Product Detail Manual

2016-08-16

: Pdf 170988-Attachment 170988-Attachment B3 unilog

Open the PDF directly: View PDF PDF.
Page Count: 3

1
Type:
Project:
Qty:
SPECIFICATIONS Interior ARCHER LED
Archer LED
Patient Room Wall Light
Healthcare Lighting • 3 Kilmer Road • Edison, NJ 08817 • 855.868.6980 • f 855.868.6981 • www.healthcare-lighting.com
Rev. 06/08/16
HPW3LED
©2015-2016 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Construction
Extruded aluminum housing
Die-cast aluminum handles
High impact acrylic lenses, UV treated to prevent yellowing with age
Polyester powder coat finish; anti-microbial powder coat finish
available
Wall mount brackets included. Packaged separately.
Source
Nichia LED chips (or equivalent) mounted on linear boards
Driver
Roal Strato RSL035-09 or equivalent
Weight
HPW336 – approximate shipping weight 20 lbs.
HPW348 – approximate shipping weight 30 lbs.
The Archer bed light provides versatility with optional sequential switching for patient room ambient and task lighting. The sleek housing profile echoes the Chrysalite and can be used together to create a
complementary look in a lighting design. Multiple lamping and switching options allow this fixture to be used in a wide array of applications. As a bed light, placement above the patient on the headwall delivers
optimal distribution of light for reading and also comfortable ambient illumination. If a low voltage controller is included (optional), light levels can be adjusted via the nurse call system or using a separate pendant
pillow switch (optional). This fixture is also a good choice for guest lighting.
Delivers multiple light levels for patient: indirect, direct, both
Separate mounting plate makes installation easy; mount rigid but lightweight plate to wall and then install fixture
Low voltage controller (option) allows patient control from nurse call system or separate pillow switch (option)
Tool-free access to ballast compartment while fixture remains on wall
Single-piece extruded aluminum body for extreme durability
Entirely serviceable without removal from wall
SPECIFICATIONS
Voltage
120V
Switching
Line voltage switching (by others)
Low voltage controller (optional) for patient control of up and down
light sequentially from nurse call system or pillow switch (optional)
2-position pull chain for on/off control or 4-position pull chain for
sequential control of up and down light (optional, 120V only)
Input Watts (As Tested)
Top and bottom mode 2U2D configuration, 4ft fixture – 102 WATTS
Top mode 2U2D configuration, 4ft fixture - 51 WATTS
Light Output (As Tested)
Top and bottom mode 2U2D configuration, 4ft fixture - 10860 lumens
Top mode 2U2D configuration, 4ft fixture - 5490 lumens
Dimming
0-10V dimming standard
Color Quality
>80 CRI
Life Estimate
50,000 hours*
*LED life projection based on IES TM-21 and IES LM-80
Listings
CSA certified to meet US and Canadian standards. Damp location listed.
Warranty
5-year limited warranty. Complete warranty terms located at:
www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
Note: Actual performance may differ as a result of end-user
environment and application.
All values are design or typical values, measured under
laboratory conditions at 25 °C.
HPW348 120 LED35 2U2D LV LCR AM
Series Voltage Lamping Type Lamping
HPW336 Archer 3ft in Length
HPW348 Archer 4ft in Length
120 120V LED27 2700K LED
LED30 3000K LED
LED35 3500K LED
LED40 4000K LED
2U1D 2 Rows LEDs Up, 1 Row LEDs Down
2U2D 2 Rows LEDs Up, 2 Rows LEDs Down
1U1D 1 Row LEDs Up, 1 Row LEDs Down
1U2D 1 Row LEDs Up, 2 Rows LEDs Down
0U1DMT Only 1 Row LEDs Down with Top Plate
0U2DMT 2 Rows LEDs Down with Top Plate
1U0DMB Only 1 Row LEDs Up with Bottom Plate
2U0DMB 2 Rows LEDs Up with Bottom plate
CATALOG NUMBER
Example:
Switching Config Option Finish
LV Low Voltage Controller - Sequential Switching
LV1L1LVC with Pillow Switch for Down Light on Left
LV1R1LVC with Pillow Switch for Down Light on Right
LV2L1LVC with Pillow Switch on Left - Sequencing Up + Down Light
LV2R1LVC with Pillow Switch on Right - Sequencing Up + Down Light
S2L2On/Off Pull Chain on Left (top & bottom)
S2R2On/Off Pull Chain on Right (top & bottom)
S2C2On/Off Pull Chain on Center (top & bottom)
S2LDL1,2 On/Off Pull Chain on Left (bottom only)
S2RDL1,2 On/Off Pull Chain on Right (bottom only)
S2CDL1,2 On/Off Pull Chain on Center (bottom only)
S4L1,2 4-Position Pull Chain on Left
S4R1,2 4-Position Pull Chain on Right
S4C1,2 4-Position Pull Chain on Center
SX No Switch
LCL33W LED Chart Light with Switch on Left
LCR33W LED Chart Light with Switch on Right
LCLHW33W LED Chart Light “Hard Wired” Left
LCRHW33W LED Chart Light “Hard Wired” Right
BD Bed-Stop Switch
FW Flat White
(standard)
AM Anti-Microbial
White
CC4Custom Color
Notes are on following page.
Type:
Project:
Qty:
2
Healthcare Lighting • 3 Kilmer Road • Edison, NJ 08817 • 855.868.6980 • f 855.868.6981 • www.healthcare-lighting.com
SPECIFICATIONS Interior ARCHER LED
Archer LED
Patient Room Wall Light
Rev. 06/08/16
HPW3LED
©2015-2016 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
DIMENSIONS
Fixture NOMINAL
LENGTH ACTUAL LENGTH
HPW348 LED 48” 49.56”
HPW336 LED 36” 37.56”
6.85
4.22
BLOCKING BY
OTHERS
SIDE VIEW
CROSS SECTION
Notes
1 Switching: S2 and S4 options are compatible with 120V only
2 For pull chain and pillow switch, specify “left” or “right” as viewed facing the head wall
3 3W LED chart light (option) always installed opposite end from pull chain or pillow switch
4 Custom color requires factory pricing
Installation is made easy by the incorporation of a separate mounting plate (blocking by others).
After the plate is mounted to the wall the fixture can be quickly connected and hung.
It is the responsibility of the party installing the fixture to select appropriate fasteners that are suitable for the wall material and construction.
It is the responsibility of the person inst alling the light fixture to ensure that the materials, hardware and building structural members that are selected will support the light fixture(s) and that they meet
all applicable building and safety codes.
Complete electrical connections according to the wiring diagram on ballast tray, following all applicable building codes and regulations.
MOUNTING INFORMATION
HPW348 LED HPW336 LED
SIDE PROFILE
APPLIES TO ALL PLATES 2458"834"
49316"
46716"
6
1516"7" 7" 6" 7" 7" 6
1516"
LINE VOLTAGE WIRE WAY LOW VOLTAGE WIRE WAY
HOLES FOR 1
4 BOLTS
OR #14 WOOD SCREWS
APPLIES TO ALL PLATES
38"
2916"
FIXTURE MOUNTING STUDS
SEE INSTALLATION INSTRUCTIONS
1858"834"
373
16
"
34716"
6
1316"7" 8
14"7" 6
1316"
LINE VOLTAGE WIRE WAY
LOW VOLTAGE WIRE WAY
"
Type:
Project:
Qty:
3
Healthcare Lighting • 3 Kilmer Road • Edison, NJ 08817 • 855.868.6980 • f 855.868.6981 • www.healthcare-lighting.com
SPECIFICATIONS Interior ARCHER LED
Archer LED
Patient Room Wall Light
Rev. 06/08/16
HPW3LED
©2015-2016 Acuity Brands Lighting, Inc. All Rights Reserved. “Healthcare Lighting” is a registered trademark of Acuity Brands Lighting.
Products herein may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
DIRECT
Test Report: 501927
HPW348-120-LED35-
2U2D-LV1R-LCL-GLR
Lumens: 4,496
Input Wattage: 63.5
Max. Candela: 2,062 H: 15º, V: 7.5º
INDIRECT
Test Report: 501929
HPW348-120-LED35-
2U2D-LV1R-LCL-GLR
Lumens: 4,660.1
Input Wattage: 62.7
Max. Candela: 2,035 H: 10º, V: 157.5º
DIRECT & INDIRECT (All On)
Test Report: 501930
HPW348-120-LED35-
2U2D-LV1R-LCL-GLR
Lumens: 9,077.8
Input Wattage: 125.7
Max. Candela: 2,062 H: 15º, V: 7.5º
PHOTOMETRICS
Photometric data based on test results from an independent NIST traceable testing lab. IES data is available at www.healthcare-lighting.com. Always refer to our website for the latest IES file updates.
Illuminance at a Distance
Height Center Beam
Footcandle
4.0 125.4fc
8.0 31.4fc
12.0 13.9fc
16.0 7.8fc
20.0 5.0fc
Illuminance at a Distance
Height Center Beam
Footcandle
4.0 0fc
8.0 0fc
12.0 0fc
16.0 0fc
20.0 0fc
Illuminance at a Distance
Height Center Beam
Footcandle
4.0 125.4fc
8.0 31.4fc
12.0 13.9fc
16.0 7.8fc
20.0 5.0fc
130º
120º
110º
100º
90º
80º
70º
60º
50º
1,700
1,417
1,133
850
567
283
CD: 0
283
567
850
1,133
1,417
1,700
- 0º H
- 90º H
VA: 0º 10º 20º 30º 40º
180º 170º 160º 150º 140º
130º
120º
110º
100º
90º
80º
70º
60º
50º
130º
120º
110º
100º
90º
80º
70º
60º
50º
- 0º H
- 90º H
VA: 0º 10º 20º 30º 40º
180º 170º 160º 150º 140º 180º 170º 160º 150º 140º
2,700
2,250
1,800
1,350
900
450
CD: 0
450
900
1,350
1,800
2,250
2,700
1,700
1,417
1,133
850
567
283
CD: 0
283
567
850
1,133
1,417
1,700
- 0º H
- 90º H
VA: 0º 10º 20º 30º 40º
Lumen values are from photometric tests from an accredited laboratory. Data is considered to be representative of the configurations
shown, within the tolerances allowed within generally accepted industry tolerances. Actual performance may differ as a result of
end-user environment and application. Contact factory for performance data on any configurations not shown here
Actual performance may differ as a result of end-user environment or application
Lumen Output Electrical Load
For 4ft Fixture
Light Switch Mode Lumen Output Max CD
top and bottom on 10860 lumens 2370 candela
DIRECT: bottom on 5370 lumens 2260 candela
INDIRECT: top on 5490 lumens 2370 candela
For 4ft Fixture
Light Switch Mode Input Watts
top and bottom on 102 watts
DIRECT: bottom on 51 watts
INDIRECT: top on 51 watts
PERFORMANCE DATA