GE Control Catalog Section 5
51356-Catalog 51356-Catalog 51356-Catalog 017018 Batch12 unilog cesco-content
357479-Attachment 357479-Attachment 357479-Attachment 425095 Batch12 unilog cesco-content
368823-Catalog 368823-Catalog 368823-Catalog 783166 Batch5 unilog cesco-content
108271-Catalog 108271-Catalog 108271-Catalog 017018 Batch7 unilog cesco-content
108271-Catalog 108271-Catalog 108271-Catalog 425095 Batch7 unilog cesco-content
2014-10-17
: Pdf 137490-Attachment 137490-Attachment 017018 Batch10 unilog
Open the PDF directly: View PDF .
Page Count: 110
Download | |
Open PDF In Browser | View PDF |
Section Updated 08 / 2013 IEC Power Devices Contactors Overview (C-2000) ...................................................5-3 Mini Contactors (C-2000) Overview.........................................................................................................5-4 Features and Benefits ..............................................................................5-5 Accessory Features ...................................................................................5-6 Product Offering..........................................................................................5-7 Product Number Selection Instructions...........................................5-7 Product Descriptions.................................................................................5-8 AC 3-Pole, Up to 600 VAC Coil, Nonreversing ...............................5-9 AC 3-Pole, Up to 250 VDC Coil, Nonreversing ............................5-10 AC 4-Pole, Up to 600 VAC Coil, Nonreversing.............................5-11 AC 4-Pole, Up to 250 VDC Coil, Nonreversing ............................5-12 AC 3-Pole, Up to 600 VAC Coil, Reversing ....................................5-13 AC 3-Pole, Up to 250 VDC Coil, Reversing....................................5-14 AC 3-Pole, Up to 24 VDC Coil, Nonreversing...............................5-15 Accessories.................................................................................................5-16 Overload Relays........................................................................................5-20 Overload Relays Accessories .............................................................5-20 Control Relays............................................................................................5-21 Control Relay Accessories ...................................................................5-23 Outlines and Dimensions .....................................................................5-24 Technical Information............................................................................5-31 Application Information .......................................................................5-34 Application Information Overload Relay Performance Curves..........................................5-35 Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Section 5 Contactors and Starters (C-2000) Introduction................................................................................................5-36 Product Number Selection Instructions........................................5-37 Contactors - Nonreversing and Reversing, AC Controlled, 3-Pole ..........................................................................5-38 Contactors - Nonreversing and Reversing, DC Controlled, 3-Pole..........................................................................5-39 Contactors - Nonreversing and Reversing, AC/DC Controlled, 3-Pole ..................................................................5-40 Contactors - Nonreversing, AC, DC, AC/DC Controlled, 4-Pole ..................................................................5-42 Contactors - Nonreversing, AC/DC Controlled, 4-Pole...........5-43 Contactors Accessories ........................................................................5-44 Contactor Coils..........................................................................................5-50 Contactor Enclosures.............................................................................5-51 Contactor Enclosure Accessories.....................................................5-52 Contactors Thermal Overload Relays ............................................5-53 Contactors Thermal Overload Relays Accessories..................5-57 Contactors Thermal Overload Relays Technical Characteristics..................................................................5-58 Control Relays Selection Guide .........................................................5-60 Control Relays Accessories .................................................................5-61 Specifications - Contactors, Starters, and Relays ....................5-64 Contactors Technical Data..................................................................5-65 Overload Relays Technical Data.......................................................5-68 Contactors Accessories Technical Data .......................................5-69 Contactors Lifetime Curves ................................................................5-70 Contactors Application Ratings-DC ................................................5-73 Contactors Application Ratings-AC.................................................5-74 Contactors Application Ratings-KVA ..............................................5-75 Contactors and Starters Type 2 Coordination...........................5-76 Contactors and Starters Wiring Diagrams..................................5-77 Contactors Dimensions ........................................................................5-79 Control Catalog 5-1 IEC Power Devices Section 5 Assembled Starters (C-2000) Selection Guide .........................................................................................5-95 Nonreversing, AC .....................................................................................5-97 Reversing, AC ..........................................................................................5-101 Wye-Delta, Open Transition, AC.....................................................5-105 Enclosures ................................................................................................5-109 5-2 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Contactor Overview C-2000 This Control Catalog section brings together products that conform to the International Electrical Commission (IEC) standards for worldwide markets. GE provides several complementary lines to meet the requirements of these standards: C-2000 Control Contactors and Starters GE’s C-2000 Control Contactors and Starters offer a wide array of contactors, relays, accessories, enclosures, and assembled starters to give you greater design versatility. C-2000 components are loaded with features that make them easier to install, allow more flexible configurations, lower inventory requirements, and make better use of panelboard space. These components conform to international standards (UL, cUL and IEC-947) and have dual (U.S./European) markings to ensure global acceptance. A single nomenclature system allows simple sourcing worldwide. AC coils (both 50 Hertz and 60 Hertz versions) and dc coils are available for a wide range of voltages for flexibility. Mini-Contactors C-2000 Mini-Contactors GE’s C-2000 Control Mini-Contactors are compact, convenient and compatible with most installation requirements. Various configurations can be created by combining the MCO contactors and MCR control relays with a wide selection of modular accessories. The high-performance Mini-Contactors are ideal for even highly demanding conditions. With a mechanical life rated at 10 million operations, and electrical life (AC-3) rated in excess of 1 million operations at rated current, they are ideal for many applications including pumps, fans, hoists, conveyors, and irrigation systems. Positive Guided Contacts All GE C-2000 contactors and relays offer positive guided contacts. This complies with the requirements of EH 60947-5-1. Except for auxiliary contacts BCL10G and BCLF01G, NO and NC auxiliary contacts and main contacts will not overlap. BCL10G and BCLF01G are intentionally designed to be overlapping. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-3 IEC Power Devices Section 5 Mini Contactors Overview C-2000 Application The MC family of mini-contactors and the MCR family of control relays offer the user and equipment designer a compact, reliable and versatile solution to today’s demanding requirement of high performance in a confined space. In such applications, PLC compatibility is playing an ever increased role. Contactors and control relays are available in either ac or dc controlled forms, and offer application flexibility through a wide variety of modular accessories. These devices are CE Marked and dual-rated for worldwide acceptance by complying to UL, cUL, and IEC 947 standards. Contactors and control relays may be conveniently mounted using a 35mm DIN rail or by affixing with screws to a base plate. Featuring a conveniently compact size, a mechanical life rated at 10 million operations, and an electrical life (AC-3) rated in excess of 1 million operations at rated current, the MC/MCR mini-contactor family is suitable for a wide variety of applications—including pumps, fans, door operators, hoists, conveyers, commercial laundry equipment, machine tools, food mixing equipment, irrigation systems, and other utilizations. Low coil power consumption greatly expands application flexibility. Standard ac coils require only 1.4 watts and standard dc coils require 3 watts; this translates into low control power supply requirements and low heat losses inside the enclosure. Two special 24 volt PLC interface coil versions are also available to allow coils to be directly operated by PLC outputs. The MC/MCR family of contactors and control relays offers compact size, performance and features typically found in larger contactors and relays. This combination expands application flexibility which is only limited by the imagination of the designer. Accessories A wide variety of accessories allows application flexibility to meet most installation requirements. Accessories include: —overload relays, —overload relay signal contact, —overload relay separate mounting base, —2-pole front auxiliary contacts, —4-pole front auxiliary contacts, —1-pole side auxiliary contacts, —surge suppressor, —mechanical interlock, —electronic timer Accessories are designed for quick and easy installation to either the front or side of the contactors or control relays. Product Number Selection Instructions: See page 5-7 5-4 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Features and Benefits C-2000 Easy Installation—Captive universal slot screws are standard on all contactors, relays, overloads, and accessories allowing installation with flat, star, and Phillips screwdrivers. All terminals are in the open position for production line and installation efficiency. Accessories are designed for fast installation on either contactors or relays. Safety Features—Finger and back-of-hand protection are provided. All screw and quick-connect type terminals are clearly marked with dual markings where applicable, for easy identification and wiring convenience. International Acceptance—Devices are listed and certified to international standards. Nameplate carries both IEC and North American standards. Modular Design—One of the most attractive features of this product family is its modularity. Various configurations can be created by combining the MC contactors and MCR control relays with the wide selection of available accessories. Compact Size—The contactor/relay mounting profile is approximately 1 3/4” x 1 7/8”. Long Life—The MC/MCR family of contactors and relays offers superior performance. Mechanical life is rated at 10,000,000 operations. Contactor motor ratings (AC-3) are in excess of 1,000,000 electrical operations. Reliable Operation—These products are manufactured with the latest advancements in materials technology and designed to ensure long, dependable operation. (Coils are designed for protection against burnout during demanding brownout conditions.) Flexible Mounting—Mounting is not restricted for contactor and relay applications; contactors may be horizontal-, tabletop-, or ceiling-mounted. Mounting flexibility is provided by a dual mounting system using either 35mm DIN rail or two #8 screws in opposite diagonal corners. The DIN rail release is located at the top, providing easy access when configured as a starter. Accessories are easily assembled to the MC/MCR contactors and relays, saving time while affording maximum versatility. High Short Circuit Current Ratings for UL508A – MC/MCR family of contactors UL rated to withstand 50,000 AIC fault when protected by Class H, L, J, CC or RK-5 fuses providing added performance to use within UL508A control panels. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Dual markings are provided. Special Orders—For OEMs and higher-volume applications, special terminal configurations are available, including quick-connect terminals (one 6.3mm Faston or two Faston 2.8mm) and pin terminals for printed circuit boards. Four-pole contactors with 4NO, 2NO/2NC or 4NC contacts can be ordered. Lower wattage 1.2w 24 Vdc and 2w 24 Vdc PLC contactor/relay versions also are available. (See Special PLC-Compatible Products, page 5-15.) Control Catalog 5-5 IEC Power Devices Section 5 Mini Contactors Accessory Features C-2000 Overload Relays—The Class 10 overload relay features include loss of phase sensitivity, ambient temperature compensation, choice of automatic or manual reset, trip indication (tripped “O”, operational “I”), trip test, separate stop (red), and reset (blue) buttons. Installation and wiring is simplified; the contactor coil connection A2 is fed directly into terminal 96 (NC contact) of the overload relay, making external coil/contact connecting wire unnecessary. The contactor holding interlock terminal (14) is fed through the overload relay for additional wiring convenience and simplification. Optional overload relay accessories include an addable snap-on NO signaling contact and a separate mount base/terminal assembly for applications where in-line installation is not convenient. The separate mounting base is suitable for either screw or DIN rail mounting. Auxiliary Contact Blocks—Front-mounted auxiliary blocks easily snap on the front of the MC/MCR contactors and relays. Frontmounted auxiliary contact blocks are available in either 3- or 4-pole versions. When mounting depth is critical, side auxiliary contact blocks may be easily assembled to each side of the contactor or control relay, using unique U-shaped keys. Up to two side auxiliary contact blocks may be added to each side of the contactor or relay. This unique family of front and side auxiliary contact blocks allows installation flexibility and also convenient mounting of additional accessories such as timers and surge suppressors. Control relays may be assembled with up to a maximum of ten contacts by using both front and side auxiliary contacts. Three-pole contactors may be assembled with up to seven auxiliary contacts, including the NO holding interlock. Surge Suppressor—Affords transient spike protection and assures proper control circuit operations through suppression of unwanted noise. Easily plugs into the contactor/relay front, making a wireless connection with the coil circuit. Quick, simple installation. Interlock feedthrough wire Coil connection Auto/manual reset button Setting dial Trip Indicator Trip Test Stop Button Mechanical Interlock—Designed for either ac or dc contactors. Allows field assembly of components into reversing contactors or starters. The mechanical interlock design is simple, easy to install, and allows a quick two-step conversion of components into reversing configurations. Electronic Timer—Adjustable from 0.5-60 seconds. The timer is available with wide ac/dc voltage (24-240 V) range, and is wired in series with the contactor or control relay coil. The electronic timer provides accurate, repeatable time delay upon energization. The timer block easily snaps onto the front of the contactor or relay, or may be fitted on the side, or may be panel/DIN rail mounted using the optional mounting base. Quick, efficient, simple and versatile. Coils—AC and DC coils may be changed to accommodate various voltages at distributor, OEM and user locations to allow inventory management and flexibility to serve a wide range of voltage/frequency requirements. Product Number Selection Instructions: See page 5-7 5-6 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Product Offering C-2000 Surge Suppressor MP0AAE Mechanical Interlock MMH0 Auxiliary Contact MATV10AT Overload Relay MT0 2-Pole, Front-Mounted Auxiliary Contact Block MARN2/MACN2 Contactor 5hp @ 460V MC1 Electronic Timer MREB Base For Separate Mount MVB0T Optional Timer Base MVB0R 1-Pole, Side-Mounted Auxiliary Contact Block MARL/MACL Input Terminals for Separate Mount MVE0T 4-Pole, Front-Mounted Auxiliary Contact Block MARN4/MACN4 Contactor 3hp @ 460V MC0 Control Relay MCR Mini-Contactors (up to 5 HP) Product Number Selection Instructions Pages 5-7 to 5-35 in this catalog include ordering and pricing information for the following product offerings, with G0-10A1 discount schedule: Contactors, AC- or DC-controlled, Overload relays, Reversing contactors, Control relays, Accessories, including: —Contactor auxiliary contact adder blocks, —Control relay auxiliary contact adder blocks, —Overload relay auxiliary contact adder blocks, —Mechanical interlock, —Reverser power wiring kit, —Electronic timing element, —Mounting adapter for electronic timing element, —Surge suppressors. Information includes product numbers, list prices, package quantities, and applicable rating data for proper selection. 1. Be sure to include coil suffix letter in product number where indicated for contactors, reversing contactors, and control relays. 2. For motor starter requirements, select the proper contactor and overload relay to meet your needs. 3. Order by complete product number. Example: For a 3.0 hp, 460 V, 3-phase, 60 Hertz motor with full-load amperes, AC-3 type duty current of 4.4 amperes and 120V control power... select open contactor with 120 V, 60 Hertz coil, MC0A310ATJ and overload relays MT03L. For an extra NO auxiliary contact on the overload, also order MATV10AT adder block. MC0A310ATJ1 MT03L MATV10AT $40.00 ea. GO-10A1 $40.00 ea. GO-10A1 $ 8.00 ea. GO-10A1 1J was added to the end of the product number to get a 120 V coil. 4. Contactors and accessories are packaged in multiple quantities for handling convenience. Order in quantities of 10 whenever possible. Additional Information Field-Installed Accessories Technical Information Dimensions and Weights Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com pages 5-16 pages 5-32 pages 5-24 Control Catalog 5-7 IEC Power Devices Section 5 Mini Contactors Product Descriptions C-2000 Full Voltage Mini Contactors - Nonreversing —Contactors are suitable for use on alternating current (ac) control circuits up to 600 volts and dc control circuits up to 240 volts. —All terminals are dual marked in accordance to EN50012, and U.S. marking standards. —Contactor may be mounted on 35mm DIN rail EN50022-35, or may be panel-mounted using two #8 screws in diagonal corners. —Screw and quick-connect terminals are protected against accidental contact in accordance with VDE0106T.100 and VBG4. —Low-coil wattage requirement makes contactors ideal for most applications. 24 Vdc PLC interface versions are available. (See Special PLC-Compatible Products, page 5-15.) —A wide range of accessories, including front-mounted auxiliary contact blocks, side-mounted auxiliary contact blocks, timer, and surge suppressors, are easily installed on contactors. Nonreversing Mini Contactor Full Voltage Mini Contactors - Reversing —Reversing contactor configuration includes two 3-pole contactors, mechanical interlock, power wiring, with a 1NO or 1NC auxiliary contact on each contactor. An optional auxiliary contact block for each contactor may be required for holding interlock or cross electrical interlock, depending upon the control circuit. Side auxiliary NO contacts may be easily added in the field. These must be added as a separate item, when required. —Reversing contactors are suitable for use on alternating current (ac) control circuits up to 600 volts, and dc control circuits up to 240 volts. —All terminals are dual marked in accordance to EN50012, and U.S. marking standards. —Reversing contactor may be mounted on 35mm DIN rail EN50022-35, or may be panel-mounted using two #8 screws in diagonal corners. —Optional quick-connect type or PC board terminal configurations are available. —Screw and quick-connect terminals are protected against accidental contact in accordance with VDE0106T.100 and VBG4. —A wide range of accessories are available. Reversing Mini Contactor Full Voltage Mini Contactors - PLC Compatible Reference Publications Three-Pole—Low Coil Wattage Contactors Instructions GEH-5475 MC Mini-Contactor/MT0 Thermal-Overload Relay. U.S. version. GEH-5931 MC Mini-Contactor Global Instructions GEH-5932 MT0 Thermal-Overload Relay Global Instructions While the standard line of MC0C dc operated contactors requires only 3 watts coil holding current, some PLC applications require lower wattage coils to efficiently interface with the PLC. Special contactors are available with 24 VDC coils, which only require 1.2 or 2 watts for pull in and holding. These contactors are available with screw terminal configuration. —All terminals are dual marked in accordance to EN50012, and U.S. marking standards. —Contactor may be mounted on 35mm DIN rail EN50022-35, or may be panel mounted using two #8 screws in diagonal corners. —Screw-type terminals are protected against accidental contact in accordance with VDE0106T.100 and VBG4. —Timer and surge suppressors are easily installed on contactors. A maximum of two auxiliary contacts are permissible on the 2 volt PLC version. Auxiliary contacts may not be utilized on the 1.2 watt version. Product Number Selection Instructions: See page 5-7 5-8 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors C-2000 AC 3-Pole, Up to 600 VAC Coil Nonreversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty Standard Screw-Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V 1 1 1.5 1.5 2.0 2.0 Auxiliary List Price Approx. Weight Contacts Product Number1 GO-10A1 Each 1NC 1NO 1NC 1NO 1NO 1NC MC0A301AT* MC0A310AT* MC1A301AT* MC1A310AT* MC2A310AT* MC2A301AT* $40.00 $40.00 $44.00 $44.00 $51.00 $51.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. Faston (2 x 2.8 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V 1 1 1.5 1.5 2.0 2.0 Auxiliary List Price Approx. Weight Contacts Product Number1 GO-10A1 Each 1NC 1NO 1NC 1NO 1NO 1NC MC0A301AF* MC0A310AF* MC1A301AF* MC1A310AF* MC2A310AF* MC2A301AF* $43.00 $43.00 $47.00 $47.00 $54.00 $54.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. Faston (1 x 6.3 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V 1 1 1.5 1.5 2.0 2.0 Auxiliary List Price Approx. Weight Contacts Product Number1 GO-10A1 Each 1NC 1NO 1NC 1NO 1NO 1NC MC0A301AH* MC0A310AH* MC1A301AH* MC1A310AH* MC2A310AH* MC2A301AH* $43.00 $43.00 $47.00 $47.00 $54.00 $54.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. Printed Circuit Board Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 1-Phase HP @60 Hz, 230V Auxiliary List Price Approx. Weight Contacts Product Number1 GO-10A1 Each 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NC MC0A301AI* 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NO MC0A310AI* 9.0A 3 3 5 5 4 1/2 1.5 1NC MC1A301AI* 9.0A 3 3 5 5 4 1/2 1.5 1NO MC1A310AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 1NO MC2A310AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 1NC MC2A301AI* 1Complete product number reference by replacing the “*” with the letter corresponding to the voltage and frequency of the control circuit. $43.00 $43.00 $47.00 $47.00 $54.00 $54.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. (Replace asterisk (*) in product number with coil product number suffix.) Coil Voltage Selection AC Coil Voltages Voltage 60 Hz 50 Hz Product Number Suffix Rev. 7/13 Prices and data subject to change without notice 24 C 24 D 120 110 J 208 M 240-277 220 N www.geindustrial.com 380 U 480 415 W 600 500 Y Control Catalog 5-9 IEC Power Devices Section 5 Mini Contactors C-2000 AC 3-Pole, Up to 250 VDC Coil Nonreversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty Standard Screw-Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 2.0 2.0 1NC 1NO 1NC 1NO 1NO 1NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 2.0 2.0 1NC 1NO 1NC 1NO 1NO 1NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 2.0 2.0 1NC 1NO 1NC 1NO 1NO 1NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts List Price Approx. Weight Product Number1 GO-10A1 Each MC0C301AT** MC0C310AT** MC1C301AT** MC1C310AT** MC2C310AT* MC2C301AT* $50.00 $50.00 $54.00 $54.00 $61.00 $61.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. Faston (2 x 2.8 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each MC0C301AF** MC0C310AF** MC1C301AF** MC1C310AF** MC2C310AF* MC2C301AF* $53.00 $53.00 $57.00 $57.00 $64.00 $64.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. Faston (1 x 6.3 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each MC0C301AH** MC0C310AH** MC1C301AH** MC1C310AH** MC2C310AH* MC2C301AH* $53.00 $53.00 $57.00 $57.00 $64.00 $64.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. Printed Circuit Board Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V List Price Approx. Weight Product Number1 GO-10A1 Each 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NC MC0C301AI** 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NO MC0C310AI** 9.0A 3 3 5 5 4 1/2 1.5 1NC MC1C301AI** 9.0A 3 3 5 5 4 1/2 1.5 1NO MC1C310AI** 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 1NO MC2C310AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 1NC MC2C301AI* 1Complete product number reference by replacing the “**” with the letter corresponding to the voltage and frequency of the control circuit. $53.00 $53.00 $57.00 $57.00 $64.00 $64.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. (Replace asterisks (**) in product number with coil product number suffix.) Coil Voltage Selection DC Coil Voltages Voltage DC Product Number Suffix 12 B 24 D 48 G 125 L 250 S Product Number Selection Instructions: See page 5-7 5-10 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors C-2000 AC 4-Pole, Up to 600 VAC Coil Nonreversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty Standard Screw-Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 6.0A 9.0A 9.0A 9.0A 12.0A 12.0A 12.0A 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3 5 5 5 7.5 7.5 7.5 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3 5 5 5 7.5 7.5 7.5 2.2 2.2 2.2 4 4 4 5.5 5.5 5.5 1/3 1/3 1/3 1/2 1/2 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1 1.5 1.5 1.5 2.0 2.0 2.0 4NO 4NC 2NO-2NC 4NO 4NC 2NO-2NC 4NO 2NO-2NC 4NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1 1.5 1.5 1.5 2.0 2.0 2.0 4NO 4NC 2NO-2NC 4NO 4NC 2NO-2NC 4NO 2NO-2NC 4NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1 1.5 1.5 1.5 2.0 2.0 2.0 4NO 4NC 2NO-2NC 4NO 4NC 2NO-2NC 4NO 2NO-2NC 4NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts List Price Approx. Weight Product Number1 GO-10A1 Each MC0A400AT* MC0AA00AT* MC0AB00AT* MC1A400AT* MC1AA00AT* MC1AB00AT* MC2A400AT* MC2AB00AT* MC2AA00AT* $40.00 $45.00 $44.00 $44.00 $49.00 $48.00 $56.00 $56.00 $56.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. Faston (2 x 2.8 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 6.0A 9.0A 9.0A 9.0A 12.0A 12.0A 12.0A 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3 5 5 5 7.5 7.5 7.5 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3 5 5 5 7.5 7.5 7.5 2.2 2.2 2.2 4 4 4 5.5 5.5 5.5 1/3 1/3 1/3 1/2 1/2 1/2 1/2 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each MC0A400AF* MC0AA00AF* MC0AB00AF* MC1A400AF* MC1AA00AF* MC1AB00AF* MC2A400AF* MC2AB00AF* MC2AA00AF* $43.00 $48.00 $47.00 $47.00 $52.00 $51.00 $59.00 $59.00 $59.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. Faston (1 x 6.3 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 6.0A 9.0A 9.0A 9.0A 12.0A 12.0A 12.0A 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3 5 5 5 7.5 7.5 7.5 1.5 1.5 1.5 3 3 3 3 3 3 3 3 3 5 5 5 7.5 7.5 7.5 2.2 2.2 2.2 4 4 4 5.5 5.5 5.5 1/3 1/3 1/3 1/2 1/2 1/2 1/2 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each MC0A400AH* MC0AA00AH* MC0AB00AH* MC1A400AH* MC1AA00AH* MC1AB00AH* MC2A400AH* MC2AB00AH* MC2AA00AH* $43.00 $48.00 $47.00 $47.00 $52.00 $51.00 $59.00 $59.00 $59.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. Printed Circuit Board Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V List Price Approx. Weight Product Number1 GO-10A1 Each 6.0A 1.5 1.5 3 3 2.2 1/3 1 4NO MC0A400AI* 6.0A 1.5 1.5 3 3 2.2 1/3 1 4NC MC0AA00AI* 6.0A 1.5 1.5 3 3 2.2 1/3 1 2NO-2NC MC0AB00AI* 9.0A 3 3 5 5 4 1/2 1.5 4NO MC1A400AI* 9.0A 3 3 5 5 4 1/2 1.5 4NC MC1AA00AI* 9.0A 3 3 5 5 4 1/2 1.5 2NO-2NC MC1AB00AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 4NO MC2A400AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 2NO-2NC MC2AB00AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 4NC MC2AA00AI* 1Complete product number reference by replacing the “*” with the letter corresponding to the voltage and frequency of the control circuit. $43.00 $48.00 $47.00 $47.00 $52.00 $51.00 $59.00 $59.00 $59.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. (Replace asterisk (*) in product number with coil product number suffix.) Coil Voltage Selection AC Coil Voltages Voltage 60 Hz 50 Hz Product Number Suffix Rev. 7/13 Prices and data subject to change without notice 24 C 24 D 120 110 J 208 M 240-277 220 N www.geindustrial.com 380 U 480 415 W 600 500 Y Control Catalog 5-11 IEC Power Devices Section 5 Mini Contactors C-2000 AC 4-Pole, Up to 250 VDC Coil Nonreversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty Standard Screw-Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 2.0 2.0 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 2.0 2.0 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 2.0 2.0 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts List Price Approx. Weight Product Number1 GO-10A1 Each MC0C400AT** MC0CB00AT** MC1C400AT** MC1CB00AT** MC2C400AT* MC2CB00AT* $50.00 $54.00 $54.00 $58.00 $65.00 $65.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. Faston (2 x 2.8 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each MC0C400AF** MC0CB00AF** MC1C400AF** MC1CB00AF** MC2C400AF* MC2CB00AF* $53.00 $57.00 $57.00 $61.00 $68.00 $68.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. Faston (1 x 6.3 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 12.0A 12.0A 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 1.5 1.5 3 3 3 3 3 3 5 5 7.5 7.5 2.2 2.2 4 4 5.5 5.5 1/3 1/3 1/2 1/2 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each MC0C400AH** MC0CB00AH** MC1C400AH** MC1CB00AH** MC2C400AH* MC2CB00AH* $53.00 $57.00 $57.00 $61.00 $68.00 $68.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. Printed Circuit Board Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V List Price Approx. Weight Product Number1 GO-10A1 Each 6.0A 1.5 1.5 3 3 2.2 1/3 1 4NO MC0C400AI** 6.0A 1.5 1.5 3 3 2.2 1/3 1 2NO-2NC MC0CB00AI** 9.0A 3 3 5 5 4 1/2 1.5 4NO MC1C400AI** 9.0A 3 3 5 5 4 1/2 1.5 2NO-2NC MC1CB00AI** 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 4NO MC2C400AI* 12.0A 3 3 7.5 7.5 5.5 1/2 2.0 2NO-2NC MC2CB00AI* 1Complete product number reference by replacing the “**” with the letter corresponding to the voltage and frequency of the control circuit. $53.00 $57.00 $57.00 $61.00 $68.00 $68.00 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. 8 oz. (Replace asterisks (**) in product number with coil product number suffix.) Coil Voltage Selection DC Coil Voltages Voltage DC Product Number Suffix 12 B 24 D 48 G 125 L 250 S Product Number Selection Instructions: See page 5-7 5-12 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors C-2000 AC 3-Pole, Up to 600 VAC Coil Reversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty Standard Screw-Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 1.5 1.5 3 3 3 3 5 5 1.5 1.5 3 3 3 3 5 5 2.2 2.2 4 4 1/3 1/3 1/2 1/2 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 1NO 1NC 1NO 1NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 1NC 1NO 1NC 1NO 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 1NC 1NO 1NC 1NO 1-Phase HP @60 Hz, 230V Auxiliary Contacts List Price Approx. Weight Product Number1 GO-10A1 Each TLIE1T* TLIE1U* TLIE2T* TLIE2U* $112.00 $112.00 $120.00 $120.00 13 oz. 13 oz. 13 oz. 13 oz. Faston (2 x 2.8 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 1.5 1.5 3 3 3 3 5 5 1.5 1.5 3 3 3 3 5 5 2.2 2.2 4 4 1/3 1/3 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each TLIE1E* TLIE1F* TLIE2E* TLIE2F* $118.00 $118.00 $126.00 $126.00 13 oz. 13 oz. 13 oz. 13 oz. Faston (1 x 6.3 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 1.5 1.5 3 3 3 3 5 5 1.5 1.5 3 3 3 3 5 5 2.2 2.2 4 4 1/3 1/3 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each TLIE1G* TLIE1H* TLIE2G* TLIE2H* $118.00 $118.00 $126.00 $126.00 13 oz. 13 oz. 13 oz. 13 oz. Printed Circuit Board Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V List Price Approx. Weight Product Number1 GO-10A1 Each 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NO TLIE1I* 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NC TLIE1J* 9.0A 3 3 5 5 4 1/2 1.5 1NO TLIE2I* 9.0A 3 3 5 5 4 1/2 1.5 1NC TLIE2J* 1Complete product number reference by replacing the “*” with the letter corresponding to the voltage and frequency of the control circuit. $118.00 $118.00 $126.00 $126.00 13 oz. 13 oz. 13 oz. 13 oz. (Replace asterisk (*) in product number with coil product number suffix.) Coil Voltage Selection AC Coil Voltages Voltage 60 Hz 50 Hz Product Number Suffix Rev. 7/13 Prices and data subject to change without notice 24 C 24 D 120 110 J 208 M 240-277 220 N www.geindustrial.com 380 U 480 415 W 600 500 Y Control Catalog 5-13 IEC Power Devices Section 5 Mini Contactors C-2000 AC 3-Pole, Up to 250 VDC Coil Reversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty Standard Screw-Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 1.5 1.5 3 3 3 3 5 5 1.5 1.5 3 3 3 3 5 5 2.2 2.2 4 4 1/3 1/3 1/2 1/2 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 1NO 1NC 1NO 1NC 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 1NC 1NO 1NC 1NO 1-Phase HP @60 Hz, 230V Auxiliary Contacts 1 1 1.5 1.5 1NC 1NO 1NC 1NO 1-Phase HP @60 Hz, 230V Auxiliary Contacts List Price Approx. Weight Product Number1 GO-10A1 Each TLICE1T** TLICE1U** TLICE2T** TLICE2U** $132.00 $132.00 $140.00 $140.00 16 oz. 16 oz. 16 oz. 16 oz. Faston (2 x 2.8 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 1.5 1.5 3 3 3 3 5 5 1.5 1.5 3 3 3 3 5 5 2.2 2.2 4 4 1/3 1/3 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each TLICE1E** TLICE1F** TLICE2E** TLICE2F** $138.00 $138.00 $146.00 $146.00 16 oz. 16 oz. 16 oz. 16 oz. Faston (1 x 6.3 mm) Quick Connection Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 9.0A 9.0A 1.5 1.5 3 3 3 3 5 5 1.5 1.5 3 3 3 3 5 5 2.2 2.2 4 4 1/3 1/3 1/2 1/2 List Price Approx. Weight Product Number1 GO-10A1 Each TLICE1G** TLICE1H** TLICE2G** TLICE2H** $138.00 $138.00 $146.00 $146.00 16 oz. 16 oz. 16 oz. 16 oz. Printed Circuit Board Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V List Price Approx. Weight Product Number1 GO-10A1 Each 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NO TLICE1I** 6.0A 1.5 1.5 3 3 2.2 1/3 1 1NC TLICE1J** 9.0A 3 3 5 5 4 1/2 1.5 1NO TLICE2I** 9.0A 3 3 5 5 4 1/2 1.5 1NC TLICE2J** 1Complete product number reference by replacing the “**” with the letter corresponding to the voltage and frequency of the control circuit. $138.00 $138.00 $146.00 $146.00 16 oz. 16 oz. 16 oz. 16 oz. (Replace asterisks (**) in product number with coil product number suffix.) Coil Voltage Selection DC Coil Voltages Voltage DC Product Number Suffix 12 B 24 D 48 G 125 L 250 S Product Number Selection Instructions: See page 5-7 5-14 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors C-2000 AC 3-Pole, Up to 24 VDC Coil Nonreversing Line Voltage - 600 VAC Maximum HP Ratings AC-3 Duty 24 VDC PLC Contactors Standard Screw Type Terminals Maximum Current 3-Phase HP 3-Phase HP, 3-Phase HP 3-Phase HP kW @ 50 Hz, 1-Phase HP @ 460 V (A) @60 Hz, 200-208V @60 Hz, 220-240V @60 Hz, 460-480V @60 Hz, 550-600V 380/415V @60 Hz, 115V 6.0A 6.0A 6.0A 6.0A 9.0A 9.0A 9.0A 9.0A 1.5 1.5 1.5 1.5 3 3 3 3 1.5 1.5 1.5 1.5 3 3 3 3 3 3 3 3 5 5 5 5 3 3 3 3 5 5 5 5 2.2 2.2 2.2 2.2 4 4 4 4 1/3 1/3 1/3 1/3 1/2 1/2 1/2 1/2 1-Phase HP @60 Hz, 230V 1 1 1 1 1.5 1.5 1.5 1.5 Contact Coil Configuration Wattage 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1.2w 1.2w 2w 2w 1.2w 1.2w 2w 2w Product Number List Price GO-10A1 MC0I310ATD MC0I301ATD MC0K310ATD MC0K301ATD MC1I310ATD MC1I301ATD MC1K310ATD MC1K301ATD $50.00 $50.00 $50.00 $50.00 $54.00 $54.00 $54.00 $54.00 Minimum order is 140 pieces. Packaged in multiples of 10 units. Each product number represents one unit. Select the Mini-Contactor product number that corresponds to the desired Contactor Rating. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-15 IEC Power Devices Section 5 Mini Contactors Accessories C-2000 Contact Rating A600, Q300 Contact Arrangement/ Terminal Numbers per EN 50005 MACN202AT 2-Pole Front-Mounted Auxiliary Contact Block MARN2/MACN2 4-Pole Front-Mounted Auxiliary Contact Block MARN4/MACN4 MACN211AT Front-Mounted Auxiliary Contact Blocks Contact Configuration 2NC 1NO-1NC 1NO-3NC 2NO-2NC 3NO-1NC For Use With Product Number List Price GO-10A1 Approx. Weight Each Contactors Contactors Contactors Contactors Contactors MACN202AT MACN211AT MACN413AT MACN422AT MACN431AT $12.00 $12.00 $22.00 $22.00 $22.00 1 oz. 1 oz. 2 oz. 2 oz. 2 oz. MACN413AT Packaged in multiples of 10 units. Each product number represents one unit. Front-mounted contacts may be combined with side auxiliary contacts for a total maximum number of six added auxiliary contacts. MACN422AT MACN431AT Product Number Selection Instructions: See page 5-7 5-16 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Accessories C-2000 Contact Rating A600, Q300 Contact Arrangement/ Terminal Numbers per EN 50005 MACL101AT Side-Mounted Auxiliary Contact Block MACL101ATS Side-Mounted Auxiliary Contact Blocks Contact Configuration 1NC 1NC 1NO 1NO 1NC 1NC 1NO 1NO For Use With Contactors Reversers Contactors Reversers Not Used in Combination w/ Top Auxiliary In Combination w/ Top Auxiliary Not Used in Combination with Top Auxiliary In Combination w/ Top Auxiliary Product Number MACL101AT MACL101ATS MACL110AT MACL110ATS MARL101AT MARL101ATS MARL110AT MARL110ATS List Price GO-10A1 Approx. Weight Each $8.00 $8.00 $8.00 $8.00 $8.00 $8.00 $8.00 $8.00 1 oz. 1 oz. 1 oz. 1 oz. 1 oz. 1 oz. 1 oz 1 oz. Packaged in multiples of 10 units. Each product number represents one unit. For quick-connect version 2 x 2.8 mm, replace the “T” with an “F” and add $2.00 (GO-10A1) to the list price. Up to four side auxiliary contacts may be installed on contactors or relays with standard coils with a maximum of two contacts per side. Optimum performance is obtained when the contact configuration is balanced. Side contacts may be combined with front-mount auxiliary contacts for a total maximum number of six added auxiliary contacts. MACL110AT MACL110ATS MARL101AT MARL101ATS MARL110AT MARL110ATS Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-17 IEC Power Devices Section 5 Mini Contactors Accessories C-2000 Mechanical Interlock Used for field assembly of reversing contactors and starters. Kit contains operating lever and 2 keys for joining either AC or DC contactors. Product Number MMH0 List Price GO-10A1 Approx. Weight Each Packing Quantity (No. Per Set) $8.00 0.1 oz. 10 Mechanical Interlock Electronic Timer Attaches either to the top or side of contactor or relay. Wired in series with the coil. May be used either with AC or DC coils. Timer operation range .5-60 seconds. Coil Voltage Product Number List Price GO-10A1 Approx. Weight Each Packing Quantity (No. Per Set) MREBC10AC2 $75.00 2 oz. 10 24-240V Electronic Timer Electronic Timer Base Allows timer to be either DIN rail- or panel-mounted. Product Number MVB0R List Price GO-10A1 Approx. Weight Each Packing Quantity (No. Per Set) $10.00 0.2 oz. 10 Electronic Timer Base Surge Suppressor Used to protect control circuits from voltage transients. Plugs into front of contactor, no external wiring required. RC type for AC and diode for DC. Coil Voltage Range 12-60V 50/60 Hz 72-240V 50/60 Hz 6-240 Vdc Product Number List Price GO-10A1 Approx. Weight Each MP0AAE1 MP0AAE2 MP0CAE3 $16.00 $16.00 $16.00 0.5 oz. 0.5 oz. 0.5 oz. Packing Quantity (No. Per Set) 10 10 10 Surge Suppressor Power Conductors for Reversing Contactor Used to parallel the input terminals and reverse output terminals of reversing contactors. Consists of six solid-formed wires. Product Number MVM01 List Price GO-10A1 Approx. Weight Each Packing Quantity (No. Per Set) $16.00 0.5 oz. 10 Power Conductors Product Number Selection Instructions: See page 5-7 5-18 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Accessories C-2000 AC Replacement Coils for Contactors and Control Relays Coil Voltage @ 60 Hz 6 12 24 — 32 48 60 110 120 — 208-220 240-277 — 380 440 480 600 12 24 42 110-115 120 220 230 240 440 Coil Voltage @ 50 Hz — — — 24 — 42 48 — 110 115-127 — 220-230 260 — 380-400 415-440 500 12 24 42 110-115 120 220 230 240 440 Product Number MBOAA MBOAB MBOAC MBOAD MBOAE MBOAF MBOAG MBOAH MBOAJ MBOAK MBOAM MBOAN MBOAS MBOAT MBOAU MBOAW MBOAY MBOA10 MBOA1 MBOA2 MBOA3 MBOA4 MBOA5 MBOA6 MBOA7 MBOA8 List Price GO-10A1 Approx. Weight Each Packing Quantity (minimum/multiples)1 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 $14.00 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. 10 10 1 10 10 10 10 10 1 10 1 1 10 10 1 1 1 10 10 10 10 10 10 10 10 10 List Price GO-10A1 Approx. Weight Each Packing Quantity (minimum/multiples)1 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 $18.00 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 3 oz. 10 1 1 10 10 10 1 10 10 10 10 1 10 10 1 10 10 10 DC Replacement Coils for Contactors and Control Relays Coil Voltage @ 60 Hz 6 12 24 32 36 42 48 60 72 110 120 125 220 240 250 15 24 24 Coil Voltage @ 50 Hz 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1.2 1.2 2 Product Number MBOCA MBOCB MBOCD MBOCC MBOCE MBOCF MBOCG MBOCH MBOCI MBOCJ MBOCK MBOCL MBOCN MBOCR MBOCS MBOI9 MBOID MBOKD 1Coils listed in package quantities of 10 are available in minimum quantities of 10 and in multiples of 10. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-19 IEC Power Devices Section 5 Mini Contactors Overload Relays C-2000 Overload Relays Fixed Heater C2000 overload relays provide motor overload protection through fixed bimetal heaters. These relays are ambient compensated and utilize a differential mechanism for singlephase sensitivity. The trip setting is adjustable for the range listed. Overload relays may be set for 2 different operational modes—manual reset only or automatic reset only. Stop is initiated by pushing the red stop button. —Class 10A trip —Ambient temperature compensation —Differential phase loss sensitivity —Trip indication —Manual trip test —Stop button (red) —Reset button (blue), two positions: manual (H) and automatic (A) —Pre-wired coil and NC contact connection —Auxiliary contact feed-through wire, to facilitate installation —Direct mounting or panel mount with base Mini Contactor Overload Relay Reference Publications Instructions GEH-5475 MC Mini-Contactor/MT03 Thermal-Overload Relay. U.S. version. GEH-5931 MC Mini-Contactor Global Instructions GEH-5932 MT03 Thermal-Overload Relay Global Instructions Overload Relays Current Range Amps (min-max) 0.11-0.17 0.17-0.26 0.26-0.43 0.43-0.65 0.65-1.0 0.85-1.3 1.1-1.6 1.35-2.0 1.7-2.4 2.2-3.2 3.0-4.7 4.0-6.3 5.5-8.0 7.5-10.5 10.0-14.0 Maximum Fuse Rating HRC11 Maximum Fuse Rating K5 Product Number List Price GO-10A1 Approx. Weight Each 1 1 3 3 6 6 6 10 15 20 30 40 50 MT03A MT03B MT03C MT03D MT03E MT03F MT03G MT03H MT03I MT03J MT03K MT03L MT03M MT03N MT03P $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 $40.00 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 4 oz. 2 4 6 6 10 10 16 16 16 20 25 35 50 Base Fixed Heater With Differential Protection for Direct Mounting to Contactor. Packaged in multiples of 10 units. Each product number represents one unit. Overload Relay Accessories Type Base for Separate Panel/Rail Mount of Overload Relay (Requires Power Input Terminals) Power Input Terminals Used in Conjunction with Base Instantaneous Auxiliary Contact Block for Relay, 1NO Contact Power Input Terminal List Price GO-10A1 Approx. Weight Each Packing Quantity1 MVB0T $3.00 1 oz. 5 MVE0T $9.00 2 oz. 5 MATV10AT2 $8.00 1 oz. 10 Product Number 1Pack quantity multiples. Each product number represents one unit. May be ordered in quantities less than 10. 2Adder block may be used with manual operation only. 5-20 Control Catalog Instantaneous Auxiliary Contact Block www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Control Relays Overview C-2000 Contact Rating A600, Q300 Control Relays —Relays are suitable for use on alternating current (ac) control circuits up to 600 volts, and dc control circuits up to 240 Volts. —All terminals are marked in accordance to EN50011. —Control relays may be mounted on 35mm DIN rail EN5002235, or may be panel-mounted using two or four #8 screws in diagonal corners. —Screw and quick-connect terminals are protected against accidental contact in accordance with VDE0106T.100 and VBG4. —Low-coil wattage requirement makes relay ideal for most applications. (24 Vdc PLC interface versions are available.) —A wide range of accessories, including front-mounted auxiliary contact blocks, side-mounted auxiliary contact blocks, a timer, and surge suppressors, are easily installed on relays. AC Operated Control Relay PLC Compatible Control Relays Low Coil Wattage Control Relays While the standard line of MCRC dc operated relays requires only 3 watts coil holding current, some PLC applications require lower wattage coils to efficiently interface with the PLC. Special relays are available with 24 Vdc coils which only require 1.2 or 2 watts for pull in and holding. These relays are available with screw terminal configuration. —All terminals are dual marked in accordance to EN50012, and U.S. marking standards. —Relay may be mounted on 35mm DIN rail EN50022-35, or may be panel-mounted using two #8 screws in diagonal corners. —Screw-type terminals are protected against accidental contact in accordance with VDE0106T.100 and VBG4. Reference Publications Instructions GEH-5475 MC Mini-Contactor/MT0 Thermal-Overload Relay. U.S. version. GEH-5931 MC Mini-Contactor Global Instructions GEH-5932 MT0 Thermal-Overload Relay Global Instructions Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-21 IEC Power Devices Section 5 Mini Control Relays Selection C-2000 Contact Rating A600, Q300 Contact Arrangement/ Terminal Numbers per EN 50011 AC Operated Control Relays Contact Configuration Mounting Type Product Number1,2 4NO 4NO 4NO 4NO 3NO-1NC 3NO-1NC 3NO-1NC 3NO-1NC 2NO-2NC 2NO-2NC 2NO-2NC 2NO-2NC 1NO-3NC 1NO-3NC 1NO-3NC 1NO-3NC 4NC 4NC 4NC 4NC Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board MCRA040AT* MCRA040AF* MCRA040AH* MCRA040AI* MCRA031AT* MCRA031AF* MCRA031AH* MCRA031AI* MCRA022AT* MCRA022AF* MCRA022AH* MCRA022AI* MCRA013AT* MCRA013AF* MCRA013AH* MCRA013AI* MCRA004AT* MCRA004AF* MCRA004AH* MCRA004AI* List Price GO-10A1 Approx. Weight Each $38.00 $41.00 $41.00 $41.00 $38.00 $41.00 $41.00 $41.00 $38.00 $41.00 $41.00 $41.00 $38.00 $41.00 $41.00 $41.00 $38.00 $41.00 $41.00 $41.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 13 23 33 43 A1 14 24 34 44 A2 4 NO 3 NO - 1 NC 1Complete product number reference by replacing the “*” with the letter corresponding to the voltage and frequency of the control circuit. 2 NO - 2 NC 2Packaged in multiples of 20 units. Each product number represents one unit. (Replace asterisk (*) in product number with coil product number suffix.) Coil Voltage Selection 13 21 31 41 A1 14 22 32 42 A2 AC Coil Voltages Voltage 60 Hz 50 Hz Product Number Suffix 24 120 110 J C 208 M 240-277 220 N 380 U 480 415 W 600 500 Y 1 NO - 3 NC DC Operated Control Relays Contact Configuration Mounting Type Product Number2,3 4NO 4NO 4NO 4NO 3NO-1NC 3NO-1NC 3NO-1NC 3NO-1NC 2NO-2NC 2NO-2NC 2NO-2NC 2NO-2NC Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board Standard Screw 2x2.8mm Faston 1x6.3mm Faston PC Board MCRC040AT** MCRC040AF** MCRC040AH** MCRC040AI** MCRC031AT** MCRC031AF** MCRC031AH** MCRC031AI** MCRC022AT** MCRC022AF** MCRC022AH** MCRC022AI** List Price GO-10A1 Approx. Weight Each $48.00 $51.00 $51.00 $51.00 $48.00 $51.00 $51.00 $51.00 $48.00 $51.00 $51.00 $51.00 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 6 oz. 4 NC 2Packaged in multiples of 20 units. Each product number represents one unit. 4 NO 3Complete product number reference by replacing the “**” with the letter corresponding to the voltage and frequency of the control circuit. (Replace asterisks (**) in product number with coil product number suffix.) Coil Voltage Selection DC Coil Voltages Voltage Product Number Suffix DC 12 B 24 D 48 G 125 L 250 S 13 21 33 43 A1 14 22 34 44 A2 3 NO - 1 NC PLC Control Relays—Standard Screw Type Terminals Contact Configuration 2NO-2NC 3NO-1NC 4 NO 2NO-2NC 3NO-1NC 4NO Coil Voltage Coil Wattage Product Number List Price GO-10A1 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 1.2w 1.2w 1.2w 2w 2w 2w MCRI022ATD MCRI031ATD MCRI040ATD MCRK022ATD MCRK031ATD MCRK040ATD $48.00 $48.00 $48.00 $48.00 $48.00 $48.00 2 NO - 2 NC Minimum order is 140 pieces. Packaged in multiples of 10 units. Each product number represents one unit. 5-22 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Control Relays Accessories C-2000 Contact Rating A600, Q300 Contact Arrangement/ Terminal Numbers per EN 50005 MARN220AT 2-Pole Front-Mounted Auxiliary Contact Block MARN2/MACN2 4-Pole Front-Mounted Auxiliary Contact Block MARN4/MACN4 MARN211AT Front-Mounted Auxiliary Contact Blocks Contact Configuration 2NO 1NO-1NC 2NC 4NO 3NO-1NC 2NO-2NC 1NO-3NC 4NC For Use With Product Number List Price GO-10A1 Approx. Weight Each Relays Relays Relays Relays Relays Relays Relays Relays MARN220AT MARN211AT MARN202AT MARN440AT MARN431AT MARN422AT MARN413AT MARN404AT $12.00 $12.00 $12.00 $22.00 $22.00 $22.00 $22.00 $22.00 1 oz. 1 oz. 1 oz. 2 oz. 2 oz. 2 oz. 2 oz. 2 oz. Packaged in multiples of 10 units. Each product number represents one unit. Front-mounted contacts may be combined with side auxiliary contacts for a total maximum number of six added auxiliary contacts. MARN202AT MARN440AT MARN431AT MARN422AT MARN413AT MARN404AT Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-23 IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Open-Type, AC-Controlled Contactors and Control Relays, STD and Quick-Connect Terminal Open-Type, AC-Controlled Starter, STD and Quick-Connect Terminal Product Number Selection Instructions: See page 5-7 5-24 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Open-Type, DC-Controlled Contactors and Control Relays, STD and Quick-Connect Terminal Open-Type, DC-Controlled Starter, STD and Quick-Connect Terminal Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-25 IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Open-Type, AC-Controlled Reversing Contactors, STD and Quick-Connect Terminal Open-Type, AC-Controlled Reversing Starter, STD and Quick-Connect Terminal Product Number Selection Instructions: See page 5-7 5-26 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Open-Type, DC-Controlled Reversing Contactors, STD and Quick-Connect Terminal Open-Type, DC-Controlled Reversing Starter, STD and Quick-Connect Terminal Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-27 IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Open-Type, AC-Controlled Contactors and Control Relays, PC Board Terminals Open-Type, DC-Controlled Contactors and Control Relays, PC Board Terminals Product Number Selection Instructions: See page 5-7 5-28 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Open-Type, AC-Controlled Reversing Contactors, PC Board Terminals Open-Type, DC-Controlled Reversing Contactors, PC Board Terminals Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-29 IEC Power Devices Section 5 Mini Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Panel-Mount O verload Relay Product Number Selection Instructions: See page 5-7 5-30 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Technical Information C-2000 Mini Contactors and Control Relays Standards and Listings International Certification Marks: In addition to stating the product number, the contactor nameplate also lists the international certification marks. All contactors, control relays, overload relays, and accessories are UL and cUL listed. Contactors and relays also conform to International Standards: —UL listed (Underwriters Laboratories, U.S. -UL 508, cUL); —CE Mark; —IEC 947-1,4 (International Electrotechnical Commission); —BS 5424 (British Standards, UK); —VDE 0660 (Verband Deutscher Elektotechniker, Federal Republic of Germany); —(S) (SEV, Switzerland-SEV 10254); —(D) (DEMCO, Denmark); —(N) (NEMCO, Norway); —(FI) (SETI, Finland); plus other specifications approvals... —CEI 17-3, 17-7 (Comitato Electrotechnico Italiano, Italy); —Bureau Veritas, France; —SEMKO, Sweden. Operating Characteristics/Technical Data: Contactors and Control Relays Ambient Conditions Operating Temperature Storage Temperature –20 to +55°C (–4 to +131°F) –30 to +80°C (–22 to +176°F) Altitude Derating Up to 10,000 ft. (3,000 m) Derating 10,000 to 13,200 ft. (3,000 to 4,000 m) Derating 13,200 to 16,000 ft. (4,000 to 5,000 m) Rated current .9 x’s rated current .8 x’s rated current Shock Resistance (All Axis) Closed 80% voltage - Admissible accel. Closed 80% voltage - Impulse duration Open no voltage - Admissible acceleration Open no voltage - Impulse duration 30g 11 ms 10g 11 ms Vibration Resistance Closed 80% voltage-Admissible accel. Closed 80% voltage - Sweep between Open No voltage-Admissible accel. Open No voltage - Impulse duration 10g 10-200 hz 5g 10-200 hz Terminal Capacity Screw Terminal Wire size Screw Terminal Wire temperature class Quick connect (Faston 2.8mm) Wire size Quick connect (Faston 2.8mm) Max. thermal current Printed circuit terminal - Hole size Tightening Torque (2) #14-18 AWG max. 60°C/75°C wire (2) 1mm2 8 amps 1.8mm 7 inch lbs. Operating Position Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-31 IEC Power Devices Section 5 Mini Contactors Technical Information C-2000 Main Contacts Data - Contactors Rated insulation voltage (IEC 947-1) Rated thermal current (UL 508) Frequency limits Impedance per pole Power dissipation AC-1 Power dissipation AC-3 Insulation resistance No overlap between NO and NC contacts - Space No overlap between NO and NC contacts - Time Overload Relay Auxiliary Contact Data Rated insulation voltage (IEC 947-1) Rated thermal current (UL 508) Contact Rating Frequency limits 660V 16 amps 25-400 Hz 1.76 m ohm 0.7 W .13W >10 m ohm 1mm >2ms Control Circuit Ratings 120 Vac, 125 Vdc Time A600 B600 Q600 R300 Main Contacts Data - Control Relays Rated insulation voltage (IEC 947-1) Rated thermal current (UL 508) Contact Rating Frequency limits Impedance per pole No overlap between NO and NC contacts - Space No overlap between NO and NC contacts - Time 660V 6 amps B600, R300 25-400 Hz 660V 10 amps A600, Q600 25-400 Hz 2.4 m ohm 1.1mm >2ms Carry Continuous Amperes 10 5 2.5 1.0 Rating AC AC DC DC Make Momentary Amperes 60 30 0.55 0.22 Break Amperes 6 3 0.55 0.22 For other voltages, reference NEMA ICS 3-125 or contact your nearest GE Energy Representative. Control Circuit Data: Pickup/Dropout % Coil Voltage Type Coil AC Controlled DC Controlled PLC interface (1.2w) PLC interface (2w) Instantaneous Auxiliary Contact Data Rated insulation voltage (IEC 947-1) Rated thermal current (UL 508) Contact Rating Frequency limits Impedance per pole Insulation resistance No overlap between NO and NC contacts - Space No overlap between NO and NC contacts - Time 660V 10 amps A600, Q600 25-400 Hz 2.4 m ohm >10 m ohm 1mm >2ms Pick-up 80%-110% 80%-110% 80%-125% 70%-125% Drop-out 35%-55% 20%-40% 20%-30% 20%-35% Opening/Closing Time Making (on Energization) (ms) Breaking (on De-energization) (ms) Type Coil Voltage NO Contact NC Contact NO Contact NC Contact AC Controlled (ms) +10-15% Nominal +10-15% Nominal +25-20% Nominal +25-30% Nominal 6-13 7-12 22-36 24-27 30-70 25-45 20-50 25-40 8-16 8-16 9-12 9-11 9-16 9-16 9-16 9-16 5-11 6-10 18-27 20-26 20-45 25-35 18-35 20-30 6-13 6-13 5-7 5-8 5-9 5-9 5-9 5-9 DC Controlled (ms) PLC Interface (1.2w) (ms) PLC Interface (2w) (ms) Maximum Operating Rate No load AC1 and AC3 at rated power AC4 at rated power 5-32 Coil Consumption Operations per Hour 9000 OPS/H 1200 OPS/H 300 OPS/H Control Catalog Type Coil AC Controlled DC Controlled PLC Interface (1.2w) PLC Interface (2w) Pick-up (Watts) 3 1.2 2 www.geindustrial.com Pick-up (VA) 26 Holding (Watts) Holding (VA) 4 Power Dissipation (Watts) 1.4 3 1.2 2 Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Technical Information C-2000 Operating Characteristics/Technical Data: Electronic Timer Performance Characteristics For use with all AC- and DC-controlled mini contactors and control relays. Contactor Electrical Life Utilization Categories Time Setting Reset Time Repeatability Voltage Range (AC/DC) Voltage Operating Limits Ambient Operating Temperature Ambient Storage Temperature Voltage Drop Load Current Load (maximum) @ 20º C Load (maximum) @ 40º C Load (maximum) @ 60º C Leakage Current Utilization categories are used to describe the type of motor load and duty cycle. Life/Load curves are then used to estimate electrical life of a specific controller. 0.5-60 seconds (adjustable) <100 milliseconds ± 1 percent 24-240V 80-110% -20°C to +55°C (-4°F to +131°F) -30°C to +80°C (-22°F to +176°F) 3 volts maximum 10 mA minimum .9 amps .72 amps .55 amps <5mA@240 volts The most common utilization categories are described below. (Each category has full-load current ratings defined to meet IEC standard requirements.) —AC-1-noninductive or slightly inductive loads, e.g., resistance furnaces. —AC-2-starting of slip ring motors without plugging. —AC-3-starting and stopping of squirrel-cage motors, i.e., this utilization category is typical of the standard type of motor duty encountered in most industrial applications. —AC-4-starting of squirrel-cage motors in inching, plugging, and reversing applications, i.e., this means continuous inching, plugging, and reversing. —AC-11-control circuit contact characteristics. Life/Load Curves Life/Load curves are used to estimate contact electrical life (millions of operations), based on rated operating current. First, determine the appropriate utilization category for which the contactor will be used. Select appropriate mini-contactor, based on motor horsepower, voltage, and full-load current to meet application needs. Estimated contact life (millions of operations) can then be determined by locating the point of intersection on the appropriate contactor curve of the rated operating current and contact life axes. (Curves are valid for up to 600 volt, 600 Hz operation.) Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-33 IEC Power Devices Section 5 Mini Contactors Application Information C-2000 5-34 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Mini Contactors Application Information C-2000 Overload Relay Performance Curves Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-35 IEC Power Devices Section 5 Contactors & Starters Introduction C-2000 Broad Line A wide array of contactors, relays, accessories, enclosures, and assembled starters give you greater design versatility. Broad Features C-2000 Control components are loaded with features that make them easier to install, allow more flexible configurations, lower inventory requirements, and make better use of panel space. And their performance is second to none. Broad Applications C-2000 components conform to international standards (UL, cUL, and IEC-947) and have dual (U.S./European) markings to ensure global acceptance. A single nomenclature system allows simple sourcing worldwide. AC coils (both 50 Hz and 60 Hz versions) and DC coils are available for a wide range of voltages for flexibility. For more information, refer to these other publications: DEA-016 DEP-070 DET-034 5-36 Promotional Brochure Selection Guide Technical Information Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 Contactors & Starters Selection Instructions C-2000 Your Choice: Components or Assembled Forms The C-2000 Starters & Contactors line offers ordering flexibility— individual components can be purchased, as well as assembled forms. Below are detailed instructions for ordering individual components—contactors, overloads, control relays, and accessories. For instructions on ordering assembled forms, please refer to pages 5-89 through 5-104. Accessories Select any required accessories from the Accessories section, pages 5-44 to 5-50. Contactors When the phase, horsepower, voltage, frequency, and full-load amps have been established (assuming AC-3 motor duty category 1), use the following steps as a guide to ordering: Step 1. Refer to contactor selection tables on pages 5-38 to 5-43. Select the correct table based upon number of poles (3 or 4), nonreversing or reversing, and coil operation (ac or dc). Step 2. Using the above motor characteristics, select the appropriate contactor product number. Step 3. Select correct coil suffix digit or letter from corresponding Coil Selection table. Step 4. To complete product number, replace asterisk (*) or crosshatch (#) with the selected coil suffix. Enclosures For field installation of an enclosed contactor or starter, select the proper enclosure from the Enclosures section (pages 5-51 to 5-52) based on the following criteria: —Type of enclosure: NEMA 1, NEMA 12/3R, or NEMA 4 —Contactor frame size 1If the motor duty is other than category AC-3, refer to the application life curves on pages 5-72 to 5-74 for selection of contactor. Overload Relays Step 1. Using the Overload Relay selection tables on pages 5-54 to 5-56, select the correct Overload Relay based on the following criteria: Manual/Automatic with/without Stop or Manual Only Class 10, 20, or Class 30 Contactor frame size Motor full-load amps (Select the overload in which the motor FLA falls within the overload current range.) Step 2. Select necessary accessories from the Accessories section, page 5-57. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Relays Step 1. Select control relay from selection table on page 5-63. Selection is based upon: —Contact arrangement (number of normally open and normally closed contacts) —AC or DC coil controlled Step 2. Select correct coil suffix symbol from corresponding Coil Selection table. Step 3. To complete product number, replace asterisk (*) with the selected coil suffix. Step 4. Select control relay accessories from Control Relay Accessories section on pages 5-64 to 5-66. Control Catalog 5-37 IEC Power Devices Section 5 IEC Contactors C-2000 Nonreversing and Reversing AC Controlled, 3-Pole HP Ratings AC-3 Duty 5-75 Hp (460V) Nonreversing Standard Terminals Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 10A 13.8A 17.5A 22A 32A 34A 48A 62A 68A 80A 96A 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts Product Number1 List Price GO-10C2 1.5 2 3 3 5 5 7.5 10 15 15 20 3 3 5 5 10 10 15 20 20 25 30 3 3 5 7.5 10 10 15 20 25 30 40 5 7.5 10 15 20 25 30 40 50 60 75 7.5 10 15 15 25 25 40 50 60 75 75 4 5.5 7.5 11 16 18.5 22 30 37 45 55 1NO 1NO 1NO 1NO 1NO 1NO 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC CL00A310T* CL01A310T* CL02A310T* CL25A310T*2 CL04A310M* CL45A310M*2 CL06A311M*3 CL07A311M*3 CL08A311M*3 CL09A311M*3 CL10A311M*3 $86.00 $109.00 $124.00 $138.00 $157.00 $173.00 $200.00 $240.00 $295.00 $333.00 $475.00 0.5 0.75 1 1.5 2 3 3 5 5 7.5 10 1To complete the contactor product number, replace * in the product number with the appropriate digit from the Coil Selection table. 2A 1NO front mounted auxiliary contact block is supplied (unassembled) with contactors that begin with CL25 and CL45. Add suffix “S” to product number for 1NO-1NC side auxiliary (assembled), add $11.00 GO-10C2 to list price (example: CL45A310MJS, list price $173.00 + $11.00 = $184.00 GO-10C2). 3A 1NO and 1NC front-mounted auxiliary contact block are supplied (unassembled) with contactors that begin with CL06, CL07, CL08, CL09, and CL10. Add suffix “S” to prod- uct number for 1NO-1NC side auxiliary (assembled), no addition in price adder. 5-10 Hp (460V) Nonreversing with Ring Terminal Capacity Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 10A 13.8A 17.5A 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts Product Number1 List Price GO-10C2 1.5 2 3 3 3 5 3 3 5 5 7.5 10 7.5 10 15 4 5.5 7.5 1NO 1NO 1NO CL00A310R* CL01A310R* CL02A310R* $94.00 $117.00 $132.00 Product Number1 List Price GO-10C2 0.5 0.75 1 1To complete the contactor product number, replace * in the product number with the appropriate digit from the Coil Selection table. 5-75 Hp (460V) Reversing Standard Terminals Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 10A 13.8A 17.5A 22A 32A 34A 48A 62A 68A 80A 96A 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts 1.5 2 3 3 5 5 7.5 10 15 15 20 3 3 5 5 10 10 15 20 20 25 30 3 3 5 7.5 10 10 15 20 25 30 40 5 7.5 10 15 20 25 30 40 50 60 75 7.5 10 15 15 25 25 40 50 60 75 75 4 5.5 7.5 11 16 18.5 22 30 37 45 55 1NO 1NO 1NO 1NO 1NO 1NO 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 0.5 0.75 1 1.5 2 3 3 5 5 7.5 10 LAR00A* LAR01A* LAR02A* LAR25A*4 LAR04A* LAR45A*4 LAR06A*5 LAR07A*5 LAR08A*5 LAR09A*5 LAR10A*5 $247.00 $293.00 $323.00 $351.00 $419.00 $451.00 $545.00 $625.00 $735.00 $861.00 $1145.00 1To complete the contactor product number, replace * in the product number with the appropriate digit from the Coil Selection table. 4Reversing contactors with prefixes LAR25 and LAR45 supplied with 1NO front-mounted holding interlock mounted on each contactor. Add suffix “S” to product number for 1NO-1NC side auxiliary (assembled), add $22.00 GO-10C2 to list price (example: LAR25AJS, list price $351.00 + $22.00 = $373.00 GO-10C2). 5Reversing contactors with prefixes LAR06, LAR07, LAR08, LAR09, and LAR10 supplied with 1NO and 1NC front-mounted auxiliary on each contactor. Add suffix “S” to prod- uct number for 1NO-1NC side auxiliary, no additional price adder. (Replace asterisk (*) in product number with appropriate digit from table below.) Coil Selection Table AC Voltage 60 Hz 24 48 120 208 277 240 480 — 600 50 Hz 24 42 110 — 220/230 — 380/400 415 500 *Coil Suffix 1 F J L N S U W Y Note: Additional coils available, see page 5-50 Product Number Selection Instructions: See page 5-37 5-38 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors C-2000 Nonreversing and Reversing DC Controlled, 3-Pole HP Ratings AC-3 Duty 5-25 Hp (460V) Nonreversing Standard Terminals Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 10A 13.8A 17.5A 22A 32A 34A 0.5 0.75 1 1.5 2 3 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts Product Number1 List Price GO-10C2 1.5 2 3 3 5 5 3 3 5 5 10 10 3 3 5 7.5 10 10 5 7.5 10 15 20 25 7.5 10 15 15 25 25 4 5.5 7.5 11 16 18.5 1NO 1NO 1NO 1NO 1NO 1NO CL00D310T# CL01D310T# CL02D310T# CL25D310T#2 CL04D310M# CL45D310M#2 $109.00 $133.00 $147.00 $166.00 $195.00 $252.00 1To complete the contactor product number, replace the # in the product number with the appropriate digit from the Coil Selection table. 2A 1NO front mounted auxiliary contact block is supplied (unassembled) with contactors that begin with CL25 and CL45. Add suffix “S” to product number for 1NO-1NC side auxiliary (assembled), add $11.00 GO-10C2 to list price (example: CL45D310MKS , list price $252.00 + $11.00 = $263.00 GO-10C2). 5-10 Hp (460V) Nonreversing with Ring Terminal Capacity Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 10A 13.8A 17.5A 0.5 0.75 1 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts Product Number1 List Price GO-10C2 1.5 2 3 3 3 5 3 3 5 5 7.5 10 7.5 10 15 4 5.5 7.5 1NO 1NO 1NO CL00D310R# CL01D310R# CL02D310R# $117.00 $141.00 $155.00 Product Number1 List Price GO-10C2 1To complete the contactor product number, replace the # in the product number with the appropriate digit from the Coil Selection table. 5-25 Hp (460V) Reversing3 Standard Terminals Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 10A 13.8A 17.5A 22A 32A 34A 0.5 0.75 1 1.5 2 3 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts 1.5 2 3 3 5 5 3 3 5 5 10 10 3 3 5 7.5 10 10 5 7.5 10 15 20 25 7.5 10 15 15 25 25 4 5.5 7.5 11 16 18.5 1NO 1NO 1NO 1NO 1NO 1NO LDR00A# LDR01A# LDR02A# LDR25A#4 LDR04A# LDR45A#4 $290.00 $337.00 $366.00 $399.00 $495.00 $609.00 1To complete the contactor product number, replace the # in the product number with the appropriate digit from the Coil Selection table. 3Reversing contactor consists of two (2) contactors, a mechanical interlock (BEL02) with built-in NC cross electrical contact, power wiring and cross electrical wiring and holding interlock. 4Reversing contactors with prefixes LDR25A and LDR45A supplied with 1NO front-mounted holding interlock mounted on each contactor. Add suffix “S” to product number for 1NO-1NC side auxiliary (assembled), add $22.00 GO-10C2 to list price (example: LDR25AKS, list price $399.00 + $22.00 = $421.00 GO-10C2). (Replace crosshatch (#) in product number with appropriate digit from table below.) Coil Selection Table (CL00, CL01, CL02, CL25, CL04, CL45) DC Voltage 12 24 48 125 250 #Coil Suffix B D G K T Note: Additional coils available, see page 5-50. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-39 IEC Power Devices Section 5 IEC Contactors C-2000 Nonreversing and Reversing AC/DC Controlled, 3-Pole HP Ratings AC-3 Duty 30-75 Hp (460V) Nonreversing Standard Terminals Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 48A 62A 68A 80A 96A 3 5 5 7.5 10 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts Product Number1 List Price GO-10C2 7.5 10 15 15 20 15 20 20 25 30 15 20 25 30 40 30 40 50 60 75 40 50 60 75 75 22 30 37 45 55 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC CL06E311M†2 CL07E311M†2 CL08E311M†2 CL09E311M†2 CL10E311M†2 $265.00 $279.00 $364.00 $404.00 $520.00 1To complete the contactor product number, replace the † in the product number with the appropriate digit from the Coil Selection table. 2Nonreversing: A 1NO and 1NC front-mounted auxiliary contact block are supplied (unassembled) with contactors that begin with CL06, CL07, CL08, CL09 and CL10. Add suffix “S” to product number for 1NO-1NC side auxiliary (assembled), no addition price adder. 30-75 Hp (460V) Reversing Standard Terminals Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 48A 62A 68A 80A 96A 3 5 5 7.5 10 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts 7.5 10 15 15 20 15 20 20 25 30 15 20 25 30 40 30 40 50 60 75 40 50 60 75 75 22 30 37 45 55 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC 1NO 1NC Product Number1 LER06A†3 LER07A†3 LER08A†3 LER09A†3 LER10A†3 List Price GO-10C2 $675.00 $703.00 $873.00 $1003.00 $1235.00 1To complete the contactor product number, replace the † in the product number with the appropriate digit from the Coil Selection table. 3Reversing: Reversing contactors with prefixes LER06, LER07, LER08, LER09, and LER10 supplied with 1NO and 1NC front-mounted auxiliary on each contactor. Add suffix “S” to product number for 1NO-1NC side auxiliary, no additional price adder. (Replace dagger (†) in product number with appropriate digit from table below.) Coil Selection Table (CL06, CL07, CL08, CL09, CL10) AC/DC Voltage 24-28 42-48 110-127 220-250 380-415 440-500 †Coil Suffix D F J N U Y Product Number Selection Instructions: See page 5-37 5-40 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors C-2000 Nonreversing and Reversing AC/DC Controlled, 3-Pole HP Ratings AC-3 Duty 100-500 Hp (460V) Nonreversing Bus Bar Terminals without Lugs Maximum Current @ 460 V (A) AC-3 140A 156A 192A 302A 398A 398A 480A 480A 602A 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts2 Product Number1 List Price GO-10C2 40 50 60 100 125 125 150 150 200 50 60 75 100 150 150 200 200 250 100 125 150 250 300 300 400 400 500 125 125 150 300 400 400 500 500 600 75 90 132 160 220 220 280 280 375 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC CK75CE311† CK08CE311† CK09BE311† CK95BE311† CK10CE311†3 CK10BE311† CK11CE311†3 CK11BE311† CK12BE311† $725.00 $945.00 $1325.00 $1800.00 $2700.00 $2970.00 $4200.00 $4620.00 $5700.00 1To complete the contactor product number, replace the † in the product number with the appropriate digit from the Coil Selection table. 2NO-1NC side auxiliary contact shipped unassembled (A600, Q600). 3CK10C and CK11C versions are for applications with maximum fuse 1000A, maximum breaker 600A. For higher ratings use CK10B and CK11B. Note that the CK10C and CK11C require less panel space. 100-500 Hp (460V) Reversing4 Bus Bar Terminals without Lugs Maximum Current @ 460 V (A) AC-3 140A 156A 192A 302A 398A 398A 480A 480A 602A 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V kW @ 50 Hz, 380/415V Auxiliary Contacts2 Product Number1 40 50 60 100 125 125 150 150 200 50 60 75 100 150 150 200 200 250 100 125 150 250 300 300 400 400 500 125 125 150 300 400 400 500 500 600 75 90 132 160 220 220 280 280 375 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC KAR75C† KAR08C† KAR09B† KAR95B† KAR10C† KAR10B† KAR11C† KAR11B† KAR12B† List Price GO-10C2 $2035.00 $2475.00 $3105.00 $4165.00 $6365.00 $6905.00 $9365.00 $10205.00 $12665.00 1To complete the contactor product number, replace the † in the product number with the appropriate digit from the Coil Selection table. 2NO-1NC side auxiliary contact shipped unassembled (A600, Q600). 4Reversing contactor consists of two (2) contactors, a mechanical interlock, baseplate, power bus bars, cross electrical wiring, and 1NO/1NC side-mounted auxiliary contact for cross electrical and holding interlock. Completely assembled. Note: KAR09 and KAR95 baseplate not suitable for starter assembly. Refer to page 5-88 for reversing starters. (Replace dagger (†) in product number with appropriate digit from table below.) Coil Selection Table AC 60/50 Hz 24-28 42-48 110-127 220-250 380-415 440-500 DC 24-28 42-28 110-127 220-250 380-415 440-500 †Coil Suffix D F J N U Y Coil suitable for either AC or DC power. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-41 IEC Power Devices Section 5 IEC Contactors C-2000 Nonreversing AC, DC, AC/DC Controlled, 4-Pole HP Ratings AC-3 Duty 7.5-60 Hp (460 V) Standard Terminals AC Controlled Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 13.8A 13.8A 17.5A 17.5A 25A 25A 32A 32A 42A 42A 62A 62A 68A 80A 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V Auxiliary Contacts Coil Type 2 2 3 3 3 3 5 5 7.5 7.5 10 10 10 15 3 3 5 5 7.5 7.5 10 10 10 10 20 20 20 25 3 3 5 5 7.5 7.5 10 10 15 15 20 20 25 30 7.5 7.5 10 10 15 15 20 20 30 30 40 40 50 60 10 10 15 15 20 20 25 25 30 30 50 50 60 75 None None None None None None None None None None None None None None AC AC AC AC AC AC AC AC AC AC AC AC AC AC 0.75 0.75 1 1 2 2 2 2 3 3 5 5 5 7.5 Contact Configuration Product Number1 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 2NO-2NC 4NO CL01A400T* CL01AB00T* CL02A400T* CL02AB00T* CL03A400M* CL03AB00M* CL04A400M* CL04AB00M* CL05A400M* CL05AB00M* CL07A400M* CL07AB00M* CL08AB00M* CL09A400M* List Price GO-10C2 $109.00 $109.00 $143.00 $143.00 $176.00 $176.00 $225.00 $225.00 $340.00 $340.00 $425.00 $425.00 $447.00 $475.00 (Replace asterisk (*) in product number with appropriate digit from table below.) Coil Selection Table AC Voltage 60 Hz 24 48 120 208 277 240 480 — 600 50 Hz 24 42 110 — 220/230 — 380/400 415 500 *Coil Suffix 1 F J L N S U W Y Additional Coils Available, see page 5-50. 7.5-20 Hp (460 V) Standard Terminals DC Controlled Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 13.8A 13.8A 17.5A 17.5A 25A 25A 32A 32A 0.75 0.75 1 1 2 2 2 2 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V Auxiliary Contacts Coil Type 2 2 3 3 3 3 5 5 3 3 5 5 7.5 7.5 10 10 3 3 5 5 7.5 7.5 10 10 7.5 7.5 10 10 15 15 20 20 10 10 15 15 20 20 25 25 None None None None None None None None DC DC DC DC DC DC DC DC Contact Configuration Product Number1 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC 4NO 2NO-2NC CL01D400T# CL01DB00T# CL02D400T# CL02DB00T# CL03D400M# CL03DB00M# CL04D400M# CL04DB00M# List Price GO-10C2 $132.00 $132.00 $166.00 $166.00 $232.00 $232.00 $263.00 $263.00 (Replace crosshatch (#) in product number with appropriate digit from table below.) Coil Selection Table DC Volts 24 48 120/125 250 #Coil Suffix D G K T 30-60 Hp (460 V) Standard Terminals AC/DC Controlled Maximum Current 1-Phase HP @ 460 V (A) AC-3 @60 Hz, 115V 48A 48A 62A 62A 68A 80A 3 3 5 5 5 7.5 1-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V Auxiliary Contacts Coil Type 7.5 7.5 10 10 10 15 10 10 20 20 20 25 15 15 20 20 25 30 30 30 40 40 50 60 30 30 50 50 60 75 None None None None None None AC/DC AC/DC AC/DC AC/DC AC/DC AC/DC Contact Configuration Product Number1 4NO 2NO-2NC 4NO 2NO-2NC 2NO-2NC 4NO CL05E400M† CL05EB00M† CL07E400M† CL07EB00M† CL08EB00M† CL09E400M† List Price GO-10C2 $405.00 $405.00 $484.00 $484.00 $516.00 $544.00 (Replace dagger (†) in product number with appropriate digit from table below.) Coil Selection Table DC/AC Volts †Coil Suffix 24-28 D 42-42 F 110-127 J 220-250 N 1To complete the contactor product number, replace the *, # or † in the product number with the appropriate digit from the Coil Selection table. Auxiliary contact shipped unassembled. Product Number Selection Instructions: See page 5-37 5-42 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors C-2000 Nonreversing AC/DC Controlled, 4-Pole HP Ratings AC-3 Duty 125-500 Hp (460V) Standard Terminals Maximum Current @ 460 V (A) AC-3 156A 192A 302A 398A 398A 480A 480A 602A 3-Phase HP @60 Hz, 200V 3-Phase HP @60 Hz, 230V 3-Phase HP @60 Hz, 460V 3-Phase HP @60 Hz, 575V Auxiliary Contacts2 Contact Configuration Product Number1 List Price GO-10C2 50 60 100 125 125 150 150 200 60 75 100 150 150 200 200 250 125 150 250 300 300 400 400 500 125 150 300 400 400 500 500 600 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 4NO 4NO 4NO 4NO 4NO 4NO 4NO 4NO CK08BE411† CK09BE411† CK95BE411† CK10CE411† CK10BE411† CK11CE411† CK11BE411† CK12BE411† $1375.00 $1750.00 $2250.00 $3520.00 $3872.00 $5250.00 $5775.00 $6900.00 1To complete the contactor product number, replace the †, in the product number with the appropriate digit from the Coil Selection table. 2Auxiliary contact shipped unassembled. (Replace dagger (†) in product number with appropriate digit from table below.) Coil Selection Table AC 60/50 Hz 24-28 42-48 110-127 220-250 380-415 440-500 Rev. 7/13 Prices and data subject to change without notice DC 24-28 42-48 110-127 220-250 380-415 440-500 †Coil Suffix D F J N U Y www.geindustrial.com Control Catalog 5-43 IEC Power Devices Section 5 IEC Contactors Accessories C-2000 Front-Mount Auxiliary Contact Blocks Front-mount auxiliary contact blocks clip onto front face of contactor. Contact Rating: A600, Q600. For Use With Terminal Type Contact Configuration Product Number List Price GO-10C2 CL Contactors CL Contactors CL Contactors CL Contactors CL Contactors CL Contactors Standard Standard Standard Standard Ring Ring 1NO 1NC 1NO 1NC 1NO 1NC BCLF10 BCLF01 BCLF10G1 BCLF01G1 BCRF10 BCRF01 $11.00 $11.00 $15.00 $15.00 $13.00 $13.00 Front-Mounted Block BCLF10/BCLF01/BCLF10G/BCLF01G 1Overlapping contacts. Side-Mount Auxiliary Contact Blocks Side-mount auxiliary contact blocks can be mounted on either left or right sides of contactor. Positive displacement contacts are designed to prevent simultaneous closing of NO and NC contacts to avoid overlapping between opposing functions. Contact Rating: A600, Q600. For Use With Terminal Type Type Contact Configuration Product Number List Price GO-10C2 Standard Standard Standard Standard Base Block Base Block Adder Block Adder Block 1NO-1NC 2NO 1NO-1NC 2NO BCLL11 BCLL20 BRLL11 BRLL20 $19.00 $19.00 $19.00 $19.00 CL/CK Contactors CL/CK Contactors CL/CK Contactors CL/CK Contactors BCRF10/BCRF01 Side-Mounted Block Mechanical Interlock Mechanical interlocks, used for horizontal interlocking of two contactors mounted sideby-side, prevent the closing of one contactor (as long as the other remains closed). BEL02 includes two built-in NC contacts. Contact Rating: A600, Q600. For Use With Product Number List Price GO-10C2 BELA02 BEKH $35.00 $65.00 5-75 Hp contactors (All CL Contactors) 100-500 Hp contactors (All CK Contactors) Pneumatic Timer BRLL11/BRLL20 Mechanical Interlock Pneumatic timers are adjustable time-delayed auxiliary contacts. They come equipped with two time-delayed contacts: 1NO and 1NC, electrically separated. Setting is scaled over a 350° rotation by means of a knurled knob with timing guide marks. To mount a pneumatic timer, simply clip it on front face of contactor. Contact Rating: A600, Q600. For Use With Terminal Type Type Time range Contact Configuration Product Number List Price GO-10C2 CL Contactors CL Contactors CL Contactors CL Contactors CL Contactors CL Contactors CL Contactors CL Contactors Standard Standard Standard Standard Ring Ring Ring Ring Time Delay On Time Delay On Time Delay Off Time Delay Off Time Delay On Time Delay On Time Delay Off Time Delay Off 1-30 sec 1-60 sec 1-30 sec 1-60 sec 1-30 sec 1-60 sec 1-30 sec 1-60 sec 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC BTLF30C BTLF60C BTLF30D BTLF60D BTRF30C BTRF60C BTRF30D BTRF60D $120.00 $120.00 $120.00 $120.00 $124.00 $124.00 $124.00 $124.00 Pneumatic Timer BTRF30C/BTRF60C/BTRF30D/BTRF60D Electronic Timers Time-on delay and time-off delay modules for sequencing control of contactors. They deliver high repeatability, ±3% in ambient temperatures from 32° to 104°F. A red LED provides indication during time-delay operation. For Use With CL00-CL10 with ac coils 24-250 V CL00-CL10 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL10 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL10 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL10 with dc coils 24-250 V Type Time-Delay Range Product Number List Price GO-10C2 On delay 0.1-2 s BETL02C $75.00 On delay 1.5-45 s BETL45C $75.00 Off delay 0.1-2 s BETL02D $85.00 Off delay 1.5-45 s BETL45D $85.00 BTLF30C/BTLF60C BTLF30D/BTLF60D Electronic Timer Product Number Selection Instructions: See page 5-37 5-44 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Accessories C-2000 Surge Suppressor For suppression of disturbances in circuit voltage occurring upon opening of the contactor. Mounts directly on the top of the coil. Note: Surge suppression is built into CK electronic coil module. For Use With Surge Suppressor Type Voltage Product Number List Price GO-10C2 RC RC RC RC RC RC Diode Varistor Varistor Varistor Varistor 24-48 VAC 50-127 VAC 130-240 VAC 24-48 VAC 50-127 VAC 130-240 VAC 12-600 VDC 24-48 VAC, DC 50-127 VAC, DC 130-250 VAC, DC 380-500 VAC, DC BSLR2G BSLR2K BSLR2R BSLR3G BSLR3K BSLR3R BSLDZ BSLV3G BSLV3K BSLV3R BSLV3U $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $32.00 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 All CL contactors All CL contactors All CL contactors All CL contactors All CL contactors Surge Suppressor BSLR _ _RC Amplifier A1 Provides for low level signals (24 VDC) to operate contactor while control coils operate at the line voltage. Two forms are available: a panel-mount form (for CK contactors) and a side-mount form (for CL contactors). For Use With Product Number GO Schedule List Price GO-10C2 CL Contactors CK Contactors CLXA01 CR305X112P GO-10C2 GO-10G $73.00 $54.00 + A2 BSLDZ Diode Mechanical Latch Block Mechanical latch block is used to convert a standard contactor into a latched contactor. Easy to mount, it clips onto front face of contactor. Contact Rating: A600, Q600. For Use With All CL Contactors All CL Contactors All CL Contactors All CL Contactors All CL Contactors All CL Contactors Voltage Application Release Voltage Range 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 24-32 42-48 110-125 208-277 380-480 500-600 Product Number RMLFD RMLFG RMLFJ RMLFN RMLFU RMLFY BLSV_ _Varistor List Price GO-10C2 $70.00 $70.00 $70.00 $70.00 $70.00 $70.00 Unlatching coil is rated for intermittent duty. The latch block features an integral coil contact to clear the circuit after unlatching. References Amplifier Instructions GEH-5517 Amplifier CLXA01 Mechanical Latch Block RMLF Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-45 IEC Power Devices Section 5 IEC Contactors Accessories C-2000 These modules add flexibility to C-2000 contactors and relays, providing time-delay functions, an interface for low voltage PLC applications or contactor-mounted manualauto functions. Easily installed, these modules plug right into the contactor coil terminals. All modules include a status indicating LED and accept plug-in voltage surge suppressors. Interface Modules Interface modules allow contactor operation from 24 Volt or 48 Volt sources (such as a PLC output). Current consumption is 15 mA @ 24 Vdc and 25 mA @ 48 Vdc. A red LED provides indication when voltage is applied to E1-E2. For Use With List Price Product Number GO-10C2 Input voltage Type 24 VDC Relay IMRD $50.00 48 VDC Relay IMRG $50.00 24 VDC Relay with manual override switch IMRFD $65.00 48 VDC Relay with manual override switch IMRFG $65.00 5-30 VDC Solid State (optical isolation) IMSSD $60.00 CL00-CL10 with ac coils 24-250 V CL00-CL45 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL45 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL45 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL45 with dc coils 24-250 V CL00-CL10 with ac coils 24-250 V CL00-CL10 with dc coils 24-250 V Interface Module Auto-Manual-Stop Modules Auto-Manual-Stop modules allow local and/or remote operation of the contactor coil. The Auto-Manual switch selects the input connected to the coil circuit—A1 for automatic or remote operation, B1 for local operation. In both connections, the manual On-Off switch is in series and controls power to the coil. Auto-Manual can be switched only when the On-Off switch is in the Off position. A red LED provides indication when the coil is energized. For Use With CL00-CL10 with ac coils 24-250 V CL00-CL45 with dc coils 24-250 V Product Number List Price GO-10C2 IMAMS $32.00 Auto-Manual-Stop Module Voltage Surge Suppressors Voltage surge suppressors plug into timer, interface, or auto-stop-manual modules. Contactor Size Coil Voltage Surge Suppressor Type Product Number List Price GO-10C2 CL00A-CL45A CL00A-CL45A CL00A-CL45A CL05A-CL10A CL05A-CL10A CL05A-CL10A CL00D-CL45D CL00-CL10 CL00-CL10 CL00-CL10 24-48 VAC 50-127 VAC 130-240 VAC 24-48 VAC 50-127 VAC 130-240 VAC 24-250 VAC 24-48 VAC or DC 50-127 VAC or DC 130-240 VAC or DC Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Diode Varistor Varistor Varistor IMRC2G IMRC2K IMRC2R IMRC3G IMRC3K IMRC3R IMD1Z IMV3G IMV3K IMV3R $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 Voltage Surge Suppressor Product Number Selection Instructions: See page 5-37 5-46 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Accessories C-2000 Starter Mounting Base For use with overload requiring jumpers. For Use With Overload Product Number List Price GO-10C2 CK08, CK09, CK95 contactors RT4, RT4L CKXB01 $40.00 Overload Jumpers Starter Mounting Base Overload jumpers allow an overload to be mounted to a contactor. Each product number represents a set of three overload jumpers. CKXJ02 consists of three insulated bus bar straps. Overloads and contactors are panel mounted. CKXJ10/CKXJ11 consist of three insulated bus bar straps, mounting brackets and mounting bracket hardware. For Use With CK09B, CK95B contactors CK10C, CK11C contactors CK10B, 11B, 12B contactors Overload Packing Quantity (No. Per Set) Product Number List Price GO-10C2 RT4 RT5 RT5 3 3 3 CKXJ021 CKXJ10 CKXJ11 $50.00 $60.00 $60.00 1CK95B uses 2 straps per terminal (2x CKXJ02) above 192 Amps. Overload Jumper Reversing Wiring Kits These kits provide interconnecting power wires for 3-phase squirrel-cage reversing contactors. For Use With CL00, CL01, CL02 contactors CL25 contactors CL04 contactors CL45 contactors CL06, CL07, CL08 contactors CL09, CL10 contactors Product Number List Price GO-10C2 CLXC01 CLXC11 CLXC21 CLXC31 CLXC41 CLXC51 $18.00 $20.00 $30.00 $32.00 $48.00 $60.00 Reversing Wiring Kit Reversing Bus Bar Kits Connection set for main power poles for assembly of reversing contactors. Note: The CKXC01, CKXC04, CKXC10, and CKCX11 are universal reversing contactor and starter bus bar kits consisting of three (3) line side and three (3) load side insulated bus bars plus six (6) power terminal extenders with bolts and hardware. When assembling reversing starters only three (3) power terminal extenders are required. Three (3) load side terminal extenders are replaced by overload connection straps purchased separately. For Use With CK75C, CK08C contactors CK09B, CK95B contactors CK10C, CK11C contactors CK12B contactors Rev. 7/13 Prices and data subject to change without notice Product Number List Price GO-10C2 CKXC04 CKXC01 CKXC10 CKXC11 $105.00 $125.00 $195.00 $205.00 www.geindustrial.com Reversing Bus Bar Kit Control Catalog 5-47 IEC Power Devices Section 5 IEC Contactors Accessories C-2000 Wye-Delta Wiring Kits Wiring kit consists of incoming terminal block and power wires. Motor Hp - 60 Hz, Three-Phase Delta Contactor M1 CL01, CL02 CL25 CL04 CL06 CL07 CL09, CL10 List Price Delta Contactor M2 Wye Contactor S1 Product Number 200-208 230 460 575 GO-10C2 CL01, CL02 CL25 CL04 CL06 CL07 CL09, CL10 CL00, CL01 CL01 CL04 CL04 CL06 CL07 CLXC02 CLXC12 CLXC22 CLXC42 CLXC43 CLXC52 – – 15 25 30 40, 60 – – 20 30 40 50, 60 15 25 40 60 75 100, 125 20 25 50 75 100 125 $58.00 $63.00 $63.00 $125.00 $125.00 $160.00 Wye-Delta Bus Bar Kits Connection set for main power poles for assembling wye-delta starters. Includes straps for connection to overload relay. For Use With Product Number List Price GO-10C2 CKXC05 CKXC03 CKXC13 CKXC12 $150.00 $180.00 $255.00 $295.00 CK75C, CK08C contactors, with RT3 overload CK09B, CK95B contactors, with RT4 overload CK10C, CK11C contactors, with RT5 overload CK10B, CK11B, CK12B contactors, with RT5 overload Wye-Delta Wiring Kit Electronic Timing Relay For use with wye-delta starters. Time range Product Number List Price GO-10RT 1-60 sec. with 100ms pause between wye contacts(17-18) opening and delta contact (17-28) closing METV $89.00 Input voltage 24 V (min.) to 240 V (max.) AC or DC Lugs Wye-Delta Bus Bar Kit Connector lugs with anti-turn feature. Suitable for copper wire only. Each lug kit contains three lugs. Wire Size Product Number List Price GO-10C2 6-250 kcmil CKX03 $52.00 6-350 kcmil CKX021 $60.00 6-500 kcmil 2/0-600 kcmil (2 wire lug) CKX01 $80.00 For Use With CK75C, CK08C contactors w/wo RT3 Overload CK09B, CK95B contactors w/wo RT4 Overload CK10, CK11, CK12 contactors w/wo RT5 Overload 1CK95: use 2 lugs per terminal above 218 Amps. Electronic Timing Relay Lugs Product Number Selection Instructions: See page 5-37 5-48 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Accessories C-2000 Contact Sets For Use With Packing Quantity (No. of Contact Sets) Contact Configuration Product Number 4 3 3 4 3 4 3 3 3 3 3 3 3 3 3 2NO-2NC NO NO 2NO-2NC NO 2NO-2NC NO NO NO NO NO NO NO NO NO VB1205B V31206B V31207B VB1207B V31208B VB1208B V31209B V31210B V31175CA V31108CA V31109BA V31195BA V31110CA V31111CA V31112BA CL05 contactors CL06 contactors CL07 contactors CL07 contactors CL08 contactors CL08 contactors CL09 contactors CL10 contactors CK75C contactors CK08C contactors CK09B, CK08B contactors CK95B contactors CK10C contactors CK11C contactors CK12B, CK10B, CK11B contactors List Price GO-10C2 $89.00 $67.00 $80.00 $106.00 $98.00 $130.00 $111.00 $160.00 $242.00 $380.00 $450.00 $620.00 $900.00 $1300.00 $1925.00 Contact Set Each set consists of 2 fixed contacts, 1 moving contact, and accessory parts. Miscellaneous Kits Type of Kit 35 mm DIN Rail (1 meter) Power Take-Off Terminals (wire size 12-18 AWG) Power Take-Off Terminals (wire size 12-18 AWG) Power Take-Off Terminals (wire size 12-18 AWG) Terminal Screw Kit Terminal Screw Kit For Use With Product Number List Price GO-10C2 CL00, CL01, CL02, CL25, CL04, CL45, CL06, CL07, CL08, CL09, CL10 contactors CK75C, CK08C contactors CLXR35 $8.00 CKXT03 $8.00 CK09B, CK95B, CK10C, CK11C contactors CKXT01 $10.00 CK12B contactors CKXT02 $12.00 CK75C, CK08C contactors CK09, CK95, CK10, CK11, CK12 contactors KVF75C KVF08C $5.00 $6.00 35mm DIN Rail Pole Terminal Protection For Use With Product Number List Price GO-10C2 CK75 - CK08 CK75 - CK95 CK10 - CK12 PTPCK75 PTPCK95 PTPCK11 $120.00 $94.00 $104.00 Power Take-Off Terminals Terminal Screw Kit Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-49 IEC Power Devices Section 5 IEC Contactor Coils C-2000 AC Coils For Use With Coil Frequency Product Number List Price GO-10C2 AC AC AC LB1A* LB3A* LB4A* $24.00 $33.00 $38.00 CL00, CL01, CL02, CL25 contactors CL04, CL45 contactors CL06, CL07, CL08, CL09, CL10 contactors AC Voltage Selection Note: Frequency/voltage combinations shaded in gray are available by special order only. *AC Voltage 60 Hz 24 48 110 120 208 220 277 240 380 440 480 600 — Designation Letter C F H J L M N S T V U Y — *AC Voltage 50 Hz 24 32 42 48 110 127 220/230 240 380/400 415 440 500 660/690 *AC Voltage 50/60 Hz 24 42 110/115 120 220 230 240 440 — — — — — Designation Letter 1 2 3 4 5 6 7 8 — — — — — Coil Frequency Product Number List Price GO-10C2 DC DC LB1D# LB3D# $36.00 $50.00 Designation Letter D E F G J K N R U W X Y Z Coil DC Coils For Use With CL00, CL01, CL02, CL25 contactors CL04, CL45 contactors DC Voltage Selection #DC Voltage 24 36 42 48 60 72 110 120/125 220 250 Designation Letter D E F G H I J K N T To complete coil product number, replace the *, or # with the appropriate “Designation Letter/Digit” (from AC Voltage Selection and DC Voltage Selection tables above) corresponding to the voltage and frequency of the control circuit. Special order coils (shaded in gray): Minimum order, LB1A*: 20 units; all others: 10 units AC/DC Coils For Use With Coil Frequency CL06, CL07, CL08, CL09, CL10 contactors AC/DC Electronic Coil & Module Combination 3-pole CK75C, CK08C contactors AC/DC 3-pole CK75C, CK08C contactors AC/DC 3-pole CK08B, CK09B, CK95B contactors AC/DC 3-pole CK08B, CK09B, CK95B contactors AC/DC 4-pole CK08B, CK09B, CK95B contactors AC/DC 3- and 4-pole CK10B, CK11B and CK12B contactors 4-pole CK08B, CK09B, CK95B contactors AC/DC 3- and 4-pole CK10B, CK11B and CK12B contactors 3- and 4-pole CK10C, CK11C contactors AC/DC 3- and 4-pole CK10C, CK11C contactors AC/DC Item List Price Product Number GO-10C2 LB4E† $80.00 Coils for use w/ electronic module Electronic module Coils for use w/ electronic module Electronic module Coils for use w/ electronic module KB4E† KM4E† KB5E† KM5E† KB6E† $105.00 $195.00 $125.00 $205.00 $220.00 Electronic module KM6E† $240.00 Coils for use w/ electronic module Electronic module KB7E† KM7E† $185.00 $225.00 AC/DC Voltage Selection Note: When assembling a coil for use with an electronic module, the voltage on both the coil and electronic module must be the same. †Voltage 24-48 42-48 110-127 220-250 380-415 440-500 Designation Letter D F J N U Y To complete product numbers, replace the † with the appropriate Designation Letter from AC/DC Voltage Selection table above. Order one coil and one electronic module to function together. Product Number Selection Instructions: See page 5-37 5-50 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactor Enclosures Page Updated 08 / 2013 C-2000 NEMA Enclosures1 Enclosure type NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 1 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 12/3R3 NEMA Type 4 NEMA Type 4 NEMA Type 4 NEMA Type 4 NEMA Type 4 NEMA Type 4 NEMA Type 4 List Price Product Number GO-10C2 For Use With Contactor Size Contactors and Starters, No CPT, Lift-Off Cover Contactors and Starters, No CPT, Lift-Off Cover Contactors and Starters, No CPT, Lift-Off Cover Contactors and Starters, With CPT2, Lift-Off Cover Contactors and Starters, With CPT, Lift-Off Cover Contactors and Starters With CPT2, Lift-Off Cover Reversing Contactors and Starters, Wye-Delta Starters With/ Without CPT2, Hinged Cover Reversing Contactors and Starters With/Without CPT2, Hinged Cover Wye-Delta Starters With/ Without CPT2, Hinged Cover Contactors and Starters No CPT, Lift-Off Cover Contactors and Starters No CPT, Lift-Off Cover Contactors and Starters With CPT Hinged Cover, Reversing Contactors and Starters No CPT, Hinged Cover Contactors and Starters With CPT Hinged Cover, Reversing Contactors and Starters No CPT, Hinged Cover Reversing Contactors and Starters With CPT, Hinged Cover Reversing Contactors and Starters With CPT, Hinged Cover Wye-Delta Starters With/ Without CPT, Hinged Cover Wye-Delta Starters With/ Without CPT, Hinged Cover Contactors and Starters No CPT, Hinged Cover Contactors and Starters No CPT, Hinged Cover Contactors and Starters With CPT Hinged Cover, Reversing Contactors and Starters No CPT, Hinged Cover Contactors and Starters With CPT Hinged Cover, Reversing Contactors and Starters No CPT, Hinged Cover Reversing Contactors and Starters With CPT Hinged Cover, Wye-Delta Starters, With/Without CPT2, Hinged Cover Reversing Contactors and Starters With CPT2, Hinged Cover Wye-Delta Starters With/ Without CPT2, Hinged Cover CL00, CL01, CL02, CL25, CL04, CL45 contactors CL06, CL07, CL08 contactors CLXE1A $42.00 CLXE1B $60.00 CL09, CL10 contactors CLXE1C $96.00 CL00, CL01, CL02, CL25, CL04, CL45 contactors CL06, CL07, CL08 contactors CLXE1D $29.00 CLXE1E $47.00 CL09, CL10 contactors CLXE1F $69.00 CL00, CL01, CL02, CL25, CL04, CL45 contactors CLXE1G $140.00 CL06, CL07, CL08, CL09, CL10 contactors CL06, CL07, CL08, CL09, CL10 contactors CL00, CL01, CL02, CL25, CL04, CL45 contactors CL06, CL07, CL08, CL09, CL10 contactors CL00, CL01, CL02, CL25, CL04, CL45 contactors CLXE1H $192.00 CLXE1L $268.00 CLXE2A $90.00 CLXE2B $122.00 CLXE2C $142.00 CL06, CL07, CL08, CL09, CL10 contactors CLXE2D $168.00 CL00, CL01, CL02, CL25, CL04, CL45 contactors CL06, CL07, CL08, CL09, CL10 contactors CL00, CL01, CL02, CL25, CL04, CL45 contactors CL06, CL07, CL08, CL09, CL10 contactors CL00, CL01, CL02, CL25, CL04, CL45 contactors CL06, CL07, CL08, CL09, CL10 contactors CL00, CL01, CL02, CL25, CL04, CL45 contactors CLXE2E $159.00 CLXE2F $213.00 CLXE2G $211.00 CLXE2H $388.00 CLXE4A $326.00 CLXE4B $346.00 CLXE4C $343.00 CL06, CL07, CL08, CL09, CL10 contactors CLXE4D $478.00 CL00, CL01, CL02, CL25, CL04, CL45 contactors CLXE4E $537.00 CL06, CL07, CL08, CL09, CL10 contactors CL06, CL07, CL08, CL09, CL10 contactors CLXE4F $589.00 CLXE4H $994.00 NEMA Type 1 NEMA Type 12/3R 1Enclosures are suitable for AC controlled contactors, starters and reversers, and wye-delta starters. For devices with front-mounted accessories and DC control, contact GE Customer Service at 1-800-GE-1-STOP. Enclosures are not sized for front-mounted accessories. Includes externally operated reset button kit to be field installed as required. 2Standard capacity (50 VA) product number CR308XT1**A and extra capacity (150 VA) product number CR308XT1**B (listed on page 5-52) 3Type 12/3R enclosures have hole locators for both pilot devices and reset. For 3R, application plug must be removed. Reference Publications Instructions GEH-5521 GEH-5522 GEH-5523 GEH-5524 GEH-5525 GEH-5526 GEH-5527 Rev. 7/13 Prices and data subject to change without notice Enclosures CLXE1G-CLXE1L NEMA 1 Lift-Off Enclosures CLXR11, 12 Reset Push Button CLXR21, CKXR11, 12 Reset Button CLXP-B, C Start/Stop Push Button CL NEMA 12/3R Enclosures CL NEMA 4 Enclosures www.geindustrial.com NEMA Type 4 Control Catalog 5-51 IEC Power Devices Section 5 Contactor Enclosures Accessories C-2000 Enclosure Accessories Enclosure Accessory Type Start-Stop Push Button Without Light Start-Stop Push Button Without Light Start-Stop Push Button Without Light Start/Stop Push Button With Light Start/Stop Push Button With Light Start/Stop Push Button With Light H-O-A Switch H-O-A Switch H-O-A Switch On-off Switch On-off Switch On-off Switch Red Indicating Light Red Indicating Light Red Indicating Light Reset Kit Reset Kit Reset Kit Reset Kit Reset Kit Control Power Transformer (CPT) Control Power Transformer (CPT) For Use With Product Number List Price GO-10C2 CL00, CL01, CL02, CL25, CL04, CL45 starters with or without CPT CL06, CL07, CL08 starters with or without CPT CL09, CL10 starters with or without CPT CL00, CL01, CL02, CL25, CL04, CL45 starters with or without CPT CL06, CL07, CL08 starters with or without CPT CL09, CL10 starters with or without CPT CL00, CL01, CL02, CL25, CL04, CL45 starters with or without CPT CL06, CL07, CL08 starters with or without CPT CL09, CL10 starters with or without CPT CL00, CL01, CL02, CL25, CL04, CL45 starters with or without CPT CL06, CL07, CL08 starters with or without CPT CL09, CL10 starters with or without CPT CL00, CL01, CL02, CL25, CL04, CL45 starters with or without CPT CL06, CL07, CL08 starters with or without CPT CL09, CL10 starters with or without CPT CL00-45 Starters with and without CPT, Type 1 (CLXE1A, 1D) CL05-10 Starters, CL00-10 Reverser and Wye-Delta Type 1 (CLXE1B-1C, CLXE1E-1L) CL00-10 Starters, Reverser and Wye-Delta Type 12/3R and 4 (CLXE2A-2H, CLXE4A-4H) CK75-12 Starters, Reverser and Wye-Delta Type 1 CK75-12 Starter, Reverser and Wye-Delta Type 12/3R and 4 Standard capacity (50 VA) Extra capacity (150 VA) CLXP1B $39.00 CLXP2B $39.00 CLXP3B $39.00 CLXP1C* $112.00 CLXP2C* $112.00 CLXP3C* $112.00 CLXP1D $39.00 CLXP2D $39.00 CLXP3D $39.00 CLXP1E $39.00 CLXP2E $39.00 CLXP3E $39.00 CLXP1F $67.00 CLXP2F $67.00 CLXP3F $67.00 CLXR11 $8.00 CLXR12 $8.00 CLXR21 $8.00 CKXR11 $10.00 CKXR12 $10.00 Start/Stop Push Button without Light Start/Stop Push Button with Light H-O-A Switch On-Off Switch CR308XT1**A CR308XT1**B $108.00 $180.00 Replace asterisk (*) in product number for Start/Stop Push Button With Light with appropriate voltage code. Voltage Selection* *Code 1 2 4 5 Voltage 115 Volts 230 Volts 460 Volts 575 Volts Red Indicating Light **To complete product number, replace ** with the appropriate digits from below: Control Power Transformer Voltage Selection** Digit 04 05 23 Voltage Dual Primary Reconnectable 220/230/240 and 440/460/480 Volt Primary, 110/115/120 Volt Secondary 550/575/600 Volt Primary, 110/115/120 Volt Secondary 200/208 Volt Primary, 115/120 Volt Secondary Frequency 60 Hz Reset Kit 60 Hz 60 Hz Reference Publications Instructions GEH-5521 GEH-5522 GEH-5523 GEH-5524 GEH-5525 GEH-5526 GEH-5527 Enclosures CLXE1G-CLXE1L NEMA 1 Lift-Off Enclosures CLXR11, 12 Reset Push Button CLXR21, CKXR11, 12 Reset Button CLXP-B, C Start/Stop Push Button CL NEMA 12/3R Enclosures CL NEMA 4 Enclosures Control Power Transformer Product Number Selection Instructions: See page 5-37 5-52 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays C-2000 Overload Relays Fixed Heater C2000 RT overload relays provide motor overload protection through fixed bimetal heaters. These relays are ambient compensated and utilize a differential mechanism for single-phase sensitivity. The trip setting is adjustable for the range listed. Overload relays may be set for 4 different operational modes—manual reset only, automatic reset only, manual reset/stop, or automatic reset/stop. Stop is initiated by pushing the reset button which interrupts the holding circuit in the latter two listed modes. Overload relays feature visible trip indication, reset on the upstroke, weld check, and trip test. RT1 Overload Relay Reference Publications Instructions GEH-6237 DEH-040 GEH-6238 DEH-041 GEH-6239 DEH-042 GEH-6240 GEH-6241 GEH-5520 DEH-055 RT1* (Class 10) Overload RT12* (Class 20) Overload RT2* (Class 10) Overload RT22* (Class 20) Overload RT3* (Class 10) Overload RT32* (Class 20) Overload RT4* (Class 10, 30) Overload RT5* (Class 10, 30) Overload RT5 Overload Connection Kit Remote Electrical Reset RT2 Overload Relay RT3 Overload Relay RT4 Overload Relay RT5 Overload Relay Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-53 IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays C-2000 RT1 - Direct Mount Manual Overload Relay for use with Contactors1 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL01, CL02, CL25, CL04, CL45 CL02, CL25, CL04, CL45 CL25, CL04, CL45 CL04, CL45 CL04, CL45 CL45 Current Range Amps (min-max) Reset Type Trip Class Maximum Fuse Rating Amps Maximum Circuit Breaker Rating Amps 0.16-0.26 0.25-0.41 0.4-0.65 0.65-1.1 1-1.5 1.3-1.9 1.8-2.7 2.5-4.1 4-6.3 5.5-8.5 8.0-12.0 10.0-16.0 14.5-18 17.5-22 21-26 25-32 30-40 Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 1 1 3 6 6 6 10 15 20 25 40 50 60 70 80 100 100 15 15 15 15 15 15 15 15 15 15 30 35 40 50 60 80 80 Product Number RTN1B RTN1C RTN1D RTN1F RTN1G RTN1H RTN1J RTN1K RTN1L RTN1M RTN1N RTN1P RTN1S RTN1T RTN1U RTN1V RTN1W List Price GO-10C2 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $57.00 $57.00 $57.00 $57.00 $57.00 $57.00 $65.00 $78.00 RT1 - Direct Mount Manual/Auto Overload Relay for use with Contactors1 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL01, CL02, CL25, CL04, CL45 CL02, CL25, CL04, CL45 CL25, CL04, CL45 CL04, CL45 CL04, CL45 CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL00, CL01, CL02, CL25, CL04, CL45 CL01, CL02, CL25, CL04, CL45 CL02, CL25, CL04, CL45 CL25, CL04, CL45 CL04, CL45 CL04, CL45 CL45 Current Range Amps (min-max) Reset Type Trip Class Maximum Fuse Rating Amps Maximum Circuit Breaker Rating Amps Product Number List Price GO-10C2 0.16-0.26 0.25-0.41 0.4-0.65 0.65-1.1 1-1.5 1.3-1.9 1.8-2.7 2.5-4.1 4-6.3 5.5-8.5 8.0-12.0 10.0-16.0 14.5-18 17.5-22 21-26 25-32 30-40 0.4-0.65 0.65-1.1 1-1.5 1.3-1.9 2.5-4.1 4-6.3 5.5-8.5 8.0-12.0 10.0-16.0 14.5-18 17.5-22 21-26 25-32 30-40 Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 1 1 3 6 6 6 10 15 20 25 40 50 60 70 80 100 100 3 6 6 6 15 20 25 40 50 60 70 80 100 100 15 15 15 15 15 15 15 15 15 15 30 35 40 50 60 80 80 15 15 15 15 15 15 15 30 35 40 50 60 80 80 RT1B RT1C RT1D RT1F RT1G RT1H RT1J RT1K RT1L RT1M RT1N RT1P RT1S RT1T RT1U RT1V RT1W RT12D RT12F RT12G RT12H RT12K RT12L RT12M RT12N RT12P RT12S RT12T RT12U RT12V RT12W $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $57.00 $57.00 $57.00 $57.00 $57.00 $57.00 $65.00 $78.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $57.00 $57.00 $57.00 $57.00 $57.00 $57.00 $65.00 $78.00 1Do not exceed contactor current rating when selecting and adjusting overload relays. For panel mount use base adapter RTXP. Product Number Selection Instructions: See page 5-37 5-54 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays C-2000 RT2 - Direct Mount Manual Overload Relay for use with Contactors1 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL07, CL08, CL09, CL10 CL08, CL09, CL10 CL10 CL10 Current Range Amps (min-max) Reset Type Trip Class Maximum Fuse Rating Amps Maximum Circuit Breaker Rating Amps Product Number List Price GO-10C2 11.5-15 14.5-19 18.5-25 24-32 30-43 42-55 54-65 64-82 78-97 90-110 Manual Manual Manual Manual Manual Manual Manual Manual Manual Manual Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 35 50 70 90 100 150 175 225 225 225 25 45 60 80 100 125 150 200 225 250 RTN2A RTN2B RTN2C RTN2D RTN2E RTN2G RTN2H RTN2J RTN2L RTN2M $98.00 $98.00 $98.00 $98.00 $98.00 $98.00 $98.00 $117.00 $143.00 $143.00 Product Number List Price GO-10C2 RT2 - Direct Mount Manual/Auto Overload Relay for use with Contactors1 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL07, CL08, CL09, CL10 CL08, CL09, CL10 CL10 CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL06, CL07, CL08, CL09, CL10 CL07, CL08, CL09, CL10 CL08, CL09, CL10 CL10 CL10 Current Range Amps (min-max) Reset Type Trip Class Maximum Fuse Rating Amps Maximum Circuit Breaker Rating Amps 11.5-15 14.5-19 18.5-25 24-32 30-43 42-55 54-65 64-82 78-97 90-110 24-32 30-43 42-55 54-65 64-82 78-97 90-110 Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Manual/Auto w/wo stop Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 Class 20 35 50 70 90 100 150 175 225 225 225 90 100 150 175 225 225 225 25 45 60 80 100 125 150 200 225 250 80 100 125 150 200 225 250 RT2A RT2B RT2C RT2D RT2E RT2G RT2H RT2J RT2L RT2M RT22D RT22E RT22G RT22H RT22J RT22L RT22M $98.00 $98.00 $98.00 $98.00 $98.00 $98.00 $98.00 $117.00 $143.00 $143.00 $98.00 $98.00 $98.00 $98.00 $117.00 $143.00 $143.00 1Do not exceed contactor current rating when selecting and adjusting overload relays. For panel mount use base adapter RT2XP. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-55 IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays C-2000 RT3 - Direct or Panel Mount Overload Relay for use with Contactors1 CK75, CK08 CK75, CK08 CK75, CK08 CK75, CK08 CK08 CK75, CK08 CK75, CK08 CK75, CK08 CK75, CK08 CK08 CK75, CK08 CK75, CK08 CK75, CK08 CK08 Current Range Amps (min-max) Reset Type Trip Class Maximum Fuse Rating Amps Maximum Circuit Breaker Rating Amps Product Number List Price GO-10C2 55-80 63-90 90-120 110-140 140-190 55-80 63-90 90-120 110-140 140-190 63-90 90-120 110-140 140-190 Manual Manual Manual Manual Manual Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 20 Class 20 Class 20 Class 20 225 250 350 400 450 225 250 350 400 450 250 350 400 450 200 225 300 350 500 200 225 300 350 500 225 300 350 500 RTN3B RTN3C RTN3D RTN3E RTN3F RT3B RT3C RT3D RT3E RT3F RT32C RT32D RT32E RT32F $185.00 $185.00 $185.00 $225.00 $225.00 $185.00 $185.00 $185.00 $225.00 $225.00 $185.00 $185.00 $225.00 $225.00 1Do not exceed contactor current rating when selecting and adjusting overload relays. RT4 - Separate Mount Overload Relay for use with Contactors1 CK09, CK95 CK09, CK95 CK95 CK09, CK95 CK09, CK95 CK95 CK09, CK95 CK09, CK95 CK09, CK95 CK09, CK95 CK09, CK95 CK95 Current Range Amps (min-max) Reset Type Trip Class Terminal Type 120-190 175-280 200-310 120-190 175-280 200-310 45-70 60-90 80-125 120-190 175-280 200-310 Manual Manual Manual Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 30 Class 30 Class 30 Class 30 Class 30 Class 30 Bus bar2 Bus bar2 Bus bar2 Bus bar2 Bus bar2 Bus bar2 Clamp Clamp Clamp Bus bar2 Bus bar2 Bus bar2 Maximum Fuse Maximum Circuit Breaker Rating Amps Rating Amps Product Number 600 800 900 600 800 900 225 300 400 600 800 900 500 700 800 500 700 800 175 225 350 500 700 800 RTN4N RTN4P RTN4R RT4N RT4P RT4R RT4LK RT4LL RT4LM RT4LN RT4LP RT4LR List Price GO-10C2 $285.00 $285.00 $380.00 $285.00 $285.00 $380.00 $285.00 $285.00 $285.00 $285.00 $285.00 $380.00 1Do not exceed contactor current rating when selecting and adjusting overload relays. 2Can be mounted to contactor with Overload Jumpers (listed on page 5-47) and Base Plate (CKXB01) (listed on page 5-47). RT5 - Separate Mount2 Overload Relay for use with Contactors1 CK10, CK11, CK12 CK10, CK11, CK12 CK10, CK11, CK12 CK10, CK11, CK12 CK11, CK12 4 CK10, CK11, CK12 CK10, CK11, CK12 CK10, CK11, CK12 CK10, CK11, CK12 CK11, CK12 4 CK10, CK11, CK12 CK10, CK11, CK12 CK10, CK11, CK12 CK10, CK11, CK12 CK11, CK12 Current Range Amps (min-max) Reset Type Trip Class Maximum Fuse Rating Amps Maximum Circuit Breaker Rating Amps Product Number List Price GO-10C2 120-190 175-280 250-400 315-500 30-650 120-190 175-280 250-400 315-500 30-650 120-190 175-280 250-400 315-500 430-650 Manual Manual Manual Manual Manual Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Manual/Auto Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 10 Class 30 Class 30 Class 30 Class 30 Class 30 800 1200 1200 1200 1200 800 1200 1200 1200 1200 800 1200 1200 1200 1200 500 700 1000 1200 1200 500 700 1000 1200 1200 500 700 1000 1200 1200 RTN5A RTN5B3 RTN5C3 RTN5D3 RTN5E3 RT5A RT5B3 RT5C3 RT5D3 RT5E3 RT5LA RT5LB RT5LC RT5LD RT5LE $641.00 $641.00 $641.00 $903.00 $903.00 $641.00 $641.00 $641.00 $903.00 $903.00 $641.00 $641.00 $641.00 $903.00 $903.00 1Do not exceed contactor current rating when selecting and adjusting overload relays. 2Can be mounted to contactor with Overload Jumpers (listed on page 5-47). 3Maximum fuse rating of 1000 amps/maximum circuit breaker rating of 600 amps when used with CK10CE or CK11CE contactors. Use CK10BE or CK11BE with higher rated protective devices indicated. CK12BE suitable for all ratings listed. Product Number Selection Instructions: See page 5-37 5-56 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays Accessories C-2000 Remote Electrical Reset Remote electrical resets are used in applications where the motor starter is inaccessible or in automated control systems where it is required to reset the overload relay remotely after the fault has been cleared. Electrical reset coils are rated for intermittent duty and for use with momentary contacts. Minimum time .2 sec. on for reliable operation. Maximum time 1 sec. on/30 sec. off, 5 sec. on/90 sec. off, 10 sec. on/180 sec. off. Power consumption is 100VA/100 watts. For Use With Voltage 50/60 Hz AC or DC All RT overload relays All RT overload relays All RT overload relays All RT overload relays All RT overload relays All RT overload relays All RT overload relays 12 24 48 110-120 220-240 380-415 440-480 Product Number RTXRRB RTXRRD RTXRRG RTXRRJ RTXRRN RTXRRU RTXRRX List Price GO-10C2 RTXRR_ _Remote Electrical Reset $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 $55.00 Overload Base Adapter Permits mounting of RT1 or RT2 overload on panel or DIN rail. For Use With Product Number List Price GO-10C2 RTXP RT2XP $12.00 $24.00 RT1 RT2 RT_ _ _Overload Base Adapter Transparent Cover for Range Adjustment Dial Deters tampering with dial. For Use With Product Number List Price GO-10C2 RTX31 $19.00 All Overload Relays 1Product number represents a quantity of 10 pieces. Locking Plug for Manual/Auto Selector RTX3 Transparent Cover Prevents changing reset mode after installation. For Use With Product Number List Price GO-10C2 RTXL1 $10.00 All Overload Relays 1Product number represents a quantity of 10 pieces. Flexible Cable Reset Button Allows manual reset of overload when overload is mounted in a special or inaccessible position. Fits standard 22.5 mm panel hole. For Use With Cable Length Product Number List Price GO-10C2 All Overloads All Overloads .5 meter 1.0 meter RTXR RTXRL $55.00 $80.00 RTXL Locking Plug RTXR Flexible Cable Reset Button Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-57 IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays Technical Characteristics C-2000 Class 10 RT1 Class 20 RT12 Class 10 RT2 Class 20 RT22 Class 10 RT3 Class 20 RT32 Product Number Selection Instructions: See page 5-37 5-58 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Thermal Overload Relays Technical Characteristics C-2000 Rev. 7/13 Prices and data subject to change without notice RT4 RT4L RT5 RT5L www.geindustrial.com Control Catalog 5-59 IEC Power Devices Section 5 IEC Control Relays Selection Guide C-2000 AC Operated Standard Terminals Contact Configuration Product Number 4NO 3NO-1NC 2NO-2NC 4NC RL4RA040T* RL4RA031T* RL4RA022T* RL4RA004T* List Price GO-10C2 $57.00 $57.00 $57.00 $57.00 AC Operated with Ring Terminal Capacity Contact Configuration Product Number 4NO 3NO-1NC 2NO-2NC 4NC RL4RA040R* RL4RA031R* RL4RA022R* RL4RA004R* List Price GO-10C2 $65.00 $65.00 $65.00 $65.00 To complete the product number, replace the asterisk (*) with the appropriate digit from the Coil Selection table. Contact Rating: A600, P600. AC Coil Selection Control Relay Control Terminal Relay Markings AC Voltage 60 Hz 24 48 120 208 277 240 480 — 600 50 Hz 24 42 110 — 220/230 — 380/400 415 500 * Coil Suffix 1 F J L N S U W Y RL4R_040_ RL4R_031_ DC Operated Standard Terminals Contact Configuration 4NO 3NO-1NC 2NO-2NC 4NC RL4R_022_ Product Number List Price GO-10C2 RL4RD040T# RL4RD031T# RL4RD022T# RL4RD004T# $100.00 $100.00 $100.00 $100.00 RL4R_004_ DC Operated with Ring Terminal Capacity Contact Configuration 4NO 3NO-1NC 2NO-2NC 4NC Product Number List Price GO-10C2 RL4RD040R# RL4RD031R# RL4RD022R# RL4RD004R# $108.00 $108.00 $108.00 $108.00 To complete the product number, replace the crosshatch (#) with the appropriate digit from the Coil Selection table. Contact Rating: A600, P600. DC Coil Selection DC Voltage 12 24 48 125 250 #Coil Suffix B D G K T Reference Publications Instructions GEH-6248 RL Relay Product Number Selection Instructions: See page 5-37 5-60 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Control Relays Accessories C-2000 Front-Mount Auxiliary Contact Blocks Front-mount auxiliary contact blocks clip onto front face of relay. Contact Rating: A600, Q600. For Use With RL Control Relays RL Control Relays RL Control Relays RL Control Relays RL Control Relays RL Control Relays 1Overlapping contacts. Terminal Type Contact Configuration Product Number List Price GO-10C2 Standard Standard Standard Standard Ring Ring 1NO 1NC 1NO 1NC 1NO 1NC BCLF10 BCLF01 BCLF10G1 BCLF01G1 BCRF10 BCRF01 $11.00 $11.00 $15.00 $15.00 $13.00 $13.00 Front-Mounted Block BCLF10/BCLF01/BCLF10G/BCLF01G Side-Mount Auxiliary Contact Blocks Side-mount auxiliary contact blocks can be mounted on either left or right sides of relay. Positive displacement contacts are designed to prevent simultaneous closing of NO and NC contacts to avoid overlapping between opposing functions. Contact Rating: A600, Q600. For Use With Terminal Type Type Contact Configuration Product Number List Price GO-10C2 Standard Standard Adder Block Adder Block 1NO-1NC 2NO BRLL11 BRLL20 $19.00 $19.00 RL4 Control Relays RL4 Control Relays BCRF10/BCRF01 Pneumatic Timer Pneumatic timers are adjustable time-delayed auxiliary contacts. They come equipped with two time-delayed contacts: 1NO and 1NC, electrically isolated. Setting is scaled over a 350° rotation by means of a knurled knob with timing guide marks. To mount a pneumatic timer, simply clip it on front face of contactor. Contact Rating: A600, Q600. For Use With Terminal Type Type Time range Contact Configuration Product Number List Price GO-10C2 Standard Standard Standard Standard Ring Ring Ring Ring Time Delay On Time Delay On Time Delay Off Time Delay Off Time Delay On Time Delay On Time Delay Off Time Delay Off 1-30 sec 1-60 sec 1-30 sec 1-60 sec 1-30 sec 1-60 sec 1-30 sec 1-60 sec 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC 1NO-1NC BTLF30C BTLF60C BTLF30D BTLF60D BTRF30C BTRF60C BTRF30D BTRF60D $120.00 $120.00 $120.00 $120.00 $124.00 $124.00 $124.00 $124.00 RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays Side-Mounted Block BRLL11/BRLL20 Pneumatic Timer BTRF30C/BTRF60C/BTRF30D/BTRF60D BTLF30C/BTLF60C BTLF30D/BTLF60D Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-61 IEC Power Devices Section 5 IEC Control Relays Accessories C-2000 Surge Suppressor For suppression of disturbances in circuit voltage occurring upon opening of the relay. Mounts directly on the top of the coil. For Use With RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays Terminal Type Surge Suppressor Type Voltage Product Number List Price GO-10C2 Standard and Ring Standard and Ring Standard and Ring Standard and Ring Standard and Ring Standard and Ring Standard and Ring Standard and Ring RC RC RC Diode Varistor Varistor Varistor Varistor 24-48 VAC 50-127 VAC 130-240 VAC 12-600 VDC 24-48 VAC, DC 50-127 VAC, DC 130-250 VAC, DC 380-500 VAC, DC BSLR2G BSLR2K BSLR2R BSLDZ BSLV3G BSLV3K BSLV3R BSLV3U $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $32.00 BSL_ _ _Surge Suppressor Mechanical Latch Block Mechanical latch block is used to convert a standard relay into a latched relay. Easy to mount, it clips onto front face of contactor. Contact Rating: A600, Q600. For Use With RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays RL4 Control Relays Terminal Type Voltage Application Coil Voltage Range Product Number List Price GO-10C2 Standard Standard Standard Standard Standard Standard 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 50/60 Hz and DC 24-32 Vdc 42-48 Vdc 110-125 Vdc 208-277 Vdc 380-480 Vdc 500-600 Vdc RMLFD RMLFG RMLFJ RMLFN RLMFU RMLFY $70.00 $70.00 $70.00 $70.00 $70.00 $70.00 BSLR _ _RC A1 + A2 BSLDZ Diode BLSV_ _Varistor RMLF_Mechanical Latch Block RMLF_ Product Number Selection Instructions: See page 5-37 5-62 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Control Relays Accessories C-2000 Electronic Timer and Interface Modules These modules add flexibility to C-2000 relays, providing time-delay functions, and interface for low voltage PLC applications or contactor-mounted manual-auto functions. Easily installed, these modules plug right into the contactor coil terminals. All modules include a status indicating LED and accept plug-in voltage surge suppressors. Timers Time-on delay and time-off delay modules for sequencing control of contactors. They deliver high repeatability, ±3% in ambient temperatures from 32° to 104°F. A red LED provides indication during time-delay operation. Type Time-Delay Range Product Number List Price GO-10C2 On delay On delay Off delay Off delay 0.1-2 s 1.5-45 s 0.1-2 s 1.5-45 s BETL02C BETL45C BETL02D BETL45D $75.00 $75.00 $85.00 $85.00 For Use With All RL4 Control Relays All RL4 Control Relays All RL4 Control Relays All RL4 Control Relays BETL_ _ _Timer Interface Modules Interface modules allow relay operation from 24 Volt or 48 Volt sources (such as a PLC output). Current consumption is 15 mA @ 24 Vdc and 25 mA @ 48 Vdc. A red LED provides indication when voltage is applied to E1-E2. For Use With All RL4 Control Relays All RL4 Control Relays All RL4 Control Relays All RL4 Control Relays All RL4 Control Relays Input Voltage Type Product Number List Price GO-10C2 24 VDC 48 VDC 24 VDC 48 VDC 5-30 VDC Relay Relay Relay with manual override switch Relay with manual override switch Solid State (optical isolation) IMRD IMRG IMRFD IMRFG IMSSD $50.00 $50.00 $65.00 $65.00 $60.00 IM_ _Interface Module Auto-Manual-Stop Modules Auto-Manual-Stop modules allow local and/or remote operation of the relay coil. The Auto-Manual switch selects the input connected to the coil circuit—A1 for automatic or remote operation, B1 for local operation. In both connections, the manual On-Off switch is in series and controls power to the coil. Auto-Manual can be switched only when the On-Off switch is in the Off position. A red LED provides indication when the coil is energized. For Use With Product Number List Price GO-10C2 IMAMS $32.00 All RL4 Control Relays IMAMS Auto-Manual-Stop Module Voltage Surge Suppressors Voltage surge suppressors plug into timer, interface, or auto-stop-manual modules. Coil Voltage Surge Suppressor Type 24-48 VAC 50-127 VAC 130-240 VAC 24-48 VAC 50-127 VAC 130-240 VAC 24-250 VAC 24-48 VAC or DC 50-127 VAC or DC 130-240 VAC or DC Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Resistive/Capacitive (R/C) Diode Varistor Varistor Varistor Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Product Number IMRC2G IMRC2K IMRC2R IMRC3G IMRC3K IMRC3R IMD1Z IMV3G IMV3K IMV3R List Price GO-10C2 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 $24.00 IM_ _ _Voltage Surge Suppressor Control Catalog 5-63 IEC Power Devices Section 5 Specifications C-2000 Contactors, Starters and Relays Mounting Position—3-Pole and 4-Pole CL Contactors (5-75 Hp) and RL4 Relays Standards And Listings To maintain operating integrity, the contactor must be mounted in one of the positions shown below: —IEC 947-1 —BS 5424 —IEC 947-4 —BS 775 —EN 50005 —IEC 158-1 —CEI 17-3/252 —UNE 20109 —CENELEC HD419 —ASE 1025 —VDE 0660/102 —NFC 63-110 —UL 508, cUL —CE Mark —ZH1/457 (Positive Guided Contacts) Pending Standards And Listings —SEMKO, NEMKO, DEMKO, Lloyds Register Ambient Temperature Operating Storage –13° to +131°F/–25° to +55°C 58° to +176°F/50° to 80°C 3-Pole and 4-Pole CK Contactors (100-55 Hp) The contactor must be installed vertically or tilted a maximum of 30° from vertical, as shown below: Altitude Derating Up to 10,000 ft. (3,000 m) 10,000 to 13,200 ft. (3,000 to 4,000 m) 13,2000 to 16,000 ft. (4,000 to 5,000 m) Nominal Values 90% rated current 80% rated current Rated Insulation Voltage —600 Vac. UI = 1000V (per IEC 947) Overload Relays Mounting Positions 5-64 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Technical Data C-2000 CL/CK Contactors Main Contacts Continuous Amp Rating (UL508) AC-1 Amps (IEC 947) AC-2/AC3 FLA (max) 200 Volts 460 Volts 575 Volts 115 Volts 230 Volts 200 Volts 230 Volts 460 Volts 575 Volts 380/400 Volts 380/400 Volts 200 Volts 230 Volts 460 Volts 575 Volts AC-1 < 300 ops/hour AC-1 < 600 ops/hour AC-1 < 1200 ops/hour AC-1 3000 ops/hour AC-3 < 300 ops/hour AC-3 < 600 ops/hour AC-3 < 1200 ops/hour AC-3 3000 ops/hour AC-4 200 ops/hour max AC-4 300 ops/hour max AC-4 360 ops/hour max AC-2/AC-3 HP(max) 1 Phase AC-2/AC-3 HP(max) 3 Phase AC2/3 kW AC2/3 Amps IEC 947 AC-4 HP (max) 3 Phase Maximum Operational Current 460V and below Wire size - Power Terminals 75C(Cu) Torque (Main) in.-lb. Terminal Type Terminal Hole (Contactor Bar) Noise Coil and Switching Data Coil Burden Inrush (AC Voltage) Holding (AC Voltage) Inrush (DC Voltage) Holding (DC Voltage) Inrush (AC/DC Module) Holding (AC/DC Module) AC Voltage DC Voltage AC/DC Module AC Voltage DC Voltage AC/DC Module AC Voltage (at rated voltage) AC Voltage (at +10% to -20%) DC Voltage (at rated voltage) DC Voltage (at +10% to -20%) AC/DC Module (at rated voltage) AC/DC Module (at +10% to -20%) AC Voltage (at rated voltage) AC Voltage (at +10% to -20%) DC Voltage (at rated voltage) DC Voltage (at +10% to -20%) AC/DC Module (at rated voltage) AC/DC Module (at +10% to -20%) AC Voltage (No Load) AC Voltage (Rated Load -AC1, AC3) AC Voltage (Rated Load -AC4) DC Voltage (No Load) DC Voltage (Rated Load -AC1, AC3) DC Voltage (Rated Load -AC4) AC/DC(Module) Voltage (No Load) AC/DC(Module) Module (Rated Load -AC1, AC3) AC/DC(Module) Module (Rated Load -AC4) Pick-up (% coil voltage) Drop-out (% coil voltage) Switching Delay ON (ms) Switching Delay OFF (ms) Maximum Operations per Hour Mechanical Life (millions of Operations) Aux. Contacts Std Product Aux. Contacts Rev. 7/13 Prices and data subject to change without notice Diameter Bolt Size dba Rating A600, Q300 Maximim Number of Aux. Contacts Maximum Aux. Block Configuration www.geindustrial.com CL00A310**, CL00D310**, LAR00A*, LDR00A* CL01A310**, CL01D310**, LAR01A*, LDR01A* CL02A310**, CL02D310**, LAR02A*, LDR02A* CL25A310**, CL25D310**, LAR25A*, LDR25A* CL04A310**, CL04D310**, LAR04A*, LDR04A* CL45A310**, CL45D310**, LAR45A*, LDR45A* 25 25 10 10 10 0.5 1.5 3 3 5 7.5 4 9 3 3 5 7.5 25 25 25 12.5 10 10 10 3.5 10 10 10 14-10 AWG 25 25 13.8 13.8 13.8 0.75 2 3 3 7.5 10 5.5 12 3 3 7.5 10 25 25 25 12.5 13.8 13.8 13.8 4.8 13.8 13.8 13.8 14-10 AWG 32 32 17.5 17.5 17.5 1 3 5 5 10 15 7.5 18 5 5 10 15 32 32 32 16 17.5 17.5 17.5 6.1 17.5 17.5 17.5 14-10 AWG 32 45 22 22 17.5 1.5 3 5 7.5 15 15 11 25 5 7.5 15 15 32 32 32 16 22 22 22 7.7 22 22 22 14-10 AWG 54 60 32 32 32 2 5 10 10 20 25 16 32 10 10 20 25 54 54 54 27 32 32 32 11.2 32 32 32 14-10 AWG 55 60 34 34 27 3 5 10 10 25 25 18.5 40 10 10 25 25 55 55 55 27.5 34 34 34 11.9 34 34 34 14-10 AWG 15 Clamp 15 Clamp 15 Clamp 20 Clamp 16 Clamp 16 Clamp 25 25 25 25 25 35 45 va 6 va 5.5 w 5.5 w 45 va 6 va 5.5 w 5.5 w 45 va 6 va 5.5 w 5.5 w 45 va 6 va 5.5 w 5.5 w 88 va 9 va 7.5 w 7.5 w 88 va 9 va 7.5 w 7.5 w 85-110 80-110 40-55 20-40 8-20 6-25 40-50 35-65 6-13 6-13 30-60 30-60 9000 1200 360 3600 1200 360 20 1NO (Built-in) 4 4 front or 1 side-mount each side 85-110 80-110 40-55 20-40 8-20 6-25 40-50 35-65 6-13 6-13 30-60 30-60 9000 1200 360 3600 1200 360 20 1NO (Built-in) 4 4 front or 1 side-mount each side 85-110 80-110 40-55 20-40 8-20 6-25 40-50 35-65 6-13 6-13 30-60 30-60 9000 1200 360 3600 1200 360 20 1NO (Built-in) 4 4 front or 1 side-mount each side 85-110 80-110 40-55 20-40 8-20 6-25 40-50 35-65 6-13 6-13 30-60 30-60 9000 1200 360 3600 1200 360 20 1NO Front 4 4 front or 1 side-mount each side 85-110 80-110 40.55 15-30 10-19 7-25 40-65 35-70 5-25 5-25 40-65 40-65 9000 1200 360 3600 1200 360 20 1NO (Built-in) 6 4 front plus 1 side or 2 front plus 1 side mount each side 85-110 80-110 40.55 15-30 10-19 7-25 40-65 35-70 5-25 5-25 40-65 40-65 9000 1200 360 3600 1200 360 20 1NO Front 6 4 front plus 1 side or 2 front plus 1 side mount each side Control Catalog 5-65 IEC Power Devices Section 5 IEC Contactors Technical Data C-2000 CL/CK Contactors Main Contacts Continuous Amp Rating (UL508) AC-1 Amps (IEC 947) AC-2/AC3 FLA (max) 200 Volts 460 Volts 575 Volts 115 Volts 230 Volts 200 Volts 230 Volts 460 Volts 575 Volts 380/400 Volts 380/400 Volts 200 Volts 230 Volts 460 Volts 575 Volts AC-1 < 300 ops/hour AC-1 < 600 ops/hour AC-1 < 1200 ops/hour AC-1 3000 ops/hour AC-3 < 300 ops/hour AC-3 < 600 ops/hour AC-3 < 1200 ops/hour AC-3 3000 ops/hour AC-4 200 ops/hour max AC-4 300 ops/hour max AC-4 360 ops/hour max AC-2/AC-3 HP(max) 1 Phase AC-2/AC-3 HP(max) 3 Phase AC2/3 kW AC2/3 Amps IEC 947 AC-4 HP (max) 3 Phase Maximum Operational Current 460V and below Wire size - Power Terminals 75C(Cu) Torque (Main) in.-lb. Terminal Type Terminal Hole (Contactor Bar) Noise Coil and Switching Data Coil Burden Inrush (AC Voltage) Holding (AC Voltage) Inrush (DC Voltage) Holding (DC Voltage) Inrush (AC/DC Module) Holding (AC/DC Module) AC Voltage DC Voltage AC/DC Module AC Voltage DC Voltage AC/DC Module AC Voltage (at rated voltage) AC Voltage (at +10% to -20%) DC Voltage (at rated voltage) DC Voltage (at +10% to -20%) AC/DC Module (at rated voltage) AC/DC Module (at +10% to -20%) AC Voltage (at rated voltage) AC Voltage (at +10% to -20%) DC Voltage (at rated voltage) DC Voltage (at +10% to -20%) AC/DC Module (at rated voltage) AC/DC Module (at +10% to -20%) AC Voltage (No Load) AC Voltage (Rated Load -AC1, AC3) AC Voltage (Rated Load -AC4) DC Voltage (No Load) DC Voltage (Rated Load -AC1, AC3) DC Voltage (Rated Load -AC4) AC/DC(Module) Voltage (No Load) AC/DC(Module) Module (Rated Load -AC1, AC3) AC/DC(Module) Module (Rated Load -AC4) Pick-up (% coil voltage) Drop-out (% coil voltage) Switching Delay ON (ms) Switching Delay OFF (ms) Maximum Operations per Hour Mechanical Life (millions of Operations) Aux. Contacts Std Product Aux. Contacts 5-66 Diameter Bolt Size dba Rating A600, Q300 Maximim Number of Aux. Contacts Maximum Aux. Block Configuration Control Catalog CL06A311**, CL06E311**, LAR06A*, LER06A* CL07A311**, CL07E311**, LAR07A*, LER07A* CL08A311**, CL08E311**, LAR08A*, LER08A* CL09A311**, CL09E311**, LAR09A*, LER09A* CL10A311**, CL10E311**, LAR10A*, LER10A* CK75CE311*, KAR75C* 80 80 48 48 48 3 7.5 15 15 30 40 22 50 15 15 30 40 80 80 80 40 48 48 48 16.8 48 48 48 14-10 AWG 100 100 62 62 62 3 7.5 20 20 40 50 30 65 20 20 40 50 100 100 100 50 62 62 62 21.7 62 62 62 14-10 AWG 110(O),102(E) 110 68 68 68 5 15 20 25 50 60 37 80 20 25 50 60 110 110 110 55 68 68 68 23.8 68 68 68 14-10 AWG 140(O),120(E) 140 80 80 80 7.5 15 25 30 60 75 45 95 25 30 60 75 140(O),120(E) 140 104 96 80 10 20 30 40 75 75 55 105 30 40 75 75 150 200 140 140 140 10 25 40 50 100 125 75 150 40 50 100 125 120 96 48 140(O), 120(E) 112(O), 96(E) 56(O), 48(E) 150 125 50 80 60 20 80 10-2/0 AWG 96 72 24 96 10-2/0 AWG 140 100 30 140 6 AWG - 250kcmil 40 Box Lug 40 Box Lug 40 Box Lug 60 Box Lug 60 Box Lug 45 45 45 45 45 275 Optional Lug CKX03 0.32 M-8 45 191 va 17 va 191 va 17 va 191 va 17 va 191 va 17 va 191 va 17 va 125 w 2.5 w 85-110 80-110 40-60 40-60 15-30 9-35 50-60 60-80 9-15 9-15 55-60 40-50 55-60 40-50 9000 1200 200 2500 1200 200 15 1NO, 1NC Front 8 6 front plus 1 side mount or 2 side mount each side 125 w 2.5 w 85-110 80-110 40-60 40-60 15-30 9-35 50-60 60-80 9-15 9-15 55-60 40-50 9000 1200 200 2500 1200 200 15 1NO, 1NC Front 8 6 front plus 1 side mount or 2 side mount each side 125 w 2.5 w 85-110 80-110 40-60 40-60 15-30 9-35 50-60 60-80 9-15 9-15 55-60 40-50 9000 1200 200 2500 1200 200 15 1NO, 1NC Front 8 6 front plus 1 side mount or 2 side mount each side 125 w 2.5 w 85-110 80-110 40-60 40-60 15-30 9-35 55-60 40-50 9-15 9-15 55-60 40-50 5000 1200 200 2500 1200 200 15 1NO, 1NC Front 8 6 front plus 1 side mount or 2 side mount each side 125 w 2.5 w 85-110 80-110 40-60 40-60 15-30 9-35 55-60 40-50 9-15 9-15 55-60 40-50 5000 1200 200 2500 1200 200 15 1NO, 1NC Front 8 6 front plus 1 side mount or 2 side mount each side www.geindustrial.com 350 va 20 va 80-110 40-60 60-70 13-17 1200 600 150 10 1NO,1NC Side 8 2 side mount each side Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Technical Data C-2000 CL/CK Contactors Main Contacts Continuous Amp Rating (UL508) AC-1 Amps (IEC 947) AC-2/AC3 FLA (max) 200 Volts 460 Volts 575 Volts 115 Volts 230 Volts 200 Volts 230 Volts 460 Volts 575 Volts 380/400 Volts 380/400 Volts 200 Volts 230 Volts 460 Volts 575 Volts AC-1 < 300 ops/hour AC-1 < 600 ops/hour AC-1 < 1200 ops/hour AC-1 3000 ops/hour AC-3 < 300 ops/hour AC-3 < 600 ops/hour AC-3 < 1200 ops/hour AC-3 3000 ops/hour AC-4 200 ops/hour max AC-4 300 ops/hour max AC-4 360 ops/hour max AC-2/AC-3 HP(max) 1 Phase AC-2/AC-3 HP(max) 3 Phase AC2/3 kW AC2/3 Amps IEC 947 AC-4 HP (max) 3 Phase Maximum Operational Current 460V and below Wire size - Power Terminals 75C(Cu) Torque (Main) in.-lb. Terminal Type Terminal Hole (Contactor Bar) Noise Coil and Switching Data Coil Burden Inrush (AC Voltage) Holding (AC Voltage) Inrush (DC Voltage) Holding (DC Voltage) Inrush (AC/DC Module) Holding (AC/DC Module) AC Voltage DC Voltage AC/DC Module AC Voltage DC Voltage AC/DC Module AC Voltage (at rated voltage) AC Voltage (at +10% to -20%) DC Voltage (at rated voltage) DC Voltage (at +10% to -20%) AC/DC Module (at rated voltage) AC/DC Module (at +10% to -20%) AC Voltage (at rated voltage) AC Voltage (at +10% to -20%) DC Voltage (at rated voltage) DC Voltage (at +10% to -20%) AC/DC Module (at rated voltage) AC/DC Module (at +10% to -20%) AC Voltage (No Load) AC Voltage (Rated Load -AC1, AC3) AC Voltage (Rated Load -AC4) DC Voltage (No Load) DC Voltage (Rated Load -AC1, AC3) DC Voltage (Rated Load -AC4) AC/DC(Module) Voltage (No Load) AC/DC(Module) Module (Rated Load -AC1, AC3) AC/DC(Module) Module (Rated Load -AC4) Pick-up (% coil voltage) Drop-out (% coil voltage) Switching Delay ON (ms) Switching Delay OFF (ms) Maximum Operations per Hour Mechanical Life (millions of Operations) Aux. Contacts Std Product Aux. Contacts Rev. 7/13 Prices and data subject to change without notice Diameter Bolt Size dba Rating A600, Q300 Maximim Number of Aux. Contacts Maximum Aux. Block Configuration www.geindustrial.com CK08CE311*, KAR08C* CK09BE311*, KAR09B* CK95BE311*, KAR95B* CK10CE311*, KAR10C* CK11CE311*, KAR11C* CK12BE311*, KAR12B* 175 250 156 156 156 15 30 50 60 125 150 90 185 50 60 125 150 200 315 192 192 192 310 500 302 302 302 500 600 398 398 398 600 700 480 480 480 750 (O), 650(E) 1000 602 602 602 60 75 150 150 132 250 60 75 150 150 100 100 250 300 160 310 100 100 250 250 175 140 70 200 160 80 310 250 120 156 115 39 156 6 AWG - 250kcmil 192 144 48 192 6 AWG - 350kcmil 302 227 76 302 6 AWG - 350kcmil 275 Optional Lug CKX03 0.32 M-8 45 200 Optional Lug CKX02 0.43 M-10 45 200 Optional Lug CKX02 0.43 M-10 45 125 150 300 400 220 420 125 150 300 400 500 400 398 299 398 398 2 AWG -500kcmil ; 2/0 AWG -600kcmil 375 Optional Lug CKX01 0.43 M-10 45 150 200 400 500 280 550 150 200 400 500 600 500 480 360 480 480 2 AWG -500kcmil ; 2/0 AWG -600kcmil 375 Optional Lug CKX01 0.43 M-10 45 200 250 500 600 375 700 200 250 500 600 810 648 602 452 602 602 2 AWG -500kcmil ; 2/0 AWG -600kcmil 375 Optional Lug CKX01 0.43 M-10 45 350 va 20 va 425 va 20 va 425 va 20 va 750 va 25 va 750 va 25 va 750 va 25 va 80-110 80-110 80-110 80-110 80-110 80-110 40-60 60-70 13-17 40-60 60-70 13-17 40-60 60-70 13-17 40-60 110-115 70-80 40-60 110-115 70-80 40-60 70-80 70-80 1200 600 150 10 1NO,1NC Side 8 2 side mount each side 1200 600 150 10 1NO,1NC Side 8 2 side mount each side 1200 600 150 10 1NO,1NC Side 8 2 side mount each side 900 300 120 10 1NO,1NC Side 8 2 side mount each side 900 300 120 10 1NO,1NC Side 8 2 side mount each side 900 300 120 10 1NO,1NC Side 8 2 side mount each side Control Catalog 5-67 IEC Power Devices Section 5 IEC Overload Relays Technical Data C-2000 RT Overload Relays RT1 RT2 RT3 RT4 Suffix K-M RT4 Suffix N-R RT5 Trip Class 10/20 10/20 10/20 10/30 10/30 10/30 Contactor Size CL00 CL01 CL02 CL25 CL04 CL45 CL06 CL07 CL08 CL09 CL10 CK75 CK08 CK09 CK95 CK09 CK95 CK10 CK11 CK12 Rated Insulation Voltage 690V 1000V 1000V 1000V 1000V 1000V Frequency Limits 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz Terminal Capacity 14-8 AWG 14-1/0 AWG 6 AWG-250kcmil 14-2/0 AWG 6 AWG-350kcmil 8 AWG-500 kcmil 2/0 AWG-600 kcmil Terminal Type Clamp Box Optional Lug CKX03 Box Optional Lug CKX02 Optional Lug CKXC01 Torque (in.-lb.) 24-14 50 275 105 200 375 Auxiliary Contact 1NO-1NC B660/Q600 B660/Q600 B660/Q600 B660/Q600 B660/Q600 B660/Q600 Terminal Capacity 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG 7-12 AWG solid or stranded 75°C copper wire 7-12 AWG solid or stranded 75°C copper wire 7-12 AWG solid or stranded 75°C copper wire 7-12 AWG solid or stranded 75°C copper wire 7-12 AWG solid or stranded 75°C copper wire 7-12 AWG solid or stranded 75°C copper wire Terminal Torque (lb.-in.) 5-68 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Accessories Technical Data Full C-2000 Electronic Timer and Interface Modules Wiring Diagrams/Operation Characteristics Standards —UL508, UL listed —cUL listed —IEC 60947-1, 60947-5-1 — Marked, EMC and LV Directives Ambient Temperature Operating Storage –13°F to 140°F –40°F to 176°F Relative Humidity —95% without condensation Wire Size/Torque 14-10 AWG, Cu wire 60°-75°C/Torque 7 lbs./in. Time Delay On Time Delay Off Auto Manual-Stop Interface Module Relay Type Interface Module Relay Type with Manual Switch Interface Module State Type Voltage Input IMRD, IMRFD IMRG, IMRFG IMAMS 17-30 Vdc 33-60 Vdc 5-30 Vdc Switching Rate (200 VA @ 50% PF) —1000 ops/hr Minimum Pulse BETL *D —40ms Electrical Endurance (200 VA @ 50% PF) BETL* IMR*, IMRF* IMSSD IMAMS 15 million operations 3 million operations 15 million operations 10000 cycles Reference Publications Instructions Interface Modules (IMR*, IMRF*, IMSSD, IMAMS) Surge Suppressors (IMRC*, IMDIZ, IMV*) Timers (BETL*) DEH-174 DEH-175 DEH-175 Voltage Standard Contactors Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-69 IEC Power Devices Section 5 IEC Contactors Lifetime Curves C-2000 Utilization Categories Utilization categories are used to describe the type of motor load and duty cycle. Each category has a unique life/load curve which is used to estimate expected electrical life of a specific controller. Following are descriptions of the most common ac utilization categories: Utilization Category AC-1 AC-2 AC-3 AC-4 Description Noninductive or slightly inductive loads, such as resistance furnaces. Starting of slip-ring motors without plugging. Starting and stopping of squirrel-cage motors. This utilization category is typical of the standard type of motor duty encountered in most industrial applications. Starting of squirrel-cage motors in inching, plugging, and reversing applications. Life Curves . . . how to use To determine estimated electrical life for a specific contactor, follow these guidelines: 1. Determine appropriate utilization category. The illustrations below show typical life curves for C-2000 contactors, which will operate the AC-1 utilization categories. AC-2, AC-3, AC-4, and AC-3/AC-4 (mixed-duty) life curves are shown on pages 5-71, 5-72. 2. Once the appropriate utilization category has been determined, then using the appropriate curve, it is easy to determine the expected contactor’s life by reading the figure (in millions of operations) to the left of the intersection of the rated operating current and the contactor curve. Example: Using a motor duty cycle of starting and stopping (standard) for a three-phase squirrel-cage motor rated 15 horsepower at 460 V with an operating current of 19.6 amperes, choose utilization curve AC-3 and take the following action: A. Locate rated operating current on bottom (horizontal) scale and draw a vertical line to intersect the first heavy line which will indicate contactor size. In this example, the drawn vertical line for 19.6 amperes will intersect the CL25 contactor line. B. Reading the vertical scale to the left of the intersection point denotes an expected life of approximately 3 million operations for the selected size of contactor (CL25). C. If greater contactor life is required, continue the drawn vertical line to intersect with a larger size contactor line. Caution note: Do not apply a contactor for use on a motor which has greater horsepower rating than shown in the Data Summary table on pages 5-65 through 5-67. Life Curves AC-1: Noninductive, or lightly inductive loads, e.g., resistance furnaces Product Number Selection Instructions: See page 5-37 5-70 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Lifetime Curves C-2000 AC-2: Starting of Slip-Ring Motors Without Plugging AC-3: Interruption of Running Squirrel-Cage Motors Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-71 IEC Power Devices Section 5 IEC Contactors Lifetime Curves C-2000 AC-4: Inching (Jogging) of Squirrel-Cage Motors AC-3/AC-4: Mixed-Duty with Squirrel-Cage Motors To calculate mixed AC-3/AC-4 life: Find the ratio of AC-3/AC-4 operations on the left side, read across to the appropriate curve for the contactor and breaking current expected (3 times FLA or 6 times FLA). Then read corresponding coefficient from the bottom of the curve. The product of this coefficient and the AC-3 life from the previous page is the expected life under mixed AC-3/AC-4 conditions. Product Number Selection Instructions: See page 5-37 5-72 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Application Ratings-DC C-2000 C-2000 Controls can be used as DC contactors in many industrial applications. These include: DC load banks, loop contactors and dynamic braking contactors in adjustable speed DC drives and other special motor control applications. Contact the motor manufacturer as to the starting requirements of a particular motor. Only small motors can be started at full voltage. Medium and large-sized DC motors require resistance in series with armature during acceleration when connected to a constant potential DC system. AC contactors are conditionally suitable for switching DC. The switching capacity for DC, using AC contactors, is decreased as the voltage increases, and also as inductance is added to the circuit. DC-2 DC-2 applications involve starting and switching off shunt wound DC motors. Shunt wound DC motors are those most frequently used in adjustable voltage, adjustable speed DC drives. Even DC motors with permanent magnet fields are usually considered to be shunt wound. DC-3 DC-3 applications involve starting, stopping, plugging and jogging shunt wound DC motors. Jogging is an inexpensive and frequently ordered DC drive modification. Care must be taken to determine when jogging is required, since it is more severe than duties covered by category DC-2. DC-4 and DC-5 DC-4 and DC-5 applications cover use with series wound, traction-type DC motors. Traction motor requirements are application intensive and should involve factory review. Utilization Categories have been assigned to the more popular loads where contactors are required. They include: DC-1 DC-1 applications involve switching noninductive loads such as resistive load banks. Ratings for DC Applications (AMPS) Rated Voltage Ue Poles in Series CL00 CL01 CL02 CL25 CL04 CL45 CL06 CL07 CL08 CL09 CL10 CK75 CK08 CK09 CK95 CK10 CK11 CK12 24V 1 18 18 18 25 32 40 50 65 65 80 80 200 200 250 350 500 600 800 2 25 25 32 45 60 60 90 110 110 140 140 250 250 315 450 600 700 1000 3 25 25 32 45 60 60 90 110 110 140 140 250 250 315 450 600 700 1000 DC-1 (LR ≤ 15 ms) 125V 4 1 2 3 4 — 6 18 25 — 25 6 18 25 25 32 6 18 25 32 — 8 25 32 — 60 8 45 60 60 — 8 45 60 — — 16 80 90 — 110 16 90 110 110 — 16 90 110 — 140 16 110 140 140 — 16 110 140 — — 25 200 250 — 250 25 200 250 250 315 30 250 315 315 450 50 300 500 500 600 60 400 600 600 700 70 500 700 700 1000 100 600 1000 1000 Single-pole operation Rev. 7/13 Prices and data subject to change without notice 220V 2 3 4 7.5 25 — 7.5 25 25 7.5 25 32 8 32 — 8 50 60 8 50 — 20 90 — 20 110 110 20 110 — 20 140 140 20 140 — 110 250 250 110 250 250 150 315 315 200 500 500 250 600 600 250 700 700 300 1000 1000 440V 3 4 8 — 8 15 8 15 10 — 10 25 10 — 15 — 15 90 15 — 15 110 15 — 120 — 120 200 150 250 180 315 240 400 300 500 400 700 1 12 12 12 18 25 32 40 50 50 65 65 150 185 250 309 420 550 700 24V 2 3 18 18 18 18 18 18 25 25 40 40 40 40 65 65 80 80 80 80 105 105 105 105 150 150 185 185 250 250 309 309 420 420 550 550 700 700 Two poles in series www.geindustrial.com 4 — 18 18 — 40 — — 80 — 105 — — 185 250 309 420 550 700 DC-3 (LR ≤ 2.5 ms) 125V 220V 1 2 3 4 2 3 2 10 15 — 2 12 2 10 15 — 12 15 2 12 18 18 2 12 2 18 25 — 2 18 3 25 32 32 2 25 3 32 40 — 2 32 3 50 65 — 7 50 3 60 80 80 7 65 3 60 80 — 7 65 3 80 105 105 7 95 3 80 105 — 7 95 25 150 150 — 60 150 25 185 185 185 70 185 30 250 250 250 85 250 50 309 309 309 95 309 60 420 420 420 140 420 70 550 550 550 185 550 100 700 700 700 225 700 4 — 6 18 — 32 — — 80 — 150 — — 185 250 309 420 550 700 440V 3 4 1.5 — 1.5 6 1.5 6 1.5 — 3 6 3 — 3 — 3 65 3 — 3 75 3 — 50 — 55 105 70 185 80 205 120 250 150 300 180 400 1 12 12 12 18 25 32 40 50 50 65 65 150 185 250 309 420 550 700 24V 2 3 18 18 18 18 18 18 25 25 40 40 40 40 65 65 80 80 80 80 105 105 105 105 150 150 185 185 250 250 309 309 420 420 550 550 700 700 4 — 18 18 — 32 — — 80 — 105 — — 185 250 309 420 550 700 1 0.8 0.8 0.8 0.8 1.2 1.2 1.2 1.2 1.2 1.2 1.2 20 20 25 40 50 60 80 Three poles in series Control Catalog DC-5 (LR ≤ 15 ms) 125V 220V 2 3 4 2 3 4 5 15 — 0.8 3 — 5 15 15 0.8 3 10 5 15 18 0.8 3 10 5 20 — 0.8 3 — 5 25 32 0.8 3 15 5 32 — 0.8 3 — 50 60 — 3 7 — 60 70 80 3 7 75 60 70 — 3 7 — 85 95 105 4 7 95 85 95 — 4 7 — 95 150 — 50 95 — 105 185 185 55 105 185 185 250 250 70 185 250 205 309 309 80 205 309 250 420 420 120 250 420 300 550 550 150 300 500 400 700 700 180 400 700 440V 3 4 0.5 — 0.5 2 0.5 2 0.5 — 0.7 4 0.7 — 1 — 1 50 1 — 1 60 1 — 40 — 40 95 50 150 60 185 90 205 100 250 100 300 Four poles in series 5-73 IEC Power Devices Section 5 IEC Contactors Application Ratings-AC C-2000 Maximum Three-Phase KVAR Rating for Switching Capacitors Product Number 200V CL00 CL01 CL02 CL25 CL04 CL45 CL06 CL07 CL08 CL09 CL10 CK75 CK08 CK09 CK95 CK10 CK11 CK12 3 4.5 6.5 9 12.5 17 22 25 30 40 50 60 70 95 105 135 190 250 10,000 Amp RMS Maximum Available Fault Current 230V 460V 3 4.5 6.5 9 12.5 17 22 25 30 40 50 60 70 95 105 135 190 250 5 9.5 11 15 21 30 40 45 50 65 80 100 130 165 190 260 325 400 575V 200V 5.7 11 12.5 17.5 24 35 50 65 70 95 120 150 175 230 288 370 450 600 1.5 2.2 3.2 4.5 6.2 8.5 11 12.5 15 20 25 60 70 95 105 135 190 250 22,000 Amp RMS Maximum Available Fault Current 230V 460V 1.5 2.2 3.2 4.5 6.2 8.5 11 12.5 15 20 25 60 70 95 105 135 190 250 575V 2.5 4.5 5.5 7.5 10.5 15 20 22.5 25 32.5 40 100 130 165 190 260 325 400 2.8 5.5 6.2 8.2 12 17.5 25 32.5 35 47.5 60 150 175 230 288 370 450 600 Utilization in Category AC-1, General Use 3-Pole Contactors CL Contactors Max. operational current at ambient 40°C A CK Contactors 00 01 02 25 04 45 06 07 08 09 10 75 08 09 95 10 11 12 25 25 32 32 54 55 80 100 102 120 120 150 175 200 310 500 600 650 temperature of: 55°C A 25 25 32 32 54 55 80 100 102 120 120 150 175 200 310 425 510 546 (for all voltages) 70°C A 20 20 25 25 41 44 62 78 81 80 80 130 155 175 270 335 432 468 4-Pole Contactors CL Contactors Max. operational CK Contactors 01 02 03 04 06 07 08 09 08 09 95 10 11 12 175 200 310 500 550 650 current at ambient 40°C A 25 32 40 54 70 100 110 120 temperature of: 55°C A 25 32 40 54 70 100 110 120 175 200 310 425 462 543 (for all voltages) 70°C A 20 25 28 41 52 78 88 80 155 175 270 335 462 468 UL/cUL Elevator Duty Rating Product Number CL00 CL01 CL02 CL25 CL04 CL06 CL07 CL08 CL09 5-74 Maximum FLA Max Hp (1-phase) 115 Volts HP (A) 230 Volts HP (A) 200 Volts HP (A) Max Hp (3-phase) 230 Volts HP (A) 480 Volts HP (A) 7.8 11 15.2 22 27 34 42 56 65 0.33 (7.2) 0.5 (9.8) 0.75 (13.8) 1.5 (20) 2 (24) 3 (34) 3 (34) 5(56) 5 (56) 0.75 (6.9) 1.5 (10) 2 (12) 3 (17) 3 (17) 5 (28) 7.5 (40) 10 (50 10 (50) 2 (7.8) 3 (11) 3 (11) 5 (17.5) 7.5 (25) 10 (32) 10 (32) 15 (48) 20 (62) 2 (6.8) 3 (9.6) 3 (15.2) 7.5 (22) 7.5 (22) 10 (28) 15 (42) 20 (54) 20 (54) 5 (7.6) 7.5 (11) 10 (14) 15 (21) 20 (27) 25 (34) 30 (40) 40 (52) 50 (65) Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Application Ratings-KVA C-2000 Maximum KVA of Transformer for Primary Switching (50/60 Hz) Product Number CL00 CL00 CL01 CL01 CL02 CL02 CL25 CL25 CL04 CL04 CL45 CL45 CL06 CL06 CL07 CL07 CL08 CL08 CL09 CL09 CL10 CL10 CK75 CK75 CK08 CK08 CK09 CK09 CK95 CK95 CK10 CK10 CK11 CK11 CK12 CK12 Max. Peak Closing Current Phase 120V 208V 450 Amps 450 Amps 450 Amps 450 Amps 450 Amps 450 Amps 550 Amps 550 Amps 550 Amps 550 Amps 550 Amps 550 Amps 1000 Amps 1000 Amps 1000 Amps 1000 Amps 1000 Amps 1000 Amps 1280 Amps 1280 Amps 1280 Amps 1280 Amps 1850 Amps 1850 Amps 1850 Amps 1850 Amps 2500 Amps 2500 Amps 3700 Amps 3700 Amps 7000 Amps 7000 Amps 7000 Amps 7000 Amps 8400 Amps 8400 Amps 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 0.6 1.1 0.8 1.5 1.2 2.2 1.8 3.2 2.2 4.0 2.8 5 3.4 6 4.2 7.5 5.7 10 7.1 12.5 8.5 15 10 17.5 11.4 20 14.2 25 18.5 32 22.8 40 28.5 50 45.7 80 1 1.9 1.4 2.6 2.0 3.8 3.1 5.5 3.8 7.0 4.8 8.6 5.9 10.4 7.2 13 10 17.3 12.3 21.6 14.7 26 17.2 30.3 19.7 34.6 24.6 43.3 32.0 55.4 39.5 69.3 49.4 86.6 79.2 138.6 Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Inrush = 20 x Normal 240V 480V 1.2 2.2 1.7 3.0 2.5 4.5 3.7 6.5 4.5 8.0 5.7 10 6.8 12 8.5 15 11.4 20 14.2 25 17.1 30 20 35 22.8 40 28.5 50 37.1 65 45.7 80 57.1 100 91.4 160 1.7 3.1 2.4 4.2 3.5 6.3 5.2 9.1 6.3 11.2 8.0 14.0 9.5 16.8 12 21 16 28 20 35 24 42 28 49 32 56 40 70 52 91 64 112 80 140 128 224 600V 120V 208V 2.1 3.8 3.0 5.2 4.4 7.7 6.4 11.2 7.8 13.7 9.7 17 12 21 14.2 25 20 35 22.8 40 28.5 50 31.3 55 34.2 60 48.5 85 62.8 110 85.7 150 97.1 170 160 280 0.3 0.5 0.4 0.7 0.6 1.1 0.9 1.6 1.1 2.0 1.4 2.5 1.7 3 2.1 3.7 2.8 5 3.5 6.2 4.2 7.5 5 8.75 5.7 10 7.1 12.5 9.2 16 11.4 20 14.2 25 22.8 40 0.5 0.9 0.7 1.3 1.0 1.9 1.5 2.7 1.9 3.5 2.4 4.3 2.9 5.2 3.6 6.5 5.0 8.6 6.1 10.8 7.3 13 8.6 15.1 9.8 17.3 12.3 21.6 16.0 27.7 19.7 34.6 24.7 43.3 39.6 69.3 Inrush = 40 x Normal 240V 480V 0.6 1.1 0.8 1.5 1.2 2.2 1.8 3.2 2.2 4.0 2.8 5 3.4 6 4.2 7.5 5.7 10 7.1 12.5 8.5 15 10 17.5 11.4 20 14.2 25 18.5 32 22.8 40 28.5 50 45.7 80 Control Catalog 0.8 1.5 1.2 2.1 1.7 3.1 2.6 4.5 3.1 5.6 4.0 7.0 4.7 8.4 6.0 10.5 8.0 14 10 17.5 12 21 14 24.5 16 28 20 35 26 45 32 56 40 70 64 112 600V 1 1.9 1.5 2.6 2.2 3.8 3.2 5.6 3.9 6.8 4.8 8.5 6 10.5 7.1 12.5 10 16 11.4 20 14.2 25 15.6 27.5 17.1 30 24.2 42.5 31.4 55 42.8 75 48.5 85 80 140 5-75 IEC Power Devices Section 5 IEC Contactors & Starters Type 2 Coordination C-2000 C-2000 Contactors Product Type C-2000 contactors and starters have been tested and certified to meet IEC 947.4 Type 2 coordination when protected with the type “J” fuses shown in tables. “Type 2 coordination requires that, under short-circuit conditions, the contactor or starter shall cause no danger to persons or installation and shall be suitable for further use. The risk of contact welding is recognized, in which case the manufacturer shall indicate the measures to be taken as regards the maintenance of the equipment.” (IEC 947.4) Short Circuit Test Condition...................100,000 Amps (maximum) Fuse Type ............................................................................................................J Fuse Manufacturer Product Number or Type Bussmann................................................................................................LPJ-SP Gould Shawmut ..........................................................................................AJT Maximum Amps Type LPJ-SP or AJT Maximum Fuse 10 13.8 17.5 22 25 32 34 42 48 62 68 80 104 156 192 302 398 480 602 25 35 40 45 60 60 70 90 100 125 125 150 200 300 400 450 800 900 1000 Maximum Amps Type LPJ-SP or AJT Maximum Fuse 0.65 - 1.1 1 - 1.5 1.3 - 1.9 1.8 - 2.7 2.5 - 4.1 4 - 6.3 5.5 - 8.5 8 - 12 10 - 16 14.5 - 18 17.5 - 22 21 - 26 25 - 35 30 - 40 11.5 - 15 14.5 - 19 18.5 - 25 24 - 32 30 - 43 42 - 45 54 - 65 64 - 82 78 - 97 90 - 110 55 - 80 63 - 90 90 - 120 110 - 140 140 - 180 120 - 190 120 - 190 175 - 280 175 - 280 200 - 310 200 - 310 120 - 190 120 - 190 175 - 280 175 - 280 250 - 400 250 - 400 315 - 500 315 - 500 430 - 650 430 - 650 1.5 2 4 4 8 10 12 20 25 35 45 45 60 70 30 35 45 60 70 100 125 150 200 200 125 150 200 250 300 350 350 450 450 450 450 400 400 600 600 800 800 900 900 1000 1000 CL00 CL01 CL02 CL25 CL03 CL04 CL45 CL05 CL06 CL07 CL08 CL09 CL10 CK08 CK09 CK95 CK10 CK11 CL12 C-2000 Starters Note: Use of short circuit protective device not in compliance with the above manufacturer’s type may invalidate the coordination. Overload Type Type 2 - Maintenance Procedure, C-2000 Products Before working on contactor/starter, make sure all electrical power is turned off, including the control voltage. Step 1. Tighten down all terminals, on the CL00 thru CL45, (including 4th pole auxiliary contacts), securing them in place. Step 2. Remove outer cover, with screwdriver: CL Products: The cover has a snap fit design. Pry the ends of the cover loose from the contactor with screwdriver, releasing the snaps. CK Products: The cover is held with two screws. Loosen the screws and remove. Step 3. Remove inner cover, CL03 thru CL10 only, which is held by 2 or 4 screws. Loosen screws and remove. Step 4. Examine contacts for welding. If a contact is welded, gently pry the contacts apart using a screwdriver. Step 5. Reassemble by reversing the above procedure (Steps 4, 3, 2). To ensure contactor is operating correctly, operate at least ten times with main power off. Confirm that all poles are correctly opening and closing with a continuity meter. RT1F RT1G RT1H RT1J RT1K RT1L RT1M RT1N RT1P RT1S RT1T RT1U RT1V RT1W RT2A RT2B RT2C RT2D RT2E RT2G RT2H RT2J RT2L RT2M RT3PB RT3PC RT3PD RT3PE RT3PF RT4LN RT4N RT4LP RT4P RT4LR RT4R RT5A RT5LA RT5B RT5LB RT5C RT5LC RT5D RT5LD RT5E RT5LE Type 2 Coordination, Group Installation, CR72 Manual Motor Controllers Available Fault Current 42KA Voltage Motor Control Product Number C-2000 Contactor Size J 480 CR72AMA-MP CL00-04 100 Fuse Class Maximum Amps RRK-5 30 CC 30 Note: See GEP-1260 for more information on CR72 group installations 5-76 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors & Starters Wiring Diagrams C-2000 Typical Schematic Diagram For C-2000 Three-Phase AC Motor Starters/Contactors Showing Start-Stop Push Button Connections Typical Schematic Diagram For C-2000 Single-Phase AC Motor Starters/ Contactors Showing Start-Stop Push Button Connections Start-Start Push Button/Control Transformer Elementary Notes: Holding interlock is numbered 13 and 14 on some forms and the normally closed auxiliary contact is not standard on all forms. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-77 IEC Power Devices Section 5 IEC Contactors & Starters Wiring Diagrams C-2000 Legend F and R FLS RLS OL Forward and Reverse Line Contactors, Mechanically and Electronically Interlocked Forward Limit Switch Reverse Limit Switch Thermal Overload Relay Notes: Cross Electrical interlocks may be marked 01 and 02. Wires “B” and “C” are omitted. These wires must be added if limit switches are not used. l Factory wired terminals m Field wired terminals Typical Schematic Drawing for C-2000 Three-Phase AC Reversing Motor Starter/ Contactors Showing Momentary Contact Push Button Station Connections Momentary Contact Push Button Station/Control Transformer Elementary Product Number Selection Instructions: See page 5-37 5-78 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View CL00A310T, CL01A310T, CL02A310T and RL4 Relays CL25A310T* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-79 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View CL04A310M* CL45A310M* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Product Number Selection Instructions: See page 5-37 5-80 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View CL06A311M*, CL07A311M*, CL08A311M* CL09A311M*, CL10A311M* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-81 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Reversing Contactor Front View and AC Contactor Side View LAR00A*, LAR01A*, LAR02A* LAR25* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Product Number Selection Instructions: See page 5-37 5-82 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and DC Contactor Side View LAR04A* LAR45A* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-83 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and DC Contactor Side View LAR06A*, LAR07A*, LAR08A* LAR09A*, LAR10A* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Product Number Selection Instructions: See page 5-37 5-84 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and DC Contactor Side View CL00D310T*, CL01D310T*, CL02D310T* CL25D310T* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-85 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and DC Contactor Side View CL04D310M* CL45D310M* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Product Number Selection Instructions: See page 5-37 5-86 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Reversing Contactor Front View and DC Contactor Side View LDR00A*, LDR01A*, LDR02A* LDR25A* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-87 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Reversing Contactor Front View and DC Contactor Side View LDR04A* LDR45A* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Product Number Selection Instructions: See page 5-37 5-88 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC/DC Contactor Side View CL06E311M† CL07E311M†, CL08E311M† CL09E311M†, CL010E311M† Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-89 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Reversing Contactor Front View and AC/DC Contactor Side View LER06A†, LER07A†, LER08A† LER09A†, LER010A† Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) B Extra Auxiliary Contacts, Front Mounted (if used) C Pneumatic Timer (if used) D Mechanical Latch (if used) E Transient Voltage Suppressor Add 1/2 inch for electrical clearance to enclosure. Product Number Selection Instructions: See page 5-37 5-90 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View CK75CE311*, CK08CE311* CK09BE311*, CK95BE311* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) (1 Standard) B Electronic Actuator Modulator Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-91 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View CK10CE311*, CK10BE311*, CK11CE311*, CK11BE311* CK12BE311* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) (1 Standard) B Electronic Actuator Modulator Product Number Selection Instructions: See page 5-37 5-92 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View KAR75C*, KAR08C* KAR09B*, KAR95B* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) (1 Standard) B Electronic Actuator Modulator Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-93 IEC Power Devices Section 5 IEC Contactors Dimensions C-2000 in. Outlines and Dimensions (mm) For Estimating Only Contactor Front View and AC Contactor Side View KAR10C*, KAR10B*, KAR11C*, KAR11B* KAR12B* Legend and Notes A Extra Auxiliary Contacts, Side Mounted (if used) (1 Standard) B Electronic Actuator Modulator Product Number Selection Instructions: See page 5-37 5-94 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Selection Guide C-2000 Nonreversing Starters - AC Using contactor with CL prefix Using contactor with CK prefix ➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑ ➒ ➓ 11 Family Name Starter Size Contactor Family Version Coil Selection Overload Selection Overload Amp Range Auxiliary Contacts Enclosure Operator Lights CPT Reversing Starters - AC Using contactor with CL prefix Using contactor with CK prefix ➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑ ➒ ➓ 11 Family Name Starter Size Contactor Family Version Coil Selection Overload Selection Overload Amp Range Auxiliary Contacts Enclosure Operator Lights CPT Starter Size Contactor Family Version Coil Selection Overload Selection Overload Amp Range Auxiliary Contacts Enclosure Operator Lights CPT Nonreversing Starters - Wye-delta Using contactor with CL prefix LAD Using contactor with CK prefix KAD 11 Family Name Reversing/Nonreversing Starters - DC controlled Reversing using contactor with CL prefix LDR Nonreversing using contactor with CL prefix LDC ∂ Family Name Digits 11 Family Name Contactor Family Version Starter Size Description Auxiliary Contacts Overload Amp Range Digits CL A Contactor with CL prefix KAC Assembled nonreversing starters CK B Contactor with CK prefix LAR Assembled reversing starters CL C Contactor with CK prefix KAR Assembled reversing starters CK LAD Assembled wye-delta starters CL Assembled wye-delta starters CK LDC Assembled nonreversing starters (DC controlled) CL Assembled reversing starters (DC controlled) Contactor No. Lights Number or Digit For Contactor with CK prefix For Contactor with CL Prefix 60 Hz 50 Hz 60/50 Hz or DC 1 D Single-Phase 115 V 230 V Three-Phase 200 V 230 V 460 V 575 V KW 50 Hz F 380415 V L J N 00 10 0.5 1.5 3 3 5 7.5 4 01 13.8 0.75 2 3 3 7.5 10 5.5 S 02 17.5 1 3 5 5 10 15 7.5 U 25 22 1.5 3 5 7.5 15 15 11 W 04 32 2 5 10 10 20 25 16 Y 45 34 3 5 10 10 25 25 18.5 06 48 3 7.5 15 15 30 40 22 07 62 5 10 20 20 40 50 30 08 68 5 15 20 25 50 60 37 09 80 7.5 15 25 30 60 75 45 10 96 10 20 30 40 75 75 55 Digit Class 75 140 10 25 40 50 100 125 75 W Class 10 08 156 15 30 50 60 125 125 90 F1 Class 30 09 192 60 75 150 150 132 95 302 100 100 250 300 160 10 398 125 150 300 400 220 11 480 150 200 400 500 280 12 602 200 250 500 600 375 Rev. 7/13 Prices and data subject to change without notice CPT Õ Coil Selection CL Horsepower (60 Hz) Max. Amps @460 V Operator Description Assembled nonreversing starters KAD Enclosure à Contactor Family Version Contactor Prefix À Starter Size CK Overload Selection LAC LDR CL Coil Selection www.geindustrial.com Œ Overload Selection Overload Type/Class Manual/Automatic 1 Class 30 overloads available with CK09-CK12 contactors only. Control Catalog 5-95 IEC Power Devices Section 5 IEC Assembled Starters Selection Guide C-2000 œ Overload Amp Range ” Lights For Starters Amp Range Digit Class 10 Class 10 Class 10 Class 10 and Class 30 CL00-CL45 CL05-CL10 CK75-08 CK09-95 A 11.5-15 Class 10 and Class 30 CK10-12 B RIL X-Coil 120-190 C RIL NO Aux. Digits A Description None B 0.16-0.26 14.5-19 55-80 175-280 D RIL X-Coil, GIL NC Aux. C 0.25-.41 18.5-25 63-90 250-400 E RIL NO Aux., GIL NC Aux. D 0.4-.65 24-32 90-120 315-500 F GIL NC Aux. 30-43 110-140 430-650 G GIL X-Coil E F .65-1.1 G 1-1.5 42-55 140-190 H 1.3-1.9 54-65 Digits J 1.8-2.7 64-82 B RIL/Forward, WIL/Rev. X-Coil K 2.5-4.1 C RIL/Forward, WIL/Rev. X NO L 4-6.3 60-90 (Class 30 only) D RIL/Forward, WIL/Rev. X-Coil, GIL NC Aux. (2 in series) E RIL/Forward, WIL/Rev. X-NO, GIL NC Aux. (2 in series) 80-125 (Class 30 only) F GIL NC Aux. (2 in series) 78-97 90-110 For Reversers Only M 5.5-8.5 N 8-12 120-190 P 10-16 175-280 R For Wye-Delta Only Digits 200-310 S 14.5-18 T 17.5-22 U 21-26 V 25-32 W 30-40 Description Description B RIL X-Coil D RIL X-Coil, GIL NC Aux. H Red/Run, Y/Start X-Coil J Red/Run, Y/Start X-Coil, GIL NC Aux. For wye-delta starters, overload current rating is determined by multiplying motor amps x .58. – Auxiliary Contacts Digits A 1NO-1NC C 2NO-0NC Digits or Number CPT Digits None B — Enclosure 11 Description Description B Control Circuit Fusing C Wired For Separate Control D Separate Control and CCF F Standard CPT, 110-120 V Sec (One Sec Fuse, Two Primary Fuses) H CPT + ExtraVA, 110-120 V Sec (One Sec Fuse, Two Primary Fuses) Description 1 NEMA 1 w/Reset 2 NEMA 12/3R w/Reset 4 NEMA 4 w/Reset 5 NEMA 1, no Reset 6 NEMA 12/3R, no Reset 8 NEMA 4, no Reset “ Operator Digits A 5-96 Description None B Start/Stop Push Button C H-O-A Selector Switch D On/Off Selector Switch E Forward/Off/Reverse Selector Switch F Forward/Reverse Selector Switch with Start/Stop Push Button G Forward/Stop/Reverse Push Buttons Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Nonreversing AC C-2000 Step-By-Step Selection and Pricing This step-by-step process will allow you to select and price your assembled starter. In each step, find the options—contactor, coil, overload relay, etc.—you need. Transfer the product number digits and price components to the corresponding boxes at the bottom of page 5-100. When you have finished the appropriate number of steps for your starter, you will have built a complete product number and established the prices that add up to a total list price, GO-10CA. Not all starters require completion of all steps; note minimum and optional steps required for various starters in the product number and price line form. (Photocopying this form will allow for its repeated use.) ∂ Select Contactor Select contactor and enclosure. Transfer the product number digits to the boxes marked ∂ in the product number line and the price to the box marked ∂ in the price line. Horsepower (60 Hertz) Single-Phase Contactor Max. FLA 115 V 230 V List Price, GO-10CA NEMA Enclosure (For dimensions, see pp. 5-109, 5-110.) Three-Phase 200 V 230 V 460 V 575 V Product No. Digits Type 1 (GeneralPurpose) Open Type 12/3R (Dust- and Rain- Tight) Type 4 (Water-Tight) CL00 10 $94.00 $119.00 $159.00 $267.00 CL01 13.8 $117.00 $142.00 $182.00 $290.00 CL02 17.5 $132.00 $157.00 $197.00 $305.00 CL25 22 $144.00 $169.00 $211.00 $319.00 CL04 32 $167.00 $199.00 $239.00 $347.00 CL45 34 $183.00 $215.00 $286.00 $394.00 CL06 48 $212.00 $257.00 $377.00 $537.00 CL07 62 $252.00 $297.00 $417.00 $577.00 CL08 68 $307.00 $352.00 $472.00 $632.00 CL09 80 $347.00 $425.00 $518.00 $718.00 CL10 96 $489.00 $567.00 $660.00 $860.00 CK75 140 $875.00 $1,096.00 $1,296.00 $1,896.00 CK08 156 $1,105.00 $1,316.00 $1,516.00 $2,116.00 CK09 192 $1,495.00 $1,706.00 $1,906.00 $2,506.00 CK95 302 $2,070.00 $2,281.00 $2,381.00 $2,981.00 CK10 398 $2,870.00 $3,585.00 $3,820.00 $4,420.00 CK11 480 $4,370.00 $5,085.00 $5,320.00 $5,920.00 CK12 602 $5,870.00 $6,585.00 $6,820.00 $7,420.00 1 KAC10C and KAC11C are for use with maximum fuse 1000A, and maximum breaker 600A. For higher ratings, substitute “C” version with “B” version in product digit six. Add $270.00 to List Price for KAC10B and $420.00 to List Price for KAC11B. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-97 IEC Power Devices Section 5 IEC Assembled Starters Nonreversing AC C-2000 Step-By-Step Selection and Pricing À Select Coil Voltage à Select Overload Type Select coil based on control circuit voltage or, if you plan to add a control power transformer (step “), on primary circuit voltage instead. Transfer the product number digit to the boxes marked À in the product number line. Note that there is no price component to this step. Select overload type. Transfer the product number digit to the box marked à in the product number line. Note that there is no price component to this step. Coil (control circuit voltage) beginning with LAC 60 Hz 50 Hz 24 24 60/50 Hz (AC/DC) 24-28 D F Primary Volts For Prod. Nos. beginning with LAC Z Z W W For Prod. Nos. beginning with KAC Class 30 — F 1 42 42-48 110 110-127 J 208 L 208 220-240 220/230 220-250 N 380/400 380-415 U 415 — W 500 440-500 Y 240 600 Manual/ Automatic Reset For Product Nos. beginning KAC Class 10 None Product Number Digit Prod. No. Digit 48 480 Overload Type Primary Circuit Voltage (for CPT) beginning with KAC 120 277 Product Number Digit For Product Nos. beginning LAC S 480 600 Õ Select Overload Rating From among the columns that correspond both to your product number from step ∂ and to the overload class (10 or 30) from step Ã, select the specific amp range (be sure to observe the maximum FLA rating for your starter as indicated in step ∂). Transfer the product number digit to the box marked Õ in the product number line and the price to the box marked Õ in the price line. Class 10 For Product Nos. beginning LAC00-LAC45 Overload Amp Range List Price Adder, GO-10CA For Product Nos. beginning LAC06-LAC10 Overload Amp Range List Price Adder, GO-10CA Class 30 For Product Nos. beginning KAC75-KAC08 Overload Amp Range List Price Adder, GO-10CA For Product Nos. beginning KAC09-KAC95 Overload Amp Range List Price Adder, GO-10CA For Product Nos. beginning KAC10-KAC12 Overload Amp Rang e List Price Adder, GO-10CA For Product Nos. beginning KAC09-KAC95 Overload Amp Range List Price Adder, GO-10CA For Product Nos. beginning KAC10-KAC12 Overload Amp Range List Price Adder, GO-10CA Product No. Digi t — — 11.5-15 $98.00 — — — — 120-190 $641.00 — — 120-190 $641.00 A 0.16-.26 $55.00 14.5-19 $98.00 55-80 $185.00 — — 175-280 $641.00 — — 175-280 $641.00 B 0.25-.41 $55.00 18.5-25 $98.00 63-90 $185.00 — — 250-400 $641.00 — — 250-400 $641.00 C — 315-500 $903.00 — — 315-500 $903.00 D E 0.4-.65 $55.00 24-32 $98.00 90-120 $185.00 — — — 30-43 $98.00 110-140 $225.00 — — 430-650 $903.00 — — 430-650 $903.00 .65-1.1 $55.00 — — 140-190 $225.00 — — — — — — — — F 1-1.5 $55.00 42-55 $98.00 — — — — — — — — — — G 1.3-1.9 $55.00 54-65 $98.00 — — — — — — — — — — H 1.8-2.7 $55.00 64-82 $117.00 — — — — — — — — — — J 2.5-4.1 $55.00 — — — — — — — — 45-70 $285.00 — — K 4-6.3 $55.00 78-97 $143.00 — — — — — — 60-90 $285.00 — — L 5.5-8.5 $57.00 90-110 $143.00 — — — — — — 80-125 $285.00 — — M 8-12 $57.00 — — — — 120-190 $285.00 — — 120-190 $285.00 — — N 10-16 $57.00 — — — — 175-280 $285.00 — — 175-280 $285.00 — — P — — — — — — 200-310 $380.00 — — 200-310 $380.00 — — R 14.5-18 $57.00 — — — — — — — — — — — — S 17.5-22 $57.00 — — — — — — — — — — — — T 21-26 $57.00 — — — — — — — — — — — — U 25-32 $65.00 — — — — — — — — — — — — V 30-40 $78.00 — — — — — — — — — — — — W None 0 None 0 None 0 — — None 0 None 0 None 0 Z 5-98 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Nonreversing AC C-2000 Step-By-Step Selection and Pricing Œ Select Auxiliary Contacts – Select Operator Select additional auxiliary contacts. Transfer the product number digit to the box marked Œ in the product number line and the price to the box marked Œ in the price line. A holding interlock is standard. Select operator. Transfer the product number digit to the box marked – in the product number line and the price to the box marked – in the price line. Be sure your selection agrees with your contactor selection in step ∂. Contacts Product Number Digit List Price Adder, GO-10CA None A $0.00 1NO-1NC B $21.00 2NO C $21.00 This is the last step in selection of open starters. For Prod. Nos. beginning LAC in Type 1 enclosures Operator Prod. No. Digit List Price Adder, GO-10CA For Prod. Nos. beginning LAC in Type 12/3R or Type 4 enclosures or KAC in any enclosure Prod. No. Digit List Price Adder, GO-10CA None A $0.00 A $0.00 START/STOP push button B $40.00 B $110.00 HOA selector switch C $40.00 C $110.00 ON-OFF selector switch D $40.00 D $110.00 œ Select Enclosure — Select Indicating Light Select enclosure. Transfer the product number digit to the box marked œ in the product number line and the price to the box marked œ in the price line. Note that your enclosure selection here MUST agree with that made in step ∂. Note, too, that the price component for this step is $0.00 for units with reset and an $8.00 subtraction for units without reset. Select indicating light. Transfer the product number digit to the box marked — in the product number line and the price to the box marked — in the price line. Be sure your selection agrees with your contactor selection in step ∂. For Prod. Nos. beginning LAC in Type 1 enclosures Product No. Digit NEMA Type NEMA Types 12/3R NEMA Type 4 List Price Subtraction, GO-10CA Indicating Light Prod. No. Digit For Prod. Nos. beginning LAC in Type 12/3R or Type 4 enclosures or KAC in any enclosure List Price Adder, GO-10CA Prod. No. Digit List Price Adder, GO-10CA With reset 1 2 4 $0.00 None A $0.00 A $0.00 Without reset 5 6 8 (8.00) Red RUN across coil B $40.00 B $75.00 Red RUN across NO auxiliary contact C $40.00 C $97.00 Red RUN across coil & green STOP across NC auxiliary contact D $150.00 Red RUN across NO auxiliary contact & green STOP across NC auxiliary contact E $172.00 This is the last step required for selection of enclosed starters. If desired, select operators, indicating lights and CPTs in steps – to “. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Green STOP across NC auxiliary contact F $75.00 Green RUN across coil G $75.00 Control Catalog 5-99 IEC Power Devices Section 5 IEC Assembled Starters Nonreversing AC C-2000 Step-By-Step Selection and Pricing “ Select Control Power Transformer Select control power transformer. Transfer the product number digit to the box marked “ in the product number line and the price to the box marked “ in the price line. Be sure your selection agrees with your contactor selection in step ∂. CPT VA For Product Numbers beginning with LAC For Product Numbers beginning with KAC Standard 50 250 Extra VA 150 300 For Prod. Nos. beginning LAC Prod. No. . Digit Control Power Transformer For Prod. Nos. beginning KAC List Price Adder, GO-10CA Prod. No. List Price Adder, Digit GO-10CA $0.00 None $0.00 Fused control circuit (without control transformer)—one fuse B $110.00 B Separate control circuit C $0.00 C $0.00 Fused separate control circuit (one fuse) D $110.00 D $110.00 Control transformer, standard capacity, 110-120 V 50/60 Hz secondary voltage, one secondary fuse, two primary fuses F $300.00 F $450.00 Control transformer, extra capacity, 110-120 V 50/60 Hz secondary voltage, one secondary fuse, two primary fuses H $390.00 H $590.00 $110.00 -------------------------------------------Minimum steps for enclosed starter-------------------------------------------------------------------------------------Maximum steps for open starter----------------------------------------------------------------------------------------Minimum steps for open starter------------------------------------- Product r Optional steps for enclosed --------------starter------------- = Complete Prod. No. Price $ +0 +0 – = $ Total List Price, GO-10CA Note: Product Number should not end in a “None” option. For example, KAC08CJZZA should be KAC08CJ. Control Circuit Fusing Per the NEC and UL508 Section 18.2 - Control Circuit Fuses must be used when the branch circuit protective device rating is too large to serve as protection for the control circuit. This depends on the control wire size and whether all control circuit wires are within the enclosure. See table below: The factory must provide this protection, if the circuit provided by the factory requires the fuses. The factory will provide control circuit fuses in enclosed starters and contactors with pilot devices, control relays or other control components that are factory wired; when used with line voltage control; when the size listed below is being supplied. Provide supplemental control circuit protection if control circuits with wires longer than 12 inches are connected to branch circuit protection exceeding the ratings below Non-combination starters (LAC, LAR, LAD, KAC, KAR, KAD) Supplied with: —CL10 Contactors and Larger —Overload Relays 90 amps and larger Control Circuit fuses must be added to the enclosed starter or contactor pricing. Control Circuit Wire Size (AWG) 22 20 18 16 14 12 5-100 Maximum Branch Circuit Protection Rating (Amperes) Conductors Conductors within Enclosure outside Enclosure 12 20 25 40 100 120 3 5 7 10 45 60 Control Catalog Maximum Supplemental Control Circuit Protection Rating (Amperes) 3 5 7 10 20 25 All CPTs in enclosed control will be supplied with primary fuses. CPTs without primary fuses are no longer available. When control circuit fuses are not factory supplied, customer provided wiring or branch circuit protection sizing to these contactors and starters may still require that the customer/installer add the fusing in the field. It will be the customer/installer’s responsibility to ensure code compliance under these conditions. www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Reversing AC C-2000 Step-By-Step Selection and Pricing This step-by-step process will allow you to select and price your assembled starter. In each step, find the options—contactor, coil, overload relay, etc.—you need. Transfer the product number digits and price components to the corresponding boxes at the bottom of page 5-104. When you have finished the appropriate number of steps for your starter, you will have built a complete product number and established the prices that add up to a total list price, GO-10CA. Not all starters require completion of all steps; note minimum and optional steps required for various starters in the product number and price line form. (Photocopying this form will allow for its repeated use.) ∂ Select Contactor Select contactor and enclosure. Transfer the product number digits to the boxes marked ∂ in the product number line and the price to the box marked ∂ in the price line. Horsepower (60 Hertz) List Price, GO-10CA NEMA Enclosure (For dimensions, see pp. 5-109, 5-110.) Contactor Max. FLA 115 V 230 V 200 V 230 V 460 V 575 V Product No. Digits Open Type 1 (GeneralPurpose) Type 12/3R (Dust- and Rain-Tight) Type 4 (Water-Tight) CL00 10 $257.00 $291.00 $361.00 $472.00 CL01 13.8 $303.00 $337.00 $407.00 $518.00 CL02 17.5 $333.00 $367.00 $437.00 $548.00 CL25 22 $361.00 $395.00 $465.00 $576.00 CL04 32 $431.00 $465.00 $535.00 $644.00 CL45 34 $463.00 $497.00 $567.00 $676.00 CL06 48 $559.00 $618.00 $708.00 $995.00 CL07 62 $639.00 $698.00 $788.00 $1075.00 CL08 68 $749.00 $808.00 $898.00 $1185.00 CL09 80 $879.00 $968.00 $1068.00 $1453.00 CL10 96 $1163.00 $1252.00 $1352.00 $1737.00 CK75 140 $2035.00 $2385.00 $2885.00 $3910.00 CK08 156 $2475.00 $3025.00 $3325.00 $4350.00 CK09 192 $3275.00 $3825.00 $4165.00 $5140.00 CK95 302 $4435.00 $4985.00 $5185.00 $6200.00 CK10 398 $6535.00 $7085.00 $7785.00 $8971.00 CK11 480 $9535.00 $10285.00 $10785.00 $11971.00 CK12 602 $12835.00 $13585.00 $14285.00 $15271.00 1 KAR10C and KAR11C are for use with max. fuse 1000A, and max. breaker 600A. For higher ratings, substitute “C” version with “B” version in product digit six. Add $540.00 to List Price for KAR10B and $840.00 to List Price for KAR11B version. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-101 IEC Power Devices Section 5 IEC Assembled Starters Reversing AC C-2000 Step-By-Step Selection and Pricing À Select Coil Voltage à Select Overload Type Select coil based on control circuit voltage or, if you plan to add a control power transformer (step “), on primary circuit voltage instead. Transfer the product number digit to the boxes marked À in the product number line. Note that there is no price component to this step. Select overload type. Transfer the product number digit to the box marked à in the product number line. Note that there is no price component to this step. Coil (control circuit voltage) For Product Nos. beginning with LAR 60 Hz 50 Hz 24 24 For Product Nos. beginning with KAR 60/50 Hz (AC/DC) 24-28 D F Manual/ Automatic Reset Class 10 Class 30 For Prod. Nos. beginning with KAR 1 42 42-48 110 110-127 208 J L 208 220-240 220/230 220-250 N 380/400 380-415 U 240 S 415 600 Primary Volts For Prod. Nos. beginning with LAR For Product Numbers beginning with KAR None Product No. Digit Prod. No. Digit 48 480 Overload Type Primary Circuit Voltage (for CPT) 120 277 Product No. Digit For Product Numbers beginning with LAR 480 W 500 440-500 Y 600 Õ Select Overload Rating From among the columns that correspond both to your product number from step and to the overload class (10 or 30) from step Ã, select the specific amp range (be sure to observe the maximum FLA rating for your starter as indicated in step ∂). Transfer the product number digit to the box marked Õ in the product number line and the price to the box marked Õ in the price line. Class 10 Product No. Digit beginning LAR00-LAR45 Overload Amp Range List Price Adder, GO-10CA Product No. Digit beginning LAR06-LAR10 Overload Amp Range List Price Adder, GO-10CA Class 30 Product No. Digit beginning KAR75-KAR08 Overload Amp Range Product No. Digit beginning KAR09-KAR95 Product No. Digit beginning KAR10-KAR12 Product No. Digit beginning KAR09-KAR95 Product No. Digit beginning KAR10-KAR12 List Price Adder, GO-10CA Overload Amp Range Overload Amp Range Overload Amp Range List Price Adder, GO-10CA Overload Amp Range List Price Adder, GO-10CA List Price Adder, GO-10CA List Price Adder, GO-10CA Prod. No. Digit — — 11.5-15 $98.00 — — — — 120-190 $641.00 — — 120-190 $641.00 A 0.16-.26 $55.00 14.5-19 $98.00 55-80 $185.00 — — 175-280 $641.00 — — 175-280 $641.00 B 0.25-.41 $55.00 18.5-25 $98.00 63-90 $185.00 — — 250-400 $641.00 — — 250-400 $641.00 C 0.4-.65 $55.00 24-32 $98.00 90-120 $185.00 — — 315-500 $903.00 — — 315-500 $903.00 D E — — 30-43 $98.00 110-140 $225.00 — — 430-650 $903.00 — — 430-650 $903.00 .65-1.1 $55.00 — — 140-190 $225.00 — — — — — — — — F 1-1.5 $55.00 42-55 $98.00 — — — — — — — — — — G 1.3-1.9 $55.00 54-65 $98.00 — — — — — — — — — — H 1.8-2.7 $55.00 64-82 $117.00 — — — — — — — — — — J 2.5-4.1 $55.00 — — — — — — — — 45-70 $285.00 — — K 4-6.3 $55.00 78-97 $143.00 — — — — — — 60-90 $285.00 — — L 5.5-8.5 $57.00 90-110 $143.00 — — — — — — 80-125 $285.00 — — M N 8-12 $57.00 — — — — 120-190 $285.00 — — 120-190 $285.00 — — 10-16 $57.00 — — — — 175-280 $285.00 — — 175-280 $285.00 — — P — — — — — — 200-310 $380.00 — — 200-310 $380.00 — — R S 14.5-18 $57.00 — — — — — — — — — — — — 17.5-22 $57.00 — — — — — — — — — — — — T 21-26 $57.00 — — — — — — — — — — — — U 25-32 $65.00 — — — — — — — — — — — — V 30-40 $78.00 — — — — — — — — — — — — W None 0 None 0 None 0 — — None 0 None 0 None 0 Z 5-102 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Reversing AC C-2000 Step-By-Step Selection and Pricing Œ Select Auxiliary Contacts – Select Operator Select additional auxiliary contacts. Transfer the product number digit to the box marked Œ in the product number line and the price to the box marked Œ in the price line. A holding interlock is standard. Select operator. Transfer the product number digit to the box marked – in the product number line and the price to the box marked – in the price line. List Price Adder, GO-10CA Contacts Product No. Digit None A $0.00 1NO-1NC B $42.00 2NO C $42.00 Operator Product No. Digit List Price Adder, GO-10CA None A $0.00 FWD OFF REV selector switch E $110.00 FORWARD-REVERSE selector switch with START/STOP push button F $235.00 FWD STOP REV push buttons G $125.00 This is the last step of open starters. œ Select Enclosure — Select Indicating Light Select enclosure. Transfer the product number digit to the box marked œ in the product number line and the price to the box marked œ in the price line. Note that your enclosure selection here MUST agree with that made in step ∂. Note, too, that the price component for this step is $0.00 for units with reset and an $8.00 subtraction for units without reset. Select indicating light. Transfer the product number digit to the box marked — in the product number line and the price to the box marked — in the price line. Be sure your selection agrees with your contactor selection in step ∂ . Product No. Digit NEMA Type With reset Without reset 1 5 NEMA Types 12/3R NEMA Type 4 List Price Subtraction, GO-10CA 2 4 $0.00 6 8 (8.00) This is the last step required for selection of enclosed starters. If desired, select operators, indicating lights and CPTs in steps – to “. Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Indicating Light Product No. Digit List Price Adder, GO-10CA None A $0.00 Red FORWARD, white REVERSE indicating lights across coil B $150.00 Red FORWARD, white REVERSE indicating lights across NO auxiliary contact C $194.00 Red FORWARD, white REVERSE across coil green STOP across NC auxiliary contact (2 in series) D $225.00 Red FORWARD, white REVERSE, green STOP across NC auxiliary contact (2 in series) E $269.00 Green STOP across NC auxiliary contact (2 in series) F $ 75.00 Control Catalog 5-103 IEC Power Devices Section 5 IEC Assembled Starters Reversing AC C-2000 Step-By-Step Selection and Pricing “ Select Control Power Transformer Select control power transformer. Transfer the product number digit to the box marked “ in the product number line and the price to the box marked “ in the price line. Be sure your selection agrees with your contactor selection in step ∂. CPT VA For Product Numbers beginning with LAR For Product Numbers beginning with KAR Standard 50 250 Extra VA 150 300 For Prod. Nos. beginning LAR Prod. No. Digit Control Power Transformer List Price Adder, GO-10CA For Prod. Nos. beginning KAR Prod. No. Digit List Price Adder, GO-10CA None — $0.00 — $0.00 Fused control circuit (without control transformer)—one fuse B $110.00 B $110.00 Separate control circuit C $0.00 C $0.00 Fused separate control circuit (one fuse) D $110.00 D $110.00 Control transformer, standard capacity, 110-120 V 50/60 Hz secondary voltage, one secondary fuse, two primary fuses F $300.00 F $450.00 Control transformer, extra capacity, 110-120 V 50/60 Hz secondary voltage, one secondary fuse, two primary fuses H $390.00 H $590.00 ---------------------------------------Minimum steps for enclosed starter----------------------------------------------Optional steps for enclosed -------------starter---------- ----------------------------------Maximum steps for open starter----------------------------------------------------------------------Minimum steps for open starter------------------------------------- Product = Complete Prod. No. Price $ +0 +0 + + - Note: Product Number should not end in a "None" option. For example, KAR08CJZZA should be KAR08CJ. + + + = $ Total List Price, GO-10CA Control Circuit Fusing Per the NEC and UL508 Section 18.2 - Control Circuit Fuses must be used when the branch circuit protective device rating is too large to serve as protection for the control circuit. This depends on the control wire size and whether all control circuit wires are within the enclosure. See table below: The factory must provide this protection, if the circuit provided by the factory requires the fuses. The factory will provide control circuit fuses in enclosed starters and contactors with pilot devices, control relays or other control components that are factory wired; when used with line voltage control; when the size listed below is being supplied. Provide supplemental control circuit protection if control circuits with wires longer than 12 inches are connected to branch circuit protection exceeding the ratings below Non-combination starters (LAC, LAR, LAD, KAC, KAR, KAD) Supplied with: —CL10 Contactors and Larger —Overload Relays 90 amps and larger Control Circuit fuses must be added to the enclosed starter or contactor pricing. Control Circuit Wire Size (AWG) 22 20 18 16 14 12 5-104 Maximum Branch Circuit Protection Rating (Amperes) Conductors Conductors within Enclosure outside Enclosure 12 20 25 40 100 120 3 5 7 10 45 60 Control Catalog Maximum Supplemental Control Circuit Protection Rating (Amperes) 3 5 7 10 20 25 All CPTs in enclosed control will be supplied with primary fuses. CPTs without primary fuses are no longer available. When control circuit fuses are not factory supplied, customer provided wiring or branch circuit protection sizing to these contactors and starters may still require that the customer/installer add the fusing in the field. It will be the customer/installer’s responsibility to ensure code compliance under these conditions. www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Wye-Delta Open Transition AC C-2000 Step-By-Step Selection and Pricing This step-by-step process will allow you to select and price your assembled starter. In each step, find the options—contactor, coil, overload relay, etc.—you need. Transfer the product number digits and price components to the corresponding boxes at the bottom of page 5-108. When you have finished the appropriate number of steps for your starter, you will have built a complete product number and established the prices that add up to a total list price, GO-10CA. Not all starters require completion of all steps; note minimum and optional steps required for various starters in the product number and price line form. (Photocopying this form will allow for its repeated use.) ∂ Select Contactor Select contactor and enclosure. Transfer the product number digits to the boxes marked ∂ in the product number line and the price to the box marked ∂ in the price line. Horsepower (60 Hertz) List Price, GO-10CA NEMA Enclosure (For dimensions, see pp. 5-109, 5-110.) Three-phase M1 & M2 Line & Delta Contactor S1 Wye Contactor Max Motor FLA 200 V 230 V 460 V 575 V Prod. No. Digits Open Type 1 (GeneralPurpose) Types 12/3R (Dust- and Rain- Tight) Type 4 (Water-Tight) $1431.00 CL02 CL01 30 — — 20 20 LAD02A $855.00 $1035.00 $1106.00 CL25 CL01 38 — — 25 25 LAD25A $889.00 $1069.00 $1140.00 $1465.00 CL04 CL04 55 15 20 40 50 LAD04A $978.00 $1158.00 $1229.00 $1554.00 CL06 CL04 83 25 30 60 75 LAD06A $1104.00 $1412.00 $1532.00 $2138.00 CL07 CL06 107 30 40 75 100 LAD07A $1227.00 $1535.00 $1655.00 $2216.00 CL09 CL07 138 40 50 100 125 LAD09A $1518.00 $1826.00 $1946.00 $2552.00 CL10 CL07 180 60 60 125 125 LAD10A $1842.00 $2150.00 $2270.00 $2878.00 CK75 CK75 230 75 75 150 200 KAD75C $2981.00 $3975.00 $4413.00 $5861.00 CK08 CK75 270 75 100 200 250 KAD08C $3626.00 $4618.00 $5058.00 $6506.00 CK09 CK09 332 100 125 250 300 KAD09B $4584.00 $5576.00 $6028.00 $7464.00 CK95 CK09 523 150 200 400 500 $5622.00 $6614.00 $7066.00 $8502.00 CK10 CK10 689 250 250 500 700 KAD95B KAD10C1 $9238.00 $10717.00 $11289.00 $13277.00 CK11 CK10 831 300 300 600 800 KAD11C1 $12138.00 $13617.00 $14189.00 $16180.00 CK12 CK12 1042 400 400 800 1000 KAD12B $15238.00 $16717.00 $17309.00 $19280.00 1 Maximum fuse 1000A, maximum circuit breaker 600A Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-105 IEC Power Devices Section 5 IEC Assembled Starters Wye-Delta Open Transition AC C-2000 Step-By-Step Selection and Pricing À Select Coil Voltage à Select Overload Type Select coil based on control circuit voltage or, if you plan to add a control power transformer (step “), on primary circuit voltage instead. Transfer the product number digit to the boxes marked À in the product number line. Note that there is no price component to this step. Select overload type. Transfer the product number digit to the box marked à in the product number line. Note that there is no price component to this step. Coil (control circuit voltage) For Prod. Nos. beginning with LAD 60 Hz Primary Circuit Voltage (for CPT) For Prod. Nos. beginning with KAD 50 Hz Product Number Digit 60/50 Hz (AC/DC) For Product Numbers beginning LAD Overload Type None Manual/ Automatic Reset Product Number Digit Prod. No. Digit Primary volts For Prod. Nos. beginning with LAD For Prod. Nos. beginning with KAD 24 24 — 1 — — — — — 24-28 D — — — 48 42 42-48 F — — — 120 110 110-127 J — — — 208 — — L 208 L L 277 220/230 220-250 N 220-240 S N — 240 — — S — — 480 380/400 380-415 U 480 U Y — 415 — W — — — 600 500 440-500 Y 600 Y Z For Product Numbers beginning KAD Z Z Class 10 W W Class 30 — F Õ Select Overload Rating From among the columns that correspond both to your product number from step ∂ and to the overload class (10 or 30) from step Ã, select the specific amp range (be sure to observe the maximum FLA rating for your starter as indicated in step ∂). Transfer the product number digit to the box marked Õ in the product number line and the price to the box marked Õ in the price line. To select overload range for wye-delta starter, multiply motor amps by 0.58. Class 10 For Product Nos. beginning LAD00-LAD45 Overload Amp Range List Price Adder, GO-10CA For Product Nos. beginning LAD06-LAD10 Overload Amp Range List Price Adder, GO-10CA Class 30 For Product Nos. beginning KAD75-KAD08 Overload Amp Range For Product Nos. beginning KAD09-KAD95 For Product Nos. beginning KAD10-KAD12 List Price Adder, GO-10CA Overload Amp Range List Price Adder, GO-10CA Overload Amp Range For Product Nos. beginning KAD09-KAD95 List Price Adder, GO-10CA Overload Amp Range List Price Adder, G0-10CA For Product Nos. beginning KAD10-KAD12 Overload Amp Range List Price Adder, G0-10CA Prod. No. Digit — — 11.5-15 $98.00 — — — — 120-190 $641.00 — — 120-190 $641.00 A 0.16-.26 $55.00 14.5-19 $98.00 55-80 $185.00 — — 175-280 $641.00 — — 175-280 $641.00 B 0.25-.41 $55.00 18.5-25 $98.00 63-90 $185.00 — — 250-400 $641.00 — — 250-400 $641.00 C 0.4-.65 $55.00 24-32 $98.00 90-120 $185.00 — — 315-500 $903.00 — — 315-500 $903.00 D E — — 30-43 $98.00 110-140 $225.00 — — 430-650 $903.00 — — 430-650 $903.00 .65-1.1 $55.00 — — 140-190 $225.00 — — — — — — — — F 1-1.5 $55.00 42-55 $98.00 — — — — — — — — — — G 1.3-1.9 $55.00 54-65 $98.00 — — — — — — — — — — H 1.9-2.7 $55.00 64-82 $117.00 — — — — — — — — 2.5-4.1 $55.00 — — — — — — — 45-70 $285.00 — — — — K — J 4-6.3 $55.00 78-97 $143.00 — — — — — — 60-90 $285.00 — — L 5.5-8.5 $57.00 90-110 $143.00 — — — — — — 80-125 $285.00 — — M N 8-12 $57.00 — — — — 120-190 $285.00 — — 120-190 $285.00 — — 10-16 $57.00 — — — — 175-280 $285.00 — — 175-280 $285.00 — — P — — — — — — 200-310 $380.00 — — 200-310 $380.00 — — R 14.5-18 $57.00 — — — — — — — — — — — — S 17.5-22 $57.00 — — — — — — — — — — — — T 21-26 $57.00 — — — — — — — — — — — — U 25-32 $65.00 — — — — — — — — — — — — V 30-40 $78.00 — — — — — — — — — — — — W None 0 None 0 None 0 — — None 0 None 0 None 0 Z This is the last step in selection of open starters. 5-106 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Wye-Delta Open Transition AC C-2000 Step-By-Step Selection and Pricing Œ Select Enclosure œ Select Operator Select enclosure. Transfer the product number digit to the box marked Œ in the product number line and the price to the box marked Œ in the price line. Note that your enclosure selection here MUST agree with that made in step ∂. Note, too, that the price component for this step is $0.00 for units with reset and $8.00 subtraction for units without reset. Select operator. Transfer the product number digit to the box marked œ in the product number line and the price to the box marked œ in the price line. Be sure your selection agrees with your contactor selection in step ∂. Product Number Digit NEMA Type NEMA Types 12/3R NEMA Type 4 Operator Product Number Digit List Price Adder, GO-10CA None A $ 0.00 List Price Subtraction, GO-10CA START-STOP push button B $110.00 HOA selector switch C $110.00 ON-OFF selector switch D $110.00 With reset 1 2 4 $0.00 Without reset 5 6 8 (8.00) This is the last step required for selection of enclosed starters. If desired, select operators, indicating lights and CPTs in steps 6 to 8 . – Select Indicating Light Select indicating light. Transfer the product number digit to the box marked – in the product number line and the price to the box marked – in the price line. Be sure your selection agrees with your contactor selection in step ∂. Indicating Light Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Product Number Digit List Price Adder, GO-10CA None A $0.00 Red RUN across coil B $75.00 Red RUN across coil & green STOP across NC auxiliary contact D $97.00 Red RUN & yellow START across coil H $150.00 Red RUN & yellow START across coil & green STOP across NC auxiliary contact J $225.00 Control Catalog 5-107 IEC Power Devices Section 5 IEC Assembled Starters Wye-Delta Open Transition AC C-2000 Step-By-Step Selection and Pricing — Select Control Power Transformer Select control power transformer. Transfer the product number digit to the box marked — in the product number line and the price to the box marked — in the price line. Be sure your selection agrees with your contactor selection in step ∂. CPT VA For Product Numbers beginning with LAD For Product Numbers beginning with KAD Standard 50 250 Extra VA 150 300 For Product Nos. beginning LAD Prod. No. Digit Control Power Transformer For Product Nos. beginning KAD List Price Adder, GO-10CA Prod. No. Digit None — $0.00 — $0.00 Fused control circuit (without control transformer)—one fuse B $110.00 B $110.00 Separate control circuit C $0.00 C $0.00 Fused separate control circuit (one fuse) D $110.00 D $110.00 Control transformer, standard capacity, 110-120 V 50/60 Hz secondary voltage, one secondary fuse, two primary fuses F $300.00 F $450.00 Control transformer, extra capacity, 110-120 V 50/60 Hz secondary voltage, one secondary fuse, two primary fuses H $390.00 H $590.00 -----------------------------------------------------Minimum steps for enclosed starter--------------------------------------------------------------------------------------------Maximum steps for open starter------------------------------------------ Product List Price Adder, GO-10CA r Optional steps for enclosed ---------------starter-------------- A Price $ +0 +0 + +0 = - + Complete Prod. No. + + = $ Total List Price, GO-10CA Note: Product Number should not end in a "None" option. For example, KAD08CJZZA should be KAD08CJ. Control Circuit Fusing Per the NEC and UL508 Section 18.2 - Control Circuit Fuses must be used when the branch circuit protective device rating is too large to serve as protection for the control circuit. This depends on the control wire size and whether all control circuit wires are within the enclosure. See table below: The factory must provide this protection, if the circuit provided by the factory requires the fuses. The factory will provide control circuit fuses in enclosed starters and contactors with pilot devices, control relays or other control components that are factory wired; when used with line voltage control; when the size listed below is being supplied. Provide supplemental control circuit protection if control circuits with wires longer than 12 inches are connected to branch circuit protection exceeding the ratings below Non-combination starters (LAC, LAR, LAD, KAC, KAR, KAD) Supplied with: —CL10 Contactors and Larger —Overload Relays 90 amps and larger Control Circuit fuses must be added to the enclosed starter or contactor pricing. Control Circuit Wire Size (AWG) 22 20 18 16 14 12 5-108 Maximum Branch Circuit Protection Rating (Amperes) Conductors Conductors within Enclosure outside Enclosure 12 20 25 40 100 120 3 5 7 10 45 60 Control Catalog Maximum Supplemental Control Circuit Protection Rating (Amperes) 3 5 7 10 20 25 All CPTs in enclosed control will be supplied with primary fuses. CPTs without primary fuses are no longer available. When control circuit fuses are not factory supplied, customer provided wiring or branch circuit protection sizing to these contactors and starters may still require that the customer/installer add the fusing in the field. It will be the customer/installer’s responsibility to ensure code compliance under these conditions. www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice IEC Power Devices Section 5 IEC Assembled Starters Enclosures C-2000 NEMA Type 1 (General-Purpose) NEMA Types 12/3R (Oil-, Dust-, and Rain-Tight) NEMA Type 4 (Water-Tight) Dimension Legend D W H Enclosures For CL Contactors—Dimensions and Outlines Note: Enclosures are designed for use with ac contactors without front-mounted accessories. Order CL25, CL45, and CL06-CL10 contactors with side-mounted auxiliary contacts for use in these enclosures. Type 1 12/3R 4 Product Number Basic Enclosure Dimensions (in inches) Assembled Starter Product Number For Use With CLXE1A LAC00-45 CL00-45 Starter without 10 CLXE1B LAC05-08 CL05-08 Starter without 13.3 CLXE1C LAC09-10 CL09-10 Starter without 20.3 CLXE1D LAC00-45 CL00-45 Starter with CLXE1E LAC05-08 CL05-08 Starter with With or Without CPT D Outline Number 6 4.6 55-215878 7.4 6.1 55-215895 8.8 7.3 55-215880 10 10 4.6 55-215879 13.3 12 6.1 55-215896 H W CLXE1F LAC09-10 CL09-10 Starter with 25 8.8 7.3 55-215898 CLXE1G LAR00-45 CL00-45 Reverser with 16.8 15 6.9 55-215894 CLXE1G LAD00-45 CL00-45 Wye-Delta without 16.8 15 6.9 55-215894 CLXE1H LAR05-10 CL05-10 Reverser with 20.3 16.8 6.6 55-215897 CLXE1L LAD05-10 CL05-10 Wye-Delta without 27 22 8.6 55-215893 CLXE2A LAC00-45 CL00-45 Starter without 14.5 6.4 5.5 55-215875 CLXE2B LAC05-10 CL05-10 Starter without 16.5 7.8 6.25 55-215891 CLXE2C LAC00-45 CL00-45 Starter with 14.5 10.4 5.5 55-215888 CLXE2C LAR00-45 CL00-45 Reverser without 14.5 10.4 5.5 55-215888 CLXE2D LAC05-10 CL05-10 Starter with 16.5 12.5 6.25 55-215889 CLXE2D LAR05-10 CL05-10 Reverser without 16.5 12.5 6.25 55-215889 CLXE2E LAR00-45 CL00-45 Reverser with 14.5 14.4 5.5 55-215892 CLXE2F LAR05-10 CL05-10 Reverser with 17 16.5 6.25 55-215890 CLXE2G LAD00-45 CL00-45 Wye-Delta with or without 17 16.5 6.5 55-215887 CLXE2H LAD05-10 CL05-10 Wye-Delta with or without 22 21.2 8 55-215886 CLXE4A LAC00-45 CL00-45 Starter without 17 7.75 6.5 55-215867 CLXE4B LAC05-10 CL05-10 Starter without 17 7.75 6.5 55-215866 CLXE4C LAC00-45 CL00-45 Starter with 14.5 10.5 5.5 55-215865 CLXE4C LAR00-45 CL00-45 Reverser without 14.5 10.5 5.5 55-215865 CLXE4D LAC05-10 CL05-10 Starter with 17 12.5 6.25 55-215864 CLXE4D LAC05-10 CL05-10 Reverser without 17 12.5 6.25 55-215864 CLXE4E LAR00-45 CL00-45 Reverser with 16.5 16.5 6.5 55-215863 CLXE4F LAR05-10 CL05-10 Reverser with 17 16.5 6.5 55-215862 CLXE4E LAD00-45 CL00-45 Wye-Delta with 17 16.5 6.5 55-215863 CLXE4H LAD05-10 CL05-10 Wye-Delta with 26 18 8.0 55-215860 Rev. 7/13 Prices and data subject to change without notice www.geindustrial.com Control Catalog 5-109 IEC Power Devices Section 5 IEC Assembled Starters Enclosures C-2000 NEMA Type 1 (General-Purpose) NEMA Types 12/3R (Oil-, Dust-, and Rain-Tight) NEMA Type 4 (Water-Tight) Dimension Legend D W H Enclosures For CK Contactors—Dimensions and Outlines CK enclosures are only supplied with complete factory-assembled contactors and starters. Dimensions (in inches) Type 1 12/3R 4 5-110 Assembled Starter Product Number For Use With With or Without CPT H W D Outline Number KAC75-08 CK75-08 Starter with or without 28 KAC09-95 CK09-95 Starter with or without 36 14 9 55-216404 17 12 KAC10-12 CK10-12 Starter with or without 55-215859 46 20 15.5 55-215858 55-216404 KAR75-08 CK75-08 Reverser with or without 28 14 9 KAR09-95 CK09-95 Reverser with or without 36 17 12 55-215859 KAR10-12 CK10-12 Reverser with or without 46 26 15.5 55-215857 KAD75-08 CK75-08 Wye-Delta with or without 32 22 9 55-216405 KAD09-95 CK09-95 Wye-Delta with or without 48 30 12 55-215856 KAD10-12 CK10-12 Wye-Delta with or without 56 36 15.5 55-215855 KAC75-08 CK75-08 Starter with or without 28 18 9 55-216406 KAC09-95 CK09-95 Starter with or without 36 22 12 55-215854 KAC10-12 CK10-12 Starter with or without 46 20 15.5 55-215858 55-216406 KAR75-08 CK75-08 Reverser with or without 28 18 9 KAR09-95 CK09-95 Reverser with or without 36 22 12 55-215854 KAR10-12 CK10-12 Reverser with or without 46 26 15.5 55-215857 KAD75-08 CK75-08 Wye-Delta with or without 32 22 9 55-216407 KAD09-95 CK09-95 Wye-Delta with or without 48 30 12 55-215851 KAD10-12 CK10-12 Wye-Delta with or without 56 36 15.5 55-215850 KAC75-08 CK75-08 Starter with or without 28 18 9 55-216408 KAC09-95 CK09-95 Starter with or without 36 22 12 55-215849 KAC10-12 CK10-12 Starter with or without 46 20 15.5 55-215848 55-216408 KAR75-08 CK75-08 Reverser with or without 28 18 9 KAR09-95 CK09-95 Reverser with or without 36 22 12 55-215849 KAR10-12 CK10-12 Reverser with or without 46 27 15.5 55-215847 KAD75-08 CK75-08 Wye-Delta with or without 32 22 9 55-216409 KAD09-95 CK09-95 Wye-Delta with or without 48 30 12 55-215846 KAD10-12 CK10-12 Wye-Delta with or without 56 36 15.5 55-215845 Control Catalog www.geindustrial.com Rev. 7/13 Prices and data subject to change without notice
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : GE Energy Create Date : 2007:04:26 10:40:05-04:00 Modify Date : 2014:01:27 10:39:55-05:00 Subject : Electrical Distribution - General Purpose Control Components Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 7.0 for Macintosh Keywords : Creator Tool : QuarkXPress: pictwpstops filter 1.0 Metadata Date : 2014:01:27 10:39:55-05:00 Document ID : uuid:81fe1353-f405-11db-920e-0003935a4c8c Instance ID : uuid:2d475cc4-2ae7-7844-a7d8-ba2b49e51539 Web Statement : http://www.geindustrial.com/cwc/aboutus/terms_of_use.htm Marked : True Format : application/pdf Title : GE Control Catalog - Section 5: IEC Power Devices Description : Electrical Distribution - General Purpose Control Components Rights : © 2011 General Electric Company Creator : GE Energy Startup Profile : Print Page Layout : SinglePage Page Mode : UseOutlines Page Count : 110EXIF Metadata provided by EXIF.tools