Schneider Electric Enclosed Safety Switches Brochure

65070-Attachment 65070-Attachment 65070-Attachment 785901 Batch5 unilog cesco-content

2014-07-05

: Pdf 305473-Brochure 305473-Brochure 785901 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 56

Enclosed Safety Switches
Catalog
3100CT0901
2009
Class 3100
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
General Duty Safety Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4
Heavy Duty Safety Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11
Double Throw Safety Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 43
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosed Safety Switches
2
11/2009
© 2009 Schneider Electric
All Rights Reserved
CONTENTS
CATALOG NUMBER DESCRIPTION.................................................................................................... 3
GENERAL DUTY SAFETY SWITCHES ................................................................................................ 4
Product Description .......................................................................................................................... 5
Configuration .............................................................................................................................. 5
Construction ............................................................................................................................... 5
Enclosures........................................................................................................................................ 6
Accessories...................................................................................................................................... 6
Class R Fuse Kits ....................................................................................................................... 6
Fuse Puller Kits .......................................................................................................................... 6
Equipment Grounding Kits.......................................................................................................... 6
Electrical Interlock Kits ............................................................................................................... 7
Field-Installed Lug Kit ................................................................................................................. 7
Class J Fuse Kit.......................................................................................................................... 7
HEAVY DUTY SAFETY SWITCHES ................................................................................................... 11
Product Description ........................................................................................................................ 12
Configuration.................................................................................................................................. 12
Construction ................................................................................................................................... 12
Enclosures...................................................................................................................................... 13
Receptacle Switches...................................................................................................................... 14
Appleton Powertite® Receptacle .............................................................................................. 14
Crouse-Hinds Arktite® Receptacle ........................................................................................... 14
Hubbellock Receptacle .......................................................................................................... 14
Motor Disconnect Switches............................................................................................................ 15
MD50 ........................................................................................................................................ 15
Compliances............................................................................................................................. 15
Application...................................................................................................................................... 16
Standards....................................................................................................................................... 16
General dc and Photovoltaic Systems ........................................................................................... 17
Special Applications ....................................................................................................................... 19
Accessories.................................................................................................................................... 20
Hubs ......................................................................................................................................... 20
Class R Fuse Kits ..................................................................................................................... 20
Solid Neutral Assemblies.......................................................................................................... 20
Equipment Grounding Kits........................................................................................................20
Electrical Interlock Kits ............................................................................................................. 21
Fuse Puller Kits ........................................................................................................................ 21
Optional Compressor Lugs....................................................................................................... 21
Key Interlock System................................................................................................................ 21
Lock-Off Guard ......................................................................................................................... 22
Internal Barrier Kits................................................................................................................... 22
DOUBLE THROW SAFETY SWITCHES............................................................................................. 43
Product Description ........................................................................................................................ 44
Construction ................................................................................................................................... 44
Enclosures...................................................................................................................................... 44
Accessories.................................................................................................................................... 45
NOTE: For information on Replacement Parts with specific part numbers, go to www.schneider-
electric.us, click on Product FAQ’s, enter the device catalog number, click SEARCH, then look for the
information required.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosed Safety Switches
3
11/2009
© 2009 Schneider Electric
All Rights Reserved
Catalog Number Description
Number Segment Character Description D 321NRB —
Type of Switch
Fusible
L=Light duty
D=General duty
H=Heavy duty
DT=Double throw
Non-Fusible
DU=General duty
HU=Heavy duty
DTU=Double throw
Blades–Switchable Poles
11 pole
22 poles
33 poles
4 4 poles
6 6 poles
Voltage Rating1
1 120 Vac (plug fuse)
2 240 Vac
6 600 Vac
Ampere Rating
130 A
260 A
3100 A
4200 A
5400 A
6600 A
7800 A
81200 A
Neutral N Factory-installed neutral (neutrals are field-installed on most general duty, heavy duty,
and double throw safety switches).
Enclosure
No suffix NEMA Type 1
ANEMA Type 12K
AWK NEMA Type 12 (without K.O.)
DF NEMA Type 4X Fiberglass reinforced polyester
DS NEMA Types 4, 4X, and 5 (Type 304 stainless steel)
DX NEMA Type 4X Krydon®
RNEMA Type 3R
RB NEMA Type 3R (bolt-on hub provision)
SS NEMA Types 4, 4X, and 5 (Type 316 stainless steel)
Factory Modifications
CLR Class R fuse kit
EI or EI2 Electrical interlock kit
GL Equipment ground lugs
GLC Equipment ground lug, copper only
KI, KI2 or KIKI 1 or 2 Key interlocks
LK Compression lugs (800 and 1200 A only)
NP Phenolic legend plate
PB Push buttons, pilot lights, selector switches. Customer must provide catalog number of control
device to be installed
SLC Copper lugs (30–600 A)
SP Special paint colors
SPLO Lock-on provision
VW Viewing window
WA Appleton interlocked receptacle
WC Crouse-Hinds Arktite® interlocked receptacle
WH Hubbellock™ interlocked receptacle
1For dc ratings, see the latest catalog listing.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Enclosed Safety Switches
4
11/2009
GENERAL DUTY SAFETY SWITCHES CONTENTS
Product Description ................................................................................5
Configuration ..........................................................................................5
Construction ...........................................................................................5
Enclosures..............................................................................................6
Accessories ............................................................................................6
Class R Fuse Kits .............................................................................6
Fuse Puller Kits.................................................................................6
Equipment Grounding Kits................................................................6
Electrical Interlock Kits......................................................................7
Optional Field-Installed Lug Kit .........................................................7
Class J Fuse Kit................................................................................7
Application and Standards................................................................8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosed Safety Switches
General Duty Safety Switches
5
11/2009
© 2009 Schneider Electric
All Rights Reserved
General Duty Safety Switches
Product Description
General duty safety switches are designed for residential and commercial
applications where durability and economy are a prime consideration.
Typical loads include lighting, air conditioning, and appliances. They are
suitable for use as service equipment when equipped with a factory-
installed neutral assembly or field-installed service grounding kit, as
applicable.
General duty safety switches are UL® Listed, File E2875, and meet or
exceed the NEMA® Standard KS1. The switches are also available with
CSA® rating.
Configuration
Two fusible switched poles with insulated, grounded neutral
Three fusible, switched poles with insulated, grounded neutral
Two or three, not fusible, switched poles without insulated, grounded
neutral
Construction
Indoor NEMA Type 1 or Outdoor NEMA Type 3R enclosures
Visible blades for positive indication that the switch is “OFF”
Quick-make, quick-break operating mechanism
Lugs suitable for aluminum or copper conductors. See page 8 for
additional lug data
Spring reinforced, plated copper fuse clips
Series F handle/lock-plate is a field-replaceable modular design
Series F operating mechanism is an enclosed, field-replaceable,
modular design
Series F NEMA Type 3R covers have side opening construction
Top endwalls in 30–200 A NEMA Type 3R switches have bolt-on hub
provisions
Multiple padlock provisions in “OFF” position
Tangential combination knockouts alleviate the need for offset bends
Visible Blade Construction
Operating Mechanism with Line Base
Series F
Tangential Knockouts
Wall
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosed Safety Switches
General Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
6
11/2009
Enclosures
Enclosures are finished in gray, baked enamel that is electrodeposited on
cleaned, phosphatized steel.
NEMA Type 1 general purpose, indoor
NEMA Type 3R general purpose, outdoor
Accessories
Rainproof Hubs
Bolt-on hubs for rainproof applications. Switches with RB suffix accept
3/4 through 2-1/2 inch bolt-on hubs. Switches with R suffix have blank
endwalls.
Class R Fuse Kits
For systems up to 100,000 rms symmetrical amperes
See page 9 for selection
Fuse Puller Kits
Kit consists of three fuse pullers as required for a 3-pole fusible 60 A or
100 A general duty switch. Kits can be installed into 60 or 100 A Series F
switches.
Equipment Grounding Kits
Aluminum or copper conductors
Field-installed
RB Hub
30 and 60 A
200 A
100 A
Grounding Kits
Table 1: Fuse Puller Kits
Switch Ampere Rating Series Number Fuse Puller Kit Catalog Number
60 F FPK03
100 F FPK0610
Table 2: Equipment Grounding Kits
Switch Ampere
Rating Catalog Number Equipment Grounding Kit
Catalog Number
30, Series E 60 PK3GTA1
(2) 12 Cu or
(2) 10 Al or
(1) 4 Al/Cu Max.
Series F 60 GTK03
(2) 12 Cu or
(2) 10 Al or
(1) 4 Al/Cu Max.
100 GTK0610 (2) 1/0 Al/Cu Max.
200 PK0GTA2 (2) 2/0 Al/Cu Max.
400, 600 PK0GTA2 (Two required) (2) 2/0 Al/Cu Max. Per Lug
800 PK0GTA3 (6) 3/0 Al/Cu Max.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosed Safety Switches
General Duty Safety Switches
7
11/2009
© 2009 Schneider Electric
All Rights Reserved
Electrical Interlock Kits
Electrical interlocks for Series F 100–200 A general duty safety switches
and Series F 60 A fusible general duty safety switches are available in kit
form for field installation. Each kit contains instructions for proper field
mounting. A pivot arm operates from switch mechanism, breaking the
control circuit before the main switch blades break. Switches with electrical
interlocks installed are UL Listed,
Class J Fuse Kit
The Class J Fuse Kit consists of three Class J fuse adapters as required for
a three-pole fusible 600 A general duty switch. Kit can be installed in 600 A
Series E3 switches only (NEMA Type 1).
Table 3: Electrical Interlock Kits
Switch Ampere Rating Electrical Interlock Kit Catalog Number 1
1Electrical interlock kit catalog numbers with -1 suffix indicate one normally open and one
normally closed contact; -2 indicates two normally open and two normally closed contacts. Kits
are UL Listed.
Fusible Series F 60 EIK031 or EIK032
Series F 100–200 EIK-1 or EIK-2
Table 4: Electrical Interlock Contact Ratings 1
1Single-pole single-throw interlock kits are rated 1/2 hp at 110 and 220 Vac.
Interlock Type
AC 50 or 60 Hz DC
Volts Make Break Cont. Volts Make /
Break Cont.
1 N. O. / 1 N. C. Contact
(-1 Suffix 2)
2-1 Suffix uses a 9007A01 limit switch.
120 40.00 A 15.00 A 15.00 A 115 0.50 A 15.00 A
240 20.00 A 10.00 A 15.00 A 230 0.25 A 15.00 A
480 10.00 A 6.00 A 15.00 A
600 8.00 A 5.00 A 15.00 A 600 0.05 A 15.00 A
2 N. O. / 2 N. C. Contacts
(-2 Suffix 3)
3-2 Suffix uses a 9007C03 limit switch.
Optional Field-Installed Lug Kit
Kit consists of three line, three load, and two neutral lugs as required for a
3-pole 400 A or 600 A general duty switch. Kit can be installed on 400 A or
600 A Series E3 switches only.
120 30.00 A 3.00 A 10.00 A 115 1.00 A 10.00 A
240 15.00 A 1.50 A 10.00 A 230 0.30 A 10.00 A
480 7.50 A 0.75 A 10.00 A
600 6.00 A 0.60 A 10.00 A 600 0.10 A 10.00 A
Table 5: Field-Installed Lug Kit
Switch Ampere
Rating
Lug Kit Catalog
Number Wire Range/NEC®Lug Wire Range
400 or 600 Series E3 1
1Not suitable for use on 400 A NEMA Type 3R.
GD4060LK
1-1/0-600 kcmil
2-1/0-500 kcmil
4-1/0-250 kcmil
2-1/0-600 kcmil
4-1/0-250 kcmil
Table 6: Class J Fuse Kit
Switch Ampere Rating Class J Kit Cat. No.
600 A Series E3 GDJK600
Field-Installed Lug Kit for 400 and 600 A Devices
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Enclosed Safety Switches
General Duty Safety Switches
8
11/2009
Application Standards
General duty safety switches are designed for
the following applications:
General duty safety switches are manufactured
in accordance with these standards:
Residential and light commercial applications
Infrequent or moderate operations
240 Vac maximum
Up to 100,000 rms symmetrical amperes,
using appropriately rated Class R fuses and
Class R Fuse Kits, or Class T or J fuses
30—800 A
Horsepower rated
Load-make, load-break rated for the switch
current rating.
UL 98, Standard for Enclosed and Dead
Front Switches. UL Listed under File E2875
NEMA Standards Publication KS1, Enclosed
Switches
Federal Specifications WS-865c for Type
NDS (NEMA Type 1) and Type LD (NEMA
Type 3R)
The light duty enclosed switch is ideal for home
applications in disconnecting power to workshops,
hobby rooms, furnaces and garages.
UL/CSA Listed Short Circuit Current Rating
(RMS Symmetrical)
Light duty—visible blades 10,000 A short
circuit current rating
30 A fusible and non-fusible, 240 Vac
Replacement parts not available
Available with plug or cartridge fuse holders
L211N
NOTE: Switch is load make/break.
Switch Type Fuse Class Short Circuit Rating
Fusible
Plug 10 kA
H 10 kA
J100 kA
R100 kA
T100 kA
Non-Fusible 1
1The UL Listed short-circuit current rating for Square D® general
duty non-fusible switches is based on the switch being used in
conjunction with fuses. Evaluation of non-fusible switches in
conjunction with molded case circuit breakers has not been
performed. If a UL Listed short circuit current rating is required,
this non-fusible switch must be replaced with a Square D general
duty fusible safety switch, equipped with the appropriate class
and size fusing. The UL Listed short circuit current rating of the
fusible switch is typically as follows: when used with Classes H
and K fuses—10 kA, Classes J and R fuses—100 kA. Consult
the wiring diagram of the switch to verify the UL Listed short
circuit current rating.
H 10 kA
J100 kA
R100 kA 2
250 kA for 60 A non-fusible switch.
T100 kA
Table 7: Terminal Lug Data1
130–100 A switches suitable for 60°C or 75°C conductors. 200–800 A switches suitable for 75°C
conductors.
Ampere
Rating
Conductors
Per Phase
Wire Range
Wire Bending Space
Per NEC® Table 312.6
AWG/kcmil
Lug Wire Range
AWG/kcmil
30 1 12–6 (Al) or 14–6 (Cu) 12–6 (Al) or 14–6 (Cu)
60 1 10–3 (Al) or 14–3 (Cu) 10–2 (Al) or 14–2 (Cu)
100 1 12–1 (Al) or 14–1 (Cu) 12–1/0 (Al) or 14–1/0 (Cu)
200 1 6–250 (Al/Cu) 6–300 (Al/Cu)
400
NEMA
Type1
1
or
2
1/0–600 (Al/Cu)
or
1/0–300 (Al/Cu)
(1) 1–750 (Al/Cu)
or
(2) 1/0–300 (Al/Cu)
400
NEMA
Type 3
2 1/0–250 (Al/Cu)
(1) 1/0–600 (Al/Cu)
or
(2) 1/0–250 (Al/Cu)
600 2 4–500 (Al/Cu) 4–600 (Al/Cu)
800 3 3/0–500 (Al/Cu) 3/0–500 (Al/Cu)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Enclosed Safety Switches
General Duty Safety Switches
9
11/2009
© 2009 Schneider Electric
All Rights Reserved
Catalog Number Series
Class R Fuse Kits
Available for
Field-Installation1
1Rejection kits are available for Series D2, E1, E2, and F1 switches. When installed, this kit rejects all but Class R fuses. When installed with this kit and Class R
fuses, the switch is UL Listed for use on systems with up to 100,000 RMS symmetrical amperes available fault current.
Horsepower Ratings
120 Vac 240 Vac 240 Vac
Std. Max. Std. Max.
Catalog Number 1Ø 1Ø 1Ø 3Ø 1Ø 3Ø
L111N
L211N
L221N
E2 N/A 1/2
2
2 2
2 2
2For corner grounded delta systems only, use switching poles for ungrounded conductors.
1-1/2 2
1-1/2 2
3
3 3
3 3
3Suitable for use as service equipment; requires field installation of a service grounding kit (see Digest 175, page 3-5). Solid neutral assembly for Series F is SN20A
for the DU324 or DU324RB.
D211N
D211NRB
E3
E2 N/A 1/2 21-1/2 — 3 —
D221N
D221NRB E3 DRK30 1-1/2
1-1/2
3 3
3 33
3
7-1/2 3
7-1/2 3
D222N
D222NRB F1 RFK03L 1-1/2 3 3 7-1/2 310 15 3
D223N
D223NRB F3 RFK10 7-1/2 7-1/2 15 315 30 3
D224N 4
D224NRB 4
4For 200% neutral, order (1) additional neutral kit SN20A and (1) neutral jumper kit SN20NI.
F1 HRK1020 15 15 25 3 60 3
D225N E3 DRK40 ——————
D225NR E1 ——————
D226N E3 DRK600 ——————
D226NR E1 DRK600 ——————
D321N
D321NRB E3 DRK30 — 1-1/2 3 3 7-1/2
D322N
D322NRB F1 RFK03L 1-1/2 3 3 7-1/2 10 15
D323N F3 RFK10 7-1/2 15 15 30
D323NRB 7-1/2 15 15 30
D324N 4
F1 HRK1020 15 25 60 2
D324NRB 4 15 25 60 2
D325N E3 DRK40 — — — 50 125
D325NT — — — 50 — —
DRK325NR E1 DRK40 ———50 125
DRK325NTR — — — 50 — —
D326N E3 DRK600 ———75 150
D326NT — — — 75 — —
D326NR E1 DRK600 — — — 75 150
D326NTR — — — 75 — —
DU221RB 3E2 — ————1015
DU222RB 5
5Suitable for use as service equipment; requires field installation of solid neutral assembly D600SN.
E1 — ————1015
DU323 4
DU323RB 4F3 — ————15 30
DU324 4
DU324RB 4F1 — ————25 60
DU325 4
E3 — —————125
DU326 4— —————150
QO200TR 6 7 8
QO260NATS 7 9
QO2000NRB
QO2000NS
6Includes factory-installed neutral.
7Includes factory-installed grounding kit.
8Not service entrance rated.
9Enclosed molded case switch.
G3
E2
E1
E1
10
10
20
20
T327N
T327NR E1
100
100
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Enclosed Safety Switches
General Duty Safety Switches
10
11/2009
W
W / H D
Typical NEMA Type 1
W
D
W / H
Typical NEMA Type 3R
H
Table 8: Switch Dimensions
Catalog
Number Series
H W W/H D
in. mm in. mm in. mm in. mm
L111N 1
1Does not have a cover draw as indicated in above drawing.
E2 7.63 194 5.00 127 6.13 156 4.00 102
L211N 1E2 7.63 194 5.00 127 6.13 156 4.00 102
L221N 1E2 7.63 194 5.00 127 6.13 156 4.00 102
D211N 1E3 9.25 235 6.75 171 7.25 184 3.63 92
D211NRB 1E2 9.63 245 7.25 184 7.75 197 3.75 95
D221N 1E3 9.25 235 6.75 171 7.25 184 3.63 92
D221NRB 1E3 9.63 245 7.25 184 7.75 197 3.75 95
D222N F1 14.60 371 6.51 165 7.45 189 4.87 124
D222NRB F1 14.88 378 6.63 168 7.45 189 4.87 124
D223N F3 17.50 445 8.50 216 10.50 267 6.50 165
D223NRB F3 17.50 445 8.50 216 10.50 267 6.50 165
D224N F1 29.00 737 17.25 438 19.00 483 8.25 210
D224NRB F1 29.25 743 17.25 438 19.00 483 8.25 210
D225N E3 45.12 1146 24.00 610 24.88 632 8.88 226
D225NR E3 30.63 778 21.38 543 22.25 565 10.13 257
D226N 1E3 49.13 1248 24.00 610 24.88 632 8.88 226
D226NR 1E3 49.13 1248 24.75 629 25.13 638 8.88 226
D321N 1E3 9.25 235 6.75 171 7.25 184 3.63 92
D321NRB 1E3 9.63 245 7.25 184 7.75 197 3.75 95
D322N F1 14.60 371 6.51 165 7.45 189 4.87 124
D322NRB F1 14.88 378 6.63 168 7.45 189 4.87 124
D323N F3 17.50 445 8.50 216 10.50 267 6.50 165
D323NRB F3 17.50 445 8.50 216 10.50 267 6.50 165
D324N F1 29.00 737 17.25 438 19.00 483 8.25 210
D324NRB F1 29.25 743 17.25 438 19.00 483 8.25 210
D325N 1E3 45.12 1146 24.00 610 24.88 632 8.88 226
D325NT 1E3 45.12 1146 24.00 610 24.88 632 8.88 226
D325NR E1 30.63 778 21.38 543 22.25 565 10.13 257
D325NTR E1 30.63 778 21.38 543 22.25 565 10.13 257
D326N 1E3 49.13 1248 24.00 610 24.88 632 8.88 226
D326NT 1E3 49.13 1248 24.00 610 24.88 632 8.88 226
D326NR E1 49.13 1248 24.75 629 25.13 638 8.88 226
D326NTR E1 49.13 1248 24.75 629 25.13 638 8.88 226
DU221RB 1E2 9.63 245 7.25 184 7.75 197 3.75 95
DU222RB 1E1 9.63 245 7.25 184 7.75 197 3.75 95
DU321 1E2 9.25 235 6.75 171 7.25 184 3.63 92
DU321RB 1E2 9.63 245 7.25 184 7.75 197 3.75 95
DU322 1E1 9.25 235 6.75 171 7.25 184 3.63 92
DU322RB 1E1 9.63 245 7.25 184 7.75 197 3.75 95
DU323 F1 17.50 445 8.50 216 10.50 267 6.50 165
DU323RB F1 17.50 445 8.50 216 10.50 267 6.50 165
DU324 F1 29.00 737 17.25 438 19.00 483 8.25 210
DU324RB F1 29.25 743 17.25 438 19.00 483 8.25 210
DU325 1E3 45.12 1146 24.00 610 24.88 632 8.88 226
DU326 1E3 49.13 1248 24.00 610 24.88 632 8.88 226
QO200TR 1G3 6.50 165 4.63 118 3.88 99
QO260NATS E2 9.25 235 4.88 124 3.25 83
QO2000NRB E1 14.00 356 7.75 197 4.50 114
QO2000NS 1E1 13.38 340 6.13 156 3.50 89
T327N 1E1 49.13 1248 24.00 610 24.88 632 8.88 226
T327NR 1E1 49.13 1248 24.75 629 25.13 638 8.88 226
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
11
11/2009
© 2009 Schneider Electric
All Rights Reserved
HEAVY DUTY SAFETY SWITCHES CONTENTS
Product Description..............................................................................12
Configuration ..................................................................................12
Construction ...................................................................................12
Enclosures............................................................................................13
Receptacle Switches............................................................................14
Appleton Powertite® Receptacle ....................................................14
Crouse-Hinds Arktite® Receptacle .................................................14
Hubbellock Receptacle.................................................................14
Motor Disconnect Switches ..................................................................15
MD50 ..............................................................................................15
Applications..........................................................................................16
Standards.............................................................................................16
General dc and Photovoltaic Systems .................................................17
Special Applications .............................................................................19
Accessories ..........................................................................................20
Hubs ...............................................................................................20
Class R Fuse Kits ...........................................................................20
Solid Neutral Assemblies................................................................20
Equipment Grounding Kits..............................................................20
Electrical Interlock Kits ...................................................................21
Fuse Puller Kits ..............................................................................21
Optional Compression Lugs ...........................................................21
Key Interlock System......................................................................21
Lock-Off Guard ...............................................................................22
Internal Barrier Kits.........................................................................22
General Information..............................................................................28
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
12
11/2009
Product Description
The Square D® brand Heavy Duty Safety Switch is designed to be tough,
reliable and provide exceptional performance in the most grueling
conditions; from commercial and institutional to industrial and manufacturing
facilities. Square D F Series safety switches provide significantly higher
levels of mechanical endurance than NEMA KS-1 requires. The design life
of a Square D F-Series switch is a minimum of three times the NEMA
requirement.
An abundance of copper is used in the heaviest current carrying power
paths of all Square D Heavy Duty Safety Switches. The more copper for
current carrying paths, the lower the temperature rise. Managing
temperatures inside the switch is the key to providing greater service life.
All heavy duty safety switches feature a quick-make, quick-break operating
mechanism, a dual cover interlock and a color-coded indicator handle.
Configuration
Two or three fusible switched poles with or without insulated, solid
grounded neutral
Four or six fusible switched poles without insulated, solid grounded
neutral
Two, three, four or six non-fusible, switched poles without insulated,
solid grounded neutral
Three fusible switched poles without insulated solid grounded neutral
interlocked to Appleton®, Crouse-Hinds®, or Hubbellock receptacle
Three non-fusible switched poles without insulated solid grounded
neutral interlocked to Appleton, Crouse-Hinds, or Hubbellock receptacle
Construction
Visible blades for positive blade position indication
Optional viewing window allows visual verification of blade position
without opening door; not available on NEMA Type 4X fiberglass
reinforced polyester or Krydon® enclosures or NEMA Type 7 or 9
enclosures
Red and black handle indication for switch position
Series F handle, mechanism, and lock plate are field replaceable
Series F Type 3R devices have side-opening covers
Highly visible embossed ON-OFF marking
Quick-make, quick-break, spring-driven operating mechanism
Front removable mechanical lugs. Refer to page 28 for further lug data
Standard lugs accommodate aluminum or copper cable termination
Optional lugs accommodate copper only cable termination
Series F
Operating Mechanism
Series F
Mechanical Lugs
Visible Blades
NEMA Type 1 NEMA Type 3R NEMA Types 4, 4X, and 5
Stainless Steel NEMA Type 12
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
13
11/2009
© 2009 Schneider Electric
All Rights Reserved
Dual cover interlock keeps the cover closed when switch is ON. When
the cover is open, it interlocks the switch OFF, unless the interlock is
bypassed.
Factory-installed fuse pullers on 30–100 A NEMA Types 4, 4X, and 5
stainless steel, NEMA Type 4X fiberglass reinforced polyester, Krydon and
NEMA Types 12 or 12K switches. Available for field installation on
30–100 A F Series switches, NEMA Types 1 and 3R switches.
Class J fuse provisions on 30 A–600 A, 600 V switches and
100–600 A, 240 V switches. 600 A devices require a mounting kit
(catalog number H600J).
30–600 A switches are shipped with standard Class H fuse spacing.
These switches will accept Class R fuses also. A field-installable
rejection kit is available, which, when installed, rejects all but Class R
fuses. See pages 23 through 26 for Class R fuse kits.
Multiple padlock provision in OFF position (three padlocks).
Lock-on provisions for factory or field modification.
Tangential combination knockouts lessen the need for conduit offset
bends.
Enclosures
NEMA Type 1 general purpose, indoor
NEMA Type 3R rainproof, outdoor
NEMA Types 4, 4X, 5 indoor or outdoor, watertight, dust-tight, and
corrosion-resistant (Types 304 and 316 stainless steel)
NEMA Type 4X indoor or outdoor, watertight and dust-tight, and
corrosion-resistant (fiberglass reinforced polyester)
NEMA Types 7 and 9 hazardous locations:
Class I, Groups C and D
Class II, Groups E, F and G
Class III
NEMA Types 12 and12K indoor, dust-tight, and drip-proof
NEMA Type 12 has no knockouts (suitable for outdoor use)
NEMA Type 12K provided with knockouts
Fuse Pullers
Class J Fuse Provisions
Alternate mounting holes make for easy
conversion to Class J fuses.
Wall
Tangential Knockouts
Lock-off Provision with Optional
Lock-off Guard Kit Installed
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
14
11/2009
Receptacle Switches
Interlocked receptacle switches are furnished with a factory-installed three-
phase four-wire Appleton Powertite®, Crouse-Hinds Style 2 Arktite®, or
Hubbellock receptacle. The fourth wire is connected to the switch equipment
grounding terminal and is not a solid neutral termination. Interlocking linkage
between the receptacle and switch mechanism prevents insertion or removal of
the plug while the switch is in the “ON’’ position, or insertion of any plug other
than specified. The interlocking mechanism also prevents the switch from being
turned “ON” if a plug has not been fully inserted into the receptacle.
Appleton Powertite® Receptacle
Devices are UL Listed and CSA Certified, suitable for use as service
equipment
Receptacles are epoxy powder coated over copper-free cast aluminum
60 A, H362AWA and HU362AWA are stock items. All other items are
non-stock and require an 8-week lead time
Short circuit rating: 10 kA when used with or protected by Class H or K
fuses; 200 kA when used in conjunction with Class R, T, or J fuses
Crouse-Hinds Arktite® Receptacle
Devices are UL Listed and suitable for use as service equipment
60 A, H362AWC and HU362AWC are stock items. All other items are
non-stock and require a 12-week lead time
Short circuit rating: 10,000 A when used with or protected by Class H or
K fuses; 200,000 A when used in conjunction with Class R, T or J fuses
Hubbellock Receptacle
UL Listed and suitable for use as service equipment
Short circuit rating: 10 kA
H362AWA Interlocked Receptacle Switch
with Appleton Powertite Receptacle
H362AWC Interlocked Receptacle Switch
with Crouse-Hinds Arktite Receptacle
H362AWH Interlocked Receptacle Switch
with Hubbellock Receptacle
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
15
11/2009
© 2009 Schneider Electric
All Rights Reserved
Motor Disconnect Switches
Square D®, a brand of Schneider Electric®, brings to the market a
comprehensive offering of Motor Disconnect switches listed UL508
"Suitable as Motor Disconnect". The MD50 IEC60309 mechanical interlock
receptacle switches address fixed and flexible process requirements.
MD50
The MD50 motor disconnect is a pin and sleeve interlocked switch
receptacle listed UL 508 "Suitable As Motor Disconnect" in one compact
Type 4X enclosure. It is offered in 20, 30, 60, and 100 A units compatible
with IEC60309-2 plug configurations.
The MD50 UL 508 switch with receptacle interlock allows motor driven
equipment and motors to be moved into and out of a given space when
necessary. Plus, a key safety feature is that the interlock switch design
requires an operator to turn off the load before removing the machine plug
from the receptacle.
Compliances
UL Listed 98 File Number E2875 and E317818
UL Listed 508–Industrial Control Equipment
UL Listed 1682 and 1686–Plugs and Receptacles, Pin and Sleeve Type
CSA Certified 22.2 No. 4-M91 File Number E243232
IEC 60309-1; IEC 60309-2
Enclosure: plastic Types 4X and 12
UL 94 – 5 V Flame Rating
UV Stabilized Material
IP66
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
16
11/2009
Applications
Heavy duty safety switches are designed for the following applications:
Commercial and industrial installations
Up to 600 Vac or 600 V dc maximum
Up to 200,000 rms symmetrical amperes short circuit current
30—1200 A
Horsepower ratings
Load-make, load-break rated for the switch current rating
Two or three fusible switched poles with or without insulated, grounded
neutral
Four or six fusible switched poles, neutral not available
Two or three non-fusible, switched poles with or without insulated,
grounded neutral
Four non-fusible switched poles, neutral not available
Six non-fusible switched poles, neutral not available
Tested and approved for seismic applications
Standards
Heavy duty safety switches are manufactured in accordance with these
standards:
UL98, Standard for Enclosed and Dead Front Switches. UL Listed under
File E2875, or E154828
NEMA Standards Publication KS1, Enclosed Switches
Federal Specifications WS-865c for Type HD
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
17
11/2009
© 2009 Schneider Electric
All Rights Reserved
General dc and Photovoltaic Systems
As a market leader and innovator in photovoltaic (PV) applications, we are
proud to announce a catalog section dedicated to dc and PV safety switch
applications. This section focuses on the Square D® brand UL approved Heavy
Duty Safety Switch dc and PV wiring schemes. Additionally a UL witnessed and
Square D self-certified PV wiring option is presented. This additional unlisted
option provides a robust, cost effective option for PV systems.
All heavy duty safety switches with dc ratings (2-, 3- and 4-pole fusible and non-
fusible) are Underwriters Laboratories (UL) Listed and CSA Certified for use on
dc applications when wired as shown in Figure 1 (A, B, C, D, E, and F). UL
Listed, CSA Certified (Files E2875 and E154282). Additionally:
Heavy duty safety switches are rated for 600 Vdc maximum open circuit
voltage.
Non-fusible safety switches may carry 100 percent of the nameplate
current rating.
Fusible safety switches may carry 80 percent of nameplate current
rating (continuous use).
Heavy duty switches are dc horsepower rated as indicated on the safety
switch wiring diagram.
Heavy duty switches have a 10,000 ampere dc short-circuit rating at 600
Vdc unless otherwise stated on the switch wiring diagram. Consult
factory for short circuit current ratings at 250 Vdc.
Refer to current Square D Digest for lug wire range of heavy duty
switches.
Figure 1: General dc and Photovoltaic Systems, Fusible and Non-Fusible Wiring Diagram
NOTE: Heavy duty safety switches may be used
on photovoltaic systems with a grounded feed.
Refer to Figures 1B, 1D, 1F and 2 (negative
grounding shown; positive grounded systems are
similarly allowed). For ungrounded systems, see
National Electrical Code® (NEC®) 690.35 (NEC
2008, NFPA 70).
A
600 Vdc
B
600 Vdc
LOAD
LINE
LOAD
LINE
C
LOAD
LINE 600 Vdc
(Non-Fusible Shown)
D
LOAD
LINE 600 Vdc
(Two-Pole)
(Two-Pole)
(Four-Pole)
(Three-Pole)
(Three-Pole)
LOAD LOAD
E
F
600 Vdc
LINE
(Four-Pole)
LOAD
LOAD
600 Vdc
LINE
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
18
11/2009
Alternate Photovoltaic System Wiring, Evaluated and
Self-Certified by Schneider Electric (Not UL Listed)
Figure 2: Grounded Feed per NEC Article 690
Connect negative photovoltaic line (-) to case inside inverter for negative
grounded system.
Positive grounded systems are similarly allowed.
For ungrounded systems, see NEC 690.35 (NEC2008, NFPA70).
If a non-fusible disconnect is used, the inverter must not be capable of
backfeeding currents into a short circuit or fault in the photovoltaic array
or string.
One inverter may be connected to each pole of the switch.
Refer to current Square D Digest for lug wire range of heavy duty
switches.
Current Ratings
Switch Nameplate
600 V
Switch dc Rating
per Pole 1
1The switch per pole rating must be at least the photovoltaic maximum circuit current multiplied
by 125%.
Photovoltaic
Maximum Circuit
Current 2
2From NEC 2008 and NFPA 70, Article 690.8: the photovoltaic maximum circuit current is Isc
multiplied by 125%.
Photovoltaic
Short-Circuit
Current (lsc)
30 A 20 A 16 A dc per pole 12.8 A (20/1.56)
60 A 60 A 48 A dc per pole 38 A (60/1.56)
100 A 100 A 80 A dc per pole 64 A (100/1.56)
(((
((((
(((
)))
)))
))))
Photovoltaic Array
or String
Max Open Circuit
Voltage 600 Vdc
30–100 A, 600 V
Fusible or
Non- Fusible
Disconnect
(Fusible Shown)
(To Inverter)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
19
11/2009
© 2009 Schneider Electric
All Rights Reserved
Special Applications
Rainproof Bolt-On Hubs
Electrical Interlock Kits
Available factory- or field-installed
Pivot arm operates from switch mechanism, breaking the control
circuit before the main switch blades break
Switches with electrical interlocks installed are UL Listed
Watertight Hubs
Class R Fuse Kits
Internal Barrier Kits
Provide an additional barrier that helps prevent accidental contact
with live parts
Field-installed transparent barriers do not restrict visual inspection of
the switch
Barriers provide IEC529 IP2X “finger safe” protection when door of
enclosed disconnect switch is open
Convenient door allows use of test probes without accessing fuses
Allows for replacement of fuses without removing barrier
NOTE: Barrier can also be used with a skirt kit to enclose a panel
mounted Type 9422 disconnect.
Key Interlock Systems
Factory-installed only
Interlocks are used to prevent the authorized operator from making
an unauthorized operation
Not available on hazardous location devices (NEMA Types 7 or 9) or
fiberglass reinforced polyester (NEMA Type 4X)
UL Listed
Lock-On Provisions
Provision for one 3/8 in. hasp padlock is available factory-installed
on NEMA Types 1, 3R, 4, 4X and 5 stainless steel and 12 switches
This modification will allow the switch to be locked in the “ON”
position
UL Listed
Special Paint
Available painted with special safety colors: safety red, safety
orange, safety yellow, safety green, safety blue, safety purple, black
or white
All colors comply with OSHA Standard 1910.144 and ANSI
Specification Z535.1 for marking physical hazards
Phenolic Legend Plate
Available engraved and mounted on all heavy duty safety switches,
except NEMA Types 7 and 9
Legend engraved in 1/4 in. high white letters on black background
Customer must provide legend
UL Listed
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
20
11/2009
Accessories
Square D brand heavy duty safety switches manufactured by Schneider
Electric are UL Listed for use with the following accessories:
Hubs
Bolt-on hubs for rainproof applications. Switches with RB suffix accept 3/4 in.
through 2-1/2 in. bolt-on hubs. Switches with R suffix have blank top endwalls.
NEMA Type 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap
factory-installed. Order bolt-on hubs separately from table above. Hubs through size 2-1/2 in.
can be directly installed on RB devices. Devices requiring 3 in. or larger hubs must have holes
cut in the field. Gaskets are provided on 3 in. and larger hubs. All hubs are UL Listed for indoor
and rainproof applications and suitable for use with conduit having ANSI standard taper pipe
thread.
Watertight hubs are zinc or chrome plated for field-installation on NEMA Types
3R, 4, 4X, 5, and 12 stainless steel switches and Type 12 enclosures.
Class R Fuse Kits
For systems up to 200,000 rms symmetrical amperes provide rejection for
all other fuse types. See pages 23 through 27 for catalog numbers.
Solid Neutral Assemblies
Factory or field-installed insulated, grounded solid neutral assemblies. See
pages 23 through 26 for catalog numbers.
Equipment Grounding Kits
Equipment grounding kits available for factory- or field-installation. See
pages 23 through 26 for catalog numbers.
Bolt-On Hubs
Watertight Hubs
Class R Fuse Kits
Table 9: Rainproof Bolt-On Hubs—For Use on NEMA Type 3R
Enclosures
Conduit
Size 3/4 11-1/4 1-1/2 22-1/2 33-1/2 4Closing
Cap
Hub Cat.
Number B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP
Table 10: Watertight Hubs
Conduit
Trade Size 1/2 3/4 11-1/4 1-1/2 22-1/2 33-1/2 4
Standard
Zinc Hub
Cat. Number
H050 H075 H100 H125 H150 H200 H250 H300 H350 H400
Chrome
Plated Hub
Cat. Number
H050CP H075CP H100CP H125CP H150CP H200CP
Field-installed
Insulated, Grounded Neutral
Field-installed
Equipment Grounding Kit
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
21
11/2009
© 2009 Schneider Electric
All Rights Reserved
Electrical Interlock Kits
Electrical interlocks for heavy duty safety switches through 1200 A are
available factory installed or in kit form for field installation. A pivot arm
operates from the switch mechanism, breaking the control circuit before the
main switch blades break. Switches with electrical interlock accessories
installed are UL Listed. See pages 23 through 26 for catalog numbers.
Fuse Puller Kits
Kit consists of three fuse pullers as required for a three-pole fusible 240 V or
600 V heavy duty switch. Kits can be installed in switches manufactured after
February, 1980. Fuse pullers are supplied as standard equipment on NEMA
Types 12 and 12K; NEMA Types 4, 4X, 5 stainless steel; NEMA Type 4X
fiberglass reinforced polyester, and Krydon® switches through 100 A. See
pages 23 through 26 for catalog numbers.
Optional Compression Lugs
Refer to page 28 for applicable options.
Key Interlock System
Interlocks are used to prevent the authorized operator from making an
unauthorized operation. The key interlock system is a simple and easy
method of applying individual key interlock units and assemblies to the
above equipment so as to require operation in a predetermined sequence.
UL Listed.
They are not available on hazardous location devices (NEMA Types 7 or 9)
or fiberglass reinforced polyester (NEMA Type 4X).
Use these suffixes on switch catalog numbers:
KI = 1 lock per switch
KI2 = 1 lock with 2 cylinders per switch
KIKI = 2 separate locks per switch
NOTE: Factory-installed only on heavy duty safety switches.
Key Interlock System
Table 11: Electrical Interlock Contact Ratings 1
1Single-pole single-throw interlock kits are rated 1/2 hp at 110 and 220 Vac.
-1 Suffix uses a 9007A01 limit switch.
-2 Suffix uses a 9007C03 limit switch.
Interlock
Type
ac 50 or 60 Hz dc
Volts Make Break Cont. Volts Make and
Break Cont.
1 N.O./
1 N.C
Contact
(-1 Suffix)
120
240
480
600
40.0 A
20.0 A
10.0 A
8.0 A
15.0 A
10.0 A
6.0 A
5.0 A
15.0 A
15.0 A
15.0 A
15.0 A
115
230
600
0.50 A
0.25 A
0.05 A
15.0 A
15.0 A
15.0 A
2 N.O./
2 N.C
Contact
(-2 Suffix)
120
240
480
600
30.0 A
15.0 A
7.5 A
6.0 A
3.0 A
1.5 A
0.75 A
0.60 A
10.0 A
10.0 A
10.0 A
10.0 A
115
230
600
1.00 A
0.30 A
0.10 A
10.0 A
10.0 A
10.0 A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
22
11/2009
Lock-Off Guard
Available field-installed only, the lock-off guard works by covering the
lockout/tagout opening whenever the switch is in the ON position. This prevents
a padlock from being inadvertently inserted into the switch lockplate. The
device is designed to help prevent accidental misapplication of a lockout
device. These kits are marked cURus (UL Component Recognized) for field-
installation.
Internal Barrier Kits
Internal Barrier Kits provide an additional barrier that helps prevent accidental
contact with live parts. Field-installed transparent barriers do not restrict visual
inspection of the switch. Barriers provide IEC529 IP2X “finger safe” protection
when door of enclosed disconnect switch is open. Convenient door allows use
of test probes without accessing fuses and replacement of fuses without
removing barrier. Barrier can also be used with the skirt kit to enclose a panel
mounted Type 9422 disconnect.
Lock-Off Guard Shown
Internal Barrier
Table 12: Lock-Off Guard Applications
Switch Rating Kit Catalog Number
30 A LOGK1
60 A 240 V
60 A 600 V LOGK2
100 and 200 A
Table 13: Internal Barrier Kits
Catalog
Number Description Safety Switch Application
(F Series Only)
9422 Type T
Disconnect Application
SS03 Interior Barrier for 30 A
Safety Switch1
1Requires arc shield on 240 V switches be changed to 600 V arc suppressor.
240 / 600 Vac – 30 A NA
240 Vac – 60 A
SS06
Interior Barrier for 60 A
Safety Switch, 30 or
60 A 9422 Switch
600 Vac – 60 A
600 Vac – 30 A
600 Vac – 60 A
SS10
Interior Barrier for 100 A
Safety Switch or
100 A 9422 Switch
240 / 600 Vac – 100 A 600 Vac – 100 A
SS20 Interior Barrier for 200 A
Safety Switch 240 / 600 Vac – 200 A NA
SS0306SK
Skirt Kit to Enclose 30 or
60 A 9422 Switch
(requires SS06)
NA
600 Vac – 30 A
600 Vac – 60 A
SS10SK
Skirt Kit to Enclose 100 A
9422 Switch
(requires SS10)
NA 600 Vac – 100 A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
23
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 14: Accessories for Current Series Heavy Duty Safety Switches
Catalog
Number Series
Electrical
Interlock
(1 Contact)
Electrical
Interlocks
(2 Contacts)
Class R Kits
Solid
Neutral
(Al/Cu)
Solid
Neutral
(Cu Only)
Grounding
Kit
(Al)
Grounding
Kit
(Cu)
Fuse Puller Receptacle
Plugs
H100XFA
H221A
H221AWK
H221DS
E1
F6
F6
F6
N/A
EIK031
EIK031
EK3001
N/A
EIK032
EIK032
EK3002
N/A
RFK03L
RFK03L
HRK30
100SN
SN03
SN03
H60SN
N/A
SN03C
SN03C
H60SNC
Std.
GTK03
GTK03
PK3GTA1
Std.
GTK03C
GTK03C
PKO6GTC1
N/A
Std.
Std.
Std.
N/A
N/A
N/A
N/A
H221N
H221NRB
H222A
H222AWK
F5
F5
F6
F6
EIK031
EIK031
EIK031
EIK031
EIK032
EIK032
EIK032
EIK032
RFK03L
RFK03L
RFK03L
RFK03L
Std.
Std.
SN03
SN03
SN03C
SN03C
SN03C
SN03C
GTK03
GTK03
GTK03
GTK03
GTK03C
GTK03C
GTK03C
GTK03C
FPK03
FPK03
Std.
Std.
N/A
N/A
N/A
N/A
H222DS
H222N
H222NRB
H223A
F6
F5
F5
F6
EIK3061
EIK031
EIK031
EIK1
EIK3062
EIK032
EIK032
EIK2
HRK60
RFK03L
RFK03L
RFK10
H60SN
Std.
Std.
SN0610
H60SNC
SN03C
SN03C
SN0610C
PK3GTA1
GTK03
GTK03
GTK0610
PKOGTC1
GTK03C
GTK03C
GTK0610C
Std.
FPK03
FPK03
Std.
N/A
N/A
N/A
N/A
H223AWK
H223DS
H223N
H223NRB
F6
F6
F5
F5
EIK1
EIK10201
EIK1
EIK1
EIK2
EIK10202
EIK2
EIK2
RFK10
HRK1020
RFK10
RFK10
SN0610
H100SN
Std.
Std.
SN0610C
H100SNC
SN0610C
SN0610C
GTK0610
PKOGTA2
GTK0610
GTK0610
GTK0610C
PKOGTA2
GTK0610C
GTK0610C
Std.
Std.
FPK0610
FPK0610
N/A
N/A
N/A
N/A
H224A
H224AWK
H224DS
H224N
F6
F6
F6
F5
EIK10201
EIK10201
EIK10201
EIK10201
EIK10202
EIK10202
EIK10202
EIK10202
HRK1020
HRK1020
HRK1020
HRK1020
H200SN
H200SN
H200SN
Std.
H200SNC
H200SNC
H200SNC
H200SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC2
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H224NRB
H225
H225AWK
H225DS
F5
E4
E4
E2
EIK10201
EIK40601
EIK40601
EIK40601
EIK10202
EIK40602
EIK40602
EIK40602
HRK1020
HRK4060
HRK4060
HRK4060
Std.
H600SN
H600SN
H600SN
H200SNC
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC2
PKOGTC2
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H225N
H225NAWK
H225NDS
H225NR
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
Std.
H600SN
H600SN
Std.
H600SNC
Std.
Std.
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
N/A
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H225R
H225XKA
H226
H226AWK
E4
C2
E4
E4
EIK40601
N/A
EIK40601
EIK40601
EIK40602
N/A
EIK40602
EIK40602
HRK4060
N/A
HRK4060
HRK4060
H600SN
225SNA
H600SN
H600SN
H600SNC
N/A
H600SNC
H600SNC
PKOGTA2
Std.
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H226DS
H226N
H226AWK
H226NDS
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
Std.
H600SN
H600SN
H600SNC
H600SNC
N/A
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H226NR
H226R
H227
H227AWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
N/A
N/A
Std.
H600SN
H800SNE4
H800SNE4
H600SNC
H600SNC
N/A
N/A
PKOGTA2
PKOGTA2
PKOGTA7
PKOGTA7
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H227N
H227NAWK
H227NR
H227R
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
Std.
Std.
Std.
H800SNE4
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA7
PKOGTA7
PKOGTA7
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H228
H228AWK
H228N
H228NAWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H1200SNE4
H1200SNE4
Std.
Std.
N/A
Std.
N/A
N/A
PKOGTA8
PKOGTA8
PKOGTA8
PKOGTA8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H228NR
H228R
H265
H265AWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
HRK4060
HRK4060
Std.
H1200SNE4
H600SN
H600SN
N/A
N/A
H600SNC
H600SNC
PKOGTA8
PKOGTA8
PKOGTA2
PKOGTA2
N/A
N/A
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H265DS
H265R
H266
H266A
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
H600SN
H600SN
H600SN
H600SNC
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H266AWK
H266DS
H266R
H267
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
Std.
H600SN
H600SN
H600SN
H800SNE4
H600SNC
H600SNC
H600SNC
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA7
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H267AWK
H267NAWK
H267R
H268
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H800SNE4
H800SNE4
Std.
H1200SNE4
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA7
PKOGTA7
PKOGTA7
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H268AWK
H268NAWK
H268R
H321A
E4
E4
E4
F6
EIK40601
EIK40601
EIK40601
EIK031
EIK40602
EIK40602
EIK40602
EIK032
N/A
N/A
N/A
RFK03L
H1200SNE4
Std.
H1200NE4
SN03
N/A
N/A
N/A
SN03C
PKOGTA7
PKOGTA7
PKOGTA7
GTK03
N/A
N/A
N/A
GTK03C
N/A
N/A
N/A
Std.
N/A
N/A
N/A
N/A
H321AWK
H321DS
H321N
H321NRB
F6
F6
F5
F5
EIK031
EIK3001
EIK031
EIK031
EIK032
EIK3002
EIK032
EIK032
RFK03L
HRK30
RFK03L
RFK03L
SN03
H60SN
Std.
Std.
SN03C
H60SNC
SN03C
SN03C
GTK03
PK3GTA1
GTK03
GTK03
GTK03C
PKOGTC1
GTK03C
GTK03C
Std.
Std.
FPK03
FPK03
N/A
N/A
N/A
N/A
Continued on next page
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
24
11/2009
Table 14: Accessories for Current Series Heavy Duty Safety Switches
Catalog
Number Series
Electrical
Interlock
(1 Contact)
Electrical
Interlocks
(2 Contacts)
Class R Kits
Solid
Neutral
(Al/Cu)
Solid
Neutral
(Cu Only)
Grounding
Kit
(Al)
Grounding
Kit
(Cu)
Fuse Puller Receptacle
Plugs
H322A
H322AWK
H322DS
H322N
F6
F6
F6
F5
EIK031
EIK031
EK3061
EIK031
EIK032
EIK032
EIK3062
EK032
RFK03L
RFK03L
HRK30
RFK03L
SN03
SN03
H60SN
Std.
SN03C
SN03C
H360SNC
SN03C
GTK03
GTK03
PK3GTA1
GTK03
Std.
GTK03C
GTK03C
PKO6GTC1
Std.
Std.
Std.
FPK03
N/A
N/A
N/A
N/A
H322NRB
H323A
H323AWK
H323DS
F5
F6
F6
F6
EIK031
EIK1
EIK1
EK10201
EIK032
EIK2
EIK2
EIK10202
RFK03L
RFK10
RFK10
HRK1020
Std.
SN0610
SN0610
H100SN
SN03C
SN0610C
SN0610C
H100SNC
GTK03
GTK0610
GTK0610
PKOGTA2
GTK03C
GTK0610C
GTK0610C
PKOGTC2
FPK03
Std.
Std.
Std.
N/A
N/A
N/A
N/A
H323N
H323NRB
H324A
H324AWK
F5
F5
F6
F6
EIK1
EIK1
EK10201
EK10201
EIK2
EIK2
EIK10202
EIK10202
RFK10
RFK10
HRK1020
HRK1020
Std.
Std.
H200SN
H200SN
SN0610C
SN0610C
H200SNC
H200SNC
GTK0610
GTK0610
PKOGTA2
PKOGTA2
GTK0610C
GTK0610C
PKOGTC2
PKOGTC2
FPK0610
FPK0610
N/A
N/A
N/A
N/A
N/A
N/A
H324DS
H324N
H324NRB
H325
F6
F5
F5
E4
EK10201
EK10201
EK10201
EIK40601
EIK10202
EIK10202
EIK10202
EIK40602
HRK1020
HRK1020
HRK1020
HRK4060
H200SN
Std.
Std.
H600SN
H200SNC
H200SNC
H200SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC2
PKOGTA2
PKOGTC2
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H325AWK
H325DS
H325N
H325NAWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
H600SN
Std.
H600SN
H600SNC
H600SNC
H600SNC
Std.
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H325NDS
H325NR
H325R
H326
E4
E4
E4
E1
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
Std.
H600SN
H600SN
Std.
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H326AWK
H326DS
H326N
H326NAWK
E2
E2
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
Std.
H600SN
H600SN
H600SNC
H600SNC
H600SNC
Std.
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H326NDS
H326NR
H326R
H327
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
N/A
H600SN
Std.
H600SN
H800SNE4
Std.
H600SNC
H600SNC
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA7
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H327AWK
H327N
H327NAWK
H327NR
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H800SNE4
Std.
Std.
Std.
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA7
PKOGTA7
PKOGTA7
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H327R
H328
H328AWK
H328N
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H800SNE4
H1200SNE4
H1200SNE4
Std.
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA8
PKOGTA8
PKOGTA8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H328NAWK
H328NR
H328R
H361
E4
E4
E4
F5
EIK40601
EIK40601
EIK40601
EIK031
EIK40602
EIK40602
EIK40602
EIK032
N/A
N/A
N/A
RFK060
Std.
Std.
H1200SNE4
SN03
N/A
N/A
N/A
SN03C
PKOGTA8
PKOGTA8
PKOGTA8
GTK03
N/A
N/A
N/A
GTK03C
N/A
N/A
N/A
FPK03
N/A
N/A
N/A
N/A
H361-2A
H361-2AWK
H361A
H361AWA
F6
F6
F6
F7
EIK1
EIK1
EIK031
EIK1
EIK2
EIK2
EIK032
EIK2
RFK06
RFK06
RFK03H
RFK06
SN0610
SN0610
SN03
N/A
SN0610C
SN0610C.
SN03C
N/A
GTK0610
GTK0610
GTK03
N/A
GTK0610C
GTK0610C
GTK03C
Std.
Std.
Std.
Std.
Std.
N/A
N/A
N/A
ACP3034BC
H361AWC
H361AWK
H361DF
H361DS
F7
F6
F1
F6
EIK1
EIK031
9999TC10
EK3001
EIK2
EIK032
9999TC20
EIK032
RFK06
RFK03H
RKF06
HRK30H
N/A
SN03
H60SN
H60SN
N/A
H03C
H60SNC
H60SNC
N/A
GTK03
Std.
PK3GTA1
Std.
GTK03C
N/A
PKOGTC1
Std.
Std.
N/A
N/A
APJ3485
N/A
N/A
N/A
H361DSWC
H361DSWA
H361DX
H361N
F7
F7
F1
F5
EK3001
K3001
9999TC10
EIK031
EIK032
EIK032
EIK2
EIK2
HRK30H
HRK30H
RFK06
RFK03H
N/A
N/A
H60SN
Std.
N/A
N/A
H60SNC
SN03C
N/A
N/A
Std.
GTK03
Std.
Std.
N/A
GTK03C
Std.
Std.
Std.
FPK03
APJ3485
ACP3034BC
N/A
N/A
H361NRB
H361RB
H361WA
H361WC
F5
F5
F6
F6
EIK031
EIK031
EIK1
EIK1
EIK032
EIK0322
EIK2
EIK2
RFK03H
RFK03H
RFK06
RFK06
Std.
SN03
N/A
SN0610
SN03C
SN03C
N/A
SN0610C
GTK03
GTK03
Std.
Std.
GTK03C
GTK03C
N/A
N/A
FPK03
FPK03
FPK0610
FPK0610
N/A
N/A
ACP3034BC
APJ3485
H362
H362A
H362AWA
H362AWC
F5
F6
F5
F5
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
RFK06H
RFK06H
RFK06H
RFK06H
SN0610
SN0610
SN0610
SN0610
SN0610C
SN0610C
SN0610C
SN0610C
GTK0610
GTK0610
GTK0610
GTK0610
GTK0610C
GTK0610C
GTK0610C
GTK0610C
FPK0610
Std.
Std.
Std.
N/A
N/A
ACP6034BC
APJ6485
H362AWH
H362AWK
H362DF
H362DS
F5
F6
F1
F6
EIK1
EIK1
9999TC10
EK3061
EIK2
EIK2
9999TC20
EK3062
RFK06H
RFK06H
RFK06H
HRK60H
SN0610
SN0610
H60SN
H60SN
SN0610C
SN0610C
H60SNC
H60SNC
GTK0610
GTK0610
Std.
PK3GTA1
GTK0610C
GTK0610C
N/A
PKOGTC1
Std.
Std.
Std.
Std.
SD12781
N/A
N/A
N/A
H362DSWA
H362DSWK
H362DS
H362N
F7
F7
F1
F5
EK3061
EK3061
9999TC10
EIK1
EK3062
EK3062
9999TC20
EK032
HRK60H
HRK60H
RFK06H
RFK06H
N/A
N/A
H60SN
Std.
N/A
N/A
H60SNC
SN0610C
N/A
N/A
Std.
GTK0610
Std.
Std.
N/A
GTK0610C
Std.
Std.
Std.
FPK0610
ACP6034BC
APJ6485
N/A
N/A
Continued on next page
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
25
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 14: Accessories for Current Series Heavy Duty Safety Switches
Catalog
Number Series
Electrical
Interlock
(1 Contact)
Electrical
Interlocks
(2 Contacts)
Class R Kits
Solid
Neutral
(Al/Cu)
Solid
Neutral
(Cu Only)
Grounding
Kit
(Al)
Grounding
Kit
(Cu)
Fuse Puller Receptacle
Plugs
H362NRB
H362RB
H362WA
H362WC
F5
F5
F6
F6
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
RFK06H
RFK06H
RFK06H
RFK06H
Std.
SN0610
SN0610
SN0610
SN0610C
SN0610C
SN0610C
SN0610C
GTK0610
GTK0610
GTK0610
GTK0610
GTK0610C
GTK0610C
GTK0610C
GTK0610C
FPK0610
FPK0610
FPK0610
FPK0610
N/A
N/A
ACP6034BC
APJ6485
H362WH
H363
H363A
H363AWA
F5
F5
F6
F6
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
RFK06H
RFK10
RFK10
RFK10
SN0610
SN0610
SN0610
N/A
SN0610C
SN0610C
SN0610C
N/A
GTK0610
GTK0610
GTK0610
N/A
GTK0610C
GTK0610C
GTK0610C
Std.
FPK0610
FPK0610
Std.
Std.
SD12781
N/A
N/A
ACP1034CD
H363AWC
H363AWK
H363DF
H363DS
F6
F6
F1
F6
EIK1
EIK1
9999TC10
EK10201
EIK2
EIK2
9999TC20
EIK10202
RFK10
RFK10
RFK10
HRK1020
N/A
SN0610
SN0610
H100SN
N/A
SN0610C
SN0610C
H100SNC
N/A
GTK0610
Std.
PKOGTA2
Std.
GTK0610C
N/A
PKOGTC2
Std.
Std.
Std.
Std.
N/A
N/A
N/A
N/A
H363DSWA
H363DSWC
H363DX
H363N
F7
F7
F1
F5
EK10201
EK10201
9999TC10
EIK1
EIK10202
EIK10202
9999TC20
EIK2
HRK1020
HRK1020
RFK10
RFK10
N/A
N/A
SN0610
Std.
N/A
N/A
SN0610C
SN0610C
N/A
N/A
Std.
GTK0610
Std.
Std.
N/A
GTK0610C
Std.
Std.
Std.
FPK0610
ACP1034CD
APJ10487
N/A
N/A
H363NRB
H363RB
H363WA
H363WC
F5
F5
F6
F6
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
RFK10
RFK10
RFK10
RFK10
Std.
SN0610
N/A
N/A
SN0610C
SN0610C
N/A
N/A
GTK0610
GTK0610
N/A
N/A
GTK0610C
GTK0610C
N/A
N/A
FPK0610
FPK0610
FPK0610
FPK0610
N/A
N/A
ACP1034CD
APJ10487
H364
H364A
H364AWK
H364DF
F5
F6
F6
E1
EIK10201
EIK10201
EIK10201
9999R8
EIK10202
EIK10202
EIK10202
9999R9
HRK1020
HRK1020
HRK1020
HRK1020
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
PKOGTA2
PKOGTA2
PKOGTA2
Std.
PKOGTC2
PKOGTC2
PKOGTC2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H364DS
H364N
H364NA
H364NAWK
F6
F5
F6
F6
EK10201
EK10201
EK10201
EK10201
EK10202
EK10202
EK10202
EK10202
HRK1020
HRK1020
HRK1020
HRK1020
N/A
Std.
H200SN
H200SN
N/A
H200SNC
Std.
Std.
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC2
PKOGTC2
PKOGTC2
PKOGTC2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H364NDS
H364NRB
H364RB
H365
F6
F5
F5
E4
EK10201
EK10201
EK10201
EIK40601
EK10202
EK10202
EK10202
EIK40602
HRK1020
HRK1020
HRK1020
HRK4060
H200SN
Std.
N/A
H600SN
Std.
H200SNC
N/A
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC2
PKOGTC2
PKOGTC2
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H365AWK
H365DS
H365N
H365NAWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
H600SN
Std.
H600SN
H600SNC
H600SNC
H600SNC
Std.
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H365NDS
H365NR
H365R
H366
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
Std.
H600SN
H600SN
Std.
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H366AWK
H366DS
H366N
H366NAWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
HRK4060
H600SN
H600SN
Std.
H600SN
H600SNC
H600SNC
H600SNC
Std.
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H366NDS
H366NR
H366R
H367
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
HRK4060
HRK4060
HRK4060
N/A
H600SN
Std.
H600SN
H800SNE4
Std.
H600SNC
H600SNC
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA7
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H367AWK
H367N
H367NAWK
H367NR
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H800SNE4
Std.
Std.
Std.
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA7
PKOGTA7
PKOGTA7
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H367R
H368
H368AWK
H368N
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H800SNE4
H1200SNE4
H1200SNE4
Std.
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA8
PKOGTA8
PKOGTA8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
H368NAWK
H368NR
H368R
H461
E4
E4
E4
F5
EIK40601
EIK40601
EIK40601
EIK1
EIK40602
EIK40602
EIK40602
EIK2
N/A
N/A
N/A
RFK06
Std.
Std.
H1200SNE4
N/A
N/A
N/A
N/A
N/A
PKOGTA8
PKOGTA8
PKOGTA8
GTK0610
N/A
N/A
N/A
GTK0610C
N/A
N/A
N/A
FPK0610
N/A
N/A
N/A
N/A
H461AWK
H462
H462AWK
H462DS
F6
F5
F6
F6
EIK1
EIK1
EK3061
EIK1
EIK2
EIK2
EIK2
EK3062
RFK06
RFK06H
RFK06H
HRK30H
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GTK0610
GTK0610
GTK0610
PK3GTA1
GTK0610C
GTK0610C
GTK0610C
PKOGTC1
Std.
FPK0610
Std.
Std.
N/A
N/A
N/A
N/A
H463
H463AWK
H463DS
H464
F5
F6
F6
F5
EIK1
EIK1
EK10201
EK10201
EIK2
EIK2
EK10202
EK10202
RFK10
RFK10
HRK1020
HRK1020
N/A
SN0610
N/A
N/A
N/A
SN0610C
N/A
N/A
GTK0610
GTK0610
PKOGTA2
PKOGTA2
GTK0610C
GTK0610C
PKOGTC2
PKOGTC2
FPK0610
Std.
Std.
N/A
N/A
N/A
N/A
N/A
H464AWK
H464DS
H465
H465AWK
F6
F6
E4
E4
EK10201
EK10201
EIK40601
EIK40601
EK10202
EK10202
EIK40602
EIK40602
HRK1020
HRK1020
HRK4060
HRK4060
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC2
PKOGTC2
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Continued on next page
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
© 2009 Schneider Electric
All Rights Reserved
26
11/2009
Table 14: Accessories for Current Series Heavy Duty Safety Switches
Catalog
Number Series
Electrical
Interlock
(1 Contact)
Electrical
Interlocks
(2 Contacts)
Class R Kits
Solid
Neutral
(Al/Cu)
Solid
Neutral
(Cu Only)
Grounding
Kit
(Al)
Grounding
Kit
(Cu)
Fuse Puller Receptacle
Plugs
H466
H60XFA
H663AWK
H663DS
E4
F1
F5
F6
EIK40601
N/A
EIK1
EK10201
EIK40602
N/A
EIK2
EIK10202
HRK4060
N/A
RFK10
HRK1020
N/A
100SNA
N/A
N/A
N/A
N/A
N/A
N/A
PKOGTA2
Std.
GTK0610
PKOGTA2
PKOGTC3
N/A
GTK0610C
PKOGTC2
N/A
N/A
Std.
Std.
N/A
N/A
N/A
N/A
H664DS
H664AWK
HU265
HU265AWK
F6
F6
E4
E4
EK10201
EK10201
EIK40601
EIK40601
EIK10202
EIK10202
EIK40602
EIK40602
HRK1020
HRK1020
N/A
N/A
N/A
N/A
H600SN
H600SN
N/A
N/A
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU265DS
HU265R
HU266
HU266AWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H600SN
H600SN
H600SN
H600SN
H600SNC
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU266DS
HU266R
HU267
HU267AWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H600SN
H600SN
H600SN
H600SN
H600SNC
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU267R
HU268
HU268AWK
HU268R
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H800SNE4
H800SNE4
H1200SNE4
H1200SNE4
N/A
N/A
N/A
N/A
PKOGTA7
PKOGTA7
PKOGTA8
PKOGTA8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU361
HU361A
HU361AWA
HU361AWC
F5
F6
F7
F7
EIK031
EIK031
EIK1
EIK1
EIK032
EIK032
EIK2
EIK2
N/A
N/A
N/A
N/A
SN03
SN03
N/A
N/A
SN03C
SN03C
N/A
N/A
GTK03
GTK03
N/A
N/A
GTK03C
GTK03C
Std.
Std.
N/A
N/A
N/A
N/A
N/A
N/A
ACP3034BC
APJ3485
HU361AWK
HU361DF
HU361DS
HU361DSWA
F6
F1
F6
F7
EIK031
9999TC10
EK3001
EK3001
EIK032
9999TC20
EK3002
EK3002
N/A
N/A
N/A
N/A
SN03
H60SN
H60SN
N/A
SN03C
H60SNC
H60SNC
N/A
GTK03
Std.
PK3GTA1
N/A
GTK03C
N/A
PKOGTC1
Std.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
ACP3034BC
HU361DSWC
HU361DX
HU361RB
HU361WA
F7
F1
F5
F6
EK3061
9999TC10
EIK031
EIK1
EK3062
9999TC20
EIK032
EIK2
N/A
N/A
N/A
N/A
N/A
H60SN
SN03
N/A
N/A
H60SNC
SN03C
N/A
N/A
Std.
GTK03
Std.
Std.
N/A
GTK03C
N/A
N/A
N/A
N/A
N/A
APJ3485
N/A
N/A
ACP3034BC
HU361WC
HU362
HU362A
HU362AWA
F6
F5
F6
F6
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
N/A
N/A
N/A
N/A
SN0610
SN0610
SN0610
SN0610
SN0610C
SN0610C
SN0610C
SN0610C
Std.
GTK0610
GTK0610
GTK0610
N/A
GTK0610C
GTK0610C
GTK0610C
N/A
N/A
N/A
N/A
APJ3485
N/A
N/A
ACP6034BC
HU362AWC
HU362AWH
HU362AWK
HU362DF
F7
F6
F7
F1
EIK1
EIK1
EIK1
9999TC10
EIK2
EIK2
EIK2
9999TC20
N/A
N/A
N/A
N/A
SN0610
SN0610
SN0610
H60SN
SN0610C
SN0610C
SN0610C
H60SNC
GTK0610
GTK0610
GTK0610
Std.
GTK0610C
GTK0610C
GTK0610C
N/A
N/A
N/A
N/A
N/A
APJ6485
SD12781
N/A
N/A
HU362DS
HU362DSWA
HU362DSWC
HU362DX
F6
F7
F7
F1
EK3061
EK3061
EK3061
9999TC10
EK3062
EK3062
EK3062
9999TC20
N/A
N/A
N/A
N/A
H60SN
N/A
N/A
H60SN
H60SNC
N/A
N/A
H60SNC
PK3GTA1
N/A
N/A
Std.
PKOGTC1
Std.
Std.
N/A
N/A
N/A
N/A
N/A
N/A
ACP6034BC
APJ6485
N/A
HU362RB
HU362WA
HU362WC
HU362WH
F5
F6
F6
F5
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
N/A
N/A
N/A
N/A
SN0610
N/A
SN0610
N/A
SN0610C
N/A
SN0610C
N/A
GTK0610
Std.
Std.
Std.
GTK0610C
N/A
Std.
Std.
N/A
N/A
N/A
N/A
N/A
ACP6034BC
APJ6485
SD12781
HU363
HU363A
HU363AWA
HU363AWC
F5
F6
E4
E4
EIK1
EIK1
EIK1
EIK1
EIK2
EIK2
EIK2
EIK2
N/A
N/A
N/A
N/A
SN0610
SN0610
N/A
N/A
SN0610C
SN0610C
N/A
N/A
GTK0610
GTK0610
N/A
N/A
GTK0610C
GTK0610C
Std.
Std.
N/A
N/A
N/A
N/A
N/A
N/A
ACP1034CD
APJ10487
HU363AWK
HU363DF
HU363DS
HU363DSWA
E4
E4
F6
F7
EIK1
9999TC10
EIK10201
EIK10201
EIK2
9999TC20
EIK10202
EIK10202
N/A
N/A
N/A
N/A
SN0610
SN0610
H100SN
N/A
SN0610C
SN0610C
H100SNC
N/A
GTK0610
N/A
PKOGTA2
N/A
GTK0610C
N/A
PKOGTC2
Std.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
ACP1034CD
HU363DSWC
HU363DX
HU363RB
HU363WA
F7
F1
F5
F5
EIK10201
9999TC10
EIK1
EIK1
EIK10202
9999TC20
EIK2
EIK2
N/A
N/A
N/A
N/A
N/A
SN0610
SN0610
N/A
N/A
SN0610C
SN0610C
N/A
N/A
Std.
GTK0610
Std.
Std.
N/A
GTK0610C
N/A
N/A
N/A
N/A
N/A
APJ10487
N/A
N/A
ACP1034CD
HU363WC
HU364
HU364A
HU364AWK
F5
F5
F6
F6
EIK1
EK10201
EK10201
EK10201
EIK2
EK10202
EK10202
EK10202
N/A
N/A
N/A
N/A
N/A
H200SN
H200SN
H200SN
N/A
H200SNC
H200SNC
H200SNC
Std.
PKOGTA2
PKOGTA2
PKOGTA2
N/A
PKOGTC2
PKOGTC2
PKOGTC2
N/A
N/A
N/A
N/A
APJ10487
N/A
N/A
N/A
HU364DF
HU364DS
HU364RB
HU365
E1
F6
F5
E4
9999R8
EK10201
EK10201
EIK40601
9999R9
EK10202
EK10202
EIK40602
N/A
N/A
N/A
N/A
N/A
H200SN
H200SN
H600SN
N/A
H200SNC
H200SNC
H600SNC
Std.
PKOGTA2
PKOGTA2
PKOGTA2
N/A
PKOGTC2
PKOGTC2
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Continued on next page
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
27
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 14: Accessories for Current Series Heavy Duty Safety Switches
Catalog
Number Series
Electrical
Interlock
(1 Contact)
Electrical
Interlocks
(2 Contacts)
Class R Kits
Solid
Neutral
(Al/Cu)
Solid
Neutral
(Cu Only)
Grounding
Kit
(Al)
Grounding
Kit
(Cu)
Fuse Puller Receptacle
Plugs
HU365AWK
HU365DS
HU365R
HU366
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H600SN
H600SN
H600SN
H600SN
H600SNC
H600SNC
H600SNC
H600SNC
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU366AWK
HU366DS
HU366R
HU367
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H600SN
H600SN
H600SN
H800SNE4
H600SNC
H600SNC
H600SNC
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA7
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU367AWK
HU367R
HU368
HU368AWK
E4
E4
E4
E4
EIK40601
EIK40601
EIK40601
EIK40601
EIK40602
EIK40602
EIK40602
EIK40602
N/A
N/A
N/A
N/A
H800SNE4
H800SNE4
H1200SNE4
H1200SNE4
H600SNC
H600SNC
H600SNC
H600SNC
PKOGTA7
PKOGTA7
PKOGTA8
PKOGTA8
PKOGTC3
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU368R
HU461
HU461AWK
HU461DS
E4
F5
E1
F6
EIK40601
EIK1
EK3061
EK3061
EIK40602
EIK2
EK3062
EK3062
N/A
N/A
N/A
N/A
H1200SNE4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
PKOGTA8
GTK0610
PK3GTA1
PK3GTA1
N/A
GTK0610C
PKOGTC1
PKOGTC1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU462
HU462AWK
HU462DS
HU463
F5
F6
F6
F5
EIK1
EIK1
EK3061
EIK1
EIK2
EIK2
EK3062
EIK2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GTK0610
GTK0610
PK3GTA1
GTK0610
GTK0610C
GTK0610C
PKOGTC1
GTK0610C
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU463AWK
HU463DS
HU464
HU464AWK
F6
F6
F5
F6
EIK1
EK10201
EK10201
EK10201
EIK2
EK10202
EK10202
EK10202
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GTK0610
PKOGTA2
PKOGTA2
PKOGTA2
GTK0610C
PKOGTC2
PKOGTC2
PKOGTC2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU464DS
HU465
HU465AWK
HU466
F6
E4
E4
E4
EK10201
EIK1
EIK40601
EIK40601
EK10202
EIK2
EIK40602
EIK40602
N/A
N/A
N/A
N/A
N/A
H600SN
N/A
N/A
N/A
N/A
N/A
N/A
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTA2
PKOGTC2
PKOGTC3
PKOGTC3
PKOGTC3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU661AWK
HU661DS
HU662AWK
HU662DS
F6
F6
F6
F6
EIK1
EK3001
EIK1
EK3061
EIK2
EK3002
EIK2
EK3062
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GTK0610
PK3GTA1
GTK0610
PK3GTA1
GTK0610C
PKOGTC1
GTK0610C
PKOGTC1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
HU663AWK
HU663DS
HU664DS
HU664RWK
F6
F6
F6
F6
EIK1
EK10201
EK10201
EK10201
EIK2
EK10202
EK10202
EK10202
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
GTK0610
PKOGTA2
PKOGTA2
PKOGTA2
GTK0610C
PKOGTC2
PKOGTC2
PKOGTC2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
28
11/2009
General Information
UL Listed Maximum Short Circuit Current RatingsAC Only
NOTE: Consult the wiring diagram of the switch to verify the UL Listed short
circuit current rating.
Table 15: Fusible Short Circuit Current Ratings
Heavy Duty Safety Switch
Type UL Listed Fuse Class UL Listed Short Circuit
Current Ratings
Fusible H, K 10 kA
R, J, L 200 kA 1
1On 600 V 200 A switches, 100,000 A max. on corner grounded delta when protected by Class J or R fuses.
Table 16: Non-Fusible Safety Switches
Heavy Duty
Safety Switch
Type
Switch Rating
(A) 1
1Applies to NEMA Types 1, 3R, 4X stainless, 12 switches.
Fuse or Circuit
Breaker Type2
2Ampere rating of fuse or circuit breaker not to exceed switch ampere rating.
3-Phase
240 Vac 480 Vac 600 Vac
Non-Fusible
Switches
All
Any brand circuit breaker Up to 10 kA
H, K
R,T,J.L 200 kA 200 kA 200 kA
30–100 H 3
3All H and J circuit breakers are acceptable, but will only support the noted Short Circuit Current Rating.
65 kA 35 kA 25 kA
30–100 FA 14 kA 14 kA 14 kA
30–100 FH 18 kA 18 kA 18 kA
200 H, J 365 kA 35 kA 25 kA
200 KA
22 kA 22 kA 22 kA400 LA
600 MA
200 KH
25 kA 25 kA 25 kA400 LH
600 MH
Table 17: Terminal Lug Data (NEMA Types 1, 3R, 4, 4X, 5, 7, 9, 12) 1
130–100 A switches suitable for 60°C or 75°C conductors. 200–1200 A switches suitable for 75oC conductors.
Rating
(A)
Conductors
Per Phase
and Neutral
Wire Range
Wire Bending
Space Per NEC
Table 312.6
AWG/kcmil
Lug Wire Range
AWG/kcmil
Optional Versa-Crimp®
Compression Lug
Field-Installed 2
2For NEMA Types 1 and 3R only.
30 3
3HU461AWK— 14–6 AWG (Cu).
1 12–6 (Al) or
14–6 (Cu) 12–2 (Al)
or
14–2 (Cu)
2
14–10 (Cu) solid
or 14–10 (Cu)
stranded
60 4
4H60XFA— 14–6 AWG (Cu).
1 14–3 (Al) or
14–3 (Cu) 12–2 (Al) or 14–2 (Cu)
100 1 12–1/0 (Al) or
14–1/0 (Cu) 12–1/0 (Al) or 14–1/0 (Cu) VCEL02114S1
200 5
5H225XKA— 4 AWG–300 kcmil (Cu).
1 6–250 (Al/Cu) 6–300 (Al/Cu) VCEL030516H1
400
VCEL07512H1
1 1/0–750 (Al/Cu) 6
6Maximum wire range is (1) 600 kcmil or (2) 300 kcmil Al/Cu on NEMA Type 4X Stainless and NEMA Type 12.
1/0–750 (Al/Cu) or
or or and VCEL030516H1 7
7Order two PK516KN mounting kits when installing VCEL030516H1 lugs. Only one kit is required on two-pole
switches.
2 1/0–300 (Al/Cu) 1/0–300 (Al/Cu) and
VCEL05012H1
600 2 3/0–500 (Al/Cu) 3/0–500 (Al/Cu) VCEL05012H1
800 3 3/0–750 (Al/Cu) 3/0–750 (Al/Cu) H8LKE2 8
8See Digest 175 page 13, 800 and 1200 A compression lug kits for additional information.
1200 4 3/0–750 (Al/Cu) 3/0–750 (Al/Cu) H12LKE2 8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
29
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 18: 30 A Heavy Duty Rating
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
3Ø 1Ø 125 250 600 2Ø 2Ø
H221DS
H221A
H221AWK
F6
F6
F6
1/2
2
1-1/2
1-1/21
1-1/21
32
32
3
3
3
7-1/22
7-1/22
3
3
5
5
5
H221N
H221NRB
F5
F5
1/2
1/2
2
2
1-1/21
1-1/2132
323
327-1/22
7-1/22
3
3
53
53
H321DS
H321A
H321AWK
F6
F6
F6
1/2
1/2
2
2
1-1/21
1-1/21
1-1/21
32
32
32
32
32
7-1/22
7-1/22
7-1/22
3
3
51
53
53
H321N
H321NRB
F5
F5
1/2
1/2
1-1/21
1-1/2132
3232
327-1/22
7-1/22
3
3
53
53
H361
H361RB
H361DS
H361A
H361AWK
F5
F5
F6
F6
F6
31
31
31
31
52
52
5
52
52
7-1/21
7-1/21
7-1/21
7-1/21
152
152
15
152
152
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
20
20
20
20
20
53
53
53
53
15
15
15
15
15
H3612A
H3612AWK
F6
F6
31
3152
527-1/21
7-1/21152
152
7-1/2
7-1/2
20
20
15
15
H361N
H361NRB
F5
F5
31
317-1/22
7-1/2251
51152
152
7-1/2
7-1/2
20
20
51
51151
151
H461
H461DS
H461AWK
F5
F6
F6
3
3
7-1/2
7-1/2
5
7-1/2
5
15
20
15
7-1/2
10
7-1/2
20
25
20
33
33
53
53
15
15
3
3
10
10
7-1/2
7-1/2
20
20
10
10
25
25
HU361
HU361RB
HU361DS
HU361A
HU361AWK
F5
F5
F6
F6
F6
2
2
2
2
2
51
51
51
51
51
101
101
101
101
101
7-1/21
7-1/21
7-1/21
7-1/21
7-1/21
202
202
20
202
202
101
101
101
101
101
30
30
30
30
30
3
3
3
3
3
5
5
5
5
5
15
15
15
15
15
HU461
HU461DS
HU461AWK
F5
F6
E1
10
10
10
20
20
20
30
30
30
3
2
3
10
5
10
15
10
15
10
10
10
20
20
20
25
25
25
1Use both outer switching poles.
2For corner grounded only, install neutral and use switching poles for ungrounded conductors.
3Standard hp rating.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
30
11/2009
Table 19: 60 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 3Ø 1Ø 3Ø 125 250 600 2Ø 2Ø
H222DS
H222A
H222AWK
F6
F6
F6
1-1/2
1-1/2
3
3
3
31
31
7-1/22
7-1/22
10
101
101
152
152
53
53
10
103
103
H222N
H222NRB
F5
F5
1-1/2
1-1/2
3
3
31
317-1/22
7-1/22101
101152
152
53
53103
103
H322DS
H322A
H322AWK
F6
F6
F6
1-1/2
1-1/2
3
3
31
31
7-1/22
7-1/22
7-1/22
101
101
152
152
152
53
53
10
103
103
H322N
H322NRB
F5
F5
1-1/2
1-1/2
3
3
31
317-1/22
7-1/22101
101152
152
53
53103
103
H362
H362RB
H362DS
H362A
H362AWK
F5
F5
F6
F6
F6
51
51
51
51
152
152
152
152
201
201
201
201
302
302
30
302
302
15
15
15
15
15
50
50
50
50
50
30
30
30
30
30
H362N
H362NRB
F5
F5
51
51152
152201
201302
302
15
15
50
50
30
30
H462
H462DS
H462AWK
F5
F6
F6
7-1/2
7-1/2
15
15
15
15
15
30
40
30
15
20
15
50
50
50
5
5
10
10
30
30
7-1/2
7-1/2
20
20
15
15
40
40
20
20
50
50
HU362
HU362RB
HU362DS
HU362A
HU362AWK
F5
F5
F6
F6
F6
5
5
5
5
5
101
101
101
101
101
204
204
20
204
204
251
251
204
251
251
502 5
502 5
506
502 5
502 5
301
301
251
301
301
606
606
606
606
606
5
5
5
5
5
10
10
10
10
10
30
30
30
30
30
HU462
HU462DS
HU462AWK
F5
F6
F6
20
20
20
50
50
50
60
60
60
5
5
5
10
10
10
30
30
30
20
20
20
40
40
40
50
50
50
HU662DS
HU662AWK
F6
F6
20
20
50
50
60
60
1Use both outer switching poles.
2For corner grounded delta only, install neutral and use switching poles for ungrounded conductors.
3Standard hp rating.
415 hp maximum on a corner grounded delta system.
530 hp maximum on a corner grounded delta system.
6Use 75°C N.O. 4 Cu or N.O. 2 Al conductors.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
31
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 20: 100 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 125 250 600 2Ø
H223DS
H223AWK
H223A
F6
F6
F6
7-1/2
7-1/21
7-1/21
152
152
15
151
151
302
302
20
203
203
H223N
H223NRB
F5
F5
7-1/21
7-1/21152
152151
151302
302
203
203
H323DS
H323A
H323AWK
F6
F6
F6
7-1/21
7-1/21
15
152
152
151
151
30
302
302
20
203
203
H323N
H323NRB
F5
F5
7-1/21
7-1/21152
152151
151302
302
203
203
H363
H363RB
H363DS
H363A
H363AWK
F5
F5
F6
F6
F6
101
101
101
101
252
252
25
252
252
301
301
301
301
602
602
60
602
602
30
30
30
30
30
75
75
75
75
75
50
50
50
50
30
30
30
30
30
H363N
H363NRB
F5
F5
101
101252
252301
301602
602
30
30
75
75
50
50
30
30
H463
H463DS
H463AWK
F5
F6
F6
15
15
30
30
25
25
60
60
30
30
75
75
203
203
30
30
7-1/2
7-1/2
20
20
15
15
40
40
20
20
50
50
H663DS
H663AWK
F6
F6
15
30
25
60
30
75
HU363
HU363RB
HU363DS
HU363A
HU363AWK
F5
F5
F6
F6
F6
7-1/2
7-1/2
101
7-1/2
7-1/2
201
201
151
201
201
402 6
402 6
404
402 6
402 6
401
401
301
401
401
755 6
755 6
75
755 6
755 6
401
401
401
401
401
756
756
754
756
756
7-1/2
7-1/2
10
7-1/2
7-1/2
20
20
20
20
20
50
50
50
50
HU463
HU463DS
HU463AWK
F5
F6
F6
40
40
40
75
75
75
75
75
75
20
20
20
30
30
30
30
30
30
50
50
50
50
50
50
HU663DS
HU663AWK
F6
F6
40
40
75
75
75
75
1Use both outer switching poles.
2For corner grounded delta only, install neutral and use switching poles for ungrounded conductors.
3Standard hp rating.
4Use 75°C No. 1 copper conductor only.
560 hp maximum on corner grounded delta.
6Use 75°C N.O. 4 Cu or N.O. 2 Al conductors.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
32
11/2009
Table 21: 200 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 3Ø 1Ø 3Ø 3Ø 1Ø 125 250 600
H224DS
H224A
H224AWK
F6
F6
F6
15
15
15
40
40
40
H224N
H224NRB
F5
F5
151 2
25
25
151 2 60
60
40
40
H324DS
H324A
H324AWK
F6
F6
F6
25
25
25
60
60
60
40
40
40
H324N
H324NRB
F5
F5
25
25
60
60
40
40
H364
H364RB
H364DS
H364A
H364AWK
F6
F5
F6
F6
F6
50
50
50
50
50
125
125
125
125
125
60
60
60
60
60
150
150
150
150
150
50
50
50
50
50
H364N
H364NRB
F6
F5
50
50
125
125
60
60
150
150
50
50
H464
H464DS
H464AWK
F5
F6
F6
50
50
50
50
50
50
50
50
50
50
50
50
H664DS
H664AWK
F6
F6
HU364
HU364RB
HU364DS
HU364A
HU364AWK
F5
F5
F6
F6
F6
60
60
60
60
125
125
125
125
125
150
150
150
150
150
40
40
40
40
40
50
50
50
50
50
HU464
HU464DS
HU463AWK
F5
F6
F6
50
50
50
50
50
50
50
50
50
HU664DS
HU664AWK
F6
F6
75
75
150
150
150
150
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
33
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 22: 400 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 1Ø 3Ø 1Ø 3Ø 125 250 600 2Ø
H225
H225R
H225DS
H225AWK
E4
E4
E4
E4
50
50
50
50
H225N
H225NR
H225NDS
H225NAWK
E4
E4
E4
E4
501
501
501
501
1251
1251
1251
1251
H325
H325R
H325DS
H325AWK
E4
E4
E4
E4
50
50
50
50
125
125
125
125
50
50
50
50
H325N
H325NR
H325NDS
H325NAWK
E4
E4
E4
E4
50
50
50
50
125
125
125
125
50
50
50
50
H265
H265R
H265DS
H265AWK
E4
E4
E4
E4
1001
1001
1001
1001
2501
2501
2501
2501
50
50
50
H365
H365R
H365DS
H365AWK
E4
E4
E4
E4
100
100
100
100
250
250
250
250
125
125
125
125
350
350
350
350
50
50
50
50
H365N
H365NR
H365NDS
H365NAWK
E4
E4
E4
E4
100
100
250
250
125
125
350
350
H4652
H465AWK2E4
E4
HU265
HU265R
HU265DS
HU265AWK
E4
E4
E4
E4
50
50
50
50
HU365
HU365R
HU365DS
HU365AWK
E4
E4
E4
E4
125
125
250
250
350
350
50
50
HU4652
HU465AWK2E4
E4
1For corner grounded only, install neutral and use switching poles for ungrounded conductors.
2Not suitable for use as service equipment.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
34
11/2009
Table 23: 600 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 3Ø 1Ø 3Ø 3Ø 1Ø 125 250 600
H226
H226R
H226DS
H226AWK
E4
E4
E4
E4
751
751
751
751
2001
2001
2001
2001
H226N
H226NR
H226NDS
H226NAWK
E4
E4
E4
E4
751
751
751
751
2001
2001
2001
2001
H326
H326R
H326DS
H326AWK
E4
E4
E4
E4
75
75
75
75
200
200
200
200
H326N
H326NR
H326NDS
H326NAWK
E4
E4
E4
E4
75
75
75
75
200
200
200
200
H266
H266R
H266DS
H266AWK
E4
E4
E4
E4
1501
1501
1501
1501
4001
4001
4001
4001
H366
H366R
H366DS
H366AWK
E4
E4
E4
E4
150
150
150
150
400
400
400
400
200
200
200
200
500
500
500
500
H366N
H366NR
H366NDS
H366NAWK
E4
E4
E4
E4
150
150
150
150
400
400
400
400
200
200
200
200
500
500
500
500
H4662E4 — — ——————— ———
HU266
HU266R
HU266DS
HU266AWK
E4
E4
E4
E4
HU366
HU366R
HU366DS
HU366AWK
E4
E4
E4
E4
200
200
200
200
400
400
400
400
500
500
500
500
HU4662E4 ——— ———— —————— — ———
1For corner grounded only, install neutral and use switching poles for ungrounded conductors.
2Not suitable for use as service equipment.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
35
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 24: 800 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 1Ø 3Ø 1Ø 3Ø 125 250 600 2Ø
H227
H227R
H226AWK
E4
E4
E4
50
50
50
H227N
H227NR
H227NAWK
E4
E4
E4
50
50
50
H327
H327R
H327AWK
E4
E4
E4
100
100
100
250
250
250
50
50
50
H327N
H327NR
H327NAWK
E4
E4
E4
100
100
100
250
250
250
50
50
50
H267N
H267R
H267AWK
E4
E4
E4
50
50
50
H367
H367R
H367AWK
E4
E4
E4
100
100
100
250
250
250
200
200
200
500
500
500
250
250
250
500
500
500
50
50
50
H367N
H367NR
H367NAWK
E4
E4
E4
100
100
100
250
250
250
200
200
200
500
500
500
250
250
250
500
500
500
50
50
50
HU267
HU267R
HU267AWK
E4
E4
E4
100
100
100
100
100
100
50
50
50
HU367
HU367R
HU367AWK
E4
E4
E4
100
100
100
100
100
100
500
500
500
500
500
500
50
50
50
Table 25: 1200 A Heavy Duty Ratings
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc 240 Vac 480 Vac 600 Vac
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings Std. Max. Std. Max. Std. Max.
1Ø 1Ø 1Ø 3Ø 1Ø 3Ø 125 250 600 2Ø
H228
H228R
H228AWK
E4
E4
E4
50
50
50
H228N
H228NR
H228NAWK
E4
E4
E4
50
50
50
H328
H328R
H328AWK
E4
E4
E4
100
100
100
250
250
250
50
50
50
H328N
H328NR
H328NAWK
E4
E4
E4
100
100
100
250
250
250
50
50
50
H268N
H268R
H268AWK
E4
E4
E4
50
50
50
H368
H368R
H368AWK
E4
E4
E4
100
100
100
250
250
250
200
200
200
500
500
500
250
250
250
500
500
500
50
50
50
H368N
H368NR
H368NAWK
E4
E4
E4
100
100
100
250
250
250
200
200
200
500
500
500
250
250
250
500
500
500
50
50
50
HU268
HU268R
HU268AWK
E4
E4
E4
100
100
100
100
100
100
50
50
50
HU368
HU368R
HU368AWK
E4
E4
E4
100
100
100
100
100
100
500
500
500
500
500
500
50
50
50
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
36
11/2009
Table 26: Specialty Switches
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings
1Ø 1Ø 1Ø 3Ø 125 250 600
Fiberglass Reinforced Polyester Enclosures—NEMA Type 4X
H361DF
H362DF
H363DF
H364DF
F1
F1
F1
E1
1-1/21
31
7-1/21
32
7-1/22
152
25
31
101
151
7-1/22
152
302
60
31
51
101
52
152
252
50
7-1/21
201
301
152
302
602
125
7-1/2
15
30
60
15
50
75
150
5
10
20
40
15
30
50
50
HU361DF
HU362DF
HU363DF
HU364DF
F1
F1
E1
E1
11
51
7-1/2
201
51
101
102
202 3
30
60
101
251
401
202
302 3
752 4
125
30
60
75
150
3
5
7-1/2
10
10
20
40
15
30
50
50
Krydon Enclosures
H361DX
H362DX
H363DX
F1
F1
F1
1-1/21
31
7-1/21
32
7-1/22
152
31
101
151
7-1/22
152
302
31
51
101
52
152
252
7-1/21
201
301
152
302
602
7-1/2
15
30
20
50
75
5 5
105
205
156
307
508
HU361DX
HU362DX
HU363DX
F1
F1
F1
3
5
7-1/2
51
101
201
102
202 3
302
101
251
401
202
502 9
752 4
30
60
75
3
5
7-1/2
10
10
20
15
30
50
NEMA Types 7 and 9 Enclosures
H60XFA
H60XFA1212
E1
E1
15
15
30
30
50
50
H100XFA
H100XFA1212
E1
E1
30
30
60
60
75
75
H225XKA C2 60 — 125 150 — —
1Use outer switching poles.
2For corner grounded only, install neutral and use switching poles for ungrounded conductors.
315 hp rating on corner grounded delta system.
460 hp rating on corner grounded delta system.
5Standard hp rating.
6Standard hp rating: 10 hp.
7Standard hp rating: 25 hp.
8Standard hp rating: 40 hp.
930 hp rating on corner grounded delta system.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
37
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 27: Receptacle Switches
Catalog
Number Series
120 Vac 240 Vac 480 Vac 600 Vac Vdc
Std. Max. Std. Max. Std. Max. Std. Max. Max. hp Ratings
1Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 125 250 600
H361WA
H361DSWA
H361AWA
F6
F7
F5
5
5
5
15
15
15
7-1/2
7-1/2
7-1/2
20
20
20
51
51
51
HU361WA
HU361DSWA
HU361AWA
F6
F7
F7
20
20
20
30
30
30
51
51
51
H361WC
H361DSWC
H361AWC
F6
F7
F7
31
31
5
5
7-1/21
7-1/21
15
15
7-1/2
7-1/2
20
20
31 2
31 2
51
51
HU361WC
HU361DSWC
HU361AWC
F6
F7
F7
2
2
2
51
51
51
10
10
10
101
7-1/21
101
20
20
20
151
101
151
30
30
30
31
31
31
101
51
101
H362WA
H362DSWA
H362AWA
F6
F7
F7
15
15
15
30
30
30
15
15
15
50
50
50
101 3
101 3
101 3
HU362WA
HU362DSWA
HU362AWA
F6
F7
F7
50
50
50
60
60
60
101
101
101
H362WC
H362DSWC
H362AWC
F6
F7
F7
1-1/2
3
31
31
7-1/2
7-1/2
101
101
15
15
51
51
51
15
15
15
201
201
201
30
30
30
101
15
15
15
251
50
50
50
51 3
51 3
101 3
101
101 3
HU362WC
HU362DSWC
HU362AWC
F6
F7
F7
5
5
5
101
101
101
20
20
204 5
251
201
25
50
50
505 6
301
251
301
60
60
60
51
51
101
101
101
H362WH
H362AWH
F5
F6
51
5115
15
201
20130
30
15
15
50
50
HU362WH
HU362AWH
F5
F6
5
5
101
10120
20
H363WA
H363DSWA
H363AWA
F6
F7
F7
25
25
25
60
60
60
30
30
30
75
75
75
201 3
201 3
201 3
HU363WA
HU363DSWA
HU363AWA
F6
F7
F7
75
75
75
75
75
75
201
201
201
H363WC
H363DSWC
H363AWC
F6
F7
F7
101
101
25
25
25
301
301
60
60
30
30
30
30
75
75
75
201 3
201 3
201 3
HU363WC
HU363DSWC
HU363AWC
F6
F7
F7
10
7-1/2
151
201
403 7
30
301
401
75
75
75
401
401
75
753 7
75
101
7-1/21
201
201
201
1Use both outer switching poles.
2Two standard hp rating.
3Standard hp rating.
4Fifteen hp maximum on a corner grounded delta system.
5Not applicable for corner grounded delta.
6Thirty hp maximum on a corner grounded delta system.
7Use 75°C N.O. 4 Cu or N.O. 2 Al conductors.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
38
11/2009
W
W
W/H
H
H
W/H D
D
Typical NEMA Type 1
Typical NEMA Type 3R
Table 28: Dimensions
Catalog
Number Series
Approximate Dimensions
H W W/H D
in. mm in. mm in. mm in. mm
H221N
H221NRB
H222N
H222NRB
F5
14.60
14.88
14.60
14.88
371
378
371
378
6.50
6.63
6.50
6.63
165
168
165
168
7.55
7.55
7.55
7.55
192
192
192
192
4.88
4.88
4.88
4.88
124
124
124
124
H223N
H223NRB
H224N
H224NRB
F5
21.25
21.25
29.00
29.25
540
540
737
743
8.50
8.50
17.13
17.25
216
216
435
438
10.50
10.50
18.50
18.63
267
267
470
473
6.38
6.38
8.25
8.50
162
162
210
216
H225, N
H225NR, R
H226, N
H226NR, R
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
27.63
27.88
27.63
27.88
702
708
702
708
27.63
27.88
27.63
27.88
702
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
H227, N
H227NR, R
H228, N
H228NR, R
E4
69.13
69.13
69.13
69.13
1756
1756
1756
1756
36.62
36.62
36.62
36.62
930
930
930
930
36.62
36.62
36.62
36.62
930
930
930
930
17.75
17.75
17.75
17.75
451
451
451
451
H265
H265R
H266
H266R
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
27.63
27.88
27.63
27.88
702
708
702
708
27.63
27.88
27.63
27.88
702
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
H267
H267R
H268
H268R
E4
69.13
69.13
69.13
69.13
1756
1756
1756
1756
36.62
36.62
36.62
36.62
930
930
930
930
36.62
36.62
36.62
36.62
930
930
930
930
17.75
17.75
17.75
17.75
451
451
451
451
H321N
H321NRB
H322N
H322NRB
F5
14.60
14.88
14.60
14.88
371
378
371
378
6.50
6.63
6.50
6.63
165
168
165
168
7.55
7.55
7.55
7.55
192
192
192
192
4.88
4.88
4.88
4.88
124
124
124
124
H323N
H323NRB
H324N
H324NRB
F5
21.25
21.25
29.00
29.25
540
540
737
743
8.50
8.50
17.13
17.25
216
216
435
438
10.50
10.50
18.50
18.63
267
267
470
473
6.38
6.38
8.25
8.50
162
162
210
216
H325, N
H325R, NR
H326, N
H326R, NR
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
27.63
27.88
27.63
27.88
702
708
702
708
27.63
27.88
27.63
27.88
702
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
H327, N
H327R, NR
H328, N
H328R, NR
E4
69.13
69.13
69.13
69.13
1756
1756
1756
1756
36.62
36.62
36.62
36.62
930
930
930
930
36.62
36.62
36.62
36.62
930
930
930
930
17.75
17.75
17.75
17.75
451
451
451
451
H361, N
H361-2
H361NRB, RB
F5
14.60
17.50
14.88
371
445
378
6.50
9.00
6.63
165
229
168
7.55
10.50
7.55
192
267
192
4.88
6.38
4.88
124
162
124
H361WA
H361WC F6 18.19
18.19
462
462
9.00
9.00
229
229
10.50
10.50
267
267
6.81
6.81
173
173
H362, N
H362NRB, RB F5 17.50
17.50
445
445
9.00
9.00
229
229
10.50
10.50
267
267
6.38
6.38
162
162
H362WA
H362WC F6 18.19
16.75
462
425
9.00
9.00
229
229
10.50
10.50
267
267
6.81
7.00
173
178
H362WH
H363, N
H363NRB, RB
F5
18.19
21.25
21.25
462
540
540
9.00
8.50
8.50
229
216
216
10.50
10.50
10.50
267
267
6.81
6.38
6.38
173
162
162
H363WA
H363WC F6 21.85
21.85
462
555
9.00
9.00
229
229
10.50
10.50
267
267
6.81
6.81
173
173
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
39
11/2009
© 2009 Schneider Electric
All Rights Reserved
W
W
W/H
H
H
W/H D
D
Typical NEMA Type 1
Typical NEMA Type 3R
Table 29: Dimensions
Catalog
Number Series
Approximate Dimensions
H W W/H D
in. mm in. mm in. mm in. mm
H364
H364N
H364NRB
H364RB
F5
29.00
29.00
29.25
29.25
737
737
743
743
17.13
17.13
17.25
17.25
435
435
438
438
18.50
18.50
18.63
18.63
470
470
473
473
8.25
8.25
8.50
8.50
210
210
216
216
H365, N
H365R, NR
H366, N
H366NR, R
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
27.63
27.88
27.63
27.88
702
708
702
708
27.63
27.88
27.63
27.88
702
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
H367, N
H367NR, R
H368, N
H368NR, R
E4
69.13
69.13
69.13
69.13
1756
1756
1756
1756
36.62
36.62
36.62
36.62
930
930
930
930
36.62
36.62
36.62
36.62
930
930
930
930
17.75
17.75
17.75
17.75
451
451
451
451
H461
H462
H463
H464
F5
20.50
20.50
20.50
29.00
521
521
521
737
14.75
14.75
14.75
23.25
375
375
375
591
16.13
16.13
16.13
24.88
410
410
410
632
17.75
17.75
17.75
8.75
451
451
451
222
H465
H466
HU265
HU265R
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
33.88
27.88
27.63
27.88
861
708
702
708
33.88
27.88
27.63
27.88
861
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
HU266
HU266R
HU267
HU267R
E4
50.25
50.31
69.13
69.13
1276
1278
1756
1756
27.63
27.88
36.62
36.62
702
708
930
930
27.63
27.88
36.62
36.62
702
708
930
930
10.13
10.13
17.75
17.75
257
257
451
451
HU268
HU268R
HU361
H361RB
E4 69.13
69.13
1756
1756
36.62
36.62
930
930
36.62
36.62
930
930
17.75
17.75
451
451
F5 14.60
14.88
371
378
6.50
6.63
165
168
7.55
7.55
192
192
4.88
4.88
124
124
HU362
HU362RB
HU362WH
HU363
F5
17.75
21.25
21.25
21.25
445
540
540
540
9.00
8.50
8.50
8.50
229
216
216
216
10.50
10.50
10.50
10.50
267
267
267
267
6.38
6.38
6.38
6.38
162
162
162
162
HU363RB
HU364
HU364RB
F5
21.25
29.00
29.25
540
737
743
8.50
17.13
17.25
216
435
438
10.50
18.50
18.63
267
470
473
6.38
8.25
8.50
162
210
216
HU365
HU365R
HU366
HU366R
HU367
E4
50.25
50.31
50.25
50.31
69.13
1276
1278
1276
1278
1756
27.63
27.88
27.63
27.88
36.62
702
708
702
708
930
2763
27.88
27.63
27.88
36.62
702
708
702
708
930
10.13
10.13
10.13
10.13
17.75
257
257
257
257
451
HU367R
HU368
HU368R
F5
69.13
69.13
69.13
1756
1756
1756
36.62
36.62
36.62
930
930
930
36.62
36.62
36.62
930
930
930
17.75
17.75
17.75
451
451
451
HU461
HU462 F6 20.50
20.50
521
521
14.75
14.75
375
375
16.13
16.13
410
410
6.85
6.85
174
174
HU463
HU464 F5 20.50
29.00
521
737
14.75
23.25
375
591
16.13
24.88
410
632
6.85
8.75
174
222
HU465
HU466 E4 50.25
50.25
1276
1276
33.88
33.88
861
861
33.88
33.88
861
861
10.13
10.13
257
257
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
© 2009 Schneider Electric
All Rights Reserved
40
11/2009
W
W/H
H
H
H
D
D
Typical NEMA Type 4X Fiberglass
Reinforced Polyester and Krydon
Typical NEMA Types 7 and 9
Typical NEMA Types 4, 4X, 5, 12, and 12K
W
D
W
Table 30: Dimensions
Catalog Number Series
Approximate Dimensions
H W W/H D
in. mm in. mm in. mm in. mm
H461AWK
H461DS
H462AWK
H462DS
F6
20.50
20.82
20.50
20.82
521
529
521
529
14.75
15.08
14.75
15.08
375
383
375
383
6.80
6.80
6.13
6.80
173
173
156
173
6.96
6.96
177
177
H221AWK, A
H221DS
H221-2AWK
F6
14.60
14.93
16.50
371
379
419
6.63
7.22
9.00
168
183
229
7.55
8.67
10.50
192
220
267
4.96
5.11
7.00
125
130
178
H222AWK, A
H222DS
H223AWK, A
H223DS
F6
14.60
14.93
20.50
20.82
371
379
521
529
6.63
7.22
9.00
9.36
168
183
229
238
7.55
8.67
10.50
11.25
192
220
267
286
4.96
5.11
7.00
6.97
125
130
178
177
H224AWK, A
H224DS F6 29.00
29.00
737
737
17.25
17.75
438
451
18.63
19.25
473
489
8.75
8.88
216
226
H225AWK, DS
H225NAWK, NDS E4 46.25
46.25
1175
1175
26.25
26.25
667
667
26.25
26.25
667
667
10.13
10.13
259
259
H225XKA C2 22.56 573 10.88 276 10.88 276 7.75 197
H226AWK, DS
H226NAWK, NDS
H227AWK, NAWK
H228AWK, NAWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
H265AWK, DS
H266AWK, A, DS
H267AWK, NAWK
H268AWK, NAWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
H321AWK, A
H321DS
H322AWK, A
H322DS
F6
14.60
14.93
14.60
14.93
1756
379
371
379
6.63
7.22
6.63
7.22
168
183
168
183
7.55
8.67
7.55
8.67
192
220
192
220
4.96
5.11
4.96
5.11
125
130
125
130
H323AWK, A
H323DS F6 20.50
20.82
521
529
9.00
9.36
229
238
10.50
11.25
267
286
7.00
6.97
178
177
H324AWK, A, DS
H325AWK, DS
H325NAWK, NDS
E4
29.00
46.25
46.25
737
1175
1175
17.25
26.25
26.25
438
667
667
18.63
26.25
26.25
473
667
667
8.75
10.13
10.13
216
259
259
H326AWK, DS
H326NAWK, NDS
H327AWK, NAWK
H328AWK, NAWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
H361AWA
H361AWC F7 16.50
16.50
419
419
9.00
9.00
229
229
10.50
10.50
267
267
7.00
7.00
178
178
H361AWK, A, DS F6 14.60 371 6.63 168 7.55 192 4.96 125
H361DF
H361DX F1 16.50
19.40
419
493
11.00
11.40
279
290
11.00
11.40
279
290
8.80
8.60
224
218
H361-2AWK, A F6 16.50 419 9.00 229 10.50 267 7.00 178
H362AWK, A
H362DS
H362AWA
H362AWC
F7
16.50
16.87
16.50
16.50
419
428
419
419
9.00
8.92
9.00
9.00
229
227
229
229
10.50
10.81
10.50
10.50
267
275
267
267
7.00
6.97
7.00
7.00
178
177
178
178
H362AWH F6 16.50 419 9.00 229 10.50 267 7.00 178
H364, N
H364RB, NRB F5 29.00
29.25
737
743
17.13
17.25
436
438
18.50
18.63
470
473
10.13
8.50
257
216
H365, N
H365R, NR
H366, N
H366NR, R
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
27.63
27.88
27.63
27.88
702
708
702
708
27.63
27.88
27.63
27.88
702
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
H367, N
H367NR, R
H368, N
H368NR, R
E4
69.13
69.13
69.13
69.13
1756
1756
1756
1756
36.62
36.62
36.62
36.62
930
930
930
930
36.62
36.62
36.62
36.62
930
930
930
930
17.75
17.75
17.75
17.75
451
451
451
451
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Heavy Duty Safety Switches
General Information
41
11/2009
© 2009 Schneider Electric
All Rights Reserved
W
W/H
H
H
H
D
D
Typical NEMA Type 4X Fiberglass
Reinforced Polyester and Krydon
Typical NEMA Types 7 and 9
Typical NEMA Types 4, 4X, 5, 12, and 12K
W
D
W
Table 31: Dimensions
Catalog Number Series
Approximate Dimensions
H W W/H D
in. mm in. mm in. mm in. mm
H60XFA
H100XFA E1 15.93
15.93
405
405
9.87
9.87
251
251
9.87
9.87
251
251
6.96
6.96
177
177
H221AWK, A
H221DS
H221-2AWK
F6
14.60
14.93
16.50
371
379
419
6.63
7.22
9.00
168
183
229
7.55
8.67
10.50
192
220
267
4.96
5.11
7.00
125
130
178
H222AWK, A
H222DS
H223AWK, A
H223DS
F6
14.60
14.93
20.50
20.82
371
379
521
529
6.63
7.22
9.00
9.36
168
183
229
238
7.55
8.67
10.50
11.25
192
220
267
286
4.96
5.11
7.00
6.97
125
130
178
177
H224AWK, A
H224DS F6 29.00
29.00
737
737
17.25
17.75
438
451
18.63
19.25
473
489
8.75
8.88
216
226
H225AWK, DS
H225NAWK, NDS E4 46.25
46.25
1175
1175
26.25
26.25
667
667
26.25
26.25
667
667
10.13
10.13
259
259
H225XKA C2 22.56 573 10.88 276 10.88 276 7.75 197
H226AWK, DS
H226NAWK, NDS
H227AWK, NAWK
H228AWK, NAWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
H265AWK, DS
H266AWK, A, DS
H267AWK, NAWK
H268AWK, NAWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
H321AWK, A
H321DS
H322AWK, A
H322DS
F6
14.60
14.93
14.60
14.93
1756
379
371
379
6.63
7.22
6.63
7.22
168
183
168
183
7.55
8.67
7.55
8.67
192
220
192
220
4.96
5.11
4.96
5.11
125
130
125
130
H323AWK, A
H323DS F6 20.50
20.82
521
529
9.00
9.36
229
238
10.50
11.25
267
286
7.00
6.97
178
177
H324AWK, A, DS
H325AWK, DS
H325NAWK, NDS
E4
29.00
46.25
46.25
737
1175
1175
17.25
26.25
26.25
438
667
667
18.63
26.25
26.25
473
667
667
8.75
10.13
10.13
216
259
259
H326AWK, DS
H326NAWK, NDS
H327AWK, NAWK
H328AWK, NAWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
H361AWA
H361AWC F7 16.50
16.50
419
419
9.00
9.00
229
229
10.50
10.50
267
267
7.00
7.00
178
178
H361AWK, A
H361DS F6 14.60
14.93
371
379
6.63
7.22
168
183
7.55
8.67
192
220
4.96
5.11
125
130
H361DF
H361DX F1 16.50
19.40
419
493
11.00
11.40
279
290
11.00
11.40
279
290
8.80
8.60
224
218
H361-2AWK, A
H362AWK, A
H362DS
F6
16.50
16.50
16.87
419
419
428
9.00
9.00
8.92
229
229
227
10.50
10.50
10.81
267
267
275
7.00
7.00
6.97
178
178
177
H362AWA
H362AWC
H362AWH
F6
16.50
16.50
16.50
419
419
419
9.00
9.00
9.00
229
229
229
10.50
10.50
10.50
267
267
267
7.00
7.00
7.00
178
178
178
H364, N
H364RB, NRB F5 29.00
29.25
737
743
17.13
17.25
436
438
18.50
18.63
470
473
10.13
8.50
257
216
H365, N
H365R, NR
H366, N
H366R, NR
E4
50.25
50.31
50.25
50.31
1276
1278
1276
1278
27.63
27.88
27.63
27.88
702
708
702
708
27.63
27.88
27.63
27.88
702
708
702
708
10.13
10.13
10.13
10.13
257
257
257
257
H367AWK, NAWK
H368AWK, NAWK E4 69.13
69.13
1756
1756
36.62
36.62
930
930
36.62
36.62
930
930
17.75
17.75
451
451
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Heavy Duty Safety Switches
General Information
42
11/2009
W
W/H
H
H
H
D
D
Typical NEMA Type 4X Fiberglass
Reinforced Polyester and Krydon
Typical NEMA Types 7 and 9
Typical NEMA Types 4, 4X, 5, 12, and 12K
W
D
W
Table 32: Dimensions
Catalog Number Series
Approximate Dimensions
H W W/H D
in. mm in. mm in. mm in. mm
H461AWK
H462AWK
H462DS
H463AWK
F6
20.50
20.50
20.82
20.50
521
521
529
521
14.75
14.75
15.08
14.75
375
375
383
375
16.13
16.13
16.85
16.13
410
410
428
410
6.80
6.80
6.97
6.80
173
173
177
173
H463DS
H464AWK
H464DS
F6
20.82
29.00
29.00
529
737
737
15.08
23.25
23.75
383
591
603
16.85
24.88
25.25
428
632
641
6.97
8.75
8.88
177
222
226
H465AWK E4 46.25 1175 32.50 826 32.50 826 10.13 259
H663AWK
H663DS
H664AWK
H664DS
F6
20.50
20.82
29.00
29.00
521
529
737
737
14.75
15.08
23.25
23.75
375
383
591
603
16.13
16.85
24.88
25.25
410
428
632
641
6.80
6.97
8.75
8.88
173
177
222
226
HU265AWK,DS
HU266AWK, DS
HU267AWK
HU268AWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
HU361AWK, A
HU361DS F6 14.60
14.93
371
379
6.63
7.22
168
183
7.55
8.67
192
220
4.96
5.11
125
130
HU361DSWA
HU361DSWC F7 16.87
16.87
428
428
8.92
8.92
227
227
10.81
10.79
275
274
5.11
5.11
130
130
HU361DF
HU361DX F1 16.50
19.40
419
493
11.00
11.40
279
290
11.00
11.40
279
290
8.80
8.60
224
218
HU362AWH
HU362AWK, A
HU362DS
F6
16.50
16.50
16.87
419
419
428
9.00
9.00
8.92
229
229
227
10.50
10.50
10.81
267
267
265
7.00
7.00
6.97
178
178
177
HU362DSWA
HU362DSWC F7 16.87
16.87
428
428
8.92
8.92
227
227
10.81
10.79
275
274
5.11
5.11
130
130
HU362DF
HU362DX F1 16.50
19.40
419
493
11.00
11.40
279
290
11.00
11.40
279
290
8.80
8.60
224
218
HU363AWA
HU363AWC F7 20.50
20.50
521
521
9.00
9.00
229
229
10.50
10.50
267
267
7.00
7.00
178
178
HU363AWK, A
HU363DS F6 20.50
20.82
521
529
9.00
9.36
229
238
10.50
11.25
267
286
7.00
6.97
178
177
HU363DF
HU363DX F1 24.80
25.25
630
641
13.70
11.40
348
290
13.70
11.40
348
290
12.00
8.60
305
218
HU364DF E1 31.30 795 26.30 668 26.30 668 11.80 300
HU364AWK, A
HU364DS, SS F6 29.00
29.00
737
737
17.25
17.75
438
451
18.63
19.25
473
489
8.75
8.88
216
226
HU365AWK, DS
HU366AWK, DS
HU367AWK
HU368AWK
E4
46.25
46.25
69.13
69.13
1175
1175
1756
1756
26.25
26.25
36.62
36.62
667
667
930
930
26.25
26.25
36.62
36.62
667
667
930
930
10.13
10.13
17.75
17.75
259
259
451
451
HU461AWK
HU461DS
HU462AWK
HU462DS
F6
20.50
20.82
20.50
20.82
521
529
521
529
14.75
15.08
14.75
15.08
375
383
375
383
16.13
16.85
16.13
16.85
410
428
410
428
6.80
6.97
6.80
6.97
173
177
173
177
HU463AWK
HU463DS
HU464AWK
HU464DS
F6
20.50
20.82
29.00
29.00
521
529
737
737
14.75
15.08
17.25
17.75
375
383
438
451
16.13
16.85
18.63
19.25
410
428
473
489
6.80
6.97
8.75
8.88
173
177
216
226
HU465AWK E4 46.25 1175 32.50 826 32.50 826 10.13 259
H663AWK
H663DS
H664AWK
H664DS, RWK
F6
20.50
20.82
29.00
29.00
521
529
737
737
14.75
15.08
23.25
23.75
375
383
591
603
16.13
16.85
24.88
25.25
410
428
632
641
6.80
6.97
8.75
8.88
173
177
222
226
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
43
11/2009
© 2009 Schneider Electric
All Rights Reserved
DOUBLE THROW SAFETY SWITCHES CONTENTS
Product Description.............................................................................. 44
Construction ......................................................................................... 44
Enclosures............................................................................................ 44
Accessories .......................................................................................... 45
Application ...................................................................................... 45
Standards ....................................................................................... 46
Technical Data................................................................................ 46
Service Grounding Kit..................................................................... 49
Solid Neutral Assembly .................................................................. 49
Electrical Interlocks......................................................................... 49
Class R Fuse Kits ........................................................................... 50
Lock-On Provision .......................................................................... 50
Rain-Proof Bolt-On Hubs................................................................ 50
Watertight Hubs.............................................................................. 50
Dimensions........................................................................................... 51
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Double Throw Safety Switches
44
11/2009
Product Description
Double throw safety switches are designed to transfer a load from one
power source to another power source. 30–100 A F Series switches can be
field-converted to transfer a power source from one load to another.
Construction
Modular-design switch handle, lock -plate, and switch mechanism; line
and load bases are available for field replacement
Meets NEMA hp ratings
UL Listed short circuit current ratings up to 200 ka (using Class R, J, or T
fuses see UL Listed Short Circuit Current Ratings table on page 45)
UL Listed as suitable for use as service equipment
Fusible and non-fusible switches available
May be padlocked in the “ON” or “OFF” position
Padlock provisions in the center “OFF” position on 82,000, 92,000, DT,
and DTU lines
Padlock provisions in both “ON” positions on 92,000 line
Visible blades for positive indication that the switch is “OFF”
Electrical interlock and neutral assembly (for two- and three-pole
switches) kit is available for field-installation
Quick-make, quick-break operating mechanism on F Series, 82,000, DT,
and DTU lines. Load make/break
Slow-make, slow-break operating mechanism on 92,000 line. Non-load
make/break
Lugs suitable for aluminum or copper conductors. See page 46 for
additional lug data
Dual cover interlock on DT and DTU F Series and NEMA Type 1
82,000 line E Series devices, with defeat mechanism
NEMA Type 3R top endwalls on 30–200 A switches have bolt-on hub
provisions
Tangential knockouts alleviate the need for conduit offsets or bends
Type 304 Stainless Steel (NEMA Types 4, 4X, and 5)
Enclosures
Indoor general purpose (NEMA Type 1)
Outdoor general purpose (NEMA Type 3R)
Indoor dusttight, driptight (NEMA Type 12)
Indoor, outdoor watertight, dusttight (NEMA Types 4, 4X, and 5)
Gray baked enamel finish electrodeposited on clean, phosphatized steel
(NEMA Types 1, 3R, and 12)
30–100 A DT, DTU (Series F)
NEMA Type 1
82,000 Line
NEMA Type 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
45
11/2009
© 2009 Schneider Electric
All Rights Reserved
Accessories
Bolt-on hubs for rainproof applications. Switches with RB suffix accept
3/4 in. through 2-1/2 in. bolt-on hubs. Switches with R suffix have blank
endwalls and accept 3 in. through 4 in. bolt-on hubs.
Equipment grounding kits available for field-installation.
Field- or factory-installed (depending on series) electrical interlocks
(2 N.O./2 N.C. contacts). F Series electrical interlocks are available for
field- or factory-installation.
Factory-installed neutral assembly. DTU devices (E Series only) are
supplied with factory-installed insulated, grounded, and bonded neutral
assembly.
Lock-on provisions are standard on DT, DTU (F Series) and 92,000 line
switches. Available as an option for factory-installation on DTU
(E Series) and 82,000 line switches.
Application
Double throw safety switches are designed for:
Residential, light commercial, and industrial installations
Up to 600 V dc and 600 Vac maximum
Up to 100,000 rms symmetrical amperes
30–600 A
NEMA Types 1, 3R, 4, 4X, 5, or 12 enclosures
82,000 Line
NEMA Type 1
Line
Line
Load
Diagram 1
Non-Fusible
Double Throw
Switch
Fusible Single
Throw Switch
Line
Line
Load
Fusible Single
Throw Switch
Non-Fusible
Double Throw
Switch
Fusible Single
Throw Switch
Diagram 2
NOTE: Diagrams 1 and 2 illustrate methods of applying fuses
to non-fusible double throw switches when required.
Table 33: UL Listed Short Circuit Current Ratings
Switch Type Ampere
Rating
Voltage
Rating
UL Listed
Fuse Class
Short Circuit
Current Rating 1
(A)
1Rating applies to AC only. The UL Listed short circuit current rating for non-fusible switches is
based on the switch being used in conjunction with the corresponding fuse type. Evaluation of
non-fusible switches in conjunction with molded case circuit breakers has not been performed
above 100 A.
Type DT (Series F) 30–100 A 240 V or 600 V H, K 10,000
R, J 200,000
Type DTU 2
(Series F)
230–100 A switches are also suitable for use on a circuit capable of delivering not more than (A)
18 kA, 600 Vac maximum when protected by Type FH circuit breaker rated 30–100 A maximum or
(B) 14 kA, 600 Vac maximum when protected by Type FA circuit breaker rated 30–100 A maximum.
30–100 A 240 V or 600 V H or K 10,000 3
3Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used
ahead of a non-fusible safety switch when there is up to 10 kA short circuit current available.
R, J or T 200,000
DTU224NRB 200 A 240 V H, K 10,000 3
DTU324N and
DTU324NRB
(Series E)
200 A 240 V
H, K 10,000 3
R, J 100,000
Type 82,000 all 240 V H, K 10,000 3
R, J 100,000 4
4400 A 82,000 switch is only 10 kA.
600 V H, K 10,000 3
Type DTU (A Series) 600 A 240 V or 600 V H, K 10,000
R, J, T 100,000
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Double Throw Safety Switches
46
11/2009
Standards
Double throw safety switches are manufactured in accordance with
standards published in:
UL 98, Standard for Enclosed and Dead Front Switches; UL Listed
under File E2875
NEMA Standards Publication KS1-2001 Enclosed and Miscellaneous
Distribution Equipment Switches (600 Volts Maximum)
Technical Data
Table 34: Systems
Switch Type Non-Fusible Poles Neutral Load Make/Break Rated
DT, DTU 2 or 3 Field-installable 1
1Neutrals are insulated and may be bonded.
Yes
82,000 Line 2, 3, or 4 Factory-installed only Yes
92,000 Line 2, 3, or 4 Factory-installed only No
Table 35: Terminal Lug Data for Type DT, DTU (Series F) Double
Throw Safety Switches
Switch
Wires
per
Phase
NEMA Types 1, 3R, 4, 4X, 12
Optional
Copper
Lugs
Wire Range Wire
Bending Space Per
NEC Table 373-6
AWG/kcmil
Standard
Lug
Wire Range
AWG/kcmil
Optional
Compression
Lug
Field-Installed
30–60 A
Type DT, DTU
(Series F)
1 12–2 Al or 14–2 Cu 12–2 Al or
14–2 Cu
C10-14, D8-14,
or E6-14 1
1Thomas and Betts® catalog numbers.
Refer to Digest
for selection.
100 A
Type DT, DTU
(Series F)
1 12–1/0 Al or 14–1/0 Cu 12–1/0 Al or
14–1/0 Cu VCEL02114S1 2
2Hubbell Versa-Crimp® catalog numbers.
Refer to Digest
for selection.
Table 36: Terminal Lug Data for Types 82,000 and for A and E-
Series DTU devices 1
1200–600 A switches suitable for 75°C conductors.
Switch Wires per
Phase
Wire Range Wire
Bending Space
Per NEC Table 373-6
AWG/kcmil
Lug Wire
Range
AWG/kcmil
Optional
Compression
Lugs
Field-Installed
30 A (Series T4) 2
230 A switches suitable for 60°C or 75°C conductors.
1 14–8 Al/Cu
12–2 Al
or
14–2 Cu
200 1 6–300 Al/Cu 6–300 Al/Cu VCEL030516H1 3
3Hubbell Versa-Crimp catalog numbers.
400
1
or
2
1/0–600 Al/Cu
or
1/0–300 Al/Cu
1/0–600 Al/Cu
600 2 250–500 Al/Cu 250–500 Al/Cu
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
47
11/2009
© 2009 Schneider Electric
All Rights Reserved
Table 37: 240 Volt
System Rating
(A)
Current
Series
NEMA
Type 1
NEMA
Type 3R
NEMA Types 4,4X,5
304 Stainless Steel
NEMA Type 12
Gasketed
Horsepower Ratings 1 2
1Refer to page 7-31 of Digest 175 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time
delay characteristics.
2Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
240 Vac
250 V dc 3
3For switching dc, use two switching poles.
Std. Max.
Catalog Number 3Ø 1Ø 3Ø
Fusible Two-Pole 240 Vac 250 V dc
100 F DT223 DT223RB 7.5 15 4
4If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.
15 30 420
Three-Pole 240 Vac 250 V dc
30
60
100
F
DT321
DT322
DT323
DT321RB
DT322RB
DT323RB
——
1.5 5
3 5
7.5 5
5Use outer switching poles.
3
4
7.5 4
15 4
3 5
10 5
15 5
7.5 4
15 4
30 4
5
10
20
Non-Fusible Two-Pole 240 Vac 250 V dc
60
100
FDTU222
DTU223
DTU223RB ——
10
15
10 6
20 6
6Maximum rating.
30 T4 92251 7
7240 Vac only.
——— —
200 E 82254 8
8250 V dc rated.
DTU224NRB7 8 9 H82254 15——— —
15——— —
400 A 82255 7 8 82255R 7H82255 7——— —
Three-Pole 240 Vac 250 V dc
30
60
100
F
DTU321
DTU322
DTU323
DTU323RB
——
3 4
5 5
10 5
15 5
10 4
15 4
30 4
5 6
10 6
20 6
30 T4 92351 7 ——— —
200 E 82354 7DTU324NRB 7 9
9Neutral included with device.
H82354 7 10
10 Suitable for use as service equipment.
—15—— —
200 E DTU324N 7 9 —— —15
400 A 82355 7 8 82355R 7 8 H82355 7 8 ——— —
600 A DTU326 DTU326R 125 — 50
Four-Pole 240 Vac
30 T4 92451 7 ——— —
200 E 82454 82454R 8H8245411
11 Hp rating applies only to H82454.
—15
11 —— —
400 A 82455 8 82455R H82455 ——— —
600 A DTU426 DTU426R 125 — 50
Line
Line
Load
Line
Line
Load
Line
Line
Load
Line
Line
Load
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
© 2009 Schneider Electric
All Rights Reserved
48
11/2009
Table 38: 600 V
System Rating
(A)
Current
Series
NEMA
Type 1
NEMA
Type 3R
NEMA
Type 4,4X,5
304 Stainless
Steel
NEMA Type 12
Gasketed
Horsepower Ratings 1
2
240 Vac 480 Vac 600 Vac V dc3
std max std max std max 250 600
Catalog Number 333Ø 3Ø
Fusible Three-Pole 600 Vac 600 V dc
30 F DT361 DT361RB 5 15 7.5 20 5 15
60 F DT362 DT362RB 15 30 15 50 — 30
100 F DT363 DT363RB 25 60 30 75 — 50
Non-Fusible Three-Pole 600 Vac 600 V dc 43434
30 F DTU361 DTU361RB ——5 10 7.5 20 10 30 5 15
60 F DTU362 DTU362RB DTU362DS DTU362AWK 510 20 625 50 730 60 710 30
100 F DTU363 DTU363RB DTU363DS DTU363AWK 520 40 840 75 8 9 40 75 820 50
200 E 8234410
11 82344RB 10 11 82344DS1012 H8234410
13
14 15 14 ——
400 A 82345 11 82345R 11 15 82345DS 11 H82345 — — — — —
600 A DTU366 11 DTU366R 11 DTU366AWK 11 — 125 — 250 — 350 50
Non-Fusible Four-Pole 600 Vac 600 V dc 2Ø 3Ø 2Ø 2Ø 3Ø
60 F DTU462 Use NEMA
Type 12
DTU462DS DTU462AWK 520 20 40 50 50 60 10 30
100 F DTU463 DTU463DS DTU463AWK 530 40 50 75 50 75 20 30
200 E 82444 11 82444R
11 82444DS 11 H82444 10
11 13 ——— — ——
400 A 82445 11 15 82445R 15 H82445 15 ——— — ——
600 A DTU466 11 DTU466R 11 ——— 125 — 250 — 350 50
Non-Fusible Six-Pole 600 Vac 600 V dc 1Ø 3Ø 1Ø 1Ø 3Ø
60 F DTU662AWK 5—20— 50 —601030
100 F DTU663AWK 5—40— 75 —752050
1Refer to page 7-31 of Digest 175 for additional motor application data. The starting current of motors of more than standard horsepower may require the use of fuses with appropriate time
delay characteristics.
2Std.—Using fast-acting one time fuses. Max.—Using dual element time delay fuses.
3If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.
4Use outer switching poles.
5Complete rating on switch is NEMA Types 3R or 12. For 3R applications, remove drain screw from bottom endwall.
6Maximum Hp is 15 for corner grounded delta systems.
7Use 75oC #4 Cu or #2 Al conductors only.
8Use 75oC #1 Cu conductors only.
9Maximum Hp is 60 for corner grounded delta systems.
10 480 Vac maximum only, 250 V dc.
11 250 V dc rated.
12 Not UL Listed.
13 Not suitable for use as service equipment.
14 Standard Hp rating.
15 600 Vac max.
Line
Line
Load
Line
Line
Load
Line
Line
Load
Line
Line
Load
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
49
11/2009
© 2009 Schneider Electric
All Rights Reserved
Service Grounding Kit
Field-installed equipment grounding kits are required for service equipment use.
Solid Neutral Assembly
Factory- or field-installed 30, 60, 100, 400, and 600 A switches
UL Listed
Factory-installed on 200 A 82,000 Series switches. Not UL Listed
NOTE: To order, add suffix “N” to standard catalog number.
Electrical Interlocks
Not available on 92,000 Series double throw switches
Factory- or field-installed on all 30, 60, 100, and 600 A DTU Series
switches and 400 A 82,000 Series switches. UL Listed
Factory-installed on 200 A 82,000 Series switches. Not UL Listed
Electrical interlocks are furnished with two N.O. / N.C. contacts and are
installed in both “ON” positions. To order, add suffix “EI” to standard
catalog number
Table 39: Service Grounding Kit
Switch
Field-Installed Service
Grounding Lug Kit
Catalog Number
Terminal Data
AWG/kcmil
30–60 A Types DT or DTU (Series F) Included (3) 14–2 Cu/Al
100 A Types DT or DTU (Series F) Included (3) 14–1/0 Cu/Al
30 A Type 92,000 DT30SG (4) 14–4 Cu/Al
200 A Type 82000 and DTU (Series E) DT100SG (3) 14–1/0 Cu/Al
400 A Type 82000 PKOGTA2 (2 required) (4) 10–2/0 Cu or
(4) 6–2/0 Al
600 A Type 82000 (Series A) DS468GKD 6–250kcmil
Table 40: Neutral Assembly
Switch
Field-Installed
Standard
Neutral Kit
Catalog Number
Terminal
Data
AWG/kcmil
Field-Installed
Copper only
Neutral Kit
Catalog Number
Terminal
Data
AWG/kcmil
30–100 A Type DT, DTU
(Series F) (2- and 3-pole
switches only)
SN0310 14–1/0 Al/Cu SN0310C 14–1/0 Cu
30 A (Series T4) (2- and 3-
pole switches only)
1
1For Type 82,000 switches, neutral is available factory-installed on two- and three-pole double throw switches.
Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of
the switch. For DTU switches, neutral is factory-installed in standard device and is UL Listed.
1——
200 A Type 82000 and
DTU (Series E) 2
2Neutral assembly catalog number DT200N can be added to four-pole Type 82000 switches in the field.
11
——
400 A Type 82000 DT400N
(1) 4–600
kcmil or
(2) 1/0–250
kcmil
——
600 A Type DTU (Series A) DT600NKD 250–500kcmil
Table 41: Electrical Interlocks
Switch Field-Installed Electrical Interlock
Kit Catalog Number1
1Electrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact;
“2” indicates two normally open and two normally closed contacts.
30–100 A Type DT, DTU (Series F) EIK1, EIK2 2
230–100 A Type DT, DTU (Series F) switches contain two separate switching mechanisms. Each mechanism
will accept an electrical interlock. Some applications may therefore require two electrical interlocks.
200 A Type 82000 and DTU (Series E) 3
3Electrical interlock EK400DTU2 can be added to four-pole Type 82000 switches in the field.
See text above.
400 A Type 82000 EK400DTU2
600 A Type DTU (Series A) DS200EK2D
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Double Throw Safety Switches
50
11/2009
Class R Fuse Kits
When installed, this kit rejects all but Class R fuses. Kits are available for
field installation. For factory installation, add “CLR” suffix to catalog number.
Lock-On Provision
UL Listed
30–100 A type DT or DTU (Series F) and type 92,000 included on
standard device
Type 82,000 and 200 A DTU (Series E) available factory-installed. Add
SPLO to catalog number
Table 42: Class R Fuse Kits
Switch Series Number Class R Fuse Kit Catalog Number
Class R Fuse Kits—240 V (two kits per three-pole switch)
30 A F5 RFK03
60 A F5 RFK06
100 A F5 RFK10
Class R Fuse Kits—600 V (two kits per three-pole switch)
30 A F5 RFK06
60 A F5 RFK06H
100 A F5 RFK10
Table 43: Rain-Proof Bolt-On Hubs
Conduit
Size 3/4 11-1/41-1/222-1/233-1/24 Closing
Cap
Hub Cat.
No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP
Table 44: Watertight Hubs (For use on NEMA Types 4, 4X and 5
Stainless Steel and NEMA Type 12 enclosures.)
Conduit Trade
Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4
Standard-Zinc
Hub Catalog
Number
H050 H075 H100 H125 H150 H200 H250 H300 H350 H400
Chrome
Plated Hub
Catalog
Number
H050CPH075CPH100CPH125CPH150CPH200CP — — —
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
51
11/2009
© 2009 Schneider Electric
All Rights Reserved
W
W/H D
H
W
W/H D
H
W
W/H D
H
Typical NEMA Type 3R
Typical NEMA Types 4, 4X, 5, and 12
Typical NEMA Type 1
Table 45: 30–100 A Types DT, DTU (Series F) Approximate
Dimensions
Catalog
Number Series H W W/H D
in. mm in. mm in. mm in. mm
DT223 F5 38.00 965 9.88 251 11.13 283 6.75 171
DT223RB F5 38.00 965 6.87 174 8.12 206 6.60 168
DT321 F5 38.00 965 10.25 260 11.50 292 6.75 171
DT321RB F5 38.00 965 10.25 260 11.80 300 6.60 168
DT322 F5 38.00 965 10.25 260 11.50 292 6.75 171
DT322RB F5 38.00 965 10.25 260 11.80 300 6.60 168
DT323 F5 38.00 965 9.88 251 11.13 283 6.75 171
DT323RB F5 38.00 965 6.87 174 8.12 206 6.60 168
DT361 F5 38.00 965 10.25 260 11.50 292 6.75 171
DT361RB F5 38.00 965 10.25 260 11.80 300 6.60 168
DT362 F5 38.00 965 10.25 260 11.50 292 6.75 171
DT362RB F5 38.00 965 10.25 260 11.80 300 6.60 168
DT363 F5 38.00 965 9.88 251 11.13 283 6.75 171
DT363RB F5 38.00 965 6.87 174 8.12 206 6.60 168
DTU222 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU223 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU223RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU321 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU322 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU323 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU323RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU361 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU361RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU362 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU362AWK F6 29.94 760 10.25 260 11.96 304 6.93 176
DTU362DS F6 30.26 769 10.25 260 11.50 292 7.12 181
DTU362RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU363 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU363AWK F6 29.94 760 10.25 260 11.96 304 6.93 176
DTU363DS F6 30.26 769 10.25 260 11.50 292 7.12 181
DTU363RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU462 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU462AWK F6 30.26 769 15.50 394 16.75 425 7.12 181
DTU462DS F6 30.26 769 15.50 394 16.75 425 7.12 181
DTU463 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU463AWK F6 30.26 769 15.50 394 16.75 425 7.12 181
DTU463DS F6 30.26 769 15.50 394 16.75 425 7.12 181
DTU662AWK F6 30.26 769 15.50 394 16.75 425 7.12 181
DTU663AWK F6 30.26 769 15.50 394 16.75 425 7.12 181
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Double Throw Safety Switches
52
11/2009
W
W/H
D
H
W
H
D
W/H
Typical NEMA Type 1
DTU—200 A
NEMA Type 3R
Table 46: 30, 200–600 A Types 82,000 and E-Series DTU devices,
NEMA Types 1 and 3R Approximate Dimensions
Catalog
Number Series H W W/H D
in. mm in. mm in. mm in. mm
DTU224NRB 1
1250 V dc rated.
E1 32.50 826 20.63 524 24.00 610 10.63 270
82254 1E1 30.88 784 15.75 400 19.63 499 9.75 248
82254NW 1E1 30.88 784 20.00 508 23.88 607 11.75 298
82344 1E2 30.88 784 20.00 508 23.88 607 11.75 298
82344RB 1E1 32.50 826 20.63 524 24.00 610 10.63 270
82354 E1 30.88 784 20.00 508 23.88 607 11.75 298
92251 T4 10.00 254 8.00 203 9.75 248 4.75 121
82344DS E1 30.88 784 20.00 508 23.88 607 11.75 298
DTU324N E1 32.50 826 24.50 622 26.25 667 10.63 270
DTU324NRB E1 32.50 826 24.50 622 26.25 667 10.63 270
H82344 E2 32.50 826 24.50 622 26.25 667 10.63 270
H82444 1E2 32.50 826 30.21 767 33.61 854 10.63 270
H82454 E3 32.50 826 30.21 767 33.61 854 10.63 270
82454 E3 38.00 965 29.62 753 33.02 839 10.63 270
82444 E3 38.00 965 29.62 753 33.02 839 10.63 270
82454R 1E3 38.00 965 29.62 753 33.02 839 10.63 270
82444R E3 38.00 965 29.62 753 33.02 839 10.63 270
H82254 E3 32.50 826 24.50 622 26.25 667 10.63 270
H82354 E3 32.50 826 24.50 622 26.25 667 10.63 270
82444DS 1E3 38.00 965 29.62 753 33.02 839 10.63 270
82255 1A1 38.50 978 26.10 663 29.51 750 10.63 270
82255R A1 39.00 991 26.62 676 30.02 763 10.63 270
82345 1A1 38.50 978 26.10 663 29.51 750 10.63 270
82345DS 1A1 39.00 991 26.62 676 30.02 763 10.63 270
82345R 1A1 39.00 991 26.62 676 30.02 763 10.63 270
82355 1A1 38.50 978 26.10 663 29.51 750 10.63 270
82355R 1A1 39.00 991 26.62 676 30.02 763 10.63 270
82445 A1 38.50 978 30.10 765 33.50 851 10.63 270
82445R A1 39.00 991 30.21 767 33.61 854 10.63 270
82455 1A1 38.50 978 30.10 765 33.50 851 10.63 270
82455R A1 39.00 991 30.21 767 33.61 854 10.63 270
H82255 A1 39.00 991 26.62 676 30.02 763 10.63 270
H82345 A1 39.00 991 26.62 676 30.02 763 10.63 270
H82355 A1 39.00 991 26.62 676 30.02 763 10.63 270
H82445 A1 39.00 991 30.21 767 33.61 854 10.63 270
H82455 A1 39.00 991 30.21 767 33.61 854 10.63 270
DTU326 A1 63.31 1608 23.66 601 24.46 621 8.88 226
DTU426 A1 63.31 1608 27.00 686 27.80 706 8.88 226
DTU366 A1 63.31 1608 23.66 601 24.46 621 8.88 226
DTU466 A1 63.31 1608 27.00 686 27.80 706 8.88 226
DTU326R A1 63.76 1619 23.66 601 24.46 621 8.88 226
DTU426R A1 63.76 1619 27.00 686 27.80 706 8.88 226
DTU366R A1 63.76 1619 23.66 601 24.46 621 8.88 226
DTU466R A1 63.76 1619 27.00 686 27.80 706 8.88 226
DTU366AWK A1 63.76 1619 23.66 601 24.46 621 8.88 226
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
53
11/2009
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
© 2009 Schneider Electric
All Rights Reserved
Double Throw Safety Switches
54
11/2009
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Double Throw Safety Switches
55
11/2009
© 2009 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
3100CT0901 © 2009 Schneider Electric All Rights Reserved
Replaces 3100CT9801 dated 12/1999.
11/2009
Schneider Electric
1601 Mercer Road
Lexington, KY 40511 USA
1-888-Square D
1-888-778-2733
www.schneider-electric.us
Square D is a registered trademark of Schneider Electric and/or its affiliates in the United States
and/or other countries. Other marks used herein may be the property of their respective owners.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Navigation menu