Bridge Best Practice Protocol1 Checklist
Consensus from 30 Extracting Physicians

Best Practice Protocol Summary
Prepare (all patients)

Practice

Perform

1.	 Place 0.035” super stiff guidewire from right

4.	 Bridge familiarity

7.	 Immediate
deployment when
SVC tear is suspected,
including tamponade
and/or hemothorax

femoral vein to right IJ.

2.	 Insert introducer sheath: 12F or 6F peel away
3.	 Prefilled syringe (48 cc saline with 12 cc
contrast) & Bridge immediately available

5.	 Bridge
competence
6.	 Bridge prophylaxis

Prepare: Every Patient, Every Extraction
¨¨ Place 0.035” super stiff guidewire, 260 cm length.
¨¨ Place from right femoral vein to right internal jugular.
·· Alternative access: left femoral vein and right or left subclavian vein. If femoral access is not
possible, a wire and sheath can be placed from a superior venous approach.
·· Use of ultrasound to facilitate access is highly recommended.
¨¨ Clamp the wire just outside the introducer and/or to the drape cloth to prevent movement.

¨¨ Insert introducer sheath. 12F required for Bridge delivery.
·· Alternatively, a 6F peel away with 12F pre-loaded on the wire may be utilized.

¨¨ Pre-fill syringe with 80/20 saline & contrast mix.
¨¨ Pre-fill 60cc syringe with 48 cc saline and 12 cc contrast, with the two-way stopcock attached.

¨¨ Confirm Bridge Occlusion Balloon is immediately available.
¨¨ Review anatomical markers for potential balloon deployment.

¨¨ Team communication: roles and emergent deployment workflow.
¨¨ Discuss workflow with the anesthesiologist, surgeon and team.
¨¨ Determine steps for diagnosis and treatment if a pericardial effusion is suspected.
¨¨ Plan how fluids will be delivered. (Meds/fluids delivered superior to Bridge will not be effective.)
¨¨ Determine when fluoroscopy will be moved to make way for
opening the chest.
¨¨ Select team member(s) for:
¨¨ Managing the guidewire while Bridge is advanced.
¨¨ Giving chest compressions.
¨¨ Managing the pocket if hemostasis is required.

“With SVC perforations, time
is of the essence. Any scenarios
that may delay deployment of
Bridge should be avoided.”1

Practice: Prophylaxis Considerations
Situations that may warrant staging Bridge in the IVC:
¨¨ Have several initial practice deployments been conducted?
¨¨ Has the team practiced the workflow recently in a non-emergent setting?
¨¨ Is this a high-risk case?
¨¨ Combined lead age >10 Years
¨¨ Low BMI
¨¨ Low LV ejection fraction
¨¨ ICD leads

¨¨ Multiple implanted leads (≥4)
¨¨ Female patients
¨¨ Dual Coil ICD leads

¨¨ Intra-procedure: Has the perceived risk increased and made the case high-risk?
¨¨ Have multiple extraction tools been used?

Perform: Bridge Emergent Deployment

NOTE: Guidewire must stay in place
during Bridge positioning and inflation

¨¨ Immediate deployment as soon as SVC tear is suspected, including cardiac
tamponade, hemothorax, or both.
¨¨ Remove protector before loading onto the wire. No flushing or prep required.
¨¨ Advance balloon over wire until proximal marker band on balloon is at SVC/RA junction.
¨¨ Maintain wire control and ensure wire does not pull back.
¨¨ Remove extraction sheath.
¨¨ Inflate with 30-60 cc of fluid and close stopcock on syringe to prevent deflation. Guidewire should not be removed
while Bridge is inflated.
¨¨ Do not position balloon too low; it may block atrial preload and increase risk of migration.

¨¨ Diagnostics
¨¨ Pericardiocentesis (ONLY if it does not delay surgery)
¨¨ Perform surgical repair
NOTE: The availability of Bridge in no way obviates the need for emergent cardio thoracic
surgical backup. Delay to definitive treatment is potentially life-threatening.
Bridge Occlusion Balloon Important Safety Information
The Bridge Occlusion Balloon is indicated for use for temporary vessel occlusion of the superior vena cava in applications including
perioperative occlusion and emergency control of hemorrhage. Use of the Bridge Occlusion Balloon in procedures other than those
indicated is not recommended.
The adverse events associated with an occlusion balloon procedure include, but are not limited to allergic reactions, death,
embolization, hematoma, hemorrhage, sepsis/infection, short-term hemodynamic deterioration, thromboembolic episodes,
vascular thrombosis, vessel dissection, vessel perforation, vessel spasm.
In order to facilitate rapid delivery, it is recommended that a guidewire is in place in the superior vena cava prior to beginning the
lead extraction procedure. Attempting to place the guidewire after a tear has occurred may:
•	 Result in an inability to traverse the superior vena cava with the guidewire
•	 Result in the guidewire exiting the vasculature at the tear site
•	 Result in an inability to place the Bridge Occlusion Balloon catheter
•	 Delay or prevent the ability to achieve occlusion
This information is not intended to replace a discussion with your healthcare provider on the benefits and risks of this procedure to
you.
Refer to spectranetics.com for Bridge IFU.
1. Wilkoff BL, Kennergren C, Love CJ, Kutalek SP, Epstein LM, Carrillo R, Bridge to Surgery: Best Practice Protocol Derived From Early
Clinical Experience with the Bridge Occlusion Balloon. Heart Rhythm (2017), doi: 10.1016/j.hrthm.2017.07.008.
©2017 Spectranetics. All rights reserved. Approved for external distribution. D030338-03 072017

Always Reaching Farther

Corporate Headquarters
The Spectranetics Corporation
9965 Federal Dr., Colorado Springs, CO 80921
Tel: 719-447-2000 • Fax: 719-447-2022
Customer Service: 800-231-0978



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01
Create Date                     : 2017:08:17 09:19:08-06:00
Metadata Date                   : 2017:08:17 09:19:09-06:00
Modify Date                     : 2017:08:17 09:19:09-06:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Instance ID                     : uuid:526aba8e-d874-3b40-9c92-a0c5b9b3b798
Original Document ID            : xmp.did:6be9f6c2-1d69-4df1-81ae-167a2bdc5c85
Document ID                     : xmp.id:da8d2e43-3de7-450d-b8ec-a93e0234f64a
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:caac3170-20cf-4dd5-af57-5bb88e2d5f93
Derived From Document ID        : xmp.did:caac3170-20cf-4dd5-af57-5bb88e2d5f93
Derived From Original Document ID: xmp.did:6be9f6c2-1d69-4df1-81ae-167a2bdc5c85
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Macintosh)
History Changed                 : /
History When                    : 2017:08:17 09:19:08-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 2
Creator                         : Adobe InDesign CC 2017 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu