Rittal RimatriX5 Catalog Brochure

2016-10-06

: Pdf 155276-Brochure 155276-Brochure B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 122 [warning: Documents this large are best viewed by clicking the View PDF Link!]

Rittal IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
Section 1 ............................................... Pages 3-11
Enclosures
Section 2 .............................................. Pages 12-51
Cooling
Section 3 .............................................. Pages 52-73
Monitoring and Security
Section 4 ............................................ Pages 72-99
Power
Section 5 .............................................. Pages 100-113
Tech Notes
Section 6 .............................................. Pages 114-117
Table of Contents
RimatriX5 IT Solutions from Rittal
2 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures –
It all starts with a diverse range of
cabinets, racks and boxes for network
and server applications. Whether the
leading edge TS8 or the innovative
TE 7000, Rittal has the cabinet solution,
guaranteed to deliver time and
money savings.
Cooling –
From passive air to liquid cooling,
Rittal provides all the required
components and systems for
customized, reliable climate control.
Monitoring –
With system-wide monitoring,
management and configuration software,
preventive intervention and the shortest
possible response time to critical issues
is made possible.
Security –
For protection against the most common
data and computer center threats, Rittal
offers comprehensive security solutions
including the CMC-TC monitoring system.
Power –
Fit for the future, Rittal’s power
management solutions bundle maximum
availability, redundancy and scalability into
a single system while reducing installation
and operating costs.
For important IT decisions, go with
the company that holds the experience
knowledge and leading-edge products
for virtually every application.
For total IT solutions…go with Rittal!
Whether in small businesses or major enterprises, the demands placed on the IT
infrastructure are unrelenting. In today’s mission-critical environments, no one has
the expertise to protect and organize your vital IT equipment better than Rittal. As the
world’s leader in enclosure solutions, Rittal continuously delivers innovative and reliable
products to ensure high-performance information technology. And with RimatriX5, Rittal
provides peace of mind for the most important infrastructure issues facing data center
and facility managers.
Product Overview
RimatriX5 IT Solutions from Rittal
RimatriX5 IT Solutions 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
TS8 Server Enclosures
Designed specifically for the data center,
the TS8 is a modern enclosure offering
strength and stability for virtually any
server environment. Its patented 16-fold
continuously welded frame delivers 30%
more dimensional stability, high load-
carrying capacity and maximized
internal volume.
• Frameprofile
The symmetrical design ensures an
absolute maximum of useful rack volume
and permits scalable suite options for
optimized space utilization in all planes.
• Interiorconfiguration
Depth-adjustable 19" (482.6 mm)
mounting angles permit configuration
of complex server architectures. And
with a load capacity of 3200 lb
(1450 kg), there are virtually no
restrictions for interior configurations
of the rack.
• Surfaceprotection
For optimum surface treatment and
enhanced corrosion protection, Rittal
uses the electrophoretic dipcoat priming
process on all TS8 enclosures.
• Passiveventilation
The perforated front and rear doors
offers a 64% ventilated surface in their
punched plate sections for optimum
airflow to the installed hardware
components which meets or exceeds
server manufacturer specifications.
TE 7000 Network Enclosures –
Ideal for network applications, this
frameless enclosure is perfect for quick,
cost-effective cabling. Its high-load
capacity, versatile framework delivers
optimum accessibility and maximum
usable interior space.
• Simpletoinstall
Accessories for power supply, security
and climate control mount easily and
quickly to reduce installation costs.
• Maximumcapability
Load capacity up to 880 lb (400 kg)
for the network enclosure and 1400 lb
(635 kg) for the server enclosure.
The long-term performance of an IT infrastructure is dependent on the coordinated
interaction of individual components. With RimatriX5 server enclosures, integration
of climate control, power and security solutions is simple. Innovative, modular designs
maximize internal space and load bearing capacity while making the addition of new
active devices and additional enclosures simple and cost effective.
Product Overview
RimatriX5 IT Enclosure Solutions
4 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
Wallmount Enclosures –
For small networks or floor distributors,
wallmount enclosures from Rittal come in
numerous configurations to meet virtually
any network equipment need. Available
off-the-shelf, completely assembled,
wallmount enclosures contain numerous
cost-efficient, customer-oriented features
like viewing doors, cooling fans and
cable collecting rails.
Data Racks –
These torsion-resistant designs serve as
mobile or stationary housings for moni-
tors, servers, keyboards, printers and other
network components.
SpecialtyEnclosures–
With a legacy of innovation, it is no surprise
Rittal offers leading edge solutions for new
and demanding market requirements.
Rittal delivers proven solutions for critical
applications, including:
• Co-locationenclosures
• Liquidcoolingenclosures
For more information contact Rittal.
RimatriX5 IT Solutions 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
Liquid Cooling Package (LCP/LCP Plus) –
This high density cooling solution utilizes
air/water heat exchangers providing
uniform, effective and affordable cooling
for servers and similar IT equipment.
Key parameters and features include:
• Usefulcoolingperrackof12to40kW
• Fanairthroughputupto1412cfm
(2400 m3/h)
• ControllerforoptionalSNMPCMC-TC
for network monitoring
Rittal RimatriX5 solves the problem of
climate control for high heat losses per
rackwiththeLiquidCoolingPackage
(LCP)range.Extremelyhighheatloads
aredissipatedfromtherackviatheLCP
air/water heat exchanger. Additionally, this
system also allows temperature-neutral
expansion of the data center.
Perhapsthemostpressingissueintoday’sdatacenter,managementofheatandhumidity,
is paramount in maintaining a high-performing data infrastructure. Higher processing
speeds and the implementation of high-density blade servers has led to enclosure heat
densities of 20 kW and higher. RimatriX5 cooling solutions incorporate the industry’s most
comprehensive and advanced technologies to meet the requirements of the hottest running
data centers. Highly adaptable and easily scaled, data centers can leverage an array of
solutions that includes simple air cooling, heat exchangers or sophisticated liquid cooling
modules that provide direct liquid cooling to heat sinks on processors.
Product Overview
RimatriX5 IT Cooling Solutions
6 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
Chiller Systems –
Rittal chiller system provides central
chilling to support liquid cooling systems.
Separation of the chilling and cooling
processes permits temperature-neutral
expansion of data centers.
Air Conditioners –
Wallmount and roofmount air conditioners
from Rittal are highly dependable, flexible
and easy to operate. These versatile
systems incorporate microcontroller
technology and can be integrated with
remote monitoring systems for precision
control. This broad range of ready-to-install
systems can deliver cooling capacities
up to 4 kW.
Fans and Blowers –
A broad range of fan systems is available
to enhance airflow distribution in the rack
utilizing ambient air for cooling hardware
components.Underoptimumconditions,
fan systems are able to dissipate heat
losses of up to 5 kW in a rack.
RimatriX5 IT Solutions 7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
Power Distribution Units (PDU)
Providereliableandintelligentpower
distribution for equipment racks and other
data center applications. A broad range of
sophisticated solutions includes Switched,
SmartandMeteredPDUsthatallow:
local or remote monitoring; environmental
monitoring; remote configuration; and
SNMPalerts.
Single-PhaseUPSSmallCapacityTower
The Small Capacity Tower provides pure
sine wave output during battery operation
for smooth, continuous power. Buck and
Boost voltage regulation corrects incoming
voltage fluctuations so they do not affect
the performance of connected equipment.
Single-Phase UPS Line Interactive
TheRimatriX5LineInteractiveUPS
supplies clean, conditioned power to
connected equipment and resolves the
primary problems with incoming utility
power – outages, sags, surges,
brownouts and spike conditions.
Providingmorepowertoserversin
lessspace,theLineInteractiveUPS
can be obtained in rackmount or tower
installation configurations.
Single-Phase UPS Double Conversion
Unlikeothercommerciallyavailable
technologies, this double-conversion
on-line design assures that, in the event
of a utility power failure, there is zero
delay transferring to backup power.
The double-conversion architecture
incorporates both a rectifier and an
inverter to completely isolate the output
power from all input anomalies.
Miniaturization and the ever greater performance of hardware components place
new demands on modern power management solutions for the data center.
Ever-increasing data requirements and the introduction of new devices require
scalability and quick implementation of power management systems. With
RimatriX5, the need for redundancy, scalability and maximum availability are
bundled into a single system. Together, these solutions help to reduce operating
costs and boost the availability of the overall system.
The RimatriX5 power management and distribution product range is based on
implementing plug-and-play expansion, with no need to interrupt current operations.
Downtime is avoided and future operating costs are lowered.
Product Overview
RimatriX5 ITPowerSolutions
8 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
3-Phase RimatriX Modular UPS
Designed specifically for high-density
computing environments, the RimatriX
ModularUPSdeliversefcient,reliable
powerinonly6Uofrackspace.Thispower
UPSsolutioncanbeconguredtodeliver
higher density than competitive modular
solutions while dissipating one-third of
the heat.
Advanced Battery Management
RimatriX5UPSsolutionsincorporate
Advanced Battery Management (ABM).
ABM technology uses sophisticated
sensing circuitry and an innovative three-
stage charging technique that doubles the
usefulservicelifeofUPSbatterieswhile
optimizing battery recharge time. It also
provides up to 60 days notice of the end
of useful battery service life.
Data center and network operations center managers are under extreme pressure
to reduce costs while dealing with other operational realities such as expanding power
demands, increasing power costs and protecting mission critical applications with
backuppower.RimatriX5uninterruptiblepowersupplies(UPS)areofferedinavastarray
of designs to address all the needs of the ever-changing and growing data environment.
RimatriX5 IT Solutions 9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
CMC-TC –
The CMC-TC (Computer Multi-Top Con-
cept) is a complete security management
system for protection against unauthor-
ized access, vandalism and environmental
factors such as heat, humidity, smoke
and vibration. Fault and alarm messages
can be sent to defined service or security
management systems. Its modular concept
permits tailoring to individual requirements
while automatic sensor detection enables
plug-and-play expansion.
Climate Control –
Constant low temperatures are a prereq-
uisite for long service life. Rittal monitoring
and control systems monitor inside rack
temperature and make corresponding
adjustments to climate systems to ensure
reliable dissipation of heat loads.
Access Control –
In today’s environment of right-sized staff-
ing and remote monitoring, access control
is a critical factor in corporate security.
Rittal control systems enable door access
control with numerical codes, magnetic
cards, transponder technologies, smart
cards and biometric systems.
Video –
Compact cameras with integrated network
connections enable distribution and man-
agement of video data via the Internet or
through centrally installed software.
Monitoring and Remote Management
At-a-Glance –
Monitoring and controlling enclosure tem-
perature. Documenting the status of the
UPSbackup.Monitoringfanspeedand
performance. Scanning multiple rooms
through video surveillance modules.
Monitoring and managing data centers
requires a comprehensive solution that
provides simple interaction and ease of
control. RimatriX5 monitoring and remote
management solutions deliver a unique
combination of configuration software
and management software that allows
clear evaluation of numerous parameters
to allow preventive intervention and
crisis management to ensure uptime
and control costs.
• PowersupplymonitoringincludingUPS
• Climatecontrol
• Earlyfiredetection
• Firealarmandextinguishersystems
• Accesscontrolandmonitoring
• Roommonitoring
• Alarmsequenceconcepts
• Waterwarning
• Videomonitoring
• Remotemonitoringandmaintenance
services
The fail-safe security of the IT infrastructure is essential and assumed in today’s busi-
ness environment. Whether environmental or access concerns, security solutions must
be comprehensive and easily integrated into monitoring systems. RimatriX5 security
solutions provide a broad range of solutions capable of protecting servers and network
devices from heat, fire, humidity, vibration and numerous other environmental factors
that can impact performance or destroy the device. Access control modules incorporate
leading edge door control and video modules to secure data environments from
unauthorized personnel and visitors.
Product Overview
RimatriX5 IT Monitoring and Security Solutions
10 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Overview
1-Day Program –
Rittal will ship all eligible cabinets and
accessories, ready for customer configura-
tion, within 24 hours of order receipt. Fans,
electrical components, cable management
devices and other accessories can be
included.
3-Day Program –
Rittal will configure the ordered cabinet
so it is ready to use upon receipt at the
customer site. Eligible sidewalls and ac-
cessories will be configured to application
requirements and shipped within 72 hours,
ready to install.
A-Item Program –
A-Items are manufactured daily and
readily available.
Eligible RittalXpress cabinet and
accessory part numbers are highlighted
throughout the catalog as shown
below. Order forms are available at
www.rittal-it.com/rittalxpress.
Or call 1-800-477-4000.
The leader in server enclosure innovation now makes it easier than ever to obtain the
industry’s most advanced IT cabinet. Rittal customers can now take advantage of two
unique quick ship programs.
BlackcellsindicateRittalXpressproduct.
Blue cells indicate A items, generally available
off-the-shelfforimmediatedelivery.
Product Overview
RittalXpress Fast, Reliable Solutions
RimatriX5 IT Solutions 11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
RimatriX5 IT Solutions from Rittal
12 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Server Enclosures TS8 .................................................................................................................. 14
Network Enclosures TS8 ............................................................................................................... 16
LCP Enclosures ............................................................................................................................ 18
Network Enclosures TE 7000 ...................................................................................................... 19
SpecialtyEnclosures
TS8 Co-Location ............................................................................................................................. 21
Wallmount Enclosures
QuickBox Enclosures ...................................................................................................................... 22
ELNEMA123-PartEnclosures ...................................................................................................... 23
ELNon-NEMA3-PartEnclosures .................................................................................................... 24
ELNon-NEMA3-PartAccessories .................................................................................................. 25
TE Wallbox and Accessories .......................................................................................................... 26
FlatBox ............................................................................................................................................. 27
Accessories ..................................................................................................................................... 29
Networking Enclosures
Data Racks ...................................................................................................................................... 30
System Accessories
Index ................................................................................................................................................ 31
System Accessories ........................................................................................................................ 32
PermanentITavailabilityandreliabilityarecriticalcorporateissuesintoday’sITclimate.
For this reason, it is important to ensure stable conditions for your complex server
and software system architecture. While Rittal is known as a trendsetter in modern
technology, we continue to learn from our experience in order to anticipate your needs
today and into the future.
Our comprehensive range of products are based on more than 40 years of enclosure
expertise, wide-ranging in energy management and the development of pioneering
climate control concepts.
For this reason, Rittal’s enclosures offer the ideal platforms for merging all the
relevant technologies into complete IT infrastructure solutions.
Enclosures
RimatriX5 IT Solutions from Rittal
RimatriX5 IT Solutions 13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
36" 80 x 24 x 36 RAL 7035 light grey 9969.808
80 x 24 x 36 Sand texture black 9969.809
80 x 24 x 40 RAL 7035 light grey 9969.810
42U 40" 80 x 24 x 40 Sand texture black 9969.811
80 x 28 x 40 RAL 7035 light grey 9969.812
80 x 28 x 40 Sand texture black 9969.813
42" 80 x 24 x 42 RAL 7035 light grey 9969.814
80 x 24 x 42 Sand texture black 9969.815
Full Rear Door, Without Sidewalls
Attractive and Highly Functional
Rittal's TS8 server enclosure – A modern design that
features the utmost in strength for virtually any server
environment.
Design:
The TS8 server enclosure features modern, attractive
aesthetics perfect for a highly functional server
application.
Applications:
•Universalserverenclosures
•Multiplevendorenvironments
•Storageequipment
•Terminationequipment
•Networkequipment
Environments:
•Datacenters
•MDC/IDC
•Wiringclosets
•Officeenvironments
•Centraloffices
•Co-locationandapplicationenvironments
Features:
•Contemporary,sleekappearance
•Multiplevendorequipmentcompatibility
•Fulllineofaccessories
•Familyofsizesandstyles
•Excellentheatdissipation
•Strongframestructure
•Highlyfunctionalandstylish,valuepackedand
competitively priced
Designed specifically for the
data center, the TS8 is a modern
enclosure offering strength and
stability for virtually any server
environment. While intended for
the data center, it is just as well
suited as a stand-alone enclosure.
Rittal’s patented 16-fold continu-
ously welded frame delivers
30% more dimensional stability,
guaranteed to beat the competition
on strength alone.
Specifications
Frame System – Multi-Fold Frame Design:
•Steelframe–strengthandrigidity
•Torsionfreestructure
•Multipleinternalsurfacesandpointsformounting
•Maximuminternalvolumeforfootprint
•Externalaccesstoallinstallationpointsfordoors,
walls and baying
•Maximumloadbearingcapacity–3200lbs
(1451.5 kg)
•Singleorsplitreardoors
ExternalSurfaces–DoorsandWalls:
•Securetoexternalsurfacesofframe
•Doorscanbeeasilyremovedorreversed
•Sidewallscanbescrewedon,lockedinplaceor
hinged to provide side door access
•Internaldoorhingeandlockpointsformaximum
security
•Doorstiffenertostabilizedoorandprovideadditional
mounting surfaces
•Maximumperforatedareameetsorexceedsserver
manufacturer specifications for airflow
•Groundstudsonallsurfaces
•Externalsurfacesdonotaffectloadbearing
capacity – same ratings with or without panels
•AvailableinRAL7035lightgreyorsandtextureblack
•Fullyperforatedfrontandsplit-reardoor
Vertical Mounting Rails:
•Fullydepthadjustableandmaintainloadcapacity
regardless of where the rails are positioned
•Floatinginstallationsystem–verticalrailsarenot
secured to frame members or lateral support
channels; can be adjusted independently
•“Z”shaped,multi-foldprofile–highloadbearing
capacity and multiple mounting surfaces
•19"mountingcapacityin24"cabinets,19"and23"
mounting capacity in 28", 32" cabinets
•Umarkingsonfrontandrearsurfacesofeachrail
Key Accessories:
•Sidewalls
•DoorMountServerFanPanel
•BayingKits
•ToollessShelves–19"(482.6mm)Rackmount
•Casters
•CableManagementHardware–DRings,Velcro
Straps,MountingPlates,Manage-IT
•PowerStrips–15,20,30Amp;Verticalor
Rackmount
•CMC-TC–EnclosureMonitoringSystem
•BoltDownKits
•ToollessBlankingPanels
Enclosures
Server Rittal TS8
14 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Accessories Page
Sidewalls 38
Casters 41
Fans 58
Cable Management 33-36
 BlankingPanels 40
Shelves 48-51
Baying Kit 46
Bolt Down Kits 40
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
36" 48 x 24 x 36 RAL 7035 light grey 9969.816
48 x 24 x 36 Sand texture black 9969.817
24U 40" 48 x 24 x 40 RAL 7035 light grey 9969.830
48 x 24 x 40 Sand texture black 9969.831
42" 48 x 24 x 42 RAL 7035 light grey 9969.844
48 x 24 x 42 Sand texture black 9969.845
80 x 24 x 36 RAL 7035 light grey 9969.818
80 x 24 x 36 Sand texture black 9969.819
36" 80 x 28 x 36 RAL 7035 light grey 9969.820
80 x 28 x 36 Sand texture black 9969.821
80 x 32 x 36 RAL 7035 light grey 9969.822
80 x 32 x 36 Sand texture black 9969.823
80 x 24 x 40 RAL 7035 light grey 9969.832
80 x 24 x 40 Sand texture black 9969.833
40" 80 x 28 x 40 RAL 7035 light grey 9969.834
80 x 28 x 40 Sand texture black 9969.835
42U 80 x 32 x 40 RAL 7035 light grey 9969.836
80 x 32 x 40 Sand texture black 9969.837
80 x 24 x 42 RAL 7035 light grey 9969.846
80 x 24 x 42 Sand texture black 9969.847
42" 80 x 28 x 42 RAL 7035 light grey 9969.848
80 x 28 x 42 Sand texture black 9969.849
80 x 32 x 42 RAL 7035 light grey 9969.850
80 x 32 x 42 Sand texture black 9969.851
80 x 24 x 48 RAL 7035 light grey 9969.908
48" 80 x 24 x 48 Sand texture black 9969.909
80 x 32 x 48 RAL 7035 light grey 9969.910
80 x 32 x 48 Sand texture black 9969.911
88 x 24 x 36 RAL 7035 light grey 9969.824
88 x 24 x 36 Sand texture black 9969.825
36" 88 x 28 x 36 RAL 7035 light grey 9969.826
88 x 28 x 36 Sand texture black 9969.827
88 x 32 x 36 RAL 7035 light grey 9969.828
88 x 32 x 36 Sand texture black 9969.829
88 x 24 x 40 RAL 7035 light grey 9969.838
88 x 24 x 40 Sand texture black 9969.839
40" 88 x 28 x 40 RAL 7035 light grey 9969.840
47U 88 x 28 x 40 Sand texture black 9969.841
88 x 32 x 40 RAL 7035 light grey 9969.842
88 x 32 x 40 Sand texture black 9969.843
88 x 24 x 42 RAL 7035 light grey 9969.852
88 x 24 x 42 Sand texture black 9969.853
42" 88 x 28 x 42 RAL 7035 light grey 9969.854
88 x 28 x 42 Sand texture black 9969.855
88 x 32 x 42 RAL 7035 light grey 9969.856
88 x 32 x 42 Sand texture black 9969.857
88 x 24 x 48 RAL 7035 light grey 9969.912
48" 88 x 24 x 48 Sand texture black 9969.913
88 x 32 x 48 RAL 7035 light grey 9969.914
88 x 32 x 48 Sand texture black 9969.915
SplitRearDoors,WithoutSidewalls
BlackcellsindicateRittalXpressproduct.
RimatriX5 IT Solutions 15
Enclosures
Server Rittal TS8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Specifications
Frame System – Multi-Fold Frame Design:
•Steelframe–strengthandrigidity
•Torsionfreestructure
•Multipleinternalsurfacesandpointsformounting
•Maximuminternalvolumeforfootprint
•Externalaccesstoallinstallationpointsfordoors,
walls and baying
•Maximumloadbearingcapacity–3200lbs
(1451.5 kg)
ExternalSurfaces–DoorsandWalls:
•Securetoexternalsurfacesofframe
•Doorscanbeeasilyremovedorreversed
•Sidewallscanbescrewedon,lockedinplaceor
hinged to provide side door access
•Internaldoorhingeandlockpointsformaximum
security
•Doorstiffenertostabilizedoorandprovide
additional mounting surfaces
•Groundstudsonallsurfaces
•Externalsurfacesdonotaffectloadbearing
capacity – same ratings with or without panels
•AvailableinRAL7035lightgreyorRAL9005black
•Partiallyventedfrontviewdoor,fullyperforated
split-rear door
Vertical Mounting Rails:
•Fullydepthadjustablemaintainsloadcapacity
regardless of where the rails are positioned
•Floatinginstallationsystem–verticalrailsarenot
secured to frame members or lateral support
channels; can be adjusted independently
•“Z”shaped,multi-foldprofile–highloadbearing
capacity and multiple mounting surfaces
•19"mountingcapacityin24"cabinets,19"or23"
mounting capacity in 32" cabinets
•Umarkingsoninsideandoutsidesurfacesof
each rail
•Uniqueraildesignallowsforupto32Uinthe
zero"U"space
Key Accessories:
•Sidewalls
•DoorMountServerFanPanel
•BayingKits
•ToollessShelves–19"(482.6mm)Rackmount
•Casters
•CableManagementHardware–DRings,
VelcroStraps,MountingPlates,Manage-IT
•PowerStrips–15,20,30Amp;Verticalor
Rackmount
•CMC-TC–EnclosureMonitoringSystem
•BoltDownKits
•ToollessBlankingPanels
Innovative Design and
Enhanced Stability
Rittal's TS8 network enclosure – Ideal for showcase
applications, this enclosure features natural ventilation
with its perimeter perforated doors.
Design:
The TS8 network enclosure features a stylish design
in a viewing door concept that is clearly part of the
same family as the server enclosure.
Applications:
•Networkingfacilities
•Terminationapplications
•Hubs,routers,switchesorothercomponents
•Otherequipmentwherehighheatloads
are not generated
Environments:
•Datacenters
•MDC/IDC
•Wiringclosets
•Officeenvironments
•Centraloffices
•Co-locationandapplicationenvironments
Features:
•Contemporaryappearance
•Multiplevendorequipment
•Fulllineofaccessories
•Familyofsizesandstyles
•Goodheatdissipation
•Strongframestructure
•Viewingdoorversionoftheserverenclosure
that is value priced
NEMA 12 Networking
TS8 Enclosure
Networking TS8 Enclosure
Enclosures
Networking Rittal TS8
16 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
VentedViewingDoor,VentedSplitRearDoors,WithoutSidewalls
Rack Quick Reference  DimensionsHxWxD
Units (Depth) (inches) Color PartNo.
with viewing door
24" 48 x 24 x 24 RAL 7035 light grey 9969.874
48 x 24 x 24 Sand texture black 9969.875
48 x 24 x 32 RAL 7035 light grey 9969.858
24U 32" 48 x 24 x 32 Sand texture black 9969.859
48 x 32 x 32 RAL 7035 light grey 9969.860
48 x 32 x 32 Sand texture black 9969.861
80 x 24 x 32 RAL 7035 light grey 9969.862
42U 32" 80 x 24 x 32 Sand texture black 9969.863
80 x 32 x 32 RAL 7035 light grey 9969.864
80 x 32 x 32 Sand texture black 9969.865
88 x 24 x 32 RAL 7035 light grey 9969.866
47U 32" 88 x 24 x 32 Sand texture black 9969.867
88 x 32 x 32 RAL 7035 light grey 9969.868
88 x 32 x 32 Sand texture black 9969.869
NEMA 12, Viewing Door, Solid Rear Door, Without Sidewalls
Rack Quick Reference  DimensionsHxWxD
Units (Depth) (inches) Color PartNo.
with viewing door
48 x 24 x 24 RAL 7035 light grey 9969.876
24" 48 x 24 x 24 Sand texture black 9969.877
24U 48 x 24 x 32 RAL 7035 light grey 9969.884
48 x 24 x 32 Sand texture black 9969.885
32" 48 x 32 x 32 RAL 7035 light grey 9969.886
48 x 32 x 32 Sand texture black 9969.887
72 x 24 x 24 RAL 7035 light grey 9969.878
24" 72 x 24 x 24 Sand texture black 9969.879
38U 72 x 24 x 32 RAL 7035 light grey 9969.888
72 x 24 x 32 Sand texture black 9969.889
32" 72 x 32 x 32 RAL 7035 light grey 9969.890
72 x 32 x 32 Sand texture black 9969.891
80 x 24 x 24 RAL 7035 light grey 9969.880
24" 80 x 24 x 24 Sand texture black 9969.881
42U 80 x 24 x 32 RAL 7035 light grey 9969.892
80 x 24 x 32 Sand texture black 9969.893
32" 80 x 32 x 32 RAL 7035 light grey 9969.894
80 x 32 x 32 Sand texture black 9969.895
88 x 24 x 24 RAL 7035 light grey 9969.882
24" 88 x 24 x 24 Sand texture black 9969.883
47U 88 x 24 x 32 RAL 7035 light grey 9969.896
88 x 24 x 32 Sand texture black 9969.897
32" 88 x 32 x 32 RAL 7035 light grey 9969.898
88 x 32 x 32 Sand texture black 9969.899
Accessories Page
Sidewalls 38
Casters 41
Fans 58
Cable Management 33-36
 BlankingPanels 40
Shelves 48-51
Baying Kit 46
Bolt Down Kits 40
RimatriX5 IT Solutions 17
Enclosures
Networking Rittal TS8
BlackcellsindicateRittalXpressproduct.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
LCP Ready Cabinet
 Rack QuickReference DimensionsHxWxD Color PartNo.
Units (Depth) (inches)
40" 80 x 24 x 40 RAL 7035 light grey 9971.034
80 x 32 x 40 RAL 7035 light grey 9971.036
42U 48" 80 x 24 x 48 RAL 7035 light grey 9971.035
80 x 32 x 48 RAL 7035 light grey 9971.037
LCP Ready Cabinet
LCPreadycabinetforusewithLiquidCooling
Productline.Itisconfiguredwithairbrushbaffles
to funnel cooled air over mounted components.
•Glandplates
•Solidviewingfrontdoor
•Solidreardoor
•Solidroofwithcablepassesandgrommets
to cover up
•Airbrushbaffles
•MadeoutofTS8frame
Design:
The TS8 server enclosure features a stylish design
in a viewing door concept that is clearly part of the
same family as the server enclosure.
Applications:
•Universalserverenclosures
•Multiplevendorenvironments
•Storageequipment
•Terminationequipment
•Networkequipment
Environments:
•Datacenters
•MDC/IDC
•Wiringclosets
•Officeenvironments
•Centraloffices
•Co-locationandapplicationenvironments
Specifications
Frame System – Multi-Fold Frame Design:
•Steelframe–strengthandrigidity
•Torsionfreestructure
•Multipleinternalsurfacesandpointsformounting
•Maximuminternalvolumeforfootprint
•Externalaccesstoallinstallationpointsfordoors,
walls and baying
•Maximumloadbearingcapacity–3200lbs
(1451.5 kg)
ExternalSurfaces–DoorsandWalls:
•Securetoexternalsurfacesofframe
•Doorscanbeeasilyremovedorreversed
•Sidewallscanbescrewedon,lockedinplaceor
hinged to provide side door access
•Internaldoorhingeandlockpointsformaximum
security
•Doorstiffenertostabilizedoorandprovide
additional mounting surfaces
•Groundstudsonallsurfaces
•Externalsurfacesdonotaffectloadbearing
capacity – same ratings with or without panels
•AvailableinRAL7035lightgrey
Vertical Mounting Rails:
•Fullydepthadjustablemaintainsloadcapacity
regardless of where the rails are positioned
•Floatinginstallationsystem–verticalrailsarenot
secured to frame members or lateral support
channels; can be adjusted independently
•“Z”shaped,multi-foldprofile–highloadbearing
capacity and multiple mounting surfaces
•19"mountingcapacityin24"cabinets,19"or23"
mounting capacity in 32" cabinets
•Umarkingsoninsideandoutsidesurfacesof
each rail
•Uniqueraildesignallowsforupto32Uinthe
zero"U"space
Key Accessories:
•Sidewalls
•BayingKits
•ToollessShelves–19"(482.6mm)Rackmount
•CableManagementHardware–DRings,
VelcroStraps,MountingPlates,Manage-IT
•PowerStrips–15,20,30Amp;Verticalor
Rackmount
•CMC-TC–EnclosureMonitoringSystem
•BoltDownKits
•ToollessBlankingPanels
•Chillers
Enclosures
LCP Enclosures Server Enclosures
Features:
•Contemporaryappearance
•Multiplevendorequipment
•Fulllineofaccessories
•Familyofsizesandstyles
•Goodheatdissipation
•Strongframestructure
•Viewingdoorversionof
the server enclosure that
is value priced
18 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Simple,Fastand
Cost-Effective
Features:
•Matchingpremiumaccessories
for rapid installation in the
delivered state
•Noframestructure,optimum
accessibility
•Simpleremovalandinstallation
of doors and side panels
•Loadcapacityupto880lbs
(400 kg) for the network
enclosure and 1400 lbs (635 kg)
for the server enclosure
•Systemroofforcableentryand
active ventilation
Material:
Sheet steel
Surface Finish:
Mounting frame:
Electrophoretic dipcoat primed,
RAL 7044/RAL 7035 light grey
Enclosure panels:
Powdercoated,
RAL 7035 light grey
RAL 9005 black
to predetermined standard dimensions or complete
depth adjustability of the two 19" (482.6 mm) frames.
Because it comes prepared, installation proceeds
quickly. You will be amazed at what can be achieved
in a short period of time.
There is also a matching range of accessories and
system components for power supply, climate control
and security. Concepts are tailored precisely to your
requirements. Data protection and availability are an
absolute must!
TheRittalTE7000isgearedtoward“network”tasks
andisreadytouse.This“enclosurewithoutaframe”
is perfect for quick, cost-effective cabling. Cut your
costs without compromising protection.
The Rittal TE 7000 specializes in cutting time and
costs. Two 19" (482.6 mm) attachment levels in the
19" (482.6 mm) multi-functional profile create a solid
framework. Load capacity is 880 lbs (400 kg) for
the network enclosure and 1400 lbs (635 kg) for the
server enclosure.
The benefits include optimum accessibility, maximum
use of the interior space and super-fast assembly.
The dimensions and attachment points are tailored
TE 7000 Server Enclosures
Rack Quick Reference DimensionsHxWxD
Units
(Depth) (inches) Color PartNo.
w/o sidewalls, including baying kit
80 x 24 x 40 RAL 7035 light grey 7000.882
42U 40" 80 x 24 x 40 RAL 9005 black 7000.885
80 x 32 x 40 RAL 7035 light grey 7000.892
80 x 32 x 40 RAL 9005 black 7000.895
TE 7000 Network Enclosures
Rack Quick Reference DimensionsHxWxD
Color PartNo.
Units (Depth) (inches)
with sidewalls
11U 24" 24 x 24 x 24 RAL 7035 light grey 7000.390
32" 24 x 24 x 32 RAL 7035 light grey 7000.410
24" 48 x 24 x 24 RAL 7035 light grey 7000.430
24U 48 x 32 x 24 RAL 7035 light grey 7000.450
32" 48 x 24 x 32 RAL 7035 light grey 7000.440
48 x 32 x 32 RAL 7035 light grey 7000.460
24" 80 x 24 x 24 RAL 7035 light grey 7000.500
80 x 24 x 24 RAL 9005 black 7000.505
32" 80 x 24 x 32 RAL 7035 light grey 7000.510
42U 80 x 24 x 32 RAL 9005 black 7000.515
24" 80 x 32 x 24 RAL 7035 light grey 7000.520
80 x 32 x 24 RAL 9005 black 7000.525
32" 80 x 32 x 32 RAL 7035 light grey 7000.530
80 x 32 x 32 RAL 9005 black 7000.535
24" 88 x 24 x 24 RAL 7035 light grey 7000.560
47U 88 x 24 x 32 RAL 7035 light grey 7000.570
32" 88 x 32 x 24 RAL 7035 light grey 7000.580
88 x 32 x 32 RAL 7035 light grey 7000.590
Quick Reference DimensionsHxWxD
(Depth) (inches) Color PartNo.
w/o sidewalls, including baying kit
42U 24" 80 x 24 x 24 RAL 7035 light grey 7000.502
32" 80 x 32 x 32 RAL 7035 light grey 7000.532
47U 24" 88 x 24 x 24 RAL 7035 light grey 7000.562
32" 88 x 32 x 32 RAL 7035 light grey 7000.592
Accessories Page
Sidewalls 38
Casters 41
Fans 58
Cable Management 33-36
 BlankingPanels 40
Shelves 48-51
Baying Kit 46
Bolt Down Kits 40
RimatriX5 IT Solutions 19
Enclosures
Networking RittalTE7000,TopEfficiency:TheGlobalITEnclosure
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Quick Assembly
intheDepth
Ready to Install –
with the Standard
Spacing19.49"(495mm)
The premium accessories are
tailored to this fixed dimension
when delivered for all enclosure
formats. All installed equipment for
the enclosure depth is mounted
easily, quickly and precisely to
the TS8 system holes. This is
equivalent to the standard dimen-
sion of 15.74" (400 mm) deep TS
enclosure’s inner level.
Adjustable–ona1.97"
(50 mm) Pitch Pattern
The distance between the two
19" (482.6 mm) frames may
be altered in increments of 1.97"
(50 mm) or 17.52 – 27.36" (445
695 mm). Quick replacement of the
principal components is offered in
the table below.
Adjustable – Fully Individual
The distance between frames
may be selected freely via the slot
fastening. All key mounting
components – punched sections
with mounting flanges, installation
kits, slide rails, component
shelves – are also available in
depth-adjustable format.
Explanationoflevels
19.49" (495 mm) – the distance
between the two 19" (482.6 mm)
frames in the delivered state
for all enclosure formats.
Pitchspacing1.97"(50mm)
Distance from door:
2.07" (52.5 mm) with depth
23.62" (600 mm), 6" (152.5 mm)
with depth 31.50" (800 mm)
The attachment distance
within a mounting frame at the
rear horizontal, is equivalent
to the frame attachment
dimension of a 23.62" (600 mm)
wide TS8 (outer level, 20.67"
[525 mm])
➎ = 4.72" (120 mm)
Quick Assembly
in the Width
All components for the TS8
enclosure dimension W/D 23.62"
(600 mm) (outer level) fit into the
width of the TE frame sections.
Three rows of TS8 system holes
offer suitable solutions for every
task. The installation position in the
enclosure depth corresponds to
the TS8 inner level.
Example
23.62 x 23.62" (600 x 600 mm)
Example
31.49 x 31.49" (800 x 800 mm)
600
600
600
800
800
600
800
800
1
11
1111
1
 QuickReplacement  Page
Enclosure depth, inches (mm) 23.64 (600)
31.49 (800)
 Possibledistancesbetweenthe19"(482.6mm)levels 17.52 (445) 19.49 (495) 21.46 (545) 23.43 (595) 25.39 (645) 27.36 (695)
Slide rail for TE, for attachment between the 19" (482.6 mm) 7963.410 7963.510 7963.610 27
mounting frames, fixed length
19"(482.6mm)component shelf for static installation,
for direct screw fastening without installation kit, 7000.620 48
16.14" (410 mm) deep, load capacity 66 lbs (30 kg), static
19"(482.6mm)componentshelf for static installation, 110 lbs
(50 kg), 18.54" (471 mm) wide, in conjunction with punched 7164.035 7164.035 7165.035 7165.035 7166.035 7166.035 *
section with mounting flange, max. base depth
Punched section with mounting flange .66 x 2.87" (17 x 73 mm),
for mounting components, attachment in the enclosure depth 8612.140 8612.040 8612.150 8612.050 8612.160 8612.060 44
between the 19" (482.6 mm) mounting frames
C rail for cable clamping in the enclosure depth via cable clamps 7828.040 7828.040 7828.050 7828.050 7828.060 7828.060 *
Cableclamprails, depth variable 16.73 – 28.54" (425 – 725 mm), 7858.160 7858.160 7858.160 7858.160 7858.160 7858.160 *
for cable attachment in the enclosure depth via cable ties
* See Handbook 31
BluecellsindicateAitems.
20 RimatriX5 IT Solutions
Enclosures
Networking RittalTE7000,TopEfficiency:TheGlobalITEnclosure
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
TS8 Co-Location Enclosures
This server enclosure has been specifically engineered
for the co-location/web hosting market and is offered
in versions with 2 and 4 bays. These multi-
compartment enclosures are designed with fully
perforated doors front and rear for maximum heat
dissipation, 19" (482.6 mm) server rails front and rear,
in addition to separate, fully secured cable troughs in
each compartment for data and power cabling. The
enclosure offers the ability to bring in power and
data cabling from the top or from the bottom.
Specifications:
•42Uand47U
•Fullyperforatedfrontandreardoors
•Comforthandlewithlockinsert
•Standardproductkeyedalike,uniqueinserts
available
•Cableentryroofwith4roundcableentryholes
•“L”shapedserverrails,frontandrear,infinite
depth adjustment
•Partitionwallinstalled
•Separatesecureroutingsfordataandpowercables
to each compartment
•Fullwidthanddepthdividerplatesinstalled
between sections
Note: Enclosure does not come with additional
captive nuts and screws
For more information contact Rittal.
Split Front Door 4 Compartments
Enclosures
SpecialtyEnclosures Rittal TS8 Co-Location
RimatriX5 IT Solutions 21
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Viewing Door Series
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
6U 24" 14 x 24 x 24 RAL 7035 light grey 7502.016
9U 24" 20 x 24 x 24 RAL 7035 light grey 7502.026
12U 24" 25 x 24 x 24 RAL 7035 light grey 7502.036
15U 24" 30 x 24 x 24 RAL 7035 light grey 7502.046
18U 24" 35 x 24 x 24 RAL 7035 light grey 7502.056
21U 24" 41 x 24 x 24 RAL 7035 light grey 7502.066
Solid Sheet Steel Door Series
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
9U 24" 20 x 24 x 24 RAL 7035 light grey 7502.126
12U 24" 25 x 24 x 24 RAL 7035 light grey 7502.136
15U 24" 30 x 24 x 24 RAL 7035 light grey 7502.146
21U 24" 41 x 24 x 24 7502.166
Your answer for small networks or
floor distributors, in data rooms,
office space or school facilities.
Rittal’s QuickBox wallmount
enclosures combine variety with
flexibility and cost efficiency. With
its depth-adjustable 19" (482.6 mm)
mounting rails, the QuickBox is
the ideal solution for packaging
network equipment or floor
distributors. One enclosure,
12 models – that means 12
standard products instead of
complicated custom fabrication.
Choose from a large selection
of sizes, with or without viewing
door, that offer cost-efficient,
customer-oriented solutions for
the most diverse applications.
The QuickBox is available off-
the-shelf, completely assembled.
In every respect the QuickBox is
the optimum combination of the
proven quality and flexibility of
Rittal enclosures.
Applications:
A smart solution for small networks or floor distributors,
based on customers’ needs. One of its outstanding
features is the easy and unobstructed access to all
components and wiring. QuickBox offers a complete
solution ideal for educational applications.
•Terminationequipment
•Networkingequipment
Environments:
•Dataroomsandofficespaces
•Passiveequipment
•Schoolfacilities
Features:
•Cost-efficientandsecure
•Oneenclosure,12models
•Off-the-shelf,completelyassembled
•Versatile2-partdesign
Specifications:
•Wallmountsectionwith19"(482.6mm)rails
and brush inserts
•Housingcoverwithbase
•Coverwithventslotsandbrushinserts
•Sheetsteelorviewingdooroptions
•Securitylocksonfrontdoorandtwosides
•Cablecollectingcombinationrails
•Front19"(482.6mm)rails,infinitelydepthadjustable
•RAL7035lightgrey
Design:
Wallmount panel for 19" (482.6 mm) components.
Cover has vent slots for ventilation through convec-
tion,andisabletosupportfansaswell.Viewingdoor
or sheet steel door with lock for access from front.
Cable entry panels with brush insert and integrated
cable collecting rail. The removable cover makes
installation extremely easy.
Customers:
•Contractorsandinstallers
•Educationalenvironments
•Governmentinstitutions
24"
24"
RAL 7035
light grey
RAL 7035
light grey
Enclosures
Wallmount Enclosures QuickBox Enclosures
22 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Specifications:
•Rearhousingwithremovabletopandbottomcovers
•Twoverticalsystembars
•Cablecollectingrail
•Centerswingframewithlockandtwoadjustable
19" (482.6 mm) rails
•Frontviewingdoorwithlockingminicomforthandle
•RAL7035lightgreyand7015slategrey
•NEMA12protection
Design:
Wallmountable design with built-in swing frame
for access to rear equipment. Secure and sturdy
withNEMA12protectionavailable.Roll-formed
construction provides high stability and component
protection.
Customers:
•Educationalapplications
•Officebuildingsandhospitals
•Smallclustersofworkstations
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
6U 19" 14 x 24 x 19 RAL 7035/7015 7706.135
9U 19" 19 x 24 x 19 RAL 7035/7015 7709.135
12U 19" 24 x 24 x 19 RAL 7035/7015 7712.135
15U 19" 29 x 24 x 19 RAL 7035/7015 7715.135
18U 19" 35 x 24 x 19 RAL 7035/7015 7718.135
21U 19" 40 x 24 x 19 RAL 7035/7015 7721.135
 Rack QuickReference DimensionsHxWxD Color PartNo.
Units (Depth) (inches)
12U 24" 24 x 24 x 24 RAL 7035/7015 9969.580
15U 24" 29 x 24 x 24 RAL 7035/7015 9969.581
21U 24" 40 x 24 x 24 RAL 7035/7015 9969.582
An ideal solution for simple
wallmount installations while
assuring only authorized entry.
Rittal’s wallmount network enclo-
sures offer stability, accessibility
and security to the networking
specialist. All standard models
feature usable panel heights from
6Uto21U,ensuresafepackaging
for sensitive components as well
as protection from the environment
and from unauthorized access.
Double security is assured
through separate locks on the
center swing frame section and
the front viewing door. Rittal’s
3-part wallmount enclosures – a
perfect combination of protection
and versatility.
Applications:
Ideal for small networks or floor distribution in
environments that require a high degree of security
and a high industrial protection rating.
•Activecomponents
•Networkingandmonitoringequipment
•Terminationequipment
Environments:
•NEMA12environments
•Smallernetworks
•Remotemodels
•Climateconsideration
•Officesorfactoryenvironments
Features:
•Wallmountabledesign
•NEMA12protection
•Widerangeofaccessories
•Built-inswingframe
•Secureandsturdy
•Safetyglass
19"
24"
RAL 7035 light grey/
7015 slate grey
RAL 7035 light grey/
7015 slate grey
RimatriX5 IT Solutions 23
Enclosures
Wallmount Enclosures ELNEMA123-PartEnclosures
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BluecellsindicateAitems.
Enclosures
Specifications:
•Rearhousingwithremovabletopandbottomcovers
•Twoverticalsystembars
•Cablecollectingrail
•Centerswingframewithlockandtwoadjustable
19" (482.6 mm) rails
•Frontviewingdoorwithlockingminicomforthandle
•Twofilters
•Groundbus
•RAL7035lightgreyandRAL7015slategrey
Design:
Wallmount section with cable entry gland panels.
Hinged swing-out center section for easy access
to components and wiring. Depth-variable 19"
(482.6 mm) mounting surface.
Material:
Wall and hinged part:
Sheet steel, .06" (1.5 mm)
Viewingwindow:
0.12" (3 mm) safety glass
Features:
•Separate,swing-outcentersectionforfrontandrear
component access
•Widerangeofaccessories
•Sturdydesignprovidessolidsupportforequipment
Protection Category:
Max.IP43toEN60529/10.91whenusingsolid
gland plates.
Applications:
This wallmount is ideal for small networks or floor
distribution in environments that require a high degree
of security.
•Activecomponents
•Networkingandmonitoringequipment
•Terminationequipment
Environments:
•Offices,schools,andhospitals
•Factoryfloorapplications
Customers:
•Educationalapplications
•Officebuildingsandhospitals
•Smallclustersofworkstations
SupplyIncludes:
Wall section:
With vertical punched rails and C rail mounted
horizontally for cable clamping, top cable gland
plate solid, bottom cable gland plate with brush
strips, earthing rail with star earthing, wall mounting
bracket 10 mm.
Hinged part:
With 0.98" (25 mm) pitch pattern of holes in the front
and rear frame, two 19" (482.6 mm) mounting angles
mounted on C rails, infinitely depth-variable, one
outlet filter each on the left and right side.
Designer glazed door:
With 3 mm single-pane safety glass window,
9+15Uwithminicomforthandleforlockinserts,
21Uwithcomforthandleand2-pointlocking,
including lock 3524 E.
Rack Units Quick Reference
(Depth)
DimensionsHxWxD
(inches) Color LoadCapacity
(lbs) PartNo.
9U
23"
24 x 24 x 23
RAL 7035/
Slate grey 7015
99 7709.735
15U 29 x 24 x 23 165 7715.735
21U 40 x 24 x 23 165 7721.735
9U
27"
24 x 19 x 27 99 7709.535
15U 24 x 30 x 27 165 7715.535
21U 24 x 40 x 27 165 7721.535
Rittal’s wallmount network enclo-
sures offer stability, accessibility
and security to the networking
specialist. All standard models
feature usable panel heights from
9Uto21U,ensuresafepackaging
for sensitive components as well
as protection from the environment
and from unauthorized access.
Double security is assured
through separate locks on the
center swing frame section and
the front viewing door.
Enclosures
Wallmount Enclosures ELNon-NEMA3-PartEnclosures
24 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
FanExpansionKit
 Voltage Packsof PartNo.
 230Vfan 1set 7980.000
 115Vfan 1set 7980.110
Wallmounting Brackets
 Stand-offdimensionA Packsof PartNo.
1.58" (40 mm) 4 2503.200
0.39" (10 mm) 4 2508.200
ReplacementExhaustFilters
 Packsof PartNo.
5 filters 3322.700
Cable Entry Panel with Brush Insert
Color PartNo.
RAL 7035 light grey 7705.035
FanExpansionKits
For retrofitting various fan units or to supplement the
fan mounting plate and modular fan roof.
TechnicalSpecifications:
Ratedvoltage:115or230V
Rated current: 19/18 W for 50/60 Hz
Air displacement (unimpeded airflow):
85/100 cfm/ for 50/60 Hz
Temperature range:
14°F to 131°F (-10°C to +55°C)
Wallmounting Brackets
Utilizepre-drilledholesinrearwall.Versionwith
1.58" (40 mm) stand-off allows cable routing behind
the enclosure.
Material:
Steel, chromated
Cable Entry Panel with
Brush Insert
Multi-folded and welded, with foamed-on gasket and
plastic brush insert for easy cable entry.
ReplacementExhaustFilters:
These filters replace standard equipment mounted
on the right and left sidewalls of center section.
C Rails
To accommodate large tensile forces, larger cables
or cable sections via cable clamps, and for tidy cable
routing inside the enclosure.
The cable clamp rails may be located directly on
a 19" (482.6 mm) mounting frame, horizontally at
the rear or in the enclosure depth between two
mounting frames. An additional screw fastening
secures the unit.
If the rail is to be secured between two mounting
frames, it is necessary to secure the two 19" (482.6 mm)
mounting frames at the corresponding distance from
one another beforehand.
Slide Rails
For mounting between a front and a rear pair of
mounting angles. The slide rail can be used to
support heavy slide-in equipment.
H x W: 3.15 x 3.35" (80 x 85 mm)
LoadCapacity:
176 lbs (80 kg)
Material:
Sheet Steel, zinc-plated, passivated
For center part Packsof PartNo.
depth
8.50" (216 mm) 4 2238.000
12.44" (316 mm) 4 2239.000
16.38" (416 mm) 4 2237.000
For center part Packsof PartNo.
depth
8.50" (216 mm) 10 2240.000
12.44" (316 mm) 10 2250.000
16.38" (416 mm) 10 2260.000
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
4 C rails, including assembly parts
Accessories:
Cable clamps
SupplyIncludes:
2 slide rails, assembly parts
Possible Alternatives:
Depth-adjustable slide rails
RimatriX5 IT Solutions 25
Enclosures
Wallmount Enclosures ELNon-NEMA3-PartAccessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Features:
•One-piece19"(482.6mm)wallmountedenclosure,
rigidly constructed
•Withglazedorsheetsteeldooratthefront,including
security lock 3524 E
•Interchangeabledoorhinge
•Openrearpanelprovidesspaceforcableentry
•19"(482.6mm)mountinganglesatthefront,from
inner edge of door adjustable in the depth from
0.98 to 4.33" (25 to 110 mm)
•Roundopeningsonallsidesforcableentry
between several enclosures, or for access during
installation and maintenance work, concealed
by covers
•Threerectangularholesatthereartopandbottom,
optionally for cable entry
•Ventslotsatthesideforpassiveventilation
Material:
Sheet steel enclosure, viewing window, single-pane
safety glass 0.12" (3 mm)
Surface Finish:
Primed,powdercoated
Color:
RAL 7035 light grey
SupplyIncludes:
Wallmounted enclosure with 19" (482.6 mm) rails
at the front
Innovative and Cost-Effective
Packaging Solution
GlazedDoorwith0.12"(3mm)SafetyGlass
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
 6U 19" 14x24x19 RAL7035lightgrey 7000.700
 9U 19" 19x24x19 RAL7035lightgrey 7000.710
 12U 19" 24x24x19 RAL7035lightgrey 7000.720
 15U 19" 29x24x19 RAL7035lightgrey 7000.730
Sheet Steel Door, Solid
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
 6U 19" 14x24x19 RAL7035lightgrey 7000.750
 9U 19" 19x24x19 RAL7035lightgrey 7000.760
 12U 19" 24x24x19 RAL7035lightgrey 7000.770
 15U 19" 29x24x19 RAL7035lightgrey 7000.780
19"
19"
RAL 7035 light grey
RAL 7035 light grey
26 RimatriX5 IT Solutions
Enclosures
Wallmount Enclosures TE Wallbox
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
The innovative concept behind the FlatBox unites optimized
storage and shipping costs with cleverly designed, toolless,
fast one-person assembly. As you would expect, Rittal prides
itself on details. Compatible with the extensive range
of existing system accessories, and can be used as a
wallmountedoroor-standingenclosure.Unrestricted
accessibility during installation of the network components.
The width and depth dimension of 27.56" (700 mm)
provides plenty of space for use as a patch distributor,
and small networks with active technology are also ideal
for climate control via the fan panels (maximum of 8).
Pre-assemblethebaseframe,locateintothe
attachment points on the wall, and secure. Configuration of the open enclosure is now
possible. Slide the roof and gland plates into
position, insert the side panels, locate and lock
the door, and it’s done!
If the FlatBox is used as a floor-standing
enclosure, leveling feet are fastened to
the gland plate.
The leveling feet allow the FlatBox to be used
as a desktop enclosure, e.g., in measurement
and control technology, or as an underdesk
enclosure in the form of a small network node.
Optimumcableentry via brush strips top
and bottom, plus plenty of space for cable
distribution in the enclosure depth. Even active
components with pre-assembled connectors
may be routed.
The snap connection system facilitates toolless
enclosure assembly. Once clipped into place,
a very stable enclosure is created with a high
staticloadcapacityof11lb(5kg)/Uora
maximum of 165 lb (75 kg).
RimatriX5 IT Solutions 27
Enclosures
Wallmount FlatBox Features
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Material:
Sheet steel
Surface Finish:
Powder-coatedinRAL7035
light grey
SupplyIncludes:
Flat-packed enclosure,
1 wall section, 2 basic supports, 2
roof/gland plates, with cut-outs for
cable entry, with brush strips, 2
19" (482.6 mm) mounting
angles(for6Uand9U),
1 19" (482.6 mm) mounting
frame(from12U),
4levelingfeet(from12U),
2 side panels, lockable,
1 glazed door, lockable,
door hinge point selectable.
Earth straps for earthing of
panels.
Components for toolless, fast
assembly.
With19"(482.6mm)mountingframeatthefront
and glazed door Packsof
U 12 15 12 15 18 21
Width (B) inches (mm) 23.62 (600) 23.62 (600) 23.62 (600) 27.56 (700) 27.56 (700) 27.56 (700)
Height (H) inches (mm) 24.61 (625) 29.84 (758) 24.61 (625) 29.84 (758) 35.12 (892) 40.35 (1025)
Depth(T)inches(mm) 15.75 (400) 15.75 (400) 23.62 (600) 27.56 (700) 27.56 (700) 27.56 (700)
PartNo. 17507.020 7507.030 7507.120 7507.2001) 7507.2101) 7507.2201)
Accessories
19"mountinganglesas2ndattachmentlevel,12U 2 7507.712 7507.712
19"mountinganglesas2ndattachmentlevel,15U 2 7507.715 7507.715
19"mountinganglesas2ndattachmentlevel,18U 2 7507.718
19"mountinganglesas2ndattachmentlevel,21U 2 7507.721
Cover plates for fan panels 6 7507.760 7507.76 7507.76 7507.76 7507.76 7507.76
Earth rail 1 7113.000 7113.000 7113.000 7113.000 7113.000 7113.000
C rail for cable clamping 1 7016.140 7016.140 7016.140 7016.140 7016.140 7016.140
T-head rail for cable clamping 1 7016.150 7016.150 7016.150 7016.150 7016.150 7016.150
Fan,230VAC,50/60Hz,69/80cfm(117/135m3/h), air
throughput, unimpeded airflow 1 7980.100 7980.100 7980.100 7980.100 7980.100 7980.100
Fan,48VDC,108cfm(184m3/h), air throughput,
unimpeded airflow 1 7980.148 7980.148 7980.148 7980.148 7980.148 7980.148
Thermostat 1 3110.000 3110.000 3110.000 3110.000 3110.000 3110.000
1)Pre-configuredvariantavailableonrequest.
With19"(482.6mm)mountinganglesatthefront
and glazed door Packsof
U 6 9 6 9
Width (B) inches (mm) 23.62 (600) 23.62 (600) 23.62 (600) 23.62 (600)
Height (H) inches (mm) 14.09 (358) 19.37 (492) 14.09 (358) 19.37 (492)
Depth(T)inches(mm) 15.75 (400) 15.75 (400) 23.62 (600) 23.62 (600)
PartNo. 17507.000 7507.010 7507.100 7507.110
Accessories
19"mountinganglesas2ndattachmentlevel,6U 2 7507.706 7507.706
19"mountinganglesas2ndattachmentlevel,9U 2 – 7507.709 – 7507.709
Levelling feet 4 7507.740 7507.740 7507.740 7507.740
Cover plates for fan panels 6 7507.760 7507.76 7507.76 7507.760
Earth rail 1 7113.000 7113.000 7113.000 7113.000
C rail for cable clamping 1 7016.140 7016.140 7016.140 7016.140
T-head rail for cable clamping 1 7016.150 7016.150 7016.150 7016.150
Fan,230VAC,50/60Hz,69/90cfm(117/135m3/h), air
throughput, unimpeded airflow 1 7980.100 7980.100 7980.100 7980.100
Fan,48VDC,108cfm(184m3/h), air throughput, unimpeded
airflow 1 7980.148 7980.148 7980.148 7980.148
Thermostat 1 3110.000 3110.000 3110.000 3110.000
T
B
H
BlackcellsindicateRittalXpressproduct.
28 RimatriX5 IT Solutions
Enclosures
Wallmount Flatbox
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Cover Plates for Fan Panels
To cover unused fan panels when using fans
in the FlatBox.
Material:
Sheet steel
Surface Finish:
Powder-coatedinRAL7035lightgrey
SupplyIncludes:
Assembly parts
 Packsof PartNo.
6 7507.760
RimatriX5 IT Solutions 29
Enclosures
Wallmount Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safe Housing
Where You Need It Most
Mobile or stationary, your monitors, servers, keyboards,
printers and other network components can find safe
housing in these Rittal Data Racks. A second
19" (482.6 mm) mounting frame facilitates installation
of component shelves, slide rails, or cable manage-
ment solutions. Together the Rittal Data Rack, optional
second mounting frame and our comprehensive
accessory program offer smart solutions for a
multitude of network applications.
Specifications:
•19"(482.6mm)verticalframe
•Basewithintegratedfeet
•Captivenutsandscrewsorderedseparately
•RAL7035lightgreyframehighlightedwith
RAL 5018 teal trim
•Additional19"(482.6mm)mountingframeincludes
installation hardware
Design:
Its torsion resistant frame of 14 ga/2 mm is welded
together and has a high load capacity of 300 lbs
(136 kg) frame. The 6-fold, roll formed, vertical
frames are punched in front and back for mounting
19" (482.6 mm) components and have additional
installation holes on the sides.
Applications:
Open rack system for installation in distribution rooms,
for flexible networks and for laboratory
systems. Components installed on either one or two
mounting surfaces are accessible from all sides.
•Networkcomponents
•Activecomponents
•Passiveequipment
•MISapplications
•Other19"(482.6mm)rackmountapplications
Environments:
•IDFs
•Datarooms
•Offices
Features:
•Installationholesonbase,sidesandrear
•Easyportabilityandaccess
•Standaloneorbayedtogether
•Basecanbeboltedtofloorormountedontwin
wheel casters
•Secondmountingframeavailable
•Torsionfreeframe
Accessories Page
Casters 41
Cable Management 33-36
 BlankingPanels 40
Shelves 48-51
Baying Kit 46
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
31U 59 x 22 x 30 RAL 7035 light grey 7391.000
w/ RAL 5018 teal trim
36U
30"
68 x 22 x 30 RAL 7035 light grey 7396.000
w/ RAL 5018 teal trim
40U 75 x 22 x 30 RAL 7035 light grey 7400.000
w/ RAL 5018 teal trim
45U 84 x 22 x 30 RAL 7035 light grey 7445.000
w/ RAL 5018 teal trim
 Rack QuickReference DimensionsHxWxD Color PartNo.
 Units (Depth) (inches)
31U 59 x 22 x 30 RAL 7035 light grey 7296.000
w/ RAL 5018 teal trim
36U
30"
68 x 22 x 30 RAL 7035 light grey 7297.000
w/ RAL 5018 teal trim
40U 75 x 22 x 30 RAL 7035 light grey 7298.000
w/ RAL 5018 teal trim
45U 84 x 22 x 30 RAL 7035 light grey 7299.000
w/ RAL 5018 teal trim
RAL 7035 light grey
w/ RAL 5018 teal trim
RAL 7035 light grey
w/ RAL 5018 teal trim
Stand alone or bayed together
BluecellsindicateAitems.
BluecellsindicateAitems.
Additional Frame
Enclosures
Enclosures
Networking Data Racks
30 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
With your applications in mind, Rittal provides a wealth of system
accessories for infinite possibilities. We address your requirements
with superior expertise.
Take a closer look.
This is your opportunity to become faster and to offer a better solution.
Get Connected!
Cable Management
Manage-IT ............................................. 32
Cable Ties ............................................. 34
NylonLoopFasteners .................................... 34
CableGuideRings....................................... 34
Cable Routing Across 19" (482.6 mm)
Mounting Level.......................................... 35
19" (482.6 mm) Cable Troughs ............................. 35
19"(482.6mm)CableEntryPanels.......................... 35
Cable Management Rail................................... 36
System Lights
Enclosure Lights......................................... 37
Door Operating Switch.................................... 37
Roof/Base/Sidewall Configuration
Stabilizers for Server Enclosures ............................ 37
Sidewalls .............................................. 38
ModulePlates,Solid...................................... 39
ModulePlates,Solid,WithBrushStrips,
VentedCompensating
Configuration ........................................... 39
BlankingPanels ......................................... 40
Air Brush Baffles......................................... 40
Bolt Down Kits .......................................... 40
Transport Casters....................................... 41
Twin Casters............................................ 41
Caster Kit .............................................. 41
Leveling Feet ........................................... 41
Interior Installation
Slide Rails.............................................. 42
SlideRails,Depth–Variable,1U ............................ 42
TS System Chassis....................................... 43
TSSystemChassis,Depth-Variable ......................... 43
AdapterRailforPSCompatibility............................ 43
PSPunchedRails........................................ 44
MountingBracketPS ..................................... 44
Mounting Kit ............................................ 44
MountingPlates,Brackets ................................. 45
BayingComponents
Baying Kit .............................................. 46
Baying Connectors, External . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Baying Bracket.......................................... 46
Grounding
CompleteGroundingKits.................................. 47
Assembly Screws........................................ 47
Torx Screws, Self-Tapping Screws,
Drilling Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Shelves
Toolless Shelves ......................................... 48
Heavy-Duty Toolless Shelves ............................... 48
Component Shelf ........................................ 48
ComponentShelves,1/2U,
Depth-Variable .......................................... 49
Component Shelves,
2UStaticInstallation...................................... 49
ComponentShelf,2UStatic
Installation or Fully Extendable ............................. 49
Component Shelves, 19" (482.6 mm) Configuration ............. 50
Component Shelves, Without
19" (482.6 mm) Rail Mounting .............................. 50
Telescopic Slides for
Component Shelves ...................................... 50
Handle for Component Shelves ............................. 50
Hinged Cable Carriers .................................... 50
InstallationKits,Depth-Variable ............................. 50
Enclosures
RimatriX5 IT Solutions 31
Enclosures
System Accessories GetConnected–Accessorize
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Product Features:
•BendRadiicompliantperANSI/TIA/EIA,round
edges prevent performance degradation and
damaged cables
•Frontandrearcablemanagementcapabilitiesallow
separation of distribution cables and patch cords
•Easyassemblyreducesinstallationtime
•Modular9Usectionsallowforcustomconfigurations
•1UcableguidesaligntoenclosuresRUspacingfor
ease of installation and maintenance
•Coverandretainershingeleftorrightandcanbe
removed for easy access
•Passthroughportsforfront/rearcablerouting
Manage-IT
Cable Management System
for Rittal TS8 and TE 7000
Enclosures
Networkingenclosureshouse
more equipment now than ever
before. The ever-increasing
demand for reliable and efficient
data transmission requires the
highest level of uninterrupted
system performance possible.
Poorcablemanagementmay
lead to damaged cables,
performance degradation
and costly downtime.
Propercablemanagement
ensures optimum data transmission,
cost savings, and cable protection.
Rittal’s Manage-IT cable manager
is a simple, flexible and cost-
effective way to organize your
cables and patch cords.
•Integralcableretentionkeeps
cable bundles in place
•Accommodatesavarietyof
toolless cable management
accessories to further separate,
organize and protect cables
•Toollesscablemanagers
mount anywhere within the
vertical trough or enclosure
frame for unsurpassed cable
management options
Configuration:
•19"x2Uand1Uhorizontalenclosuremount
manager with pivoting/removable cover
•9Ux6"deepverticalmanagerkit.Availableinthree
widths (3.5, 7.5 and 10"). Includes cable retainers
•Largepathwaysforgreatercapacityandflexibility
when managing high-density patch cables
•ManagerfingersalignwithRMUspacingof
enclosures EIA rail
•Bendradiusonallcablepathwaysprovidesadded
support for copper and fiber data cables
•Accommodatesavarietyofcablemanager
accessories for additional options and
ultimate flexibility
Indicates its use with TS8 products Indicates its use with TE 7000 products
Enclosures
Enclosures
System Accessories Cable Management
32 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BlackcellsindicateRittalXpressproduct.
BlackcellsindicateRittalXpressproduct.
1
2
3
4
5
6
Indicates its use with TS8 products Indicates its use with TE 7000 products
Configuration:
Mounting bracket securely latches onto vertical EIA rail
Baseplate
Quarter-turn cable collection claw (accessory)
Pivoting/removablecableguides
Cable slack spool (accessory)
Quarter-turnVelcrocablefastener(accessory)
1
Manage-ITCableCapacity
Description Cable Diameter (sq. in.) PartNo.
0.15 0.17 0.19 0.21 0.23 0.25 0.27
15.75"(400mm)x3.5"(89mm)VerticalCableManager 466 363 290 238 198 168 144 9969.593
15.75"(400mm)x7.5"(190mm)VerticalCableManager 1166 908 727 595 496 420 360 9969.595
15.75"(400mm)x10"(254mm)VerticalCableManager 1166 908 727 595 496 420 360 9969.598
Horizontal2URackmountManagerwithCover 260 202 162 132 110 93 80 9969.597
Horizontal1URackmountManagerwithCover 127 98 79 64 54 45 39 9969.736
For Description PartNo.
TS
3.5"Widex9UVerticalManagerKitfor23.62"(600mm)SuitedEnclosuresand27.56-31.50"(700-800mm)StandAloneEnclosures 9969.593
3.5"Widex9UManagerCover 9969.594
7.5"Widex9UVerticalManagerKitfor27.56"(700mm)WideSuitedEnclosures 9969.595
7.5"Widex9UManagerCover 9969.596
10"Widex9UVerticalManagerKitfor31.50"(800mm)WideSuitedEnclosures 9969.598
2UEnclosureMountManagerwithHingeable/RemovableCover 9969.597
Quarter-turnVelcroCableFastener(Accessory) 9969.599
Quarter-turn Cable Collection Claw (Accessory) 9969.600
Cable Slack Spool with M5.5 Mounting Screw (Accessory) 9969.601
TE 3.5"Widex9UVerticalManagerfor31.50"(800mm)WideStandAloneEnclosures 9969.983
TE 7.5"Widex9UVerticalManagerfor31.50"(800mm)WideSuitedEnclosures 9969.984
TE
TS
Cable Trough, Front to Back 9969.929
Quarter-turn Cable Manager for 23.62" (600 mm) Suited Enclosures* 9969.928
Quarter-turn Cable Manager for 23.62" (600 mm) Stand Alone Cabinets* 9969.927
*ThisbracketisforusewiththeVelcroCableFastenerortheCableCollectionClaw
Manage-IT
Enclosures
RimatriX5 IT Solutions 33
Enclosures
System Accessories Cable Management
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BlackcellsindicateRittalXpressproduct.
BluecellsindicateAitems.
BluecellsindicateAitems.
Cable Ties
Cable ties, for quick assembly.
The super-fast solution for attaching cables to the
enclosure profile or to the rear of the 19" (482.6 mm)
mounting frame. Simply clip into the round system
punchings.
Overhead Cable Management
Providescablemanagementoutsidethecabinet
easy. Fastens to existing roof tool-lessly through use
of 2 snap rings and pre-existing cable passes on
cabinet roof.
Sizes available to fit all size cabinets.
Square hole pattern allows use of cable management
claws and rings.
NylonLoopFasteners
With the nylon loop fastener, secured sections of
cable are easily released, allowing individual cables
to be added or removed. Ideal for sensitive data
cables (fiber-optic/Cu), as it avoids indentations
on the cable sheathing. In addition, the nylon loop
fastener may be screw-fastened to the round
system punchings.
Color:
Black Also Required:
Screw 2486.500 for screw-fastening to the
round system punchings
 Lengthinches(mm) Packsof PartNo.
5.90 (150) 100 2597.000
Width Length Max. cable Packs
inches inches diameter of PartNo.
(mm) (mm) inches (mm)
0.63 (16) 5.11 (130) 1.18 (30) 10 7072.220
0.63 (16) 7.87 (200) 1.96 (50) 10 7072.230
0.63 (16) 11.81 (300) 3.54 (90) 10 7072.240
Cable Guide Rings
For flexible, system-compatible cable routing at the
side of the 19" (482.6 mm) mounting frame.
Material:
Sheet steel, zinc-plated, passivated
Includes:
10 cable guide rings, assembly parts
GermanPatentno.3813002
Dimensions Packsof PartNo.
inches (mm)
4.72 x 3.14 10 7111.900
(120 x 80)
4.72 x 2.36 10 7111.000
(120 x 60)
3.14 x 1.45 10 7112.000
(80 x 37)
Indicates its use with TS8 products Indicates its use with TE 7000 products
Width in (mm) Description Color PartNo.
23.62 (600) Roofmount Cable Manager RAL 7035 light grey 9970.253
23.62 (600) Roofmount Cable Manager Sand texture black 9970.254
27.56 (700) Roofmount Cable Manager RAL 7035 light grey 9970.255
27.56 (700) Roofmount Cable Manager Sand texture black 9970.256
31.50 (800) Roofmount Cable Manager RAL 7035 light grey 9970.257
31.50 (800) RoofmountCable Manager Sand texture black 9970.258
23.62 (600) Roofmount Ladder Rack RAL 7035 light grey 9970.263
23.62 (600) Roofmount Ladder Rack Sand texture black 9970.264
27.56 (700) Roofmount Ladder Rack RAL 7035 light grey 9970.265
27.56 (700) Roofmount Ladder Rack Sand texture black 9970.266
31.50 (800) Roofmount Ladder Rack RAL 7035 light grey 9970.267
31.50 (800) Roofmount Ladder Rack Sand texture black 9970.268
Different varieties are available: 600 Wide, 700 Wide,
800Wide,LCPWide,RAL7035,SandTextured
Black, Ladder rack capable, end plates.
Roofmount Manager End Covers RAL 7035 light grey 9970.259
Roofmount Manager End Covers Sand texture black 9970.260
RoofmountManagerLCPKit RAL 7035 light grey 9970.261
RoofmountManagerLCPKit Sand texture black 9970.262
Roofmount Manager Ladder Rack RAL 7035 light grey 9970.269
Roofmount Manager Ladder Rack Sand texture black 9970.270
12" W X 10' L Ladder Rack Sand texture black 9970.271
Enclosures
34 RimatriX5 IT Solutions
Enclosures
System Accessories Cable Management
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cable Routing Across the
19"(482.6mm)MountingLevel
Different cable collecting rails available to provide
orderly cable management in 19" systems:
C-Rails can be installed between all 19" mounting
surfaces.
CableClampRails to which cables are fastened
with cable ties, and can be installed between all 19"
mounting surfaces.
CableClampStrapsforTSMountingAngles
Cables are fastened with cable ties and have hooks
on side that hang in 19" rails.
C-rails Depth PartNo.
19" mounting surface - 7016.100
Cableclamprails Depth PartNo.
19" mounting surface - 7016.110
Cableclampstrap Depth PartNo.
TS mounting angles 4" (100 mm) 7016.130
19"(482.6mm)CableTroughs
For cable collection
Depth:
3.37" (85 mm)
Material:
Sheet steel
Color:
RAL 7035 light grey
19"(482.6mm)Cable
Entry Panels
Availablein2U(witha15.35x1.58"[390x40mm]
opening)or1U(witha15.35x0.79"[390x20mm]
opening). Has edge protector and brush insert to
protect against dust.
Material:
Sheet steel
Color:
RAL 7035 light grey
 U PartNo.
1 7149.135
3 7149.035
 U PartNo.
1 7140.535
2 7150.535
Indicates its use with TS8 products Indicates its use with TE 7000 products
Cable Entry Panel with Brush Insert
Color PartNo.
RAL 7035 light grey 7705.035
Cable Entry Panel with
Brush Insert
Multi-folded and welded, with foamed-on gasket and
plastic brush insert for easy cable entry.
Enclosures
RimatriX5 IT Solutions 35
Enclosures
System Accessories Cable Management
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicates its use with TS8 products Indicates its use with TE 7000 products
Cable Management Rail
Providesspaciouspossibilitiesforcableties,Velcro
strips and cable rings.
Easy installation – simply secure with screws to
system chassis or enclosure frame.
Material:
Sheet steel
Color:
Black
Size:
70.47 x 1.97" (1790 x 50 mm)
 Packsof PartNo.
2 9968.219
Enclosures
36 RimatriX5 IT Solutions
Enclosures
System Accessories Cable Management
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Stabilizers for Server Enclosures
The pullout stabilizer is quickly and easily retrofitted
to the base frame of a TS8 server enclosure and
only extended when necessary. It may be used in
combination with leveling feet and/or casters.
The stabilizer cannot be used with gland plates or
base/plinths.
LoadCapacity:
Uptoamaximumof330lbs(150kg)staticload
Material:
Sheet steel, zinc-plated, passivated
Includes:
1 stabilizer including assembly parts
DoorOperatingSwitch
Switches the enclosure light on when the door is
opened, and switches the air conditioner off to
prevent condensation.
Installation Technical
length data
Description inches (120V PartNo.
(mm) 60 Hz)
With interference 18.39 (467) 15 W 9968.108
suppression capacitor 24.41 (620) 18 W 9968.109
and no receptacle
With RFI filter, 18.39 (467) 15 W 9968.111
and no receptacle 24.41 (620) 18 W 9968.112
 U.S.receptacleand
lamp shade
PU PartNo.
Door operating switch 1 4127.000
without power cord
Enclosure Lights
Rittal’s new fluorescent lights are designed for quick
and easy installation. The external terminal block
means no need to disassemble the light to make
electrical connections. Available in 15 or 18 watt
rating, they can be used with or without the Rittal door
switch (see below). Equipped with interference
suppression capacitor or a RFI filter, they also come
withorwithoutalampshadeor115VU.S.style
receptacle.
Rating:
120V,60Hz
Light Medium:
Cool white
Includes:
Installation hardware
Connection Terminals:
L1,N.GND
On/off rocker switch
ULrecognizedforCanadianandU.S.requirements
Indicates its use with TS8 products Indicates its use with TE 7000 products
System Accessories Roof/Base/Sidewall Configuration
Enclosure depth PartNo.
36" (900 mm) 7825.200
40" (1000 mm) 7825.250
48" (1200 mm)7825.260
330 lbs
Enclosures
RimatriX5 IT Solutions 37
Enclosures
System Accessories System Lights
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicates its use with TS8 products Indicates its use with TE 7000 products
Sidewalls
Material:
Sheet steel, electrophoretic dipcoat-primed,
powder-coated
Color:
RAL 7035 light grey, Sand texture black
Includes:
2 side panels
Protection Category:
IP55
To complete individual enclosures
or bayed racks at the sides.
Sidewalls
H x D inches (mm) Color PartNo.
48 x 24 (1200 x 600) RAL 7035 light grey 8170.235
48 x 24 (1200 x 600) Sand texture black 9969.948
48 x 32 (1200 x 800) RAL 7035 light grey 8175.235
48 x 32 (1200 x 800) Sand texture black 9969.949
48 x 36 (1200 x 900) RAL 7035 light grey 9969.950
48 x 36 (1200 x 900) Sand texture black 9969.951
48 x 40 (1200 x 1000) RAL 7035 light grey 8176.235
48 x 40 (1200 x 1000) Sand texture black 9969.952
48 x 42 (1200 x 1050) RAL 7035 light grey 9969.953
48 x 42 (1200 x 1050) Sand texture black 9969.954
72 x 24 (1800 x 600) RAL 7035 light grey 8186.235
72 x 24 (1800 x 600) Sand texture black 9969.918
72 x 32 (1800 x 800) RAL 7035 light grey 8188.235
72 x 32 (1800 x 800) Sand texture black 9969.919
80 x 24 (2000 x 600) RAL 7035 light grey 8106.235
80 x 24 (2000 x 600) Sand texture black 9969.920
80 x 32 (2000 x 800) RAL 7035 light grey 8108.235
80 x 32 (2000 x 800) Sand texture black 9969.916
80 x 36 (2000 x 900) RAL 7035 light grey 8109.235
80 x 36 (2000 x 900) Sand texture black 9968.597
80 x 40 (2000 x 1000) RAL 7035 light grey 8100.235
80 x 40 (2000 x 1000) Sand texture black 9968.596
80 x 42 (2000 x 1050) RAL 7035 light grey 9969.309
80 x 42 (2000 x 1050) Sand texture black 9969.351
80 x 48 (2000 x 1200) RAL 7035 light grey 9969.955
80 x 48 (2000 x 1200) Sand texture black 9969.956
88 x 24 (2200 x 600) RAL 7035 light grey 8126.235
88 x 24 (2200 x 600) Sand texture black 9969.917
88 x 32 (2200 x 800) RAL 7035 light grey 8128.235
88 x 32 (2200 x 800) Sand texture black 9969.352
88 x 36 (2200 x 900) RAL 7035 light grey 9969.311
88 x 36 (2200 x 900) Sand texture black 9968.595
88 x 40 (2200 x 1000) RAL 7035 light grey 9968.593
88 x 40 (2200 x 1000) Sand texture black 9968.594
88 x 42 (2200 x 1050) RAL 7035 light grey 9969.312
88 x 42 (2200 x 1050) Sand texture black 9969.355
88 x 48 (2200 x 1200) RAL 7035 light grey 9969.957
88 x 48 (2200 x 1200) Sand texture black 9969.958
Sidewalls
To finish individual racks or entire bayed suites of
racks at the sides. The side walls are simply located
and secured with the integral lock. The super
lightweight design means that it is easily handled
by one person.
Material:
Sheet steel, powder coated
SupplyIncludes:
Security lock 3524 E
Protection Category:
IP20
For TE Height inches (mm) For TE Depth inches (mm) Packsof Color PartNo.
48 (1200) 24 (600) 2 RAL 7035 light grey 7000.642
48 (1200) 32 (800) 2 RAL 7035 light grey 7000.644
80 (2000) 24 (600) 2 RAL 7035 light grey 7000.650
80 (2000) 32 (800) 2 RAL 7035 light grey 7000.652
88 (2200) 24 (600) 2 RAL 7035 light grey 7000.654
88 (2200) 32 (800) 2 RAL 7035 light grey 7000.656
80 (2000) 40 (1000) 2 RAL 9005 black 7000.653
88 (2200) 40 (1000) 2 RAL 9005 black 7000.663
BlackcellsindicateRittalXpressproduct.
Enclosures
38 RimatriX5 IT Solutions
Enclosures
System Accessories Roof/Base/Sidewall Configuration
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicates its use with TS8 products Indicates its use with TE 7000 products
Module Plates, Solid
To conceal the entire roof or base area. The module
plate may be raised with spacers to support
ventilation.
Material:
Sheet steel
Color:
RAL 7035 light grey
Includes:
Assembly parts
Width (B) Depth (T) PartNo.
inches (mm) inches (mm)
17.72 (450) 17.72 (450) 7526.770
17.72 (450) 25.59 (650) 7526.780
25.59 (650) 17.72 (450) 7526.780
25.59 (650) 25.59 (650) 7526.820
Accessories:
Spacers, see Handbook 31
Note:
Configuration data on the next page
Partition Wall
For side partitioning of bayed TS server enclosures.
Installs without the need for additional hardware or
tools. Has 4 4.41 in (112 mm) cable passthrough
holes, grommet covers included.
Color:
Sand Textured black
Note:
UsebayingconnectorTS8800.490.Notforusein
conjunction with a baying seal. Any existing seals
must be removed prior to installation.
Module Plates
The module plates allow the roof or base area of the
TE 7000, in exchange for the existing roof plate, to be
varied as required. The module plates may be raised
with spaces to support ventilation.
Material:
Sheet steel
Color:
RAL 7035 light grey, on request in RAL 9005 black
Includes:
Assembly parts
Note:
Configuration data below.
Also Required:
For a completely sealed roof/base assembly,
compensating plate is required
Accessories:
Spacers, see Handbook 31
Configuration
Roof/Base Frame for TE 7000 Enclosures
W(B) 23.62 (600) 23.62 (600) 31.49 (800) 31.49 (800)
D(T) 23.62 (600) 31.49 (800) 23.62 (600) 31.49 (800)
3 x module plates 2 x module plates
Installation 2 x module plates in the width or in the width 3 x module plates
position/ in the width or depth 2 x module plates or 3 x module plates in the width or depth
enclosure plus 1 x compensating in the depth in the depth plus 1 x compensating
plate in each case plus 1 x compensating plus 1 x compensating plate in each case
plate in each case plate in each case
Enclosure
dimensions
inches (mm)
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
Version Width Depth PartNo.
inches (mm) inches (mm)
Solid 17.72 (450) 7.87 (200) 7526.760
25.59 (650) 7.87 (200) 7526.800
With Brush 17.72 (450) 7.87 (200) 7526.850
Strips 25.59 (650) 7.87 (200) 7526.860
Compensating 17.72 (450) 1.97 (50) 7526.750
Plate 25.59 (650) 1.97 (50) 7526.790
Height in (mm) Depth in (mm) PartNo.
80 (2000) 36 (900) 9971.041
80 (2000) 40 (1000) 9971.042
80 (2000) 42 (1050) 9971.043
80 (2000) 48 (1200) 9971.044
88 (2200) 36 (900) 9971.045
88 (2200) 40 (1000) 9971.046
88 (2200) 42 (1050) 9971.047
88 (2200) 48 (1200) 9971.048
Enclosures
RimatriX5 IT Solutions 39
Enclosures
System Accessories Roof/Base/Sidewall Configuration
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
Bolt Down Kits
For anchoring the enclosure even if it is on casters,
at any position of the base frame. Has a vertical slot
to account for different vertical positions.
Material:
Sheet steel, E-coated
 PU PartNo.
4 9970.989
 PU PartNo.
4 8800.830
For use in addition to clamping straps for stabiliza-
tion when populated enclosures are screw-fastened
through the base tray to the base/plinth or pallet for
transportation purposes.
Material:
Sheet steel, zinc-plated, passivated
Note:
Additional holes in the base are required for mounting
Configuration:
Assembly hardware
BlackcellsindicateRittalXpressproduct.
Toolless Blanking Panels
To place in unused or vacant rack space, to block
off airflow. Installs without the need for additional
hardware or tools.
Air Brush Baffles
Designed to block air and redirect it where needed.
Designed to mount to the z-rail on the top, bottom,
and both sides.
•Easyinstallation
•Availablefor80"and88"servercabinets
•StandardinLCPreadycabinet
U Packsof Color PartNo.
1 10 Sand texture black 9970.016
3 5 Sand texture black 9970.017
1 10 RAL 7035 light grey 9970.240
3 5 RAL 7035 light grey 9970.241
Height x Width PartNo.
80 (2000) x 24 (600) 9961.328
80 (2000) x 28 (700) 9961.329
80 (2000) x 32 (800) 9961.330
80 (2000) x 24 (600) 9961.331
88 (2200) x 28 (700) 9961.332
88 (2200) x 32 (800) 9961.333
Brush ring 4.41" (112 mm) 9961.334
Snap ring grommet 9961.326
Side Breathing Air Baffle System
•Itisdesignedtoredirecthotexhaustfromside
breathing equipment out the back of the cabinet
•Designedforhotaisle/coldaisleinstallations
•ToollessInstallation
•Depthadjustable
•Designedforupto12Usidebreathingequipment
•Mountsin0Uspace
•Designedforusewith32"(800mm)widecabinets
Packsof PartNo.
19960.552
CC
712.00
912.00
742.00 23.90
140.30
879.56
18.97
126.03
1912.00
712.00
356.00
221.00
450.00
219.50
34.00
3.00
CC
712.00
912.00
742.00 23.90
140.30
879.56
18.97
126.03
1912.00
712.00
356.00
221.00
450.00
219.50
34.00
3.00
Enclosures
System Accessories Roof/Base/Sidewall Configuration
40 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosures
BluecellsindicateAitems.
BlackcellsindicateRittalXpressproduct.
TransportCasters
For easy transportation between two locations. The
casters may additionally be screw-fastened to the
leveling feet in the corner areas of the base frame.
LoadCapacity:
660 lbs (300 kg), static
SupplyIncludes:
1 set = 4 transport casters, assembly parts
Twin Casters
For TS8 Data Rack
Mounting Thread:
M12 x 20
SupplyIncludes:
1 set = 4 transport casters, assembly parts
 Packsof PartNo.
1 set 7000.672
Kit includes PartNo.
4 casters /1 wrench 9968.751
Leveling Feet
Compensate for uneven floors and can be mounted
on enclosure or on base.
Length of Thread:
2" (51 mm)
LoadCapacity:
800 lbs (363 kg) each
Caster Kit
Casters help simple movement on even floors. Easy
to install. Kit includes hardware, left and right rigid
casters and two swivel casters.
LoadCapacity:
825 lbs (374 kg) each
 For Packsof PartNo.
TS 4 9968.385
MaxiumLoadCapacity Ground Clearance Lock Packs of Color PartNo.
perCaster(lbs) inches (mm)
     88 1.96(50) 4 w/out 1 set black 4611.000
   165 3.35(85) 2 with 1 set black w/ 6148.000
2 w/out grey surface
   264 4.92(125) 2 with 1 set black 4634.500
2 w/out 7495.000
Also Required:
For mounting on the TS base/plinth:
Base/plinth adapter for twin caster 8800.290,
see Handbook 31
1
2
3
4
1
TypeofThread:
M12
RimatriX5 IT Solutions 41
Enclosures
Wallmount Enclosures EL3-PartAccessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BlackcellsindicateRittalXpressproduct.
Indicates its use with TS8 products Indicates its use with TE 7000 products
Slide Rails
For mounting between a front and a rear pair of
mounting angles. The slide rails can be used to
support heavy 19" (482.6 mm) components.
H x W: 3.15 x 3.35" (80 x 85 mm)
LoadCapacity:
176 lbs (80 kg)
Material:
Sheet steel, zinc-plated, passivated
Includes:
2 slide rails, assembly parts
Length 19" (482.6 mm) distance
inches betweenlevels Packsof PartNo.
(mm) inches (mm)
12.75 (324) 15.55 (395) 2 7963.310
16.69 (424) 19.49 (495)1) 2 7963.410
20.63 (524) 23.43 (595) 2 7963.510
24.57 (624) 27.36 (695) 2 7963.610
1)Premiumaccessories:adirectfitforenclosuresintheir
delivered state.
SlideRails,Depth-Variable,1U
These slide rails facilitate flexible integration of
19" (482.6 mm) components without loss of
installation height in all enclosures with L-shaped
mounting angles or 19" (482.6 mm) mounting frames
in enclosure series TS8 & TE and their server variants.
Installation of the slide rail is independent from the
chosen distance between levels, since the installation
length may be flexibly adapted.
Material:
Sheet steel
Surface Finish:
Sheet steel, zinc-plated, passivated
Includes:
2 slide rails, including assembly parts
Length Load Contact surface
inches (mm) capacity W x D PartNo.
inches (mm)
23.23 x 36.61 330 lbs 1.96 x 20.66 7063.884
(590 x 930) (150 kg) (50 x 525)
Possible Alternative:
Depth-variable slide rail, see below
Heavy-DutySupportRails
(TelescopicSlides)
These telescopic support rails are designed to
support components from underneath, and can
support up to 200 lbs (91 kg). Rails extend from
22.07" (560.5 mm), totally retracted, to 30" (762 mm),
totally extended.
Packsof PartNo.
29968.837
Includes:
2 support rails
For Packs
enclosure Length of PartNo.
width
23.60" (600 mm) 15.70" (400 mm) 2 7502.304
Combination Cable
Collecting Rails
These rails make it possible to fasten cables with
cable clamps or cable ties and allow bonding
between the cable shield and ground bus.
Material:
Aluminum, zinc-coated, chromated
Includes:
Combination rail, installation hardware
Enclosures
42 RimatriX5 IT Solutions
Enclosures
System Accessories Interior Installation
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicates its use with TS8 products Indicates its use with TE 7000 products
TS System Chassis with
MountingFlange0.66x2.87"
(17x73mm)
For designing a flexible interior installation, or for
accommodating additional components. The punched
sections with mounting flanges may be attached
directly onto a 19" (482.6 mm) mounting frame hori-
zontally at the rear or in the enclosure depth between
two mounting frames. An additional screw fastening
secures the unit.
Variable,with5rowsofholesforuniversalskeleton
structure or partial assembly.
Material:
Sheet steel, zinc-plated, passivated
Includes:
Assembly parts
GermanPatentno.19647802
Note:
When selecting a distance between levels outside of
the mounting attachment points, it is advisable to use
the depth-variable punched section with mounting
flange, see below.
TS System Chassis with
MountingFlange0.66x2.87"
(17x73mm)
Depth-VariableforMountingFrames
For designing flexible interior installation, and/or to
accommodate additional built-in components. The
punched sections with mounting flanges may be
located in the enclosure depth between two mounting
frames. An additional screw fastening secures the unit.
The depth variability of the rails allows for flexible
adaptation of their length to the existing attachment
distance between the two 19" (482.6 mm) mounting
frames. An additional punched section center piece
may be slid flexibly along the rail in the depth and
secured to slots. This facilitates flexible attachment
at any point between the mounting frames in the
enclosure depth.
19" (482.6 mm)
 distancebetween Packsof PartNo.
levels inches (mm)
16.54 – 23.23 (420 – 590) 2 7000.676
25.59 – 32.28 (650 – 820) 2 7000.678
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
2 variable punched sections with mounting flanges,
including one movable center part in each case,
including assembly parts
For inner mounting level
Enclosure Packs
PartNo.
width/depth of
inches (mm)
24 (600) 4 8612.060
32 (800) 4 8612.080
36 (900) 4 8612.090
40 (1000) 4 8612.000
48 (1200) 4 8612.020
For outer mounting level1
Enclosure Packs
PartNo.
width/depth of
inches (mm)
24 (600) 4 8612.160
32 (800) 4 8612.180
40 (1000) 4 8612.100
48 (1200) 4 8612.120
NOTE:
1) In conjuction with plug-in side panels, notched punched
sections are required
AdapterRail
forPScompatibility
Installation in the vertical TS enclosure sections
(across the entire enclosure height or in subsections)
to create compatibility with:
•PSpunchedrail,0.91x0.91"(23x23mm)
•PSpunchedsectionwithoutmountingflange,
0.91 x 2.87" (23 x 73 mm)
•PSpunchedsectionwithmountingflange,
0.91 x 0.91" (23 x 23 mm)
For enclosure height Packsof PartNo.
72" (1800 mm) 4 8800.380
80" (2000 mm) 4 8800.300
88" (2200 mm) 4 8800.320
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
Assembly screws
Enclosures
RimatriX5 IT Solutions 43
Enclosures
System Accessories Interior Installation
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicates its use with TS8 products Indicates its use with TE 7000 products
Mounting Kit
For19"(482.6mm)equipment
Facilitates fast, simple integration of additional
mounting space within an enclosure by attaching
to the enclosure frame or to the existing mounting
angles at the sides. The flexible slot fastening of
the brackets means that the distance between the
two installation brackets may be freely selected,
so that other 19" (482.6 mm) attachment dimensions
may be implemented.
The second row of holes is used for the optional
configuration of additional mounting surfaces.
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
Assembly parts
PSPunchedRails0.91x0.91"
(23x23mm)
InstallationOptions:
•Ontheverticalenclosuresection
Directly via support brackets TS
−ViaadapterrailforPScompatibilityinconjunction
with angle brackets, mounting brackets or support
bracketsPS
•Onthehorizontalenclosuresection
Directly via angle brackets, mounting brackets or
supportbracketsPS
Length
in (mm) For WHD
in (mm) Packs
of PartNo.
74.61 (1895) 78.74 (2000) 6 4177.000
81.52 (2095) 85.60 (2200) 6 4178.000
Material:
Sheet steel, zinc-plated, passivated
Mounting Bracket PS
For variable attachment of punched rails
0.91 x 0.91" (23 x 23 mm).
InstallationOptions:
•Optionallyflushwith:
Outer enclosure edge or
Enclosure clearance width
•OntheverticalTSenclosuresectionvia
−AdapterrailforPScompatibility
•OnthehorizontalTSenclosuresection
•Onenclosuresandrailswithsquaresystem
punchings 0.49 x 0.41" (12.5 x 10.5 mm).
Packsof PartNo.
24 sets 4182.000
Material:
Die-cast zinc
SupplyIncludes:
1 set = 1 mounting bracket, 1 screw M6 x 0.47" (12 mm),
1 cage nut M6.
U Nuts
for:
•Punchedrail0.91x0.91"(23x23mm)
•Punchedsectionwithoutmountingflange,
0.91 x 2.87" (23 x 73 mm)
•Punchedsectionwithoutmountingflange,
1.77 x 3.46" (45 x 88 mm)
•Punchedsectionwithmountingflange,
0.91 x 2.87" (23 x 73 mm)
For mounting punched rails and punched sections
without mounting flanges on angle brackets, mounting
bracketsandsupportbrackets,werecommendU
nuts with M6 thread (4179.000).
Thread Packsof PartNo.
M4 20 4119.000
M5 20 4157.000
M6 20 4179.000
M8 20 4180.000
UColor Packs PartNo.
1 Black 2 9970.986
2 Sheet steel 2 7856.026
Enclosures
44 RimatriX5 IT Solutions
Enclosures
System Accessories Interior Installation
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicates its use with TS8 products Indicates its use with TE 7000 products
Mounting Plate
Locatable
On the vertical TS enclosure section or TS punched
section with mounting flange 0.66 x 2.87" (17 x 73 mm)
on the inner and outer mounting level.
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
Assembly screws
Mounting Plate
Screw-Fastened, Large
On all enclosures and mounting parts with system
punchings on a 0.98" (25 mm) pitch pattern.
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
Assembly screws
Mounting Plate
Screw-Fastened, Small
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
Assembly screws
 Packsof PartNo.
4 8612.400
 Packsof PartNo.
4 8612.410
t = 1.5
10.5
40
12.5
6 (5 x)
12.5
110
25
100
50
60
4.6 6
Ø 6.5
Ø 4.6
12.5
12.5
100 = 8 x 12.5
100 = 8 x 12.5
125
10
60
110
120
Ø 7
5.6
t = 2
Ø 6.5
Ø 4.6
100 = 8 x 12.5
118
12.5
100 = 8 x 12.5
118
5.6
5.6
12.5
t = 2
 Packsof PartNo.
4 4532.000
Mounting Bracket
Screw-fastened on all enclosures and mounting
parts with system punchings on a 0.98" (25 mm)
pitch pattern.
Material:
Sheet steel, zinc-plated, passivated
SupplyIncludes:
Assembly screws
100
110
53
25
12.5
6 (3 x)
25
40
12.5
16.5
12.5
4.6
6
10.5
16.5
18
1.5
28
 Packsof PartNo.
4 4597.000
Button Mount Brackets
•EnablestoollessinstallationofPDUs
•Allow0UmountingofPDUs
•Black,E-coated
Description PartNo.
0U,z-railbuttonmountbracket,
quantity 2 per package 9971.066
0U,dualbuttonmountbracket,
quantity 2 per package 9971.067
Enclosures
RimatriX5 IT Solutions 45
Enclosures
System Accessories Interior Installation
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BluecellsindicateAitems.
 Packsof PartNo.
1 kit 7000.640
Baying Kit
For connecting individual enclosures into bayed
suites at the sides. The enclosures are mounted
between the base and roof frame.
Material:
Sheet steel, zinc-plated, passivated
Includes:
1 set of baying connectors
 Version Packsof PartNo.
Sheet steel 6 8800.490
Stainless steel 6 8700.000
GermanPatentNo.19737668
BayingConnectors,External
For mounting on the vertical enclosure sections.
Simply position on the outside and screw. Fasten
either from the inside or outside.
Material:
Sheet steel, zinc-plated, passivated or
stainless steel 1.4301
Includes:
Assembly parts
 Packsof PartNo.
4 4582.500
Baying Bracket
For additional stabilization or in cases where:
•mountingbrackets
•swingframes
•busbarsupports
prevent the installation of angular baying brackets.
Material:
Sheet steel, zinc-plated, passivated
Includes:
Assembly parts
Accessories:
For mounting on vertical TS enclosure: Snap-on nut
M8, 8800.808, see Handbook 31
Indicates its use with TS8 products Indicates its use with TE 7000 products
Enclosures
Enclosures
System Accessories Baying Components
46 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BlackcellsindicateRittalXpressproduct.
BluecellsindicateAitems.
BlackcellsindicateRittalXpressproduct.
CompleteGroundingKits
For system-compatible grounding of all enclosure
partsontheenclosureframeaccordingtoVDE.
The ground conductors are pre-assembled, ready
for connection with connectors and cut to the
correct length.
Includes:
Assembly parts
 Models Packsof PartNo.
TE 1 kit 7000.675
TS 1 kit 7829.150
Indicates its use with TS8 products Indicates its use with TE 7000 products
TorxScrews
For the round holes in the TS profile, installation rails
and system chassis without mounting flanges.
Self-TappingScrews
For the round holes in the TS profile, installation rails
and punched sections without mounting flanges.
Drilling Screws
Mark, drill and tighten in a single move using electric
or pneumatic tools.
For metal thickness: 0.32 – .12" (8 – 3 mm)
Length: 0.63" (16 mm)
Usablelength: 0.37"(9.50mm)
Width across flats: 0.32" (8 mm)
Torx drive for optimum transmission of torques, an
extended tool life and increased safety and reliability
when tightening and loosening screw connections.
AssemblyScrewsM6x16mm,
M5x16mm
For captive nuts, 19" (482.6 mm) enclosure mount
componentsandblankingpanels.Plasticwashers
included.
 Type Packsof PartNo.
Slotted screw M6 100 2093.200
 PhillipsscrewM6 100 2089.000
 PhillipsscrewM5 100 2099.500
 Typeofscrew Dimensions Packsof PartNo.
Torx screws M6 x 300 2504.500
12 mm
Torx screws BZ5.5x300 2486.500
13 mm
Self-TappingScrews  
Hex screws M5 x 500 2504.000
10 mm
Posidriveraised M5 x
countersunk 12 mm 500 2488.000
screws
 Panhead M5 x
screws, 12 mm 500 2489.000
posidrive
Self-tapping 300 2487.000
screws
CaptiveNutM5
Design For metal
thicknesses
inches (mm)
Packs
of Part
No.
With contact .03 – .08 (0.8 – 2.0) 50 2094.500
Without contact .03 – .08 (0.8 – 2.0) 50 2092.500
CaptiveNutM6
Design For metal
thicknesses
inches (mm)
Packs
of Part
No.
With contact .03 – .08 (0.8 – 2.0) 50 2094.200
Without contact .03 – .08 (0.8 – 2.0) 50 2092.200
With contact .05 – .06 (1.2 – 1.5) 50 2094.300
Without contact .05 – .06 (1.2 – 1.5) 50 2092.300
CaptiveNut10/32
Without contact .03 – .08 (.8 – 2.0) 50 9957.324
CaptiveNutsM5/M6
For the attachment of rack-mounted electronic
equipment, 19" (482.6 mm) installed equipment and
blanking plates to mounting angles, 19" (482.6 mm).
For use with metal thickness from .03 – .08"
(0.8 – 2.0 mm). In areas of narrow tolerance, captive
nuts for metal thicknesses of .05 – .06" (1.2 – 1.5 mm)
should be used. Optionally with or without contact of
the installed equipment to the 19" (482.6 mm)
section/enclosure.
Enclosures
RimatriX5 IT Solutions 47
Enclosures
System Accessories Grounding
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BlackcellsindicateRittalXpressproduct.
BluecellsindicateAitems.
BluecellsindicateAitems.
Toolless Shelves
For19"(482.6mm)
Rackmounting
These 19" (482.6 mm) enclosure mount shelves are
designed for your ease – the toolless advantage
allows quick and simple assembly.
LoadCapacity:
150 lbs (68 kg)
Mounting Color PartNo.
Fixed RAL 7035 light grey 9968.421
Fixed Cool black 9968.422
19" (482.6 mm)
H x W x D distance between Packs PartNo.
inches (mm) levels inches (mm) of
0.87 x 20.16 x 1.57 19.49 (495) 1 7000.620
(22 x 512 x 40)
ComponentShelf
Static Installation for Mounting Frames
For fast integration of a component shelf and to
accommodate a wide variety of built-in components.
Combination with telescopic slides is not possible.
The component shelf is attached directly to the front
and rear 19" (482.6 mm) mounting frame. To this
end, it is first necessary to secure the 19" (482.6 mm)
mounting frames at the corresponding distance from
one another.
LoadCapacity:
130 lbs (59 kg), static
Material:
Sheet steel, spray-finished
Color:
RAL 7035 light grey
Includes:
1 component shelf, assembly parts
Heavy-Duty Toolless Shelves
For19"(482.6mm)
Rackmounting
These 19" (482.6 mm) heavy-duty enclosure mount
shelves are designed for your ease. The toolless
advantage allows quick and simple assembly.
LoadCapacity:
250 lbs (113 kg)
Mounting Color PartNo.
Fixed RAL 7035 light grey 9968.556
Fixed Cool black 9968.557
Telescopic RAL 7035 light grey 9968.586
Telescopic Cool black 9968.587
Fixed RAL 7035 light grey 9967.920
Indicates its use with TS8 products Indicates its use with TE 7000 products
Enclosures
Enclosures
System Accessories Shelves
48 RimatriX5 IT Solutions
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ComponentShelves,1/2U,
Depth-Variable
These space-saving component shelves are screw-
fastened to the front and rear 19" (482.6 mm)
attachment level. They are infinitely depth-adjustable
and may be fitted independently from the enclosure.
Combination with telescopic slides is not possible.
LoadCapacity:
110 lbs surface load, static
Material:
Sheet steel
Distance between levels PartNo.
inches (mm)
15.74 – 23.62 (400 – 600) 7063.710
23.62 – 35.43 (600 – 900) 7063.720
Surface Finish:
Spray-finished, RAL 7035 light grey
Includes:
Component shelf, including assembly parts
ComponentShelves,2U
Static Installation
If only one pair of 19" (482.6 mm) mounting angles is
available for mounting a component shelf, this variant
offers a particularly cost-effective solution. Installation
of telescopic slides is not possible.
LoadCapacity:
55 lbs (25 kg) surface load, static
Material:
Sheet steel, spray-finished
Color:
RAL 7035 light grey
Also Required:
Screws, captive nuts
ComponentShelf,2U
StaticInstallationorFullyExtendable
Suitable for installation in all enclosures with only one
19" (482.6 mm) location point via flange mounting.
LoadCapacity:
55 lbs (25 kg) surface load, static
Material:
Sheet steel, spray-finished
Color:
RAL 7035 light grey
StaticInstallationorFullyExtendable1)
Width x depth PartNo.
inches (mm)
15.35 x 12 (390 x 300) 7148.035
1) For fully extendable version, telescopic slides 7051.000 should be
ordered additionally.
Component shelf depth PartNo.
inches (mm)
10 (250) 7119.250
16 (400) 7119.400
Includes:
1 set =1 component shelf, 2 installation brackets,
assembly parts
Accessories:
Telescopic slides
Indicates its use with TS8 products Indicates its use with TE 7000 products
VentedComponentShelveswith19"(482.6mm)
Railmounting
inches mm PartNo.
W D W D
16 12 400 300 7143.035
16 16 400 400 7144.035
16 20 400 500 7145.035
BlackcellsindicateRittalXpressproduct.
BluecellsindicateAitems.
BluecellsindicateAitems.
Enclosures
RimatriX5 IT Solutions 49
Enclosures
System Accessories Shelves
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BluecellsindicateAitems.
BluecellsindicateAitems.
Indicates its use with TS8 products Indicates its use with TE 7000 products
TelescopicSlidesfor
ComponentShelves
Sides are fully extendable, and can also be easily
retrofitted to convert fixed shelf into sliding shelf.
Available in two versions:
max. load capacity: 110 lbs (50 kg)
max. load capacity: 220 lbs (100 kg)
TechnicalDescription:
•Installationadjustablein0.98"(25mm)increments
•2-stageextension
Forshelf Packs PartNo.
depth of max. load capacity
110 lbs (50 kg) 220 lbs (100 kg)
12" (300 mm) 1 set 7051.000 -
16" (400 mm) 1 set 7061.000 7064.000
20" (500 mm) 1 set 7081.000 7065.000
24" (600 mm) 1 set 7161.000 7066.000
HandleforComponentShelves
Material:
Die-cast zinc
Includes:
Installation hardware. All component shelves have
mounting holes for handles.
 Packsof PartNo.
2 3636.010
Material:
Sheet steel, zinc-coated, chromated
ComponentShelves,
19"(482.6mm)Configuration
The component shelves may be inserted in network
enclosures with two pairs of 19" (482.6 mm) mounting
angles.
The component shelves offer a number of location
points depending on their depth, so that the distance
between levels is completely variable in conjunction
with the depth-variable installation kit. Each compo-
nent shelf secured in this way can be retrospectively
upgraded to full withdrawal using telescopic slides.
For this purpose, the telescopic slides are screw-
fastened in place of the spacers.
LoadCapacity:
110 lbs (50 kg) or 220 lbs (100 kg) surface
load, static
Material:
Sheet steel
Color:
RAL 7035 light grey
Includes:
Component shelf including spacers for
static installation
Also Required:
Depth-variable installation kit, see next page
Component shelf width inches (mm) 16.10 (409)
Component shelf depth (T) inches (mm) 11.81 (300) 15.74 (400) 19.68 (500) 23.62 (600) 27.55 (700)
 PartNo.110lbsShelf 7143.035 7144.035 7145.035 7145.635 7145.735
 PartNo.220lbsShelf 7063.895 7063.897
Handle for component shelf 3636.010 3636.010 3636.010 3636.010 3636.010
Telescopic slides 50 kg (110 lbs) 7051.000 7061.000 7081.000 7161.000 7161.700
Telescopic slides 100 kg (220 lbs) 7065.000 7066.700
Enclosures
50 RimatriX5 IT Solutions
Enclosures
System Accessories Shelves
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
BluecellsindicateAitems.
BluecellsindicateAitems.
Hinged Cable Carriers
For component shelves on telescopic slides and
forprintercarriages.Preventscablesfromsagging
and kinking.
Includes:
Installation hardware
Material:
Sheet steel, zinc-coated, passivated
For enclosure PartNo.
inches (mm)
24 (<600) 7163.500
24 (>600) 7163.550
InstallationKits,Depth-Variable
For19"(482.6mm)ComponentShelves
Infinitely adjustable to the spacing between the two
pairs of 19" (482.6 mm) mounting angles.
Suitable for all 19" (482.6 mm) component shelves in
16.10" (409 mm) width. May also be combined with
telescopic slides.
Material:
Sheet steel
Surface Finish:
Zinc-plated,passivated
Includes:
1 set = 2 mounting rails, including assembly parts
Indicates its use with TS8 products Indicates its use with TE 7000 products
Accessories:
For Component shelves, 19" (482.6 mm),
and Telescopic slides, see previous page.
Length
inches (mm) Load Capacity
lbs (kg) PartNo.
15.75 – 23.62
(400 – 600) 110 (50) 7063.858
23.62 – 33.46
(600 – 850) 110 (50) 7063.860
24.01 – 35.43
(610 – 900) 220 (110) 7063.8911)
27.95 – 39.37
(710 – 1000) 220 (110) 7063.890
21.7 – 33.5
(500 – 850) 220 (110) 7063.850
Packsof1set
1) Only in conjunction with 19.68" (500 mm) deep
component shelves
Keyboard Drawer, 2U
for a 19" (482.6 mm) attachment level
For keyboards up to 16.93" (430 mm) wide
and 9.84" (250 mm) deep with the front
panel folded over.
Material:
Sheet steel with aluminium front, spray-finished in
RAL 7035 light grey.
Height PartNo.
2U 7281.035
SupplyIncludes:
Lockable drawer with handles,
folding front,
pull-out mouse pad,
mouse support,
practical cable entry
and strain relief.
Enclosures
RimatriX5 IT Solutions 51
Enclosures
System Accessories Shelves
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
52 RimatriX5 IT Solutions
Cooling
RimatriX5 IT Solutions from Rittal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Liquid Cooling
LiquidCoolingPackage(LCP)Solution .......................................................................................... 54
Rittal Enclosure Blower
Rittal Enclosure Blower ................................................................................................................... 57
DualPowerTransferSwitch ............................................................................................................ 57
Fan Systems
Split Rear Door Fan ........................................................................................................................ 58
Roof Fan ......................................................................................................................................... 58
Server Fan Assembly ..................................................................................................................... 58
Fan Expansion Kit .......................................................................................................................... 59
TE Roof Fan .................................................................................................................................... 59
DCFanMountingPlate ................................................................................................................... 60
Air Conditioners
Wallmounted Air Conditioners .........................................................................................................61
Roofmounted Air Conditioners ....................................................................................................... 64
Accessories
Cooling Accessories ....................................................................................................................... 68
Heat is just one of the many factors severely affecting IT performance. Beat the
heat with Rittal’s scalable climate control solutions. From passive air to active liquid,
Rittal’s flexible cooling concepts are designed according to your requirements, to
effectively handle unwanted heat loads.
Software assisted planning and requirements calculation, together with modular,
rack-compatible technology help to minimize investment costs, thereby offering a
particularly future-safe solution, thanks to the high degree of flexibility.
RimatriX5 IT Solutions 53
Cooling
RimatriX5 IT Solutions from Rittal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
* Cold water chillers and water/water HX available upon request
*SNMPmonitoredorcontrollablepowerstripsavailableuponrequest
T
B
H
LCPExtend
LCP Standard
LCP Plus
Modularclimatecontrolconcepts–toyourspecific
requirements!
Rittal RimatriX5 solves the problem of climate control for
highheatlossesperrackwiththeLiquidCoolingPackage
(LCP)range.Extremelyhighheatloadsaredissipatedfrom
therackviatheLCPair/waterheatexchanger.Additionally,
this system also allows temperature-neutral expansion of
the data center.
Installationwhileoperational
Air/water heat exchanger (10 kW) to
support climate control of the room.
For Rittal racks, the relevant door is
preconfigured in the factory and
exchanged on site.
Suitable for use on any surface
The stand-alone unit may be fitted
onto any suitably sized rear door
(including other brands).
Water connection variants
Water connection either at the
bottom or top. Connection to the
existing cooling circuit (optionally
via water/water heat exchanger)
or to recooling systems.
Bayable with TS 8 server racks
As the height and depth are
identical, it may be bayed either
in the middle of an enclosure suite
or at the end, for added assembly
and service-friendliness.
Upto20kWusefulcoolingoutput
The useful cooling output is
achieved with a modular
configuration (1 – 3 modules).
Active condensate management
supports inlet temperatures from
43°F to 68°F (+6°C to +20°C).
Safeinsertion,simpleassembly
The separation of cooling and rack
prevents water from penetrating
the server rack. A recooling system
supplies the required cooling fluid.
Upto40kWusefulcoolingoutput
Usefulcoolingoutputsof28kW
(rack height 78.74" [2000 mm])
or 40 kW (rack height 94.49"
[2400 mm]) are achieved with 6
or 8 high-performance fans, which
may be exchanged without the
needfortools.Overall,theLCPPlus
has been optimized for use in data
centers. Even with the enclosure
doors open, e.g., during servicing
work on servers, climate control is
100% guaranteed.
54 RimatriX5 IT Solutions
Cooling
RittalLiquidCoolingPackage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
B = Width
H = Height
T = Depth
B = Width
H = Height
T = Depth
B = Width
H = Height
T = Depth
T
B
H
LCPExtend
Air/water heat exchanger for retrofitting to racks
while operational.
The stand-alone unit may be fitted onto any rear
doors (including other brands).
For Rittal racks, the relevant door is preconfig-
ured in the factory ready to be connected and
exchanged on site.
TechnicalSpecifications:
•Upto10kWusefulcoolingoutput
•Max.airvolume1767cfm(3000m3/h)
•Waterconnectioneitheratthebottomortop
LCP Standard
Air/water heat exchanger, bayable with
server racks based on TS8.
The useful cooling output of max. 20 kW can be
achieved by installing additional modules.
The separation of cooling and rack prevents
water from penetrating the server rack, and
makes it more assembly and service-friendly.
LCPsareeasytohandle(max.6.5'[2m])and
may be transported in lifts and through doors.
The low weight means a minimal area load.
TechnicalSpecifications:
•Upto20kWusefulcoolingoutput
•Max.airvolume1767cfm(3000m3/h)
•TÜVGS,UL/CUL,DIN3168
LCP Plus
Air/water heat exchanger, bayable with server
racks based on TS8. Complete unit with 28 kW
useful cooling output.
The separation of cooling and rack prevents
water from penetrating the server rack, and
makes it more assembly and service-friendly.
LCPsareeasytohandle(max.6.5'[2m])and
may be transported in lifts and through doors.
The low weight means a minimal area load.
TechnicalSpecifications:
•Upto28kWusefulcoolingoutput
•Max.airvolume2827cfm(4800m3/h)
H
B
T
T
B
H
RimatriX5 IT Solutions 55
Cooling
RittalLiquidCoolingPackage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
PartNo. 3301.4901) 3301.230 3301.420 3301.4801) on request
Description LCPExtend LCPStandard LCPPlus LCPPlus
RatedoperatingvoltageV,Hz 230, 50/60 230, 50/60 230, 50/60 230, 50/60
B
Dimensions in inches (mm) H
D
20.47 (520)
75.20 (1910)
6.30 (160)
11.81 (300)
78.74 (2000)
39.37 (1000)
11.81 (300)
78.74 (2000)
47.24 (1200)
11.81 (300)
78.74 (2000)
47.24 (1200)
11.81 (300)
94.49 (2400)
47.24 (1200)
UsableU 42 42 42 51
Usefulcoolingoutput 10 kW Upto20kW Upto28kW Upto40kW
Rated current 2.4 A/3.0 A 3.8 A/4.4 A 9.3 A/10.4 A
Technical specifications
on request.
Pre-fuse 6 A/6 A 10 A/10 A 16 A/16 A
Cooling medium Water (for specifications see Internet)
Water inlet temperature 59°F (+15°C) 43°F to 68°F (+6°C to +20°C)
Permissibleoperatingpressurep.max. 87 psi (6 bar) 87 psi (6 bar) 87 psi (6 bar)
ProtectioncategorytoEN60529/10.91 IP30
Duty cycle 100 %
Electrical connection Connection cable
Water connection 3/4" external thread 1" external thread
Weight 99 lb (45 kg) max. 376 lb (170 kg) 332 lb (150 kg)
Color RAL 7035 light grey
Air throughput of fans 1767 cfm (3000 m3/h) 2827 cfm (4800 m3/h)
Temperature control Fan control Electronically controlled magnetic valve and 4-way fan control
Additional module
Usefulcoolingoutput4kW
(59°F [15°C], .28 cfm [8 l/min]) 3301.250
Special voltages and sizes available on request. Technical modifications reserved.
Rack heights of 88" (2200 mm) are achieved with an optional add-on cover.
1) Delivery times available on request.
ForLCPReadyCabinet,seepage18.
Covers
For sealing any air inlet and outlet openings of the
LCPthatarenotrequired.
Material:
Sheet steel, spray finished in RAL 7035
Add-On Cover
For height compensation with 88" (2200 mm)
highracksinconjunctionwiththeLCP
(H = 80" [2000 mm]).
Material:
Sheet steel, spray finished in RAL 7035
Packsof PartNo.
23301.310
ForLCP PartNo.
3301.210 3301.221
3301.230
3301.420 3301.421
3301.480
Delivery times available on request.
56 RimatriX5 IT Solutions
Cooling
RittalLiquidCoolingPackage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Rittal’sEnclosureBlowerfiltersupto80%efficiencyfor2micron
particlesprovidingcleancoolairtoyourservers.Filterassembly
featuresdurableconstructionwithsimplehandtoolassembly.
Thereplaceablefiltersinstallwithouttools.
Rittal Enclosure Blower
Assist airflow in your cabinets with the Rittal Enclosure Blower and be
confident that your equipment will run cooler. The Enclosure Blower
features a durable, lightweight polymer housing and fits in the bottom of
server cabinets where it draws cool air from beneath the floor and boosts
delivery of the coldest available air directly to server fronts. This unique
blower is the suggested solution for solid or partially vented front doors
with rails set back a minimum of four inches to establish the column of
air to raise to the top of the cabinet.
Benefits:
•Filterupto80%efficientfor2micronparticles,providingcleancool
air to your servers
•Improvesairdistributionreducingcabinethotspotsupto15°F,
extending server life and minimizing downtime
•Requiresonly2Uofmountingspace
•FitsanyEIA-310compliantcabinet
•5-yearlife
•Adjustableattachmentbracketsinstallseasily
•ULlisted
•Optionalfilterassemblyprovidescleanerair
Dual Power Transfer Switch
Rittal’s dual power transfer switch is designed to provide continuous
115VACpowerfortheenclosureblowerandothersinglecorded
fans and motor-driven devices. Capable of automatically switching
a 5A load during a power failure on one input circuit, the dual power
transfer switch can power other single corded fans and motor-driven
devices commonly deployed in data centers. With 5A re-settable
circuit breakers, the dual power transfer switch can easily handle the
largest fans currently used in data and server cabinets. Two differ-
ent colored 6' long power cords help ensure that power cable routing
won’t be a problem.
The dual power transfer switch can be mounted in the vertical zero
RMUspaceinsidethecabinetoronstandard19"railswithanoptional
1Upanel(notincluded).
While the switchover speed from the utility supply to battery/genera-
tor backup is more than fast enough for fans and other motor-driven
devices, the dual power relay is not intended for use with digital
equipment such as computers or equipment requiring a constant,
uninterrupted source of power.
TechnicalSpecifications:
•115VAC5Amax,50/60Hz
•Powercord6'each,5-15plug
•Re-settablecircuitbreakerforeachpowercord
•19"(482.6mm)rackmountwith1Upanel(notincluded)
•Maintainsoutputpowerfromtwoseparatepowersources
•1.25"Hx9.5"Wx2"D
1
3
2
Description Weight PartNo.
Enclosure blower w/attachment brackets
115VAC,0.65Amp,6'6"cord,5-15plug,250cfm
20 lbs shipped
14 lbs installed 9969.639
Filter assembly 2 lbs 9969.640
Replacement filters, 12 per box 5 lbs 9969.641
Dual power transfer switch 5 lbs 9969.658
1
2
3
RimatriX5 IT Solutions 57
Cooling
Rittal Enclosure Blower
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Roof Fan
Mounts easily into any enclosure roof.
Requires round cutout.
Material:
Fan housing of black painted sheet steel with
chrome plated finger guards.
Configuration:
Fan assembly; 10' power cord with plug; grounding
strap; installation hardware, 2 finger guards.
SplitRearDoorFan
With today’s high heat loads inside server enclosures,
it is critical to use thermal management techniques
with optimized enclosure ventilation. Having vented
front and rear doors and a vented roof, Rittal’s server
cabinets provide such ventilation. Rittal’s split rear
door fan takes advantage of the front to rear airflow of
most servers and allows the user to position the fan
assembly in the most critical location within the
cabinet. Two high pressure fans, 105 cfm each,
feature a shallow depth chassis design and
provide the ability to exhaust hot air out the rear of the
enclosure at a dramatically higher rate than traditional
roof mount fan trays. The result is cooler operating
equipment, even with very high enclosure heat loads.
Configuration:
•2fansperassembly(210cfmtotal)
•Includes10'cord/plug,mountinghardware
•Canbeusedforventingthroughroofbyinstalling
system bars/dual brackets (not included)
BlackcellsindicateRittalXpressproduct.
 Volts Totalcfm Cabinet Width Color PartNo.
(inches)
24" RAL 7035 light grey 9969.936
Black 9969.937
115 28" RAL 7035 light grey 9969.940
Black 9969.941
32" RAL 7035 light grey 9969.944
Black 9969.945
24" RAL 7035 light grey 9969.938
Black 9969.939
230 28" RAL 7035 light grey 9969.942
Black 9969.943
32" RAL 7035 light grey 9969.946
Black 9969.947
210
Protection Noise Rated Air Dimensions in Rated
rating level current displacement inches (mm) voltage Part No.
Diameter H V/Hz
 NEMA1 50dBa 0.4A 500cfm 9.1(232mm) 3.79"(96.40mm) 115/60 9964.163
 NEMA1 50dBa 0.4A 500cfm 9.1(232mm) 3.79"(96.40mm) 230/50/60 9961.868
Server Fan Assembly
With today’s high heat loads inside server enclosures,
it is critical to use thermal management techniques
which optimize enclosure ventilation. Having vented
front and rear doors and a vented roof, Rittal’s server
cabinets provide such ventilation. Rittal’s server fan
assembly takes advantage of the front-to-rear airflow
of most servers and allows the user to position the
fan assembly in the most critical location within
the cabinet.
The powerful 220 cfm high pressure fans feature a
shallow depth chassis design and provide the ability
to exhaust hot air out the rear of the enclosure at a
Cabinet width PartNo. Height Width Depth(1) cfm(2) Voltage Current Noise
RAL 7035
light grey Black in (mm) in (mm) in (mm)
24 9968.490 9968.493 11.73 (298) 19.49 (495) 2.56 (65) 440 115/50/60 0.72A 59 dB(A)
28 9968.491 9968.494 11.73 (298) 23.43 (595) 2.56 (65) 440 115/50/60 0.72A 59 dB(A)
32 9968.492 9968.495 11.73 (298) 27.36 (695) 2.56 (65) 440 115/50/60 0.72A 59 dB(A)
1) Depth of extension from enclosure door into enclosure
2) Free air delivery
dramatically higher rate than traditional roofmount fan
trays. The result is cooler operating equipment, even
with very high enclosure heat loads.
Configuration:
•2fansperassembly(440cfmtotal)
•Includes10'cord/plug,mountinghardware
•Optionalfanexpansiontototalof4fans
(220 cfm per fan)
*
* TE server cabinets only
58 RimatriX5 IT Solutions
Cooling
Fan Systems
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
TE Roof Fan
For active ventilation of the TE 7000, a ventilation
opening may be removed from the front of the
standard roof plate and fitted with the fan module.
The fan unit is pre-wired and ready for connection.
It has 2 fans, 1 thermostat and a connection cable
including IEC320 C14 connector. An additional
fan may optionally be integrated via an integral
terminal block.
Includes:
Fan unit, assembly parts, 2 fans, thermostat
and connection cable
TechnicalSpecificationsforOneFan:
See Fan Expansion Kit above
 Forenclosures Numberof Rated
W x D prewired operating Color PartNo.
inches (mm) fans voltage
115V RAL 7035 7000.920
All sizes 2 RAL 9005 7000.915
230V RAL7035 7000.670
TechnicalSpecificationsofThermostat:
Ratedoperatingvoltage:115Vor230V(210cfm)
Temperature range: 40°F to 131°F (+5°C to +55°C)
Accessories:
Fan expansion kit, see above.
FanExpansionKit
For retrofitting various fan units or to supplement the
fan mounting plate and fan roof, modular.
TechnicalSpecifications7980.000:
Ratedoperatingvoltage:230V
Powerconsumption:15/14Wat50/60Hz
Air displacement (unimpeded airflow): 94/106 cfm
(160/180 m3/h), 50/60 Hz
Noiselevel(unimpededairflow):37dB(A)
Temperature range: 14°F to 131°F (-10°C to +55°C)
TechnicalSpecifications7980.100:
Ratedoperatingvoltage:230V
Powerconsumption:14/12Wat50/60Hz
Air displacement (unimpeded airflow): 64/71 cfm
(108/120 m3/h), 50/60 Hz
Noiselevel(unimpededairflow):34dB(A)
Temperature range: -4°F to -94°F (-20°C to +70°C)
TechnicalSpecifications7980.148:
Ratedoperatingvoltage:48VDC
Powerconsumption:7.7W
Air throughput (unimpeded airflow): 108 cfm (184 m3/h)
Noiselevel(unimpededairflow):42dB(A)
Temperature range: -40°F to 158°F (–20°C to +70°C)
SupplyIncludes:
Fan, including assembly parts and connection
cable (24" [610 mm])
*For115V,inquire(7980.110)
Dimensions in inches (mm) Packsof PartNo.
4.69 x 4.69 x 1.50
(119 x 119 x 38) 1 set 7980.000
4.69 x 4.69 x 0.98
(119 x 119 x 25) 1 set 7980.100
4.69 x 4.69 x 0.98
(119 x 119 x 25) 1 set 7980.148
Cooling
Fan Systems
RimatriX5 IT Solutions 59
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DC Fan Mounting Plate
Exceptionallylow-noisethankstoFCSspeed
control, fully fitted
Suitable for TS8 enclosures with a raised roof (> 0.79 "
[20 mm]) or TS8 roof plate, vented. The fan mounting
plate may be used as an alternative to fan mounting
plate 7988.035. It is installed from above. A cable
entry is prepared in the rear section of the plate.
Benefits:
•Exceptionallylow-noiseduetospeedcontrol
•Allfansaremonitoredindividuallyforfailure
•HighairthroughputduetoDCtechnology
(unimpeded airflow 6 x 97 = 584 cfm
[6 x 165 = 990 m3/h])
•EMC-compatibleduetoDCfan
•Temperaturemonitoringandcontrol
•Highlevelofsafetyduetolow24VDCpowerpack
•Visualandacousticalarmmessages,plusrelay
alarm output
•FreelyselectableinstallationlocationfortheFCS
control unit (included with the supply of the fan
mounting plate, in 19" [482.6 mm] with 7320.440 or
on the frame with 7320.450)
•Suitableforinternationaluse,withawiderange
powerpack100–240VACandIEC320socket
•Fullypre-configured
•Network-compatibleviaCMC-TCprocessingunit
7320.100 (all relevant data such as temperature,
etc., is displayed in the web browser, or alarms
aresentintheformofanSNMPtrap)
TechnicalSpecifications:
Powerpackratedvoltage100–240VAC,50/60Hz
Powerpackratedcurrent:max.1.5A
Powerpacksecondaryrange:24VDC,3A
Temperature range: 41°F to 104°F (+5°C to +40°C)
Total air throughput (unimpeded airflow):
6 x 97 = 584 cfm (6 x 165 = 990 m3/h)
Protection Category:
IP40
TechnicalSpecificationsforOneFan:
Ratedvoltage:24VDC
Rated current: max. 0.28 A
Rated output: max. 6.72 W
Air throughput (unimpeded airflow): 97 cfm (165 m3/h)
Speed: 2650 rpm
Noiselevel:upto41.0dB(A)
at maximum speed activation
Also Required:
Connectioncable230/115V
Example,USversion,PartNo.7200.214
Accessories:
1Umountingunit,PartNo.7320.440
Mountingmodule,PartNo.7320.450
For For NumberofPart
enclosures enclosures DC fans No.
Width in (mm) Depth in (mm)
32 (800)
36 (900)
32 (800) 40 (1000) 6 7858.488
42 (1050)
48 (1200)
60 RimatriX5 IT Solutions
Cooling
Fan Systems
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
With nano-coated condenser.
Note:
Integration of the air conditioners
with comfort controller, into a
superordinate remote monitoring
system, can be achieved with an
optional interface board 3124.200
(RS 232, RS 485, RS 422 and
PLCinterface).
Partial Internal Mounting
Possible With 3303.XXXOnly.
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
PropertyRights:
USdesignpatentno.D488,480
IR reg. design no. DM/061 967
with validity for FR, IT, ES
Germanregistereddesigns
no. 402 02 324 and no. 402 02 325
Japanese registered design
no. 1 187 896
Indian registered design
no. 189 953
T2
42
550
T
280
100
100
1
PartNo.withbasiccontroller,RAL7035lightgrey 3302.100 3302.110 3303.100 3303.110
PartNo.withcomfortcontroller,RAL7035lightgrey 3303.500 3303.510
VoltageV,Hz 230, 50/60 115, 60 230, 50/60 115, 60
Dimensions in inches (mm) Height (H) 22 (550) 22 (550)
Width (B) 11 (280) 11 (280)
Depth (T) 6 (140) 8 (200)
T2 4 (98) 6 (158)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 864 (253) 2400 (703)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 1025/1093 (300/320) 1708/2083 (500/610)
L 95 L 122 512/581 (150/170) 957/1195 (280/350)
Rated current maximum 1.6 A/1.7 A 3.3 A 2.6 A/2.6 A 5.7 A
Starting current 3.0 A/3.4 A 8.0 A 5.1 A/6.4 A 11.5 A
Pre-fuseT 10.0 A/10.0 A 10.0 A 10.0 A/10.0 A 10.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 245 W/255 W 290 W 360 W/380 W 470 W
L 35 L 50 255 W/275 W 340 W 420 W/390 W 500 W
Cooling coefficient j =QK/Pel L 35 L 35 1.2 1.4
Refrigerant R134a, 3.5 oz (100 g) R134a, 6.0 oz (170 g)
Maximum allowable operating pressure 263 psi (25 bar) 406 psi (28 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C)
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 28.7 (13) 37.5 (17)
Air displacement of fans External circuit 182 cfm (310 m3/h) 203 cfm (345 m3/h)
Internal circuit 203 cfm (345 m3/h) 182 cfm (310 m3/h)
Temperature control Basic or comfort controller (factory setting 95°F [+35°C])
Accessories PU
Filter mats 3 3286.300
Metal filters 1 3286.310
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Condensate hose 1 3301.608 3301.610
Special voltages available on request. Technical modifications reserved.
BlackcellsindicateRittalXpressproduct.
RimatriX5 IT Solutions 61
Wallmounted Air Conditioners
Usefulcoolingcapacity1093/2080BTU(320/610W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
With nano-coated condenser and
integrated condensate evaporator.
Note:
Integration of the air conditioner
with comfort controller, into a
superordinate remote monitoring
system, can be achieved with
an optional interface board
3124.200 (RS 232, RS 485,
RS422andPLCinterface).
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
PropertyRights:
Germanregistereddesign
no. 402 02 325
IR reg. design no. DM/062 557
with validity for FR, IT, ES
Indian registered design
no. 190 269
Japanese registered design
no. 1 187 905
105
155
210
50
950
260
400
PartNo.withbasiccontroller,RAL7035lightgrey 3304.100 3304.110 3305.100 3305.110
PartNo.withcomfortcontroller,RAL7035lightgrey 3304.500 3304.510 3305.500 3305.510
VoltageV,Hz 230, 50/60 115 1), 50/60 230, 50/60 115 1), 50/60
Dimensions in inches (mm) H 37 (950) 37 (950)
W 16 (400) 16 (400)
D 10 (260) 10 (260)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 3916 (1147) 5794 (1697)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 3415/3620 (1000/1060) 5123/5157 (1500/1510)
L 95 L 122 2698/2869 (790/840) 4201/4269 (1230/1250)
Rated current maximum 4.8 A/4.4 A 9.5 A/10.0 A 5.4 A/6.0 A 11.0 A/12.5 A
Starting current 12.0 A/14.0 A 26.0 A/28.0 A 22.0 A/24.0 A 42.0 A/46.0 A
Pre-fuseT 10.0 A/10.0 A 16.0 A/16.0 A 16.0 A/16.0 A 20.0 A/20.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 700 W/650 W 725 W/680 W 850 W/1000 W 880 W/1050 W
L 35 L 50 750 W/710 W 780 W/750 W 1000 W/1160 W 1040 W/1200 W
Cooling coefficient j =QK/Pel L 35 L 35 1.4 1.8 1.7
Refrigerant R134a, 17.6 oz (500 g) R134a, 21.2 oz (600 g)
Maximum allowable operating pressure 363 psi (25 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C )
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 86.0 (39) 97.0 (44) 90.3 (41) 101.4 (46)
Air displacement of fans External circuit 530 cfm (900 m3/h)
Internal circuit 353 cfm (600 m3/h) 471 cfm (800 m3/h)
Temperature control Basic or comfort controller (factory setting +95°F [35°C])
Accessories PU
Filter mats 3 3286.400
Metal filters 1 3286.410
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Condensate hose 1 3301.612
1) Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
BlackcellsindicateRittalXpressproduct.
62 RimatriX5 IT Solutions
Wallmounted Air Conditioners
Usefulcoolingcapacity3620/5150BTU(1060/1510W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Configuration:
Fully wired ready for connection,
including drilling template, eyebolt
and assembly parts.
With nano-coated condenser and
integrated condensate evaporator.
Note:
Integration of the air conditioners
with comfort controller, into a
superordinate remote monitoring
system, can be achieved with
an optional interface board
SK 3124.200 (RS 232, RS 485,
RS422andPLCinterface).
Additional Parts Needed:
For installation in the door,
the use of a ride-up roller is
recommended.
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
400
40
1580
295
145
150
245
50
PartNo.withbasiccontroller,RAL7035lightgrey 3328.100 3328.110 3329.100 3329.110
PartNo.withcomfortcontroller,RAL7035lightgrey 3328.500 3328.510 3329.500 3329.510
VoltageV,Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60
Dimensions in inches (mm) H 62 (1580) 62 (1580)
W 16 (400) 16 (400)
D 11 (290) 11 (290)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 8706 (2550) 10525 (3083)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 6830/8026 (2000/2350) 8537/9392 (2500/2750)
L 95 L 122 4952/6771 (1450/1690) 5464/5977 (1600/1750)
Rated current maximum 6.9 A/8.5 A 13.6 A/16.2 A 8.0 A/10.0 A 16.0 A/21.0 A
Starting current 22.0 A/26.0 A 36.0 A/39.0 A 21.0 A/21.0 A 44.0 A/42.0 A
Pre-fuseT 16.0 A/16.0 A 25.0 A/25.0 A 16.0 A/16.0 A 25.0 A/25.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 900 W/1070 W 960 W/1130 W 1320 W/1550 W 1380 W/1600 W
L 35 L 50 1130 W/1220 W 1170 W/1290 W 1500 W/1880 W 1550 W/1940 W
Cooling coefficient j=QK/Pel L 35 L 35 1.7 1.9
Refrigerant R134a, 33.5 oz (950 g)
Maximum allowable operating pressure 406 psi (28 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C)
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 145.5 (66) 160.9 (73) 152.1 (69) 167.6 (76)
Air displacement of fans External circuit 377 cfm (640 m3/h) 418 cfm (710 m3/h)
Internal circuit 324 cfm (550 m3/h) 377 cfm (640 m3/h)
Temperature control Basic or comfort controller (factory setting 95°F [+35°C])
Accessories PU
Filter mats 3 3286.400
Metal filters 1 3286.410
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Condensate hose 1 3301.612
1) Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
BluecellsindicateAitems.
RimatriX5 IT Solutions 63
Wallmounted Air Conditioners
Usefulcoolingcapacity8026/9392BTU(2350/2750W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Designed For
OfficeApplications.
Low noise level (considerably
quieter than air conditioners for
industrial applications). With nano-
coated condenser and integrated
condensate evaporator.
Configuration:
Fully wired ready for connection,
including automatic condensate
evaporation, drilling template and
assembly parts.
With nano-coated condenser and
integrated condensate evaporator.
Note:
Integration of the air conditioners
with comfort controller, into a
superordinate remote monitoring
system, can be achieved with
an optional interface board
3124.200 (RS 232, RS 485,
RS422andPLCinterface).
Accessories:
Roof plate for TS8 modular
enclosures with mounting cutout.
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
PropertyRights:
Germanregistereddesign
no. 402 02 324
Germanregistereddesign
no. 402 02 325
375
597
415
475
260
PartNo.withcomfortcontroller 3273.500 3273.5151)
Voltage V, Hz 230, 50/60 115, 50/60
Dimensions in inches (mm) H x W x D 16 x 24 x 19 (415 x 597 x 475)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 4687 (1373)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 3756/4098 (1100/1200)
L 95 L 122 2903/2971 (850/870)
Rated current maximum 5.2 A/5.4 A 11.0 A/11.5 A
Starting current 15.5 A/16.5 A 32.0 A/35.0 A
Pre-fuseT 10.0 A/10.0 A 20.0 A/20.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 890 W/910 W 920 W/940 W
L 35 L 50 960 W/1100 W 990 W/1140 W
Cooling coefficient j=QK/Pel L 35 L 35 1.2
Refrigerant R134a, 24.7 oz (700 g)
Maximum allowable operating pressure 363 psi (25 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C)
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 92.6 (42) 103.6 (47)
Color RAL 7035 light grey
Air displacement of fans External circuit 1036 cfm (1760 m3/h)
Internal circuit 259 cfm (440 m3/h)
Temperature control Basic or comfort controller (factory setting 95°F [+35°C])
Accessories PU
Filter mats 3 3286.100
Metal filters 1 3286.210
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Air ducting system 1 3286.870
Cover stoppers for interior air outlet 2 3286.980
Condensate hose 1 3301.612
1) Delivery times on request.
Special voltages available on request. We reserve the right to make technical modifications.
64 RimatriX5 IT Solutions
Roofmounted Air Conditioners
Usefulcoolingcapacity4098BTU(1200W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
With nano-coated condenser and
integrated condensate evaporator.
Note:
Air conditioners with comfort
controller may be integrated into a
superordinate remote monitoring
system with an optional interface
board 3124.200 (RS 232, RS 485,
RS422andPLCinterface).
Accessories:
Roof plate for TS8 modular
enclosure with mounting cutout.
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
PartNo.withbasiccontroller,RAL7035lightgrey 3382.100 3382.110 3359.100 3359.110
PartNo.withcomfortcontroller,RAL7035lightgrey 3382.500 3382.510 3359.500 3359.510
VoltageV,Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60
Dimensions in inches (mm) H x W x D 16 x 24 x 15 (415 x 597 x 375)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 1581 (463) 3081 (903)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 1708/1742 (500/510) 2561/2766 (750/810)
L 95 L 122 922/1264 (270/370) 1861/2015 (545/590)
Rated current maximum 2.7 A/2.9 A 5.5 A/6.0 A 3.0 A/3.9 A 6.0 A/7.8 A
Starting current 9.2 A/10.2 A 18.4 A/18.4 A 10.0 A/10.7 A 20.0 A/21.4 A
Pre-fuseT 10.0 A/10.0 A 10.0 A/10.0 A 10.0 A/10.0 A 16.0 A/16.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 360 W/410 W 370 W/420 W 410 W/520 W 420 W/535 W
L 35 L 50 410 W/450 W 420 W/470 W 490 W/600 W 500 W/615 W
Cooling coefficient j=QK/Pel L 35 L 35 1.4 1.8
Refrigerant R134a, 8.8 oz (250 g) R134a, 10.6 oz (300 g)
Maximum allowable operating pressure 363 psi (25 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C)
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 66.1 (30) 77.1 (35) 70.5 (32) 81.5 (37)
Air displacement of fans (unimpeded airflow) External circuit 536 cfm (910 m3/h)
Internal circuit 259 cfm (440 m3/h)
Temperature control Basic or comfort controller (factory setting 95°F [+35°C])
Accessories PU
Filter mats 3 3286.500
Metal filters 1 3286.510
Quick-change frame 1 3286.700
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Air ducting system 1 3286.870
Cover stoppers for interior air outlet 2 3286.780
Condensate hose 1 3301.612
Special voltages available on request. Technical modifications reserved.
475
597
415
490
390
Propertyrights:
Germanregistereddesign
no. 402 02 324
Germanregistereddesign
no. 402 02 325
BluecellsindicateAitems.
RimatriX5 IT Solutions 65
Roofmounted Air Conditioners
Usefulcoolingcapacity1742/2766BTU(510/810W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
With nano-coated condenser and
integrated condensate evaporator.
Note:
Integration of the air conditioners
with comfort controller, into a
superordinate remote monitoring
system, can be achieved with
an optional interface board
3124.200 (RS 232, RS 485,
RS422andPLCinterface).
Accessories:
Roof plate for TS8 modular
enclosure with mounting cutout.
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
PropertyRights:
Germanregistereddesign
no. 402 02 324
Germanregistereddesign
no. 402 02 325
475
597
415
490
390
PartNo.withbasiccontroller,RAL7035lightgrey 3383.100 3383.110
PartNo.withcomfortcontroller,RAL7035lightgrey 3383.500 3383.510
VoltageV,Hz 230, 50/60 115, 50/60
Dimensions in inches (mm) H x W x D 16 x 24 x 19 (415 x 597 x 475)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 4462 (1307)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 3415/3688 (1000/1080)
L 95 L 122 2596/2800 (760/820)
Rated current maximum 4.3 A/4.5 A 8.3 A/8.7 A
Starting current 15.5 A/15.5 A 25.3 A/24.3 A
Pre-fuseT 10.0 A/10.0 A 16.0 A/16.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 550 W/650 W 580 W/660 W
L 35 L 50 660 W/750 W 670 W/755 W
Cooling coefficient j=QK/Pel L 35 L 35 1.8
Refrigerant R134a, 17.6 oz (500 g)
Maximum allowable operating pressure 363 psi (25 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C)
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 88.2 (40) 101.4 (46)
Air displacement of fans External circuit 1036 cfm (1760 m3/h)
Internal circuit 259 cfm (440 m3/h)
Temperature control Basic or comfort controller (factory setting 95°F [+35°C])
Accessories PU
Filter mats 3 3286.500
Metal filters 1 3286.510
Quick-change frame 1 3286.800
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Air ducting system 1 3286.870
Cover stoppers for interior air outlet 2 3286.880
Condensate hose 1 3301.612
Special voltages available on request. Technical modifications reserved.
BluecellsindicateAitems.
66 RimatriX5 IT Solutions
Roofmounted Air Conditioners
Usefulcoolingcapacity3688BTU(1080W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
With nano-coated condenser and
integrated condensate evaporator.
Note:
Integration of the air conditioners
with comfort controller, into a
superordinate remote monitoring
system, can be achieved with
an optional interface board
3124.200 (RS 232, RS 485,
RS422andPLCinterface).
Accessories:
Roof plate for TS8 modular
enclosure with mounting cutout.
Certifications:
UL,cUL,CSA
ULfile:ACVS2.SA8250
Detailed Drawing:
visit: www.rittal-corp.com
Performance Diagrams:
visit: www.rittal-corp.com
PropertyRights:
Germanregistereddesign
no. 402 02 324
Germanregistereddesign
no. 402 02 325
475
597
415
490
390
PartNo.withbasiccontroller,RAL7035lightgrey 3384.100 3384.110 3385.100 3385.110
PartNo.withcomfortcontroller,RAL7035lightgrey 3384.500 3384.510 3385.500 3385.510
VoltageV,Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60
Dimensions in inches (mm) H x W x D 16 x 24 x 19 (415 x 597 x 475) 16 x 24 x 19 (415 x 597 x 475)
UsefulcoolingcapacityQKinBTU(W) L 131 L 131 6009 (1760) 8272 (2423)
Usefulcoolingcapacity
QKtoDIN3168inBTU(W)
L 95 L 95 5123/5191 (1500/1520) 6830/7274 (2000/2130)
L 95 L 122 3757/4132 (1100/1210) 5362/5703 (1570/1670)
Rated current maximum 5.7 A/6.8 A 12.5 A/14.1 A 5.7 A/6.6 A 13.0 A/14.2 A
Starting current 16.6 A/17.1 A 30.7 A/29.1 A 16.8 A/18.4 A 36.0 A/32.0 A
Pre-fuseT 10.0 A/10.0 A 20.0 A/20.0 A 10.0 A/10.0 A 20.0 A/20.0 A
PowerconsumptionPeltoDIN3168 L 35 L 35 815 W/930 W 850 W/950 W 1000 W/1175 W 1050 W/1250 W
L 35 L 50 950 W/1090 W 1000 W/1150 W 1100 W/1310 W 1160 W/1380 W
Cooling coefficient j=QK/Pel L 35 L 35 1.8 2.0
Refrigerant R134a, 17.6 oz (500 g)
Maximum allowable operating pressure 363 psi (25 bar)
Temperature and setting range 68°F to 131°F (+20°C to +55°C)
RatingstoEN60529/10.91 External circuit UL(IP34)
Internal circuit UL12(IP54)
Duty cycle 100%
Type of connection Plug-interminalstrip
Weight in lb (kg) 90.3 (41) 103.6 (47) 92.6 (42) 105.8 (48)
Air displacement of fans External circuit 1036 cfm (1760 m3/h) 1071 cfm (1820 m3/h)
Internal circuit 277 cfm (470 m3/h)
Temperature control Basic or comfort controller (factory setting 95°F [+35°C])
Accessories PU
Filter mats 3 3286.500
Metal filters 1 3286.510
Quick-change frame 1 3286.800
Door-operated switch 1 4127.000
SK bus system for comfort controller 1 3124.100
RiDiag II including cables for comfort controller 1 3159.100
Interface card for comfort controller 1 3124.200
Air ducting system 1 3286.870
Cover stoppers for interior air outlet 2 3286.880
Condensate hose 1 3301.612
Special voltages available on request. We reserve the right to make technical modifications.
BluecellsindicateAitems.
RimatriX5 IT Solutions 67
Roofmounted Air Conditioners
Usefulcoolingcapacity5191/7274BTU(1520/2130W)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
Rated operating voltage PartNo.
 230VAC 3120.000
 115VAC 3120.1151)
1) Delivery times available on request.
Accessories
PartNo.
Mounting adapter 7526.964
FanSpeedControl
Temperature dependent speed control for Rittal fan
and filter units and air/air heat exchangers with a
ratedoperatingvoltageof230VACfornoise
reduction and to save energy in part-load operation.
TechnicalSpecifications:
•Formountingona1.38"(35mm)supportrail
DINEN50022
•Dimensions(HxWxD):2.24x3.70x7.09"
(57 x 94 x 180 mm)
•Ratedoperatingvoltage:230VAC/115VAC
•Settingrange:68°Fto131°F(+20°Cto+55°C)
•Phasecross-overwithmicrocontroller
•Maximumfanoutput250Wor1.2Aat230VAC
•Maximumfanoutput100Wor1.2Aat115VAC
SupplyIncludes:
SpeedcontrolbuiltintoaPKenclosure9512100,
temperature sensor length 5.90' (1.80 m)
Interface Board
ForTopThermCoolingUnitswithComfort
Controller for connecting to the CMC-TC
monitoringsystemProcessingUnitII(PUII).
The interface board is an extension for TopTherm
cooling units with a comfort controller. In this way it
is possible to monitor a master/slave combination
of up to 10 cooling units. Control is achieved by
standardized interfaces: RS 232 (DB9) or RS 485,
onePLCinterface(DB9).RS422(RJ45jack)isthe
connection to the Rittal CMC-TC. Remote space mon-
itoringbyTCP-IP,graphicalinterfacesforoperation,
evaluation and control, documentation, connection to
additional sensors for access control, monitoring is
therefore possible.
 Packsof PartNo.
1 3124.200
MountingAdapter
Theextensioncardisbuiltintoa1Uplastichousing.
Avoltagesupplyof24VDCisneeded.Thismaybe
supplied from the CMC-TC by a wide-range power
pack(PartNo.7320.425)100to240VAC,50/60Hz
or externally by a Kycon connector.
SupplyIncludes:
Interface board integrated into a plastic box
HXWxD(inches):1.73(1U)x5.35x5.00
(44 x 136 x 129 mm)
PU PartNo.
13110.200
Bottom-MountedAdapter
Forenclosureinternalthermostat3110.000
andhygrostat3118.000
Bottom-mounted adapter with mounting option for
screwed cable glands, for targeted cable infeed from
appropriate equipment such as filter fan units and
enclosure heaters. In conjunction with screwed cable
glands, it is also suitable for use as strain relief.
68 RimatriX5 IT Solutions
Cooling
Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CoolingCooling
Voltage PartNo.
230/115/60/48/24V(AC) 3110.000
60/48/24V(DC)
Voltage PartNo.
24-230V(AC/DC) 3118.000
Enclosure Internal Thermostat
Ideal for controlling filter fan units, heaters and heat
exchangers, this thermostat can also be used as a
signal generator for monitoring the enclosure internal
temperature.
TechnicalSpecifications:
•Bi-metalsensorasatemperature-sensitiveelement
with thermal feedback
•Contactpopulation:Single-polechange-over
contact as a quick-break contact
•Permissiblecontactload:
Category 5 – 3 (heating)
AC 10 (4)1) A,
DC = 30 W
Category 5 – 4 (cooling)
AC 5 (4)1) A,
DC = 30 W
(1) = Inductive load at cos j = 0.6
•Settingrange40°Fto140°F(+5°Cto+60°C)
•Weightapproximately3.7oz(105g)
•Dimensions2.80x2.80x1.30"(71x71x33mm)
•Switchingdifferenceapproximately1K±0.8K
•Abroadvoltagespectrum,justonemodelcovers
24to230V
•Time-savingconnectiontechniqueusingaterminal
strip with a screw connection from the outside
•Flexiblemountingonaverticalorhorizontal1.38"
(35mm)supportrailtoEN50022,andsnap
fastening in the TS/ES enclosure section using
the supplied adapter
Hygrostat
The hygrostat switches on the heater and/or fan
when a preset relative humidity level in the enclosure
is exceeded. The relative humidity is raised above the
dew point, and condensation on assemblies or
electronic components is avoided.
TechnicalSpecifications:
•Contactpopulation:Single-polechange-over
contact as a quick-break contact
•Permissiblecontactload:
AC ~ 5 (0.2)1) A
DC = maximum 20 W
(1) = Inductive load at cos j = 0.6
•Settingrange50–100%relativehumidity
•Weightapproximately3.5oz(100g)
•Dimensions2.80x2.80x1.30"(71x71x33mm)
•Switchingdifferenceapproximately4%
•Abroadvoltagespectrum,justonemodelcovers
24to230V
•Time-savingconnectiontechniqueusingaterminal
strip with a screw connection from the outside
•Flexiblemountingonaverticalorhorizontal1.38"
(35mm)supportrailtoEN50022,andsnap
fastening in the TS/ES enclosure section using
the supplied adapter
RimatriX5 IT Solutions 69
Cooling
Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
For Filter Fan Units HxWxDinches(mm) PU PartNo.
3321. . . . 4 x 4 x 0.4 (89 x 89 x 10) 5 3321.700
3322. . . . 5 x 5 x 1 (120 x 120 x 12) 5 3322.700
3323. . . . 7 x 7 x 1 (173 x 173 x 17) 5 3171.100
3324. . . ./ 3325. . . . 9 x 9 x 1 (221 x 221 x 17) 5 3172.100
3326. . . . 11 x 11 x 1 (289 x 289 x 17) 5 3173.100
3327. . . . 11 x 11 x 0.4 (289 x 289 x 10) 5 3327.700
For Filter Holders HxWxDinches(mm) PU PartNo.
3175.000 10 x 13 x 1 (242 x 338 x 20) 3 3174.000
SpareFilterMatsforFilterFans
Madeofchopped-fibermatwithaprogressive
structure.
Temperature resistant to 212°F (100°C),
self-extinguishingcategoryF1toDIN53438.
Dust-laden air side: Open structure.
Clean air end: Closed structure.
Reliable filtering of virtually all types of dust from
a particle size of 10 μm.
For Filter Fan Units/Outlet Filters HxWxDinches(mm) PU PartNo.
3323 . . . . 7 x 7 x 1 (173 x 173 x 12) 5 3181.100
3324 . . . ./3325 . . . . 9 x 9 x 0.4 (221 x 221 x 12) 5 3182.100
3326. . . ./3327. . . . 11 x 11 x 1 (289 x 289 x 12) 5 3183.100
Fine Filter Mats for Filter Fans
Madeofchopped-fibermatwithaprogressive
structure.
Temperature-resistant to 100°C (212°F),
self-extinguishingcategoryF1toDIN53438.
Dust-laden air side: Open structure.
Clean air end: Closed structure.
Reliable filtering of virtually all types of dust
from a particle size of 10 μm.
Material:
Chemical fiber
Material:
Chemical fiber
70 RimatriX5 IT Solutions
Cooling
Accessories
Filter Mats for Air Conditioners
Rittal air conditioners are low-maintenance and are
supplied without filter mats. Filter mats my be used
for extreme conditions.
ForTopThermAirConditioners
For Air Conditioner HxWxDinches(mm) PU PartNo.
3302.300 / 3302.310 3.7 x 7.5 x 0.4 (95 x 190 x 10) 1 3286.110
3302.100 / 3302.110 / 3303. . . ./ 3361. . . . 7.9 x 10.4 x 0.4 (200 x 265 x 10) 1 3286.300
3304. . . ./ 3305. . . ./ 3328. . . ./ 3329. . . ./ 3332. . . ./
3366. . . . 11.3 x 13.5 x 0.4 (288 x 344 x 10) 1 3286.400
3273. . . ./ 3382. . . ./ 3383. . . ./ 3384. . . ./ 3385. . . ./
3359. . . . 10.0 x 20.9 x 0.4 (255 x 530 x 10) 1 3286.500
3386. . . ./ 3387. . . . 11.8 x 28.3 x 0.4 (300 x 720 x 10) 1 3286.600
3377. . . . 8.3 x 8.1 x 0.4 (210 x 205 x 10) 1 3253.010
Material:
Open celled polyurethane foamed plastic with excel-
lent physical and mechanical properties. Temperature
resistant from -40°F to 176°F (-40°C to +80°C).
Thickness: 0.39" (10 mm).
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cooling
RimatriX5 IT Solutions 71
Cooling
Accessories
For Air Conditioner PU PartNo.
Air Duct System
3382. . . ./3383. . . ./3384. . . ./3385. . . ./ 3273. . . . /3359. . . . 1 3286.870
3386. . . ./3387. . . . 1 3286.970
Air Duct System
ForTopThermRoofmountedAirConditioners
The air duct system for Rittal TopTherm roofmounted
air conditioners makes it possible to route the cold
air directly to specific areas of the enclosure. The
risk of short circuits in the air circulation due to
self-ventilated installed devices is eliminated.
The length of the flat duct is 59" (1500 mm), and
it may be cut to the desired length.
Note:
Do not direct cold air straight at active components.
When using the ducting system, the performance of
the air conditioner may be reduced, depending on
the application in question.
Material:
Flame-resistantplastictoDIN4102/B1.
Configuration:
Flat duct, compensating hose.
Accessories:
90° deflector, see www.rittal-corp.com.
Cover bungs, see www.rittal-corp.com.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
72 RimatriX5 IT Solutions
Monitoring and Security
RimatriX5 IT Solutions from Rittal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
The Basic System
CMC-TCMasterUnitII ..................................................................................................................... 75
ProcessingUnitII ............................................................................................................................. 76
SensorUnits ..................................................................................................................................... 77
Additional Units .............................................................................................................................. 81
Cable and Mounting Accessories ................................................................................................. 82
Internal Security Accessories ....................................................................................................... 85
Access Systems Accessories ....................................................................................................... 91
Monitoring of Climate Control Units ............................................................................................ 96
ControlConsoleDrawer,OptionalKVM ....................................................................................... 97
Remote Monitoring Software ........................................................................................................ 98
The physical security of your IT enclosures is one of the essential factors
contributing to the high availability of a whole IT infrastructure. Temperature, smoke
and vibration sensors, together with sophisticated access control solutions, provide
reliable protection against external influences.
And this is exactly how the Rittal CMC-TC works, at all the relevant points within
your company. Computer Multi Control-Top Concept – The tailor-made complete
system with modules for your IT security. A guarantee of maximum availability,
enhanced productivity and complete transparency.
UsetheRittalCMC-TCtoensurecomprehensiveITsecurity,process
optimizationofyourproductionandpioneeringbuildingmanagement(SNMP
protocol). Rittal CMC-TC – Security management has never been so individual,
easy and cost-effective.
RimatriX5 IT Solutions 73
Monitoring and Security
RimatriX5 IT Solutions from Rittal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
TheProcessingUnitII(PUII)isthe
basis of any CMC-TC application.
Connectivity is offered by the
networkinterface(10BaseT,TCP/
IP,SNMP)whichconnectsdirectly
into the user network or to the
CMC-TC Master II. The following
products are required for each
CMC-TC application:
Connection Tables
PowerPack Connection Programming Connection MountingUnit Interference
Required Accessories Cable Cable Cable, Mounting Suppression
24VDC  SensorUnit Module Capacitor
7320.425 7200.210 7200.221 7320.470 7320.440 7200.490
7320.435 7200.211 7320.472 7320.450
PartNo. 7200.213  7320.475
7200.214  7320.481
7200.215 7320.485
7320.005 MasterUnitII(optional) • •
7320.105 ProcessingUnitII • • •
7320.215 I/Ounit(sensorunit) •
7320.225 Accessunit(sensorunit) •
7320.235 Climateunit(sensorunit) • •
7320.815 Fancontrolsystem(sensorunit) •  •
7320.605/7320.615 VoltagemonitorwithIECjack •   
7320.705 Electromagnetic Ergoform-S handle
forFR,PS,TCandTE     
7320.735 Universallatch     
7320.755 Smartcard reader
7320.765 Magnetic card reader
7320.775 Coded lock
7200.635 CMC socket strip
7200.525 Voltageexpansionunit •max.2x  •max.1x 
2372.005 CMC alarm signal lamp
Adapter for Connection Extension Locking Bar Attachment Digital Sensor
Required Accessories ReaderUnits Cable Cable PS/FR forUniversal Input Module
RJ 10/12 RJ 10/12 Lock
7200.344 7200.420 7200.440 7200.371 7200.61X 7320.580
PartNo. 7200.345 7200.430 7200.450 7200.372
7200.346 7320.814
7200.347
7320.005 MasterUnitII    
7320.105 ProcessingUnitII     
7320.215 I/O unit RJ 12 •1)
7320.225 Access unit RJ 12 •1)
7320.235 Climate unit RJ 12 •1)
7320.815 Fan control system (sensor unit)
7320.605/7320.615 VoltagemonitorwithIECjack    
7320.700 Electromagnetic Ergoform-S handle
  forFR,PS,TCandTE
7320.735 Universallatch    
7320.755 Smartcardreader •    
7320.765 Magneticcardreader •    
7320.775 Codedlock •    
7200.635 CMCsocketstrip RJ10• RJ10  •
7200.525 Voltageexpansionunit    
2372.005 CMCalarmsignallamp RJ12• RJ12
= Optional accessories
•=Requiredaccessories 
1) = In conjunction with CMC-TC accessories (sensors/actuators/handles/readers) type RJ 12
Processing Unit II (PU II)
(7320.100)
Programming Cable (7200.221)
Power Pack 100–240V
50 – 60 Hz (7320.425) or power
pack48VDC(7320.435)
Cable for Power pack,
country-specific
(7200.210 – 215)
Connection Cable, Sensor Unit
(7320.470 / 472 / 475 / 481 / 485)
UptoFourSensorUnits,
But at Least One
(7320.210 / 220 / 230 / 810)
1
1
74 RimatriX5 IT Solutions
Monitoring and Security
The Basic System
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Camera available on request.
Monitoring System CMC-TC
Master II
Benefits:
•Centralizedadministration
•Networkconnection10/100BaseT
•Centralwebserverforconfiguration
•LocaladministrationviaconsoleVGA/PS/2
•Loggingfunctionforalarmmessages
•LinkforUSBwebcamera
•Freefunctionselectionformonitoring
•Idealforlargedatacenters
•WebaccessviaSSL3.0128bitencryption
•RemoteadministrationviaSSH
•Monitoringfunctionsmaybelinkedtogether
•E-mailfunctionviaSMTP
•VideomonitoringmaybelinkedtotheCMC-TC
monitoring functions
The CMC-TC Master II is an optional component in
the CMC-TC system. The master allows the alarm
dataofupto10PUIIsystemstobelinkedand
displayed. Special features of this system include its
superiorflexibilityandperformance.Upto10PUII
systems may be distributed directly in the customer’s
intranet.LikethePUII,theMasterIIcanbeplacedat
any position within the network.
Usersmaydirectlyaccessthewebpagesofthe
PUIIorthewebpageoftheMasterII,whereall
dataiscombinedandlinked.ThePUIItransmits
all monitoring-related data and messages to the
mastersystemviaTCP/IP,SNMP.Themasterunit
has a 10BaseT/100BaseT network interface for net-
work integration. All monitoring data is provided in
aseparateMIBviaTCP/IP,SNMP.Thesystemmay
be configured remotely via the integral web server.
Basic settings can also be implemented serially
via RS232 or Telnet. A Telnet routing function to the
individualProcessingUnitsIIisalsopre-integrated,
providing users with a clear central monitoring facility.
For example, up to 160 temperature sensors may be
accessed or up to 80 enclosure doors may be moni-
toredandactivatedviaoneIPaddress.Combined
applications are also possible, and may be compiled
individuallyfromPUIIandsensorunits.Functional
upgrades for the CMC-TC Master II are available on
request in the form of a software update. Images may
be archived on the hard drive via an optional web
camera.UptotwoUSBcamerasmaybeconnected.
USBwebcamavailableonrequest.
PartNo. 7320.005
Networkinterface Ethernet to IEEE 802.3 via
10BaseT/100BaseT, 10/100 Mbit/s
Protocols TCP/IP,SNMPV1.0,TELNET,SSH,
TFTP,HTTPS
Rated voltage 100–240VACAC,50/60Hz
Serial interfaces 2D-SUB9jacksRS232
USB Standard2.0forRittalUSBwebcams
Time function Real-time clock
Temperature
application range 41°F to 95°F (+5°C to +35°C)
Humidity applica-
tion range 5% to 80% relative humidity,
non-condensing
Also Required:
A component shelf must also be ordered for
each CMC-TC Master II.
Master II
ProcessingUnitII(PUII)
Sensor unit
1
1
LAN
RimatriX5 IT Solutions 75
Monitoring and Security
OptionalBasicModule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Monitoring System
Processing Unit II
The processing unit forms the basis of the CMC-TC
system. This unit is required for every monitoring
application.
Benefits:
•Selectablemonitoringfunctions
•Sensor/actuatorportsextendible
•TCP/IPSNMPnetworkconnection
•Integralwebserverforconfiguration
•Automaticmenugeneration
•Simpleinstallationbasedonthe
plug-and-play system
•Alarmcontinuestorecordevenintheeventofa
network failure
•Built-inreal-timeclock
•Maybeusedviapowerpackfor115/230VACor
48VDC
•Choiceofmountingontheenclosureframeor
19" (482.6 mm) mounting angles
•Theprotocolforthemaster/slavesystemis
TCP/IPSNMP
•Maybeusedforlargedatacentersorsmall
individual applications
 PartNo. 7320.100
 HxWxDin(mm) 1.73x5.35x5.08"(44[1U]x136x129)
 Networkinterface EthernettoIEEE802.3
via 10/100BaseT full-duplex
10/100 Mbit/s
 Protocols TCP/IP,SNMPV1.0,TELNET,FTP,
  HTTP,SSM,NTP,DHCP,PPP
 Ratedvoltage 24VDC
Serial interface RS 232
 Portsfor 4 jacks RJ 45, shielded
sensor units
Bus system Power12C for extension unit voltage
AC 7200520
 Alarmrelay Change-overcontactmax.24VDC
output 1 A
 Audiodisplay Piezosignalgenerator
Time function Real-time clock
Temperature 41°F to 113°F (+5°C to +45°C)
application range
Humidity 5% to 95% relative humidity,
application range non-condensing
 IPprotection IP40toEN60529
category
Interface to the Customer:
ThePUIIcanbeincorporateddirectlyintotheuser
networkvia10BaseT.ThePUIIcanalsobelinkedto
themaster7320.000viathisinterface(TCP/IP,SNMP).
Interface to the Sensors Actuators:
ThePUIIprovides4openportsforsensorunits.The
sensorunitsdeterminethefunctionofthePUII.There
is a choice of 4 different sensor units (I/O, access,
climate, FCS, etc.) with varying functions. In this way,
the monitoring functions may be flexibly combined.
Fast, Easy Programming and Installation:
The sensors/actuators are set up via an automatic
electronic ID system. Installation is via a flexible
plug-and-play system. This eliminates the need for
time-consuming programming and wiring.
PowerSupply:
Powerissuppliedcentrallyviaapowerpackinthe
PUII.Theconnectedsensorunitsandallconnected
sensors are supplied with power in this way. There
is a choice of two input voltages (AC power pack
7320.425 and DC power pack 7320.435).
Control Key
The C key is for sensor/
actuator identification,
set-up of the system and
acknowledgement
Alarm LED
The LED signals alarms or
configuration changes
Link/Traffic LED
The LED signals the status
of the network interface
10BaseT/100BaseT
RS 232 Interface RJ 10
For programming via the serial
PCinterface
LEDs Channels of the
Sensor Units
The LEDs indicate the status
of the attached sensor units
Audio Alarm
There is an audio alarm
signaling device integrated
intothePUII
Mounting Attachment
For attachment with nylon
tape, individual bracket
7320.450or1Umounting
units 7320.440
InputsforSensorUnitRJ45
Upto4sensorunitsmaybeconnectedtothe
PUIIviathe4inputs.Thesensorunitsdetermine
thefunctionofthePUII.Thereisachoiceof4
sensor units and specific device connections
suchasLCP,PSMandSK.
– I/O unit 7320.210
– Access unit 7320.220
– Climate unit 7320.230
– FCS 7320.810
Connection cable 7320.470/472/475/481/485
Other connection cables available upon request
Power-12C Bus RJ 45
Upto2voltageextensionunits7200.520maybe
connected via the power I2Cbus.UptothreeAC
voltages may be monitored with every extension
unit. Connection cable 7320.470/472/475/481/485
Alarm Relay RJ 12/ RS 232
The upper RJ 12 jack provides a change-over
contactfromthePUIIalarmrelay.
Connection cable 7200.430
The lower RJ 12 jack provides one serial device
interface(displayunit/GSMmodule/ISDNunit).
Ethernet 10BaseT RJ 45
Integral Ethernet interface to IEEE 802.3 via
10/100BaseT full-duplex 10/100 Mbit/s
PowerSupply
TheratedvoltageforthePUIIis24VDC.There
is a choice of power packs with varying primary
voltages. AC power pack 7320.425
➏ ➐
➒ ➓
1
1
76 RimatriX5 IT Solutions
Monitoring and Security
Processing Unit II (PU II)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
CMC-TC Sensor Unit: I/O Unit
This sensor unit allows alarm and status messages
and measurements to be forwarded or remote actions
to be executed via relay output modules. The I/O unit
has 4 universal inputs/outputs.
The sensors/actuators listed can be operated here.
TheinterfacetotheusernetworkisviathePUII
(ProcessingUnitII),whichisalwaysrequiredtooper-
ate the system.
Control Key for detection/set-up of the sensors/
actuators
Alarm LED signals alarms or configuration
changes
MountingFixture for 7320.440 or 7320.450
RJ12,4InputsforSensors/Actuators
RJ 45, ConnectiontoPUII7320.100via
connection cable 7320.470/472/475/481/485
(The unit is also supplied with power via
this connection.)
Sensor unit I/O unit PartNo.
4 universal inputs or outputs 7320.210
Sensors/Actuators Max. PartNo.
Temperature sensor 4 7320.500
Humidity sensor 4 7320.510
Analog sensor input 4 7320.520
 module“4–20mA”
Access sensor1) 4 x 5 7320.530
 Vibrationsensor 4 7320.540
Airflow monitor 4 7320.550
Smoke alarm 4 7320.560
Motion sensor 4 7320.570
Digital input module 4 7320.580
Digital relay output module 4 7320.590
 Voltagemonitor 4 7320.600
 Voltagemonitorwithswitchoutput 2 7320.610
 Voltagemonitor48VDC 4 7320.620
Water leak sensor 4 7320.630
1)Uptoamaximumof5sensorsmaybeconnectedinseries
Also Required:
Four Sensor Units
I/O Unit:
The alarm and measurement module
Access Unit:
For controlling door systems
Climate Unit:
For fan control and monitoring
Fan Control System FCS for variable speed DC fans
Benefits:
•Choiceoffunctionsthanksto4sensorunits
(activePSM,RTTI/Ounit,RLCPonrequest)
•Opentocustomer-specificsensors/actuators
•Automaticsensordetection
•Simpleinstallationbasedontheplug&playsystem
•Noadditionalpowerpackrequired
•Choiceofmountingontheenclosureframe
or 19" (482.6 mm) mounting angles
•I/Ounit:Freelyselectablesensors/actuators
•Accessunit:Personalizedaccessdetection
•Climateunit:Fancontrolwithairflowmonitoring
Interface for the sensor unit and processing unit
connection.Usedfordatacommunicationand
power supply. Cable 7320.470/472/475/481/485.
Just one press of the button, and the system
automatically reconfigures itself.
Upto3modulesmaybeintegratedintothe1U
mountingunit:PartNo.:7320.440.
TechnicalSpecifications:
The sensors/actuators are set up via an automatic
electronic ID system. Because it is installed
using a flexible plug-and-play system, there is no
need for time-consuming programming and wiring.
Powerissuppliedcentrallyviatheconnection
cabletothePU.
TechnicalSpecifications:
H x W x D: 1.73" x 5.35" x 5.08"
(44mm(1U)x136mmx129mm)
Temperature application range:
41°F to 113°F (+5°C to +45°C)
Humidity application range:
5% to 95% relative humidity,
non-condensing
Protection Category:
IP40toEN60529
1
1
1
1
RimatriX5 IT Solutions 77
Monitoring and Security
Sensor Units
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
CMC-TC Sensor Unit:
Access Unit
With this sensor unit, one or two door zones may be
released for access via the network, or a personal-
ized opening via a code (e.g., smartcard reader) may
be initiated. The system also monitors the status of
the door, handle or latch. Authorized access codes
can be set up via http or file download. The sensors/
actuators/readers listed below can be operated here.
In order to operate the unit, at least one access sensor
and at least one latch (e.g., handle) per door system
must always be used per zone.
  Control Key for detection/set-up of the sensors/
actuators
Alarm LED signals alarms or configuration
changes
MountingFixture for 7320.440 or 7320.450
InputsforAccessSensor,Handles
Latch system 1 (see table)
InputsforAccessSensor,Handles
Latch system 2 (see table)
12C Bus for Reader Units Door system 1 and 2
(see table)
RJ 45 ConnectiontoPU7320.100viaconnection
cable 7320.470/472/475/481/485
(The unit is also supplied with power via
this connection.)
CMC-TC Sensor Unit:
Climate Unit
A temperature control circuit is installed with this
sensor unit. Temperature setpoints are set via the
PUII,andthesearecomparedwiththeactual
temperature. Depending on the evaluation, the fan
system is activated. The function of the fans can also
be monitored with an airflow sensor. Monitoring is only
active while the fan is operational. Other sensors may
optionally be connected to the unit. In order to operate
the unit as a temperature fan control circuit, at least
one temperature sensor must always be used.
Control Key for detection/set-up of the sensors/
actuators
Alarm LED signals alarms or configuration
changes
MountingFixture for 7320.440 or 7320.450
InputforFanSupply115/230VAC,cable
7200210 – 215
OutputtoFanwith cable 7200.215
RJ12,2InputsforSensors (see table)
RJ 45 ConnectiontoPUII7320.100via
connection cable 7320.470/472/475/481/485
(The unit is also supplied with power via this
connection.)
Sensors/Actuators Max. PartNo.
Access sensor1) 2 x 5 7320.530
Digital input module 2 7320.580
Latch/Reader
Electromagnetic Ergoform-S lock 2 7320.70
Electromagnetic Ergoform-S 2 7320.710
Comfort handle for TS8 master key 2 7320.721
 Universallock 2 7320.730
Room door output module 2 7320.740
 Universalhandle 2 7320.950
Smartcard reader for door release 2 7320.750
Magnetic card reader for 2 7320.760
door release
Coded lock for door release 2 7320.770
1)Uptoamaximumof5sensorsmaybeconnectedinseries
Sensor unit access unit PartNo.
Control of 2 door systems 7320.220
Sensor unit climate unit PartNo.
Control of a fan system 7320.230
Also Required:
Sensors Max. PartNo.
Temperature sensor 2 7320.500
Access sensor1) 2 x 5 7320.530
Airflow monitor 2 7320.550
Smoke alarm 2 7320.560
Motion sensor 2 7320.570
Digital input module 2 7320.580
 Voltagemonitor 2 7320.600
 Voltagemonitor48VDC 2 7320.620
1)Uptoamaximumof5sensorsmaybeconnectedinseries
Also Required:
➎ ➏
➋ ➌
1
1
1
1
78 RimatriX5 IT Solutions
Monitoring and Security
Sensor Units
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Benefits:
•Excellentairthroughputata
high operating ratio
•Monitoringoffanspeed
•Plug-and-playcompatibility
system
•EasilyinstalledinRittalfan
roofs/doors
•Longservicelife
•Noiseminimization/speed
control
•AlarmmessageviatheCMC-TC
in the network optionally
possible
•Openpowersupplysystem
24/48VDC/100–230VAC
•EMCcompatibilityviaDC
fan systems
CMC-TC Sensor Unit:
Fan Control System (FCS)
Speed-ControlledFanSystem
The Fan Control System regulates and controls the
speedofupto6fans7320.812,24VDC.Thishelps
to save electricity, reduce the noise level of the fans
and extend the service life of the fans. The failure of
one or more fans is detected and notified in the form
of a collective fault signal via LED display, beeper
and integral alarm relay (floating change-over
contact). Temperature-based control using an external
temperature sensor 7320.500. The temperature set-
point is set via a switch on the front. The system may
also optionally be set and monitored via the network
(Web/SNMP).ItisconnecteddirectlytotheCMC-TC
(processing unit) 7320.100.
FCSExample:
Control System with Fan Regulation and Monitoring
Description Required PartNo.
  Packs
Fan alarm system FCS 1 7320.810
 CMC-TCpowerpack24V
 input100-230VAC 1 7320.425
CMC-TC temperature sensor 1 7320.500
 Fan24VDC(packsof2)with
speed monitoring 3 7320.812
RJ 12 extension for DC fan, 1 m
(packs of 2) 3 7320.814
CMC connection cable D
 230VAC 1 7200.210
ProductProperties PartNo.
7320.810
 Fanspeedmonitoring
 Pre-selectablespeed
 Non-temperaturedependentspeed
 Speedincreaseintheeventofafanfailure
 Collectivefaultsignal
 Floatingchange-overcontact
 LANconnectionviaPUII
 LANviaI/Ounit+PUII
 ConfigurableviaLAN
Alarm output Beeper, LED, relay,
  RJ45outputforPU
Functions:
•Speed-regulatedrpmcontrol
•Fanspeedmonitoring
•OptionalconnectionviaWeb/SNMP
•Redundantfancontrol;theairthroughputofall
fans is automatically increased in the event of a
system failure
•Plug-and-playinstallationviaRJ12connector
system
•19"(482.6mm)mountingispossiblevia7320.440
Note:
Supplied pre-configured on request:
The FCS system may be fitted in all Rittal fan
roofs/doors.
Supplywith24V/48VDCVia
– Supply connection cable direct 7320.813
CMC24Vpowerpack100–230VAC(input)
7320.425
–CMC-24Vpowerpack48VDC(input)
7320.435.Whenoperatingwith48VDC,
fanswith48VDCmustalsobeused
➋ 
RJ 45 Jack for connecting to the processing unit
7320.100 (optional)
CMC-TCTemperatureSensor 7320.500
AlarmRelayOutput48VDC,1A(floating
change-over contact)
FanwithSpeedMonitoring7320.812(24VDC).
48VDCfansmayoptionallybeused
FCS To fit processing unit PartNo.
 Withoutfan • 7320.810
1
1
RimatriX5 IT Solutions 79
Monitoring and Security
Fan Control System (FCS)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
 Packsof PartNo.
2 7320.812
 Packsof PartNo.
1 7320.813
Fan 24 V DC
WithSpeedMonitoring
Fan with integral speed monitoring with RJ 12
connector/connection cable 23.62" (0.6 m) for
connecting to FCS 7320.810.
TechnicalSpecifications:
Ratedvoltage:24VDC
Rated current: 0.28 A (max.)
Rated output: 6.72 W (max.)
Air throughput (unimpeded airflow):
95 cfm (165 m3/h)
Speed: 2650 rpm
Noiselevel:41dB(A)
SupplyConnectionCable
For FCS
Ifthecustomerhasaccessto24Vor48VDC,the
FCS/FAS system may be supplied with power (max.
48VDC)viathesupplyconnectioncable.Nopower
packs are then required for the application.
Length: 78.74" (2 m)
Note:
Fanvariantwith48VDCavailableonrequest.
80 RimatriX5 IT Solutions
Monitoring and Security
FCS Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
CMC-TCDisplayUnit
ForthelocalrepresentationofCMCalarmand
statusmessagesontherack.
TheCMC-TCDisplayUnitisdesignedforconnection
to processing unit 7320.100. It is comprised of 2 lines
each with 20 characters. The character height is
3 mm (.125"). The display is illuminated in order to
ensure legibility even in poor light conditions. It is
mountedinthe1Ucomponentsupport7320.440or
withtheindividualmountingunit7320.450.Power
supply via the processing unit.
The display is also ideal for use as a service tool for
commissioning.
LCDDisplay illuminates 2 x 20 characters
“Change” for selection
“Enter” to confirm
➍ 
“Clear” to delete/acknowledge
➎ 
RJ 12 Jack for Connecting to the serial interface
ofthePUII
➏ 
TheGSMUnitmayoptionallybesuppliedwith
24 V DC, 150 mA via this input. For applications
withthePUII,thisisnotnecessary
TechnicalSpecifications:
•Plug-and-playinstallationviaRJ12connector
•2x20characters
•Characterheight.125"(3mm)
•Illuminated
Includes:
CMC-TC display module, connection cable for con-
nection to the processing unit, operating instructions,
assembly parts.
Note:
Onlyonedevice,either“Display”,“ISDNUnit”or
“GSMUnit”,maybeconnectedtoeachPUII.
CMC-TC GSM Unit
In order to configure a redundant transmission chan-
nel or if there is no network infrastructure available,
this unit may be used for alarm forwarding. The alarm
signalisdesignedinSMSformat.TheGSMunitis
linked to the processing unit 7320.100 via a serial
interface.Powersupplyisalsolinkedtotheprocess-
ing unit via the connection cable. The only other item
needed to operate the module is a SIM card. This
mayeitherbea“dataonly”cardoraconventional
SIMcard.TheGSMunitoperatesinthe900/1800
MHz frequency range – in other words, either D or
Enetworkcardsmaybeused.Uptofourtargetcall
numbers may be set and allocated to the various
events. To activate CMC-TC switch outputs, an SMS
message may be sent to the modem via any commer-
cially available mobile phone. The antenna included
with the supply has a connection cable of 2.8 m.
Voltageissuppliedviatheprocessingunit.
Other functions, when offered by the provider:
•Voicemail
“Clear” to acknowledge
Alarm LED
MountingFixture for 7320.440 or 7320.450
SIM Card Rackmount
Antenna System
RJ 12 Jack for Connecting to the serial interface
ofthePUII
TheGSMunitmayoptionallybesuppliedwith
24 V DC, 500 mA via this input. For applications
withthePUII,thisisnotnecessary
Also Required:
 CMC-TCDisplayUnit PartNo.
Alarm text display 7320.490
Components PartNo.
 ProcessingUnitII 7320.100
A commercially available SIM card for D or E networks
must be provided by the customer.
Note:
Onlyonedevice,either“GSMUnit,”“ISDNUnit”or
“Display,”maybeconnectedtoeachPUII.
 GSMUnit PartNo.
SMS function 7320.820
Components PartNo.
 ProcessingUnitII 7320.100
Also Required:
CMC-TC C
Display
➋ ➌
Power
24 V DC
max. 2 A
C
CMC-TC
GSM Modul
  ➋
Power
24 V DC
max. 2 A
1
1
1
1
RimatriX5 IT Solutions 81
Monitoring and Security
Additional Units
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
ConnectionCable/Extension
The cable is used to connect to:
•CMC-TCmasterII
•24VpowerpackforPUII
•Climateunit(connectedfan)
•Voltagemonitor
•Voltageexpansionunit
•ActivefanunitforTE
TechnicalSpecifications:
PVCcable,3pole,withIECcablecoupling
(non-heating appliances) with contact protection
CEE22.
Power Pack for PU II, FCS
A24VDCpowerpackisrequiredtosupplythe
processing unit II and fan control units with power.
There are two variants available:
•The100–240VACpowerpackrequiresan
IEC connection cable to supply the voltage.
•Analternativepowerpackisdesignedforthetele-
communicationssector(48Vbatteryvoltages)and
is connected at the input end via a terminal block.
Both power packs include an output cable, 64.96"
(1.65 m) long.
TechnicalSpecifications7320.425:
Ratedvoltage:100–240VAC,50/60Hz
Rated current: max. 1.5 A
Secondaryrange:24VDC,3A
TechnicalSpecifications7320.435:
Ratedvoltage:20–72VDC
Rated current: max. 2.5 A
Secondaryrange:24VDC,1.3A
Also Required:
Connection cable for 7320.425 power pack
see below
 Countryversion Voltage PartNo.
D/F/B 230 7200.210
 GB 230 7200.211
CH 230 7200.213
 USA/CDN 115 7200.214
IEC 320 extension 230/115 7200.215
 Primaryinput Output voltage PartNo.
voltage
 100–240VAC/ 24VDC 7320.425
50/60 Hz
 48VDC 24VDC 7320.435
Includes:
1 connection cable, length 98.43" (2.5 m)
82 RimatriX5 IT Solutions
Monitoring and Security
Cable and Mounting Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Programming Cable
The interface cable is used to configure the network
parameters in the processing unit and the master unit.
The RJ 10 connector is connected to the front jack of
thePUII/MasterII,whilethe9-poleSUB-Dconnector
isconnectedtoaserialPCinterface.
 Packsof PartNo.
1 7200.221
Connection Cable RJ 45
This cable is responsible for data exchange and
power supply to a sensor unit via the processing
unit. There is an RJ 45 connector at each end of the
shielded cable.
Connection Cable RJ 10, RJ 12
With the RJ 12 connection cable, the alarm relay out-
put of the processing unit may be used for individual
alarm lights/indicators. The RJ 10 connection cable
facilitates connection to the CMC socket strip in
conjunction with the digital input module. The cable is
equipped with an RJ 10/12 connector at one end. The
other end is open.
ExtensionCableRJ10,RJ12
The cable is used to extend the sensor supply cables
(RJ 12) and individual actuator cables. The cable is
equipped with an RJ 10/12 connector at one end.
There is an RJ 10/12 jack at the other end.
 Lengthin(m) Packsof PartNo.
19.69 (0.5) 4 7320.470
78.74 (2.0) 4 7320.472
196.85 (5.0) 4 7320.475
393.70 (10.0) 1 7320.481
590.55 (15.0) 1 7320.485
 Connector Lengthin(m) Packsof PartNo.
RJ 10 196.85 (5) 4 7200.420
RJ 12 196.85 (5) 4 7200.430
 Connector/jack Lengthin(m) Packsof PartNo.
RJ 10 196.85 (5) 4 7200.440
RJ 12 196.85 (5) 4 7200.450
FCS RJ 12 39.37 (1) 2 7320.814
61
Monitoring and Security
Cable and Mounting Accessories
RimatriX5 IT Solutions 83
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Mounting Unit 1U
The mounting unit can accommodate up to 3 sensor
units or processing units in the 19" (482.6 mm)
attachment level. Cable clamp straps 7610.000 or
7611.000 can be used for cable clamping.
Material:
Sheet steel, spray-finished
Color:
RAL 7035 light grey
 Packsof PartNo.
1 7320.440
Description PartNo.
Cable clamp straps without cable 7610.000
screen contact
Cable clamp straps with spring clips for 7611.000
contacting cable screen
 Packsof PartNo.
1 7320.450
Mounting Module
Mounting module accommodates individual
sensor units or processing units for mounting on
the frame section.
Material:
Sheet steel, spray-finished
Color:
RAL 7035 light grey
84 RimatriX5 IT Solutions
Monitoring and Security
Cable and Mounting Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
TemperatureSensor
The sensor assumes the function of a temperature
monitor and contains an ID so that it is automatically
detectedandsetupbytheCMC-TCsystem.Itis
connected to a sensor unit via the connection cable
supplied loose. If required, extension cable RJ 12
may be used. The sensor can also control a fan on
theclimateunitorfancontrolsystem(FCS).
Humidity Sensor
The sensor measures relative air humidity and con-
verts it into a frequency signal. It contains an ID so
that it is automatically detected and set up by the
CMC-TCsystem.Powersupplyanddataevaluation
is performed by the I/O sensor unit via the connection
cable supplied loose. If required, extension cable RJ
12 may be used.
 Packsof PartNo.
1 7320.500
To fit sensor unit:
I/Ounit Accessunit Climateunit FCS 
• • • 
 Packsof PartNo.
1 7320.510
To fit sensor unit:
I/Ounit Accessunit Climateunit FCS 
•  
TechnicalSpecifications:
Type:NTC
Resistance:10kOhmat77°F(25°C)
Tolerance:3°F(±2°C)
Connection:RJ12jack,6-pole
Connectioncable:Length78.74"(2m),
RJ 12 connector 6/6 on both sides
Temperature application range: 41°F to 113°F
(+5°Cto+45°C)
TechnicalSpecifications:
Sensor: With humidity/frequency converter
(50 kHz at 76% rel. humidity)
Sensor measurement range: Relative humidity
10...90%rel.humidity±3%(at68°F[20°C])
Connection:RJ12jack,6-pole
Connectioncable:Length78.74"(2m),
RJ 12 connector 6/6 at both ends
Temperature application range:
41°Fto113°F(+5°Cto+45°C)
Vandalism Sensor
The sensor contains a position-insensitive alarm
contact and an ID so that it is automatically detected
andsetupbytheCMC-TCsystem.Itisconnected
to the I/O sensor unit via the connection cable supplied
loose. If required, extension cable RJ 12 may be
used. The sensitivity of the sensor may be set using
thePUsoftware.
TechnicalSpecifications:
Mercury-freecontact,position-insensitive
Connection:RJ12jack,6-pole
Connectioncable:Length78.74"(2m),
RJ 12 connector 6/6 at both ends
 Packsof PartNo.
1 7320.540
To fit sensor unit:
I/Ounit Accessunit Climateunit FCS 
•   
RimatriX5 IT Solutions 85
Monitoring and Security
Internal Security Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Access Sensor
The access sensors monitor doors, side panels or
windows in the network enclosure. The magnet is
secured to the moving part (e.g., door), while the reed
contact is fastened to the immobile part (enclosure
frame). The permanent magnet holds the reed con-
tact in a closed position. When the door is opened or
the side panel removed, the reed contact drops off
and opens the circuit. This triggers an alarm in the
CMC-TC. The sensor contains an ID so that it is
automatically detected and set up by the CMC-TC
system. It is connected to a sensor unit via the
connectioncablesuppliedloose.Uptofiveaccess
sensors may be connected in series to one monitoring
line, if necessary in conjunction with extension cable
RJ 12. The jumper plug forms the end.
TechnicalSpecifications:
2 magnets
(mounted on the moving part, directly adjacent)
2 sensors with reed contact
(mounting on the enclosure frame)
Connection 1: RJ 12 jack, 6-pole
(connection to the sensor unit)
Connection 2: RJ 12 socket, 6-pole
(series connection with other access sensors,
or finished with the jumper plug)
2 jumper plugs RJ 12 at the end
2 connection cables: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Water Sensor
The leakage sensor is equipped with an optical
sensor head. If this sensor head becomes wet with
moisture, it reports a leakage alarm. The sensor head
may be mounted towards the floor. If water collects
there and comes into contact with the sensor head,
the alarm is triggered. The sensor contains an ID so
that it is automatically detected and set up by the
CMC-TC system. The connection cable, supplied
loose, should be used for connection to the sensor
unit. If required, extension cable RJ 12 may be used.
TechnicalSpecifications:
Monitoring:Visual
Connection: RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Temperature range: 41°F to 113°F (+5°C to +45°C)
Protection Category:
IP40
AnalogSensorInputModule
The input module facilitates the connection of individual
external analog sensors (4 – 20 mA) to the I/O sensor
unit. As an adapter, it performs the function of iden-
tification, so that an external sensor is automatically
identified and set up by the CMC-TC system. Sensors
with4–20mAsignaloutputand24VDCoperating
voltage (max. 50 mA) may be connected. The
CMC-TC makes its internal voltage source available.
It is connected to a sensor unit via the connection
cable supplied loose. If required, extension cable RJ
12 may be used.
TechnicalSpecifications:
Analoginput:4–20mAat24VDC
Maximum current output of the module: 50 mA
SensorswithoutGNDmayalsobeused.
Connection: RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Sensorconnection:Pull-offclampingstrip,3-pole
 Packsof PartNo.
2 7320.530
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• • •  
 Packsof PartNo.
1 7320.630
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•   
 Packsof PartNo.
1 7320.520
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
86 RimatriX5 IT Solutions
Monitoring and Security
Internal Security Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Airflow Monitor
The airflow monitor determines whether the fan is
achieving its full operating capacity. Damage, dirty
filter mats or jammed fan blades are promptly detected
and reported by the sensor. The sensor contains an
ID so that it is automatically detected and set up by
the CMC-TC system. Its switch point is adjustable.
Powersupplyanddataexchangetothesensorunit
occurs via the attached connection cable. If required,
extension cable RJ 12 may be used.
Voltage Monitor
The voltage monitor picks off a mains voltage to be
monitored via the mains cable, and reports its status
toasensorunit:VoltageONorvoltageOFF.The
monitor contains an ID so that it is automatically
detected and set up by the CMC-TC system. The
connection cable, supplied loose, should be used for
connection to the sensor unit. If required, extension
cable RJ 12 may be used. TechnicalSpecifications:
Monitoredratedvoltage:230VAC50/60Hz
Connections: IEC connector, RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Temperature application range: 41°F to 113°F
(+5°C to +45°C)
Protection Category:
IP40
TechnicalSpecifications:
Connection: RJ 12 jack, 6-pole on the cable
Connection cable: Length 78.74" (2 m)
Temperature application range:
41°F to 113°F (+5°C to +45°C)
Note: The sensor can be operated with temperature
controlled fan via the climate unit sensor unit.
Smoke Alarm
The smoke alarm is based on an opto-electronic
smoke particle evaluation within a measurement
chamber. The alarm contains an ID so that it is
automatically detected and set up by the CMC-TC
system.Powersupplyandalarmrelaytothesensor
unit occurs via the supplied connection cable. If
required, extension cable RJ 12 may be used.
TechnicalSpecifications:
Alarm type: Combustion product alarm (smoke)
Sensor/transmitter:
SiliconPINphotodiode/GaAsinfr.LED
Measurement frequency: Once every ten seconds
Powerconsumption:max.61mA
Connection: RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Dimensions (alarm with base/plinth):
H = 50 mm (1.97"), D = 3.94" (100 mm)
Temperature application range:
41°F to 113°F (+5°C to +45°C)
 Packsof PartNo.
1 7320.560
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• •  
 Packsof PartNo.
1 7320.550
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• •  
 Packsof PartNo.
1 7320.600
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• •  
Monitoring and Security
Internal Security Accessories
RimatriX5 IT Solutions 87
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Voltage Monitor 48 V DC
The voltage monitor picks off the mains voltage to be
monitored via the 3-pole jack, and reports its status to
asensorunit:VoltageONorvoltageOFF.Themonitor
contains an ID so that it is automatically detected and
set up by the CMC-TC system. The connection cable,
supplied loose, should be used for connection to the
sensor unit. If required, extension cable RJ 12 may
be used.
TechnicalSpecifications:
Monitoredratedvoltage:48VDC
(12–60VoltDC/12–25VoltAC50/60Hz)
Connections: 3-pole connector, RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Temperature application range: 41°F to 113°F
(+5°C to +45°C)
Protection Category:
IP40
Voltage Monitor with IEC
SwitchOutput
This sensor is used in conjunction with the CMC-TC
to monitor voltage limits. The limits may be set via the
WEBinterfaceorSNMP.Asanadditionaloption,this
voltage may also be switched on and off via the
module, in order to reboot connected equipment via
Ethernet. It is connected via standard, commercially
available IEC320 connectors as the input signal, and
an IEC320 socket is used to connect the equipment.
TechnicalSpecifications:
•Plug-and-playinstallationviaIEC320connector
•Theswitchingoperationmaybeinitiatedinatime
orevent-basedmannerorviaSNMPorWEB
•Themaximumandminimumlimitsofvoltage
measurement are freely selectable
•Measurementrange100–250VAC,50/60Hz
•Max.switchingload250VACand8Aatpower
factor = 1
•Tolerance:±5%at68°Fto86°F(+20°Cto+30°C)
Note:
The system has two functions.
Each function occupies one input of the I/O unit.
1stfunction:Voltagemeasurement
2nd function: Relay switching
OptionallyAvailable:
IECconnectioncable7200.214,USversion,
IEC extension cable 7200.215 for connecting
the equipment and high voltage input
 Packsof PartNo.
1 7320.610
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
 Packsof PartNo.
1 7320.620
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• •  
DigitalSensorInputModule
The input module facilitates the connection of individual
external digital sensors to a sensor unit. As an adapter,
it performs the function of identification, so that an
external sensor is automatically identified and set up
by the CMC-TC system. External sensors or detectors
must have a floating contact (normally closed or
normally open), because the module makes its internal
voltage source available. It is connected to a sensor unit
via the connection cable supplied loose. If required,
extension cable RJ 12 may be used. In conjunction
with the access unit, any given door release system
(e.g., transponder) with a floating relay contact may
be connected via the input module.
TechnicalSpecifications:
Floatingexternalsensorcontact:Voltagemin.
24VDCloadcapacity
Current: min. 10 mA load capacity
Connection: RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Sensorconnection:Pull-offclampingstrip,3-pole
 Packsof PartNo.
1 7320.580
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• • •  
88 RimatriX5 IT Solutions
Monitoring and Security
Internal Security Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
DigitalRelayOutputModule
The output module allows individual, external low
voltage actuators to be switched via a change over
contact. As an intermediate relay, it performs the
function of identification and isolation, so that an
actuator is automatically identified and set up by
the CMC-TC system.
It is connected to the I/O sensor unit via the connec-
tion cable supplied loose. If required, extension cable
RJ 12 may be used. At the output end, the module
contains a pull-off terminal strip for assignment with
actuatorcables.Powersupplytotheactuatormustbe
provided externally. The output relay may be switched
remotelyviaSNMPorHTTP.Alternatively,alarmlinks
can also be created with alarm inputs.
TechnicalSpecifications:
Conditionoftheactuator:cosPhi=1
Max.loadoftheswitchcontact:1A,30VDC
and0.5A,48VAC
Max.switchingvoltage:48VAC;48VDC
Max. switched current: 1 A
Max.switchingload:30W,62.5VA
Min.switchedcurrent:1mAat5VDC
Connection: RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Sensorconnection:Pull-offclampingstrip,3-pole
CMC-TC Motion Detector
The motion detector may be used in network enclosures
or in rooms. Any changes to the enclosure, such as
opening a door or side panel, are indicated. The
motion detector can also detect presence in the room
or in front of the data cabinet.
The alarm contains an ID so that it is automatically
detectedandsetupbytheCMC-TCsystem.Power
supply and data exchange to the sensor unit is via
the connection cable, supplied loose. TechnicalSpecifications:
Alarm type: Infrared (IR) detector
Range: max. 275.59" (7 m)
Powerconsumption:max.30mA/24VDC
Connection: RJ 12 jack, 6-pole
Connection cable: Length 2 m,
RJ 12 connector 6/6 at both ends
Dimensions: W x H x D: 4.02 x 2.32 x 1.26"
(59 x 102 x 32 mm)
 Packsof PartNo.
2 7320.570
To fit sensor unit:
I/O unit Access unit Climate unit FCS
• •  
 Packsof PartNo.
1 7320.590
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
CMC-TCExtensionUnit
The CMC-TC extension unit picks off three indepen-
dently monitored mains voltages via network cables
and forwards the measurements to the processing
unit.ItislinkedtothePUIIviatheRJ45connection
cableontheP-12Cport(sep.accessory).Uptotwo
extensionunitsmaybeconnectedinseriestoonePUII.
A separate power pack is not required. Alarm limits
may be preset for all voltages.
TechnicalSpecifications:
Voltageinputs:3x100–230VAC,IECconnector
Interface: I2C,P-I2C, max. cable length 78.74" (2 m)
Temperature application range:
41°F to 113°F (+5°C to +45°C)
Protection Category:
IP40
 MaximumnumberperPUII Packsof PartNo.
2 1 7200.520
Monitoring and Security
Internal Security Accessories
RimatriX5 IT Solutions 89
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
RoomDoorOutputModule
The room door output module allows external door
opener systems to be switched via a change-over
contact. As an intermediate relay, it performs the
function of identification and isolation, so that a door
opener is automatically identified and set up by the
CMC-TC system.
It is connected to the access unit via the connection
cable supplied loose. If required, extension cable RJ
12 may be used. At the output end, the module
contains a pull-off terminal strip for assignment with
theactuatorcables.Powersupplytothedooropener
must be provided externally.
TechnicalSpecifications:
Conditionoftheactuator:cosPhi=1
Max. load of the switch contact:
1A,30VDCand0.5A,48VAC
Max.switchingvoltage:48VAC;48VDC
Max. switched current: 1 A
Max.switchingload:30W;62.5VA
Min.switchedcurrent:1mAat5VDC
Connection: RJ 12 jack, 6-pole
Connection cable: Length 78.74" (2 m),
RJ 12 connector 6/6 at both ends
Sensorconnection:Pull-offclampingstrip,3-pole
Note: For each output module, one access sensor
7320.530 is always needed for access control.
CMC-TCAlarmSignalLamp
The alarm signal lamp serves as a collective fault
signal for all alarms in the CMC-TC.
Example: Temperature exceeded, fan defect, smoke
alarm etc. The CMC-TC provides a user-friendly menu
allowing the operator to select which message will
affect the CMC-TC alarm relay. The alarm signal lamp
is activated via the alarm relay.
The lamp may be attached to the network enclosure
or any other desired position, e.g., in the corridor.
The RJ 12 connection cable is required for
connectiontothePUII.
InterferenceSuppression
CapacitorsforFans
The capacitors are used for the interference suppres-
sion of fans with self-starting shaded pole motors.
One capacitor should be connected directly parallel
to the mains voltage for each fan unit. The capacitors
are equipped with a terminal, which means that they
are easily fitted to the fan cable.
TechnicalSpecifications:
Ratedoperatingvoltage:24VDC
Rated current: 60 mA
TechnicalSpecifications:
Dielectricstrength:275VAC
Capacity: 100 nF
Type: X2
Item PartNo.
LED steady light 2372.000
 component24VDC,red
Connection component 2368.010
 TofitPUII:
 Processingunit FCS RLCP SK 
• • • • 
 Design Packsof PartNo.
100 lF 20 7200.490
 Packsof PartNo.
1 7320.740
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
90 RimatriX5 IT Solutions
Monitoring and Security
Internal Security Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Comfort Handle for TS8 Unit
with Master Key Function
The TS8 handle 7320.721 includes the master key
function. This means that the handle can always be
opened with a key, the master key, independently of
the control system. A semi-cylinder is supplied loose,
but a semi-cylinder 40 or 45 mm overall length to
DIN18254mayalsobeused.
The handle assumes the function of door locking
and lever handle monitoring. An access sensor
(7320.530) must be connected to the corresponding
door for each handle. If the lever handle is closed,
the locking mechanism integrated into the handle
latches automatically.
The handle may be released via the CMC-TC system
in the network or via optional add-on systems, such
as smartcard readers, etc. The handle is locked in a
de-energized manner (without electrical connection).
The push-button may be depressed following electri-
cal release and then opens the lever automatically.
Opening via the key is always superordinate, i.e., the
enclosure may always be opened with the key in the
case of electrical locking and in the event of a power
failure (emergency opening).
Handle Systems
with Electromagnetic Lock
The lock unit consists of a Rittal handle system whose
handle is electromagnetically locked. It contains an
identifier so that it is automatically detected and set
up by the CMC-TC system.
Powersupplyanddataexchangetotheaccessunit
is via the attached connection cable. An access
sensor (7320.530) is always required for door moni-
toring. With the door closed and the handle locked
home, latching is activated by energizing the lock
magnet. The CMC-TC enables the handle to be
pulled out by deactivating the lock magnet, thereby
allowing the door to be opened. This deactivation can
be initiated via an access unit such as a smartcard
reader, magnetic card reader, coded lock and/or
network management systems. The handle system
also comprises handle monitoring. The CMC-TC
reports an alarm if the handle is not pushed in and
locked home after closing the door. The push-button
insert supplied can also be exchanged for lock inserts.
Note:
When using the Ergoform-S handle, an additional hole
is required.
Additional hole for electronic lock
(PS/FR/QR/TC/TE)
TechnicalSpecifications:
Ratedvoltage:24VDC
Rated current: max. 100 mA
Connection cable: Length 118.11" (3 m),
RJ 12 connector
Connection cable: Length 78.74" (2 m),
RJ 12/RJ 12 connector
Coupling for extension: RJ 12/RJ 12 jack
Temperature application range:
41°F to 104°F (+5°C to +40°C)
Protection Category:
IP40
Note:
ForPSandFRglazeddoors,thelockingbarslisted
below are required:
TechnicalSpecifications:
Ratedvoltage:24VDC
Rated current: max. 100 mA
Connection cable: Length 118.11" (3 m),
RJ 12 connector
Connection cable: Length 78.74" (2 m),
RJ 12/RJ 12 connector
Coupling for extension: RJ 12/RJ 12 jack
Temperature application range:
41°F to 104°F (+5°C to +40°C)
Protection Category:
IP40
Locking Bars
Design PartNo.
Lower door locking bar for 78.74" 7200.371
 (2000mm)highPSenclosures
Lower door locking bar for 78.74" 7200.372
(2000 mm) high FR enclosures
Lower door locking bar for Available on
TE enclosures request
Other sizes available on request.
424279.2 + 0.1
50
50
87
8
18 ± 0.1
6
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
Handle system PartNo.
Ergoform-S handle for 7320.700
 FR,PS,TC,TE
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
1
1
Design PartNo.
Comfort Handle 7320.721
RimatriX5 IT Solutions 91
Monitoring and Security
Access Systems Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Comfort Handle
For lock inserts
Preparedfortheinstallationoflockinserts,safetyand
push-button inserts.
Length:
11.61" (295 mm)
Color PartNo.
RAL 7035 light grey 8611.020
RAL 9005 black 8611.350
Security handle 7200.800
Design PartNo.
Security lock insert no. 3524 E 8611.180*
 Push-buttoninserts 8611.190
 Push-buttonandlockinserts,lock 8611.200
no. 12321; no other lock is possible
* 2 keys included
Lock and Push-Button Inserts
For installation in the comfort handles for lock inserts.
Design PartNo.
 Greybrown 2451.000
RAL 7035 light grey 2435.000
Design PartNo.
RAL 7035 light grey 8611.070
RAL 9005 black 8611.360
Ergoform Handles
Preparedfortheinstallationofsemi-cylinderswith
a total length of 1.6 or 1.8" (40 or 45 mm)
(toDIN18254)andall1.1"(27mm)lockinserts.
Design PartNo.
Security lock insert no. 3524 E 2467.000*
 Push-buttoninserts 2468.000
 Push-buttonandlockinserts,lock 2469.000*
no. 2123 E; no other lock is possible
* 2 keys included
Lock and Push-Button Inserts
For installation in:
•Comforthandleforsemi-cylinder,seeabove
•Ergoformhandles,seeabove
•CMhingedhandle
Indicates its use with TS8 products Indicates its use with TE 7000 products
Comfort Handle
For Semi-Cylinder
Preparedfortheinstallationofcommerciallyavailable
semi-cylinders, 1.6 or 1.8" (40 or 45 mm) total length,
toDIN18254.
Length:
11.9" (302 mm)
Also Required:
Handle adapter for mounting on a TS glazed door,
PC-TSbottomdoor,IWdesignerdoor.
92 RimatriX5 IT Solutions
Monitoring and Security
Access Systems Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
33.5
50 50
239
36
50 + 0.25050 + 0.2
25 + 0.2
112
z
z
7
7
Handle System for Universal
Installation
with Electromagnetic Lock for the
CMC-TC Monitoring System
The universal handle is equipped with a pitch pattern
of mounting holes which will fit many existing door
systems. This handle is ideal for retrofitting to projects
with varying enclosure types and variants. The new
handle may be connected to the CMC-TC system via
plug-and-play.
Additionally, an access sensor (7320.530) should
always be used to enable polling of the door status.
The handle is equipped with a connection cable and
an RJ 12 connector, which may be plugged into the
access unit 7320.220 of the CMC-TC system. The
handle is equipped with a push-button insert which
may be depressed when the electromagnetic lock
is released.
TechnicalSpecifications:
Ratedvoltage:24VDC
Rated current: max. 100 mA
Connection cable: Length 196.85" (5 m),
RJ 12 connector
Note:
The handle only fits into the cutout shown in the
drawing. For other hole patterns, additional adapters
and/or machining of the door are needed. Solutions
provided on request.
Type PartNo.
Electromagnetic CMC-TC 7320.9501)
handle
1) Special order, extended delivery times
To fit sensor unit:
I/O unit Access unit Climate unit FCS
•  
TS8TransponderHandle
withIntegralTransponderReleaseSystem
from Simons & Voss
The electromagnetic TS8 transponder handle may be
retrofitted in the doors of TS8 enclosures. The handle
is equipped with an integral radio transponder solution.
The transponder receiver with battery is integrated
into the handle housing. Apart from the transponder
transmitter, no additional accessories, such as
additional electronics, cables, power pack, etc., are
required. The handle is easily exchanged without the
need for wiring. If battery servicing is required, this is
indicated acoustically.
The handle is supplied in the zero state, so that it may
be opened with any transponder transmitter.
Use with hand-held transmitter:
The transponder transmitter is actuated from the
handle, as a result of which the latter is unlatched
for a specified time window and may be opened by
pressing the push-button.
Use with the CMC-TC transmitter:
The transponder transmitter is linked to the CMC-TC
system via the room door output 7320.740 and the
access unit. The transmitter is placed in the enclosure
frame, near the handle. In this way, the door may be
released via the CMC-TC system. Additionally, an
access sensor (7320.530) should always be used to
enable polling of the door status.
Useoftheprogrammabletransponder:
The programmable transponder allows the individual
transponder transmitters to be allocated to individual
handles. Matrix programming is supported.
Type PartNo.
Electromagnetic Transponder,
handle stand alone 7320.9601)
application
Transponder Hand held 7320.9611)
transmitter transmitter
Transponder CMC-TC 7320.9621)
transmitter transmitter
 Programmable Programming 7320.9631)
transponder
1) Special order, extended delivery times
Benefits:
•Nocablesonthehandle,becausetheelectronics
and battery are integrated into the handle
•Severalusersmaybesetforonehandle
•Plug-and-playinstallationbothmechanicaland
electrical
•Individualcontrolofthetranspondersandthe
set-up of each transponder is possible for up
to 3 locking systems
•Withadditionaloverlaytoautomaticallyblockthe
old transponder in the event of reprogramming
•Counterfeit-proofdatacommunicationisachieved
via radio using crypto-codes
•The“challengeresponseprocedure”ensures
protection against surveillance
•Thestandardinterfacemeansthatconnections
to other access and monitoring systems are not
a problem
The lock and organization system is graded in the
highest category with respect to unlocking protection
to BSI 7500.
Systems with extra electronics and access control
fromSimons&Vossavailableonrequest.
Monitoring and Security
Access Systems Accessories
RimatriX5 IT Solutions 93
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Access Systems Legic
Transponder
With the CMC-TC system, Rittal offers an access sys-
tem for racks and IT rooms. One form of access con-
trol is release with Legic transponder technology. The
popular Legic system is often used in IT applications.
With the Legic-Rittal transponder, the same transpon-
der cards may be used. The contactless system has
many advantages (low wear, positioning, etc.).
The transponder system may be linked to the serial
interfaceoftheProcessingUnitII(PUII).Inthisway,
the access units with the doors may be activated.
The24VDCpowerissupplieddirectlyviatheserial
PUIIconnection.Codeallocationisimplementedvia
atablewhichmaybeloadedontothePUIIviaFTP.
The system may be flush-mounted in rooms, or
on an enclosure. An integral LED provides the
status display.
Transponder On request
To fit PU II –
TechnicalSpecifications:
Ratedvoltage:24VDC
Interface: RS232
Transmission system: Legic transponder
Carrier frequency: 13.56 MHz
Protectioncategory:IP44
Temperature range: 14°F to 131°F (-10°C to +55°C)
Humidity: max. 90% without condensation
Universal Lock Unit
The security lock consists of a base unit and a lock
catch. The base unit is attached to the enclosure
frame. The lock catch is attached to the door.
A mechanical setting allows you to choose between
two states: at zero current when open, or at zero
current when closed. In order to identify the operating
mode used, one of the two identifier modules (sup-
plied loose) should be used, so that it is automatically
identifiedandsetupbytheCMC-TCsystem.Power
supply and data exchange is via the access unit,
using the identifier modules and connection cables
supplied loose. If required, extension cable RJ 12
may be used. An access sensor (7320.530) is always
required for door monitoring.
TechnicalSpecifications:
Ratedvoltage:24VDC
Rated current: 140 mA
Temperature application range: 50°F to 104°F
(+10°C to +40°C)
Includes:
1 base unit with connection cable 3.94" (0.1 m),
RJ 12 connector
1 lock catch
2 identifier modules with RJ 12 jack, 6-pole
(connection to access unit), RJ 12 jack, 6-pole
(connection to universal lock)
1 connection cable for identifier modules, 87.74"
(2 m), RJ 12/RJ 12 connector without mounting kit
Note:
Attachment kits for the various different enclosure
types and enclosure doors can be taken from
the table.
Lock unit PartNo.
 Packsof1set 7320.730
To fit sensor unit:
I/O unit Access unit Climate unit
 •
94 RimatriX5 IT Solutions
Monitoring and Security
Access Systems Accessories
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Smartcard Reader/Magnetic
Card Reader/Coded Lock
The door handle is released to authorized persons
who have identified themselves with a smartcard/
magnetic card/combination code. Smartcard readers/
magnetic readers/coded locks are installed above the
enclosure handle and can also function as a
central unit for releasing several doors.
The entire access procedure can also be registered
with the CMC-TC where there is network connection.
TechnicalSpecifications:
Ratedvoltage:24VDC
Rated current: max. 20 mA
Interface: I2C bus
Smartcard type: I2C chip
Magnetic card type: Magnetic stripe cards with data
on track 2. The reader system is designed for both
high and low magnetized cards.
Note:
Smartcard readers/magnetic card readers/coded
locks may only be used in conjunction with the
CMC-TC and an electric lock. Three cards are
supplied with the smartcard reader/magnetic card
reader. Each card contains a four-digit code, which
is different on all three cards. All cards are access-
authorized. The code may be input directly on the
coded lock. Authorized codes may be set in the
CMC-TC via WEB. The input code is transmitted to
the CMC-TC and, where applicable, to the network
management system, via the I2C bus. A mounting
adapter for a TS8 aluminum glazed door is supplied
loose with every reader.
To fit sensor unit:
I/O unit Access unit Climate unit
 •
Read system PartNo.
Smartcard reader 7320.750
Magnetic card reader 7320.760
Coded lock 7320.770
25
190
50
120
166
83
8.5
4
35
190
50
120
166
83
8.5
4
25
190
50
120
166
83
8.5
4
Monitoring and Security
Access Systems Accessories
RimatriX5 IT Solutions 95
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Monitoring of Climate
Control Units
The interface card is an extension for TopTherm
cooling units with Comfort controller. In this way it is
possible, e.g., to monitor a master/slave combination
of up to 10 cooling units. Control is via standardized
interfaces:RS232(DB9)orRS485,onePLCinterface
(DB9). The RTT I/O unit may also be connected to the
ProcessingUnitII.Thismeansthatremotemonitoring
can be achieved via the network. The extension card
isbuiltintoa1Uplastichousing.Avoltagesupplyof
24VDCisneeded.Thismaybesuppliedfromthe
CMC-TC via a wide-range power pack 7320.425
(100to240VAC,50/60Hz)orexternallyviaaKycon
connector.
SupplyIncludes:
Interface card integrated into plastic box W x H x D:
in(mm)5.35x1.7x5.07(136x44[1U]x129).
Serial sub-D cable 59.06" (1.5 m).
Functions/settings:
– Setpoint temperature for enclosure
– Alarm temperature value for enclosure
– Warning temperature value for enclosure
– Filter mat monitoring
Warnings/alarms:
– Internal temperature too high
– Icing
– High-pressure sensor
– Leakage
– Condenser/fan defect
– Evaporator coil/fan defect
– Compressor defect
– Sensor failure, condenser temperature
– Sensor failure, ambient temperature
– Sensor failure, icing sensor
– Sensor failure, condensate level
– Sensor failure, internal temperature
–Phasemissingorincorrect
–EEPROMdefect
Includes:
ProcessingunitPUIIwithfirmware/softwarefor
applications with climate control units, Interface
card, climate control unit RTT-I/O unit (3124.200)
Powerpack24VDC,input100–240VAC
(7320.425), Connection cable D with IEC320
connector (7200.210), Cat5 connection cable,
78.74" (2 m), for RTT-I/O unit to the processing unit
PU,DatacableRS232,78.74"(2m),forconnecting
the RTT-I/O unit to the RTT climate control unit with
comfort control.
Accessories
Interface card RTT-I/O unit 3124.200
(maximum of 3 additional cards)
➋ ➌ ➍ ➐
➑ ➒
8910 12
11
Power
1234
24 V DC
max. 160 mA
RES MEM
LAN
12 3 4 56 7
RTT I/O unit
PLC X2
G+ -
RS-485
LAN COM RS-232
1
1
  
PLC X2 Opto-CouplerAlarmoutputsforPLC
LAN LED Internal communication
COM LED Status of serial interfaces
RJ 45 for connecting to processing unit 7320.100
RS-485 Interface
RS-232forset-upwithaserialPCinterface
(e.g., Hyperterm)
MountingFixture for 7320.440 or 7320.450
The unit may optionally be supplied with 24 V DC,
160 mA via this input. For applications with the
PUII,thisisnotnecessary
RES Reset Key
MEM EEPROM Fault
Changeover Switch Serial interface
LAN Connection to the master cooling unit with
comfort control
96 RimatriX5 IT Solutions
Monitoring and Security
For Climate Control Units
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Control Console
TheKVMControlConsoleisanidealsolutionto
optimize your space efficiency. It allows you to control
yoursystemswithonlya1Udeviceandcontrolup
to eight platforms. You can also easily expand the
connections up to 512 systems with the combination
ofKVMswitchboxes.ItsTFTLCDdisplayand
industrial level keyboard/trackball provide the
user-friendliest and most reliable environment for
network administrators.
Features:
•Industrialgradekeyboardwithtrackball
•OSD(OnScreenDisplay)function
•HighbrightTFTLCDdisplay
•1Ucompactdesign
•Built-Inpowersupply
•8portKVMswitchwithDB-25pinconnector
(optional)
•Controlsupto512systemsbycascading
Material
Heavy-duty steel
Dimension
15" – (44 mm H x 440 mm W x 492 mm D)
17" – (44 mm H x 440 mm W x 550 mm D)
Gross Weight
40 lbs (18 kg)
Color
Black
Keyboard
PS/284keyskeyboardwith15mmtrackball
supportingUS,UKEnglish,German,Belgium,Switch,
Spanish,French,Italian,Norwegian,Portugal,Finnish
and Swedish
LCD
15" or 17" TFT LCD panel display with built-in back
light protection function
Brightness
200 nits brightness
Description PartNo.
 1U15"LCDPanelDrawerw/ 9969.549
 CherryK/B,8portKVMSwitch,Black
 1U17"LCDPanelDrawerw/ 9969.562
 CherryK/B,8portKVMSwitch,Black
 15"LCDPanelDrawerw/ 9969.973
CherryK/B,withoutKVM
 17"LCDPanelDrawerw/ 9969.972
CherryK/B,withoutKVM
 Note:Touchpadandtouchscreenpointing
device options available on request
OptionalPeripherals
Description PartNo.
 connectingcablewithVGA,PS/2
keyboard and mouse connectors at 9969.550
platform side, 70.87" (1.8 m)
 connectingcablewithVGA,PS/2
keyboard and mouse connectors at 9969.561
platform side, 118.11" (3 m)
KVMSwitch(optional)
8 x 25 pin D type female connectors for 8-platform
connection(VGA,PS/2keyboardandPS/2mouse
male connectors at the platform side)
Portselectionthroughfrontpanelswitches,hotkeys,
or On Screen Display Cascading up to 512 systems
Security Lock
Front access lock for system security
Drawer Design
Full extension high load rating slide rail. Total drawer
travel distance: 15.16" (385 mm)
PowerSupply
Industrial level
RimatriX5 IT Solutions 97
Monitoring and Security
ControlConsoleDrawer,OptionalKVM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
CMC-TC Manager
ThenewCMC-TCmanagerallowsallRittalSNMP
agents to be managed in a single software package.
•CMCII(7200.100)
•PCUWebsockets(7200.000)
•CMC-TCprocessingunit(7320.100)
The graphical interface provides the relevant
information about the system and offers the option
ofconfiguringthesystemsviaSNMP.JavaRuntime
Environment JRE 1.5 (or higher version) should be
installedonthecorrespondingPCsystem.Javamay
be downloaded from the Internet at www.sun.com.
Thevariousproducts(PCU,CMCII,CMC-TC)may
be sorted on the basis of type or location. All alarm
messages enter the built-in trap receiver, and can
be recorded with the logging function. The alarm
messages can be forwarded directly using the e-mail
function. The search function is used to distinguish
andautomaticallylisttheSNMPagents.
Benefits:
•OpentooperatingsystemsviaJava
(Windows/ Linux)
•Graphicalinformationandoperatorinterfacefor:
– CMC II
–WebsocketstripPCU
– CMC-TC/processing unit
–HPCMC
•Fullintegrationofthemanagementinformationbase
(MIB) of Rittal systems
•Trapreceiverwithloggingfunction
•E-mailssentintheeventoftrapalarmmessages
•Systemsearchfunction
•User-orientedsystemlistingaccordingtolocations
Note:
The software is available free of charge from the
Internet. www.rittal-it.com
Network Management Systems
ByusingSNMPnetworkmanagementsystems
suchasHPOpenVieworNovellManageWise,itis
possible to incorporate and address the CMC-TC
systemviaSNMP.TherequiredMIBisincludedwith
the supply.
The MIB is easily incorporated by simply copying.
The standard MIB-II (RFC 1213) is also supported.
ItisincludedwiththesupplyoftheNMS.Theprivate
MIB contains all the required system variables, and is
easilylinkedtothefunctionsofthesoftwareHPOpen
View,NovellManageWise,etc.
Note:
The MIB is also available to download on the Internet
at www.rittal-it.com and is included with the supply of
every CMC-TC system
CMC-TC Configurator
The CMC-TC Configurator automatically compiles all
the modules and accessories required for a CMC-TC
project. The user simply enters the monitoring require-
ments and the ambient conditions. The result is a list
containing all the item numbers required for the
project. In this way a project can be compiled quickly
and effectively. The prerequisite for working with this
softwareisMSExcel,Version97orabove.
Note:
The CMC-TC Configurator is available
for free downloading on the Internet at
www.rittal-it.com
Plug-InforHPOpenView
ThankstoitsintegrationintoHPOpenViewNNM,
StableNet TM CMC-TC is centrally and permanently
available.ThemanagementfunctionsofHPOpen
Viewhavebeenextendedtooptimumeffect:NNM
monitors the traps occurring in CMC-TCs and
forwardsthemtoStableNetTM CMC-TC. The MIB of
the CMC-TC system processing unit (7320.100) has
been incorporated.
Functions:
•Integraltrapmanager
•Variousalarmfunctions,e.g.,e-mail,SMS,etc.
•IntegralMIBbrowser
•Graphicaldisplayofthemonitoredvalueswith
diagrams and tables
•Individualrepresentationandorganization
of the monitoring tools
•Pre-configuredgraphicalinterfacefortheCMC-TC
•Microsoft® Outlook®“lookandfeel”
•Non-platform-dependent(JAVA)
OtherproductsfromtheStableNetTM suite with
theoptionofintegratingtheStableNetTM CMC-TC
manager:
StableNetTM ARC Advanced Router Configuration
•Managementofallnetworkcomponentsand
CMC-TCsfromwithinHPOpenViewNNM
•Efficientmanagementofroutersandswitches
StableNetTMPMEPerformanceManagement
Engine
•EvaluationofthedataobtainedwithStableNetTM
CMC-TCs by means of comprehensive reporting
functions
•Diverseopportunitiesformeasuringnetwork
performance
Note:
Further information can be found on the Internet at:
www.infosim.net
or by sending an e-mail inquiry to:
info@infosim.net
98 RimatriX5 IT Solutions
Monitoring and Security
Remote Monitoring Software
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Monitoring and Security
Notes
RimatriX5 IT Solutions 99
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
100 RimatriX5 IT Solutions
Power
RimatriX5 IT Solutions from Rittal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
RimatriX Modular UPS ................................................................................................................... 102
Single-Phase (UPS) ........................................................................................................................ 106
Power Distribution Units (PDU) ..................................................................................................... 110
The IT trends of today and tomorrow show rack density increasing as more and
more servers are installed in standard cabinets. In correlation to this recent IT trend,
overall rack power requirements are rising as well. In anticipation to the changing
needs of the IT industry, Rittal is not only well prepared to address the escalation
of cabinet power demands, but Rittal is able to do it while reducing installation and
operation costs and increasing operational reliability.
The power management product range for power distribution in the data center
is based on the consistent implementation of plug-and-play expansion – with no
need to interrupt current operations. Downtimes are avoided and future operating
costs are decreased.
RimatriX5 IT Solutions 101
Power
RimatriX5 IT Solutions from Rittal
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
Introducing the RimatriX Modular UPS
UninterruptiblePowerSupply
Designed specifically for high-density computing environments, the
RimatriXModularUPSdelivers12kWofefficient,reliablepowerinonly
6Uofstandardrackspace,includingbatteries.Expandcapacityby
combining 12 kW modules in a building block fashion to deliver 60 kW
of redundant backup power from a single rack enclosure. This powerful
configuration delivers higher power density than competitive, modular
solutions, while dissipating one-third of the heat.
The standard internal batteries provide needed ride-through power until
an auxiliary power source takes over or systems are gracefully shut
down. Extend runtime up to 34 minutes at full load (or 76 minutes at
halfload) with Extended Battery Modules (EBMs).
Meet Current and Changing Requirements with Modular Architecture
ThebuildingblockoftheRimatriXModularUPSsystemisa6Urackmountmodule
that provides 12 kW of backup power protection. The system expands easily to pro-
vide maximum results. As your data center grows, the system’s modularity plays a
keyroleinoptimizingyourcapitalplanninganddeployment.Usingthepatentedand
field-provenPowerwareHotSync® paralleling technology, up to six RimatriX Modular
UPSmodulescanbeparalleledforextracapacityorredundancy,providing60kWof
redundant backup power protection in one 19" rack.
Patentedload-sharingcontrolintelligentlydistributestheworkloadamongmodules
without requiring direct synchronization links among them. Any module can provide
backup support for any other, with no interruption or downtime. For instance, in a
redundant system you could perform full maintenance on any module without any
interruption of conditioned power to the protected IT equipment.
RimatriX Modular UPS Nominal UPS
UPSEfficiencyRating >97% 91.5%
RackPowerConsumption 60 kW 60 kW
Cost per Kilowatt Hour $0.10 $0.10
Cost to Operate per Hour $6.18 $6.56
MonthlyPowerSavings $273 saved each month
HeatDissipation(BTUsperhour) 6300 19,000
Monthly Cooling Savings* $246 saved each month
Annual Savings $6238 saved each year
Five-year Savings $31,190 saved in five years
* Cooling savings based on industry calculation of cooling costs per kW of power costs.
Reduce Energy Costs with High Efficiency
TheRimatriXModularUPSdeliversanoutstanding,
industry-leading 97% efficiency in normal operation. Even
at <50% load, where efficiency is typically much lower, this
UPSperformsmoreefficientlythancompetitors’modular
products at full load.
Even small increases in efficiency can quickly translate
into thousands of dollars. The example compares annual
and five-year energy costs for the RimatriX Modular
UPSandacompetitor’ssolution.It’seasytoseethatthe
RimatriXModularUPSpaysforitselfthroughenergyand
cooling savings alone.
100
90
80
70
20% 40% 60% 80% 100%
RimatriXModularUPS
Best-in-classUPS
NominalUPS
ReduceCoolingCostswithLowerHeatDissipation
Thehigh-efficiencyRimatriXModularUPSreducesthe
power requirements for the data center. In the example
shown,theRimatriXModularUPSreducesenergycosts
by an average of $273 per month. In addition, the high
efficiencyofaRimatriXModularUPSreducesoverallair
conditioning needs by more than one-third, multiply that
with a reduction in cooling costs by one-third; and
utility bills are further decreased by an additional $246
per month. The savings compound with the data center
sizeandthenumberofUPSproducts.Thelowheat
dissipationmeansthisUPScanbelocatedcloseto
equipment racks without a concern for creating hot
spots in the data center.
Year 1 Year 3 Year 5
®HotSyncisaregisteredtrademarkofEatonPowerwareCorporation.
102 RimatriX5 IT Solutions
Power
RimatriX Modular UPS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
EasilySet-upwithSimpleParallelConfigurationChanges
TheRimatriXModularUPSiseasytoinstall,configure,anddeploy–and
easytoexpandlater.TolinkmultipleRimatriXModularUPSmodulesinto
aparallelconfiguration,allyouneedisaRimatriXModularUPSParallel
Bus Bar – a simple kit installed in the bottom of the rack and on the back
rail. IT personnel can then simply plug additional modules into the parallel
bus bar. The system is intelligent, so it automatically detects paralleled
modules and fully configures itself for parallel operations.
SimplifyUPSInstallationandMaintenance
TheRimatriXModularUPSiseasytoinstall,configure,anddeploy.All
RimatriXModularUPS(UPSandbattery)comewithrackmountkitsfor
easy installation in standard equipment racks. In-house IT staff can
installandservicethisUPSthemselves.Addingparallelunitsforfuture
expansion is a simple, plug-and-play procedure.
TheRimatriXModularUPSbatterytraysareuser-replaceablesothatone
person, working alone, can replace the battery without disrupting data
center operations or power to protected equipment.
Advanced Battery Management
Advanced Battery Management (ABM) technology
significantly extends battery service life with a unique
three-stagechargingtechnique.TheUPSautomatically
tests battery health and provides advance notification
when preventive maintenance is needed, allowing
ample time to hot-swap batteries without ever having
to shut down connected equipment.
FlexiblyDistributePowertoRackswiththeRimatriXRackPowerModule(RPM)
PartnertheRimatriXModularUPSwithaRimatriXRackPowerModule(RPM)tocreatea
highlyflexible,adaptablepowerdeliveryarchitectureattheracklevel.TheRPMdelivers
up to 36 kW of power in an organized manner to loads of various voltages, power cords
andlayouts.The3URPMcanbedeployedinthesamerackwiththeUPSandITequip-
ment; there’s no need for a dedicated infrastructure rack. The resulting architecture has
fewer cables to manage, fewer distribution points to monitor, and greater flexibility for IT
personnel to make changes without an electrician.
Power
RimatriX Modular UPS
RimatriX5 IT Solutions 103
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
RimatriX Modular UPS
Benefits:
•Protectsmission-criticalapplicationswithinnovative
backup power technology designed specifically for
high-density environments
•Modular,scalableandflexiblebackuppower
architecture
•Conservesvaluablerackspacewith12kWof
power,includingbattery,inonly6Uofrackheight
•Accommodatesgrowthwithbuildingblock
upgrades from 12 kW to 60 kW in a single rack
•Best-in-classefficiencyreducesenergycostswith
>97% efficiency, even at loads below 40% capacity
•One-thirdtheheatdissipationofcomparable
competitive designs
•PowerwareHotSync® paralleling technology
and intelligent bypass design delivers highest
levels of reliability
•Simplifiesinstallationandmaintenancewith
plug-and-play connections and hot-swappable
batteries and electronic modules
•Parallelbatterystringsincreasesystemreliability
by decreasing the chance of battery failure
Description Input Output PartNo.
Modular3Phase 5W 5W 9971.054
Modular3Phase 5W 4W 9971.055
Modular3Phase Parallel Parallel 9971.056
Modular3Phase 5W RPM 9971.057
Description PartNo.
3UEBM 9971.058
Rail Kit 9971.059
CANBridgeParallelCard 9971.060
Modbus Card 9971.061
Industrial Relay Card 9971.062
Modem Card 9971.063
PowerVision®9971.064
42CircuitBreakerPanel 9971.065
ParallelBusBar 9961.451
WirewayforModularUPS 9961.452
RackPowerModule 9961.453
Electronic Module 9961.454
Battery Module 9961.455
SNMPCard 9970.822
Relay Card 9970.823
RimatriXModularUPSTypicalBatteryRuntimeChart(InMinutes)
Single Module Internal Battery Internal Battery + 1 EBMs + 2 EBMs + 3 EBMs + 4 EBMs
Load kW Load %
1.6 13% 55 118 183 253 329
2.4 20% 37 78.3 119 163 211
4 33% 23 46 69 94 120
6 50% 13 30 44 59 76
8 67% 9 21 32 43 54
9.6 80% 6.9 17 26 34 44
12 100% 4.8 12 20 27 34
RimatriXModularUPSTypicalBatteryRuntimeChart(ParallelUps,InMinutes)
NumberofUPS
Modules Total Load kW Configuration Internal Battery + 1 EBMs + 2 EBMs + 3 EBMs + 4 EBMs
6 60 N+1 6 15 22 29 37
5 48 N+1 6.9 17 26 34 44
4 36 N+1 18 28 37 47 47
3 24 N+1 9 21 32 43 54
2 12 N+1 13 30 44 59 76
®HotSyncisaregisteredtrademarkofEatonPowerwareCorporation.
104 RimatriX5 IT Solutions
Power
RimatriX Modular UPS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
TechnicalSpecifications1
General Characteristics
PowerRating 12kWperUPSmodule
Efficiency >97%
Heat Dissipation 371W/1266BTU/hrat100%rateload
Cooling Fan cooler, temperature microprocessor
monitored; front air entry, rear exhaust
AudibleNoise,
NormalOperation 50 dBA at 1 meter
Altitude before derating 1000 meters (3300 ft ASL)
InputCharacteristics
InputVoltage 208VAC
VoltageRange 208Vmodel:180to265VAC
Frequency Range 50 or 60 Hz, + 5 Hz
Input Current Distortion <5%withITloads(PFCpowersupplies)
InputPowerFactor >0.99withITloads(PFCpowersupplies)
Inrush Current Load dependent
Input Requirements 3-phase, 4-wire + ground
Bypass Source Same as input (single feed)
GeneratorCompatibility Fast sync slew rate for generator
synchronization
OutputCharacteristics
RateOutputVoltage 208Vmodel:180to255VAC.PhtoPh
Output Configuration 3-phase, 4-wire + ground
Output Frequency (nominal) 50 to 60 Hz auto-detection on startup
Frequency Regulation 0.1 Hz free running
LoadPowerFactorRange Lagging: 0.7, Leading 0.9
TotalOutputVoltageDistortion <3% (linear load), <5% (non-linear load)
Battery Characteristics
Battery Type VRLA–AGM
Battery Runtime (Internal) 13 minutes at 50% load
4.8 minutes at 100% load
BatteryStringVoltage 240Vdc
Battery Test Automatic battery test standard (remote
scheduling capable) Manual battery test from
front display
BatteryRechargeProfile Advanced Battery Management 3-stage
charging technology
BatteryCut-offVoltage Variablefrom1.67VPCat<5min.runtimeto
1.75VPCat>90min.runtime
Battery Low Condition Announced with alarm
Extended Battery Capability Yes,addupto4additional3Ubattery
enclosures (-34 min at 100% load, >1 hour
at 50% load)
Physical Characteristics
Dimensions (HxWxD)
UPS 10.3(6U)x17.4x26.0inches
267 x 442 x 660 mm
EBM 5.2(3U)x17.2x26inches
132 x 437 x 660 mm
Note:TotalChassisWeight
without batteries or electronics
Total Chassis Weight with
batteries or electronics
100 lbs (46 kg)
307 lbs (140 kg)
TotalUPSWeightwithout
Batteries 135 lbs (61 kg)
TotalUPSWeightwithBatteries 307 lbs (140 kg)
EBM Weight 170 lbs (77 kg)
Communications and User Interface
Software Compatibility UPSshipswithSoftwareSuiteCDcontaining
LanSafe® power management software and a
trialversionofPowerVision
X-Slot® Bays Two available for the cards listed below
OptionalX-SlotCommunicationCards
TCPI/P SNMPCard
Modbus®RTU Modbus Card
IBM eServerTM (i5TM, iSeriesTM,
or AS/400®)Relay Interface Card
N/O,N/C(drycontacts) Industrial Relay Card
Parallel CANBridgeParallelCard
Remote Monitoring Modem Card
ControlPanelLCD 2 Lines by 20 characters 4 menu-driven
interface buttons 4 status at a glance LEDs
Multi-language English standard; 20 languages available
Configuration Changes Usercapable,firmwareautoconfigures
Dry Contact Inputs One, user-configurable
Dry Contact Outputs One, user-configurable
Service
Installation Usercapable,locatedintheITracks
PreventativeMaintenance Usercapable,optionalfactoryserviceavailable
Corrective Maintenance Usercapable,optionalfactoryserviceavailable
Serviceability Features
Hot-swappable batteries
Hot-swappable electronics module
Automated internal maintenance bypass
Auto-configure firmware
Flash firmware upgradeable
Certifications
Safety 208Vmodel:UL1778,cUL
EMI 208Vmodel:FCCpart15ClassA
SurgeProtection ANSIC62.41,CatA&B
Hazardous Materials (RoHS) EUDirective2002/95/ECCategory3(4or5)
Warranty
Standard 12 months
Warranty Repair Factory depot repair or replace
ServiceSupportAgreements2
Depot PowerTrustTM Express
On-site 5x8 PowerTrustValue
On-site 7x24 PowerTrust8-,6-or2-hourresponse
OptionsandAccessories
Detachable input cord
Detachable input/output cord assembly
Detachable paralleling cord assembly
Extended Battery Modules (EBMs)
3Uoutputsub-distributionmodule
ZeroUto3Urackpowerstrips
60kWRimatriXModularUPSParallelBusBar
4-post rail kit
EnvironmentalMonitoringProbe(EMP)fortemperatureandhumiditymonitoring
X-SlotCommunicationCards(SeeCommunicationsandUserInterfacesection)
1. Due to continuing product improvement programs, specifications are subject to change without notice.
2.eNotifyremotemonitoringand7x24technicalsupportincluded.
Power
RimatriX Modular UPS
RimatriX5 IT Solutions 105
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
Benefits:
•NativeUSBandserialcommunicationsports
•AdvancedBatteryManagement(ABM)technology
doubles battery service life
•Puresinewaveoutputdeliverssmooth,continuous
power
•BuckandBoostvoltageregulationcorrects
incoming voltage fluctuations
•Enhancedbatteryrechargetimequicklyprepares
UPSforthenextpoweroutage
•NetworkTransientProtectorisolatesequipmentfrom
“backdoor”powersurgestravelingthroughnetwork
and phone lines
•Hot-swappablebatteriessimplifiedserviceand
extendservicelifeofUPS
•Includedpowermanagementsoftwareensures
data integrity
•2-YearLimitedWarranty(USandCanada)
SmallCapacityTower
Advanced Battery Management (ABM), which can
double battery service life, optimizes recharge time
for quick recovery after power outages, and provides
advanced warning of the end of useful battery life
(see Battery Chart). The batteries are hot-swappable,
allowing you to replace them without ever having to
power down the connected load and thus extending
theservicelifeoryourUPS.TheSmallCapacity
TowerUPSprovidespuresinewaveoutputduring
battery operation. It corrects incoming voltage
fluctuations so that they do not affect the performance
of the connected equipment. A CD contains power
management software, which features extensive
control and monitoring capabilities and incorporated
user friendly features including software selection
and installation. The CD includes LaneSafe power
management software.
PowerRating:500-750VA
Input/Output:110/120VAC
Voltage:220/230/240VAC
Frequency: 50/60 Hz auto-sensing
Configuration: Tower
106 RimatriX5 IT Solutions
Power
Single-PhaseUninterruptiblePowerSupply(UPS)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
Line Interactive
Rittal’sUPSresolvesthefiveprimaryproblemswith
incoming utility power – outages, sags, surges,
brownouts and over-voltage conditions – and supplies
clean, conditioned power to all connected equipment.
It also offers varying degrees of protection from other
problems, such as line noise, frequency variation,
harmonics and switching transients.
Benefits:
•Providesmorerealwattageinlessspacewitha
0.9 power factor – protecting more equipment and
leaving more room for expansion
•Two-in-oneformfactor(1000-3000VA)and
rackmount(6000VA)products
•Offersthechoiceofrackmountandtower
installation–spacesaving2Upackagingfor
1000-3000VA,3Ufor6000VAmodels–
including batteries
•Increasesbatterylifethroughmicro-processor-
controlled Advanced Battery Management (ABM)
technology
•Enablesprioritizedshutdownofnon-essential
equipment during outages to maximize backup time
for critical devices
•Increasesuptimewithhotswappablebatteriesand
electronics, without interrupting power to connected
systems(6000VAmodels)
•Completesuiteofpowermanagementsoftware
•Providesatwo-yearlimitedwarranty
PowertoMoreServersinLessSpace
1000-3000VArangeonlyoccupy2U(availablein
gray or black).
Upto6000VAofUPSpowerispackedinto3Uof
rack space.
The6000VAmodelspower30percentmoreserversin
40 percent less space compared to the leading
competitive offering.
The 0.9 power factor delivers more real output,
powersmoreserversthananotherUPSofequivalent
VArating.
Line-Interactive Design Shields Systems from
Silent Threats
Theline-interactiveUPSregulatesvoltagebyboosting
input utility voltage up or moderating it down as
necessary before allowing it to pass to the protected
equipment.
If input voltage varies as much as 20 percent over
nominal voltage or 30 percent under – which can
easily happen when running on generator power –
theUPSacceptsthisinconsistentvoltageand
delivers clean, consistent output.
Data based on tests performed by an independent
battery manufacturer.
ABM technology uses sophisticated sensing circuitry
and an innovative three-stage charging technique that
increasestheusefulservicelifeofUPSbatterieswhile
optimizing battery recharge time.
It provides up to 60 days notice of the end of useful
battery service life, to allow ample time to hot-swap
batteries without ever having to shut down connected
equipment.
Add Battery Modules for Even More
BackupCapacity
UptofourExtendedBatteryModules(EBMs)canbe
added to provide additional battery backup capac-
ity as necessary. Batteries are hot-swappable and
canbereplacedatanytimewithoutinterruptingUPS
operation and load protection.
EBMsareavailableintwoforms:2Uand3Urackmount
modules,designedtoinstallintandemwiththeUPS
for a clean look that enhances the appearance of the
data center while saving precious space.
LoadSegmentsFeatureMaximizesBattery
BackupforCriticalSystems
Independentlycontrol“LoadSegments,”whichare
groupsofreceptaclesontherearpaneloftheUPS.
During a power outage, you can shut down power
to non-critical devices (Load Segment 2), thereby
extending battery backup time available for critical
devices (Load Segment 1).
WhentheLoadSegmentsfeatureisusedwithSNMP
(SimpleNetworkManagementProtocol)connectivity
cards, users can remotely re-boot locked-up network
equipment.
Power Management Software Unifies and
Centralizes UPS Management
EveryUPScomeswithaCDthatincludesmultimedia
demonstrations, product data sheets and LanSafe
power management software for network shutdown.
PowerwareLanSafepowermanagementsoftware
givesyoucontrolandvisibilityoverallyourUPS
systems, using an intuitive, graphical interface
andSNMP.
Usingmanagementsoftware,youcansecurely
monitorUPSandbatteryperformanceoveryourLAN
or the Web, establish prioritized shutdown of network
devices and client/server applications, test all
networkedUPSsystemsfromonenode,analyze
trends and network conditions and stay informed
of potential power problems by pages and email.
EasilyServicetheUPSWithoutInterrupting
Power to Protected Systems
LEDsonthefrontpaneloftheUPSindicatethe
presence of alarm conditions, battery utilization, bad
or low batteries, site wiring faults and incoming utility
power, as well as current load levels relative to
UPScapacity.
With simple access through the front panels, users
can install new battery and electronics modules
without ever powering down connected servers or
removing the unit from the rack.
The key is an integral automatic bypass feature
(availableonVA-3000-6000VAmodels)thatallows
theUPStocontinuouslyprovidepowertocritical
equipment while you’re working on the systems.
Evenifyoupullouttheelectronics,theUPSkeeps
doing its job.
Power
Single-PhaseUninterruptiblePowerSupply(UPS)
RimatriX5 IT Solutions 107
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
ConnectivityOptionsOfferMaximumFlexibility
Connectivity options are available to suit nearly any
communication requirement. The standard unit is
equipped with RS-232 serial communications port
andabuiltinUSBport(6000VAmodels)tointerface
with power management software.
SNMPCardenablesdirectcontrolandmonitoringin
SNMP-basednetworks,plustheabilitytomonitorUPS
status and meters through a Web browser (includes
built-in switch hub).
Double Conversion
Today’s stressed electrical power distribution grids
present unique challenges for information technology
(IT)users.PowervoltagestoITequipmentcanvary
substantially from their specified value. Electricity
from local utilities is typically plagued with surges,
sags, electrical noise, harmonics, load fluctuations,
and other interferences. These anomalies can corrupt
data, cause process interruptions, and damage or
destroy connected equipment.
TheDoubleConversionUPSisconstantlyconditioning
and controlling AC output during normal operating
conditions.Unlikeothercommercially-availabletech-
nologies, a double-conversion online design assures
that in the event of a utility power failure, there is zero
delay transferring to backup power. The double-
conversion architecture incorporates both a rectifier
and inverter to completely isolate the output power
from all input anomalies. Only a true online system
suchastheDoubleConversionUPSprotects
connected equipment from all nine of the most
common power problems: outages, sags, surges,
spikes, brownouts, line noise, frequency variation,
switching transients, and harmonic distortion.
Features:
•Protectsmission-criticalapplicationsfromdowntime,
data loss and corruption, and process interruption
by providing continuous, clean power
•Securesconnectedequipmentfromdamageor
degradation caused by power anomalies
•IncreasesbatterylifethroughAdvancedBattery
Management (ABM) technology, resulting in more
uptime and fewer battery replacements
•OffersLoadSegments(on700-3000VAunits)that
enable shutdown of non-essential equipment during
power outages to extend backup power time for
critical systems
•Deliversdeploymentflexibilitywhileconserving
valuable rack space, by offering rackmount or tower
installation choices
•Ensuresdataandsystemintegritywithacomplete
power management software suite
•Providesatwo-yearlimitedwarrantyandthe
industry’s most extensive investment protection
Unify the Management of UPS
Functions and Connections
TheDoubleConversionUPS
comes complete with the Software
SuiteCD,includingSNMP-
compatible LanSafe power
management software to provide
control and visibility over multiple
UPSs.Fromacentralvantage
point, you can perform all requisite
management processes for power
protection, such as establishing
a prioritized shutdown of network
devices and client/server applica-
tions,testingallnetworkedUPSs
from one node, analyzing trends
and network conditions, and
staying informed of power
problems via email broadcasts
to mobile phones or pagers.
DesignandConnectivityOptionsOffer
MaximumFlexibility
Upto3000VAofUPSpowerispackedintoonly
twounits(2U)ofrackspace;onlythreeorfive
units(3U/5U)forthe6000VAmodels.Thestan-
dard chassis (available in gray or black) can be
deployed as a tower unit or in a rack.
Optional rack kits are available for all models. The
standard unit is equipped with an RS-232 serial
communicationsport.YoucancustomizeyourUPS
by adding X-Slot interface options for other types of
communications.
Other options available on request:
•RelayInterfaceCardprovidesdry-contactinterface
betweentheUPSandanyrelay-connecteddevice,
including the IBM eServer iSeries (AS/400) and a
variety of industrial applications
•EnvironmentalMonitoringProbe(EMP)workswith
theSNMPcard,remotelymonitoringtemperature,
humidity and the status of two contacts/sensors,
such as smoke detector and open-door detector.
(See table, page 109)
108 RimatriX5 IT Solutions
Power
Single-PhaseUninterruptiblePowerSupply(UPS)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
Power
Single-PhaseUninterruptiblePowerSupply(UPS)
RimatriX5 IT Solutions 109
 Description BatteryRun EBMRuntime Input Output Other Weight PartNo.
  Time100/50% 100% Power Rec Connections (lbs)
SmallCapacityTower120VAC 7.9"Hx5.9"Wx10.6/13.2"Deep(both120/208VACmodels)
 500VA,120VAC,Tower 5 N/A 5-15P 4x5-15R USB,DB9,2xRJ45 17 9970.817
 750VA,120VAC,19",Tower 6 N/A 5-15P 4x5-15R USB,DB9,2xRJ45 27 9970.818
SmallCapacityTower208/230VAC
 500VA,230VAC,Tower 5 N/A C14 4xC13 USB,DB9,2xRJ45 17 9970.819
 750VA,230VAC,Tower 6 N/A C14 4xC13 USB,DB9,2xRJ45 27 9970.820
LineInteractive120VAC 19.4"/19.4"/24.5"Deep
 1kVA,120VAC,19",2ULineInteractive* 7/19 33,58,82,105 5-15P 6x5-15R DB9,2xRJ45 65 7857.411
 1.5kVA,120VAC,19",2ULineInteractive* 5/13 23,49,73,96 5-15P 6x5-15R DB9,2xRJ45 65 7857.412
 3kVA,120VAC,19",2ULineInteractive,* 5/15 25,49,69,90 L5-30P 1x L5-30R, DB9, 2x RJ45 90 7857.413
6x 5-15
LineInteractive208/230VAC 19.4"/19.4"/24.5"/26"Deep
 1kVA,230VAC,19",2ULineInteractive* 7/19 33,58,82,105 C14 6xC13 DB9,2xRJ45 65 7857.414
 1.5kVA,230VAC,19",2ULineInteractive* 5/13 23,49,73,96 C14 6xC13 DB9,2xRJ45 65 7857.415
 3kVA,230VAC,19",2ULineInteractive* 5/15 25,49,69,90 C20 1xC19,9xC13 DB9,2xRJ45 90 7857.416
6kVA,230VAC,19",3ULineInteractive** 5/15 19,36,53,71 HW HW, 4x C19, SNMPExpCard 165 7857.417
4x C13
LineInteractiveExtendedBatteryModules 19.4"/24.5"/24.75"Deep 
 Ebm,1-1.5kVA,19",2ULineInteractive 65 7857.418
 Ebm,3kVA,19",2ULineInteractive 125 7857.419
 Ebm,6kVA,19",3ULineInteractive 170 7857.470
DoubleConversionOnline120VAC 19.4"/19.4"/24"Deep 
 1kVA,120VAC,19",2UDoubleConversion* 16 61,115,174,237 5-15P 6x5-15R DB9 35 7857.471
 1.5kVA,120VAC,19",2UDoubleConversion* 8 37,70,106,144 5-15P 6x5-15R DB9 50 7857.472
3kVA,120VAC,19",2UDoubleConversion* 5 25,38,54,70 L5-30 L5-30R, 2x 5-15R, DB9 85 7857.473
2x 5-20R
DoubleConversionOnline208/230VAC 19.4"/19.4"/24"/25"Deep
 1kVA,230VAC,19",2UDoubleConversion* 16/46 61,115,174,237 C14 6xC13 DB9 42 9970.821
 1.5kVA,230VAC,19",2UDoubleConversion* 8/25 37,70,106,144 C14 6xC13 DB9 35 7857.474
 3kVA,230VAC,19",2UDoubleConversion* 5/13 25,38,54,70 C20 1xC19,9xC13 DB9 50 7857.475
 6kVA,230VAC,19",5UDoubleConversion*** 10/34 30,52,76,102 L6-30P L6-30R USB,DB9 206 7857.476
DoubleConversionExtendedBatteryModule 19.4"/24"/24.75"Deep
 Ebm,1-1.5kVA,19",2UDoubleConversion 65 7857.477
 Ebm,3kVA,19",2UDoubleConversion 95 7857.478
 Ebm,6kVA,19",3UDoubleConversion 170 7857.479
ConnectivityOptionCards  
 SNMPCard 5 9970.822
Relay Card 5 9970.823
OptionalMountingHardware  
 *4Post19"Mntg1-3kVA 10 9970.824
 **4Post19"Mntg6kVALineInteractive 15 9970.825
 ***4Post19"Mntg6kVADoubleConversion 15 9970.826
 EnvironmentalMonitoringProbe 5 9970.827
 (requiresSNMPExpCard)
 AllunitsincludeLANSafepowermanagementsoftwareandserialcable
 Allunits1kVAandlargersplittheoutletsintotwoindependentlycontrolledloadsegments
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
BlackcellsindicateRittalXpressproduct.
Metered, Smart, Switched and Basic
Blade servers and high density computing power requirements continue to increase,
creating heat expansion and more challenges for managing the IT environment. To
maintaintheircompetitiveadvantage,datacentermanagersneedSNMP–basedsolutions
that monitor, track and manage servers, IT equipment and the equipment cabinet
infrastructure that houses them.
Metered PDU
MeteredPDUproductsprovidereliablepowerdistributionforallthedevicesinyourequipmentcabinet,from
5,000to20,000Watts.Meteredunitsareavailablein20or30Amps,120Voltsor208/240Voltssingle-phase,
and208Voltsthree-phase.Localinputcurrentmonitoringallowstheinstallationengineertoverifythecombined
load on the circuit or phase.
Metered PDU
Horizontal 120 V AC
Description Length Amps Watts Derated PartNo.
10x5-20R,C20P,1U,ampdisplay* 19" rackmount 20 1920 9970.723
10x5-20R,10’cord,L5-30P,1U,ampdisplay 19" rackmount 30 2880 9970.726
Horizontal 208/230 V AC
12xC13R,C20P,1U,ampdisplay* 19" rackmount 20 3328 9970.728
12xC13R,10’cord,L6-30P,1U,ampdisplay 19" rackmount 30 4992 9970.730
4xC19R,10’cord,L6-30P,1U,ampdisplay 19" rackmount 30 4992 9970.732
Vertical 120 V AC 1.75"Wx2.25"D
12x5-20R,C20P,0U,ampdisplay* 32" L 20 1920 9970.741
12x5-20R,10’cord,L5-30P,0U,ampdisplay 32" L 30 2880 9970.742
24x5-20R,C20P,0U,ampdisplay* 56" L 20 1920 9970.747
24x5-20R,10’cord,L5-30P,0U,ampdisplay 56" L 30 2880 9970.748
VerticalDualInput120VAC 3.5"Wx2.25"D
48x5-20R,10’cord,2xL5-30P,0U,ampdisplay 56" L 30 5760 9970.789
Vertical 208/230 V AC 1.75"Wx2.25"D
12xC13R,C20P,0U,ampdisplay* 32" L 20 3328 9970.743
12xC13R,10’cord,L6-30P,0U,ampdisplay 32" L 30 4992 9970.745
24xC13R,C20P,0U,ampdisplay* 56" L 20 3328 9970.749
24xC13R,10’cord,L6-30P,0U,ampdisplay 56" L 30 4992 9970.750
VerticalDualInput208/230VAC 3.5"Wx2.25"D
48xC13R,10’cord,2xC20P,0U,ampdisplay* 56" L 20 6656 9970.793
48xC13R,10’cord,2xL6-30P,0U,ampdisplay 56" L 30 9984 9970.794
Automatic Transfer Switch
8xC13R,120/208VAC,2xC20P,1U* 20 3328 9970.800
* Must choose power cord
110 RimatriX5 IT Solutions
Power
Power Distribution Units (PDU)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
Smart PDU
TheSmartPDUproductsprovidereliablepowerdistributioncombinedwithremotepowerandenvironmental
monitoring.Usethenetworkinterfacetoviewpower,temperatureandhumiditylevelsviaaWebbrowser,or
receiveSNMP–basedalarmswhenconditionsexceeddefinedthresholds.
Smart PDU
HorizontalDualInput208/230VAC
Description Length Amps Watts Derated PartNo.
12xC19R,10’cord,2xL6-30P,2U,ampdisplay,
serial&IP 19" rackmount 30 9984 9970.783
12xC19R,30A/phase,10’cord,2xL21-30P,2U,
ampdisplay,serial&IP 19" rackmount 30/phase 17280 9970.786
Vertical 208/230 V AC 1.75"Wx2.25"D
21xC13R,10’cord,L21-20P,0U,ampdisplay,
serial&IP 46" L 20/phase 5764 9970.752
24xC13R,10’cord,L21-20P,0U,ampdisplay,
serial&IP 67" L 20/phase 5764 9970.754
24xC13R,30A/phase,10’cord,L21-30P,0U,amp
display,serial&IP 67" L 30/phase 8640 9970.757
Vertical 208/230 V AC 1.75"Wx2.25"D
24xC13R,10’cord,L6-30P,0U,ampdisplay,
serial&IP 67" L 30 4992 9970.751
21xC13R,10’cord,L15-20P,0U,ampdisplay
serial&IP 46" L 20/phase 5764 9970.753
24xC13R,10’cord,L15-20P,0U,ampdisplay,
serial&IP 67" L 20/phase 5764 9970.755
24xC13R,30A/phase,10’cord,L15-30P,0U,amp
display,serial&IP 67" L 30/phase 8640 9970.758
VerticalDualInput120VAC 3.5"Wx2.25"D
48x5-20R,10’cord,2xL5-30P,0U,ampdisplay,
serial&IP 53" L 30 5760 9970.790
VerticalDualInput208/230VAC 3.5"Wx2.25"D
48xC13R,10’cord,2xL21-30P,0U,ampdisplay,
serial&IP 53" L 30/phase 17280 9970.795
48xC13R,6x5-20R,10’cord,2xL21-30P,0U,amp
display,serial&IP 53" L 30/phase 17280 9970.796
84xC13R,10’cord,2xL6-30P,0U,ampdisplay,
serial&IP 67" L 30 9984 9970.797
84xC13R,30/phase,10’cord,2xL21-30P,19",
ampdisplay,serial&IP 67" L 30/phase 17280 9970.799
EnvironmentalOption
Temp/Humidity Sensor, 118.11" (3 m) cable 9970.815
* Must choose power cord
Power
Power Distribution Units (PDU)
RimatriX5 IT Solutions 111
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
Switched PDU
SwitchedPDUproductsareFlagshipPDUswithremotemonitoringandmanagement,includingreboot
commands for connected servers and network equipment.
TheSwitchedPDUproductsprovidecompletelights-outmanagementofadatacenterandremotebranch
office.SwitchedPDUscombineremoteconfigurationandmanagementwithpowerdistributionandpowerand
environmentalmonitoring.FeaturesofswitchedPDU’sincludetheabilitytorebootasingleordual-powerserver
withonecommand,receiveSNMPalertswhenpowerorenvironmentalconditionsexceedthresholds,and
assignusersspecificaccessrightstodesignatedoutletsorgroups.OnlytheSwitchedPDUproductsprovide
the flexibility needed for all data centers and remote sites, including power requirements for high-amperage,
high-voltage;branchcircuitprotection;SSL&SSHsecurity;andSNMP-basedinputcurrentmonitoring.
Switched PDU
Horizontal 120 V AC
Description Length Amps Watts
Derated PartNo.
8x5-20R,C20P,1U,ampdisplay,serial&IP* 19" rackmount 20 1933 9970.733
8x5-20R,C20P,1U,ampdisplay,serial* 19" rackmount 20 1920 9970.734
8x5-20R,10'cord,L5-30P,1U,ampdisplay,serial&IP 19" rackmount 30 2880 9970.735
8x5-20R,10'cord,L5-30P,1U,ampdisplay,serial 19" rackmount 30 2880 9970.736
Horizontal 208/230 V AC
8xC13R,C20P,1U,ampdisplay,serial&IP* 19" rackmount 20 3328 9970.737
8xC13R,C20P,1U,ampdisplay,serial* 19" rackmount 20 3328 9970.738
8xC13R,10'cord,L6-30P,1Urackmount,serial&IP 19" rackmount 30 4992 9970.739
8xC13R,10'cord,L6-30P,1Urackmount,serial 19" rackmount 30 4492 9970.740
Vertical 120 V AC 1.75"Wx2.25"D
16x5-20R,C20P,0U,ampdisplay,serial&IP* 46" L 20 1920 9970.759
16x5-20R,C20P,0U,ampdisplay,serial* 46" L 20 1920 9970.760
16x5-20R,10'cord,L5-30P,0U,ampdisplay,serial&IP 46" L 30 2880 9970.761
16x5-20R,10'cord,L5-30P,0U,ampdisplay,serial 46" L 30 2880 9970.762
Vertical 208/230 V AC 1.75"Wx2.25"D
16xC13,C20P,0U,ampdisplay,serial&IP* 46" L 20 3328 9970.763
16xC13,C20P,0U,ampdisplay,serial* 46" L 20 3328 9970.764
16xC13,10'cord,L6-30P,0U,ampdisplay,serial&IP 46" L 30 4992 9970.765
16xC13,10'cord,L6-30P,0U,ampdisplay,serial 46" L 30 4992 9970.766
24xC13,C20P,0U,ampdisplay,serial&IP* 67" L 20 3328 9970.767
24xC13,C20P,0U,ampdisplay,serial* 67" L 20 3328 9970.768
24xC13,10'cord,L6-30P,0U,ampdisplay,serial&IP 67" L 30 4992 9970.769
24xC13,10'cord,L6-30P,0U,ampdisplay,serial 67" L 30 4992 9970.770
Vertical 208 V AC 1.75"Wx2.25"D
24xC13R,10'cord,L21-20P,0U,ampdisplay,serial&IP 67" L 20/phase 5760 9970.771
24xC13R,10'cord,L21-20P,0U,ampdisplay,serial 67" L 20/phase 5760 9970.772
24xC13R,10’cord,L15-20P,0U,ampdisplay,serial&IP 67" L 20/phase 5760 9970.773
24xC13R,10'cord,L15-20P,0U,ampdisplay,serial 67" L 20/phase 5760 9970.774
24xC13R,1x5-20R10'cord,L21-30P,0U,ampdisplay,serial&IP 67" L 30/phase 8640 9970.775
24xC13R,1x5-20R10'cord,L21-30P,0U,ampdisplay,serial 67" L 30/phase 8640 9970.776
24xC13R,1x5-20R10'cord,L15-30P,0U,ampdisplay,serial&IP 67" L 30/phase 8640 9970.777
24xC13R,1x5-20R10'cord,L15-30P,0U,ampdisplay,serial 67" L 30/phase 8640 9970.778
EnvironmentalOption
Temp/Humidity Sensor, 118.11" (3 m) cable 9970.815
* Must choose power cord
112 RimatriX5 IT Solutions
Power
Power Distribution Units (PDU)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Power
RimatriX5 IT Solutions 113
Power
Power Distribution Units (PDU)
Basic PDU
TheBasicPDUproductsprovidereliablepower
distribution for equipment racks and other data
center applications. They offer different input and
outputconnectionstodistribute110V,208V,or
230Vpoweranda20or30-Amppowerinputfeed.
CriteriaforBranchCircuitProtectionismetbythe
useofUL-listedfuses,with30Ampmodelsfeaturing
a combination of white and black outlets to easily
distinguish between each branch circuit.
Basic PDU
Horizontal/Vertical 120 V AC 1.75"Wx2.25"D
Description Length Amps Watts Derated PartNo.
12x5-20R,C20inlet,0U* 17" L 20 1920 9970.843
12x5-20R,10'cord.L5-30P,0U 17" L 30 2880 9970.844
Horizontal/Vertical 208 V AC 1.75"Wx2.25"D
12xC13R,C20inlet,0U* 17" L 20 3328 9970.845
12xC13R,10'cord.L6-30P,0U 17" L 30 4992 9970.846
Vertical 120 V AC 1.75"Wx2.25"D
24x5-20R,C20inlet,0U* 31.25" L 20 1920 9970.847
24x5-20R,10’cord.L5-30P,0U 31.25" L 30 2880 9970.848
Vertical 208 V AC 1.75"Wx2.25"D
24xC13R,C20inlet,0U* 31.25" L 20 3328 9970.849
24xC13R,10'cord.L6-30P,0U 31.25" L 30 4992 9970.850
Power Cord
PowerCordsfor20-AmpModels
Description PartNo.
177.17"(4.5m),C19/L6-20P 9970.811
98.43"(2.5m),C19/L5-20P 9970.812
98.43"(2.5m),C19/5-20P 9970.813
118.11"(3.0m),C19/5-15P 9970.814
EquipmentPowerCord
78.74" (2 m), C13/C14, pk. of 8 9970.816
Button Mount Brackets
Description PartNo.
0U,z-railbuttonmountbracket,quantity2perpackage 9971.066
0U,dualbuttonmountbracket,quantity2perpackage 9971.067
* Must choose power cord
BlackcellsindicateRittalXpressproduct.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tech Notes
114 RimatriX5 IT Solutions
Tech Notes
Inlets and Outlets NEMAandIEC
INLETS
NEMA Non-locking
5-15P 120V 15 A
5-20P 120V 20 A
NEMA Locking
L5-20P 120V 20 A
L5-30P 120V 30 A
L6-20P 230V 20 A
L6-30P 230V 30 A
IEC 60320
C20 120/230V 20 A
OUTLETS
NEMA Non-locking
5-15R 120V 10 A
5-20R 120V 15 A
IEC 60320
C13 120/230V 10 A
C19 120/230V 20 A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tech Notes
RimatriX5 IT Solutions 115
Tech Notes
Rittal TS 19" Rails
MountingStrengthwithFlexibility
0.98" (25 mm) hole patterns located
on the side and return flange
are perfect for installing cable
managementequipment,PDUs
and other accessories next to the
19" rails or between cabinets.
Solid Features
Heavy steel construction mounts
up to 3200 lb (1451 kg) of static
load on the vertical rails.
The rail system design allows
equipment to be installed over
the entire height of the 19" rail.
Umarkingsarenumberedfrom
bottom to top and are located on
the front and rear of the vertical
rails to provide easy location of
equipment.
VerticalZrailcanbefullydepth
adjustable to mount equipment
from any manufacturer.
The entire 19" rail system can be
adjusted from side to side to allow
cable management equipment
and other accessories to be
mounted beside the vertical rail, in
cabinets wider than 24" (600 mm).
The TS Server rack from
Rittal contains an innovative
19" mounting rail system
giving the strength needed
for mounting heavy equipment
while allowing flexibility for
a variety of application and
installation choices.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tech Notes
116 RimatriX5 IT Solutions
Tech Notes
TS 19" Rails
Dim A Dimension between 19" mounting surfaces on F&R rails
Dim B Dimension between 25 mm mounting flange on F&R rails
Dim C Dimension between 19" mounting surface and inside of F or R doors
Dim D Dimension between 19" mounting surface and inside of rear door
B
A
A
B
PDU Manage-IT
Zero U Mounting
The Rittal TS 19" rail system floats independently from the enclosure
frame.ThissystemprovidesroomforzeroUmountingspacebetween
rails in adjacent cabinets as well as between the 19" rails and the
enclosure sides.
Suited Enclosure Width: 24" 28" 32"
Dim A 3.5" 7.5" 11.5"
Dim B 1.7" 3.7" 5.7"
ZeroUSpace 12U 24U 36U
Factory Position Minimum1) Maximum2)
32"/800mmDepth
Dim A 25.3" (642 mm) 9.4" (238 mm) 28.2" (715 mm)
Dim B 16.1" (410 mm) 5.8" (147 mm) 19.0" (483 mm)
Dim C 2.6" (66 mm) 1.6" (41 mm) 1.6" (41 mm)
Dim D 3.5" (89 mm) 20.4" (518 mm) 1.6" (41 mm)
40"/1000mmDepth
Dim A 29.2" (742 mm) 9.4" (238 mm) 36.0" (915 mm)
Dim B 20.1" (510 mm) 5.8" (147 mm) 26.9" (683 mm)
Dim C 2.6" (66 mm) 1.6" (41 mm) 1.6" (41 mm)
Dim D 7.4" (189 mm) 28.3" (718 mm) 1.6" (41 mm)
42"/1050mmDepth
Dim A 29.2" (742 mm) 9.4" (238 mm) 38.0" (965 mm)
Dim B 20.1" (510 mm) 5.8" (147 mm) 28.8" (733 mm)
Dim C 2.6" (66 mm) 1.6" (41 mm) 1.6" (41 mm)
Dim D 9.4" (239 mm) 30.2" (768 mm) 1.6" (41 mm)
48"/1200mmDepth
Dim A 29.2" (742 mm) 9.4" (238 mm) 43.9" (1114 mm)
Dim B 20.1" (510 mm) 5.8" (147 mm) 34.7" (882 mm)
Dim C 2.6" (66 mm) 1.6" (41 mm) 1.6" (41 mm)
Dim D 15.3" (389 mm) 36.1" (918 mm) 1.6" (41 mm)
1) Minimum – Rails extended towards door in nearest position
2) Maximum – Rails extended away from door in farthest position
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Tech Notes
RimatriX5 IT Solutions 117
Notes
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indexes
118 RimatriX5 IT Solutions
PartNo. Page
2089.000 47
2092.200 47
2092.300 47
2092.500 47
2093.200 47
2094.200 47
2094.300 47
2094.500 47
2099.500 47
2237.000 25
2238.000 25
2239.000 25
2240.000 25
2250.000 25
2260.000 25
2368.010 90
2372.000 74, 90
2435.000 92
2451.000 92
2467.000 92
2468.000 92
2469.000 92
2486.500 47
2487.000 47
2488.000 47
2489.000 47
2503.200 25
2504.000 47
2504.500 47
2508.200 25
2597.000 34
3110.000 69
3110.200 68
3118.000 69
3120.000 68
3120.115 68
3124.100
61,62, 63,
64, 65, 66,
67
3124.200
61, 62, 63,
64, 65, 66,
67, 68, 96
3159.100
61, 62, 63,
64, 65, 66,
67
3171.100 70
3172.100 70
3173.100 70
3174.000 70
3181.100 70
3182.100 70
3183.100 70
3253.010 70
3273.500 64
3273.515 64
3286.100 64
3286.110 70
3286.210 64
3286.300 61, 70
3286.310 61
3286.400 62, 63, 70
3286.410 62, 63
3286.500 65, 66, 67,70
3286.510 65, 66, 67
3286.600 70
3286.700 65
PartNo. Page
3286.780 65
3286.800 66, 67
3286.870 64, 65, 66,
67, 71
3286.880 66, 67
3286.970 71
3286.980 64
3301.221 56
3301.230 56
3301.250 56
3301.310 56
3301.420 56
3301.421 56
3301.480 56
3301.490 56
3301.610 61
3301.612 62, 63, 64,
65, 66, 67
3302.100 61
3302.110 61
3303.100 61
3303.110 61
3303.500 61
3303.510 61
3304.100 62
3304.110 62
3304.500 62
3304.510 62
3305.100 62
3305.110 62
3305.500 62
3305.510 62
3321.700 70
3322.700 25, 70
3327.700 70
3328.100 63
3328.110 63
3328.500 63
3328.510 63
3329.100 63
3329.110 63
3329.500 63
3329.510 63
3359.100 65
3359.110 65
3359.500 65
3359.510 65
3382.100 65
3382.110 65
3382.500 65
3382.510 65
3383.100 66
3383.110 66
3383.500 66
3383.510 66
3384.100 67
3384.110 67
3384.500 67
3384.510 67
3385.100 67
3385.110 67
3385.500 67
3385.510 67
3636.010 50
4119.000 44
PartNo. Page
4127.000
37, 61, 62,
63, 64, 65,
66, 67
4157.000 44
4177.000 44
4178.000 44
4179.000 44
4180.000 44
4182.000 44
4532.000 45
4582.500 46
4597.000 45
4611.000 41
4634.500 41
6148.000 41
7000.390 19
7000.410 19
7000.430 19
7000.440 19
7000.450 19
7000.460 19
7000.500 19
7000.502 19
7000.505 19
7000.510 19
7000.515 19
7000.520 19
7000.525 19
7000.530 19
7000.532 19
7000.535 19
7000.560 19
7000.562 19
7000.570 19
7000.580 19
7000.590 19
7000.592 19
7000.620 20, 48
7000.640 46
7000.642 38
7000.644 38
7000.650 38
7000.652 38
7000.653 38
7000.654 38
7000.656 38
7000.663 38
7000.670 59
7000.672 41
7000.675 47
7000.676 43
7000.678 43
7000.700 26
7000.710 26
7000.720 26
7000.730 26
7000.750 26
7000.760 26
7000.770 26
7000.780 26
7000.882 18, 19
7000.885 18, 19
7000.892 18, 19
7000.895 19
PartNo. Page
7000.915 59
7000.920 59
7016.100 35
7016.110 35
7016.130 35
7051.000 50
7061.000 50
7063.710 49
7063.720 49
7063.850 51
7063.858 51
7063.860 51
7063.884 42
7063.890 51
7063.891 51
7063.895 50
7063.897 50
7064.000 50
7065.000 50
7066.000 50
7066.700 50
7072.220 34
7072.230 34
7072.240 34
7081.000 50
7111.000 34
7111.900 34
7112.000 34
7119.250 49
7119.400 49
7140.535 35
7143.035 49, 50
7144.035 49, 50
7145.035 49, 50
7145.635 50
7145.735 50
7148.035 49
7149.035 35
7149.135 35
7150.535 35
7161.000 50
7161.700 50
7163.500 51
7163.550 51
7164.035 20
7165.035 20
7166.035 20
7200.61X 74
7200.210 74, 79, 82
7200.211 74, 82
7200.213 74, 82
7200.214 74, 82
7200.215 74, 82
7200.221 74, 83
7200.344 74
7200.345 74
7200.346 74
7200.347 74
7200.371 74, 91
7200.372 74, 91
7200.420 74, 83
7200.430 74, 83
7200.440 74, 83
7200.450 74,83
PartNo. Page
7200.490 74, 90
7200.520 74, 89
7200.630 74
7200.800 92
7281.035 51
7296.000 30
7297.000 30
7298.000 30
7299.000 30
7320.000 74
7320.005 75
7320.100 74, 76, 81
7320.210 74, 77
7320.220 74, 78
7320.230 74, 78
7320.425 74, 79, 82
7320.435 74, 82
7320.440 74, 84
7320.450 74, 84
7320.470 74, 83
7320.472 83
7320.475 74, 83
7320.481 74, 83
7320.485 74, 83
7320.490 81
7320.500 77, 78, 79,
85
7320.510 77, 85
7320.520 77, 86
7320.530 77, 78, 86
7320.540 77, 85
7320.550 77, 78, 87
7320.560 77, 78, 87
7320.570 77, 78, 89
7320.580 74, 77, 78,
88
7320.590 77, 89
7320.600 74, 77, 78,
87
7320.610 77, 88
7320.615 74
7320.620 77, 78, 88
7320.630 77, 86
7320.700 74, 78, 91
7320.710 78
7320.721 78, 91
7320.730 74, 78, 94
7320.740 78, 90
7320.750 74, 78, 95
7320.760 74, 78, 95
7320.770 74, 78, 95
7320.810 74, 79
7320.812 79, 80
7320.813 80
7320.814 74, 79, 83
7320.820 81
7320.950 78
7320.960 93
7320.961 93
7320.962 93
7320.963 93
7391.000 30
7396.000 30
7400.000 30
7445.000 30
PartNo. Page
7495.000 41
7502.016 22
7502.026 22
7502.036 22
7502.046 22
7502.056 22
7502.066 22
7502.126 22
7502.136 22
7502.146 22
7502.166 22
7502.304 42
7507.000 28
7507.010 28
7507.020 28
7507.030 28
7507.100 28
7507.110 28
7507.120 28
7507.200 28
7507.210 28
7507.220 28
7507.760 29
7526.750 39
7526.760 39
7526.770 39
7526.780 39
7526.790 39
7526.800 39
7526.820 39
7526.850 39
7526.860 39
7526.964 68
7610.000 84
7611.000 84
7705.035 25, 35
7706.135 23
7709.135 23
7709.735 24
7712.135 23
7715.135 23
7715.735 24
7718.135 23
7721.135 23
7721.735 24
7825.200 37
7825.250 37
7825.260 37
7828.040 20
7828.050 20
7828.060 20
7829.150 47
7856.026 44
7857.411 109
7857.412 109
7857.413 109
7857.414 109
7857.415 109
7857.416 109
7857.417 109
7857.418 109
7857.419 109
7857.470 109
PartNumberIndex
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indexes
RimatriX5 IT Solutions 119
PartNo. Page
7857.471 109
7857.472 109
7857.473 109
7857.474 109
7857.475 109
7857.476 109
7857.477 109
7857.478 109
7857.479 109
7858.160 20
7858.488 60
7963.310 42
7963.410 20, 42
7963.510 20, 42
7963.610 20, 42
7980.000 25, 59
7980.100 59
7980.110 25
7980.148 59
8100.235 38
8126.235 38
8128.235 38
8611.020 92
8611.070 92
8611.180 92
8611.190 92
8611.200 92
8611.250 92
8611.270 92
8612.000 43
8612.020 43
8612.040 20
8612.050 20
8612.060 20, 43
8612.080 43
8612.090 43
8612.100 43
8612.120 43
8612.140 20
8612.150 20
8612.160 20, 43
8612.180 43
8612.400 45
8612.410 45
8700.000 46
8800.300 43
8800.320 43
8800.380 43
8800.490 46
8800.830 40
9960.552 40
9961.326 40
9961.328 40
9961.329 40
9961.330 40
9961.331 40
9961.332 40
9961.333 40
9961.334 40
9961.451 104
9961.452 104
9961.453 104
9961.454 104
PartNo. Page
9961.455 104
9961.868 58
9964.163 58
9967.920 48
9968.108 37
9968.109 37
9968.111 37
9968.112 37
9968.219 36
9968.385 41
9968.421 48
9968.422 48
9968.490 58
9968.491 58
9968.492 58
9968.493 58
9968.494 58
9968.495 58
9968.556 48
9968.557 48
9968.586 48
9968.587 48
9968.593 38
9968.594 38
9968.595 38
9968.596 38
9968.597 38
9968.751 41
9968.837 42
9969.309 38
9969.311 38
9969.312 38
9969.351 38
9969.352 38
9969.355 38
9969.549 97
9969.550 97
9969.561 97
9969.562 97
9969.580 23
9969.581 23
9969.582 23
9969.593 33
9969.595 33
9969.597 33
9969.598 33
9969.639 57
9969.640 57
9969.641 57
9969.658 57
9969.736 33
9969.808 14
9969.809 14
9969.810 14
9969.811 14
9969.812 14
9969.813 14
9969.814 14
9969.815 14
9969.816 15
9969.817 15
9969.818 15
9969.819 15
PartNo. Page
9969.820 15
9969.821 15
9969.822 15
9969.823 15
9969.824 15
9969.825 15
9969.826 15
9969.827 15
9969.828 15
9969.829 15
9969.830 15
9969.831 15
9969.832 15
9969.833 15
9969.834 15
9969.835 15
9969.836 15
9969.837 15
9969.838 15
9969.839 15
9969.840 15
9969.841 15
9969.842 15
9969.843 15
9969.844 15
9969.845 15
9969.846 15
9969.847 15
9969.848 15
9969.849 15
9969.850 15
9969.851 15
9969.852 15
9969.853 15
9969.854 15
9969.855 15
9969.856 15
9969.857 15
9969.858 17
9969.859 17
9969.860 17
9969.861 17
9969.862 17
9969.863 17
9969.864 17
9969.865 17
9969.866 17
9969.867 17
9969.868 17
9969.869 17
9969.874 17
9969.875 17
9969.876 17
9969.877 17
9969.878 17
9969.879 17
9969.880 17
9969.881 17
9969.882 17
9969.883 17
9969.884 17
9969.885 17
9969.886 17
PartNo. Page
9969.887 17
9969.888 17
9969.889 17
9969.890 17
9969.891 17
9969.892 17
9969.893 17
9969.894 17
9969.895 17
9969.896 17
9969.897 17
9969.898 17
9969.899 17
9969.908 15
9969.909 15
9969.910 15
9969.911 15
9969.912 15
9969.913 15
9969.914 15
9969.915 15
9969.917 38
9969.936 58
9969.937 58
9969.938 58
9969.939 58
9969.940 58
9969.941 58
9969.942 58
9969.943 58
9969.944 58
9969.945 58
9969.946 58
9969.947 58
9969.955 38
9969.956 38
9969.957 38
9969.958 38
9969.972 97
9969.973 97
9970.016 40
9970.017 40
9970.240 40
9970.241 40
9970.253 34
9970.254 34
9970.255 34
9970.256 34
9970.257 34
9970.258 34
9970.259 34
9970.260 34
9970.261 34
9970.262 34
9970.263 34
9970.264 34
9970.265 34
9970.266 34
9970.267 34
9970.268 34
9970.269 34
9970.270 34
9970.271 34
PartNo. Page
9970.723 110
9970.726 110
9970.728 110
9970.730 110
9970.732 110
9970.733 112
9970.734 112
9970.735 112
9970.736 112
9970.737 112
9970.738 112
9970.739 112
9970.740 112
9970.741 110
9970.742 110
9970.743 110
9970.745 110
9970.747 110
9970.748 110
9970.749 110
9970.750 110
9970.751 111
9970.752 111
9970.753 111
9970.754 111
9970.755 111
9970.757 111
9970.758 111
9970.759 112
9970.760 112
9970.761 112
9970.762 112
9970.763 112
9970.764 112
9970.765 112
9970.766 112
9970.767 112
9970.768 112
9970.769 112
9970.770 112
9970.771 112
9970.772 112
9970.773 112
9970.774 112
9970.775 112
9970.776 112
9970.777 112
9970.778 112
9970.783 111
9970.786 111
9970.789 110
9970.790 111
9970.793 110
9970.794 110
9970.795 111
9970.796 111
9970.797 111
9970.799 111
9970.800 110
9970.811 113
9970.812 113
9970.813 113
9970.814 113
PartNo. Page
9970.815 111, 112
9970.816 113
9970.817 109
9970.818 109
9970.819 109
9970.820 109
9970.821 109
9970.822 109
9970.823 109
9970.824 109
9970.825 109
9970.826 109
9970.827 109
9970.843 113
9970.844 113
9970.845 113
9970.846 113
9970.847 113
9970.848 113
9970.849 113
9970.850 113
9970.986 44
9970.989 40
9971.034 18
9971.037 18
9971.041 39
9971.042 39
9971.043 39
9971.044 39
9971.045 39
9971.046 39
9971.047 39
9971.048 39
9971.054 104
9971.055 104
9971.056 104
9971.057 104
9971.058 104
9971.059 104
9971.060 104
9971.061 104
9971.062 104
9971.063 104
9971.064 104
9971.065 104
9971.066 45, 113
9971.067 45, 113
9969593 33
9969594 33
9969595 33
9969596 33
9969599 33
9969600 33
9969601 33
9969697 33
9969698 33
9969927 33
9969928 33
9969929 33
9969983 33
9969984 33
PartNumberIndex
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indexes
120 RimatriX5 IT Solutions
A
Adapter Rail
 –ForPScompatibility ................................................................ 43
Add-OnCover ............................................................................... 56
Air Baffle System
Air brush baffles ...................................................................... 40
Side breathing ......................................................................... 40
Air Duct System
TopTherm roofmounted cooling unit ....................................... 71
AirflowMonitor ............................................................................... 87
AlarmSignalLamp,CMC-TC ........................................................ 90
AnalogSensorInputModule ........................................................ 86
Assembly Screws .......................................................................... 47
B
Baying Bracket .............................................................................. 46
BayingConnectors ........................................................................ 46
Baying Kit ...................................................................................... 46
BlankingPanel
Toolless .................................................................................... 40
Bolt Down Kit ................................................................................. 40
Bottom-MountedAdapter
For enclosure internal thermostat and hygrostat .................... 68
Brackets
Wallmounting ........................................................................... 25
C
CRails ........................................................................................... 25
CableEntryPanel,withbrushinsert ....................................... 25, 35
CableGuideRing .......................................................................... 34
CableManagementRail ................................................................ 36
CableManagement ....................................................................... 34
CableRouting
Across the 19" (482.6 mm) mounting level ............................. 35
CableSupport,hinged .................................................................. 51
CableTies ..................................................................................... 34
CableTroughs
19" ........................................................................................... 35
CaptiveNutsM5/M6 ...................................................................... 47
CardReader .................................................................................. 95
Casters
Transport ................................................................................. 41
Twin ......................................................................................... 41
CMC–TCMonitoringSystem
 –MasterII .................................................................................. 75
 –Configurator ............................................................................ 98
CMC–TCSensorUnits
Access unit ............................................................................. 78
 –Climateunit ............................................................................. 78
Input/Output ............................................................................ 77
CombinationRail ........................................................................... 42
CompleteGroundingKits .............................................................. 47
ComponentShelves
 –19"Configuration ..................................................................... 50
 –2U ............................................................................................ 49
Depth-variable ......................................................................... 49
For mounting frames ............................................................... 48
Telescopic slides ..................................................................... 50
ConnectionCable
Extension ................................................................................. 82
ConnectionCable
RJ 10, RJ 12 ............................................................................ 83
RJ 45 ....................................................................................... 83
Console
 –Control ..................................................................................... 97
CoverPlatesforFanPanels .......................................................... 29
Covers ........................................................................................... 56
D
Data Rack
Additional frame ...................................................................... 30
For additional data racks, see TS/TE
DigitalRelayOutputModule ......................................................... 89
DigitalSensorInputModule .......................................................... 88
DisplayUnit ................................................................................... 81
Door Operating Switch .................................................................. 37
E
Enclosure Internal Thermostat ...................................................... 69
Enclosure Lights ........................................................................... 37
EntryPanels
 –19"Cable ................................................................................. 35
ExtensionCable
RJ 10, RJ 12 ............................................................................ 83
ExtensionUnit,CMC–TC ............................................................... 89
F
Fan24VDC .................................................................................. 80
FanControlSystem(FCS) ............................................................. 79
Fan Expansion Kit
 –ELNon-NEMA3-Partenclosures ............................................ 25
Fan Expansion Kit
 –Variousfanstyles .................................................................... 59
Feet................................................................................................ 41
FilterMats
For air conditioners ................................................................. 70
FilterMats
For filter fans ........................................................................... 70
G
GSMUnitandCMC-TCSupplementaryUnit ................................ 81
H
Handles
 –ComforthandleforTS8withmasterkeyfunction ................... 91
 –Comforthandle ....................................................................... 92
 –Componentshelves ................................................................ 50
Electromagnetic lock ............................................................... 91
Transponder handle ................................................................ 94
 –UniversalInstall ....................................................................... 93
Hygrostat ....................................................................................... 69
I
Installation Kit
Depth-variable ......................................................................... 51
Interface board for TopTherm ................................................. 68, 96
InterferenceSuppressionCapacitorsforFans ............................. 90
K
Keyboard Drawer .......................................................................... 51
L
LCPReadyCabinet ....................................................................... 18
LockandPush-ButtonInserts ....................................................... 92
Index
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indexes
RimatriX5 IT Solutions 121
M
ModulePlates ................................................................................ 39
MonitoringSystem
 –ProcessingUnitII .................................................................... 76
MotionDetector,CMC-TC ............................................................. 89
MountingBracket
Button mount ........................................................................... 45
MountingBracket
 –PS ............................................................................................ 44
TS/TE ....................................................................................... 45
MountingKit .................................................................................. 44
MountingModule .......................................................................... 84
MountingPlate ........................................................................ 45, 60
MountingUnit,1U ......................................................................... 84
N
NetworkManagementSystems .................................................... 98
NylonLoop .................................................................................... 34
P
PartitionWall .................................................................................. 39
Plug-InforHPOpenView ............................................................. 98
PowerDistributionUnit(PDU)
Basic ..................................................................................... 113
 –Metered ................................................................................. 110
Smart ..................................................................................... 111
Switched ................................................................................ 112
PowerPackforPUII,FCS ............................................................ 82
ProgrammingCable ...................................................................... 83
PunchedRails
 –PS ............................................................................................ 44
R
Roof Fan ........................................................................................ 58
Roof Fan
TE ............................................................................................ 59
RoomDoorOutputModule ........................................................... 90
S
Sensor
For access .............................................................................. 86
For humidity ............................................................................ 85
For temperature ....................................................................... 85
For vandalism .......................................................................... 85
For water ................................................................................. 86
Server Fan Assembly .................................................................... 58
Server Racks
Based on Rittal TS8 ................................................................ 14
Shelves
Toolless, 19" rackmounting ..................................................... 48
Sidewalls ....................................................................................... 38
Slide Rails
 –Depth–Variable,1U ................................................................ 42
 –ELNon-NEMA3-Part .............................................................. 25
TE ............................................................................................ 42
Smoke Alarm ................................................................................. 87
Software
 –ForCMC-TC ............................................................................ 98
SpareFilterMats ........................................................................... 70
SpeedControl ............................................................................... 68
Split Rear Door Fan ...................................................................... 58
Stabilizers for Server Enclosures .................................................. 37
SupplyConnectionCable ............................................................. 80
Support Rails ................................................................................. 42
T
Toolless Shelves ............................................................................ 48
TS
 –Co–locationenclosures ........................................................... 21
 –Networkenclosures ................................................................. 16
Server enclosures ................................................................... 14
System chassis with mounting flange ..................................... 43
TE
 –Networkenclosure .................................................................. 19
U
UNuts ........................................................................................... 44
UninterruptiblePowerSupply ..................................................... 104
UniversalLockUnit ....................................................................... 94
V
VoltageMonitor .......................................................................87, 88
W
Wallmount Enclosures
 –ELNEMA123-PartEnclosures .............................................. 23
 –ELNon-NEMA3-PartEnclosures............................................ 24
 –ELNon-NEMA3-PartAccessories ......................................... 25
FlatBox .................................................................................... 27
Quickbox ................................................................................ 22
TE Wallbox and Accessories .................................................. 26
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Networkenclosures
Server enclosures
Server administration
ISP/ASPracks
Telco racks
Office solutions
Distributor racks
Wallmounted enclosures
Powermanagement
IT cooling
Monitoring
Kiosks
Rittal has one of the largest ranges of enclosures available
for immediate delivery. However, Rittal also supplies inte-
grated solutions – up to Level 4. This comprises mechanical
installation, power supply, electronic components, climate
control and central monitoring.
All in all – solutions from Rittal
For all of your requirements. Fully assembled and functional.
Wherever in the world you develop and implement solutions
for yourself and your customers, we are close at hand. The
global alliance between production, distribution and service
guarantees closeness to the customer. Worldwide!
Industrial enclosures
Power distribution
Electronicpackaging
System climate control
IT solutions
Communication systems
RittalCorporation•OneRittalPlace•SpringeldOhio45504USA•Phone:937-399-0500•TollFree:800-477-4220
E-Mail:rittal@rittal-corp.com•Website:www.rittal-corp.com
InCanada:•RittalSystemsLtd.•Phone:905-795-0777•Fax:905-795-9548•TollFree:800-399-0748
E-Mail:Rittal.Systems@Rittal.ca•Website:www.Rittal.ca
11/07_USA118_5M
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Navigation menu