IS 0348 Installation Directions

2014-07-05

: Pdf 262626-Installationsheet 262626-InstallationSheet 804428 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadIS-0348  Installation Directions
Open PDF In BrowserView PDF
INSTRUCTION / INSTALLATION SHEET
• 4 X 12 Telecom Module w/RJ-31x
• 4 X 12 Telecom Module w/RJ-31x &
Configurable Primary Line
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com

IS-0348 Rev. A

1. INTRODUCTION
The On-Q/Legrand 4 X 12 Telecom Module w/RJ-31x (P/N TM1478) and 4 X 12 Telecom Module
with Configurable Primary Line w/RJ-31x (P/N TM1475) are members of our flexible family of
Telephone Distribution Modules, each of which offers different combinations of line pin-outs to
more closely match homeowner needs (see Figure 1).

2. DESCRIPTION

TM1475

The On-Q/Legrand 4 X 12 Telecom Modules distribute four incoming telephone lines to as many
as 12 locations throughout the home (see Figure 2). The module's plug and connect design
makes line reconfiguration simple, and offers the following benefits:
• Includes single bay bracket (P/N 364890-01) for mounting in On-Q style enclosure
• All connectors 8-Pin 8-Conductor (RJ45) wired to T568A
• All ports meet TIA 568A Category 3 specifications
• Verified to comply with FCC Part 68 for unregistered equipment
• 50 microns gold plated contact points

TM1478

Figure 1

• Accepts four incoming telephone lines
• Advanced surge protection with automatically resetting fuse
• Line 1 is available at 8 locations (TM1475) or 12 locations (TM1478)

Figure 2
3. INSTALLATION
A. MOUNT THE 4 X 12 TELECOM DISTRIBUTION MODULE INTO THE ENCLOSURE.
1. Pull out each of the plungers which are located at each corner of the 4 X 12 Telecom Module
2. Insert the module into the included single bay bracket and depress each of the four plungers to secure the
module to the bracket
3. To mount the bracket (with module) into the enclosure, insert the tabs on the left side of the bracket into the
slots in the enclosure and push the bracket pushpin into an appropriate hole in the enclosure to secure the
bracket (with module) to the enclosure

©Copyright 2006 by On-Q/Legrand All Rights Reserved.

Page 1 of 2

INSTRUCTION / INSTALLATION SHEET
• 4 X 12 Telecom Module w/RJ-31x
• 4 X 12 Telecom Module w/RJ-31x &
Configurable Primary Line
301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com

IS-0348 Rev. A

B. TERMINATE WIRING
NOTE: All wiring should be terminated to the T568A wiring standard as shown in Figure 3.
1. Terminate the incoming Cat 5e line from the telephone company NID to the T568A wiring standard.
2. Terminate each Cat 5e line (up to 12 total) that will be used to connect to each voice jack location.
3. Insert the RJ45 connector on the Cat 5e line from the telephone company NID into the RJ45 jack on the
module that is labeled “LINES IN 1,2,3,4”
4. Insert the RJ45 connectors on the Cat 5e lines from the voice outlets into any of the 12 RJ45 jacks on the
module that are labeled “LINES OUT 1,2,3,4”.

Figure 3

C. TERMINATE AND CONFIGURE RJ-31X LINE SEIZURE (OPTIONAL)
NOTE: The following steps MUST be followed to use the Line Seizure option as shown in Figure 4.
1. Terminate a patch cable with a RJ45 on one end and bare-wire connection on the other. Connect the bare-wire
end of the patch cable to the security system according to manufacturer’s instructions. Insert the RJ45
connector end of the cable into the RJ45 jack on the module that is labeled “LINE SEIZURE”.
2. Activate the Line Seizure function on the module by locating the two white dip switches on the module, peeling
off the protective blue tape, and moving both switches upward to the active position.

Figure 4

©Copyright 2006 by On-Q/Legrand All Rights Reserved.

Page 2 of 2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 2
Language                        : EN-US
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:6b404904-96f7-41f5-a7e8-74a9903eb767
Producer                        : Acrobat Distiller 6.0 (Windows)
Keywords                        : 4 X 12 Telecom Module With Configurable Primary Line W/RJ-31x + Surge
Category                        : Instruction/Installation Sheet
Company                         : On-Q/Legrand
Manager                         : Dan Ward
Tag Ad Hoc Review Cycle ID      : -172668496
Tag Email Subject               : New IS
Tag Author Email                : dsowers@onqlegrand.com
Tag Author Email Display Name   : Sowers, Dan
Tag Reviewing Tools Shown Once  : null
Source Modified                 : D:20060621183329
Comments                        : This IS is for the 4 X 12 Telecom Module With Configurable Primary Line W/RJ-31x + Surge  (P/N F1475)
Headline                        : 4 X 12 Telecom Module With Configurable Primary Line W/RJ-31x + Surge
Creator Tool                    : Acrobat PDFMaker 6.0 for Word
Modify Date                     : 2006:06:21 14:34:25-04:00
Create Date                     : 2006:06:21 14:33:55-04:00
Metadata Date                   : 2006:06:21 14:34:25-04:00
Document ID                     : uuid:01500271-9139-4476-8073-ed135f50c4bd
Version ID                      : 96
Format                          : application/pdf
Title                           : IS-0348
Creator                         :  Dan Sowers
Description                     : 4 X 12 Telecom Module With Configurable Primary Line W/RJ-31x + Surge
Subject                         : 4 X 12 Telecom Module With Configurable Primary Line W/RJ-31x + Surge
Tagged PDF                      : Yes
Author                          :  Dan Sowers
EXIF Metadata provided by EXIF.tools

Navigation menu