Installation Directions

2014-05-16

: Pdf 45781-Installationsheet 45781-InstallationSheet 078477 Batch3 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

WARNINGS AND CAUTIONS:
ON/OFF LED for remote load status.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult a qualified electrician.
Vizia RF +™ VRCZ4 remote does not control the load, but provides scene applications to operate with Vizia RF +TM dimmers/switches.
Recommended minimum wall box depth is 2-1/2".
WARNINGS AND CAUTIONS:
Can call up four (4) zone ON/OFF with advanced Programmer/Remote (see VRCPG).
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
4-Zone Controller
Cat. No. VRCZ4
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-VRCZ4-00A-X0
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is off
before wiring!
Step 1
Step 3 Preparing and connecting wires:
This 4-Zone controller can be wired using side wire terminal
screws or through backwire openings. Choose appropriate wire
stripping specifications accordingly.
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Side Wire Connection
Side wire terminals accept
#14 AWG solid wire copper only.
5/8"
(1.6 cm) Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Back Wire (either hole may be used)
Back wire openings use #14-12 AWG
solid wire copper only.
WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot wall box wire to terminal screw marked "BK".
Line Neutral wall box wire to terminal screw marked "WH".
Hot (Black)
Neutral (White)
Line
120VAC, 60Hz
BKWH
Green
Ground
4-Zone Controlller
Wiring Application:
Step 4
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble this
configuration, consult a qualified electrician.
Step 2
INTRODUCTION
Leviton’s Vizia RF +TM components are designed to communicate
with each other via Radio Frequency (RF) to provide remote control
of your lighting. Using RF technology allows Leviton to provide the
greatest signal integrity possible. Each module in Leviton’s Vizia RF +TM
component line is a Z-Wave® enabled device. In a Z-Wave® network,
each device is designed to act as a router. These routers will re-transmit
the RF signal from one device to another until the intended device is
reached. This ensures that the signal is received by its intended device
by routing the signal around obstacles and radio dead spots. The 4-Zone
Controller is compatible with any Z-Wave® enabled network, regardless
of the manufacturer and can also be used with other devices displaying
the Z-Wave® logo.
This is a Z-Wave® Controller
Zone/Area control without traveler wires
Can control ON/OFF dim/bright for up to 4 Zones/Area.
ON/OFF LED
Two way communication
RF reliability
Ease of installation – No new wiring
Compatible with other Z-Wave® enabled devices
FEATURES
Tools needed to install your 4-Zone Controller:
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Changing the color of your 4-Zone Controller:
Your 4-Zone controller includes three color options. The controller ships
with the White frame attached. To change color of frame, proceed as
follows:
Line up tabs
and press in
side to attach
Push in
side at tab
to release
After frame is removed, remove existing push buttons by pressing out
buttons from back of frame and replace them with desired color change
push buttons by pressing in from front of frame. To make IR capable, use
new DIM/BRIGHT button with IR window.
INSTALLING YOUR 4-ZONE CONTROLLER
NOTE: Use check boxes when Steps are completed.
Restore power at circuit breaker or fuse.
LED should turn ON, when any button is pressed. If LED does not turn
ON, refer to the TROUBLESHOOTING section.
Position all wires to provide room in
outlet wall box for device.
Ensure that the word “TOP” is facing up
on device strap.
Partially screw in mounting screws in
wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
Testing your 4-Zone Controller prior to mounting
in wall box:
Step 5
2
3
1
1. Line (Hot)
2. Neutral
3. Ground
Step 6 4-Zone Controller Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
NOTES:
If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet.
4-Zone controllers incuded into a Z-Wave® network must be updated
after you have included all other devices.
If using VRCPG install checklist go directly to step B.
A) If using a Leviton Z-Wave® Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System Setup. Press
the center button to select System Setup Menu. Choose Advance
Settings. Press the center button to select Network. Press the center
button to <Include Node>.
B) If using VRCPG Programmer/Remote, you will be prompted to place
4-Zone controller into programming mode.
C) To access Program mode, press and hold the
left side of buttons 1 and 3 (refer to figure).
Wait 5 seconds until the LED turns Amber.
Release the button and the LED will blink
Amber. You are now in Programming mode.
NOTE: If the LED on the 4-Zone controller
turns solid Red while including, there has
been a communication error.
D) While standing close to the 4-Zone controller
(approximately 1 foot), press the center button
on the Programmer/Remote to <Include>
device in the network.
NOTE: Only one device may be included at
any time.
NOTE: If the LED on the 4-scene controller turns solid Red while
including, there has been a communication error.
E) The Primary Programmer/Remote will assign a Home ID, Node ID,
and Name for this device.
NOTE: This information will be stored in the Programmer/Remote to
be used for future reference.
NOTE: You may name or edit the node of this device at this time.
F) The 4-Zone controller is now installed in the network.
Including 4-Zone Controller into Z-Wave®
Network:
Step 8
DI-000-VRCZ4-00A-X0
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,
at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or
implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Step 8 cont'd
Programmer/Remote
Cat. No. VRCPG
NOTE: Programmer/Remote must be
in close proximity to 4-Zone controller
when including in the network.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRF+.com
Protected under U.S. Patent Number 6,388,399 and patents pending and
licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment OFF and ON, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving Antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/tv technician for help.
FCC COMPLIANCE STATEMENT
Including 4-Zone Controller into
Z-Wave® Network:
TROUBLESHOOTING
Locator LED on controller does not turn ON
- Circuit breaker or fuse has tripped.
- If 4-Zone controller is powered up and LED does not turn ON, check
wiring.
Zone Controller does not operate lights
- Check association.
- Ensure that controller was properly updated.
If LED turns solid red
- Check association.
- Ensure that each device in the network is with in 70 ft (21 m) of another
device.
Push Button (Default settings)
Turn ON from OFF position:
Press left side of button – Turns all lights in
Zone/Area ON, LED turns ON.
LED will blink until Zone/Area is ON.
Turn OFF from ON position:
Press right side of button – Turns all lights in
Zone/Area OFF, LED turns OFF.
Dim/Bright:
Press left side of Dim/Bright button - Lights in
last activated Zone/Area will dim.
Press right side of Dim/Bright button - Lights in
last activated Zone/Area will brighten.
NOTE: Controller will only Dim/Bright devices
located within direct Radio Frequency range.
NOTE: LED will be lit Green if any one load in
the associated Area is ON. LED will be OFF
when all loads are turned OFF.
If there is a power outage, when the power is
restored, the lights will return to the last setting
before the power interruption.
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
OPERATION
Locator
LED
Push
Buttons
Dim/Bright
Button
A) If using a Leviton Z-Wave® Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System Setup. Press the
center button to select System Setup Menu. Choose Advance Settings.
Press the center button to select Network. Scroll down to <Exclude
Node> and press the center button.
B) If using VRCPG Programmer/Remote, you will be prompted to place
4-Zone controller into programming mode.
C) To access Program mode, press and hold the left side of buttons 1 and
3 (refer to figure). Wait 5 seconds until the LED turns Amber. Release
the buttons and the LED will blink Amber. You are now in Programming
mode.
NOTE: If the LED on the 4-Zone controller turns solid Red while
excluding, there has been a communication error.
D) While standing close to the 4-Zone controller (approximately 1 foot),
press the center button on the Programmer/Remote to <Exclude>
device in the network.
Factory Default:
If your 4-Zone controller is not responding, or you are unable to control it
after you have tried to Include/Exclude it multiple times, it may be necessary
to reset the 4-Zone controller to its original factory settings. To accomplish
this, proceed as follows:
On the 4-Zone controller (refer to figure), press
and hold the left side of buttons 1 and 3. Wait
approximately 5 seconds until the locator LED turns
Amber and then flashes Red. Release the buttons.
The 4-Zone controller is now reset. Once the
controller is reset, it will be necessary to
Re-Include it to a network before it can be used.
CAUTION: SETTING A DEVICE TO A FACTORY
DEFAULT DOES NOT EXCLUDE THAT DEVICE
FROM A NETWORK. THE EXCLUSION PROCEDURE
MUST STILL BE FOLLOWED TO REMOVE THE
DEVICE FROM THE PRIMARY CONTROLLER’S
INFORMATION TABLE. FAILURE TO DO SO MAY
RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO
RESPOND TO SOME DEVICES.
Excluding 4-Zone Controller from
Z-Wave® Network:
Step 9
After inclusion process, you must associate the devices to the
controllers. Refer to the Primary Programmer/Remote instruction
sheet for complete details.
NOTE: One (1) Z-Wave® device can be associated to multiple controllers
(up to five (5) controllers maximum).
NOTE: If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for associating a device.
Device Association:
Step 10
Programmer/Remote
Cat. No. VRCPG
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Menu
Button
Center
Button
G) After all devices are included into the network, the controller must
be updated to allow proper network function. To update controller
proceed as follows:
If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for updating controller.
If using Leviton Z-Wave® Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System Setup. Press
the center button to select System Setup Menu. Choose Advance
Settings. Press the center button to select Network. Press the
center button to select Update "cntrl". When prompted, press
desired button on 4-Zone controller.
Wait until the VRCPG Programmer/Remote confirms completion.
Update is done.
NOTE: If the 4-Zone controller has been successfully Included in the
network and the user tries to Include it again without first excluding it
from the network, the controller will retain the first node ID it had received
and ignore the second.

Navigation menu