Part Number Quick Reference . . . . . . . . . . . . . . H2
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . H3
Application Guide . . . . . . . . . . . . . . . . . . . . . H4-H5
Specification Project Information. . . . . . . . . . . . . H7
Heavy/Industrial Marine . . . . . . . . . . . . . . . . . . . H8
MaxGard®Interconnection Systems. . . . . . . H9-H30
J-Line Interconnection Systems. . . . . . . . . H31-H43
Washdown Industrial and Light Marine . . . . . . . H44
DuraGard®Waterproof Connections . . . . . H45-H54
FS/FD10-30A Metallic. . . . . . . . . . . . . . . H55-H65
Mechanically Interlocked
Receptacles. . . . . . . . . . . . . . . . . . . . . . H66-H68
UniGardPin and Sleeve
IEC Connector . . . . . . . . . . . . . . . . . . . . H69-H88
Dura-TiteOverview and Product
Comparison . . . . . . . . . . . . . . . . . . . . . . H89-H94
Ever-Lok®Locking Connectors. . . . . . . . . H95-H113
Control Circuits Connectors . . . . . . . . . . H114-H124
Heavy Duty Tumbler Switches. . . . . . . . H125-H126
Industrial Interlocked Receptacles . . . . . H127-H137
Hazardous Duty Plugs
Receptacles and Interlocks . . . . . . . . H138-H142
Delayed Action Receptacles
(EFS and DA) . . . . . . . . . . . . . . . . . . H143-H144
Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . H145
Static Ground Receptacle . . . . . . . . . . . . . . . . H146
Safe Ground Indicator System
(GSUL) . . . . . . . . . . . . . . . . . . . . . . . H147-H149
Computer System Interconnections . . . . H150-H158
H
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 1
If Cat. # Product Line Ordering Info/ Prior Catalog New Catalog Section
begins with Parts Reference in this Catalog
Begins on page…
31** thru 35** Angle Type 480V Tech. Svcs. PR-1 see prior separate catalog only
36** thru 39** FS/FD-Computer Sys. H58, H152 PR-5-, DP-1 Washdown &-Computer Syst.
4**** Hazardous Duty H139 PR-4-MG-1 Hazardous Location
5******* DuraTiteH91 DG-1 Industrial/Commercial
71** thru 75** Angle Type 600V Tech. Svcs. PR-1 see prior catalog
7X****** FS/DS-Computer Sys. H58, H152 PR-5, DP-1 Washdown &-Computer Syst.
80** thru 83** Standard EverLok®H96 PR-2 Industrial/Commercial
84** Heavy Svc. EverLok®H108 PR-2 Industrial/Comemrcial
85** & 86** Standard EverLok®H96 PR-2 Industrial/Commercial
87** thru 89** Midget EverLok®H100, H101 PR-2 Industrial/Commercial
8X****** MaxGard®H16 MG-1 Heavy Industrial/Marine
9****** DuraGard®H49 DG-1 Washdown/Light Marine
91** & 93** Discontinued – PR-2
9X****** DuraGard®H51, H52 DG-1 Washdown/Light Marine
A******** Angle Type Tech. Svcs. PR-1 see prior catalog
AA***** UnigardH81 IEC-1 Washdown/Light Marine
B,C or F***** Specials Tech. Svcs.
BE******* UnigardH81 J-1 Heavy Industrial/Marine
CFC***** Interlocks H133 PR-6 Controls/Interlocks
D****** MaxGard®H16, H141 MG-1 Heavy Industrial Marine
ER2**** Computer Sys. H158 DP-1 Computer Systems
ERS***** Interlocks H131 PR-6 Controls/Interlocks
FS***** FS/FD-Computer Sys. H65, H154 PR-5, DP-1 Washdown &-Computer Syst.
GC** Safe Ground H146 CD-1 Hazardous Location
GSUL*** Safe Ground H149 CD-1 Hazardous Location
J******* J-Line H36 J-1 Heavy Industrial/Marine
JB******* J-Line H35 J-1 Heavy Industrial/Marine
RS**** UnigardH74 IEC-1 Washdown/Light Marine
SGC* Safe Ground H149 CD-1 Hazardous Location
SGR** Safe Ground H149 CD-1 Hazardous Location
SK****** Control Circuits H116, H118 PR-2, PR-5 Controls/Interlocks
TH****** Interlocks H130 PR-6 Controls/Interlocks
For U.S. Customer Service and Order Inquiries, call 1-800-816-7809 or fax 1-800-816-7810.
For International Service and Order Inquiries, call (U.S.) 901-252-5400 or fax 901-252-1330.
For Canadian Customer Service and Order Inquiries, call 450-347-5318 or fax 450-347-1976.
For U.S. Technical Services, call 1-888-862-3289 or fax 901-252-1321.
For International Technical Services, call (U.S.) 901-252-5000, enter 1, 6672.
For tool service and repair, call 1-800-284-TOOL (8665).
For technical questions, call 1-888-862-3289.
Part Number Quick Reference
®
®
E2630, E47956, E5239, E10765 LR14096, C22.2-182
Unless otherwise noted, all products in this catalog are covered by one or more Agency Listings.
NOTES: 1. Many Russellstoll devices exceed competitor specifications. For any Competitive Cross-References, contact Technical Services.
2. Certain catalogs such as Angle Type will continue to be individually supported for replacement items.
Fax on Demand responses may include additional information useful in your application.
H2 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 2
Application Guide
This catalog has been divided into sections based on standard application groups. Each application group has been color-
coded for your convenience. Below is a description of each of the six general categories Russellstoll products fall in.
Applications are not limited to those listed below.
Heavy Industrial / Marine Applications: Outdoor, Severe or High Abuse Environments
• Industrial hook-ups
• Shore to ship power connections
stations
• Portable generator sets
• Mills & process plants
• Agriculture
• Portable power connections
• Aerospace manufacturing and
airports
• Lift stations
Irrigation & wastewater equipment
• Industrial and shipyard welding
• Power distribution centers
• Job site power: For telephone power
and communications equipment
Washdown & Light Marine Applications: Watertight / Waterproof
• Food processing plants
• Pharmaceutical manufacturing
• Bottling and beverage plants
• Barge and workboat applications
• Pulp & paper factories
• Outdoor construction sites
Industrial and Commercial Applications
• Entertainment (lighting & sound
systems)
• Machinery
• Computer related equipment
• Welding installations
• Construction sites
• Facilities electrical power
Control Circuit and Industrial / Interlock Applications
Automotive/Industrial Interlock
systems were designed for the
needs of the manufacturing
industry. These devices are used
where safety requirements mandate
a mechanically interlocked system
for connection and removal of
plugs under full load.
• Automatic press
• Heavy duty portable welding
• Portable systems
• Machine tool control or Servo systems
• Shipyard maintenance power
• Battery chargers
• Automated welder applications
• Food processing
• Temporary power connections
Hazardous Location Applications: Class I, Div. 1 / Class II, Div. 1
• Aerospace
• Steel mills and mining
• Petroleum
• Chemical
• Food processing
• Waste treatment
Computer Systems: Data Center and OEM Products
• Raised Floor Applications • Main Power Connections • Critical power for test,
instrumentation, telephone and
medical equipment
H4 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 4
Amperage
20 30 50 60 100 200 400/
600
Heavy Industrial / Marine
MaxGard®✔✔
J-Line✔✔
Washdown & Light Marine
DuraGard®✔✔✔
FS/FD✔✔
Mechanically Interlocked ✔✔✔
Receptacles
UniGard(IEC) IP67 ✔✔ ✔
Industrial & Commercial
DuraTite✔✔
Standard Everlok®(+Midget) ✔✔✔
Heavy Service Everlok®✔✔
UniGard(IEC) IP44 ✔✔ ✔
Control Circuit & Industrial Interlock
Control Circuit Connectors
Industrial Interlock Systems ✔✔ ✔
(Custom Products)
Hazardous Location
MaxGard®✔✔
Interlocked Switch Receptacles ✔✔
Delayed Action Circuit
Breaking Receptacles ✔✔
Tumbler Switches ✔✔
Safe Ground Indicator System —————————————————
Computer Systems
FS/FD & Angle Type DP ✔✔✔✔
Spec Grade ✔✔✔
DuraGard®✔✔✔
UniGard(IEC) ✔✔ ✔
Application Guide
Page H150 to H158
Page H138 to H149
Page H114 to H137
Page H44 to H88
Page H89 to H113
Page H8 to H43
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H5
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 5
Fax Quote
Request Form
T&B Russellstoll Specification Project Information: RFQ
(Copy and Fax)
Regional Office: __________________ Inquiry Date: ___________________________
File or quote (T&B): __________________ Response Date: ___________________________
Customer Name: __________________ Project Contact: ___________________________
Installation Site: __________________ Position/Company: ___________________________
Customer Contact: __________________ Contact Phone: ___________________________
Position: __________________ Contact Fax/Email: ___________________________
Customer Phone: __________________ Other: ___________________________
T&B Rep & Phone: __________________ ___________________________
T&B Rep. Fax/Email: __________________ ___________________________
Please fill out as much information as possible; better information makes a better bid!
Project Type: (circle) [New/Expanded Facility] [New Equipment] [Competitive Replacement]
Other/Note: __________________________________________________
Specification Project Information
1. Application/Usage How used, connectors for…
or System What is needed or requested.
Heavy Duty or Standard Service?
2. Environment & Indoor or Outdoor; Washdown?
Operational Chemical, XP or other needs.
Temperature range service issues
3. Amperage & Voltage Full load motor amps (3 phase?)
System Amperage or Request
Note any DC apps./specials
4. Poles/Wires & Cable XpYw & cable type & O.D.
& Control Contacts? Control Contacts? & why needed.
Conductor stranding — Superflex?
5. Enclosure Specs & Switched, Fused, Circuit Breaker
Mounting (Interlocks) NEMA style and cast aluminum/brass
Environmental / usage issues
6. Competitive Issues Competitor ratings or specs
List Cat. #’s, qty’s, prices
Direct mate or crossover OK?
7. Response Type and Quantities, pricing issues
Timing Budget info or formal quote
Project schedule for bids
8. Other Requirements: Specs or drawings needed
Issues or Drawings Other competitive / channel issues
Special colors, coatings, specs
Added device features requests
Fax this form to: 901-252-1321 Technical Services: Call 1-888-862-3289
outside U.S. (901) 252-5000, enter 1, 6672
Thanks for Specifying Russellstoll: The Maximum in Safety, Durability and Performance!
Specification Definition Information
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H7
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 7
H
Russellstoll ®
The widest range and toughest
construction. Safety, Durability
and Performance by design, in
copper-free cast aluminum epoxy
powder coated housings. Built to
last, from 30 through 400/600 amp
application, with a full interlock
line too. Optional 2 control
contacts and over 200 individual
voltage polarization options
through 600VAC/250VDC, 4P5W.
“O” ringed sealed pins, sleeves
and interiors.
Tough service in metal for many
industrial applications, the J-Line
offers a value alternative to
MaxGard in 3P4W, 30-200 Amp
applications with less severe
needs. Unique among
competitors, the J-Line uses a
reversible contact carrier for
maximum flexibility in many
portable service applications.
Heavy Industrial / Marine
Defined
Marine
Lighting Systems
Shore to Ship Power
Welding Stations
Power Distribution Centers
Shipboard Power Outlets
Barge Power Connection
Construction &
Agricultural
Generator Sets & Systems
Portable Tools & Equipment
Irrigation Systems Panels
Portable Lighting & Equipment
Government Municipal
and Utilities
Portable Building Power
Army Corps of Engineers
Utilities Panels
Emergency Power Systems
Sewage Pumping Stations
Light & Controls
Telephone Vault Systems
Cellular Telephone Masts
OEM’s
GenSet & Welding Systems
Transportable Equipment
MaxGard
4P5W + 2 Opt.
30 thru 400/600A
J-Line
4P4W Max.
30 thru 200A
Typical Application Groups
Russellstoll Line Selections for Outdoor (and Indoor) Applications
Any application where electrical connections need
protection from water and/or dust ingress to contacts or
wiring compartment.
Cable-to-connector sealing and watertight device locking
designs are critical.
Metal connectors are usually preferred for long service life.
H8 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 8
H
Russellstoll ®
MaxGard®Interconnection Systems
30-400/600 Amp, (30-200A Load Breaking) Maximum 600 VAC /250 VDC
Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles
Safety
Waterproof construction: standard neoprene “O” ringed
interior components provide environmental separation at
the front of each device; they don’t have to be connected
together just to be called “watertight.”
Different power supply ratings can’t mix: 24 single rated
device polarizations ensure exact voltage, frequency and
phase differentiation plus a few specials too. In every
current range.
Plugs stay in: Standard delayed action pull & turn
withdrawal offers all plugs an XP rating (30– 100 amps). All
system components use mating screw collars.
Foreign objects stay out: All receptacles and connectors
have a gated rotating disk on the face of the interior,
engaged on insertion.
Durability
At last – Durability: Rugged cast aluminum housings with
2 layers of electrostatic epoxy coating are standard, along
with stainless steel hardware. Available with flap or screw
covers. Interiors are molded from a tough reinforced UL94
VØ thermoset polyester.
The best connections for life: Pins and Sleeves are made
from CDA 360 and Marine grade CDA 485 brass; 200 and
400 amp lines are silver-plated as well.
The most power available in the most packages: 30, 60,
100, 200 and 400 amp lines in one system with cast
aluminum NEMA 4X interlocks, steel 30, 60 and 100 amp
NEMA 12 interlocks, or cast aluminum XP interlocks in 30,
60 and 100 amp ranges.
Performance
Any configuration you need: Through 4 pole 5 wire
configurations, all have a safety center earth ground pin
design that makes-first and breaks last. This applies to all
of our plugs, connectors, receptacles, male inlets and
inter-lock systems.
More control available: Two optional pilot/control pins for
contactors, load monitor circuits, shunt trip or any other
communication functions you need.
Ease of assembly: Solderless pressure type screw
terminals with hex socket heads and rear-access take
apart housings provide quick wiring access. No interior
removal required for wiring receptacles and connectors.
More Power: 150% non-UL ratings allow extending
MaxGard installations to 600 AMP custom loads, with
separate disconnect service.
Benefits
Russellstoll®builds a variety of benefits into one plug,
receptacle and interlock system for your application.
The MaxGard system. MAXimum Safety, Durability and
Performance in electrical interconnections.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H9
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 9
H
Russellstoll ®
Electrostatic epoxy powder
coat finish for maximum
corrosion resistance.
CDA 485 Marine grade
brass pins and sleeves.
Neoprene “O” rings on
pins, sleeves and
interiors provide
environmental separation
and true waterproof
integrity.
Acme threads prevent
“freezing” of screw
collars and covers.
Padlock-out access hole in
plug shroud provided as
standard safety feature.
Compression-type gland
bushing for optimal cable seal.
Center Ground Contacts:
Make First, Break Last
Optional Control/Pilot Contacts:
Make Last, Break First
Extra thick-wall
back boxes.
300 series stainless
steel hardware for
corrosion resistance
(entire line).
Copper free cast
aluminum housings.
Optional pilot contacts
available for control or
electrical interlocking.
Extra long current contacts
with deep well arc
containment.
Gated dead front construction.
Delayed insertion/removal keyways
provide XP approval for standard 30, 60
& 100 amp plugs.
Hex type pressure
terminals to ensure
tighter connections.
Available up to 4P5W + pilot;
Circuit Interrupting / Load
Breaking 30 to 200 amps.
Plug and Receptacle with Angle Adapter and Junction Box
MaxGard®Interconnection Systems
30-400/600 Amp, (30-200A Load Breaking) Maximum 600 VAC /250 VDC
Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles
H10 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 10
H
Russellstoll ®
Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)
Thick wall cast copper-free
aluminum housing with
epoxy powder coat finish.
NEMA 4X interlocks
available in 30-400 amp
ranges through 4P5W,
with 2 optional
pilot/control contacts.
Heavy on/off handle adds
mechanical to electrical
interlock function.
(External Lockout
Option kit available)
Gated, rotating dead-front
receptacle.
Watertight = Screw cap cover
Splashproof = Flap cover
Standard conduit
openings through top or
side. (cutaway shown)
(Optional sizes &
locations)
Standard, high A/C or
NA/breaker switch.
(cutaway shown)
Options include:
• Shunt Trip
• Auxiliary Switch
• Trip Ratings
Heavy duty sliding bar
interlock mechanism.
(Mates with plug
padlock-out access
hole)
Protective screw
cap (flap cap also
available).
MaxGard®Interconnection Systems
30-400/600 Amp, (30-200A Load Breaking) Maximum 600 VAC /250 VDC
Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H11
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 11
H
Russellstoll ®
Fused-Disconnect Switch* Interlocked Receptacle
Available in 30, 60 and 100 amp sizes, all polarizations thru 600VAC.
Standard 600V cartridge
fuse clips and spacing.
Clear shield for
test probes.
Three
external
lockout
points.
Door
safety
switch.
Backup door
safety latch.
Heavy .060 steel galvaneel
with baked enamel, NEMA
3R/12 construction.
Consult Technical Services
for additional options.
Meets Federal specification
WS865C, UL File #E5239.
Meets UL 98, 50, 1682, 508, 231
Meets NEC Table 373-6(b).
Meets major automotive specs.
* Also available as switch-only
Angled front receptacle
for easier access.
Fully interlocked
MaxGard receptacle.
Safety fuse pulls.
MaxGard®Interconnection Systems
30-400/600 Amp, (30-200A Load Breaking) Maximum 600 VAC /250 VDC
Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles
H12 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 12
H
Russellstoll ®
Explosion-Proof Waterproof Circuit Breaker Interlocked Receptacle
Available in 30, 60 and 100 amp sizes, all polarizations.
MaxGard®DBRE and DSRE series interlocks are
explosion proof and waterproof, (O-ring sealed)
along with optional control contacts, fully UL listed.
MaxGard®Interconnection Systems
30-400/600 Amp, (30-200A Load Breaking) Maximum 600 VAC /250 VDC
Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion Proof Interlocked Receptacles
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H13
Heavy duty XP cast aluminum
housing, electrostatic epoxy
coat finish.
Standard, high AIC and NA
(switched only) breakers available.
Threaded access (cover not
shown) with “O” ring for XP and
waterproof integrity.
Gated
dead-front
safety.
Drain Plug.
Factory sealed receptacle interior. Accepts
standard XP rated MaxGard plugs.
UL and CSA listed for hazardous locations.
Class I, Division 1, Groups B, C and D
Class II, Division 1, Groups F and G
UL File E10919
NEMA 7, 8, 9
CSA
D.O.T. shipboard used above deck “green water”
NEMA 4X
USCG approved.
Explosion-Proof Waterproof Non-Interlocked Receptacle
Available in 30A 480VAC max., all polarizations.
Heavy duty XP cast aluminum
housing, electrostatic epoxy
coat finish.
• Factory Sealed Interior
(no filled conduits).
• Easy low cost installation.
Threaded access with (cover
not shown) “O” ring for XP and
waterproof integrity.
Gated dead-front for safety.
All standard polarizations
available to 480VAC.
Factory sealed receptacle
interior. Accepts standard XP
rated MaxGard plugs.
UL and CSA listed for hazardous locations.
Class I, Division 1, C and D
Class II, Division 1, Groups F and G
UL File E10919
NEMA 7, 8, 9
CSA
D.O.T. shipboard used above deck “green water”
NEMA 4X
USCG approved.
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 13
H
Russellstoll ®
Rating for Pilot/Control Contacts*
Contact Rating Code Designation A-600, Table 119.1 - U.L. 508 Heavy Pilot Duty Load (720 VA/600 VAC) Maximum
Thermal
Continuous Maximum Current, Ampere
Current Amps 120V 240V 480V 600V Max Volt Ampere
Make Break Make Break Make Break Make Break Make Break
10 60 6 30 3 15 1.5 12 1.2 7200 720
Engineering Specifications
Pin & Sleeve Plugs, Receptacles & Systems
1.0 Scope
1.1 This document covers multi-contact: pin & sleeve,
industrial grade, arc-quenching, circuit interrupting
rated electrical plugs, motor plugs, connectors,
receptacles, mechanically interlocked receptacles
and assorted accessories. Usable in dry, damp, wet,
marine and/or hazardous locations for electrical power
circuits. Devices are to be rated 30, 60, 100, 200 and/
or 400 amperes at 600 VAC, 50-400 Hz and 250 VDC
maximum. Devices are also rated for continuous use
in temperatures from -40 degrees C to + 130 degrees
C. These devices must provide internal environmental
seals for marine and extreme wet applications and
can be electrically interlocked.
1.2 The devices described shall be Thomas & Betts/
Russellstoll MaxGard catalog numbers as specified.
2.0 Product Classifications (Features)
2.1 Gated Dead Front – All receptacles and connectors
must have a rotating disk on the face of the interior
which provides live contact isolation and
environmental separation.
2.2 Delayed Action Arc Containment All devices upon
disconnect under load shall have provision so the arc
is contained and extinguished within the insulation
cavity making it impossible to withdraw a live plug.
2.3 Flap Cover or Screw Cover Option – Flap cover
option must provide weathertight capability by utilizing
a spring actuated self closing flap. Watertight
capability shall be obtained by using a gasketed crew
cap.
2.4 Polarization – All devices shall be factory polarized
for amperage, voltage, frequency and phase; thus
providing a single voltage rating, single interface
system.
2.5 Grounding – The grounding of the device shall be
accomplished through a separate center ground
(earth) make-first and break-last pole on all devices
for complete system grounding.
2.6 Pole Capabilities – All devices shall accommodate
up to four power pins plus a separate center ground
pin and they shall be integral with the connector
bodies (5 pins total).
2.7 Interior Type – Interiors must be male (pin type) or
female (sleeve type). Pins and sleeves shall also be
self-aligning and self-wiping/self-cleaning.
2.8 Control Contacts – All devices must have an option
for two control contacts which shall be make-last and
break-first for use in electrical interlocks and/or control
circuits. See table below.
2.9 Conductor Terminals – Pin and sleeve connections
shall employ solderless pressure type screw terminals
and be sized to accept stranded or solid copper
conductors in AWG sizes (max. O.D.’s as noted). The
screw terminals shall also have socket heads to insure
proper torquing of wires.
2.10 Environmental Seals – Each device must have an
environmental seal or “O” ring around all interiors and
around each pin and sleeve to prevent water and
contaminants from entering the wiring compartment.
This provides waterproof capability, even when not
mated.
2.11 Hazardous Location – All standard plugs 30, 60 and
100 amp shall be UL and CSA listed for hazardous
location Class I Division 1, Groups C & D; Class II
Division 1, Groups F & G. A hazardous location
circuit-breaker protected interlock shall also be
applicable to the same environments and possess all
the same product features as outlined above.
Enclosures shall meet NEMA 8 hazardous outdoor
duty classifications and shall meet shipboard use
above deck in accordance with the Department of
Transportation. (USCG “Green Water”)
2.12 Lockout Devices – Plug connection lockout is
achieved by a padlock through plug sleeve housing
hole provided for this purpose. On Hazardous
Location/Explosion Proof Interlock Receptacles,
lockout shall additionally be achieved by separate
lockout accessory available from the factory. On
standard Interlocks, lockout accessory/construction is
available from the factory.
2.13 Horsepower Ratings – Horsepower ratings shall be
in accordance with NEC Article 430 conditions,
depending on applicable voltage up to 600 VAC. See
Chart Next Page.
MaxGard®Interconnection Systems
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
H14 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 14
H
Russellstoll ®
MaxGard®Interconnection Systems
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Maximum Horsepower Ratings*
Service Connection Use: Not for normal disconnect
service, but plug may be withdrawn if necessary within
these maximum HP ratings.
Plug and Full Load - Motor Rated HP
Receptacle 120 240 480 600
Amp Rating Volts Volts Volts Volts
Single-phase 30 2 3 7.5 10
60 3 10 20 20
100 7.5 15 30 30
200 15 30 40 40
Three-phase 30 3 7.5 15 20
60 7.5 15 30 30
100 10 20 40 40
200 20 40 50 50
* Use of a horsepower rated switch for motor disconnection (under load) is
recommended per NEC 430.
2.14 Disconnect (Non-Interrupting) Current Ratings –
Devices may be used at up to 150% of rated current
within applicable NEC wiring guidelines. When used
at 150% ratings, device shall not make or break
current loads while in service. UL approved 45 amp
(30) and 150 amp (100) polarizations are available; for
other ratings and special polarizations, consult
factory.
3.0 Materials Requirements
3.1 Housings – Plug, motor plug, receptacles,
connectors and interlock housings, associated covers
and caps, screw collars, and clamp holders shall be
made of copper-free cast aluminum (max. .004%
copper).
3.2 Finish – All external surfaces except those that
provide means of grounding shall be epoxy powder
coated to resist corrosion.
3.3 Hardware – All hardware, external and springs, shall
be stainless steel. Cable clamps shall be stainless
steel or epoxy powder coated copper-free cast
aluminum.
3.4 Insulators – All device body insulators shall be
molded from glass-reinforced high strength thermoset
polyester, minimum of UL94VØ flammability rated.
3.5 Contacts – Contacts base material shall be made of
a conductive copper alloy, (brass CDA485) to prevent
dezincification. Accessory material of the contacts
shall be made of a compatible corrosion resistant
material.
3.6 Environmental Seals – Environmental gaskets and
“O” rings shall be made of neoprene material.
4.0 Design and Construction Requirements
4.1 Circuit Interrupting Rating – All devices 30, 60, 100
and 200 amperes shall be tested to be interrupted at
150% of rated current. Additionally, all devices shall
be designed and tested to interrupt 100% of rated
current.
4.2 Wiring – All devices shall be wired from the rear
requiring no disassembly of the pins and/or sleeves
from the insulated body.
5.0 Applicable Documents (Compliances)
5.1 Underwriters Laboratories (UL) – The devices
specified herein shall be listed in applicable sections
of UL Standards 1010, 231, 1682 and 1686, File Nos.
E2630, E57324, E68085, E123752.
5.2 Canadian Standard Association (CSA) – The
devices specified shall be listed in the applicable
sections of CSA C22.2-182.1, File Number LR14096.
5.3 International Electro-Technical Commission (IEC) –
The 30, 60 and 100 ampere devices specified shall
have been tested and comply with IEC 309-1.
5.4 Federal Department of Transportation –
Refrigerated National Shipboard location devices shall
meet and comply with Federal Register volume 47,
number 68, subpart 111.79.
5.5 Standards – The devices specified shall comply with
Military Standards MIL-STD-105 and 1344; ASTM
Standards D570 and D2565: NEMA Standard PR4-
1983; and OSHA regulations when installed in
accordance with the National Electrical Code (NEC).
5.6 NEMA 250 Enclosures Standard
NEMA-1 – General Purpose for indoor use; guards
against contact with equipment.
NEMA-3R – Outdoor use primarily to protect against
rain, sleet, wind-blown dust and damage from
external ice formation.
NEMA-4 – Indoor or outdoor use to protect against
windblown dust and rain; splashing and hose directed
water.
NEMA-4X – Watertight, dust-tight corrosion-resistant
for indoor or outdoor applications.
NEMA-6 – Watertight, casual/temporary immersion.
NEMA-7 - Class I (Hazardous) for indoor use in Class
I areas, per NEC.
NEMA-8 - Class I (Hazardous) for indoor use in Class
I, oil-immersed equipment.
NEMA-9 – Class II (Hazardous) for indoor use in Class
II areas, per NEC.
NEMA-12 – Industrial use, dust-tight for indoor use to
protect against dust, failing dirt and dripping non-
corrosive liquids.
Engineering Specifications (Continued)
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H15
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 15
Standard Ratings Std. Std.
Poles Bushing Bushing
Wires Voltage Cat. No. I.D.** Cat. No. I.D.** Cat. No.
30 Amp / 45* ▼▼
2P3W 125 DS3107MP000 g" DF3107FP000 g" DS3107MR000
2P3W 250 DS3207MP000 g" DF3207FP000 g" DS3207MR000
3P4W 125/250 DS3307MP000 1" DF3307FP000 1" DS3307MR000
3P4W 3Ø 480 DS3404MP000 1" DF3404FP000 1" DS3404MR000
4P5W 3ØY 277/480 DS3504MP000 1i" DF3504FP000 1i" DS3504MR000
60 Amp / 90*
2P3W 250 DS6207MP000 1i" DF6207FP000 1i" DS6207MR000
3P4W 125/250 DS6307MP000 1j" DF6307FP000 1j" DS6307MR000
3P4W 3Ø 480 DS6404MP000 1j" DF6404FP000 1j" DS6404MR000
4P5W 3ØY 277/480 DS6504MP000 1d" DF6504FP000 1d" DS6504MR000
100 Amp / 150*
2P3W 250 DS1207MP000 1W" DF1207FP000 1W" DS1207MR000
3P4W 125/250 DS1307MP000 1m" DF1307FP000 1m" DS1307MR000
3P4W 3Ø 480 DS1404MP000 1m" DF1404FP000 1m" DS1404MR000
4P5W 3ØY 277/480 DS1504MP000 2" DF1504FP000 2" DS1504MR000
200 Amp / 300*
3P4W 277/480 DS2304MP000 2b" DF2304FP000 2b" DS2304MR000
3P4W 3Ø 480 DS2404MP000 2b" DF2404FP000 2b" DS2404MR000
4P5W 3ØY 277/480 DS2504MP000 2d" DF2504FP000 2d" DS2504MR000
400 Amp / 600*
3P4W 277/480 DS4304MP000 3" DF4304FP000 3" DS4304MR000
3P4W 3Ø 480 DS4404MP000 3" DF4404FP000 3" DS4404MR000
4P5W 3ØY 277/480 DS4504MP000 3b" DF4504FP000 3b" DS4504MR000
*
MaxGard®Interconnection Systems
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
All available voltage
polarizations
on pg. H20.
Maximum
600 VAC
250 VDC, Load
Breaking
Male Plug Female Connector• Male Inlet
** Special Disconnect Service Ratings Available (Consult Factory)
150% non-UL ratings (consult technical services) with separate disconnect service.
** Standard cable bushings shown. Additional sizes available, see page H26.
Always furnished with screw collar. We recommend cup cap with male inlet and male plug;
order catalog number DS(X)CC. (X) is the amperage 3=30, 6=60, 1=100, 2=200 & 4=400.
Boldface figures are for voltage assignment; for different ratings see following pages.
Control contacts for plugs/receptacles: Use “K” where noted.
Ex: DS3104MR00K
“F” Flap Cap style shown. “S” Screw Cover option also available.
ex: “DF_ _ _ _” vs. “DS_ _ _ _”.
400 AMP plugs and connectors are supplied with cast aluminum handles.
Maximum Terminal Wire Size:
Rating Max.Conductor Size AWG Entrance Dia.
30 #8 AWG - 7 Strand or Flexible Conduit .187"
60 #4 AWG - 7 Strand or Flexible Conduit .302"
100 #0 AWG - 19 Strand or Flexible .386"
200 #4/0 AWG - 19 Strand or Flexible .625"
400 500MCM-37 Strand or Flexible .937"
Male Inlets: Mounted same as receptacle, all options
available. See pg. H29.
*
Ordering Information
H16 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 16
Cat. No. Cat. No. Cat. No. Cat. No.
DF3107FR0E0 DF3107FRAB0 DF3107FRA00 DF3107FR000
DF3207FR0E0 DF3207FRAB0 DF3207FRA00 DF3207FR000
DF3307FR0E0 DF3307FRAB0 DF3307FRA00 DF3307FR000
DF3404FR0E0 DF3404FRAB0 DF3404FRA00 DF3404FR000
DF3504FR0E0 DF3504FRAB0 DF3504FRA00 DF3504FR000
DF6207FR0E0 DF6207FRAB0 DF6207FRA00 DF6207FR000
DF6307FR0E0 DF6307FRAB0 DF6307FRA00 DF6307FR000
DF6404FR0E0 DF6404FRAB0 DF6404FRA00 DF6404FR000
DF6504FR0E0 DF6504FRAB0 DF6504FRA00 DF6504FR000
DF1207FR0E0 DF1207FRAB0 DF1207FRA00 DF1207FR000
DF1307FR0E0 DF1307FRAB0 DF1307FRA00 DF1307FR000
DF1404FR0E0 DF1404FRAB0 DF1404FRA00 DF1404FR000
DF1504FR0E0 DF1504FRAB0 DF1504FRA00 DF1504FR000
DF2304FRAB0 DF2304FRA00 DF2304FR000
DF2404FRAB0 DF2404FRA00 DF2404FR000
DF2504FRAB0 DF2504FRA00 DF2504FR000
DF4304FRAB0 DF4304FRA00 DF4304FR000
DF4404FRAB0 DF4404FRA00 DF4404FR000
DF4504FRAB0 DF4504FRA00 DF4504FR000
** Disconnect Service Ratings Available (Consult Factory)
** If receptacle is desired with a Straight Adapter instead of standard Angle Adapter, substitute “S” for
the “A” in the catalog number.
Boldface figures are for voltage assignment; for different ratings see following pages.
Receptacles furnished with flap cap also have screw thread to accept male collar on plug.
Catalog numbers shown are for flap cap receptacles, change “DF” to “DS” for
ordering screw cap.
Control contacts for plugs/receptacles: Use “K” where noted.
Ex: DS3104MR00K
“F” Flap Cap style shown. “S” Screw Cover option also available.
ex: “DF_ _ _ _” vs. “DS_ _ _ _”.
Receptacle with Angle
Receptacle with Angle Enclosure Adapter & Junction Box** Receptacle with Angle Adapter** Receptacle Only
MaxGard®Interconnection Systems
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Maximum Terminal Wire Size:
Rating Max.Conductor Size AWG Entrance Dia.
30 #8 AWG - 7 Strand or Flexible Conduit .187"
60 #4 AWG - 7 Strand or Flexible Conduit .302"
100 #0 AWG - 19 Strand or Flexible .386"
200 #4/0 AWG - 19 Strand or Flexible .625"
400 500MCM-37 Strand or Flexible .937"
Conduit entry furnished at location “B” unless otherwise specified.
30 Amp 1" NPT 200 Amp 3" NPT
60 Amp 1d" NPT 400 Amp 4" NPT
100 Amp 2" NPT
For adapters, junction boxes and accessories,
See pg. H29.
Ordering Information
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H17
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 17
Poles
Wires
30 Amp ▼▼
2P3W 125 DBRF310703000 DBRE310703000 DFRF31070 DSE3107FR0
2P3W 250 DBRF320703000 DBRE320703000 DFRF32070 DSE3207FR0
3P4W 3Ø250 DBRF330703000 DBRE330703000 DFRF33070 DSE3307FR0
3P4W 3Ø480 DBRF340403000 DBRE340403000 DFRF34040 DSE3404FR0
4P5W 277/480 DBRF350403000 DBRE350403000 DFRF35040 DSE3504FR0
60 Amp
2P3W 250 DBRF620706000 DBRE620706000 DFRF62070—
3P4W 125/250 DBRF630706000 DBRE630706000 DFRF63070—
3P4W 3Ø480 DBRF640406000 DBRE640406000 DFRF64040—
4P5W 277/480 DBRF650406000 DBRE650406000 DFRF65040
100 Amp
2P3W 250 DBRF120710000 DBRE120710000 DFRF12070—
3P4W 125/250 DBRF130710000 DBRE130710000 DFRF13070—
3P4W 3Ø480 DBRF140410000 DBRE140410000 DFRF14040—
4P5W 277/480 DBRF150410000 DBRE150410000 DFRF15040
200 Amp
3P4W 277/480 DBRF230420000 —
3P4W 3Ø480 DBRF240420000 —
4P5W 277/480 DBRF250420000 ——
400 Amp
3P4W 277/480 DBRF430740000 —
3P4W 3Ø480 DBRF440440000 —
4P5W 277/480 DBRF450440000 —
*
*
Maximum
600 VAC or
250 VDC Explosion-Proof
Interlocked Receptacle Interlocked Receptacle Fused Disconnect**
w/Circuit Breaker With Circuit Breaker Interlocked Receptacle Explosion Proof
Nema 4X Class I, Class II NEMA 12/3R Receptacle
Voltage Cat. No. Cat. No. Cat. No. Cat. No.
MaxGard®Interconnection Systems – Ordering Information
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
** Non-fused version available.
Replace DFRF with DNRF.
Boldface figures are for voltage
assignment; for different ratings
see following pages.
“F” Flap Cap style shown. “S”
Screw Cover option also available.
ex: “DF_ _ _ _” vs.
“DS_ _ _ _”.
B
A - std.
C
Interlocked Receptacles
Conduit Entries: NEMA 4X (at B or E)
Amp Std. NPT thread outlet Max
30 1d"2d"
60 1d"2d"
100 2" 2d"
E
Front
B - std.
Conduit Entries: NEMA XP (at A,B, or C)
Amp Std. NPT thread outlet Max
30 1.25" Consult
60 1.50" Technical
100 2.00" Services
Fused Disconnect DFRF – top entry only
☞ ☛ Notes to Catalog Numbers: Suffixes
Control Breaker Trip
Contacts Ratings
(position 12) (positions 9, 10, 11)
use “K” example: 30 amp use 030
DBRF6104060K0 50 amp use 050
60 amp use 060
Shunt Trip Breaker
(position 13) Non-Auto Switch
add “Z” to above: (repl. “DBRF” with
DBRF6104060KZ “DSRF”)
H18 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 18
MaxGard®Interconnection Systems – Catalog Numbering System
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Receptacles, Plugs and Connectors.
D F 3 414 F R A B K
Ø = Standard configuration
K = 2 control contacts
B = Junction Box, E = Angle Enclosure
Ø = Without Adapter
A = Angle, S = Straight Adapter,
R = Receptacle or P = Plug
M = Male Pins, F = Female Sleeves (contacts)
Voltage Assignment Number
See page H20 (voltage selection chart)
Amperage Rating
3 = 30A, 6 = 60A, 1 = 100A, 2 = 200A, 4 = 400A
F = Flap Cover or S = Screw Cover (screw collar for male plugs and male inlets)
D = Gated-Dead Front
}Ex: FP = Connector
MR = Motor Inlet
(Last 3 positions above:
Ø can appear in any position –
standard plugs, etc. will have a
ØØØ suffix. “DS2404MPØØØ”)
D S R E 6 414 060 K S
Ø = Standard Configuration
S = Auxiliary Switch,
Z = Shunt Trip,
Ø = Standard Configuration
K = 2 Control Contacts,
Breaker Rating code: (Pg. H18, Breaker
Rating Trip Charts)
*NAO = Non-Automatic Switch
Voltage Assignment Number (Pg. H20 Voltage
Selection Chart)
Amperage Rating
3 = 30A, 6 = 60A, 1 = 100A, 2 = 200A, 4 = 400A
E = Explosion-Proof or F = Flap Cap (weathertight)
or S = Screw Cap (watertight)
R = Receptacle
*S = Switch or B = Circuit Breaker
D = Gated-Dead Front
Interlocks (Standard or Explosion Proof)
*With S in position 2, position 9, 10 and 11 must be NAO.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H19
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 19
MaxGard®Interconnection Systems – Voltage Selection Chart
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Single Polarization/Multiple Service* Assigned Voltages and Wiring Systems
N-R1-G R1-S2-G N-R1-S2-G R1-S2-T3-G N-R1-S2-T3-G 2P+G(DC)
Voltage Voltage Voltage Voltage Voltage Voltage
Assign. Assign. Assign. Assign. Assign. Assign.
No. Voltage No. Voltage No. Voltage No. Voltage No. Voltage No. Voltage Index
101 220V-50Hz 201 380V-50Hz 301 220/380V-50Hz 401 380V-50Hz 501 220/380V-50Hz 01
103 127V-50Hz 203 220V-50Hz 303 220/127V-50Hz 403 220V-50Hz 503 220/127V-50Hz 03
104 277V-60Hz 204 480V-60Hz 304 277/480V-60Hz 404 3Ø480V-60Hz 504 3ØY277/480V/60Hz 04
105 250V-50Hz 205 440V-50Hz 305 250/440V-50Hz 405 3Ø440V-50Hz 505 3Ø250/440V-50Hz 05
107 125V-60Hz 207 250V-60Hz 307 125/250V-60Hz 407 3Ø250V-60Hz 507 3ØY125/250V-60Hz 07
108 220V-60Hz 208 380V-60Hz 308 220/380V-60Hz 408 3Ø380V-60Hz 508 3Ø220/380V-60Hz 08
109 100V-60Hz 209 220V-60Hz 309 100/220V-60Hz 409 3Ø220V-60Hz 509 3Ø100/220V-60Hz 09
111 115V-400Hz 211 220V-400Hz 311 220/115V-400Hz 411 220V-400Hz 511 220/115V-400Hz 11
——— —513 230V DC 613 250V DC 13
114 347V-60Hz 214 600V-60Hz 314 347/600V-60Hz 414 3Ø600V-60Hz 514 3ØY347/600V-60Hz 14
115 100V-50Hz 215 220V-50Hz 315 100/220V-50Hz 415 3Ø220V-50Hz 515 3Ø100/220V-50Hz 15
116 120V-60Hz 216 208V-60Hz 316 120/208V-60Hz 416 3Ø208V-60Hz 516 3ØY120/208V-60Hz 16
117 120V-400Hz 217 208V-400Hz 317 120/208V-400Hz 417 3Ø208V-400Hz 517 3Ø120/208V-400Hz 17
208V — 618 28VDC 18
150% reserved 20
221 440V-60Hz 321 250/440V-60Hz 421 3Ø440V-60Hz 521 3ØY250/440V-60Hz 21
250V 150% reserved 22
480V 150% reserved 23
600V 150% reserved 24
G
1N
G
1
2
G
1
2
G
3
N
G
1N
G
1N
2332
MaxGard receptacles and plugs may be furnished in any of
the above voltage and phasing systems.
To order any device in a voltage and phasing not shown in
the preceding catalog pages, substitute the Voltage
Assignment Number in the above chart for that portion of the
listed catalog number appearing in bold face type.
Example:
200 amp Weathertight Receptacle with Flap Cover, Angle
Adapter and Junction Box for 3Ø 480 volt (3 pole and
ground) is DF2404FRAB0.
To change to 3Ø 208 volt, the catalog number becomes
DF2416FRAB0.
Note: All devices may be furnished with two control
contacts. Add “K” to the end of the catalog number, in place
of last position Ø.
*Dual Voltage or Multiple Service Applications:
(for any given polarization number)
Example: A factory installation may consist
of all receptacles specified and wired at polarization “507”.
This is a 3ph.Y–125/250V–60Hz supply. However, all circuit
requirements “below” (507) can also be met; for instance a
“207” plug will draw phasing for 250V-60Hz operation of
equipment as well, while another “.507” receptacle supplies
power for a 3 phase motor installation. See chart above.
For Polarizations at 45, 90, 150, 300, 600A ratings
Consult Technical Services.
H20 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 20
MaxGard®Interconnection Systems – Custom Products
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Portable Power Distribution Centers
MaxGard®portable power centers provide power to temporary, mobile or
permanent applications that may require utilizing transformers, branch
circuit or outlet breakers, multiple voltage outputs and even different power
outlet types in a single enclosure. The resulting package powers welding
machines, compressors, heaters, lighting, blowers, thermal containers or
any other distributed power need.
Panels can be completely customized to various output, input, protection,
construction and cabling requirements, including interlocked switched or
standard outlets in any polarization. For instance, 480 volt 3-phase
industrial power can be supplied along with a 60Hz standard 125 volt
output in the same case; or with convenience outlets from another
Russellstoll line for electric hand tools in the full range of amperages
available. Even in the same amperage rating, plugs are non-
interchangeable due to single rating polarizations. It’s a flexible, economical
system that can eliminate 50% or more of temporary wiring requirements.
Safety
• All MaxGard receptacles in power centers are gated dead-front types,
either interlocked with a circuit breaker, separate fused switch or discrete
main breaker.
• No plug can be inserted or removed from interlocked receptacles unless
the circuit breaker or switch is in the off position.
• Interlocks cannot be turned ON until a plug is fully inserted.
• All circuit breakers trip free of interlock handles.
Durability
• Power centers are protected from rough handling and severe weather at
the dock, construction site, or other installations by a rugged steel frame
and enclosure.
• Final design and finishes are to customer spec.
Performance
• MaxGard Portable power centers are available with power ratings from 30
to 400 amperes at 120 to 600 volts AC.
• Combinations are available to meet many job conditions.
• All power centers can be supplied with provisions for male inlet,
receptacle or direct cable feeds.
• “Customization is Standard.”
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H21
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 21
H
Russellstoll ®
Russellstoll Appleton
DBRE/DSRE Crouse Hinds EBR Series
Feature Series EPC Series (w/FB breaker)
Waterproof (DurORing) O-ring sealing Yes No No
Available to 5 wire (4 pole, 5 wire) thru 100 Amp Yes No No
Gated Dead Front Yes No No
Center Ground Sleeve Contact Yes No No
24 Single Rated Factory Polarizations Yes No No
Class I, Div. 1, Groups B, C, D Yes Yes Yes
Class II, Div. 1, Groups F&G Yes Yes Yes*
Meets Coast Guard (was CG259) Approvals Yes No No
* Group F excepting electrically conductive dusts
Russellstoll Crouse Hinds Appleton
Feature MaxGard®Arktite®Powertite®
30 to 400 amps, + 150% ratings Yes Yes No
Center Ground Contact Yes No No
24 Single Rated Factory Polarizations Yes No No
Gated Dead Front Construction Yes No No
Two Optional Control Contacts Yes No No
Marine Grade CDA485 Brass Pins/Sleeves Yes No No
(200-400 amp silver-plated)
“O” Rings/Environmental Separation, Full Line Yes No No
Available to 5 wire (4 pole, 5 wire) Yes 30 & 60 amp only No
Complete line epoxy powder coated — standard Yes No Some
MaxGard®Interconnection Systems – Competitive Checklist
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Receptacles, Plugs and Connectors
Interlocked XP Receptacles
H22 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 22
H
Russellstoll ®
MaxGard®Interconnection Systems – Dimensions
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Male Plug Connector Male Inlet
Receptacle with
Angle Enclosure
Receptacle w/ Angle Adapter
& DJB Junction Box
Receptacle with Angle
Adapter
Amp A B
30 4f" 7g"
60 5d" 9a"
100 6d" 10a"
200 9" 13f"
400 12e" 17e"
Amp A B
30 8f" 5a"
60 10" 5c"
100 11a" 5c"
200 15" 9d"
400 19a" 10f"
Amp A B C
30 2g" 2d" 5d"
60 3c" 2d" 5d"
100 3c" 2d" 5d"
200 5b" 3d" 9b"
400 3e" 4c" 9b"
Amp A B C
30 9a" 3" 9e"
60 10d" 3" 9f"
100 10f" 3f" 10"
200 15f" 6e" 14e"
400 25b" 12" 20f"
Amp A B C
30 6c" 3a" 9g"
60 7a" 4" 11a"
100 7d" 4" 11c"
200 ——
400 ——
Amp A B
30 6a" 9e"
60 7d" 9f"
100 7" 10"
200 9d" 14f"
400 13b" 20f"
(Flap covers shown – screw covers available. On all, screw covers have nominal effect on outside dimensions.)
H24 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 24
H
Russellstoll ®
MaxGard®Interconnection Systems – Dimensions
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Receptacle Only Interlocked Receptacle w/
Circuit Breaker NEMA 4X
Explosion-Proof, Circuit-
Breaker Interlocked Receptacle
Fused Disconnect Interlocked
Receptacle NEMA 3R/12
Explosion Proof Non-Interlocked
Receptacle
Amp A B
30 2g" 4d"
60 3c" 5a"
100 3e" 5c"
200 5b" 6e"
400 7" 7a"
Amp A B C D E F G
30 c" 8f" 6d" 1d" 16b" 15a" 3a"
60 c" 8f" 6d" 1d" 16b" 15a" 3a"
100 c" 8f" 6d" 1d" 17f" 16e" 3a"
200 l" 12b" 9" 2d" 26b" 24f" 5"
400 l" 15d" 12" 3" 30d" 29" 6"
Amp A B C D E
30 8f" 7d" d" 14f" 20"
60 8f" 7d" d" 14f" 20"
100 8f" 7d" d" 14f" 20"
200 N/A N/A N/A N/A N/A
400 N/A N/A N/A N/A N/A
Amp A B C D E F
30 9d" f" 2545" 25" 22f" 30"
60 9d" f" 2545" 25" 22f" 30"
100 9d" f" 2545" 25" 22f" 30"
200 N/A N/A N/A N/A N/A N/A
400 N/A N/A N/A N/A N/A N/A
Fasteners Screws
2 Places
Holes for Padlock
2 Places
CD
B
A
F
E
7.50
2.18
ON
OFF
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H25
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 25
H
Russellstoll ®
30 Amp 60 Amp 100 Amp 200 Amp 400 Amp
Description Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
Fused Disconnect Interlocked Receptacle
with Safety Switch
30-100A
1 NO - 1 NC CONTACT F34757 F34757 F34757 N/A N/A
2 NO - 2 NC CONTACT F34758 F34756B N/A N/A N/A
Copper Body lugs - 6 lugs per kit F34756A F34756B F34756C N/A N/A
Type R Fuse Clips - 3 per kit F34755A F34755B F34755C N/A N/A
Neutral Block F34754A F34754B F34754B N/A N/A
MaxGard®Interconnection Systems – Accessories
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Circuit Breakers for NEMA 4X Interlocked Receptacles
High Interrupt breakers may be furnished at additional cost.
High Interrupt
Standard Circuit Breakers Circuit Breakers (optional)
Max. Max.
Interlock Volts Amperes Volts Amperes
240 AC 20,000 Asym., 18,000 Sym. 240 AC 75,000 Asym., 65,000 Sym.
30, 60 277 AC 15,000 Asym., 14,000 Sym. 277 AC 30,000 Asym., 25,000 Sym.
& 100 480 AC 15,000 Asym., 14,000 Sym. 600 AC 20,000 Asym., 18,000 Sym.
Amp 600 AC 15,000 Asym., 14,000 Sym. 600 AC 20,000 Asym., 18,000 Sym.
250 DC 10,000 Amperes 250 DC 10,000 Amperes
240 AC 75,000 Asym., 65,000
200 480 AC 30,000 Asym., 25,000 Sym.
Amp 600 AC 20,000 Asym., 18,000 Sym. N/A
250 DC 10,000 Amperes
240 AC 50,000 Asym., 42,000 Sym. 240 AC 75,000 Asym., 65,000 Sym.
400 277 AC 35,000 Asym., 30,000 Sym. 480 AC 40,000 Asym., 35,000 Sym.
Amp 480 AC 25,000 Asym., 22,000 Sym. 600 AC 30,000 Asym., 25,000 Sym.
250 DC 10,000 Amperes 250 DC 20,000 Amperes
For Interlocked NEMA 12/3R Receptacles
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H23
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 23
H
Russellstoll ®
MaxGard®Interconnection Systems – Accessories
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Cable Bushings
For MaxGard Plugs & Connectors
To order non-standard bushing, add cable bushing number to end of catalog number. This is furnished at no additional cost at
time of order. Ex: DF2504FP000/DF2032.
Shaded areas show Cable Bushings provided with strain relief neck; larger bushings are collar style.
Hole Diameter Size 3 Size 6 Size 10 Size 20 Size 40
for Cable 30 Amp 60 Amp 100 Amp 200 Amp 400 Amp
.625" JG63
.750" JG64 JG104
.875" JG65 Std. 2P3W JG105
1.000" JG66 Std. 2P3W JG106 DF1020 DF2020
1.188" JG67 Std. 3P4W JG107 Std. 2P3W DF1022 DF2022
1.313" JG108 Std. 3P4W DF1024 DF2024
1.375" JG69
1.500" JG610 JG1010 Std. 4P5W DF1026 DF2026
1.625"
1.688" JG1011 DF1027 Std. 2P3W DF2027
1.813" DF1029 Std. 3P4W DF2029
1.875" JG1013 DF1030 DF2032 Std. 2P3W
2.000" DF1032 Std. 4P5W
2.125" DF2034 Std. 3P4W
2.250" DF2036 Std. 4P5W
2.500" DF2040
2.625" DF4042
2.750" DF4044
3.000" DF4048 Std. 3P4W
3.250" DF4054 Std. 4P5W
Standard Cable Bushings:
Notes:
When ordering, select bushing size slightly larger than your cable O.D. for best fit.
Material – Neoprene
Identification
Letter Inside
Hole
Size No. 3 and 6
Size No. 10, 20 & 40
H26 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 26
H
Russellstoll ®
MaxGard®Interconnection Systems – Accessories
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Adapters for Conduit and Fittings
Adapters are tapped NPT standard pipe thread to accommodate rigid conduit or
standard connectors for armored and non-metallic cable or flexible conduit.
JPA xx
Conduit
Adapter
Replacement Flap Covers & Screw Covers
For Connectors, Receptacles & Interlocks
Description Amperage Cat. No.
30 DFC3
60 DFC6
Flap Cover Assembly 100 DFC10
(Weathertight) 200 DFC20
400 DFC40
30 DSC3
Screw Cap and STS - Lanyard 60 DSC6
Assembly 100 DSC10
(Watertight) 200 DSC20
400 DSC40
For Plug or Connector Sizes
30 Amp Tapped Hole 60 Amp Tapped Hole 100 Amp Tapped Hole 200 Amp Tapped Hole 400 Amp Tapped Hole
Cat. No. Size NPT Cat. No. Size NPT Cat. No. Size NPT Cat. No. Size NPT Cat. No. Size NPT
JPA62 f" JPA104 1b" DFA14 1b" DFA25 1d" DFA46 2"
JPA63 1" JPA105 1d" DFA15 1d" DFA26 2" DFA47 2d"
JPA64 1b" JPA 106 2" DFA16 2" DFA27 2d" DFA48 3"
JPA65 1d"
Notes:
Material – cast aluminum, corrosion-resistant copper-free alloy, electrostatic epoxy coated. Furnished complete with gasket and screws.
To specify standard plugs or connectors equipped with one of the above adapters, add the catalog number of the adapter selected to the catalog number of the plug or connector.
Complete list price is the list price of the device plus list price of the adapter.
Example: Cat. No. DS3107MP000 with adapter tapped 1-inch would be Cat. No. DS3107MP000/JPA63.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H27
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 27
H
Russellstoll ®
MaxGard®Interconnection Systems – Accessories
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
Replacement Interiors
For Receptacles, Connectors, Plugs & Male Inlets
Corresponding Male Corresponding Female
Voltage
Interior Assembly Interior Assembly
Rating Polarization Plug/Inlet Male Interior Connector/Receptacle Female Interior
2P3W 125VAC DS3107MP000 DFPU3107 DF3107FP000 DFRU3107
2P3W 250VAC DS3207MP000 DFPU3207 DF3207FP000 DFRU3207
30A 3P4W 125/250 VAC DS3307MP000 DFPU3307 DF3307FP000 DFRU3307
3P4W 3 ph 480VAC DS3404MP000 DFPU3404 DF3404FP000 DFRU3404
4P5W 277/480VAC DS3504MP000 DFPU3504 DF3504FP000 DFRU3504
2P3W 250VAC DS6207MP000 DFPU6207 DF6207FP000 DFRU6207
60A 3P4W 125/250 VAC DS6307MP000 DFPU6307 DF6307FP000 DFRU6307
3P4W 3 ph 480VAC DS6404MP000 DFPU6404 DF6404FP000 DFRU6404
4P5W 277/480VAC DS6504MP000 DFPU6504 DF6504FP000 DFRU6504
2P3W 250VAC DS1207MP000 DFPU1207 DF1207FP000 DFRU1207
100A 3P4W 125/250 VAC DS1307MP000 DFPU1307 DF1307FP000 DFRU1307
3P4W 3 ph 480VAC DS1404MP000 DFPU1404 DF1404FP000 DFRU1404
4P5W 277/480VAC DS1504MP000 DFPU1504 DF1504FP000 DFRU1504
3P4W 277/480VAC DS2304MP000 DFPU2304 DF2304FP000 DFRU2304
200A 3P4W 3 ph 480VAC DS2404MP000 DFPU2404 DF2404FP000 DFRU2404
4P5W 277/480VAC DS2504MP000 DFPU2504 DF2504FP000 DFRU2504
3P4W 277/480VAC DS4304MP000 DFPU4304 DF4304FP000 DFRU4304
400A 3P4W 3 ph 480VAC DS4404MP000 DFPU4404 DF4404FP000 DFRU4404
4P5W 277/480VAC DS4504MP000 DFPU4504 DF4504FP000 DFRU4504
Note:
For other interiors not shown, use same polarization index as plug, connector,
etc. Ex: DS6416MP000 plug uses DFPU6416 interior.
H28 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 28
H
Russellstoll ®
30 Amp 60 Amp 100 Amp 200 Amp 400 Amp
Description Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
Cup Caps
For watertight plugs/inlets. Cup caps are used
where portable equipment is on a standby
basis and plugs are not in use. To effectively
DS3CC DS6CC DS1CC DS2CC DS4CC
protect insulation and contacts from excessive
moisture, dirt, dust and corrosion.
Material – cast aluminum, corrosion-resistant
copper-free alloy, electrostatic epoxy coated
with steel braid cable attached.
Adapter Flush Frames – Single Gang
JFA6 JFA10 JFA10 JFA20 Consult
Provide suitable means for mounting box Factory
covers of junction box receptacles flush in
a wall.
Adapters for Conduit Box Receptacles
Adapters to fit existing boxes and for
special mounting requirements can also JAA6-AB6 JAA10 DAA10 DAA20
be furnished. Consult Factory. — — — — DAA40
20° Vertical Angle Adapter JAA6-45 JAA10-45
30° Vertical Angle Adapter JRA6-AB6 JRA10 DRA10 DRA20 DRA40
45° Vertical Angle Adapter
Straight Adapter
Junction Box - Single Gang JB6-1 JB10-B150 JB10-B200 DJB20 DJB40
Angle Enclosure JE6 JE10 JE10M
MACK Adapter Plates
Allows mounting of MaxGard receptacles to
competitive existing back boxes. This involves
removing the existing non-hazardous location DCCA3 DCCA6 DCCA10 DCCA20
receptacle from back box, inserting adapter
plate and installing MaxGard receptacle.
Adapter plates are available for competitor’s
boxes including Hubbel, Killark, Appleton
& Crouse-Hinds.
Russellstoll Adapter Plates
Adapt MaxGard receptacles to existing DRCA3 DRCA6 DRCA10 DRCA20 N/A
J-Line, Angle Type and Heavy Service
Ever-Lok back boxes.
Note: For 8X … Cat. #s, contact Customer Service. These are additional accessory items.
MaxGard®Interconnection Systems – Accessories
30-400/600 Amp Plugs, Connectors, Receptacles, Inlets and Interlocked Receptacles
For Receptacles
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H29
Heavy Industrial/ Marine
412031.H01 MAX 3/5 3/14/03 6:40 PM Page 29
J-Line Interconnection Systems
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
Design Features
Russellstoll®J-Line Load Breaking Plugs, Connectors and Receptacles
1. Circuit interrupting rated safety.
2. Cast aluminum, corrosion resistant copper free
alloy housings and enclosures provide light weight
and maximum corrosion resistance, along with
electrostatic epoxy powder coat finish.
3. Quick conversion between weathertight flap cover
and watertight screw cap assemblies. Basic
receptacle housing accommodates both covers
and is the basic component of all complete units.
All watertight configured plugs may be used
interchangeably.
4. Two grounding arrangements
(Style No. 1 and Style No. 2).
5. Four Complete J-Lines
30, 60, 100 and 200 Amps, 600 Volts, A.C. 250
Volts, D.C. (plus 150A/270A specials)
6. Flap cover can be rotated and locked in any
convenient position.
7. Pressure type solderless wiring terminals.
8. Silver plated contacts.
9. One-piece interior assemblies.
Interchangeable from regular to reverse service in
the field with a screwdriver.
10. Wiring space
Ample for maximum requirements.
11. Cable Clamps
Adjustable, for maximum range of cable size. Oil
resistant neoprene strain-relief bushing
compresses around cable tightly, prevents entry of
dust and moisture.
12. Polarization
Provides positive non-interchangeability for
different electrical systems.
13. Reversed contacts flexibility male-female reversed
installation within any housing.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H31
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 31
Devices offer standard and custom polarization for total operator safety so that plugs
will fit only into receptacles or connectors having the same electrical/specification
characteristics.
Visual means of aligning units for a specific, positive polarization are
provided:
• Button inside of receptacle housing mates to groove on plug shroud.
• Smaller primary guides also assist positive part-part
mating.
• External I.D. of 1 of 8 polarization indexes visible.
• Different polarizations assigned to voltages
can’t mate – a safer system!
J-Line Interconnection Systems
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
Conversion To Weathertight and Watertight Types
Weathertight
J-Line
with flap
cover assembly
Watertight
J-Line
With Screw Cap
Polarization
Substitution of either the flap cover assembly or the screw
cap assembly on the housing of the basic receptacle
permits quick and easy conversion between the weathertight
and watertight types. Only a small screwdriver is needed to
change in the field.
The basic receptacle housing is constructed with a threaded
end to accommodate a screw cap or the collar nut of a
watertight plug. A special groove above the threads
accommodates the flap cover assembly. The flap cover
assembly may be rotated around this grooved shell and the
set-screw locked in any convenient position.
The watertight plug, with its collar screwed firmly to the
basic receptacle shell, forms a completely watertight
connection on either type of receptacle assembly.
These conversion features also permit the use of flap cover
or screw cap on connector housings.
H32 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 32
All J-Line plugs, receptacles and connectors can be
furnished for Reverse Service – male (plug) interiors in the
receptacles and female (receptacle) interiors in the plugs.
When ordering reverse service add a final suffix “R” to the
complete catalog number. Price on application.
Example: JRFA334HR
J-Line receptacle and plug interior assemblies of the same
amperage may be quickly interchanged from regular to
reverse service (or vice versa) in the field. A screwdriver is
the only tool required.
Example: Panel mounted low profile receptacles with male
interiors act as Male Inlets in remote equipment;
receive power from “Female Plugs”. (Cup cap also
recommended).
Reverse Service
Note the complete interior assemblies have now
been interchanged so that the male (plug) interior
assembly is positioned in the receptacle housing
and the female (receptacle) interior assembly is
positioned in the plug housing.
Regular Service
Interior assemblies placed in normal,
standard positions – female interior
assembly is positioned in the
receptacle housing and the male
interior assembly is positioned
in the plug housing.
Reversed Contacts Service
For all Weathertight and Watertight types
J-Line Interconnection Systems
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H33
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 33
Grounding Data
J-Line Interconnection Systems
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
Portable cord
3 conductors + G
Grounding thru
plug & receptacle
housing
Grounding
thru conduit
system only
Equipment ground
connected to
plug shell
Plug Receptacle
Portable cord
4 conductors
Grounding thru
plug & receptacle
housing
Equipment ground
connected to extra
pole and plug shell
Plug Receptacle
Factory installed
jumper
4th grounding
wire – if desired
Style 1 – Typical 3P3W Plug & Receptacle Style 2 – Typical 3P4W Plug & Receptacle
STYLE 1
4P4W (or 3P3W)
Through Metal Housings of Plug and Receptacle
In this system shown above, the equipment grounding
conductor in the flexible cable is electrically connected
directly to the plug or cable connector housing by a suitable
terminal. The receptacle is grounded by being part of a
grounded conduit system.
When inserted, the plug housing makes contact with the
grounded receptacle or connector housing by means of the
receptacle ground spring before the current-carrying
contacts engage. On withdrawal, it remains in contact until
after the current-carrying contacts disengage.
STYLE 2
3P4W (or 2P3W)
Through a Separate Grounding Pole in Plug and
Receptacle
In this system shown above, the equipment grounding
conductor in the flexible cable is electrically connected to the
equipment grounding pole in the plug or cable connector
interior. The grounding pole of the receptacle interior is elec-
trically connected by a spring strap jumper to the receptacle
housing which itself is grounded by being part of the ground
spring of the receptacle or connector housing as described in
system number one.
The grounding contact in a type 2 receptacle is longer than
the current-carrying contacts so that the ground connection
makes first and breaks last.
Corrosive Locations: The National Electrical Code requires
that under conditions favorable to corrosion, the grounding
conductor for enclosures and equipment be of copper or
other corrosion-resistant material. In alternating current
systems, this necessitates running another conductor back
to the common grounding electrode. This may be run
through the conduit containing the circuit conductors. At the
receptacle, this grounding conductor should be connected
to the extra (grounding) pole by the pressure connector
provided for that purpose. Where such an extra grounding
conductor is required, Style 2 receptacles should be used.
Effective grounding of portable electric equipment is
necessary to protect operators from electric shock. The
National Electrical Code requires that in most cases
exposed non-current-carrying metal parts of portable
equipment shall be grounded if operated at more than 150
volts to ground. Grounding must be used in other than
residential occupancies when used in damp or wet
locations, or by persons standing on the ground or on metal
floors or working inside of metal tanks or boilers, except
where supplied through an insulating transformer with
ungrounded secondary of not over 50 volts. Plugs and
receptacles provide for grounding of portable equipment
in either of two ways:
H34 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 34
Mounting Current Rating
Style To Order Use: 30 Amp 60 Amp 100/150 Amps 200/270 Amps
Standard Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle* Basic Receptacle*
Series +++++
JRFA/JRSA
Vertical or Square JB3 JB6 JB10 JB20
Mount Box 1" Std. Conduit Size 1d" Std. Conduit Size 2" Std. Conduit Size 3" Std. Conduit Size
+++++
Angle JAA3 (20°) JAA6-AB6 (20°) JAA10 (20°) JAA20 (20°)
Adapter or or or or
JAA3-45 (45°) JAA6-45 (45°) JAA10-45 (45°) JAA20-45 (45°)
Series Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle* Basic Receptacle*
JRFR/JRSR +++++
Straight
Vertical Mount JB3 JB6 JB10 JB20
Box 1" Std. Conduit Size 1d" Std. Conduit Size 2" Std. Conduit Size 3" Std. Conduit Size
+++++
Straight JRA3 JRA6-AB6 JRA10 JRA20
Adapter
Series Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle* Basic Receptacle*
JRFB/JRSB +++++
30° Angle JAAB3 JAAB6 JAAB10 JAAB20
Adapter
Series Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle*
JRFE/JRSE ++++N/A
Angle Enclosure JE3 JE6 JE10
1" Std. Conduit Size 1d" Std. Conduit Size 2" Std. Conduit Size
Series Receptacle Basic Receptacle*
JRFH/JRSH ++
Horizontal
Horizontal JB3 N/A N/A N/A
Mount Box 1" Std. Conduit Size
++
Angle Adapter JHA3 (20°)
* Select appropriate receptacle by rating, configuration and voltage on Page H37.
Note: JRXX 3rd letter denotes Flap (F) or Screw (S) Cover.
Ex: JRSA – Screw Cover
JRFA – Flap Cover
JRF – Flap Cover, Basic Receptacle
JRS – Screw Cover, Basic Receptacle
Receptacle Mounting Options – J-Line Construction
Progressive Assembly
J-Line Interconnection Systems
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H35
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 35
Plugs
Current Rating Weathertight / Watertight Configuration
❒ ▼
2P3W JPS323H __
Weathertight 3P3W* JPS333F
(Spring Hinged Flap Cover) 3P4W JPS334H
30 Amp 4P4W* JPS344F
2P3W JPS323H
Watertight 3P3W* JPS333F
(Screw Cover) 3P4W JPS334H
4P4W* JPS344F
2P3W JPS623H
Weathertight 3P3W* JPS633F
(Spring Hinged Flap Cover) 3P4W JPS634H
60 Amp 4P4W* JPS644F
2P3W JPS623H
Watertight 3P3W* JPS633F
(Screw Cover) 3P4W JPS634H
4P4W* JPS644F
2P3W JPS1023H
Weathertight 3P3W* JPS1033F
(Spring Hinged Flap Cover) 3P4W JPS1034H
100 Amp 4P4W* JPS1044F
(150 Amp)** 2P3W JPS1023H
Watertight 3P3W* JPS1033F
(Screw Cover) 3P4W JPS1034H
4P4W* JPS1044F
2P3W JPS2023H
Weathertight 3P3W* JPS2033F
(Spring Hinged Flap Cover) 3P4W JPS2034H
200 Amp 4P4W* JPS2044F
(270 Amp)** 2P3W JPS2023H
Watertight 3P3W* JPS2033F
(Screw Cover) 3P4W JPS2034H
4P4W* JPS2044F
For any J-Line catalog numbers not shown here, check page H35 for “Series”
information.
For special polarizations (suffixes) contact Technical Services.
(All plugs come with
watertight screw collar)
Max. 600VAC / 250VDC
* Housing Ground Only (Style 1 Grounding) see page H34.
+ Shown with 20° angle adapter. Can be furnished with 45° angle at same price. When ordering add
suffix -45 to catalog number.
** Special rated devices (not shown). Consult customer service for details.
Note: To order Reverse Service add a final suffix “R” to catalog number. Examples: JRFA334HR — a
receptacle housing with male interior.
Polarization index (std. shown) Consult Technical Services for more.
Flap Cover “F” noted. Screw Cover “S” also available
For Reversed Contacts, use “R” suffix to any catalog number.
Std. Cable Bushing
Current Rating Bushing I.D. Max. AWG Size
30 g" #6 - 7 strand or #8 flexible
60 1i" #4 - 7 strand or flexible
100 1d" #0 - 19 strand or #1 flexible
200 2" #4/0 - 19 strand or flexible
(see page H41 for other bushings)
J-Line Interconnection Systems – Ordering Information
30-270 Amp, (30, 60, 100 and 200 Amp Load Breaking
150 and 270 Amp Special Service) Maximum 600 VAC/250 VDC
Receptacles, Plugs, Connectors & Inlets
H36 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 36
Conduit Size: (Using JPA_ Series Conduit Adapters)
Current Rating Std. Size Max. Size
30 1" 1b"
60 1d" 1d"
100 2" 2"
200 3" 3"
* Smaller NPT openings available on request.
Cable Conduit Adapters: see page H42.
Panel Mount Basic Receptacle Standard Series*
❒ ▼ ❒ ▼ ❒ ▼
JCF323H __ JRFX323H __ JRF323H __ JRFA323H __
JCF333F JRFX333F JRF333F JRFA333F
JCF334H JRFX334H JRF334H JRFA334H
JCF344F JRFX344F JRF344F JRFA344F
JCS323H JRSX323H JRS323H JRSA323H
JCS333F JRSX333F JRS333F JRSA333F
JCS334H JRSX334H JRS334H JRSA334H
JCS344F JRSX344F JRS344F JRSA344F
JCF623H JRFX623H JRF623H JRFA623H
JCF633F JRFX633F JRF633F JRFA633F
JCF634H JRFX634H JRF634H JRFA634H
JCF644F JRFX644F JRF644F JRFA644F
JCS623H JRSX623H JRS623H JRSA623H
JCS633F JRSX633F JRS633F JRSA633F
JCS634H JRSX634H JRS634H JRSA634H
JCS644F JRSX644F JRS644F JRSA644F
JCF1023H JRFX1023H JRF1023H JRFA1023H
JCF1033F JRFX1033F JRF1033F JRFA1033F
JCF1034H JRFX1034H JRF1034H JRFA1034H
JCF1044F JRFX1044F JRF1044F JRFA1044F
JCS1023H JRSX1023H JRS1023H JRSA1023H
JCS1033F JRSX1033F JRS1033F JRSA1033F
JCS1034H JRSX1034H JRS1034H JRSA1034H
JCS1044F JRSX1044F JRS1044F JRSA1044F
JCF2023H JRFX2023H JRF2023H JRFA2023H
JCF2033F JRFX2033F JRF2033F JRFA2033F
JCF2034H JRFX2034H JRF2034H JRFA2034H
JCF2044F JRFX2044F JRF2044F JRFA2044F
JCS2023H JRSX2023H JRS2023H JRSA2023H
JCS2033F JRSX2033F JRS2033F JRSA2033F
JCS2034H JRSX2034H JRS2034H JRSA2034H
JCS2044F JRSX2044F JRS2044F JRSA2044F
Connectors Receptacles
Conduit Entry Location: Standard Series
J-Line Interconnection Systems – Ordering Information
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
30 & 60 Amp 100 & 200 Amp
B Std.
AC
D
B Std.
AC
D
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H37
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:42 PM Page 37
Dimensions for 2, 3 or 4 wire Units
Weathertight Watertight Weathertight Watertight
Amp Z Y X S SW R RW V U T
30 2f" 2f" 1 3c" 3f" 4b" 3" 2b" 2b" b"
60 3d" 3d" 1b" 4e" 4f" 5" 3f" 2g" 2g" s"
100/150 4" 4" 1b" 5" 5b" 5b" 4a" 3c" 3c" s"
200/270 5e" 5e" 1f" 6a" 6c" 7a" 5f" 4g" 4g" X"
Plugs and Connectors
Dimensions for 2, 3 or 4 wire Weathertight and Watertight Units
Weathertight Watertight Weathertight Watertight
Amp A B C F FW R RW Y Z H
30 3" 2a" 7" 8a" 8c" 4b" 3" 2f" 2f" 1
60 3f" 2l" 8g" 10f" 10c" 5" 3f" 3d" 3d" 3c"
100/150 4a" 2m" 10b" 10d" 10g" 5b" 4a" 4" 4" 1g"
200/270 5f" 3n" 14e" 14g" 15c" 7a" 5f" 5e" 5e" 2d"
Weathertight
Female - Connector
Watertight
Watertight Male — Plug
Basic Receptacles
J-Line Interconnection Systems – Dimensions
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
H38 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:43 PM Page 38
Panel Mount Series Standard Series JRFA/JRSA Series JRFR/JRSR
Series JRFB/JRSB Series JRFE/JRSE Series JRFH/HRSH
Weathertight Panel
Amp Series Z Y X S SW R RW Q P V U T Opening
Panel Mount 3d" 3d" 2l" 1f" 2" 4b" 3" 2g" 2g" b" 2f"
Standard (20°) 4d" 3" 2a" 7" 6d" 6f" 6f" 2W" 3W" b"
30 JRFR/JRSR 4d" 3" 2a" 6a" 6d" 2W" 3W" b"
JRFB/JRSB 3a" 3a" 5f" 5f" 2b" 2b" b" 2b"
JRFE/JRSE 3d" 5b" 4e" 7a" 7a" 1b" 2c" 4 b"
JRFH/JRSH 3j" 4d" 2a" 7" 6d" 6e" 6e" 2W" 3W" b"
Panel Mount 4" 4" 3g" 1f" 2" 5" 3f" 3c" 3c" s" 3b"
Standard (20°) 5e" 4" 3" 9b" 8e" 8g" 9" 3m" 4m" X"
60 JRFR/JRSR 5e" 4" 3" 8c" 8d" 3m" 4n" X"
JRFB/JRSB 3i" 3e" 7c" 7c" 2i" 2e" s" 2d"
JRFE/JRSE 4b" 6c" 5f" 9f" 9d" 1l" 3W" 3a" 4d" s"
Panel Mount 4b" 4b" 4k" 1f" 2" 5b" 4a" 3e" 3e" s" 3d"
Standard (20°) 5d" 5d" 3d" 10d" 9g" 9g" 9f" 6f" 4b" X"
100/150 JRFR/JRSR 5d" 5d" 3d" 11b" 11g" 6f" 4b" X"
JRFB/JRSB 3i" 3e" 8b" 8b" 2i" 2e" s"
Panel Mount 6" 6" 5g" 2" 2d" 7a" 5f" 5b" 5b" X" 5a"
Standard (20°) 8j" 8j" 6j" 15g" 15e" 12W" 12j" 9e" 7a" c"
200/270 JRFR/JRSR 8j" 8j" 6j" 15" 15d" 9e" 7a" c"
JRFB/JRSB 4" 4" 12b" 12b" 2f" 2f" X"
Note: U = horizontal mounting hole centers; V = vertical mounting hole centers
J-Line Interconnection Systems – Dimensions
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H39
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:43 PM Page 39
Amperes Cat. No.
30 F30717A
60 F30718A
100 F30814A
200 F30815A
Replacement Interiors
For Receptacles, Connectors, Plugs & Male Inlets
Female Interiors: Receptacles & Connectors Male Interiors: Plug & Male Inlets
Poles/Wires 30 Amp 60 Amp 100/150 Amp 200/270 Amp 30 Amp 60 Amp 100/150 Amp 200/270 Amp
+ 2P2W JRU322 JRU622 JRU1022 JRU2022 JPU322 JPU622 JPU1022 JPU2022
2P3W JRU323 JRU623 JRU1023 JRU2023 JPU323 JPU623 JPU1023 JPU2023
* 3P3W JRU333 JRU633 JRU1033 JRU2033 JPU333 JPU633 JPU1033 JPU2033
3P4W JRU334 JRU634 JRU1034 JRU2034 JPU334 JPU634 JPU1034 JPU2034
* 4P4W JRU344 JRU644 JRU1044 JRU2044 JPU344 JPU644 JPU1044 JPU2044
*Includes equipment grounding lug for attachment to enclosure.
+For replacement only – includes equipment grounding lug.
Material – Molded composition with silvered copper contacts.
Cup Caps
For Watertight (Series JPS) Plugs – Standard or Reverse Service
Cup Caps are used:
* Where portable equipment is on a standby basis and plugs are not in use.
* To effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion.
Material – cast aluminum, corrosion-resistant copper-free alloy, electrostatic epoxy coated with steel braid cable attached.
J-Line Interconnection Systems – Accessories
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
H40 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:43 PM Page 40
Cable Bushings
For J-Line Plugs and Connectors
Boxed catalog numbers are standard bushing sizes. To order non-standard bushing, specify as follows:
example JPS634H/JG65
Hole Diameter
for Cable 30 Amp 60 Amp 100/150 Amp 200/270 Amp
.375"JG31
.500"JG32
.563"JG325
.594"JG32B
.625"JG33 JG63
.750"JG34 JG64 JG104
.781"JG341
.875"JG35 JG65 JG105
.938"JG355
1.000"JG36* JG66 JG106 JG206
1.125"JG361*
1.188"JG67 JG107 JG207
1.313"JG108 JG208
1.375"JG69*
1.500"JG610* JG1010 JG2010
1.688"JG1011 JG2011
1.813"JG2012
1.875"JG1013*
2.000"JG2014
2.125"JG2015
2.500"JG2016*
Notes:
Boxed numbers denote standard bushing size supplied.
When ordering, select bushing size slightly larger than your cable O.D. for best fit.
Material – Neoprene
Identification
Letter Inside
Hole
Size No. 3 – 6 – 10 and 20
Size No. 3 – 6 – 10 and 20
Standard Cable Bushings: * Oversize Cable Bushings:
J-Line Interconnection Systems – Accessories
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H41
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:43 PM Page 41
Adapters for Conduit and Fittings
For use on J-Line Plugs and Connectors
Adapters are tapped NPT standard pipe thread to accommodate
rigid conduit or standard connectors for armored and non-metallic
cable or flexible conduit.
Notes:
Material – cast aluminum, corrosion-resistant copper-free alloy, electrostatic
epoxy coated. Furnished complete with gasket and screws.
*JPA65 @ 1d" also available.
To specify standard plugs or connectors equipped with one of the above adapters, add the
catalog number of the adapter selected to the catalog number of the plug or connector.
Complete list price is the list price of the device plus list price of the adapter.
Example: Cat. No. JPS634H with adapter tapped
1-inch would be Cat. No. JPS634H/JPA63.
Description Amperage Cat. No.
30 JFC3
Flap Cover Assembly 60 JFC6
(Weathertight) 100/150 JFC10
200/270 JFC20
Screw Cap and 30 JSC3
Braid Cable 60 JSC6
Assembly 100/150 JSC10
(Watertight) 200/270 JSC20
JPA 64 Conduit Adapter
(replaces cable gland assembly)
Covers
For Connectors & Receptacles
®
E2630 CSA C22.2-182
J-Line Interconnection Systems – Accessories
30-200/270 Amp, (30-200A Load Breaking) Maximum 600 VAC/250 VDC
Load Breaking Receptacles, Plugs, Connectors & Inlets
Plug or Connector Sizes
30 Amp Tapped Hole 60 Amp Tapped Hole 100/150 Amp Tapped Hole 200/270 Amp Tapped Hole
Cat. No. Size NPT Cat. No. Size NPT Cat. No. Size NPT Cat. No. Size NPT
JPA31 d" JPA62 f" JPA104 1b" JPA205 1d"
JPA32 f" JPA63 1" JPA105 1d" JPA206 2"
JPA33 1" JPA64 1b"* JPA106 2" JPA207 2d"
H42 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Heavy Industrial/ Marine
H
Russellstoll ®
412031.H02 JLINE 3/5 3/14/03 6:43 PM Page 42
The toughest design and
construction in thermoplastic safety,
durability and performance, in UL94-
V0 flame rated DuraV material. With
DurOring sealed pins, sleeves and
interiors, watertight even unmated. A
30 & 50A unique Circuit Breaker
Interlock line in DuraV is the best
choice for 5 standard voltage
polarization options through 600VAC
(Interlock to 480VAC).
Rough service users can specify the
FS/FD in aluminum or brass for
marine duty. In 20 and 30A ratings,
many installations can also mate to
DuraGard units. Switched or Circuit
Breaker Interlocks are also available
in brass or aluminum. Our large
installed base can be supported with
many construction & product options.
USCG Accepted 20-50A
convenience Interlocked
Receptacles accept FS/FD and
DuraGard plugs. Built for rough
service installations in aluminum or
brass, in Switched or Circuit Breaker
formats. Extremely heavy duty
designs for maximum durability.
Thermoplastic International standard
IEC 309-2 or CEE-17 connector
usage is growing; especially in OEM,
export and standard performance
applications. The “IP67” style is
watertight when mated and directly
interchangeable with other
manufacturers. International
designations shadow U.S. amperage
ratings: 20/(16), 30/(32), 60/(63) and
100/(125) Amps. IP67 devices have
screw collars or flap/screw covers,
with catalog number “W” suffixes.
DuraGard
to 4P4W
20 thru 50A
Washdown Industrial & Light Marine
FS/FD
to 3P4W
20 thru 30A
IEC (IP67)
to 4P5W
20 to 100A
Interlocked
Outlets
20 thru 50A
Defined
Marine
Lighting Connectors
Shore to Ship Power
Low Power Welding
Power Distribution Panels
Shipboard Power Outlets
Barge Power Connection
Construction & Agricultural
Generator Set Panels
Portable Tools & Equipment
Irrigation Systems Panels
Portable Lighting & Equipment
Food Processing, Brewery/
Beverage, Pulp & Paper,
Pharmaceuticals
Portable Building Power
Welding Outlets
Motor Power Connections
Lighting Systems
Machinery Interconnections
Process Control Power Systems
OEM’s
Export Machinery
Critical Power Connections
& Welding Systems
Transportable Equipment
Typical Application Groups
Russellstoll Line Selections for Outdoor (and Indoor) Applications
Any application where electrical connections need
protection from water and/or dust ingress to the contacts
or the wiring compartment.
Cable-to-connector sealing and device locking designs
are critical.
Thermoplastic connectors preferred: or aluminum
specified for rough services; (brass in many marine
installations).
H44 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 44
DuraGard®Features Make the Performance Difference.
Not just “watertight”; Waterproof for Washdown Duty: DurORingSealing
Specifically designed for wet environments with our unique DurORing™ sealing system.
Unit is watertight mated or unmated.
Eliminates need for costly “weather boots” or “adapters”.
Compact Size.
• “Lockout Ready” plugs have padlock access hole in front. (30/50A).
Durable, Tough & Flame Safety Rated Housings
• DuraVhousing material specially selected for hot or cold washdown duty.
Flame Safe UL94-V0 rated housings.
Superior Performance in Corrosive Environments.
High Visibility yellow housings.
Safe & Reliable Power Connections: Pin & Sleeve, Voltage Polarized
Long Life: Round, Self Cleaning, Constant Pressure Pin & Sleeve Contacts, of Solid CDA
360 brass for long reliable electrical life.
More Power, Operates Cooler: large circular electrical contact area allows more current
flow with lower temperature rise.
Ground Pin Keyed for Voltage Polarization (O-ring seal)
Easy To Wire
“No twistoff” Locking Plugs”: Integral Threaded Screw Collars and Compression type
Bushings make wiring a snap.
Fast Assembly and Wiring: “Drop-In” rear loaded interiors use no assembly screws, versus
3-5 or more with other connectors. 30/50A connectors use unique E-Z Titeexternal gland
lock screw, also.
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
The Next Generation: DuraGard®
Severe environments and high pressure washdown duty applications
require durable, waterproof and safe connections. Russellstoll takes design
reliability to new heights with Safety Gradestandards for truly waterproof
connectors. Many watertight specifications cover mated connections only.
DuraGard connectors are designed to be watertight mated or unmated,
thus offering the ultimate waterproof connection. DuraGard connectors are
also UL94-V0 flame rated for safety and utilize a durable, efficient pin &
sleeve contact design that is voltage polarized to meet NEC210-7 and
OSHA standards. DuraGard®… designed for maximum safety, durability
and performance.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H45
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 45
DuraGard®Pin and Sleeve Connections
Spring blade contact designs offer point contact only, with
minimal mechanical support in receptacles. Higher heat is
generated in use as contacts loosen with age and dirt
accumulation, resulting in failures. Exposed blade contacts
can easily be damaged. Contacts are both the electrical and
mechanical locking method.
Pin & Sleeve design allows higher current flow at cooler
temperatures due to large circular contact area. Sleeves act
as retainers for the pins making a reliable connection.
Shrouded pins & sleeves are protected from damage and
inadvertent access. Locking housing screw collars provide
for a reliable, long lasting connection, with electrical contacts
separate.
The Water Spray Test
1000 PSI water spray was directly applied at the face
of DuraGard receptacles. No damage occurred, and
no water penetrated the housing or cord seal.
DuraGard plugs, connectors and receptacles are
designed to withstand water spray test at 1000 PSI.
No extra cost boots or adapters required.
DuraGard: Designed For the Toughest Washdown Applications
Pulp & Paper Pharmaceutical ManufacturingFood Processing Beverage & Bottling
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
Pin & Sleeve
Bladed Plug & Receptacle Pin & Sleeve Connector & Plug
Spring Contacts
Blades
Shrouds
Sleeve Pin
Locking Screw Collar
Pin & Sleeve contact devices consist of round male pins
which are inserted into tubular female sleeves. Current flows
through a large pin-to-sleeve circular contact area. Because
current is not restricted through point contact only, higher
current flow and cooler operating temperatures are achieved
in a compact connection. Wiping action during insertion or
withdrawal provides positive self cleaning. Shrouded pins
and sleeves are protected from physical damage or casual
access and aid in polarization features of the line. The shroud
and screw collar completely lock plugs to receptacles or
connectors for a reliable connection. Step on the cord, kick or
drop a plug; your connection will remain tight. Pin & Sleeve
devices are the safety standard for high current applications
worldwide.
H46 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 46
20, 30 & 50 Amps, 600 VAC
20 Amp, 250 VDC
Safety Specified Voltage Connections:
• Safety Ground Makes First, Breaks Last.
• Voltage Polarized to Meet NEC210-7
and OSHA Standards.
High Reliability, High
Performance Connections:
• CDA 360 Solid Brass Pin &
Sleeve Contacts.
Long Lasting Self Cleaning
Connections:
• Full Round Pin & Sleeve Contacts.
Fast, Easy, Rear Load
Wiring & Assembly:
• Drop-in Assembly Interior.
• Sleeve & Cable Bushing.
• Easy-in pressure screw wiring
terminations.
Waterproof Cable Sealing:
• Neoprene Compression
Bushing Cable Locking System.
• Locking Bushing Nut with External
Cable Clamps.
• Bushing sizes available for any
cable size.
Durable & UL94-V0 Flame Rated
Housings
• DuraVhigh impact body and collars.
• Thermoset Interiors.
• Dead Front Construction.
Waterproof Locking Connections:
• Locking Screw Collars with
O-ring gaskets.
• Housing mechanical support and
pin and sleeve connection.
Dry Wiring Compartments:
• DurOringSealing System for each pin
& sleeve and interior assembly.
(50 Amp Plug & Connector Shown)
Lockout Capable:
(30/50A Plugs)
• Access Hole (not seen) For
Padlock Hasp.
• Interlock Engagement
CDA 360 Solid Brass Pin &
Sleeve Contacts.
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
The Ultimate in Waterproof Connection
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H47
H
Russellstoll ®
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 47
Performance – Electrical
Dielectric Voltage 3,000 Volts
Withstand
Max. Working 6000 volts RMS (minimum
creepage
Voltage and minimum clearance per UL
840)
Circuit Interrupting/ UL listed and CSA certified for
Load Breaking circuit interrupting at full rated
current.
Temperature Rise Max. 30°C temperature rise at full
rated current after 50 cycles of
overload at 150% rated current at
.75-pf.
Horsepower Per NEC 430-151 ratings
Performance – Mechanical
Impact Resistance Per UL 1682 Paragraph 34
Cord Round portable service cords. 10
Accommodation standard diameters from .405" to
1.00", custom sizes to spec.
Terminal In accordance with UL1682
Identification
Cable Pull Out In accordance with UL1682
Force
Product Identification label and molded in
Identification name
Lockout/Tagout Lockout/Tagout hole on plug
complies with OSHA Reg. 29 CFR
1910.147.
Performance – Environmental
Moisture Per UL1682 Paragraph 49.
Resistance Watertight/flap screw cover on
receptacle, O-Rings on all pins
and sleeves, interiors and plug
shell. Watertight even when not
engaged.
Flammability VØ or better per UL94
Operating Maximum Continuous: 95°C /
203°F
Temperatures Minimum: -40°C / -40°F w/o
impact
Chemicals Resists standard industrial
hydrocarbons, acids, bases and
solvents.
Material
Contact Carrier Molded arc resistant UL94-V0
Interior phenolic thermoset
Housing, Gland Nuts DuraV™ UL94-V0, High Impact
Screw Collar Rings Thermoplastic
O-Rings Buna-N (Nitrile)
Contacts: Pins Brass CDA 360
& Sleeves
Hinge Pins Stainless Steel
(Receptacle)
Terminals Brass CDA 360
Terminal Screws Stainless Steel
Flap Springs
Assembly Screws
Nuts, Hardware
Gland Friction 20 Amp - Nylon
Washer 30 & 50 Amp - Aluminum
Cable Clamp Bushing Neoprene
Approvals
E2630/E47956
LL14096
®
Engineering Specifications
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
H48 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 48
Catalog Numbers
Std. I.D.
Safety Bushing:
Voltage Polarization Plug/ Female
Amps Polarization (Receptacle) Male Plug Female Connector Conn.* Receptacle Female Plug Male Receptacle
❑❑ ♦
125 VAC 9P23U1__ 9C23U1__ 9R23U1W
250 VAC 9P23U2 9C23U2 9R23U2W
2P3W 277 VAC 9P23U3 9C23U3 9R23U3W
20A 480 VAC 9P23U4 9C23U4 9R23U4W
600 VAC 9P23U5 9C23U5 9R23U5W
thru 600VAC/250VDC 9P23U0 9C23U0 9R23U0W ❑♦
125 VAC 9P33U1 9C33U1 9R33U1W 9F33U1__ 9B33U1F
250 VAC 9P33U2 9C33U2 9R33U2W 9F33U2 9B33U2F
2P3W 277 VAC 9P33U3 9C33U3 9R33U3W 9F33U3 9B33U3F
30A 480 VAC 9P33U4 9C33U4 9R33U4W 9F33U4 9B33U4F
600 VAC 9P33U5 9C33U5 9R33U5W 9F33U5 9B33U5F
thru 600 VAC/250VDC 9P33U0 9C33U0 9R33U0W 9F33UØ 9B33UØF
125 VAC 9P53U1 9C53U1 9R53U1W 9F53U1 9B53U1F
250 VAC 9P53U2 9C53U2 9R53U2W 9F53U2 9B53U2F
2P3W 277 VAC 9P53U3 9C53U3 9R53U3W 9F53U3 9B53U3F
50A 480 VAC 9P53U4 9C53U4 9R53U4W 9F53U4 9B53U4F
600 VAC 9P53U5 9C53U5 9R53U5W 9F53U5 9B53U5F
thru 600 VAC/250VDC 9P53U0 9C53U0 9R53U0W 9F53UØ 9B53UØF
125/250 VAC 9P24U1 9C24U1 9R24U1W
250- 3ø VAC 9P24U2 9C24U2 9R24U2W
3P4W 480 3ø VAC 9P24U4 9C24U4 9R24U4W
20A 600 3ø VAC 9P24U5 9C24U5 9R24U5W
thru 600VAC / 250VDC 9P24U0 9C24U0 9R24U0W
125/250 VAC 9P34U1 9C34U1 9R34U1W 9F34U1 9B34U1F
250 3ø VAC 9P34U2 9C34U2 9R34U2W 9F34U2 9B34U2F
3P4W 480 3ø VAC 9P34U4 9C34U4 9R34U4W 9F34U4 9B34U4F
30A 600 3ø VAC 9P34U5 9C34U5 9R34U5W 9F34U5 9B34U5F
thru 600 VAC/250VDC 9P34U0 9C34U0 9R34U0W 9F34UØ 9B34UØF
125/250 VAC 9P54U1 9C54U1 9R54U1W 9F54U1 9B54U1F
250 3ø VAC 9P54U2 9C54U2 9R54U2W 9F54U2 9B54U2F
3P4W 480 3ø VAC 9P54U4 9C54U4 9R54U4W 9F54U4 9B54U4F
50A 600 3ø VAC 9P54U5 9C54U5 9R54U5W 9F54U5 9B54U5F
thru 600 VAC/250VDC 9P54U0 9C54U0 9R54U0W 9F54UØ 9B54UØF
Standard
0.625
For Optional
Sizes
See pg. H51
Add Suffix - / xxxx for bushing I.D. (page 51) or conduit adapter assembled.
“W” suffix is watertight “F” suffix for splashproof spring flap cover.
* Consult Technical Services.
DuraGard®Waterproof Connections – Ordering Information
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
Standard
0.700
For Optional
Sizes
See pg. H51
Standard
0.925
For Optional
Sizes
See pg. H51
Standard
0.625
For Optional
Sizes
See pg. H51
Standard
0.750
For Optional
Sizes
See pg. H51
Standard
0.925
For Optional
Sizes
See pg. H51
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H49
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 49
Amps A* B C* Max AWG Terminal
Ø in./mm
20 Amp Inches 3.87 2.16 2.75 12 .140/.0055
mm 98.3 54.9 69.9
30 Amp Inches 5.385 2.38 4.16 8 .235/.0092
mm 136.6 60.5 105.7
50 Amp Inches 5.75 2.38 4.16 6 .235/.0092
mm 146.1 60.5 105.7
A
B
C
D
E
Plugs and Female Plugs (30/50A only) Connectors
* Note – Dimensions will vary slightly with assembly.
Receptacles and Male Receptacles (inlets – 30/50A only)
Amps F G H I J K M Max. AWG Terminal
Ø in/mm
20 Amp Inches 4.14 3.25 2.66 1.88 1.49 2.26 3.17 12 .140/.0055
mm 105.2 82.6 67.6 47.8 37.8 57.4 80.5
30 Amp Inches 4.14 3.25 2.66 1.88 2.44 2.71 4.12 8 .235/.0092
mm 105.2 82.6 67.6 47.8 62.0 68.8 104.6
50 Amp Inches 4.14 3.25 2.66 1.88 2.44 2.71 4.12 6 .235/.0092
mm 105.2 82.6 67.6 47.8 62.0 68.8 104.6
Screw cover shown. Flap cover also available; no dimensional changes.
Dimensions
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
Amps D E Max AWG Terminal
Ø in./mm
20 Amp Inches 4.75 1.88 12 .140/.0055
mm 120.7 47.8
30 Amp Inches 6.25 2.13 8 .235/.0092
mm 158.8 54.1
50 Amp Inches 6.25 2.13 6 .235/.0092
mm 158.8 54.1
H50 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 50
Max. Cable O.D. (Inches) 20 Amp 30 & 50 Amp
0.375 C16984A
0.437 C16984B
0.500 C16984C
0.545 2000-11
0.562 C16984D
0.606 B16506
0.620 2000-03
0.625 B16524
0.700 2000-04
0.750 2000-01
0.800 2000-06
0.870 2000-02
0.925 2000-12
1.000 2000-05
Cast Aluminum Cast Brass Use with:
Single 3711A 3731 20A,
Double 3712A 3732 30A
DSFD 3781A 3782 50A
Size 20 Amp 30 Amp 50 Amp
d"9X2C50 ––
f" 9X2C75 9X3C75 9X5C75
1" 9X3C10 9X5C10
Cast Aluminum Cast Brass
3678A 3678B
Conduit Boxes (For Surface Mounting)
45° Angle Adapter
Note: f" NPT Hole Std.
Additional Accessories Are Available. Consult Factory.
Conduit Adapter Kits
(Plugs or Connectors)
Screw Cap / Cup Cap
20 Amp 30 Amp 50 Amp
Screw Cap (Connector) 9X2PSC 9X3PSC 9X5PSC
Cup Cap (Plug) F26874C F26874C
Material – oil resistant neoprene.
State Catalog number followed by slash/ __ and bushing code;
Example: 9P33U1/1000
20 Amp
Cable Bushing
30 & 50 Amp
Cable Bushing
Type FD
4.12"
.31"
4.12"
2"
2.62"
3.62"
3.18"
MTG
.31"
2 MTG. Holes
4.37"
MTG
Catalog Number 3781A
DuraGard®Waterproof Connections – Accessories
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
Note: _ Suffix to plugs/connectors for
assembly from factory.
(Minimum Limit 85% of O.D. Size for Sealing)
Cable Bushings
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H51
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 51
Catalog Numbers
Amps Voltage Polarization Male Interior Assembly Female Interior Assembly
125VAC 9XM23U1 9XF23U1
250VAC 9XM23U2 9XF23U2
2P3W 277VAC 9XM23U3 9XF23U3
20A 480VAC 9XM23U4 9XF23U4
600VAC 9XM23U5 9XF23U5
thru 600VAC / 250VDC 9XM23U0 9XF23U0
125VAC 9XM33U1 9XF33U1
250VAC 9XM33U2 9XF33U2
2P3W 277VAC 9XM33U3 9XF33U3
30A 480VAC 9XM33U4 9XF33U4
600VAC 9XM33U5 9XF33U5
thru 600VAC / 250VDC 9XM33U0 9XF33U0
125VAC 9XM53U1 9XF53U1
2P3W 250VAC 9XM53U2 9XF53U2
50A 480VAC 9XM53U4 9XF53U4
600VAC 9XM53U5 9XF53U5
thru 600VAC / 250VDC 9XM53U0 9XF53U0
125VAC 9XM24U1 9XF24U1
3P4W 250VAC 9XM24U2 9XF24U2
20A 480VAC 9XM24U4 9XF24U4
600VAC 9XM24U5 9XF24U5
thru 600VAC / 250VDC 9XM24U0 9XF24U0
125VAC 9XM34U1 9XF34U1
3P4W 250VAC 9XM34U2 9XF34U2
30A 480VAC 9XM34U4 9XF34U4
600VAC 9XM34U5 9XF34U5
thru 600VAC / 250VDC 9XM34U0 9XF34U0
125VAC 9XM54U1 9XF54U1
3P4W 250VAC 9XM54U2 9XF54U2
50A 480VAC 9XM54U4 9XF54U4
600VAC 9XM54U5 9XF54U5
thru 600VAC / 250VDC 9XM54U0 9XF54U0
Replacement Interiors
DuraGard®Waterproof Connections – Accessories
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
H52 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 52
3P4W
50A
Features & Benefits
Circuit Breaker Interlocked Outlet.
• 30A & 50A ranges and polarizations to 480VAC.
• 22KA Interrupt Capacity Breaker.
• Easy handle reset after trip.
• Auxiliary switch or other options.
User Friendly – Flexible Mounting.
• Variable footprint mounting tabs.
• Compact size fits 8" standard I-Beam webs.
• Conduit entry from top, bottom or side.
• Large red handle with lockout access.
Flame Rated & DuraVTough Housing.
• UL94-V0 housing and interior with
Stainless Steel components.
• High impact thermoplastic housing.
• NEMA 4X construction.
Dimensions
7.00
5.25
MTG
13.47
MTG
13.46 12.00
8.13
“A”
side
entry
“B” conduit
entry standard
The only non-metallic, 22KAIC, 20, 30, & 50A series circuit breaker
interlocked receptacle available today.
3P4W
30A
Notes: 1. Change suffix for alternate trip ratings. Example: 9MT54U2W30B - 50 Amp, 3P4W, Safety Interlock with 30 Amp circuit breaker, conduit top entry.
Change
“W” to “F” for flap cap access. Example: 9MI34U2F30B - 30 Amp, 3P4W, Safety Interlock with
non-automatic safety switch and flap cap.
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
Safety Interlocks
Ordering Information
Cat. No.
3P4W examples shown: Safety Interlock
Safety Interlock Circuit Breaker Mating With Non-Automatic
AMPS Voltage Polarization With Circuit Breaker Trip Rating Plug Safety Switch
1
125/250 VAC 9MT34U1W30B 30A 9P34U1 9MI34U1WNAB
250 3Ø VAC 9MT34U2W30B 30A 9P34U2 9MI34U2WNAB
480 3Ø VAC 9MT34U4W30B 30A 9P34U4 9MI34U4W
NA
B
600 3Ø VAC 9MT34U5W30B 30A 9P34U5 9MI34U5WNAB
Thru 600 VAC/ 3P4W 9MT34U0W30B 30A 9P34U0 9MI34U0
WNA
B
125/250 VAC 9MT54U1W50B 50A 9P54U1 9MI54U1WNAB
250 3Ø VAC 9MT54U2W50B 50A 9P54U2 9MI54U2W
NA
B
480 3Ø VAC 9MT54U4W50B 50A 9P54U4 9MI54U4WNAB
600 3Ø VAC 9MT54U5W50B 50A 9P54U5 9MI54U5W
NA
B
Thru 600 VAC/ 3P4W
9MT54U0W50B 50A 9P54U0 9MI54U0WNAB
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H53
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 53
®
Safety Interlocks Engineering Specifications
Performance – Electrical
Dielectric Voltage 3,000 Volts
Withstand
Max. Working 480 volts RMS (minimum creepage
Voltage distance and minimum clearance
per UL 840) (using circuit breaker)
Circuit Interrupting/ UL listed and CSA certified for
Load Breaking circuit interrupting at full rated
current.
Temperature Rise Max. 30°C temperature rise at full
rated current after 50 cycles of
overload at 150% rated current at
.75-pf.
Shrouded Contacts Complies with California Code Title
8, Art. 51,S2510.7(b) for devices
exceeding 300 VAC
Horsepower Exceeds NEC 430-151 ratings
(Circuit Breaker)
Performance – Mechanical
Impact Resistance Per UL 1682 Paragraph 34
Wiring Conduit Entries at top, side and
Accommodation bottom. .750" NPT top entry
standard
Terminal In accordance with UL1682
Identification
Plug Pull Out In accordance with UL1682
Force
Product Identification label
Identification
Lockout/Tagout Lockout/Tagout access on switch
complies with OSHA Reg. 29 CFR
1910.147
Performance – Environmental
Moisture Per UL1682 Paragraph 49.
Resistance Watertight/flap screw cover on
receptacle, O-Rings on all pins
and sleeves, interiors and plug
shell. Watertight even when not
engaged. (Screw cover closed /
locked)
Flammability VØ or better per UL94
Operating Maximum Continuous: 95°C /
203°F
Temperatures Minimum: -40°C / -40°F w/o impact
(note: per C/B trip curves at
elevated temps.)
Chemicals Resists standard industrial
hydrocarbons, acids, bases and
solvents.
UV Resistance UV stabilized material.
Material
Contact Carrier Molded arc resistant UL94-V0
Interior thermoset material
Housing, Gland Nuts DuraV™ UL94-V0, High Impact
Screw Collar Rings Thermoplastic
O-Rings Buna-N (Nitrile)
Contacts: Pins Brass CDA 360
& Sleeves
Hinge Pins Stainless Steel
(Receptacle)
Terminals Brass CDA 360
Terminal Screws Stainless Steel
Flap Springs
Assembly Screws
Nuts, Hardware
Approvals
DuraGard®Waterproof Connections
Washdown Duty, Chemical, Outdoor, Industrial & Marine Use Non-Metallic Plugs, Connectors Receptacles & Inlets – 20, 30 &
50 Amp, Maximum 600 VAC/250 VDC
H54 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H03 DGARD 3/5 3/14/03 6:45 PM Page 54
The FS/FD general purpose interconnection system is
designed for lower amperage marine and rough service
applications, with rugged die cast aluminum housings and
epoxy powder coated finishes. Interlocked receptacles add
Branch Circuit protected outlet capability, and base
receptacles fit existing Russellstoll FS, FD and DSFD single
and multi-gang back boxes. Its versatility and watertight
features make it ideal for marine and light industrial
applications.
Safety
Circuit-interrupting up to 30A, 250VAC
(20A, 600VAC)
Factory polarized interiors provide for mating of same
voltage/same type devices, thru configured ground pins and
housing features.
Shell grounding by means of ground strap integral with ground
contact for assured assembly safety.
Durability
Constructed of copper-free cast aluminum (Brass construction
also available).
Optional conduit adapters, strain reliefs and cable bushings
available. (Modified catalog number construction.)
Non-metallic versions of most metallic plugs and receptacles
also available. (See DuraGard)
Performance
Precision-made, self-aligning and self-wiping contacts.
Devices available in watertight and weathertight versions.
Solderless binding screw terminals for convenient wiring.
(20A, 2P3W devices have set screw pressure terminals)
FS/FD line also includes NEMA type blade receptacles. See page H62.
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H55
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 55
Plug & Connector ( + Reverse Service Female Plug)
Receptacle ( + Reverse Service Male Inlet)
Gasketed screw collar for watertight connection when plug is mated to
receptacle or connector.
Cast aluminum, corrosion resistant copper-free alloy or cast
brass housings, for rough duty or marine service.
2 Layer electrostatic epoxy powder coat finish.
Gland nut and oil resistant neoprene cable bushing
gland to prevent dust and moisture accumulation.
Compression-style cable bushing and
gland nut system. External cable clamping
or conduit fitting adapters available
separately or as standard product.
(Modified catalog number can include
special construction or bushing size.)
6 Voltage polarizations
available from U0-U5.
(2p3w; 3p4w in UØ)
Ground contacts
“make first” and
“break last” for safety.
Furnished with single gang conduit box standard; die cast or heavy duty thick wall cast boxes
available (copper-free aluminum or brass). Can be pre-drilled to customer specification.
Water proof gasketed flap-screw cap.
Molded arc-resisting interiors with precision made, self-
wiping, self-aligning brass contacts.
Housings positively grounded by phosphor bronze
ground straps integral with ground contact.
Contacts “make” first and “break” last for safe ground.
Available in brass for marine applications.
FDWS-62 box shown.
See accessories for complete
box selections.
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
H56 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 56
Performance – Electrical
Dielectric Voltage 3,000 Volts
Withstand
Max. Working 600 volts RMS (minimum creepage
Voltage distance and minimum clearance
per UL 840)
Circuit Interrupting/ UL listed and CSA certified for
Load Breaking circuit interrupting at full rated
current.
Temperature Rise Max. 30°C temperature rise at full
rated current after 50 cycles of
overload at 150% rated current at
.75-pf.
Shrouded Contacts Complies with California Code Title
8, Art. 51,S2510.7(b) for devices
exceeding 300 VAC
Horsepower Per NEC 430-151 ratings (non-
interrupting)
Performance – Mechanical
Impact Resistance Per UL 1682 Paragraph 34
Cord Round portable service cords per
Accommodation UL standard 62 & CSA C22.2 No.
49.1
Terminal In accordance with UL1682
Identification
Cable Pull Out In accordance with UL1682
Force
Product Identification label and name
Identification per UL 1686
Performance – Environmental
Moisture Per UL1682 Paragraph 49.
Resistance Watertight/flap screw cover on
receptacle.
Flammability VØ / 5VA per UL94
Operating Maximum Continuous: 95°C /
203°F
Temperatures Minimum: -40°C / -40°F w/o
impact
Chemicals Resists standard industrial
hydrocarbons, acids, bases and
solvents.
Material
Contact Carrier Thermoset
Interior
Housing, Gland Nuts Cast Aluminum or Brass
Screw Collar Rings
Contacts: Pins Brass
& Sleeves
Hinge Pins Stainless Steel
(Receptacle)
Terminals Brass
Terminal Screws Stainless Steel
Flap Springs
Assembly Screws
Nuts, Hardware
Gland Friction Washer Brass or Aluminum
Cable Clamp Bushing Neoprene
Approvals
E2630/E47956 LR14096
®
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Engineering Specifications
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H57
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 57
Poles Polarization Aluminum Cast Brass Aluminum Cast Brass
Wires Amperes Voltage (Receptacle)
250 V 3720U-2 3720BU-2 3913U-2 3913BU-2
277 VAC 3720U-3 3720BU-3 3913U-3 3913BU-3
15 A 480 VAC 3720U-4 3720BU-4 3913U-4 3913BU-4
600 VAC 3720U-5 3720BU-5 3913U-5 3913BU-5
250 VAC 3720 3720B 3913 3913B
20 A 125 V 3720U-1 3720BU-1 3913U-1 3913BU-1
30 A 250 VAC 3750 3750B 3933 3933B
10 A 600 VAC 3730 3730B 3914 3914B
15 A 250 VAC 3730 3730B 3914 3914B
20 A 600 VAC 3760 3760B 3934 3934B
30 A 250 VAC 3760 3760B 3934 3934B
2P3W3P4W
Cable Bushings – oil-resistant, neoprene cable bushing is regularly
furnished with hole sizes listed above. Other hole sizes are available at
no extra cost when specified on order. See page H61 for available sizes.
Screw Caps For Connectors can be furnished with retained screw
cap at extra cost. For Kits order:
9X2PSC 20A Screw Cap
9X3PSC 30A Screw Cap
F26874C 30A Plug Cup Cap
Standard Cable Bushing Hole Diameter
Prefix Hole Dia. Prefix Hole Dia. Prefix Hole Dia.
3720 3730 3750, 3760
3913 e" 3914 W" 3933, 3934 f"
3789 3790 3809, 3810
For other plug & connector accessories see pages H62 and H63 H61
Plugs can be furnished with adapters to accommodate rigid conduit or
standard connectors for armored cable or flexible conduit, see page H61.
*See also DuraGard section for Thermoplastic families.
FS/FD10-30A Metallic – Ordering Information
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Male Plugs Female Connectors
H58 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 58
(Inlets)
Aluminum Cast Brass Aluminum Cast Brass Aluminum Cast Brass
with Box ** with Box ** w/Box FDWS-62 w/Box 3731
3743U-2 3763U-2 3789U-2 3789BU-2 3776U-2 3779U-2
3743U-3 3763U-3 3789U-3 3789BU-3 3776U-3 3779U-3
3743U-4 3763U-4 3789U-4 3789BU-4 3776U-4 3779U-4
3743U-5 3763U-5 3789U-5 3789BU-5 3776U-5 3779U-5
3743 3763 3789 3789B 3776 3779
3743U-1 3763U-1 3789U-1 3789BU-1 3776U-1 3779U-1
3753 3773 380913809B13796237993
3744 3764 3790 3790B 3777 3780
3744 3764 3790 3790B 3777 3780
3754 3774 3810 3810B 3797 3800
3754 3774 3810 3810B 3797 3800
1 Also in plastic. Use 3809P or 9F33UO
2 Also in plastic. Use 3796P – Aluminum back box (use 3797-P for brass)
3 Also in plastic. Use 3799P (Brass J-Box) or 9B33UØF (w/o J-Box)
Material Amperes Box
Aluminum 10, 15 & 20 FSWS-62
30 FDWS-62
Brass 10, 15 & 20 3721
30 3731
Notes:
• For 20/30A thermoplastic devices, see DuraGard section.
• Mating with DuraGard Line
-20A devices will mate and lock across lines.
-30A metal male devices cannot mate to DuraGard 30A female devices can be mixed.
** Receptacles come with the following boxes:
Female Plugs Male Receptacles
For NEMA style (bladed) Convenience
Receptacles, see page H62.
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Female Receptacles Reverse Service
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H59
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 59
Amps A B C E F G H
10 Amp Inches 1.75 3.62 2.25 2.00 4.00 1.87 0.75
mm 45.65 92.07 57.15 50.80 101.60 47.62 19.050
15 Amp Inches 1.75 3.62 2.25 2.00 4.00 1.87 0.75
mm 45.65 92.07 57.15 50.80 101.60 47.62 19.050
20 Amp Inches 1.75 3.62 2.25 2.00 4.00 1.87 0.75
mm 45.65 92.07 57.15 50.80 101.60 47.62 19.050
30 Amp Inches 1.87 3.75 2.25 2.25 4.25 2.25 1.12
mm 47.62 95.25 57.15 57.15 107.95 57.15 28.57
B
CHE
Max. Cable
Dia.
A
G
FH
G
Max. Cable
Dia.
Plugs and Female Plugs Connectors
Receptacles & Male Receptacles
Plug, Female Plug & Connector Dimensions
Standard Die Cast Aluminum Back Box
(FSWS/FDWS)
Cast Aluminum / Cast Brass Back Box
(3701-3732 Series)
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Dimensions
H60 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 60
Hole Diameter Type 2 Type 3
for Cable (inches) 10 Amp 20 & 30 Amp
.313 SG05
.375 SG1 JG31
.438 SG15
.500 SG2 JG32
.531 SG2A
.563 SG25 JG325
.594 SG2B
.625 SG3 JG33
.688 SG3A
.750 SG4 JG34
.875 JG35
1.000 JG36**
1.125 JG361**
Adapter tapped with NPT thread to accommodate
armored and non-metallic cable or flexible conduit.
Plug or Cast Cast
Connector Aluminum Brass Tapped
Size Cat. No. Cat. No. NPT
Ex: 3913 FSA11 FSA11B d"
10 -20 Amp FSA12 FSA12B f"
Ex: 3934 FSA21 FSA21B d"
20/30 Amp FSA22 FSA22B f"
FSA23 FSA23B 1"
Type FSA furnished complete with gasket.
Combination Gland Nut and Cable Clamp Conduit Adapters
Cable Bushings
Material – oil resistant neoprene.
**Special for large O.D. cable.
Type 2
Cable Bushing
Type 3
Cable Bushing
For Plugs & Connectors – Accessories
Provides extra clamping protection in hard service
applications. Relieves terminals and rubber gland of all
cable strain.
Plug or Cast Cast Max.
Connector Aluminum Brass Cable
Size Cat. No. Cat. No. Dia.
Ex: 3913 3905 3905B .62"
10-20 Amp
Ex: 3934 3906 3906B 1.12"
20/30 Amp
Notes:
Material – cast aluminum, corrosion-resistant, copper-free alloy, cast brass,
epoxy powder coat finish.
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Notes:
When standard plugs or connectors are required to be furnished with one or more of
the above accessories, add the suffix and catalog number of the accessory selected to
the catalog number of the plug or connector. Complete list price is the total of the list
price of the device plus the list price of the accessory.
EXAMPLES – Using Catalog No. 3934:
Combo. Gland Nut & Cable Clamp 3934-3906
Adapter at f" 3934-FSA22
d" Cable Bushing 3934-JG323
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H61
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 61
Weathertight (Flap Cap) Watertight (Screw Cap)
Cast Aluminum
2P3W NEMA Aluminum Brass (FDWS-62)uAluminum Brass
Rating* Duplex Receptacle Single Receptacle Duplex Receptacle Single Receptacle Single Receptacle
15 Amp 125V 3998G** 3918G 3960G 3910G 3920G
5-15
20 Amp 125V 3998G-20** 3918G-20 3960G-20 3910G-20 3920G-20
5-20
Convenience Bladed NEMA Style Receptacles
Dimensions
Duplex Receptacles
2.75"
MTG
4.81"
2.66"
4.87" MTG
.28" Dia.
(2) MTG
Holes
3"
.75" Max. Conduit
A
B
D
C
Notes:
Finish – Cast aluminum, corrosion-resistant copper-free alloy, epoxy powder coat
finish. Cast brass, national finish.
Gang Types – Can be furnished in gang or tandem units in combination with other
Russellstoll FS/FD devices. See Accessory reference charts on page H24 for more
information.
Outlets – Unless otherwise specified, furnished with one
f" outlet at B or D. Additional or larger outlets charged extra –
see price list. Maximum outlet one inch, four way. Specify size
and location. Use symbols as indicated on diagram.
* Can be furnished with 250 Volt receptacles. Price on application. All the above
receptacles accommodate standard convenience-type plugs.
** The aluminum duplex cover assembly will accept many varied electrical and
electronic devices. Please contact your local representative or the factory with your
requirements.
Furnished with stamped Flap Cover made of heavy gage steel, cadmium plated, with
spring-hinged flap.
FS/FD10-30A Metallic
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Designed for rugged service/commercial interface, the
receptacles below accommodate standard bladed
convenience type plugs. They can be furnished in single or
tandem units and in combination with other Russellstoll
FS/FD devices. Each includes a standard heavy duty cast
back box.
Ordering Information
H62 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 62
Conduit Boxes
Type FS (shallow) & Type FD (deep)
No. of Gangs Type Cast Aluminum Cast Brass *Overall Dimensions For Use With:
FS 3701A 3721 4.12" x 2.62" x 2.31" 15-20A
Single FD 3711A 3731 4.12" x 2.62" x 2.94" 30A
DSFD 3781A 3782 4.12" x 3.62" x 4.12" 30A
Two FS 3702A 3722 4.12" x 5.5" x 2.25" 15-20A
FD 3712A 3732 4.12" x 5.62" x 2.87" 30A
Single Gang Two Gang DSFD
Notes:
When type FD devices (20A) are to be mounted in boxes, type FD boxes should be
used. FS boxes will not accommodate FD devices. (30A or 3P4W)
Mounting – all the above boxes are for surface mounting. For flush mounting see
page H64.
Boxes – Cast brass, natural finish. Cast aluminum, corrosion resistant
copper-free alloy, epoxy powder coat finish.
* Dimensions are overall exclusive of conduit pads and mounting lugs.
Outlets – unless otherwise specified, furnished with one .75" outlet per gang, top or
bottom. Additional outlets charged extra – see price list. Specify size and location.
Maximum Conduit – FS and FD: 1", one per gang top and bottom and one each side.
DSFD: one 1.5" or two .5" top and bottom.
Cast iron available on special order – consult factory.
Dimensions
FS/FD DSFD Multiple Gang
A
1.38
.31
4.50
1.06
4.12
3.00
MTG
2.62 Ø.28, 4 PLS
3.38 MTG
FS/FD10-30A Metallic – Accessories
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
Aluminum boxes have 6-32 cover mounting holes tapped to
accommodate all FS and FD cover assemblies. Brass boxes
have 10-24 cover mounting holes tapped to accommodate all
FS and FD cover assemblies.
4.12"
.31"
4.12"
2"
2.62"
3.62"
3.18"
MTG
.31"
2 MTG. Holes
4.37"
MTG
B"
A" –
MTG.
4 MTG.
Holes
3"
MTG.
2.87"
AB
FS FD FS FD
6.50" 6.50" 5.50" 5.62"
Type A
FS 2.31
FD 2.94
Multiple Gang Dimensions
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H63
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 63
Adapter Flush Frames*
For mounting to standard wall outlet boxes (2 screw mount).
Adapters and covers to fit boxes on page H64-H65.
Blank Cover* Flush Wall Mounting Extension*
Covers Standard FS/FD box openings.
Cast Aluminum 3677A
Cast Brass 3687
Cast Aluminum 3679A
Cast Brass 3679B
No. of Gangs Cast Aluminum Cast Brass Overall Dimensions
13671A 3681 5" x 3.5"
23672A 3682 5" x 6.5"
2.95"
1.87"
3.25" 4.15"
.15"
1.87"
5" 3.25"
2.62"
3.5"
4.12"
2"
3.25"
1.87"
1.87"
.21" DIA.
4 MTG.
Holes
Front Back
FS/FD10-30A Metallic – Accessories
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
H64 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 64
45° Angle Adapter*
Mounts to any FS/FD box.
Cast Aluminum 3678A
Cast Brass 3678B
Notes:
* Furnished complete with gasket and screws.
Materials: Cast aluminum, corrosion-resistant, copper-free alloy, epoxy powder coat
finish. Cast brass, natural finish.
2.25"
MTG.
4.87"
MTG.
2.25"
4.81"
.28" Dia.
(2) MTG.
Holes
4.87"
MTG.
2.25"
MTG.
.28" Dia.
(2) MTG.
Holes
2.25"
5.37"
.75"
.25"
2.94"
2.31"
Conduit Entries
Cat. No. Top Bottom
FSWS-62 f" NA
FDWS-62 f" NA
FDWS-622 f" f"
FDWS-63 1" NA
FDWS-633 1" 1"
Type FSWS and FDWS (with mounting shelf
for box-mounted devices)
Aluminum Die-Cast Boxes with cover mounting holes tapped
for 6-32 screws to accommodate all FS and FD cover
assemblies.
Notes: Boxes – Aluminum die-cast, corrosion-resistant, copper-free alloy, epoxy powder
coat finish.
Outlets – standard as listed.
Mounting – all of the above boxes are for surface mounting.
FS/FD10-30A Metallic – Accessories
Metallic Plugs, Connectors, Receptacles and Reverse Service Female Plugs/Male Inlets.
10-30A, Maximum 600 VAC/250VDC
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H65
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 65
Marine/Series Industrial – 20 & 30 Amp, 250VAC
Mechanically interlocked FS/FD Interface receptacle outlets,
available through 30 Amp 250VAC, provide added electrical
safety during in branch circuits.
By design, the plug must be fully inserted into the
interlocked receptacle before the switch or circuit breaker
can be turned to the “ON” position; and the switch or circuit
breaker must be in the “OFF” position before the plug can
be withdrawn. This design ensures that when properly
installed and operated, the circuit is made and broken by
the switch or circuit breaker, not by the connectors.
As with all Russellstoll products, Mechanically Interlocked
receptacles were designed with Safety, Durability and
Performance in mind.
Safety
Mechanical linkage prevents plug insertion or withdrawal
unless switch is in “off” position.
Circuit breaker protection available on many models.
Ground contacts make first, break last.
Durability
Constructed of copper-free cast aluminum (some types
available in brass)
Sturdy die cast and sand cast housings.
Performance
Precision-made, self-aligning and self-wiping contacts.
Receptacles provided with spring-actuated, self-closing
flaps.
Devices available in watertight and weathertight versions.
Solderless screw terminals for convenient wiring.
Mechanically Interlocked Receptacles
H66 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 66
Mechanically Interlocked Receptacle with Circuit Breaker
Mechanically Interlocked Receptacle with Switch
Poles/ Trip Aluminum FS/FD DuraGard Bushing
Wires Rating Receptacle w/Box Plug Plug I.D.
2P3W 20A F33048B 3750 9P33UØ e"
30A F33048C 3760
3P4W 20A F33054B 3760 9P34UØ f"
30A F33054C 3760
50A, 250V*
3P4W 50A C1479AH 3760 9P34UØ* g"
Aluminum** FS/FD Brass FS/FD DuraGard Bushing
Poles/Wires Receptacle w/Box Plug Receptacle w/Box Plug Plug I.D.
2P3W F20493C 3750 1593LP 3750B 9P33UØ e"
3P4W F20493A** 3760 1594LP 3760B 9P34UØ f"
Rating:
20 Amp/600VAC
30 Amp/250VAC
**Flap cover brass version Suffix -B.
Rating:
20 Amp/250VAC
30 Amp/250VAC
Note: For Panel Mounting or Cover Assemblies only, please contact factory.
* Consult Technical Services for all 50A Trip applications (30a device, 50A trip) See also DuraGard Interlocks.
For brass versions, contact Technical Services.
Mechanically Interlocked Receptacles – Ordering Information
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H67
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 67
Interlocked with Switch Surface Mount
Dimensions
Interlocked with Circuit Breaker
4.5"
6.75"
4.81"
2.93" 1.87"
1.25" Max. Conduit
Top & Bottom only
5.06"
5.87"
MTG
5.43"
.34" Dia.
4 MTG.
Holes
7.50"
6.75"
8.50"
.34"
5.25"
Plugged Drainhole
(1/8" 27 NPT)
Machine Panel Mount Floor Extension Mount
4.5"
6.75"
2.5"
3.37"
6.37"
5.46"
3.12"
3.68"
.37" .87"
.75"
12-24 NC
28 Tap
6 Req'd
.43"
45°
3.37"
Standard Plug
4.88"
2.13"
A
B
C
Amps A* B C*
30 Amp Inches 5.38 2.38 4.16
mm 136.6 60.5 105.7
50 Amp Inches 5.75 2.38 4.16
mm 146.1 60.5 105.7
30/50 Amp DuraGard
20/30 Amp FS/FD
(also as replacement cover assembly)
Cat. nos. F18196B&C and F20493A&B
Housings:
Cast Brass, Natural Finish.
Cast Aluminum, corrosion-resistant, copper-free alloy, epoxy
powder coat finish.
Cable Bushings: Oil resistant neoprene strain-relief cable
bushings regularly furnished with hole size as listed for plug.
Other hole sizes available if specified on order. See
Accessory Reference Section, Bushing Sizes Page H61.
Outlets: Unless otherwise specified, boxes are furnished
blank.
Receptacle Interlocked With Switch –
Maximum conduit outlets 1f" top
and bottom. Specify outlets required.
Receptacle Interlocked With Circuit
Breaker – Maximum conduit outlet
1f" at locations V, W, X, Y and Z
as per diagram. Specify outlets
required, use symbols.
A
B
D
C
Specifications
Switch
Circuit Breaker
Mechanically Interlocked Receptacles
H68 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H04 FS/FD 3/5 3/14/03 6:47 PM Page 68
Safety, Performance and Durability… In A Snap!
Extensive Product Family
• Safe and reliable, portable electrical connections.
• Wide variety of Plugs, Connectors, Receptacles, Inlets and Mounting Boxes.
• Watertight (IP67) and Splashproof (IP44) versions available.
• 20, 30, 60 and 100 Amp ratings for small, medium or large current loads.
• CULus Listed for North American ratings.
• UL classified to IEC309-1 and IEC309-2 for North American and
International ratings.
• Complete interchangeability with all manufacturers’ IEC309-1 and
IEC309-2 devices.
• Meets IEC309 global configurations for safety in industrial applications.
Watertight
• Watertight design and construction meet stringent IP67 internal
protection standards.
• Rugged thermoplastic housings resist impact or abuse and provide
excellent corrosion resistance.
• Unique Thomas & Betts strain relief grip and sealing system assure
superior cable retention and watertight conductor termination.
• Ideal for outdoor, wet, marine and washdown applications.
• Unique 75% faster assembly with EZ Clik™ handle locking, and EZ Tite™
cable grip system.
Splashproof
• Suitable for indoor use where splashing liquids and other contaminants
may interfere with electrical connections.
• Ideal for most heavy commercial applications and light industrial
applications.
• Available in 20 and 30 Amp ratings.
UniGardPin & Sleeve IEC Connector
Beverage
Plants
Construction
Sites
Food
Processing
Marine and
Shipboard
Pulp &
Paper Mills
Chemical
Plants
E2630
E47956
E205590
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H69
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:49 PM Page 69
EZ Cliklocking mechanism
UniGardSafety, Performance and Durability
Safe Connections Standard –
Ground contacts make first, break last for safe
connections even under load.
The Easy Way –
EZ Cliklocking
feature on all 20/30A plugs
and connectors.
Self-Aligning Solid Contacts –
• Self-aligning Nickel plated full-round pins
and sleeves for maximum cool contact area.
• Sleeve pressure rings ensure constant
surface contact force.
• Nickel plating offers maximum corrosion for
any use.
75% Faster Cable Builds – EZ TITESystem
• One-piece cable gland.
• Nylon locking screw prevents loosening.
• EZ hand assembly of cable gland, Grip Tite™ 6-Finger
clamp and onion-ring bushing.
Screw Collars Stay Put –
Turreted grip allows for easy
handling.
H70 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:49 PM Page 70
Standard Interface / World Ready
Full International Compliances –
EN60309
UL Classification to IEC309-1 and IEC309-2.
CULus Listing: UL1682/1686 and CSA C22.2
No. 182.1.
CE conforms to EC Low Voltage Directive.
North American and Global Voltage
Polarization “clock positions” available in all
standard ratings.
Solid, Safe Voltage Selections –
One-Piece contact carriers with Full-Color IEC
standard voltage-phasing Coding ensures
correct product application every time.
Combination Flap/Screw Cover –
• Integral neoprene gasket for IP67 Watertight protection.
• Standard flap cover for IP44 Splashproof protection.
• Unique flex hinge design.
Solid Neoprene
Gasket In Handle
Neoprene Cable Bushing –
• Onion ring design.
• Universal fit capability.
Fast and Easy Wiring –
• Unique, one-way terminal
access.
• Clearly marked terminal
connections.
Double Secure Wiring –
• Dual, combination point
terminal screws for failsafe
connections.
Grip Tite6-Finger Clamp –
Provides superior cable retention.
Raised Ground Terminal –
Ensures safe connections every time.
Secure Grip Handle –
• Tapered shoulder (20/30A).
• Ribbed (60/100A).
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H71
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 71
The UniGardDifference
Features
No Tools, No Screws Necessary
• EZ Clik™ locking handle saves 75% on assembly time.
• Unique EZ Clik™ assembly feature on 20 and 30 Amp plugs and connectors
makes installation and inspection fast and reliable.
• Captured gaskets in handles seal out water, chemicals and dust.
Simple Cable Clamping
• Threaded EZ Tite™ cable gland on 20 and 30 Amp devices makes assembly
fast and easy.
• One-piece lock screw verifies clamp locking hold, with no external metal contact
possible. (20 and 30 Amp devices)
The Performance Connection
• Watertight spring-loaded covers with high-strength flex-hinge screw covers on
IP67 devices.
• Flap covers on IP44 splashproof styles.
• Safety, performance and durability for all IEC309 applications worldwide.
Unique Fast Assembly
• One-piece EZ Tite™ cable gland with locking screw loads to cable followed by
Grip Tite™ 6-Finger cable clamp/grip piece.
• Watertight onion ring bushing fits a wide variety of outside diameters.
Easy Action Single-Wiring Point Access Saves
Time Wiring
• All terminal screws face in same direction allowing installer to make safe and
secure conductor terminations in 30% less time than other devices.
• Rugged, corrosion free thermoplastic housings are color-coded for safe and
reliable connections to all other mating type/polarizations, with raised ground
terminal standard.
Watertight and Grip Tite™ Safety
• Grip Tite™ flexible 6-finger clamp teeth holds well beyond all agency test pullout
forces.
• No internal clamps required.
• Available in all amperages.
H72 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 72
Polarization Guide – North American Ratings
UniGardGlobal Configuration Standards
250/440 to
265/460V
60 Hz
440-460V
60 Hz
> 50V
100 to
300 Hz
120/208
250V
277V
60 Hz
3Ø 600V
3ØY347/600V
125V
100
to
130 57/100
to
75/130
> 50
to
250 DC
380
50 Hz
to
440
60 Hz
220/380
50 Hz
to
250/440
60 Hz
> 50V
300
to 500 Hz
> 50V
300
to 500 Hz
> 50V
300 to
500 Hz
125/250V
5 WIRE 3P+N+G
4 WIRE 3P+G
3 WIRE 2P+G
h
12 1
2
3
4
5
6
7
8
9
10
11
380
to
415
> 250 DC
480V
3Ø 480V
3Ø 277/480V
250V
380V
to
415V
200/346
to
240/415
US US US
EUR
EUR
EUR
(spc.) 16a, 5w, 250v, 1h
RECEPTACLE
CONNECTOR
Catalog Numbering System
Configuration
It’s impossible to mismate different
voltages of the IEC 309-2 Standard
Devices.
• Device size determines amperage.
Each voltage grouping is a different size
so they are easily distinguishable for
compatibility.
All IEC 309-2 devices are color-coded.
Each voltage grouping has its own
distinct color coding for mating
compatibility.
• Every IEC 309-2 mating plug grounding
pin is a mirror image of the female
device.
Devices of differing voltages cannot be
mated to one another.
• The Female receptacles and connectors
have a “clock face” voltage polarization.
A “keyway” female housing notch is
always at 6 o’clock reference position.
Ground contact (sleeve) position on this
“clockface” establishes voltage
polarization. (ie. “7h”= 7 o’clock ground
sleeve position) Male pin positions are
mirror image.
Suffixes: Construction Options
Internal Protection IP67 = Watertight = W
IP44 = Splashproof = S
Polarization/Voltage 9= “9h” Clock Hour = 250 VAC, 3 phase
Amperage : 20, 30, 60, 100A or EURO 16, 32, 63, 125A
RS 430P9W
Plug, Connector, Receptacle, Inlet B
Poles & Wires : 2 p 3w, 3p4w, 4p5w
Rated Voltage Color Usage (N. Amer., R.O.W. Euro
110-130V Yellow No. Amer. and Euro.
208-250V Blue N. Amer. and Euro.
380-415V Red Euro.
500V + Black N. Amer. and Euro.
277/480V Red N. Amer.
277V Gray N. Amer.
125/250V Orange N. Amer.
250/440V Red Latin America
50-600V, 300/400Hz Green Euro. and N. Amer.
50-250VDC White Euro. and N. Amer.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H73
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 73
UniGardWatertight and Splashproof Pin and Sleeve Devices IP67 and IP44
WATERTIGHT IP67
Configuration Voltage/ Cable O.D.
Poles & Receptacle/ Plug/ Clock Color Plug Connector Range Receptacle* Inlet*
Wires Connector Inlet Hour Coding Inches
2P3W 4h 125 RS320P4W RS320C4W .57-.71 RS320R4W RS320B4W
2P3W 6h 250 RS320P6W RS320C6W .57-.71 RS320R6W RS320B6W
2P3W 5h 277 RS320P5W RS320C5W .57-.71 RS320R5W RS320B5W
2P3W 7h 480 RS320P7W RS320C7W .57-.71 RS320R7W RS320B7W
3P4W 12h 125/250 RS420P12W RS420C12W .57-.71 RS420R12W RS420B12W
3P4W 9h 3Ø250 RS420P9W RS420C9W .57-.71 RS420R9W RS420B9W
3P4W 7h 3Ø480 RS420P7W RS420C7W .57-.71 RS420R7W RS420B7W
3P4W 5h 3Ø600 RS420P5W RS420C5W .57-.71 RS420R5W RS420B5W
4P5W 9h 3ØY120/208 RS520P9W RS520C9W .57-.71 RS520R9W RS520B9W
4P5W 7h 3ØY277/480 RS520P7W RS520C7W .57-.71 RS520R7W RS520B7W
4P5W 5h 3ØY347/600 RS520P5W RS520C5W .57-.71 RS520R5W RS520B5W
IP44 Construction: No screw collars on male devices; female devices have flap covers only.
2P3W 4h 125 RS320P4S RS320C4S .57-.71 RS320R4S RS320B4S
2P3W 6h 250 RS320P6S RS320C6S .57-.71 RS320R6S RS320B6S
2P3W 5h 277 RS320P5S RS320C5S .57-.71 RS320R5S RS320B5S
3P4W 12h 125/250 RS420P12S RS420C12S .57-.71 RS420R12S RS420B12S
3P4W 9h 3ph.250 RS420P9S RS420C9S .57-.71 RS420R9S RS420B9S
4P5W 9h 3ph.120/208 RS520P9S RS520C9S .57-.71 RS520R9S RS520B9S
*See Page H81 for back box/mounting options.
SPLASHPROOF IP44
20 Amp
Liquidtight Conduit Adapter Kit
2LTK4C50 20A 3 & 4PW 1/2" NPT
3LTK4C75 20A 5W f" NPT
UL Listing E2630, E47956
UL Classification E205590
IP67 Shown
H74 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 74
UniGardWatertight and Splashproof Pin and Sleeve Devices IP67 and IP44
Configuration Voltage/ Cable O.D.
Poles & Receptacle/ Plug/ Clock Color Plug Connector Range Receptacle* Inlet*
Wires Connector Inlet Hour Coding Inches
2P3W 4h 125 RS330P4W RS330C4W .675-.91 RS330R4W RS330B4W
2P3W 6h 250 RS330P6W RS330C6W .675-.91 RS330R6W RS330B6W
2P3W 7h 480 RS330P7W RS330C7W .675-.91 RS330R7W RS330B7W
3P4W 12h 125/250 RS430P12W RS430C12W .675-.91 RS430R12W RS430B12W
3P4W 9h 3Ø250 RS430P9W RS430C9W .675-.91 RS430R9W RS430B9W
3P4W 7h 3Ø480 RS430P7W RS430C7W .675-.91 RS430R7W RS430B7W
3P4W 5h 3Ø600 RS430P5W RS430C5W .675-.91 RS430R5W RS430B5W
4P5W 9h 3ØY120/208 RS530P9W RS530C9W .675-.91 RS530R9W RS530B9W
4P5W 7h 3ØY277/480 RS530P7W RS530C7W .675-.91 RS530R7W RS530B7W
4P5W 5h 3ØY347/600 RS530P5W RS530C5W .675-.91 RS530R5W RS530B5W
IP44 Construction: No screw collars on male devices; female devices have flap covers only.
2P3W 4h 125 RS330P4S RS330C4S .675-.91 RS330R4S RS330B4S
2P3W 6h 250 RS330P6S RS330C6S .675-.91 RS330R6S RS330B6S
2P3W 5h 277 RS330P5S RS330C5S .675-.91 RS330R5S RS330B5S
3P4W 12h 125/250 RS430P12S RS430C12S .675-.91 RS430R12S RS430B12S
3P4W 9h 3ph.250 RS430P9S RS430C9S .675-.91 RS430R9S RS430B9S
4P5W 9h 3ph.120/208 RS530P9S RS530C9S .675-.91 RS530R9S RS530B9S
*See Page H81 for back box/mounting options.
WATERTIGHT IP67
SPLASHPROOF IP44
Liquidtight Conduit Adapter Kit
3LTK4C50 30A 3 & 4W d" NPT
3LTK4C10 30A 3 & 4W 1" NPT
3LTK4C75 30A 3 & 4W f" NPT
3LTK5C75 30A 5W f" NPT
3LTK5C10 30A 5W 1" NPT
30 Amp
UL Listing E2630, E47956
UL Classification E205590
IP67 Shown
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H75
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 75
UniGardWatertight Pin and Sleeve Devices IP67
Configuration Voltage/ Cable O.D.
Poles & Receptacle/ Plug/ Clock Color Plug Connector Range Receptacle* Inlet*
Wires Connector Inlet Hour Coding Inches
2P3W 4h 125 RS360P4W RS360C4W .937-1.375 RS360R4W RS360B4W
2P3W 6h 250 RS360P6W RS360C6W .937-1.375 RS360R6W RS360B6W
2P3W 5h 277 RS360P5W RS360C5W .937-1.375 RS360R5W RS360B5W
2P3W 7h 480 RS360P7W RS360C7W .937-1.375 RS360R7W RS360B7W
2P3W 3h 250DC RS360P3W RS360C3W .937-1.375 RS360R3W RS360B3W
3P4W 12h 125/250 RS460P12W RS460C12W .937-1.375 RS460R12W RS460B12W
3P4W 9h 3Ø250 RS460P9W RS460C9W .937-1.375 RS460R9W RS460B9W
3P4W 7h 3Ø480 RS460P7W RS460C7W .937-1.375 RS460R7W RS460B7W
3P4W 5h 3Ø600 RS460P5W RS460C5W .937-1.375 RS460R5W RS460B5W
4P5W 9h 3ØY120/208 RS560P9W RS560C9W .937-1.375 RS560R9W RS560B9W
4P5W 7h 3ØY277/480 RS560P7W RS560C7W .937-1.375 RS560R7W RS560B7W
4P5W 5h 3ØY347/600 RS560P5W RS560C5W .937-1.375 RS560R5W RS560B5W
*See Page H81 for back box/mounting options.
WATERTIGHT IP67
Liquidtight Conduit Adapter Kit*
6LTK5C75 60A 5W f" NPT
6LTK5C10 60A 5W 1" NPT
*Additional sizes available on request.
60 Amp
UL Listing E2630, E47956
UL Classification E205590
Note: All UniGard 60 & 100 Amp devices ship standard with IEC 309-1
configuration “pilot” pin/sleeves used for auxillary contact service.
Special construction without these pilot contacts is available.
(Add “XC” to end of cat. no.)
H76 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 76
UniGardWatertight Pin and Sleeve Devices IP67
Configuration Voltage/ Cable O.D.
Poles & Receptacle/ Plug/ Clock Color Plug Connector Range Receptacle* Inlet*
Wires Connector Inlet Hour Coding Inches
2P3W** 6h 250 RS3100P6W RS3100C6W RS3100R6W RS3100B6W
2P3W** 7h 480 RS3100P7W RS3100C7W RS3100R7W RS3100B7W
3P4W 12h 125/250 RS4100P12W RS4100C12W RS4100R12W RS4100B12W
3P4W 9h 3Ø250 RS4100P9W RS4100C9W RS4100R9W RS4100B9W
3P4W 7h 3Ø480 RS4100P7W RS4100C7W RS4100R7W RS4100B7W
3P4W 5h 3Ø600 RS4100P5W RS4100C5W RS4100R5W RS4100B5W
4P5W 9h 3ØY120/208 RS5100P9W RS5100C9W RS5100R9W RS5100B9W
4P5W 7h 3ØY277/480 RS5100P7W RS5100C7W RS5100R7W RS5100B7W
4P5W 5h 3ØY347/600 RS5100P5W RS5100C5W RS5100R5W RS5100B5W
**See Page H81 for back box/mounting options.
**Alternate vendor supplied item; construction features will vary from specs in this catalog. Full IEC approval and mating guaranteed.
Contact Technical Services for inlet/receptacle mounting components.
WATERTIGHT IP67
100 Amp
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
1.2650-
1.790
UL Listing E2630, E47956
UL Classification E205590
Note: All UniGard 60 & 100 Amp devices ship standard with IEC 309-1
configuration “pilot” pin/sleeves used for auxillary contact service.
Special construction without these pilot contacts is available.
(Add “XC” to end of cat. no.)
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H77
Liquidtight Conduit Adapter Kit
10LTK5C10100A 4W, 5W 1" NPT
10LTK5C125100A 4W, 5W 1.25" NPT
10LTK5C150100A 4W, 5W 1.50" NPT
For 4 wire and 5 wire plugs and connectors only, contact Technical
Services for 3 wire plug and connector conduit adapters. 100A 3 wire
plugs and connectors use PG48 backhandle thread.
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 77
North American Amperages – UniGardSeries Specifications
Performance - Electrical
Dielectric Voltage Withstand 3000 Volts for 1 minute (fixed devices)
2200 Volts for 1 minute (portable devices)
Maximum Working Voltage 600VAC/250 VDC (minimum creepage and clearances per UL 840)
Current Interrupting/Load Breaking Tested to 150% of full rated current for circuit interrupting
Temperature Rise Maximum 30°C rise at full rated current after 50 cycles overload at 150% rated load
at 0.75-pf
Endurance with Load 20 Amp: 5000 cycles; Load only
Per IEC309-1 Clause 21 30 Amp: 1000 cycles - Alternating load
60 Amp: 1000 cycles - Alternating load
100 Amp: 250 cycles - Alternating load
Performance - Mechanical
Cold (-25°C) Impact Resistance Per UL 1682 Section 34 and IEC 309-1 Clause 24
Cable O.D. Accommodation Round portable service cord from 0.57" O.D. through 1.79" O.D.
Terminal Identification In accordance with UL 1682 standards and IEC390-1: as L1-L2-L3-N-G
Cable Pull-Out Force Per UL 1682 Section 33 and IEC309-1 Clause 23
Product Identification Molded-in product trademark(s) and UL approved product label
Performance - Environmental
Moisture Resistance Per IEC309-1; Watertight flap/screw cover on IP67 devices or splashproof flap cover
on IP44 devices
Flammability All components V1 or better per UL94, V0 product ratings available
Operating Temperatures Maximum Continuous 90°C/194°F, Minimum -25°C/-13°F
Chemical Resistance Resists standard industrial hydrocarbons, acids, bases and solvents
Corrosion Resistance All metallic components stainless steel or nickel plated brass
Sleeve pressure rings of zinc plated steel
Materials
Housing Valox®
Contact Carriers Valox®
Cable Gland Nut Valox®
Cable Bushing Solid neoprene, onion ring type
O-Ring, Seals & Gaskets Solid neoprene
Pins & Sleeves Nickel plated brass
Sleeve Force Ring Zinc plated steel
Terminal Screws Nickel plated steel
Flap/Screw Cover Springs Stainless steel
EZ Clik™ Spring Stainless steel
Mounting Flanges Valox®
Cast Enclosures/Adapters 2 Layer electrostatic epoxy coated, copper-free aluminum enclosures
(Valox®Euro style NM also available)
(Valox®is a trademark of GE)
E2630
E47956
E205590
H78 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 78
UniGardSeries IP67 Dimensions
C
B
C
A
B
C
A
B
CA
B
C
A
Plug IP67 16/20A and 30/32A
A B C Cord Grip Range
Cat. No. inches mm inches mm inches mm inches mm
16/20A 2P3W 2.87 73 6.20 157 5.23 133 .570-.710 14-18
16/20A 3P4W 3.17 81 6.47 164 5.51 140 .570-.710 14-18
16/20A 4P5W 3.48 88 7.02 178 6.06 154 .570-.710 14-18
30/32A 2P3W 3.66 93 7.37 187 6.13 156 .675-.910 17-23
30/32A 3P4W 3.66 93 7.37 187 6.13 156 .675-.910 17-23
30/32A 4P5W 3.96 101 8.15 207 6.91 176 .675-.910 17-23
Plug IP67 60/63A and 100/125A
A B C Cord Grip Range
Cat. No. inches mm inches mm inches mm inches mm
60/63A 2P3W 4.41 112 9.68 246 7.67 195 .937-1.375 24-35
60/63A 3P4W 4.41 112 9.68 246 7.67 195 .937-1.375 24-35
60/63A 4P5W 4.41 112 9.68 246 7.67 195 .937-1.375 24-35
100/125A 3P4W 5.06 129 12.16 309 9.83 250 1.265-1.790 32-45
100/125A 4P5W 5.06 129 12.16 309 9.83 250 1.265-1.790 32-45
Connector IP67 16/20A and 30/32A
A B C Cord Grip Range
Cat. No. inches mm inches mm inches mm inches mm
16/20A 2P3W 2.87 73 6.75 171 2.97 75 .570-.710 14-18
16/20A 3P4W 3.17 81 7.04 179 3.28 83 .570-.710 14-18
16/20A 4P5W 3.48 88 7.62 194 3.75 95 .570-.710 14-18
30/32A 2P3W 3.66 93 8.04 204 4.04 103 .675-.910 17-23
30/32A 3P4W 3.66 93 8.04 204 4.04 103 .675-.910 17-23
30/32A 4P5W 3.96 101 8.83 224 4.03 102 .675-.910 17-23
Connector IP67 60/63A and 100/125A
A B C Cord Grip Range
Cat. No. inches mm inches mm inches mm inches mm
60/63A 2P3W 4.41 112 10.52 267 4.47 114 .937-1.375 24-35
60/63A 3P4W 4.41 112 10.52 267 4.47 114 .937-1.375 24-35
60/63A 4P5W 4.41 112 10.52 267 4.47 114 .937-1.375 24-35
100/125A 3P4W 5.06 129 12.80 325 5.06 129 1.265-1.790 32-45
100/125A 4P5W 5.06 129 12.80 325 5.06 129 1.265-1.790 32-45
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H79
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 79
B
I
AC
D
B
C
D
AI
UniGardSeries IP67 Dimensions
B
D
CA
B
D
CA
F
E
øG
øH
CLEARANCE
HOLE
Inlet IP67
16/20A and 30/32A
Inlet IP67
60/63A and 100/125A
F
E
øG
øH
CLEARANCE
HOLE
Receptacle IP67
16/20A and 30/32A
Receptacle IP67
60/63A and 100/125A
Inlet IP67 16/20A and 30/32A
ABCDEFGH
Cat. No. inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm
16/20A 2P3W 2.87 73 1.96 50 4.50 114 .75 19 3.87 98 3.87 98 3.0 76 .282 7.2
16/20A 3P4W 3.17 81 1.96 50 4.50 114 .75 19 3.87 98 3.87 98 3.03 77 .282 7.2
16/20A 4P5W 3.48 88 1.96 50 4.50 114 .75 19 3.87 98 3.87 98 3.5 89 .282 7.2
30/32A 2P3W 3.66 93 2.32 59 4.50 114 1.32 34 3.87 98 3.87 98 3.5 89 .282 7.2
30/32A 3P4W 3.66 93 2.32 59 4.50 114 1.32 34 3.87 98 3.87 98 3.5 89 .282 7.2
30/32A 4P5W 3.96 101 2.32 59 4.50 114 1.32 34 3.87 98 3.87 98 3.75 95 .282 7.2
Inlet IP67 60/63A and 100/125A
ABCDEFGH
Cat. No. inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm
60/63A 2P3W 4.41 112 3.44 87 4.50 114 1.68 43 3.87 98 3.87 98 3.5 89 .282 7.2
60/63A 3P4W 4.41 112 3.44 87 4.50 114 1.68 43 3.87 98 3.87 98 3.5 89 .282 7.2
60/63A 4P5W 4.41 112 3.44 87 4.50 114 1.68 43 3.87 98 3.87 98 3.5 89 .282 7.2
100/125A 3P4W 5.06 129 3.88 99 5.50 140 1.94 49 4.87 124 4.87 124 4.5 114 .282 7.2
100/125A 4P5W 5.06 129 3.88 99 5.50 140 1.94 49 4.87 124 4.87 124 4.5 114 .282 7.2
Receptacle IP67 16/20A and 30/32A
ABC DEFG H I
Cat. No. inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm Inches mm
16/20A 2P3W 2.87 73 2.32 59 2.97 .76 .94 24 2.36 60 2.36 60 2.56 65 .219 5.5 2.97 75
16/20A 3P4W 3.17 81 2.34 60 2.97 76 .94 24 2.36 60 2.36 60 2.56 65 .219 5.5 3.28 83
16/20A 4P5W 3.48 88 2.37 60 2.97 76 .94 24 2.36 60 2.36 60 2.56 65 .219 5.5 3.75 95
30/32A 2P3W 3.66 93 2.79 71 2.97 76 1.52 39 2.36 60 2.36 60 2.56 65 .219 5.5 4.04 103
30/32A 3P4W 3.66 93 2.79 71 2.97 76 1.52 39 2.36 60 2.36 60 2.56 65 .219 5.5 4.04 103
30/32A 4P5W 3.96 101 2.81 71 2.97 76 1.52 39 2.36 60 2.36 60 2.56 65 .219 5.5 4.03 102
Receptacle IP67 60/63A and 100/125A
ABC DEFG H I
Cat. No. inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm Inches mm
60/63A 2P3W 4.41 112 4.16 106 4.50 114 1.68 43 3.87 98 3.87 98 3.5 89 .282 7.2 4.47 114
60/63A 3P4W 4.41 112 4.16 106 4.50 114 1.68 43 3.87 98 3.87 98 3.5 89 .282 7.2 4.47 114
60/63A 4P5W 4.41 112 4.16 106 4.50 114 1.68 43 3.87 98 3.87 98 3.5 89 .282 7.2 4.47 114
100/125A 3P4W 5.06 129 4.52 115 5.50 140 1.94 49 4.87 124 4.87 124 4.5 114 .282 7.2 5.06 129
100/125A 4P5W 5.06 129 4.52 115 5.50 140 1.94 49 4.87 124 4.87 124 4.5 114 .282 7.2 5.06 129
H80 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 80
UniGardSeries Dimensions
B
C
A
E
D
øF
G
B cond.
B
C
AE
D
F
B
C
A
øE
D
F
G
B cond.
Junction Box
Angle AdapterAngle Enclosure
20° Angle Enclosures*
ABCD EF G
Cat. No. Conduit Size Use inches mm inches mm inches mm inches mm inches mm inches mm Inches mm
BE3-B75 f" 20A & 30A Devices 3.34 85 .97 25 1.12 28 4.12 105 4.00 102 .25 6 2.38 60
BE3-B100 1" 20A & 30A Devices 3.34 85 .97 25 1.12 28 4.12 105 4.00 102 .25 6 2.38 60
AE6-B125 1b" 60A Devices 5.13 130 1.41 36 2.05 52 5.62 143 5.00 127 .28 7 3.00 76
AE6-B150 1d" 60A Devices 5.13 130 1.41 36 2.05 52 5.62 143 5.00 127 .28 7 3.00 76
AE10-B150 1d" 100A Devices 7.05 179 1.81 46 2.68 68 6.88 175 5.50 140 .34 9 4.00 102
AE10-B200 2" 100A Devices 7.05 179 1.81 46 2.68 68 6.88 175 5.50 140 .34 9 4.00 102
* For use where there is no existing T&B Russellstoll JB series junction box installed. For 20/30A inlets, use 60A size.
20° Angle Adapters*
ABCD EF
Cat. No. Use inches mm inches mm inches mm inches mm inches mm inches mm
AA3 20A & 30A Devices 3.17 81 3.00 76 4.25 108 3.00 76 2.50 64 3.75 95
AA6L 60A Devices 5.23 133 4.00 102 5.43 138 4.88 124 3.44 87 4.81 122
AA10L 100A Devices 7.36 187 5.50 140 5.50 140 6.00 152 4.87 124 4.87 124
* To be used with JB series junction boxes or panel mount. For 20/30A inlets, use 60A size.
Rectangular Junction Boxes*
ABCD EF G
Cat. No. Conduit Size Use inches mm inches mm inches mm inches mm inches mm inches mm Inches mm
JB3-B75 f" 20A & 30A Devices 2.94 75 4.19 106 3.69 94 2.69 68 .25 6 2.38 60 1.25 32
JB3-B100 1" 20A & 30A Devices 2.94 75 4.19 106 3.69 94 2.69 68 .25 6 2.38 60 1.25 32
JB6-B125 1b" 60A Devices 4.00 102 5.63 143 4.94 125 3.81 97 .34 9 3.00 76 1.50 38
JB6-B150 1d" 60A Devices 4.00 102 5.63 143 4.94 125 3.81 97 .34 9 3.00 76 1.50 38
JB10-B150 1d" 100A Devices 5.50 140 5.50 140 4.25 108 6.75 171 .34 9 3.75 95 2.00 51
JB10-B200 2" 100A Devices 5.50 140 5.50 140 4.25 108 6.75 171 .34 9 3.75 95 2.00 51
* Unless otherwise specified, junction boxes are furnished with one conduit size at location B. To be used with AA series angle adapters.
For 20/30A inlets, use 60A size.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H81
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 81
UniGardInternational Amperages
16 Amp IP44
International Ratings
Common polarizations shown – other ratings
are available – contact Technical Services.
for 16A or 32A IP67 watertight ratings
(-W suffix) substitute -W instead of -S in
catalog number. ex. RS316P4W}
Configuration Voltage/ Cable O.D.
Poles & Receptacle/ Plug/ Clock Color Plug Connector Range Receptacle Inlet
Wires Connector Inlet Hour Coding Inches
2P3W 4h 110V RS316P4S RS316C4S .57-.71 RS316R4S RS316B4S
2P3W 6h 250V RS316P6S RS316C6S .57-.71 RS316R6S RS316B6S
3P4W 6h 380-415V RS416P6S RS416C6S .57-.71 RS416R6S RS416B6S
4P5W 6h RS516P6S RS516C6S .57-.71 RS516R6S RS516B6S
2P3W 4h 110V RS332P4S RS332C4S .675-.91 RS332R4S RS332B4S
2P3W 6h 250V RS332P6S RS332C6S .675-.91 RS332R6S RS332B6S
3P4W 6h 380-415V RS432P6S RS432C6S .675-.91 RS432R6S RS432B6S
3P4W 3h 380-440V Special Application – Contact Technical Services
4P5W 6h RS532P6S RS532C6S .675-.91 RS532R6S RS532B6S
2P3W 6h 250V RS363P6W RS363C6W .937-1.375 RS363R6W RS363B6W
3P4W 6h 380-415V RS463P6W RS463C6W .937-1.375 RS463R6W RS463B6W
4P5W 6h RS563P6W RS563C6W .937-1.375 RS563R6W RS563B6W
**2P3W** 6h 250V RS3125P6W RS3125C6W 1.265-1.790 RS3125R6W RS3125B6W
3P4W 6h 380-415V RS4125P6W RS4125C6W 1.265-1.790 RS4125R6W RS4125B6W
4P5W 6h RS5125P6W RS5125C6W 1.265-1.790 RS5125R6W RS5125B6W
**See Page H81 for back box/mounting options.
Euro color is “red ; devices supplied in North America will use “blue ” color (mating is not affected.)
**Alternate vendor supplied item; construction features will vary from specs in this catalog. Full IEC approval and mating guaranteed.
Contact Technical Services for inlet/receptacle mounting components.
UL Classification E205590
Note: All UniGard 63 & 125 Amp devices ship standard with IEC 309-1 configuration “pilot” pin/sleeves used for auxillary contact service.
Special construction without these pilot contacts is available.
(Add “XC” to end of cat. no.)
220-240/
380-415V
220-240/
380-415V
220-240/
380-415V
220-240/
380-415V
32 Amp IP44
63 Amp IP67
125 Amp IP67
See Page H74 for Conduit
Adapter Options
See Page H75 for Conduit
Adapter Options
See Page H76 for Conduit
Adapter Options
IP67 IP44
H82 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 82
International Amperages – UniGardSeries Specifications
Performance - Electrical
Dielectric Voltage Withstand 3000 Volts for 1 minute per IEC309-1, Clause 19
Maximum Working Voltage 690VAC/250 VDC (minimum creepage and clearances per IEC)
Current Interrupting/Load Breaking Tested to 125% rated current at 110% rated voltage per IEC309-1 clause 20.
Temperature Rise Maximum 50°C rise at rated current per IEC309-1
Clause 22, Table 8
Endurance with Load 16 Amp: 5000 cycles; Load only
Per IEC309-1 Clause 21 32 Amp: 1000 cycles - Alternating load
63 Amp: 1000 cycles - Alternating load
100 Amp: 250 cycles - Alternating load
Performance - Mechanical
Cold (-25°C) Impact Resistance Per IEC309-1 Clause 24; (-25°C) with 75cm drop
Cable O.D. Accommodation Round portable service cords from 14.5mm O.D. through 50mm O.D.
Terminal Identification In accordance with IEC309-1 standards; as L1-L2-L3-N-G
Cable Pull-Out Force In accordance with IEC309-1, Clause 23
Product Identification Molded-in product Trademark(s) and CE Mark on packaging
Performance - Environmental
Moisture Resistance Per 309-1; Watertight flap/screw cover on IP67 devices or flap cover on
IP44 devices
Flammability Per IEC 695-2-1; Housing glow wire tested to 650°C;
Contact carrier insert tested to 850°C
Operating Temperatures Maximum Continuous 90°C/194°F, Minimum -25°C/-13°F with impact
Chemical Resistance Resists standard industrial hydrocarbons, acids, bases and solvents
Corrosion Resistance All metallic components stainless steel or nickel plated brass
Sleeve pressure rings of zinc plated steel
UV Resistance External Thermoplastic components are UV stabilized
IP67 Series 2 is suitable for outdoor use
Materials
Housing Valox®
Contact Carriers Valox®
Cable Gland Nut Valox®
Cable Bushing Solid neoprene, onion ring type
O-Ring, Seals & Gaskets Solid neoprene
Pins & Sleeves Nickel plated brass
Sleeve Force Ring Zinc plated steel
Terminal Screws Nickel plated steel
Flap/Screw Cover Springs Stainless steel
EZ ClikSpring Stainless steel
Mounting Flanges Valox®
Cast Enclosures/Adapters 2 Layer Electrostatic epoxy coated, copper-free aluminum enclosures
(Valox®Euro style NM available)
E205590
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H83
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 83
UniGardSeries IP44 Dimensions
B
A
C
B
C
A
B
CA
D
B
C
I
A
D
F
E
øG
øH
CLEARANCE
HOLE
Inlet IP44
16/20A and 30/32A
Receptacle IP44
16/20A and 30/32A
Plug IP44
A B C Cord Grip Range
Cat. No. inches mm inches mm inches mm inches mm
16/20A 2P3W 2.26 58 6.20 157 4.76 121 .570-.710 14-18
16/20A 3P4W 2.52 64 6.47 164 5.04 128 .570-.710 14-18
16/20A 4P5W 2.85 73 7.02 178 5.58 142 .570-.710 14-18
30/32A 2P3W 2.85 73 7.37 187 5.58 142 .675-.910 17-23
30/32A 3P4W 2.85 73 7.37 187 5.58 142 .675-.910 17-23
30/32A 4P5W 3.13 80 8.15 207 6.36 162 .675-.910 17-23
Connector IP44
A B C Cord Grip Range
Cat. No. inches mm inches mm inches mm inches mm
16/20A 2P3W 2.18 55 6.53 166 3.07 78 .570-.710 14-18
16/20A 3P4W 2.43 62 6.83 173 3.33 85 .570-.710 14-18
16/20A 4P5W 2.81 71 7.41 188 3.79 96 .570-.710 14-18
30/32A 2P3W 2.81 71 781 198 3.79 96 .675-.910 17-23
30/32A 3P4W 2.81 71 781 188 3.79 96 .675-.910 17-23
30/32A 4P5W 3.09 79 8.62 219 4.17 106 .675-.910 17-23
Inlet IP44
ABCDEFGH
Cat. No. inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm
16/20A 2P3W 2.26 58 1.96 50 4.50 114 .75 19 3.87 98 3.87 98 2.38 60 .282 7.2
16/20A 3P4W 2.52 64 1.96 50 4.50 114 .75 19 3.87 98 3.87 98 2.38 60 .282 7.2
16/20A 4P5W 2.85 73 1.96 50 4.50 114 .75 19 3.87 98 3.87 98 2.38 60 .282 7.2
30/32A 2P3W 2.85 73 2.32 59 4.50 114 1.32 34 3.87 98 3.87 98 2.38 60 .282 7.2
30/32A 3P4W 2.85 73 2.32 59 4.50 114 1.32 34 3.87 98 3.87 98 2.38 60 .282 7.2
30/32A 4P5W 3.13 80 2.32 59 4.50 114 1.32 34 3.87 98 3.87 98 2.38 60 .282 7.2
Receptacle IP44
ABC DEFG H I
Cat. No. inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm Inches mm
16/20A 2P3W 2.18 55 2.11 54 2.97 76 0.94 24 2.36 60 2.36 60 2.38 60 .219 5.5 3.07 78
16/20A 3P4W 2.43 62 2.13 54 2.97 76 0.94 24 2.36 60 2.36 60 2.38 60 .219 5.5 3.33 85
16/20A 4P5W 2.81 71 2.17 55 2.97 76 0.94 24 2.36 60 2.36 60 2.38 60 .219 5.5 3.79 96
30/32A 2P3W 2.81 71 2.56 65 2.97 76 1.52 39 2.36 60 2.36 60 2.38 60 .219 5.5 3.79 96
30/32A 3P4W 2.81 71 2.56 65 2.97 76 1.52 39 2.36 60 2.36 60 2.38 60 .219 5.5 3.79 96
30/32A 4P5W 3.09 79 2.60 66 2.97 76 1.52 39 2.36 60 2.36 60 2.38 60 .219 5.5 4.17 106
H84 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 84
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H85
Washdown/ Light Marine
H
Russellstoll ®
Watertight – IP67
• “W” suffixes (UL Type 4X construction).
• Rugged thermoplastic housings resist
impact or abuse and provide excellent
corrosion resistance.
• Rugged VØ-5VA Flameproof Housings.
• Ideal for outdoor, wet, marine and
washdown applications.
• Unique industry-first circuit breaker
interlock.
• US: 20, 30, 60, &100 Amp sizes.
• International: 16, 32, 63, 125 Amp sizes.
Splashproof – IP44
• “S” suffixes (NEMA 3R construction).
• Suitable for indoor use where splashing
liquids and other contaminants may
interfere with electrical connections.
• Ideal for most heavy commercial
applications and light industrial
applications.
• US 20 & 30 & 60A ratings.
• International 16, 32 and 63A ratings.
Protection and Safety in Power
Delivery
• Red vertical ON indication.
• Lock on and Lock off positions.
Branch circuit load and operation protec-
tion, or switched-only version (shown).
Mount It Anywhere
• Swivel 3 or 4 point feet variable footprint
for flexible mounting.
• Fits in web of 8" I-Beams.
Switched-only Version
• Rugged UL listed switch.
• Proven performance components.
• Thru 600 VAC. 4p5w + auxiliary contacts
capable.
New IEC 309 Safety Interlock –
The UniGardDifference
The Only True Circuit Breaker Interlocked IEC 309
Receptacle – (Outlet)
• Circuit breaker integrated interlock mechanism.
• UL489 listed 22KAIC protection.
• Alternate trip ratings available.
• Auxiliary switch option.
E211951
E47955
Wire It Up, Sideways or Down
• Top, side, and bottom entry.
• Industry standard entry sizes.
Top & Bottom Top Side Entry
20/30 Amp 60/100 Amp All
OR
UniGardIEC 309 Safety Interlock
412031.H05 UNIGARD 3/5 3/14/03 6:50 PM Page 85
Bottom Conduit Entry –
Optional 30/60A
Location
5 Mounting
Points for
3 or 4 Tab
Mounting
UL94 Vø-5VA
Flame Rated
Housing &
External
Components
Auxiliary
Switch
and/or
Trip Frame
Ratings
Available
Sturdy Bright Red EZ
Handle (Vertical - on)
Lock-off & Lock-on
Positions
IP67 Color Coded
Flap Screw Cap
IP44 splashproof
also available
Voltage &
Polarization
Labeled and
Color Coded
Accepts UniGard
Plugs and all
Approved
IEC 309 lines
Adjustable Feet
fit any existing
mounting!
Gasketed UL Type-
4X Construction
Top or Side
Conduit Entry
UniGardIEC 309 Safety Interlock
External
DIN Rail
Hard-Points
Integral UL489 22KAIC
Circuit Breaker OR
Switched Interlocked
Receptacle
H86 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:51 PM Page 86
Internal Protection
Amperage : 20, 30, 60, 100A or EURO 16, 32, 63, 125A
RS 4 30 9W
Range Color Code Usage (N. Amer., R.O.W. Euro) 2p3w 3p4w 4p5w
110-130V Yellow No. Amer. / Euro. 4h 4h
208-250V Blue N. Amer. / Euro. 6h 9h 9h
380-415V Red Euro. 9h 6h/3h (spec) 6h
500V + Black N. Amer. / Euro. 5h 5h
277/480V Red N. Amer. (black-Euro) 7h 7h 7h
277V Gray N. Amer. 5h
125/250V Orange N. Amer. 12h
250/440V Red Latin America / N. Amer 11h 11h/3h
to 600V, to 400Hz Green N. Amer. / Euro. 2h 2h 2h
Contact T&B for other special polarizations.
New Russellstoll®UniGardIEC 309 Circuit Breaker Interlocked Receptacle
16/20A, 30/32A, 60/63A and 100/125A International and U.S. Ratings
IN ALL STANDARD VOLTAGE POLARIZATIONS:
Specifications for Any New or Replacement Project
2 options
available MI
Integral Circuit Breaker (UL231 & UL489) Power Outlet
> (replaces all Fused-Switched competitor “FMIR” or “MIF” series) (US amperage only)
Rotary Switched (UL508 & UL98) Manual Motor Controller Outlet
> (replaces all Switched-only competitor “MI” or “MIR” series) (All amperages)
Brand
prefix
- or -
“blank”
Device Type See above
MT
Suffixes: Construction Options
Poles & Wires : 2 p 3 w , 3 p 4 w, 4p5w
IP67 = Watertight = W
IP44 = Splashproof = S
Polarization/Voltage 9 = “9h” Clock Hour = 250 VAC, 3 phase
UniGardIEC 309 Safety Interlock
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H87
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:51 PM Page 87
Performance – Electrical
Dielectric Voltage 3,000 Volts
Withstand
Maximum Working 480 Volts RMS (circuit breaker version)
Voltage 600 Volts RMS (switch version)
Current Interrupting Certified for current interrupting at full
rated current and voltage.
Short-circuit Current Rating 10,000 RMS symmetrical amperes
Operations Mechanical: 10,000 cycles
Electrical: 6,000 cycles
HP Ratings (switch version) Complies with NEC 430-151 ratings.
Circuit Breaker UL Listed 22,000 AIC
Interrupting Rating
Performance – Mechanical
Cold (-35°C) Impact In accordance with UL 746C.
Resistance
Wiring Accommodations Suitable for metallic conduit. Conduit
entry locations at enclosure top and bottom
(60A & 100A top only).
Terminal Identification In accordance with UL, CSA and
IEC309 conventions.
Product Identification Identification, ratings and color-code in
accordance with UL, CSA and IEC309
requirements.
Lockout/Tagout ON and OFF lockout/tagout capability
at switch handle. Complies w/ OSHA
Reg. 29CFR 1910.147
Mounting External adjustable feet.
Performance – Environmental
Moisture Resistance Screw cap version: #UL type 4X, IP67 Flap cap
version: IP44
Flammability UL94-5VA & V0 classifications
Operating Temperatures Maximum Continuous: 60°C (140°F)
Minimum Continuous: -40°C (-40°F)
UV Resistance UV stabilized material
Chemicals Resists most standard industrial hydrocarbons,
acids, bases and solvents.
Materials
Enclosure (all exterior UL94-5VA/V0, UV stabilized, impact
components) modified Valox.
Contact Carrier Molded arc resistant UL94-V0 thermoplastic.
Gaskets Neoprene or EPDM
Contacts (sleeves) Nickel plated brass
Hardware (screws & Steel with zinc-plated blue chromate or
springs) nickel plating.
Approvals & Compliances
UL 508 & UL98 (switch version), UL 231 & UL489 (circuit breaker version),
UL 1682
CSA C22.2 No. 14, 182.1
IEC309-1, -2
Specifications: IEC 309 Interlocked Receptacles – North American Standards
5.1 (129) 7.2 (183)
A
B
9.3 (237)
C
A
B
7.2 (183)
14.6 (370)
H
G
D
E
F
I
MOUNTING DIMENSIONS (inches - mm)
16/20A 100/125A
30/32A 30A SWITCH
60/63A 60A 100A
DIM. SWITCH BREAKER BREAKER
D 5.5 - 140 5.5 - 140 5.5 - 140
E 10.0 - 254 15.2 - 387 15.2 - 387
F 5.5 - 140 5.5 - 140 6.0 - 152
G 8.0 - 203 8.0 - 203 8.0 - 203
H 7.5 - 191 12.8 - 324 12.8 - 324
I 8.0 - 203 8.0 - 203 8.5 - 215
OVERALL DIMENSIONS (inches - mm) OVERALL DIMENSIONS (inches - mm)
16/20A, 30/32A & 60/63A SWITCH VERSIONS 30A & 60A BREAKER AND 100A/125A
SWITCH & BREAKER VERSIONS
16/20A 30/32A 60/63A 30A 60A 100/125A
DIM. IP44 IP67 IP44 IP67 IP44 IP67 IP44 IP67 IP44 IP67 IP67
A 7.5 - 140 8.0 - 203 7.7 - 196 8.2 - 208 8.0 - 203 8.5 - 216 7.7 - 196 8.2 - 208 8.0 - 203 8.5 - 216 9.8 - 249
B 10.8 - 273 10.9 - 277 11.2 - 284 11.4 - 289 11.9 - 302 12.2 - 309 16.4 - 417 16.5 - 418 17.0 - 432 17.4 - 443 17.7 - 450
C 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.1 - 129 5.6 - 149
* 3-pt. and 4-pt. mounting positions available. 100A versions have 4-pt. mounting position only.
* Adjustable mounting feet, vertical or horizontal.
* slotted through holes for easier alignment.
UniGardIEC 309 Safety Interlock
H88 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Washdown/ Light Marine
H
Russellstoll ®
412031.H05 UNIGARD 3/5 3/14/03 6:51 PM Page 88
A New Thermoplastic option to
20/30A Standard Ever-Lok Plugs and
Connectors. 20 and 30A plugs will
mate directly to Standard Ever-Lok
receptacles, with a new EZTab
locking feature. For new installations,
specify Ever-Lok receptacles, with
DuraTite plugs and connectors.
Clamp or conduit options complete a
flexible value option for new and
existing installations.
Steel self-locking housings make the
Standard and Midget Ever-Loks
famous for their endurance in
punishing factory installations.
Clamp, bushing or hub fitting cable
entries are offered for both, with
Standard Ever-Lok available at 20,
30 and 50A over the15A Midget
Ever-Lok. Standard voltage
polarizations are maintained in these
lines through 480VAC.
The standard in portable welding
installations, from 30 to 100A.
Rugged aluminum housings and self-
locking upon insertion, HSE series
products are ideal for indoor factory
use. With unique “handle” designs, a
simple 1/8 turn counter-clockwise
releases plug for withdrawal. Switched/
fused or circuit breaker interlocks in
several configurations are also
offered. (see Automotive/Industrial
Interlock section).
Thermoplastic International Standard
309-2 or CEE-17 type connector
lines usage is growing in OEM,
export and standard performance
applications. The IP44 indoor use
style is “splashproof” when mated
and directly interchangeable with
other manufacturers. International
designations shadow U.S. ratings:
20/16, 30/32, 60/63 and 100/125.
IP44 devices have NO locking
features except flap covers, with
catalog numbers “S” or “SW” suffixes.
DuraTite
to 3P4W
20 & 30A
DuraTiteOverview and Product Comparison
Ever-Lok®
Standard &
Midget Series
to 3P4W
15 thru 50A
Heavy Service
Ever-Lok
to 4P4W
30 thru 100A
IEC (IP44)
to 4P5W
20 thru 100A
Defined
General Industrial
Lighting Connections
Indoor Welding Stations
Machinery/Tool Connections
Power Distribution Panels
Convenience Power
Battery Charging Equipment
Construction
Generator Set Panels
Portable Tools & Equipment
Limited Life Installations
Portable Lighting Equipment
Instrumentation
Portable Equipment
Critical Power Connections
Motor Power Connections
Critical Robotics Power
Test Equipment
Laboratory/Test Stations
OEM’s
Export Machinery
Critical Power Connections
International Indoor Usage
Transportable Equipment
Typical Application Groups
Russellstoll Line Selections for Indoor Applications
Any application where electrical connections need
protection from water and/or dust ingress to the contacts
or the wiring compartment.
Less credit cable sealing, but easier to use device locking
designs are employed.
Metal connectors are usually preferred, with thermoplastic
options increasing. Thermoplastic devices must withstand
normal industrial handling.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H89
Industrial and Commercial
H
Russellstoll ®
412031.H06 DTITE 3/5 3/14/03 6:58 PM Page 89
Non-Metallic Self-Locking Plugs, Connectors & Receptacles
Industrial Specification Grade Redefined
From our industry standard Ever-Lok series of plugs, connectors and
receptacles, Russellstoll has developed DuraTite™, the first non-metallic,
self-locking pin and sleeve power interconnection system. In 20 and 30
amp ranges, DuraTite™ mates with existing 15-30A Ever-Lok receptacles
already in use.
Industrial “Safety Grade” Construction
20 and 30 Amp plugs and connectors (600 VAC Max.)
Indoor industrial and heavy duty use.
Durable, Tough & Flame Safety Rated Housings
DuraVhousing material specially selected for hot or cold washdown
duty.
Flame Safe UL94-V0 rated housings.
Superior Performance in Corrosive Environments.
High Visibility yellow housings.
Safe & Reliable Power Connections: Pin & Sleeve,
Voltage Polarized
Long Life: Round, Self Cleaning, Constant Pressure Pin & Sleeve
Contacts, of Solid CDA 360 brass for long reliable electrical life.
More Power, Operates Cooler: large circular electrical contact area
allows more current flow with lower temperature rise.
Ground Pin Keyed for Voltage Polarization (O-ring seal).
Voltage Polarized for Safe Connection (U-ground) (pins shown with
optional O-ring seals).
Easy To Wire
“No twistoff” Locking Plugs: Integral Threaded Screw Collars and
Compression type Bushings make wiring a snap.
Fast Assembly and Wiring: “Drop-In” rear loaded interiors use no
assembly screws, versus 3-5 or more with other connectors. 30/50A
connectors use unique E-Z Titeexternal gland lock screw, also.
Set Screw Terminals: Are quick and easy to wire, with complete wire
capture in deep pin/sleeve barrels.
DuraTiteOverview
H90 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H06 DTITE 3/5 3/14/03 6:58 PM Page 90
Cat. Nos.
Plug Connector Receptacle- EverLok
Face
@250V Recep/
Amps Voltage Conn. DuraTite Ever-Lok DuraTite Ever-Lok
8013U1 8023U1
125 VAC 5P23U1LD 8153U1 5C23U1LD 8093U1 .625 8003U1 8083U1
8593U1 8683U1
5P23U2LD 8013U2 5C23U2LD 8023U2 .625 8003U2 8083U2
250 VAC 8153U2 8093U2
8593U2 8683U2
5P23U3LD 8013U3 5C23U3LD 8023U3 .625 8003U3 8083U3
277 8153U3 8093U3
8593U3 8683U3
5P23U4LD 8013U4 5C23U4LD 8023U4 .625 8003U4 8083U4
480 8153U4 8093U4
8593U4 8683U4
5P23U5LD 801345 5C23U5LD 8023U5 .625 8003U5 8083U5
600 8153U5 8093U5
8593U5 8683U5
5P23U0LD 8013 5C23U0LD 8023 .625 8003N 8083N
thru 600 (all) 8153 8093
8593 8683
125 VAC 5P33U1LD –– 5C33U1LD –– .700 N.A. N.A.
250 VAC 5P33U2LD –– 5C33U2LD –– .700 N.A. N.A.
277 VAC 5P33U3LD –– 5C33U3LD –– .700 N.A. N.A.
480 VAC 5P33U4LD –– 5C33U4LD –– .700 N.A. N.A.
600 VAC 5P33U5LD –– 5C33U5LD –– .700 N.A. N.A.
5P33U0LD 8015 5C33U0LD 8025 .700 8005N 8030N
thru 600 (all) 8155 8095
8656 8646
125/250 VAC 5P24U1LD –– 5C24U1LD –– .625 N.A. N.A.
250- 3ø VAC 5P24U2LD –– 5C24U2LD –– .625 N.A. N.A.
480 3ø VAC 5P24U4LD –– 5C24U4LD –– .625 N.A. N.A.
347/600V 5P24U5LD –– 5C24U5LD –– .625 N.A. N.A.
5P24U0LD 8018 5C24U0LD 8028 .625 8008 8084
thru 600 (all) 8158 8098
8594 8684
125/250 VAC 5P34U1LD –– 5C34U1LD –– .750 N.A. N.A.
250 3ø VAC 5P34U2LD –– 5C34U2LD –– .750 N.A. N.A.
480 3ø VAC 5P34U4LD –– 5C34U4LD –– .750 N.A. N.A.
347/600V 5P34U5LD –– 5C34U5LD –– .750 N.A. N.A.
5P34U0LD 8014 5C34U0LD 8024 .750 8004 8031
thru 600 (all) 8154 8094
8597 8687
8657 8647
3P4W
20A
(10A,
600V)
Std. I.D.
Bushing:
Plug/
Conn.*
2P3W
20A
2P3W
30A
3P4W
30A
(20A,
600V)
Notes:
DuraTite plugs and connectors will mate but not lock to metal plugs and connectors referenced above. DuraTite will lock to existing metal receptacles, from Standard
EverLok line.
Option: O-Ring sealed interiors also available— change suffix to “LW”
DuraTiteOrdering Information
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H91
Industrial and Commercial
H
Russellstoll ®
412031.H06 DTITE 3/5 3/14/03 6:58 PM Page 91
Specifications
Spring blade contact designs offer point contact only, with
minimal mechanical support in receptacles. Higher heat is
generated in use as contacts loosen with age and dirt
accumulation, resulting in failures. Exposed blade contacts
can easily be damaged.
Pin & Sleeve design allows higher current flow at cooler
temperatures due to the large circular contact area. Sleeves
act as retainers for the pins making a reliable connection.
Shrouded pins & sleeves are protected from damage and
casual access. Locking screw collars provide for a reliable,
long lasting connection.
Pin & Sleeve
Bladed Plug & Receptacle Pin & Sleeve Connector & Plug
Spring Contacts Blades
Shrouds
Sleeve Pin
Locking Screw Collar
Performance – Electrical
Dielectric Voltage 3,000 Volts
Withstand
Max. Working 6000 volts RMS (minimum
Voltage creepage and minimum clearance
per UL 840)
Circuit Interrupting/ UL listed and CSA certified for
Load Breaking circuit interrupting at full rated
current.
Temperature Rise Max. 30°C temperature rise at full
rated current after 50 cycles of
overload at 150% rated current at
.75-PF.
Horsepower Per NEC 430-151 ratings
Performance – Mechanical
Impact Resistance Per UL 1682 Paragraph 34
Cord Round portable service cords. 10
Accommodation standard diameters from .405" to
1.00", custom sizes to spec
Terminal In accordance with UL1682
Identification
Cable Pull Out In accordance with UL1682
Force
Product Identification label and molded in
Identification name
Performance – Environmental
Moisture Per UL1682 Paragraph 49. Flap
Resistance cover on receptacle, O-Rings
optional on all pins, sleeves, and
interiors. Watertight interiors with
optional O-rings. Meets require-
ments for NEMA 3R/12 & IP44.
Flammability V0 or better per UL94
Operating Maximum Continuous: 95°C /
203°F
Temperatures Minimum: -40°C / -40°F w/o impact
Chemicals Resists standard industrial hydro-
carbons, acids, bases and
solvents.
Material
Contact Carrier Molded arc resistant UL94-V0
Interior phenolic thermoset
Housing, Gland Nuts DuraV™ UL94-V0, High Impact
Screw Collar Rings Thermoplastic
O-Rings Buna-N (Nitrile)
Contacts: Pins Brass CDA 360
& Sleeves
Terminals Brass CDA 360
All Hardware Stainless Steel
Gland Friction 20 Amp - Nylon
Washer 30 & 50 Amp - Aluminum
Cable Clamp Bushing Neoprene
Approvals
®
DuraTiteSpecifications
H92 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H06 DTITE 3/5 3/14/03 6:58 PM Page 92
Amps A* B C*
20 Amp Inches 3.87 2.16 2.75
mm 98.3 54.9 69.9
30 Amp Inches 5.38 2.38 4.16
mm 136.6 60.5 105.7
A
B
D
E
Plugs Connectors
* Note – Dimensions will vary slightly with assembly.
Receptacles
DuraTite mates and locks to
standard EverLok (see page H89).
Cast Aluminum Cast Brass
Single 3711A 3731
Double 3712A 3732
Cast Aluminum Cast Brass
3678A 3678B
Conduit Boxes (For Surface Mounting) 45° Angle Adapter
Note: f" NPT Hole Std.
Additional Accessories Are Available. Consult Factory.
Accessories
Additional Boxes and Accessories Available: EverLok Section
Catalog Number 3711A Catalog Number 3712A Catalog Number 3678A
DuraTiteDimensions and Accessories
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H93
Industrial and Commercial
H
Russellstoll ®
412031.H06 DTITE 3/5 3/14/03 6:58 PM Page 93
Standard: 10-50 Amp, Maximum 600 VAC or 250 VDC
Heavy Service: 30-100 Amp Maximum 480 VAC or 250 VDC
Midget: 10-20 Amp Maximum 250 VAC or 250 VDC
Ever-Lok®Locking Connections – Overview
When an Ever-Lok connection
is made, it is a mechanical
attachment which will not pull
apart unless it is unlocked by
hand.
To install, line up the tabs
and plug it straight in.
External buttons or ribs lock
with the mating internal
housing automatically. When
an Ever-Lok plugs in, it
stays in. Locked housings
do the work so Ever-Lok
contacts can carry the load!
A firm grip and short a
counter-clockwise reverse
twist release locking for
easy removal.
1. Automatic Locking – Automatic locking feature
mechanically attaches the plug casing to the receptacle
or connector, and eliminates strain on electrical contacts.
2. Positive Grounding – Casings are positively grounded
by means of phosphor bronze ground straps integral with
ground contacts. Equipment grounding is secured by
separate set of contacts which “make” first and “break”
last as required by UL.
3. Dust-Proof – On clamp type plugs and connectors a
washer is provided in each cap to be forced over the
cord. This serves as a shield to prevent metal particles,
dust, etc., from entering the interiors of plugs and
connectors.
Bushing type plugs and connectors are furnished with a
gland nut and neoprene cable bushing gland to exclude
dust and moisture. A formed glide washer is also
provided to facilitate tightening of the gland nut.
Receptacle covers are sealed to boxes by gaskets and
have hinged flaps which are gasket-lined and equipped
with strong springs to keep them closed and dust-tight.
4. Steel-Clad – Plugs and connectors are plated steel.
Plugs have encased locking spring in machine
assembled non-separable housings.
5. Cord Grip – Plugs and connectors are provided with
adjustable cord grips, preventing strains on connections.
6. Contacts – Contacts are precision made, self-wiping and
self-aligning brass and nickel plated brass.
7. Unit Assembly Contacts and terminals are permanently
assembled in arc-resisting composition body permitting
removal of interior as a unit for wiring. All connections are
entirely enclosed, thus avoiding accidental short circuits
and tampering by inexperienced personnel.
8. Handles Lined – Shell handles have a HDPE liner to
contain stray wire ends.
9. Interiors – All interiors are molded arc-resisting
composition.
Design Features
Automatic Locking
Feature Contacts
Molded
Arc-Resisting
Interiors
Steel Clad
Housings
Cord Grip
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H95
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 95
Female Receptacle
250 VAC Receptacle with Box
Rating Rating Only w/Flap Cover^ FSWS-62* 2-Gang‡
20 Amp, 125VAC For Replacement For Replacement For Replacement
15 Amp, 250VAC Only Only Only
10 Amp, 600VAC 8003N 8083N 8128N
15 20 Amp, 125V 8003U1 8083U1 8128U1
Amp 15 Amp, 250V 8003U2 8083U2 8128U2
15 Amp, 277VAC 8003U3 8083U3 8128U3
15 Amp, 480VAC 8003U4 8083U4 8128U4
15 Amp, 600VAC 8003U5 8083U5 8128U5
30 30 Amp, 250V For Replacement For Replacement For Replacement
Amp 20 Amp, 600VAC Only 8005N Only 8030N Only 8131N
20 Amp, 125V
15 10 Amp, 250V 8008 8084 8129
Amp 15 Amp, 250VAC
10 Amp, 600VAC
30 20 Amp, 600VAC w/FD box w/FD box
Amp 30 Amp, 250V 8004 8031 8132
50 50 Amp, 250VAC w/FD box w/FD box
Amp 30 Amp, 250V 8304 8331 8334
30 Amp, 600VAC
3P4W 2P3W
Notes:
^ For FS, FD, FSWS, FDWS and similar conduit fittings.
** Receptacle with box and cover
** Provided with FDWS62 Box
Two gang receptacles can also be provided in mixed configurations
including NEMA bladed, etc. Consult Technical Services.
Male Inlets (Reversed Contacts Service): use receptacle mountings but accept
standard female connector.
Horse Power Ratings
dHp, 1 phase, 230VAC
1 Hp, 3 phase, 115VAC
Note: Standard EverLok receptacles also accept DuraTite™ plugs.
Ever-Lok®Locking Connections – Standard Ordering Information
Standard Service Female Receptacles
H96 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 96
Male Inlet
Male Inlet With Box** Mating Plugs & Connectors
For Replacement For Replacement
Only Only
8143 8143D
8143U1 8143U1D
8143U2 8143U2D
8143U3 8143U3D
Consult Factory Consult Factory
Consult Factory Consult Factory
8146 Consult Factory
8144 8144D
8147 8147D
8374 8374
Reverse Service Male Receptacles* Plugs & Connectors
Specifications:
Receptacle Housing – Plated steel. Receptacle with cover only; furnished with 6-32 mounting screws. For mounting on switch box or outlet box, use adapter plate 8091A
see page H104.
Back Boxes – Cast aluminum, epoxy powder coat finish. Flap and screw caps aluminum, corrosion-resistant copper-free alloy or steel, CAD plated.
Plug – All cable entry styles of plugs with equivalent ratings fit above receptacles.
Conduit Boxes – Type FSWS-62 or FDWS-62 standard, cast aluminum. Additional boxes available, see page H103.
Gang Type – Can be furnished in gang or tandem units and in combination with other FS and FD devices. See page H103.
Outlets – Unless otherwise specified, furnished with one f" outlet. Additional outlets charged extra, specific size and location. Consult Technical Services.
Contacts – “N” suffix indicates nickel plated neutral, used on 2p3w non-polarized devices.
Ever-Lok®Locking Connections – Standard Ordering Information
See Pages H98 & H99 for offering
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H97
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 97
Ever-Lok®Locking Connections – Standard Ordering Information
New! DuraTiteline offers thermoplastic performance and EverLok interface. See page H89.
2P3W
3P4W
Notes for Plugs and Connectors:
Cable Bushing – oil resistant, neoprene cable bushing regularly furnished with hole size as
listed. Other hole sizes available at no extra cost, when specified on order. See page H123 for
available sizes. Bushing type plugs and connectors can be furnished with adapters to
accommodate rigid conduit or standard connectors for armored and nonmetallic cable or
flexible conduit. See page H123.
Nin catalog number refers to Nickel plated Neutral Pin, replace. Ex: 8013 with 8013N.
Note: Special construction options for EverLok plugs include control “Dummy Plugs” for
press lockout function. Consult Technical Services. (8158-F22863)
** Hub with clamp added at size.
** Accommodates rigid conduit or standard connectors for armored and
nonmetallic cable or flexible conduit.
15
Amp
30
Amp
15
Amp
Male Plugs
Max Cable
250 VAC Cable Bushing Conduit
Rating Rating Clamp Type Dia. Bushing Type Hole Dia. Hub Type* Size
20 Amp, 12Z5VAC
15 Amp, 250VAC 8013N d" 8153N e" 8593N d"
10 Amp, 600VAC 8593CTN** d"
20 Amp, 125V 8013U1 d" 8153U1 e" 8593U1 d"
8593U1CT* d"
15 Amp, 250VAC 8013U2 d" 8153U2 e" 8593U2 d"
15 Amp, 277VAC 8013U3 d" 8153U3 e" 8593U3 d"
15 Amp, 480VAC 8013U4 d" 8153U4 e" Consult Factory
15 Amp, 600VAC 8013U5 d" 8153U5 e" Consult Factory
30 Amp, 250V 8015 e" 8155 e" 8656 f"
20 Amp, 600VAC
20 Amp, 125V
10 Amp, 250V 8018 d" 8158 W" 8594 d"
15 Amp, 250VAC
10 Amp, 600VAC
30 20 Amp, 600VAC 8014 e" 8154 f" 8597 d"
Amp 30 Amp, 250V 8657 f"
50 50 Amp, 250VAC 8314-S f" 8354 1" 8396 d"
Amp 30 Amp, 250V 8314 1a" 8397 f"
30 Amp, 600VAC
H98 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 98
Max. Cable
Cable Bushing Conduit
Clamp Type Dia. Bushing Type Hole Dia.* Hub Type** Size
8023N d" 8093N e" 8683N/8683CTN* d"
8023U1 d" 8093U1 e" 8683U1/8683U1CT* d"
8023U2 d" 8093U2 e" 8683U2 d"
8023U3 d" 8093U3 e" 8683U3 d"
Consult Factory Consult Factory Consult Factory
Consult Factory Consult Factory Consult Factory
8025 e" 8095 e" 8646 f"
8028 d" 8098 W" 8684 d"
8024 e" 8094 f" 8687/8687CT* d"
8647 f"
8324S f" 8394 1"
8386 d"
8387 f"
Ever-Lok®Locking Connections – Standard Ordering Information
New! DuraTiteline offers thermoplastic performance and Everlok interface. See page H91.
Female Connectors
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H99
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 99
Single Receptacle
Flanged Panel
Duplex Receptacle
Rating Receptacle Only with Back Box Mount Recp. Receptacles Only with Back Box
10 Amp, 250VDC 8703 8753 8943 8733 8773
2P 3W 20 Amp 250VAC*;
20 Amp 125VAC 8703U1 8753U1 8943U1 8733U1 8773U1
15 Amp 250VAC 8703U2 8753U2 8943U1 8733U2 8773U2
3P 4W 10 Amp 125VDC 8704 8754 8944 8734 8774
20 Amp 250VAC**
4P 5W 10 Amp 125VDC 8705 8755 8945 8735 8775
20 Amp 250VAC**
Ever-Lok®Locking Connections – Midget Ordering Information
Notes:
*dHP., 1 Phase - 230VAC
** dHP., 1 Phase - 230VAC
1 H.P., 3 Phase - 115VAC
Specifications:
Receptacle Housing – Heavy gauge steel, plated.
Back Boxes – Type FSWS-62 standard, cast aluminum. Additional boxes available, see page H103.
Gang Type – can be furnished in gang or tandem units and in combination with other FS and FD devices. See page H103.
Outlets – Standard, one f" top or bottom, additional outlets, see boxes listed on pages 103, charged extra.
Plug and Connector Housings – Steel, plated.
Cable Diameter:
Clamp Type – .500" max. cable diameter.
Bushing Type:
2P3W – .563" diameter standard
3P4W – .281" diameter standard
4P5W – .594" diameter standard
Cable Bushing – Oil resistant, neoprene cable bushing regularly furnished with hole size as listed. Other hole sizes available at no extra cost, when specified on order.
See page H123 for available sizes.
Standard Service Female Receptacles
H100 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 100
Ever-Lok®Locking Connections – Midget Ordering Information
^ Plugs and connectors are also available as bushing or hub type similar to those in Standard Everlok.
Please consult factory for ordering information.
Clamp Type^ Clamp Type^ Male Flanged Clamp Type^ Clamp Type^
Male Plug Female Connector Panel Mount Female Plug Male Connector
8713 8723 8943R 8713R 8723R
8713U1 8723U1 8943U1R 8713U1R 8723U1R
8713U2 8723U2 8943U2R 8713U2R 8723U2R
8714 8724 8944R 8714R 8724R
8715 8725 8945R 8715R 8725R
Standard Service Plugs & Connectors Reverse Service
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H101
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 101
Clamp Type Bushing Type Hub Type
Size A B C D A B C D A B C D
Standard
15 - 20 A 3.125" 1.750" 3.187" 0.500" 3.250" 1.750" 3.375" 0.750" 3.125" 1.750" 3.187" 0.500"
30 Amp 3.437" 2.125" 4.250" 0.625" 3.750" 2.125" 4.500" 1.125" 3.500" 2.125" 4.250" 0.750"
50 Amp 4.750" 2.125" 4.750" 1.125" 4.875" 2.125" 4.875" 1.125" 4.500" 2.125" 4.625" 0.750"
Midget 2.875" 1.440" 2.875" 0.500" 3.000" 1.440" 3.000" 0.625" 2.875" 1.440" 2.875" 0.500"
Ever-Lok®Locking Connections – Dimensions
Standard Service Reverse Service
Size A B C D A B C D
Standard
10 Amp
15 Amp .875" 1.375" 2.375" 2.313" .875" 2.000" 1.750" 2.937"
20 Amp
30 Amp .875" 1.500" 2.875" 2.937" .875” 1.500" 2.875" 2.937"
50 Amp 1.470" 1.875" 2.125" 2.937" 1.470" 1.875" 2.125" 2.937"
Midget .687" 1.810" 1.280" NA .687" 1.810" 1.280" NA
Female Receptacles & Reverse Service
W/out Box w/Box FSWS-62 w/Box FDWS-62
2.812"
4.312"
1.875"
3.25"
A
C
B
6 - 32
.25"
AD
Midget Duplex
Plugs & Connectors
Clamp Type Bushing Type Hub Type
Plug Connector Plug Connector Plug Connector
H102 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 102
No. of Gangs Type Cast Aluminum Cast Brass *Overall Dimensions
FS 3701A 3721 4.12" x 2.62" x 2.31"
Single FD 3711A 3731 4.12" x 2.62" x 2.94"
DSFD 3781A 3782 4.12" x 3.62" x 4.12"
Two FS 3702A 3722 4.12" x 5.5" x 2.25"
FD 3712A 3732 4.12" x 5.62" x 2.87"
Conduit Entries
Cat. No. Top Bottom
FSWS-62 f" NA
FDWS-62 f" NA
FDWS-622 f" f"
FDWS-63 1" NA
FDWS-633 1" 1"
Ever-Lok®Locking Connections – Accessories
Mounting options for Midget and Standard Everlok
Type FS (shallow) & Type FD (deep)
Aluminum boxes have 6-32 cover mounting holes tapped to accommodate all FS and FD cover assemblies.
Brass boxes have 10-24 cover mounting holes tapped to accommodate all FS and FD cover assemblies.
Single Gang Two Gang DSFD
Notes:
When type FD devices are to be mounted in boxes, type FD boxes should be used.
FS boxes will not accommodate FD devices.
Mounting – all the above boxes are for surface mounting. For flush mounting see
page H104.
Boxes – Cast brass, natural finish. Cast aluminum, corrosion resistant
copper-free alloy, epoxy powder coat finish.
* Dimensions are overall exclusive of conduit pads and mounting lugs.
Conduit Entries – unless otherwise specified, furnished with one .75" outlet per gang,
top or bottom. Additional conduit entries available – see price list. Specify size and
location.
Maximum Conduit – FS and FD: 1", one per gang top and bottom and one each side.
DSFD: one 1.5" or two .5" top and bottom.
Cast iron available on special order – consult factory.
Type FSWS and FDWS (with mounting shelf for box-mounted devices)
Aluminum Die-Cast Boxes with cover mounting holes tapped for 6-32 screws to accommodate all FS and FD cover assemblies.
Notes:
Boxes – Aluminum die-cast, corrosion-resistant, copper-free alloy,
epoxy powder coat finish.
Conduit Entries – standard as listed.
Mounting – all of the above boxes are for surface mounting.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H103
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 103
The addition of this adapter sub-plate will permit the use
of Ever-Lok conduit box-type receptacles in switch
boxes or outlet boxes with raised covers, as listed. Used
on standard (deep) stamped metal conduit boxes.
Adapts two hole to four hole patterns.
Cast Aluminum 8091A
Covers Standard FS/FD box openings:
Adapter Flush Frames*
No. of Gangs Cast Aluminum Cast Brass Overall Dimensions
13671A 3681 5" x 3.5"
23672A 3682 5" x 6.5"
Ever-Lok®Locking Connections – Accessories
Blank Cover*
Cast Aluminum 3679A
Cast Brass 3679B
45° Angle Adapter*
Mounts to any FS/FD box.
Cast Aluminum 3678A
Cast Brass 3678B
* Furnished complete with gasket and screws.
Materials: Cast aluminum, corrosion-resistant, copper-free alloy, epoxy
powder coat finish. Cast brass, natural finish.
Adapter Sub-Plate
Flush Wall Mounting Extension*
Cast Aluminum 3677A
Cast Brass 3687
H104 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 104
Ever-Lok®Locking Connections – Accessories
Type FS & FD
Single Gang Multiple Gang
4.12"
.31"
4.12"
2"
2.62"
3.62"
3.18"
MTG
.31"
2 MTG. Holes
4.37"
MTG
DSFD
Type FSWS & FDWS Blank Cover
Flush Mounting Extension 45° Angle Adapter
AB
FS FD FS FD
2-Gang 6.50" 6.50" 5.50" 5.62"
3-Gang 11.25" 9.37" 10.37" 8.50"
4-Gang 14.12" 12.25" 13.25" 11.37"
Multiple Gang Dimensions
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H105
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 105
Cable Bushings
Hole Diameter Size 1 Size 2 Size 3
for Cable Midget Everlok STD. 15 AMP 20, 30 & 50 Amp
.250" MG0
.313" SG05
.375" SG1 JG31
.438" MG15 SG15
.500" MG2 SG2 JG32
.531" SG2A
.563" MG25 SG25 JG325
.594" MG2B SB2B
.625" SG3 JG33
.688" SG3A
.750" SG4 JG34
.875" JG35
1.000" JG36*
1.125" JG361**
Ever-Lok®Locking Connections – Accessories
Combination Gland Nut and Cable Clamp Conduit Adapters
Size 2
Cable Bushing
Size 3
Cable Bushing
Provides extra clamping protection in hard service
applications. Relieves terminals and rubber gland of all
cable strain.
Adapter tapped with NPT thread to accommodate
armored and non-metallic cable or flexible conduit.
Notes:
Material – cast aluminum, corrosion-resistant, copper-free alloy, cast brass, epoxy powder
coat finish and cast brass.
Material – oil resistant neoprene.
Size 3 Cable Bushing:
**Style for Maximum Cable only.
**Special minimum wall style.
Notes:
Bushing Specials available at time of order.
When standard plugs or connectors are required to be furnished with one or more of the above accessories, add the suffix and catalog number of the accessory selected to the catalog
number of the plug or connector. Complete list price is the total of the list price of the device plus the list price of the accessory.
EXAMPLE — Catalog No. SKP3G with adapter tapped c" would be Catalog No. SKP3G/JG31.
Plug or Cast Cast Tapped
Connector Aluminum Brass Hole
Size Cat. No. Cat. No. NPT
15 Amp FSA11 FSA11B .5"
FSA12 FSA12B .75"
30 Amp FSA21 FSA21B .5"
50 Amp FSA22 FSA22B .75"
FSA23 FSA23B 1"
Plug or Cast Cast Max.
Connector Aluminum Brass Cable
Size Cat. No. Cat. No. Dia.
10 Amp 3905 3905B .62"
20 Amp 3906 3906B 1.12"
30 Amp
H106 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 106
Industrial and Commercial
H
Russellstoll ®
Heavy Service Ever-Lok®– Overview
Heavy Duty Automatic Locking Receptacles, Plugs & Connectors
30-100 Amp, 480VAC / 250VDC
Design Features
Automatic locking features makes plug
casing mechanically fast to receptacle or
connector. Provides positive secure
connections under the most severe
conditions of shock and vibration.
Twist of the wrist instantly disengages the
plug when required (counter-clockwise a
turn).
Durable cast aluminum, corrosion-
resistant copper-free alloy, epoxy
powder coated finish housings.
Easy 60A bturn handle removal simplifies
and speeds up wiring.
(Combination conduit adapter thread/
clamp assembly included)
Molded arc-resisting composition interiors with
machined, full floating, self-aligning contacts.
Safety polarized interiors that can only be
assembled in the correct position.
Heavy Service EverLok components stay plugged-in so your
portable equipment stays on. The industrial standard for
portable welders and other industrial equipment locks in
place automatically at insertion – no screw collars to bother
with. With its contoured handle, an easy counter-clockwise
twist releases the plug for withdrawal, even under full-rated
load / circuit-interrupting conditions.
Simple and rugged, the Heavy Service EverLok self-locking
system sets the standard for easy access in facilities,
welding and industrial equipment use. All standard
receptacle configurations are available, as well as reversed
contacts – service options.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H107
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 107
Industrial and Commercial
H
Russellstoll ®
Current Rating Bushing Max. AWG Size
30 g" #8, -7 strand or flexible
60 1i" #4, -7 strand or flexible
100 1d" #2, -7 strand or flexible
HSF Series
Configuration Basic Receptacle HSA Series*
30 Amp 2P, 3W 8407 8443 HSF8403 8403
3P, 4W 8408 8444 HSF8404 8404
60 Amp 2P, 3W 8417 8453 HSF8413 8413
3P, 4W 8418† 8454 HSF8414 8414
100 Amp 3P, 4W 8428-72 8464-72 HSF8424-72 8424-72
Current Rating Std. Size Max. Size
30 1" 1b"
60 1" 1"
100 2" 2"
Cable Conduit Adapters: see page H112.
†Note: 8418 or F27194 Automotive 480VAC Version Plug.
Outlet Location: Standard Series
30 & 60
Amp
100 Amp
Box is square and
may be rotated to
bring outlets into
desired position.
Note:
Reverse service available by adding “R” suffix to catalog number. Solder lugs on 100
amp only.
Connectors – can be furnished with conduit adapters to accommodate rigid conduit
or standard connectors for armored and non-metallic cable or flexible conduit.
See page H112.
* Can be furnished with 45° angle adapter when specified on order. Add suffix -45 to
catalog number.
Flap Covers are standard on all receptacles.
B Std.
AC
D
B Std.
A
D
Heavy Service Ever-Lok®– Ordering Information
Plugs Connectors Receptacles
Std. Cable Bushing (see page H106 for other bushings) Conduit Size
H108 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 108
Industrial and Commercial
H
Russellstoll ®
Mounting Current Rating
Style To Order Use: 30 Amp 60 Amp 100 Amp
Standard Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle*
Series + + + +
HSA
Vertical or Square JB3 JB6 JB10
Mount Box 1" Std. Conduit Size 1d" Std. Conduit Size 2" Std. Conduit Size
++ + +
Angle JAA3 (20°) JAA6-AB6 (20°) JAA10 (20°)
Adapter or or or
JAA3-45 (45°) JAA6-45 (45°) JAA10-45 (45°)
Series Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle*
HSR ++ + +
Straight
Vertical Mount JB3 JB6 JB10
Box 1" Std. Conduit Size 1d" Std. Conduit Size 2" Std. Conduit Size
++ + +
Straight JRA3 JRA6-AB6 JRA10
Adapter
Series Receptacle Basic Receptacle* Basic Receptacle* Basic Receptacle*
HSB ++ + +
30° Angle JAAB3 JAAB6 JAAB10
Adapter
Series Receptacle Basic Receptacle* Basic Receptacle*
HSE + + + N/A
Angle Enclosure JE3 JE6
1" Std. Conduit Size 1d" Std. Conduit Size
Series Receptacle Basic Receptacle*
HSH ++
Horizonal Horizontal JB3 N/A N/A
Mount Box 1" Std. Conduit Size
++
Angle Adapter JHA3 (20°)
Receptacle Mounting Options
Progressive Assembly
* Select appropriate receptacle by rating, configuration and voltage on Page
H108.
Ordering: Order individual pairs or use series letters followed by receptacle I.D.
(ref. HSA series number). Example: HSB8414.
(For HSA use receptacle catalog numbers only.)
Heavy Service Ever-Lok®– Receptacle Mounting Options
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H109
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 109
H110 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Industrial and Commercial
H
Russellstoll ®
Heavy Service Ever-Lok®– Dimensions
Panel
Amp Y V U T S R Opening
30 2.750" 2.250" 2.250" 0.213" 3.250" 7.000" 2.250" D
60 3.500" 2.875" 2.875" 0.281" 4.625" 8.875" 2.875" D
100 4" 3.375" 3.375" 0.281" 5.875" 10.500" 3"
Plugs and Connectors
Dimensions for 2, 3 or 4 wire Weathertight Units
Female - Connector
Basic Receptacles
Dimensions for 3 or 4 wire Units
* Length of plug exposed when engaged in receptacle or connector.
Amp A B C* D E F G H
30 2" 3" 5.625" 7" 1" 7.625" 2.750" 1.125"
60 2.625" 3.750" 7.687" 9.750" 1.500" 9.625" 3.500" 1.500"
100 2.625" 3.750" 7.687" 11" 1.50" 10.875" 4" 1.875"
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 110
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H111
Industrial and Commercial
H
Russellstoll ®
Heavy Service Ever-Lok®– Dimensions
Panel
Amp Series Z Y X V U T Q P S R Opening
HSA(20°) 4.500" 3.000" 2.375" 2.687" 3.687" .250" 7.375" 7
HSA (45°) 4.500" 3.000" 2.375" 2.687" 3.687" .250" 7.875" 6.625"
HSR 4.500" 3.000" 2.375" 2.687" 3.687" .250" 6.750"
HSB 3.125" 3.125" 2.250" 2.250" .213" 6.250" 2.250"
HSE 3.50" 4.000" .250" 1.250" 2.375" 5.250" 7.250"
HSH 3.937" 4.500" 2.375" 3.687" 2.687" .250" 7.250" 6.125"
HSA (20°) 5.625" 4.000" 3.000" 3.812" 4.937" .343" 9.250" 8.875"
HSA (45°) 5.625" 4.000" 3.000" 3.812" 4.937" .343" 9.875" 8.250"
HSR 5.625" 4.000" 3.000" 3.812" 4.937" .343" 8.375"
HSB 3.187" 3.625" 2.187" 2.625" .281" 9.250" 2.500"
HSE 4.250" 3.125" 4.500" .281" 1.562" 3.687" 6.750" 9.750"
HSA (20°) 5.500" 5.500" 3.750" 6.750" 4.250" .343" 10.750" 10.500"
HSA (45°) 5.500" 5.500" 3.750" 6.750" 4.250" .343" 11.750" 9.500"
HSR 5.500" 5.500" 3.750" 6.750" 4.250" .373" – 12.250"
HSB 3.187" 3.625" 2.187" 2.625" .281" 9.250" 2.500"
Standard Series HSA Series HSR Series HSB
Series HSE Series HSH
Note: U = horizontal mounting hole centers; V = vertical mounting hole centers
30
60
100
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 111
Industrial and Commercial
H
Russellstoll ®
30 Amp Tapped Hole 60 Amp Tapped Hole 100 Amp Tapped Hole
Cat. No. Size NPT Cat. No. Size NPT Cat. No. Size NPT
JPA31 d"JPA62 f"JPA104 1b"
JPA32 f"JPA63 1" JPA105 1d"
JPA33 1" JPA64 1b"* JPA106 2"
Heavy Service Ever-Lok®– Accessories
Female Interiors: Receptacles & Connectors Male Interiors: Plugs
Poles/Wires 30 Amp 60 Amp 100 Amp 30 Amp 60 Amp 100 Amp
2P, 3P ARU323 ARU623 — APU323 APU623
3P, 4W ARU334 ARU634 ARU134-6 APU334 APU634 APU134-6
Replacement Interiors
For Receptacles, Connectors, Plugs & Male Inlets
Notes:
Interiors – arc-resisting composition with machined, full floating, self-aligning contacts.
Solder lug interior will not interchange with mechanical lug. If you have solder lugs, reorder solder lugs.
Accessories
Adapters are tapped NPT standard pipe thread to
accommodate rigid conduit or standard connectors for
armored and non-metallic cable or flexible conduit.
Plug or Connector Sizes
Notes:
Material – cast aluminum, corrosion-resistant copper-free alloy, electrostatic
epoxy coated. Furnished complete with gasket and screws.
To specify standard plugs or connectors equipped with one of the
above adapters, add the catalog number of the adapter selected to the catalog
number of the plug or connector. Complete list price is the list price of the device
plus list price of the adapter.
Example: Cat. No. 8443 with adapter tapped 1-inch would be Cat. No.
8443/JPA33
JPA 64
Conduit
Adapter
H112 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 112
Industrial and Commercial
H
Russellstoll ®
Hole Diameter
for Cable 30 Amp 60 Amp 100 Amp
.375" JG31
.500" JG32
.563" JG325
.594" JG32B
.625" JG33 JG63
.750" JG34 JG64 JG104
.781" JG341
.875" JG35 JG65 JG105
.937" JG355
1.000" JG38* JG66 JG106
1.125" JG361*
1.188" JG67 JG107
1.313" JG108
1.375" JG69*
1.500" JG610* JG1010
1.687" JG1011
1.813"
1.875" JG1013*
2.000"
2.125"
2.250"
2.500"
Heavy Service Ever-Lok®– Accessories
Cable Bushings
Boxed catalog numbers are standard bushing sizes. To order non-standard bushing, specify as follows:
example 8418/JG65
Notes:
When ordering, select bushing size slightly larger than your cable O.D. for best fit.
Material – Neoprene
Identification
Letter Inside
Hole
Size No. 3 – 6 – 10 and 20
Size No. 3 – 6 – 10 and 20
Standard Cable Bushings: * Oversize Cable Bushings:
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H113
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 113
Control Circuits Connectors – Overview
SK/SKW
Multi-Pin
Control Circuit
to 11P12W
20A
Switches
125 / 250VAC
10, 20 & 30A
Interlocks
thru 4P5W
30 thru 400A
The toughest multi-circuit, screw-
termination circular connector system;
as SK indoor self locking or SKW
outdoor collar locking; load breaking
at 20 amps. Solid brass (silverplated)
contacts ensure long life and interiors
can be rebuilt. All pin-counts are
available from 3P4W thru 11P12W,
gasketed interiors in SKW.
SPST and SPDT Tumbler Switches
are offered in industrial and
hazardous duty styles. Heavy duty
Cu-free aluminum housings (brass
available) around selected common
ratings. Switches carry AC-only
ratings (see Hazardous Duty section
for explosion proof switches).
A broad offering of performance
interlocks in sheet steel, cast
aluminum or brass.
Automotive/Industrial welding units
include 60 & 100A versions, both
Heavy Service Ever-Lok and MaxGard
lines. Switched, fused and circuit
breaker versions are available, as well
as switchgear selections. Custom
enclosures wall-mount or column-
mount in standard 8" I-Beam webs.
Defined
General IndustrialMarine
Lighting Systems
Shore to Ship Power
Welding Stations
Portable Distribution Centers
Shipboard Power Outlets
Telephone Shore-Ship
Construction &
Agriculture
Generator Sets & Systems
Portable Tools & Equipment
Irrigation System Panels
Portable Lighting &
Equipment
Government, Municipal & Utilities
Portable Building Power
Army Corps of Engineers
Utilities Panels
Emergency Power Systems
Sewage Pumping Stations
Lighting & Controls
Industrial & OEM
Factory Power Outlets
HVACR Controls
Machine Tool Controls
Amusement Park Systems
Typical Application Groups
Russellstoll Line Selections for Indoor Applications
Any application where electrical connections need
protection from water and/or dust ingress to the
contacts or the wiring compartment.
Cable or conduit sealing and device locking designs
are critical.
Metal connectors are usually preferred for long
service life.
H114 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 114
Control Circuits Connectors – Type SK & SKW Overview
Features and Benefits
20 Amp, 250 Volts AC or DC, 600 Volts AC Max. Rating
Load-Breaking Multi-Circuit Receptacles, Plugs, Connectors and Inlets
Type SK
Type SK Multi-Circuit Receptacles, Plugs Inlets and
Connectors are designed for indoor or NEMA 1 Automatic
Press, Tool Control and Welder applications requiring rugged,
shock-resistant devices capable of safely interrupting rated
currents under load.
Receptacles and connectors have neoprene gasket mounts
and positive grounding path through separate contact.
Equipment grounding contacts make first and break last.
Wiring space is generous. Listed ratings are for interrupting
currents under load.
The time-tested Ever-Lok automatic locking feature provides
positive connections under the most severe conditions of
shock and vibration. Yet, a twist of the wrist instantly
disengages the plug when required.
Type SKW
Type SKW Multi-Circuit Receptacles, Plugs Inlets and
Connectors are designed for outdoor NEMA 4, rough service
and critical environment Machinery, HVACR systems, Servo
Control and other automatic/controlled functions requiring
rugged, shock-resistant devices capable of safely breaking
rated loads. These watertight & oil-tight devices are
equipment grounded with ground contacts that make first and
break last. Wiring space is generous. Listed ratings are for full
load interrupting currents.
Both series feature simple set-screw wiring termination in a
circular connector with up to 11 pole 12 wire circuit capability.
A wide selection of cable bushings can be specified upon
ordering at no additional charge. Conduit adapters are also
available for shielded or construction usage for both SK and
SKW series.
Note: More than 12 circuits, miniature connectors or rectangular format. Ask about T&B
Pos-E-Kon Line.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H115
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 115
Female Connector*/ Female Cable
Poles/ Receptacle Male Plug Male Receptacle Female Plug Connector Bushing
Wires Style SKR Style SKP Style SKRR Style SKCU Style SKC Hole ID
2P3W SKR3G SKP3G SKRR3G SKCU3G SKC3G e"
3P4W SKR4G SKP4G SKRR4G SKCU4G SKC4G e"
4P5W SKR5G SKP5G SKRR5G SKCU5G SKC5G f"
5P6W SKR6G SKP6G SKRR6G SKCU6G SKC6G f"
6P7W SKR7G SKP7G SKRR7G SKCU7G SKC7G f"
7P8W SKR8G SKP8G SKRR8G SKCU8G SKC8G g"
8P9W SKR9G SKP9G SKRR9G SKCU9G SKC9G g"
9P10W SKR10G SKP10G SKRR10G SKCU10G SKC10G 1"
10P11W SKR11G SKP11G SKRR11G SKCU11G SKC11G 1"
11P12W SKR12XG SKP12XG SKRR12XG SKCU12XG SKC12XG 1"
Indoor, NEMA1, 20 Amp Load Breaking
250 Volts DC, 600 Volts AC (Max Rating)
* Connectors – Both SKCU and SKC connectors will mate with standard service SKP plugs. SKC devices offer external shroud protection for female contacts. Both devices will lock
with plug.
Note: Conduit Fittings: Plugs and connectors can be furnished with adapters to accommodate rigid conduit or standard connectors for armored and non-metallic cable or flexible
conduit. See page H123. Special Construction: Press Control Lockout Dummy, Cat. #SKPD-
Specifications
Receptacle Housing – Furnished with neoprene gasket and 6-32 mounting screws.
Type SKWR – Cast aluminum, corrosion-resistant copper free alloy.
Style SKR - heavy gauge steel, plated
Plug Housing
Type SKP – Steel, zinc plated with heavy cast aluminum alloy cable clamp and cable bushing.
Type SKWP – Cast aluminum, corrosion-resistant, copper-free alloy, epoxy powder coat finish. Furnished with heavy cast cable clamp and cable bushing.
Connector Housing – Cast aluminum , corrosion-resistant, copper-free alloy, epoxy powder coat finish. Furnished with heavy cast cable clamp and cable bushing.
Conduit Boxes – cast boxes for above receptacles are listed on page H120. Type SK receptacles require FD series or DSFD box. Can be furnished with single gang outlet box at
additional cost. When required, add suffix catalog number of box to catalog number of receptacle.
Cable Bushing – oil resistant, neoprene strain relief cable bushing regularly furnished with hole size as listed. Other hole sizes available at no extra cost if specified on order.
See page H123 for additional sizes.
Interiors – contacts are removable and have pressure type terminals for 12 AWG wire maximum conductors.
Insulating Bodies – arc and impact-resisting mold composition.
Contacts – silver plated with fully insulated pressure screw-type terminals.
Repair Kits – Pins/Sleeves Repair – components for rebuild of 2-4 interiors
Male Devices Cat. No. SKX12MS
Female Devices Cat. No. SKX12FA
Control Circuits Connectors – Type SK Ordering Information and Specifications
Standard Service Reverse Service Connector
H116 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 116
Control Circuits Connectors – Type SK Dimensions
Standard Service
Female Receptacle – Style SKR Male Plug – Style SKP
Note: All require FD or DSFD series box mounting.
Reverse Service
Male Receptacle – Style SKRR Female Plug – Style SKCU (Non-shrouded connection)
Connector
Female Connector – Style SKC (shrouded style)
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H117
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 117
Female Female Male Cable
Poles/ Receptacle Male Plug Connector Motor Plug Bushing
Wires Style SKWR Style SKWP Style SKWC Style SKWM Hole ID
2P3W SKWR3G SKWP3G SKWC3G SKWM3G e"
3P4W SKWR4G SKWP4G SKWC4G SKWM4G e"
4P5W SKWR5G SKWP5G SKWC5G SKWM5G f"
5P6W SKWR6G SKWP6G SKWC6G SKWM6G f"
6P7W SKWR7G SKWP7G SKWC7G SKWM7G f"
7P8W SKWR8G SKWP8G SKWC8G SKWM8G g"
8P9W SKWR9G SKWP9G SKWC9G SKWM9G g"
9P10W SKWR10G SKWP10G SKWC10G SKWM10G 1"
10P11W SKWR11G SKWP11G SKWC11G SKWM11G 1"
11P12W SKWR12XG SKWP12XG SKWC12XG SKWM12XG 1a"
Note:
* SKWM Male Inlet accommodates SKWC Connector (Female) Plugs and connectors can be furnished with adapters to accommodate rigid conduit or standard
connectors for armored
and non-metallic cable or flexible conduit. See page H123.
Control Circuits Connectors – Type SKW Ordering Information and Specifications
Ordering Information
Outdoor, NEMA 4 (with screw cap)
20 Amp Load Breaking
600 Volts AC Max
250 Volts DC
Specifications
Receptacle Housing – Type SKWR – Cast aluminum, corrosion-resistant copper free alloy. Furnished with neoprene gasket and stainless steel 6-32 mounting screws.
Plug & Connector Housing – Heavy cast aluminum, corrosion-resistant copper-free alloy, epoxy powder coat finish. Furnished with heavy cast cable clamp and cable bushing.
Conduit Boxes – cast boxes for above receptacles are on page H120. Can be furnished with single gang outlet box at additional cost. When so required, suffix catalog number of
box to catalog number of receptacle.
Cable Bushing – oil resistant, neoprene strain relief cable bushing regularly furnished with hole size as listed. Other hole sizes available at no extra cost if specified on order.
See page H123 for additional sizes.
Protective Caps – Waterproof caps complete with mounting cable.
Male Devices Cat. No. F26874C (Cup Cap)
Female Devices Cat. No. F04077 (Screw Cap)
Repair Kits – Pins/Sleeves Repair – components for rebuild of 2-4 interiors
Male Devices Cat. No. SKX12MW
Female Devices Cat. No. SKX12FA
H118 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 118
Control Circuits Connectors – Type SKW Dimensions
Receptacle
Style SKWR Style SKWP
Note: All require FD or DSFD series box mounting.
Connector
Style SKWC Style SKWM
Plug
Motor Plug
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H119
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 119
No. of Gangs Type Cast Aluminum Cast Brass *Overall Dimensions
FS 3701A 3721 4.12" x 2.62" x 2.31"
Single FD 3711A 3731 4.12" x 2.62" x 2.94"
DSFD 3781A 3782 4.12" x 3.62" x 4.12"
Two FS 3702A 3722 4.12" x 5.5" x 2.25"
FD 3712A 3732 4.12" x 5.62" x 2.87"
Control Circuits Connectors – Accessories
Standard Outlets
Cat. No. Top Bottom
FSWS-62 f" NA
FDWS-62 f" NA
FDWS-622 f" f"
FDWS-63 1" NA
FDWS-633 1" 1"
Mounting options for Midget & Standard Everlok
Type FS (shallow) & Type FD (deep)
Aluminum boxes have 6-32 cover mounting holes tapped to accommodate all FS and FD cover assemblies.
Brass boxes have 10-24 cover mounting holes tapped to accommodate all FS and FD cover assemblies.
Single Gang Two Gang DSFD
Notes:
When type FD devices are to be mounted in boxes, type FD boxes should be used. FS boxes will not accommodate FD devices.
Mounting – all the above boxes are for surface mounting. For flush mounting see page H121.
Boxes – Cast brass, natural finish. Cast aluminum, corrosion resistant
copper-free alloy, epoxy powder coat finish.
* Dimensions are overall exclusive of conduit pads and mounting lugs.
Outlets – unless otherwise specified, furnished with one .75" outlet per gang, top or bottom. Additional outlets charged extra – see price list. Specify size and location.
Maximum Conduit – FS and FD: 1", one per gang top and bottom and one each side.
DSFD: one 1.5" or two .5" top and bottom.
Cast iron available on special order – consult factory.
Type FSWS and FDWS (with mounting shelf for box-mounted devices)
Aluminum Die-Cast Boxes with cover mounting holes tapped for 6-32 screws to accommodate all FS and FD cover
assemblies.
Notes:
Boxes – Aluminum die-cast, corrosion-resistant, copper-free alloy,
epoxy powder coat finish.
Outlets – standard as listed.
Mounting – all of the above boxes are for surface mounting.
H120 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 120
Covers Standard FS/FD box openings
Cast Aluminum 3677A
Cast Brass 3687
Control Circuits Connectors – Accessories
No. of Gangs Cast Aluminum Cast Brass Overall Dimensions
13671A 3681 5" x 3.5"
23672A 3682 5" x 6.5"
Adapter Flush Frames*
Blank Cover* Flush Wall Mounting Extension*
Cast Aluminum 3679A
Cast Brass 3679B
45° Angle Adapter*
Mounts to any FS/FD box.
Cast Aluminum 3678A
Cast Brass 3678B
* Furnished complete with gasket and screws.
Materials: Cast aluminum, corrosion-resistant, copper-free alloy, epoxy
powder coat finish. Cast brass, natural finish.
Adapter Sub-Plate
The addition of this adapter sub-plate will permit the use
of Ever-Lok conduit box-type receptacles in switch
boxes or outlet boxes with raised covers, as listed. Used
on standard (deep) stamped metal conduit boxes.
Adapts two hole to four hole patterns.
SKWM Mount Adapter Plate
Used to mount SKWM to FS/FD standard series boxes.
Aluminum SKWMFS
Cast Aluminum 8091A
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H121
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 121
Control Circuits Connectors – Accessories
Multiple Gang Dimensions
AB
FS FD FS FD
2-Gang 6.50" 6.50" 5.50" 5.62"
Type FS & FD
Single Gang Multiple Gang
4.12"
.31"
4.12"
2"
2.62"
3.62"
3.18"
MTG
.31"
2 MTG. Holes
4.37"
MTG
DSFD
Type FSWS & FDWS Blank Cover
Flush Mounting Extension 45° Angle Adapter
FS/FD
FS FD
H122 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 122
Adapter tapped with NPT thread to accommodate
armored and non-metallic cable or flexible conduit.
Hole Diameter Size 3
for Cable 20 Amp
.375" JG31
.500" JG32
.563" JG325
.625" JG33
.750" JG34
.875" JG35
1.000" JG36*
1.125" JG361**
Control Circuits Connectors – Accessories
Combination Gland Nut and Cable Clamp Adapters for Conduit
Cable Bushings
Size 3
Cable Bushing
Provides extra clamping protection in hard service
applications. Relieves terminals and rubber gland of all
cable strain.
Notes:
Material – cast aluminum, corrosion-resistant, copper-free alloy, cast brass,
epoxy powder coat finish or cast brass, natural finish.
Material – oil resistant neoprene.
Size 3 Cable Bushing:
*Style for Maximum Cable only.
**Special minimum wall style.
Notes:
When standard plugs or connectors are required to be furnished with one or more of the above accessories, add the suffix and catalog number of the accessory selected by a “/” to the
catalog number of the plug or connector. Complete list price is the total of the list price of the device plus the list price of the accessory.
EXAMPLE – Catalog No. SKP9G with with 1" bushing would be Catalog No. “SKP9G/JG36.”
Plug or Cast Cast Max
Connector Aluminum Brass Cable
Size Cat. No. Cat. No. Dia.
20 Amp
&3906 3906B 1a"
SKW
Plug or Cast Cast Tapped
Connector Aluminum Brass Hole
Size Cat. No. Cat. No. NPSM
20 Amp FSA21 FSA21B d"
&FSA22 FSA22B f"
All SKW FSA23 FSA23B 1"
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H123
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H07 ELOK 3/5 3/14/03 7:03 PM Page 123
125/250 VAC Rating Cast Cast
Switch Hp Amps Aluminum Brass
1.5/2.0 15 3705S7 3725S7
Single Pole / Single Throw 1.0/2.0 20 3705S27 3725S27
2.0/2.0 30 3705S37 3725S37
1.5/2.0 15 3706D7 3726D7
Double Pole / Single Throw 1.0/2.0 20 3706D27 3726D27
2.0/2.0* 30 3706D37 3726D37
Watertight
Heavy Duty Tumbler Switches
General use heavy duty switches are applied to control a variety of lighting, power and machinery branch circuit loads. They
can be used with any Russellstoll industrial receptacle for maximum control system flexibility.
Ordering Information
1-2 HP Rated
Notes:
Switches rated 15 or 20 Amp. 277 volts, A.C. and with other than listed ratings can be furnished. Prices and information on application. AC only.
* Also rated 1 Hp, 460VAC or 2Hp to 600VAC.
Boxes Available in cast aluminum, cat. no. 3701A and cast brass cat. no. 3721.
Specifications
Enclosures – Corrosion resisting baked enamel finish.
Cast brass, natural finish.
Gang Types – Can be furnished in 2 gang aluminum or
tandem units and in combination with other Russellstoll
FS and FD devices. Contact Technical Services.
Outlets – Unless otherwise specified, furnished with one
f" outlet per gang, top or bottom. Additional or larger
outlets charged extra – see price list. Maximum conduit
1": single gang – top and bottom only, multiple gang –
one per gang top and bottom and one each side.
Specify size and location.
Flush Mounting – Adapters for flush mounting are listed
on page H121.
Dimensions
4.62"
5.38"
2.56"
4.75"
3.00"
3.75"
6.81"
4.75"
6.12"
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H125
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 125
Industrial Interlocked Receptacles are available in 30 thru 400 Amp.
Switched receptacles have mechanical linkages for added safety. Safety
features include:
Plugs cannot be inserted unless power is safely turned off.
Plugs cannot be removed until power is turned off.
Specialty designs may also automatically disengage power if plug is
removed while power is on, either mechanically or electrically.
Applications
Applications where these units are most commonly used are:
Welding stations in automotive and heavy industry.
Temporary and portable power distribution for construction.
Marine shore to ship power.
Industrial machinery installation.
Portable power distribution, vehicle and gen set power for aerospace.
Custom systems in all industries.
Industrial Interlocked Receptacles – Overview
Sample Installation: Fixed Power Source (Wall) To Remote/Portable Location
1. Receptacle (wall mtg.) (female) 4. Female Connector
2. Receptacle (panel mtg.) (female) 5. Male Inlet w/Angle Adapter
3. Plug (attachment) 6. Male Inlet w/Straight Adapter
Other Installations: Generator Power Sources, Custom Control Circuits, Multiple Voltage Service –
Contact Technical Services.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H127
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 127
Industrial Interlocked Receptacles – Overview
The Most In Mounting Options
Industrial Wall Mount Interlocks
Indoor service NEMA 3R.
Fused protection.
30-100A Models, 600V.
Heavy Service EverLok®or MaxGard®interfaces.
Automotive / Heavy Industrial I-Beam Web Mount
Indoor service NEMA 12/3R.
Fused or circuit breaker protection.
30-100A Models, 600V.
Stepdown transformer-disconnect designs with convenience outlets.
Cast aluminum & sheet steel housing versions.
Mounts inside web of standard 8" I-beam column.
Interfaces with Heavy Service Ever-Lok, MaxGard, Standard Ever-Lok and FS/ FD.
Marine / Heavy Industrial & Custom
Outdoor service NEMA – 3R to 4X.
Switched or circuit breaker protection.
30-400A Models, 600V.
Cast aluminum or cast brass.
Mounting to customer specifications.
Interfaces with MaxGard, FS/FD and more.
H128 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 128
Fused Disconnect** Std.
Interlocked Receptacle Mating Bushing
Poles NEMA 12/3R MaxGard Plug ID
Wires Voltage Cat. No. Cat. No.
2P3W 125 DFRF31070 DS3107MP000 g"
30 2P3W 250 DFRF32070 DS3207MP000 g"
Amp 3P4W 3Ø250 DFRF33070 DS3307MP000 1"
3P4W 3Ø480 DFRF34040 DS3404MP000 1"
4P5W 277/480 DFRF35040 DS3504MP000 1i"
2P3W 250 DFRF62070 DS6207MP000 1i"
60 3P4W 125/250 DFRF63070 DS6307MP000 1j"
Amp 3P4W 3Ø480 DFRF64040 DS6404MP000 1j"
4P5W 277/480 DFRF65040 DS6504MP000 1d"
2P3W 250 DFRF12070 DS1207MP000 1W"
100 3P4W 125/250 DFRF13070 DS1307MP000 1m"
Amp 3P4W 3Ø480 DFRF14040 DS1404MP000 1m"
4P5W 277/480 DFRF15040 DS1504MP000 2"
Fasteners Screws
2 Places
Holes for Padlock
2 Places
CD
B
A
F
E
7.50
2.18
ON
OFF
Industrial Interlocked Receptacles – Overview
MaxGard’s Fused-Disconnect Interlocked Receptacle with safety switch, meets UL, NEC
and major automotive specifications. This unit is the maximum in:
Safety
Door safety switch, with three external lockout points.
Safety fuse pulls for standard class R fuses.
Backup door safety latch.
Durability
Heavy .060 steel galvaneel with baked enamel, NEMA 3R/12 construction.
Clear shield for test probes.
Performance
Standard 600V cartridge fuse clips and spacing.
Fully interlocked MaxGard receptacle.
Angled front receptacle for easier access.
Conduit Hubs
Std. NPT
Amp thread outlet Max
30 1d"2d"
60 2" 2d"
100 2" 2d"
Notes:
** Non-fused version available: Specify
DNRF ________ . (Non-U/L)
Standard polarizations shown. Boldface figures
are for voltage assignment; for different ratings
see page H20.
Control Contacts (position 9) use “K” example: DFRF1207K
Always use liquid-tight fittings to limit condensation entry.
Amp A B C D E F
30 9d"f" 25f" 25" 22f" 30"
60 9d"f" 25f" 25" 22f" 30"
100 9d"f" 25f" 25" 22f" 30"
E5239
Specifications on page H14.
MaxGard Fused-Disconnect** Interlocked Receptacle with Disconnect Switch
Available in 30, 60 and 100 amp sizes, all polarizations.
Ordering Information
Maximum 600 VAC
or 250 VDC
Dimensions
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H129
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 129
Industrial Interlocked Receptacles – Fused-Disconnect Interlocked Receptacle/Safety Switch
Heavy Service Ever-Lok 60 Amps
19.62 MTG
26.45
6.50 MTG
Ø.56
3 PLS
6.69
7.24
30°
6.66
5.25
5.55
9.37
Standard fused/non-fused disconnect interlocked receptacle
and safety switch is specified by major automotive
manufacturers for welding disconnects and other
applications. The Heavy Service Ever-Lok system features
‘one-handed’ insertion, locking and removal with your choice
of switchgear!
Benefits
Specified switchgear: GE or Square D.
Door safety switch with external lockout access.
Backup door safety latch.
Push-in plug locking: no screw collars needed.
Full interlocked outlet protection and functions.
Angled front receptacle in compact one handed interlock.
Options (Custom Capabilities)
Other Russellstoll product interfaces.
30, 60, 100 or 200 amp installations.
Specialty enclosures for your application.
Circuit breaker interlocked mechanisms.
* See pages H107-H113 for full Heavy Service Ever-Lok line
Features
Heavy steel galvaneel with baked enamel finish.
NEMA 3R/12 construction.
Standard 600V class, Type R fuses.
Listed components.
GE Switchgear
Cat. No. Mating Plug
TH3362JRS 8418 or F27194†
(Mating Plugs sold separately)
*other styles available
† F27194 Automotive 480VAC Label
Ordering Information
Square D (mechanism)
Cat. No. Mating Plug
ESDFH8414F00 8418 or F27194†
(Mating Plugs sold separately)
*other styles available
† F27194 Automotive 480VAC Label
Also available: Many options for
mounting, configuration or interfaces.
H130 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 130
Benefits
Transformer Disconnects offer a combination of voltage outlets from a single facility 480V 3Ø
service drop. Standard configurations include a fused, interlocked 480VAC, 60A 3Ø
receptacle outlet and separately protected 120/240 VAC, 15-20A convenience outlets.
Custom configurations are available to meet your application requirements.
Quickest way to expand or build a single voltage factory or facility, with voltage
combinations available at every power drop.
Safest way to operate: with fuses and breaker protection for each receptacle. 60A plug
cannot be inserted or removed unless power is “off”.
Most cost effective way of providing power and convenience outlets in one location; wall
mount or column mount in standard 8" I-beam pillars.
Specifications
Electrical & Safety Features:
Fused 480VAC 60A 3P4W Receptacle + Fused Dual 125 VAC 20A 2P3W Outlets 20A
Combination breaker/GFCI convenience outlets on door.
Heavy Duty (8 hour rated) 2KVA 480VAC-120VAC (fused primary) transformer 4KVA
option available.
Mechanical and Safety Features:
Three Point, Two-way Interlock Function:
– Blade type disconnect handle interlocked with door handle.
– Main disconnect uses steel rod arm interlock to 480VAC outlet.
High strength 3-point door hinge design.
Standard 8" I-Beam web vertical mounting or conventional wall mount.
Easy access angled front 480VAC receptacle position.
Heavy duty 14 gauge steel NEMA 3R/12 welded enclosure with gasketed door
Electrostatic epoxy powder coat gray finish.
Dual lockout locations on main switch handle and door handle.
Optional Construction Features:
Stepdown transformer 2KVA/4KVA and secondary.
30/60A outlet (Heavy Service Ever-Lok, Angle Type or 30A MaxGard).
Convenience outlet styles, types and protection.
Ordering Information
(many other configurations available)
480VAC 60A Mating 120VAC 20A Mating
Cat. No. Receptacle Plug Receptacle Plug
ERSFH8414FBB 8414Spl. 8418 or F27194† 8003N (x2) 8593CTN*
ERSFH8414FDC 8414Spl. 8418 or F27194† 8003U-1 (x2) 8013U-1*
(Mating Plugs sold separately) *Other styles available
†F27194 Automotive 480VAC Label 100A also available - consult factory
ERSFH8414FBB
ERSFH8414FDC*
*A number of convenience outlet
types, including NEMA bladed styles
can be supplied.
Industrial Interlocked Receptacles – Combination Interlocked Transformer Disconnect
Automotive/Heavy Industrial I-Beam Web Mount
Combination Interlocked Transformer Disconnect
60 Amp, 480 VAC plus 120 or 240 VAC convenience outlets to spec.
3P4W (100A also available)
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H131
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 131
6.75
4.00
MTG
Mains Disconnect
Door Handle
Convenience Outlets
to spec
Breaker/GFCI
Protection to spec
60A Outlet
11.75
7.00
36.37
MTG
37.37
35.37
ø .41
4 PLS
RECEPTACLE
480 VOLT
CIRCUIT BREAKER GFCI
TWO RECEPTACLES
120 VOLT TRANSFORMER
FUSE HOLDER
FUSED
SWITCH
Wiring Diagram
Industrial Interlocked Receptacles
Dimensions
H132 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 132
Interlock Mating
Cat. No. Type Plug
CFCSRA13-60 Switched Only 8418 or F27194†
F32753‡ Circuit-Breaker 8418 or F27194†
(Mating Plugs sold separately)
† Automotive 480VAC
‡70A Trip version F26313 and other variations also available.
ON
OFF 12.25"
14.88"
6.12"
20°
480V
Receptacle
7.12"
Approx.
4.00"
MTG
10.00"
MTG
Ø .28
4 Pls
MTG
10.00"
Ø 3.62"
Industrial Interlocked Receptacles –
Ever-Lok®Mechanically Interlocked Receptacle and Switch
Automotive/Heavy Industrial I-Beam Web Mount
Heavy Service Ever-Lok®Mechanically Interlocked Receptacles and Switch
60 Amp, 480 VAC/250VDC, 3P4W
Circuit Breaker Interlocked Receptacle Option
Features and Benefits
Note: CFCSRA13-60
replaces previous Cat.
#FCSRA13-60.
Mechanically Interlocked Switch
Dimensions
Mating Plug
114" NPT Top Entry Std. / other sizes available. 60A, 3P4W, 8418 or F27194
* 17" dim. for F32753 unit.
Ordering Information
Mechanically interlocked between
the receptacle and the switch.
Designed so that when the plug is
fully inserted the switch interlock is
automatically released, permitting the
switch to be turned on. The plug
cannot be removed from the
receptacle until the switch is
manually turned off.
Switch: 60 Amp, 480VAC, 3 pole,
quick “make” and quick “break”.
Housings: heavy cast aluminum
corrosion-resistant copper-free
alloy with gray electrostatic epoxy
powder coat finish. Furnished with
oil-resistant gaskets.
Handle lock-out feature.
Circuit-breaker interlocked version
available in standard and high AIC
models.
One-handed insertion or removal:
unique auto-locking collar
engages upon insertion, a"
counter-clockwise turn
disengages for removal.
Simple and rugged full interlock
safety. Plug cannot be inserted or
withdrawn while power is on.
Fits in standard 8" I-beam web or
wall mounting.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H133
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 133
Mating
Cat. No. Plug
F34331 F34332
(Mating Plugs sold separately)
OFF ON
0.34"
4 PLS
5.06"
MTG
5.88"
MTG
4.62"
5.62" Ø 2.25"
Industrial Interlocked Receptacles – Interlocked Switch (30A, 480VAC)
Automotive/Heavy Industrial I-Beam Web Mount
Interlocked Switch (FS/FD Interface)
30 Amp, 480 VAC
3P4W (other polarizations available)
Features and Benefits
Interlocked Switch
Dimensions
Mating Plug
F34331
Ordering Information
The FS/FD Interlocked Switch is made
of heavy duty cast aluminum. The
mechanical interlock functions when
the plug is fully engaged allowing the
switch to be operated. Basic interlock
design has many variations including
screw cover, brass and circuit breaker
versions.
• Male plug cannot be plugged or
unplugged under load.
• Dead-front female receptacle for
safety.
• Weathertight receptacle made of
cast aluminum, corrosion resistant
copper-free alloy, gray electrostatic
epoxy powder coat finish.
• Compact size for limited space
applications.
• Available with UL style steel back
boxes to user specifications.
H134 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 134
Amp A B C D E F G
30 c" 8f" 6d" 1d" 16b" 15a" 3a"
60 c" 8f" 6d" 1d" 16b" 15a" 3a"
100 c" 8f" 6d" 1d" 16b" 15a" 3a"
200 l" 12b"9" 2d" 26b" 24f" 5"
400 l" 15d" 12" 3" 30d" 29"6"
Mechanically Std.
Interlocked Receptacle Mating Bushing
Poles NEMA 4x MaxGard Plug ID
Wires Voltage Cat. No. Cat. No.
2P3W 125 DBRF310703000 DS3107MP000 g"
30 2P3W 250 DBRF320703000 DS3207MP000 g"
Amp 3P4W 3Ø250 DBRF330703000 DS3307MP000 1"
3P4W 3Ø480 DBRF340403000 DS3404MP000 1"
4P5W 277/480 DBRF350403000 DS3504MP000 1i"
2P3W 250 DBRF620706000 DS6207MP000 1i"
60 3P4W 125/250 DBRF630706000 DS6307MP000 1j"
Amp 3P4W 3Ø480 DBRF640406000 DS6404MP000 1j"
4P5W 277/480 DBRF650406000 DS6504MP000 1d"
2P3W 250 DBRF120710000 DS1207MP000 1W"
100 3P4W 125/250 DBRF130710000 DS1307MP000 1m"
Amp 3P4W 3Ø480 DBRF140410000 DS1404MP000 1m"
4P5W 277/480 DBRF150410000 DS1504MP000 2"
3P4W 277/480 DBRF230720000 DS2307MP000 1b"
200 3P4W 3Ø480 DBRF240420000 DS2404MP000 2b"
Amp 4P5W 277/480 DBRF250420000 DS2504MP000 2d"
400 3P4W 277/480 DBRF430740000 DS4307MP000 3"
Amp 3P4W 3Ø480 DBRF440440000 DS4404MP000 3"
4P5W 277/480 DBRF450440000 DS4504MP000 3b"
Conduit Hubs: ( at B or E)
Boldface figures are for voltage assignment; for
different ratings see page H20.
B-Std
E
Dimensions
Industrial Interlocked Receptacles –
Heavy Duty Industrial/Marine Interlocked Receptacle (MaxGard)®
Available in 30, 60, 100, 200 and 400 amp sizes, all polarizations.
MaxGard®NEMA 4x interlocks are ideal for
demanding non-hazardous areas where
dust, dirt, moisture and corrosion might be
a problem-such as shipyards, food
processing facilities, manufacturing
operations or similar areas.
Safety
• Gated dead-front waterproof receptacle.
• Standard, high AIC or NA/switch circuit
breaker.
• Protective screw cap for watertight
protection.
Durability
• Thick wall cast copper-free aluminum
housing with epoxy powder
coat finish.
• Heavy duty sliding bar interlock
mechanism.
Performance
• Heavy on/off handle adds mechanical to
electrical interlock function.
• Standard conduit openings through top or
side.
Control Contacts (position 12)
use “K” example: DBRF6104060K0
Shunt Trip Breaker (position 13)
add “Z” to above: DBRF6104060KZ
Breaker Trip Ratings (positions 9,
10, 11) 30 amp use 030; 50 amp use 050;
60 amp use 060
Non-Auto Sw. NA0 (repl.” DBRF” with
“DSRF”)
For additional full line and polarization
options, see MaxGard section
pages H9-H29.
Std. NPT
Amp thread outlet Max
30 1d" 2d"
60 1d"2d"
100 2" 2d"
Ordering Information
Maximum 600 VAC/250 VDC
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H135
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 135
20A 480V
20A 480V
60A 480V
60A 480V
20A 120V
20A 120V
Power '20'
Service Center
Powertran
Transformer
Unit
Power '60'
Service Center
Power '20'
Service Center
Main Feed
Female
Plugs
60A
480V
60A
480V
60A
120/208V
60A
120/208V
200A 480V 3ø
Industrial Interlocked Receptacles – Portable Power Distribution Centers (Custom)
20-1200 AMP, 120-600VAC
Benefits: Power Convenience and Control
• Customer-specified custom power distribution.
• Many Russellstoll interface combinations.
• Designed-in safety features.
• Indoor and outdoor (to NEMA 4) construction.
• Built in accordance with applicable UL, CSA and NEC standards.
Options
• Amperage and voltages, inputs and outputs.
• Receptacles and/or interlocks used.
• Supply type and protection.
• Distribution or step-down transformers.
• Indoor/outdoor construction, materials & finishes.
• Auxiliary controls and functions.
Applications
• Portable welding power distribution.
• Shore power distribution.
• Combination voltage systems.
• Power and convenience combined.
Typical Schematic Diagram
H136 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 136
Industrial Interlocked Receptacles – Portable Power Distribution Centers (Custom)
Heavy Duty Industrial/Marine
Typical Portable Power Distribution Projects
40.00" 31.00"
28.00"
36.00"
45 KVA
Transformer
le Power Inlet
20.50"
18.75"
1.5
2.00"
25"
16.25"
"
6.00"
1.50" 1.00"Dia.
Hole
18.38"
6.38"
120
208
38.00"
27.00"
3.00"
24.00"
Eye Bolt
2" ID X 4" OD
6.00"
15.00"
6.00"
a. Hole
aker
tacle
embly
Powertran Case
Power 20 Case
Power 60 Case
Input Range: 60 Amps, Reverse Service,
Normally 3P4W, 480VAC, Protect
by 3-Pole Switch.
Transformer: Normally 45KVA, 480 VAC primary,
12/208 VAC, secondary, 3 phase.
Output Range: Three Gang, 30 Amps, Normally
4P5W, 120/208 VAC
interlocked with circuit breaker.
Input Range: 60 Amps, 3P4W, 480VAC or 60
Amps, 4P5W, 120/208VAC.
Output Range: Up to eight gang, 20 Amps, 3P4W,
480VAC or 20 Amps, 2P3W,
120/208VAC Interlocked with
circuit breakers or fused switches.
Input Range: 200 Amps, Reverse Service,
Normally 3P4W, 480VAC Input may
be protected by circuit breaker.
Output Range: Up to eight gang, 30, 60, or 100
Amps, Normally 3P4W, 480VAC,
interlocked with circuit breaker or
switch.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H137
Control Circuit and Industrial/Interlock
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 137
Hazardous Materials
Environment U.S. NEC Stds Euro IEC Stds.
Gas or Vapor Div. 1, Cass I Zone 0 & 1
Div. 2, Class I Zone 2
Dust Div. 1, Class II Zone 10
Div. 2, Class II Zone 11
Fibers/Flyings Div. 1, Class III Zone 10
Div. 2, Class III Zone 11
NEC Art. 500 NEC Art. 505
Group Applications Class I: Groups Zones 0, 1 & 2
A: Acetylene IIC
Div. 1 & 2, Class I B: Hydrogen
C: Ethylene IIB
D: Propane IIA
The above charts are presented for quick reference only and should only be used in conjunction with noted Articles. Further
definition of harmonized standards will be supported by Russellstoll through appropriate specification efforts whenever
practical.
Hazardous Duty Plugs, Receptacles and Interlocks
Russellstoll Hazardous Duty Plugs,
Receptacles and Interlocks are designed
to support a variety of installation needs
throughout 20, 30, 60 and 100A ranges;
where Division 1, Class 1 NEC guidelines
require the utmost in safety.
Unique among others, the Russellstoll
MaxGard also offers true O-ring sealed
waterproof design protection in addition to
standard threaded flame-path construction
employed elsewhere. In rough service,
washdown and outdoor applications,
MaxGard performance goes beyond
normal XP ratings.
With coming increases in harmonized
designations for classifications between
NFPA/NEC and IEC (International)
hazardous area standards, a quick
reference classification chart is provided
below. In all cases, the customer must
determine and approve proper area
classification standards and degree of
harmonized standards acceptance.
Hazardous Duty Applications
H138 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Hazardous Location
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 138
5.75"
B
5.50"
7"
C
A
D
4.75" 3.06"
6.25" Max
2.81" 4.37"
Interlocked Switch and Receptacles
Explosion-Proof: Class I, Groups C and D
Dust Ignition-Proof: Class II, Groups G
These receptacles are for use in general Div. 1 classified
industrial installations such as chemical plants, oil refineries,
bulk stations, distilleries, solvent areas, mills, etc. A higher
degree of safety is afforded by interlocking the plug with the
switch, making it impossible to insert or withdraw plug
under load.
When the polarized plug is inserted into the receptacle and
the plug shell is turned clockwise, it turns the switch to the
“on” position and vice-versa.
Cable Std.
Bushing
Description Flap Cover Screw Cover Plug Hole Dia.
2P 3W 4240FC/ 4240SC 4241 e"
1 H.P. 220/575VAC F16081A
3P 4W 4242FC 4242SC 4243 f"
2 H.P. 110/575 VAC
Specifications
Receptacle Housings – cast aluminum; electrostatic
epoxy powder coated finish.
Plugs – steel, cadmium plated. Furnished with
aluminum alloy cable clamp and neoprene cable
bushing.
Outlets – standard f" top, additional or larger outlets
available. Maximum 1-inch four way. See diagram, use
symbols when ordering.
Cable Bushing – oil resistant, neoprene strain relief
cable bushing regularly furnished with hole I.D. size as
listed. Other hole sizes available consult Technical
Services for catalog number.
Two Gang style – Consult Technical Services.
Approvals: E10919
Dimensions
For 2 gang unit, width 9c"
Mounting Lugs – C. TO C. 10d" W X 5 d" H
Ordering Information
20 Amp, 575VAC
30 Amp, 250VAC
Hazardous Duty Plugs, Receptacles and Interlocks
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H139
Hazardous Location
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 139
Heavy duty XP cast aluminum
housing, electrostatic epoxy
coat finish.
Standard, high AIC and NA
(switched only) breakers available.
Threaded access (cover not
shown) with “O” ring for XP and
waterproof integrity.
Gated
dead-front
safety.
Drain Plug.
Factory sealed receptacle interior. Accepts
standard XP rated MaxGard plugs.
UL and CSA listed for hazardous locations.
Class I, Division 1, Groups B, C and D
Class II, Division 1, Groups F and G
UL File E10919
NEMA 7, 8, 9
CSA
D.O.T. shipboard used above deck “green water”
NEMA 4X
USCG approved.
MaxGard DBRE and DSRE series interlocks
are the only devices certified both explosion
proof and waterproof, along with optional
control contacts, fully UL listed.
Explosion-Proof Waterproof Non-Interlocked Receptacle
Available in 30A 480VAC max., all polarizations.
Heavy duty XP cast aluminum
housing, electrostatic epoxy
coat finish.
• Factory Sealed Interior
(no filled conduits).
• Easy low cost installation.
Threaded access with (cover
not shown) “O” ring for XP and
waterproof integrity.
Gated dead-front for safety.
All standard polarizations
available to 480VAC.
Factory sealed receptacle
interior. Accepts standard XP
rated MaxGard plugs.
Explosion-Proof Waterproof Circuit Breaker Interlocked Receptacle
Available in 30, 60 and 100 AMP sizes, all polarizations. Division 1, Class I & II
Hazardous Duty Plugs, Receptacles and Interlocks
H140 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
UL and CSA listed for hazardous locations.
Class I, Division 1, C and D
Class II, Division 1, Groups F and G
UL File E10919
NEMA 7, 8, 9
CSA
D.O.T. shipboard used above deck “green water”
NEMA 4X
USCG approved.
Hazardous Location
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 140
Poles Voltage Std. Bushing
Wires (VAC) Cat. No. Cat. No. Cat. No. I.D.*
30 Amp
2P3W 125 DBRE310703000 DSE3107FR0 DS3107MP000 g"
2P3W 250 DBRE320703000 DSE3207FR0 DS3207MP000 g"
3P4W 3Ø250 DBRE330703000 DSE3307FR0 DS3307MP000 1"
3P4W 3Ø480 DBRE340403000 DSE3404FR0 DS3404MP000 1"
4P5W 277/480 DBRE350403000 DSE3504FR0 DS3504MP000 1i"
60 Amp
2P3W 250 DBRE620706000 — DS6207MP000 1i"
3P4W 3Ø250 DBRE630706000 — DS6307MP000 1j"
3P4W 3Ø480 DBRE640406000 — DS6404MP000 1j"
4P5W 277/480 DBRE650406000 — DS6504MP000 1d"
100 Amp
2P3W 250 DBRE120710000 — DS1207MP000 1W"
3P4W 3Ø250 DBRE130710000 — DS1307MP000 1m"
3P4W 3Ø480 DBRE140410000 — DS1404MP000 1m"
4P5W 277/480 DBRE150410000 — DS1504MP000 2"
Hazardous Duty Plugs, Receptacles and Interlocks
Maximum
600 VAC or
250 VDC
* Non-fused version available. Replace DFRF with DNRF.
Boldface figures are for voltage assignment; for different ratings see following pages.
* Notes to Catalog Numbers: Suffixes
For specification information and additional bushing sizes see MaxGard section, pages H9-H29.
Explosion-Proof
Interlocked Receptacle Explosion Proof
With Circuit Breaker Receptacle Male Plug
Class I, Class II
*
Dimensions
Explosion-Proof Receptacle
Amp A B C D E
30 8f" 7d" d" 14f" 20"
60 8f" 7d" d" 14f" 20"
100 8f" 7d" d" 14f" 20"
Control Contacts Breaker Trip Ratings
(position 12) (positions 9, 10, 11)
use “K” example: 30 amp use 030
DBRF6104060K0 50 amp 050
60 amp 060
Shunt Trip Breaker Non-Auto Sw. NA0
(position 13) (repl. “DBRE” with
add “Z” to above: “DSRE”)
DBRF6104060KZ
Explosion-Proof Interlocked Receptacle
Ordering Information
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H141
Hazardous Location
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 141
Surface Mount** Cable
Ratings Poles/Wires Straight Angled Flush Mount Bushing Hole Dia.
Type EFS
20 Amp 2P, 3W 4462 4464FC 4445 4803 4466 l"
125VAC or 250VAC 3P, 4W 4463 4465FC 4446 4804 4467 x"
Type DA
30 Amp+ 2P, 3W RA4233BC 4233BC __ __ 4237BC e"
250VAC or 480VAC 3P, 4W RA4234BC 4234BC __ __ 4238BC f"
60 Amp* 2P, 3W RA4263BC 4263BC __ __ 4267BC 1b"
480VAC 3P, 4W RA4264BC 4264BC __ __ 4268BC 1b"
Notes:
**Also available for use at 30 Amp, 480VAC
**Can be furnished with flap or screw cap covers. When so required, add suffix “FC” for flap or suffix “SC” for screw cap to above catalog number. Price on application.
Furnished with plaster gage plate. Requires wall depth of 4-inches minimum.
^ Portable-service receptacles (connectors) Not UL listed.
+ 30 Amp Iron Bodied Plug Family for replacement use only. Not UL listed. (60 Amp carries full listing)
Receptacles Connector^ Plug
Hazardous Duty Plugs, Receptacles and Interlocks
Circuit breaking receptacles, plugs and connectors assure
complete circuit breaking under full rated loads. Equipment
grounding is provided by means of a separate pole which
makes contact before and breaks contact after the circuit
poles. The delayed action operation sequence is as follows:
Insert plug, turn left, push in to make electrical contact then
turn right to prevent accidental disconnection. To withdraw
plug, the reverse procedure is followed which allows time for
extinction of the arc and cooling before the plug can be
completely withdrawn.
Ordering Information
Delayed Action Receptacles
Explosion Proof: Div. 1, Class 1, Groups C and D
H142 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Hazardous Location
H
Russellstoll ®
412031.H08 HDUTY 3/5 3/14/03 7:05 PM Page 142
Amp D R S T U V Y Z
20 Angle 2.56" 6.12" .28’ 3.75" 3.75 3" 5.37"
30 Straight 3.87" –– 8.62" .34" 6.12" 5" 5.25" 6.75"
Angle 3.06" 7.37" 8.37" .28" 3.50" 5.50" 4.75" 4.75"
60 Straight 3.87" –– 9.25" .34" 6.12" 5" 5.25" 6.75"
Angle 3.87" 9" 9.25" .34" 6.12" 5" 5.25" 6.75"
Delayed Action Receptacles (EFS and DA)
D
Z
S
V
U
Y
T
S
RZ
4
3"
5.37" 3.75"
MTG
3.75" MTG
.28" Dia.
2 MTG
Holes
3.75"
3"
4.75" 5.5"
3.75"
MTG
3.75" MTG
.28" Dia.
2 MTG
Holes
5.75"
4.12"
5.12"
7"
3.62"
4.75"
2.56"
a.
3.12"
5.37"
3.31"
2.56"
.81"
2.75"
1.75"
2.12"
Dia.
3.12"
Receptacle Housings – EFS – Cast copper free aluminum;
DA – cast iron, corrosion resisting baked enamel finish.
Plug Housings – 20 Amp –steel, cadmium plated; 30 Amp –
cast iron; 60 Amp – steel and aluminum, natural finish. Plugs
are furnished with aluminum alloy cable clamp and neoprene
cable bushing.
Connectors – Cast aluminum, natural finish. Furnished with
aluminum cable clamp and neoprene cable bushing.
Flush Plates – Brass, polished chromium finish.
Outlets – Furnished with one outlet top or bottom as follows.
20 Amp – f"; 30 Amp – 1", 60 Amp – 1d". Additional or
larger outlets charged extra. Maximum conduit sizes, four
ways as follows:
20 Amp – 1", 30 Amp – 1d"; 60 Amp – 2". Single gang-top
and bottom only, two gang – one per gang top and bottom
and one on each side. Specify size and location.
Cable Bushing – oil resistant, neoprene strain relief cable
bushing regularly furnished with hole size as listed. Other
hole sizes available at no extra cost if specified on order. See
page H144.
Surface Gang Units – EFS available and can be furnished in
2 gang units or in combination with other like devices.
Approvals – (20 & 60 Amp)
E10919
Dimensions
Surface Mount Receptacles Flush Mount Receptacles
Connector Plug
Type EFS (20 Amp) Straight Type DA (30 & 60 Amp) Straight Type EFS
20 Amp Plug 30 Amp Plug 60 Amp Plug
Specifications
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H143
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 143
Hole Diameter Hole Diameter 20A
for Cable Cat. No. for Cable Cat. No.
.312" SG05 .563" SG25
.375" SG1 .594" SG2B
.438" SG15 .625" SG3
.500" SG2 .687" SG3A
.531" SG2A .750" SG4
Delayed Action Receptacles (EFS and DA)
Material – Oil Resistant Neoprene.
Note: Cable outside diameter should be at or slightly less than bushing I.D. Bushings can compress approx. 10%
at installation.
To Order add suffix as examples: 4466/SG3
Part No. Finish Used on Cat. No.
F19054C Chrome Plated 4445
F19054D Natural Finish 4464
Flap Cover Assembly
For 20 Amp Delayed Action Circuit Receptacles
Part No. Used on Cat. No.
F24853C 4466
F24853D 4467
Combination Gland Nut and Cable Clamp
For 20 Amp Delayed Action Circuit Plugs
Provides extra clamping protection in hard service
applications.
Material – Cast aluminum alloy, natural
finish
Cable Bushings
For Explosion Proof Plugs & Connectors
To order non-standard bushing, add cable bushing number to end of catalog number. This is furnished at no additional cost at
time of order. For 60 A devices, see J-line 60A chart on page H41.
Accessories
H144 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 144
Rating Explosion Proof
Switch Hp Amps & Dust TIght 2 Gang
1.5/2.0 15 4411S7 4421S7
Single Pole / Single Throw 1.0/2.0 20 4411S27 4421S27
2.0/2.0 30 4411S3 4421S37
1.5/2.0 15 4412D7 4422D7
Double Pole / Single Throw 1.0/2.0 20 4412D27 4422D27
2.0/2.0* 30 4412D37 4422D37
Switches
EFS Series
20 Amp, 575VAC
30 Amp, 250VAC
Notes:
Switches with other than listed ratings can be furnished. Prices and information on application.
* 1 Hp, 460VAC, 2 HP, 115 or 230VAC, 250 or 600VAC rating also applies to 30A switch. Brass construction also available - consult Technical Services.
Specifications
Enclosures – Cast copper-free aluminum, epoxy
powder coated finish. Can be furnished with lock-type
cover to permit locking in either “on” or “off” position.
When so required, add suffix “L” to catalog number. See
price list.
Can be furnished in two gang units and in combination
with other Russellstoll explosion proof receptacles.
Outlets – Unless otherwise specified, furnished and one
f" outlet per gang, top or bottom. Maximum conduit 1":
single gang – top and bottom only, multiple gang – one
per gang top and bottom and one each side. Specify
size and location.
Approvals – 844 Standard
E10765
Dimensions
4.62"
5.38"
2.56"
4.75"
3.00"
3.75"
6.81"
4.75"
6.12"
Explosion Proof: Div. 1, Class 1, Groups C and D
Dust-Tight: Class II, Groups E, F and G
In hazardous locations, these switches are applied to control a variety of lighting, power and machinery branch circuit loads.
They can also be used with Russellstoll hazardous locations receptacles for maximum control sytem flexiblity.
Ordering Information
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H145
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 145
Description Cat. No.
Ground cup w/ cover* GCC1
Ground cup with out cover* GC1
Replacement contact tip** F06146
Aerospace / Industrial Static Ground Devices
Static grounding receptacles are used in Airport and Aerospace installations worldwide during fueling, testing and
maintenance procedures. Normal mounting is concrete / tarmac floor inset, threaded onto copper ground rod.
Heavy Brass construction cup includes optional cover and receptacles contact pin.
Accommodates a wide variety of single contact (copper on steel wire) static ground wire
clamps in service.
Static Ground Receptacle
* Hub is tapped for f" -10
** Hub is tapped for d" - 13
F07073
(cover only)
Ordering Information
H146 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 146
Safe Ground Indicator System (GSUL)
Class I, Groups C and D NEMA 7
Class II, Groups E, F and G NEMA 9
Weatherproof Reel
Cat. No. SGR25
Grounding Clamp
to Fuel Carrier
Cat. No. SGC2
Explosion-proof
Sealing Fittings
Explosion Proof
Tumbler Switch
Cat. No. 4411S7
Explosion Proof
Safe Ground Indicator
Cat No. GSUL-2-SS
To Ground Electrode
Instant signal for safe ground
Ground indicators are designed for grounding tank vehicles,
carriers, drums or similar applications for dissipating ever-
present static electricity. The establishment of a safe ground
is indicated by the two parallel connected green signal lights.
Two lights are used for continuity. In case one lamp burns out
visual indication of safe groundings will be maintained.
Intrinsically safe circuitry
GSUL devices have an Intrinsically Safe (low energy) Ground
Sensing Circuit, which does not have sufficient electrical
energy to cause ignition in classified Hazardous Locations.
In use, the sensing Circuit extends through the grounding
clamp and its connection to the Ground Indicator, the metal
portion of the vehicle between the jaw terminals of the clamp
and earth ground electrode.
Pumps will not operate until a safe
ground is established
A control relay is included for interlocked control of pump
motor at the loading platform. The electronic control circuit
will be de-energized while the green lights are off. Attaching
the clamps to the tank will close the interlocking contact and
energize the control circuits to the motors.
Applications
Volatile or classified areas such as:
Tank Farms PetroChem
Cosmetics Grain Mills
Vehicular or Rail Transport
Typical Installation
Loading Rack Illustration suggests a typical installation which includes an Explosion Proof Switch: Explosion-Proof Sealing Fittings: Weathertight Reel; and the GSUL-2-SS Safe
Ground Indicator with special 2 wire grounding clamp.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H147
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 147
Safe Ground Indicator System (GSUL)
TB1
L1 GL2 CN.O. N.C.
123456G
G
G2
G1
C
TB3
Ground Electrode Connection (1 electrode required)
not provided by Russellstoll
Two-Conductor Cable
Weathertight Reel
Grounding Clamp
Cat. No. SGC2
Remote Indicator Pilot Light
(Optional)
Mounting
Feet
N.O. - N.C. Relay Contacts
1/3 H.P. 10 Amp 120 VAC
1/2 H.P. 10 Amp 240VAC
To 115 Volts,
60 Hz Ground in explosion-proof
portion provided by conduit
system
GSUL Safe Operating Features
Unit shown with
covers removed
Basic Installation
• The Green Lights glow when a Safe
Ground is established. Lamp life is
approximately 20,000 hours.
• Intrinsically safe … simplified circuitry.
• Furnished with two redundant parallel
indicating pilot lights mounted on the
enclosures. The unit may be ordered
without the lights where remote visual
indication is desired.
• Unit is furnished with an integral,
intrinsically safe wiring compartment
provided with an approved strain
relief fitting for connection of cable
from the grounding clamp.
• The actuating and control circuits are
solid state units mounted on a
removable printed circuit board.
• Components are well protected
against moisture.
• A Control Relay is provided for
interlocked control of Pump Motor at
a loading rack.
• A special Grounding Clamp is
available for use with the Ground
indicator Unit, order SGC2.
• New grounding clamp (Cat. SGC2,
replaces old cat. # GSUC) provides
dual isolated tip contacts in a very
heavy duty cast aluminum handle
design.
H148 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 148
Catalog No. Description Dimensions
GSUL-2-SS* Safe Ground Indicator with Indicator Lights
(*furnished with lamps) (120V supply)
New: 240V version available
GSUL2SS-240
Contact Technical Services
SGC2 Grounding Clamp
(Replaces GSUC)
P12G2 Remote Indicator Light – Surface mounting
duplex pilot light with two green lens.
Explosionproof.
Consult Customer Service for
Availability and Delivery.
SGR25** Weathertight Reel – Retracing Reel with 25 ft.
SGR50 of 2 conductor #12 AWG type SO cable.
SGR75 Note: 50 foot and 75 foot versions available.
(Replaces AR253)
Spare Parts
Description Cat. No.
Printed Circuit Board C13662
Control Relay** F30674
Lamp for GSUL-2-SS 310993
Ground Clamp Repair Kit GX2TK
Safe Ground Indicator System (GSUL)
4.5"Approx.
.43"
Indicating
Lights
(Green)
.69"
3.56"
.75"
5.25"
3" MTG
.75" NPT
.75" NPT
Conduit
10.25"
MTG
9.25"
.3" Dia.
Hole
.75" NPT
Conduit
.75" Max. Conduit
Russellstoll
Russellstoll
Russellstoll
CAT. #
CAT. #
CAT. #
SGC2
SGC2
SGC2
.14
6 PLS
2X Conductor
Termination Set Screws
2x "Rue Pin" pivot
pin locking
Cable Entry
Clamp & Screw
5"
5.37"
4.75"
3.75"
MTG.
3"
3.75"
MTG
1" Max. Conduit
Top and Bottom
13" Dia.
7.5"
3.37"
1.25"
3" Sq.
8.5"
Rad.
1.56"
.56" Dia. MTG Holes
.75" Female Thread
Line Entrance
14.75"
8.25"
2.5"
9.75"
3.37" 6.37"
.37"
3"
2"
4 Holes Pivot MTG (optional)
2 Holes Rigid MTG
.37"
6.87"
4 Sq
Notes:
** Ground clamps must be ordered separately.
Ground Indicators complete with Control Relay. When unit is required
without control relay add suffix “X” to catalog number.
Outlets – Regularly furnished tapped f" NPT as per diagram on opposite
page.
Enclosures – Cast copper free aluminum, epoxy powder coated.
** Relay contacts are rated 1/3 H.P., 10 Amps, 120VAC; 1/2 H.P.,
10 Amps, 240VAC.
Ordering Information
Safe Ground Indicators are designed to operate on 110-120 VAC, 50/60 Hz circuits, with grounding being made through use
of a 2-conductor #12 AWG Type SO cable.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H149
Hazardous Location
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 149
The toughest construction in
thermoplastic safety, durability and
performance by design, in UL94-VO
flame rated DuraV material. With
DurOring sealed pins, sleeves and
interiors watertight even unmated. A
30 & 50A unique circuit breaker
interlock line in DuraV is the best
choice in all standard voltage
polarization options through 600VAC
(Interlock to 480VAC)
Otherwise similar to the DuraGard,
Spec Grade refers to blue Lexan
plugs only made to the same original
FS/FD design standards as
DuraGard, in UL94-5VA flame rated
material. Spec Grade features
DurOring sealed pins, sleeves and
interiors, watertight even unmated.
Spec Grade devices have been
superceded by DuraGard ratings for
OEM use.
The original 15/20/30A computer
system connectors, the FS/FD line in
aluminum continues in MRO usage.
Many installations can also mate
directly or convert to DuraGard units.
Our large installed base can be
supported with any construction and
product options. Convert to
DuraGard when possible.
The original 60A main power
computer system connector, Angle
Type plugs are also available in
specialty UL94-V0 material. (Alum.
Connectors) As part of the MRO
usage 30-200A Angle Type Line, the
60A connector is still commonly used
today. Other lines such as MaxGard
should be used for changeout when
possible.
For DP/Computer System
Applications, a special MaxGard
polarization reflects DP installations.
Special thermoplastic housing and
back handle are supplied for these
applications. Use wherever 4P5W
installations are required.
Thermoplastic International standard
309-2 or CEE-17 type connector
lines usage is growing, especially in
OEM, export, and standard
performance applications. The IP67
style is watertight when mated and
directly interchangeable with other
manufacturers. International
designations shadow U.S. ratings:
20/16, 30/32, 60/63 and 100/125.
IP67 devices have screw collars or
flap/screw covers, with catalog
number “W” suffixes.
Computer System Interconnections – Overview
DuraGard
to 4P4W
20 thru 50A
SpecGrade
to 4P4W
20 & 30A
FS/FD
to 3P4W
15 thru 30A
Angle Type
to 3P4W
60A use
MaxGard
30A to 4P5W
IEC: IP67
to 4P5W
20 to 100A
Defined
Telephony Equipment
Switching Rack Systems
Power Distribution Units
Test & Laboratory Equipment
Mainframes from 30-270A
Peripherals
Data Storage Devices
Military or Critical Power Supplies
Typical Application Groups
Russellstoll Line Selections for Outdoor (and Indoor) Applications
• Any application where electrical connections must be
protected from humidity, water, condensation and/or dust
ingress to the wiring compartment and contacts.
• Cable-to-connector sealing and device locking designs are
critical.
• Thermoplastic connectors preferred: some with aluminum
conduit grounded shell.
• Connection integrity needs are absolute; Data Center
systems cannot go down.
• Underfloor Data Center applications and wall mount
installations.
H150 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 150
SERIES* FS/FD Spec Grade DuraGard®Spec Grade
Available Ranges (Amp) 20 & 30 20 & 30 20, 30 & 50 30 (IEC)
Safety Grade™ UL Flame rated UL94-V0
High-Temp Thermoplastic Aluminum UL94-5VA UL94-V0 UL94-V0
Easy-to-Wire
✔✔
Rear loaded interiors
Single Rated Safety 20A 20A 20A
Voltage Polarizations 30A 30A 30A
50A (9h – IEC)
Waterproof O-Ring Seal ✔✔
(pins, sleeves & interiors)
2nd Internal Ground Lug (optional)
(cable shielding alt.)
External Cable Clamp ✔✔
External Gland Nut Lock ✔✔
Computer System Plugs, Connectors and Receptacles
Over 30 years ago, Russellstoll offered the first pin and
sleeve connectors that met the demanding needs of the
Data Processing industry and we’ve been leading the way
ever since.
The expanding technology of the Computer System Industry
is creating more sophisticated applications which require a
safe, reliable connection that exceeds the tough demands of
today’s applications. Russellstoll’s commitment to excellence
offers you that and more... Safety, Durability, Reliability and
Performance on our complete line of plugs, receptacles and
connectors.
Pin & Sleeve power connections are chosen for Computer
Systems interconnections because of the absolute
performance required in today’s mainframe and peripheral
installation. Pin & Sleeve connections have been proven to
be 1- times more reliable in service than any bladed device.
Data centers stay in service, because Russellstoll stays
connected.
E2630
LR14096
For TüV listed devices, contact Technical Services.
TüV
Quick Selection Chart
* 60A devices are specially designed versions of Russellstoll Angle Type (7328DP)
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H151
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 151
Computer System Plugs, Connectors and Receptacles – Ordering Information
15/
20
Amp
2P/
3W
3P/
4W
30
Amp
50
Amp
20
Amp
30
Amp
50
Amp
30
Amp
4P/
5W+
Plugs Connectors Receptacles
Angle Type
MaxGard
Note: All 20A devices are compatible. 30A FS/FD receptacles and connectors will accept all styles of mating plugs.
** For a more complete listing of UL 94-V0 rated devices, consult DuraGard information on Pages H44-H54.
** Consult Factory for additional cable bushing sizes not listed.
7328 DP series thermoplastic can replace 7328 metallic.
30A FS/FD Aluminum plugs may not directly exchange with DuraGard plugs. FS/FD metal mating devices must be used.
Standard 0.750 Bushing.
DuraGard receptacles and connectors 30/50A will accept only DuraGard or Spec Grade. FS/FD Aluminum 30A plugs must be used with FS/FD metal connectors or receptacles..
^ Angle Type Line
+ MaxGard Line for further information see pages H9-H29.
Requires 3711A conduit FD box or 3781A DSFD Box (50A).
H152 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Special MaxGard®
Special Angle Type
60
Amp
See Bushing
Plug Std. Chart
Safety Cable** FS/FD• Spec Grade DuraGard®FS/FD DuraGard®FS/FD• DuraGard®
Voltage Polarization Bushing Aluminum UL94-5VA UL94-VO* Aluminum UL94-VO* Aluminum UL94-VO*
Up To 0.625" 3720DP (0.375)
600 VAC/ 0.455" 3720 3720DP/0455 9P23U0 3913 9C23U0 3743 9R23U0W
250VDC 0.405" 3720DP/0405
0.625" 3720DPU1 (0.375)
125VAC 0.455" 3720U1 3720DPU1/0455 9P23U1 3913U1 9C23U1 3743U1 9R23U1W
0.405" 3720DPU1/0405
0.625" 3720DPU2 (0.375)
250 VAC 0.455" 3720U2 3720DPU2/0455 9P23U2 3913U2 9C23U2 3743U2 9R23U2W
0.405" 3720DPU2/0405
Up To 0.760" 3750DP
600 VAC 0.700" 3750 9P33U0 39339C33U037539R33U0W▼■
0.625"
Up To 1.000"
600 VAC 0.925" 9P53U0 9C53U0 9R53U0W
0.750"
Up To 0.688"
600 VAC/ 0.625" 3730 3730DP/0625 9P24U0 3914 9C24U0 3744 9R24U0W
250 VDC 0.606" 3730DP
Up To 1.100" 3760DPG/1100
600 VAC 1.000" 3760 3760PDG/1000 9P34U039349C34U0◆■ 37549R34U0W▼■
0.875" 3760PDG/0875
0.760" 3760DPG0760
Up To 1.000"
600 VAC 0.925" 9P54U0 9C54U0 9R54U0✷▼
250 VDC 0.750"
Up To 1.375" 7328DP/1375
600 VAC 1.188" 7328-78^ 7428-78^ – – SCF7324-78
1.020" – 7328DP†
0.750" – 7328DP/0750
3øY
120/208 0.775" DS3516MPDP+ DS3516FP+ DS3516FR+
VAC
3P/
4W
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 152
FG H I JKM
20 AMP 4a" 3b" 2e" 1g" 1a" 2b" 2d"
FS/FD 30 AMP 4a" 3b" 2e" 1g" 1c" 2f" 2e"
Angle Type 60 Amp 3 d" 2g" 3d" 2g" 2d" 6"
(Metallic)
20 Amp 4a" 3b" 2e" 1g" 1d" 2" 3a"
DuraGard®30 Amp 4a" 3b" 2e" 1g" 2d" 2f" 4a"
50 Amp 4a" 3b" 2e" 1g" 2d" 2f" 4a"
ABC
20 Amp 3e" 2" 2b"
FS/FD 30 Amp 3f"2b" 2c"
Angle Type DP 60 Amp 8" 2d" 3f"
(Thermoplastic)
20 Amp 3b" 2a" 2a"
Spec Grade 30 AMP 5" 2c" 3e"
DuraGard®
50 AMP 5b" 2c" 3e"
DE
20 Amp 4" 1g"
FS/FD 30 Amp 4e" 2a"
Angle Type 60 Amp 9a" 3d"
(Metallic)
20 Amp 4a" 1g"
Spec Grade 30 AMP 5e" 2a"
DuraGard®
50 AMP 5e" 2a"
Computer System Plugs, Connectors and Receptacles – Dimensions
A
B
C
D
E
Plugs Connectors
Receptacles
(DuraGard shown)
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H153
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 153
Plug/ Cat. No.
Connector Tapped
Size Hole Size FS/FD Spec Grade DuraGard®
20 Amp d" FSA11 – 9X2C50
f" FSA12 – 9X2C75
30 Amp d" FSA21 – 9X3C50
f" FSA22 – 9X3C75
1" FSA23 –
50 Amp f" – – 9X5C75
1" – – 9X5C10
60 Amp f" JPA62 –
Angle Type 1" JPA63 –
1b" JPA64 –
1d" JPA65 –
Computer System Plugs, Connectors and Receptacles – Accessories
Cat. No.
Receptacle size Single Gang Double Gang
20, 30 & 50 Amp 3711A 3712A
60 Amp* JB6-1
50 Amp 3781A 3782
Conduit Boxes (For Surface Mounting)
Angle Adapter
* Various mounting options available.
4” deep (not shown)
Conduit Adapter
Catalog No. 3711A Catalog No. 3712A
Kit includes gland nuts for plugs or connectors.
Cat. No.
Receptacle size 45 Degree 20 Degree
20, 30 & 50 Amp 3678A –
60 Amp* JAA6-45 JAA6-AB6
Mounts to conduit boxes to angle receptacle downward, for easier access, no
moisture retention on surfaces and better plug-cable drop bend relief.
* Various mounting options available.
All conduit boxes/Angle Adapters are copper free, cast aluminum, epoxy powder coat finish.
H154 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 154
Cat. No.
Male Interior Assembly Female Interior Assembly
Amperage Voltage Polarization
125 VAC 9XM23U1 9XF23U1
2P3W 20 250 VAC 9XM23U2 9XF23U2
Thru 600VAC/250 VDC 9XM23U0 9XF23U0
2P3W 30 Thru 600VAC/250VDC 9XM33U0 9XF33U0
2P3W 50 Thru 600VAC/250VDC 9XM53U0 9XF53U0
3P4W 20 Thru 600VAC/250VDC 9XM24U0 9XF24U0
3P4W 30 Thru 600VAC/250VDC 9XM34U0 9XF34U0
3P4W 50 Thru 600VAC/250VDC 9XM54U0 9XF54U0
Interiors with ground straps are specials.
Spec Grade DuraGard Spec Grade DuraGard
Item Color Blue Yellow Blue Yellow Black
Plug/Connector Amperage 20A 20A 30A 30A 50A
Gland Nut C17077C C17077A C17076CX C17076AX C17076BX
Nylon Locking Screw N/A NA B16983 B16983 B16983
Bushing, Clamp, Nut, and Screw Kit B17019CPR B17019APR B17018CPR B17018APR B17018BPR
(Inc. Nylon Locking Screw – 30/50A)
Bushings To Spec To Spec To Spec To Spec To Spec
Glide Washer 863-8 863-8 500RS 500RS 500RS
Gland Nut Assembly B17019CR B17019AR B17018CR B17018AR B17018BR
Note: Minimum purchase quantities apply.
Computer System Plugs, Connectors and Receptacles – Accessories
Plug/Connector Replacement Items
Replacement Interiors
Note: For replacement bushings, see DuraGard Section, pg. H51.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H155
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 155
Computer System Plugs, Connectors and Receptacles – Specifications
Performance – Electrical
Dielectric Voltage 3,000 Volts
Withstand
Max. Working 6000 volts RMS minimum
Voltage (creepage distance and minimum
clearance per UL 840)
Circuit Interrupting/ UL listed and CSA certified
Load Breaking for circuit interrupting at full rated
current.
Temperature Rise Max. 30°C temperature rise at full
rated current after 50 cycles of
overload at 150% rated current at
.75-PF.
Shrouded Contacts Complies with California Code
Title 8, Art. 51, S2510.7(b) for
devices exceeding 300 VAC
Horsepower Per NEC 430-151 ratings
Performance – Mechanical
Impact Resistance Per UL 1682 Paragraph 34
Cord Round portable service
Accommodation cords per UL Std. 62 & CSA
C22.2 No. 49.1
Terminal In accordance with UL1682
Identification
Cable Pull Out In accordance with UL1682
Force
Product Identification label and
Identification molded in name
Lockout/Tagout Lockout/Tagout hole in 30/50A
DuraGard®plug complies with
OSHA Reg. 29 CFR 1910.147 (V0
30 & 50A plugs only)
Performance – Environmental
Moisture Per UL1682 Paragraph 49.
Resistance Watertight flap screw cover on
receptacle, O-Rings on all V0/5VA
pins and sleeves (excludes 60A)
Flammability V0 / 5A per UL94 (DuraV also 5VA
in some apps.)
Operating
Temperatures
Chemicals Resists standard industrial
hydrocarbons, acids, bases and
solvents. (DuraV & Metal)
Approvals
Conforms to NEMA 4, 4X & 6. (DuraGard and Spec Grade)
Contact Technical Services.
®
TüV
Materials
FS/FD Spec Grade DuraGard®Safety Grade
Contact Carrier Interior Thermoset / Thermoplastic) Arc resistant UL94-V0 Arc resistant UL94-V0
(20A & 30A) phenolic Thermoset phenolic Thermoset
Housing, Gland Nuts Cast Aluminum Lexan®UL94-5VA, DuraVUL94-V0,
Screw Collar Rings High Impact Thermoplastic High Impact Thermoplastic
O-Rings Buna-N (Nitrile) Buna-N (Nitrile)
Contacts: Pins & Sleeves Brass Brass CDA 360 Brass CDA 360
Hinge Pins (Receptacle) Stainless Steel Stainless Steel
Terminals Brass Stainless Steel Stainless Steel
All Hardware Stainless Steel Stainless Steel Stainless Steel
Gland Glide Washer Brass 20 Amp - Nylon
(or Internal Cable Grip) 30 & 50 Amp - Aluminum
– Nylon
Cable Clamp Bushing Neoprene Neoprene Neoprene
Lexan®is a registered trademark of GE.
VO* 5VA Metal*
Maximum 95°C 130°C 130°C
Continuous (230°F) (266°F) (266°F)
Minimum -40°C -29°C _40°C
W/o Impact (-40°F) (-20°F) (-40°F)
H156 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 156
Computer System Plugs, Connectors and Receptacles – Data Center Installation
Benefits
Saves rewiring costs in a facility when installing small-
sized, lower current machines using existing electrical
service.
Quickest and most cost effective way to expand or
reconfigure a single service with multiple service outlet
combinations possible at every power drop.
Safest way to operate: UL Listed 22kA interrupt capacity
interlocked circuit breaker protection for each branch
outlet receptacle, in a NEMA 4 enclosure.
Applications
Data Processing: CPU / Disk Arrays / Peripherals new
smaller multiple units.
Industrial / Manufacturing Lines: reorganization,
process reconfiguration.
Portable Power: Machinery, Tools, Test and Diagnostic
equipment.
Electrical and Safety Features
One: 250VAC 3p4w 60A male inlet feeding Two: 250VAC
3p4w 30a IEC 309-2 (9h Blue) female receptacle outlets,
each protected by 22kA IC circuit breaker; each
mechanically Interlocked.
Power is manually energized only after plug is inserted;
externally visible trip indicator handles on each Interlock.
Automatic Shut Off when plug is removed before contacts
disengage; ground sleeves Make first, Break last.
Patented “Trip-Free” Safety Mechanism where outlets are
not powered unless plug is inserted.
Full NEMA rated UL 489 listed 22kA Circuit Breakers,
available to 480V at 30 Amps. 60 Amp and other options
available.
Mechanical and Safety Features
All internal wiring is complete: a Drop-In, Plug-In specified
device.
DP Underfloor (Horizontal) installation standard; vertical or
other mounting conventions optional.
Electrostatic epoxy powder coat gray finish over 14
gauge steel NEMA 4 welded enclosure with gasketed
access cover.
Screw cover protects outlet receptacles (flap cap option).
Long life stainless steel & nylon external hardware,
copper-free aluminum castings,
O-ring seals (to device spec) & brass electrical contacts.
Custom Products:
Interlocked Branch Distribution Centers
Utilize an existing higher amperage service and split it into
multiple lower current service outlets. The outlets are
individually interlocked with circuit breaker protection.
Branch Distribution Centers are UL & CSA listed and can be
configured for many inlet/outlet combinations.
Standard Dual Configuration:
• 60A Male Inlet
• 2 - 30 A Individually Interlocked Female Outlets, each
Circuit Breaker Protected.
• Heavy duty NEMA 4 welded, gasketed enclosure.
© 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com H157
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 157
Computer System Plugs, Connectors and Receptacles – Data Center Installation
Ordering Information
Inlet Side Outlet Side*
250VAC, 60A Mating 250VAC, 30a Mating
Cat. No. Male Inlet Connector Outlet Receptacle Plug
ER206M39 7528 Spl. 7428-78 RS430MM9W (x2) RS430P9WV0
(External mating Plugs & Connectors sold separately)
Other Configurations available. Consult factory or your Russellstoll Representative
* IEC 309-2 configuration, 9h, 3P4W
Outline Dimensions
Schematic Diagram
H158 © 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com
Computer Systems
H
Russellstoll ®
412031.H09 EFS 3/5 3/14/03 7:08 PM Page 158