JHBL Installtion Instructions U219813 Installation Directions
2016-10-06
: Pdf 169969-Installationsheet 169969-InstallationSheet B5 unilog
Open the PDF directly: View PDF .
Page Count: 5
LEDIMPORTANTSAFETYINSTRUCTIONS
Toreducetheriskofdeath,personalinjuryorpropertydamagefromfire,electricshock,fallingparts,cuts/abrasions,and
otherhazardspleasereadallwarningsandinstructionsincludedwithandonthefixtureboxandallfixturelabels.
Beforeinstalling,servicing,orperformingroutinemaintenanceuponthisequipment,followthesegeneralprecautions.
Installationandserviceofluminairesshouldbeperformedbyaqualifiedlicensedelectrician.
Maintenanceoftheluminairesshouldbeperformedbyperson(s)familiarwiththeluminaires’constructionandoperation
andanyhazardsinvolved.Regularfixturemaintenanceprogramsarerecommended.
Itwilloccasionallybenecessarytocleantheoutsideoftherefractor/lens.Frequencyofcleaningwilldependonambient
dirtlevelandminimumlightoutputwhichisacceptabletouser.Refractor/lensshouldbewashedinasolutionofwarm
waterandanymild,non‐abrasivehouseholddetergent,rinsedwithcleanwaterandwipeddry.Shouldopticalassembly
becomedirtyontheinside,wiperefractor/lensandcleaninabovemanner,replacingdamagedgasketsasnecessary.
DONOTINSTALLDAMAGEDPRODUCT!Thisluminairehasbeenproperlypackedsothatnopartsshouldhavebeen
damagedduringtransit.Inspecttoconfirm.Anypartdamagedorbrokenduringorafterassemblyshouldbereplaced.
Recycle:ForinformationonhowtorecycleLEDelectronicproducts,pleasevisitwww.epa.gov.
Theseinstructionsdonotpurporttocoveralldetailsorvariationsinequipmentnortoprovideeverypossiblecontingency
tomeetinconnectionwithinstallation,operation,ormaintenance.Shouldfurtherinformationbedesiredorshould
particularproblemsarisewhicharenotcoveredsufficientlyforthepurchaser’sorowner’spurposes,thismattershouldbe
referredtoAcuityBrandsLighting,Inc.
READANDFOLLOWALLSAFETYINSTRUCTIONS!
SAVETHESEINSTRUCTIONSANDDELIVERTOOWNERAFTERINSTALLATION
Disconnectorturnoffpowerbefore
installationorservicing.
Verifythatsupplyvoltageiscorrectby
comparingitwiththeluminairelabel
information.
Makeallelectricalandgrounded
connectionsinaccordancewiththeNational
ElectricalCode(NEC)andanyapplicable
localcoderequirements.
Allwiringconnectionsshouldbecapped
withULapprovedrecognizedwire
connectors.
WARNING
RISKOFELECTRICSHOCK
Allowlamp/fixturetocoolbeforehandling.
Donottouchenclosureorlightsource.
Donotexceedmaximumwattagemarkedon
luminairelabel.
Followallmanufacturer’swarnings,
recommendationsandrestrictionsfor:driver
type,burningposition,mounting
locations/methods,replacementand
recycling.
WARNING
RISKOFBURN
Wearglovesandsafetyglassesatalltimes
whenremovingluminairefromcarton,
installing,servicingorperforming
maintenance.
Avoiddirecteyeexposuretothelightsource
whileitison.
CAUTION
RISKOFINJURY
Keepcombustibleandothermaterialsthat
canburn,awayfromlamp/lens.
Donotoperateincloseproximitytopersons,
combustiblematerialsorsubstances
affectedbyheatordrying.
CAUTION
RISK OF FIRE
LEDIMPORTANTSAFETYINSTRUCTIONS
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory
statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and
Conditions, please visit www.acuitybrands.com.
OurBrands Indoor/Outdoor IndoorLighting OutdoorLighting Controls Daylighting
LithoniaLighting Gotham AmericanElectricLighting DARKTOLIGHT SunOptics
Carandini MarkArchitecturalLighting AntiqueStreetLamps LC&D
HolophanePeerlessHydrelROAM
RELOC RenaissanceLighting Tersen SensorSwitch
LightConceptsWinonaLightingSynergy
AcuityBrandsLighting,Inc.assumesnoresponsibilityforclaimsarisingoutofimproperorcarelessinstallationorhandlingofitsproducts.
ABLLEDGeneralWarnings,FormNo.503.203
©2010AcuityBrandsLighting,Inc.Allrightsreserved.12/01/10
Neverconnectcomponentsunderload.
Donotmountorsupportthesefixturesinamannerthatcancuttheouterjacketordamagewire
insulation.
Unlessindividualproductspecificationsdeemotherwise:NeverconnectanLEDproductdirectlytoa
dimmerpacks,occupancysensors,timingdevices,orotherrelatedcontroldevices.LEDfixturesmustbe
powereddirectlyoffaswitchedcircuit.
Unlessindividualproductspecificationsdeemotherwise:Donotrestrictfixtureventilation.Allowfor
somevolumeofairspacearoundfixture.AvoidcoveringLEDfixtureswithinsulation,foam,orother
materialthatwillpreventconvectionorconductioncooling.
Unlessindividualproductspecificationsdeemotherwise:Donotexceedfixturesmaximumambient
temperature.
Onlyusefixtureinitsintendedlocation.
LEDproductsarePolaritySensitive.EnsureproperPolaritybeforeinstallation.
ElectrostaticDischarge(ESD):ESDcandamageLEDfixtures.Personalgroundingequipmentmustbe
wornduringallinstallationorservicingoftheunit.
DonottouchindividualelectricalcomponentsasthiscancauseESD,shortenlamplife,oralter
performance.
Somecomponentsinsidethefixturemaynotbeserviceable.Intheunlikelyeventyourunitmayrequire
service,stopusingtheunitimmediatelyandcontactanABLrepresentativeforassistance.
Alwaysreadthefixturescompleteinstallationinstructionspriortoinstallationforanyadditionalfixture
specificwarnings.
CAUTION:RISKOFPRODUCTDAMAGE
LEDIMPORTANTSAFETYINSTRUCTIONS
SECTION1:INSTALLATIONOFNEWLUMINAIRE
Caution:Protectlensandoccupancysensorwhensettingluminairedown.
1) Ifreplacingexistingfixtures,disconnectallpowertotheexistingluminaireandremovetheexistingluminairefromthe
ceiling.
2) RemovethenewLEDhighbayfrompackagingandinspectforanydamages.HandlenewLEDfixturewithcare.Donotset
thefixturedownonthelens.Ifdamageddonotuse;callyourlocalrepforreplacement.
3) Thisfixtureisdesignedtohangfromthesuppliedhookora¾‐14NPSorNPTschedule80pipe(notprovided).Ifusingpipe,
useathreadsealant(notprovided)tosealthethreadstopreventwaterfromenteringthefixture.Provideandinstalla
suitablemountingstructureinaccordancewithlocalcodesthatiscapableofsupportingthefullweight(43lbs)ofthe
luminaire.Ifinstallingluminaireontopipe,threadpipeaminimumof5fullturnsontoluminaireandtorquepipeto35ft.
lbs.Tightensetscrewonspliceboxto35in.lbs.Thisluminaireisnotsuitableforuseinhighvibrationareas.Theluminaire
shallnotbelocatedinareaswheretheluminaireexperiencesvibrationinexcessof1/2Gatitscenterofgravitypoint.To
determineifvibrationispresentatorneareachluminairelocation,useaportableaccelerationmonitoringdevice.
4) ConnecttheLEDhighbaywiringtolinewire,black‐to‐black,white‐to‐whiteandgreen‐to‐green.Purpleandgraywiresare
for0‐10Vdimmingandshallbecappedwithawirenut(notprovided)foreachwirewhennotused.UseonlyULlisted
wiringconnectors90C(orgreater)andULlistedwiring(90Corgreater).Wirescanbepulledthroughanyofthebelow
accessplatesperlocalcode.Leadwiresarenormallylocatedbehindthe“AccessPlateForSpliceBox”openingjustunder
thehook.
5) XpointwirelesscontrolsrequireasecondaryfieldcommissioningtoconnecttotheXpointnetwork.
6) Wipeoffexteriordirtanddebrisusingasoftcleancloth.Donotuseabrasivecleanersonopticalsurfacesasthismayresult
inlossofopticalefficiency.
Figure1
LEDIMPORTANTSAFETYINSTRUCTIONS
SECTION2:OptionalEquipment
ThisLEDhighbayfixturecanbeorderedwithmultipleoptionswhichmayormaynotbepresentonthefixtureyouareinstalling.
Commonsoptionsare:
1. WireGuard–protectsthelensfromdamage.
2. OccupancySensor–turnsfixtureonoroffbasedonmotiondetectedwithinthespace.
3. EmergencyTestSwitchandIndicatorLight–usedtotestthefunctionoftheemergencybatterypackwhichislocatedinside
thedriverhousing.Pushingtheswitchwillturnofftheincomingpowertothefixtureandswitchitovertobatterypower.
ItisnormalforonlyonesectionofLEDstolightupduringemergencybatterymode.
4. EmergencyLightingMaximumMountingHeight‐Fixturesequippedwithemergencybatterybackupsystemsmaybe
mountednohigherthan30ftperUL924.
5. Forluminaireswithacrylicorpolycarbonateopticallenses,pleasereferencethefollowinglinkforchemicalcompatibility
information:http://www.acuitybrandslighting.com/library/ll/documents/otherdocuments/acrylic‐polycarbonate‐
compatibility.pdf
Figure2
LEDIMPORTANTSAFETYINSTRUCTIONS
SECTION3:SERVICING
1) DisconnectallpowertotheLEDhighbaybeingservice.
2) Removethefixturefromceiling.Servicecannotbeperformedwhilefixtureisinstalled.
3) Allserviceshouldbeperformedbyaqualifiedlicensedelectrician.UseonlyULlistedcomponents.
4) Donotsetthefixtureonthelensorsensor.
5) Removethefourcornerscrewssothatthetophalfofthedriverhousingcanberemoved.Becarefulnottopinch,damage,
orpullanywiring.
6) TheLEDdriversmaybechangedbyremovingthemountingbracketshownbelow.
7) Fusesandsurgeprotectorscanbeservicedwithoutremovingthemountingbracket.
Figure3
Ifthereareanyquestionsregardingthisinstallationinstruction,pleasecontactourtechnicalsupportdepartment.Five‐yearlimited
warranty.Warrantytermsarelocatedat
www.acuitybrands.com/customerresources/term_and_conditions.aspx