F_section 138575 Catalog

2016-10-27

: Pdf 138575-Catalog 138575-Catalog B6 unilog

Open the PDF directly: View PDF PDF.
Page Count: 160

DownloadF_section  138575-Catalog
Open PDF In BrowserView PDF
Industrial Fittings

Section F

Time-tested and innovative conduit fittings, cord connectors and cable
glands move power where you need it simply and safely in any
electrical installation.

New Products in the Industrial Fittings Product Line

Section

• Terminator™ II TMCX Cable Glands

4F

Electrical Fittings

F

F

Table of Contents

Section F of the Eaton's Crouse-Hinds Product Catalog lists a wide
variety of conduit outlet bodies and boxes, cable fittings, unions,
connectors, seals, breathers, and drains for both hazardous and
non-hazardous area use. Information on applications, features,
standard materials, standard finishes, options, size ranges,
compliances, and accessories is presented for ease of product
selection. Information relating to product families in Section F is
grouped as follows:

Section 1F

Section 4F
Cable Glands and Cable Accessories
(for hazardous and non-hazardous areas)
Includes listings of cable and cord connectors and cable
terminators for armoured and unarmoured cable and cord, and
aluminum sheathed cable. Used to:
• Provide means for passing cord, cable or flexible conduit through
bulkhead and into boxes and cabinets
• Form watertight seal

Condulet® Conduit Bodies and Outlet Boxes
(for non-hazardous areas)
Conduit bodies for installation in conduit systems to act as pull
outlets, make 90° bends, provide for splices, taps, mounting
outlets, etc.
Form 7
Mogul
SLB
Form 8
LBD
LBY
Mark 9
LBNEC
ET
Form 5
Series 5
Form 7 SnapPack™
Round cast outlet boxes and accessories for use in conjunction
with threaded rigid conduit to serve as junction boxes, pull outlets,
accommodate wiring devices and support lighting fixtures.
GRF
VXF

• Form non-slip connection or termination for flexible cord, cable or
flexible conduit
• Provide grounding continuity
ADE
ADE
ADE
ADE

1F
4F
6F
1FC

ADE 6FC
CGB
CGFP
EBY

LCC
LCCF
TGC
THRU-WALL

TMC
Terminator™ II TMCX
TMCX

Section 5F
Elbows, Couplings, Hubs, Grounding Devices,
Plugs, Reducers, Service Entrance and Unions
(for hazardous and non-hazardous areas)
Includes:
• Service entrance heads

Section 2F

• Grounding receptacles and straps

Condulet Device Boxes

• Unions and elbows for threaded conduit systems

(for non-hazardous areas)
For installation in conduit systems to:
• Accommodate wiring devices

• Couplings for use where allowance must be made in conduit
system for difficult bends or vibration

• Act as pull boxes

• Plugs for unused conduit openings and hubs

• Reducers for connecting conduit of different dimensions

• Provide openings for taps and splices
Provided in two box depths with a wide variety of hub
configurations and sizes. Boxes can accommodate single or
multiple devices.
FS
FD
Covers

ECGJH
ECLK
EL
F

GC
GCR
GCT
HUBS

LNR
PLG
RE
REC

UNA
UNF
UNFL
UNL

UNY
UNYL
XD
XJG

Section 6F

Section 3F

Seals, Breathers and Drains

Condulet Conduit Bodies and Outlet Boxes
(for hazardous areas)
For use with rigid conduit systems:
• Act as pull and splice boxes

(for hazardous areas)
Includes:
• Seals used to prevent passage of gases or flames in conduit runs
and from device enclosures
• Sealing/drain fittings for retrofit applications

• Act as mounting outlets or supports for lighting fixtures

• Breathers used to provide ventilation for enclosures

• Act as sealing fittings

• Drains used to prevent accumulation of moisture in conduit
systems and enclosures
• Chico® sealing compound and fiber

CPS
EAB
EKC

2

ET
GUA
HTL

www.crouse-hinds.com

LBH
LBY
OE

US: 1-866-764-5454

STL
EAJ
GUR

CAN: 1-800-265-0502

Seal
Seal and drain
EYS
EYD
EZS
EZD
EYSR
EYDX
EYSX
Secondary Process Sealing Fitting
EYS Tool Kit

Copyright© 2013 Eaton’s Crouse-Hinds Business

Breather
and drain
ECD
CD

1F

Condulet® Conduit Bodies and Outlet Boxes
Non-Hazardous

Page No.
see page 4

Shape Selector Chart

see page 5

Conduit Bodies - Cast Iron or Aluminum
Forms 7 & 8, Mark 9, Series 5 and Form 5
Form 7 SnapPack™
Mogul Series
LBD Series
LBNEC Mogul Pulling Elbows

see pages 6–81
see page 9
see pages 13–14
see page 15
see page 16

Covers for Cast Iron or Aluminum Conduit Bodies
Blank
Forms 7 & 8, Mark 9, Series 5 and Form 5
Mogul Series

see page 8
see pages 13–14

Gaskets for Cast Iron or Aluminum Conduit Bodies
Forms 7 & 8, Mark 9, Series 5 and Form 5
LBD Series
Mogul Series

see page 8
see page 15
see pages 13–14

Conduit Bodies, Covers and Gaskets - Stainless Steel

see pages 17–27

Condulet® Outlet Boxes
GRF Series
VXF Series

see page 19
see page 19

Service Entrance Elbows & Tees
ET Tees
LBY & SLB Elbows

www.crouse-hinds.com

US: 1-866-764-5454

see page 20
see page 20

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

3

1F

Application/Selection

1F

Description

1F

Condulet® Conduit Bodies and Outlet Boxes

1F

Application and Selection

Applications:

Considerations for Selection:

Conduit bodies and outlet boxes are installed at appropriate
locations in threaded rigid conduit systems to:
• Act as pull outlets for conductors to be installed in a conduit
system
• Provide openings for splices and taps in conductors
• Act as mounting outlets for luminaires and wiring devices, or as
support for luminaires (with hub and fixture hanging covers)
• Act as junction or fuse boxes when fitted with connection blocks
or fuse blocks
• Connect conduit sections and change direction of conduit runs
• Make 90º bends in conduit runs
• Provide access to conductors for maintenance and future
system changes

• Shape required – determine from configuration of conduit system
and intended function of conduit bodies or outlet boxes
• Size required – determine from conduit and conductor size
• Material required – determine from environmental conditions
(corrosive fumes, buried in concrete, etc.)

Quick Selector Chart - Conduit Bodies
Conduit
Sizes
1
/2" - 4"

Series
Form 7

Standard
Material
Feraloy® iron or aluminum

Configuration Styles
C, E, L, LB, LL, LR, T,
TA, TB and X

/2" - 4"

C, LB, LL, LR, T, TB and X

Feraloy iron

/2" - 4"

C, LB, LL, LR, T, TB and X

Copper-free aluminum

/2" - 4"

C, LB, LL, LR, T, TB and X

Durable malleable iron construction

/2" - 4"

C, LB, LL, LR and T

Corrosion-resistant copper-free aluminum construction

Form 8

1

Mark 9

1

Form 5

1

Series 5

1

Quick Selector Chart - Conduit Outlet Boxes
Inside
Dimensions

Series
VXF

GRF

4

Conduit
Sizes
1
/2 and 3/4

Depth
13/4

/2 to 1

13/8 to 31/8

1

www.crouse-hinds.com

Dia.
41/4

No. of
Conduit
Openings
4 or 5

Surface
or Flush
Mtg.
S

311/16

0 to 4

S–F

US: 1-866-764-5454

CAN: 1-800-265-0502

Standard
Material
Copper-free
aluminum
Feraloy iron
alloy or
aluminum

Finish
Epoxy enamel

Covers
When box is used as
junction or pull box,
install GRF covers, gaskets.

Electrogalvanized
and aluminum paint

Blank, hub, standard
4" octagonal box
covers, wiring devices,
lighting fixture
hangers, gaskets.

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Bodies and Outlet Boxes

1F

Shape Selector Chart

Form 7
Form 8
Mark 9
Form 5
Series 5

Page

see
see
see
see
see

pages
pages
pages
pages
pages

6–12
6–12
6–12
6–12
6–12

E

Form 7

Form 7
Form 8
Mark 9
Form 5
Series 5

pages
pages
pages
pages
pages

6–12
6–12
6–12
6–12
6–12

see
see
see
see
see

pages
pages
pages
pages
pages

6–12
6–12
6–12
6–12
6–12

pages
pages
pages
pages
pages

6–12
6–12
6–12
6–12
6–12

Outlet Box

Mogul
see
see
see
see

pages
pages
pages
pages

6–12
6–12
6–12
6–12

X

see page 19

see pages 13–14

LBD

/2 – 1"

1

see page 15

LBD
Form 7
Form 8
Mark 9
Form 5

see
see
see
see
see

Page

BT

Form 7
Form 8
Mark 9
Form 5
see
see
see
see
see

Series
GRF

see pages 6–12

LL

Form 7
Form 8
Mark 9
Form 5
Series 5

Page

TB

LB

Form 7
Form 8
Mark 9
Form 5
Series 5

Series
T

see
see
see
see

pages
pages
pages
pages

6–12
6–12
6–12
6–12

see page 15

SLB

LBNEC

LBNEC

11/4 – 6"

see page 16

LR

Service Entrance Elbows

see page 20

BC
LBY
Form 7
Form 8
Mark 9
Form 5
Series 5

see
see
see
see
see

pages
pages
pages
pages
pages

6–12
6–12
6–12
6–12
6–12

Mogul

see pages 13–14

BLB

Service Entrance Elbows

L
Mogul

see pages 13–14

see page 20

ET

BUB
Form 7

see pages 6–12
Mogul

see pages 13–14

TA

Service Entrance Elbows

see page 20

VXF

Form 7

see pages 6–12

Outlet Box

www.crouse-hinds.com

US: 1-866-764-5454

see page 19

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

5

1F

Series
C

1F

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

Gasket and Covers see page 8
Applications:

Certifications and Compliances:

Conduit outlet bodies are installed in conduit systems to:

Outlet Bodies –
• UL Standard: 514B
• Fed. Spec.: W-C-586D
• CSA Standard 22.2 No. 18
• NEMA 3R Raintight (when installed with cover and gasket)

• Act as pull outlets for conductors being installed
• Provide openings for making splices and taps in conductors
• Connect conduit sections
• Provide taps for branch conduit runs
• Make 90° bends in conduit runs

Standard Materials:

• Provide for access to conductors for maintenance and future
system changes

•
•
•
•

Features:

Form 7, Form 8 outlet bodies – Feraloy iron alloy
Mark 9 outlet bodies – copper-free aluminum
Form 5 – malleable iron
Series 5 – die cast aluminum

Conduit Outlet Bodies

Standard Finishes:

• Form 7 Condulet outlet bodies approach conduit in size for neat,
compact installations

• Many shapes and sizes are available for rigid threaded conduit –
for complete listings see pages 6–12

• Form 7, Form 8 outlet bodies – electrogalvanized with aluminum
acrylic paint
• Mark 9 outlet bodies – natural
• Form 5 – electrogalvanized with aluminum acrylic paint
• Series 5 – aluminum acrylic paint

• Conduit hubs have tapered threads and feature integral bushings
for protection of wire insulation

Options:

• Form 8 and Mark 9 bodies provide more room for heavier
conductors

• Form 7 has exclusive snaptight and wedgenut cover attachment to
provide clear, unobstructed cover opening
• Built-in rollers on all Form 5 11/4" to 4" C and LB bodies to
facilitate wire pulling
• Series 5 bodies available in optional configuration with set screws
on hubs for EMT conduit (add suffix -MT to catalog number)

Description
Suffix
Form 7 body and cover only:
Copper-free aluminum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SA
Corro-free™ epoxy powder coat - external body only . . . . . . . . . S752
Corro-free™ epoxy powder coat - internal and external . . . . . . . S753
Series 5 in an EMT version with set screws on all hubs . . . . . . . MT
Series 5 pre-packaged with neoprene gasket and cover . . . . . . CGN

Gaskets
Solid gaskets:
• Are used with blank covers
• For Mark 9 and Form 5, can be converted to open type gaskets by
tearing out center section along scored lines – 1/2" to 2" sizes
• For Form 7 are used with all covers

Form 7

Open gaskets:
• For Form 8 – 1/2" to 4" sizes
• For Mark 9 – 21/2" to 4" sizes

Blank Covers
Stainless steel cover screws are standard on Form 7, Form 8,
Mark 9, Series 5 and Form 5 covers.

Mark 9

• Form 7
Wedge nut design facilitates installation and removal. Nuts are held
captive in cover. Covers can be used with or without gaskets.
SNAPTIGHT™ Form 7 Covers with integral sealing gaskets are
installed without the use of screws, reducing installation time and
costs. Covers are reusable.

Form 8

• Form 8
Two cover screws provided on all sizes to provide tight cover and
gasket assembly. Feraloy iron alloy covers have dome shapes for
added strength and extra wiring room.
• Mark 9
Mogul

Self-retaining cover screws.

6

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

Dimensions Pgs. See pages 10–12 (Dimensions for Form 5 – see Section CP)

Shape

1F

Threaded Rigid Bodies
Style
C
Form 7
Form 8
Mark 9
Form 5
Series 5

Hub Size
1
3
/2
/4

1

11/4

11/2

2

21/2

3

31/2

4

C17
C18
C19
C50M
C15

C27
C28
C29
C75M
C25

C37
C38
C39
C100M
C35

C47
C448
C49
C125M*
C45

C57
C58
C59
C150M*
C55

C67
C68
C69
C200M*
C65

C77
C78
C789
C250M*
C75

C87
C88
C889
C300M*
C85

C989
C350M*
C95*

C1089
C400M*
C105*

E
Form 7

E17

E27

E37

L
Form 7

L17

L27

L37

L47

L57

L67

Double faced – may be used as LL or LR – has 2 openings, one of which is furnished with a blank sheet steel cover
LB
Form 7
Form 8
Mark 9
Form 5
Series 5

LB17
LB18
LB19
LB50M
LB15

LB27
LB28
LB29
LB75M
LB25

LB37
LB38
LB39
LB100M
LB35

LB47
LB448
LB49
LB125M*
LB45

LB57
LB58
LB59
LB150M*
LB55

LB67
LB68
LB69
LB200M*
LB65

LB777
LB78
LB789
LB250M*
LB75

LB87
LB888
LB889
LB300M*
LB85

LB97
LB98
LB989
LB350M*
LB95

LB107
LB108
LB1089
LB400M*
LB105

LL
Form 7
Form 8
Mark 9
Form 5
Series 5

LL17
LL18
LL19
LL50M
LL15

LL27
LL28
LL29
LL75M
LL25

LL37
LL38
LL39
LL100M
LL35

LL47
LL448
LL49
LL125M
LL45

LL57
LL58
LL59
LL150M
LL55

LL67
LL68
LL69
LL200M
LL65

LL777
LL78
LL789
LL250M
LL75

LL87
LL888
LL889
LL300M
LL85

LL97

LL107

LL989
LL350M
LL95

LL1089
LL400M
LL105

LR
Form 7
Form 8
Mark 9
Form 5
Series 5

LR17
LR18
LR19
LR50M
LR15

LR27
LR28
LR29
LR75M
LR25

LR37
LR38
LR39
LR100M
LR35

LR47
LR448
LR49
LR125M
LR45

LR57
LR58
LR59
LR150M
LR55

LR67
LR68
LR69
LR200M
LR65

LR777
LR78
LR789
LR250M
LR75

LR87
LR888
LR889
LR300M
LR85

LR97

LR107

LR989
LR350M
LR95

LR1089
LR400M
LR105

T
Form 7
Form 8
Mark 9
Form 5
Series 5

T17
T18
T19
T50M
T15

T27
T28
T29
T75M
T25

T37
T38
T39
T100M
T35

T47
T448
T49
T125M
T45

T57
T58
T59
T150M
T55

T67
T68
T69
T200M
T65

T77
T78
T789
T250M
T75

T87
T88
T889
T300M
T85

T97

T107

T989
T350M
T95*

T1089
T400M
T105*

TA
Form 7

TA17

TA27

TA37

TA47

TA57

TA67

TB
Form 7
Form 8
Mark 9
Series 5
Form 5

TB17
TB18
TB19
TB15
TB50M

TB27
TB28
TB29
TB25
TB75M

TB37
TB38
TB39
TB35
TB100M

TB47
TB448
TB49
TB45
TB125M

TB57
TB58
TB59
TB55
TB150M

TB67
TB68
TB69
TB65
TB200M

X
Form 7
Form 8
Mark 9
Series 5
Form 5

X17
X18
X19
X15
X50M

X27
X28
X29
X25
X75M

X37
X38
X39
X35
X100M

X47
X448

X57
X58

X67
X68

X45
X125M

X55
X150M

X65
X200M

* 11/4" - 4" Form 5 LB and C bodies are supplied with built-in rollers to facilitate wire pulling.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

7

1F

Condulet® Conduit Bodies - Cast Iron or Aluminum

1F

Covers and Gaskets
Dimensions Pgs. See pages 10–12 (Dimensions for Form 5 – see Section CP)

Blank Covers

Sheet Steel

Size

Form 7
Wedgenut
Cat. #

/2
/4
1
11/4
11/2
2
21/2
3
31/2
4

170
270
370
470
570
670
870
870
970
970

1
3

Form 7
Snaptight™
Covers‡
Cat. #

Form 7
Wedgenut
w/Integral Gasket
Cat. #

170SG
270SG
370SG
470SG
570SG
670SG
870G

170G
270G
370G
470G
570G
670G

Form 8§
Cat. #
180
280
380
480
580
680
880
880
980
980

970G

Form 8
w/Integral
Gasket
Cat. #

Form 5
w/Integral
Gasket**
Cat. #

180G
280G
380G
480G
580G
680G

K50SG
K75SG
K100SG
K125SG
K125SG
K200SG
K250SG
K250SG
K350SG
K350SG

‡Form 7 Snaptight covers with integral sealing gasket are installed without the use of screws.
§Two cover screws on 1/2" to 2" Form 8 covers and four cover screws on 21/2" and larger Form 8 covers.
**For cover without integral gasket, remove G from catalog number.

Sheet Aluminum

Mark 9
Size Cat. #
/2
/4
1
11/4
11/2
2
21/2
3
31/2
4

1
3

190
290
390
490
590
690
889
889
989
989

Mark 9
w/Integral
Gasket
Cat. #
190G
290G
390G
490G
590G
690G

Form 7
Cat. #
170
270
370
470
570
670
870
870
970
970

SA
SA
SA
SA
SA
SA
SA
SA
SA
SA

Feraloy® Iron Alloy

Form 7
w/Integral
Gasket
Cat. #

Series 5
w/Integral Form 7
Gasket** Wedgenut
Cat. #
Cat. #

170G
270G
370G
470G
570G
670G

150
250
350
450
450
650
850
850
950
950

SA
SA
SA
SA
SA
SA

G
G
G
G
G
G
G
G
G
G

170F
270F
370F
470F
570F
670F
870F
870F
970F
970F

Form 7
Wedgenut
w/Integral
Gasket
Cat. #
170FG
270FG
370FG
470FG
570FG
670FG

Cast Aluminum

Form 8§
Cat. #

Form 5‡
Cat. #

Form 7
Wedgenut
Cat. #

180F
280F
380F
480F
580F
680F
880F
880F
980F
980F

K50CM
K75CM
K100CM
K125CM
K125CM
K200CM
K250CM
K250CM
K350CM
K350CM

170F
270F
370F
470F
570F
670F
870F
870F
970F
970F

SA
SA
SA
SA
SA
SA
SA
SA
SA
SA

‡Malleable iron covers.
§Two cover screws on 1/2" to 2" Form 8 covers and four cover screws on 21/2" and larger Form 8 covers.
**For cover without integral gasket, remove G from catalog number.

Solid Gaskets - Neoprene

Size

Form 7
Cat. #

Form 8*
Cat. #

Mark 9†
Cat. #

Form 5
Cat. #

Series 5
Cat. #

/2
/4
1
11/4
11/2
2
21/2
3
31/2
4

GASK571
GASK572
GASK573
GASK574
GASK575
GASK576
GASK578
GASK578
GASK579
GASK579

GASK851N
GASK852N
GASK853N
GASK854N
GASK805N
GASK806N
GASK808N
GASK808N
GASK809N
GASK809N

GASK1941
GASK1942
GASK1943
GASK1944
GASK1945
GASK1946
GASK808N
GASK808N
GASK809N
GASK809N

GK50N
GK75N
GK100N
GK125N
GK125N
GK200N
GK250N
GK250N
GK350N
GK350N

GASK015N
GASK025N
GASK035N
GASK045N
GASK045N
GASK065N
GASK085N
GASK085N
GASK095N
GASK095N

1
3

*1/2 – 11/4 are solid gaskets; 11/2 – 4 are open gaskets.
†1/2 – 2 are solid gaskets; 21/2 – 4 are open gaskets.

8

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Bodies - Cast Iron or Aluminum

1F

Form 7 SnapPack™
Pre-Assembled Body, Gasket and Cover

Ordering Information

Form 7 Condulets are installed in conduit
systems to:

Trade
Size

Shape

Cat. #

• Act as pull outlets for conductors being
installed

1

/2"
3
/4"
1"
11/4"
11/2"
2"

C
C
C
C
C
C

C17
C27
C37
C47
C57
C67

/2"
/4"
1"
11/4"
11/2"
2"

LB
LB
LB
LB
LB
LB

LB17
LB27
LB37
LB47
LB57
LB67

CG
CG
CG
CG
CG
CG

/2"
/4"
1"
11/4"
11/2"
2"

LL
LL
LL
LL
LL
LL

LL17
LL27
LL37
LL47
LL57
LL67

CG
CG
CG
CG
CG
CG

/2"
/4"
1"
11/4"
11/2"
2"

LR
LR
LR
LR
LR
LR

LR17
LR27
LR37
LR47
LR57
LR67

CG
CG
CG
CG
CG
CG

/2"
/4"
1"
11/4"
11/2"
2"

T
T
T
T
T
T

T17
T27
T37
T47
T57
T67

/2"
/4"
1"
11/4"
11/2"
2"

TB
TB
TB
TB
TB
TB

TB17
TB27
TB37
TB47
TB57
TB67

/2"
/4"
1"
11/4"
11/2"
2"

X
X
X
X
X
X

X17
X27
X37
X47
X57
X67

• Provide an opening for making splices
and taps in conductors
• Connect conduit sections
• Provide taps for branch conduit runs
• Make 90-degree bends in conduit runs
• Provide access to conductors in a
conduit system for maintenance and
future system changes

3

• All SnapPack product is individually bar
coded to facilitate more efficient
inventory control
• Distributors and end-users need to
stock a single SKU instead of three
separate component numbers – order
the body, cover and gasket with one
catalog number – saving transaction
costs, and making product selection
and merchandising fast and easy
• Form 7 conduit bodies are compact with
a round back design for neat, efficient
installations
• Conduit hubs have tapered threads and
integral bushings for protection of wire
insulation
• Many shapes and trade sizes available
• Sheet-steel wedge nut cover is provided
with integral gasket. The wedge nut
design facilitates installation and
removal. Nuts and screws are held
captive in cover
• Cover screws are stainless steel with a
combination slotted and Phillips head,
for easy installation and superior
corrosion protection

• UL Standard: 514B
• CSA Standard: C22.2 No. 18

3

1

Features:

Certifications and
Compliances:

1

1
3

1
3

1
3

1
3

1F

Applications:

CG
CG
CG
CG
CG
CG

CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG
CG

CG
CG
CG
CG
CG
CG

Form 7 Condulets and covers are available in additional configurations, sizes and
materials. For a complete listing of Form 7, Form 8 and Mark 9 conduit bodies and
covers see pages 6–12.

Standard Materials:
• Body – Feraloy® iron alloy
• Gasket – urethane
• Cover – sheet steel
• Cover screws – stainless steel

Standard Finishes:
• Feraloy – electrogalvanized with
aluminum acrylic paint
• Sheet steel – electrogalvanized

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

9

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

1F

Dimensions (In Inches)

C

Form 7 C
Size
a
b
c
d
e

1

3

/4

1

11/4

11/2

2

21/2

3

53/8
13/8
13/8
15
/16
33/16

/2

6
15/8
19/16
11/8
313/16

7
17/8
13/4
13/8
41/2

77/16
25/16
23/16
13/4
5

83/16
29/16
27/16
115/16
57/16

93/16
31/8
3
27/16
63/8

12
35/8
41/4
39/16
83/8

113/4
43/8
41/4
39/16
83/8

Form 8 C
Size

1

3

/4

1

11/4

11/2

2

21/2

3

a
b
c
d
e

511/16
17/16
13/8
1
35/16

/2

69/32
111/16
13/16
13/16
315/16

75/16
115/16
13/4
13/8
49/16

81/2
23/8
23/16
13/4
55/16

103/8
225/32
23/4
21/8
61/2

121/4
39/16
33/4
3
89/16

155/8
47/16
5
41/4
107/8

155/8
413/16
5
41/4
107/8

Mark 9 C
Size
a
b
c
d
e

1

/2

3

/4

1

11/4

11/2

2

5
13/8
13/8
13/16
35/16

5 /16
15/8
19/16
13/8
315/16

6 /32
17/8
13/4
11/2
49/16

7 /2
21/2
23/16
115/16
55/16

8 /4
23/4
21/2
21/4
6

10 /2
37/16
33/16
27/8
81/16

11

19

1

1

1

21/2

3

15 /8
47/16
5
41/4
107/8

15 /8
413/16
5
41/4
107/8

5

5

183/4
515/16
61/4
57/16
137/16

Form 7 L

Form 7 E

10

4

183/4
511/16
61/4
57/16
137/16

L

E

Size
a
b
c
d
e

31/2

/2

1

4 /16
13/8
13/8
15
/16
33/16
9

www.crouse-hinds.com

/4

3

5 /16
15/8
19/16
11/8
313/16
3

US: 1-866-764-5454

1
6
17/8
13/4
13/8
41/2

CAN: 1-800-265-0502

Size
a
b
c
d
e

/2

1

4 /16
13/8
21/4
15
/16
33/16
9

/4

1

11/4

11/2

2

5 /16
15/8
27/16
11/8
313/16

6
17/8
23/4
13/8
41/2

6 /2
25/16
33/16
13/4
5

71/8
29/16
39/16
115/16
57/16

31/8
31/8
41/8
27/16
63/8

3

3

Copyright© 2013 Eaton’s Crouse-Hinds Business

1

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

Dimensions (In Inches)
1F

LB

Form 7 LB
Size

1

3

/4

1

11/4

11/2

2

21/2

3

31/2

4

a
b
c
d
e

49/16
21/4
13/8
15
/16
33/16

/2

53/16
21/2
19/16
11/8
313/16

6
27/8
13/4
13/8
41/2

61/2
35/16
23/16
13/4
5

71/8
311/16
27/16
115/16
57/16

81/8
41/4
3
27/16
63/8

101/2
51/8
41/4
39/16
83/8

101/2
57/8
41/4
39/16
83/8

1211/16
69/16
51/4
41/2
101/4

1211/16
71/16
51/4
41/2
101/4

/4

1

11/4

11/2

2

21/2

3

31/2

4

5 /16
27/16
19/16
13/16
315/16

6 /32
213/16
13/4
13/8
49/16

7 /32
311/32
23/16
13/4
55/16

9 /8
41/32
23/4
21/8
61/2

11
413/16
33/4
3
89/16

13 /16
61/8
5
41/4
107/8

13 /16
61/2
5
41/4
107/8

167/8
79/16
61/4
57/16
137/16

167/8
713/16
61/4
57/16
137/16

/4

1

11/4

11/2

2

21/2

3

31/2

4

5 /4
213/32
19/16
13/8
315/16

6 /32
227/32
13/4
11/2
49/16

7 /32
315/32
23/16
115/16
55/16

7 /4
33/4
21/2
21/4
6

10 /32
415/32
33/16
27/8
81/16

13 /16
61/8
5
41/4
107/8

13 /16
61/2
5
41/4
107/8

167/8
79/16
61/4
57/16
137/16

167/8
713/16
61/4
57/16
137/16

Form 8 LB
Size
a
b
c
d
e

/2

1

3

4 /16
27/32
13/8
1
35/16
15

9

15

17

1

15

15

Mark 9 LB
Size
a
b
c
d
e

/2

1

3

4 /32
21/8
13/8
13/16
35/16
19

1

3

1

3

1

15

LL

15

LR

Form 7 LL & LR
Size
a
b
c
d
e

1

3

/4

1

11/4

11/2

2

21/2

3

31/2

4

49/16
13/8
21/4
15
/16
33/16

/2

53/16
15/8
27/16
11/8
313/16

6
17/8
23/4
13/8
41/2

61/2
25/16
33/16
13/4
5

71/8
29/16
39/16
115/16
57/16

81/8
31/8
41/8
27/16
63/8

101/2
35/8
53/4
39/16
83/8

101/2
43/8
53/4
39/16
83/8

1211/16
47/8
615/16
41/2
101/4

1211/16
53/8
615/16
41/2
101/4

Form 8 LL & LR
Size
a
b
c
d
e

1

3

/4

1

11/4

11/2

2

21/2

3

415/16
17/16
25/32
1
35/16

/2

59/16
111/16
25/16
13/16
315/16

615/32
115/16
25/8
13/8
49/16

717/32
23/8
35/32
13/4
55/16

91/8
225/32
4
21/8
61/2

11
39/16
5
3
89/16

1315/16
47/16
611/16
41/4
107/8

1315/16
413/16
611/16
41/4
107/8

Mark 9 LL & LR
Size
a
b
c
d
e

/2

1

4 /32
13/8
21/8
13/16
35/16
19

/4

1

11/4

11/2

2

5 /4
15/8
23/8
13/8
315/16

6 /32
17/8
25/8
11/2
49/16

7 /32
21/2
33/32
115/16
55/16

7 /4
23/4
37/16
21/4
6

10 /32
37/16
41/8
27/8
81/16

3

1

3

1

www.crouse-hinds.com

3

US: 1-866-764-5454

1

CAN: 1-800-265-0502

21/2

3

13 /16
47/16
611/16
41/4
107/8

13 /16
413/16
611/16
41/4
107/8

15

15

31/2

4

167/8
511/16
81/8
57/16
137/16

167/8
515/16
81/8
57/16
137/16

Copyright© 2013 Eaton’s Crouse-Hinds Business

11

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

1F

Dimensions (In Inches)

TB

Form 7TB

T

Form 7T
Size
1
/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

a

b

c

d

e

55/8
61/4
71/4
77/16
83/16
93/16
12
121/16
145/16
145/16

13/4
2
21/4
25/16
29/16
31/8
35/8
43/8
47/8
53/8

27/16
25/8
3
33/16
39/16
41/8
53/4
53/4
615/16
615/16

15

/16
11/8
13/8
13/4
115/16
27/16
39/16
39/16
41/2
41/2

33/16
313/16
41/2
5
57/16
63/8
83/8
83/8
101/4
101/4

511/16
69/32
75/16
81/2
103/8
121/4
155/8
155/8

13/4
2
21/4
25/8
225/32
39/16
47/16
413/16

1
13/16
13/8
13/4
21/8
3
41/4
41/4

35/16
315/16
49/16
55/16
61/2
89/16
107/8
107/8

Form 8T
/2
/4
1
11/4
11/2
2
21/2
3
1

3

25/32
25/16
25/8
35/32
4
5
611/16
611/16

Size
1
/2
3
/4
1
11/4
11/2
2

a

b

c

d

e

55/8
61/4
71/4
77/16
83/16

25/8
27/8
31/4
35/16
5

19/16
13/4
2
23/16
27/16

15

/16
11/8
13/8
13/4
115/16

33/16
313/16
41/2
5
57/16

93/16

61/8

3

27/16

63/8

Form 8TB
/2
/4
1
11/4
11/2
2
1

3

511/16
69/32
75/16
81/2
103/8
121/4

217/32
23/4
31/8
311/32
41/32
413/16

13/8
19/16
13/4
23/16
23/4
33/4

1
13/16
13/8
13/4
21/8
3

35/16
315/16
49/16
55/16
61/2
89/16

13/16
13/8
11/2
115/16
25/32
213/16

35/16
315/16
49/16
55/16
57/8
83/32

Mark 9TB
/2
/4
1
11/4
11/2
2
1

3

5
511/16
619/32
71/2
811/32
105/8

21/8
213/32
227/32
315/32
37/8
419/32

13/8
19/16
13/4
23/16
21/2
37/32

Mark 9T
/2
/4
1
11/4
11/2
2
21/2
3
31/2
4
1

3

5
511/16
619/32
71/2
81/4
101/2
155/8
155/8
183/4
183/4

13/8
/8
17/8
21/2
23/4
37/16
47/16
413/16
511/16
515/16

15

21/8
23/8
25/8
33/32
37/16
41/8
611/16
611/16
81/8
81/8

13/16
13/8
11/2
115/16
21/4
27/8
41/4
41/4
57/16
57/16

35/16
315/16
49/16
55/16
6
81/16
107/8
107/8
137/16
137/16

X

Form 7X
Size
1
/2
3
/4
1
11/4
11/2
2

a

b

c

d

e

55/8
61/4
71/4
77/16
83/16
93/16

35/16
31/2
4
41/8
45/8
53/16

13/4
2
21/4
25/16
29/16
31/8

15

/16
11/8
13/8
13/4
115/16
27/16

33/16
313/16
41/2
5
57/16
63/8

511/16
69/32
75/16
81/2
103/8
121/4

229/32
31/16
31/2
41/8
51/4
61/4

Form 8X
/2
/4
1
11/4
11/2
2
1

3

TA

Form 7TA
Size
1
/2
3
/4
1
11/4
11/2
2

a

b

c

d

e

55/8
61/4
71/4
77/16
83/16
93/16

25/8
27/8
31/4
35/16
311/16
41/4

27/16
25/8
3
33/16
39/16
41/8

15

/16
11/8
13/8
13/4
115/16
27/16

33/16
313/16
41/2
5
57/16
63/8

12

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

13/4
2
21/4
25/8
215/32
39/16

1
13/16
13/8
13/4
21/8
3

35/16
315/16
49/16
55/16
61/2
89/16

Mark 9X
/2
/4
1
1

3

511/16
69/32
75/16

229/32
31/16
31/2

Copyright© 2013 Eaton’s Crouse-Hinds Business

13/4
2
21/4

1
13/16
13/8

35/16
315/16
49/16

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

Mogul Bodies, Covers and Gaskets
BC

Mogul bodies are installed in conduit
systems to:
• Act as pull outlets for conductors that
are stiff, due to large
size or type of insulation
• Provide the longer openings needed
when pulling large conductors
• Prevent sharp bends and kinks in large
conductors (protects insulation during
installation)
• Provide ample openings for splices and
taps
• Provide access to wiring for
maintenance and future
system changes

BLB†

Mogul Series
Size

Cat. #

1
11/4
11/2
2
21/2
3
31/2
4

BC3
BC4
BC5
BC6
BC7
BC8
BC9
BC10

Mogul Series

Features:
Mogul bodies have:
• Long openings
• Provision for easy bends
• Taper tapped hubs with integral
bushings
• Stainless steel cover screws
• Covers are designed with integral gasket

1F

Applications:

Size

Cat. #

1
11/4
11/2
2
21/2
3
31/2
4

BLB3
BLB4
BLB5
BLB6
BLB7
BLB8
BLB9
BLB10

† For 5" size use LBD012.
For 6" size use LBD014.

Dimensions
In Inches:

Certifications and
Compliances:
• UL Standard: 514B
• Fed. Spec.: W-C-586d
• CSA Standard: C22.2 No. 18

Standard Materials:
• Feraloy® iron alloy
BC

Standard Finishes:

Mogul Series BC

• Feraloy – electrogalvanized and
aluminum acrylic paint

Options:
Description
Material – copper-free aluminum
Hot dipped galvanized

BLB

Suffix
SA
HDG

Size
a
b
c
d
e

1

11/4

11/2

2

21/2

3

31/2

4

99/16
17/8
23/16
17/8
6

99/16
25/16
23/16
17/8
6

133/4
29/16
3
25/8
10

133/4
31/8
3
25/8
10

183/8
35/8
41/4
313/16
15

183/8
43/8
41/4
313/16
15

233/4
47/8
51/4
43/4
20

233/4
53/8
51/4
43/4
20

Mogul Series BLB
Size

1

11/4

11/2

2

21/2

3

31/2

4

a
b
c
d
e

819/32
227/32
23/16
17/8
6

819/32
39/32
23/16
17/8
6

1211/16
35/8
3
25/8
10

1211/16
43/16
3
25/8
10

1629/32
53/32
41/4
313/16
15

1629/32
527/32
41/4
313/16
15

221/8
61/2
51/4
43/4
20

221/8
7
51/4
43/4
20

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

13

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

1F

Mogul Bodies, Covers and Gaskets
BUB

BT

Blank Covers

Mogul Series

Mogul Series

Feraloy® iron alloy (for all
Mogul Series except BUBXL)

Size

Cat. #

Size

Cat. #

1
11/4
11/2
2
21/2
3
31/2
4

BUB3
BUB4
BUB5
BUB6
BUB7
BUB8
BUB9
BUB10

1
11/4
11/2
2
21/2
3
31/2
4

BT3
BT4
BT5
BT6
BT7
BT8
BT9
BT10

BUBXL with Cover & Gasket

Size

With Round Neoprene
Gasket Cat. #

1 or 11/4
11/2 or 2
21/2 or 3
31/2 or 4

BG48
BG68
BG88
BG98

BUBXL Moguls
XL Mogul Conduit Bodies and Covers are designed to ease installation, saving time and
money while maintaining the quality you have come to expect from Eaton's Crouse-Hinds.
• Larger internal volume provides additional space for bending and pulling large conductors
(complies with the 6x wire bending rule)
• Rollers improve the ability to pull larger conductors and protect the insulation when the
wire is being pulled, greatly reducing cut cable incidents
• Cover design takes less time to install and can be used as a solid or with the center
removed for more internal volume

Extra Large Mogul Series
Size

Cat. #

2
3

BUBXL6
BUBXL8

Dimensions
In Inches:

B
A
E
C
BUB

BUBXL

BT

Mogul Series BUBXL

Mogul Series BUB
Size
a
b
c
d
e

1

11/4

11/2

2

21/2

3

31/2

4

93/16
211/16
23/16
17/8
6

95/16
33/16
23/16
17/8
6

131/2
31/2
3
25/8
10

131/2
41/8
3
25/8
10

173/4
413/16
41/4
313/16
15

177/8
55/8
41/4
313/16
15

233/8
63/8
51/4
43/4
20

231/4
613/16
51/4
43/4
20

Size
a
b
c
d
e

Mogul Series BT
Size

1

11/4

11/2

2

21/2

3

31/2

4

a
b
c
d
e

99/16
17/8
35/32
17/8
6

99/16
25/16
35/32
17/8
6

133/4
29/16
41/16
25/8
10

133/4
31/8
41/16
25/8
10

183/8
35/8
519/32
313/16
15

183/8
43/8
523/32
313/16
15

233/4
47/8
67/8
43/4
20

233/4
53/8
67/8
43/4
20

14

D

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

2

3

15.28
4.07
3.00
2.25
12.25

22.85
5.58
4.25
3.38
15.25

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

LBD Mogul
1F

Ordering Information

Applications:
LBD bodies are installed at 90° bends in
rigid conduit to:
• Act as pull outlets for conductors that
are stiff due to large size or type of
insulation
• Make 90° bends in conduit system,
allowing straight pull in either direction

/2 – 1"

11/4 – 2", 5" – 6"

1

21/2 – 4"

• Provide for conduit service entrance to
buildings

Size

Cat. #

Size

Cat. #

Size

Cat. #

• Provide for conductor entrance to
motors

/2
3
/4
1

LBD1100
LBD2200
LBD3300

11/4
11/2
2
21/2
3

LBD4400
LBD5500
LBD6600
LBD7700
LBD8800

31/2
4
5
6

LBD9900
LBD10900
LBD012
LBD014

1

• Provide access to wiring for
maintenance and future expansion

Replacement Gaskets for Above Sizes

Features:

Rubber

LBD bodies have:

Size

Cat. #

Size

Cat. #

Size

Cat. #

• Cover openings on an angle permitting
conductors to be pulled straight through
hubs from either direction

/2
3
/4
1

GASK680R
GASK681R
GASK682R

11/4
11/2
2
21/2
3

GASK683R
GASK684R
GASK684R
GASK990R
GASK990R

31/2
4
5
6

GASK989R
GASK989R
GASK687R
GASK688R

1

• Domed covers to permit easy conductor
bends (relieves strain on insulation)
• Cover and gasket furnished

Replacement Cover Assembly with Hardware

• Taper tapped hubs with integral
bushings

Size

Cat. #

Size

Cat. #

Size

Cat. #

/2
3
/4
1

LBD100
LBD200
LBD300

11/4
11/2
2
21/2

LBD400
LBD600
LBD600
LBD800

3
31/2
4
5
6

LBD800
LBD900
LBD900
LBD120
LBD140

1

Certifications and
Compliances:
• UL Standard: 514B

Dimensions

• Fed. Spec.: W-C-586d

In Inches:

• CSA 22.2 No. 18

Standard Materials:
• Body and cover – Feraloy® iron alloy
• Gasket – Neoprene

Standard Finishes:
• Feraloy iron alloy:
1
/2" to 4" sizes, electrogalvanized and
aluminum acrylic paint; 5" and 6" sizes,
zinc chromate primer and aluminum
lacquer
• Neoprene – natural

Options:
Description
Material – All sizes, copper-free
aluminum

Suffix
SA

Cat. #

Size

a

b

c

d

e

LBD1100
LBD2200
LBD3300
LBD4400
LBD5500
LBD6600
LBD7700
LBD8800
LBD9900 (iron)
LBD10900 (iron)
LBD9900 (-SA)
LBD10900 (-SA)
LBD012
LBD014

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4
31/2
4
5
6

5
61/4
61/4
85/8
127/16
127/16
1911/16
1911/16
207/8
207/8
2713/16
2713/16
327/16
411/2

25/16
25/8
215/16
41/4
57/16
57/16
99/16
99/16
107/8
107/8
117/8
117/8
121/2
15

15/16
19/16
113/16
31/2
45/8
45/8
55/8
55/8
73/4
73/4
71/8
71/8
85/8
93/4

1
11/4
11/2
113/16
25/8
25/8
3
3
43/4
43/4
4
4
57/8
7

311/32
417/32
411/32
73/16
107/8
107/8
153/4
153/4
197/8
197/8
24
24
30
39

www.crouse-hinds.com

US: 1-866-764-5454

1

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

15

Condulet® Conduit Bodies Cast Iron or Aluminum

1F

Weather Resistant

1F

Mogul Pulling Elbows
Applications:
Die cast mogul pulling elbows are installed
in conduit systems to provide:

LBNEC Furnished With Cover, Gasket
and Screws

• An accessible weather resistant
chamber for containing heavy duty
conductors
• A chamber for containing 90° turn in
large stiff conductors. Used either to
change conductor direction or to enter
buildings
• A pull box for pulling large conductors
• A chamber for making splices and taps

Size

Cat. #

Bending Radius

• An accessible opening to accommodate
future changes of the system

21/2
3
31/2
4

LBNEC7
LBNEC8
LBNEC9
LBNEC10

51/4
53/4
7
73/8

Features:
• Large dome cover permits easy, straight
through pull

Dimensions
In Inches:

• Dimension from centerline of back hub
to bushing of end hub exceeds six times
the trade diameter of the conduit
• Tapered threads provide easy assembly,
tight construction
• Heavy duty machine screws for cover
• Cover is gasketed
• Smooth design and finish make handling
easy and complement any construction
job

Certifications and
Compliances:
• UL Standard: 514A

Cat. #

Size

a

b

c

LBNEC7
LBNEC8
LBNEC9
LBNEC10

21/2
3
31/2
4

2111/16
2111/16
2811/16
2811/16

89/32
89/32
97/32
97/32

41/2
41/2
51/2
51/2

• NEC: Article 314
• CSA C22.2 No. 18
• CEC: 22.1

Standard Materials:
• Die cast copper-free aluminum

Standard Finishes:
• Aluminum lacquer

16

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Outlet Bodies,
Covers and Gaskets - Stainless Steel

1F

1F

Eaton's Crouse-Hinds Condulet® Stainless Steel Fittings deliver
power where you need it, saving you time and money throughout
the life of your facility.
Superior resistance to corrosion and heat, combined with unmatched
strength, make stainless steel Condulet bodies and boxes a longterm solution for even the most extreme environments.

Applications:
Conduit outlet bodies are installed in conduit systems to:
• Act as pull outlets for conductors being installed
• Provide openings for making splices and taps in conductors
• Act as mounting outlets for lighting fixtures and wiring devices
• Connect conduit sections
• Provide taps for branch conduit runs
• Make 90° bends in conduit runs
• Provide for access to conductors for maintenance and future
system changes

Features:
• Self-healing properties of stainless steel fittings help reduce the
penetration of rust/corrosion and eliminate damage to the fitting
• Stainless steel fittings retain their strength in extreme heat and
extreme cold conditions
• Fitting surface is easy to maintain and keep clean
• Easy cleaning capabilities make these fittings perfect for food
processing and other hygienic areas where wash downs are
common
• Superior strength and durability greatly reduce replacement of
fittings - this will lower your total cost of ownership and increase
your return on investment
• Stainless steel fittings do not require harsh environment-damaging
cleaners to keep them looking like new
• Conduit hubs have tapered threads and feature integral bushing
for protection of wire insulation
• Outlet bodies designed to match conduit size for neat, compact
installations

Dimension
A
B
C
D
E

Overall length
Overall height
Overall width
Width of opening
Length of opening

Certifications and Compliances:
• UL Standard 514A
• CSA Standard C22.2 No. 18.1-04
• Raintight - when installed with cover and gasket

Standard Materials:
•
•
•
•

Bodies - 316 stainless steel
Covers - 316 stainless steel
Cover Screws - 316 stainless steel
Gasket - neoprene

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

17

1F

1F

Condulet® Conduit Outlet Bodies,
Covers and Gaskets - Stainless Steel

Ordering Information - conduit body supplied with cover and gasket
T Conduit Body, Cover and Gasket
Catalog
Number
T18SS
T28SS
T38SS
T48SS
T58SS
T68SS
T88SS
T108SS

Trade
Size
1
/ 2"
3
/ 4"
1"
11/ 4"
11/ 2"
2"
3"
4"

A
5.56
6.61
7.53
8.75
9.37
11.50
15.00
18.25

B
1.75
2.00
2.31
2.50
2.75
3.38
4.63
5.44

C
1.31
1.63
1.78
2.25
2.47
3.13
4.34
5.50

D
1.02
1.27
1.42
1.83
2.03
2.50
3.71
4.87

E
3.15
3.92
4.61
5.50
6.12
8.00
10.25
13.00

LB Conduit Body, Cover and Gasket
Catalog
Number

Trade
Size

A

B

C

D

E

LB18SS
LB28SS
LB38SS
LB48SS
LB58SS
LB68SS
LB88SS
LB108SS

1

/ 2"
3
/ 4"
1"
11/ 4"
11/ 2"
2"
3"
4"

4.86
5.75
6.48
7.75
8.38
10.50
13.50
16.63

1.35
1.63
2.00
3.50
2.75
3.38
6.13
7.25

1.31
1.63
1.78
2.25
2.47
3.13
4.34
5.50

1.02
1.27
1.42
1.83
2.03
2.50
3.71
4.87

3.15
3.94
4.55
5.50
6.13
8.00
10.25
13.00

TB Conduit Body, Cover and Gasket
Catalog
Number
TB28SS
TB38SS
TB48SS
TB58SS
TB68SS

Trade Size

A

B

C

D

E

/ 4"
1"
11/ 4"
11/ 2"
2"

6.61
7.53
8.75
9.37
11.50

2.88
3.23
3.50
3.75
4.38

1.63
1.78
2.25
2.47
3.13

1.27
1.42
1.83
2.03
2.50

3.95
4.61
5.50
6.12
8.00

3

C Conduit Body, Cover and Gasket
Catalog
Number

Trade
Size

A

B

C

D

E

C18SS
C28SS
C38SS

1

/ 2"
3
/ 4"
1"

5.56
6.56
7.50

1.38
1.63
2.00

1.31
1.63
1.78

1.02
1.27
1.42

3.15
3.94
4.61

LL Conduit Body, Cover and Gasket
Catalog
Number

Trade
Size

A

B

C

D

E

LL28SS
LL38SS

3

/ 4"
1"

5.72
6.59

1.63
2.00

1.63
1.78

1.27
1.42

3.95
4.61

LR Conduit Body, Cover and Gasket

18

www.crouse-hinds.com

Catalog
Number

Trade Size

A

B

C

D

E

LR28SS
LR38SS

/ 4"
1"

5.72
6.59

1.63
2.00

1.63
1.78

1.27
1.42

3.95
4.61

US: 1-866-764-5454

3

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Outlet Boxes Cast Iron or Aluminum

1F

Covers and Gaskets

VXF and GRF cast outlet boxes are
installed in threaded rigid conduit
systems to:

GRF Blank Cover

1F

VXF Tapped Surface
With Lugs

Applications:

• Act as junction boxes
• Act as pull outlets
• Accept round base wiring devices and
covers intended for use on 4" outlet
boxes (GRF boxes only)
• Act as ceiling or wall mounting for
Vaporgard™ lighting fixtures (VXF boxes)
• Mount enclosed and gasketed lighting
fixtures: Series ARB and VGR; Series
ARB fixture hangers (GRF boxes)

4 Hubs, 3 Plugs
Hub Size

Cat. #

Description

Iron
Cat. #

Aluminum
Cat. #

/2
/4

VXF10
VXF20

Surface

GRF10

GRF110

1
3

Surface With Lugs

GRF Hub Covers

5 Hubs, 4 Plugs
Hub Size

Cat. #

/2
3
/4

VXFT10
VXFT20

1

Features VXF:

Fixture weight to 125 lbs.

GRF Blank Surface
With Lugs

• Compact, shallow design
• Takes GRF covers

Description Size

• Multiple tapped conduit openings and
pipe plugs for versatility

Surface
Surface

• 4 hubs and 3 plugs on VXF10 and
VXF20

/2
/4

1
3

Iron
Cat. #

Aluminum
Cat. #

GRF11
GRF12

GRF11 SA
GRF12 SA

GRF Gasket

• 5 hubs and 4 plugs on VXFT10 and
VXFT20

Inside Depth

Cat. #

Features GRF:

13/8
115/16
31/8

GRF19
GRF29
GRF39

• Surface mounting. Flush mounting can
be obtained by nailing box to concrete
form through mounting lug
• Drilled mounting lugs

GRFX Tapped Surface
With Lugs

Description

Cat. #

Neoprene

GASK643

• Four conduit bosses spaced 90° apart
on sides and one boss on back
• Blank or drilled and tapped bodies (with
4 side bosses tapped and plugged, plus
blank back boss)

4 Hubs, 3 Plugs
Blank Back Boss

Certifications and
Compliances:

Inside
Depth

Size
Tap

Iron
Cat. #

Aluminum
Cat. #

• GRF – Feraloy® iron alloy or copper-free
aluminum

13/8
13/8
21/16
21/16
21/16
31/8
31/8
31/8

/2
/4
1
/2
3
/4
1
1
/2
3
/4
1

GRFX119
GRFX219
GRFX129
GRFX229
GRFX329
GRFX139
GRFX239
GRFX339

GRF119
GRF219
GRF129
GRF229
GRF329
GRF139
GRF239
GRF339

Standard Finishes:

Dimensions

• UL Standard: boxes and covers – 514A
• CSA Standard: C22.2

Standard Materials:
• VXF – copper-free aluminum

1
3

In Inches:

• VXF – epoxy enamel
• GRF – electrogalvanized and aluminum
acrylic paint

Options:
Description
GRF bodies and covers - hot
dipped galvanized

Suffix
HDG
VXF-VXFT†

GRF-GRFX

†VXFT has hubs on 4 sides and back; VXF has hubs on 4 sides only.
See lighting section 7L for complete listing of lighting fixtures and hangers.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

19

Condulet® Service Entrance Elbows and Tees

1F

1F

Applications:

Options:

SLB and LBY elbows are installed in
conduit systems to:
• Act as service entrance elbows between
service entrance and vertical
weatherhead conduit runs
• Make 90° bends in conduit systems
where space is limited
• Act as pull outlets
• Provide access to conductors for
maintenance and future system changes

Description
Finishes – LBY elbows:
Corro-free™ epoxy power coat
Material (LBY only) – copper-free
aluminum construction

ET short radius tees are installed in conduit
systems:
• In concealed conduit runs allowing single
conduit stub up to outlet boxes located
above or below main conduit run.
Eliminates separate feed and return
conduits to flush floor box or junction
box

LBY (includes cover)
Suffix
S752
SA

SLB (includes cover)

Size

Cat. #

/2
3
/4
1
11/4
11/2

LBY15
LBY25
LBY35
LBY45
LBY55

1

Size

Cat. #

/2
3
/4
1
11/4
11/2
2

SLB1
SLB2
SLB3
SLB4
SLB5
SLB6

1

ET

Size

Cat. #

/4 – 1/2 – 1/2
3
/4 – 3/4 – 3/4
1 – 3/4 – 3/4
Largest hub shown at top

ET218
ET228
ET328
of photo

3

Features:
SLB elbows have:
• Compact overall size and short hubs
• Taper tapped hubs and integral bushing
for standard threaded conduit
• Covers and gaskets furnished

Dimensions
In Inches:

LBY elbows have:
• Maximum volume for bends within a
compact overall size
• Screw-on cover for ease of installation
and removal
• Cover openings on an angle, permitting
conductors to be pulled straight through
either hub
• Taper tapped hubs and integral bushing
for standard threaded conduit

LBY

SLB

ET short radius tees have:
• Compact size, small radius of bend for
use in concealed or open conduit
systems. Particularly suited for use in
shallow floors or partitions
• Taper tapped hubs and integral bushing
for standard threaded conduit
ET

Certifications and
Compliances:

SLB

• UL Standard: 514B
• Fed. Spec.: W-C-586a

Standard Materials:
• SLB elbows – copper–free aluminum
• LBY elbows – Feraloy® iron alloy
• ET tees – Feraloy iron alloy

Standard Finishes:
• Copper-free aluminum – natural
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint

20

www.crouse-hinds.com

US: 1-866-764-5454

Size
a
b
c
d
e

1

3

/4

1

13/4

11/2

2

31/8
125/32
13/16
1
211/16

/2

31/2
2
13/8
13/16
215/16

41/8
19
/32
111/16
115/32
311/32

53/8
225/32
23/32
17/8
43/4

623/32
31/32
23/8
25/32
61/32

73/4
329/32
3
25/8
631/32

LBY
Size
a
b

1

3

/4

1

13/4

11/2

213/16
2

/2

33/16
21/4

31/4
21/2

325/32
215/16

41/2
33/8

ET
Size
a
b
c
d

CAN: 1-800-265-0502

3

3

/4 – 3/4 – 3/4

1 – 3/4 – 3/4

4
25/8
11/4
11/2

/4 – 1/2 – 1/2

4
3
11/2
11/2

4
3
11/2
13/4

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Device Boxes
Non-hazardous

2F

Page No.

Application/Selection

see page 22

Shape Selector Charts

see page 23

Device Boxes - Cast Iron or Aluminum
FS/FD Series
Single gang
Blank
Cast hubs
Multi-gang
Blank
Cast hubs

see pages 31–34
see pages 25–28
see pages 31–34
see pages 29–30

Covers for Cast Iron or Aluminum Device Boxes
WLR and WLG Wet Locations Covers For NEMA
Configuration and GFCI Receptacles
Blank
Pilot light
Push button
Receptacle
Switch

see
see
see
see
see

page
page
page
page
page

39
43
41
37
39

Device Boxes and Covers - Stainless Steel
FS/FD Series

see pages 35–36

Plugs and Receptacles
DS Series

see page 42

DS/WP Series

see page 42

FSE Series

see page 46

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

21

2F

Description

Condulet® Cast Device Boxes and Covers

2F

2F

Application and Selection
Applications:

Considerations for Selection of Covers,
Devices, and Accessories

Cast device boxes are installed in conduit and cable systems to:
• Accommodate wiring devices

Both general purpose and weatherproof, waterproof devices and
covers are available. Selection will depend on individual conditions.
To provide for a wide variety of applications, the following covers
and devices are available:

• Act as pull boxes for conductors in a conduit system
• Provide openings to make splices and taps in conductors
• Provide access to conductors for maintenance and future system
changes

Considerations for Selection of Device Box
Type of conduit system:
• Should be compatible with conduit or cable system.
• Boxes are standard with mounting lugs and internal green ground
screw.
• Boxes are available for rigid steel, IMC; rigid aluminum; flexible
conduit and cable systems.
Number of devices to be used in the box:
• Standard flush devices require one gang each
Depth:
• Two box types are available – standard (FS) and deep (FD), single
through five gang.

Covers
General use snap switch
Pushbutton switch
Plug and receptacle
Blank
Pilot light
Receptacle

Pg.
see pages 39–41 and 44–45
see page 41
see pages 37, 39, 42, and 44–46
see pages 39 and 44–45
see page 43
see pages 37–39, 42, and 44–46

Devices
Receptacle
Pilot lights
Wiring device

Pg.
see page 42
see page 43
see page 42

Accessories
Gaskets
Box extensions
Flush mtg. adapter

Pg.
see page 43
see page 43
see page 43

• Standard flush wiring devices will normally fit in the FS boxes.
• Some special purpose devices of higher ratings will require the
deeper box (FD).

Options:

• In addition, the need for additional wiring space will require the
deep box.

Description
Corro-free™ epoxy powder coat

Suffix
S752

Hub configuration and size:
• The layout of the conduit system dictates the conduit opening
locations of the box.
The table below indicates the types of conduit and the boxes
available. Drilled and tapped openings can be supplied in blank
boxes to meet your requirements.
• Hub size is the same as conduit size. A variety of hub sizes are
available. Where the specific hub size is not available, reducing
bushings can be used.
Materials and finishes:
• The environment and the use of the box will determine the material
and finish needed. Areas of the country with harsh weather and
corrosive environments may require different materials and finishes
for added protection.
• Standard material and finish is Feraloy® iron alloy with
electrogalvanized and aluminum acrylic paint. Many items are also
available in copper-free aluminum.
• Optional finishes can be obtained if environment warrants. See
Options listings.

Quick Selector Chart
Box
FS

Depth
111/16

Gang
1-3

Conduit
Type
Threaded rigid

Standard
Material
Feraloy iron alloy
(some are copper-free
aluminum)

Standard
Finish
Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint.
Copper-free aluminum – natural

FD

21/2

1-3

Threaded rigid

Feraloy iron alloy

Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint

FD-SS

3.03

1

Threaded rigid

Stainless steel

Natural

FS blank bodies
Drilled and tapped

115/16

1-4
1-3

Threaded rigid

Feraloy iron alloy

Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint

FD blank bodies
Drilled & tapped

21/2

1-5
1-3

Threaded rigid

Feraloy iron alloy

Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint

22

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Cast Device Boxes with Hubs

2F

Single Gang Shape Selector Chart
Page

FS/FD

see pages 25–26

FS (Double face)

see pages 25–28

FS-SA

see pages 25–26

Series

Page

FSSA

FSL/FDL

Page

see pages 25–26

FSCA
FSR/FDR

Series

2F

Series

FSY (With flange)

see pages 27–28

FSX/FDX

see pages 27–28

FDXC

see pages 27–28

FSCD

see pages 27–28

FD Stainless Steel

see pages 35–36

see pages 25–26

see pages 25–26

FSS

see pages 25–26

FDD

see pages 25–26

see pages 25–26

FSLA/FDLA

see pages 25–26

FSC

see pages 25–26

FDC

see pages 25–26

FSC (Double face)

see pages 25–28

FSC-SA

see pages 25–26

FSCC/FDCC

see pages 25–26

FSA/FDA

see pages 25–26

FSCT/FDCT

see pages 27–28

FST/FDT

see pages 27–28

If the hub configurations required are not available, drilled and tapped openings can be provided in blank boxes per your
specifications. See pages 31–34 for details.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

23

2F

Condulet® Cast Device Boxes with Hubs

2F

Multi-Gang Shape Selector Chart
Series

Page

Series

Page

Series

Page

FSC
(Two gang tandem)

see pages 29–30

FSD (Two gang)

see pages 29–30

FS/FD (Three gang)

see pages 29–30

FS/FD (Two gang)

see pages 29–30

FSS/FDS (Two gang)

see pages 29–30

FSS (Three gang)

see pages 29–30

FSC/FDC (Two gang)

see pages 29–30

FSE (Two gang)

see pages 29–30

If the hub configurations required are not available, drilled and tapped openings can be provided in blank boxes per your
specifications. See pages 31–34 for details.

24

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Single Gang Device Boxes Cast Iron or Aluminum

Accessories
see pages 37–45

2F

With and Without Mounting Lugs for
Threaded Rigid and IMC Conduit
Options:
Description
Finishes:
Corro-free™ epoxy powder coat
- external body
Corro-free™ epoxy powder coat
- internal and external
Hot dipped galvanized

2F

Applications:
Cast device boxes are installed to:
• Accommodate wiring devices
• Act as pull boxes for conductors in a
conduit system
• Provide openings to make splices and
taps in conductors
• Provide access to conductors for
maintenance and future system changes
• Connect conduit sections
• FSY boxes for mounting surface devices
on floor or bench (used with single gang
covers)

Suffix

S752
S753
HDG

Size Ranges:
• Hubs – 1/ 2" to 1"

Die Cast Aluminum‡

FS & FD

Features:
• Internal green ground screw standard on
boxes
• Suitable for use in wet locations when
used with gasketed covers
• Mounting lugs standard on most boxes
• Tapered threaded hubs (NPT) with
integral bushing
• Available for surface mounting (with
mounting lugs) or flush mounting
(without mounting lugs) as listed
• Available as shallow (FS) or deep (FD)
configuration. Use FD if device to be
enclosed exceeds 15/ 8" in depth
• Ample wiring room provided in either FS
or FD configuration
• Wide selection of surface or flush covers
available in three materials (sheet steel,
Feraloy®, aluminum)
• Covers for flush mounting extend to
conceal the rough plaster line
• Available in single gang and multi-gang
configurations with hubs, and as blank
bodies for drilled and tapped openings

Certifications and
Compliances:
•
•
•
•

UL Standard: 514
ANSI Standard: C33.84
Fed. Spec.: W-C-5860
CSA Standard: C22.2 No. 18

Size

Cat. #

Cat. #

/2
3
/4

FS1 SA
FS2 SA

FSC1 SA
FSC2 SA

1

Size

Cat. #

Cat. #

/2
3
/4
1

FS1*
FS2*
FS3†

FD1†
FD2†
FD3†

1

Size

Cat. #

Cat. #

1

/2
3
/4

FSR1
FSR2

FDR1
FDR2*†

Size

Cat. #

Cat. #

1

/2
3
/4
1

FSC1*
FSC2*
FSC3†

FDC1†
FDC2†
FDC3†

Size

Cat. #

Cat. #

/2
3
/4

FSL1
FSL2

FDL1
FDL2*†

‡Mounting lugs and ground screw are not offered with
standard die cast aluminum box. For sand cast
aluminum box with mounting lugs and ground screw,
change "SA" in catalog number to "SCA"
(Example: FS1 SCA).

Standard Materials:
• Feraloy iron alloy or copper-free
aluminum.

Standard Finishes:
• Feraloy – electrogalvanized and
aluminum acrylic paint
• Aluminum – natural

1

*Available in sand cast copper-free aluminum – add
suffix SCA to Cat. No.
†Available in sand cast copper-free aluminum – add
suffix SA to Cat. No.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

25

2F

Condulet® Single Gang Device Boxes Cast Iron or Aluminum

Accessories
see pages 37–45

2F

With and Without Mounting Lugs for
Threaded Rigid and IMC Conduit
FS & FD

Dimensions
In Inches:

Size

Cat. #†

Cat. #†

1

/2
3
/4

FSA1
FSA2

FDA1
FDA2

Size

Cat. #†

Cat. #†

/2
3
/4
1

FSS1*
FSS2*
FSS3

FDD1
FDD2*
FDD3

1

Series
FS

Hub Size
1
/2
3
/4
1

a

b

c

d

/8
7
/8
1

17/8
17/8
17/8

111/16
111/16
111/16

5

/2
/4
1

/8
/8
1

211/16
211/16
211/16

21/2
21/2
21/2

5

1

Size

Cat. #

Cat. #

/2
3
/4

FSCC1
FSCC2

FDCC1
FDCC2

1

Size

Cat. #

/2
3
/4

FSCA1
FSCA2

Size

Cat. #†

/4

FSSA2

1

3

Size

Cat. #

Cat. #

/2
3
/4

FSLA1
FSLA2

FDLA1
FDLA2

1

FD

3

7

7
7

*Available in copper-free aluminum; add suffix "SA".
†Mounting lugs not available.

26

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

/8
/4
/8

3
7

/8
/4
7
/8
3

Condulet® Single Gang Device Boxes Cast Iron or Aluminum

2F

Accessories
see pages 37–45

With and Without Mounting Lugs for
Threaded Rigid and IMC Conduit
FDXC†

FSY

2F

FS & FD

Size

Cat. #

Cat. #

Hub Size

Cat. #‡

/2
3
/4
1

FSCT1
FSCT2*
FSCT3

FDCT1
FDCT2*
FDCT3

3

/4

FDXC219

1

Description

Hub Size

Cat. # ‡

Single face
Double face

1
1

FSY311
FSY312

Dimensions
In Inches:

Size

Cat. #

Cat. #

/2
3
/4
1

FST1*
FST2*

FDT1
FDT2
FDT3

1

FSCT, FSX, FST, FSCD

Size

Cat. #

Cat. #

/2
3
/4
1

FSX1
FSX2

FDX1
FDX2
FDX3

1

Size

Cat. #‡

/2
3
/4

FSCD1
FSCD2

1

*Available in copper-free aluminum; add suffix "SA".
†6 Hubs – all 3/ 4" pipe tap.
‡ Not avaliable with mounting lugs.

FSY

FDXC

FSCT, FSX, FST, FSCD
Series
FS

Hub Size

a

b

c

d

/2
3
/4
1

7

/8
7
/8
1

17/8
17/8
17/8

111/16
111/16
111/16

5

1

/8
/4
/8

3
7

FSY
Description

Hub Size

a

b

Single gang, single face

1

23/4

115/16

Single gang, double face

1

23/4

33/8

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

27

2F

Condulet® Single Gang Device Boxes Cast Iron or Aluminum

Accessories
see pages 37–45

2F

With and Without Mounting Lugs
FS

Double Face

Double Face
Size

Cat. #†

Size

Cat. #†

/2
3
/4

FS152
FS252

1

/2
3
/4

FSC152
FSC252

1

†Mounting lugs not available.

Dimensions
In Inches:

Double face
Series
FS

28

Hub Size

a

b

c

/2
3
/4

35/16
311/16

31/8
31/2

11/4
11/2

1

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Multi-Gang Device Boxes Cast Iron or Aluminum

Accessories
see pages 37–45

2F

With and Without Mounting Lugs for
Threaded Rigid and IMC Conduit
2F

FSE

FSC†

FS†

Two Gang
Size

Cat. #

/4

FSE22

3

Two Gang Tandem

Two Gang Tandem

Size

Cat. #

Size

Cat. #

/2
3
/4

FS17
FS27

1

/2
3
/4

FSC17
FSC27

1

FS & FD

Dimensions
In Inches:

Two Gang
Size

Cat. #

Cat. #

/2
3
/4
1

FS12*
FS22*
FS32

FD12
FD22*
FD32

1

FSC & FDC

Two gang tandem

Two gang

Two gang tandem
Hub
Size

Series
FS

/2
3
/4

1

a

b

e

/8
7
/8

5

/8
3
/4

11/4
11/2

7

Two gang
Two Gang
Size

Cat. #

Cat. #

/2
/4
1

FSC12
FSC222
FSC32

FDC12
FDC222*
FDC32

1
3

Series

Hub Size

a

b

c

d

h

FS

1

/2
3
/4
1

/8
7
/8
1

21/4
21/4
21/2

17/8
17/8
17/8

111/16
111/16
111/16

5

/2
/4
1

/8
/8
1

21/4
21/4
21/2

211/16
211/16
211/16

21/2
21/2
21/2

5

1

FD

†Use single gang covers only.

3

7

7
7

/8
/4
/8

3
7

/8
/4
/8

3
7

*Available in copper-free aluminum;
add suffix "SA".

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

29

2F

Condulet® Multi-Gang Device Boxes Cast Iron or Aluminum

Accessories
see pages 37–45

2F

With and Without Mounting Lugs for
Threaded Rigid and IMC Conduit
FSS & FDS

FSD

Two Gang

Two Gang

Size

Cat. #

Cat. #

Size

Cat. #

/4

FSS222

FDS222

3

/4

FSD212*

3

*Hubs on 2 hub side are 1/2"

FS & FD

FSS

Three Gang

Three Gang
Size
/4
1

3

Cat. #
FS23
FS33

Cat. #

Size

Cat. #

FD23

3

/4

FSS23

Dimensions
In Inches:

Three gang
Series
FS
Two gang with mounting lugs

30

www.crouse-hinds.com

US: 1-866-764-5454

Three gang

CAN: 1-800-265-0502

FD

Copyright© 2013 Eaton’s Crouse-Hinds Business

Hub
Size

a

c

d

/4
1

/8
1

17/8
17/8

111/16
111/16

/8

211/16

21/2

3

/4

3

7

7

Accessories
see pages 37–45

Condulet® Blank Device Boxes - Cast Iron

2F

Blank Bodies With Mounting Lugs for
Drilling and Tapping Single Gang,
Multi-Gang, Tandem
2F

Applications:
Blank cast device boxes are used:
• Where several wiring devices are to be
grouped together
FS062, FD062 two gang

• To assemble special combinations of
wiring devices
• Where special arrangements of conduit
hubs or entrances are required

FS019, FD019 single gang

Features:
• Available in shallow (FS) or deep (FD)
configurations.

FS063, FD063 three gang

• FS/FD bodies have thick walls for drilling
and tapping conduit entrances.
• Internal green ground screw standard on
boxes.
• Available in single, two, three, four and
five gang and two gang tandem bodies.

FS094, FD094 four gang
FS029, FD029 two gang

• Cast mounting lugs at diagonally
opposite corners.
• For a wide selection of standard surface
or flush covers see pages 37–45.

Certifications and
Compliances:
• UL Standard: 514A
• CSA Standard: C22.2 No. 18

FS039, FD039 three gang

Standard Materials:

FS097, FD097 two gang tandem

• Feraloy iron alloy

Ordering Information:

Standard Finishes:
• Feraloy – electrogalvanized and
aluminum acrylic paint
FD04 four gang

FD05 five gang

Description

Shallow Deep
Cat. #
Cat. #

Single gang

FS019

FD019*

Two gang

FS029

FD029*

Three gang

FS039

FD039*

Four gang

FD04

Five gang

FD05

Two gang (takes one
two gang cover)

FS062

FD062

Three gang (takes one
three gang cover)

FS063

FD063

Four gang (takes one
four gang cover)

FS094

FD094

Two gang tandem

FS097

FD097

*Available in copper-free aluminum. To order add suffix
SA to Cat. No.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

31

2F

Condulet® Blank Device Boxes - Cast Iron

2F

Blank Bodies for Drilling and Tapping
Ordering Information
Ordering Information:

Table 1/Drilling and Tapping Arrangements*

To order one of the blank bodies with
drilled and tapped holes listed on see
pages 31–33, proceed as follows:
Step 1
Select the required box.
Step 2
Select the arrangement that meets the
requirements from Table 1.
Step 3
Determine the maximum size and spacing
of conduit openings from Table 2.
Step 4
Substitute the appropriate symbol from
Table 4 for each conduit entrance, using
‘‘0’’ (zero) for those locations on
arrangement where an entrance is not
required.
Example:
Step 1 – box required FS062
Step 2 – arrangement 1
Step 3 – conduit entrances – 1/2" at "a",
none at "b"; 1" at "c" and "d"; none at "e"
and "f".
Step 4 – symbols are substituted and
written in alphabetical order starting with
location "a". For this example A0CC00.

Two, Three, Four and Five Gang

1

2†

4†

5

*Drilling and tapping arrangements other than those in Table 1 are available. Consult Eaton's Crouse-Hinds.
†If only one conduit entry is specified or permitted (see Table 2) on a side wall that conduit entry will be centered on the wall.

Single Gang Only (FS or FD019)

Complete Cat. No. is made up of
three parts:
Part 1 – box number;
Part 2 – arrangement number;
Part 3 – symbols for conduit entrances.
For this example:
FS062-1-A0CC00.

Two Gang Tandem (FS or FD097)

32

www.crouse-hinds.com

US: 1-866-764-5454

3†

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

2F

Condulet® Cast Device Boxes
Blank Bodies for Drilling and Tapping
Single-Gang, Multi-Gang, Tandem

2F

Table 2/Maximum Number, Size and Spacing of Conduit Openings
Cat. #

Maximum Conduit Opening Size
Top and Bottom
1
2
3
4
5

Sides
1

FS019
FD019*
FS029
FD029*
FS039
FD039*
FD04
FD05
FS062
FD062
FS063
FD063
FS094
FD094
FS097
FD097

1
11/2
1
11/2
1
11/2
11/2
11/2
1
11/2
1
11/2
1
11/2
1
11/2

1
11/2
1
11/2
1
11/2
11/2
11/2
1
11/2
1
11/2
1
11/2
1
11/2

1
11/2
1
11/2
11/2
11/2
1
11/4
1
11/4
1
11/2
11/2
11/2

1
1
1
11/2
11/2
11/2
3
/4
3
/4
1
1
1
11/2

/4
/4
1
11/2
11/2
11/2
3
3

/4
/4
1
1

1
1
11/2

3
3

/4
/4

3
3

2

1
1
1
1
1
1
1
1
1
11/2

Table 3/Distance From Mounting Surface
to Centerline of Conduit Opening ("u")
Cat. #

u

FS019
FD019*
FS029
FD029*
FS039
FD039*
FD04
FD05
FS062
FD062
FS063
FD063
FS094
FD094
FS097
FD097

29

/32
13/8
29
/32
13/8
31
/32
13/8
19/16
19/16
15/32
15/8
15/32
15/8
15/32
19/16
15/32
19/16

Back
2

1
1
1
11/4
1
11/4
1
1
11/2
11/2

Spacings
s
v

1
1

13/16
13/16
11/4
1
11/4
1
11/4
11/8
15/16
15/16

w

x

y

z

17/8
17/8
33/4
33/4
17/8
33/4
29
/32
1
113/16
113/16
113/16
11/2
3
/4
3
/4

17/8
17/8
33/4
33/4
33/4
33/4
15/8
13/8
113/16
2
113/16
25/8

15/16
15/16
21/2
21/2
33/4
33/4

17/8
17/8

15/8
17/16
113/16
113/16

33/4

15/8
15/8

Table 4/Symbols for Openings
Conduit Size
1
/2
3
/4
1
11/4
11/2
None

Symbol
A
B
C
E
F
0

*Available in copper-free aluminum. To order add suffix SA to Cat. No.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

33

Condulet® Cast Device Boxes

2F

2F

Blank Bodies for Drilling and Tapping
Single-Gang, Multi-Gang, Tandem
Dimensions (In Inches)

Cat. #

a

b

FS/FD019
FS/FD029
FS/FD039
FD04
FD05

31/4
7
103/4
143/8
181/8

31/4
7
103/4
15
183/4

FS/FD094

FS/FD062
Cat. #

a

b

FS062
FD062

27/8
215/16

53/4 5
57/8 51/16

Cat. #

a

FS/FD063
b
c
d

e

FS063
FD063

313/16
37/8

75/8 67/8
71/4 71/16

11/2 61/4
21/2 63/16

34

c

d

e

23/16
31/16

11/2 43/8
21/2 45/16

23/16
31/32

www.crouse-hinds.com

f

Cat. #

a

b

FS094
FD094

23/16
3

145/64
21/2

Cat. #

a

b

FS097
FD097

21/32
227/32

11/2
25/16

FS/FD097
f

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

2F

Condulet® Stainless Steel Conduit
Device Boxes, Covers and Gaskets

2F

Eaton's Crouse-Hinds Condulet® Stainless Steel Device Boxes
deliver power where you need it, saving you time and money
throughout the life of your facility.
Superior resistance to corrosion and heat, combined with unmatched
strength, make stainless steel Condulet bodies and boxes a longterm solution for even the most extreme environments.

Applications:
Cast device boxes are installed in conduit systems to:
• Accommodate wiring devices
• Act as pull boxes for conductors in a conduit system
• Provide openings to make splices and taps in conductors
• Provide access to conductors for maintenance and future
system changes
• Connect conduit systems

Features:
• Self-healing properties of stainless steel fittings help reduce the
penetration of rust/corrosion and eliminate damage to the fitting
• Stainless steel fittings retain their strength in extreme heat and
extreme cold conditions
• Fitting surface is easy to maintain and keep clean
• Easy cleaning capabilities make these fittings perfect for food
processing and other hygienic areas where wash downs are
common
• Superior strength and durability greatly reduce replacement of
fittings - this will lower your total cost of ownership and increase
your return on investment
• Stainless steel fittings do not require harsh environment-damaging
cleaners to keep them looking like new
• Internal green grounding screw - standard
• Tapered threads for protection of wire insulation
• Wide selection of covers available
• Single or double conduit entry
• Ample wiring room provided for easy installations

Dimension
A
B
C
D
E
F

Length of box
Overall length (including hubs)
Width of box
Overall width (including hubs)
Height of box
Overall height (including hubs)

Certifications and Compliances:
• UL Standard 514A
• CSA Standard C22.2 No. 18.1-04
• Raintight - when installed with cover and gasket

Standard Materials:
•
•
•
•

Bodies - 316 stainless steel
Covers - 316 stainless steel
Cover Screws - 316 stainless steel
Gasket - neoprene

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

35

2F

Condulet® Stainless Steel Conduit Device Boxes,
Covers and Gaskets

2F

The Ultimate in Corrosion Resistance and Durability
Ordering Information
FD Device Body
Catalog Number

Trade Size

A

B

C

D

E

F

FD2SS

3

/ 4"

4.63

5.41

2.94

2.94

3.03

3.03

FDC Device Body
Catalog Number

Trade Size

A

B

C

D

E

F

FDC2SS

3

/ 4"

4.63

6.19

2.94

2.94

3.03

3.03

FDS Device Body
Catalog Number

Trade Size

A

B

C

D

E

F

FDS2SS

3

/ 4"

4.63

5.41

2.94

2.94

3.03

3.03

FDA Device Body
Catalog Number

Trade Size

A

B

C

D

E

F

FDA2SS

3

/ 4"

4.63

4.63

2.94

2.94

3.03

3.80

FDX Device Body

Catalog Number

Trade Size

A

B

C

D

E

F

FDX2SS

3

/ 4"

4.63

6.19

2.94

4.50

3.03

3.03

Ordering Information - Device Box Cover and Gasket
Blank Cover

Blank Formed Cover
Catalog Number

Catalog Number

DS7000BC

DS7000BF

Receptacle Formed Cover

Switch Formed Cover

36

www.crouse-hinds.com

Catalog Number

Catalog Number

DS7000SF

DS7000RF

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

2F

Covers for Cast Iron or Aluminum Device Boxes
WLRS and WLG Wet Location Covers
For NEMA Configuration Receptacle Interiors and GFCI Receptacles
Standard Materials:

WLRS, WLRD and WLGF series wiring
device covers are designed to meet the
total NEC Code requirements for wet
locations. WLRS, WLRD and WLGF series
covers are suitable for use in wet and
damp locations:
• Wherever portable equipment is required
• As general purpose utility receptacle
covers
• For industrial, commercial or residential
use
• In areas where electrical requirements
do not exceed medium duty ratings
• To mount FS and FD single-gang or
multi-gang boxes having individual cover
openings (see Sect. 2F for listings)
• To mount on most flush device boxes
(see Accessories)

• WLRS, WLRD and WLGF face plate and
cover – die cast copper-free aluminum
• Cover hinge spring – stainless steel
• Cover screws – corrosion resistant metal
• Gasket – ethylene propylene rubber
(EPDM)

Features:
WLRS, WLRD and WLGF covers:
• Self-closing spring door assures
protection of wiring device at all times,
in wet and damp locations
• One piece EPDM gasket provides
environmental protection of wiring
device at all times
• EPDM gasketing material offers
excellent resistance to ozone, weather
and temperature extremes of –50°F to
260°F
• Die cast, copper-free aluminum
construction with aluminum lacquer
finish provides maximum corrosion
resistance
• Positive ground path ensured for all
exposed metal parts
NEMA configuration receptacle
interiors:
• Comply with NEMA Standards WD-1
and WD-5
• Grounded through an extra contact in all
types except 3-phase applications; self
grounded in duplex variety
• Back and side wired
• Offered in single and duplex
configurations for use with standard
plugs
• Specification grade

2F

Applications:

Standard Finishes:
• Copper-free aluminum – aluminum
lacquer

Electrical Rating Ranges:
• 15 amperes; 125, 250, or 277 volts
• 20 and 30 amperes; 125, 250, 277, 480,
600, 125 / 250, 208 / 120, 480 / 277 or
600 / 347 volts

Typical installation

Accessories:
• Flush mounting adapter – WLRA-1
required for mounting on device boxes.
(Order separately)

Spring Door Covers – with Gasket*
For NEMA Configuration Round Receptacles

Single cover
Cat. #

Diameter

WLRS1
WLRS2

13/8"
11/2"

Duplex cover
Cat. #

Diameter

WLRD1

13/8"

*Patent Number 4,058,358
†Horizontal mount only.

Spring Door Covers – with Gasket*
For GFCI Receptacles in Wet Locations

Certifications and
Compliances:
•
•
•
•

ANSI/UL Standard 514A
NEC Code 410-57
OSHA Standards, Subpart "S"
NEMA Standards WD-1, 1974 (Straight
Blade) and WD-5, 1972 (Locking Type)

Horizontal Mount
for flush
device boxes
Cat. #

Horizontal Mount
for FS and FD
device boxes
Cat. #

Vertical Mount
for FS and FD
device boxes
Cat. #

WLGF

WLGF FS

WLGF FSV

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

37

Covers for Cast Iron or Aluminum Device Boxes
WLRS and WLG Wet Location Covers

2F

2F

For NEMA Configuration Receptacle Interiors and GFCI Receptacles
Ordering Information - Covers with and
without NEMA Configuration Receptacles

Dimensions
In Inches:

For Non-Locking Blade Plugs
Complete
Cover with
Receptacle
Assy. Cat. #

Spring Door
Cover &
Gasket Only
Cat. #*

5-15R

WLRS 5 15

WLRS1

6-15R

WLRS 6 15

WLRS1

125V

5-20R

WLRS 5 20

WLRS1

250V

6-20R

WLRS 6 20

WLRS1

Complete
Cover with
Receptacle
Assy. Cat. #

Spring Door
Cover &
Gasket Only
Cat. #*

5-15R

WLRD 5 15

WLRD1

6-15R

WLRD 6 15

WLRD1

125V

5-20R

WLRD 5 20

WLRD1

250V

6-20R

WLRD 6 20

WLRD1

Type
Volts
Single Device
2-Pole
125V
3-Wire
Grounding
250V
15 Amp
2-Pole
3-Wire
Grounding
20 Amp

Type
Volts
Duplex Device
2-Pole
125V
3-Wire
Grounding
250V
15 Amp
2-Pole
3-Wire
Grounding
20 Amp

NEMA
Configuration

NEMA
Configuration

WLGF

Ordering Information - Covers with and
without NEMA Configuration Receptacles
For Locking Blade Plugs

Type
Volts
Single Device
2-Pole
125V
3-Wire
Grounding 250V
15 Amp
2-Pole
3-Wire
Grounding
20 Amp

NEMA
Configuration

Complete
Cover with
Receptacle
Assy. Cat. #

Spring Door
Cover &
Gasket Only
Cat. #*
WLGF-FS & WLGF-FSV

L5-15R

WLRS L5 15 WLRS1

L6-15R

WLRS L6 15 WLRS1

125V

L5-20R

WLRS L5 20 WLRS2

250V

L6-20R

WLRS L6 20 WLRS2

Type
Volts
Duplex Device
2-Pole
3-Wire
125V
Grounding
15 Amp

NEMA
Configuration

L5-15R

Complete
Cover with
Receptacle
Assy. Cat. #

Spring Door
Cover &
Gasket Only
Cat. #*

WLRD L5 15 WLRD1

*Must be used with a wet locations rated wiring device.

38

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Covers for Cast Iron or Aluminum Device Boxes

2F

Single Gang
2F

Ordering Information

Blank cover for enclosing splices and
taps where device not used.
Description

Material

Cat. #

Surface
Flush

Sheet aluminum
Sheet steel

DS100
DSS100

For GFI receptacles.
Description

Material

Cat. #

Surface

Sheet steel

DS23 GFI

For square handle general use snap or
toggle switches – unguarded.
Description

Material

Surface
Surface

Sheet steel
DS32
Sheet aluminum DS32 SA

Cat. #

For flush plug receptacle requiring 15/8"
opening diameter.
Blank cover with gasket for enclosing
splices and taps where device not used.
Description

Material

Cat. #

Surface or
Flush

Cast aluminum

DS100G

Description

Material

Cat. #

Surface

Sheet steel

DS35

For square handle general use snap or
toggle switches – guarded.
Description

Material

Cat. #

Surface
or flush

Feraloy®
iron alloy
with gasket

DS32G

Surface

Sheet steel

DS52

For duplex convenience receptacles.

DS21

DS21G

Description

Material

Surface
Surface
Flush

Sheet steel
DS23
Sheet aluminum DS23 SA
Sheet steel
DSS23

Cat. #

For standard and 3-pole, 2-wire
grounding type round flush
receptacles. Opening diameter 17/16".

Adapter plate for mounting WLRS/
WLRD covers to flush device boxes.

Description

Material

Cat. #

Description

Cat. #

Surface

Sheet steel

DS21

Flush Device Adapter

WLRA1

Surface

Sheet
aluminum

DS21 SA

Surface
or flush

Feraloy®
iron alloy
with gasket

DS21G

Also can be used to mount all covers with
four corner screws listed see pages
37, 39, 40, 41, 42 and 43 to flush device
boxes.
For standard and 3-pole, 2-wire
grounding type duplex convenience
receptacles. Gasket included.
Description
Material
Cat. #
Surface
or flush

www.crouse-hinds.com

Feraloy®
iron alloy

US: 1-866-764-5454

See page 42 for receptacle specifications and listings of
complete receptacle/cover combinations.
†Must be used with a wet locations rated wiring device.

DS23G

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

39

2F

Covers for Cast Iron or Aluminum Device Boxes

2F

Single Gang - Raintight Covers (Gasket Included)
Ordering Information

For general use snap switches.
Includes gasket.
Description
For standard
ON-OFF
operation

40

Material
Copper-free
aluminum

www.crouse-hinds.com

Cat. #
DS181

US: 1-866-764-5454

For general use snap switches.
Includes gasket.
Description
For standard
ON-OFF
operation.
With hole for
lock

CAN: 1-800-265-0502

Material
Die cast
aluminum

For general use snap switches.
Includes gasket.

Cat. #

Description

Material

Cat. #

DS185

For standard
operation.
Marked
ON-OFF
handle

Cast
aluminum

DS128

Copyright© 2013 Eaton’s Crouse-Hinds Business

Covers for Cast Iron or Aluminum Device Boxes

2F

Raintight

Single Gang - Switches and Motor Control Push Button
2F

Ordering Information

For manual motor starting switches.
Fits FS and FD boxes. Takes
Westinghouse switches MST01 (1-pole)
and MST02 (2-pole). Includes gasket.

Furnished with buttons for operating motor control push button switches.
Includes gasket.
Push Buttons
No. Color
Material

Description

Cat. #

Button (normally open) marked START

1

Green

Feraloy iron alloy

DS171F ➀

Description

Material

Cat. #

Button (normally closed) marked STOP

1

Red

Feraloy iron alloy

DS171G ➀

For standard
ON-OFF operation

Feraloy
iron alloy

DS199

Button (normally open) marked
START and button (normally closed)
marked STOP

1
1

Green
Red

Feraloy iron alloy

DS171 ➀

Description

No.

Color

Material

Cat. #

Two push button

2

Black

Feraloy iron alloy

DS171J ➀

➀

If desired, markings on indicating plates may be added to catalog number. Select from the list of

standard markings below:

HAND
EMER.
REVERSE
LGT. ON

CLOSE
DOWN
STOP

OFF
JOG
TRIP

AUTO.
FORWARD
OPEN

UP
START
ON

RUN
RESET
TEST

Heavy duty motor control push button switch
No. of
Buttons

Normal Positions

Cat. #

1

1 circuit universal

ED11

2

2 circuits universal

ED12†

†Two universal contact blocks, must be wired as two circuits, with one normally open and one normally closed.

DS Covers use the switches shown in the list below.
Cover

Takes Switch

Cover

Takes Switch

DS171
DS171G

ED12
ED11

DS171F
DS266

ED11
ED12

DS265

ED11

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

41

2F

Covers for Cast Iron or Aluminum Device Boxes

Weatherproof

2F

Single Gang - DS Receptacles and WP Plugs
Applications:
WP plugs and DS receptacles are used:
• Wherever dust, dirt, moisture and
corrosion are a problem
• Outdoors or in locations where frequent
washdowns occur, as in dairies and
food processing plants

Features:
DS receptacle housings are used:
• With FS and FD cast device boxes,
either surface mounted or installed flush
in a wall
• With single gang, two gang tandem and
multiple gang boxes having individual
cover openings
• A threaded cap which effectively seals
housing when not in use
WP plugs include:
• A molded Neoprene hood with integral
sleeve to seal the cord entrance
• An aluminum ring which clamps the
hood to receptacle housing face, to
complete watertight seal when plug is in
use

Certifications and
Compliances:

DS Receptacle
housings

WP Plugs

Grounding Type Receptacles
For Plugs with U shaped or Round Grounding Contacts
Rating

Cover With
Recept.
Cat. #
Diagram

Style
2-wire,
3-pole†

15 amps
DS96*
125 volts

Plug
Cat. #

NEMA: 5-15R

20 amps
DS222
125 volts

WP832

NEMA: 5-20R

2-wire,
3-pole†

WP930
NEMA: 6-20P

†Third pole grounded.
*Compliance

For listing of typical FS cast devices boxes, see pages 23 and 24.

Standard Materials:
• Receptacle housings: body – Feraloy®
iron alloy; cap – copper-free aluminum
• Plug exteriors: hood – Neoprene;
fastening ring – copper-free aluminum

Standard Finishes:
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint
• Copper-free aluminum – natural
• Neoprene – natural (black or yellow)

Electrical Rating Ranges:
• 15 amperes, 125 volts
• 20 amperes, 125, 250 volts

US: 1-866-764-5454

CAN: 1-800-265-0502

.500 to
.625

CC55

.500 to
.625

CC71

.500 to
.625

CC90

NEMA: 5-20P

*Compliance.

www.crouse-hinds.com

Repl.
Recept.
Cord Dia. Cat. #

NEMA: 5-15P

2-wire,
3-pole†

20 amps
DS290
250 volts

Diagram

WP820

NEMA: 6-20R

• UL Standards: 498; 514A
• NEMA/EEMAC: WD-1; WD-5
• CSA Standard: C22.2 No. 42*

42

CC Replacement
receptacle

Copyright© 2013 Eaton’s Crouse-Hinds Business

2F

Covers for Cast Iron or Aluminum Device Boxes
Single Gang - Pilot Light Covers, Extensions and Adapters

2F

Ordering Information

Pilot light (with transformer)†, FD only
For pilot light units
(furnished with jewels)
Jewel
Color

Description

Material

Surface

Sheet steel Red

Circuit Lamp
Voltage Base

Watts Cat. #

Cat. #

440

6

DS24

†Transformer 50–60 cycle, 440 / 110 volts.

For pilot light units
(furnished with jewel and gasket).

Candelabra

C333

Description

Jewel
Material Color Cat. #

EXF Extensions (takes covers and flush
rectangular wiring devices, or plug
receptacles with housings)

Surface or
flush

Feraloy
Red
iron alloy

Ext. Depth

Cat. #

1"
21/2"

EXF11
EXF21

DS24G

FS flush mounting adapter (can be
used with multi-gang bodies
having individual cover openings.
Furnished with gasket and screws)
Mtg. Style

Cat. #

Wall

FS031

Gaskets for use between device
boxes and covers.
Material

Cat. #

Neoprene

GASK91‡

‡Not recommended as watertight.

Pilot light unit (without transformer)
Circuit Lamp
Voltage Base

Watts Cat. #

110

6

Candelabra

C3310

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

43

2F

Covers for Cast Iron or Aluminum Device Boxes

2F

Two Gang
Ordering Information

For flush general use snap
switches with square handles

For duplex convenience receptacles,
standard and 2-wire, 3-pole grounding

Blank. Feraloy® iron alloy with gasket

Material

Cat. #

Description

Material

Cat. #

Description

Material

Cat. #

Sheet steel

S32232

Surface

Sheet steel

S232

Surface

Sheet steel

S1002

Surface or
flush

Feraloy
iron alloy

S1002G

Surface or
flush

Copper-free S1002G SA
aluminum

For flush general use snap switches
with square handles
Description

Material

Cat. #

For round plug
flush receptacles.
Surface

Sheet steel S32212

For GFI receptacles
Description

Material

Cat. #

Surface

Sheet steel

S232 GFI
For flush general use snap switches
with square handles
Description

Material

Cat. #

Surface

Sheet steel

S322

For round flush receptacles, duplex
convenience receptacles, standard
and 2-wire, 3-pole grounding
For standard and 2-wire,
3-pole grounding
Description

Material

For round plug
flush receptacles.
Surface

Sheet steel S212

Description

Material

Cat. #

Surface

Sheet steel

S21232

Cat. #

For flush general use snap
switches with square handles
Description
Surface or
flush

For 20 amp., 250 volt receptacles

44

www.crouse-hinds.com

US: 1-866-764-5454

Description

Material

Cat. #

2-pole, Surface

Sheet steel

S612

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Material
Feraloy
iron alloy

Cat. #
S322G

Covers for Cast Iron or Aluminum Device Boxes

2F

Two Gang
2F

Ordering Information

For flush general use snap switches
with square handles

Blank with gasket

With operating mechanism and gasket
Description

Material

Cat. #

Two gang. For
operation of
general use snap
switches. Surface
or flush

Feraloy®
DS1282
iron alloy

Description

Material

Cat. #

Surface

Sheet steel

S1003

Surface or
flush

Feraloy
iron alloy

S1003G

Surface or
flush

Copper-free S1003G SA
aluminum

Description
Surface, four gang†

Material
Cat. #
Sheet steel S324

†For FS094 and FD094 boxes.

*Includes gasket

Gasket for use between
device box and cover
For flush general use snap switches
with square handles
With operating mechanism and gasket
Description

Material

Cat. #

Three gang with
gasket. For
external operation
of general use
snap switches.
Surface or flush.

Feraloy
DS1283
iron alloy

Description

Material

Surface, three gang

Sheet steel S323

Cat. #

Description

Material

Cat. #

Two gang
Three gang
Four gang

Rubber
Rubber
Rubber

GASK434
GASK460
GASK461

Blank with gasket
Description

Material

Cat. #

Surface or flush

Feraloy
iron alloy

S1004G

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

45

2F

2F

FSE Receptacle and Breaker Assemblies

Applications:
• FSE series assemblies are used in
outdoor areas for supplying power in
remote locations, particularly parking
lots, automobile engine block heaters,
marinas, drive-in theaters, trailer
camps, etc.

Features:
•
•
•
•
•

Compact design.
Suitable for a variety of combinations.
U ground duplex receptacle.
Circuit breaker protection.
Breakers cannot be manually tripped.

FSE 6121

FSE 612

Ordering Information
Cat. #

Description

Certifications and
Compliances:

FSE612 Double face receptacle body only
FSE6121 Fitting complete with 1-15 amp. duplex receptacle and blank cover.

• CSA Standard C22.2 No. 18

FSE6122 Fitting complete with 2-15 amp. duplex receptacles.
FSE61212 Fitting complete with 1-15 amp. duplex receptacle and two 1- pole Minibreakers

Standard Materials:

FSE61211 Fitting complete with 1-15 amp. duplex receptacle and one 1- pole Minibreaker.

• Body and cover – copper-free aluminum

Other combinations available on request

Standard Finishes:
• Copper-free aluminum – natural

Electrical Ratings:
• 15A

120V

Size:
• 2" integral hub for pole mounting.

46

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Bodies and Outlet Boxes
Hazardous

3F

Page No.

Application/Selection

see page 48

Lubricants
HTL
STL

see page 63
see page 63

Conduit Bodies & Outlet Boxes
Cylindrical
EKC

see page 60

90° Elbow
FE
LBH
LBY

see page 62
see page 61
see page 61

Rectangular
OE

see page 59

Round
C30 and C31 for IEC Applications
CPS
GUA
EAB
EAB ATEX
EAJ
GUR Universal

see page 57
see page 58
see pages 50–51
see page 54
see page 55
see page 56
see page 53

Tees
Short Radius
ET
FT

www.crouse-hinds.com

US: 1-866-764-5454

see page 61
see page 62

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

47

3F

Description

3F

Condulet® Conduit Bodies and
Outlet Boxes

3F

Application and Selection
Applications:

Considerations for Selection:

Hazardous area conduit bodies and outlet boxes are installed in rigid
conduit systems in Class I and II hazardous locations to:

• Determine the area classification per National Electrical Code
Hazardous Area Groups. Based on this classification, select the
product families that are acceptable for use in the particular
location.:

• Protect conductors
• Act as pull and splice boxes

• Establish functional physical requirements these will help to
determine box size, cover, shape and mounting for the particular
installation.

• Connect lengths of conduit
• Change conduit direction

• Each product family has features suitable for specific functions:

• Provide access to conductors for maintenance and future system
changes

• i.e., boxes used as mountings for lighting fixtures are generally of
a small size, and provided with mounting lugs when required to
support lighting fixtures.

• Act as mounting outlets for fixtures (with appropriate covers)
• Act as sealing fittings (with appropriate covers)

• Boxes used for wire pulling should generally be larger to provide
room for easy pulling.

Options and Accessories:

• Boxes used to splice and/or tap conductors should be large
enough to permit ease of work and sufficient room for the required
size and number of conductors.

• Flat blank covers (surface and flanged flush), fixture support and
sealing covers and extensions are available. See specific product
listing for details.
• Lubricant (STL and HTL) are available to make joints raintight,
provide for easy cover removal and to lubricate shafts over a wide
temperature range.

• Hub size and configuration – dependent on the conduit system
configuration and the conduit size used.
• Material and finish – determine from environmental conditions
(corrosive fumes, weather, buried in concrete, etc.)

• Corro-free™ epoxy powder coat – information available on
request.

Quick Selector Chart

Series

NEC
Class I & II
Groups

GUA

C, D E, F, G

Mtg. ltg. fixt., taps, pulling,
splicing

2–5

EAJ

A, B, C, D E, F, G

Pulling, splicing, taps

33/16 & 5

1

Pulling, splicing, taps

98mm (C30)
130mm (C31)

1

Pulling, splicing, taps

3

1

Pulling, splicing, taps

33/4

1

Fixt. support, pulling,
splicing

31/2

1

IEC
Certifications

C30 / C31

Ex II 2 G EEx d IIC T6
Ex II 2 D IP66 T 85ºC

EAB

A, B, C, D E, F, G

EAB ATEX

A, B, C, D E, F, G

CPS

C, D E, F, G

II 2 G EEx d IIC T5
PTB 05 ATEX 1052

Normal
Function

Cover
Opening
Diameter

Hub
Size†
1
/2-2

Cover
Type
Threaded

/2-2

Threaded

/2-1

Threaded

/2-1

Threaded

/2-1

Threaded

/2 & 3/4

Ground joint

/2-1

Ground joint

OE

C, D E, F, G

Pulling

1

ET

C, D E, F, G

Stub up

1

Stub up

20mm 25mm

FT

Flameproof, Exd, IIB,
IP67, Zone 1
Combustible Dust Zone
21 & 22

/2-1
Threaded

LBY

C, D E, F, G

Pulling

1

/2 – 11/4

Threaded

LBH

B, C, D E, F, G

Pulling

1

/2-4

Ground joint

Pulling

20mm 25mm

Threaded

FE

Flameproof, Exd, IIB,
IP67, Zone 1
Combustible Dust Zone
21 & 22

EKC

C, D E, F, G

Pulling

1

GUR

C, D E, F, G

Pulling, splicing

1

†See following table for standard hub configuration.

48

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

/2-3

Ground joint

/2-1

Threaded

3F

Condulet® Conduit Bodies and
Outlet Boxes
Standard Shape and Hub Selector
Shape

3F

Hub Style

Series

Page

GUA

GUAB

GUAC

GUAD

GUAL

GUAM

GUAN

GUAT

GUAW

GUAX

see pages
50–52
GUA

EABC
EAB

see
page 54

C30 / C31

see
page 57

EAJ

see
page 56

CPS

see
page 58

GUR

see
page 53

OE

see
page 59

EAJB

EAJC

EABL

EAJD

EAJL

EABT

EABX

C30 /
C31

C30 /
C31

EAJT

EAJX

EABY

CPS

GUR

OELB

OEC

OELL

OELR

OET

The fittings below are available only in the configurations shown.

LBH

see page 61

LBY

see page 61

FE

www.crouse-hinds.com

see page 62 EKC

US: 1-866-764-5454

see page 60

CAN: 1-800-265-0502

ET

see page 61

FT

see page 62

Copyright© 2013 Eaton’s Crouse-Hinds Business

49

3F

Condulet® Conduit Outlet
Boxes With Covers

3F

GUA Series
Applications:

Options:

GUA series conduit outlet boxes are
installed within hazardous area conduit
systems to:
• Protect conductors in threaded
rigid conduit
• Act as pull and splice boxes
• Connect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes
• Act as mounting outlets for fixtures
(with appropriate covers)
• Act as sealing fittings (with appropriate
covers)

Description
Suffix
Bodies – copper-free aluminum
SA†*
Covers – Feraloy iron alloy –
electrogalvanized and aluminum
acrylic paint
WOD
GUA Form 6 (with 3" cover opening)
are available with optional cover
with viewing window.
VW
Corro-free epoxy powder coat
S752
To order box less cover add "0" to end of
catalog number ie.GUAT260.

Features:

GUA

Certifications and
Compliances:

GUAC

• NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• ANSI Standard: C33.27
• CSA Standard: C22.2 No. 30
• NEMA/EEMAC 3, 4

Standard Materials:
• Bodies – Feraloy iron alloy
• Covers – Copper-free aluminum

Standard Finishes:

GUAB

When assembled with sealing type cover, GUA series
outlet boxes provide adequate sealing for 40% fill in
hazardous areas – Class I, Groups C, D; Class II, Groups
E, F, G; and Class III. Seals can be made in either
horizontal or vertical positions. Use Chico® "A" sealing
compound or Chico® SpeedSeal only. Conductor splices
or connections must not be made in enclosures where
sealing compound is to be used per NEC.

GUA conduit boxes have:
• Neoprene "O" ring standard to meet
NEMA 4 requirements
• Cast ears on cover to permit easy
removal and tightening
• Four standard mounting pads except for
boxes with bottom hubs
• Threaded cover openings
• Ten different hub arrangements
• Taper threaded hubs to provide
grounding continuity
• Smooth integral hub bushing protects
conductor insulation when pulling
• Surface covers furnished with boxes
• Sealing covers, dome covers, and fixture
hanger covers are available
• Cover threads are 12 pitch

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4
11/2

2
2
3
3
3
35/8
5

GUA14
GUA24
GUA16
GUA26*
GUA36
GUA47
GUA59

Hub
Size

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4
11/4
11/2
2

2
2
3
3
3
35/8
5
5
5

GUAC14†
GUAC24†
GUAC16*
GUAC26*
GUAC36*
GUAC47†
GUAC49
GUAC59†
GUAC69†

1

†Available in copper-free aluminum, add suffix -SA.
*Available in copper-free aluminum, add suffix -SA. GUA
outlet boxes marked with * when ordered with suffix -SA
are listed for Class I, Division 1 & 2, Groups B, C and D,
Class II, Division 1, Groups E, F, G and Class III.
Covers have 16 pitch threads. Replacement cover
is a GUA06-GB.

• Hub – 1/2" to 2"
• Cover opening – 2" to 5" dia.
50

www.crouse-hinds.com

US: 1-866-764-5454

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4
11/2
2

2
2
3
3
3
35/8
5
5

GUAB14†
GUAB24
GUAB16*
GUAB26*
GUAB36*
GUAB47†
GUAB59†
GUAB69†

1

GUAD

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4

2
2
3
3
3
5

GUAD14†
GUAD24
GUAD16
GUAD26†
GUAD36†
GUAD49

Dimensions
In Inches:

All others

GUAB Only
Cover
Opening
Dia.

• Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
• Aluminum – natural

Size Ranges:

Hub
Size

1

1

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4, 7CD, 9EFG

CAN: 1-800-265-0502

GUA, GUAD, GUAM,
GUAW, GUAX
Cat. #

a

b

c

d

14
24
16
26
36
37
47
49
59
69

21/2
21/2
31/2
31/2
31/2
41/4
41/4
53/4
53/4
53/4

113/16
2
2
2
25/16
25/16
211/16
313/16
313/16
41/16

13/4
2
17/8
17/8
23/16
23/8
23/4
33/4
33/4
4

/8
/4
5
/8
3
/4
7
/8
7
/8
13/32
13/32
19/32
19/16

Length of Hub
Hub Size
1
/2 - 3/4
1 – 11/4
11/2 – 2

Copyright© 2013 Eaton’s Crouse-Hinds Business

5

3

Dimension "e"
Length
7
/8
1
11/16

Condulet® Conduit Outlet
Boxes With Covers
GUA Series

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4
11/4
11/2
2

2
2
3
3
3
35/8
5
5
5

GUAL14†
GUAL24†
GUAL16*
GUAL26*†
GUAL36*
GUAL47†
GUAL49†
GUAL59†
GUAL69†

1

GUAX

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4
11/2
2

2
2
3
3
3
35/8
5
5

GUAN14
GUAN24
GUAN16
GUAN26
GUAN36†
GUAN47
GUAN59†
GUAN69

1

GUAM

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
1
11/4
11/4
11/2
2

2
2
3
3
3
35/8
35/8
5
5
5

GUAX14†
GUAX24†
GUAX16*
GUAX26*
GUAX36*
GUAX37†
GUAX47†
GUAX49
GUAX59†
GUAX69†

1

GUAT

GUAN

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
1
11/4
11/4
11/2
2

2
2
3
3
3
35/8
35/8
5
5
5

GUAT14†
GUAT24†
GUAT16*
GUAT26*
GUAT36*
GUAT37
GUAT47†
GUAT49†
GUAT59†
GUAT69†

1

GUAW

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4
1
11/4
2

2
2
3
3
3
35/8
5

GUAM14†
GUAM24
GUAM16
GUAM26
GUAM36
GUAM47
GUAM69

1

3F

GUAL

3F

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4, 7CD, 9EFG

Hub
Size

Cover
Opening
Dia.

Cat. #

/2
3
/4
1
/2
3
/4

2
2
3
3

GUAW14†
GUAW24†
GUAW16
GUAW26*†

1

Dimensions
GUAN

GUAC, GUAT

GUAB, GUAL

Cat. #

a

b

c

d

Cat. #

a

b

c

d

Cat. #

a

b

c

d

14
24
16
26
36
37
47
49
59
69

21/2
21/2
31/2
31/2
31/2
41/4
41/4
53/4
53/4
53/4

21/4
2
2
2
25/16
25/16
211/16
313/16
313/16
41/16

23/16
2
17/8
17/8
23/16
23/8
23/4
33/4
33/4
4

5

/8
3
/4
5
/8
3
/4
7
/8
7
/8
13/32
15/32
19/32
19/16

14
24
16
26
36
47
59
69

21/2
21/2
31/2
31/2
31/2
41/4
53/4
53/4

21/8
25/16
2
2
25/16
211/16
41/16
41/16

21/16
21/4
17/8
17/8
23/8
23/4
4
4

5

/8
3
/4
3
/4
3
/4
7
/8
13/32
19/32
19/16

14
24
16
26
36
47
49
59
69

21/2
21/2
31/2
31/2
31/2
41/4
53/4
53/4
53/4

21/4
21/2
2
2
25/16
211/16
313/16
313/16
41/16

23/16
27/16
17/8
17/8
23/16
23/4
33/4
33/4
4

5

/8
/4
5
/8
3
/4
7
/8
13/32
15/32
19/32
19/16
3

†Available in copper-free aluminum, add suffix -SA.
*Available in copper-free aluminum, add suffix -SA. GUA outlet boxes marked with * when ordered with suffix -SA are listed for Class I, Division 1 & 2, Groups B, C and D, Class II,
Division 1, Groups E, F, G and Class III. Covers have 16 pitch threads. Replacement cover is a GUA06-GB.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

51

3F

Covers and Accessories

3F

For GUA Condulet® Conduit Outlet Boxes
Applications:
Threaded covers, canopies and extensions
are used:
• To provide a seal in hazardous areas
(sealing cover). See note below.
• To mount pendant lighting fixtures such
as EVA listed in lighting section (fixture
canopy)
• To mount EVA pendant lighting fixtures
on cover which is then screwed into
outlet box without twisting conductors
(union hub cover)
• To mount pendant lighting fixtures on
cover which is then screwed into outlet
box as above, for wiring after fixture
stem is installed (nipple cover)
• To provide means of increasing outlet
box depth (threaded extension)

GUA Threaded Extension

Sealing Cover

Cover
Opening
Dia.

Ext.
Depth

Cat. #

Cover
Opening
Dia.

Thread
Pitch

Cat. #

3

1 /4

GUA0631

2
3
3
35/8
5

12
12
16
12
12

GUA041
GUA062
GUA062 GB*
GUA072†
GUA092

GUA
Cover
Opening

Replacement O-Ring
Gasket Cat. #

2"
3"
35/8"
5"

GASK1713
GASK1151
GASK1589
GASK925

Features:
• Surface covers are supplied with GUA
boxes
• Sealing cover has removable plug for
filling enclosure with sealing compound
after installation. Sealing cover meets
40% fill requirement of the NEC®. See
note below.
• Fixture canopy has a threaded cover in
its side to provide access for making
splices or taps. Fixture with its conduit
stem and canopy can be assembled and
wired before installation and conductors
can be spliced in canopy after it has
been screwed into the body
• Cover threads are 12 pitch.

1

Nipple Cover

Surface Cover

Cover
Opening
Dia.

Thread
Pitch

Cat. #

2
3
3
35/8
5

12
12
16
12
12

GUA04
GUA06
GUA06 GB*
GUA07
GUA09

Cover
Opening
Dia.

Fixt.
Stem
Size

Thread
Pitch

Cat. #

3

3

/4

12

GUA0672

Fixture Cover
Union Hub Type

Standard Materials:
• Surface and dome covers, union hub
covers, nipple covers – copper-free
aluminum
• Sealing covers, fixture canopies,
threaded extensions – Feraloy®
iron alloy

Dome Cover

• Aluminum – natural
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint

Options:
Suffix
S752
WOD

Size Ranges:

Cover
Opening
Dia.

Ext.
Depth

Thread
Pitch

Cat. #

2
3
35/8
35/8
5
5

2
2
2
4
4
10

12
12
12
12
12
12

GUA047
GUA067
GUA077
GUA0716
GUA514
GUA5110

• Fixture stems – 3/4"
• Body openings – 2" to 5"

www.crouse-hinds.com

Thread
Pitch

Cat. #

3

3

/4

12

GUA0687

US: 1-866-764-5454

Cover
Opening
Dia.

Fixt.
Stem
Size

Thread
Pitch

Cat. #

3

3

/4

12

GUA068

†Also used with GUP bodies see page 753 or
GU and GUE bodies see page 722.
*GUA covers with 16 pitch threads are used with GUA
bodies ordered with -SA suffix identified with * symbol
see pages 50–51.

Note: Depth of sealing compound in body must satisfy
requirements of NEC section 501-5 (C-3). Splices and
taps in sealing fittings are prohibited by NEC.

52

Fixt.
Stem
Size

Fixture Canopy

Standard Finishes:

Description
Corro-free™ epoxy powder coat
To order an iron surface cover

Cover
Opening
Dia.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Outlet
Boxes With Covers

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 4

GUR Series

3F

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

3F

Applications:
GUR conduit outlet boxes are installed within hazardous areas:
• To protect conductors in threaded rigid conduit
• To act as pull and splice boxes
• To connect lengths of conduit
• To provide access to conductors for maintenance and future
system changes
• To change conduit direction
• Where space is limited, such as underneath gasoline pumps

Features:
GUR outlet boxes feature:
• Neoprene O-ring standard in cover to meet NEMA 4/UL Type 4
requirements
• Internal green ground screw
• Five standard hubs with three pipe plugs included
• Threaded cover opening
• Recesses in cover to assist in cover tightening and removal
• Smooth, integral hub bushing to protect conductor insulation
when pulling
• Compact design for confined spaces
• UL and cUL listing
• Optional all-aluminum construction

Certifications and Compliances:
• NEC/CEC
Class I, Division 1 and 2, Groups C and D
Class II, Division 1, Groups E, F and G
Class III
Zone 1 and 2
• UL Standard 1203
• cUL to CSA Standard C22.2 No. 30
• NEMA 4

Ordering Information:
Hub Size

Cat. #

/2"
3
/4"
1"

GUR1
GUR2
GUR3

1

Dimensions

Standard Materials:

In Inches:

• Bodies – Feraloy® iron alloy
• Covers – copper-free aluminum

Standard Finishes:
• Feraloy iron alloy – electrogalvanized with aluminum acrylic paint
• Aluminum – natural

Options:
Description
Bodies – copper-free aluminum

Suffix
SA

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

53

3F

Condulet® Conduit Outlet
Boxes With Covers

3F

EAB Series
Applications:

EABX

EABC

EAB series conduit outlet boxes are
installed in conduit systems within
hazardous areas to:
• Provide protection against exterior
explosion where acetylene, hydrogen
and other hazardous gases are present
• Protect conductors in threaded
rigid conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes

Hub
Size

Cat. #

/2
3
/4
1

EABC16†
EABC26
EABC36†

1

EABT

Hub
Size

Cat. #

/2
/4
1

EABT16†
EABT26†
EABT36†

1
3

Hub
Size

Cat. #

/2
3
/4
1

EABX16†
EABX26†
EABX36†

1

EABY

Features:
EAB series conduit outlet boxes have:
• Five different hub configurations
• Taper threaded hubs to provide ground
continuity
• Smooth integral hub bushing to protect
conductor insulation when pulling
• Threaded cover openings
• Surface covers furnished with boxes
• Neoprene "o"-ring gasket and green
ground screw are both standard.
• Four standard mounting pads,
except for EABY.
• Cover threads are 16 pitch.

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3,4,7ABCD,9EFG

EABL

Certifications and
Compliances:

Hub
Size

Cat. #

/2
3
/4

EABY16†
EABY26†

1

Replacement Cover:
Size

Cat. #

3"

EAB06

Replacement O-Ring:

• NEC/CEC:
Class I, Division 1 & 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Standard Finishes:

Hub
Size

Cat. #

/2
/4
1

EABL16†
EABL26†
EABL36†

1
3

Cat. #

Replacement O-Ring

GASK1151

Fixture Cover
Union Hub Type

Dimensions

• Feraloy – electrogalvanized and
aluminum acrylic paint
• Aluminum – natural

In Inches:

Standard Materials:
• Bodies – Feraloy® iron alloy
• Covers – Copper-free aluminum

Options:
Description
Bodies – copper-free aluminum
Covers – Feraloy iron alloy –
electrogalvanized and aluminum
acrylic paint
Corro-free epoxy powder coat

Description

Cover
Opening
Dia.

Fixt.
Stem
Size

Cat. #

3"

3

/4

EAB0687*

Suffix
SA†*
WOD
S752

EAB Series

Size Ranges:

Cat. #

a

b

c

d

e

f

• Hub – /2" to 1"
• Cover opening – 3" dia.

16
26
36

33/4
33/4
33/4

217/32
225/32
225/32

11/2
13/4
13/4

3

/4
7
/8
7
/8

55/16
59/16
59/16

33/32
33/32
33/32

1

EAB Series
†Available in copper-free aluminum, add suffix -SA.
*EAB0687 is listed for Group C & D only.

54

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Outlet
Boxes With Covers
EAB Series with UL, cUL and
ATEX Certifications

Options:

EAB ATEX series conduit outlet boxes are
installed in conduit systems within
hazardous areas to:
• Provide protection against exterior
explosion where acetylene, hydrogen
and other hazardous gases are present
• Protect conductors in threaded
rigid conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes

Description

EABY
Suffix to be
added to Cat. #

Covers – Feraloy iron
alloy – electrogalvanized
and aluminum acrylic
paint
Corro-free epoxy
powder coat

WOD
S752

Size Ranges:
• Hub – 1/2" to 1"
• Cover opening – 3" dia.

Certifications and
Compliances:

/2

1

/2

1

/4
/4

3

Feraloy® Iron
Copper-free
Aluminum
Feraloy® Iron
Copper-free
Aluminum

EABY16 ATEX
EABY16 SA ATEX
EABY26 ATEX
EABY26 SA ATEX

Replacement Cover:
Hub
Size Body Material

Cat. # †

/2

EABX16 ATEX

1

/2

1

/4

3

/4

3

1
1

• NEC/CEC:
Class I, Division 1 & 2,
Groups A, B, C, D
Class II, Division 1 & 2, Groups E, F, G
Class III
II 2 G EEx d IIC T5
PTB 05 ATEX 1052
• UL Standard: 1203
• cUL Listed to CSA Standard:
C22.2 No. 30
• Type 4 Enclosure
• IP66

Hub
Size Body Material Cat. # †

3

EABX

Features:
EAB ATEX series conduit outlet boxes
have:
• Two different hub configurations
• Taper threaded hubs to provide ground
continuity
• Smooth integral hub bushing to protect
conductor insulation when pulling
• Threaded cover openings
• Surface covers furnished with boxes
• Neoprene "o"-ring gasket and green
ground screw are both standard.
• Cover threads are 16 pitch.

3F

Applications:

3F

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Type 4 Enclosure / IP66

Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1 & 2, Groups E, F, G
II 2 G EEx d IIC T5
PTB 05 ATEX 1052
UL and cUL Listed

Feraloy Iron
Copper-free
Aluminum
Feraloy® Iron
Copper-free
Aluminum
Feraloy® Iron
Copper-free
Aluminum
®

EABX16 SA ATEX
EABX26 ATEX

Size

Cat. #

3"

EAB06

Replacement O-Ring:
Description

Cat. #

Replacement O-Ring

GASK1151

EABX26 SA ATEX
EABX36 ATEX
EABX36 SA ATEX

Fixture Cover

Dimensions

Union Hub Type

In Inches:

Standard Materials:

Cover
Opening
Dia.

Fixt.
Stem
Size

Cat. #

3"

3

/4

EAB0687*

• Bodies – Feraloy® iron alloy or copperfree aluminum
• Covers – Copper-free aluminum

Standard Finishes:

EAB Series

• Feraloy – electrogalvanized and
aluminum acrylic paint
• Aluminum – natural

Cat. # a

EAB Series

16
26
36

33/4
33/4
33/4

b

c

d

e

f

217/32
225/32
225/32

11/2
13/4
13/4

3

/4
7
/8
7
/8

55/16
59/16
59/16

33/32
33/32
33/32

†Available with 6-point Phoenix MBK type terminal block
mounted on DIN rail. Add suffix DIN16 before ATEX.
Ordering example: EABX26 DIN16 ATEX
*EAB0687 is listed for Group C & D only.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

55

Condulet® Conduit Outlet
Boxes With Covers

3F

3F

EAJ Series

EAJX

Applications:

Options:

EAJ series conduit outlet boxes are
installed in conduit systems within
hazardous areas to:
• Protect conductors in threaded rigid
conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes
• Act as mounting outlets for fixtures (with
appropriate covers)
• Act as sealing fittings (with appropriate
covers)

Description
Bodies – copper-free aluminum
Covers – Feraloy iron alloy –
electrogalvanized and aluminum
acrylic paint
Corro-free epoxy powder coat

Certifications and
Compliances:

Standard Materials:
• Body – Feraloy® iron alloy
• Cover – copper-free aluminum

Standard Finishes:
• Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
• Aluminum – natural

56

www.crouse-hinds.com

US: 1-866-764-5454

SA†

33/16
33/16
33/16

WOD
S752

Hub.
Size Cat. #
/2
/4
1

1
3

EAJX16†
EAJX26†
EAJX36†

EAJ Threaded Covers
• Hub – 1/2" to 2"
• Cover opening – 33/16" to 5" dia.

EAJB
Cover
Opening
Dia.
33/16
33/16
33/16

EAJC

Cover
Opening
Dia.
33/16
33/16
33/16

EAJD

Flat Covers
Hub
Size Cat. #
/2
/4
1

1
3

EAJB16†
EAJB26†
EAJB36†

Cover Opening Dia.

Cat. #

33/16
5

EAJ06
EAJ09

Dome Covers
Cover
Opening
Dia.
Depth Cat. #

Hub
Size Cat. #
/2
/4
1

1
3

EAJC16†
EAJC26†
EAJC36†

33/16

2

EAJ0612

Fixture Covers
Union Hub Type

Cover
Opening
Dia.

Hub
Size Cat. #

33/16
33/16
33/16

/2
3
/4
1
1

EAJD16†
EAJD26†
EAJD36†

Cover
Opening
Dia.

Fixt.
Stem
Size Cat. #

33/16

3

/4

EAJ0687*

Dimensions
In Inches:

EAJL

• NEC/CEC:
Class I, Division 1 & 2, Groups A‡,B,C,D
Class II, Division 1, Groups E,F,G
Class II, Division 2, Groups F,G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Cover
Opening
Dia.

Suffix

Size Ranges:

Features:
EAJ conduit outlet boxes have:
• Water shedding cover – suitable for wet
locations when mounted in upright
position
• External cover threads on body protecting
conductors from damage during pulling
• No pinching of conductors during cover
installation
• Six different hub arrangements
• Taper threaded hubs to provide ground
continuity
• Smooth integral hub bushing to protect
conductor insulation when pulling
• Internally threaded cover openings for
additional wiring room
• Flat overlapping threaded covers
furnished with boxes
• Weather-resistant finish
• Green ground screw standard in all boxes
• Four standard mounting pads, except for
EAJB and EAJD

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

Cl. I, Div. 1 & 2, Groups A‡, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 4, 7ABCD, 9EFG

Cover
Opening
Dia.
33/16
33/16
33/16

EAJT

Hub
Size Cat. #
/2
/4
1

1
3

EAJL16†
EAJL26†
EAJL36†

Cover
Opening
Dia.

Hub
Size Cat. #

33/16
33/16
33/16
5
5
5

/2
3
/4
1
11/4
11/2
2

CAN: 1-800-265-0502

1

EAJT16†
EAJT26†
EAJT36†
EAJT49†‡
EAJT59†‡
EAJT69†‡

Cat. # a
16
26
36
49
59
69

33/4
33/4
33/4
53/4
53/4
53/4

b

c

217/32
225/32
225/32
41/16
41/16
41/16

11/2 3/4
13/4 7/8
13/4 7/8
23/16 13/32
3
11/2
3
11/2

d

e

f

55/16
59/16
59/16
75/16
713/16
713/16

33/32
33/32
33/32
43/4
43/4
43/4

*EAJ0687 is listed for Group C & D only.
†Available in copper-free aluminum, add suffix -SA.
‡Form 9 products with 5" cover opening are not
suitable for Group A.

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Outlet
Boxes With Covers

Ex II 2 G EEx d IIC T6
Ex II 2 D IP66 T 85ºC

Zone 1, 2, 21 and 22

3F

for IEC Applications
C30 Series

C31 Series

3F

Applications:
C30 and C31 series conduit outlet boxes
are installed in electrical systems within
hazardous areas to:
• Provide protection against exterior
explosion where acetylene, hydrogen
and other hazardous gases are present
• Protect conductors in threaded rigid
conduit
• Act as pull and splice boxes
• Interconnect lengths of conduit
• Change conduit direction
• Provide access to conductors for
maintenance and future system changes

Features:
C30 and C31 series conduit outlet
boxes have:
• Taper threaded hubs to provide ground
continuity
• Smooth integral hub bushing to protect
conductor insulation when pulling
• Threaded cover openings
• Surface covers furnished with boxes
• Neoprene "o"-ring gasket and green
ground screw are both standard
• Cover threads are 16 pitch

Ordering Information
Series

Shape

Hub Size

C30
C30
C30
C30
C31
C31
C31
C31
C31
C31

T
T
X
X
T
T
T
X
X
X

3
3
4
4
3
3
3
4
4
4

x
x
x
x
x
x
x
x
x
x

/ 2"
3
/ 4"
1
/ 2"
3
/ 4"
1
/ 2"
3
/ 4"
1"
1
/ 2"
3
/ 4"
1"
1

Cat. # †
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR

000
000
000
000
000
000
000
000
000
000

Certifications and
Compliances:

Description

Cat. #

• IEC:
Ex d IIC T6
Ex tD A21 IP67 T85ºC
EC-Type examination certificate LOM
02 ATEX 2037 X
Compliant to EN60079-0
• IP67

C30
C30
C30
C30
C31
C31
C31

NOR
NOR
NOR
NOR
NOR
NOR
NOR

Standard Materials:

Dimensions

• Bodies – Light alloy, natural finish
• Covers – Light alloy, natural finish

In Inches:

001
001
001
001
111
111
111
111
111
111

151
151
151
151
150
150
150
150
150
150

181
199
206
214
001
002
003
004
005
006

Accessories
Mounting plate with pillar terminals 4 x 4mm2
support rail DIN 46877
mounting plate without terminals
pending support
mounting plate with pillar terminals 4 x 4mm2
mounting plate without terminals
support rail DIN 46877

000
000
000
000
000
000
000

001
000
000
000
111
000
000

151
115
115
115
150
115
115

222
314
302
311
009
306
315

Technical Specifications
Operating temperature
range

-50ºC to +55ºC

Degree of protection
Rated voltage
Rated current
Terminals

IP67
up to 690V
Acc. terminals
C30 Series:
up to 6mm2
C31 Series:
up to 10 mm2

C31 Series

C30 Series
†Other entries available upon request.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

57

Condulet® Conduit Outlet
Boxes With Covers

3F

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 7CD,9EFG

3F

CPS Series
Applications:

Box with Hub Cover

CPS series conduit outlet boxes are
installed in conduit systems in hazardous
areas to:
• Protect conductors in threaded rigid
conduit
• Act as pull and splice boxes
• Change conduit direction
• Interconnect lengths of conduit
• Act as fixture hangers with hub covers
• Provide access to conductors for
maintenance and future system changes

Hub Size
Body‡
/4
3
/4

CPS conduit outlet boxes have:
• Two types of cover:
blank for splice or pull box use
threaded hub for mounting light fixtures
• Wide, accurately machined body and
cover mating surfaces, to insure
flametight joint
• Blind tapped holes for cover screws to
further insure flametightness
• Removable mounting feet for flush or
surface mounting to wall or ceiling

CPS Covers

Blank Covers

3

Features:

Cover

Cat. #

/2
3
/4

CPS12021
CPS12022

1

Description

Cat. #

Form 20

CPS026

Hub Covers*

‡Furnished with four /4" standard taper tapped,
integrally bushed hubs. Three hubs are plugged.
3

Box with Blank Cover

Description
Form 20
Form 20

Certifications and
Compliances:

Hub Size

Cat. #

/4

CPS12026

3

• NEC/CEC
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard C22.2 No. 30

*Fixture weight up to 125 lbs.

Dimensions
In Inches:

Standard Materials:
• Feraloy® iron alloy

Standard Finishes:
• Electrogalvanized and aluminum
acrylic paint

Options:
Description
Corro-free™ epoxy powder coat

Suffix
S752

Complete line of fixture hangers are located in section 7L of this catalog.

58

www.crouse-hinds.com

Explosionproof
Dust-Ignitionproof

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Hub
Size Cat. #
/2
/4

1
3

CPS021
CPS022

Condulet® Conduit Bodies
With Covers

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 7CD, 9EFG

OE Series

OEC

OET

3F

Applications:

3F

OE series are installed in conduit systems
within hazardous areas to:
• Protect conductors in threaded
rigid conduit
• Act as pulling and splice fittings
• Interconnect lengths of conduit
• Change direction of conduit
• Provide access for maintenance and
future system changes

Features:
OE conduit outlet bodies have:
• Taper threaded hubs for ground
continuity
• Smooth integral hub bushings to protect
conductor insulation when pulling
• Five different hub arrangements
• Accurately machined body with blind
tapped screw holes
• Most compact design of all hazardous
area outlet bodies

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Hub Size
1
/2
3
/4
1

Cat. #
OEC1
OEC2
OEC3 SA

Hub Size

Cat. #

/2
3
/4
1

OET1
OET2
OET3 SA

1

OELB

OELL

Hub Size
/2
/4
1

1
3

Cat. #

Hub Size

Cat. #

OELL1
OELL2
OELL3 SA

/2
3
/4
1

OELB1
OELB2
OELB3 SA

1

OELR

Standard Materials:
• Feraloy® iron alloy (1/2" and 3/4" fittings)
• Copper-free aluminum (1" fittings)

Standard Finishes:
• Electrogalvanized and aluminum
acrylic paint

Description
Corro-free™ epoxy powder coat

Cat. #

/2
3
/4
1

OELR1
OELR2
OELR3 SA

1

Dimensions
In Inches:

Options:

Hub Size

Suffix
S752

Size Ranges:
• Hub - 1/ 2" to 1"

OE Series
Hub
Size in. a
1
/2
41/16
3
/4
45/16

www.crouse-hinds.com

b

c

d

e

f

19/16
17/8

113/16
21/16

11

/16
11
/16

7

/8
7
/8

5

US: 1-866-764-5454

/8
/4

3

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

59

Condulet® Conduit Bodies
With Covers

3F

Cl. I, Div. 1 & 2, Groups C, D Explosionproof
Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 7CD,9EFG

3F

EKC Series

Ordering Information

Applications:
EKC series conduit outlet bodies are installed
in conduit systems within hazardous areas to:
• Provide convenient opening in conduit
system for pulling or splicing conductors

EKC

Features:
EKC bodies have:

Hub Size

Cat. #

• Accurately machined body and cover
mating surfaces to ensure flametight
joint when properly assembled

1
11/4
11/2
2
21/2
3

EKC30
EKC40
EKC50
EKC60
EKC70
EKC80

• Extra long cover opening to facilitate
pulling and splicing of conductors
• Taper threaded hubs and integral
bushing for rigid threaded conduit

Dimensions
In Inches:

Certifications and
Compliances:
• NEC:
EKC 30 – 60
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EKC 70, 80
Class I, Division 1 & 2, Group D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

EKC

Standard Materials:
• EKC bodies – Feraloy iron alloy

EKC

Standard Finishes:
• Feraloy – electrogalvanized and
aluminum acrylic paint

Size

a

b

c

d

e

f

1 – 11/4
11/2 – 2
21/2 – 3

125/8
1515/16
213/4

31/16
37/8
51/2

37/16
45/16
6

13/4
21/2
33/4

9
12
16

4
5
65/8

Options:
Description
EKC series:
Corro-free™ epoxy powder coat

Suffix
S752

Size Ranges:
• EKC bodies – hub size – 1" to 3"

60

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Condulet® Conduit Bodies
With Covers; Elbows and Tees
LBH, LBY, ET Series

Features:
LBH bodies have:
• Cover openings on an angle, permitting
conductors to be pulled straight through
hubs from either direction
• Domed covers to permit easy conductor
bends (relieves strain on insulation)
• Taper threaded hubs with integral
bushings
LBY elbows have:
• Maximum volume for bends within a
compact overall size
• Screw on cover for ease of installation and
removal
• Over opening on an angle, permitting
conductors to be pulled straight through
either hub
• Taper threaded hubs and integral bushing
for rigid threaded conduit
ET short radius tees have:
• Compact size and small radius of bend for
use in concealed, or open conduit
systems.
• Particularly suited for use in shallow floors
or partitions
• Taper threaded hubs and integral bushing
for rigid threaded conduit

Certifications and
Compliances:

Options:

3F

Applications:
LBH conduit outlet bodies are installed in
hazardous areas to:
• Act as pull outlets especially for
conductors that are stiff due to large size
or type of insulation
• Make 90° bends in conduit system,
allowing straight pull in either direction
• Provide for conduit service entrance to
buildings
• Provide for conductor entrance to motors
• Provide access to wiring for maintenance
and future system changes
LBY elbows are installed in conduit systems
within hazardous areas to:
• Make 90° bends in conduit systems where
space is limited
• Act as pull outlets
• Provide access to conductors for
maintenance and future system changes
ET series short radius tees are installed in
conduit systems within hazardous areas to:
• Allow single conduit stub up to outlet and
device boxes located above or below main
conduit runs. Eliminates separate feed and
return conduits

3F

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups A, B, C, D*
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 7ABCD,9EFG

Description
LBH and LBY series – copper-free
aluminum
LBH and LBY series – Corro-free™
epoxy powder coat

• NEC:
LBH 10-20 –
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
LBH 30-100
Class I, Division 1 & 2, Group D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
LBY –
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
ET –
Class I, Division 1 & 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Suffix
SA
S752

Size Ranges:
• LBH bodies – hub size 1/2" to 4"
• LBY elbows – hub size 1/2" to 11/2"

Ordering Information
Hub Size Cat. #
LBH
/2
/4

LBH10
LBH20
1
LBH30
11/4
LBH40
11/2
LBH50
2
LBH60
21/2
LBH70
3
LBH80
31/2
LBH90
4
LBH100
Hub Size Cat. #
1
3

LBY

/2
/4

LBY15
LBY25
LBY35
LBY45
LBY55

1
3

1
11/4
11/2

Standard Materials:
• LBH, LBY and ET – Feraloy® iron alloy

ET

Standard Finishes:

Hub Size

Cat. #

/4–1/2–1/2‡
3
/4–3/4–3/4‡
1–3/4–3/4‡

ET218
ET228
ET328

3

• LBH, LBY and ET – electrogalvanized and
aluminum acrylic paint

‡Largest hub is shown at
top of photo.

Dimensions
In Inches:

ET

LBY

LBY

LBH

1
11/4
11/2

LBH
Size
1
/2–3/4
1–1/4
11/2
2
2-1/2–3
3-1/2–4

ET

Size
1
/2
3
/4

a

b

29/16
213/16
33/32
33/4
41/4

2
21/4
21/2
215/16
33/8

a

b

c

d

e

f

51/16
77/8
1015/16
1021/32
155/8
239/16

219/32
313/32
41/2
425/32
51/2
611/16

4
51/4
73/32
73/32
91/2
113/4

13/16
13/4
21/2
21/2
3
4

4
7
10
10
153/4
24

23/4
4
5
5
55/8
71/8

Size
3
/4–1/2–1/2
3
/4–3/4–3/4
1–3/4–3/4

a

b

c

d

4
4
4

25/8
3
3

11/4
11/2
11/2

11/2
11/2
13/4

*See Compliances for classification of each product.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

61

3F

Condulet® Elbows and Tees
IEC Certifications

Zone 1
Zone 2

Zone 21
Zone 22

3F

FE and FT Series
Applications:
FE and FT conduit fittings are installed in
hazardous areas to:
• Act as draw-in outlets especially for
cables that are stiff due to large size or
type of insulation
• Make 90º bends in conduit systems,
allowing for a straight pull in either
direction
• Provide access to wiring for
maintenance and future system changes

Features:
• Maximum volume for bends within a
compact overall size
• Large openings to facilitate cable pulling

Certifications and
Compliances:
Type of Protection
• Ex d, DIP A21, IP67
Degree of Protection

Ordering Information:
Inspection Elbows and Tees Selection
Cat. #

Type

Entry Size (metric)

FE1
FE2
FT1
FT2

Elbow
Elbow
Tee
Tee

M20
M25
M20
M25

(F)-M20
(F)-M25
(F)-M20
(F)-M25

(F)
(F)
(F)
(F)

Dimensions (mm)

• IP67
Gas Group
• IIB
Approvals
• Ex1108U

Standard Materials:
• Body – Copper-free aluminum
• Cover – Brass

Standard Finishes:
• Natural

Options:
Description
Suffix
NPT & BSP thread sizes Consult Factory

62

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

3F

Lubricants

Certifications and Compliances:

• STL thread lubricant is used between any screw thread and its
tapped opening, on any rotating shaft – threaded or plain, and to
inhibit corrosion on any metal-to-metal joint of apparatus and
control enclosures.

• Complies with NEC 2008, Article 300.6

3F

Applications:

• HTL high temperature lubricant is used on lighting fixture threaded
joints and on threaded joints of the enclosures of any heatproducing apparatus or control.

Features:
STL thread lubricant is lithium based, antigalling and:
• Is especially effective between parts made of dissimilar metals
• Is effective and stable from –20°F to +300°F
• Maintains grounding continuity; should not be used on exposed
current-carrying parts
• Has excellent adhesion qualities; a liberal application on threaded
joints maintains raintightness and inhibits corrosion
HTL is a high temperature, anti-seize, conductive thread lubricant:
• Effective and stable from –70°F to +1800°F
• Prevents seizure, galling, rust, galvanic action
• Maintains grounding continuity; should not be used on exposed
current-carrying parts
• Effective between parts made of dissimilar metals

STL Thread Lubricant

HTL High Temperature Thread Lubricant

Net Wt.

Cat. #

Net Wt.

13/ 4 oz. (tube)
8 oz. (can)

STL2
STL8

4 oz. (tube)
HTL4
MSDS Sheets are available at www.crouse-hinds.com

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Cat. #

Copyright© 2013 Eaton’s Crouse-Hinds Business

63

3F

3F

3F

64

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4F

Cable Glands and Cable Accessories
Hazardous and Non-hazardous

Page No.

Application

see page 66

Description
Cable Glands - Accessories
A Series
B Series
D Series
E Series
Breathers and Drains

Cable Glands - International Standards
Quick Selection Guide

see pages 67–70

Flameproof and Increased Safety
ADE 1F
ADE 4F
ADE 6F
ADE 6FC
ADE 1FC
Ex - e
Ex - i
Trumpet
Enlargement and Multiple

see
see
see
see
see
see
see
see
see

page
page
page
page
page
page
page
page
page

71
72
73
74
75
76
77
78
79

Conduit
LCC, LCCF Series

see page 104

Grounding Conductor
TGC Series

see page 105

Cable/Conduit Sealing Devices
Thru-Wall Barrier®
TW Series

ADE 4I

see page 96
see page 100
see page 101
see page 102
see page 103

Cable Tray Clamps

Industrial
see page 80

Cable Glands - North American
Standards
Quick Selection Guide

Page No.

see pages 106–107

Link Seal – For Conduit
Environmental Seal
Fire Seal

see pages 112–113
see pages 114–115

see pages 67–70

Explosionproof
Terminator™ II TMCX
TMCX
ADE 6FC
ADE 1FC
CGBS
EBY

see pages 81–82
see page 83
see page 84
see page 85
see page 86
see page 86

General Purpose
TMC
TECK
CGB
CGD
CGE
CGB1013
CGFP
NCG
NCGB

see page 87
see page 88
see pages 89–90
see page 91
see page 92
see page 93
see page 94
see page 95
see page 95

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

65

4F

Description

4F

Cable Glands and Cable Accessories

4F

Application and Selection
Applications:

Considerations for Selection:

Cable glands and cord fittings:

• Selection of the proper cable gland involves consideration of the
type of cable to be installed and the environment that will surround
the cable after installation.

• Provide means for passing a cord, cable (armored or unarmored)
or flexible conduit into an enclosure, through a bulkhead or into a
rigid conduit
• Form a mechanical grip and water and/or oil-resistant seal for cord
and unarmored or jacketed armored, round cables
• Form a non-slip connection or termination for flexible cord, cable
(armored or unarmored), or flexible conduit
• Provide grounding continuity for cable armor and flexible conduit
Cable glands with sealing fitting or epoxy are installed to:
• Provide means for passing armored, metal clad, jacketed or
unjacketed and unarmored cables through a bulkhead or
enclosure in hazardous areas. These fittings are suitable for use in
Class I, Groups C, D locations only when Chico® A sealing
compound or TSC epoxy (TMCX) is used to make the seal in the
fitting*
• Form a mechanical grip and water and/or oil-resistant termination
• Provide ground continuity of cable armor and flexible conduit
TMC (non-hazardous) and TMCX (hazardous) fittings are designed
for use with Type MC jacketed steel or aluminum metal clad cables
with interlocked or corrugated armor and Type TC tray cable (TMCX).

• A proper matching of the cable and its gland is necessary to
prevent physical damage to the cable when installed. Some types
of cable glands depend on gripping methods (set screws, etc.)
which may lead to damage of the cable outer covering. Eaton's
Crouse-Hinds cable glands and cord fittings utilize compression of
split lead or tapered neoprene bushings to provide high gripping
strength for adequate cable support and strain relief without
damage to the cable sheath.
• Compression of bushing provides a strong electrical bond that
assures grounding continuity.
• Compression of a tapered neoprene bushing assures the
watertight integrity of Eaton's Crouse-Hinds cable glands.
Additional watertightness, to prevent water seepage into the fitting
body, can be obtained by use of a potting head filled with a hot
pouring compound.
• To meet National Electrical Code requirements for electrical
installations in hazardous atmospheres, a sealing fitting may be
required in conjunction with the cable or cord fitting.
*With specific cords and cables when installed in accordance with NEC/CEC requirements.

LCC cable tray conduit clamps are used for installation on cable tray
side rails with inside flanges (requiring inside tray mounting) and
outside flanges; LCCF clamps are for use exclusively on inside
flanges. LCC/LCCF series cable tray conduit clamps are installed to:
• Provide a means of clamping metal conduit (rigid steel or
aluminum, IMC and EMT) to cable tray for the exit of power and/or
control cables from tray
• Provide a means to firmly bond exiting conduit to cable tray for
best grounding continuity
TW Series THRU-WALL BARRIER® cable/conduit sealing devices are
installed to:
• Seal cables or conduits penetrating fire rated walls, ceilings, or
floors
• Restrict entrance of water and dust and contain treated air
• Provide a seal for cable/conduit penetrations through steel,
masonry or concrete; to restrict the entrance of contaminants
through cable/conduit penetrations into clean areas
TGC cable tray grounding conductor clamp provides a means for
securely attaching a grounding conductor to cable tray to provide
grounding continuity for the entire tray system. TGC cable tray
grounding conductor clamps provide a reliable method for carrying
ground fault current for equipment protection. TGC clamp may be
installed on most types of cable trays – with inside or outside
flanges.

66

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4F

Global Cable Glands
Quick Selection Guide - International Standards

ILLUSTRATION

CABLE
TYPE

GLAND
TYPE

STANDARD
MATERIAL

CERTIFICATION

PROTECTION
TYPE

ADE 1F
(see
page 71)

Non-armoured,
armoured and tray
Non-armoured Nickel-plated brass
cable (does not
terminate the armour)

Flameproof &
Increased Safety

ADE 4F
(see
page 72)

SWA, SWB, STA,
braided marine
shipboard and lead
sheathed (with
addition of earthing
washer)

Armoured

Nickel-plated brass

Flameproof &
Increased Safety

ADE 6F
(see
page 73)

SWA, SWB, STA and
braided marine
shipboard

Armoured

Nickel-plated brass

Flameproof &
Increased Safety

ADE 6FC
(see
page 74)

SWA, SWB, STA,
braided marine
shipboard and lead
sheathed (with
addition of earthing
washer)

Armoured
barrier

Nickel-plated brass

Flameproof &
Increased Safety

ADE 1FC
(see
page 75)

Non-armoured,
armoured and tray
Non-armoured
Nickel-plated brass
cable (does not
barrier
terminate the armour)

Flameproof &
Increased Safety

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

4F

CABLE
GLAND

Copyright© 2013 Eaton’s Crouse-Hinds Business

67

Global Cable Glands

4F

4F

Quick Selection Guide - International Standards
CABLE
GLAND

CABLE
TYPE

GLAND
TYPE

STANDARD
MATERIAL

Ex - e
(see
page 76)

Nonarmoured

Non-armoured

Polyamide

Increased Safety

Ex - i
(see
page 77)

Nonarmoured

Non-armoured

Polyamide

Increased Safety

Trumpet
(see
page 78)

Nonarmoured

Non-armoured

Polyamide

Increased Safety

Enlargement
and Multiple
(see
page 79)

Nonarmoured

Non-armoured

Polyamide

Increased Safety

ADE 4I
(see
page 80)

SWA, SWB,
STA, braided
marine
shipboard
Armoured
and lead
sheathed
(with addition
of earthing
washer)

Nickel-plated brass

Industrial

68

ILLUSTRATION

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

CERTIFICATION

Copyright© 2013 Eaton’s Crouse-Hinds Business

PROTECTION
TYPE

4F

Global Cable Glands
Quick Selection Guide - North American Standards
CABLE
TYPE

GLAND
TYPE

Metal-clad, TECK
(interlocked and
continuously welded
corrugated armoured),
unarmoured, and tray
cable

Armoured
barrier, nonarmoured
barrier, and
TECK
armoured

TMCX
(see
page 83)

Metal-clad with
interlocked or
continuously welded
corrugated, TECK
armoured, non-armoured
and tray cable

Armoured
barrier and
non-armoured
barrier

Aluminum

Explosionproof

ADE 1FC
(see
page 85)

Non-armoured,
armoured and tray
cable (does not
terminate the armour)

Non-armoured
barrier

Nickel-plated
brass

Flameproof &
Increased
Safety

ADE 6FC
(see
page 84)

SWA, SWB, STA,
braided marine
shipboard and lead
sheathed (with addition
of earthing washer)

Armoured
barrier

Nickel-plated
brass

Flameproof &
Increased
Safety

CGBS
(see
page 86)

Non-armoured
and tray cable

Portable cord
connector

Body: steel
Gland nut:
aluminum

Explosionproof

EBY
(see
page 86)

Non-armoured

Portable cord
connector

Aluminum

Explosionproof

TMC
(see
page 87)

Metal-clad with
interlocked or
continuously welded
Armoured or
non-armoured
corrugated, TECK
armoured, non-armoured
and tray cable

Aluminum

General
Purpose

TECK
(see
page 88)

TECK armoured

Armoured

Aluminum

General
Purpose

CGB
(see
pages 89–90)

Non-armoured
and tray cable

Non-armoured

Body steel
Form A-D steel
Form E-F iron

General
Purpose

ILLUSTRATION

B

F

D

G

A

C

E

Terminator™
II TMCX
X (see
pages 81–82)

www.crouse-hinds.com

US: 1-866-764-5454

STANDARD
MATERIAL

Aluminum

CAN: 1-800-265-0502

CERTIFICATION

PROTECTION
TYPE

Explosionproof

Copyright© 2013 Eaton’s Crouse-Hinds Business

69

4F

CABLE
GLAND

4F

Global Cable Glands

4F

Quick Selection Guide - North American Standards
CABLE
GLAND

CABLE
TYPE

GLAND
TYPE

STANDARD
MATERIAL

CGD
(see
page 91)

Non-armoured
and tray cable

Non-armoured

Body: iron
Gland nut: steel

General Purpose

CGE
(see
page 92)

Non-armoured
and tray cable

Non-armoured

Body: iron
Gland nut: steel

General Purpose

CGB1013
(see
page 93)

Non-armoured
and tray cable

Portable cord
connector

Body: steel
Gland nut:
aluminum

General Purpose

CGFP
(see
page 94)

Non-armoured
and tray cable

Non-armoured

Form B-C: steel
Form D-G: iron

General Purpose

NCG
(see
page 95)

Non-armoured
and tray cable

Non-armoured

Polyamide

General Purpose

Non-armoured
and tray cable

Non-armoured

Thermoplastic
polyester

General Purpose

ILLUSTRATION

CERTIFICATION

PROTECTION
TYPE

NCGB

NCGB
(see
page 95)

70

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

ADE 1F

CEPEL
GOST-R
NEPSI
NEMA 4X and IP68

ATEX
IECEx
cULus Listed for Class I, Zone 2
cULus Marine Listed for Class I, Zone 2

International Standards Flameproof and Increased Safety

4F

4F

Gland Type:
Non-armoured

Cable Type:
Non-armoured, armoured and tray cable (does not terminate the
armour)

Certifications and Compliances:
• ATEX LCIE 97 ATEX 6008X – Exd IIC/Exe II/Ex tD /Ex II 2 GD
• IECEx LCI 05.0004X

Features:

• cULus Listed for Class I Zone 2 AEx e II/Ex e II E310130

• Standard material is nickel-plated brass for superior corrosion
resistance

• cULus Marine Listed for Class I Zone 2 AEx e II/Ex e II E314047

• Provides a flameproof and weatherproof seal on the outer sheath
of the cable

• NEMA 4X and IP68
• CEPEL cepel-EX-558/05X
• GOST-R POCC FR.B02011

• Standard neoprene seal suitable for use in operating temperatures
ATEX (-60°C to 100°C), IECEx and cULus (-40°C to 100°C)

• NEPSI N° GYJ071336U & GYJ071337U

• Available with optional silicone seal for extreme temperatures
• Available with metric or NPT threads
• See pages 96–103 for related accessories

ORDERING EXAMPLE:
CAP81640 4 KX

Gland Type

Options

SELECTION TABLE
Entry Thread Size ‘A’
Gland
Size
4
4
5
4
5
6
5
6
7
7
8
8
9
9
10
11
12
12
13
14
15
16

Metric
Size
M12
M16
M16
M20
M20
M20
M25
M25
M25
M32
M32
M40
M40
M50
M50
M63
M63
M75
M75
M90
M90
M110

Metric
Catalog #
CAP816404
CAP816594
CAP816504
CAP816674
CAP816694
CAP816604
CAP816774
CAP816794
CAP816704
CAP816894
CAP816804
CAP816994
CAP816904
CAP817094
CAP817004
CAP817294
CAP817204
CAP817394
CAP817304
CAP817594
CAP817504
CAP817794

NPT
Size
1
/4"
3
/8"
1
/2"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/2"
11/2"
2"
2"
21/2"
21/2"
3"
3"
31/2"

NPT
Catalog #

CAP818404
CAP818594
CAP818694
CAP818674
CAP818694
CAP818604
CAP818774
CAP818794
CAP818704
CAP818894
CAP818804
CAP818994
CAP818904
CAP819094
CAP819004
CAP819294
CAP819204
CAP819494
CAP819404
CAP819594
CAP819504
CAP819604

www.crouse-hinds.com

Thread
Length ‘B’
Metric
(NPT)
15 (12.0)
15 (12.0)
15 (12.0)
15 (20.2)
15 (20.2)
15 (20.2)
15 (20.2)
15 (20.2)
15 (20.2)
15 (25.3)
15 (25.3)
15 (26.0)
15 (26.0)
15 (26.5)
15 (26.5)
17 (27.2)
17 (27.2)
18 (40.5)
18 (40.5)
22 (42.0)
22 (42.0)
22 (43.2)

US: 1-866-764-5454

Cable Acceptance
Outer Sheath‘E’
Min

Max

4.0
4.0
6.0
4.0
6.0
8.5
6.0
8.5
12.0
12.0
16.0
16.0
21.0
21.0
27.0
33.0
40.0
40.0
47.0
54.0
63.0
72.0

8.0
8.5
12.0
8.5
12.0
16.0
12.0
16.0
21.0
21.0
27.5
27.5
34.0
34.0
41.0
48.0
56.0
56.0
65.0
74.0
78.0
92.0

CAN: 1-800-265-0502

OPTIONS (replace last digit with option number):
9
8
7
5

Stainless steel (316L)
Bronze
Aluminum
Silicone sealing ring with temperature range of
-70°C to 220°C
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud

Gland
Length ‘F’
(less entry)
20
20
22
20
22
25
22
25
27
27
34
34
36
36
39
41
43
43
49
56
61
62

Hexagon Dimensions
Across
Flats
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

Across
Corners ‘G’
16.5
20.9
20.9
26.4
26.4
26.4
33
33
33
39.6
45.1
48.4
52.8
60.5
60.5
73.7
79.2
88
93.5
104.5
121
132

Copyright© 2013 Eaton’s Crouse-Hinds Business

71

ADE 4F

4F

ATEX
IECEx
cULus Listed for Class I, Zone 2
cULus Marine Listed for Class I,
Zone 1

4F

International Standards Flameproof and Increased Safety

CEPEL
GOST-R
NEPSI
NEMA 4X and IP68

Gland Type:
Armoured

Cable Type:
Steel wire armoured, steel wire braided, steel tape armoured, braided
marine shipboard and lead sheathed (with addition of earthing
washer)

Certifications and Compliances:
• ATEX LCIE 97 ATEX 6008X – Exd IIC/Exe II/Ex tD/Ex II 2 GD
• IECEx LCI 05.0004X
• cULus listed for Class I, Zone 2 AEx e II/Ex e II E310130
• cULus Marine listed for Class I, Zone 1 AEx e II/Ex e II E314047
• NEMA 4X and IP68
• CEPEL cepel-EX-559/05X
• GOST-R POCC FR.B02011
• NEPSI N° GYJ071336U & GYJ071337U

Features:
• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping and bonding with no reversible components for
easy installation, minimizing error
• Provides flameproof seal on inner jacket and weatherproof seal on
outer sheath of cable
• Optional earthing washer for use with lead sheathed cable
(see page 97)
• Standard neoprene seal suitable for use in operating temperatures
ATEX (-60°C to 100°C), IECEx and cULus (-40°C to 100°C)
• Available with optional silicone seal for extreme temperatures
• Available with metric or NPT threads
• See pages 96–103 for related accessories

OPTIONS (replace last digit with option number):

ORDERING EXAMPLE:

9
8
7
5

Stainless steel (316L)
Bronze
Aluminum
Silicone sealing ring with temperature range of
-70°C to 220°C
K1 Includes locknut and fiber washer
K2 Includes locknut, fiber washer, earth tag, and
shroud

CAP84640 4 KX

Gland Type

Options

SELECTION TABLE
Entry Thread Size ‘A’

Gland Metric
Size
Size
5
M12
5
M16
6
M16
5
M20
6
M20
7
M20
6
M25
7
M25
8
M25
8
M32
9
M32
9
M40
10
M40
10
M50
11
M50
12
M63
13
M63
13
M75
14
M75
15
M90
16
M90
16
M90
17
M110

Metric
Catalog #
CAP846404
CAP846594
CAP846504
CAP846674
CAP846694
CAP846604
CAP846774
CAP846794
CAP846704
CAP846894
CAP846804
CAP846994
CAP846904
CAP847094
CAP847004
CAP847294
CAP847204
CAP847394
CAP847304
CAP847794
CAP847504
CAP847574
CAP847794

Thread
Length ‘B’
Metric
NPT
(NPT)
Size NPT Catalog #
1
/4" CAP848404
15 (12.0)
3
/8" CAP848594
15 (12.0)
3
/8" CAP848504
15 (12.0)
1
/2" CAP848674
15 (20.2)
1
/2" CAP848694
15 (20.2)
1
/2" CAP848604
15 (20.2)
3
/4" CAP848774
15 (20.2)
3
/4" CAP848794
15 (20.2)
3
/4" CAP848704
15 (20.2)
1" CAP848894
15 (25.3)
1" CAP848804
15 (25.3)
11/4" CAP848994
15 (26.0)
11/4" CAP848904
15 (26.0)
11/2" CAP849094
15 (26.5)
11/2" CAP849004
15 (26.5)
2" CAP849294
17 (27.2)
2" CAP849204
17 (27.2)
21/2" CAP849494
18 (40.5)
18 (40.5)
21/2" CAP849404
3" CAP849594
22 (42.0)
3" CAP849504
22 (42.0)
31/2" CAP849604
N/A (43.2)
4" CAP849704
22 (44.5)

Cable Acceptance
Inner Sheath Outer Sheath
‘D’
‘E’
Min

Max

Min

Max

4.0
4.0
6.0
4.0
6.0
8.5
6.0
8.5
12.0
12.0
16.0
16.0
21.0
21.0
27.0
27.0
33.0
40.0
47.0
54.0
63.0
63.0
72.0

8.0
8.5
12.0
8.5
12.0
16.0
12.0
16.0
20.5
21.0
27.5
27.5
34.0
34.0
41.0
41.0
48.0
56.0
65.0
74.0
82.0
82.0
92.0

6.0
6.0
8.5
6.0
8.5
12.0
8.5
12.0
16.0
16.0
21.0
21.0
27.0
27.0
33.0
33.0
47.0
47.0
54.0
63.0
72.0
72.0*
85.0

12.0
12.0
16.0
12.0
16.0
21.0
16.0
21.0
27.5
27.5
34.0
34.0
41.0
41.0
48.0
48.0
56.0
65.0
74.0
83.0
93.0
93.0*
107.0

Hexagon
Dimensions
Gland
Across
Length
Armour ‘F’ (less Across Corners
entry)
Flats
‘G’
(max)
0.9
36
–
20.9
0.9
36
–
20.9
1.25
42
–
26.4
0.9
36
–
26.4
1.25
42
–
26.4
1.25
46
–
33.0
1.25
42
–
33.0
1.25
46
–
33.0
1.6
56
–
45.1
1.6
56
–
45.1
1.6
63
–
52.8
1.6
63
–
52.8
2.0
68
–
60.5
2.0
68
–
60.5
2.5
74
–
70.4
2.5
77
–
79.2
2.5
85
–
93.5
2.5
85
–
93.5
2.5
92
–
104.5
3.15
104
–
121.0
3.15
108
–
132.0
3.15
108
–
132.0
3.15
115
–
148.5

All dimensions in millimeters unless otherwise noted * CAP849604 “outer sheath” min: 85 max: 107.

72

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

ADE 6F

ATEX
IECEx
cULus Listed for Class I, Zone 2
cULus Marine Listed for Class I,
Zone 2

International Standards Flameproof and Increased Safety

CEPEL
GOST-R
NEPSI
NEMA 4X and IP68

4F

4F

Gland Type:
Armoured

Cable Type:
Steel wire armoured, steel wire braided, steel tape armoured and
braided marine shipboard

Certifications and Compliances:
• ATEX LCIE 97 6008X - Exd IIC / Exe II / Ex tD / Ex II 2GD

Features:

• IECEx LCI 05.0004X

• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping and bonding with no reversible components for
easy installation, minimizing error
• Provides fully inspectable inner seal after installation
• Flameproof diaphragm seal on inner jacket does not damage
cables exhibiting “cold-flow”; weatherproof seal on outer
sheath of cable
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
ATEX (-60°C to 100°C), IECEx and cULus (-40°C to 100°C)
• Available with metric or NPT threads
• See pages 96–103 for related accessories

• cULus Listed for Class I, Zone 2 AEx e II / Ex e II E310130
• cULus Marine Listed for Class I, Zone 2 AEx e II / Ex e II E314047
• NEMA 4X and IP68
• CEPEL
• GOST-R
• NEPSI

SELECTION TABLE
Entry Thread Size ‘A’
Gland
Size
5
5
6
7
7
8
8
9
9
10
10
11

Metric
Size
M16
M20
M20
M20
M25
M25
M32
M32
M40
M40
M50
M50

Metric
Catalog #
CAP965594
CAP965674
CAP965694
CAP965604
CAP965794
CAP965704
CAP965894
CAP965804
CAP965994
CAP965904
CAP966094
CAP966004

NPT
Size
3
/8"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/ 2"
2"

NPT
Catalog #
CAP967594
CAP967674
CAP967694
CAP967604
CAP967794
CAP967704
CAP967894
CAP967804
CAP967994
CAP967904
CAP968094
CAP968294

Thread
Length ‘B’
Metric
(NPT)
15 (12.0)
15 (20.2)
15 (20.2)
15 (20.2)
15 (20.2)
15 (20.2)
15 (25.3)
15 (25.3)
15 (26.0)
15 (26.0)
16 (26.5)
16 (27.2)

Cable Acceptance
Inner
Outer
Sheath ‘D’ Sheath ‘E’
Min
3.0
3.0
6.5
9.0
9.0
12.0
12.0
17.5
17.5
23.0
23.0
28.5

Max
7.5
7.5
11.0
14.5
14.5
19.5
19.5
26.0
26.0
33.0
33.0
41.0

Min
6.0
6.0
8.5
12.0
12.0
16.0
16.0
21.0
21.0
27.0
27.0
33.0

Max
12.0
12.0
16.0
21.0
21.0
27.5
27.5
34.0
34.0
41.0
41.0
48.0

Armour
(max)
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5

Gland
Length
‘F’ (less
entry)
46.0
46.0
53.0
59.0
59.0
74.5
74.5
83.5
83.5
92.0
92.0
104.0

Hexagon
Dimensions
Across
Across
Corners
Flats
‘G’
–
20.9
–
26.4
–
26.4
–
33.0
–
33.0
–
45.1
–
45.1
–
52.8
–
52.8
–
60.5
–
60.5
–
70.4

Larger sizes available in ADE 4F design, see page 72.
All dimensions in millimeters unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

73

4F

ADE 6FC

4F

International Standards Flameproof and Increased Safety

ATEX
IECEx
cULus Listed for Class I, Zone 2
cULus Marine Listed for Class I, Div. 1

CEPEL
GOST-R
NEMA 4X and IP68

Gland Type:
Armoured barrier

Cable Type:
Steel wire armoured, steel wire braided, steel tape armoured,
braided marine shipboard and lead sheathed (with addition of
earthing washer)

Features

Certifications and Compliances:

• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping with no reversible components for easy
installation, minimizing error
• Provides explosionproof compound seal (denoted by red back nut)
on conductors and weatherproof seal on outer sheath of cable
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
-60°C (-25°C UL) to 80°C
• Available with metric or NPT threads
• See pages 96–103 for related accessories
ORDERING EXAMPLE:
OPTIONS (replace last digit with option number):

•
•
•
•
•
•
•
•
•

ATEX LCIE 97 ATEX 6008X - Exd IIC/Exe II/Ex tD/Ex II 2 GD
IECEx LCI 05.0004X
cULus Listed for Class I, Zone 2 AEx de II/Ex de II
cULus Marine Listed for Class I, Division 1, Groups A, B, C, D
NEMA 4X and IP68
CEPEL-EX-558/05X
GOST-R POCC FR Bo2011
NEPSI N° GYJ071336U & GYJ071337U
ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• DNV N° E-10892
• Lloyds

9
8
7
K1
K2

CAP96959 4 KX

SELECTION TABLE

Gland Type

Entry Thread Size ‘A’

Gland Metric
Size
Size
5
M16

Metric
Catalog #
CAP969594

Options

Cable Acceptance
Inner Sheath
Outer
and Cores
Sheath ‘E’
Max
Max
Over Inner
Max
Cores Sheath No. of
'C'
'D'
Cores Min Max

Hexagon
Dimensions

NPT
Size
3
/8"

Thread
Length
‘B’
NPT
Metric
Catalog #
(NPT)
CAP974594 15 (12.0)

/2"

CAP971674 15 (20.2)

6.5
6.5

7.5
7.5

6.0
6.0

6.0
6.0

12.0
12.0

0.9

46.0

–

26.4

/2"

CAP971694 15 (20.2)

9.5

11.0

6.0

8.5

16.0

1.25

53.0

–

26.4

/2"

CAP971604 15 (20.2)

12.0

14.5

10.0

12.0

21.0

1.25

59.0

–

33.0

/4"

CAP971794 15 (20.5)

12.0

14.5

10.0

12.0

21.0

1.25

59.0

–

33.0

Gland
Length
Across
Armour ‘F’ (less Across Corners
entry)
(max)
Flats
‘G’
0.9
46.0
–
20.9

5

M20

CAP969674

1

6

M20

CAP969694

1

7

M20

CAP969604

1

7

M25

CAP969794

3

8

M25

CAP969704

3

/4"

CAP971704 15 (20.5)

17.0

19.5

21.0

16.0

27.5

1.6

74.5

–

45.1

8

M32

CAP969894

1"

CAP971894 15 (25.3)

17.0

19.5

21.0

16.0

27.5

1.6

74.5

–

45.1

9

M32

CAP969804

1"

CAP971804 15 (25.3)

23.0

28.0

42.0

21.0

34.0

1.6

83.5

–

52.8

9

M40

CAP969994

11/4"

CAP971994 15 (26.0)

23.0

28.0

42.0

21.0

34.0

1.6

83.5

–

52.8

10

M40

CAP969904

11/4"

CAP971904 15 (26.0)

29.0

33.0

60.0

27.0

41.0

2.0

92.0

–

60.5

10

M50

CAP970094

11/2"

CAP972094 16 (26.5)

29.0

33.0

60.0

27.0

41.0

2.0

92.0

–

60.5

11

M50

CAP970004

11/2"

CAP972004 16 (27.2)

36.5

41.0

80.0

33.0

48.0

2.5

104.0

–

70.4

12

M63

CAP970294

2"

CAP972274 17 (29.2)

43.0

48.0

100.0

40.0

56.0

2.5

108.0

–

79.2

13

M63

CAP970204

2"

CAP972204 17 (29.2)

50.0

56.0

100.0

46.0

65.0

2.5

118.0

–

93.5

13

M75

CAP970394

21/2"

CAP972494 18 (42.5)

50.0

56.0

100.0

46.0

65.0

2.5

118.0

–

93.5

14

M75

CAP970304

21/2"

CAP972404 18 (42.5)

59.0

65.0

120.0

54.0

74.0

2.5

124.0

–

104.5

14

–

–

3"

CAP972574

15

M90

CAP970594

3"

CAP972594 22 (44.0)

15

–

–

31/2"

16

M90

CAP970504

3"

16

–

–

31/2"

17

M110

CAP970794

4"

CAP972694

(44)
(45.2)

CAP972504 22 (44.0)
CAP972604

(45.2)

CAP972704 22 (46.5)

59.0

65.0

120.0

54.0

74.0

2.5

124.0

–

104.5

66.0

73.0

140.0

63.0

83.0

3.15

133.0

–

121.0

66.0

73.0

140.0

63.0

83.0

3.15

133.0

–

121.0

75.0

82.0

140.0

72.0

93.0

3.15

137.0

–

132.0

75.0

82.0**

140.0

72.0

93.0

3.15

137.0

–

132.0

85.0

92.0**

200.0

85.0

107.0

3.15

142.0

–

148.5

All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your field sales representative for amended UL marine range.

74

Stainless steel (316L)
Bronze
Aluminum
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

CEPEL
GOST-R
NEMA 4X and IP68

ATEX
IECEx
cULus Listed for Class I, Zone 2
UL Marine Listed for Class I, Div. 2

ADE 1FC
International Standards Flameproof and Increased Safety

4F

4F

Gland Type:
Non-armoured barrier

Cable Type:
Non-armoured, armoured and tray cable (does not terminate the
armour)

Certifications and Compliances:

Features:

•
•
•
•
•
•
•
•
•
•

LCIE 97 ATEX 6008X II GD - Exd IIC/Exe II/Ex tD
IECEx LCI 05.0004X Ex c e IIC/Ex c e II/Ex tD
cULus Listed for Class I, Zone 2 AEx de II/Ex de II
UL Marine Listed for Class I, Division 2, Groups A, B, C, D
NEMA 4X and IP68
CEPEL EX-558/05X
GOST-R POCC FR.B03126
NEPSI N° GYJ071336U & GYJ071337U
DNV N° E-10892
ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• Lloyds

• Standard material is nickel-plated brass for superior corrosion
resistance
• Provides a flameproof and weatherproof seal on outer sheath of
cable
• Provides explosionproof compound seal (denoted by red back nut)
on conductors
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
-60°C (-25°C UL) to 80°C
• Available with metric or NPT threads
• See pages 96–103 for related accessories

ORDERING EXAMPLE:
CAP01959 4 KX
Gland Type

Options

OPTIONS (replace last digit with option number):
9
8
7
K1
K2

Stainless steel (316L)
Bronze
Aluminum
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud

SELECTION TABLE
Entry Thread Size ‘A’
Gland
Size
4
4
5
6
6
7
7
8
8
9
9
10
10
11
12
12
13
13
14
14
15
15
16

Metric
Size
M16
M20
M20
M20
M25
M25
M32
M32
M40
M40
M50
M50
M63
M63
M63
–
M75
–
M90
–
M90
–
M110

Metric
Catalog #
CAP019594
CAP019674
CAP019694
CAP019604
CAP019794
CAP019704
CAP019894
CAP019804
CAP019994
CAP019904
CAP019094
CAP019004
CAP019204
CAP019294
CAP019274
–
CAP019304
–
CAP010594
–
CAP010504
–
CAP010794

NPT
Size
3
/8"

NPT
Catalog #
CAP011594

/2"
/2"
1
/2"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/2"
2"
–
2"
2"
21/2"
21/2"
3"
3"
31/2"
3"
31/2"
4"

CAP011674
CAP011694
CAP011604
CAP011794
CAP011704
CAP011894
CAP011804
CAP011994
CAP011904
CAP011094
CAP011004
–
CAP011294
CAP011204
CAP011494
CAP011404
CAP012504
CAP012574
CAP012604
CAP012594
CAP012694
CAP012704

1
1

Thread
Cable Acceptance
Length ‘B’ Outer Sheath ‘E’
Metric
Min
Max
(NPT)
15 (12.0)
4.0
7.5
15 (22.2)
4.0
7.5
15 (22.2)
6.5
11.0
15 (22.2)
9.0
14.5
15 (22.5)
9.0
14.5
15 (22.5)
12.0
19.5
15 (27.3)
12.0
19.5
15 (27.3)
17.5
26.0
15 (28.0)
17.5
26.0
15 (28.0)
23.0
33.0
16 (28.5)
23.0
33.0
16 (29.2)
28.5
41.0
16
28.5
41.0
17 (29.2)
43.0
48.0
17 (29.2)
50.0
56.0
42.5
50.0
56.0
18 (42.5)
59.0
65.0
44
59.0
65.0
22 (44.0)
66.0
73.0
45.2
66.0
73.0
22 (44.0)
75.0
82.0
45.2
75.0
82.0**
22 (46.5)
85.0
92.0**

Hexagon
Dimensions
Gland
Across
Max No. Length ‘F’ Across
Cores (less entry) Flats Corners ‘G’
20.9
6.0
46.0
–
–
6.0
46.0
26.4
–
6.0
53.0
26.4
–
10.0
59.0
33.0
–
10.0
59.0
33.0
–
21.0
74.5
45.1
–
21.0
74.5
45.1
–
42.0
83.5
52.8
–
42.0
83.5
52.8
–
60.0
92.0
60.5
–
60.0
92.0
60.5
–
80.0
104.0
70.4
–
80.0
–
73.7
–
100.0
98.0
70.4
–
100.0
103.0
79.2
–
100.0
103.0
79.2
–
120.0
111.0
93.5
–
120.0
111.0
93.5
–
140.0
120.0
104.5
–
140.0
120.0
104.5
–
140.0
125.0
121.0
–
140.0
125.0
121.0
–
200.0
128.0
132.0

All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your field sales representative for amended UL marine range.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

75

Ex-e

4F

4F

International Standards Flameproof and Increased Safety

IP66

Sizes M12-M16: PTB 99 ATEX
3101 X
Sizes M20-M63: PTB 99 ATEX
3128 X
IECEx

Gland Type:
Non-armoured

Cable Type:
Non-armoured

Certifications and Compliances:
• Sizes M12-M16: PTB 99 ATEX 3101 X
Sizes M20-M63: PTB 99 ATEX 3128 X
Ex II 2 G Ex e II/Ex II 2 D Ex tD A21
• IECEx PTB 05.0004X

Features:

• IP66

• Standard material is high-impact resistant polyamide
• Forms weatherproof seal on outer sheath of cable
• Standard silicone seal suitable for use in operating temperatures
-55° to 70°C (M12 and M16 for use in operating temperatures
-20° to 70°C)
• Available with optional silicone seal for extreme temperatures
• Available with metric threads
• See page 101 for related accessories

SELECTION TABLE - SHORT THREAD
Entry Thread Size ‘A’
Gland Size Metric Size
12
M12
16
M16
20
M20
25
M25
32
M32

Metric Catalog #
GHG 960 1955 R 0001
GHG 960 1955 R 0002
GHG 960 1955 R 0003
GHG 960 1955 R 0004
GHG 960 1955 R 0005

Thread
Length ‘B’
Metric
8.0
8.0
8.0
8.0
10.0

Cable Acceptance
Outer Sheath ‘E’
Min
Max
4.0
7.0
5.5
10.0
5.5
13.0
8.0
17.0
12.0
21.0

Hexagon Dimensions
Gland
Length ‘F’
(less entry) Across Flats Across Corners ‘G’
19.3
15.0
16.5
23.0
20.0
22.0
25.0
24.0
26.4
29.5
29.0
31.9
35.5
36.0
39.6

Cable Acceptance

Gland
Length ‘F’
(less entry)

SELECTION TABLE - LONG THREAD
Entry Thread Size ‘A’
Gland Size Metric Size
12
M12
16
M16
20
M20
M25
25
32
M32
40
M40
50
M50
63
M63

Metric Catalog #
GHG 960 1955 R 0021
GHG 960 1955 R 0022
GHG 960 1955 R 0023
GHG 960 1955 R 0024
GHG 960 1955 R 0025
GHG 960 1955 R 0026
GHG 960 1955 R 0027
GHG 960 1955 R 0028

Thread
Length ‘B’
Metric
8.0
8.0
8.0
8.0
10.0
15.0
16.0
16.0

Outer Sheath ‘E’
Min
4.0
5.5
5.5
8.0
12.0
17.0
22.0
27.0

Max
7.0
10.0
13.0
27.0
21.0
28.0
35.0
48.0

19.3
23.0
25.0
29.5
35.5
39.5
44.0
47.0

Hexagon Dimensions
Across Flats Across Corners ‘G’
15.0
16.5
20.0
22.0
24.0
26.4
29.0
31.9
36.0
39.6
46.0
50.6
55.0
60.5
68.0
74.8

All dimensions in millimeters unless otherwise noted.

76

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Ex-i
International Standards Flameproof and Increased Safety

IP66

Sizes M12-M16: PTB 99 ATEX
3101 X
Sizes M20-M63: PTB 99 ATEX
3128 X
IECEx

4F

4F

Gland Type:
Non-armoured

Cable Type:
Non-armoured

Certifications and Compliances:
• Sizes M12-M16: PTB 99 ATEX 3101 X
Sizes M20-M63: PTB 99 ATEX 3128 X
Ex II 2 G Ex e II/Ex II 2 D Ex tD A21
• IECEx PTB 05.0004X

Features:

• IP66

• Standard material is high-impact resistant polyamide (gland nut is
blue for intrinsically safe circuits)
• Forms weatherproof seal on outer sheath of cable
• Standard silicone seal suitable for use in operating temperatures
-55° to 70°C (M12 and M16 for use in operating temperatures
-20° to 70°C)
• Available with metric threads
• See page 101 for related accessories

SELECTION TABLE – SHORT THREAD
Entry Thread Size ‘A’
Gland Size Metric Size
12
M12
16
M16
20
M20
25
M25
32
M32

Metric Catalog #
GHG 960 1955 R 0101
GHG 960 1955 R 0102
GHG 960 1955 R 0103
GHG 960 1955 R 0104
GHG 960 1955 R 0105

Thread
Length ‘B’
Metric
8.0
8.0
8.0
8.0
10.0

Cable Acceptance
Outer Sheath ‘E’
Min
Max
4.0
7.0
5.5
10.0
5.5
13.0
8.0
17.0
12.0
21.0

Hexagon Dimensions

Gland
Length ‘F’
(less entry)

Across Flats

Across Corners ‘G’

19.3
23.0
25.0
29.5
35.5

15.0
20.0
24.0
29.0
36.0

16.5
22.0
26.4
31.9
39.6

SELECTION TABLE – LONG THREAD
Entry Thread Size ‘A’
Gland Size Metric Size
12
M12
16
M16
20
M20
25
M25
32
M32
40
M40
50
M50
63
M63

Metric Catalog #
GHG 960 1955 R 0121
GHG 960 1955 R 0122
GHG 960 1955 R 0123
GHG 960 1955 R 0124
GHG 960 1955 R 0125
GHG 960 1955 R 0126
GHG 960 1955 R 0127
GHG 960 1955 R 0128

Cable Acceptance
Thread
Length ‘B’ Outer Sheath ‘E’
Metric
Min
Max
12.0
4.0
7.0
12.0
5.5
10.0
13.0
5.5
13.0
13.0
8.0
17.0
15.0
12.0
21.0
15.0
17.0
28.0
16.0
22.0
35.0
16.0
27.0
48.0

Gland
Length ‘F’
(less entry)
19.3
23.0
25.0
29.5
35.5
39.5
44.0
47.0

Hexagon Dimensions
Across Flats

Across Corners ‘G’

15.0
20.0
24.0
29.0
36.0
46.0
55.0
68.0

16.5
22.0
26.4
31.9
39.6
50.6
60.5
74.8

All dimensions in millimeters unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

77

4F

ATEX

Trumpet

IP66

4F

International Standards Flameproof and Increased Safety

Gland Type:
Non-armoured

Cable Type:
Non-armoured

Certifications and Compliances:
• ATEX PTB 00ATEX3121X Ex II 2 G Ex e II/Ex II 2 D Ex tD A21

Features:

• IP66

• Standard material is high-impact resistant polyamide
• Forms weatherproof seal on outer sheath of cable
• Flared rear seal provides protection for cable
• Standard neoprene seal suitable for use in operating temperatures
-40° to 85°C
• Available with metric threads
• See page 101 for related accessories

SELECTION TABLE
Gland
Size
20
25
32
40
50
60

Entry
Metric
Size
M20
M25
M32
M40
M50
M60

Thread Size ‘A’
Metric
Catalog #
GHG 960 1949
GHG 960 1949
GHG 960 1949
GHG 960 1949
GHG 960 1949
GHG 960 1949

R0111
R0112
R0113
R0114
R0115
R0116

Thread Length
‘B’ Metric
15.0
15.0
15.0
15.0
16.0
16.0

Cable Acceptance
Outer Sheath ‘E’
Min
Max
8.0
13.0
11.0
16.0
15.0
20.0
19.0
27.0
26.0
34.0
35.0
46.0

Gland
Length ‘F’
(less entry)
49.0
50.0
65.0
71.0
79.0
89.0

All dimensions in millimeters unless otherwise noted.

78

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Hexagon Dimensions
Across
Across
Flats
Corners ‘G’
26.0
28.6
32.0
35.2
41.0
45.1
50.0
55.0
60.0
66.0
75.0
82.5

Enlargement and Multiple
International Standards Flameproof and Increased Safety

4F

IP66

Sizes M16: PTB 99 ATEX 3101 X
Sizes M20-M63: PTB 99 ATEX
3128 X
IECEx

4F

Gland Type:
Non-armoured

Cable Type:
Non-armoured

Certifications and Compliances:
• Sizes M16: PTB 99 ATEX 3101 X
Sizes M20-M63: PTB 99 ATEX 3128 X
Ex II 2 G Ex e II/Ex II 2 D Ex tD A21

Features:
•
•
•
•

Standard material is high-impact resistant polyamide
Forms weatherproof seal on outer sheath of cable
Provides reduced entry threads for larger gland size
Standard silicone seal suitable for use in operating temperatures
-55° to 70°C (M16 for use in operating temperatures -20° to 70°C)
• Available with metric threads
• See page 101 for related accessories

• IECEx PTB 05.0004X
• IP66

SELECTION TABLE – ENLARGEMENT
Gland
Size
16/20
20/25
25/32
32/40
40/50
50/63

Entry
Metric
Size
M16
M20
M25
M32
M40
M50

Thread Size ‘A’
Metric
Catalog #
GHG 960 1956 R0002
GHG 960 1956 R0003
GHG 960 1956 R0004
GHG 960 1956 R0005
GHG 960 1956 R0006
GHG 960 1956 R0007

Thread
Length ‘B’
Metric
12.0
13.0
13.0
15.0
15.0
16.0

Cable Acceptance
Outer Sheath ‘E’
Min
Max
5.5
13.0
8.0
17.0
12.0
21.0
16.0
28.0
21.0
35.0
27.0
48.0

Gland
Length ‘F’
(less entry)
25.0
29.5
35.5
39.5
44.0
47.0

Hexagon Dimensions
Across
Across
Flats
Corners ‘G’
24.0
26.4
29.0
31.9
36.0
39.6
46.0
50.6
55.0
60.5
68.0
74.8

SELECTION TABLE – MULTIPLE
Gland
Size
25
32

Entry Thread Size ‘A’
Metric
Size Metric Catalog #
M25 GHG 960 1955 R0054
M32 GHG 960 1955 R0055

Thread
Length ‘B’
Metric
8.0
10.0

Cable Acceptance
Outer Sheath ‘E’
Min
Max
4.5
7.0
4.5
7.0

Maximum
Number of
Conductors
2
4

Gland
Length ‘F’
(less entry)
29.5
39.5

Hexagon Dimensions
Across
Across
Flats
Corners ‘G’
36.0
39.6
46.0
50.6

All dimensions in millimeters unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

79

4F

NEMA 4X and IP68

ADE 4I

4F

International Standards Industrial
Gland Type:
Armoured

Cable Type:
Steel wire armoured, steel wire braided, steel tape armoured,
braided marine shipboard lead sheathed (with addition of earthing
washer) and tray cable

Certifications and Compliances:
Features:

• NEMA 4X and IP68

• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping and bonding with no reversible components for
easy installation, minimizing error
• Provides seal on inner jacket and weatherproof seal on outer
sheath of the cable
• An optional earthing washer for use with lead sheathed cable
( see page 97)
• Standard neoprene seal suitable for use in operating temperatures
of -60°C to 100°C
• Available with optional silicone seal for extreme temperatures
• Available with metric or NPT threads
• See pages 96–103 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’

Gland
Size
5
5
6
5
6
7
6
7
8
8
9
9
10
10
11
12
13
13
14
15
16
16
17

Metric
Size
M12
M16
M16
M20
M20
M20
M25
M25
M25
M32
M32
M40
M40
M50
M50
M63
M63
M75
M75
M90
M90
–
M110

Metric
Catalog #
CAP946404
CAP946594
CAP946504
CAP946674
CAP946694
CAP946604
CAP946774
CAP946794
CAP946704
CAP946894
CAP946804
CAP946994
CAP946904
CAP947094
CAP947004
CAP947294
CAP947204
CAP947394
CAP947304
CAP947594
CAP947504
–
CAP947794

NPT
Size
1
/4"
3
/8"
3
/8"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/2"
11/2"
2"
2"
21/2"
21/2"
3"
3"
31/2"
4"

NPT
Catalog #
CAP948404
CAP948594
CAP948504
CAP948674
CAP948694
CAP948604
CAP948774
CAP948795
CAP948704
CAP948894
CAP948804
CAP948994
CAP948904
CAP949904
CAP949004
CAP949294
CAP949204
CAP949949
CAP949404
CAP949564
CAP949504
CAP949604
CAP949704

Cable Acceptance
Thread
Length Inner Sheath Outer Sheath
‘E’
‘D’
‘B’ Metric
Min
Max
Min
Max
(NPT)
15 (12.0)
4.0
8.0
6.0
12.0
15 (12.0)
4.0
8.5
6.0
12.0
15 (12.0)
6.0
12.0
8.5
16.0
15 (20.2)
4.0
8.5
6.0
12.0
15 (20.2)
6.0
12.0
8.5
16.0
15 (20.2)
8.5
16.0
12.0
21.0
15 (20.2)
6.0
12.0
8.5
16.0
15 (20.2)
8.5
16.0
12.0
21.0
15 (20.2) 12.0
20.5
16.0
27.5
15 (25.3) 12.0
21.0
16.0
27.5
15 (25.3) 16.0
27.5
21.0
34.0
15 (26.0) 16.0
27.5
21.0
34.0
15 (26.0) 21.0
34.0
27.0
41.0
16 (26.5) 21.0
34.0
27.0
41.0
16 (26.5) 27.0
41.0
33.0
48.0
17 (27.2) 27.0
41.0
33.0
48.0
17 (27.2) 33.0
48.0
40.0
56.0
18 (40.5) 40.0
56.0
47.0
65.0
18 (40.5) 47.0
65.0
54.0
74.0
22 (42.0) 54.0
74.0
63.0
83.0
22 (42.0) 63.0
82.0
72.0
93.0
– (43.2)
63.0
82.0
72.0
93.0
22 (44.5) 72.0
92.0
85.0 107.0

Armour
(max)
0.9
0.9
1.25
0.9
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
3.15
3.15
3.15

All dimensions in millimeters unless otherwise noted.

80

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Gland
Length
‘F’ (less
entry)
36.0
36.0
42.0
36.0
42.0
46.0
42.0
46.0
56.0
56.0
63.0
63.0
68.0
68.0
74.0
77.0
85.0
85.0
92.0
104.0
108.0
108.0
115.0

Hexagon
Dimensions
Across
Flats
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

Across
Corners
‘G’
20.9
20.9
26.4
26.4
26.4
33.0
33.0
33.0
45.1
45.1
52.8
52.8
60.5
60.5
70.4
79.2
93.5
93.5
104.5
121.0
132.0
132.0
148.5

Terminator™ II TMCX

NEMA 6P
IECEx/ATEX (Pending)

UL/cULus Listed
Cl. I, Div. 1, Groups A, B, C, D
Cl. II, Groups E, F, G
Cl. III

North American Standards Explosionproof

Features:

Armoured barrier, TECK armoured, and
non-armoured barrier

• Designed to minimize the opportunity for
incorrect assembly
• Simple selection process and field
preparation aids to ensure the right gland is
selected every time
• Full coverage of all popular cables and hub
sizes, ensuring a perfect seal in all instances
• Use of nickel-plated brass and stainless steel
to increase corrosion resistance and maintain
integrity in the harshest environments
• Chico® LiquidSeal, an innovative liquid
compound with fast gel and cure times,
reduces waiting times
• Complete with integral dam to facilitate
liquid pour
• Integral union design reduces the number of
times the gland has to be assembled and
disassembled during installation

Cable Type:
Metal-clad and TECK (interlocked and
continuously welded corrugated
armoured), unarmoured, and tray cable

Certifications and
Compliances:
•
•
•
•
•
•

Class I, Division 1, Groups A, B, C, D
Class II, Groups E, F, G
Class III
NEMA 6P
UL/cULus Listed - File No. E122485
IECEx/ATEX (Pending)

• Mating components have generous lead-ins
to ensure that assembly is as trouble-free as
possible, even with the heaviest cables
• Use of neoprene seal allows use in
temperatures from -40°C to +60°C; for
specific temperature information, please
contact your local sales representative
• Metric size threads allow interfacing to
European machinery
• Wide range of global certifications and
approvals
• See page 102 for related accessories

SELECTION TABLE
‘A’ Armour O.D.
Metric
Catalog #

Over
Conductors
O.D. Max.
Inches ‘G’

Entry
Thread
‘C’

NPT
Catalog #

Entry
Thread ‘C’
(Metric
Option)

/ 2"

TMCX050 1

M20

TMCXM20 1

/ 2"

TMCX050 2

M20

/ 4"

TMCX075 1

3

/ 4"

‘B’ Cable O.D.†

Thread
Length
NPT ‘E’
(Metric
mm.)

Length
‘F’

Min.

Max.

Min.

Max.

Across
Corners
‘D’

0.480

0.40
(10.16)

0.86
(21.84)

0.49
(12.45)

0.90
(22.86)

1.75
(44.45)

1.00
(25.40)

3.05
(77.47)

TMCXM20 2

0.480

0.56
(14.22)

1.14
(28.96)

0.65
(16.51)

1.18
(29.97)

2.25
(57.15)

1.00
(25.40)

3.18
(80.77)

M25

TMCXM25 1

0.713

0.40
(10.16)

0.86
(21.84)

0.49
(12.45)

0.90
(22.86)

1.75
(44.45)

1.00
(25.40)

3.05
(77.47)

TMCX075 2

M25

TMCXM25 2

0.713

0.56
(14.22)

1.14
(28.96)

0.65
(16.51)

1.18
(29.97)

2.25
(57.15)

1.00
(25.40)

3.18
(80.77)

1"

TMCX100 1

M32

TMCXM32 1

0.939

0.56
(14.22)

1.14
(28.96)

0.65
(16.51)

1.18
(29.97)

2.25
(57.15)

1.08
(27.40)

3.18
(80.77)

1"

TMCX100 2

M32

TMCXM32 2

0.939

0.78
(19.81)

1.35
(34.29)

0.87
(22.10)

1.39
(35.31)

2.56
(65.02)

1.08
(27.40)

3.30
(83.82)

11/ 4"

TMCX125 1

M40

TMCXM40 1

1.172

0.78
(19.81)

1.35
(34.29)

0.87
(22.10)

1.39
(35.31)

2.56
(65.02)

1.08
(27.40)

3.30
(83.82)

1

1

3

All dimensions in inches; metric millimeters shown in parenthesis. Sizes 11/ 2" and above will be available soon.
†When making your cable gland selection based on Cable O.D., be sure to also observe the Over Conductors O.D. dimension.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

D

B

F

G

A

C

E

Copyright© 2013 Eaton’s Crouse-Hinds Business

81

4F

Gland Type:

4F

Terminator™ II TMCX

4F

4F

North American Standards Explosionproof

UL/cULus Listed
Cl. I, Div. 1, Groups A, B, C, D
Cl. II, Groups E, F, G
Cl. III

NEMA 6P
IECEx/ATEX (Pending)

Catalog Numbering System:

TMCX

050

Hub Size

1

NP
Material

NPT

Hub (in.)

Metric

Hub (mm.)

BLANK

Aluminum

050

½”

M20

20

SS

316 Stainless Steel

075

¾”

M25

25

NP

Nickel-plated Brass

100

1”

M32

32

125

1-¼”

M40

40

Compound Type

Cable Sealing Range
Hub Size
Code

Thread

050

½”

075

¾”

NPT
NPT

100

1”

NPT

125

1-¼”

NPT

M20
M25

M20
M25

ISO
ISO

M32

M32

ISO

M40

M40

ISO

82

L

Sealing
Range
Code

Standard Cable
Sealing Range

1

0.49” - 0.90”

2

0.65” - 1.18”

1

0.49” - 0.90”

2

0.65” - 1.18”

1

0.65” - 1.18”

2

0.87” - 1.39”

1

0.87” - 1.39”

1

12.4 mm - 22.8 mm

2

16.5 mm - 29.9 mm

1

12.4 mm - 22.8 mm

2

16.5 mm - 29.9 mm

1

16.5 mm - 29.9 mm

2

22.0 mm - 35.3 mm

1

22.0 mm - 35.3 mm

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

BLANK

TSC

L

Liquid

TMCX
North American Standards Explosionproof

4F

NEMA 4 and IP56
UL Listed
CSA Certified Class I, Div. 1, Wet locations
Groups A, B, C, D
Class II; Class III

4F

Gland Type:
Armoured barrier, TECK armoured and non-armoured barrier

Cable Type:
Metal-clad (interlocked or continuously welded corrugated
armoured), non-armoured and tray cable

Certifications and Compliances:
• UL Listed, CSA Certified Class I, Div. 1, Groups, A, B, C, D;
Class II; Class III – UL File E122485, CSA File LR13046

Features:

• NEMA 4 and IP56 rated

• Standard material is aluminum
• Stainless steel copper-plated spring provides grounding continuity
of cable armour (MC cable only)
• Provides explosionproof compound seal on conductors and
watertight seal on outer sheath of cable
• Standard neoprene seal suitable for use in operating temperatures
-25° to 60°C
• Cold Shrink™ Kit is available for extra protection in aggressive
environments (see page 102)
• Available with NPT threads
• See page 102 for related accessories

• Wet locations

SELECTION TABLE
Entry Thread Size ‘A’
NPT
Size
1
/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

NPT
Catalog #
TMCX165
TMCX285
TMCX3112
TMCX4140
TMCX5161
TMCX6206
TMCX7247
TMCX8302
TMCX9352
TMCX10402

Cable Acceptance
Thread
Length
‘B’ NPT
0.750
0.781
0.938
0.969
0.969
1.000
1.438
1.438
1.625
1.625

Armour Range ‘H’
Min
0.440
0.600
0.800
1.100
1.330
1.570
1.930
2.450
2.950
3.500

Max
0.650
0.850
1.120
1.400
1.610
2.060
2.470
3.020
3.520
4.020

Hexagon Dimensions

Outer Sheath ‘E’
Min
0.490
0.650
0.850
1.150
1.380
1.630
1.990
2.525
3.025
3.585

Max
0.781
1.000
1.313
1.625
1.781
2.313
2.719
3.281
3.781
4.281

Gland Length
‘F’ (less entry)
2.625
2.875
3.125
3.125
3.375
5.313
6.063
6.063
7.750
8.313

Across
Flats
1.250
1.500
1.875
2.250
2.500
3.250
3.750
4.500
5.000
5.500

Across
Corners ‘G’
1.375
1.625
2.000
2.438
2.750
3.500
4.000
4.875
5.375
5.875

All dimensions in inches unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

83

4F

CEPEL
ATEX
GOST-R
IECEx
NEMA 4X and IP68
cULus Listed for Class I, Zone 2
cULus Marine Listed for Class I, Div. 1

ADE 6FC

4F

North American Standards Explosionproof
Gland Type:
Armoured barrier

Cable Type:
Steel wire armoured, steel wire braided, steel tape armoured,
braided marine shipboard and lead sheathed (with addition of
earthing washer)

Certifications and Compliances:

Features:

•
•
•
•
•
•
•
•
•

ATEX LCIE 97 ATEX 6008X - Exd IIC/Exe II/Ex tD/Ex II 2 GD
IECEx LCI 05.0004X
cULus Listed for Class I, Zone 2 AEx de II/Ex de II
cULus Marine Listed for Class I, Division 1, Groups A, B, C, D
NEMA 4X and IP68
CEPEL-EX-558/05X
GOST-R POCC FR Bo2011
NEPSI N° GYJ071336U & GYJ071337U
ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• DNV N° E-10892
• Lloyds

• Standard material is nickel-plated brass for superior corrosion
resistance
• Armour clamping with no reversible components for easy
installation, minimizing error
• Provides explosionproof compound seal (denoted by red back nut)
on conductors and weatherproof seal on outer sheath of cable
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
-60°C (-25°C UL) to 80°C
• Available with metric or NPT threads
• See pages 96–99 for related accessories

ORDERING EXAMPLE:
CAP96959 4 KX
Gland Type

Options

OPTIONS (replace last digit with option number):
9
8
7
K1
K2

Stainless steel (316L)
Bronze
Aluminum
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud

SELECTION TABLE
Entry Thread Size ‘A’

Gland Metric
Size
Size
5
M16
5
M20
6
M20
7
M20
7
M25
8
M25
8
M32
9
M32
9
M40
10
M40
10
M50
11
M50
12
M63
13
M63
13
M75
14
M75
14
–
15
M90
15
–
16
M90
16
–
17
M110

Metric
Catalog #
CAP969594
CAP969674
CAP969694
CAP969604
CAP969794
CAP969704
CAP969894
CAP969804
CAP969994
CAP969904
CAP970094
CAP970004
CAP970294
CAP970204
CAP970394
CAP970304
–
CAP970594
–
CAP970504
–
CAP970794

NPT
Size
3
/8"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/2"
11/2"
2"
2"
21/2"
21/2"
3"
3"
31/2"
3"
31/2"
4"

NPT
Catalog #
CAP974594
CAP971674
CAP971674
CAP971604
CAP971794
CAP971704
CAP971894
CAP971804
CAP971994
CAP971904
CAP972094
CAP972004
CAP972274
CAP972204
CAP972494
CAP972404
CAP972574
CAP972594
CAP972694
CAP972504
CAP972604
CAP972704

Thread
Length
‘B’
Metric
(NPT)
15 (12.0)
15 (20.2)
15 (20.2)
15 (20.2)
15 (20.5)
15 (20.5)
15 (25.3)
15 (25.3)
15 (26.0)
15 (26.0)
16 (26.5)
16 (27.2)
17 (29.2)
17 (29.2)
18 (42.5)
18 (42.5)
(44)
22 (44.0)
(45.2)
22 (44.0)
(45.2)
22 (46.5)

Hexagon
Cable Acceptance
Dimensions
Inner Sheath
Outer
and Cores
Sheath ‘E’
Gland
Max
Max
Length
Over Inner
Max
Across
Armour ‘F’ (less Across Corners
Cores Sheath No. of
(max)
entry)
'C'
'D'
Cores Min Max
Flats
‘G’
6.5
7.5
6.0
6.0
12.0
0.9
46.0
–
20.9
6.5
7.5
6.0
6.0
12.0
0.9
46.0
–
26.4
9.5
11.0
6.0
8.5
16.0
1.25
53.0
–
26.4
12.0
14.5
10.0
12.0 21.0
1.25
59.0
–
33.0
12.0
14.5
10.0
12.0 21.0
1.25
59.0
–
33.0
17.0
19.5
21.0
16.0 27.5
1.6
74.5
–
45.1
17.0
19.5
21.0
16.0 27.5
1.6
74.5
–
45.1
23.0
28.0
42.0
21.0 34.0
1.6
83.5
–
52.8
23.0
28.0
42.0
21.0 34.0
1.6
83.5
–
52.8
29.0
33.0
60.0
27.0 41.0
2.0
92.0
–
60.5
29.0
33.0
60.0
27.0 41.0
2.0
92.0
–
60.5
36.5
41.0
80.0
33.0 48.0
2.5
104.0
–
70.4
43.0
48.0
100.0 40.0 56.0
2.5
108.0
–
79.2
50.0
56.0
100.0 46.0 65.0
2.5
118.0
–
93.5
50.0
56.0
100.0 46.0 65.0
2.5
118.0
–
93.5
59.0
65.0
120.0 54.0 74.0
2.5
124.0
–
104.5
59.0
65.0
120.0 54.0 74.0
2.5
124.0
–
104.5
66.0
73.0
140.0 63.0 83.0
3.15
133.0
–
121.0
66.0
73.0
140.0 63.0 83.0
3.15
133.0
–
121.0
75.0
82.0
140.0 72.0 93.0
3.15
137.0
–
132.0
75.0 82.0** 140.0 72.0 93.0
3.15
137.0
–
132.0
85.0 92.0** 200.0 85.0 107.0
3.15
142.0
–
148.5

All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your field sales representative for amended UL marine range.

84

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

ADE 1FC

ATEX
IECEx
cULus Listed for Class I, Zone 2
UL Marine Listed for Class I, Div. 2

North American Standards Explosionproof

CEPEL
GOST-R
NEMA 4X and IP68

4F

4F

Gland Type:
Non-armoured barrier

Cable Type:
Non-armoured, armoured and tray cable (does not terminate the
armour)

Certifications and Compliances:

Features:

•
•
•
•
•
•
•
•
•
•

LCIE 97 ATEX 6008X II GD - Exd IIC/Exe II/Ex tD
IECEx LCI 05.0004X Ex c e IIC/Ex c e II/Ex tD
cULus Listed for Class I, Zone 2 AEx de II/Ex de II
UL Marine Listed for Class I, Division 2, Groups A, B, C, D
NEMA 4X and IP68
CEPEL EX-558/05X
GOST-R POCC FR.B03126
NEPSI N° GYJ071336U & GYJ071337U
DNV N° E-10892
ABS approbation:
n° 10-HS 577243-PDA / P1836754-X
• Lloyds

• Standard material is nickel-plated brass for superior corrosion
resistance
• Provides a flameproof and weatherproof seal on outer sheath of
cable
• Provides explosionproof compound seal (denoted by red back nut)
on conductors
• Deluge boot provides enhanced protection from water ingress
• Standard neoprene seal suitable for use in operating temperatures
-60°C (-25°C UL) to 80°C
• Available with metric or NPT threads
• See pages 96–99 for related accessories

ORDERING EXAMPLE:
CAP01959 4 KX
Gland Type

Options

OPTIONS (replace last digit with option number):
9
8
7
K1
K2

Stainless steel (316L)
Bronze
Aluminum
Includes locknut and fiber washer
Includes locknut, fiber washer, earth tag, and
shroud

SELECTION TABLE
Entry Thread Size ‘A’
Gland
Size
4
4
5
6
6
7
7
8
8
9
9
10
10
11
12
12
13
13
14
14
15
15
16

Metric
Size
M16
M20
M20
M20
M25
M25
M32
M32
M40
M40
M50
M50
M63
M63
M63
–
M75
–
M90
–
M90
–
M110

Metric
Catalog #
CAP019594
CAP019674
CAP019694
CAP019604
CAP019794
CAP019704
CAP019894
CAP019804
CAP019994
CAP019904
CAP019094
CAP019004
CAP019204
CAP019294
CAP019274
–
CAP019304
–
CAP010594
–
CAP010504
–
CAP010794

NPT
Size
3
/8"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/2"
2"
–
2"
2"
21/2"
21/2"
3"
3"
31/2"
3"
31/2"
4"

NPT
Catalog #
CAP011594
CAP011674
CAP011694
CAP011604
CAP011794
CAP011704
CAP011894
CAP011804
CAP011994
CAP011904
CAP011094
CAP011004
–
CAP011294
CAP011204
CAP011494
CAP011404
CAP012504
CAP012574
CAP012604
CAP012594
CAP012694
CAP012704

Thread
Cable Acceptance
Length
Outer Sheath ‘E’
‘B’ Metric
Min
Max
(NPT)
15 (12.0)
4.0
7.5
15 (22.2)
4.0
7.5
15 (22.2)
6.5
11.0
15 (22.2)
9.0
14.5
15 (22.5)
9.0
14.5
15 (22.5)
12.0
19.5
15 (27.3)
12.0
19.5
15 (27.3)
17.5
26.0
15 (28.0)
17.5
26.0
15 (28.0)
23.0
33.0
16 (28.5)
23.0
33.0
16 (29.2)
28.5
41.0
16
28.5
41.0
17 (29.2)
43.0
48.0
17 (29.2)
50.0
56.0
42.5
50.0
56.0
18 (42.5)
59.0
65.0
44
59.0
65.0
22 (44.0)
66.0
73.0
45.2
66.0
73.0
22 (44.0)
75.0
82.0
45.2
75.0
82.0**
22 (46.5)
85.0
92.0**

Hexagon
Dimensions
Gland
Max No. Length ‘F’ Across
Across
Cores (less entry) Flats Corners ‘G’
6.0
46.0
–
20.9
6.0
46.0
–
26.4
6.0
53.0
–
26.4
10.0
59.0
–
33.0
10.0
59.0
–
33.0
21.0
74.5
–
45.1
21.0
74.5
–
45.1
42.0
83.5
–
52.8
42.0
83.5
–
52.8
60.0
92.0
–
60.5
60.0
92.0
–
60.5
80.0
104.0
–
70.4
80.0
–
–
73.7
100.0
98.0
–
70.4
100.0
103.0
–
79.2
100.0
103.0
–
79.2
120.0
111.0
–
93.5
120.0
111.0
–
93.5
140.0
120.0
–
104.5
140.0
120.0
–
104.5
140.0
125.0
–
121.0
140.0
125.0
–
121.0
200.0
128.0
–
132.0

All dimensions in millimeters unless otherwise noted.
*Aluminum not currently available with UL marine certification.
**Contact Customer Service or your field sales representative for amended UL marine range.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

85

CGBS and EBY

4F

4F

EBY:
CGBS:
UL, cUL Listed Class I,
CSA Certified Class I,
Div. 1, Groups B, C, D
Div.
1,
Groups
C,
D
North American Standards Class II, Div. 1, Groups F, G
Class II, Div. 1 & 2, Groups E, F, G
Explosionproof
Class III

Gland Type:
Portable cord connector

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• CSA Certified Class I, Div. 1, Groups C, D
• Class II, Div. 1 & 2, Groups E, F, G

CGBS Features:

• Class III – CSA File LR13046

• Body – steel with zinc electroplate and chromate finish coat
• Gland nut – aluminum
• Body well for Chico A sealing compound (for ordering
information please contact customer service)
• Standard neoprene seal suitable for use in operating
temperatures -25° to 40°C
• Available with NPT threads

SELECTION TABLE
Entry
NPT Size
1
/2"
3
/4"
3
/4"
1"
1"
11/4"
11/4"
11/4"

Thread Size ‘A’

Outer Sheath ‘E’

Form

NPT Catalog #
CGBS1013
CGBS2013
CGBS2014
CGBS3015
CGBS3016
CGBS4017
CGBS4018
CGBS4019

Min
0.312
0.312
0.375
0.500
0.625
0.750
0.875
1.000

A
A
A
B
B
B
B
B

Max
0.437
0.437
0.500
0.625
0.750
0.875
1.000
1.188

Gland Length ‘F’ (less entry)
51/4"
51/4"
51/4"
27/8"
215/16"
213/16"
31/2"
39/16"

All dimensions in inches unless otherwise noted.

Gland Type:
Portable cord connector

Cable Type:
Non-armoured

Certifications and Compliances:
• UL, cUL Listed Class I, Div. 1, Groups B, C, D

EBY Features:

• Class II, Div. 1, Groups, F, G – UL File E10279

• Standard material is aluminum
• Factory sealed conductors and seal on outer sheath of cable
• Three, 12-inch long, #12 type SF-2 (150°C rating) stranded
pigtails; two circuit wires and one identified
grounding wire
• Three pressure connectors for 3-conductor cord,
range #18 to #12 AWG
• Standard neoprene seal suitable for use in operating
temperatures -25° to 40°C
• Available with NPT threads

SELECTION TABLE
Entry Thread Size ‘A’
NPT Size
3
/4"
3
/4"
3
/4"

Outer Sheath ‘E’
Min
Max
0.250
0.437
0.375
0.500
0.500
0.625

NPT Catalog #
EBY2672
EBY2682
EBY26102

All dimensions in inches unless otherwise noted.

86

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

TMC

UL, CSA Listed

4F

NEMA 4 and IP56
Wet locations

North American Standards General Purpose
4F

Gland Type:
Armoured and TECK armoured

Cable Type:
Metal-clad (interlocked or continuously welded corrugated armoured)
and TECK

Certifications and Compliances:
•
•
•
•

UL Listed – UL File E36379
CSA Listed – CSA File LR291
NEMA 4 and IP56
Wet locations

Features:
• Standard material is aluminum
• Stainless steel copper-plated spring provides grounding continuity
of cable armour
• Watertight seal on outer sheath of cable
• Standard neoprene seal suitable for use in operating temperatures
-25° to 60°C
• Cold Shrink™ Kit is available for extra protection in aggressive
environments (see page 102)
• Available with NPT threads
• See page 102 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’
NPT
Size
1
/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

NPT
Catalog #
TMC165
TMC285
TMC3112
TMC4140
TMC5161
TMC6206
TMC7247
TMC8302
TMC9352
TMC10402

Thread
Length
‘B’ NPT
0.750
0.781
0.938
0.969
0.969
1.000
1.438
1.438
1.625
1.625

Cable Acceptance
Armour Range ‘H’
Min
Max
0.440
0.650
0.600
0.850
0.800
1.120
1.100
1.400
1.330
1.610
1.570
2.060
1.930
2.470
2.450
3.020
2.950
3.520
3.500
4.020

Outer Sheath ‘E’
Min
Max
0.490
0.781
0.650
1.000
0.850
1.313
1.150
1.625
1.380
1.781
1.630
2.313
1.990
2.719
2.525
3.281
3.025
3.781
3.585
4.281

Gland
Length
‘F’ (less
entry)
2.375
2.625
2.625
2.750
2.750
4.500
4.750
4.875
5.375
5.500

Hexagon Dimensions
Across
Flats
1.250
1.500
1.875
2.250
2.500
3.250
3.750
4.500
5.000
5.500

Across
Corners ‘G’
1.375
1.625
2.000
2.438
2.75
3.500
4.000
4.875
5.375
5.875

All dimensions in inches unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

87

TECK

4F

CSA Certified Class II, Div. 1 & 2, Groups E, F, G
Class III - CSA

Type 4 and IP56
Wet locations

4F

North American Standards General Purpose
Gland Type:
Armoured

Cable Type:
TECK armoured

Certifications and Compliances:
• CSA Certified Class II, Div. 1 & 2, Groups E, F, G; Class III –
CSA File LR13046
• Type 4 and IP56

Features:

• Wet locations

• Standard material is aluminum
• Stainless steel copper-plated spring provides grounding continuity
of cable armour (TECK cable only)
• Watertight seal on outer sheath of cable
• Standard neoprene seal suitable for use in operating temperatures
-25° to 60°C
• Cold Shrink™ Kit is available for extra protection in aggressive
environments (see page 102)
• An integral o-ring seal on entry threads
• Available with NPT threads
• See page 102 for related accessories

SELECTION TABLE

Aluminum
Catalog #
TECK050 1
TECK050 2
TECK050 3
TECK050 4
TECK075 5
TECK075 6
TECK100 7
TECK125 8
TECK125 9
TECK125 10
TECK150 11
TECK150 12
TECK200 13
TECK200 14
TECK200 15
TECK200 16
TECK250 17
TECK250 18
TECK300 19
TECK300 20
TECK300 21
TECK350 22
TECK350 23
TECK400 24
TECK400 25
TECK400 26

Steel
Catalog #
TECK050 1S
TECK050 2S
TECK050 3S
TECK050 4S
TECK075 5S
TECK075 6S
TECK100 7S
TECK125 8S
TECK125 9S
TECK125 10S
TECK150 11S
TECK150 12S
TECK200 13S
TECK200 14S
TECK200 15S
TECK200 16S
TECK250 17S
TECK250 18S
TECK300 19S
TECK300 20S
TECK300 21S
TECK350 22S
TECK350 23S
TECK400 24S
TECK400 25S
TECK400 26S

Stainless
Steel
Catalog #
TECK050 1SS
TECK050 2SS
TECK050 3SS
TECK050 4SS
TECK075 5SS
TECK075 6SS
TECK100 7SS
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

PVC Catalog #
TECK050 1PVC
TECK050 2 PVC
TECK0503PVC
TECK050 4PVC
TECK075 5PVC
TECK075 6PVC
TECK1007PVC
TECK125 8PVC
TECK125 9PVC
TECK125 10PVC
TECK150 11PVC
TECK150 12PVC
TECK200 13PVC
TECK200 14PVC
TECK200 15PVC
TECK200 16PVC
TECK250 17PVC
TECK250 18PVC
TECK300 19PVC
TECK300 20PVC
TECK300 21PVC
TECK350 22PVC
TECK350 23PVC
–
–
–

Hexagon
Gland
Entry
Cable Acceptance
Dimensions
Length
Thread
‘F’
Across
Size ‘A’ Thread Armour Range ‘H’ Outer Sheath ‘E’
(less Across Corners
NPT Length
Min
Max
Min
Max entry)
Size ‘B’ NPT
‘G’
Flats
1
/2"
0.630
0.415
0.570
0.525
0.650
2.300 1.250
1.350
1
/2"
0.630
0.490
0.680
0.600
0.760
2.300 1.375
1.500
1
/2"
0.630
0.615
0.805
0.725
0.885
2.300 1.500
1.600
1
/2"
0.630
0.715
0.905
0.825
0.985
2.300 1.500
1.600
3
/4"
0.630
0.770
0.985
0.880
1.065
2.500 2.000
2.125
3
/4"
0.630
0.915
1.125
1.025
1.205
2.500 2.000
2.125
1"
0.750
1.077
1.295
1.187
1.375
2.625 2.250
2.400
0.800
1.240
1.545
1.350
1.625
3.500 3.000
3.125
11/4"
11/4"
0.800
1.390
1.545
1.500
1.625
3.400 3.000
3.125
11/4"
0.800
1.490
1.795
1.600
1.875
3.500 3.000
3.125
11/2"
0.800
1.590
1.885
1.700
1.965
3.800 3.750
3.600
11/2"
0.800
1.790
2.107
1.900
2.187
3.900 3.500
3.750
2"
0.825
1.790
2.107
1.900
2.187
4.000 3.750
4.000
2"
0.825
1.990
2.280
2.100
2.375
4.000 3.750
4.000
2"
0.875
2.190
2.485
2.300
2.565
4.000 4.125
4.400
2"
0.875
2.390
2.656
2.500
2.750
4.000 4.125
4.400
21/2"
1.300
2.240
2.560
2.380
2.640
5.000 4.500
4.750
21/2"
1.300
2.440
2.750
2.580
2.840
5.000 4.500
4.750
3"
1.400
2.640
2.970
2.790
3.060
5.000 4.600
4.900
3"
1.400
2.870
3.190
3.000
3.270
5.000 4.900
5.250
3"
1.400
3.042
3.390
3.210
3.480
5.000 5.000
5.250
31/2"
1.400
3.270
3.590
3.420
3.690
5.000 5.600
5.900
31/2"
1.400
3.440
3.770
3.610
3.870
5.000 5.500
5.900
4"
1.400
3.600
3.930
3.810
4.030
5.000 6.125
6.500
4"
1.400
3.755
4.065
3.965
4.185
5.000 6.125
6.500
4"
1.400
3.910
4.220
4.120
4.340
5.000 6.125
6.500

All dimensions in inches unless otherwise noted.

88

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

CGB

4F

cULus Listed

North American Standards General Purpose
4F

Gland Type:
Non-armoured

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• cULus Listed - UL File E23223
• Suitable for use in Class I, Div. 2 hazardous locations when
installed in accordance with NEC501.10(B)(2)

Features:
• Form A - D bodies and gland nuts – steel with zinc electroplate
and chromate finish coat
• Form E - F bodies and gland nuts – Feraloy® iron alloy with
electrogalvanized and aluminum acrylic paint
• Weatherproof seal on outer sheath of cable
• Standard neoprene seal suitable for use in operating temperatures
-25° to 40°C
• Available with NPT threads
• Available in all aluminum construction
• See page 102 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’
NPT
Size
3
/8"
3
/8"
3
/8"
3
/8"
3
/8"
3
/8"
1
/2"
1
/2"
1
/2"
1
/2"
1
/2"
1
/2"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
1"
1"
1"
1"
1"
1"
1"
1"
1"

NPT
Catalog #
CGB3814
CGB3816
CGB3817
CGB3892
CGB3893
CGB3894
CGB114†
CGB116†
CGB117†
CGB192*†
CGB193*†
CGB194*†
CGB195*†
CGB196*
CGB197*†
CGB292†
CGB293†
CGB294†
CGB295†
CGB296*†
CGB297*†
CGB298*†
CGB393†
CGB394†
CGB395*†
CGB396*†
CGB397*†
CGB3239†
CGB398*†
CGB399*†
CGB3911*†

Cable Acceptance
Form

Thread
Length ‘B’
NPT

A
A
A
B
B
B
A
A
A
B
B
B
B
C
C
B
B
B
B
C
C
D
B
B
C
C
C
C
D
D
D

0.438
0.438
0.438
0.438
0.438
0.438
0.625†
0.625†
0.625†
0.750*†
0.750*†
0.750*†
0.750*†
0.625*
0.625*†
0.625†
0.625†
0.625†
0.625†
0.625*†
0.625*†
0.625*†
0.688†
0.688†
0.688*†
0.688*†
0.688*†
0.688†
0.625*†
0.625*†
0.625*†

Hexagon Dimensions

Min

Max

Gland
Length ‘F’
(less entry)

0.125
0.250
0.375
0.125
0.250
0.375
0.125
0.250
0.375
0.125
0.250
0.375
0.500
0.625
0.750
0.125
0.250
0.375
0.500
0.625
0.750
0.875
0.250
0.375
0.500
0.625
0.750
0.875
0.875
1.000
1.188

0.250
0.375
0.437
0.250
0.375
0.500
0.250
0.375
0.437
0.250
0.375
0.500
0.625
0.750
0.875
0.250
0.375
0.500
0.625
0.750
0.875
1.000
0.375
0.500
0.625
0.750
0.875
1.000
1.000
1.188
1.375

1.063
1.063
1.063
1.313
1.313
1.313
1.000
1.000
1.000
1.313
1.313
1.313
1.313
1.750
1.750
1.375
1.375
1.375
1.375
1.750
1.750
2.500
1.375
1.375
1.688
1.688
1.688
1.688
2.375
2.375
2.375

Outer Sheath ‘E’

External
Diameter
‘G’

Across
Flats

Across
Corners ‘G’

–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2.250
–
–
–
–
–
–
2.375
2.375
2.375

0.750
0.750
0.750
1.000
1.000
1.000
0.875
0.875
0.875
1.000
1.000
1.000
1.000
1.500
1.500
1.060
1.060
1.060
1.060
1.630
1.630
–
1.375
1.375
1.500
1.500
1.500
–
–
–
–

0.875
0.875
0.875
1.188
1.188
1.188
1.188
1.188
1.188
1.188
1.188
1.188
1.188
1.656
1.656
1.250
1.250
1.250
1.250
1.656
1.656
–
1.625
1.625
1.875
1.875
1.875
1.875
–
–
–

All dimensions in inches unless otherwise noted.
*With optional Sealing Gasket.
†With optional Aluminum Construction.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

89

4F

cULus Listed

CGB

4F

North American Standards General Purpose
Entry Thread Size ‘A’
NPT
Size
11/4"
11/4"
11/4"
11/4"
11/4"
11/2"
11/2"
11/2"
11/2"
11/2"
2"
2"
2"
2"
21/2"
21/2"
21/2"
21/2"
3"
3"

90

NPT
Catalog #
CGB498
CGB499
CGB4911
CGB4913
CGB4915
CGB598
CGB599
CGB5911
CGB5913
CGB5915
CGB6913
CGB6915
CGB6917
CGB6920
CGB7913
CGB7915
CGB7917
CGB7920
CGB8917
CGB8920

www.crouse-hinds.com

Form
D
D
D
E
E
D
D
D
E
E
E
E
F
F
E
E
F
F
F
F

Thread
Length ‘B’
NPT
0.688
0.688
0.688
0.688
0.688
0.813
0.813
0.813
0.813
0.813
0.813
0.813
0.813
0.813
1.000
1.000
1.000
1.000
1.000
1.000

US: 1-866-764-5454

Cable Acceptance
Outer Sheath ‘E’
Min
0.875
1.000
1.188
1.375
1.625
0.875
1.000
1.188
1.375
1.625
1.375
1.625
1.875
2.188
1.375
1.625
1.875
2.188
1.875
2.188

CAN: 1-800-265-0502

Max
1.000
1.188
1.375
1.625
1.875
1.000
1.188
1.375
1.625
1.875
1.625
1.875
2.188
2.500
1.625
1.875
2.188
2.500
2.188
2.500

Gland
Length ‘F’
(less entry)
2.313
2.313
2.313
2.625
2.625
2.313
2.313
2.313
2.625
2.625
2.625
2.625
2.563
2.563
2.625
2.625
2.625
2.625
2.625
2.625

External
Diameter
‘G’
2.250
2.250
2.250
3.000
3.000
2.250
2.250
2.250
3.000
3.000
3.000
3.000
3.750
3.750
3.125
3.125
3.750
3.750
3.750
3.750

Copyright© 2013 Eaton’s Crouse-Hinds Business

Hexagon Dimensions
Across
Flats
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

Across
Corners ‘G’
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

CGD

4F

cULus Listed

North American Standards General Purpose

4F

Gland Type:
Non-armoured

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• cULus Listed - UL File E23223
• Suitable for use in Class I, Div. 2 hazardous locations when
installed in accordance with NEC501.10(B)(2)

Features:
•
•
•
•
•

45° angle with male thread
Standard body material is Feraloy® iron alloy
Standard gland nut material is steel
Weatherproof seal on outer sheath of cable
Standard neoprene seal suitable for use in operating temperatures
-25° to 40°C
• Available with NPT threads
• See page 102 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’
NPT Size NPT Catalog #
1
/2"
CGD192
/2"
/2"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
1
1

Thread Length
‘B’ NPT
0.630

CGD193
CGD194
CGD195
CGD196
CGD197
CGD292
CGD293
CGD294
CGD295
CGD296
CGD297

0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630

Cable Acceptance
Outer Sheath ‘E’
Min
Max
0.125
0.250
0.250
0.375
0.500
0.625
0.750
0.125
0.250
0.375
0.500
0.625
0.750

Gland Length
‘F’ (less entry)
1.688

External
Diameter ‘G’
1.188

1.688
1.688
1.688
2.063
2.063
1.938
1.938
1.938
1.938
2.000
2.000

1.188
1.188
1.188
1.625
1.625
1.141
1.141
1.125
1.125
1.625
1.625

0.375
0.500
0.625
0.750
0.875
0.250
0.375
0.500
0.625
0.750
0.875

All dimensions in inches unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

91

4F

cULus Listed

CGE

4F

North American Standards General Purpose
Gland Type:
Non-armoured

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• cULus Listed - UL File E23223
• Suitable for use in Class I, Div. 2 hazardous locations when
installed in accordance with NEC501.10(B)(2)

Features:
•
•
•
•
•

90° angle with male thread
Standard body material is Feraloy® iron alloy
Standard gland nut material is steel
Weatherproof seal on outer sheath of cable
Standard neoprene seal suitable for use in operating temperatures
-25° to 40°C
• Available with NPT threads
• See page 102 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’
NPT
Size

NPT
Catalog #

Thread
Length
‘B’ NPT

/2"
/2"
1
/2"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
3
/4"
1"
1"
1"
1"
1"
1"
1"

CGE192
CGE193
CGE194
CGE195
CGE196
CGE197
CGE292
CGE293
CGE294
CGE295
CGE296
CGE297
CGE395
CGE396
CGE397
CGE3239
CGE398
CGE399
CGE3911

0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710
0.710

1
1

Cable Acceptance
Outer Sheath ‘E’
Min

Max

Gland Length
‘F’ (less entry)

External
Diameter ‘G’

0.1250
0.2500
0.3750
0.5000
0.6250
0.7500
0.1250
0.2500
0.3750
0.5000
0.6250
0.7500
0.5000
0.6250
0.7500
0.8750
0.8750
1.0000
1.1880

0.2500
0.3750
0.5000
0.6250
0.7500
0.8750
0.2500
0.3750
0.5000
0.6250
0.7500
0.8750
0.6250
0.7500
0.8750
1.0000
1.0000
1.1880
1.3750

1.438
1.438
1.438
1.438
2.000
2.000
1.406
1.406
1.406
1.406
1.875
1.875
2.063
2.094
2.094
2.094
2.656
2.656
2.656

1.188
1.188
1.188
1.188
1.625
1.625
1.188
1.188
1.188
1.188
1.625
1.625
1.625
1.625
1.625
2.250
2.250
1.625
2.250

All dimensions in inches unless otherwise noted.

92

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

CGB1013

4F

cULus Listed

North American Standards General Purpose

4F

Gland Type:
Portable cord connector

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• cULus Listed - UL File E23223
• Suitable for use in Class I, Div. 2 hazardous locations when
installed in accordance with NEC501.10(B)(2)

Features:
• Body – steel with zinc electroplate and chromate finish coat
• Gland nut – material is aluminum
• Standard neoprene seal suitable for use in operating temperatures
-25° to 40°C
• Available with NPT threads
• See page 102 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’
NPT Size
NPT Catalog #
1
/2"
CGB1013
1
/2"
CGB1014
1
/2"
CGB1015
3
/4"
CGB2013
3
/4"
CGB2014
3
/4"
CGB2015

Outer Sheath ‘E’
Min
0.312
0.375
0.500
0.312
0.375
0.500

Max
0.437
0.500
0.625
0.437
0.500
0.625

All dimensions in inches unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

93

4F

CGFP

4F

North American Standards General Purpose

Gland Type:
Non-armoured

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• Suitable for use in Class I, Div. 2 hazardous locations when
installed in accordance with NEC501.10(B)(2)

Features:
• Form B - C standard body and gland nut are turned steel
• Form D - G standard body and gland nut are Feraloy® iron alloy
• Weatherproof seal on outer sheath of cable
• Standard neoprene seal suitable for use in operating temperatures
-25° to 40°C
• Available with NPT threads
• See page 102 for related accessories

SELECTION TABLE
Entry Thread Size ‘A’
NPT Size
1
/2"
1
/2"
1
/2"
1
/2"
3
/4"
3
/4"
3
/4"
1"
1"
1"
11/4"
11/4"
11/2"
11/2"
2"
2"
21/2"
21/2"
3"
3"
31/2"
31/2"
4"
4"

NPT Catalog #
CGFP192
CGFP193
CGFP194
CGFP195
CGFP296
CGFP297
CGFP2239
CGFP396
CGFP397
CGFP3239
CGFP499
CGFP4911
CGFP599
CGFP5911
CGFP6913
CGFP6915
CGFP7917
CGFP7920
CGFP8917
CGFP8920
CGFP923
CGFP927
CGFP1023
CGFP1027

Form
B
B
B
B
C
C
C
C
C
C
D
D
D
D
E
E
F
F
F
F
G
G
G
G

Thread Length
‘B’ NPT
0.750
0.750
0.750
0.750
0.750
0.750
0.750
0.938
0.938
0.938
0.938
0.938
0.938
0.938
1.000
1.000
1.438
1.438
1.500
1.500
1.563
1.563
1.625
1.625

Cable Acceptance
Outer Sheath ‘E’
Min
Max
0.1250
0.2500
0.2500
0.3750
0.3750
0.5000
0.5000
0.6250
0.6250
0.7500
0.7500
0.8750
0.8750
1.0000
0.6250
0.7500
0.7500
0.8750
0.8750
1.0000
1.0000
1.1880
1.1880
1.3750
1.0000
1.1880
1.1880
1.3750
1.3750
1.6250
1.6250
1.8750
1.8750
2.1880
2.1880
2.5000
1.8750
2.1880
2.1880
2.5000
2.5000
3.0000
3.0000
3.5000
2.5000
3.0000
3.0000
3.5000

Gland Length
‘F’ (less entry)
1.375
1.375
1.375
1.375
1.750
1.750
1.750
1.750
1.750
1.750
2.375
2.375
2.375
2.375
3.250
3.250
3.250
3.250
3.250
3.250
4.250
4.250
4.250
4.250

All dimensions in inches unless otherwise noted.

94

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

External
Diameter ‘G’
1.281
1.281
1.281
1.281
1.781
1.781
1.781
1.781
1.781
1.781
2.250
2.250
2.250
2.250
3.250
3.250
3.875
3.875
3.875
3.875
5.500
5.500
5.500
5.500

NCG and NCGB

cULus Listed
NEMA 3, 4X (NCGB only)

4F

North American Standards General Purpose

4F

Gland Type:
Non-armoured

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• cULus Listed - UL File E23223

SELECTION TABLE
Entry Thread Size ‘A’
NPT Size
NPT Catalog #
3
/8"
NCG38 35
1
/2"
NCG50 50
3
/4"
NCG75 75
1"
NCG100 100

NCG Features:
Outer Sheath ‘E’
Min
Max
0.10
0.35
0.20
0.50
0.35
0.75
0.55
1.00

• Standard material is polyamide 6
• Weatherproof seal on outer sheath of cable
• Standard neoprene seal suitable for use in operating temperatures
-25° to 40°C
• Available with NPT threads

All dimensions in inches unless otherwise noted.

POLYAMIDE LOCK NUT
SELECTION TABLE
Size
3
/8"

Catalog #
10N

/2"

11N

3

/4"

12N

1"

13N

1

Gland Type:
Non-armoured

Cable Type:
Non-armoured and tray cable

Certifications and Compliances:
• cULus Listed - UL File E23223
• NEMA 3, 4X

NCGB Features:

SELECTION TABLE
NPT
Size
1
/2"
1
/2"
3
/4"
3
/4"
1"
1"

NPT
Catalog #
NCGB1231
NCGB1232
NCGB2233
NCGB2234
NCGB3235
NCGB3236

Cable
Acceptance
Range 'E'
Min
Max
0.25
0.42
0.40
0.57
0.54
0.68
0.64
0.78
0.76
0.91
0.89
1.03

Gland Length
(Less Entry)
'F'
2.25
2.25
2.52
2.52
3.19
3.19

External
Diameter
'G'
1.33
1.33
1.58
1.58
2.02
2.02

•
•
•
•
•

Standard material is thermoplastic polyester
Tightens by hand to create a watertight seal
Gasket on entry threads included
Compact design allows close grouping of connectors
Available with NPT threads

All dimensions in inches unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

95

Accessories – A Series

4F

4F

A Series – Lock Nut

– Standard material is nickel-plated brass

METRIC SELECTION TABLE

NPT SELECTION TABLE

Entry Thread

A

B

Catalog #

Entry Thread

A

B

Catalog #

M16
M20
M25
M32
M40
M50
M63
M75
M90
M110

3
4
4
4.5
4.5
4.7
6.4
6.4
8
12

19
24
30
36
46
65
80
95
110
130

CAP221694
CAP222094
CAP222594
CAP223294
CAP224094
CAP225094
CAP226394
CAP227594
CAP229094
CAP221104

/ 2"
3
/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"

3.75
4
4.75
5.25
5.75
6.25
9
10

25.4
33
40
50
55.9
70
90
105

CAP280124
CAP280134
CAP280144
CAP280154
CAP280164
CAP280174
CAP280184
CAP280194

1

* For stainless steel replace last digit with "9".

A Series – Sealing Washer – Standard material is neoprene
METRIC SELECTION TABLE
NPT SELECTION TABLE
Metric Metric
Size
Catalog #

Metric
Diam.
‘D’

Metric
Thickness
‘E’

10
12
16
20
25
32
40
50
63
–
–

15.0
18.0
22.0
24.0
30.0
42.0
52.0
63.0
77.0
–
–

1.2
1.2
1.2
1.2
1.5
1.5
1.5
1.5
2.0
–
–

CAP221049
CAP221249
CAP221649
CAP222049
CAP222549
CAP223249
CAP224049
CAP225049
CAP226349
–
–

NPT
Size

NPT
Catalog #

NPT
Diam.
‘D’

NPT
Thickness
‘E’

/4"
/8"
/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"

CAP229014
CAP229038
CAP229012
CAP229034
CAP229010
CAP229114
CAP229112
CAP229020
CAP229212
CAP229300
CAP229312

20.0
22.0
27.0
33.0
41.0
52.0
57.0
71.0
85.0
104.0
120.0

1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0

1
3
1

A Series – Earth Tag – Standard material is nickel-plated brass
METRIC SELECTION TABLE
Entry Thread

A

B

C

D

Catalog #

M16
M20
M25
M32
M40
M50
M63
M75

48.75
53.8
61.5
73
86.5
111.5
125.5
137.5

30
33
36
41
44.5
58
67
73

6.75
7
10.5
12.2
13.5
13.5
13.5
13.5

24.5
28.6
34
42
54
67
77
89

CAP567034
CAP567054
CAP567074
CAP567094
CAP567124
CAP567154
CAP567184
CAP567194

NPT SELECTION TABLE
Entry Thread

A

B

C

D

Catalog #

/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"

61.5
73
73
86.5
111.5
125.5
137.5

36
41
41
44.5
58
67
73

10.5
12.2
12.2
13.5
13.5
13.5
13.5

34
42
42
54
67
77
89

CAP567064
CAP567084
CAP567104
CAP567134
CAP567154
CAP567174
CAP567194

1

All dimensions in millimeters unless otherwise noted.

96

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Accessories – A Series

4F

A-Series – Shroud

– Standard material is stainless steel

– Standard material is PVC

4F

A Series – Serrated Lock Washer

SELECTION TABLE
SELECTION TABLE
Metric Size

External Diameter

Catalog #

16
20
25
32
40
50
63
75
90

25.5
32.5
39.5
49.5
64.5
80.5
100
112
123

CAP280069
CAP280029
CAP280259
CAP280329
CAP280409
CAP280509
CAP280639
CAP280759
CAP280099

Gland Size

Catalog #

4
5
6
7
8
9
10
11
12
13
14
15
16

CAP506040
CAP506050
CAP506060
CAP506070
CAP506080
CAP506090
CAP506100
CAP506110
CAP506120
CAP506130
CAP506140
CAP506150
CAP506160

A Series – Clamping Module
– Standard materials are nickel-plated brass body with stainless steel screws and washers

SELECTION TABLE
Cable Range Gland Size

Across Flats

Width

Thickness Catalog #

4-8.5
6-11
8.5-16
12-21
16-27.5
21-34
27-41
33-48
40-56
47-65
54-74
63-83
72-93

15
19
24
30
41
48
55
64
72
85
95
110
120

18
22
27.5
33.5
45
52
59
69
78
92
103
118
128

5
5
6
8
8
9.5
9.5
12
12
16
16
18
18

4
5
6
7
8
9
10
11
12
13
14
15
16

CAP810434
CAP810534
CAP810634
CAP810734
CAP810834
CAP810934
CAP811034
CAP811134
CAP811234
CAP811334
CAP811434
CAP811534
CAP811634

A Series – Earthing Washer – Standard material is brass
METRIC SELECTION TABLE
Lead Sheath Sealing Range
Gland Size

Min

Max

Cable
Diameter

Catalog #

5
6
7
8
9
10
11
12
13
14
15
16

4
6
9
12
16
21
28
33
40
46.5
54
63

7.5
11
15
20
26.5
32.5
39.5
46.5
54.5
61
72.5
81.5

10
13.9
18.3
23.8
31
38.3
45.3
52.8
60.8
71
80.5
89.5

CAP560530
CAP560630
CAP560730
CAP560830
CAP560930
CAP561030
CAP561130
CAP561230
CAP561330
CAP561430
CAP561530
CAP561630

All dimensions in millimeters unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

97

Accessories – A Series

4F

4F

Standard material is nickel-plated brass
A Series – Adaptors and Reducers – ATEX
Exe Exd with LCIE 98 ATEX 00010

METRIC x METRIC SELECTION TABLE
Female →
Male

M12

M12
M16
M20
M25
M32
M40
M50
M63
M75
M90
M110

M16

M20

M25

M32

M40

M50

M63

M75

M80

M90

M110

745334
745834
745844

740274
740024
740034

740544
740294
740304

740814
740564
740574

741084
740834
740844

741354
741104
741114

741624
741374
741384

741894
741644

745394
745864

METRIC x NPT SELECTION TABLE
Female →
Male

/4"

/8"

1

/2"

3

M12 744104
M16
M20 744204
M25
M32
M40
M50
M63
M75
M90
M110

/4"

1

744194
744214

1"

11/4"

745234
745244
745254
745264

745504
745514
745524

3

744694
744704
744714
744724

744964
744974
744984
744994

11/2"

745774
745784
745794

2"

21/2"

3"

746044
746054
746064

746314
746324

31/2"

746584
744304

Size available – no part number
Size not available

NPT x METRIC SELECTION TABLE
Female →
Male
1
/4"
3
/8"
1
/2"
3
/4"

M12

M16

740614
740884
740914

740624
740894
740194
740204

1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

M20
740904
740454
740464
740474

M25

740714
740724
740734
740744

M32

M40

M50

740984
740994
741004
741104

741264
741274
741284

741524
741534
741544
741554

M63

741794
741804
741814
741824

M75

M90

M100

M110

3"

31/2"

4"

742064

NPT x NPT SELECTION TABLE
Female →
Male
1
/4"
3
/8"
1
/2"
3
/4"

/4"

1

/8"

3

/2"

1

/4"

1"

3

11/4"

11/2"

2"

21/2"

744624

745574
745594

745134
744884
744894

1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

745404
745154
745164

745674
745424
745434

745944
745694
745704

746214
745964

746484
746234
746244

746504

* For stainless steel replace last digit with "9".

98

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Accessories – A Series

4F

4F

A Series – Stopping Plug – Standard material is nickel-plated brass;
ATEX Exe Exd with LCIE 98 ATEX 00010

METRIC SELECTION TABLE
Metric
Size

Metric Catalog #*

Across Flats
‘A’

Hex Thickness
‘B’

Thread Length
‘E’

12
16
20
25
32
40
50
63
75
80
90
100

CAP190124
CAP190164
CAP190204
CAP190254
CAP190324
CAP190404
CAP190504
CAP190634
CAP190754
CAP190804
CAP199904
CAP191004

14
18
23
28
36
44
54
67
80
85
95
110

2.8
3.0
3.0
3.5
4.0
4.0
5.0
5.5
6.0
7.0
8.0
10.0

15
15
15
15
15
15
16
17
18
20
22
22

* For stainless steel replace last digit with "9".

NPT SELECTION TABLE
NPT Size NPT Catalog #*

Across Flats ‘A’

Hex Thickness ‘B’

Thread Length ‘E’

/4"
3
/8"
1
/2"
3
/4"

14
18
22
28
36
44
50
64
75
90
110

2.8
2.8
3.0
3.0
3.5
4.0
5.0
5.5
6.0
6.0
10.0

12
12
16
16
20
20
20
20
28
30
32

1

1"
11/4"
11/2"
2"
21/2"
3"
31/2"

CAP190194
CAP109294
CAP190394
CAP190494
CAP190594
CAP190694
CAP190794
CAP190894
CAP190994
CAP191094
CAP191194

All dimensions in millimeters unless otherwise noted.
*For stainless steel replace last digit with "9".

A Series – Nonmetallic Stopping Plug

– Standard material is polyamide 6; ATEX
certified Ex e II with LCIE 97ATEX6007X

Washer and locknut are required for non-threaded holes (not included) see page 96

POLYAMIDE SELECTION TABLE
Metric
Size

Metric
Catalog #*

Across
Flats ‘A’

Hex
Thickness ‘B’

Thread
Length ‘E’

12
16
20
25
32
40
50
63

CAP191127
CAP191167
CAP191207
CAP191257
CAP191327
CAP191407
CAP191507
CAP191637

15
19
23
28
36
44
54
67

4
4
4
5
5.5
5.5
6
6.5

15
15
15
15
15
15
16
17

*For stainless steel replace last digit with "9".

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

99

4F

4F

Accessories – B Series

B Series – Lock Nut – Standard material is brass
NPT SELECTION TABLE

METRIC SELECTION TABLE
Metric Entry Thread

Catalog #

NPT Entry Thread

Catalog #

M16
M20
M25
M32
M40
M50
M63
M75
M80
M85
M90
M100

BLN/M16
BLN/M20
BLN/M25
BLN/M32
BLN/M40
BLN/M50
BLN/M63
BLN/M75
BLN/M80
BLN/M85
BLN/M90
BLN/M100

/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

BLN/050NPT
BLN/075NPT
BLN/100NPT
BLN/125NPT
BLN/150NPT
BLN/200NPT
BLN/250NPT
BLN/300NPT
BLN/350NPT
BLN/400NPT

1

B Series – Sealing Washer – Standard material is nylon
METRIC SELECTION TABLE

NPT SELECTION TABLE

Metric Entry Thread

Catalog #

NPT Entry Thread

Catalog #

M16
M20
M25
M32
M40
M50
M63
M75
M80
M85
M90
M100

RNSW/M16
RNSW/M20
RNSW/M25
RNSW/M32
RNSW/M40
RNSW/M50
RNSW/M63
RNSW/M75
RNSW/M80
RNSW/M85
RNSW/M90
RNSW/M100

/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

RNSW/050NPT
RNSW/075NPT
RNSW/100NPT
RNSW/125NPT
RNSW/150NPT
RNSW/200NPT
RNSW/250NPT
RNSW/300NPT
RNSW/350NPT
RNSW/400NPT

1

B Series – Earth Tag – Standard material is brass
NPT SELECTION TABLE

METRIC SELECTION TABLE
Metric Entry Thread

Catalog #

NPT Entry Thread

Catalog #

M16
M20
M25
M32
M40
M50
M63
M75
M80
M85
M90
M100

BET/M16
BET/M20
BET/M25
BET/M32
BET/M40
BET/M50
BET/M63
BET/M75
BET/M80
BET/M85
BET/M90
BET/M100

1

/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

BET/050NPT
BET/075NPT
BET/100NPT
BET/125NPT
BET/150NPT
BET/200NPT
BET/250NPT
BET/300NPT
BET/350NPT
BET/400NPT

B Series – Shroud
PCP SELECTION TABLE

PVC SELECTION TABLE
Size (Gland Size)

Catalog #

Size

Catalog #

L24 (16, 20s)
L30 (20)
L38 (25)
L46 (32)
L55 (40)
L65 (50, 50s)
L80 (63, 63s)
L90 (75, 75s)
L104 (80,85)
L114 (90, 100)

PVC-L24
PVC-L30
PVC-L38
PVC-L46
PVC-L55
PVC-L65
PVC-L80
PVC-L90
PVC-L104
PVC-L114

L24 (16, 20s)
L30 (20)
L38 (25)
L46 (32)
L55 (40)
L65 (50, 50s)
L80 (63, 63s)
L90 (75, 75s)
L104 (80, 85)

PCP-L24
PCP-L30
PCP-L38
PCP-L46
PCP-L55
PCP-L65
PCP-L80
PCP-L90
PCP-L104
PCP

All dimensions in millimeters unless otherwise noted.

100

www.crouse-hinds.com

US: 1-866-764-5454

PVC

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4F

Accessories – D Series

4F

D Series – Lock Nut

– Standard material is polyamide

SELECTION TABLE
Metric Entry Diameter

Width

Thickness

Catalog #

M12
M16
M20
M25
M32
M40
M50
M63

17.00
22.00
26.00
32.00
41.00
50.00
60.00
75.00

5.00
5.00
6.00
6.00
7.00
7.00
8.00
8.00

GHG
GHG
GHG
GHG
GHG
GHG
GHG
GHG

x
x
x
x
x
x
x
x

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

D Series – Reducing Ring

960
960
960
960
960
960
960
960

1941
1941
1941
1941
1941
1941
1941
1941

R0031
R0032
R0033
R0034
R0035
R0036
R0037
R0038

– Standard material is polyamide

SELECTION TABLE
Thread 1 Thread 2

Length 1

Length 2

Length 3

Across
Flats

Catalog #

20
25
32
32
40
40
50
50
63
63

12.00
14.00
16.00
16.00
16.00
16.00
18.00
18.00
18.00
18.00

8.00
8.00
10.00
10.00
10.00
10.00
12.00
12.00
12.00
12.00

8.00
8.00
6.00
10.00
8.00
10.00
10.00
10.00
10.00
12.00

24.00
29.00
36.00
36.00
46.00
46.00
55.00
68.00
68.00
68.00

GHG
GHG
GHG
GHG
GHG
GHG
GHG
GHG
GHG
GHG

x
x
x
x
x
x
x
x
x
x

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

M16
M20
M20
M25
M25
M32
M32
M40
M40
M50

x
x
x
x
x
x
x
x
x
x

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

D Series – Screw Plug

960
960
960
960
960
960
960
960
960
960

1946
1946
1946
1946
1946
1946
1946
1946
1946
1946

R0071
R0072
R0056
R0074
R0059
R0077
R0062
R0080
R0065
R0083

– Standard material is polyamide

SELECTION TABLE
Thread 1

Diameter

Length 1

Length 2

Catalog #

16
20
25
32
40
50
63

21.50
25.50
30.50
37.50
45.50
55.50
85.00

4.00
4.00
4.00
5.50
5.50
5.50
6.50

12.00
13.00
13.00
15.00
15.00
16.00
16.00

GHG
GHG
GHG
GHG
GHG
GHG
GHG

x
x
x
x
x
x
x

1.5
1.5
1.5
1.5
1.5
1.5
1.5

D Series – Blanking Plug

960
960
960
960
960
960
960

1952
1952
1952
1952
1952
1952
1952

R0111
R0112
R0113
R0114
R0115
R0116
R0117

– For sealing unused cable glands;
Standard material is polyamide

SELECTION TABLE
Thread 1

Diameter

Length 1

Catalog #

12
16
20
25
32
40
50
63

6.00
7.00
8.50
11.00
14.00
20.00
26.00
34.00

30.30
33.00
34.50
36.00
39.50
42.00
44.00
45.00

GHG
GHG
GHG
GHG
GHG
GHG
GHG
GHG

960
960
960
960
960
960
960
960

1944
1944
1944
1944
1944
1944
1944
1944

R0101
R0102
R0103
R0104
R0105
R0106
R0107
R0108

All dimensions in millimeters unless otherwise noted.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

101

4F

4F

Accessories – E Series

E Series – Chico® LiquidSeal
SELECTION TABLE
Std. Carton Qty.

Size (ml.)

Catalog #

10
10
5

10 ml.
20 ml.
50 ml.

LSC 10
LSC 20
LSC 50

E Series – TSC Epoxy Sealing Compound
SELECTION TABLE
Std. Carton Qty.

Tube Size

Catalog #

10
10
5

0.5 oz.
1.0 oz.
4.0 oz.

TSC05
TSC1
TSC4

E Series – Wire Mesh Grip
SELECTION TABLE
Cord Range Diameter

Gland Nut

Wire Mesh Grip Catalog #

.375 to .500
.500 to .625
.500 to .625
.625 to .750
.750 to .875
.875 to 1.000
.875 to 1.000
.875 to 1.000
.875 to 1.000
1.000 to 1.188
1.188 to 1.375
1.375 to 1.625
1.625 to 1.875

NUT94
NUT94
NUT95
NUT95
NUT95
NUT98
NUT98
NUT95
NUT98
NUT98
NUT98
NUT913
NUT913

RPE417-115
RPE417-116
RPE417-129
RPE417-117
RPE421-119
16676N
16676N
RPE421-120
16676N
RPE421-121
RPE433-122
RPE433-123
17317N

E Series – Cold Shrink™ Kit
SELECTION TABLE
Entry Thread

Catalog #

/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

TMC-K1
TMC-K2
TMC-K3
TMC-K4
TMC-K5
TMC-K6
TMC-K7
TMC-K8
TMC-K9
TMC-K10

1

All dimensions in inches unless otherwise noted.

Cold Shrink™ Corrosion Protection Kits are specially designed for Eaton's Crouse-Hinds TMC, TMCX, and TECK fittings to provide protection
against corrosive elements like salt spray and moisture. The TMC-K kit is made of a Cold Shrink material that is quick and easy to install on
the gland. The Cold Shrink material is made of EPDM rubber that contains no chlorides or sulfurs. The protection kit installs easily over the
gland without the use of a heat source to shrink the material tightly over the seal. The Cold Shrink material can be removed easily from the
gland by simply cutting it off. See ordering information for complete offering of TMC-K Cold Shrink kits for corrosion protection. Cold Shrink
is a registered trademark of the 3M Company.

102

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4F

Accessories – Breathers & Drains

4F

Breather Drain – SIRA 99 ATEX 3050 U

I M2 II, 2GD, EExe I & II (Stainless steel & brass only)
II 2GD, EExe II (Nylon only)
Enclosure type 4X IP66

SELECTION TABLE
Entry Thread

Material

Catalog #

M20
M20
M20
M25
M25
M25
1
/ 2”
1
/ 2”
3
/ 4”
3
/ 4”

Brass
Stainless
Nylon
Brass
Stainless
Nylon
Brass
Stainless
Brass
Stainless

DPE1004S3
DPE3004S3
DPE4004S3
DPE1005S3
DPE3005S3
DPE4005S3
DPE1029S3
DPE3029S3
DPE1030S3
DPE3030S3

Steel
Steel
Steel
Steel

Drainage Plug – Standard material is polyamide; PTB01 ATEX 1128X Ex 1126 Exe II
SELECTION TABLE
Thread 1

Diameter

Length 1

Length 2

Catalog #

M25 x 1.5

30.00

19.00

4.50

GHG 960 1927 R0105

Breathing and Drainage Plug – Standard material is glass-filled polyamide;
SIRA 99 ATEX 3050 U Ex 1126 Exe II

SELECTION TABLE
Thread 1

Catalog #

M25 x 1.5

GHG 960 1954 R0002

All dimensions in millimeters unless otherwise noted.

Please refer to section 6F for additional breather and drain options.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

103

LCC Series Cable Tray
Conduit Clamps

4F

4F

Applications:

LCC

LCCF

LCC cable tray conduit clamps are used for installation on cable tray
side rails with inside flanges (requiring inside tray mounting) and
outside flanges; LCCF clamps are for use exclusively on inside
flanges.
LCC/LCCF cable tray conduit clamps:
• Provide a means of clamping metal conduit (rigid steel or
aluminum, IMC and EMT) to cable tray to provide for the exit of
power and/or control cables from tray
• Provide a means to firmly bond exit conduit to cable tray for best
grounding continuity
• Provide strong mechanical support for exit conduits and cables
• Can be used indoors or outdoors, wherever cable tray systems are
installed
• Facilitate the safe exit of cables from tray – insure protection of
cables from damage

For use with outside rail tray

Ordering Information
Conduit Size

Cat. #

Cat. #

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

LCC1
LCC2
LCC3
LCC4
LCC5
LCC6
LCC7
LCC8
LCC9
LCC010

LCCF1
LCCF2
LCCF3
LCCF4
LCCF5
LCCF6
LCCF7
LCCF8
LCCF9
LCCF010

1

Features:
• Quick and easy installation – low installed cost. Merely tighten
clamp nut and/or set screw(s)
• Swivel hook clears conduit. No disassembly required for
installation
• No drilling or welding necessary for installation
• Provides superior ground continuity between conduit and cable
tray

For use with inside rail tray

Dimensions

• Clamps conduit at any angle with relation to tray – facilitates wire
pulling, minimizes conduit bending

In Inches:

• Malleable iron body provides great strength
• Knurled body has no-slip surface for conduit and tray – positive
grip assured
• Compact design has low profile – minimum tray space required for
assembly
• Design accommodates all popular types of cable tray
• Accommodates wide range of conduit sizes – 1/2" through 4"
LCCF features:
• Outside mounting facilitates inside rail installation
• Adjustable hook assures positive grip on inside rail
• Accommodates 3/4" through 13/4" wide flange

Certifications and Compliances:
• UL Standard: 467 (Grounding and Bonding Equipment)

Standard Materials:
• Body – cast iron
LCC

• Hook – steel

LCCF

• Set screws and clamping nut – steel
• Hook cap – vinyl

• Cast iron – electrogalvanized and aluminum acrylic paint
• Steel – zinc electroplate
• Vinyl – natural

Conduit Size Ranges:
• 1/2" to 4"

www.crouse-hinds.com

LCC
a

b

LCCF
a

b

c

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

33/16
37/16
39/16
4
413/16
55/16
513/16
613/16
75/16
713/16

111/16
111/16
111/16
111/16
211/16
211/16
211/16
33/4
33/4
33/4

31/8
311/32
319/32
315/16
43/4
51/4
53/4
63/4
71/4
73/4

15/8
15/8
15/8
15/8
23/4
23/4
23/4
311/16
311/16
311/16

111/32
111/32
111/32
111/32
111/16
111/16
111/16
23/16
23/16
23/16

1

Standard Finishes:

104

Conduit Size

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

TGC Cable Tray Ground Conductor Clamp

4F

Ordering Information

Cable tray grounding conductor clamps
are designed for use in heavy industrial
applications:
• To provide a means for securely
attaching a grounding conductor to
cable tray to maintain grounding
continuity for the entire cable tray
system
• To provide protection of equipment
through a reliable method for carrying
ground fault currents
• To meet UL and NEC Code
requirements
• For installation indoors or outdoors, with
most types of cable trays with inside or
outside flanges

Ground Wire Size

Cat. #

#6 to 2/ 0

TGC40

4F

Applications:

TGC Clamp installs on cable trays with
inside or outside flanges

Features:
• Meets requirements of NEC Code Article
318-7 for grounding and bonding

Dimensions
In Inches:

• Quick and easy installation – low
installed cost. No drilling or special tools
required.
• Accommodates solid (where suitable) or
stranded aluminum or copper grounding
conductors in sizes from #6 to 2/0
• Set screw bonds the clamp to the tray
and another set screw securely attaches
the grounding conductor to the clamp –
outstanding pull-out and vibration
resistance
• Design accommodates most popular
types of cable tray
• Mechanical device – can be easily
inspected
• Malleable iron body provides high
strength

Certifications and
Compliances:
• UL Standard: 467 (Grounding and
Bonding Equipment)

Standard Materials:
• Body – malleable iron
• Set screws – steel

Standard Finishes:
• Malleable iron and steel –
electrogalvanized

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

105

4F

4F

TW Series THRU-WALL BARRIER®
Cable/Conduit Sealing Device

Applications:
THRU-WALL BARRIER cable/conduit sealing device is used
wherever there is a need to seal cables or conduits penetrating fireor non-fire-rated walls, ceilings, floors, bulkheads or decks. For nonfire-rated walls, ceilings, floors, bulkheads or decks, THRU-WALL
BARRIER also restricts water and dust and will help contain treated
air. THRU-WALL BARRIER is designed:
• To provide a seal for cable/conduit penetrations through masonry,
concrete or steel; to restrict the entrance of contaminants through
cable/conduit penetrations into clean areas
• For use with most types of power, instrument and control cables
as well as conduits
• To be used indoors or outdoors, in new construction or existing
structures

Certifications and Compliances:
•
•
•
•
•

Features:
System
• Few parts required to seal a wide range of diameters of cables or
conduits

ASTM Standard E-119
NFPA 251
UL Classification per UL Standard 1479
USCG Acceptance – consult Eaton's Crouse-Hinds
NAVSEA Approval – Electric Plant Installation Standard Methods
No. S9300- AW-EDG-010/EPISM – TWFS/TWBS assemblies

• Easy and fast installation, using factory assembled components

Standard Materials:

• High degree of flexibility with interchangeable sealing block
assemblies and a selection of different sizes of frames
Mounting frame
• One-piece cast malleable iron or steel mounting frame can be cast
into concrete during wall construction, grouted in masonry
surfaces or welded into steel bulkheads at any time
• Retrofit frame allows for easy installation of frame where
cables/conduit are already installed
• Available in sizes to accommodate a wide range of cable tray sizes
and loadings, including single and multiple layers of cables for
power or instrument applications
• Cast keyways in mounting frame align and position sealing block
assemblies
• Frames can be installed in wall such that sealing block assemblies
can be inserted in either horizontal or vertical position

• Mounting frame:
TWF, TWFR – cast malleable iron
TWFS – cast carbon steel,
ASTM A27 Grade 60-30
• Pressure plate – cast malleable iron
• Sealing material – special elastomeric material
• Clamping hardware – steel

Standard Finishes:
• Malleable iron and hardware – electrogalvanized
• Steel – aluminized weldable paint
• Special elastomeric material – natural

Easy three step installation

Sealing block assembly
• Specially formulated elastomeric material between cast malleable
iron pressure plates protects cable from mechanical damage;
provides high pull-out resistance and positive cable separation;
expands during fire to seal any voids left by burned cable
insulation
• Interchangeable sealing block assemblies fit all THRU-WALL
BARRIER mounting frames
• Cast stops on front pressure plate prevent sealing block assembly
from slipping through mounting frame during installation
• Assemblies are offered for all cable/conduit outside diameters
from .250" to 4.500" (6.4 mm to 114.3 mm); cables with diameters
less than .250" can be accommodated – consult Eaton's CrouseHinds

1. Cast, grout or weld the onepiece mounting frame into
masonry or steel surface.

• Sealing block openings will accommodate undersize and
out-of-round cable
• Each sealing block assembly seals multiple cables/conduits;
compact design permits close nesting of cables, saving space
• Reducers permit sealing block assemblies to accept cables with
smaller O.D. than the specified range
• Plugs are used to fill unused openings in sealing block assemblies;
blank sealing block assemblies fill unused spaces in mounting
frames, providing for future expansion

106

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

3. Position cables/conduit,
insert factory assembled
sealing blocks into keyways in
mounting frame, and tighten
nuts on clamping hardware to
effect the seal.

Copyright© 2013 Eaton’s Crouse-Hinds Business

2. Feed cables/conduit
through the frame.

4F

TW Series THRU-WALL BARRIER®
Cable/Conduit Sealing Device
Sealing Block Assemblies & Mounting Frames
Ordering Information

TWB sealing block assemblies are offered
for cable/conduit outside diameters (O.D.)
from .250" to 4.500" (6.4 mm to 114.3
mm). Cables with diameters less than
.250" can be accommodated – consult
Eaton's Crouse-Hinds. Each assembly
opening will accommodate a .250"
(6.4 mm) O.D. range. When clamping
hardware is tightened, the elastomeric
material is uniformly compressed around
all cable/conduits for a completely tight fit.

Opening
Size
Range
No. Openings
In Block

In. .250–.500
mm 6.4–12.7
11

4F

TWB Sealing Block Assemblies
Sealing block assemblies are offered for
use in marine applications. Each assembly
has the required lubrication and sealing
gaskets to meet U.S. Navy Hydrostatic
Pressure Test Requirements. Assemblies
for marine applications are available for
cable/conduit outside diameters (O.D.)
from .250" (6.4 mm) through 3.500"
(88.9 mm). To order, add suffix S to TWB
sealing block assembly Cat. No. Example:
TWBS4036.

TWB2063
Depending on opening size range, a
standard sealing block assembly will
seal from one to eleven cables

.500–.750 .750–1.000 1.000–1.250 1.250–1.500 1.500–1.750 1.750–2.000 2.000–2.250 2.250–2.500
12.7–19.1 19.1–25.4

11
11
6
6
Added*
Added*

25.4–31.8

31.8–38.1

38.1–44.5

44.5–50.8

50.8–57.2

57.2–63.5

5

4

3

3

3

2

Sealing
Block
Assembly
Cat. #
Frame
Spaces
Required

TWB2111

TWB2062

TWB1111

TWB2112 TWB2063

TWB3054

TWB3045

TWB30355

TWB4036

TWB40366

TWB5027

2

2 2

3

3

3

4

4

5

Plug Cat. #

TWP1

Reducer
Cat. # §

—

1

2
TWP3

TWR2

TWR3

TWP5
TWR4

TWP6

TWR5

TWR55

TWR6

TWP7
TWR66

TWR7

TWF Mounting Frames
TWF(S) mounting frames may be installed
either horizontally or vertically. TWFR retrofit
frames are used wherever cables/conduits
are already installed through a fire- or nonfire-rated wall, floor or ceiling. They are
designed with a removable section to permit
installation around cables/conduits. TWFR
retrofit frames can be grouted into walls,
floors, or ceilings, or welded into steel
bulkheads or decks. TWFR retrofit frames
will perform in the same manner as the onepiece TWF(S) frames.
TWFS steel mounting frames are welded
directly into steel bulkheads, decks and
prepared sleeves. For marine applications,
keeper bars are provided to securely hold
TWBS sealing block assemblies in position
when installed.

TWF6

TWFS10

TWF10

TWF12
No. of Spaces
Available

Frame Cat. #

Retrofit
Frame Cat. #

6
10
12
20
24
30

TWF6
TWF10
TWF12†
TWF20
TWF24
TWF30

TWFR6
TWFR10
TWFR12†
TWFR20
TWFR24
TWFR30

Cast Steel
Frame Cat. #
TWFS10
TWFS20
TWFS30

†Includes removable partition.

†For 3.5" - 4" cable/conduit – use TWB7011010 assembly and reduce down using TWR reducers.
*Catalog # TWB1111 and TWB2112 are used between TWB2111 and TWB2062 in cases where the number of cables to be sealed in .250-.750 range exceeds the number of openings in
standard assemblies. Use as many of these higher density assemblies as needed, sandwiched between halves of a standard assembly.
§TWR reducers match TWB sealing block assemblies shown in column above Cat. No. and reduce openings to accept cable size ranges shown in adjacent column to the left (in direction of
arrow).

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

107

TW Series THRU-WALL BARRIER®
Cable/Conduit Sealing Device

4F

4F

Plugs, Reducers, Closure Cover Kits, Anchors & Lubricant
Ordering Information

TWB2112

TWP Plugs

TWR Reducers

TWP plugs will close any unused openings
in sealing block assemblies. See table for
plug catalog numbers which match
specific sealing block assemblies.

TWR reducers will reduce openings by
.250" (6.4 mm) in sealing block
assemblies. See table for reducer catalog
numbers which match specific sealing
block assemblies. More than one reducer
can be used in a single opening.

TWB2062

It is possible to increase cable fill density with double-sided sealing block assemblies (TWB1111 and TWB2112) sandwiched between halves
of a standard assembly.
2.500–2.750

2.750–3.000

3.000–3.250

3.250–3.500

3.500–4.250†

4.250–4.500

63.5–69.9

69.9–76.2

76.2–82.6

82.6–88.9

101.6–108.0

108.0–114.3

Blank – No
Openings

2

2

2

2

1

1

None

None

TWB50277

TWB5028

TWB60288

TWB6029

TWB7011010

TWB70111

TWB1

TWB3

5

6

6

7

7

1

3

TWP8

TWP9

TWP10

TWP11

—

TWR8

TWR88

TWR9
TWR99

TWR1010
TWR10

TWR11

—

5
TWP7
TWR77

TWB Closure Cover Kits

TWK Anchors

TWB closure cover kits offer an optional method to close TWF
frames installed for future expansion or those that are abandoned.
Closure cover kits include two covers clamped to opposite sides of
the frame with hardware provided. The insulating material provided is
sandwiched between the two covers to maintain the fire rating of the
assembly. See table below for closure kit catalog numbers.

TWK anchor assemblies are used to attach mounting frames to wall,
ceiling or floor when grouting in frames.

No. of
Spaces
Available

Closure
Cover Kit
Cat. #*

6
10
12
20
24
30

TWB600‡
TWB1000
TWB600‡
TWB2000
TWB2400
TWB3000

Mounting Type

Cat. #

Flush
Recessed

TWK1
TWK2

*TWB closure cover kits are not designed to provide a
watertight seal in marine/shipboard applications or
washdown areas. One kit seals one unused frame
opening of same size. Example: use one TWB2000 kit to
seal one TWF20, or TWFR20 frame.
‡Use two TWB600 kits to seal one TWF12 or TWFR12
frame opening.

108

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

TW Series THRU-WALL BARRIER®
Cable/Conduit Sealing Device

4F

Ordering Example A
Specifying & Ordering

Selecting and specifying THRU-WALL
BARRIER components is a simple
procedure. Primary components for the
THRU-WALL BARRIER consist of TWF
mounting frames in various sizes and TWB
sealing block assemblies for cable/conduit
outside diameters (O.D.) in 1/4-inch
increments from .250" to 4.500" (6.4 mm
to 114.3 mm). Cables with diameters less
than .250" can be accommodated –
consult Eaton's Crouse-Hinds.

The selection of components is based on
the quantity and sizes of cables or
conduits going through the penetrations.
Once these are known, the sealing block
assemblies and frames can be selected.

Cable/conduit sizes can be mixed within a
sealing block assembly by inserting TWR
reducers to accommodate smaller
diameters. The use of reducers can
decrease the number of sealing block
assemblies required. More than one
reducer can be used in a single opening.
Another way to increase density is to use
TWB1111 and TWB2112 sealing block
assemblies wherever there is a large
number of cables/conduits in sizes ranging
from .250" to .750".
TWB2112

4F

Product Information

Specify TWR reducers to accommodate
smaller diameter cables where possible
and TWP plugs to fill openings not used.
Step 4. Total the frame spaces required for
the specified sealing block assemblies and
select an appropriate mounting frame(s).
Frames are available in 6-, 10-, 12-, 20-,
24- and 30-space sizes. Keep future
expansion requirements in mind when
specifying frame. Specify blank sealing
block assemblies to fill unused mounting
frame space and TWB closure cover kits
to fill unused frames.

Step 1. Group cables/conduits by outside
diameter (O.D.) and rank from the largest
to the smallest.
Step 2. Keeping in mind that sealing block
assemblies are available in one-quarter
inch increments, group cables/conduits
that fall within the same sealing block
assembly O.D. size range.

Step 5. Check specification/order to be
sure it includes 1) frames, 2) sealing block
assemblies, 3) plugs and 4) reducers.

Step 3. Starting with the largest cable/
conduit O.D., select the sealing block
assemblies required. All openings in each
sealing block assembly must be filled.

Ordering Example A:
Cable tray size: 24"

diameter cables where possible and
TWP plugs to fill openings not used.
(See Example A diagram.)

Cables specified: 5 power cables – sizes
ranging from 1.960" to 2.200" O.D.

Note: In the example, one TWR66 reducer is required to
accommodate the cable with 1.960 O.D. and one TWP6
plug is required for the unused opening.

Spare capacity required: 50%
Step 1. Group cables by O.D. and rank
from largest to smallest.
Cable
Cable Qty.
O.D.

Step 4. Total the frame spaces required for
sealing block assemblies and select
appropriate size mounting frame. Factor in
spare capacity required for future
expansion.

4
2.200
1
1.960
Total
5
Step 2. Group cables that fall within the
same sealing block assembly size.
Sealing Block
Cable Qty.
O.D. Range
TWB2062

TWB2062

Shown here is a double-sided sealing
block assembly (TWB2112) sandwiched
between halves of a standard sealing
block assembly (TWB2062). Additional
double-sided sealing block assemblies
may be used to accommodate larger
quantities of cables or conduits.
Unused sealing block openings must be
closed with TWP plugs. Blank sealing
block assemblies TWB1 and TWB3 are
used to fill each unused space in the
mounting frame and permit future
expansion of the system. Typical practice
is to include space allowance of 20 to
50% for future expansion. TWB closure
kits are used to seal entire frames and
permit future system expansion.

Total frame spaces required
Specification requires 50%
spare capacity
Total spaces

TWB40366
TWB40366

4
12

Selection: One TWF12 mounting frame
with capacity of 12 spaces. Four TWB1
blank sealing block assemblies to fill
unused frame space. (Choice of frame
could vary based on future expansion
needs and/or specific cable arrangement.)

4
2.000–2.250
1
1.750–2.000
Total 5
Step 3. Starting with the largest cable
O.D., select the quantity of sealing
block assemblies required. Specify
TWR reducers to accommodate smaller
Sealing Block
Assy Cat. #

8

O.D. Range

Number of
Openings

Cables to
be Sealed

Number of
Openings

Cables to
be Sealed

2.000–2.250
2.000–2.250
Totals

3
3
66

3
2
5

—
1
1

4
4
8

Step 5. Bill of materials for
specification/order should read:
(1) TWF12
(2) TWB40366
(4) TWB1
(1) TWR66
(1) TWP6

Example A diagram
www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

109

TW Series THRU-WALL BARRIER®
Cable/Conduit Sealing Device

4F

4F

Ordering Example B
Dimensions
Ordering Example B:
Cable tray size: 24"
Cables specified: 6 power cables – sizes
ranging from 2.140" to 2.180" O.D. 31
control cables – sizes ranging from .550" to
.945" O.D.
Spare capacity required: 25%
Step 1. Group cables by O.D. and rank
from largest to smallest.
Cable Qty.
Cable O.D.
4
2
1
4
7
9
10
37

Total

2.180
2.140
.945
.890
.700
.637
.550

Step 2. Group cables that fall within the
same sealing block assembly size.
Sealing Block
Cable Qty.
O.D. Range
6
2.000–2.250
5
.750–1.000
26
.500–.750
Total 37
Step 3. Starting with the largest cable O.D.,
select the quantity of sealing block
assemblies required. Specify TWR reducers
to accommodate smaller diameter cables
where possible and TWP plugs to fill
openings not used. (See Example B
diagram.)

Sealing Block
Assy Cat. #

Number of
O.D. Range Openings

TWB40366
TWB40366
TWB2063
TWB2062
TWB2112
TWB2112

2.000–2.250
2.000–2.250
.750–1.000
.500–.750
.500–.750
.500–.750
Totals

3
3
6
6
11
11
40

Note: In this example, two TWB2112 sealing block
assemblies are sandwiched between two halves of a
TWB2062. This dramatically increases cable density in
minimum frame space. One TWP3 plug is required for
unused opening in TWB2063 and two TWP1 plugs are
required for unused openings in the TWB2112.

Step 4. Total the frame spaces required for
sealing block assemblies and select
appropriate size mounting frame(s). Factor
in spare capacity required for future
expansion.
Total frame spaces required
Specification requires 25%
spare capacity
Total

Cables to
be Sealed

Openings
Not Used

Frame Spaces
Required

3
3
5
6
11
9
37

—
—
1
—
—
2
3

4
4
2
2
2
2
16

Step 5. Bill of materials for
specification/order should read:
(2)
TWF10 or (1) TWF20
(2)
TWB40366
(1)
TWB2063
(1)
TWB2062
(2)
TWB2112
(1)
TWP3
(2)
TWP1
(1)
TWB3
(1)
TWB1

16
4
20

Selection: Two TWF10 (or one TWF20)
mounting frames with total capacity of 20
spaces. One TWB3 and one TWB1 blank
sealing block assembly to fill unused frame
space. (Choice of frame could vary based
on future expansion needs and/or specific
cable/conduit arrangement.)
Example B diagram
*For TWFS mounting frame hole dimensions, contact
Eaton's Crouse-Hinds ECM field representative or
headquarters.

Dimensions
In Inches:

110

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

4F

TW Series THRU-WALL BARRIER®
Cable/Conduit Sealing Device
Dimensions*

4F

Dimensions
In Inches:

TWF12 (38 lbs.)

TWF6 (20 lbs.)

TWF10 (25 lbs.)

TWF20 (82 lbs.)

TWB
TWF24 (88 lbs.)

TWK
1. Dimensions are shown as inches (mm).
2. Dimensions shown for TWF frames also apply for TWFR retrofit frames.

TWF30 (97 lbs.)
*For TWF mounting frame hole dimensions, contact Eaton's Crouse-Hinds ECM field representative or headquarters.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

111

4F

Link-Seal® Devices

Wet Locations
Corrosive Environments

4F

Environmental Seal for
Conduit Passing Through
Concrete Walls, Floors, or Ceilings
Link-Seal Devices
Applications:

Environmental Conduit
Seal

• Eaton's Crouse-Hinds Link-Seal® is the
quick, economical way to seal around
conduit in concrete walls, floors and
casings. Link-Seal is a modular
mechanical seal used for any type of
penetration.

Ordering Information:

Features and Benefits:
• Saves time and money – Link-Seal
installs in up to 75% less time than
competition products
• Positive Hydrostatic Sealing – properly
installed, Link-Seal is rated at 20 psig
(40 feet of head), which exceeds the
performance requirements of most
applications
• Environment Seals – Link-Seal
environmental seal is designed for long
life and use as a permanent seal. Seal
elements are specially compounded to
resist aging, ozone, sunlight, water and a
wide range of chemicals
• Fire Seals – for fire protection in floor
and wall penetrations Link-Seal is
Factory Mutual approved
• Resistance to high and low temperatures
– Link-Seal environmental seal is
manufactured from special compounds
that resist temperatures from
–40°F to +250°F. Link-Seal Fire
Seal is manufactured from a silicone
material that resists temperatures from
–67°F to +400°F
• Corrosion protection – where installation
against galvanic corrosion (or
electrolysis) is required, Link-Seal
provides complete separation pipe and
casing. Metal-to-metal contact is
eliminated
• Compensates for misalignment –
Link-Seal allows for some angular and
off-center conduit conditions and still
seals effectively
• Absorbs shock, sound and vibration –
this inherent benefit of Link-Seal helps
reduce conduit failure due to fatigue and
threaded connections

It’s easy. Locate the conduit size and type
you are installing in the columns on the
left. Then locate the seal and sleeve part
numbers under the installation method
you’ve selected. No sleeve is needed for
cored or cast hole installation.

Cored or Cast Hole
Method:
Note the appropriate hole diameter and
select the seal part number. Example:
For 3/ 4" EMT conduit through a cored
hole – Core a 2" diameter hole and install
the conduit using Link-Seal part number
LSA200-C-04.

Sleeve Methods:
Select either the plastic or metal sleeve.
Both types of sleeves are designed to be
cast into concrete walls or floors. Sleeves
are ordered separately. Remember to add
the wall or floor thickness to the steel
sleeve part number to insure the sleeve is
provided in the proper length. Plastic
sleeves are a standard 16 long and can be
modified in the field.

Materials:
The standard product for environmental
conduit seals is made from EPDM supplied
with steel bolts and nuts with a zinc
dichromate finish. These seals are suitable
for use in water, direct ground burial and
atmospheric conditions. They provide
electrical insulation where cathodic
protection is required. EPDM rubber is
resistant to most inorganic acids and
alkalis, and some organic chemicals
(acetone, alcohol, ketones).

Options:
To order the standard product with 316
stainless steel bolts and nuts, for corrosive
environments, replace the "C" in the seal
catalog number with "S316". For example,
a 1/2" seal for rigid steel conduit for a cored
hole is an LSA200-C-04; ordered with
stainless steel bolts and nuts the catalog
number becomes LSA200-S316-04.

Standard Materials:
• Rubber Seal Elements:
EPDM (Black) – Environmental Seals
Silicone (Grey) – Fire Seals
• Pressure Plates:
Glass Reinforced Nylon – Environmental
Seals
Steel w/Zinc Dichromate Plate – Fire Seals
• Fasteners:
Carbon Steel, Zinc Dichromate Plate –
Environmental Seals
316 Stainless Steel – Environmental with
Option S316
Carbon Steel w/Zinc Dichromate – Fire
Seals

112

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Link-Seal® Devices

4F

Wet Locations
Corrosive Environments

Environmental Seal for
Conduit passing through
Concrete Walls, Floors or Ceilings

4F

Ordering Information - Environmental Conduit Seal
Conduit
Nominal
Size

Conduit
Type*

Conduit
Actual O.D.
(inches)

Cast/Cored
Hole Dia.
(inches)

Seal for
Cast/Cored Hole
Cat. #

Plastic
Sleeve
Cat. #

Seal for
Plastic Sleeve
Cat. #

Steel
Sleeve
Cat. #

Seal for
Steel Sleeve
Cat. #

/2"
/2"
/2"

EMT
IMC
RSC

.706
.815
.840

2.000
2.000
2.000

LSA275 C 04
LSA200 C 04
LSA200 C 04

LS CS 2 16
LS CS 2 16
LS CS 2 16

LSA200 C 04
LSA200 C 04
LSA200 C 04

WS2 15 ➀
WS2 21 ➀
WS2 21 ➀

LSA275 C 04
LSA200 C 04
LSA200 C 04

/4"
/4"
/4"

EMT
IMC
RSC

.922
1.029
1.050

2.000
2.500
2.500

LSA200 C 04
LSA275 C 06
LSA275 C 06

LS CS 3 16
LS CS 3 16
LS CS 3 16

LSA315 C 04
LSA315 C 04
LSA315 C 04

WS2 15 ➀
LSA200 C 04
WS2 15 ➀
LSA200 C 04
WS2.5 20 ➀ LSA275 C 06

1"
1"
1"

EMT
IMC
RSC

1.163
1.290
1.315

2.500
3.000
3.000

LSA315 C 04
LSA300 C 04
LSA300 C 04

LS CS 3 16
LS CS 3 16
LS CS 3 16

LSA300 C 04
LSA300 C 04
LSA300 C 04

WS2.5 20 ➀ LSA275 C 06
WS2.5 10 ➀ LSA275 C 06
WS2.5 20 ➀ LSA200 C 05

11/4"
11/4"
11/4"

EMT
IMC
RSC

1.510
1.638
1.660

3.000
3.000
3.000

LSA300 C 04
LSA275 C 07
LSA275 C 07

LS CS 3.5 16 LSA315 C 05
LS CS 3.5 16 LSA300 C 05
LS CS 3 16
LSA200 C 06

WS3.5 22 ➀ LSA315 C 05
WS3.5 22 ➀ LSA315 C 05
WS3.5 22 ➀ LSA315 C 05

11/2"
11/2"
11/2"

EMT
IMC
RSC

1.740
1.883
1.900

3.500
3.500
3.500

LSA315 C 05
LSA300 C 05
LSA300 C 05

LS CS 3.5 16 LSA300 C 05
LS CS 3.5 16 LSA275 C 08
LS CS 3.5 16 LSA275 C 08

WS3.5 32 ➀ LSA315 C 05
WS3.5 22 ➀ LSA300 C 05
WS3.5 22 ➀ LSA300 C 05

2"
2"
2"

EMT
IMC
RSC

2.197
2.360
2.375

4.000
4.000
4.000

LSA315 C 06
LSA300 C 06
LSA300 C 06

LS CS 4 16
LS CS 4 16
LS CS 4 16

LSA315 C 06
LSA300 C 06
LSA300 C 06

WS4 23 ➀
WS4 23 ➀
WS4 23 ➀

LSA315 C 06
LSA300 C 06
LSA300 C 06

21/2"
21/2"

EMT/RSC
IMC

2.875
2.857

4.000
4.000

LSA200 C 09
LSA200 C 09

LS CS 4 16
LS CS 4 16

LSA200 C 09
LSA200 C 09

WS4 23 ➀
WS4 23 ➀

LSA200 C 09
LSA200 C 09

3"
3"

EMT/RSC
IMC

3.500
3.476

5.000
5.000

LSA300 C 08
LSA300 C 08

LS CS 5 16
LS CS 5 16

LSA300 C 08
LSA300 C 08

WS5 25 ➀
WS5 25 ➀

LSA300 C 08
LSA300 C 08

31/2"
31/2"

EMT/RSC
IMC

4.000
3.971

6.000
6.000

LSA325 C 05
LSA325 C 05

LS CS 6 16
LS CS 6 16

LSA325 C 05
LSA325 C 05

WS6 28 ➀
WS6 28 ➀

LSA325 C 05
LSA325 C 05

4"
4"

EMT/RSC
IMC

4.500
4.466

6.000
6.000

LSA300 C 10
LSA300 C 10

LS CS 6 16
LS CS 6 16

LSA300 C 10
LSA300 C 10

WS6 28 ➀
WS6 28 ➀

LSA300 C 10
LSA300 C 10

5"

RSC

5.563

8.000

LSA425 C 06

LS CS 8 16

LSA425 C 06

WS8 32 ➀

LSA425 C 06

6"

RSC

6.625

10.000

LSA475 C 10

LS CS 10 16

LSA475 C 10

WS8 18 ➀

LSA300 C 15

1
1
1

3
3
3

*EMT – Electrical Metallic Tubing; IMC – Intermediate Metal Conduit; RSC – Rigid Steel Conduit
➀Specify length of steel sleeve in inches. Example: S6-28-08 is 8" long. All plastic sleeves come in standard 16" lengths and can be field cut to desired length.
The last two digits of the seal part number indicate the number of links (and the number of bolts) per seal.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

113

4F

Link-Seal® Devices

Fire Rated

4F

Fire Seal for
Conduit passing through
Concrete Walls, Floors or Ceilings
Fire Conduit Seal
Ordering Information:

Sleeve Methods:

Options:

Locate the conduit size and type you are
installing in the columns on the left. Then
locate the seal and sleeve part number
under the installation method you've
selected. No sleeve is needed for cored or
cast hole installation.

Select the appropriate metal sleeve for the
size and type of conduit being installed.
The sleeve should be ordered separately.
Remember to add the wall or floor
thickness to the steel sleeve part number
to insure the sleeve is provided in the
proper length.

Cored or Cast Hole
Method:

Materials:

Note the appropriate hole diameter and
select the seal part number. Example: For
3
/ 4" EMT conduit through a cored hole
–Core a 2" diameter hole and install the
conduit using Link-Seal Part number
LSA200-T-04.

The standard product for fire conduit seals
is made from grey silicone supplied with
steel bolts and nuts with a zinc dichromate
finish. These seals are Factory Mutual
approved for use as a 1-hour fire stop and
can handle temperature extremes of –67°F
to +400°F.

To order the fire seal for a 3-hour rating,
replace the "T" in the seal catalog number
with a "FS". For example, a 1/ 2" seal for
rigid steel conduit for a cored hole is an
LSA200-T-04; ordered with option FS the
catalog number becomes LSA200-FS-04.
A 3-hour fire seal can also be made by
using two Model T’s back-to-back.
The Model FS is basically two Model T's
back-to-back. In Model FS, a tie rod
tightens both seals simultaneously – for
use when only one side of an opening is
accessible.

Fire Conduit Seal - Ordering Information
Conduit
Nominal
Size

Conduit
Type*

EMT
/2"
IMC
/2"
1
RSC
/2"
3
EMT
/4"
3
IMC
/4"
3
RSC
/4"
EMT
1"
IMC
1"
RSC
1"
EMT
11/4"
IMC
11/4"
RSC
11/4"
EMT
11/2"
IMC
11/2"
RSC
11/2"
EMT
2"
IMC
2"
RSC
2"
EMT/RSC
21/2"
IMC
21/2"
EMT/RSC
3"
IMC
3"
EMT/RSC
31/2"
IMC
31/2"
EMT/RSC
4"
IMC
4"
RSC
5"
RSC
6"
➀Specify length of steel sleeve in inches.
1
1

Conduit
Actual O.D.
(inches)

Cast/Cored
Hole Dia.
(inches)

Seal for
Cast/Cored Hole
Cat. #

Steel
Sleeve
Cat. #

Seal for
Steel Sleeve
Cat. #

0.706
0.815
0.840
0.922
1.029
1.050
1.163
1.290
1.315
1.510
1.638
1.660
1.740
1.883
1.900
2.197
2.360
2.375
2.875
2.857
3.500
3.476
4.000
3.971
4.500
4.466
5.563
6.625

2.000
2.000
2.000
2.000
2.500
2.500
3.000
3.000
3.000
3.000
3.000
3.000
3.500
3.500
3.500
4.000
4.000
4.000
4.000
4.000
5.000
5.000
6.000
6.000
6.000
6.000
8.000
10.000

LSA275 T 04
LSA200 T 04
LSA200 T 04
LSA200 T 04
LSA275 T 06
LSA275 T 06
LSA315 T 04
LSA300 T 04
LSA300 T 04
LSA300 T 04
LSA275 T 07
LSA275 T 07
LSA315 T 05
LSA300 T 05
LSA300 T 05
LSA315 T 06
LSA300 T 06
LSA300 T 06
LSA200 T 09
LSA200 T 09
LSA300 T 08
LSA300 T 08
LSA325 T 05
LSA325 T 05
LSA300 T 10
LSA300 T 10
LSA425 T 06
LSA475 T 10

WS2 15 ➀
WS2 21 ➀
WS2 21 ➀
WS2 15 ➀
WS2 15 ➀
WS2.5 20 ➀
WS2.5 20 ➀
WS2.5 10 ➀
WS2.5 20 ➀
WS3.5 22 ➀
WS3.5 22 ➀
WS3.5 22 ➀
WS3.5 32 ➀
WS3.5 22 ➀
WS3.5 22 ➀
WS4 23 ➀
WS4 23 ➀
WS4 23 ➀
WS4 23 ➀
WS4 23 ➀
WS5 25 ➀
WS5 25 ➀
WS6 28 ➀
WS6 28 ➀
WS6 28 ➀
WS6 28 ➀
WS8 32 ➀
WS8 18 ➀

LSA275 T 04
LSA200 T 04
LSA200 T 04
LSA200 T 04
LSA200 T 04
LSA275 T 06
LSA275 T 06
LSA275 T 06
LSA200 T 05
LSA315 T 05
LSA315 T 05
LSA300 T 05
LSA300 T 05
LSA300 T 05
LSA275 T 08
LSA315 T 06
LSA300 T 06
LSA300 T 06
LSA200 T 09
LSA200 T 09
LSA300 T 08
LSA300 T 08
LSA325 T 05
LSA325 T 05
LSA300 T 10
LSA300 T 10
LSA425 T 06
LSA300 T 15

Example: WS6-28-08 is 8" long.
*EMT – Electrical Metallic Tubing; IMC – Intermediate Metal Conduit; RSC – Rigid Steel Conduit
The last two digits of the seal part number indicate the number of links (and the number of bolts) per seal.

114

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Link-Seal® Devices

4F

Dimensions

4F

Dimensions
In Inches:

Technical Information
Rubber Sealing Element
Avg. Length After
Free
Tightening
Length
(inches)
(inches)

Link-Seal
Cat. #

Actual
Thickness
(inches)

LSA200 C

.478

13/4

LSA275 C

.607

LSA300 C
LSA315 C

Pressure Plate

Bolt

A
(inches)

R
(inches)

T
(inches)

13/8

11/6

21/4

5

13/4

13/8

7

/8

17/8

5

.687

21/2

2

11/2

21/2

7

.807

21/2

2

17/16

21/2

7

LSA325 C

.875

3

23/8

31/8

2

1

LSA425 C

1.062

31/2

23/4

31/2

3

3

LSA475 C

1.562

31/2

23/4

31/2

31/2

1

www.crouse-hinds.com

US: 1-866-764-5454

Hex
Across
Flats

H
(inches)

Thread
Size
(inches)

L

/16

M5
slotted hex

.180

M5

21/2

/16

M5
slotted hex

.180

M5

21/2

/16

1

/32

5/16–5/18

31/2

/16

1

/32

5/16–5/18

31/2

/2

1

/32

5/16–5/18

4

/4

9

/4

3/8–3/16

5

/2

9

/4

3/8–3/16

41/2

CAN: 1-800-265-0502

/2

7

/2

7

/2

7

/16

1

/16

1

Copyright© 2013 Eaton’s Crouse-Hinds Business

115

4F

4F

116

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Elbows, Couplings, Hubs, Grounding
Devices, Plugs, Reducers, Service
Entrance and Unions
Hazardous and Non-hazardous
Page No.

Application/Selection

see page 118

EL Series
FE / FT Series

see page 121
see page 122

EC Series
XD Series
XJG Series
XJG-EMT Series
XJGD Series

see pages 127–128
see page 129
see page 130
see page 131
see page 132

Grounding Devices, Straps, Clamps
see page 134

Hubs
see page 133

Pipe Plugs
PLG Series
NOR Series

Service Entrance Fittings
F Series

see page 135

Unions
Non-Expansion

Flexible & Expansion Joint Couplings

HUB Series

Page No.

Heads

Elbows

GC Series

Description

UNA Series
UNF Series
UNL Series
UNY Series

page
page
page
page

121
120
120
120

see
see
see
see

page
page
page
page

123
123
123
123

Expansion
UNF Series
UNY Series
UNFL Series
UNYL Series

Nipples
NOR Series

see page 124
see page 126

see
see
see
see

see page 126

Conduit Liners
LNR Series

see page 136

Reducers and Adapters
AMN / ANM Series
RE Series
REA Series
REC Series
NOR Series

see
see
see
see
see

www.crouse-hinds.com

page
page
page
page
page

125
124
124
124
126

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

117

5F

Description

5F

Elbows, Couplings, Hubs, Grounding
Devices, Plugs, Reducers, Service
Entrance and Unions

5F

5F

Application and Selection
Applications:

Series

Service entrance heads, elbows, unions,
couplings, grounding receptacle and stud
and grounding straps with clamps are the
miscellaneous fittings needed to complete
an electrical conduit system from the
overhead service entrance to machinery,
lighting fixtures and/or final electrical
outlets. These fittings are installed in
conduit systems within non-hazardous
areas to:
• Plug
• Connect
• Reduce
• Terminate
• Change direction
• Ground

Page

Series

Page

Series

Page

F

see page 135

UNL

see page 120

XD

see page 129

GCT

see page 134

UNF

see page 120

XJG

see page 130

GC

see page 134

EL / FE

RE

see page 124

REA / AMN

see page 124

REC

see page 124

HUB

see page 133

XJG-EMT

see page 131

Use in Hazardous Areas:
• Most of the items shown above are also
suitable for hazardous areas (see
specific listings for compliance
information).

see pages
121–122

Considerations for
Selection:
Service Heads:
• Size required – determine from size and
number of conductors in service and
conduit or mast size.
• Type required – (threaded, slip fit,
clamp) – determine from conduit used
with service head.
Elbows, Unions, Reducers, Couplings and
Grounding Receptacles/Connectors:
• Size required – determine from conduit
size.
• Type required – determine from
intended function in system (i.e. male
and female thread for connecting
conduit to outlet box etc.)
• Material and finish required – determine
from environmental conditions (corrosive
fumes, buried in concrete, etc.)

GCR

see page 134

UNYL

see page 123

LNR

PLG

see page 136

see
page 124

Options:
Description
Corro-free™ epoxy powder coat

Suffix
S752
see pages
127–128

EC

XJGD

118

www.crouse-hinds.com

US: 1-866-764-5454

see page 132

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

5F

Elbows, Couplings, Hubs, Grounding
Devices, Plugs, Reducers, Service
Entrance and Unions

5F

Quick Selector Chart
Standard
Materials

Series

Description

Size Range

Conduit Type

XD

Expansion/deflection
coupling

1" to 6"

Threaded rigid

Feraloy® iron alloy hubs,
neoprene outer jacket, tinned
copper grounding strap

F

Threaded service entrance
head

1

/2" to 4" conduit

Threaded rigid

Copper-free aluminum

F

Clamp type service entrance
head

3

/4" to 2" conduit

Threadless rigid or EMT

Copper-free aluminum

GCT

Ground connector and stud

.312" to .406"

Used to provide "quick
connect" static electricity
grounding connections with
portable cable

Bronze connector body;
aluminum cable clamp; brass
stud

GC100

Grounding strap

50' coil

Used for bonding and
grounding

Flexible copper, tinned

GCR

Grounding receptacle

3

/4" threaded grounding
rod

Used to provide static
electricity grounding
connection

Bronze body, cap and chain;
brass grounding stud

GC102

Grounding clamp

Adjustable

Used as clamp for GC100

Brass

HUB

Conduit hub

1

/2" to 4"

Threaded rigid

Steel or Feraloy iron alloy

UNL

Union, 90° angle; for
connecting conduit to cast
boxes

1

/2" - 1/2" to 3/4" - 3/4"

Threaded rigid

Feraloy iron alloy

UNY

Union, male; for connecting
conduit to cast boxes

1

/2" to 6" / 20mm to 50mm

Threaded rigid

Steel or Feraloy iron alloy

UNF

Union, female; for connecting
conduit to conduit

1

/2" to 6" / 20mm to 50mm

Threaded rigid

Steel or Feraloy iron alloy

UNA Male

Union, 90° to 180°
adjustable; for connecting
conduit to boxes for conduit
support

1

/2" to 1"

Threaded rigid

Feraloy iron alloy

EL-45°

45° elbow, female

12" to 4"

Threaded rigid

Feraloy iron alloy

EL-90°

90° elbow, male; 90° elbow,
female; 90° elbow, male and
female

/2" to 11/4" male; 1/2" to 21/2"
female; 1/2" to 11/4" male
and female

Threaded rigid

Feraloy iron alloy

FE

90º elbow, metric

RE

Reducer, threaded

REA / AMN

Adapter fitting

1

1

20mm to 25mm

Threaded rigid

Cooper-free aluminium

1

/2" - 1/8" to 6" - 5" / 20mm
to 50mm

Threaded rigid

Steel or Feraloy iron alloy

/2" male to 3/4" female; 3/4"
male to 1" female; 1" male to
11/4" female; 16mm to 63mm

Threaded rigid

Steel or Brass

/4" - 1/2" to 5" - 4"

Threaded rigid

Feraloy iron alloy

/2" to 4" / 20mm to 63mm

Threaded rigid

Steel or Feraloy iron alloy or
Brass

/2" to 4"

See catalog page 7F for
details

/2" to 4"

Threaded rigid & IMC

Polypropylene

/2" to 6"

Threaded rigid or IMC

Feraloy iron alloy

REC

Reducer coupling

3

PLG

Pipe plug, recessed head or
square head

1

EC

Flexible coupling

1

LNR

Conduit liner

1

XJG

Expansion fitting

1

XJG-EMT

Expansion fitting

1

/2" to 4"

EMT

Feraloy iron alloy

XJGD

Expansion-deflection

1" to 4"

Threaded rigid

Feraloy iron alloy

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

119

5F

5F

Unions and Elbows

Applications:

Standard Materials:

UNY and UNF unions are installed in
threaded thickwall conduit systems:
• UNY – to connect conduit to a conduit
fitting, junction box or device enclosure
• UNF – to connect conduit to conduit, or
to provide a means for future
modification of the conduit system
UNA unions are used in conduit and fitting
installations when entrance angle is
between 90° and 180°.
EL elbows are installed in conduit run or in
box or fitting hub:
• To change direction in threaded rigid
conduit run by 90°, or when terminating
at a box or fitting

• UNY, UNF unions – 1/2" to 1" – steel
• UNY, UNF unions – 11/4" to 6" – Feraloy®
iron alloy
• UNL, UNA unions – Feraloy iron alloy
• EL elbows – Feraloy iron alloy or ductile
iron

Features:

Description
Copper-free aluminum
Not available on UNA or 5" and
6" UNY/UNF

UNY, UNF and UNL unions have:
• Compact design which permits
assembly with a minimum of clearance
to other adjacent conduit and/or
equipment
• Strong and durable construction
UNA unions:
• Have a single clamping nut on angle,
making it both a union and a connector
• Permit conduit joints at angles between
90° and 180°
EL elbows have a smooth interior and are
both strong and compact.

• Steel – electrogalvanized with chromate
treatment
• Feraloy iron alloy, malleable iron –
electrogalvanized and aluminum acrylic
paint

Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
UNF/UNY406, -506,
-606, -706, -806,
-905, -1005

DIA

1

/2" – 4"

5" – 6"

5" – 6"

Cat. #

Size

Cat. #

/2
1
/2 female
to 3/4 male
3
/4
1
11/4
11/4
11/2
11/2
2
2
21/2
21/2
3
3
31/2
4
5
6

UNY105

1

/2

UNF105

UNY215

3

/4 to 1/2

UNF215

UNY205
UNY305
UNY405
UNY406
UNY505
UNY506
UNY605
UNY606
UNY705
UNY706
UNY805
UNY806
UNY905
UNY1005
UNY012
UNY014

/4
1
11/4
11/4
11/2
11/2
2
2
21/2
21/2
3
3
31/2
4
5
6

UNF205
UNF305
UNF405
UNF406
UNF505
UNF506
UNF605
UNF606
UNF705
UNF706
UNF805
UNF806
UNF905
UNF1005
UNF012
UNF014

LENGTH

90° Angle
Cat. #

/2
3
/4
1
/2
3
/4

UNL105
UNL125
UNL215
UNL205

1

to 1/2
female to 1/2 male
female to 3/4 male
to 3/4

Dimensions
In Inches:

3

UNY

Size

Size
1
/2
3
/4 – 1/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4
5
6

Max.
Length Dia.
25/8
11/2
211/16
113/16
211/16
113/16
3
17/8
311/16
23/4
41/4
31/16
41/4
313/16
57/16
45/16
53/4
51/ 16
61/2
511/16
65/8
63/ 16
61/8
83/ 16
61/8
95/ 16

UNF
Length
113/16
13/4
13/4
2
21/4
25/8
29/16
33/16
37/16
41/8
41/8
313/16
313/16

Max.
Dia.
11/2
113/16
113/16
17/8
23/4
31/16
313/16
45/16
51/16
511/16
63/16
83/16
95/16

215
27/8
113/16
21/4
15/8

205
27/8
113/16
21/4
15/8

UNL
Dim.
a
b
c
d

• UL Standard: 1203
• CSA Standard: C22.2 No. 30
†See compliances for classification of each product.

US: 1-866-764-5454

/2" – 4"

Size
1

Class I, Division 1 & 2, Group D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
UNA

www.crouse-hinds.com

1

Suffix
SA

UNY

Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EL, UNF, UNL, UNY - all sizes

120

UNF
Female

Options:

• NEC/CEC:
Class I, Division 1 & 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EL 1/2", 3/4", 1"
UNF/UNY 105, -215, -205, -305
UNL 105, -125, -215, -205

UNY
Male

Standard Finishes:

UNL

Certifications and
Compliances:

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups A, B, C, D†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

105
211/16
117/32
21/16
17/16

125
211/16
113/16
21/16
17/16

Cl. I, Div. 1 & 2, Groups C, D†
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Unions and Elbows

UNA

Explosionproof
Dust-Ignitionproof

5F

5F

EL

Male (with removable nipple)
90° Female

Male
Size

Cat. #

/2
/4
1

UNA16
UNA26
UNA36

1
3

90° Male

90° Male and female

45° Female

90° Male

90° Female

Size

Cat. #

Size

Cat. #

/2
3
/4
1

EL195
EL295
EL395

/2
3
/4
1
11/4
11/2
2
21/2

EL19*
EL29*
EL39*
EL49*
EL59*
EL69*
EL79

1

1

45° Female
Size

Cat. #

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

EL1
EL2
EL3
EL4
EL5
EL6
EL7
EL8
EL9
EL10

1

Dimensions

UNA

In Inches:

Male
Size
1
/2
3
/4
1

90° Male

90° Female

45° Female

90° Male and
female

90° Male and Female
Size

Cat. #

/2
3
/4
1
11/4

EL196*
EL296*
EL396*
EL496

1

*Available in copper free aluminum – add suffix SA to
catalog number.

EL
Length

Width

45/16
413/16
511/16

25/8
27/8
31/2

45°
90°
90°
Female Male Female
Size
/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4
1

a
13/16
13/8
121/32
13/4
115/16
21/4
23/4
31/6
37/16
35/8

a
17/16
15/8
17/8

a
117/32
13/4
2
21/4
4
5
67/16

90°
Male &
Female
a
117/32
15/8
17/8
21/8

EL
†See compliances for classification of each product.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

121

Condulet® Elbows and Tees
For IEC Applications

5F

Zone 1
Zone 2

Zone 21
Zone 22

5F

FE and FT Series
Applications:
FE and FT conduit fittings are installed in
hazardous areas to:
• Act as draw-in outlets especially for
cables that are stiff due to large size or
type of insulation
• Make 90º bends in conduit systems,
allowing for a straight pull in either
direction
• Provide access to wiring for
maintenance and future system changes

Features:
• Maximum volume for bends within a
compact overall size
• Large openings to facilitate cable pulling

Ordering Information:
Inspection Elbows and Tees Selection

Certifications and
Compliances:

Cat. #

Type

Entry Size (metric)

• Ex d, DIP A21, IP67

FE1
FE2
FT1
FT2

Elbow
Elbow
Tee
Tee

M20
M25
M20
M25

Degree of Protection

Dimensions (mm)

Type of Protection

• IP67
Gas Group
• IIB
Approvals
• Ex1108U

Standard Materials:
• Body – Copper-free aluminum
• Cover – Brass

Standard Finishes:
• Natural

Options:
Description
NPT & BSP thread sizes

122

Suffix
Consult Factory

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

(F)-M20
(F)-M25
(F)-M20
(F)-M25

(F)
(F)
(F)
(F)

UNF/UNY Expansion Unions

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Explosionproof
Dust-Ignitionproof

5F

5F

Applications:
UNF/UNY expansion unions are designed
to be used in all threaded rigid metal†
conduit systems indoors and outdoors, in
hazardous locations to:
UNYL

UNFL

UNYL with sleeve extended

UNFL with sleeve extended

• Connect conduit to conduit
• Connect conduit to a junction box or
device enclosure
• Compensate for conduit cut too short
• Allow for expansion and contraction of
conduit
• Connect stub-ups to threaded conduit

UNF

UNY

• Replace sections of conduit runs

Female – Short

Male – Short

Features:

Conduit Size

Cat. #

Conduit Size

Cat. #

• Compact design

/2
3
/4
1

UNY17
UNY27
UNY37

/2
3
/4
1

UNF17
UNF27
UNF37

1

• Internal beryllium copper grounding
spring to insure positive grounding
continuity.
• Knurled surface on body and sleeve
allows secure gripping with wrench.

1

UNYL

UNFL

Male – Long

Female – Long

Conduit Size

Cat. #

Conduit Size

Cat. #

• Steel construction for maximum
strength.

/2
3
/4
1

UNYL17
UNYL27
UNYL37

/2
3
/4
1

UNFL17
UNFL27
UNFL37

• Available in two styles – short length
where space is limited, long length when
extra expansion is required.

Dimensions

1

1

In Inches:

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Standard Materials:
• Body and sleeve – steel
• Grounding spring – beryllium copper

Standard Finishes:
• Steel – electrogalvanized with chromate
finish
• Beryllium copper – natural

Size

Dimension
a*

b

c‡

d

UNY
1
/2
3
/4
1

35/16
33/8
313/16

13/16
17/16
111/16

1
1

/2
/2
5
/8

21/16
21/8
21/4

UNYL
1
/2
3
/4
1

45/16
41/2
53/16

13/16
17/16
111/16

1
11/16
15/16

29/16
211/16
215/16

Size

Dimension
a*

b

c‡

d

UNF
1
/2
3
/4
1

33/8
37/16
313/16

13/16
17/16
111/16

1

/2
/2
5
/8

27/8
215/16
33/16

UNFL
1
/2
3
/4
1

43/8
49/16
51/8

13/16
17/16
111/16

1
11/16
15/16

33/8
31/2
313/16

1

*Overall length at maximum expansion
‡Maximum expansion
†Suitable with intermediate Metal Conduit in non-hazardous locations

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

123

5F

5F

Applications:

RE

• RE and REC reducers are used in
threaded heavy wall conduit systems.
• RE reduces conduit hubs to a smaller size.
• REA adapters enlarge drilled and tapped
openings by 1 NPT size.
• REC connects two different sizes of
conduit together or is used to replace a
coupling and reducer in an installation.
• PLG plugs are used for closing threaded
conduit hubs.

Features:
RE reducers have:
• Integral bushing which prevents damage
to wires
• Full, clean cut tapered threads
REC reducers have:
• Integral bushings in both ends which
prevents damage to wires
• Funnel shaped interior to guide the wires
from large to small conduit, making it
easy to pull wire
REA adapters have:
• Smooth integral bushing to protect wire
insulation
• Knurled body for easy wrenching
PLG plugs:
• Have clean tapered threads
• Are available in two styles, flush
(recessed), or square head type

Certifications and
Compliances:
• NEC/CEC:
Class I, Division 1 & 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
(see listings for specific Cat. Nos. suitable
for Groups A or B)
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups A†, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Reducers, Couplings
and Plugs

REA

Size

Cat. #

/2 – 1/8
1
/2 – 1/4
1
/2 – 3/8
3
/4 – 1/2
1 – 1/2
1 – 3/4
11/4 – 1/2
11/4 – 3/4
11/4 – 1
11/2 – 1/2
11/2 – 3/4
11/2 – 1
11/2 – 11/4
2 – 1/2
2 – 3/4
2–1
2 – 11/4
2 – 11/2
21/2 – 1
21/2 – 11/4
21/2 – 11/2
21/2 – 2
3–1
3 – 11/4
3 – 11/2
3–2
3 – 21/2
31/2 – 2
31/2 – 21/2
31/2 – 3
4–2
4 – 21/2
4–3
4 – 31/2
5–4
6–5

RE1108*
RE1208*
RE1308
RE21†
RE31†
RE32†
RE41†
RE42†
RE43†
RE51†
RE52†
RE53†
RE54†
RE61†
RE62†
RE63†
RE64†
RE65†
RE73†
RE74†
RE75†
RE76†
RE83†
RE84†
RE85†
RE86†
RE87†
RE96†
RE97†
RE98†
RE106†
RE107†
RE108†
RE109†
RE01210
RE01412

1

REC

Male
Hub
Size

Female
Hub
Size

Cat. #

/2
3
/4
1

/4
1
11/4

REA12†
REA23†
REA34†

1

3

PLG

Recessed

Square Head

Recessed
Size

Cat. #

/4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

PLG28†
PLG1†
PLG2†
PLG3†
PLG4
PLG5
PLG6
PLG7
PLG8
PLG9
PLG10

1

Square Head

Standard Materials:

Size

Cat. #

• RE reducers – RE1108 through RE54 in
steel; all others in Feraloy® iron alloy
• REA adapters – steel
• REC reducers – REC21 and REC32 in
steel; all others in Feraloy iron alloy
• PLG plugs – Recessed: PLG28-PLG3:
steel, PLG4-PLG10: grey iron alloy;
Square Head: PLG15-PLG55: steel,
PLG65-PLG105: grey iron alloy

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

PLG15†
PLG25†
PLG35†
PLG45
PLG55
PLG65
PLG75
PLG85
PLG95
PLG105

Standard Finishes:
• Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
• Steel – electrogalvanized with chromate
treatment

Options:
Description
Copper-free aluminum
124

www.crouse-hinds.com

Suffix
SA
US: 1-866-764-5454

1

Large
Hub
Size

Small
Hub
Size

Cat. #

/4
1
1
11/4
11/4
11/2
11/2
11/2
2
2
2
2
21/2
3
31/2
4
5

/2
1
/2
3
/4
3
/4
1
3
/4
1
11/4
3
/4
1
11/4
11/2
11/2
2
21/2
3
4

REC21†
REC31†
REC32
REC42
REC43
REC52
REC53
REC54
REC602
REC603
REC604
REC605
REC75
REC86
REC97*
REC108*
REC01210*

3

1

CAN: 1-800-265-0502

*Not available in aluminum.
†Suitable for use in Class I, Groups A and B areas.

Copyright© 2013 Eaton’s Crouse-Hinds Business

Zone 1
Zone 2

AMN / ANM Adapters
For IEC Applications

Zone 21
Zone 22

5F

5F

Application:
Adapters are used to change the thread form and/or size in a wide
range of BSP, NPT, and metric cable and conduit entries.

Certifications and Compliances:
Type of Protection
• Ex d, DIP A21, IP67
Degree of Protection
• IP66/67
Gas Group
• IIC
Approvals

Notes:

• Ex1108U

1. Adapters have different size thread at each end
2. Adapters may step up the same type of thread
3. Downwards adapters are Type A; upward or same size adapters
are Type B
4. For downward adapters of same thread type, see Reducers
Catalog Page
5. For same size and type of thread, see Unions Catalog Page

Standard Materials:
• Brass, nickel plated

Standard Finish:
• Natural

Options:
Stainless Steel - Replace NP with SS

Size Ranges:
• Standard sizes listed in table below; other sizes may be available;
please consult factory

Ordering Information:

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

125

5F

5F

Reducers, Adapters, Plugs and
Nipples for IEC Applications

IP67

Ex II 2 G EEx e II
Ex II 2 G EEx d IIC
Ex II 2 D

Applications:
• Reducers are used in threaded heavy wall conduit systems to
reduce conduit hubs to a smaller size or to connect two different
sizes of conduit together
• Adapters enlarge drilled and tapped openings by 1 NPT size
• Plugs are used for closing unused threaded conduit hubs

Features:
Reducers:
• Integral bushing which prevents damage to wires
• Full, clean cut tapered threads
• Funnel shaped interior to guide the wires from large to small
conduit, making it easy to pull wire
Adapters:
• Smooth integral bushing to protect wire insulation
• Knurled body for easy wrenching
Plugs:
• Full, clean cut tapered threads

Certifications and Compliances:
• Plugs:
Ex II 2 G EEx e II
Ex II 2 G EEx d IIC
EC-Type examination certificate LOM 02 ATEX 3035U
IP67
• Reducers and Adapters:
Ex II 2 G EEx e II
Ex II 2 G EEx d IIC
Ex II 2 D
EC-Type examination certificate LOM 03 ATEX 3019U
IP67
• Nipples:
Ex II 2 G EEx d IIC
EC-Type examination certificate LOM 03 ATEX 3019U
IP67

Standard Materials:

Ordering Information - Reducers
Male Thread

Female Thread

Cat. #

/4" ISO 7/1
1" ISO 7/1
1
/2" ISO 7/1
3
/4" ISO 7/1

/2" ISO 7/1
3
/4" ISO 7/1
3
/4" ISO 7/1
1" ISO 7/1

NOR
NOR
NOR
NOR

3

1

000
000
000
000

002
002
002
002

190
190
190
190

112
188
675
740

190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190

010
015
014
009
008
013
012
011
002
001
017
016
000
020
007
005
006
004
018
019
003

Ordering Information - Adapters
Male Thread

Female Thread

Cat. #

M20 x 1.5
PG13
PG16
M20 x 1.5
M25 x 1.5
PG13
PG16
PG21
1
/2" ISO 7/1
3
/4" ISO 7/1
PG13
PG16
3
/4" ISO 7/1
PG16
1
/2" ISO 7/1
3
/4" ISO 7/1
1
/2" ISO 7/1
3
/4" ISO 7/1
M20 x 1.5
M25 x 1.5
3
/4" ISO 7/1

1

/2" ISO 7/1
1
/2" ISO 7/1
1
/2" ISO 7/1
3
/4" ISO 7/1
3
/4" ISO 7/1
3
/4" ISO 7/1
3
/4" ISO 7/1
3
/4" ISO 7/1
M20 x 1.5
M20 x 1.5
M20 x 1.5
M20 x 1.5A
M25 x 1.5
M25 x 1.5
PG13
PG13
PG16
PG16
PG16
PG16
PG21

NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR

000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000

112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112
112

• Reducers, Adapters, Plugs and Nipples - Zinc Plated Steel

Ordering Information - Plugs

Ordering Information - Nipples

Thread Size

Cat. #

Thread Size

Type

Cat. #

/2" ISO 7/1
3
/4" ISO 7/1
1" ISO 7/1
1" NPT
M20 x 1.5
M25 x 1.5
M32 x 1.5
M50 x 1.5
M60 x 1.5

NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR

/2" ISO 7/1
3
/4" ISO 7/1
1" ISO 7/1
1
/2" ISO 7/1
3
/4" ISO 7/1
1" ISO 7/1

EMM 1
EMM 2
EMM 3
EMF 1
EMF 2
EMF 3

NOR
NOR
NOR
NOR
NOR
NOR

1

000
000
000
000
000
000
000
000
000

002
002
002
002
002
002
002
002
002

140
140
140
140
140
140
140
140
140

117
125
133
365
655
656
657
658
659

1

Type PLG

126

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

000
000
000
000
000
000

002
002
002
002
002
002

130
130
130
130
130
130

118
126
134
217
225
233

Cl. I, Groups A, B, C, D
Cl. II, Groups E, F, G
Cl. III

Couplings
"–2" Brass Construction
2-1/2–4" Stainless Steel construction only
1

/2

Explosionproof
Dust-Ignitionproof
Wet Locations

5F

5F

Applications:
EC couplings are used:
• In hazardous areas where a flexible
member is required in a conduit system
to accomplish difficult bends, or to allow
for movement or vibration of connected
equipment or units

Features:
• Rugged design to withstand explosive
pressure (Class I)
• Mechanical abuse
• Liquid-tight for wet locations
• For use where lack of space makes use
of rigid conduit difficult
• Wire duct liner in sizes 1/2" to 2"
insulates against grounds and burnthrough from short circuit
• No bonding jumpers required, metallic
braid provides continuous electrical path
• ECGJH combination has two threaded
male end fittings
• ECLK combination has one female union
and one male threaded end fitting

Certifications and
Compliances:
• NEC:
1
/2" and 3/4" (Brass and S516) – Class I,
Division 1, Groups A, B, C, D
1" to 2" (Brass and S516) – Class I,
Division 1, Groups C, D
All sizes also for use in Class II, Division 1,
Groups E, F, G and Class III
• UL Standard: 1203
• ATEX and IECEx - ECGJH S516 Only:
1
/2" and 3/4" (4" to 36" flexible length
only) – Ex d IIC, IP66
1", 11/4", 11/2", 2" (4" to 36" flexible
length only) – Ex d IIB, IP66

ECGJH (Male connections both ends)
Flexible
Length
(In.)
4
4
6
6
6
8
8
8
10
10
10
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
18
18

Flexible
Length
Size Cat. #
(In.)
1
/2
ECGJH14
18
3
/4
ECGJH24
18
1
/2
ECGJH16
18
3
/4
ECGJH26
18
1
ECGJH36
18
1
/2
ECGJH18
18
3
/4
ECGJH28
18
1
ECGJH38
21
1
/2
ECGJH110 21
3
/4
ECGJH210 21
1
ECGJH310 21
1
/2
ECGJH112 21
3
/4
ECGJH212 21
1
ECGJH312 21
1
1 /4 ECGJH412 21
11/2 ECGJH512 21
2
ECGJH612 24
21/2 ECGJH712 24
3
ECGJH812 24
4
ECGJH1012 24
1
/2
ECGJH115 24
3
/4
ECGJH215 24
1
ECGJH315 24
1
1 /4 ECGJH415 24
11/2 ECGJH515 24
2
ECGJH615 27
21/2 ECGJH715 27
3
ECGJH815 27
4
ECGJH1015 27
1
/2
ECGJH118 27
3
/4
ECGJH218 27

Flexible
Length
Size Cat. #
(In.)
1
ECGJH318 27
11/4 ECGJH418 27
11/2 ECGJH518 27
2
ECGJH618 30
21/2 ECGJH718 30
3
ECGJH818 30
4
ECGJH1018 30
1
/2
ECGJH121 30
3
/4
ECGJH221 30
1
ECGJH321 30
1
1 /4 ECGJH421 30
11/2 ECGJH521 30
2
ECGJH621 33
21/2 ECGJH721 33
3
ECGJH821 33
4
ECGJH1021 33
1
/2
ECGJH124 33
3
/4
ECGJH224 33
1
ECGJH324 33
1
1 /4 ECGJH424 33
11/2 ECGJH524 33
2
ECGJH624 36
21/2 ECGJH724 36
3
ECGJH824 36
4
ECGJH1024 36
1
/2
ECGJH127 36
3
/4
ECGJH227 36
1
ECGJH327 36
1
1 /4 ECGJH427 36
11/2 ECGJH527 36
2
ECGJH627

Size Cat. #
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4

ECGJH727
ECGJH827
ECGJH1027
ECGJH130
ECGJH230
ECGJH330
ECGJH430
ECGJH530
ECGJH630
ECGJH730
ECGJH830
ECGJH1030
ECGJH133
ECGJH233
ECGJH333
ECGJH433
ECGJH533
ECGJH633
ECGJH733
ECGJH833
ECGJH1033
ECGJH136
ECGJH236
ECGJH336
ECGJH436
ECGJH536
ECGJH636
ECGJH736
ECGJH836
ECGJH1036

Dimensions
In Inches:

Standard Materials and Finishes:
• End fittings:
1
/2" to 2" – forged brass; natural
21/2" to 4" – stainless steel; natural
• Female unions:
1
/2" to 1" – steel; electrogalvanized with chromate treatment
11/4" to 4" – Feraloy® iron alloy; electrogalvanized with aluminum
acrylic paint
• 1/2" to 2" have bronze braid covering and flexible brass inner core;
packing is woven cotton braid impregnated with asphalt
• 21/2" to 4" have a Type 304 stainless steel braid

ECGJH

Options:
Description

Suffix

All stainless steel (available for ECGJH only)

S516

For severely corrosive locations, a flexible PVC protective
coating will be supplied

S758

Special coupling lengths available up to 144 inches. To order,
change last two digits in any standard catalog number to the
two or three digit length desired in whole inches i.e. To order
a 3/ 4" trade size 110 inches long, use catalog number
ECGJH2110.

www.crouse-hinds.com

US: 1-866-764-5454

ECLK

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

127

Couplings

5F

"–2" Brass Construction
2-1/2–4" Stainless Steel construction only
1

5F

/2

Cl. I, Groups A, B, C, D
Cl. II, Groups E, F, G
Cl. III

ECLK (ECGJH provide with UNF Female union – male
connection 1 end, female connection 1 end)
Flexible
Length (In.) Size
/2
3
/4
1
/2
3
/4
1
1
/2
3
/4
1
1
/2
3
/4
1
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1

4
4
6
6
6
8
8
8
10
10
10
12
12
12
12
12
12
12
12
12
15
15
15
15
15
15
15
15
15
18
18

Cat. #

Flexible
Length (In.) Size

Cat. #

ECLK14
ECLK24
ECLK16
ECLK26
ECLK36
ECLK18
ECLK28
ECLK38
ECLK110
ECLK210
ECLK310
ECLK112
ECLK212
ECLK312
ECLK412
ECLK512
ECLK612
ECLK712
ECLK812
ECLK1012
ECLK115
ECLK215
ECLK315
ECLK415
ECLK515
ECLK615
ECLK715
ECLK815
ECLK1015
ECLK118
ECLK218

18
18
18
18
18
18
18
21
21
21
21
21
21
21
21
21
24
24
24
24
24
24
24
24
24
27
27
27
27
27
27

ECLK318
ECLK418
ECLK518
ECLK618
ECLK718
ECLK818
ECLK1018
ECLK121
ECLK221
ECLK321
ECLK421
ECLK521
ECLK621
ECLK721
ECLK821
ECLK1021
ECLK124
ECLK224
ECLK324
ECLK424
ECLK524
ECLK624
ECLK724
ECLK824
ECLK1024
ECLK127
ECLK227
ECLK327
ECLK427
ECLK527
ECLK627

1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2

Flexible
Length (In.)

Size

Cat. #

27
27
27
30
30
30
30
30
30
30
30
30
33
33
33
33
33
33
33
33
33
36
36
36
36
36
36
36
36
36

21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4

ECLK727
ECLK827
ECLK1027
ECLK130
ECLK230
ECLK330
ECLK430
ECLK530
ECLK630
ECLK730
ECLK830
ECLK1030
ECLK133
ECLK233
ECLK333
ECLK433
ECLK533
ECLK633
ECLK733
ECLK833
ECLK1033
ECLK136
ECLK236
ECLK336
ECLK436
ECLK536
ECLK636
ECLK736
ECLK836
ECLK1036

ECGJH and ECLK
Size
1
/2
3
/4
1
11/4
11/2
2
21/2
3
4

a

b

c

d

e

17/8
21/16
21/2
27/8
35/16
31/4
3
31/8
45/8

11/2
17/8
21/8
215/16
31/2
41/4
47/16
49/16
415/16

11/8
13/16
11/2
17/8
17/8
2
15/8
13/4
31/4

3
31/4
35/8
43/16
53/16
51/16
51/16
53/8
71/2

19/16
113/16
17/8
23/4
31/16
313/16
45/16
51/16
63/16

Minimum Recommended Radius of Bend
Size
1
/2
3
/4
1
11/4
11/2

128

Radius

Size

Radius

10
12
14
14
16

2
21/2
3
4

16
16
18
30

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Explosionproof
Dust-Ignitionproof
Wet Locations

Watertight
Corrosion-Resistant

5F

1. Axial expansion/contraction.

2. Angular misalignment.

XD Expansion/Deflection Coupling

Applications:

5F

XD

XD couplings can be installed indoors, outdoors, buried
underground, or embedded in concrete in non-hazardous areas.
XD's are used with standard rigid conduit or PVC rigid conduit. (PVC
requires rigid metal conduit nipples and rigid metal-to-PVC conduit
adapters.) XD's provide a flexible and watertight connection for
protection of conduit wiring systems from damage due to movement.
Typical applications include:
• Underground conduit feeder runs
• Runs between sections of concrete subject to relative movement
• Runs between fixed structures
• Conduit entrances in high-rise buildings

Ordering
Information

• Bridges
• Marinas, docks, piers

Features:
• XD couplings accommodate the following movements without
collapsing or fracturing the conduit, and damaging the wires it
contains:
1. Axial expansion or contraction up to 3/4"

Hub
Hub Size Cat. # Size

Cat. #

1
11/4
11/2
2
21/2

XD8
XD9
XD010
XD012
XD014

XD3
XD4
XD5
XD6
XD7

3
31/2
4
5
6

3. Parallel misalignment.

2. Angular misalignment of the axes of the coupled conduit runs
in any direction to 30°
3. Parallel misalignment of the axes of coupled conduit runs in
any direction to 3/4"
• Inner sleeve maintains constant I.D. in any position and provides a
smooth insulated wireway for protection of wire insulation
• Watertight flexible neoprene outer jacket is corrosion resistant and
protects the grounding strap and the attachment points of the
hubs
• Tinned copper flexible braid grounding straps assure grounding
continuity
• Stainless steel jacket clamps for strength and corrosion resistance
• Standard tapered electrical threads fit standard rigid conduit
• Integral hub bushing protects insulation of conductors

Certifications and Compliances:
• UL Standard: 514B

Standard Materials:

Dimensions

• Hubs – Feraloy® iron alloy

In Inches:

• Outer jacket – molded neoprene

Hub
Size
1
1- 1/4
11/2
2
21/2
3
31/2
4
5
6

• Jacket clamps – stainless steel
• Inner sleeve – molded plastic
• Grounding straps – tinned copper flexible braid

Standard Finishes:
• Feraloy – electrogalvanized
• Neoprene – natural (black)
• Molded plastic – natural (brown)

a

b

7
73/8
71/4
71/4
71/2
75/8
73/4
77/8
73/4
83/8

315/16
41/4
41/2
415/16
55/16
515/16
61/2
615/16
8
9

Options:
Description
Hot dipped galvanized

Suffix
HDG

Size Ranges:
• 1" to 6" (Smaller sizes can be obtained by using reducing
bushings)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

129

5F

5F

Wet Locations

XJG Conduit Expansion Joints
With Internal Grounding
For Rigid Metal Conduit and IMC

Applications:
XJG expansion couplings are used with
rigid metal conduit and IMC:
• Without the need for an external bonding
jumper and clamps (up to 4")
• To couple together two (2) sections of
conduit subject to longitudinal
movement
• In long conduit runs to permit linear
movement caused by thermal expansion
and contraction
• On long conduit runs to prevent conduit
from buckling and ensuing circuit failures
• Indoors or outdoors where conduit
expansion occurs and there are wide
temperature ranges
• In conduit runs that cross structural
joints
• In conduit runs to prevent damage to
conduit supports such as in a building or
on a bridge
• With optional redundant visible
grounding strap

Certifications and
Compliances:
•
•
•
•
•

UL Standard: 514B
CSA Standard: C22.2 No. 18
NEC Articles 250-77 and 300-7 (b)
NEMA FB1
Wet Locations

Standard Materials and
Finishes:
Body
• Steel - electrogalvanized
• Copper-free aluminum - natural
• Feraloy® iron alloy - electrogalvanized (5"
+ 6" only)
Reducer
• 1/2" through 1" - Steel - electrogalvanized
• 11/4" through 6" - Feraloy® iron alloy electrogalvanized and aluminum paint
• Copper-free aluminum - natural
Gland Nut
• 1/2" through 1" - Steel - electrogalvanized
• 11/4" through 6" - Feraloy® iron alloy electrogalvanized and aluminum paint
• Copper-free aluminum - natural
Packing
• Teflon® (trademark of E.I. DuPont Co.)
Washer
• Steel - electrogalvanized
• Copper-free aluminum - natural
Gasket
• Vellum

Patented Design

Ordering Information
Conduit
Size

Maximum
Conduit
Movement

Cat. #

Optional
Bonding
Jumper†

A
Diameter

B
Length

Bonding
Jumper
Length

/2

4
8

XJG14
XJG18

BJ14
BJ18

1.75
1.75

6.75
10.75

20"
30"

3

/4

4
8

XJG24
XJG28

BJ24
BJ28

2.12
2.12

6.75
10.75

20"
30"

1

4
8

XJG34
XJG38

BJ34
BJ38

2.43
2.43

7.25
11.25

20"
30"

11/4

4
8

XJG44
XJG48

BJ44
BJ48

3.19
3.19

7.56
11.56

24"
30"

11/2

4
8

XJG54
XJG58

BJ54
BJ58

3.68
3.68

7.87
11.87

24"
30"

2

4
8

XJG64
XJG68

BJ64
BJ68

4.75
4.75

8.25
12.25

24"
30"

21/2

4
8

XJG74
XJG78

BJ74
BJ78

4.87
4.87

9.31
13.31

24"
36"

3

4
8

XJG84
XJG88

BJ84
BJ88

5.37
5.37

10.00
14.00

30"
36"

31/2

4
8

XJG94
XJG98

BJ94
BJ98

6.62
6.62

9.81
13.81

30"
36"

4

4
8

XJG104
XJG108

BJ104
BJ108

6.62
6.62

9.81
13.81

30"
36"

5

8

XJ128‡

—

7.64

15.50

—

6

8

XJ148‡

—

9.56

16.00

—

1

†XJG expansion couplings use a metallic bushing and ground springs to create a high integrity internal ground connection.
External ground straps offer a redundant ground path and easy visible indication of ground.
‡XJ128 and XJ148 are not internally grounded. A pair of 36" bonding jumpers are provided with fitting.

Bushing
• 1/2" through 1" - Steel - electrogalvanized
• 11/4" through 6" - Feraloy® iron alloy electrogalvanized and aluminum paint
• Copper-free aluminum - natural
Ground Springs
• Phosphor bronze - electrogalvanized
Ground Strap
• Braided tinned copper
U-Bolts
• Malleable iron – electrogalvanized

Dimensions
In Inches:

Options:
Description
Available in copper-free aluminum
Not available on 5" and 6" sizes
Hot dipped galvanized

Suffix
SA
HDG

XJG shown with optional bonding
jumper

Available with redundant† ground strap
for visible indication of grounding –
order separately (BJ Series)

Size Ranges:
• 1/2" through 6" conduit size
• 4" and 8" maximum conduit movement
130

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

XJG-EMT Conduit Expansion
Joints With Internal Grounding
For EMT Conduit

5F

Options:

Size Ranges:

XJG expansion couplings are used with
EMT Conduit:
• Without the need for an external bonding
jumper and clamps

Available with redundant† ground strap
for visible indication of grounding – order
separately (BJ Series)

• 1/ 2" through 4" conduit size
• 4" maximum conduit movement

• To couple together two (2) sections of
conduit subject to longitudinal movement

Ordering Information

5F

Applications:

• In long conduit runs to permit linear
movement caused by thermal expansion
and contraction
• On long conduit runs to prevent conduit
from buckling and ensuing circuit failures
• Indoors or outdoors where conduit
expansion occurs and there are wide
temperature ranges

Conduit
Size

Maximum
Conduit
Movement Cat. #

Optional
Bonding
Jumper

A
B
Diameter Length

/2"
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

4"
4"
4"
4"
4"
4"
4"
4"
4"
4"

BJ14
BJ24
BJ34
BJ44
BJ54
BJ64
BJ74
BJ84
BJ94
BJ104

13/4"
21/8"
27/16"
31/8"
35/8"
43/4"
47/8"
53/8"
65/8"
65/8"

1
3

• In conduit runs that cross structural joints
• In conduit runs to prevent damage to
conduit supports such as in a building or
on a bridge
• With optional redundant visible
grounding strap

Certifications and
Compliances:
•
•
•
•

XJG14 EMT
XJG24 EMT
XJG34 EMT
XJG44 EMT
XJG54 EMT
XJG64 EMT
XJG74 EMT
XJG84 EMT
XJG94 EMT
XJG104 EMT

103/4"
11"
111/2"
151/4"
151/2"
151/2"
183/4"
197/8"
211/4"
211/4"

UL Standard: 514B
CSA Standard: C22.2 No. 18
NEC Articles 250-77 and 300-7 (b)
NEMA FB1

Standard Materials and
Finishes:

XJG shown with optional bonding jumper

Body
• Steel - electrogalvanized
• Copper-free aluminum - natural
Reducer
• 1/2" through 1" - Steel - electrogalvanized
• 11/4" through 4" - Feraloy® iron alloy electrogalvanized and aluminum paint
Gland Nut
• 1/2" through 1" - Steel - electrogalvanized
• 11/4" through 4" - Feraloy® iron alloy electrogalvanized and aluminum paint
Packing
• Teflon® (trademark of E.I. DuPont Co.)
Washer
• Steel - electrogalvanized
Gasket
• Vellum
Bushing
• 1/2" through 1" - Steel - electrogalvanized
• 11/4" through 4" - Feraloy® iron alloy electrogalvanized and aluminum paint
Ground Springs
• Phosphor bronze - electrogalvanized
Ground Strap
• Braided tinned copper
U-Bolts
• Malleable iron – electrogalvanized

†XJG expansion couplings use a metallic bushing and ground springs to create a high
integrity internal ground connection. External ground straps offer a redundant ground path
and easy visible indication of ground.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

131

5F

5F

Wet Locations

XJGD Combination
Expansion/Deflection Coupling
and Expansion Joint
Internally Grounded
Ordering Information

Applications:
XJGD combination fittings are used with
rigid metal conduit and IMC:
• To accommodate axial expansion,
angular misalignment and parallel
misalignment
• To couple together two (2) sections of
conduit subject to longitudinal
movement
• To maintain a ground connection without
the need for an external bonding jumper
and clamps
• In long conduit runs to prevent conduit
from buckling and causing circuit failures
• Indoors or outdoors where conduit
expansion occurs and there are wide
temperature swings
• In conduit runs that cross structural
joints
• In conduit runs to prevent damage to
conduit supports such as in a building or
on a bridge

Maximum
Conduit
Hub Size Movement

Cat. #

A
Diameter

B
Length

1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

XJGD34
XJGD44
XJGD54
XJGD64
XJGD74
XJGD84
XJGD94
XJGD104

315/16"
41/4"
41/2"
415/16"
55/16"
515/16"
61/2"
8"

173/4"
181/8"
185/8"
191/4"
203/4"
215/8"
215/8"
273/4"

4"
4"
4"
4"
4"
4"
4"
4"

Certifications and
Compliances:
• UL Standard: 514B

Standard Materials:
• Body, Hubs, Gland Nut, Washer,
Bushing – Feraloy®
• Packing – Teflon®
• Gasket – vellum
• Ground Spring – phosphor bronze
• Outer Jacket – molded neoprene
• Jacket Clamps – stainless steel
• Inner Sleeve – molded plastic
• Ground Straps – tinned copper braid

Standard Finishes:
• Feraloy® – electrogalvanized

132

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Conduit Hubs

Cl. I, Div. 2, Groups A, B, C, D

5F

Watertight

(Also see Myers Hubs see page 211)
Ordering Information

HUB Conduit Hubs:
• Provide a convenient means for
installing a threaded conduit hub on a
junction box or device enclosure
• Are used to connect conduit to a sheet
metal or cast enclosure
• Are used with threaded rigid conduit or
IMC, steel or aluminum; indoors or
outdoors

Conduit Size

Cat. #

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

HUB1
HUB2
HUB3
HUB4
HUB5
HUB6
HUB7
HUB8
HUB9
HUB10

Features:
• Smooth insulated throat provides easier
wire pulling and protection for
conductors during installation.
• Neoprene sealing gasket provides a
watertight seal.
• Compact design permits close spacing
of conduit.
• Wide range of sizes from 1/2" to 4".

1

5F

Applications:

Dimensions
In Inches:

Certifications and
Compliances:
• UL Standard: 514B
• CSA Standard: C22.2 No. 18
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Per NEC 501-4(b), 502-4(a) and
503-3(a)

Standard Materials:
• 1/2" to 4" malleable iron

Standard Finishes:
• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint

Size Ranges:

Cat. #
HUB1
HUB2
HUB3
HUB4
HUB5
HUB6
HUB7
HUB8
HUB9
HUB10

Conduit
Size

a

b

c

d

x

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

1
11/8
13/8
11/2
15/8
111/16
23/16
27/16
27/16
29/16

11/4
19/16
17/8
25/16
21/2
3
35/8
41/4
43/4
51/4

1
13/8
15/8
2
23/8
213/16
37/16
41/16
411/16
51/16

/8
5
/32
3
/16
1
/4
1
/4
1
/4
1
/4
1
/4
5
/16
5
/16

9

1

1

/64
/4
/32
7
/16
7
/16
7
/16
7
/16
7
/16
3
/4
11/8
1
9

Dimension "x" is maximum wall thickness of box that will meet the requirement for three full
threads engagement of nipple and fitting body when liquidtight box connector or rigid
conduit hub is installed in a knockout or slip hole.

• 1/2" to 4"

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

133

5F

5F

Grounding Devices
Straps and Clamps

Applications:

GCT Grounding Connector

• GCR grounding receptacles are used to
provide static electricity grounding
connections; particularly suited for, but
not limited to, use in aircraft hangar
floors and airport aprons.
• GCT ground connector and studs are
used to provide "quick-connect" static
electricity grounding connections with
portable cable.
• GC grounding strap and clamp are
suitable for bonding and grounding
equipment in wiring systems, such as
meter circuits, service entrance
equipment, and appliances per NEC
requirements.

For Static Electricity Grounding

Cable Dia.

Cat. #

.312" to .406"

GCT8

GCT Stud*

Description
Brass

Features:
GCR grounding receptacles have:
• Grounding stud integral with housing
• Grounding stud designed to accept
standard battery clip
• Thread at bottom for attaching to 3/4"
threaded grounding rod
• Cover attached to receptacle by chain to
prevent loss of cover
• Corrosion resistant material
GCT grounding connector and studs have:
• Substantial clip tension for grounding
• Integral cable clamp to prevent cable
from breaking free of connector or
fraying at connector
• Lock washer on stud to maintain good
electrical contact
GC strap:
• Is pliable, strong and corrosion resistant
• Assures a lasting bond. Prongs on strap
clamp engage strap perforations,
preventing slippage.

GCR Receptacles

Thread
Size

Cat. #

/8 - 16

GCT2

3

*Not a replacement for grounding stud in GCR
receptacle.

GC Grounding Strap

Description

Thread Size

Cat. #

With cap and
chain

5

/16 - 18

GCR210

Strap Clamp

Used with GC102 Strap Clamp
Description
Cat. #
50' coil, 1" wide

Description

Cat. #

Brass

GC102

GC100

Dimensions
In Inches:

Certifications and
Compliances:
• UL Standard: GC strap and clamps – 467
• CSA Standard: C22.2 No. 41

Standard Materials:
• GCR – Bronze body, cap and chain;
brass grounding stud
• GCT – Bronze connector body;
aluminum cable clamp; brass stud
• Strap – flexible copper
• Clamp – brass

GCR

Standard Finishes:
• Bronze, brass, aluminum parts – natural
• Flexible copper strap – tinned

134

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Service Entrance Heads and
Replacement Covers

5F

F Service Heads

F type service entrance heads are used:
• For overhead service entrance to
buildings
• With threaded rigid, threadless rigid or
threadless thinwall (EMT) conduit and
rigid conduit masts

Threaded Rigid

5F

Applications:

Features:
Two types available:
• Threaded rigid – threads to conduit.
• Threadless rigid or EMT – clamps to
conduit.
• Available knockouts in covers allow use
with variety of sizes and numbers of
wires.
• Simple construction and easy assembly.
• Consists of only two pieces plus the
insulating knockout cover.
• Easy to install.

Certifications and
Compliances:
• UL Standard: 514B
• CSA Standard: C22.2 No. 18

Standard Materials:
• Copper-free aluminum

Standard Finishes:
• Natural

/2" size

/4" – 2" size

1

3

/2" size

1

Conduit
Size

Number and Dia. of Cover Knockouts

Cat. #

/2

6 – 9/32

F186

CF690

/4

2 – 3/8 and 3 – 13/32

F285

5H

1

2 – 7/16 and 3 – 1/2

F385

5 NS

11/4

2 – 27/64 and 3 – 5/8

F485

5 NL

11/2

2 – 27/64 and 3 – 5/8

F585

5 NL

2

2 – 7/8, 1 – 13/16, 1 – 11/16,1 – 9/16 and 1 – 21/32

F686

CF60

21/2

2 – 17/16, 1 – 17/32, 1 – 11/64, 1 – 61/64 and 1 – 55/64

F766

CF707

3

2 – 17/16, 1 – 17/32, 1 – 11/64, 1 – 61/64 and 1 – 55/64

F866

CF707

31/2

3 – 13/4, 1 – 17/16, 1 – 15/16 and 1 – 13/16

F966

CF708

4

3 – 13/4, 1 – 17/16, 1 – 15/16 and 1 – 13/16

F1066

CF708

1
3

Replacement
Cover Cat. #

Overall Dimensions of Replacement Covers
for F Series Service Heads
Cat. #

Dim.

CF690
5H
5 NS
5 NL
CF60
CF707
CF708

11/2 dia.
131/32 dia.
215/64 dia.
219/32 dia.
33/16 dia.
713/16 × 311/16
101/4 × 43/4

Clamp Type
Threadless Rigid or EMT

Conduit
Size

Number and Dia. of Cover Knockouts

Cat. #

Replacement
Cover Cat. #

3

/4

2 – 3/8 and 3 – 13/32

F235

5H

1

2 – 7/16 and 3 – 1/2

F335

5 NS

11/4

2 – 27/64 and 3 – 5/8

F435

5 NL

11/2

2 – 27/64 and 3 – 5/8

F535

5 NL

2

2 – 7/8, 1 – 13/16, 1 – 11/16, 1 – 9/16 and 1 – 21/32

F636

CF60

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

135

LNR Conduit Liner

5F

5F

Applications:
LNR conduit liners are installed in rigid metal conduit or IMC:
• To provide a smooth wire entry from conduit into enclosures to
protect wires from abrasion as they are pulled.
• With thin wall or thick wall enclosures.
• Entering drilled and tapped openings or slip holes.
• Entering an enclosure vertically or horizontally.
• Regardless of where the conduit ends in relation to the
enclosure wall.

Features:

Ordering Information

•
•
•
•

Cat. #

Size

A

B

C

D

LNR1
LNR2
LNR3
LNR4
LNR5
LNR6
LNR7
LNR8
LNR9
LNR10

/2"
3
/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
4"

13/16"
19/16"
21/16"
21/16"
29/16"
29/16"
27/8"
27/8"
31/16"
31/16"

/8"
11/8"
13/8"
13/4"
2"
27/16"
27/16"
39/16"
41/16"
49/16"

/8"
13
/16"
11/16"
13/8"
15/8"
21/16"
21/4"
31/16"
39/16"
4"

9

UL listed and CSA certified.
No need for threaded bushings, reducers, or special machining.
Corrosion and heat resistant polypropylene material.
Smooth flange providing easy wire pulling and protects conductors
being installed.
• Space saving.
• Molded ribs ensure a tight fit, preventing the liner from sliding out
while conductors are being pulled.
• Quick and easy to install.

Certifications and Compliances:
•
•
•
•

NEC Article 346-8
UL Standard 514B
CSA Standard C22.2 No. 18
U.S. Patent No. 5,383,688

1

Dimensions
In Inches:

Standard Materials:
• Polypropylene

Standard Finishes:
• Natural (clear)

Sizes:
• 1/2" through 4"

136

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

7

5

/16"
/4"
/8"
11/4"
17/16"
17/8"

3
7

27/8"
33/8"
37/8"

Conduit Seals, Breathers and Drains
Hazardous

6F

Page No.

Application/Selection

see page 138

Breathers & Drains
Standard
ECD Series
CD Series (Non-hazardous)

see page 158
see page 159

Universal
ECD Series

see page 158

Sealing Compound
Chico® A
Chico® SpeedSeal™

see pages 155–156
see pages 155–156

Sealing Fiber
Chico® X

see pages 155–156

Sealing Fittings Tool Kit
EYS Tool Kit

see page 157

Seals
Drains
EYD Series
EZD Series
EYDX Series

see page 144
see page 145
see page 147

Elbows
EYS

see page 140

Horizontal/Vertical
ES Series
EYS Series
EYS Series with ATEX
EYSA Series
EYSX Series

see
see
see
see
see

page
page
page
page
page

149
140
142
143
146

Inspection
EZD Series

see page 145

Retrofit
EYSR Series

see page 148

Universal
EZS Series
EZS Series with ATEX

see page 141
see page 142

Secondary Process Seals
Ultra High Pressure Seal
Secondary Process Seal Assembly with Rupture Sensor

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

see page 150
see pages 151–154

Copyright© 2013 Eaton’s Crouse-Hinds Business

137

6F

Description

6F

Conduit Seals, Breathers and Drains

6F

Application and Selection

Applications:
Seals:
• Seals are installed in conduit runs to
prevent the passage of gases, vapors or
flames from one portion of the electrical
installation to another through the
conduit, limiting any explosion to the
enclosure and preventing
precompression or "pressure piling."
• While not a National Electrical Code
requirement, many engineers consider it
good practice to sectionalize long
conduit runs by inserting seals not more
than 50' to 100' apart, depending on the
conduit size, to minimize the effects of
"pressure piling."

EZS Horizontal seal

EYSR Retrofit seal

Breathers:
• Breathers (vents), are installed in the top
of enclosures to provide ventilation to
minimize condensation in enclosures.
Drains:
• Drains are used in humid atmospheres
or in wet locations where it is likely that
water can gain entrance to the interiors
of enclosures or raceways. The
raceways should be inclined so that
water will not collect in enclosures or on
seals, but will be led to low points where
it may pass out through ECD drains.

EYS Horizontal seal

• Frequently the arrangement of raceway
runs makes this method impractical if
not impossible. In such instances, EZD
or EYD drain seal fittings should be
used. These fittings prevent harmful
accumulations of water above the seal.

Considerations for
Selection:
Seals:
• Select the proper sealing fitting for the
hazardous vapor involved; i.e., Class I,
Division 1 & 2, Groups A, B, C or D.
• Select the appropriate seal for new or
retrofit installations.
• Select a sealing fitting for the proper use
in respect to mounting position. This is
particularly critical when the conduit
runs between hazardous and nonhazardous areas. Improper positioning
of a seal may permit hazardous gases or
vapors to enter the system beyond the
seal and permit them to escape into
another portion of the hazardous area or
to enter a non-hazardous area. Some
seals are designed to be mounted in any
position; others are restricted to vertical
mounting.

Drains:
• In locations which are usually
considered dry, surprising amounts of
water frequently collect in conduit
systems. No conduit system is airtight,
therefore, it may "breathe". Alternate
increases and decreases in temperature
and/or in barometric pressure, due to
weather changes or due to the nature of
the process carried on in the location
where the conduit is installed, will cause
"breathing," resulting in condensation
and water accumulation.
• In view of this likelihood, it is therefore
good practice to insure against such
water accumulations and probable
subsequent insulation failures by
installing breathers, drain seals, or
inspection seals, even though conditions
prevailing at the time of planning or
installing do not indicate their need.

EYS 1 Vertical sealing

Options:
Description
Corro-free™ epoxy powder coat

The amount of Chico® fiber and compound required for
any seal is determined by volume, hub size and mounting
position of the seal.

138

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Suffix
S752

6F

Conduit Seals, Breathers and Drains
Shape Selector Chart
Quick Selector Chart

EYS /
EYSA

Page
see
page 140

Series
EZD

EYS
see
Elbow Seal page 140 ES

Page Series
see ECD
page 145 Standard

see
page 149

Page Series
see ECD
page 158 Universal

EYD

Page Series
see
page 158 EYSX

see
page 146 EYDX

see
page 147

see
page 144 EYSR

see
page 144 EZS

see
page 141

Page Series

Page

Quick Selector Chart
NEC
Hazardous Group

For Conduit
Angle

Seal

Class I, Groups A, B, C, D
Class II, Groups E, F, G

Vertical and Horizontal

EYS ATEX

Seal

Ex II 2 G EEx d IIC

Vertical and Horizontal

EYSA

Seal

Flameproof, Exd, IIC

Vertical and Horizontal

EYS 29

Elbow Seal

Class I, Groups C, D
Class II, Groups E, F, G

90° turn

EYSR

Retrofit Seal/Drain Seal*

Class I, Div. 2, Groups C, D
Class II, Div. 2, Groups E, F, G
Class III

Vertical and Horizontal

EYSX

Expanded Fill Sealing
Fittings

Class I, Groups B, C, D
Class II, Groups E, F, G

Vertical and Horizontal

EZS

Seal

Class I, Groups C, D
Class II, Groups E, F, G

All

EZS ATEX

Seal

Ex II 2 G EEx d IIC

All

ES

Sealing Hub

Class I, Groups C, D

Vertical

EYD

Seal and Drain

Class I, Groups B, C, D
Class II, Groups F, G

Vertical

EYDX

Expanded Fill Sealing
Fittings and Drain

Class I, Groups B, C, D
Class II, Groups F, G

Vertical

EZD

Inspection Seal and Drain –
Inspection Seal only

Class I, Groups C, D
Class II, Groups E, F, G

Vertical

ECD

Standard Breather only
Drain only

Class I, Groups B, C, D
Class II, Groups E, F, G
Class III

ECD

Universal Drain – Breather

Class I, Groups C, D
Class II, Groups F, G

CD

Non-hazardous Drain

UHPS

Ultra High Pressure Seal

Class I, Div. 1, Groups B, C, D
Certified to CSA Standards through QPS

SPSR

Secondary Process Seal with
Rupture Sensor

Class I, Div. 1 & 2, Groups B, C, D
Class I, Zone 1 & 2 IIB + H2
Class II, Div. 1 & 2, Groups E, F, G

Series

Description

EYS

*Drain purchased separately.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

139

6F

Series

6F

Conduit Sealing Fittings

Cl. I, Div. 1 & 2, Groups A, B, C, D Explosionproof
Dust-Ignitionproof
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

6F

Chico Sealing Compound
and Fiber see pages 155–156
Applications:

Standard Finishes:

EYS and EZS sealing fittings:
• Restrict the passage of gases, vapors or flames from one portion
of the electrical installation to another at atmospheric pressure and
normal ambient temperatures
• Limit explosions to the sealed off enclosure
• Limit precompression or pressure "piling" in conduit systems
Sealing fittings are required:
• At each entrance to an enclosure housing an arcing or sparking
device when used in Class I, Division 1 and 2 hazardous locations.
To be located as close as practicable and, in no case, more than
18" from such enclosures
• At each conduit entrance of 2" size or larger to an enclosure or
fitting housing terminals, splices or taps when used in Class I,
Division 1 hazardous locations. To be located as close as
practicable and, in no case, more than 18" from such enclosures
• In conduit systems when leaving Class I, Division 1 or Division 2
hazardous locations
• In cable systems when the cables either do not have a
gas/vaportight continuous sheath or are capable of transmitting
gases or vapors through the cable core when those cables leave
the Class I, Division 1 or Division 2 hazardous locations

• Feraloy iron alloy and ductile iron – electrogalvanized and
aluminum acrylic paint
• Steel – electrogalvanized

Options:
Description
Copper-free aluminum bodies, nipples and enclosures

Size Ranges:
• 1/2" – 6"

Ordering Information - EYS

Vertical
female

Features:
EYS and EZS sealing fittings include:
• Minimum turning radius
• Large openings with threaded closures to provide easy access to
conduit hubs for making dams
• Integral bushings in conduit hubs to protect conductor insulation
from damage
• Taper-tapped hubs to ensure ground continuity
EYS sealing fittings are available for installation in either vertical only
or in both horizontal or vertical positions.
EZS sealing fittings for installation at any angle; the covers with
opening for sealing compound can be properly positioned to accept
the compound.

Certifications and Compliances:

Vertical
male &
female

Hub
Size

Female
Hub Cat. #

Male & Female
Hub Cat. #

Approximate Internal
Volume in Cubic Inches

/2
/4
1

EYS1*
EYS2*
EYS3*

EYS16*
EYS26*
EYS36*

1
2
33/4

1
3

For Sealing in Vertical or Horizontal Positions
Approximate Internal
Volume in Cubic
Inches
Hub
Size

Female Hub
Cat. #

Male & Female
Hub Cat. #

Vertical

Horizontal

/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

EYS11*
EYS21*
EYS31*
EYS41
EYS51
EYS61
EYS71
EYS81
EYS91
EYS101

EYS116*
EYS216*
EYS316*
EYS416
EYS516
EYS616
EYS716
EYS816
EYS916
EYS1016

1
2
3
6
103/4
19
251/2
56
72
95

1
2
33/4
8
121/4
223/4
30
641/2
82
110

Dimensions (In Inches)
EYS 16 Series
Size
1
/2
3
/4
1

EYS 116 Series

a

b

Turning
Radius

39/32
312/16
45/16

11/4
11/2
13/4

15/8
129/32
23/8

EYS 46 Series

Sealing fittings are approved for use in hazardous locations only when Chico X fiber and
Chico A sealing compound or Chico SpeedSeal are used to make the seal.

Standard Materials:
• Bodies – Feraloy® iron alloy and/or ductile iron
• Plugs – Feraloy iron alloy and/or steel
• Removable nipples – steel

11/4
11/2
2
21/2
3
31/2
4
5
6

51/16
51/2
61/4
71/2
81/2
93/16
93/4
111/16
121/8

23/16
27/16
3
31/2
41/4
43/4
51/4
61/2
75/8

US: 1-866-764-5454

CAN: 1-800-265-0502

a

b

Turning
Radius

311/16
311/16
45/16

11/4
11/2
13/4

15/32
11/4
13/8

EYS 116 Series
123/32
21/16
25/16
211/16
35/16
37/16‡
311/16‡
419/32‡
511/32‡

‡With cover removed.
www.crouse-hinds.com

Vertical or
horizontal
male & female

*Available in copper-free aluminum – to order, add suffix SA to Cat. No.

®

140

Vertical or
horizontal
female

For Sealing in Vertical Positions Only

1

• NEC/CEC:
EYS1-3, 11-31, 16-36, 116-316
Class I, Division 1 & 2, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EYS41-101, 416-1016
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EYS29, 4-014, 46-0146
EZS1-8, 16-86
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2

Suffix
SA

Copyright© 2013 Eaton’s Crouse-Hinds Business

51/16
51/2
61/4
71/2
81/2
93/16
93/4

23/16
27/16
3
31/2
41/4
43/4
51/4

123/32
21/16
25/16
211/16
35/16
37/16‡
311/16‡

Conduit Sealing Fittings
Chico Sealing Compound
and Fiber see pages 155–156
Ordering Information - EYS

6F

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Vertical or horizontal male & female

6F

Ordering Information - EZS

Male & female hub

For Sealing in Vertical or Horizontal Positions
Hub
Size

Female
Hub
Cat. #

Male &
Female
Hub
Cat. #

Vert.

Horiz.

11/4
11/2
2
21/2
3
31/2
4
5
6

EYS4*
EYS5*
EYS6*
EYS7*
EYS8*
EYS9*
EYS10*
EYS012
EYS014

EYS46*
EYS56*
EYS66*
EYS76*
EYS86*
EYS96*
EYS106*
EYS0126
EYS0146

6
103/4
19
251/2
56
72
95
200
290

8
121/4
223/4
30
641/2
82
110
222
315

For Sealing at Any Angle

Approximate Internal
Volume in Cubic Inches

Male &
Female
Hub
Cat. #

Approximate Internal
Volume in Cubic Inches

Hub
Size

Female
Hub
Cat. #

Vert.

Horiz.

/2
3
/4
1
11/4
11/2
2
21/2
3

EZS1
EZS2
EZS3
EZS4
EZS5
EZS6
EZS7
EZS8

EZS16
EZS26
EZS36
EZS46
EZS56
EZS66
EZS76
EZS86

61/4
61/2
101/4
121/2
141/2
46
55
90

61/4
61/2
101/4
121/2
141/2
46
55
90

1

*Available in copper-free aluminum – to order, add suffix SA to Cat. No.

Dimensions

EYS

In Inches

Elbow seal

For Sealing in Vertical Positions
Hub
Size

Cat. #

Approximate
Internal Volume
in Cubic Inches

/4

EYS29

13/4

3

EYS 16 Series

EYS 46 and
EYS 116 Series

EZS Series

EZS Series

EYS Elbow Seal
Size
3
/4

EYS Elbow Seal

a

b

Turning Radius
(Vertical)

311/16

13/4

17/8

Size
1
/2
3
/4
1
11/4
11/2
2
21/2
3

a

b

c

Turning
Radius†

43/16
43/16
415/16
51/16
53/16
71/16
715/16
85/8

35/8
35/8
331/32
413/32
49/16
513/32
527/32
61/2

21/2
21/2
3
3
31/4
53/16
53/16
57/8

17/8
17/8
21/8
25/16
211/32
39/32
33/8
37/8

†With cover removed.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

141

6F

Conduit Sealing Fittings

Ex II 2 G EEx d IIC

Zone 1 and 2

6F

for IEC Applications
Applications:
EYS and EZS sealing fittings:
• Restrict the passage of gases, vapors or flames from one portion
of the electrical installation to another at atmospheric pressure and
normal ambient temperatures
• Limit explosions to the sealed off enclosure
• Limit precompression or pressure "piling" in conduit systems
Sealing fittings are required:
• At each entrance to an enclosure housing an arcing or sparking
device when used in Class I, Division 1 and 2 hazardous locations.
To be located as close as practicable and, in no case, more than
18" from such enclosures
• At each conduit entrance of 2" size or larger to an enclosure or
fitting housing terminals, splices or taps when used in Class I,
Division 1 hazardous locations. To be located as close as
practicable and, in no case, more than 18" from such enclosures
• In conduit systems when leaving Class I, Division 1 or Division 2
hazardous locations
• In cable systems when the cables either do not have a
gas/vaportight continuous sheath or are capable of transmitting
gases or vapors through the cable core when those cables leave
the Class I, Division 1 or Division 2 hazardous locations

Features:
EYS and EZS sealing fittings include:
• Minimum turning radius
• Large openings with threaded closures to provide easy access to
conduit hubs for making dams
• Integral bushings in conduit hubs to protect conductor insulation
from damage
• Taper-tapped hubs to ensure ground continuity
EYS sealing fittings are available for installation in either vertical only
or in both horizontal or vertical positions.
EZS sealing fittings for installation at any angle; the covers with
opening for sealing compound can be properly positioned to accept
the compound.

EZS

EYS

Certifications and Compliances:
• IEC:
Ex II 2 G EEx d IIC
EC-Type examination certificate LOM 03 ATEX 2108
• IP67 according to EN 60529

Standard Materials:
• Bodies – Light alloy, natural finish
• Plugs – Light alloy, natural finish
• Removable nipples – Light alloy, natural finish

Size Ranges:
• EYS - 1/2" – 4"
• EZS - 1/2" – 1"

Ordering Information:
Series

Mounting Direction

Hub Size

Cat. #

EYS
EYS
EYS
EYS
EYS
EYS
EZS
EZS
EZS
EZS

Vertical
Vertical
Vertical
Vertical
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal
Horizontal

1

/2" NPT
3
/4" NPT
1" ISO
1" NPT
11/2" NPT
2" NPT
1
/2" NPT
3
/4"NPT
1" ISO
1" NPT

NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR
NOR

142

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

000
000
000
000
000
000
000
000
000
000

002
002
002
002
002
002
002
002
002
002

Copyright© 2013 Eaton’s Crouse-Hinds Business

220
220
220
220
220
220
220
220
220
220

117
125
133
620
160
168
216
224
232
729

Conduit Sealing Fittings

Zone 1
Zone 2

Zone 21
Zone 22

6F

EYSA Flameproof Sealing Fitting
6F

Applications:
EYSA sealing fittings:
• Restrict the passage of gases, vapors,
or flames from one portion of the
electrical installation to another at
atmospheric pressure and normal
ambient temperatures
• Limit explosions to the sealed off
enclosure
• Prevent pre-compression or "pressure
piling" in conduit systems
Sealing fittings are required:
• At each entrance to an enclosure
housing an arcing or sparking device
when used in Zone 1, hazardous
locations to be located as close as
practicable and in no case more than
450mm from such enclosures
• In conduit systems when leaving the
Zone 1 area and entering an area of
lesser hazard

Features:
• Minimum turning radius
• Large openings with threaded closures
to provide easy access to conduit hubs
for making dams
• Integral bushings to protect conductor
insulation from damage
• Removable male nipple supplied when
male and female hub style is ordered

Certifications and
Compliances:

Ordering Information:

• Type of Protection: Ex d, DIP A21,
T60ºC, IP66
• Degree of Protection: IP66
• Gas Group: IIC
• Approvals: IEC Ex TSA07.0015-1

Standard Materials:
• Bodies - copper-free aluminum
• Removable nipples and plugs - brass

Standard Finishes:
• Body - polyurethane gray
• Nipples and plugs - natural

Entry Size

Female

Male &
Female

Weight of
Sealing
Compound
per Seal (g)

20mm/20mm
25mm/25mm
32mm/32mm
40mm/40mm
50mm/50mm
3
/4" BSP/3/4" BSP
20mm/1/2" BSP
20mm/3/4" BSP
25mm/1/2" BSP
25mm/3/4" BSP

EYSA1M
EYSA2M
EYSA3M
EYSA4M
EYSA5M
EYSA2B
EYSA11MB
EYSA12MB
EYSA21MB
EYSA22MB

EYSA16M
EYSA26M
EYSA36M
EYSA46M
EYSA56M
EYSA26B
-

50
100
188
406
550
100
50
50
100
100

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Weight of
Chico X
Fiber
per Seal (g)
1
2
3.5
7
14
2
1
1
2
2

Copyright© 2013 Eaton’s Crouse-Hinds Business

143

6F

Cl. I, Div. 1 & 2, Groups B, C, D§ Explosionproof
Dust-Ignitionproof
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Conduit Sealing Fittings
With Drains

6F

Applications:

Standard Finishes:

Options:

EYD drain and EZD drain and inspection
sealing fittings:
• Restrict the passage of gases, vapors or
flames from one portion of the electrical
installation to another at atmospheric
pressure and normal ambient
temperatures
• Limit explosions to the sealed-off
enclosure
• Prevent precompression or "pressure
piling" in conduit systems
Drain sealing fittings are installed in vertical
conduit runs and at low points in conduit
systems to prevent accumulation of
condensate above seal.
For sealing fittings requirements
see page 139.

• Feraloy iron alloy and ductile iron –
electrogalvanized and aluminum acrylic
paint
• Copper-free aluminum – natural
• Stainless steel – natural
• Steel – electrogalvanized

Description
Copper-free aluminum bodies,
nipples and enclosures

Suffix
SA

Size Ranges:
• EYD – 1/2" – 4"
• EZD – 1/2" – 2"

Ordering Information - EYD

Features:
EYD and EZD drain sealing fittings include:
• Drain to provide continuous, automatic
drainage of condensate
• Large openings with threaded closures
to provide easy access to conduit hubs
for making dams
• Integral bushings to protect conductor
insulation from damage
• Taper-tapped hubs to ensure ground
continuity
EZD drain and inspection sealing fittings
also include:
• Removable covers for periodic
inspection of seals
• Barrier for sealing compound easily
installed after dams are made and
before compound is poured.

Certifications and
Compliances:

/2" – 1"
Male &
female hub
1

1
/2" – 1"
Female hub

11/4" – 4"
Male &
female hub

11/4" – 4"
Female hub

Hub
Size

Female
Hub
Cat. #

Male &
Female
Hub
Cat. #

Female
Hub
Cat. #

Male &
Female
Hub
Cat. #

Approximate
Internal Volume
in Cubic Inches

/2
/4
1
11/4
11/2
2
21/2
3
31/2
4

EYD1*
EYD2*
EYD3*
EYD4*
EYD5*
EYD6*
EYD7*
EYD8*
EYD9*
EYD10*

EYD16*
EYD26*
EYD36*
EYD46*
EYD56*
EYD66*
EYD76*
EYD86*
EYD96*
EYD106*

EYD11
EYD21
EYD31
EYD41
EYD51
EYD61
EYD71
EYD81
EYD91
EYD101

EYD116
EYD216
EYD316
EYD416
EYD516
EYD616
EYD716
EYD816
EYD916
EYD1016

1
2
33/4
8
103/4
20
35
57
75
105

1
3

Dimensions
In Inches
EYD Drain Seal

• NEC/CEC:
EYD11-101, 116-1016
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EYD1-10, 16-106,
EZD10-60, 111-611
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2

Size
1
/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

a

b

Turning
Radius

39/32
311/16
45/16
51/16
51/2
61/4
71/2
81/2
93/16
93/4

11/4
11/2
23/16
23/16
27/16
3
31/2
41/4
43/4
51/4

15/8
129/32
23/8
1-27/32†
2-1/16†
2-5/16†
2-11/16†
3-5/16†
3-7/16†
3-1/2†

Standard Materials:
EYD 1/2" – 1"

EYD 11/4" – 4"

• Bodies, and inspection or drain covers –
Feraloy® iron alloy and/or ductile iron
• Closure for drain – copper-free
aluminum or ductile iron
• Small closure plug – Feraloy iron alloy
and/or steel
• Drain – stainless steel
• Removable nipples – steel

†With cover removed.
*Available in copper-free aluminum – to order, add suffix SA to Cat. No.
Sealing Fittings are approved for use in hazardous locations only when Chico® X fiber and Chico A sealing compound or
Chico SpeedSeal are used to make the seal.
§See Certifications and Compliances for classification of each product.

144

CAN: 1-800-265-0502

www.crouse-hinds.com

US: 1-866-764-5454

Copyright© 2013 Eaton’s Crouse-Hinds Business

Conduit Sealing Fittings with
Drain and Inspection Cover
Chico Sealing Compound and Fiber
see pages 155–156

6F

Dimensions

6F

EZD With Drain Cover

Cl. I, Div. 1 & 2, Groups C, D Explosionproof
Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof
Cl. II, Div. 2, Groups F, G
Cl. III

In Inches:

Hub
Size

Cat. #

Approximate
Internal Volume
in Cubic Inches

/2
3
/4
1
11/4
11/2
2

EZD111
EZD211
EZD311
EZD411
EZD511
EZD611

5
6
10
11
13
40

1

EZD Drain and Inspection Seals
Size
1
/2
3
/4
1
11/4
11/2
2

a

b

Drain Cover c

Turning Radius†

43/16
43/16
415/16
415/16
53/16
71/8

3
3
31/2
31/2
31/2
59/16

33/8
35/8
37/8
45/16
49/16
51/4

21/16
23/16
27/16
25/8
211/16
311/16

†With cover removed.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

145

EYSX Expanded Fill
Sealing Fittings

6F

6F

Chico Sealing Compound and
Fiber see pages 155–156
Applications:
EYSX Expanded Fill Sealing Fittings:
• Restrict the passage of gases, vapors or
flames from one portion of the electrical
installation to another at atmospheric
pressure and normal ambient
temperatures
• Limit explosions to the sealed-off
enclosure
• Limit precompression or "pressure
piling" in conduit systems
• Provide 40% wire fill capacity to allow
uninterrupted runs in a conduit system
Sealing fittings are required:
• At each entrance to an enclosure
housing an arcing or sparking device
when used in Class I, Division 1 and 2
hazardous locations. To be located as
close as practicable and, in no case,
more than 18" from such enclosures
• At each entrance of 2" size or larger to
an enclosure or fitting housing terminals,
splices or taps when used in Class I,
Division 1 hazardous locations. To be
located as close as practicable and, in
no case, more than 18" from such
enclosures
• In conduit systems when leaving Class I,
Division 1 or 2 hazardous locations
• In cable systems when the cables either
do not have a gas/vaportight continuous
sheath or are capable of transmitting
gases or vapors through the cable core
when those cables leave the Class I,
Division 1 or 2 hazardous locations

Features:
EYSX Expanded Fill Sealing Fittings
provide:
• A 40% wire fill capacity for expanded fill
sealing
• Large openings with threaded closures
to provide easy access to conduit hubs
for making dams
• Integral bushings in conduit hubs to
protect conductor insulation from
damage
• Taper-tapped hubs to ensure ground
continuity
• Minimum turning radius
EYSX Expanded Fill Sealing Fittings are
available for installation in both horizontal
or vertical positions.

Certifications and
Compliances:
• NEC/CEC:
EYSX11 – EYSX81
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

146

www.crouse-hinds.com

US: 1-866-764-5454

Explosionproof
Dust-Ignitionproof

Cl. I, Div. 1 & 2, Groups B, C, D§
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

EYSX9, EYSX10, EYSX1 SA – EYSX10 SA
Class I, Division 1 and 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Standard Materials:
• Bodies – Feraloy® iron alloy and/or
ductile iron or copper-free aluminum
(SA Suffix)
• Closures – Feraloy iron alloy and/or steel
or copper-free aluminum (SA Suffix)

Standard Finishes:
• Feraloy iron alloy and ductile iron –
electrogalvanized and aluminum acrylic
paint
• Steel – electrogalvanized
• Copper-free aluminum – natural

Options:
Description
Copper-free aluminum bodies and
enclosures

Suffix
SA

Size Ranges:

Vertical or horizontal female
Sealing fittings are approved for use in hazardous
locations only when Chico® X fiber and Chico A sealing
compound or Chico SpeedSeal are used to make the
seal.

Dimensions
In Inches:

• 1/2" – 4"

Ordering Information
For Sealing in Vertical or
Horizontal Positions
Internal Volume
Hub Female Hub
in Cubic Inches
Size Cat. #
Vertical Horizontal
/2
/2
/4
3
/4
1
1
11/4
11/4
11/2
11/2
2
2
21/2
21/2
3
3
31/2
31/2
4
4
1
1
3

EYSX11*
EYSX1 SA
EYSX21*
EYSX2 SA
EYSX31
EYSX3 SA
EYSX41
EYSX4 SA
EYSX51
EYSX5 SA
EYSX61
EYSX6 SA
EYSX71
EYSX7 SA
EYSX81
EYSX8 SA
EYSX9*
EYSX9 SA
EYSX10*
EYSX10 SA

2
2
3
3
6
6
19
19
19
19
56
56
72
72
95
95
200
200
200
200

2
2
33/4
33/4
8
8
223/4
223/4
223/4
223/4
641/2
641/2
82
82
110
110
222
222
222
222

NPT
Size
1
/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4

A

B

Turning
Radius

311/16
45/16
51/16
61/4
61/4
81/2
93/16
93/4
111/16
111/16

11/2
13/4
23/16
3
3
41/4
43/4
51/4
61/2
61/2

11/4
13/8
123/32
25/16
25/16
35/16
3-7/16‡
3-11/16‡
4-19/32‡
4-19/32‡

§ See Certifications and Compliances for classsification
of each product.
‡With plug cover removed.
*Feraloy®

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

EYDX Expanded Fill Sealing
Fittings With Drains

Cl. I, Div. 1 & 2, Groups B, C, D§
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Chico Sealing Compound and Fiber
see pages 155–156

Standard Finishes:

EYDX Expanded Fill Sealing Fittings with
drains:
• Restrict the passage of gases, vapors or
flames from one portion of the electrical
installation to another at atmospheric
pressure and normal ambient
temperatures
• Limit explosions to the sealed-off
enclosure
• Prevent precompression or "pressure
piling" in conduit systems
• Provide 40% wire fill capacity to allow
uninterrupted runs in a conduit system
Drain sealing fittings are installed in vertical
conduit runs and at low points in conduit
systems to prevent accumulation of
condensate above seal.
For sealing fittings requirements
see page 139.

• Feraloy iron alloy and ductile iron –
electrogalvanized and aluminum acrylic
paint
• Copper-free aluminum – natural
• Stainless steel – natural
• Steel – electrogalvanized

Features:
EYDX Expanded Fill drain sealing fittings
provide:
• A 40% wire fill capacity for expanded fill
sealing
• Drain to provide continuous, automatic
drainage of condensate
• Large openings with threaded closures
to provide easy access to conduit hubs
for making dams
• Integral bushings to protect conductor
insulation from damage
• Taper-tapped hubs to ensure ground
continuity

Certifications and
Compliances:
• NEC/CEC:
EYDX11 – EYDX81
Class I, Division 1 and 2,
Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
EYDX1 SA – EYDX8 SA
Class I, Division 1 and 2, Groups C, D
Class II, Division 1, Groups F, G
Class II, Division 2, Groups F, G
Class III
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

6F

Applications:

6F

Explosionproof
Dust-Ignitionproof

Options:
Description
Copper-free aluminum bodies and
enclosures

Suffix
SA

Size Ranges:
• EYDX – 1/2" – 3"

/2" – 3/4"

1" – 3"

1

Sealing Fittings are approved for use in hazardous
locations only when Chico® X fiber and Chico A sealing
compound or Chico SpeedSeal are used to make the
seal.

Ordering Information

Dimensions

Hub Female Hub
Size Cat #

Internal Volume
in Cubic Inches

In Inches:

/2
/2
3
/4
3
/4
1
1
11/4
11/4
11/2
11/2
2
2
21/2
21/2
3
3

2
2
33/4
33/4
8
8
20
20
20
20
57
57
75
75
105
105

1
1

EYDX11*
EYDX1 SA
EYDX21*
EYDX2 SA
EYDX31
EYDX3 SA
EYDX41
EYDX4 SA
EYDX51
EYDX5 SA
EYDX61
EYDX6 SA
EYDX71
EYDX7 SA
EYDX81
EYDX8 SA

§ See Certifications and Compliances for classification of
each product.
* Feraloy®

EYDX NPT
Size
1
/2
3
/4
1
11/4
11/2
2
21/ 2
3

A

B

Turning
Radius

311/16
45/16
51/16
61/4
61/4
81/2
93/16
93/4

13

/4
23/16
23/16
3
3
41/4
43/4
51/4

129/32
23/8
1-27/32†
2-5/16†
2-5/16†
3-5/16†
3-7/16†
3-1/2†

†With drain cover removed.

Standard Materials:
• Bodies and drain covers – Feraloy® iron
alloy, and ductile iron or copper-free
aluminum (SA Suffix)
• Closure for drain – copper-free aluminum
or malleable iron
• Small closure plug – Feraloy iron alloy
and/or steel or copper-free aluminum
(SA Suffix)
• Drain – stainless steel

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

147

6F

EYSR Retrofit Sealing Fitting

Cl. I, Div. 2, Groups C, D
Cl. II, Div. 2, Groups E, F, G
Explosionproof
Dust-Ignitionproof

6F

Chico Sealing Compound
and Fiber see pages 155–156
Applications:

Standard Finishes:

Options:

EYSR retrofit sealing fittings are installed:
• In rigid metal conduit systems in Class I,
Division 2 hazardous locations
• To replace installed Eaton's CrouseHinds type EYS or EYD sealing fittings
• Without disassembly of the conduit
system
• In vertical or horizontal positions,
indoors or outdoors
• To restrict the passage of gases, vapors,
or flames from one portion of the
electrical system to another at
atmospheric pressures and normal
ambient temperatures
• To limit explosions to the sealed-off
enclosure
• To limit precompression or "pressure
piling" in the conduit system
• To prevent accumulation of water in the
conduit system when installed with an
ECD15 drain

• Feraloy iron alloy – electrogalvanized
and aluminum acrylic paint
• Steel – electrogalvanized
• Gasket – natural

Description
Copper-free aluminum

Suffix
SA

Size Ranges:
• 3/4" – 4"

Features:
• Seal may be installed in the existing
conduit run without disassembly of the
conduit system saving time and labor
• Overall length and spacing requirements
do not exceed those of standard EYS
seals; permits close nesting of seals
• Pipe plugs permit the installation of a
standard ECD15 drain fitting (order
separately) for use in vertical conduit
runs to drain any water that might
accumulate in the conduit system
• Steel set screws provide grounding
continuity
• Suitable for vertical and horizontal
installations for indoor and outdoor
applications
• Available in 3/4" to 4" NPT sizes

Certifications and
Compliances:
• NEC:
Class I, Division 2, Groups C, D
Class II, Division 2, Groups E, F, G
• UL Standard: 1203
• CEC:
Class I, Division 1, Groups C, D
Class II, Division 1, Groups E, F, G
• CSA Standard: C22.2 No. 30

Ordering Information

Hub Size

Cat. #

Approximate Internal
Volume in
Cubic Inches*
Vert.
Horiz.

/4
1
11/4
11/2
2
21/2
3
31/2
4

EYSR2
EYSR3
EYSR4
EYSR5
EYSR6
EYSR7
EYSR8
EYSR9
EYSR10

31/2
43/4
7
121/4
253/4
48
861/2
147
186

3

53/4
91/2
131/2
241/4
401/2
751/2
126
210
252

Approximate Amount
(oz.) of Fiber
per Hub
Vert.
Horiz.
/16
/8
1
/4
1
/2
1
11/2
2
41/2
41/2

/8
/4
/2
1
2
3
4
9
9

1

1

1

1
1

*Use the approximate internal volume in cubic inches to determine how much Chico A sealing compound is required.

Dimensions
In Inches:

EYSR sealing fittings are approved for use in hazardous
locations only when Chico® A sealing compound and
Chico X fiber are used to make the seal.

Standard Materials:
• Body – Feraloy® iron alloy
• Pipe plugs, bolts and set screws – steel
• Gasket – neoprene

148

www.crouse-hinds.com

US: 1-866-764-5454

Cat. #

A

B

C

Cat. #

A

B

C

EYSR2
EYSR3
EYSR4
EYSR5
EYSR6

311/16
43/8
5
51/4
61/4

21/2
31/8
33/8
35/8
4

11/2
31/8
3
3
3

EYSR7
EYSR8
EYSR9
EYSR10

71/2
81/2
913/64
93/4

5
51/2
61/16
65/8

37/8
41/4
43/4
51/4

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

ES Sealing Hubs

Cl. I, Div. 1 & 2, Groups C, D
Explosionproof
Watertight

Chico Sealing Compound and Fiber
see pages 155–156

6F

ES sealing hubs are used to:
• Seal vertical conduit risers at switchgear
and motor control centers, sheet metal
structures or cast boxes and enclosures
• Seal horizontal conduit runs at
enclosures when used with TSC sealing
compound

TSC Epoxy Sealing
Compound

Certifications and
Compliances:
• Class I, Division 1 & 2, Groups C & D
• UL Standard: 1203
• CSA Standard: C22.2 No. 30

Ordering Information

Standard Materials:

Female Male
Hub
Hub
Size Cat. #
Size

Approximate
Internal
Volume
in Cubic
Inches

/2
/4
1
11/4
11/2
2
3
4
5

.65
.65
3.2
4.9
4.7
9.1
36.0
95.0
155.0

• Feraloy® iron alloy

1

Standard Finishes:

3

• Electrogalvanized and aluminum acrylic
paint

Options:
ES sealing hubs, when used with SG
armored gaskets and locknuts, provide a
water and oiltight connection
Description
Suffix
Sealing gaskets and locknuts
SG

1
1
11/2
2
2
21/2
4
5
6

ES31
ES32
ES53
ES64
ES65
ES76
ES108
ES01210
ES014012

A two part epoxy sealing compound may
be used to seal ES sealing hubs. It is
quick and easy to measure, mix and
install. The compound is kneaded until a
uniform color is obtained. It is then
packed around the conductors to
effectively seal the cable.
Std. Ctn. Qty.

Tube Size

Cat. #†

10
10
5

0.5 oz
1.0 oz
4.0 oz

TSC05
TSC1
TSC4

†Order quantity of one (1) TSC05 or TSC1 equals 10
tubes; one (1) TSC4 equals 5 4.0 oz tubes.

Typical Installations

Dimensions
In Inches:

1. ES Sealing Hub
2. EJB Junction Box
3. UNY Union
4. EDS Factory Sealed
Control Station
5. EYS Horizontal Seal
6. Explosion-Proof Motor

www.crouse-hinds.com

1. ES Sealing Hub
2. LT Connector
3. Locknut
4. Sealing Gasket
5. Junction Box
6. UNY Union
7. Synchronous Motor
8. EDS Factory Sealed
Control Station
9. LT Conduit

1. ES Sealing Hub
2. Locknut
3. Sealing Gasket
4. Sheet Metal
Structure, Motor
Control Center,
Panelboard, Unit
Substation, Etc.

Cat. #

a

b

c

d

e

ES31
ES32
ES53
ES64
ES65
ES76
ES108
ES01210
ES014012

19/16
113/16
21/4
23/4
23/4
31/2
51/4
65/8
71/4

/8
7
/8
13/8
13/4
15/8
21/16
35/8
45/8
525/32

2
2
23/4
23/4
31/16
39/16
43/4
63/4
71/4

25/32
25
/32
115/16
115/16
2
2
231/32
427/32
511/32

11/4
11/2
13/4
23/16
27/16
3
41/4
51/4
61/2

US: 1-866-764-5454

7

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

149

6F

Note: Sealing hubs are approved for use in hazardous
locations when Chico® X fiber and Chico A sealing
compound are used to make the seal. Sealing hubs are
approved for horizontal conduit runs for use in
hazardous locations when used with TSC sealing
compound, order 1 oz. tube as TSC1.

Applications:

6F

Ultra High Pressure Seal

Cl. I, Div. 1, Groups B, C, D
Certified to CSA Standards through QPS

6F

Rated to 1500 PSI
Applications:
• If the primary seal in an instrument should fail, the Eaton's CrouseHinds Ultra High Pressure Seal (UHPS) will prevent gases from
migrating through the electrical system into a non-classified
location.
• Are designed to prevent the passage of gases under pressure
through conduits, cables and conductors.
• Are ideal where volatile liquids or gases are stored, processed or
transported under pressure.

Certifications & Compliances:
•
•
•
•
•
•

Class I, Division 1, Groups B, C, D
Certified to CSA Standards through QPS
24 Volt DC - 120 Volt AC
Wire grade is rated to a 600 Volt safety factor
1
/2” MNPT x 1/2” NPT
Conforms to Section 18-108 and 18-158 of the CEC® for The
Requirements of a Secondary Seal.

Standard Materials & Finishes:
• Stainless steel body - natural finish

Quality Assurance:
Each fitting is tested at 1.5 times working pressure (max. working
pressure 1500 PSI) as a gas and liquidtight explosionproof fitting.
Each seal is also di-electric and resistance tested.

Ordering Information:
Catalog Number
CH6DR500X002D14G
CH6DR500X002D16G
CH6DR500X002D18G
CH6DR500X002D22G
CH6DR500X004D14G
CH6DR500X004D16G
CH6DR500X004D18G
CH6DR500X004D22G
CH6DR500X234D14G
CH6DR500X264D16G
CH6DR500X294D16G
CH6DR500X2D2D16G

Description
UHPS, 2 wire,
UHPS, 2 wire,
UHPS, 2 wire,
UHPS, 2 wire,
UHPS, 4 wire,
UHPS, 4 wire,
UHPS, 4 wire,
UHPS, 4 wire,
UHPS, 4 wire,
UHPS, 4 wire,
UHPS, 4 wire,
UHPS, 2 wire,

14 gauge
16 gauge
18 gauge
22 gauge
14 gauge
16 gauge
18 gauge
22 gauge
14G, 2' input,
16G, 2' input,
16G, 2' input,
16G, 2' input,

3' output
6' output
9' output
CF output

INSTALLATION EXAMPLE:

150

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Secondary Process
Seal Assemblies

Cl. I, Div. 1 & 2, Groups B, C, D
Cl. I, Zone 1 & 2 IIB + H2
Cl. II, Div. 1 & 2, Groups E, F, G

6F

NEMA 3, 4, 7BCD, 9

6F

Applications:
Eaton's Crouse-Hinds Secondary Process Seal Assembly with
Rupture Indication Sensor is designed to prevent the passage of
gases under pressure through conduit, cables and conductors while
providing immediate notification of a dangerous, potentially explosive
seal rupture. These assemblies are ideal where volatile liquids or
gases are stored, processed or transported under pressure. If the
primary seal in an instrument should fail, the Eaton's Crouse-Hinds
Secondary Process Seal will prevent gases, vapors and liquids from
migrating into the non-classified location through the electrical
system.

Rupture Indication Sensor:
The Secondary Process Seal features a rupture indication sensor that
opens safely at 60 psi minimum and activates a circuit to a control
system or alarm, which immediately alerts maintenance personnel
that the primary seal has ruptured. The location of the problem can
be pinpointed so the problem can be quickly addressed.
Innovative, intelligent technology combined with easy installation and
low maintenance cost provides a safe and reliable solution for
detection of a process seal rupture within your facility.

Features and Benefits:

Ordering Information:

Secondary Process Seal
• CSA and CSAus certified
• Meets or exceeds ANSI / ISA / CSA / CEC / NEC / API
requirements for a secondary process seal and explosionproof
conduit seal
• Sealed to 1500 psi, operates in any position
• Simplified design allows for easier installation in new and existing
applications
• Integrated packaging contains all necessary components for
installation
• The explosionproof drain allows for the safe release of gas, vapor
or liquid from the electrical system to meet required codes
• Explosionproof terminal box features a simple design to provide
access for quick connection of circuits
• Assembly with drain provides local "make obvious" indication of
primary seal failure

Assembly with
Vent/Drain
2
2
2
2
4
4
4
4

wire,
wire,
wire,
wire,
wire,
wire,
wire,
wire,

14
16
18
22
14
16
18
22

gauge
gauge
gauge
gauge
gauge
gauge
gauge
gauge

SPS214
SPS216
SPS218
SPS222
SPS414
SPS416
SPS418
SPS422

Assembly with
Rupture Indication
Sensor and Vent/Drain
SPS214R
SPS216R
SPS218R
SPS222R
SPS414R
SPS416R
SPS418R
SPS422R

For Process Seal Rupture Indication Sensor replacement, order catalog #PSRIS.

Options:
Description
No terminal blocks
2 terminal blocks
4 terminal blocks

Suffix
(leave option blank)
DIN12
DIN14

Rupture Indication Sensor
• Rupture detection and indication at 60 psi
• Provides remote, immediate notification of a seal rupture, allowing
for maintenance to quickly address the problem and isolate safety
concerns
• Stainless steel construction provides superior corrosion resistance
and durability

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

151

6F

6F

Secondary Process
Seal Assemblies

Cl. I, Div. 1 & 2, Groups B, C, D NEMA 3, 4, 7BCD, 9
Cl. I, Zone 1 & 2 IIB + H2
Cl. II, Div. 1 & 2, Groups E, F, G

Assembly Information
Assembly with process seal rupture indication sensor

*60 psi internal pressure rating at 25°C ambient. Activation pressure may vary +/ - 10% depending on ambient variation.

152

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Secondary Process
Seal Assemblies

6F

NEMA 3, 4, 7BCD, 9

Cl. I, Div. 1 & 2, Groups B, C, D
Cl. I, Zone 1 & 2 IIB + H2
Cl. II, Div. 1 & 2, Groups E, F, G

6F

Installation Examples
Secondary Process Seal with local "make obvious"
indication using an ECD explosionproof drain

Secondary Process Seal with Rupture Indication
Sensor for remote indication, and ECD
explosionproof drain for local "make obvious"
indication

Technical Data - Assembly
Product Certification
The Secondary Process Seal and Assemblies are CSA certified
(Canada, U.S.)

Operating Pressure Rating
Rupture protection to 1500 psi
Rupture indication at 60 psi minimum

Operating Temperature Range
-25ºC to +50ºC
Note: For more extreme temperature and/or pressure requirements, please consult
factory.

Technical Data - Components
Components

Process Seal Rupture
Indication Sensor

Construction

Certifications and Compliances

Rating

Hub - 316
stainless steel

ANSI / ISA 12.27.01 - 2003
CEC 18 - 108, 158
NEC 501.15(F)(3)

–

Switch Assembly - (Div. 1, Zone 1) intrinsically safe
hermetically sealed, (Div. 2, Zone 2) non-incendive
nickeled brass, with Simple apparatus (NEC 504.4)
silicon cable

Ultra High Pressure Seal

Stainless steel

Terminal Housing

Copper-free
aluminum

Drain / Vent

Stainless steel

CSA 22.2 No. 30 - 03
CSA 22.2 No. 14 - 2005
ANSI / ISA 12.27.01 - 2003
CEC 18 - 108, 158
NEC 501.15(F)(3)
UL1203
CSA C22.2 No. 30
UL1203
CSA C22.2 No. 30

www.crouse-hinds.com

US: 1-866-764-5454

Area Suitability

174 mA
24VDC
Cl. I, Div. 1 & 2, Groups
T6 (Tamb ≤ 40°C)
T5 (40°C < Tamb ≤ 55°C) B, C, D
T4 (55°C < Tamb ≤ 80°C) Cl. II, Div. 1 & 2, Groups
E, F, G
Zone 1 IIB+H2 and
24VDC
Zone 2 IIB+H2
120VAC
NEMA 3, 4, 7BCD, 9

–
–

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

153

6F

6F

Secondary Process
Seal Assemblies

Cl. I, Div. 1 & 2, Groups B, C, D
Cl. I, Zone 1 & 2 IIB + H2
Cl. II, Div. 1 & 2, Groups E, F, G

NEMA 3, 4, 7BCD, 9

Dimensions (Inches):

Assembly with rupture sensor and vent/drain
Note:

154

Assembly with vent/drain

Assemblies shown with DIN12 terminal blocks (optional)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

Chico® A and Chico® A-P Sealing Compound
Chico® X Fiber
Chico® SpeedSeal™

6F

For Sealing Fittings and Hubs
Size Ranges:

Chico X fiber:
• Forms a dam between the integral bushing of the sealing fitting and
the end of the conduit and around the electrical conductors entering
the hub
Chico A sealing compound:
• Forms a seal around each electrical conductor and between them
and inside of the sealing fitting to restrict the passage of gases,
vapors or flames through the sealing fitting at atmospheric pressure
and at normal ambient temperatures
Chico® SpeedSeal™ Compound:
• Designed to separate and form an explosionproof seal around each
electrical conductor in Eaton's Crouse-Hinds EYS and EYD sealing
fittings
• Restricts the passage of gases, vapors or flames through the
sealing fitting
• Creates a seal for Class I, Division 1, Groups C, D and Class II,
Division 1, Groups E, F, G hazardous areas

• Chico A compound – 1 lb. to 5 lbs. (provides 23–115 cubic
inches of compound)
• Chico X fiber – 2 oz. to 1 lb.
• Chico A-P (5 pouches per carton) – provides 25 and 55 cubic
inches of compound
• Chico SpeedSeal - 2 oz. or 6 oz. cartridge

6F

Applications:

Eaton's Crouse-Hinds sealing fittings are approved for use in hazardous locations
only when Chico X fiber and Chico A Sealing Compound or Chico SpeedSeal are
used to make the seal.

Ordering Information - Chico A
Net
Weight

Vol.
Cu. In.†

Cat. #

1 lb.
1 lb.‡
5 lb.

23
23
115

Chico A3
Chico A4
Chico A05

Features:
Chico A sealing compound:
• A water soluble powder that can be easily mixed and poured. The
compound, unusually dense, expands slightly when hardening and
bonds to inner walls of sealing fittings. Compound hardens in 60–70
minutes
• Chico A cure time is 8 hours for Class I, Group C and D applications
and 72 hours for Class I, Group A and B applications.
• Chico A has a 1 year shelf life from date of manufacture.
• Chico A ambient temperature range (after curing) is –40°F to +165°F.
Chico A-P Intrapak®:
• Packaged in two-compartment plastic pouch with precise amount of
water for mixing. No mixing or measuring implements required.
• A hard squeeze of the water compartment forces the water into the
compartment containing the Chico compound. Mixing is completed by
kneading the pouch for one minute.
• The mixed sealing compound is poured directly into the sealing fitting
– no funnel required. The package label indicates the size and quantity
of sealing fittings each pouch will properly fill. Compound hardens in
60–70 minutes.
Chico X fiber:
• A mineral wool that packs easily, forming around each conductor
Chico® SpeedSeal™ Compound:
• Installs a reliable seal in five minutes - every time
• Hardens to a dense, strong mass that is suitable for Class I, Division 1,
Groups C, D and Class II, Division 1, Groups E, F, G hazardous
applications.
• UL and cUL Listed for use with 1/ 2" to 2" Eaton's Crouse-Hinds sealing
fittings only.
• Packaged in a 2 oz. or 6 oz. pre-measured cartridge, eliminating the
need for measuring before mixing.
• Packaged with a screw-on nozzle for accurate dispensing.
• Expands four times its original size in the sealing fitting, eliminating the
need to separate the individual conductors with Chico X fiber.
• Chico X fiber dams are not required in horizontal applications,
reducing installation times.
• Completely hardens in 20 minutes, simplifying use for OEMs.
• Suitable for cold temperature environments without the costly need to
build a temporary shelter around sealing fittings. All ice crystals must
be removed from inside the conduit seal before dispensing Chico
SpeedSeal compound. The Chico SpeedSeal compound should be
kept above 10°C (50°F) and below 85°F (29°C) prior to mixing.
The sealing fitting must be kept at or above 4°C (40°F) during the
4 to 10 minute expansion/gel time of the compound.
• 18 months shelf-life.
• Patent pending.
www.crouse-hinds.com

US: 1-866-764-5454

Ordering Information - Chico A-P Intrapak®
Cu. In.
Fill per
Pouch†

No. of
Pouches
per Carton

Cat. #

5
11

5
5

Chico A19 PX*
Chico A39 PX*

*A sixth pouch, containing an appropriate quantity of Chico X fiber, is included in
these cartons.
†Number of cubic inches this amount will fill when set. See internal volume
requirements for EYS, EZS, EYD, EZD and EYSR sealing fittings and ES sealing
hubs (see pages 140–149).
‡Includes 1 oz. Chico X fiber.

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

155

Chico® A and Chico® A-P Sealing Compound
Chico® X Fiber
Chico® SpeedSeal™

6F

6F

For Sealing Fittings and Hubs
Ordering Information Chico X Fiber

Net Weight

Cat. #

2 oz.
8 oz.
1 lb.

Chico X4
Chico X6
Chico X7

Ordering Information - Chico SpeedSeal
Class I, Div. 1, Groups C & D and Class II, Div. 1, Groups E, F and G

Chart for Approximate Amount
of Fiber Per Hub
Hub Size
1
/2
3
/4
1
11/4
11/2
2
21/2
3
31/2
4
5
6

Ozs. Required
/32
/16
/8
1
/4
1
/2
1
11/2
2
3
41/2
7
10
1
1

1

Amount of
SpeedSeal Material
needed per fitting
(in ounces)

Sealing Fitting
Cat. #

1

CHICO SS2
(2 oz. Cartridge)

EYS3, EYS36, EYS31, EYS316
EYD3, EYD36, EYD31, EYD316
EYSX21, EYDX21

2

CHICO SS2
(2 oz. Cartridge)

EYS41, EYS416, EYS4, EYS46
EYD4, EYD46, EYD41, EYD416
EYS51, EYS516, EYS5, EYS56
EYD5, EYD56, EYD51, EYD516
EYSX31, EYDX31
EYSX41, EYDX41

3

CHICO SS6
(6 oz. Cartridge)

EYS61, EYS616, EYS6, EYS66
EYD6, EYD66, EYD61, EYD616
EYSX51, EYDX51

6

CHICO SS6
(6 oz. Cartridge)

MSDS sheets are available at www.crouse-hinds.com

156

www.crouse-hinds.com

US: 1-866-764-5454

SpeedSeal Cat. #

EYS1, EYS16; EYS11, EYS116
EYD1, EYD16, EYD11, EYD116
EYS2, EYS26, EYS21, EYS216
EYD2, EYD26, EYD21, EYD216
EYSX11, EYDX11

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

6F

EYS Tool Kit
For Use with Sealing Fittings and Hubs

6F

Eaton's Crouse-Hinds EYS Tool Kit lets you safely and reliably pack
the fiber dam in explosionproof sealing fittings. Consisting of five
patented, two-sided tools in a handy canvas bag, the EYS Tool Kit
makes the critical steps of separating electrical conductors and
packing fiber dams quick and easy.

Features and Benefits:
• The EYS Tool Kit consists of five tools and a canvas tool bag. Four
tools have two unique ends for a total of 9 different tools.
• Each tool is numbered for easy identification.
• Tools are constructed of durable plastic with smooth and rounded
surfaces that will not abrade the electrical insulation.
• The Hook tool (#3) with a large hook on one end and a small hook
on the other end is designed to lift and separate individual wires.
• The Packing tools (#1, #2 & #4) have rounded ends designed for
packing fiber in between and around electrical conductors.
• The Wedge tools (#2 & #5) are designed for hands-free separation
of conductors while packing fiber.
• The Mirrored tool (#5) allows for easy inspection of the sealing
fittings.
• All tools are sized and precisely angled to accomodate various
sizes of fittings.
• The canvas tool bag is designed to neatly store and protect tools
while not in use.

Ordering Information
Description

Cat. #

EYS Tool Kit

EYS TOOL KIT

The large hook on Tool #3 quickly lifts
all the conductors.

With one of the packing tools, packing
fiber in between and around electrical
conductors is effortless.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

The mirrored tool allows for proper
inspection of the fiber dam in difficult
to see areas.

Copyright© 2013 Eaton’s Crouse-Hinds Business

157

Drains and Breathers

6F

6F

Applications:
• ECD drains and breathers are installed in
enclosures or conduit systems to:
Provide ventilation to minimize condensation
Drain accumulated condensate
• At least one breather should be used with
each drain
• A breather is installed in top of enclosure or
upper section of conduit system
• A "standard" drain is installed in bottom of
enclosure or in lower section of conduit
system
• "Universal" breather or drain functions as a
breather when mounted at the top of an
enclosure, or as a drain when mounted in the
bottom of an enclosure
• "Combination" breather and drain is used in
those applications where the use of a top
mounted breather is not practical due to
limited space; or in offshore and marine
installations where moisture may enter the
enclosure through the breather located on top
of enclosure
• Drains and breathers are installed in hubs or
drilled and tapped openings

• NEC/CEC:

ECD 16, ECD387, ECD-N4D, ECD-N4B –
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

• Thread-in-thread design, suitable for use in
Class I, Division 1 & 2, Groups C,D; Class II,
Division 1, Groups E,F,G; Class II, Division 2,
Groups F,G and Class III areas
• ECD 11, 13 have capability to pass 25 cc of
water per minute and .05 cubic feet of air per
minute at atmospheric pressure
• ECD387 and ECD16 are a unique thread-inshaft design for use in Class I, Division 1 & 2,
Groups B,C,D; Class II, Division 1, Groups
E,F,G; Class II, Division 2, Groups F,G; Class
III areas. The ECD387 and ECD16 can pass
15cc of water per minute. The ECD16 can
pass .01 cubic feet of air per minute.

Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III

158

www.crouse-hinds.com

US: 1-866-764-5454

ECD13

ECD15

ECD16

ECD18, ECD384, ECD15, ECD385 –
Class I, Division 1 & 2, Groups C, D
Class II, Division 1, Groups F, G
Class II, Division 2, Groups F, G
Class III
IP42 IIB (ECD 15 only)

ECD18

ECD284 –

•
•
•
•

Class I, Division 1 & 2, Group C, D
Class II, Division 1, Groups F, G
Class II, Division 2, Groups F, G
UL Standard: 1203
CSA Standard: C22.2 No. 30
Type 4X: ECD-N4D and ECD-N4B
ATEX Certificate # ITS07ATEX15639U

Standard Materials:
• ECD11, ECD15, ECD281, ECD284, ECD384,
ECD385 – stainless steel
• ECD13 – stainless steel with aluminum cap
• ECD16, ECD-N4D, ECD-N4B – stainless steel
• ECD387 – stainless steel
• ECD18 – stainless steel with neoprene tube

Ordering Information
ECD "Type 4X"
Drain and Breather
Size

Drain
Cat. #

Breather
Cat. #

/8
/2

ECD38 N4D
ECD1 N4D

ECD38 N4B
ECD1 N4B

3
1

ECD "Standard"
Drain and Breather
Size

Drain
Cat. #

Breather
Cat. #

/4
/8
/2

ECD281
ECD387
ECD11

ECD13

1
3
1

Size Ranges:
ECD "Universal"

• 1/4" to 1/2"

Breather

Drain or Breather
Size

Cat. #

/4
3
/8
3
/8
1
/2
1
/2

ECD284†
ECD384†
ECD385
ECD15
ECD16

1

†Shorter overall length than ECD15 and ECD385. For
use in confined spaces such as panelboard assemblies.

"Combination" ECD breather and drain:
• Provides ventilation to minimize condensation
and drains accumulated condensate – two
functions performed by a single device
installed in the bottom of an enclosure or
conduit system
• Have the capability to pass 25 cc of water
per minute and .10 cubic feet of air per
minute at atmospheric pressure
• Thread-in-thread and labyrinth design,
suitable for use in Class I, Division 1 & 2,
Groups C and D; Class II, Division 1 & 2,
Groups F and G; and Class III areas

ECD11

IP46 (ECD-N4D and ECD-N4B only)
IIB + Hydrogen (ECD-N4D and
ECD-N4B only)
ECD11, ECD13, ECD281 –

ECD284, ECD384, ECD385 and ECD15
"Universal" drains and breathers have:

"Standard" ECD drains and breathers have:

II 2 G Ex d IIB (ECD15)
II 2 G Ex d IIB + Hydrogen
(ECD Type 4X Series)
Explosionproof
Dust-Ignitionproof

Certifications and
Compliances:

Features:
• Patented labyrinth design, suitable for use in
Class I, Division 1 & 2, Groups C,D and Class
II, Division 1 & 2, Groups F,G areas
• Capability to pass 50 cc of water per minute
and 0.2 cubic feet or air per minute at
atmospheric pressure
• ECD15 and ECD385 each have a well inside
the inner, threaded end to provide for
accumulation of sediment without clogging
when used as a drain

Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Drain
Typical installation of drain and breather in
a combination motor starter
1. At least 5 full threads of drain or breather must be
engaged in matching female thread, taper-tapped in
accordance with NEMA/EEMAC Standard FB-1, Type
NTC or National Bureau of Standards Handbook H28,
Part II, Table 7.6.
2. These breathers and drains can be factory installed on
various explosion-proof equipment. See options on
applicable equipment pages for suffixes to be used.

CAN: 1-800-265-0502

ECD "Combination"
Drain or Breather
Size

Cat. #

/2

ECD18

1

Copyright© 2013 Eaton’s Crouse-Hinds Business

CD Series Ordinary Location Drain

6F

Straight Body • Male Thread
6F

Applications:
CD Series drains are for use in conduit systems to:
• Drain accumulated condensate.
• Provide ventilation to minimize condensation.
Drains are installed in hubs or drilled and tapped openings.

Certifications and Compliances:
• UL Standard 514B

Standard Materials:
• CD bodies and nuts – steel or aluminum
• CD screen – stainless steel

Standard Finishes:
Ordering Information

• Steel – electrogalvanized with chromate treatment.

Options:

Size

Cat. #

/2
3
/4

CD1
CD2

1

Description
Copper-free aluminum construction

Suffix
SA

NEMA 4X Breather/Drain
ATEX and CENELEC Range

Enclosure Type 4X
IP66

I M2 II 2GD, E Exe I & II
(Stainless Steel & Brass only)
II 2GD, E Exe II (Nylon version)
CSA Class I, Division 2, Groups
A, B, C & D, Exe II

Applications:
For use in enclosures to provide a method to effectively drain
moisture while allowing the enclosure to breathe.

Features:
All NEMA 4X breather/drains offer:
• Castellated locknuts that allow moisture to pass between the
enclosure and the locknut to the drain holes in the fitting.
• Available in brass, stainless steel (Type 316) or 30% glass filled nylon.
• Captive "O" ring on recess of the face of the breather/drain to
optimize ingress protection.
Ordering Information
• ATEX and CSA Certified for worldwide market acceptance.
Entry
• Available with metric or NPT threads.
Method
Material
M20
M20
M20
M25
M25
M25
1
/2"
1
/2"
3
/4"
3
/4"

Certifications and Compliances:
• SIRA 99 ATEX 3050U
• I M2 II 2GD, E Exe I & II (Stainless Steel & Brass only)
• II 2GD, E Exe II (Nylon only)
• CSA Class I, Division 2, Groups A, B, C & D, Exe II
• Enclosure Type 4X
• IP66

Brass
Stainless
Nylon
Brass
Stainless
Nylon
Brass
Stainless
Brass
Stainless

Steel
Steel
Steel
Steel

Cat. #
ACDPEB/M20/15
ACDPES/M20/15
ACDPEN/M20/15
ACDPEB/M25/15
ACDPES/M25/15
ACDPEN/M25/15
ACDPEB/050NPT/15
ACDPES/050NPT/15
ACDPEB/075NPT/15
ACDPES/075NPT/15

Operating Temperature:
• –50°C to +85°C

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

159

6F

6F

160

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : mabe
Create Date                     : 2016:10:22 15:06:16+05:30
Modify Date                     : 2016:10:22 15:06:16+05:30
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:01:29 15:25:44-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : mabe
Title                           : f_section.pdf
Document ID                     : uuid:51d711cd-e3d0-4b86-b3d5-dad68add695d
Instance ID                     : uuid:0d9f5000-84fb-4d81-b002-373e23beadbc
Producer                        : Acrobat Distiller 11.0 (Windows)
Page Count                      : 160
EXIF Metadata provided by EXIF.tools

Navigation menu