378231 Catalog

2014-10-17

: Pdf 378231-Catalog 378231-Catalog 745975 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 52

Download378231-Catalog
Open PDF In BrowserView PDF
Indoor HID
Lithonia Lighting offers a wide selection of indoor HID
products to address high-mount and low-mount
lighting applications.

Lithonia industrial lighting withstands vibration, dirt,
heat, moisture and corrosiveness while providing
proper levels of efficient illumination. Lithonia
commercial lighting provides a bright, cheerful and
relaxed atmosphere that enhances customer and
worker comfort. Lithonia recreational lighting delivers
glare-free illumination so that playing surfaces and the
surrounding environment are adequately illuminated

LITHONIA INDOOR HID

for spectator and player safety.

346

www.lithonia.com

PSG9

CONTENTS

353

358

362

372

381

PSG9

348

Ballast Housings

350

High Bay
Durabay® Glass
Acrylume® Acrylic
Hi-Tek® Aluminum

353
358
362

Low Bay
Acrylume® Acrylic
Hi-Tek® Aluminum
Food Processing
Refractor & Low Wattage

360
370
374
376

Recessed HID

378

Dock Lights

380

KiloWatch
KiloWatch® HID Control System

381

Technical Info
Ballast Selection Guide
Protected Sockets

384
385

Options and Accessories
Miscellaneous
Cord Mounting
Power Hooks
Wireguards

386
388
390
392

356

360

361

363

370

374

376

379

380

390

393

www.lithonia.com

LITHONIA INDOOR HID

377

354

Optical Selection Guide

347

OPTICAL SELECTION GUIDE

Low Bays/High Bays
Selecting the proper optical for your application is essential to obtain desirable results and a high quality lighting installation. Making the proper choice can
become complicated with the many different aspects of a space to consider and the wide selection of optics from which to choose. Determining the mounting height for an application is the first step to narrowing the selection.
HID lighting fixtures are grouped in two general categories of low bays and high bays. Low bays are for areas with mounting heights typically under 20 feet.
High bays are designed for spaces with mounting heights of approximately 18 feet and higher.

Low Bays

Low bays are designed with distributions to
spread the light out in a space and prevent hot
spots of light below the luminaire. The bottom
prismatic lens bends the light to create wide distributions that improve uniformity and increase
vertical illumination at lower mounting heights.
Low bays perform best at mounting heights less
than 20 feet and are available in various wattages up to 450 watts. The prisms reduce glare and

brightness by obscuring the lamp from view and
spread out the lamp image across the lens, improving visual comfort within a space. All lenses
are gasketed and supported by a door ring held
in place with stainless spring steel latches that
ensure a tight seal to minimize dirt entry. Optional charcoal filtering provides added protection against contaminant entry by controlling
and cleaning airflow into the luminaire.

High Bays

High bays have distributions for directing light
downward to maximize horizontal light levels
on an area or task. Mounted at heights of 18 feet
to more than 40 feet, they are available with narrower distributions and wattages up to 1000
watts. Glare and brightness are not as critical as
for low bays since the luminaires are mounted
high above and viewed from greater distances
away. These reflectors typically are open to maximize output efficiency and minimize dirt accumulation. Open-top, open-bottom reflectors stay
cleaner because the heat from the lamp creates
a convective airflow that continually moves dirt and dust
away from the reflector.

Enclosed high bays have a flat clear lens to minimize degradation of the anodized finish in harsh
environments or contain the lamp if breakage
occurs from impact to the luminaire or arc tube
rupture. A flat lens typically will reduce luminaire efficiency by 5-10% compared to the same
reflector open. All lenses are gasketed and supported by a door ring held in place with stainless
spring steel latches that ensure a tight seal to
minimize dirt entry. Optional charcoal filtering
provides added protection against contaminant
entry by controlling and cleaning airflow into
the luminaire.

air flow
Material Choice
Low bays and high bays primarily are available in aluminum, acrylic and glass. Each material differs in performance, cost and durability making them suitable for a variety of applications for different reasons.

LITHONIA INDOOR HID

Hii-TTek
ek® Aluminum

348

• Maximized horizontal light levels
• High ambient temperature
• Impact tolerant
• Oily and corrosive environments (high bays)

Aluminum is an economical and easily shaped
material used to produce efficient reflectors that
can withstand impact and high ambient temperatures. Different finishes are applied for protection and photometric performance. An anodized
finish protects against corrosion, oily environments and increases control of the reflected
light to produce distinct distributions with efficient photometric performance. A highly reflective white polyester powder coat paint finish
provides excellent protection against many corrosive compounds and creates a widespread distribution for low bays that helps reduce glare
from the lamp. Hi-Tek reflector designs are available in both low bays and high bays that maximize downward efficiency with very little or no
uplight component.
Hi-Tek low bay opticals combine aluminum reflectors with prismatic acrylic refractor lenses.

Together they produce wide distributions that
maximize downward efficiency, minimize glare
and enhance vertical illumination. These are ideal for applications with darker ceilings or where
uplight is not desired or beneficial in applications such as retail, sports facilities, manufacturing, heavy industrial and food processing. See
Acrylume® acrylic section on next page for limitations of acrylic.
Hi-Tek open high bay reflectors have narrower
distributions to maximize downward efficiency
and horizontal light levels from high mounting
heights. Applications for these reflectors include
warehouses, manufacturing facilities, heavy industrial and other areas with high mounting
heights or where uplight is not desired or beneficial. Enclosed versions are available with a gasketed flat tempered glass lens and door.

• Long service life
www.lithonia.com

PSG9

Low Bays/High Bays

Acrylume® low bay optics combine acrylic reflectors with prismatic acrylic refractor lenses. This
combination is superior for glare and brightness
control, vertical illumination and overall uniformity. The high quality of light delivered by these
optics make them well suited for retail, institutional, sports facilities, food processing and light
manufacturing applications at mounting heights
less than 20 feet. A flat clear bottom lens is available in tempered glass or acrylic that produce
narrower distributions suitable for mounting
heights above 18 feet.

Acrylume® open high bay reflectors produce distributions for mounting heights above 18 feet.
The prismatic reflector has an uplight component of 15 to 20% that illuminates surfaces
above the luminaire. This eliminates shadows
and scalloping along walls and at tops of warehouse aisleways. Applications include retail,
light manufacturing, warehousing and institutional buildings.

Acrylume
Acrylume® Acrylic

Acrylume® acrylic optics are UV stabilized to prevent yellowing for ten years when operating at
or below the luminaire’s ambient temperature
rating. Acrylic is susceptible to degradation from
exposure to certain chemical compounds and
oils. Compatibility must be verified for applications with air borne contaminants by referencing the acrylic environmental compatibility
chart on page 735. Acrylic reflectors and refractors need to be replaced once they become visibly yellow or show signs of hazing or cracking
from degradation by contaminants.

OPTICAL SELECTION GUIDE

Prismatic acrylic reflector and refractor designs
are a popular choice for many applications. Acrylume® opticals boast higher luminaire efficiencies than aluminum reflectors through an added
uplight component that smoothly illuminates
the ceiling surface. A brighter ceiling reduces
the background contrast so the luminaires do
not appear to be as bright. The added uplight
also contributes to better vertical illumination,
greater uniformity and a more natural daylight
feeling within a space.

• High luminaire efficiency
• Uplight and vertical illumination
• Brightness and glare control
• High uniformity

Borosilicate glass is a material with many attributes that make it an ideal solution for HID
lighting. DuraBay prismatic glass can withstand
operation in 65° C ambient temperatures without ever discoloring, turning yellow or deforming. Glass does not have a static charge that attracts dirt, so it remains cleaner longer with
higher maintained luminaire efficiency than aluminum or acrylic. It also endures corrosive and
oily environments better than any other material or finish. Original optical performance is easily restored with proper cleaning.
DuraBay high bay distributions have an uplight
component of 20 to 25% that evenly illuminates
the ceiling above. This reduces background contrast and perceived brightness of the luminaire
creating a more visually comfortable environ-

ment. Uplight also contributes to better vertical
illumination, greater uniformity and a more natural daylight feeling within a space. The prismatic design minimizes reflector side wall brightness by breaking up the reflected lamp image increasing visual comfort. Enclosed versions are
available with a gasketed flat tempered glass
lens door and optional charcoal filter. Applications include retail, manufacturing, warehousing, sports facilities and institutional buildings.

DuraBay
DuraBay® Borosilicate Glass

• Brightness & glare control
• Uplight and vertical illumination
• Highest maintained efficiency
• Oily and corrosive environments
• High ambient temperatures
• Longest service life

PSG9

www.lithonia.com

LITHONIA INDOOR HID

DuraBay open and enclosed glass high bays with
aluminum shroud maximize downward efficiency and horizontal light levels similar to aluminum high bays, but with the benefits and performance of glass. These reflectors deliver highest
maintained efficiency, superior durability in the
toughest environments, and excellent glare and
brightness control. Applications include heavy
industrial, manufacturing, warehousing and
sports facilities.

349

BALLAST HOUSINGS

Die-Cast Aluminum Housings, Interchangeable Opticals
TH High Bay
TH Ballast Housing

TH Large Ballast Housing

Modular ballast housing for high bay
o p t i c a l s . Pre-attached adjustable legs accept a wide selection of anodized aluminum
and prismatic acrylic high bay reflectors. A variety of distribution patterns at higher mounting heights can be achieved. These systems

Housing
TH
TH
TH
TH
TH
TH

Reflector
A14
A15
A16
A17, A221
PA16,PA22,
PA22E, PA22L
PA22N,PA22SP,
PA251

provide minimum brightness and glare, and superior energy efficiency.
Large ballast housing utilized for optional high
ambient temperature rating and for 4501000W ballasts.

Primary function
Vertical illumination; aisleways.
Horizontal illumination.
High efficiencies; glare control.
Optimum lamp shielding; glare control.
High efficiencies; vertical & horizontal
illumination; uplight; glare control.
High efficiencies uplight; glare control; more
narrow distributions for higher mounting heights.

Typical
mounting height
18’-35’
18’-25’
18’-35’
18’-40’+
18’-35’

Page
368
366
364
362
358

20’-40’+

358

TX Low Bay
TX Ballast Housing

Modular ballast housing for enclosed low bay
opticals. Accepts various heavy-duty aluminum
and prismatic acrylic low bay optical assemblies.
Designed to provide uniform, glare-free energyefficient lighting. Opticals are equipped with a
heat-resistant, dust-inhibiting gasket at the point

Housing
TX
TX
TX

Optical
A121, A125
A162, A165
PA22C

TX

PA25D

TX
TX

PA22GLE,
PA25ALE
A20

TX

A26

TX
TX

LITHONIA INDOOR HID

TX Large Ballast Housing

350

of attachment and a fully gasketed lens door
assembly.
Large ballast housing utilized for optional high
ambient temperature ratings and for 450W
ballasts.

Primary function
Lower wattage; vertical and horizontal illumination.
Vertical and horizontal illumination.
High efficiencies; vertical illumination with uplight;
glare control.
High efficiencies; vertical and horizontal illumination;
glare control.

Typical
mounting height
8’-16’
14’-20’

Page
375
375

14’-20’

361

14’-20’

361

High efficiencies; vertical and horizontal illumination
(higher mounting).
Lower wattage; premium glare control.
Vertical and horizontal illumination; premium glare
control.

14’-25’

360

10’-16’

370

14’-20’

370

A30

High efficiencies; vertical and horizontal illumination;
glare control; low brightness.

14’-20’

371

A23

High efficiencies; glare control; vertical and horizontal
illumination.

14’-20’

372

NOTES:
1 Suitable for 875W and 1000W using large ballast housing.

www.lithonia.com

PSG9

Die-Cast Aluminum Housing, Optic Specific
Provides reliable, simple installation of open
glass and shrouded glass reflectors with heavygauge mounting brackets and sliding safety
latches. Heavy-duty, die-cast splice box allows
flexibility for surface, through-wire or pendant
Housing
TPG
TPG
TPG
TPG

Reflector
PG16
PG16A
PG211
PG21A1

Primary function
Optimum efficiencies; balance of uplight and downward distribution.
Provides downward distributions and softens lamp image.
Optimum efficiencies; balance of uplight and downward distribution.
Provides downward distributions and softens lamp image.

Accepts enclosed and gasketed glass optical assemblies in both the standard and shrouded
versions. Opticals are equipped with a heat-resistant, dust-inhibiting gasket at the point of attachment and a fully gasketed lens ring assembly. Heavy-duty, die-cast splice box allows flexiHousing

Reflector

TPGE

PG16GLE

TPGE

PG16AGLE

TPGE

PG21GLE1

TPGE

PG21AGLE1

mounting. Distributions are designated in the
catalog number and factory-preset. Large ballast housing utilized for optional high ambient
temperature rating and for 450-1000W ballasts.

Mounting height
16’-35’
16’-35’
20’-40’+
20’-40’+

TPG Large Ballast Housing

Page
354
355
354
355

bility for surface, through-wire or pendant
mounting. Distributions are designated in the
catalog number and factory-preset. Large ballast housing utilized for optional high ambient
temperature rating and 450-1000W ballasts.

Primary function
Optimum efficiencies and a balance of uplight and downward
distributions while providing total enclosure of the lamp.
Provides downward distributions and softens lamp image while
providing total enclosure of the lamp.
Optimum efficiencies and a balance of uplight and downward
distributions while providing total enclosure of the lamp.
Provides downward distributions and softens lamp image while
providing total enclosure of the lamp.

TPG Ballast Housing

Mounting height

Page

16’-35’

356

16’-35’

357

20’-40’+

356

20’-40’+

357

BALLAST HOUSINGS

TPG Open Glass High Bay

TPGE Enclosed Glass High Bay
TPGE Ballast Housing
TPGE Large Ballast Housing

TE Enclosed Aluminum High Bay
Designed for E17 and E22 totally enclosed aluminum optical assemblies. Opticals are
equipped with a heat-resistant, dust-inhibiting
gasket at the point of attachment and a fullygasketed lens ring assembly. Distributions are

Housing
TE
TE

Reflector
E17
E221

designated in the catalog number and factorypreset. Large ballast housing utilized for optional high ambient temperature rating and 4501000W ballasts.

Primary function
Totally enclosed optics, optimum lamp shielding and glare control.
Totally enclosed optics, optimum lamp shielding and glare control.

Mounting height
20’-40’+
25’-40’+

TE Ballast Housing
TE Large Ballast Housing

Page
363
363

TXF Low Bay

Housing

Optical

TXF

A30F

TXF

PA25ALEF

posed threads and NSF certification. These systems provide glare-free, energy-efficient lighting. Large ballast housing is standard for optimal
operating temperature.

Primary function
High efficiencies; vertical & horizontal illumination; glare control; low
brightness. Hose-down tested to 1200psi, IP65 rated. Wet location listed.
High efficiencies; vertical and horizontal illumination; glare control.
IP65 rated. Wet location listed.

Mounting height

Page

14’-20’

374

14’-25’

374

NOTES:
1 Suitable for 750W, 875W and 1000W using large ballast housing.

PSG9

www.lithonia.com

TXF Ballast Housing

LITHONIA INDOOR HID

Designed for food processing areas and wet location applications. These assemblies feature
fully gasketed construction, special FDA/USDAcompliant materials and finish, stainless steel
and corrosion-resistant hardware with no ex-

351

BALLAST HOUSINGS

Steel Housings, Interchangeable Opticals
SH High Bay
SH Ballast Housing

Modular ballast housing for high bay opticals.
Pre-attached adjustable legs accept a wide
selection of anodized aluminum and prismatic
acrylic high bay reflectors. A variety of
distribution patterns at higher mounting
heights can be achieved. These systems provide

Housing
SH
SH
SH
SH
SH

Reflector
A14
A15
A16 A16GL
PA22
PA22N, PA22SP

minimum brightness and superior energy
efficiency. Ventilated design optimizes thermal
performance of enclosed electronic ballast
housing. Optional heat shield provided for high
ambient temperature rating.

Primary function
Vertical illumination aisleways.
Horizontal illumination.
High efficiencies; glare control.
High efficiencies; vertical & horizontal illumination; uplight; glare control.
High efficiencies; vertical & horizontal illumination; uplight; glare control;
narrower distribution for higher mounting heights.

Mounting height
18’-35’
18’-25’
18’-35’
18’-35’

Page
369
367
365
359

20’-40’+

359

SX Low Bay

SX Ballast Housing

Modular ballast housing for enclosed low bay
opticals. Accepts heavy-duty aluminum optical
assembly. Designed to provide uniform, glarefree energy-efficient lighting. Optical are
equipped with a heat-resistant, dust-inhibitive

gasket at the point of attachment and a fully
gasketed lens door assembly. Ventilated design
optimizes thermal performance of enclosed
electonic ballast housing. Optional heat shield
provided for high ambient temperature rating.

Housing

Optical

Primary function

Mounting height

Page

SX

A23

High efficiencies; glare control; vertical and horizontal illumination.

14’-20’

373

LITHONIA INDOOR HID

SPG High Bay

352

SPG Ballast Housing

Modular ballast housing for open glass high
bay opticals. Provides reliable, simple installation of open glass and shrouded glass reflectors
with heavy-gauge mounting brackets and sliding
safety latches. Distributions are designated in the

Housing
SPG

Reflector
PG15

catalog number and factory-preset. Vented design optimizes thermal performance of enclosed
electronic ballast housing. Optional heat shield
provided for high ambient temperature rating.

Primary function
Optimum efficiencies; balance of uplight and downward distribution.

www.lithonia.com

Mounting height
16’-35’

Page
353

PSG9

Open Glass Optical
For high mounting heights that require high efficiencies, horizontal and vertical illumination
and premium contrast control. Ideal for retail
and warehouse applications. Steel ballast housing (SPG) should be used in areas with minimal
airborne contaminants.
Features
Housing – Steel housing with white polyester
powder coat finish. All electrical components
are positioned to assure unit will hang
straight. Housing is ventilated for optimal
thermal performance.
Ballast – Electronic ballast is 100% factory tested. Ballast will operate pulse start metal halide
lamps only from 200-277V.
Optics – High-efficiency, high-performance,
heat-resistant borosilicate glass reflector is
mounted with a heavy-guage rigid wire form fitted to top of reflector. Opticals have a self-clean-

ing, ventilated design that carries optical contaminants out through top of reflector for maximum performance. Prismatic glass controls
glare, reduces reflector-side wall brightness, and
adds uplight component for greater visual comfort and improved uniformity.

SPG
DuraBay™

HIGH BA
Y
BAY

Intended Use

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.
Installation – One-piece galvanized hook and
spring steel latch with cord and plug (SC3P) is
standard. Pendant splice box (PSB) with top entry for ¾” conduit also available with other
mounting options.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 40°C (High Ambient HA
option for 55°C).

PG15

Example: SPG 400M PG15 M 277 GEB SC3P

Ordering Information

Series

Wattage

Optical

SPG

Metal halide protected1
320MP
350MP
400MP
Metal halide
400M

PG15

Distribution (select one)

Voltage

N
C
M
S
W

208
240
277
TVOLT2

Narrow
Concentrating
Medium
Spread
Widespread

Ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Options/Accessories
See pages 386-397. HID lamps are available with luminaires. Consult factory.

Pulse start metal halide
GEB Electronic ballast
See pages 384-385 for details.

Lamp/fixture data
Standard
Weight
Spacing criteria
Wattage ballast
lbs. kgs.
N C M S W
Metal halide (mog/clear)
400
GEB
21 9.5
0.7 1.0 1.3 1.7 2.1

NOTES:
1 See page 385 for details on protected sockets.
2 Tri-volt electronic ballast capable of operating on any line voltage between 200V
and 277V at 50 or 60 Hz. Pendant splice box (PSB) mounting required.

PSG9

www.lithonia.com, keyword: SPG-PG15

SPG PG15
Overall height: 20-7/16 (51.95)
Reflector height: 10-9/16 (26.85)
Diameter: 15-9/16 (39.56)

LITHONIA INDOOR HID

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

353

HIGH BA
Y
BAY

Premium Open Glass Optical

TPG

Intended Use
For high mounting heights that require high efficiencies, horizontal and vertical illumination,
and premium contrast control. Optimum performance for high ambient temperatures and dirty
environments. Ideal for heavy manufacturing areas, retail and warehouse aisles.

DuraBay™

Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – High-efficiency, high-performance,
heat-resistant borosilicate glass reflector
mounted within heavy-gauge rigid wire form
rings and rods fitted to top of reflector and bottom of reflector. Yields high vertical footcandles

PG21

PG16

Wattage

TPG
150S
200S
250S
400S
400S
1000S

LITHONIA INDOOR HID

175MP
200MP
250MP
320MP
350MP
400MP
450MP
200MP
350MP
400MP
450MP
875MP
1000MP

354

400M
400M
1000M

Optical

Distribution (select one)

High pressure sodium
PG16
N
C
M S W
PG16
–
C
M S W
PG16
–
C
M S W
PG16
–
C
M S W
PG21
– C21 – – –
PG21
– – M21 – –
Metal halide protected1
PG16
N
C
M S W
PG16
N
C
M S W
PG16
N
C
M S W
PG16
N
C
M S W
PG16
N
C
M S W
PG16
N
C
M S W
PG16
N
C
M S W
PG21
N21 –
– – –
PG21
N21 –
– – –
PG21
N21 –
– – –
PG21
N21 –
– – –
PG21
– C21 – – –
PG21
– C21 – – –
Metal halide
PG16
N
C
M S W
PG21
N21 –
– – –
PG21
– C21 – – –

Voltage

Ballast

120
208 2,3
2402,3,4
277
347
480 2,3
TB5
TBV6

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

N
C
M
S
W

=
=
=
=
=

Installation – Cast-aluminum pendant splice box
threaded for ¾” conduit (standard). Other
mounting options available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient
HA option for 65°C). 875W and 1000W pulsestart -30°C to 40°C.

Options/Accessories
See pages 386-397. HID lamps are available
with luminaires. Consult factory.

Lamp/fixture data
Standard
Weight
Wattage ballast
lbs. kgs.
N
High pressure sodium (mog/clear)
150 (PG16) CWA
32 15
0.7
200 (PG16) CWA
35 16
–
250 (PG16) CWA
35 16
–
400 (PG16) CWA
38 17
–
400 (PG21) CWA
55 25
–
1000 (PG21) CWA
55 25
–
Metal halide (mog/clear)
400 (PG 16) CWA
36 16
0.7
400 (PG21) CWA
55 25
0.7
1000 (PG21) CWA
55 25
–

Spacing criteria
C M S W
1.0
0.8
0.8
0.8
1.1
–

1.3
1.2
1.2
1.2
–
1.5

1.7
1.6
1.6
1.7
–
–

2.0
1.9
1.9
2.0
–
–

1.0 1.3 1.7 2.0
– – – –
0.9 – – –

Narrow
Concentrating
Medium
Spread
Widespread

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

TPG PG16
Overall height: 26 (66.0)
Reflector height: 15-1/2 (39.4)
Diameter: 17-1/2 (44.5)

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. 5KV pulse rated
for 1000S. Protected version with pink exclusionary socket.

Example: TPG 400MP PG16 M TB SCWA QRS

Ordering Information

Series

with low brightness and excellent contrast control. Self-cleaning, ventilated design carries optical contaminants out through top of reflector.

TPG PG21
Overall height: 28 (71.1)
Reflector height: 19-1/2 (49.5)
Diameter: 22 (55.9)

www.lithonia.com, keyword: TPG

NOTES:
1 See page 385 for details on protected sockets.
2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
3 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
4 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
6 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).

PSG9

Premium Open Shrouded Glass Optical
For high mounting heights that require high efficiencies, horizontal illumination and premium
contrast control. Optimum performance for high
ambient temperature and dirty environments.
Ideal for heavy manufacturing areas, retail and
warehouse aisles.
Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components are horizontally opposed and
heat-sinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – High-efficiency, high-performance,
heat-resistant borosilicate glass reflector with
aluminum shroud to protect glass prisms from

oily dirt accumulation, emphasizing downward
efficiency. Self-cleaning, ventilated design carries optical contaminants out through top of reflector.

TPG
DuraBay™

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. 5KV pulse rated
for 1000S. Protected version with pink exclusionary socket.

HIGH BA
Y
BAY

Intended Use

Installation – Cast-aluminum pendant splice box
threaded for ¾” conduit (standard). Other
mounting options available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 55°C). 875W and 1000W pulse-start 30°C to 40°C.

PG16A

PG21A

Example: TPG 400MP PG16A M TB HC3P

Ordering Information
Series

Wattage

TPG
150S
200S
250S
400S
400S
1000S
175MP
200MP
250MP
320MP
350MP
400MP
450MP
350MP
400MP
450MP
875MP
1000MP

Distribution (select one)

High pressure sodium
PG16A
N
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG21A
– C21
– –
PG21A
– –
M21 –
Metal halide protected1
PG16A
–
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG16A
–
C
M S
PG21A
N21 –
– –
PG21A
N21 –
– –
PG21A
N21 –
– –
PG21A
– C21
– –
PG21A
– C21
– –
Metal halide
PG16A
N
C
M S
PG21A
N21 –
– –
PG21A
– C21
– –

NOTES:
1 See page 385 for details on protected sockets.
2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
3 Requires CWI or MRB option in Canada for high pressure sodium. Available
for 70-400W only.
4 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
6 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium(CWA only).

PSG9

W
W
W
W
–

Voltage

Ballast

Options/Accessories

120
208 2,3
2402,3,4
277
347
480 2,3
TB5
TBV6

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are available
with luminaires. Consult factory.

W
W
W
W
W
W
W
–
–
–
–
–
W
–
–

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

N
C
M
S
W

=
=
=
=
=

Lamp/fixture data
Standard Weight
Spacing criteria
Wattage
ballast
lbs. kgs.
N C M S W
High pressure sodium (mog/clear)
150 (PG16A) CWA
32 15
0.7 0.8 1.1 1.4 1.6
200 (PG16A) CWA
35 16
– 0.8 1.3 1.7 2.0
250 (PG16A) CWA
35 16
– 0.8 1.3 1.7 2.0
400 (PG16A) CWA
38 17
– 1.2 1.4 1.7 2.0
400 (PG21A) CWA
55 25
– 1.1 – – –
1000 (PG21A) CWA
55 25
– – 1.6 –
Metal halide (mog/clear)
400 (PG16A) CWA
36 16
0.7 1.0 1.3 1.7 2.1
400 (PG21A) CWA
55 25
0.8 – – – –
1000 (PG21A) CWA
55 25
– 1.2 – – –

Narrow
Concentrating
Medium
Spread
Widespread

Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches
(centimeters) unless otherwise noted.

TPG PG16A
Overall height: 25-3/8 (64.5)
Reflector height: 15-1/2 (39.4)
Diameter: 17-1/2 (44.5)

www.lithonia.com, keyword: TPG-A

TPG PG21A
Overall height: 27-5/8 (70.2)
Reflector height: 19-1/2 (49.5)
Diameter: 22 (55.9)

LITHONIA INDOOR HID

400M
400M
1000M

Optical

355

HIGH BA
Y
BAY

Premium Enclosed Glass Optical

TPGE

Intended Use
For high mounting heights that require high efficiencies, horizontal and vertical illumination,
and premium contrast control. Optimum performance for high ambient temperatures and harsh
environments. Ideal for heavy manufacturing areas, retail, warehouse aisles and gymnasiums.

DuraBay™

Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – High-efficiency, high performance heatresistant borosilicate glass reflector mounted
within a heavy-gauge rigid wire form. Yields
high vertical foot candles with low brightness
and excellent contrast control. Cast-aluminum
upper enclosure and corrosion-resistant steel

PG16GLE

PG21GLE

Wattage

TPGE
150S
200S
250S
400S
400S
1000S

Optical
Distribution (select one)
High pressure sodium
PG16GLE
PG16GLE
PG16GLE
PG16GLE
PG21GLE
PG21GLE

–
–
–
–
–
–

C
C
C
C
C21
C21

M
M
M
M
–
–

S
S
S
S
–
–

Voltage
120
208 1,2
2401,2,3
277
347
480
TB4
TBV5

W
W
W
W
–
–

LITHONIA INDOOR HID

Metal halide

356

175M
200M
250M
320M
350M
400M
450M
350M
400M
450M
750M
875M
1000M

Installation – Cast-aluminum pendant splice box
threaded for ¾” conduit (standard). Other
mounting options available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient
HA option for 65°C). 750W, 875W and 1000W
pulse-start -30°C to 40°C.

PG16GLE
G16GLE
PG16GLE
PG16GLE
PG16GLE
PG16GLE
PG16GLE
PG21GLE
PG21GLE
PG21GLE
PG21GLE
PG21GLE
PG21GLE

N
C
N
C
N
C
N
C
N
C
N
C
N
C
N21 –
N21 –
N21 –
N21 –
N21 –
– C21

M
M
M
M
M
M
M
–
–
–
–
–
–

S
S
S
S
S
S
S
–
–
–
–
–
–

W
W
W
W
W
W
W
–
–
–
–
–
–

Ballast

Options/Accessories

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are available
with luminaires. Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

N
C
M
S
W

= Narrow
= Concentrating
= Medium
= Spread
= Widespread

Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in
inches (centimeters) unless otherwise noted.

TPGE PG16GLE
Overall height: 26-1/2 (67.3)
Reflector height: 15-1/2 (39.4)
Diameter: 17-1/2 (44.5)

Socket – Glazed porcelain, vertically oriented,
mogul base socket with copper alloy, nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV. 5KV pulse rated for 1000S.

Example: TPGE 400M PG16GLE M TB SCWA

Ordering Information

Series

flange and clear tempered glass lens are fully
gasketed. Lens assembly hinged and triple
latched for tight seal and easy maintenance.

TPGE PG21GLE
Overall height: 28-1/2 (72.4)
Reflector height: 19-1/2 (49.5)
Diameter: 22 (55.9)

www.lithonia.com, keyword: TPGE

Lamp/fixture data
Standard Weight
Wattage
ballast lbs. kgs. N
High pressure sodium (mog/clear)
150 (PG16GLE)
CWA
32 15
–
200 (PG16GLE)
CWA
35 16
–
250 (PG16GLE)
CWA
35 16
–
400 (PG16GLE)
CWA
38 17
–
400 (PG21GLE)
CWA
55 25
–
1000 (PG21GLE) CWA
55 25
–
Metal halide (mog/clear)
175 (PG16GLE)
CWA
36 16 0.6
250 (PG16GLE)
CWA
36 16 0.6
400 (PG16GLE)
CWA
38 17 0.7
400 (PG21GLE)
CWA
55 25 0.9
1000 (PG21GLE) CWA
55 25
–

Spacing criteria
C M S W
0.9
0.9
0.9
0.8
1.0
1.4

1.3
1.5
1.5
1.3
–
–

1.5
1.7
1.7
1.7
–
–

1.8
2.0
2.0
2.2
–
–

0.8
0.8
0.9
–
1.2

1.3
1.3
1.3
–
–

1.6
1.6
1.6
–
–

1.9
1.9
1.9
–
–

NOTES:
1 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
2 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
3 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
5 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).

PSG9

Premium Enclosed Shrouded Glass Optical
For high mounting heights that require high efficiencies, horizontal illumination and premium
contrast control. Optimum performance for high
ambient temperatures and harsh environments.
Ideal for heavy manufacturing areas, retail and
warehouse aisles.
Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory ttested. High power factor
ballast with a minimum of class H insulation.
Optics – High-efficiency, high performance heatresistant borosilicate glass reflector mounted in
heavy-gauge rigid wire form. Aluminum shroud
protects glass prisms from oily dirt accumulation,
emphasizing downward efficiency. Cast-aluminum upper enclosure, corrosion-resistant steel

Wattage

TPGE
150S
200S
250S
400S
400S
1000S
175M
200M
250M
320M
350M
400M
400M
750M
875M
1000M

Installation – Cast-aluminum pendant splice box
threaded for ¾” conduit (standard). Other
mounting options available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 65°C). 750W, 875W and 1000W pulsestart -30° C to 40° C.

PG16AGLE

PG21AGLE

Example: TPGE 400M PG16AGLE M 277 HOCS

Distribution (select one)
Optical
High pressure sodium
PG16AGLE
–
C
M S W
PG16AGLE
–
C
M S W
PG16AGLE
–
C
M S W
PG16AGLE
–
C
M S W
PG21AGLE
–
C21 – – –
PG21AGLE
–
C21 – – –
Metal halide
PG16AGLE
N
C
M S W
PG16AGLE
N
C
M S W
PG16AGLE
N
C
M S W
PG16AGLE
N
C
M S W
PG16AGLE
N
C
M S W
PG16AGLE
N
C
M S W
PG21AGLE
N21 –
– – –
PG21AGLE
N21 –
– – –
PG21AGLE
N21 –
– – –
PG21AGLE
–
C21 – – –

Voltage
120
208 1,2
240 1,2,3
277
347
480 1,2
TB4
TBV5

Ballast

Options/Accessories

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are available
with luminaires. Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

Lamp/fixture data
Standard Weight
Wattage
ballast lbs. kgs.
High pressure sodium (mog/clear)
150 (PG16AGLE) CWA 32 15
200 (PG16AGLE) CWA 35 16
250 (PG16AGLE) CWA 35 16
400 (PG16AGLE) CWA 38 17
400 (PG21AGLE) CWA 55 25
1000 (PG21AGLE) CWA 55 25
Metal halide (mog/clear)
175 (PG16AGLE) CWA 36 16
250 (PG16AGLE) CWA 36 16
400 (PG16AGLE) CWA 36 16
400 (PG21AGLE) CWA 55 25
1000 (PG21AGLE) CWA 55 25

Spacing criteria
N C M S W
–
–
–
–
–
–

0.8
1.6
1.6
1.2
1.0
0.8

1.2
1.8
1.8
1.6
–
–

1.5
2.0
2.0
1.8
–
–

1.8
2.2
2.2
2.0
–
–

–
–
0.8
0.8
–

1.3
1.3
1.2
–
1.1

1.5
1.5
1.4
–
–

1.7
1.7
1.6
–
–

2.0
2.0
1.9
–
–

= Narrow
= Concentrating
= Medium
= Spread
= Widespread

NOTES:
1 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
2 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
3 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
5 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).

Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches
(centimeters) unless otherwise noted.

TPGE PG16AGLE
Overall height: 26-1/8 (66.4)
Reflector height: 15-1/2 (39.4)
Diameter: 17-1/2 (44.5)

www.lithonia.com, keyword: TPGE-A

TPGE PG21AGLE
Overall height: 28-1/2 (72.4)
Reflector height: 19-1/2 (49.5)
Diameter: 22 (55.9)

LITHONIA INDOOR HID

N
C
M
S
W

PSG9

DuraBay™

Socket – Glazed porcelain, vertically oriented,
mogul base socket with copper alloy, nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV. 5KV pulse rated for 1000S.

Ordering Information

Series

TPGE

flange and clear tempered glass lens are fully
gasketed to inhibit entrance of ambient contaminants. Lens assembly is hinged and triple
latched for tight seal and easy maintenance.

HIGH BA
Y
BAY

Intended Use

357

HIGH BA
Y
BAY

Open Acrylic Optical

TH PA22
TH PA25

Intended Use

ing approximately 15–20% uplight. Open opticals are self cleaning – ventilated design carries
contaminants out top of reflector. Enclosed optical utilizes clear, tempered-glass lens. Hinged
and latched for easy maintenance. Coated lamps
provide optimum performance.

For high mounting heights that require higher
efficiencies, general horizontal/high vertical illumination and premium contrast control. Ideal
for light manufacturing areas, warehouse and retail aisles. Certain airborne contaminants can
diminish integrity of acrylic. Refer to Acrylic
Environmental Compatibility Chart on page
735 for suitable uses.

Acrylume®

Socket – Glazed porcelain, vertically-oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. Protected
version with pink exclusionary socket. UL Listed
1500W, 600V, 4KV pulse rated.

Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.

Installation – Pendant splice box (PSB) threaded
for ¾” conduit (standard). Other mounting options available. Protect reflector from breakage. Use full wire guard (FWG) option for
areas where reflectors are susceptible to
impact.

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
PA22

Listings

Optics – UV-stabilized, high-efficiency, high-performance acrylic reflector yields high vertical
footcandles while maintaining low brightness.
Optical assembly is fully adjustable & accommodates a range of light distributions, while provid-

UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations.

PA25

Example: TH 350MP PA22 TB SCWA FWG

Ordering Information
Series

LITHONIA INDOOR HID

TH

358

Wattage

Voltage

Optical

High pressure sodium
250S
PA16
250S
PA22 or PA22N
250S
PA22L2
400S
PA22 or PA22N
400S
PA22L2
1000S
PA25
Metal halide protected1
200MP
PA22, PA22N orPA22SP
250MP
PA22, PA22N or PA22SP
320MP
PA22, PA22N orPA22SP
350MP
PA22, PA22N or PA22SP
400MP
PA22, PA22N or PA22SP
450MP
PA22, PA22N or PA22SP
875MP
PA25
1000MP
PA25
Metal halide
175M
PA22E3
200M
PA22E3
250M
PA22E3
400M
PA22, PA22N or PA22SP
400M
PA22L2
1000M
PA25

120
208 4,5
2404,5,6
277
347
480 4,5
TB7
TBV8

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

Options/
Accessories
See pages 386-397.
HID lamps are
available with
luminaires.
Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast (175400W)
SCWI Isolated SCWA (400W)

Lamp/fixture
Standard
Wattage
ballast
High pressure sodium (mog/coated)
250 (PA16)
CWA
400 (PA22)
CWA
250 (PA22N)
CWA
400 (PA22N)
CWA
1000 (PA25)
CWA
Metal halide (mog/coated)
175 (PA22E)
CWA
250 (PA22E)
CWA
400 (PA22)
CWA
400 (PA22N)
CWA
400 (PA22SP)
CWA
1000 (PA25)
CWA

data
Weight
lbs. kgs.

S/mtg.
height

21
35
21
35
48

10
16
10
16
22

1.2 to 1.9
1.3 to 2.0
0.8 to 2.0
0.8 to 2.0
1.3 to 2.2

20
22
31
31
31
40

9
10
14
14
14
18

1.3 to 2.0
1.3 to 2.0
1.2 to 2.1
0.8 to 2.1
0.8 to 2.1
1.6 to 2.2

See pages 384-385 for details.
PA16
PA22N
PA22SP
PA22E
PA22L
PA25

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.
TH PA16
Reflector height:
10-3/4 (27.3)
Varies with distribution.
Overall height:
20-5/8 to 26 (52.4 to 66)
Diameter: 16-1/4 (41.3)

Ballast

TH PA22/ PA22L
Reflector height:
13-1/2 (34.3)
Varies with distribution.
Overall height:
20-5/8 to 26 (52.4 to 66)
Diameter: 22-3/8 (56.8)

=
=
=
=
=
=

Standard
Narrow
Concentrated
Standard
Standard
Standard

Ambient Parameters

-30° to 25°C
(-22° to 131°F)

TH250SPA16, PA22/PA22N/PA22SP
TH175M, 250MPA22E
TH 400M, 400S PA22/PA22N/PA22SP
TH400M, 400SPA22L
TH1000M, 1000SPA25

NOTES:
1 See page 385 for details on protected sockets.
2 Lensed bottom, open top. Periodic cleaning maintains performance. Does not
meet UL lamp rupture containment.
3 Enclosed bottom, open top. Meets UL lamp rupture containment standards.
Periodic cleaning maintains performance.
4 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
5 Requires CWIor MRB option in Canada for high pressure sodium. Available for
70-400W only.
6 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
7 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
8 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).
TH PA25
Reflector height: 14 (35.6)
Varies with distribution.
Overall height:
23 to 26-3/8 (58.4 to 62)
Diameter: 25-1/2 (64.8)

www.lithonia.com, keywords: TH-PA22 or TH-PA25

-30° to 40°C
(-22° to 77°F)

-30° to 55°C
(-22° to 104°F)

■
■
■

■
■

■ = COMPATABILITY

Express delivery products.
See page11 for details about LightQuick XD.
Description
TH 400 PA22 TB

PSG9

Open Acrylic Optical

For high mounting heights that require higher
efficiencies, high horizontal/vertical illumination
and premium contrast control. Ideal for light
manufacturing areas, warehouse and retail aisles.
Steel ballast housings should be used in areas
with minimal airborne contaminants. Certain
airborne contaminants can diminish integrity
of acrylic. Refer to Acrylic Environmental Compatibility Chart on page 735 for suitable uses.
Features
Housing – Steel housing with white polyester
powder coat finish. All electrical components
are positioned to assure unit will hang
straight. Housing is ventilated for optimal
thermal performance.
Ballast – Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only
from 200-277V.
Optics – UV-stabilized, high-efficiency, high-performance acrylic refractor yields high horizontal

footcandles while maintaining low brightness.
Optical assembly is fully adjustable, accommodates a range of light distributions while providing approximately 15–20% uplight. Self-cleaning, ventilated design carries optical contaminants out top of refractor. Coated lamps provide
optimum performance.

Wattage

SH

Metal halide protected1
320MP
350MP
400MP
Metal halide
400M

Acrylume®

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.
Installation – One-piece galvanized hook and
spring steel latch with cord and plug (SC3P) standard. Pendant splice box with top entry for 3/4”
conduit also available with other mounting options. Protect reflector from breakage. Use full
wire guard (FWG) option for areas where
reflectors are susceptible to impact.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 40°C (High Ambient HA
option for 55°C).

PA22

Example: SH 400M PA22 277 GEB SC3P

Ordering Information
Series

SH PA22

Voltage

Optical
PA22
PA22N
PA22SP

Standard
Narrow
Concentrated

208
240
277
TVOLT1

Ballast

Pulse Start H.I.D. Ballast/Lamp Systems

Options/Accessories
See pages 386-397. HID lamps are available with luminaires. Consult factory.

Pulse start metal halide
GEB Electronic ballast
See pages 384-385 for details.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
Metal halide (mog/coated)
400 (PA22)
GEB
14 6.5
400 (PA22N)
GEB
14 6.5
400 (PA22SP)
GEB
14 6.5

S/mtg.
height
1.2 to 2.1
0.8 to 2.1
0.8 to 2.1

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

SH 400M PA22/PA22N/PA22SP

-30° to 25°C
(-22° to 77°F)

-30° to 40°C
(-22° to 104°F)

-30° to 55°C
(-22° to 131°F)

■
■ = COMPATABILITY

PSG9

www.lithonia.com, keyword: SH-PA22

Reflector height: 13-1/2 (34.3)
Diameter: 22-3/8 (56.8)
Overall height: 20-5/8 to
26 (52.4 to 66)
Varies with distribution.

LITHONIA INDOOR HID

NOTES:
1 See page 385 for details on protected sockets.
2 Tri-volt electronic ballast capable of operating on any line voltage between 200V
and 277V at 50 or 60 Hz. Pendant splice box (PSB) mounting required.

Ambient Parameters

HIGH BA
Y
BAY

Intended Use

359

LOW BA
Y
BAY

Premium Enclosed Acrylic Optical

TX PA22GLE
TX PA25ALE
Acrylume®

Intended Use
For controlled environments that require vertical and high horizontal illumination. Ideal for retail areas, light manufacturing areas and aisles.
Certain airborne contaminants can diminish
integrity of acrylic. Refer to Acrylic Environmental Compatibility Chart on page 735 for
suitable uses.
Features

PA25ALE

Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available. Protect reflector from breakage. Use
full wire guard (FWG) option for areas where
reflectors are susceptible to impact.

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.

Listings

LITHONIA INDOOR HID

TX

360

Wattage

Optical

High pressure sodium, 22" glass lens
50S
PA22GLE
400S
PA22GLE
High pressure sodium, 25" acrylic lens
250S
PA25ALE
400S
PA25ALE
Metal halide, 22" glass lens
175M
PA22GLE
200M
PA22GLE
250M
PA22GLE
320M
PA22GLE
350M
PA22GLE
400M
PA22GLE
450M
PA22GLE
Metal halide, 25" acrylic lens
200M
PA25ALE
250M
PA25ALE
320M
PA25ALE
350M
PA25ALE
400M
PA25ALE
450M
PA25ALE

Ballast

Voltage
120
208 1,2
240 1,2,3
277
347
480 2
TB4
TBV5

Options/Accessories

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are available with
luminaires. Consult factory.
Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
250(PA22GLE)
CWA
33
15
400(PA22GLE)
CWA
36
16
250(PA25ALE)
CWA
39
18
400(PA25ALE)
CWA
39
18
Metal halide (mog/clear)
250(PA22GLE)
CWA
30
14
400(PA22GLE)
CWA
33
15
250(PA25ALE)
CWA
35
16
400(PA25ALE)
CWA
35
16

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See page 384-385 for details.

Ambient Parameters
TX 250S, 250M PA22GLE
TX 400S, 400M PA22GLE
TX 250S, 250M PA25ALE
TX 400S, 400M PA25ALE
TX 450M PA25ALE

-30° to 25°C
(-22° to 77°F)

-30° to 40°C
(-22° to 104°F)

■
■
■

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

TX PA22GLE
Overall height: 24-1/2 (62.2)
Reflector height: 17-1/2 (44.5)
Diameter: 23-3/8 (59.4)

UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations.
-30°C to 40°C ambient operations (High Ambient
HA option for 55°C).

Example: TX 400M PA22GLE 277 SCWA HOCS

Ordering Information

Series

Socket – Glazed porcelain, vertically oriented
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated.

Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.

Optics – Injection-molded, virgin acrylic reflector with clear, tempered glass lens enclosure.
UV-stabilized reflector. Lens is tempered glass
for 22" reflector and flat clear acrylic for 25" reflector. Hinge and lens retainer latches facilitate
tool-less removal for maintenance and cleaning.

PA22GLE

Totally enclosed, gasketed lens and reflector inhibit the entrance of ambient contaminants.
Meets UL lamp rupture containment specifications. Coated lamps provide optimum performance.

TX PA25ALE
Overall height: 26-3/8 (66.9)
Reflector height: 15-3/8 (38)
Diameter: 25-3/4 (65.4)

www.lithonia.com, keywords: TX-PA22GLE and TX-PA25ALE

S/mtg.
height
1.6
1.6
1.1
1.1
1.7
1.7
1.2
1.2

-30° to 55°C
(-22° to 131°F)

■
■

■ = COMPATABILITY

NOTES:
1 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
2 Requires CWI or MRB option in Canada for HP. Available for 70-400W only.
3 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
5 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).

PSG9

Premium Enclosed Acrylic Optical
For controlled environments that require a balance between high vertical and horizontal illumination. Ideal for retail areas, light manufacturing areas and aisles. Certain airborne contaminants can diminish integrity of acrylic. Refer to
Acrylic Environmental Compatibility Chart on
page 735 for suitable uses.
Features
Housing: Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – Injection-molded, virgin acrylic reflector and drop (PA25D) or conical (PA22C) lens. UV
stabilized. Hinge and lens retainer latches facilitate tool-less removal for maintenance and
cleaning. Totally enclosed, gasketed refractor

and reflector inhibit the entrance of ambient
contaminants. Meets UL lamp rupture containment specifications. Coated lamps provide optimum performance.
Socket – Glazed porcelain, vertically oriented
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated.

TX PA22C
TX PA25D

LOW BA
Y
BAY

Intended Use

Acrylume®

Installation: Pendant splice box threaded for ¾”
conduit (standard). Other mounting options
available. Protect reflector from breakage. Use
full wire guard (FWG) option for areas where
reflectors are susceptible to impact.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations.
-30°C to 40°C ambient operations. UL wet location available.

PA22C

PA25D

Example: TX 400M PA22C 120 SF QRS

Ordering Information

Series
TX

Wattage

Optical

120
208 1,2
240 1,2,3
277
347
480 1,2
TB4
TBV5

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See page 384-385 for details.

NOTES:
1 Requires CWI option in Canada for metal halide, available for 175-450W only.
Not available for 250W in 480V.
2 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
3 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
5 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).

Options/Accessories
See pages 386-397. HID lamps are available
with luminaires. Consult factory.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium(mog/coated)
250 (PA22C)
CWA
31 14
250 (PA25D)
CWA
34 15
400 (PA22C)
CWA
31 14
400 (PA25D)
CWA
34 15
Metal halide (mog/coated)
250 (PA22C)
CWA
31 14
250 (PA25D)
CWA
31 13
350 (PA22C)
CWA
31 14
350 (PA25D)
CWA
31 13
400 (PA22C)
CWA
31 14
400 (PA25D)
CWA
30 13

Overall height: 22-3/4 (57.8)
Refractor height: 15-3/4 (40)
Diameter: 22-3/8 (56.8)

TX250S,250MPA22C
TX250S,250MPA25D
TX400S,400MPA22C
TX400S,400MPA25D

PSG9

-30° to 25°C
(-22° to 77°F)

-30° to 40°C
(-22° to 104°F)

■
■
■
■

-30° to 55°C
(-22° to 131°F)

■ = COMPATABILITY

www.lithonia.com, keywords: TX-PA22C and TX-PA25D

2.7
2.4
2.7
2.4
3.0
2.8
2.8
2.5
2.8
2.8

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

TX PA22C

Ambient Parameters

S/mtg.
height

TX PA25D
Overall height: 22-1/8 (56.2)
Refractor height: 17-1/8 (43.5)
Diameter: 25-1/2 (64.8)

LITHONIA INDOOR HID

High pressure sodium, 22" acrylic conical lens
250S
PA22C
400S
PA22C
High pressurem sodium, 25" acrylic drop lens
250S
PA25D
400S
PA25D
Metal halide, 22" acrylic conical lens
175M
PA22C
200M
PA22C
250M
PA22C
320M
PA22C
350M
PA22C
400M
PA22C
450M
PA22C
Metal halide, 25" acrylic drop lens
175M
PA25D
200M
PA25D
250M
PA25D
320M
PA25D
350M
PA25D
400M
PA25D
450M
PA25D

Ballast

Voltage

361

HIGH BA
Y
BAY

Premium Open Aluminum Optical

TH A 17
TH A 22

Intended Use
For high mounting heights that require high efficiencies, horizontal illumination and premium
glare control. Ideal for manufacturing areas and
aisles.
Features

Hi-Tek®

Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and
heat-sinked to ballast housing for cool operation.
Ballast –100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – Premium spun aluminum, anodized reflector combines high efficiency with extended
shielding angles for high performance. Exclusive
fluted design minimizes arc tube voltage rise.
Optical system is adjustable and accommodates

A22

the full range of industrial light distributions.
Self-cleaning, ventilated design carries optical
contaminants out through open top of reflector.
Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. 5KV pulse rated
for 1000S. Protected version with pink exclusionary socket.
Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 65°C). 875W and 1000W pulse-start 30°C to 40°C.

A17

Example: TH 400M A17 277 SCWA F1

Ordering Information

Series

Wattage

TH

Optical

High pressure sodium
70S
100S
150S
200S
250S
400S
1000S

A17
A17
A17
A17
A17
A17
A22
Metal halide protected1

175MP
200MP
250MP
320MP
350MP
400MP
450MP
875MP
1000MP

A17
A17
A17
A17
A17
A17
A17
A22
A22
Metal halide

LITHONIA INDOOR HID

400M
1000M

362

A17
A22

Voltage
120
208 2,3
240 2,3,4
277
347
480 2,3
TB5
TBV6

Ballast

Options/Accessories

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are availabel with
luminaires. Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

NOTES:
1 See page 385 for details on protected sockets.
2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
3 Requires CWIor MRBoption in Canada for high pressure sodium. Available for
70-400W only.
4 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
6 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000 W metal halide and high pressure sodium (CWA only).

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
70
HX-HPF
16
8
100
HX-HPF
17
8
150
HX-HPF
17
8
200
CWA
19
9
250
CWA
21
10
400 (A17)
CWA
33
15
1000 (A22)
CWA
56
26
Metal halide (mog/clear)
400 (A17)
CWA
25
11
1000 (A22)
CWA
45
21

S/mtg.
height
0.9 to 1.8
0.9 to 1.8
0.9 to 1.8
0.8 to 2.0
0.8 to 2.0
0.8 to 1.9
0.8 to 1.6
0.8 to 1.8
1.0 to 1.9

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.
TH A22
Overall height: 23-1/2 to
25 (59.7 to 63.5).
Varies with distribution.
Reflector height: 12-1/4 (31.1)
Diameter: 23-1/4 (59.1)

TH A17
Overall height: 21-1/2 to
23-1/2 (54.6 to 59.7).
Varies with distribution.
Reflector height: 12-1/8 (30.8)
Diameter: 17-7/8 (45.4)

www.lithonia.com, keywords: TH-A17 or TH-A22

PSG9

Premium Enclosed Aluminum Optical
For high-mounting heights that require high efficiencies, horizontal illumination, premium
glare control and total enclosure. Ideal for heavy
manufacturing areas, gymnasiums and wet location applications.
Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components are horizontally opposed and
heat-sinked to ballast housing for cool operation.

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. 5KV pulse rated
for 1000S. Protected version with pink exclusionary socket.

Hi-Tek®

Installation – Pendant splice box (PSB) is threaded for ¾” conduit (standard). Other mounting
options available.

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – One-piece, totally enclosed-and-gasketed spun aluminum, anodized reflector combines high efficiency with extended shielding
angle for high-performance optical control. Exclusive fluting design minimizes arc tube volt-

TE E17
TE E22

age rise. Gasketed, clear, tempered-glass lens inhibits the entrance of ambient contaminants.
Hinge and lens retainer latches for tool-less access.

HIGH BA
Y
BAY

Intended Use

Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 65°C). 875W and 1000W pulse-start 30° C to 40° C.

E22
E17

Example: TE 400M E17 M TB SCWA

Ordering Information

Series

Wattage

TE
70S
100S
150S
200S
250S
400S
400S
1000S
175M
200M
250M
320M
350M
400M
350M
400M
450M
750M
875M
1000M

Optics

Distribution (select one)

High pressure sodium
E17
N
C
E17
N
C
E17
–
C
E17
N
C
E17
N
C
E17
– –
E22
N
C
E22
N
C
Metal halide
E17
–
C
E17
–
C
E17
–
C
E17
– –
E17
– –
E17
– –
E22
N
C
E22
N
C
E22
N
C
E22
N
C
E22
N
C
E22
–
C

S
S
S
S
S
S
–
–

W
W
W
W
W
W
–
–

M
M
M
M
M
M
–
–
–
–
–
M

S
S
S
S
S
S
–
–
–
–
–
S

W
W
W
W
W
W
–
–
–
–
–
–

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

Options/Accessories
See pages 386-397. HID lamps are availabel
with luminaires. Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse
start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

= Narrow
= Concentrated
= Medium
= Spread
= Widespread

NOTES:
1 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
2 Requires MRB or CWI option in Canada for high pressure sodium. Available for
70-400W only.
3 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
5 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W and 1000W metal halide or high pressure sodium (CWA only).

PSG9

120
208 1,2
2401,2,3
277
347
480 1,2
TB4
TBV5

Lamp/fixture data
Standard
Wattage ballast

Weight
lbs. kgs.

High pressure sodium (mog/clear)
70
HX-HPF
21 10
100
HX-HPF
21 10
150
HX-HPF
21 10
200
CWA
22 10
250
CWA
26 12
400
CWA
41 19
400
CWA
39 18
1000
CWA
65 29
Metal halide (mog/clear)
175
CWA
22 10
250
CWA
24 11
400
CWA
31 14
400
CWA
31 14
1000
CWA
50 23

Spacing/mounting height
E17N E17C E17M E17S E17W E22N E22C E22M E22S
–
–
–
0.8
0.8
–
–
–

1.0
1.0
1.0
1.1
1.1
–
–
–

1.3
1.4
1.3
1.3
1.3
–
1.2
–

1.5
1.5
1.6
1.5
1.5
–
1.5
–

1.9
1.9
1.8
1.9
1.9
–
1.9
–

–
–
–
–
–
0.8
–
0.8

–
–
–
–
–
1.1
–
1.0

–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–

–
–
–
–
–

1.0
1.0
–
–
–

1.4
1.3
–
1.4
–

1.6
1.6
–
1.6
–

2.0
1.9
–
1.9
–

–
–
0.8
–
–

–
–
1.0
–
1.0

–
–
–
–
1.3

–
–
–
–
1.6

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

TE E17
Overall height: 24-3/8 (61.9)
Reflector height: 17-3/8 (44.1)
Diameter: 17-7/8 (45.4)

www.lithonia.com, keywords: TE-E17 or TE-E22

TE E22
Overall height: 24-3/8 (61.9)
Reflector height: 17-3/8 (44.1)
Diameter: 23 (58.4)

LITHONIA INDOOR HID

N
C
M
S
W

M
M
M
M
M
M
–
–

Voltage

363

HIGH BA
Y
BAY

Open or Lensed Aluminum Optical

TH A16
TH A16 GL

Intended Use
For high mounting heights that require high efficiencies and horizontal illumination. Ideal for
general manufacturing areas, storage areas and
warehouse aisles.
Features

Hi-Tek®

Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.

features a gasketed clear tempered glass lens
with hinge and stainless steel latches for easy
tool-less access.
Socket – Glazed porcelain, vertically oriented
mogul-base socket with copper alloy nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.
Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – High-efficiency, anodized, spun aluminum reflector with exclusive fluted design that
minimizes arc-tube voltage rise for optimal
lamp life. Open A16 opticals are self cleaning
with a ventilated design that carries contaminants out top of reflector. Lensed A16GL optical

A16

Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 65°C). A16GL meets UL lamp rupture
containment specifications.

A16GL

Example: TH 400MP A16 277 HOCS

Ordering Information
Series

LITHONIA INDOOR HID

TH
THD1

364

Wattage

Optical

High pressure sodium
70S
A16
100S
A16
150S
A16
200S
A16
250S
A16
250S
A16GL
400S
A16
400S
A16GL
Metal halide protected2
175MP
A16
200MP
A16
250MP
A16
320MP
A16
350MP
A16
400MP
A16
450MP
A16
Metal halide
175M
A16GL
200M
A16GL
250M
A16GL
320M
A16GL
350M
A16GL
400M
A16
400M
A16GL
450M
A16GL

Ballast

Voltage

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

120
208 3,4
240 3,4,5
277
347
480 3,4
TB6
TBV7

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

THD1

Options/Accessories
See pages 386-397. HID lamps are available with luminaires. Consult factory.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
70
HX-HPF
12 5
100
HX-HPF
13 5
150
HX-HPF
14 6
200
CWA
14 6
250
CWA
17 8
400
CWA
25 11
Metal halide (mog/clear)
175
CWA
16 7
250
CWA
20 9
400
CWA
21 10

S/mtg.
height
0.9 to 1.8
0.9 to 1.8
0.9 to 1.8
1.1 to 1.9
1.1 to 1.9
1.1 to 2.0
1.2 to 2.1
1.2 to 2.1
1.2 to 1.9

Express delivery products.
Unitized Distributor Pack

See page11 for details about LightQuick XD.
Description

NOTES:
1 THD consists of TH housing and A16 reflector shippedin one carton. Available
with tapped ballast or 480V only. Available only in 400S, 320 MP, 400MP and
400M.
2 See page 385 for details on protected sockets.
3 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
4 Requires CWIor MRB option in Canada for high pressure sodium. Available for
70-400W only.
5 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
6 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
7 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W metal halide or high pressure sodium (CWA only).

TH 400M A16 TB

TH A16
Overallheight: 17-1/4to 20(43.8to50.8).
Varies with distribution.
Reflector height: 9-1/2 (24.1)
Diameter: 16 (40.6)

TH A16GL
Overall height: 17-1/4 to 20 (43.8 to 50.8).
Varies with distribution.
Reflector height: 10-1/2 (26.7)
Diameter: 17-1/4 (43.8)

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

www.lithonia.com, keywords: TH-A16 or TH-A16GL

PSG9

Open or Lensed Aluminum Optical
For high mounting heights that require high efficiencies and horizontal illumination. Ideal for
storage areas and warehouse aisles. Steel ballast
housings should be used in areas with minimal
airborne contaminants.

Socket – Glazed porcelain, vertically-oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.

Features
Housing – Steel housing with white polyester
powder coat finish. All electrical components
are positioned to assure unit will hang straight.
Housing is ventilated for optimal thermal performance.

Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 40°C (High Ambient HA
option for 55°C). A16GL meets UL lamp rupture
containment specifications.

Optics – High-efficiency, anodized, spun aluminum reflector with exclusive fluted design that
minimizes arc-tube voltage rise for optimal lamp
life. Open A16 optical is self-cleaning with a ventilated design that carries contaminants out top

A16
A16GL

Example: SH 400M A16 208 GEB SC3P

Ordering Information

Optical

Wattage

SH

Hi-Tek®

Installation – One-piece galvanized hook and
spring steel latch with cord and plug (SC3P) is
standard. Pendant splice box (PSB) with top entry
for ¾” conduit also available with other mounting options.

Ballast – Electronic ballast is 100% factory tested and UL Listed. Ballast will operate pulse start
lamps only from 200-277V.

Series

SH A16
SH A16 GL

of reflector. Lensed A16GL optical features a gasketed clear tempered glass lens with hinge and
stainless steel latches for easy tool-less access.

HIGH BA
Y
BAY

Intended Use

Metal halide protected
320MP
350MP
400MP

1

A16
A16
A16

Voltage
208
240
277
TVOLT2

Options/Accessories

Ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
GEB Electronic ballast

See pages 386-397. HID lamps are
available with luminaires. Consult
factory.

Metal halide
320M
350M
400M
400M

A16GL
A16GL
A16GL
A16

See pages 384-385 for details.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
Metal halide (mog/clear)
400
GEB
12 5.5

S/mtg.
height
1.2 to 1.9

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

NOTES:
1 See page 385 for details on protected sockets.
2 Tri-volt electronic ballast capable of operating on any line voltage between
200V and 277V at 50 or 60 Hz (available with GEB option only). Pendant splice
box (PSB) mounting required.

PSG9

www.lithonia.com, keywords: SH-A16 or SH-A16GL

SH A16GL
Overall height: 21 to
24-1/4 (53.3 to 61.6).
Varies with distribution.
Reflector height: 10-1/2 (26.7)
Diameter: 17-1/4 (43.8)

LITHONIA INDOOR HID

SH A16
Overall height: 21 to
24-1/4 (53.3 to 61.6).
Varies with distribution.
Reflector height: 9-1/2 (24.1)
Diameter: 16 (40.6)

365

HIGH BA
Y
BAY

Open Aluminum Optical

TH A15

Intended Use
For high mounting heights that require high efficiencies and horizontal illumination. Ideal for
general manufacturing areas, storage areas and
warehouse aisles.

Hi-Tek®

Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.

plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.
Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 65°C).

Optics – High-efficiency, anodized, spun aluminum reflector with exclusive fluted design that
minimizes arc-tube voltage rise for optimal
lamp life. Self-cleaning ventilated design that
carries contaminants out top of reflector.
Socket – Glazed porcelain, vertically-oriented,
mogul-base socket with copper alloy, nickel-

A15

Example: TH 400MP A15 TB

LITHONIA INDOOR HID

Ordering Information

366

Series

Wattage

Optical

TH
THD1

High pressure sodium
70S
100S
150S
200S
250S
400S
Metal halide protected2
175MP
200MP
250MP
320MP
350MP
400MP
450MP
Metal halide
400M

A15

Voltage

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

THD1
TH A15
Overall height:
250/400S: 19-1/2 (49.5)
400M: 21-1/4 (54.0)
Reflector height: 9 (22.9)
Diameter: 14-3/4 (37.5)

Options/Accessories

Ballast

120
208 3,4
240 3,4,5
277
347
480 3,4
TB6
TBV7

Unitized Distributor Pack

www.lithonia.com, keyword: TH-A15

See pages 384-385. HID lamps are available with luminaires.
Consult factory.

Express delivery products.
See page11 for details about LightQuick XD.
Description
TH 400M A15 TB

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
250
CWA
17
8
400
CWA
25 11
Metal halide (mog/clear)
400
CWA
21 10

S/mtg.
height
1.5
1.5
1.7

NOTES:
1 THD consists of TH housing and A15 reflector shipped in one carton. Available
with tapped ballast or 480V only. Available only in 400S, 320 MP, 400MP and
400M.
2 See page 385 for details on protected sockets.
3 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
4 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
5 220V and 240V 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
6 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada.)
7 Optional five-tap ballast (120V,208V,240V,277V,480V). Available for 250W,
400W and 1000W metal halide (CWA only).

PSG9

Open Aluminum Optical
For high mounting heights that require high efficiencies and horizontal illumination. Ideal for
general manufacturing areas, storage areas and
warehouse aisles. Steel Ballast Housing (SH)
should be used in areas with minimal airborne
contaminants.
Features
Housing – Steel housing with white polyester
powder coat finish. All electrical components
are positioned to assure unit will hang straight.
Housing is ventilated for optimal thermal performance.
Ballast – Electronic ballast is 100% factory tested
and UL Listed. Ballast will operate pulse start
lamps only from 200-277V.

SH A15

Socket – Glazed porcelain, vertically-oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.

Hi-Tek®

Installation – One-piece galvanized hook and
spring steel latch with cord and plug (SC3P) is
standard. Pendant splice box (PSB) with top entry
for ¾” conduit also available with other mounting options.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 40° (High Ambient HA
option for 55°C).

Optics – High-efficiency, anodized, spun aluminum reflector with exclusive fluted design that
minimizes arc-tube voltage rise for optimal lamp
life. Self-cleaning ventilated design carries contaminants out top of reflector.

A15

Example: SH 400M A15 TVOLT GEB PSB

Ordering Information

Series
SH

Wattage
Metal halide protected
320MP
350MP
400MP
Metal halide
400M

HIGH BA
Y
BAY

Intended Use

1

Optical

Voltage

A15

208
240
277
TVOLT2

Options/Accessories

Ballast

See pages 386-397. HID lamps are available with
luminaires. Consult factory.
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
GEB Electronic ballast
See pages 384-385 for details.

Lamp/fixture data
Wattage

Standard
ballast

Metal halide (mog/clear)
400
GEB

Weight
lbs. kgs.
12

5.5

S/mtg.
height
1.7

NOTES:
1 See page 385 for details on protected sockets.
2 Tri-volt electronic ballast capable of operating on any line voltage between
200V and 277V at 50 or 60 Hz. Pendant splice box (PSB) mounting required.

PSG9

www.lithonia.com, keyword: SH-A15

SH A15
Overall height:
250/400S: 19-1/2 (49.5)
400M: 21-1/4 (54.0)
Reflector height: 9 (22.9)
Diameter: 14-3/4 (37.5)

LITHONIA INDOOR HID

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

367

HIGH BA
Y
BAY

Premium Open Aluminum Optical

TH A14
Hi-Tek®

Intended Use

ed screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.

For high-mounting heights that require high efficiencies, horizontal illumination and vertical illumination. Ideal for manufacturing and warehouse aisles.

Installation – Pendant splice box is threaded for
¾” conduit (standard). Other mounting options
available.

Features

Listings

Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components are horizontally opposed and
heat-sinked to ballast housing for cooler operation.

UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 55°C (High Ambient HA
option for 65°C.)

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – One-piece hydroformed, anodized aluminum reflector provides rectangular distribution for maximum luminaire spacing and vertical
illumination.
Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy nickel-platA14

Example: TH 320MP A14 TB SCWA KW1S

LITHONIA INDOOR HID

Ordering Information

368

Series

Wattage

Optical

TH

High pressure sodium
150S
200S
250S
400S
Metal halide protected1
175MP
200MP
250MP
320MP
350MP
400MP
450MP
Metal halide
400M

A14

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.
TH A14
Overall height: 17-3/4 to 19-1/2 (45.1 to 49.5).
Varies with distribution.
Reflector height: 8-1/2 (21.6)
Diameter: 17-3/4 (45.1)

Voltage
120
208 2,3
2402,3,4
277
347
480 2,3
TB5
TBV6

Options/Accessories

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are available
with luminaires. Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See page384-385 for details.

NOTES:
1 See page 385 for details on protected sockets.
2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
3 Requires CWIor MRBoption in Canada for high pressure sodium. Available for
70-400W only.
4 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
6 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W metal halide and high pressure sodium (CWA only).

www.lithonia.com, keyword: TH-A14

Lamp/fixture
Standard
Wattage
ballast
High pressure sodium (mog/clear)
150
HX-HPF
200
HX-HPF
250
CWA
400
CWA
Metal halide (mog/clear)
400
CWA

data
Weight
lbs. kgs.

S/mtg.
height

16
16
19
27

7
7
9
12

2.7
2.5
2.5
2.5

23

10

2.4

PSG9

Premium Open Aluminum Optical

SH A14

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated. Protected version with pink exclusionary socket.

For high-mounting heights that require high efficiencies, horizontal illumination and high vertical
illumination. Ideal for manufacturing and warehouse aisles. Steel ballast housings should be used
in areas with minimal airborne contaminants.

Hi-Tek®

HIGH BA
Y
BAY

Intended Use

Installation – One-piece galvanized hook and
spring steel latch with cord and plug (SC3P) is
standard. Pendant splice box (PSB) with top entry for ¾” conduit also available with other
mounting options.

Features
Housing – Steel housing with white polyester
powder coat finish. All electrical components
are positioned to assure unit will hang straight.
Housing is ventilated for optimal thermal performance.

Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 40°C (High Ambient HA
option for 55°C).

Ballast – Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only
from 200-277V.
Optics – One-piece hydroformed, anodized aluminum reflector provides rectangular distribution for maximum luminaire spacing and high
illumination.

A14

Example: SH 400M A14 277 GEB

Ordering Information

Series

Wattage

Optical

Voltage

SH

Metal halide protected1
320MP
350MP
400MP
Metal halide
400M

A14

208
240
277
TVOLT2

Options/Accessories

Ballast
Pulse Start H.I.D. Ballast/Lamp Systems

See pages 386-397. HID lamps are available with luminaires. Consult factory.

Pulse start metal halide
GEB Electrionic ballast
See pages 384-385 for details.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
Metal halide (mog/clear)
400
GEB
12 5.5

S/mtg.
height
2.4

NOTES:
1 See page 385 for details on protected sockets.
2 Tri-volt electronic ballast capable of operating on any line voltage between 200V
and 277V at 50 or 60 Hz. Pendant slice box (PSB) mounting required.

PSG9

www.lithonia.com, keyword: SH-A14

SH A14
Overall height: 17-3/4 to 19-1/2 (45.1 to 49.5).
Varies with distribution.
Reflector height: 8-1/2 (21.6)
Diameter: 17-3/4 (45.1)

LITHONIA INDOOR HID

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

369

LOW BA
Y
BAY

Premium Enclosed Aluminum Optical

TX A20
TX A26

Intended Use
For areas that require good vertical illumination
with excellent glare control at low mounting
heights. Ideal for general open areas, retail spaces, aisles and manufacturing areas. Certain airborne contaminants can diminish integrity of
acrylic. Refer to Acrylic Environmental Compatibility Chart on page 735 for suitable uses.

Hi-Tek®

Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
A20

Optics – Injection-molded virgin acrylic lens, fully fluted anodized aluminum reflector. Hinge
and lens retainer latches facilitate tool-less removal for maintenance and cleaning. Totally enclosed, gasketed refractor and reflector inhibit

the entrance of ambient contaminants. All distribution patterns are widespread.
Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse-rated.
Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed -30°C to 40°C ambient
operation and damp locations (High Ambient HA
option for 55°C). UL wet location available.
Meets UL lamp rupture containment specifications.

A26

Example: TX 400M A26 277 SCWA HOCS

Ordering Information

Series

LITHONIA INDOOR HID

TX

370

Wattage

Optical1

High pressure sodium, 20” diameter
50S
A20
70S
A20
100S
A20
150S
A20
200S
A20
250S
A20
High pressure sodium, 26” diameter
250S
A26
400S
A26
Metal halide, 20” diamter
100M
A20
150M
A20
175M
A20
200M
A20
250M
A20
Metal halide, 26” diameter
250M
A26
320M
A26
350M
A26
400M
A26
450M
A26

Voltage
120
208 2,3
240 2,3,4
277
347
480 3
TB5
TBV6

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.
TX A20
Overall height: 21-3/8 (54.3)
Reflector height: 14-1/2 (36.2)
Diameter: 20-3/4 (52.7)

TX A26
Overall height: 24-3/8 (61.9)
Reflector height: 17-1/16 (43.3)
Diameter: 27-1/2 (69.9)

www.lithonia.com, keywords: TX-A20 and TX-A26

Options/Accessories
See pages 386-397. HID lamps are available with luminaires. Consult factory.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
50 (TXL A20)
HX-HPF
11 5
70 (TXL A20)
HX-HPF
12 5
100 (TXL A20)
HX-HPF
14 6
150 (TXL A20)
HX-HPF
15 7
200 (TXL A20)
CWA
17 8
250 (TXL A20)
CWA
21 9
250 (TXL A26)
CWA
29 13
400 (TXL A26)
CWA
37 17
Metal halide (med (100) mog/clear)
100 (TXL A20)
CWA
16 7
175 (TXL A20)
CWA
17 8
250 (TXL A20)
CWA
20 9
250 (TXL A26)
CWA
25 11
400 (TXL A26)
CWA
32 15

S/mtg.
height
1.9
1.8
1.9
1.9
1.9
1.7
2.0
2.0
1.8
1.8
1.7
2.2
2.2

NOTES:
1 Replace A in optical nomenclature with P for polycarbonate lens.
2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
3 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
4 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
6 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W metal halide and high pressure sodium (CWA only).

PSG9

Premium Enclosed Aluminum Optical
For areas that require high efficiencies, high horizontal and vertical illumination and good glare
control at low mounting heights. Ideal for general open areas, retail spaces, aisles and manufacturing areas. Certain airborne contaminants can
diminish integrity of acrylic. Refer to Acrylic
Environmental Compatibility Chart on page
735 for suitable uses.
Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minmum of class H insulation.
Optics – Injection-molded virgin acrylic lens, fully fluted, anodized aluminum reflector; exclusive
spun-fluted anodized reflector. Hinge and lens
retainer latches facilitate tool-less removal for

maintenance and cleaning. Totally enclosed, gasketed refractor and reflector inhibit the entrance of ambient contaminants. All distribution
patterns are widespread.

TX A30
Hi-Tek®

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse-rated.

LLOW
OW BA
Y
BAY

Intended Use

Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.
Listings
UL Listed. CSA Certified. NOM Certified. UL Listed
-30°C to 40°C ambient operation and damp locations (High Ambient HA option for 55°C). UL wet
location available. Meets UL lamp rupture containment specifications.

A30

Example: TX 400M A30 TB SCWA

Ordering Information

Series

Wattage

Optical

Voltage

TX

High pressure sodium
250S
400S
Metal halide
175M
200M
250M
320M
350M
400M
450M

A301

120
208 2,3
2402,3,4
277
347
480 3
TB5
TBV6

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

PSG9

www.lithonia.com, keyword: TX-A30

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
250
CWA
26 12
400
CWA
31 14
Metal halide (mog/clear)
250
CWA
26 12
400
CWA
28 13

S/mtg.
height
2.0
2.0
2.1
2.1

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

TX A30
Overall height: 22-1/4 (56.5)
Reflector height: 15-1/4 (38.7)
Diameter: 30-3/4 (78.1)

LITHONIA INDOOR HID

NOTES:
1 Replace A in optical nomenclature with P for polycarbonte lens.
2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
3 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
4 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
6 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W metal halide and high pressure sodium (CWA only).

Options/Accessories
See pages 386-397. HID lamps are available with luminaires. Consult factory.

371

LOW BA
Y
BAY

Enclosed Aluminum Optical

TX A23

Intended Use
For areas that require vertical illumination and
glare control at low mounting heights. Ideal for
general open areas, retail spaces and aisles.
Certain airborne contaminants can diminish
integrity of acrylic. Refer to Acrylic Environmental Compatibility Chart on page 735 for
suitable uses
uses.

Hi-Tek®

Features
Housing – Rugged, heavy-duty, die-cast aluminum with white polyester powder finish. Electrical components horizontally opposed and heatsinked to ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.

Socket – Glazed porcelain, vertically oriented
socket with copper alloy, nickel-plated screw
shell and center contact. UL Listed 1500W, 600V,
4KV pulse rated.
Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. Meets UL lamp rupture containment specifications. UL Listed for damp locations. Ambient operation:-30° to 40°C (High Ambient HA option for 55°C). UL wet location available.

Optics – Injection-molded, virgin acrylic lens
and highly reflective, white polyester powder
painted reflector. UV stabilized. Hinge and lens
retainer latches facilitate tool-less removal for
maintenance and cleaning. Inhibits entrance of
outside contaminants.

A23

Example: TX 400M A23 TB SCWA

Ordering Information

Series

Wattage

Optical

TX

High pressure sodium
250S
400S
Metal halide
175M
200M
250M
320M
350M
400M
450M

A23 2

TXD1

Voltage
120
208 3,4
2403,4,5
277
347
480 3,4
TB6
TBV7

Options/Accessories

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast

See pages 386-397. HID lamps are available with luminaires.
Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

LITHONIA INDOOR HID

Express delivery products.

372

TXD1

TX A23
Overall height: 22-1/4 (56.5)
Reflector height: 15-1/4 (38.7)
Diameter: 23 (58.4)

Lamp/fixture
Standard
Wattage
ballast
High pressure sodium (mog/clear)
250
CWA
400
CWA
Metal halide (mog/clear)
250
CWA
400
CWA

data
Weight
lbs. kgs.

See page11 for details about LightQuick XD.
S/mtg.
height

23
29

10
13

1.6
1.6

21
25

10
11

1.7
1.7

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

www.lithonia.com, keyword: TX-A23

Description
TX 250M A23 TB
TX 400M A23 TB
NOTES:
1 TXD consists of TX housing and A23 optical assembly shipped in one carton.
Available with tapped ballast or 480V only. Available only in 250M, 320M and
400M.
2 Replace A in optical nomenclature with P for polycarbonte lens.
3 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
4 Requires CWIor MRBoption in Canada for high pressure sodium. Available for
70-400W only.
5 220V and 240V, 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
6 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
7 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W metal halide and high pressure sodium (CWA only).

PSG9

Enclosed Aluminum Optical
For areas that require vertical illumination and
glare control at low mounting heights. Ideal for
general open areas, retail spaces and aisles.
Steel ballast housing should be used in areas
with minimal airborne contaminants. Certain
airborne contaminants can diminish integrity of
acrylic. Refer to Acrylic Environmental Compatability Chart on page 735 for suitable uses.
Features
Housing – Steel housing with white polyester
powder coat finish. All electrical components
are positioned to assure unit will hang straight.
Housing is ventilated for optimal thermal performance.
Ballast – Electronic ballast is 100% factory tested. Ballast will operate pulse start lamps only
from 200-277V.

er latches facilitate tool-less removal for maintenance and cleaning. Inhibits entrance of outside
contaminants.

SX A23

Socket – Glazed porcelain, vertically oriented
socket with copper alloy, nickel-plated screw
shell and center contact. UL Listed 1500W, 600V,
4KV pulse rated.

Hi-Tek®

Installation – One-piece galvanized hook and
spring steel latch with cord and plug (SC3P) is
standard. Pendant splice box (PSB) with top entry for 3/4” conduit also available with mounting
options.
Listings
UL Listed to U.S. and Canadian safety standards. NOM Certified. Meets UL lamp rupture
containment specifications. UL Listed for
damp locations. Ambient operations: -30°C to
40°C (High Ambient HA option for 55°C).

Optics – Injection-molded, virgin acrylic lens and
highly reflective, white polyester powder painted reflector. UV stabilized. Hinge and lens retain-

A23

Example: SX 400M A23 TVOLT GEB PSB

Ordering Information

Series
SX

LOW BA
Y
BAY

Intended Use

Wattage

Optical

Voltage

Metal halide
320M
350M
400M

A23 1

208
240
277
TVOLT2

Ballast

Options/Accessories

Pulse Start H.I.D. Ballast/Lamp Systems

See pages 386-397. HID lamps are available with
luminaires. Consult factory.

Pulse start metal halide
GEB Electrionic ballast
See pages 384-385 for details.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
Metal halide (mog/clear)
400
GEB
12 5.5

S/mtg.
height
1.7

NOTES:
1 Replace A in optical nomenclature with P for polycarbonte lens. HID lamps are
available with luminaires. Consult factory.
2 Tri-volt electronic ballast capable of operating on any line voltage between 200V
and 277V at 50 or 60 Hz (available with GEB option only). Pendant splice box (PSB)
mounting required.

PSG9

www.lithonia.com, keyword: SX-A23

SX A23
Overall height: 23-1/2 (59.7)
Reflector height: 15-1/4 (38.7)
Diameter: 23 (58.4)

LITHONIA INDOOR HID

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

373

LOW BA
Y
BAY

Premium Enclosed NSF Certified Optical

TXF A30F
TXF PA25ALEF
Acrylume® and Hi-Tek®

Intended Use
For general area illumination of food processing
and hose-down areas requiring high efficiencies,
horizontal illumination, premium glare control,
ease of cleanability, compliance to FDA/USDA requirements and/or NSF splash-zone certification.
For more NSF information, see page 733. Certain
airborne contaminants can diminish integrity of
acrylic. Refer to Acrylic Environmental Compatibility Chart on page 735 for suitable uses.
Features

PA25ALEF

A30F

Housing – Fully gasketed, heavy-duty, die-cast
copper free (<0.4%) aluminum ballast housing.
Finish meets FDA CFR 21 175.300 for resinous
and polymeric coatings. Electrostatically applied
white polyester powder paint. Electical components heat-sinked and horizontally opposed. External hardware is stainless steel or corrosionresistant with no exposed threads.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.

TXF

Wattage
High pressure sodium
250S
400S
Metal halide
175M
200M
250M
320M
350M
400M
450M

Optical
PA25ALEF
A30F

Voltage
120
208 1,2
2401,2,4
277
347
480 2
TB3
TBV5

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA

LITHONIA INDOOR HID

See pages 384-385 for details.

374

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.

TXF A30F
Overall height: 22-1/4 (56.5)
Reflector height: 15-1/4 (38.7)
Diameter: 30-3/4 (78.1)

Installation – Pendant splice box threaded for ¾” conduit (standard). Other mounting options available.
Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for -30°C to 55° C ambient operation and wet locations. NSF International certified splash-zone and meets FDA/
USDA guidlines. Meets UL lamp rupture containment specifications. A30F is IP65 rated against
ingress of water and contaminants and is suitable for high-pressure hose-downs up to 1200
psi.

Example: TXF 400M A30F TB LLSCWA

Ordering Information

Series

Optics – PA25ALEF: Enclosed and gasketed, injection-molded, UV stabilized, virgin acrylic reflector
and flat lens. A30F: anodized aluminum and UV-stabilized virgin acrylic lens. Gasketed reflector and
lens inhibit entrance of contaminants.

TXF PA25ALEF
Overall height: 26-3/8 (66.9)
Reflector height: 15-3/8 (38)
Diameter: 25-3/4 (65.4)

www.lithonia.com, keywords: TXF-PA25ALEF and TXF-A30F

Options/Accessories
See pges 386-397. HID lamps are available
with luminaires. Consult factory.

Lamp/fixture data
Standard
Wattage
ballast
High pressure sodium (mog/clear)
250 (TXF PA25ALEF)
CWA
250 (TXF A30F)
CWA
400 (TXF PA25ALEF)
CWA
400 (TXF A30F)
CWA
Metal Halide (mog/clear)
250 (TXF PA25ALEF)
CWA
250 (TXF A30F)
CWA
400 (TXF PA25ALEF)
CWA
400 (TXF A30F)
CWA

Weight
lbs. kgs.

S/mtg.
height

39
26
39
31

18
12
18
14

1.1
2.0
1.1
2.0

35
26
35
28

16
12
16
13

1.2
2.1
1.2
2.1

NOTES:
1 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W
only.
2 Requires CWI or MRB option in Canada for high pressure sodium. available for
70-400W only.
3 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
4 220V and 240V 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
5 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400 W, 1000W metal halide and high pressure sodium (CWA only).

PSG9

Enclosed Prismatic Acrylic Optical
For areas that require high vertical illumination
and wide spacings. Ideal for aisles, service areas
and parking garages. Certain airborne contaminants can diminish integrity of acrylic. Refer to
Acrylic Environmental Compatibility Chart on
page 735 for suitable uses.
Features
Housing – Rugged, heavy-duty, die-cast aluminum
with white polyester powder finish. Electrical components horizontally opposed and heat-sinked to
ballast housing for cooler operation.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – 12” diameter (A125, A121): Anodized aluminum reflector with one-piece injection-molded
acrylic or polycarbonate refractor and bottom enclosure. 16” diameter (A165, A162): High efficiency,
optical-quality, white polyester powder finish with
one-piece injection-molded acrylic or polycarbon-

ate refractor and bottom enclosure. Consult factory. Type I and II: Asymetrical long and narrow distribution. Type V: Symetrical circular distribution. OB
optics are open bottom.
Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy, nickelplated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated.

TX A121/A125
TX A162/A165

LOW BA
Y
BAY

Intended Use

Hi-Tek®

Installation – Pendant splice box threaded for
¾” conduit (standard). Other mounting options
available.
Listings
UL Listed to U.S. and Canadian safety standards.
NOM Certified. UL Listed for damp locations and 30°C to 40°C ambient operation (High Ambient HA
option for 55°C). UL wet location available, closed
bottom only. Meets UL lamp rupture containment
specifications (except OB open bottom optics).
A125

A165

Example: TX 150S A125 277 HC3P

Ordering Information

Series
TX

Optical3 (select one)

High pressure sodium, 12” diameter
Type V
Type I
70S
A12
A121
100S
A125
A121
150S
A125
A121
200S2
A125OB
A121OB
250S2
A125OB
A121OB
Metal halide, 12” diameter
Type V
Type I
100M
A125
A121
High pressure sodium, 16” diameter
Type V
Type II
200S
A165
A162
250S
A165
A162
400S2
A165OB
A162OB
Metal halide protected, 16” diameter1
Type V
Type II
320MP 2
A165OB
A162OB
350MP 2
A165OB
A162OB
400MP 2
A165OB
A162OB
450MP 2
A165OB
A162OB
Metal halide, 16” diameter
Type V
Type II
100M
A165
A162
150M
A165
A162
175M
A165
A162
200M
A165
A162
250M
A165
A162
400M 2
A165OB
A162OB

Voltage
120
208 4,5
2404,5,6
277
347
480 4,5
TB7
TBV8

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
MRB Magnetic regulator ballast
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
RLB Regulated lag ballast
SCWI Isolated SCWA
See pages 384-385 for details.

NOTES:
1 See page 385 for details on protected sockets.
2 Open bottom only.
3 Change A in nomenclature to P. Example: P125. All except open-bottom fixtures meet UL lamp rupture containment specifications.
4 Requires CWI option in Canada for metal halide. Available for 175-400W only.
Not available for 250W in 480V.
5 Requires CWI or MRB option in Canada for high pressure sodium. Available for
70-400W only.
6 220V and 240V 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
7 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
8 Optional five-tap ballast (120V, 208V, 240V, 277V, 480V). Available for 250W,
400W, 1000W metal halide and high pressure sodium (CWA only).

www.lithonia.com, keywords: TX-A121, TX-A125, TX-A162
and TX-A165

Options/Accessories
See pages 386-397. HID lamps are available
with luminaires. Consult factory.

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear), 12”, Type V
70
HX-HPF
15 7
100
HX-HPF
17 8
150
HX-HPF
17 8
200
CWA
20 9
250
CWA
23 10
High pressure sodium (mog/clear), 16”, Type V
200
CWA
22 10
250
CWA
25 11
400
CWA
36 16
Metal halide (med/clear), 12", Type V
100
CWA
15 7
Metal halide (med (100) mog/clear), 16", Type V
100
CWA
20 10
175
CWA
21 10
250
CWA
23 10
400
CWA
30 14

S/mtg.
height
1.8
1.8
1.8
2.7
2.6
1.9
2.6
1.8
1.8
1.3
1.3
1.3
1.8

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise
noted.
TX A125/A121
Overall height: 17 (43.2)
Reflector height: 10 (25.4)
Diameter: 12-1/4 (31.1)

TX A165/A162
Overall height: 19-5/8 (49.8)
Reflector height: 13-5/8 (34.6)
Diameter: 16-3/4 (42.6)

LITHONIA INDOOR HID

PSG9

Wattage

375

LOW BA
Y
BAY

Enclosed Prismatic Acrylic Optical

TGL
TGR

Intended Use
For areas that require optimum vertical illumination with glare control at low mounting
heights. Ideal for parking garages, greenhouses,
garden centers and low-profile industrial aisles.
Certain airborne contaminants can diminish
integrity of acrylic. Refer to Acrylic Environmental Compatibility Chart on page 735 for
suitable uses
uses.
Features
Housing – Rugged, heavy, die-cast aluminum
housing. Standard finish is natural aluminum
polyester powder finish.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.

TGL

Induction lighting: High Frequency Generator/
Ballast - Supplies high-frequency current to the
lamp to initiate and maintain a gas discharge for
a rated 100,000 hours of life.

(A162), TGR Type V (A125), and Type 1 (A121) distributions are available. Polycarbonate refractor
available.
Socket – Glazed porcelain, vertically oriented
mogul-base socket with copper alloy, nickelplated screw shell and center contact. Mediumbase (100M only): UL Listed 660W, 600V, 4KV
pulse rated.
Discharge Vessel/Lamp – Glass bulb that contains
a mixture of low-pressure mercury vapor and inert buffer gas. The wall of the lamp is coated with
a fluorescent powder that produces light.
Listings
TGL: UL Listed to US and Canadian safety standards. NOM Certified. TGR: UL Listed and CSA Certified. NOM Certified. UL Listed for damp locations. Ambient operation: -30°C to 40°C (250M);
-40°C to 25°C (85IL). UL wet location optional.

Optics – One-piece, injection-molded, 100% virgin acrylic refractor. TGL Type V (A165), Type II

TGR

Example: TGL 175M A165 TB PM

Ordering Information

Series
High pressure sodium
TGL

TGR

Metal halide
TGL

TGR

LITHONIA INDOOR HID

Induction
TGL

376

Optical2

Wattage
70S
100S
150S
70S
100S
150S

Type V
A165
A165
A165
A125
A125
A125

Type II
A162
A162
A162
A121
A121
A121

100M
175M
200M
250M 1
100M
175M

A165
A165
A165
A165
A125
A125

A162
A162
A162
A162
A121
A121

85IL
55IL

A165
A165

A162
A162

Voltage
120
208 3,4
240 4,5
277
347
480 4
TB6

Options/Accessories

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast

See pages 386-397. HID lamps are available with luminaires.
Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
See pages 384-385 for details.

NOTES:
1 Not available with SCWA.
2 Polycarbonate lens: Replace A in optical nomenclature with P for
polycarbonte lens.
3 Requires CWI option in Canada. Only available in 250M.
4 Requires CWI or MRB option in Canada for high pressure sodium.
Available for 70-150W.
5 220V and 240V, 50Hz and 60Hz ballasts available for use with U.S.
metal halide and high pressure sodium lamps.
6 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V,
347V in Canada).

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
TGL Type V
High pressure sodium (mog/clear)
70
HX-HPF
21 9
100
HX-HPF
23 10
150
HX-HPF
23 10
Metal halide [med(100)/mog(175–250)/clear]
100
CWA
20 9
175
CWA
23 10
250
CWA
26 12
TGR Type V
High pressure sodium (mog/clear)
70
HX-HPF
11 5
100
HX-HPF
13 6
150
HX-HPF
14 6
Metal halide [med(100)/mog(175)/clear]
100
CWA
13 6
175
CWA
14 6

S/mtg.
height

2.3
2.3
2.3
1.2
1.7
1.7

1.8
1.7
1.8
1.7
1.8

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

Ambient Parameters
TGL
Overall height: 13-3/8 (34)
Diameter: 16-3/4 (42.5)

TGR
Overall height: 11-1/4 (28.6)
Diameter: 12-1/2 (31.8)

TGL PM
Overall height: 15-1/2 (39.4)
Diameter: 16-3/4 (42.5)

TGR PM
Overall height: 13-3/8 (34)
Diameter: 12-1/2 (31.8)

TGR
TGL 100-175M
TGL 250M
TGL 70-150S
TGL 55-85IL

www.lithonia.com,keyword: TGL-TGR

-40°C to 25°C
(-22° to 77°F)

-30° to 40°C
(-22° to 104°F)
■
■

■

-30° to 55°C
(-22° to 131°F)
■
■
■ = COMPATABILITY

PSG9

Shroud with Lens
For areas that require low mounting heights.
Used in applications including parking garages,
stairwells, entrances or aisles.
Features
Housing – Rugged, heavy-duty aluminum housing. Standard finish is dark bronze polyester powder finish.
Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Optics – One-piece, spun-aluminum, anodized
reflector provides widespread distribution.
High-impact, shock-resistant, tempered glass
lens is fully gasketed to seal out contaminants.

TG

660W, 600V, 4KV pulse rated; mogul-base: UL
Listed 1500W, 600V, 4KV pulse rated.
Installation – Quick-mount attachment plate
mounts to 4” square or octagonal J-box. Plate is
hinged to fixture housing during installation.
Fixture is then twist-locked into place and secured in a tamperproof installation. Internal trigger mechanism releases fixture from J-box. Factory-installed pendant mount option (PSB)
available.

LOW BA
Y
BAY

Intended Use

Listings
UL Listed. CSA Certified. NOM Certified. UL Listed
for damp locations.

Socket – Glazed porcelain, vertically oriented
socket with copper alloy, nickel-plated screw
shell and center contact. Medium-base: UL Listed
TG

Example: TG 175M E13 TB PSB

Ordering Information

Series
TG

Wattage
High pressure sodium,
wide distribution
70S
100S
150S
200S
Metal halide
100M 1
175M
200M
250M

Optical

Voltage

E13

208 1
240 1,2
277
347
480 1
TB3

Ballast

Options/Accessories
See pages 386-397. HID lamps are available with
luminaires. Consult factory.

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated
Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage autotransformer
LLSCWA Low loss SCWA
See pages 384-385 for details.

Ambient Parameters

-30° to 25°C
(-22° to 77°F)

-30° to 40°C
(-22° to 104°F)

■
■

■
■
■ = COMPATABILITY

Lamp/fixture data
Standard
Weight
Wattage
ballast
lbs. kgs.
High pressure sodium (mog/clear)
70
100
150
200
Metal halide
100
175
250

PSG9

HX-HPF
13
HX-HPF
15
HX-HPF
16
CWA
19
(med/mog(175–250)/clear)
CWA
15
CWA
17
CWA
19

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

S/mtg.
height

6
7
7
9

1.8
2.2
2.5
1.7

7
8
9

2.2
2.2
2.2

TG
Overall height: 13-5/8 (34.6)
Diameter: 13-1/2 (34.3)

NOTES:
1 Not available in Canada.
2 220V and 240V 50 Hz and 60 Hz ballasts available for use with U.S. metal halide
and high pressure sodium lamps.
3 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).

www.lithonia.com,keyword: TG

TG (PSB)
Overall height: 15 (38.1)
Diameter: 13-1/2 (34.3)

LITHONIA INDOOR HID

TG 175M
TG 250M
TG 70-150S
TG 200S

-30° to 55°C
(-22° to 131°F)

377

GENERAL AREA LIGHTING

2’ x 2’ Recessed Squares

GPV

Intended Use

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Thermally activated insulation detector included.

Use in recessed hard ceiling and T-bar applications that require optimum horizontal illumination with superior brightness control and lamp
shielding. Ideal for open office, retail and commercial areas.

Parabolic Louvers

Socket – Mogul-based porcelain socket with copper alloy, nickel-plated screw shell and center
contact. UL Listed 1500W, 600V, 4KV pulse rated.

Features

16 cells

Installation – 2' nominal aperture. Power door
contains all electrical components. Pre-wired 7',
16-guage leads and 90° connector, no flex. Power door swings down for easy access or can be removed for servicing. Overlapping flange kit (GFKIT) available for non-T-Bar applications.

Optics – Specular clear parabolic 16-cell or 9cell, 4” deep aluminum louvers float in the middle of a black reveal with tempered glass overlay.
Louver door attached with T-hinges and spring
loaded latches for positive retention. Coated
lamps provide optimum performance.

Listings

Housing – 20-gauge steel housing with high reflectance, white polyester paint.

9 cells

UL Listed. CSA Certified. UL Listed for recessed
mounting and damp locations.

Ordering Information

Example:

Series

Wattage1

Specular louver

Voltage

Ballast

Options/Accessories

GPV Vertical lamp

Metal halide
175M
200M 2
250M
320M 2
350M 2
400M

16 cells
16AGL Specular clear with glass overlay
9 cells
9AGL Specular clear with glass overlay

120
208
240
277
347
TB3

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated

See page 379. HID lamps
are available with
luminaires. Consult
factory.

NOTES:
1 Mogul-base lamps required. Coated lamps recommended.
2 Available only when ordered with pulse start ballast.
3 Multi-tap ballast. US: 120V, 208V, 240V, 277V; Canada: 120V,277V, 347V.

STANDARD PACKAGING
To order, use single master catalog number. Example:
(21)
GPV 175M 9AGL 120
Housings and door assemblies ship separately in unit cartons.
Example above ships as:
(Qty 21)
GPV 175M GL 120 HSG (21cartonsof1housing)
(Qty 21)
GP 9A U (21 cartons of 1 door assembly)

Round Reflector

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
SCWI Isolated SCWA
See pages 384-385 for details.

mal brightness. White painted steel door assembly with clear tempered glass lens, retention
hinge and latch. Coated lamps provide optimum
performance.

Intended Use
Use in recessed hard ceiling and T-bar applications that require downlight illumination with
brightness control. Ideal for recreation facilities,
retail and other commercial areas.

GS

Socket – Glazed porcelain, vertically oriented,
mogul-base socket with copper alloy nickel-plated screw shell and center contact. UL Listed
1500W, 600V, 4KV pulse rated.

Features
Housing – Square steel pan finished in polyester
matte white powder paint.

Installation – Electrical components factory assembled to the pan and ready to lay in a 2'x2' grid
ceiling. Pre-wired 7', 16-gauge leads and 90°
connector, no flex.

LITHONIA INDOOR HID

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Thermally activated insulation detector included.

378

GPV 400M 9AGL 120

Listings

Optics – One-piece, semi-specular, spun aluminum reflector. Exclusive design with extended
shielding provides wide distribution with mini-

UL Listed. CSA Certified. UL Listed for recessed
mounting and damp locations.

Ordering Information

Example:

Series

Wattage1

Voltage

GS Vertical lamp, flat
pan, round reflector

Metal halide
175M
200M 2
250M
320M 2
350M 2
400M

120
208
240
277
347
TB3

NOTES:
1 Mogul-base lamps required. Coated
lamps recommended.
2 Available only when ordered with
pulse start ballast.
3 Multi-tap ballast. US: 120V, 208V,
240V, 277V; Canada: 120V,277V, 347V.

Ballast
Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant Wattage Isolated

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
SCWI Isolated SCWA

GS 175M 120
Options/accessories
See page 379. HID lamps
are available with
luminaires. Consult
factory.

See pages 384-385 for details.

www.lithonia.com, keyword: G

PSG9

2' x 2' Recessed Squares
Use in hard ceiling and T-bar applications with
low mounting heights that require optimum
horizontal illumination with brightness control.
Ideal for office, retail and commercial areas. Prismatic tempered glass lens with polycarbonate
underlay suitable for gymnasiums and racquetball courts.
Features
Optics – Anodized aluminum top reflector. Door
assemblies available with choice of prismatic
tempered glass, prismatic acrylic and tempered
prismatic glass with polycarbonate underlay.
Door attaches to housing with T-hinges and two
opposing cam latches for positive retention. G3V
series rough service door assembly secured by
additional four screws.

G2V
G3V

Ballast – 100% factory tested. High power factor
ballast with a minimum of class H insulation.
Thermally activated insulation detector included.
Socket – Mogul-based porcelain socket with copper alloy, nickel-plated screw shell and center
contact. UL Listed 1500W, 600V, 4KV pulse rated.
Installation – 2x2 lay-in housing design with
power door containing all electrical components. Pre-wired 7', 16-guage leads and 90° connector, no flex. G2V power door swings down for
easy access or can be removed for servicing. G3V
uses four Philips flathead retaining screws for
positive retention. Overlapping flange kit available (GFKIT) for non-T-Bar applications.

Prismatic Lenses

GENERAL AREA LIGHTING

Intended Use

Listings
UL Listed. CSA Certified. UL Listed for recessed
mounting and damp locations.

Housing – 20-gauge steel housing with high reflectance, white polyester paint.

Ordering Information

Series

Wattage1

G2V
G3V

Metal halide
175M
200M 2
250M
320M 2
350M 2
400M

Example:

Door frame
RW Regressed white aluminum
FW Flush white aluminum
FS Flush white steel3

RW
FW
FS

Door frames
G2V
G3V
Option
Option
Option
Standard
Standard
N/A

NOTES:
1 Mogul-base lamps required. Coated lamps recommended.
2 Available only when ordered with pulse start ballast.
3 Available with G2V luminaires only.
4 Available with G3V luminaires only.
5 Multi-tap ballast. US: 120V, 208V, 240V, 277V; Canada: 120V,277V, 347V.

G2V 400M FS T73 120

Shielding

Voltage

Ballast

Options/Accessories

T73 Tempered prismatic
glass lens
84YGL Holophane #8224Y
acrylic lens with
tempered glass
overlay
A12GL Prismatic acrylic lens
with tempered glass
overlay
T73/PCL Tempered prismatic
glass lens with
polycarbonate
underlay4

120
208
240
277
347
TB5

Metal halide and high pressure sodium
(blank) Standard magnetic ballast
CWI Constant wattage isolated

See below. HID lamps are
available with luminaires.
Consult factory.

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
LLRPSL Linear reactor pulse start
SCWA Super constant wattage
autotransformer
LLSCWA Low loss SCWA
SCWI Isolated SCWA
See pages 384-385 for details.

G Series Options
Series

Description
Attached

NOTES:
1
2

PSG9

White flange trim, baked-on satin enamel finish
Quick-Flex®
Single fuse,120/277/347V only, N/A multi-tap ballast
Double fuse, 280/240/480V only, N/A multi-tap ballast
Quartz restrike system (D.C. base)
Quartz restrike system with time delay
Emergency circuit (D.C. base)
Top access
Prewire with 14-gauge THHN leads, 6' flex
Super CWA pulse start ballast
Linear reactor pulse start ballast
KiloWatch® 120V control relay, 50% wattage reduction
KiloWatch® 277V control relay, 50% wattage reduction
KiloWatch® 120V control relay, 50% light (lumen) reduction
KiloWatch® 277V control relay, 50% light (lumen) reduction
Plaster frame
Earthquake clips
Wireguard (for grid ceiling)
Flange kit
Flange kit

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Available flange trim units G2V and G3V only.
Available T-bar ceiling units only.

www.lithonia.com , keyword G

G2V

G3V

STD
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
2
2

STD
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
2
2

X

X

GPV

GS

X
X
X
X
X
X
X
X
X
X
X
X
X

X
X
X
X
X
X

2
2
X

2
2

X
X
X
X
X
X
X

LITHONIA INDOOR HID

TRW
QFC
SF
DF
QRS
QRSTD
EC
TA
PWS1436
SCWA
LLRPSL
KW1
KW4
KW150
KW450
TCPF
HTC
WG12
GPFKIT
GFKIT

Ships
Separately

379

DOCK LIGHTS

Dock and Trailer Lighting

DSA
FSSA

cent is polycarbonate and metal for 300W incandescent. Both include metal wireguard standard.
Polycarbonate 50W high pressure sodium lamp
head with reflective coating, integral ballast and
flush polycarbonate guard. Optional SED acrylic
lens suitable for use in food service dock areas.

long service without sagging or bending. Hinged
ends reinforced internally with aluminum inserts.
Corrosion-resistant hardware. Nuts are locking
and exposed threads are plastic capped. Arm and
strut ends feature injection-molded end caps.

Intended Use
Ideal for illuminating the interior of tractor
trailers during initial inspection, loading or unloading.
Features
Construction – Arms and struts constructed of
heavy-duty 1-½” cross-section, 14-gauge square
steel tubing. Reinforcement mounting brackets
provide maximum support of arm and head for

Finish – Safety-yellow polyester powder paint is
standard on arm, strut and metal lamp head.
Polycarbonate lamp heads colored safety yellow.

Installation – Arm and strut-mounting bracket
included. Arm assembly attaches to wall mounting bracket with single bolt. Lamp head attaches
with a single bolt to arm and is powered by a
NEMA plug and receptacle assembly in arm.
Heavy-duty wall bracket (HDWB) recommended
for fan/light combinations.

Electrical System: 120V only. Provided with threeprong plug and 8’ cord. Lamp head includes on/off
switch and porcelain medium-base socket with
copper alloy screw shell and center contact. Electrical cord lengths secured via grommets. high
pressure sodium models feature reactor type ballasts.

Listings
Listings – UL Listed to U.S. and Canadian safety
standards.

Optical System - Lamp head for 150W incandes-

DSA 150I

DSA ADJ 150I

FSSA ADJ 300I

Example: DSA40 ADJ 50S LPI

Ordering Information

Series
DSA

LITHONIA INDOOR HID

FSSA

380

Double-strut arm

Folding single-strut arm

Length
24

24”

40

40”

60

60”

90

90”

114

114”

40

40”

60

60”

NOTES:
1 Required for FSSA. Optional for DSA. Not available with DSA24, DSA114.
2 Vacuum metalized polycarbonate lamp head. 90" maximum length.
3 Available for 50S high pressure sodium only.
4 Heavy-duty wall bracket (HDWB) recommended. For fan and DSA arm
without lamp head, leave "Lamp" field blank.
5 Standard in 50S models. Not available for incandescent.

Knuckle
ADJ Adjustable knuckle joint

150I
300I
50S

DSA ADJ
Lamp head height: 7-7/8 to 8-3/4
(20.0 to 22.2)
Arm length: 40 to 96-1/4
(101.6to244.5)

Options

150W incandescent polycarbonate lamp
head with wireguard
300W incandescent metal lamp head with
wireguard
50W high pressure sodium polycarbonate
lamp head with polycarbonate guard2

300W incandescent

150W incandescent

Drawings are for dimensional detail only and may not represent actual mechanical
configuration. Dimensions are shown in inches (centimeters) unless otherwise noted.

DSA
Lamp head height: 7-7/8 to 8-3/4
(20.0 to 22.2)
Arm length: 26 to 95-1/4
(66.0 to 23.5)

Lamp
1

Accessories
DLMAG KIT

50W high pressure sodium
FSSA ADJ
Lamp head height: 7-7/8 to 8-3/4
(20.0 to 22.2)
Arm length: 47-3/4 to 96-1/4 (121.3 to
244.5)

FAN
HDWB
MLH
PLHI
PLHS
MLHWG6
PLHWG8
PLHPG
SED

www.lithonia.com, keywords: DSA and FSSA

SED
FAN
LPI

Special environment diffuser
(acrylic lens)3
3-speed fan4
Lamp included5

(Order separately)
Portable magnetic mounting kit for lamp heads.
Includes magnet, 6’ cord adaptor and hardware.
3-speed fan.4
Heavy-duty wall bracket.
300W incandescent metal lamp head with wireguard.
150W incandescent polycarbonate lamp head with
wireguard.
50W high pressure sodium polycarbonate lamp head
with polycarbonate guard.2
Replacement wireguard for 300W incandescent metal
lamp head.
Replacement wireguard for 150W incandescent
polycarbonate lamp head.
Replacement polycarbonate guard for 50W highpressure sodium polycarbonate lamp head.
Special environment diffuser (acrylic lens). 3

PSG9

Dual-Level Lighting with Integral Sensor System
The KiloWatch® II Integral Sensor System provides individual luminaire dual-level lighting
control for maximum energy savings and flexibility. Each luminaire contains an integral sensor
that mounts directly to the reflector. Application
opportunities include warehouses or select storage areas within manufacturing facilities.

TH/TX Series

KiloWatch® II

KW1S – Reduces wattage by 50%. (Light output
reduces by 70-80%.) Luminaire supplied with
motion sensor control and sensor mounting
bracket.
KW1S LT – Reduces wattage by 50%. (Light output reduces by 70-80%.) Luminaire supplied
with motion sensor control for low temperature
and sensor mounting bracket.

Features
Integral passive infrared motion sensor mounts
to the reflector and connects to the ballast housing with flexible metal conduit to control one
luminaire based on occupancy. Sensor detects
moving temperature differentials against background radiation. When motion is detected, luminaire is switched to high mode for 1.25 to 20
minutes (field adjustable) after motion no longer is detected. Sensor includes timing circuit for
automatic high mode start up of lamp for 20 minutes. A self-timing, 100-hour high-mode burn
function is field-activated for initial operation of
a new lamp.

HID CONTROL SYSTEM

desired option must be designated in the luminaire catalog number Options field.

Intended Use

SH/SX/SPG Series
ISM - Reduces wattage by 50%. (Light output reduces by 70-80%.) Luminaires supplied with motion sensor control and sensor mounting bracket. For GEB electronic ballast only.
Listings
UL Listed to U.S. and Canadian safety standards.
Not for use with dual wattage rated lamps. Lamp
manufacturer requires 100 hours high-mode
burn-in of new lamps prior to low-mode operation and 15 to 20 minutes of high-mode operation thereafter upon start-up.

Sensor is designed for use in indoor applications
with 15’ to 45’ mounting heights. Sensor provides 360° of coverage within the luminaire’s
lighting distribution. Standard operating temperature range from 14°F to 131°F (-10°C to
55°C). Low temperature option (LT) range from 40°F to 131°F (-40°C to 55°C).
KiloWatch II options listed below only are available with CWA/SCWA ballast configurations. The

Example: TH 400M PA22 120 KW1S

Ordering Information

Series
TE
TH
TX

Wattage
High pressure sodium
150S
250S
400S
1000S
Metal halide protected1
175MP
200MP
250MP
320MP
350MP
400MP
450MP
1000MP

E17
E22
A15
A16
A17
A22
A14
A26
A30
A23
A20

Ballast

Voltage

Optical
Metal halide
175M
200M
250M
320M
350M
400M
450M
1000M

A125
A165
PA16
PA22
PA22C
PA22SP
PA25ALE
PA25D
PA22GLE
PA22N

120
208
240
277
347
480

(blank)

CWA

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
SCWA Super constant wattage
autotransformer
See pages 384-385 for details.

Accessories

Options
KW1S2
KW1S LT2
SF
DF
QRS
QRSTD
EC
GL

TOB
T73
CR
CRT
TEF
TR
SCWA
RC3NP

NOTES:
1 See page 385 for details on protected sockets.
2 50% power.

DCY
DHX
DSQ
FWG
GFWG
HC3P
HKF
HKM

LCPP
LC3P
HC3P
HOCS
HOCU
LOCS
LOCU
CF

HKMG
LC3P
LGG
LPF
LPM
LPMG
PPH
TPH
SCK

SCK48
SCK108
SMB18
SMB24
TMB30
TMB48
WG
WGG

SENSOR COVERAGE CHART
0

10
15

Series

Wattage

Optical

Voltage

SH
SX
SPG

Metal halide protected1
320MP
350MP
400MP
Metal halide
320M
350M

A15
A16
A16GL
A23
PA22
PA22N
PA22SP
PG15

208
240
277
TVOLT

PSG9

Ballast
Pulse start metal halide
GEB Electronic ballast

Options/Accessories
ISM2
SF
DF
EL
QRSTD

OCS
HA
PSB
SC3P
WG
See pages 386-397
for details.

NOTES:
1 See page 385 for details on protected sockets.
2 50% power.

www.lithonia.com, keyword: KW

20
25
30
35
40
45
30

20

10

0

10

20

30

LITHONIA INDOOR HID

5

381

HID CONTROL SYSTEM

Dual-Level Lighting

®

KiloWatch
KWIR
KWTD

Intended Use
KiloWatch® dual-level HID luminaire option provides capability to switch ballast between high
mode and low mode operation. Choose from
100% to 50% power operation or 100% to 50%
lumen output operation. Luminaires must be
combined with motion sensors, photocells and/
or control transformers for complete system.
Ideal for energy reduction or light level control
in warehouses, storage areas, parking garages,
shipping docks and gymnasiums.
Features – Components
KWTD – Time delay control. Solid-state, digital timing circuit automatically provides high mode startup of each lamp for 15 minutes, guaranteeing lamp
stabilization. For 120V AC manually switched or
120V AC photocell (KWPC) applications.

KWTXTD

KWTXTD – Time delay control voltage transform-

er. Provides 120V AC control circuit power for
208/240/277/347/480V AC applications controlled by photocells or manual switching*. Includes solid-state, digital timing circuit for automatic high mode start-up of each lamp for 15
minutes, guaranteeing lamp stabilization. One
KWTXTD required for each on/off control zone of
up to 30 fixtures.
KWTX – Control voltage transformer. Provides
120V AC control circuit power for 208/240/347/
480V AC applications in conjunction with KWIR
motion sensors. High mode start-up of each
lamp for 20 minutes performed by KWIR sensors.
One KWTX required for each on/off control zone
of up to 30 fixtures.
KWIR – Passive infrared motion sensor. Switches
120V or 277V control relays in each lighting fixture based on occupancy. Sensor detects moving
temperature differentials against background

Manual Controls
shipped separately
System for 208/240/277/347/480V AC (one component)

System for 120V AC (one component)
KWTD

KWTXTD

Time delay control, manually switched. Automatic
timer keeps fixtures in high mode for 15 minutes
after start-up. 1

Control voltage transformer with time
delay. Steps supply voltage down for 120V
control. Automatic timer keeps fixture in
high mode for 15 minutes after start-up.1

Must add KW1 or KW150 to fixture description – 120V control.
Must add KW1 or KW150 to fixture description – 120V
control.

NOTES:
1 Manual control switches and wall boxes by others.

Motion Sensor Controls
shipped separately
System for 120/277V AC (one component)

System for 208/240/347/480V AC
(two components)
KWIR Motion sensor2,3
KWIR LT Motion sensor, low
temperature2,3
KWIR WA Motion sensor, wide
angle2,3
KWTX Control voltage
transformer; steps
supply voltage down
for 120V control

KWIR Motion sensor2,3
KWIR LT Motion sensor, low temperature (-30°)2,3
KWIR WA Motion sensor, wide angle2,3

LITHONIA INDOOR HID

Must add KW1 or KW150 to fixture description – 120V control.
Must add KW4 or KW450 to fixture description – 277V control.

382

NOTES:
2 Consult factory when using with Reloc® wiring.
3 Sensors have automatic timer to keep fixture in high mode for 20 minutes after
start-up.

KWIR

KWTX

Photocell Controls

System for 208/240/277/347/480V AC
(two components)

shipped separately
System for 120 AC (two components)
KWPC
KWTD

KWPC

Must add KW1 or KW150 to fixture
description – 120V control.

KWPC
KWTXTD

Photocell
Time delay control; automatic timer keeps fixture
in high mode for 15 minutes after start-up

Must add KW1 or KW150 to fixture description – 120V control.

KWPC

KWTD

KWTXTD

www.lithonia.com, keyword: KW

Photocell
Control voltage
transformer with time
delay steps supply voltage
down for 120V control;
automatic timer keeps
fixture in high mode for
15 minutes after start-up

Must add KW1 or KW150 to fixture
description – 120V control.

PSG9

ambient illumination levels (field adjustable).
Features – Luminaires
KiloWatch options listed below only are available with CWA/SCWA ballast configurations. The
desired option must be designated in the fixture
catalog number option field.
KW1 – Reduces wattage by 50% (light output reduces by 70-80%). Luminaire supplied with 120V
AC control components for use with all manually
switched*, KWPC photocell (120/208/240/277/
347/480V) or KWIR sensor (120/208/240/347/
480V) controlled systems.

KWIR WA – Same as KWIR sensor with wide angle
lens designed for use in indoor applications with
7’ to 8’ mounting heights where a short, wide
coverage pattern is desired (14°F to 160°F).

KW150 – Reduces light output by 50% (power
reduces by 30-40%). Luminaire supplied with
120V AC control components for use with all
manually switched*, KWPC photocell (120/208/
240/277/347/480V), or KWIR motion sensor
(120/208/240/347/480V) controlled systems.

KWIR LT– Passive Infrared Motion sensor. Same
as KWIR sensor designed for low temperature
operation (-40°F to 160°F).
KWPC –Photo-diode sensors. Sensors switch luminaires to low output based on predetermined

Ordering Information

Wattage

TE
TH
TPG
TPGE
TX
TGL
TGR

High pressure sodium
150S
250S
400S
1000S
Metal halide protected1
175MP
200MP
250MP
320MP
350MP
400MP
450MP
1000MP2
Metal halide
175M
200M
250M
320M
350M
400M
450M
1000M2

Voltage

Optical

Lamp manufacturers require 100 hours high
mode burn-in of new lamps prior to low mode
operation and 15 to 20 minutes of high mode operation thereafter upon start-up.
Not for use with dual wattage rated lamps.
* Manual switches and wall boxes by others.
Consult factory for field start-up service.

E17
E22
A15
A16
A17
A22
A14
A15
A26
A30
A23
A20
A30F
A125
A165
A1250B
A1650B

PA16
PA22
PA22C
PA22SP
PA25ALE
PA25D
PA22GLE
PA22N
PG16
PG16A
PG16GLE
PG16AGLE
PG21
PG21A
PG21GLE
PG21AGLE

120
208
240
277
347
480

(blank)

CWA

Pulse Start H.I.D. Ballast/Lamp Systems

Pulse start metal halide
SCWA Super constant
wattage
autotransformer

Sensors
KWIR
KWIR WA
KWIR LT
KWPC

Accessories

Options

Ballast
KW13
KW1504
KW45
KW4506
SF
DF
QRS
QRSTD
EC
GL
TOB

T73
CR
CRT
TEF
TR
LCKPP
LC3KP
HC3KP
HOCU7
LOCU7
CF

DCY
DHX
DSQ
FWG
GFWG
HC3KP
HKF
HKM
HKMG
LC3KP
LGG
LPF

LPM
LPMG
PPHKR
TPHKR
SCK
SCK48
SCK108
SMB18
SMB24
TMB30
TMB48
WG
WGG

NOTES:
1 See page 385 for details on projected sockets.
2 Not available on 1000W metal halide.
3 120V control relay, 50% wattage.
4 120V control relay, 50% light output.
5 277V control relay for 277V sensor applications only, 50% wattage.
6 277V control relay for 277V sensor applications only, 50% light output.
7 Consult factory when using Reloc® with KiloWatch®.

Controls

PSG9

Consult factory when using Reloc® with KiloWatch®.

Example: TH 400M A16 277 SCWA KW4

Ordering Information Example: KWIR

Control transformers
KWTX
KWTXTD

KW450 – Reduces light output by 50% (power
reduces by 30-40%). Luminaire supplied with
277V AC control components for use with KWIR
motion sensor-controlled systems.

KWIR Motion Detector Coverage
The sensor coverage shown is under ideal conditions.
Consult specification sheets for specific information.
The KWIR- WA mounted at 8’ has coverage zone of 120°
and distance at 40’.

www.lithonia.com, keyword: KW

LITHONIA INDOOR HID

Series

KW4 – Reduces wattage by 50% (light output reduces by 70-80%). Luminaire supplied with 277V
AC control components. For use with KWIR motion sensor controlled systems.

HID CONTROL SYSTEM

radiation. When motion is detected, lighting system is switched to high mode for one to 20 minutes (field adjustable) after motion no longer is
detected. Sensor includes timing circuit for automatic high mode start-up for 20 minutes. Sensor
is factory-preset at optimum performance angle
(43°) and can be field-adjusted. Sensor is designed
for use in indoor applications with 15’ to 35’
mounting heights where a long and narrow coverage pattern is desired (14°F to 160°F).

383

TECHNICAL INFO

Indoor HID Ballast Selection Guide
Metal Halide and High Pressure Sodium Ballasts

Pulse Start Metal Halide Ballasts

The characteristics of high pressure sodium, metal halide and mercury vapor high intensity discharge lamps require a ballast for controlling voltage
and current to operate the lamp at its proper wattage. Lamps that are not
operated within the optimal performance range will not produce proper
light output or experience full life. There are several ballast types to choose
that will provide proper control, but offer differing lamp wattage regulation, voltage dip tolerance, watts loss and cost.

Pulse start metal halide lamps provide higher lumens per watt and up to
15% better mean lumens than standard probe start lamps with an additional 15% gain in combination with electronic ballasts. These lamps have different operating characteristics that require different ballast designs with an
igniter to generate a starting pulse of 2,000 to 3,000 volts. Pulse start lamps
will start quicker and reach full brightness sooner during cold and hot starts.

CWA – Constant Wattage Autotransformer Ballast

SCWA – Super Constant Wattage Autotransformer
SCWI – SCWA Isolated Ballast

• Operates metal halide and high pressure sodium lamps
• 175W, 250W, 400W, 1000W metal halide and 100W, 200W, 250W, 400W,
1000W high pressure sodium lamps
• Input line voltage 120V, 208V, 240V, 277V, 347V, 480V
• Voltage dip tolerance; 30%
• Moderate watts loss
• Two coils with mid-size core
• Regulation ± 10% line voltage /±10% lamp wattage
• Crest factor 1.7 to 1.8
• Metal halide ballasts rated to operate mercury lamps; 175W, 250W,
400W, 1000W only
• Ideal for manufacturing and assembly type areas, general industrial, recreational and retail

• Operates 150W, 175W, 200W, 250W, 320W, 350W, 400W, 450W, 750W,
875W, 1000W pulse start metal halide lamps
• Input line voltage 120V, 208V, 240V, 277V, 347V, 480V
• SCWI isolated 2-coil system meets Canadian electrical code requirements 400W only – 120V, 208V, 240V only
• Voltage dip tolerance; 45%
• Moderate watts loss
• Regulation ± 10% line voltage /±10% lamp wattage
• Crest factor 1.6
• Ideal for manufacturing and assembly type areas, general industrial,
recreational and retail

LLRPSL – Low Loss Reactor Pulse Start Ballast
CWI – Constant Wattage Isolated Ballast
• Operates 250W, 400W, 1000W metal halide and 150W, 200W, 250W,
400W high pressure sodium lamps
• Isolated 2-coil system meets Canadian electrical code requirements for
208V and 240V applications in Canada
• Input line voltage 120V, 208V, 240V, 480V
• Voltage dip tolerance; 30%
• Moderate watts loss
• Regulation ± 10% line voltage /±10% lamp wattage
• Crest factor 1.7 to 1.8
• Adds increased safety during lamp replacement

• Operates 150W, 200W, 320W, 350W, 400W and 450W pulse start metal
halide lamps
• Input line voltage 277V only
• Voltage dip tolerance; 25%
• Low watts loss – energy saving ballast
• Single coil with smallest core design
• Regulation ± 5% line voltage /±12% lamp wattage
• Crest factor 1.4 to 1.5
• Starting current higher than operating
• Energy saver in areas where line dip tolerance is not critical; well suited for retail, light manufacturing, assembly type areas, institutional and
recreational

LITHONIA INDOOR HID

MRB - Magnetic Regulator Ballast

384

RLB – Regulated Lag Ballast

• Operates 70-400W high pressure sodium lamps
• Isolated 3-coil system meets Canadian electrical code requirements for
208V and 240V applications
• Input line voltage 120V, 240V, 277V, 480V
• Voltage dip tolerance; 50%
• High watts loss
• Excellent regulation ±10% line voltage /±3% lamp wattage
• Crest factor 1.5
• Ideal for heavy industrial application or areas with voltage dips and spikes

• Operates 175W, 250W, 400W, 450W pulse start metal halide lamps
(450W for 277V only)
• Input line voltage 120V, 208V, 240V, 277V, 347V, 480V
• Voltage dip tolerance; 50%
• High watts loss
• Excellent regulation ±10% line voltage /±3-7% lamp wattage
• Crest factor 1.5
• Ideal for heavy industrial application or areas with voltage dips and spikes

HX – High Reactance

GEB - Electronic Pulse Start Ballast

• Operates 70W, 100W, 150W metal halide and 50W, 70W, 100W, 150W
high pressure sodium
• Input line voltage 120V, 277V, 347V
• Low watts loss
• Regulation ± 5% line voltage /±12% lamp wattage
• Crest factor 1.5
• HPF high power factor 90%+ (standard)
• NPF normal power factor 50%+ (available)
• Starting current higher than operating

• Operates 320W, 350W, 400W pulse start metal halide lamps
• Auto-sensing input line voltage 200V to 277V 50/60Hz
• Voltage dip tolerance; 56%, automatically reduce lamp power 50% for
dip below 180V
• Low watts loss – energy-saving ballast
• 0-10VDC dimming control 50% to 100% lamp power
• Total harmonic distortion 15% maximum
• Excellent regulation ±10% line voltage /±0.5% lamp wattage
• Ideal for clean manufacturing and assembly type areas, institutional, recreational and retail

www.lithonia.com, keyword: Ballast

PSG9

Indoor HID Ballast Selection Guide
Conventional core and coil ballasts have an inherent hum from magnetic elements generated by the ballast circuit. The level of noise created by the luminaire depends on the ballast design, load characteristics, component
mounting in the housing, luminaire mounting and acoustical characteristics
of the application area. Encapsulating the ballast reduces the noise level created by the ballast for areas where sound levels are critical.

The GEB electronic pulse start ballast also provides a solution to eliminate ballast noise. The electronic ballast uses electronic circuitry to operate the lamps
and does not have a core and coil to create the hum of conventional ballasts.
The electronic ballast operates the lamp at a frequency that is beyond the audible range for silent operation .

■ = Option available

❐ = Standard

ENC – Encapsulated Ballast
• Provides quieter operation; not available in
all fixtures
• Class A sound rating up through 175W
• Class B for 250W and 400W

GEB – Electronic Pulse Start Ballast
• Provides silent operation
• High frequency operation beyond audible
range
• See GEB (page 384) for other operating
characteristics

Series
CWA 1
HX 1
CWI
MRB
LLRPSL
SCWA
RLB
GEB
ENC

SH

■

TECHNICAL INFO

Quieter Operation

SPG

■

SX

■

TE
❐
■
■
■
■
■

TH
❐
■
■
■
■
■
■

■

■

THD
❐

■2

Ballast selection table
TPG TPGE TX TXD
❐
❐
❐ ❐
■
■
■
■
■
■
■
■
■
■
■
■
■ ■2
■
■
■
■

■

■

TXF
❐
■
■
■
■
■
■

TG
❐
■
■

TGL
❐
■
■

■
■

■
■

■

■

TGR
■
❐

■

G
❐

GPV
❐

GS
❐

■

■

■

■
■

■
■

■
■

■

■

■

NOTES:
1 CWA is standard for 175W and above, and HX is standard for 150W and below for metal halide and high pressure sodium.
2 Not available on 250W.

Protected Sockets
Mogul Lamp Socket and Metal Halide Mogul Lamp Base Differences
The 2005 National Electric Code NFPA Code 70 Article 410.73 (F)(5) mandates indoor metal halide luminaires with open rated optics to have a
means that will permit the luminaire to operate only with an ANSI Type O
lamp. This article requires a protected lamp and socket for installations of
open rated metal halide luminaires. The differences between the lamp base
and socket types are explained below.
ANSI Type E – Type E metal halide lamps are enclosed rated and only suitable for enclosed luminaires that have a glass lens or plastic lens rated for
arc tube containment. These lamps have a standard mogul base design
with a broad contact point as shown. Typical for 175-1500W metal halide
lamps.

ANSI Type O – Type O metal halide lamps are open rated protected lamps for
use in open or enclosed luminaires. These lamps have "EX" style exclusionary
bases designed specifically for operation with pink protected sockets. The
mogul bases of these lamps have a narrow contact point designed for protected lamp sockets. Type O lamps most commonly have a cylindrical quartz barrier around the arc tube while some ceramic metal halide arc tubes are
wrapped with wire. Typical for 175-1500W metal halide lamps.
Standard Mogul Base Sockets – Standard sockets are constructed of porcelain and are white in color. The center contact tab will accept ANSI Type
E, S and O rated lamps. These sockets will continue to be used for metal halide HID lamps in indoor luminaires with enclosed optics.
Protected Mogul Base Sockets – Protected sockets are constructed of porcelain and are pink in color. The center contact tab is surrounded by a barrier that excludes ANSI Type E and S lamps by preventing contact between
the center pin on the lamp base and center tab on the lamp socket. Type O
rated lamps have a narrow center pin that fits in the barrier to make contact
with the center tab. These sockets will be required for indoor HID metal halide luminaires with open optics to comply with 2005 NEC.

Type O – "EX"
mogul base

Type E and S lamp
in white standard
mogul socket

PSG9

Type E and S
mogul base

Type O lamp in
white standard
mogul socket

www.lithonia.com, keyword: Protected Socket

Type O lamp in
pink protected
mogul socket

Type E and S lamp
in pink protected
mogul socket

LITHONIA INDOOR HID

ANSI Type S – Type S metal halide lamps are rated suitable for use in enclosed luminaires or in open luminaires if certain lamp manufacturer operating conditions are followed. These lamps have a standard mogul base design with a broad contact point as shown. The Type S lamp rating is currently applied to metal halide lamps 350W or greater and will be available after
January 1, 2005 for replacement of existing lamps.

385

OPTIONS & ACCESSORIES

Options & Accessories
SF

HA (Die-cast aluminum)

See Option & Accessories matrix on pages 394-395 for compatibility.

Ballast Housing Options & Accessories
SF

Single fuse. Use with 120V, 277V, 347V. Externally accessible in-line fusing isolates luminaire
from circuit. Specify tap voltage if combined with multi-tap ballast (TB1=120V, TB4=277V,
TB5=34V7) or five-tap ballast (TBV1=120V, TBV4=277V).

DF

Double fuse. Use with 208V, 240V, 480V. Externally accessible in-line fusing isolates
luminaire from circuit. Specify tap voltage if combined with multi-tap ballast (TB2=208V,
TB3=240V) or five-tap ballast (TBV2=208V, TBV3=240V, TBV6=480V).

HA

High ambient. Allows the industrial luminaires to be operated in higher ambient temperatures. TX low bay series is 55°C. TH, TE, TPG, TPGE high bay series is 65°C. Large die-cast
aluminum ballast housing included for TH, TE, TX, TPG, TPGE. Steel housing SH, SX, SPG series
is 55°C and includes external heat shield.

WL

Wet location label. Signifies that the luminaire meets all UL requirements for proper, safe
operation in environments subject to spray of non-corrosive and nonflammable liquids.
Fixture requires rigid pendant mounting or wet location HC3PC3RWT assembly.

TR

Remote ballast luminaire. Add TR to end of complete fixture catalog number. Includes
ballast housing, optic and appropriate remote optical splice box. Does not include interconnecting wiring. Ballast, optic and splice box ship separately.

RC3NP

Remote ballast luminaire with pre-wired cord. Add RC3NP to end of complete fixture
catalog number. Includes ballast housing, optic and appropriate remote optical mounting
box and 3 feet of pre-wired cable harness with male and female 20A twist lock plug (C3NP)
factory attached. Ballast, optic and splice box ship separately.

RC3NPWL

Remote ballast luminaire with pre-wired cord for wet location. Add RC3NPWL to end of
complete fixture catalog number. Same as RC3NP except listed for wet location.

SCK

Safety chain kit. Kit includes chain and attachment hardware for field installation. Add SCK
(5’), SCK84 (7’), SCK120 (10’) to fixture catalog number or order separately as SCK (5’), SCK84
(7’), SCK120 (10’).

DF
HA (Steel housing)

TR

Splice box

RC3NP/RC3NPWL

Optic Options & Accessories
CF

Charcoal filter. Used with enclosed and gasketed luminaires. Filter prevents particulate
contaminants from entering the optical assembly during start-up and cool-down periods.
Filter consists of activated charcoal granules freely suspended between multiple layers of
polyester filtering material.

GL17/GL22

Glass lens for TH A17/A22. Frequent cleaning maintains performance. (Does not meet UL
lamp rupture containment specifications.) RK1 MHINGE U kit must be specified when
ordering lens separately for field modification.

SCK

T73

LITHONIA INDOOR HID

UP

386

Corning C73. Prismatic tempered glass lens
Uplight. Glass enclosure for TE E17/E22.

CF

GL17/GL22

Ships attached
Ships separately

S F D F HA W L TR RC3NP RC3NPWL SCK C F GL17/GL22 T73 UP
● ● ● ●
●
●
● ●
●
●
●
●
●

www.lithonia.com

PSG9

Options & Accessories
EC

Emergency circuit. Factory-installed, double-contact, 120V bayonet-base quartz socket
with socket leads for use with separate external emergency power system. Reference
Quartz Lamp Wattage table for maximum wattage. 120V quartz lamp not included.

QRS

Quartz restrike system. Factory-installed, double-contact, bayonet-base quartz socket with
socket leads. Automatically switches quartz lamp on if there is a power interruption or
brownout significant enough to cause the primary HID lamp to drop out. The quartz lamp
stays on until the HID fixture restrikes. QRS does not energize during cold start of HID
luminaires. Wiring for the quartz lamp is internal to the ballast assembly; the ballast supplies
voltage required to operate the quartz lamp. The fixture must be energized for quartz lamp
to operate. Reference Quartz Lamp Wattage table for maximum wattage. 120V quartz lamp
not included.

QRSTD

Quartz restrike system time delay. Factory-installed, double-contact, bayonet-base quartz
socket with socket leads. Functions same as QRS, but quartz lamp energizes under hot and
cold starting conditions. Quartz lamp will come on when luminaire is energized and remain
on for two minutes after startup or restrike. Wiring for the quartz lamp is internal to the
ballast assembly; the ballast supplies voltage required to operate the quartz lamp. The
fixture must be energized for quartz lamp to operate. Reference Quartz Lamp Wattage
table for maximum wattage. 120V quartz lamp not included.

EC/QRS/QRSTD

OPTIONS & ACCESSORIES

Quartz Lamp Options

TX/A121/A125

–
–
100
150
150
250
250
–

TPGE/PG16AGLE/PG21AGLE

–
–
100
150
150
250
–
–

TPGE/PG16GLE/PG21GLE

–
–
100
150
150
150
150
–

TPG/PG16/PG21/PG16A/PG21A

–
100
100
150
150
250
250
500

TGR/TGL

–
100
100
150
150
250
250
500

TX/A162/A165

–
150
150
250
250
250
250
250
250
–
–
–

TX/A20/A23/A26/A30

TH/PA22/PA22N/PA22SP

–
–
–
–
–
–
–
–
–
–
–
–

100
150
150
250
250
250
250
250
250
–
–
–

100
150
150
150
150
150
150
150
150
–
–
–

100
100
100
100
–
–
–
–
–
–
–
–

–
150
150
250
250
250
250
250
250
500
500
500

–
150
150
150
150
150
150
150
150
150
150
150

–
150
150
150
150
150
150
150
150
150
150
150

100
–
–
–
–
–
–
–
–
–
–
–

–
100
100
150
150
150
150
–

–
100
100
100
100
100
–
–

–
–
100
150
150
250
250
500

–
–
100
100
100
250
250
250

–
–
100
100
100
250
250
250

100
100
100
150
150
150
–
–

TX/PA22GLE/PA22C/PA25D

TH/PA16

–
100
100
100
100
100
100
100
100
–
–
–

TH/PA25

TH/A16GL

–
100
150
250
250
250
250
250
250
500
500
500

TH/PA22L/PA22E

TH/A14/A15/A16/A17/A22

–
100
150
250
250
250
250
250
250
250
250
250

Quartz Lamp Wattage
–
150
150
150
150
150
150
150
150
–
–
–

–
150
150
150
150
150
150
150
150
150
150
150

100
150
150
150
150
150
150
150
150
–
–
–

Quartz Lamp Wattage
–
–
100
150
150
150
150
–

–
–
100
150
150
150
150
150

–
–
100
150
150
150
150
–

100
100
100
150
150
250
250
–

Add QxxxDC to fixture Catalog # to include lamp (xxx denotes wattage).

Ships attached
Ships separately

EC* QRS* QRSTD*
●
●
●

* Cannot be field installed.

PSG9

Rev. 3/19/07

www.lithonia.com

LITHONIA INDOOR HID

Metal halide HID
lamp wattage
150
175
200
250
300
320
350
400
450
750
875
1000
High pressure sodium
HID lamp wattage
50
70
100
150
200
250
400
1000

TE/E17/E22

Quartz Lamp Wattage Table
Maximum Rating for EC, QRS, QRSTD Options

387

OPTIONS & ACCESSORIES

Options & Accessories
HID Dimming Options

KW1S

KW1

KiloWatch® 50% power reduction. 120V AC control circuit for dual-level control system.
Requires additional system components. See KiloWatch® data (pages 382-383) or consult
factory.

KW4

KiloWatch® 50% power reduction. 277V AC control circuit for dual-level control system.
Requires additional system components. See KiloWatch® data (pages 382-383) or consult
factory.

KW150

KiloWatch® 50% lumen reduction. 120V AC control circuit for dual-level control system.
Requires additional system components. See KiloWatch® data (pages 382-383) or consult
factory.

KW450

KiloWatch® 50% lumen reduction. 277V AC control circuit for dual-level control system.
Requires additional system components. See KiloWatch® data (pages 382-383) or consult
factory.

KW1S

KiloWatch® II 50% power reduction. Integral sensor unit for individually controlled duallevel system. See KiloWatch® II data (page 381) or consult factory.

KW1SLT

KiloWatch® II 50% power reduction for low temperature. Integral low temperature sensor
unit for individually controlled dual-level system. See KiloWatch® II data (page 381) or
consult factory.

ISM

Individually sensored motion detector. 50% power reduction for individually controlled
GEB electronic dimming ballast. See page 381 or consult factory for details.

ISM

Cord Mounting Options and Accessories
HC3P

HC3KP
LC3P

HC3P/HC3KP

LC3KP

Hook, 3’ cord and NEMA twist-lock plug. For use where receptacle and support means are
provided by others. Includes die-cast aluminum hook, 3’ of 16-gauge, 105°C cord and
NEMA configuration twist-lock plug. Add HC3P to fixture catalog number for factory
installed or order separately as HC3P Lx-xxP (Lx-xxP denotes plug configuration. Specify
from NEMA Plug Table below). Height 3-1/2”.
Hook, 3’ cord and NEMA twist-lock plug for KiloWatch®. Identical in function to HC3P
except with NEMA L23-20P plug configuration for KiloWatch®.
Loop, 3’ cord and NEMA twist-lock plug. For use where receptacle and support means are
provided by others. Includes die-cast aluminum loop, 3’ of 16-gauge, 105°C cord and
NEMA configuration twist-lock plug. Add LC3P to fixture catalog number for factory
installed or order separately as LC3P Lx-xxP (Lx-xxP denotes plug configuration. Specify
from NEMA Plug Table below). Height 3-1/2”.
Loop, 3’ cord and NEMA twist-lock plug for KiloWatch®. Identical in function to LC3P except
with NEMA L23-20P plug configuration for KiloWatch®.

NEMA Plug Table

LITHONIA INDOOR HID

Ships attached

388

LC3P/LC3KP

Fixture option field
Hook, 3’
Loop, 3’
cord & plug
cord & plug
HC3P
LC3P
HC3P
LC3P
HC3P
LC3P
HC3P
LC3P
HC3P
LC3P
HC3P
LC3P
HC3P20
LC3P20
HC3P20
LC3P20
HC3P20
LC3P20
HC3P20
LC3P20

Ships attached
Ships separately

Fixture voltage field
Voltage
120
208
240
277
347
480
120
208
240
277

TB ballast
TB1
TB2
TB3
TB4
TB5
-TB1
TB2
TB3
TB4

TBV
ballast
TBV1
TBV2
TBV3
TBV4
-TBV6
TBV1
TBV2
TBV3
TBV4

NEMA
plug
configuration
L5-15P
L6-15P
L6-15P
L7-15P
L37-20P
L8-20P
L5-20P
L6-20P
L6-20P
L7-20P

Ships separately
Accessory item
Amp
rating
15
15
15
15
20
20
20
20
20
20

Catalog number
HC3P L5-15P
HC3P L6-15P
HC3P L6-15P
HC3P L7-15P
HC3P L37-20P
HC3P L8-20P
HC3P L5-20P
HC3PL6-20P
HC3P L6-20P
HC3P L7-20P

KW1 KW4 KW150 KW450 KW1S KW1SLT ISM HC3P HC3KP LC3P LC3KP
●
●
●
●
●
●
● ●
●
●
●
●
●

www.lithonia.com

PSG9

Options & Accessories
OPTIONS & ACCESSORIES

Cord Mounting Options and Accessories (continued)
HC3PC3RWT

SC3P

SC3PD

Hook, 3’ cord, NEMA twist-lock and receptacle for wet location. For use where support means
are provided by others. Includes grommeted die-cast aluminum safety hook, 3’ of 16-gauge,
105°C cord and NEMA twist-lock 20A plug and compatible NEMA receptacle.
Steel hook, 3’ cord and NEMA twist-lock plug. Used on steel ballast housing only. For
use where receptacle and support means are provided by others. Includes steel hook, 3’ of
16-gauge, 105°C cord and NEMA configuration twist lock plug. 15A plug standard for 120V,
208V, 240V, 277V; 20A plug standard for 347V, 480V. Height 2-5/8”.
Steel hook, 3’ cord with NEMA twist-lock plug and 3’ low voltage cord. Same as SC3P with
3’ of low voltage control cord for 0-10VDC dimming. Used on steel ballast housing with GEB
electronic ballast only.

HC3PC3RWT

SC3P

Reloc® Mounting Options
HOCS

Hook, cord and Reloc® OCS connector. For use where support means are provided by others.
Requires Reloc® wiring system. Includes die-cast aluminum hook, 5’ of 16-gauge, 105°C
white cord and Lithonia Reloc® module. Allows the desired hot conductors needed to
energize the fixture to be selected in the field. Allows fixture to be removed from line
without interruption of branch circuit. Factory prewired. Height 3-1/2”. In Canada, available
in 120V or 347V only. To order, specify voltage. For additional information, see Reloc® OCS
component on page 692.

LOCS

Loop, cord and Reloc® OCS connector. For use where support means are provided by others.
Requires Reloc® wiring system. Includes die-cast aluminum loop, 5’ of 16-gauge, 105°C
white cord and Lithonia Reloc® module. Allows the desired hot conductors needed to
energize the fixture to be selected in the field. Allows fixture to be removed from line
without interruption of branch circuit. Factory prewired. Height 3-1/2”. In Canada, available
in 120V or 347V only. To order, specify voltage. For additional information, see Reloc® OCS
component on page 692.

OCS

Hook, cord and Reloc® OCS connector. For use where support means are provided by others.
Requires Reloc® wiring system. Includes steel hook, 5’ of 16-gauge, 105°C white cord
and Lithonia Reloc® module. For SH/SX/SPG steel housing only. Allows the desired hot
conductors needed to energize the fixture to be selected in the field. Allows fixture
to be removed from line without interruption of branch circuit. Factory prewired. Height 31/2”. In Canada, available in 120V or 347V only. To order, specify voltage. For additional
information, see Reloc® OCS component on page 692.

SC3PD

HOCS

LOCS

Ships attached
Ships separately

PSG9

HC3PC3RWT
●

SC3P
●

SC3PD
●

HOCS LOCS OCS
●
●
●

www.lithonia.com

LITHONIA INDOOR HID

OCS

389

OPTIONS & ACCESSORIES

Options & Accessories
Power Hook Options & Accessories
LCPP/LCKPP

LCPP

LCKPP

PPH/PPHKR

PPH

PPHKR

TPH

TPH/TPHKR

TPHKR

LUCP

Loop, cord and plug. Use with PPH and TPH only. Includes loop, 14” of 16-gauge, 105°C cord
and twist-lock 14A non-NEMA plug configuration for power hooks. Receptacle is part of
PPH or TPH accessory. Add LCPP to fixture catalog number for factory installed or order
separately as LCPP.
Loop, cord and plug for KiloWatch®. Use with PPHKR and TPHKR only. Includes loop,14” of
16-gauge, 105°C cord and twist-lock NEMA L23-20P plug for power hooks for KiloWatch®.
Receptacle is part of TPHKR and PPHKR accessory. Factory installed.
Pendant power hook. UL listed as primary disconnect, load break device. Threaded 3/4”
top entry. Fixture requires LCPP option (loop, cord and plug). Add PPH to fixture catalog
number or order separately as PPH xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277,
347, 480.) Height 5-1/8”; width and depth 4-1/2”.
Pendant power hook for KiloWatch® system. UL listed as primary disconnect, load break
device. Threaded 3/4” top entry. Fixture requires LCKPP option (loop, cord and plug for
KiloWatch
KiloWatch® system). Add PPHKR to fixture catalog or order separately as PPHKR xxx. (xxx
– denotes voltage. Specify 120, 208, 240, 277, 347, 480.) Height 5-1/8”; width and depth 41/2”.
Through-wire power hook. UL listed as primary disconnect, load break device. Permits
side entry for 1-1/4” or 3/4” conduit through concentric knockouts. Fixture requires LCPP
option (loop, cord and plug). Add TPH to fixture catalog number or order separately as
TPH xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277, 347, 480.) Height 6-1/4”; width
and depth 4-1/2”.
Through-wire power hook for KiloWatch® system. UL listed as primary disconnect, load break
device. Permits side entry for 1-1/4” or 3/4” conduit through concentric knockouts. Fixture
requires LCKPP option (loop, cord and plug for KiloWatch
KiloWatch® system)
system).. Add TPHKR to
fixture catalog or order separately as TPHKR xxx. (xxx – denotes voltage. Specify 120, 208, 240,
277, 347, 480.) Height 6-1/4”; width and depth 4-1/2”.

Universal Power Module Hook & Loop Mounting Options
LUCP

LUCPSF

LUCPDF

LUCPSF

UPM1

LITHONIA INDOOR HID

LUCPDF

390

Loop, universal cord and plug. Requires UPM1 option (universal power module with
hook adapter). Provides die-cast aluminum loop, 3’ of 16-gauge, 105°C cord and UCP
plug. Factory prewired. Height is 3-1/2”.
Loop, universal cord, plug with single fusing. Requires UPM1 (universal power module
with hook adapter)
adapter).. Provides die-cast aluminum loop, 3’ of 16-gauge, 105°C cord and UCP
plug. Factory prewired. Height is 3-1/2”.
Loop, universal cord, plug with double fusing. Requires UPM1 (universal power module
with hook adapter)
adapter).. Provides die-cast aluminum loop, 3’ of 16-gauge, 105°C cord and UCP
plug. Factory prewired. Height is 3-1/2”.
Universal power module with hook adapter. UL listed as primary disconnect, load break
device. Concentric knockouts for side entry of 1-1/4” or 3/4” conduit. Threaded 3/4” top
entry for pendant. Fixture requires LUCP options (loop, universal cord and plug).
Allows surface, through-wire or pendant mounting. Add UPM1 to fixture catalog number or order separately as UPM1 xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277,
347, 480.) Height 7”, width and depth 4-1/2”.

UPM1

LCPP LCKP PPH PPHKR TPH TPHKR LUCP LUCPSF LUCPDF UPM1
Ships attached
Ships separately

●
●

●

www.lithonia.com

●
●

●

●

●

●

●
●

PSG9

Options & Accessories
Universal cord and plug. Requires UPM (universal power module) option. 16-gauge,
105°C cord and plug. Connect to UPM to provide complete power module assembly.
Factory prewired module.

UCP

UCPSF

Universal cord and plug with single fuse. Requires UPM (universal power module)
option. 16-guage, 105° C cord and plug module with single fuse (120V, 277V). Connect
to UPM to provide complete power module assembly. Fuse is factory-installed in UCPSF
plug module. Factory prewired.

UCPDF

Universal cord and plug with double fuse. Requires UPM (universal power module)
option. 16-guage, 105° C cord and plug module double fuse (208V, 240V, 480V). Connect
to UPM to provide complete pwer module assembly. Fuses are factory-installed in UCPDF
plug module. Factory prewired.
Universal power module. UL listed as primary disconnect, load break device. Concentric
knockouts for side entry of 1-1/4” or 3/4” conduit. Threaded 3/4” top entry. Fixture
requires UCP (universal cord and plug) options. Allows flat horizontal surface, throughwire or pendant mounting. Add UPM to fixture catalog number or order separately as
UPM xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277, 347, 480.) Height 3-1/2”,
width and depth 4-1/2”.

UPM

UCP

UCPSF

OPTIONS & ACCESSORIES

Universal Power Module Mounting Options

UCPDF

Box Mounting Options & Accessories
TOB

Through-wire outlet box. Combination outlet box and splice compartment. Permits side
entry for 1-1/4” or 3/4” conduit or top entry for 3/4” conduit through concentric knockouts.
May be suspension or surface mounted. Height 2-7/8”; width and depth 4-1/2”.

TOBP

Through-wire outlet box plug-in. Provides plug-in flexibility of conventional power hook
and reduces overall height. Permits side entry for 1-1/4” or 3/4” conduit through concentric knockouts. Female receptacle part of TOBP box ships separately. Male plug is factory
installed to ballast housing. Not rated as a load break device. Height 2-7/8”; width and depth
4-1/2”.

PBP

Pendant box plug-in. Pendant-mount plug-in outlet box provides plug-in flexibility of
conventional power hook. Female receptacle part of PBP box ships separately. Male plug is
factory-installed to ballast housing. Not rated as a load break device. Threaded 3/4” entry
permits top entry of pendant stem. Height 4-1/2”; width and depth 4-1/2”.

PSB

Pendant splice box. Permits pendant mounting of TG and SH/SX/SPG steel housing series. TG
box has 3/4” threaded top entry. SH/SX/SPG box has 3/4" top knockout.

PM

Pendant splice box. Permits pendant mounting of TGL and TGR series. Die-cast aluminum
box has 3/4” threaded top entry.

UPM

TOB

TOBP

PBP

UCP UCPSF UCPDF UPM TOB TOBP PBP PSB PM
Ships attached
Ships separately

PSG9

●

●

●

●
●

●
●

●
●

●

●

www.lithonia.com

PM assembled

LITHONIA INDOOR HID

PSB

391

OPTIONS & ACCESSORIES

Options and Accessories
Drawings are for dimensional detail only and may not
represent actual mechanical configuration.
HKM

Mounting Hooks
HKM

Fixture hook male. Die-cast aluminum construction with spring steel safety clasp. Overall
height is 3-3/4” including 1” of threaded nipple. Thread diameter is 3/4”.

HKF

Fixture hook female. Die-cast aluminum construction with spring steel safety clasp with
coupling added for female entry. Overall height is 5-1/4” including threaded coupling.
Thread diameter is 3/4”.

HKMG

Fixture hook male grommeted. Die-cast aluminum construction with spring steel safety
clasp. Gasketed cord exit design keeps dirt from entering hook/cord entry. Overall height
is 3-3/4” including 1” of threaded nipple. Thread diameter is 3/4”.

LPM

Fixture loop male. Die-cast aluminum construction with closed loop design. Overall height
is 3-3/4” including 1” of threaded nipple. Thread diameter is 3/4”.

LPF

Fixture loop female. Die-cast aluminum construction with closed loop design with coupling added for female entry. Overall height is 5-1/4” including threaded coupling. Thread
diameter is 3/4”.

LPMG

Fixture loop male grommeted. Die-cast aluminum construction with closed loop design.
Gasketed cord exit design keeps dirt from entering Loop/cord entry. Overall height is
3-3/4” including 1” of threaded nipple. Thread diameter is 3/4”.

HKF

HKMG
LPM

LPF
LPMG

Mounting Bars

SMB

SMB

Single mounting bar. White painted steel channel with 3/4” pipe couplings suspend remote ballast housing at one end with remote reflector assembly at the other. SMB includes
end snap-in closure strips for wire access. Order as SMB18 for 18” (overall length) or SMB24
for 24” (overall length). Center line of pipe couplings are 3” from each end.

TMB

Twin mounting bar. White painted steel channel with 3/4” pipe couplings suspends two
complete fixtures, one at each end. Order as TMB30 for 30” (overall length) or TMB48 for
48” (overall length). Centerlines of pipe couplings are 3” from each end.

WB

TG Series wall-mounting bracket. Extruded aluminum wall bracket for TG, TGL, TGR luminaires. Bracket mounts directly to flat, vertical surface with four bolts (not included). Fixture
slides directly onto WB. All wiring connections are made inside wall mounting bracket. TG
requires PSB option (pendant splice box on page 391). TGL and TGR fixture require PM
option (pendant splice box on page 391).

2-7/8"

TMB
2-7/8"

WB

5-1/2"

Wireguards for Hi-Tek® Aluminum High Bays and Low Bays

15"

4-1/2"
2"

WGA

Wireguard for Hi-Tek® open aluminum high bay reflectors. Use with TH A15/A16/A17/A22
and SH A15/A16 open aluminum reflector high bays. Add WG to fixture catalog number or
order separately as WGxxx. (xxx – denotes reflector. Specify A15, A16, A17, A22.)

WGG

Wireguard for enclosed high bay reflectors. Use with TE E17/E22; TH A17 with GL17/A22
with GL22; TPGE PG16GLE/PG16AGLE/PG21GLE/PG21AGLE reflector high bays. Wireguard
is factory installed to glass lens door. Must be ordered with fixture. Add WG to fixture
catalog number.

WG

Wireguard for Hi-Tek® aluminum low bays. Use with TX A20/A23/A26/A30 or SX A23. Must
be ordered with fixture. Add WG to fixture catalog number. Wireguard is factory attached
to lens door. Add WG to fixture catalog number.

13-5/8"

LITHONIA INDOOR HID

WGA

392

WGG

WG

HKM
Ships attached
Ships separately

HKF HKMG LPM LPF LPMG SMB TMB WB WGA WGG WG
●

●

●

www.lithonia.com

●

●

●

●

●

●

●

●

●

PSG9

Options and Accessories
LGA

LGA

Louver guard for open aluminum high bay reflectors. Use with TH A16/A17/A22 or SH A16
open aluminum high bays. Must be ordered with fixture. Reflector requires factory
modification for louver mounting. Add LGAxx to fixture catalog number. (xx – denotes
reflector. Specify 16, 17, 22.)

LGG

Louver guard for enclosed aluminum high bay reflectors. Use with TE E17/E22 enclosed
aluminum high bays. Must be ordered with fixture. Reflector requires factory modification
for louver mounting. Louver mounts to reflector above lens door. Add LGGxx to fixture
catalog number. (xx – denotes reflector size. Specify 17, 22.)

Wireguards DuraBay® Prismatic Glass High Bays

WGPG

WGPG

Wireguard for open prismatic glass high bay reflectors. Use with prismatic glass reflector
high bay TPG PG16/PG21 and shrouded prismatic glass reflector high bay TPG PG16A/
PG21A. Wireguard covers bottom opening of reflector. Field installed to bottom of reflector. Add WGxxxx to fixture catalog number or order separately as WGxxxx. (xxxxx – denotes
reflector. Specify PG16, PG21, PG16A, PG21A.)

GFWG

Wireguard for enclosed prismatic glass high bay reflectors. Use with enclosed prismatic
glass reflector high bay TPGE PG16GLE/PG21GLE/PG16AGLE/PG21AGLE. Two-piece
wireguard protects top reflector and bottom glass lens door. Top portion field installed to
reflector neck casting. Bottom portion factory installed to glass lens door. Add GFWGxx to
fixture catalog number or order separately as GFWGxx. (xx – denotes reflector size. Specify
16, 21.) Optic, top wireguard and lens door with wireguard ship separately.

GFWG

FWG

Wireguard Acrylume® Prismatic Acrylic High Bays and Low Bays
FWG

LGG

OPTIONS & ACCESSORIES

Louver Guard Accessories

Full wireguard. Use with the TH high bay or TX low bay Acrylume® fixtures. Attaches to
bottom of ballast housing. Ships separately as: FWG U (Unit).

Decorative Shades
Fixture series and size
TH A16 and TH A17
TH A17 with WGA,
WGG or LGA
TH A22
TH A22 with WGA,
WGG or LGA
TE17
TE E22

Cylinder DCY
DCY19 400 (color)
DCY22 400 (color)

Square DSQ
DSQ19 400 (color)
DSQ22 400 (color)

Hexagonal DHX
DHX19 400 (color)
DHX22 400 (color)

Dia.
19”
22 ½”

Height
30”
30”

DCY24 400 (color)
DCY26 1000 (color)

DSQ24 400 (color)
DSQ26 1000 (color)

DHX24 400 (color)
DHX26 1000 (color)

24”
26”

30”
30”

DCY22 400 (color)
DCY26 1000 (color)

DSQ22 400 (color)
DSQ26 1000 (color)

DHX22 400 (color)
DHX26 1000 (color)

22½”
26”

30”
30”

DCY

DSQ

DHX

LGA LGG
Ships attached
Ships separately

PSG9

●

●

WGPG GFWG FWG DCY
●

●

●

●

DSQ

DHX

●

●

www.lithonia.com

LITHONIA INDOOR HID

24-gauge steel construction with baked polyester enamel finish. Designed for pendant mounting on
rigid conduit only. Not for use on swivel hangers or any self-leveling hanging device. Available in all
architectural colors. Custom colors may involve substantial setup fees; consult factory. Mounting and
fixture attachment hardware not included.

393

LITHONIA INDOOR HID

OPTIONS & ACCESSORIES

Options & Accessories

394

Ships
attached
Ballast Housing Options & Accessories
SF
Single fuse; 120/277/347V only1
DF
Double fuse; 208/240/480V only1
HA
55°C ambient operation2
HA
65°C ambient operation2
WL
Wet location; UL Listed
TR
Remote ballast luminaire
RC3NP
Remote ballast (TR) luminaire with pre-wired cord and plug3
RC3NPWL
Remote ballast (TR) luminaire with pre-wired cord for wet location
SCK
Safety chain kit 60”
SCK84
Safety chain kit 84”
SCK120
Safety chain kit 120”
Optic Options
CF
Charcoal filter3
GL
Glass lens (tempered) door enclosure
T73
Corning C73 prismatic tempered glass lens door enclosure
UP
Uplight glass enclosure3
Quartz Lamp Options
EC
Emergency circuit (lamp not included); see page 387 for maximum wattage
QRS
Quartz restrike system (lamp not included); see page 387 for maximum wattage
QRSTD
QRS time delay (lamp not included); see page 387 for maximum wattage
HID Dimming Options
KW1
KiloWatch® 120V control relay; 50% wattage reduction
KW4
KiloWatch® 277V control relay; 50% wattage reduction
KW150
KiloWatch® 120V control relay; 50% light (lumen) reduction
KW450
KiloWatch® 277V control relay; 50% light (lumen) reduction
KW1S
KiloWatch® II integral sensor unit; 50% wattage reduction3
KW1SLT
KiloWatch® II integral low temperature sensor unit; 50% wattage reduction3
ISM
Integral sensor unit; 50% wattage reduction (GEB electronic ballast only)
Cord Mounting Options
HC3P
Hook, 3’ cord & 15A NEMA twist-lock plug (20A for 480V)1,3
HC3KP
Hook, 3’ cord & NEMA L23-20P KiloWatch® plug3
LC3P
Loop, 3’ cord & 15A NEMA twist-lock plug (20A for 480V)1,3
LC3KP
Loop, 3’ cord & NEMA L23-20P KiloWatch® plug3
HC3PC3RWT
Wet location hook, cord and receptacle1
SC3P
Steel hook, 3’ cord and 15A NEMA twist-lock plug
SC3PD
Steel hook, 3’ cord and 15A NEMA twist-lock plug and 3’ low voltage control cord
Reloc® Mounting Options
HOCS
Hook, 5’ white cord, Reloc® OCS1,3,4
LOCS
Loop, 5’ white cord, Reloc® OCS1,3,4
OCS
Steel hook 5’ white cord, Reloc® OCS
Power Hook Options
LCPP
Loop, cord and plug; requires PPH or TPH3
LCKPP
Loop, cord and KiloWatch® plug; requires PPHKR or TPHKR3
PPH
Pendant power hook outlet box; luminaire requires LCPP3
PPHKR
Pendant power hook outlet box for KiloWatch®; luminaire requires LCKPP3
TPH
Through-wire power hook outlet bos; luminare requires LCPP3
TPHKP
Through-wire power hook outlet box for KiloWatch®; luminaire requires LCKPP3

www.lithonia.com

Ships
separately

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

●
●

●
●
●
●
●

●
●
●
●
●
●

NOTES:
1 Must specify voltage tap for TB and TBV in catalog number voltage
field (TB1=120V, TB2=208V, TB3=240V, TB4=277V, TBV1=120V,
TBV2=208V, TBV3=240V, TBV4=277V, TBV6=480V).
2 Not available all wattages and voltages. Consult factory.
3 Cannot be combined with (WL) wet location option.
4 Available 120V or 347V only in Canada.
5 Requires (PSB) pendant splice box option.
6 Requires (PM) pendant splice box option.

PSG9

Options & Accessories

Optic
options
Quartz lamp
options
HID dimming
options
Cord mounting
options

TX PA25D

TX PA25ALE

TX PA22GLE

TX PA22C

TXF PA25ALEF

TXF A30F

TX A30

TXD A23

TX A26

TX A23

TX A20

TX A125/A165

TGR

TGL

TG

SX A23

TPGE

TPG

THD A15/A16

TH PA22*/PA25

TH A17/A22

TH A16/A16GL

TH A15

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

DF

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

HA (55° C)

■ ■ ■ ■ ■ ❏ ❏ ❏ ❏ ❏ ■ ❏ ❏ ❏

HA (65° C)

■ ■ ■ ■ ■

WL

■

TR

■ ■ ■ ■ ■ ■

■ ■

RC3NP

■ ■ ■ ■ ■ ■

■ ■

RC3NPWL

■

■ ■ ■ ■

■ ■ ■

■ ■ ■

■

■ ■
■ ■ ■ ■ ■ ■
■ ■ ■ ■

■ ❏ ❏ ■ ■ ■ ■
■

■ ■ ■ ■

■ ■ ■ ■

■

■ ■ ■ ■

■ ■ ■ ■

■

■ ■ ■ ■

SCK

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■

■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

SCK84

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■

■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

SCK120

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■

■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

■

■

■ ■ ■

■

■
■

GL17/GL22
■

T73
UP

■

EC

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

KW1

■ ■ ■ ■ ■ ■

■ ■

■2 ■2 ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

KW4

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

KW150

■ ■ ■ ■ ■ ■

■ ■

■2 ■2 ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

KW450

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■

KW1S

■ ■ ■ ■ ■ ■

■ ■ ■

■

■ ■ ■ ■

KW1SLT

■ ■ ■ ■ ■ ■

■ ■ ■

■

■ ■ ■ ■

QRS
QRSTD

■ ■ ■ ■

2

2

2

2

■ ■ ■ ■ ■ ■ ■

■

HC3P

■ ■ ■ ■ ■ ■

■ ■

■5 ■6 ■6 ■ ■ ■ ■

■

■ ■ ■ ■

HC3KP

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LC3P

■ ■ ■ ■ ■ ■

■ ■

■5 ■6 ■6 ■ ■ ■ ■

■

■ ■ ■ ■

LC3KP

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

6

6

■

HC3PC3RWT
SC3P

■ ■ ■ ■ ■

SC3PD

■ ■ ■ ■ ■

6

6

■
■

HOCS

■ ■ ■ ■ ■ ■

■ ■

■5 ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LOCS

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LCPP

■ ■ ■ ■ ■ ■

■ ■

■5 ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LCKPP

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

PPH

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

PPHKR

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

TPH

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

TPHKP

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

OCS

■ ■ ■ ■

5

■

www.lithonia.com

LITHONIA INDOOR HID

Reloc®
mounting
options

TH A14

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

ISM

Power hook
options

Low bays

SF

CF

PSG9

TE E17/E22

SH PA22

SH A16

SH A15

SH A14
Ballast housing
options & accessories

SPG PG15

High bays

■ = Option
available

OPTIONS & ACCESSORIES

❏ = Standard

395

LITHONIA INDOOR HID

OPTIONS & ACCESSORIES

Options & Accessories

396

Ships
attached
Universal power module hook and loop mounting
LUCP
Loop, cord and plug; for use with UPM11,2
LUCPSF
LUCP, single fuse; dead front fusing; 120/277V only; for use with UPM11,2
LUCPDF
LUCP, double fuse; dead front fusing; 208/240/480V only; N/A multi-tap ballast; for use with UPM11,2
UPM1
Universal power module/hook adapter (specify voltage); luminaire requires LUCP, LUCPSF or LUCPDF
Universal power module mounting
UCP
Universal cord and plug; for use with UPM1,2,3
UCPSF
UCP with single fuse; dead front fusing; for use with UPM1,2,3
UCPDF
UCP with double fuse; dead front fusing; for use with UPM1,2,3
UPM
Universal power module (specify voltage); luminaire requires UCP, UCPSF or UCPDF
Box mounting
TOB
Through-wire outlet box2
TOBP
Through-wire outlet box plug-in1,2
PBP
Pendant box plug-in1,2
PSB
Pendant splice box (steel box)2
PM
Pendant splice box (die-cast aluminum box)
Mounting hooks and loops
HKM
Fixture hook, male
HKF
Fixture hook, female (3/4” threaded coupler)
HKMG
Grommeted fixture hook, male
LPM
Fixture loop, male
LPF
Fixture loop, female (3/4” threaded coupler)
LPMG
Grommeted fixture loop, male
Mounting bars
SMB18
18” single-mounting bar; requires TR remote ballast option2,4
SMB24
24” single-mounting bar; requires TR remote ballast option2,4
TMB30
30” twin-mounting bar2
TMB48
48” twin-mounting bar2
WB
TG Series wall mounting bracket
Wireguards
WGA
Wire guard for open Hi-Tek® high bay reflectors (specify reflector size 15, 16, 17 or 22)
WGG
Wireguard for enclosed high bay reflectors (add WG to catalog number)
WG
Wire guard for Hi-Tek® low bays
LGA
Louver guard for open Hi-Tek® high bays (specify reflector size 16, 17 or 22)
LGG
Louver guard for enclosed Hi-Tek® high bays (specify reflector size 17 or 22)
WGPG
Wire guard for prismatic glass high bays (specify reflector size 16, 21, 16A or 21A)
GFWG
Full wire guard enclosed glass optic
FWG
Full wire guard for Acrylume® optics
Decorative shades
DCY
Cylinder shade (specify reflector size and color)5
DSQ
Square shade (specify reflector size and color)5
DHX
Hexagonal shade (specify reflector size and color)5
Paint options
CR
Enhanced corrosion-resistant finish (polyester), housing and reflector6
CRT
Non-stick protective coating, housing and reflector6
Lamp options
LPI
Lamp shipped in carton with fixture (N/A with incandescent)
W/LAMP
Lamp ships separately (N/A with incandescent)

www.lithonia.com

Ships
separately

●
●
●
●
●
●
●
●

●
●
●
●

●
●
●

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
N/A
N/A

N/A
N/A

●
●

NOTES:
1 Must specify voltage tap for TB and TBV in catalog number voltage field (TB1=120V, TB2=208V,
TB3=240V, TB4=277V, TBV1=120V,
TBV2=208V, TBV3=240V, TBV4=277V,
TBV6=480V).
2 Cannot be combined with (WL) wet location
option.
3 Available 120V or 347V only in Canada.
4 Requires (TR) remote ballast option.
5 Pendant mount on rigid conduit. Not for use
with any self-leveling hanger.
6 Consult factory for environmental compatibility.
7 Requires (PM) pendant splice box option.
8 Must be ordered with (GL17/GL22) tempered
glass lens door enclosure.
9 Housing only.

Optional Architectural Colors
DNA
DSB
DMB
DTG
DSS
DBL
DWH
DGC
DBR
DDB

Natural aluminum
Steel blue
Medium bronze
Tennis green
Sandstone
Black
White
Charcoal gray
Bright red
Dark bronze

PSG9

Options & Accessories

TX PA25D

TX PA25ALE

TX PA22GLE

TX PA22C

TXF PA25ALE

TXF A30F

TX A30

TXD A23

TX A26

TX A23

TX A20

TX A125/A165

TGR

■ ■ ■ ■ ■ ■

■ ■

■ ■ 7 ■7 ■ ■ ■ ■

■

■ ■ ■ ■

LUCPSF

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LUCPDF

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

UPM1

■ ■ ■ ■ ■ ■

■ ■

■ ■ 7 ■7 ■ ■ ■ ■

■

■ ■ ■ ■

UCP

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■

■

■ ■ ■ ■

UCPSF

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■

■

■ ■ ■ ■

UCPDF

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■

■

■ ■ ■ ■

■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■

■

■ ■ ■ ■

■ ■ ■ ■

■

■ ■ ■ ■

UPM

Box mounting

TOB

■ ■ ■ ■

7

■ ■ ■ ■ ■ ■

Mounting hooks
and loops
Mounting bars

7

■

TOBP

■ ■ ■ ■ ■ ■

■ ■ ■ ■

■

■ ■ ■ ■

PBP

■ ■ ■ ■ ■ ■

■ ■ ■ ■

■

■ ■ ■ ■

❏ ❏ ❏ ❏ ❏ ❏

❏ ❏ ❏ ❏

PSB

■ ■ ■ ■ ■ ❏ ❏ ❏ ❏ ❏ ❏ ❏

■ ■
■ ■

❏ ❏

HKM

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

HKF

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

HKMG

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LPM

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LPF

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

LPMG

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■ ■

■ ■ ■ ■ ■ ■ ■ ■

■

■ ■ ■ ■

SMB18

■ ■ ■ ■ ■ ■

■

SMB24

■ ■ ■ ■ ■ ■

■

TMB30

■ ■ ■ ■ ■ ■

■

TMB48

■ ■ ■ ■ ■ ■

■
■

WB
WGA

■ ■

■ ■ ■
■

WGG
Wireguards

7

7

PM

■ ■ ■ ■
■

■

■ ■ ■ ■

■

■

■ ■
■
■
■

GFWG

Decorative
shades

■

■

■ ■ ■

■

DSQ

■

■ ■ ■

■

DHX

■

■ ■ ■

■

Lamp
Paint
options options

■

CR

■ ■ ■ ■ ■ ■9

■9 ■9

CRT

■

■ ■

■

9

■ ■ ■ ■

■ ■ ■

❏

LPI
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

■

■9 ■9 ■ 9 ■ 9

9

❏
■ ■

www.lithonia.com

■ ■ ■ ■ ■ ■ ■ ■

■ ■ ■ ■ ■ ■ ■

LITHONIA INDOOR HID

■

DCY

W/LAMP

■ ■ ■ ■

■ ■ ■ ■

LGG

FWG

■

■

WG
LGA

■ ■ ■ ■
■

■

■8

WGPG

PSG9

TGL

TG

SX A23

TPGE

TPG

THD A15/A16

TH PA22/PA25

TH A17/A22

TH A15

TH A14

TE

SPG

SH PA22

SH A16

SH A15

Universal power
module hook and
loop mounting

LUCP

Universal power
module mounting

SH A14

■ = Option
available

TH A16/A16GL

Low bays

OPTIONS & ACCESSORIES

High bays
❏ = Standard

397



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Modify Date                     : 2007:03:19 11:09:50-04:00
Create Date                     : 2006:03:15 15:31:36-05:00
Metadata Date                   : 2007:03:19 11:09:50-04:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:e549cafe-ecdb-4c58-be8d-521a9141c70b
Instance ID                     : uuid:56511bee-06ef-4642-a6e0-861ba922b82e
Has XFA                         : No
Page Count                      : 52
EXIF Metadata provided by EXIF.tools

Navigation menu