Product Detail Manual

99142-Catalog 99142-Catalog 99142-Catalog 785901 Batch8 unilog cesco-content

2014-10-17

: Pdf 14458-Attachment 14458-Attachment 785901 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 28

1-1
© 2012 Schneider Electric
All Rights Reserved
1LOAD CENTERS
Table of Contents
Section 1
Load Centers
QO Plug-On Circuit Breakers, Page 1-2
QO Load Center, Page 1-5
HOM 1P, Page 1-14
Homeline Load Center, Page 1-15
Combination Service
Entrance Devices, Page 1-19
QO™ Miniature Circuit Breakers 1-2
QO Plug-On Circuit Breakers 1-2
Accessories 1-4
QO Load Centers 1-5
Indoor, 1Ø, Main Lugs 1-5
Indoor, 1Ø Main Circuit Breaker 1-6
Rainproof 1Ø, Main Lugs, Main Circuit Breaker 1-7
3Ø, Main Lugs, Main Circuit Breaker 1-8
Backup Power Solutions and Manual Transfer Accessories 1-9
Special Applications 1-10
QO Load Center Accessories 1-11
Homeline™ Circuit Breakers 1-14
Homeline Load Centers 1-15
Indoor, 1Ø, Main Lugs, Main Circuit Breaker 1-15
Rainproof, 1Ø, Main Lugs, Main Circuit Breakers 1-16
QO and Homeline Load Centers 1-17
Load Center Value Packs 1-11
Load Center Mounted Surge Protection Devices 1-12
QO and Homeline Accessories 1-12
Indoor Load Centers, Dimensions, Knockouts 1-17
Rainproof, Dimensions, Knockouts, Bolt-on Hubs 1-18
Combination Service Entrance Devices (CSED) 1-19
Meter Mains, 100—200 A 1-19
All-In-Ones, 100—225 A 1-20
Meter Mains and All-In-Ones, 300—400 A 1-21
Circuit Breakers, Accessories, Hubs 1-22
Dimensions 1-23
Solar Ready CSED 1-24
Enclosed Devices 1-25
Servicepak™ Power Outlet Panels 1-26
QO™ Load Centers 1-27
QO Plug-on Neutral CAFI Load Centers 1-27
1-2 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers
Class 730, 731, 733 / Refer to Catalog: 0730CT9801
Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-Dswitchboard distribution panels.
Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors.a
The Square D exclusive Qwik-Open mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 A and 20 A QO circuit breakers.
Interupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-12
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
Table 1.1: Plug-On Circuit Breakers Table 1.2: QO/QOB Ring Terminal
(20% $ Price Adder)—Factory-installed only
Amperes
Rating b
1P—120/240 Vac 2P—120/240 Vac
Common Trip
2P—240 Vacc
Common Trip
3P—240 Vac
Common Trip
Ampere Rating Poles Suffix
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
10 k AIR 10–30 A 1, 2, 3 5237
10 A QO110 29.10 QO210 67.00 ——QO310 248.00 35–60 A 1,2 5238
15 A QO115de29.10 QO215d67.00 QO215H 200.00 QO315d248.00 35–50 A 3
20 A QO120de29.10 QO220d67.00 QO220H 200.00 QO320d248.00 70–110 A 2 5273
25 A QO125d29.10 QO225d67.00 QO225H 200.00 QO325d248.00 60–100 A 3
30 A QO130d29.10 QO230d67.00 QO230H 200.00 QO330d248.00
35 A QO135 d29.10 QO235d67.00 ——QO335d248.00 Table 1.3: Wire Sizesb
40 A QO140 d29.10 QO240d67.00 QO240H 200.00 QO340d248.00 Circuit Breaker
Type Ampere Rating Wire Size
(AWG/kcmil)
45 A QO145 d29.10 QO245d67.00 ——QO345d248.00
50 A QO150 d29.10 QO250d67.00 QO250H 200.00 QO350d248.00 QO
1P
10–30 A 14–8 Al/Cu
60 A QO160 d29.10 QO260d67.00 QO260H 200.00 QO360d248.00 10–30 A (2) 14–10 Cu
70 A QO170 d67.00 QO270d134.00 QO270H 224.00 QO370d315.00 35–70 A 8–2 Al/Cu
80 A QO280d189.00 QO280H 315.00 QO380d366.00
QO
2P
10–30 A 14–8 Al/Cu
90 A QO290d189.00 QO290H 315.00 QO390d366.00 10–30 A (2) 14–10 Cu
100 A QO2100d189.00 QO2100H 315.00 QO3100d366.00 35–70 A 8–2 Al/Cu
110 A QO2110d428.00 80–125 A 4–2/0 Al/Cu
125 A QO2125d428.00 150–200 A 4–300 Al/Cu
150 A QO2150dfk 491.00 —— — QO
3P
10–30 A 14–8 Al/Cu, (2) 14-10
Cu
175 A QO2175dfk 491.00 35–70 A 8–2 Al/Cu
200 A QO2200dfk 491.00 80–125 A 4–2/0 Al/Cu
Molded Case Switch 60 A max.–240
Vac ——QO200 70.00 QO300 248.00 QOB-VH 110–150 A 4–300 Al/Cu
Molded Case Switch 100 A max.–240
Vac ——QO2000i200.00 QO3000i366.00 QOT 15–20 A 12–8 Al 14–8 Cu
22 k AIRdQO-AFI, QO-GFI
or QO-EPD
15–30 A 12–8 Al 14–8 Cu
15 A QO115VH e63.00 QO215VHg146.00 ——QO315VHg371.00 40, 50, 60 A 12–4 Al 14–6 Cu
20 A QO120VH e63.00 QO220VHg146.00 ——QO320VHg371.00 QO-PL 10–60 A 12–2 Al 14–2 Cu
25 A QO125VH 73.00 QO225VHg146.00 ——QO325VHg371.00
30 A QO130VH 73.00 QO230VHg146.00 ——QO330VHg371.00 Table 1.4: QOT Tandem Circuit
Breakers
40 A QO140VH 73.00 QO240VHg146.00 ——QO340VHg371.00
50 A QO150VH 73.00 QO250VHg146.00 ——QO350VHg371.00 Ampere RatingbCat. No.d$ Price
60 A QO160VH 73.00 QO260VHg146.00 ——QO360VHg371.00 1P—120/240 Vac
70 A QO170VH 112.00 QO270VHg224.00 ——QO370VHg477.00 15 A and 15 A QOT1515 58.00
80 A QO280VHg315.00 ——QO380VHg530.00 15 A and 20 A QOT1520 58.00
90 A QO290VHg315.00 ——QO390VHg530.00 20 A and 20 A QOT2020 58.00
100 A QO2100VHgh 315.00 ——QO3100VHg530.00 2P—120/240 Vac Common Trip
110 A QO2110VHgh 1034.00 Order two QOT1515 or QOT2020 circuit breakers and
handle tie QOTHT for common switching of center two
poles.
125 A QO2125VHgh 1034.00 —— — —
150 A QO2150VHfgk1061.00 —— — —
175 A QO2175VHfgk1061.00 —— — —
200 A QO2200VHfgk1061.00 —— — —
Table 1.5: Replacement Tandem
Circuit Breakers
For use in Old Style Non-Class CTL
QO Load Centers—10 k AIR
42 k AIRd
40 A QOH240 i317.00 —— — —
45 A QOH245 i317.00 —— — —
50 A QOH250i317.00 —— — —Ampere RatingbCat. No.d$ Price
60 A QOH260i317.00 —— — 1P—120/240 Vac—1 Space Required
70 A QOH270 528.00 15 A and 15 A QO1515 73.00
80 A QOH280 651.00 15 A and 20 A QO1520 73.00
90 A QOH290 651.00 20 A and 20 A QO2020 73.00
100 A QOH2100 651.00 20 A and 30 A QO2030 73.00
110 A QOH2110i1389.00 30 A and 20 A QO3020 73.00
125 A QOH2125 1389.00 —— Two 1P Individual Trip—120/240 Vac—2 Spaces
Required
65 k AIRd15 A and 15 A Order Two QO1515 or QO2020 circuit
breakers and handle tie QOTHT
15 A QH115e117.00 QH215 293.00 ——QH315d507.00 15 A and 20 A
20 A QH120e117.00 QH220 293.00 ——QH320 507.00 20 A and 20 A
25 A QH125i117.00 QH225i293.00 ——QH325i507.00 20 A and 30 A QO20303020j134.00
30 A QH130 117.00 QH230 293.00 ——QH330 507.00 30 A and 20 A
aSee Digest Section 1 for load centers, and Section 9 for panelboards and interiors.
b10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–125 A circuit breakers
are suitable for use with 75oC conductors.
cUL Listed 5 k AIR on corner grounded Delta systems.
dUL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor
group combinations and marked for use with HACR type circuit breakers.
eUL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
fRequires four spaces (1 AWG–300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads.
gUL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, QO-AFI, and QO-PL 10 k AIR circuit breakers
to permit their application at 22 kA fault level.
h100 A maximum branch mounted opposite.
iOrder only. Contact your local Field Office.
jIncludes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT.
kNot suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater.
QOT Tandem
Current limiting QOT
tandem circuit
breakers have a
mounting cam as
shown. Installation
into a QO load
center can only be
made in those
positions having a
mounting pan rail
slot. Meets
Paragraph 408.15 of
the NEC®. UL Listed
as Class CTL
QO 1P
1 Space Required
QOT 1P Tandem
1 Space Required
QO 2P
2 Spaces Required
QO2200 2P 200 A
4 Spaces Required
QO 3P
3 Spaces Required
Pan Rail Slot
Rail Bead
Mounting Cam
DE2A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-3
QO™ Miniature Circuit Breakers QO Plug-On Circuit Breakers
Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801
QO Arc-Fault Circuit Breaker
QO arc-fault circuit breakers provide protection for Series
and Parallel Type Arcing as required by the NEC and local
code adoption, and comply with UL1699.
QO-Dual Function Circuit Breaker
QO Combination Arc Fault and Ground Fault Circuit
Interrupters (Dual Function) provide overload and short
circuit protection, plus arc fault and ground fault protection in
accordance with the NEC, UL1699 and UL943.
QO-GFI
Qwik-Gard circuit breakers provide overload and short circuit
protection, combined with Class A ground fault protection.
Class A denotes a ground fault circuit interrupter that will trip
when a fault current to ground is 6 mA or more, for people
protection. Do not connect to more than 250 feet of load
conductor for the total one-way run to prevent nuisance
tripping.
QO-EPD/EPE
QO-EPD/EPE circuit breakers provide overload and short
circuit protection combined with Class B ground fault protection.
They are designed to provide ground fault protection of
equipment at a 30 mA level (EPD) or 100 mA level (EPE). They
are not designed to protect people from electrical shock.
QO-SWN
Switch Neutral Common Trip 2008 NEC® 514.11
QO-HID
HID circuit breakers are for use on circuits feeding fluorescent
and high intensity discharge (HID) lighting systems such as
mercury vapor, metal halide, or high pressure sodium. These
circuit breakers are physically interchangeable with QO circuit
breakers.
NOTE: QO-K Circuit Breakers are on page 1-27.
QO-HM
High magnetic trip circuit breakers are recommended for
applications where high initial inrush may occur and for
individual dimmer applications.
Non-automatic (Standard) Miniature Switches
Miniature non-automatic switches have the same physical
packaging as miniature circuit breakers, but open only when
the handle is switched to the OFF position.
Non-automatic switches provide no overcurrent protection or
short circuit protection. They must not be used on systems that
have an available fault current greater than the values listed in
the table.
Non-automatic switches are UL Listed per UL 1087 and are
CSA certified.
aUL Listed as HACR type for use with air conditioning, heating and refrigeration
equipment having motor group combinations and marked for use with HACR
type circuit breakers.
bUL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac
fluorescent lighting loads.
c10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors.
35–60 A circuit breakers are suitable for use with 75oC conductors.
dSuitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not
contain load neutral connection.
eSee note in Instruction Bulletin when using in an enclosure with a QO403 or
QON prefix.
fFor 120/240 V only, not for 208Y/120 V.
Interrupting Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-2
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 7-54
Table 1.6: QO Arc Fault Circuit Breakersa
One- Pole
Circuit Breaker Type Ampere
Rating
1P 120 Vac 1P 120 Vac
10 k AIR 22 k AIR
1 Space Required 1 Space Required
Cat. No. $ Price Cat. No. $ Price
Combination Arc-fault
Interrupter
(Pigtail Neutral)
15 QO115CAFI 282.00 QO115VHCAFI 534.00
20 QO120CAFI 282.00 QO120VHCAFI 534.00
Plug-On Neutral
Combination Arc-fault
Interrupter
15 QO115PCAFI 282.00 QO115VHPCAFI 534.00
20 QO120PCAFI 282.00 QO120VHPCAFI 534.00
Two- Pole
Circuit Breaker Type Ampere
Rating
2P 120/240 Vac 2P 120/240 Vac
10 k AIR 22 k AIR
2 Space Required 2 Space Required
Cat. No. $ Price Cat. No. $ Price
Combination Arc-fault
Interrupter
(Pigtail Neutral)
15 QO215CAFIf636.00 QO215VHCAFIf 1068.00
20 QO220CAFIf636.00 QO220VHCAFIf1068.00
Table 1.7: QO-Dual Function Arc Fault Circuit
Breakersa
Circuit Breaker Type Ampere
Rating
1P 120 Vac 1P 120 Vac
10 k AIR 22 k AIR
1 Space Required 1 Space Required
Cat. No. $ Price Cat. No. $ Price
Combination Arc-fault
and Ground Fault
Circuit Interrupter
(Pigtail Neutral)
15 QO115DF 326.00 QO115VHDF 578.00
20 QO120DF 326.00 QO120VHDF 578.00
Plug-On Neutral
Combination Arc-fault
and Ground Fault
Circuit Interrupter
15 QO115PDF 326.00 QO115VHPDF 578.00
20 QO120PDF 326.00 QO120VHPDF 578.00
Table 1.8: QO-GFI Circuit Breakers
Ampere Ratingc
Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter
1P 120 Vac 2P Common Trip
120/240 Vac
3P Common Trip
208Y/120 Vac
10 k AIR 22 k AIR 10 k AIR 10 k AIR
1 Space Required 1 Space Required 2 Spaces Required 3 Spaces
Required
Cat. No. $
Price Cat. No. $
Price Cat. No. $
Price Cat. No. $
Price
15 QO115GFI 233. QO115VHGFI 482. QO215GFI 413. QO315GFI 791.
20 QO120GFI 233. QO120VHGFI 482. QO220GFI 413. QO320GFI 791.
25 QO125GFI 233. QO125VHGFI 482. QO225GFI 413. ——
30 QO130GFI 233. QO130VHGFI 482. QO230GFI 413. QO330GFI 791.
40 QO240GFI 413. QO340GFI 791.
50 QO250GFI 413. QO350GFI 791.
60 QO260GFId413. ——
Table 1.9: QO-EPD Circuit Breakers
Ampere Ratingc
1P
120 Vac
2P Common Trip
120/240 Vac
3P Common Trip
240 Vac
10 k AIR 10 k AIR 10 k AIR
1 Space
Required 2 Spaces Required 3 Spaces Required
Cat. No. $
Price Cat. No. $
Price Cat. No. $
Price Cat. No. $
Price
15 QO115EPD 410. QO215EPD 660. QO315EPDe1077. QO315EPEe1077.
20 QO120EPD 410. QO220EPD 660. QO320EPDe1077. QO320EPEe1077.
25 QO125EPD 410. QO225EPD 660. ————
30 QO130EPD 410. QO230EPD 660. QO330EPDe1077. QO330EPEe1077.
40 QO240EPD 660. QO340EPDe1077. QO340EPEe1077.
50 QO250EPD 660. QO350EPDe1077. QO350EPEe1077.
60 QO260EPDd660. ————
1P
QO-CAFI
1P
QO-DF
1P
QO-GFI
2P
QO-GFI
Table 1.10: QO-SWN Circuit Breakers
Ampere
Ratingc
2 Wire 120 Vac 3 Wire 120/240 Vac
10 k AIR 10 k AIR
2 Spaces Required 3 Spaces Required
Cat. No. $ Price Cat. No. $ Price
10 QO210SWN 95.00 QO310SWN 143.00
15 QO215SWN 95.00 QO315SWN 143.00
20 QO220SWN 95.00 QO320SWN 143.00
25 QO225SWN 95.00 QO325SWN 143.00
30 QO230SWN 95.00 QO330SWN 143.00
40 QO240SWN 95.00 QO340SWN 143.00
50 QO250SWN 95.00 QO350SWN 143.00
Table 1.11: QO-HID Circuit Breakers
Ampere
Ratingc
1P 120/240 Vac 2P Common Trip
120/240 Vac
3P Common Trip
240 Vac
10 k AIR 10 k AIR 10 k AIR
1 Space Required 2 Spaces Required 3 Spaces Required
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
15 QO115HIDb38.10 QO215HID 87.00 QO315HID 300.00
20 QO120HIDb38.10 QO220HID 87.00 QO320HID 300.00
25 QO125HID 38.10 QO225HID 87.00 QO325HID 300.00
30 QO130HID 38.10 QO230HID 87.00 QO330HID 300.00
40 QO140HID 38.10 QO240HID 87.00 ——
50 QO150HID 38.10 QO250HID 87.00 ——
Table 1.12: QO-HM Circuit Breakers
120 Vac—10 k AIR
Ampere
Ratingc
1P
Cat. No $ Price
15 A QO115HMab30.60
20 A QO120HMab30.60
Table 1.13: QO Non-Automatic Miniature Switches,
240 Vac 10 kA
Ampere
Rating
2P 3P
Cat. No. $ Price Cat. No. $ Price
60 QO200 70.00 QO300 248.00
100 QO2000 200.00 QO3000 366.00
Two-wire
QO-SWN
Three-wire
QO-SWN
DE2A Discount
Schedule
1-4 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
QO Miniature Circuit Breakers Accessories
Class 1130 / Refer to Catalog 1100CT0501
Factory-Installed Accessories for use with QO and QOB Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on QO, QO-GFI, QO-EPD, QO-SWN and
QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available
for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will
accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factory-
installed accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers or on QO2150, QO2175, or
QO2200 circuit breakers.
Table 1.14: Accessories for use with QO and QOB Miniature Circuit Breakers
Description Cat. No. $ Price Schedule
Handle Attachments
Handle Tie Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P QO1HT 3.80 DE2E
Converts any two adjacent 120/240 Vac1P side-by-side QOT circuit breakers to independent trip 2P QOTHT 3.80 DE2E
Handle Clamp Clamp for holding QO 1P handle in ON or OFF position QO1LO 3.80 DE2E
Clamp for holding QO or Q1 either 1P, 2P or 3P circuit breaker handles in ON or OFF position HLO1 9.90 DE2E
Handle Padlock Attachment for
Padlocking in ON or OFF position
For padlocking 1P QO circuit breaker in ON or OFF position
Loose attachment QOHPL 9.90 DE2E
Fixed attachment QO1PA 10.70 DE2E
For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position QOTHPA 11.10 DE2E
For padlocking 2P QO-GFI circuit breakers in either ON or OFF position, fixed attachment. GFI2PA 9.20 DE2A
For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position.
Loose attachment QO1HPL 10.70 DE2E
Fixed attachment QO1PL 10.70 DE2E
Handle Padlock Attachment for
Padlocking in OFF position
For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. QO1PAF 43.50 DE2E
For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment. QO2PAF 25.80 DE2E
For padlocking 1P QO-GFI, QO-CAFI, QO-DF and QO-EPD circuit breakers in OFF position only, fixed
attachment. QOGFI1PAF 51.00 DE2E
For padlocking 2P QO-GFI, QO-CAFI and QO-EPD circuit breakers in OFF position only, fixed attachment. QOGFI2PAF 38.40 DE2E
Ring Terminal Ring terminals are available as a factory-installed option. See page 7-10 +20% Price Adder DE2A
Sub-feed Lugs 60 A 2P plug-on – 2 spaces required (6–2 Al/Cu) QO60SL 47.10 DE2A
125 A 2P plug-on – 2 spaces required (12–2/0 Al/Cu) QO2125SL 137.00 DE2A
225 A 2P plug-on – 4 spaces required (4–300 Al/Cu) QO2225SLa308.00 DE2A
125 A 3P plug-on – 3 spaces required (12–2/0 Al/Cu) QO3125SL 137.00 DE3
Mechanical Interlock Attachment For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted
side-by-side so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI 24.90 DE2E
With Retaining Kit
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed
circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO
circuit breakers in QO816L100 load centers.
QO2DTIM 63.00 DE2E
aNot suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater.
QOHPL
QO1PA
QO1PL
QO2DTI
QO1HT
QO1HPL
HLO1
QO1LO
QOTHPA QO2PAF
QO1PAF
QOGFI2PAF
Table 1.15: Factory-Installed Accessories
Accessory Description Rated
Voltage
Coil
Burden
Cat. No.
Suffix
$ Price
Adder Accessory Description Contact
Comb.
Max.
Voltag e
Max.
Load
Cat. No.
Suffix
$ Price
Adder
Shunt Trip
Trips the circuit breaker from a
remote location by means of a trip
coil energized from a separate
circuit. A 120 Vac shunt trip will
operate at 55% or more of rated
voltage. All other shunt trips will
operate at 75% or more of rated
voltage.
Application
For use with momentary or
maintained push button.
Not available on QO-GFI,
QO-EPD.
Shunt trip terminals accept
(2) 0.14– 0.12 AWG Cu.
12 Vac/Vdc
24 Vac/Vdc
60 VA
168 VA -1042 189.00 Auxiliary
Switches
Monitors circuit breaker contact status and
provides a remote signal indicating the circuit
breaker contacts are OPEN or CLOSED.
Application
Auxiliary switch terminals accept
(2) 14–12 AWG Cu leads.
Leads (EH): Yellow for “A’’, Blue for
“B’’, Striped common 18 AWG Cu.
1A
1B
120 Vac
120 Vac
5 A
5 A
-1200
-1201
132.00
132.00
120 Vac
208 Vac
240 Vax
72 VA
228 VA
288 VA
-1021 189.00 Alarm
Switches
Used with control circuits and is actuated only
when the circuit breaker has tripped. Standard
construction includes a normally-open
contact.
Application
Leads: Alarm switch terminals accept
(2) 14–12 AWG Cu leads.
1A 120 Vac 5 A -2100 132.00
DE2 DE2A DE2E DE3 Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-5
QO Load Centers Indoor, 1Ø, Main Lugs
Class 736, 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
1Ø, Field-Installed Main Circuit Breaker Kits
Table 1.16: Main Lugs (Accepts Only QO Plug-On Circuit Breakers.)
Mains
Rating Spaces Max. 1P
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately) Main Wire Size
AWG/kcmil
Equipment Ground Bar
Kit (Order Separately) Box No.
See Page
1-17
Flush
Cat. No.
Surface
Cat. No. $ Price
Cat. No. $ Price Al Cu Cat. No. $ Price
I
N
D
O
O
R
Fixed Mains—Factory-Installed Main Lugs—10 kA Short Circuit Current Ratingb
30 A 2 2 0 41.70 QO2L30Scd 41.70 Cover Included—Without Door 12–10 14–10 PK3GTA1 11.40 1
70 A 2 4 2 69.00 QO24L70F/Sef 69.00 Cover Included—Without Door 12–3 14–4 PK4GTA 10.80 2
100 A
612 6 87.00 QO612L100F/Seg 87.00 Cover Included—Without Door PK7GTA 11.70 4
612 6 90.00 QO612L100DF/Seg 90.00 Cover Included—With Door
8–1
PK7GTA 11.70 4
816 8 131.00 QO816L100F/Seg 131.00 Cover Included—Without Door PK7GTA 11.70 4
816 8 143.00 QO816L100DF/Seg 143.00 Cover Included—With Door
612 6 111.00 QO612L100DFCU/SCUegh 111.00 Cover Included—With Door PK7GTA 11.70 4
816 8 174.00 QO816L100DFCU/SCUegh 174.00 Cover Included—With Door PK7GTA 11.70 4
125 A 4 8 4 93.00 QO148L125GF/Sei 93.00 Cover Included—Without Door 12–2/0 14–2/0 PK7GTAl21
Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Cu Busbj
125 A
12 12 0 196.70 QO112L125G 159.00 QOC16UF QOC16US 37.70
6–2/0
PK9GTAl6
12 24 12 235.70 QO11224L125G 198.00 QOC16UF QOC16US 37.70 PK15GTAl6
16 16 0 255.70 QO116L125G 218.00 QOC24UF QOC24US 37.70 PK12GTAl7
16 24 8 300.70 QO11624L125G 263.00 QOC24UF QOC24US 37.70 PK15GTAl7
20 20 0 271.70 QO120L125G 234.00 QOC24UF QOC24US 37.70 PK15GTAl7
20 24 4 370.70 QO12024L125G 333.00 QOC24UF QOC24US 37.70 PK15GTAl7
24 24 0 381.70 QO124L125G 344.00 QOC24UF QOC24US 37.70 PK15GTAl7
32 32 0 434.60 QO132L125G 395.00 QOC32UF Use Flush 39.60 PK23GTA, LK100ANl8
Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating—Convertible To Main Circuit Breaker—Cu Busbj
150 A
20 30 10 419.00 QO12030L150G 332.00 QOC30UF QOC30US 87.00
6–250
PK23GTA, LK100ANl9
24 24 0 431.00 QO124L150G 344.00 QOC30UF QOC30US 87.00 PK15GTAl9
30 30 0 437.00 QO130L150G 350.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl9
200 A
12 12 0 353.00 QO112L200G 266.00 QOC30UF QOC30US 87.00
6–250
PK15GTAl9
24 36 12 819.00 QO12436L200TFTk732.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl10
30 30 0 494.00 QO130L200G 407.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl9
30 40 10 554.00 QO13040L200G 467.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl9
40 40 0 746.00 QO140L200G 659.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl10
40 60 20 944.00 QO14060L200G 857.00 QOC40UF QOC40US 87.00 (2) PK15GTAl10
42 52 10 921.00 QO14252L200G 810.00 QOC42UF QOC42US 111.00 (2) PK15GTAl11
225 A 42 42 0 828.00 QO142L225G 717.00 QOC42UF QOC42US 111.00 6–300 PK23GTA, LK100ANl11
Fixed Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Ratingbj
400 A
30 30 0 1641.00 QONQ30LS400 (Int) 1080.00 NC50NQVF NC50NQVS 486.00 (1) 1/0–750
or (2) 1/0–300
PK27GTAn
or
PK15GTA6
33.80
53.00
15
MH50 (box)o75.00
42 42 0 1746.00 QONQ42LS400 (Int)m1185.00 NC50NQVF NC50NQVS 486.00 15
MH50 (box) 75.00
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
cWill not accept QO-EPD or Qwik-Gard QO-GFI or QO-AFI circuit breakers.
dMains rated 25 A when Al wire is used.
eOrder F for flush device or S for surface device.
fUse 10 AWG maximum size wire for GFI and AFI circuit breakers.
g70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker.
hCU indicates copper bus.
iCopper bus.
jUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
kSupplied with feed-thru lugs.
lFactory-included.
mInterior only, order box separately.
nPK27GTA includes a 6–2/0 AWG Al/Cu lug.
oPE1A Discount Schedule.
QO120L125G
QO816L100F or S
without cover
Table 1.17: Use with Convertible Main Load Centers Only
QOM1 Frame Size QOM2 Frame Sizes
Main Circuit
Breaker
Ratingp
Convertible
Load Center
Mains Rating
22 k AIRq
Lug Wire Sizer
AWG/kcmil
Main Circuit
Breaker
Ratingp
Convertible
Load Center
Mains Rating
22 k AIRq
Lug Wire Sizer
AWG/kcmil
Main Circuit
Breaker $ Price Main Circuit
Breaker $ Price
50 A 100–125 QOM50VH 140.00
12–2/0 Al or Cu
100 A 150–225 QOM2100VH 468.00
4–300 Al or Cu
60 A 100–125 QOM60VH 140.00 125 A 150–225 QOM2125VH 468.00
70 A 100–125 QOM70VH 140.00 150 A 150–225 QOM2150VH 468.00
80 A 100–125 QOM80VH 201.00 175 A 200–225 QOM2175VH 468.00
90 A 100–125 QOM90VH 201.00 200 A 200–225 QOM2200VH 468.00
100 A 100–125 QOM100VH 201.00 225 A 225 QOM2225VH 468.00
110 A 125 QOM110VH 468.00 ——
125 A 125 QOM125VH 468.00 ——
pDo not exceed the load center mains rating.
q22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems
with up to 22 kA available fault current.
rWire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center
per UL, see pages 1-5 through 1-11 under Main Wire Size.
sAdd suffix 1021 for 120, 208 or 240 Vac shunt trip.
QOM2 Frame Size
100–225 Amperes
QOM1 Frame Size
50–125 Amperes
DE3A PE1A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-6 © 2012 Schneider Electric
All Rights Reserved
QO Load Centers Indoor, 1Ø, Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
1Ø, Field-Installed Main Lugs Kits
Table 1.18: Main Circuit Breaker (Accepts Only QO Plug-On Circuit Breakers.)
Mains
Rating Spaces
Max.
Single
Pole
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately) Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page
1-17
Flush
Cat. No.
Surface
Cat. No. $ Price
Cat. No. $ Price Cat. No. $ Price
I
N
D
O
O
R
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating,
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),b
QOM1 Main Circuit Breaker Frame Size—Copper Bus
100 A
12 12 0 339.70 QO112M100 302.00 QOC12UF QOC12US 37.70
6–1
PK9GTA 13.40 5
16 16 0 379.70 QO116M100 342.00 QOC20U100F QOC20U100S 37.70 PK12GTA 15.80 6
20 20 0 433.70 QO120M100 396.00 QOC20U100F QOC20U100S 37.70 PK15GTA 17.10 6
24 24 0 553.70 QO124M100 516.00 QOC24UF QOC24US 37.70 6–2/0 PK15GTA 17.10 7
32 32 0 726.70 QO132M100 689.00 QOC32UF Use Flush 37.70 PK18GTA 18.80 8
125 A 24 24 0 819.70 QO124M125 782.00 QOC24UF QOC24US 37.70 6–2/0 PK15GTA 17.10 7
32 32 0 1041.60 QO132M125 1002.00 QOC32UF Use Flush 39.60 PK18GTA 18.80 8
Convertible Mains —Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5) b
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150 A
20 30 10 821.00 QO12030M150 734.00 QOC30UF QOC30US 87.00
4–250
PK18GTA 18.80 9
24 24 0 849.00 QO124M150 762.00 QOC30UF QOC30US 87.00 PK15GTA 17.10 9
30 30 0 854.00 QO130M150 767.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9
32 32 0 969.00 QO132M150 882.00 QOC40UF QOC40US 87.00 PK18GTA 18.80 10
200 A
20 40 20 821.00 QO12040M200 734.00 QOC30UF QOC30US 87.00
4–250
PK23GTA 21.30 9
24 24 0 866.00 QO124M200 779.00 QOC30UF QOC30US 87.00 PK15GTA 17.10 9
24 36 12 1287.00 QO12436M200TFTh1200.00 QOC40UF QOC40US 87.00 PK23GTA and
LK100ANg10
30 30 0 879.00 QO130M200 792.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9
30 40 10 957.00 QO13040M200 870.00 QOC30UF QOC30US 87.00 PK23GTA 21.30 9
40 40 0 1121.00 QO140M200 1034.00 QOC40UF QOC40US 87.00 PK23GTA 21.30 10
40 60 20 1431.00 QO14060M200 1344.00 QOC40UF QOC40US 87.00 PK23GTA 21.30 10
42 42 0 1220.00 QO142M200 1109.00 QOC42UF QOC42US 111.00
4–300
PK23GTA 21.30 11
42 52 10 1382.00 QO14252M200 1271.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
225 A 40 40 0 1196.00 QO140M225 1085.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
42 42 0 1253.00 QO142M225 1142.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
Fixed Mains—Factory-installed LAL Main Circuit Breaker, 42 kA Short Circuit Current Ratingc
300 A 42 42 0 4909.00
QONQ42MS300
(int)d4243.00 NC62NQVF NC62NQVS 591.00 (1) 4–500
PK27GTAe
or
PK15GTA6
33.80
53.00
16
MH62 (box)f75.00 or (2) 4–3/0
400 A 42 42 0 4909.00
QONQ42MS400
(int)d4243.00 NC62NQVF NC62NQVS 591.00 (1) 4–500 16
MH62 (box)f75.00 or (2) 4–250
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
cUL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H
circuit breakers only.
dInterior only, order box separately.
ePK27GTA includes a 6–2/0 Al/Cu lug.
fPE1A Discount Schedule.
gFactory included.
hSupplied with feed-thru lugs.
Table 1.19: Use with Convertible Main Load Centers Only
Main Lugs
Ratingi
Use on
Convertible Load Center
with Mains Rating
Cat. No. $ Price
Lug Wire Sizej
AWG/kcmil
Al or Cu
125 A 100–125 A QOL125k 44.10 6–2/0
225 A 150–225 A QOL225k104.00 6–300
iDo not exceed the load center mains rating.
jWire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular
load center per UL, see pages 1-5 through 1-11 under main wire size.
kIf main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from
page 1-13.
QO140M200
QOL125 QOL225
DE3A PE1A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-7
QO Load Centers Rainproof, 1Ø, Main Lugs and Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
Table 1.20: Main Lugs (Accepts Only QO Plug-On Circuit Breakers.)
Mains
Rating Spaces
Max.
Single Pole
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page 1-18
Cat. No. $ Price Al Cu Cat. No. $ Price
R
A
I
N
P
R
O
O
F
Non-Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating
60 A 2 4 2 102.00 QO24L60NRNM 102.00 14–4 14–4 Factory-installed — 1NM
Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating
40 A 2 2 0 113.00 QO2L40RBb113.00 12–6 14–6 PK3GTA1 11.40 1R
70 A 2 4 2 131.00 QO24L70RBb131.00 12–3 14–4 PK4GTA 10.80 1R
100 A
612 6 143.00 QO612L100RBc143.00
8–1
PK7GTA 11.70 2R
612 6 158.00 QO612L100TRBc158.00 Factory-installed — 2R
816 8 231.00 QO816L100RBc231.00 PK7GTA 11.70 2R
612 6 174.00 QO612L100RBCUcd174.00 PK7GTA 11.70 2R
816 8 279.00 QO816L100RBCUcd279.00 PK7GTA 11.70 2R
125 A 4 8 4 152.00 QO148L125GRBd152.00 12–2/0 14–2/0 PK7GTA Factory-included 15R
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
125 A
12 12 0 285.00 QO112L125GRB 285.00
6–2/0
PK9GTA Factory-included 3R
12 24 12 365.00 QO11224L125GRB 365.00 PK15GTA Factory-included 3R
16 24 8 435.00 QO11624L125GRB 435.00 PK15GTA Factory-included 4R
24 24 0 522.00 QO124L125GRB 522.00 PK15GTA Factory-included 4R
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg
QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
150 A 30 30 0 587.00 QO130L150GRB 587.00 4–250 PK23GTA, LK100AN Factory-included 6R
200 A
12 12 0 480.00 QO112L200GRB 480.00
4–250
PK9GTA Factory-included 5R
30 30 0 666.00 QO130L200GRB 666.00 PK23GTA, LK100AN Factory-included 6R
30 40 10 714.00 QO13040L200GRB 714.00 PK23GTA, LK100AN Factory-included 6R
40 40 0 971.00 QO140L200GRB 971.00 PK23GTA, LK100AN Factory-included 7R
40 60 20 1262.00 QO14060L200GRB 1262.00 (2) PK15GTA, (1) LK100AN Factory-included 7R
42 52 10 1194.00 QO14252L200GRB 1194.00 (2) PK15GTA, (1) LK100AN Factory-included 8R
225 A 42 42 0 1310.00 QO142L225GRB 1310.00 4–300 PK23GTA, LK100AN Factory-included 8R
Table 1.21: Main Circuit Breaker (Accepts Only QO Plug-On Circuit Breakers.)
Mains
Rating Spaces
Max.
Single Pole
Circuits a
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page 1-18
Cat. No. $ Price Cat. No. $ Price
R
A
I
N
P
R
O
O
F
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg
QOM1 Main Circuit Breaker Frame Size—Copper Bus
100 A
12 12 0 461.00 QO112M100RB 461.00
6–2/0
PK9GTA 13.40 3R
16 16 0 504.00 QO116M100RB 504.00 PK12GTA 15.80 4R
20 20 0 552.00 QO120M100RB 552.00 PK15GTA 17.10 4R
125 A 24 24 0 954.00 QO124M125RB 954.00 6–2/0 PK15GTA 17.10 4R
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150 A 20 30 10 953.00 QO12030M150RB 953.00 4–250 PK18GTA 18.80 5R
30 30 0 1122.00 QO130M150RB 1122.00 PK18GTA 18.80 6R
200 A
20 40 20 954.00 QO12040M200RB 954.00
4–250
PK23GTA 21.30 5R
30 30 0 1154.00 QO130M200RB 1154.00 PK18GTA 18.80 6R
30 40 10 1179.00 QO13040M200GRB 1179.00 PK23GTA 21.30 6R
40 40 0 1397.00 QO140M200RB 1397.00 PK23GTA 21.30 7R
40 60 20 1815.00 QO14060M200RB 1815.00 PK15GTA 17.10 7R
42 42 0 1469.00 QO142M200RB 1469.00 PK23GTA 21.30 8R
42 52 10 1718.00 QO14252M200RB 1718.00 PK15GTA 17.10 8R
225 A 42 42 0 1631.00 QO142M225RB 1631.00 4–300 PK23GTA 21.30 8R
Convertible Mains—Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5) hg h
QOM1 or QOM2 Main Circuit Breaker Frame Size—Copper Bus
125 A 6 12 6 620.00 QO1612M125FTRBi620.00 4–2/0 PK12GTA 15.80 3R
150 A 8 16 8 863.00 QO1816M150FTRBi863.00 4–250 PK15GTA-L 35.00 6R
200 A 8 16 8 863.00 QO1816M200FTRBi863.00 4–250 PK15GTA-L 35.00 6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUse 10 AWG maximum size wire for AFI and GFI circuit breaker.
c70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
dCopper bus.
eUL short circuit current rating depends on lowest interrupting rating of circuit breakers installed.
fUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
gSide hinge door device; allow 1-1/4 in. on left side for door to open.
h22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22
kA available fault current.
iQO1612M125FTRB provided with QOM1 frame main circuit breaker. QO1816M150FTRB and QO1816M200FTRB provided with QOM2 frame main circuit breaker.
DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-8 © 2012 Schneider Electric
All Rights Reserved
QO Load Centers 3Ø, Main Lugs and Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
3Ø4W—208Y/120 Vac, 3Ø4W—240/120 Vac Delta and 3Ø3W—240 Vac Delta—UL Listed
Table 1.22: Main Lugs and Main Breakers (Accepts Only QO Plug-On Circuit Breakers)
Mains
Rating
Max.
Number
of 1P QO
circuit
breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately)
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Pages
1-17, 1-18
Flush
Cat. No.
Surface
Cat. No. $ Price
Cat. No. $ Price Al Cu Cat. No. $ Pricej
I
N
D
O
O
R
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating a
60 A 3 107.00 QO403L60NF/S 107.00 Cover Included With Load Center (No Door) 10–6 PK4GTA 7.20 13
125 A
12 369.70 QO312L125Gh332.00 QOC16UF QOC16US 37.70i
6–2/0 6–2/0
Factory-incl.g—6
20 508.70 QO320L125Gh471.00 QOC24UF QOC24US 37.70iFactory-incl.g—7
24 577.70 QO324L125Gh540.00 QOC24UF QOC24US 37.70iFactory-incl.g—7
200 A 18 530.00 QO318L200Gh443.00 QOC30UF QOC30US 87.00i6–250 6–250 Factory-incl.f—9
30 707.00 QO330L200Gh620.00 QOC30UF QOC30US 87.00iFactory-incl.f—9
225 A 42 953.00 QO342L225Gh842.00 QOC42UF QOC42US 111.00i6–300 6–300 Factory-incl.f—11
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating b
100 A 27 1058.00 QO327M100c971.00 QOC30UF QOC30US 87.00i4–2/0 4–2/0 PK15GTA 17.10 9
125 A 30 1931.00 QO330MQ125dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12
150 A 30 1931.00 QO330MQ150dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12
42 2119.00 QO342MQ150dh 2027.00 QOC342MQF QOC342MQS 92.00 PK23GTA 21.30 12
200 A 30 1931.00 QO330MQ200dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12
42 2119.00 QO342MQ200dh 2027.00 QOC342MQF QOC342MQS 92.00 PK23GTA 21.30 12
225 A 42 2119.00 QO342MQ225dh 2027.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK23GTA 21.30 12
R
A
I
N
P
R
O
O
F
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratingae
60 A 3 177.00 QO403L60NRB 177.00
Cover Included
—106PK4GTA 10.80 10R
125 A 12 485.00 QO312L125GRB 485.00 6–2/0 6–2/0 Factory Incl.g—3R
20 629.00 QO320L125GRB 629.00 Factory Incl.g—4R
200 A 18 618.00 QO318L200GRB 618.00 6–250 6–250 Factory Incl.f—6R
30 839.00 QO330L200GRB 839.00 Factory Incl.f—6R
225 A 42 1494.00 QO342L225GRB 1494.00 6–300 6–300 Factory Incl.f—8R
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingbe
100 A 27 1185.00 QO327M100RBc1185.00
Cover Included
4–2/0 4–2/0 PK15GTA 17.10 6R
125 A 30 2147.00 QO330MQ125RBd2147.00 4–300 4–300 PK18GTA 18.80 14R
150 A 30 2147.00 QO330MQ150RBd2147.00 4–300 4–300 PK18GTA 18.80 14R
200 A 30 2147.00 QO330MQ200RBd2147.00 4–300 4–300 PK18GTA 18.80 14R
42 2333.00 QO342MQ200RBd2333.00 PK23GTA 21.30 14R
225 A 42 2333.00 QO342MQ225RBd2333.00 4–300 4–300 PK23GTA 21.30 14R
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
aUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b25 kA short circuit current rating SSCR maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10
k AIR branch circuit breakers.
cIncludes factory-installed back fed QO3100VH main circuit breaker.
d65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers.
eSide hinge door device allow 1-1/4 in. on left side for door to open.
fPK23GTA and LK100AN.
gPK15GTA.
hFor Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating
when QODX...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used).
iDE3A Discount Schedule
jDE2 Discount Schedule
Table 1.23: 3Ø, Main Circuit Breakers
Field-installed alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A. Do not exceed the
load center main rating.
Amperage 25 k AIR 65 k AIR 100 k AIRk
70 A QDL32070 QGL32070 QJL32070
80 A QDL32080 QGL32080 QJL32080
90 A QDL32090 QGL32090 QJL32090
100 A QDL32100 QGL32100 QJL32100
110 A QDL32110 QGL32110 QJL32110
125 A QDL32125 QGL32125 QJL32125
150 A QDL32150 QGL32150 QJL32150
175 A QDL32175 QGL32175 QJL32175
200 A QDL32200 QGL32200 QJL32200
225 A QDL32225 QGL32225 QJL32225
$ Price (DE2) 1784.00 2442.00 2796.00
kWhen these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating
is 65 kA at 240 Vac and 100 kA at 208 Vac.
Table 1.24: 3Ø, Main Lugs Kits
Field-installed main lugs for convertible 3Ø main circuit breaker load centers.
Main Lugs
Amperage Rating Cat. No. $ Price Lug Wire Size
AWG/kcmil
125 A QOL3125 67.00 6–2/0 Cu/Al
225 A QOL3225 158.00 6–300 Cu/Al
QO312L125G
QO342MQ200
DE3 DE3A DE2 Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-9
QO Load Centers 1Ø, Backup Power Solutions
Class 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
Table 1.25: Backup Power Solutions (Accept Only QO Plug-On Circuit Breakers.)
Mains
Rating
(A)
Spaces
Max. Single
Pole
Circuits a
Max.
Tandem Circuit
Breakers
Load Center
Box, Interior and Cover
Equipment Grounding Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Box No.
See
Page
1-17, 1-18
Al CuCat. No. $ PriceCat. No. $ Price
Generator Panels—Manual Transfer for Sub-Feed Applications NEMA 1 (Indoor)
I
N
D
O
O
R
Factory-Installed Main Circuit Breakers with Mechanical Interlock—10 kA Short Circuit Current Rating
30 4 8 4QO48M30DSGP 563.00
PK7GTA 11.70
14–8 14–8 4
60 4 8 4QO48M60DSGP 563.00 8–2 8–2 4
Generator Panels—Manual Transfer with Generator Power Inlet Plug for Sub-Feed Applications NEMA 3R (Outdoor)
R
A
I
N
P
R
O
O
F
Factory-Installed Main Circuit Breakers with Mechanical Interlock—10 kA Short Circuit Current Rating
100
48 4 QO1DM10020TRBR 848.00
Factory-Installed
8–2
2R
48 4 QO1DM10030TRBR 848.00 — 2R
48 4 QO1DM10050TRBR 1148.00 — 2R
Generator Panel—Automatic Transfer Switch (Contact your local Square D Field Sales office for more information.) b
I
N
D
O
O
R
Factory- or Field-Installed Main Circuit Breaker—22 kA Short Circuit Current Rating
150 38 42 42 QO13842MX150 1349.00 P K 2 3 G TA 21.30 4–250 4–250 12
200 38 42 42 QO13842MX200 1499.00 P K 2 3 G TA 21.30 4–250 4–250 12
225 38 42 42 QO13842MX225 1649.00 P K 2 3 G TA 21.30 4–250 4–250 12
38 42 42 QO13842UX225 c1199.00 4–250 4–250 12
QOC38MXUF (Cover) 149.00
3R
150 14 28 28 QO11428MX150FTRBde 1349.00 P K 2 3 G TA 21.30 4–250 4–250 7R
200 14 28 28 QO11428MX200FTRBde 1499.00 P K 2 3 G TA 21.30 4–250 4–250 7R
14 28 28 QO11428UX200FTRBcde 1199.00 P K 2 3 G TA 21.30 4–250 4–250 7R
QO Load Center Manual Power Transfer Accessories Cat. No. $ Price Schedule
Manual Transfer Equipment Kit
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that
only one circuit breaker can be “ON’’ at a time. QO2DTI 24.90 DE2E
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual
power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM 63.00 DE2E
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-
up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LA 102.00 DE3A
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-
up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. PK4DTIM4HA 102.00 DE3A
Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up
power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LAL 102.00 DE3A
Generator Circuit Breaker
Interlock Kit
For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P
main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QOCRBGK1 105.00 DE3A
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main
circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QOCGK2 105.00 DE3A
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A)
with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QORBGK2 105.00 DE3A
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bOne main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max.) ordered separately. Automatic
Transfer Switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor.
cUniversal mains – No factory-installed main circuit breaker or main lugs. QOM2 frame size, field-install 22 k AIR. Main circuit breaker or main lugs (see pages 1-5 or 1-6).
dSupplied with feed-thru lugs.
eDevice is rated NEMA 3R and can be used for indoor or outdoor applications.
OFF
ON
OFF
ON
ON
OFF
ON
OFF
135
QO2DTI
PK4DTIM4HA
QO2DTI Installed
QOCGK2 Installed
DE3A Discount
Schedule
1-10 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
QO Load Centers 1Ø, Special Applications
Class 1130 / Refer to Catalog 1100CT0501
1Ø2W—120Vac—1Ø3W—120/240 Vac—UL Listed
Table 1.26: QO Special Application (Accepts Only QO Plug-On Circuit Breakers.)
Mains
Rating
Short
Circuit
Current
Rating
Spaces Max. 1P
Circuits a
Max. Tandem
Circuit
Breakers
Load Center b
Box, Interior, and Cover
Equipment Ground Bar Kit
(Order Separately)
Main Wire Size
AWG/kcmil Box No.
See
Page 1-17
Cat. No. $ Price Cat. No. $ Price Al Cu
I
N
D
O
O
R
Manufactured Housing:
1Ø2W 120 Vac—Main Lugs Only—CSA Certified
30 Ac10 kA 2 2
4
0QO2L30TTSd51.00 Factory-installed 12–10 14–10 1
50 A 10 kA 2 2 QO24L50TTSe78.00 —1462
1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified
30 A 10 kA 3 5 2 QO35FM30TTF/S 83.00 Factory-installed f3
1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified
70 A 10 kA 2 4 2 QO24L70TSe78.00
Factory
Installed
12–3 14–4 2
100 A 10 kA
6 12 6 QO612L100TF/Sg86.00
4–1
4
6 12 6 QO612L100DTF/Sg101.00 4
8 16 8 QO816L100TF/Sg137.00 4
8 16 8 QO816L100DTF/Sg159.00 4
Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package
Convertible Mains—Factory-Installed Main Lugs i—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
125 A
65 kA 12 12
24
20
0QO112L125GC 188.00 PK12GTA Incl. 6–2/0 6
65 kA 12 12 QO11224L125GC 249.00 PK15GTA Incl. 6–2/0 6
65 kA 20 0 QO120L125GC 284.00 PK15GTA Incl. 6–2/0 7
Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
150 A 65 kA 30 30 0 QO130L150TC 452.00 PK23GTA, LK100AN Installed 6–250 9
200 A 65 kA 30 40 10 QO13040L200GC 575.00 PK23GTA, LK100AN Incl. 6–250 9
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
100 A
22 kA 12 12 0 QO112M100C 351.00 PK9GTA 13.40 4–1/0 5
22 kA 12 20 8 QO11220M100C 413.00 PK15GTA 17.10 4–1/0 5
22 kA 16 16 0 QO116M100C 395.00 PK12GTA 15.80 4–1/0 6
22 kA 20 20 0 QO120M100C 446.00 PK15GTA 17.10 4–1/0 6
125 A 22 kA 32 32 0 QO132M125C 1041.00 PK18GTA 18.80 6–2/0 8
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
150 A 22 kA 20 30 10 QO12030M150C 843.00 PK18GTA 18.80 4–250 9
22 kA 30 30 0 QO130M150C 870.00 PK18GTA 18.80 4–250 9
200 A
22 kA 20 40 20 QO12040M200C 843.00 PK23GTA 21.30 4–250 9
22 kA 30 30 0 QO130M200C 896.00 PK18GTA 18.80 4–250 9
22 kA 30 40 10 QO13040M200C 974.00 PK23GTA 21.30 4–250 9
22 kA 40 40 0 QO140M200C 1137.00 PK23GTA 21.30 4–250 10
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bOrder F for flush device or S for surface device.
cMains rating 25 A when Al wire is used.
dWill not accept Qwik-Gard QO-GFI or QO-AFI circuit breaker.
eUse 10 AWG maximum size wire for GFI and AFI circuit breakers.
fMain circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2.
g70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
hUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
iUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
j22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current.
Table 1.27: Service Upgrade Load Centers: 1Ø3W 120/240Vac—UL Listed Load Center with Removable End Walls
Convertible Mains—Factory-Installed Main Breaker—22KA
QOM2 Main Frame Size—Convertible to Main Lugs (See page1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)j
I
N
D
O
O
R
Mains
Rating Spaces Max. 1P
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Extra Long Cover with Door
(Order Separately)
Main Wire Size
AWG / kcmil
Equipment Ground Bar
Kit (Order Separately) Box No.
See Page
1–17
Cat. No. $ Price Flush
Cat. No.
Surface
Cat. No. $ Price Al Cu Cat. No $ Price
200 A 30 40 10 959.00 HOM3040M200CEPk959.00 HOMC30UFL 111.00 4-250 PK23GTA 21.30 10
40 40 0 1,137.00 QO140M200EPm1137.00 QOC40UFL 111.00 PK23GTA 21.30 10
kShips with standard length cover
lBlank Endwall Plates (4) Available Order: EWPLATE $36.00
mCopper Bus, order cover separately QOC40UF/S or QOC40UFL
Table 1.28: Auxiliary Gutter
UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsn. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501
Cat. No. $ Price Cover Conduit Riser Size Width Height Depth
SDAG26 338.00 Flush 1-3/4, 2, 2-1/2 or o3 13.50 26.12 3.75
nOne tap kit required for each riser wire.
oWhen used with B300 bolt-on hubs.
Table 1.29: Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26
Cat. N0. $ Price Use with Auxiliary
Gutter Cat. No.
Riser Wire Tap Off Wire
Lug Type Al/Cu Wire Size Lug Type Al/Cu Wire Size
SDGT30020 81.00 SDAG26 Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6–2/0 AWG
SDGT300300 120.00 SDAG26 Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6 AWG–300 kcmil
SDGT300C10C 49.70 SDAG26 Anderson VCEL030516H1
(Not included) (2) 4 AWG–300 kcmil Anderson VCEL02114S1
(Not Included) (1) 8–1/0 AWG
SDGT300C300C 70.00 SDAG26 Anderson VCEL030516H1
(Not included) (2) 4 AWG–300 kcmil Anderson VCEL030516H1
(Not included) (1) 4 AWG–300 kcmil
QOGL20 Grounding Terminals 40.70 SDAG26 Mechanical (Included) (2) 6–2/0 AWG
DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-11
QO™ and Homeline™ Load Centers and Circuit Breakers 1Ø, Value Packs and Riser Panels
Class 1130, 1170 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
QO Riser Panels
Panelboard-style Covers for Riser Panels
Mono-Flat Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing
solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used
when panel has been converted to a main circuit breaker panel. e
Table 1.30: Value Packs Contains Complete Load Center (Box, Interior and Cover) with Selected Branch Circuit Breaker
Mains
Rating
Spaces
Max.
1P
Circuitsc
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Al/Cu
Box No.
See
Pages
1-17, 1-18
Cat. No. Included Load Center/Circuit Breakers $ Price Cat. No. $ Price
I
N
D
O
O
R
QO (Accepts Only QO Plug-On Circuit Breakers) QO—Copper Bus
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs (See page 1-6) or QOM Main Circuit Breaker (See page 1-5)
100 A 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 839.00 PK18GTA 18.80 4–2/0 8
200 A 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 1103.00 PK23GTA 21.30 4–250 9
30 40 10 QOVP10 (1) QO13040M200C, (10) QO120 1328.00 PK23GTA 21.30 9
Homeline (Accepts Only HOM Plug-On Circuit Breakers)
Convertible Mains—Factory-Installed Main Lugs,
10 kA Short Circuit Current Rating Convertible to appropriate QOM 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-16)
125 A 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 353.00 Included — 6–2/0 6
200 A 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 962.00 Included — 4–250 10
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible appropriate to Main Lugs or Main Circuit Breaker (See page 1-16)
100 A 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 528.00 PK15GTA 17.10 4–2/0 7
20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 528.00 PK15GTA 17.10 7
150 A 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 983.00 PK23GTA 21.30 4–250 10
200 A
20 40 20 HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230 965.00 Included —
4–250
9
30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 1083.00 Included — 10
30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 1083.00 Included — 10
30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 1328.00 Included — 10
30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 1328.00 Included — 10
40 40 0 HOMVP15 (1) HOM40M200C, (10) HOM120 1346.00 PK23GTA 21.30 12
R
A
I
N
P
R
O
O
F
Homeline (Accepts Only HOM Plug-On Circuit Breakers)
Convertible Mains—Factory-Installed Main Circuit Breaker,
22 kA Short Circuit Current Rating Convertible to Main Lugs or Lower Amperage QOM2 Main Circuit Breaker (See page 1-16)
200 A 20 40 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 1253.00 PK23GTA 21.30 4–250 6R
Table 1.31: Offset Interior for Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interiorab
(Accepts Only QO Plug-On Circuit Breakers)
Mains
Rating Spaces
Max.
Single
Pole
Circuitsc
Max.
Tandem
Circuit
Breakers
Load Center Box and Interior Load Center Cover
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Box No.
See
Page 1-17
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Al Cu
I
N
D
O
O
R
Convertible Mains—Factory-Installed Main Lugs,
65 kA Short Circuit Current Rating Convertible to QOM1 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
125 A 12 24 12 QO11224L125WG 338.00 QOC20UFWG 53.00 PK15GTA 17.10 6–2/0 14
20 30 10 QO12030L125WG 465.00 QOC20UFWG 53.00 PK15GTA 17.10 14
Convertible Mains-Factory—Installed Main Lugs,
65 kA Short Circuit Current Rating Convertible to QOM2 22 kA Short Circuit Current Rating Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
200 A 30 40 10 QO13040L200WG 701.00 QOC30UFWG 102.00 PK23GTA 21.30 4–250 23
Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating Convertible to Main Lugs (See page 1-6)
or Lower Amperage QOM2 Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
200 A 24 24 0 QO124M200WG125d683.00 QOC30UFWG 102.00 PK23GTA 21.30 4–250 23
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
bUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
cMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
dComes with 125 A main circuit breaker factory installed.
Mains Rating of Load Center Cat. No. $ Price
125 A NQC20FWG 117.00
200 A NQC30FWG 180.00
eOrder catalog number PK4FL for field-installed lock kit.
DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-12 © 2012 Schneider Electric
All Rights Reserved
Load Center Accessories QO and Homeline Load Center Accessories / Surge Protection
Class 1130 / Refer to Catalog 1100CT0501
Table 1.32: QO Load Center Accessories
Description Cat. No. $ Price Schedule
Retaining Kit for Breakers
Used as Back-fed Mains
Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB,
QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers PK2MB 7.20 DE3A
Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3Ø load centers PK3MB 14.70 DE3A
Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers PK5RK 14.70 DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main
For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02 PK4MB2LA 14.70 DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main
For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02 PK4MB2HA 14.70 DE3A
Cover Sealing Strap Provides means of sealing trim mounting screws on QO load center covers QO1SE 3.60 DE3A
Replacement Cover Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5
Circuit Identification Stickers Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 DE5
QO Load Center Manual Power Transfer Accessories
Manual Transfer Equipment Kit
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that
only one circuit breaker can be “ON’’ at a time. QO2DTI 24.90 DE2E
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual
power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM 63.00 DE2E
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-
up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LA 102.00 DE3A
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-
up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. PK4DTIM4HA 102.00 DE3A
Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up
power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LAL 102.00 DE3A
Generator Circuit Breaker Interlock Kit
For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P
main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker.
Includes a retaining kit.
QOCRBGK1 105.00 DE3A
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main
circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QOCGK2 105.00 DE3A
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225
A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QORBGK2 105.00 DE3A
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that
only one circuit breaker can be “ON’’ at a time. QO2DTI 24.90 DE2E
Table 1.33: Load Center and CSED Surge Protection Devices
Surge Arresters
For use on 1Ø3W, 150 Vac maximum SDSA1175 92.00 DE1B
For use on 3Ø4W, 650 Vac maximum SDSA3650 248.00 DE1B
QO Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum QO2175SB 159.00 DE1B
Homeline Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum HOM2175SB 159.00 DE1B
Surge Arrester Mounting Kit UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker
load centers QOSAMK 11.40 DE3A
PK3MB
QOSAMK
PK2MB
DE1B DE2E DE3A DE5 Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-13
Load Center Accessories QO and Homeline Load Center Accessories
Class 1130, 6610 / Refer to Catalog 1100CT0501
Table 1.34: QO Load Center Accessories
Description Cat. No. $ Price Schedule
Filler Plates
Fills opening in covers if twistout is removed in error QOFP 3.60 DE3A
Fills main circuit breaker opening in convertible load center covers100–125 A QOM1FP 20.30 DE3A
Fills main circuit breaker opening in convertible load center covers150–225 A QOM2FP 20.30 DE3A
Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) KFP 20.30 DE3A
Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Q2FP 20.30 DE3A
Door Lock Kits
Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S,
QO816L100DFCU/SCU, QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP PK8FLa98.00 DE3A
Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains,
3Ø 125–225 A indoor load centers PK6FL 93.00 DE3A
Use with 300 and 400 ampere indoor load centers PK4FL 90.00 PE1A
Neutral / Ground Lugs
Field-installed for 12– 2 Al or 14–4 Cu AWG wire LK70AN 10.10 DE3A
Field-installed for 6–2/0 Al/Cu AWG wire LK100AN 10.80 DE3A
Field-installed for 14–2/0 Al/Cu AWG wire LK125AN 22.10 DE3A
Field-installed for 2–3/0 Al/Cu AWG wire LK150AN 32.40 DE3A
Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S,
150–225 A QO or HOM load center LK225AN 33.20 DE3A
Ground Bar Kits
Standard PK15GTA with a 1–4/0 Al/Cu Lug PK15GTAL 35.00 DE3A
Standard PK18GTA with a 1–4/0 Al/Cu Lug PK18GTAL 37.80 DE3A
Standard PK23GTA with a 1–4/0 Al/Cu Lug PK23GTAL 40.70 DE3A
Insulator Kit for PK7GTA through PK27GTA PKGTAB 43.80 DE3A
Handle Padlock Attachment For padlocking main circuit breakers in convertible load centers OFF 50–125 A QOM1PA 11.00 DE2E
100–225 A QOM2PA 11.00 DE2E
aQO403L60NF/S does not have provisions for a field-installed lock.
PK6FL and PK8FL PK4FL
PKGTAB
QOFP
Table 1.35: Homeline Load Center Accessories
Description Cat. No. $ Price Schedule
Handle Padlock Attachment For padlocking main circuit breakers in convertible load center, “OFF” 50–125 A QOM1PA 11.00 DE2E
100–225 A QOM2PA 11.00 DE2E
Filler Plates
Fills opening in covers if twistout is removed in error HOMFP 3.20 DE3C
Fills main circuit breaker opening in convertible load centers 100–125 A QOM1FP 20.30 DE3A
150–225 A QOM2FP 20.30 DE3A
Neutral Lugs
Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire LK70AN 10.10 DE3B
Field-installed for 6–2/0 AWG Al/Cu wire LK100AN 10.80 DE3B
Field-installed for 14–2/0 AWG Al/Cu wire LK125AN 22.10 DE3B
Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 33.20 DE3A
Retaining Kit for Breakers
Used as Back-fed Mains
Secures circuit breaker to interior when used as a back-fed main.
For HOM612L100F/S, RB and HOM48L125GC, GRB load centers HOM1RK 6.50 DE3C
Secures ONE circuit breaker right side of interior when used as a back-fed main
For 100–125 A convertible main load centers, Series S01 and S02 HOM4RK2LA 14.70 DE3C
Secures ONE circuit breaker right side of interior when used as a back-fed main
For 150–225 A convertible main load centers, Series S01 and S02 HOM4RK2HA 14.70 DE3C
Secures circuit breaker to interior when used as a back-fed main
For 2P 150–200 A circuit breakers HOM5RK 14.70 DE3C
Door Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 93.00 DE3A
Replacement Cover Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5
Circuit Identification Stickers Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 DE5
Generator Circuit
Breaker Interlock Kit
For use on “S” Series NEMA 1 and NEMA 3R load centers. Interlocks a QOM1 2P main
circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker HOMCRBGK1 105.00 DE3D
For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker
of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker HOMCGK2 105.00 DE3D
For use on “S2” and “S3” Series NEMA 3R QOM2 load centers. Interlocks a QOM2 2P main circuit breaker of a
load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker HOMRBGK2 105.00 DE3D
DE2E DE3A DE3B DE3C DE3D DE3E DE5 PE1A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-14 © 2012 Schneider Electric
All Rights Reserved
Homeline™ Circuit Breakers Plug-On Circuit Breakers
Class 1170 / Refer to Catalog 1100CT0501
The Square D Homeline circuit breakers are in a 1 in. wide
format for 1-pole circuit breakers. They are designed to
plug into Homeline load centers.
aUL Listed as SWD (switching duty) rated. Suitable for switching 120
Vac fluorescent lighting loads.
bUL Listed as HACR type for use with air conditioning, heating and
refrigeration equipment having motor group combinations and marked
for use with HACR type circuit breakers.
cRequires four spaces (1 AWG–300 kcmil Al/Cu). Use only in 1Ø panel
rated 150 A or greater.
d15–20 A tandem or quad tandem circuit breakers are suitable for use
with 60oC or 75oC conductors. 25–50 A tandem or quad tandem circuit
breakers are suitable for use with 75oC conductors only.
e15–30 A circuit breakers are suitable for use with 60oC or 75oC
conductors. 40–125 A circuit breakers are suitable for use with 75oC
conductors.
f50–125 A QOM1 frame size; 100–225 A QOM2 frame size.
gDE3C Discount Schedule.
hDE2E Discount Schedule.
iFor 120/240 V only, not for 208Y/120 V.
Table 1.36: HOM
Ampere
Rating AIR 1P—120/240 Vac 2P—120/240 Vac Common Trip
Cat. No. $ Price Cat. No. $ Price
15 A 10 kA HOM115 ab 26.30 HOM215b60.00
20 A 10 kA HOM120 ab 26.30 HOM220b60.00
25 A 10 kA HOM125 b26.30 HOM225b60.00
30 A 10 kA HOM130 b26.30 HOM230b60.00
35 A 10 kA HOM235b60.00
40 A 10 kA HOM140 b26.30 HOM240b60.00
45 A 10 kA HOM245b60.00
50 A 10 kA HOM150 b26.30 HOM250b60.00
60 A 10 kA HOM260b60.00
70 A 10 kA HOM270b123.00
80 A 10 kA HOM280b168.00
90 A 10 kA HOM290b168.00
100 A 10 kA HOM2100b168.00
110 A 10 kA HOM2110b369.00
125 A 10 kA HOM2125b369.00
150 A 10 kA HOM2150BB bc 428.00
175 A 10 kA HOM2175BB bc 428.00
200 A 10 kA HOM2200BB bc 428.00
Table 1.37: HOM-HM
High magnetic trip circuit breakers are recommended for applications
where high initial inrush current may occur.
Amperes 1P—120/240 Vac 2Ps
Cat. No. $ Price
15 A HOM115HMb27.60
20 A HOM120HMb27.60
Table 1.38: HOM-CAFI
Homeline Combination Arc Fault Circuit Interrupters—Provide overload
and short circuit protection, plus arc fault protection in accordance with
the NEC and UL1699.
Circuit Breaker Type Ampere
Rating
Poles
120 Vac Cat. No. $ Price
One-Pole
Combination Arc-Fault
Circuit Interrupter with
Pigtail Neutral
15 A 1 HOM115CAFIb267.00
20 A 1 HOM120CAFIb267.00
Plug-On Neutral
Combination Arc-Fault
Interrupter
15 A 1 HOM115PCAFIb267.00
20 A 1 HOM120PCAFIb267.00
Two-Pole
Combination Arc-Fault
Circuit Interrupter with
Pigtail Neutral
15 A 2 HOM215CAFIbi 595.00
20 A 2 HOM220CAFIbi 595.00
Table 1.39: HOM-DF
Homeline Combination Arc Fault and Ground Fault Circuit Interrupters
(Dual Function)—Provide overload and short circuit protection, plus arc
fault and ground fault protection in a single device in accordance with
the NEC, UL1699 and UL943.
Circuit Breaker Type Ampere
Rating
Poles
120 Vac Cat. No. $ Price
Combination Arc-Fault and
Ground Fault Circuit Interrupter
with Pigtail Neutral
15 A 1 HOM115DFb312.00
20 A 1 HOM120DFb312.00
Plug-On Neutral Combination
Arc-Fault and Ground Fault
Circuit Interrupter
15 A 1 HOM115PDFb312.00
20 A 1 HOM120PDFb312.00
Table 1.40: HOM-GFI
HOM-GFI circuit breakers provide overload and short circuit protection,
combined with Class A ground fault protection. Class A denotes a
ground fault circuit interrupter that will trip when a fault current to
ground is 6 milliamperes or more.
Ampere
Rating AIR
1P—120 Vac 2P—120/240 Vac
Common Trip
1 Space Required 2 Spaces Required
Cat. No. $ Price Cat. No. $ Price
15 A 10 kA HOM115GFI 212.00 HOM215GFI 413.00
20 A 10 kA HOM120GFI 212.00 HOM220GFI 413.00
30 A 10 kA HOM230GFI 413.00
40 A 10 kA HOM240GFI 413.00
50 A 10 kA HOM250GFI 413.00
Table 1.41: HOM-EPD—10 k AIR
Homeline Equipment Protection Device—Circuit Breakers with 30 mA
Equipment Ground Fault Protection (UL Listed)
Amperes 1P—120 Vac 2P—120/240 Vac
Common Trip
Cat. No. $ Price Cat. No. $ Price
15 A HOM115EPD 374.00 HOM215EPD 660.00
20 A HOM120EPD 374.00 HOM220EPD 660.00
25 A HOM225EPD 660.00
30 A HOM230EPD 660.00
40 A HOM240EPD 660.00
50 A HOM250EPD 660.00
HOM 1P
1 Space Required
HOM 2P
2 Spaces Required
HOM 2P GFI
(With Ground Fault
Circuit Interrupter)
2 Spaces Required
HOM 1P GFI
(With Ground Fault
Circuit Interrupter)
1 Space Required
HOM 1P CAFI
HOMT Quad
Circuit Breaker
2 Spaces Required
HOM2200BB
Branch Circuit Breaker
4 Spaces Required
HOM 1P DF
Table 1.42: HOMT Tandem Circuit Breakers
Ampere RatingdAIR
1P Tandem—120/240 Vac (One Space
Required)
Cat. No. $ Price
15 and 15 A 10 kA HOMT1515b52.00
15 and 20 A 10 kA HOMT1520b52.00
20 and 20 A 10 kA HOMT2020b52.00
30 and 15 A 10 kA HOMT3015b52.00
30 and 20 A 10 kA HOMT3020b52.00
Table 1.43: HOMT Quad Tandem Circuit Breakers
Ampere Rating d
AIR
2P Tandem—120/240 Vac (Two Spaces
Required)
1P 2P Cat. No. $ Price
(2) 15 A 15 A 10 kA HOMT1515215 b120.00
(2) 15 A 20 A 10 kA HOMT1515220 b120.00
(2) 15 A 25 A 10 kA HOMT1515225 b120.00
(2) 15 A 30 A 10 kA HOMT1515230 b120.00
(2) 15 A 40 A 10 kA HOMT1515240 b120.00
(2) 15 A 50 A 10 kA HOMT1515250 b120.00
(2) 20 A 20 A 10 kA HOMT2020220 b120.00
(2) 20 A 25 A 10 kA HOMT2020225 b120.00
(2) 20 A 30 A 10 kA HOMT2020230 b120.00
(2) 20 A 40 A 10 kA HOMT2020240 b120.00
(2) 20 A 50 A 10 kA HOMT2020250 b120.00
Note: Typical catalog number (e.g. HOMT 1515230) represents two 1P, outer
poles (two 15 A 1P CBs) and one 2P inner circuit breaker with common
trip (one 30 A 2P CB).
Table 1.44: Circuit Breaker Wire Sizese
Breaker Type Ampere
Rating
Wire Size (AWG/kcmil)
Aluminum Copper
HOM
1P
15–30 A 14–8 AWG 14–8 AWG or
(2) 14–10 AWG
40–50 A 8–2 AWG 8–2 AWG
HOM
2P
15–30 A 14–8 AWG 14–8 AWG or
(2) 14–10 AWG
35–70 A 8–2 AWG 8–2 AWG
80–125 A 4–2/0 AWG 4–2/0 AWG
150–200 A 4 AWG–300 kcmil 4 AWG–300 kcmil
HOMT and Quad 15–30 A 14–8 AWG 14–8 AWG
Quad Only 40–50 A 6–12 AWG 6–14 AWG
HOM-GFI - 1P 15–20 A 14–10 AWG 14–10 AWG
HOM-GFI - 2P 15–50 A 12–4 AWG 14–6 AWG
Table 1.45: Accessories
Description Cat. No. $ Price
Handle Attachments
Handle Tie: Converts any two adjacent 120/240 Vac
single HOM circuit breakers to independent trip 2P HOM1HTg3.50
Handle Tie: Converts any two adjacent 120/240 Vac
1P side-by-side HOMT circuit breakers to
independent trip 2P
HOMTHTg3.80
Handle Clamp: Clamp for holding HOM 1P handle in
the ON or OFF position QO1LOh3.80
Handle Blocking Device: Attaches to standard HOM
2P circuit breakers for holding the handle in the OFF
position
HOM2HBDg10.70
Handle Padlock Attachment: For padlocking 1P
Standard HOM breakers in the ON or OFF position HOM1PAg9.90
Handle Padlock Attachment: For
padlocking 2P Standard HOM circuit
breakers in ON or OFF position
15–70 A HOM2PALAg9.90
80–125 A HOM2PAHAg9.90
150–200 A HOM2PAVHAg50.00
Handle Padlock Attachment: For padlocking 1P CAFI,
DF, GFI, and EPD HOM breakers in ON or OFF
position
HOMELEC1PA 9.90
Handle Padlock Attachment: For padlocking 2P CAFI,
GFI, and EPD HOM breakers in ON or OFF position HOMELEC2PALA 9.90
Handle Padlock Attachment: For padlocking center
poles of Homeline Quad breakers in the OFF position HOMQPA 9.90
Handle Padlock Attachment: For
padlocking main circuit breakers in
convertible load center in OFF position
50–125 A QOM1PAfh 11.00
100–225 A QOM2PAfh 11.00
Sub-Feed Lugs
125 A 2P plug-on—2 spaces required HOML2125 47.60
225 A 2P plug-on—4 spaces required HOML2225c296.00
HOMT 1P
1 Space Required
DE3D DE3C DE2E Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-15
Homeline Load Centers Indoor, 1Ø, Main Lugs and Main Circuit Breaker
Class 1170 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
Table 1.46: Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers.)
Mains
Rating Spaces
Max.
Single
Pole
Circuits a
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover b
Main Wire Size
AWG/kcmil
Equipment Ground Bar Kit
(Order Separately) Box No.
See
Page 1-17
Cat. No. $ Price
(DE3C) Al Cu Cat. No. $ Price
(DE3A)
I
N
D
O
O
R
Main Lugs—10 kA Short Circuit Current Rating Order HOM Circuit Breakers (See page 1-14)
Factory-installed Fixed Main Lugs
70 A 2 4 2 HOM24L70F/Sdc 59.00 12–3 14–4 PK3GTA1 11.40 2
100 A 6 12 6 HOM612L100F/Sce 78.00 8–1 PK7GTA 11.70 4
125 A 4 8 4 HOM48L125GC 86.00 12–2/0 14–2/0 PK7GTA Factory-included 21
Convertible Mains—Factory-installed Main Lugs
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16)
125 A
816 8 HOM816L125C 132.00
6–2/0
PK15GTA 17.10 6
816 8 HOM816L125TC 150.00 Factory-installed — 6
12 12 0 HOM12L125C 174.00 PK15GTA 17.10 6
12 24 12 HOM1224L125TC 204.00 Factory-installed — 6
16 24 8 HOM1624L125C 260.00 PK15GTA 17.10 8
20 20 0 HOM20L125C 237.00 PK15GTA 17.10 8
20 24 4 HOM2024L125TC 288.00 Factory-installed — 8
24 24 0 HOM24L125TC 344.00 Factory-installed — 8
Convertible Mains—Factory-installed Main Lugs
QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-16)
150 A 30 30 0 HOM30L150C 375.00 4–250 PK23GTA 21.30 10
30 30 0 HOM30L150TC 396.00 4–250 Factory-installed — 10
200 A
16 32 16 HOM1632L200TC 357.00
4–250 Factory-installed —
9
16 32 16 HOM1632L200TCFTf575.00 10
20 40 20 HOM2040L200TC 417.00 9
200 A
30 30 0 HOM30L200C 420.00
4–250
PK23GTA 21.30 10
30 30 0 HOM30L200TC 464.00 Factory-installed — 10
30 40 10 HOM3040L200TC 479.00 Factory-installed — 10
40 40 0 HOM40L200C 618.00 PK23GTA 21.30 12
40 40 0 HOM40L200TC 671.00 Factory-installed — 12
40 60 20 HOM4060L200TC 839.00 Factory-installed — 12
42 52 10 HOM4252L200TC 804.00 Factory-installed — 12
225 A 42 42 0 HOM42L225C 732.00 6–250 PK23GTA 21.30 12
Main Circuit Breaker—22 kA Short Circuit Current Rating
Convertible Mains—Factory-installed Main Circuit Breaker
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
100 A
816 8 HOM816M100C 315.00 6–1 PK15GTA 17.10 5
816 8HOM816M100TC 333.00 6–1 Factory-installed — 5
12 12 0 HOM12M100C 294.00 6–2/0 PK15GTA 17.10 6
12 24 12 HOM1224M100TC 384.00 6–2/0 Factory-installed — 6
20 20 0 HOM20M100C 396.00 6–1 PK15GTA 17.10 7
24 24 0 HOM24M100C 513.00 6–2/0 PK15GTA 17.10 8
30 30 0 HOM30M100C 672.00 6–2/0 PK23GTA 21.30 10
125 A
12 24 12 HOM1224M125C 606.00
6–2/0
PK15GTA 17.10 6
12 24 12 HOM1224M125TC 620.00 Factory-installed — 6
24 24 0 HOM24M125C 710.00 PK15GTA 17.10 8
30 30 0 HOM30M125C 812.00 PK23GTA 21.30 10
Convertible Mains—Factory-installed Main Circuit Breaker
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
150 A
16 32 16 HOM1632M150TC 636.00
4–250
Factory-installed — 9
20 30 10 HOM2030M150TC 750.00 Factory-installed — 9
30 30 0 HOM30M150C 776.00 PK23GTA 21.30 10
200 A
12 24 12 HOM1224M200TC 572.00
4–250
Factory-installed — 9
16 32 16 HOM1632M200TC 675.00 Factory-installed — 9
20 40 20 HOM2040M200C 711.00 PK23GTA 21.30 9
20 40 20 HOM2040M200TC 764.00 Factory-installed — 9
30 30 0 HOM30M200C 798.00 PK23GTA 21.30 10
30 40 10 HOM3040M200TC 891.00 Factory-installed — 10
40 40 0 HOM40M200C 1019.00 PK23GTA 21.30 12
40 60 20 HOM4060M200C 1367.00 PK23GTA 21.30 12
42 42 0 HOM42M200C 1094.00 PK23GTA 21.30 12
42 52 10 HOM4252M200C 1313.00 PK23GTA 21.30 12
225 A 42 42 0 HOM42M225C 1116.00 4–250 PK23GTA 21.30 12
Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs
QOM2 Main Frame Size—Field-install Main Circuit Breaker or Main Lugs (See page 1-16)
200 A
16 32 16 HOM1632U200TC 293.00
4–250
Factory-installed — 9
20 40 20 HOM2040U200TC 357.00 Factory-installed — 9
30 40 10 HOM3040U200TC 530.00 Factory-installed — 10
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
bC at end of catalog number indicates combination flush/surface cover included with device.
cF/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
dHOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
e70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
fSupplied with feed-thru lugs.
DE3A DE3C Discount
Schedule
1-16 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
Homeline™ Load
Centers
Rainproof, 1Ø, Main Lugs and Main Circuit Breakers
Class 1170 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
1Ø, Field-Installed Mains Kits
Table 1.47: Convertible Main Load Centers (Accepts Only HOM Plug-On Circuit Breakers.)
Mains Rating Spaces
Max. Single
Pole
Circuits a
Max. Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover
Main Wire Size
AWG/kcmil
Equipment Ground Bar Kit
(Order Separately) Box No.
See
Page 1-18
Cat. No. (DE3C) $ Price Al Cu Cat. No. (DE3A) $ Price
Main Lugs—10 kA Short Circuit Current Rating
Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating
R
A
I
N
P
R
O
O
F
70 A 2 4 2 HOM24L70RBb111.00 12–3 14–4 PK4GTA 10.80 1R
100 A 6 12 6 HOM612L100RBf129.00 8–1 PK7GTA 11.70 2R
125 A 4 8 4 HOM48L125GRB 137.00 12–2/0 14–2/0 PK7GTA Factory-included 15R
Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See Below)
125 A
816 8 HOM816L125RB 248.00
6–2/0
PK15GTA 17.10 3R
12 12 0 HOM12L125RB 234.00 PK15GTA 17.10 3R
12 24 12 HOM1224L125RB 278.00 PK15GTA 17.10 3R
20 20 0 HOM20L125RB 383.00 PK15GTA 17.10 4R
Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See Below)
200 A
12 12 0 HOM12L200RB 423.00
4–250
PK23GTA 21.30 5R
20 40 20 HOM2040L200RB 560.00 PK23GTA 21.30 6R
30 30 0 HOM30L200RB 587.00 PK23GTA 21.30 7R
30 40 10 HOM3040L200RB 759.00 ——
40 40 0 HOM40L200RB 911.00 PK23GTA 21.30 14R
40 60 20 HOM4060L200RB 1139.00 PK23GTA 21.30 14R
42 52 10 HOM4252L200RB 1092.00 PK23GTA 21.30 14R
Main Circuit Breaker—22 kA Short Circuit Current Rating
Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d
R
A
I
N
P
R
O
O
F
100 A
816 8 HOM816M100RB 429.00 6–1 PK15GTA 17.10 3R
12 12 0 HOM12M100RB 416.00
6–2/0
PK15GTA 17.10 3R
20 20 0 HOM20M100RB 531.00 PK15GTA 17.10 4R
24 24 0 HOM24M100RB 606.00 PK15GTA 17.10 6R
125 A 816 8 HOM816M125RB 716.00 6–2/0 PK15GTA 17.10 3R
24 24 0 HOM24M125RB 858.00 PK15GTA 17.10 6R
Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
150 A 30 30 0 HOM30M150RB 978.00 4–250 PK23GTA 21.30 7R
200 A
20 40 20 HOM2040M200RB 872.00
4–250
PK23GTA 21.30 6R
30 30 0 HOM30M200RB 1004.00 PK23GTA 21.30 7R
30 40 10 HOM3040M200RB 1152.00 PK23GTA 21.30 7R
40 40 0 HOM40M200RB 1277.00 PK23GTA 21.30 14R
40 60 20 HOM4060M200RB 1596.00 PK23GTA 14.20 14R
42 52 10 HOM4252M200RB 1532.00 PK23GTA 14.20 14R
225 A 16 24 8 HOM1624M225RB 1182.00 4–250 PK15GTA 17.10 7R
42 42 0 HOM42M225RB 1323.00 PK23GTA 21.30 14R
Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs,
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) c
150 A 8 16 8 HOM816M150FTRB 785.00 4–250 PK15GTAL 35.00 6R
200 Ae816 8 HOM816M200FTRB 785.00 4–250 PK15GTAL 35.00 6R
Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker or Main Lugs c
QOM2 Main Frame Size—Field-install Main Circuit Breaker or Main Lugs (See Kits Below)
200 A 8 16 8 HOM816U200FTRB 446.00 4–250 PK15GTAL 35.00 6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
bHOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
cSide hinge door device allow 1-1/4 in. on left side for door to open.
d22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
eRated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire.
f70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
Table 1.48: For Convertible Load Centers Only
Field-Installed
Main Type Frame Size Main g
Ampere Rating
Use on Convertible Load
Center with Mains Rating Cat. No. $ Price
(DE3A)
Lug Wire Size j
AWG/kcmil
Main Lugs h125 A 100–125 A QOL125 44.10 6–2/0 Al or Cu
225 A 150–225 A QOL225 104.00 6–300 Al or Cu
Main Circuit
Breaker i
QOM1
50 A 100–125 A QOM50VH 140.00
12–2/0 Al or Cu
60 A 100–125 A QOM60VH 140.00
70 A 100–125 A QOM70VH 140.00
80 A 100–125 A QOM80VH 201.00
90 A 100–125 A QOM90VH 201.00
100 A 100–125 A QOM100VH 201.00
110 A 125 A QOM110VH 468.00
125 A 125 A QOM125VH 468.00
QOM2k
100 A 150–225 A QOM2100VH 468.00
4–300 Al or Cu
125 A 150–225 A QOM2125VH 468.00
150 A 150–225 A QOM2150VH 468.00
175 A 200–225 A QOM2175VH 468.00
200 A 200–225 A QOM2200VH 468.00
225 A 225 A QOM2225VH 468.00
gDo not exceed the load center mains rating.
hIf main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13.
i22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with
up to 22 kA available fault current.
jWire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see
pages 1-5 through 1-11 under Main Wire Size.
kAdd suffix 1021 for 120, 208, 240 Vac shunt trip.
QOL225
Main Lug Kit
QOL125
DE3A DE3C Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-17
QO™ and Homeline™ Load Centers Indoor, Dimensions and Knockouts
Class 1130, 1170 / Refer to Catalog 1100CT0501
Indoor Knockout Information and Enclosure Dimensions
Table 1.49: Enclosure Dimensions
Dimensions Dimensions
Box
No.
W H D Box
No.
W H D
in. mm in. mm in. mm in. mm in. mm in. mm
1 3.81 97 6.72 171 3.00 76 13 5.88 149 13.12 333 3.38 86
2 4.81 122 9.30 236 3.19 81 14 14.25 362 20.92 531 3.75 95
3 4.81 122 9.30 236 3.19 81 15 20.00 508 50.00 1270 5.75 146
4 8.88 226 12.57 319 3.80 97 16 20.00 508 62.00 1727 5.75 146
5 14.25 362 14.92 379 3.75 95 17 20.00 508 53.00 1346 5.75 146
6 14.25 362 17.92 455 3.75 95 18 5.88 149 16.12 409 3.38 86
7 14.25 362 20.92 531 3.75 95 19 7.56 192 23.12 587 4.25 108
8 14.25 362 26.04 661 3.75 95 20 9.62 244 26.12 663 4.75 121
9 14.25 362 29.86 758 3.75 95 21 8.88 226 14.80 376 3.80 97
10 14.25 362 33.78 858 3.75 95 22 8.55 217 23.92 608 3.95 100
11 14.25 362 37.98 965 3.75 95 23 14.25 362 29.86 758 3.75 95
12 14.25 362 39.37 1000 3.75 95
Table 1.50: Knockout Information
Knockouts
Symbol A B C D E F G H I
Conduit
Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2
Box 1
A,B,C
A
A
A,B,C
A
A,B,C,D
A,B,C
A
A,B,C
A
A
Box 3
A,B
B,C,D,E
B,C,D,E
A
A,B
A
Box 4
B,C,D,E
B,C,D,E
B,C,D,E
B,C,D,E
Box 5
A
B,C,D,E C,D,E,F,G A,B
B,C,D,E
A,B,C,D
A,B
A
C,D,E,F
A,B
A
C,D,E,F
B,C,D,E
A,B,C,D
B,C,D,E A
C,D,E,F,G
A,B
B,C,D,E A
C,D,E,F,G
A,B
A,B
A
C,D,E,F
Box 7
B,C,D,E
A,B,C,D
B,C,D,E A
C,D,E,F,G
A,B
A,B,C,D
B,C,D,E
C,D,E,F
B,C,D,E
D,E,F,G
B,C,D,E A
C,D,E,F,G A,B
A,B
B,C
A
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
D,E,F,G
Box 9
B,C,D,E A
C,D,E,F,G
A,B
D,E,F,G
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
B,C,D,E
D,E,F,G
A,B
B,C
A
Box 10
B,C,D,E A
C,D,E,F,G
A,B
D,E,F,G
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
B,C,D,E
D,E,F,G
Box 11
A,B
B,C
A
B,C,D,E A
C,D,E,F,G
A,B
C,D,E,F
D,E,F,G
C,D,E,F
B,C,D,E
A,B,C,D
B,C,D,E
D,E,F,G
A,B
B,C
A
Box 13
A,B,C,D
C,D,E,F
C,D,E,F
Box 14
A,B
A
B,C,D,E
B,C,D,E
A,B,C,D
A,B,C
AA,B
D,E,F,G
A,B
C,D,E,F
D,E,F,G,H,I
D,E,F,G,H
A,B,C,D
C,D,E,F
Box 19
D,E,F,G
C,D,E,F
D,E,F,G
E,F,G,H
B,C,D,E
B,C,D,E
A
A,B
A
B,C,D,E
B,C,D,E
B,C,D,E
B,C,D,E
A,B
C,D,E,F
B,C,D,E
D,E,F,G
A,B
B,C
A
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
D,E,F,G
A,B,C
AA,B
D,E,F,G
www.schneider-electric.us
1LOAD CENTERS
1-18 © 2012 Schneider Electric
All Rights Reserved
QO™ and Homeline™ Load Centers Rainproof, Dimensions, Knockouts and Bolt-on Hubs
Class 1130, 1170 / Refer to Catalog 1100CT0501
Bolt-On Hubs
Square D equipment with “R’’ or “RB’’ suffix, designated NEMA 3R rainproof construction,
utilizes bolt-on hubs listed below. “RB’’ devices will accept 3/4 in. through 2-1/2 in. bolt-on
hubs without the use of reducers. Off-center conduit thread openings and elongated
mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and
bends. Catalog suffix “R’’ devices require 3 in. through 4 in. field cut opening. Hubs are
suitable for use with conduit having ANSI standard taper pipe thread.
bClosing cap (Cat. No. BCAP) is provided factory-installed on each device having “RB’’ suffix.
Price if ordered separately; $2.50
Table 1.51: Enclosure Dimensions
Dimensions
Box No. W H D
in. mm in. mm in. mm
1NM 6.52 166 8.79 223 3.90 99
1Ra4.88 124 9.38 238 4.00 102
2R 8.88 226 12.65 321 4.27 108
3R 14.75 375 18.92 481 4.52 115
4R 14.75 375 22.06 560 4.52 115
5R 14.75 375 26.04 661 4.52 115
6R 14.75 375 29.86 758 4.52 115
7R 14.75 375 33.78 858 4.52 115
8R 14.75 375 37.98 965 4.52 115
9R 4.56 116 6.50 165 3.88 99
10R 6.92 176 13.18 335 4.12 105
11R 7.56 192 23.24 590 4.75 121
12R 9.62 244 26.24 666 5.50 140
13R 6.92 176 16.18 411 4.12 105
14R 14.75 375 39.37 1000 4.52 115
15R 8.88 226 14.80 376 4.27 108
16R 8.55 217 24.75 629 4.16 106
17R 8.88 226 12.65 321 4.27 108
aHOME250SPA and QO260NATR top endwall has no hub opening.
Table 1.52: Knockout Information
Knockouts
Symbol A B C D E F G H
Conduit Size 1/2 in. 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in.
Table 1.53: Bolt-On Hubs UL Listed for “RB” Devicesb
Conduit Size 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in.
Hub Cat. No. B075 B100 B125 B150 B200 B250
$ Price 33.30 33.30 33.30 33.30 61.35 102.00
Table 1.54: Bolt-On Hubs UL Listed for Mounting in Field-Cut Opening
Conduit Size 3 in. 3-1/2 in. 4 in. Designed for mounting in field cut opening.
Includes gasket and four mounting bolts and nuts.Hub Cat. No. B300 B350 B400
$ Price 186.00 300.00 368.00
Box 3R, 4R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1
2
"
Hub Maximum
C,D,E,F A,B,C
Box 5R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1
2" Hub Maximum
C,D,E,F A,B,C
Box 6R, 7R, 8R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1
2
"
Hub Maximum
C,D,E,F A,B,C
Box 1NM
A,B B,C
A,B,C,D
A
Box 1R
A,B
2
1
2" Hub Maximum
B,C,D,E
B,C,D,E
A
Box 2R
A,B
2
1
2" Hub Maximum
B,C,D,E
Box 9R
A,B,C
A,B,C,D
C,D,E,F
Box 10R, 13R
B,C,D,E
B,C,D,E
2
1
2" Hub Maximum
D,E,F,G
Box 11R
2
1
2" Hub Maximum
“RB’’ Hub
D,E,F,G
Box 12R
2
1
2" Hub Maximum
E,F,G,H E,F
B,C,D,E
B,C,D,E
A
Box 15R
A,B
2
1
2" Hub Maximum
B,C,D,E
Box 16R
A,B
2
1
2" Hub Maximum
C,D,E,F
17R
212"Hub Maximum
B, C, D, E B, C, D, E
B, C, D, E
A
Power lnlet
Box 14R
2
1
2" Hub Maximum
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
C,D,E,F A,B,C
DE1A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-19
Combination Service Entrance Devices Rainproof, Meter Mains
Class 4119, 4120
Table 1.55: Meter Mains
Meets Federal Spec. W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1Ø3W, NEMA 3R enclosure
Ampere
Rating
Bypass
Type
Service
(Type of Feed)
Short Circuit
Current Rating
Cat. No. $ Price
Service Disconnect(s)
Load Center and Branch
Circuit Breakers (Order
separately Pages 1-2, 1-3, 1-4) Hub
Type
(Order
separately
from
page 1-17)
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
2P
Circuits
(Max.)
Type
(Order separately
from page 1-22
except as noted)
Ampere
Rating
(Max.)
Max. Quantity
Ampere
Rating
(Max.)
Spaces
1P
Circuits TandemsUL UL and
EUSERC
Ring Type
QO
Surface Mount Only
125 A None OH/UG 10 kA C125RB 368.00 1 QOM1-VH 125 A B 4–1/0 8–1/0 15, 54
200 A None
OH/UG 22 kA CM200S 1022.00 1 QOM2-VH 200 A A 4–250 (2) 8–2/0 26, 24
OH/UG 22 kA C2M200S 1083.00 1
1
QOM2-VH
QO-VH
200 A
50 A
A 4–250 (2) 8–2/0 27, 20
OH/UG 10 kA C4L200S 1143.00 2 QO 100 A A 4–250 (2) 8–2/0 27, 28
Homeline
Surface Mount Only
125 A None OH/UG OH/UG 10 kA SC8L125S 846.00 4 HOM 125 Ab A 6–2/0 6–2/0 31, 24
200 A None OH/UG OH/UG 10 kA SC12L200S 1419.00 6 HOM 200 Am A–L 4–250 8–2/0 40, 10
Semiflush Mount only
125 A None OH/UG OH/UG 10 kA SC8L125F 846.00 4 HOM 110 A A or B300 6–2/0 6–2/0 37, 20
200 A None OHd/UG OHd/UG 10 kA SC12L200F 1419.00 6 HOM 200 Aj A–L 4–250 8–2/0 47, 10
None OHd/UG OHd/UG 22 kA SC816F200Fe1187.00 1 QOM2200VHa200 A 8 16 8 200 AjA–L 4–250 8–2/0 51, 10
Surface Mount—Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
150 A None OH/UG
OH/UG 22 kA SC816F150Se1187.00 1 QOM2150VHa150 A 8 16 8 150 AnA–L 4–250 8–2/0 40, 10
10 kA SC816D150Cef 1250.00 1HOM2150a
HOM
150 A
50 A 8 16 8 100 AlA or A–L 6–300 8–1/0 48, 18
UG SU816D150Cef 1
200 A None OH/UG
OH/UG 22 kA SC816F200Se1187.00 1 QOM2200VHa200 A 8 16 8 200 AmA–L 4–250 8–2/0 40, 10
10 kA SC816D200Cef 1250.00 1 HOM2200a200 A
50 A 8 16 8 100 AlA or A–L 6–300 8–1/0 48, 18
UG SU816D200C ef 1250.00 1HOM
Ringless
QO
Surface Mount Only
200 A
None
OH/UG —
22 kA RC200Sg1022.00 1 QOM2-VH 200 A
—— —
A 6–350 (2)8–2/0 26, 24
Lever 10 kA RCM200SLgi 1950.00 1 QOM2-VH 200 A A 6–350 8-1/0 60 / 14
None 22 kA RC2M200Sg1083.00 1
1
QOM2-VH
QO-VH
200 A
50 A
A 6–350 (2)8–2/0 27, 20
Horn RC2M200SHg1136.00 A 6–350 (2)8–2/0 27, 20
Lever 10 kA RC2M200SLgi 2090.00 1 QOM2-VH 200 A A 6–350 8-1/0 60 / 14
1 QO-VH 50 A 8-1/0
None 22 kA QC12L200Spgi 1562.00 6 QO-VH 200 A A 6–350 8–2/0 43, 21
None 22 kA QC12L200Cg1562.00 6 QO-VH 200 AjA 6–350 12-2/0 40, 21
Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
100 A Horn OH/UG 22 kA QC816F100SHpegi 1356.00 1 QOM2100VHa100 A 8 16 8 100 A 6–350 8–2/0 43, 21
100 A Horn OH/UG 22 kA QC816F100CHegi 1356.00 1 QOM2100VHa100 A 8 16 8 100 A 6–350 12-2/0 40, 21
125 A
None OH/UG 22 kA QC816F125Segi 1304.00 1 QOM2125VHa125 A 8 16 8 100 A 6–350 8–2/0 43, 21
None OH/UG 22 kA QC816F125Ceg 1304.00 1 QOM2125VHa125 A 8 16 8 100 A 6–350 12-2/0 40, 21
Horn OH/UG 22 kA QC816F125SHpegi 1356.00 1 QOM2125VHa125 A 8 16 8 100 A 6–350 8–2/0 43, 21
150 A
None OH/UG 22 kA QC816F150Spegip 1304.00 1 QOM2150VHa150 A 8 16 8 150 AkA 6–350 8–2/0 43, 21
None OH/UG 22 kA QC816F150Ceg 1304.00 1 QOM2150VHa150 A 8 16 8 150 AkA 6–350 12-2/0 40, 21
Horn OH/UG 22 kA QC816F150SHpegi 1356.00 1 QOM2150VHa150 A 8 16 8 150 AkA 6–350 8–2/0 43, 21
Lever OH/UG 22 kA QC816F150SLqig 2690.00 1 QOM2150-VHa200 A 8 16 8 150 A A 6–350 8-2/0 74 / 12
200 A
None OH/UG 22 kA QC816F200Spegi 1356.00 1 QOM2200VHa200 A 8 16 8 200 AjA 6–350 8–2/0 43, 21
Horn OH/UG 22 kA QC816F200SHpegi 1356.00 1 QOM2200VHa200 A 8 16 8 200 AjA 6–350
Horn OH/UG 22 kA QC816F200CHeg 1356.00 1 QOM2200VHa200 A 8 16 8 200 AjA 6–350 12-2/0 40, 21
Lever OH/UG 22 kA QC816F200SLqig 2690.00 1 QOM2200-VHa200 A 8 16 8 200 A A 6–350 8–2/0 74 / 12
Homeline
Surface Mount Only
125 A None OH/UG 10 kA RC8L125So846.00 4 HOM 125 Ab A 6–2/0 6–2/0 27, 32
200 A None OH/UG 10 kA RC12L200Spgi 1419.00 6 HOM 200 Aj A 6–350 8–2/0 43, 21
200 A None OH/UG 22 kA QC12L200Cg1419.00 6 HOM 200 Aj A 6–350 12-2/0 40, 21
Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
100 A Horn OH/UG 22 kA RC816F100SHpegi 1227.00 1 QOM2100VHa100 A 8 16 8 100 A
A 6–350
8–2/0 43, 21
100 A Horn OH/UG 22 kA RC816F100CHegi 1227.00 1 QOM2100VHa100 A 8 16 8 100 A 12-2/0 40, 21
125 A Horn OH/UG 22 kA RC816F125SHpegi 1227.00 1 QOM2125VHa125 A 8 16 8 100 A 8–2/0 43, 21
125 A Horn OH/UG 22 kA RC816F125CHeg 1227.00 1 QOM2125VHa125 A 8 16 8 100 A 12-2/0 40, 21
150 A
None OH/UG 22 kA RC816F150Speg 1187.00 1 QOM2150VHa150 A 8 16 8 150 Ak8–2/0 43, 21
None OH/UG 22 kA RC816F150Ceg 1187.00 1 QOM2150VHa150 A 8 16 8 150 Ak12-2/0 40, 21
Horn OH/UG 22 kA RC816F150SHpegi 1227.00 1 QOM2150VHa150 A 8 16 8 150 Ak8–2/0 43, 21
Horn OH/UG 22 kA RC816F150CHegi 1227.00 1 QOM2150VHa150 A 8 16 8 150 Ak12-2/0 40, 21
Lever OH/UG 22 kA RC816F150SLqig 2690.00 1 QOM2150-VHa200 A 8 16 8 150 A 8-2/0 72 / 12
200 A
None OH/UG 22 kA RC816F200Spegi 1227.00 1 QOM2200VHa200 A 8 16 8 200 Aj8–2/0 43, 21
None OH/UG 22 kA RC816F200Ceg 1227.00 1 QOM2200VHa200 A 8 16 8 200 Aj12-2/0 40, 21
Horn OH/UG 22 kA RC816F200SHpegi 1227.00 1 QOM2200VHa200 A 8 16 8 200 Aj8–2/0 43, 21
Horn OH/UG 22 kA RC816F200CHegi 1227.00 1 QOM2200VHa200 A 8 16 8 200 Aj12-2/0 40, 21
Lever OH/UG 22 kA RC816F200SLqig 2690.00 1 QOM2200-VHa200 A 8 16 8 200 A 8-2/0 72 / 12
200 A Horn OH/UG 10 kA RC816D200CHefoi 1292.00 1 HOM2200a200 A 8 16 8 100 AlA or B300 6–300 6–1/0 48, 18
1 HOM 50 A
aService disconnect supplied factory-installed.
b125 A Homeline™ 2P circuit breaker can be installed in top position only. All other positions
are limited to 100 A max.
cUL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker
installed.
dSuitable for OH service with addition of tunnel kit SCTK20. Order separately.
eSupplied with load side feed-thru lugs, for 4 AWG–250 kcmil (Al/Cu) conductors.
fConvertible to semiflush with SC200F flange kit (order separately).
gDevice supplied with barrel lock provisions factory-installed.
h
i5th jaw factory-installed.
jUse only 15–100 A and 150–200 A circuit breakers.
kUse only 15–100 A and 150 A circuit breakers.
lA 100 A circuit breaker can be installed in bottom position only, all other positions are limited
to 70 A max.
mUse only 15–110 A and 150–200 A breakers.
nUse only 15–110 A and 150 A breakers.
oKnockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories, page
1-22).
pSuitable for load wires to exit top endwall with addition of Tunnel Kit OHBS, see accessories
p 1-22, check with local utility for approval.
qSuitable for load wires to exit top endwall with addition of Tunnel Kit OHBL, see accessories
p 1-22, check with local utility for approval.
DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-20 © 2012 Schneider Electric
All Rights Reserved
Combination Service Entrance Devices Rainproof, All-In-Ones
100 to 225 A Maximum Class 4120
Meter Mains and All-In-Ones
Ring or ringless type meter socket designs available
UL Listed, suitable only for use as service equipment
Meets EUSERC standards
Service disconnect(s) are supplied factory-installed, except
where noted
Semiflush-reverse design available, supplied with load center
(indoor access)
Supplied with 100% branch neutrals, all unused terminals
may be used for equipment grounding wires.
Meets Federal Specification W-P-115c as Type 1, Class 2
Table 1.56: All-In-One Combination Service Entrance Devices
Ampere
Rating
Bypass
Type
Service
(Type
of Feed)
UL and
EUSERC
Short Circuit
Current Rating
Cat. No.
(DE3A)
List
$ Price
Service Disconnect(s)
Load Center and Branch
Circuit Breakers
(Order Separately
Pages 1-2, 1-3, 1-14)
Hub Type (Order
Separately page 1-22)
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
Max. Quantity
Ampere
Rating (Max.)
Spaces
1P
Circuits
Tandems
2P
Circuits
(Max.)
Type
(Factory Installed)
Ampere
Rating
(Max.)
Ring Type
Homeline
Surface Mount Only
100 A None OH/UG 10 kA SC1624M100S 744.00 1 HOM2100 100 A 16 24 8 100 A A 6–2/0 6–2/0 32, 24
125 A None OH/UG 10 kA SC1624M125S 1518.00 1 HOM2125 125 A 16 24 8 125 Aa
200 A None OH/UG 22 kA SC2040M200S 1671.00 1 QOM2200VH 200 A 20 40 20 200 AkA-L 4–250 6–2/0 45, 10
200 A None OH/UGf10 kA SC2040M200C b1799.00 1 HOM2200 200 A 20 40 20 100 A A or A-L 6–300 8–1/0 47, 18
200 A None UG 10 kA SU2040M200Cb1799.00 1 HOM2200 200 A 20 40 20 100 A A or A-L 6–300 8–1/0 47, 18
Semiflush Mount Only
100 A None OH/UG 10 kA SC1624M100F 744.00 1 HOM2100 100 A 16 24 8 100 A A or
B300 6–2/0 6–2/0 44, 20
125 A None OH/UG 10 kA SC1624M125F 1518.00 1 HOM2125 125 A 16 24 8 110 A
OHc/UG 22 kA SC2040M125F 1671.00 1 QOM2125VH 125 A 20 40 20 110 A A-L 4–250 8–2/0 51, 10
200 A None
OHc/UG 22 kA SC2040M200F 1671.00 1 QOM2200VH 200 A 20 40 20 200 Ak
OHe/UG 22 kA SC2636M200FPVd2244.00 1 QOM2200VH 200 A 26 36 10 100 A
A-L 4–250 8–2/0 56, 10
SC3040M200F 2064.00 1 QOM2200VH 200 A 30 40 10 200 A
225 A None OHe/UG 22 kA SC3040M225F 2280.00 1 QOM2225VH 225 A 30 40 10 200 A
SC2636M225FPVd2520.00 1 QOM2225VH 225 A 26 36 10 100 A
Surface Mount Only
100 A None OHf10 kA SO1020M100S 443.00 1 HOM2100 100 A 10 20 10 80 A A 6–1 8–4 20, 42
200 A None OHf22 kA SO2040M200S 1161.00 1 QOM2200VH 200 A 20 40 20 200 A A 6–350 8–2/0 43, 21
200 A None OH/UG 22 kA SC3040M200S 2010.00 1 QOM2200VH 200 A 30 40 10 200 A A-L 4–250 8–2/0 50, 10
SC40M200S 2432.00 1 QOM2200VH 200 A 40 40 0 200 A 4–250 8–2/0 52, 10
REVERSE All-In-One—Semiflush Mount with Service Disconnect (outdoor access) and Load Center (indoor access)
200 A None UG 10 kA SU3040M200R 2223.00 1 QOM2200VH 200 A 30 40 10 200 AkA or
B300 6–300 12–1/0 60, 15
225 A None UG 10 kA SU3040M225R 2646.00 1 QOM2225VH 225 A
Ringless
Homeline
Surface Mount Only
100 A None OH/UGf10 kA RC1624M100S 744.00 1 HOM2100 100 A 16 24 8 100 A
A
6–2/0 6–2/0 32, 24
125 A RC1624M125S 1518.00 1 HOM2125 125 A 125 Aa
125 A Horn OH/UGf22 kA RC2040M125SHlg 1601.00 1 QOM2125VH 125 A 20 40 20 125 A
6–350 8–2/0
43, 21
125 A Horn OH/UGf22 kA RC2040M125CHgh 1601.00 1 QOM2125VH 125 A 20 40 20 125 A 40, 21
150 A
Horn OH/UGf22 kA RC2040M150SHlg 1713.00 1 QOM2150VH 150 A 20 40 20 150 A 43, 21
Horn OH/UGf22 kA RC2040M150CHgh 1713.00 1 QOM2150VH 150 A 20 40 20 150 A 40, 21
Lever OH/UG 22 kA RC3040M150SLm4900.00 1 QOM2150VHa200 A 30 40 10 150 A 76 / 12
200 A
None OH/UGf22 kA RC2040M200Slg 1713.00 1 QOM2200VH 200 A 20 40 20 200 A 43, 21
None OH/UGf22 kA RC2040M200Cg1713.00 1 QOM2200VH 200 A 20 40 20 200 A 40, 21
Horn OH/UGf22 kA RC2040M200SHlg 1713.00 1 QOM2200VH 200 A 20 40 20 200 A 43, 21
Horn OH/UGf22 kA RC2040M200CHg1713.00 1 QOM2200VH 200 A 20 40 20 200 A 40, 21
Lever OH/UG 22 kA RC3040M200SLm4900.00 1 QOM2200VHa200 A 30 40 10 200 A 76 / 12
None OH/UGf22 kA RC2040M200SGP 2602.00 1 QOM2200VH 200 A 20 40 20 200 A 48 / 21
QO
Surface Mount Only
150 A Horn OH/UGf22 kA QC2442M150SHlg 1905.00 1 QOM2150VH 150 A 24 42 18 150 A
A 6–350 8–2/0
43, 21
200 A
None OH/UGf22 kA QC2442M200Slg 1905.00 1 QOM2200VH 200 A 24 42 18 200 A 43, 21
None OH/UGf22 kA QC2442M200Cg1905.00 1 QOM2200VH 200 A 24 42 18 200 A 40, 21
Horn OH/UGf22 kA QC2442M200SHlg 1905.00 1 QOM2200VH 200 A 24 42 18 200 A 43, 21
Horn OH/UGf22 kA QC2442M200CHgh 1905.00 1 QOM2200VH 200 A 24 42 18 200 A 40, 21
200 A Hom OH/UGf22 kA QC3040M200SHl2120.00 1 QOM2200VH 200 A 30 40 10 200 A 40, 21
a125 A Homeline 2P circuit breaker can be installed in top position only. All other
positions are limited to 100 A max.
bConvertible to semiflush with SC200F flange kit (order separately).
cSuitable for OH service with addition of tunnel kit (SCTK20). Order separately.
dFor use with Photovoltaic Systems. Provisions for field-installed CT. If required by
adopted code, order retaining kit PK2SCPV separately. See page 1-22.
eSuitable for OH service with addition of tunnel kit (SCTK30). Order separately.
fDevice does not meet EUSERC Specifications.
gDevice supplied with barrel lock provisions factory-installed.
h5th jaw factory-installed.
iUse only 15–100 A and 150 A circuit breakers.
jUse only 15–100 A and 150–200 A circuit breakers.
kUse only 15–110 A and 150–200 A circuit breakers.
lSuitable for load wires to exit top endwall with addition of Tunnel Kit OHBS, see accessories
p 1-22, check with local utility for approval.
mSuitable for load wires to exit top endwall with addition of Tunnel Kit OHBL, see accessories
p 1-22, check with local utility for approval.
DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-21
Combination Service Entrance Devices Rainproof, Meter Mains and All-In-Ones
300400 A Devices Class 4119, 4120
Meter Mains and All-in-Ones
Ring or ringless type meter socket designs available
UL Listed, suitable only for use as service equipment
Meets EUSERC standards where indicated.
Service disconnects are supplied factory-installed, except where noted
Supplied with 100% branch neutrals; all unused terminals may be used for
equipment grounding wires
Meets Federal Specification W-P-115c as Type 1, Class 2
Table 1.57: Meter Mains
Meets Federal Specification W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1Ø3W, NEMA 3R Enclosure
Ampere
Rating
Bypass
Type
Service
(Type
of Feed)
Short Circuit
Current Rating
Cat. No. List
$ Price
Service Disconnect(s) a
Load Center and Branch
Circuit Breakers
(Order Separately
Pages 1-2, 1-3, 1-14)
Hub Type (Order
Separately page 1-22)
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
Max. Quantity
Ampere
Rating (Max.)
Spaces
1P
Circuits
TandemsUL UL and
EUSERC
2P
Circuits
(Max.)
Type
(Order separately
from page 1-22
except as noted)
Ampere
Rating
(Max.)
Ring Type
QO
Surface and Semiflush Mount b
400 A None UG UG 25 kA
CU12L400CN c3810.00 1 QDL22200 d200 A
A–L (2) Studs 4–250 98, 4
CU12L400FN c4007.00 1 QDL, QGL, QJLe200 A
4 QO, QO-VH or QOH 125 A h—— —
400 A
Class 320
Manual
Bypass
UG 25 kA
CU12L400CB ck 3986.00 1 QDL22200 d200 A
A–L (2) Studs 4–250 98, 4
CU12L400FB ck 4182.00 1 QDL, QGL, QJLe200 A
4 QO, QO-VH or QOH 125 A h—— —
400 A None UG UG 25 kA CU816D400CN ci 3975.00 1 QDL22200 d200 A 8 16 8 200 A A–L (2) Studs 4–250 98, 4
400 A
Class 320
Manual
Bypass
UG 25 kA CU816D400CB cik 4151.00 1 QDL22200 d200 A 8 16 8 200 A A–L (2) Studs 4–250 98, 4
400 A
Class 320
Manual
Bypass
UG 65 kAaCUM400CB ck 8688.00 1 DGP36400E20LHd400 A 2 f 200 A A–L (2) Studs 4–250 115, 4
Ringless Type
400 A
Class
320
Lever
UG 25 kA QU12L400SL gk 3810.00
1 QDL22200 d200 A
A–L (2) Studs 4–250 98, 41 QDL, QGL, QJLe200 A
4 QO, QO-VH or QOHm125 A h—— —
Surface Mount Only, Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers
400 A lUG 25 kA QU816D400SLigk 4065.00 1 QDL22200 d200 A 8 16 8 200 A A–L (2) Studs 4–250 98, 4
QU816D400CK ik 1 QDL, QGL, QJLe200 A
Surface and Semiflush Mount b
400 A
Class 320
Lever
UG 25 kA QU12L400CLgjk 3810.00 1 QDL22200 d200 A
A–L (2) Studs 4–250 98, 4
1 QDL, QGL, QJLe200 A
QU12L400FLgjk 4007.00 4 QO, QO-VH or QOH 125 A h—— —
400 A UG 25 kA QU816D400CLgjik 4065.00 1 QDL22200d200 A 8 16 8 200 A A–L (2) Studs 4–250 98, 4
QU816D400FLgjik 4262.00 1 QDL, QGL, QJLe200 A
400 A Class 320
Lever UG 65 kAaQUM400CLgk 10000.00 1 DGP36400E20LHd400 A 2 f 200 A A–L (2) Studs 4–250 120, 4
400 A K-4 Bolt- UG — 65kAaQUM400CKck 11175.00 1 DGP36400E20LHd400 A 2 f 200 A A–L (2) Studs 4–250 123, 4
None
Table 1.58: All-in-One Combination Service Entrance Devices
Ring Type
Homeline
Surface and Semiflush Mount b
300 A Class 320
Manual UG — 25 kA SU3040D300CB cjk 6600.00 1 QDL22200 d200 A 30 40 10 200 A A–L (2) Studs 4–250 100, 4
SU3040D300FB cjk 6797.00 1 QDL, QGL, QJLe100 A
400 A None UG UG 25 kA SU3040D400CN cj 7050.00 1 QDL22200 d200 A 30 40 10 200 A A–L (2) Studs 4–250 100, 4
SU3040D400FN cj 7247.00 1 QDL, QGL, QJLe200 A
400 A Class 320
Manual UG — 25 kA SU3040D400CBcjk 7167.00 1 QDL22200 d200 A 30 40 10 200 A A–L (2) Studs 4–250 100, 4
SU3040D400FB cjk 7364.00 1 QDL, QGL, QJLe200 A
Ringless
400 A Class 320
Lever UG — 25 kA RU3040D400CL gjk 6993.00 1 QDL22200 d200 A 30 40 10 200 A A–L (2) Studs 4–250 100, 4
RU3040D400FL gjk 7190.00 1 QDL, QGL, QJLe200 A
400 A K-4 Bolt-
on UG 25 kA RU3040D400CK jk 6993.00 1 QDL22200 d200 A 30 40 10 200 A A–L (2) Studs 4–250 100, 4
RU3040D400FK jk 7190.00 1 QDL, QGL, QJLe200 A
aUL short circuit current rating is equal to the lowest interrupting rating of any circuit
breaker installed.
bFor 400 A device with suffix CB, CK, CL, or CN, surface-mount convertible to semiflush
with FK400 flange kit (order kit separately). Devices wtih suffix FB, FL, FN or FK are
semiflush only, with the top endwall factory-installed and flanges factory-included.
cFor use only on 120/240 Vac 1Ø3W system (4-jaw meter socket).
dService disconnect supplied factory-installed.
eAdditional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25
kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker
catalog number, see Section 7.
fOption for field installation of two Q-frame, 200 A max. 2-pole branch circuit breakers used as
mains for two downstream load centers. Purchase installation kit BMK2Q400 and two
Q-frame circuit breakers separately. Order QBL prefix at 10 kA, QDL prefix at 25 kA, or QGL
prefix at 65 kA.
gFifth jaw factory-installed.
hQO panel is rated 200 A maximum.
iSupplied with load side feed-thru lugs for 6 AWG–250 kcmil (Al/Cu) conductors.
jKnockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories, page 1-
22).
kDevice configuration is not included in EUSERC standards. Consult applicable utility for
acceptance.
lDevice with suffix L has Class 320 lever bypass and device with suffix K has a K-4 bolt-on, no
bypass.
mOrder two pole circuit breakers for field installation: order catalog designation QO for 10 kA, QO-
VH for 22 kA or QOH for 42 kA short circuit current rating. See page 1-22 or 1-2.
1-22 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
Combination Service Entrance Devices Circuit Breakers, Accessories and Hubs
Class 4119, 4120
Table 1.59: Circuit Breakers for use with Meter Mains and All-In-One Devices
Ampere
Rating
a
Type: HOM, 1P Type: HOM, 2P Type: QO, 1P Type: QO, 2P Type: QO-VH, 1P Type: QO-VH, 2P
Cat. No.
(DE3D) $ Price Cat. No.
(DE3D) $ Price Cat. No.
(DE2A) $ Price Cat. No.
(DE2A) $ Price Cat. No.
(DE2A) $ Price Cat. No.
(DE2A) $ Price
10 QO110 29.10 —— —— —
15 HOM115 26.30 ——QO115 29.10 ——QO115VH 63.00 ——
20 HOM120 26.30 ——QO120 29.10 ——QO120VH 63.00 ——
25 HOM125 26.30 ——QO125 29.10 ——QO125VH 73.00 ——
30 HOM130 26.30 HOM230 60.00 QO130 29.10 QO230 67.00 QO130VH 73.00 QO230VH 146.00
35 HOM235 60.00 QO135 29.10 QO235 67.00 —— —
40 HOM140 26.30 HOM240 60.00 QO140 29.10 QO240 67.00 ——QO240VH 146.00
45 HOM245 60.00 QO145 29.10 QO245 67.00 —— —
50 HOM150 26.30 HOM250 60.00 QO150 29.10 QO250 67.00 ——QO250VH 146.00
60 HOM260 60.00 QO160 29.10 QO260 67.00 ——QO260VH 146.00
70 HOM270 123.00 QO170 67.00 QO270 134.00 ——QO270VH 224.00
80 HOM280 168.00 ——QO280 189.00 ——QO280VH 315.00
90 HOM290 168.00 ——QO290 189.00 ——QO290VH 315.00
100 HOM2100 168.00 ——QO2100 189.00 ——QO2100VH 315.00
110 HOM2110 369.00 ——QO2110 428.00 ——QO2110VH 1034.00
125 HOM2125 369.00 ——QO2125 428.00 ——QO2125VH 1034.00
150 HOM2150BB 428.00 ——QO2150 491.00 ——QO2150VH 1061.00
175 HOM2175BB 428.00 ——QO2175 491.00 ——QO2175VH 1061.00
200 HOM2200BB 428.00 ——QO2200 491.00 ——QO2200VH 1061.00
Ampere
Rating
a
Type: QOM1-VH, 2P Type: QOM2-VH, 2P Type: QDL, 2Pc
Cat. No. (DE3D) $ Price Cat. No. (DE3D) $ Price Cat. No. (DE2A) $ Price
50 QOM50VHb140.00 —— —
60 QOM60VH 140.00 —— —
70 QOM70VH 140.00 ——QDL22070 1143.00
80 QOM80VH 201.00 ——QDL22080 1143.00
90 QOM90VH 201.00 ——QDL22090 1143.00
100 QOM100VH 201.00 QOM2100VH 468.00 QDL22100 1143.00
110 QOM110VH 468.00 ——QDL22110 1143.00
125 QOM125VH 468.00 QOM2125VH 468.00 QDL22125 1143.00
150 — QOM2150VH 468.00 QDL22150 1143.00
175 — QOM2175VH 468.00 QDL22175 1143.00
200 — QOM2200VH 468.00 QDL22200 1143.00
225 — QOM2225VH 468.00 ——
aDo not exceed mains rating of device
bReference National Electrical Code Article 230-79.
cFor additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA.
Table 1.60: Accessories, Hubs and Closing Plates
Accessories Hubs and Closing Plates
Description Cat. No. $ Price Disc.
Sch.
Hub
Series
Conduit Size
(inches) Cat. No. $ Price Disc.
Sch.
Generator Kit: Interlocks main service disconnect and generator circuit breaker (order
separately). For :
Closing Plate for “A” Hub opening ACP 13.40 DE4
A
1.00 A100 33.90 DE4
Homeline CSED Devices RC816F-, RC2040M-, SO2040M- RCGK2 245.00 DE4 1.25 A125 33.90 DE4
QO CSED Devices QC816F-, QC2442M- QCGK3 245.00 DE4 1.50 A150 33.90 DE4
Backfed inverter circuit breaker retaining kit for SC2636M200FPV and SC2636M225FPV PK2SCPV 47.40 DE4
Fifth Jaw Kit for: Meter Main Types: C, RC, SC, QC
All-In-One Types: SC, SU (100–225 A), QC, RC, SO 5J 18.30 DE4 2.00 A200 47.90 DE4
2.50 A250 61.00 DE4
Bypass (Horn Type) for Ringless Type Meter Mains and All-In-Ones (100–200 A)
(except for RC8L125S, RC1624M100S and RC1624M125S–use RCHB). MMHB 16.70 DE4 Adapter plate to allow use of “A”
Hubs on “A-L” size hub openings
AAP 33.80 DE4
Lexan Meter Socket Cover Plate for:
Ring and Ringless Type Meter Mains
Ring and Ringless Type All-In-Ones
29007 10.10 DE4
Closing Plate for “A-L” Hub
opening ACPL 18.30 DE4
A-L
2.00 A200L d83.00 DE4
Meter Socket Sealing Rings for Ring Type Meter Mains and All-In Ones: 2.50 A250L 87.00 DE4
Snap Type Aluminum (Std.) 2920910001 7.95 DE5 3.00 A300L 111.00 DE4
Screw Type Aluminum 29008W 20.10 DE4 3.50 A350L 114.00 DE4
Snap Type Stainless Steel ARP00026 16.70 DE4 4.00 A400L 119.00 DE4
Anti-Inversion Kit . For use ONLY on 400 A Meter Mains and All-In-Ones with lever bypass. MMLRK 12.00 DE4 Closing Plate for “B” Hub opening BCAP 3.80 DE1A
Trim Kit for 2 in. X 6 in. stud wall, used with Reverse All-In-Ones, SU3040M200R, and
SU3040M225R SU2X6TRIM 266.00 DE4
B
0.75 B075 33.30 DE1A
1.00 B100 33.30 DE1A
Barrel Lock Kit (Barrel Lock not included), supplied with bracket and mounting screw, refer to
listings for where used. SCBRLLOCK 53.00 DE4 1.25 B125 33.30 DE1A
1.50 B150 33.30 DE1A
Semiflush Flange Kit for: Meter Mains: SC816D150/200C and RC816D200CH
All-In-Ones: SC2040M200C SC200F 31.80 DE4 2.00 B200 61.35 DE1A
2.50 B250 102.00 DE1A
Semiflush Flange Kit for ring- and ringless-type Meter Mains and All-In-Ones (400 A Only) FK400 197.00 DE4 B300 3.00 B300 186.00 DE1A
Ringless Type Utility Cover for RU3040D400CL/FL, QU12L400CL/FL, and QU816D400CL/FL.
Includes one piece meter socket and pull box cover with handles and closing plate. R400L 266.00 DE4 dSupplied with AAP adapter plate and “A” hub.
Lug Kit includes (4) lugs, for use with 2 AWG–600 kcmil Al/Cu conductors. Lugs are for standard
2-Hole mounting. Meter Main and All-In-One units supplied with (2) studs per phase and neutral
will accept one lug per phase and neutral. Not for use on 400 A devices with “K” suffix.
CMELK4 137.00 DE4
Branch Circuit Breaker Field Installation Kit for two Q-Frame Circuit Breakers (QBL, QDL, or
QGL, order separately). For CUM400CB, QUM400CL or QUM400CK - includes (2) mounting
pans, (4) wires.
BMK2Q400 153.00 DE4
Overhead Feed Trough for 400 A ring- and ringless-type Meter Mains and All-In-Ones. OCK400 567.00 DE4
Touch-Up Paint (ASA49 Gray) PK49SP 39.00 DE1
Ground Bar Kit, Meter Mains and All-In-Ones QC, RC, and SC (100–225 A) PK15GTA 17.10 DE3A
Filler Plate for: Meter Main Types: QC, CU All-In-One Types: QC QOFP 3.60 DE3A
Filler Plate for: Meter Main Types: RC, SC All-In-One Types: SC, RC, SU HOMFP 3.20 DE3A
Neutral Lug (6-2/0 AWG)
for: Meter Main Types: RC, SC, QC All-In-One Types: SC, SU, QC, RC LK100AN 10.80 DE3A
Overhead Barrier Tunnel Kit for Ringless & Horn Bypass in RC/QC Devices OHBS 86.00 DE4
Overhead Barrier Tunnel Kit for Lever Bypass RC/QC Devices OHBL 94.00 DE4
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-23
Combination Service Entrance Devices Dimensions
Class 4119, 4120
aDriphood supplied factory-installed and is required
for surface mount installation.
For semi-flush installation, remove driphood and
install flange kit SC200F (order separately).
bUnit supplied with blank top endwall (factory-
installed) for surface mount installation. For semi-
flush installation, install flange kit FK400 (order
separately). Kit includes replacement top endwall
(with knockouts) and flanges.
cUnit supplied with semi-flush top endwall factory
installed and semi-flush flanges factory included.
Table 1.61: Knockouts
Symbol A B C D E F G H I J
Conduit
Size (in.) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4
7.14
181
14.97
380A H
ub
Drip Hood
C,D,F A
B,C,D
7.50
191
Semi-Flush End Wall
28.28
718
4.60
117
12.80
325
7.44
189
13.82
351
“B” Hub
C125RB (Shown)
CQRB100
A,B C,D,E,F
Ring Type:
CM200S
C2M200S (Shown)
C4L200S
Ringless Type:
RC200S
RC2M200S
RC2M200SH
A,B E,F,G,H
D,F,G
18.23
463
10.70
272
19.58
497
“A” Hub
4.60
117
A,B
B,C
A
21/2" Max “A” Hub
13.46
342
4.56
116
SO1020M100S
C,D,E,F
20.79
528
6.44
164
7.50
191
8.00
203
41.25
1048
28.25
718
C,D,F
A
B,C
CU12L400CNc
CU12L400CBc
QU12L400CLc
QU12L400SL
CU12L400FNf
CU12L400FBf
CU816D400FNf
CU816D400FBf
QU816D400CK
QU12L400FLf
QU816D400FLf
CU816D400CBc
CU816D400CNc
QU816D400CLc
QU816D400SL (Shown)
Blank End Wall
G,H,I,J
“A-L” Hub
SU816D150Cq
(Shown)
SU816D200Cq
SU2040M200Cq
RC816D200CH
SC816D150C
SC816D200C
q
32.23
819
14.81
376
6.95
176
14.50
368
B,C C,D,F
21/2" Max “A” Hub
D,F,G
A,B
C,E,F,G,H
21/2" Max
“A-L” Hub
C,D,E,F B,C
B,C
A
10.87
276
25.12
638
14.77
375
SC8L125S (Shown)
RC8L125S
SC1624M100S
SC1624M125S
RC1624M100S
RC1624M125S
4.80
122
C,D,F
A
A,B
B,C
21/2" Max “A” Hub
21/2" Max
“A” Hub
D,F,G
Surface
2
1
/
2
" Max “A” Hub
10.94
278
40.93
1040
18.35
466
RC816F100SH
RC816F125SH
RC816F150S,SH
RC816F200S,SH
RC12L200S
RC2040M125SH
RC2040M150SH
RC2040M200S,SH
QC816F100SH
QC816F125SH
QC816F150S,SH (Shown)
QC816F200S,SH
QC12L200S
QC2442M150SH
QC2442M200S,SH
SO2040M200S
5.32
135
C,D,E,F
E,F,G,H
A,B,C
A,B
C,D,E,F
SC8L125F (Shown)
SC1624M100F
SC1624M125F
25.12
638
10.87
276
3.39
86
14.50
368
B,C
A,B
C,D,F
A
AA,B B,C
D,F,G
21/2" Max
“A” Hub or
B300
SU3040M200R (Shown)
SU3040M225R
14.62
371
31.61
803
48.00
1219
B,C B
B
B
D,F,G C,D
C,D,F A,B A
A
7.90
201
4.40
112
3.50
89
27.00
686
C
L
Meter
Socket
C
L
Top
Branch
Circuit
Breaker
“A” Hub or
B300 Hub
3.40
86
C,E,F,G,H
21/2" Max
“A-L” Hub
SC816F200F
SC12L200F
SC2040M125F
SC2040M200F (Shown)
SC3040M200F
SC3040M2225F
SC2636M200FPV
SC2636M225FPV
14.85
377
10.30
262
35.40
899
39.60
1006
A
A,B
C,D,E,F
35.40
899
C,D,E,F
B,C
A
B,C B
39.60
1006
21/2" Max “A” Hub
29.50
749
SC12L200S
SC816F150S
SC816F200S
SC40M200S
SC2040M200S (Shown)
SC3040M200S
5.80
147
21.50
546
C,E,F,G,H
21/2" Max
“A-L” Hub
A
B,C
B
C,D,E,F
11.10
282
32.30
820
37.30
947
SC40M200S
SC3040M200S
G,H,I,J
“A-L” Hub
8.00
203
SU3040D400CBc (Shown)
RU3040D400CLc
RU3040D400CKc
SU3040D300FBf
SU3040D400FBf
SU3040D400FNf
7.50
191
41.25
1048
28.25
718
C,D,F
A
B,C
Blank End Wall
SU3040D300CBc
SU3040D400CNc
RU3040D400FLf
RU3040D400FK
CUM400CB
QUM400CL
QUM400CK
c
q
q
f
c
c
c
12.57
319
48.62
1235
Lever ByPass Devices
QC3040M200SH
QC816F150SL
QC816F200SL
RC816F150SL
RC816F200SL
RC3040M150SL
RC3040M200SL
2
1
/
2
" Max “A” Hub
10.04
255
35.13
892
14.37
365
4.67
119
C,D,E,F
D,E,F,G
A,B,C
A,B
QC12L200C
QC816F100CH
QC816F150C
QC816F200CH
RC12L200C
RC816F100CH
RC816F125CH
RC816F200C
RC816F200CH
RC2040M125CH
RC2040M200CH
QC2442M200C
QC2442M200CH
RC816F150C
RC816F150CH
RC2040M150CH
RC2040M200C
QC816F125C
QC816F200C
1-24 © 2012 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
RC/QC Solar Ready CSED Devices Rainproof, Meter Mains and All-In-Ones
150 to 200 A Maximum Class 4120
Meter Mains and All-In-Ones
Ringless Meter Sockets with barrel lock provisions factory installed except for Cat. No. SO2040M200SS which is a Ring Style meter
socket with no provisions for barrel lock to secure the meter cover.
UL Listed, suitable only for use as service equipment
Service disconnect(s) are supplied factory-installed, except where noted
Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires.
Meets Federal Specification W-P-115c as Type 1, Class 2
Solar Ready kit SR69064A fits All Devices Below, order from Table 1.70
All devices have a 3" KO in the bottom endwall.
Provisions for Field Installed CTs All Devices
SC/SU SOLAR READY
CSED Devices Coming
Soon—See On-Line
Digest Updates for
Availability
Table 1.62: All-In-One Combination Service Entrance Devices
Ampere
Rating
Bypass
Type
Service
Type
Short Circuit
Current Rating
Cat. No. List
$ Price
Service Disconnect(s)
Load Center and Branch
Circuit Breakers
(Order Separately
Pages 1-2, 1-3, 1-14)
Hub Type (Order
Separately page 1-18)
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Max. Quantity
Ampere
Rating (Max.)
Spaces
1P
Circuits
Tandems
2P
Circuits
(Max.)
Type
(Factory Installed
except where noted)
Ampere
Rating
Meter Mainsh
QO
Surface Mount Only
Surface Mount—Supplied with Feed-Thru Lugs and Provisions for Branch Circuit Breakers
150 A None OH/UG 22 kA QC816F150SSbf 1408.00 1 QOM2150VH 150 A 8 16 8 150 A
A 350 8–2/0
Lever OH/UG 22 kA QC816F150SLSbg 2905.00 1 QOM2150VH 150 A 8 16 8 150 A
200 A None OH/UG 22 kA QC816F200SSbf 1408.00 1 QOM2200VH 200 A 8 16 8 200 A
Lever OH/UG 22 kA QC816F200SLSbg 2905.00 1 QOM2200VH 200 A 8 16 8 200 A
Homeline
Surface Mount—Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
150 A None OH/UG 22 kA RC816F150SSbf 1270.00 1 QOM2150VH 150 A 8 16 8 150 A A 6-350 8–2/0
Lever OH/UG 22 kA RC816F150SLSbg 2878.00 1 QOM2150VH 150 A 16 8 150 A A 6-350 8–2/0
200 A
None OH/UG 22 kA RC816F200SSbf 1270.00 1 QOM2200VH 200 A 8 16 8 200 A A 6-350 8–2/0
Horn OH/UG 22 kA RC816F200SHSbdf 1313.00 1 QOM2200VH 200 A 8 16 8 200 A A 6-350 8–2/0
Lever OH/UG 22 kA RC816F200SLSbg 2878.00 1 QOM2200VH 200 A 16 8 200 A A 6-350 8–2/0
All-in-One Combination Service Entrance Devicesh
QO
Surface Mount Only
200 A None OH/UG 22 kA QC2442M200SSf2057.00 1 QOM2200VH 200 A 24 42 18 200 A A 6-350 8–2/0
Horn OH/UG 22 kA QC2442M200SHSdf 2057.00 1 QOM2200VH 200 A 24 42 18 200 A A 6-350 8–2/0
Homeline
150 A Horn OH/UG 22 kA RC2040M150SHSdf 1833.00 1 QOM2150VH 150 A 20 40 20 150 A A 6-350 8–2/0
Lever OH/UG 22 kA RC3040M150SLSg2226.00 1 QOM2150VH 150 A 30 40 10 150 A A 6-350 8–2/0
200 A
None OH/UG 22 kA RC2040M200SSf1833.00 1 QOM2200VH 200 A 20 40 20 200 A A 6-350 8–2/0
Horn OH/UG 22 kA RC2040M200SHSdf 1833.00 1 QOM2200VH 200 A 20 40 20 200 A A 6-350 8–2/0
None OH 22 kA SO2040M200SSf1242.00 1 QOM2200VH 200 A 20 40 20 200 A A 6-350 8–2/0
Lever OH/UG 22 kA RC3040M200SLSg2226.00 1 QOM2200VH 200 A 30 40 10 200 A A 6-350 8–2/0
* Kit is to be installed between meter socket and Main Disconnect. May be used with Solar PV, Wind,
fuel generators, and other power generation sources up to 80% of Mains Rating Maximum 160 A.
aOrder two pole QO, QO-VH or QOH circuit breakers separately from page 1-22 or 1-2.
The short circuit current rating is equal to the lowest interrupting rating of any
circuit breaker installed.
bSupplied with load side feed-thru lugs, for 4AWG-250 kcmil Al/Cu conductors.
cRing style device. Barrel lock provisions not provided.
dDevice supplied with horn bypass and 5th jaw factory installed
eOrder two pole Homeline circuit breakers separately from page 1-22.
fSuitable for load wires to exit top endwall with addition of Tunnel Kit OHBS.
See accessories p 1-22, check with local utility for approval.
gSuitable for load wires to exit top endwall with addition of Tunnel Kit OHBL.
See accessories p 1-22, check with local utility for approval.
hSolar Ready Kit Part Number SR69064A * (This Kit Fits All Solar Ready Devices)
List Price: $78.00
2
1
/
2
" Max A Hub
10.94
278
40.9
3
1040
18.35
466
5.32
135
C,D,E,F
E,F,G,H
A,B,C
A,B
12.57
319
48.62
1235
Lever ByPass Devices
RC816F150SS
RC816F200SS
RC816F200SHS
QC816F150SS
QC816F200SS
RC2040M150SHS
RC2040M200SS
RC2040M200SHS
SO2040M200SS
QC2442M200SS
QC2442M200SHS
QC816F150SLS
RC816F150SLS
RC3040M150SLS
QC816F200SLS
RC816F200SLS
RC3040M200SLS
Table 1.63: Knockouts
Symbol A B C D E F G H I J
Conduit
Size (in.) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4
DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-25
Enclosed Devices
Class 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—240 Vac—UL Listed
Table 1.64: Enclosed Molded Case Switch, Switch Included,
Does NOT provide overcurrent protection
Service Ampere
Rating
General Purpose Rainproof Box. No.
See Page
1-17
Cat. No. $ Price Cat. No. $ Price
240 Vac 60 Aab
QO260NATS
161.00
QO200TR 161.00 2, 9Rc
QO200TRNM 191.00 1NM
QO260NATR 168.00 1R
120/240 Vac 100 AdQO2000NS 276.00 QO2000NRB 338.00 13, 10R
Table 1.65: Housing Bracket
Description Cat. No. $ Price
Bracket used with QO200TR for stucco, aluminum and vinyl siding.
Order quantity multiples of 10. PKHB 6.30
QO200TRNM QO3100BNF
With Cover Removed
PKHB
Housing
Bracket
Table 1.66: Enclosed GFCI Circuit Breakers, GFCI Circuit Breaker
Included—10 kA Short Circuit Current Rating
Service Ampere
Rating
Type 3R—Rainproof Circuit Breaker
Included
Box. No.
See Page
1-17
Cat. No. $ Price
120/240 Vac 50 A QOE250GFINM
HOME250SPA
528.00
473.00
QO250GFI
HOM250GFI
1NM (Non-
metallic)
1R (Metallic)
Table 1.67: 2-Pole Circuit Circuit Breaker Enclosures—22 kA
Short Circuit Current Rating
Not for use with one pole QO or QOVH breakers. Circuit breakers not included. Order
QO, QOVH, QO-GFI, QO-AFI, QO-EPD and QO-PL circuit breakers separately from pages
1-2 and 1-3. Accepts QO circuit breakers with factory-installed accessories. Order
equipment ground bar PKOGTA2, if required.
Service Ampere
Rating
General PurposeeRainproof Box. No.
See Page
1-17
Cat. No. $ Price Cat. No. $ Price
120/240
Vac
100 A
125 A
QO2100BNF/S
QO2125BNF/S
83.00
108.00
QO2100BNRB
QO2125BNRB
135.00
158.00
13, 10R
18, 13R
240 Vac 100 A QO3100BNF/S 149.00 QO3100BNRB 207.00 13, 10R
Table 1.68: 60A Max. Circuit Breaker Enclosures—10 kA Short
Circuit Current Rating
Circuit breaker not included. Order separately from page 1-2. Will not accept QO-GFI
circuit breaker nor QO circuit breakers with factory-installed accessories.
240 Vac 60 A a——QO2TR 95.00 9Rc
Table 1.69: Q Frame Enclosures and Q Frame Circuit Breakers
Service
Enclosure OnlygCircuit Breaker (Order Separately)
Type 1—General Purpose eType 3R—Rainproof Box No.
See Page
1-17
Ampere
Rating
10 k AIR 25 k AIR 65 k AIR 100 k AIR
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
2P 240 Vac
Maximum
Q22200NS h
or
Q23225NF/S
176.00
218.00
Q22200NRBh
or
Q23225NRB
380.00
417.00
19, 11R
20, 12R
70 A QBL22070 474.00 QDL22070 1143.00 QGL22070 1521.00 QJL22070 1890.00
80 A QBL22080 474.00 QDL22080 1143.00 QGL22080 1521.00 QJL22080 1890.00
90 A QBL22090 474.00 QDL22090 1143.00 QGL22090 1521.00 QJL22090 1890.00
100 A QBL22100 474.00 QDL22100 1143.00 QGL22100 1521.00 QJL22100 1890.00
110 A QBL22110 474.00 QDL22110 1143.00 QGL22110 1521.00 QJL22110 1890.00
125 A QBL22125 474.00 QDL22125 1143.00 QGL22125 1521.00 QJL22125 1890.00
150 A QBL22150 474.00 QDL22150 1143.00 QGL22150 1521.00 QJL22150 1890.00
175 A QBL22175 474.00 QDL22175 1143.00 QGL22175 1521.00 QJL22175 1890.00
200 A QBL22200 474.00 QDL22200 1143.00 QGL22200 1521.00 QJL22200 1890.00
225 A QBL22225 474.00 QDL22225 1143.00 QGL22225 1521.00 QJL22225 1890.00
3P 240 Vac Q23225NF/S 218.00 Q23225NRB 278.00 20, 12R
70 A QBL32070 1248.00 QDL32070 1784.00 QGL32070 2442.00 QJL32070j2796.00
80 A QBL32080 1248.00 QDL32080 1784.00 QGL32080 2442.00 QJL32080j2796.00
90 A QBL32090 1248.00 QDL32090 1784.00 QGL32090 2442.00 QJL32090j2796.00
100 A QBL32100 1248.00 QDL32100 1784.00 QGL32100 2442.00 QJL32100j2796.00
110 A QBL32110 1248.00 QDL32110 1784.00 QGL32110 2442.00 QJL32110j2796.00
125 A QBL32125 1248.00 QDL32125 1784.00 QGL32125 2442.00 QJL32125j2796.00
150 A QBL32150 1248.00 QDL32150 1784.00 QGL32150 2442.00 QJL32150j2796.00
175 A QBL32175 1248.00 QDL32175 1784.00 QGL32175 2442.00 QJL32175j2796.00
200 A QBL32200 1248.00 QDL32200 1784.00 QGL32200 2442.00 QJL32200j2796.00
225 A QBL32225 1248.00 QDL32225 1784.00 QGL32225 2442.00 QJL32225j2796.00
Table 1.70: QOM2 Enclosures and QOM2 Circuit Breakers
Service
Enclosure OnlyfQOM2 Circuit Breaker
(Order Separately) i
Type 1
General Purposee
Type 3R
Rainproof
Box No.
See
Pages
1-17
Ampere
Rating
22 k AIR
Cat. No. $ Price Cat. No. $ Price Cat. No.k$ Price
2P 240 Vac
Maximum
QOM22225NF/S 234.00 QOM22225NRB 440.00 22, 16R
100 A QOM2100VH 468.00
125 A QOM2125VH 468.00
150 A QOM2150VH 468.00
175 A QOM2175VH 468.00
200 A QOM2200VH 468.00
225 A QOM2225VH 468.00
aNot suitable for service equipment.
bMaximum 10 hp 240 Vac.
cTop endwall has no hub opening.
dMaximum 20 hp 240 Vac.
eOrder F for flush, S for surface.
fEquipment ground bar kit PKOGTA2
factory-included.
gFactory-installed groundable neutral assembly
includes (2) ground lugs and (2) neutral lugs.
Equipment ground kit PKOGTA2 also included.
hAccepts 200 A max. 2P Q Frame circuit breakers.
iAdd suffix 1021 for 120, 208 or 240 Vac shunt
trip. Add $126.
jWhen these 3P circuit breakers are mounted in
an enclosure, the maximum AIR rating is 65 kA at
240 Vac and 100 kA at 208 Vac.
kDE3A Discount Schedule.
Q22200NS
With Cover Removed
(Order Q-Frame circuit breaker separately)
Q23225NF
QOM22225NS
With Cover Removed
DE2A DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-26 © 2012 Schneider Electric
All Rights Reserved
Servicepak Power
Outlet Panels
Class 1140
For Construction Sites
Provide temporary power at construction sites.
Each receptacle protected by QO-GFI circuit breaker in compliance with NEC®
requirements.
Each enclosure is rainproof.
10 kA short circuit current rating.
UL Listed as suitable for use as temporary site service equipment.
Provided with neutral bonding provisions.
Boxes have provisions for type “B’’ hubs to be field-installed.
For Recreational Vehicle Parks
Provide electrical power to individual recreational vehicle park sites.
Each receptacle protected by appropriate GFI or Standard QO circuit breaker.
All receptacles and circuit breakers included.
10 kA short circuit current rating.
UL Listed.
All enclosures are rainproof.
No neutral bonding provisions.
Loop-feed provisions.
a(1Ø2W 120 Vac) (1Ø3W 120/240 Vac)
b20 A receptacles protected by 20 A GFI circuit breaker.
cDevices have a bolt-on factory-installed closing cap. Order type “B’’ bolt-on hub separately from page 1-18.
dEquipment ground terminal suitable for (2) 14 or 12 AWG Cu or (2) 12 or 10 AWG Al.
eReceptacles in this device are in bottom endwall and are accessible with outer door padlocked.
“Order Only’’ from Lexington—Minimum order quantity is 50 devices.
fTwo wires each per phase, neutral, and equipment ground—for loop feed (except PAK75CTG).
gEquipment ground terminal suitable for (2) 14–12 AWG Cu or (2) 12–10 Al.
hGFI circuit breaker can be substituted for standard 30 A circuit breaker. For 30 ampere receptacles add $140.00 per
circuit breaker. Add suffix "FI’’ to catalog number. Example: PAK41CTGFI.
iStabilizer foot available for use in unstable ground, order HNPSF $27.50 list.
jEquipment ground terminals suitable for (2) 10–2/0 AWG Cu or (2) 6–2/0 AWG Al.
Table 1.71: Construction Site Panels
Power
Outlet
Configuration
Service
a
Mains
Ampere
Rating
Circuit Breaker
(Included)
Receptacles
(Included) Cat. No.c$ Price
Main Wire Size
AWG d
A C D E F Cu Al
1C 1Ø2W 40 A (1) QO120GFI 1 PAK 1 0 C 1 441.00 14–6 12–6
2C 1Ø2W 40 A (2) QO120GFI 2 PAK11Ce818.00 14–6 12–6
2C 1Ø2W 40 A (2) QO120GFI 2 PAK 1 1 C 1 818.00 14–6 12–6
3C 1Ø3W 70 A (1) QO120GFI
(1) QO230GFI 11PAK31CGFI 974.00 8–1 8–1
4C 1Ø3W 70 A (1) QO120GFI
(1) QO220GFI 11 PAK36C1GFI 974.00 8–1 8–1
5C 1Ø3W 70 A (1) QO120GFI
(1) QO250GFI 11PAK51CGFI 974.00 8–1 8–1
6C 1Ø3W 70 A (1) QO120GFI
(1) QO250GFI 11 PAK55CGFI 974.00 8–1 8–1
7C 1Ø3W 70 A (2) QO120GFI
(1) QO220GFI 21 PAK72CGFI 1323.00 8–1 8–1
8C 1Ø3W 70 A (2) QO120GFI
(1) QO250GFI 21 PAK76CGFI 1323.00 8–1 8–1
9C 3W 100 A (1) QO120GFI
(2) QO250GFI 12 PAK1004CGFI 1581.00 14–1 12–1
T
T
TTT
T
T T
TT
TT TT
TTT
T T
T
TT
T
1C 2C 3C
4C 5C 6C
8C
TTT
7C 9C
10C 11C 12C
13C 14C
(For Dimensions/Drawings go to Supplemental
Digest, hardcopy or on-line version.)
20 A 125 V 2W and Grd.
NEMA 5-20R
30 A 125 V 2W and Grd
ANSI 73.13
50 A 125/250 V 3W and Grd.
NEMA 14-50R
20 A 250 V 2W and Grd.
NEMA 6-20R
30 A 125/250 V 3W and Grd.
NEMA 14-30R
50 A 250 V 2W and Grd.
NEMA 6-50R
All non-pedestal devices have provisions to field-
install a Type “B’’ hub on the bottom endwall for
bottom feed from a conduit riser. Order Type “B’’
bolt-on hub (B250 Max.) and two mounting screws
(Cat. No. 8002505501) and two hex nuts (Cat. No.
2340102000).
A
B
C
D
E
F
Table 1.72: Recreational Vehicle Park Panels
Power Outlet
Configuration
Service
a
Mains
Ampere
Rating
Circuit Breaker
(Included)
Receptacles
(Included) bCat. No. $ Price
Main Wire Size
AWG/kcmil f
Phase and Neutral
ABC Cu Al
Underground or Overhead Loop-Feed Terminals—Non-Pedestal cg
11C 1Ø2W 40 A (2) QO120GFI 2 PA K 11CTG 795.00
14–6 12–6
12C 1Ø2W 50 A (1) QO120GFI
(1) QO130 11 PAK41CTGh564.00
(2) QO130 12–1
14C 1Ø3W 100 A
(1) QO120GFI
(1) QO250
(1) QO130
111 PAK75C T G
(Not Loop Feed) h669.00 14–1 12–1
Pedestal Mounted—Underground Loop-Feed Terminals ij
11C 1Ø2W 40 A (2) QO120GFI 2 PAK11PG 1035.00
(2)6–250 (2)6–250
12C 1Ø2W 50 A (1) QO120GFI
(1) QO130 11 PAK41PG h852.00
13C 1Ø2W 75 A (1) QO120GFI
(2) QO130 12 PAK61PG h914.00
14C 1Ø3W 100 A
(1) QO120GFI
(1) QO250
(1) QO130
111 PAK75PG h1007.00
DE4 Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
© 2012 Schneider Electric
All Rights Reserved 1-27
QO Load Centers Indoor, 1Ø, Main Lugs and Main Breaker
Class 736, 1130 / Refer to Catalog 1100CT0501
QO Plug-on Neutral Load Centers and CAFI Breakers connect are engineered for a quick Plug-on Neutral
connection on every unit.
aDoor kit available separately Order QOCDK60 $237.00.
bAll OUTDOOR devices are available FACTORY ORDER only.
QO-K
Key operated QO circuit breakers are available in single-pole construction and can be mounted in any single-pole
space which will accept a standard QO. These circuit breakers can be turned ON or OFF or to RESET with a special
key (catalog number QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available
as shown in the table.
Table 1.73: QO Plug-on Neutral CAFI Load Center (accepts QO Circuit Breakers only)
Mains
Rating Spaces
Max.
1P
Circuits
Max.
Tandem
Breakers
$ Price
(Interior,
Box &
Cover)
Load Center Box and
Interior
Indoor Cover with Door
(Order Separately)
Main Wire
Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately
If Priced)
Box No.
See
Page
1-17
Cat. No. $ Price Flush
Cat. No.
Surface
Cat No. $ Price Al/Cu Cat. No. $ Price
I
N
D
O
O
R
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Copper Bus
QOM1 Main Frame Size, Convertible to Main Circuit Breaker
125 A 24 24 0 572.00 QO124L125PG 534.00 QOC24UF QOC24US 37.70 6–2/0 PK15GTA 7
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Copper Bus
QOM2 Main Frame Size, Convertible to Main Circuit Breaker
200 A 30 30 0 684.00 QO130L200PG 597.00 QOC30UF QOC30US 87.00 6–250 PK23GTA, LK100AN 9
225 A 42 42 0 1018.00 QO142L225PG 907.00 QOC42UF QOC42US 111.00 6–300 (2) PK15GTA 11
54 54 0 1356.00 QO154L225PG 1177.00 QOC54UF 179.00 PK23GTA, LK100AN 12
Convertible Mains — Factory-Installed Main Circuit Breaker — 22 kA Short Circuit Current Rating — Copper Bus
QOM1 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Lower Amperage Main Circuit Breaker
100 A 24 24 0 743.70 QO124M100P 706.00 QOC24UF QOC24US 37.70 6–2/0 PK15GTA 17.10 7
Convertible Mains — Factory-Installed Main Circuit Breaker — 22 kA Short Circuit Current Rating — Copper Bus
QOM2 Main Circuit Breaker Frame Size, Convertible to Main Lugs or Lower Amperage Main Circuit Breaker
200 A
30 30 0 1069.00 QO130M200P 982.00 QOC30UF QOC30US 87.00
4–250
PK18GTA 18.80 9
42 42 0 1410.00 QO142M200P 1299.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
54 54 0 1720.00 QO154M200P 1541.00 QOC54UF 179.00 PK23GTA 21.30 12
60 60 0 1956.00 QO160M200PCa1689.00 QOC60UFa267.00 PK23GTA 21.30 24
O
U
T
D
O
O
R
b
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Cu Bus
QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
125 A 24 24 0 712.00 QO124L125PGRB 712.00 6–2/0 PK15GTA 4R
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating — Cu Bus
QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
200 A 30 30 0 856.00 QO130L200PGRB 856.00 6–250 PK23GTA, LK100AN 6R
225 A 42 42 0 1500.00 QO142L225PGRB 1500.00 6–300 (2) PK15GTA 8R
Convertible Mains — Factory-Installed Main Circuit Breaer — 22 kA Short Circuit Current Rating — Copper Bus
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),
QOM1 Main Circuit Breaker Frame Size
100 A 24 24 0 1144.00 QO124M100PRB 1144.00 6–2/0 PK15GTA 17.10 4R
Convertible Mains — Factory-Installed Main Circuit Breaer — 22 kA Short Circuit Current Rating — Copper Bus
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),
QOM2 Main Circuit Breaker Frame Size
150 A 30 30 0 1344.00 QO130M150PRB 1344.00
4–250
PK18GTA 18.80 6R
200 A 30 30 0 1344.00 QO130M200PRB 1344.00 PK18GTA 21.30 6R
42 42 0 1659.00 QO142M200PRB 1659.00 PK23GTA 21.30 8R
Table 1.74: QO Arc Fault Circuit Breakers
Circuit Breaker
Type
Ampere
Rating
1P 120 Vac 1P 120 Vac
10 k AIR 22 k AIR
1 Space Required 1 Space Required
Cat. No. $ Price Cat. No. $ Price
Combination Arc-fault
Interrupter
(Pigtail Neutral)
15 QO115CAFI 282.00 QO115VHCAFI 534.00
20 QO120CAFI 282.00 QO120VHCAFI 534.00
Plug-On Neutral
Combination Arc-fault
Interrupter
15 QO115PCAFI 282.00 QO115VHPCAFI 534.00
20 QO120PCAFI 282.00 QO120VHPCAFI 534.00
Table 1.75: QO-K Circuit Breakers
120 Vac—10 k AIR (1 Space Required)
Ampere
RatingcCat. No. $ Price
10 QO110K 164.00
15 QO115K 164.00
20 QO120K 164.00
25 QO125K 164.00
30 QO130K 164.00
QO154M200P
DE2A DE3A Discount
Schedule
www.schneider-electric.us
1LOAD CENTERS
1-28 © 2012 Schneider Electric
All Rights Reserved