Product Detail Manual
100046-Attachment 100046-Attachment 100046-Attachment 785901 Batch12 unilog cesco-content
2014-09-27
: Pdf 488193-Attachment 488193-Attachment 785901 Batch8 unilog
Open the PDF directly: View PDF .
Page Count: 60
Download | |
Open PDF In Browser | View PDF |
Table of Contents Section 18 TeSys™ IEC Contactors and Starters Contactors TeSys D 18-4 TeSys D Reversing 18-6 TeSys F 18-5 TeSys D and F Accessories TeSys D Contactors (p. 18-4) 18-8 TeSys K 18-24 TeSys K Accessories 18-27 18-28 GV2, GV3, GV7 Manual Motor Protectors 18-33 Enclosed D-Line 18-21 GV Accessories 18-34 LS1D Fuse Block 18-36 TeSys F Contactors (p. 18-5) Overload Relays TeSys D 18-4 TeSys F 18-5 TeSys D and F Accessories 18-16 TeSys K 18-24 TeSys K Accessories TeSys T Motor Management System 18-27 Section 16 Soft Start Module ATS01 GV7 Manual Motor Starters and Protectors (p. 18-35) 18-32 Replacement Parts TeSys D Coils 18-17 TeSys F Coils 18-20 TeSys F Contact Tips, etc. 18-13 Wiring Systems GV-Line Bus Bars 18-37 TeSys D Quickfit 18-38 AK5 18-39 Dimensions Dimensions GV3P (p.18-33) LUB•2 (p. 18-28) 18-40 GV2P21 (p.18-33) For more information on lighting, definite purpose (DP), and elevator ratings for TeSys D and TeSys F contactors, refer to catalog 8502CT9901. For more information on machine safety applications using TeSys D and TeSys F contactors, refer to catalog MKTED208051EN-US. See our website, www.schneider-electric.us, for UL 508A short circuit ratings (SCCR). © 2012 Schneider Electric All Rights Reserved 18-1 18 TeSys F1700, F2100 TeSys U IEC CONTACTORS AND STARTERS Motor Starters and Protectors 3-Pole Contactors TeSys™ D AC and DC Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.1: TeSys D Contactors—Interpretation of the Catalog Number LC D _____ Full Voltage, Non-Reversing 1 Full Voltage, Reversing 2 _____ _____ _____ _____ TeSys D 3 Pole Contactors, 9–150 A Contactor AC-3 Full Load Amperes (FLA) 18 9 A FLA 12 A FLA 18 A FLA 25 A FLA 32 A FLA 09 12 18 25 32 40 A FLA 50 A FLA 65 A FLA 80 A FLA 40 50 65 80 115 A FLA 150 A FLA 115 150 Everlink Power Connection (40–65 A only) A IEC CONTACTORS AND STARTERS No Everlink Power Connection (9–32 A, 80–150 A) Blank Termination Options (choose one) Screw Termination Spring Terminations s Ring Tongue Terminations t Slip-on Terminations (9–12 A only) Blank 3 6 9 Coil Voltage (choose one) AC Coils (50/60 Hz) DC Coils (standard) 12 V 21 V 24 V 36 V 42 V 12 V 21 V 24 V 36 V 48 V 60 48 V E7 60 V 100 V 110 V 115 V 120 V 127 V 200 V 208 V 220 V 230 V 240 V 277 V 380 V 400 V 415 V 440 V 480 V 500 V 575 V 600 V EE7 K7 F7 FE7 G7 FC7 L7 LE7 M7 P7 U7 W7 Q7 V7 N7 R7 T7 S7 SC7 X7 Y5 (50 Hz only) 660 V s t J7 Z7 B7 C7 D7 72 V 110 V 125 V 220 V 250 V 440 V JD ZD BD CD ED DC Coils low consumption available for 9–38 A only 5V AL 12 V JL 21 V ZL 24 V BL 48 V EL ND 72 V SL SD FD GD MD UD RD 96 V 110 V 220 V 250 V DL FL ML UL For spring terminal versions of LC1D09–LC1D65A, add 3 to the catalog number prior to adding the voltage code (for example, LC1D12G7 becomes LC1D123G7, and LC1D40AG7 becomes LC1D40A3G7. Note that 40–65 A spring terminals are only on the control terminations and not on power terminations). There is no charge for this modification. For ring tongue versions of LC1D09–LC1D65A and LC1DT20–LC1DT80A, add 6 to the catalog number prior to adding the voltage code (for example, LC1D09G7 becomes LC1D096G7, and LC1D50AG7 becomes LC1D50A6G7). There is no charge for this modification. Note: Use this table only to interpret current catalog numbers. Some combinations are not available. 18-2 © 2012 Schneider Electric All Rights Reserved 2, 3, and 4 Pole Contactors TeSys™ F AC and DC Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.2: TeSys F Contactors—Interpretation of the Catalog Number LC _____ Full Voltage, Non-Reversing 1 Full Voltage, Reversing 2 F _____ _____ _____ _____ TeSys F 2, 3, and 4 Pole Contactors 115–800 A Contactor AC-3 Full Load Amperes (FLA) 115 A FLA 150 A FLA 185 A FLA 225 A FLA 265 A FLA 330 A FLA 400 A FLA 500 A FLA 630 A FLA 780 A FLA 800 A FLA 115 150 185 225 265 330 400 500 630 780 800 Number of Poles 2 Poles (400 A, 500 A, and 630 A only) 2 3 Poles (all sizes) 4 Poles (all sizes except 800 A) IEC CONTACTORS AND STARTERS Blank 4 Termination Options—Purchase Lugs Separately Blank Coil Voltage (choose one, noting the contactor size it can be used on) 24 V (50 Hz) 24 V (60 Hz) 24 V (40-400 Hz) 42 V (50 Hz) 48 V (50 Hz) 48 V (60 Hz) 48 V (40-400 Hz) 110 V (50 Hz) 110 V (60 Hz) 110 V 110 V (40-400 Hz) 115 V (50 Hz) 115 V (40-400 Hz) 120 V (60 Hz) 120 V 120 V (40-400 Hz) 120 V (40-400 Hz) 127 V (60 Hz) 127 V (40-400 Hz) 200/208 V (60 Hz) 200/208 V (40-400 Hz) 208 V (40-400 Hz) 220 V (50 Hz) 220 V (60 Hz) 220 V (40-400 Hz) 220 V 230 V (50 Hz) 230 V (40-400 Hz) B5 B6 B7 D5 E5 E6 E7 F5 F6 F7 F7 FE5 FE7 G6 G7 G7 F7 G6 G7 L6 L7 L7 M5 M6 M7 M7 P5 P7 DC Coils 24 V 48 V 110 V 110 V 110 V 125 V 125 V 220 V 250 V 220/240 V 250 V 380/400 V 440 V 440 V © 2012 Schneider Electric All Rights Reserved For use on: AC Coils LC1F115–F225 LC1F115–F225 LC1F225–F400 LC1F115–F225 LC1F115–F225 LC1F115–F225 LC1F115–F630 LC1F115–F225 LC1F115–F225 LC1F1700, F2100 LC1F115–F780 LC1F115–F225 LC1F115–F780 LC1F115–F225 LC1F1700, F2100 LC1F115–F400 LC1F500–F780 LC1F115–F225 LC1F115–F780 LC1F115–F225 LC1F265–F780 LC1F115–F225 LC1F115–F225 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F115–F225 LC1F115–F800 230 V 240 V (50 Hz) 240 V (60 Hz) 240 V (40-400 Hz) 240 V 277 V (50 Hz) 277 V (40-400 Hz) 277 V 380 V (50 Hz) 380 V (60 Hz) 380 V (40-400 Hz) 380 V 400 V (50 Hz) 400 V (40-400 Hz) 400 V 415 V (50 Hz) 415 V (40-400 Hz) 415 V 440 V (50 Hz) 440 V (40-400 Hz) 440 V 460/480 V (60 Hz) 480 V (40-400 Hz) 500 V (50 Hz) 500 V (40-400 Hz) 500 V 600 V (40-400 Hz) 660 V (60 Hz) For use on: P7 U5 U6 U7 U7 W5 W7 W7 Q5 Q6 Q7 Q7 V5 V7 V7 N5 N7 N7 R5 R7 R7 Q6 N7 S5 S7 S7 X7 Y6 LC1F1700, F2100 LC1F115–F225 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F115–F225 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F115–F225 LC1F115–F800 LC1F1700, F2100 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F115–F225 LC1F780 LC1F115–F225 LC1F115–F780 LC1F1700, F2100 LC1F500–F630 LC1F115–F225 18 AC Coils For use on: BD ED FD FD FW GD GD MD UD MW UD QW RD RD LC1F115–F400 LC1F115–F630 LC1F115–F780 LC1F1700, F2100 LC1F800 LC1F115–F780 LC1F1700, F2100 LC1F265–F780 LC1F1700, F2100 LC1F800 LC1F115–F780 LC1F800 LC1F1700, F2100 LC1F115–F780 18-3 Contactors & Overload Relays TeSys™ D Non-reversing Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.3: TeSys D Contactors—3 or 4 Pole, Screw Terminal Connections Maximum Current Utilization Categories Maximum Horsepower Ratings 18 LC1D093 IEC CONTACTORS AND STARTERS LC1D40A Table 18.4: LRD22 LRD3 E164862 CCN NLDX LR43364 Class 3211 04 18-4 Three-Phase TeSys D Overload Relays—Ambient Compensated, Bimetallic, Direct Mounting Class 10 with Class 10 without Single-Phase Single-Phase Sensitivity Sensitivity 0.10–0.16 LRD01 LR3D01 0.16–0.25 LRD02 LR3D02 0.25–0.40 LRD03 LR3D03 0.40–0.63 LRD04 LR3D04 0.63–1 D09–D32 LRD05 LR3D05 1–1.6 LRD06 LR3D06 1.6–2.5 LRD07 LR3D07 2.5–4 LRD08 LR3D08 4–6 LRD10 LR3D10 5.5–8 D09–D32 LRD12 LR3D12 7–10 D09–D32 LRD14 LR3D14 9–13 D12–D32 LRD16 LR3D16 12–18 D18–D32 LRD21 LR3D21 17–24 D25–D32 — — 23–32 D25–D32 LRD32 LR3D32 30–38 D32 LRD35 LR3D35 9-13 D40A-D65A f LRD313 LR3D313 12-18 D40A-D65A f LRD318 LR3D318 16-25 D40A-D65A f LRD325 LR3D325 23-32 D40A-D65A f LRD332 LR3D332 30-40 D40A-D65A f LRD340 LR3D340 37-50 D40A-D65A f LRD350 LR3D350 48-65 D40A-D65A f LRD365 LR3D365 17-25 D40-D80 g LRD3322 LR3D3322 23-32 D40-D80 g LRD3353 LR3D3353 30-40 D40-D80 g LRD3355 LR3D3355 37-50 D50-D80 g LRD3357 LR3D3357 48-65 D50-D80 g LRD3359 LR3D3359 55–70 D65–D80 LRD3361 LR3D3361 63–80 D65–D80 LRD3363 LR3D3363 80–104 D80 LRD3365 — 80–104 D115–D150 LRD4365 — 95–120 D115–D150 LRD4367 — — 110–140 D150 LRD4369 f Overload relays with Everlink termination—direct mount to D40A to D65A only. g Direct mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only. NOTE: For Stand Alone Adapter order LAD7B205. Current Setting Range (A) LC1D115 Instantaneous Auxiliary Contacts $ Price Catalog Number a Inductive Resistive AC3 AC1 N.O. N.C. N.O. N.C. 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp AC Coils DC Coils (A) (A) 94.00 119.00 0.5 1 2 2 5 7.5 9 3 LC1D09 cde 0 — — — — — — — 4 LC1DT20 c 94.00 119.00 20 1 1 — — — — — — — 2 2 LC1D098 c 94.00 119.00 119.00 149.00 1 2 3 3 7.5 10 12 3 LC1D12 cde 0 — — — — — — — 4 LC1DT25 c 25 1 1 119.00 149.00 119.00 149.00 — — — — — — — 2 2 LC1D128 c 1 3 5 5 10 15 18 3 LC1D18 cd 136.00 160.00 0 32 1 1 — — — — — — — 4 LC1DT32 c 149.00 183.00 149.00 183.00 — — — — — — — 2 2 LC1D188 c 2 3 7.5 7.5 15 20 25 3 LC1D25 cd 151.00 181.00 0 40 1 1 — — — — — — — 4 LC1DT40 c 193.00 240.00 193.00 240.00 — — — — — — — 2 2 LC1D258 c 2 5 10 10 20 30 32 50 3 0 1 1 LC1D32 cd 172.00 213.00 3 5 10 10 30 30 40 3 1 1 LC1D40A c 218.00 275.00 60 0 — — — — — — — 4 0 0 LC1DT60Ac 296.00 353.00 3 7.5 15 15 40 40 50 3 LC1D50A c 234.00 291.00 0 1 1 5 10 20 20 40 50 65 80 3 LC1D65A c 322.00 379.00 — — — — — — — 4 0 0 0 LC1DT80Ac 446.00 503.00 7.5 15 25 30 60 60 80 3 1 1 LC1D80 363.00 420.00 0 — — — — — — — 125 4 LC1D80004 b 489.00 524.00 0 0 489.00 524.00 — — — — — — — 2 2 LC1D80008 b — — 30 40 75 100 115 3 LC1D115 479.00 479.00 1 1 — — 40 50 100 125 150 200 3 0 LC1D150 696.00 696.00 — — — — — — — 4 0 0 LC1D115004 630.00 630.00 a Complete the catalog number by adding the coil voltage code from Table 18.11 on page 18-6 (for example, LC1D09G7). b For DC version of these devices, replace the C with a P (for example, LC1D80004•• becomes LP1D80004••). This applies only to 80 A, 4-pole devices. c For ring tongue versions of LC1D09–LC1D65A and LC1DT20–LC1DT80A, add 6 to the catalog number prior to adding the voltage code (for example, LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). There is no charge for this modification. d For spring terminals versions of LC1D09–LC1D65A, add 3 to the catalog number prior to adding the voltage code (for example, LC1D12G7 becomes LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7. Note that 40–65 A spring terminals are only on the control terminations and not on power terminations). Ring tongue terminations have a 10% adder to list price. e For slip-on connector versions of LC1D09 and LC1D12 only, add 9 to the catalog number prior to adding the voltage code (for example, LC1D09G7 becomes LC1D099G7). There is no charge for this modification. Single-Phase LC1D09 No. of Poles For Direct Mounting to LC1... Class 20 with Single-Phase Sensitivity — — — LRD04L LRD05L LRD06L LRD07L LRD08L LRD10L LRD12L LRD14L LRD16L LRD21L LRD22L LRD32L — LRD313L LRD318L LRD325L LRD332L LRD340L LRD350L LRD365L LR2D3522 LR2D3553 LR2D3555 LR2D3557 LR2D3559 LR2D3561 LR2D3563 — — — — Class 20 without Single-Phase Sensitivity — — — LR3D04L LR3D05L LR3D06L LR3D07L LRD08L LRD10L LR3D12L LR3D14L LR3D21L LR3D21L LR3D22L LR3D32L — — — — — — — — LR3D3522 LR3D3553 LR3D3555 LR3D3557 LR3D3559 LR3D3561 LR3D3563 — — — — $ Price 60.00 62.00 73.00 107.00 107.00 127.00 362.00 NOTE: To add ring tongue terminations, add ‘6’ to end of part number. Only devices 0.4 A–32 A. TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 TeSys T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactors & Overload Relays TeSys™ F Non-reversing Refer to Catalog 8502CT9901 www.schneider-electric.us TeSys D Overload Relays—Solid State Current Setting Range (A) 60–100 90–150 Maximum Current 200 V / 208 V 220 V / 240 V 460 V / 480 V 575 V / 600 V AC-3 AC-1 HP HP HP HP A A LC1F115 a Class 20 LR9D5567 LR9D5569 $ Price 298.00 298.00 TeSys F Contactors—2, 3, and 4 Pole Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Catalog Number a Number of Poles $ Price Panel Mounting with Screws 3 LC1F115 479.00 4 LC1F1154 630.00 3 LC1F150 696.00 40 50 100 125 150 250 4 LC1F1504 825.00 3 LC1F185 938.00 50 60 125 150 185 275 4 LC1F1854 1439.00 3 LC1F225 1059.00 Current Rated 225 315 4 LC1F2254 1935.00 3 LC1F265 1179.00 60 75 150 175 265 350 4 LC1F2654 1646.00 3 LC1F330 1621.00 75 100 200 250 330 400 4 LC1F3304 1846.00 2 LC1F4002 1521.00 100 125 250 300 400 500 3 LC1F400 1874.00 4 LC1F4004 2133.00 2 LC1F5002 4324.00 150 200 400 500 500 700 3 LC1F500 4970.00 4 LC1F5004 5617.00 2 LC1F6302 5917.00 250 300 600 800 630 1000 3 LC1F630 6474.00 4 LC1F6304 7582.00 3 LC1F780 7788.00 Current Rated 780 1600 4 LC1F7804 9940.00 — 450 800 900 800 1000 3 LC1F800 6676.00 1700 3 LC1F1700 10,000.00 Current Rated 2100 3 LC1F2100 12,050.00 Complete the part number by adding the coil voltage code from Table 18.8 (for example, LC1F115G7). All contactors except F780 include 1 N.O. coil interlock contact. 30 LC1F1700, F2100 Class 10 LR9D5367 LR9D5369 40 Table 18.7: 75 100 115 200 TeSys F 3-Phase Overload Relays—Solid State, Separate Mounting b Current Setting Range For Direct Mounting to Contactor Class 10 Trip c Class 20 c $ Price A LC1●●●● Catalog Number Catalog Number 30–50 F115–F185 LR9F5357 LR9F5557 298.00 48–80 F115–F185 LR9F5363 LR9F5563 298.00 60–100 F115–F185 LR9F5367 LR9F5567 298.00 90–150 F115–F185 LR9F5369 LR9F5569 298.00 132–220 F185 d –F265 LR9F5371 LR9F5571 298.00 200–330 F265–F500 LR9F7375b LR9F7575b 333.00 300–500 F265–F500 LR9F7379b LR9F7579b 737.00 380–630 F400–F630 LR9F7381b LR9F7581b 905.00 b When mounting overload relays LR9F5●57–LR9F5●71 directly beneath the contactor, supporting the relays with a mounting plate is recommended. With overload relays LR9F7●75–LR9F7●81, use of a support mounting plate is mandatory. c IEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current: Class 10—between 4 and 10 seconds; Class 20—between 6 and 20 seconds. d Interconnection kit LA7F407 is required to mount an LR9F●71 to an LC1F185. Table 18.8: Coil Voltage Codes h Contactor D09–D150 LC1D80–LC1D150 only F115, F150, and F185 F265, and F330 F400— F780 F1700— F2100 Contactor e f g h i j LR43364 Class 3211 04 © 2012 Schneider Electric All Rights Reserved 24 V 50/60 60 50 50 60 40–400 40–400 40–400 Hz 48 V B7 B6 B5 B5 B6 B7 — — 24 V E7 E6 E5 E5 E6 E7 E7 — 48 V 110 V 120 V 208 V 220 V 240 V 440 V 480 V 500 V 600 V F7 F6 F5 F5 F6 F7 F7 F7 110 V AC G7 G6 — — G6 G7 G7 G7 125 V LE7 L6 — — L6 L7 L7 — 220 V M7 M6 M5 e M5 M6 M7 M7 M7 250 V U7 U6 U5 U5 U6 U7 U7 U7 440 V — — — — — — — R7 T7 e T6 — — Q5 S7i N7 — — — — — — — — S7 X7 ef X6 f — — S7 X7 X7 g — DC j D09-D32, DT20-D258 — BL EL FL — ML UL — Low Consumption D09–D150 — BD ED FD GD MD UD RD F115-F330 — BD ED FD GD MD UD RD F400–F780 — — ED FD GD MD UD RD F1700— F2100 — — — FD GD MD UD RD Not available for LC1D80. Not available for LC1D115 or LC1D150. Not available for LC1F780. The 600 V coils for LC1F400–LC1F630 do not include an auxiliary contact for holding circuits. For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901. For use with F265–F330 only. DC coils 3-pole contactors are fitted with built-in surge suppression as standard. Table 18.9: E164862 CCN NLDX Hz Coil Voltage Codes for AC and DC Voltages for F800 (includes built-in surge suppressor) Vac/Vdc 50/60 HZ 110 FW 120 FW 127 FW 220 MW 240 MW 380 QW 415 QW 440 QW TeSys F contactor accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-11 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49 I12 Discount Schedule 18-5 IEC CONTACTORS AND STARTERS Table 18.6: For Direct Mounting Beneath Contactor LC1 D115–D150 D115–D150 18 Table 18.5: Contactors TeSys™ D 3- and 4-Pole Reversing, AC or DC Operating Coil Refer to Catalog 8502CT9901 www.schneider-electric.us Each 3-pole device is prewired with line and load side power wiring for reversing applications. Each 4-pole device is prewired with load side power wiring. Table 18.10: 3-Pole and 4-Pole Mechanically Interlocked Contactors Maximum Horsepower Ratings Built In Auxiliary $ Price No. of N.O. Catalog Contacts Power Number (per contactor) Inductive Resistive AC DC Poles ab AC3 (A) AC1 (A) Control Control 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp N.O. N.C. 0.5 1 2 2 5 7.5 9 3 1 1 LC2D09c 234.00 317.00 20 — — — — — — — 4 1 1 LC2DT20 234.00 317.00 1 2 3 3 7.5 10 12 3 1 1 LC2D12c 317.00 368.00 25 — — — — — — — 4 1 1 LC2DT25 317.00 368.00 1 3 5 5 10 15 18 35 3 1 1 LC2D18c 344.00 400.00 — — — — — — — 32 4 1 1 LC2DT32 419.00 443.00 2 3 7.5 7.5 15 20 25 3 1 1 LC2D25c 374.00 436.00 40 — — — — — — — 4 1 1 LC2DT40 456.00 477.00 2 5 10 10 20 30 32 50 3 1 1 LC2D32c 415.00 503.00 3 5 10 10 30 30 40 60 3 1 1 LC2D40A 565.00 650.00 3 7.5 15 15 40 40 50 70 3 1 1 LC2D50A 596.00 680.00 5 10 20 20 50 50 65 80 3 1 1 LC2D65A 778.00 857.00 7.5 15 30 30 60 60 80 3 1 1 d — 125 — — — — — — — 4 — — d — — — 30 40 75 100 115 3 1 1 LC2D115 e 1165.00 1165.00 200 — — — — — — — 4 — — LC2D115004 e 1391.00 1391.00 — — 40 50 100 125 150 200 3 1 1 LC2D150e 1598.00 1598.00 a Use voltage codes from Table 18.11 to complete the catalog number (for example, LC2D09G7). b Includes mechanical interlock without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by using a N.C. auxiliary contact integrated in the contactor or optional LADN or LAD8N auxiliary contact block. c For LC2D09–LC2D32, electrical interlock can be included by adding a V to the end of the catalog number (for example LC2DO9B7V). List price adder: $5.00. d For these items, order two non-reversing contactors and one mechanical interlock separately. See page 18-4 and 18-14 for selection. e Includes mechanical interlock (LA9D11502) with prewired electrical contacts for interlocking contactor operating coils. Single Phase LC2D09 18 IEC CONTACTORS AND STARTERS Table 18.11: Maximum Current Three Phase Coil Voltage Codes i Contactor Hz D09–D150 50/60 50 60 50 Hz F115, F150, F185 60 Hz F265, F330 40–400 Hz F400–F780 40–400 Hz LC1D80–LC1D150 24 V B7 B5 B6 B5 B6 B7 — 48 V E7 E5 E6 E5 E6 E7 E7 110 V 120 V 125 V 208 V 220 V 240 V 250 V 440 V 480 V 600 V G7 — G6 — G6 G7 F7 AC — — — — — — — DC LE7 — L6 — L6 L7 L7 M7 M5 f M6 M5 M6 M7 M7 U7 U5 U6 U5 U6 U7 U7 — — — — — — — — — — — — — — T7 f — T6 — Q5 S7 j N7 X7 f — X6 gf — SC X7 X7 h — — — RD RD RD — — — — — — F7 F5 F6 F5 F6 F7 F7 D09-D32, DT20-D258 — BL EL FL — — — ML — UL Low Consumption D09–D150 — BD ED FD — GD — MD — UD F115–F330 — BD ED FD — GD — MD — UD F400–F780 — — ED FD — GD — MD — UD f Not available for LC1D80–LC1D150. g Not available for LC1D115 or LC1D150. h Not available for LC1F780. The 600 V coils for LC1F400–LC1F630 do not include an auxiliary contact for holding circuits. i For additional voltage codes refer to the IEC Contactor and Starter catalog, 8502CT9901. j For use with F265–F330 only. Table 18.12: Vac/Vdc 50/60 Hz Coil Voltage Codes for AC and DC Coil Voltages for F800 (includes built-in surge suppressor) 24 — 48 — 110 FW 120 FW 127 FW 208 — 220 MW 240 MW 277 — 380 QW 415 QW 440 QW 480 — 575 — 600 — 660 — TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 E164862 CCN NLDX LR43364 Class 3211 04 18-6 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactors TeSys™ F 3-Pole Reversing, AC or DC Operating Coil Refer to Catalog 8502CT9901 www.schneider-electric.us How to Order: Components are available for customer assembly of TeSys F reversing contactors. For example, the following components must be ordered to build a reversing contactor, 75 hp @ 460 V, with a 120 V / 60 Hz coil: Example of Components Description Contactors Lugs (page 18-12) Auxiliary contacts Power connections Mechanical interlock 3-Pole Contactors Maximum Horsepower Ratings LC1F265 Catalog Number LC1F115G6 DZ2FF1 LADN11 LA9FF976 LA9FF970 Three Phase Maximum Current Inductive AC3 (A) Holding Circuit Contact Built Into Coil Resistive AC1 (A) Catalog Numbera $ Price 230 V 460 V 575 V N.O. N.C. hp hp hp 40 75 100 115 200 1 0 LC1F115 479.00 50 100 125 150 250 1 0 LC1F150 696.00 60 125 150 185 275 1 0 LC1F185 938.00 75 150 200 265 350 1 0 LC1F265 1179.00 100 200 250 330 400 1 0 LC1F330 1621.00 125 250 300 400 500 1 0 LC1F400 1874.00 200 400 500 500 700 1 0 LC1F500 4970.00 300 600 800 630 1000 1 0 LC1F630 6872.00 Current rated 780 1600 0 0 LC1F780 7788.00 — 450 800 900 800 1000 0 0 LC1F800 6676.00 a Use coil voltage codes from the Voltage Codes table on page 18-6 to complete the contactor catalog number. 200 V hp 30 40 50 60 75 100 150 250 Table 18.15: Auxiliary Contact (Electrical Interlocking)—2 must be purchased For use with Number of Contacts Maximum Number of Blocks Per Contactor 1 1 2 2 4 2 LC1F to be ordered separately b 1 — 1 2 2 1 4 — 3 2 Catalog Number — 1 1 2 3 — 4 1 2b $ Price LADN10 LADN01 LADN11 LADN20 LADN22 LADN13 LADN40 LADN04 LADN31 LADC22 13.10 13.10 20.70 20.70 41.50 41.50 41.50 41.50 41.50 41.50 including 1 N.O. + 1 N.C. make-before-break Table 18.16: Accessories—For the Assembly of 3-Pole Reversing Contactors (Horizontal Mounting) With 2 Identical Contactors c c Contact Arrangement Set of Power Connections Catalog Number LC1F115 LA9FF976 LC1F150 LA9F15076 LC1F185 LA9FG976 LC1F265 LA9FH976 LC1F330 LA9FJ976 LC1F400 LA9FJ976 LC1F500 LA9FK976 LC1F630, F800 LA9FL976 For two contactors of different size, refer to pages 18-15. $ Price 106.00 96.00 113.00 151.00 225.00 198.00 306.00 568.00 Horizontal Mounting Mechanical Interlock Kit Catalog Number LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 $ Price 53.00 53.00 53.00 76.00 76.00 76.00 76.00 76.00 TeSys F contactor accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-11 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-42 Table 18.17: E164862 CCN NLDX LR43364 Class 3211 04 © 2012 Schneider Electric All Rights Reserved Definite Purpose Ratings, 3-Phase, Breaking All Lines (Hermetic Refrigeration Compressor) Device FLA LC1D09 (AC coil only) LC1D12 (AC coil only) LC1D18 (AC coil only) LC1D25 (AC coil only) LC1D32 (AC coil only) LC1D40A LC1D50A LC1D65A LC1D80 LC1D95 LC1D115 LC1D150 9 12 18 25 32 40 50 65 75 — 115 150 I12 Discount Schedule LRA 240V 54 72 108 150 192 240 300 390 450 — 690 900 480V 45 60 90 125 160 200 250 325 375 — 575 750 600V 36 48 72 100 128 160 200 260 300 — 460 600 18-7 IEC CONTACTORS AND STARTERS Table 18.14: Quantity 2 6 2 1 1 18 Table 18.13: Contactor Accessories TeSys™ D & F Auxiliary Contacts, Time Delay, Mechanical Latch Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.18: Standard, Instantaneous Auxiliary Contact Blocks Snap-On Mounting Composition Number of Contacts To front of LC● DT20–D258 (4P), LC●D09–D150a or To right side of LC ● F 4a 2 To front of LC ●D80 and D115 or To left side of LC●F 1 To side of LC●D09 to D150 only (not for use on TeSys F) 2 Front Mounted Auxiliary Blocks 18 a b c d IEC CONTACTORS AND STARTERS e Standard Contacts N.O. — 2 1 To front of LP● D40–D80, LC ● DT20–D258 (4P), LC ● D09 to D80 or To right side of — LC ●F f Device supplied with 4 ground terminal points. Table 18.20: 0 1 $ Price LADN22 b LADN13 b LADN40 b LADN04 b LADN31 b LADC22 bc LADN11 b LADN20 b LADN02b 41.50 41.50 41.50 41.50 41.50 41.50 20.70 20.70 20.70 LADN10 d LADN01 d 13.10 13.10 Dust-Tight Contacts N.C. — — 1 N.O. 2 2 2 N.C. — — — — 2 — Catalog Number $ Price LA1DX20 LA1DZ40 LA1DZ31 65.00 82.00 82.00 LA1DY20f 77.00 Catalog Number h $ Price Pneumatic Time Delay Contact Blocks Time Delay Contacts Snap-On Mounting N.O. Type N.C. Range of Time Delay 0.1 to 3 sg LADT0 131.00 0.1 to 30 s LADT2 131.00 10 to 180 s LADT4 131.00 1 to 30 si LADS2 131.00 0.1 to 3 sg LADR0 131.00 On de-energization 1 1 0.1 to 30 s LADR2 131.00 (off-delay) 10 to 180 s LADR4 131.00 Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. For spring terminal versions of these blocks, add a 3 to the end of the catalog number (for example, LADT23). There is no charge for this modification. Switching time between the opening of the N.C. contact and the closing of the N.O. contact: 40 ms ± 15 ms . To front of LP● D40–D80, LC● DT20–D258 (4P), LC ● D09 to D150 or To right side of LC● F i 1 0 Catalog Number a Instantaneous Blocks with Dust-Tight Auxiliary Contacts (IP54) NEMA 12 Snap-On Mounting h N.C. 2 3 0 4 1 2c 1 0 2 1 1 LAD8N11 e 20.70 2 0 LAD8N20 e 20.70 For low consumption coils (LC1D09–D32 only), only one front-mounted two-contact block allowed. No sidemounted contact blocks allowed. For spring terminal versions of these blocks, add a 3 to the end of the catalog number (for example, LADN223). There is no charge for this modification. For slip-on versions, add 9 to the end of the catalog number (for example, LADN229). Including 1 N.O. + 1 N.C. make-before-break overlapping contacts. This block cannot be added to the LC1D 09–D32 contactors; a maximum of 2 blocks can be mounted on the LC1D40A–LC1/LP1D80 contactors only. 1 block may be added to the left side of LC1D09–D32, AC coils only; only 1 block may be added to either side of the LC1D40A–D80 contactors, AC coils only. Cannot be installed on TeSys D contactors with DC coils. Table 18.19: g N.O. 2 1 4 0 3 2c 1 2 0 Table 18.21: 1 On energization (on delay) 1 Mechanical Latch Blocks with Manual or Electrical Unlatch (TeSys D only) Front snap-on mounting onto Catalog Number k Application $ Price For silent operation and LC●D09 to D65A LAD6K10jkl 77.00 energy conservation For silent operation and LC1 D80 to D150 LP1 D80 LA6DK20jk 77.00 energy conservation j Does not include internal coil clearing contact. k Complete the catalog number by adding the coil voltage code (for example, LAD6K10F). l Low consumption DC contactors (and relays) (code coil xL) are not compatible with the LAD6K10x mechanical latching blocks. Table 18.22: E164862 CCN NLDX Coil Voltage Codes for LA6DK Mechanical Latch Blocks Volts 12 24 32/36 42/48 60/72 100 110/ 127 200/ 208 220/ 240 380/ 415 440/ 480 500/ 600 AC or DC J B C E EN K F L M Q R S TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 LR43364 Class 3211 04 18-8 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactor Accessories TeSys™ D Coil Suppressors, Cabling Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us RC Coil Suppressor • • Limitation of transient voltage to 300% of nominal voltage maximum. Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times normal). Table 18.23: Resistor/Capacitor Circuit (RC) for Reduction of Electrical Noise in AC Contactor Coils Installed by LA4DA1U Mounting on Snapping into the cavity on the right side without toolsm Snap-on mounting, and connection without tools to the contactor coil terminals Screw connection to the contactor coil terminals Operating Voltage 50/60 Hz 24–28 V 50–127 V 110–240 V 24-48 V LC1D40A to LC1D65A (3P), 50-127 V LC1DT60A to LC1DT80A 110-240 V (4P) 380-415 V 24–48 V LC●D80 to D150 (3P or 4P) 50–127 V LC●D80 to D115 (4P) 110–240 V 380–415 V Catalog Number LAD4RCE LAD4RCG LAD4RCU LAD4RC3E LAD4RC3G LAD4RC3U LAD4RC3N LA4DA2E LA4DA2G LA4DA2U LA4DA2N LC1D09 to LC1D32 (3P) LC●DT20 to DT40 (4P), $ Price 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 Varistor Coil Suppressor Limitation of transient voltage value to 200% of nominal voltage maximum. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times normal). Table 18.24: Varistor (Peak Limiting) for Reduction of Electrical Noise in AC Contactor Coils Installed by Mounting on Snapping into the cavity on the right side without toolsm Snap-on mounting, and connection without tools to the contactor coil terminals Screw connection to the contactor coil terminals Screw connection to the contactor coil terminals Operating Voltage 50/60 Hz 24–48 V 50–127 V 110–250 V LC1D40A to LC1D65A (3P), 24-48 V LC1DT60A to LC1DT80A 50-127 V (4P) 110-250 V 24–48 Vac LC●D80 to D115 (3P or 4P) 50–127 Vac LC●D12, D25 (4P) 110–250 Vac 24–48 Vdc LC●D80 (3P or 4P) 50–127 Vdc 110–250 Vdc Catalog Number LAD4VE LAD4VG LAD4VU LAD4V3E LAD4V3G LAD4V3U LA4DE2E LA4DE2G LA4DE2U LA4DE3E LA4DE3G LA4DE3U LC●D09 to D32 TeSys D contactors $ Price 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 IEC CONTACTORS AND STARTERS • • Diode Coil Suppressor No overvoltage or oscillating frequency. Polarized component. Increased drop-out time (6–10 times normal). Table 18.25: Diode for Reduction of Electrical Noise in DC Contactor Coils Installed on the upper part by Snap-on mounting and connection w/o tools to the contactor coil terminals LA4DC3U 18 • • Clip-on front mounting Screw connection of wire to the contactor coil terminals Mounting on LC●D09–D32 LC●D40A to D65, D65A to DT80A D80 (3P) D80 (4P) Operating Voltage, DC 24–250 Vdc Catalog Number LAD4DDL $ Price 26.20 24–250 Vdc LAD4D3U 26.20 24–250 Vdc LA4DC3U 26.20 Bidirectional Diode Coil Suppressor • • Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks Table 18.26: Bidirectional Peak Limiting Diode Installed by Mounting on Operating Voltage 50/60 Hz and DC Catalog Number $ Price 24 (AC only) LAD4TB 26.20 72 (AC only) LAD4TS 26.20 12–24 V LAD4T3B 26.20 25–72 V LAD4T3S 26.20 LC1D40A to LC1D65A (3P), Clip-on front mounting and connection without tools LC1DT60A to LC1DT80A 73–125 V LAD4T3G 26.20 to the contactor coil terminals n (4P) 126–250 V LAD4T3U 26.20 251–440 V LAD4T3R 26.20 24 (AC only) LA4DB2B 56.00 72 (AC only) LA4DB2S 26.20 Screw mounting o LC●D80 24 (DC only) LA4DB3B 56.00 72 (DC only) LA4DB3S 56.00 m Installing the suppressor into the cavity makes the electrical connection. Overall width of the contactor remains the same. n For LC●D09–LC●D65A with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as standard. o Mounting at the top of the contactor on coil terminals A1 and A2. D09 to LC●D32 (3P)n Snapping into the cavity on the right side of the contactor m LC●DT20 to DT40 (4P) LAD4T3B Table 18.27: Cabling Accessories Usage Mounting on For adapting existing wiring to a new product or for use with top-mounting accessory. LC1D09 to D38 LC1DT20 to DT60 AC only For adapting existing wiring to a new product or for use with LC1D40A to LC1D65A top-mounting accessory (with no coil suppressor) LAD4BB• • © 2012 Schneider Electric All Rights Reserved Operating Voltage 50/60 Hz Without coil suppression 24-48 V With coil suppression 50-127 V (varistor) 110-250 V — Catalog Number LAD4BB LAD4BBVE LAD4BBVG LAD4BBVU LAD4BB3 $ Price 23.00 23.00 23.00 23.00 26.20 TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 I12 Discount Schedule 18-9 Contactor Accessories TeSys™ D Electronic Timers and Interface Modules Refer to Catalog 8502CT9901 www.schneider-electric.us The following accessories require use of cabling accessories (LAD4BB●●) for proper mounting. See page 18-9 for illustration. Table 18.28: Electronic Serial Timer Modules These solid state modules delay the energizing of the contactor coil, and feature built-in varistor surge suppression. Operational Voltage a Type Catalog Number $ Price 0.1–2 s LA4DT0U On-delay LC1D09–D65A LC1D80–D150 1.5–30 s LA4DT2U 25–500 s LA4DT4U a For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; and ZD for DC. 82. 82. 82. 24–250 Vac 100–250 Vac Time Delay Table 18.29: Interface Modules b These modules allow the contactor coils to be energized from low voltage and low current level signals. They come in mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manually turning the contactor on and off. When a module receives a low level signal, it allows the separate-sourced control voltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays. Interface Type 18 Relay Relay Plus Manual Operation Solid State LA4DFB IEC CONTACTORS AND STARTERS b Operational Voltage 24–250 Vac LC1D09–D150 LC1D09–D150 LC1D09–D150 LC1D09–D150 LC1D09–D65 100–250 Vac — — — — LC1D80–D115 Input Voltage Catalog Number 24 Vdc 48 Vdc 24 Vdc 48 Vdc 24 Vdc LA4DFB LA4DFE LA4DLB LA4DLE LA4DWB $ Price 55. 55. 71. 71. 71. Adapter required for D09–D65A, see table 18.27. Table 18.30: Automatic-Manual-Stop Control Modules These modules allow for local and/or remote operation of the contactor coil. Each module includes a lever to switch from automatic to manual operation and a dial to turn the contactor on and off. Operational Voltage 24–100 Vac LC1D09–D150 18-10 100–250 Vac — I12 Discount Schedule Catalog Number LA4DMK $ Price 35. © 2012 Schneider Electric All Rights Reserved Contactor Accessories TeSys™ D and F Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us For Power Pole or Control Connection For use with contactors LC1/LP1 Sold in lots of Catalog Number D09, D12 D09–D32 1 1 LAD92560 LA9D3260 8.70 12.00 D40A–D65A 1 LAD96560 10.00 D09–D32 D40A–D65A D80 F115 F150, F185 F265, F330, F400 F500 F630, F800 D09–D32 D40A-D65A D80 F115 F150, F185 F265, F330, F400 F500 F630, F800 DT20, DT25 D80 LP1D40–D80 D115, D150 D80 D115, D150 D115, D150 10 1 2 4 4 4 4 4 10 1 1 1 1 1 1 1 2 2 10 10 10 3 1 LA9D2561 LAD9P32 LA9D80961 LA9FF602 LA9FG602 LA9FH602 LA9FK602 LA9FL602 LAD9P3 LAD9P33 LA9D80962 LA9FF601 LA9FG601 LA9FH601 LA9FK601 LA9FL601 LA9D1263 LA9D80963 LA9D09966 LA9D11567 LA9D8067 GV7AC03 LA9D115603 26.20 6.00 6.50 55.00 65.00 169.00 228.00 278.00 10.00 25.00 6.50 6.80 8.20 12.00 21.80 38.20 8.70 17.50 2.20 4.00 5.50 31.10 55.00 For use with contactors LC1/LP1 4-pole contactors D80–D115 D09-D65A, DT20-DT80A, LADN, LADT, LADR For holder LA9D92 Sold in lots of Catalog Number $ Price each 100 LA9D92 .06 Description LA9D3260 LAD92560 Connectors for larger cable sizes 4 poles 3 poles Everlink™ terminal block 3 poles #8 AWG (10 mm2) #4 AWG (25 mm2) 2 poles Links for the parallel connection of: 3 poles (wye-delta shorting strap) LA9D2561 4 poles Second coil connection Control circuit take-off from main pole Spreaders for increasing pole pitch to 45 mm Replacement power terminal block Table 18.32: For Marking Description LA9D80962 Reference label holder snap-on 8 x 22 mm Reference label holder snap-on 8 x 18 mm 3 poles Set of shims for mounting LAD8N and LA8DN Retrofit plate for replacement of LC1D40-D65 with LC1D40A-D65A 35 mm DIN Rail – 2 meters long LA9D11567 .06 LA9D93 4.30 For use with contactors LC1/LP1 D80 Sold in lots of Catalog Number $ Price each 1 LA9D511 9.80 D40A-D65A 1 LAD7X3 25.00 LC1D09 to D80 10 AM1DP200 5.20 $ Price 3 poles 3 poles 4 poles Catalog Number LA5D1158031 LA5D150803 LA5D115804 $ Price 3 poles 3 poles 4 poles Catalog Number LA5D11550 LA5D15050 LA5D115450 Replacement Contacts For use with contactors LC1D115 LC1D150 LC1D115 Three-pole Four-pole Table 18.35: LAD90 1 For Mounting Description Table 18.34: 100 18 Sheet of 300 labels self adhesive 7 x 21 mm Table 18.33: $ Price each 239.00 239.00 318.00 Arc Chambers For use with contactors LC1D115 LC1D150 LC1D115 Three-pole Four-pole 90.00 90.00 119.00 TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F replacement coils and parts . . . . . . . . . pages 18-13, 18-18, 18-20 LA9D511 © 2012 Schneider Electric All Rights Reserved IEC CONTACTORS AND STARTERS Table 18.31: I12 Discount Schedule 18-11 Contactor Accessories TeSys™ F Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.36: LA9D09981 Suppressor Blocks Operating limit: up to 220 V, 50/60 Hz coils Description For Use Catalog Number With coils LX1FF, FG, FH, F115, F150, F185, F225, F265, F330 LA9F980 FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F150, F185, F225, With coils LX1FJ, LA9D09980 F265, F330 Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block LA9D09981 $ Price 21.80 Suppressor block (clip-on mounting to coil) Table 18.37: LA9F980 20.70 5.50 Lugs and Lug Kits a Lug Kit Contactor Cable Size AWG Catalog Number Type LC1 range Contactor Only Overload Relay Directly mounted to contactor Lugs Required Cable size AWG range — — — F115 F150, F185 — F225, F265, F330 F400 F500 DZ2FF6 DZ2FG6 — 14 to 2/0 6 to 3/0 — Line side of Load side of Line side of LC1• contactor overload contactor LR9F5•57 to F5•69 F115 3 each DZ2FF1 3 each DZ2FG1 14 to 2/0 LR9F5•57 to F5•71 F150 to F185 1 each DZ2FG6 6 to 3/0 F225, F265 1 each DZ2FH6 6 to 300 MCM LR9F5•71 Load side of overload 6 to 3/0 DZ2FH6 6 to 300 MCM LR9F7•75 to F7•79 F265 or F330 3 each DZ2FH1 — 4 to 500 MCM DZ2FJ6 DZ2FK6 4 to 500 MCM 2 x 2 to 600 MCM LR9F7•75 to F7•81 F400 LR9F7•75 to F7•81 F500 — 6 to 300 MCM 18 3 each DZ2FJ1 — 4 to 500 MCM 4 to 500 MCM 3 each DZ2FK1 — 2x2 to 600 MCM 4 to 500 MCM 1 each DZ2FL1 F630, F800 DZ2FL6 3 x 2 to 600 MCM LR9F7•81 F630 DZ2FL2 1 each DZ2FR1 3x2 to 600 MCM 4 to 500 MCM DZ2FL3 F780 DZ2FX6 4 x 1/0 to 750 MCM — — — — — — a Lug kits ending in the number 6 include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor will require a different size lug for your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws, washers, and nuts) are provided with the contactors and overload relays, not with the lugs. See Table 18.39 for pricing. IEC CONTACTORS AND STARTERS Table 18.38: Lugs, 2- and 4-Pole c Lug Kit Catalog Number Contactor Type LC1 b c Qty. Required 2-Pole 4 4 4 4 4 b 4 AL/CU Cable Size 4-Pole 8 8 8 8 8 b 8 F115 DZ2FF1 14 to 2/0 F150, F185 DZ2FG1 6 to 3/0 F225, F265, F330 DZ2FH1 6 to 300 MCM F400 DZ2FJ1 4 to 500 MCM F500 DZ2FK1 2 X 2 to 600 MCM F630 DZ2FLb 3 X 2 to 600 MCM F780 DZ2FX1 4 X 1/0 to 750 MCM For 2-pole F630 contactors, order two DZ2FL1 (L1 and T2), and two DZ2FL3 (L2 and T1). For 4-pole F6304, order two DZ2FL1 (L1 and T4), four DZ2FL2 (L2, T2, L3, T3) and two DZ2FL3 (L4 and T1). Lugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one lug. Mounting hardware (screws, washers, nuts) are provided with the contactors, not the lugs. See Table 18.39 for pricing. Table 18.39: Lugs Pricing Lug Catalog Number DZ2FF6 DZ2FG6 DZ2FH6 DZ2FJ6 DZ2FK6 DZ2FL6 DZ2FX6 DZ2FF1 DZ2FG1 $ Price 39.30 65.00 65.00 65.00 131.00 164.00 163.80 6.50 11.00 Lug Catalog Number DZ2FH1 DZ2FJ1 DZ2FK1 DZ2FL1 DZ2FL2 DZ2FL3 DZ2FR1 DZ2FX1 $ Price 11.00 11.00 21.80 27.30 55.00 27.30 173.30 27.30 These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads using DZ2F lug kits. Table 18.40: Power Terminal Protection Shrouds For Use With 2-, 3-, And 4-pole Contactors LA9F70 LC1F115 LC1F150, F185 LC1F225, F265, F330, F400 and F4002, F500 and F5002 LC1F630, F6302 and F800 LC1F1154 LC1F1504 and F1854 LC1F2254, F2654, F3304, F4004, F5004 LC1F6304 Number of Shrouds Per Set 6 6 6 6 8 8 8 8 Catalog Number $ Price LA9F701 LA9F702 LA9F703 LA9F704 LA9F706 LA9F707 LA9F708 LA9F709 42.40 61.00 82.00 93.00 58.00 80.00 111.00 120.00 For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used in place of lugs for power connections. Table 18.41: Insulated Terminal Blocks For contactor type LC1 F115, F150, F185 For overload relay LR9 F5•57, F5•63, F5•67, F5•69 Maximum Cable Size 300 MCM Catalog Number LA9F103 $ Price 55.00 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 18-12 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Replacement Parts TeSys™ F Contact Kits, Arc Chambers Refer to Catalog 8502CT9901 www.schneider-electric.us Replacement Contact Sets a Catalog Number LA5F400802 LA5F500802 LA5F630802 LA5FF431 LA5FG431 LA5FH431 LA5F400803 LA5F500803 LA5F630803 LA5F780801d LA5F800803 LA5FF441 LA5FG441 LA5FH441 LA5F400804 LA5F500804 LA5F630804 LA5F780801d $ Price 717. 1111. 1651. 239. 418. 793. 1076. 1589. 2488. 1651. 2488. 318. 549. 966. 1435. 2461. 3304. 1651. For use on contactors Number of Poles Catalog Number LC1F4002 2 poles LA5F400250 Two-pole LC1F5002 2 poles LA5F500250 LC1F6302 2 poles LA5F630250 LC1F115 3 poles LA5F11550 LC1F150 3 poles LA5F15050 LC1F185 3 poles LA5F18550 LC1F265 3 poles LA5F26550 LC1F330 3 poles LA5F33050 Three-pole LC1F400 3 poles LA5F40050 LC1F500 3 poles LA5F50050 LC1F630 3 poles LA5F63050 LC1F780 1 pole LA5F780150d LC1F800 3 poles LA5F80050 LC1F1154 4 poles LA5F115450 LC1F1504 4 poles LA5F150450 LC1F1854 4 poles LA5F185450 LC1F2654 4 poles LA5F265450 Four-pole LC1F3304 4 poles LA5F330450 LC1F4004 4 poles LA5F400450c LC1F5004 4 poles LA5F500450c LC1F6304 4 poles LA5F630450b LC1F7804 1 pole LA5F780150d Supplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers. Comprises single-pole components. Comprises 2-pole components. 2 identical components per pole are supplied. $ Price 280. 305. 431. 90. 101. 179. 269. 287. 305. 341. 646. 431. 750. 119. 131. 248. 299. 414. 573. 610. 861. 431. Two-pole Three-pole LA5FG431 Four-pole LA5F11550 a b c d NUmber of Poles 2 poles 2 poles 2 poles 3 poles 3 poles 3 poles 3 poles 3 poles 3 poles 1 pole 3 poles 4 poles 4 poles 4 poles 4 poles 4 poles 4 poles 1 pole Arc Chambers TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys F replacement coils and parts . . . . . . . . . pages 18-13, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 Table 18.44: AC and DC Coil Part Numbers for LC1F1700 and LC1F2100 Control Circuit Voltage of the Contactor Voltage Code Spare Coil Part Number Quantity LX1FK065 LX1FK070 LX1FK110 LX1FK110 LX1FK127 LX1FK140 LX1FK200 LX1FK200 LX1FK220 LX1FK220 LX1FK240 2 2 2 2 2 2 2 2 2 2 2 LX4FK055 LX4FK065 LX4FK110 LX4FK125 LX4FK220 2 2 2 2 2 AC Coils 110 V 120 V 220 V 230 V 240 V 277 V 380 V 400 V 415 V 440 V 500 V F7 G7 M7 P7 U7 W7 Q7 V7 N7 R7 S7 110 V 125 V 220 V 250 V 440 V FD GD MD UD RD DC Coils Note: These coills are standard parts included when a voltage code is added to the contactor part number LC1F1700 or LC1F2100. © 2012 Schneider Electric All Rights Reserved I12 Discount Schedule 18-13 IEC CONTACTORS AND STARTERS Table 18.43: For use on contactors LC1F4002 LC1F5002 LC1F6302 LC1F115, F150 LC1F185 LC1F265 LC1F330, F400 LC1F500 LC1F630 LC1F780 LC1F800 LC1F1504, F1154 LC1F1854 LC1F2654 LC1F3304, F400, F4004 LC1F5004 LC1F6304 LC1F7804 18 Table 18.42: Contactors Accessories TeSys™ D Reversing Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.45: Contactors Reversing contactors comprising two identical, horizontally mounted contactors: Mechanical interlock Without electrical interlock Catalog Number Set of power connections With incorporated electrical interlock (2 N.C. contacts) $ Price Catalog Number 32.10 Reversing contactors for motor control $ Price Catalog Number LAD9R1a LC1DT20, LC1DT25, LC1DT32, LC1DT40 LADT9R1a 36.90 LADT9R1Va 45.50 a Kit including mechanical interlock and wiring. LAD9R1Va 45.50 LC1D40, LC1D50, LC1D/LP1D65 LA9D50978 LC1D40A, D50A, D65A LAD4CM 45.00 — LAD9R3 b 65.00 — b Kit combines both LAD4CM and LA9D65A69 $ Price Catalog Number $ Price Included with kit — — Included with kit 18 LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 Four pole contactors IEC CONTACTORS AND STARTERS 31.70 LA9D4002 45.90 LA9D6569 53.00 LA9D65A69 75.00 LA9D6570 63.00 — — — LC1D80 AC coil LA9D50978 31.70 LA9D4002 45.90 LA9D8069 65.00 LA9D8070 79.00 LC1D80 DC coil LA9D80978 31.70 LA9D8002 65.00 LA9D8069 65.00 LA9D8070 79.00 LA9D11502 78.00 LA9D11569 129.00 LA9D11571 (3P) LA9D11570 (4P) (D115 only) 53.00 LC1D115 and LC1D150 Not Available — 53.00 TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-14 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactor Accessories TeSys™ F Reversing Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us With 2 Identical Contactors a Set of Power Connections Catalog Number Horizontal Mounting LC1F115 LC1F150 LC1F185 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 or F800 LA9FF976 LA9F15076 LA9FG976 LA9FH976 LA9FJ976 LA9FJ976 LA9FK976 LA9FL976 Vertical Mounting LC1F115 or F150 LC1F185 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 or F800 LC1F780 LA9F•976 Table 18.47: d d d d d d d b Horizontal Mounting LC1F115/4 LC1F150/4 LC1F185/4 LC1F265/4 LC1F330/4 LC1F400/4 LC1F500/4 LC1F630/4 Vertical Mounting LC1F115/4 LC1F185/4 LC1F265/4 LC1F330/4 LC1F400/4 LC1F500/4 LC1F630/4 LC1F780/4 Table 18.48: Upper Contactor LA9FX970 L1 L2 L3 A1 A2 A1 1 3 5 1 3 5 2 4 6 2 4 6 U V A2 W Reversing (motors) Application A1 A2 1L1 2L1 2L3 2L2 2N 1 3 5 7 1 3 5 7 2 4 6 8 2 4 6 8 A1 A2 LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 53.00 53.00 53.00 76.00 76.00 76.00 76.00 76.00 LA9FF4F LA9FG4G LA9FH4H LA9FJ4J LA9FJ4J LA9FK4K LA9FL4L LA9FX970 b 97.00 113.00 126.00 149.00 149.00 149.00 149.00 508.00 Three-Pole Four-Pole LA9FF982 LA9F15082 LA9FG982 LA9FH982 LA9FJ982 LA9FJ982 LA9FK982 LA9FL982 LA9FF977 LA9F15077 LA9FG977 LA9FH977 LA9FJ977 LA9FJ977 LA9FK977 LA9FL977 d d d d d d d b d d d d d d d c Mechanical Interlock Kit Catalog Number $ Price 53.00 53.00 53.00 83.00 113.00 113.00 154.00 233.00 — — — — — — — — $ Price LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 53.00 53.00 53.00 76.00 76.00 76.00 76.00 76.00 LA9FF4F LA9FG4G LA9FH4H LA9FJ4J LA9FJ4J LA9FK4K LA9FL4L LA9FX970 c 97.00 113.00 149.00 149.00 149.00 149.00 149.00 508.00 Vertical Mounting of 2 Contactors of Different Ratings a Lower Contactor e LC1F185 or 1854 LC1F265 or 2654 LC1F330 or 3304 1L2 — — — — — — — — $ Price Component Parts for the Assembly of TeSys F 3-pole or 4-pole Transfer Contactors Horizontal Mounting LA9F•4• 1L3 106.00 96.00 113.00 151.00 225.00 225.00 306.00 568.00 Set of Power Connections LA9F•977 1N Mechanical Interlock Kit Catalog Number $ Price Mechanical Interlock Kit Catalog Number LA9FG4F LA9FH4F LA9FH4G LA9FJ4F LA9FJ4G LA9FJ4H LA9FK4F LA9FK4G LA9FK4H LA9FK4J LA9FL4F LA9FL4G LA9FL4H LA9FL4J LA9FL4K LC1F115/150 or 1154/1504 LC1F115/150 or 1154/1504 LC1F185/1854 or 265/265A LC1F115/150 or 1154/1504 LC1F400 or 4004 LC1F185 or 1854 LC1F265/2654 or 330/330A LC1F115/150 or 1154/1504 LC1F185 or 1854 LC1F500 or 5004 LC1F265/2654 or 330/330A LC1F400 or 4004 LC1F115/150 or 1154/1504 LC1F185 or 1854 LC1F630, 6304 or LC1F265/2654 or 330/330A LC1F800 LC1F400 or 4004 LC1F500 or 5004 a With identical or different numbers of poles. b Double mechanical interlock with 2 mechanical links and 3 power connection bars. c Double mechanical interlock with 2 mechanical links and 4 power connection bars. d Power connection to be assembled by the customer, except for contactors LC1F780 and F7804. e Lower contactor must have equal or lower current rating. $ Price 113.00 126.00 126.00 126.00 126.00 149.00 149.00 126.00 149.00 149.00 116.00 126.00 149.00 149.00 149.00 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . . . . . .pages 18-18 to 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-42 to 18-47 L1 L2 L3 N Transfer/Changeover Applications © 2012 Schneider Electric All Rights Reserved I12 Discount Schedule 18-15 IEC CONTACTORS AND STARTERS LA9F•970 Component Parts for the Assembly of F-Line 3-pole Reversing Contactors 18 Table 18.46: Overload Relays TeSys™ D and F Overload Relay Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us TeSys D Overload Relay Accessories Table 18.49: Mounting Kits and Platesa Description LA7D901 For use with overload relays: LRD01–35 and LR3D01–35 LRD01–35 and LRD01–35 for ring tongue terminals Separate mounting kits for mounting to 35 mm DIN rail LRD15•• or for panel mounting with screws LR2D15••, LR3D15 LR2D25•• LRD3•••, LR3D3•••, LR2D35•• LRD01–35, LR3D01–35, LR2D15•• Mounting plates for screw mounting LR2D25•• at 110 mm (4.3 in.) centers LRD3•••, LR3D3••, LR2D35•• a When using mounting plates, separate mounting kits are also required. Table 18.50: Catalog Number LAD7B10 LAD7B106 LAD7B105 LA7D1064 LA7D2064 LA7D3064 DX1AP25 DX1AP26 LA7D902 Accessories Description Standard Packaging 10 10 10 1 1 1 For use with 18 Prewiring kit allows direct connection of the N.C. contact LC1D09 through D18 of relay LRD01–D32 or LR3D01–D32 to the contactor LC1D25, D32 Stop button locking device All relays except LRD01–D32, LR3D01–D32 and LR9D LRD01-D32, LRD3, LR3D01-D32, LR3D3 Remote stop/tripping or electrical resetc All relays except LRD01–D32, LR3D01–D31 Reset by flexible cable 500 mm (19.6 in.) LRD01-D32, LRD3, LR3D3 b Part number to be completed by adding coil voltage code, (for example, LAD703F). Table 18.51: IEC CONTACTORS AND STARTERS LA7D03 c d $ Price 8.70 8.70 10.40 8.70 13.10 17.50 11.00 12.00 16.40 Catalog Number $ Price LAD7C1 LAD7C2 LA7D901 LAD703b LA7D03b LAD7305 8.70 8.70 2.20 43.70 43.70 100.00 Control Circuit Voltages for LA7D03 and LAD703 Volts 12 24 48 110 220/230 380/400 415/440 AC 50/60 Hz Jd B E F M Q N DC J B E F M — — The time that the LA7D03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s rest time; maximum pulse duration of 20 s with rest time of 300 s. Consumption on inrush and sealed: < 100 VA Not available for LRD01–D32, LR3D01–D32. TeSys F Overload Relay Accessories Table 18.52: Mounting Plate for Overload Relay For use with relays LR9F5•57, F5•63, F5•67, F5•69 and F5•71 LR9F7•75, F7•79 and F7•81 Catalog Number LA7F901 LA7F902 $ Price 27.30 38.20 LA7F90• These clear plastic protective shrouds are an effective means to meet international finger-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits. Table 18.53: Power Terminal Protection Shrouds, Single-Pole For use with relays LR9F5•57 LR9F5•63, F5 67, F5•69 LR9F5•71 LR9F7•75, F7•79, F7•81 t Table 18.54: LA9F70• For relays LR9F5•57, F5•63, F5•67, F5•69 LR9F5•57, F5 63 LR9F5•71 LR9F7•75, F7 •• 79 LR9F7•81 LR9F7•75, F7•79, F7•81 LR9F7•81 e Mounting plate required. t Table 18.56: Catalog Number LA7F701 LA7F702 LA7F703 $ Price 27.30 38.20 49.20 Connection Accessories (for Mounting Overload Relays Beneath Reversing Contactors)e Application LA7F701 $ Price 42.40 61.00 86.00 82.00 Power Terminal Protection Shrouds, 3-Pole For use with relays LR9F5•57, F5•63, F5•67, F5•69 LR9F5•71 LR9F7•75, F7•79, F7•81 Table 18.55: Catalog Number LA9F701 LA9F702 LA9F705 LA9F703 For contactor LC1F115 LC1F150 and F185 LC1F265 LC1F265...F400 LC1F400 LC1F500 LC1F630 Set of 3 Bars Catalog Number LA7F401 LA7F402 LA7F403 LA7F404 LA7F404 LA7F405 LA7F406 $ Price 19.70 21.80 27.30 30.50 30.50 38.20 43.70 Marking Accessories Description Marker holder, snap-in Sold in units of: 100 Catalog Number LA7D903 $ Price 0.03 each Main overload selection . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-45 to 18-47 TeSys T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91 18-16 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactor Repair Parts TeSys™ D and Old D2 AC Coils Refer to Catalog 8502CT9901 www.schneider-electric.us Rated Nominal Voltage LX1D2 Catalog Number 50/60 Hz 12 21a 24 32 36 42 48 60 100 110 115 120 127 200 208 220/230 230 230/240 277 380/400 400 415 440 480 575 600 LXD1J7 LXD1Z7 LXD1B7 LXD1C7 LXD1CC7 LXD1D7 LXD1E7 LXD1EE7 LXD1K7 LXD1F7 LXD1FE7 LXD1G7 LXD1FC7 LXD1L7 LXD1LE7 LXD1M7 LXD1P7 LXD1U7 LXD1W7 LXD1Q7 LXD1V7 LXD1N7 LXD1R7 LXD1T7 LXD1SC7 LXD1X7 Specifications Average consumption - Inrush (inductance 0.75) - Sealed (inductance 0.3) $ Price For LC1D09, D12, D18—For old D2 style contactors where the catalog number includes the auxiliary contact arrangement Rated Nominal Voltage V 26.20 26.20 26.20 26.20 26.20 26.20 50/60 Hz 70 VA 7 VA 80–110% of nominal @ 50 Hz, oC Operating range@ 60 85–110% of nominal @ 60 Hz a Voltage for special coils fitted in contactors with serial timer modules, with 24 V supply. Table 18.59: Table 18.58: 21 b 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Specifications R Catalog Number 50 Hz LX1D2Z5 LX1D2B5 LX1D2C5 LX1D2D5 LX1D2E5 LX1D2F5 — LX1D2G5 — LX1D2M5 LX1D2P5 LX1D2U5 LX1D2W5 — LX1D2Q5 LX1D2V5 LX1D2N5 LX1D2R5 — LX1D2S5 — — LX1D2Y5 50 Hz Catalog Number 60 Hz LX1D2Z6 LX1D2B6 — — LX1D2E6 LX1D2F6 LX1D2G6 — LX1D2L6 LX1D2M6 — LX1D2U6 — LX1D2W6 LX1D2Q6 — — LX1D2R6 LX1D2T6 — LX1D2S6 LX1D2X6 — 60 Hz Catalog Number $ Price 50/60 Hz LX1D2Z7 LX1D2B7 — 52.40 LX1D2D7 LX1D2E7 LX1D2F7 LX1D2G7 — 52.40 — LX1D2M7 LX1D2P7 LX1D2U7 — 52.40 — LX1D2Q7 LX1D2V7 LX1D2N7 LX1D2R7 52.40 — — — — 52.40 — 50/60 Hz 60 VA 70 VA 70 VA at 50 or 60 Hz ts c u d k o oc Pr t S ys d ite TeS m Li by ed c la p e Average consumption Inrush (inductance .75) Sealed 7 VA 7.5 VA (inductance .3) Operating range 80–110 % of 80–110% of at 55oC / 131oF nominal voltage nominal voltage 8 VA at 50 or 60 Hz 85–110% of nominal voltage For LC1D25, D32—For old D2 style contactors where the catalog number includes the auxiliary contact arrangement Rated Nominal Voltage (V) 21b 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Catalog Number 50 Hz Catalog Number 60 Hz Catalog Number 50/60 Hz LX1D4Z5 LX1D4B5 LX1D4C5 LX1D4D5 LX1D4E5 LX1D4F5 — LX1D4G5 — LX1D4M5 LX1D4P5 LX1D4U5 LX1D4W5 — LX1D4Q5 LX1D4V5 LX1D4N5 LX1D4R5 — LX1D4S5 — — LX1D4Y5 LX1D4Z6 LX1D4B6 — — LX1D4E6 LX1D4F6 LX1D4G6 — LX1D4L6 LX1D4M6 — LX1D4U6 — LX1D4W6 LX1D4Q6 — — LX1D4R6 LX1D4T6 — LX1D4S6 LX1D4X6 — LX1D4Z7 LX1D4B7 — LX1D4D7 LX1D4E7 LX1D4F7 LX1D4G7 — — LX1D4M7 LX1D4P7 LX1D4U7 — — LX1D4Q7 LX1D4V7 LX1D4N7 LX1D4R7 — — — — — ct u k od c r o St s P d y ite TeS m Li by ed c la p Re s $ Price 72.00 72.00 72.00 72.00 72.00 Specifications 50 Hz 60 Hz Average consumption - Inrush (inductance .75) 90 VA 100 VA - Sealed (inductance .3) 7.5 VA 8.5 VA 80–110% of 80–110% of Operating range nominal voltage nominal voltage at 55 °C / 131 °F b For use in 24 V applications involving serial timer modules refer to page 18-10. 50/60 Hz 100 VA at 50 or 60 Hz 8.5 VA at 50 or 60 Hz 85–110% of nominal voltage TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 © 2012 Schneider Electric All Rights Reserved I12 Discount Schedule 18-17 IEC CONTACTORS AND STARTERS For LC1D09–D32, LC1DT20–40 (TeSys D) Contactors and CAD Relays 18 Table 18.57: Contactor Repair Parts TeSys™ D, Old D2, and F AC Coils Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.60: 18 IEC CONTACTORS AND STARTERS Rated Nominal Voltage V 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 For Old D2 Style LC1D40, D50, D65, D80 Catalog Number 50 Hz LX1D6B5 LX1D6C5 LX1D6D5 LX1D6E5 LX1D6F5 — LX1D6G5 — LX1D6M5 LX1D6P5 LX1D6U5 LX1D6W5 — LX1D6Q5 LX1D6V5 LX1D6N5 LX1D6R5 — LX1D6S5 — — LX1D6Y5 Catalog Number 60 Hz LX1D6B6 — — LX1D6E6 LX1D6F6 LX1D6G6 — LX1D6L6 LX1D6M6 — LX1D6U6 — LX1D6W6 LX1D6Q6 — — LX1D6R6 LX1D6T6 — LX1D6S6 LX1D6X6 — Catalog Number 50/60 Hz LX1D6B7 — LX1D6D7 LX1D6E7 LX1D6F7 LX1D6G7 — LX1D6LE7 LX1D6M7 LX1D6P7 LX1D6U7 — — LX1D6Q7 LX1D6V7 LX1D6N7 LX1D6R7 — — — — — Table 18.61: $ Price 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 170.00 41.50 41.50 41.50 41.50 41.50 41.50 170.00 41.50 41.50 41.50 For old style and new TeSys style contactors where the catalog number may or may not include the auxiliary contact arrangement. Specification Average consumption: -inrush (inductance 0.75) -sealed (inductance 0.3) Operating range at 55oC / 131oF 50 Hz 60 Hz 200 VA 220 VA 20 VA 22 VA 80–110% of nominal voltage 50/60 Hz 245 VA 26 VA 85–110% of nominal voltage Table 18.63: Rated Nominal Voltage V 12 24 32 42 48 100 110 115 120 127 200 208 220 230 240 277 380 400 415 440 480 500 575 600 660 690 For TeSys D LC1D40A, D50A, D65A, DT60A, DT80A Catalog Number 50 Hz LXD3J5 — — — — — — — — — — — — — — — — — — — — — — — — — Specification Average consumption: -inrush (inductance 0.3) -sealed (inductance 0.3) Operating range at 55 °C / 131 °F Catalog Number 60 Hz — — — — — — — — — — — — — — — — — — — — — — — — — — 50 Hz Catalog Number 50/60 Hz — LXD3B7 LXD3C7 LXD3D7 LXD3E7 LXD3K7 LXD3F7 LXD3FE7 LXD3G7 LXD3FC7 LXD3L7 LXD3LE7 LXD3M7 LXD3P7 LXD3U7 LXD3W7 LXD3Q7 LXD3V7 LXD3N7 LXD3R7 LXD3T7 LXD3S7 LXD3SC7 LXD3X7 LXD3YC7 LXD3Y7 60 Hz 160 VA 140 VA 7.0 VA 7.5 VA 85–110% of nominal voltage Table 18.62: Rated Nominal Voltage V 24 32 42 48 110 115 120 127 208 220/230 230 240 277 380/400 400 415 440 480 500 $ Price 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 For TeSys D LC1D115, D150 Catalog Number 50 Hz LX1D8B5 LX1D8C5 LX1D8D5 LX1D8E5 LX1D8F5 LX1D8FE5 — LX1D8FC5 — LX1D8M5 LX1D8P5 LX1D8U5 — LX1D8Q5 LX1D8V5 LX1D8N5 LX1D8R5 — LX1D8S5 Catalog Number 60 Hz LX1D8B6 — — LX1D8E6 LX1D8F6 — LX1D8G6 — LX1D8L6 LX1D8M6 — LX1D8U6 LX1D8W6 LX1D8Q6 — — LX1D8R6 LX1D8T6 — Catalog Number 50/60 Hz LX1D8B7 LX1D8C7 LX1D8D7 LX1D8E7 LX1D8F7 LX1D8FE7 LX1D8G7 LX1D8FC7 LX1D8L7 LX1D8M7 LX1D8P7 LX1D8U7 LX1D8W7 LX1D8Q7 LX1D8V7 LX1D8N7 LX1D8R7 LX1D8T7 LX1D8S6 $ Price 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 For old style and new TeSys style contactors where the catalog number may or may not include the auxiliary contact arrangement. 50/60 Hz 140 VA (Inductance: 0.9) 7.5 VA (Inductance: 0.9) 80–115% of nominal voltage Specification 50 Hz 60 Hz Average consumption: -inrush (inductance 0.8) 300 VA 300 VA -sealed (inductance 0.3) 22 VA 22 VA Operating range at 85–110% of 55 °C / 131 °F nominal voltage 50/60 Hz 350 VA (Inductance: 0.9) 18 VA (Inductance: 0.9) 80–115% of nominal voltage For LC1F115, F150, F185, F265, F330, F400, F500, F630, F780, F800 LX1 coils are the standard coils that are included when a voltage code is added to the contactor part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX1 and LX9 coils can be used on the previous F-line contactors. Device Type LX1D6 Hz Catalog Number Suffixg Catalog Number 24 V 48 V 110 V 120 V 208 V 220 V 240 V 277 V 380 V 415 V 440 V 480 V 600 V $ Price 50 LX1FF• 024 048 110 127 200 220 240 264 380 415 415 500 600 78.00 F115–F150 60 LX1FF• 020 040 092 095 162 184 187 220 316 340 360 380 475 78.00 — 048 110 127 200 220 220 260 380 415 415 500 — 78.00 40–400 LX9FF• 50 LX1FG• 024 048 110 127 200 220 240 264 380 415 415 450 600 108.00 F185 60 LX1FG• 020 040 092 095 162 184 187 220 316 340 360 380 475 108.00 F225 — 048 110 127 200 220 220 260 380 415 415 500 — 108.00 40–400 LX9FG• 40–400 LX1FH• 0242 0482 1102 1272 2002 2202 2402 2772 3802 3802 4402 5002 6002 138.00 F265–F330 40–400 LX9FH• — 0482 1102 1272 2002 2202 2402 2772 3802 3802 ... 5002 — 138.00 — 048 110 110 200 220 240 280 380 415 415 415 600 287.00 40–400 LX1FJ• F400d 40–400 LX9FJ• f 910 917 925 925 930 931 932 932 936 936 937 937 — 287.00 40–400 LX1FK• — 048 110 110 200 220 240 280 380 415 415 415 600 360.00 F500d 40–400 LX9FK• f 910 917 925 925 930 931 932 932 936 936 937 937 — 360.00 40–400 LX1FL• — 048 110 110 200 220 240 260 380 415 415 415 600 398.00 F630d 40–400 LX9FL• f 910 917 924 925 930 930 931 932 935 936 936 937 — 483.00 — — 110 110 200 220 220 280 380 415 415 415 — 795.00 F780, FX c 40–400 LX1FX• F800 50/60 LX4F8• e — — FW FW — MW MW — QW QW QW — — 725.00 c LC1F780 contactors operate on 2 coils as a set. The LX1FX part number includes both coils. d The 600 V coils for the F400, F500 and F630 do not include an auxiliary contact for holding circuits. If required, select appropriate contacts from page 18-8. e Also requires rectifier DR5TE4U for 110–240 V coils, DR5TE4S for 380–440 V coils. See Table 18.64 for pricing. f Coil circuit requires a separately mounted rectifier. Order from Table 18.64. g Complete the catalog number by adding the suffix (for example, LX1FF024). Application Note on Contactor Drop-out Times: Contactors using LX1, FH, FJ, FK, FL, and FX coils have longer drop-out times. For critical applications such as emergency stop functions: • • • Select a fast drop-out coil (LX9), or Use a maintained contact Stop button, or Use an interposing relay. TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-40 to 18-47 18-18 I12 Discount Schedule Table 18.64: Coil LX9F•910 LX9F•917 LX9F•925 LX9F•926 LX9F•931 LX9F•936 LX9F•937 LX9F•938 Rectifier Table Rectifier Catalog Number DR5TF4V DR5TF4V DR5TE4U DR5TE4U DR5TE4U DR5TE4S DR5TE4S DR5TE4S $ Price 75.00 75.00 75.00 75.00 75.00 75.00 75.00 75.00 © 2012 Schneider Electric All Rights Reserved Contactor Repair Parts TeSys™ D, and Old D2 DC Coils Refer to Catalog 8502CT9901 www.schneider-electric.us For Old D2 LP1D09, D12, D18 ac Rated Nominal Voltage V Catalog Number Catalog Number Wide Range 12 21b 24 36 48 60 72 110 125 220 250 440 600 LX4D2JD LX4D2ZD LX4D2BD LX4D2CD LX4D2ED LX4D2ND LX4D2SD LX4D2FD LX4D2GD LX4D2MD LX4D2UD LX4D2RD LX4D2XD LX4D2JW — LX4D2BW LX4D2CW LX4D2EW — LX4D2SW LX4D2FW — LX4D2MW — — — Table 18.67: $ Price ced a ep l R k— ducts c o t o e d S ys P r t i L i m y T eS b 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 For Old D2 LP1D40, D50, D65 ac Rated Nominal Voltage V Catalog Number Catalog Number Wide Range 12 24 36 48 60 72 110 125 220 250 440 600 LX4D6JD LX4D6BD LX4D6CD LX4D6ED LX4D6ND LX4D6SD LX4D6FD LX4D6GD LX4D6MD LX4D6UD LX4D6RD LX4D6XD LX4D6JW LX4D6BW LX4D6CW LX4D6EW — LX4D6SW LX4D6FW — LX4D6MW — — — ce a l p Re ts — k toc roduc S ited Sys P m i L Te by Specifications Table 18.66: 12 21 b 24 36 48 60 72 110 125 220 250 440 600 124.00 124.00 124.00 Specifications 9W 80–110% of nominal voltage 11 W 70–125% of nominal voltage For Old D2 LP1D25, D32 ac Rated Nominal Voltage V d Table 18.68: Catalog Number Catalog Number Wide Range $ Price LX4D4JD LX4D4ZD LX4D4BD LX4D4CD LX4D4ED LX4D4ND LX4D4SD LX4D4FD LX4D4GD LX4D4MD LX4D4UD LX4D4RD LX4D4XD LX4D4JW — LX4D4BW LX4D4CW LX4D4EW — LX4D4SW LX4D4FW — LX4D4MW — — — 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 d ace l p Re ts — k toc roduc S ited eSys P m i L T by Specifications Average consumption 11 W 13 W Operating range at 80–110% of nominal 70–125% of nominal < 55 °C / 131 °F voltage voltage a For old style contactors where the catalog number includes the auxiliary contact arrangement (for example, LP1D2510). The new style TeSys DC controlled contactors (for example, LC1D25BD) do not have replaceable coils. b For use in 24 V applications with serial timer modules. Refer to page 18-10. c No replacement DC coils for TeSys D contactors. TeSys DC Coil Specifications Average consumption Operating range Inrush 5.4 W 70–125% @ 60oC Sealed 5.4 W Inrush 19 W LCID••A 75–125% @ 60oC Sealed 7.4 W Low consumption Inrush 2.4 W LC1D09-D32, 70–125% @ 60oC LC1DT20–LC1DT40 Sealed 2.4 W Note: DC coils for LC1D09–D32, LC1DT20–LC1DT40, and LCID••A contactors are not replaceable. LC1D09-D32, LC1DT20–LC1DT40 Average consumption Operating range at < 55 °C /131 °F 22 W 80–110% of nominal voltage 23 W 75–120% of nominal voltage For Old D2 LP1D80 and LC1D80a Rated Nominal Voltage V Catalog Number Catalog Number Wide Range d 12 24 36 48 60 72 110 125 220 250 440 600 LX4D7JD LX4D7BD LX4D7CD LX4D7ED LX4D7ND LX4D7SD LX4D7FD LX4D7GD LX4D7MD LX4D7UD LX4D7RD LX4D7XD LX4D7JW LX4D7BW LX4D7CW LX4D7EW — LX4D7SW LX4D7FW — LX4D7MW — — — $ Price 134.00 134.00 134.00 Specifications Average consumption 22 W 23 W Operating range 80–110% 70–120% at < 55 °C / 131 °F nominal voltage nominal voltage d Wide range coils cannot be used with contactors using both front- and side-mounting auxiliaries. Table 18.69: For TeSys D LC1D115, 150 Rated Nominal Voltage V Catalog Number 24 48 60 72 110 125 220 250 440 LX4D8BD LX4D8ED LX4D8ND LX4D8SD LX4D8FD LX4D8GD LX4D8MD LX4D8UD LX4D8RD Average Consumption Operating range at < 55 °C / 131 °F $ Price 78.00 78.00 Inrush 365 W, Sealed 5 W 70%–120% of nominal voltage TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6 TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . .page 18-16 TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 © 2012 Schneider Electric All Rights Reserved I12 Discount Schedule IEC CONTACTORS AND STARTERS Average consumption Operating range at –55 °C / 131 °F $ Price 18-19 18 Table 18.65: Contactor Repair Parts TeSys™ F DC Coils Refer to Catalog 8502CT9901 www.schneider-electric.us TeSys F DC Coils LX4 coils are the standard coils when a voltage code is added to the part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX4 and LX9 coils can be used on previous F-line devices. Table 18.70: Device Type LX4 Coils for LC1F115, F150, F185, F265, F400, F500, F630, F780, F800 • Catalog Number 24 V • • • • • • • • • • • F115, F150 F185, F225 F265, F330 36V 48 V 60 V 72 V Catalog Number Suffix 110 V 125 V 18 LX4FF 024 035 048 060 070 110 125 LX4FG 024 035 048 060 070 110 125 024 035 048 060 070 110 125 LX4FH LX4FJ — — 048 060 070 110 125 F400 LX9FJ c — — 918 — — 926 927 — — 048 060 070 110 125 LX4FK F500 LX9FK c — — 918 — — 926 927 — — 048 060 070 110 125 LX4FL F630 — — 918 — — 926 927 LX9FK c F780 LX4FX a — — — — — 110 125 F800 LX4F8 b — — — — — FW FW a LC1F780 contactors operate on 2 coils as a set. The LX4FX part number includes both coils. b Also requires rectifier DR5TE4U, $72.00 list price. c Coil circuit requires a separately mounted resistor. Order from Table 18.71 below. Table 18.71: 220 V 250 V 440 V 220 220 220 220 932 220 932 220 932 220 MW 250 250 250 250 — 250 — 250 — 250 — 440 440 440 440 938 440 938 440 938 440 QW $ Price 78.00 108.00 138.00 287.00 287.00 360.00 360.00 398.00 398.00 795.00 725.00 LX9 Coils and Resistors IEC CONTACTORS AND STARTERS Coil Resistor Catalog Number LX9FJ918 LX9FJ926 LX9FJ927 LX9FJ932 LX9FJ938 DR2SC0047 DR2SC0030 DR2SC0390 DR2SC1200 DR2SC4700 Qty. Required $ Price 1 1 1 1 1 13.70 13.80 13.70 13.70 13.70 Coil Resistor Catalog Number Qty. Required LX9FK918 LX9FK926 LX9FK927 LX9FK932 LX9FK938 DR2SC0039 DR2SC0220 DR2SC0330 DR2SC1000 DR2SC3300 1 1 1 1 1 $ Price 13.70 13.70 13.70 13.70 13.70 Coil Resistor Catalog Number Qty. Required LX9FL918 LX9FL925 LX9FL926 LX9FL931 LX9FL937 DR2SC0047 DR2SC0270 DR2SC0330 DR2SC1000 DR2SC3900 2 2 2 2 2 $ Price 13.70 13.70 13.70 13.70 13.70 TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7 TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16 TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 18-20 I12 Discount Schedule © 2012 Schneider Electric All Rights Reserved Enclosed Starters TeSys™ D in Metal Enclosures Refer to Catalog 8502CT9901 www.schneider-electric.us TeSys D enclosed full-voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The enclosed D-line accepts standard D-Line accessories and all Insta-Kits™ control units and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or Schneider Electric sales office. Table 18.72: Enclosed Full Voltage Non-Reversing Starters Max. Horsepower Ratings (AC3) 1 Phase 3 Phase 115 230 200 V 230 V 460 V 575V 0.333 1 2 3 3 5 5 7.5 10 15 2 3 5 5 7.5 10 12 20 30 2 3 5 7.5 10 10 15 20 30 5 7.5 10 15 20 30 40 40 60 7.5 10 15 20 25 30 40 50 60 Table 18.73: 1 1 1 1 1 1 1 1 1 Auxiliary Contacts On Each Contactor 200V 230 V 460 V 575 V N.O. N.C. 2 3 5 5 7.5 10 12 20 30 2 3 5 7.5 10 10 15 20 30 5 7.5 10 15 20 30 40 40 60 7.5 10 15 20 25 30 40 50 60 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 9 12 18 25 32 40 50 65 80 LE1D093A62 O G 7 1 07 Wiring Method Control Power Transformer f Contactor/Starter Coil Voltage g Coil Frequency h Overload Relay Type j Overload Relay Range i fControl Power Transformer Add price from page 18-23. Select letter for primary voltage of CPT: No Transformer used 208 240 480 600 Code Oa L M T X a Letter O, not zero. Note: If control transformer is used, the only options available are 24 or 120 V as the secondary of the transformer. Also, DC voltages are not available when control power transformer is used. gContactor/Starter Coil Voltage Select coil voltage from table: Voltage 24 120 208 240 480 AC B G L U T X DC B — — — — — 600 Frequency Select: 7 = dual frequency coils (50/60 Hz.) 6 = 60 Hz. D=DC Note: For 9 to 65 A contactors, only dual frequency coils are available; 80 A contactors, the 24–240 V coils are dual frequency only (50/60 Hz.). The 480–600 V coils are 60 Hz. only. See catalog 8502CT9901 for other restrictions. jOverload 109. 137. 153. 170. 191. 273. 300. 393. 473. $ Price LE2D093A62••••• LE2D123A62••••• LE2D183A62••••• LE2D253A62••••• LE2D323A62••••• LE2D403A62••••• LE2D503A62••••• LE2D653A62••••• LE2D803A62••••• Table 18.75: Base Catalog Number hCoil LE1D093A62••••• LE1D123A62••••• LE1D183A62••••• LE1D253A62••••• LE1D323A62••••• LE1D403A62••••• LE1D503A62••••• LE1D653A62••••• LE1D803A62••••• Current Rating Catalog Number of Contactor Type 1 Catalog Number Nomenclature Catalog Number Example: Voltage $ Price Type 12/3R LE1D093A72••••• LE1D123A72••••• LE1D183A72••••• LE1D253A72••••• LE1D323A72••••• LE1D403A72••••• LE1D503A72••••• LE1D653A72••••• LE1D803A72••••• 175. 202. 219. 235. 245. 393. 420. 514. 610. Enclosed Full Voltage Reversing Starters Max. Horsepower Ratings (AC3) 3 Phase Table 18.74: 9 12 18 25 32 40 50 65 80 Catalog Number Code 01 02 03 04 05 06 07 08 10 12 13 14 16 18 21 Catalog Number $ Price Type 12/3R 305. 355. 385. 415. 464. 655. 710. 900. 1248. LE2D093A72••••• LE2D123A72••••• LE2D183A72••••• LE2D253A72••••• LE2D323A72••••• LE2D403A72••••• LE2D503A72••••• LE2D653A72••••• LE2D803A72••••• 382. 453. 483. 513. 573. 819. 874. 1030. 1412. iOverload Relay Range (Select code from the table below) Range For use on Contactors D09–D32b D09–D32b D09–D32b D09–D32b D09–D32b D09–D32b D09–D32b D09–D32 D09–D32 D09–D32 D40, D50, D65 D09–D32 D12–D32 D40, D50, D65 D18–D32 D25–D32b D25–D32c D80 D40, D50, D65 D25–D32c D25–D32 D40, D50, D65 D40, D50, D65 D40, D50, D65 D80 D80 D80 D80 D65–D80 D65–D80 D40, D50, D65 $ Price Adder 0.1–0.16 60. 0.16–0.25 60. 0.25–0.40 60. 0.40–0.63 60. 0.63–1.0 60. 1.0–1.6 60. 1.6–2.5 60. 2.5–4 60. 4–6 60. 5.5–8 60. 9–13 107. 7–10 62. 9–13 62. 12–18 107. 12–18 62. 62. 16–24 17–25 62. 22 17–25 107. 25 17–25 107. 30 23-28 73. 32 23–32 73. 32 23–32 107. 40 30–40 107. 50 37–50 107. 53 30–38 107. 55 30–40 107. 57 37–50 107. 59 48–65 107. 61 55–70 107. 63 63–80 107. 65 48–65 107. b Available for Class 10 only. c Available for Class 20 only. Note: If no overload relay is required, leave this portion of the catalog blank. Add appropriate price adder to the base price of the starter. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48 relay type Select: 0 = No overload relay 1 = Class 10 Trip 2 = Class 20 Trip © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule IEC CONTACTORS AND STARTERS 1 2 2 3 3 5 7.5 1 1 1 1 1 1 1 1 1 $ Price 18-21 18 0.5 Auxiliary Contacts Current Rating Catalog Number of Contactor N.O. N.C. Type 1 Enclosed Combination Starters TeSys™ D Fusible Disconnect Switch or Circuit Breaker Refer to Catalog 8502CT9901 www.schneider-electric.us IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. All devices provide Type 2 Coordination through 30 hp at 460 V. Devices are available in Type 1 and Type 12/3R enclosures. The IEC combination starter line accepts standard TeSys D accessories and all Insta-Kits™ pilot devices and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office. NOTE: Use tables and notes from page 18-21 to complete the catalog numbers. Table 18.76: Enclosed Full Voltage Non-Reversing Fusible Combination Starters Max. Horsepower Ratings (AC3) Fuse Clip Rating 3 Phase 200 V 2 3 5 5 7.5 10 230 V 2 3 5 7.5 10 10 18 Table 18.77: 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 Amperes 30 A 30 A 30 A 30 A 60 A 60 A Fuse Clip Rating 3 Phase IEC CONTACTORS AND STARTERS 230 V 2 3 5 7.5 10 10 Table 18.78: 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 Amperes 30 A 30 A 30 A 30 A 60 A 60 A 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 426. 468. 484. 500. 653. 708. Type 12/3R LE1D096B72••••• LE1D126B72••••• LE1D186B72••••• LE1D256B72••••• LE1D326C72••••• LE1D406C72••••• $ Price 551. 592. 607. 623. 829. 877. Aux. Contacts Each Contactor N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number $ Price Type 1 LE2D096B62••••• LE2D126B62••••• LE2D186B62••••• LE2D256B62••••• LE2D326C62••••• LE2D406C62••••• 712. 778. 808. 833. 1089. 1179. Catalog Number Type 12/3R LE2D096B72••••• LE2D126B72••••• LE2D186B72••••• LE2D256B72••••• LE2D326C72••••• LE2D406C72••••• $ Price 837. 915. 950. 980. 1281. 1371. Circuit Breaker Maximum Current Rating Current Rating of Contactor 15 A 15 A 30 A 30 A 50 A 50 A 9 12 18 25 32 40 Catalog Number $ Price Type 1 LE1D097D62••••• LE1D127D62••••• LE1D187E62••••• LE1D257E62••••• LE1D327F62••••• LE1D407F62••••• 569. 622. 647. 668. 870. 944. Catalog Number Type 12/3R LE1D097D72••••• LE1D127D72••••• LE1D187E72••••• LE1D257E72••••• LE1D327F72••••• LE1D407F72••••• $ Price 730. 789. 808. 834. 1088. 1179. N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Circuit Breaker Maximum Current Rating Current Rating of Contactor 15 A 15 A 30 A 30 A 50 A 50 A 9 12 18 25 32 40 Catalog Number $ Price Type 1 LE2D097D62••••• LE2D127D62••••• LE2D187E62••••• LE2D257E62••••• LE2D327F62••••• LE2D407F62••••• 836. 944. 1010. 1075. 1403. 1522. Catalog Number Type 12/3R LE2D097D72••••• LE2D127D72••••• LE2D187E72••••• LE2D257E72••••• LE2D327F72••••• LE2D407F72••••• $ Price 972. 1096. 1174. 1251. 1631. 1770. N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number Type 1 LE1D096A62••••• LE1D126A62••••• LE1D186A62••••• LE1D256A62••••• LE1D326A62••••• LE1D406A62••••• $ Price 416. 458. 474. 490. 643. 698. Catalog Number Type 12/3R LE1D096A72••••• LE1D126A72••••• LE1D186A72••••• LE1D256A72••••• LE1D326A72••••• LE1D406A72••••• $ Price 541. 532. 597. 613. 819. 867. Enclosed Full Voltage Reversing Non-Fused Combination Starters Max. Horsepower Ratings (AC3) Aux. Contacts Each Contactor 3 Phase 200 V 2 3 5 5 7.5 10 N.C. 1 1 1 1 1 1 Auxiliary Contacts 3 Phase Table 18.81: Type 1 LE1D096B62••••• LE1D126B62••••• LE1D186B62••••• LE1D256B62••••• LE1D326C62••••• LE1D406C62••••• Catalog Number Enclosed Full Voltage Non-Reversing Non-Fused Combination Starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 N.O. 1 1 1 1 1 1 Auxiliary Contacts Each Contactor 3 Phase Table 18.80: 9 12 18 25 32 40 $ Price Enclosed Full Voltage Reversing Circuit Breaker Combination Starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 UL Class CC CC J J J J Auxiliary Contacts 3 Phase Table 18.79: N.C. 1 1 1 1 1 1 Catalog Number Enclosed Full Voltage Non-Reversing Circuit Breaker Combination Starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 N.O. 1 1 1 1 1 1 Current Rating of Contactor Enclosed Full Voltage Reversing Fusible Combination Starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 5 7.5 10 UL Class CC CC J J J J Auxiliary Contacts 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number Type 1 LE2D096A62••••• LE2D126A62••••• LE2D186A62••••• LE2D256A62••••• LE2D326A62••••• LE2D406A62••••• $ Price 702. 768. 798. 823. 1079. 1169. Catalog Number Type 12/3R LE2D096A72••••• LE2D126A72••••• LE2D186A72••••• LE2D256A72••••• LE2D326A72••••• LE2D406A72••••• $ Price 827. 905. 940. 970. 1271. 1361. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-48 18-22 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Enclosed Combination Starters Enclosure Modifications/Insta-Kits™/Overload Relay Refer to Catalog 8502CT9901 www.schneider-electric.us Factory Modifications and Insta-Kits™ Selection Add the factory modification code to the end of the catalog number created from page 18-21. With the use of Insta-Kits™, only one operator scheme is allowed. Only the combinations of operators and pilot lights shown below can be ordered. L2 13 OLR 95 96 B Pilot lights will be at the coil voltage indicated in the catalog number for the starter. M Table 18.82: 14 Start/Stop Control Units Only For-Rev-Stop Push Button Start/Stop Push Button I/O (Start/Stop) Push Button I/O Push Button (double touch) Emergency Stop Hand-Off-Auto Selector Switch On/Off Selector Switch Start/Mushroom Head Stop Push Button Pilot Lights only LED Pilot light, 24, 120 or 240 V Green-Red Pilot Light, Direct Supply, 24 or 120 V b Green-Red Transformer Pilot Light, 120, 208/240, 480 or 600 V b Available Combination of Control Units and Pilot Lights Hand-Off-Auto Selector Switch w/24, 120, or 240 V LED Pilot Light Start/Stop Push Button w/ 24, 120 or 240 V LED Pilot Light On/Off Selector w/ 24, 120 or 240 V LED Pilot Light Start/Stop Push Button w/ Green-Red Transformer Pilot Light Start/Stop Push Button w/Green-Red Pilot Light Hand-Off-Auto Selector Switch w/Green-Red Pilot Light Hand-Off-Auto Selector Switch w/Green-Red Transformer Pilot Light On/Off Selector w/Green-Red Pilot Light On/Off Selector w/Green-Red Transformer Pilot Light L2 ON X1 X2 OLR B 95 96 PL 1 23 4 A 61 M 62 X1 X2 PL On-Off Selector Switch L1 L2 OFF X1 HAND AUTO 3 4 3 PL X2 95 96 M 4 61 62 X1 PL X2 Remote by Customer Connection HOA Selector Switch L1 L2 L3 13 M A 14 98 96 97 95 T2 Table 18.83: T3 D-Line AC Magnetic Starter 2-3 Poll d L1 L2 L3 21 + 21 + B R A 95 98 96 A06L A06G N/A A06I N/A A06E A06D A06X 131. 65. — 83. — 65. 65. 65. LA9CA06LT LA9CA06GT N/A LA9CA06IO N/A LA9CA06ET LA9CA06DT LA9CA06XT 71.00 32.80 — 41.50 — 32.80 41.50 63.00 A16S A06S 134. 112. LA9CA16STd LA9CA06STd 66.00 62.00 A06F 207. LA9CA06FTd 113.00 A16U 213. LA9CA16UTd 177.00 A16V 213. LA9CA16VTd 177.00 A16W 213. LA9CA16WTd 177.00 A06N 177. LA9CA06NTd 95.00 A06V A06U 177. 273. LA9CA06VT LA9CA06UT 95.00 97.00 A06J 273. LA9CA06JTd 147.00 A06W A06H 177. 273. LA9CA06WT LA9CA06HTd 95.00 147.00 Insta-Kits™ Selection Voltage Codes for Pilot Lights 24 120 208/240 480 600 Code B G M T X Table 18.85: Voltage Codes for Control Power Transformers 120 208 240 480 600 208 240 24 480 600 T X 120 + Secondary Voltage Code 97 $ Price Voltage (Vac) Primary Voltage 22 + 22 Insta-Kits (for field installation) Total VA Insta-Kits™ Catalog Number $ Price 50 LA9TFD32d 140.00 100 LA9TFD80d 246.00 150 LA9TFD15d 343.00 Complete the part number for the Insta-Kits™ by selecting the voltage code from the appropriate tables below. Table 18.84: B F A $ Price Control Power Transformer Standard VA, 2 Fuses in Primary, 1 Fuse in Secondary A206P 260. c — 50 VA extra, 2 Fuses in Primary, 1 Fuse in Secondary A207P 456. c — 100 VA extra, 2 Fuses in Primary, 1 Fuse in Secondary A208P 634. c — a Add these forms to the catalog number selected on page 18-21. The numbers as shown are for use in NEMA 1 Enclosures. For uses in NEMA 12/3R change the 6 to a 7 (ex A06U becomes A07U). Price remains the same. The change DOES NOT apply to control power transformer forms. b Pilot lights are wired such that the light is on when the contactor is energized. For non-LED type pilot lights, a green lens is installed on the unit when shipped. A red lens is included for use as applicable. c Select Insta-Kits™ from table below. B T1 Factory Modification Codea Description L1 OFF Factory Modifications E D C B A L M "C" T1 T2 T3 D-Line AC Magnetic Reversing Starter 3-Pole © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule 18-23 IEC CONTACTORS AND STARTERS START STOP 1 23 4 A 18 L1 Contactors TeSys™ K 3-Pole Non-Reversing Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us 3-Pole Non-Reversing Mini-Contactors Table 18.86: AC Operating Coils Maximum Horsepower Ratings 1Ø Maximum Current Auxiliary Contacts Type of Connection 3Ø Inductive Resistive AC1 (A) 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp AC3 (A) 0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp LC1K09● Table 18.87: Catalog Number N.O. N.C. 1 — 1 — 1 — — 1 — 1 — 1 $ Price LC1K0610 a b LC1K0601 ab LC1K0910 ab LC1K0901 ab LC1K1210 ab LC1K1201 ab 57. 57. 75. 75. 86. 86. Coil Voltage Codes for AC Contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required (for example, J72). Price adder $10.00. Vac 50/60 Hz 12 24 42 48 110 120 127 200/ 208 220/ 230 230 230/ 240 277 380/ 400 400/ 415 440 480 660/ 690 Code J7 B7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 UE7 Q7 N7 R7 T7 Y7 18 Table 18.88: DC Operating Coils IEC CONTACTORS AND STARTERS 0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp a 1 — 1 — 1 — LP1K0610 ab LP1K0601 ab LP1K0910 ab LP1K0901 ab LP1K1210 ab LP1K1201 ab — 1 — 1 — 1 75. 75. 92. 92. 106. 106. See Table 18.89: For TeSys K contactors with spring terminal clamps, add a 3 before the coil voltage code (for example, LC1K06103G7). For TeSys K contactors with solder pin terminals, add a 5 before the coil voltage code (for example, LC1K09105B7). For TeSys K contactors with slip-on terminals, add a 7 before the coil voltage code (for example, LC1K12107M7). Complete the catalog number with the appropriate coil voltage code (for example, LC1K0610G7). b Table 18.89: Coil Voltage Codes for DC Contactors Coil with integral suppression device available. Add 3 to the code required (for example, JD3). Price adder $10.00 a Vdc Code 3 W inrush. a 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD , Table 18.90: DC–Low Consumption Operating Coils (devices have built-in transient suppression) LP4K09● 0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 1.5 3 3 7.5 10 12 20 Screw-clamp 0.5 a b LR2K0316 E164862 CCN NLDX (screw terminals) LR43364 Class 3211 04 E164862 CCN NLDX2 (slip-on & solder-pin terminals) 18-24 — 1 — 1 — 1 LP4K0610 LP4K0601 LP4K0910 LP4K0901 LP4K1210 LP4K1201 ab ab ab ab ab ab 92. 92. 110. 110. 126. 126. See Table 18.91: For TeSys K contactors with spring terminal clamps, add a 3 before the coil voltage code (for example, LC1K06103G7). For TeSys K contactors with solder pin terminals, add a 5 before the coil voltage code (for example, LC1K09105B7). For TeSys K contactors with slip-on terminals, add a 7 before the coil voltage code (for example, LC1K12107M7). Complete the catalog number with the appropriate coil voltage code (for example, LC1K0610G7). Table 18.91: a 1 — 1 — 1 — Coil Voltage Codes for DC Contactors—Low Consumption a Vdc 12 24 48 72 Code JW3 BW3 EW3 SW3 1.8 inrush sealed. Table 18.92: Overload Relays for 3-Pole Contactors with Screw-Clamp Terminals Class 10, Relay setting range–A Catalog Number 0.1 to 0.16 0.16 to 0.23 0.23 to 0.36 0.36 to 0.54 0.54 to 0.8 0.8 to 1.2 1.2 to 1.8 1.8 to 2.6 2.6 to 3.7 3.8 to 5.5 5.5 to 8 8 to 11.5 10 to 14 LR2K0301 LR2K0302 LR2K0303 LR2K0304 LR2K0305 LR2K0306 LR2K0307 LR2K0308 LR2K0310 LR2K0312 LR2K0314 LR2K0316 LR2K0321 $ Price 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. LR2K overload relays: • • • • • • AC or DC protection Ambient compensated bimetallic Class 10 Single phase sensitivity Manual or auto reset Full load current dial Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactors TeSys™ K 3-Pole Reversing Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us 3-Pole Reversing Mini-Contactors AC Operating Coils Maximum Horsepower Ratings 1Ø Maximum Current 3Ø 115V hp 230V hp 200V hp 230V hp 460V hp 575V hp 0.5 1.5 1.5 1.5 3 3 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 Inductive Resistive AC3 AC1 A A Auxiliary Contacts Type of Connection 6 15 Screw-clamp 5 9 20 Screw-clamp 10 12 20 Screw-clamp LC2K09107 Vac 50/60 Hz Code Table 18.95: 12 24 42 48 110 120 127 J7 B7 D7 E7 F7 G7 FC7 200/ 208 L7 220/ 230 M7 230 P7 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 12 JD 20 ZD 24 BD 36 CD 48 ED 60 ND 72 SD 100 KD 110 FD 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp a b 130. 130. 167. 167. 191. 191. 230/ 240 U7 380/ 400 Q7 277 UE7 400/ 415 N7 440 480 R7 T7 660/ 690 Y7 1 — 1 — 1 — LP2K0610 ab LP2K0601 ab LP2K0910 ab LP2K0901 ab LP2K1210 ab LP2K1201 ab — 1 — 1 — 1 167. 167. 202. 202. 232. 232. 125 GD 200 LD 220 MD 230 MPD 240 MUD 250 UD DC–Low Consumption Operating Coils (devices have built-in transient suppression) 0.5 Table 18.98: LC2K0610 ab LC2K0601 ab LC2K0910 ab LC2K0901 ab LC2K1210 ab LC2K1201 ab Coil Voltage Codes for DC Contactors Coil with integral suppression device available. Add 3 to the code required. Example: JD3. Price adder $20.00. Vdc Code Table 18.97: — 1 — 1 — 1 DC Operating Coils 1.5 LP2K0910 1 — 1 — 1 — $ Price Coil Voltage Codes for AC Contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example: J72. Price adder $20.00. 0.5 Table 18.96: N.C. 1 — 1 — 1 — — 1 — 1 — 1 LP5K0610 ab LP5K0601 ab LP5K0910 ab LP5K0901 ab LP5K1210 ab LP5K1201 ab 202. 202. 238. 238. 274. 274. Coil Voltage Codes for DC Contactors—Low Consumption Vdc 12 24 48 Code JW3 BW3 EW3 For TeSys K contactors with spring terminal clamps, add a 3 before the coil voltage code (for example, LP2K09103BD). For TeSys K contactors with solder pin terminals, add a 5 before the coil voltage code (for example, LP5K09105BW3). For TeSys K contactors with slip-on terminals, add a 7 before the coil voltage code (for example, LC2K06107B7). Complete the catalog number with the appropriate coil voltage code (for example, LC1K0610G7). 72 SW3 Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-24 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-27 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49 © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule 18-25 IEC CONTACTORS AND STARTERS Table 18.94: Catalog Number N.O. 18 Table 18.93: Contactors TeSys™ K 4-Pole Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.99: AC Operating Coils Maximum Horsepower Ratings 1Ø 115 V hp Maximum Current 3Ø 230 V hp Inductive Resistive AC3 AC1 (A) (A) Type of Connection 200 V hp 230 V hp 460 V hp 575 V hp 2 3 5 5 9 15 Screw-clamp 10 12 20 5 10 9 12 20 20 Power Poles Catalog Number $ Price N.O. N.C. Screw-clamp 4 2 4 — 2 — LC1K09004 ab LC1K09008 ab LC1K12004 ab 75. 81. 86. Screw-clamp Screw-clamp 4 4 — — LC2K09004 ab LC2K12004 ab 167. 191. 4-Pole Mini Contactor 0.5 LC2K090045 1.5 0.5 1.5 3 3 7.5 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 Table 18.100: Coil Voltage Codes for AC Contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example: J72. Price adder $10.00 ($20.00 for mechanically interlocked contactors) Vac 50/60 Hz Code 12 J7 24 B7 42 D7 48 E7 110 F7 120 G7 127 200/208 220/230 FC7 L7 M7 230 P7 230/ 240 277 380/400 400/415 U7 UE7 Q7 N7 440 R7 480 T7 660/690 Y7 Table 18.101: DC Operating Coils 18 4-Pole Mini Contactor IEC CONTACTORS AND STARTERS Screw-clamp 4 2 4 — 2 — LP1K09004 ab LP1K09008 ab LP1K12004 ab 92. 98. 106. Screw-clamp Screw-clamp 4 4 — — LP2K09004 ab LP2K12004 ab 202. 232. 0.5 1.5 2 3 5 5 9 15 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 5 10 9 12 20 20 Table 18.102: Coil Voltage Codes for DC Contactors Coil with integral suppression device available. Add 3 to the code required. Example: JD3. Price adder $10.00 ($20.00 for mechanically interlocked contactors) Vdc 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Table 18.103: DC–Low Consumption Operating Coils (devices have built-in transient suppression) 4-Pole Mini Contactor 0.5 Screw-clamp 4 2 4 — 2 — LP4K09004 ab LP4K09008 ab LP4K12004 ab 110. 116. 126. Screw-clamp Screw-clamp 4 4 — — LP5K09004 ab LP5K12004 ab 238. 274. Vdc 12 24 48 Code JW3 BW3 EW3 For TeSys K contactors with spring terminal clamps, add a 3 before the coil voltage code (for example, LC1K09103L7). For TeSys K contactors with solder pin terminals, add a 5 before the coil voltage code (for example, LP4K06015JW3). For TeSys K contactors with slip-on terminals, add a 7 before the coil voltage code (for example, LP2K090047BD). Complete the catalog number with the appropriate coil voltage code (for example, LC1K0610G7). 72 SW3 1.5 2 3 5 0.5 1.5 3 3 7.5 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 5 9 15 Screw-clamp 10 12 20 5 10 9 12 20 20 Table 18.104: Coil Voltages for DC Contactors—Low Consumption a b Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-24 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49 18-26 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Contactors and Accessories TeSys™ K Contactors and Accessories Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.105: Instantaneous Auxiliary Contact Blocks Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors. Auxiliary Contacts Type of connection LA1KN11 N.O. 2 — 1 4 Screw clamp 3 2 1 — 2 — 1 4 Slip-on 1 x 0.250 in. or 2 x 0.110 in. 3 2 1 — a Block of 4 contacts cannot be used with LP4K or LP5K contactors. Catalog Number N.C. — 2 1 — 1 2 3 4 — 2 1 — 1 2 3 4 $ Price LA1KN20 LA1KN02 LA1KN11 LA1KN40 a LA1KN31 a LA1KN22 a LA1KN13 a LA1KN04 a LA1KN207 LA1KN027 LA1KN117 LA1KN407 a LA1KN317 a LA1KN227 a LA1KN137a LA1KN047 a 14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30 14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30 Table 18.106: Electronic Time Delay Auxiliary Contact Blocks Timing Range (S) Type 24–48 Vac or Vdc On-delay 1–30 110–240 Vac On-delay 1–30 Note: Relay outputs, with single pole double throw, 240 Vac/Vdc, 2 A max. Maximum switching capacity 250 VA / 150 W Operating temperature: –10 to + 60°C (14 to 140°F) Reset time: 1.5 s during time delay, 0.5 after time delay Contacts Catalog Number $ Price SPDT SPDT LA2KT2E LA2KT2U 32.80 32.80 Table 18.107: Suppressor Module with Incorporated LED Indicator Clip-on front mounting $ Price each 12–24 Vac/Vdc Varistor 5 LA4KE1B b 9.80 32–48 Vac/Vdc Varistor 5 LA4KE1E b 9.80 50–129 Vac/Vdc Varistor 5 LA4KE1FC b 9.80 130–250 Vac/Vdc Varistor 5 LA4KE1UG b 9.80 12–24 Vdc Diode + Zener 5 LA4KC1B c 9.80 32–48 Vdc Diode + Zener 5 LA4KC1E c 9.80 220–250 Vac RC 5 LA4KA1U d 9.80 b Protection by limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1–1.5 times normal). c No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1–1.5 times normal). d Protection by limitation of the transient voltage to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 times normal). Voltage range LA2KT2U Type Table 18.108: Paralleling Links Sold in lots of Catalog Number Table 18.109: Power Connectors Description Sold in lots of Catalog Number For 2 poles with screw-clamp terminals For 4 poles with screw-clamp terminals 4 2 LA9E01 LA9E02 $ Price each 2.20 3.50 $ Price each Description Sold in lots of Catalog Number Set of 6 power connections for reversing contactors with screw-clamp terminals Set of 4 power connections for changeover contactors with screw-clamp terminals 100 LA9K0969 6.20 100 LA9K0970 6.20 Table 18.110: Marking Strips Description Sold in lots of Catalog Number Clips onto front of the contactor 100 LA9D90 $ Price each .06 Table 18.111: Accessories for Overload Relays Description Terminal block for separate clip-on mounting of the overload relay onto 35 mm omega rail (AM1DP200) Type of Connection Catalog Number Screw-clamp LA7K0064 $ Price 11.90 E164862 CCN NLDX LR43364 Class 3211 04 © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule 18-27 18 Voltage (V) IEC CONTACTORS AND STARTERS Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors. LA1KN22 Motor Starters TeSys™ U Simple Motor Starter Refer to Catalog 8502CT0201 www.schneider-electric.us The TeSys U motor starter is integrated, making it simple to choose and install. It consists of a control unit snapped in a power base. TeSys U can be configured to fit specific applications as well. Optional accessories include a reverser, a current limiter, predictive maintenance options, and communication options. For detailed information about TeSys U, visit our website. 1 Power Base 2 + Function Modules 3 Control Unit TeSys U Motor Starter = Auxiliary Contacts Selecting TeSys U Motor Starters in Three Steps Table 18.112: Step 1. Select Power Base (Only two different bases up to 32 A) 18 Control Connection Max. Current (A) Three Phase (HP max.) 200/208 V 220/240 V Single Phase (HP max.) 460 V 575/600 V IEC CONTACTORS AND STARTERS 12 3 3 7.5 With screw terminations 32 10 10 20 12 3 3 7.5 Without screw terminations 32 10 10 20 • For use with reversng modules or communication modules with prewired connector 10 25 10 25 120 V 240 V 1.5 2 1.5 2 2 5 2 5 Self-Protected Power Base Catalog Number LUB12 LUB32 LUB120• LUB320• $ Price 246.00 345.00 276.00 375.00 Table 18.113: Step 2. Select Control Unit g Standard Advanced Advanced Advanced 3-phase $ Price 3-phase $ Price single-phase $ Price 3-phase $ Price Class 10 trip e Class 10 trip e Class 10 trip e Class 20 trip e 0.15–0.6 LUCAX6•• 120.00 LUCBX6•• 150.00 LUCCX6•• 150.00 LUCDX6•• 150.00 0.3–1.4 LUCA1X•• 120.00 LUCB1X•• 150.00 LUCC1X•• 150.00 LUCD1X•• 150.00 1.25–5.0 LUCA05•• 120.00 LUCB05•• 150.00 LUCC05•• 150.00 LUCD05•• 150.00 120.00 LUCB12•• 150.00 LUCC12•• 150.00 LUCD12•• 150.00 3–12 LUCA12•• 4.5–18 LUCA18•• 120.00 LUCB18•• 150.00 LUCC18•• 150.00 LUCD18•• 150.00 8–32 LUCA32•• 120.00 LUCB32•• 150.00 LUCC32•• 150.00 LUCD32•• 150.00 e Complete the catalog number by adding appropriate code from voltage code table below (for example, LUCAX6FU). f The control unit contains solid-state overload relay and control power source for TeSys U. For more details on the different control units, their functions, and placement on the power base, see 18-29 Setting Range (A) Power Base Table 18.114: Voltage Codes Control Unit Volts 24 48–72 110–240 DC BLg — — AC B — — DC or AC — ESh FU g DC voltage with range of 0.90 to 1.10 of nominal. h 48–72 Vdc; 48 Vac Table 18.115: Step 3. Select Auxiliary Contacts (optional) Contact State for Each Modea Terminals Auxiliary Contact Contact Indicates Auxiliary Contact Blocks Ready condition Screw Fault condition Ready condition Screw Fault condition Auxiliary Contact Function Modules Contact Normal Status Off Ready Run Short Circuit Trip Overload Trip (Manual Reset) Overload Trip (Remote/ Auto Reset)b N.O. N.C. N.O. N.O. O I O O I I I O I I I O O O O I O O O I I I I O Screw Pole state 2 N.O. Screw Pole state 1 N.O. and 1 N.C. O O O I O I I I O O O O I O Screw Pole state 2 N.C. 1 I O I a I indicates closed contact; O indicates open contact b Requires multifunction or advanced control unit plus fault differentiation module LUFDA10. $ Price LUA1C11 LUA1C20 34.5 LUFN20 I I Catalog Number LUFN11 34.5 LUFN02 Table 18.116: Accessories E164862 CCN NLDX LR43364 Class 3211 08 18-28 Accessory Current limiter Reverser Line phase barrier Multifunction control unit Function modules Communication modules Soft starter + Tesys U Powerbus Configuration and connection accessories Quick Description Increases the breaking capacity to 130kA @ 460 V Stacked or side mounted (LU6MB0••• only) Required for use as a self-protected combination starter (UL508E) Has functions for monitoring and predictive maintenance Fault differentiation, thermal overload, motor load indication Integrates into existing networks, major portocols are available Use Altistart U01soft starter with TeSys U Use TeSys U with a prewired system PowerSuite software, busbar, external handle For details & selection, see: Table 18.123 Table 18.119 Table 18.118 Table 18.124 Table 18.125 Table 18.126 Table 18.132 Table 18.128 Table 18.129 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-29 to 18-31 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-50 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Control Units TeSys™ U Simple Motor Starter Refer to Catalog 8502CT0201 www.schneider-electric.us Table 18.117: Control Units and Functions Standard Reference Advanced LUCA LUCB Multifunction LUCC LUCD LUCM IEC CONTACTORS AND STARTERS Protection type Class 10 Class 20 Class 5–30 Single Phase: LUCC Class 10 only Protection functions Short circuit Over current Thermal overload Phase loss Phase imbalance Ground fault Underload, long start, jam Control functions Manual reset Automatic or local/remote reset Fault differentiation Thermal alarm Motor load display Fault history Alarm threshold adjustment Tripping test 18 = built-in the control unit = works with the related function modules (see Table 18.119 on page 30) Power Base and Plug-in Accessories See below where to install accessories on the power base. Only one accessory can be installed in each location. b e j m b j Control Unit or mMultifunction Control Line Phase Barrier Reverser Unit mounts under power base Current Limiter attaches above power base Multifunction Control Unit Control Circuit Contact Block Auxiliary Function or Communication Module Auxiliary Contact Block e Power Base (Front View) © 2012 Schneider Electric All Rights Reserved Side View 18-29 Accessories TeSys™ U Simple Motor Starter Refer to Catalog 8502CT0201 www.schneider-electric.us Table 18.118: Line Phase Barrier (optional) a Catalog Number LU9SP0 Description Line Phase Barrier Incoming line phase barrier to allow the TeSys U to be used as a self protected combination starter according to UL508E a See page 18-29 for placement on the power base. $ Price 15.00 Table 18.119: Reverser Max. Current (A) Control Connection Self-Protected Starter Base 200/208 V 220/240 V 460 V 575 V 3 10 3 10 7.5 20 10 25 12 32 With screw terminations b Three Phase (HP max.) Catalog Number LU2B12b LU2B32b $ Price 488.00 720.00 Voltage code required. Table 18.120: Select Control Unit Optionsde Standard Advanced Advanced Advanced 3-phase $ Price 3-phase $ Price single-phase $ Price 3-phase Class 10 trip c Class 10 trip c Class 10 trip c Class 20 trip c 0.15–0.6 LUCAX6•• 120.00 LUCBX6•• 150.00 LUCCX6•• 150.00 LUCDX6•• 120.00 LUCB1X•• 150.00 LUCC1X•• 150.00 LUCD1X•• 0.3–1.4 LUCA1X•• 1.25–5.0 LUCA05•• 120.00 LUCB05•• 150.00 LUCC05•• 150.00 LUCD05•• 3–12 LUCA12•• 120.00 LUCB12•• 150.00 LUCC12•• 150.00 LUCD12•• 120.00 LUCB18•• 150.00 LUCC18•• 150.00 LUCD18•• 4.5–18 c LUCA18•• 120.00 LUCB32•• 150.00 LUCC32•• 150.00 LUCD32•• 8–32 c LUCA32•• c Complete the catalog number by adding the appropriate code from Table 18.121 (for example, LUCAX6FU). d Control units for 4.5–18 and 8–32 can be used only with 32 A rated power bases (LUB32 / LU2B32). e The control unit contains solid-state overload relay and control power source for TeSys U. For more details on the different control units, their functions, and placement on the power base see page 18-29. Setting Range (A) 18 Reverser Unit Assembled under the Power Base $ Price 150.00 150.00 150.00 150.00 150.00 150.00 IEC CONTACTORS AND STARTERS Table 18.121: Voltage Codes f g h Volts 24 DC BLfg AC B DC or AC — Voltage code to use for a power base with a communication module. DC voltage with range of 0.90 to 1.10 of nominal. 48–72 Vdc; 48 Vac 48–72 — — ESh 110–240 — — FU Table 18.122: Reversing Modules for Field Addition Mounting Beneath Beside Catalog No. LU2MB0 LU6MB0 $ Price 192.00 222.00 Wiring Adapter LU9MR1C LU9MR1 $ Price 31.50 15.00 Note: For LU2MB0 and LU6MB0, voltage code required; must match control unit. Table 18.123: Current Limiter ij Application Technical Data Mounting Catalog Number $ Price Current limiter/isolator Additional current limiting aspects for the starter Direct mounting to LUB• and LU2B• LUALB1 171.00 Limiter cartridge Replacement cartridge for LUALB1 130 kA at 460 V 60 kA at 575 V 130 kA at 460 V 65 kA at 575 V — LUALF1 78.00 Accessory i j Increases the breaking capacity of the motor starter. See page 18-29 for placement on the power base. Table 18.124: Control Unit Multifunction kl Control Unit Multifunction k l Setting Range (A) Multifunction programmable 0.15–0.6 LUCMX6BL 0.3–1.4 LUCM1XBL 1.25–5.0 LUCM05BL 3–12 LUCM12BL 4.5–18 LUCM18BL 8–32 LUCM32BL Offers motor management system capabilities. For more details see the LUCM on page 18-31. See page 18-29 for placement on the power base. $ Price 615.00 Table 18.125: Function Modules mn Module Alarm Differentiation Parallel Wiring Fault differentiation with manual reset (thermal overload) Fault differentiation with auto reset Thermal overload pre-alarm Description Provides indication between an overload trip and a short circuit trip. Signals when the motor current reaches 1.05 of the full load setting on the control unit. Provides a signal proportional to the average currents in the three phases divided by the full Motor load indication load current setting of the control unit. The output corresponds to a load status of 0–2 times the full load setting of the control unit. Provides a convenient way to reduce control wiring and allow for connecting starters to a Parallel wiring communications network by providing 24 Vdc for the starters. m Offers customization for specific application requirements. n See page 18-29 for placement on the power base. For use with: Operation Requirements Advanced control units only 24–250 Vac or Vdc (power from control unit) Advanced control units only 24–250 Vac or Vdc (power from control unit) Advanced or multi-function control units 4–20 mA (requires separate 24 Vdc power supply) Advanced or multi-function LU9G02 control units(24 Vdc only) box and PLC and LU9BN11C or LU9MRC splitter network prewired connector Catalog Number $ Price LUFDH11 156.00 LUFDA10 156.00 LUFW10 156.00 LUFV2 188.00 LUFC00 57.00 Motor Load Indicator 18-30 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Accessories TeSys™ U Simple Motor Starter Refer to Catalog 8502CT0201 www.schneider-electric.us AS-Interface Modbus DeviceNet Profibus Description Catalog Number $ Price ASILUFC5 188.00 ASILUFC51 188.00 LULC033 218.00 LULC15 218.00 LULC08 218.00 LULC14 218.00 LULC07 218.00 LULC09 218.00 Configuration and Connection Accessories \ Table 18.127: Control Circuit Accessories q Accessory Application Technical Data Mounting Catalog Number $ Price Control circuit contact block Switches control circuit power via LUB• handle (NEC430-74 compliance) 5 A at 600 Vac 5 A at 250 Vdc Side mounting to LUB• and LU2B• only LUA8E20 71.00 Kit LU9APN21 140.00 Use to enclose TeSys LUB• only. NEMA 1, 12 Black w/ trip indication NEMA 1, 12 Red/Yellow w/ trip indication NEMA 3R, 4, 4X Red/Yellow without trip indication Kit LU9APN22 140.00 Kit LU9APN24 161.00 LUA4F11 LUA4F12 GVAPK12 39.30 39.30 19.00 CANopen Through-the-door operating mechanism Use with electronic or triac output controllers Angle bracket Support shaft, for use with LUB• q See page 29 for placement on the power base. Control circuit filters Up to 150 Vac max. Directly to coil terminals — — Non-reversing Reversing Table 18.128: PowerSuite Configuration Software and Accessories Item a Catalog Number PowerSuite software VW3A8104 PC connection kit VW3A8106 Pocket PC connection kit VW3A8111 a For complete details on all components included with each item, refer to catalog 8502CT0201. b Items under discount schedule CP4C. $ Price b 225.00 113.00 143.00 Powerbus Table 18.129: GV2 Cabling Accessories—Bus Bars Description Application For feeding 2 GV2 starters or TeSys U controllers 3-Pole, 63 A Bus Bar For feeding 3 GV2 starters or TeSys U controllers For feeding 4 GV2 starters or TeSys U controllers For feeding 5 GV2 starters or TeSys U controllers Pitch 45 54 72 45 54 45 54 72 Standard Pack 1 1 1 1 1 1 1 1 Catalog Number GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 54 1 GV2G554 $ Price Each 23.30 23.30 23.30 28.70 28.70 34.20 34.20 34.20 34.20 Additional accessories and components are available, including: • • • • Mounting accessories Gateways Cabling accessories Magelis™ remote display unit For the complete line of TeSys U-Line motor starter accessories and all technical details (specifications, wiring diagrams, etc.) pertaining to the product line, refer to Catalog 8502CT0201. © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule 18-31 18 Operation For use with: Requirements Advanced or multi-function Allows the TeSys U starter to be connected control units (24 Vdc only) Requires separate 24 Vdc AS-Interface directly to the network using AS-Interface supply and AS-Interface Communication and LU9BN11C or LU9MRC power protocols. network prewired connector or multi-function Requires separate 24 Vdc Allows the TeSys U starter to be connected Advanced AS-Interface V2 units (24 Vdc only) directly to the network using AS-Interface V2 control supply and AS-Interface Communication and LU9BN11C or LU9MRC power protocols. V2 network prewired connector or multi-function Allows the TeSys U starter to be connected Advanced Modbus™ control units (24 Vdc only) Requires separate 24 Vdc to the network using Communication Protocol directly and LU9BN11C or LU9MRC power supply Modbus protocols. prewired connector or multi-function Allows the TeSys U starter to be connected to Advanced Advantys™ STB control units (24 Vdc only) Requires separate 24 Vdc the network using the Advantsys STB Communication and LU9BN11L or LU9MRL power supply protocol prewired connector Advanced or multi-function CANopen Allows the TeSys U starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc Communication the network using the CANopen protocol and LU9BN11L or LU9MRL power supply prewired connector Advanced or multi-function the TeSys Ustarter to be connected to control units (24 Vdc only) Requires separate 24 Vdc Beckoff Communication Allows the network using the Beckoff protocol and LU9BN11L or LU9MRL power supply prewired connector Advanced or multi-function the TeSys U starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc Profibus Communication Allows the network using the Profibus protocol and LU9BN11L or LU9MRL power supply prewired connector Advanced or multi-function DeviceNet™ Allows the TeSys U starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc Communication the network using the Device Net protocol and LU9BN11L or LU9MRL power supply prewired connector o Communication capabilities can be integrated into existing automation architecture via a variety of protocols. p See 18-29 for placement on the power base. Module IEC CONTACTORS AND STARTERS Table 18.126: Communication Modules op Soft Starters ATSU01 Altistart™ Drive and TeSys™ U Simple Motor Starter Refer to Catalog 8502CT9901 www.schneider-electric.us Altistart Drive and TeSys U Motor Starter Table 18.130: Soft Start / Soft Stop Unit for 0.75 to 15 kW Motors (can be combined with the TeSys U starter) Motor Starter Motor Powera 230 V 460 V HP HP Nominal Current Catalog Number $ Price ATSU01N206LT 133.00 ATSU01N209LT ATSU01N212LT 152.00 175.00 ATSU01N222LT 219.00 ATSU01N232LT 300.00 A 3-phase supply voltage: 200 ... 480 V 50/60 Hz 1 2 6 1.5 3 2 5 9 3 7.5 12 5 10 22 7.5 15 10 20 32 a Standard motor power ratings, HP power ratings indicated according to standard UL 508. Table 18.131: Accessories 18 Description Power connector between ATSU 01N2••LT and TeSys U Used for Starter Catalog Number ATSU01N2••T VW3G4104 $ Price 10.00 Table 18.132: TeSys U Starter and Soft Start Unit Combinations Motor Power TeSys U IEC CONTACTORS AND STARTERS Voltage 200 V ATSU01•• b Soft Starter 460 V Power Base Control Unit b HP HP 1 2 ATSU01N206LT LUC•05BL 1.5 3 ATSU01N206LT LUC•12BL 2 5 ATSU01N209LT LUC•12BL LUB 12 3 — ATSU01N212LT LUC•12BL — 7.5 ATSU01N212LT LUC •18BL 5 10 ATSU01N222LT LUC•18BL 7.5 15 ATSU01N222LT LUC•32BL LUB 32 10 20 ATSU01N232LT LUC•32BL Depending on the configuration of the chosen TeSys U starter, replace the • with A for standard, B for advanced, and M for multifunction. See page 18-28 for a complete list of available control units. Control voltage must be 24 Vdc. E231693 CCN NLDX LR96921 Class 3211 06 18-32 CP1G I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Starters TeSys™ GV2, GV3, and GV7 Manual Starter and Protector Refer to Catalog 2520CT0001 www.schneider-electric.us The GV family of products are 3-pole, horsepower rated, UL 508 listed manual starters. They include a manual disconnect, class 10 ambient-compensated thermal overload relay, and instantaneous, magnetic trip mechanism in one compact unit. Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220 A. The GV products may also be used in group motor installations in accordance with National Electric Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts and less wiring for installation when compared to conventional panel designs. The GV2P and GV3P products also have an additional UL 508 type E rating as a stand-alone, self-protected manual combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P, or GV3G66 for the GV3P. The GV2P and GV3P self-protected manual combination starters may also be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter construction. These products have a UL-listed short circuit current rating from 10–100 kA depending on application size and voltage. See the Schneider Electric website for more information. How to Order GV2ME To order a basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal setting from the table below. The thermal trip range and setting should be determined from the motor nameplate full-load current. Table 18.133: GV2, GV3 Group Motor Applications 3Ø GV2/3M push button GV2/3P rotary handle 120 V 208 V 240 V 120 V 208 V 240 V 480 V 600 V Max. Fuse or Catalog Catalog $ Price $ Price hp hp hp hp hp hp hp hp Circuit Breaker Number Number 0.11–0.16 — — — — — — — — 450 A GV2ME01a 159. GV2P01 212. 0.16–0.25 — — — — — — — — 450 A GV2ME02a 159. GV2P02 212. 0.25–0.40 — — — — — — — — 450 A GV2ME03a 159. GV2P03 212. 0.40–0.63 — — — — — — — — 450 A GV2ME04a 180. GV2P04 233. 0.63–1 — — — — — — — 0.5 450 A GV2ME05a 180. GV2P05 233. 1–1.6 — — 1/10 — — — 0.75 0.75 450 A GV2ME06a 180. GV2P06 233. 1.6–2.5 — 1/6 1/6 — 0.5 0.5 1 1.5 450 A GV2ME07a 180. GV2P07 233. 2.5–4 1/8 0.25 1/3 — 0.75 0.75 2 3 450 A GV2ME08a 180. GV2P08 233. 4–6.3 0.25 0.5 0.5 0.75 1 1.5 3 5 450 A GV2ME10a 180. GV2P10 233. 6–10 0.5 1 1.5 1 2 3 5 7.5 450 A GV2ME14a 180. GV2P14 233. 9–14 0.75 2 2 2 3 3 10 10 450 A GV2ME16a 224. GV2P16 278. 13–18 1 2 3 2 5 5 10 15 450 A GV2ME20a 224. GV2P20 278. 17–23 1.5 3 3 3 5 7.5 15 20 450 A GV2ME21a 224. GV2P21 278. 20–25 2 — — — 7.5 7.5 15 20 450 A GV2ME22a 224. GV2P22 278. 24–32 2 5 5 5 7.5 10 20 25 450 A GV2ME32 224. GV2P32 278. 9–13 0.5 — 1.5 — 3 3 7.5 10 — — — GV3P13 404. 12–18 0.75 — 2 — 5 5 10 15 — — — GV3P18 404. 17–25 1.5 — 3 — 5 7.5 15 20 — — — GV3P25 404. 23–32 2 — 5 — 7.5 10 20 25 — — — GV3P32 404. 30–40 3 — — — 10 — 25 30 — — — GV3P40 504. 37–50 — — 7.5 — 10 15 30 40 — — — GV3P50 504. 48–65 5 — 10 — 15 20 40 50 — — — GV3P65 504. a For spring terminals add 3 to the catalog number (for example, GV2ME013). GV2ME32 is not available with spring terminals. For ring terminals, add 6. Table 18.134: GV7 Maximum Horsepower Ratings GV3P Thermal Setting (A) 1Ø 115 V 230 V hp hp 12–20 — — 15–25 — — 25–40 — — 30–50 — — 48–80 — — 60–100 — — 90–150 — — 132–220 — — Specifications: page 18-36 Accessories: pages 18-34 to 18-35 Dimensions: pages 18-52 to 18-55 GV7RE20 Toggle Operator 3Ø 200 V hp — — — — — — — — 230 V hp 5 7.5 10 15 30 30 50 75 Standard Interrupt 460 V hp 10 15 30 30 60 75 100 150 575 V hp 15 20 30 40 75 100 150 200 Catalog Number GV7RE20 GV7RE25 GV7RE40 GV7RE50 GV7RE80 GV7RE100 GV7RE150 GV7RE220 High Interrupt $ Price 417. 417. 417. 417. 417. 456. 502. 502. Catalog Number GV7RS20 GV7RS25 GV7RS40 GV7RS50 GV7RS80 GV7RS100 GV7RS150 GV7RS220 $ Price 813. 813. 813. 813. 813. 891. 978. 978. Motor Protector Circuit Breakers Motor protector circuit breakers provide built-in thermal and magnetic protection. They are used in two-device motor feeder solutions to provide protection against short circuits, overloads, and phase imbalance. Table 18.135: Two-Device Solutions—Electronic Motor Protector Circuit Breakers with UL Ratings: H-Frame (150A), J-Frame (250 A), and L-Frame (600 A)b (refer to discount schedule DE2) Electronic Trip Unit Type E164864 CCN NLRV LR81630 Class 3211 05 © 2012 Schneider Electric All Rights Reserved Full Load G Interrupting J Interrupting Isd Ampere (x FLA) Cat. No. $ Price Cat. No. $ Price Rating (FLA) 30 14-25 5-13 x FLA HGL36030M38X 1608. HJL36030M38X 1658. 50 14-42 5-13 x FLA HGL36050M38X 1938. HJL36050M38X 1998. H-Frame 100 2.2 M 30-80 5-13 x FLA HGL36100M38X 2229. HJL36100M38X 2298. Standardc 150 58-130 5-13 x FLA HGL36150M38X 2701. HJL36150M38X 2785. J-Frame 250 114-217 5-13 x FLA JGL36250M38X 3105. JJL36250M38X 3201. 400 190-348 5-13 x FLA LGL36400M38X 6041. LJL36400M38X 6160. L-Frame 2.3 M 600 312-520 5-13 x FLA LGL36600M38X 8429. LJL36600M38X 8604. b Two-device solutions (these electronic motor protector circuit breakers include short circuit and overload protection): —1 contactor, plus —1 electronic motor circuit protector with a Micrologic 2.2 M c The standard trip unit offers Class 5, 10, and 20 and phase unbalance or phase loss protection. Sensor Rating Frame Trip Unit . I11 Discount Schedule L Interrupting Cat. No. HLL36030M38X HLL36050M38X HLL36100M38X HLL36150M38X JLL36250M38X LLL36400M38X LLL36600M38X $ Price 1812. 2191. 2506. 3057. 3253. 6468. 9156. 18-33 IEC CONTACTORS AND STARTERS GV2P21 with GV2GH7 installed 1Ø 18 Maximum Horsepower Ratings Thermal Setting (A) Starter Accessories TeSys™ GV2 and GV3 Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.136: Voltage Trips Only one trip or fault signaling contact can be installed per GV2/GV3 device. Description Characteristics Voltage Frequency 50 Hz 60 Hz 50 Hz 48 V 60 Hz 100–110 V 50/60 Hz 50 Hz 110–115 V 60 Hz 120–127 V 50 Hz 127 V 60 Hz Undervoltage or 200 V 50 Hz Voltage trips Shunt trip 200–220 V 60 Hz GV2 & GV3P (external mounting, 50 Hz 1 block right side only) 220–240 V 60 Hz 50 Hz 380–400 V 60 Hz 415–440 V 50 Hz 415 V 60 Hz 440 V 60 Hz 480 V 60 Hz 500 V 50 Hz 600 V 60 Hz a To order an undervoltage trip: replace the bullet ( •) with a U (for example, GVAU025). To order a shunt trip: replace the bullet ( •) with an S (for example, GVAS025). Catalog Numbera GVA•025 GVA•026 GVA•055 GVA•056 GVA•107 GVA•115 GVA•116 GVA•125 GVA•115 GVA•207 GVA•207 GVA•225 GVA•226 GVA•385 GVA•386 GVA•415 GVA•416 GVA•385 GVA•415 24 V GVAU116 $ Price 81.00 18 GVA•505 IEC CONTACTORS AND STARTERS Table 18.137: Auxiliary Contact Blocks Description GVAE11 Instantaneous auxiliary contacts GV2 + GV3P Fault signaling contact + instantaneous auxiliary contact GV2 + GV3P Mounting Location Max. No. of Blocks Frontbg 1 Left Hand Side 2 Left Hand Sided 1 Contact Type Sold in lots of Catalog Number N.O. or N.C.c N.O. + N.C. N.O. + N.O. N.O. + N.C. N.O. + N.O. N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. 1 10 1 1 1 1 1 1 1 GVAE1 GVAE11e GVAE20e GVAN11e GVAN20e GVAD1010 GVAD1001 GVAD0110 GVAD0101 21.80 35.70 35.70 35.70 35.70 54.00 54.00 54.00 54.00 GVAM11 35.70 Short circuit signaling contact Left Hand Side 1 SPDT 1 GV2 + GV3P b Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P. c Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted. d The GVAD is always mounted next to the starter. e For spring terminals, add 3 to the catalog number (for example, GVAE113). f One trip or one fault signaling can be fitted per GV3. g Cannot be used with GV2GH7 insulator. $ Price Table 18.138: Voltage Trips–Technical Data (GV2AU, GV2AS) Rated Voltage—660 Vac GVAD0101 h Model Inrush Sealed Pick-Up Voltage GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8—1.1 GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7—1.1 From the loss of voltage at the trip terminals to the opening of the starter contacts. Drop-Out Voltage 0.35—0.7 0.2—0.75 Operating Timeh 10—15 ms 10—15 ms Catalog Number GV3APN01 $ Price 136.00 GV3APN02 136.00 GV3APN04 149.00 GVAPK12 GVAPH03 GV3G264 GV3G364 19.00 30.00 25.00 45.00 GV3P•• GV3G66 18.00 GV3P•• LAD96570 12.00 GV3P•• GV3P••• GV2V03 15.00 Table 18.139: GV3P Accessories Accessory Through-the-door operating mechanism (Qty: 1) Angle bracket (Qty: 1) Hard bracket (Qty: 1) Set of 3-pole 115 A busbars (tap-offs: 2, pitch: 64 mm) Set of 3-pole 115 A busbars (tap-offs: 3, pitch: 64 mm) Cover “Larger Spacing” UL 508 type E (Only one cover required on supply side) IP 20 cover (Two covers required per starter) Padlocking device For use with up to 4 padlocks (not supplied) Ø 6 mm shank maximum Application / Use With NEMA 1, 12, Black with trip indication, for use with GV3P NEMA 1, 12, Red/Yellow, with trip indication, for use with GV3P NEMA 3R, 4, 4X Red/Yellow without trip indication, for use with GV3P Support shaft, for use with GV2P and GV3P — GV3P•• GV3P•• GVAN11 18-34 CP10 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Starter Accessories TeSys™ GV2, GV3, GV7 Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.140: Auxiliary Contact Blocks (auxiliary contact functions depends on location inside the device) Description Mounting Location Max. No. of Blocks Contact Type 2 per device N.O. + N.C. 1 per device N.O. + N.C. 1 per device N.O. + N.C. 2 per device N.O. + N.C. 1 per device N.O. + N.C. 1 per device N.O. + N.C. Catalog Number $ Price Standard Instantaneous Trip Indication Inside Device Fault Indication GV7AE11 35.70 GV7AB11 35.70 Low Level Instantaneous Trip Indication Inside Device Fault Indication GV7AC01 Table 18.141: Voltage Trips Max. No. of Blocks Voltage 48 Vac Undervoltage Trip Shunt Trip Inside Device 1 per device Inside Device 1 per device GV7RE20 GV7AU055 110–130 Vac 50/60 Hz GV7AU107 200–240 Vac 50/60 Hz GV7AU207 380–440/480 Vac 50/60 Hz GV7AU387 525 Vac 50 Hz GV7AU525 48 Vac 50 Hz GV7AS055 110–130 Vac 50/60 Hz GV7AS107 200–240 Vac 50/60 Hz GV7AS207 380–440/480 Vac 50/60 Hz GV7AS387 525 Vac Fault Indication Inside Device 1 per device Catalog Number 50 Hz 50 Hz $ Price 64.00 64.00 GV7AS525 24–130 GV7AD111 110–415 GV7AD112 72.00 Table 18.142: Wiring Accessories Description Catalog Number $ Price GV7AC021 19.70 each Sold in lots of 3 for GV7R•220i GV7AC022 24.90 each Terminal Extension Kit Increases center distance between phases to 45 mm GV7AC03 46.70 Terminal Shroud Kit Covers terminal connections for touch safe protection GV7AC01 41.90 Phase Barriers Provides maximum phase separation at connection points GV7AC04 31.10 Insulating Barriers Provides insulation between connectors and backplate GV7AC05 24.90 Connect to LC1F115–185 contactor GV7AC06 46.70 Connect to LC1F225–265 contactor GV7AC07 46.70 Black rotary operating handle with black legend plate (mounts directly on device) GV7AP03 86.00 Red rotary operating handle with yellow legend plate (mounts directly on device) GV7AP04 86.00 Conversion accessory to mount the device directly on panel door GV7AP05 14.00 Black rotary operating handle with black legend plate and extension kit (185–600 mm) GV7AP01 102.00 Red rotary operating handle with yellow legend plate and extension kit (185–600 mm) GV7AP02 102.00 GV7V01 14.00 Catalog Number $ Price Box Lugs GV7AD111 Application Sold in lots of 3 for GV7R•20–150i Phase Barriers, Bus Bars & Shrouds Busbars and Covers Operating Handles and Accessories GV7AS055 Padlocking device for toggle handle (max. 38 mm padlocks) i GV7AP03 Wire size: GV7AC021 = 14 to 3/0 AWG; GV7AC022 = 14 AWG to 350 kcmil. Table 18.143: Operating Handles For use with GV2, GV3, and TeSys U through-the-door operating mechanisms Accessory Description Operating Handle (Qty: 1) NEMA 1, 12, Black with trip indication GVAPB54 31.00 NEMA 1, 12, Red/Yellow, with trip indication GVAPR54 31.00 NEMA 3R, 4, 4X Red/Yellow without trip indication GVAPR65 37.00 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55 GVAPB54 GVAPR54 © 2012 Schneider Electric All Rights Reserved GV7AC021 GV7V01 I11 GV7AE11 Discount Schedule 18-35 IEC CONTACTORS AND STARTERS Mounting Location 18 Description Starter Accessories TeSys™ Manual Starters and Protectors LS1 Fuseholders Refer to Catalog 2520CT0001 www.schneider-electric.us • • • • • • 45 mm wide (same dimensions as GV2ME) Available with screw clamp and spring type terminals Mounts directly to LC1D09–D32 contactors (with use of GV2AF3 or GV2AF4) Meets application needs for fusible starter Uses GV2AE instantaneous contact blocks to open control circuits DIN rail mounted Table 18.144: LS1 Fuseholders Description Dimensions Fuse Type in. mm Spring terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Screw clamp terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Spring terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Screw clamp terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Auxiliary main pole adder aM, gG 0.39 x 1.5 10 x 38 a Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block. Use In Catalog Number US Markets US Markets European Markets European Markets European Markets LS1D303 LS1D30 LS1D323 LS1D32 LA8D324a $ Price 86. 86. 101. 86. 65. Table 18.145: Specifications 18 LS1D30 IEC CONTACTORS AND STARTERS Type LS1D30, LS1D303 Max. voltage 600 V 3 Phase Max. current Product approvals 30 A IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508, CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660 UL, CSA BV Protective treatment “TH” Ambient air temperature—operation -58 to 158o F (-50 to +70o C) Wiring Number of conductors and cross sectional area (c.s.a.) Conforming to standards LS1D32, LS1D323, LS1DT32 “TH” Solid cable 2 x 16–8 AWG (1–6 mm2) Flexible cable without cable end 2 x 14–8 AWG (1–6 mm2) Flexible cable with cable end 2 x 16–10 AWG (1–4 mm2) Resistance to mechanical impact conforming to IEC 60947-1 §7-1-6 0.5 J Tightening torque 15 in-lb (1.7 N•m) Sensitivity to phase failure No 30 90 90 30 Operating Positions Rated voltage—600 V 600 V Rated thermal current 25 A (GV2), 63 A (GV3) Mechanical life (varies by application) GV2: 100,000 operations Table 18.146: Environmental Specifications and Approvals Shock resistance Vibration resistance 30 g (conforming to IEC 600 68-2-27) 5 g (5 to 150 Hz) (IEC 600 68-2-26) –40 to 176 °F (–40 to +80 °C) for storage –4 to 140 °F (–20 to +60 °C) open operation –4 to 104 °F (–20 to +40 °C) enclosed operation 25 operations per hour Approximately 13 times the maximum thermal trip (non-adjustable setting) Ambient temperature Maximum operating rate Operating current of magnetic trip File LR81630 Class 3211 05 File E164864 CNN NLRV 18-36 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Starter Accessories TeSys™ GV2 Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.147: GV2 Mounting Accessories Description 7.5 mm compensation plate Application For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor. (supplied with GV1G02 connector) For screw mounting of GV2M Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor Interconnect GV2 and LC1D09 thru D32 Interconnect GV2 and LC1D09 thru D32 mounted on LAD31 To allow mounting of GV2M and GV2P on a common bus bar Mounting plate For mounting GV2ME or GV2P and contactor LC1D09 thru D32 Common mounting plate Adapter plate Combination block GV2GH7 Standard Pack b Catalog Number 1 GK2AF01 10 10 10 10 10 10 10 GV2AF02 GV2AF01 GV2AF3 GV2AF4 GV1F03 LAD31 LAD311 $ Price 21.60 7.10 14.00 3.20 3.20 5.40 6.20 12.30 Table 18.148: GV2 Cabling Accessories—Bus Bars Description Application Pitch 45 54 72 45 54 45 54 72 54 For feeding 2 GV2 starters 3-Pole, 63 A Bus Bar For feeding 3 GV2 starters For feeding 4 GV2 starters For feeding 5 GV2 starters Standard Pack b Catalog Number 1 GV2G245 1 GV2G254 1 GV2G272 1 GV2G345 1 GV2G354 1 GV2G445 1 GV2G454 1 GV2G472 1 GV2G554 $ Price 23.30 23.30 23.30 28.70 28.70 34.20 34.20 34.20 34.20 LAD31 Application Top feed for use with bus bars Terminal blocks Bottom feed, to be used with bus bars; can be fitted with GV1L3 current limiter Protective end cover To cover unused bus bar outlets 3-pole flexible connector For connecting a GV2 to an LC1D09 thru D25 contactor Conduit adapter (1/2" NPT) — Incoming line insulator For GV2P when used in UL 508 Type E applicationsa a Cannot be used with front-mounted auxiliary contact block. Standard Pack b Catalog Number 1 GV1G09 $ Price 34.20 1 GV2G05 34.20 5 10 1 10 GV1G10 GV1G02 GV2AK1 GV2GH7 3.60 14.30 16.20 15.00 Table 18.150: GV2 Other Accessories Description Visible isolation block—GV2P Current limiter—GV2M Through-the-door operating mechanism Angle bracket Hard bracket Application Front mounting, 3-pole visible isolation on incoming side of GV2P Increases interrupt capacity when attached to GV2M NEMA 1, 12, Black with trip indication, for use with GV2P NEMA 1, 12, Red/Yellow with trip indication, for use with GV2P NEMA 3R, 4, 4X, Red/Yellow without trip indication, for use with GV2P Support shaft, for use with GV2P — Standard Pack b Catalog Number 1 GV2AK00 1 GV1L3 1 GV2APN01 1 GV2APN02 $ Price 71.40 117.00 131.00 131.00 1 GV2APN04 144.00 1 1 GVAPK11 GVAPH02 19.00 30.00 Rating NEMA 1, IP41 IP55 NEMA 1, IP41 IP55 NEMA 1, IP41 IP55 Catalog Number GV2MC01 GV2MC02 GV2MP01 GV2MP02 GV2MP03 GV2MP04 $ Price 54.00 78.00 31.10 54.00 27.90 49.70 Standard Packb Catalog Number $ Price Table 18.151: GV2 Enclosures Description Enclosures for GV2M with or without accessories (maximum of 1 accessory on right and left) Enclosures are not UL or CSA listed. Mounting Surface mounting Flush mounting Flush mounting reduced width (max. of 1 accessory on right) Table 18.152: GV2 Enclosures Accessories LAD311 Description Padlocking device for GV2M (when padlocked, starter is automatically in Off position) Type — Spring return Mushroom head stop push button (40 mm, red) c GV2AF3 / GV2AF4 © 2012 Schneider Electric All Rights Reserved Key release (Ronis key no. 455) Turn to Release Latching / Padlockable Turn to Release Sealing kit For enclosures GV2MC01 and GV2MP01 110 V Green 110 V Red 110 V Orange 110 V White 220/240 V Green 220/240 V Red Pilot Light (neon) 220/240 V Orange 220/240 V White 380/440 V Green 380/440 V Red 380/440 V Orange 380/440 V White b Orders must specify multiples of quantities listed. c Supplied with IP55 sealing kit. Latching I11 Discount Schedule 1 GV2V01 26.90 1 1 1 1 10 10 10 10 10 10 10 10 10 10 10 10 10 GV2K011 GV2K021 GV2K031 GV2K04 GV2E01 GV2SN13 GV2SN14 GV2SN15 GV2SN17 GV2SN23 GV2SN24 GV2SN25 GV2SN27 GV2SN33 GV2SN34 GV2SN35 GV2SN37 35.90 104.00 52.00 117.00 18.00 26.90 18-37 18 Description IEC CONTACTORS AND STARTERS Table 18.149: GV2 Other Cabling Accessories Wiring, Communications, and Busbar System TeSys™ Contactors and Motor Protectors witH Spring Terminals Refer to Catalog 8502CT0101 www.schneider-electric.us Table 18.153: Splitter Boxes A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to create the desired line-up. Description APP2R4H1 Type of Control-Command Connection on Control System Side 50 A power splitter box No. of I/O per Starter — $ Price LAD322 LAD324 APP2R4H1 APP2R4H2 APP2R2E APP2R4E APP2R2AS APP2R4AS 52.00 93.00 124.00 124.00 124.00 124.00 124.00 124.00 1I/1O 2I/1O via module APP1C••• a — 2I/1O 1I/1O AS-Interface a Catalog Number 2 4 4 4 2 4 2 4 — 1 x HE10 8I/8O 1 x HE10 16I and 1 x HE10 8O 50 A power and control splitter box No. of Starters per Unit Connection to an APP1C••• module via APP2CX adapter (LAD35). Table 18.154: Power Connection Components for One Starter 18 LAD35 Description Kit Consists Of: Catalog Number Assembly and power connection kit One LAD31 plate for GV2ME and two LAD34 power connection modules LAD351 Reversing kit b One set of bus bars and one mechanical interlock LAD32 b To create a TeSys D reverser, use two LC1D contactors, one assembly and power connection kit, and one reversing kit. $ Price 21.00 20.70 Table 18.155: Power Connection Accessories for One Starter Description IEC CONTACTORS AND STARTERS Upstream terminal block (50 A max) Downstream terminal block (50 A max) Max. Connection Cross-Section 16 mm2 (6 AWG) 6 mm2 (10 AWG) Use Catalog Number Power supply for one or two power splitter boxes Connection of motor cables LAD3B LAD331 $ Price 83.00 5.00 Table 18.156: Control Connection Module for One Starter Description LAD3B Control connection module (integrating contact block GVAE20) c d LAD33 D-Line Coil Voltage 12–240 Vac or 24–125 Vdc 24–48 Vdc Type of Coil Control Relay Electromechanical c Without relay d Type of Starter Catalog Number Non-reversing Reversing Non-reversing Reversing APP2D1 APP2D2 APP2D1D APP2D2D $ Price 41.40 72.00 31.10 31.10 Relay supplied mounted on the front panel of the control connection. The use of TeSys D low consumption contactors is recommended. Table 18.157: Spare or Replacement Parts Type of Control-Command Connection on Control System Side No. of I/O per Starter — — Power connection module — 1 x HE10 8I/8O 1 x HE10 16I and 1 x HE10 8O — 1I/1O 2I/1O Control-command splitter box (single, for mounting on a power splitter box) Per module APP1C••• e Description Plate for mounting a GV2ME manual starter AS-Interface Replacement electromechanical relay (for control connection module) e Connection to an APP1C••• module via APP2CX adapter (LAD35). — 2I/1O 1I/1O — No. of Starters Sold in Lots of Catalog Number 1 1 1 4 4 2 4 2 4 1 10 10 10 1 1 1 1 1 1 10 LAD31 LAD311 LAD341 APP2R4H3 APP2R4H4 APP2R2C APP2R4C APP2R2A APP2R4A APP2ER $ Price 6.20 12.30 7.50 11.30 11.30 11.30 11.30 11.30 11.30 7.50 APP2D1• 18-38 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved Busbar Accessories TeSys™ AK5 Panel Busbar System Refer to Catalog 8502CT0101 www.schneider-electric.us The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tapoff are used. When using tap-offs, the nominal operating current of the bus bar (160 A @ 35°) must not be exceeded. Table 18.158: 160 A, 3-Phase Busbar System Maximum number of mounting plates Length Tap-off 1.42 in. AK5JB143 Standard Width Plate 36 mm 2.13 in. 54 mm Extension Plate 2.80 in. 71 mm in. mm Catalog Number $ Price 6 4 2 13.39 344 AK5JB143 210.00 9 6 3 17.64 452 AK5JB144 266.00 12 8 4 21.85 560 AK5JB145 286.00 15 10 5 26.05 668 AK5JB146 345.00 24 16 8 38.69 992 AK5JB149 393.00 27 18 9 42.90 1100 AK5JB1410 540.00 Table 18.159: Mounting Plate Tap-off (plugs into busbar mounted on AM1DL201 DIN rail) AK5PA231 mm Thermal Current Amperes 2.13 54 25 A 2.13 54 25 A 4.25 108 25 A Application GV2 with Catalog Number $ Price LUS or LUB 12 and 32 AK5PA231 98.00 contactor AK5PA232 120.00 AK5PA232S 206.00 reversing contactor Table 18.160: Bus Tap-off (plugs into busbar for wiring to a separately mounted device) Width AK5PA232S Length of Leads in. mm Thermal Current Amperes 1.42 36 32 A 9.84 250 AK5 PC33 23.00 1.42 36 32 A 39.37 1000 AK5 PC33L 37.80 Catalog Number in. $ Price mm Table 18.161: Extension Plates Used to mount wider components. Bolt to standard mounting plates (after DIN rails are removed). IEC CONTACTORS AND STARTERS Width in. Width mm 2.80 71 Application Catalog Number $ Price GV & Reversing contactor AK5PE27 26.30 $ Price Table 18.162: Mounting Rail (must be used for mounting plates with tap-offs) Depth Length mm mm Catalog Number 15 2000 AM1DL201 Description 75 mm Omega Rail 41.10 AM1DL201 Table 18.163: Approvals: IEC 439, UL, CSA, DNV, LROS File E161251 CCN NMTR © 2012 Schneider Electric All Rights Reserved File LR 89150 Class 6228-01 I11 Discount Schedule 18-39 18 AK5PC33 in. Dimensions TeSys™ D Contactors, AC Coil Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.164: TeSys D Contactors AC Control Circuits LC1D09 to D18 (3-pole) and LC1DT12 to LC1DT40 (4 pole) LC1D25 to D38 (3-pole) Minimum electrical clearance Minimum electrical clearance Minimum electrical clearance 1.73 44 Minimum electrical clearance b b b1 b b LA4 c .39 10 b1 18 c c2 c3 c3 c2 c3 a b .51 13 (LAD8) c .39 10 1.77 45 c .39 10 c1 c1 c2 c2 c3 c3 1.77 45 DC Coil AC coil, without add-on accessories 3.03 (77) DC coil — AC coil, with LAD4BB b 3.70 (94) AC coil, with LA4D*2 b 4.33 (110) a AC coil, with LA4DF, DT b 4.68 (119) a AC coil, with LA4DR, DW, DL b 4.96 (126) a AC coil, without cover or add-on blocks 3.30 (84) AC coil, with cover, without add-on blocks 3.38 (86) DC coil, without cover or add-on blocks 3.66 (93) DC coil, with cover, without add-on blocks 3.76 (95) AC coil, with LADN or C (two or four contacts) 4.60 (117) DC coil, with LADN or C (two or four contacts) 4.96 (126) AC coil, with LAD6K10 5.07 (129) DC coil, with LAD6K10 5.43 (138) AC coil, with LADT,R,S 5.39 (137) AC coil, with LADT,R,S and sealing cover 5.55 (141) DC coil with LADT,R,S 5.76 (146) DC coil with LADT,R,S and sealing cover 5.90 (150) Including LAD4BB Not applicable to devices with DC coils 3.89 (99) 3.14 (80) 3.36 (85) — — — 4.21 (107) 3.75 (95.5) 3.85 (98) 4.84 (123) a 4.30 (111.5) a 4.48 (114) a 5.19 (132) a 4.76 (120.5) a 4.84 (123) a 5.67 (139) a 5.0 (127.5) a 5.11 (130) a 3.30 (84) 3.30 (84) 3.54 (90) 3.38 (86) 3.38 (86) 3.62 (92) 3.66 (93) 3.66 (93) 3.89 (99) 3.76 (95) 3.76 (95) 3.97 (101) 4.60 (117) 4.60 (117) 4.84 (123) 4.96 (126) 4.96 (126) 5.19 (132) 5.07 (129) 5.07 (129) 5.31 (135) 5.43 (138) 5.43 (138) 5.66 (144) 5.39 (137) 5.39 (137) 5.62 (143) 5.55 (141) 5.55 (141) 5.78 (147) 5.76 (146) 5.76 (146) 5.98 (152) 5.76 (146) 5.76 (146) 6.14 (156) 3.89 (99) — 4.21 (107) 4.84 (123) a 5.19 (132) a 5.47 (139) a 3.54 (90) 3.62 (92) 3.89 (99) 3.97 (101) 4.84 (123) 5.19 (132) 5.31 (135) 5.66 (144) 5.62 (143) 5.78 (147) 5.98 (152) 6.14 (156) 3.34 (85) — 3.85 (98) 4.48 (114) 5.02 (129) 7.48 (190) 3.54 (90) 3.62 (92) — 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) 3.89 (99) — — — — — 3.54 (90) 3.62 (92) — 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) 3.58 (91) — — — — — 3.85 (98) 3.93 (100) — 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) 4.13 (105) — — — — — 3.85 (98) 3.93 (100) — 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) Table 18.165: AC Coil LC1D80004 (4P) 5.75* (LA1) 146 .51 13 (LA8) 6.50** (LA2, LA3, LA6 DK1) 165 2.95 (3P) 3.34 (4P) 85 75 4.92 125 5.00 127 5.00 127 5.20 (LA4 DA2, DE2) 132 5.59 (LA4 DF, DT) 142 5.91 (LA4 DM, DR, DW, DZ) 150 4.49 114 6.02* (LA1) 153 .51 13 (LA8) *except LA1DN10, DN01 = 136 ** +4 mm with lead sealing device 6.77** (LA2, LA3, LA6 DK2) 172 Minimum electrical clearance b1 b1 18-40 4.61 117 c c1 c c3 .51 13 (LA8) DT60A–DT80A D40008 in. (mm) in. (mm) in. (mm) 2.17 (55) 2.76 (70) 3.35 (85) — — 5.31 (135) with LA4 DB3 or LAD 4BB3 5.35 (136) — — with LA4 DF, DT 6.18 (157) — 5.59 (142) with LA4 DM, DW, DL 6.54 (166) — 5.91 (150) without cover or add-on blocks 4.65 (118) 4.65 (118) 4.92 (125) with cover, without add-on blocks 4.72 (120) 4.72 (120) — — — 5.47 (139) with LA4 D•2 c2 3.34 (3P) 3.78 (4P) 96 85 D40A–D65A LC1 a c1 .51 13 (LA8) *except LA1DN10, DN01 = 136 ** +4 mm with lead sealing device LC1 D40A–D65A (3P), LC1 DT60A–DT80A (4P) AC OR DC 0.47 12 5.51 (LA4 DA2, DE2) 140 5.79 (LA4 DF, DT) 147 6.18 (LA4 DM, DR, DW, DZ) 157 LC1D40, D50, D65 (3P), LC1D65004 (4P) 4.80 122 IEC CONTACTORS AND STARTERS c1 c1 c2 AC Coil b c .39 10 c1 0.49 12.5 (LAD 8N) a 0.49 12.5 (LAD 8N) with LAD N (1 contact) with LAD N or C (2 or 4 contacts) 5.91 (150) 5.91 (150) 5.79 (147) 6.42 (163) 6.42 (163) 6.26 (159) with LAD T, R, S 6.73 (171) 6.73 (171) 6.57 (167) with LAD T, R, S and sealing cover 6.89 (175) 6.89 (175) 6.73 (171) c2 with LAD 6K10 or LA6 DK c3 © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ D Contactors, DC Coil Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.166: DC Coil LC1D40, D50, D65 (3P), LC1D650004, (4P) LC1D80 (3P), LC1D800004(4P) Minimum electrical clearance 2.95(3P) 3.34(4P) 75 85 8.03* (LA1) 204 8.78d (LA6 DK2, LA2, LA3) 223 7.13 181 4.96 126 4.96 126 5.20 (LA4 DC3) 132 5.47 (LA4 DF, DT) 139 5.75 (LA4 DM, DR, DW, DZ) 146 6.73 171 .47 12 5.51 (LA4 DC3) 140 5.79 (LA4 DF, DT) 147 6.06 (LA4 DM, DR, DW, DZ) 154 Minimum electrical clearance .47 12 8.27* (LA1) 210 9.02d (LA6 DK3, LA2, LA3) 223 3.34 (3P) 3.78(4P) 85 96 *except LA1DN10, DN01 = 143 d + 4 mm with lead sealing device *except LA1DN10, DN01 = 136 d + 4 mm with lead sealing device D115 D1156 D150 D1506 c 5.12 (132) 4.53 (115) 5.12 (132) 4.53 (115) G (3-poles) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) G (4-poles) 5.12/5.67 (130/144) 5.12/5.67 (130/144) — — = c = G = IEC CONTACTORS AND STARTERS LC1 5.12 130 6.22 158 = LC1D115, D150 6.61c (LA2, LA3) 168 6.85 (LA4D•2, D•3) 174 7.28 (DF, DT) 185 7.40 (DM, DR, DW, DL) 188 LA4 6.22 158 LA8 c LC1 C A D115, D150 D115004 D1156, D1506 D1150046 5.12 (132) 5.12 (132) 4.53 (115) 4.53 (115) 4.72 (120) 6.10 (155) 4.72 (120) 6.10 (155) 18 LC1D115, D150 a 5.91q (LA1) 150 6.10 (LA6-DK20) 155 a b With 2 or 4 contacts. + 4 mm with sealing cover. LR9D solid-state overload relay Direct mounting beneath contactors LC1D115 and D150 5.20 132 d 35 mm DIN rail dimensions AM1DP200 and DR200 d 0.10 (2.5) © 2012 Schneider Electric All Rights Reserved 10.04 255 4.72 120 AM1DE••• and ED••• .41 (10.5) 5.20 132 d 35 mm DIN rail dimensions AM1DP200 and DR200 d 0.10 (2.5) Note: All dimensions are in Inches (mm). 5.35 136 6.85 174 5.91 150 7.44 189 10.51 267 LR2D4 bimetallic overload relay Direct mounting beneath contactors LC1D115 and D150 4.72 120 AM1DE••• and ED••• .41 (10.5) 18-41 Dimensions TeSys™ F Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us All dimensions shown in mm. To convert to inches, divide by 25.4. LC1F115 to F330 S a Table 18.167: LC1F115–F330 Dimensions s1 = F115 X1 M b b2 c = X1 (see Table 18.168) L 18 c a F150 F185 F265 F330 LC1 Q P Q1 P a f = J J1 IEC CONTACTORS AND STARTERS b1 = Protective cover Type LA9F70•. G1 = = G Z Y 34343434Pole Pole Pole Pole Pole Pole Pole Pole a 163.5 200.5 163.5 200.5 168.5 208.5 201.5 243.5 b 162 162 170 170 174 174 203 203 b1 137 137 137 137 137 137 145 145 b2 265 265 301 301 305 305 370 370 c 165b 165b 165b 165b 176 176 207 207 f 131 131 131 131 130 130 147 147 G 106 143 106 143 111 151 142 190 G1 80 80 80 80 80 80 96 96 J 106 106 106 106 106 106 106 106 J1 120 120 120 120 120 120 120 120 L 107 107 107 107 113.5 113.5 141 141 M 147 147 150 150 154 154 178 178 P 37 37 40 40 40 40 48 48 Q 29.5 29.5 26.5 26 29 29 39 34 Q1 60 60 57.5 55.5 59.5 59.5 66.5 66.5 S 15 15 20 20 20 20 25 25 S1 27 27 34 34 34 34 38 38 Y 44 44 44 44 44 44 38 38 Z 13.5 13.5 13.5 13.5 13.5 13.5 21.5 21.5 b +6 mm with time delay block (for F115 and F150). c Optimal terminal shroud f = minimum distance required for coil removal. 3Pole 213 206 145 375 219 147 154.5 96 106 120 145 181 48 43 74 25 44.5 38 20.5 4Pole 261 206 145 375 219 147 202.5 96 106 120 145 181 48 43 74 25 44.5 38 20.5 Table 18.168: LC1F115–F330 Voltage 220/380 V 415/440 V 500 V 660 V 1000 V LC1F115, F150 20 25 30 40 20 LC1F185 20 25 30 40 30 LC1F265 20 25 40 50 40 LC1F330 25 35 40 50 50 X1: Minimum clearance according to the operational voltage and the breaking capacity. Table 18.169: LC1F400–F500 Dimensions LC1F400 to F500 LC1 2.20 56 S 1.49 38 X1 = M10 X 30 dia. M b2 = X1 (see Table 18.170) b 8.23 209 e Q L P c Q1 P a f = 7.09 180 F500 2-Pole 233 238 400 226 141 80 66 120 170 156 210 39.5 146 208 55 76 102 30 3-Pole 233 238 400 226 141 80 66 120 170 156 210 39.5 146 208 55 46 77 30 4-Pole 288 238 400 226 141 140 66 175 230 156 265 34.5 146 208 55 46 77 30 Table 18.170: LC1F400–F500 Voltage 220/230 V 415/440 V 500 V 660 V 1000 V LC1F400 30 40 40 50 60 LC1F500 40 45 50 60 60 X1: Minimum clearance according to the operational voltage and the breaking capacity. = = 4.7 120 = 8 X 8.5 dia. F400 2-Pole 3-Pole 4-Pole a 213 213 261 b 206 206 206 b2 375 375 375 c 213 213 213 f 119 119 119 Gd 80 80 80 G min. 66 66 66 G max. 102 102 150 G1d 170 170 170 G1 min. 156 156 156 G1 max. 192 192 240 J 19.5 19.5 67.5 L 145 145 145 M 181 181 181 P 48 48 48 Q 69 43 43 Q1 96 74 74 S 25 25 25 d Supplied e Protective cover f = Minimum distance required for coil removal. G .92 23.5 G1 Dual Dimensions: 18-42 J INCHES Millimeters © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ F Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.171: LC1F Dimensions LC1F630 and LC1F800 2.52 64 1.57 40 2.83 72 Dual Dimensions: 6 x M12 x 45 INCHES Millimeters c 7.09 180 10.39 264 18.28 464 = = X1 11.02 280 11.97 304 X1 = = 4 x Dia. 10.5 mm 3.15 80 G supplied G min. G max. J1 Q Q1 LC1F630 * = minimum distance required for coil removal. c Protective terminal cover. in. mm in. mm in. mm in. mm in. mm in. mm in. mm 2P 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 4.02 102 5.00 127 3P 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 2.36 60 3.50 89 4P 15.31 389 9.45 240 5.91 J1 7.13* 181 a a G 2.38 60 Q1 150 10.83 275 2.70 68.5 IEC CONTACTORS AND STARTERS 7.76 197 3.15 80 2.36 60 3.50 LC1F780, F7804 X1:Minimum clearance according to the operational voltage and the breaking capacity. 89 Voltage (V) 380 415/440 X1 in mm 60 60 500 660 1000 60 70 80 12 x M14 x 45 1.02 26 = X1 15.74 400 13.70 348 17.08 434 11.02 280 .86 22 18 X1 = 2.36 60 1.02 26 9.84 250 Q 6.10 155 6.50 165 9.84 250 6.30 160 7.52 191 27.64f 702 7.20* 183 380 415/440 660 1000 X1 in mm 90 100 120 120 7.20* 183 a Overall length (4 poles) *minimum distance required for coil removal. LC1F7804 mounting 5.00 127 5.00 127 LC1F780 mounting 7.52 191 f Overall length (3 poles) X1: Minimum clearance according to the operational voltage and the breaking capacity. Voltage (V) 6.30 160 33.93a 862 8 x Dia. 10.5 mm 5.00 127 5.00 127 7.09 180 7.09 180 6 x Dia. 10.5 mm 3.50 90 9.45 240 © 2012 Schneider Electric All Rights Reserved 9.45 240 5.20 132 3.50 90 9.45 240 7.48 190 9.45 240 4.00 102 18-43 Dimensions TeSys™ D Reversing Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.172: Reversing Contactor Dimensions LC2D09–D32 LC2DT20–DT60 2 x LC1DT20–DT60 2 x LP1D40, D65, D80, D95 = .31 8 G1 = = = G = e2 c 3.94 100 b 2.36 60 b 4.33 110 2.76 70 2xM0.16 2xM4 e1 6xØ0.26 6xØ6.5 = a b c G in. (mm) 3.34 (85) 3.58 (91) in. (mm) 3.54 (90) 3.85 (98) in. (mm) 3.14 (80) 3.14 (80) a LC2 or 2 x LC1 b c G e1 e2 a 1.57 40 G = G1 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) D40 to D65 7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97) D80 and D95 8.14 (207) 5.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111) c, e1 and e2: includes cabling. LC2D115 and D150 2 x LC1D115 and D150 Panel mounted with 1/4 in. screw = 5.12 130 6.22 158 = e1 Dimensions shown in millimeters (mm ÷ 25.4 = inches) e2 IEC CONTACTORS AND STARTERS in. (mm) DT20 and DT25 3.54 (90) DT32 to DT60 3.54 (90) c, e2: includes cabling. 1.57 40 .51 13 18 a LC2 or 2 x LC1 = e2 c = G c LC2 or 2 x LC1 (3-pole) D115, D150 LC2 or 2 x LC1 (4-pole) D115 c, e1 and e2 includes cabling = a a c e1 e2 G 266 a 334 148 c 148 56 e1 — 18 e2 60 242/256 G 310/324 NOTE: For dimensions of TeSys F reversing contactors, please refer to catalog 8502CT9901. 18-44 © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ D Overload Relays Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.173: TeSys D Overload Relay Dimensions LRD-01-35 Independent mounting on 50 mm centers or on rail AM1DP200 or DE200 1.38 35 Independent mounting on 110 mm centers .39 10 1.81 46 = = LAD7B106 1.77 45 = 4.33 110 4.92 125 .08 2 .24 6 3.15 80 .20 5 1.50 38 1.97 50 3.15 80 .59 15 LAD7B106 = Remote tripping or electrical reset LAD703 a DX1AP25 3.54 90 2xØ0.26 2xØ6.5 LRD, LR2D and LR9D Reset by flexible cable LA7D305 and LAD7305 Mounting with cable straight Mounting with cable bent e Can only be mounted on RH side of relay LRD-01 to 35 e c: up to 21.6 in. (550 mm) e: up to 0.79 in. (20 mm) LRD3tt Beneath LC1DttA contactor Separate mounting LC1D pp A 2.17 55 4.57 116 4.84 123 2.17 55 LA7-D2064 2xØ0.18 2xØ4.5 3.54 90 0.31 8 0.67 17 3.86 98 LR2D1, LR3D1 Separate mounting at 110 mm (4.33 in.) centers d = 2xØ0.18 2xØ4.5 0.51 0.87 13 22 LR2D2, LR3D2 Separate mounting at 110 mm (4.33 in.) centers 2.24 57 = = LA7D2064 = 1.81 46 = DX1AP25 2.17 55 1.57 40 = 1.97/2.56 50/65 = 1.97/2.56 50/65 0.16 4 1.48 43.5 3.11 79 1.77 45 1.38 35 1.71 43.5 = LA7-D1064 LR2D2, LR3D2 Separate mounting at 50 mm (1.97 in.) centers or on AM1DP200 or DE200 rail 0.12 3 LR2D1, LR3D1 Separate mounting at 50 mm (1.97 in.) centers or on AM1DP200 or DE200 rail d LA7D1064 DX1AP25 = Mounting Holes 1.97 50 = = 4.33 110 4.92 125 4.33 110 4.92 125 1.97 50 Mounting Holes 4.25 108 © 2012 Schneider Electric All Rights Reserved 18 3.43 87 7.28 185 3.86 98 M10x0.04 M10x1 = a c IEC CONTACTORS AND STARTERS 1.26 32 2 x Ø6.5 mm Screws 4.25 108 2 x Ø6.5 mm Screws 18-45 Dimensions TeSys™ D Thermal Overload Relays Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.174: TeSys D Thermal Overload Relay Dimensions, in. (mm) LRD-01-35 Direct mounting beneath contactors with screw 18 LC1• b c LRD-013-353 Direct mounting beneath contactors with spring terminal connections LC1• b D09–D18 D25–D38 4.84 (123) 5.39 (137) See Catalog 8502CT9901 pages 122, 123. D093–383 4.84 (123) See Catalog 8502CT9901 pages 122, 123. c IEC CONTACTORS AND STARTERS LRD-3••• Direct mounting beneath contactors LC1-D40 to D95 and LP1-D40 to D80 AM1• DL201 d LRD4••• Direct mounting beneath contactors LC1D115 and D150 a AM1DL200 and DR200 AM1DE200 and ED••• d 0.10 (2.5) 0.41 (10.5) For additional specifications and selection information, see catalog 8502CT9901 18-46 0.28 (7) DL200 0.67 (17) b g(3P) g(4P) LC1D80 LC1D95 AC Control Circuit 4.55 (115.5) 4.88 (124) 3.03 (76.9) 4.55 (115.5) 4.88 (124) 3.03 (76.9) c e 0.37 (9.5) 0.37 (9.5) 0.87 (22) — LC1D40, LP1D40 LC1D50 LC1D65, LP1D65 LC1D80, D95, LP1D80 DC Control Circuit 4.37 (111) 6.93 (176) 2.85 (72.4) 4.37 (111) 6.93 (176) 2.85 (72.4) 4.37 (111) 6.93 (176) 2.85 (72.4) 4.55 (115.5) 7.06 (179.4) 3.03 (76.9) 0.18 (4.5) 0.18 (4.5) 0.18 (4.5) 0.37 (9.5) 0.51(13) — 0.51(13) 0.87(22) LR9D Direct mounting beneath contactors LC1D115 and D150 d AM1DP200 and DR200 0.10 (2.5) AM1DE200 and ED••• 0.41 (10.5) © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ F Overload Relays Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.175: TeSys F Overload Relay Dimensions LR9F5•71 LR9F5•57, F5•63, F5•67, F5•69 Common side view 1.97 50 LR9F7•75, F7•79, F7•81 LR9F7•81 Common side view (for mounting beneath LC1F630) P1 P2 Ø11 1.18 30 4xØ5.5 2.36 60 Ø13 3.15 80 2.44 62 1.57 40 3.23 82 5.39 137 .24 6 .87 22 2.76 70 5.94 151 7.44 189 .98 25 2.05 52 2.60 66 9.02 229 1.77 45 4.29 109 2.05 52 2.60 66 .24 6 LR9F7•75 LR9F7•79, F7•81 Terminal shroud LA9-F70• 7.87 200 .79 20 3.15 80 4xØ5.5 .79 20 18 1.65 42 .55 14 5.04 128 c 2.80 71 4.53 115 1.85 .11 47 3 Terminal shroud LA9F70• 6.5 x 13.5 for LR9F5•57 and 8.5 x 13.5 for LR9F5•63, F5•67, F5•69 cf 1.97 50 1.57 40 2.99 76 2.80 71 2.36 60 2.99 76 4xØ5.5 4.53 115 a b 1.97 50 1.97 50 1.57 40 bc IEC CONTACTORS AND STARTERS .98 25 4.72 120 3.78 96 Ø11 1.89 48 .22 6 1.89 48 .22 6 2.24 57 1.77 45 .11 3 3.98 101 4.88 124 aq 1.57 40 P1 48 55 P2 48 55 3.03 77 3.03 77 Direct mounting beneath reversing contactors or star-delta contactors b H3 H3 Direct mounting beneath contactor LC1F 7.60 193 b H4 H2 H2 H1 LA7F40 e LA7F40p Bus Bar Busbar d LC1 contactors F115 F150 F185 F225 d e With LR9 relays F5•57, F5•63, F5•67, F5•69 F5•57, F5•63, F5•67, F5•69 F5•57, F5•63, F5•67, F5•69 F5•71 F7•75, F7•79 F265 F5•71 F7•75, F7•79 F330 F7•75, F7•79 F400 F7•75, F7•79, F7•81 F500 F7•75, F7•79, F7•81 F630 F7•81 Relay mounting plate, see page 18-16. Connection accessories, see page 18-16. © 2012 Schneider Electric All Rights Reserved b 240 246 250 273 308 279 314 317 317 346 510 H1 30 30 30 40 50 40 60 60 60 70 110 H2 76 76 76 76 108.8 76 108.8 108.8 108.8 108.8 108.8 H3 120 120 120 120 120 120 120 120 180 180 180 LC1 contactors F115 F150 F185 F225 F265 F330 F400 F500 F630 With LR9 relays F5•57, F5 • 63, F5•67, F5•69 F5•57, F5•63, F5•67, F5•69 F5•57, F5•63, F5•67, F5•69 F5•71 F7•75, F7•79 F5•71 F7•75, F7•79 F7•75, F7•79 F7•75, F7•79, F7•81 F7•75, F7•79, F7•81 F7•81 b 279 283 285 319 360 332 363 364 364 390 509 H4 60 60 60 80 100 90 100 100 100 110 120 H2 76 76 76 76 108.8 76 108.8 108.8 108.8 108.8 108.8 H3 120 120 120 120 120 120 120 120 180 180 180 18-47 Dimensions TeSys™ D Combination and Non-combination Starters Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.176: TeSys D Combination Starter Dimensions, Reversing and Non-Reversing NEMA 1 D09–25 (FVNR) D09–40 (FVR); D32-40 (FVNR) 10.00 254 5.00 7.50 127 191 3.00 7.50 76 191 18.00 203 419 16.50 14.02 R 318 12.52 18 18 356 .69 457 8.00 IEC CONTACTORS AND STARTERS R Provision for 1/4" Screw Provision for 1/4" Screw NEMA 12/3R D09–25 (FVNR) D09–40 (FVR); D32–-40 (FVNR) 10.00 254 5.00 7.75 127 197 8.00 3.00 7.75 457 18.00 499 19.63 356 14.00 378 18.88 197 397 15.63 14.88 76 480 203 R R Provision for 1/4" Screw Provision for 1/4" Screw Table 18.177: Non-Combination Starter Dimensions A 13 .50 Non-Combination Starters .75 E B 19 J K C R F 56 14 D/2 D G H Provision for 1/4" Screw Type 1 Non-Reversing Reversing D09-32 — D40-65 D09-32 D80 D40-80 Note: All dimensions in inches. 18-48 A 6.77 8.66 10.63 B 10.04 10.83 13.98 C 6.25 7.21 7.21 D 5.38 7.25 9.22 E 9.00 9.75 12.94 F G 1–1.25 0.5–0.75 1.25–1.5 0.5–0.75 1.25–1.5 0.5–0.75 Type 12/3R H — 1–1.25 1–1.25 J 1–0.25 1–0.25 1–1.25 K 0.5–0.75 0.5–0.75 0.5–0.75 D 5.38 5.38 5.38 E 11.37 12.15 15.30 © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ K Contactors Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.178: TeSys K Contactor Dimensions LR2K Direct mounting under the contactor Separate mounting with LA7-K0064 terminal block on 35 mm rail (AM1DP200 or AM1DE200) 1.38 35 4.57 116 2.28 58 2.56 65 3.15 80 1.50 38 4 x Ø4 1.97 50 .31 8 1.77 45 1.77 45 13 A1 13 5 3 Wiring Scheme 1 Three-phase 2.95 75 3.09 (DP200) 78 3.38 (DE200) 86 A H 95 Internal Links 96 IEC CONTACTORS AND STARTERS 14 A2 6 4 A2 96 Test LC1, LP1, LP4K Mini-contactors On baseplate 96 98 6 95 4 2 97 A1 – KM1 Reset/Stop LC2, LC8, LP2, LP5K Reversing mini-contactors On baseplate 8 x Ø4 1.97 50 2.28 58 1.38 35 1.77 45 2.24 57 2.24 57 1.22 31 3.15 80 3.54 90 On AM1DP200 or DE200 rail (35 mm) 2.28 58 2.28 58 On AM1DP200 or DE200 rail (35 mm) 2.24 57 2.24 57 1.77 45 3.54 90 On printed circuit board for reversing contactors or 2 mini-contactors side-by-side On printed circuit board 1.77 45 .34 A1 9 A1 2.28 58 1.97 50 2.05 52 2.28 58 10 x Ø.051 10 x Ø1.3 .34 9 A1 .34 9 A2 20 x Ø.051 20 x Ø1.3 A2 LA2KT Electronic time delay contact blocks 1.97 50 2.05 52 1.22 31 LA1-K 2.28 58 4 x Ø4 1.97 50 LA1-K 1.77 45 1.77 45 A2 On mini-contactors or reversing mini-contactors 1.34 34 Dual Dimensions: © 2012 Schneider Electric All Rights Reserved 2.28 58 1.06 27 LA2-KT 1.50 38 INCHES Millimeters 1.34 34 2.24 57 18-49 18 2 97 95 96 95 O 98 5 3 6 4 2 1 14 – KM1 Dimensions TeSys™ U Motor Starters Refer to Catalog 8502CT0201 www.schneider-electric.us Table 18.179: TeSys U Starter Dimensions Starter Controllers Reversing Rail Mounting Screw Mounting 126 4.96 1.18 Ø4 .15 1.14 163 6.42 224 8.82 73 2.87 154 6.06 X1 45 X2 1.77 Screw Mounting 29 30 X2 135a 5.31 Rail Mounting 135a 5.31 120/125 4.72/4.92 X1 126 4.96 Ø4 .15 233 9.17 Non-Reversing 45 1.77 18 Note: Minimum electrical clearance: X1: 35 mm for Ue = 440 V; and 70 mm for Ue = 500 and 690 V X2: 0 a Maximum depth (with Modbus™ communication module) Reversing Block for Mounting Separately from Power Base Rail Mounting Screw Mounting 104 4.09 115 4.53 IEC CONTACTORS AND STARTERS Ø4 .15 113 4.45 113 4.45 45 1.77 36 1.41 154 6.06 93 3.66 Limiter Disconnector LUALB1 135a 5.31 a 45 1.77 Maximum depth (with Modbus communication module) Door interlock Mechanisms LU9AP00 Door Cut-out = = 54 2.12 55 2.16 230 9.06 Ø43 1.69 = = 54 2.12 4xØ3.5 .13 Dual Dimensions: 508 20.01 18-50 11.5 .45 8 .31 INCHES Millimeters Ø7 .27 © 2012 Schneider Electric All Rights Reserved Dimensions Altistart™ U01 and TeSys™ U Soft Starters Refer to Catalog 8502CT9901 www.schneider-electric.us Table 18.180: Altistart U01 and TeSys U Soft Starters TeSys U Combination (non-reversing or reversing power base) and ATSU01N2206LT to ATSU01N212LT Side-by-side mounting TeSys U Combination (non-reversing power base) and ATSU01N212LT Mounting on (35mm) rail with VW3 G4104 connector 135 5.31 99 3.9 284 11.18 150 5.91 124 4.88 154 6.06 72.2 2.84 45 1.77 IEC CONTACTORS AND STARTERS 9 0.354 9 0.354 TeSys U Combination (non-reversing power base) and ATSU01N222LT to ATSU01N232LT Mounting on (35mm) rail with VW3G4104 connector TeSys U Combination (non-reversing or reversing power base) and ATSU01N222LT to ATSU01N232LT Side-by-side mounting 135 5.31 99 3.9 154 6.06 18 72.2 2.84 45 1.77 314 12.36 170 6.69 9 0.354 VW3G4104 Power Connector 46.6 1.83 9 0.354 44.8 1.76 6 0.24 28 1.10 20 0.79 © 2012 Schneider Electric All Rights Reserved 18-51 Dimensions TeSys™ Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.181: TeSys GV2 and GV3 Manual Starter and Protector Dimensions GV2AD, AM, AN, AU, AS, AX GV2AE Block GV2AD, AM, AN Block GV2AU, AS, AX Mounting of GV2M On 35 mm rail C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm) C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm) 16 44 .63 1.73 66 2.60 44.5 1.75 44.5 1.75 9.3 .37 GV2P 9.3 .37 81 3.19 18 .71 c GV2AD, AM, AN, AU, AS, AX 14 .55 On 35 mm rail C = 98.5 mm (3.88") on AM1DP200 (35 x 7.5 mm) C = 106 mm (4.17") on AM1DE200, ED200 (35 x 15 mm) 98 3.86 32 1.26 = Block GV2AD, AM, AN Block GV2AU, AS, AX Mounting of GV2P 44.5 1.75 9.3 .37 9.3 .37 81 3.19 18 .71 44.5 1.75 GV2AF4 + LAD31 GV2P + GV2GH7 GV2P + GV2GH7 + TeSys D contactor for UL 508 Type E application b b c1 45 1.77 c c1 d1 3.6 (91.4) 3.6 (91.4) 3.8 (96.52) 3.8 (96.52) 44 1.73 45 1.77 c 13.5 .53 for UL 508 Type E application 103 4.07 Combination GV2P + TeSys D range contactor d GV2ME + b c1 c d1 d LC2D09 to D18 7.4 (188.6) 3.6 (92.7) 3.9 (98.2) 3.9 (98.3) 4.1 (103.8) LC2D25 and D32 7.8 (199) 3.9 (99) 4.11 (104.5) 3.9 (98.3) 1.4 (103.8) GV2P + b c1 c — — • LC2D25 and D32 7.9 (199.5) 4.6 (116.8) 4.8 (122.3) — — Flush mounting enclosure GV2MP0 = a LC2D09 to D18 6.61 (168.1) 4.6 (116.8) 4.8 (122.3) — — • (bracket cut-out) Surface mounting enclosure GV2MC0 130 5.12 = 84 3.31 93 3.66 a = 13 0.51 = 1...6 /0.04...0.24 84 3.31 = 93.5 3.68 106.5 4.19 = 71 2.8 6.5 0.25 92.8 3.65 4 knock-outs for 16 mm plastic cable glands or no. 16 conduit. GV2 MP01, MP02 MP03, MP04 18-52 b b1 = 2xØ5.3x6.3 147 5.79 IEC CONTACTORS AND STARTERS Combination GV2ME + TeSys D range contactor c 191 7.50 50 1.97 82 3.23 = 18 26 1.02 15 .59 44.5 1.75 = 44.5 1.75 45 1.77 61 2.40 89 3.50 GV2AK00 84 3.31 11 .43 44.5 1.75 = 89 3.5 45 1.77 = 15 .59 10 .39 GV2M b in. 5.51 5.24 b1 mm 140 133 in. 5.00 4.61 mm 127 117 © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.182: TeSys GV2 and GV3 Manual Starter and Protector Dimensions (cont’d) GV2M with GK2AF01 and LC1K GV2M with GV2AF01 and LC1K GV2M with GV2AF01 and LC2K Adapter Plate GK2AF01 5 .2 35 1.38 Dimensions (mm) 4xØ3.5 Ø43 0.14 1.7 50/60 1.97/2.36 = 54 2.13 = = 54 2.13 5.2 0.21 = = Sets of bus bars with terminal block GV1G09 Sets of bus bars GV2G245, GV2G254, GV2G272 p l 1.2 30 l 18 2.5 63 .71 18 .12 3 35 1.38 13 0.51 35 1.38 80 3.15 Sets of bus bars, GV2G445, GV2G454, GV2G472 with terminal block GV2G05 7.5 mm height compensation plate GV1F03 4.2 .17 = 1.5...5/0.06...0.20 min.=150 max.=290 5.91 11.42 35 1.38 GV2M on panel with GV2AF02 adapter plate Door cut-out 7 .276 53 2.1 54 2.13 9.5 .37 39 1.54 Mounting external operator GV2AP0• 65 2.56 24 .94 90 3.54 IEC CONTACTORS AND STARTERS 45 1.77 79 3.11 105 ± 5 4.13 ± .2 135 5.31 45 1.77 45 1.77 152 6.0 152 6.0 55 2.17 Ø5.5 .22 1.8 45 GV2G445 GV2G454 GV2G472 0.16 x 1.8 in. (4 x 45 mm) 0.16 x 2.1 in. (4 x 54 mm) 0.16 x 1.8 in. (4 x 45 mm) I 7.0 in. (179 mm) 8.1 in. (206 mm) 10.2 in. (260 mm) P 1.8 in. (45 mm) 2.1 in. (54 mm) 2.8 in. (72 mm) GV2G245 GV2G254 GV2G272 GV2G354 I 3.5 in. (89 mm) 3.9 in. (98 mm) 4.6 in. (116 mm) 6.0 in. (152 mm) 0.08 x 1.8 in. (2 x 45 mm) 0.08 x 2.1 in. (2 x 54 mm) 0.08 x 2.8 in.(2 x 72 mm) 0.12 x 2.1 in. (3 x 54 mm) GV3P Dimensions Mounting on rail AM1 DE200 or AM1 ED201 X1 (1) 64 64 132 68 68 (2) 144 55 X1 136 9 X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V; 50 mm for Ue < 690 V Mounting on panel, using M4 screws 18 Blocks GV AN••, GV AD••, GV AM11 Block GV3 AU•• and GV3 AS•• Mounting on pre-slotted mounting plate AM1PA 16 183 3xØ4 136 37,5 137,5 137,5 AF1 EA4 136 18,7 18,7 Note: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional sales office. © 2012 Schneider Electric All Rights Reserved 18-53 Dimensions TeSys™ GV7 Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.183: TeSys GV7 Manual Starter and Protector Dimensions 1 GV7R Panel Mounting Flush Mounting Side by Side 4.25 108 = = 4.25 108 = = 4.92 125 1.85 3.0 47 76 = 2xØ0.24 2xØ6 = 1.14 29 3.46 88 == 1.14 29 3.27 83 Minimum Clearance 18 Painted or insulated metal plate, insulation or insulated bar U <440V 440 V < U < 600 V = = 4.25 108 x1 x2 in. (mm) 0 (0) 0.20 (5) 0.39 (10) in. (mm) 1.18 (30) 1.38 (35) 1.38 (35) 0.79 (20) 1.38 (35) x2 1.38 1.38 1.38 35 35 35 x1 x1 IEC CONTACTORS AND STARTERS U > 600 V x2 Bare metal plate Note: Minimum distance between 2 units mounted side by side = 0. 21 22 24 82 84 81 92 94 91 11 14 12 Add-on Auxiliary Contacts, GV7AE11, GV7AB11 5/L3 3/L2 1/L1 Motor Controllers GV7R 6/T3 4/T2 2/T1 Note: A self-adhesive label, supplied with the contact, can be affixed to the front face of the starter to allow personalized marking according to the function of the contact or contacts. GV7AS••• GV7AD111, AD112 50 ms 98 97 50 ms 13 97 D4 C2 97 D1 C1 GV7AU••• 50 ms 21 23 98 14 98 – KA1 18-54 A1 – KM1 A2 – KA1 A2 – KA1 B1 A1 22 24 – KA1 © 2012 Schneider Electric All Rights Reserved Dimensions TeSys™ GV7 Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.184: TeSys GV7 Manual Starter and Protector Dimensions (cont’d) GV7AC03 Spreaders 1.61 41 4.49 114 1.77 1.77 45 45 1.18 30 Smooth Terminals a Connectors Z 0.75 19 Z X X IEC CONTACTORS AND STARTERS X a (in./mm) 0.77/19.5 0.85/21.5 • • GV7R GV7R 220 2.76 70 2.76 70 Z 0.41 10.5 Cabling GV7AP03, GV7A04 60 0 1.10 28 6.10 155 © 2012 Schneider Electric All Rights Reserved 4.76 121 3.58 91 2.17 55 1.42 36 1.14 29 3.5 89 = = 18 DD 73 1.77 2.87 45 I 60 Flush Mounting 1.85 3.0 47 76 Direct Rotary Handle 3.82 97 18-55 Dimensions TeSys™ GV7 Manual Starters and Protectors Refer to Catalog 2520CT0001 www.schneider-electric.us Table 18.185: TeSys GV7 Manual Starter and Protector Dimensions (cont’d) GV7AP03 or GV7AP04, GV7AP05 Direct Rotary Handle Front Fuse Center Enclosure Vewed from Top 0.36 9.25 = 0.35 9 3.94 100 4.72 120 2.32 59 = h e 1.61 41 4.92 125 4.72 120 2.72 69 = 2.0 51 = d Door cutouts require a minimum distance between the center of the manual motor protector and the door hinge point (h) of d ≥ 3.94 in (100 mm) + (h x 5) 3.94 100 GV7AP01, GV7AP02 Extended Rotary Handle 0.35 9 60 IEC CONTACTORS AND STARTERS = = I 2.95 75 18 0.36 9.25 0 60 L = = 2.95 75 L: 7.28 in. (185 mm) minimum, 23.62 in. (600 mm) maximum. The shaft of the extended rotary handle GV7AP01 or GV7AP02 must be cut to length: L – 4.96 in. (126 mm) 18-56 © 2012 Schneider Electric All Rights Reserved TeSys U Self-Protected Combination Starters www.schneider-electric.us TeSys U Self-Protected combination starters combine the requirements of motor overload and short-circuit protection into one compact package. These next-generation starters offer superior performance, efficiency, and a unique modular design to fit your needs with optional communication and predictive maintenance capabilities. They are UL listed, easy to install and maintain. In order to select a TeSys U Self-Protected combination starter, follow the 5-step process described below. 1. Choose a base configuration Table 18.186: Base Configurations Ratings Type 1/12/3R enclosure Max. HP Motor Voltage (V) Single phase 115 1.5 230 2 Non-reversing starter Three-phase 200 Max. Current Base (A) Configuration Number 3 230 3 460 7.5 Base Configuration Number $ Price Non-reversing starter Base Configuration Number $ Price $ Price Reversing starter Base Configuration Number $ Price 12 LE1U16 1917.00 LE2U16 2673.00 LE1U19 2112.00 LE2U19 2868.00 32 LE1U36 2115.00 LE2U36 2871.00 LE1U39 2310.00 LE2U39 3066.00 2 230 5 200 10 230 10 460 20 575 25 2. Choose Thermal Overload Relay (Plug-in Control Unit) The thermal overload relay is a control unit that plugs into the TeSys U starter. No tool is needed to install or remove the control unit. If you do not wish to select the thermal overload relay at this time, select Thermal Overload Relay Type codes N1 or N3 in function of the motor configuration (single phase or 3-phase) in Table 18.187. A thermal overload relay can be selected and ordered later on independently before installation. In order to select a thermal overload relay, you must follow the next 2 steps. First, select the thermal overload protection type code in Table 18.187. Secondly, select the full load amperage code in Table 18.188. Type 4/4Xenclosure Type 1/12/3R enclosure 2.1 Choose the thermal overload protection type. 2.2 Choose the Motor Full Load Amperage Table 18.187: Thermal Overload Protection Types Advanced Control Unit Multifunction Control Unit Table 18.188: Full Load Amperage Code No Control Unit (Ordered later on independently) Single Phase $ Price Thermal Overload Protection Type Code 180.00 Aa Ba 738.00 Ca Da 3-Phase Full Load Amperage Setting Range (A) Full Load Amperage Code 0.15–0.6 A 0.3–1.4 B 1.25–5.0 C 3–12 D 4.5–18 E 8–32 F — N1 N3 Protection Type Single phase, Class 10 3-phase, Class 10 3-phase, Class 20 3-phase, Selectable Class 5–30 b b b b Protection Functions Short circuit Over current Thermal overload Phase loss Phase imbalance Ground fault Underload, long start, jam b b b b c b b b b b b c b b b b b b c b b b b b b b Control Functions Automatic or local/remote reset c c c b Fault differentiation c c c b Thermal alarm c c c b Motor load display c c c b Fault history b Alarm threshold adjustment b Tripping test b b b b a Complete the Thermal Overload Relay Selection by adding the full load amperage code after the thermal overload protection type code. b Built-in Control Unit. c Available when combined with appropriate Function module. © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule 18-57 IEC CONTACTORS AND STARTERS 10 115 18 575 Type 4/4X enclosure Reversing starter TeSys U Self-Protected Combination Starters www.schneider-electric.us 3 Choose the Control Power Source 5 Choose Factory Modifications Table 18.189: Control Power Source Code Control Circuit Source Common Control System Type Single Phase ThreePhase Single Phase Separate Control 18 ThreePhase IEC CONTACTORS AND STARTERS Single Phase Factory Installed Control Power Transformer c Factory Installed Power Supply d a b c d ThreePhase Single Phase ThreePhase Motor Voltage Voltage 120 240 208 240 120 120 120 240 240 240 208 208 208 240 240 240 480 480 480 600 600 600 120 240 240 208 208 240 240 480 480 600 600 120 240 208 240 480 600 Voltage Type AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC AC Control Voltage Voltage 120 240 208 240 24 24 120 24 24 120 24 24 120 24 24 120 24 24 120 24 24 120 24 120 24 24 120 24 120 24 120 24 120 24 24 24 24 24 24 Voltage Type AC AC AC AC AC DC AC AC DC AC AC DC AC AC DC AC AC DC AC AC DC AC AC AC AC AC AC AC AC AC AC AC AC DC DC DC DC DC DC Control $ Power Source Code Price G7 U7 LE7 U7 B7a BDa G7a B7a BDa G7a B7a BDa G7a B7a BDa G7a B7a BDa G7a B7b BDb G7b V89 V80 V82 V90 V84 V82 V80 V83 V81 V91 V86 BD1 BD2 BD2 BD2 BD2 BD6 — — — — — — — — — — — — — — — — — — — — — — 698. 698. 698. 698. 698. 698. 698. 698. 698. 698. 698. 698. 827. 827. 827. 827. 1072. Form S must be added at the end of the catalog number. Form S6 must be added at the end of the catalog number. Current limiter is provided and factory installed. Two fuses in primary and one fuse in secondary provided as standard. Fuse holder with 2 fuses provided as standard. When choosing Factory modifications, the Form code must be added at the end of the catalog number. If several forms are selected, they must be arranged in alphabetical order. There are two types of Forms available: abbreviated forms and standard forms. 5.1 Abbreviated Forms Abbreviated forms are defined combinations of the most commonly ordered standard forms and are part of the profiled configurations with short lead time. For example, abbreviated form CP1 is a combination of standard forms C and P51. Abbreviated forms cannot be mixed with other standard forms, with the exceptions of forms S and S6. If your combination of forms is not available as an abbreviated form, use only standard forms and arrange them in alphabetical order. For example, LE1U16BDG7NCP1S is a valid catalog number with the abbreviated form CP1. If you want to add standard Form P68, the valid catalog number becomes LE1U16BDG7NCP51P68S. LE1U16BDG7NCP1P68S is invalid because abbreviated form CP1 cannot be used with standard form P68. Table 18.191: Abbreviated Forms Form $ Price Hand/Off/Auto Selector Switch + Red ON LED Standard Pilot Light Factory Modifications CP1 344.00 Hand/Off/Auto Selector Switch + Green ON LED Standard Pilot Light CP2 344.00 Hand/Off/Auto Selector Switch + Red ON LED Standard Pilot Light + Green OFF LED Standard Pilot Light C12 516.00 Hand/Off/Auto Selector Switch + Green ON LED Standard Pilot Light + Red OFF LED Standard Pilot Light C21 516.00 Start/Stop Push Buttons + Red ON LED Standard Pilot Light AP1 344.00 Start/Stop Push Buttons + Green ON LED Standard Pilot Light AP2 344.00 Start/Stop Push Buttons + Red ON LED Standard Pilot Light + Green OFF LED Standard Pilot Light A12 516.00 Start/Stop Push Buttons + Green ON LED Standard Pilot Light + Red OFF LED Standard Pilot Light A21 516.00 ON/OFF Selector Switch + Red ON LED Standard Pilot Light C61 344.00 ON/OFF Selector Switch + Green ON LED Standard Pilot Light C62 344.00 ON/OFF Selector Switch + Red ON LED Standard Pilot Light + Green OFF LED Standard Pilot Light C66 516.00 ON/OFF Selector Switch + Green ON LED Standard Pilot Light + Red OFF LED Standard Pilot Light C67 516.00 Red ON LED Standard Pilot Light + Green OFF LED Standard Pilot Light P12 344.00 Green ON LED Standard Pilot Light + Red OFF LED Standard Pilot Light P21 344.00 5.2 Standard Forms Table 18.192: Push Button Forms Factory Modifications 4 Choose Communication Type If you do not need communication capabilities, select communication code N. If a Communication protocol is selected, Control Voltage must be 24 Vdc (Control Power Source Codes BD, BD1, BD2 or BD6 only. Refer to Table 18.189). If additional I/O is needed with communication, select communication code N in Table 18.190 and choose between Forms W10, W11, W12, W13 and W14 in Table 18.204. Table 18.190: Communication Code Communication Protocol Form $ Price Start/Stop A 172.00 Forward/Reverse/Stop A1 172.00 ON/OFF A3 172.00 Miscellaneous A11 172.00 Stop A13 172.00 Start Push Button + Stop Mushroom Head A22 172.00 Emergency Stop Mushroom Head A31 172.00 Turn-To-Release Emergency Stop Mushroom Head A32 172.00 Table 18.193: Selector Switch Forms Communication Code $ Price Factory Modifications Form $ Price Modbus M 262.00 Hand/Off/Auto C 172.00 Modbus TCP/IP E 712.00 Start/Stop C1 172.00 CANopen C 262.00 ON/Auto C2 172.00 DeviceNet D 262.00 ON/OFF C6 172.00 Beckoff B 262.00 Hand/Auto C8 172.00 Profibus P 262.00 Forward/OFF/Reverse C14 172.00 Advantys STB A 262.00 Forward/Reverse C20 172.00 AS-interface J 226.00 Three position C34 172.00 AS-interface V2 K 226.00 Two position C35 172.00 No Communication N — Keyed Hand/Off/Auto C36 376.00 Keyed Start/Stop C37 376.00 Keyed ON/Auto C38 376.00 Keyed ON/OFF C39 376.00 Keyed Forward/Off/Reverse C43 376.00 Keyed Forward/Reverse C47 376.00 18-58 I11 Discount Schedule © 2012 Schneider Electric All Rights Reserved TeSys U Self-Protected Combination Starters www.schneider-electric.us Factory Modifications Table 18.201: Miscellaneous Forms Form $ Price Factory Modifications Form $ Price Red ON P51 172.00 Nameplate — 2”x1/2” screwed A241 Green OFF P52 172.00 Nameplate — 3”x1” screwed A242 43.00 43.00 White — Not Factory wired P54 172.00 Unwired Terminal Block G50a 57.00 Blue — Not Factory wired P56 172.00 Wired Terminal Block G56ab 116.00 Amber Overload Trip P68 172.00 Wire markers G105 675.00 Yellow SSC Trip P69 172.00 Padlock attachment G122 75.00 Red OFF P91 172.00 Transient suppressor U11 47.00 Green ON P92 172.00 Black IP65 Through the door Rotary Disconnect Handle G40 50.00 Green Forward/Reverse P95 344.00 Special factory orders SPL TAG Red Forward/Reverse P96 344.00 Custom control wiring Y217 Solid neutral Terminal Block Table 18.195: 22mm Push-To-Test LED Pilot Light Forms Form a b $ Price Red ON P42 223.00 Red OFF P43 223.00 Green ON P45 223.00 Green OFF P46 223.00 Blue — Not Factory wired P66 223.00 White — Not Factory wired P67 223.00 Green Forward/Reverse P79 446.00 Red Forward/Reverse P80 446.00 Amber Overload Trip P88 223.00 Yellow SSC Trip P89 223.00 Table 18.196: Separate Control Forms Factory Modifications Form $ Price Separate Control for starters with line voltage less or equal to 480 V S — Separate Control for starters with line voltage equalt to 600 V — Current Limiter is factory installed. S6 205.00 116.00 Add number of terminal block points required. Number must be in increments of 5. Wiring diagram must be provided by customer. Table 18.202: Increase Short Circuit Current Rating Forms Factory Modifications 130 kA @480 V — Current Limiter factory installed Form $ Price Y1261 205.00 Table 18.203: Soft Starter Forms NOTE: Motor Voltage must be equal to or less than 480 Vac and Control Voltage must be 24 Vdc (Control Power Source Codes BD, BD1, or BD2 only. Refer to Table 18.189). Factory Modifications Form $ Price Motor FLA < 6A H1 160.00 6 < Motor FLA < 9A H2 182.00 9 < Motor FLA < 12A H3 210.00 12 < Motor FLA < 22A H4 263.00 22 < Motor FLA < 32A H5 360.00 Table 18.204: Distributed 6 Input/6 Output Modicon STB with communication Forms Table 18.197: Additional Capacity Forms 18 Factory Modifications TAG N NOTE: Distributed I/O Modicon STB is factory wired. NOTE: Fuses are provided. Two fuses in primary and one fuse in secondary. Form $ Price Form $ Price 50VA additional capacity T10 215.00 DeviceNet Bus W10 1340.00 100VA additional capacity T11 372.00 Modbus TCP Bus W11 1417.00 Ethernet IP Bus W12 1503.00 CANOpen Bus W13 1298.00 Profibus Bus W14 1251.00 Form $ Price Factory Modifications Table 18.198: Auxiliary Contact Forms Factory Modifications Form $ Price 2 N.O. U8 41.00 1 N.O. and 1 N.C. U9 41.00 2 N.C. U10 41.00 Factory Modifications Table 18.205: Starter Status Indication Forms Factory Modifications 1 N.C. fault signaling contact and 1 N.O. contact indicating starter is in "ready" state U6 41.00 Fault Differentiation Module — Manual Reset 1 N.O. fault signaling contact and 1 N.O. contact indicating starter is in "ready" state U7 41.00 Fault Differentiation Module — Automatic or remote reset Table 18.199: Auxiliary Relay Forms U1 187.00 U2 187.00 Thermal Overload Alarm Module U3 187.00 Motor Load Indication Module U4 226.00 NOTE: Auxiliary Relays are not factory wired. Factory Modifications Form $ Price 4 poles screw clamp Control Relay — 4 N.O. R1740 485.00 4 poles screw clamp Control Relay — 3 N.O. and 1 N.C. R1731 485.00 4 poles screw clamp Control Relay — 2 N.O. and 2 N.C. R1722 485.00 Programmable Timer Relay K1070 449.00 Table 18.200: Enclosure Forms Factory Modifications Form $ Price Oversized enclosure — Only available for Type 1/12/3R G28 $425.00 Plain Blank Door — No covered pre-stamped holes G30 TAG © 2012 Schneider Electric All Rights Reserved I11 Discount Schedule IEC CONTACTORS AND STARTERS Table 18.194: 22mm Standard LED Pilot Light Forms 18-59 www.schneider-electric.us 18 IEC CONTACTORS AND STARTERS 18-60 © 2012 Schneider Electric All Rights Reserved
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:06:05 10:19:12-04:00 Modify Date : 2014:06:05 10:19:12-04:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:06:05 10:19:12-04:00 Format : application/pdf Document ID : uuid:a185f98f-9b2e-4ef5-a1a6-dbf75be95e8e Instance ID : uuid:38248146-362c-4b33-9719-050e18b46a9c Page Mode : UseNone Page Count : 60EXIF Metadata provided by EXIF.tools