Zelio Logic Relays SR1 Brochure

119711-Attachment 119711-Attachment 119711-Attachment 785901 Batch12 unilog cesco-content

2016-10-06

: Pdf 136553-Brochure 136553-Brochure B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 16

Zelio-Logic Relays
SR1
File 8501
CONTENTS
Description Page
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Overview of Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wiring Diagrams and Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Catalog
03
Zelio-Logic™ Relay
Overview
3
10/03 © 2001-2003 Schneider Electric All Rights Reserved
Overview
The Zelio-Logic relay is more than a typical relay. It will accept inputs, and has relay outputs like a programmable controller, but can not be connected to a network. Because
it has timers, counters and clocks that can be programmed, this product is ideal for applications where a typical relay, timer or time clock isn’t enough, but a PLC is not justified.
The Zelio-Logic relay is designed for use in small automated systems.
It can be used in industrial and commercial applications.
Its small size and ease of programming provides a competitive alternative to traditional relays, timers and counters.
• Zelio-Logic relays with four outputs will accept a 60 line program.
• Zelio-Logic relays with eight outputs will accept a 80 line program.
Programming in Zelio-Soft can be done in ladder logic, electrical symbols or Zelio symbols.
The ease of programming, ensured by the universality of the contact language, meets all automation requirements and also the needs of the electrician.
The versions without display or buttons provide not only a competitively priced solution, but also the confidentiality of the program (blind version).
Programming can be carried out:
- independently, using the buttons on some smart relays,
- on a PC, using “Zelio Soft” software,
- on a Pocket PC, using “Zelio Soft Pocket PC” software.
Description Main Zelio-Logic Screen
SR1A, SR1B
1. Retractable mounting feet
2. Power supply terminals
3. LCD display (4 lines, 12
characters)
4. Screw terminal input connection
5. Input terminals (0-10 V analog or
24 Vdc discrete)
6. Delete or Cancellation button
7. Insert a new line button
8. Navigational keys or Input keys in
RUN mode
9. Selection or validation button
10. Escape button
11. Slot for memory back-up EEPROM
cartridge or cable connection for
down loading or uploading of
programs.
12. Screw terminal relay output
connections
13. Marking area
1. Status of inputs
2. RUN or STOP mode indication
3. Indication of a parameter (day and
time is default for relays with a
clock)
4. Status of outputs
SR1D, SR1E
1. Retractable mounting feet
2. Power supply terminals
3. Screw terminal input connections
4. Input terminals (0-10 V analog or 0-
10 V discrete) only applicable to
SR1-E
5. U/RUN: operating LED
Steady : power on, Stop mode,
Flashing : Run mode
Fast flashing : relay fault
6. Slot for memory back-up EEPROM
cartridge or cable connection for
down loading or uploading of
programs
7. Screw terminal relay output
connections
8. Marking area
Back-up memory
Allows a program to be copied into another smart relay (examples: for building identical equipment, remote transmission of updates).
The memory also allows a back-up copy of the program to be saved prior to exchanging the product.
When used with a smart relay without display or buttons, the copy of the program contained in the cartridge is automatically transferred into the smart relay at
power-up.
The dc relays have a fast input function “FILT”. This function allows faster detection of changes in state of the inputs. This mode should only be used when necessary
as it makes the relay inputs more sensitive to interference and contact bounce. A “Fast” or “Slow” choice is available.
123 4 5
6
7
8
9
10
11
13 12 1
1
2
3
4
1 2 3 4 5 6
STOP
MO 0 8 : 2 9
1 2 3 4
I1 I2 I3 I4 I5 I6
U/Run
IB IC
12 3 4
5
6
7
81
Zelio-Logic™ Relay
Overview
© 2001-2003 Schneider Electric All Rights Reserved
410/03
ix will work the inverse of Ix.
Example:
Function Electrical Scheme Ladder Language Zelio Relay Symbol Notes
Contact
N.O.
SPSTNO Ix
I corresponds to the real image of
the contact connected to the input of
the module.
N.C.
SPSTNC ix
i corresponds to the reversed image
of the contact connected to the input
of the module.
Standard Coil Qx The coil is energized when the
contacts to which it is connected are
closed.
Latch Coil (Set) SQ
The coil is energized when the
contacts to which it is connected are
closed.
It remains energized when the
contacts re-open.
Unlatch Coil (Reset) RQ
The coil is de-energized when the
contacts to which it is connected are
closed. It remains inactive when the
contacts re-open.
1314
22 21
A1A2
A1A2
S
A1A2
R
M
STOP START
M1
L2
L1
L2
L1
I2 Q1
Q1
I1 I2 Q1
Q1
i1
OR
Zelio-Logic™ Relay
Overview of Functions
5
10/03 © 2001-2003 Schneider Electric All Rights Reserved
Overview of Functions
For more information on these timers and counters, refer to the User’s Manual #SR1MAN01EN.
Ten Timers (provided as standard in all relays)
Each timer function can be programmed to function in one of the following eight modes:
On-Delay
On-Delay (with momentary input)
Off-Delay
One Shot
One Shot (when input is removed)
Repeat Cycle (with maintained input)
Repeat Cycle (with momentary input)
Totalizing Timer with Reset
Each timer function has a preset time in one of four timing ranges:
00.00 s (1/100 of a second) Maximum of 99.99 seconds
000.0 s (1/10 of a second) Maximum of 999.9 seconds (16.665 minutes)
00:00 M:S (Minutes: Seconds) Maximum of 99:59
00:00 H:M (Hours: Minutes) Maximum of 99:59
The time setting on each timer can be locked. A password is required to unlock the timer.
Ten Counters (provided as standard in all relays)
Count up and/or count down.
Each counter function can have a preset value of 0000 to 9999.
The counter setting on each counter can be locked. A password is required to unlock the counter.
A
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
a
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
C
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
B
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
W
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
D
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
d
T T 1
R T .
T . t
t = 0 0 . 0 0 S
O
T
T T 1
R T .
T .
t = 0 0 . 0 0 S
O
12
Zelio-Logic™ Relay
Overview of Functions
© 2001-2003 Schneider Electric All Rights Reserved
610/03
Some Versions Come With Four 24 Hour - 7 Day Clocks:
On each clock you can set: Example:
Start Day (Sunday or Monday)
End Day (Friday or Saturday)
Start Time Each Day (08:30 or 9:15)
End Time Each Day (4:57 or 5:30)
The clock settings on each clock can be locked. A password is required to unlock the clock.
Fifteen Internal Relay Functions (provided as standard in all relays)
Each internal relay can have multiple contacts that can be used elsewhere in the program.
Each relay can be either a standard relay, a latching relay, or an unlatching relay.
The internal relays do not have connection points that could be used to control external loads.
These relays give much more freedom in programming.
Arrow Keys (4) on the Front of the Relay can be used as Inputs
They can be used as push buttons in the program.
Some of the 12 Vdc or 24 Vdc Versions have Analog Inputs
Analog inputs are only available on some 24 Vdc devices.
They can accept input values 0 through 10 V.
The following seven functions can be performed on the analog inputs:
Text messages can be entered using the Zelio-Soft software and then displayed on the relay.
Type of Function Description
Contact A1 is closed when the value of analog input IB does not exceed the reference voltage entered in the
reference field, 4.9 V in this example.
Contact A1 is closed when the value of analog input IB equals or exceeds the reference voltage entered in the
reference field, 4.9 V in this example.
Contact A1 is closed when the value of analog input IC does not exceed the reference voltage entered in the
reference field, 4.9 V in this example.
Contact A1 is closed when the value of analog input IC equals or exceeds the reference voltage entered in the
reference field, 4.9 V in this example.
Contact A1 is closed when the value of analog input IB does not exceed the value of
analog input IC.
Contact A1 is closed when the value of analog input IB equals or exceeds the value of
analog input IC.
Contact A1 is closed when the value of analog input IB is between IC-H and IC+H.
H (the hysteresis) is entered in the H field, 4.9 V in this example.
c
q
1 TU 2 2 4 9
A B C D M 0 S A
O N 0 9 : 0 0
O F F 1 3 : 0 0
Can be Used as Inputs
I B R e f
A 1 A n a l o g 1
R e f = 4 . 9 V
O
I B R e f
A 1 A n a l o g 2
R e f = 4 . 9 V
O
I C R e f
A 1 A n a l o g 3
R e f = 4 . 9 V
O
I C R e f
A 1 A n a l o g 4
R e f = 4 . 9 V
O
I B I C
A 1 A n a l o g 5
O
I B I C
A 1 A n a l o g 6
O
I C - H I B I C + H
A 1 A n a l o g 7
O
H = 4 . 9 V
Zelio-Logic™ Relay
Overview of Functions
7
10/03 © 2001-2003 Schneider Electric All Rights Reserved
“ZELIO-SOFT”: SOFTWARE
“Zelio-Soft” software enables:
the entering of control wiring diagrams
the monitoring of applications, using its test feature
the programming of messages for display on the “Zelio-Logic
simplification of setting-up
Input Modes for Control Wiring Diagrams
The “Zelio input” mode enables the user to program the Zelio Relay via software using the same key
strokes as used on the face of the Zelio Relay.
The “free input” mode, which is more intuitive, is very user friendly and incorporates several additional
features.
Using Zelio-Soft in “free mode” enables the user to select their preferred symbol language from the
following 3 alternatives:
Zelio symbols
Ladder symbols
Electrical symbols
The “free input” mode also enables the creation of notes associated to each line of the program.
Instant switching between one input mode and another is obtained by clicking the mouse.
Basic Programming Error Check and Applicable Language
The basic programming error check feature of Zelio-Soft monitors the applications and an input error
will turn the tool bar eye red. A mouse click on the eye will locate the problem.
At any time, Zelio-Soft can be switched between 6 applicable languages (English, French, German,
Italian, Portuguese and Spanish) including the editing of the application file. It also enables selection of
the representation mode (Zelio, Ladder or electrical) for editing the file.
Inputting Messages for Display on Zelio-Logic
Zelio-Soft allows 4 Text function blocks to be configured, corresponding to 4 screens of 4 lines x 12
characters, which can be displayed on all the relays. These screens are activated in the same manner
as a coil in the control scheme. It is then possible to display messages as text only or to associate them
with 1 or 2 variables, the latter being current values, and/or setting of function blocks used in the
program.
Set-Up Simulation
The Zelio-Soft simulator enables testing of all the programs, i.e.:
activating the discrete inputs and their N.O. or N.C. contact modes (momentary or maintained)
indicating the output states
varying the voltage of the analog inputs IB and IC
activating the pushbuttons
simulating the application program in real time and accelerated time
dynamically indicating in red the various active elements of the program
Zelio-Logic™ Relay
Overview of Functions
© 2001-2003 Schneider Electric All Rights Reserved
810/03
Zelio Soft Software for Pocket PC
The Pocket PC allows:
- full entry of control schemes, including the messages to be displayed on the smart relay screen (text blocks)
- transfer of programs created with Zelio Soft on a PC to the Pocket PC and vice versa
- transfer of programs created on a PC or on a Pocket PC to any smart module in the range and vice versa, as well as debugging
of programs while connected or not connected to the smart relay
The Pocket PC therefore avoids having to move the PC or smart relays for transfer and debugging of applications.
It is particularly useful for setting up smart relays which do not have a display or buttons.
Recommenced Pocket PCs (1):
- Hewlett Packard “Jornada 525 or 545”, available under Telemecanique reference VW3-A8103pp
- Hewlett Packard “Jornada 545 and 548”, to be ordered directly from an HP dealer
- Compaq “Ipaq” 3630, to be ordered directly from a Compaq dealer
- Casio Casiopeia EM 505, to be ordered directly from a Casio dealer
Zelio Soft for Pocket PC
Includes virtually all the functions of Zelio Soft software for PC:
- inputting of control schemes in free input mode in a choice of 3 languages
- Zelio, Ladder or electrical symbols - with associated comments
- program coherence test
- inputting of text function blocks (text only or text + variables)
- supervision of programs (2) with:
- “on line” display of the program and current values of function blocks
- forcing of inputs, outputs, control relays and function block values
- adjustment of parameters, date and time
- switching from Stop to Run mode
The software can be quickly installed in the Pocket PC, via a PC, using a special installation CD (ref: SR1-SFT02).
Exchange of files between the Pocket PC and PC is achieved by means of the Active Sync software (version V3.1 or greater)
supplied with the Pocket PC.
After the software has been installed, the Pocket PC can be used independently, as the only programming and adjustment tool for
Zelio Logic smart.
(1) Likely to change as Pocket PC manufacturers develop their ranges. Please consult your usual supplier.
(2) Only with module versions greater than or equal to V1.7.
I1 I2L N I3 I4 I5 I6
Del.
z1
z3
z4z2
Ins.line
Sel./OKEsc.
I1 I2+– I3 I4 I5 I6 IB IC
O1 O2 O3 O4
O1 O2 O3 O4
I3 I4I1 I2L N I5 I6 I7 I9I8 IA IB IC
Del.
z1
z3
z4z2
Ins.line
Sel./OKEsc.
O1 O2 O3 O4 O5 O6 O7 O8
Input of a Control Screen
Program Test with Smart
Relay Connected
Supervision Mode
Configuration of a Time
Delay Function Block
Zelio-Logic™ Relay
Application Data
9
10/03 © 2001-2003 Schneider Electric All Rights Reserved
Application Data
Minimum level under test conditions defined by the standards.
Environmental Characteristics
Product Certifications
File E164866 CCN NRAQ
File E164866 CNN NRAQ7
CSA File LR203359 Guide 2252 01
CE C-Tick, GL
Degree of Protection IP 20
Temperature Operation 32 °F to 131°F (0 °C to 55 °C) conforming to IEC 60068-2-1
and 60068-2-2
Storage -13 °F to 158 °F (-25 °C to 70 °C) conforming to IEC 61131-2
Maximum Relative Humidity 95% without condensation or dripping water
Altitude 0 to 6500 ft (0 to 2000 m)
Mechanical Resistance Immunity to vibration Conforming to standard IEC 60068-2-6, test Fc
Immunity to mechanical shock Conforming to standard IEC 60068-2-27, test Ea
Resistance to Electrostatic Discharges Immunity to electrostatic discharges Conforming to standard IEC 61000-4-2, level 3
Resistance to HF Interference
Immunity to electromagnetic radiated fields Conforming to standard IEC 61000-4-3, level 3
Immunity to rapid, pulsed, transients Conforming to standard IEC 61000-4-4, level 3
Immunity to surges Conforming to standard IEC 61000-4-5
Immunity to damped oscillatory waves Conforming to standard IEC 61000-4-12
Supply Characteristics Vdc
Smart Relay Type SR1- B121JD A101BD
B121BD
A201BD
B201BD B122BD
Primary Nominal voltage V 12 24
Voltage limits Including ripple V 10.4...14.4 19.2…30
Nominal input current mA 105 83 130 45
Heat dissipation W 1.3 1.6 2.9 1.1
Hold up time (loss of power) Acceptable duration 1 ms, repeated 20 times
Protection Against polarity inversion
Supply Characteristics Vac
Smart Relay Type SR1- B101B B201B A101FU
B101FU
A201FU
B201FU
Primary Nominal voltage V 24 100...240
Voltage limits Including ripple V 20.4…26.4 85...264
Nominal frequency Hz 50-60 (47…63)
Nominal input current mA 80 130 100 Vac 50
240 Vac 27 100 Vac 80
240 Vac 40
Heat dissipation W3535.3
Hold up time (loss of power) Acceptable duration 10 ms, repeated 20 times
Isolation Primary / ground V 2000 (50-60 Hz)
Discrete 24 Vdc Input Characteristics
Smart Relay Type SR1-ppppBD SR1-ppppJD SR1-pppBD SR1-pppJD
Input I1 to IA IB and IC
Connection Screw terminals Screw terminals
Nominal value of inputs Voltage V 24 12 24 12
Current mA330.620.21
Input switching
limit values
State 1 Voltage V 15 6.5 9.9 9.9
Current mA > 1.8 > 1.6 0.16 0.16
State 0 Voltage V < 5 < 6.2 < 5 < 5
Current mA < 0.5 < 1.5 0.08 0.08
Input impedance at state 1 k 8438 57
Configurable response time State 0 to 1 ms 0.3 (fast)…3 (slow) 3 (not configurable)
State 1 to 0 ms 0.5 (fast)…5 (slow) 5 (not configurable)
Conformity to IEC 1131-2 Yes, Type 1 No
Sensor compatibility 3-wire Yes PNP (only) Yes
2-wire No No
Type of input Resistive
Isolation Between supply and inputs None
Between inputs None
Maximum counting frequency Hz 60
Zelio-Logic™ Relay
Application Data
© 2001-2003 Schneider Electric All Rights Reserved
10 10/03
AC Input Characteristics
Smart Relay Type SR1-pp01FU SR1-pp01B
Connection Screw terminals Screw terminals
Nominal value of inputs
Voltage V 100…240 24
Current mA 0.65 (U = 115 V)
1.3 (U = 240 V) 3 (U = 24 V)
Frequency Hz 47…63 47…63
Input switching limit values
At state 1 Voltage V 79 12
Current mA 0.4 (U = 240 V) 1.5
At state 0 Voltage V < 40 < 5
Current mA < 0.3 < 0.6
Response time
State 0 to 1 50/60 Hz ms 45…50 (U = 110 V),
85…90 (U = 240 V) 18…22
State 1 to 0 50/60 Hz ms 45…50 (U = 110 V),
18…22 (U = 240 V) 23…25
Isolation Between supply and inputs None None
Between inputs None None
Maximum counting frequency Hz 10 10
Integral Analog Input Characteristics
Smart Relay Type SR1-BpppBD SR1-B121JD
Analog inputs
Number of channels 2
Voltage range of input V 0-10
Input impedance k 62.5 at 10 V
Maximum non destructive voltage V ± 30 ± 15
Conversion
Resolution 8 bits
Conversion time Relay cycle time
Precision @ 25 °C ± 1.6% of the full range
@ 60 °C ± 2.9% of the full range
Repeat accuracy @ 55 °C < 0.1% of the full range
Isolation Between analog channel & supply V None
Wiring distance m 10 m maximum with shielded cable (sensor not isolated)
Relay Output Characteristics (Screw Terminal Connections) (1)
Smart Relay Type SR1-B121JD, SR1-p1p1BD,
SR1-p101FU, SR1-p101B SR1-p201BD, SR1-p201FU,
SR1-p201B
Number of Outputs Without common potential 4 8
Operating Limit Values 5-150 Vdc, 24-250 Vac
Contact Type N.O.
Thermal Current 8 A
Electrical Durability
for 500,000 Operating Cycles Utilization category
DC-12 24 Vdc
1.5 A
DC-13 24 Vdc L/R = 10 ms
0.6 A
AC-12 230 Vac
1.5 A
AC-15 230 Vac
0.9 A
Minimum Switching Capacity At 5 V minimum voltage 10 mA
Low Power Switching
Reliability of Contact 17 V - 5 mA
Failure rate for 100 million operating cycles: 1
Maximum Operating Rate No-load 10 Hz
At le 0.5 Hz
Mechanical Life In millions of operating cycles 10
Rated Impulse Withstand Voltage Conforming to IEC 60947-1 2.5 kV
Response Time Trip 10 ms
Reset 5 ms
Incorporated Protection Against short-circuit None
Against overvoltage and overload None
Connection to screw terminals
(Tightened using Ø 3.5
screwdriver)
Flex cable with cable end mm21 conductor: 0.14…1.5, cable: AWG26…AWG16
2 conductors: 0.14…0.75, cable: AWG26…AWG18
Semi-rigid cable mm21 conductor: 0.14…2.5, cable: AWG26…AWG14
Rigid cable mm21 conductor: 0.14…2.5, cable: AWG26…AWG14
2 conductors: 0.14…1.5, cable: AWG26…AWG16
Tightening torque Nm0.6
Zelio-Logic™ Relay
Application Data
11
10/03 © 2001-2003 Schneider Electric All Rights Reserved
(1) Characteristics at 55 °C for 60 % loading of inputs/outputs or at 45 °C for 100 % loading of inputs/outputs.
(2) If there is no volt-free contact between the relay output and the load.
(1) Minimum level under test conditions defined by the standards.
(2) Time between change of state of an input and change of state of an output directly linked by the program in the same cycle
(3) The values and states to be saved must be configured in the remanence menu (retains last known value of timers, counters,
latching relays, and internal logic relays).
(4) As from product version V1.7.
(3) Only for earlier version smart relays V1.1 and V1.2.
(5) Only for smart relay versions V1.1, V1.2, V1.5 and V1.6.
Transistor Output Characteristics (screw terminal connections)
Smart Relay Type SR1-B122BD
Number of outputs With positive polarity common potential 4 (PNP)
Operating limit values V 19.2…30
Loads
Nominal voltage V 24 Vdc
Nominal current A 0.5
Maximum current A 0.625 at 30 V
Drop out voltage At state 1 V 2 for I = 0.5 A
Response time Tr ip ms 1
Reset ms 1
Built-in protection Against overload and short-circuits
Against overvoltage (2)
Against inversions of power supply
Processing Characteristics
Smart Relay Type SR1 A1pppp, B1pppp A2pppp, B2pppp
Number of control scheme
lines 60 80
Maximum cycle time ms 6 8
Response time (2) ms
12 to 24
(SR1-B121JD and p1ppBD)
20 to 40
(SR1-p101FU and p101B)
14 to 26 (SR1-p201BD)
22 to 42
(SR1-p201FU and p201B)
Back-up time in case of
power failure
Day/time h 150 at 40 °C only applicable to SR1-B and SR1-E (4)
Program and adjustments For life, internal EEPROM
Current values and states (3) For life, internal EEPROM on smart relays SR1B/SR1E only (4)
Program memory checking At each power-up
Clock drift s y 6 per month
Time delay block accuracy ± 12 ms ± 0.5 % of the time displayed
Zelio Soft Software for the PC
Zelio Soft
SR1- Apppp Bp01B Bpp1BD Bp01FU B122BD B121JD Dpppp Epppp
Version 1.2 Yes No Yes (3) Yes (3) No No No No
Version 1.3 Yes No Yes (5) Yes (5) Yes (5) No No No
Version 1.4 Yes No Yes (5) Yes (5) Yes (5) No Yes Yes (5)
Version 1.5 Yes Yes Yes Yes Yes Yes Yes Yes
Zelio-Logic™ Relay
Application Data
© 2001-2003 Schneider Electric All Rights Reserved
12 10/03
OPERATING CURVES
Electrical Durability (in millions of operating cycles) (conforming to IEC 60947-5-1)
(1) DC-12: switching resistive loads and photo-coupler isolated solid state loads, L/R 1 ms.
(2) DC-13: switching electromagnets, L/R 2 x (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current
(with protection diode on load, use the DC-12 curves and apply a coefficient of 0.9 to the million of operating cycles value).
(3) AC-12: switching resistive loads and photo-coupler isolated solid state loads, cos 0.9.
(4) AC-14: switching electromagnetic loads whose power drawn with the electromagnet closed is 72 VA,
making: cos = 0.3, breaking: cos = 0.3.
(5) AC-15: switching electromagnetic loads whose power drawn with the electromagnet closed is > 72 VA,
making: cos = 0.7, breaking: cos = 0.4.
The product life expressed above is based on average usage and normal operating conditions. Actual operating life will vary with
conditions. The above statements are not intended to, nor shall they create any expressed or implied warranties as to product
operation or life. For information on the listed warranty offered on this product, refer to the Square D terms and conditions of sale
found in the Square D Digest.
DC Loads
DC-12 (1) DC-13 (2)
AC Loads
AC-13 (3) AC-14 (4)
AC-15 (5)
0 1.5120.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
24 V
48 V
Current (A)
Millions of Operating Cycles
0.1 0.3 0.5 0.7 0.9 10.2 0.4 0.6 0.8
0.0
1.4
1.2
1.0
0.8
0.6
0.4
0.2
L/R = 10 ms 24 V
L/R = 10 ms 48 V
L/R = 60 ms 48 V
L/R = 60 ms 24 V
Current (A)
Millions of Operating Cycles
0 0.5 1.5 2.5 3.5 4.51.0 2.0 3.0 4.0 5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
24 V
48 V
110 V
230 V
Current (A)
Millions of Operating Cycles
0 0.2 0.6 1.0 1.4 1.80.4 0.8 1.2 1.6 2
0.0
0.5
1.0
1.5
2.0
2.5
24 V
48 V
110 V
230 V
Current (A)
Millions of Operating Cycles
0.5 0.90.7 1.31.1 1.71.5 1.9
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
230 V 48 V
110 V
Current (A)
Millions of Operating Cycles
SR1101FU
Zelio-Logic™ Relay
Ordering Information
13
10/03 © 2001-2003 Schneider Electric All Rights Reserved
Ordering Information
2 configurable analog inputs.
Relays
Supply Voltage Inputs Outputs Blind Version With Clock Catalog Number Weight lb (kg)
12 Vdc 8 - 12 Vdc 4 Relay No Yes SRIB121JD 0.64 lb (0.290 kg)
24 Vdc
6 - 24 Vdc 4 Relay No No SR1A101BD 0.64 lb (0.290 kg)
6 - 24 Vdc 4 Relay Yes No SR1D101BD 0.64 lb (0.290 kg)
8 - 24 Vdc 4 Relay No Yes SR1B121BD 0.64 lb (0.290 kg)
8 - 24 Vdc 4 Relay Yes Yes SR1E121BD 0.64 lb (0.290 kg)
8 - 24 Vdc 4 Transistor No Yes SR1B122BD 0.64 lb (0.290 kg)
12 - 24 Vdc 8 Relay No No SR1A201BD 0.77 lb (0.350 kg)
12 - 24 Vdc 8 Relay No Yes SR1B201BD 0.77 lb (0.350 kg)
24 Vac 6 - 24 Vac 4 Relay No Yes SRIB101B 0.64 lb (0.290 kg)
12 - 24 Vac 8 Relay No Yes SRIB201B 0.64 lb (0.290 kg)
100 - 240 Vac
6 - 100/240 Vac 4 Relay No No SR1A101FU 0.64 lb (0.290 kg)
6 - 100/240 Vac 4 Relay No Yes SR1B101FU 0.64 lb (0.290 kg)
6 - 100/240 Vac 4 Relay Yes No SR1D101FU 0.64 lb (0.290 kg)
6 - 100/240 Vac 4 Relay Yes Yes SR1E101FU 0.64 lb (0.290 kg)
12 - 100/240 Vac 8 Relay No No SR1A201FU 0.77 lb (0.350 kg)
12 - 100/240 Vac 8 Relay No Yes SR1B201FU 0.77 lb (0.350 kg)
Separate Accessories
Description Catalog
Number
Weight
lb (kg)
Relay to PC interconnecting cable - 1.8 m length SR1CBL01 0.77 lb (0.350 kg)
EEPROM memory cartridge (1 k bytes) SR1MEM01 0.002 lb (0.001 kg)
Zelio-Soft Software SR1SFT01 0.33 lb (0.150 kg)
Zelio Soft Software for Pocket PC
Description Catalog
Number
Weight
lb (kg)
Connecting cable between Sub-D-9 connector on the Pocket PC and the smart relay SR1-CBL02 0.77 lb (0.350 kg)
Programming software for Pocket PC (also contains Zelio Soft multi-language software) SR1-SFT02 0.33 lb (0.150 kg)
Promotional Kits
Description Catalog
Number
Weight
lb (kg)
CD-ROM, and cable SR1KIT01 1.1 lb (0.500 kg)
SR1B121BD and SR1KIT01 SR1PACKBD 1.74 lb (0.790 kg)
SR1B101FU and SR1KIT01 SR1PACKFU 1.74 lb (0.790 kg)
Documentation
Description Language Catalog
Number
Weight
lb (kg)
Users guide
English SR1MAN01EN 0.0022 lb (0.001kg)
French SR1MAN01FR 0.0022 lb (0.001kg)
German SR1MAN01DE 0.0022 lb (0.001kg)
Italian SR1MAN01IT 0.0022 lb (0.001kg)
Spanish SR1MAN01ES 0.0022 lb (0.001kg)
Power Supply (1)
Input Voltage Nominal Output Voltage Nominal Output Current Catalog Number Weight lb (kg)
100…240 V
47…63 Hz
12 Vdc 1.9 A ABL-7RM1202 0.39 (0.180 kg)
24 Vdc 1.4 A ABL-7RM2401 0.40 (0.182 kg)
SR1121BD
SR1101FU
ABL-7RM2401
Zelio-Logic™ Relay
Wiring Diagrams and Dimensions
© 2001-2003 Schneider Electric All Rights Reserved
14 10/03
Wiring Diagrams and Dimensions
DIMENSIONS
WIRING DIAGRAMS
(1)1 A ultra fast fuse or supplementary protector
Catalog Number A
SR1A101BD
2.83 " (72 mm)
SR1B101B
SR1B121BD
SR1B121JD
SR1D101BD
SR1E121BD
SR1A101FU
SR1B101FU
SR1D101FU
SR1E101FU
SR1B122BD
SR1A201BD
4.96 " (126 mm)
SR1B201B
SR1B201BD
SR1A201FU
SR1B201FU
3-wire Sensor on: Analog Inputs on: Analog Inputs on:
SR1A101BD SR1B121BD SR1B201BD
SR1B121BD SR1E121BD
SR1B122BD SR1B122BD
SR1D101BD SR1B121JD
SR1E121BD
SR1A201BD
SR1B201BD
SR1B121JD
60
2.36
100
3.94
90
3.54
110
4.33
59.5
2.34
A
Dual Dimensions inches
mm
+
-
I1
1Q1 21Q2 21Q3 21Q4 2
I2 I3 I4 I5 I6 IB IC
24 Vdc
+
24 Vdc
BN
BK
BL
BN
BK
BL
(1)
+
24 Vdc
Ca / Ta
1Ca / Ta
2
+
-
I1
1Q1 21Q2 21Q3 21Q4 2
I2 I3 I4 I5 I6
IB IC
24 Vdc
(1)
0-10 Vdc Analog
+
-I1
1Q1 21Q2 21Q3 21Q4 21Q5 21Q6 21Q7 21Q8 2
I2 I3 I4 I5 I6
I7 I8 I9 IA IB IC
24 Vdc
--
+
24 Vdc
Ca / Ta
1Ca / Ta
2
0-10 Vdc Analog
(1)
Zelio-Logic™ Relay
Wiring Diagrams and Dimensions
15
10/03 © 2001-2003 Schneider Electric All Rights Reserved
WIRING DIAGRAMS, CONTINUED
(1) 1 A ultra fast fuse or circuit protector.
(2) 16 A maximum fuse or supplementary protector.
(3) Resistive load.
(4) Inductive load.
SR1A101BD or SR1D101BD SR1A201BD
SR1B121BD or SR1E121BD SR1B201BD
SR1B121JD
Terminals IB and IC are not available on this device.
SR1A101FU or SR1B101FU SR1A201FU or SR1B201FU
SR1B122BD SR1D101FU or SR1E101FU SR1A201B, SR1B201B
+
-
I1
1Q1 21Q2 21Q3 21Q4 2
I2 I3 I4 I5 I6 IBIC
24 Vdc
12-240 Vac
50 / 60 Hz
12-125 Vdc
L /
+
N /
-
U
12-240 Vac
24 Vdc
50 / 60 Hz
U
12-125 Vdc
L /
+
N /
-
(2)
(3)
(4)
(1)
or
+
-
I1
1Q1 21Q2 21Q3 21Q4 21Q5 21Q6 21Q7 21Q8 2
I2 I3 I4 I5 I6 I7 I8 I9 IA IB IC
24 Vdc
12-240 Vac
50 / 60 Hz
12-125 Vdc
L /
+
N /
-
U
12-240 Vac
24 Vdc
50 / 60 Hz
U
12-125
Vdc
L /
+
N /
-
(2)
(3)
(4)
(1)
--
or
24 V
24 V
+
I1
Q1 Q2 Q3
I2 I3 I4 I5 I6 IBIC
Q4
+
(1)
+
(2)
+
24 V
I1
1Q1 21Q2 21Q3 21Q4 2
I2 I3 I4 I5 I6
100-240 Vac
12-240 Vac
50 / 60 Hz
50 / 60 Hz
12-125 Vdc
L /
+
N /
-
U
12-240 Vac
100-240 Vac
50 / 60 Hz
U
12-125 Vdc
L
L N
N
(2)
(3)
(4)
(1)
or
1Q1 21Q2 21Q3 21Q4 21Q5 21Q6 21Q7 21Q8 2
12-240
Vac
50 / 60 Hz
12-125
Vdc
L /
+
N / -U
12-240 Vac
50 / 60 Hz
U
12-125
Vdc
(2)
(3)
(4)
(1)
100-240
Vac
100-240
Vac
50 / 60 Hz
L
N
L N
I1 I2 I3 I4 I5 I6 I7 I8 I9 IA IB IC
Catalog No. 8501CT0001R1/03 October 2003 © 2001–2003 Schneider Electric All Rights Reserved
Replaces 8501CT0001 dated February 20001.
Schneider Electric
8001 Highway 64 East
Knightdale, NC 27545
1-888-SquareD
(1-888-778-2733)
www.SquareD.com
Schneider Canada Inc.
19 Waterman Avenue,
M4B 1 Y2
Toronto, Ontario
1-800-565-6699
www.schneider-electric.ca

Navigation menu