
TF42-35 1SAZ721201R1053
7/8
S801S-SCL100-SR 2CCS801901R0639 11/2
NSL71ES-83 1SBH103004R8371
6/23
TF42-38 1SAZ721201R1055
7/8
S801S-SCL32-SR 2CCS801901R0539
11/2
NSL71ES-86 1SBH103004R8671
6/23
TF42-4.2 1SAZ721201R1035
7/8
S801S-SCL63-SR 2CCS801901R0599
11/2
NSL71ES-88 1SBH103004R8871
6/23
TF42-5.7 1SAZ721201R1038
7/8
S802S-SCL100-SR 2CCS802901R0639 11/2
NSL80E-81 1SBH103001R8180
4/63
TF42-7.6 1SAZ721201R1040
7/8
S802S-SCL32-SR 2CCS802901R0539
11/2
NSL80E-83 1SBH103001R8380
4/63
TF65-28 1SAZ811201R1001
7/12
S802S-SCL63-SR 2CCS802901R0599
11/2
NSL80E-86 1SBH103001R8680
4/63
TF65-33 1SAZ811201R1002
7/12
S803S-SCL100-SR 2CCS803901R0639 11/2
NSL80E-88 1SBH103001R8880
4/63
TF65-40 1SAZ811201R1003
7/12
S803S-SCL32-SR 2CCS803901R0539
11/2
NSL80ES-81 1SBH103004R8180
6/23
TF65-47 1SAZ811201R1004
7/12
S803S-SCL63-SR 2CCS803901R0599
11/2
NSL80ES-83 1SBH103004R8380
6/23
TF65-53 1SAZ811201R1005
7/12
S803W-SCL100-SR 2CCS803917R0639 11/2
NSL80ES-86 1SBH103004R8680
6/23
TF65-60 1SAZ811201R1006
7/12
S803W-SCL32-SR 2CCS803917R0539
11/2
NSL80ES-88 1SBH103004R8880
6/23
TF65-67 1SAZ811201R1007
7/12
S803W-SCL63-SR 2CCS803917R0599
11/2
OESA460H/OESA400 1SFN085709R1000 5/352
TF96-51 1SAZ911201R1001
7/16
SA1 GJF1101903R0001
2/20
OXS6X105 1SCA108043R1001
2/38
TF96-60 1SAZ911201R1002
7/16
SA2 GJF1101903R0002
2/20
OXS6X130 1SCA101655R1001
2/38
TF96-68 1SAZ911201R1003
7/16
SA3 GJF1101903R0003
2/20
OXS6X180 1SCA101659R1001
2/38
TF96-78 1SAZ911201R1004
7/16
SK1-02 1SAM201903R1003
2/15
OXS6X85 1SCA101647R1001
2/38
TF96-87 1SAZ911201R1005
7/16
SK1-11 1SAM201903R1001
2/15
PB1-1-32 1SAM201914R1001
2/20
TF96-96 1SAZ911201R1006
7/16
SK1-20 1SAM201903R1002
2/15
PN460-11 1SFN095705R1000
5/353
TKC6-22Z-51 GJH1213061R5221
3/18
SK4-11 1SAM401904R1001
2/32
PN460-21 1SFN095701R1000
5/353
TKC6-22Z-55 GJH1213061R5225
3/18
SPRC 1
1SNA360010R1500
4/82
PN460-41 1SFN095703R1000
5/353
TKC6-22Z-62 GJH1213061R6222
3/18
T16-0.13 1SAZ711201R1005
7/4
PN750-11 1SFN096105R1000
5/353
TKC6-22Z-68 GJH1213061R6228
3/18
T16-0.17 1SAZ711201R1008
7/4
PN750-21 1SFN096101R1000
5/353
TKC6-31Z-51 GJH1213061R5311
3/18
T16-0.23 1SAZ711201R1009
7/4
PN750-41 1SFN096103R1000
5/353
TKC6-31Z-55 GJH1213061R5315
3/18
T16-0.31 1SAZ711201R1013
7/4
PR146-1 1SFN094200R1000
5/354
TKC6-31Z-62 GJH1213061R6312
3/18
T16-0.41 1SAZ711201R1014
7/4
PR185-2 1SFN095100R1001
5/354
TKC6-31Z-68 GJH1213061R6318
3/18
T16-0.55 1SAZ711201R1017
7/4
PR210-1 1SFN094900R1000
5/354
TKC6-40E-51 GJH1213061R5401
3/18
T16-0.74 1SAZ711201R1021
7/4
PR300-1 1SFN095300R1000
5/354
TKC6-40E-55 GJH1213061R5405
3/18
T16-1.0 1SAZ711201R1023
7/4
PR300-2 1SFN095300R1001
5/354
TKC6-40E-62 GJH1213061R6402
3/18
Index
13
ABB | 13/17
Index
Type classification
13
Order code
Page
Type
Order code
Page
Type
Order code
Page
TKC6-40E-68 GJH1213061R6408
3/18
1SBL351024R8400
5/267
VAS16EM-16M 1SBK123600M1600
4/46
UA110-30-00 1SFL451022R8000
5/279
1SBL351024R8500
5/267
VAS16EM-20M 1SBK123600M2000
4/46
1SFL451022R8100
5/279
1SBL351024R8600
5/267
VAS16EM-26M 1SBK123600M2600
4/46
1SFL451022R8300
5/279
1SBL351024R8800
5/267
VAS16EM-28M 1SBK123600M2800
4/46
1SFL451022R8400
5/279
UA50-30-11 1SBL351022R8011
5/278
VAS16SEM-16M 1SBK123800M1600
4/46
1SFL451022R8500
5/279
1SBL351022R8111
5/278
VAS16SEM-20M 1SBK123800M2000
4/46
1SFL451022R8600
5/279
1SBL351022R8311
5/278
VAS16SEM-26M 1SBK123800M2600
4/46
1SFL451022R8800
5/279
1SBL351022R8411
5/278
VAS16SEM-28M 1SBK123800M2800
4/46
UA110-30-00RA 1SFL451024R8000
5/268
1SBL351022R8511
5/278
VASL09EM-81M 1SBK103700M8100
4/47
1SFL451024R8100
5/268
1SBL351022R8611
5/278
VASL09EM-83M 1SBK103700M8300
4/47
1SFL451024R8300
5/268
1SBL351022R8811
5/278
VASL09EM-86M 1SBK103700M8600
4/47
1SFL451024R8400
5/268
UA63-30-00 1SBL371022R8000
5/277
VASL09EM-88M 1SBK103700M8800
4/47
1SFL451024R8500
5/268
1SBL371022R8100
5/277
VASL09SEM-81M 1SBK103900M8100
4/47
1SFL451024R8600
5/268
1SBL371022R8300
5/277
VASL09SEM-83M 1SBK103900M8300
4/47
1SFL451024R8800
5/268
1SBL371022R8400
5/277
VASL09SEM-86M 1SBK103900M8600
4/47
UA110-30-11 1SFL451022R8011
5/280
1SBL371022R8500
5/277
VASL09SEM-88M 1SBK103900M8800
4/47
1SFL451022R8111
5/280
1SBL371022R8600
5/277
VASL12EM-81M 1SBK113700M8100
4/47
1SFL451022R8311
5/280
1SBL371022R8800
5/277
VASL12EM-83M 1SBK113700M8300
4/47
1SFL451022R8411
5/280
UA63-30-00RA 1SBL371024R8000
5/267
VASL12EM-86M 1SBK113700M8600
4/47
1SFL451022R8511
5/280
1SBL371024R8100
5/267
VASL12EM-88M 1SBK113700M8800
4/47
1SFL451022R8611
5/280
1SBL371024R8300
5/267
VASL12SEM-81M 1SBK113900M8100
4/47
1SFL451022R8811
5/280
1SBL371024R8400
5/267
VASL12SEM-83M 1SBK113900M8300
4/47
UA1-110 1SAM201904R1004
2/16
1SBL371024R8500
5/267
VASL12SEM-86M 1SBK113900M8600
4/47
UA1-20 1SAM201904R1010
2/16
1SBL371024R8600
5/267
VASL12SEM-88M 1SBK113900M8800
4/47
UA1-208 1SAM201904R1008
2/16
1SBL371024R8800
5/267
VASL16EM-81M 1SBK123700M8100
4/47
UA1-230 1SAM201904R1005
2/16
UA63-30-11 1SBL371022R8011
5/278
VASL16EM-83M 1SBK123700M8300
4/47
UA1-24 1SAM201904R1001
2/16
1SBL371022R8111
5/278
VASL16EM-86M 1SBK123700M8600
4/47
UA1-400 1SAM201904R1006
2/16
1SBL371022R8311
5/278
VASL16EM-88M 1SBK123700M8800
4/47
UA1-415 1SAM201904R1007
2/16
1SBL371022R8411
5/278
VASL16SEM-81M 1SBK123900M8100
4/47
UA1-48 1SAM201904R1002
2/16
1SBL371022R8511
5/278
VASL16SEM-83M 1SBK123900M8300
4/47
UA1-575 1SAM201904R1009
2/16
1SBL371022R8611
5/278
VASL16SEM-86M 1SBK123900M8600
4/47
UA1-60 1SAM201904R1003
2/16
1SBL371022R8811
5/278
VASL16SEM-88M 1SBK123900M8800
4/47
UA16-30-10 1SBL181022R8010
5/276
UA75-30-00 1SBL411022R8000
5/277
VB6-30-01-01 GJL1211901R0011
3/6
1SBL181022R8110
5/276
1SBL411022R8100
5/277
VB6-30-01-02 GJL1211901R0012
3/6
1SBL181022R8310
5/276
1SBL411022R8300
5/277
VB6-30-01-03 GJL1211901R0013
3/6
1SBL181022R8410
5/276
1SBL411022R8400
5/277
VB6-30-01-80 GJL1211901R8010
3/6
1SBL181022R8510
5/276
1SBL411022R8500
5/277
VB6-30-01-84 GJL1211901R8014
3/6
1SBL181022R8610
5/276
1SBL411022R8600
5/277
VB6-30-01-85 GJL1211901R8015
3/6
1SBL181022R8810
5/276
1SBL411022R8800
5/277
VB6-30-01-P-01 GJL1211909R0011
3/21
UA16-30-10RA 1SBL181024R8010
5/266
UA75-30-00RA 1SBL411024R8000
5/267
VB6-30-01-P-02 GJL1211909R0012
3/21
1SBL181024R8110
5/266
1SBL411024R8100
5/267
VB6-30-01-P-03 GJL1211909R0013
3/21
1SBL181024R8310
5/266
1SBL411024R8300
5/267
VB6-30-01-P-80 GJL1211909R8010
3/21
1SBL181024R8410
5/266
1SBL411024R8400
5/267
VB6-30-01-P-84 GJL1211909R8014
3/21
1SBL181024R8510
5/266
1SBL411024R8500
5/267
VB6-30-01-P-85 GJL1211909R8015
3/21
1SBL181024R8610
5/266
1SBL411024R8600
5/267
VB6-30-10-01 GJL1211901R0101
3/6
1SBL181024R8810
5/266
1SBL411024R8800
5/267
VB6-30-10-02 GJL1211901R0102
3/6
UA26-30-10 1SBL241022R8010
5/276
UA75-30-11 1SBL411022R8011
5/278
VB6-30-10-03 GJL1211901R0103
3/6
1SBL241022R8110
5/276
1SBL411022R8111
5/278
VB6-30-10-80 GJL1211901R8100
3/6
1SBL241022R8310
5/276
1SBL411022R8311
5/278
VB6-30-10-84 GJL1211901R8104
3/6
1SBL241022R8410
5/276
1SBL411022R8411
5/278
VB6-30-10-85 GJL1211901R8105
3/6
1SBL241022R8510
5/276
1SBL411022R8511
5/278
VB6-30-10-P-01 GJL1211909R0101
3/21
1SBL241022R8610
5/276
1SBL411022R8611
5/278
VB6-30-10-P-02 GJL1211909R0102
3/21
1SBL241022R8810
5/276
1SBL411022R8811
5/278
VB6-30-10-P-03 GJL1211909R0103
3/21
UA26-30-10RA 1SBL241024R8010
5/266
UA95-30-00 1SFL431022R8000
5/279
VB6-30-10-P-80 GJL1211909R8100
3/21
1SBL241024R8110
5/266
1SFL431022R8100
5/279
VB6-30-10-P-84 GJL1211909R8104
3/21
1SBL241024R8310
5/266
1SFL431022R8300
5/279
VB6-30-10-P-85 GJL1211909R8105
3/21
1SBL241024R8410
5/266
1SFL431022R8400
5/279
VB6A-30-01-01 GJL1211911R0011
3/8
1SBL241024R8510
5/266
1SFL431022R8500
5/279
VB6A-30-01-02 GJL1211911R0012
3/8
1SBL241024R8610
5/266
1SFL431022R8600
5/279
VB6A-30-01-03 GJL1211911R0013
3/8
1SBL241024R8810
5/266
1SFL431022R8800
5/279
VB6A-30-01-80 GJL1211911R8010
3/8
UA30-30-10 1SBL281022R8010
5/276
UA95-30-00RA 1SFL431024R8000
5/268
VB6A-30-01-84 GJL1211911R8014
3/8
1SBL281022R8110
5/276
1SFL431024R8100
5/268
VB6A-30-01-85 GJL1211911R8015
3/8
1SBL281022R8310
5/276
1SFL431024R8300
5/268
VB6A-30-01-P-01 GJL1211919R0011
3/23
1SBL281022R8410
5/276
1SFL431024R8400
5/268
VB6A-30-01-P-02 GJL1211919R0012
3/23
1SBL281022R8510
5/276
1SFL431024R8500
5/268
VB6A-30-01-P-03 GJL1211919R0013
3/23
1SBL281022R8610
5/276
1SFL431024R8600
5/268
VB6A-30-01-P-80 GJL1211919R8010
3/23
1SBL281022R8810
5/276
1SFL431024R8800
5/268
VB6A-30-01-P-84 GJL1211919R8014
3/23
UA30-30-10RA 1SBL281024R8010
5/266
UA95-30-11 1SFL431022R8011
5/280
VB6A-30-01-P-85 GJL1211919R8015
3/23
1SBL281024R8110
5/266
1SFL431022R8111
5/280
VB6A-30-10-01 GJL1211911R0101
3/8
1SBL281024R8310
5/266
1SFL431022R8311
5/280
VB6A-30-10-02 GJL1211911R0102
3/8
1SBL281024R8410
5/266
1SFL431022R8411
5/280
VB6A-30-10-03 GJL1211911R0103
3/8
1SBL281024R8510
5/266
1SFL431022R8511
5/280
VB6A-30-10-80 GJL1211911R8100
3/8
1SBL281024R8610
5/266
1SFL431022R8611
5/280
VB6A-30-10-84 GJL1211911R8104
3/8
1SBL281024R8810
5/266
1SFL431022R8811
5/280
VB6A-30-10-85 GJL1211911R8105
3/8
UA4-110 1SAM401905R1001
2/32
VAS09EM-16M 1SBK103600M1600
4/46
VB6A-30-10-P-01 GJL1211919R0101
3/23
UA4-230 1SAM401905R1002
2/32
VAS09EM-20M 1SBK103600M2000
4/46
VB6A-30-10-P-02 GJL1211919R0102
3/23
UA4-24 1SAM401905R1004
2/32
VAS09EM-26M 1SBK103600M2600
4/46
VB6A-30-10-P-03 GJL1211919R0103
3/23
UA4-400 1SAM401905R1003
2/32
VAS09EM-28M 1SBK103600M2800
4/46
VB6A-30-10-P-80 GJL1211919R8100
3/23
UA4-HK-230 1SAM401906R1001
2/32
VAS09SEM-16M 1SBK103800M1600
4/46
VB6A-30-10-P-84 GJL1211919R8104
3/23
UA4-HK-400 1SAM401906R1002
2/32
VAS09SEM-20M 1SBK103800M2000
4/46
VB6A-30-10-P-85 GJL1211919R8105
3/23
UA50-30-00 1SBL351022R8000
5/277
VAS09SEM-26M 1SBK103800M2600
4/46
VB7-30-01-01 GJL1311901R0011
3/6
1SBL351022R8100
5/277
VAS09SEM-28M 1SBK103800M2800
4/46
VB7-30-01-02 GJL1311901R0012
3/6
1SBL351022R8300
5/277
VAS12EM-16M 1SBK113600M1600
4/46
VB7-30-01-03 GJL1311901R0013
3/6
1SBL351022R8400
5/277
VAS12EM-20M 1SBK113600M2000
4/46
VB7-30-01-80 GJL1311901R8010
3/6
1SBL351022R8500
5/277
VAS12EM-26M 1SBK113600M2600
4/46
VB7-30-01-84 GJL1311901R8014
3/6
1SBL351022R8600
5/277
VAS12EM-28M 1SBK113600M2800
4/46
VB7-30-01-85 GJL1311901R8015
3/6
1SBL351022R8800
5/277
VAS12SEM-16M 1SBK113800M1600
4/46
VB7-30-01-F-01 GJL1311903R0011
3/31
UA50-30-00RA 1SBL351024R8000
5/267
VAS12SEM-20M 1SBK113800M2000
4/46
VB7-30-01-F-02 GJL1311903R0012
3/31
1SBL351024R8100
5/267
VAS12SEM-26M 1SBK113800M2600
4/46
VB7-30-01-F-03 GJL1311903R0013
3/31
1SBL351024R8300
5/267
VAS12SEM-28M 1SBK113800M2800
4/46
VB7-30-01-F-80 GJL1311903R8010
3/31
13/18 | ABB
Index
Type
Index
Type classification
Order code
Page
VB7-30-01-F-84 GJL1311903R8014
3/31
VB7-30-01-F-85 GJL1311903R8015
3/31
VB7-30-01-P-01 GJL1311909R0011
3/21
VB7-30-01-P-02 GJL1311909R0012
3/21
VB7-30-01-P-03 GJL1311909R0013
3/21
VB7-30-01-P-80 GJL1311909R8010
3/21
VB7-30-01-P-84 GJL1311909R8014
3/21
VB7-30-01-P-85 GJL1311909R8015
3/21
VB7-30-10-01 GJL1311901R0101
3/6
VB7-30-10-02 GJL1311901R0102
3/6
VB7-30-10-03 GJL1311901R0103
3/6
VB7-30-10-80 GJL1311901R8100
3/6
VB7-30-10-84 GJL1311901R8104
3/6
VB7-30-10-85 GJL1311901R8105
3/6
VB7-30-10-F-01 GJL1311903R0101
3/31
VB7-30-10-F-02 GJL1311903R0102
3/31
VB7-30-10-F-03 GJL1311903R0103
3/31
VB7-30-10-F-80 GJL1311903R8100
3/31
VB7-30-10-F-84 GJL1311903R8104
3/31
VB7-30-10-F-85 GJL1311903R8105
3/31
VB7-30-10-P-01 GJL1311909R0101
3/21
VB7-30-10-P-02 GJL1311909R0102
3/21
VB7-30-10-P-03 GJL1311909R0103
3/21
VB7-30-10-P-80 GJL1311909R8100
3/21
VB7-30-10-P-84 GJL1311909R8104
3/21
VB7-30-10-P-85 GJL1311909R8105
3/21
VB7A-30-01-01 GJL1311911R0011
3/8
VB7A-30-01-02 GJL1311911R0012
3/8
VB7A-30-01-03 GJL1311911R0013
3/8
VB7A-30-01-80 GJL1311911R8010
3/8
VB7A-30-01-84 GJL1311911R8014
3/8
VB7A-30-01-85 GJL1311911R8015
3/8
VB7A-30-01-F-01 GJL1311913R0011
3/33
VB7A-30-01-F-02 GJL1311913R0012
3/33
VB7A-30-01-F-03 GJL1311913R0013
3/33
VB7A-30-01-F-80 GJL1311913R8010
3/33
VB7A-30-01-F-84 GJL1311913R8014
3/33
VB7A-30-01-F-85 GJL1311913R8015
3/33
VB7A-30-01-P-01 GJL1311919R0011
3/23
VB7A-30-01-P-02 GJL1311919R0012
3/23
VB7A-30-01-P-03 GJL1311919R0013
3/23
VB7A-30-01-P-80 GJL1311919R8010
3/23
VB7A-30-01-P-84 GJL1311919R8014
3/23
VB7A-30-01-P-85 GJL1311919R8015
3/23
VB7A-30-10-01 GJL1311911R0101
3/8
VB7A-30-10-02 GJL1311911R0102
3/8
VB7A-30-10-03 GJL1311911R0103
3/8
VB7A-30-10-80 GJL1311911R8100
3/8
VB7A-30-10-84 GJL1311911R8104
3/8
VB7A-30-10-85 GJL1311911R8105
3/8
VB7A-30-10-F-01 GJL1311913R0101
3/33
VB7A-30-10-F-02 GJL1311913R0102
3/33
VB7A-30-10-F-03 GJL1311913R0103
3/33
VB7A-30-10-F-80 GJL1311913R8100
3/33
VB7A-30-10-F-84 GJL1311913R8104
3/33
VB7A-30-10-F-85 GJL1311913R8105
3/33
VB7A-30-10-P-01 GJL1311919R0101
3/23
VB7A-30-10-P-02 GJL1311919R0102
3/23
VB7A-30-10-P-03 GJL1311919R0103
3/23
VB7A-30-10-P-80 GJL1311919R8100
3/23
VB7A-30-10-P-84 GJL1311919R8104
3/23
VB7A-30-10-P-85 GJL1311919R8105
3/23
VBC6-30-01-01 GJL1213901R0011
3/7
VBC6-30-01-03 GJL1213901R0013
3/7
VBC6-30-01-04 GJL1213901R0014
3/7
VBC6-30-01-05 GJL1213901R0015
3/7
VBC6-30-01-07 GJL1213901R0017
3/7
VBC6-30-01-16 GJL1213901R1016
3/7
VBC6-30-01-P-01 GJL1213909R0011
3/22
VBC6-30-01-P-03 GJL1213909R0013
3/22
VBC6-30-01-P-04 GJL1213909R0014
3/22
VBC6-30-01-P-05 GJL1213909R0015
3/22
VBC6-30-01-P-07 GJL1213909R0017
3/22
VBC6-30-06-P-06 GJL1213909R0016
3/22
VBC6-30-10-01 GJL1213901R0101
3/7
VBC6-30-10-03 GJL1213901R0103
3/7
VBC6-30-10-04 GJL1213901R0104
3/7
VBC6-30-10-05 GJL1213901R0105
3/7
VBC6-30-10-07 GJL1213901R0107
3/7
VBC6-30-10-16 GJL1213901R1106
3/7
VBC6-30-10-P-01 GJL1213909R0101
3/22
VBC6-30-10-P-03 GJL1213909R0103
3/22
VBC6-30-10-P-04 GJL1213909R0104
3/22
VBC6-30-10-P-05 GJL1213909R0105
3/22
VBC6-30-10-P-06 GJL1213909R0106
3/22
VBC6-30-10-P-07 GJL1213909R0107
3/22
VBC6A-30-01-01 GJL1213911R0011 3/9
VBC6A-30-01-03 GJL1213911R0013 3/9
VBC6A-30-01-04 GJL1213911R0014 3/9
VBC6A-30-01-05 GJL1213911R0015 3/9
Type
Order code
Page
Type
Order code
Page
VBC6A-30-01-07 GJL1213911R0017 3/9
VM96-4 1SBN033405T1000
5/87
VBC6A-30-01-16 GJL1213911R1016 3/9
WB75-A FPTN372726R1001
5/342
FPTN372726R1002
5/342
VBC6A-30-10-01 GJL1213911R0101 3/9
FPTN372726R1003
5/342
VBC6A-30-10-03 GJL1213911R0103 3/9
FPTN372726R1004
5/342
VBC6A-30-10-04 GJL1213911R0104 3/9
FPTN372726R1005
5/342
VBC6A-30-10-05 GJL1213911R0105 3/9
FPTN372726R1006
5/342
VBC6A-30-10-07 GJL1213911R0107 3/9
FPTN372726R1007
5/342
VBC6A-30-10-16 GJL1213911R1106 3/9
FPTN372726R1008
5/342
VBC7-30-01-01 GJL1313901R0011
3/7
WRB-1000 1SAZ701903R1013
7/51
VBC7-30-01-03 GJL1313901R0013
3/7
WRB-400 1SAZ701903R1011
7/51
VBC7-30-01-04 GJL1313901R0014
3/7
WRB-600 1SAZ701903R1012
7/51
VBC7-30-01-05 GJL1313901R0015
3/7
WRBG 1SAZ701903R1030
7/51
VBC7-30-01-07 GJL1313901R0017
3/7
WRH-F 1SAZ701903R1001
7/51
VBC7-30-01-16 GJL1313901R1016
3/7
ZA110 1SFN154310R8006
5/380
VBC7-30-01-F-01 GJL1313903R0011
3/32
1SFN154310R8106
5/380
VBC7-30-01-F-03 GJL1313903R0013
3/32
1SFN154310R8306
5/380
VBC7-30-01-F-04 GJL1313903R0014
3/32
1SFN154310R8406
5/380
VBC7-30-01-F-05 GJL1313903R0015
3/32
1SFN154310R8506
5/380
VBC7-30-01-F-07 GJL1313903R0017
3/32
1SFN154310R8606
5/380
VBC7-30-01-F-16 GJL1313903R1016
3/32
1SFN154310R8806
5/380
VBC7-30-01-P-01 GJL1313909R0011
3/22
ZA16 1SBN151410R8006
5/380
VBC7-30-01-P-03 GJL1313909R0013
3/22
1SBN151410R8106
5/380
VBC7-30-01-P-04 GJL1313909R0014
3/22
1SBN151410R8306
5/380
VBC7-30-01-P-05 GJL1313909R0015
3/22
1SBN151410R8406
5/380
VBC7-30-01-P-07 GJL1313909R0017
3/22
1SBN151410R8506
5/380
VBC7-30-01-P-16 GJL1313909R1016
3/22
1SBN151410R8606
5/380
VBC7-30-10-01 GJL1313901R0101
3/7
1SBN151410R8806
5/380
VBC7-30-10-03 GJL1313901R0103
3/7
ZA40 1SBN152410R8006
5/380
VBC7-30-10-04 GJL1313901R0104
3/7
1SBN152410R8106
5/380
VBC7-30-10-05 GJL1313901R0105
3/7
1SBN152410R8306
5/380
VBC7-30-10-07 GJL1313901R0107
3/7
1SBN152410R8406
5/380
VBC7-30-10-16 GJL1313901R1106
3/7
1SBN152410R8506
5/380
VBC7-30-10-F-01 GJL1313903R0101
3/32
1SBN152410R8606
5/380
VBC7-30-10-F-03 GJL1313903R0103
3/32
1SBN152410R8806
5/380
VBC7-30-10-F-04 GJL1313903R0104
3/32
ZA75 1SBN153510R8006
5/380
VBC7-30-10-F-05 GJL1313903R0105
3/32
1SBN153510R8106
5/380
VBC7-30-10-F-07 GJL1313903R0107
3/32
1SBN153510R8306
5/380
VBC7-30-10-F-16 GJL1313903R1106
3/32
1SBN153510R8406
5/380
VBC7-30-10-P-01 GJL1313909R0101
3/22
1SBN153510R8506
5/380
VBC7-30-10-P-03 GJL1313909R0103
3/22
1SBN153510R8606
5/380
VBC7-30-10-P-04 GJL1313909R0104
3/22
1SBN153510R8806
5/380
VBC7-30-10-P-05 GJL1313909R0105
3/22
ZAF1650 1SFN156570R7026
5/355
VBC7-30-10-P-07 GJL1313909R0107
3/22
ZAF2650 1SFN156670R7026
5/355
VBC7-30-10-P-16 GJL1313909R1106
3/22
ZAF460 1SFN155770R6806
5/355
VBC7A-30-01-01 GJL1313911R0011 3/9
1SFN155770R6906
5/355
VBC7A-30-01-03 GJL1313911R0013 3/9
1SFN155770R7006
5/355
VBC7A-30-01-04 GJL1313911R0014 3/9
1SFN155770R7106
5/355
VBC7A-30-01-05 GJL1313911R0015 3/9
ZAF750 1SFN156170R6806
5/355
VBC7A-30-01-07 GJL1313911R0017 3/9
1SFN156170R6906
5/355
VBC7A-30-01-16 GJL1313911R0016 3/9
1SFN156170R7006
5/355
VBC7A-30-01-F-01 GJL1313913R0011 3/34
1SFN156170R7106
5/355
VBC7A-30-01-F-03 GJL1313913R0013 3/34
ZL1250 1SFN166403R1000
5/355
VBC7A-30-01-F-04 GJL1313913R0014 3/34
ZL1350 1SFN166503R1000
5/355
VBC7A-30-01-F-05 GJL1313913R0015 3/34
ZL1650 1SFN166703R1000
5/355
VBC7A-30-01-F-07 GJL1313913R0017 3/34
ZL2050 1SFN167003R1000
5/355
VBC7A-30-01-F-16 GJL1313913R1016 3/34
ZL2650 1SFN166603R1000
5/355
VBC7A-30-01-P-01 GJL1313919R0011 3/24
ZL400 1SFN165703R1000
5/355
VBC7A-30-01-P-03 GJL1313919R0013 3/24
ZL460 1SFN165903R1000
5/355
VBC7A-30-01-P-04 GJL1313919R0014 3/24
ZL580 1SFN166103R1000
5/355
VBC7A-30-01-P-05 GJL1313919R0015 3/24
ZL750 1SFN166303R1000
5/355
VBC7A-30-01-P-07 GJL1313919R0017 3/24
ZLU110 1SFN164502R1000
5/380
VBC7A-30-01-P-16 GJL1313919R1016 3/24
ZLU50 1SBN163502R1000
5/380
VBC7A-30-10-01 GJL1313911R0101 3/9
ZLU63 1SBN163702R1000
5/380
VBC7A-30-10-03 GJL1313911R0103 3/9
ZLU75 1SBN164102R1000
5/380
VBC7A-30-10-04 GJL1313911R0104 3/9
ZLU95 1SFN164302R1000
5/380
VBC7A-30-10-05 GJL1313911R0105 3/9
ZP1650 1SFN166521R1070
5/355
VBC7A-30-10-07 GJL1313911R0107 3/9
ZP2650 1SFN166621R1070
5/355
VBC7A-30-10-16 GJL1313911R1106 3/9
ZW1650 1SFN166510R1000
5/355
VBC7A-30-10-F-01 GJL1313913R0101 3/34
ZW2650 1SFN166610R1000
5/355
VBC7A-30-10-F-03 GJL1313913R0103 3/34
ZW460 1SFN165710R1000
5/355
VBC7A-30-10-F-04 GJL1313913R0104 3/34
ZW750 1SFN166110R1000
5/355
VBC7A-30-10-F-05 GJL1313913R0105 3/34
VBC7A-30-10-F-07 GJL1313913R0107 3/34
VBC7A-30-10-F-16 GJL1313913R1106 3/34
VBC7A-30-10-P-01 GJL1313919R0101 3/24
VBC7A-30-10-P-03 GJL1313919R0103 3/24
VBC7A-30-10-P-04 GJL1313919R0104 3/24
VBC7A-30-10-P-05 GJL1313919R0105 3/24
VBC7A-30-10-P-07 GJL1313919R0107 3/24
VBC7A-30-10-P-16 GJL1313919R1106 3/24
VE5-2 1SBN030210R1000
5/368
VEM4 1SBN030111R1000
5/87
VM140/190 1SFN034403R1000
5/93
VM1650H 1SFN036503R1000
5/103
VM19 1SFN030300R1000
5/93
VM205/265 1SFN035203R1000
5/93
VM3 1SBN031005T1000
4/37
VM4 1SBN030105T1000
5/87
VM750H 1SFN035700R1000
5/103
VM750V 1SFN035701R1000
5/338
13
Index
Type
ABB | 13/19
Marketing material
www.abb.com/connecttocontrol
14
14/0 | ABB
Videos, prints, technical presentations and more
New
The AF range in your pocket
The eBinder gives you all the information you need
about the AF range.
Videos
Always updated
DemacLenko
Fabricant de canons à neige
Prolonger la saison
Distributeur
Réduire les stocks pour une meilleure productivité
1SFC101008L0301
Always available
1SFC101009L0301
ADL et Free Tech
Chauffage, Ventilation, Climatisation
Gagner en flexibilité pour plus de rentabilité
Le client
De nombreuses stations de ski d'Europe, d'Amérique du
Nord et d'Asie font confiance aux produits DemacLenko,
pour maintenir leur domaine skiable ouvert, que la neige
soit au rendez-vous ou non. La société offre des solutions
de gestion d'enneigement clés en main, du plan directeur
à la mise en service et la maintenance, en passant par les
infrastructures, les stations de pompage et le stockage de
l'eau. Ses canons à neige haute capacité peuvent générer
jusqu'à 105 m3 de neige par heure. Sauf en cas de coupure
de courant, bien entendu…
La solution d'ABB
DemacLenko s'est tourné vers ABB qui a pu trouver une
solution simple et efficace : remplacer la technologie
de contacteur classique par les contacteurs AF et leur
technologie avancée. Les résultats ont été immédiats. Les
pannes de contacteurs provoquées par les fluctuations de
Le client
tension ont pratiquement disparu. DemacLenko a en outre
Une belle réussite entraîne son lot de contraintes.
été impressionné par la qualité globale du produit, capable
Une clientèle plus nombreuse implique des stocks
de résister aux vibrations et au climat rigoureux, qui lui a
plus importants, des stocks plus importants impliquent
permis de réaliser des économies substantielles de temps
une logistique plus complexe et une logistique
et d'argent en termes d'entretien et de gestion. Autre
complexe engendre des délais de livraison et des coûts
avantage : un fabricant unique pour une gamme complète
supplémentaires. Les grands distributeurs de composants
d'équipements de démarrage moteur, ce qui simplifie la
électriques doivent stocker, distribuer et gérer des quantités
Le défi
maintenance et rationalise l'assemblage. Compatibles à
considérables de produits, notamment des dizaines de
C'est ce qui est arrivé bien trop souvent à la station de ski
la fois avec le courant AC et DC, sur réseau 50 ou 60 Hz,
milliers de contacteurs. Ils doivent ainsi composer avec
suédoise Funäsdal. Les conditions hivernales rigoureuses
les contacteurs AF peuvent être utilisés partout dans le
de fortes contraintes en termes d'espace et de logistique,
exercent évidemment des contraintes extrêmes sur les
monde. Leur plage de tension de commande plus large et
pour garantir une distribution rapide et efficace.
équipements d'enneigement : taux d'humidité élevé,
leurs valeurs d'accrochage et de décrochage plus franches
températures très basses et vibrations constantes. De plus,
garantissent un fonctionnement stable, même en cas de
Le défi
Le client
La solution
la longueur démesurée de certains câbles provoquait
des
fluctuations de tension.
Pour les distributeurs de produits électriques, les livraisons
La division Produits Basse Tension d'ABB dispose de plus
Les tableaux MNS d'ABB intègrent les technologies
fluctuations de tension endommageant les contacteurs,
doivent absolument être rapides et efficaces. Le succès est
de 40 ans
d'expérience
dans lacool,
construction
decontrôle.
tableaux
de tableaux les plus avancées du marché. La réduction des
ce qui engendrait des interruptions de service et
des arrêts
Pour rester
prenez le
source d'expansion, d'élargissement de la clientèle et de
basse tension. Une collaboration étroite avec un large éventail pertes d'énergie au sein des tableaux peut atteindre jusqu'à
coûteux pour la station. Que faire ?
de clients nous a permis
de concevoir une solution adaptée
28 %. Le contacteur AF, doté d'une bobine à commande croissance exponentielle des commandes. Une bonne chose,
ABB France
à tous les besoins.Division
Les nouveaux
tableaux
MNS, équipés
électronique, a démontré ses nombreux avantages par certes, mais également un défi à relever. La grande variété
Produits
Basse Tension
de la gamme de contacteurs
AF, permettent
une réduction
rapport aux technologies de contacteurs classiques. Ces de contacteurs disponibles implique en effet une gestion plus
Activité Basse
Tension
lourde, une logistique plus complexe et une augmentation
des pertes d'énergie pouvant atteindre 28 %, tout en offrant
avantages se traduisent par une fonctionnalité accrue
La solution d'ABB
des fonctionnalitéswww.abb.fr
et une durée de vie accrues.
du système MNS comparé aux technologies équivalentes des stocks. À ces nombreux produits viennent s’ajouter
SSAB cherchait à disposer d'une alimentation constante
disponibles aujourd'hui. La réduction des pertes d'énergieles accessoires supplémentaires, participant à leur tour à
et stable, sans devoir recourir à des systèmes d'alimentation
l’augmentation des stocks. Tous ces paramètres peuvent
Le défi
entraîne une prolongation de la durée de vie et de la
sans interruption (UPS) ou de secours sur batterie. Il arrivait
Dans l'industrie, le temps, c'est de l'argent. Les tendances
disponibilité de tous les composants du système MNS. compromettre l'efficacité des distributeurs en termes de
que les contacteurs classiques restent soudés en position
récentes sur le marché des tableaux basse tension indiquent
En résumé, le système MNS, équipé de contacteurs AF, délais de livraison. Les contacteurs AF d'ABB contribuent à
fermée suite à des coupures de tension résultant de l'instabilité
résoudre ce problème.
une orientation vers des complexes industriels plus vastes.
permet d'économiser de l'énergie, du temps, et donc,
du réseau électrique. Ne pouvant s'affranchir des coupures
L'efficacité énergétique est importante pour rester compétitif
de l'argent.
elles-mêmes, SSAB s'est tournée vers ABB, qui lui a
tout en se développant. Les clients d'ABB cherchent ainsi
proposé une solution en conformité avec la norme SEMI-F47
à améliorer l'efficacité énergétique de chaque aspect de leur
Pour mieux gérer votre énergie, prenez le contrôle.
d'immunité à ces coupures de tension : les contacteurs AF à
activité. ABB a identifié qu'il était possible d'économiser une
commande électronique.
quantité importante d'énergie, et donc d'argent, en réduisant
ABB France
Division Produits Basse Tension
les pertes directement au sein des tableaux. C'est dans cette
Activité Basse Tension
optique qu'a été développé le nouveau tableau MNS, équipé
Pour une alimentation sans interruption, prenez le contrôle.
du contacteur AF.
www.abb.fr
ABB France
Division Produits Basse Tension
Activité Basse Tension
1SFC101013L0301
Le client
Important producteur d'acier, SSAB est leader sur le marché
de niche de l'acier haute résistance. Avec des usines en Suède
et aux États-Unis, ainsi que des opérations de finition en
Chine, l'entreprise compte plus de 9 000 employés, répartis
dans 45 pays. Les hauts fourneaux et les fourneaux électriques
de SSAB consomment énormément d'électricité et imposent
des contraintes extrêmes sur la fourniture d'énergie en termes
de performance et de fiabilité. Pour garantir la continuité du
fonctionnement de ses générateurs, SSAB exige que ses
équipements de commande moteur soient certifiés SEMI-F47
(résistance aux coupures de tension). ABB est l'un des rares
fournisseurs capables de satisfaire les exigences strictes de
cette norme.
Le défi
La défaillance des contacteurs suite à des coupures de tension
(contacteur soudé en position fermée) engendrait des temps
d'arrêt non planifiés, des pertes de production et des coûts
importants liés à leur remplacement. Cela mettait en danger
la production ainsi que la sécurité des opérateurs. En effet,
la transformation du minerai en fusion à une température
d'environ 1 300 °C rend toute interruption potentiellement
dangereuse et un arrêt trop long risque de figer la matière à
l'intérieur des fours. SSAB devait trouver une solution offrant
des performances constantes et flexibles, y compris dans ces
conditions extrêmes.
Stay connected!
1SFC101011L0301
SSAB
Production d’acier
Quand la fiabilité devient la norme
1SFC101006L0301
ABB – Tableaux et Systèmes
Construction de tableaux
Fonctionnalité et durée de vie accrues
La solution d'ABB
Grâce à sa bobine électronique, le contacteur AF fonctionne
sur une plage de tension élargie, sur les réseaux 50 et 60 Hz,
en AC ou en DC. En outre, le limiteur de surtension est
intégré au contacteur. En combinant autant de fonctionnalités
dans un seul et même contacteur, la gamme AF offre non
seulement des performances techniques exceptionnelles,
mais permet également une réduction considérable, jusqu'à
90 %, du nombre de variantes nécessaires. L'offre est passée
Le client
de 45 références de bobines
pour couvrir toute la plage
les OEM du secteur CVC (chauffage,
de tension à seulement 4Bonne
avec lanouvelle
gammepour
de contacteurs
ventilation,
Russie, l'un de nos principaux
AF. Ces contacteurs permettent
uneclimatisation).
réduction desEnfrais
marchés,
la profite
croissance
rapide
d'administration et de logistique
qui
à la fois
auxdu secteur entraîne des
conséquences
difficiles à maîtriser
distributeurs et aux utilisateurs
finaux. L'extension
de la : explosion du niveau des
stocks et des
coûts administratifs.
C'est le problème auquel ont
clientèle n'est ainsi plus synonyme
d'augmentation
ingérable
été confrontés
et Freedes
Tech, deux fournisseurs moscovites
et coûteuse des stocks. Plus
besoin de ADL
proposer
CVC.
produits spécifiques pourdu
lessecteur
tensions
non standard : avec
seulement quatre bobines, la technologie AF gère toutes les
Le20
défi
tensions de commande de
à 500 V AC/DC.
fil de et
la leur
croissance
marché CVC russe, les entreprises
Avec leur technologie de Au
bobine
gammedu
complète
comme
et Free dans
Tech ont
d’accessoires, les contacteurs
AFADL
se situent
uneété contraintes de gonfler
considérablement
afin de pouvoir répondre à
catégorie à part, répondant
aux besoins deleurs
tousstocks
les clients.
la forte demande. L'accroissement et la diversification de la
ont par ailleurs
entraîné
la nécessité de proposer
Besoin de plus d'espaceclientèle
et de simplicité,
prenez
le contrôle.
toujours plus de produits. Il est donc devenu de plus en plus
difficile d'assurer les livraisons sous 48 heures. L'augmentation
ABB France
des stocks a, en outre, été accompagnée d'une augmentation
Division Produits Basse Tension
Activité Basse Tension des frais administratifs. Pour pouvoir continuer à servir
efficacement leur large clientèle, ADL et Free Tech ont ainsi
dû résoudre le problème posé par leurs stocks excessivement
www.abb.fr
volumineux. La solution d'ABB : le contacteur AF.
La solution d'ABB
Intégrant la toute dernière technologie de contrôle moteurs issue
de notre expérience de leader du secteur de l'énergie et de
l'automatisation, la nouvelle gamme de contacteurs AF redéfinit
la norme en termes de contrôle industriel. Compatible à la fois
avec les alimentations AC et DC, le contacteur AF fonctionne
sur une plage de tension de commande considérablement
plus large que les contacteurs classiques. Grâce à sa bobine
électronique (limiteur de surtension intégré), un seul contacteur
est capable de fonctionner sur une plage de 100-250 V. Il est
en outre compatible avec les réseaux 50 et 60 Hz. En 2011, en
adoptant les contacteurs AF d'ABB, ADL et Free Tech ont pu
réduire leurs stocks de contacteurs de plus de 60 % et les frais
de gestion associés de 40 %. Le respect de délais de livraison
n'est pour eux désormais plus un problème, ce qui a permis
à ces deux entreprises de rester en tête du marché en pleine
croissance. La gamme AF offre de nombreux avantages, des
années de recherche et de développement ont permis à ABB
de réduire le nombre de variantes de produits de 90 %, tout en
continuant à proposer un contacteur pour chaque application.
Grâce à cette technologie, les fluctuations de tension ou les
tensions de commande non standard ne sont plus un problème.
Tools
Vous avez besoin de plus de flexibilité, prenez le contrôle.
ABB France
Division Produits Basse Tension
Activité Basse Tension
www.abb.fr
www.abb.fr
Success stories
Short-form
control
tactors
tection and
Motor pro tor starters, con
Manual mo d relays
rloa
and ove
Main catalog
Main catalog
Motor protection and control
Manual motor starters, contactors
and overload relays
Cadenas portal: Download 2D or 3D files according to your needs (STEP, IGES...)
Main catalog : 1SBC100192C0201
Short form catalog : 1SBC100180C0201
Panorama : 1SBC100191L0201
SOC II: Select the Optimized Coordination tables
for your starter according to IEC or UL standard
ABB | 14/1
1SBC101912S0201
For direct product details information,
use product type or order code, ex:
- www.abb.com/productdetails/AF09-30-10-13 or
- www.abb.com/productdetails/1SBL137001R1310
14
ABB France
Low Voltage Products Division
3, rue Jean Perrin
F-69687 Chassieu cedex / France
ABB STOTZ-KONTAKT GmbH
Eppelheimer Straße 82
D-69123 Heidelberg / Germany
Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice.
ABB does not accept any responsibility whatsoever
for potential errors or possible lack of information in
this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents – in whole or in parts – is
forbidden without prior written consent of ABB.
Copyright© 2014 ABB - All rights reserved
ABB AB
Control Products
Low Voltage Products
SE-721 61 Västerås / Sweden
You can find the address of your local sales organisation
on the ABB home page
www.abb.com/connecttocontrol
www.abb.com/lowvoltage
1SBC100192C0201 - Printed in France (07.2014 PDF)
Contact us
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Create Date : 2014:07:08 13:53:14+02:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2014:08:25 16:22:07+02:00 Subject : Title : Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Instance ID : uuid:e8f94876-e907-489f-bf5e-62b9b800be5d Original Document ID : adobe:docid:indd:82079db4-7336-11e0-9087-f8d7817714c2 Document ID : xmp.id:DD7DFE549606E411AEE4AA8530B18048 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:14FB8014D305E411B763E087A8D6481F Derived From Document ID : xmp.did:3729744E9219E111A18EA175AA3450C6 Derived From Original Document ID: adobe:docid:indd:82079db4-7336-11e0-9087-f8d7817714c2 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:07:08 13:53:14+02:00 Metadata Date : 2014:08:25 16:22:07+02:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Layout : TwoColumnRight Page Mode : UseOutlines Page Count : 792EXIF Metadata provided by EXIF.tools