15l Cc

2017-03-02

: Pdf 15L Cc 15l_cc spec products litecontrol

Open the PDF directly: View PDF PDF.
Page Count: 4

LED / 15L-CCPage 1/4 Rev. 02/22/17
© 2017 Litecontrol, a division of Hubbell Lighting, Inc. Specications subject to change without notice.
65 Spring Street Plympton, MA 02367 / Tel 781.294.0100 / Website www.litecontrol.com
15L- CC
LED Concealed Cove
Quick Find litecontrol.com 15L-CC
Ordering Guide
Performance
Nomenclature Lumens/ft W/ft Ecacy
I030 300 (min) 4.0 75
I035 350 5.0 70
I040 400 5.5 73
I045 450 6.5 69
I050 500 7.0 71
I055 550 8.0 69
I060 600 9.0 67
I065 650 9.5 68
I070 700 10.5 67
I075 750 11.5 65
I080 800 12.5 64
I085 850 13.5 63
I090 900 14.5 62
I095 950 15.5 61
I100 1000 (max) 16.0 63
(wattage may vary up to 5% from published)
Fixture Type:
Project Name:
Feature Code Options Description
Series 15L Cove-15
Mounting CC Concealed Cove
Fixture distribution AI Asymmetric Indirect
Row length (in feet) ___’ Enter in foot increments.
Note xture lengths below.
Max length in row 02 24-1/16” 610mm
03 36-1/32”, 914mm
04 48, 1219mm
06 72”, 1829mm
08 96”, 2438mm
Finish/Color C1 Matte White
Color temperature 30K 3000K
35K 3500K
40K 4000K
Output/ft I030 300 (min) see “Driver” section for limitations
(speciable in I100 1000 (max)
50 lumens/ft increments)
Driver NDM Non Dimming
D10 Osram 10% Dimming
D01 Osram 1% Dimming
LEC Hi-lume 1% EcoSystem LED driver
LHI Hi-lume 1% 3-wire LED driver
LTW Hi-lume 1% 2-wire LED driver(120V forward
phase only)
Circuiting 1C 1 Circuit
AF Alternate Fixture Switching
Voltage UNV Universal Voltage (120 or 277)
120 120 Volt
240 240 Volt
277 277 Volt
Thru-wiring W1 No Thru Wire
W2 Provide Normal and Emergency Thru Wiring*
W3 Provide Normal Thru Wiring Only
W4 Provide Emergency Thru Wiring Only
*Only applicable when specied with
emergency
Optional Features Code Options Description
Nightlight _NL Nightlight Circuit Required.
Enter quantity. 2NL = 2 nightlight circuits/row
High Performance Reector HPR High Performance Reector
Adjustable Mounting Angle AMA Adjustable Mounting Angle
Corner Wiring Kit WKC Corner Wiring Kit
Key Features
Variable Intensity technology provides a range of
speciable outputs and resulting xture wattages
Asymmetric distribution
High performance reector option
4 1/2"
(114mm)
1 3/8"
(34) 7/8"
(22)
LED / 15L-CCPage 2/4 Rev. 02/22/17
© 2017 Litecontrol, a division of Hubbell Lighting, Inc. Specications subject to change without notice.
65 Spring Street Plympton, MA 02367 / Tel 781.294.0100 / Website www.litecontrol.com
15L- CC
LED Concealed Cove
Quick Find litecontrol.com 15L-CC
Construction:
Steel housing. Ends provided with 7/8" diameter hole to accommodate
wiring. Aluminum LED module snaps into housing.
Mounting:
Install in cove (provided by others). Interior cove dimensions should allow
for a 4.5" x 1.5" cross-section. For maximum eciency, wall and ceiling above
cove should have matte surfaces with high reectances.
Fixture length:
02 (24-1/16" 610mm)
03 (36-1/32", 914mm)
04 (48", 1219mm)
06 (72", 1829mm)
08 (96", 2438mm)
Finish/Color:
Housing can be painted standard or custom colors. LED module is white.
Visit www.litecontrol.com/nishes for details.
CCT:
30K-3000K
35K-3500K
40K-4000K
Color Variation:
2 step MacAdam ellipse
Output (VI technology):
Variable Intensity (VI) technology allows precise specication of xture
output/wattage. Fixture will be programmed and labeled to specication.
See output section for available increments.
Output:
Specify in 50 lumens increments/ft within the below range:
Lumens/ft Nomenclature
Min: 300 I030
Max: 1000 I100
Driver:
NDM: Non-dimming. Fixture will be wired for xed light output.
D10: 100%-10% dimming range. Fixture will be wired for low voltage
0-10V dimming control.
D01: 100%-1% dimming range. Fixture will be wired for low voltage
0-10V dimming control.
LEC: Lutron Ecosystem compatible using Lutron A-Series driver.
100%-1% dimming range.
LHI: Lutron Hi-Lume 3 wire dimming compatible using
Lutron A-Series driver. 100%-1% dimming range.
LTW:
Lutron 2-Wire Forward Phase
*Lutron driver options available only for 300/ft, 650/ft and 1000/ft outputs.
Lutron drivers not available in 3' length xtures.
Circuiting:
1C (1 Circuit) Fixture wired for a single circuit.
AF (alternate xture switching) Fixtures wired so every other xture segment
can be separately switched/dimmed
Nightlight:
See separate LC-Nightlight spec sheet for additional details.
Details
Emergency:
Integral-not available
Inverter-compatible (by others)
Thru wiring:
See separate LC-Thruwire spec sheet for additional details.
High Performance Reector:
Specular reector and clear lens which provides greater peak intensity at a
lower angle.
Adjustable Mounting Angle:
Snap-on accessory which tilts xture to lower beam throw. May result in
direct view of LEDs-evaluate application viewing angles.
Adjustable Mounting Angle
(AMA5)
Adjustable Mounting Angle (AMA10)
Angle
of
Tilt
Ordering
Option
Fixture
Depth
(FD)
Fixture
Width
(FW)
Cove Depth
(CD) to
Completely
Conceal
Fixture at
0˚ Tilt*
Recommended
Cove
Width
(CW)
standard 1-1/2" (38 mm)
4-1/2"
(114)
1-3/4"
(44)
4-3/4"
(121)
AMA5 1-7/8" (48)
10˚ AMA10 2-1/4" (57)
*Note: When using the AMA option, refer to photometric data to ensure that
cove height does not interfere with peak output.
10˚
FW
FD CD
CW
minimum
LED / 15L-CCPage 3/4 Rev. 02/22/17
© 2017 Litecontrol, a division of Hubbell Lighting, Inc. Specications subject to change without notice.
65 Spring Street Plympton, MA 02367 / Tel 781.294.0100 / Website www.litecontrol.com
15L- CC
LED Concealed Cove
Quick Find litecontrol.com 15L-CC
Positioning at Ends and Corners
Standard Reector
Single row end
3-9" (77mm - 229mm)
Wall
Inside corner
5-8" (127mm - 203mm)
Wall
Outside corner
0-6" (0 - 152mm)
Wall
Single row end
5-11" (127mm - 279mm)
Wall
Inside corner
5-8" (127mm - 203mm)
Wall
Outside corner
0-6" (0 - 152mm)
Wall
High Performance Reector (HPR)
Corner Wiring Kit:
Pre-wires xtures for corner applications.
Recommended xture positioning:
Power feed:
Fixture intended to be wired with 3/8" exible whip.
Field accessibility:
LED boards and drivers can be accessed and removed from xture, while
installed.
CRI:
80 minimum
Rated Life:
Tested in accordance to LM79-2008 & derived from EPA TM21 calculator
L70: 160,000 (calculated per TM21 extrapolated curve)
L70: >36,288 (reported per TM21/LM80 6x's limitation)
L90: 50,000 (calculated per TM21 extrapolated curve)
L90: >36,288 (reported per TM21/LM80 6x's limitation)
Fixture weight:
2.5 lbs/ft.
Ratings:
CSA listed for damp locations. IBEW. AF of L.
Warranty:
LED boards-5 years
LED drivers (standard)-5 years
LED drivers (Lutron)-3 years
Details (continued)
LED / 15L-CCPage 4/4 Rev. 02/22/17
© 2017 Litecontrol, a division of Hubbell Lighting, Inc. Specications subject to change without notice.
65 Spring Street Plympton, MA 02367 / Tel 781.294.0100 / Website www.litecontrol.com
15L- CC
LED Concealed Cove
Quick Find litecontrol.com 15L-CC
Photometry
Fixture: 15L-CC-AI-X-02-C1-35K-I030
CCT: 3500K
Output: I030
Nominal lumens: 300 lumens/ft
Efficacy: 76.7 lm/W
Test report: 15L-CC-AI-X-02-C1-35K-I030
Fixture: 15L-CC-AI-X-02-C1-35K-I030 (HPR)
CCT: 3500K
Output: I030
Nominal lumens: 300 lumens/ft
Efficacy: 74.4 lm/W
Test report: 15L-CC-AI-X-02-C1-35K-I030 (HPR)
24.7 °C120.0 VAC 60 Hz 8.31 %
Lumens
Candela
20-25
140-145
130-135
0.0%
0.0
Zonal Lumen Summary
Zone
Polar Plot
Lumens
% of Luminaire
% of Luminaire
Lumens
0.0
0.0
0.0%
0.0%
0.0
5-10
0.0%
85-90
0.0
25-30
648
Summary of Results
0-180:
90-270:
Maximum Candela:
lm/w
76.7
135-140
15-20
10-15
Test Number 879116 - Page 3 of 5
Luminaire Efficacy:
Distribution Test Conditions
Temperature
Voltage
Current
Power
Power Factor
8.442 W
Distribution - Goniophotometer
Frequency
0.07290 A
0.964
0.0
268
#N/A
Total Lumen Output:
Spacing Criteria
0-5
0.0
0.0%
8.7%
Zone
Zone
% of Luminaire
120-125
0.0%
60-65
0.0
0.0
0.0
125-130
0.0%
65-70
0.0
8.1%
8.9%
145-150
0.0%
0.0%
0.0%
0.0%
0.0%
70-75
75-80
80-85
9.4%
9.6%
9.4%
#N/A
0.0
30-35
35-40
40-45
45-50
50-55
55-60
90-95
95-100
100-105
105-110
110-115
115-120
175-180
170-175
165-170
160-165
155-160
150-155
0.0
0.0
0.0
0.0
0.0
0.0
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
2.0
7.8
16.6
27.8
39.1
48.9
0.7%
2.0%
3.4%
4.7%
6.0%
7.1%
7.6%
6.0%
4.3%
2.6%
1.2%
0.3%
0 Deg. Plane 90 Deg. Plane 180 Deg. Plane 270 Deg. Plane
0
30
45
60
75
90
105
120
135
150
165
180
15
45
60
75
90
105
120
135
150
165
50
100
150
200
25.7 °C120.0 VAC 60 Hz 8.30 %
Lumens
Candela
20-25
140-145
130-135
0.0%
0.0
Zonal Lumen Summary
Zone
Polar Plot
Lumens
% of Luminaire
% of Luminaire
Lumens
0.0
0.0
0.0%
0.0%
0.0
5-10
0.0%
85-90
0.0
25-30
627
Summary of Results
0-180:
90-270:
Maximum Candela:
lm/w
74.4
135-140
15-20
10-15
Test Number 879114 - Page 3 of 5
Luminaire Efficacy:
Distribution Test Conditions
Temperature
Voltage
Current
Power
Power Factor
8.439 W
Distribution - Goniophotometer
Frequency
0.07290 A
0.964
0.0
438
#N/A
Total Lumen Output:
Spacing Criteria
0-5
0.0
0.0%
10.8%
Zone
Zone
% of Luminaire
120-125
0.0%
60-65
0.0
0.0
0.0
125-130
0.0%
65-70
0.0
6.6%
7.6%
145-150
0.0%
0.0%
0.0%
0.0%
0.0%
70-75
75-80
80-85
10.3%
9.3%
8.5%
#N/A
0.0
30-35
35-40
40-45
45-50
50-55
55-60
90-95
95-100
100-105
105-110
110-115
115-120
175-180
170-175
165-170
160-165
155-160
150-155
0.0
0.0
0.0
0.0
0.0
0.0
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.7
6.8
26.5
45.2
56.6
64.5
0.3%
1.0%
1.8%
2.7%
3.9%
5.3%
10.3%
9.0%
7.2%
4.2%
1.1%
0.1%
0 Deg. Plane 90 Deg. Plane 180 Deg. Plane 270 Deg. Plane
0
30
45
60
75
90
105
120
135
150
165
180
15
45
60
75
90
105
120
135
150
165
100
200
300
Zonal Lumens
Zone Lumens % Lamp %
0-30 0 0
0-40 0 0
0-60 0 0
0-90 0 0
90-120 142 22
90-130 259 40
90-150 492 76
90 -180 648 100
0-180 648 100
Zonal Lumens
Zone Lumens % Lamp %
0-30 0 0
0-40 0 0
0-60 0 0
0-90 0 0
90-120 200 32
90-130 332 53
90-150 533 85
90 -180 628 100
0-180 628 100