ALARMS & INDICATION
Operator Stations
ST120 Series

Pilla Electrical
Products, Inc.

Description

ALARMS & INDICATION

2

ST120 Series Operator Stations offers a means of disconnect to
shut down equipment and/or initiate alarms during emergency
conditions. Contacts are rated 600V @ 10A AC and 2.5A DC. All
models carry a one-year warranty. UL file is E158147.

ST120-SN4XNM-PO

ST120-FN1-BP2-RPG

ST120SL-RP2-VS

ST120-SN3R-BP2-CS

ST120SL-N1-BS

ORDERING INFORMATION
PUSH-BUTTON OPERATION
MODEL DESCRIPTION
ST120SL Complete push-pull emergency operator station (contacts not included)
Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 4X and 12 nonmetallic surface-mount box
F
Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 4 and 12 all-metal flush-mount box
FN1 Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 1 all-metal flush-mount box
N1 Red maintained 40 mm mushroom (push-pull) labeled “Pull to Reset” NEMA 1 all-metal surface-mount box
RP1 Red “Raised Lid - Push Button” padlockable solid lid over momentary flush round push button
RP2 Red “Raised Lid - Push Button” padlockable solid lid over maintained flush round push button
LEGENDS
BS
EMERGENCY - BOILER SHUT-DOWN
CS
EMERGENCY - CHILLER STOP
FAN
EMERGENCY - EXHAUST FAN
HS
EMERGENCY - HVAC SHUT-DOWN
PO
EMERGENCY - POWER OFF
RPG
EMERGENCY - REFRIGERANT PURGE
SD
EMERGENCY - SHUT DOWN
SO
EMERGENCY - SHUT OFF
ST
EMERGENCY - STOP
VS
EMERGENCY - VENTILATION STOP
VSTART EMERGENCY - VENTILATION START
BREAK-LENS OPERATION
MODEL
ST120

DESCRIPTION
Complete break-lens emergency operator station (spare lens included, contacts not included)
FN1
FN4
SN1
SN3R
SN4
SN4XNM

	
PILCLHCOV1	
PILCLHCOV5	
PILENS	
PILNCCB	
PILNOCB	

NEMA 1 all-metal flush-mount box
NEMA 4 and 12 all-metal flush-mount box
NEMA 1 all-metal surface-mount box
NEMA 3R rainproof all-metal surface-mount box
NEMA 4 and 12 all-metal surface-mount box
NEMA 4X non-metalic surface-mount box
Red “Break Lens to Release Button” model (use normally closed contact to close circuit when button releases)
BP1 Red “Break Lens - Push Button” model, momentary operator
BP2 Red “Break Lens - Push Button” model, maintained operator
“Break Lens - Operate Switch” two-position selector switch, maintained both positions, short lever
P1
P3
“Break Lens - Operate Switch” three-position selector switch, maintained all positions, short lever
LEGENDS - See above

ACCESSORIES	
Clear hinged cover for push-pull model and ST120SN4XNM	
Clear hinged cover for break-lens model except ST120SN4XNM	
Replacement lens for break-lens model	
N.C. stackable contact block for MST1 stations	
N.O. stackable contact block for MST1 Stations	

PAGE
90,92
90-92
90-92

Notes: Six contact blocks max (2 rows of 3) may be used on each break glass operator station and the -FN1 and -N1
modesl of push-button operation stations. The - model and F model push-button stations can only take three contact
blocks (1 row of 3).
All units use normally open contacts to close circuit or normally closed to open circuit (except "Break Glass of Release
Button" model).

90

888-397-5353 USA

kele.com

When you need it right, right now, call Kele.

March
March
20142014



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:04:01 13:26:50-05:00
Metadata Date                   : 2014:04:01 13:27:13-05:00
Modify Date                     : 2014:04:01 13:27:13-05:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:4ff15f00-4b0f-4c41-a2ed-1d404a81d71f
Original Document ID            : xmp.did:01801174072068118F62BC5FC155C38B
Document ID                     : xmp.id:F87F1174072068118C148BDC8D4EBF19
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:204F7499152068118C14C722C0BFAEC1
Derived From Document ID        : xmp.did:FE7F117407206811BD35E84C6D57E38D
Derived From Original Document ID: xmp.did:01801174072068118F62BC5FC155C38B
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2014:04:01 13:26:50-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 1
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu