Schneider Electric DIGEST 175 Load Centers 40820 Catalog

115931-Catalog 115931-Catalog 115931-Catalog 785901 Batch6 unilog cesco-content

119972-Catalog 119972-Catalog 119972-Catalog 785901 Batch7 unilog cesco-content

40820-Catalog 40820-Catalog 40820-Catalog 785901 Batch5 unilog cesco-content

2014-07-04

: Pdf 40820-Catalog 40820-Catalog 047569 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 13

www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-5
QO® Load Centers Indoor-1Ø, Main Lug
Class 736, 1130 / Refer to Catalog 1100CT0501
1Ø3W Load Centers, 120/240 Vac, UL Listed
Main Circuit Breaker Kits
Table 1.16: Main Lugs (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI, and QO-PL branch circuit breakers from pages 1-2 and 1-3)
Mains
Rating Spaces Max. 1P
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior Indoor Cover with Door
(Order Separately) Main Wire Size
AWG/kcmil Equipment Ground Bar
Kit (Order Separately) Box No.
See Page
1-17
Flush
Cat. No. Surface
Cat. No. $ PriceCat. No. $ Price Al Cu Cat. No. $ Price
I
N
D
O
O
R
Fixed Mains—Factory-Installed Main Lugs—10 kA Short Circuit Current Ratingb
30 A 2 2 0 41.70 QO2L30Scd 41.70
Cover Included—Without Door
12–10 14–10 PK3GTA1 11.40 1
70 A 2 4 2 69.00 QO24L70F/Sef 69.00 12–3 14–4 PK4GTA 10.80 2
100 A
612 6 87.00 QO612L100F/Seg 87.00 8–1 PK7GTA 11.70 4
90.00 QO612L100DF/Seg 90.00 Cover Included—With Door 8–1 PK7GTA 11.70 4
816 8 131.00 QO816L100F/Seg 131.00 Cover Included—Without Door 8–1 PK7GTA 11.70 4
143.00 QO816L100DF/Seg 143.00 Cover Included—With Door
100 A 612 6 111.00 QO612L100DFCU/SCUegh 111.00 Cover Included—With Door 8–1 PK7GTA 11.70 4
816 8 174.00 QO816L100DFCU/SCUegh 174.00 Cover Included—With Door 8–1 PK7GTA 11.70 4
125 A 4 8 4 93.00 QO148L125GF/Sei 93.00 Cover Included—Without Door 12–2/0 14–2/0 PK7GTAl21
Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Cu Busbj
125 A
12 12 0 196.70 QO112L125G 159.00 QOC16UF QOC16US 37.70
6–2/0
PK9GTAl6
12 24 12 235.70 QO11224L125G 198.00 QOC16UF QOC16US 37.70 PK15GTAl6
16 16 0 255.70 QO116L125G 218.00 QOC24UF QOC24US 37.70 PK12GTAl7
16 24 8 300.70 QO11624L125G 263.00 QOC24UF QOC24US 37.70 PK15GTAl7
20 20 0 271.70 QO120L125G 234.00 QOC24UF QOC24US 37.70 PK15GTAl7
20 24 4 370.70 QO12024L125G 333.00 QOC24UF QOC24US 37.70 PK15GTAl7
24 24 0 381.70 QO124L125G 344.00 QOC24UF QOC24US 37.70 PK15GTAl7
32 32 0 434.60 QO132L125G 395.00 QOC32UF Use Flush 39.60 PK23GTA, LK100ANl8
Convertible Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Rating , QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Cu Busbj
150 A
20 30 10 419.00 QO12030L150G 332.00 QOC30UF QOC30US 87.00
6–250
PK23GTA, LK100ANl9
24 24 0 431.00 QO124L150G 344.00 QOC30UF QOC30US 87.00 PK15GTAl9
30 30 0 437.00 QO130L150G 350.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl9
200 A
12 12 0 353.00 QO112L200G 266.00 QOC30UF QOC30US 87.00
6–250
PK15GTAl9
24 36 12 819.00 QO12436L200TFTk732.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl10
30 30 0 494.00 QO130L200G 407.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl9
30 40 10 554.00 QO13040L200G 467.00 QOC30UF QOC30US 87.00 PK23GTA, LK100ANl9
40 40 0 746.00 QO140L200G 659.00 QOC40UF QOC40US 87.00 PK23GTA, LK100ANl10
40 60 20 944.00 QO14060L200G 857.00 QOC40UF QOC40US 87.00 (2) PK15GTAl10
42 52 10 921.00 QO14252L200G 810.00 QOC42UF QOC42US 111.00 (2) PK15GTAl11
225 A 42 42 0 828.00 QO142L225G 717.00 QOC42UF QOC42US 111.00 6–300 PK23GTA, LK100ANl11
Fixed Mains—Factory-Installed Main Lugs—65 kA Short Circuit Current Ratingbj
400 A 30 30 0 1641.00 QONQ30LS400 (Int) 1080.00 NC50NQVF NC50NQVS 486.00 (1) 1/0–750 PK27GTAn
or
PK15GTA6
33.80
53.00
15
MH50 (box)o75.00 or (2) 1/0–300
400 A 42 42 0 1746.00 QONQ42LS400 (Int)m1185.00 NC50NQVF NC50NQVS 486.00 (1) 1/0–750 15
MH50 (box) 75.00 or (2) 1/0–300
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
cWill not accept QO-EPD or Qwik-Gard® QO-GFI or QO-AFI circuit breakers.
dMains rated 25 A when Al wire is used.
eOrder F for flush device or S for surface device.
fUse 10 AWG maximum size wire for GFI and AFI circuit breakers.
g70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker.
hCU indicates copper bus.
iCopper bus.
jUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
kSupplied with feed-thru lugs.
lFactory-included.
mInterior only, order box separately.
nPK27GTA includes a 6–2/0 AWG Al/Cu lug.
oPE1A Discount Schedule.
New!
QO120L125G
QO816L100F or S
without cover
Table 1.17: Field-Installed Main Circuit Breaker (Use with Convertible Load Centers Only)
QOM1 Frame Size QOM2 Frame Sizes
Main Circuit
Breaker
Ratingp
Convertible
Load Center
Mains Rating
22 k AIRqLug Wire Sizer
AWG/kcmil
Main Circuit
Breaker
Ratingp
Convertible
Load Center
Mains Rating
22 k AIRqLug Wire Sizer
AWG/kcmil
Main Circuit
Breaker $ Price Main Circuit
Breaker $ Price
50 A 100–125 QOM50VH 140.00
12–2/0 Al or Cu
100 A 150–225 QOM2100VH 468.00
4–300 Al or Cu
60 A 100–125 QOM60VH 140.00 125 A 150–225 QOM2125VH 468.00
70 A 100–125 QOM70VH 140.00 150 A 150–225 QOM2150VH 468.00
80 A 100–125 QOM80VH 201.00 175 A 200–225 QOM2175VH 468.00
90 A 100–125 QOM90VH 201.00 200 A 200–225 QOM2200VH 468.00
100 A 100–125 QOM100VH 201.00 225 A 225 QOM2225VH 468.00
110 A 125 QOM110VH 468.00
125 A 125 QOM125VH 468.00
pDo not exceed the load center mains rating.
q22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems
with up to 22 kA available fault current.
rWire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center
per UL, see pages 1-5 through 1-11 under Main Wire Size.
sAdd suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00.
QOM2 Frame Size
100–225 Amperes
QOM1 Frame Size
50–125 Amperes
DE3A PE1A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
1-6 © 2009 Schneider Electric
All Rights Reserved
QO® Load Centers Indoor, 1Ø Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
Main Lug Kits
Table 1.18: Indoor Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL Branch Circuit Breakers
from pages 1-2 and 1-3.)
Mains
Rating Spaces
Max.
Single
Pole
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately) Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page
1-17
Flush
Cat. No. Surface
Cat. No. $ Price
Cat. No. $ Price Cat. No. $ Price
I
N
D
O
O
R
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating,
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5),b
QOM1 Main Circuit Breaker Frame Size—Copper Bus
100 A
12 12 0 339.70 QO112M100 302.00 QOC12UF QOC12US 37.70
6–1
PK9GTA 13.40 5
16 16 0 379.70 QO116M100 342.00 QOC20U100F QOC20U100S 37.70 PK12GTA 15.80 6
20 20 0 433.70 QO120M100 396.00 QOC20U100F QOC20U100S 37.70 PK15GTA 17.10 6
24 24 0 553.70 QO124M100 516.00 QOC24UF QOC24US 37.70 6–2/0 PK15GTA 17.10 7
32 32 0 726.70 QO132M100 689.00 QOC32UF Use Flush 37.70 PK18GTA 18.80 8
125 A 24 24 0 819.70 QO124M125 782.00 QOC24UF QOC24US 37.70 6–2/0 PK15GTA 17.10 7
32 32 0 1041.60 QO132M125 1002.00 QOC32UF Use Flush 39.60 PK18GTA 18.80 8
Convertible Mains —Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 1-5) b
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150 A
20 30 10 821.00 QO12030M150 734.00 QOC30UF QOC30US 87.00
4–250
PK18GTA 18.80 9
24 24 0 849.00 QO124M150 762.00 QOC30UF QOC30US 87.00 PK15GTA 17.10 9
30 30 0 854.00 QO130M150 767.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9
32 32 0 969.00 QO132M150 882.00 QOC40UF QOC40US 87.00 PK18GTA 18.80 10
200 A
20 40 20 821.00 QO12040M200 734.00 QOC30UF QOC30US 87.00
4–250
PK23GTA 21.30 9
24 24 0 866.00 QO124M200 779.00 QOC30UF QOC30US 87.00 PK15GTA 17.10 9
24 36 12 1287.00 QO12436M200TFTh1200.00 QOC40UF QOC40US 87.00 PK23GTA and
LK100ANg10
30 30 0 879.00 QO130M200 792.00 QOC30UF QOC30US 87.00 PK18GTA 18.80 9
30 40 10 957.00 QO13040M200 870.00 QOC30UF QOC30US 87.00 PK23GTA 21.30 9
40 40 0 1121.00 QO140M200 1034.00 QOC40UF QOC40US 87.00 PK23GTA 21.30 10
40 60 20 1431.00 QO14060M200 1344.00 QOC40UF QOC40US 87.00 PK23GTA 21.30 10
42 42 0 1220.00 QO142M200 1109.00 QOC42UF QOC42US 111.00
4–300
PK23GTA 21.30 11
42 52 10 1382.00 QO14252M200 1271.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
225 A 40 40 0 1196.00 QO140M225 1085.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
42 42 0 1253.00 QO142M225 1142.00 QOC42UF QOC42US 111.00 PK23GTA 21.30 11
Fixed Mains—Factory-installed LAL Main Circuit Breaker, 42 kA Short Circuit Current Ratingc
300 A 42 42 0 4909.00 QONQ42MS300
(int)d4243.00 NC62NQVF NC62NQVS 591.00 (1) 4–500
PK27GTAe
or
PK15GTA6
33.80
53.00
16
MH62 (box)f75.00 or (2) 4–3/0
400 A 42 42 0 4909.00 QONQ42MS400
(int)d4243.00 NC62NQVF NC62NQVS 591.00 (1) 4–500 16
MH62 (box)f75.00 or (2) 4–250
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
b22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
cUL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H
circuit breakers only.
dInterior only, order box separately.
ePK27GTA includes a 6–2/0 Al/Cu lug.
fPE1A Discount Schedule.
gFactory included.
hSupplied with feed-thru lugs.
New!
Table 1.19: Field-Installed Main Lugs (Convertible Load Centers Only)
Main Lug
Ratingi
Use on
Convertible Load Center
with Mains Rating Cat. No. $ Price Lug Wire Sizej
AWG/kcmil
Al or Cu
125 A 100–125 A QOL125k 44.10 6–2/0
225 A 150–225 A QOL225k104.00 6–300
iDo not exceed the load center mains rating.
jWire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular
load center per UL, see pages 1-5 through 1-11 under main wire size.
kIf main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from
page 1-13.
QO130M150
QOL125 QOL225
DE3A PE1A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-7
QO® Load Centers Rainproof 1Ø, Main Lugs, Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
1Ø3W—120/240 Vac—UL Listed
1Ø3W—120/240 Vac—UL Listed
Table 1.20: Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 1-2 and 1-3.)
Mains
Rating Spaces Max.
Single Pole
Circuitsa
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately) Box No.
See
Page 1-17
Cat. No. $ Price Al Cu Cat. No. $ Price
R
A
I
N
P
R
O
O
F
Non-Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating
60 A 2 4 2 102.00 QO24L60NRNM 102.00 14–4 14–4 Factory-installed — 1NM
Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10 kA Short Circuit Current Rating
40 A 2 2 0 113.00 QO2L40RBb113.00 12–6 14–6 PK3GTA1 11.40 1R
70 A 2 4 2 131.00 QO24L70RBb131.00 12–3 14–4 PK4GTA 10.80 1R
100 A
612 6 143.00 QO612L100RBc143.00
8–1
PK7GTA 11.70 2R
612 6 158.00 QO612L100TRBc158.00 Factory-installed — 2R
816 8 231.00 QO816L100RBc231.00 PK7GTA 11.70 2R
100 A 612 6 174.00 QO612L100RBCUcd 174.00 8–1 PK7GTA 11.70 2R
816 8 279.00 QO816L100RBCUcd 279.00 PK7GTA 11.70 2R
125 A 4 8 4 152.00 QO148L125GRBd152.00 12–2/0 14–2/0 PK7GTA Factory-included 15R
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
125 A
12 12 0 285.00 QO112L125GRB 285.00
6–2/0
PK9GTA Factory-included 3R
12 24 12 365.00 QO11224L125GRB 365.00 PK15GTA Factory-included 3R
16 24 8 435.00 QO11624L125GRB 435.00 PK15GTA Factory-included 4R
24 24 0 522.00 QO124L125GRB 522.00 PK15GTA Factory-included 4R
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Currentefg
QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
150 A 30 30 0 587.00 QO130L150GRB 587.00 4–250 PK23GTA, LK100AN Factory-included 6R
200 A
12 12 0 480.00 QO112L200GRB 480.00
4–250
PK9GTA Factory-included 5R
30 30 0 666.00 QO130L200GRB 666.00 PK23GTA, LK100AN Factory-included 6R
30 40 10 714.00 QO13040L200GRB 714.00 PK23GTA, LK100AN Factory-included 6R
40 40 0 971.00 QO140L200GRB 971.00 PK23GTA, LK100AN Factory-included 7R
40 60 20 1262.00 QO14060L200GRB 1262.00 (2) PK15GTA, (1) LK100AN Factory-included 7R
42 52 10 1194.00 QO14252L200GRB 1194.00 (2) PK15GTA, (1) LK100AN Factory-included 8R
225 A 42 42 0 1310.00 QO142L225GRB 1310.00 4–300 PK23GTA, LK100AN Factory-included 8R
New!
Table 1.21: Main Circuit Breaker Order QO, QOT, QO-GFI, QO-AFI, QO-EPD and QO-PL branch circuit breakers from pages 1-2 and 1-3.
Mains
Rating Spaces Max.
Single Pole
Circuits a
Max.
Tandem
Circuit
Breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately) Box No.
See
Page 1-17
Cat. No. $ Price Cat. No. $ Price
R
A
I
N
P
R
O
O
F
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
—Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg
QOM1 Main Circuit Breaker Frame Size—Copper Bus
100 A
12 12 0 461.00 QO112M100RB 461.00
6–2/0
PK9GTA 13.40 3R
16 16 0 504.00 QO116M100RB 504.00 PK12GTA 15.80 4R
20 20 0 552.00 QO120M100RB 552.00 PK15GTA 17.10 4R
125 A 24 24 0 954.00 QO124M125RB 954.00 6–2/0 PK15GTA 17.10 4R
Convertible Mains —Factory-installed Main Circuit Breaker, 22 kA Short Circuit Current Rating
—Convertible to Main Lugs (see page 1-6) or Lower Amperage Main Circuit Breaker (see page 1-5)hg
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150 A 20 30 10 953.00 QO12030M150RB 953.00 4–250 PK18GTA 18.80 5R
30 30 0 1122.00 QO130M150RB 1122.00 PK18GTA 18.80 6R
200 A
20 40 20 954.00 QO12040M200RB 954.00
4–250
PK23GTA 21.30 5R
30 30 0 1154.00 QO130M200RB 1154.00 PK18GTA 18.80 6R
30 40 10 1179.00 QO13040M200GRB 1179.00 PK23GTA 21.30 6R
40 40 0 1397.00 QO140M200RB 1397.00 PK23GTA 21.30 7R
40 60 20 1815.00 QO14060M200RB 1815.00 PK15GTA 17.10 7R
42 42 0 1469.00 QO142M200RB 1469.00 PK23GTA 21.30 8R
42 52 10 1718.00 QO14252M200RB 1718.00 PK15GTA 17.10 8R
225 A 42 42 0 1631.00 QO142M225RB 1631.00 4–300 PK23GTA 21.30 8R
QOM1/QOM2 Feed-Thru Main Circuit Breaker With Feed-Thru Lugs—Copper Bus, 22 kA Short Circuit Current Rating h
125 A 6 12 6 620.00 QO1612M125FTRBi620.00 4–2/0 PK12GTA 15.80 3R
150 A 8 16 8 863.00 QO1816M150FTRBi863.00 4–250 PK15GTA-L 35.00 6R
200 A 8 16 8 863.00 QO1816M200FTRBi863.00 4–250 PK15GTA-L 35.00 6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUse 10 AWG maximum size wire for AFI and GFI circuit breaker.
c70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
dCopper bus.
eUL short circuit current rating depends on lowest interrupting rating of circuit breakers installed.
fUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
gSide hinge door device; allow 1-1/4 in. on left side for door to open.
h22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-AFI, QO-EPD and QOPL 10 k AIR branch circuit breakers to permit their application on systems up to 22
kA available fault current.
iQO1612M125FTRB provided with QOM1 frame main circuit breaker. QO1816M150FTRB and QO1816M200FTRB provided with QOM2 frame main circuit breaker.
New!
DE3A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
1-8 © 2009 Schneider Electric
All Rights Reserved
QO® Load Centers 3Ø, Main Lugs, Main Circuit Breaker
Class 1130 / Refer to Catalog 1100CT0501
Table 1.22: 3Ø4W 208Y/120 Vac, 3Ø4W 240/120 Vac Delta and 3Ø3W 240 Vac Delta, UL Listed.
(Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 1-2 and 1-3.)
Mains
Rating
Max.
Number
of 1P QO
circuit
breakers
$ Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately) Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Pages
1-17
Flush
Cat. No. Surface
Cat. No. $ Price
Cat. No. $ Price Al Cu Cat. No. $ Pricej
I
N
D
O
O
R
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Rating a
60 A 3 107.00 QO403L60NF/S 107.00 Cover Included With Load Center (No Door) 10–6 PK4GTA 7.20 13
125 A
12 369.70 QO312L125Gh332.00 QOC16UF QOC16US 37.70i
6–2/0 6–2/0
Factory-incl.g—6
20 508.70 QO320L125Gh471.00 QOC24UF QOC24US 37.70iFactory-incl.g—7
24 577.70 QO324L125Gh540.00 QOC24UF QOC24US 37.70iFactory-incl.g—7
200 A 18 530.00 QO318L200Gh443.00 QOC30UF QOC30US 87.00i6–250 6–250 Factory-incl.f—9
30 707.00 QO330L200Gh620.00 QOC30UF QOC30US 87.00iFactory-incl.f—9
225 A 42 953.00 QO342L225Gh842.00 QOC42UF QOC42US 111.00i6–300 6–300 Factory-incl.f—11
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Rating b
100 A 27 1058.00 QO327M100c971.00 QOC30UF QOC30US 87.00i4–2/0 4–2/0 PK15GTA 17.10 9
125 A 30 1931.00 QO330MQ125dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12
150 A 30 1931.00 QO330MQ150dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12
42 2119.00 QO342MQ150dh 2027.00 QOC342MQF QOC342MQS 92.00 PK23GTA 21.30 12
200 A 30 1931.00 QO330MQ200dh 1839.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK18GTA 18.80 12
42 2119.00 QO342MQ200dh 2027.00 QOC342MQF QOC342MQS 92.00 PK23GTA 21.30 12
225 A 42 2119.00 QO342MQ225dh 2027.00 QOC342MQF QOC342MQS 92.00 4–300 4–300 PK23GTA 21.30 12
R
A
I
N
P
R
O
O
F
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65 kA Short Circuit Current Ratingae
60 A 3 177.00 QO403L60NRB 177.00
Cover Included
—106PK4GTA 10.80 10R
125 A 12 485.00 QO312L125GRB 485.00 6–2/0 6–2/0 Factory Incl.g—3R
20 629.00 QO320L125GRB 629.00 Factory Incl.g—4R
200 A 18 618.00 QO318L200GRB 618.00 6–250 6–250 Factory Incl.f—6R
30 839.00 QO330L200GRB 839.00 Factory Incl.f—6R
225 A 42 1494.00 QO342L225GRB 1494.00 6–300 6–300 Factory Incl.f—8R
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25 kA Short Circuit Current Ratingbe
100 A 27 1185.00 QO327M100RBc1185.00
Cover Included
4–2/0 4–2/0 PK15GTA 17.10 6R
125 A 30 2147.00 QO330MQ125RBd2147.00 4–300 4–300 PK18GTA 18.80 14R
150 A 30 2147.00 QO330MQ150RBd2147.00 4–300 4–300 PK18GTA 18.80 14R
200 A 30 2147.00 QO330MQ200RBd2147.00 4–300 4–300 PK18GTA 18.80 14R
42 2333.00 QO342MQ200RBd2333.00 PK23GTA 21.30 14R
225 A 42 2333.00 QO342MQ225RBd2333.00 4–300 4–300 PK23GTA 21.30 14R
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
aUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b25 kA short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22 kA SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10 k AIR
branch circuit breakers.
cIncludes factory-installed back fed QO3100VH main circuit breaker.
d65 kA Short Circuit Current Rating maximum with field-installed Square D type QGL 65 k AIR minimum main circuit breaker feeding QO and Q1 10 k AIR minimum branch circuit breakers.
eSide hinge door device allow 1-1/4 in. on left side for door to open.
fPK23GTA and LK100AN.
gPK15GTA.
hFor Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating
when QODX...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used).
iDE3A Discount Schedule
jDE2 Discount Schedule
Table 1.23: 3Ø Main Circuit Breakers
Field-installed alternate main circuit breakers for QO 3Ø main circuit breaker load centers rated 70–225 A. Do not exceed the
load center main rating.
Amperage 25 k AIR 65 k AIR 100 k AIRk
70 A QDL32070 QGL32070 QJL32070
80 A QDL32080 QGL32080 QJL32080
90 A QDL32090 QGL32090 QJL32090
100 A QDL32100 QGL32100 QJL32100
110 A QDL32110 QGL32110 QJL32110
125 A QDL32125 QGL32125 QJL32125
150 A QDL32150 QGL32150 QJL32150
175 A QDL32175 QGL32175 QJL32175
200 A QDL32200 QGL32200 QJL32200
225 A QDL32225 QGL32225 QJL32225
$ Price (DE2) 1784.00 2442.00 2796.00
kWhen these 3P circuit breakers are used as the main circuit breaker of a 3Ø load center, the maximum AIR rating
is 65 kA at 240 Vac and 100 kA at 208 Vac.
Table 1.24: 3Ø Main Lug Kits
Field-installed main lugs for convertible 3Ø main circuit breaker load centers.
Main Lug
Amperage Rating Cat. No. $ Price Lug Wire Size
AWG/kcmil
125 A QOL3125 67.00 6–2/0 Cu/Al
225 A QOL3225 158.00 6–300 Cu/Al
QO312L125G
QO342MQ200
DE3 DE3A DE2 Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-9
QO® and Homeline® Load Centers Backup Power Solutions
Class 1130 / Refer to Catalog 1100CT0501
Table 1.25: Order QO, QOT, QO-EPD, QO-GFI, and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.
Mains
Rating
(A) Spaces Max. Single
Pole
Circuits a
Max.
Tandem Circuit
Breakers
Load Center
Box, Interior and Cover Equipment Grounding Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Box No.
See
Page
1-12
Al CuCat. No. $ PriceCat. No. $ Price
Generator Panels for Sub-Feed Applications Type 1 (Indoor)
I
N
D
O
O
R
1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating
30 4 8 4 QO48M30DSGP 563.00
PK7GTA 11.70
14–8 14–8 4
60 4 8 4 QO48M60DSGP 563.00 8–2 8–2 4
Generator Panels with Power Inlet Plug for Sub-Feed Applications Type 3R (Outdoor)
R
A
I
N
P
R
O
O
F
1-Phase 3-Wire 120/240 Vac Factory-Installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating
100
48 4 QO1DM10020TRBR 848.00
Factory-Installed
8–2
48 4 QO1DM10030TRBR 848.00 ——
48 4 QO1DM10050TRBR 1148.00 ——
Generator Panel—Automatic Transfer Switch (Contact your local Square D Field Sales office for more information.) b
I
N
D
O
O
R
1-Phase 3-Wire 120/240 Vac Factory- or Field-Installed Main Circuit Breaker 22,000 RMS Sym. Ampere Short Circuit Current Rating
150 38 42 42 QO13842MX150 1349.00 PK23GTA 21.30 4–250 4–250 12
200 38 42 42 QO13842MX200 1499.00 PK23GTA 21.30 4–250 4–250 12
225 38 42 42 QO13842MX225 1649.00 PK23GTA 21.30 4–250 4–250 12
38 42 42 QO13842UX225 c1199.00 4–250 4–250 12
QOC38MXUF (Cover) 149.00
150 14 28 28 QO11428MX150FTRBde 1349.00 PK23GTA 21.30 4–250 4–250 7R
200 14 28 28 QO11428MX200FTRBde 1499.00 PK23GTA 21.30 4–250 4–250 7R
14 28 28 QO11428UX200FTRBcde 1199.00 PK23GTA 21.30 4–250 4–250 7R
QO Load Center Accessories Cat. No. $ Price Schedule
Manual Transfer Equipment Kit
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that
only one circuit breaker can be “ON’’ at a time. QO2DTI 24.90 DE2E
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual
power supply applications. Can be used with (2) 2P or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers. QO2DTIM 63.00 DE2E
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-
up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LA 102.00 DE3A
Secures two 2P circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-
up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. PK4DTIM4HA 102.00 DE3A
Secures two 2P circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up
power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4DTIM4LAL 102.00 DE3A
Generator Circuit Breaker
Interlock Kit
For use on “G” and “S” Series NEMA 1 and “G”, “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P
main circuit breaker of a load center (100–125 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QOCRBGK1 105.00 DE3A
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main
circuit breaker of a load center (150–225 A) with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QOCGK2 105.00 DE3A
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A)
with a QO 2P (15–125 A) branch circuit breaker. Includes a retaining kit. QORBGK2 105.00 DE3A
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bOne main circuit breaker is included with panel. NEMA 1 indoor device requires cover ordered separately. Alternate source main circuit breaker (QO 125 A max.) ordered separately. Automatic
Transfer Switch and Generator for secondary power source are ordered through a Kohler authorized dealer or contractor.
cUniversal mains – No factory-installed main circuit breaker or main lugs. QOM2 frame size, field-install 22 k AIR. Main circuit breaker or main lugs (see pages 1-5 or 1-6).
dSupplied with feed-thru lugs.
eDevice is rated NEMA 3R and can be used for indoor or outdoor applications.
OFF
ON
OFF
ON
ON
OFF
ON
OFF
135
QO2DTI
PK4DTIM4HA
QO2DTI Installed
QOCGK2 Installed
DE3A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1-10 © 2009 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
QO® Load Centers Special Applications
Class 1130 / Refer to Catalog 1100CT0501
Table 1.26: QO Special Application (Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 1-2 and 1-3.)
Mains
Rating Short Circuit
Current
Rating Spaces Max. 1P
Circuits a
Max. Tandem
Circuit
Breakers
Load Center b
Box, Interior, and Cover Equipment Ground Bar Kit
(Order Separately) Main Wire Size
AWG/kcmil Box No.
See
Page 1-17
Cat. No. $ Price Cat. No. $ Price Al Cu
I
N
D
O
O
R
Manufactured Housing:
1Ø2W 120 Vac—Main Lugs Only—CSA Certified
30 Ac10 kA 2 2
4
0QO2L30TTSd51.00 Factory-installed 12–10 14–10 1
50 A 10 kA 2 2 QO24L50TTSe78.00 —1462
1Ø2W 120 Vac—Main Circuit Breaker—CSA Certified
30 A 10 kA 3 5 2 QO35FM30TTF/S 83.00 Factory-installed f3
1Ø3W 120/240 Vac—Main Lugs Only—CSA Certified
70 A 10 kA 2 4 2 QO24L70TSe78.00
Factory
Installed
12–3 14–4 2
100 A
10 kA 6 12 6 QO612L100TF/Sg86.00
4–1
4
10 kA 6 12 6 QO612L100DTF/Sg101.00 4
10 kA 8 16 8 QO816L100TF/Sg137.00 4
10 kA 8 16 8 QO816L100DTF/Sg159.00 4
Load Center with Cover: 1Ø3W 120/240 Vac—UL Listed Complete QO Load Center—Box, Interior and Combination Cover in One Package
Convertible Mains—Factory-Installed Main Lugs i—QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
125 A
65 kA 12 12
24
20
0QO112L125GC 188.00 PK12GTA Incl. 6–2/0 6
65 kA 12 12 QO11224L125GC 249.00 PK15GTA Incl. 6–2/0 6
65 kA 20 0 QO120L125GC 284.00 PK15GTA Incl. 6–2/0 7
Convertible Mains—Factory-Installed Main Lugs i—QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5)—Copper Bus
150 A 65 kA 30 30 0 QO130L150TC 452.00 PK23GTA, LK100AN Installed 6–250 9
200 A 65 kA 30 40 10 QO13040L200GC 575.00 PK23GTA, LK100AN Incl. 6–250 9
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
100 A
22 kA 12 12 0 QO112M100C 351.00 PK9GTA 13.40 4–1/0 5
22 kA 12 20 8 QO11220M100C 413.00 PK15GTA 17.10 4–1/0 5
22 kA 16 16 0 QO116M100C 395.00 PK12GTA 15.80 4–1/0 6
22 kA 20 20 0 QO120M100C 446.00 PK15GTA 17.10 4–1/0 6
125 A 22 kA 32 32 0 QO132M125C 1041.00 PK18GTA 18.80 6–2/0 8
Convertible Mains—Factory-Installed Main Circuit Breaker—
QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-6) or Lower Amperage Main Circuit Breaker (See page 1-5)—Copper Bus j
150 A 22 kA 20 30 10 QO12030M150C 843.00 PK18GTA 18.80 4–250 9
22 kA 30 30 0 QO130M150C 870.00 PK18GTA 18.80 4–250 9
200 A
22 kA 20 40 20 QO12040M200C 843.00 PK23GTA 21.30 4–250 9
22 kA 30 30 0 QO130M200C 896.00 PK18GTA 18.80 4–250 9
22 kA 30 40 10 QO13040M200C 974.00 PK23GTA 21.30 4–250 9
22 kA 40 40 0 QO140M200C 1137.00 PK23GTA 21.30 4–250 10
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
bOrder F for flush device or S for surface device.
cMains rating 25 A when Al wire is used.
dWill not accept Qwik-Gard® QO-GFI or QO-AFI circuit breaker.
eUse 10 AWG maximum size wire for GFI and AFI circuit breakers.
fMain circuit breaker is a field-installed standard QO single pole circuit breaker. Order separately from page 1-2.
g70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
hUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
iUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
j22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current.
Table 1.27: Auxiliary Gutter
UL Listed for use with standard 1Ø and 3Ø load centers for riser applicationsk. For auxiliary gutter-load center compatibility, see catalog number 1100CT0501
Cat. No. $ Price Cover Conduit Riser Size Width Height Depth
SDAG26 338.00 Flush 1-3/4, 2, 2-1/2 or l3 13.50 26.12 3.75
kOne tap kit required for each riser wire.
lWhen used with B300 bolt-on hubs.
Table 1.28: Tap Kits 120/240 Vac—UL Listed for use with Auxiliary Gutter SDAG26
Cat. N0. $ Price Use with Auxiliary
Gutter Cat. No.
Riser Wire Tap Off Wire
Lug Type Al/Cu Wire Size Lug Type Al/Cu Wire Size
SDGT30020 81.00 SDAG26 Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6–2/0 AWG
SDGT300300 120.00 SDAG26 Mechanical (Included) (2) 6 AWG–300 kcmil Mechanical (Included) (1) 6 AWG–300 kcmil
SDGT300C10C 49.70 SDAG26 Anderson VCEL030516H1
(Not included) (2) 4 AWG–300 kcmil Anderson VCEL02114S1
(Not Included) (1) 8–1/0 AWG
SDGT300C300C 70.00 SDAG26 Anderson VCEL030516H1
(Not included) (2) 4 AWG–300 kcmil Anderson VCEL030516H1
(Not included) (1) 4 AWG–300 kcmil
QOGL20 Grounding Terminals 40.70 SDAG26 Mechanical (Included) (2) 6–2/0 AWG
DE3A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-11
QO® and Homeline® Load Centers Load Center Value Pack
Class 1130, 1170 / Refer to Catalog 1100CT0501
Load Center Value Pack
Riser Panels
Panelboard-style Covers for Riser Panels
Mono-Flat® Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing
solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. Cover NQC30FWG CANNOT be used
when panel has been converted to a main circuit breaker panel. f
Table 1.29: 1Ø3W—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker
Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers
Mains
Rating
Spaces
Max.
1P
Circuitsa
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior, Cover and Branch Circuit Breakers
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Al/Cu
Box No.
See
Pages
1-17
Cat. No. Included Load Center/Circuit Breakers $ Price Cat. No. $ Price
I
N
D
O
O
R
QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 1-2 and 1-3.
Main Circuit Breaker
100 A 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 839.00 PK18GTA 18.80 4–2/0 8
200 A 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 1103.00 PK23GTA 21.30 4–250 9
200 A 30 40 10 QOVP10 (1) QO13040M200C, (10) QO120 1328.00 PK23GTA 21.30 4–250 9
Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14.
Main Lugs
125 A 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 353.00 Included — 6–2/0 6
200 A 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 962.00 Included — 4–250 10
Main Circuit Breaker
100 A 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 528.00 PK15GTA 17.10 4–2/0 7
100 A 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 528.00 PK15GTA 17.10 4–2/0 7
150 A 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 983.00 PK23GTA 21.30 4–250 10
200 A 20 40 20 HOMVP16 (1) HOM2040M200TC, (5) HOM120, (1) HOM230 965.00 Included — 4–250 9
200 A 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 1083.00 Included — 4–250 10
200 A 30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 1083.00 Included — 4–250 10
200 A 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 1328.00 Included — 4–250 10
200 A 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 1328.00 Included — 4–250 10
200 A 40 40 0 HOMVP15 (1) HOM40M200C, (10) HOM120 1346.00 PK23GTA 21.30 4–250 12
R
A
I
N
P
R
O
O
F
Homeline—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 1-14.
Main Circuit Breaker
200 A 20 40 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 1253.00 PK23GTA 21.30 4–250 6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
Table 1.30: 1Ø3W 120/240 Vac—Offset Interior Wide Gutter—30 A Maximum Branch Circuit Breaker on left side of interior bc
Mains
Rating Spaces
Max.
Single
Pole
Circuitsd
Max.
Tandem
Circuit
Breakers
Load Center Box and Interior Load Center Cover Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil Box No.
See
Page 1-17
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Al Cu
I
N
D
O
O
R
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below—Copper Bus
125 A 12 24 12 QO11224L125WG 338.00 QOC20UFWG 53.00 PK15GTA 17.10 6–2/0 14
125 A 20 30 10 QO12030L125WG 465.00 QOC20UFWG 53.00 PK15GTA 17.10 6–2/0 14
Convertible Mains—Factory-installed Main Lugs—65 kA Short Circuit Current Rating
QOM2 Main Frame Size–Convertible to Main Circuit Breaker (See page 1-5) when used with QOC cover below–Copper Bus
200 A 30 40 10 QO13040L200WG 701.00 QOC30UFWG 102.00 PK23GTA 21.30 4–250 23
Convertible Mains—Factory-installed Main Circuit Breaker—22 kA Short Circuit Current Rating
QOM2 Main Frame Size–Convertible to Main Lugs (See page 1-6)—Copper Bus
200 A 24 24 0 QO124M200WG125e683.00 QOC30UFWG 102.00 PK23GTA 21.30 4–250 23
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
bUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
cUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
dMaximum single pole branch circuits utilizing QO and/or QOT circuit breakers.
eComes with 125 A main circuit breaker factory installed.
Mains Rating of Load Center Cat. No. $ Price
125 A NQC20FWG 117.00
200 A NQC30FWG 180.00
fOrder catalog number PK4FL for field-installed lock kit.
DE3A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
1-12 © 2009 Schneider Electric
All Rights Reserved
Load Center Accessories QO Load Center Accessories
Class 1130 / Refer to Catalog 1100CT0501
Table 1.31: QO Load Center Accessories
Description Cat. No. $ Price Schedule
Retaining Kit
Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB,
QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers PK2MB 7.20 DE3A
Secures 3P circuit breaker without accessories to left side of interior when used as a back-fed main. For 3Ø load centers PK3MB 14.70 DE3A
Secures circuit breaker to interior when used as a back-fed main for 2P QO 150–200 A circuit breakers. PK5RK 14.70 DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main.
For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. PK4MB2LA 14.70 DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main.
For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. PK4MB2HA 14.70 DE3A
Miscellaneous
Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers QO1SE 3.60 DE3A
Surge Arresters:
For use on 1Ø3W, 150 Vac maximum SDSA1175 92.00 DE1B
For use on 3Ø4W, 650 Vac maximum SDSA3650 248.00 DE1B
QO Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. QO2175SB 159.00 DE1B
Homeline Surgebreaker CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. HOM2175SB 159.00 DE1B
Surge Arrester
Mounting Kit: UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker
load centers QOSAMK 11.40 DE3A
Replacement Cover
Directory Label: 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5
Circuit Identification
Stickers: Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 DE5
PK3MB
QOSAMK
PK2MB
DE1B DE2E DE3A DE5 Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-13
Load Center Accessories QO® and Homeline® Accessories and Voltage testers
Class 1130, 6610 / Refer to Catalog 1100CT0501
Table 1.32: QO Load Center Accessories
Description Cat. No. $ Price Schedule
Filler Plates
Fills opening in covers if twistout is removed in error QOFP 3.60 DE3A
Fills main circuit breaker opening in convertible load center covers100–125 A QOM1FP 20.30 DE3A
Fills main circuit breaker opening in convertible load center covers150–225 A QOM2FP 20.30 DE3A
Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) KFP 20.30 DE3A
Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Q2FP 20.30 DE3A
Lock Kits
Use with QO612L100DF/S, QO612L100DFCU/SCU, QO612L100DTF/S, QO816L100DF/S, QO816L100DFCU/SCU,
QO816L100DTF/S, QO48M30DSGP, or QO48M60DSGP. PK8FLa98.00 DE3A
Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers PK6FL 93.00 DE3A
Use with 300 and 400 ampere indoor load centers. PK4FL 90.00 PE1A
Neutral / Ground Lugs
Field-installed for 12– 2 Al or 14–4 Cu AWG wire LK70AN 10.10 DE3A
Field-installed for 6–2/0 Al/Cu AWG wire LK100AN 10.80 DE3A
Field-installed for 14–2/0 Al/Cu AWG wire LK125AN 22.10 DE3A
Field-installed for 2–3/0 Al/Cu AWG wire LK150AN 32.40 DE3A
Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 33.20 DE3A
Ground Bar Kits
Standard PK15GTA with a 1–4/0 Al/Cu Lug PK15GTAL 35.00 DE3A
Standard PK18GTA with a 1–4/0 Al/Cu Lug PK18GTAL 37.80 DE3A
Standard PK23GTA with a 1–4/0 Al/Cu Lug PK23GTAL 40.70 DE3A
Insulator Kit for PK7GTA through PK27GTA PKGTAB 43.80 DE3A
Handle Padlock Attachment: For padlocking main circuit breakers in convertible load centers OFF..........50–125 A, QOM1 Frame Size QOM1PA 11.00 DE2E
For padlocking main circuit breakers in convertible load centers OFF..........100–225 A, QOM2 Frame Size QOM2PA 11.00 DE2E
aQO403L60NF/S does not have provisions for a field-installed lock.
PK6FL and PK8FL PK4FL
PKGTAB
QOFP
Table 1.33: Homeline Load Center Accessories
Description Cat. No. $ Price Schedule
Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, “OFF” 50–125 A QOM1PA 11.00 DE2E
100–225 A QOM2PA 11.00 DE2E
Filler Plates
Fills opening in covers if twistout is removed in error HOMFP 3.20 DE3C
Fills main circuit breaker opening in convertible load centers 100–125 A QOM1FP 20.30 DE3A
150–225 A QOM2FP 20.30 DE3A
Neutral Lugs
Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire LK70AN 10.10 DE3B
Field-installed for 6–2/0 AWG Al/Cu wire LK100AN 10.80 DE3B
Field-installed for 14–2/0 AWG Al/Cu wire LK125AN 22.10 DE3B
Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 33.20 DE3A
Miscellaneous
Retaining Kit
Secures circuit breaker to interior when used as a back-fed main.
For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. HOM1RK 6.50 DE3C
Secures ONE circuit breaker right side of interior when used as a back-fed main.
For 100–125 A convertible main load centers, Series S01 and S02 HOM4RK2LA 14.70 DE3C
Secures ONE circuit breaker right side of interior when used as a back-fed main.
For 150–225 A convertible main load centers, Series S01 and S02 HOM4RK2HA 14.70 DE3C
Secures circuit breaker to interior when used as a back-fed main.
For 2P 150–200 A circuit breakers HOM5RK 14.70 DE3C
Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 93.00 DE3A
Replacement Cover
Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL 0.54 DE5
Circuit Identification
Stickers: Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS 0.75 DE5
Generator Circuit
Breaker Interlock Kit
For use on “S” Series NEMA 1 and “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P main
circuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMCRBGK1 105.00 DE3D
For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker
of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMCGK2 105.00 DE3D
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center
(150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMRBGK2 105.00 DE3D
DE2E DE3A DE3B DE3C DE3D DE3E DE5 PE1A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-15
Homeline® Load Centers Indoor, 1Ø, Main Lug, Main Circuit Breaker
Class 1170 / Refer to Catalog 1100CT0501
Table 1.43: 1Ø3W—120/240 Vac—UL Listed—10 kA Short Circuit Current Rating
Mains
Rating Spaces
Max.
Single
Pole
Circuits a
Max.
Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover bMain Wire Size
AWG/kcmil Equipment Ground Bar Kit
(Order Separately) Box No.
See
Page 1-17
Cat. No. $ Price
(DE3C) Al Cu Cat. No. $ Price
(DE3A)
I
N
D
O
O
R
Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 1-14
Factory-installed Fixed Main Lugs
70 A 2 4 2 HOM24L70F/Sdc 59.00 12–3 14–4 PK3GTA1 11.40 2
100 A 6 12 6 HOM612L100F/Sce 78.00 8–1 PK7GTA 11.70 4
125 A 4 8 4 HOM48L125GC 86.00 12–2/0 14–2/0 PK7GTA Factory-included 21
Convertible Mains—Factory-installed Main Lugs
QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16)
125 A
816 8 HOM816L125C 132.00
6–2/0
PK15GTA 17.10 6
816 8 HOM816L125TC 150.00 Factory-installed — 6
12 12 0 HOM12L125C 174.00 PK15GTA 17.10 6
12 24 12 HOM1224L125TC 204.00 Factory-installed — 6
16 24 8 HOM1624L125C 260.00 PK15GTA 17.10 8
20 20 0 HOM20L125C 237.00 PK15GTA 17.10 8
20 24 4 HOM2024L125TC 288.00 Factory-installed — 8
24 24 0 HOM24L125TC 344.00 Factory-installed — 8
Convertible Mains—Factory-installed Main Lugs
QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See page 1-16)
150 A 30 30 0 HOM30L150C 375.00 4–250 PK23GTA 21.30 10
30 30 0 HOM30L150TC 396.00 4–250 Factory-installed — 10
200 A
16 32 16 HOM1632L200TC 357.00
4–250 Factory-installed —
9
16 32 16 HOM1632L200TCFTf575.00 10
20 40 20 HOM2040L200TC 417.00 9
200 A
30 30 0 HOM30L200C 420.00
4–250
PK23GTA 21.30 10
30 30 0 HOM30L200TC 464.00 Factory-installed — 10
30 40 10 HOM3040L200TC 479.00 Factory-installed — 10
40 40 0 HOM40L200C 618.00 PK23GTA 21.30 12
40 40 0 HOM40L200TC 671.00 Factory-installed — 12
40 60 20 HOM4060L200TC 839.00 Factory-installed — 12
42 52 10 HOM4252L200TC 804.00 Factory-installed — 12
225 A 42 42 0 HOM42L225C 732.00 6–250 PK23GTA 21.30 12
Main Circuit Breaker22 kA Short Circuit Current Rating
Convertible Mains—Factory-installed Main Circuit Breaker
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
100 A
816 8 HOM816M100C 315.00 6–1 PK15GTA 17.10 5
816 8HOM816M100TC 333.00 6–1 Factory-installed — 5
12 12 0 HOM12M100C 294.00 6–2/0 PK15GTA 17.10 6
12 24 12 HOM1224M100TC 384.00 6–2/0 Factory-installed — 6
20 20 0 HOM20M100C 396.00 6–1 PK15GTA 17.10 7
24 24 0 HOM24M100C 513.00 6–2/0 PK15GTA 17.10 8
30 30 0 HOM30M100C 672.00 6–2/0 PK23GTA 21.30 10
125 A
12 24 12 HOM1224M125C 606.00
6–2/0
PK15GTA 17.10 6
12 24 12 HOM1224M125TC 620.00 Factory-installed — 6
24 24 0 HOM24M125C 710.00 PK15GTA 17.10 8
30 30 0 HOM30M125C 812.00 PK23GTA 21.30 10
Convertible Mains—Factory-installed Main Circuit Breaker
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 1-16)
150 A
16 32 16 HOM1632M150TC 636.00
4–250
Factory-installed — 9
20 30 10 HOM2030M150TC 750.00 Factory-installed — 9
30 30 0 HOM30M150C 776.00 PK23GTA 21.30 10
200 A
12 24 12 HOM1224M200TC 572.00
4–250
Factory-installed — 9
16 32 16 HOM1632M200TC 675.00 Factory-installed — 9
20 40 20 HOM2040M200C 711.00 PK23GTA 21.30 9
20 40 20 HOM2040M200TC 764.00 Factory-installed — 9
30 30 0 HOM30M200C 798.00 PK23GTA 21.30 10
30 40 10 HOM3040M200TC 891.00 Factory-installed — 10
40 40 0 HOM40M200C 1019.00 PK23GTA 21.30 12
40 60 20 HOM4060M200C 1367.00 PK23GTA 21.30 12
42 42 0 HOM42M200C 1094.00 PK23GTA 21.30 12
42 52 10 HOM4252M200C 1313.00 PK23GTA 21.30 12
225 A 42 42 0 HOM42M225C 1116.00 4–250 PK23GTA 21.30 12
Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs
QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See page 1-16)
200 A
16 32 16 HOM1632U200TC 293.00
4–250
Factory-installed — 9
20 40 20 HOM2040U200TC 357.00 Factory-installed — 9
30 40 10 HOM3040U200TC 530.00 Factory-installed — 10
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
bC at end of catalog number indicates combination flush/surface cover included with device.
cF/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
dHOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
e70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
fSupplied with feed-thru lugs.
New!
New!
DE3A DE3C Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1-16 © 2009 Schneider Electric
All Rights Reserved
www.schneider-electric.us
1LOAD CENTERS
Homeline® Load Centers Rainproof, 1Ø, Main Lug, Main Circuit Breakers
Class 1170 / Refer to Catalog 1100CT0501
Field-Installed Kits
Table 1.44: 1Ø3W 120/240 Vac UL Listed Load Centers
Mains Rating Spaces Max. Single
Pole
Circuits a
Max. Tandem
Circuit
Breakers
Load Center
Box, Interior and Cover Main Wire Size
AWG/kcmil Equipment Ground Bar Kit
(Order Separately) Box No.
See
Page 1-17
Cat. No. (DE3C) $ Price Al Cu Cat. No. (DE3A) $ Price
Main Lugs (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 10 kA Short Circuit Current Rating
R
A
I
N
P
R
O
O
F
Factory-installed Fixed Main Lugs, 10 kA Short Circuit Current Rating
70 A 2 4 2 HOM24L70RBb111.00 12–3 14–4 PK4GTA 10.80 1R
100 A 6 12 6 HOM612L100RBf129.00 8–1 PK7GTA 11.70 2R
125 A 4 8 4 HOM48L125GRB 137.00 12–2/0 14–2/0 PK7GTA Factory-included 15R
Convertible Mains with Factory-installed Main Lugs c, QOM1 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below)
125 A
816 8 HOM816L125RB 248.00
6–2/0
PK15GTA 17.10 3R
12 12 0 HOM12L125RB 234.00 PK15GTA 17.10 3R
12 24 12 HOM1224L125RB 278.00 PK15GTA 17.10 3R
20 20 0 HOM20L125RB 383.00 PK15GTA 17.10 4R
Convertible Mains with Factory-installed Main Lugs c, QOM2 Main Frame Size—Convertible to 22 k AIR Main Circuit Breaker (See Below)
200 A
12 12 0 HOM12L200RB 423.00
4–250
PK23GTA 21.30 5R
20 40 20 HOM2040L200RB 560.00 PK23GTA 21.30 6R
30 30 0 HOM30L200RB 587.00 PK23GTA 21.30 7R
30 40 10 HOM3040L200RB 759.00 ——
40 40 0 HOM40L200RB 911.00 PK23GTA 21.30 14R
40 60 20 HOM4060L200RB 1139.00 PK23GTA 21.30 14R
42 52 10 HOM4252L200RB 1092.00 PK23GTA 21.30 14R
Main Circuit Breaker (Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from Page 1-15), 22 kA Short Circuit Current Rating
Convertible Mains with Factory-Installed Main Circuit Breaker, QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) d
R
A
I
N
P
R
O
O
F
100 A
816 8 HOM816M100RB 429.00 6–1 PK15GTA 17.10 3R
12 12 0 HOM12M100RB 416.00
6–2/0
PK15GTA 17.10 3R
20 20 0 HOM20M100RB 531.00 PK15GTA 17.10 4R
24 24 0 HOM24M100RB 606.00 PK15GTA 17.10 6R
125 A 816 8 HOM816M125RB 716.00 6–2/0 PK15GTA 17.10 3R
24 24 0 HOM24M125RB 858.00 PK15GTA 17.10 6R
Convertible Mains with Factory-installed Main Circuit Breaker, QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
150 A 30 30 0 HOM30M150RB 978.00 4–250 PK23GTA 21.30 7R
200 A
20 40 20 HOM2040M200RB 872.00
4–250
PK23GTA 21.30 6R
30 30 0 HOM30M200RB 1004.00 PK23GTA 21.30 7R
30 40 10 HOM3040M200RB 1152.00 PK23GTA 21.30 7R
40 40 0 HOM40M200RB 1277.00 PK23GTA 21.30 14R
40 60 20 HOM4060M200RB 1596.00 PK23GTA 14.20 14R
42 52 10 HOM4252M200RB 1532.00 PK23GTA 14.20 14R
225 A 16 24 8 HOM1624M225RB 1182.00 4–250 PK15GTA 17.10 7R
42 42 0 HOM42M225RB 1323.00 PK23GTA 21.30 14R
Convertible Mains with Factory-installed Main Circuit Breaker with Feed-thru Lugs c
150 A 8 16 8 HOM816M150FTRB 785.00 4–250 PK15GTAL 35.00 6R
200 Ae816 8 HOM816M200FTRB 785.00 4–250 PK15GTAL 35.00 6R
Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker or Main Lugs c
QOM2 Main Frame Size—Field-install 22 k AIR Main Circuit Breaker or Main Lugs (See Kits Below)
200 A 8 16 8 HOM816U200FTRB 446.00 4–250 PK15GTAL 35.00 6R
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
bHOM-GFI and HOM-AFI branch circuit breakers are limited to number 10 maximum wire.
cSide hinge door device allow 1-1/4 in. on left side for door to open.
d22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current.
eRated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire.
f70 A maximum branch circuit breaker, 100 A maximum back feed main circuit breaker.
New!
New!
Table 1.45: Field-Installed Mains, Convertible Load Centers Only
Field-Installed
Main Type Frame Size Main g
Ampere Rating Use on Convertible Load
Center with Mains Rating Cat. No. $ Price
(DE3A) Lug Wire Sizej
AWG/kcmil
Main Lug h125 A 100–125 A QOL125 44.10 6–2/0 Al or Cu
225 A 150–225 A QOL225 104.00 6–300 Al or Cu
Main Circuit
Breaker i
QOM1
50 A 100–125 A QOM50VH 140.00
12–2/0 Al or Cu
60 A 100–125 A QOM60VH 140.00
70 A 100–125 A QOM70VH 140.00
80 A 100–125 A QOM80VH 201.00
90 A 100–125 A QOM90VH 201.00
100 A 100–125 A QOM100VH 201.00
110 A 125 A QOM110VH 468.00
125 A 125 A QOM125VH 468.00
QOM2k
100 A 150–225 A QOM2100VH 468.00
4–300 Al or Cu
125 A 150–225 A QOM2125VH 468.00
150 A 150–225 A QOM2150VH 468.00
175 A 200–225 A QOM2175VH 468.00
200 A 200–225 A QOM2200VH 468.00
225 A 225 A QOM2225VH 468.00
gDo not exceed the load center mains rating.
hIf main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 1-13.
i22 k AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10 k AIR branch circuit breakers to permit their application on systems with
up to 22 kA available fault current.
jWire range listed for main device kits is the wire range of that device. To find out maximum wire size permitted in a particular load center per UL, see
pages 1-5 through 1-11 under Main Wire Size.
kAdd suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00.
QOL225
Main Lug Kit
QOL125
DE3A DE3C Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
© 2009 Schneider Electric
All Rights Reserved 1-17
QO® and Homeline® Load Centers Indoor Load Centers–Dimensions, Knockouts
Class 1130, 1170 / Refer to Catalog 1100CT0501
Indoor Knockout Information and Enclosure Dimensions
Table 1.46: Enclosure Dimensions
Dimensions Dimensions
Box
No.
WHD
Box
No.
WHD
in. mm in. mm in. mm in. mm in. mm in. mm
1 3.81 97 6.72 171 3.00 76 13 5.88 149 13.12 333 3.38 86
2 4.81 122 9.30 236 3.19 81 14 14.25 362 20.92 531 3.75 95
3 4.81 122 9.30 236 3.19 81 15 20.00 508 50.00 1270 5.75 146
4 8.88 226 12.57 319 3.80 97 16 20.00 508 62.00 1727 5.75 146
5 14.25 362 14.92 379 3.75 95 17 20.00 508 53.00 1346 5.75 146
6 14.25 362 17.92 455 3.75 95 18 5.88 149 16.12 409 3.38 86
7 14.25 362 20.92 531 3.75 95 19 7.56 192 23.12 587 4.25 108
8 14.25 362 26.04 661 3.75 95 20 9.62 244 26.12 663 4.75 121
9 14.25 362 29.86 758 3.75 95 21 8.88 226 14.80 376 3.80 97
10 14.25 362 33.78 858 3.75 95 22 8.55 217 23.92 608 3.95 100
11 14.25 362 37.98 965 3.75 95 23 14.25 362 29.86 758 3.75 95
12 14.25 362 39.37 1000 3.75 95
Table 1.47: Knockout Information
Knockouts
SymbolABCDEFGH I
Conduit
Size 1/23/4 11-1/41-1/222-1/233-1/2
Box 1
A,B,C
A
A
A,B,C
A
A,B,C,D
A,B,C
A
A,B,C
A
Box 2
A
Box 3
A,B
B,C,D,E
B,C,D,E
A
A,B
A
Box 4
B,C,D,E
B,C,D,E
B,C,D,E
B,C,D,E
Box 5
A
B,C,D,E C,D,E,F,G A,B
B,C,D,E
A,B,C,D
A,B
A
C,D,E,F
A,B
A
C,D,E,F
Box 6
B,C,D,E
A,B,C,D
B,C,D,E A
C,D,E,F,G A,B
B,C,D,E A
C,D,E,F,G A,B
A,B
A
C,D,E,F
Box 7
B,C,D,E
A,B,C,D
B,C,D,E A
C,D,E,F,G A,B
Box 8
A,B,C,D
B,C,D,E
C,D,E,F
B,C,D,E
D,E,F,G
B,C,D,E A
C,D,E,F,G A,B
A,B
B,C
A
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
D,E,F,G
Box 9
B,C,D,E A
C,D,E,F,G A,B
D,E,F,G
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
B,C,D,E
D,E,F,G
A,B
B,C
A
Box 10
B,C,D,E A
C,D,E,F,G A,B
D,E,F,G
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
B,C,D,E
D,E,F,G
Box 11
A,B
B,C
A
B,C,D,E A
C,D,E,F,G A,B
C,D,E,F
D,E,F,G
C,D,E,F
B,C,D,E
A,B,C,D
B,C,D,E
D,E,F,G
Box 12
A,B
B,C
A
Box 13
A,B,C,D
C,D,E,F
C,D,E,F
Box 14
A,B
A
B,C,D,E
B,C,D,E
A,B,C,D
A,B,C
AA,B
D,E,F,G
A,B
C,D,E,F
D,E,F,G,H,I
D,E,F,G,H
Box 15, 16, 17
Box 18
A,B,C,D
C,D,E,F
Box 19
D,E,F,G
Box 20
C,D,E,F
D,E,F,G
E,F,G,H
B,C,D,E
B,C,D,E
A
A,B
A
Box 21
B,C,D,E
B,C,D,E
B,C,D,E
B,C,D,E
Box 22
A,B
C,D,E,F
B,C,D,E
D,E,F,G
A,B
B,C
A
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
D,E,F,G
Box 23
A,B,C
AA,B
D,E,F,G
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
www.schneider-electric.us
1LOAD CENTERS
1-18 © 2009 Schneider Electric
All Rights Reserved
QO® and Homeline® Load Centers Rainproof—Dimensions, Knockouts, Bolt-on Hubs
Class 1130, 1170 / Refer to Catalog 1100CT0501
Bolt-On Hubs
Square D equipment with “R’’ or “RB’’ suffix, designated NEMA 3R rainproof construction,
utilizes bolt-on hubs listed below. “RB’’ devices will accept 3/4 in. through 2-1/2 in. bolt-on
hubs without the use of reducers. Off-center conduit thread openings and elongated
mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and
bends. Catalog suffix “R’’ devices require 3 in. through 4 in. field cut opening. Hubs are
suitable for use with conduit having ANSI standard taper pipe thread.
bClosing cap (Cat. No. BCAP) is provided factory-installed on each device having “RB’’ suffix.
Price if ordered separately; $2.50
Table 1.48: Enclosure Dimensions
Dimensions
Box No. WHD
in. mm in. mm in. mm
1NM 6.52 166 8.79 223 3.90 99
1Ra4.88 124 9.38 238 4.00 102
2R 8.88 226 12.65 321 4.27 108
3R 14.75 375 18.92 481 4.52 115
4R 14.75 375 22.06 560 4.52 115
5R 14.75 375 26.04 661 4.52 115
6R 14.75 375 29.86 758 4.52 115
7R 14.75 375 33.78 858 4.52 115
8R 14.75 375 37.98 965 4.52 115
9R 4.56 116 6.50 165 3.88 99
10R 6.92 176 13.18 335 4.12 105
11R 7.56 192 23.24 590 4.75 121
12R 9.62 244 26.24 666 5.50 140
13R 6.92 176 16.18 411 4.12 105
14R 14.75 375 39.37 1000 4.52 115
15R 8.88 226 14.80 376 4.27 108
16R 8.55 217 24.75 629 4.16 106
17R 8.88 226 12.65 321 4.27 108
aHOME250SPA and QO260NATR top endwall has no hub opening.
Table 1.49: Knockout Information
Knockouts
Symbol ABCDEFGH
Conduit Size 1/2 in. 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in.
Table 1.50: Bolt-On Hubs UL Listed for “RB” Devicesb
Conduit Size 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in.
Hub Cat. No. B075 B100 B125 B150 B200 B250
$ Price 33.30 33.30 33.30 33.30 61.35 102.00
Table 1.51: Bolt-On Hubs UL Listed for Mounting in Field-Cut Opening
Conduit Size 3 in. 3-1/2 in. 4 in.
Designed for mounting in field cut opening.
Includes gasket and four mounting bolts and nuts.
Hub Cat. No. B300 B350 B400
$ Price 186.00 300.00 368.00
Box 3R, 4R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1 2" Hub Maximum
C,D,E,F A,B,C
Box 5R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1 2" Hub Maximum
C,D,E,F A,B,C
Box 6R, 7R, 8R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1 2" Hub Maximum
C,D,E,F A,B,C
Box 1NM
A,B B,C
A,B,C,D
A
Box 1R
A,B
2
1 2" Hub Maximum
B,C,D,E
B,C,D,E
A
Box 2R
A,B
2
1 2" Hub Maximum
B,C,D,E
Box 9R
A,B,C
A,B,C,D
C,D,E,F
Box 10R, 13R
B,C,D,E
B,C,D,E
2
1 2" Hub Maximum
D,E,F,G
Box 11R
2
1 2" Hub Maximum
Box 1NM
A,B B,C
“RB’’ Hub
D,E,F,G
Box 12R
2
1 2" Hub Maximum
E,F,G,H E,F
B,C,D,E
B,C,D,E
A
Box 15R
A,B
2
1 2" Hub Maximum
B,C,D,E
Box 16R
A,B
2
1 2" Hub Maximum
C,D,E,F
17R
212"Hub Maximum
B, C, D, E B, C, D, E
B, C, D, E
A
Power lnlet
Box 14R
2
1 2" Hub Maximum
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
C,D,E,F A,B,C
DE1A Discount
Schedule
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Navigation menu