FXL SF & TRUN 0511 Installation Directions

102663-Installation 102663-Installation 102663-Installation 019813 Batch4 unilog cesco-content

102663-Installationsheet 102663-InstallationSheet 102663-InstallationSheet 019813 Batch4 unilog cesco-content

2016-08-16

: Pdf 144029-Installationsheet 144029-InstallationSheet B3 unilog

Open the PDF directly: View PDF PDF.
Page Count: 4

IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. This product must be installed in accordance with the applicable installation code by a
person familar with the construction and operations of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining xture.
FXL SF & TRUNNION INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our aim is to design the best quality products to get the job done right. We’d
like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com
Slip tter Trunnion
SLIPFITTER MOUNTING
1. The slip tter ts a 2 3/8” O.D. tenon. Place the slip t-
ter over the tenon and secure with the (2) Set Screws
on the side of the slip tter.
2. The angle of the xture can be adjusted.
a. Remove (2) Cover Plate Screws and the Round
Cover Plate.
b. Loosen the Locking Bolt and swivel
the xture.
c. Tighten the Locking Bolt and re-attach Round
Cover Plate.
TRUNNION MOUNTING
Adjust the angle of the xture at the trunnion.
a. Loosen (2) Pivot Bolts and Angle Locking Screw.
b. Swivel the xture.
c. Tighten the Pivot Bolts and Angle Locking Screw.
BEAM SPREAD ADJUSTMENT
WARNING: Make certain power is off.
The lamp socket can be moved from the standard beam
position to the rear position to provide a more narrow
beam or the front for a wider beam.
1. Remove (4) Re ector Screws.
2. Remove the Re ector from the xture.
3. Loosen two socket nuts and slide socket into desired
position.
4. Tighten nuts. Replace Re ector in xture and secure
with (4) Re ector Screws.
Re ector screws (4)
Re ector
Loosen these
2 nuts to
slide socket
FXL SF & TRUNNION INSTALLATION INSTRUCTIONS
ACCESSORIES
Wire Guard mounts with (4) stainless steel screws to
door as shown. Order separately, CAT# GDFXL.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
TROUBLESHOOTING
Check that:
1. Proper lamp is installed. Lamp is not faulty.
2. Fixture is wired properly.
3. Line voltage at the xture is correct.
4. Fixture is grounded properly.
LOCATION
1. Slip tter mounted oodlight can be mounted on a
2 3/8” diameter pipe.
2. Trunnion mounted oodlight can be mounted to a
at surface.
3. Accessories are available for alternate installations.
LAMP INSTALLATION
CAUTION: Prior to installing, check that the lamp is
the correct ANSI type and wattage.
Observe lamp manufacturers recommendations on
lamp operation, ballast type and burn position.
1. Disconnect power. Make sure xture and lamp are
cool enough to touch.
2. Open xture by removing the (4) door screws. Swing
lens door down on hinges.
3. Insert lamp.
4. Before closing lens door make sure frame
gasket is properly seated all around xture.
5. Close door. Tighten (4) screws.
CLEANING
Clean glass lens with nonabrasive glass
cleaning solution.
CAUTION: Be sure xture temperature is cool
enough to touch. Do not clean or maintain while
xture is engerized.
WIRING
All units are factory wired for 277V. If voltages other
than 277V are required, remove the re ector and rewire
for the appropriate voltage.
1. Connect the appropriate BLACK xture lead to the
(+) LINE supply lead.
2. Connect the WHITE xture lead to the (-) COMMON
supply lead.
3. Fixture ground wire must be connected to supply
ground.
4. All unused leads must be capped and insulated.
-*()5
'*9563&
-*/& #-"$,
$0..0/ 8)*5&
(306/% (306/%
REPLACEMENT LAMPS AND
BALLASTS
RAB Lamp ANSI RAB Ballast
Wattage Catalog# Code Catalog#
High Pressure Sodium
250 LHPS250 S50 BHPSH250QT
400 LHPS400 S51 BHPSH400QT
Metal Halide
175 LMH175MOG M57 BMHH175QT
200PS LMH200PS M136 BMHH200PSQ
250 LMH250 M58 BMHH250QT
250PS LMH250PS M153 BMHH250PSQ
320PS LMH320PS M154 BMHH320PSQ
350PS LMH350PS M131 BMHH350PSQ
400 LMH400Z M59 BMHH400QT
400PS LMH400PS M155 BMHH400PSQ
480V Ballasts are available, consult factory.
For 0˚ Up/Down Position
no changes required.
For 30˚ Up/Down Position
Follow 1-2-3
1. Before installing, open the lens frame, loosen the (4)
Re ector Screws and remove the re ector.
2. Remove the Wall Mount Bolts & Lockwashers
which secure the wall mount to the xture.
3. Rotate the wall mount 180˚ and re-attach the Wall
Mount Bolts & Lockwashers. Replace the re ector.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper
grounding is required for safety. This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and operations of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining xture.
FXL WALL MOUNT INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our aim is to design the best quality products to get the job done right.
We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com
WALL MOUNTING OPTIONS
Wall Mount Bolts
& Lockwashers
Top Screws
Stainless
Steel Cable
Wall Feed Conduit Feed
Hardware
(not supplied)
Wall Mounting
Box
MOUNTING TO A WALL
1. Feed supply wires through Wall Mounting Box.
Orient box so that “TOP” is on top.
2. Secure Wall Mounting Box to a sturdy wall. Use
appropriate mounting hardware such as lag bolts
and anchors with washers suitable for the mounting
surface.
3. Bring xture up to the Wall Mounting Box and slide
the stainless steel cable from the xture into the key
hole slot for hands free wiring.
4. Wire the xture using UL approved wire
connectors.
5. Place wired xture over the Wall Mounting Box
and tighten the Top Screws. Now tighten the lower
screws.
6. Apply sealant to all unused conduit entry points.
LOCATION
Wall Mount Only.
FXL WALL MOUNT INSTALLATION INSTRUCTIONS
ACCESSORIES
Wire Guard mounts with (4) stainless steel screws to
door as shown. Order separately, CAT# GDFXL.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
TROUBLESHOOTING
Check that:
1. Proper lamp is installed. Lamp is not faulty.
2. Fixture is wired properly.
3. Line voltage at the xture is correct.
4. Fixture is grounded properly.
LAMP INSTALLATION
CAUTION: Prior to installing, check that the lamp is
the correct ANSI type and wattage.
Observe lamp manufacturers recommendations on lamp
operation, ballast type and burn position.
1. Disconnect power. Make sure xture and lamp are
cool enough to touch.
2. Open xture by removing the (4) door screws. Swing
lens door down on hinges.
3. Insert lamp.
4. Before closing lens door make sure frame gasket is
properly seated all around xture.
5. Close door. Tighten (4) screws.
CLEANING
Clean glass lens with nonabrasive glass cleaning
solution.
CAUTION: Be sure xture temperature is cool
enough to touch. Do not clean or maintain while
xture is energized.
WIRING
All units are factory wired for 277V. If voltages other
than 277V are required, remove the re ector and rewire
for the appropriate voltage.
1. Connect the appropriate BLACK xture lead to the
(+) LINE supply lead.
2. Connect the WHITE xture lead to the (-) COMMON
supply lead.
3. Fixture ground wire must be connected to supply
ground.
4. All unused leads must be capped and insulated.
-*()5
'*9563&
-*/& #-"$,
$0..0/ 8)*5&
(306/% (306/%
BEAM SPREAD ADJUSTMENT
WARNING: Make certain power is off.
The lamp socket can be moved from the standard beam
position to the rear position to provide a more narrow
beam or the front for a wider beam.
1. Remove (4) Re ector Screws.
2. Remove the Re ector from the xture.
3. Loosen two socket nuts and slide socket into desired
position.
4. Tighten nuts. Replace Re ector in xture and secure
with (4) Re ector Screws.
Re ector screws
(4)
Re ector
Loosen these
2 nuts to
slide socket REPLACEMENT LAMPS AND
BALLASTS
RAB Lamp ANSI RAB Ballast
Wattage Catalog# Code Catalog#
High Pressure Sodium
250 LHPS250 S50 BHPSH250QT
400 LHPS400 S51 BHPSH400QT
Metal Halide
175 LMH175MOG M57 BMHH175QT
200PS LMH200PS M136 BMHH200PSQ
250 LMH250 M58 BMHH250QT
250PS LMH250PS M153 BMHH250PSQ
320PS LMH320PS M154 BMHH320PSQ
350PS LMH350PS M131 BMHH350PSQ
400 LMH400Z M59 BMHH400QT
400PS LMH400PS M155 BMHH400PSQ
480V Ballasts are available, consult factory.

Navigation menu