40525406 D _Acrox UB534_ 519700 FCC

2016-04-11

: Pdf 519700-Fcc 519700-FCC CertsReports 519700 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 22

Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 1 Total Page: 18
Rev. 00
FCC 47 CFR PART 15 SUBPART B
TEST REPORT
For
USB 2.0 4 PORTS HUB
Model: UB534; UHC34; UHO34; UBB34; UBJ34
Trade Name: Acrox
Issued for
Acrox Technologies Co., Ltd.
8F, No. 437, Rui Guang Rd., Nei Hu Dist.,
Taipei 114, Taiwan, R.O.C.
Issued by
Compliance Certification Services Inc.
Hsintien Lab.
No. 165, Chunghsen Road, Hsintien City
Taipei Hsien, Taiwan
TEL: (02) 2217-0894
FAX: (02) 2217-1029
Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. Ltd. This document may be altered or revised by Compliance Certification Services
Inc. personnel only, and shall be noted in the revision section of the document.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 2 Rev. 00
TABLE OF CONTENTS
1 TEST RESULT CERTIFICATION ...........................................................................................3
2 EUT DESCRIPTION ...................................................................................................................4
3 TEST METHODOLOGY............................................................................................................5
3.1 EUT SYSTEM OPERATION..............................................................................................5
3.2 DECISION OF FINAL TEST MODE................................................................................5
4 SETUP OF EQUIPMENT UNDER TEST.................................................................................6
5 FACILITIES AND ACCREDITATIONS..................................................................................7
5.1 FACILITIES .........................................................................................................................7
5.2 LABORATORY ACCREDITATIONS AND LISTINGS ..................................................7
6 INSTRUMENT AND CALIBRATION......................................................................................8
6.1 MEASURING INSTRUMENT CALIBRATION ..............................................................8
6.2 TEST AND MEASUREMENT EQUIPMENT..................................................................8
7 LINE CONDUCTED & RADIATED EMISSION TEST.........................................................9
7.1 LIMIT ..................................................................................................................................9
7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION.........................................10
7.3 TEST PROCEDURE OF RADIATED EMISSION ........................................................12
7.4 TEST RESULTS .................................................................................................................14
APPENDIX I - PHOTOGRAPHS OF TEST SETUP...................................................................16
APPENDIX II - TEST RESULT OF FINAL DATAS ..................................................................18
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 3 Rev. 00
1 TEST RESULT CERTIFICATION
Applicant: Acrox Technologies Co., Ltd.
8F, No. 437, Rui Guang Rd., Nei Hu Dist.,
Taipei 114, Taiwan, R.O.C.
Manufacturer: Acrox Technologies Co., Ltd.
8F, No. 437, Rui Guang Rd., Nei Hu Dist.,
Taipei 114, Taiwan, R.O.C.
Equipment Under Test: USB 2.0 4 PORTS HUB
Trade Name: Acrox
Model: UB534; UHC34; UHO34; UBB34; UBJ34
Deviation: None
Detailed EUT Description: See Item 2 of this report
Date of Test: May 27, 2004
Applicable Standard Class / Limit Test Result
FCC Part 15 Subpart B Class B No non-compliance noted
Deviation from Applicable Standard
None
The above equipment was tested by Compliance Certification Services Inc. for compliance with
the requirements set forth in the FCC Rules and Regulations Part 15, Subpart B and the
measurement procedures were according to ANSI C63.4. This said equipment in the
configuration described in this report shows the maximum emission levels emanating from
equipment are within the compliance requirements.
Approved by: Reviewed by:
David Wang Vince Chiang
Manager of Hsintien Laboratory Section Manager of Hsintien Laboratory
Compliance Certification Services Inc. Compliance Certification Services Inc.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 4 Rev. 00
2 EUT DESCRIPTION
Product USB 2.0 4 PORTS HUB
Trade Name Acrox
Model UB534; UHC34; UHO34; UBB34; UBJ34
Housing Type Plastic
EUT Power Rating DC 5V from Host PC
AC Power During Test 120VAC / 60Hz to Host PC
Power Supply Manufacturer COMPAQ
Power Supply Model Number DPS-250RB A
AC Power Cord Type Unshielded, 1.8m (Detachable)
EUT I/O Cable Type Shielded, 0.01m (Non-Detachable)
OSC/Clock Frequency 30MHz
Model Differences:
Model Name Difference Tested (Checked)
Original UB534
UHC34
UHO34
UBB34
Additional
UBJ34
For marketing purpose only.
I/O PORT OF EUT
I/O PORT TYPE Q’TY TESTED WITH
1). USB Port 5 5
Note: Client consigns only one model sample (Model Number is UB534) to test.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 5 Rev. 00
3 TEST METHODOLOGY
3.1 EUT SYSTEM OPERATION
1. Windows XP boots system.
2. Run Emctest.exe To Activate All Peripherals And Display “H” Pattern On Monitor
Screen.
3. Run Winemc.exe and choose “H:/ & I:/ & J:/ & K:/” to activate EUT.
Note: Test program is self-repeating throughout the test.
3.2 DECISION OF FINAL TEST MODE
1. The following test mode were scanned during the preliminary test:
1.
Normal Mode
2. After the preliminary scan, the following test mode was found to produce the highest
emission level.
Conduction: Mode 1
Radiation: Mode 1
Then, the EUT configuration and cable configuration of the above highest emission mode
was recorded for all final test items.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 6 Rev. 00
4 SETUP OF EQUIPMENT UNDER TEST
Setup Diagram
See test photographs attached in Appendix I for the actual connections between EUT and
support equipment.
Support Equipment
No
Equipment
Model Serial No. FCC ID Trade Name
Data Cable Power Cord
1.
PS/2 Mouse
MS-S34 LZE11401040 DZL211029
BSMI ID:
4862A011 LOGITECH Shielded,
1.8m N/A
2.
PS/2
Keyboard 6311-TW4C/6 916590744C18F51367
S00000 BSMI ID:
4862A064 ACER Shielded,
1.8m N/A
3.
Modem 5JEG4033MKO L0063CG2D007190 5RJTAI-35500-
M5-E TOP-
SOLUTION Shielded,
0.7m Unshielded,
1.8m
4.
USB
2.0 HDD ME-911 N/A D33031 PORTABLE Shielded,
1.4m N/A
5.
USB
2.0 HDD ME-911 N/A D33031 PORTABLE Shielded,
1.4m N/A
6.
USB
2.0 HDD F12-U A0100215-3690019 BSMI ID:
4912A002 TeraSyS Shielded,
1.4m
Unshielded,
1.8m
with a core
7.
USB
2.0 HDD F12-U A0100215-3690019 BSMI ID:
4912A002 TeraSyS Shielded,
1.4m
Unshielded,
1.8m
with a core
8.
Host PC D51C 7308-KN8Z-0010 BSMI ID:
3912Q007 COMPAQ Shielded,
0.01m Unshielded,
1.8m
9.
Monitor 17IT GH17H4LT702622L R33475 SAMSUNG Shielded,
1.8m
with two cores
Unshielded,
1.8m
10.
Printer C61 N/A BSMI ID:
3902E006 EPSON Shielded,
1.8m Unshielded,
1.8m
Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during
emission test.
Grounding: Grounding was in accordance with the manufacturers requirements and conditions for the intended
use.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 7 Rev. 00
5 FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
CCS Taiwan Hsintien Lab at No. 165, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan.
The measurement facilities are constructed in conformance with the requirements of CISPR
16-1, ANSI C63.4 and other equivalent standards.
5.2 LABORATORY ACCREDITATIONS AND LISTINGS
The test facilities used to perform Electromagnetic compatibility tests are registered or
accredited by the organizations listed in the following table which includes the recognized
scope specifically.
Country Agency Scope of Accreditation Logo
USA A2LA
CFR 47, FCC Part 15/18 using ANSI 63.4; AS/NZS 3548;
VCCI V3; CNS 13438; CNS 13439; CNS 13783; CNS
14115; CISPR 11/EN 55011; CISPR 14-1/EN 55014-1;
CISPR 15/EN 55015; CISPR 22/EN 55022; EN
50081-1/EN 61000-6-3; EN 50082-1/EN 61000-6-4;
IEC/EN 61000-4-2, IEC/EN 61000-4-3, IEC/EN
61000-4-4, IEC/EN 61000-4-5, IEC/EN 61000-4-6,
IEC/EN 61000-4-8, IEC/EN 61000-4-11, IEC/EN
61000-3-2, IEC/EN 61000-3-3; CISPR 24/EN 55024;
CISPR 14-2/EN 55014-2; EN 50081-2/EN 61000-6-1; EN
50082-2/EN 61000-6-2.
824.01
USA FCC 3/10 meter Open Area Test Sites to perform FCC Part
15/18 measurements
250366
Japan VCCI 3/10 meter Open Area Test Sites and Line Conducted Test
Room to perform conducted/radiated measurements
R-1434/1630~4
C-1511/ 1882
Norway NEMKO
EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2/3/4, EN
50091-2, EN 50130-4, EN 55011, EN 55013, EN
55014-1/2, EN 55015, EN 55022, EN 55024, EN
61000-3-2/3, EN 61326-1, IEC 61000-4-2/3/4/5/6/8/11,
Cispr 16-1/2/3/4
ELA 103
Taiwan CNLA
47 CFR FCC Part 15 Subpart B, EN 61000-3-2, EN
61000-3-3, CNS 13439, CNS 13783-1, CNS 13438,
AS/NZS 3548, VCCI, CNS 13022-1/2/3, EN 55022, EN
55013, EN 55014-1, EN 61000-4-2/3/4/5/6/8/11, ENV
50204, ENV 50141, ENV 50142
Taiwan BSMI CNS 13438, CNS 13783-1, CNS 13439
SL2-IN-E-0005
SL2-A1-E-0005
SL2-R1-E-0005
SL2-R2-E-0005
Note: No part of this report may be used to claim or imply product endorsement by CNLA, A2LA or other
government agency.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 8 Rev. 00
6 INSTRUMENT AND CALIBRATION
6.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated once a year or in accordance with the manufacturer's recommendations, and is
traceable to recognized national standards.
6.2 TEST AND MEASUREMENT EQUIPMENT
The following list contains measurement equipment used for testing. The equipment conforms
to the requirement of CISPR 16-1, ANSI C63.2 and. other equivalent standards.
Calibration of all test and measurement, including any accessories that may effect such
calibration, is checked frequently to ensure the accuracy. Adjustments are made and
correction factors are applied in accordance with the instructions contained in the respective
manual.
Equipment Used for Emission Measurement
Open Area Test Site # J
EQUIPMENT MFR MODEL SERIAL
NUMBER CAL.
DUE
SITE NSA CCS J Site N/A 09/26/2004
MEASURE
RECEIVER SCHAFFNER SCR3501 330 06/16/2004
SPECTRUM
ANALYZER ADVANTEST R3132 120900003 11/04/2004
ANTENNA SCHAFFNER CBL 6112B 2800 09/27/2004
PRE-
AMPLIFIER SCHAFFNER CPA9231A 3629 10/10/2004
CABLE BELDEN 9913 N-TYPE #J1 10/10/2004
ATTENUATOR MCL UNAT-6 AT06-8 12/10/2004
THERMO-
HYGRO METER TFA N/A NO.3 11/23/2004
Above 1GHz Used
EMC ANALYZER
(100Hz-22GHz) HP 8566B 2937A06102 06/25/2004
ANTENNA
(1-18GHz) EMCO 3115 5761 02/02/2005
AMPLIFIER
(1-26.5GHz) HP 8449B 3008A01266 02/15/2005
CABLE
(1-18GHz) JYEBAO
HUBER+SUHNER
LL142
SUCOFLEX 104
SMA-RS1&2
SMA-RS3 02/15/2005
Note: The measurement uncertainty is less than +/- 3.36dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 9 Rev. 00
Conducted Emission Test Site # A
EQUIPMENT MFR MODEL SERIAL
NUMBER CAL.
DUE
TEST RECEIVER R&S ESHS20 840455/006 03/07/2005
LISN SOLAR 8012-50-R-24-BNC
8305114 02/10/2005
LISN (EUT) SCHWARZBECK NSLK 8127 8127382 01/05/2005
BNC CABLE MIYAZAKI 5D-FB BNC A1 01/30/2005
Note: The measurement uncertainty is less than +/- 2.83dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.
7 LINE CONDUCTED & RADIATED EMISSION TEST
7.1 LIMIT
Maximum permissible level of Line Conducted Emission
Class A (dBuV) Class B (dBuV)
FREQUENCY
(MHz) Quasi-peak Average Quasi-peak Average
0.15 - 0.5 79 66 66 - 56 56 - 46
0.50 - 5.0 73 60 56 46
5.0 - 30.0 73 60 60 50
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 10 meter
Class A (dBuV/m) Class B (dBuV/m)
FREQUENCY
(MHz) Quasi-peak Quasi-peak
30 – 230 40 30
230 - 1000 47 37
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 3 meter
Class A (dBuV/m) Class B (dBuV/m)
FREQUENCY
(MHz) Average Peak Average Peak
Above 1000 59.3 79.3 53.9 73.9
Note: The lower limit shall apply at the transition frequency.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 10 Rev. 00
7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION
Procedure of Preliminary Test
l The EUT was set up as per the test configuration to simulate typical usage per the user’s
manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is
used and is placed on the ground plane as per ANSI C63.4 (see Test Facility for the
dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is
placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the
EUT from the ground plane.
l Support equipment, if needed, was placed as per ANSI C63.4.
l All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
l The test system with EUT received AC power, 120V/60Hz, through a Line Impedance
Stabilization Network (LISN), which supplied power source and was grounded to the
ground plane.
l All support equipment received power from a second LISN.
l The EUT test program was started. Emissions were measured on each current carrying
line of the EUT using a EMI Test Receiver connected to the LISN powering the EUT. The
LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two
scans were taken: one with Line 1 connected to the Receiver and Line 2 connected to a 50
ohm load; the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to
the Receiver.
l The Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes.
l During the above scans, the emissions were maximized by cable manipulation.
l The test mode(s) described in Item 3.2 were scanned during the preliminary test.
l After the preliminary scan, we found the test mode described in Item 3.2 producing the
highest emission level.
l The EUT configuration and cable configuration of the above highest emission level were
recorded for reference of the final test.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 11 Rev. 00
Procedure of Final Test
l EUT and support equipment were set up on the test bench as per step 10 of the preliminary
test.
l A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
emissions. Emission frequency and amplitude were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit. If EUT emission level was less 2dB to the AV. limit in Q.P. mode, then
the emission signal was re-checked using an AV. detector.
l The test data of the worst-case condition(s) was recorded.
Data Sample:
Freq.
MHz
Read
Level
dBuV
Factor
dB Level
dBuV Limit
dBuV
Over
Limit
dB
Reading
Type
(P/Q/A)
Line
(L1/L2)
x.xx 42.95 0.55 43.50 56 -12.50 Q L1
Freq. = Emission frequency in MHz
Read Level = Uncorrected Analyzer/Receiver reading
Factor = Insertion loss of LISN + Cable Loss
Level = Read Level + Factor
Limit = Limit stated in standard
Over Limit = Reading in reference to limit
P = Peak Reading
Q = Quasi-peak Reading
A = Average Reading
L1 = Hot side
L2 = Neutral side
Calculation Formula
Over Limit (dB) = Level (dBuV) Limit (dBuV)
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 12 Rev. 00
7.3 TEST PROCEDURE OF RADIATED EMISSION
Procedure of Preliminary Test
l The equipment was set up as per the test configuration to simulate typical usage per the
user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of
0.8 meters is used which is placed on the ground plane. When the EUT is a floor-standing
equipment, it is placed on the ground plane which has a 3-12 mm non-conductive
covering to insulate the EUT from the ground plane.
l Support equipment, if needed, was placed as per ANSI C63.4.
l All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
l The EUT received AC power source, 120V/60Hz, from the outlet socket under the
turntable. All support equipment received power from another socket under the turntable.
l The antenna was placed at 10 meter away from the EUT as stated in ANSI C63.4. The
antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier
would be used.
l The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test
program was started. Emissions were scanned and measured rotating the EUT to 360
degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the
vertical and the horizontal polarization, to maximize the emission reading level.
l The test mode(s) described in Item 3.2 were scanned during the preliminary test:
l After the preliminary scan, we found the test mode described in Item 3.2 producing the
highest emission level.
l The EUT and cable configuration, antenna position, polarization and turntable position of
the above highest emission level were recorded for the final test.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 13 Rev. 00
Procedure of Final Test
l EUT and support equipment were set up on the turntable as per step 8 of the preliminary
test.
l The Analyzer / Receiver scanned from 30MHz to 1000MHz. Emissions were scanned and
measured rotating the EUT to 360 degrees, varying cable placement and positioning the
antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal
polarization, to maximize the emission reading level.
l Recorded at least the six highest emissions. Emission frequency, amplitude, antenna
position, polarization and turntable position were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit and only Q.P. reading is presented.
l The test data of the worst case condition(s) was recorded.
Data Sample:
Freq.
MHz Amptd
dBuV/m
Margin
dB Limit
dBuV/m
Reading
dBuV Factor
dB/m
Reading
Type
(P/Q/A)
Pol.
(H/V)
x.xx 26.2 -3.8 30 14 12.2 Q H
Freq. = Emission frequency in MHz
Reading = Uncorrected Analyzer/Receiver reading
Factor = Antenna Factor + Cable Loss + Attenuator (3/6/10dB) Amplifier Gain
Amptd = Uncorrected Analyzer/Receiver reading + Factor
Limit = Limit stated in standard
Margin = Reading in reference to limit
P = Peak Reading
Q = Quasi-peak Reading
A = Average Reading
H = Antenna Polarization: Horizontal
V = Antenna Polarization: Vertical
Calculation Formula
Margin (dB) = Amptd (dBuV/m) Limit (dBuV/m)
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 14 Rev. 00
7.4 TEST RESULTS
Line Conducted Emission
Model: UB534 Test Mode: Mode 1
Temperature: 25 °C Humidity: 72% RH
Test Results: Passed Tested by: Jimmy Chen
(The chart below shows the highest readings taken from the final data, see Appendix II for details.)
Six Highest Conducted Emission Readings
Frequency Range Investigated 150 kHz to 30 MHz
Freq
(MHz)
Read
Level
(dBuV)
Factor
(dB) Level
(dBuV)
Limit
Line
(dBuV)
Over
Limit
(dB)
Reading
Type
(P/Q/A)
Line
(L1/L2)
0.201 40.71 0.11 40.82 63.58 -22.76 P L1
0.230 41.57 0.11 41.68 62.44 -20.75 P L1
0.277 38.79 0.12 38.91 60.90 -21.99 P L2
18.920 35.33 0.83 36.16 60.00 -23.84 P L2
0.201 42.95 0.11 43.06 63.58 -20.52 P L2
0.230 39.41 0.11 39.52 62.44 -22.91 P L2
NOTE: The emission level was or more than 2dB below the Average limit, so no re-check anymore.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 15 Rev. 00
Radiated Emission
Model: UB534 Test Mode: Mode 1
Temperature: 29°C Humidity: 71% RH
Test Results: Pass Tested by: Marion Yu
(The chart below shows the highest readings taken from the final data, see Appendix II for details.)
Six Highest Radiated Emission Readings
Frequency Range Investigated 30 MHz to 1000 MHz at 10m
Freq
(MHz) Amptd
(dBuV/m)
Margin
(dB) Limit
(dBuV/m)
Reading
(dBuV) Factor
(dB/m)
Reading
Type
(P/Q/A)
Pol.
(H/V)
35.3200 27.43 -2.57 30.00 34.80 -7.37 P V
47.0600 24.52 -5.48 30.00 38.10 -13.58 P V
120.0150
24.39 -5.61 30.00 33.50 -9.11 P V
720.0400
31.05 -5.95 37.00 29.60 1.45 P V
120.0090
23.79 -6.21 30.00 32.90 -9.11 P H
480.0020
34.09 -2.91 37.00 36.00 -1.91 P H
NOTE: None.
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 16 Rev. 00
APPENDIX I - PHOTOGRAPHS OF TEST SETUP
LINE CONDUCTED EMISSION TEST
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 17 Rev. 00
RADIATED EMISSION TEST
Compliance Certification Services Inc.
Report No: 40525406-D Date of Issue: June 2, 2004
Page 18 Rev. 00
APPENDIX II - TEST RESULT OF FINAL DATAS
Conducted Emission Plot
Radiated Emission Data
No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1029
Data#: 3File#: 40525406C.EMI Date: 2004-05-27 Time: 15:45:56
Trace: 2 1 Ref Trace:
Condition: LINE
Report No. : 40525406
Test Engr. : JIMMY CHEN
Company : Acrox Technologies Co., Ltd.
EUT : UB534
Test Config : EUT / ALL PERIPHERALS
Type of Test: FCC CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read Limit Over
Freq Level Factor Level Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz dBuV dB dBuV dBuV dB
1 0.201 40.71 0.11 40.82 63.58 -22.76 Peak
2 0.230 41.57 0.11 41.68 62.44 -20.75 Peak
3 0.277 38.79 0.12 38.91 60.90 -21.99 Peak
4 0.322 34.75 0.12 34.87 59.66 -24.79 Peak
5 12.253 35.17 0.58 35.75 60.00 -24.25 Peak
6 18.920 35.33 0.83 36.16 60.00 -23.84 Peak
No. 199, Chung Sheng Road,
Hsin Tien City, Taipei,
Taiwan, R.O.C.
Tel:02-2217-0894 Fax:02-2217-1029
Data#: 6File#: 40525406C.EMI Date: 2004-05-27 Time: 15:50:45
Trace: 5 4 Ref Trace:
Condition: NEUTRAL
Report No. : 40525406
Test Engr. : JIMMY CHEN
Company : Acrox Technologies Co., Ltd.
EUT : UB534
Test Config : EUT / ALL PERIPHERALS
Type of Test: FCC CLASS B
Mode of Op. : NORMAL MODE
Page: 1
Read Limit Over
Freq Level Factor Level Line Limit Remark
_________ ______ ______ ______ ______ ______ ______
MHz dBuV dB dBuV dBuV dB
1 0.201 42.95 0.11 43.06 63.58 -20.52 Peak
2 0.230 39.41 0.11 39.52 62.44 -22.91 Peak
3 0.277 36.17 0.12 36.29 60.90 -24.61 Peak
4 0.322 32.17 0.12 32.29 59.66 -27.37 Peak
5 9.302 29.51 0.49 30.00 60.00 -30.00 Peak
6 18.039 32.53 0.80 33.33 60.00 -26.67 Peak

Navigation menu