Product Detail Manual
35906-Brochure 35906-Brochure 35906-Brochure 745976 Batch5 unilog cesco-content
2014-07-05
: Pdf 35906-Attachment 35906-Attachment 745976 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 2
DOWNLIGHTING 603
Catalog
Number
Notes
Type
603
Series Finish
603 AZ Clear specular
A Clear diuse
ORDERING INFORMATION For shortest lead times, congure product using standard options (shown in bold). Example: 603 AZ
All dimensions are inches (centimeters).
FEATURES & SPECIFICATIONS
INTENDED USE
For use with rough-in LP6 and housings LC6, LI6, L7X, L7XR, L7XF, L7XFR and LI6F.
CONSTRUCTION
Aluminum one piece reector.
Premium specular and diuse nishes in clear.
White integral ange as standard.
INSTALLATION
Socket to trim interface.
Retaining clips riveted to top of reector hold trim inside housing.
Rough-ins with clips retain trims.
LISTING
U.L. Listed to U.S. and Canadian safety standards.
Damp location listed.
6" Finishing Trim
6O3
PREMIUM SPECULAR OPEN
Narrow Flange
Specications
Height: 7-1/4 (18.4)
Lamp opening: 6-5/8 (16.8)
Diameter: 6-7/8 (17.5)
Trim heights when used with
Non IC Rough-Ins.
6-5/8
(16.8)
6-7/8
(17.5)
7-1/4
(18.4)
Housing Compatibility: Housing and trim ordered separately.
Maximum
Application Source wattage Housing
IC Incandescent 100 PAR38 LI6
65 BR40 LI6
75 A19 LI6
Fluorescent 13DTT L7XF, L7XFR
18DTT L7XF, L7XFR, LI6F
18TRT LI6F
26TRT L7XF, L7XFR, LI6F
Non-IC Incandescent 150 PAR38 LP6, LC6, L7X, L7XR
120 BR40 LP6, LC6, L7X, L7XR
100 A19 LC6, L7X, L7XR
150 A19 LP6
Fluorescent 18DTT L7XF, L7XFR
26TRT L7XF, L7XFR
603
DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800.315.4963 Fax: 770-981-8191 www.lithonia.com ©2000 Acuity Brands, Inc. All rights reserved. Rev. 08/31/10
6O3 6" Premium Specular Open Full Reector Trim
Distribution curve Distribution data Output data Coecient of utilization Single luminaire data 30" above oor
6O3A, 100W A19 lamp, 1.3 s/mh, 1750 rated lumens, test no. 2194040906
0°
45°
90°
90°
0°
45°
6O3A, 13W F13DTT/27K lamp, 1.0 s/mh, 900 rated lumens, test no. 2194061705
rf 20%
rc 80% 70% 50%
rw 50% 30% 50% 30% 50% 30%
1 78 77 77 75 74 73
2 73 70 72 69 69 68
3 68 65 67 64 65 63
4 64 60 63 59 61 58
5 59 55 58 54 57 54
6 55 51 54 50 53 50
7 51 47 50 46 50 46
8 47 43 47 43 46 42
9 44 39 43 39 43 39
10 41 36 40 36 40 36
Zone Lumens %lamp
0°-30° 303 33.8
0°-40° 466 51.9
0°-60° 608 67.6
0°-90° 609 67.7
90°-180° 0 0.0
0°-180° 609 67.7*
* Eciency
50% 10%
Beam angle 52.2° Beam angle 91.2°
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 15.5 5.4' 7.7 11.2' 1.5
10' 8.3 7.3' 4.2 15.3' 0.8
12' 5.2 9.3' 2.6 19.4' 0.5
14' 3.5 11.3' 1.8 23.5' 0.4
16' 2.6 13.2' 1.3 27.6' 0.3
Zone Lumens %lamp
0°-30° 656 37.5
0°-40° 995 56.9
0°-60° 1234 70.5
0°-90° 1236 70.7
90°-180° 0 0.0
0°-180° 1236 70.7*
* Eciency
50% 10%
Beam angle 64.3° Beam angle 90.1°
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 25.5 6.9' 12.8 11.0' 2.6
10' 13.7 9.4' 6.9 15.0' 1.4
12' 8.6 12.0' 4.3 19.0' 0.9
14' 5.8 14.5' 2.9 23.1' 0.6
16' 4.2 17.0' 2.1 27.1' 0.4
rf 20%
rc 80% 70% 50%
rw 50% 30% 50% 30% 50%
30%
1 75 73 74 72 71 70
2 70 67 69 66 66 65
3 65 61 64 61 62 60
4 60 57 60 56 58 55
5 56 52 55 52 54 51
6 52 48 51 47 50 47
7 48 44 48 44 47 43
8 44 40 44 40 43 39
9 41 37 41 37 40 39
10 38 34 38 34 37 33
From 0° cp. Lumens
0° 467
5° 479 45
15° 378 109
25° 326 150
35° 262 163
45° 144 110
55° 30 31
65° 0 1
75° 0 0
85° 0 0
90° 0
From 0° cp. Lumens
0° 771
5° 798 76
15° 826 232
25° 759 348
35° 558 340
45° 220 181
55° 57 57
65° 0 2
75° 0 0
85° 0 0
90° 0
170
340
510
680
850
100
200
300
400
500
To calculate light levels for other lamps, multiply the footcandle levels by the ratio of
desired-lamp lumens to displayed-lamp lumens.
Example: fc level at nadir for 100W A19 is 19.
With a 75W A19, fc level is 19 x (1,210/1,750) or 13 fc.
Incandescent Compact Fluorescent
Lamp Lumens Lamp Lumens
150W A21 2,850 26W DTT 1,800
100W A19 1,750 18W DTT 1,250
75W A19 1,210 13W DTT 860
60W A19 870
40W A19 460
Consult chart on page LAMP for appropriate R or PAR lamp data.
Conversion Factor
Use multiplier to determine candlepower, lumens and
footcandles of other nishes.
Gold = .9.