Rittal Climate Control Catalog 161407
2016-08-16
: Pdf 161407-Catalog 161407-Catalog B3 unilog
Open the PDF directly: View PDF .
Page Count: 140 [warning: Documents this large are best viewed by clicking the View PDF Link!]
Rittal the Authority for Comprehensive Climate Control
R
The Future of
Climate Control
2 Rittal the Authority in Climate Control
Focus On The Future
Rittal climate control guarantees progress
ENVIRONMENTALLY FRIENDLY
COOLING TECHNOLOGY
History of successes for Rittal innovations
1983
Beginning of Rittal’s enclosure climate control production.
The focus of our development and design at the time:
Reducing strain on the environment with energy efficient and highly
effective equipment.
1988
First enclosure air conditioner equipped with microcontroller.
1992
First air conditioner without the coolant R22/R12, Pro Ozone.
1994
First Design-air conditioner line, with updated microcontroller.
2002
Rittal TopTherm, the new generation of air conditioners and the
beginning of Rittal’s liquid cooling concept.
Rittal’s CMC remote monitoring system provides surveillance of
air conditioners and chiller systems via the Internet.
Experience – Research – Development
Constant communication with our global customers, combined with
Rittal’s vast experience with climate control research and
development, create
many options for your specific application.
Rittal develops customized solutions, with the aid of its own
accredited laboratories, computer supported flow models (CFD)
and infrared-thermography.
Many companies talk about the future, Rittal is shaping it.
We have chosen a forward-thinking approach for climate
control development and environmental protection is the
focus of our research.
Rittal has been the trendsetter in the climate control market
for many years.
Since 1992
Pro Ozone
has become the global term for envi-
ronmentally friendly cooling technology. At one time the only
environmental issue was to replace the coolants R22 and
R12, that were destroying the ozone layer. Now we are deal-
ing with the greenhouse effect, a result of the ozone layer
destruction. Rittal is searching for ways to replace the cool-
ant R134a and reduce emissions.
During the operation of an air conditioner only 3% of the
CO
2
-creation in the environment is the result of the coolant,
the other 97% is the result of the electric power consumption.
All Rittal climate control products have been
consistently
designed for
energy-efficiency.
Our newest feature,
Rittal Liquid Cooling
offers an innova-
tive approach to enclosure cooling with effective and pro-
gressive climate control options.
3Rittal the Authority in Climate Control
Better selection, better quality, better value
Rittal has
expanded
the
successful TopTherm program
with the
addition of several
new air conditioners
and
heat exchangers.
Our system wide cross-platform concept makes a variety of cost
effective solutions possible. It facilitates special solutions for all sorts
of individual needs and applications.
New liquid cooling concepts
New performance standards for CPUs, network components, hard
drives and other hardware have been set.
Liquid can absorb
and
dissipate
a thousand times more heat in comparison to air
by
volume, therefore Rittal has established new dimensions in its
development of cooling technology.
Rittal looks to the future.
4 Rittal the Authority in Climate Control
Perfect Climate, Stable Performance
Customized climate control
Rittal’s climate control offers perfect solutions for forward-
thinking and comprehensive process control. Perfectly coor-
dinated
enclosure systems, climate control technology
and remote monitoring systems
provide state-of-the-art
security and availability for your production facility.
Rittal is able to develop customized climate control solutions
for virtually any application.
Identical installation cutouts for a variety of air conditioners,
heat exchangers and fans, make the installation of climate
control simple and
adaptable to your individual cooling
needs.
Rittal climate control –
We insist on top quality, great value, environmentally friendly
and highly effective equipment.
Rittal TopTherm air conditioners,
in a performance class by itself.
Rittal TopTherm air conditioners are built to the highest
standards. Functional design, high degree of effectiveness,
targeted cold air routing, and centalized monitoring make
TopTherm air conditioners top performers.
Technology: Ideal combination of comfort, safety and flexibility.
Cooling performance: Generated and distributed effectively.
Design: Form follows function, aesthetically pleasing and an
eye-catching design.
Service: Layout, project planning, and thermal analysis.
Chiller systems multitask in cooling technology
The efficiency of chillers is ideal for applications where high cooling
requirements exist. Chillers apply a comprehensive approach to
process, machine and fluid cooling. Chillers are able to dissipate
large heat loads with air/water heat exchangers and cooling
elements from enclosures and components.
All inclusive, service: Project planning, prototypes, quoting,
installation and start-up and service agreement.
Cost advantage: Globally available off-the-shelf components
make economizing easy.
5Rittal the Authority in Climate Control
Air/air heat exchangers
use the cooler ambient air to effectively
dissipate heat from the enclosure by using hermetically sealed air
circuits (using a counter current, or cross-flow concept). Ambient air
and dust are unable to ingress the enclosure.
Air/water heat exchangers
cool the enclosure interior by integration
into an existing cooling water cycle or connection to a chiller.
This makes efficient dissipation of high heat loads under the most
extreme conditions possible.
Filter fans
with a very low profile design, low noise and high output.
Prerequisite: cool, relatively clean ambient air.
19˝ Climate control:
Rack-mounted air conditioners, rack-mounted
fans and blowers. Cooling is most effective when installed directly
below the electronic equipment.
Heaters
prevent the formation of condensation. This is especially
valuable for outside locations or unheated rooms.
Climate control accessories
make achieving the perfect climate
solution even easier.
6 Climate Control
Climate Control
Air Conditioners From page 22
Features............................................................................................ 22
Climate Controlled Enclosures
Enclosures, single door ....................................................................24
Enclosures, twin door .......................................................................25
Climate Control Doors
For 600 mm (26.2˝) wide TS8 modular enclosures,
Useful cooling capacity 1250/1500 W (4269/5738 BTU) .................. 26
For 800 mm (31.5˝) wide TS8 modular enclosures,
Useful cooling capacity 1510 W (5150 BTU) .................................... 27
For 600 mm (26.2˝) wide TS8 modular enclosures,
Useful cooling capacity 2010/2550 W (6865/8709 BTU) .................. 28
For 1200 mm (47.2˝) wide TS8 modular enclosures,
Useful cooling capacity 1250/1680 W (4269/5738 BTU) .................. 29
For 1200 mm (47.2˝) wide TS8 modular enclosures,
Useful cooling capacity 2010/2550 W (6865/8708 BTU) .................. 30
Climate Control Sidewalls
For installation in 600 mm (26.2˝) deep TS8 modular enclosures .... 31
Roof-Mounted Air Conditioners
Useful cooling capacity 510/810 W (1742/2766 BTU)...................... 32
Useful cooling capacity 1080 W (3688 BTU).................................... 33
Useful cooling capacity 1200 W (4098 BTU).................................... 34
Useful cooling capacity 1520/2130 W (5191/7274 BTU).................. 35
Useful cooling capacity 3300/4200 W (11,270/14,344 BTU)............ 36
Wall-Mounted Air Conditioners
VIP small air conditioners,
Useful cooling capacity 270 W (922 BTU) ....................................... 37
Mini air conditioner in horizontal format,
Useful cooling capacity 320 W (1093 BTU)...................................... 38
Useful cooling capacity 320/610 W (1093/2080 BTU)...................... 39
Useful cooling capacity 780 W (2664 BTU)...................................... 40
Useful cooling capacity 1060/1510 W (3620/5150 BTU).................. 41
Useful cooling capacity 2350/2750 W (8026/9392 BTU).................. 42
Useful cooling capacity 4400 W (15,027 BTU)................................. 43
Slimline, useful cooling capacity 1500 W (5123 BTU)...................... 44
Design NEMA 4X.............................................................................. 45
Chiller Systems From page 48
Features............................................................................................ 48
Chiller Systems
Mini ................................................................................................... 50
Mini, for wall-mounting...................................................................... 52
Freestanding enclosure .................................................................... 53
Freestanding enclosure for oil ..........................................................55
In a TS8 modular enclosure system ................................................. 57
In an Industrial enclosure.................................................................. 59
Immersible chiller systems for oil ..................................................... 60
Immersible chiller systems for emulsion .......................................... 63
Heat Exchangers From page 66
Features............................................................................................ 66
Air/Water Heat Exchangers
Micro, for wall-mounting.................................................................... 68
Wall-mounted.................................................................................... 69
Roof-mounted................................................................................... 72
As a sidewall for 600 mm (26.2˝) deep TS8 modular enclosures..... 74
Air/Air Heat Exchangers
Wall-mounted.................................................................................... 75
Filter Fan Units From page 78
Features............................................................................................ 78
Filter Fan Unit
Air displacement 12/39 – 106/424 cfm .............................................79
Filter Fan Unit – EMC
Air displacement 12/71 – 106/433 cfm .............................................83
Climate Control Tailored To Enclosures From page 85
Features............................................................................................ 85
Rack-Mounted Air Conditioners for 482.6 mm (19˝) ..................... 87
Rack-Mounted Fans for 482.6 mm (19˝) ......................................... 88
Centrifugal Fans ............................................................................. 89
Fan Systems.................................................................................... 90
Heaters From page 97
Features............................................................................................ 97
Enclosure Heaters
Continuous thermal output 10 – 300 W (34 – 1025 BTU)................. 98
For CS outdoor enclosures, continuous thermal capacity
600/1000 W (2049/3415 BTU).......................................................... 99
Accessories For Climate Control From page 100
Features.......................................................................................... 100
Accessories for Climate Control
Air routing .......................................................................................101
Regulation/control .......................................................................... 103
General........................................................................................... 107
Filter mats....................................................................................... 111
Liquid Cooling From page 114
Features.......................................................................................... 114
Rittal Liquid Cooling Package ..................................................... 115 Rack-Mounted Chiller System..................................................... 116
Power Cooling System (PCS) ...................................................... 117
Overview From page 7 – 21
Climate Control Overview
7Climate Control
A
4
.
Climate Control Overview
Rittal’s climate control creates the desired
ambient conditions for virtually any
application, including sensitive electronics.
A wide range of air conditioners, chillers, heat
exchangers, filter fans and enclosure heaters
protect against adverse physical and thermal
conditions. Rittal also offers a wide range of
system accessories.
Enhanced operational reliability and a longer
service life for electronics
●Climate controlled enclosure systems
●Air conditioners
●Chillers
●Heat exchangers
●Filter fan units
●Roof-mounted fans
●Rack-mounted climate control
●Enclosure heaters
●Cooling
Detailed information can be found on
pages 22 – 118
or on our website: www.rittal-corp.com
The current status of certifications
may be found on our website: www.rittal-corp.com
4.1 Climate Controlled Enclosures
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No.
SK
Certifications
Page
UL CUL DIN GS
1250
(4260)
1800 x 600 x 600 (70.9 x 23.6 x 23.6) 230, 50/60 8687.100 24
2000 x 600 x 600 (78.7 x 23.6 x 23.6) 8607.100 24
1800 x 600 x 600 (70.9 x 23.6 x 23.6) 400, 2~,
50/60
8687.840 24
2000 x 600 x 600 (78.7 x 23.6 x 23.6) 8607.840 24
1510
(5150)
1800 x 800 x 600 (70.9 x 31.5 x 23.6) 230,
50/60
8887.150 24
2000 x 800 x 600 (78.7 x 31.5 x 23.6) 8807.100 24
1800 x 800 x 600 (70.9 x 31.5 x 23.6) 400, 2~,
50/60
8887.140 24
2000 x 800 x 600 (78.7 x 31.5 x 23.6) 8807.140 24
2010
(6860)
1800 x 1200 x 600 (70.9 x 47.2 x 23.6)
230,
50/60
8287.170 25
8807.180 25
2000 x 1200 x 600 (78.7 x 47.2 x 23.6) 8207.170 25
8207.180 25
2550
(8700)
1800 x 1200 x 600 (70.9 x 47.2 x 23.6) 400, 3~,
50/60
8807.260 25
2000 x 1200 x 600 (78.7 x 47.2 x 23.6) 8807.250 25
Delivery times available on request.
4.1 Climate Control Doors
For single-door TS8 modular enclosures with thermostat
Useful
cooling
capacity
W (BTU)
For modular enclosure
dimensions
H x W mm (inches)
Voltage
V, Hz Part No.
SK
Certifications
Page
UL CUL DIN GS
1250
(4260)
1800 x 600 (70.9 x 23.6) 230,
50/60
3306.8801) 26
2000 x 600 (78.7 x 23.6) 3306.8001) 26
1800 x 600 (70.9 x 23.6) 400, 2~,
50/60
3306.8841) 26
2000 x 600 (78.7 x 23.6) 3306.8401) 26
1680
(5740)
1800 x 600 (70.9 x 23.6) 230,
50/60
3307.8801) 26
2000 x 600 (78.7 x 23.6) 3307.8001) 26
1800 x 600 (70.9 x 23.6) 400, 2~,
50/60
3307.8901) 26
2000 x 600 (78.7 x 23.6) 3307.840 26
1510
(5150)
1800 x 800 (70.9 x 31.5) 230,
50/60
3308.8801) 27
2000 x 800 (78.7 x 31.5) 3308.8001) 27
1800 x 800 (70.9 x 31.5) 400, 2~,
50/60
3308.8841) 27
2000 x 800 (78.7 x 31.5) 3308.8401) 27
2010
(6860)
1800 x 600 (70.9 x 23.6) 230,
50/60
3309.8801) 28
2000 x 600 (78.7 x 23.6) 3309.800 28
1800 x 600 (70.9 x 23.6) 400, 2~,
50/60
3309.8841) 28
2000 x 600 (78.7 x 23.6) 3309.8401) 28
2550
(8700)
1800 x 600 (70.9 x 23.6) 400, 3~,
50/60
3310.8801) 28
2000 x 600 (78.7 x 23.6) 3310.800 28
1) Delivery times available on request.
Climate Control Overview
8 Climate Control
A
4.
Climate Control Overview
4.1 Climate Control Doors
For single-door TS8 modular enclosures with microcontroller
Useful
cooling
capacity
W (BTU)
For modular enclosure
dimensions
H x W mm (inches)
Voltage
V, Hz Part No.
SK
Certifications
Page
UL CUL DIN GS
1250
(4260)
1800 x 600 (70.9 x 23.6) 230,
50/60
3306.5801) 26
2000 x 600 (78.7 x 23.6) 3306.5001) 26
1800 x 600 (70.9 x 23.6) 400, 2~,
50/60
3306.5901) 26
2000 x 600 (78.7 x 23.6) 3306.5401) 26
1680
(5740)
1800 x 600 (70.9 x 23.6) 230,
50/60
3307.5801) 26
2000 x 600 (78.7 x 23.6) 3307.5001) 26
1800 x 600 (70.9 x 23.6) 400, 2~,
50/60
3307.5901) 26
2000 x 600 (78.7 x 23.6) 3307.5401) 26
1510
(5150)
1800 x 800 (70.9 x 31.5) 230,
50/60
3308.5801) 27
2000 x 800 (78.7 x 31.5) 3308.500 27
1800 x 800 (70.9 x 31.5) 400, 2~,
50/60
3308.5901) 27
2000 x 800 (78.7 x 31.5) 3308.540 27
2010
(6860)
1800 x 600 (70.9 x 23.6) 230,
50/60
3309.5801) 28
2000 x 600 (78.7 x 23.6) 3309.500 28
1800 x 600 (70.9 x 23.6) 400, 2~,
50/60
3309.5901) 28
2000 x 600 (78.7 x 23.6) 3309.540 28
2550
(8700)
1800 x 600 (70.9 x 23.6) 400, 3~,
50/60
3310.5801) 28
2000 x 600 (78.7 x 23.6) 3310.5001) 28
1) Delivery times available on request.
For two-door TS8 modular enclosures
Useful
cooling
capacity
W (BTU)
For modular
enclosure
dimensions
H x W
mm (inches)
Voltage
V, Hz
Device
position
Part No. SK Certifications
Page
With
thermostat
With
micro-
controller
UL CUL DIN GS
1250
(4260)
1800 x 1200
(70.9 x 47.2)
230, 50/60
right
3306.250 3306.550 29
400, 2~, 50/60 3306.450 3306.650 29
2000 x 1200
(78.7 x 47.2)
230, 50/60 3306.210 3306.510 29
400, 2~, 50/60 3306.410 3306.610 29
1800 x 1200
(70.9 x 47.2)
230, 50/60
left
3306.270 3306.570 29
400, 2~, 50/60 3306.470 3306.670 29
2000 x 1200
(78.7 x 47.2)
230, 50/60 3306.230 3306.530 29
400, 2~, 50/60 3306.430 3306.630 29
1680
(5740)
1800 x 1200
(70.9 x 47.2)
230, 50/60
right
3307.250 3307.550 29
400, 2~, 50/60 3307.450 3307.650 29
2000 x 1200
(78.7 x 47.2)
230, 50/60 3307.210 3307.510 29
400, 2~, 50/60 3307.410 3307.610 29
1800 x 1200
(70.9 x 47.2)
230, 50/60
left
3307.270 3307.570 29
400, 2~, 50/60 3307.470 3307.670 29
2000 x 1200
(78.7 x 47.2)
230, 50/60 3307.230 3307.530 29
400, 2~, 50/60 3307.430 3307.630 29
2010
(6860)
1800 x 1200
(70.9 x 47.2)
230, 50/60
right
3309.170 3309.570 30
400, 2~, 50/60 3309.470 3309.670 30
2000 x 1200
(78.7 x 47.2)
230, 50/60 3309.120 3309.520 30
400, 2~, 50/60 3309.420 3309.620 30
1800 x 1200
(70.9 x 47.2)
230, 50/60
left
3309.210 3309.510 30
400, 2~, 50/60 3309.410 3309.610 30
2000 x 1200
(78.7 x 47.2)
230, 50/60 3309.140 3309.530 30
400, 2~, 50/60 3309.440 3309.640 30
2550
(8700)
1800 x 1200
(70.9 x 47.2) 400, 3~,
50/60 right
3310.250 3310.650 30
2000 x 1200
(78.7 x 47.2) 3310.230 3310.630 30
1800 x 1200
(70.9 x 47.2) 400, 3~,
50/60 left
3310.150 3310.550 30
2000 x 1200
(78.7 x 47.2) 3310.130 3310.530 30
Delivery times available on request.
Climate Control Overview
9Climate Control
A
4.
Climate Control Overview
4.1 Climate Control Sidewalls
For TS8 modular enclosures
Useful cooling capacity
W (BTU)
For modular enclosure
dimensions
H x W mm (inches)
Voltage
V, Hz Part No. SK Page
1200
(4100)
1800 x 600
(70.9 x 23.6) 230,
50/60
3331.116 31
2000 x 600
(78.7 x 23.6) 3331.316 31
1800 x 600
(70.9 x 23.6) 400, 2~,
50/60
3331.1401) 31
2000 x 600
(78.7 x 23.6) 3331.3401) 31
1450
(4950)
1800 x 600
(70.9 x 23.6) 230,
50/60
3331.2161) 31
2000 x 600
(78.7 x 23.6) 3331.416 31
1800 x 600
(70.9 x 23.6) 400, 2~,
50/60
3331.2401) 31
2000 x 600
(78.7 x 23.6) 3331.4401) 31
1) Delivery times available on request.
4.1 TopTherm Roof-Mounted Air Conditioners
Useful cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK Certifications
Page
With basic
controller
With comfort
controller UL CUL DIN GS
510
(1740)
415 x 597 x 375
(16.3 x 23.5 x 14.8)
230, 50/60 3382.100 3382.500 32
115, 50/60 3382.110 3382.510 32
810
(2765)
415 x 597 x 375
(16.3 x 23.5 x 14.8)
230, 50/60 3359.100 3359.500 32
115, 50/60 3359.110 3359.510 32
400, 2~, 50/60 3359.140 3359.540 32
1080
(3690)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3383.100 3383.500 33
115, 50/60 3383.110 3383.510 33
400, 2~, 50/60 3383.140 3383.540 33
1520
(5190)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3384.100 3384.500 35
115, 50/60 3384.110 3384.510 35
400, 2~, 50/60 3384.140 3384.540 35
2130
(7270)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3385.100 3385.500 35
115, 50/60 3385.110 3385.510 35
400, 2~, 50/60 3385.140 3385.540 35
3300
(11,270)
470 x 796 x 580
(18.5 x 31.3 x 22.8)
400, 3~, 50
460, 3~, 60 3386.140 3386.540 36
4200
(14,344)
470 x 796 x 580
(18.5 x 31.3 x 22.8)
400, 3~, 50
460, 3~, 60 3387.140 3387.540 36
Roof-mounted air conditioners in stainless steel version, see page 10.
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
4.1 TopTherm Roof-Mounted Air Conditioners
For the office sector
Useful cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
1200
(4100)
415 x 597 x 510
(16.3 x 23.5 x 20.1)
115, 50/60 3273.5151) 34
230, 50/60 3273.500 34
1) Delivery times available on request.
Climate Control Overview
10 Climate Control
A
4.
Climate Control Overview
4.1 TopTherm Roof-Mounted Air Conditioners
Stainless steel
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK Certifications
Page
With basic
controller
With comfort
controller UL CUL DIN GS
510
(1740)
415 x 597 x 375
(16.3 x 23.5 x 14.8)
230, 50/60 3382.200 3382.600 32
115, 50/60 3382.210 3382.610 32
810
(2770)
415 x 597 x 375
(16.3 x 23.5 x 14.8)
230, 50/60 3359.200 3359.600 32
115, 50/60 3359.210 3359.610 32
400, 2~, 50/60 3359.240 3359.640 32
1080
(3690)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3383.200 3383.600 33
115, 50/60 3383.210 3383.610 33
400, 2~, 50/60 3383.240 3383.640 33
1520
(5190)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3384.200 3384.600 35
115, 50/60 3384.210 3384.610 35
400, 2~, 50/60 3384.240 3384.640 35
2130
(7274)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3385.200 3385.600 35
115, 50/60 3385.210 3385.610 35
400, 2~, 50/60 3385.240 3385.640 35
3300
(11,270)
470 x 796 x 580
(18.5 x 31.3 x 22.8)
400, 3~, 50
460, 3~, 60 3386.240 3386.640 36
4200
(14,344)
470 x 796 x 580
(18.5 x 31.3 x 22.8)
400, 3~, 50
460, 3~, 60 3387.240 3387.640 36
Delivery times available on request.
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
4.1 Wall-mounted Air Conditioners
VIP small air conditioners
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Condenser
design Part No.
SK
Certifications
Page
UL CUL DIN GS
270
(920)
353.5 x 526 x 105
(13.9 x 20.7 x 4.1) 230, 50/60 left 3201.100 37
right 3202.100 37
4.1 TopTherm Wall-Mounted Air Conditioners
Mini air conditioner, in horizontal format
Useful cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Certifications
Page
UL CUL DIN GS
320
(1090)
340 x 525 x 153
(13.4 x 20.7 x 6.0)
230, 50/60 3302.300 38
115, 60 3302.310 38
Climate Control Overview
11Climate Control
A
4.
Climate Control Overview
4.1 TopTherm Wall-Mounted Air Conditioners
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK Certifications
Page
With basic
controller
With comfort
controller UL CUL DIN GS
320
(1090)
550 x 280 x 140
(21.7 x 11.0 x 5.5)
230, 50/60 3302.100 – 39
115, 60 3302.110 – 39
610
(2080)
550 x 280 x 200
(21.7 x 11.0 x 7.9)
230, 50/60 3303.100 3303.500 39
115, 60 3303.110 3303.510 39
780
(2665)
550 x 280 x 280
(21.7 x 11.0 x 11.0)
230, 50/60 3361.100 3361.500 40
115, 60 3361.110 3361.510 40
400, 2~, 50/60 3361.140 3361.540 40
1060
(3600)
950 x 400 x 260
(37.4 x 15.7 x 10.2)
230, 50/60 3304.100 3304.500 41
115, 50/60 3304.110 3304.510 41
400, 3~, 50
460, 3~, 60 3304.140 3304.540 41
1510
(5150)
950 x 400 x 260
(37.4 x 15.7 x 10.2)
230, 50/60 3305.100 3305.500 41
115, 50/60 3305.110 3305.510 41
400, 3~, 50
460, 3~, 60 3305.140 3305.540 41
2350
(8000)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
230, 50/60 3328.100 3328.500 42
115, 50/60 3328.110 3328.510 42
400, 3~, 50
460, 3~, 60 3328.140 3328.540 42
2750
(9390)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
230, 50/60 3329.100 3329.500 42
115, 50/60 3329.110 3329.510 42
400, 3~, 50
460, 3~, 60 3329.140 3329.540 42
4400
(15,000)
1580 x 500 x 340
(62.2 x 19.7 x 13.4)
400, 3~, 50
460, 3~, 60 3332.140 3332.540 43
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Stainless steel
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK Certifications
Page
With basic
controller
With comfort
controller UL CUL DIN GS
320
(1090)
550 x 280 x 140
(21.7 x 11.0 x 5.5)
230, 50/60 3302.200 – 39
115, 60 3302.210 – 39
610
(2080)
550 x 280 x 200
(21.7 x 11.0 x 7.9)
230, 50/60 3303.200 3303.600 39
115, 60 3303.210 3303.610 39
780
(2665)
550 x 280 x 280
(21.7 x 11.0 x 11.0)
230, 50/60 3361.200 3361.600 40
115, 60 3361.210 3361.610 40
400, 2~, 50/60 3361.240 3361.640 40
1060
(3600)
950 x 400 x 260
(37.4 x 15.7 x 10.2)
230, 50/60 3304.200 3304.600 41
115, 50/60 3304.210 3304.610 41
400, 3~, 50
460, 3~, 60 3304.240 3304.640 41
1510
(5150)
950 x 400 x 260
(37.4 x 15.7 x 10.2)
230, 50/60 3305.200 3305.600 41
115, 50/60 3305.210 3305.610 41
400, 3~, 50
460, 3~, 60 3305.240 3305.640 41
2350
(8000)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
230, 50/60 3328.200 3328.600 42
115, 50/60 3328.210 3328.610 42
400, 3~, 50
460, 3~, 60 3328.240 3328.640 42
2750
(9390)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
230, 50/60 3329.200 3329.600 42
115, 50/60 3329.210 3329.610 42
400, 3~, 50
460, 3~, 60 3329.240 3329.640 42
4400
(15,000)
1580 x 500 x 340
(62.2 x 19.7 x 13.4)
400, 3~, 50
460, 3~, 60 3332.240 3332.640 43
Delivery times available on request.
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Climate Control Overview
12 Climate Control
A
4.
Climate Control Overview
4.1 TopTherm Wall-Mounted Air Conditioners
Slimline
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK
Page
With basic
controller
With comfort
controller
1500
(5123)
1580 x 450 x 165
(62.2 x 17.7 x 6.5)
230, 50/60 3377.1001) 3377.5001) 44
115, 50/60 3377.1101) 3377.5101) 44
400/460, 3~, 50/60 3377.1401) 3377.5401) 44
1500
(5123)
1580 x 450 x 195
(62.2 x 17.7 x 7.7)
230, 50/60 3366.100 3366.500 44
115, 50/60 3366.110 3366.510 44
400/460, 3~, 50/60 3366.140 3366.540 44
1) Delivery times available on request.
Slimline, Stainless steel
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK
Page
With basic
controller
With comfort
controller
1500
(5123)
1580 x 450 x 165
(62.2 x 17.7 x 6.5)
230, 50/60 3377.200 3377.600 44
115, 50/60 3377.210 3377.610 44
400/460, 3~, 50/60 3377.240 3377.640 44
1500
(5123)
1580 x 450 x 195
(62.2 x 17.7 x 7.7)
230, 50/60 3366.200 3366.600 44
115, 50/60 3366.210 3366.610 44
400/460, 3~, 50/60 3366.240 3366.640 44
Delivery times available on request.
4.1 TopTherm Wall-Mounted Air Conditioners
NEMA 4X version
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK Certifications
Page
With basic
controller
With comfort
controller UL CUL DIN GS
610
(2080)
550 x 280 x 200
(21.7 x 11.0 x 7.9)
230, 50/60 3303.104 3303.504 45
115, 50/60 3303.114 3303.514 45
1060
(3620)
950 x 400 x 260
(37.4 x 15.7 x 10.2)
230, 50/60 3304.104 3304.504 45
115, 50/60 3304.114 3304.514 45
400, 3~, 50
460, 3~, 60 3304.144 3304.544 45
1510
(5150)
950 x 400 x 260
(37.4 x 15.7 x 10.2)
230, 50/60 3305.104 3305.504 45
115, 50/60 3305.114 3305.514 45
400, 3~, 50
460, 3~, 60 3305.144 3305.544 45
2350
(8000)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
230, 50/60 3328.104 3328.504 46
115, 50/60 3328.114 3328.514 46
400, 3~, 50
460, 3~, 60 3328.144 3328.544 46
2750
(9390)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
230, 50/60 3329.104 3329.504 46
115, 50/60 3329.114 3329.514 46
400, 3~, 50
460, 3~, 60 3329.144 3329.544 46
Delivery times available on request.
Climate Control Overview
13Climate Control
A
4.
Climate Control Overview
4.2 Chillers
Mini
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK
Page
Roof-mount Wall-mount
1120
(3825)
950 x 400 x 310
(37.4 x 15.7 x 12.2)
400, 3~, 50/60/
460, 3~, 60 – 3360.100 52
2800
(9560)
1580 x 400 x 290
(62.2 x 15.7 x 11.4)
400, 3~, 50/60/
460, 3~, 60 – 3360.250 52
4500
(15,370)
1580 x 500 x 340
(62.2 x 19.7 x 13.4)
400, 3~, 50/60/
460, 3~, 60 – 3360.400 52
1070
(3650)
400 x 600 x 430
(15.7 x 23.6 x 16.9) 230, 50/60 3318.600 – 50
3318.610 – 50
1660
(5670)
400 x 600 x 430
(15.7 x 23.6 x 16.9) 230, 50/60 3319.600 – 50
3319.610 – 50
3400
(11,610)
680 x 600 x 625
(26.8 x 23.6 x 24.6)
400, 3~, 50/60/
460, 3~, 60 3320.600 – 51
5400
(18,440)
680 x 600 x 625
(26.8 x 23.6 x 24.6)
400, 3~, 50/60/
460, 3~, 60 3334.600 – 51
Freestanding enclosure
Useful
cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
2100
(7172)
725 x 470 x 540
(28.5 x 18.5 x 21.3) 400, 3~, 50 3336.100 53
2580
(8811)
965 x 485 x 650
(38.0 x 19.1 x 25.6) 400, 3~, 50 3336.200 53
3360
(11,475)
965 x 485 x 650
(38.0 x 19.1 x 25.6) 400, 3~, 50 3336.300 53
5040
(17,213)
1180 x 595 x 800
(46.5 x 23.4 x 31.5) 400, 3~, 50 3336.500 53
6160
(21,038)
1180 x 595 x 800
(46.5 x 23.4 x 31.5) 400, 3~, 50 3336.600 53
7700
(26,297)
1180 x 595 x 800
(46.5 x 23.4 x 31.5) 400, 3~, 50 3336.650 53
12600
(43,030)
1178 x 615 x 1160
(46.4 x 24.2 x 45.7)
400, 3~, 50
460, 3~, 60 3336.700 54
18700
(63,865)
1178 x 615 x 1160
(46.4 x 24.2 x 45.7)
400, 3~, 50
460, 3~, 60 3336.710 54
20100
(68,645)
1178 x 615 x 1160
(46.4 x 24.2 x 45.7)
400, 3~, 50
460, 3~, 60 3336.720 54
23350
(76,330)
1178 x 715 x 1360
(46.4 x 28.1 x 53.5)
400, 3~, 50
460, 3~, 60 3336.730 54
25400
(86,745)
1178 x 715 x 1360
(46.4 x 28.1 x 53.5)
400, 3~, 50
460, 3~, 60 3336.740 54
32250
(110,140)
1178 x 715 x 1360
(46.4 x 28.1 x 53.5)
400, 3~, 50
460, 3~, 60 3336.750 54
Delivery times available on request.
Climate Control Overview
14 Climate Control
A
4.
Climate Control Overview
4.2 Chillers
Freestanding enclosure for oil
Useful
cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
2550
(8709)
965 x 485 x 650
(38.0 x 19.1 x 25.6) 400, 3~, 50 3337.200 55
3400
(11,612)
965 x 485 x 650
(38.0 x 19.1 x 25.6) 400, 3~, 50 3337.300 55
5150
(17,588)
1180 x 595 x 800
(46.5 x 23.4 x 31.5) 400, 3~, 50 3337.500 55
6700
(22,882)
1180 x 595 x 800
(46.5 x 23.4 x 31.5) 400, 3~, 50 3337.600 55
7900
(26,980)
1180 x 595 x 800
(46.5 x 23.4 x 31.5) 400, 3~, 50 3337.650 55
10600
(36,201)
1178 x 615 x 1160
(46.4 x 24.2 x 45.7)
400, 3~, 50
460, 3~, 60 3337.700 56
15150
(51,740)
1178 x 615 x 1160
(46.4 x 24.2 x 45.7)
400, 3~, 50
460, 3~, 60 3337.710 56
17200
(58,741)
1178 x 615 x 1160
(46.4 x 24.2 x 45.7)
400, 3~, 50
460, 3~, 60 3337.720 56
19250
(65,742)
1178 x 715 x 1360
(46.4 x 28.1 x 53.5)
400, 3~, 50
460, 3~, 60 3337.730 56
21600
(73,768)
1178 x 715 x 1360
(46.4 x 28.1 x 53.5)
400, 3~, 50
460, 3~, 60 3337.740 56
26100
(89,136)
1178 x 715 x 1360
(46.4 x 28.1 x 53.5)
400, 3~, 50
460, 3~, 60 3337.750 56
Delivery times available on request.
In the TS8 modular enclosure system
Useful
cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
6000
(20,249)
2000 x 600 x 600
(78.7 x 23.6 x 23.6) 400, 3~, 50 3335.060 57
7500
(25,614)
2000 x 600 x 600
(78.7 x 23.6 x 23.6) 400, 3~, 50 3335.075 57
10000
(34,152)
2000 x 800 x 600
(78.7 x 31.5 x 23.6) 400, 3~, 50 3335.100 58
12000
(40,982)
2000 x 800 x 600
(78.7 x 31.5 x 23.6) 400, 3~, 50 3335.120 58
15000
(51,228)
2000 x 800 x 600
(78.7 x 31.5 x 23.6) 400, 3~, 50 3335.150 58
20000
(68,304)
2000 x 1200 x 600
(78.7 x 47.2 x 23.6) 400, 3~, 50 3335.200 58
25000
(83,379)
2000 x 1200 x 600
(78.7 x 47.2 x 23.6) 400, 3~, 50 3335.250 58
Delivery times available on request.
Climate Control Overview
15Climate Control
A
4.
Climate Control Overview
4.2 Chillers
In an industrial enclosure
Useful
cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
38430
(131,245)
1400 x 815 x 1560
(55.1 x 32.1 x 61.4)
400, 3~, 50
460, 3~, 60 3339.100 59
43480
(148,492)
1400 x 815 x 1560
(55.1 x 32.1 x 61.4)
400, 3~, 50
460, 3~, 60 3339.200 59
20600
(70,349)
1000 x 1800 x 2000
(39.3 x 70.9 x 78.7) 400, 3~, 50 3339.250 59
36800
(125,672)
1000 x 1800 x 2000
(39.3 x 70.9 x 78.7) 400, 3~, 50 3339.280 59
66700
(227,792)
2000 x 1550 x 2500
(78.7 x 61.0 x 98.4) 400, 3~, 50 3339.300 59
75900
(259,212)
2000 x 1550 x 2500
(78.7 x 61.0 x 98.4) 400, 3~, 50 3339.400 59
50000
(170,750)
1550 x 2000 x 3400
(61.1 x 78.7 x 133.9) 400, 3~, 50 3339.450 59
172200
(588,094)
2200 x 1630 x 3400
(86.57 x 64.2 x 133.9) 400, 3~, 50 3339.500 59
Delivery times available on request.
4.2 Immersible Chillers
For oil
Useful
cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No.
SK Page
2700 (9120) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.020 60
3600 (12,295) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.040 60
5200 (17,760) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.060 60
6300 (21,515) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.080 60
9500 (32,445) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.100 61
11800 (40,300) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.120 61
13400 (45,760) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.140 61
15200 (51,910) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.160 61
17100 (58,400) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.180 61
19400 (66,255) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.200 61
23200 (79,230) 1650 x 785 x 1830
(65.0 x 30.9 x 72.04)
400, 3~, 50
460, 3~, 60 3338.220 62
34500 (117,825) 1650 x 785 x 1830
(65.0 x 30.9 x 72.04)
400, 3~, 50
460, 3~, 60 3338.240 62
39100 (133,415) 1650 x 785 x 1830
(65.0 x 30.9 x 72.0)
400, 3~, 50
460, 3~, 60 3338.260 62
49800 (170,075) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.280 62
54400 (185,785) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.300 62
67900 (231,890) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.320 62
81300 (277,655) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.340 62
87200 (297,805) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.360 62
Delivery times available on request.
Climate Control Overview
16 Climate Control
A
4.
Climate Control Overview
4.2 Immersible Chillers
For emulsion
Useful
cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No.
SK Page
2700 (9220) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.500 63
3600 (12,295) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.520 63
5200 (17,760) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.540 63
6300 (21,515) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.560 63
9500 (32,445) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.580 64
11800 (40,300) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.600 64
13400 (45,765) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.620 64
15200 (51,910) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.640 64
17100 (58,400) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.660 64
19400 (66,255) 1650 x 785 x 785
(65.0 x 30.9 x 30.9)
400, 3~, 50
460, 3~, 60 3338.680 64
23200 (79,230) 1650 x 785 x 1830
(65.0 x 30.9 x 72.0)
400, 3~, 50
460, 3~, 60 3338.700 65
34500 (117,825) 1650 x 785 x 1830
(65.0 x 30.9 x 72.0)
400, 3~, 50
460, 3~, 60 3338.720 65
39100 (133,535) 1650 x 785 x 1830
(65.0 x 30.9 x 72.0)
400, 3~, 50
460, 3~, 60 3338.740 65
49800 (170,075) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.760 65
54400 (185,785) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.780 65
67900 (231,890) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.800 65
81300 (277,655) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.820 65
87200 (297,805) 1650 x 1830 x 1830
(65.0 x 72.0 x 72.0)
400, 3~, 50
460, 3~, 60 3338.840 65
Delivery times available on request.
4.3 Air/Water Heat Exchangers
Micro, for wall-mounting
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
300
(1025)
300 x 150 x 85
(11.8 x 5.9 x 3.3)
230, 50/60 3212.230 68
115, 50/60 3212.1151) 68
24 V (DC) 3212.024 68
1) Delivery times available on request.
Climate Control Overview
17Climate Control
A
4.
Climate Control Overview
4.3 Air/Water Heat Exchangers
Wall-mounted
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK Certifications
Page
Wall mount UL CUL DIN GS
600
(2049)
500 x 200 x 100
(19.7 x 7.9 x 3.9) 230, 50/60 3214.100 69
1000
(3415)
520 x 298 x 135
(20.5 x 11.7 x 5.3) 230, 50/60 3217.100 69
1250
(4269)
950 x 200 x 100
(37.4 x 7.9 x 3.9) 230, 50/60 3215.100 70
1540
(5259)
825 x 380 x 105
(32.4 x 15.0 x 4.1) 230, 50/60 3247.000 70
2250
(7384)
950 x 400 x 200
(37.4 x 15.7 x 7.9) 230, 50/60 3218.1041) 71
3000
(10,246)
950 x 400 x 200
(37.4 x 15.7 x 7.9) 230, 50/60 3218.100 71
4500
(15,368)
1400 x 450 x 250
(55.1 x 17.7 x 9.8) 230, 50/60 3216.100 71
7000
(23,905)
450 x 1800 x 300
(17.7 x 70.9 x 11.8) 400, 3~, 50/60 3216.480 71
1) Delivery times available on request.
4.3 TopTherm Air/Water Heat Exchangers
Roof-mounted
Useful
cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz
Part No. SK
Page
With
basic controller
With
comfort controller
1875
(6403)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3209.1041) 3209.5041) 72
115, 50/60 3209.1141) 3209.5141) 72
400, 2~, 50/60 3209.1441) 3209.5441) 72
2500
(8538)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3209.100 3209.500 72
115, 50/60 3209.110 3209.510 72
400, 2~, 50/60 3209.1401) 3209.5401) 72
3000
(10,246)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3210.1041) 3210.5041) 73
115, 50/60 3210.1141) 3210.5141) 73
400, 2~, 50/60 3210.1441) 3210.5441) 73
4000
(13,661)
415 x 597 x 475
(16.3 x 23.5 x 18.7)
230, 50/60 3210.100 3210.500 73
115, 50/60 3210.110 3210.510 73
400, 2~, 50/60 3210.1401) 3210.5401) 73
1) Delivery times available on request.
4.3 Air/Water Heat Exchangers
As a sidewall for TS8 modular enclosures
Useful
cooling
capacity
W (BTU)
For modular
enclosure
dimensions
H x D
mm (inches)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
700
(2391)
1800 x 600
(70.9 x 23.6)
1800 x 600 x 95
(70.9 x 23.6 x 3.7) 230, 50/60 3316.180 74
700
(2391)
2000 x 600
(78.7 x 23.6)
2000 x 600 x 95
(78.7 x 23.6 x 3.7) 230, 50/60 3316.200 74
Climate Control Overview
18 Climate Control
A
4.
Climate Control Overview
4.3 TopTherm Air/Air Heat Exchangers
Wall-mounting
Specific thermal
capacity
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Certifications
Page
UL CUL DIN GS
12.0 W/C 200 x 400 x 146
(7.8 x 15.7 x 4.8) 230, 50/60 3125.800 77
17.5 W/C 550 x 280 x 150
(21.7 x 11.0 x 5.9) 230, 50/60 3126.100 75
30.0 W/C 950 x 400 x 205
(37.4 x 15.7 x 8.1) 230, 50/60 3127.100 75
45.0 W/C 950 x 400 x 225
(37.4 x 15.7 x 8.9) 230, 50/60 3128.100 75
60.0 W/C 950 x 400 x 225
(37.4 x 15.7 x 8.9) 230, 50/60 3129.100 75
62.0 W/C 400 x 1360 x 110
(15.7 x 53.0 x 4.3) 230, 50/60 3129.800 77
90.0 W/C 1580 x 400 x 215
(62.2 x 15.7 x 8.5) 230, 50/60 3130.100 76
4.4 Filter Fan Unit
Air displacement,
unimpeded air flow
Voltage
V, Hz Part No. SK Certifications Page
UL CUL DIN GS CSA
20/25 m3/h
(12/15 cfm)
230, 50/60 3321.107 79
115, 50/60 3321.117 79
20 m3/h
(12 cfm)
24 (DC) 3321.027 79
48 (DC) 3321.0471) 79
55/66 m3/h
(32/39 cfm)
230, 50/60 3322.107 79
115, 50/60 3322.117 79
55 m3/h
(32 cfm)
24 (DC) 3322.027 79
48 (DC) 3322.0471) 79
105/120 m3/h
(62/71 cfm)
230, 50/60 3323.107 80
115, 50/60 3323.117 80
105 m3/h
(62 cfm)
24 (DC) 3323.027 80
48 (DC) 3323.0471) 80
160/180 m3/h
(94/106 cfm)
230, 50/60 3324.107 80
115, 50/60 3324.117 80
180 m3/h
(106 cfm)
24 (DC) 3324.027 80
48 (DC) 3324.0471) 80
230/265 m3/h
(135/156 cfm)
230, 50/60 3325.107 81
115, 50/60 3325.117 81
230 m3/h
(135 cfm)
24 (DC) 3325.027 81
48 (DC) 3325.0471) 81
550/600 m3/h
(324/353 cfm)
230, 50/60 3326.107 82
115, 50/60 3326.117 82
700/720 m3/h
(412/424 cfm)
230, 50/60 3327.107 82
115, 50/60 3327.117 82
400/460, 3~, 50/60 3327.147 82
1160 m3/h
(680 cfm)
230, 50/60 9964.986
115, 50/60 9964.980
1) Delivery times available on request.
Climate Control Overview
19Climate Control
A
4.
Climate Control Overview
4.4 Filter Fan Unit – EMC
Air displacement,
unimpeded air flow
Voltage
V, Hz Part No. SK Certifications Page
UL CUL DIN GS CSA
20/25 m3/h
(12/15 cfm)
230, 50/60 3321.607 83
115, 50/60 3321.6171) 83
55/66 m3/h
(32/39 cfm)
230, 50/60 3322.607 83
115, 50/60 3322.6171) 83
105/120 m3/h
(62/71 cfm)
230, 50/60 3323.607 83
115, 50/60 3323.6171) 83
160/180 m3/h
(94/106 cfm)
230, 50/60 3324.607 84
115, 50/60 3324.6171) 84
230/265 m3/h
(135/156 cfm)
230, 50/60 3325.607 84
115, 50/60 3325.617 84
550/600 m3/h
(324/353 cfm)
230, 50/60 3326.607 84
115, 50/60 3326.6171) 84
700/720 m3/h
(412/424 cfm)
230, 50/60 3327.607 84
115, 50/60 3327.6171) 84
1) Delivery times available on request.
4.5 Rack-Mounted Air Conditioners
Useful cooling
capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
1000
(3415)
265.9 x 445 x 542
(10.5 x 17.5 x 21.3)
115, 50/60 3278.1341) 87
230, 50/60 3292.134 87
1) Delivery times available on request.
4.5 Rack-Mounted Fan
Air
displacement,
unimpeded
air flow
No. of
fans
Distance
between
axes
mm (inches)
Voltage
V, Hz Part No.
SK
Certifications
Page
UL CUL DIN GS VDE
250 m3/h
(147 cfm) 3 85 (3.3) 36 (DC) – 72 (DC) 9769.0021) 88
320 m3/h
(188 cfm)
2 85 (3.3) 24 (DC) 3340.0241) 88
2 85 (3.3) 115 (AC), 50/60 3340.1151) 88
2 85 (3.3) 230 (AC), 50/60 3340.230 88
480 m3/h
(283 cfm)
3 85 (3.3) 24 (DC) 3341.0241) 88
3 105 (4.1) 24 (DC) 3342.024 88
3 85 (3.3) 115 (AC), 50/60 3341.115 88
3 105 (4.1) 115 (AC), 50/60 3342.1151) 88
3 85 (3.3) 230 (AC), 50/60 3341.230 88
3 105 (4.1) 230 (AC), 50/60 3342.230 88
3 105 (4.1) 24 (DC)
115 – 230 (AC), 50/60 3342.500 88
1) Delivery times available on request.
Climate Control Overview
20 Climate Control
A
4.
Climate Control Overview
4.5 Vario Rack-Mounted Fan
Air
displacement,
unimpeded
air flow
No. of
fans
Distance
between axes
mm (inches)
Voltage
V, Hz Part No.
SK
Certifications
Page
UL CUL DIN GS VDE
320 m3/h
(188 cfm)
2 85 (3.3) 24 (DC) 3350.0241) 88
2 85 (3.3) 115 (AC), 50/60 3350.1151) 88
2 85 (3.3) 230 (AC), 50/60 3350.230 88
480 m3/h
(283 cfm)
3 85 (3.3) 24 (DC) 3351.0241) 88
3 105 (4.1) 24 (DC) 3352.0241) 88
3 85 (3.3) 115 (AC), 50/60 3351.1151) 88
3 105 (4.1) 115 (AC), 50/60 3352.1151) 88
3 85 (3.3) 230 (AC), 50/60 3351.230 88
3 105 (4.1) 230 (AC), 50/60 3352.230 88
3 105 (4.1)
24 (DC)
115 – 230 (AC),
50/60 3352.5001) 88
1) Delivery times available on request.
4.5 Centrifugal Fan
Air
displacement,
unimpeded
air flow
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
320 m3/h
(188 cfm)
87 x 482 x 158
(3.4 x 19.0 x 6.2)
115, 50/60 3145.000 89
230, 50/60 3144.000 89
4.5 Roof-Mounted Fan and Vent Attachment
For TS8 modular enclosures
Air displacement,
unimpeded air flow
Voltage
V, Hz
Required mounting cutout
W x D
mm (inches) Part No. SK Page
400 m3/h
(235 cfm)
115, 50/60 475 x 260 (18.7 x 10.2) 3149.410 90
230, 50/60 475 x 260 (18.7 x 10.2) 3149.420 90
400, 3~, 50/60
460, 3~, 60 475 x 260 (18.7 x 10.2) 3149.440 90
800 m3/h
(471 cfm)
115, 50/60 475 x 260 (18.7 x 10.2) 3149.810 90
230, 50/60 475 x 260 (18.7 x 10.2) 3149.820 90
400, 3~, 50/60
460, 3~, 60 475 x 260 (18.7 x 10.2) 3149.840 90
Without motor 490 x 390 (19.3 x 15.4) 8801.380 90
4.5 Roof-Mounted Fans
Air displacement,
unimpeded air flow
Voltage
V, Hz
Required mounting cutout
W x D mm
(inches) Part No. SK Page
360 m3/h (212 cfm) 230, 50/60 345 x 265 (13.6 x 10.4) 3149.007 90
115, 50/60 3169.007 90
Without fan motor 345 x 265 (13.6 x 10.4) 3148.007 90
625 m3/h (360 cfm) 230, 50/60 345 x 265 (13.6 x 10.4) 9966.815 + 9967.776
625 m3/h (360 cfm) 115, 50/60 345 x 265 (13.6 x 10.4) 9966.814 + 9967.775 EMC
Climate Control Overview
21Climate Control
A
4.
Climate Control Overview
4.5 Roof-Mounted Fans
For TS/FR(i) for the office sector
Air
displacement,
unimpeded
air flow
Voltage
V, Hz
Version Dimensions
H x W x D
mm (inches)
Part No.
SK
Certifications
Page
With
roof
plate
Without
roof
plate
UL CUL DIN GS CSA
1,500 m3/h
(883 cfm)
115, 50/60 240 x 800 x 800
(9.4 x 31.5 x 31.5)
3164.610 91
230, 50/60 3164.620 91
1,500 m3/h
(883 cfm)
115, 50/60 240 x 800 x 900
(9.4 x 31.5 x 35.4)
3164.810 91
230, 50/60 3164.820 91
1,500 m3/h
(883 cfm)
115, 50/60 227 x 511 x 511
(8.9 x 20.1 x 20.1)
3164.115 91
230, 50/60 3164.230 91
4.6 Enclosure Heaters
Continuous
thermal output
for
Tu = 20°C (68°F)
W
Voltage
V, Hz Part No. SK
Certifications
Page
UL CUL DIN GS VDE
10 110 – 240 (AC/DC) 3105.000 98
20 110 – 240 (AC/DC) 3106.000 98
30 110 – 240 (AC/DC) 3115.000 98
50 110 – 240 (AC/DC) 3116.000 98
130 110 – 240 (AC/DC) 3107.000 + 3108.000 98
300 230, 50/60 3102.000 (incl. fan) 98
300 115, 50/60 3102.110 98
4.6 Enclosure Heaters
For CS outdoor enclosures
Continuous
thermal output
Tu = 20°C (68°F)
W
Voltage
V, Hz
Installation Dimensions
H x W x D
mm (inches)
Part No.
CS
Certifications
Page
In the
enclosure
19˝
rails UL CUL DIN GS VDE
1000 230, 50/60 – 82 x 325 x 220
(3.2 x 12.8 x 8.7) 9769.015 99
600 230, 50/60 – 87.2 x 482.6 x 236
(3.4 x 19.0 x 9.3) 9769.023 99
4.8 Liquid Cooling Package
Cooling capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No.
SK Page
Enclosure + 3 modules
4000 (13,661) 2000 x 300 x 1000 (78.7 x 11.8 x 39.4) 230, 50/60 3301.230 115
4000 (13,661) 2000 x 300 x 1000 (78.7 x 11.8 x 39.4) 115, 50/60 3301.210 115
Cooling module, single
4000 (13,661) 250 x 550 x 950 (9.8 x 21.7 x 37.4) 230, 50/60 3301.250 115
4.8 Rack-Mounted Chiller
Specific
thermal capacity
W (BTU)
Dimensions
H x W x D
mm (inches)
Voltage
V, Hz Part No. SK Page
1000 (3415) 442 x 175 x 751
(17.4 x 6.9 x 29.6) 230, 50/60 3301.260 116
Delivery times available on request.
22 Climate Control
Air Conditioners
Features
B
4.1
Air Conditioners
Rittal Climate Control offers comprehensive process protec-
tion for virtually any application. This includes the cooling of
sensitive electronics in enclosures and cases for industrial
process control, and server and network technology,
regardless of ambient conditions. But Rittal’s climate control
systems are not isolated solutions, with Rittal, everything is
interconnected. Perfectly linked and controlled cooling tech-
nology combined with eco-friendly, energy-efficient equip-
ment, create the perfect environment for your equipment.
Selection criteria
Intelligent control
Integrated cooling technology
The combination of enclosure
and cooling components pro-
vides excellent cooling, cost
savings and reduced assembly
time.
Roof-mounted air conditioners
Requirement oriented routing of
cooling air in the internal circuit
is possible with up to four cold
air outlet openings and the op-
tional use of ducts. In the exter-
nal circuit, the heated air is ex-
pelled to the rear, left, right, and
optionally upwards. This allows
enclosures to be bayed together
or to be installed close to the
wall.
Wall-mounted air conditioners
Depending on the space and
design requirements, internal
mounting, partial internal mount-
ing and external mounting are all
possible. Effective cold air dissi-
pation throughout the enclosure
is achieved by large distances
between the air intake and out-
let openings.
Rittal offers basic and comfort
control versions for operational
reliability. Both versions offer a
comprehensive range of func-
tions. Essential control electron-
ics are well protected and
cooled in the inner circuit.
Both versions have the following
properties:
●Three voltage options:
115 V, 230 V, 400/460 V 3~
●Integrated start-up delay and
door limit switch function
●Icing protection function
●Monitoring of all motors
●Phase monitoring for three-
phase units
Basic controller:
●Visualization of the operating
status by a LED display
●Switching hysteresis: 5 K
●Floating fault signal contact in
case of over temperature
●Set-point adjustable from the
outside by a potentiometer
(setting range 20° – 55°C
(68° – 131°F))
Comfort controller:
●Switching hysteresis: 2 – 10 K
preset to 5 K
●System alarm, individually
configurable for 2 floating fault
signal contacts
●Visualization of the current
enclosure internal tempera-
ture and all system messages
on the display
●Storage of all system states in
the log file
●Optional extension card for
integration into superordinate
remote monitoring systems
(CMC)
23Climate Control
Air Conditioners
Features
B
4.1
Air Conditioners
Flexible performance
Only 3 mounting cutouts for
6 different output categories in
28 design versions.
Targeted air routing in the
enclosure
The internal air circulation is tar
-
geted and effective: The heated air
is extracted centrally. Air exhaust
occurs in the four corners, based
on your specific requirements.
Flexible condensate
management
All roof-mounted air condition-
ers with comfort controller are
equipped with a condensate
warning feature. A condensate
pump and condensate evapora-
tor may be integrated.
Integrated cooling technology
Infinite possibilities
The TS8 modular enclosure sys-
tem platform offers full compati-
bility in terms of baying tech-
niques, lock systems and interior
installation.
Quick exchange of the door
and sidewall
The symmetrical design allows
the climate control door to be
easily changed.
Exchangeable in a flash
With all integrated cooling tech-
nology models, the cooling mod-
ule can be quickly exchanged in
just a few steps.
Roof-mounted air conditioners
Wall-mounted air conditioners
Wall-mounted air conditioners
– Practical and stylish
The mounting cutout is selected
depending on the mounting
type: external, internal or partial
internal mount. This makes opti-
mum use of the available space.
Effective air routing inside the
enclosure
The large distance between the
air intake and outlet in the inter-
nal circuit makes wall-mounted
air conditioners particularly
effective. This ensures optimum
air dissipation inside the enclo-
sure, and air short-circuits are
avoided.
Developed for easy servicing,
inside and out
The assemblies, their arrange-
ment and the divided internal
case construction make all types
of maintenance and servicing
work much easier.
Benefits:
●Useful cooling capacity from
225 to 4000 W
(768 to 13,661 BTU)
●Extensive control and moni-
toring features, even with the
basic version
●Three-phase air conditioners
support multiple voltages as
standard
●Uniform, output-related,
cross-system mounting
cutouts, to match TopTherm
air/air heat exchangers
●Targeted, individual air
routing
●No assembly work and low
investment costs, due to the
complete solution consisting
of an enclosure and inte-
grated air conditioner1)
●May be integrated directly
into TS8 bayed enclosure
suites1)
Important:
●Use a base/plinth of at least
100 mm (3.9˝) high to ensure
unhindered air entry1)
●Avoid overloading the roof-
plate by using stays (see
TS8 system accessories)
●Air intake and outlet open-
ings in the internal and exter-
nal circuit must not be
blocked.
1) Only for integrated cooling
technology.
Climate Controlled Enclosures
Enclosures, single-door, useful cooling capacity 1250/1510 W (4270/5150 BTU)
24 Climate Control
B
4.1
Climate Controlled Enclosures
T1
H
B
T2
T3
Configuration:
Enclosure frame with rear-wall,
roof and climate control door,
including TS8 hinges, door
opening angle approximately
110°, painted, including pre-
assembled cooling module, right
door hinge, may be changed to
opposite side, 4 eyebolts, pre-
fitted, mounting panel, three-part
gland panels, depth stay as
shipping brace.
Also required:
For correct functioning of the
external circuit:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Microcontroller control with:
●Digital temperature indicator,
●Floating contact for collective
fault signal,
●Connection for door operated
switch for start-up delay,
●Automatic condensate
evaporation.
Certifications,
see page 7.
Detailed drawing,
see page 119.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK1) 8687.100 8607.100 8687.840 8607.840 8887.150 8807.100 8887.140 8807.140
Voltage V, Hz 230, 50/60 400, 2~, 50/60 230, 50/60 400, 2~, 50/60
Dimensions in mm (inches)
H
B
T1
T2
1800 (70.9)
600 (23.6)
600 (23.6)
100 (3.9)
2000 (78.7)
600 (23.6)
600 (23.6)
100 (3.9)
1800 (70.9)
600 (23.6)
600 (23.6)
100 (3.9)
2000 (78.7)
600 (23.6)
600 (23.6)
100 (3.9)
1800 (70.9)
800 (31.5)
600 (23.6)
100 (3.9)
2000 (78.7)
800 (31.5)
600 (23.6)
100 (3.9)
1800 (70.9)
800 (31.5)
600 (23.6)
100 (3.9)
2000 (78.7)
800 (31.5)
600 (23.6)
100 (3.9)
Maximum installation depth up to
mounting panel in mm (inches) T3 478 (18.8)
Suitable for baying with TS8 modular
enclosures in mm (inches) T 600 (23.6)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1100/1250 (3756/4269)
820/1000 (2800/3412) 1500/1510 (5123/5157)
1065/1240 (3637/4235)
Maximum rated current 3.2 A/3.8 A 1.9 A/2.2 A 4.0 A/4.5 A 2.3 A/2.6 A
Starting current 11.0 A/12.0 A 6.3 A/6.9 A 9.0 A/10.0 A 5.2 A/5.7 A
Pre-fuse T 10.0 A/10.0 A 6.0 A/6.0 A 10.0 A/10.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
525/630 W
605/725 W
540/650 W
625/750 W
650/750 W
750/850 W
670/780 W
780/880 W
Refrigeration coefficient
ε = QK/Pel L 35 L 35 2.1 2.3
Refrigerant R134a, 675 g (24 oz) R134a, 700 g (25 oz)
Maximum allowable operating pressure 23 bar (334 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 155 (341.7) 163 (359.3) 158 (348.3) 166 (366.0) 182 (401.2) 192 (423.3) 185 (407.9) 195 (429.9)
Color RAL 7035 (light gray)2)
Air displacement of fans External circuit 580 m3/h (341.4 cfm) 600 m3/h (353.1 cfm)
Internal circuit 420 m3/h (247.2 cfm) 480 m3/h (282.5 cfm)
Temperature control Internal thermostat (factory setting +35°C (95°F))
Also required PU
Base/plinth components
front/rear, 100 mm (3.9˝) 1 set 8601.600 8601.800
Base/plinth trim, side,
100 mm (3.9˝) 1 set 8601.060
Sidewalls 2 8186.235 8106.235 8186.235 8106.235 8186.235 8106.235 8186.235 8106.235
1) Delivery times available on request.
2) RAL 7032 (pebble gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 3 295 093
B = Width
T = Depth
Enclosures, two-door, useful cooling capacity 2000/2550 W (6865/8708 BTU)
Climate Controlled Enclosures
25Climate Control
B
4.1
Climate Controlled Enclosures
B
T1
H
T2
T3
Configuration:
Enclosure frame with rear-wall,
roof and climate control door,
including TS8 hinges, door
opening angle approximately
110°, lockable door with stand-
ard hinges, painted, including
pre-assembled cooling module,
4 eyebolts, pre-fitted, mounting
panel, three-part gland panels,
depth stays as shipping braces.
Also required:
For correct functioning of the
external circuit:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Microcontroller control with:
●Digital temperature indicator,
●Floating contact for collective
fault signal,
●Connection for door operated
switch for start-up delay,
●Automatic condensate
evaporation.
Certifications,
see page 7.
Detailed drawing,
see page 119.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK1) 8287.170 8807.180 8207.170 8207.180 8807.260 8807.250
Device position right left right left left
Voltage V, Hz 230, 50/60 400, 3~, 50/60
Dimensions in mm (inches)
H
B
T1
T2
1800 (70.9)
1200 (47.2)
600 (23.6)
100 (3.9)
1800 (70.9)
1200 (47.2)
600 (23.6)
100 (3.9)
2000 (78.7)
1200 (47.2)
600 (23.6)
100 (3.9)
1800 (70.9)
1200 (47.2)
600 (23.6)
100 (3.9)
2000 (78.7)
1200 (47.2)
600 (23.6)
100 (3.9)
Maximum installation depth to mounting panel
in mm (inches) T3 445 (17.5) 445 (17.5) 445 (17.5) 415 (16.3) 415 (16.3)
Suitable for baying with TS8 modular enclosures
in mm (inches) T 600 (23.6)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 2000/2010 (6830/6865)
1420/1650 (4850/5635) 2500/2550 (8538/8708)
1650/1750 (5635/5977)
Maximum rated current 5.8 A/6.3 A 3.0 A/3.2 A
Starting current 26.0 A/29.0 A 14.0 A/16.0 A
Pre-fuse T 16.0 A/16.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
960/1070 W
1030/1180 W
1330/1640 W
1580/2000 W
Refrigeration coefficient ε = QK/Pel L 35 L 35 2.1 1.9
Refrigerant R134a, 925 g (32.6 oz) R134a, 975 g (34.4 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Rating
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 231 (509.2) 246 (542.3) 231 (509.2) 245 (540.1)
Color RAL 7035 (light gray)2)
Air displacement of fans External circuit 630 m3/h (371 cfm) 700 m3/h (412 cfm)
Internal circuit 520 m3/h (306 cfm) 620 m3/h (365 cfm)
Temperature control Internal thermostat (factory setting +35°C (95°F))
Also required PU
Base/plinth components front/rear, 100 mm (3.9˝) 1 set 8601.200
Base/plinth trim, side, 100 mm (3.9˝) 1 set 8601.060
Sidewalls 1 set 8186.235 8106.235 8186.235 8106.235
1) Delivery times available on request.
2) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 3 295 093
B = Width
T = Depth
Climate Control Doors
For 600 mm (23.6˝) wide TS8 modular enclosures, useful cooling capacity 1250/1680 W (4269/5738 BTU)
26 Climate Control
B
4.1
Climate Control Doors
modular
Part No. SK with thermostat 3306.8801) 3306.8001) 3306.8841) 3306.8401) 3307.8801) 3307.8001) 3307.8901) 3307.840
Part No. SK with microcontroller 3306.5801) 3306.5001) 3306.5901) 3306.5401) 3307.5801) 3307.5001) 3307.5901) 3307.5401)
Voltage V, Hz 230, 50/60 400, 2~, 50/60 230, 50/60 400, 2~, 50/60
Dimensions in mm (inches)
H
B1
B2
T1
T2
1777 (70)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1977 (77.9)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1777 (70)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1977 (77.9)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1777 (70)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1777 (70.0)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
Dimensions to fit
TS8 modular enclosures
in mm (inches)
H
B
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1100/1250 (3756/4269)
820/1000 (2800/3415) 1500/1680 (5123/5738)
1110/1120 (3791/3825)
Maximum rated current 3.2 A/3.8 A 1.9 A/2.2 A 4.2 A/4.8 A 2.4 A/2.8 A
Starting current 11.0 A/12.0 A 6.3 A/6.9 A 22.0 A/24.0 A 12.7 A/13.8 A
Pre-fuse T 10.0 A/10.0 A 6.0 A/6.0 A 16.0 A/16.0 A 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
525 W/630 W
605 W/725 W
540 W/650 W
625 W/750 W
560 W/710 W
670 W/840 W
570 W/725 W
680 W/860 W
Refrigeration coefficient
ε = QK/Pel L 35 L 35 2.1
Refrigerant R134a, 675 g (23.8 oz) R134a, 800 g (28.2 oz)
Maximum allowable operating pressure 23 bar (334 psi) 26 bar (377 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 58 (127.9) 60 (132.2) 61 (134.5) 63 (138.9) 72 (158.7) 75 (165.3)
Color RAL 7035 (light gray)2)
Air displacement
of fans
External circuit 580 m3/h (341 cfm) 600 m3/h (353 cfm)
Internal circuit 420 m3/h (247 cfm) 480 m3/h (283 cfm)
Temperature control Internal thermostat or microcontroller control (factory setting +35°C (95°F))
Accessories PU Page
Metal filters 1 3284.200 112
Door-operated switch 1 4127.000 –
Temperature indicator 1 3114.100 103
Air diverter 1 3213.300 – 102
1) Delivery times available on request.
2) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
B2
T1
B1
T2
H
Configuration:
Climate control door unit with
pre-fitted cooling module,
including TS8 hinges, door
opening angle approximately
110°.
Note:
Climate control doors for two-
door TS8 modular enclosures
see pages 29/30.
Also required:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Automatic condensate
evaporation.
Certifications,
see pages 7/8.
Detailed drawing,
see page 120.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent
no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 0 299 406
Japanese patent no. 3 295 093
B = Width
T = Depth
For 800 mm (31.5˝) wide TS8 modular enclosures, useful cooling capacity 1510 W (5150 BTU)
Climate Control Doors
27Climate Control
B
4.1
Climate Control Doors
B2
T1
B1
T2
H
Configuration:
Climate control door unit with
pre-fitted cooling module, in-
cluding TS8 hinges, door open-
ing angle approximately 110°.
Also required:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Automatic condensate
evaporation.
Certifications,
see pages 7/8.
Detailed drawing,
see page 120.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. SK with thermostat 3308.8801) 3308.8001) 3308.8841) 3308.8401)
Part No. SK with microcontroller 3308.5801) 3308.500 3308.5901) 3308.540
Voltage V, Hz 230, 50/60 400, 2~, 50/60
Dimensions in mm (inches)
H
B1
B2
T1
T2
1777 (70.0)
792 (31.2)
661 (26.2)
157 (6.2)
57 (2.2)
1977 (77.9)
792 (31.2)
661 (26.2)
157 (6.2)
57 (2.2)
1777 (70.0)
792 (31.2)
661 (26.2)
157 (6.2)
57 (2.2)
1977 (77.9)
792 (31.2)
661 (26.2)
157 (6.2)
57 (2.2)
Dimensions to fit
TS8 modular enclosures in mm (inches)
H
B
1800 (70.9)
800 (31.5)
2000 (78.7)
800 (31.5)
1800 (70.9)
800 (31.5)
2000 (78.7)
800 (31.5)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1500/1510(5123/5157)
1065/1240 (3637/4235)
Maximum rated current 4.0 A/4.5 A 2.3 A/2.6 A
Starting current 9.0 A/10.0 A 5.2 A/5.7 A
Pre-fuse T 10.0 A/10.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
650 W/750 W
750 W/850 W
670 W/780 W
780 W/880 W
Refrigeration coefficient ε = QK/Pel L 35 L 35 2.3
Refrigerant R134a, 700 g (24.7 oz)
Maximum allowable operating pressure 23 bar (334 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 65 (143.3) 67 (147.7) 68 (149.9) 70 (154.3)
Color RAL 7035 (light gray)2)
Air displacement of fans External circuit 600 m3/h (353 cfm)
Internal circuit 480 m3/h (283 cfm)
Temperature control Internal thermostat or microcontroller control (factory setting +35°C (95°F))
Accessories PU Page
Metal filters 1 3288.200 112
Door-operated switch 1 4127.000 –
Temperature indicator 1 3114.100 103
Air diverter 1 Available on request. –
1) Delivery times available on request.
2) RAL 7032 (pebble gray) on request.
Special voltages available on request.We reserve the right to make technical modifications.
.
.
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 0 299 406
Japanese patent no. 3 295 093
B = Width
T = Depth
Climate Control Doors
For 600 mm (23.6˝) wide TS8 modular enclosures, useful cooling capacity 2010/2550 W (6865/8709 BTU)
28 Climate Control
B
4.1
Climate Control Doors
B2
T1
B1
T2
H
Configuration:
Climate control door unit with
pre-fitted cooling module, in-
cluding TS8 hinges, door open-
ing angle approximately 110°.
Note:
Climate control doors for two-
door TS8 enclosures,
see pages 29/30.
Also required:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Automatic condensate
evaporation.
Certifications,
see pages 7/8.
Detailed drawing,
see page 120.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. SK with thermostat 3309.8801) 3309.800 3309.8841) 3309.8401) 3310.8801) 3310.800
Part No. SK with microcontroller 3309.5801) 3309.500 3309.5901) 3309.540 3310.5801) 3310.5001)
Voltage V, Hz 230, 50/60 400, 2~, 50/60 400, 3~, 50/60
Dimensions in mm (inches)
H
B1
B2
T1
T2
1777 (70.0)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1777 (70.0)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1777 (70.0)
592 (23.3)
461 (18.1)
220 (8.7)
120 (4.7)
1977 (77.9)
592 (23.3)
461 (18.1)
220 (8.7)
120 (4.7)
Dimensions to fit
TS8 modular enclosures in mm (inches)
H
T
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 2000/2010 (6830/6865)
1420/1650 (4850/5635) 2500/2550 (8538/8709)
1650/1750 (4850/19,245)
Maximum rated current 5.8 A/6.3 A 3.4 A/3.6 A 3.0 A/3.2 A
Starting current 26.0 A/29.0 A 15.0 A/16.5 A 14.0 A/16.0 A
Pre-fuse T 16.0 A/16.0 A 10.0 A/10.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
960 W/1070 W
1030 W/1180 W
985 W/1100 W
1055 W/1210 W
1330 W/1640 W
1580 W/2000 W
Cooling coefficient ε = QK/Pel L 35 L 35 2.1 1.9
Refrigerant R134a, 925 g (32.6 oz) R134a, 975 g (34.4 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 72 (158.7) 74 (163.1) 75 (165.3) 77 (169.8) 74 kg (163.1) 76 (167.6)
Color RAL 7035 (light gray)2)
Air displacement of fans External circuit 630 m3/h (371 cfm) 700 m3/h (412 cfm)
Internal circuit 520 m3/h (306 cfm) 620 m3/h (365 cfm)
Temperature control Internal thermostat or microcontroller control (factory setting +35°C (95°F))
Accessories PU Page
Metal filters 1 3284.200 112
Door-operated switch 1 4127.000 –
Temperature indicator 1 3114.100 103
1) Delivery times available on request.
2) RAL 7032 (pebble gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 0 299 406
Japanese patent no. 3 295 093
B = Width
T = Depth
For 1200 mm (47.2˝) wide TS8 modular enclosure, useful cooling capacity 1250/1680 W (4269/5738 BTU)
Climate Control Doors
29Climate Control
B
4.1
Climate Control Doors
B2
T1
B1
T2
H
Configuration:
Climate control door unit with
pre-fitted cooling module, in-
cluding TS8 hinges, door open-
ing angle approximately 110°.
Note:
With the device positioned on
the right, one pack consists of a
climate control door for installing
in the right side of the enclosure,
and a lockable door for the left.
With the device positioned on
the left, one pack consists of a
climate control door for installing
on the left side of the enclosure.
The existing lockable door on
the right may be used.
Climate control doors for single-
door TS8 modular enclosures,
see pages 26 – 30.
Also required:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Automatic condensate
evaporation.
Certifications,
see page 8.
Detailed drawing,
see page 120.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK
with thermostat1)
left 3306.270 3306.230 3306.470 3306.430 3307.270 3307.230 3307.470 3307.430
right 3306.250 3306.210 3306.450 3306.410 3307.250 3307.210 3307.450 3307.410
Part No. SK
with microcontroller1)
left 3306.570 3306.530 3306.670 3306.630 3307.570 3307.530 3307.670 3307.630
right 3306.550 3306.510 3306.650 3306.610 3307.550 3307.510 3307.650 3307.610
Voltage V, Hz 230, 50/60 400, 2~, 50/60 230, 50/60 400, 2~, 50/60
Dimensions
in mm (inches)
H
B1
B2
T1
T2
1777 (70)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1977 (77.9)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1777 (70)
592 (23.3)
461 (18.1
157 (6.2)
57 (2.2)
1977 (77.9)
592 (23.3)
461 (18.1)
157 (6.2)
57 (2.2)
1777 (70)
592 (23.3)
461 (18.1
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1777 (70.0)
592 (23.3)
461 (18.1
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
Dimensions to fit
TS8 modular enclosures
in mm (inches)
H
B
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1100/1250 (3756/4269)
820/1000 (2800/3412) 1500/1680 (5123/5738)
1110 W/1120 W (3791/3825)
Maximum rated current 3.2 A/3.8 A 1.9 A/2.2 A 4.2 A/4.8 A 2.4 A/2.8 A
Starting current 11.0 A/12.0 A 6.3 A/6.9 A 22.0 A/24.0 A 12.7 A/13.8 A
Pre-fuse T 10.0 A/10.0 A 6.0 A/6.0 A 16.0 A/16.0 A 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
525 W/630 W
605 W/725 W
540 W/650 W
625 W/750 W
560 W/710 W
670 W/840 W
570 W/725 W
680 W/860 W
Cooling coefficient ε = QK/Pel L 35 L 35 2.1
Refrigerant R134a, 675 g (23.8 oz) R134a, 800 g (28.2 oz)
Maximum allowable operating pressure 23 bar (334 psi) 26 bar (377 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 58 (127.9) 60 (132.2) 61 (134.5) 63 kg (138.9) 72 (158.7) 75 (165.3)
Color RAL 7035 (light gray)2)
Air displacement of fans External circuit 580 m3/h (341 cfm) 600 m3/h (353 cfm)
Internal circuit 420 m3/h (247 cfm) 480 m3/h (283 cfm)
Temperature control Internal thermostat or microcontroller control (factory setting +35°C (95°F))
Accessories PU Page
Metal filters 1 3284.200 112
Door-operated switch 1 4127.000 –
Temperature indicator 1 3114.100 103
Air diverter 1 3213.300 – 102
1) Delivery times on request. 2) RAL 7032 (pebble gray) on request. Special voltages available on request. Technical modifications reserved.
.
.
Accessories Page 100
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 0 299 406
Japanese patent no. 3 295 093
B = Width
T = Depth
Climate Control Doors
For 1200 mm (47.2˝) wide TS8 modular enclosures, useful cooling capacity 2010/2550 W (6865/8708 BTU)
30 Climate Control
B
4.1
Climate Control Doors
Part No. SK with thermostat1) left 3309.210 3309.140 3309.410 3309.440 3310.150 3310.130
Part No. right 3309.170 3309.120 3309.470 3309.420 3310.250 3310.230
Part No. SK with microcontroller1) left 3309.510 3309.530 3309.610 3309.640 3310.550 3310.530
Part No. right 3309.570 3309.520 3309.670 3309.620 3310.650 3310.630
Voltage V, Hz 230, 50/60 400, 2~, 50/60 400, 3~, 50/60
Dimensions in mm (inches)
H
B1
B2
T1
T2
1777 (70)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1777 (70)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1977 (77.9)
592 (23.3)
461 (18.1)
190 (7.5)
90 (3.5)
1777 (70.0)
592 (23.3)
461 (18.1)
220 (8.7)
120 (4.7)
1977 (77.9)
592 (23.3)
461 (18.1)
220 (8.7)
120 (4.7)
Dimensions to fit
TS8 modular enclosures in mm (inches)
H
B
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
1800 (70.9)
1200 (47.2)
2000 (78.7)
1200 (47.2)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 2000/2010 (6830/6865)
1420/1650 (4850/5635) 2500/2550 (8538/8708)
1650/1750 (5635/5977)
Maximum rated current 5.8 A/6.3 A 3.4 A/3.6 A 3.0 A/3.2 A
Starting current 26.0 A/29.0 A 15.0 A/16.5 A 14.0 A/16.0 A
Pre-fuse T 16.0 A/16.0 A 10.0 A/10.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
960 W/1070 W
1030 W/1180 W
985 W/1100 W
1055 W/1210 W
1330 W/1640 W
1580 W/2000 W
Cooling coefficient ε = QK/Pel L 35 L 35 2.1 1.9
Refrigerant R134a, 925 g (32.6 oz) R134a, 975 g (34.4 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 72 (158.7) 74 (163.1) 75 (165.3) 77 (169.8) 74 (163.1) 76 (167.6)
Color RAL 7035 (light gray)2)
Air displacement of fans External circuit 630 m3/h (371 cfm) 700 m3/h (412 cfm)
Internal circuit 520 m3/h (306 cfm) 620 m3/h (365 cfm)
Temperature control Internal thermostat or microcontroller control (factory setting +35°C (95°F))
Accessories PU Page
Metal filters 1 3284.200 112
Door-operated switch 1 4127.000 –
Temperature indicator 1 3114.100 103
1) Delivery times on request.
2) RAL 7032 (pebble gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
B2
T1
B1
T2
H
Configuration:
Climate control door unit with
pre-fitted cooling module, in-
cluding TS8 hinges, door open-
ing angle approximately 110°.
Note:
With the device positioned on
the right, one pack consists of a
climate control door for installing
in the right side of the enclosure,
and a lockable door for the left.
With the device positioned on
the left, one pack consists of a
climate control door for installing
on the left side of the enclosure.
The existing lockable door on
the right may be used.
Climate control doors for single-
door TS8 modular enclosures,
see pages 26 – 30.
Also required:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Automatic condensate
evaporation.
Certifications,
see page 8.
Detailed drawing,
see page 120.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Property rights:
German patent no. 196 09 794
European patent no. 0 886 994
with validity for ES, FR, GB, IT,
NL, SE
Taiwanese patent no. N 11 05 287
US patent no. 6,134,109
South Korean patent
no. 0 299 406
Japanese patent no. 3 295 093
B = Width
T = Depth
For 600 mm (23.6˝) deep TS8 modular enclosures, useful cooling capacity 1200/1450 W (4098/4952 BTU)
Climate Control Sidewalls
31Climate Control
B
4.1
Climate Control Sidewalls
T
B2
B1
H2
H1
B = Width
T = Depth
Configuration:
Climate control sidewall with
pre-fitted cooling module. Also required:
Base/plinth, 100 or 200 mm
(3.9 or 7.9˝) high.
Optionally available:
Microcontroller control with:
●Digital temperature indicator,
●Floating contact for collective
fault signal,
●Connection for door operated
switch for start-up delay,
●Automatic condensate
evaporation.
Certifications,
see page 8.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. SK 3331.116 3331.316 3331.1401) 3331.3401) 3331.2161) 3331.416 3331.2401) 3331.4401)
Voltage V, Hz 230, 50/60 400, 2~, 50/60 230, 50/60 400, 2~, 50/60
Dimensions in mm (inches)
H1
H2
B1
B2
T
1797 (70.7)
1782 (70.2)
171 (6.7)
157 (6.2)
562 (22.1)
1997 (78.6)
1982 (78.1)
171 (6.7)
157 (6.2)
562 (22.1)
1797 (70.7)
1782 (70.2)
171 (6.7)
157 (6.2)
562 (22.1)
1997 (78.6)
1982 (78.1)
171 (6.7)
157 (6.2)
562 (22.1)
1797 (70.7)
1782 (70.2)
171 (6.7)
157 (6.2)
562 (22.1)
1997 (78.6)
1982 (78.1)
171 (6.7)
157 (6.2)
562 (22.1)
1797 (70.7)
1782 (70.2)
171 (6.7)
157 (6.2)
562 (22.1)
1997 (78.6)
1982 (78.1)
171 (6.7)
157 (6.2)
562 (22.1)
Dimensions to fit
TS8 modular enclosures
in mm (inches)
H
T
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
Useful cooling
capacity QK
to DIN 3168 in W (BTU)
L 35 L 35
L 35 L 50 1100/1200 (3756/4098)
730/830 (2493/2835) 1400/1450 (4781/4952)
1010/1060 (3449/3620)
Maximum rated current 4.0 A/4.6 A 2.3 A/2.7 A 4.0 A/4.6 A 2.3 A/2.7 A
Starting current 11.0 A/12.0 A 6.4 A/6.9 A 11.0 A/12.0 A 6.4 A/6.9 A
Pre-fuse T 6.0 A/6.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
670 W/850 W
800 W/1000 W
690 W/870 W
820 W/1020 W
710 W/910 W
810 W/1030 W
725 W/930 W
830 W/1050 W
Cooling coefficient
ε = QK/Pel L 35 L 35 1.6 2.0 1.9
Refrigerant R134a, 825 g (29.1 oz) R134a, 875 g (30.9 oz)
Maximum allowable
operating pressure 25 bar (363 psi) 24 bar (348 psi)
Temperature and setting range +20°C to +50°C (68°F to 122°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lbs) 58 (127.9) 62 (136.7) 58 (127.9) 62 (136.7)
Color RAL 7035 (light gray)2)
Air displacement
of fans
External circuit 550 m3/h (324 cfm)
Internal circuit 275 m3/h (162 cfm)
Temperature control Internal thermostat (factory setting +35°C (95°F))
Accessories PU Page
Metal filters 1 3289.200 112
Door-operated switch 1 4127.000 –
Temperature indicator 1 3114.100 103
Air diverter 1 3213.300 102
1) Delivery times available on request.
2) RAL 7032 (pebble gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Roof-Mounted Air Conditioners
Useful cooling capacity 510/810 W (1742/2766 BTU)
32 Climate Control
B
4.1
Roof-Mounted Air Conditioners
375
597
415
475
260
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
Note:
Air conditioners with comfort
controller may be integrated into
a superordinate remote monitor-
ing system with an optional
interface board SK 3124.200
(RS 232, RS 485, RS 422 and
PLC interface).
Accessories:
Roof plate for TS8 modular
enclosure with mounting cutout,
see page 107.
Optionally available:
With automatic condensate
evaporation.
Certifications,
see pages 9/10.
Detailed drawing,
see page 121.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3382.100 3382.110 3359.100 3359.110 3359.140
Part No. SK with comfort controller, RAL 7035 (light gray) 3382.500 3382.510 3359.500 3359.510 3359.540
Part No. SK with basic controller, stainless steel1) 3382.200 3382.210 3359.200 3359.210 3359.240
Part No. SK with comfort controller, stainless steel1) 3382.600 3382.610 3359.600 3359.610 3359.640
Voltage V, Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60 400, 2~, 50/60
Dimensions in mm (inches) H x W x D 415 x 597 x 375 (16.3 x 23.5 x 14.8)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 500/510 (1708/1742)
270/370 (922/1264) 750/810 (2561/2766)
545/590 (1861/2015)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 2.7 A/2.9 A 5.5 A/6.0 A 3.0 A/3.9 A 6.0 A/7.8 A 1.7 A/2.2 A
Starting current 9.2 A/10.2 A 18.4 A/18.4 A 10.0 A/10.7 A 20.0 A/21.4 A 5.8 A/6.2 A
Pre-fuse T 10.0 A/10.0 A 10.0 A/10.0 A 10.0 A/10.0 A 16.0 A/16.0 A 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
360 W/410 W
410 W/450 W
370 W/420 W
420 W/470 W
410 W/520 W
490 W/600 W
420 W/535 W
500 W/615 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.4 1.8
Refrigerant R134a, 250 g (8.8 oz) R134a, 300 g (10.6 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 30 (66.1) 35 (77.1) 32 (70.5) 37 (81.5)
Air displacement of fans
(unimpeded air flow)
External circuit 910 m3/h (536 cfm)
Internal circuit 440 m3/h (259 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.500 111
Metal filters 1 3286.510 112
Quick-change frame 1 3286.700 108
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Air ducting system 1 3286.870 101
Cover stoppers for interior air outlet 2 3286.780 101
Condensate hose 1 3301.612 108
1) Delivery times on request.
Special voltages available on request. Technical modifications reserved.
.
.
Accessories Page 100
Property rights:
German registered design
no. 402 02 324
German registered design
no. 402 02 325
Useful cooling capacity 1080 W (3688 BTU)
Roof-Mounted Air Conditioners
33Climate Control
B
4.1
Roof-Mounted Air Conditioners
475
597
415
490
390
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Accessories:
Roof plate for TS8 modular
enclosure with mounting cutout,
see page 107.
Optionally available:
With automatic condensate
evaporation.
Certifications,
see pages 9/10.
Detailed drawing,
see page 121.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3383.100 3383.110 3383.140
Part No. SK with comfort controller, RAL 7035 (light gray) 3383.500 3383.510 3383.540
Part No. SK with basic controller, stainless steel1) 3383.200 3383.210 3383.240
Part No. SK with comfort controller, stainless steel1) 3383.600 3383.610 3383.640
Voltage V, Hz 230, 50/60 115, 50/60 400, 2~, 50/60
Dimensions in mm (inches) H x W x D 415 x 597 x 475 (16.3 x 23.5 x 18.7)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1000/1080 (3415/3688)
760/820 (2596/2800)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 4.3 A/4.5 A 8.3 A/8.7 A 2.4 A/2.4 A
Starting current 15.5 A/15.5 A 25.3 A/24.3 A 8.0 A/8.8 A
Pre-fuse T 10.0 A/10.0 A 16.0 A/16.0 A 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
550 W/650 W
660 W/750 W
580 W/660 W
670 W/755 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.8
Refrigerant R134a, 500 g (17.6 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 40 (88.2) 46 (101.4) 46 (101.4)
Air displacement of fans External circuit 1760 m3/h (1036 cfm)
Internal circuit 440 m3/h (259 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.500 111
Metal filters 1 3286.510 112
Quick-change frame 1 3286.800 108
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Air ducting system 1 3286.870 101
Cover stoppers for interior air outlet 2 3286.880 101
Condensate hose 1 3301.612 108
1) Delivery times on request.
Special voltages available on request. Technical modifications reserved.
.
.
Accessories Page 100
Property rights:
German registered design
no. 402 02 324
German registered design
no. 402 02 325
Roof-Mounted Air Conditioners
Useful cooling capacity 1200 W (4098 BTU)
34 Climate Control
B
4.1
Roof-Mounted Air Conditioners
475
597
415
490
390
Designed for office applica-
tions. Low noise level (consider-
ably quieter than air condition-
ers for industrial applications).
Configuration:
Fully wired ready for connection,
including automatic condensate
evaporation, drilling template
and assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Accessories:
Roof plate for TS8 modular
enclosures with mounting
cutout, see page 107.
Certifications,
see page 9.
Detailed drawing,
see page 121.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with comfort controller 3273.500 3273.5151)
Voltage V, Hz 230, 50/60 115, 50/60
Dimensions in mm (inches) H x W x D 415 x 597 x 475 (16.3 x 23.5 x 18.7)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1100/1200 (3756/4098)
850/870 (2903/2971)
Rated current maximum 5.2 A/5.4 A 11.0 A/11.5 A
Starting current 15.5 A/16.5 A 32.0 A/35.0 A
Pre-fuse T 10.0 A/10.0 A 20.0 A/20.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
890 W/910 W
960 W/1100 W
920 W/940 W
990 W/1140 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.2
Refrigerant R134a, 700 g (24.7 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)2)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 42 (92.6) 47 (103.6)
Color RAL 7035 (light gray)
Air displacement of fans External circuit 1760 m3/h (1036 cfm)
Internal circuit 440 m3/h (259 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.100 111
Metal filters 1 3286.210 112
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Air-ducting system 1 3286.870 101
Cover stoppers for interior air outlet 2 3286.980 101
Condensate hose 1 3301.612 108
1) Delivery times available on request.
2) In order to avoid increased condensation, we recommend enclosures with a ratings of at least IP 54 (NEMA 12).
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Property rights:
German registered design
no. 402 02 324
German registered design
no. 402 02 325
Useful cooling capacity 1520/2130 W (5191/7274 BTU)
Roof-Mounted Air Conditioners
35Climate Control
B
4.1
Roof-Mounted Air Conditioners
475
597
415
490
390
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Accessories:
Roof plate for TS8 modular
enclosure with mounting cutout,
see page 107.
Optionally available:
With automatic condensate
evaporation.
Certifications,
see pages 9/10.
Detailed drawing,
see page 121.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3384.100 3384.110 3384.140 3385.100 3385.110 3385.140
Part No. SK with comfort controller, RAL 7035 (light gray) 3384.500 3384.510 3384.540 3385.500 3385.510 3385.540
Part No. SK with basic controller, stainless steel1) 3384.200 3384.210 3384.240 3385.200 3385.210 3385.240
Part No. SK with comfort controller, stainless steel1) 3384.600 3384.610 3384.640 3385.600 3385.610 3385.640
Voltage V, Hz 230, 50/60 115, 50/60 400, 2~, 50/60 230, 50/60 115, 50/60 400, 2~,50/60
Dimensions in mm (inches) H x W x D 415 x 597 x 475 (16.3 x 23.5 x 18.7) 415 x 597 x 475 (16.3 x 23.5 x 18.7)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1500/1520 (5123/5191)
1100/1210 (3757/4132) 2000/2130 (6830/7274)
1570/1670 (5362/5703)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 5.7 A/6.8 A 12.5 A/14.1 A 3.4 A/4.0 A 5.7 A/6.6 A 13.0 A/14.2 A 3.3 A/3.8 A
Starting current 16.6 A/17.1 A 30.7 A/29.1 A 9.8 A/9.6 A 16.8 A/18.4 A 36.0 A/32.0 A 10.0 A/12.0 A
Pre-fuse T 10.0 A/10.0 A 20.0 A/20.0 A 10.0 A/10.0 A 10.0 A/10.0 A 20.0 A/20.0 A 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
815 W/930 W
950 W/1090 W
850 W/950 W
1000 W/1150 W
1000 W/1175 W
1100 W/1310 W
1050 W/1250 W
1160 W/1380 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.8 2.0
Refrigerant R134a, 500 g (17.6 oz) R134a, 950 g (33.5 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 41 (90.3) 47 (103.6) 47 (103.6) 42 (92.6) 48 (105.8) 48 (105.8)
Air displacement of fans External circuit 1760 m3/h (1036 cfm) 1820 m3/h (1071 cfm)
Internal circuit 470 m3/h (277 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.500 111
Metal filters 1 3286.510 112
Quick-change frame 1 3286.800 108
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Air ducting system 1 3286.870 101
Cover stoppers for interior air outlet 2 3286.880 101
Condensate hose 1 3301.612 108
1) Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Property rights:
German registered design
no. 402 02 324
German registered design
no. 402 02 325
Roof-Mounted Air Conditioners
Useful cooling capacity 3300/4200 W (11,270/14,344 BTU)
36 Climate Control
B
4.1
Roof-Mounted Air Conditioners
580
796
470
692
392
Configuration:
Fully wired ready for connection,
including drilling template,
eyebolt and assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Accessories:
Roof plate for TS8 modular
enclosures with mounting
cutout, see page 107.
Optionally available:
With automatic condensate
evaporation.
Certifications,
see pages 9/10.
Detailed drawing,
see page 121.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3386.140 3387.140
Part No. SK with comfort controller, RAL 7035 (light gray) 3386.540 3387.540
Part No. SK with basic controller, stainless steel1) 3386.240 3387.240
Part No. SK with comfort controller, stainless steel1) 3386.640 3387.640
Voltage V, Hz 400, 50/460, 60, 3~ 400, 50/460, 60, 3~
Dimensions in mm (inches) H x W x D 470 x 796 x 580 (18.5 x 31.3 x 22.8) 470 x 796 x 580 (18.5 x 31.3 x 22.8)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 3000/3300 (10,246/11,270)
2460/2750 (8401/9392) 4000/4200 (13,661/14,344)
3250/3490 (11,099/11,919)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 3.0 A/3.1 A 3.5 A/3.6 A
Starting current 8.0 A/9.0 A 17.0 A/19.0 A
Pre-fuse T Motor circuit breaker 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
1180 W/1490 W
1430 W/1770 W
1620 W/2060 W
1870 W/2340 W
Cooling coefficient ε = QK/Pel L 35 L 35 2.5
Refrigerant R134a, 1600 g (56.4 oz) R134a, 1800 g (63.5 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 70 (154.3) 77 (169.8)
Air displacement of fans External circuit 3450 m3/h (2031 cfm) 3870 m3/h (2278 cfm)
Internal circuit 1280 m3/h (753.4 cfm) 1420 m3/h (836 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.600 111
Metal filters 1 3286.610 112
Quick-change frame 1 3286.900 108
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Air ducting system 1 3286.970 101
Cover stoppers for interior air outlet 2 3286.980 101
Condensate hose 1 3301.612 108
1) Delivery times on request.
Special voltages available on request. Technical modifications reserved.
.
.
Accessories Page 100
Property rights:
German registered design
no. 402 02 324
German registered design
no. 402 02 325
VIP small air conditioners, useful cooling capacity 270 W (922 BTU)
Wall-Mounted Air Conditioners
37Climate Control
B
4.1
Wall-Mounted Air Conditioners
526
353.5
288
465
105
32
183
296
288
465
183
32
353.5
296
105
1
1
60
60
The new VIP small air condition-
ers were developed especially
for cooling the VIP 6000 com-
mand panel. In addition, VIP
small air conditioners offer a
space-saving, economical solu-
tion for the climate control of
small enclosures where low heat
loads are generated by the sys-
tem.
Configuration:
Fully wired, ready for connection
and pre-mounted on an alumi-
num rear-wall to fit VIP 6000
operating housing 7 U.
Property rights:
German patent
no. 198 17 917
Distance from installed
equipment at least 60 mm
(2.4˝)
Certifications,
see page 10.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
1
Part No. SK 3201.100 3202.100
Condenser version left right
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
W
D
353.5 (13.9)
526 (20.7)
105 (4.1)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 45 225/270 (768/922)
160/200 (546/683)
Rated current maximum 1.5 A/1.5 A
Starting current 1.9 A/2.0 A
Pre-fuse T 4.0 A/4.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 45
285 W/300 W
315 W/325 W
Cooling coefficient ε = QK/Pel L 35 L 35 0.8/0.9
Refrigerant R134a, 170 g (6.0 oz)
Maximum allowable operating pressure 27 bar (392 psi)
Temperature and setting range +20°C to +45°C (68°F to 113°F)
Ratings
to EN 60 529/10.91
External circuit IP 24 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lb) 10.5 (23.1)
Color Rear wall aluminum, vent grille RAL 7035 (light gray)
Air displacement of fans External circuit 235 m3/h / 270 m3/h (138/159 cfm)
Internal circuit 160 m3/h / 180 m3/h (94/106 cfm)
Temperature control Electronic control (factory setting +35°C (95°F))
Accessories PU Page
Temperature indicator 1 3114.100 103
Condensate hose 1 3301.608 108
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Wall-Mounted Air Conditioners
Mini air conditioner in horizontal format, useful cooling capacity 320 W (1093 BTU)
38 Climate Control
B
4.1
Wall-Mounted Air Conditioners
340
525
153
98
55
Mini air conditioners in horizon-
tal format, ideal for cooling small
equipment and operating hous-
ings with optimum space utiliza-
tion.
Configuration:
Fully wired ready for connec-
tion, including drilling template
and assembly parts.
Certifications,
see page 10.
Detailed drawing,
see page 122.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK 3302.300 3302.310
Voltage V, Hz 230, 50/60 115, 60
Dimensions in mm (inches)
H
W
D
340 (13.4)
525 (20.7)
153 (6.0)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 300/320 (1025/1093)
150/160 (512/546)
Rated current maximum 1.6 A/1.7 A 3.3 A
Starting current 4.3 A/5.3 A 8.0 A
Pre-fuse T 10 A/10 A 10 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
285 W/300 W
320 W/340 W
290 W
340 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.1
Refrigerant R134a, 100 g (3.5 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 13 (28.7)
Color RAL 7035 (light gray)
Air displacement of fans External circuit 345 m3/h (203 cfm)
Internal circuit 310 m3/h (182 cfm)
Temperature control Basic controller
Accessories PU Page
Temperature indicator 1 3114.100 103
Condensate hose 1 3301.608 108
Filter mats 3 3286.110 111
Metal filters 1 3286.120 112
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Useful cooling capacity 320/610 W (1093/2080 BTU)
Wall-Mounted Air Conditioners
39Climate Control
B
4.1
Wall-Mounted Air Conditioners
T2
42
550
T
280
100
100
1
Configuration:
Fully wired ready for connec-
tion, including drilling template
and assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Partial internal mounting
possible with 3303.XXX
only.
Certifications,
see page 10.
Detailed drawing,
see page 122.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Property rights:
German registered designs
no. 402 02 324 and
no. 402 02 325
Japanese registered design
no. 1 187 896
Indian registered design
no. 189 953
US design patent no. D 488,480
IR reg. design no. DM/061 967
with validity for FR, IT, ES
1
Part No. SK with basic controller, RAL 7035 (light gray) 3302.100 3302.110 3303.100 3303.110
Part No. SK with comfort controller, RAL 7035 (light gray) – – 3303.500 3303.510
Part No. SK with basic controller, stainless steel1) 3302.200 3302.210 3303.200 3303.210
Part No. SK with comfort controller, stainless steel1) – – 3303.600 3303.610
Voltage V, Hz 230, 50/60 115, 60 230, 50/60 115, 60
Dimensions in mm (inches)
H
B
T
T2
550 (21.7)
280 (11.0)
140 (5.5)
98 (3.9)
550 (21.7)
280 (11.0)
200 (7.9)
158 (6.2)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 300/320 (1025/1093)
150/170 (512/581) 320 (1093)
170 (581) 500/610 (1708/2083)
280/350 (957/1195) 610 (2083)
350 (1195)
Rated current maximum 1.6 A/1.7 A 3.3 A 2.6 A/2.6 A 5.7 A
Starting current 3.0 A/3.4 A 8.0 A 5.1 A/6.4 A 11.5 A
Pre-fuse T 10.0 A/10.0 A 10.0 A 10.0 A/10.0 A 10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
245 W/255 W
255 W/275 W
290 W
340 W
360 W/380 W
420 W/390 W
470 W
500 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.2 1.4
Refrigerant R134a, 100 g (3.5 oz) R134a, 170 g (6.0 oz)
Maximum allowable operating pressure 25 bar (263 psi) 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 13 (28.7) 17 (37.5)
Air displacement of fans External circuit 310 m3/h (182 cfm) 345 m3/h (203 cfm)
Internal circuit 345 m3/h (203 cfm) 310 m3/h (182 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.300 111
Metal filters 1 3286.310 112
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 – 3124.100 106
RiDiag II including cables for comfort controller 1 – 3159.100 –
Interface card for comfort controller 1 – 3124.200 105
Condensate hose 1 3301.608 3301.610 108
1) Delivery times on request.
Special voltages available on request. Technical modifications reserved.
.
.
Accessories Page 100
B = Width
T = Depth
Wall-Mounted Air Conditioners
Useful cooling capacity 780 W (2664 BTU)
40 Climate Control
B
4.1
Wall-Mounted Air Conditioners
235
45
550
280
280
125
155
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
Note:
Air conditioners with comfort
controller may be integrated into
a superordinate remote monitor-
ing system with an optional inter-
face board SK 3124.200
(RS 232, RS 485, RS 422 and
PLC interface).
Certifications,
see page 11.
Detailed drawing,
see page 122.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Property rights:
German registered designs
no. 402 02 324 and
no. 402 02 325
Japanese registered design
no. 1 187 896
Indian registered design
no. 189 953
US design patent no. D 488,480
IR reg. design no. DM/061 967
with validity for FR, IT, ES
Part No. SK with basic controller, RAL 7035 (light gray) 3361.100 3361.110 3361.140
Part No. SK with comfort controller, RAL 7035 (light gray) 3361.500 3361.510 3361.540
Part No. SK with basic controller, stainless steel1) 3361.200 3361.210 3361.240
Part No. SK with comfort controller, stainless steel1) 3361.600 3361.610 3361.640
Voltage V, Hz 230, 50/603) 115, 603) 4002), 2~, 50/603)
Dimensions in mm (inches)
H
W
D
550 (21.7)
280 (11.0)
280 (11.0)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 750/780 (2561/2664)
510/540 (1742/1844) 750/780 (2561/2664)
500/540 (1708/1844) 750/780 (2561/2664)
510/540 (1742/1844)
Rated current maximum 2.3 A/2.4 A 6.5 A 1.3 A/1.4 A
Starting current 5.7 A/5.7 A 13.9 A 3.3 A/3.3 A
Pre-fuse T 10 A/10 A 10 A 10 A/10 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
480 W/555 W
545 W/610 W
560 W
650 W
490 W/570 W
560 W/630 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.5
Refrigerant R134a, 280 g (9.9 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 22 (48.5)
Air displacement of fans
(unimpeded air flow)
External circuit 480 m3/h (283 cfm)
Internal circuit 600 m3/h (353 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.300 111
Metal filters 1 3286.310 112
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Condensate hose 1 3301.608 108
1) Delivery times on request.
2) External toroidal core transformer Ø 126 x 65 mm (5.0 x 2.6˝) deep for mounting in the enclosure.
3) Tu maximum = 52°C (125°F)/60 Hz.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Useful cooling capacity 1060/1510 W (3620/5150 BTU)
Wall-Mounted Air Conditioners
41Climate Control
B
4.1
Wall-Mounted Air Conditioners
105
155
210
50
950
260
400
Configuration:
Fully wired ready for connec-
tion, including drilling template
and assembly parts.
Note:
Integration of the air conditioner
with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Optionally available:
With automatic condensate
evaporation.
Certifications,
see page 11.
Detailed drawing,
see page 123.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3304.100 3304.110 3304.140 3305.100 3305.110 3305.140
Part No. SK with comfort controller, RAL 7035 (light gray)
3304.500 3304.510 3304.540 3305.500 3305.510 3305.540
Part No. SK with basic controller, stainless steel 3304.200 3304.210 3304.240 3305.200 3305.210 3305.240
Part No. SK with comfort controller, stainless steel 3304.600 3304.610 3304.640 3305.600 3305.610 3305.640
Voltage V, Hz 230, 50/60 1151), 50/60 400, 50/
460, 60, 3~ 230, 50/60 1151), 50/60 400, 50/
460, 60, 3~
Dimensions in mm (inches)
H
W
D
950 (37.4)
400 (15.7)
260 (10.2)
950 (37.4)
400 (15.7)
260 (10.2)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1000/1060 (3415/3620)
790/840 (2698/2869) 1500/1510 (5123/5157)
1230/1250 (4201/4269)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 4.8 A/4.4 A 9.5 A/10.0 A 2.5 A/2.6 A 5.4 A/6.0 A 11.0 A/12.5 A 2.3 A/2.6 A
Starting current 12.0 A/14.0 A 26.0 A/28.0 A 11.5 A/12.7 A 22.0 A/24.0 A 42.0 A/46.0 A 12.2 A/11.3 A
Pre-fuse T 10.0 A/10.0 A 16.0 A/16.0 A 10.0 A/10.0 A2) 16.0 A/16.0 A 20.0 A/20.0 A 10.0 A/10.0 A2)
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
700 W/650 W
750 W/710 W
725 W/680 W
780 W/750 W
580 W/550 W
660 W/680 W
850 W/1000 W
1000 W/1160 W
880 W/1050 W
1040 W/1200 W
800 W/980 W
960 W/1150 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.4 1.7 1.8 1.7 1.9
Refrigerant R134a, 500 g (17.6 oz) R134a, 600 g (21.2 oz)
Maximum allowable operating pressure 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 39 (86.0) 44 (97.0) 40 (88.2) 41 (90.3) 46 (101.4) 42 (92.6)
Air displacement of fans External circuit 900 m3/h (530 cfm)
Internal circuit 600 m3/h (353 cfm) 800 m3/h (471 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.400 111
Metal filters 1 3286.410 112
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Condensate hose 1 3301.612 108
1) Delivery times available on request.
2) Motor circuit-breaker
Optionally available with automatic condesate evaporation. Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Property rights:
German registered design
no. 402 02 325
IR reg. design no. DM/062 557
with validity for FR, IT, ES
Indian registered design
no. 190 269
Japanese registered design
no. 1 187 905
Wall-Mounted Air Conditioners
Useful cooling capacity 2350/2750 W (8026/9392 BTU)
42 Climate Control
B
4.1
Wall-Mounted Air Conditioners
Part No. SK with basic contr., RAL 7035 (light gray) 3328.100 3328.110 3328.140 3329.100 3329.110 3329.140
Part No. SK with comfort contr., RAL 7035 (light gray)
3328.500 3328.510 3328.540 3329.500 3329.510 3329.540
Part No. SK with basic controller, stainless steel1) 3328.200 3328.210 3328.240 3329.200 3329.210 3329.240
Part No.
SK with comfort controller, stainless steel
1) 3328.600 3328.610 3328.640 3329.600 3329.610 3329.640
Voltage V, Hz 230, 50/60 115, 50/60 400, 50/
460, 60, 3~ 230, 50/60 115, 50/60 400, 50/
460, 60, 3~
Dimensions in mm (inches)
H
W
D
1580 (62.2)
400 (15.7)
290 (11.4)
1580 (62.2)
400 (15.7)
290 (11.4)
Useful cooling capacity QK
to DIN 3168 in W (BTU)
L 35 L 35
L 35 L 50
2000/2350 (6830/8026)
1450/1690 (4952/6771)
2500/2750 (8537/9392)
1600/1750 (5464/5977)
2500/2700
(8537/9392)
1900/1950
(6489/6660)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 6.9 A/8.5 A 13.6 A/16.2 A 2.5 A/3.0 A 8.0 A/10.0 A 16.0 A/21.0 A 3.4 A/3.5 A
Starting current 22.0 A/26.0 A 36.0 A/39.0 A 6.5 A/7.5 A 21.0 A/21.0 A 44.0 A/42.0 A 6.5 A/7.3 A
Pre-fuse T 16.0 A/16.0 A 25.0 A/25.0 A 10.0 A/10.0 A2) 16.0 A/16.0 A 25.0 A/25.0 A 10.0 A/10.0 A2)
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
900 W/1070 W
1130 W/1220 W
960 W/1130 W
1170 W/1290 W
930 W/1150 W
1150 W/1400 W
1320 W/1550 W
1500 W/1880 W
1380 W/1600 W
1550 W/1940 W
1300 W/1500 W
1550 W/1850 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.7 2.3 1.9 2.0
Refrigerant R134a, 950 g (33.5 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 66 (145.5) 73 (160.9) 67 (147.7) 69 (152.1) 76 (167.6) 70 (154.3)
Air displacement of fans External circuit 640 m3/h (377 cfm) 710 m3/h (418 cfm)
Internal circuit 550 m3/h (324 cfm) 640 m3/h (377 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.400 111
Metal filters 1 3286.410 112
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II incl. cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Condensate hose 1 3301.612 108
1) Delivery times available on request. 2) Motor circuit-breaker
Optionally available with automatic condesate evaporation. Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
400
40
1580
295
145
150
245
50
Configuration:
Fully wired ready for connec-
tion, including drilling template,
eyebolt and assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Optionally available:
With automatic condensate
evaporation.
Also required:
For installation in the door, the
use of a ride-up roller is recom-
mended.
Certifications,
see page 11.
Detailed drawing,
see page 123.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Useful cooling capacity 4400 W (15,027 BTU)
Wall-Mounted Air Conditioners
43Climate Control
B
4.1
Wall-Mounted Air Conditioners
1580
340
500
145
195
Configuration:
Fully wired ready for connec-
tion, including drilling template,
eyebolt and assembly parts.
Note:
Integration of the air condition-
ers with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Optionally available:
With automatic condensate
evaporation.
Also required:
For installation in the door, the
use of a ride-up roller is
recommended.
Certifications,
see page 11.
Detailed drawing,
see page 123.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3332.140
Part No. SK with comfort controller, RAL 7035 (light gray) 3332.540
Part No. SK with basic controller, stainless steel1) 3332.240
Part No. SK with comfort controller, stainless steel1) 3332.640
Voltage V, Hz 400, 50/460, 60, 3~
Dimensions in mm (inches)
H
W
D
1580 (62.2)
500 (19.7)
340 (13.4)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 4000/4400 (13,661/15,027)
3070/3570 (10,485/12,192)
To order air conditioners with integrated condensate evaporators, add .XX1 to the part number, ie. XXXX.XX1.
Rated current maximum 3.8 A/3.9 A
Starting current 9.2 A/11.0 A
Pre-fuse T Motor circuit breaker 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
1710 W/2110 W
1980 W/2450 W
Cooling coefficient ε = QK/Pel L 35 L 35 2.3
Refrigerant R134a, 3000 g (105.8 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 91 (200.6)
Air displacement of fans External circuit 2000 m3/h (1177 cfm)
Internal circuit 1500 m3/h (883 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.400 111
Metal filters 1 3286.410 112
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Condensate hose 1 3301.612 108
1) Delivery times available on request.
Optionally available with automatic condesate evaporation. Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Wall-Mounted Air Conditioners
Slimline, useful cooling capacity 1500 W (5123 BTU)
44 Climate Control
B
4.1
Wall-Mounted Air Conditioners
1580
195
450
140
55
1580
165
450
140
25
The super slimline design per-
mits system adaptation for appli-
cations where high heat loads
are accommodated in a con-
fined space.
Configuration:
Fully wired ready for connection,
including drilling template and
assembly parts.
Note:
Air conditioner with comfort con-
troller may be integrated into a
superordinate remote monitor-
ing system with an optional inter-
face board SK 3124.200
(RS 232, RS 485, RS 422 and
PLC interface).
Optionally available:
With automatic condensate
evaporation.
Certifications,
see page 12.
Detailed drawing,
see page 124.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller, RAL 7035 (light gray) 3366.100 3377.1001) 3366.110 3377.1101) 3366.140 3377.1401)
Part No. SK with comfort controller, RAL 7035 (light gray) 3366.500 3377.5001) 3366.510 3377.5101) 3366.540 3377.5401)
Part No. SK with basic controller, stainless steel 3366.2001) 3377.2001) 3366.2101) 3377.2101) 3366.2401) 3377.2401)
Part No. SK with comfort controller, stainless steel 3366.6001) 3377.6001) 3366.6101) 3377.6101) 3366.6401) 3377.6401)
Voltage V, Hz 230, 50/60 115, 50/60 400/460, 3~, 50/60
Dimensions in mm (inches)
H
W
D
1580 (62.2)
450 (17.7)
195 (7.7)
1580 (62.2)
450 (17.7)
165 (6.5)
1580 (62.2)
450 (17.7)
195 (7.7)
1580 (62.2)
450 (17.7)
165 (6.5)
1580 (62.2)
450 (17.7)
195 (7.7)
1580 (62.2)
450 (17.7)
165 (6.5)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1500/1500 (3415/5123)
1050/1100 (3586/3757)
Rated current maximum 6.5 A/6.7 A 13.2 A/13.6 A 2.6 A/2.8 A
Starting current 22.0 A/24.0 A 43.0 A/47.0 A 8.0 A/8.8 A
Pre-fuse T 10.0 A/10.0 A 20.0 A/20.0 A 10.0 A/10.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
920 W/1050 W
1095 W/1210 W
950 W/1080 W
1140 W/1250 W
950 W/1100 W
1120 W/1290 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.6
Refrigerant R134a, 700 g (24.7 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 45 (99.2) 50 (110.2) 46 (101.4)
Air displacement of fans
(unimpeded air flow)
External circuit 910 m3/h (536 cfm)
Internal circuit 860 m3/h (506 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.400 3253.010 3286.400 3253.010 3286.400 3253.010 111
Metal filters 1 3286.410 3253.220 3286.410 3253.220 3286.410 3253.220 112
Trim frame for external mounting 1 3377.000 107
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Condensate hose 1 3301.612 108
1) Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Accessories Page 100
Design NEMA 4X, useful cooling capacity 610/1510 W (2083/5150 BTU)
Wall-Mounted Air Conditioners
45Climate Control
B
4.1
Wall-Mounted Air Conditioners
238
298
285
620
298
358
405
1020
Configuration:
Fully wired ready for connec-
tion, including drilling template
and assembly parts.
Note:
Air conditioner with comfort con-
troller may be integrated into a
superordinate remote monitor-
ing system with an optional inter-
face board SK 3124.20 (RS 232,
RS 485, RS 422 and PLC inter-
face).
Certifications,
see page 12.
Detailed drawing,
see page 124.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller1) 3303.104 3303.114 3304.104 3304.114 3304.144 3305.104 3305.114 3305.144
Part No. SK with comfort controller1) 3303.504 3303.514 3304.504 3304.514 3304.544 3305.504 3305.514 3305.544
Voltage V, Hz 230, 50/60 115, 60 230, 50/60 115, 50/60 400, 50/
460, 60, 3~ 230, 50/60 115, 50/60 400, 50/
460, 60, 3~
Dimensions
in mm (inches)
H
W
D
620 (24.4)
285 (11.2)
298 (11.7)
1020 (40.2)
405 (15.9)
358 (14.1)
1020 (40.2)
405 (15.9)
358 (14.1)
Useful cooling capacity QK
to DIN 3168 in W (BTU)
L 35 L 35
L 35 L 50
500/610
(1708/2083 )
280/350
(956/1195)
500 (1708)
280 (956)
1000/1060 (3415/3620)
790/840 (2698/2869)
1500/1510 (5123/5157)
1230/1250 (4201/4269)
Rated current maximum 2.6/2.6 A 5.7 A 4.8/4.4 A 9.5/10.0 A 2.5/2.6 A 5.4/6.0 A 11.0/12.5 A 2.3/2.6 A
Starting current 5.1/6.4 A 11.5 A 12.0/14.0 A 26.0/28.0 A 11.5/12.7 A 22.0/24.0 A 42.0/46.0 A 12.2/11.3 A
Pre-fuse T 10.0/10.0 A 10.0 A 10.0/10.0 A 16.0/16.0 A 10.0 A2) 16.0/16.0 A 20.0/20.0 A 10.0 A2)
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
360/380 W
420/390 W
470 W
500 W
700/650 W
750/710 W
725/680 W
780/750 W
580/550 W
660/680 W
850/1000 W
1000/1160 W
880/1050 W
1040/1200 W
800/980 W
960/1150 W
Cooling coefficient
ε = QK/Pel L 35 L 35 1.4 1.7 1.8 1.7 1.9
Refrigerant R134a, 170 g (6.0 oz) R134a, 500 g (17.6 oz) R134a, 600 g (21.1 oz)
Maximum allowable operating pressure 28 bar (406 psi) 25 bar (363 psi) 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings NEMA 4X
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 25 (55.1) 49 (108.2) 54 (119.0) 50 (110.2) 51 (112.4) 56 (123.5) 52 (114.6)
Material Type 304 stainless steel (V2A)
Air displacement of fans External circuit 345 m3/h (203 cfm) 900 m3/h (530 cfm) 900 m3/h (530 cfm)
Internal circuit 310 m3/h (182 cfm) 600 m3/h (353 cfm) 800 m3/h (471 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Door-operated switch 1 4127.000 4127.000 –
SK bus system
for comfort controller 1 3124.100 – 3124.100 106
RiDiag II
for comfort controller, incl. cables 1 3159.100 –
Interface card for
comfort controller 1 3124.200 105
Condensate hose 1 3301.610 3301.612 108
1) Delivery times available on request.
2) Motor circuit breaker.
Special voltages and technical modifications available on request.
.
.
Accessories Page 100
Wall-Mounted Air Conditioners
Design NEMA 4X, useful cooling capacity 2350/2750 W (8025/9392 BTU)
46 Climate Control
B
4.1
Wall-Mounted Air Conditioners
1650
328
368
405
Configuration:
Fully wired ready for connec-
tion, including drilling template
and assembly parts.
Note:
Integration of the air conditioner
with comfort controller, into a
superordinate remote monitor-
ing system, can be achieved
with an optional interface board
SK 3124.200 (RS 232, RS 485,
RS 422 and PLC interface).
Certifications,
see page 12.
Detailed drawing,
see page 125.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK with basic controller1) 3328.104 3328.114 3328.144 3329.104 3329.114 3329.144
Part No. SK with comfort controller1) 3328.504 3328.514 3328.544 3329.504 3329.514 3329.544
Voltage V, Hz 230, 50/60 115, 50/60 400, 50/
460, 60, 3~ 230, 50/60 115, 50/60 400, 50/
460, 60, 3~
Dimensions in mm (inches)
H
W
D
1650 (65.0)
405 (16.0)
368 (14.5)
Useful cooling capacity QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 2000/2350 (6860/8025)
1450/1690 (4952/5772) 2500/2750 (8538/9392)
1600/1750 (5464/5977)
Rated current maximum 6.9 A/5.0 A 13.6 A/16.2 A 2.5 A/3.0 A 8.0 A/10.0 A 16.0 A/21.0 A 3.4 A/3.5 A
Starting current 22.0 A/26.0 A 36.0 A/39.0 A 6.5 A/7.5 A 21.0 A/21.0 A 44.0 A/42.0 A 6.5 A/7.3 A
Pre-fuse T 16.0 A/16.0 A 25.0 A/25.0 A 10.0 A/10.0 A2) 16.0 A/16.0 A 25.0 A/25.0 A 10.0 A/10.0 A2)
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
900/1070 W
1330/1220 W
960/1130 W
1170/1290 W
930/1150 W
1150/1400 W
1320/1550 W
1500/1880 W
1380/1600 W
1550/1980 W
1300/1500 W
1550/1850 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.7 2.3 1.9 2.0
Refrigerant R134a, 900 g (31.7 oz)
Maximum allowable operating pressure 28 bar (406 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Ratings NEMA 4X
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 80 (176.4) 87 (191.8) 80 (176.4) 83 (183.0) 90 (198.4) 83 (183.0)
Material Type 304 stainless steel (V2A)
Air displacement of fans External circuit 640 m3/h (377 cfm) 710 m3/h (418 cfm)
Internal circuit 550 m3/h (324 cfm) 640 m3/h (377 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
RiDiag II
including cables for comfort controller 1 3159.100 –
Interface card for comfort controller 1 3124.200 105
Condensate hose 1 3301.612 108
1) Delivery times available on request.
2) Motor circuit-breaker
Special voltages and technical modifications available on request.
.
.
Accessories Page 100
47
RiNano
Increased value, lower costs
Climate Control
Anti-graffiti – the cleaning of CS Outdoor
enclosures will be easy with our RiNano finish.
Not all painted works can be considered art. A RiNano-finish
enhancement will make the removal of graffiti effortless. Spray-
paint can be removed with a power-washer as part of regular
cleaning. The finish repels other stains and contaminants as well.
We are confident that you will find this finish option very useful.
RiNano anti-fingerprint and anti-microbial –
the refinement of stainless steel products
These two finishes may be used individually or together.
Anti-fingerprint will make finger prints less visible, they can
easily be wiped off with a dry cloth.
The ultra-fine nano composite material will not visibly change the
appearance of the surface.
Anti-microbial, with a special silver finish, prevents the
development of microbes (viruses, bacteria, fungi).
Simple cleaning washes them off.
Ciba tested.
Please request additional information at rinano@rittal-corp.com.
TopTherm & RiNano an innovative finish
for long lasting cooling performance
Layers of dust on the outer air circuit surfaces of air conditioners
can diminish effectiveness by 30 to 50 % due to the insulating
effect. A revolutionary RiNano-finish can prevent this because of
its water, dirt and oil repelling properties; it will help provide long
lasting, consistent cooling performance. Service and maintenance
can be scheduled less frequently and cleaning will be much
easier.
Air conditioners
in W (BTU) Voltage Controller Part No. SK Standard
equipment
see page
Standard RiNano
Wall-
mounted
500 (1708) 230 V Comfort 3303.500 3303.400 39
1000 (3415) 230 V Comfort 3304.500 3304.400 41
1000 (3415) 400 – 460 V, 3~ Comfort 3304.540 3304.440 41
1500 (5123) 230 V Comfort 3305.500 3305.400 41
1500 (5123) 400 – 460 V, 3~ Comfort 3305.540 3305.440 41
Roof-
mounted
1500 (5123) 230 V Comfort 3384.500 3384.400 35
1500 (5123) 400 V, 2~ Comfort 3384.540 3384.440 35
Additional air conditioners with RiNano finish upon request.
48 Climate Control
Chiller Systems
Features
B
4.1
Chiller Systems
Chiller systems ensure centralized, efficient cooling and pro-
vision of the cooling medium (generally water). For example,
all cooling tasks on a system or machine can be solved by a
single pipeline system. Spatial separation between cooling
production and process cooling can be achieved with chiller
systems.
Installation conditions
1
4
3
3
2
1
2
2
Unity with enclosures
For example, chiller systems
may be attached directly to a
bayed enclosure suite to pro-
vide effective, centralized cool-
ing of all cases and enclosures
on a machine or plant floor.
Spatially separated
High heat loads can even be
dissipated in confined and awk-
ward spaces, due to the spatial
separation of the chiller system
from the enclosure and machine.
In all cases, as well as enclo-
sure cooling, cooling water may
also be produced for process
and machine cooling or for cool-
ing liquid media.
Chiller system
Air/water heat exchanger,
roof-mounted
Air/water heat exchanger,
wall-mounted
Further cooling options,
machine cooling
1
2
3
4
Benefits:
●A single system for enclosure
cooling, process and
machine cooling, and the
cooling of liquid media.
●Integration into bayed
enclosure suites
●Individual project planning
●Commissioning and ser-
vicing
Important:
●Cooling capacity calculated
at an ambient temperature
of 32°C (90°F) and an inlet
temperature of 10°C (50°F)
and 18°C (64°F) (water)/20°C
(68°F) (oil)
Application diversity of centralized cooling technology
Enclosure cooling
In conjunction with air/water heat
exchangers, optimum dissipa-
tion of high heat loads is guaran-
teed, even under extreme ambi-
ent temperatures and air
pollution.
Cooling of liquid media
Direct and indirect cooling of
liquids are the prerequisite for
ensuring essential machine pre-
cision and speed.
Process cooling
High-quality material process-
ing, such as laser cutting,
requires high levels of tempera-
ture precision with simultaneous
cooling of the peripheral tech-
nology.
49Climate Control
Chiller Systems
Features
B
4.1
Chiller Systems
Example 1
Production line
High-quality material process-
ing requires a high degree of
temperature precision with
simultaneous cooling of the pe-
ripheral technology. The cost-
effective cooling of various
equipment in the production
line is performed centrally by
the chiller system in an indus-
trial enclosure. It supplies the
machine, process cooling and
control enclosure with the re-
quired cooling water by an
air/water heat exchangers.
Example 2
Test laboratory
Every single product is subjec-
ted to in-depth functional and
quality testing at the in-house
test laboratory. To ensure that
the test process runs smoothly,
the control enclosures are
cooled by an air/water heat
exchanger, and the three test
benches are supplied with the
required cooling water per the
test requirements. These di-
verse cooling tasks are per-
formed by the chiller system
integrated into the TS8 modular
enclosure system. Visually, they
form a single unit with the TS8
control enclosure.
Example 3
Control room
In conjunction with air/water
heat exchangers, the server
and network enclosures in-
stalled in the production control
room are cooled by a mini
chiller system. The mini chiller
system is installed outside of
the production control room to
avoid contaminating the room
air, and to facilitate optimum
dissipation of the heat loss gen-
erated by the chiller system.
Example 4
Tool production
The heat loss generated during
tool machining, (for example by
water-cooled motor spindles
with high-frequency drives),
must be dissipated efficiently. In
this case, the task is performed
by a wall-mounted Mini chiller
system which at the same time
ensures cooling of the control
unit, also integrated into the
machine.
Project planning examples
1
2
3
4
Chiller Systems
Mini, cooling capacity 1070/1660 W (3654/5669 BTU)
50 Climate Control
B
4.1
Chiller Systems
430
600
400
Technical design:
●Compact and modular layout
of the cooling components on
a base plate which functions
as a collecting tray
●Medium-conveying pumps
●Precise temperature control,
based on microprocessor
technology
●Collective fault signal with
floating contact
●Application-specific equip-
ment available on request.
●Pressure-sealed system (.600)
or open system with tank
(.610)
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 128.
Characteristic curves of pump,
see page 128.
Options,
see page 126.
Part No. SK 3318.600 3318.610 3319.600 3319.610
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
W
D
400 (15.7)
600 (23.6)
430 (16.9)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F) in W (BTU) 780/870 (2664/2971)
960/1070 (3279/3654) 1200/1330 (4098/4542)
1490/1660 (5089/5669)
Power consumption 630/780 W 845/1050 W
Rated current maximum 4.2 A 5.4 A
Refrigerant R134a
Pmax. cooling circuit 25 bar (363 psi)
Temperature range Environment +5°C to +43°C (41°F to 109°F)
Liquid media +10°C to +30°C (14°F to 86°F)
Pump capacity See characteristic curve
Tank Pressure-sealed Made from PP plastic Pressure-sealed Made from PP plastic
Tank capacity in l (gal) – 2.5 (0.7) – 2.5 (0.7)
Water connections 2 x 1/2˝ IG
Weight in kg (lb) 48 (105.8) 51 (112.4)
Color RAL 7035 (light gray)
Ratings (electric) IP 44
Air displacement of fans 900 m3/h (530 cfm)
Temperature control Microcontroller control, setting range +10°C to +30°C (50°F to 86°F) (factory setting +18°C (64°F))
Accessories PU Page
Metal filter mat 1 3286.510 112
Customized solutions and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Mini, cooling capacity 3400/5400 W (11,612/18,442 BTU)
Chiller Systems
51Climate Control
B
4.1
Chiller Systems
635
602
676
25
Technical design:
●Compact, modular configura-
tion of the cooling compo-
nents with integrated water
tank. Operator display may be
optionally mounted on the
front or rear
●Integrated tank level display
●Medium-conveying pumps
●Precise temperature control,
based on microprocessor
technology
●Collective fault signal with
floating contact
●Application-specific equip-
ment available on request
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 128.
Characteristic curves of pump,
see page 128.
Options,
see page 126.
Part No. SK 3320.600 3334.600
Voltage V, Hz 400, 3~, 50/60/460, 3~, 601)
Dimensions in mm (inches)
H
W
D
676 (26.6)
602 (23.7)
635 (25.0)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F) in W (BTU) 2650/3000 (9050/10,246)
3000/3400 (10,246/11,612) 3900/4700 (13,319/16,051)
4500/5400 (15,368/18,442)
Power consumption 1716/1953 W 2001/2505 W
Rated current maximum 3.8 A/3.9 A 4.9 A/5.0 A
Refrigerant R134a
Pmax. cooling circuit 25 bar (363 psi)
Temperature range Environment +5°C to +43°C (41°F to 109°F)
Liquid media +10°C to +30°C (14°F to 86°F)
Pump capacity See characteristic curve
Tank Made from type 304 stainless steel
Tank capacity in l (gal) 30 (7.9)
Water connections 2 x 1/2˝ IG
Weight in kg (lb) 88 (194.0) 94 (207.2)
Color RAL 7035 (light gray)
Ratings (electric) IP 44
Air displacement of fans 1785 m3/h (1051 cfm)
Temperature control Microcontroller control, setting range +10°C to +30°C (50°F to 86°F) (factory setting +18°C (64°F))
Accessories PU Page
Metal filter mat 1 3286.520 112
1) Supports multiple voltages without rewiring.
Special voltages and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Chiller Systems
Mini, for wall-mounting, cooling capacity 1120/4500 W (3825/15,368 BTU)
52 Climate Control
B
4.1
Chiller Systems
T
H
B
T
H
B
B = Width
T = Depth
Technical design:
●Compact, modular configura-
tion of the cooling compo-
nents with integrated water
tank
●Application-specific equip-
ment available on request
●Open system with tank
Configuration:
Chiller system fully wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 129.
Characteristic curves of pump,
see page 129.
Options,
see page 126.
Part No. SK 3360.100 3360.250 3360.400
Voltage V, Hz 400, 3~, 50/60/460, 3~, 601)
Dimensions in mm (inches)
H
B
T
950 (37.4)
400 (15.7)
310 (12.2)
1580 (62.2)
400 (15.7)
290 (11.4)
1580 (62.2)
500 (19.7)
340 (13.4)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F) in W (BTU) 830/930 (2835/3176)
1000/1120 (3415/3825) 2100/2350 (7172/8026)
2500/2800 (8538/9563) 3300/3700 (11,270/12,636)
4000/4500 (13,661/15,368)
Power consumption 700/760 W 1550/2000 W 1980/2450 W
Rated current maximum 2.7 A/3.0 A 3.7 A/3.8 A 3.9 A/4.2 A
Refrigerant R134a
Pmax. cooling circuit 23 bar (334 psi)
Temperature range Environment +5°C to +43°C (41°F to 109°F)
Liquid media +10°C to +30°C (14°F to 86°F)
Pump capacity See characteristic curve
Tank Made from PP plastic
Tank capacity in l (gal) 5 (1.3) 10 (2.6) 15 (4.0)
Water connections Quick-release coupling (counterpart included in accessory bag)
Weight in kg (lb) 47 (103.6) 78 (172.0) 99 (218.3)
Color RAL 7035 (light gray)
Ratings (electric) IP 44
Air displacement of fans 500 m3/h (294 cfm) 710 m3/h (418 cfm) 2000 m3/h (1177 cfm)
Temperature control Microcontroller control, setting range +10°C to +30°C (50°F to 86°F) (factory setting +18°C (64°F))
Accessories PU Page
Filter mat 1 3286.400 111
Metal filter mat 1 3286.410 112
1) Supports multiple voltages without rewiring.
Special voltages and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Freestanding enclosure, cooling capacity 2100 to 7700 W (7172/26,297 BTU)
Chiller Systems
53Climate Control
B
4.1
Chiller Systems
T
H
B
B = Width
T = Depth
Technical design:
●Robust industrial standard in
3 enclosure sizes
●Identical basic enclosure for
oil and water chiller systems
●Extra space for the integra-
tion of special equipment
●Variable air routing is possi-
ble via the left or right sidewall
●Floating contact for collective
fault signal
●Level monitor
●Multi-coil vaporizer in the tank
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mats, castors,
eyebolts and safety modules
available on request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 129.
Characteristic curves of pump,
see page 129.
Options,
see page 126.
Part No. SK 3336.100 3336.200 3336.300 3336.500 3336.600 3336.650
Voltage V, Hz 400, 3~, 50
Dimensions in mm (inches)
H
B
T
725 (28.5)
470 (18.5)
540 (21.3)
965 (38.0)
485 (19.1)
650 (25.6)
1180 (46.5)
595 (23.4)
800 (31.5)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F)
in W (BTU)
1700 (5806)
2100 (7172) 2100 (7172)
2580 (8811) 2300 (7855)
3360 (11,475) 3550 (12,124)
5040 (17,213) 4800 (16,393)
6160 (21,038) 5200 (17,758)
7700 (26,297)
Power consumption 1.5 kW 1.8 kW 2.3 kW 2.9 kW 3.6 kW
Rated current maximum 2.8 A 3.5 A 4.2 A 4.9 A 5.7 A
Refrigerant R134a
Pmax. cooling circuit 24 bar (348 psi)
Temperature range Environment +15°C to +45°C (59°F to 113°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Pump capacity See characteristic curve
Tank Made from type 304 stainless steel
Tank capacity in l (gal) 17 (4.5) 33 (8.7) 57 (15.1)
Water connections 3/4˝ IG 1˝ IG
Weight in kg (lb) 75 (165.3) 97 (213.8) 99 (218.3) 141 (310.9) 143 (315.3) 147 (324.1)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 700 m3/h
(412 cfm)
1250 m3/h
(736 cfm)
1785 m3/h
(1050 cfm)
3140 m3/h
(1848 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +18°C (64°F))
Delivery times available on request.
Special voltages, other frequencies, and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Chiller Systems
Freestanding enclosure, cooling capacity 12600 to 32250 W (43,031/110,140 BTU)
54 Climate Control
B
4.1
Chiller Systems
T
H
B
B = Width
T = Depth
Technical design:
●Robust industrial enclosures
in 2 sizes
●Identical basic enclosure for
oil and water chiller systems
●Integration of application-spe-
cific equipment on request
●Variable air routing is possi-
ble via the left or right sidewall
●Removable sidewalls provide
easy and convenient access
to components for service and
maintenance
●Floating contact for collective
fault signal
●Bi-frequency version
(50/60 Hz)
●Flow monitor
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mats, castors, lifting
eyes and safety modules
available on request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 130.
Characteristic curves of pump,
see page 130.
Options,
see page 126.
Part No. SK 3336.700 3336.710 3336.720 3336.730 3336.740 3336.750
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Dimensions in mm (inches)
H
B
T
1178 (46.4)
615 (24.2)
1160 (45.7)
1178 (46.4)
715 (28.1)
1360 (53.5)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F)
in W (BTU)
8250/10400
(28,175/35,518)
10000/12600
(34,152/43,031)
11900/15500
(40,641/52,935)
14350/18700
(49,008/63,864)
13450/16550
(45,934/56,521)
16300/20100
(55,667/68,645)
15000/18100
(51,228/61,814)
18500/22350
(63,181/76,329)
17000/20650
(58,058/70,523)
20900/25400
(71,377/86,746)
20600/26350
(70,353/89,990)
25200/32250
(86,063/110,140)
Power consumption 3800 W/5300 W 4800 W/6500 W 5300 W/7100 W 6400 W/9000 W 7100 W/9900 W 8100 W/11500 W
Rated current maximum 10.6 A/10.8 A 13.1 A/13.3 A 14.1 A/14.3 A 16.2 A/18.4 A 18.2 A/20.4 A 19.7 A/22.4 A
Refrigerant R407C
Pmax. cooling circuit 27 bar (392 psi)
Temperature range Environment +15°C to +45°C1) (59°F to 113°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Pump capacity See characteristic curve
Tank Made from type 304 stainless steel
Tank capacity in l (gal) 60 (15.9) 100 (26.4)
Water connections 1˝ IG
Weight in kg (lb) 215 (474.0) 225 (496.0) 235 (518.1) 240 (529.1) 250 (551.2) 260 (573.2)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 6280 m3/h (3696 cfm) 10880 m3/h (6404 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +18°C (64°F))
1) SK 3336.720 and SK 3336.750 +15°C to +40°C (59°F to 104°F).
Delivery times available on request.
Special voltages and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Freestanding enclosure for oil, cooling capacity 2550 to 7900 W (8709/26,980 BTU)
Chiller Systems
55Climate Control
B
4.1
Chiller Systems
T
H
B
B = Width
T = Depth
Technical design:
●Robust industrial standard in
2 enclosure sizes
●Identical basic enclosure for
oil and water chiller systems
●Variable air routing is possi-
ble via the left or right sidewall
●High-capacity gear pump
●Floating contact for collective
fault signal
●Integration of application spe-
cific equipment on request
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mats, castors, lifting
eyes available on request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 130.
Options,
see page 126.
Part No. SK 3337.200 3337.300 3337.500 3337.600 3337.650
Voltage V, Hz 400, 3~, 50
Dimensions in mm (inches)
H
B
T
965 (38.0)
485 (19.1)
650 (25.6)
1180 (46.5)
595 (23.4)
800 (31.5)
Cooling capacity with oil ISO VG 32
Toil = 20°C (68°F)
Tu = 32°C (90°F) in W (BTU) 2550 (8708) 3400 (11,612) 5150 (17,588) 6700 (22,882) 7900 (26,980)
Power consumption 1.2 kW 1.6 kW 2.3 kW 2.8 kW 3.6 kW
Rated current maximum 3.1 A 3.7 A 4.9 A 5.4 A 5.7 A
Refrigerant R134a
Pmax. cooling circuit 24 bar (348 psi)
Temperature range Environment +15°C to +45°C (59°F to 113°F)
Liquid media +15°C to +35°C (59°F to 95°F)
Pump capacity at 10 bar 10 l/min (2.6 gal/min) 24 l/min (6.3 gal/min)
Optional tank Made from type 304 stainless steel
Optional Tank capacity in l (gal) 33 (8.7) 57 (15.1)
Connections 3/4˝ IG 1˝ IG
Weight in kg (lb) 103 (224.9) 105 (231.5) 148 (326.3) 150 (330.7) 154 (339.5)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 1250 m3/h (736 cfm) 1785 m3/h (1051 cfm) 3140 m3/h (1848 cfm)
Temperature control Electronic control with digital display, setting range +15°C to +35°C (59°F to +95°F)
(factory setting +20°C (68°F))
Delivery times available on request.
Special voltages, other frequencies, and technical modifications available on request.
Chiller Systems
Freestanding enclosure for oil, cooling capacity 10600 to 26100 W (20,201/89,136 BTU)
56 Climate Control
B
4.1
Chiller Systems
T
H
B
B = Width
T = Depth
Technical design:
●Robust industrial housing in
2 enclosure sizes
●Identical basic enclosure for
oil and water chiller systems
●Variable air routing is possi-
ble via the left or right sidewall
●Removable sidewalls provide
easy and convenient access
to components for service and
maintenance
●High-capacity gear pump
●Floating contact for collective
fault signal
●Integration of application-spe-
cific equipment on request
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mats, castors, lifting
eyes available on request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 131.
Options,
see page 126.
Part No. SK 3337.700 3337.710 3337.720 3337.730 3337.740 3337.750
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Dimensions in mm (inches)
H
B
T
1178 (46.4)
615 (24.2)
1160 (45.7)
1178 (46.4)
715 (28.1)
1360 (53.5)
Cooling capacity with oil ISO VG 32
Toil = 20°C (68°F)
Tu = 32°C (90°F) in W (BTU) 10600 (36,201)
12000 (40,982) 15150 (51,738)
17500 (59,766) 17200 (58,741)
20000 (68,304) 19250 (65,742)
22500 (76,842) 21600 (73,768)
25000 (85,379) 26100 (89,136)
30000 (102,455)
Power consumption 5300/6300 W 6400/7700 W 7100/8200 W 8700/10300 W 9600/11300 W 10500/13300 W
Rated current maximum 12 A/12 A 15 A/15 A 16 A/16 A 19 A/20 A 21 A/22 A 22 A/24 A
Refrigerant R407C
Pmax. cooling circuit 28 bar (406 psi)
Temperature range Environment +15°C to +45°C (59°F to +113°F)1)
Liquid media +15°C to +35°C (59°F to +95°F)
Pump capacity at 10 bar 45 l/min (11.9 gal/min) 68 l/min (18.0 gal/min)
Optional tank Made from type 304 stainless steel
Optional Tank capacity in l (gal) 60 (15.9) 100 (26.4)
Connections 1˝ IG
Weight in kg (lb) 222 (489.4) 232 (511.4) 242 (533.5) 248 (546.7) 258 (568.8) 268 (590.8)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 6280 m3/h (3696 cfm) 10880 m3/h (6404 cfm)
Temperature control Electronic control with digital display, setting range +15°C to +35°C (59°F to +95°F)
(factory setting +20°C (68°F))
1) SK 3337.720 and SK 3337.750 +15°C to +40°C (59°F to +104°F).
Delivery times available on request.
Special voltages, other refrigerants, and technical modifications available on request.
In TS8 modular enclosure system, cooling capacity 6000/7500 W (20,491/25,614 BTU)
Chiller Systems
57Climate Control
B
4.1
Chiller Systems
T
B
H
100
B = Width
T = Depth
Technical design:
●Compact structure with con-
trol components in the front
and air intake via the rear
●Suitable for bayed siting
●Special fittings and options
available on request
●Float-actuated switch as pro-
tection against running dry
●Floating collective fault signal
●Equipped with Grundfos
pumps and Siemens compo-
nents
●Service accessibility from all
sides
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mat and safety
module available on request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 131.
Characteristic curves of pump,
see page 131.
Options,
see page 126.
Part No. SK 3335.060 3335.075
Voltage V, Hz 400, 3~, 50
Dimensions in mm (inches)
H
B
T
2000 (78.7)
600 (23.6)
600 (23.6)
Base/plinth height in mm (inches) 100 (3.9)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F) in W (BTU) 4800 (16,393)
6000 (20,491) 6000 (20,491)
7500 (25,614)
Power consumption 2.4 kW 3.0 kW
Rated current maximum 7.6 A 8.1 A
Refrigerant R407C
Pmax. cooling circuit 24 bar (348 psi)
Temperature range Environment +10°C to +43°C (50°F to 109°F)
Liquid media +10°C to +30°C (50°F to 86°F)
Pump capacity See characteristic curve
Tank Made from PP plastic
Tank capacity in l (gal) 80 (21.1)
Water connections 3/4˝ IG
Weight in kg (lb) 180 (396.8) 190 (418.9)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 4000 m3/h (2354 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +30°C (50°F to 86°F)
(factory setting +18°C (64°F))
Delivery times available on request.
Special voltages, other frequencies and refrigerants, and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Chiller Systems
In TS8 modular enclosure system, cooling capacity 10000 to 25000 W (34,152/85,379 BTU)
58 Climate Control
B
4.1
Chiller Systems
T
H
100
B
T
B
H
100
B = Width
T = Depth
Technical design:
●Compact structure with con-
trol components in the front
and air intake via the rear
●Suitable for bayed siting
●Special fittings and options
available on request
●Float-actuated switch as pro-
tection against running dry
●Floating collective fault signal
●Magnetic valve in the cooling
circuit
●Equipped with Grundfos
pumps and Siemens compo-
nents
●Service accessibility from all
sides
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mat and safety
module available on request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 131.
Characteristic curves of pump,
see page 131.
Options,
see page 126.
Part No. SK 3335.100 3335.120 3335.150 3335.200 3335.250
Voltage V, Hz 400, 3~, 50
Dimensions in mm (inches)
H
B
T
2000 (78.7)
800 (31.5)
600 (23.6)
2000 (78.7)
1200 (47.2)
600 (23.6)
Base/plinth height in mm (inches) 100 (3.9)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F) in W (BTU) 8000 (27,321)
10000 (34,152) 10000 (34,152)
12000 (40,982) 11500 (39,275)
15000 (51,228) 17000 (58,058)
20000 (68,304) 22000 (75,134)
25000 (85,379)
Power consumption 4.0 kW 4.8 kW 6.0 kW 8.0 kW 10.0 kW
Rated current maximum 12.5 A 17.3 A 18.5 A 23.5 A 27.5 A
Refrigerant R407C
Pmax. cooling circuit 24 bar (348 psi)
Temperature range Environment +10°C to +43°C (50°F to 109°F)
Liquid media +10°C to +30°C (50°F to 86°F)
Pump capacity See characteristic curve
Tank Made from PP plastic
Tank capacity in l (gal) 120 (31.7) 240 (63.4)
Water connections 3/4˝ IG 1˝ IG
Weight in kg (lb) 250 (551.2) 270 (595.2) 380 (837.8) 530 (1168.5) 560 (1234.6)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 6000 m3/h (3531 cfm) 8000 m3/h (4709 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +30°C (50°F to 86°F)
(factory setting +18°C (64°F))
Delivery times available on request.
Special voltages, other frequencies, and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
In industrial enclosure, cooling capacity 38 to 172 kW (131,245 to 587,411 BTU)
Chiller Systems
59Climate Control
B
4.1
Chiller Systems
T
H
B
B = Width
T = Depth
Technical design:
●Robust industrial enclosure
●Optimum service accessibil-
ity by removing the panels
●Floating contact for collective
fault signal
●With shell-and-tube evapora-
tor, without tank
(SK 3339.300 – .500)
●Integration of application-
specific equipment
on request
Configuration:
Chiller system wired and
plumbed ready for connection,
with multilingual documentation
including functional diagram
and wiring plans.
Note:
The illustration shows units with
customer-specific options.
Accessories:
Metal filter mat available on
request.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Characteristic curves of pump,
see page 132.
Options,
see page 126.
Part No. SK 3339.100 3339.200 3339.250 3339.280 3339.300 3339.400 3339.450 3339.500
Voltage V, Hz 400, 3~, 50/460, 3~, 60 400, 3~, 50
Dimensions in mm (inches)
H
B
T
1400 (55.1)
815 (32.1)
1560 (61.4)
1800 (70.9)
1000 (39.3)
2000 (78.7)
2000 (78.7)
1550 (61.0)
2500 (98.4)
2000 (78.7)
1550 (61.0)
3400 (133.9)
2200 (86.6)
1630 (64.2)
3400 (133.9)
Cooling capacity at
Tw = 10°C (50°F)/Tu = 32°C (90°F)
Tw = 18°C (64°F)/Tu = 32°C (90°F)
in W (BTU)
26150/31350
(89,307/
107,066)
32025/38430
(109,371/
131,245)
29550/35450
(100,919/
121,068)
36225/43480
(123,715/
148,492)
40000
(136,520)
46750
(159,557)
52000
(177,476)
59000
(201,367)
54700
(186,810)
66700
(227,792)
62200
(212,424)
75900
(259,212)
100000
(341,300)
110000
(375,430)
141000
(481,540)
172200
(588,094)
Power consumption 15900 W 17600 W 20600 W 36800 W 27000 W 28300 W 50000 W 61000 W
Rated current maximum 24.4 A 26.9 A 36,8 A 46,1 A 67 A 74 A 108 A 108 A
Refrigerant R407C
Pmax. cooling circuit 28 bar (406 psi)
Temperature range Environment +15°C to +45°C (59°F to +113°F)
Liquid media +10°C to +25°C (50°F to +77°F)
Pump capacity See characteristic curve
Tank Made from type 304 stainless steel
Tank capacity in l (gal) 150 (39.6) 220 (58.1) Pressure-sealed
Water connections 11/4˝ IG 11/2˝ IG 2˝ IG 3˝ IG
Weight in kg (lb) 280 (617.3) 300 (661.3)
680 (1499.1) 740 (7631.2)
800 (1763.7) 850 (1873.9) 950 (2094.4) 2100 (4629.7)
Color RAL 7035 (light gray)
Ratings (electric) IP 44
Air displacement of fans 18000 m3/h
(10,594 cfm)
32000 m3/h
(18,834 cfm)
40000 m3/h
(23,543 cfm)
48000 m3/h
(28,252 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to 77°F)
(factory setting +18°C (64°F))
Delivery times available on request.
Special voltages, other frequencies and refrigerants, and technical modifications available on request.
Air/water heat exchangers From page 68 By-pass safety valve Page 110 Additives Page 111
Immersible Chiller Systems
For oil, cooling capacity 2700 to 6300 W (9121/21,516 BTU)
60 Climate Control
B
4.1
Immersible Chiller Systems
T1
B1
H2
B2
T2
H1
B = Width
T = Depth
Technical design:
●For the cooling of oil
●Robust industrial standard in
3 enclosure sizes
●Flat evaporator coil resistant
to dirt
●Bi-frequency components
(50/60 Hz)
Configuration:
Immersible chiller system wired
and plumbed ready for connec-
tion, metal filter, eyebolts, with
multilingual documentation,
including functional diagram
and wiring plans.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Options,
see page 126.
Part No. SK for oil 3338.020 3338.040 3338.060 3338.080
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Cooling capacity at
Toil = 20°C (68°F)/
Tu = 32°C (90°F) in W (BTU) 2400/2700
(8196/9121) 3200/3600
(10,929/12,295) 4600/5200
(15,710/17,759) 5600/6300
(19,125/21,516)
Dimensions in mm (inches)
H1
B1
T1
1650 (65.0)
785 (31.0)
785 (31.0)
Dimensions of immersible part
in mm (inches)
B2
T2
719 (28.3)
719 (28.3)
Immersion depth in mm (inches) H2 550 (21.7)
Minimum medium level
with flat evaporator coil,
in mm (inches)
205 (8.1) 280 (11.0)
Power consumption 2.2 kW/2.7 kW 2.5 kW/3.1 kW 3.5 kW/4.3 kW 3.9 kW/4.7 kW
Rated current maximum 3.5 A/3.7 A 3.8 A/4.0 A 5.5 A/5.9 A 5.6 A/5.8 A
Refrigerant R134a
Pmax. cooling circuit 24 bar (348 psi)
Temperature range Environment +15°C to +42°C (59°F to 108°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Weight in kg (lb) 133 (293.2) 143 (315.3) 158 (348.3) 173 (381.4)
Color RAL 7035 (light gray)
Ratings (electric) IP 44
Air displacement of fans 1500/1560 m3/h (883/918 cfm) 2200/2350 m3/h (1295/1383 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +20°C (68°F))
Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
For oil, cooling capacity 9500 to 19400 W (32,444/66,254 BTU)
Immersible Chiller Systems
61Climate Control
B
4.1
Immersible Chiller Systems
T1
B1
H2
B2
T2
H1
B = Width
T = Depth
Technical design:
●For the cooling of oil
●Robust industrial standard in
3 enclosure sizes
●Flat evaporator coil resistant
to dirt
●Bi-frequency components
(50/60 Hz)
Configuration:
Immersible chiller system wired
and plumbed ready for connec-
tion, metal filter, eyebolts, with
multilingual documentation,
including functional diagram
and wiring plans.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Options,
see page 126.
Part No. SK for oil 3338.100 3338.120 3338.140 3338.160 3338.180 3338.200
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Cooling capacity at
Toil = 20°C (68°F)/Tu = 32°C (90°F)
in W (BTU) 8500/9500
(29,029/32,444) 10500/11800
(35,859/40,299) 12000/13400
(40,982/45,763) 13600/15200
(46,446/51,911) 15300/17100
(52,252/58,400) 17300/19400
(59,083/66,254)
Dimensions in mm (inches)
H1
B1
T1
1650 (65.0)
785 (30.9)
785 (30.9)
Dimensions of immersible
part in mm (inches)
B2
T2
719 (28.3)
719 (28.3)
Immersion depth
in mm (inches) H2 550 (21.7)
Minimum medium level
with flat evaporator coil,
in mm (inches)
330 (13.0) 380 (15.0) 430 (16.9)
Power consumption 6.2 kW/7.4 kW 6.8 kW/8.1 kW 7.6 kW/9.0 kW 8.4 kW/10.0 kW 9.3 kW/11.0 kW 10.4 kW/12.3 kW
Rated current maximum 8.4 A/8.6 A 9.2 A/9.3 A 10.1 A/10.5 A 11.1 A/11.5 A 12.1 A/12.4 A 13.3 A/13.7 A
Refrigerant R407C
Pmax. cooling circuit 27 bar (392 psi)
Temperature range Environment +15°C to +42°C (59°F to 108°F)
Liquid media +10°C to +25°C (50°F to +77°F)
Weight in kg (lb) 183 (403.4) 203 (447.5) 228 (502.7) 248 (546.7) 253 (557.8) 263 (579.8)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 7200/7480 m3/h (4238/4403 cfm) 7900/8480 m3/h (4650/4991 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +20°C (68°F))
Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Immersible Chiller Systems
For oil, cooling capacity 23200 to 87200 W (79,232/297,804 BTU)
62 Climate Control
B
4.1
Immersible Chiller Systems
T1
B1
H2
B2
T2
H1
B = Width
T = Depth
Technical design:
●For the cooling of oil
●Robust industrial standard in
3 enclosure sizes
●Flat evaporator coil resistant
to dirt
●Bi-frequency components
(50/60 Hz)
Configuration:
Immersible chiller system wired
and plumbed ready for connec-
tion, metal filter, eyebolts, with
multilingual documentation,
including functional diagram
and wiring plans.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Options,
see page 126.
Part No. SK for oil 3338.220 3338.240 3338.260 3338.280 3338.300 3338.320 3338.340 3338.360
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Cooling capacity at
Toil = 20°C (68°F)/Tu = 32°C
(90°F)
in W (BTU)
20700/23200
(70,694/
79,232)
30800/34500
(105,188/
117,824)
34900/39100
(119,190/
133,415)
44500/49800
(151,976/
170,076)
48600/54400
(165,978/
185,786)
60600/67900
(206,960/
231,891)
72600/81300
(247,942/
277,654)
77900/87200
(266,042/
297,804)
Dimensions
in mm (inches)
H1
B1
T1
1650 (65.0)
785 (30.9)
1830 (72.0)
1650 (65.0)
1830 (72.0)
1830 (72.0)
Dimensions
of immersible part
in mm (inches)
B2
T2
719 (28.3)
1764 (69.4)
1764 (69.4)
1764 (69.4)
Immersion depth
in mm (inches) H2 550 (21.7)
Minimum medium level
with flat evaporator coil,
in mm (inches)
380 (15.0) 430 (16.9) 380 (15.0) 430 (16.9)
Power consumption 12.9/16.1 kW 18.0 /22.0 kW 20.1 /24.8 kW 26.4 /31.4 kW 28.9/34.4 kW 34.4 /41.1 kW 39.9 /47.8 kW 42.5/50.9 kW
Rated current maximum 17.3 A/17.8 A 21.6 A/23.0 A 24.3 A/25.5 A 35.5 A/35.2 A 35.4 A/35.8 A 42.7 A/42.9 A 50.0 A/50.0 A 53.0 A/53.0 A
Refrigerant R407C
Pmax. cooling circuit 27 bar (392 psi)
Temperature range Environment +15°C to +45°C (59°F to 113°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Weight in kg (lb) 305 (672.4) 380 (837.8) 425 (937.0) 435 (959.0) 455 (1003.1)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 15000/15600 m3/h (8829/9182 cfm) 30000/31200 m3/h (17,657/18,364 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +20°C (68°F))
Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
For emulsion, cooling capacity 2700 to 6300 W (9221/21,515 BTU)
Immersible Chiller Systems
63Climate Control
B
4.1
Immersible Chiller Systems
T1
B1
H2
B2
T2
H1
B = Width
T = Depth
Technical design:
●For the cooling of emulsion
●Robust industrial standard in
3 enclosure sizes
●Flat evaporator coil resistant
to dirt
●Bi-frequency components
(50/60 Hz)
Configuration:
Immersible chiller system wired
and plumbed ready for connec-
tion, metal filter, eyebolts, with
multilingual documentation,
including functional diagram
and wiring plans.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Options,
see page 126.
Part No. SK for emulsion 3338.500 3338.520 3338.540 3338.560
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Cooling capacity at
Toil = 20°C (68°F)/Tu = 32°C (90°F)
in W (BTU) 2400/2700
(8196/9221) 3200/3600
(10,929/12,295) 4600/5200
(15,710/17,759) 5600/6300
(19,125/21,515)
Dimensions in mm (inches)
H1
B1
T1
1650 (65.0)
785 (30.9)
785 (30.9)
Dimensions of immersible part
in mm (inches)
B2
T2
719 (28.3)
719 (28.3)
Immersion depth
in mm (inches) H2 550 (21.7)
Minimum medium level
with flat evaporator coil,
in mm (inches)
180 (7.1) 205 (8.1)
Power consumption 2.4 kW/3.0 kW 2.7 kW/3.4 kW 3.7 kW/4.6 kW 4.1 kW/5.0 kW
Rated current maximum 3.8 A/4.0 A 4.1 A/4.3 A 5.9 A/6.3 A 6.0 A/6.3 A
Refrigerant R134a
Pmax. cooling circuit 24 bar (348 psi)
Temperature range Environment +15°C to +42°C (59°F to 108°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Weight in kg (lb) 130 (286.6) 140 (308.6) 155 (341.7) 170 (374.8)
Color RAL 7035 (light gray)
Ratings (electric) IP 44
Air displacement of fans 1500/1560 m3/h (883/918 cfm) 2200/2350 m3/h (1295/1384 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +20°C (68°F))
Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Immersible Chiller Systems
For emulsion, cooling capacity 9500 to 19400 W (32,445/66,254 BTU)
64 Climate Control
B
4.1
Immersible Chiller Systems
T1
B1
H2
B2
T2
H1
B = Width
T = Depth
Technical design:
●For the cooling of emulsion
●Robust industrial standard in
3 enclosure sizes
●Flat evaporator coil resistant
to dirt
●Bi-frequency components
(50/60 Hz)
Configuration:
Immersible chiller system wired
and plumbed ready for connec-
tion, metal filter, eyebolts, with
multilingual documentation,
including functional diagram
and wiring plans.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Options,
see page 126.
Part No. SK for emulsion 3338.580 3338.600 3338.620 3338.640 3338.660 3338.680
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Cooling capacity at
TEM = 20°C (68°F)/Tu = 32°C (90°F)
in W (BTU) 8500/9500
(29,029/32,444) 10500/11800
(35,859/40,299) 12000/13400
(40,982/45,763) 13600/15200
(46,446/51,911) 15300/17100
(52,252/58,400) 17300/19400
(59,083/66,254)
Dimensions in mm (inches)
H1
B1
T1
1650 (65.0)
785 (30.9)
785 (30.9)
Dimensions of immersible part
in mm (inches)
B2
T2
719 (28.3)
719 (28.3)
Immersion depth in mm (inches) H2 550 (21.7)
Minimum medium level
with flat evaporator coil, in mm (inches) 280 (11.0) 330 (13.0)
Power consumption 6.4/7.6 kW 7.0/8.3 kW 7.8/9.5 kW 8.6/10.2 kW 9.5/11.3 kW 10.6/12.6 kW
Rated current maximum 8.9 A/9.0 A 9.6 A/9.9 A 10.6 A/11.2 A 11.5 A/12.0 A 12.5 A/13.2 A 13.7 A/14.1 A
Refrigerant R407C
Pmax. cooling circuit 27 bar (392 psi)
Temperature range Environment +15°C to +42°C (59°F to 108°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Weight in kg (lb) 180 (396.8) 200 (440.9) 225 (496.0) 245 (540.1) 250 (551.2) 260 (573.2)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 7200/7480 m3/h (4238/4403 cfm) 7900/8480 m3/h (4650/4944 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +20°C (68°F))
Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
For emulsion, cooling capacity 23200 to 87200 W (79,232/297,804 BTU)
Immersible Chiller Systems
65Climate Control
B
4.1
Immersible Chiller Systems
T1
B1
H2
B2
T2
H1
B = Width
T = Depth
Technical design:
●For the cooling of emulsion
●Robust industrial standard in
3 enclosure sizes
●Flat evaporator coil resistant
to dirt
●Bi-frequency components
(50/60 Hz)
Configuration:
Immersible chiller system wired
and plumbed ready for connec-
tion, metal filter, eyebolts, with
multilingual documentation,
including functional diagram
and wiring plans.
Certifications,
available on the Internet,
log onto www.rittal-corp.com.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Layout diagram,
see page 132.
Options,
see page 126.
Part No. SK for emulsion 3338.700 3338.720 3338.740 3338.760 3338.780 3338.800 3338.820 3338.840
Voltage V, Hz 400, 3~, 50/460, 3~, 60
Cooling capacity at
TEM = 20°C (68°F)/Tu = 32°C (90°F)
in W (BTU)
20700/23200
(70,694/
79,232)
30800/34500
(108,186/
117,824)
34900/39100
(119,190/
133,534)
44500/49800
(151,976/
170,076)
48600/54400
(165,978/
185,786)
60600/67900
(206,960/
231,891)
72600/81300
(247,942/
277,654)
77900/87200
(266,042/
297,804)
Dimensions in mm (inches)
H1
B1
T1
1650 (65.0)
785 (462.0)
1830 (72.0)
1650 (65.0)
1830 (72.0)
1830 (72.0)
Dimensions of immersible
part in mm (inches)
B1
T2
719 (426.2)
1764 (1050.0)
1764 (1038.2)
1764 (1038.2)
Immersion depth
in mm (inches) H2 550 (323.7)
Minimum medium level
with flat evaporator coil, in mm
(inches)
280 (164.8) 330 (194.2) 280 (164.8) 330 (194.2) 380 (223.7)
Power consumption 13.3 kW/
16.6 kW
18.4 kW/
22.5 kW
20.5 kW/
25.3 kW
27.1 kW/
27.8 kW
29.7 kW/
35.4 kW
35.2 kW/
42.1 kW
40.7 kW/
48.8 kW
43.3 kW/
51.9 kW
Rated current maximum 17.9 A/
18.4 A
22.2 A/
23.6 A
24.9 A/
26.1 A
36.7 A/
36.5 A
36.6 A/
37.0 A
43.9 A/
44.1 A
51.2 A/
51.1 A
54.2 A/
54.2 A
Refrigerant R407C
Pmax. cooling circuit 27 bar (392 psi)
Temperature range Environment +15°C to +45°C (59°F to 113°F)
Liquid media +10°C to +25°C (50°F to 77°F)
Weight in kg (lb) 300 (661.8) 375 (826.7) 420 (925.9) 420 (925.9) 430 (948.0) 450 (992.1)
Color RAL 7035 (light gray)
Ratings (electric) IP 54 (NEMA 12)
Air displacement of fans 15000/15600 m3/h (8829/9182 cfm) 30000/31200 m3/h (17,657/18,364 cfm)
Temperature control Electronic control with digital display, setting range +10°C to +25°C (50°F to +77°F) (factory setting +20°C (68°F))
Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
66 Climate Control
Heat Exchangers
Features of air/air heat exchangers
B
4.1
Heat Exchangers
Platform concept/installation
Identical installation cutouts
for various output categories.
Easily retro-fitted
Due to the low weight, simple
assembly cutouts and problem-
free attachment of the heat
exchangers, a cabinet or
enclosure is easily retro-fitted.
Servicing/security
Simple maintenance
The heat exchanger module
removes easily for cleaning.
The cleverly designed structure
enables fast, economical
maintenance.
Benefits:
●Specific thermal output from
17.5 W/C to 90 W/C
●External and internal circuit
may be controlled separately
●Mounting cutouts and enclo-
sure dimensions identical to
TopTherm wall-mounted air
conditioners
●Suitable for external and
internal mounting
●Top design identical to
TopTherm wall-mounted air
conditioners
Important:
●The temperature difference
between the room tempera-
ture and enclosure internal
temperature will have a deci-
sive effect on the heat loss
that may be dissipated.
For calculation bases,
refer to our website:
www.rittal-corp.com
Rittal’s air/air heat exchangers are perfect for environments
where the ambient air temperature is at or below the desired
interior temperature of the enclosure. Two separate air cir-
cuits prevent dust and pollutants present in the ambient air to
ingress the enclosure interior.
The air of the enclosure interior may be cooled to below the
level of the external temperature by using air/water heat
exchangers with a central chiller system. Dust is unable to
penetrate the enclosure. The waste heat from the enclosure
does not raise the temperature of the ambient air, provided
the cold water supply system is spatially separated.
67Climate Control
Heat Exchangers
Features of air/water heat exchangers
B
4.1
Heat Exchangers
Even suitable for use in extreme conditions
1
4
3
3
2
Example: Parallel connection of
air/water heat exchangers with
cold water supplied by a chiller
system.
Versions
Roof-mount
Especially for bayed enclosures,
where wall-mounted devices
would obstruct the door.
Wall-mount
For mounting on the wall or any
sufficiently large vertical surface.
Sidewall
Economical use: Air/water heat
exchanger as a sidewall in the
TS8 modular enclosure system.
Controller
2
1
Benefits:
●Useful cooling capacity from
600 to 5000 W (2049 to
17,076 BTU)
●Suitable for use even in
extreme conditions and
ambient temperatures up to
+70°C (158°F)
●Also available with all water-
carrying parts made from
type 316 stainless steel (V4A)
●System for TS8 modular
enclosure system integrated
into the sidewall
Important:
●Air/water heat exchangers
should always be used in
conjunction with chiller
systems or a cooling water
circuit
For calculation formulas
and requirements
regarding water quality,
refer to our website:
www.rittal-corp.com
Overflow valves and bypass
controls should be integrated
into the chiller system and the
customer’s own pipeline system
respectively.
Chiller system
Air/water heat exchanger,
roof-mounted
Air/water heat exchanger,
wall-mounted
Additional cooling water
circuit for machine cooling
Ideal for any location
If direct dissipation of heat loss
to the ambient air is not desired
or ineffective due to confined
spaces, the air/water heat
exchangers will provide the
ideal solution. By spatially sepa-
rating the exchanger from the
chiller system, highly individual
and effective solutions for cool-
ing individual enclosures or
bayed enclosure suites can be
achieved.
1
2
3
4
Basic controller:
●Visualisation of the operating
status by a LED display
●Switching hysteresis: 5 K
●Floating fault signal contact in
case of over temperature
●Setpoint adjustable from the
outside by a potentiometer
(setting range 20° – 55°C
(68° – 131°F))
Comfort controller
●Switching hysteresis: 2 – 10 K
preset to 5 K
●System alarm, individually
configurable for 2 floating fault
signal contacts
●Visualisation of the current
enclosure internal tempera-
ture and all system messages
on the display
●Storage of all system states in
the log file
●Optional extension card for
integration into superordinate
remote monitoring systems
such as CMC
Flexible water logistics and
condensate management
Any condensate is discharged
by one of the two tube connec-
tors (1/2˝) and a discharge hose,
which should be laid with a gra-
dient to ensure that there are no
kinks. In order to avoid
increased condensation, the
cooling water temperature
should be adapted to match the
required cooling capacity.
Condensate discharge
(flexible)
Cooling water connection
(flexible)
1
2
Air/Water Heat Exchanger
Micro, wall-mounted, useful cooling capacity 300 W (1025 BTU)
68 Climate Control
B
4.1
Air/Water Heat Exchanger
85
300
150
1
2
85
300
150
1
2
Especially for selective cooling
of heat pockets in small enclo-
sures.
Configuration:
Fully wired ready for connec-
tion, including drilling template
and assembly parts.
Condensate discharge
Cooling water connection
(quick-release fastener)
Certifications,
see page 16.
Detailed drawing,
see page 133.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
1
2
Part No. SK 3212.230 3212.1151) 3212.024
Voltage V, Hz 230, 50/60 115, 50/60 24 V (DC)
Dimensions in mm (inches)
H
W
D
300 (11.8)
150 (5.9)
85 (3.3)
Useful cooling capacity
in W (BTU) L 35 W 10
200 l/h (52.8 gal/h) 300 (1025)
Rated current maximum 0.11 A/0.13 A 0.23 A/0.24 A 1.20 A
Pre-fuse T 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 12)
Water inlet temperature > +1°C to +30°C (34°F to 86°F)
Permissible operating pressure p. max. 1 to 10 bar (15 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 55 (NEMA 3R)2)
Duty cycle 100 %
Type of connection Connection clamp
Weight in kg (lb) 3 (6.6)
Color RAL 7035 (light gray)
Air displacement of fans (unimpeded air flow) 280 m3/h (165 cfm) 250 m3/h (147 cfm)
Accessories PU Page
Temperature indicator 1 3114.100 103
Door-operated switch 1 4127.000 –
Condensate hose 1 3301.612 108
Flow regulator valve 1 see accessories 110
1) Delivery times available on request.
2) IP 65 (NEMA 4X) available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100 Chiller systems From page 44
Wall-mounting, useful cooling capacity 600/1000 W (2049/3415 BTU)
Air/Water Heat Exchanger
69Climate Control
B
4.1
Air/Water Heat Exchanger
100
500
200
135
520
298
1
21
2
Configuration:
Fully wired ready for connection
with terminal strip, including
drilling template, sealing mat
and assembly parts.
Also required:
Cooling water system such as
Rittal chiller systems,
from page 50.
Condensate discharge 1/2˝
Cooling water connection 1/2˝
Certifications,
see page 17.
Detailed drawing,
see page 133.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
1
2
Part No. SK 3214.100 3217.100
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
W
D
500 (19.7)
200 (7.9)
100 (3.9)
520 (20.5)
298 (11.7)
135 (5.3)
Useful cooling capacity
in W (BTU) L 35 W 10, 200 l /h (52.8 gal/h)
L 35 W 10, 400 l/h (105 gal/h) 600 (2049)
650 (2220) 1000 (3415)
1100 (3757)
Rated current maximum 0.17 A/0.18 A 0.6 A/0.55 A
Pre-fuse T 2.0 A 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 12)
Water inlet temperature > +1°C to +30°C (34°F to 86°F)
Permissible operating pressure p. max. 1 to 10 bar (14.5 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 55 (NEMA 3R)1)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lb) 7 (15.4) 9.5 (20.9)
Color RAL 7032 (pepple gray)
Air displacement of fans 120 m3/h (71 cfm) 240 m3/h (141 cfm)
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring Internal thermostat, with change-over contact, switching load 16 A,
setting range +20°C to +60°C (68°F to 140°F)(factory setting +35°C (95°F))
Accessories PU Page
Temperature indicator 1 3114.100 103
Door-operated switch 1 4127.000 –
Condensate hose 1 3301.612 108
Flow regulator valve 1 see accessories 110
1) IP 65 (NEMA 4X) available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100 Chiller systems From page 44
Air/Water Heat Exchanger
Wall-mounting, useful cooling capacity 1250/1540 W (4869/5259 BTU)
70 Climate Control
B
4.1
Air/Water Heat Exchanger
100
950
200
1
2
825
380
105
1
2
Configuration:
Fully wired ready for connection
with terminal strip or connection
cable (3 m (118˝)), including
drilling template, sealing mat
and assembly parts.
Also required:
Cooling water system such as
Rittal chiller systems,
from page 50.
Condensate discharge 1/2˝
Cooling water connection 1/2˝
Certifications,
see page 17.
Detailed drawing,
see page 134.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
1
2
Part No. SK 3215.100 3247.000
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
W
D
950 (37.4)
200 (7.9)
100 (3.9)
825 (32.5)
380 (15.0)
105 (4.1)
Useful cooling capacity
in W (BTU) L 35 W 10, 200 l/h (52.8 gal/h)
L 35 W 10, 400 l/h (105 gal/h) 1250 (4269)
1300 (4440) 1540 (5259)
1700 (5806 )
Rated current maximum 0.38 A/0.4 A 0.43 A/0.5 A
Pre-fuse T 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 12)
Water inlet temperature > +1°C to +30°C (34°F to 86°F)
Permissible operating pressure p. max. 1 to 10 bar (14.5 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 55 (NEMA 3R)1)
Duty cycle 100 %
Type of connection Terminal strip Connection cable 3 m (118˝)
Weight in kg (lb) 13 (28.7) 17 (37.5)
Color RAL 7032 (pepple gray)
Air displacement of fans 200 m3/h (118 cfm) 240 m3/h (141 cfm)
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring Internal thermostat, with change-over contact, switching load 16 A,
setting range +20°C to +60°C (68°F to 140°F) (factory setting +35°C (95°F))
Accessories PU Page
Temperature indicator 1 3114.100 103
Door-operated switch 1 4127.000 –
Condensate hose 1 3301.612 108
Flow regulator valve 1 see accessories 110
1) IP 65 (NEMA 4X) available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100 Chiller systems From page 44
Wall-mounted, useful cooling capacity 2250/3000/4500/7000 W(7684/10,246/15,368/23,885 BTU)
Air/Water Heat Exchanger
71Climate Control
B
4.1
Air/Water Heat Exchanger
200
950
400
250
1400
450
1
2
1
2
Configuration:
Fully wired ready for connection
with terminal strip, including
drilling template, sealing mat
and assembly parts.
Also required:
Cooling water system such as
Rittal chiller systems,
from page 50.
Condensate discharge 1/2˝
Cooling water connection 1/2˝
Certifications,
see page 17.
Detailed drawing,
see page 134.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
1
2
Part No. SK 3218.1041) 3218.100 3216.100 3216.480
Voltage V, Hz 230, 50/60 400, 3~, 50/60
480, 3~, 60
Dimensions in mm (inches)
H
W
D
950 (37.4)
400 (15.7)
200 (7.9)
1400 (55.1)
450 (17.7)
250 (9.8)
1800 (70.9)
450 (17.7)
300 (11.8)
Useful cooling capacity
in W (BTU) L 35 W 10, 200 l/h (52.8 gal/h)
L 35 W 10, 400 l/h (105 gal/h) 2250 (7684)
2650 (9050) 3000 (10,246)
3500 (11,953) 4500 (15,368)
5000 (17,076) 7000 (23,885)
4500 (15,368)
Rated current maximum 0.42 A/0.48 A 1.0 A/1.1 A 1,4 A/1,6 A
1,2 A
Pre-fuse T 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 12)
Water inlet temperature > +1°C to +30°C (34°F to 86°F)
Permissible operating pressure p. max. 1 to 10 bar (14.5 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 55 (NEMA 3R)2)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lb) 19 (41.9) 21 (46.3) 56 (123.5) 79 (174.2)
Color RAL 7032 (pepple gray)
Air displacement of fans 240 m3/h (141 cfm) 450 m3/h (265 cfm) 1000 m3/h (589 cfm) 2400 m3/h (4078 cfm)
Temperature control Thermostat-controlled magnetic valve
Accessories PU Page
Temperature indicator 1 3114.100 103
Door-operated switch 1 4127.000 –
Condensate hose 1 3301.612 108
Flow regulator valve 1 see accessories 110
1) Delivery times available on request, all water-carrying parts V4A 1.4571 (type 316 stainless steel).
2) IP 65 (NEMA 4X) available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100 Chiller systems From page 44
Air/Water Heat Exchanger
Roof-mounted, useful cooling capacity 2500 W (8538 BTU)
72 Climate Control
B
4.1
Air/Water Heat Exchanger
2
1
475
597
415
390
490
Configuration:
Fully wired ready for connection
with connector, including drilling
template, sealing mat and
assembly parts.
Also required:
Cooling water system such
as Rittal chiller systems,
from page 50.
Condensate discharge
(flexible)
Cooling water connection
(flexible)
Certifications,
see page 17.
Detailed drawing,
see page 135.
Performance diagrams,
available on the Internet
log onto www.rittal-corp.com.
Property rights:
German registered designs
no. 402 02 324 and
no. 402 02 325
US design patent
no. US D 492,319S
Indian registered design
no. 189 956
Chinese registered design
no. ZL 0330 6415.6
1
2
Water-carrying parts
Part No. SK basic controller CuAL 3209.100 3209.110 3209.1401)
Part No. SK comfort controller CuAL 3209.500 3209.510 3209.5401)
Useful cooling capacity CuAL
in W (BTU) L 35 W 10,
400 l/h (105 gal/h) 2500 (8538)
Part No. SK basic controller V4A
(type 316 stainless steel) 3209.1041) 3209.1141) 3209.1441)
Part No. SK comfort controller 3209.5041) 3209.5141) 3209.5441)
Useful cooling capacity V4A
in W (BTU) L 35 W 10,
400 l/h (105 gal/h) 1875 (6403)
Voltage V, Hz 230, 50/60 115, 50/60 400, 2~, 50/60
Dimensions in mm (inches)
H
W
D
415 (16.3)
597 (23.5)
475 (18.7)
Rated current maximum 0.40 A 0.85 A 0.25 A
Pre-fuse T 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 13)
Water inlet temperature > +1°C to +30°C (34°F to 86°F)
Permissible operating pressure p. max. 1 to 10 bar (14.5 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 55 (NEMA 3R)2)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 23.5 (51.8) 27.5 (60.6) 27.5 (60.6)
Color RAL 7035 (light gray)
Air displacement of fans (unimpeded air flow) 1030 m3/h (606 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
Interface card for comfort controller 1 3124.200 105
Air ducting system 1 3286.870 101
Cover stoppers for interior air outlet 1 3286.880 101
Condensate hose 1 3301.612 108
Flow regulator valve 1 see accessories 110
1) Delivery times available on request.
2) IP 65 (NEMA 4X) available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100 Chiller systems From page 44
Roof-mounted, useful cooling capacity 4000 W (13,661 BTU)
Air/Water Heat Exchanger
73Climate Control
B
4.1
Air/Water Heat Exchanger
Accessories Page 100 Chiller systems From page 44
2
1
475
597
415
390
490
Configuration:
Fully wired ready for connection
with connector, including drilling
template, sealing mat and
assembly parts.
Also required:
Cooling water system such
as Rittal chiller systems,
from page 50.
Condensate discharge
(flexible)
Cooling water connection
(flexible)
Certifications,
see page 17.
Detailed drawing,
see page 135.
Performance diagrams,
available on the Internet,
log onto www.rittal-cop.com.
Property rights:
German registered designs
no. 402 02 324 and
no. 402 02 325
US design patent
no. US D 492,319S
Indian registered design
no. 189 956
Chinese registered design
no. ZL 0330 6415.6
1
2
Water-carrying parts
Part No. SK basic controller CuAL 3210.100 3210.110 3210.1401)
Part No. SK comfort controller CuAL 3210.500 3210.510 3210.5401)
Useful cooling capacity CuAL
in W (BTU) L 35 W 10,
400 l/h (105 gal/h) 4000 (13,661)
Part No. SK basic controller V4A
(type 316 stainless steel) 3210.1041) 3210.1141) 3210.1441)
Part No. SK comfort controller 3210.5041) 3210.5141) 3210.5441)
Useful cooling capacity V4A
in W (BTU) L 35 W 10,
400 l/h (105 gal/h) 3000 (10,246)
Voltage V, Hz 230, 50/60 115, 50/60 400, 2~, 50/60
Dimensions in mm (inches)
H
W
D
415 (16.3)
597 (23.5)
475 (18.7)
Rated current maximum 0.44 A 0.9 A 0.25 A
Pre-fuse T 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 13)
Water inlet temperature >+1°C to +30°C (34°F to 86°F)
Permissible operating pressure p. max. 1 to 10 bar (14.5 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 55 (NEMA 3R)2)
Duty cycle 100 %
Type of connection Plug-in terminal strip
Weight in kg (lb) 25.5 (56.2) 29.5 (65.0) 29.5 (65.0)
Color RAL 7035 (light gray)
Air displacement of fans (unimpeded air flow) 925 m3/h (544 cfm)
Temperature control Basic or comfort controller (factory setting +35°C (95°F))
Accessories PU Page
Door-operated switch 1 4127.000 –
SK bus system for comfort controller 1 3124.100 106
Interface card for comfort controller 1 3124.200 105
Air ducting system 1 3286.870 101
Cover stoppers for interior air outlet 1 3286.880 101
Condensate hose 1 3301.612 108
Flow regulator valve 1 see accessories 110
1) Delivery times available on request.
2) IP 65 (NEMA 4X) available on request.
Special voltages available on request. We reserve the right to make technical modifications.
Air/Water Heat Exchanger
Sidewall for 600 mm (23.6˝) deep TS8 modular enclosure, useful cooling capacity 700 W (2391 BTU)
74 Climate Control
B
4.1
Air/Water Heat Exchanger
T
H
1190
1
2
3
2T = Depth
Configuration:
Wired ready for connection, with
terminal strip, sealing material
and assembly parts.
Also required:
Cooling water system such as
Rittal chiller systems,
from page 50.
Water connections
Hose 10 mm (0.4˝) diameter
Condensate discharge
Certifications,
see page 17.
Detailed drawing,
see page 135.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Property rights:
German patent
no. 198 04 901
European patent no. 1 053 582
with validity for ES, FR, GR, IT
Australian patent no. 740 300
US patent no. 6,488,214
1
2
3
Part No. SK 3316.180 3316.200
Voltage V, Hz 230, 50/60
Dimensions
to fit TS modular enclosures in mm (inches)
H
T
1800 (70.9)
600 (23.6)
2000 (78.7)
600 (23.6)
Useful cooling capacity
in W (BTU) L 35 W 10,
100 l/h (26.4 gal/h) 700 (2391)
Rated current maximum 0.45 A/0.51 A
Pre-fuse T 4.0 A
Cooling medium Water (refer to specifications on the Internet; assembly instructions chapter 12)
Water inlet temperature >+1°C to +35°C (34°F to 95°F)
Permissible operating pressure p. max. 1 to 10 bar (14.5 to 145 psi)
Temperature range +1°C to +70°C (34°F to 158°F)
Ratings to EN 60 529/10.91 IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Terminal strip
Weight in kg (lb) 26 (57.3)
Color RAL 7035 (light gray)1)
Air displacement of fans 170 m3/h (100 cfm)
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring Internal thermostat, with change-over contact, switching load 16 A,
setting range +20°C to +60°C (68°F to 140°F) (factory setting +35°C (95°F))
Accessories PU Page
Temperature indicator 1 3114.100 103
Door-operated switch 1 4127.000 –
Condensate hose 1 3301.610 108
Flow regulator valve 1 see accessories 110
1) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100 Chiller systems From page 44
Wall-mounted, specific thermal output 17.5 – 60 W/C
Air/Air Heat Exchangers
75Climate Control
B
4.1
Air/Air Heat Exchangers
108
42
550
150
280
T2
50
950
T1
400
Configuration:
Fully wired unit ready for
connection.
Certifications,
see page 18.
Detailed drawing,
see page 136.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Property rights:
German registered designs
no. 402 02 324 and
no. 402 02 325
IR reg. design no. DM/061 967
and no. DM/062 557
Chinese registered design
no. ZL 0330 8461.1
Indian registered design
no. 190 269 and no. 189 953
Japanese registered design
no. 1 187 905 and
no. 1 187 896
US design patent
no. US D 488,480S
Part No. SK 3126.100 3127.100 3128.100 3129.100
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
B
T1
T2
550 (21.7)
280 (11.0)
150 (5.9)
–
950 (37.4)
400 (15.7)
205 (8.1)
155 (6.1)
950 (37.4)
400 (15.7)
225 (8.9)
175 (6.9)
Specific thermal output 17.5 W/C 30 W/C 45 W/C 60 W/C
Fans 2 per heat exchanger
Maximum rated current per fan 0.11 A/0.13 A 0.28 A/0.34 A 0.3 A/0.4 A 0.38 A/0.4 A
Power per fan 23 W/27 W 60 W/75 W 70 W/90 W 85 W/90 W
Air displacement of fans External circuit 265/315 m3/h
(156/185 cfm)
480/525 m3/h
(283/309 cfm)
600/625 m3/h
(353/368 cfm)
860/900 m3/h
(506/530 cfm)
Internal circuit
Temperature range –5°C to +55°C (23°F to 131°F)
Type of connection Plug-in terminal strip
Weight in kg (lb) 10 (22.0) 18 (40.0) 19 (41.9) 21 (46.3)
Color RAL 7035 (light gray)
Ratings to EN 60 529/10.91 Internal circuit IP 54 (NEMA 12)
Accessories PU Page
Filter mats 3 3286.300 3286.400 111
Metal filters 1 3286.310 3286.410 112
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 103
Speed control 1 3120.000 105
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100
B = Width
T = Depth
Air/Air Heat Exchangers
Wall-mounted, specific thermal output 90 W/C
76 Climate Control
B
4.1
Air/Air Heat Exchangers
1580
215
400
165
50
Configuration:
Fully wired unit ready for
connection.
Certifications,
see page 18.
Detailed drawing,
see page 136.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Property rights:
German registered designs
no. 402 02 324 and
no. 402 02 325
IR reg. design no. DM/061 967
and no. DM/062 557
Brazilian registered design
no. DI 6203240-2
Chinese registered design
no. ZL 0330 4386.8
Indian registered designs
nos. 190 270, 189 954, 189 955,
189 958
Japanese registered design
no. 1 187 906 and no. 1 187 897
US design patent
no. US D 492,319S and
US D 492,320S
Accessories Page 100
Part No. SK 3130.100
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
W
D
1580 (62.2)
400 (15.7)
215 (8.5)
Specific thermal output 90 W/C
Fans 2 per heat exchanger
Maximum rated current per fan 0.67 A/0.88 A
Power per fan 150 W/200 W
Air displacement of fans External circuit 850/945 m3/h (500/556 cfm)
Internal circuit 850/945 m3/h (500/556 cfm)
Temperature range –5°C to +55°C (23°F to 131°F)
Type of connection Plug-in terminal strip
Weight in kg (lb) 34 (75.0)
Color RAL 7035 (light gray)
Ratings to EN 60 529/10.91 Internal circuit IP 54 (NEMA 12)
Accessories PU Page
Filter mats 3 3286.400 111
Metal filters 1 3286.410 112
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 103
Speed control 1 3120.000 105
Special voltages available on request. We reserve the right to make technical modifications.
Wall-mounted
Air/Air Heat Exchangers
77Climate Control
B
4.1
Air/Air Heat Exchangers
T
H
B
B
H
T
T
H
B
B
H
T
B = Width
H = Depth
Configuration:
Fully wired unit, ready for
connection.
Certifications,
see page 18.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
SK 3125.800
Compact, wall-mounted air/air
heat exchanger. Ideal for small
and operator housings.
May be wall-mounted, recessed
or partially recessed.
SK 3129.800
Ultra slim air/air heat exchanger.
Ideal for mounting on or in the
door of an enclosure.
Part No. SK 3125.800 3129.800
Voltage Volt, Hz 230, 50/60
Dimensions in mm (inches)
H
B
T
400 (15.7)
200 (7.9)
146 (5.7)
1360 (53.5)
400 (15.7)
110 (4.3)
Specific thermal output 12 W/C 62 W/C
Fans 2 each per heat exchanger
Maximum rated current per fan 0.11 A/0.13 A 0.45 A/0.55 A
Power per fan 25 W/30 W 100 W/130 W
Air displacement per fan External circuit 265 m3/h/315 m3/h (156/185 cfm) 360 m3/h/900 m3/h (212/530 cfm)
Internal circuit 265 m3/h/315 m3/h (156/185 cfm) 360 m3/h/900 m3/h (212/530 cfm)
Temperature range –5°C up to +55°C (23°F to 131°F)
Type of connection Plug-in terminal strip
Weight in kg (lb) 8 (17.6) 30 (66.1)
Color RAL 7035 (light gray)
Ratings to EN 60 529/10.91 Internal circuit IP 54 (NEMA 12)
Accessories PU Page
Thermostat 1 ea 3110.000 104
Temperature indicator 1 ea 3114.100 103
Speed control 1 ea 3120.000 105
Special voltages upon request. We reserve the right to technical modifications.
Accessories Page 100
78 Climate Control
Filter Fan Units
Features
B
4.1
Filter Fan Units
Filter fan units are ideal for cost effectively dissipating high
heat loads. The prerequisite is that the ambient air must be
relatively clean with a temperature below the desired enclo-
sure internal temperature.
The entire range of filter fan units is now available with EMC
shielding and all required rated voltages.
Fast assembly
Quick clip-on mounting
This guarantees quick, completely
secure attachment of the filter fan
unit. The prerequisites for ratings
IP 54 (NEMA 12) are met as stan-
dard.
Changing the filter mat is quick
and easy. The louvered grille is
attached without screws provid-
ing quick access to the filter
mat.
Inlet or outlet
The air direction may be quickly
reversed from blowing (stan-
dard setting) to extracting.
Simply rotate the fan by 180°.
Application diversity and functions
Not always full power
Air displacement may be re-
duced at lower ambient temper-
atures. Noise generation is
reduced by adapting the filter
fan speed to match the tempera-
ture using a controller.
Also available with EMC
shielding
All filter fan units and outlet fil-
ters are available with EMC
shielding. The required conduc-
tive connection is achieved by a
metallic coating on the filter fan
unit housing and a special seal-
ing frame.
Hosed water protection
Particularly for applications in
the food industry, the hose-proof
hood prevents the ingress of
moisture. The ratings of IP 56
(NEMA 3R) is achieved in con-
junction with the filter mats.
Benefits:
●Air displacement of 20 m3/h
to 700 m3/h (12 to 412 cfm)
●Quick assembly
●IP 54 (NEMA 12) as standard
●Air flow direction may be
reversed from blowing
(standard setting) to
extracting
●All fans are also available
with EMC shielding
Important:
●The prescribed heat loss and
the maximum anticipated
ambient temperature define
the required volumetric flow
●Always use the filter fan units
and outlet filters together
For calculation formulas
refer to our website:
www.rittal-corp.com
Air displacement 12/39 cfm
Filter Fan Units
79Climate Control
B
4.1
Filter Fan Units
H2
B2
T2
B1
T1
H1
B = Width
T = Depth
Configuration:
Filter fan unit ready for installa-
tion, including filter mats.
German registered design
no. M 93 04 846 Certifications,
see page 18.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. filter fan unit SK 3321.107 3321.117 3321.027 3321.0471) 3322.107 3322.117 3322.027 3322.0471)
Voltage V, Hz 230, 50/60 115, 50/60 24 (DC) 48 (DC) 230, 50/60 115, 50/60 24 (DC) 48 (DC)
Dimensions in mm (inches)
H1/B1 116 (4.6) 148 (5.8)
H2/B2 92 + 0.8 (3.6 + 0.03)2) 124 (4.9)2)
T1 10 (0.4) 10 (0.5)
Max. installation depth
in mm (inches) T2 42 (1.7) 57 (2.2)
Air displacement, unimpeded air flow 20/25 m3/h (12/15 cfm) 20 m3/h (12 cfm) 55/66 m3/h (32/39 cfm) 55 m3/h (32 cfm)
Air displacement with outlet filter
including standard filter mat 1 x SK 3321.207: 15/18 m3/h (9/11 cfm) 1 x SK 3322.207: 43/50 m3/h (25/29 cfm)
Axial fan self-starting shaded
pole motor DC motor self-starting shaded
pole motor DC motor
Rated current maximum 69 mA
58 mA
138 mA
115 mA 125 mA 90 mA 0.12 A
0.11 A
0.24 A
0.23 A 0.35 A 90 mA
Power 12.5/10.3 W 3.0 W 4.1 W 19.0/18.0 W 7.7 W 4.4 W
Noise level 41/46 dB (A) 41 dB (A) 46/49 dB (A) 46 dB (A)
Temperature range –10°C to +55°C (13°F to 131°F)
Color RAL 7035 (light gray)3)
Ratings to EN 60 529/10.91 IP 54 (NEMA 12) standard
IP 56 (NEMA 3R) when using a hose-proof hood
Part No. outlet filter SK 3321.207 3322.207
Accessories PU Page
Spare filter mats 5 3321.700 3322.700 113
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 3114.115 3114.024 – 3114.100 3114.115 3114.024 – 103
Speed control 1 3120.000 3120.115 – – 3120.000 3120.115 – – 105
Hose-proof hood 1 3321.800 3322.800 109
1) Delivery times available on request.
2) For metal thickness > 2.5 mm (0.1˝), the cutout H2/B2 (W) must be 1 mm (0.04˝) larger
3) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
Filter Fan Units
Air displacement 62/106 cfm
80 Climate Control
B
4.1
Filter Fan Units
H2
B2
T2
B1
T1
H1
B = Width
T = Depth
Configuration:
Filter fan unit ready for installa-
tion, including filter mats.
German registered design
no. M 93 04 846 Certifications,
see page 18.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. filter fan unit SK 3323.107 3323.117 3323.027 3323.0471) 3324.107 3324.117 3324.027 3324.0471)
Voltage V, Hz 230, 50/60 115, 50/60 24 (DC) 48 (DC) 230, 50/60 115, 50/60 24 (DC) 48 (DC)
Dimensions in mm (inches)
H1/B1 204 (8.0) 255 (10.0)
H2/B2 177 (7.0)2) 224 (8.8)2)
T1 12 (0.5) 12 (0.5)
Maximum installation depth
in mm (inches) T2 82 (3.2) 105 (4.2)
Air displacement, unimpeded air flow 105/120 m3/h (62/71 cfm) 105 m3/h (62 cfm) 180/160 m3/h (106/94 cfm) 180 m3/h (106 cfm)
Air displacement with outlet filter
including standard filter mat
1 x SK 3323.207: 71/82 m3/h (42/48 cfm)
2 x SK 3323.207: 85/98 m3/h (50/58 cfm)
1 x SK 3325.207: 78/90 m3/h (46/53 cfm)
1 x SK 3325.207: 115/95 m3/h (68/56 cfm)
2 x SK 3325.207: 165/140 m3/h (97/82 cfm)
1 x SK 3326.207: 155/130 m3/h (91/78 cfm)
Axial fan self-starting
shaded pole motor DC motor self-starting
shaded pole motor DC motor
Rated current maximum 0.12 A
0.11 A
0.24 A
0.23 A 0.35 A 90 mA 0.19 A
0.20 A
0.38 A
0.40 A 0.3 A 0.34 A
Power 19.0 W/18.0 W 8.0 W 4.3 W 30.0 W/35.0 W 7.2 W 14.0 W
Noise level 46/49 dB (A) 46 dB (A) 52/48 dB (A) 52 dB (A)
Temperature range –10°C to +55°C (13°F to 131°F)
Color RAL 7035 (light gray)3)
Ratings to EN 60 529/10.91
IP 54 (NEMA 12) standard
IP 55
IP 56 (NEMA 3R) when using an additional fine filter mat and hose-proof hood
Part No. outlet filter SK 3323.207 3325.207
Accessories PU Page
Spare filter mats 5 3171.100 3172.100 113
Fine filter mats 5 3181.100 3182.100 113
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 3114.115 3114.024 – 3114.100 3114.115 3114.024 – 103
Speed control 1 3120.000 3120.115 – – 3120.000 3120.115 – – 105
Hose-proof hood 1 3323.800 3324.800 109
1) Delivery times available on request.
2) For metal thickness > 2.5 mm (0.1˝), the cutout H2/B2 (W) must be 1 mm (0.04˝) larger.
3) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
Air displacement 135/156 cfm
Filter Fan Units
81Climate Control
B
4.1
Filter Fan Units
H2
B2
T2
B1
T1
H1
B = Width
T = Depth
Configuration:
Filter fan unit ready for installa-
tion, including filter mats.
German registered design
no. M 93 04 846 Certifications,
see page 18.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. filter fan unit SK 3325.107 3325.117 3325.027 3325.0471)
Voltage V, Hz 230, 50/60 115, 50/60 24 (DC) 48 (DC)
Dimensions in mm (inches)
H1/B1 255 (10.0)
H2/B2 224 (8.8)2)
T1 12 (0.5)
Max. installation depth
in mm (inches) T2 105 (4.2)
Air displacement, unimpeded air flow 230/265 m3/h (135/156 cfm) 230 m3/h (135 cfm)
Air displacement with outlet filter
including standard filter mat
1 x SK 3325.207: 170/205 m3/h (100/121 cfm)
2 x SK 3325.207: 200/230 m3/h (118/135 cfm)
1 x SK 3326.207: 190/215 m3/h (112/127 cfm)
Axial fan self-starting shaded pole motor DC motor
Rated current maximum 0.28 A
0.24 A
0.53 A
0.49 A 0.59 A 0.31 A
Power 41.0/38.0 W 14.0 W 15.0 W
Noise level 54/56 dB (A) 54 dB (A)
Temperature range –10°C to +55°C (13°F to 131°F)
Color RAL 7035 (light gray)3)
Ratings to EN 60 529/10.91
IP 54 (NEMA 12) standard
IP 55
IP 56 (NEMA 3R) when using an additional fine filter mat and hose-proof hood
Part No. outlet filter SK 3325.207
Accessories PU Page
Spare filter mats 5 3172.100 113
Fine filter mats 5 3182.100 113
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 3114.115 3114.024 – 103
Speed control 1 3120.000 3120.115 – – 105
Hose-proof hood 1 3324.800 109
1) Delivery times available on request.
2) For metal thickness > 2.5 mm (0.1˝), the cutout H2/B2 (W) must be 1 mm (0.04˝) larger.
3) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
Filter Fan Units
Air displacement 353/424 cfm
82 Climate Control
B
4.1
Filter Fan Units
H2
B2
T2
B1
T1
H1
B = Width
T = Depth
Configuration:
Filter fan unit ready for
installation, including filter mats.
German registered design
no. M 93 04 846 Certifications,
see page 18.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. filter fan unit SK 3326.107 3326.117 3327.107 3327.117 3327.147
Voltage V, Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60 400/460, 3~, 50/60
Dimensions in mm (inches)
H1/B1 323 (12.7)
H2/B2 292 (11.5)1)
T1 12 (0.5)
Maximum installation depth
in mm (inches) T2 125 (4.9) 145 (5.7)
Air displacement, unimpeded air flow 550/600 m3/h (323/353 cfm) 700/720 m3/h (412/424 cfm)
Air displacement with outlet filter
including standard filter mat
1 x SK 3326.207: 360/390 m3/h (212/230 cfm)
2 x SK 3326.207: 440/495 m3/h (259/291 cfm) 1 x SK 3326.207: 525/575 m3/h (309/338 cfm)
Axial fan Capacitor motor Rotary current motor
Rated current maximum 0.29 A
0.35 A
0.58 A
0.70 A
0.65 A
0.95 A
1.5 A
2.0 A
0.27 A
0.37 A
Power 64.0/80.0 W 115.0/212.0 W 167.0/230.0 W 146.0/220.0 W
Noise level 59/61 dB (A) 75/76 dB (A)
Temperature range –10°C to +55°C (13°F to 131°F)
Color RAL 7035 (light gray)2)
Ratings to EN 60 529/10.91
IP 54 (NEMA 12) standard
IP 55
IP 56 (NEMA 3R) when using an additional fine filter mat and hose-proof hood
Part No. outlet filter SK 3326.207
Accessories PU Page
Spare filter mats 5 3173.100 3327.700 113
Fine filter mats 5 3183.100 113
Thermostat 1 3110.000 – 104
Temperature indicator 1 3114.100 3114.115 3114.100 3114.115 – 103
Speed control 1 3120.000 3120.115 3120.000 – – 105
Hose-proof hood 1 3326.800 109
1) For metal thickness > 2.5 mm (0.1˝), the cutout H2/B2 (W) must be 1 mm (0.04˝) larger.
2) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
Air displacement 12/71 cfm
Filter Fan Unit – EMC
83Climate Control
B
4.1
Filter Fan Unit – EMC
H2
B2
T2
B1
T1
H1
B = Width
T = Depth
Configuration:
Filter fan unit ready for installa-
tion, including drilling template,
filter mat and assembly parts.
Certifications,
see page 19.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. filter fan unit SK 3321.607 3321.6171) 3322.607 3322.6171) 3323.607 3323.6171)
Voltage V, Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60 230, 50/60 115, 50/60
Dimensions in mm (inches)
H1/B1 116 (4.6) 148 (5.8) 204 (8.0)
H2/B2 92 + 0.8 (3.6 + 0.03)2) 124 (4.9)2) 177 (7.0)2)
T1 10 (0.4) 10.5 (0.5) 12.5 (0.5)
Maximum installation depth
in mm (inches) T2 42 (1.7) 57 (2.2) 82 (3.2)
Air displacement, unimpeded air flow 20/25 m3/h (12/15 cfm) 55/66 m3/h (32/39 cfm) 105/120 m3/h (62/71 cfm)
Air displacement with outlet filter
including standard filter mat
1 x 3321.267:
15/18 m3/h (9/11 cfm)
1 x 3322.267:
43/50 m3/h (25/29 cfm)
2 x 3322.267:
48/55 m3/h (28/32 cfm)
1 x 3323.267:
48/55 m3/h (28/32 cfm)
1 x 3323.267:
71/82 m3/h (42/48 cfm)
2 x 3323.267:
85/98 m3/h (50/58 cfm)
1 x 3325.267:
78/90 m3/h (46/53 cfm)
Axial fan self-starting shaded pole motor
Rated current maximum 69 mA/
58 mA
138 mA/
115 mA
0.12 A/
0.11 A
0.24 A/
0.23 A
0.12 A/
0.11 A
0.24 A/
0.23 A
Power 12.5/10.3 W 19.0/18.0 W
Noise level 41/46 dB (A) 46/49 dB (A)
Temperature range –10°C to +55°C (13°F to 131°F)
Color RAL 7035 (light gray)3)
Ratings to EN 60 529/10.91 IP 54 (NEMA 12) standard
Part No. outlet filter – EMC SK 3321.267 3322.267 3323.267
Accessories PU Page
Spare filter mats 5 3321.700 3322.700 3171.100 113
Fine filter mats 5 – 3181.100 113
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 3114.115 3114.100 3114.115 3114.100 3114.115 103
Speed control 1 3120.000 3120.115 3120.000 3120.115 3120.000 3120.115 105
Hose-proof hood 1 3321.800 3322.800 3323.800 109
1) Delivery times available on request.
2) For metal thickness > 2.5 mm (0.1˝), the cutout H2/B2 (W) must be 1 mm (0.04˝) larger.
3) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
Filter Fan Unit – EMC
Air displacement 106/433 cfm
84 Climate Control
B
4.1
Filter Fan Unit – EMC
H2
B2
T2
B1
T1
H1
B = Width
T = Depth
Configuration:
Filter fan unit ready for installa-
tion, including drilling template,
filter mat and assembly parts.
Certifications,
see page 19.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. filter fan unit SK 3324.607 3324.6171) 3325.607 3325.617 3326.607 3326.6171) 3327.607 3327.6171)
Voltage V, Hz 230, 50/60 115, 50/60 230, 50/60 115, 50/60 230, 50/60 115, 50/60 230, 50/60 115, 50/60
Dimensions in mm (inches)
H1/B1 255 (10.0) 323 (12.7)
H2/B2 224 ( 8.8)2) 292 (11.5)2)
T1 12 (0.5) 12 (0.5)
Maximum installation depth
in mm (inches) T2 105 (4.1) 129 (5.1) 145 (5.7)
Air displacement,
unimpeded air flow 160/180 m3/h
(94/106 cfm) 230/265
(135/156 cfm) 550/600 m3/h
(324/353 cfm) 700/720 m3/h
(412/423 cfm)
Air displacement with outlet filter
including standard filter mat
1 x 3325.267
115/95 (68/56 cfm)
2 x 3325.267:
165/140 m3/h (97/82 cfm)
1 x 3326.267:
155/130 m3/h (91/77 cfm)
1 x 3325.267:
170/205 m3/h (100/120 cfm)
2 x 3325.267:
200/230 m3/h (118/135 cfm)
1 x 3326.267:
190/215 m3/h (111/127 cfm)
1 x 3325.267:
170/205 m3/h (100/121 cfm)
2 x 3325.267:
200/230 m3/h (118/135 cfm)
1 x 3326.267:
360/390 m3/h (212/230 cfm)
1 x 3326.267:
525/575 m3/h
(309/338 cfm)
Axial fan self-starting shaded pole motor Capacitor motor
Rated current maximum 0.19 A/
0.20 A
0.38 A/
0.40 A
0.28 A/
0.24 A
0.53 A/
0.49 A
0.29 A/
0.35 A
0.58 A/
0.70 A
0.65 A/
0.95 A
1.50 A/
2.00 A
Power 30.0/
35.0 W
41.0/
38.0 W
64.0/
80.0 W
155.0/
212.0 W
167.0/
230.0 W
Noise level 52/48 dB (A) 54/56 dB (A) 59/61 dB (A) 75/76 dB (A)
Temperature range –10°C to +55°C (13°F to 131°F)
Color RAL 7035 (light gray)3)
Ratings to EN 60 529/10.91 IP 54 (NEMA 12) standard
Part No. outlet filter – EMC SK 3325.267 3326.267
Accessories PU Page
Spare filter mats 5 3172.100 3173.100 3327.700 113
Fine filter mats 5 3182.100 3183.100 113
Thermostat 1 3110.000 104
Temperature indicator 1 3114.100 3114.115 3114.100 3114.115 3114.100 3114.115 3114.100 3114.115 103
Speed control 1 3120.000 3120.115 3120.000 3120.115 3120.000 3120.115 3120.000 3120.115 105
Hose-proof hood 1 3324.800 3326.800 109
1) Delivery times available on request.
2) For metal thickness > 2.5 mm (0.1˝), the cutout H2/B2 (W) must be 1 mm (0.04˝) larger.
3) RAL 7032 (pepple gray) on request.
Special voltages available on request. We reserve the right to make technical modifications.
85Climate Control
Climate Control Tailored to Enclosures
Features
B
4.1
Climate Control Tailored to Enclosures
All rack-mounted climate control components are mounted
directly on the 482.6 mm (19˝) rails. Positioning directly
beneath the electronic components ensures effective cool-
ing, and prevents the formation of hot spots.
Rack-mounted air conditioners
Simple attachment to the
482.6 mm (19˝) rails
Sealed enclosures require a door
cutout for the external air circuit.
A fully equipped front is essen-
tial in open enclosures. The set-
point of the temperature control-
ler is set by a service door.
Rack-mounted fan
Vario rack-mounted fan
The rack-mounted fan slides into
the guide frame like a drawer.
Connectors on the rear ensure
immediate contact.
Installation options for the guide
frame: Directly in the subrack,
by two mounting brackets on the
482.6 mm (19˝) rails.
Ideal for avoiding hot spots in
fully populated enclosures.
Centrifugal fan
320 m3/h (188 cfm)
air displacement, 2U
High air displacement means
that Rittal centrifugal fans are
capable of dissipating large heat
losses from the enclosure. Noise
generation of only 52 dB main-
tains a pleasant environment.
Front outlet grille 2U for hot air
outlet to the outside in the upper
section of the enclosure.
Useful cooling capacity
1000 W, 6U (3415 BTU, 6U)
The heated air is drawn in,
cooled, and blown out under-
neath the electronic equipment
that is being cooled.
86 Climate Control
Climate Control Tailored to Enclosures
Features
B
4.1
Climate Control Tailored to Enclosures
Fans for integration into the roof
For all enclosures:
Roof-mounted fans, passive
or active
May be integrated into any en-
closure roof area with suitable
dimensions for the mounting cut-
out.
For TS8 server enclosures:
Fan roof, modular
In exchange for the existing roof
plate. Fan and cable entry are
pre-integrated.
For the office sector:
Roof-mounted fan
Low noise generation and high
performance for sensitive office
areas. Unit consisting of TS roof
plate and fan.
Fan for integration into the door
For TS8 server enclosures:
Door-mounted fans for server
enclosures
Specifically for installation in the
tubular door frame of perforated
doors.
Door-mounted fans for TS8
server enclosures
Specifically for installing in per-
forated doors. The growing
packaging density in data com-
munications and network enclo-
sures means that active, direct
ventilation of the enclosure has
become necessary. The door-
mounted fans, attached to the
rear or front door, support hori-
zontal air routing of the servers.
Air baffle systems
For TS8 server enclosures:
Internal fan mounting panel
Twin-walled sidewall for tar-
geted air routing.
Enclosure internal fan
Supports active climate control
components and thereby
selectively avoids hot spots.
For TS8: Air baffle system
Cold air from the hollow base is
routed to the twin-walled door
and distributed in a targeted
manner.
Ready-to-use, wired modules equipped with fans for numer-
ous Rittal enclosure system platforms. Rittal Climate Control
offers effective air displacement and minimal assembly work.
Fan roofs, fan cross members for server enclosures (door
installation), internal fan mounting panels and enclosure
internal fans are all available.
For 482.6 mm (19˝), useful cooling capacity 1000 W (3586 BTU)
Rack-Mounted Air Conditioners
87Climate Control
B
4.1
Rack-Mounted Air Conditioners
H
B
T
B = Width
T = Depth
Configuration:
Wired ready for connection with
connection cable (3 m (118˝)),
including drilling template.
Also required:
For installation in a closed
enclosure:
Adaptor for front air supply and
air duct for waste air, see acces-
sories.
Certifications,
see page 19.
Detailed drawing,
see page 137.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. SK 3278.1341) 3292.134
Voltage V, Hz 115, 50/60 230, 50/60
Dimensions in mm (inches)
H
W
D
265.9 (10.5) 6 U
445 (17.5)
542 (21.3)
Useful cooling output QK
to DIN 3168 in W (BTU) L 35 L 35
L 35 L 50 1000/1050 (3415/3586)
660/770 (2254/2630)
Rated current maximum 8.4 A/10.8 A 3.8 A/4.5 A
Starting current 21.0 A/22.0 A 10.0 A/11.8 A
Pre-fuse T 10.0 A/16.0 A 6.0 A/6.0 A
Power consumption Pel
to DIN 3168
L 35 L 35
L 35 L 50
615/710 W
680/800 W
585/650 W
650/720 W
Cooling coefficient ε = QK/Pel L 35 L 35 1.6 1.7
Refrigerant R134a, 700 g
Maximum allowable operating pressure. 25 bar (363 psi)
Temperature and setting range +20°C to +55°C (68°F to 131°F)
Protection category
to EN 60 529/10.91
External circuit IP 34 (NEMA 2)
Internal circuit IP 54 (NEMA 12)
Duty cycle 100 %
Type of connection Connection cable 3 m (118˝)
Weight in kg (lb) 38 (88.8) 35 (77.2)
Color RAL 7032 (pebble gray)
Air displacement of fans External circuit 620 m3/h (365 cfm)
Internal circuit 460 m3/h (272 cfm)
Temperature control Internal thermostat (factory setting +35°C (95°F))
Accessories PU Page
Filter mats 3 3286.000 111
Adaptor for front air supply 1 3259.000 102
Air duct 10 3220.000 102
Temperature indicator 1 3114.115 3114.100 103
Door-operated switch 1 4127.000 –
1) Delivery times available on request.
Special voltages available on request. We reserve the right to make technical modifications.
.
.
Rack-Mounted Fans
For 482.6 mm (19˝), air displacement 188/283 cfm
88 Climate Control
B
4.1
Rack-Mounted Fans
426
482.6 (19˝)
206
214
55
432
120
1HE
482.6 (19˝)
180
200
73
410
100
1HE
12
HE = U
Rack-mounted fan/Vario rack-
mounted fan configuration:
Wired unit ready for connection,
including terminal strip and
assembly parts.
Guide frame supply includes:
Guide frame including connec-
tor and fitted connection cable
(3 m (118˝)), bracket for optional
attachment to the 19˝ system,
assembly parts.
Also required:
Remember to order the appro-
priate guide frame for your
chosen application.
Certifications,
see page 19.
Detailed drawing,
see page 137.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Rack-mounted fans Vario rack-mounted fans
Part No. SK Part No. SK
2 fans
Distance between axes
85 mm (3.3˝) 3340.0241) 3340.1151) 3340.230 – – 3350.0241) 3350.1151) 3350.230 –
3 fans
Distance between axes
85 mm (3.3˝) 3341.0241) 3341.115 3341.230 – 9769.0021) 2) 3351.0241) 3351.1151) 3351.230 –
3 fans
Distance between axes
105 mm (4.1˝) 3342.024 3342.1151) 3342.230 3342.5002) – 3352.0241) 3352.1151) 3352.230 3352.5001) 3)
Voltage V 24 V (DC) 115 V (AC) 230 V (AC)
24 V (DC)
115 – 230 V
(AC)
36 V (DC)
up to
72 V (DC)
24 V (DC) 115 V (AC) 230 V (AC)
24 V (DC)
115 – 230 V
(AC)
Part No. SK
matching guide frame – – – – – 3356.1001) 3355.100 3355.100 3357.1001)
Accessories Page
Temperature indicator
230 V (AC) 103 3114.100 3114.115 3114.100 3114.024 – 3114.100 3114.115 3114.100 3114.024
Thermostat 104 3110.000
Speed control 105 3120.000 3120.115 3120.000 – – 3120.000 3120.115 3120.000 –
1 2
Technical specifications
Part No. SK/CS 3340.230
3350.230 3340.115
3350.115 3340.024
3350.024
3341.230
3351.230
3342.230
3352.230
3341.115
3351.115
3342.115
3352.115
3341.024
3351.024
3342.024
3352.024
3342.5002)
3352.5002) 9769.002
Voltage V, Hz
AC 230 V
50/60 Hz
AC 115 V
50/60 Hz
DC 24 V
–
AC 230 V
50/60 Hz
AC 115 V
50/60 Hz
DC 24 V
–
DC 24 V
AC 115 – 230 V
50/60 Hz
36 V (DC)
up to
72 V (DC)
Rated current maximum 0.24 A/
0.22 A
0.46 A/
0.46 A 0.49 A 0.36 A/
0.33 A
0.69 A/
0.69 A 0.74 A 0.85 A 0.28 A
Pre-fuse T 6 A 6 A
Number of fans 2 3 3
Air displacement,
unimpeded air flow 320 m3/h (188 cfm) 480 m3/h (283 cfm) 250 m3/h (147 cfm)
Temperature range –10°C to +55°C (14°F to 131°F) –33°C to +55°C
(–27.4°F to 131°F)
Noise level 51 dB (A) 52 dB (A) 51 dB (A) 51 dB (A) 52 dB (A) 51 dB (A) 52 dB (A)
1) Delivery times available on request.
2) Rack-mounted fan for metric mounting angles available on request.
3) Version with monitoring.
Air displacement 188 cfm
Centrifugal Fan
89Climate Control
B
4.1
Centrifugal Fan
88
482.6 (19˝)
163
380
17
Configuration:
Fully assembled and wired unit,
ready for connection, including
filter mat.
Approvals,
see page 20.
Detailed drawing,
see page 137.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Accessories Page 100
Part No. SK 3145.000 3144.000
Voltage V, Hz 115, 50/60 230, 50/60
Dimensions in mm (inches)
H
W
D
88 (3.5) 2U
482.6 (19)
158 (6.2)
Air displacement, unimpeded air flow 320 m3/h (188 cfm)
Rated current maximum. 0.32 A 0.16 A
Power 37 W
Noise level 52 dB (A)
Speed 2245 rpm–1
Temperature range –10°C to +55°C (14°F to 131°F)
Maximum static pressure difference 65 – 70 Pa
Accessories PU Page
Temperature indicator 1 3114.115 3114.100 103
Thermostat 1 3110.000 104
Filter mats 5 3177.000 111
Front outlet grille 2U 1 3176.000 110
Roof vent 1 3148.007 90
Speed control 1 3120.115 3120.000 105
Special voltages available on request. We reserve the right to make technical modifications.
Fan Systems
For TS8 server enclosures
90 Climate Control
B
4.1
Fan Systems
Roof-mounted fan and
vent attachment
For TS8 server enclosures
The active roof-mounted fan and the passive vent
attachment (TS8801.380) integrate perfectly into
the system wide mounting concept of Rittal Cli-
mate Control. They fit onto the cutouts of the small
and medium performance category of TopTherm
roof-mounted air conditioners.
They may also be mounted on any sufficiently
large roof surface.
TS8 roof plates with prepared mounting cutouts
are also available.
Roof-mounted fan configuration:
Unit ready to connect with built-in radial fan,
sealing material and assembly parts.
Vent attachment:
see page 107.
Rating:
IP 43 to EN 60 529/10.91
Detailed drawing,
see page 138.
T
B
290
500
370
550
125
B = Width
T = Depth
Part No. SK 3149.410 3149.420 3149.440 3149.810 3149.820 3149.840 8801.380 Page
Voltage V, Hz 115,
50/60 230, 50/60 400, 3~, 50/60
460, 3~, 60
115,
50/60 230, 50/60 400, 3~, 50/60
460, 3~, 60 Roof vent
Air displacement, unimpeded air flow 400 m3/h (235 cfm) 800 m3/h (471 cfm) Without
motor
Required mounting cutout
in mm (inches)
B
T
475 (18.7)
260 (10.2)
490 (19.3)
390 (15.4)
Power consumption of fan 120/170 W 95/140 W 170/225 W 180/310 W
Rated current of fan 1.1/1.6 A 0.55/0.88 A 0.35/0.35 A 1.5/2.2 A 0.75/1.1 A 0.35/0.55 A
Temperature range –10°C to +55°C (14°F to 131°F)
Noise level 68/69 dB (A) 69/70 dB (A)
Weight in kg (lb) 10 (22.0) 11 (24.3)
Color shade RAL 7035 (light gray)
Accessories
Roof plate 600 x 600 mm (23.6 x 23.6˝) for TS8 with cutout 8801.300 8801.310 107
Roof plate 600 x 800 mm (23.6 x 31.5˝) for TS8 with cutout 8801.320 8801.330 107
Roof plate 1200 x 600 mm (47.2 x 23.6˝) for TS8 with cutout – 8801.350 107
Temperature indicator 3114.115 3114.100 – 3114.115 3114.100 – – 103
Speed control 3120.115 3120.100 – 3120.115 3120.100 – – 105
Roof-mounted fan
●The roof-mounted fan is easily installed using
6 screws. The sealing tape supplied can be
used to seal the fan against the enclosure.
●The assembly screws are invisible from the
outside.
●The roof-mounted fan casing has a large air
outlet surface and labyrinthine air ducting.
Rating:
IP 43 to EN 60 529/10.91.
By additionally installing the filter holder with filter
mat SK 3175.000, with roof vent SK 3148.000 a
rating of IP 44 is achieved.
Configuration:
Fully wired unit ready for connection with built-in
radial fan, sealing material and assembly parts,
connection cable (3 m (118˝)), drilling template.
Accessories:
Filter holder,
see page 110.
Detailed drawing,
see page 138.
50
265
345
340
420
Part No. SK 3149.007 3169.007 3148.007
Voltage V, Hz 230, 50/60 115, 50/60 Without fan motor
Air displacement 360 m3/h (212 cfm)
Rated current maximum 0.2 A 0.55 A
Power consumption 42 W 65 W
Temperature range –10°C to +60°C (50°F to 140°F)
Noise level 53 dB (A)
Weight in kg (lb) 7.8 (17.2)
Color1) RAL 7035 (light gray), textured enamel
1) To order the version in RAL 7032 (pepple gray), please add extension .000 to the Part no.
Special voltages available on request. Technical modifications reserved.
For TS/FR(i)
Fan Systems
91Climate Control
B
4.1
Fan Systems
Roof-mounted fan
For TS/FR(i) for the office sector
This new roof ventilation concept offers a wealth
of performance, assembly and cost benefits asso-
ciated with the use of integrated ventilation sys-
tems. This roof-mounted fan may be ordered with
or without a roof plate. The enormous volumetric
flow in proportion to exceptionally low noise lev-
els make the roof-mounted fan ideal for use in
sensitive office areas.
Technical specifications:
●Fitted onto a roof plate based on a TS8 server
enclosure
●Easy assembly; the work of creating mounting
cutouts has been eliminated
●Radial fan
Configuration:
Fully wired ready for connection,
including assembly parts.
T
H
B
511
511
410
450
450
410
H
13.5
T
B
20
24
450
225
18
205
410
Ø 6.5
(8x)
B = Width
T = Depth
Part No. SK 3164.610 3164.620 3164.810 3164.820 3164.115 3164.230 Page
Voltage V, Hz 115, 50/60 230, 50/60 115, 50/60 230, 50/60 115, 50/60 230, 50/60
Air displacement (unimpeded air flow) 1500 m3/h1) (883 cfm)
Version with roof plate without roof plate
Dimensions in mm (inches)
H
B
T
240 (9.5)
800 (31.5)
800 (31.5)
240 (9.5)
800 (31.5)
900 (35.4)
227 (8.9)
511 (20.1)
511 (20.1)
Power consumption 6.8/8.1 W
Rated current 0.6 A/0.7 A 0.3 A/0.35 A 0.6 A/0.7 A 0.3 A/0.35 A 0.6 A/0.7 A 0.3 A/0.35 A
Radial fan –
Noise level 40 dB (A)
Temperature range +20°C to +55°C (68°F to 131°F)
Color RAL 7035 (light gray)
Accessories
Temperature indicator in 1U patch panel 7109.035 103
Temperature indicator 3114.115 3114.100 3114.115 3114.100 3114.115 3114.100 103
Thermostat 3110.000 104
1) 800 m3/h (471 cfm) at 40 Pa counterpressure using two integrated louvers, type DK 7580.500, in the enclosure base/plinth.
Special voltages available on request. Technical modifications reserved.
Mounting cutout
only required for fans without roof plate
TS8 air baffle system
The system has an air inlet nozzle in the base
frame. Cold air is drawn in from below and routed
into the twin-walled door. The cold air is then dis-
tributed inside the rack with special covers.
15 covers are supplied with every door.
Color:
RAL 7035 (light gray)
H x W PU Part No. DK
TS8 sheet steel door, twin-walled
2000 x 600 mm (78.7 x 23.6˝) 17766.520
TS8 sheet steel door, twin-walled
2200 x 600 mm (86.6 x 23.6˝) 17766.522
Air inlet nozzle
600 mm (23.6˝) 17766.500
Fan Systems
For TS/FR(i)
92 Climate Control
B
4.1
Fan Systems
Fan mounting panel
For TS8 network enclosures
The fan mounting panel may be retroactively
installed in all TS8 network enclosures from
above. The plate is mounted at the front of the
enclosure and the rear section is left free for cable
entry. To ensure targeted air routing a rubber
cable clamp strip is supplied loose for optimum
sealing at the rear and sides.
Not suitable for crane transportation.
Not suitable for combination with 482.6 mm (19˝)
mounting frame.
The following combinations are possible:
●Solid roof plate raised with 20 or 50 mm
(0.8 or 2.0˝) roof spacers
●Roof plate for cable entry raised
with 20 or 50 mm (0.8 or 2.0˝) roof spacers
●Vented roof plate for cable entry
In conjunction with the large swing frame, usage
is only possible from an enclosure depth of
800 mm (31.5˝), in conjunction with a roof plate for
cable entry from 900 mm (35.4˝).
The air displacement can be increased with the
fan expansion kit DK 7980.000.
Technical specifications for one fan:
Voltage: 230 V
Power consumption: 15/14 W at 50/60 Hz
Air displacement (unimpeded air flow):
160/180 m3/h, 50/60 Hz (94/106 cfm)
Temperature range:
–10°C to +55°C (14°F to 131°F)
Technical specifications of thermostat:
Voltage: 250 V
Temperature range:
+5°C to +55°C (41°F to 131°F)
Color:
RAL 7035 (light gray)
Configuration:
2 fans, 2/4 cutouts to extend to
4/6 fans, thermostat optional for attachment to the
fan mounting panel or to the 25 mm (1˝) DIN pitch
pattern of the enclosure,
Rubber cable clamp strip.
Thermostat and fan fully wired to connection
cable (2.5 m (98.4˝)).
Accessories:
Fan expansion kit,
see below.
385/585
525/725
40
30
For modular enclosures
mm (inches) No.
of
fans
Max.
no. of
fans
Part No.
DK
Width Depth
600 (23.6) 600 (23.6) 2 4 7966.035
600 (23.6)
800 (31.5)
900 (35.4)
1000 (39.4)
267968.035
800 (31.5) 600 (23.6) 2 6 7986.035
800 (31.5)
800 (31.5)
900 (35.4)
1000 (39.4)
267988.035
Fan expansion kit
For retrofitting various fan units or to supplement
the fan mounting panel and fan roof, modular.
Technical specifications DK 7980.000:
Voltage: 230 V~
Power consumption: 15/14 W at 50/60 Hz
Air displacement (unimpeded air flow):
160/180 m3/h (94/106 cfm), 50/60 Hz
Noise level (unimpeded air flow): 37 dB (A)
Temperature range:
–10°C to +55°C (14°F to 131°F)
Technical specifications DK 7980.100:
Voltage: 230 V~
Power consumption: 14/12 W at 50/60 Hz
Air displacement (unimpeded air flow):
108/120 m3/h (64/71 cfm), 50/60 Hz
Noise level (unimpeded air flow): 34 dB (A)
Temperature range:
–20°C to +70°C (–4°F to 158°F)
Technical specifications DK 7980.148:
Voltage: 48 V (DC)
Power consumption: 7.7 W
Air displacement (unimpeded air flow): 184 m3/h
Noise level (unimpeded air flow): 42 dB (A)
Temperature range:
–20°C to +70°C (–4°F to 158°F)
Configuration:
Fan, including assembly parts and connection
cable (0.61 m (24.0˝)).
Dimensions
H x W x D
mm (inches)
PU Part No. DK
119 x 119 x 38
(4.7 x 4.7 x 1.5) 1 set 7980.000
119 x 119 x 25
(4.7 x 4.7 x 1.0) 1 set 7980.100
119 x 119 x 25
(4.7 x 4.7 x 1.0) 1 set 7980.148
DC fan mounting panel
Fan Systems
93Climate Control
B
4.1
Fan Systems
DC fan mounting panel
For TS8 server enclosure
Low-noise due to FCS speed control,
fully fitted
Suitable for TS8 modular enclosures with a raised
roof (> 20 mm (0.8˝)) or TS8 roof plate, vented.
The fan mounting panel may be used as an alter-
native to fan mounting panel 7988.035. It is
installed from above. A cable entry is prepared in
the rear section of the plate.
Not suitable for combination with 482.6 mm (19˝)
mounting frame.
Advantages of the DC fan mounting panel with
FCS technology:
●Low-noise due to speed control
●All fans are individually monitored for failure
●High air displacement due to DC technology
(unimpeded air flow 6 x 165 m3/h (97 cfm) =
990 m3/h (583 cfm))
●EMC-compatible due to DC fan
●Temperature monitoring and control
●High level of safety due to low safety voltage
with 24 V DC power pack
●Visual and acoustic alarm messages, and relay
alarm output
●Freely selectable installation location for the
FCS control unit (included with the supply of the
fan mounting panel, in 482.6 mm (19˝) with
7320.440 or on the frame with 7320.450)
●Suitable for international use, due to wide-range
power pack 100 – 240 V AC and socket to
IEC 320
●Fully pre-configured
●Network compatible by CMC-TC processing
unit 7320.100 (all relevant data such as
temperature is displayed in the web browser, or
alarms are sent in the form of an SNMP trap)
Technical specifications:
Power pack voltage:
100 – 240 V AC, 50/60 Hz
Power pack rated current: Max. 1.5 A
Power pack secondary range: 24 V DC, 3 A
Temperature range:
+5°C to +40°C (41°F to 104°F)
Total air displacement (unimpeded air flow):
6 x 165 m3/h (97 cfm) = 990 m3/h (583 cfm)
Technical specifications for one fan:
Voltage: 24 V DC
Rated current: max. 0.28 A
Rated output: max. 6.72 W
Air displacement (unimpeded air flow):
165 m3/h (97 cfm)
Speed: 2650 rpm
Noise level: up to 41.0 dB (A)
at maximum speed activation
Also required:
Connection cable 230/115 V.
Example D version, Part no. 7200.210.
Accessories:
1U mounting unit, Part no. 7320.440.
Mounting module, Part no. 7320.450.
For modular
enclosures
width
mm (inches)
For modular
enclosures
depth
mm (inches)
Number
of
DC fans
Part No.
DK
800 (31.5)
800 (31.5)
900 (35.4)
1000 (3.9)
67858.488
Fan Systems
For TS/FR(i)/TE
94 Climate Control
B
4.1
Fan Systems
Fan roof, modular,
two-piece
For TS/FR(i)
The modular roof plate consists of individual com-
ponents and can be configured for the ventilation
of TS8 modular enclosures in line with customer
requirements.
The modules:
Roof plate, two-piece with cutout
For fan mounting and cable entry at the rear by a
sliding angular bracket with rubber cable clamp
strip. In exchange for the existing roof plate. The
two-piece design allows convenient retrofitting of
cables at any time.
Cover plate
To cover the cutout, available solid or vented. The
top-mounted cover plate may be raised for extra
air displacement using the supplied spacers.
Fan insert
For active ventilation:
A fully pre-wired fan tray including 2.5 m (98.4˝)
connection cable, with two fan motors and addi-
tional cutouts. The air displacement may be
increased with a fan expansion kit.
Material:
Sheet steel, painted
Color:
RAL 7035 (light gray)
Technical specifications for one fan:
Voltage: 230 V
Power consumption: 15/14 W at 50/60 Hz
Air displacement (unimpeded air flow):
160/180 m3/h (94 to 106 cfm) at 50/60 Hz
Temperature range:
–10°C to +55°C (14°F to 131°F)
Detailed drawing,
see page 138.
Accessories:
Fan expansion kit DK 7980.000.
Thermostat SK 3110.000,
see page 104.
Speed control SK 3120.000,
see page 105.
1
23
4
For modular
enclosures
mm (inches)
Part No. DK Fan insert
Roof plate Cover plate
Width Depth With cutout Solid Vented Fan insert
Fan
pre-wired
Maximum
no. of
fans
600
(23.6)
600 (23.6) 7826.366 2102.180 2102.400 2102.320 22
800 (31.5) 7826.368 2102.190 2102.410 2102.490 26
900 (35.4) 7826.369 2102.190 2102.410 2102.490 26
1000 (39.4) 7826.360 2102.190 2102.410 2102.490 26
800
(31.5)
600 (23.6) 7826.486 7885.100 7885.200 7885.000 23
800 (31.5) 7826.488 7886.100 7886.200 7886.000 28
900 (35.4) 7826.489 7886.100 7886.200 7886.000 28
1000 (39.4) 7826.480 7886.100 7886.200 7886.000 28
1 3 4 2
Fan unit, active
For TE 7000
For active ventilation of the TE 7000, a ventilation
opening may be cut out of the front area in the
standard roof plate and fitted with the fan mod-
ule. The fan module is pre-wired ready for con-
nection and has 2 fans, 1 thermostat and a con-
nection cable including IEC 320 connector. An
additional fan may be integrated.
Configuration:
Fan unit including assembly parts, 2 fans,
thermostat and connection cable.
Technical specifications for one fan:
Fan extension kit.
Technical specifications of thermostat:
Voltage: 250 V
Temperature range:
+5°C to +55°C (41°F to 131°F)
Also required:
Connection cable.
Accessories:
Fan expansion kit.
For enclosures
W x D
mm (inches)
Number of
pre-wired
fans
Possible
number of
fans
Part No.
TE
All
dimensions 237000.670
For TS8 modular server enclosures
Fan Systems
95Climate Control
B
4.1
Fan Systems
Door mounted fan
For TS8 modular server enclosures,
especially for installing in perforated doors.
The growing packaging density in data communi-
cations and network enclosures make active,
direct ventilation of the enclosure necessary. The
door mounted fan, which is attached to the rear or
front door, supports horizontal air routing for the
servers and therefore facilitates faster heat dissi-
pation from active components.
Technical specifications:
●Standard cross member with two fans.
●Air displacement, unimpeded air flow 600 m3/h
(353 cfm).
●By adding two fan expansion kits, the air
displacement may be increased to 1200 m3/h
(706 cfm).
●The direction of air flow is easily reversed by
rotating the fan.
●Several units may be positioned in a cascade
arrangement.
●Simple mounting on the tubular door frame.
Configuration:
Wired ready for connection with 2.5 m (98˝)
connection cable, including assembly parts.
Accessories:
Fan expansion kit,
see below.
Note:
Only for mounting on the tubular door frame.
Door configuration for installation in 2- and 4-door
ISP racks available on request.
B
T
H
552
27
250 (450)
Ø 4.5
475 (675)
493 (693)
606
9
59.5
5
Part No. SK 3165.6241) 3165.6481) 3165.6151) 3165.6301) 3165.8241) 3165.8481) 3165.8151) 3165.8301) Page
Voltage V, Hz 24 (DC) 48 (DC) 115, 50/60 230, 50/60 24 (DC) 48 (DC) 115, 50/60 230, 50/60
Air displacement
(unimpeded air flow) 600 m3/h (353 cfm)
Power consumpion for two fans 40 W 48 W 70 W/64 W 70 W/70 W 40 W 48 W 70 W/64 W 70 W/70 W
Rated current of fan 1.5 A 1.0 A 0.76 A/0.72 A 0.38 A/0.36 A 1.5 A 1.0 A 0.76 A/0.72 A 0.38 A/0.36 A
Dimensions in mm (inches)
H
B
T
606 (23.9)
493 (19.4)
64.5 (2.5)
606 (23.9)
693 (27.3)
64.5 (2.5)
For doors with width in mm (inches) 600 (23.6) 800 (31.5)
Noise level 55 dB (A)
Temperature range +20°C to +55°C (68°F to 131°F)
Color RAL 7035 (light gray)
Accessories
Temperature indicator 3114.024 – 3114.115 3114.100 3114.024 – 3114.115 3114.100 103
Thermostat 3110.000 104
1) Delivery times available on request.
Special voltages available on request. Technical modifications reserved.
B = Width
T = Depth
Fan expansion kit
For door mounted fan
To increase the air displacement of the door
mounted fan.
To fit
door mounted fan Part No. SK
3165.624, 3165.824 3165.024
3165.648, 3165.848 3165.048
3165.615, 3165.815 3165.115
3165.630, 3165.830 3165.230
Fan Systems
For TS8 modular server enclosures
96 Climate Control
B
4.1
Fan Systems
Internal fan mounting panel
For TS8 modular server enclosures
A fan unit integrated into the TS8 twin wall for
targeted air routing in the lower part of the en-
closure. A second fan unit may optionally be
mounted to reinforce air circulation. Optional air
routing design may be achieved retroactively by
inserting or exchanging cover plates.
Technical specifications:
●Voltage:
230 V, 50/60 Hz
●Air displacement (3 fans): (unimpeded air flow)
200/230 m3/h (118/135 cfm)
●Power consumption (3 fans): 57/54 W
●Rated current (3 fans): 0.36/0.33 A
Configuration:
1 pack =
1 internal fan mounting panel,
3 fan cross members,
3 cover plates.
Property rights:
German patent no. 198 04 219
European patent no. 1 053 581
with validity for ES, FR, GB, IT
Australian patent no. 737 950
US patent no. 6,494,779
For TS8 enclosure
mm (inches) Height of
internal panel
mm (inches)
Part No.
SK
Width Height
600
(23.6)
1800 (70.9) 1548 (61.0) 3347.180
2000 (78.7) 1748 (68.8) 3347.200
80
(31.5)
1800 (70.9) 1548 (61.0) 3348.180
2000 (78.7) 1748 (68.8) 3348.200
Fan cross member
For internal fan mounting panel
May be added to increase the air circulation.
Technical specifications:
●Voltage:
230 V, 50/60 Hz
●Air displacement (3 fans): (unimpeded air flow)
200/230 m3/h (118/135 cfm)
Property rights:
German patent no. 198 04 906
European patent no. 1 053 662
with validity for ES, FR, GB, IT
Australian patent no. 737 485
US patent no. 6,315,656
Chinese patent no. ZL 988 13378.4
PU Part No. SK
33349.100
Cover plates
For internal fan mounting panel
For optional design of the air routing.
PU Part No. SK
33349.300
Enclosure internal fan
For TS8 modular server enclosures
To prevent hot spots and support the air routing
of active enclosure climate control components.
Adjustable in two axes. Attached to the TS8 frame
section. Several fans may be cascaded using the
quick-release clamping strip.
Configuration:
Fully wired unit ready for connection with radial
fan and lockable swivel bracket, and assembly
parts.
213.5
100
120
Ø 6 (2x)
Air displace-
ment,
unimpeded
air flow
Power
consump-
tion
W
Rated
current
A
Voltage
V, Hz Part No.
SK
160 m3/h
(94 cfm)
19.0/18.0 0.12/
0.11
230,
50/60 3108.100
19.0/18.0 0.24/
0.23
115,
50/60 3108.115
3.5 0.15 24 V (DC) 3108.024
97Climate Control
Heaters
Features
B
4.1
Heaters
Condensation poses a high risk for control electronics, in out-
door and indoor locations. Various output ratings ensure that
the correct thermal output is always available. Therefore the
total required thermal output can be distributed with com-
plete accuracy inside an enclosure.
Simple assembly and perfect control
Fast assembly
This is achieved with a screw or
snap fastening on the mounting
panel or 35 mm (1.4˝) EN 50 022
support rails.
No condensation, and always
the right temperature
The heater is controlled as
required by a hygrostat or
enclosure internal thermostat.
Maximum performance in the outdoor sector
Fully wired unit ready for
connection
Compact power with 1000 W
(3415 BTU) thermal output.
19˝ rack mount
For seamless integration into the
482 mm (19˝) structure, with
3 thermal components and 3 fan
units. This creates circulation, so
that condensation is reliably
avoided.
Benefits:
●Continuous thermal output
of 10 to 1000 W (34 to
3415 BTU)
●Self-regulating PTC
technology
●Quick-assembly system
Important:
●For the correct temperature
and to avoid condensation,
use a thermostat or hygro-
stat,
see page 104
●The thermal output is
increased with fans
●Heaters should always be
installed in an upright posi-
tion. Leave a distance of
50 mm (2.0˝) at the top and
bottom to allow circulation
●Heat is distributed evenly in
large enclosures by using
several low-output heaters
General remarks
and calculation formulas
can be found on our website:
www.rittal-corp.com
Enclosure Heaters
Continuous thermal output 10 – 300 W (34 – 1025 BTU)
98 Climate Control
B
4.1
Enclosure Heaters
Axial fan
For heater SK 3107.000
Ball bearing
Temperature range:
–40°C to +85°C (–40°F to 185°F)
Voltage:
230 V, 50/60 Hz
Power consumption: 18 watts
Noise level: 33 dB (A)
Speed: 2800/3300 rpm
Air displacement: 50 m3/h (29 cfm)
PU Part No. SK
13108.000
T
H
B
T
H
B
B = Width
T = Depth
Configuration:
Unit is ready to install with per-
manently attached connection
cable (0.3 m (11.8˝)).
SK 3102.000 with fitted fan
including terminal strip.
Note:
●Thermostat SK 3110.000
(see accessories) is recom-
mended for precise tempera-
ture control in the enclosure
●In order to prevent condensa-
tion on assemblies, hygrostat
SK 3118.000 (see accesso-
ries) is recommended to regu-
late heating
●In larger enclosures, even
heat distribution is best
achieved by installing several
low-output heaters
●Installation in the enclosure is
generally advisable, even
when using heat exchangers
and air conditioners, in order
to prevent condensation
Certifications,
see page 21.
Detailed drawing,
see page 138.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
Part No. SK 3105.000 3106.000 3115.000 3116.000 3107.000 3107.000 +
3108.000 3102.110
(incl. fan) 3102.000
(incl. fan)
Dimensions in mm (inches)
H
B
T
75 (2.9)
45 (1.8)
35 (1.4)
125 (4.9)
45 (1.8)
35 (1.4)
110 (4.3)
64 (2.5)
45 (1.8)
185 (7.3)
64 (2.5)
45 (1.8)
140 (5.5)
80 (3.1)
118 (4.6)
178 (7.0)
80 (3.1)
118 (4.6)
168 (6.6)
120 (4.7)
120 (4.7)
168 (6.6)
120 (4.7)
120 (4.7)
Voltage V, Hz 110 – 240 (AC/DC) 230, 50/60 115, 50/60 230, 50/60
Continuous thermal output at Tu = 20°C in W (BTU) 10 (34) 20 (68) 30 (102) 50 (171) 130 (444) 200 (683)1) 300 (1025)1) 300 (1025)1)
Pre-fuse T 2 A 4 A
Accessories PU Page
Thermostat 1 3110.000 104
Hygrostat 1 3118.000 104
Temperature indicator 1 3114.000 103
1) Output with fan
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Page 100
For CS outdoor enclosures, continuous thermal output 600/1000 W (2049/3415 BTU)
Enclosure Heaters
99Climate Control
B
4.1
Enclosure Heaters
1 2
H
B
T
H
B
T
B = Width
T = Depth
Enclosure heater
Heater module
Material:
Enclosure: Aluminum
Finish:
Natural, 9763.023 with painted
front panel
Supply includes:
Fully wired unit ready for
connection with permanently
attached connection cable.
Fully wired unit ready for
connection, designed as a
482.6 mm (19˝) rack mount
with 3 thermal components
and 3 fan units.
Certification,
see page 21.
Detailed drawing,
available on the Internet,
log onto www.rittal-corp.com.
Performance diagrams,
available on the Internet,
log onto www.rittal-corp.com.
1
2 1
2
Part No. CS 9769.015 9769.023
Installation in the enclosure 19˝ mounting rails
Dimensions in mm (inches)
H
B
T
82 (3.2)
325 (12.8)
220 (8.7)
87.2 (3.4) 2U
482.6 (19)
236 (9.3)
Voltage V, Hz 230 (AC), 50/60 230 (AC), 50/60
Continuous thermal output in W (BTU) 1000 (3415) 600 (2049)
Rated current maximum 5.0 A 2.6 A
Temperature range –33°C to +65°C (–27°F to 149°F) –33°C to +65°C (–27°F to 149°F)
Air displacement, unimpeded air flow 120 m3/h (70.6 cfm) 480 m3/h (283 cfm)
Type of connection Connection cable with wire end ferrules Via front IEC connector (3-pole)
Weight in kg (lb) 3.0 (6.6) 3.1 (6.8)
Accessories PU Page
Thermostat 1 3110.000 3110.000 104
Hygrostat 1 3118.000 3118.000 104
Accessories Page 100
100 Climate Control
Accessories For Climate Control
Features
B
4.1
Accessories For Climate Control
Finding the perfect climate control solution is easier than ever
with matching system accessories. Perfectly coordinated
components adapt the climate control components to your
specific requirements. Be it targeted air routing or precise
control of the equipment, Rittal has the ideal solution for any
application.
Air routing
Controller
Installation/maintenance
Fast assembly
Easy installation with prepared
TS8 modular enclosure roof
plates.
Hose-proof hoods
For ratings IP 55 (NEMA 12) to
EN 60 529/10.91 with filter fan
units and outlet filters.
Filter mats
For use in air conditioners under
extreme conditions.
Air duct system for TopTherm
roof-mounted air conditioner
and air/water heat exchanger
With the air duct system, cold air
may be routed directly to spe-
cific areas of the enclosure.
Air diverter
For targeted, downward cold air
routing in climate controlled enclo-
sures, climate control doors and
TopTherm wall-mounted air con-
ditioners.
Adaptor
For unhindered front air intake
when using rack-mounted air
conditioners in enclosures with
front doors.
Enclosure internal thermostat
and hygrostat
Constant temperature and
humidity control to protect sensi-
tive electronics.
Speed control
Temperature-dependent speed
control to minimize noise and
save energy in part-load opera-
tion.
SK bus system
SK bus system with master/slave
function to enable several air
conditioners to communicate
with one another.
Air routing
Accessories For Climate Control
101Climate Control
B
4.1
Accessories For Climate Control
Air duct system
For TopTherm roof-mounted air conditioners
The air duct system for Rittal TopTherm roof-
mounted air conditioners makes it possible to
route the cold air directly to specific areas of the
enclosure. The risk of short circuits in the air circu-
lation due to self-ventilated installed devices is
eliminated.
The length of the flat duct is 1500 mm (59˝), and it
may be cut to the desired length.
Material:
Flame-resistant plastic to DIN 4102/B1.
Configuration:
Flat duct, compensating hose.
Accessories:
90° deflector.
Cover plugs.
Note:
Do not direct cold air straight at active compo-
nents. When using the ducting system, the perfor-
mance of the air conditioner may be reduced,
depending on the application in question.
For air conditioner PU Part No.
Air duct system SK
SK 3382. . . ./SK 3383. . . ./SK 3384. . . ./SK 3385. . . ./SK 3273. . . . /SK 3359. . . . 1 3286.870
SK 3386. . . ./SK 3387. . . . 1 3286.970
90° deflector
For air duct system
For targeted air deflection at the end of the flat
channel.
Material:
Flame-resistant plastic to DIN 4102/B1.
PU Part No. SK
13286.990
Plugs
For TopTherm roof-mounted air conditioners
To cover unneeded cold air outlets in TopTherm
roof-mounted air conditioners.
Material:
Polyurethane foam
For air conditioner PU Part No. SK
SK 3382. . . ./SK 3359. . . . 2 3286.780
SK 3383. . . ./SK 3384. . . ./SK 3385. . . ./SK 3273. . . . 2 3286.880
SK 3386. . . ./SK 3387. . . . 2 3286.980
Accessories For Climate Control
Air routing
102 Climate Control
B
4.1
Accessories For Climate Control
Air diverter
For use in climate controlled enclosures, climate
control doors, climate control sidewalls and Top-
Therm wall-mounted air conditioners.
For targeted routing of the cold air in a downward
direction.
Particularly well-suited for densely-packed electri-
cal components in the lower section of the enclo-
sure.
Material:
Sheet steel
651)
External
air circuit
Internal air
circuit
1) 115 mm (4.5˝) for SK 3213.330
For devices Part No. SK
SK 8607. . . ./SK 8687. . . .
SK 3306. . . ./SK 3331. . . . 3213.300
SK 3304. . . ./SK 3305. . . . 3213.310
SK 3328. . . ./SK 3329. . . . 3213.320
SK 3332. . . . 3213.3301)
Adaptor
For front air infeed
When using rack-mounted air conditioners
SK 3278.134/SK 3292.134 in enclosures with front
doors (sheet steel or acrylic), this adaptor must
be used. It allows ambient air to be extracted
unhindered from outside, which is essential for
correct functioning of the air conditioner.
Material:
Sheet steel
Configuration:
Adaptor, sealing gasket, foamed plastic gasket,
assembly parts.
15
62
327
232
50 27.5
100 190
35 31.75
12.7
63
62
b x 44.45 = c
PU Part No. SK
13259.000
Air duct
For discharge of waste air
For use of rack-mounted air conditioners
SK 3292.134/SK 3278.134 in enclosures with a
depth > 600 mm (23.6˝). The heated ambient air
is blown backwards out of the enclosure through
the air duct. The air duct may be extended as
required.
Material:
ABS plastic
Configuration:
Air duct including attachment clamps.
22
Air duct, may be extended to any length
PU Part No. SK
10 3220.000
Regulation/control
Accessories For Climate Control
103Climate Control
B
4.1
Accessories For Climate Control
Digital enclosure internal
temperature display and
thermostat
For installing on the enclosure door or wall and in
an air conditioner or heat exchanger.
Technical specifications:
●Small dimensions
●Depth: 100 mm (3.9˝)
●The 3-digit 7-segment display is 13 mm (0.5˝)
high and clearly legible
●Can be switched from °C/°F
●The display can be used in a temperature
range from +5°C to +70°C (41°F to 158°F)
●With 1500 mm (59˝) long NTC sensor
●Two relay outputs as change-over contact and
normally open contact (maximum contact load
230 V, 6 A)
●Freely selectable switching difference
●The freely adjustable setpoint values can be
adjusted by the membrane keyboard at the
front. Setting range: +5°C to +55°C (41°F to
131°F)
●Display and switching accuracy +/– 2 K
●Mounting cutout 68 x 33 mm (2.7 x 1.3˝)
●Storage of the minimum and maximum
recorded temperature until the system is reset
Voltage Part No. SK
230 V (AC) 3114.100
115 V (AC) 3114.1151)
24 V (DC) 3114.0241)
1) Delivery times available on request.
Special requirements available on request.
Digital enclosure internal
temperature display and
thermostat
Integrated into a patch panel 1 U.
Including cable attachment for connection cable
and label holder.
Voltage: 230 V (AC)
Special voltages available on request.
Technical specifications:
●Small dimensions
●Depth: 100 mm (3.9˝)
●The 3-digit 7-segment display is 13 mm (0.5˝)
high and clearly legible
●Can be switched from °C/°F
●The display can be used in a temperature
range from +5°C to +70°C (41°F to 158°F)
●With 1500 mm (59˝) long NTC sensor
●Two relay outputs as change-over contact and
normally open contact (maximum contact load
230 V, 6 A)
●Freely selectable switching difference
●The freely adjustable setpoint values can be
adjusted by the membrane keyboard at the
front.
Setting range: +5°C to +55°C (41°F to 131°F)
●Display and switching accuracy +/– 2 K
●Mounting cutout 68 x 33 mm (2.7 x 1.3˝)
●Storage of the minimum and maximum
recorded temperature until the system is reset
Configuration:
Panel, temperature indicator and thermostat,
identification strip.
Color Part No. DK
RAL 7035 (light gray) 7109.035
Accessories For Climate Control
Regulation/control
104 Climate Control
B
4.1
Accessories For Climate Control
Enclosure internal thermostat
Ideal for controlling filter fan units, heaters and
heat exchangers, this thermostat can also be
used as a signal generator for monitoring the
enclosure internal temperature.
Technical specifications:
●Bi-metal sensor as a temperature-sensitive
element with thermal feedback
●Contact population: Single-pole change-over
contact as a quick-break contact
●Permissible contact load:
Category 5 – 3 (heating)
AC 10 (4)1) A,
DC = 30 W
Category 5 – 4 (cooling)
AC 5 (4)1) A,
DC = 30 W
(1)) = Inductive load at cos ϕ = 0.6
●Setting range +5°C to +60°C (41°F to 140°F)
●Weight approximately 105 grams (3.7 oz)
●Dimensions 71 x 71 x 33 mm (2.8 x 2.8 x 1.3˝)
●Switching difference approximately 1 K ± 0.8 K
●A broad voltage spectrum, just one model
covers 24 to 230 V.
●Time-saving connection technique using a
terminal strip with a screw connection from the
outside.
●Flexible mounting on a vertical or horizontal
35 mm (1.4˝) support rail to EN 50 022, and
snap fastening in the TS/ES enclosure section
using the supplied adaptor.
Voltage Part No. SK
230/115/60/48/24 V (AC) 3110.000
60/48/24 V (DC)
Hygrostat
The hygrostat switches on the heater and/or fan
when a preset relative humidity level in the enclo-
sure is exceeded. The relative humidity is raised
above the dew point, and condensation on
assemblies or electronic components is avoided.
Technical specifications:
●Contact population: Single-pole change-over
contact as a quick-break contact
●Permissible contact load:
AC ~ 5 (0.2)1) A
DC = maximum 20 W
(1)) = Inductive load at cos ϕ = 0.6
●Setting range 50 – 100 % relative humidity
●Weight approximately 100 g (3.5 oz)
●Dimensions 71 x 71 x 33.5 mm (2.8 x 2.8 x 1.3˝)
●Switching difference approximately 4 %
●A broad voltage spectrum, just one model
covers 24 to 230 V.
●Time-saving connection technique using a
terminal strip with a screw connection from the
outside.
●Flexible mounting on a vertical or horizontal
35 mm (1.4˝) support rail to EN 50 022, and
snap fastening in the TS/ES enclosure section
using the supplied adaptor.
Voltage Part No. SK
24 – 230 V (AC/DC) 3118.000
Bottom-mounted adaptor
For enclosure internal thermostat SK 3110.000
and hygrostat SK 3118.000
Bottom-mounted adaptor with mounting option for
screwed cable glands, for targeted cable infeed
from appropriate equipment such as SK filter fan
units and enclosure heaters. In conjunction with
screwed cable glands, it is also suitable for use
as strain relief.
PU Part No. SK
13110.200
Regulation/control
Accessories For Climate Control
105Climate Control
B
4.1
Accessories For Climate Control
Speed control
Temperature dependent speed control for Rittal
filter fan units and air/air heat exchangers with a
voltage of 230 V AC, for noise reduction and to
save energy in part-load operation.
Technical specifications:
●For mounting on a 35 mm (1.4˝) support rail
EN 50 022
●Dimensions (H x W x D):
57 x 94 x 180 mm (2.4 x 3.7 x 7.1˝)
●Voltage:
230 V (AC)/115 V (AC)
●Setting range: +20°C to +55°C (68°F to 131°)
●Phase cross-over with microcontroller
●Maximum fan output 250 W or 1.2 A
at 230 V (AC)
●Maximum fan output 100 W or 1.2 A
at 115 V (AC)
Configuration:
Speed control, built into a PK enclosure 9512.100,
NTC sensor, length 1.80 m (71˝).
Voltage Part No. SK
230 V (AC) 3120.000
115 V (AC) 3120.1151)
1) Delivery times available on request.
Mounting adaptor
For speed control
The mounting adaptor enables direct attachment
of the speed control SK 3120.000/.115 to the verti-
cal frame sections of network enclosures.
Material:
Sheet steel, zinc-plated, passivated.
Configuration:
Mounting adaptor including assembly parts.
PU Part No. DK
1 set 7526.964
Interface card
For TopTherm air conditioners with comfort
controller
The interface card is an extension for TopTherm
air conditioners with comfort controller. In this way
it is possible, to monitor a master/slave combina-
tion of up to 10 air conditioners. Control is achiev-
ed by standardized interfaces: RS232 (DB9) or
RS 485, one PLC interface (DB9).
RS 422 (RJ 45 jack) is the connection to the Rittal
CMC-TC. Remote monitoring by TCP-IP, graphi-
cal interfaces for operation, evaluation and con-
trol, documentation, connection to additional sen-
sors for access control, monitoring is therefore
possible. The extension card is built into a 1 U
plastic housing. A voltage supply of 24 V DC is
needed. This may be supplied from the CMC-TC
by a wide-range power pack DK 7320.425 (100 to
240 V AC, 50/60 Hz) or externally by a Kycon con-
nector.
Configuration:
Interface card integrated into a plastic box
H x W x D mm (inches):
44 or 1 U x 136 x 129 (1.7 or 1 U x 5.4 x 5.1).
Serial SUB-D cable, 1.5 m (59˝).
PU Part No. SK
13124.200
Accessories For Climate Control
Regulation/control
106 Climate Control
B
4.1
Accessories For Climate Control
SK bus system
The SK bus system facilitates communications
between several enclosure air conditioners, Top-
Therm .500/.510/.540, production date 05/02 or
later, by a master/slave construction such as that
required in complex bayed enclosure systems for
optimum operating results.
Technical specifications:
The master/slave construction facilitates common
activation and deactivation by door limit switches,
parallel activation and deactivation by a
temperature setpoint, and common collective fault
signals and temperature logging, thereby
eliminating the need for intricate wiring.
Configuration:
3 m (118˝) shielded interface cable, including
operating manual on programming the air condi-
tioners.
Note:
nB = nK – 1
nB: Number of order units (SK bus system)
nK: Number of air conditioners to be linked
Property rights:
German patent no. 196 15 469
35°C
30°C
25°C
20°C
20°C
40°C
35°C
For Part No. SK
TopTherm 3124.100
Climate controlled
enclosures 3124.000
Cable connection kit
For CS outdoor air conditioners
For simple connection of CS air conditioners.
All cables preassembled with the corresponding
connectors.
Length of cables approximately 2500 mm (98˝).
Configuration:
1 set = 3 cables for AC,
door operated switch and
alarm connection.
PU Part No. CS
1 set 9765.105
Cable connection kit
For CS outdoor heat exchangers
For simple connection of CS heat exchangers.
All cables preassembled with the corresponding
connectors.
Length of cables approximately 2500 mm (98˝).
Option Part No. CS
3 cables for AC/DC and
alarm connection 9765.110
2 cables for AC/DC and
alarm connection 9765.115
Test adaptor
For CS outdoor climate control equipment
The 9-pole sub-D interface allows testing of all
CS climate control equipment. Alternatively sup-
ports automatic or manual test procedures.
Configuration:
1 set = test adaptor
including 2 m (78.7˝) connection cable.
PU Part No. CS
1 set 9765.050
General
Accessories For Climate Control
107Climate Control
B
4.1
Accessories For Climate Control
Roof plates TS
For mounting on:
●TopTherm roof-mounted air conditioners
●TopTherm roof-mounted fan
●Vent attachment TS
The cutouts in the roof plate are arranged in such
a way that the TopTherm roof-mounted air condi-
tioners are positioned centrally on the enclosure.
Material:
Sheet steel
Configuration:
Assembly parts.
Color:
RAL 7035 (light gray)
13
T1
B1
T2 T3
B2 =
=
For modular
enclosures
W x D
mm (inches)
To fit the
mounting of
TopTherm
Part No.
TS
600 x 600 (23.6 x 23.6) SK 3382. . . . 8801.3001)
800 x 600 (31.5 x 23.6) 8801.320
600 x 600 (23.6 x 23.6) SK 3273.5 . .
SK 3383. . . .
SK 3384. . . .
SK 3385. . . .
8801.3101)
800 x 600 (31.5 x 23.6) 8801.330
1200 x 600 (47.2 x 23.6) 8801.350
800 x 600 (31.5 x 23.6) SK 3386. . . .
SK 3387. . . .
8801.3402)
1200 x 600 (47.2 x 23.6) 8801.360
1) When mounting the air conditioners, there may be a
collision with the eyebolts of the enclosure; for this
reason roof fastening screws are supplied loose with
the roof plates.
2) Attachment is from the inside using metal brackets and
retaining clamps.
For mounting TopTherm Dimensions in mm (inches) Part No. TS
B1 B2 T2 T3
SK 3382. . . . 567.5 (22.3) 475 (18.7) 260 (10.2) 129.3 (5.1) 8801.300
SK 3382. . . . 767.5 (30.2) 475 (18.7) 260 (10.2) 129.3 (5.1) 8801.320
SK 3383. . . ./SK 3384. . . ./SK 3385. . . . 567.5 (22.3) 490 (19.3) 390 (15.4) 61.3 (2.4) 8801.310
SK 3383. . . ./SK 3384. . . ./SK 3385. . . . 767.5 (30.2) 490 (19.3) 390 (15.4) 61.3 (2.4) 8801.330
SK 3383. . . ./SK 3384. . . ./SK 3385.XXX 1167.5 (46.0) 490 (19.3) 390 (15.4) 61.3 (2.4) 8801.350
SK 3386. . . ./SK 3387. . . . 767.5 (30.2) 692 (27.2) 392 (15.4) 57.8 (2.8) 8801.340
SK 3386. . . ./SK 3387. . . . 1167.5 (46.0) 692 (27.2) 392 (15.4) 57.8 (2.8) 8801.360
T1 for all models is 567.5 mm (22.3˝)
B = Width
T = Depth
Vent attachment TS
For passive ventilation with labyrinthine air flow
routing, to match the roofs for TopTherm roof-
mounted air conditioners.
Color:
RAL 7035 (light gray)
Rating:
IP 43
Configuration:
Assembly parts.
37.5
495
595
For roof plates
with cutout
mm (inches) Part No. TS
490 x 390 (19.3 x 15.4) 8801.380
Trim frame
For slimline air conditioners
Slimline air conditioners can be internally or exter-
nally mounted on an enclosure door or wall. The
trim frame presents a closed front for the air con-
ditioner.
Material:
Sheet steel
Color:
RAL 7035
90
For air conditioner Part No. SK
SK 3366. . . .
SK 3377. . . . 3377.000
Accessories For Climate Control
General
108 Climate Control
B
4.1
Accessories For Climate Control
Quick-change frame
For TopTherm roof-mounted air conditioners
The quick-change frame is more than just an
alternative to the standard air conditioner frame.
Combined with the seal, the lower part of the
frame is screw-fastened to the enclosure. This
allows the plug-in air conditioner to be attached or
removed from the top part of the quick-change
frame that was previously mounted on the air con-
ditioner using quick-release fasteners. In case of
servicing, this means minimal assembly time and
minimal downtime. The quick-change frame offers
effective protection against the ingress of oil into
the enclosure in oily atmospheres, due to its inte-
grated drainage trough.
Material:
Sheet steel
Color:
RAL 7035 (light gray)
Configuration:
Quick-change frame, seal,
quick-release fasteners.
Property rights:
German patent no. 41 10 323
French Patent no. 2 675 317
GB patent no. 2 254 735
For
TopTherm air conditioner Part No.
SK
SK 3382. . . . 3286.700
SK 3383. . . .
SK 3384. . . .
SK 3385. . . . 3286.800
SK 3386. . . .
SK 3387. . . . 3286.900
Electronic condensate
evaporator
For external mounting on enclosures.
For use with all enclosure air conditioners and
air/water heat exchangers.
Evaporation performance:
1) 2.4 l/d (0.6 gal/d)
2) 4.2 l/d (1.1 gal/d)
Color:
RAL 7035 (light gray)
Configuration:
Electronic condensate evaporator,
ready for connection.
Detailed drawing,
see page 139.
Voltage
in V, Hz
Part No. SK
For
SK 3302/
SK 3303
For
400 mm (15.7˝)
wide
air conditioners
230 V, 50/60 Hz 3301.5601) 3301.5702)
115 V, 50/60 Hz 3301.5801) 3301.5902)
Condensate collecting bottle
For mounting on the enclosure.
For use with all enclosure air conditioners and
air/water heat exchangers.
Safety overflow at the side.
Capacity approximately 0.75 l (0.2 gal).
Condensate discharge tube
Membrane grommet
Maximum 70 mm (2.8˝)
Configuration:
Condensate collecting bottle, bottle holder includ-
ing assembly parts.
1
2
3
Ø 73
239
66
1
2
3
PU Part No. SK
13301.600
Condensate hose
For removing and forwarding condensate. For
connecting to enclosure air conditioners.
Material:
PVC, transparent
Configuration:
10 m (394˝) hose.
For devices
Material
thickness
Ø
Part No.
SK
SK 3302. . . ./SK 320. . . . . 8 x 1.5 mm
(0.06˝) 3301.608
SK 3303. . . ./SK 3361. . . . 10 x 1.5 mm
(0.06˝) 3301.610
SK 3273. . . ./SK 3304. . . ./
SK 3305. . . ./SK 3328. . . ./
SK 3329. . . ./SK 3332. . . ./
SK 3366. . . ./SK 3359. . . ./
SK 3382. . . ./SK 3383. . . ./
SK 3384. . . ./SK 3385. . . ./
SK 3386. . . ./SK 3387. . . ./
SK 3377. . . .
12 x 2 mm
(0.08˝) 3301.612
General
Accessories For Climate Control
109Climate Control
B
4.1
Accessories For Climate Control
Integrated louvers
For ventilation by convection; easily retrofitted
using 4 screws.
Material:
Sheet steel
Color:
RAL 7035 (light gray)
Detailed drawing,
see page 139.
B
H
T
H
mm
(inches)
W
mm
(inches)
D
mm
(inches)
PU Part No.
SK
110 (4.3) 160 (6.3) 8 (0.3) 4 2541.235
100 (3.9) 210 (8.3) 8 (0.3) 4 2542.235
110 (4.3) 330 (13.0) 8 (0.3) 4 2543.235
For RAL 7032 (pepple gray), use order extension .200;
to order primed version, use extension .300.
Delivery times available on request.
Outlet filter
For ventilation by convection, an outlet filter can
be installed in the upper and lower sections of the
modular enclosure.
Material:
ABS,
material resistance to UL 94-V0.
Color:
RAL 7035 (light gray)
Configuration:
Outlet filter including filter mat. Note:
EMC version,
see page 83.
Accessories:
Spare filter mats.
Fine filter mats.
Dimensions
in mm (inches) Part No.
SK
116 x 22 (4.6 x 0.9) 3321.207
148 x 24.5 (5.9 x 1.0) 3322.207
204 x 30 (8.0 x 1.2) 3323.207
255 x 30 (10.0 x 1.2) 3325.207
323 x 30 (12.7 x 1.2) 3326.207
For RAL 7032 (pebble gray), use order extension .200.
Hose-proof hoods
For filter fan units/outlet filters
When the hose-proof hood is mounted above the
filter fan unit and outlet filter in conjunction with
a fine filter mat, a rating of IP 56 (NEMA 3R) to
EN 60 529/10.91 is achieved. Particularly suitable
for use in the food industry.
Material:
Stainless steel
Rating:
In conjunction with the filter fan units/outlet
filters, NEMA 3R + 12 is met.
For Dimensions
in mm (inches) Part No.
SK
SK 3321. . . . 260 x 150 x 40
(10.2 x 5.9 x 1.6) 3321.8001)
SK 3322. . . . 270 x 176 x 55
(10.6 x 6.9 x 2.2) 3322.800
SK 3323. . . . 410 x 233 x 55
(16.1 x 9.2 x 2.2) 3323.800
SK 3324. . . .
SK 3325. . . .
500 x 282 x 85
(19.7 x 11.1 x 3.3) 3324.800
SK 3326. . . .
SK 3327. . . .
560 x 350 x 110
(22.0 x 13.8 x 4.3) 3326.800
1) Delivery times available on request.
B = Width
T = Depth
Accessories For Climate Control
General
110 Climate Control
B
4.1
Accessories For Climate Control
Front outlet grille 2U
For centrifugal fans
This front outlet grille is required if a 482.6 mm (19˝)
cross-flow blower (SK 3144.000/SK 3145.000) is
used in the lower section of the electronic enclo-
sure and the hot air is to be expelled to the outside
from the upper section of the enclosure. The
design of the grille matches that of the intake
grille in the cross-flow blower. These grilles can
also be used as simple inflow and outflow grilles
with natural convection.
Accessories:
Filter mat.
PU Part No. SK
13176.000
Filter holder
For roof ventilation
The use of a filter mat is required in order to
increase the ratings of the roof vent
(SK 3148.000).
Ratings IP 43 to EN 60 529/10.91 is achieved.
Material:
Sheet steel
Configuration:
Filter holder including filter mat.
Accessories:
Spare filter mat.
H x W x D
mm (inches) Part No. SK
244 x 340 x 15 (9.6 x 13.4 x 0.6) 3175.000
Bypass safety valve
For use with chiller systems and air/water heat
exchangers.
Material:
Brass
Option PU Part No. SK
1/2˝_619_E bypass valve 1 3301.900
3/4˝_619_E bypass valve 1 3301.910
1˝_619_E bypass valve 1 3301.920
Flow regulator valve
For use with air/water heat exchangers. Espe-
cially if more than one heat exchanger (n > 1) is
used in the water cooling circuit.
Material:
Brass
Option PU Part No. SK
3/4˝ x 1/2˝
flow regulator valve 13301.930
3/4˝ x 3/4˝
flow regulator valve 13301.940
Filter mats
Accessories For Climate Control
111Climate Control
B
4.1
Accessories For Climate Control
Additives for chiller systems
Configuration:
10 l (2.2 gal) canister.
Rifrost Anti freeze
water mixture Part No. SK
Outdoor 1 : 2 3301.950
Standard 1 : 4 3301.960
Filter mats
Rittal air conditioners are low-maintenance and
are supplied without filter mats. Filter mats may be
used for extreme conditions.
Material:
Open celled polyurethane foamed plastic with
excellent physical and mechanical properties.
Temperature resistant from –40°C to +80°C
(–40°F to 176°F). Thickness: 10 mm (3.9˝).
For TopTherm air conditioners
For air conditioner H x W x D
mm (inches) PU Part No. SK
SK 3302.300/SK 3302.310 95 x 190 x 10 (3.7 x 7.5 x 0.4) 3 3286.110
SK 3302. . . ./SK 3303. . . ./SK 3361. . . . 200 x 265 x 10 (7.9 x 10.4 x 0.4) 3 3286.300
SK 3304. . . ./SK 3305. . . ./SK 3328. . . ./SK 3329. . . ./
SK 3332. . . ./SK 3366. . . . 268 x 344 x 10 (10.6 x 13.5 x 0.4) 3 3286.400
SK 3273. . . ./SK 3382. . . ./SK 3383. . . ./SK 3384. . . ./
SK 3385. . . ./SK 3359. . . . 255 x 530 x 10 (10.0 x 20.9 x 0.4) 3 3286.500
SK 3386. . . ./SK 3387. . . . 300 x 720 x 10 (11.8 x 28.3 x 0.4) 3 3286.600
SK 3377. . . . 210 x 205 x 10 (8.3 x 8.1 x 0.4) 3 3253.010
For discontinued air conditioners
For air conditioner H x W x D
mm (inches) PU Part No. SK
SK 3296. . . ./SK 3272.100/SK 3290. . . ./SK 3280.100/
SK 3299. . . ./SK 3261. . . . 332 x 539 x 10 (13.1 x 21.2 x 0.4) 3 3286.100
SK 3265.100/SK 3266.100 332 x 270 x 10 (13.1 x 10.6 x 0.4) 3 3267.100
SK 3256. . . . 300 x 395 x 10 (11.8 x 15.6 x 0.4) 3 3254.000
SK 3293. . . ./SK 3281.100/SK 3298. . . ./SK 3279.100/
SK 3260. . . ./SK 3269. . . ./SK 3262.100/SK 3393. . . ./
SK 3381.100/SK 3391. . . .
313 x 334 x 10 (12.3 x 12.3 x 0.4) 3 3294.100
SK 3255. . . ./SK 3395. . . . 245 x 350 x 10 (9.6 x 13.8 x 0.4) 3 3253.000
SK 3394. . . . 200 x 315 x 10 (7.9 x 12.4 x 0.4) 3 3285.000
SK 3292.134/SK 3278.134 250 x 325 x 10 (9.8 x 12.7 x 0.4) 3 3286.000
Filter mats
Made of chopped-fiber mat with a progressive
structure. Temperature resistant to 100°C (212 °F),
self-extinguishing category F1 to DIN 53 438.
Dust-laden air side: Open structure.
Clean air end: Closed structure.
Reliable filtering of virtually all types of dust from a
particle size of 10 µm.
Material:
Chemical fiber
For centrifugal fans/front outlet grilles 2U H x W x D
mm (inches) PU Part No. SK
SK 3144.000/SK 3145.000/SK 3176.000 85 x 425 x 8
(3.3 x 16.7 x 0.3) 53177.000
Accessories For Climate Control
Filter mats
112 Climate Control
B
4.1
Accessories For Climate Control
Metal filter
When air conditioners are used in dusty and
damp environments, it is advisable to use washa-
ble metal filters. If air or steam condenses on the
metal surfaces, any particles that may be present
will adhere to the metal and are easily washed out
with water or grease-dissolving detergents.
Material:
Aluminum
Thickness: 10 mm (0.4˝)
For TopTherm air conditioners
For air conditioner H x W x D
mm (inches) PU Part No. SK
SK 3302.300/SK 3302.310 95 x 190 x 10 (3.7 x 7.5 x 0.4) 1 3286.120
SK 3302.100/SK 3302.110/SK 3303. . . ./SK 3361. . . . 200 x 265 x 10 (7.9 x 10.4 x 0.4) 1 3286.310
SK 3304. . . ./SK 3305. . . ./SK 3328. . . ./SK 3329. . . ./
SK 3332. . . ./SK 3366. . . . 288 x 344 x 10 (11.3 x 13.5 x 0.4) 1 3286.410
SK 3273. . . ./SK 3382. . . ./SK 3383. . . ./SK 3384. . . ./
SK 3385. . . ./SK 3359. . . . 255 x 530 x 10 (10.0 x 20.9 x 0.4) 1 3286.510
SK 3386. . . ./SK 3387. . . . 300 x 720 x 10 (11.8 x 28.3 x 0.4) 1 3286.610
SK 3377. . . . 210 x 205 x 10 (8.3 x 8.1 x 0.4) 1 3253.220
For discontinued air conditioners
For air conditioner H x W x D
mm (inches) PU Part No. SK
SK 3296. . . ./SK 3272.100/SK 3290. . . ./SK 3280.100 290 x 520 x 10 (11.4 x 21.3 x 0.4) 1 3286.210
SK 3299. . . ./SK 3261. . . . 315 x 520 x 10 (12.4 x 21.3 x 0.4) 1 3286.200
SK 3265.100/SK 3266.100 320 x 265 x 10 (12.6 x 10.4 x 0.4) 1 3267.200
SK 3256. . . . 365 x 315 x 10 (14.3 x 12.4 x 0.4) 1 3254.200
SK 3293. . . ./SK 3281.100/SK 3298. . . ./SK 3279.100/
SK 3260. . . ./SK 3269. . . ./SK 3262.100/SK 3393. . . ./
SK 3381.100/SK 3391. . . .
300 x 328 x 10 (11.8 x 12.9 x 0.4) 1 3294.200
SK 3255. . . ./SK 3395. . . . 210 x 348 x 10 (8.7 x 13.7 x 0.4) 1 3253.200
SK 3394. . . . 415 x 375 x 10 (16.3 x 14.8 x 0.4) 1 3285.200
For climate control doors
For climate control door H x W x D
mm (inches) PU Part No. SK
SK 3306. . . ./SK 3307. . . ./SK 3309. . . ./SK 3310. . . . 100 x 424 x 10 (3.9 x 16.7 x 0.4) 1 3284.200
SK 3308. . . . 100 x 624 x 10 (3.9 x 24.6 x 0.4) 1 3288.200
SK 3331. . . . 150 x 380 x 10 (5.9 x 15.0 x 0.4) 1 3289.200
For Mini chiller systems
For chiller systems H x W x D
mm (inches) PU Part No. SK
SK 3318.600/SK 3318.610/SK 3319.600/SK 3319.610 255 x 530 x 10 (10.0 x 20.9 x 0.4) 1 3286.510
SK 3320.600/SK 3334.600 558 x 500 x 8 (22.0 x 19.7 x 0.3) 1 3286.520
SK 3360. . . . 268 x 344 x 10 (10.6 x 13.5 x 0.4) 1 3286.410
Filter mats
Accessories For Climate Control
113Climate Control
B
4.1
Accessories For Climate Control
Spare filter mats
Made of chopped-fiber mat with a progressive
structure.
Temperature resistant to 100°C (212°F),
self-extinguishing
category F1 to DIN 53 438.
Dust-laden air side: Open structure.
Clean air end: Closed structure.
Reliable filtering of virtually all types of dust from a
particle size of 10 µm.
Material:
Chemical fiber
For filter fan units
For filter fan units H x W x D
mm (inches) PU Part No. SK
SK 3321. . . . 89 x 89 x 10 (3.5 x 3.5 x 0.4) 5 3321.700
SK 3322. . . . 120 x 120 x 12 ((4.7 x 4.7 x 0.5) 5 3322.700
SK 3323. . . . 173 x 173 x 17 (6.8 x 6.8 x 0.7) 5 3171.100
SK 3324. . . ./SK 3325. . . . 221 x 221 x 17 (8.7 x 8.7 x 0.7) 5 3172.100
SK 3326. . . . 289 x 289 x 17 (11.4 x 11.4 x 0.7) 5 3173.100
SK 3327. . . . 289 x 289 x 10 (11.4 x 11.4 x 0.4) 5 3327.700
For filter holders
For filter holders H x W x D
mm (inches) PU Part No. SK
SK 3175.000 242 x 338 x 20 (9.5 x13.3 x 0.8) 3 3174.000
Fine filter mats
Made of chopped-fiber mat with a progressive
structure.
Temperature-resistant to 100°C (212°F),
self-extinguishing category F1 to DIN 53 438.
Dust-laden air side: Open structure.
Clean air end: Closed structure.
Reliable filtering of virtually all types of dust from a
particle size of 10 µm.
Material:
Chemical fiber
For filter fan units/outlet filters
For filter fan units/outlet filters H x W x D
mm (inches) PU Part No. SK
SK 3323. . . . 173 x 173 x 12 (6.8 x 6.8 x 0.5) 5 3181.100
SK 3324. . . ./SK 3325. . . . 221 x 221 x 12 (8.7 x 8.7 x 0.4) 5 3182.100
SK 3326. . . ./SK 3327. . . . 289 x 289 x 12 (11.4 x 11.4 x 0.5) 5 3183.100
114 Climate Control
Liquid Cooling
Features
B
4.1
Liquid Cooling
From passive air climate control to active liquid cooling of
high-performance CPUs, Rittal provides all the required com-
ponents and systems, designed to your requirements.
Software-assisted planning and calculation of requirements,
together with modular, rack-compatible technology, help to
minimize investment costs, thereby offering a future safe
solution with a high degree of flexibility.
Liquid cooling package
T1
T2
B1
H1
B2
H2
Modular, upgradeable and tem-
perature neutral cooling con-
cept. 12 kW (40,982 BTU) cool-
ing capacity, with three cooling
modules supported per cooling
rack.
Optimized air routing
Cold air is blown in at the sides,
so that the cold air is evenly dis-
tributed in front of the 482.6 mm
(19˝) level.
Optionally 1 or 2 server racks
may be cooled – both stand-
alone and bayed sitings are
possible. Bayable to TS and PS
server racks, even retroactively.
Rack-mounted chiller system
Microcontroller control Liquid-cooled computers
In a 482.6 mm (19˝) server rack
are supplied by the shortest
route by six cooling circuits,
without the need for an addi-
tional rising main.
Vibration-free installation
Cooling circuit distributor for processor climate control
The distribution pipes for inlet
and return lines for targeted, reli-
able liquid cooling may be inte-
grated into all standard rack sys-
tems.
Cooling circuit distributor kit
Blade server
The 482.6 mm (19˝) distributors
are connected to the rising
main.
Cooling circuit distributor
482.6 mm (19˝)
Connections for 10 servers and
a main connection to the verti-
cal rising main.
Rittal liquid cooling package
Cooling
115Climate Control
B
4.1
Cooling
T1
T2
B1
H1
B2
H2
B = Width
T = Depth
Modular, upgradeable and tem-
perature neutral cooling
concept.
●Maximum cooling capacity
12 kW (40,982 BTU), with
three cooling modules possi-
ble per cooling rack
●Approximate cooling capac-
ity 4 kW (13,661 BTU) per
cooling module at 800 m3/h
(471 cfm) air displacement
●Optimized air routing: Cold air
is blown in at the sides, so
that the cold air is evenly
distributed in front of the
482.6 mm (19˝) level
●Optionally 1 or 2 server racks
may be cooled – stand-alone
and bayed siting possible
●Bayable to TS and PS server
racks, even retroactively
●Active condensate handling
●Optional control and
monitoring1) of the cooling
rack via Rittal CMC-TC
●Two-piece modules; for easy
installation in narrow passage-
ways
Technical specifications:
●Mounted as a cooling rack on
a server rack based on TS8
modular enclosure, with
H = 2000 mm (78.7˝),
D = 1000 mm (39.4˝).
●Each cooling rack can
accommodate a maximum of
three air/water heat
exchanger cooling modules.
●Standard supply: Cooling rack
equipped with one cooling
module.
●Individual modules upgrad-
eable to full installation by
quick-release couplings.
●Controlled by a separate
module which may be con-
nected to the CMC-TC for
incorporation into the network
(monitoring).
●Condensation management:
The pump in the condensate
tray pumps any condensation
into the return section of the
cooling circuit.
For professional installation of the heat exchanger, where possible, the enclosures being cooled should be sealed against the ingress of ambient air:
Enclosure + 3 modules
Individual module for 230 V/115 V
Part No. SK 3301.230 3301.210 3301.250
Voltage V, Hz 230, 50/60 115, 50/60 230, 50/60
Dimensions in mm (inches)
H
B
T
2000 (78.7)
300 (11.8)
1000 (39.4)
550 (21.7)
250 (9.8)
950 (37.4)
Useful cooling capacity at 15°C (59°F) water inlet,
15 l/min (4 gal/min), 20°C (68°F) cold air in W/BTU 4000/3500 (13,661/11,953)
Rated current maximum 1.8 A
Pre-fuse T 5.0 A
Cooling medium Water (specifications may be found on the Internet)
Water inlet temperature +5°C to +30°C (41°F to 86°F)
Permissible operating pressure p. maximum 2 to 8 bar (29 to 116 psi)
Temperature range +5°C to +40°C (41°F to 104°F)
Ratings to EN 60 529/10.91 IP 30 –
Duty cycle 100 %
Type of connection Current: Connection cable with earthing-pin plug: Water: 3/4˝ quick-release fastener
Weight in kg (lb) Maximum 160 (352.7) Approximately 25 (55.1)
Color RAL 7035 (light gray)
Air displacement of fans Maximum 2400/2100 m3/h (1413/1236 cfm) 800/700 m3/h (471/412 cfm)
Temperature control Electronically controlled magnetic valve and 4-way fan control
1) Flow, leakage, inlet/return, intake/exhaust temperature.
The general remarks on air/water heat exchangers apply; (available on the Internet, log onto www.rittal-corp.com).
Description Dimensions in mm (inches) PU Part No. Description Dimensions in mm (inches) PU Part No.
Sidewall, screw-fastened H x D 2000 x 1000 (78.7 x 39.4) 2 8100.235 Divided partitioning plate
for retrofitted sealing
in the base area
W x D
600 x 1000 (23.6 x 39.4) 1 7825.300
Viewing door H x W 2000 x 600 (78.7 x 23.6) 1 8610.6002) 800 x 1000 (31.5 x 39.4) 1 7825.302
2000 x 800 (78.7 x 31.5) 1 8610.8002) Divided roof plate
for cable entry W x D 600 x 1000 (23.6 x 39.4) 1 7826.6053)
Sheet steel door, solid H x W
2000 x 600 (78.7 x 23.6) 1 7824.2052) 800 x 1000 (31.5 x 39.4) 1 7826.8053)
2000 x 800 (78.7 x 31.5) 1 7824.2072) Sealing kit for two-sided
cooling when bayed
1
set 7825.305
2) Alternatively: Sealing kit
for vented sheet steel doors
H x W 2000 x 600 (78.7 x 23.6) 1 7824.185
3) Retro-fitting is not possible.
H x W 2000 x 800 (78.7 x 31.5) 1 7824.187
Accessories Page 100 Chiller systems From page 48
Cooling
Rack-mounted chiller system
116 Climate Control
B
4.1
Cooling
H
B
T
B = Width
T = Depth
Liquid-cooled computers in a
482.6 mm (19˝) server rack are
supplied by the shortest route
by six cooling circuits, without
an additional rising main.
●Partial liquid cooling in
diverse environments
●Combination of air and liquid
cooling possible
Technical specifications:
●Installation in the 482.6 mm
(19˝) level of the enclosure
●6 cooling circuit connections
for server/CPU cooling on the
back of the chiller via drip-free
quick-release couplings
●Vibration-free installation
●2 freely programmable alarm
outputs
●Operating pressure display
●Optional automatic bypass
Also required:
●Quick-release couplings
●Heat sink, retaining clamps
●Hose,
see page 118.
Part No. SK 3301.260
Voltage V, Hz 230, 50/60
Dimensions in mm (inches)
H
B
T
175 (6.9)
442 (17.4)
751 (29.6) + 100 mm (3.9˝) for water connections
Cooling capacity at
Tw = 25°C (77°F)
Tu = 32°C (89.6°F),
2 l/h (0.5 gal/h) in W (BTU)
1000/1070 (3415/3654)
Power consumption 640/790 W
Rated current maximum 4.5 A
Refrigerant R134a, 550 g
Pmax. cooling circuit 25 bar (363 psi)
Temperature range Environment +10°C to +40°C (50°F to 104°F)
Liquid media +10°C to +35°C (50°F to 95°F)
Pump capacity 4 l/min (1.1 gal/min) 2 bar (29 psi)
Tank Pressure-sealed
Tank capacity –
Water connections Quick-release coupling, drip-free
Weight in kg (lb) 45 (99.2)
Color Textured RAL 7035 (light gray)
Ratings (electric) IP 20
Air displacement of fans 450 m3/h (265 cfm)
Temperature control Microcontroller, setting range +10°C to +30°C (50°F to 86°F) (factory setting +18°C (64°F))
Delivery times available on request.
Accessories Page 100 Chiller systems From page 48
Power Cooling System PCS
Cooling
117Climate Control
B
4.1
Cooling
Cooling manifold for racks
Water cooling
High performance for CPUs, power packs and
disk drives by cooling directly at the area where
heat is generated. The manifold pipes for inlet
and return lines for targeted, reliable liquid cool-
ing may be integrated into all standard rack sys-
tems.
They are linked to an external, central air condi-
tioner which also controls the inlet temperature.
The drip-free quick-release coupling ensures an
extremely high level of operational reliability. Moni-
toring of the systems function is performed by the
Rittal CMC-TC module.
There are 2 complete basic packages available
for retrofitting for different enclosure heights.
Configuration:
Package 1
Water intake:
Connection system, non-return valve and 10 m
(394˝) hose, 1/2˝, fittings, filter, vent valve.
Water distribution:
Cooling circuit distributor for 20 CPU cooling
circuits, vent valve, 40 bulkhead couplings, 50 m
(1969˝ or 10.9 yards) distributor hose, 6 mm
(0.2˝).
Package 2
Water intake:
Connection system, non-return valve and 10 m
(394˝) hose, 1/2˝, fittings, filter, vent valve.
Water distribution:
Cooling circuit distributor for 40 CPU cooling
circuits, vent valve, 80 bulkhead couplings, 100 m
(3937˝or 109 yards) distributor hose, 6 mm (0.2˝).
Also required:
Chiller system,
see page 50 onwards.
Accessories:
Manifold accessories.
For modular
enclosure height Part No. SK
mm (inches) U Package 1 Package 2
1200 (47.2) 24 3301.810 –
2000 (78.7) 42 – 3301.820
Cooling circuit manifold kit
For blade server
Our liquid cooling for server racks serves as a
basis for this solution. The large number of drip
free taps to the individual computer is now
replaced by the connection of horizontal liquid
subdistributors, where the drip-free connectors for
connection of the Powerblade are found. 5 units
are possible with 7U per server and 1 per
482.6 mm (19˝) distributor. The individual
482.6 mm (19˝) distributors are connected to the
rising main with drip-free connectors, so that the
system is modular and scaleable.
Configuration:
1 vertical rising main with 5 taps,
1 482.6 mm (19˝) cooling circuit distributor with
10 inlet and return connections,
1 connection hose (inlet and return) from the
482.6 mm (19˝) cooling circuit distributor to the
vertical rising main,
1 connection hose (inlet and return) from the
vertical rising main to the chiller.
Also required:
Chiller system,
see page 50 onwards.
Accessories:
482.6 mm (19˝) distributor,
distributor accessories.
PU Part No. SK
13301.280
Cooling
Power Cooling System PCS
118 Climate Control
B
4.1
Cooling
Cooling circuit manifold 19˝
For installation in the 482.6 mm (19˝) level with
drip-free connections for 10 servers and a main
connection to the vertical rising main; 0.5 m
(19.7˝) hose in each case for the inlet and return. Accessories:
Manifold accessories.
PU Part No. SK
13301.270
Manifold accessories
Description PU Part No. SK
Heat sink 1 3301.000
Connector for heat sink 6 mm (0.23˝) 23301.010
4 mm (0.15˝) 23301.020
Retaining clamps
Athlon 1 3301.030
Opteron 1 3301.040
Xeon 1 3301.050
P 4 1 3301.060
Connection system for hose
(sold by the meter)
4 mm (0.15˝) 13301.070
6 mm (0.23˝) 13301.080
Screw-in coupling G 1/8˝ with seal 10 3301.090
Screw-in connector G 1/8˝ with seal 10 3301.130
Connector sleeve, 6 mm (0.23˝) 10 3301.160
Connector grommet, 6 mm (0.23˝) 10 3301.170
Straight screw-in connector G 1/8˝, 6 mm (0.23˝) 10 3301.180
Sealing plug, 6 mm (0.23˝) 10 3301.190
Y-adaptor, 6 to 2 x 4 mm (0.15˝) 10 3301.700
Water distribution:
2 x rising main 24U for TS8, vent valve, screw-in connector 1/2˝,
screw-in coupling 1/2˝
13301.710
Water distribution:
2 x rising main 42U for TS8, vent valve, screw-in connector 1/2˝,
screw-in coupling 1/2˝
13301.720
Water infeed:
2 x connector grommet 1/2˝, 2 x connector sleeve 1/2˝, hose 1/2˝ (10 m (394˝)),
non-return valve 1/2˝,
dirt trap (with 2 x 1/2˝ connector sleeve), screw-in connector 1/2˝
(on the air conditioner), screw-in coupling 1/2˝ (on the air conditioner),
6 x hose clamps 1/2˝
13301.730
Monitoring at the connection to the CMC:
Temperature sensor + clamping screw fastening 13301.740
Accessories/work materials
Hose cutter 1 3301.750
Thermally conductive paste 1 3301.760
Teflon sealing tape 1 3301.770
Sealing plug 1/4˝13301.780
Climate controlled enclosures
Climate Control
119Climate Control
C
4.
Climate Control
4.1 Climate controlled enclosures
Single-door, useful cooling capacity 1100/1500 W (3756/5123 BTU)
605
157
461
80
512
31
1
1800 (2000)
797
min. 100
157
605
661
80
712
31
1
1800 (2000)
597
min. 100
1100 W (3756 BTU) 1500 W (5123 BTU)
max. installation depth =
478 mm (18.8˝)
1 max. installation depth =
478 mm (18.8˝)
1
Two-door, useful cooling capacity 2000/2500 W (6830/8538 BTU)
461
80
T2
1800/2000
1197
T1
1197
1800/2000
461
80
T2
T1
900250
Device position
left
Device position
right
686.5
2000 W (6830 BTU) 2500 W (8538 BTU)
D (T1) max. 445 (17.5) 415 (16.3)
D (T2) 190 (7.5) 220 (8.7)
min.100
min.100
Climate Control
Climate control doors
120 Climate Control
C
4.
Climate Control
1777.5 (1977.5)
592
1777.5 (1977.5)
592
4.1 Climate control doors
For installing in 600 mm (23.6˝) wide TS8 modular enclosures, useful cooling capacity 1100/1500 W (3756/5123 BTU)
For installing in 600 mm (23.6˝) wide TS8 modular enclosures, useful cooling capacity 2000/2500 W (6830/8538 BTU)
190
90
461
480
80
157
57
461
592
1777.5 (1977.5)
1777.5 (1977.5)
592
900
250
1100 W (3756 BTU) 1500 W (5123 BTU)
190
90
461
220
120
461
2000 W (6830 BTU) 2500 W (8538 BTU)
For installing in 800 mm (31.5˝) wide TS8 modular enclosures, useful cooling capacity 1500 W (5123 BTU)
480
80
157
57
661
1777.5 (1977.5)
792
592
1777.5 (1977.5)
1777.5 (1977.5)
592
For installing in 1200 mm (47.2˝) wide TS8 modular enclosures, useful cooling capacity 1100/1500 W (3756/5123 BTU)
For installing in 1200 mm (47.2˝) wide TS8 modular enclosures, useful cooling capacity 2000/2500 W (6830/8538 BTU)
900
250
1777.5 (1977.5)
592
220
120
461
190
90
461
1100 W (3756 BTU) 1500 W (5123 BTU)
1777.5 (1977.5)
592
157
57
461
190
90
461
2000 W (6830 BTU) 2500 W (8538 BTU)
Roof-mounted air conditioners
Climate Control
121Climate Control
C
4.
Climate Control
597
415
365
Ø 80
30
1
375
415
326
170
1
4.1 Roof-mounted air conditioners
Useful cooling capacity 500/750 W (1708/2561 BTU)
Mounting cutout
475
260
326
375
597
Condensate discharge 1/2˝, flexible
1
597
415
380
Ø 100
27
1
475
415
420
280
1
Useful cooling capacity 1000 W (3415 BTU)
Useful cooling capacity 1100 W (3756 BTU)
Useful cooling capacity 1500/2000 W (5123/6830 BTU)
Mounting cutout
490
597
420
390
475
Condensate discharge 1/2˝, flexible
1
470
796
538
Ø 150
38.5
1
580
238
Ø 150
1
Useful cooling capacity 3000/4000 W (10,246/13,661 BTU)
Mounting cutout
580
520
392
796
692
Condensate discharge 1/2˝, flexible
1
Climate Control
Wall-mounted air conditioners
122 Climate Control
C
4.
Climate Control
6
340
27
281
471
525
499
(483)
9
30°
10
517
525
4
25
25
Ø 7 (4x)
340
333 4
9
17
314
525
340
153 55
98
4.1 Wall-mounted air conditioners
Mini in horizontal format, useful cooling capacity 300 W (1025 BTU)
Mounting cutout
external mounting
Mounting cutout
internal mounting
External
mounting
Internal
mounting
280
550
140 42
98
Useful cooling capacity 300 W (1025 BTU)
280
550
501
251
18 x 45°
280
(230)
200
254
524
Ø 8 (4x)
Ø 15 (2x)
266
25
492
518
550
Mounting cutout
external mounting
Mounting cutout
internal mounting
Internal
mounting
External
mounting
280
550
T1
T3
T2
T5
T4
Useful cooling capacity 500 W (1708 BTU)
Useful cooling capacity 750 W (2561 BTU)
Partial
internal
mounting
External
mounting
Internal
mounting
262
266
280
480 15.5
550
Ø 8 (4x)
532
254
280
200
18 x 45°
Ø 8 (4x)
(230)
524
266
492 25
518
550
Ø 19 (2x)
254
266
18 x 45°
Ø 8 (4x)
(230)
280
524
492 25
518
550
Mounting cutout
external mounting
Mounting cutout
partial internal
mounting
Mounting cutout
internal mounting
D (T1) D (T2) D (T3) D (T4) D (T5)
500 W
(1708 BTU)
200
(7.9)
100
(3.9)
100
(3.9)
158
(6.2)
42
(1.7)
750 W
(2561 BTU)
280
(11.0)
125
(4.9)
155
(6.1)
235
(9.3)
45
(1.8)
Wall-mounted air conditioners
Climate Control
123Climate Control
C
4.
Climate Control
950
400
4.1 Wall-mounted air conditioners
Useful cooling capacity 1500/2000 W (5123/6830 BTU)
Mounting cutout
external mounting
Mounting cutout
internal mounting
Mounting cutout
partial internal
mounting
External
mounting
Internal
mounting
Partial
internal
mounting
260
155
105
50
210 370
330
Ø 9.5 (4x)
380
950
920
920
25 x 45°
400
380
Ø 9.5 (4x)
400
370
R6 (4x) 25
920
920
950
2
25 x 45°
400
345
280
235
255
950
15
350
25
Ø
385
1580
400
Useful cooling capacity 1500/2000 W (5123/6830 BTU)
Mounting cutout
partial internal mounting,
internal mounting
Mounting cutout
external mounting
50
240
145
145
290
400
370
320
320
Ø 13 (4x)
1558
1554
1540
1580
Ø 9.5 (2x)
25
Ø 9.5 (2x)
376
280
350
Ø 13 (10x)
400
35
295
380
1580
260
25 550
320
275
340
325
External
mounting
Internal
mounting1)
Partial
internal
mounting
1) For installation in 600 mm (23.6˝) wide doors, move the mounting cutout
from the center of the door to the hinged side by at least 10 mm (0.4˝).
500
1580
Useful cooling capacity 4000 W (13,661 BTU)
Mounting cutout
partial internal mounting
Mounting cutout
external mounting
340 145 195
External
mounting
Partial internal
mounting
500
362
1530
1550
25
474
Ø 13 (4x)
1580
500
380
440
440
Ø 13 (10x)
45330
1580
164
360
380500
375 380
275
25
Climate Control
Wall-mounted air conditioners
124 Climate Control
C
4.
Climate Control
450
1580
382
2
0
5
40
40 1500
Ø 8
(10x) 155
354
345
326
354
240 55
260
165.5
353 360
85.5 360 353 78.5
354
354
49
1510
400
4.1 Wall-mounted air conditioners
Useful cooling capacity 1500 W (5123 BTU)
(SK 3366.XXX and SK 3377.XXX)
Mounting cutout
external mounting
Mounting cutout
internal mounting
Internal
mounting
External
mounting
285
620
238
298
185
285
262
12
190
172
17076
19
173.5
259
220
70
143.5
620
Ø 8 (8x)
Design NEMA 4X, useful cooling capacity 500 W (1708 BTU)
External
mounting
Mounting cutout
external mounting
405
1020
358
245
298
38.5
235
1020
350
93
350
Ø 9.5 (8x)
83 385 255
345
280
405
250
Design NEMA 4X, useful cooling capacity 1000/1500 W (3415/5123 BTU)
External
mounting
Mounting cutout
external mounting
Wall-mounted air conditioners
Climate Control
125Climate Control
C
4.
Climate Control
405
1650
388
275
328
37
295
1650
260
408
320
Ø 13 (10x)
550 380
405
280
350
93 275 325
4.1 Wall-mounted air conditioners
Design NEMA 4X, useful cooling capacity 2000/2500 W (6830/8538 BTU)
External mounting Mounting cutout
external mounting
Climate Control
Chillers
126 Climate Control
C
4.
Climate Control
4.2 Options for chillers
Pressure-sealed system
Open system with tank
Designed as a once-through cooler without tank
Hot gas bypass control in the cooling circuit
More powerful pump(s)
Heater in the tank (1000 W)
Water level switch
Flow monitor
Water filter/oil filter
Water-cooled condenser
Upstream pipework, free from non-ferrous metals
Automatic tank filling
Fault signal with individual messages
Ambient temperature control
Automatic bypass
Manual bypass
Harting connector
Outdoor siting
Special spray finish
Special voltage
Metal filter mat
Castors
Refrigerant R134a
Double pump unit
Filter mat monitoring
Base tray
Tank (stainless steel 1.4301)
Additional medium connections
Chillers mini and mini for wall-mounting
SK 3318.600 – – ▫ –– – ▫ ▫ ––▫ – ▫ ▫ ▫ ▫ ▫ ▫ ▫ – –––
SK 3318.610 – ––▫ –– – ▫ ▫ ––▫ – ▫ ▫ ▫ ▫ ▫ ▫ ▫ – –––
SK 3319.600 – – ▫ –– – ▫ ▫ ––▫ – ▫ ▫ ▫ ▫ ▫ ▫ ▫ – –––
SK 3319.610 – ––▫ –– – ▫ ▫ ––▫ – ▫ ▫ ▫ ▫ ▫ ▫ ▫ – –––
SK 3320.600 – – ▫ ▫ ▫ ▫ – ▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ – – –
SK 3334.600 – – ▫ ▫ ▫ ▫ – ▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ – – –
SK 3360.100 – – ▫ ▫ – ▫ – ▫ ▫ ––▫ – ▫ ▫ – ▫ ▫ ▫ – – –––
SK 3360.250 – – ▫ ▫ – ▫ – ▫ ▫ ––▫ – ▫ ▫ – ▫ ▫ ▫ – – –––
SK 3360.400 – – ▫ ▫ – ▫ – ▫ ▫ ––▫ – ▫ ▫ – ▫ ▫ ▫ – – –––
Chillers freestanding and industrial enclosure
SK 3336.100 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ––– ▫
SK 3336.200 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ––– ▫
SK 3336.300 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ––– ▫
SK 3336.500 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ––– ▫
SK 3336.600 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ––– ▫
SK 3336.650 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ––– ▫
SK 3336.700 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3336.710 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3336.720 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3336.730 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3336.740 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3336.750 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3339.100 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3339.200 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––– ▫
SK 3339.300 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––––▫
SK 3339.400 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––––▫
SK 3339.500 – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –––––▫
Chillers freestanding enclosure for oil
SK 3337.200 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.300 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.500 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.600 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.650 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.700 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.710 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.720 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.730 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.740 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
SK 3337.750 ▫ ▫ ▫ ▫ – ▫ ▫ –––▫ ▫ ––▫ ▫ ▫ ▫ ▫ ▫ ––––▫ ▫
Chillers in the TS8 modular system
SK 3335.060 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
SK 3335.075 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
SK 3335.100 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
SK 3335.120 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
SK 3335.150 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
SK 3335.200 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
SK 3335.250 – – ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ –
Standard
▫ Optional
Chillers
Climate Control
127Climate Control
C
4.
Climate Control
4.2 Options for chillers
Water-cooled condenser
Radial fan
Hot gas bypass control in the cooling circuit
Harting connector
Special spray finish
Special voltage
Ambient temperature control
Control voltage 24 V DC
Liquid injection valve
Fault signal “Filter mat dirty”
Immersion depth 650 mm (25.6˝)
Immersion depth 750 mm (29.5˝)
Immersion depth 850 mm (33.5˝)
Immersion depth 1000 mm (39.4˝)
Immersible chillers
SK 3338.020 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.040 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.060 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.080 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.100 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.120 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.140 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.160 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.180 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.200 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.220 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.240 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.260 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.280 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.300 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.320 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.340 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.360 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.500 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.520 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.540 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.560 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.580 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.600 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.620 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.640 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.660 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.680 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.700 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.720 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.740 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.760 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.780 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.800 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.820 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
SK 3338.840 ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫ ▫
Standard
▫ Optional
Climate Control
Chillers
128 Climate Control
C
4.
Climate Control
4.2 Chillers
Mini, cooling capacity 960/1490 W (3279/5089 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Expansion valve
Filter dryer
Filling
Vent valve
Temperature sensor
Pump
Flow monitor
Overpressure valve
Pressure relief valve
High-pressure switch
5
25
20
35
50
55
61
45
15
10
70
1
60
65
P
T
S
Layout diagram
1
5
10
15
20
25
35
45
50
55
60
61
65
70 60 Hz
6481012
H
Q
0
10
20
30
40
.
50 Hz
2.50 5.0 7.5 10
0
10
20
30
40
H
Q
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Characteristic curves of pump
Part No. SK
3318.600/3318.610/
3319.600/3319.610
Note:
With a lockable external cooling cycle, a bypass
(overpressure valve) should be provided in the
external water pipes.
Mini, cooling capacity 3000/4500 W (10,246/13,661 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Expansion valve
Filter dryer
Tank
Filling
Tank drain
Water level switch, optional
Temperature sensor
Pump
Flow monitor
High-pressure switch
55
40
30
60
1
70
10
15
5
35
46
50
20
25
P
S
Layout diagram
1
5
10
15
20
25
30
35
40
46
50
55
60
70
Note:
With a lockable external cooling cycle, a bypass
(overpressure valve) should be provided in the
external water pipes.
60 Hz
0
15
30
45
60
H
Q
200406080
.
50 Hz
0
15
30
45
60
H
Q
200406080
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Characteristic curves of pump
Part No. SK
3320.600/3334.600
Chillers
Climate Control
129Climate Control
C
4.
Climate Control
4.2 Chillers
Mini, for wall-mounting, cooling capacity 1000/2500/4000 W
(3415/8538/13,661 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Expansion valve
Filter dryer
Tank
Filling
Tank drain
Water level switch, optional
Temperature sensor
Pump
Flow monitor
High-pressure switch
5
15
10
1
70
60
55
35
40
30
50
46
25
20
P
S
Layout diagram
1
5
10
15
20
25
30
35
40
46
50
55
60
70
Characteristic curves of pump
Part No. SK
3360.100/3360.250/
3360.400
50 Hz
H
Q
0
10
20
30
100203040
.
60 Hz
H
Q
0
10
20
30
40
100203040
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Note:
With a lockable external cooling cycle, a bypass
(overpressure valve) should be provided in the
external water pipes.
Freestanding enclosure, cooling capacity 2100 to 7700 W
(7172 to 26,267 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Multi-coil vaporizer
Capillary tube/expansion valve1)
Filter dryer
Tank
Pressure gauge
Filling
Tank drain
Level indicator
Pump
High-pressure switch
Thermostat
1) from SK 3336.500
5
10
25
35
40
48
19
55
30
16 31
1
80
70
P
Layout diagram
1
5
10
16
19
25
30
31
35
40
48
55
70
80
Characteristic curves of pump
Part No. SK
3336.100/3336.200/3336.300/
3336.500/3336.600/3336.650
50 Hz
H
Q
20
0
25
30
35
3020 40 50 60
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Note:
With a lockable external cooling cycle, a bypass
(overpressure valve) should be provided in the
external water pipes.
Climate Control
Chillers
130 Climate Control
C
4.
Climate Control
Characteristic curves of pump
Part No. SK
3336.700/3336.710/3336.720
4.2 Chillers
Freestanding enclosure, cooling capacity 10000 to 25200 W (34,152 to 86,063 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Expansion valve
Inspection glass
Magnetic valve
Liquid collector
Filter dryer
Tank
Pressure gauge
Filling
Tank drain
Level indicator
Pump
Flow monitor
High-pressure switch
Low-pressure switch
Shut-off valve
Thermostat
20
22
21
25
23
55
30 31
35
48
40
60
15
80
71
70
5
73
73
1
10
Layout diagram
1
5
10
15
20
21
22
23
25
30
31
35
40
48
55
60
70
71
73
80
60 Hz
3520 50 65 80
H
Q
25
30
35
40
45
.
50 Hz
3520 50 65 80
H
Q
20
25
30
35
40
.
Part No. SK
3336.730/3336.740/3336.750
60 Hz
4020 60 80 100
H
Q
30
40
50
60
.
50 Hz
4020 60 80 100
H
Q
30
40
50
60
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Note:
With a lockable external cooling cycle, a bypass
(overpressure valve) should be provided in the
external water pipes.
Freestanding enclosure for oil, cooling capacity 2550 to 7900 W (8709 to 26,980 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Capillary tube/expansion valve1)
Filter dryer
Pressure gauge
Automatic bypass valve
Oil pump
Motor for oil pump
High-pressure switch
Thermostat
Anti-frost thermostat
1) from SK 3337.500
5
1
80
31 56
32
57
81
19
25
15
10
70
P
Layout diagram
1
5
10
15
19
25
31
32
56
57
70
80
81
Chillers
Climate Control
131Climate Control
C
4.
Climate Control
4.2 Chillers
Freestanding enclosure for oil, cooling capacity 10600 to 26100 W (36,201 to 89,136 BTU)
Key to the
adjacent drawing:
Compressor Pressure gauge
Condenser Automatic bypass valve
Condenser fan Oil pump
Evaporator coil Motor for oil pump
Expansion valve High-pressure switch
Inspection glass Low-pressure switch
Magnetic valve Shut-off valve
Liquid collector Thermostat
Filter dryer Anti-frost thermostat
31
73
15
20
22
21
25
23
81
73
1
70
80
71
56
57 32
5
10
M
Layout diagram
1 31
5 32
10 56
15 57
20 70
21 71
22 73
23 80
25 81
In TS8 modular enclosure system, cooling capacity 6000/7500 W (20,491/25,614 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Multi-coil vaporizer
Expansion valve
Inspection glass
Liquid collector
Filter dryer
Tank
Pressure gauge
Fixed pump bypass
Filling
Tank drain
Level switch
Pump
High-pressure switch
Thermostat
33
35
16
47
70
20
1
80
31
55
40
30
21
23
25
10
5
Layout diagram
1
5
10
16
20
21
23
25
30
31
33
35
40
47
55
70
80
Characteristic curves of pump
Part No. SK
3335.060/3335.075
50 Hz
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
3020 40 50 60
H
Q
12
16
20
24
28
.
.
In TS8 modular enclosure system, cooling capacity 10000 to 25000 W (34,152 to 85,379 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Multi-coil vaporizer
Expansion valve
Inspection glass
Liquid collector
Filter dryer
Tank
Pressure gauge
Fixed pump bypass
Filling
Tank drain
Level switch
Pump
High-pressure switch
Thermostat
33
35
16
47
70
20
1
80
31
55
40
30
21
23
25
10
5
Layout diagram
1
5
10
16
20
21
23
25
30
31
33
35
40
47
55
70
80
Characteristic curves of pump
Part No. SK
50 Hz 3335.200/3335.250
6030 90 120 150
H
Q
20
26
32
38
44
50
.
50 Hz 3335.100/3335.120/
3335.150
3020 40 50 60
H
Q
20
26
32
38
44
50
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Climate Control
Chillers/Immersible chillers
132 Climate Control
C
4.
Climate Control
4.2 Chillers
In industrial enclosure, cooling capacity 32 kW to 172 kW (109,286 to 587,411 BTU)
1) Layout diagram SK 3339.300 – .500
available on request.
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Expansion valve
Inspection glass
Magnetic valve
Liquid collector
Filter dryer
Tank
Pressure gauge
Filling
Tank drain
Level indicator
Pump
Flow monitor
High-pressure switch
Low-pressure switch
Shut-off valve
Thermostat
31
30
60
15
71
80
70
73
10
5
23
25
21
22 20
73
1
48
35
40
55
Layout diagram SK 3339.100/.2001)
1
5
10
15
20
21
22
23
25
30
31
35
40
48
55
60
70
71
73
80
50 Hz 3339.100/3339.200 60 Hz 3339.100/3339.200
907050 110 150130 170
H
Q
35.0
37.5
40.0
42.5
45.0
.
8050 110 140 170
H
Q
15
20
25
30
.
50 Hz 3339.300/3339.400
1000 200 300 400
H
Q
18
23
28
33
38
.
50 Hz 3339.500
0 200 400 600 800
H
Q
20
25
30
35
40
.
H = Delivery head H [m]
Q = Delivery flow Q [l/min]
.
Characteristic curves of pump
Part No. SK
50 Hz 3339.450
0 100 200 300 400
15
20
25
30
H
Q
.
35
40
50
45
50 Hz 3339.250, 3339.280
80 120 160 200 250
25
30
35
40
H
Q
.
4.2 Immersible chillers
Useful cooling capacity 2400 to 77900 W (8196 to 266,042 BTU)
Key to the
adjacent drawing:
Compressor
Condenser
Condenser fan
Evaporator coil
Expansion valve
Inspection glass
Magnetic valve
Liquid collector
Filter dryer
Tank, to be supplied by the
customer
Temperature sensor
High-pressure switch
Low-pressure switch
Thermostat
Stirrer
5
80
70
1
71
30
50
82
20
22
23
21
25
10
15
Layout diagram
1
5
10
15
20
21
22
23
25
30
50
70
71
80
82
Air/water heat exchangers
Climate Control
133Climate Control
C
4.
Climate Control
4.3 Air/water heat exchanger
Micro, wall-mounted, useful cooling capacity 300 W (1025 BTU)
Mounting cutout
for external mounting
Cooling water connection
Condensate discharge
1
2
Mounting holes
for internal mounting
85
18
55
12
300
150
60
300
276
232
41
150
125
102
Ø 7 (4x)
300
276
102
150
Ø 7 (4x)
Wall-mounting, useful cooling capacity 600 W (2049 BTU)
Mounting holes
for internal mounting
420
200
500
150
Ø 7
80
500
200
420
500
170 50
3030
133
150
150
160
200
130
145
160
34
Ø 7
4x
18
75
100
1
2
Mounting cutout
for external mounting
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
Wall-mounting, useful cooling capacity 1000 W (3415 BTU)
Mounting holes
for internal mounting
298
240
475
520
Ø 7
298
520
50
520
298
272
240
475
230
120
127 33
208
Ø 7
135
93 2
1
Mounting cutout
for external mounting
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
Climate Control
Air/water heat exchangers
134 Climate Control
C
4.
Climate Control
Ø 7 (4x)
11
920
200
140
100
18
75
2
1
80
950
200
175
170 15
475
250 24
126
96
19 920
950
164
140
Ø 7 (6x)
4.3 Air/water heat exchanger
Wall-mounting, useful cooling capacity 1250 W (4269 BTU)
Mounting holes
for internal mounting
Mounting cutout
for external mounting
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
825
765
350
380
Ø 8
105
45
85
825
380
1
2
300
133
85
470
200
320
35
75
750
825
25
40
380
Ø 8
Wall-mounting, useful cooling capacity 1540 W (5259 BTU)
Mounting holes
for internal mounting
Mounting cutout
for external mounting
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
400
950
Ø 7
340
340
400
280
112 463 60
280
904
950
Wall-mounting, useful cooling capacity 2250/3000 W (7684/10,246 BTU)
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
200
2
1
Mounting cutout
for external/internal mounting
Only the 4 mounting holes,
7 mm (0.3˝) diameter, are
required for internal mounting.
Air/water heat exchangers
Climate Control
135Climate Control
C
4.
Climate Control
250
100
450
350
410
15
33.5
440
711.5
180
455 455
1400
455
433.5
Ø 8
420
451
Ø 8 (10x)
350
433.5
350
417
417
442.5
230
145
442.5 442.5
442.5
530
30
15
4.3 Air/water heat exchangers
Wall-mounting, useful cooling capacity 4500 W (15,368 BTU) and 7000 W (23,906 BTU)
Mounting cutout
for external mounting
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
450
1400
80
2
1
(300*)
(180*)
( )* Dimensions
for SK 3216.480
Roof-mounted, useful cooling capacity 2500 W (8538 BTU)
Roof-mounted, useful cooling capacity 4000 W (13,661 BTU)
490
597
390
420
475
597
380
27
Ø 100 (4x)
475
280
420
415
1 2
Condensate discharge 1/2˝
Cooling water connection 1/2˝
1
2
1
3
2
1190
40
20
94
1
3
2
1190
40
20
94
As a sidewall for 600 mm (23.6˝) deep TS8 modular enclosures, useful cooling capacity 700 W (2391 BTU)
Water connections
Hose 10 mm (0.4˝) diameter
Condensate discharge
1
2
3
390
562
57
496
150
1346
1546
1797
495
400
45
390
562
57
496
150
1346
1546
1997
495
400
45
SK 3316.180 SK 3316.200
Climate Control
TopTherm air/air heat exchangers
136 Climate Control
C
4.
Climate Control
280
550
501
251
18 x 45°
280
(230)
200
254
524
Ø 8 (4x)
Ø 15 (2x)
266
25
492
518
550
280
550
150 42
108
4.3 TopTherm air/air heat exchanger
Wall-mounted, specific thermal capacity 17.5 W/C
Mounting cutout
for external mounting
Mounting cutout
for internal mounting
Internal
mounting
External
mounting
400
250
345
280
36.5
235
255
950
15
350
25
Ø 9.5 (8x)
385
350
380
Ø 9.5 (4x)
400
370
R6 (4x) 25
920
920
950
2
25 x 45°
950
400 205 (225)
50
155 (175)
Wall-mounting, specific thermal capacity 30 – 60 W/C
Mounting cutout
for external mounting
Mounting cutout
for internal mounting
External
mounting
Internal
mounting
Dimensions in brackets for 45 W/C and 60 W/C
280
350
Ø 13 (8x)
400
35
295
380
1580
260
25 875
320
275
340
400
370
324
324
Ø 13 (4x)
1558
1554
1535
1580
Ø 12 (2x)
25
R6 (2x)
376
1580
400 215 50
165
Wall-mounted, specific thermal capacity 90 W/C
Mounting cutout
for external mounting
Mounting cutout
for internal mounting
External
mounting
Internal mounting
Air/air heat exchangers/rack-mounted climate control
Climate Control
137Climate Control
C
4.
Climate Control
200
32.5
130135.5
1
147
36
159
400
1
164
364
400
1360
110
280
35
25
295
380
110325
275 (655)
1360
25
30.5
75
350
210
340
280
400
Ø 13 (8x)
Ø 30
Air/air heat exchanger
Wall-mounted
Back side
SK 3129.800
Mounting cutout
for external and
internal mounting
Mounting cutout
for external mounting
External
mounting
Side view
Optional cable pass-through
1
542
38
445
3
4.5 Rack-mounted air conditioner
For 482.6 mm (19˝), useful cooling capacity 1000 W (3415 BTU)
482.6 (19″)
190.5
6 HE = 265.9
6.8 x 10.3 220
80
32
View of the rear of the unit
Air duct, extendible to any length
Service flap (thermostat)
1
1
HE = U
4.5 Rack-mounted fan
For 482.6 mm (19˝), air displacement 320/480 m3/h (188/283 cfm)
Rack-mounted fan mounted between
a pair of 482.6 mm (19˝) rails
Vario rack-mounted fan
mounted in subracks 84 HP
Vario rack-mounted fan mounted between
a pair of 482.6 mm (19˝) rails
1
2
4.5 Centrifugal fan
Air displacement 320 m3/h (188 cfm)
465.1
482.6 (19″)
76.2
88
380
17
163
75 60
Front grille
Climate Control
Climate control tailored to enclosures/heaters
138 Climate Control
C
4.
Climate Control
250
345
265
360
280
Ø 8
4.5 Roof-mounted fan
Air displacement 360 m3/h (212 cfm)
Without fan With fan
Mounting cutout
□ 260 x 340
15
50
44
420
340
550
500
99
125
20
370
290
475 + 1
260 + 1
4.5 Roof-mounted fan and vent attachment
Air displacement (unimpeded air flow) 400/800 m3/h (235/471 cfm)
Mounting cutout
T1
D
36.5
133
223.5
3
C
B1
B2
4.5 Fan roof, modular, two-piece for TS/FR(i)
Air displacement per fan (unimpeded air flow) 160/180 mm3/h (94/106 cfm) at 50/60 Hz
For enclosures Cover plate Roof dimensions
CD
Part No.
TS
W (B)
mm
(inches)
D (T)
mm
(inches)
Solid Vented
W
(B1)
W
(B2)
D
(T1)
mm (inches)
600
(23.6)
600 (23.6) 2102.180 2102.400
567.5
(22.3)
435
(17.1)
567.5 (22.3)
400
(15.7)
224 (8.8) 7826.366
800 (31.5) 2102.190 2102.410 767.5 (30.2)
424
(16.7)
7826.368
900 (35.4) 2102.190 2102.410 867.5 (34.2) 7826.369
1000 (39.4) 2102.190 2102.410 967.5 (38.1) 7826.360
800
(31.5)
600 (23.6) 7885.100 7885.200
767.5
(30.2)
635
(25.0)
567.5 (22.3)
600
(23.2)
224 (8.8) 7826.486
800 (31.5) 7886.100 7886.200 767.5 (30.2)
424
(16.7)
7826.488
900 (35.4) 7886.100 7886.200 867.5 (34.2) 7826.489
1000 (39.4) 7886.100 7886.200 967.5 (38.1) 7826.480
110
45
64
185
64
45
4.6 Enclosure heaters
Continuous thermal output 10 – 300 W (40 – 1030 BTU)
75
45
35
80
125
45
35
130
80
118
140
25
5.2
8.25
162
100
168
□ 120
SK 3105.000 SK 3106.000 SK 3107.000 SK 3115.000 SK 3116.000SK 3102.000
including fan
Accessories for climate control
Climate Control
139Climate Control
C
4.
Climate Control
79.5
79.5
6
71.5
71.5
4.3
310
38
33
1
4.6 Axial fan
For heater SK 3107.000
Grounding lug for
M4 or 8 – 32 UNC
1
258
125
132.5
42
Ø 6
280
378
400
125
42
132.5
Ø 6
Ø 6
258
75
50
25
1
3
2
378
45
6025
Ø 6
1
3
2
4.7 Electronic condensate evaporator
SK 3301.560/.580 SK 3301.570/.590
Condensate hose
SK 3301.608 for SK 3302.XXX
SK 3301.610 for SK 3303.XXX
Suggestion for position of cable entry
Hose
Length as required
1
2
3
Condensate hose SK 3301.612
Suggestion for position of cable entry
Hose
Length as required
1
2
3
4.7 Integrated louvers
B
A
140
100
160
50
110
90
4.5
10
1.5
8
10
150
210
190
80
40
100
B
A
1.5
8
4.5
10
4.5
270
330
310
50
110
90
B
A
1.5
8
SK 2541.235 SK 2542.235 SK 2543.235
R
Switch to perfection
Comprehensive – Solutions By Rittal
Rittal offers one of the largest off-the-shelf delivery programs
for industrial enclosures. Rittal’s integrated solution concept
includes mechanical development and installation, power
supplies, electrical components, climate control and
centralized surveillance (CMC) solutions, fully equipped and
functioning at delivery.
Rittal is well prepared to meet all of your packaging needs.
Rittal is always close by, wherever you may be developing
your customer’s solutions. Global production, distribution
and service guarantees close proximity to the customer at
all times, worldwide.
08/05
A350
Air Conditioners Chiller Systems Heat-Exchangers
Filter Fans 19″-Rackmount Climate Control Heaters
IT Cooling
19
˝
Electronic
Components
IT Solutions
Communication Systems
Enclosure
Climate Control
& Process Cooling
Busbar
Power Distribution
Industrial
Enclosure Systems
Rittal Corporation
801 State Route 55
Urbana, OH 43078
Phone: (937) 399-0500
Fax (937) 390-5599
Toll-free: 1-800-477-4000
Internet: www.rittal-corp.com
eMail: rittal@rittal-corp.com