240012 34962 Catalog

123195-Attachment 123195-Attachment 123195-Attachment 000262 Batch12 unilog cesco-content

2014-11-11

: Pdf 34962-Catalog 34962-Catalog 000262 Batch12 unilog

Open the PDF directly: View PDF PDF.
Page Count: 114

Download240012  34962-Catalog
Open PDF In BrowserView PDF
The Science of Reliable Control

Timing Devices
Temperature Indicators & Controls
Dust Collector Controls
Custom Machine Controls
Solid State Relays
Liquid Level Controls
Voltage Monitors

N a t i o n a l C o n t r o l s C o r p.

CUSTOM CONTROLS CAPABILITY
AMETEK NCC:
● Designs, engineers, and manufactures high-quality electronic controls for the value-driven and quality-conscious
OEM customer.
● Provides solutions for the growing trend of corporate
downsizing. Its fully turnkey, engineering and manufacturing solutions address the challenge and respond to rapid
technological changes.
● Leads design and manufacture of custom electronic controls and assemblies through day-to-day interaction in
design development in partnership with OEM customers.
● Increases customer satisfaction, confidence and loyalty
through a multi-level, interactive organization that creates
a high degree of mutual dependence.
● Emphasizes micro-controller hardware and software
design in conjunction with analog and digital circuitry.
Let AMETEK NCC be your partner in full-service design and
manufacturing of custom electronic controls and assemblies.

ABOUT NATIONAL CONTROLS
National Controls Corporation (NCC) is a unit of
AMETEK, Inc., a leading global manufacturer of
electronic instruments and electric motors with
annualized sales of more than $1.4 billion. AMETEK
has over 8,500 employees at more than 70 plants
and facilities in the United States and 18 other
countries.
Headquartered in suburban Philadelphia, AMETEK
consists of two operating groups:
Electronic Instruments—a leading manufacturer
of advanced instruments for the aerospace,
process and industrial markets.
Electromechanical—the world’s leading producer
of high-speed, air-moving electric motors for floorcare, aerospace, military, mass transit, business
equipment and medical devices.
AMETEK’s Corporate Growth Plan is based on Four Growth
Strategies: Strategic Acquisitions & Alliances, Global &
Market Expansion, New Products and Operational Excellence.
NCC serves as an excellent example of AMETEK’s Strategic
Acquisitions & Alliances growth strategy. Acquired in January
1999, NCC enhanced AMETEK’s position in electronic
controls for industrial applications.
NCC is part of AMETEK’s Dixson Division, which produces
electronic controls for heavy-vehicle, foodservice, and
industrial markets. AMETEK Dixson is the number-one U.S.
supplier of electronic dashboard instruments for heavy trucks
and other vehicles.
In addition to standard product industrial controls, AMETEK
NCC provides its customers with innovative and proven
product and service solutions. NCC partners with its
customers to better meet their design needs, and satisfy
their requirements for product quality, reliability, and cost
competitiveness.

i

Effective Electronic Controls
and Effective Customer
Support
Sales will understand and represent our
customer’s needs to ensure that they are communicated accurately, and that the price point
and design continues to meet or exceed the
customer’s expectation.
Engineering will translate the customer’s
control requirements into a design that is
reliable, manufacturable, and meets the customer’s needs while complying with industry
and safety agency standards. Our experience in electronic controls provides us with
the ability to offer product enhancements to
improve our customer’s end product.
Manufacturing will build your product as efficiently as possible, maintaining cost structure,
utilizing state-of-the-art manufacturing and
process controls to ensure the highest quality
product.
Effective communication between our customer and the NCC team ensures customer
satisfaction.

OVERVIEW

At National Controls, effective communication
is the key to our success. Whether standard
product or custom, NCC uses a team approach
that involves our customer, sales, engineering, manufacturing, and quality assurance. We
built our business by solving problems. The
lead team member, our customer, defines the
problem. NCC engineering, sales, and manufacturing will solve the problem.

Engineering Support
More than 20 engineers, circuit designers, software
delvelopers, and support staff quickly respond to your
specific application with a standard or custom solution. National Controls provides in-house capability
with:
● Computer-aided design
● Programming for microprocessor-based designs
● Fully equipped model shop and prototyping
capabilities
● On-site, certified testing facilities for UL and CUL.
Equipment and facilities available for FCC and
other agency testing

Manufacturing Support
National Controls manufacturing team gives you:
● Skilled and well-trained work force
● Computer controlled and monitored production
processes
● Computer driven testing systems
● Manufacturing processes using the latest
technology and equipment
● Fully air conditioned manufacturing and storage
environment
● On site screening process
● JIT parts support for your products
● MRP Planning system to support timely
production of your controls
● Quality built into the product
● Suppliers that enhance quality and customer
service
● All products fully tested to verify specification
compliance

ii

Custom Design and Assembly
Surface mount fabrication capability
Automatic insertion equipment
Semi-automated hand insertion stations
Wave soldering equipment
Application specific test and burn-in equipment
Computer based test systems providing manufacturing defect analysis
● Silkscreen and labeling capability
● In-process inspection and test
● 100% final testing
●
●
●
●
●
●

Serving Diverse and Demanding
Partners in Industry
●
●
●
●
●
●
●
●

Compressor
Generator
Batch Processing
Pump/Dispensing
Fire Protection
Packaging
Automotive
Environmental

Opportunity

Customer Focus

Quality, Reliability,
Cost Competitiveness

Value-added Products

Long-term Relationships

iii

Our Quality System
AMETEK NCC has a Quality System that utilizes rigid
control processes throughout the design, development, and
manufacturing process to assure our customers of reliable
products. AMETEK NCC justifies its claim of producing high
quality products by placing emphasis on the following:
1. Design Review—As each product is conceived and its
development is planned, detailed design criteria are thoroughly reviewed by Marketing, Design Engineering, Quality
Assurance, Manufacturing, Product Test Engineering, and
Product Service and Repair personnel to ensure all requirements are met.
2. Supplier Qualification—Every supplier of material that
goes into AMETEK NCC products is evaluated for their
capability to produce and deliver material according to
specified requirements and must maintain an acceptable
performance rating.
3. Incoming Inspection/Test—Materials received
are inspected/tested to ensure they meet all required
specifications.
4. In-Process Inspection/Testing—Inspection and testing
occurs throughout the production process to verify the
following:
● Proper assembly and overall workmanship of products
● Products are calibrated, electrically tested for proper
function and hi-pot per UL standards
● Life tested (products are burned-in to simulate actual
operating conditions)
5. Final Inspection/Test—Finished products are final
inspected/tested to ensure compliance with all AMETEK
NCC customer specifications.
6. Quality Audits—AMETEK NCC departments are audited
for compliance with quality system requirements.
7. Standards Compliance—AMETEK NCC products
are designed to comply with Underwriters Laboratory’s,
Canadian Standards Association’s and the Federal
Communications Commission’s standard requirements
for safety and emissions control. These activities are con-

iv

ducted on a sample basis per MIL-STD-105E
Sampling Standard. The measurement/test equipment used during all product stages are calibrated
per AMETEK NCC’s in-house process that conforms
to MIL-STD-45662 Standard for Calibration Systems
requirements.
8. Documentation—AMETEK NCC’s Quality System
is completely described in our Quality Assurance
Manual which is available upon request along with
our Product Workmanship Standard. Since all
products are final inspected/tested after being 100%
functionally tested during production, AMETEK
NCC also offers a Certificate of Conformance, upon
request, to customers desiring to minimize their
internal process times by eliminating the need to
perform an incoming inspection/test on AMETEK
NCC products.

Total Quality Management
The above eight items highlight AMETEK NCC’s
Quality System. Together with marketing/sales,
customer service, production planning, automated information systems, accounting/finance,
corrective action, training, and statistical process
control,they represent AMETEK NCC’s Total Quality
Management concept.

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . i

Resistance Sensors (Dual Probe)

PRODUCT FINDER . . . . . . . . . . . . . . . . . . . vii

Resistance Sensors (Pump Up Logic with Heater
Burn Out Protection)

TIME DELAY RELAYS . . . . . . . . . . . . . . . . 1-1
Multi-Time Range/Function/Input Voltage

Flatpak DMM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

Multi-Time Range/Function/Input Voltage

1/16 DIN TMM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

Multi-Time Range/Function

TMM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

Multi-Time Range Delay On Make

A1M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

Delay On Make

T1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

Delay On Make (Relay Output)

Q1T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

Delay On Make (Series Load)

Q1T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

Delay On Make (Series Load)

Delay On Make (Alarm Output)

Q1F Alarm Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10

Delay on Make (Series Load)

Q1D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11

Delay On Make

K1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12

Delay On Make

Z1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13

Single Shot

T2 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14

Single Shot

Q2T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15

Models NS210 and NS211 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

Resistance Sensors (Dual Probe)

Models NS129, NS132 and NS139 . . . . . . . . . . . . . . . . . . . . . . . . 2-6

Resistance Sensors (Dual Probe, Dual Logic)

Model NS146 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

Resistance Sensors (Dual Probe, Dual Voltage)
1hp Solid State Output

Model NS141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8

Resistance Sensors (Single Probe, Pump Up Logic
with Time Delayed Output)

Models NS156 and NS159 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9

Resistance Sensors (Low Water Detect Logic)

Model NS157 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

TEMPERATURE MONITORS/CONTROLS 3-1
Digital Temperature Controller

TC140 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

Digital Temperature Controller

TC142 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

Panel Mount Digital Thermometer

Models TM165 and TM166 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6

Digital Temperature Indicator

TM110 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8

Digital Temperature Indicator

TM200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9

Electronic Temperature Controller

TC280 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10

DUST COLLECTOR CONTROLS . . . . . . . 4-1

Single Shot

Intermittent Use Collectors

Q2F Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16

Model T2101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

Single Shot

AC Input, Pulse Cleaning of Bag House Dust
Collectors

K2 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17

Multi-Range Delay On Break (Retriggerable)

T3M Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18

Delay On Break (Retriggerable)

T3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19

Delay On Break (Retriggerable)

Q3T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20

Delay On Break (Retriggerable)

Q3F Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21

Models DNC-T2003 through DNC-T2032. . . . . . . . . . . . . . . . . . 4-4

DC Input, Pulse Cleaning of Bag House Dust
Collectors

Model DNC-T2010-ADC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6

Pulse Jet Dust Collector Control with Extended
Cycle

DNC-T2110 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8

Delay On Break (Retriggerable)

DUSTRONIX™ Core-10/Expander-10 Dust
Collector Controls

Delay On Break (Retriggerable)

DUSTRONIX™ Pressure Differential Meter*

Interval

Intelligent, AC-Input, Pulse Cleaning of Bag
House Dust Collectors

K3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22
Z3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23
S1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24

Interval (Relay Output)

Q4T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25

Interval

Q4F Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-26

Interval

Z4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-27

Repeat Cycle

CKK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-28

Repeat Cycle

Q6F Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-29

Flasher

Q8F Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-30

Repeat Cycle

Z6 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31

Universal Voltage Input Buffer

ASY-INPUT-BUFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32

Fan and Light Control

Model T1517 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33

LIQUID LEVEL CONTROL SERIES . . . . . . 2-1
Resistance Sensors (Single Probe)

Models DNC-T2610-010/020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Model DNC-PS700-A10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12

Models DNC-T2310 and DNC-T2320 . . . . . . . . . . . . . . . . . . . . . 4-14

Intelligent Dust Collector Controller Remote
Input/Output Module

Model DNC-T2300-I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20

Intelligent Dust Collector Controller Remote
Annunciator Panel

Model DNC-T2300-DSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22

SOLID STATE RELAYS, VOLTAGE
MONITORS, CURRENT MONITORS . . . . 5-1
Solid State Power Relays

Model R2025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2

3-Phase Voltage Monitor

Model 240T6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

Single-Phase Undervoltage Monitors

Models 120AZ and 240AZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5

2-20 A Current Monitor

IST-200T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

05SLA and 05SLB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

Resistance Sensors (Dual Probe)

DLA and DLB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

v

* May be purchased separately as an accessory to NCC Dust Collector
Controls, as well as other controllers

TABLE OF CONTENTS

Q1F Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

Models NS127, NS128 and NS143 . . . . . . . . . . . . . . . . . . . . . . . . 2-4

Solid State Cube Timers and Time Delay Relays
OPERATING LOGIC

Delay On Make

Single Shot

Delay On Break
(Retriggerable)

Interval

Repeat Cycle

Multi-Function

OUTPUT TYPE

PACKAGING CONSTRUCTION

MODEL

PAGE

Relay SPDT

2” x 2” cube

Q1T Series (Relay Output)

1-7

Solid state, Norm. Open

2” x 2” cube

Q1T Series (Series Load)

1-8

Solid state, Norm. Open

2” x 2” cube

Q1D Series (Series Load)

1-11

Solid state, Norm. Open

2” x 2” cube

Q1F Series (Series Load)

1-9

Audible alarm

2” x 2” cube

Q1F Alarm Series

1-10

Relay DPDT

8-pin plug in TDR housing

A1M Series

1-5

Relay DPDT

8/11-pin plug in TDR housing

T1 Series

1-6

Relay DPDT

Miniature spade plug in housing

K1 Series

1-12

Relay DPDT

Open board

Z1 Series

1-13

Solid state, Norm. Open

2” x 2” cube

Q2T Series

1-15

Solid state, Norm. Open

2” x 2” cube

Q2F Series

1-16

Relay DPDT or SPDT

8/11-pin plug in TDR housing

T2 Series

1-14

Relay DPDT

Miniature spade plug in housing

K2 Series

1-17

Solid state, Norm. Open

2” x 2” cube

Q3T Series

1-20

Solid state, Norm. Open

2” x 2” cube

Q3F Series

1-21

Relay DPDT

11-pin plug in TDR housing

T3M Series

1-18

Relay DPDT or SPDT

8/11-pin plug in TDR housing

T3 Series

1-19

Relay DPDT

Miniature spade plug in housing

K3 Series

1-22

Relay DPDT

Open board

Z3 Series

1-23

Relay SPDT

2” x 2” cube

Q4T Series

1-25

Solid state, Norm. Open

2” x 2” cube

Q4F Series

1-26

Relay DPDT

8-pin plug in TDR housing

S1 Series

1-24

Relay DPDT

Open board

Z4 Series

1-27

Solid state, Norm. Open

2” x 2” cube

Q6F Series

1-29

Relay DPDT

8-pin plug in TDR housing

CKK Series

1-28

Relay DPDT

Open board

Z6 Series

1-31

Solid state, Norm. Open

2” x 2” cube

Q8F Series

1-30

Relay DPDT

11-pin plug in TDR housing

TMM Series

1-4

Relay DPDT

1/16 DIN panel mount, 11-pin spade type base

TMM Series

1-3

Relay DPDT

DIN rail mount, Flatpak housing

DMM Series

1-2

Liquid Level Controls
OPERATING LOGIC

Pump Down

Pump Up

Programmable Pump
Down/Pump Up
Low Water Detect

vi

OUTPUT TYPE

PACKAGING CONSTRUCTION

MODEL

PAGE

Relay SPDT

Open board

NS127

2-4

Relay SPDT

Open board

NS129

2-6

Relay SPDT

Open board

NS139

2-6

Solid state switch, Norm. Open, 16 A/1 hp

Open board

NS141 Series

2-8

Relay SPDT

8-pin plug in TDR housing

DLA Series

2-3

Isolated relay SPDT

Open board

NS128

2-4

Relay SPST, Norm. Open

Open board

NS143

2-4

Relay SPDT

Open board

NS132

2-6

Solid state switch, Norm. Open, 16 A/1 hp

Open board

NS141 Series

2-8

Relay SPDT

8-pin plug in TDR housing

DLB Series

2-3

Solid state switch, Norm. Open

Open board

NS156

2-9

Relay SPST, Norm. Open

Open board

NS159

2-9

Relay SPST

Open board

NS210

2-5

Relay SPST

Open board

NS211

2-5

Relay SPDT

8-pin plug in TDR housing

05SLB Series

2-2

Solid state switch, Norm. Open

Open board

NS146

2-7

Isolated relay SPDT

Open board

NS157

2-10

Temperature Controls
DESCRIPTION

OUTPUT TYPE

Digital Temperature
Indicators

PACKAGING CONSTRUCTION

MODEL

PAGE

Chassis mount

TM110 Series

3-8

Panel mount

TM165/166

3-6

Panel mount

TM200 Series

3-9

Digital display

Digital Temperature
Controllers/Timers

Relay SPST, Norm. Open, 1 A

Panel mount

TC140 Series

3-2

Digital Temperature
Controllers

Relay SPST, Norm. Open, 1 A

Panel mount

TC142 Series

3-4

Electronic Temperature
Controllers

Relay SPST, Norm. Open, 20 A

Back panel mount

TC280 Series

3-10

vii

Dust Collector Controls
DESCRIPTION

INPUT VOLTAGE

MODEL

PAGE

1

120 VAC

DNC-T2101-010/020

4-2

3

120 VAC

DNC-T2003-A10/B10

6

10
Pulse Cleaning,
Continuous Mode or
On Demand Mode

20
32

10

Main Control Module

120 VAC

DNC-T2006-A10/B10

220 VAC

DNC-T2006-A220/B220

120 VAC

DNC-T2010-A10/B10

220 VAC

DNC-T2010-A220/B220

120 VAC

DNC-T2020-A10/B10

220 VAC

DNC-T2020-A220/B220

120 VAC

DNC-T2032-A10/B10

220 VAC

DNC-T2032-A220/B220

12 to 24 VDC

DNC-T2010-ADC

4-6

105 to 135 VAC

DNC-T2110 Series

4-8

DNC-T2610-010

10, expandable to 990

100 to 240 VAC

—

100 to 240 VAC

DNC-PS700-010

105 to 135 VAC

DNC-T2310-A10/B10

210 to 270 VAC

DNC-T2310-A220/B220

105 to 135 VAC

DNC-T2320-A10/B10

210 to 270 VAC

DNC-T2320-A220/B220

105 to 135 VAC

DNC-T2300-I/O

210 to 270 VAC

DNC-T2301-I/O

105 to 135 VAC

DNC-T2300-DSP

210 to 270 VAC

DNC-T2301-DSP

Pressure Differential Meter*

10

Pulse Cleaning, Intelligent
Dust Collector Controller
with Integral Pressure
Sensor

20

Input/Output Board for
use with Intelligent Dust
Collector Controller

—

Remote Annunciator
Panel with Intelligent Dust
Collector Controller

1

4-4

DNC-T2610-020

4-10
4-12

4-14

4-20

4-22

* May be purchased separately as an accessory to NCC Dust Collector Controls, as well as other controllers

Solid State Relays, Voltage, and Current Monitors
DESCRIPTION

Solid State Relay

3-Phase Voltage Monitor

OUTPUT
VOLTAGE

PACKAGING
CONSTRUCTION

48 to 300 VAC

1.75” x 2.25” x 1.0”
encapsulated housing

—

Single-Phase Undervoltage
Monitor

—

2 to 20 A Current Monitor

—

8-pin plug in TDR housing

OUTPUT TYPE

MODEL

Relay SPST,
Norm. Open

SNC-R2025-501/507

Relay SPST,
Norm. Closed

SNC-R2025-511/517

PAGE

5-2

Relay DPDT

PLC-240K6-44T

5-4

2” x 2” cube

Relay SPDT

VNC-120AZ-341/
VNC-240AZ-345

5-5

2.5” x 3.5” x 1.375”
encapsulated housing

Relay SPDT

IST-200T(A or Z)-141/145

5-6

Important Notice to Users
AMETEK NCC products are capable of use in a wide array of devices and in various applications. Any device or system incorporating an AMETEK NCC product should be
so designed that, in the event of failure, malfunction, or normal wear-out of the product, the device or system will become inoperative in a manner which will prevent property damage or bodily injury.
In order to keep abreast of the latest technology, AMETEK NCC reserves the right to change components and/or design of controls without notice.

PRODUCT FINDER

MAX. OUTPUTS

Shaker, Intermittent Use

Notes

1-1

AMETEK NCC Time Delay Relays are versatile, reliable and available. These affordable
solid state timers provide the MRO and OEM
markets with dependable products that stand
up to the rigorous demands of today’s marketplace. The most common standard logic
functions include the following: On Delay,
Off Delay, Interval, One Shot and Repeat
Cycle. Off-the-shelf ranges available are from
0.05 seconds to 999 hours with reliable load
switching.
AMETEK NCC Time Delay Relays offer you
a choice of sizes, shapes and terminations.
Typical configurations are open-board, socket
(8-pin, 11-pin and spade) and quick connect
terminations. These highly accurate time delay
relays are made for long-life, which is essential
for your products performance.
In addition, AMETEK NCC offers impressive
factory back-up support. Our parts inventory
and product availability is unsurpassed. With
over 250 stocking distributor outlets, serious
downtime problems can virtually be eliminated. Technical assistance for design and
engineering help is readily available through
our toll free number: 800-323-2593.

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

Electric Generator Sets
Air Compressors
Food Processing
Compressed Air Dryers
Loaders
Conveyors
Crushers and Pulverizers
Dust Collection
Home Alarm Systems
Auto Alarm Systems
Business Security Alarm Systems
Packaging Equipment
Injection Molding Equipment
Coffee Brewers
Commercial Air Conditioning
Automated Animal Feeding
Automated Fluid Spraying
Aerators
Agitators
Bag/Box Dumping Equipment
Bag Closing and Opening
Batching Systems
Compacting Equipment
Extraction Equipment
Extrusion Equipment
Feed Mill Equipment
Test Equipment
Industrial Vacuum Cleaning
Paper Shredders
Medical Equipment
Car Wash Equipment
Crane and Hoist Operations

TIME DELAY RELAYS

Common Applications:

1-2

TIME DELAY RELAYS

Multi-Time Range/Function/Input Voltage
Flatpak DMM Series

●
●
●
●
●
●

35mm DIN rail mount Flatpak enclosure
Universal input voltage
Microprocessor controlled timing circuit
Five logic modes, user selectable
Six time ranges, user selectable
Time cycles from 0.05 seconds to 999
hours
Easy 3-digit time cycle setting
±0.1% repeatability
Timing light
Superior transient protection
Ul 94VO plastic housing
File #E59090

The DMM Series offers selectable multiple
time ranges, functional logic modes and
universal input voltage range, all in one DIN
rail mount space saving Flatpak enclosure.
Programming is accomplished by using
two multi-position rotary switches. One
switch selects one of six time ranges. The
other switch selects one of five operating
logic modes. A 3-digit push-button switch
selects the amount of time required for a
timing cycle.

SPECIFICATIONS
TIME DELAY
Adjustment: 3 digit push-button switch
Range: 50 ms to 999 hours in 6 ranges
Repeatability: ±0.1% of set time or ±20 ms
whichever is greater
Accuracies: All functions ±1% of set time or ±20
ms whichever is greater
INPUT
Operating Voltage: 24 to 240 VAC ±12%, 50/60
Hz; 24 to 240 VDC ±12%, (DC unfiltered input
voltage must be full-wave rectified)
Power On Response: 50 ms max.
Power Off Reset Time: Requires power interruption of 150 ms max. (50 ms typical)
Start Switch Closure Time: 50 ms. min. to initiate timing cycle; 50 ms. min. to reset delay during
timing cycle
Power Consumption: 14 VA max. at 270 VAC,
2.5 VA max. at 24 VAC
OUTPUT
Type: Relay SPDT (1 form C)
Rating: 8 A max. resistive at 250 VAC,
5 A max. resistive at 30 VDC; 10 mA at 5 VDC
min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations

ENVIRONMENTAL
Storage Temperature: -25°C to 70°C
Operating Temperature: -25°C to 55°C
Humidity: 95% relative
MECHANICAL
Termination: 6 screw terminals; Permissible wire
size 22-12 gauge
Mounting: 35mm DIN rail mount
AMETEK NCC P/N for 3 foot section of 35 mm
rail: MRL-SOCKT-011

Start Switch

Com

Note: The DMM Series also mounts on 7.5 mm and 15 mm rails.

PROTECTION
Transient Voltage: 30 joule, 250 V metal oxide
varistor
Dielectric Breakdown: 1800 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
TIMING LIGHT LOGIC
Repeat Cycle: Full on during OFF time; Flashing
during ON time
Other Logic Modes: Flashing during timing; Full
on after time out
TIMING
Selectable Time Ranges: 0.05 to 9.99 sec.; 0.1
to 99.9 sec.; 1 to 999 sec.; 0.1 to 99.9 minutes;
1 to 999 minutes; 1 to 999 hours (times less than
50 ms are not recommended due to the response
time of the mechanical relay)
Selectable Operating Logic Modes:
Repeat Cycle (50% fixed duty cycle)
Single Shot (1 shot)
Delay On Break (D.O.B.)
Interval (Intervl)
Delay On Make (D.O.M.)
PROGRAMMING
To program the timer, remove voltage from the
unit and select the operating logic mode and the
time range; use the digital switches to select the
required time (0 to 999)

A1
(+)

15

B1

TIME SELECT

- - -

Indicator
led

0 0 0
+

+

Voltage
Source

R
A
N
G
E

9.99S
99.9S
999S

F
U
N
C
T
I
O
N

Typical
Application

+

9.99M
999M
REPEAT
1 SHOT

999H
SELECT

D.O.B.
INTRVL
D.O.M.

16

Load

18

(-)
A2

N.O.

4.45"
4.29"
NATIONAL CONTROLS
CORPORATION
WEST CHICAGO, IL. 60185

MULTIPLE FUNCTON
AND INPUT VOLTAGE
TIME DELAY RELAY

2.95"

●
●
●
●
●
●

MODEL:
DMM-9999M-24M
RANGE: .05 SEC. -999 HOUR
INPUT:
24-240VAC
DC 50 60HZ

L1

CM
A1

15

S/S
B1

(+)
24-240
VAC/DC
(-)
16

18

NC

NO

A2

L2/N

.89"

FEATURES

39.37"
(1m)
2.00"
(50.8mm)

L1

1.378"
(35mm)

1.184"
(30mm)

CM
A1

MRL-SOCKT-011

15

24-240
VAC/DC

.150"
(3.81mm)
.492"
(12.5mm)

35mm DIN Rail Dimensions

S/S
B1

(+)

(-)
.413"
(10.5mm)

16

18

NC

NO

A2

L2/N

DMM TERMINATIONS

ORDERING INFORMATION
TIME RANGE

PART NUMBER

MOUNTING TYPE

0.05 sec. to 999 hrs.

DMM-9999M-24M

35 mm DIN rail

ACCESSORY

PART NUMBER

MOUNTING TYPE

35 mm, 3 ft DIN rail

MRL-SOCKT-011

Continuous screw slots

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-3

TIME DELAY RELAYS

Multi-Time Range/Function/Input Voltage
1/16 DIN TMM Series

TIME SELECT
REPEAT
1-SHOT
D.O.B.

9 9.9 M

INTVL

999M
999H
RANGE

SELECT FUNCTION SELECT

D.O.M.

LOGIC SELECT
RANGE SELECT

FILE NO. E59090
FCC APPROVED
R

C

R

IL. 60185

N A TIO N A L C O N T R O L S
CO R P O R AT I O N

CHICAGO,

M UL TI P L E F U NCT I O N
A N D IN P U T V O L T A G E
T I ME D EL AY RE L AY

MODEL: TMM-9999M-96M
RANGE: .05 SEC.-999 HOUR
INPUT: 24-240VAC DC 50 60HZ

3.72 MAX.
(94.5mm)

.31
(7.9mm)
2.830
(71.9mm)

.66
(16.8mm)

1.755
(44.6mm)
SQUARE

1.755
(44.6mm)
SQUARE

3
6

7

8

9

8

5

9

1
4

3
2

TIME DELAY
Adjustment: 3 digit push-button switch
Range: .05 seconds to 999 hours in 6 ranges
Repeatability: ±0.1% of set time or ±20 ms
whichever is greater
Accuracies: All functions ±1% of set time or ±20
ms whichever is greater
INPUT
Operating Voltage: 24 to 240 VAC ±15%, 50/60
Hz; 24 to 240 VDC ±15%, (DC unfiltered input
voltage must be full-wave rectified)
Power On Response: 50 ms max.
Power Off Reset Time: Requires power interruption of 150 ms max. (50 ms typical)
Start Switch Closure Time: 50 ms min. to initiate timing cycle; 50 ms min. to reset delay during
timing cycle
Power Consumption: 14 VA max. at 276 VAC,
2.5 VA max. at 24 VAC

9.99S
99.9S
999S

4

SPECIFICATIONS

1.870
(47.5mm)
SQUARE

10

Note: 1) Do not apply voltage or ground to the start switch,
2) Switch leads should be shielded when running close to other
wires (Start switch suppled by customer)

"TIMING" LED
TIME SELECT

WEST

The TMM Series offers selectable multiple
time ranges, functional logic modes and
universal input voltage range, all in one
plug-in 1/16 DIN style panel mountable
package.
Programming is accomplished by using
two multi-position rotary switches. One
switch selects one of six time ranges. The
other switch selects one of five operating
logic modes. A 3-digit push-button switch
selects the amount of time required for a
timing cycle.

OUTPUT
Type: Relay DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC, 125 VDC
1/2 hp at 240 VAC; 10 mA at 5 VDC min. load
current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
ENVIRONMENTAL
Storage Temperature: -25°C to 70°C
Operating Temperature: -25°C to 55°C
Humidity: 95% relative
MECHANICAL
Termination: 11-pin plug or spade type
Mounting:
Back Panel Mounting:
Spade Base use MSO-00KUP-012
11-pin Base use MSO-0011P-012
Front Panel Mounting: 1.78” sq. opening required
Front Panel Mounting Bracket MBK-1/16D-011
11-pin Base use MSO-0011P-013
PROTECTION
Transient Voltage: 7 joule, 250 V metal oxide
varistor
Dielectric Breakdown: 1800 VAC, RMS min. at
60 Hz between input and outputs
TIMING LIGHT LOGIC
Repeat Cycle: Full On During OFF time
Flashing during ON time;
Other Logic Modes: Flashing during timing;
Full On after time out
TIMING
Selectable Time Ranges: .05 to 9.99 sec.; .1 to
99.9 sec.; 1 to 999 sec.; .1 to 99.9 minutes; 1 to
999 minutes; 1 to 999 hours (times less than 50
ms are not recommended due to the response
time of the mechanical relay)
Selectable Operating Logic Modes:
Repeat Cycle (50% fixed duty cycle)
Single Shot (1 shot)
Delay On Break (D.O.B.)
Interval (Intervl)
Delay On Make (D.O.M.)
PROGRAMMING
To program the timer, remove voltage from the
unit and select the operating logic mode and the
time range; use the digital switches to select the
required time (0 to 999)

5

100% functionally tested
1/16 DIN panel mountable enclosure
Universal input voltage
Microprocessor controlled timing circuit
Five logic modes, user selectable
Six time ranges, user selectable
Time cycles from 50 ms to 999 hours
Easy 3-digit time cycle setting
±0.1% repeatability
Timing light
Superior transient protection
Reinforced base locator pin
Flame-retardant polycarbonate housing
File #E59090

6

●
●
●
●
●
●
●
●
●
●
●
●
●
●

7

FEATURES

A

1

B

KMM-9999M-96M
PLUGS INTO
KUP-SPADE SOCKET

11

TMM-9999M-96M
PLUGS INTO
11-PIN SOCKET
5640

Start
Switch

1
4
7
A

5
8

Start
Switch

3
6
9
B

Input
24-240 VAC/DC
50/60 Hz, 14 VA
KMM PIN CONFIGURATION

4
3
2

5 6 7

8
9
10

1
11
Input
24-240 VAC/DC
50/60 Hz, 14VA
TMM PIN CONFIGURATION

ORDERING INFORMATION
TIME RANGE

PART NUMBER

MOUNTING TYPE

0.05 sec. to 999 hrs.

TMM-9999M-96M

35 mm DIN rail

0.05 sec. to 999 hrs.

KMM-9999M-96M

Spade (.187” x .020” terminal) type plug-in base

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-4

TIME DELAY RELAYS

Multi-Time Range/Function
TMM Series

3 4 7

RANGE

SELECT
SELECT

REPEAT
1-SHOT
D.O.B.
INTERVAL
D.O.M.

FUNCTION

9.99S
99.9S
999S
99.9M
999M

Logic Function

(2729-1)

3.70 Max
2.90
.19 Max

NATIONALCONTROLS
CORPORATION

WEST CHICAGO,IL.60185

MULTIPLE RANGE
SOLID STATE TIMER

MODEL: TMM-0999M-461
RANGE: .01SEC.-999MIN.

1.75

3

2

1

2.4

8

4

TIME DELAY
Adjustment: 3 digit push-button switch
Range: 50 ms to 999 minutes in 5 ranges
Repeatability: ±0.1%, ±.02 seconds over specified timing range
ACCURACIES
Delay On Make: ±1% of set time, plus fixed error
of 80 ms max. (40 ms typical including power-on
response time)
Interval, One shot: ±1% of set time, plus fixed
error of 35 ms max. (10 ms typical)
Delay On Break: ±1% of set time, plus fixed
error of 75 ms max. (10 ms typical)
Repeat Cycle, On Time: ±1% of set time, plus
fixed error of 35 ms max. (10 ms typical)
Repeat Cycle, Off Time: ±1% of set time, minus
error of 65 ms max. (10 ms typical)
INPUT
Operating Voltage: 24, 120, 240 VAC; 12, 24,
48 VDC ±10% (DC models have reverse polarity
protection. Unfiltered input voltage to them must
be full-wave rectified)

TIME SELECT

9

SPECIFICATIONS

Time Range Select
Time Select
Timing Light

10

The TMM Series offers selectable multiple
time ranges and functional logic modes all
in one plug-in package.
Programming is accomplished by using
two 5-position rotary switches. One switch
selects one of five time ranges. The other
switch selects one of five operating logic
modes. A 3-digit push-button switch selects
the amount of time required for a timing
cycle.

Power On Response: .05 sec. max.
Power Off Reset Time: .15 sec. min.
Start Switch Closure Time: .020 sec. to initiate
timing cycle; .050 sec. to reset delay during timing cycle
Power Consumption: 2 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
TIMING LIGHT LOGIC
Repeat Cycle: Flashing during ON time; Full On
during OFF time
Other Logic Modes: Flashing during timing; continuously on after time out
PROTECTION
Transient Voltage: 12, 24, 48 V timers are protected by an 8.8 joule metal oxide varistor; 120,
240 V timers are protected by a 30 joule metal
oxide varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 11-pin plug
Mounting: Socket mount, part number
MSO-0011P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C
Humidity: 95% relative
TIMING
Selectable Time Ranges: .05 to 9.99 seconds;
.1 to 99.9 seconds; 1 to 999 seconds; .1 to 99.9
minutes; 1 to 999 minutes (times less than 50 ms
are not recommended due to the response time
of the mechanical relay)
Selectable Operating Logic Modes:
Repeat Cycle (50% fixed duty cycle)
Single Shot (1 shot)
Delay On Break (D.O.B.)
Interval (Intervl)
Delay On Make (D.O.M.)
PROGRAMMING
To program the timer, remove voltage from the
unit and select the operating logic mode and the
time range; use the digital switches to select the
required time (0 to 999)

5

●
●
●
●
●

100% functionally tested
Microprocessor controlled timing circuit
Five logic modes, user selectable
Five time ranges, user selectable
Easy 3-digit time cycle setting
±0.1% repeatability
Time cycles from 50 ms to over 16
hours
Timing light
Superior transient protection
Reinforced base locator pin
Flame-retardant polycarbonate housing
File #E59090

6

●
●
●
●
●
●
●

7

FEATURES

11

Start
Switch
4

5 6 7

3

8
9

2

10
1

11

Input
Voltage
PIN CONFIGURATION
Polarity Shown is
for D.C. Models

Note: 1) Do not apply voltage or ground to the Start switch,
2) Switch leads should be shielded when running close to other
wires (Start switch suppled by customer)

ORDERING INFORMATION
TIME RANGE

12 VDC

24 VDC

48 VDC

24 VAC

120 VAC

240 VAC

.05 sec. to 999 min.

TMM-0999M-466

TMM-0999M-462

TMM-0999M-464

TMM-0999M-467

TMM-0999M-461

TMM-0999M-465

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-5

Multi-Time Range Delay On Make
A1M Series

LOGIC FUNCTION DIAGRAM
On
Off

Relay
Coil

On
Off

Timing

SPECIFICATIONS
TIME DELAY
Adjustment: 3 digit push-button switch
Range: 50 ms to 999 minutes in 5 ranges
Repeatability: ±0.1%, ±.02 seconds over specified timing range

9.99S
99.9S
999S
99.9M
999M
RANGE SELECT

A1M-0999M-461
(2729-1)

3.70 Max
2.90
.19 Max

NATIONALCONTROLS
CORPORATION

WEST CHICAGO,IL.60185

MULTIPLE RANGE
SOLID STATE TIMER

MODEL: A1M-0999M-461
RANGE: .01SEC.-999MIN.

1.75

1

8

2

Delay On Make Function

3 4 7

3

Input
Voltage

TIME SELECT

2.4

Operating Logic: Upon application of voltage to the input terminals, the time delay is
initiated. At the end of the preset time delay,
the relay coil is energized and the contacts transfer. Reset is accomplished by the
removal of input voltage.

Time Range Select
Time Select
Timing Light

6

The A1M Series is a Delay On Make time
delay relay featuring easy to program multiple time ranges and digital time selection
with extremely high accuracy and repeatability.
Programming is accomplished using a 5
position rotary switch to select one of five
time ranges. A 3-digit push-button switch
selects the amount of time delay required.

Accuracy: ±1% of set time, plus fixed error of
80 ms max. (40 ms typical including power on
response time)
INPUT
Operating Voltage: 24, 120, 240 VAC; 12, 24,
VDC ±10% (DC models have reverse polarity protection. Unfiltered input voltage to them must be
full-wave rectified)
Power On Response: .05 sec. max.
Power Off Reset Time: .15 sec. min.
Power Consumption: 2 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
TIMING LIGHT LOGIC
Repeat Cycle: Flashing during timing; continuously ON after time out
PROTECTION
Transient Voltage: 12V, 24V timers are protected
by an 8.8 joule metal oxide varistor; 120, 240 V
timers are protected by a 30 joule metal oxide
varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 8-pin plug
Mounting: Socket mount, part number
MSO-0008P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C
Humidity: 95% relative
TIMING
Selectable Time Ranges: .05 to 9.99 seconds;
.1 to 99.9 seconds; 1 to 999 seconds; .1 to 99.9
minutes; 1 to 999 minutes (times less than 50 ms
are not recommended due to the response time
of the mechanical relay)
PROGRAMMING
To program the timer, remove power from the unit
and select the time range; use the digital switches to select the required time (0 to 999)

7

●
●
●
●
●

100% functionally tested
Microprocessor controlled timing circuit
Five time ranges, user selectable
Easy 3-digit time cycle setting
±0.1% repeatability
Time cycles from 50 ms to over 16
hours
Timing light
Superior transient protection
Reinforced base locator pin
Flame-retardant polycarbonate housing
File #E59090

4

●
●
●
●
●
●

5

FEATURES

4
3

5

6
7

2

8
Input
Voltage

1

PIN CONFIGURATION
Polarity Shown is
for D.C. Models

ORDERING INFORMATION
TIME RANGE

12 VDC

24 VDC

24 VAC

120 VAC

240 VAC

.05 sec. to 999 min.

A1M-0999M-466

A1M-0999M-462

A1M-0999M-467

A1M-0999M-461

A1M-0999M-465

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-6

TIME DELAY RELAYS

Delay On Make
T1 Series

Note: 1) Remote potentiometer leads should be shielded when
running close to other wires; 2) The minimum time setting on
external resistor-adjustable time delay relays is obtained by shorting together the external resistor terminals of the relay; 3) The
maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 4) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 5)
Recommend 1/4 W minimum resistor be used.

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Relay
Coil

On
Off

Timing

Delay On Make Function

ORDERING INFORMATION
TIME RANGE

12 VDC
KNOB ADJST.
8-PIN BASE

24 VDC
KNOB ADJST.
8-PIN BASE

24 VAC
KNOB ADJST.
8-PIN BASE

120 VAC
KNOB ADJST.
8-PIN BASE

120 VAC
REMOTE POT
11-PIN BASE

240 VAC
KNOB ADJST.
8-PIN BASE

.05 to 1 sec.

—

—

—

T1K-00001-461

—

—

.1 to 10 sec.

T1K-00010-466

T1K-00010-462

T1K-00010-467

.3 to 30 sec.

T1K-00030-466

—

—

.6 to 60 sec.

T1K-00060-466

T1K-00060-462

T1K-00060-467

1.8 to 180 sec.

—

—

—

T1K-00180-461

—

—

3 to 300 sec.

—

—

—

T1K-00300-461

—

—

6 to 600 sec.

—

—

—

T1K-00600-461

—

—

36 to 3600 sec.

—

—

—

T1K-03600-461

—

—

* Optional Potentiometer: Part Number ASY-0001M-450

T1K-00010-461 T1F-00010-461* T1K-00010-465
T1K-00030-461

—

—

2.90

.85

1

8

.53

7

2.40

6

4

Operating Logic: Upon application of voltage to the input terminals, the time delay
cycle starts. At the end of the preset time
delay, the relay coil is energized and the
contacts transfer. Reset is accomplished by
the removal of input voltage.

5

TIME DELAY
Adjustment: Knob or external resistor, factory
fixed on special order (min. order required)
Range: 50 ms to 1 hour in 8 ranges
Repeatability: ±1% at constant temperature
Accuracy: Maximum time -0%, +10%;
Minimum time +0%, -50%
Reset Time: 50 ms max. (25 ms typical)
INPUT
Operating Voltage: 24, 120, 240 VAC; 12, 24
VDC ±10% (DC models have reverse polarity protection. Unfiltered input voltage to them must be
full-wave rectified)
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: 12, 24 V timers are protected
by an 8.8 joule metal oxide varistor; 120, 240 V
timers are protected by a 30 joule metal oxide
varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 8-pin or 11-pin plug
Mounting: Socket mount, 8-pin part number
MSO-0008P-012; Socket mount, 11-pin part
number MSO-0011P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Digital timing circuit
±1% repeatability
Time calibrated dial
Superior transient protection
Fiberglass reinforced circuit board
Internal components supported by
heavy-duty chassis
● Reinforced base locator pin
● Flame-retardant polycarbonate housing
●
File #E59090

2

SPECIFICATIONS

●
●
●
●
●
●
●

3

FEATURES

1.75
(3012-1)

Timing Resistor
(by Cust.)

4

5 6 7

8

3

9

2

10
1

11

Input
Voltage

4
3

5

6
7

2

8
Input
Voltage

1

PIN CONFIGURATION
Polarity Shown is
for D.C. Models

External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.

T1K-00060-461 T1F-00060-461* T1K-00060-465

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-7

TIME DELAY RELAYS

Delay On Make (Relay Output)
Q1T Series
FEATURES

SPECIFICATIONS

●
●
●
●
●
●
●
●
●

TIME DELAY
Adjustment: On-board Trimpot
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% max. (0.25% typical) at constant temperature
Accuracy: Max. time +10%, -0%;
Minimum time -30%, +0%
Reset Time: .25 seconds max., by removal of the
input voltage
INPUT
Operating Voltage: 12 VDC, 24 VAC/DC,
120 VAC/DC ±10%
Power Consumption: 3.5 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, SPDT (1 form C)
Rating: 8 A max. resistive at 250 VAC and 30
VDC; 100 mA at 5 VDC min. load current
Life:
Mechanical: 10,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Transient Voltage: 1000 P.l.V. components used
Isolation Resistance: 100 megohms min.
between terminals and case
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting; 1500 VAC, RMS, input to
output
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 70°C
Operating Temperature: -40°C to 70°C
Humidity: 95% relative

Time delays to 10 hours standard
Solid state digital timing
100% functionally tested
20:1 maximum to minimum timing ratio
Sealed SPDT output contacts
Compact size
Superior transient protection
Epoxy encapsulated
Flame-retardant and solvent-resistant
polyester thermoplastic housing
● Trimpot on-board with sealed cermet
element
●
File #E65038
Operating Logic: Upon application of voltage to the input terminals L1, L2, the time
delay is initiated. At the end of the preset
time delay, the relay coil is energized and
the contacts transfer. Reset is accomplished
by removing voltage from the input terminals.
LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Load

On
Off

Timing

Delay On Make Function

CL

.885
1.25
.25 X .032 MALE FAST-ON
TERMINALS (5 PL.)

ISOLATED
OUTPUT CONTACTS
TIME DELAY
ADJUSTMENT ACCESS
2.00 SQ.

CL N.C.

N.O.

CL
C

.170 DIA.
(3667-3)

-

INPUT
VOLTAGE

+

Polarity Shown
is for D.C. Models

ORDERING INFORMATION
TIME RANGE

12 VDC +10%

24 VAC/DC +10%

120 VAC/DC +10%

.05 to 1 sec.

—

—

Q1T-00001-341

.25 to 5 sec.

—

—

Q1T-00005-341

.5 to 10 sec.

—

Q1T-00010-347

Q1T-00010-341

3 to 60 sec.

Q1T-00060-346

—

Q1T-00060-341

15 to 300 sec.

Q1T-00300-346

—

Q1T-00300-341

30 to 600 sec.

—

—

Q1T-00600-341

180 to 3600 sec.

—

—

Q1T-03600-341

.25 to 5 hrs.

—

—

Q1T-18000-341

.5 to 10 hrs.

—

—

Q1T-36000-341

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-8

TIME DELAY RELAYS

Delay On Make (Series Load)
Q1T Series
FEATURES

SPECIFICATIONS

●
●
●
●
●
●
●
●

TIME DELAY
Adjustment: On-board Trimpot
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy: Maximum time -0%, +10%;
Minimum time -30%, +0%
INPUT
Operating Voltage: 12, 24, 120, 240 VAC/DC
±10% (on DC models, unfiltered supply voltage
must be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state normally open series load
Rating: Maximum current -1 A AC/DC (resistive
or inductive)
Life: 100,000,000 operations
PROTECTION
Transient Voltage: Metal oxide varistor (see ratings below)
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Isolation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

100% functionally tested
Solid state digital timing
20:1 maximum to minimum timing ratio
Compact size
Low cost
Superior transient protection
Epoxy encapsulated
Flame-retardant and solvent-resistant
polyester thermoplastic housing
● Trimpot on-board with sealed cermet
element
●
File #E65038
Operating Logic: Upon application of input
voltage, the time delay starts. At the end of
the time delay, the load is energized. Reset
is accomplished by removing input voltage.
Note: The load may be located on either side of the line

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Load

On
Off

Timing

Delay On Make Function

.25 X .032 MALE FAST-ON
TERMINALS (4 PL.)

.88
1.25
TIME DELAY
ADJUSTMENT
ACCESS

2.00 SQ.

CL

1

CL

3

.170
DIA.

ORDERING INFORMATION
TIME RANGE

12 VAC/DC +10%

24 VAC/DC +10%

120 VAC/DC +10%

240 VAC/DC +10%

.05 to 1 sec.

Q1T-00001-316

Q1T-00001-317

Q1T-00001-311

Q1T-00001-315

.25 to 5 sec.

Q1T-00005-316

Q1T-00005-317

Q1T-00005-311

Q1T-00005-315

.5 to 10 sec.

Q1T-00010-316

Q1T-00010-317

Q1T-00010-311

Q1T-00010-315

3 to 60 sec.

Q1T-00060-316

Q1T-00060-317

Q1T-00060-311

Q1T-00060-315

15 to 300 sec.

Q1T-00300-316

Q1T-00300-317

Q1T-00300-311

Q1T-00300-315

30 to 600 sec.

Q1T-00600-316

Q1T-00600-317

Q1T-00600-311

Q1T-00600-315

180 to 3600 sec.

Q1T-03600-316

Q1T-03600-317

—

—

Q1T-36000-316

—

—

—

.5 to 10 hrs.
TIME RANGE

Reset time, during timing

125 ms

125 ms

125 ms

10 ms

10 ms

10 ms

10 ms

10mA DC, 60 mA AC

10mA DC, 40 mA AC

10 mA

10 mA

125 ms

2 mA

4 mA

2 mA

2 mA

Voltage drop at 1 A

3.3 V max.

3.3 V max.

3.3 V max.

3.3 V max.

Power consumption

0.25 VA max.

0.25 VA max.

0.5 VA max.

0.5 VA max.

Peak 1 cycle surge

4A

4A

20 A

20 A

8.8j. MOV

8.8j. MOV

30j. MOV

30j. MOV

Protection

(3667-2)

Q1T-00480-31M

Reset time, after timeout
Max. leakage current

LOAD

24 to 240 VAC/DC +10%

24 to 480 sec.

Min. load

INPUT
VOLTAGE

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-9

Delay On Make (Series Load)
Q1F Series
FEATURES

SPECIFICATIONS

●
●
●
●
●
●
●
●

TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order requirement)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy: Maximum time ±2% at Rt = 1 megohms; Minimum time +0%, -30% at Rt = 0 ohm
INPUT
Operating Voltage: 12, 24, 120, 240 VAC/DC
±10% (on DC models, unfiltered supply voltage
must be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open series load
Rating: 1 A steady state max.
Life: 100,000,000 operations
PROTECTION
Transient Voltage: Metal oxide varistor, see ratings below
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 85°C
Humidity: 95% relative

100% functionally tested
Time delays to 10 hours standard
Solid state digital timing
20:1 maximum to minimum timing ratio
Compact size
Low cost
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038
Operating Logic: Upon application of input
voltage, the delay starts. At the end of the
time delay, the load is energized. Reset is
accomplished by removing input voltage.
Note: 1) The load may be located on either side of the line; 2)
Remote potentiometer leads should be shielded when running
close to other wires; 3) The minimum time setting on external
resistor-adjustable time delay relays is obtained by shorting
together the external resistor terminals of the relay; 4) The maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 5) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 6)
Recommend 1/4 W minimum resistor be used.

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Load

On
Off

Timing

.25 X .032 MALE FAST-ON
TERMINALS (4 PL.)

.88
1.25
2.00 SQ.
Rt

5

Delay On Make Function

CL

ORDERING INFORMATION
TIME RANGE

24 VAC/DC +10%

120 VAC/DC +10%

240 VAC/DC +10%

.05 to 1 sec.

Q1F-00001-316

Q1F-00001-317

Q1F-00001-311

—

Q1F-00005-316

Q1F-00005-317

Q1F-00005-311

Q1F-00005-315

.5 to 10 sec.

Q1F-00010-316

Q1F-00010-317

Q1F-00010-311

—

3 to 60 sec.

Q1F-00060-316

Q1F-00060-317

Q1F-00060-311

—

15 to 300 sec.

Q1F-00300-316

Q1F-00300-317

Q1F-00300-311

Q1F-00300-315

30 to 600 sec.

—

—

Q1F-00600-311

—

180 to 3600 sec.

Q1F-03600-316

Q1F-03600-317

Q1F-03600-311

Q1F-03600-315

.25 to 5 hrs.

Q1F-18000-316

Q1F-18000-317

Q1F-18000-311

—

Q1F-36000-316

—

Q1F-36000-311

Q1F-36000-315

125 ms

125 ms

125 ms

125 ms

Reset time, during timing
Reset time, after timeout
Min. load
Max. leakage current
Voltage drop at 1 A
Power consumption, during
timing
Power consumption, after
timeout
Peak 1 cycle surge
Protection

10 ms

10 ms

10 ms

10 ms

10mA DC, 60 mA AC

10mA DC, 40 mA AC

10 mA

10 mA

2 mA

4 mA

2 mA

2 mA

3.3 V max.

3.3 V max.

3.3 V max.

3.3 V max.

0.25 VA max.

0.25 VA max.

0.5 VA max.

0.5 VA max.

3.0 VA max.

3.0 VA max.

3.0 VA max.

3.0 VA max.

20 A

20 A

20 A

20 A

8.8j. MOV

8.8j. MOV

30j. MOV

30j. MOV

Optional Potentiometer: Part Number ASY-0001M-450

3

1

12 VAC/DC +10%

.25 to 5 sec.

.5 to 10 hrs.

4
CL

INPUT
VOLTAGE

.170
DIA.

LOAD

(3667-1)

External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-10

TIME DELAY RELAYS

Delay On Make (Alarm Output)
Q1F Alarm Series
FEATURES

SPECIFICATIONS

● 100% functionally tested
● Time delays to 10 hours standard
● Loud audio alarm for use in noisy envi-

TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order requirement)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy: Max. +0%, -30% at Rt = 0 ohm
Reset Time:
During Timing: 300 ms
After Timeout: 150 ms
INPUT
Operating Voltage: 120 or 240 VAC ±10%
Frequency: 50/60 Hz
OUTPUT
Type: Solid state Piezo Audio Alarm
Alarm Frequency: 3.15 kHz ±0.5 kHz
Sound Pressure Level: 76 dB at 1 meter
Life: 10,000,000 operations
PROTECTION
Transient Voltage: Metal oxide varistor
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 75°C
Operating Temperature: 0°C to 65°C
Humidity: 95% relative

ronments
Solid state digital timing
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E165149

●
●
●
●
●
●

The Q1F Delay to Alarm Cube Timer is
intended for use as a Delay On Make audible alarm.
Operating Logic: Upon application of the
input voltage, the time delay starts. At the
end of the preset time delay the audible
alarm is activated. Reset is accomplished
by removing input voltage.
Note: 1) Remote potentiometer leads should be shielded when
running close to other wires; 2) The minimum time setting on
external resistor-adjustable time delay relays is obtained by shorting together the external resistor terminals of the relay; 3) The
maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 4) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 5)
Recommend 1/4 W minimum resistor be used.

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Audio
Alarm

On
Off

.25 X .032 MALE FAST-ON
TERMINALS (5 PL.)

.88
1.25

2.00 SQ.

Input
Voltage

CL
CL

.170
DIA.

Timing

Rt

Delay On Make Function

ORDERING INFORMATION
TIME RANGE

120 VAC 50/60 Hz

240 VAC 50/60 Hz

.05 to 1 sec.

—

Q1F-00001-3A5

.25 to 5 sec.

—

Q1F-00005-3A5

.5 to 10 sec.

—

Q1F-00010-3A5

3 to 60 sec.

Q1F-00060-3A1

Q1F-00060-3A5

15 to 300 sec.

—

Q1F-00300-3A5

30 to 600 sec.

—

Q1F-00600-3A5

180 to 3600 sec.

Q1F-03600-3A1

Q1F-03600-3A5

.25 to 5 hrs.

Q1F-18000-3A1

Q1F-18000-3A5

Q1F-36000-3A1

Q1F-36000-3A5

.5 to 10 hrs.
Optional Potentiometer: Part Number ASY-0001M-450

External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-11

Delay on Make (Series Load)
Q1D Series
FEATURES

SPECIFICATIONS

● 100% functionally tested
● Time delay from 1 to 1023 seconds in 1

TIME DELAY
Adjustment: 10 position DIP switch
Range: 1 to 1023 seconds in one second increments. Zero time setting is undefined.
Repeatability: ±0.5% (0.25% typical) at constant
temperature
Accuracy: ±10% of set time +0.25 second
INPUT
Operating Voltage: 24 to 240 VAC/DC ±10% (on
voltage must be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open series load
Rating: 1 A steady state max.
Life: 100,000,000 operations
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

second increments

● Universal input voltage 24 to 240

VAC/DC
Solid state digital timing
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038

●
●
●
●
●

Allows user to accurately set delay times up
to 1023 seconds without time consuming
trial and error adjustments.
Operating Logic: Upon application of input
voltage, the delay starts. At the end of the
time delay, the load is energized. Reset is
accomplished by removing input voltage.
Set the delay time by switching the appropriate combination of time values to the ON
position.
Note: The load may be located on either side of the line

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Load

On
Off

Timing

.885
1.25 MAX
.250 X .032 MALE
SPADE TERMINAL
(2 PL.)

10 POSITION SWITCH
TIME DELAY SELECT
2.00 SQ.
1
2
4
8
16
32
64
128
256
512

Delay On Make Function

.170
DIA.

ON

ORDERING INFORMATION
TIME RANGE
1 to 1023 sec.

OFF

24 to 240 VAC/DC +10%
Q1D-01024-31M

Reset time, during timing

125 ms

Reset time, after timeout

10 ms

Min. load
Max. leakage current
Voltage drop at 1 A

2 mA
3.3 V max.
0.25 VA max.

Power consumption, after timeout

3.3 VA max.

Protection

C
L

10mA or 1 VA, whichever is greater

Power consumption, during timing

Peak 1 cycle surge

CL

INPUT
VOLTAGE

LOAD

7865/7/97

20 A
30j. MOV

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-12

TIME DELAY RELAYS

Delay On Make
K1 Series

TIME DELAY
Adjustment: Knob or external resistor, factory
fixed on special order (min. order required)
Range: 100 ms to 5 minutes in 5 ranges
Repeatability: ±.5% at constant temperature and
reset time, but not less than 16 ms.
Accuracy: Maximum time +(10%, +20 ms)/-0%;
Minimum time -50%/+(0%, +20 ms)
Reset Time: 80 ms max.
INPUT
Operating Voltage: 24, 120 VAC; 12, 24 VDC
±10% (DC models have reverse polarity protection. Unfiltered input voltage to them must be fullwave rectified)
Power Consumption: 3 VA max.
Frequency: 50/60 Hz (AC units)
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 1,000,000 operations
Full Load: 150,000 operations
PROTECTION
Transient Voltage: 12 and 24 V timers are protected by a 1 joule metal oxide varistor; 120 V
and 240 V timers are protected by a 5 joule metal
oxide varistor.
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: Spade (.187” x .020” terminal) type
plug-in base
Mounting: Socket mount, part number
MSO-00KUP-012, or flange mount
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

●
●
●
●
●
●
●
●
●

during timing
Digital timing circuit
Time delays to 5 minutes
Low cost
Compact size
Spade type base
Wide operating temperature range
Fiberglass reinforced circuit board
Polycarbonate, 94V-2 housing material
File #E59090

Operating Logic: Upon application of voltage to the input terminals, the time delay
cycle starts. At the end of the preset time
delay, the relay coil is energized and the
contacts transfer. Reset is accomplished by
the removal of input voltage.
Note: 1) Remote potentiometer leads should be shielded when
running close to other wires; 2) The minimum time setting on
external resistor-adjustable time delay relays is obtained by shorting together the external resistor terminals of the relay; 3) The
maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 4) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 5)
Recommend 1/4 W minimum resistor be used.

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Relay
Coil

On
Off

Timing

Delay On Make Function

Case 5

1.835

.25

2.50
1.90
.437
.312

SPECIFICATIONS

● 100% functionally tested
● No false contact transfer when reset

.625

FEATURES

Case 7

.156
2 Pl.
(3021-3)

Timing Resistor
(By Cust.)

1
4
7
A

2
5

3
6
9
B

Input
Voltage
Polarity Shown is
for D.C. Models

Case 6

.70
Max.

2.125

.25

12 VDC
KNOB ADJST
CASE 6

12 VDC
REMOTE POT
CASE 5

24 VDC
KNOB ADJST
CASE 6

24 VDC
REMOTE POT
CASE 5

.1 to 10 sec.

K1K-00010-666

K1K-00010-566

K1K-00010-662

—

.3 to 30 sec.

K1K-00030-666

K1K-00030-566

—

—

.6 to 60 sec.

K1K-00060-666

K1K-00060-566

K1K-00060-662

K1F-00060-562

3 to 300 sec.

K1K-00300-666

—

K1K-00300-662

—

24 VAC
KNOB ADJST
CASE 6

24 VAC
REMOTE POT
CASE 5

120 VAC
KNOB ADJST
CASE 6

120 VAC
REMOTE POT
CASE 7

TIME RANGE

TIME RANGE

1.406

ORDERING INFORMATION

1.531

120 VAC
REMOTE POT
CASE 5

.1 to 5 sec.

—

—

—

K1K-00005-761

—

.1 to 10 sec.

K1K-00010-667

K1K-00010-567

K1K-00010-661

—

K1F-00010-561

.3 to 30 sec.

—

—

K1K-00030-661

K1K-00030-761

—

.6 to 60 sec.

—

—

K1K-00060-661

—

K1F-00060-561

3 to 300 sec.

K1K-00300-667

—

K1K-00300-661

—

—

Optional Potentiometer: Part Number ASY-0001M-450

3
6
9

1
4
7
A

B
Input
Voltage

Polarity Shown is
for D.C. Models

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-13

Delay On Make
Z1 Series

SPECIFICATIONS

●
●
●
●
●
●
●
●

TIME DELAY
Adjustment: Trimpot, factory fixed on
special order (min. order required)
Range: 100 ms to 5 minutes in 4 ranges
(other ranges available on special order)
Repeatability: ±1% at constant temperature
Accuracy: Maximum -0%, +10%; Minimum time
+0%, -50%
Reset Time: 50 ms max. (25 ms typical)
INPUT
Operating Voltage: 24, 120 VAC; 24 VDC ±10%
(DC models have reverse polarity protection;
unfiltered input voltage to them must be full-wave
rectified)
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: 24 V timers are protected by
an 8.8 joule metal oxide varistor; 120 V timers are
protected by a 30 joule metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: .25” standoffs, #6 screw
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Digital timing circuit
Time delays to 5 minutes
±1% repeatability
Fast-on terminals for quick installation
Low cost, open board construction
Fiberglass reinforced circuit board
File #E59090

Operating Logic: Upon application of voltage to the input terminals, the time delay
cycle starts. At the end of the preset time
delay, the relay coil is energized and the
contacts transfer. Reset is accomplished by
the removal of input voltage.
LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Relay
Coil

On
Off

Timing

Delay On Make Function

.25 X .032 Male
Fast-on (16 Pl.)
2.125
1.50

.313
Typ.

NC

NC

NO

NO

C

C

3.00
3.625

FEATURES

INC

L1

L2

Input
.141 Dia.
Voltage
(4 Holes)
Polarity is shown
for DC models
Time Adjust

.27
1.875

(3021-1)

ORDERING INFORMATION
TIME RANGE

24 VAC

120 VAC

.1 to 1 sec.

—

Z1T-00010-061

.6 to 60 sec.

Z1T-00060-067

Z1T-00060-061

1.8 to 180 sec.

Z1T-00180-067

—

3 to 300 sec.

Z1T-00300-067

Z1T-00300-061

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-14

TIME DELAY RELAYS

Single Shot
T2 Series

Input
Voltage

On
Off

Start
Switch

Closed
Open

Relay
Coil

On
Off

Timing

Single Shot Function

1.75

9

2.4

8

5

LOGIC FUNCTION DIAGRAM

.53

6
1

10

Note: 1) Do not apply voltage or ground to the Start switch, 2)
Switch leads should be shielded when running close to other wires
(Start switch supplied by customer)

2.90

.85

7

Operating Logic: Voltage is applied to the
timer at all times. Upon a momentary or
maintained closure of a normally open isolated start switch, the output relay coil is
energized and the time delay starts. At the
end of the preset time delay, the relay coil
is de-energized and the timer is ready for a
new cycle.

2

TIME DELAY
Adjustment: Knob, factory fixed on special order
(min. order required)
Range: 100 ms to 1 hour in 7 ranges
Repeatability: ±1% at constant temperature
Accuracy: Maximum time -0%, +10%;
Minimum time +0%, - 50%
Reset Time: 400 ms max.
INPUT
Operating Voltage: 24, 120 VAC; 12, 24 VDC
±10% (DC models have reverse polarity protection; unfiltered input voltage to them must be fullwave rectified)
Start Switch Closure Time: 20 ms min.
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, SPDT (1 form C) or DPDT;
(2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: 12 and 24 V timers are protected by an 8.8 joule metal oxide varistor; 120 V
timers are protected by a 30 joule metal oxide
varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 8-pin or 11-pin plug
Mounting: Socket mount, 8-pin part number
MSO-0008P-012; socket mount, 11-pin part
number MSO-0011P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Digital timing circuit
Time delays to 1 hour
±1% repeatability
Superior transient protection
Fiberglass reinforced circuit board
Internal components supported by
heavy-duty chassis
● Reinforced locator pin
● Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E59090

3

SPECIFICATIONS

●
●
●
●
●
●
●

4

FEATURES

11

Start Switch
(by Cust.)

4

5 6 7

3

8
9

2

10
1
11
Input
Voltage

PIN CONFIGURATION
Start Switch
(by Cust.)

4
3

5

6
7

2

8
Input
Voltage

1

ORDERING INFORMATION
12 VDC
DPDT RELAY
11-PIN BASE

24 VDC
DPDT RELAY
11-PIN BASE

24 VAC
DPDT RELAY
11-PIN BASE

120 VAC
SPDT RELAY
8-PIN BASE

120 VAC
DPDT RELAY
11-PIN BASE

.1 to 10 sec.

T2K-00010-466

T2K-00010-462

T2K-00010-467

T2K-00010-441

T2K-00010-461

.3 to 30 sec.

—

—

—

—

T2K-00030-461

TIME RANGE

.6 to 60 sec.

T2K-00060-466

T2K-00060-462

T2K-00060-467

T2K-00060-441

T2K-00060-461

1.8 to 180 sec.

—

—

—

—

T2K-00180-461

3 to 300 sec.

—

—

—

—

T2K-00300-461

6 to 600 sec.

—

—

—

—

T2K-00600-461

36 to 3600 sec.

—

—

—

—

T2K-03600-461

PIN CONFIGURATION
Polarity Shown is
for D.C. Models

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-15

TIME DELAY RELAYS

Single Shot
Q2T Series
FEATURES

LOGIC FUNCTION DIAGRAM

●
●
●
●
●
●
●
●
●

100% functionally tested
Solid state digital timing
Time delays to 5 hours standard
20:1 maximum to minimum timing ratio
Cost efficient
Compact size
Superior transient protection
Epoxy encapsulated
Flame-retardant and solvent-resistant
polyester thermoplastic housing
● Trimpot on-board with sealed cermet
element
●
File #E65038
Operating Logic: Power is applied to the
timer at all times. Upon a momentary or
maintained closure of a normally open isolated start switch, the output is energized
and the time delay starts. At the end of the
preset time delay, the output is de-energized and the unit is ready for a new cycle.
Note: 1) Do not apply voltage or ground to the start switch; 2)
Switch leads should be shielded when running close to other
wires. (Start switch supplied by customer.)

120 VAC +10%

.05 to 1 sec.

Q2T-00001-321

.25 to 5 sec.

Q2T-00005-321

.5 to 10 sec.

Q2T-00010-321

3 to 60 sec.

Q2T-00060-321

15 to 300 sec.

Q2T-00300-321

30 to 600 sec.

Q2T-00600-321

180 to 3600 sec.

Q2T-03600-321

.25 to 5 hrs.

Q2T-18000-321

Trigger time (start switch
closure)

20 ms

Reset time

300 ms

Min. load
Max. leakage current

Closed
Open

Load

On
Off

Timing

Single Shot Function

SPECIFICATIONS
TIME DELAY
Adjustment: On-board Trimpot
Range: 50 ms to 5 hours in 8 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy: Maximum time +10%, -0%;
Minimum time -30%. +0%
INPUT
Operating Voltage: 120 VAC ±10%
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open
Rating: 1 A resistive or inductive
Life: 100,000,000 cycles
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

.25 X .032 MALE FAST-ON
TERMINALS (5 PL.)

.88
1.25

TIME DELAY
ADJUSTMENT ACCESS
2.00 SQ.

CL
CL

START
SWITCH

1

2

3

.170
DIA.

LOAD
(3667-4)

INPUT
VOLTAGE

Polarity Shown is
for D.C. Models

2 mA
200 uA

Voltage drop at 1 A

3.3 V max.

Power consumption

4.3 VA max.

Peak 1 cycle surge

20 A

Protection

Start
Switch

7

TIME RANGE

On
Off

6

ORDERING INFORMATION

Input
Voltage

30j. MOV

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-16

TIME DELAY RELAYS

Single Shot
Q2F Series
FEATURES

LOGIC FUNCTION DIAGRAM

●
●
●
●
●
●
●
●

100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038
Operating Logic: Input voltage is applied to
the timer at all times. Upon a momentary or
maintained closure of a normally open isolated start switch, the load energizes and
the time delay starts. At the end of the preset time delay, the load de-energizes and
the timer is ready for a new timing cycle.
(Start switch supplied by customer)
Note: 1) Remote start switch leads should be shielded when running close to other wires; 2) Remote potentiometer leads should
be shielded when running close to other wires; 3) The minimum
time setting on external resistor-adjustable time delay relays is
obtained by shorting together the external resistor terminals of
the relay; 4) The maximum time setting within tolerance limits is
obtained by using a 1 megohm resistor; 5) Timing values between
the minimum and maximum limits are linear with resistance within
10%; 6) Recommend 1/4 W minimum resistor be used.

ORDERING INFORMATION

On
Off

Start
Switch

Closed
Open

Load

On
Off

Timing

Single Shot Function

SPECIFICATIONS
TIME DELAY
Adjustment: External resistor factory fixed on
special order (min. order requirement)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohms
Minimum time +0%, -30% at Rt = 0 ohm
INPUT
Operating Voltage: 120, 240 VAC; 12 VDC; 24
VAC/DC ±10% (DC models have reverse polarity
protection; unfiltered input voltage to them must
be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open
Rating: 1 A steady state
Life: 100,000,000 operations
PROTECTION
Transient Voltage: Metal oxide varistor, see ratings below
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting

.88
1.25

2.00 SQ.
Rt

24 VAC/DC +10%

120 VAC +10%

240 VAC +10%

5

Q2F-00001-326

Q2F-00001-327

Q2F-00001-321

Q2F-00001-325

Q2F-00005-326

Q2F-00005-327

Q2F-00005-321

Q2F-00005-325

.5 to 10 sec.

Q2F-00010-326

Q2F-00010-327

Q2F-00010-321

Q2F-00010-325

3 to 60 sec.

Q2F-00060-326

Q2F-00060-327

Q2F-00060-321

Q2F-00060-325

15 to 300 sec.

Q2F-00300-326

Q2F-00300-327

Q2F-00300-321

—

30 to 600 sec.

Q2F-00600-326

Q2F-00600-327

Q2F-00600-321

Q2F-00600-325

180 to 3600 sec.

Q2F-03600-326

Q2F-03600-327

Q2F-03600-321

—

.25 to 5 hrs.

Q2F-18000-326

Q2F-18000-327

Q2F-18000-321

Q2F-18000-325

.5 to 10 hrs.

Q2F-36000-326

—

Q2F-36000-321

—

Trigger time (start switch closure)

20 ms

20 ms

20 ms

20 ms

Reset time

200 ms

200 ms

300 ms

300 ms

Min. load

5 mA

5 mA

2 mA

2 mA

Max. leakage current

10 uA

10 uA

200 uA

300 uA

Voltage drop at 1 A

2.1 V

3.2 V

3.3 V

3.3 V

Power consumption

2.6 W

3.7 VA max.

4.3 VA max.

5.8 VA max.

4A

4A

20 A

20 A

8.8j. MOV

8.8j. MOV

30j. MOV

30j. MOV

Optional Potentiometer: Part Number ASY-0001M-450
Consult factory for any special requirements not listed in catalog (minimum order requirement may apply).

4
CL
CL

7

.05 to 1 sec.

Protection

.25 X .032 MALE FAST-ON
TERMINALS (7 PL.)

12 VDC +10%

.25 to 5 sec.

Peak 1 cycle surge

Insulation Resistance: 100 megohms
min. between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on
terminals
Mounting: Surface mount with one #8
screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

6

TIME RANGE

Input
Voltage

START
SWITCH

1

2

3

.170
DIA.

LOAD
(3667-4)

INPUT
VOLTAGE

Polarity Shown is
for D.C. Models
External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-17

Single Shot
K2 Series

SPECIFICATIONS

●
●
●
●
●
●
●
●
●

TIME DELAY
Adjustment: Knob, factory fixed on special
order (min. order required)
Range: 100 ms to 10 sec.
Repeatability: ±3% at constant temperature
Accuracy:
Maximum time +10%/-0%
Minimum time +0%/-50%
Reset Time: 200 ms max.
INPUT
Operating Voltage: 120 V AC ±10%
Start Switch Closure Time: 50 ms min.
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC 100 mA at
5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: Timers are protected by a 5
joule metal oxide varistor
Dielectric Breakdown: 1500 VAC RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: Spade (.187” x .020” terminal) type
plug-in base
Mounting: Socket mount, part number
MS0-00KUP-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Time delays to 10 seconds
Low cost
Compact size
Spade type base
Wide operating temperature range
Fiberglass reinforced circuit board
Polycarbonate, 94V-2 housing material
File #E59090

Operating Logic: Voltage is applied to the
timer at all times. Upon a momentary or
maintained closure of a normally open isolated start switch, the output relay coil is
energized and the time delay starts. At the
end of the preset time delay, the relay coil
is de-energized and the timer is ready for a
new cycle.
Note: 1) Do not apply voltage or ground to the Start switch;
2) Switch leads should be shielded when running close to other
wires (Start switch supplied by customer)

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Start
Switch

Closed
Open

Relay
Coil

On
Off

Timing

Single Shot Function

Case 6

.70
Max.

2.125

.25

(3021-4)

1.406

FEATURES

1.531

Start Switch
(By Cust.)

1
4
7
A

+

5
8

3
6
9
B

-

Input
Voltage
Polarity Shown is
for D.C. Models

ORDERING INFORMATION
TIME RANGE
.1 to 10 sec.

120 VAC
K2K-00010-661

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-18

TIME DELAY RELAYS

Multi-Range Delay On Break (Retriggerable)
T3M Series

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Closed
Open

120V
0V

Relay
Coil

On
Off

Start Switch Version
Control Voltage Version

Timing

Delay On Break Function

3 4 7
9.99S
99.9S
999S
99.9M
999M
RANGE SELECT

T3M-0999M-461
(2729-1)

3.70 Max
2.90
.19 Max

NATIONALCONTROLS
CORPORATION

WEST CHICAGO,IL.60185

MULTIPLE RANGE
SOLID STATE TIMER

MODEL: T3M-0999M-461
RANGE: .01SEC.-999MIN.

1.75

9

2.4

8

5
1

10

Operating Logic: Voltage is continuously
applied to the timer. Depending upon the
model, either a switch closure or application of control voltage causes the relay coil
to be energized and remain so as long as
the switch is held closed or control voltage
is applied. Opening the switch or removing
the control voltage starts the timing cycle.
At the end of the preset time delay, the relay
coil de-energizes and the timer is ready for
a new timing cycle. If the start switch is reclosed or control voltage is re-applied during timing, the timer will reset and will not
start timing until the start switch is opened
or control voltage is removed. Control leads
should be shielded when close to other
leads.

TIME SELECT

6

The T3M Series is a Delay On Break time
delay relay featuring easy to program multiple time ranges and digital time selection
with extremely high accuracy and repeatability. Programming is accomplished using
a 5 position rotary switch to select one
of five time ranges. A 3-digit push-button
switch selects the amount of time delay
required.

Time Range Select
Time Select
Timing Light

7

●
●
●
●
●

2

TIME DELAY
Adjustment: 3 digit push-button switch
Range: 50 ms to 999 minutes in 5 ranges
Repeatability: ±0.1%, ±.02 seconds over specified timing range
Accuracy: ±1% of set time, plus fixed error of 75
ms max. (10 ms typical)
Power On Response Time: 50 ms max.
Power Off Reset Time: Requires power interruption of .15 seconds min.
Start Switch Closure Time: 20 ms to initiate
timing cycle; 50 ms to reset delay during timing
cycle
INPUT
Operating Voltage: 24, 120 VAC; 12, 24 VDC
±10% (DC models have reverse polarity protection; unfiltered input voltage to them must be fullwave rectified)
Power Consumption: 2 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: 12 and 24 V timers are protected by an 8.8 joule metal oxide varistor; 120
V timers are protected by a 30 joule metal oxide
varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
Timing Light Logic: Flashing during timing; Full
ON after time out
MECHANICAL
Termination: 11-pin plug
Mounting: Socket mount, part number
MSO-0011P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C
Humidity: 95% relative
TIMING
Selectable Time Ranges: .05 to 9.99 seconds;
.1 to 99.9 seconds; 1 to 999 seconds; .1 to 99.9
minutes; 1 to 999 minutes; (times less than 50 ms
are not recommended due to the response time
of the mechanical relay)

100% functionally tested
Microprocessor controlled timing circuit
Five time ranges, user selectable
Easy 3-digit time cycle setting
±0.1% repeatability
Time cycles from 50 ms to over 16
hours
Timing light
Superior transient protection
Reinforced base locator pin
Flame-retardant polycarbonate housing
File #E59090

3

SPECIFICATIONS

●
●
●
●
●
●

4

FEATURES

11

Start
Switch
OR
120 VAC
Control
Voltage *
4

5 6 7

3

8
9

2

+

10
1
11
Input
Voltage

-

PIN CONFIGURATION
Polarity Shown is
for D.C. Models

ORDERING INFORMATION
START OF TIMING METHOD
Start Switch
Control Voltage

12 VDC

24 VDC

24 VAC

120 VAC

T3M-0999M-466

T3M-0999M-462

T3M-0999M-467

T3M-0999M-461

—

—

—

T3M-0999M-461V

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-19

Delay On Break (Retriggerable)
T3 Series
FEATURES

SPECIFICATIONS

●
●
●
●
●

TIME DELAY

On
Off

MECHANICAL

Start Switch
(by Cust.)

4

5 6 7

3

8
9
10

1
11
Input
Voltage
PIN CONFIGURATION
Start Switch
(by Cust.)

ENVIRONMENTAL

Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

ORDERING INFORMATION
24 VDC
DPDT RELAY
11-PIN BASE

24 VAC
DPDT RELAY
11-PIN BASE

120 VAC
SPDT RELAY
8-PIN BASE

120 VAC
DPDT RELAY
11-PIN BASE

.05 to 5 sec.

—

—

—

—

T3K-00005-461

.1 to 10 sec.

T3K-00010-466

T3K-00010-462

T3K-00010-467

T3K-00010-441

T3K-00010-461

.3 to 30 sec.

—

—

—

—

T3K-00030-461

.6 to 60 sec.

T3K-00060-466

T3K-00060-462

T3K-00060-467

T3K-00060-441

T3K-00060-461

1.8 to 180 sec.

—

—

—

—

T3K-00180-461

3 to 300 sec.

—

—

—

—

T3K-00300-461

6 to 600 sec.

—

—

—

—

T3K-00600-461

36 to 3600 sec.

T3K-03600-466

T3K-03600-462

T3K-03600-467

—

T3K-03600-461

TIME RANGE

4
3

5

6
7

2

12 VDC
DPDT RELAY
11-PIN BASE

2.4

8

9
11

2

Termination: 8-pin or 11-pin plug
Mounting: Socket mount, 8-pin part number MSO-0008P-012; socket mount, 11-pin
part number MSO-0011P-012

Delay On Break Function

1

10

2

Closed
Open
Timing

Relay
Coil

1.75

Transient Voltage: 12 and 24 V timers are
protected by an 8.8 joule metal oxide varistor; 120 V timers are protected by a 30 joule
metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS
min. at 60 Hz between input and outputs
and between outputs

On
Off

.53

3

Start
Switch

Type: Relay contacts, SPDT (1 form C) or
DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100
mA at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations

2.90

.85

PROTECTION

LOGIC FUNCTION DIAGRAM
Input
Voltage

OUTPUT

4

Note: 1) Do not apply voltage or ground to the start switch; 2)
Switch leads should be shielded when running close to other
wires; 3) If the start switch is reclosed during timing, the timer will
reset and will not start timing until Start switch is opened.

Operating Voltage: 24, 120 VAC; 12, 24
VDC ±10% (DC models have reverse polarity protection. Unfiltered input voltage to
them must be full-wave rectified)
Power Consumption: 3 VA max.
Frequency: 50/60 Hz

5

Operating Logic: Voltage is applied to the
timer at all times. Upon a closure of a normally open isolated start switch, the output
relay is activated and remains so as long as
the switch is kept closed. When the start
switch is opened, timing starts. At the end
of the preset time delay, the output relay is
deactivated and the timer is ready for a new
cycle.

INPUT

6

●
●
●

Adjustment: Knob, factory fixed on special
order (min. order required)
Range: 50 ms to 1 hour in 8 ranges
Repeatability: ±1% at constant temperature
Accuracy:
Maximum time -0%, +10%
Minimum time +0%, -50%
Reset Time: 400 ms max.
Start Switch Closure Time: 20 ms to initiate timing; 50 ms to reset delay during timing

7

●
●
●

100% functionally tested
Digital timing circuit
Time delays to 1 hour
±1% repeatability
No false contact transfer when reset
during timing
Superior transient protection
Fiberglass reinforced circuit board
Internal components supported by
heavy-duty chassis
Reinforced locator pin
Flame-retardant polycarbonate housing
File #E59090

8
Input
Voltage

1

PIN CONFIGURATION
Polarity Shown is
for D.C. Models

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-20

TIME DELAY RELAYS

Delay On Break (Retriggerable)
Q3T Series

TIME DELAY
Adjustment: On-board Trimpot
Range: 50 ms to 1 hour in 7 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy: Maximum time +10%, -0%;
Minimum time -30%, +0%
Reset Time: .5 seconds max. by removal of the
input voltage
INPUT
Operating Voltage: 120/240 VAC ±10%
Frequency: 50/60 Hz
OUTPUT
Type: Solid state normally open
Rating: 1 A resistive or inductive
Life: 100,000,000 cycles
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Isolation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

100% functionally tested
Solid state digital timing
Time delays to 1 hour standard
20:1 maximum to minimum timing ratio
Cost efficient
Compact size
Superior transient protection
Epoxy encapsulated
Flame-retardant and solvent-resistant
polyester thermoplastic housing
● Trimpot on-board with sealed cermet
element
●
File #E65038
Operating Logic: Input voltage is applied to
the timer at all times. Upon closure of a normally open isolated start switch, the load is
energized and remains in this state as long
as the switch is kept closed. When the start
switch is opened, timing starts. At the end
of the preset time delay the output de-energizes and the unit is ready for a new cycle.
(Start switch supplied by customer.)
Note: 1) Do not apply voltage or ground to the start switch;
2) Switch leads should be shielded when running close to other
wires; 3) If the start switch is re-closed during timing the timer will
reset and will not start timing until the start switch is opened.

LOGIC FUNCTION DIAGRAM
Input
Voltage

.25 X .032 MALE FAST-ON
TERMINALS (5 PL.)

.88
1.25

TIME DELAY
ADJUSTMENT ACCESS

2.00 SQ.

CL
CL

7

SPECIFICATIONS

●
●
●
●
●
●
●
●
●

6

FEATURES

START
SWITCH

1

2

3

On
Off

.170
DIA.

LOAD

Start
Switch

Closed
Open

(3667-4)

Timing

Load

On
Off
Delay On Break Function

INPUT
VOLTAGE

Polarity Shown is
for D.C. Models

ORDERING INFORMATION
TIME RANGE

120 VAC +10%

240 VAC +10%

.05 to 1 sec.

Q3T-00001-321

—

.25 to 5 sec.

Q3T-00005-321

—

.5 to 10 sec.

Q3T-00010-321

—

3 to 60 sec.

Q3T-00060-321

—

15 to 300 sec.

Q3T-00300-321

Q3T-00300-325

30 to 600 sec.

Q3T-00600-321

—

180 to 3600 sec.

Q3T-03600-321

—

Trigger time (start switch closure)

20 ms

Reset time

500 ms

Min. load
Max. leakage current

2 mA
200 uA

Voltage drop at 1 A

3.3 V max.

Power consumption

4.3 VA max.

Peak 1 cycle surge

20 A

Protection

30j. MOV

Consult factory for any special
requirements not listed in catalog
(minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-21

TIME DELAY RELAYS

Delay On Break (Retriggerable)
Q3F Series
FEATURES

LOGIC FUNCTION DIAGRAM

●
●
●
●
●
●
●
●

100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038
Operating Logic: Input voltage is applied
to the timer at all times. Upon closure of a
normally open isolated start switch, the load
energizes and remains energized as long as
the switch is closed. When the start switch
opens, the timing cycle starts. At the end
of the preset time delay, the load de-energizes and the timer is ready for a new timing
cycle. (Start switch supplied by customer.)
Note: 1) Do not apply voltage or ground to start switch; 2) remote
start switch leads should be shielded when running close to
other wires; 3) If the start switch is re-closed during timing, the
delay will reset and will not start timing until the start switch
is opened; 4) Remote potentiometer leads should be shielded
when running close to other wires; 5) The minimum time setting
on external resistor-adjustable time delay relays is obtained by
shorting together the external resistor terminals of the relay; 6)
The maximum time setting within tolerance limits is obtained by
using a 1 megohm resistor; 7) Timing values between the minimum and maximum limits are linear with resistance within 10%;
8) Recommend 1/4 W minimum resistor be used.

Closed
Open
Timing

Load

On
Off
Delay On Break Function

SPECIFICATIONS
TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order required)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohm
Minimum time +0%-30% at Rt = 0 ohm
INPUT
Operating Voltage: 120, 240 VAC; 12 VDC; 24
VAC/DC ±10% (DC models have reverse polarity
protection. Unfiltered input voltage to them must
be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state normally open
Rating: 1 A steady state
Life: 100,000,000 cycles
PROTECTION
Transient Voltage: 30 joule metal oxide varistor,
see ratings below
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Isolation Resistance: 100 megohms min.
between terminals and case

12 VDC +10%

24 VAC/DC +10%

120 VAC +10%

240 VAC +10%

.05 to 1 sec.

Q3F-00001-326

Q3F-00001-327

Q3F-00001-321

—

.25 to 5 sec.

Q3F-00005-326

—

Q3F-00005-321

Q3F-00005-325

.5 to 10 sec.

Q3F-00010-326

Q3F-00010-327

Q3F-00010-321

Q3F-00010-325

3 to 60 sec.

Q3F-00060-326

Q3F-00060-327

—

—

15 to 300 sec.

—

Q3F-00300-327

Q3F-00300-321

Q3F-00300-325

30 to 600 sec.

—

Q3F-00600-327

—

—

180 to 3600 sec.

Q3F-03600-326

Q3F-03600-327

Q3F-03600-321

Q3F-03600-325

.25 to 5 hrs.

—

Q3F-18000-327

Q3F-18000-321

—

.5 to 10 hrs.

Q3F-36000-326

—

Q3F-36000-321

Q3F-36000-325

Trigger time (start switch closure)

20 ms

20 ms

20 ms

20 ms

Reset time

200 ms

300 ms

200 ms

200 ms

5 mA

5 mA

2 mA

2 mA

Min. load
Max. leakage current

10 uA

10 uA

200 uA

300 uA

Voltage drop at 1 A

2.1 V max.

3.2 V max.

3.3 V max.

3.3 V max.

Power consumption

2.6 W

3.7 VA max.

4.3 VA max.

5.8 VA max.

Peak 1 cycle surge

4A

4A

20 A

20 A

8.8j. MOV

8.8j. MOV

30j. MOV

30j. MOV

Protection

Optional Potentiometer: Part Number ASY-0001M-450

MECHANICAL
Termination: .25” x .032” male fast-on
terminals
Mounting: Surface mount with one #8
screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
.25 X .032 MALE FAST-ON
TERMINALS (7 PL.)

.88
1.25

2.00 SQ.
Rt

5

4
CL

CL
7

TIME RANGE

Start
Switch

On
Off

6

ORDERING INFORMATION

Input
Voltage

START
SWITCH

1

2

3

.170
DIA.

LOAD
(3667-4)

INPUT
VOLTAGE

Polarity Shown is
for DC Models
External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.
Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-22

TIME DELAY RELAYS

Delay On Break (Retriggerable)
K3 Series

SPECIFICATIONS

● 100% functionally tested
● No false contact transfer when reset

TIME DELAY
Adjustment: Knob, factory fixed on special
order (min. order required)
Range: 100 ms to 5 min. in 3 ranges
Repeatability: ±3% at constant temperature
Accuracy:
Maximum time: +10%/-0%
Minimum time: -50%/+0%
Reset Time: 150 ms max.
Start Switch Closure Time: 50 ms to initiate timing; 100 ms to reset delay during timing
INPUT
Operating Voltage: 120 VAC ±10%
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC 100 mA at
5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: 120 V timers are protected by
a 5 joule metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: Spade (.187” x .020” terminal) type
plug-in base
Mounting: Socket mount, part number
MSO-00KUP-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

●
●
●
●
●
●
●
●
●

during timing
Digital timing circuit
Time delays to 5 minutes
Low cost
Compact size
Spade type base
Wide operating temperature range
Fiberglass reinforced circuit board
Polycarbonate, 94V-2 housing material
File #E59090

Operating Logic: Input voltage is applied
to the timer at all times. Upon a closure of
a normally open isolated start switch, the
output relay is activated and remains so
as long as the switch is kept closed. When
the start switch is opened, timing starts. At
the end of the preset time delay, the output
relay is deactivated and the timer is ready
for a new cycle.
Note: 1) Do not apply voltage or ground to the start switch; 2)
Switch leads should be shielded when running close to other
wires; 3) If the start switch is re-closed during timing, the timer
will reset and will not start timing until start switch is opened (Start
switch supplied by customer).

LOGIC FUNCTION DIAGRAM
Input
Voltage
Start
Switch

On
Off
Closed
Open
Timing

Relay
Coil

Case 6

2.125

.70
Max.

1.531

Start Switch
(By Cust.)

1
4
7
A

+

On
Off

.25

(3021-4)

1.406

FEATURES

5
8

3
6
9
B

-

Input
Voltage
Polarity Shown is
for D.C. Models

Delay On Break Function

ORDERING INFORMATION
TIME RANGE

120 VAC

.1 to 10 sec.

K3K-00010-661

.6 to 60 sec.

K3K-00060-661

3 to 300 sec.

K3K-00300-661

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-23

TIME DELAY RELAYS

Delay On Break (Retriggerable)
Z3 Series

LOGIC FUNCTION DIAGRAM
Input
Voltage
Start
Switch

On
Off

1.500

.313
±.032
R

R

N.C.

N.C.

N.0.

N.0.

COM

COM

L2 +

INPUT
VOLTAGE

120 VAC

L1 -

R12

Polarity shown
for DC models

TIME ADJUST

INC

START SWITCH

.187

.313 ±.032
START
SWITCH

.27
1.875

Note: 1) Do not apply voltage or ground to the start switch; 2)
Switch leads should be shielded when running close to other
wires; 3) If the start switch is re-closed during timing, the timer
will reset and will not start timing until start switch is opened (Start
switch supplied by customer).

.250 X .032 MALE 'FAST-ON'
(10 PL.)
2.125 ±.032

.775

Operating Logic: Voltage is applied to the
timer at all times. Upon a closure of a normally open isolated start switch, the output
relay is activated and remains so as long as
the switch is kept closed. When the start
switch is opened, timing starts. At the end
of the preset time delay, the output relay is
deactivated and the timer is ready for a new
cycle.

CLEARANCE FOR #6 SCREW
(4 PL.)

K1

during timing
Digital timing circuit
Time delays to 5 minutes
±1% repeatability
Superior transient protection
Fast-on terminals for quick installation
Low cost, open board construction
Fiberglass reinforced circuit board
Trimpot on-board with sealed cermet
element
●
File #E59090

●
●
●
●
●
●
●
●

Z3T-*****-061

TIME DELAY
Adjustment: Trimpot, factory fixed on special order (min. order required)
Range: 3 to 300 sec.
Repeatability: ±1% at constant temperature
Accuracy:
Maximum time -0%, +10%
Minimum time +0%, -50%
Reset Time: 300 ms max.
Start Switch Closure Time: 20 ms to initiate timing; 50 ms to reset delay during timing
INPUT
Operating Voltage: 120 VAC ±10%
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC - 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: Timers are protected by a 30
joule metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: .25” standoffs, #6 screw
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

3.000

SPECIFICATIONS

● 100% functionally tested
● No false contact transfer when reset

3.625 .±032

FEATURES

Closed
Open
Timing

Relay
Coil

On
Off

6360

Delay On Break Function

ORDERING INFORMATION
TIME RANGE
3 to 300 sec.

120 VAC
Z3T-00300-061

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-24

TIME DELAY RELAYS

Interval
S1 Series

On
Off

Relay
Coil

On
Off

Timing

Interval Function

8

6

1

2.40

Input
Voltage

.53

7

LOGIC FUNCTION DIAGRAM

2.90

.85

4

Operating Logic: Upon application of voltage to the input terminals, the relay coil is
activated and the timing cycle starts. At the
end of the preset time delay, the relay coil
is deactivated. Reset is accomplished by
removal of the input voltage.

5

TIME DELAY
Adjustment: Knob, factory fixed on special order
(min. order required)
Range: 50 ms to 1 hour in 6 ranges
Repeatability: ±1% at constant temperature
Accuracy:
Maximum time -0%, +10%
Minimum time +0%, -50%
Reset Time: 50 ms max.
INPUT
Operating Voltage: 24, 120 VAC; 12, 24 VDC
±10% (DC models have reverse polarity protection; unfiltered input voltage to them must be fullwave rectified)
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC 100 mA at
5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500.000 operations
PROTECTION
Transient Voltage: 12 and 24 V timers are protected by an 8.8 joule metal oxide varistor; 120
V timers are protected by a 30 joule metal oxide
varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 8-pin plug-in base
Mounting: Socket mount, part number
MSO-0008P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Digital timing circuit
Time delays to 1 hour
±1% repeatability
Superior transient protection
Fiberglass reinforced circuit board
Internal components supported by
heavy-duty chassis
● Reinforced base locator pin
● Flame-retardant polycarbonate housing
●
File #E59090

2

SPECIFICATIONS

●
●
●
●
●
●
●

3

FEATURES

1.75
(3012-4)

4
3

5

6
7

2

8
Input
Voltage

1

PIN CONFIGURATION
Polarity Shown is
for D.C. Models

ORDERING INFORMATION
12 VDC

24 VDC

24 VAC

120 VAC

.05 to 5 sec.

TIME RANGE

—

—

—

S1K-00005-461

.1 to 10 sec.

S1K-00010-466

S1K-00010-462

S1K-00010-467

S1K-00010-461

.6 to 60 sec.

S1K-00060-466

S1K-00060-462

—

S1K-00060-461

1.8 to 180 sec.

—

—

S1K-00180-467

S1K-00180-461

6 to 600 sec.

—

—

—

S1K-00600-461

36 to 3600 sec.

—

—

—

S1K-03600-461

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-25

TIME DELAY RELAYS

Interval (Relay Output)
Q4T Series
FEATURES

SPECIFICATIONS

●
●
●
●
●
●
●
●
●

TIME DELAY
Adjustment: On-board Trimpot
Range: 50 ms to 10 hours in 8 ranges
Repeatability: ±0.5% max. (0.25% typical) at
constant temperature
Accuracy:
Maximum time +10%, -0%
Minimum time -30%, +0%
Reset Time: .25 sec. max., by removal of the
input voltage
INPUT
Operating Voltage: 120 VAC ±10%
Power Consumption: 3.5 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, SPDT (1 form C)
Rating: 8 A max. resistive at 250 VAC and 30
VDC; 100 mA at 5 VDC min. load current
Life:
Mechanical: 10,000,000 cycles;
Electrical: 100,000 min. at full load
PROTECTION
Transient Voltage: 1000 P.I.V. components used
Isolation Resistance: 100 megohms min.
between terminals and case
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting; 1500 VAC, RMS, input to
output
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 70°C
Operating Temperature: -40°C to 70°C
Humidity: 95% relative

100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Sealed S.P.D.T output contacts
Compact size
Superior transient protection
Epoxy encapsulated
Flame-retardant and solvent-resistant
polyester thermoplastic housing
● Trimpot on-board with sealed cermet
element
●
File #E65038
Operating Logic: Upon application of voltage to the input terminals, the relay is energized, the contacts transfer and the timing
cycle starts. At the end of the preset time
delay, the relay coil is de-energized and the
contacts return to their original state. Reset
is accomplished by removing voltage from
the input terminals.
LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Relay
Coil

On
Off

Timing

Interval Function

CL

.885
1.25
.25 X .032 MALE FAST-ON
TERMINALS (5 PL.)

ISOLATED
OUTPUT CONTACTS
TIME DELAY
ADJUSTMENT ACCESS
2.00 SQ.

CL N.C.

N.O.

CL
C

ORDERING INFORMATION
TIME RANGE

120 VAC +10%

.05 to 1 sec.

Q4T-00001-341

.25 to 5 sec.

Q4T-00005-341

.5 to 10 sec.

Q4T-00010-341

3 to 60 sec.

Q4T-00060-341

15 to 300 sec.

Q4T-00300-341

30 to 600 sec.

Q4T-00600-341

18 to 3600 sec.

Q4T-03600-341

.5 to 10 hrs.

Q4T-36000-341

.170 DIA.
(3667-3)

-

INPUT
VOLTAGE

+

Polarity Shown is
for DC Models

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-26

TIME DELAY RELAYS

Interval

Q4F Series
FEATURES

SPECIFICATIONS

●
●
●
●
●
●
●
●

100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038
Operating Logic: Upon application of input
voltage the load energizes and the timing
cycle starts. At the completion of the preset
time delay, the load is de-energized. Reset
is accomplished by removal of input voltage.
Note: 1) Remote potentiometer leads should be shielded when
running close to other wires; 2) The minimum time setting on
external resistor-adjustable time delay relays is obtained by shorting together the external resistor terminals of the relay; 3) The
maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 4) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 5)
Recommend 1/4 W minimum resistor be used.

LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Load

On
Off

Timing

Interval Function

TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order required)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohm
Minimum time +0%-30% at Rt = 0 ohm
INPUT
Operating Voltage: 120, 24 VAC/DC ±10% (DC
models have reverse polarity protection; unfiltered
input voltage to them must be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open
Rating: 1 A steady state
Life: 100,000,000 operations
PROTECTION
Transient Voltage: Metal oxide varistor, see ratings below
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

.25 X .032 MALE FAST-ON
TERMINALS (7 PL.)

.88
1.25

2.00 SQ.
Rt

5

4
CL
CL

1

2

3

.170
DIA.

LOAD

ORDERING INFORMATION
TIME RANGE

12 VDC +10%

(3667-7)

24 VAC/DC +10%

120 VAC +10%

240 VAC +10%

.05 to 1 sec.

Q4F-00001-326

—

Q4F-00001-321

Q4F-00001-325

.25 to 5 sec.

Q4F-00005-326

Q4F-00005-327

Q4F-00005-321

Q4F-00005-325

.5 to 10 sec.

Q4F-00010-326

Q4F-00010-327

Q4F-00010-321

Q4F-00010-325

3 to 60 sec.

Q4F-00060-326

Q4F-00060-327

Q4F-00060-321

—

15 to 300 sec.

Q4F-00300-326

—

Q4F-00300-321

—

30 to 600 sec.

Q4F-00600-326

—

Q4F-00600-321

Q4F-00600-325

180 to 3600 sec.

Q4F-03600-326

Q4F-03600-327

Q4F-03600-321

—

.25 to 5 hrs.

—

Q4F-18000-327

Q4F-18000-321

—

.5 to 10 hrs.

Q4F-36000-326

Q4F-36000-327

Q4F-36000-321

Q4F-36000-325

Trigger time (start switch closure)

75 ms

50 ms

150 ms

150 ms

Reset time

75 ms

50 ms

150 ms

150 ms

Min. load

5 mA

5 mA

2 mA

2 mA

Max. leakage current

20 uA

20 uA

100 uA

100 uA

Voltage drop at 1 A

2.1 V

3.2 V

3.3 V

3.3 V

Power consumption

3.0 W max.

3.0 VA max.

3.0 VA max.

3.0 VA max.

Peak 1 cycle surge
Protection

4A

4A

20 A

20 A

rev. V / 8.8j. MOV

8.8j. MOV

30j. MOV

30j. MOV

Optional Potentiometer: Part Number ASY-0001M-450

INPUT
VOLTAGE

Polarity Shown is
for DC Models

External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-27

Interval
Z4 Series

SPECIFICATIONS

● 100% functionally tested
● No false contact transfer when reset

TIME DELAY
Adjustment: Trimpot, factory fixed on special order (min. order required)
Range: 3 to 300 sec. (other ranges available on special order)
Repeatability: ±1% at constant
temperature
Accuracy:
Maximum time -0%, +10%
Minimum time +0%, -50%
Reset Time: 400 ms max.
INPUT
Operating Voltage: 120 VAC ±10%
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: Timers are protected by a 30
joule metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: .25” standoffs. #6 screw
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

during timing
Digital timing circuit
Time delays to 5 minutes
±1% repeatability
Fast-on terminals for quick installation
Low cost, open board construction
Fiberglass reinforced circuit board
Trimpot on-board with sealed cermet
element
●
File #E59090

●
●
●
●
●
●
●

Operating Logic: Upon application of voltage to the input terminals, the relay coil is
activated and the timing cycle starts. At the
end of the preset time delay, the relay coil
is deactivated. Reset is accomplished by
removal of the input voltage.
LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Relay
Coil

On
Off

Timing

Interval Function

.25 X .032 Male
Fast-on (16 Pl.)
2.125
1.50

.313
Typ.

NC

NC

NO

NO

C

C

3.00
3.625

FEATURES

INC

L1

L2

Input
.141 Dia.
Voltage
(4 Holes)
Polarity is shown
for DC models
Time Adjust

.27
1.875

(3021-1)

ORDERING INFORMATION
TIME RANGE
3 to 300 sec.

120 VAC
Z4T-00300-061

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-28

TIME DELAY RELAYS

Repeat Cycle
CKK Series

Input
Voltage

On
Off

Relay
Coil

On
Off

Adj. "On" Delay

Adj. "Off" Delay
Repeat Cycle Function

.53
(3012-6)

1

8

2.40

LOGIC FUNCTION DIAGRAM

2.90

.63

6

Operating Logic: Upon application of voltage to the input terminals, the OFF delay is
initiated. At the end of the OFF preset time,
the relay coil is activated and the ON delay
starts. At the end of the ON preset time, the
relay coil is deactivated and a new cycle
begins. The ON and OFF cycles will continue to alternate until voltage is removed.

7

●
●
●

4

●
●

5

TIME DELAY
Adjustment: Knobs, factory fixed on special
order (min. order required)
Range: 50 ms to 1 hour in 8 ranges
Repeatability: ±1% at constant temperature
Accuracy:
Maximum time -0%, +10%
Minimum time +0%, -50%
Reset Time: 500 ms max.
INPUT
Operating Voltage: 12, 24 VDC; 24, 120 VAC
±10% (DC models have reverse polarity protection; unfiltered input voltage to them must be fullwave rectified)
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: 12 and 24 V timers are protected by an 8.8 joule metal oxide varistor 120
V timers are protected by a 30 joule metal oxide
varistor
Dielectric Breakdown: 1500 V RMS min. at 60
Hz between input and outputs and between outputs
MECHANICAL
Termination: 8-pin plug
Mounting: Socket mount, part number
MSO-0008P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Digital timing circuit
Time delays to 10 hours
±1% repeatability
Individually adjustable ON and OFF
times
Fiberglass reinforced circuit board
Internal components supported by
heavy-duty chassis
Reinforced base locator pin
Polycarbonate flame-retardant housing
File #E59090

2

SPECIFICATIONS

●
●
●
●
●

3

FEATURES

1.75
(3012-4)

4
3

5

6
7

2

8
Input
Voltage

1

PIN CONFIGURATION
Polarity Shown is
for DC Models

ORDERING INFORMATION
12 VDC

24 VDC

24 VAC

120 VAC

.05 to 5 sec.

TIME RANGE

—

—

—

CKK-00005-461

.1 to 10 sec.

CKK-00010-466

CKK-00010-462

CKK-00010-467

CKK-00010-461

.6 to 60 sec.

CKK-00060-466

CKK-00060-462

CKK-00060-467

CKK-00060-461

1.8 to 180 sec.

CKK-00180-466

CKK-00180-462

CKK-00180-467

CKK-00180-461

3 to 300 sec.

—

—

—

CKK-00300-461

6 to 600 sec.

—

—

—

CKK-00600-461

18 to 1800 sec.

—

—

—

CKK-01800-461

36 to 3600 sec.

—

—

—

CKK-03600-461

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-29

TIME DELAY RELAYS

Repeat Cycle
Q6F Series
FEATURES

LOGIC FUNCTION DIAGRAM

●
●
●
●
●
●
●
●

100% functionally tested
Solid state digital timing
Time delays to 10 hours standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038
Operating Logic: Upon application of input
voltage, the OFF delay is initiated. At the
end of the OFF preset time, the load is activated and the ON delay starts. At the end of
the ON preset time, the load is deactivated
and a new cycle begins. The ON and OFF
cycles will continue to alternate until input
voltage is removed.
This timer is available with ON time
occurring first logic.
Note: 1) Remote potentiometer leads should be shielded when
running close to other wires; 2) The minimum time setting on
external resistor-adjustable time delay relays is obtained by shorting together the external resistor terminals of the relay; 3) The
maximum time setting within tolerance limits is obtained by using
a 1 megohm resistor; 4) Timing values between the minimum
and maximum limits are linear with resistance within 10%; 5)
Recommend 1/4 W minimum resistor be used.

ORDERING INFORMATION

Adj. "Off" Delay

On
"Off" Time
Load Off
First
Adj. "On" Delay
Adj. "On" Delay

On
"On" Time
Load
Off
First
Adj. "Off" Delay

SPECIFICATIONS
TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order requirement)
Range: 50 ms to 10 hours in 9 ranges
Repeatability: ±.5% +8 ms max. (.25% typical) at
constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohm
Minimum time +0%, -30% at Rt = 0 ohm
INPUT
Operating Voltage: 120, 240 VAC; 12 VDC; 24
VAC/DC ±10%; (DC models have reverse polarity
protection. Unfiltered input voltage to them must
be full-wave rectified)
Frequency: 50/60 Hz
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
OUTPUT
Type: Solid state, normally open
Rating: 1 A steady state
Life: 100,000,000 operations
24 VAC/DC +10%

120 VAC +10%

PROTECTION
Transient Voltage: Metal oxide varistor
see rating below
Dielectric Breakdown: 3000 VAC,
RMS, terminals to mounting
Insulation Resistance: 100 megohms
min. between terminals and case
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative
.25 X .032 MALE FAST-ON
TERMINALS (7 PL.)

.88
1.25

2.00 SQ.

240 VAC +10%
Rt

Q6F-00001-326
Q6F-00005-326
Q6F-00010-326
Q6F-00060-326
—
Q6F-00600-326
—
Q6F-18000-326
—

Q6F-00001-327
Q6F-00005-327
Q6F-00010-327
Q6F-00060-327
Q6F-00300-327
—
—
—
—

Q6F-00001-321
Q6F-00005-321
Q6F-00010-321
Q6F-00060-321
Q6F-00300-321
Q6F-00600-321
Q6F-03600-321
—
—

Q6F-00001-325
Q6F-00005-325
Q6F-00010-325
Q6F-00060-325
Q6F-00300-325
Q6F-00600-325
—
Q6F-18000-325
Q6F-36000-325

Q6F-00060-336
—

—
—

Q6F-00060-331
Q6F-00600-331

—
—

500 ms
500 ms
5 mA
100 uA
2.1 V max.
2.6 W max.
4A
rev. voltage

500 ms
500 ms
5 mA
100 uA
3.2 V max.
3.7 VA max.
4A
8.8j. MOV

500 ms
500 ms
2 mA
100 uA
3.3 V max.
4.3 VA max.
20 A
30j. MOV

500 ms
500 ms
2 mA
100 uA
3.3 V max.
5.8 VA max.
20 A
30j. MOV

5
Rt

On Time

4
CL
CL

7

Trigger time (start switch closure)
Reset time
Min. load
Max. leakage current
Voltage drop at 1 A
Power consumption
Peak 1 cycle surge
Protection

12 VAC/DC +10%

On
Off

6

TIME RANGE
OFF TIME FIRST LOGIC
.05 to 1 sec.
.25 to 5 sec.
.5 to 10 sec.
3 to 60 sec.
15 to 300 sec.
30 to 600 sec.
180 to 3600 sec.
.25 to 5 hrs.
.5 to 10 hrs.
ON TIME FIRST LOGIC
3 to 60 sec.
30 to 600 sec.

Input
Voltage

Off Time

1

2

3

.170
DIA.

LOAD

Optional Potentiometer: Part Number ASY-0001M-450
Consult factory for any special requirements not listed in catalog (minimum order requirement may apply).

(3667-8)

INPUT
VOLTAGE

Polarity Shown is
for DC Models
External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:
Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-30

TIME DELAY RELAYS

Flasher

Q8F Series
FEATURES

LOGIC FUNCTION DIAGRAM

●
●
●
●
●
●
●
●
●

100% functionally tested
Only one timing component required
Solid state digital timing
Time delays to 5 minutes standard
20:1 maximum to minimum timing ratio
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038
Operating Logic: Upon application of voltage to the input terminals, the load is energized for the duration of the preset time
delay. At the end of this time delay, the load
is de-energized for the duration of the preset time delay. The load is then energized
again and the timer continues to repeat this
on-off cycle until input voltage is removed.
Both on and off times are the same and are
determined by Rt.
Note: 1) Rt and terminals 4 and 5 are used for external time
adjustment; 2) Remote potentiometer leads should be shielded
when running close to other wires; 3) The minimum time setting
on external resistor-adjustable time delay relays is obtained by
shorting together the external resistor terminals of the relay; 4)
The maximum time setting within tolerance limits is obtained by
using a 1 megohm resistor; 5) Timing values between the minimum and maximum limits are linear with resistance within 10%;
6) Recommend 1/4 W minimum resistor be used.

ORDERING INFORMATION
TIME RANGE

120 VAC +10%

.05 to 1 sec.

Q8F-00001-321

.25 to 5 sec.

Q8F-00005-321

.5 to 10 sec.

Q8F-00010-321

3 to 60 sec.

Q8F-00060-321

15 to 300 sec.

Q8F-00300-321

Trigger time (start switch closure)

500 ms

Reset time

500 ms

Min. load
Max. leakage current

3.3 V

Power consumption

4.3 VA max.

Protection

On
Off

Load

On
Off

Timing

Timing

.25 X .032 MALE FAST-ON
TERMINALS (5 PL.)

SPECIFICATIONS
TIME DELAY
Adjustment: External resistor, factory fixed on
special order (min. order requirement)
Range: 50 ms to 5 minutes in 5 ranges
Repeatability: ±.5% +8 ms max. (0.25% typical)
at constant temperature
Accuracy:
Maximum time ±2% at Rt = 1 megohm
Minimum time +0%, -30% at Rt = 0 ohm
INPUT
Operating Voltage: 120 VAC ±10%
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open
Rating: 1 A steady state
Life: 100,000,000 operations
PROTECTION
Transient Voltage: Metal oxide varistor (see rating below)
Dielectric Breakdown: 3000 VAC, RMS, terminals to mounting
Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 65°C
Humidity: 95% relative

.88
1.25

2.00 SQ.
Rt

5

20 A
30j. MOV

Optional Potentiometer: Part Number ASY-0001M-450

4
CL
CL

1

2

3

.170
DIA.

LOAD

(3667-7)

INPUT
VOLTAGE
Polarity Shown is
for DC Models

External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain
the maximum time for all ranges. To determine the
actual resistance needed to obtain the required time
delay, use the following formula:

2 mA
100 uA

Voltage drop at 1 A
Peak 1 cycle surge

Input
Voltage

Rt=

Trequired - Tminimum
Tmaximum - Tminimum

x 1,000,000 ohms

Note: Due to component tolerances, the actual time
obtained will normally be within 5% of desired time.
Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TIME DELAY RELAYS

1-31

Repeat Cycle
Z6 Series

●
●
●
●
●

Operating Logic: Upon application of voltage to the input terminals, the OFF delay is
initiated. At the end of the OFF preset time,
the relay coil is activated and the ON delay
starts. At the end of the ON preset time, the
relay coil is deactivated and a new cycle
begins. The ON and OFF cycles will continue to alternate until voltage is removed.
LOGIC FUNCTION DIAGRAM
Input
Voltage

On
Off

Relay
Coil

On
Off

Adj. "On" Delay

CLEARANCE FOR #6 SCREW
(4 PL.)
"ON" DELAY
ADJUSTMENT

INC

"OFF" DELAY
ADJUSTMENT

INC

INPUT
VOLTAGE

- +

3.50

●

3.00

TIME DELAY
Adjustment: Trimpot, factory fixed on special
order (min. order required)
Range: .1 to 10 sec.
Repeatability: ±1% at constant temperature
Accuracy:
Maximum time -0%, +10%
Minimum time +0%, -50%
Reset Time: 500 ms max.
INPUT
Operating Voltage: 120 VAC ±10%
Power Consumption: 3 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay DPDT (2 form C)
Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
PROTECTION
Transient Voltage: Timers are protected by a 30
joule metal oxide varistor
Dielectric Breakdown: 1500 V RMS min. at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: .25” standoffs, #6 screw
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Digital timing circuit
Time delays to 10 seconds
±1% repeatability
Individually adjustable ON and OFF
times
Components protected by conformal
coating
Low cost, open board construction
Superior transient protection
Fiberglass reinforced circuit board
Trimpot on-board with sealed cermet
element
File #E59090

R

SPECIFICATIONS

●
●
●
●
●

Z6T-180/5-001

FEATURES

L2

L1
COM

COM
N.0.

N.0.

N.C.

N.C.

1.50
2.00

.250

Adj. "Off" Delay
.250 X .031 MALE 'FAST-ON'
(8 PL.)

Repeat Cycle Function

.27

1.875

Polarity shown
for DC models

3310/12/92

ORDERING INFORMATION
TIME RANGE
.1 to 10 sec.

120 VAC
Z6T-00010-061

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-32

TIME DELAY RELAYS

Universal Voltage Input Buffer
ASY-INPUT-BUFR
FEATURES

SPECIFICATIONS

● Universal control voltage range: 12 to

INPUT
AC: 10.6 to 265 VAC 50/60 Hz, 5 mA max.
DC: 10.6 to 265 VDC 5 mA max.
Input-Output Delay: 50 ms max.
OUTPUT
Effective contact closure for NCC timers:
Closure: VAC = 9 to 265, 50/60 Hz (6 mA max.)
Closure: VDC = 9 to 265, (6 mA max.)
Voltage drop across output: 2.2 VAC/VDC max.
at I=6 ma
Output leakage: At Vin= 0 VDC and Vout = 265
VDC, leakage is 25 uA DC max.
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Dielectric breakdown: 3000 Vrms terminal to
mounting; 1500 Vrms input to output
Insulation resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals
Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage temperature: -40°C to 85°C
Operating temperature: -40°C to 65°C
Humidity: 95% relative max.

●
●
●
●
●
●
●
●
●
●

240 VAC/DC
Controls all NCC timers requiring start
switch input
No need for isolated start switch contacts
Easy interface to programmable logic
controllers
Completely solid state, no moving parts
to wear out
Circuitry completely encapsulated
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
File #E164906

The universal input buffer will take any voltage from 10.6 to 265 VAC/DC and actuate
any NCC timer requiring a start switch to
initiate a timing cycle.
Operating Logic: Upon application of input
voltage, the output becomes an effective
contact closure (within 50 ms). Upon removal of input voltage, the output becomes an
effective open circuit (within 50 ms).

1.25
.885

.250 X .032 MALE
SPADE TERMINAL
(4 PLACES)
TO NCC
TIMER-TRIGGER
INPUTS

LOGIC FUNCTION DIAGRAM
5

Output

On
Off
Closed
Open

(TO START SW)

50 mSec.
max.

50 mSec.
max.

National Controls
Corporation
West Chicago, IL.
60185

INPUT BUFFER

2.00 SQ.

Control
Input

4
OUTPUT

Model No.:
ASY-INPUT-BUFR

1

CONTROL INPUT
12-240 VAC/DC

3

.170
DIA.

V
INPUT VOLTAGE SOURCE
(Typical Wiring Diagram)

ORDERING INFORMATION
INPUT VOLTAGE RANGE
12 to 240 VAC/DC

PART NUMBER
ASY-INPUT-BUFR

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-33

TIME DELAY RELAYS

Fan and Light Control
Model T1517

Fan

WIRING DIAGRAM

LIGHT

.906
1.562
.781

#6-32X7/8 SCREW (2 PL.)
PROVIDED FOR BOX
MOUNTING

.187 X .50
SLOT (2 PL.)

C
L

SATIN ALUMINUM
WALL PLATE

R

Off

TIME

TIME SET
(MINUTES)

On

Min.
Max.

1

2.063

1.640

2.75
4.125

C
L

R

On

3.281

ON

Time

2.375

1.187

National Controls
Corporation
West Chicago, IL. 60185
P/N TNC-T1517-120

On

Off

1.3

15

60

30
45

Delay
1-60 Minutes

TIMING DELAY
ADJUSTMENT

WIRING DIAGRAM

LINE (BLK)
120 VAC
NEUTRAL

5.0

Light

.5" ± .125" STRIP AND TIN TYP.
.50

1.812

LOGIC FUNCTION DIAGRAM

Switch

LENGTH MEASURED
FROM THE COVER: 5.5" ± 1.0",

FAN
MOTOR

Operating Logic: Voltage is applied to the
unit at all times via the black and white
wires. When the switch is placed in the ON
position, power is applied to the lamp and
fan output. When the switch is placed in the
TIMED position, the power is removed from
the lamp output and the fan output stays
on for the preset delay time. After the delay
time the power is removed from the fan output.
Should the switch be placed in the ON
position during the delay time, the timer will
be reset and both outputs will be ON as
defined above.
Should power be interrupted, when in the
TIMED position, the timer will be reset and
when power is re-applied the fan output will
be ON for the preset delay time after the
power is re-applied.

ALL 4 WIRES ARE 18 AWG,
U.L. STYLE 1015, .031 INSULATION

RED

exhaust fan off
Adjustable fan turn off time
Fits single switch outlet box
Simple wire nut hook-up
Cover plate and hardware provided
File #E95644

BLUE

●
●
●
●
●

(WHT)

TIME DELAY
Adjustment: On-board Trimpot
Range: 1 to 60 minutes
Repeatability: ±0.5% +8ms max.
Accuracy:
Maximum time -0%, +10%
Minimum time -30%, +0%
INPUT
Operating Voltage: 120 VAC ±10%
Power Consumption: 3.5 VA max. at 120 VAC
(exclusive of loads)
Frequency: 50/60 Hz
OUTPUT
A-Lamp Load (Switch): 500 W at 120 VAC max.
(blue wire)
B-Fan Load (Switch and Relay Contact):
1/3 hp, 10 A (resistive) at 120 VAC max. (red wire)
Life: 100,000 cycles at full load
MECHANICAL
Mounting: Fits single switch outlet box
Electrical: Simple wire nut hook-up
Switch color: Black
ENVIRONMENTAL
Storage Temperature: -40°C to 70°C
Operating Temperature: -40°C to 55°C
Humidity: 95% relative

LINE (BLK)

SPECIFICATIONS

● One switch controls fan and light
● Digital timing circuit
● Saves energy by automatically turning

120 VAC NEUTRAL

FEATURES

BLUE

RED

LAMP

(WHT)
FAN
MOTOR

5801

1.7

ORDERING INFORMATION

WALL PLATE
(ATTACH AFTER INSTALLATION OF UNIT)

INPUT VOLTAGE

ADJ. OFF DELAY

SWITCH COLOR

PART NUMBER

120 VAC

1 to 60 min.

BLACK

TNC-T1517-120

120 VAC

1 to 60 min.

WHITE

TNC-T1517-120W

Note: The following hardware is supplied with this
product: 2 screws for unit / wall mounting; satin
aluminum wall plate with 2 screws; 4 wire connectors
(screws and wire connectors packed in plastic bag)

Consult factory for any special requirements not listed in catalog (minimum order requirement may apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-34

TIMER ACCESSORIES

Potentiometer

3/8"

3/8" x 32 THREADS

NCC remote mounting potentiometers have 24”
wire leads, dust protection, 1/4” shaft (no knob)
and are calibrated to provide constant timing.
These are suitable for mounting through a panel
and can be used with a dial and knob.
A locking bushing is used in place of knob to
secure setting. Not for use on K or CKK Series
timers.

22 GA. .032 - 105˚ C UL STYLE 1015 WIRE

24" ± 1"
3/8" x 32 NUT

INSULATING TUBING OVER TERMINALS

ORDERING INFORMATION
1 Megohm remote potentiometer

ASY-0001M-450

Locking bushing

MLO-K1701-011

1/4" x .032 FEMALE FASTONS

Dial Plate
Range 1 to 100% Dial Plate is shown, others
shown in chart are typical.

.375 dia.

ORDERING INFORMATION
Dial Plate - Range: .05 to 2 sec.

MDP-00002-011

Dial Plate - Range: .05 to 5 sec.

MDP-00005-011

Dial Plate - Range: .1 to 10 sec.

MDP-00010-011

Dial Plate - Range: .3 to 30 sec.

MDP-00030-011

Dial Plate - Range: .6 to 60 sec.

MDP-00060-011

Dial Plate - Range: 1.2 to 120 sec.

MDP-00120-011

Dial Plate - Range: 1.8 to 180 sec.

MDP-00180-011

Dial Plate - Range: 3 to 300 sec.

MDP-00300-011

Knob: 1” skirt, 1/4” hole, brass insert

MKN-TK191-011

60
40

80

CL

.900

MDP-0100%-011

2.00

Dial Plate - Range: 1 to 100%

20
1

% 100

.625

2.00

MKN-TK191-011

.05

5.75

Hold-down Straps

.33

.45

A locking bushing is used in place of knob to
secure setting. Used on all plug in timers with
knobs except K and CKK Series.

.500
.437

.065 ± .015

.57

ORDERING INFORMATION
Hold-down strap for K Series timers

7.00

ASY-STRAP-5.75L

.50

.25

.33

.50 typ.

.45

Hold-down strap for T, S, A, and CKK
timers

ASY-STRAP-7.00L

Locking bushing

MLO-010MM-.75
.065 ± .015

1.85
1.76

Mounting Bracket
ORDERING INFORMATION
Mounting bracket for 1/16 DIN
enclosure

MBK-1/16D-011

.16
.28

1.76
.90

2.26

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1-35

TIMER ACCESSORIES

Sockets

1.575

.866

.315

.709

MSO-0008P-012

2.362

8-pin circular socket, DIN rail
mountable

165 dia.

5

4

3

7

8

1

2

Mounting Holes
.165 dia. 2 pl.

.984

ORDERING INFORMATION

6

1.299

1.299

2.323

.315

MSO-0011P-012

.165 dia.

2.632

11-pin circular socket, DIN rail
mountable

8

7

9

10

6

5

4

2

3

Mounting Holes
.165 dia. 2 pl.

1.063

ORDERING INFORMATION

Terminal
Arrangement

1.299

1.299

11

1

Top View

.709
.866

1.312

4

1.844

11-pin circular socket for DIN panel
mount

8

7

.156

ORDERING INFORMATION

6

5

MSO-0011P-013

3

2 1

11

10 9

1.844

0.315

11-pin spade socket, DIN rail
mountable

6

5

4

3

2

1

0.165 DIA
Mounting Holes (2)

2.205

0.165

2.992

ORDERING INFORMATION

Terminal
Arrangement

0.709

1.457

MSO-00KUP-012

B
9
1.417
1.693

0.571

A
8

7

Top View

0.987

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

Notes

2-1

AMETEK NCC has been designing and manufacturing liquid level controls for more than 25
years, producing controls that exceed user
standards and expectations for long-life and
reliability.
Standard logic functions include Pump-Up
and Pump-Down models. Different model features include Dual Probe Resistance Sensors,
Low Water Detect Resistance Sensors, PumpUp Logic with Time Delayed Output, Pump-Up
Logic with Heater Burn Out Protection, Dual
Probe/Dual Logic Resistance Sensors and
Single Probe Sensors.
In addition, AMETEK NCC offers impressive
factory back-up support. Our parts inventory
and product availability is unsurpassed. With
over 250 stocking distributor outlets, serious
downtime problems can virtually be eliminated. Technical assistance for design and
engineering help is readily available through
our toll free number: 800-323-2593.

Common Applications:
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

Low Level Pump Controls
Metering Systems
Conveyor Motor Controls
Milk Receiver Pump Controls
Industrial Wastes Pump Controls
Low Water Cutoff and Alarms
Steam Boilers
Foam/Liquid Interface Indication
Deep Well Pump Low Level Cutoff
Water Tank Control
Solenoid Valve Control
Motorized Valve Control
Food Processing Control
Bilge Pump Control
Chemical Batching

LIQUID LEVEL CONTROL SERIES

AMETEK NCC Liquid Level Controls are reliable and accurate controls that are designed
to detect and control levels of electrically conductive liquids within a range of 0 to 250,000
ohms. These resistance sensor controls provide users with the ability to maintain fluid levels in a variety of sophisticated equipment.

2-2

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Single Probe)
05SLA and 05SLB Series
FEATURES

If the tank is non-conductive, a second
(common) probe must be installed at a level
where it will always be submerged.

Solid state sensing circuitry
Single probe level detection
User adjustable sensing resistance
Rugged octal plug-in housing
Heavy duty internal construction
100% functionally tested
File #E61377

SPECIFICATIONS

SENSITIVITY
ADJUST

1K

250K

OHMS

SENSITIVITY ADJUST
ACCESS COVER
3.45 MAX
2.90

NATIONAL CONTROLS
CORPORATION
WEST CHICAGO, IL. 60185

LIQUID LEVEL CONTROL
MODEL: LNC-05SLB-441
1K-250K OHMS
SENSE RANGE:

FILE NO.E61377
FILE NO.LR33434

1.75

6
7

2

2.40

3

Operating Logic: In the Model 05SLA
(Pump Down) the output relay is deactivated
as long as no liquid is in contact with the
probe. As the liquid makes contact with the
probe, a time delay is initiated. At the end
of the time delay, the output relay is activated until the liquid breaks contact with the
probe.
In the Model 05SLB (Pump Up) the output relay is deactivated as long as the liquid
is in contact with the probe. As the liquid
drops away from the probe, a time delay
is initiated. At the end of the time delay,
the output relay is activated until the liquid
touches the probe again.

C
L

4

These controls utilize a single probe input
for maintaining a level of liquid. A built-in
time delay prevents rapid cycling. They are
packaged in a standard octal plug-in housing. The probe and sensing circuit are isolated from line voltage via a transformer. The
probe is driven with an AC signal to prevent
plating. The output is an electro-mechanical
relay rated at 10 A.

CONTROL TYPE
On/Off Resistance Sensing: Probe resistance
above set point activates output relay after a
fixed time delay
Time Delay: 5 sec. ±10%, other delay times
available
Sensing Voltage: 18 VAC, max. RMS
Sensing Current: 2.0 mA, max. RMS
Sensitivity Adjustment: 1K to 250 K ohms ±10%
factory set at 100 K ohms ±10%
INPUT
Operating Voltage: 24, 120 or 230 VAC ±10%
Power Consumption: 1.2 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, SPDT (1 form C)
Rating: 10 A resistive at 120, 240 VAC; 100 mA
at 5 VDC minimum load current
Life:
Mechanical: 5,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 8-pin octal plug
Mounting: Socket mount, part number
MS0-0008P-012
ENVIRONMENTAL
Operating Temperature: -23°C to 55°C

5

●
●
●
●
●
●
●

1

8

ORDERING INFORMATION
LOGIC TYPE

INPUT VOLTAGE

05SLA - Pump Down

24 VAC

—

05SLA - Pump Down

120 VAC

LNC-05SLA-441

05SLA - Pump Down

230 VAC

—

05SLB - Pump Up

24 VAC

LNC-05SLB-447

05SLB - Pump Up

120 VAC

LNC-05SLB-441

05SLB - Pump Up

230 VAC

LNC-05SLB-445

ACCESSORY

PART NUMBER

4

PART NUMBER
3

5

COMMON

6

PROBE
N.C.

2

7
1

8

INPUT
VOLTAGE

Probe Holder with Ground

LLH-11383-010

PIN CONFIGURATION

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

DWG\4787/9/93

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body
Octal Socket, Back Panel Mount
Hold Down Strap for Control

LLP-001/2-011
MSO-0008P-012
ASY-STRAP-7.00L

Consult factory for any special requirements not
listed in catalog (minimum order requirement may
apply).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

LIQUID LEVEL CONTROL SERIES

2-3

Resistance Sensors (Dual Probe)
DLA and DLB Series
FEATURES

SPECIFICATIONS

●
●
●
●
●
●

CONTROL TYPE
On/Off Resistance Sensing:
DLA Models: Probe resistance below set point
activates relay
DLB Models: Probe resistance above set point
activates relay
Sensing Voltage: 18 VAC, max. RMS
Sensing Current: 2.0 mA, max. RMS
Sensitivity Adjustment: 1K to 250 K ohms
±10%, factory set at 100k ohms ±10%
INPUT
Operating Voltage: 24, 120 or 230 VAC, ±10%
Power Consumption: 1.2 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, SPDT (1 form C)
Rating: 10 A resistive at 120, 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 5,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 8-pin octal plug
Mounting: Socket mount, part number
MS0-0008P-012
ENVIRONMENTAL
Operating Temperature: -23°C to 55°C

Solid state sensing circuitry
Dual probe level detection
User adjustable sensing resistance
Rugged octal plug-in housing
Heavy duty internal construction
File #E61377

This family of Level Controls provides high
and low level sensing with Pump Up or
Pump Down capabilities. They are packaged in a standard octal plug-in housing.
The probe and sensing circuit are isolated
from line voltage via a transformer. The
probe is driven with an AC signal to prevent
plating. The output is an electro-mechanical
relay rated at 10 A.
Operating Logic: In the Model DLA (Pump
Down) the output relay is activated when
the upper probe detects the presence of liquid and it remains activated until the lower
probe detects the absence of liquid.
In the Model DLB (Pump Up) the output relay is activated when the lower probe
detects the absence of liquid and it remains
activated until the upper probe detects the
liquid.
If the tank is non-conductive, a third
(common) probe must be installed at a level
where it will always be submerged.

C
L

SENSITIVITY
ADJUST

1K

250K

OHMS

SENSITIVITY ADJUST
ACCESS COVER
3.45 MAX
2.90

NATIONAL CONTROLS
CORPORATION
WEST CHICAGO, IL. 60185

LIQUID LEVEL CONTROL
MODEL:
LNC-00DLA-441
SENSE RANGE:
1K-250K OHMS

FILE NO.E61377
FILE NO.LR33434

1.75

6

2.40

4

5

2

7

3

1

8

ORDERING INFORMATION
LOGIC TYPE
DLA - Pump Down

INPUT VOLTAGE

PART NUMBER

24 VAC

LNC-00DLA-447

DLA - Pump Down

120 VAC

LNC-00DLA-441

DLA - Pump Down

230 VAC

LNC-00DLA-445

DLB - Pump Up

24 VAC

LNC-00DLB-447

DLB - Pump Up

120 VAC

LNC-00DLB-441

DLB - Pump Up

230 VAC

LNC-00DLB-445

ACCESSORY

PART NUMBER

Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body
Octal Socket, Back Panel Mount
Hold Down Strap for Control

4
3

PROBE COM

5

6

2

LOW
PROBE
HI
PROBE

7
1

8

INPUT
VOLTAGE

PIN CONFIGURATION
DWG\4787/9/93

LLP-001/2-011
MSO-0008P-012
ASY-STRAP-7.00L

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-4

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Dual Probe)

Models NS127, NS128 and NS143

ORDERING INFORMATION
LOGIC TYPE

INPUT VOLTAGE

PART NUMBER

Pump Down

120 VAC

LNC-NS127-120

Pump Down

240 VAC

LNC-NS127-240

Pump Up

120 VAC

LNC-NS128-120

Pump Up

240 VAC

LNC-NS128-240

Pump Up

120 VAC

LNC-NS143-120

Pump Up

240 VAC

LNC-NS143-240

ACCESSORY

4.00
3.62
To probes
and tank

.44

N.O. N.C. COM

L1

3.00

H C

2.12

L

.19

L2

Isolated relay
output

Input
Voltage
(4) .14 Dia Mounting holes

(3672-6)

(2) .187 Dia.
Mounting holes

NS143

.19

1.56

3.12

2.12
2.50

Operating Logic: In the Model NS127
Pump Down) the output relay is de-energized until the liquid reaches the high probe.
When liquid touches the high probe, the
output relay is activated until the level drops
below the low probe.
In Models NS128 and NS143 (Pump Up)
the output relay is energized until the liquid reaches the high probe. When the liquid
touches the high probe, the output relay is
deactivated until the level drops below the
low probe.
If the tank is non-conductive, a third
(common) probe must be installed at a level
where it will always be submerged.

NS127, NS128

PROBES

L

L2 L1 N.O.

LOAD

CONTROL TYPE
On/Off Resistance Sensing:
NS127: Probe resistance below set point activates relay
NS128 and NS143: Probe resistance above set
point activates relay
Sensing Voltage: 15 VAC, max. RMS
Sensing Current: 2 mA, max. RMS
Sensitivity Adjustment:
NS127 and NS128: Factory set at 100k ohms
±10%
NS143: Factory set at 50 K ohms ±10%
OUTPUT
Type:
NS127 and NS128: Isolated relay contacts, SPDT
(1 Form C)
NS143: Relay contact SPST-NO switches L1 to
normally open terminals
Rating:
NS127 and NS128: 10 A resistive at 120 VAC, 5 A
resistive at 240 VAC
NS143: 5 A resistive at 120, 240 VAC, 100 mA at
5 VDC minimum load current
Life:
Mechanical:
NS143: 5,000,000 cycles
NS127, NS128: 10,000,000
Electrical: 100,000 min. at full load
INPUT
Operating Voltage: 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons
Mounting:
NS127 and NS128: 4 -.141” dia. mounting holes
NS143: 2 -.187” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: -20°C to 55°C

100% functionally tested
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
●
File #E61377 Model NS127
and NS128 only

Input
Voltage

H C

To Probes
and Tank

2.00

SPECIFICATIONS

●
●
●
●

1.50

FEATURES

(3672-3)

To Level Control
L H
C

To
. conductive tank
High Probe
Low Probe
Typical Probe Connection

PART NUMBER

Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body

LLP-001/2-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-5

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Pump Up Logic with Heater Burn Out Protection)
Models NS210 and NS211

1.75 max.

NS210

C

Fill

4.50
.25

3.50

(3672-1)

4.00
3.50

NS211

2.50
3.00

FILL

.25

HEAT FILL L1

HEAT

.25

4.00

(5) .14 Dia
Mounting Holes

L2

Input
Voltage

5.00

H

Heat

L

2.25

Low
Light

To Probes
and Tank

1.25

Input
Voltage

FILL

Operating Logic: Assuming an empty tank,
upon application of voltage to the system,
the fill output is turned on and the heater output is off. As the liquid fills the tank,
and when it reaches the low probe (above
heater), the heater output is turned on. The
level will rise until it reaches the high probe
causing the fill output to turn off. As liquid
is removed from the tank, 2 to 4 seconds
after it breaks contact with the high probe,
the fill output is turned on and stays on until
the liquid reaches the high probe. This time
delay eliminates fill output chatter if the liquid is splashing.
If the tank is non-conductive, a third
(common) probe must be installed at a level
where it will always be submerged.

LOW
LIGHT HEAT

CONTROL TYPE
On/Off Resistance Sensing:
On low probe: probe resistance below set
point activates heater output
On high probe: probe resistance above set
point activates fill output after a 2 to 4 sec.
delay
Sensing Voltage: 15 VAC, max. RMS
Sensing Current: 2 mA, max. RMS
Sensitivity Adjustment: Factory set at
50 K ohms ±10%
INPUT
Operating Voltage: 24, 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, switch loads to L1
Rating: 5 A resistive at 240 VAC
Life:
Mechanical: 5,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons
Mounting: 4 - .141” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: 0°C to 55°C

100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
●
File #E61377

L1

SPECIFICATIONS

●
●
●
●
●

L2

FEATURES

PROBES

H C

1.75
Max.

To Probes
and Tank

(3672-2)

.25

L

(4) .14 Dia
Mounting Holes

To Level Contro
l
L H
C

Heating
Element

To conductive
tank
High Probe
Low Probe

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

Pump Up

LOGIC TYPE

24 VAC

LNC-NS210-024

Pump Up

120 VAC

LNC-NS210-120

Pump Up

240 VAC

LNC-NS210-240

Pump Up

120 VAC

LNC-NS211-120

ACCESSORY

Typical Probe Connection

PART NUMBER

Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body

LLP-001/2-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-6

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Dual Probe)

(3673-1)

NS129, NS132
4.00
3.62

.19

To probes
and tank

Increase
.44

Sens.
Adjust

L

H

C

L1

L2

N.C. N.O. COM.

(4) .14 Dia
Mounting Holes

Isolated Relay Input
Output
Voltage

NS139
5.00
4.62
Input
Isolated Relay Voltage
Output

.19

.19

N.C. N.O. COM.

L1 L2

H

Increase

C

3.00

L

2.62

Operating Logic: In Models NS129 and
NS139 (Pump Down) the output relay is deenergized until the liquid reaches the high
probe. When liquid touches the high probe,
the output relay is activated until the level
drops below the low probe.
In Models NS132 (Pump Up) the output
relay is energized until the liquid reaches
the high probe. When the liquid touches the
high probe, the output relay is deactivated
until the level drops below the low probe.
If the tank is non-conductive, a third
(common) probe must be installed at a level
where it will always be submerged.

2.12

CONTROL TYPE
On/Off Resistance Sensing:
NS129 and NS139: Probe resistance below set
point activates relay
NS132: Probe resistance above set point activates relay
Sensing Voltage: 15 VAC, max. RMS
Sensing Current: 2.0 mA, max. RMS
Sensitivity Adjustment: Adjustable by a Trimpot
from .1-100 K ohms +10%, -0%
INPUT
Operating Voltage: 120, 240 VAC, ±10%
Power Consumption: 11 VA max. for 120 VAC
units
Frequency: 50/60 Hz
OUTPUT
Type:
NS129 and NS132: Relay contacts SPDT
(1 Form C)
NS139: Relay contacts DPDT (2 Form C)
Rating: 10 A resistive at 120 VAC; 5 A resistive at
240 VAC; 100 mA at 5 VDC min. load current
Life:
Mechanical: 10,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: Terminal blocks with #6 screw
connections
Mounting: 4-.141” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: -20°C to 55°C

100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
Adjustable sensitivity by Trimpot
#6 screw terminal connections
Conformal coating to protect circuit
from harsh environments
●
File #E61377

3.00

SPECIFICATIONS

●
●
●
●
●
●

To probes
and tank

FEATURES

1.75

Models NS129, NS132 and NS139

Sens.
Adjust

N.C. N.O. COM.

Isolated Relay
Output

1.75

(4) .14 Dia
Mounting holes

(3673-2)

ORDERING INFORMATION
LOGIC TYPE

To Level Control
L H
C

INPUT VOLTAGE

PART NUMBER

Pump Down

120 VAC

LNC-NS129-120

Pump Down

240 VAC

LNC-NS129-240

Pump Down

120 VAC

LNC-NS139-120

Pump Up

120 VAC

LNC-NS132-120

Pump Up

240 VAC

LNC-NS132-240

ACCESSORY

To
. conductive tank
High Probe
Low Probe
Typical Probe Connection

PART NUMBER

Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body

LLP-001/2-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-7

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Dual Probe, Dual Logic)

PROTECTION
Isolation: 1500 VAC between probe and other
terminals
Transient Voltage: Protected by 30 joule metal
oxide varistor
Coating: Conformally coated with RTV to protect
against moisture
MECHANICAL
Terminations: #8 screw for input voltage, .25” x
.032” fast-ons for load, .187” x .020” fast-ons for
probes
Mounting: 2-3/16” slots on 3.5” center in aluminum chassis
ENVIRONMENTAL
Operating Temperature: -20°C to 55°C

Program Wire

C
L

B A

C
H
L

4.00

Note: Contact factory for higher rating requirements.

2.81

3.50
(MOUNTING C/C)

Operating Logic: By switching a program
wire from position A to B, the user can
select either pump down (Mode A), or pump
up (Mode B) logic.
In Mode A, the load is de-energized until
the liquid reaches the high probe. When liquid touches the high probe, the load is activated until the level drops below the low
probe.
In Mode B, the load is energized until the
liquid reaches the high probe. When liquid
reaches the high probe, the load is deactivated until the level drops below the low
probe.
If the tank is non-conductive, a third
(common) probe must be installed at a level
where it will always be submerged.

LOAD

CONTROL TYPE
On/Off Resistance Sensing:
Mode A: Probe resistance below set point activates load
Mode B: Probe resistance above set point activates load.
Sensing Voltage: 30 VAC, max. RMS
Sensing Current: 1 mA, max. RMS
Sensitivity Adjustment: Factory set at
50 K ohms ±20%
INPUT
Operating Voltage: 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Single pole solid state switch
Rating: 7.5 A resistive at 120, 240 VAC; 1/3 hp
rated at 120, 240 VAC
Life:
Electrical: 1,000,000 min. at full load

100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
Selectable logic
Conformal coating to protect circuit
from harsh environments
●
File #E61377

1.87

SPECIFICATIONS

●
●
●
●
●

To Probes
and Tank

FEATURES

Aluminum
Chassis

Model NS146

L2

L1

.187

Mounting Slots
2 places

Input Voltage

To Level Control
L H

C
(3672-4)

To. conductive tank
High Probe
Low Probe

Typical Probe Connection

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

Pump Down/Pump Up

LOGIC TYPE

120 VAC

LNC-NS146-120

Pump Down/Pump Up

240 VAC

LNC-NS146-240

PART NUMBER

Program wire selects Pump Down Mode A
or Pump Up Mode B.

ACCESSORY
Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body

LLP-001/2-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-8

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Dual Probe, Dual Voltage) 1hp Solid State Output
Model NS141

240 V

120 V

LOAD

COM

LOAD

075

COM

120V

240V

120 VAC
240 VAC

INPUT VOLTAGE
NOTE: MUST USE COM TO 120V
OUTPUT WHEN 120V INPUT IS USED
MUST USE COM TO 240 V OUTPUT
WHEN 240 V INPUT IS USED

.187 X .020 MALE
FAST-ON (3 PL)
2.80

IDLE
(RED LED)

1.40

075

HI

12

075

COM

LOAD

120 V
R

6" X 6" HEATSINK

240 V

075

4

E61377

10" X 10" HEATSINK

R

12" X 12" HEATSINK

075

LNC-NS141-*10

075

8

3.50

075

4.00

LO

LOAD CURRENT (AMPS RMS)

COM

CONTROL TYPE
On/Off Resistance Sensing:
NS141-A10/A100: Probe resistance below set
point activates relay
NS141-B10/B100: Probe resistance above set
point activates relay
Sensing Voltage: 30 VAC, max. RMS
Sensing Current: 1 mA, max. RMS
Sensitivity Adjustment: Factory set at
50 K ohms, ±20%

LO

16

SPECIFICATIONS

075

075

HI

Operating Logic: In Model NS141-A10
(Pump Down) the load is de-energized until
the liquid reaches the high probe. When liquid touches the high probe, the load is activated until the level drops below the low
probe.
Model NS141-B10 (Pump Up): The load
is energized until the liquid reaches the high
probe. When liquid touches the high probe,
the load is deactivated until the level drops
below the low probe.
On both models a red light is activated
when the load is off. If the tank is non-conductive, a third (common) probe must be
installed at a level where it will always be
submerged.

COM

voltages
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
Adjustable sensitivity by Trimpot
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
●
File #E61377

●
●
●
●
●

OUTPUT
Type: Single-pole solid state switch
Rating: 16 A 1 hp at 120, 240 VAC
Life:
Electrical: 1,000,000 min. at full load
INPUT
Operating Voltage:
NS141-A10: 120 VAC, ±10%, between COM
and 120 terminals
NS141-B10: 240 VAC, ±10%, between COM
and 240 terminals
NS141-A100: 100 VAC, ±10%, between COM
and 120 terminals
NS141-B100: 200 VAC, ±10%, between COM
and 240 terminals
Power Consumption:
NS141-A10/B10: 3.0 VA max.
NS141-A100/B100: 4.0 VA max.
Frequency: 50/60 Hz
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
Transient Voltage: Protected by a 30 joule metal
oxide varistor
MECHANICAL
Terminations: 1/4” x .032” male fast-ons for
input voltage and load, .187” x .020” fast-ons for
probes
Mounting: 2 - 3/16” slots on 3.5” center in aluminum chassis
ENVIRONMENTAL
Operating Temperature: 0°C to 65°C

A B

● 100% functionally tested
● 16 A 1 hp solid state output rating
● 120/240, 100/200 VAC operation

.250

FEATURES

NO HEATSINK
COM

120V

240V

0
68 (20)

104 (40)

140 (60)

AMBIENT TEMPERATURE

176 (80)

.250 X .032 MALE
FAST-ON (6 PL)

F ( C)

MAXIMUM LOAD VS. AMBIENT

LOGIC TYPE
Pump Down

INPUT VOLTAGE

PART NUMBER

120/240 VAC

LNC-NS141-A10

Pump Up

120/240 VAC

LNC-NS141-B10

Pump Down

100/200 VAC

LNC-NS141-A100

Pump Up

100/200 VAC

LNC-NS141-B100

ACCESSORY

PART NUMBER

Probe Holder with Ground

LLH-11383-010

.10

ORDERING INFORMATION

.312

1.70 MAX

4608/12/94

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-9

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Single Probe, Pump Up Logic with Time Delayed Output)
Models NS156 and NS159
FEATURES

SPECIFICATIONS

●
●
●
●
●

CONTROL TYPE
On/Off Resistance Sensing: Probe resistance
above set point activates fill output after a
fixed time delay
Sensing Voltage: 15 VAC, max. RMS
Sensing Current: 2 mA, max. RMS
Sensitivity Adjustment:
NS156: Factory set at 100 K ohms ±10%
NS159: Factory set at 500 K ohms ±10%
Activate Time Delay:
NS156: 5 sec. ±1 sec.
NS159: 1 sec. ±.5 sec.
Fault Timer Delay, NS159: 300 sec. ±15%

1.40

Contact factory for other sensitivity and time delay requirements.

INPUT
Operating Voltage: 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
OUTPUT
Type:
NS156: Solid state switch, .75 A at 25°C, .34 A
at 77°C
NS159: Relay contact, 2 A at 120 VAC
Life:
NS156: 1,000,000 cycles min. at full load
NS159: 300,000 cycles min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
Transient Voltage: Protected by 30 joule metal
oxide varistor
Coating: Conformally coated with RTV to protect
against moisture
MECHANICAL
Terminations: 1/4” x .032” fast-ons
Mounting: 2 -.218” dia. holes
ENVIRONMENTAL
Operating Temperature:
NS156: +5°C to 77°C
NS159: +5°C to 65°C

Mounting Bracket
by Customer

.25

Operating Logic: As liquid is removed from
a tank and contact with a probe is interrupted, a fixed time delay is started. At the end
of the time delay, the output is activated
until the level rises and contacts the probe.
On Model NS159, when the output is
turned on, a fault timer is started. If the output is still on at the end of the fault time, the
fault timer will shut the output off until voltage is removed and re-applied to the control system. The purpose of the fault timer is
to eliminate overflow due to an open probe.
If the tank is non-conductive, a second
(common) probe must be installed at a level
where it will always be submerged.

1.22

2.75
1.12

.37

.22 Dia.
Mounting
Holes
2 places
Probe
Common

Probe
Com

Probe
Common
Terminal
3.50

100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
●
File #E61377

P

To Probe

L2
L1
Load

WATER
SOLENOID

NS156
(3673-3)

To Level Control
P
Com

Input
Voltage

To Conductive
Tank
Probe

Typical Probe Connection

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

Pump Up

LOGIC TYPE

120 VAC

LNC-NS156-120

Pump Up

240 VAC

LNC-NS156-240

Pump Up/Fault Timer

120 VAC

LNC-NS159-120

ACCESSORY

PART NUMBER

Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body

LLP-001/2-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-10

LIQUID LEVEL CONTROL SERIES

Resistance Sensors (Low Water Detect Logic)
Model NS157

240 V

120 V

LOAD

COM

LOAD

075

COM

120V

240V

120 VAC
240 VAC

INPUT VOLTAGE
NOTE: MUST USE COM TO 120V
OUTPUT WHEN 120V INPUT IS USED
MUST USE COM TO 240 V OUTPUT
WHEN 240 V INPUT IS USED

.187 X .020 MALE
FAST-ON (3 PL)
2.80

IDLE
(RED LED)

1.40
A B

.250

Operating Logic: The output relay is activated when liquid touches the probe. As the
liquid level drops below the probe, the relay
is deactivated.
If the tank is non-conductive, a second
(common) probe must be installed at a level
where it will always be submerged.

LO

CONTROL TYPE
On/Off Resistance Sensing: Probe resistance
below set point activates output relay
Sensing Voltage: 20 VAC, max. RMS
Sensing Circuit: 2 mA, max. RMS
Sensitivity Adjustment: Factory set at
50 K ohms ±10%
INPUT
Operating Voltage: 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: SPDT relay, isolated contacts
Rating: 5 A resistive at 120 VAC 100 mA at
5 VDC min. load current
Life:
Mechanical: 2,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons
Mounting: 4 -.141” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: 0°C to 70°C

100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
●
File #E61377

HI

SPECIFICATIONS

●
●
●
●
●

COM

FEATURES

COM
HI
240 V

R

120 V

E61377

LOAD

COM

120V

R

LNC-NS141-*10

3.50

4.00

LO

COM

240V

INPUT VOLTAGE

PART NUMBER

Low Water Detect

LOGIC TYPE

120 VAC

LNC-NS157-120

Low Water Detect

240 VAC

LNC-NS157-240

ACCESSORY

.10

ORDERING INFORMATION

.312

1.70 MAX

.250 X .032 MALE
FAST-ON (6 PL)

PART NUMBER

Probe Holder with Ground

LLH-11383-010

Probe, 6” Long, 1/4” Dia., S.S.

LLP-06.00-OSS

Probe, 12” Long, 1/4” Dia., S.S.

LLP-12.00-OSS

Probe, 24” Long, 1/4” Dia., S.S.

LLP-24.00-OSS

Probe Assembly, Plastic Body

LLP-001/2-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

2-11

LIQUID LEVEL CONTROL ACCESSORIES
1.575

.866

.315

.709

Socket
MSO-0008P-012

4

3

7

8

1

2

.984

8-pin Circular Socket, DIN Rail
Mountable

5

Mounting Holes
.165 dia. 2 pl.

165 dia.

2.362

ORDERING INFORMATION

6

1.299

1.299

Probe Holder

TERMINAL NUT

Metal parts are 300 series non-magnetic
stainless steel. These internally conductive
glass-seal probe holders will withstand up to
2500 psi or 700°F.
The probe holders are rated at 250 V and can
be used in steam applications up to 250 psi.

STAINLESS STEEL SHELL

TERMINAL NUT
8 - 32 NC - 2 THREAD
2 PLACES

3/8 x18 DRYSEAL TAPER
PIPE TREAD (SAE SHORT)
AL2 O3
INSULATOR

13/16
HEX

.410 dia.

.531 dia.
GLASS SEAL

ORDERING INFORMATION
Probe Holder with Ground

S.S. CONNECTOR
NUT
.687

1.250

.360

.718

1/4 - 20 NC 2
11/32 FULL THREAD
.687

.437

3/8
HEX

.625

LLH-11383-010
3.3 26 REF .

Probes
ORDERING INFORMATION
Stainless Steel 6” Probe

LLP-06.00-OSS

Stainless Steel 12” Probe

LLP-12.00-OSS

Stainless Steel 24” Probe

LLP-24.00-OSS

L– 1/8

1/2–1/8

1/4 dia.
CHAMFER 1/32 x 45
¦

Hold-down Strap

7.00

.33
.45

ORDERING INFORMATION
Hold-down Strap for Plug-In Level
Sensors

ASY-STRAP-7.00L
.065 ± .015

ULTEM PLASTIC
BODY

Button Probe

.50 x 20 THREAD

STAINLESS STEEL
PROBE

#8 - 32 THREAD
TERMINAL

LLP-001/2-011

.875

.750

.1.00 .dia.

ORDERING INFORMATION
Button Probe

’O’ RING SEAL

.30 MAX.

.45
1.50 MAX.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

Notes

3-1

AMETEK NCC offers impressive factory backup support and our parts inventory and product availability is unsurpassed. With over 250
stocking distributor outlets, serious downtime
problems can virtually be eliminated. Technical
assistance for design and engineering help is
readily available through our toll free number:
800-323-2593.

Common Applications:
●
●
●
●
●
●
●
●
●
●
●
●

Walk-in Refrigerators
Coolers/Freezers
Food Warmers
Convection Ovens
Testing Chambers/Ovens
Dry Cleaning Machinery
Testing (Brew Temperature)
Commercial Dishwashers
Coffee Urns
Heating and Air Conditioning Testing
Kitchen Grease Filters
Heat Sensitive Equipment

TEMPERATURE MONITORS/CONTROLS

AMETEK NCC Digital Temperature Indicators,
Controllers and Timers allow the constant
monitoring of temperature for various equipment applications. These controls are built
to withstand rugged environments and still
remain accurate, providing a high level of
quality performance.

3-2

TEMPERATURE MONITORS/CONTROLS

Digital Temperature Controller
TC140 Series
FEATURES
●
●
●
●
●
●
●
●
●
●
●
●
●
●

Compact design
Easy-to-read 4-digit LED display
Time displays in hr./min.
Temperature display in Fahrenheit or
Celsius
Non-volatile storage of programmed
parameters
Watchdog timer ensures reliability
4-button, moisture-resistant keyboard
using snap-action sealed switches
Diagnostic messages for fault conditions
Front panel keyboard programming of
time and temperature
HEAT ON indicator
Accurate and durable thermocouple
temperature sensing
Convenient operating voltage ranges
Heavy duty stainless steel front panel
File #E104595

The Model TC140 is a Digital Temperature
Controller which features an independent
count-up timer. The controller uses a Type
K thermocouple and is microprocessor controlled. The regulation temperature can be
set in one degree increments within specified limits. Hysteresis, Offset and Fahrenheit
or Celsius are selected via front panel
switches. The HEAT ON light indicates output relay activation. Actual sensed temperature is normally shown on the digital display.
The control has diagnostic messages for
open probe and memory failure.
Operating Logic: The timer function is
started by pressing the TIME START button. The digital display will then alternate
between probe temperature and elapsed
time in hours and minutes. The timer function is cancelled by pressing the TIME
START button again.
Setting Regulation Point: Press the TEMP
button momentarily. The display will flash
SET and PNT briefly then flash the setpoint
value. The  and  buttons can now be
used to adjust the temperature regulating
setpoint. Press the TEMP button again to
cause the control to regulate to the new setpoint.
Setting Hysteresis: The turn-on and turnoff temperature around a setpoint can be

separately adjusted to ±20°F. Press and
hold the ,  and TEMP buttons for .5 second. The display will alternate between ON
and the turn-on value. The  and  buttons can now be used to change this value.
Press the TEMP button again and the OFF
value will be displayed. The  and  buttons can now be used to change the OFF
value. Pressing the TEMP button again will
return the control to normal operation and
will store the new settings. The hysteresis
is set to -1°F, +0°F as shipped from the
factory.
Setting Offset: The displayed value can be
changed by ±20°F relative to actual sensed
temperature value. This feature corrects for
disparity of location of the probe and the
volumetric center of the heating chamber.
Press and hold the TIME and TEMP buttons, then also press and hold the  and
 buttons. After one second the display
will flash OFF and SET briefly then will flash
the offset value. At this point, the  and 
buttons can be used to adjust the offset.
Pressing the TEMP button programs the
control for the new value. The offset is set
to 0 as shipped from the factory.

Diagnostic Messages: An open
probe will cause the digital display to show PROB and will disable the output until input voltage
is removed and re-applied. If a
memory loss or failure occurs, the
digital display will show FAIL and
the output will be disabled. Input
voltage should be removed and
re-applied. If the FAIL message is
gone, recheck programmed parameters and resume operation. If the
FAIL message reappears, contact
the factory for service.

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

18 to 28 VAC

TNC-TC140-A010

90 to 135 VAC

TNC-TC140-A120

198 to 242 VAC

TNC-TC140-A220

ACCESSORY

PART NUMBER

Type K Thermocouple, Bead Tip Probe, 6’

ASP-CH/AL-011

Type K Thermocouple, Perforated Probe, 24”

ASP-CH/AL-013

Type K Thermocouple, Probe with 6’ Lead

ASP-CH/AL-016

Type Ke Thermocouple, Probe with 10’ Lead

ASP-CH/AL-017

Type K Thermocouple, Perforated Probe, 48”

ASP-CH/AL-018

Type K Thermocouple, Perforated Probe, 72”

ASP-CH/AL-019

Type K Thermocouple, Probe with Flange

ASP-CH/AL-020

Type K Thermocouple, Ring Lug Mount

ASP-CH/AL-021

*All transformer wires are 8” long: 120V Primary Black/White; 220V Primary Black/Black

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TEMPERATURE MONITORS/CONTROLS

SPECIFICATIONS

3.12
Degree Indicator

TEMPERATURE
TIME-HRS:MIN

4.1
3.5

HEAT
ON
TIME
START
STOP

TEMP

TEMPERATURE
CONTROLLER/CLOCK

.187 Dia.
2 Holes

1.8
3.6

Provide tapped hole
for #8-32 screw
(2 Pl.)

3.5
3.187

3.25

RED YEL
(-) (+) XFMR

.15

1.40

To Temp.
Probe Type K
Thermocouple

24VAC
Input
Voltage

.094 R
Max. Typ.

C
L

1.75
1.593

(1870-1)

3.12

C
L

N.O.

1.687
3.375

Output Contacts
1AMP, 12-250VAC

PANEL CUTOUT

TNC-TC140-010

3.0 Max.
1.70

120 or 220 VAC
Input

3.250

8"

3.125

CONTROL/TIMING
Temperature Control Mode: ON/OFF with hysteresis
Temperature Sensor: Type K thermocouple with
special limits of error is recommended for max.
accuracy
Maximum Timing Interval: 99 hr.: 99 min.
Minimum Timing Accuracy: ±.2%
INPUT
Operating Voltage:
TNC-TC140-010: 18-28 VAC, 60Hz
TNC-TC140-120: 95-135 VAC, 60Hz
TNC-TC140-220: 198-242 VAC, 60Hz
Power Consumption:
TNC-TC140-010: 10 VA max.
TNC-TC140-120/220: 30 VA max.
Resolution: ±1°F
Temperature Sensing Range: 50°F to 700°F
(10°C to 371°C)
Temperature Range Display Accuracy: ±5.4°F
(±3.0°C) max. over operating voltage and ambient
temperature range
Temperature Regulating Range: 100°F to 601°F
(38°C to 316°C)
Selecting for °F or °C: Press and hold both 
and  buttons until temperature scale changes;
release buttons
OUTPUT
Heater Output Rating: SPST normally open isolated contact 1 A at 24 to 250 VAC
ENVIRONMENTAL
Ambient Operating Range: 5°C to 65°C
Ambient Storage Range: -40°C to 85°C
MECHANICAL
Termination Type: Input voltage and heater output contacts 1/4” x .032” PC mount fast-ons
Probe: #6 screw with clamp
Mounting: Two center mountings (.187 dia.)
Front Panel Material: 18 gauge stainless steel
Keyboard: 4-button moisture resistant using
snap action sealed switches behind a polyester
graphic overlay for maximum reliability
Display: 4-digit, seven segment red LED
Digit Height: .56 inches
ELECTRICAL
Simple wire hook-up

3-3

.150
(1870-2)

To Temp.
Probe Type K
Thermocouple

RED YEL
(-) (+) XFMR

N.O.

Output Contacts
1AMP, 12-250VAC

TNC-TC140-120 AND TNC-TC140-220

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-4

TEMPERATURE MONITORS/CONTROLS

Digital Temperature Controller
TC142 Series
FEATURES
● Compact design
● Easy-to-read 4-digit LED display
● Temperature display in Fahrenheit or
Celsius

● Non-volatile storage of programmed
parameters

● Watchdog timer ensures reliability
● 4-button, moisture-resistant keyboard
using snap-action sealed switches

● Diagnostic messages for fault conditions

● Front panel keyboard programming of
time and temperature

● HEAT ON indicator
● Accurate and durable thermocouple
temperature sensing

● Convenient operating voltage ranges
● Heavy duty stainless steel front panel
●
File #E104595
The Model TC142 is a Digital Temperature
Controller. The controller uses a Type
K thermocouple and is microprocessor
controlled. The regulation temperature can
be set in one degree increments within
specified limits. Hysteresis, Offset and
Fahrenheit or Celsius are selected via front
panel switches. The HEAT ON light indicates
output relay activation. The regulation
temperature is normally shown on the digital
display. To view the sensed temperature,
press the TEMP button. The control has
diagnostic messages for open probe and
memory failure.
Setting Regulation Point: Press the PROG
button momentarily. The display will flash
SET and PNT briefly then flash the setpoint value. The  and  buttons can now
be used to adjust the temperature regulating setpoint. Press the PROG button again
to cause the control to regulate to the new
setpoint. To view or change other functions
while in program mode, press ADV button
to scroll to that function.
Setting Hysteresis: The turn-on and turnoff temperature around a setpoint can be
separately adjusted to ±20°F. Press and
hold the PROG button for .5 second. Scroll
to DEAD BAND using the ADV button. The
display will alternate between ON and the
turn-on value. The  and  buttons can
now be used to change this value. Press the

ADV button again and the OFF value will be
displayed. The  and  buttons can now
be used to change the OFF value. Pressing
the PROG button again will return the control to normal operation and will store the
new settings. The hysteresis is set to -1°F,
+0°F as shipped from the factory.
Setting Offset: The displayed value can be
changed by ±20°F relative to actual sensed
temperature value. This feature corrects for
disparity of location of the probe and the
volumetric center of the heating chamber.
Press and hold the PROG button for .5 second. Scroll to the offset function using the
ADV button. The display will flash OFF and
SET briefly then will flash the offset value.
At this point, the  and  buttons can
be used to adjust the offset. Pressing the
TEMP button programs the control for the
new value. The offset is set to 0 as shipped
from the factory.
Diagnostic Messages: An open probe will
cause the digital display to show PROB and
will disable the output until input voltage is
removed and re-applied. If a memory loss or
failure occurs, the digital display will show
FAIL and the output will be disabled. Input
voltage should be removed and re-applied.
If the FAIL message is gone, recheck programmed parameters and resume operation. If the FAIL message reappears, contact
the factory for service.

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

18 to 28 VAC

TNC-TC142-A010

90 to 135 VAC

TNC-TC142-A120

198 to 242 VAC

TNC-TC142-A220

ACCESSORY
Transformer - 120V, 60Hz Primary

PART NUMBER
B24-NO120-011

Transformer - 240V, 50/60Hz Primary

B24-NO220-011

Type K Thermocouple, Bead Tip Probe, 6’

ASP-CH/AL-011

Type K Thermocouple, Perforated Probe, 24”

ASP-CH/AL-013

Type K Thermocouple, Probe with 6’ Lead

ASP-CH/AL-016

Type Ke Thermocouple, Probe with 10’ Lead

ASP-CH/AL-017

Type K Thermocouple, Perforated Probe, 48”

ASP-CH/AL-018

Type K Thermocouple, Perforated Probe, 72”

ASP-CH/AL-019

Type K Thermocouple, Probe with Flange

ASP-CH/AL-020

Type K Thermocouple, Ring Lug Mount

ASP-CH/AL-021

*All transformer wires are 8” long: 120V Primary Black/White; 220V Primary Black/Black

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TEMPERATURE MONITORS/CONTROLS

SPECIFICATIONS

3.12
Degree Indicator

TEMPERATURE
CONTROLLER

4.1
3.5

HEAT
ON

TEMP

PROG

.187 Dia.
2 Holes

1.8
3.6

Provide tapped hole
for #8-32 screw
(2 Pl.)

3.5
3.187

3.25

RED YEL
(-) (+) XFMR

.15

1.40

To Temp.
Probe Type K
Thermocouple

.094R
Max. Typ.
C
L

1.75
1.593

(3575)

3.12

C
L

N.O.

1.687
3.375

Output Contacts
1AMP, 12-250VAC

24VAC
Input
Voltage

PANEL CUTOUT

TNC-TC142-010

3.0 Max.
1.70

120 or 220 VAC
Input

3.250

8"

3.125

CONTROL/TIMING
Temperature Control Mode: ON/OFF with hysteresis
Temperature Sensor: Type K thermocouple with
special limits of error is recommended for max.
accuracy
Maximum Timing Interval: 99 hr.: 99 min.
Minimum Timing Accuracy: ±.2%
INPUT
Operating Voltage:
TNC-TC142-010: 18-28 VAC, 60Hz
TNC-TC142-120: 95-135 VAC, 60Hz
TNC-TC142-220: 198-242 VAC, 60Hz
Power Consumption:
TNC-TC142-010: 10 VA max.
TNC-TC142-120/220: 30 VA max.
Resolution: ±1°F
Temperature Sensing Range: 50°F to 700°F
(10°C to 371°C)
Temperature Range Display Accuracy: ±5.4°F
(±3.0°C) max. over operating voltage and ambient
temperature range
Temperature Regulating Range: 100°F to 601°F
(38°C to 316°C)
Selecting for °F or °C: Press and hold both 
and  buttons until temperature scale changes;
release buttons
OUTPUT
Heater Output Rating: SPST normally open isolated contact 1A at 24 to 250 VAC
ENVIRONMENTAL
Ambient Operating Range: 5°C to 65°C
Ambient Storage Range: -40°C to 85°C
MECHANICAL
Termination Type: Input voltage and heater output contacts 1/4” x .032” PC mount fast-ons
Probe: #6 screw with clamp
Mounting: Two center mountings (.187 dia.)
Front Panel Material: 18 gauge stainless steel
Keyboard: 4-button moisture resistant using
snap action sealed switches behind a polyester
graphic overlay for max. reliability
Display: 4-digit, seven segment red LED
Digit Height: .56 inches
ELECTRICAL
Simple wire hook-up

3-5

.150
(3574)

To Temp.
Probe Type K
Thermocouple

RED YEL
(-) (+) XFMR

N.O.

Output Contacts
1AMP, 12-250VAC

TNC-TC142-120 AND TNC-TC142-120

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-6

TEMPERATURE MONITORS/CONTROLS

Panel Mount Digital Thermometer
Models TM165 and TM166
FEATURES
● Heavy-duty stainless steel front
●
●
●
●
●
●
●

plate and all metal case for rugged
environments
Easy-to-read digital display
Temperature sensing range of -25ºF to
99ºF (-32ºC to 38ºC)
Front panel selectable ºF to ºC
operation
Alarm temperature setting;
programmable via front panel buttons
Alarm relay
Low voltage AC or DC operation
TM166 fits in a standard electrical box

National Controls’ panel mount thermometer allows the constant monitoring of temperature in critical environments and equipment, enabling a higher degree of operating
efficiency.
The high temperature alarm alerts personnel to a high temperature condition, protecting temperature sensitive equipment and
operations. When the temperature rises to
the setpoint temperature, the display flashes and an audible alarm sounds. When the
temperature falls below the setpoint temperature, the alarm condition ceases. If during the alarm condition, it is desired to turn
off the alarm, depressing the front panel
push-button will interrupt the audible alarm
for approximately 2-1/2 hours, but the display will continue to flash.
The heavy-duty stainless steel front plate
protects the unit from mechanical shock
and abuse, and is designed to blend visually
with other stainless steel equipment.
The thermometer can be mounted directly
on the equipment it is monitoring, or on a
remote panel up to 250 feet away. The thermometer is powered from low-voltage AC or
DC, thus eliminating the high costs of installation to NEC or other high voltage electrical
standard wiring.
The control can also detect an open or
shorted temperature probe. If the probe is
open or shorted the display will show PRB,
the alarm will sound and the relay contacts
will close. The alarm will continue to sound
until the probe error condition is corrected.
In addition, the output relay’s contacts will
close during a high temperature ALARM
condition.

Setting the High Temperature Alarm: On
the front of the TM165 and TM166 there are
up and down arrow buttons for changing
the set point temperature. The set point can
be adjusted to any temperature within the
specified range of that particular model.
Setting ºF or ºC Operation: Using the front
panel buttons the display can be adjusted
to display temperature in ºF or ºC.

SPECIFICATIONS
Temperature Sensing Range: -25ºF to 99ºF
(-32ºC to 38ºC)
Temperature Reading Accuracy: ±3ºF (2ºC)
Resolution: ±1ºF or ºC
Setpoint Range: -15ºF to 50ºF (-26ºC to 10ºC)
Input Voltage: 10.5 to 28 VAC, 50/60 Hz or 12 to
28 VDC
Power Consumption: 5 VA max at 28 VAC
Operating Temperature Range: 0ºC to 65ºC
Output Relay: Form A relay contact, 1 A max. at
30 VAC or DC
Temperature Probe: NTC thermistor, 3000 ohms
at 25ºC, J-Curve

ORDERING INFORMATION
MOUNTING CONFIGURATION

PART NUMBER

Customer Panel Cutout

TNC-TM165-010

Standard Utility Box

TNC-TM166-010

Surface Mount Enclosure for TM165 Only, Single
Surface Mount Enclosure for TM165 Only, Dual
ACCESSORY

TNC-TM165-KTA
TNC-TM165-KT2A
PART NUMBER

6’ Refrigerator / Freezer Probe

ASP-TM165-011

20’ Refrigerator / Freezer Probe

ASP-TM165-012

60’ Refrigerator / Freezer Probe

ASP-TM165-013

Transformer (UL Class II Secondary)

B10-NO120-011

Stainless Steel Enclosure for TNC-TM165-010 Only, Single

BOX-TM100-010

Stainless Steel Enclosure for TNC-TM165-010 Only, Dual

BOX-TM100-020

The TM165 and TM166 panel mount digital thermometers are available in two distinct sizes. When ordering the thermometers,
be sure to select the above depending on your specific application (refer to actual dimensions at right).
Note: The TM165 can be used as a substitute for the TM100 in certain applications.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

TEMPERATURE MONITORS/CONTROLS

3-7

Model TM165
.380
[9.7]

3.120
[79.2]

1.075
[27.31]
MAX.

CL
1.560
[39.6]

.170
[4.32]

2.87
[72.9]
±.06
[1.5]

WIRING DIAGRAM

1.44
[36.6]

INCHES
[mm]
3.87
[98.3]
±.06
[1.5]

5.000
[127]
SEE NOTE 2
16.500
[419.10]
±.500
[12.70]

4.250
[108]

4.25
[108]

N a t i o n a l C o n t r o l s C o r po ra t i o n

.218 [5.54]
DIAMETER
CLEARANCE HOLE
(2 PLACES)

0.250
[6.35]
STRIP
±.062
[1.57]

ORANGE
ORANGE
BLACK
RED

POLYESTER
GRAPHIC
OVERLAY

ALL 22 GA. WIRE

.136 DIA.
#8-32 TAP
(2 PLACES)

ALARM
OUTPUT

SUGGESTED PANEL CUTOUT

ORANGE
10.5 -28 VAC
or
12-28 VDC

.187
[4.75]

ORANGE
RED BLACK

PROBE

Model TM166
2.750
[69.86]

CL

1.375
[34.93]

.170
[4.32]

1.075
[27.31]
MAX.

WIRING DIAGRAM

SEE NOTE 1
1.89 MIN.
[48.0]

1.50 MIN.
[38.1]

82º
INCHES
[mm]

2.250
[57.15]
3.281
[83.34]
CL

4.500
[114.30]

2.85 MIN.
[72.4]

SEE NOTE 2
16.500
[419.10]
±.500
[12.70]

1.641
[41.68]
N a t i o n a l C o nt r o l s C o r p o r a t i o n

82º

.187
[4.75]
DIA. CLEARANCE HOL E
(2 PLACES)

POLYESTER
GRAPHI C
OVERLAY

ORANGE
ORANGE
BLACK
RED
ALL 22 GA. WIRE

NOTES:
1. IF KNOCK-OUTS ARE OFFSET INSIDE THE BOX, THE MINIMUM DIMENSION IS TAKEN
BETWEEN THE INSIDE EDGES OF THE KNOCK-OUTS.
2. DIMENSION SHOWN IS TAKEN FROM THE SURFACE OF THE PRINTED CIRCUIT
BOARD TO THE TIP OF THE WIRE.

0.250
[6.35]
STRIP
±.062
[1.57]

ALARM
OUTPUT

MINIMUM INTERIOR DIMENSIONS
FOR INSTALLATION INTO A STANDARD UTILITY BOX

ORANGE
10.5-28 VAC
or
12-28 VDC

ORANGE
RED BLACK

PROBE

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-8

TEMPERATURE MONITORS/CONTROLS

Digital Temperature Indicator
TM110 Series
FEATURES
Compact design
Easy-to-read red LED digital display
Wide temperature sensing range
Available in °F and °C

This series of temperature indicators provides a reliable, cost efficient way to monitor temperature in critical environments
and equipment. This indicator can be used
on-site or remotely, up to 250 feet from the
probe.
This compact solid state unit features
a large easy-to-read digital display, with
a sensing range of -40°F to 240°F (-40°C
to 115°C) and a calibration set-screw.
Accessories include probes, compression
fittings and transformer. Mounting is by four
corner standoffs. Connections are made
with two probe wires and two input voltage
wires.

3.0

.187

2.625

.187

SPECIFICATIONS
INPUT
Operating Voltage: 12 to 28 VAC or VDC at
250 mA
Frequency: 50/60 Hz
Resolution: ±1°F (±1°C)
Temperature Reading Accuracy: ±2°F (±2°C)
within ±50°F (±30°C) around temperature calibration point
Temperature Reading Range: -40°F (-40°C) to
240°F (115°C)
Ambient Temperature Range: 18°C to 60°C

.437

3.437

.625

1.812

3.062

●
●
●
●

.141 Dia.
4 Holes

Temperature
Calibrate

ORN

ORN

Power

RED

BLK

Probe

(4554-2)

.25
.50

ORDERING INFORMATION
TEMPERATURE RANGE

PART NUMBER

°F Display

TNC-TM110-A10

°C Display

TNC-TM110-A10C

ACCESSORY

PART NUMBER

Refrigerator / Freezer Probe

ASP-TM100-011

Immersion Probe / Stainless Steel

ASP-TM100-012

20’ Refrigerator / Freezer Probe

ASP-TM100-014

60’ Refrigerator / Freezer Probe

ASP-TM100-015

Compression Fitting For ASP-TM100-012

EST-03/16-011

Transformer (120V input - 12V, 5VA output)

B10-NO120-011

Note: The factory can match probe with indicator and calibrate as a set.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-9

TEMPERATURE MONITORS/CONTROLS

Digital Temperature Indicator
TM200 Series
FEATURES

SPECIFICATIONS

● Compact design, will fit into 2” x 4” util-

INPUT
Operating Voltage: 105 to 135 VAC at 50 mA
Frequency: 50/60 Hz
Resolution: ±1°F
Display Accuracy: ±2°F within ±50°F around
known temperature calibration point. Full range
accuracy ±5°F
Sensing Temperature Range: -40°F to 99°F
or °C
Ambient Temperature Range: 0°C to 65°C
PROBE ERROR INDICATION
Shorted Probe: 2 decimal points only displayed
Open Probe: Negative sign and 2 decimal points
only displayed
Out-of-Range Sense Temperature: 2 decimal
points on with digits displayed
MECHANICAL
Mounting: Two faceplate screws (#6-32 x 1/2)
Front Panel Material: 18 gauge stainless steel
Decal Material: Polyester
Digit Height: .56 inches

●
●
●

This series of temperature indicators provides a reliable, cost efficient way to monitor temperature in a variety of environments
and equipment.
These units feature a large red LED display with a sensing range of -40°F to 99°F
or °C, and come with a stainless steel
escutcheon front plate that mounts directly
into a 2” x 4” utility box. To simplify the wiring, the units accept 120 VAC input directly.

Decimal Points
(On for probe
errors)
2.75

Note: Due to non-interchangability of probes, the temperature
indicator must be field calibrated using crushed ice and water
and set to 32°F or 0°C

3.28

●

4.50

●
●
●
●
●

ity box
Easy-to-read led digital display
120 VAC input voltage
Easy field wiring
Stainless steel front panel
Withstands exposure to animal fats and
cleaning agents found in restaurant
environments
Provides diagnostic messages for probe
fault conditions
Smooth, easy-to-clean front decal
Available in °F and °C
File #E104595

DIGITAL
THERMOMETER

#6-32x1/2 Screw
(2 Pl.)

Probe

(1857)

RED

ORDERING INFORMATION

BLK

TEMPERATURE RANGE

PART NUMBER

°F Display

TNC-TM200-120

°C Display

TNC-TM200-120C

ACCESSORY

PART NUMBER

Refrigerator / Freezer Probe

ASP-TM100-011

Immersion Probe / Stainless Steel

ASP-TM100-012

20’ Refrigerator / Freezer Probe

ASP-TM100-014

60’ Refrigerator / Freezer Probe

ASP-TM100-015

2” x 4” Utility Box
Note: The factory can match probe with indicator and calibrate as a set.

BOX-02/04-ELECT

BLU
BLU

Input
120 VAC
Field
Calibration
Adjustment
1.50
Max

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-10

TEMPERATURE MONITORS/CONTROLS

Electronic Temperature Controller
TC280 Series

mechanical thermostats
OFF setpoint adjustment position
Probe failure detect
High current rating
Long contact life

This Controller provides a reliable, cost
effective way to control temperature of heated water within a limited temperature range.
Operating Logic: Upon application of input
voltage, and if the sensed temperature is
below the setpoint, the internal relay will
be activated, turning on the heater load.
The load will stay activated until the sensed
temperature reaches setpoint value. The
setpoint adjustment at the fully counter
clockwise position has an OFF setting that
can be used during equipment set-up to
allow water to fill the vessel before allowing
the heaters to be activated.
Note: The temperature adjustment OFF position is not a mechanical OFF condition, in case of controller failure it may not turn off
the heater load.

1.64

.206

●
●
●
●

.820

.875

CONTROL
Temperature Control Mode: ON/OFF, +2°F to
+4°F hysteresis
Temperature Sensor: Thermistor, ±2% interchangeable within measurement range
Set point Adjustment Range: 175°F ±5°F to
205°F +3°F/-1°F; Fully CCW is in OFF position
Probe Fault Detect: Open or shorted probe will
cause output relay to be deactivated
INPUT
Power Consumption: 5 VA max.
Operating Voltage: 120, 220 VAC ±10%,
50/60 Hz
OUTPUT
Type: Relay contacts, SPST (1 Form A)
Rating: 20 A max. resistive at 120 VAC 10 A max.
resistive at 250 VAC 100 mA at 5 VDC min. load
current
Life: 250,000 cycles min. at full load
Dielectric Breakdown: 2500 VAC RMS, between
probe terminals and input terminals
MECHANICAL
Termination: L1 and HTR #8 screw with clamp;
L2 white -12” long - 22 AWG wire terminated with
1/4 inch female and 1/4” male piggy back pushon terminal
Probe: Screw type caged terminal block
ENVIRONMENTAL
Ambient Operating Range: 0°C to 60°C

1.75

SPECIFICATIONS

●
File #E104595
● Long term setpoint stability
● Close temperature control
● Footprint compatible with electro-

4.250

FEATURES

2.275 MAX
.95 MAX
.275

TEMP. ADJUST
SHAFT

6/32 THREADED
STANDOFF (2 PL.),
3/8 IN. MOUNTING
SCREW LENGTH MAX.

POLYPROPYLENE COVER

22AWG WIRE 12 IN. LONG
WITH .250 FEMALE TERMINAL
AND .250 MALE TERMINAL
"PIGGYBACK"

ORDERING INFORMATION
INPUT

PART NUMBER

120 V

TNC-TC280-120

240 V

TNC-TC280-240

ACCESSORY

2 POS.
PROBE
CONNECTOR

PART NUMBER

12” Probe Tube

ASP-TC280-012

14” Probe Tube

ASP-TC280-014

Important Notice: This control should only be used in a system
incorporating an independently operating high temperature limiting
device which will safely disable the heaters, preventing property
damage or bodily injury, in the event of failure, malfunction or normal wear-out of this control.

N
L1

HTR

(4571-6)

#8 SCREW TERMINAL

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-11

TEMPERATURE MONITORS/CONTROLS ACCESSORIES

BLK

10V

C
L

.750
1.375

.50

R

5VA

YEL

2.65

.187 DIAMETER HOLE
2 PLACES

YEL

2.812

12" LEADS (2)

3.250
1.906

WHITE

1.640

2.265

Transformers

BLACK

ORDERING INFORMATION
B10-NO120-011

120 to 12 VAC, 5 VA, 50/60 Hz

B12-NO120-015

120 to 24 VAC, 5 VA, 50/60 Hz

B24-NO120-011

240 to 24 VAC, 10 VA, 50/60 Hz

B24-NO220-011

YEL

(4572-4)

B10-N0120-011

YEL

(4572-2)

B12-N0120-015

BLK

8" LEADS
4 PLACES

WHT

BLK

BLK

YEL

YEL

YEL YEL

.187 DIAMETER HOLE
2 PLACES

2.812
3.250
1.906

1.640
YEL

YEL

B24-NO220-011

B24-N0120-011

The temperature probes listed can only
be used on TNC-TM100 (discontinued),
TNC-TM110, and TNC-TM200 Series
temperature indicators.

22GA WIRE
1 RED JACKET
1 BLACK JACKET

Refrigerator / Freezer Probe

ASP-TM100-011

Immersion Probe / Stainless Steel

ASP-TM100-012

20’ Refrigerator / Freezer Probe

ASP-TM100-014

60’ Refrigerator / Freezer Probe

ASP-TM100-015

.195 DIA.

1/8" NPT

.435

.375

1.5
.125
(4571-9)

ORDERING INFORMATION

YEL

(4572-3)

(4572-1)

Probes

.187 DIAMETER HOLE
2 PLACES

2.812
3.250
1.906

1.640
YEL

8" LEADS
4 PLACES

.750
1.375

.750
1.375

120 to 10 VAC, 5 VA, 50/60 Hz

Compression Fitting for
ASP-TM100-012

8" LEADS
4 PLACES

WHT

.375

.687

C

2.0

LOAD

.156 DIAMETER HOLE
2 PLACES

.472

.875 – .062

.965

72 - 75.5 INCHES

ASP-TM100-011

EST-03/16-011

4 FOOT, 2 CONDUCTOR CABLE

.187 MAXIMUM

EST-03/16-011

6.00
(4571-3)

ASP-TM100-012

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

1.00

BOX-TM100-010
BOX-TM100-020

4.93

6.00

1.87

.625 TYP.
4 PLCS.

4.00

1.00

.25

1.00

6-32 THREAD HOLE
4 PLACES

BACK

BOX-TM100-010
1.00

7.00.
TOP

2.00

3.50

2.00

.50 DIA. HOLES
3 PLACES

.25

3.75

Stainless Steel Box for One TM165
Stainless Steel Box for Two TM165s

1.44

2.87

8-32 THREAD HOLE
2 PLACES

ORDERING INFORMATION

.375

3.75

4.50

2.12

.187

Boxes

.50 DIA. HOLES
2 PLACES

1.09

1.00

1.00

TEMPERATURE MONITORS/CONTROLS

3.75

3-12

1.75

.187

.625 TYP. 4 PLCS

3.75

6.00

4.93

1.87

.375

4.50

2.12

2.00

2.00

1.75

1.09

6-32 THREAD HOLE
4 PLACES

1.44 typ.
2.87 typ.

8-32 THREAD HOLE
4 PLACES

BACK

BOX-TM100-020

Transducers

.250

The temperature transducers listed can only
be used on TNC-TC280 Series temperature
controllers.

(4571-4)

ORDERING INFORMATION
Temperature Transducer,
8” Stainless Steel

ASP-TC280-011

Temperature Transducer,
12” Stainless Steel

ASP-TC280-012

.250

STAINLESS STEEL TUBE
EPOXY FILLED
8.00" ± .25"
ASP-TC280-011
STAINLESS STEEL TUBE
EPOXY FILLED
12.00" ± .25"
ASP-TC280-012

(4571-7)

24 AWG TEFLON
INSULATED WIRE
18.0" ± .5"
.25 ± .06 STRIP
24 AWG TEFLON
INSULATED WIRE
18.0" ± .5"
.25 ± .06 STRIP

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

3-13

TEMPERATURE MONITORS/CONTROLS ACCESSORIES

Thermocouples

24 GA TEFLON
INSULATED WIRE

The Type K thermocouple probes listed
can only be used on TNC-TC140, and
TNC-TC142 Series temperature controllers.
1.00 – .25

ORDERING INFORMATION
Type K Thermocouple, Bead Tip
Probe, 6’

ASP-CH/AL-011

Type K Thermocouple, Perforated
Probe, 24”

ASP-CH/AL-013

Type K Thermocouple, Probe
with 6’ Lead

ASP-CH/AL-016

Type K Thermocouple, Probe
with 10’ Lead

ASP-CH/AL-017

ASP-CH/AL-011
ASP-CH/AL-012
(4571-5)

ASP-CH/AL-011,012

24 ±1.00

1 ±.125

Type K Thermocouple, Perforated
Probe, 48”

ASP-CH/AL-018

Type K Thermocouple, Perforated
Probe, 72”

ASP-CH/AL-019

Type K Thermocouple, Probe
with Flange

ASP-CH/AL-020

Type K Thermocouple, Ring Lug
Mount

ASP-CH/AL-021

6 FT – 6 IN.
10 FT – 6 IN.

1.750 ±.125

.250
±.062
STRIP

.187
1
±.125

SEE NOTE 2

HEAT SHRINK
TUBING

4-POINT
CRIMP

FIBERGLASS WITH
STAINLESS STEEL
OUTER BRAID

.375

.250

FLATTEN LAST .750
GROUNDED JUNCTION
.140 DIA.

NOTES:

1. TEMPERATURE RATING TO 650˚F
2. TYPE K THERMOCOUPLE, 24 GA. SOLID WIRE, FIBERGLASS INSULATED, SPECIAL LIMITS OF ERROR ±2˚F OR .4% WHICHEVER IS GREATER.
3. ALL DIMENSIONS IN INCHES.
4. REMOVE SHARP EDGES.

STAINLESS STEEL TUBE

24 GA TEFLON
INSULATED WIRE

.250

1.0 – .25
6.00

ASP-CH/AL-016 6 FT – 6 IN.
ASP-CH/AL-017 10 FT – 6 IN.
(4571-2)

ASP-CH/AL-016,017

.750

.187 DIA
(2 PL)

C
L

.375

C
L

1.500

1.00

.375

.050 (18 GA)

.750

3.00

24.0 –.5
2.00

.250 REF.

(4571-12)

ASP-CH/AL-020

24GA THERMOCOUPLE WIRE
L
BRAIDED STAINLESS STEE
PERFORATED STAINLESS STEEL
STEEL TUBING

1.00 – .25
(4571-8)

ASP-CH/AL-013 24" – 1.5
ASP-CH/AL-018 48" – 2
ASP-CH/AL-019 72" – 3

.160 O.D.
MINIMUM

1.125 – .050

ASP-CH/AL-013,018,019

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

Notes

4-1

AMETEK NCC offers impressive factory backup support. Our parts inventory and product
availability is unsurpassed. With over 250
stocking distributor outlets, serious downtime
problems can virtually be eliminated. Technical
assistance for design and engineering help is
readily available through our toll free number:
800-323-2593.

Process Control
Stepping Switch Programming
Solenoid Valve Sequencing
Vacuum Processing
Bottle Filling
Plastic Molding
Vending Machines
Printing Presses
Laundry Equipment
Textile Machinery
Machine Tools
Test Cycling
Food Processing
Water Purification
Copying Machines
Alarm Circuits
Pulse Totalizing
Heat Sealing
Photo Processing
Car Washing
Engine Starting
X-Ray Equipment
Ventilator Controls

DUST COLLECTOR CONTROLS

AMETEK NCC Dust Collector Controls offer
sequential control of solenoid valves for pulse
or shaker-damper cleaning of dust collectors.
They are also used for display lighting, intermittent valve or sequential control.

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

(SEQUENTIAL TIMERS)

Common Applications:

4-2

DUST COLLECTOR CONTROLS

Intermittent Use Collectors
Model T2101
FEATURES

SPECIFICATIONS

● Simple 4 wire installation
● Replaces electromechanical timers
● Completely solid state timing and

TIMING
Delay Time: 120 sec. ±10% fixed
Shake Time: Adjustable from 1.8 to 180 sec.
Repeatability: ±3% over temperature and voltage range
INPUT
Operating Voltage: 105 to 135 VAC
Power Consumption: 5.5 W plus shaker contactor coil power
Frequency: 50/60 Hz
OUTPUT
Type: Solid state switch, 1 A continuous at 1.5 V
below input voltage
TRANSIENT PROTECTION
Input: Transformer and large filter capacity
Output: Solid state switch rated for 10 A at 400V
protected by metal oxide varistor; 3 A fuse protects against external short circuit
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 70°C

switching logic

● High quality locking bushing

potentiometers for timing adjustment

● Very low power consumption
● Conformally coated for protection
●
●
●
●

against vibration, humidity, and contamination
LED function lights on PC board
Function indicating lights on T2101-020
Mounts in standard NEMA 4/JIC
enclosures
File #E65038

LOGIC FUNCTION DIAGRAM
Fan
Switch
Shaker
Load

New
cycle

On
Off
On
Off
2 minutes
fixed

1.8 sec.- 3 min
adjust

Operating Logic: The control is used on
intermittent type dust collectors to automatically activate the shaking mechanism 2
minutes after the fan motor is turned off.
Upon removing power from the fan, a 2
minute fixed delay is initiated. At the end
of the delay, the shaker output is activated
for an adjustable period of 1.8 seconds to
3 minutes. Resetting the control occurs by
turning the fan motor on again.
CAUTION: The control must be wired according to the schematic
provided.

ORDERING INFORMATION
DESCRIPTION

PART NUMBER

Control on Chassis

DNC-T2101-010

Control in Hinged NEMA 4 Box with Functional Lights

DNC-T2101-020

ACCESSORY
NEMA 4 Box
Pilot Lamp
On/Off Switch

DIMENSIONS

PART NUMBER

6” x 8” x 4”

BOX-A0606-CHNF

NEMA 4 Rated Red Light

ASL-00RED-NEMA 4

NEMA 4 Rated with Legend Plate

MSW-0DPST-011

AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a continuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

DUST COLLECTOR CONTROLS

Model DNC-2101-010

2.125 Max.
.625

.25

5.125
4.625
.25 DIA.
4 HOLES

.25

4-3

1.8 sec. 180

5.625
6.125

Shake Time
Adjust

1 2 3 4

3A

L1 L2
Metal Chassis
#6 screw typ.
(4250-1 10/92)

6.0
4.0

Model DNC-2101-020

4.875
1.0

6.75
7.5

Control Power On

.75

6.0

Load On

.312 DIA.
4 HOLES

L1

Fan
Start/Stop
Switch

Field Wiring Diagram

4

120
VAC

T2101

3
2
1

On

N.O.
Aux.
Shaker

L2

S Contactor
Coil

Off
Terminal
Block

L2

L1

Fan

F Contactor
Coil

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-4

DUST COLLECTOR CONTROLS

AC Input, Pulse Cleaning of
Bag House Dust Collectors

Models DNC-T2003 through DNC-T2032
FEATURES
● Digital Timing Circuitry: allows for sta●
●
●
●
●
●
●
●
●
●
●
●

ble timing from -40°C to 65°C temperature range
Pulse Time: line synchronized to eliminate 8 millisecond triac turn off variation
10 A-400/600V Output Triacs: for maximum protection against output shorts.
200 VA load rating
Conformally coated for protection
against vibration, humidity, and contamination
2 Modes of Operation: can be operated
Continuously or On Demand via external
pressure switch
Field Selectable: for numbers of outputs
required
LED Indicators: for compartment being
cleaned indication
Rugged Timing Adjustments: large stable potentiometers are used for ON and
OFF time adjustments
Metal Chassis Provided: for mounting
directly into NEMA 4 box
Timer Functionally Tested for 24
Hours: to eliminate field failures
Input Protection: 30 joule metal oxide
varistor
One Year Warranty: warranted to be free
from defects in materials or workmanship
for one year from date of manufacture
File #E65038

Operating Logic: The control can function
in 2 modes.
In Continuous Mode, the pressure switch
terminals are shorted. Upon application of
input voltage, the control activates output
#1 after the preset off time. It will continue
to activate outputs sequentially until input
voltage is removed.
In On Demand Mode, the pressure switch
terminals are connected to an isolated set
of contacts of a differential pressure switch.
The control will activate the outputs sequentially whenever the pressure switch contacts
are closed. When the pressure switch contacts open, the output sequencing stops.
Re-closing of the contacts will cause the
control to resume activating the outputs.

Program wire allows the user to select the
maximum number of outputs to be activated.
Note: Controls are shipped with jumper across pressure switch
terminals

SPECIFICATIONS
TIME DELAY
ON-Time: Adjustable from 50 to 500 ms
OFF-Time:
Range A: adjustable from 1.5 to 30 seconds
Range B: adjustable from 8.5 to 180 seconds
Note: Range S designates customer specified time range. Consult
factory for parameters

Repeatability: ±3% over temperature and voltage ranges
INPUT
Operating Voltage: 120 ±10%, 220 ±10% VAC
Frequency: 50/60 Hz
Power Consumption: 2 VA max.
OUTPUT
Type: Solid state switch (triac)
Switch Rating: 200 VA maximum per output
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Short Circuit Protection: 3 A fuse
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 70°C

Pressure
switch

TIMER #1

Alternate action
dual coil latching
relay. Contacts
shown with reset
coil energized last.

L1 L2 C 1 2 3 4 5 6 7 8 9 10
5

10

Input
voltage
120V

Last
Solenoid

1

N.O.

S

COM

N.C.

Pressure switch
N.O.

8

11

COM

N.C.

4

Set
coil

TIMER #2
Reset
coil

L1L2 C 1 2 3 4 5 6 7 8 9 10

13

9

12

14

Last
Solenoid
S
3867-1

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-5

DUST COLLECTOR CONTROLS
A

.25

C
OFF & ON Time
Adjustments

Pressure Switch InputFor on demand cleaning.
(Controls are shipped
with inputs shorted out)

OFF

.25 Dia. Hole
(4 Pl.)

Program WireDetermines number
of outputs to be
activated

ON

# 6 screw typ.

B

D

NOTE: Not all components
are shown. Component
locations can vary from
model to model.

.050 Aluminum
Chassis

3 AMP
(4250-2 10/92)

AC
Voltage
Input

.31

C

L1

1

2
Solenoid Valve

L2

.625
2.0 Max.

ORDERING INFORMATION
MAX.
NO. OF
OUTPUTS

DIMENSIONS
A

B

C

SIZE OF
NEMA 4 ENCLS.
REQUIRED

D

PROGRAMMABLE NO.
OF OUTPUTS

OFF TIME

PART NUMBER

DNC-T2003 THROUGH DNC-T2032 120 VAC INPUT VOLTAGE
3

6.75

4.875

6.25

4.25

8” x 6” x 3.5”

1-3

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2003-A10
DNC-T2003-B10

6

8.75

6.875

8.25

6.25

10” x 8” x 4”

2-6

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2006-A10
DNC-T2006-B10

10

8.75

6.875

8.25

6.25

10” x 8” x 4”

3-10

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2010-A10
DNC-T2010-B10

20

10.75

8.875

10.25

8.25

12” x 10” x 5”

11-20

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2020-A10
DNC-T2020-B10

32

12.75 10.875 12.25

10.25

14” x 12” x 6”

17-32

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2032-A10
DNC-T2032-B10

DNC-T2006 THROUGH DNC-T2032 220 VAC INPUT VOLTAGE
6

8.75

6.875

8.25

6.25

10” x 8” x 4”

2-6

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2006-A220
DNC-T2006-B220

10

8.75

6.875

8.25

6.25

10” x 8” x 4”

3-10

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2010-A220
DNC-T2010-B220

20

10.75

8.875

10.25

8.25

12” x 10” x 5”

11-20

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2020-A220
DNC-T2020-B220

32

12.75 10.875 12.25

10.25

14” x 12” x 6”

17-32

1.5 to 30 sec.
8.5 to 180 sec.

DNC-T2032-A220
DNC-T2032-B220

Note: Special time ranges are available with the following maximum to minimum time ratio restrictions: ON Time–10:1; OFF Time–20:1

ACCESSORY

DIMENSIONS

PART NUMBER

Enclosure for DNC-T2003

8” x 6” x 3.5”

BOX-A0806-CHNF

Enclosure for DNC-T2006

10” x 8” x 4”

BOX-A1008-CHNF

Enclosure for DNC-T2010

10” x 8” x 4”

BOX-A1008-CHNF

Enclosure for DNC-T2020

12” x 10” x 5”

BOX-A1210-CHNF

Enclosure for DNC-T2032

14” x 12” x 6”

BOX-A1412-CHNF

ACCESSORY
Pilot Lamp
On/Off Switch

DIMENSIONS
NEMA 4 Rated Red Light

PART NUMBER
ASL-00RED-NEMA-4

NEMA 4 Rated with Legend Plate

MSW-0DPST-001

Alternate Action Dual Coil Latch Relay

—

KDD-LATCH-120AC

Socket For Latch Relay

—

MSO-0D11P-012

AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a continuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-6

DUST COLLECTOR CONTROLS

DC Input, Pulse Cleaning of Bag House
Dust Collectors
Model DNC-T2010-ADC
FEATURES

SPECIFICATIONS

●
●
●
●
●
●
●

TIME SETTING RANGES
ON-Time: Adjustable from 20 to 200 ms
OFF-Time: Adjustable from 1.5 to 60 sec.
Repeatability: ±3% over temperature and voltage ranges
INPUT
Operating Voltage: 10.0 to 29.0 VDC (unfiltered
supply voltage must be full-wave rectified)
Power Consumption Voltage During Off Time:
1.5 W at 12 VDC, 4.2 W at 24 VDC
OUTPUT
Type: Solid state switch
Load Per Output: 3 A max. at 1.5 V less than
input voltage
PROTECTION
Transient Input Voltage: Metal oxide varistor
plus large filter capacity
Transient Output Voltage: Solid state switch
rated at 10 A to 60 V fly-back diode protected
Short Circuit Protection: 3 A fuse for circuit,
reverse polarity protected
ENVIRONMENTAL
Operating Temperature: -40°F to 150°F (-40°C
to 65°C)
Storage Temperature: -40°F to 185°F (-40°C to
85°C)

●
●
●
●

Field selectable from 2 to 10 outputs
Solid state timing and switching logic
300% overrated solid state switch
Pressure switch control option on board
12 to 24 VDC input voltage
Adjustable ON and OFF times
High quality locking bushing
potentiometers for timing adjustment
Very low power consumption
Conformally coated for protection
against vibration, humidity, and contamination
LEDs show compartment being cleaned
Metal chassis provided for mounting
directly into NEMA 4 enclosure

Operating Logic: The control can function
in 2 modes.
In Continuous Mode, the pressure switch
terminals are shorted. Upon application of
output voltage, the control activates output
#1 after the preset off time. It will continue
to activate outputs sequentially until input
voltage is removed.
In On Demand Mode, the pressure switch
terminals are connected to an isolated set
of contacts of a differential pressure switch.
The control will activate the outputs sequentially whenever the pressure switch contacts
are closed. When the pressure switch contacts open, the output sequencing stops.
Re-closing of the contacts will cause the
control to resume activating the outputs.
Program wire allows the user to select the
maximum number of outputs to be activated.
Note: Controls are shipped with jumper across pressure switch
terminals.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

DUST COLLECTOR CONTROLS

Pressure Switch InputFor on demand cleaning.
(Controls are shipped with
inputs shorted out)

NOTE: Not all components are shown.
.050 Aluminum
Chassis

8.75
8.25
OFF & ON Time
Adjustments

.25

OFF

4-7

.25 Dia. Hole
(4 Pl.)

ON

6.875
6.250

Program WireDetermines number
of outputs to be
activated

OUTPUTS (-)

+ - (+)

12-24VDC ONLY
.31

C

DC +
Voltage
Input

(4250-3 10/92)

#6 screw typ.
1

2

3

4

5

6

7

8

9 10

.625
2.0 Max.

Solenoid Valve

ORDERING INFORMATION
PROGRAMMABLE NO.
OF OUTPUTS

INPUT VOLTAGE

OFF TIME

PART NUMBER

2 to 10

12 to 24 VDC

1.5 to 60 sec.

DNC-T2010-ADC

ACCESSORY
NEMA 4 Box
NEMA 4 Box
ON/OFF Switch

DIMENSIONS

PART NUMBER

10” x 8” x 4”

BOX-A1008-CHNF

12” x 10” x 5”

BOX-A1210-CHNF

NEMA 4 Rated with Legend Plate

MSW-0DPST-011

AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a continuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-8

DUST COLLECTOR CONTROLS

Pulse Jet Dust Collector Control with Extended Cycle
DNC-T2110 Series
FEATURES
● Digital Timing Circuitry: allows for sta●
●
●
●
●
●
●
●
●
●
●
●

ble timing from -40°C to 65°C temperature range
Pulse Time: line synchronized to eliminate 8 millisecond triac turn off variation
10 A-400/600V Output Triacs: for maximum protection against output shorts;
200 VA load rating
Conformally coated for protection
against vibration, humidity, and contamination
2 Modes of Operation: can be operated
Continuously or On Demand via external
pressure switch
Extended cycle capability for added
pulses after pressure switch opens
Field Selectable: for numbers of outputs
required
LED Indicators: for compartment being
cleaned indication
Rugged Timing Adjustments: large stable potentiometers are used for ON and
OFF time adjustments
Metal Chassis Provided: for mounting
directly into NEMA 4 box
Timer Functionally Tested: to eliminate
field failures
Input Protection: 30 joule metal oxide
varistor
One Year Warranty: warranted to be free
from defects in materials or workmanship
for one year from date of manufacture

Operating Logic: The DNC-T2110-A10/
B10 are ten output sequencer, cycle timers with adjustable ON-TIME, OFF-TIME
and DELAY times. When voltage is applied
to L1 and L2 and the pressure switch is
closed, the OFF-TIME is started, At the
end of the preset OFF-TIME the control
will cycle through the outputs until the
pressure switch opens. The ENABLE/
DISABLE switch on the control can enable
the OFF-DELAY. When the pressure switch
opens and the OFF-DELAY is enabled, then
the OFF-DELAY time is started and the
OFF-TIME, ON-TIME cycles will continue
until the end of the OFF DELAY time. If the
OFF-DELAY times out during the ON-TIME,
the control will allow the ON-TIME to time
out. Upon closing of the pressure switch
the control will commence the OFF-TIME,
ON-TIME sequence on the next output and
the OFF-DELAY time will reset. If the pressure switch is closed during the OFF-DELAY
time, the control will reset the OFF-DELAY.
The ENABLE/DISABLE switch on the control can disable the OFF-DELAY. When the
OFF-DELAY is disabled and the pressure
switch opens, during the ON-TIME, the
control will allow the ON-TIME to time out.
Upon closing of the pressure switch the
control will commence the OFF-TIME, ONTIME sequence on the next output.

LOGIC FUNCTION DIAGRAM
INPUT
VOLTAGE

OFF DELAY

PRESSURE
SWITCH

ON
OFF
ENABLED
DISABLED
CLOSED
OPEN
OFF DELAY

OUTPUTS

OUTPUT 1

OUTPUT 2

OUTPUT 8

PULSE
OFF
ON TIME

ON
OFF
ON
OFF
ON
OFF

OFF
TIME

ON TIME

OFF
TIME

ON TIME

OFF
TIME

ON TIME

ON TIME

OFF
TIME

OFF TIME

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

DUST COLLECTOR CONTROLS

4-9

8.750
.250

8.250
PRESSURE SWITCH
(SUPPLIED BY CUST.)

75

100

PROGRAM WIRE

550

3

125

2

PRESSURE
SWITCH

ENABLE

2

850

3

5
6
4
8
7
ATTACH TO LAST
OUTPUT USED

9 10

250

1
.5

8.5 sec. 180
OFF TIME

700

400
4

150

.250 DIA
(4 HOLES)

sec.

5

100

sec. 1000
DISABLE

OFF DELAY

6.250

ON TIME

POWER

ON

OUTPUTS
(200 VA/OUTPUT MAX)

LINE
L1 L2

SOL.
COM

1

2

3

4

5

6

7

8

9

10

3 AMP
Do not use Slow Blow
or larger size. Failure
to comply will void Line voltage must be
the Warranty
105 to 135 volts.In
grounded system
s
connect neutral of
line to L2.

National Controls
Corporation

PROGRAM CONTROL
Line Voltage:105to135 VAC,50-60H
z

.312

TIME DELAY
OFF-Delay Time: Adjustable from 100 sec. +0%,
-50% to 1000 sec. +10%, -0%. OFF Delay Time
can be disabled
ON-Time: Adjustable from 50 to 500 ms
OFF-Time:
Range A: adjustable from 1.5 to 30 seconds
Range B: adjustable from 8.5 to 180 seconds
Repeatability: ±3% over temperature and voltage ranges
INPUT
Operating Voltage: 105 to 135 VAC
Frequency: 50/60 Hz
Power Consumption: 5 VA max.
OUTPUT
Type: Solid state switch (triac)
Switch Rating: 200 VA max. per output, 1.8 VAC
RMS max.; ON state voltage drop 4 mA max.;
OFF state leakage current at 120 VAC
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Short Circuit Protection: 3 A fuse
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 85°C

6.875

SPECIFICATIONS

L1
L2

2.0 MAX

.625
MAX

ORDERING INFORMATION
PROGRAMMABLE NO.
OF OUTPUTS
1 to 3

ACCESSORY
NEMA 4 Box
Pilot Lamp
On/Off Switch

OFF TIME

PART NUMBER

1.5 to 30 sec.

DNC-T2003-A10

8.5 to 180 sec.

DNC-T2003-B10

DIMENSIONS

PART NUMBER

10” x 8” x 4”

BOX-A1008-CHNF

NEMA 4 Rated Red Light

ASL-00RED-NEMA 4

NEMA 4 Rated with Legend Plate

MSW-0DPST-011

AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a continuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-10

DUST COLLECTOR CONTROLS

DUSTRONIX™ Core-10/Expander-10
Dust Collector Controls
Models DNC-T2610-010/020
FEATURES
● Communicates via 2 wire CANbus network

● Universal input voltage 100-240 VAC,
50/60 Hz

● 10 outputs on-board, expands to 990
outputs (with expansion boards)

● Solenoid current sense:

– allows automatic system setup
– senses 3 solenoids per output
– monitor up to 2970 solenoids
● Diagnostic/program LEDs for “at-aglance” system status indication
● Settable to read 0-10, 0-15, and 0-25
inches of differential pressure
● Finger-safe terminations

CORE-10 UNIQUE FEATURES
● Simple one knob programming
● Non-volatile memory for program and
status storage
● On-Demand operation:
– with external pressure switch (not
included)
– with external pressure sensor (not
included)
– source/sink 4 to 20 mA sensor input
● 3-digit, 7-segment alpha-numeric
display
● Settable alarm output relay normally
open or normally closed

The Core-10 is the main control module in the
DUSTRONIX line. The Core-10 is capable of
operating as a standalone module controlling
1 to 10 solenoids, or in combination with the
Expander-10 for up to 98 expansion modules for
a total of 990 outputs. The Expander-10 is the
expansion output board in the DUSTRONIX family. The Expander-10 operates in combination with
the Core-10 Control Module.

The Expander-10 communicates with the Core10 on a twisted pair of wires using CANbus architecture which provides robust noise immunity.
Two rotary switches on the Expander-10 are used
to set and provide visual indication of the address
assigned.
The Core-10 can operate in On-Demand mode
with input from an external pressure sensor (4 to
20 mA) or a pressure switch (not included), or it
can operate in the Continuous mode by use of a
jumper across the pressure switch input. A switch
can also be connected to the pressure switch
input to act as a bypass switch. Input for a cycle
down switch is also provided to allow for end-ofoperation cleaning.
A unique feature of the Core-10 is its simple
one-button programming. This single push-button/encoder is used to select operating parameters. LEDs indicate program function. The
push-button is also used to view alarm conditions
and cancel the alarm output. Operating and programming information is displayed on a 3-digit
7-segment display. The compact size of the
Core-10 and the Expander-10 allows mounting in
enclosures as small as 8” x 6”.

Programmable Parameters:
● Solenoid ON-Time/OFF-Time
● Number of cycle down cycles
● Cycle down time delay
● Run/Standby: enable/disable outputs
● Differential pressure high setpoint/low
setpoint
● Differential pressure high alarm setpoint/
low alarm setpoint
● Alarm contact (normally open or normally
closed)
● Differential Pressure Sensor Select:
10, 15, 25 in. w.c.
● Output: 1 to 990 manual or auto-configured
Status LEDs: when illuminated

● Differential Pressure: Display indicates
P

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

100 to 240 VAC

DNC-T2610-010

100 to 240 VAC

DNC-T2610-020

ACCESSORY
Enclosure for DNC-T2610-010

DIMENSIONS
10” x 8” x 6”

● Output: Display indicates current output

● Alarm (System Status):  P or
Solenoid Fault

● Output Pulsing: Display indicates output being pulsed

● Cycle Down: Unit in cycle down
mode

● Output Status: Unit pulsing
solenoids

● CANbus Status: CANbus transmission activity

DUSTRONIX “Kit” Configurations
1. DNC-T2610-N4A: Includes
Core-10, PS700, 3-position
switch, NEMA 4 10”x8”x6” metal
enclosure with cutouts, bulkhead fittings, mounting chassis,
mounting
2. DNC-T2610-N4XA: Same as
above but mounted in fiberglass
enclosure
3. DNC-T2610-N4B: Same as Kit
1 but also includes Expander-10
module
4. DNC-T2610-N4XB: Same as
Kit 3 but mounted in fiberglass
enclosure

PART NUMBER
BOX-A1008-CHSC
BOX-A1008-CHNF

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

DUST COLLECTOR CONTROLS

4-11

–
+

SHOWS "SINK"
SHOWS "SOURCE"
ALARM
POWER

P
SENSOR

P
SENSOR

ALARM

N.O. N.C.

TWISTED PAIR COMMUNICATIONS CABLE
TO EXPANSION UNITS (IF USED)
2

Alarm

Alarm

Pressure

Output Pulsing

4.25 (107.95)

Cycle Down
Run

Solenoid Output
Solenoid On Time

Standby
Pressure High Set Point

Solenoid Off Time

Pressure Low Set Point
Pressure High Alarm Point

Cycle Down Delay Time

Pressure Low Alarm Point

.25 (6.35)

Cycle Down Cycles

N a t i o n a l C o n t r o l s C o r p..

.25 DIA. HOLE (4 PL.)
(6.35)

E65038

3.15A

GND
L1
L2

.50
(12.7)

100-240 VAC

1.50
(38.1)

.313 (7.95)

6.25 (158.75)
6.875 (174.63)

OUTPUTS TO 120 OR 240V AC AIR SOLENOIDS
L2 TERMINALS ARE INTERNALLY CONNECTED TO L2 SUPPLY

CORE-10

.25 DIA. HOLE (4 PL.)
(6.35)
2

1

TWISTED PAIR COMMUNICATIONS CABLE
TO MAIN CONTROLLER AND OTHER
EXPANSION UNITS (IF USED)

.25 (6.3)

3.225 (82.0)

INPUTS
Supply: 100-240 VAC, 50/60Hz, 4 VA max. at
240VAC without loads
Fuse: 3A fast, 5x20 mm
 Pressure Sensor Input: 4 to 20 mA, sink/
source, programmable 10.0”, 15.0”, 25.0” w.c.
 Pressure Switch Input: Dry contact, 4 mA at
13 VDC max.
Cycle Down Switch Input: Dry contact, 4 mA at
13 VDC max.
OUTPUTS
Solenoid Outputs: 10
Output Type: Triac
Output Rating: 150 VA (at max. ON, min. OFF, 1
output selected)
Timing Accuracy: -2mS, +10 mS or +1% (whichever is greater), ON-time synchronized to AC line
Alarm Relay: Form-A contact, 3A at 250
VAC/30 VDC, programmable normally open or
normally closed
DISPLAY INDICATORS
3-digit 7-segment LED display, 0.56 in. red
Program Parameters/Display Status/CANbus
Status: 17 green LEDs
Alarm: 1 red/yellow LED
Output Status: 1 red/green LED
PARAMETER RANGES
ON-Time: 0.050-600 sec.
OFF-Time: 1-999 sec.
Timing Accuracy: -2 ms, +10 ms or +1% (whichever is greater), ON-time synchronized to AC line
Cycle Down Cycles: 1-20, none
Cycle Down Delay: 60-600 sec.
 P High Setpoint: 0-10/15/25” w.c., none
 P Low Setpoint: 0-10/15/25” w.c., none
 P High Alarm: 0-10/15/25” w.c., none
 P Low Alarm: 0-10/15/25” w.c., none
COMMUNICATIONS
Type: CANbus architecture
Terminations: Screw terminals, #12 to #28 AWG,
finger safe
ENVIRONMENTAL
Operating Temperature: -40°F to +150°F (-40°C
to +65°C)
Environmental Protection: Conformal coating
for humidity and vibration

3.725 (94.6)

CORE-10

4.75 (120.65)

Output

SPECIFICATIONS

1

GND
L1
L2

OUTPUTS TO 120 OR 240V AC AIR SOLENOIDS
L2 TERMINALS ARE INTERNALLY CONNECTED TO L2 SUPPLY
100-240 VAC

6.250 (158.75)

.313 (7.95)

6.875 (174.63)

EXPANDER-10

EXPANDER-10 SPECIFICATIONS

INDICATORS
Solenoid Pulse Indication: 10 green LEDs
CANbus Status: 1 green LED
Output Status1: 1 red/green LED
OUTPUTS
Solenoids: 10 per Expansion Module
Output Type: Triac
Output Rating: 150 VA (at max. ON, min. OFF, 1
output selected)
Timing Accuracy: -2 ms, +10 ms or +1% (whichever is greater), ON-time synchronized to AC line

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-12

DUST COLLECTOR CONTROLS

DUSTRONIX™ Pressure Differential Meter
Model DNC-PS700-A10
FEATURES
● 51 element tri-color LED meter movement

●  P control relay output: programmable,
normally open or normally closed

●  P alarm relay output: programmable,
●
●
●
●
●
●
●
●
●
●
●
●

normally open or normally closed
Cleaning status LED
Alarm status LED
0-10” w.c.  P range
Source or sink 4 to 20 mA  P output
1/4 DIN panel mountable
NEMA 4 compatible
3-digit, 7-segment alpha-numeric
display
Removable finger-safe terminations
Replaces most popular  P switches/
gauges
Non-volatile memory
User selectable program access code
Universal input voltage

Programmable Parameters:
● Alarm Low/High setpoints
● Cleaning Low/High setpoints
● Alarm relay (normally open or normally
closed)
● Cleaning relay (normally open or normally closed)
● Units of measure (inches, w.c. or kPa)
● Security code (user settable)
●  P offset compensation capability
The DUSTRONIX Pressure Differential Meter is
designed to interface with NCC dust collector
controls as well as other controllers. This meter
is capable of measuring differential pressure and
displaying that value in both analog bargraph
and digital displays. Both Low/High Cleaning and
Low/High Alarm setpoints can be programmed
with relay outputs. The Cleaning relay will energize when the measured pressure exceeds the
High Cleaning Setpoint, and will de-energize
when the pressure goes below the Low Cleaning
Setpoint. The Alarm relay will energize whenever
the measured pressure exceeds the High or Low
Alarm Setpoint.
The DUSTRONIX Pressure Differential Meter
will accept either a 0 to 10” w.c. pressure input
or a 4 to 20 mA input. A 4 to 20 mA output loop
is provided when the internal pressure sensor
is used. A 3-digit security code is also provided
to prevent unauthorized changes. The meter is
equipped with non-volatile memory which will
store all operating parameters when power is
removed.

Operating Logic: The DUSTRONIX Pressure
Differential Meter is shipped with factory
default settings (see details below). A pressure or 4 to 20 mA input needs to be connected, outputs wired as required, and
power applied to have a functioning system.
Program parameters can now be set for the
specific application.

SPECIFICATIONS
FACTORY DEFAULT SETTINGS
Low Alarm Setpoint = 1.0
High Alarm Setpoint = 8.0
Low Cleaning Setpoint = 2.0
High Cleaning Setpoint = 4.0
Alarm Relay = Ano
Cleaning Relay = Cno
Units = IN
Security Code = 0.0.0.
INPUTS
Voltage: 100-240 VAC, 50/60 Hz
Power Consumption: 5 VA max. at 240 VAC
OUTPUTS
Alarm Output Type: Form A relay contact, programmable normally open or normally closed
Alarm Output Rating: 5 A at 240 VAC/30 VDC
Control Output Type: Form-A relay contact, programmable normally open or normally closed
Control Output Rating: 5 A at 240 VAC/30 VDC
CURRENT LOOP
Type: 4 to 20 mA current loop, switch selectable
sink/source, represents 0 to 10” w.c.  pressure
Accuracy: ±0.3 mA of displayed pressure
Measurement: Current of 4 to 20 mA or pressure
of 0 to 10 in. water
MECHANICAL
Enclosure: 1/4 DIN meter face
Material: 304 stainless steel
Electrical Terminations: Removable screw terminals, 14-22 AWG
Pressure Terminations: Removable 0.125” hosebarb type fittings
PRESSURE SENSOR
Type: Silicon piezoresistive transducer
Measurement Range: 0.0 to 10.0 in. water
(0-2.5 KPa)

The PS700
may be purchased
separately as an accessory
to NCC Dust Collector
Controls, as well as other
controllers

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

100 to 240 VAC

DNC-PS700-010

ACCESSORY
NEMA 4 enclosure for DNC-PS700-010

DIMENSIONS
8” x 6” x 3.5”

PART NUMBER
BOX-A0806-CHNF

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-13

DUST COLLECTOR CONTROLS

E165149
US
R

1.6

BLACK INK
SCREENING
6
7

3
S/N:

9
2.2

.2

2.4

2

1.0

10

1.2

1.4

.8

MODEL NO. DNC-PS700-A10
DIFFERENTIAL PRESSURE METER

.4

8

1.6
1.8

.6

1

MANUFACTURED BY
NATIONAL CONTROLS CORPORATION
1725 WESTERN DR. WEST CHICAGO, IL. 60185
FOR SERVICE CALL
(800)323-2593

2.0

2.0

9

.4

2.2
.2

2.4

0

10

Digital Meter

N a t i o n a l C o n t r o l s C o r p..

N a t i o n a l C o n t r o l s C o r p..

CLEANING RELAY
OUTPUT CONTACTS
85 - 240 VAC
50/60 Hz

FRONT VIEW
REMOVABLE
MOUNTING BRACKET
(2 PLACES)
SHOWN FOR REFERENCE

4 - 20 mA
OUTPUT

L2
L1

ELECTRICAL CONNECTIONS

3.298
3.111

8 POS. CONNECTOR
PHOENIX #17-57-30-7
OR EQUIVALENT

ALARM RELAY
OUTPUT CONTACTS

}

TOP VIEW

+

Digital Meter

-

0

5

4

1.8

.6

}

.8

8

}

1.4

}

1.2

4.000

7
1.0

1

RANGE: 0-10 INCHES OF WATER
INPUT VOLTAGE: 90-265 VAC 50/60 Hz 5VA MAX.
INPUT PRESSURE: 0-10 INCHES OPERATING PRESSURE
OUTPUT RATINGS:
CONTROL/ALARM OUTPUT: 5 AMPS 120/240VAC/30VDC
4-20 MA OUTPUT: 0-10 INCHES OF WATER
CURRENT SOURCE OUTPUT
450 OHMS MAX LOOP RESISTANCE

6

3
2

C

5

4

POLYESTER
OVERLAY

4.000

FOR REMOVEABLE 8 POSITION CONNECTOR

- +

Accuracy: ±2% of full scale at 77°F (25°C); ±5%
of full scale over temperature and voltage range
Maximum Continuous Pressure: 10 psi
DISPLAYS
Units: Programmable for in. water or kPa
Bargraph Display: 51 element tri-color LED analog differential pressure bargraph
Green = Differential pressure
Yellow = Cleaning setpoints
Red = Alarm setpoints
Digital Display: 3-digit, 7-segment differential
pressure display, 0.3 in. tall

RIGHT SIDE VIEW

.750
MAX.

L2

L1

(-)
4-20mA
(+)

CLEAN

MOUNTING BRACKET
ASSEMBLY
ALARM

CLEAN AIR
PLENUM

4-20mA

BOTTOM VIEW

SHOWN WITH ELECTRICAL
CONNECTOR REMOVED

+0.000
3.625-0.025

3.500

CLEAN 90-265
VAC
RELAY
INPUT
OUTPUT

DIRTY AIR
PLENUM

ALARM
RELAY
OUTPUT

3.500

8 POS.
REMOVEABLE
CONNECTOR
MOLEX #398600308
OR EQUIVALENT

+0.000
3.625-0.025

RECOMMENDED PANEL CUT-OUT

Range: 00.0 to 10.0 in. (00.0 to 02.5 KPa), shows
“OPn” with no sensor connected or with vacuum
applied
Discrete LED Indicators:
Cleaning = Green
Alarm = Red / Yellow
ENVIRONMENTAL
Operating Temperature Range: 32° to 150°F (0°
to 65°C)
Protection: Conformal coating on PCB for
humidity and vibration

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-14

DUST COLLECTOR CONTROLS

Intelligent, AC-Input, Pulse Cleaning
of Bag House Dust Collectors
Models DNC-T2310 and DNC-T2320
FEATURES
●
●
●
●
●

●
●
●
●
●
●
●
●
●
●
●
●
●
●

●

On-board differential pressure sensor
4 - 20 mA output for DP
8 character alpha-numeric display
Microprocessor based control for stable
timing from -40°C to 65°C
Enhanced timer option: monitor additional devices; record dust collector
data; network timers together remote
network monitor; remote network control
RS232 port for remote monitor and control
Automatic output setup capability
Expanded cycle mode allows additional
dust collector controllers to expand output capabilities
High pressure alarm indication
Output fault detection
Alarm output contacts
Alarm input sensors
Pulse time: line synchronized to eliminate 8 ms triac turn off variation per
output
10 A 400 V output triacs for maximum
protection against output shorts; 200 VA
load rating
Conformally coated for protection
against vibration, humidity, and contamination
Metal chassis provided: for mounting
directly into nema 4 box
Timer functionally tested to eliminate
field failures
Input protection: 30 joule metal oxide
varistor
One year warranty: warranted to be
free from defects in materials or workmanship for one year from date of manufacture
File #E65038

Models T2310 and T2320 are microprocessor-based bag house filter controllers
which combine a ten or twenty output
sequencer with a solid state differential
pressure sensor. This offers a small, lowcost replacement to the separate solid state
sequencer and pressure gauge combination
most often used in on-demand pulse jet
cleaning systems. These controllers will
sense the pressure difference across the
filters of a bag house and initiate a cleaning

cycle when the filters start to impede the air
flow. When the pressure drops to normal the
controller will stop cycling.
Standard Operating Logic: The timers can
operate in the following modes:
● Auto output: only configured outputs will
be pulsed. Output faults will be detected
and indicated.
● Manual output: outputs will recycle after
last output used.
● Output step: a single cleaning pulse can
be initiated by pressing the output step
key regardless of pressure input.
● Continuous cycle: controller will cycle
indefinitely when the bypass/cycle down
input is shorted.
● Cycle down: the outputs will be pulsed
through a user seleced number of complete cycles when the bypass/cycle down
input is shorted. This cycle will occur
regardless of pressure input.
● Expanded output mode: controller will
cycle to output #10 or #20, then will initiate an extended output mode via the
alarm input and output terminals to
NCC’s DNC-T2000 series dust collector controllers. This will facilitate systems which require greater than 10 or 20
outputs.
Standard Timer Operation Status
Indication: The Timer can show the following information on its 8-character alphanumeric display during normal operation:
● DP from 0” to 15” water column
● High or Low DP Alarms
● Solenoid Fault Conditions
● Current Output being Pulsed
● Auxiliary Alarm Input Closures
Upon occurance of any alarm event, the
alarm status is reported on the display
along with the output number that was
pulsed during the time of the event.
● Alarm Outputs: The isolated Alarm
Output contacts will close for alarm
conditions such as output faults,
high pressure alarm, warm-up failure,
etc. During an alarm condition, a
corresponding message is displayed.
● Alarm Input: A closure across the Alarm
Input terminals will be indicated on
the display as well as initiate the Alarm
Output.

In addition to the standard operation of the T2310 and T2320,
an enhanced operation option
is available with the use of the
DNC-T2300-I/O Remote Input/
Output module in conjunction
with the DNC-T2300-DSP Remote
Annunciator Panel. The T2310
and T2320 Timers along with the
DNC-T2300-I/O constitutes the
Enhanced Timer system which
allows the user to monitor and
record the data parameters associated with a dust collector system.
This system can range in size from
1 to 255 dust collectors, all reporting to a central location, the DNCT2300-DSP.
Enhanced Timer Operation
Status Indication: The Timer can
show the following information on
its 8 character alpha-numeric display during normal operation:
● DP from 0” to 15” water column
● High or Low DP Alarms
● Solenoid Fault Conditions
● Current Output being Pulsed
● Auxiliary Alarm Input Closures
● DNC-T2300-I/O Analog Input
Status
● DNC-T2300-I/O Alarm Input
Closures
Upon occurance of any alarm
event, the alarm status is reported
on the display along with the output number that was pulsed during
the time of the event.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

DUST COLLECTOR CONTROLS

4-15

OUTPUT
STEP

ITEM

VALUE
ALAR M

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

S/N:

PRESSURE SWITCH INPUT

BYPASS
INPUT

PRESSURE
CONNECTIONS:
HI SIDE

Date Code:

LOW SIDE

ALARM
OUTPUT
ALARM
INPUT

N.O.

3AMP

Programming Logic: The controller as supplied from the factory will require user configuration. Upon application of power the
display will indicate SETUP. The operator
must then configure the various operating
parameters using the six key keyboard of
the controller before normal cleaning operation can begin. The programmable parameters for Standard Operation as displayed
are:
● OUTPUT
Auto Configuration: will automatically
sense the solenoids connected to the
outputs and will only pulse those outputs
during cleaning cycles.
Manual Configuration: the controller will
pulse each output until the last output
programmed and then recycle to output
#1.
● LAST: the number of the last output
used.
● LO DP: Low Pressure Setpoint, the pressure at which the controller will stop its
cleaning cycle.
● HI DP: High Pressure Setpoint, the pressure at which the controller will start its
cleaning cycle.
● ON: Output Solenoid On Time.
● OFF: Off Delay Time Between Output
Solenoid Activation.
● ALARM: High Differential Pressure Alarm
Set-point, the pressure at which the controller will close its alarm contacts.

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr
.
West Chicago, IL. 6018
5

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA

DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID ANY
WARRANT Y

RS232 Port:
● Remote Terminal: An ANSI type terminal is required for remote monitoring and programming of the controller.
Connection to the controller is made via
the RS232 port (9 pin D-Sub connector). All the functions and display status
accessible from the controller are available through the ANSI terminal.
● Remote I/O Interface: The 2310/2320
controllers are capable of communication
with the DNC-T2300-I/O board via the
RS232 port. This allows the user to monitor up to three 4-20 mA analog inputs,
three contact closure type inputs, and
one Type J thermocouple. The I/O module is programmed via the 2310/2320
keypad and can be user defined to set
alarm points from remote sensors of
parameters such as emission, air flow,
pressure, broken bags, fan motor current,
etc. Refer to the data sheet for the DNCT2300-I/O for additional information.

CANCEL

COI L

L1

L2

SOL
COM

National Controls
Corporation

1

2

3

4

5
6
OUTPUTS

7

8

9

10

Model DNC-T2310-010

120 VAC Coil
SPST-NO
Relay

DNC-T2003 Through
DNC-T2032 Series
Dust Collector Controller
(DNC-T2010 model shown)
L1 L2 C 1 2 3 4 5 6 7 8 9 10

S

Last solenoid

INPUT VOLTAGE 120 VAC
EXPANDED MODE WIRING DIAGRAM FOR DNC-T2310-*10

AUX OUTPUT
#4

AUX INPUT
#4

-T2320-

PRESSURE SWITCH

DNC SERIES DUST
COLLECTOR CONTROLLER
(EXCEPT T2310)
DNC-T2010 MODEL SHOWN
L1L2 C 1 2 3 4 5 6 7 8 9 10

S

INPUT VOLTAGE 120 VAC
L1

L2

LAST SOLENOID

EXPANDED MODE WIRING DIAGRAM FOR DNC-T2320-*10

For enhanced timer programming information, see IDC Programming Tree on page
4-6.
Additional Features: The 2310/2320 controllers also provide:
● 4 - 20 mA Output Loop: This output will
provide a continuous reading from 4 -20
mA corresponding to the sensed differential pressure range of 0” to 15” water column. This is a standard feature.
● 24 Hour Time/Day/Month Clock: The
clock feature will allow a daily automatic turn on and turn off command to be
implemented by the controller. It can be
programmed to start and stop the cleaning cycles for up to seven events per
week. This is an optional feature found on
the B-series models.

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-16

DUST COLLECTOR CONTROLS

SPECIFICATIONS
FACTORY DEFAULT SETTINGS
Lo Pressure = 2” water column
HI Pressure = 4” water column
Alarm Pressure = 14” water column
Output Quantity = 10
Off Time = 15 seconds
On Time = 0.10 seconds
Output Configuration = Manual
I/O Expansion = No
INPUTS
Voltage: 105 -135 VAC, 50/60 Hz.
Maximum Ratings at 135 VAC Input Voltage:
Power Consumption: 10 VA, without loads
DNC-T2310:
Bypass Switch Open Circuit Voltage: 24 VDC
Bypass Switch Short Circuit Current: 4.3 mA
Alarm Inputs 1-3:
Open Circuit Voltage: 24 VDC
Short Circuit Current: 4.3 mA
DNC-T2320:
Bypass Switch Open Circuit Voltage: 24 VDC
Bypass Switch Short Circuit Current: 4.3 mA
Alarm Inputs 1-3:
Open Circuit Voltage: 24VDC.
Short Circuit Current: 4.3 mA
Auxiliary Input #4: 90-135 VAC, 50/60 Hz;
6.6 mA at 135 VAC

AIR PRESSURE MEASUREMENT
Sensor Type: Silicon piezoresistive transducer
with dual inlets
Measurement Range: 0.0 to 15.0” of water
Accuracy: ±2% of full scale at 25°C ±6% of full
scale over temperature and voltage range
Maximum Continuous Pressure: 10 psi
DISPLAY
Type: 8-character, 16-segment vacuum fluorescent display; characters .2” high, alpha-numeric
TIMING:
Solenoid ON Time Range: .01-.50 sec.
Solenoid OFF Time Range: 7 -999 sec.
Timing Accuracy: -2 ms, +10 ms or ±1%, whichever is greater; Solenoid ON Time is synchronized
to the AC line
OUTPUTS
Maximum Solenoid Output: 200 VA or W at
max. duty cycle
Solenoid Output Voltage: Input voltage 2.5 VAC
at 200 VA load
Solenoid Output Type: Solid state triac
Solenoid Output Short Circuit Protection:
3 AG fast acting
120 V units: 3 A/250 VAC fuse
240 V units: 1.5 A/250 VAC fuse
DNC-T2310:
Alarm Output Type: 1-FORM A relay contact
Alarm Output Rating: 3 A at 120/240 VAC

DNC-T2320:
Alarm Output Type: 1-FORM A relay
contact
Alarm Output Rating: 3 A at 120/240
VAC
Aux. Output #4 Type: 1-FORM A relay
contact
Aux. Output #4 Rating: 3 A at 120/240
VAC
Current Loop:
Type: 4 - 20 mA current loop, current
is sourced by the controller. Signal
represents 0 to 15 inches of differential
pressure (DP)
Accuracy: ±.3 mA of displayed pressure
SERIAL COMMUNICATIONS
Type: RS232
Terminal Emulation: ANSI VT100
Mode: 9600 Baud, 8-Data Bits 1-Start
Bit 1-Stop Bit, X ON - X OFF, No Parity
Connector: 9-Pin male IBM compatible
D-SUB connector
ENVIRONMENTAL
Operating Temperature Range: -40°
to 65°C
Environmental Protection: Conformal
coating for humidity and vibration
Contact factory for additional information

ORDERING INFORMATION
OUTPUTS

AUX. INPUTS

INPUT VOLTAGE

OFF TIME

PART NUMBER

10

4-20 mA Loop

DESCRIPTION

3

105 to 135 VAC

7 to 999 sec.

DNC-T2310-A10

10

4-20 mA Loop and 24 hr. clock

1

105 to 135 VAC

7 to 999 sec.

DNC-T2310-B10

10

4-20 mA Loop

3

210 to 270 VAC

7 to 999 sec.

DNC-T2310-A220

10

4-20 mA Loop and 24 hr. clock

1

210 to 270 VAC

7 to 999 sec.

DNC-T2310-B220

20

4-20 mA Loop

4*

105 to 135 VAC

7 to 999 sec.

DNC-T2320-A10

20

4-20 mA Loop and 24 hr. clock

2*

105 to 135 VAC

7 to 999 sec.

DNC-T2320-B10

20

4-20 mA Loop

4*

210 to 270 VAC

7 to 999 sec.

DNC-T2320-A220

20

4-20 mA Loop and 24 hr. clock

2*

210 to 270 VAC

7 to 999 sec.

DNC-T2320-B220

10

4-20 mA Loop in NEMA 4X box

3

105 to 135 VAC

7 to 999 sec.

DNC-T2310-KIT

20

4-20 mA Loop in NEMA 4X box

4*

105 to 135 VAC

7 to 999 sec.

DNC-T2320-KIT

ACCESSORY

DIMENSIONS

PART NUMBER

NEMA 4 Enclosure - Steel

10” x 8” x 4”

BOX-A1008-CHNF

NEMA 4 Enclosure - Steel

12” x 10” x 5”

BOX-A1210-CHNF

NEMA 4 Window Enclosure - Fiberglass
Pilot Lamp
ON/OFF Switch

12” x 10” x 6”

BOX-A1210-CHSC

NEMA 4 Rated Red Light

ASL-00RED-NEMA-4

NEMA 4 Rated w Legend Plate

MSW-0DPST-001

* When unit is configured for expanded mode operation, input #4 is not available

AMETEK NCC offers NEMA 4 type enclosures for
mounting our controls. These enclosures are made of
heavy gauge steel or fiberglass and have a continuous hinge cover. All seams are continuously welded.
The finish is gray hammer-tone enamel inside and
out, over phosphatized surfaces for steel units,
smooth gray finish for fiberglass units.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-17

DUST COLLECTOR CONTROLS

Model
DNC-T2310-A10

VACUUM FLUORESCENT
DISPLAY (8 CHAR.)
(16 SEGMENT)
6.875

POLYESTER OVERLAY
.25 DIA MOUNTING HOLE

KEYPAD

(4 PL.)

6.250

.312

RS-232 9 CIRCUIT
MALE CONNECTOR

2.275

2.5 MAX.

2 POS. SCREW TERMINAL
(3 PL.)

OUTPUT
STEP

.25

ITEM

VALUE

DIFFERENTIAL PRESSURE
CYCLE BYPASS INPUT

ALARM

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

.65

CANCEL

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr.
West Chicago, IL. 60185

S/N:

BYPASS
INPUT

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA

REMOTE ALARM
CONDITION OUTPUT

PRESSURE
CONNECTIONS:
HI SIDE

Date Code:

AUX ALARM
INPUTS

ALARM

ALARM

OUTPUT

ALARM VOLTAGE SOURCE

ALARM

LOW SIDE

8.75

INPUT

8.25

REMOTE ALARM
CONDITION INPUT

DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID ANY
WARRANTY

L1

L2

2

1

SOL
COM

3

5
6
OUTPUTS

4

7

8

9

USER HOOKUP
'HI' SIDE (DIRTY AIR PLENUM) AND
'LOW' SIDE (CLEAN AIR PLENUM )
PRESSURE CONNECTIONS
1/8-27" NPT FEMALE
FITTING CONNECTION
(2 PL.)

10

Model DNC-T2310-010

National Controls
Corporation

FUSE

L1

.06 THICK
ALUMINUM MOUNTING
PLATE

10 -OUTPUTS TO 120 VAC SOLENOID
AIR VALVES. SOL. COM. TERMINAL IS
INTERNALLY CONNECTED TO L2 TERMINAL.

L2

#6 SCREW TERM.
(13 PL.)

POLYESTER OVERLAY

Model
DNC-T2320-A10

DIFFERENTIAL PRESSURE
CYCLE BYPASS INPUT

RS-232 9 CIRCUIT
MALE CONNECTOR
SEE FIGURE 2

VACUUM FLUORESCENT
DISPLAY (8 CHAR.)
(16 SEGMENT)

REMOTE ALARM
CONDITION OUTPUT
(ALARM VOLTAGE
SOURCE)

4-20mA OUTPUT
ALARM

10.75
10.250

.25
2.325

REMOTE ALARM
CONDITION
INPUT

KEYPAD

2.5 MAX.

BYPASS 4-20mA ALARM
INPUT
OUTPUT
-

.59

.312

+

RS232

OUTPUT

2 POS. SCREW
TERMINAL (7 PL.)

ALARM
INPUT 1

STEP

ITEM

ALARM

VALUE
ALARM
CANCEL

DIFFERENTIAL PRESSURE (DP)
INCHES OF WATER

AUX
OUTPUT
#4

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2320-B10
National Controls
INPUT VOLTAGE:120 VAC, 10VA
Corporation
1725 Western Dr.
Date Code:
West Chicago, IL. 60185 S/N:
PRESSURE
CONNECTIONS:
HI SIDE

.25 DIA. MOUNTING
HOLE (4 PL.)

R

AUX
INPUT
#4
120VAC

R

AUX OUTPUT FOR
EXPANDED MODE OR
AUX REMOTE ALARM
CONDITION OUTPUT
(ALARM VOLTAGE SOURCE)
L1
AUX INPUT
120 VAC
50/60 HZ ALARM OR
EXPANDED
L2

FOR
MODE

LOW SIDE

8.25

8.875

USER HOOKUP
HI SIDE ('DIRTY AIR PLENUM')
AND LOW SIDE ('CLEAN AIR PLENUM
PRESSURE CONNECTIONS
TAPPED 1/8-27 NPT
(2 PL.)
20
19
DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID AN Y WARRANTY

AUX ALARM
INPUTS

18
17

16
15
L1

FUSE

L2

SOL SOL
COM COM

1

2

3

4

5

6

7

8

9

10

11
12
OUTPUTS

13

14

#6 SCREW TERM.
(26 PL. )
.06 THICK
ALUMINUM
MOUNTING PLATE

L1
L2

20 -OUTPUTS TO 120 VAC SOLENOID AIR-VALVES
SOL. COM. TERMINALS ARE INTERNALLY CONNECTEDTO L2 TERMINAL

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-18

DUST COLLECTOR CONTROLS
.16
4 PL.

.31 X .50
MOUNTING SLOT
(4 PL.)

8.0

SEE NOTE 3

OUTPUT
STEP
ITEM

VALUE

ALARM

DIFFERENTIAL PRESSURE (DP)
INCHES OF WATER

National Controls
Corporation

CANCEL

1725 Western Dr.
West Chicago, IL. 60185
RS232
CONNECTOR

National Controls
Corporation
ALARM
INPUT 2

ALARM
INPUT
2

ALARM
INPUT 3

ALARM
INPUT
3

1725 Western Dr.
West Chicago, IL. 60185

S/N:

INPUT

D P OUTPUT (-)

Date Code:

4-20 mA

(+)

PRESSURE CONNECTIONS:
HI SIDE

ALARM
OUTPUT

12.94

MODEL No. DNC-T2310-KIT
INTELLIGENT DUST CONTROL
INPUT: 120 VAC 50/60 HZ
10 VA PLUS LOADS
SOLENOID OUTPUT:
200 VA, 120 VAC 50/60 HZ
ALARM OUTPUT:
3A, 120/240 VAC 50/60 HZ

BYPASS

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-A10
INPUT VOLTAGE:120 VAC, 10VA

AIR CONNECTIONS
1/4" FNPT

ALARM
INPUT
1

LOW SIDE

BLACK INK
SCREENING

DIRTY AIR PLENUM
CONNECTION

CLEAN AIR PLENUM
CONNECTION

L2

SOL
COM

2

1

3

4

5

6

OUTPUTS

7

9

8

4.125
5.625

3AMP

DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID ANY
WARRANTY

L1

10

National Controls
Corporation

ACCESS SCREW
(2 PL.)

SPECIFICATION FOR DNC-T2310-KIT

8708/2/99

1.5

NOTES:
1. DIMENSIONS: INCHES
2. NOT ALL COMPONENTS
ARE SHOWN.
3. 4 MOUNTING FEET AND 4
SCREWS ARE SHIPPED WITH
THE UNIT (NOT INSTALLED).

12 X 10 X 6
FIBERGLASS POLYESTER HINGED
NEMA TYPE 4X ENCLOSURE
WITH CLEAR WINDOW 10.25 X 8.25
ACCESS
SCREW
(2 PL.)

1.5

National Controls
Corporation

A ALARM
INPUT
2

MODEL No. DNC-T2320-KIT
INTELLIGENT DUST CONTROL
INPUT: 120 VAC 50/60 HZ
10 VA PLUS LOADS
SOLENOID OUTPUT:
200 VA, 120 VAC 50/60 HZ
ALARM OUTPUT:
3A, 120/240 VAC 50/60 HZ

ALARM

DIFFERENTIAL PRESSURE (DP)
INCHES OF WATER

B

1725 Western Dr.
West Chicago, IL. 60185

INPUT 1

VALUE

CANCEL

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2320-A10
INPUT VOLTAGE:120 VAC, 10VA

National Controls
Corporation

A ALARM
INPUT
B
3

AUX
OUTP
#4

S/N:

AUX
INPU
#4
120V

Date Code:

DIRTY AIR PLENUM
CONNECTION

8.0

CLEAN AIR PLENUM
CONNECTION

AIR
CONNECTIONS
1/4" FNPT

4.25
5.75

OUTPUT
STEP
ITEM

DIRTY AIR PLENUM
CONNECTION

CLEAN AIR PLENUM
CONNECTION

BLACK INK
SCREENING

20
19

18
17

3AMP

SEE NOTE 3

16
15

L1

L2

SOL SOL
COM COM

1

2

3

4

5

6

7

8

9

10

11
12
OUTPUTS

13

14

12.94

.31 X .50
MOUNTING SLOT
(4 PL.)

8710/2/99

.16
4 PL.

SPECIFICATION FOR DNC-T2320-KIT

Product Overview: The models DNCT2310-KIT and DNC-T2320-KIT are microprocessor-based, 10/20 output sequencer,
reverse air bag house filter controllers. Each
is housed in a NEMA 4X fiberglass enclosure which has a clear window for monitoring the controller’s display. The enclosure
dimensions are 12 inches high by 10 inches
wide and 6 inches deep. The door is hinged

in the left for the 2310-KIT and the bottom
for the 2320-KIT, and can be opened by
loosening two screws located on the side
opposite the hinge.
Air connections are made by mounting to the 1/4-inch NPT female connectors
on the right side of the unit. Connectors
are labeled as DIRTY AIR PLENUM
CONNECTION or the high pressure side of

the filter, and CLEAN AIR PLENUM
CONNECTION which is the low
pressure side of the filter. Holes
must be made in the enclosure to
connect conduit fittings for electrical power to the controller.
For operation of the controls,
refer to specifications on page 4-3.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-19

DUST COLLECTOR CONTROLS

IDC Programming
Tree

RUN
DISPLAY

PROGRAM

Press ITEM Key until "PROGRAM" is Displayed

PROG IDC

PROG I/O

I/O Y (or N)
x=

x=

N

EXIT

Nonchangeable

HOUR xx

MINS xx
x=
x

Nonchangeable

AUX 1

HIGH xxx

LOW xxx

NO CYL x

LOW xxx

ALARM xxx

LO P = xx

ALRMH xx.x

EXIT

HI P = xx

ALRML xx.x

ON = xxx

EXIT

HOUR = xx

E
V
E
N
T
1

x=

Upto 7
On/Off
Events

x=

EXIT

x=

Y

DAY ON.xx

N
HOUR = xx

AUX 2

HIGH xxx

HIGH xxx

LOW xxx

LOW xxx

DIAM xxx

ALRMH xx.x

ALH xxx

HOUR = xx

ALRML xx.x

ALL xxx

MIN= xx

EXIT

EXIT

Nonchangeable

Display Keypad

N

Y

AIRFLW x
ALML = xx.x

DAY OFF.xx

MIN= xx

x=
x

4 - 20 2

MIN = xx

HOUR = xx

4 - 20 #2

ALMH = xx.x

4 - 20 #3

E
V
E
N
T
n

MIN = xx

DAY OFF.xx

BAG TEMP

VALUE

4 - 20 3

ALARM
CANCEL

x=

x=
x

N

x=
EXIT

BAGTMP

Y

x=
x=

EMIS x
x=

Use the  and  Item Keys to navigate
within the Programming Tree. The  Key
moves up the Tree. The  Key moves down
the Tree.

Y

HIGH xxx

CYL DN N (or Y)

OUTPUT
STEP

DAY = xx

DAY ON.xx
x=

N

x=

Use the  and  Value Keys to select
Program Options, or change parameters.
The  Key increments value. The  Key
decrements value

EXIT

EMIS x

OUTPUT = x

ITEM

N

Y

x=

EXIT

EXIT

TIME xx.xx

Non-changeable

4 - 20 1

OFF = xx

N

Y

x=

4 - 20 #1

LAST = xx

x=

CLOCK x

Y

IDENT x

I/O V xxx

EXIT

PROG CLK

Y

ALARH xx.x

HIGH xxx

ALARL xx.x

HIGH xxx

LOW xxx

EXIT

LOW xxx

ALARH xxx

ALRMH xx.x

ALARL xxx

ALRML xx.x

DROP xxx

EXIT

EXIT
Y

N

AUX 1

Nonchangeable

N

ALCK xx.x

If x = N, Display Reports: "ERR AUX 4"
If x = Y, Display Reports: "ERR ALCK"

HOPPER xxx

If x = N, Display Reports: "ERR AUX 5"
If x = Y, Display Reports: "ERR HOPP"

EXIT
EXIT

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-20

DUST COLLECTOR CONTROLS

Intelligent Dust Collector Controller
Remote Input/Output Module
Model DNC-T2300-I/O
FEATURES
● Enhances T2310 and T2320 timer oper●
●
●
●
●
●
●
●
●
●
●
●
●
●

●

ation
Monitors three 4-20 mA analog inputs
Monitors three switched inputs
Monitors one type J thermocouple
Operating temperature range from
-40°C to 65°C
Communicates via RS232 port to intelligent controller
Communicates via 2 wire network to
remote sites
Interconnectable for overall system
management
Large storage capacity for historical
trending of system data
Aids in system diagnostics
Increases overall system efficiency
Conformally coated for protection
against vibration, humidity, and contamination
Metal chassis provided: for mounting
directly into NEMA 4 box
Timer functionally tested to eliminate
field failures
One Year Warranty: warranted to be
free from defects in materials or workmanship for one year from date of
manufacture
File #E65038

non-volatile memory for the storage of
up to one year of input trending data. The
I/O board requires either a T2310 or T2320
Timer to program and operate the board
and a T2300 Display Panel to access data
trending reports.
The I/O board offers significant versatility to the Intelligent Dust Collector Controller
system. It can monitor, display, alert, and
store dust collector system parameters from
pressure sensors, emission monitors, plenum air flow sensors, broken bag detectors,
fan motor current sensors and any other
device which has a 4-20 mA current output
or contact closure output. The unit works
in conjunction with the T2310 and T2320
Timers and also with the DNC-T2300-DSP
Display Panel.
Operating Logic: Upon application of
power to the unit, communication will be
established with the T2310 or T2320 Timer
via the RS232 port. The I/O board can then
be configured for the inputs provided to it
by using the keypad on the controller. Alarm
setpoints and 4-20 mA scaling can be programmed for different types of inputs to be
displayed in a meaningful fashion on the

controller’s 8 character display and
output via the two wire Enhanced
Timer Network to the DNC-T2300DSP remote display panel.
Inputs: There are three general purpose 4-20mA current loop
inputs which are configured by the
Timer. Depending on how the particular 4-20 mA inputs are configured, the messages that appear
on the Timer’s display would either
show a generic range of 0-100%
based on the 4-20 mA input or
data units specific to three pre-programmed sensing devices would
be displayed.
There are two general purpose
switched inputs which will monitor and report up to two contact
closures as alarm conditions to
the Timer, and one contact closure input which allows the user to
place the Enhanced Timer system
in standby mode.

RS-232 Null Modem Cable

Network Connection
to DSP-T2300-010

OUTPUT
STEP

PART NUMBER

105 to 135 VAC

DNC-T2310-A10

210 to 270 VAC

DNC-T2310-A220

ACCESSORY
Enclosure

DIMENSIONS
10” x 8” x 4”

PART NUMBER

ALARM
CANCEL

RS232
CONNECTOR

National Controls
Corporation

1725 Western Dr.
West Chicago, IL. 60185

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA
S/N:

Date Code:

BYPASS
INPUT

PRESSURE
CONNECTIONS:
HI SIDE
ALARM
OUTPUT
ALARM

LOW SIDE

INPUT

DNC-T2300-I/O

DNC-T2310-010

L1

INPUT VOLTAGE

VALUE

3AMP

ORDERING INFORMATION

ITEM

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID ANY
WARRANTY

The Model DNC-T2300-I/O module provides
several functions. It communicates with a
T2310 or T2320 Dust Collector Timer via the
RS232 port to form an Enhanced Timer system, and it communicates pertinent system
data to remote control/display devices via
the 2 wire Enhanced Timer Network. It also
incorporates three 4-20 mA current loop
inputs, three contact closure type inputs,
and one type J thermocouple input. In addition, the I/O board provides 16K bytes of

L2

SOL
COM

National Controls
Corporation

L1 L2

1

2

3
4
5
6
OUTPUTS
Model DNC-T2310-010

7

8

9

10

T2310 & I/O Board Wiring Diagram

BOX-A1008-CHNF

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-21

DUST COLLECTOR CONTROLS
RS-232 9 CIRCUI
T
MALE CONNECTOR

The I/O board also has the capacity to
monitor the temperature of a type J thermocouple in °F, with a range of 40°F to 700°F.

SPECIFICATIONS
INPUTS
Voltages: 105-135 VAC, 50/60 Hz; 210-270 VAC,
50/60 Hz
4-20 mA Current Loops:
Input Impedance: 401.5 ohms +20 ohms
Accuracy: +1% of applied signal.
#1: Emissions/Aux1 (Sink Capability Only)
User Selectable Functions:
Emissions: Output is percent of full scale input
Generic: Output is percent of full scale input
#2: Air Flow/Aux2 (Sink Capability Only)
User Selectable Functions:
Air Flow: Pitot Tube sensing device required,
output range 0 to 6.5 mega SCFM
Generic: Output is percent of full scale input
#3: Manifold/Aux3 (Source or Sink Capability)
Source Voltage: +24v +2v
User Selectable Functions:
Manifold pressure: Output range: 0 to 999 psi
Generic: Output is Percent of full scale input.

.25 DIA. MOUNTING
HOLE (4 PL.)

2 POS. SCREW
TERMINAL (8 PL.)

Switched
Inputs
6.75
6.25

History Trending: The I/O board has the
capability to store data generated by the
Timer connected to its RS232 port as well
as data generated by the various sensing
devices connected to its inputs. Data history is subdivided into three categories: Short
Term History, Long Term History, and Alarm
History.
Short Term History is a time and date
stamped recording of the hourly averages of
the 4-20mA inputs, the Differential Pressure
from the Timer, the highest temperature
recorded, and the number of outputs that
were pulsed in that hour. This Short Term
History period is two weeks, after which
time the oldest 24 hours of recorded data
is averaged along with the highest recorded
temperature and the number of outputs that
were pulsed for that period and is stored in
Long term history.
The Long Term History period is one
year, after which time the oldest recorded
data is discarded to make room for new
data.
Alarm History is event driven, if any
alarm conditions occur, a time and date
stamped “snapshot” of all the system
parameters is recorded in a First-In-FirstOut circular data buffer. This FIFO buffer
can store up to 212 alarm events and is not
time dependent.
In order to generate the Data History
Reports, a DNC-T2300-DSP Remote
Display Panel and a terminal device capable
of communicating standard ASCII via an
RS232 connection are required.

TO
NETWORK
CONNECTION

4-20mA
Inputs
"J" THERMOCOUPLE
Input

2.50 MAX.
.06 THICK ALUMINUM
MOUNTING PLATE

CURRENT LOOP SINK
OR SOURCE SWITCH
(SWITCH SHOWN IN
SINK POSITION)

Input Voltage
50/60Hz
4.250
5.000

RS-232 Null Modem Cable
Wiring Diagram

Switched Inputs:
Alarm Input Open Circuit Voltage: 40 VDC
Alarm Input Short Circuit Current: 4.5 mA
#1: Airlock Fault/Aux4 Alarm: Input will be
labled and recorded as either Air Flow or Aux4
depending on user selection.
#2: High Hopper/Aux5 Alarm: Input will be
labled and recorded as either High Hopper or
Aux5 depending on user selection.
#3: Standby Function: Dedicated as a Remote
Standby Switch Input.
Thermocouple Input:
Thermocouple: Type J
Temp. Measurement Range: -40°F to 700°F
Temp. Measurement Accuracy: +4°F
SERIAL COMMUNICATIONS
Null modem type connection required between
controller and I/O board.
Type: RS232
Mode: 4800 baud, 8-data bits 1-start bit 1-stop
bit, X ON - X OFF, no parity
Function: Dedicated for communication with a
T2300 Series Dust Collector Controller.
Connector: 9-pin male IBM-compatible D-SUB
connector. Null modem type connection required
between controller and I/O board.
Network Connection:
Type: 2 wire twisted pair
Termination: 52.3 ohm, 1%, 1/8 W resistor
Network Connection Device: FTT-10A Transceiver
ENVIRONMENTAL
Operating Temperature Range: -40° to 65°C
Humidity: 90% non-condensing
Environmental Protection: RTV conformal coating for humidity and vibration
Contact factory for additional information

GROUND

1 234 5

1 23 4 5

6 78 9

6 78 9

RS232 CONNECTORS (TOP VIEW)
9-PIN RS232 D-SUB (PLUG) CONNECTOR
MOUNTED ON CONTROLLER
MATES WITH 9 PIN (RECEPTACLE)
CONNECTOR AMP #747150-1 OR EQUIV.
RECEIVE DATA
TRANSMIT DATA
GROUND

1 23 4 5
6 78 9

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-22

DUST COLLECTOR CONTROLS

Intelligent Dust Collector Controller
Remote Annunciator Panel
Model DNC-T2300-DSP
FEATURES
● Remotely monitors up to 255 enhanced
timers

● Communicates via 2 wire network to
enhanced timers

● NEMA 4 front panel access control
● History report generation for 1 year of
system data

● Alarm report generation for over 200
alarm events

● Remote PC connection via RS232 port
● 12 tri-color LEDs for at-a-glance system
status annunciation

● 2 line x 8 character alpha-numeric dis-

play
Monitors two switched inputs
Provides one alarm output relay
Aids in system diagnostics
Use to increase overall system
efficiency
● Operating temperature range from
-40°C to 65°C
● One Year Warranty: warranted to be
free from defects in materials or workmanship for one year from date of manufacture
●
File #E65038

●
●
●
●

Operating logic: Upon application of power
to the unit, communication will be established with the Enhanced Timer Network.
When everything on the network is normal,
all the LEDs will be illuminated green and
the data from the first Enhanced Timer on
the network will be displayed. If no communication is established, then the message NET FAIL will be displayed and the
NETWORK STATUS LED will begin flashing
red to indicate a fault.
Each Enhanced Timer on the network
is programmed with its unique ID number.
When the display is presenting the data
from any Enhanced Timer on the network,
this ID number will be shown as “TIMER
xxx” (with xxx being the ID number) along
with the data on the alpha-numeric display.
The data from any Enhanced Timer on the
network will be presented sequentially in a
scrolling fashion on the alpha-numeric dis-

DNC-T2300-DSP
National Controls
Corporation

Dust Collector
System Status

OUTPUT
STEP

ITEM

VALUE

Yellow - Warning

Red - tFaul

DISPLAY
OPTIONS

ALARM
CANCEL

IIndicators:

Green - Ok

ControllerStatus

D P Alarm

Solenoid Alarm

Auxiliary Alarms

Fan Alarm

Temperature Alar
m

Twisted Pair
Enhanced Timer Network

Network Status

Emmission / Aux1 Alar
m

Airlock / Aux4 Alarm

/ Aux2 Alarm

m
Hopper / Aux5 Alar

Air Flow

Comp. Air / Aux3 Alarm

Diaphragm Faul
t

I/O Status

IDC Board

IDC Board
I/O Board

OUTPUT
STEP

ITEM

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr
.
West Chicago, IL. 60185

VALU E
ALAR M

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

CANCEL

RS232
CONNECTOR

National Controls
Corporation

BYPASS

1725 Western Dr
.
West Chicago, IL. 60185

INPUT

PRESSURE
CONNECTIONS:
HI SIDE

Date Code
:

S/N:

BYPASS
INPUT

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA

PRESSURE
CONNECTIONS:
HI SIDE

Date Code
:

ALAR M

ALAR M

OUTPUT

OUTPUT

ALAR M

LOW SIDE

ALAR M

LOW SIDE

INPUT

INPUT

SOL
COM

1

3

2

5
6
OUTPUTS

4

7

9

8

10

I/O Board

OUTPUT
STEP

Model DNC-T2310-010

ITEM

3

2

5
6
OUTPUTS

4

7

L1 L2

INPUT

3AMP

FAILURE TO COMPLY WILL VOID ANY
WARRANT Y

DO NOT USE SLOW-BLOW OR LARGER SIZE

L1

L2

SOL
COM

National Controls
Corporation

1

2

3

4

5
6
OUTPUTS

7

8

9

10

Model DNC-T2310-010

IDC Board
I/O Board

OUTPUT
STEP

ITEM

VALUE
ALARM

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

CANCEL

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr
.
West Chicago, IL. 60185

BYPASS

L1 L2
STEP

ITEM

VALU E
ALAR M

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

CANCEL

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr
.
West Chicago, IL. 6018
5

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA
Date Code
:

S/N:

BYPASS
INPUT

PRESSURE
CONNECTIONS:
HI SIDE

ALAR M

ALAR M

OUTPUT

OUTPUT

ALAR M

ALAR M

LOW SIDE

INPUT

INPUT

2

3

4

5
6
OUTPUTS

Model DNC-T2310-010

L1 L2

Timer 2

7

8

9

10

Typical Enhanced Timer
Network Connection

3AMP

1

FAILURE TO COMPLY WILL VOID ANY
WARRANT Y

SOL
COM

DO NOT USE SLOW-BLOW OR LARGER SIZE

3AMP

FAILURE TO COMPLY WILL VOID ANY
WARRANT Y

DO NOT USE SLOW-BLOW OR LARGER SIZE

L2

I/O Board

OUTPUT

Timer 3

INPUT

PRESSURE
CONNECTIONS:
HI SIDE

LOW SIDE

National Controls
Corporation

10

Timer 4

ALAR M

LOW SIDE

IDC Board

L1

9

8

Model DNC-T2310-010

PRESSURE
CONNECTIONS:
HI SIDE

Date Code
:

ALAR M

Date Code
:

1

INPUT

OUTPUT

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA

SOL
COM

BYPASS

L1 L2

S/N:

L2

National Controls
Corporation
ALAR M
CANCEL

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr
.
West Chicago, IL. 6018
5

INTELLIGENT DUST CONTROL
0
MODEL NO.: DNC-T2310-01
INPUT VOLTAGE:120 VAC, 10VA
S/N:

L1

VALU E

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

Timer 1

3AMP

L2

National Controls
Corporation

DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID ANY
WARRANT Y

3AMP

FAILURE TO COMPLY WILL VOID ANY
WARRANT Y

IDC Board
L1

I/O Board

STEP

ITEM
ALAR M
CANCEL

INTELLIGENT DUST CONTROL
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA
S/N:

OUTPUT

VALUE

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

DO NOT USE SLOW-BLOW OR LARGER SIZE

The Model DNC-T2300-DSP is a remote
display panel used to monitor and control the parameters of the Enhanced
Timer Network, which consists of 1 to 255
Intelligent Dust Collector Controller and I/O
Board combinations or Enhanced Timers.
The display panel communicates with the
Enhanced Timer Network via a simple two
wire connection over a distance of up to
1.5 miles. Data generated by the Enhanced
Timer Network is presented on a 2 line x 8
character vacuum fluorescent alpha-numeric display. In addition, instantaneous system
status is reported by 12 tri-colored LEDs,
some of which can be user assigned to
monitor specific conditions. The Enhanced
Timer Network monitored by the display can
be interconnected in a variety of ways: in
series, parallel, and/or series-parallel. It is
also possible to have more than one DNCT2300-DSP connected to an Enhanced
Timer Network.

L1

L2

SOL
COM

National Controls
Corporation

1

2

3
4
5
6
OUTPUTS
Model DNC-T2310-010

7

8

9

10

L1 L2

Timer 5

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-23

DUST COLLECTOR CONTROLS
8.0
6.0

ORDERING INFORMATION
INPUT VOLTAGE

PART NUMBER

105 to 135 VAC

DNC-T2300-DSP

210 to 270 VAC

DNC-T2301-DSP

The DNC-T230*-DSP is housed in a NEMA 4 type enclosure ready
for mounting. This enclosure is made of heavy gauge steel and has
a continuous hinge cover. All seams are continuously welded. The
finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.

Dust Collector
System Status

11.5

National Controls
Corporation

OUTPUT
STEP

ITEM

VALUE

DISPLAY
OPTIONS

CANCEL

IIndicators:

Green - Ok

Yellow - Warning

Red - tFaul

C o n t r o l l e r S t a t us

D P Alarm

Solenoid Alarm

Auxiliary Alarms

Fan Alarm

Temperature Alarm

Network Status

Emmission / Aux1 Alarm

Airlock / Aux4 Alarm

Air Flow

Hopper / Aux5 Alarm

/ Aux2 Alarm

Comp. Air / Aux3 Alarm

10.0
10.75

ALARM

Diaphragm Fault

I / O S t a t us

.75

play, for as long as the display is set for that
particular timer. Enhanced Timer selection
is accomplished by accessing the SELECT
TIMER menu item (see programming tree).
If, during the course of normal operation, an alarm occurs on an Enhanced Timer
other than that which is being displayed,
the display will automatically switch to the
Enhanced Timer generating the alarm and
show the alarm condition along with all
other parameters associated with it. Alarm
events are annunciated by the alpha-numeric display along with a corresponding LED
indicator which will begin flashing red until
the alarm condition has been cleared or
until the ALARM CANCEL key has been
pressed.
An additional feature of the display is the
normally open Alarm Output Relay, which
closes on any alarm condition; this output
can be used to switch a signalling device to
alert the user. When an alarm condition is
present, pressing the ALARM CANCEL key
will cause the Alarm Output Relay to open
but keep the Alarm status in effect on the
display and change the flashing red LED to
a steady amber to indicate that the alarm
condition has been acknowledged but has
not yet been cleared.
The six button keypad similar to that
found on the Enhanced Timer can be used
to program parameters or generate History
Reports of any Enhanced Timer on the network (see programming tree for overview).
Programming data is sent over the two
wire network to the respective Enhanced
Timer. History Report data is sent over the
RS232 port on the display to a device which
is capable of displaying and/or storing a
comma delimited ASCII file format. A typical application would be to connect a laptop PC computer’s RS232 port to the display’s RS232 port with a null modem cable

4.3

1.0

.312 DIA. 4 HOLES
RS-232 Null Modem Cable
Wiring Diagram

GROUND

and download a History Report into a file
for later analysis in a spreadsheet program.
Remote access of the display functions is
also available via the RS232 port. Using the
same connection as stated above, a PC can
be used to display all the data provided by
an Enhanced Timer as well as program any
facet of the Enhanced Timer Network.
Among the features of the display is a
battery backed up, 24 hour Day/Date/Year
clock, which maintains the Enhanced Timer
Network time for accurate recording of
History logging and all alarm events for all
of the Enhanced Timers on the network.
Furthermore, two Alarm Inputs are provided
on the display for monitoring general system alarms or whatever the user desires.
The DNC-T2300-DSP is designed to be
used as a central point of control for either
a small or large facility which has multiple
dust collectors or to monitor a dust collector from a remote location. Since the two
wire network utilizes peer-to-peer communication protocol, it is possible to have
more than one display connected to the
Enhanced Timer Network to report the status of different Timers simultaneously.

1 234 5

1 23 4 5

6 78 9

6 78 9

RS232 CONNECTORS (TOP VIEW)
9-PIN RS232 D-SUB (PLUG) CONNECTOR
MOUNTED ON CONTROLLER
MATES WITH 9 PIN (RECEPTACLE)
CONNECTOR AMP #747150-1 OR EQUIV.
RECEIVE DATA
TRANSMIT DATA
GROUND

1 23 4 5
6 78 9

Caution:
1. Do not mount controls in high vibration areas without shock mounts.
2. Do not mount controls in areas of high dust or corrosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the controls, as we employ some very sophisticated components that could be further damaged. For service, call
us directly: 800-323-2593.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-24

DUST COLLECTOR CONTROLS
RS-232 Null Modem Cable
To PC or Terminal
ALARM

SPECIFICATIONS

Remote Alarm
Relay Output

Remote Alarm
Input 2

Alarm Voltage
Source
Network
Connection
to Enhanced
Timer Network

TERMINATIO N

50

100

1
2

INPUTS
Voltages: 105-135 VAC, 50/60 Hz; 210-270 VAC,
50/60 Hz
Switched Inputs:
Alarm Input Open Circuit Voltage: 10 VDC
Alarm Input Short Circuit Current: 13 mA
#1: Display 1 Alarm: Status LED Auxiliary Alarms
#2: Display 2 Alarm: Status LED Auxiliary Alarms
OUTPUTS
Alarm Output
Type: 1-Form A (SPST) relay contact
Rating: 3 A at 120/240 VAC
Display: 2 line x 8 character; alpha-numeric
vacuum fluorescent, .3” high
Status LEDs:
Quantity: 12
Type: Tri-Color; Red-Fault, Yellow-Alarm acknowledged, Green-Normal
Status LED Nomenclature:
dP Alarm
Solenoid Alarm
Auxiliary Alarms
Fan/Alarm 1
Temperature Alarm
Network Status
Emission/Aux 1 Alarm
Airlock/Aux4 Alarm
Air Flow/Aux 2 Alarm
Hopper/Aux5 Alarm
Comp. Air/Aux3 Alarm
Diaphragm Fault
Serial Communications: Null modem type connection required between display and terminal or
PC
Type: RS232
Mode: 9600 Baud, 8-Data Bits,1-Stop Bit, No
Parity
Function: Dedicated For Communication with an
ANSI type VT100 Terminal
Connector: 9-pin male IBM compatible D-SUB
connector null modem type connection required
between display and terminal or PC.
Network Connection:
Type: 2 wire twisted pair
Transmission Line: 2 wire twisted pair (Belden
85102 or 8471 or equiv. recommended)
Termination: 50 or 100 ohm, jumper selectable
resistor
Free Topology: 50 ohm termination on only one
end of the network bus. Remove jumper on all
other bussed units.; Node-to-Node distance
1640.5 ft. max.; Bus Length 1640.5 ft max.
Double Terminated: 100 ohm termination on
each end of the network bus; remove jumper on
all other bussed units; bus length 8858.3 ft max.
Network Connection Device: Echelon FTT-10A
Transceiver
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 70°C
Humidity: 90% non-condensing
Protection: Conformal coat for humidity and
vibration

Remote Alarm
Input 2

L1 L2
Input Voltage

Alarm File Output Format:
IDENTxxx, Year, Month, Day, Hour, Differential
Pressure, Emissions, Airflow, Manifold Pressure,
Bag Temperature, Temperature Probe Failure, Bad
Solenoid, Differential Pressure too Hi/Low, One hour
warmup failure, 5 cleaning cycle alarm, External
alarm input #1, External alarm input #2, External
alarm input #3, External alarm input #4, Triac is
shorted on, 0, 0, 0, 0, 0, 0, High emission, High or
Low airflow, Manifold pressure current loop out of
range, Manifold pressure too low before firing of
the solenoid, Manifold pressure did not drop when
a solenoid fired, High bag temperature alarm, High
hopper alarm, Airlock fault, 0, Bag temperature probe
open, Communication fault, Timer fail, 0, 0, 0, 0, Last
solenoid that fired before the alarm, Solenoid number
that did not fire, Solenoid number which is stuck on,
Last solenoid that fired before alarm input #1, Last
solenoid that fired before alarm input #2, Last solenoid that fired before alarm input #3, Last solenoid
that fired before alarm input #4.
File Output Format:
xxx, xx, xx, xx, xx, xxx, xxxx, xxxxxxx, xxxx, xxxx, x,
x, x, x, x, x, x, x, x, x, 0, 0, 0, 0, 0, 0, x, x, x, x, x, x,
x, x, 0, x, x, 0, 0, 0, 0, 0, xxx, xxx, xxx, xxx, xxx, xxx,
xxx, CR, LF
Short and Long Term Memory File Output Format:
IDENTxxx(1-255), Year (last 2 digits), Month (1-12),
Day(1-31), Hour(0-23), Differential Pressure (in. H2O),
Emissions or AUX1 (percentage), Airflow (SCFM) or
AUX2 (percentage), Manifold Pressure (psi) or AUX3
(percentage), Bag Temperature (°F), Number of
Solenoids that fired.
File Output Format:
xxx, xx, xx, xx, xx, xxx, xxxx, xxxxxxx, xxxx, xxxx,
xxxxx, CR, LF

Contact Factory for Additional Information

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-25

DUST COLLECTOR CONTROLS

DNC Programming
Tree

Operational
Display

When not in Program Mode,
the keypad on the Display
simulates the keypad of the
Timer selected

Press Output Step
& Alarm Cancel Keys
Simultaneously

Select
Timer xxx

Program
Enter

Exit

Version

History

DisplayD
Ver xxx

History
Short

Sending
Short

DisplayL
Ver xxx

Clock
Year xxx

History
Long

Sending
Long

I/O
Ver xxx

Clock
Month xxx

History
Alarms

Sending
Alarms

DSP
Ver xxx

Clock
Date xxx

History
Exit

Clock

Display Keypad
OUTPUT
STEP

ITEM

VALUE

Menu
Exit

DISPLAY
OPTIONS

ALARM
CANCEL

Use the  and  Item Keys to navigate
within the Programming Tree. The  Key
moves up the Tree. The  Key moves down
the Tree.
Use the  and  Value Keys to select
Program Options, or change parameters.
The  Key increments value. The  Key
decrements value

Version
Exit

Clock
Day xx

Clock
Hour xx

Clock
Minuite xx

Clock
Exit

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-26

DUST COLLECTOR CONTROLS ACCESSORIES
OFF

1.563
1.953

On/Off Switch

ON

ORDERING INFORMATION
NEMA 4 Rated On/Off Switch
with Legend Plate

MSW-0DPST-011

REQUIRES 1.187 DIAMETER
MOUNTING HOLE

2.75

1.25
1.594
(4572-7)

MSW-0DPST-011

1.578

Pilot Lamp
ORDERING INFORMATION
NEMA 4 Rated Pilot Lamp

ASL-00RED-NEMA 4
2.062

REQUIRES 1.187 DIAMETER
MOUNTING HOLE

1.25
1.65

ASL-00RED-NEMA4

(4572-6)

1

4

5

8

Relay

12
14

RESET

KDD-LATCH-120AC

ORDERING INFORMATION
KDD-LATCH-120AC

1.10

Alternate Action Dual Coil Latch
Relay

11
SET

10

9
13

1.42

1

7

6

5

ORDERING INFORMATION
Socket for Latch Relay

2.83

Socket

2

2.32

8

3

.85

.25

MSO-0D11P-012
12

11 10

4

14 13

9

.87
Terminal Arrangement

1.16

Mounting Holes
MSO-011DP-012

.65
1.18

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

4-27

DUST COLLECTOR CONTROLS ACCESSORIES
6.0
1.0

4.0

3.8

Enclosures

10” x 8” x 4” NEMA 4 Enclosure,
Steel

BOX-A1008-CHNF

12” x 10” x 5” NEMA 4
Enclosure, Steel

BOX-A1210-CHNF

14” x 12” x 6” NEMA 4
Enclosure, Steel

BOX-A1412-CHNF

12” x 10” x 6” NEMA 4X Window
Enclosure, Fiberglass

BOX-A1210-CHSC
.75

8.75

BOX-A0806-CHNF

8.0

8” x 6” x 3.5” NEMA 4 Enclosure,
Steel

9.5

ORDERING INFORMATION

(4570-2)

.312 DIA.
4 HOLES

BOX-A0806-CHNF

8.0

10.0
5.3

12.0

11.5

.75

.75

10.75

1.0

12.75
13.5

8.0

4.3

1.0

10.0

6.0

.312 DIA.
4 HOLES

.312 DIA.
4 HOLES

(4570-3)

(4570-4)

BOX-A1210-CHNF

BOX-A1008-CHNF

10.50"
8.0"

6.3

.16"
4 PL.

.75

12.94"

.6.25"
.31" X .50"
MOUNTING SLOT
- 4 PL. (8 X 13)

12.50"

1.0

14.0
14.75
15.5

12.0
10.0

.312 DIA.
4 HOLES

(4570-5)

BOX-A1412-CHNF

ACCESS SCREW (2 PL.)

BOX-A1210-CHSC

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

Notes

5-1

In addition to our Solid State Relay offering,
AMETEK NCC provides a reliable, low cost
means to monitor line voltage parameters in
both single phase and 3 phase applications as
well as over/under current monitoring of up to
20 A. Costly motor damage as well as sensitive equipment malfunction can be averted
with the use of these line monitors which will
steadfastly guard against low voltage and
improper phase conditions.
In addition, at AMETEK NCC offers impressive
factory back-up support, and our parts inventory and product availability are unsurpassed.
With over 250 stocking distributor outlets,
serious downtime problems can virtually be
eliminated. Technical assistance for design
and engineering help is readily available
through our toll free number: 800-323-2593.

Common Applications:
●
●
●
●
●
●
●
●
●

3 Phase Motor Protection
Compressor Brown Out Protection
Elevator Protection
Industrial Wastes Pump Monitor and
Control
Deep Well Pump Protection
Large Incandescent Lamp Load Control
Frequent Switching of Large Loads
Motor Overload Protection
Broken Drive Detection

SOLID STATE RELAYS, VOLTAGE
MONITORS, CURRENT MONITORS

AMETEK NCC offers a full line of Solid State
Relays capable of switching from 10 to 75 A
at up to 330 VAC 50/60 Hz. These rugged,
encapsulated controls are ideal for use in
applications which require a frequent switching rate and/or a high current inrush rate.
Particularly, large tungsten lamp loads or
motor loads are well served by solid state
switching devices, as there are no moving
parts to arc over and wear out. The reliability
of AMETEK NCC’s Solid State Relays has
been time-tested in industrial environments
throughout the world.

5-2

SOLID STATE RELAYS

Solid State Power Relays

The AMETEK NCC Series of Solid State
Power Relays provide a highly reliable
means of switching a variety of AC loads up
to 20 A. Snubber circuitry is included with
each unit for high dV/dt applications and
inductive loads.
Use of rugged output devices provides
significant increases in turn-on surge capability. Two input control voltage ranges are
available in either Form A (SPST-NO) or
Form B (SPST-NC) output configurations.

1.75
(44.5)
1.10
(27.9)

.30
(7.6)

ALL MODELS
Max. Load Current*: 25 A
Max. Peak Transient Voltage: 600 Vpk
Output Voltage Range: 48-300 VAC
Max. Off State Leakage Current: 7.2 mA at
300 VAC (RMS)
Operating Temp. Range: -40 to 80 °C
Storage Temp. Range: -40 to 65 °C
Dielectric Strength at 60 Hz
Between Input/Output: 4000 VAC (RMS)
Between Input/Base: 2500 VAC (RMS)
Between Output/Base: 2500 VAC (RMS)
Max. Surge Current: 370 arms, 8.3 ms
Min. Off State dV/dt (static): 500 V/µS
Thermal Resistance Junction to Case
(Point A): 1.3°C/W Tj max.=110 °C
Turn On Type: Random
SNC-R2025-507 AND SNC-R2025-517
Max. On State Voltage Drop:1.5 VAC (RMS)
Input Impedance: 1700 ohms ±5%
Turn Off Voltage: 2 VAC/DC min.
Turn On Voltage: 3 VAC/DC max.
Output Form:
SNC-R2025-507: SPST-NO
SNC-R2025-517: SPST-NC
Control Voltage Range: 3-30 VAC/DC
SNC-R2025-501 AND SNC-R2025-511
Max. On State Voltage Drop: 1.65 VAC (RMS)
Input Impedance: 56 Kohms ±5%
Turn Off Voltage: 30 VAC/DC min.
Turn On Voltage: 70 VAC/DC max.
Output Form:
SNC-R2025-501: SPST-NO
SNC-R2025-511: SPST-NC
Control Voltage Range: 70-140 VAC/DC

CSA certified file #LR701222
100% functionally and surge tested
24 to 330 VAC load voltage
4000 V isolation
Optically coupled
Epoxy filled
Capable of being switched by a single
CMOS gate
● Built in snubber
● Capable of switching inductive loads of
0.5 power factor
● UL recognized component file
#E164906

1.70
(43.2)

SPECIFICATIONS

●
●
●
●
●
●
●

2.25
(57.1)
1.875
(47.6)

FEATURES

.19
(4.9)

Model R2025

8-32 THRD
WITH SADDLE
CLAMP

.55

24-330 VAC
1
2
LINE 40 AMP WITH HEATSINK LOAD
NORMALLY OPEN

.25 R
2 PLCS

.187 DIA.
2 PLCS

OUTPUT

MODEL No:
SNC-R2040-502
SOLID STATE
RELAY
INPUT
3-32 VDC
3 (+)

National Controls
Corporation
R

(-)

4

.50

POINT A

.53
(13.5)
6-32 THRD
W/ SADDLE
CLAMP

1.00
(25.4)

#8-32
2 PLCS

* See derating curves for proper heat sink requirements

#6-32
2 PLCS
POINT A

.12

.77
1.0 MAX
(25.4)

MOUNTING SURFACE

ORDERING INFORMATION
INPUT VOLTAGE

OUTPUT CONFIGURATION

3 to 30 VAC/DC

PART NUMBER

Normally Open, 25 A

SNC-R2025-507

7 to 140 VAC

Normally Open, 25 A

SNC-R2025-501

3 to 30 VAC/DC

Normally Closed, 25 A

SNC-R2025-517

7 to 140 VAC

Normally Closed, 25 A

SNC-R2025-511

ACCESSORY
Heatsink, .9 °C/W, supplied with Thermal Compound and Mounting Hardware

PART NUMBER
ASY-HS25A-011

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

5-3

SOLID STATE RELAYS

Heat sinks for derating curves are 1/8” thick
aluminum with thermal compound between
the mounting surface and solid state relay
mounting plate.

15

Max. Allowable Mounting Surface Temp. (C)
(Measured at Point A)

Heat Sink Data

Load Current (amps RMS)

25

"x
15
"(4
10
"x1
50
sq
6"( 0"(2
. in
72
0
sq. 0 sq
.) H
in.) . in
EA
.
)
HE
TS
H
E
AT
IN
SINAT S
K
K INK

6"x

20
15
10

NO HE

AT SIN

5
0

20

30

40

50

K (FRE

60

Ambient Temp. (C)

E AIR)

70

80

80
60
40
20
0

0

5

10

15

20

25

Load Current (amps RMS 60Hz)

4.312
2.156

2.155

2.625

1.875

5.625 – .031

.625 TYP

1.875 –.031

.187 DIA

3.935

.40 TYP

.093

.187 TYP

.312 TYP
2.375
4.75

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

5-4

VOLTAGE MONITORS

3-Phase Voltage Monitor
Model 240T6

Adjustment: Apply 3-phase power within operating range to the monitor (phase
sequence must be observed). Turn adjustment to maximum clockwise position.
Indicator lamp will be illuminated red after
the delay time. Slowly turn counterclockwise until indicator changes to green (relay
will activate). If voltage is nominal, setting
should be correct.
Note: If phase sequence is incorrect, the monitor will not activate.
Reverse any two input leads and readjust as described above.

HI

LINE
VOLTAGE

Green
Normal

Red
Fault
Yellow
Fault
Delay

TRICOLOR LED

NATIONAL CONTROLS
CORPORATION
WEST CHICAGO, IL. 60185

3 PHASE VOLTAGE MONITOR
MODEL: PLC-240T6-44T
INPUT VOLTAGE: 160-240 VAC
3 F, 60 HZ

R

R

2.935
(74.5)

8

1.770
(45.0)
FB

FC

FA

4

5
6
7

2
1

VOLTAGE RANGE

PART NUMBER

160 to 240 VAC

PLC-240T6-44T

ACCESSORY

PART NUMBER

8-pin circular socket, DIN rail
mountable

2.400
(61.0)

6
1

3

ORDERING INFORMATION

.522
(13.26)

3.650 MAX
(93.0)

7

Operating Logic: This control continuously
monitors 3-phase power lines for abnormal
conditions. When properly adjusted, the
control will detect:
● Phase loss on a loaded motor, regardless of regenerated voltage
● Low voltage on all phases
● Very low voltage or loss of any single
phase
● Phase reversal
If none of the above conditions are present,
the control will energize the internal relay
and the indicator light will be green. When
any of the above faults are detected, the
indicator light will turn yellow for approximately 3 seconds warning that the relay is
about to de-energize. After the delay time
the relay will de-energize and the indicator
light will turn red. When the fault is corrected, the monitor will automatically reset by
energizing the relay and the indicator lamp
will be green. Should the fault be corrected
during the delay time, the monitor will not
de-activate the relay and the indicator will
again be green.

LO

4

●
●
●
●

5

SETPOINT
Adjustment: Single turn potentiometer for adjusting nominal voltage
Range:
160-240 VAC 60 Hz LO to HI
180-240 VAC 50 Hz LO to HI
Accuracy:
Min. Setting (Max. CCW): Must operate (green
light) at 160 VAC, 60 Hz (180 VAC, 50 Hz) line to
line
Max. Setting (Max. CW): Must drop out (red light)
at 240 VAC 50/60 Hz line to line
Hysteresis: 2% typical
Fault Delay Time: 2 to 4 sec.
INPUT
3 Phase Operating Voltage: Three wire connection, no neutral required
160-240 VAC, 277 VAC max. line to line 60 Hz
180-240 VAC, 277 VAC max. line to line 50 Hz
Power Consumption: 3 W max. at 277 VAC line
to line exclusive of load
Frequency: 50/60 Hz
OUTPUT
Contact Type: Relay SPDT (1 form C)
Rating: 10 A max. resistive, 1/3 hp, 345 VA,
120/240 VAC
Life:
Mechanical: 10,000,000 operations
Full Load: 500,000 operations
Display: 1 tricolor LED
Green indicates status OK
Yellow indicates fault condition imminent
Red indicates fault condition
PROTECTION
Transient Voltage: protected by three 30 joule
metal oxide varistors
Dielectric Breakdown: 1500 V RMS minimum at
60 Hz between input and outputs and between
outputs
MECHANICAL
Termination: 8-pin plug
Mounting: Socket mount, part number
MSO-0008P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C
Operating Temperature: -23°C to 55°C

100% functionally tested
Low cost
Tri-color status LED
3 second fault delay timer
Line voltage setpoint adjustment range:
160 VAC to 240 VAC
50/60 Hz operation
SPDT 10 A relay output
Convenient plug in package
File #E59090

2

SPECIFICATIONS

●
●
●
●
●

3

FEATURES

8

CONTACTS:
10AMP,1/3HP,345VA,
120/240VAC

PIN CONFIGURATION

MSO-0008P-012

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

5-5

VOLTAGE MONITORS

Single-Phase Undervoltage Monitors
Models 120AZ and 240AZ

SPECIFICATIONS

● 100% functionally tested
● Form C relay output
● On-board Trimpot for setpoint adjust-

INPUT
Operating Voltage Ranges:
Model 120AZ: 0 to 132 VAC 50/60 Hz
Model 240AZ: 0 to 264 VAC 50/60 Hz
Max. Power Consumtion:
Model 120AZ: 2.6VA at 132 VAC
Model 240AZ: 4.5VA at 264 VAC
CONTROL
Adjustment: On-board Trimpot
Undervoltage Setpoint Range:
Model 120AZ: 78 to 99 VAC
Model 240AZ: 156 to 99 VAC
Reset Point Voltage:
Model 120AZ: 104 VAC
Model 240AZ: 209 VAC
Repeatability: ±0.5% for fixed conditions; ±1%
over temperature range
Voltage Sense Accuracy: ±2% at 25°C
Power Off Reset Time: 150 ms max.
OUTPUT
Type: Relay contacts, SPDT (1 form C)
Rating: 8 A max. resistive at 250 VAC and
30 VDC; 100 mA at 5 VDC minimum load current
Indication: Green LED; ON for normal condition
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Dielectric breakdown: 3000 Vrms terminal to
mounting1500 Vrms input to output
Insulation resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x.032” male fast-on terminals
Mounting: Surface mount with one #8 screw
Life:
Mechanical: 10,000,000 cycles min.
Electrical: 100,000 cycles min.
ENVIRONMENTAL
Storage temperature: -40°C to 85°C
Operating temperature: -23°C to 55°C
Humidity: 95% relative max.

ment
Circuitry completely encapsulated
Low cost protection against brownouts
Compact size
Superior transient protection
Flame-retardant and solvent-resistant
polyester thermoplastic housing
●
File #E65038

●
●
●
●
●

LOGIC FUNCTION DIAGRAM
Maximum Input Voltage

Reset Point
Undervoltage
Setpoint Range

Set
Point

0 Volts

Output Relay On
and LED
Off

The 120AZ and 240AZ voltage sensors
are intended for use as protection devices
for electronic equipment in the event of a
brown out condition.
Operating Logic: When the input voltage to
the module is greater than the Reset Point
voltage, the relay will be energized and the
LED will be illuminated indicating a normal
line voltage condition. If, however, the input
voltage drops below the Setpoint Voltage
selected by the potentiometer, the relay will
de-energize and the LED will turn off. The
module will remain in this state as long as
the input is less than Reset Point voltage.

UNDERVOLTAGE SETPOINT
ADJ USTMENT ACCESS
NORMAL VOLTAGE
INDICATOR (GREEN LED)

95
90

Voltage
Normal

85
78
99
UNDERVOLTAG
E
SETPOIN
T

2.OO SQ.

FEATURES

N.O.

N.C.

National Controls
Corporation
West Chicago, IL.
60185

E65489

C

R

R

COM.

UNDERVOLTAGE DETECTO
R
Model No: VNC-120AZ-341
Range: 78-132 VAC, 2.6 VA
Contacts:
8 AMP, 1/3 HP, 120/240 VAC
50/60 HZ

Input

INPUT
VOLTAGE

CLEARANCE HOLE
FOR #8 SCREW
5659/12/94

.885
1.25 MAX
(31.75 mm)
.250 X .032 MALE
SPADE TERMINAL
(5 PL. )

ORDERING INFORMATION
INPUT VOLTAGE RANGE

UNDERVOLTAGE SETPOINT RANGE

RESET POINT VOLTAGE

PART NUMBER

0 to 132 VAC 50/60 Hz

78 to 99 VAC

104 VAC

VNC-120AZ-341

0 to 264 VAC 50/60 Hz

156 to 199 VAC

209 VAC

VNC-240AZ-345

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

5-6

CURRENT MONITORS

2-20 A Current Monitor
IST-200T Series
FEATURES
●
●
●
●
●
●
●
●
●
●
●
●

100% functionally tested
Low cost
Fault status LED
Adjustable trip delay timer
Adjustable trip point from 2 to 20 A
Selectable ouput modes:
– Latching
– Non-latching
Selectable sensing modes:
– Over-current
– Under-current
120 VAC and 240 VAC models
50/60 Hz operation
SPDT 10 A relay output
Epoxy encapsulated
File #E59090

Operating Logic: The Current Monitor
senses AC load current passing through its
torroid transformer. In the OVER-CURRENT
mode, the on-board relay will initiate the
TRIP DELAY timer and illuminate the FAULT
LED when the sensed current is greater
than the TRIP POINT setting. If the sensed
current is still greater than the TRIP POINT
setting after the TRIP DELAY timer has
elapsed, the on-board relay will energize.
If the UNDER-CURRENT mode is selected, the on-board relay will be un-energized
as long as the sensed current is greater
than the TRIP POINT setting. Once the
sensed current drops below the TRIP POINT
setting, the TRIP DELAY timer will start timing and the FAULT LED will illuminate. If the
sensed current is still less than the TRIP
POINT setting after the TRIP DELAY time
has elapsed, the on-board relay will energize and its contacts will change state.
The Current Monitor will automatically
reset itself when the sensed current returns
to its non-fault value if the NON-LATCH
mode is selected. However, if the LATCH
mode is selected, the on-board relay will
remain energized regardless of any subsequent change in the sensed current. To
reset the fault in this mode, either remove
input power from unit and reapply it, or
switch to NON-LATCH mode.
The Current Monitor is designed to sense
a range of 2 to 20 A with a single loop of the
load wire passed through the torroid transformer. Greater sensitivity can be achieved
by passing multiple loops of the load wire

through the torroid transformer; two
turns would change the range to 1 to
10 A, four turns would change it to 0.5 to
5 A.
TYPICAL APPLICATION

As long as the operating current of the
motor is less than 10 A, the alarm will not
sound. If the motor draws greater than 10 A
for longer than 4.5 seconds, the FAULT LED
will light and the alarm will sound. Because
the NON-LATCH mode is set, the fault condition will clear as soon as the current draw
of the motor drops below 10 A. When the
fault is cleared, the FAULT LED will turn off
and the alarm will stop sounding. If, however, the LATCH mode was selected and
an OVER-CURRENT fault is detected, the
fault will not clear when the motor current
draw dropped below 10 A. In this case, the
alarm would continue to sound until reset of
the Current Sensor by either removing and
reapplying power or by switching to NONLATCH mode.

MOTOR
NONLATCH

LATCH

UNDER
CURRENT

OVER
CURRENT

MODE SELECT SWITCH

Motor
Supply

AC CURRENT SENSOR

min.

max.

Voltage

L1

TRIP
DELAY

L2
min.

COM

max.

TRIP
POINT

NO
FAULT

NC

SETTINGS:
TRIP POINT: approx. 10 amps
TRIP DELAY: approx. 4.5 sec.
MODE SELECT SWITCH:
Non-Latching
Over-Current

ALARM

120 or 240 VAC
Input Voltage

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

CURRENT MONITORS

SPECIFICATIONS

MOUTING HOLES (2)
.188 DIA.
NONLATCH

LATCH

UNDER
CURRENT

OVER
CURRENT

1.375
MAX.

MODE SELECT SWITCH

AC CURRENT SENSOR
.375 DIA.

2.94

National Controls
Corporation
West Chicago, IL. 60185
min.

Model: IST-200T*-14* INPUT:***VAC
Range: 2-20 AMPS, .*-** seconds

max.

TRIP
DELAY

CONTACT RATING: 10A, 250VAC

L1
L2

min.

TERMINALS ARE
QUICK CONNECT (5)
.25 X .032

COM

max.

TRIP
POINT

NO
FAULT

.28

3.50

INPUT
Operating Voltage:
IST-200TA-141: 105 to 135 VAC, 50/60 Hz
IST-200TA-145: 210 to 270 VAC, 50/60 Hz
Power Consumption: 3.5 VA max.
Current Sense Input: 0 to 40 A steady-state
200 A inrush for 100 ms max.
OUTPUT
Type: Relay contacts SPST (1 form C)
Rating: 10 A resistive, 1/2 hp at 250 VAC
Life:
Mechanical: 1,000,000 operations
Electrical: 100,000 operations at full load
CURRENT SENSE ADJUSTMENT
Range: 2 to 20 A with single load wire through
sensor, Trimpot adjustable
Power-up surge delay: 100 ms max.
Response time: 100 ms max. over or under current mode
CURRENT TRIP DELAY ADJUSTMENT
Range: 0.1 to 10 sec., Trimpot adjustable
MECHANICAL
Termination: 5 - .25” x .032” male fast-on
terminals
Mounting: 3.5” x 2.5” encapsulated enclosure
with 2 mounting holes suitable for #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to +85°C
Operating Temperature: -40°C to +65°C

5-7

NC

R

MADE IN THE U.S.A

.

.50 [12.7]

.28
1.94
2.50

ORDERING INFORMATION
INPUT VOLTAGE

TRIP POINT

TRIP DELAY

PART NUMBER

120 VAC

2 to 20 A

.1 to 10 sec.

IST-200TA-141

240 VAC

2 to 20 A

.1 to 10 sec.

IST-200TA-145

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

Notes

AC (Alternating Current) An electric current that
reverses direction in a circuit at regular intervals.
Accuracy The variation between the specified delay
time and the Actual Time value, given in percent of
specified delay. [(Actual Time – Specified Delay Time)
/ Specified Delay Time)] x 100.
Actual Time The actual delay of a given device with
sufficient OFF time to input voltage to permit full
recovery of the timing interval. The resulting average
of a group of consecutive time delay readings (excluding the first) may be used to determine the Actual
Time. Five cycles should be considered adequate for
the determination.

Ampere (Amp) The basic unit of electric current.
Arc A luminous discharge of electric current crossing
a gap between two electrodes either through the air
or over an insulated surface. It is deleterious to electromechanical switches, limiting contact life.
Break The moment and/or location at which a series
circuit is opened and made discontinuous.
Brownout A condition in which the supply voltage is
insufficient to power the load.
Circuit A closed path followed or capable of being
followed by an electric current.
Closure The moment and/or location at which two
contacts meet to complete a circuit.
Conductor A substance or medium that conducts
heat, light, sound, or especially an electric current.
Contact Chatter (Contact Bounce) Occurs when
an electromechanical switch is in the process of making connection in a circuit; for a brief time period,
the contacts will bounce together until they are fully
seated.

Delay on Make (Delay On Energize, On Delay) A
particular type of time function which delays the ON
event upon initial application of power to the timing
device.
Dielectric Breakdown The voltage potential at which
the insulating properties of a non-conductor will break
down and conduct current. Measured in Kilovolts.
DC (Direct Current) An electric current flowing in one
direction (constant polarity), as opposed to Alternating
Current.
DPDT (Double Pole Double Throw 2 Form C
Contacts) A type of contact configuration which consists of two isolated sets of contacts operating simultaneously. Each contact set consists of a Common
contact, Normally Open contact, and a Normally
Closed contact. In relay nomenclature, the states of
the contacts are given with the relay coil unenergized.
Electricity A basic phenomenon in nature which
involves the movement of electrons in a medium. This
movement of electrons or electric current is considered
a source of power.
Electromotive Force (EMF) Difference in electrical
potential measured in volts.
Encapsulant A compound, typically epoxy or silicone
elastomer, used to envelop and seal components in an
electronic circuit.
Energize To apply power to a device.
External Adjustment A remotely located component
or device which is used to alter an input or output
parameter on a controller.
Factory Calibration To adjust a controller during the
manufacturing process to specific points in order to
meet the operational specifications.

Contacts Electromechanical components that make
or break a connection between two conductors that
permit a flow of current.

Factory Fixed Fixing a particular control parameter
during the manufacturing process to make it nonadjustable in the field.

Controller A regulating mechanism, as in an electric
device used to control a particular process based on
input parameters.

Frequency The number of repetitions within a given
time of a complete wave form, as of common line
voltage with typical frequencies of 50 or 60 cycles per
second. See Hertz.

CSA Canadian Standards Association (Testing
Laboratory for products sold in Canada.)
Current The amount of electric charge moving in a
conductor past a specified circuit point within a given
time. The basic unit is the ampere.
Cycle A single complete execution of a periodically
repeated event or a periodically repeated sequence
of events.
De-energize To remove power from a device.
Delay To postpone an event until a later time.

6-1

Full-wave Rectified AC Alternating Current changed
to Direct Current utilizing both the positive and negative portions of the AC sine wave.
Ground The point of an electric circuit that is at a zero
volt potential with respect to the earth.
Guaranteed Range The range of operation of a controller or controlled parameter which the manufacturer
specifies reliable consistent operation.
Half-wave Rectified AC Alternating Current changed
to Direct Current utilizing only the positive or negative
portion (not both) of the AC sine wave.

GLOSSARY

Ambient Temperature Temperature of the air which
encircles an object.

Delay On Break (Off Delay) A particular type of timing function whereby the OFF event is delayed after a
start circuit is opened.

6-2

GLOSSARY

Heat Dissipation Because all electrical
devices offer resistance to the flow of current, heat is generated when current flows
through this resistance. This undesired
heating effect is a function of the device
resistance and the amount of current flowing through it. Heat sinks are used to cool
high current devices, thereby dissipating
the heat generated.
Heat Sink A device which possesses low
thermal resistance in order to effectively
absorb and dissipate heat.
Heat Sink Compound A compound
used to assure good thermal connection
between a heat dissipating device and a
heat sink.
Hertz A unit of frequency named after
Heinrich R. Hertz (1857-1894) which is
equal to one cycle per second.
Holding Current In solid state switching devices there is a point at which the
current flow is insufficient to maintain conduction. Holding current is specified as
the minimum current through the device,
across the operating temperature range,
that will maintain conduction.
Horsepower (hp) A unit of power in the
U.S. Customary System, equal to 745.7
watts or 33,000 foot-pounds per minute.
Electrical motors are rated in horsepower,
so accordingly, devices designed to control motors are also rated in horsepower.
Humidity Water vapor content in the
air. In percent Relative Humidity, it is a
measurement of the actual water vapor
content of a unit volume relative to what
the maximum amount of water vapor the
same volume can contain at a given temperature.
Hysteresis The failure of a property that
has been changed by an outside force to
return to its original value when the cause
of the change is removed. Some hysteresis is designed into controller circuits
because it prevents noise from causing
false triggering.
Incandescent Load From a switching
perspective, the incandescent load represents an initial inrush current of up to 10
times the steady state rating.

Inductive Load An inductive load
opposes any change to circuit current.
Devices such as motors, solenoids, relay
coils, valves, and contactor coils are all
inherently inductive loads. The current
waveform is always lagging the voltage
waveform in an inductive load; because
of the phenomena, certain factors must
be taken into account when working with
this type of load. An inductive load can
exhibit an inrush current of up to 5 times
its normal running or steady state current
when energized. When power is removed
from the inductive load, high voltage transients are generated due to the collapsing
magnetic field, and this can cause arcing
across contacts or a malfunction, and/or
damage to electronic circuits.
Initiate Time (Start Time) The minimum
time of a switch closure or voltage pulse
applied to a start switch input of a controller which will activate the control function.
Input Voltage The voltage source applied
to the controller input terminals which is
used to power the controller while it is
performing its function.
Inrush Current The peak value of current which a load requires when first being
energized. Certain types of loads (e.g.,
lamps, motors) will draw a larger initial
current because their impedance is lower
at startup than during steady state operation.

Life A specific number of operations or
amount of time during which a particular
device is expected to operated reliably.
Line Frequency Frequency of electrical
service provided by local utility, typically 50
or 60 Hertz.
Line Voltage Initiation The initiation of a
control function by application of line voltage to either the controller’s input terminals or start switch terminals.
Line Voltage Nominal voltage of electric
service provided by local utility, typically
120 or 240 VAC.
Load Any device which consumes power
to do work.
Load Rating A specification of the output capability of a particular controller.
Typically parameters for load rating are:
controllable current range, maximum AC
and/or DC voltage, horsepower or Power
Factor and maximum inrush current.
Lock Shaft (Locking Bushing) A
mechanical means to inhibit further adjustment of a rotary type device such as a
potentiometer.
Low Voltage Voltage which is typically
less than 30 Vrms.
Magnal Plug A circular, 11-pin male connector with an indexing key for proper
orientation in the mating socket.

Isolation No electrical connection
between two or more circuits.

Make A term used to denote the action of
completing an electrical circuit.

Insulation Resistance The degree of
non-conductance of an insulator, measured in Megohms.

Interval A period of time between events.

Metal Oxide Varistor (MOV) A device
whose impedance decreases dramatically
when subjected to voltages greater than
the rated clamping voltage. It is typically
placed in parallel with the input and/or
output of a switching device to effectively
clamp transient voltage spikes to a certain
level.

Kilohm One thousand ohms (1,000 or 1
K ohms).

Megohm One million ohms (1,000,000 or
1Meg ohms).

Leakage Current The maximum current
which a solid state device still conducts
when in the OFF state. Leakage current is
usually measured in milliamperes (mA).

Micro A metric prefix which is used to
multiply a standard unit by 10-6

Insulator A material that insulates, particularly a nonconductor of electricity, heat,
or sound.

LED Light Emitting Diode, used in information displays and as status indicators.

Milli A metric prefix which is used to multiply a standard unit by 10-3
Milliamperes One-one thousandth of an
ampere (.001 or 10-3 ampere).

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

GLOSSARY
Ms One one-thousandth of a second
(.001 or 10-3 second).
Minimum Load Current For electromechanical contacts, it is the minimum
current the contacts will reliably switch
without the contact resistance contributing a substantial error in the circuit. See
Holding current.
Mode of Operation Logical function of a
controller based on input parameters.
Momentary Initiation The initiation of a
controller cycle by a start pulse of shorter
duration than the complete cycle. The initiation could be with a momentary contact
closure or voltage pulse.
Momentary Loss of Power A short
removal of input power to the controller or
controlled circuit. See Brownout.
Momentary Switch A spring loaded
set of contacts, that when the actuator
is pressed, the contacts either close or
open depending on contact configuration.
When the actuator is released the contacts will resume their normal state.
MOV Metal oxide varistor.
Noise An undesirable electrical phenomenon which is generated by various means
(e.g., switching large loads, light dimmers,
electrical storms). This phenomenon
consists of random voltages and currents
induced into electrical circuits, if severe
enough, erratic operation of these circuits
can result.
Nominal Voltage The middle point of
two extremes of voltage as defined by the
tolerance.
Normally Closed Contact (NC) The
condition or position of a particular contact with respect to a common contact
in its normal or quiescent (unenergized)
state. A normally closed contact represents a closed circuit.
Normally Open Contact (NO) The condition or position of a particular contact
with respect to a common contact in its
normal or quiescent (unenergized) state. A
normally open contact represents an open
circuit.
Octal Plug A circular 8-pin male connector with an indexing key for proper orientation in the mating socket.

Offset A fixed difference between the
controller setpoint and the actual control
point of a system under stable operating
conditions.
Ohm A unit of electrical resistance and
impedance named after Georg S. Ohm.
A conductor has a resistance of one
ohm when a current of one ampere flows
through it with a potential of one volt
across its terminals.
ON/OFF Time Ratio The ratio of ON time
to OFF time specified as a fraction or percentage of the total period.
On State Voltage The voltage measured
across a solid state output device when it
is in the ON state. For all practical considerations the value is the same for Peak or
RMS measurements. NOTE: The portion
of the sine wave before the solid state
device turns ON is not to be included in
this measurement.
Operating Temperature The range of
ambient temperature in which a controller
is designed to operate within its specifications. May be stated in Fahrenheit or
Celsius.
Operating Voltage The range of input
voltage within which a controller is
designed to operate. Usually, it is stated
as a nominal value with a maximum and
minimum tolerance (e.g., 120 VAC +10%).
Optical Isolation Utilizing light to isolate
one control circuit from another; mainly
used to safely interface a low level control
signal with a high power output, as in a
solid state relay.
Output The result delivered by a circuit or
device. Also, the terminal or other location
where such result is delivered.
Parallel A type of circuit connection in
which loads are connected side by side
across a common voltage source.
Phase The instantaneous angular position which a sine wave occupies in its
cycle. The position is usually measured
in degrees as referenced to zero and
referred to as phase angle.
Polarity The positive and negative orientation of a source of power or signal.

6-3

Potentiometer (POT) A three terminal
device which consists of a fixed resistor
with terminations on each and a moveable
contact (wiper) that can travel between
the two terminations. Also called a variable resistor.
Power In a Direct Current circuit it is the
product of applied potential difference and
current. In an Alternating Current circuit it
is the product of the effective values of the
voltage and current with the cosine of the
phase angle between current and voltage.
The units of measurement are VA or watt.
Power Factor The ratio of true power to
apparent power in an alternating current,
or a ratio of resistance to impedance.
Quick Connect Terminals (Fast-on) A
solderless friction type termination used in
industrial controls to facilitate field wiring
of electrical control systems.
RC Resistor/capacitor network. See also
Snubber Network.
Rectifier (Diode) An electronic device
which allows current to flow in only one
direction. It is used to convert AC to DC.
Repeatability (Repeat Accuracy) The
percent variation of time within a group of
consecutive timing cycles, starting with
the second operation, when the timing
device is operated under constant conditions of operating voltage, ambient temperature, and ON/OFF times.
Reset Time The time a controller takes to
return to its initial parameters when input
power is removed.
Resistance The opposition to electric
current flow. All conductors offer some
resistance and the basic unit of resistance
is the ohm.
Resolution The degree of accuracy to
which a controller can be set to or the
degree of accuracy of an output function,
as in a digital readout of a specific output.
Rheostat A variable resistor having one
moveable contact (wiper), and one terminal fixed at one end of the resistance. A
potentiometer can be connected as rheostat by connecting the wiper to either one
of its other terminals.

Potential Difference The voltage differential between two points.

AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

6-4

GLOSSARY

RMS (Root Mean Square) Effective DC
value of sinewave voltage or current. The
effective value is .707 times the peak voltage or peak current measured.

Time Diagram A logic function drawing
used to relate the output operation of a
particular controller with regard to its input
parameters over a given period of time.

Series Circuit Loads connected end to
end across a voltage source.

Tolerance The permissible deviation from
a specified value of an electrical parameter. Normally stated as a percentage of a
nominal value.

Set Point The point at which a controller
will perform a function. The setpoint can
be either factory fixed or user adjustable
as in a temperature controller or a timer.
Setting Accuracy The degree of accuracy (resolution) to which a controller setpoint can be adjusted.
Shunt A low-resistance connection
between two points in an electric circuit
that forms another path for a large portion
of the current.
SPDT (Single Pole Double Throw)
A type of contact configuration which
consists of a Common contact, Normally
Open contact, and Normally Closed contact. In relay nomenclature, the states of
the contacts are given with the relay coil
unenergized.
Snubber Network Typically, a series connection of a resistor and capacitor applied
across an output device (especially solid
state) to minimize voltage spikes due to
line transients or load switching. It is used
to help prevent unwanted switching of
solid state devices and arcing of mechanical contacts.
Specified Delay Time The advertised
time, design print specified time, or set
time of the delay function.
Steady State The condition of a device
after power has been initially applied for
a certain period, or when its electrical
parameters are allowed to stabilize. This
condition is reflected in parameters such
as current flow, output voltage, and/or
temperature.
Storage Temperature The range of
ambient temperatures in which a controller is designed to be stored, in order to
assure operation within its specifications.
May be stated in Fahrenheit or Celsius.

Transient A momentary occurrence of a
particular phenomenon.
Transient Voltage Voltage spikes of
short duration which occur in electrical
circuits that exceed the normal designed
operating levels. Two main types of voltage transient wave forms are generally
used by the industry to define the typical transients found in the field. They are
defined in the IEEE C62.41 standard
IEEE Recommended Practice on Surge
Voltages in Low Voltage AC Power
Circuits. Transient surges considered in
this section do not exceed one-half period
of the applied AC line frequency. Also, the
magnitude of the crest voltage and current are designated as a peak open circuit
voltage of 6 kV and a peak short circuit
current of 3 kA. Of the two, the one which
simulates lightning transients is the combination 8/20 S current and 1.25/50 S
voltage wave form. The simulation of
transients generated by switching large
capacitive or inductive loads is represented by a 0.5 S –100 kHz ring wave.
Underwriter’s Laboratories Inc. (UL)
Testing agency for products sold in the
United States.
Volt The basic unit electromotive force or
potential difference.
Voltage The difference in electrical potential, or electromotive force between the
terminals of a source of electricity. It is
usually measure in volts.
Voltage Drop See On State Voltage.
Watt The basic unit of power.

Termination The point at which electrical
devices are connected to field wiring of
either inputs or outputs. Typical types of
termination are: Quick connect terminals,
screw terminals, flying leads, etc.
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com

ORDERING INFORMATION
How to Order
All of our standard industrial products are available through a national
distributor network. For the name of our nearest stocking distributor,
please call AMETEK NCC’s Customer Service Department at 630231-5900 or toll-free 800-323-2593.
If you do not find the product you are looking for in our catalog, or
you are unsure of what you need to fit your application, just call us for
technical assistance – we’ll be glad to help.

Our Warranty Policy
AMETEK NATIONAL CONTROLS CORPORATION warrants its products
for a period of one (1) year from date of receipt by user, but in no event
more that eighteen (18) months from date of manufacture, Against
defective material or workmanship, but not against damage caused by
accident, abuse, faulty installation, or improper application or operation. Probes are warranted for (90) ninety days.
During this period, AMETEK NCC will, at its option, repair or replace
defective products returned, transportation charges prepaid, to its factory.
AMETEK NCC shall not be liable for any indirect or consequential
damages. To the extent permitted by law, this is given in lieu of all other
warranties expressed or implied, and AMETEK NCC neither assumes
nor authorizes any person to assume for it any liability beyond stated
herein.

1725 Western Drive
West Chicago, Illinois 60185
Tel: 800-323-2593 • 630-231-5900
FAX: 630-231-1377

www.nationalcontrols.com
© 2005 by AMETEK, Inc. All rights reserved.
2.5M805OI (240012)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Page Count                      : 114
Page Mode                       : UseOutlines
Page Layout                     : TwoColumnRight
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:7f03efa8-0e25-42f5-9ab5-e3c310a59f42
Create Date                     : 2005:08:26 16:49:03Z
Metadata Date                   : 2005:09:13 15:14:43-04:00
Modify Date                     : 2005:09:13 15:14:43-04:00
Creator Tool                    : Adobe InDesign CS (3.0.1)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 7618 bytes, use -b option to extract)
Rendition Class                 : proof:pdf
Derived From Instance ID        : 41a8a8c6-1671-11da-bca5-f388cf852c03
Derived From Document ID        : adobe:docid:indd:b4383fc5-1666-11da-bca5-f388cf852c03
Document ID                     : adobe:docid:indd:41a8a8c7-1671-11da-bca5-f388cf852c03
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Reference Instance ID  : uuid:1e00f3f0-15a4-11da-b30c-b9af80dddde5, uuid:60244ff7-14c7-11da-9157-bc94bce53ef0, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:a2e208f7-cdfa-11d9-9326-c0e94f119bbe, uuid:b584f112-d204-11d9-806a-f8578b3a5d65, uuid:b584f112-d204-11d9-806a-f8578b3a5d65, uuid:93385834-ce18-11d9-9326-c0e94f119bbe, uuid:1b1e68dd-ce19-11d9-9326-c0e94f119bbe, uuid:1b1e68da-ce19-11d9-9326-c0e94f119bbe, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:50021010-c0c0-11d9-9b8f-da8fe3109f8f, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:6e0823fb-bb0d-11d9-9887-e50db6c1efde, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:14ba5179-b0d0-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:60267e57-b0cd-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:ebf34190-b10f-11d9-aec8-fdac430f158f, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:ebf3418d-b10f-11d9-aec8-fdac430f158f, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:efd76ba0-b0f9-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:6e92ce44-b1a3-11d9-8241-cbf9ba46708a, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:6e92ce47-b1a3-11d9-8241-cbf9ba46708a, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:6e92ce41-b1a3-11d9-8241-cbf9ba46708a, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:68565476-b365-11d9-826d-9f90ef42e85b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:68565479-b365-11d9-826d-9f90ef42e85b, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:d1f4ebe4-133b-11da-b402-a7535f7e0d52, uuid:54deb8c6-0a93-11da-a774-8734dd2927a0, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:98b36ef6-b654-11d9-adbe-980af8cee92a, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:8fcebd24-1342-11da-b402-a7535f7e0d52, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:fce6316b-b366-11d9-826d-9f90ef42e85b, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:fce6316e-b366-11d9-826d-9f90ef42e85b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:29800cb9-1339-11da-b402-a7535f7e0d52, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:664bd9d7-b367-11d9-826d-9f90ef42e85b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:6027c64b-b68e-11d9-8c35-a5803fc00968, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:ffc3dab4-b68e-11d9-8c35-a5803fc00968, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:5a20b367-0a97-11da-a774-8734dd2927a0, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:a323b7f2-0a9d-11da-a774-8734dd2927a0, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:3395f68c-b690-11d9-a960-d4f438df0a13, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:6027c64e-b68e-11d9-8c35-a5803fc00968, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:6027c651-b68e-11d9-8c35-a5803fc00968, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:ffc3dab1-b68e-11d9-8c35-a5803fc00968, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:98b36ef6-b654-11d9-adbe-980af8cee92a, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:efbb2ff1-b757-11d9-9970-e729c2256e33, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:efbb2ff4-b757-11d9-9970-e729c2256e33, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:efbb2ff7-b757-11d9-9970-e729c2256e33, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:523aa8af-b758-11d9-9970-e729c2256e33, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:523aa8b2-b758-11d9-9970-e729c2256e33, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:523aa8b6-b758-11d9-9970-e729c2256e33, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:50021010-c0c0-11d9-9b8f-da8fe3109f8f, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:d679bb02-bbd5-11d9-9b70-9f357dd59b4b, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:be24d9e9-bbd7-11d9-9b70-9f357dd59b4b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:2d213173-bbd8-11d9-9b70-9f357dd59b4b, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:2d213176-bbd8-11d9-9b70-9f357dd59b4b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:ed62e2b3-bbda-11d9-b4c4-c9824db96ec5, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:24a5b2ef-bbd9-11d9-9b70-9f357dd59b4b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:7296f32c-bbd9-11d9-9b70-9f357dd59b4b, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:ed62e2b8-bbda-11d9-b4c4-c9824db96ec5, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:7303b6e3-d20b-11d9-806a-f8578b3a5d65, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:595f12df-bbda-11d9-9b70-9f357dd59b4b, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:50021010-c0c0-11d9-9b8f-da8fe3109f8f, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:cb1272d6-bd8e-11d9-a241-85ba58911a28, uuid:cb1272d3-bd8e-11d9-a241-85ba58911a28, uuid:51c52647-c873-11d9-a60f-fa8d773bca51, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:3444d66a-bcc9-11d9-94df-ca651ecdef89, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:cb1272d3-bd8e-11d9-a241-85ba58911a28, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:51c52647-c873-11d9-a60f-fa8d773bca51, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:cb1272d6-bd8e-11d9-a241-85ba58911a28, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:cb1272d0-bd8e-11d9-a241-85ba58911a28, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:8970cb5e-bd8f-11d9-a241-85ba58911a28, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:50021010-c0c0-11d9-9b8f-da8fe3109f8f, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:65242fdf-c15c-11d9-8d78-9f954860d844, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:76c2c108-c314-11d9-9ced-91c277b1d706, uuid:76c2c10c-c314-11d9-9ced-91c277b1d706, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:1c32936b-c314-11d9-9ced-91c277b1d706, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:1c329373-c314-11d9-9ced-91c277b1d706, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:1c32936f-c314-11d9-9ced-91c277b1d706, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:673e51cc-f46c-11d9-9fc3-966f739731f1, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:3f4a505d-f480-11d9-87bc-9e9dad8a9942, uuid:3c646e18-fde9-11d9-af56-c734148e2689, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:65242fdf-c15c-11d9-8d78-9f954860d844, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:ab44eb2a-c225-11d9-8eb1-86edb08fd7e1, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:ab44eb2e-c225-11d9-8eb1-86edb08fd7e1, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:50021010-c0c0-11d9-9b8f-da8fe3109f8f, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:51c5264c-c873-11d9-a60f-fa8d773bca51, uuid:aae30f2b-c868-11d9-a60f-fa8d773bca51, uuid:3b1e8143-c867-11d9-a60f-fa8d773bca51, uuid:3b1e8147-c867-11d9-a60f-fa8d773bca51, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:aae30f2b-c868-11d9-a60f-fa8d773bca51, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:51c5264c-c873-11d9-a60f-fa8d773bca51, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:3b1e8147-c867-11d9-a60f-fa8d773bca51, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:3b1e8143-c867-11d9-a60f-fa8d773bca51, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:50021010-c0c0-11d9-9b8f-da8fe3109f8f, uuid:3184304d-b0ff-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:258dc9a1-b100-11d9-9174-ff52e62e7133, uuid:258dc9a5-b100-11d9-9174-ff52e62e7133, uuid:60244ffb-14c7-11da-9157-bc94bce53ef0, uuid:1e00f3f3-15a4-11da-b30c-b9af80dddde5
Manifest Reference Document ID  : adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:340f2751-d200-11d9-806a-f8578b3a5d65, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:c7c087b9-2be3-11d8-a626-c8da85b1796d, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:3fa15e45-c931-11d9-a8e0-c7196fd43083, adobe:docid:photoshop:8b4861ec-ce17-11d9-9326-c0e94f119bbe, adobe:docid:photoshop:8b4861ed-ce17-11d9-9326-c0e94f119bbe, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:510ec244-bb0d-11d9-9887-e50db6c1efde, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:60267e59-b0cd-11d9-9174-ff52e62e7133, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:60267e51-b0cd-11d9-9174-ff52e62e7133, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ebf34189-b10f-11d9-aec8-fdac430f158f, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:2acd85a6-b0e5-11d9-9174-ff52e62e7133, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:7fa8ab47-b0eb-11d9-9174-ff52e62e7133, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:7fed9725-b1a0-11d9-8241-cbf9ba46708a, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:7fed9727-b1a0-11d9-8241-cbf9ba46708a, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:7fed9729-b1a0-11d9-8241-cbf9ba46708a, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:41ad9322-b365-11d9-826d-9f90ef42e85b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6856546f-b365-11d9-826d-9f90ef42e85b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:d1f4ebde-133b-11da-b402-a7535f7e0d52, adobe:docid:photoshop:309b1ecd-b366-11d9-826d-9f90ef42e85b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:825066b2-b654-11d9-adbe-980af8cee92a, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:30d35103-0a95-11da-a774-8734dd2927a0, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6a816a9b-b366-11d9-826d-9f90ef42e85b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6a816a9c-b366-11d9-826d-9f90ef42e85b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:a4aa0250-0a95-11da-a774-8734dd2927a0, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6a816a9e-b366-11d9-826d-9f90ef42e85b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6027c648-b68e-11d9-8c35-a5803fc00968, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:4a74a841-b68e-11d9-8c35-a5803fc00968, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:a4aa0255-0a95-11da-a774-8734dd2927a0, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:5a20b36a-0a97-11da-a774-8734dd2927a0, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:3395f689-b690-11d9-a960-d4f438df0a13, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:4a74a847-b68e-11d9-8c35-a5803fc00968, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:4a74a845-b68e-11d9-8c35-a5803fc00968, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:4a74a843-b68e-11d9-8c35-a5803fc00968, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:825066b2-b654-11d9-adbe-980af8cee92a, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:33893a9e-b757-11d9-9970-e729c2256e33, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ad1359e3-b757-11d9-9970-e729c2256e33, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ad1359e5-b757-11d9-9970-e729c2256e33, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ad1359e7-b757-11d9-9970-e729c2256e33, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ad1359e9-b757-11d9-9970-e729c2256e33, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ad1359ed-b757-11d9-9970-e729c2256e33, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:5bddecb8-bbd5-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:d679bb04-bbd5-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:d679bb06-bbd5-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:d679bb0a-bbd5-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:e545226f-bbda-11d9-b4c4-c9824db96ec5, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:2d21317a-bbd8-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:24a5b2f3-bbd9-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ed62e2b5-bbda-11d9-b4c4-c9824db96ec5, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:7303b6e0-d20b-11d9-806a-f8578b3a5d65, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:24a5b2f1-bbd9-11d9-9b70-9f357dd59b4b, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:6b114d6b-bd8e-11d9-a241-85ba58911a28, adobe:docid:photoshop:6b114d6c-bd8e-11d9-a241-85ba58911a28, adobe:docid:photoshop:51c52644-c873-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:f5b211e0-bcc8-11d9-94df-ca651ecdef89, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6b114d6c-bd8e-11d9-a241-85ba58911a28, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:51c52644-c873-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6b114d6b-bd8e-11d9-a241-85ba58911a28, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:cb1272cd-bd8e-11d9-a241-85ba58911a28, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:6b114d6a-bd8e-11d9-a241-85ba58911a28, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:9379fcef-c15a-11d9-8d78-9f954860d844, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:76c2c105-c314-11d9-9ced-91c277b1d706, adobe:docid:photoshop:76c2c109-c314-11d9-9ced-91c277b1d706, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:9cf2b31a-c313-11d9-9ced-91c277b1d706, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:1c329370-c314-11d9-9ced-91c277b1d706, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:1c32936c-c314-11d9-9ced-91c277b1d706, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:cd0ee884-f46b-11d9-9fc3-966f739731f1, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:3fa15e45-c931-11d9-a8e0-c7196fd43083, adobe:docid:photoshop:41dfcf66-fdd8-11d9-af56-c734148e2689, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:9379fcef-c15a-11d9-8d78-9f954860d844, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:d55ee97b-c21c-11d9-8eb1-86edb08fd7e1, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ab44eb2b-c225-11d9-8eb1-86edb08fd7e1, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:51c52649-c873-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:aae30f28-c868-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:053e1312-c867-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:3b1e8144-c867-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:aae30f28-c868-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:51c52649-c873-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:3b1e8144-c867-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:053e1312-c867-11d9-a60f-fa8d773bca51, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:074497e7-6982-11d9-a333-f5c618cf942e, adobe:docid:photoshop:60244ff8-14c7-11da-9157-bc94bce53ef0, adobe:docid:photoshop:ce632b03-9235-11d9-adea-d41100f2fb93
Format                          : application/pdf
Title                           : 240012.indd
Trapped                         : False
Creator                         : Adobe InDesign CS (3.0.1)
Producer                        : Adobe PDF Library 6.0
EXIF Metadata provided by EXIF.tools

Navigation menu