529778 Catalog

120289-Attachment 120289-Attachment 120289-Attachment 783510 Batch7 unilog cesco-content

123322-Catalog 123322-Catalog 123322-Catalog 783510 Batch10 unilog cesco-content

18101-Catalog 18101-Catalog 18101-Catalog 783510 Batch10 unilog cesco-content

106573-Catalog 106573-Catalog 106573-Catalog 783510 Batch10 unilog cesco-content

699092-Catalog 699092-Catalog 699092-Catalog 783510 Batch10 unilog cesco-content

2014-10-17

: Pdf 529778-Catalog 529778-Catalog 783510 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 73

TM-1
Thermal Management
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Air Conditioner, Side-Mount Full-Size TM-22
Air Conditioner, Side-Mount Mid-Size TM-18
Air Conditioner, Side-Mount Subcompact TM-12
Air Conditioners Sizing and Selection TM-2
Air Conditioners, 3-Phase 460-Volt Side-Mount Full-Size TM-24
Air Conditioners, CR Compact, Mid-Size and Full-Size TM-28
Air Conditioners, T4 Line Indoor/Outdoor TM-5
Air Conditioners, Top-Mount Series TM-26
Airflow Monitor, Filter and Fan TM-56
Blower Fan Package; Fan and Blower Accessories TM-52
Cooling Fan and Exhaust Packages TM-44
Cooling Fans, Compact TM-42
Corrosion Inhibitors, Industrial TM-73
Fan Tray, 19 Inch Rack Mount TM-60
Fans, Blowers, Louvers, and Vents Sizing and Selection TM-40
Filter Fan and Exhaust Package, Outdoor TM-50
Filter Fan Packages TM-48
Heat Exchangers Sizing and Selection TM-34
Heat Exchangers, XR Series Compact and Mid-Size TM-36
Heaters Sizing and Selection TM-62
Heaters, Electric TM-66
Heaters, Semiconductor Control Panel TM-64
Hygrostat, Mechanical TM-70
Hygrotherm, Electronic TM-68
Louvers and Vents TM-54
Shroud Kit, Type 3R Fan TM-61
Speed Controls, DataCom Fan TM-58
Temperature Control Switches TM-72
Thermostat, Dual TM-71
Vortex Cooling Systems TM-32
INDEX
Heat builds up rapidly in enclosed environments,
compromising the performance and life span of
equipment. Like insurance for your electronics, effective
thermal management maximizes the efficiency and life
cycle of electrical components. As a leader in thermal
management, Hoffman offers a wide range of solutions
for heating and cooling enclosures, controlling moisture,
and filtering or moving air through an enclosure.
Whether your enclosure is indoors or out, sealed or
open to airflow, theres a reliable, proven Hoffman
thermal management solution available.
TM-2 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
Air Conditioners
Air Conditioners
Sizing and Selection
Before choosing a thermal management solution, you
need to carefully consider the specifics of your applica-
tion in addition to the following factors:
Fan packages and blowers may introduce ambient
contaminants like oil mist and dust into the enclo-
sure
Heat exchangers cannot cool below the ambient
temperature
Closed-loop air conditioners (this section) can cool
below ambient temperature and reduce humidity
without introducing contaminants
Simple ventilation devices such as louvers or grilles
and filters are appropriate if maintaining a cool,
constant temperature is not a critical factor
Once you have determined the proper form of cool-
ing equipment you need, selecting the required cooling
capacity is outlined in this section.
How to Read Air Conditioner Catalog Numbers
1. Identifies the type/family of air conditioner and the approximate
height (i.e., CR43 = CR family, about 43” high).
2. This is the air conditioner’s listed capacity in BTU/Hr. (i.e., 06 =
6000 BTU/Hr.)
3. 1 = 115 Volt or 2 = 230 Volt; 4 = 460 Volt
4. 6 = 50/60 Hz or 60 Hz (depending on unit, see Design Data); 5 =
50 Hz
5. Unique set of numbers for each air conditioner which identifies
the accessories on a model.
Selection and Sizing Software
Designed to assist you in determining the most
suitable choices of air conditioners, heat exchangers,
or fans for your application. Download a free copy
of our selection software by visiting our web site:
www.hoffmanonline.com.
Sizing Air Conditioners
Determine internal heat load in watts.
Determine the internal heat load produced by
equipment as total operating watts.
1 WATT = 3.413 BTU/Hr.
Determine desired temperature difference in degrees F.
1°C ΔT = 1.8°F ΔT
Determine the ΔT (°F), the temperature difference
between the maximum temperature outside the
enclosure (To) and the maximum desired
temperature inside the enclosure (Ti), which can be
calculated as:
To - Ti = ΔT for air conditioners.
Determine exposed surface area of the enclosure in
square feet.
AREA (ft2) 1 M2 = 10.76 ft2
Calculate the exposed surface area of the enclosure
in Square Feet:
AREA (ft2) = 2[(H” x W) + (H” x D”) + (W” x
D”)] ÷ 144
where “H, “W, and “D” are the dimensions of the
enclosure in inches.
Determine required air conditioner capacity.
(WATTS x 3.413) + [1.25 x AREA (ft2) x ΔT(°F)] = BTU/HR.
Use this formula to determine the required cooling capacity needed
to maintain the desired operating temperature for your enclosure.
This selection procedure applies to uninsulated, sealed, gasketed
enclosures in indoor locations.
All industrial air conditioners are rated at their maximum operating
point. Operating an air conditioner at temperatures below maximum
conditions will result in reduced cooling capacity. In other words,
operating 95°F ambient and 95°F enclosure temperature results in
a 10 percent to 20 percent reduction in the rated capacity. (Note:
full cooling capacity is probably not necessary at lower ambient
temperatures.)
Air conditioners are appropriate for applications in which:
The temperature inside the enclosure must be maintained at or
below ambient temperature
Humidity must be removed from the enclosure
Ambient air contaminants must be kept out of the enclosure
CR43 - 06 1 6 - 002
1 2 3 4 5
TM-3
Air Conditioners
Air Conditioners
Sizing and Selection
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
Thermal
Management
T4 Line Indoor/Outdoor Air Conditioners
Side-Mount Subcompact Air Conditioners
Side-Mount Compact Air Conditioners
Side-Mount Mid-Size Air Conditioners
Series
H W D
BTU/Hr. Watts
in. mm in. mm in. mm
T15 15.75 400 7.50 191 6.30 160 800 234
Series
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
13 13.25 337 14.25 362 7.80 198 1000 293
17 17.65 448 12.00 305 8.68 220 1800 527
Series
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
28 28.50 724 17.00 432 11.33 288 2000-4000 586-1172
33NSM 34.37 873 12.00 305 9.88 251 4000 1172
36N 38.72 984 15.00 381 11.33 288 6000 1758
T4 Line
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
T15 15.75 400 7.50 191 6.30 160 800 234
T20 20.00 508 10.00 254 9.90 251 2000 586
T29 29.00 737 17.00 432 11.30 287 4000 1172
T43 43.00 1093 15.75 400 10.99 279 6680-8600 1958-2520
T50 50.00 1270 19.00 483 11.05 281 13,100 3838
T53 52.85 1342 20.85 530 13.00 330 20,000 5860
Side-Mount Full-Size Air Conditioners
Series
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
52 52.63 1337 17.13 435 11.33 288 8000-12,000 2344-3516
TM-4 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
Air Conditioners
Air Conditioners
Sizing and Selection
Top-Mount Air Conditioners
Compact to Full-Size Air Conditioners
CR Series Air Conditioner Package Options
VC Vortex Cooler
Series
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
CR23 23.00 584 10.00 254 8.75 222 1600 469
CR29 29.50 749 15.75 400 8.63 219 2200-4000 645-1172
CR43 43.31 1100 15.75 400 10.25 260 6000-8500 1758-2490
Series
Cooling Capacity
Voltage Frequency (Hz)BTU/Hr. Watts
VC04— 400 117 115 50/60
VC09— 900 264 115 50/60
VC15— 1500 440 115 50/60
VC17— 1700 498 115 50/60
VC25— 2500 733 115 50/60
Series
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
HBII 10.25 260 17.00 432 21.08 535 2200-4000 645-1172
3-Phase 460-Volt Side-Mount Full-Size Air Conditioners
Series
H W D
BTU/Hr. Watts
in. mm in. mm in. mm
52 52.63 1337 17.13 435 11.33 288 3800-10,000 1113-2930
Series
H W D
BTU/Hr. Wattsin. mm in. mm in. mm
CR23 23.00 584 10.00 254 8.75 222 1600 469
CR29 29.50 749 15.75 400 8.63 219 2200-4000 645-1172
CR43 43.31 1100 15.75 400 10.25 260 6000-8500 1758-2490
TM-5
Air Conditioners
Air Conditioners
Sizing and Selection
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
Thermal
Management
T4 Line Indoor/Outdoor
Air Conditioners
Application
T4 Air Conditioners provide high-efficiency positive cooling for wall-
mount and stand-alone enclosures. Designed for indoor and outdoor
applications requiring up to UL Type 4 rating.
Features
Equipped with head pressure control for low ambient operation,
compressor heater, coated condenser coil, and thermostat
Surface and internal recess mounting capabilities
Thermostat located behind front grille
EMI/RFI noise suppressor is standard
Reusable and washable air filter is easily accessible without
removing front cover
Broad operating range of -40°F (-40°C) to 131°F (55°C)
800-13,100 units use a CFC-free or or low ozone-depleting
refrigerant (R134A); 20,000 BTU units use R22
Compact footprints minimize mounting surface requirements
Construction
Includes power cord with plug for standard grounded outlet
Built-in hanging brackets facilitate installation on door, side, or rear
of the enclosure
Condensate management system with base pan and drain
High performance, industrial grade and efciency fans provide
maximum heat transfer
Mounting template, hardware, gasket, and instruction manual
furnished
Finish
RAL 7035 smooth light gray polyester powder coating over
galvanized steel.
Industry Standards
Maintains UL/cUL Type 12, 3R, or 4 rating when properly installed on UL/cUL
Type 12 or 4 rated enclosure.
UL/cUL Listed, UL File Number SA6453
CE
Accessories
Replacement Filter
Closed Loop Cooling
These air conditioners are designed and tested to maintain a
UL50-rated separation of the external ambient airow from the
sealed cabinet interior. This protects the electronic controls and
equipment from shutdowns caused by heat, humidity, dust, and other
contaminants.
Bulletin
MCL
Bulletin
Air Conditioners
T4 Line Indoor/Outdoor
Air Conditioners MCL
TM-6 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
800 BTU 15.75 x 7.50 x 6.30 (400 x 191 x 160)Replacement Filter Catalog Number 10100091
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp.
Full Load
Amps
50 Hz Max. Amb. Temp 60 Hz Max. Amb. Temp Shipping Weight
Lbs./Kgs°F °C °F °C
T150116G100 110/115 50/60 1 800/800 3.8/3.6 125 52 131 55 27/12
T150126G100 220/230 50/60 1 800/900 1.4/1.5 125 52 131 55 27/12
Bulletin
Air Conditioners
MCL
T4 Line Indoor/Outdoor
Air Conditioners
TM-7
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
2000 BTU 20.00 x 10.00 x 9.90 (508 x 254 x 251)Replacement Filter Catalog Number 10100090
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp. Full Load Amps
60 Hz Max. Amb. Temp Shipping Weight
Lbs./Kgs°F °C
T200216G100 115 50/60 1 1800/2000 7 131 55 56/25
T200226G100 230 50/60 1 1800/2000 3.5 131 55 56/25
Bulletin
Air Conditioners
T4 Line Indoor/Outdoor
Air Conditioners MCL
TM-8 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
4000 BTU 29.00 x 17.00 x 11.30 (737 x 432 x 287)Replacement Filter Catalog Number 10100093
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp. Full Load Amps
60 Hz Max. Amb. Temp Shipping Weight
Lbs./Kgs°F °C
T290416G100 115 50/60 1 3600/4000 13.8/13.6 131 55 107/49
T290426G100 230 50/60 1 3600/4000 6.9/6.8 131 55 107/49
Bulletin
Air Conditioners
MCL
T4 Line Indoor/Outdoor
Air Conditioners
TM-9
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
6680-8600 BTU 43.00 x 15.75 x 10.99 (1093 x 400 x 279)Replacement Filter Catalog Number 10100096
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp. Full Load Amps
60 Hz Max. Amb. Temp Shipping Weight
Lbs./Kgs°F °C
T430616G100 115 50/60 1 6310/6680 9.2/8.6 131 55 125/57
T430626G100 230 50/60 1 6520/6770 4.4/3.8 131 55 125/57
T430816G100 115 50/60 1 7900/8600 10.4/11.2 131 55 125/57
T430826G100 230 50/60 1 7400/8200 5.2/5.4 131 55 125/57
Bulletin
Air Conditioners
T4 Line Indoor/Outdoor
Air Conditioners MCL
TM-10 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
13,100 BTU 50.00 x 19.00 x 11.05 (1270 x 483 x 281)Replacement Filter Catalog Number 10100083
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp. Full Load Amps
60 Hz Max. Amb. Temp Shipping Weight
Lbs./Kgs°F °C
T501226G100 230 50/60 1 11,600/13,100 9.0/9.5 131 55 164/75
Bulletin
Air Conditioners
MCL
T4 Line Indoor/Outdoor
Air Conditioners
TM-11
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
20,000 BTU 52.85 x 20.85 x 13.00 (1342 x 530 x 330)Replacement Filter Catalog Number 10100085
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp. Full Load Amps
60 Hz Max. Amb. Temp Shipping Weight
Lbs./Kgs°F °C
T531926100 230 50/60 1 18,000/20,000 17/19 131 55 197/90
Bulletin
Air Conditioners
Side-Mount Subcompact
Air Conditioner MCL
TM-12 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
This Side-Mount Subcompact Air Conditioner provides high-
efciency, positive cooling for wall-mount and narrow enclosures,
supporting industry trends toward smaller, densely-populated
enclosures with greater heat dissipation requirements. Can be side-
mounted on enclosures with 8 in. (203mm) or greater depth.
Construction
Models are equipped with a screwdriver-adjustable thermostat
located behind the front grille
EMI/RFI noise suppressor is standard
Subcompact models are ideal for cooling smaller enclosures. The
T15 series is only 7.50 in. (191mm) wide, making it ideal for wall-
mount enclosures or enclosures with narrow side walls.
Includes power cord with plug for standard grounded outlet
Built-in hanging brackets facilitate installation on door, side, or rear
of the enclosure
Reusable and washable air filter is easily accessible without
removing front cover
Condensate management system with base pan side drain
High-performance, industrial-grade ball-bearing fans provide
maximum heat transfer
All units use CFC-free, environmentally-safe R134A refrigerant
Mounting hardware, gaskets, mounting template, and instruction
manual furnished
Finish
RAL 7035 light gray polyester powder coating
Industry Standards
Maintains UL/cUL Type 12 or 3R rating when properly installed on a UL/cUL
Type 12 enclosure.
UL/cUL Listed, UL File Number SA6453
CE
Accessories
Replacement Filter
Closed Loop Cooling
These subcompact air conditioners are designed and tested to
maintain a UL50 rated separation of the external ambient airow
from the sealed cabinet interior. This protects the electronic
controls and equiment from shutdowns caused by heat, humidity,
dust, and other contaminants.
Standard Sizes Side-Mount Subcompact Air ConditionerReplacement Filter Catalog Number 10100091
Catalog Number Voltage Hz Phase
BTU/Hr. @ Max.
Ambient Temp. Full Load Amps
50 Hz Max Amb.
Temp. °F/°C
60 Hz Max Amb.
Temp. °F/°C
Shipping Weight
Lbs./Kgs
T150116G120 110/115 50/60 1 800 3.8/3.6 125/52 131/55 27/12.25
T150126G120 220/230 50/60 1 800 1.4/1.5 125/52 131/55 27/12.25
Bulletin
Air Conditioners
MCL
Side-Mount Subcompact
Air Conditioner
TM-13
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Bulletin
Air Conditioners
Side-Mount Compact
Air Conditioners MCL
TM-14 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Models are equipped with a thermostat control that offers
convenient digital display of enclosure temperature and high
temperature alarm (125°F/52°C). Flashing display indicates alarm
condition. EMI/RFI noise suppressor is standard. Compact models
are ideal for cooling smaller enclosures from 25 cu. ft. to 40 cu.
ft. The Series 17 model is only 12 inches wide, making it ideal for
enclosures with narrow side walls.
Features
Most components accessible by removing grille/lter
Hanging brackets facilitate installation on door, side, or front of
enclosure
For a typical application, unique condensate management system
evaporates moisture from enclosure
High performance, industrial-grade ball-bearing fans provide
maximum heat transfer
All units use a CFC-free or environmentally safe refrigerant that is
universally accepted
Mounting hardware, gaskets, mounting template and instruction
manual furnished
Finish
Body: RAL 7042 smooth gray polyester powder coating
Grille: RAL 7035 light gray
Industry Standards
Maintains U/cUL Type 12 rating when properly installed on a UL/cUL Type 12
enclosure.
UL/cUL Listed, UL File Number SA6453
CE
Closed Loop Cooling
Within the air conditioner, the recirculated clean air is kept separate
from the ambient airow system. This protects the electronic
controls and prevents shutdowns caused by heat, humidity, dust, and
other contaminants.
13 Series
17 Series
Ambient airflow
Clean airflow
NOTE: Hoffman side-mount models are directly interchangeable with comparable Slimboy and GENESIS™ models.
Bulletin
Air Conditioners
MCL
Side-Mount Compact
Air Conditioners
TM-15
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Side Mount 13 Series 13.25 x 14.25 x 7.8 0 (337 x 362 x 198) Replacement Filter No. 10100057
Catalog Number Voltage Hz Phase
BTU/Hr. @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M130116G1014 115 50/60 1 800/1000 4.0/4.0 125/52 48/22
M130126G1008 230 50/60 1 800/1000 2.2/2.1 125/52 48/22
Side Mount 17 Series 17.65 x 12.00 x 8.68 (448 x 305 x 220) Replacement Filter No. 10100057
Catalog Number Voltage Hz Phase
BTU/Hr. @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M170216G009 110/115 50/60 1 1500/1800 6.6/6.7 125/52 56/25
M170226G004 220/230 50/60 1 1500/1800 4.2/3.7 125/52 56/25
Side-Mount to Enclosure
Generally, the 13 Series air conditioners are most effective on
enclosures up to 25 cu. ft. unless the application only requires spot
cooling in a larger enclosure.
Side-Mount to Enclosure
Generally, the 17 Series air conditioners are most effective on
enclosures up to 40 cu. ft. unless the application only requires spot
cooling in a larger enclosure.
Bulletin
Air Conditioners
Side-Mount Compact
Air Conditioners MCL
TM-16 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Side-Mount 17 Series Air Conditioner Drawing
Side-Mount 13 Series Air Conditioner Drawing
Bulletin
Air Conditioners
MCL
Side-Mount Compact
Air Conditioners
TM-17
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Side-Mount 17 Series Air Conditioner Mounting Cutout Dimensions Drawing
Side-Mount 13 Series Mounting Cutout Dimensions Drawing
Bulletin
Air Conditioners
Side-Mount Mid-Size
Air Conditioners MCL
TM-18 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
28 Series air conditioners are equipped with a thermostat control
that offers convenient digital display of enclosure temperature and
high temperature alarm (125°F/52°C). Flashing display indicates
alarm condition. EMI/RFI noise suppressor is standard on all models.
33NSM Series and 36N Series offer a broad capacity range with the
advantage of mounting on narrow enclosures
Features
The 33NSM Series is only 12 inches wide and the 36N Series is 15
inches wide
Most components accessible by removing air filter
Hanging brackets facilitate installation on door, side, or front of
enclosure
For a typical application, unique condensate management system
evaporates moisture from enclosure
High performance, industrial-grade ball bearing fans in the 33
NSM, and high performance centrifugal blowers in the 28 and 36N,
provide maximum heat transfer in densely packed enclosures
All units use a CFC-free or environmentally-safe refrigerant that is
universally accepted
Mounting gaskets and instruction manual furnished
Finish
Body: RAL 7042 smooth gray polyester powder coating
Grille: RAL 7035 light gray
Industry Standards
Maintains UL/cUL Type 12 rating when properly installed on a UL/cUL Type 12
enclosure.
UL/cUL Listed, UL File Number SA6453
CE
Closed Loop Cooling
Within the air conditioner, the recirculated clean air is kept separate
from the ambient airow system. This protects the electronic
controls and prevents shutdowns caused by heat, humidity, dust, and
other contaminants.
Ambient airflow
Clean airflow
28 Series 33NSM Series
36N Series
Bulletin
Air Conditioners
MCL
Side-Mount Mid-Size
Air Conditioners
TM-19
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
28 Series 28.50 x 17.00 x 11.33 (724 x 432 x 288) Replacement Filter No. 10100056
Catalog Number Voltage Hz Phase
BTU/Hr @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M280216G013 115 50/60 1 2200/2200 9.8/9.0 125/52 98/45
M280226G004 230 50/60 1 2200/2200 5.0/4.5 125/52 98/45
M280416G007 115 50/60 1 3800/4000 14.6/14.0 125/52 116/53
M280426G032 230 50/60 1 3800/4000 7.4/6.9 125/52 116/53
Catalog Number Voltage Hz Phase
BTU/Hr @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M330416G010 115 50/60 1 3700/4000 13.0/13.2 125/52 105/48
M330426G009 230 50/60 1 3700/4000 7.2/7.3 125/52 105/48
Catalog Number Voltage Hz Phase
BTU/Hr @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M360616307 115 50/60 1 5000/6000 14.0/14.0 152/52 120/54
M360626306 230 50/60 1 5000/6000 7.0/7.0 152/52 120/54
33NSM Series 34.37 x 12.00 x 9.88 (873 x 305 x 251) Replacement Filter No. 10100057
36N Series 38.72 x 15.00 x 11.38 (984 x 381 x 288) Replacement Filter No. 10100056
Bulletin
Air Conditioners
Side-Mount Mid-Size
Air Conditioners MCL
TM-20 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
28 Series
33NSM Series
36N Series
Bulletin
Air Conditioners
MCL
Side-Mount Mid-Size
Air Conditioners
TM-21
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
28 Series
33NSM Series
36N Series
Side-Mount to Enclosure
Mounting Cutout Dimensions
Side-Mount to Enclosure
Mounting Cutout Dimensions
Side-Mount to Enclosure
Mounting Cutout Dimensions
Bulletin
Air Conditioners
Side-Mount Full-Size
Air Conditioners MCL
TM-22 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
52 Series air conditioners are equipped with a thermostat control
that offers convenient digital display of enclosure temperature and
high temperature alarm (125°F/52°C). Flashing display indicates alarm
condition. EMI/RFI noise suppressor is standard.
Features
Most components accessible by removing air filter
Mounting brackets facilitate installation on door, side, or front of
enclosure
For a typical application, unique condensate management system
evaporates moisture from enclosure
High performance centrifugal blowers are ideal for densely packed
enclosures
All units use a CFC-free or environmentally safe refrigerant that is
universally accepted
Mounting gaskets and instruction manual furnished
Finish
Body: RAL 7042 smooth gray polyester powder coating
Grille: RAL 7035 light gray
Industry Standards
8000 BTU/HR MODELS (115V and 230V)
Maintains UL/cUL Type 12 rating when properly installed on a UL/cUL Type 12
enclosure.
UL/cUL Listed, UL File Number SA6453
CE
12,000 BTU/HR MODELS (115V)
Maintains UL/cUL Type 12 rating when properly installed on a UL/cUL Type 12
enclosure.
UL/cUL Recognized, UL File Number SA6453
CE
12,000 BTU/HR MODELS (230V)
Maintains UL/cUL Type 12 rating when properly installed on a UL/cUL Type 12
enclosure.
UL/cUL Listed, UL File Number SA6453
CE
Bulletin
Air Conditioners
MCL
Side-Mount Full-Size
Air Conditioners
TM-23
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
52 Series 52.63 x 17.13 x 11.33 (1337 x 435 x 288) Replacement Filter No. 10100056
Catalog Number Voltage Hz Phase
BTU/Hr @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M520816032 115 50/60 1 6700/8000 14.5/14.5 125/52 160/73
M520826015 230 50/60 1 6700/8000 8.0/8.0 125/52 160/73
M521216017a110/115 50/60 1 10000/12000 24.4/23.0 125/52 175/79
M521226034 220/230 50/60 1 10000/12000 12.2/11.6 125/52 175/79
a UL Component Recognized and cUL Component Recognized.
52 Series
Ambient airflow
Clean airflow
Closed Loop Cooling
Within the air conditioner, the recirculated clean air is kept separate
from the ambient airow system. This protects the electronic
controls and prevents shutdowns caused by heat, humidity, dust, and
other contaminants.
Side-Mount to Enclosure
Mounting Cutout Dimensions
Bulletin
Air Conditioners
3-Phase 460-Volt Side-Mount Full-Size
Air Conditioners
MCL
TM-24 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
The 52 Series 460-Volt 3-phase air conditioner mounts to the
side of a large enclosure to cool electrical controls in industrial
environments. Efcient 460-Volt 3-phase compresssor and
motors eliminate the need for additional transformers in 460-Volt
applications.
Features
Thermostat control
Most components accessible by removing air filter
Digital display of enclosure temperature
Mounting brackets facilitate installation to enclosure
High-temperature alarm
Unique condensate management system evaporates moisture from
enclosure (for a typical application where the enclosure doors are
kept closed)
High-performance centrifugal blowers are ideal for circulating air
inside densely-packed enclosures
All units use a CFC-free, environmentally safe refrigerant that is
universally accepted (R134A)
Mounting gaskets and instruction manual furnished
EMI/RFI noise suppression is standard
Finish
Body: RAL 7042 smooth gray polyester powder coating
Grille: RAL 7035 light gray
Industry Standards
Maintains UL/cUL Type 12 or 3R rating when properly installed on a UL/cUL
Type 12 enclosure.
UL/cUL Listed, UL File Number SA6453
CE
Bulletin
Air Conditioners
MCL
TM-25
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
3-Phase 460-Volt Side-Mount Full-Size
Air Conditioners
52 Series 52.63 x 17.13 x 11.33 (1337 x 435 x 288) Replacement Filter No. 10100056
Catalog Number Voltage Hz Phase
BTU/Hr @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F/°C
Shipping Weight
Lbs./Kgs
M520446G002 460 50/60 3 3800/4100 1.8/1.6 125/52 162/74
M520646G002 460 50/60 3 5700/6000 2.0/1.8 125/52 162/74
M520846G002 460 50/60 3 6500/7500 3.5/3.2 125/52 162/74
M521046G002 460 50/60 3 8000/10000 3.7/3.4 125/52 165/75
Side-Mount to Enclosure
Mounting Cutout Dimensions
Ambient airflow
Clean airflow
Closed Loop Cooling
Within the air conditioner, the recirculated clean air
is kept separate from the ambient airflow system.
This protects the electronic controls and prevents
shutdowns caused by heat, humidity, dust, and other
contaminants.
Bulletin
Air Conditioners
Top-Mount Series Air Conditioners
MCL
TM-26 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Top-mount air conditioners are ideal for use where there is little or
no clearance around the enclosure. HB11 top-mount air conditioners
are equipped with a thermostat control that offers convenient
digital display of enclosure temperature and high temperature alarm
(125°F/52°C).
Features
Most components accessible by removing air filter
For a typical application, unique condensate management system
evaporates moisture from enclosure
High-performance CFM ball-bearing centrifugal blowers perform
well in densely packed enclosures
All units use a CFC-free or environmentally safe refrigerant that is
universally accepted
Mounting gaskets and instruction manual furnished
Finish
Body: RAL 7042 smooth gray polyester powder coating
Grille: RAL 7035 light gray
Industry Standards
Maintains UL/cUL Type 12 rating when properly installed on a UL/cUL Type 12
enclosure.
UL/cUL Recognized, UL File Number SA6453
CE
Top-Mount to Enclosure
For Type 12 enclosure, interfacing air-out
and air-in openings are required in the
enclosure top.
Ambient airflow
Clean airflow
NOTES: Hoffman top-mount units are directly interchangeable with comparable GENESIS™ and Slimboy models.
Closed Loop Cooling
Within the air conditioner, the recirculated clean air is kept separate
from the ambient airow system. This protects the electronic
controls and prevents shutdowns caused by heat, humidity, dust, and
other contaminants.
Bulletin
Air Conditioners
MCL
Top-Mount Series Air Conditioners
TM-27
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
HB11 Series 10.25 x 17.00 x 21.08 (260 x 432 x 536) Replacement Filter No. 10100056
Catalog Number Voltage Hz Phase
BTU/Hr (Watts) @
125°F/125°F Full Load Amps
Max. Ambient
Temp., °F (°C)
Shipping Weight
Lbs (Kgs)
MHB110216G306 115 50/60 1 2200/2200 9.7/9.0 125/52 104/47
MHB110226G306 230 50/60 1 2200/2200 5.5/4.6 125/52 104/47
MHB110416G307 115 50/60 1 3300/4000 14.7/13.6 125/52 118/54
MHB110426G306 230 50/60 1 3300/4000 8.0/7.5 125/52 118/54
Mounting Cutout Dimensions
Bulletin
Air Conditioners
CR Compact, Mid-Size, and Full-Size
Air Conditioners MCL
TM-28 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Features
Thermostat control and EMI/RFI noise suppressor included
Front cover hinges open for quick access to all components
Filter can be inverted to double operating time between cleanings
and or replacements (models CR23 and CR29 only)
Filterless operation possible in many applications
Mounting flanges facilitate installation on door, side, or front of
enclosure
For a typical application, unique condensate management system
evaporates moisture from enclosure
High-performance fans and blowers are ideal for densely-packed
enclosures
All units use a CFC-free or environmentally safe refrigerant that is
universally accepted
Mounting hardware, gaskets, mounting template and instruction
manual furnished
Finish
Available in brushed stainless steel or RAL 7035 light gray polyester
powder coating.
Industry Standards
UL/cUL Listed, UL File Number SA6453
CE
Air Conditioner Packages
The CR family of air conditioners is available in six different package
combinations.
Package 1: Basic
Maintains UL/cUL Type 12 or Type 3R rating when properly installed on a
UL/cUL Type 12 rated enclosure.
Standard air conditioner with painted mild steel exterior
Package 2: Level 2 Controller
Maintains UL/cUL Type 12 or Type 3R rating when properly installed on a
UL/cUL Type 12 rated enclosure.
Standard air conditioner with painted mild steel exterior
Includes microprocessor-based programmable temperature
management, digital display, and remote alarm capability
Package 3: Low Ambient Temperature
Maintains UL/cUL Type 12 or Type 3R rating when properly installed on a
UL/cUL Type 12 rated enclosure.
Standard air conditioner with painted mild steel exterior
For use where air conditioner must operate in ambient
temperatures below 50°F (10°C)
Lowest operating temp = 40°F (4.4°C)
Package 4: Low Ambient Temperature/SST/Corrosion
Maintains UL/cUL Type 12 or Type 3R rating when properly installed on a
UL/cUL Type 12 rated enclosure.
For use where air conditioner must operate in ambient
temperatures below 50°F (10°C)
Lowest operating temp = 40°F (4.4°C)
Type 304 stainless steel exterior for longer life in corrosive and
outdoor applications
For protection from corrosive environments, thermostat is tin-
plated and a special coating is applied to coils and copper lines
exposed to the ambient air
Package 5: Low Ambient Temperature/SST/Level 2
Controller
Maintains UL/cUL Type 12 or Type 3R rating when properly installed on a
UL/cUL Type 12 rated enclosure.
For use where air conditioner must operate in ambient
temperatures below 50°F (10°C)
Lowest operating temp = 40°F (4.4°C)
Type 304 stainless steel exterior for longer life in corrosive and
outdoor applications
Includes microprocessor-based, programmable temperature
management, digital display, and remote alarm capability
Package 6: Outdoor/SST/Corrosion/4X
Maintains UL/cUL Type 4X, 4, or 12 rating when properly installed on a UL/
cUL Type 4X, 4, or 12 rated enclosure.
For use where air conditioner must operate in ambient
temperatures below 50°F (10°C)
Lowest operating temp = 40°F (4.4°C)
Constructed of 304 stainless steel for increased protection in
corrosive and outdoor applications
For protection from corrosive environments, thermostat is tin-
plated and a special coating is applied to coils and copper lines
exposed to the ambient air
Protective shield, shown below, protects unit in outdoor and hose-
down applications and provides 4X rating. Shield protrudes about
2 inches (51mm) from the air conditioner.
Notes: Hoffman top-mounted units are directly interchangeable with comparable GENESIS™ and Slimboy models.
Shield maintains UL/cUL
Type 4X rating. (Package 6)
Ambient air enters from
the bottom
Bulletin
AIR CONDITIONERS
MCL
CR Compact, Mid-Size, and Full-Size
Air Conditioners
TM-29
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Standard Sizes CR Compact, Mid-Size, and Full-Size Air Conditioners
CR23 23.00 x 10.00 x 8.75 (584 x 254 x 222) Replacement Filter No. 23200400
Catalog
Number Voltage Hz Phase
BTU/Hr. @
131°F/13Fa
Amps @
131°F/13F
BTU/Hr. @
95°F/95°Fa
Amps @
95°F/95°F
Max Amb.
Temp °F/°C
Shipping
Weightb
Lbs./Kgs
CR230216GXXX 115 50/60 1 1400/1600 4.1/4.5 1500/1700 3.8/3.6 131/55 57/26
CR230226GXXX 230 50/60 1 1400/1600 2.2/2.2 1500/1700 2.1/1.8 131/55 57/26
CR29 29.50 x 15.75 x 8.63 (749 x 400 x 219) Replacement Filter No. 10100032
Catalog
Number Voltage Hz Phase
BTU/Hr. @
131°F/13Fa
Amps @
131°F/13F
BTU/Hr. @
95°F/95°Fa
Amps @
95°F/95°F
Max Amb.
Temp °F/°C
Shipping
Weightb
Lbs./Kgs
CR290216GXXX 115 50/60 1 2000/2200 7.4/7.4 1700/2000 7.0/6.0 131/55 98/44
CR290226GXXX 230 50/60 1 2500/2700 4.6/3.9 1900/2300 4.4/3.3 131/55 98/44
CR290416GXXX 115 50/60 1 3500/4000 13.5/13.5 2400/2800 10.7/9.6 131/55 118/54
CR290426GXXX 230 50/60 1 3500/4000 6.7/6.6 2400/2800 5.9/5.3 131/55 118/54
CR43 43.31 x 15.75 x 10.25 (1100 x 400 x 260) Replacement Filter No. 10100044
Catalog
Number Voltage Hz Phase
BTU/Hr. @
131°F/13F
Amps @
131°F/13F
BTU/Hr. @
95°F/95°F
Amps @
95°F/95°F
Max Amb.
Temp °F/°C
Shipping
Weightb
Lbs./Kgs
CR430616X XX 115 60 1 6000 13.7 5100 11.0 131/55 133 / 60
CR430626XXX 230 60 1 6000 6.9 5100 5.5 131/55 133/60
CR430816XXX 115 60 1 8500 16.0 7500 12.9 131/55 140/64
CR430826XXX 230 60 1 8500 8.2 7500 6.3 131/55 140/64
aBecause air conditioners provide less cooling at lower operating temperatures, two cooling capacity ranges are provided.
bFor Stainless Steel UL Type 4X models, add approximately 10 lbs. to shipping weight.
Catalog Number BTU/Voltage/Hz Package
CR230216G002 1600 BTU/Hr. 115V-50/60 Hz 1 - Basic
CR230216G016 1600 BTU/Hr. 115V-50/60 Hz 2 - Level 2 Controller
CR230216G013 1600 BTU/Hr. 115V-50/60 Hz 3 - Low Ambient Temperature
CR230216G007 1600 BTU/Hr. 115V-50/60 Hz 4 - Low Ambient/SST/Corrosion
CR230216G017 1600 BTU/Hr. 115V-50/60 Hz 5 - Low Ambient/SST/Level 2
CR230216G015 1600 BTU/Hr. 115V-50/60 Hz 6 - Outdoor/SST/Corrosion/4X
CR230226G002 1600 BTU/Hr. 230V-50/60 Hz 1 - Basic
CR230226G030 1600 BTU/Hr. 230V-50/60 Hz 3 - Low Ambient Temperature
CR230226G009 1600 BTU/Hr. 230V-50/60 Hz 4 - Low Ambient/SST/Corrosion
CR230226G016 1600 BTU/Hr. 230V-50/60 Hz 5 - Low Ambient/SST/Level 2
CR230226G014 1600 BTU/Hr. 230V-50/60 Hz 6 - Outdoor/SST/Corrosion/4X
CR290216G002 2200 BTU/Hr. 115V-50/60 Hz 1 - Basic
CR290216G030 2200 BTU/Hr. 115V-50/60 Hz 2 - Level 2 Controller
CR290216G035 2200 BTU/Hr. 115V-50/60 Hz 3 - Low Ambient Temperature
CR290216G013 2200 BTU/Hr. 115V-50/60 Hz 4 - Low Ambient/SST/Corrosion
CR290216G036 2200 BTU/Hr. 115V-50/60 Hz 6 - Outdoor/SST/Corrosion/4X
CR290226G002 2200 BTU/Hr. 230V-50/60 Hz 1 - Basic
CR290226G030 2200 BTU/Hr. 230V-50/60 Hz 2 - Level 2 Controller
CR290226G020 2200 BTU/Hr. 230V-50/60 Hz 3 - Low Ambient Temperature
CR290226G010 2200 BTU/Hr. 230V-50/60 Hz 4 - Low Ambient/SST/Corrosion
CR290226G031 2200 BTU/Hr. 230V-50/60 Hz 5 - Low Ambient/SST/Level 2
CR290226G037 2200 BTU/Hr. 230V-50/60 Hz 6 - Outdoor/SST/Corrosion/4X
CR290416G002 4000 BTU/Hr. 115V-50/60 Hz 1 - Basic
CR290416G047 4000 BTU/Hr. 115V-50/60 Hz 2 - Level 2 Controller
CR290416G045 4000 BTU/Hr. 115V-50/60 Hz 3 - Low Ambient Temperature
CR290416G030 4000 BTU/Hr. 115V-50/60 Hz 4 - Low Ambient/SST/Corrosion
CR290416G052 4000 BTU/Hr. 115V-50/60 Hz 5 - Low Ambient/SST/Level 2
CR290416G068 4000 BTU/Hr. 115V-50/60 Hz 6 - Outdoor/SST/Corrosion/4X
Catalog Number BTU/Voltage/Hz Package
CR290426G002 4000 BTU/Hr. 230V-50/60 Hz 1 - Basic
CR290426G027 4000 BTU/Hr. 230V-50/60 Hz 2 - Level 2 Controller
CR290426G022 4000 BTU/Hr. 230V-50/60 Hz 3 - Low Ambient Temperature
CR290426G017 4000 BTU/Hr. 230V-50/60 Hz 4 - Low Ambient/SST/Corrosion
CR290426G054 4000 BTU/Hr. 230V-50/60 Hz 6 - Outdoor/SST/Corrosion/4X
CR430616002 6000 BTU/Hr. 115V-60 Hz 1 - Basic
CR430616016 6000 BTU/Hr. 115V-60 Hz 2 - Level 2 Controller
CR430616013 6000 BTU/Hr. 115V-60 Hz 3 - Low Ambient Temperature
CR430616004 6000 BTU/Hr. 115V-60 Hz 4 - Low Ambient/SST/Corrosion
CR430616031 6000 BTU/Hr. 115V-60 Hz 6 - Outdoor/SST/Corrosion/4X
CR430626002 6000 BTU/Hr. 230V-60 Hz 1 - Basic
CR430626018 6000 BTU/Hr. 230V-60 Hz 2 - Level 2 Controller
CR430626014 6000 BTU/Hr. 230V-60 Hz 3 - Low Ambient Temperature
CR430626020 6000 BTU/Hr. 230V-60 Hz 5 - Low Ambient/SST/Level 2
CR430626034 6000 BTU/Hr. 230V-60 Hz 6 - Outdoor/SST/Corrosion/4X
CR430816002 8500 BTU/Hr. 115V-60 Hz 1 - Basic
CR430816021 8500 BTU/Hr. 115V-60 Hz 2 - Level 2 Controller
CR430816038 8500 BTU/Hr. 115V-60 Hz 3 - Low Ambient Temperature
CR430816010 8500 BTU/Hr. 115V-60 Hz 4 - Low Ambient/SST/Corrosion
CR430816023 8500 BTU/Hr. 115V-60 Hz 5 - Low Ambient/SST/Level 2
CR430816036 8500 BTU/Hr. 115V-60 Hz 6 - Outdoor/SST/Corrosion/4X
CR430826002 8500 BTU/Hr. 230V-60 Hz 1 - Basic
CR430826026 8500 BTU/Hr. 230V-60 Hz 2 - Level 2 Controller
CR430826007 8500 BTU/Hr. 230V-60 Hz 3 - Low Ambient Temperature
CR430826037 8500 BTU/Hr. 230V-60 Hz 4 - Low Ambient/SST/Corrosion
CR430826024 8500 BTU/Hr. 230V-60 Hz 5 - Low Ambient/SST/Level 2
CR430826038 8500 BTU/Hr. 230V-60 Hz 6 - Outdoor/SST/Corrosion/4X
NOTE: Some packages are not listed. Verify package before ordering.
Closed Loop Cooling
Within the air conditioner, the recirculated clean air is kept
separate from the ambient air ow system. This protects
the electronic controls and prevents shutdowns caused by
heat, humidity, dust, and other contaminants.
Ambient airfl ow
Clean airfl ow
Rev. A 06/07
Bulletin
Air Conditioners
CR Compact, Mid-Size, and Full-Size
Air Conditioners MCL
TM-30 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
CR23
CR29
CR43
Bulletin
Air Conditioners
MCL
CR Compact, Mid-Size, and Full-Size
Air Conditioners
TM-31
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
CR23 Mounting Cutout Dimensions
CR29 Mounting Cutout Dimensions
CR29 Side-Mount to Enclosure
CR43 Mounting Cutout Dimensions
CR23 Side-Mount to Enclosure
CR43 Side-Mount to Enclosure
CR23
CR29
CR43
Bulletin
Air Conditioners
Vortex Cooling Systems
MCL
TM-32 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
The compact size of VCool vortex cooling systems make them ideally
suited for small enclosures. Powered by compressed air (typically
100 psig, not to exceed 150 psig), VCool coolers generate chilled
air without refrigerants or moving parts. These coolers provide
exceptional reliability with minimal maintenance in even the most
harsh or dirty environments.
Construction
NEMA models are aluminum
All models include a 5-micron airline filter, 115V solenoid,
thermostat, and a ducting kit to distribute cold air throughout the
enclosure
Thermostatically controlled to save energy by operating only when
necessary
Cooling capacities to 2500 Btu/Hr (733 W).
Finish
Brushed satin aluminum or stainless steel.
Industry Standards
NEMA Type 4 Models:
Maintains UL/cUL Type 4 when properly installed on a UL/cUL Type 4
enclosure.
UL508, File Number E187045: Type 4
NEMA Type 4X Models:
Maintains UL/cUL Type 4X when properly installed on a UL/cUL Type 4X
enclosure.
UL508, File Number E187045: Type 4X
NEMA Type 12 Models:
Maintains UL/cUL Type 12 when properly installed on a UL/cUL Type 12
enclosure.
UL508, File Number E187045: Type 12
Accessories (for the enclosure)
Can be installed on all enclosure product families.
Separate VCool accessories include in-line oil filter and 230V
solenoid.
How the VCool Vortex Cooling System Works
The VCool Vortex cooling system uses the principle of vortex
cooling. A vortex occurs when a fluid (air) rotates around an axis,
like a tornado.
A vortex tube creates a vortex from compressed air and then
separates it into hot and cold airstreams.
On entering the VCool tube, the compressed air flow first passes
through a vortex generation chamber, which starts the air stream
rotating. The air stream exiting the chamber rotates at speeds up
to 1,000,000 rpm as it is forced along the inner walls of the tube
towards the control valve. At the control valve a small portion of
the air exits through a needle valve as hot exhaust. The remaining
air is forced back through the center of the incoming air stream at
a slower speed, where the slower-moving return air gives up heat
energy to the faster-moving incoming air. The cooled return air
then flows through the center of the vortex generation chamber
and exits through the cold air exhaust port.
NOTE: Manufactured for Hoffman by ITW Vortec.
Vortex Tube Air Flow Schematic
Bulletin
Air Conditioners
MCL
Vortex Cooling Systems
TM-33
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Standard Sizes VC Series NEMA Type 12
Catalog
Number
Cooling
Capacity
BTU/Hr.
Cooling
Capacity
W
Compressed Air
Consumption
SCFM
Compressed Air
Consumption
/m
Noise Level
db Voltage
Frequency
Hz Material
Weight
lb.
Weight
kg
VC0416012 400 117 8 227 69 115 50/60 Aluminum 5 2.27
VC0916012 900 264 15 425 80 115 50/60 Aluminum 6 2.72
VC1516012 1500 440 25 708 83 115 50/60 Aluminum 6 2.72
VC2516012 2500 733 35 991 90 115 50/60 Aluminum 6 2.72
Standard Sizes VC Series NEMA Type 4, 4X
Catalog
Number
Cooling
Capacity
BTU/Hr.
Cooling
Capacity
W
Compressed Air
Consumption
SCFM
Compressed Air
Consumption
/m
Noise Level
db Voltage
Frequency
Hz Material
Weight
lb.
Weight
kg
VC0916004 900 264 15 425 83 115 50/60 Aluminum 6 2.72
VC1716004 1700 498 25 708 86 115 50/60 Aluminum 6 2.72
VC2516004 2500 733 35 991 90 115 50/60 Aluminum 6 2.72
VC091604X 900 264 15 425 83 115 50/60 Stainless Steel 6 2.72
VC171604X 1700 498 25 708 86 115 50/60 Stainless Steel 6 2.72
VC251604X 2500 733 35 991 90 115 50/60 Stainless Steel 6 2.72
Accessory Catalog
Number Description
Use with
VCool Model Capacity
VC0F17 Oil filter Up to 1700 BTU/Hr.
VC0F25 Oil filter 2500 BTU/Hr.
Typical Installation
NEMA Type 12 - 400 BTU/Hr.
NEMA Type 12 -
900, 1500, 2500 BTU/Hr.
NEMA Type 4X
900, 1700, 2500 BTU/Hr.
TM-34 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
HeAt exCHAngers
Heat Exchangers
Sizing and Selection
Sizing Heat Exchangers
Determine internal heat load in watts.
1 WATT = 3.413 BTU/Hr.
Determine the internal heat load produced by
equipment as total operating watts.
Determine desired temperature difference in degrees F.
1°K ΔT = 1.F ΔT °K ΔT = °C ΔT
Determine the ΔT (°F), the temperature difference
between the maximum temperature outside
the enclosure (To) and the maximum desired
temperature inside the enclosure (Ti), which can be
calculated as:
Ti - To = ΔT for heat exchangers.
Determine exposed surface area of the
enclosure in square feet.
AREA (ft2) 1 M2 = 10.76 ft2
Calculate the exposed surface area of the enclosure
in Square Feet:
AREA (ft2) = 2[(H” x W) + (H” x D”) + (W” x D)] ÷ 144
where “H, “W, and “D” are the dimensions of the enclosure.
Determine required heat exchanger performance rating.
WATTS ÷ ΔT(°F) - [0.22 x AREA (ft2)] = WATTS/°F.
Use this formula to determine the required cooling capacity needed
to maintain the desired operating temperature for your enclosure.
This selection procedure applies to uninsulated, sealed, gasketed
enclosures in indoor locations.
It is recommended that the average “Air In” rating be used when
sizing an application. However, it may be possible to use a lower-
rated heat exchanger by locating the most heat sensitive components
in line with the “Air Out” opening of the heat exchanger. The actual
performance rating of any heat exchanger may vary slightly because
of the airflow impedance of the specific electronics configurations.
Heat exchangers are appropriate for applications in which:
the electronic controls can operate at a temperature above the
ambient temperature
humidity is not a factor
ambient air contaminants must be kept out of the enclosure
Selection and Sizing Software
Designed to assist you in determining the most
suitable choices of air conditioners, heat exchangers,
or fans for your application. Download a free copy of
our selection software by visiting our web site:
www.hoffmanonline.com.
Before choosing a thermal management solution, you
need to carefully consider the specifics of your applica-
tion in addition to the following factors:
Fan packages and blowers may introduce ambient
contaminants like oil mist and dust into the enclo-
sure
Heat exchangers (this section) cannot cool below
the ambient temperature
Closed-loop air conditioners can cool below am-
bient temperature and reduce humidity without
introducing contaminants
Simple ventilation devices such as louvers or grilles
and filters are appropriate if maintaining a cool,
constant temperature is not a critical factor
Once you have determined the proper form of cool-
ing equipment you need, selecting the required cooling
capacity is outlined in this section.
When Should You Use a Heat Exchanger?
A heat exchanger is recommended when:
ambient air contaminants must be kept out of the enclosure
the integrity of the enclosure must be maintained
temperature slightly above ambient inside the cabinet is acceptable
humidity is not a factor
How to Read Heat Exchanger Catalog Numbers
1. Heat Exchanger Series
XR = XR Modified Heat Pipe Core heat exchanger
2. This is the approximate height of the heat exchanger
(i.e., 29 = 29” high).
3. Capacity in W/°F
4. 1 = 115V, 2 = 230V
5. 6 = 50/60 Hz
6. UL Type.
1 3 4 5
XR 29 18 1 6 012
2 6
TM-35
HeAt exCHAngers
Heat Exchangers
Sizing and Selection
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
Thermal
Management
Compact and Mid-Size Heat Exchangers
Series
A B C Enclosure Air In Enclosure Air Out
in. mm in. mm in. mm W/ ˚F W/˚K W/˚F W/˚K
XR2004_ 20.00 508 7.50 191 3.00 76 4 7 9 16
XR2908_ 29.50 749 10.00 254 3.09 79 9 16 30 54
XR2918_ 29.66 753 10.24 260 5.92 150 18 32 34 61
XR4724_ 47.16 1198 10.24 260 5.92 150 24 43 44 79
XR4735_ 47.16 1198 15.24 387 5.92 150 35 63 77 139
XR6055_ 59.66 1515 15.24 387 5.92 150 55 99 138 248
XR6084_ 59.66 1515 15.24 387 9.92 252 84 151 210 378
XR Compact and Mid-Size
Bulletin
HeAt exCHAngers
XR Series Compact and Mid-Size
Heat Exchangers MCLHE
TM-36 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
These high-efficiency heat exchangers have a closed-loop design that
separates dirty ambient air from the clean air inside the enclosure
to maintain the integrity of the enclosure and extend equipment life.
Available in 7 sizes, these streamlined units are designed for limited
space applications, especially on narrow or shallow enclosures.
Construction
Unique cores provide high efciency and high performance heat
transfer
- Modified heat pipe core on XR20 and XR2908
- Counterflow aluminum core on XR2918, XR47, and XR60
Top-quality ball-bearing fans result in extended reliable service
Streamlined aesthetics with no visible mounting rails or fasteners.
The slim design allows for mounting to narrow or shallow
enclosures.
Front cover hinges open for easy access to all components
Filterless design. The core slides out for easy cleaning
Mounts vertically or horizontally on front, side or top of enclosure
Mounts inside or outside the enclosure
Enclosure air return plenum is provided
DC voltage available if required. Please contact Hoffman. Service
cord provided includes appropriate plug:
- NEMA 5-15P for 115V units
- NEMA 6-15P for 230V units
Mounting gaskets and instruction manual furnished
Finish
Coated with RAL 7035 polyester powder paint inside and out
Industry Standards
Maintains UL/cUL Type 12 or Type 3R rating when properly installed on the
appropriate UL/cUL Type 12 enclosure.
Note: Maintains Type 3R rating when mounted externally and in a vertical
position.
Note: XR200416012 and XR200426012 do not carry Type 3R rating.
UL/cUL Listed, UL File Number SA7402
CE
When Should You Use a Heat Exchanger?
A heat exchanger is recommended when:
Ambient air contaminants must be kept out of the enclosure
The integrity of the enclosure must be maintained
Temperature slightly above ambient inside the cabinet is acceptable
Humidity is not a factor
Closed Loop Air Circulation
Within the heat exchanger, the recirculated clean air is kept separate
from the ambient airow system. This protects the electronic
controls and prevents shutdowns caused by heat, humidity, dust, and
other contaminants.
NOTE: Hoffman XR units are directly interchangeable with ProAir models.
XR Series
Ambient airflow
Clean airflow
Bulletin
HeAt exCHAngers
MCLHE
XR Series Compact and Mid-Size
Heat Exchangers
TM-37
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Standard Sizes XR Series Compact and Mid-Size Heat Exchangers
Catalog Number
A x B x C
in. (mm) Voltage Hz Phase
Full Load
Amps
Max Amb.
Temp.
° F/°C
Enclosure Air Ina
W/°F (W/°K)
Enclosure
Air Outa
W/°F (W/°K)
Shipping
Weight
lb./kg
XR200416012b20.00 x 7.50 x 3.00 (508 x 191 x 76) 115 50/60 1 0.6 140/60 4 (7) 9 (16) 16/7
XR200426012b20.00 x 7.50 x 3.00 (508 x 191 x 76) 230 50/60 1 0.3 140/60 4 (7) 9 (16) 16/7
XR290816012 29.50 x 10.00 x 3.09 (749 x 254 x 79) 115 50/60 1 0.6 140/60 8 (14) 30 (54) 27/12
XR290826012 29.50 x 10.00 x 3.09 (749 x 254 x 79) 230 50/60 1 0.3 140/60 8 (14) 30 (54) 27/12
XR291816012 29.66 x 10.24 x 5.92 (753 x 260 x 150) 115 50/60 1 1.0 140/60 18 (32) 34 (61) 34/16
XR291826012 29.66 x 10.24 x 5.92 (753 x 260 x 150) 230 50/60 1 0.6 140/60 18 (32) 34 (61) 34/16
XR472416012 47.16 x 10.24 x 5.92 (1198 x 260 x 150) 115 50/60 1 1.5 140/60 24 (43) 44 (79) 51/24
XR472426012 47.16 x 10.24 x 5.92 (1198 x 260 x 150) 230 50/60 1 0.8 140/60 24 (43) 44 (79) 51/24
XR473516012 47.16 x 15.24 x 5.92 (1198 x 387 x 150) 115 50/60 1 1.5 140/60 35 (63) 77 (139) 63/29
XR473526012 47.16 x 15.24 x 5.92 (1198 x 387 x 150) 230 50/60 1 0.8 140/60 35 (63) 77 (139) 63/29
XR605516012 59.66 x 15.24 x 5.92 (1515 x 387 x 150) 115 50/60 1 6.7 140/60 55 (99) 138 (248) 91/42
XR605526012 59.66 x 15.24 x 5.92 (1515 x 387 x 150) 230 50/60 1 3.4 140/60 55 (99) 138 (248) 91/42
XR608416012 59.66 x 15.24 x 9.92 (1515 x 387 x 252) 115 50/60 1 6.7 140/60 84 (151) 210 (378) 115/53
XR608426012 59.66 x 15.24 x 9.92 (1515 x 387 x 252) 230 50/60 1 3.4 140/60 84 (151) 210 (378) 115/53
aThe “enclosure air in” efficiency rating is based on air entering the heat exchanger from the enclosure. The “enclosure air out” efficiency rating is based on air exiting the heat exchanger
into the enclosure. All XR exchanger units are rated at 100°F/3C ambient temperatures with 1500W internal heat load. Heat exchanger efficiency will decrease as ambient temperature
and/or internal heat load decreases.
bXR200416012 and XR200426012 do not carry Type 3R rating.
Application Tip
Locate heat-sensitive components in line with the “Air Out” opening
of the heat exchanger.
Bulletin
HeAt exCHAngers
XR Series Compact and Mid-Size
Heat Exchangers MCLHE
TM-38 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
XR20, XR2908 Heat Exchangers Drawing
XR2918 and XR4724 Heat Exchangers
XR4735 and XR60 Heat Exchangers
Bulletin
HeAt exCHAngers
MCLHE
XR Series Compact and Mid-Size
Heat Exchangers
TM-39
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Enclosure Cutouts
TM-40 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Fans, Blowers, Louvers, and Vents
Sizing and Selection
Selection and Sizing Software
Designed to assist you in determining the most
suitable choices of air conditioners, heat exchangers,
or fans for your application. Download a free copy
of our selection software by visiting our web site:
www.hoffmanonline.com.
How to Read Filter Fan Package Catalog Numbers
Filter Fans
1. Filter fan
2. Approximate size of fan frame (i.e., 05 = 5”)
3. 1 = 115 Volt, or 2 = 230 Volt
4. 6 = 50/60 Hz
5. Standard Model
Exhaust Grille Kit
1. Exhaust grille kit
2. Approximate size of fan frame (i.e., 05 = 5”)
3. Standard model
SF - 05 1 6 - 001
1 2 3 4 5
Determine the required fan/blower size
(volume airflow):
Step 1 Select the product family which best fits your
application:
Compact Cooling Fans (economical fan with no filter)
Cooling Fan Packages (economical fan package with low-density
filter)
Type 12 Cooling Fan Package
Filter Fan Packages (high-tech fan package with high-density filter,
for IP54 rating)
Blower Package (centrifugal blower package with filter for densely-
packed enclosures)
Step 2 Determine the internal heat load in WATTS.
1 WATT = 3.413 BTU/Hr.
Step 3 Determine desired temperature
difference in degrees F.
Determine the ΔT (F), the temperature difference
between the maximum temperature outside
the enclosure (To) and the maximum desired
temperature inside the enclosure (Ti).
To - Ti = ΔT for heat exchangers and fans
NOTE: 1°C ΔT = 1.8°F ΔT
Step 4 Plot your application using the selection graph to the
right.
Find WATTS (internal heat load) on the vertical scale
Draw a horizontal line across to the intersection point with the
diagonal line representing your ΔT
Extend a vertical line down to the horizontal scale to determine
your CFM requirement
Continue the vertical line to identify applicable fan or blower
A sample line is shown in red for a 400 watt heat load and a ΔT
of 2F, which indicates a 70 CFM airow requirement.
Step 5
Make sure the line intersects the bar which includes the exhaust
grille kit(s) from the product family chosen in Step 1. Remember,
actual air flow going through your enclosure may be less depending
on how densely packed your enclosure is.
Note: Fan output (CFM) is reduced by 10-15% when operated at 50Hz.
Cooling Fan and Blower Selection
CFMaFilter Fan Packages
29 SF05
57 SF09
126 SF10
250 SF13
CFMaCooling Fan Packages
55 TFP41, TFP42
140 TFP61, TFP62
215 TFP101, TFP102
CFMaBlower Package
260 ADB275
aCFM with one exhaust grille @ 60Hz
EG - 0500 - 001
1 2 3
TM-41
FAns, Blowers,
louvers, And vents
Fans, Blowers, Louvers, and Vents
Sizing and Selection
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2006 Hoffman Enclosures Inc.
Thermal
Management
Compact Cooling Fans
Cooling Fan Packages
Filter Fan Packages
Blower Package
Louvers and Vents
Catalog No.
Diameter
in. (mm)
Square
in. (mm)
Depth
in. (mm)
CFM@60Hz
(M3/Hr.)
A4AXFN 4.69 (119) 1.52 (39) 100 (170)
A6AXFN 6.72 (171) 2.00 (51) 240 (408)
A10AXFN10.00 (254) 3.50 (89) 560 (951)
Catalog No.
Diameter
in. (mm)
Square
in. (mm)
Depth
in. (mm)
CFM@60Hz
(M3/Hr.)
TFP41 6.29 (160) 7.37 (187) 2.65 (67) 55 (95)
TFP61 7.80 (198) 8.87 (225) 3.75 (95) 140 (238)
TFP10111.81 (300 12.99 (330) 5.25 (133) 215 (370)
NOTE: CFMs with single exhause grille installed
Catalog No.
Diameter
in. (mm)
Square
in. (mm)
Depth
in. (mm)
CFM@60Hz
(M3/Hr.)
SF05 5.83 (148) 5.83 (148) 2.76 (70) 29 (49)
SF09 8.03 (204) 8.03 (204) 3.78 (96) 57 (97)
SF10 9.84 (250) 9.84 (250) 5.20 (132) 126 (214)
SR13 12.72 (323) 12.72 (323) 6.09 (155) 250 (425)
NOTE: CFMs with single exhause grille installed
Catalog No.
Diameter
in. (mm)
Square
in. (mm)
Depth
in. (mm)
CFM@60Hz
(M3/Hr.)
ADB275 5.75 (146) 19.00 (483) 7.25 (184) 230/275 (135/162)
Three styles of louvers and vents provide passive cooling.
Bulletin
Fans, Blowers,
louvers, and vents
Compact Cooling Fans
D85
TM-42 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Designed for use in enclosures where space is limited and reliable
cooling is required. Powered by 115 volt or 230 volt AC, 60/50 Hz
single-phase motors and available in three sizes with nominal airflows
of 100, 240, and 560 cubic feet per minute (CFM). These fans are
ideal for applications where compact and quiet service is desired.
Features
Rigid housing eliminates breakage and grounding problems
Maximum operating temperature is 158º F (70º C)
4-inch fan is thermally protected and uses permanently lubricated
ball bearings
6- and 10-inch fans have ball-bearing construction and split-
capacitor motors
Split-capacitor motors are thermally protected to avoid premature
failure
Engineered for 50,000 hours of continuous operation without
lubrication or service
Construction
Dynamically balanced impellers molded from polycarbonate
material
One finger guard is furnished (an additional finger guard is
recommended for maximum safety)
All mounting hardware is provided
NOTE: Fan bracket and additional finger guards must be
purchased separately,
240 and 560 CFM fans have ball bearing construction and split
capacitor motors
Fans have leadwires with ends stripped 1/2 inch (12 millimeters) or
6 ft (1.83m) cord with polarized plug for power connections.
Consult your local Hoffman sales office for information on modifications to this
product.
Finish
Fan housing is black.
Industry Standards
UL Component Recognized
CSA certified
Accessories
Fan Brackets
Finger Guard
Temperature Control Switch
Installation
Can be installed on any surface of an enclosure. With the addition of
accessory fan brackets, Compact Cooling Fans can also be installed
in any position inside the enclosure for spot cooling or air circulation.
Technical/Performance Data for Compact Cooling Fans
Catalog
Number Nominal Size
Power
Connection
Voltage
(VAC)
Amps @
50/60 Hz
Watts @
50/60 Hz
CFM @
50/60 Hz Fan Size
Fan
Depth
Max. Motor
Operating RPM @
50/60 Hz
Noise SIL
(db)
A4AXFNGQ 4 in. Quiet Fan Power cord 115 .09/.08 6/5 46/49 4.69 in. square 1.52 1350/1450 27/28
A4AXFNPG 4 in. Power cord 115 .26/.21 17/15 85/100 4.69 in. square 1.52 2415/2900 37/41
A4AXFN 4 in. Leadwires 115 .26/.21 17/15 85/100 4.69 in. square 1.52 2415/2900 37/41
A4AXFN2 4 in. Leadwires 230 .14/.11 16/14 85/100 4.69 in. square 1.52 2415/2900 37/41
A6AXFNGQ 6 in. Quiet Fan Power cord 115 .16/.19 16/18 85/102 6.77 in. diameter 1.50 1400/1650 35/38
A6AXFNPG 6 in. Power cord 115 .45/36 36/32 200/240 6.77 in. diameter 1.50 2670/3200 50/56
A6AXFN 6 in. Leadwires 115 .45/.36 36/32 200/240 6.77 in. diameter 1.50 2670/3200 50/56
A6AXFN2 6 in. Leadwires 230 .23/.18 39/35 200/240 6.77 in. diameter 1.50 2670/3200 50/56
A10AXFNPG 10 in. Power cord 115 1.0/.88 36/36 480/560 10.00 in. diameter 3.50 1350/1650 45.8/49
A10AXFN 10 in. Leadwires 115 1.0/.88 36/36 480/560 10.00 in. diameter 3.50 1350/1650 45.8/49
A10AXFN2 10 in. Leadwires 230 .47/.43 36/36 480/560 10.00 in. diameter 3.50 1350/1650 45.8/49
Rev. A 7/07
Bulletin
FAns, Blowers,
louvers, And vents
D85
Compact Cooling Fans
TM-43
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Cutout Dimensions Compact Cooling Fans
Catalog
Number
Nominal
Size
Power
Connection Voltage
A
(in.)
A
(mm)
D
(in.)
D
(mm)
E
(in.)
E
(mm)
J
(in.)
J
(mm)
K
(in.)
K
(mm)
L
(in.)
L
(mm)
M
(in.)
M
(mm)
A4AXFNPG 4 inch Power cord 115 4.62 117 4.12 105 2.06 52 4.12 105 2.06 52
A4AXFNGQ 4 inch Power cord/Quiet 115 4.62 117 4.12 105 2.06 52 4.12 105 2.06 52
A4AXFN 4 inch Leadwires 115 4.62 117 4.12 105 2.06 52 4.12 105 2.06 52
A4AXFN2 4 inch Leadwires 230 4.62 117 4.12 105 2.06 52 4.12 105 2.06 52
A6AXFNPG 6 inch Power cord 115 5.88 149 3.19 81 6.38 162
A6AXFNGQ 6 inch Power cord/Quiet 115 5.88 149 3.19 81 6.38 162
A6AXFN 6 inch Leadwires 115 5.88 149 3.19 81 6.38 162
A6AXFN2 6 inch Leadwires 230 5.88 149 3.19 81 6.38 162
A10AXFNPG 10 inch Power cord 115 9.00 229 6.88 175 3.44 87 6.88 175 3.4 87
A10AXFN 10 inch Leadwires 115 9.00 229 6.88 175 3.44 87 6.88 175 3.44 87
A10AXFN2 10 inch Leadwires 230 9.00 229 6.88 175 3.44 87 6.88 175 3.44 87
Used to
power
compact
cooling fans
when positive
ground of
the cabinet
case is
required. Available with connectors for one or two fans. Five-foot
(1.52 meter) cord with grounded three-prong plug. Fits A4AXFNPG,
A6AXFNPG, A10AXFNPG, A4AXFNGQ, and AGAXFNGQ.
Catalog Number Description
ACORD1 One connector
ACORD2 Two connectors
Fan Cords
Designed to provide easy
mounting of Hoffman cooling
fans on enclosure panels.
Brackets can be used for general
air circulation or to direct air at
problem areas. All sizes are .100
inch aluminum. Package quantity
of 1 bracket. Fans must be
ordered separately.
Catalog
Number
Used with
Fan Catalog Number
A x B x C
in. (mm) D (in.) D (mm) E (in.) E (mm) F (in.) F (mm) G (in.) G (mm) H (in.) H (mm) J (in.) J (mm)
ABRKT4 A4AXFNPG, A4AXFNGQ,
A4AXFN, or A4AXFN2
6.00 x 5.00 x 1.50
(152 x 127 x 38)
3.50 89 3.00 76 1.00 25 0.38 10 0.62 16
ABRKT6 A6AXFNPG, A6AXFNGQ,
A6AXFN, or A6AXFN2
10.00 x 6.88 x 2.00
(254 x 175 x 51)
6.50 51 5.00 127 0.94 24 0.38 10 1.00 25
ABRKT10 A10AXFNPG, A10AXFNGQ,
A10AXFN, or A10AXFN2
13.5 x 10.12 x 3.5
(343 x 257 x 89)
8.50 216 4.00 102 4.00 102 1.06 27 0.62 16 2.00 51
Fan Brackets
One finger guard is included with
each Compact Cooling Fan and
Cooling Fan Package. Additional
finger guards can be mounted
on either side of the fan for
maximum safety. All guards are
chrome-plated and meet UL 507
.25-inch plug gauge test.
Catalog Number
Use on
Compact Cooling Fan Catalog Numbers
AGARD4 A4AXFNPG, A4XFNGQ, A4AXFN, A4AXFN2
AGARD6 A6AXFNPG, A6AXFNGQ, A6AXFN, A6AXFN2
AGARD10 A10AXFNPG, A10AXFNQR, A10AXFN, A10AXFN2
Finger Guards
Bulletin
FAns, Blowers,
louvers, And vents
Cooling Fan and Exhaust Packages
D85
TM-44 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Designed for use in enclosures where space is limited and reliable
filtered airflow is required. The Cooling Fan Package is the air inlet
of a cooling system. It requires at least one Exhaust Package of the
same size and type rating to provide the outlet. Where positive air
flow through the enclosure is not required, Exhaust Packages can be
used on both the inlet and outlet.
NOTE: fan and exhaust packages must be ordered separately.
The Cooling Fan Package is available for both Type 1 and Type 12
enclosures. Type 1 is recommended in UL Type 1 environments
where the ambient air is cool and clean. Type 12 is recommended
in UL Type 12 environments where the ambient air is cool and
may contain small amounts of dust, foreign bodies, and splashing
water. For both Type 1 and Type 12 systems a monthly maintenance
schedule is recommended to ensure optimal cooling performance.
The cooling fan and exhaust packages come with RAL 7035
composite or brushed stainless steel grilles; replacement black ABS
composite and brushed stainless steel grilles are available separately.
The optional EMC Upgrade Kit prepares the fan and exhaust
packages for use where EMC protection is required.
Installation
Fan and exhaust packages can be installed on any surface of an
enclosure. They are most effective when the fan assembly is located
on a lower panel of the enclosure and the exhaust grille is positioned
near the top of the opposite side. This installation assists heat
transfer by causing slightly more turbulence and also prolongs the
working life of the fan since it is located in the path of the cooler air
entering the enclosure.
The height and width of the cooling fans and exhaust grilles can be
rotated 90° for mounting on narrow enclosures. Allow adequate
clearance for servicing the fan when equipment is installed inside the
enclosure and for replacing filters on both the fan and the exhaust.
Cutout dimensions for both the fan and the exhaust are shown in the
order table. Order the fan and exhaust packages separately.
Features
Cooling Fan Package includes fan, air filter, composite air plenum,
finger guard, and grille
Exhaust Package includes air filter, filter retainer with integral
finger guard, and grille
EMC Upgrade Kit includes a grille standoff collar and a special
EMC shielding grille. It can be used with either fan or exhaust
packages that have composite grilles. Cannot be used with stainless
steel grilles.
Optional grilles, available in both brushed stainless steel and black
ABS plastic, can be used with either the fan or exhaust package
Washable foam (Type 1) or disposable (Type 12) filter in both fan
and exhaust packages provide good arrestment of airborne dirt
with minimal pressure drop. Optional washable aluminum air filter
is available for Type 1 applications.
Durable composite air plenum and grille takes up minimal
enclosure space. Plenum permits even airow through the filter
for maximum filtering efciency. An integral and removable finger
guard on either side of the plenum adds safety and convenience.
Air filters can be accessed for cleaning from outside the enclosure
Rigid fan housing eliminates breakage and grounding problems
Engineered for 50,000 hours of continuous operation without
lubrication or service
Construction
Dynamically-balanced fan impellers molded from polycarbonate
material
4-in. fan is thermally protected and uses permanently-lubricated
ball bearings
6- and 10-in. fans have ball bearing construction and split-capacitor
motors that are thermally protected to avoid premature failure
Fans have leadwires for power connection with ends stripped 1/2-
in. (12 mm)
All mounting hardware and installation instructions are furnished
Filters
Standard Type 1 air filters are washable foam.
Note: Type 12 air filters are not washable.
Finish
Fan housing, composite plenum, and grille are RAL 7035 light gray.
Stainless steel grilles have brushed finish. ABS composite grille is
black.
Industry Standards
UL 508A Component Recognized, File Number E61997
CSA certified (fan only)
CE
Accessories
Temperature Control Switch
Aluminum Type 1 and Hi-Density Type 12 Filters
EMC Upgrade Kit
Grille Options:
Stainless Steel
Black ABS Plastic
Bulletin
Fans, Blowers,
louvers, and vents
D85
Cooling Fan and Exhaust Packages
TM-45
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Standard Sizes and Cutout Dimensions Cooling Fan and Exhaust Packages
Catalog
Number
A x B x C
in. (mm) Material and Type
Use with
Exhaust Grille
Nominal
Fan Size
D
(in.)
D
(mm)
F
(in.)
F
(mm)
H
(in.)
H
(mm)
T
(in.)
T
(mm)
W
(in.)
W
(mm)
TFP41 6.29 x 7.37 x 2.65
(160 x 187 x 67)
Composite Grille
UL 508 Type 1
TEP4 4 inch 0.45 11 5.66 144 0.77 20 4.12 105 6.39 162
TFP41SS 6.29 x 7.37 x 2.65
(160 x 187 x 67)
Stainless Steel Grille
UL 508 Type 1
TEP4SS 4 inch 0.45 11 5.66 144 0.77 20 4.12 105 6.39 162
TFP41UL12 6.29 x 7.37 x 2.65
(160 x 187 x 67)
Composite Grille
UL 508 Type 12
TEP4UL12 4 inch 0.45 11 5.66 144 0.77 20 4.12 105 6.39 162
TFP42 6.29 x 7.37 x 2.65
(160 x 187 x 67)
Composite Grille
UL 508 Type 1
TEP4 4 inch 0.45 11 5.66 144 0.77 20 4.12 105 6.39 162
TFP42SS 6.29 x 7.37 x 2.65
(160 x 187 x 67)
Stainless Steel Grille
UL 508 Type 1
TEP4SS 4 inch 0.45 11 5.66 144 0.77 20 4.12 105 6.39 162
TFP42UL12 6.29 x 7.37 x 2.65
(160 x 187 x 67)
Composite Grille
UL 508 Type 12
TEP4UL12 4 inch 0.45 11 5.66 144 0.77 20 4.12 105 6.39 162
TFP61 7.80 x 8.87 x 3.75
(198 x 225 x 95)
Composite Grille
UL 508 Type 1
TEP6 6 inch 0.49 12 7.16 182 1.33 34 4.50 114 7.89 200
TFP61SS 7.80 x 8.87 x 3.75
(198 x 225 x 95)
Stainless Steel Grille
UL 508 Type 1
TEP6SS 6 inch 0.49 12 7.16 182 1.33 34 4.50 114 7.89 200
TFP61UL12 7.80 x 8.87 x 3.75
(198 x 225 x 95)
Composite Grille
UL 508 Type 12
TEP6UL12 6 inch 0.49 12 7.16 182 1.33 34 4.50 114 7.89 200
TFP62 7.80 x 8.87 x 3.75
(198 x 225 x 95)
Composite Grille
UL 508 Type 1
TEP6 6 inch 0.49 12 7.16 182 1.33 34 4.50 114 7.89 200
TFP62SS 7.80 x 8.87 x 3.75
(198 x 225 x 95)
Stainless Steel Grille
UL 508 Type 1
TEP6SS 6 inch 0.49 12 7.16 182 1.33 34 4.50 114 7.89 200
TFP62UL12 7.80 x 8.87 x 3.75
(198 x 225 x 95)
Composite Grille
UL 508 Type 12
TEP6UL12 6 inch 0.49 12 7.16 182 1.33 34 4.50 114 7.89 200
TFP101 11.81 x 12.99 x 5.25
(300 x 330 x 133)
Composite Grille
UL 508 Type 1
TEP10 10 inch 0.55 14 11.16 283 2.14 54 6.88 175 11.89 302
TFP101SS 11.81 x 12.99 x 5.25
(300 x 330 x 133)
Stainless Steel Grille
UL 508 Type 1
TEP10SS 10 inch 0.55 14 11.16 283 2.14 54 6.88 175 11.89 302
TFP101UL12 11.81 x 12.99 x 5.25
(300 x 330 x 133)
Composite Grille
UL 508 Type 12
TEP10UL12 10 inch 0.55 14 11.16 283 2.14 54 6.88 175 11.89 302
TFP102 11.81 x 12.99 x 5.25
(300 x 330 x 133)
Composite Grille
UL 508 Type 1
TEP10 10 inch 0.55 14 11.16 283 2.14 54 6.88 175 11.89 302
TFP102SS 11.81 x 12.99 x 5.25
(300 x 330 x 133)
Stainless Steel Grille
UL 508 Type 1
TEP10SS 10 inch 0.55 14 11.16 283 2.14 54 6.88 175 11.89 302
TFP102UL12 11.81 x 12.99 x 5.25
(300 x 330 x 133)
Composite Grille
UL 508 Type 12
TEP10UL12 10 inch 0.55 14 11.16 283 2.14 54 6.88 175 11.89 302
An intake grille and filter are included with each Cooling Fan Package. Order at least one Exhaust Package separately for each installation
Bulletin
FAns, Blowers,
louvers, And vents
Cooling Fan and Exhaust Packages
D85
TM-46 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Catalog
Number
CFMa
50/60 Hz
Watts
50/60 Hz Voltage Hz
Amps
50/60 Hz
Max. Operating
Temp. °F
Max. Operating
Temp. °C
Max. Operating
Noise SIL db
Weight
(lb.)
Weight
(kg.)
TFP41 46/55 17/15 115 50/60 .26/.21 158 70 37/41 4.2 1.90
TFP41SS 46/55 17/15 115 50/60 .26/.21 158 70 37/41 4.2 1.90
TFP41UL12 21/25 17/15 115 50/60 .26/.21 158 70 37/41 4.2 1.90
TFP42 46/55 16/14 230 50/60 .14/.11 158 70 37/41 4.3 1.95
TFP42SS 46/55 16/14 230 50/60 .14/.11 158 70 37/41 4.3 1.95
TFP42UL12 21/25 16/14 230 50/60 .14/.11 158 70 37/41 4.3 1.95
TFP61 117/140 36/32 115 50/60 .45/.36 158 70 50/56 5.3 2.40
TFP61SS 117/140 36/32 115 50/60 .45/.36 158 70 50/56 5.3 2.40
TFP61UL12 50/60 36/32 115 50/60 .45/.36 158 70 50/56 5.3 2.40
TFP62 117/140 39/35 230 50/60 .23/.18 158 70 50/56 5.4 2.45
TFP62SS 117/140 39/35 230 50/60 .23/.18 158 70 50/56 5.4 2.45
TFP62UL12 50/60 39/35 230 50/60 .23/.18 158 70 50/56 5.4 2.45
TFP101 180/215 64/80 115 50/60 .58/.70 167 75 54/61 12.0 5.45
TFP101SS 180/215 64/80 115 50/60 .58/.70 167 75 54/61 12.0 5.45
TFP101UL12 63/75 64/80 115 50/60 .58/.70 167 75 54/61 12.0 5.45
TFP102 180/215 64/80 230 50/60 .29/.35 167 75 54/61 11.4 5.17
TFP102SS 180/215 64/80 230 50/60 .29/.35 167 75 54/61 11.4 5.17
TFP102UL12 63/75 64/80 230 50/60 .29/.35 167 75 54/61 11.4 5.17
aCFM with single exhaust grille installed.
Technical Performance Data for Cooling Fan Packages
4 in. Cooling Fan Package
4 in. Exhaust Package
Two 4 in. Exhaust Packages
4 in. Type 12 Cooling Fan Package
6 in. Cooling Fan Package
6 in. Exhaust Package
Two 6 in. Exhaust Packages
6 in. Type 12 Cooling Fan Package
10 in. Cooling Fan Package
10 in. Exhaust Package
Two 10 in. Exhaust Packages
10 in. Type 12 Cooling Fan Package
Performance Curve for a 4”
Cooling Fan Package @ 60 Hz
Performance Curve for a 6”
Cooling Fan Package @ 60 Hz
Performance Curve for a 10”
Cooling Fan Package @ 60 Hz
Bulletin
FAns, Blowers,
louvers, And vents
D85
Cooling Fan and Exhaust Packages
TM-47
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Optional grilles offer the
choice of stainless steel or
black ABS plastic grilles replace
the standard RAL 7035 gray
composite or stainless steel
grilles on both fan and exhaust
packages. Standard replacement
filters are washable foam (Type
1) or disposable (Type 12). To
maintain UL Type 12 rating on
the enclosure, UL Type 12 filters
must be used on both the inlet and outlet. Washable aluminum
filters are also available. Aluminum filters are compatible with Type 1
systems only.
Catalog
Number Description
Fits Fan and
Exhaust
Nominal Size
Fits Fan and
Exhaust Grille Size
in. (mm)
TG4SS Brushed stainless steel grille 4 inch 6.29 x 7.31 x .81
(160 x 186 x 21)
TG4B Black ABS plastic grille 4 inch 6.29 x 7.37 x .81
(160 x 187 x 21)
AFLTR4 Type 1 filter replacement
(5/package)
4 inch
AFLTR4AL Aluminum filter replacement
(5/package)
4 inch
TFLT4UL12 Type 12 filter replacement
(5/package)
4 inch
TG6SS Brushed stainless steel grille 6 inch 7.80 x 8.81 x .75
(198 x 224 x 19)
TG6B Black ABS plastic grille 6 inch 7.80 x 8.87 x .49
(198 x 225 x 12)
AFLTR6 Foam filter replacement
(5/package)
6 inch
AFLTR6AL Aluminum filter replacement
(5/package)
6 inch
TFLT6UL12 UL 12 filter replacement
(5/package)
6 inch
TG10SS Brushed stainless steel grille 10 inch 11.81 x 12.92 x .75
(300 x 328 x 19)
TG10B Black ABS plastic grille 10 inch 11.81 x 12.99 x .75
(300 x 330 x 19)
AFLTR10 Foam filter replacement
(5/package)
10 inch
AFLTR10AL Aluminum filter replacement
(5/package)
10 inch
TFLT10UL12 UL 12 filter replacement
(5/package)
10 inch
Optional Grilles and Replacement Filters
EMC Fan/Grille Upgrade Kit
With the addition of this kit, the cooling fan and exhaust packages
are upgraded to provide EMC (electromagnetic compatibility)
protection. Consult Hoffman for shielding effectiveness (dB
attenuation vs. frequency).
NOTE: Separate kits must be installed on both the inlet and outlet. Cooling fan
and exhaust package must be ordered separately. EMC upgrade kit will not
work with stainless steel grille option.
Catalog Number
Fits Cooling Fan Package
Catalog Number
Fits Exhaust Grille
Catalog Number
T4EMC TFP41/TFP42 TEP4
T6EMC TFP61/TFP62 TEP6
T10EMC TFP101/TFP102 TEP10
Filters
Standard Type 1 air filters are washable foam.
Note: Type 12 air filters are not washable.
Bulletin
MCLY
Filter Fan Packages
TM-48 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Application
Permits densely filtered ambient air to pressurize enclosure so that
ambient air cannot be drawn in through poorly sealed doors, panels,
and wireways. Positive airflow provides a simple and effective way to
protect enclosed electronics from heat and condensation. Ideal for
clean environments.
Construction
Simple, snap-in mounting
Slim fan grille protrudes only .25” or less from enclosure mount
Fan is completely installed inside plastic housing
Housings are made of heat resistant, self-extinguishing ABS; color
RAL 7042 gray (grille only)
Air filter is accessible for cleaning or replacement from outside the
enclosure by simply removing the grille cover
Easy to install. Mounting hardware, full-size mounting template,
drawings, and installation instructions furnished.
Filter Fan Package includes the fan with grille, filter, and filter
sealing gasket. Exhaust Grille Kits are offered for each Filter Fan
Package and must be ordered separately. Filter sealing gaskets are
supplied with both Filter Fan Package and Exhaust Grille Kit to
achieve an IP54 rating.
Industry Standards
UL Component Recognized, UL File Number SF165154
CSA Certified (fan only)
CE
Installation
Fan Package should be mounted near bottom of enclosure with the
exhaust near the top of the opposite side. This will ensure complete
airow distribution through the entire enclosure.
Added Protection
With the supplied filter sealing gasket installed on
both the filter fan package and the exhaust grille
kit, an IP54 rating can be maintained according to
DIN 40050. This rating is defined as protecting
internal electronics from dust, foreign bodies,
and splashing water.
Replacement Filter Sealing Gasket and Filters
Filter Sealing Gasket
Catalog Number Replacement Filter
To Fit Fan Packages
and Exhaust Grille Kits
G050000 10100060 SF0516002
SF0526002
SG0500002
G090000 10100061 SF0916002
SF0926002
SF0900002
G100000 10100062 SF1016002
SF1026002
SG1000002
G130000 10100063 SF1316002
SF1326002
SF1300002
Filtered Cooling
Filter fan packages are appropriate for applications in
which:
The electronic controls can operate at a
temperature differential slightly above the ambient
temperature
Humidity is not a factor
The quality of filtered ambient air is acceptable to
be drawn into the enclosure for cooling
Series SF-05 Filter Fan Package
Bulletin
MCLY
Filter Fan Packages
TM-49
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Thermal
Management
Standard Sizes Filter Fan Packages
Catalog
Number
A x B x C
in. (mm)
Replace-
ment Filter Voltage Hz Phase
Full
Load
Amps
Motor
RPM
Service Temp.
Noise
dB (A)
Ship. Wt. Exhaust
Grille Kit
Model
Number
Air
Flowa Air Flowb
Low
(°F)
Low
(°C)
High
(°F)
High
(°C) (lbs.) (kgs)
SF0516002 5.83 x 5.83 x 2.76
(148 x 148 x 70)
10100060 115 50/60 1 .22 2650/3100 14 -10 131 55 42 1.87 .85 SG0500002 39 29
SF0526002 5.83 x 5.83 x 2.76
(148 x 148 x 70)
10100060 230 50/60 1 .11 2650/3100 14 -10 131 55 42 1.87 .85 SG0500002 39 29
SF0916002 8.03 x 8.03 x 3.78
(204 x 204 x 96)
10100061 115 50/60 1 .22 2650/3100 14 -10 131 55 51 2.56 1.16 SG0900002 75 57
SF0926002 8.03 x 8.03 x 3.78
(204 x 204 x 96)
10100061 230 50/60 1 .11 2650/3100 14 -10 131 55 51 2.56 1.16 SG0900002 75 57
SF1016002 9.84 x 9.84 x 5.20
(250 x 250 x 132)
10100062 115 50/60 1 .53 2760/3030 14 -10 131 55 52 4.39 1.99 SG1000002 162 126
SF1026002 9.84 x 9.84 x 5.20
(250 x 250 x 132)
10100062 230 50/60 1 .30 2760/3030 14 -10 131 55 52 4.39 1.99 SG1000002 162 126
SF1316002 12.72 x 12.72 x 6.09
(323 x 323 x 155)
10100063 115 50/60 1 .89 2550/2800 14 -10 131 55 61 8.38 3.80 SG1300002 376 250
SF1326002 12.72 x 12.72 x 6.09
(323 x 323 x 155)
10100063 230 50/60 1 .45 2550/2800 14 -10 131 55 61 8.38 3.80 SG1300002 376 250
aFree air, CFM
bWith 1 exhaust grille kit, CFM. Order exhaust grille kit separately.
NOTE: Actual airflow may vary depending on system impedence
Series SF-09 Filter Fan Package
Series SF-10 Filter Fan Package
Series SF-13 Filter Fan Package
Bulletin
D85
Outdoor Filter Fan and Exhaust Package
TM-50 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Fans, Blowers,
louvers, and vents
Catalog Number
Enclosure Cutout
Description
External Mounting Depth Internal Mounting Depth
Voltagein. mm in. mm in. mm
AOFF118 4.92 x 4.92 125 x 125 (+.4) Filter Fan 2.56 65 2.44 62 120 VAC, 60 Hz
AOEFG118 4.92 x 4.92 125 x 125 (+.4) Exhaust Filter 2.56 65 0.71 18
NOTE: AOEFG118 does not include a fan.
Replacement Filter
Catalog Number Filter Mat 122 x 122mm
AOFILTER F5 (3 per package)
Standard Sizes Outdoor Filter Fan and Exhaust Package
Application
For use in outdoor or indoor applications where warm air must be
dissipated.
Features
Ball bearing axial fan, service life 50,000 hours at 77˚F (2C) and
65 percent RH
Aluminum fan body, plastic impeller
Airflow 11.8 cfm (20m3/h) free blowing
High-impact plastic is highly weatherproof and resistant to
UV light
F5 filter mat is easy to remove from outside for cleaning and
changing
Lockable door in hood for security
Two-sided tape provided for mounting ease
Filter hood permanently fixed to enclosure from inside using
screws
2 lead wires, 3.94 inches (100mm) long, with pressure clamps,
14 gauge max. (2.5mm)
Synthetic filter material, temperature resistant to 21F (100˚C),
self-extinguishing class F1, moisture resistant to 100 percent RH
Filter mat: Fine grade F5 to DIN EN779
filtering degree: 98 percent of particles larger than 10μm (10
microns)
Finish
Light gray plastic, UL94H-B
Industry Standards
CE
cURus File No. E234324
NEMA Type 3R
IEC/EN 60529, IP55
Rev. A 5/07
Bulletin
D85
Outdoor Filter Fan and Exhaust Package
TM-51
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Thermal
Management
Bulletin
MCLY
Blower Fan Package;
Fan and Blower Accessories
TM-52 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Application
Provides a maximum amount of cooling air while occupying a
minimum of space. Cool air enters through the intake grille and filter
and is discharged into the enclosure. Blower operates on 115 volt
AC, 60/50 Hertz, single phase input power. The unit delivers 275
cubic feet per minute (CFM) of air at zero static pressure.
Performance Curve for ADB275 Blower
Construction
16 gauge steel housing
Attractive stainless steel intake grille is easily removed with two
captive thumbnuts
Washable aluminum filter provides good arrestment of airborne
dirt with minimal pressure drop. Filter has 12 layers of expanded
aluminum which provides hundreds of adhesive-coated bafe
surfaces for trapping dirt and dust particles. (To achieve best
results, Hoffman Filter Adhesive is recommended).
Single phase motor powers the statically balanced blower. Motor is
thermally protected and cooled by incoming forced air.
Direct drive induction motor contains permanently lubricated ball
bearings. Lubricant protects from -20° F to 298° F (-29° C to
148° C).
Rotating components are suspended on neoprene shock-mounts
to minimize noise and vibration
Three-conductor power cord (five feet long) with molded plug is
internally grounded and strain relieved to the body of the fan
Engineered for 20,000 hours of continuous operation when
properly powered
Consult your local Hoffman sales ofce for information on
modifications to this product
Finish
Blower housing is black enamel. Grille is brushed stainless steel.
Industry Standards
UL Component Recognized, UL File Number E61997
EIA RS-310-D
CSA certified (blower motor only)
Accessories
Exhaust Grille and Filter
Filter Adhesive
Temperature Control Switch
Installation
Can be mounted as shown below or installed on standard 19.00
inch (483mm) racks. The unit is self-supporting with 16 gauge steel
flanges notched per EIA RS-310-D. Two openings are required in the
enclosure for air to flow in and out. Refer to drawings for size and
location of openings. An exhaust grille and filter package (catalog
number AEXGR275) is required and must be ordered separately.
Bulletin
MCLY
Blower Fan Package;
Fan and Blower Accessories
TM-53
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Thermal
Management
Located at air discharge side
of an enclosure using Blower
Package ADB275. Polished
stainless steel grille is 65% open
and offers low resistance to
airow. Expanded aluminum
filter (included with each grille) is
easily removed for cleaning from
outside the enclosure. Mounting
hardware is furnished.
Catalog
Number
A x B
(in.)
A x B
(mm)
Filter Size
(in.)
Filter Size
(mm)
AEXGR275 5.75 x 19.00 146 x 483 4.98 x 16.56 126 x 421
AFLTR275AL Aluminum Filter Replacement (5 per package)
Exhaust Grille and Filters for Blower Package
Standard Sizes Blower Fan Package
Catalog
Number
A x B x C
in. (mm)
Free Air
CFM Watts Voltage Hz Amps
Motor
RPM
Noise
SIL (dB)
Weight
(lb.)
Weight
(kg)
ADB275 5.75 x 17.00 x 7.25
(146 x 483 x 184)
230/275 84 115 50/60 1.2 2580/3100 56 15.00 7.00
Bulletin
MCLY
Louvers and Vents
TM-54 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Designed to provide
ventilation in enclosures
where excessive internal heat
or excessive moisture is a
problem. Although louvers
cannot keep all moisture out
of an enclosure, gasketing or
sealing the perimeter of the
louver plate reduces problems
associated with moisture
intrusion. These kits may be
easily installed in the field
by making a cutout of the
proper size and attaching the
louver plate in place. Louver
plates are made from 14 gauge
steel with an ANSI 61 gray
polyester powder finish over
phosphatized surfaces or 316
stainless steel. Hardware is
furnished for mounting. Custom
sizes, materials, finishes, etc.,
can be provided on special
order.
Catalog
Number
A x B
in. (mm)
Number
of
Louvers
Depth
D (in.)
Depth
D (mm)
Length
L (in.)
Length
L (mm)
Opening
Area
sq. in.
Opening
Area
sq. cm
Cutout
Size
F (in.)
Cutout
Size
F (mm)
Cutout
Size
G (in.)
Cutout
Size
G (mm)
AVK23 3.25 x 3.25
(83 x 83)
3 0.19 5 2.00 51 .86 5.54 2.00 51 1.75 44
AVK23SS6 3.25 x 3.25
(83 x 83)
3 0.19 5 2.00 51 .86 5.54 2.00 51 1.75 44
AVK33 3.88 x 4.50
(98 x 114)
3 0.25 6 3.00 76 1.32 8.52 2.62 67 3.00 76
AVK33SS6 3.88 x 4.50
(98 x 114)
3 0.25 6 3.00 76 1.32 8.52 2.62 67 3.00 76
AVK34 4.75 x 4.50
(121 x 114)
4 0.25 6 3.00 76 1.76 11.35 3.50 89 3.00 76
AVK34SS6 4.75 x 4.50
(121 x 114)
4 0.25 6 3.00 76 1.76 11.35 3.50 89 3.00 76
AVK43 4.50 x 5.50
(114 x 140)
3 0.25 6 4.00 102 1.88 12.10 3.25 83 4.00 102
AVK43SS6 4.50 x 5.50
(114 x 140)
3 0.25 6 4.00 102 1.88 12.10 3.25 83 4.00 102
AVK44 5.62 x 5.50
(143 x 140)
4 0.25 6 4.00 102 2.50 16.13 4.38 111 4.00 102
AVK44SS6 5.62 x 5.50
(143 x 140)
4 0.25 6 4.00 102 2.50 16.13 4.38 111 4.00 102
AVK64 5.62 x 7.50
(143 x 191)
4 0.31 8 6.00 152 5.21 33.61 4.38 111 6.00 152
AVK64SS6 5.62 x 7.50
(143 x 191)
4 0.31 8 6.00 152 5.21 33.61 4.38 111 6.00 152
AVK66 7.88 x 7.50
(200 x 191)
6 0.31 8 6.00 152 7.82 50.45 6.62 168 6.00 152
AVK66SS6 7.88 x 7.50
(200 x 191)
6 0.31 8 6.00 152 7.82 50.45 6.62 168 6.00 152
AVK84 5.81 x 9.50
(148 x 241)
4 0.31 8 8.00 203 8.08 52.12 4.56 116 8.00 203
AVK84SS6 5.81 x 9.50
(148 x 241)
4 0.31 8 8.00 203 8.08 52.12 4.56 116 8.00 203
AVK86 8.19 x 9.50
(208 x 241)
6 0.31 8 8.00 203 12.11 78.13 6.94 176 8.00 203
AVK86SS6 8.19 x 9.50
(208 x 241)
6 0.31 8 8.00 203 12.11 78.13 6.94 176 8.00 203
AVK88 10.56 x 9.50
(268 x 241)
8 0.31 8 8.00 203 16.15 104.19 9.31 236 8.00 203
AVK88SS6 10.56 x 9.50
(268 x 241)
8 0.31 8 8.00 203 16.15 104.19 9.31 236 8.00 203
AVK812 15.31 x 9.50
(389 x 241)
12 0.31 8 8.00 203 24.22 156.26 14.06 357 8.00 203
AVK812SS6 15.31 x 9.50
(389 x 241)
12 0.31 8 8.00 203 24.22 156.26 14.06 357 8.00 203
SS6 in catalog number indicates louver plate is Type 316 stainless steel.
Louver Plate Kits
Bulletin
MCLY
Louvers and Vents
TM-55
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
FAns, Blowers,
louvers, And vents
Thermal
Management
Includes a stylized louvered
cover and filter package. Use as
an air inlet when a cooling fan is
mounted in an enclosure or use
two vent kits to allow
passive airow.
Mounting hardware
included. Vent Kit
requires cutout shown in diagram. Available in gray
(RAL 7042) or black.
Catalog Number H x W x D (in.) H x W x D (mm) Color
XPV32 11.81 x 7.88 x 1.03 300 x 200 x 26 Gray
PPV32B 11.81 x 7.88 x 1.03 300 x 200 x 26 Black
Vent Kit
Designed to fit most metallic and
non-metallic enclosures. Proper
installation will provide
rainproof ventilation
but will not meet
Type 4 or 12
requirements. Kit
includes a ventilator
made of fire-retardant
thermoplastic
material, mounting
hardware, and
instructions.
NOTE: Supplied screws are 13mm (.515 inch) long. Some
applications may require longer screws.
Catalog Number Description
ANMV6 Large nonmetallic vent
ANMV3 Small nonmetallic vent
Ventilators
Designed to maximize the efficiency of all expanded aluminum air filters. Use of Filter Adhesive doubles
the dust-retention capacity of the filter. Adhesive contains a low-viscosity water-soluble oil which absorbs
dirt particles trapped on the surface of the filter. Through the circulation of the oil, a renewed impurity-
absorbing surface is constantly established. Washing with water will remove dust, dirt, and other impurities.
Once the filter is dry, re-coat with adhesive.
Catalog Number Description
AFLTAD Spray Adhesive
Filter Adhesive
Designed for use with Louver
Plate Kit. Mounting holes on
filter bracket align with louver
mounting holes. Hardware
supplied with louvers also secure
filter brackets in place. Aluminum
air filters provide good
arrestment of airborne dust and
dirt. Filter media is composed
of layers of slit and expanded
aluminum providing hundreds of adhesive coated bafe surfaces for
trapping impurities. Impurities are held throughout the depth of the
filter. Washing with warm water will keep the filter clean. To achieve
best results, Hoffman Filter Adhesive is recommended.
Catalog
Number A x B (in.) A x B (mm)
Use with Steel
Louver
Use with Stainless
Steel Louver
AFLT33 3.22x 3.25 82 x 83 AVK33 AVK33SS6
AFLT34 4.09 x 3.25 104 x 83 AVK34 AVK34SS6
AFLT43 3.84 x 4.25 98 x 108 AVK43 AVK43SS6
AFLT44 4.97 x 4.25 126 x 108 AVK44 AVK44SS6
AFLT64 4.45 x 6.25 113 x 159 AVK64 AVK64SS6
AFLT66 6.72 x 6.25 171 x 159 AVK66 AVK66SS6
AFLT84 4.64 x 8.25 118 x 210 AVK84 AVK84SS6
AFLT86 7.02 x 8.25 178 x 210 AVK86 AVK86SS6
AFLT88 9.39 x 8.25 239 x 210 AVK88 AVK88SS6
AFLT812 14.14 x 8.25 359 x 210 AVK812 AVK812SS6
Filters for Louver Plate Kits
Bulletin
FAns, Blowers,
louvers, And vents
Filter and Fan Airflow Monitor
D85
TM-56 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Catalog Number
Dimensions
Description
Operating/Storage Temperature
in. mm ˚F ˚C
AAFMCNC 1.34 x 0.71 x 0.31 34 x 18 x 8 Airow Monitor Normally Closed -4.0 to 122 -20 to 50
AAFM120NO 4.72 x 4.72 x 0.39 120 x 120 x 10 Airflow Monitor with 120mm (4 in.)
Grille Normally Open
-4.0 to 176 -20 to 80
NOTE: Maximum Voltage and switching current must not exceed 10 watts. The resulting voltage and current peaks of inductive or capacitive loads must be
restricted by a contact protection circuit.
Standard Sizes Filter and Fan Airow Monitor
Contact resistance, including wire, 370mΩ
2 x single strand AWG 26 connection, 19.69 in. (500mm) long;
0.20 in. (5mm) tip of stranded wire stripped/tinned
Mount with attachment clamp and/or clip or integrated in
protective grille (see drawing)
Mount airflow monitor opening perpendicular to airflow in dust-
free and contamination-free environment
AAFMCNC can be attached directly to Cooling and Exhaust
Package Grilles
AAFM120NO can be attached to any 4-inch standard fan
Finish
Black plastic, UL94H-B
Industry Standards
CE
cURus File No. E250507
UL File No. E250507
Application
Airflow monitor provides simple, reliable method to indicate loss
of airflow of fans. Simple mechanical operation makes these usable
alternatives to electronic monitoring systems.
Features
Bi-directional switch activates an electrical contact if the airflow
of the fan falls below 8.2 ft./sec.
Easy to install
Monitors airow to 164 ft./sec. (50m/s) max.
Construction
Reed/magnet contact
Switching threshold of air flow speed > 8.2 ft./sec. (2.5m/s)
Maximum switching:
capacity = 10W (resistive load)
voltage = NC: DC 240V; NO: DC 60V
current = NC: DC 500mA; NO: DC 170mA
Hysteresis 3.3 ft./sec. (1m/s) fixed
Airflow monitor integrated
in protective grille
Bulletin
FAns, Blowers,
louvers, And vents
D85
Filter and Fan Airflow Monitor
TM-57
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Description Recommended use
NC - Normally Closed
Contact opens when airflow > 8.2 ft./sec.
Use to turn an alarm or signaling device ON
to indicate loss of air flow ( 8.2 ft./sec.)
NO - Normally Open
contact closes when air flow > 8.2 ft./sec.
Use to turn a signaling device ON to
indicate sufcient airflow (> 8.2 ft./sec.)
Bulletin
FAns, Blowers,
louvers, And vents
DataCom Fan Speed Controls
DTHRM
TM-58 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
These Hoffman Fan Speed Controls provide a means to optimize
airow in a cabinet or rack, balancing air volume requirements
with noise level and power use. The AFANTSC Panel Mount Fan
Speed Control adjusts fan speed automatically based on remote
temperature sensor inputs. The A19FANSC 19 in. Rack Mount Fan
Speed Control allows manual control over fan speed. Both units are
designed to work with Hoffman 4-, 6-, and 10-in. Compact Cooling
Fans and with 19 in. fan trays, as well as door- and top-mount fan
trays. These fan speed controls are ideal for ofces, classrooms, and
other acoustic noise-sensitive areas.
Features
AFANTSC Panel Mount Fan Speed Control
Automatically adjusts fan speed depending on remote temperature
sensor input
Temperature sensitivity is field adjustable; preset at 35°C (95°F)
Idle speed and temperature slope are field adjustable
Push-to-reset thermal circuit breaker inside control housing
Compact polycarbonate control housing can be mounted in any
position
NEMA 5-15R outlet provides power to fan
Six ft (1.83m) power cord plugs into standard 120V, 50 or 60 Hz
outlet
Remote probe with 10 ft (3.05m) lead mounts in airow
Mounting brackets included
A19FANSC 19 In. Rack Mount Fan Speed Control
Continuously variable fan speed control knob with minimum speed
adjustment
Uses 1 RU rack space
Steel construction
Two NEMA 5-15R outlets provide power to fan
Six ft (1.83m) power cord plugs into standard 120V 60 Hz outlet
Finish
AFANTSC: Light gray polycarbonate control housing
A19FANSC: RAL 9005 black polyester powder paint
Industry Standards
(both controls)
UL 508A, File No. E249700
cUL C22.2 No. 14, File No. E249700
Bulletin
FAns, Blowers,
louvers, And vents
DTHRM
DataCom Fan Speed Controls
TM-59
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Standard Sizes DataCom Fan Speed Controls
Catalog
Number Description Application
Voltage and
Frequency Current Draw
Temperature Settings
(° C)
Temperature Settings
(° F)
AFANTSC Panel Mount Fan Speed Control Fan speed controlled automatically
with remote temperature sensor
120V, 50/60 Hz 2A max . 30, 35, 40, 45 86, 95, 104, 113
A19FANSC 19 in. Rack Mount Fan Speed Control Fan speed adjusted manually 120V, 60 Hz 4A max . Continuously variable Continuously variable
Bulletin
FAns, Blowers,
louvers, And vents
19 Inch Rack Mount Fan Tray
EC1
TM-60 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Fan trays enhance natural convection airflow within the cabinet
when installed with other 19-in. rack mount equipment. These trays
mount directly to 19-in. rack mounts and occupy one rack unit (1.75
in.) of rack height. They are made of steel with an RAL 9005 black
lightly textured polyester powder paint finish. Order rack mounting
hardware separately.
Construction
Fan trays available with either three or six 4-in. fans
Includes 6 ft (1.83m) power cord with NEMA 5-15P plug
Power cord plugs into standard 115 VAC outlet
Lighted rocker switch provides on-off control and indicates when
fans are on
Finish
RAL 9005 black lightly-textured polyester powder paint
Standard Sizes 19 Inch Rack Mount Fan Tray
Catalog Number Number of Fans Power (watts) Max Airflowa (cfm) C (in.) C (mm)
A19FT3B 3 45 253 8.10 206
A19FT6B 6 90 506 12.96 329
19 Inch Rack Mount Fan Tray with 3 Fans
19 Inch Rack Mount Fan Tray with 6 Fans
a Airflow rating shown appolies to fans before installation in fan tray.
Operating Voltage
(VAC)
Operating
Frequency
(Hz)
Nominal Airow
Capacitya
(CFM)
Noise Level
(dB)
Max. Static
Pressure
(in. WC)
Max. Operating
Pressure
(°F)
Max. Operating
Pressure
(°C)
Power
Consumption
(W)
115 60 102 41 0.27 158 70 15
Technical Performance per 4 in. Fan
Bulletin
FAns, Blowers,
louvers, And vents
D85
Type 3R Fan Shroud Kit
TM-61
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Application
Fan shroud kits are available for outdoor enclosure applications
requiring Type 3R protection from falling rain, sleet, and snow.
Fan shroud kits include two fan shrouds, gasketing, and mounting
hardware. These fan shrouds can be used over any opening that fits
the shroud size.
Features
Shrouds are easily installed over appropriately-sized openings using
the supplied hardware and gasket
Two fan shouds per package to manage intake and exhaust
ventilation
Construction
16 gauge mild steel or Type 304 stainless steel
Perforated ventilation screen
Pressure-sensitive adhesive-backed gasket and mounting hardware
Finish
ANSI 61 gray polyester powder coating over mild steel; smooth #4
brushed finish on stainless steel.
Industry Standards
Maintains UL/cUL Type 3R rating when properly installed on UL/cUL Type 3R
enclosure.
UL 508A Listed, File No. E61997: Type 3R
cUL CSA C22.2 No. 94, File No. E61997: Type 3R
NEMA/EEMAC Type 3R
IEC 60529, IP22
Standard Sizes Type 3R Fan Shroud Kit
Catalog
Number Material
A
(in.)
A
(mm)
B
(in.)
B
(mm)
C1
(in.)
C1
(mm)
C2
(in.)
C2
(mm)
G
(in.)
G
(mm)
H
(in.)
H
(mm)
T4S3R Steel 6.00 152 6.00 152 1.44 37 4.69 119 4.69 119 5.25 133
T6S3R Steel 8.00 203 8.00 203 1.44 37 4.69 119 6.69 170 7.25 184
T10S3R Steel 12.00 305 12.00 305 1.44 37 4.71 120 10.69 272 11.25 286
T4S3RSS Stainless Steel 6.00 152 6.00 152 1.44 37 4.69 119 4.69 119 5.25 113
T6S3RSS Stainless Steel 8.00 203 8.00 203 1.44 37 4.69 119 6.69 170 7.25 184
T10S3RSS Stainless Steel 12.00 305 12.00 305 1.44 37 4.71 120 10.69 272 11.25 286
Catalog
Number
Compact Cooling
(mufn) Fans
Cooling and
Exhaust Fan
Packages Filter Fan Packages
4 in. 6 in. 10 in. TFP4_ TFP6_ SF05_ SF09_ SF10_
T4S3R
T6S3R • •
T10S3R ••••••••
T4S3RSS
T6S3RSS • •
T10S3RSS ••••••••
HeAters
Heaters
Sizing and Selection
TM-62 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
When temperatures dip below the minimally-acceptable ranges for electronics, our electric heaters can raise
the temperature inside enclosures to appropriate levels. Heaters are designed to protect sensitive mechanical,
electrical, and electronic equipment from the harmful effects of condensation and corrosion. Two styles offer
heating powers from10 watts to 800 watts.
The graphs represent a painted steel enclosure mounted in a calm air building interior. The lowest temperature differential between room temperature and
enclosure interior must be 10°F+ to prevent humidity and condensation. For outdoor applications, double the heating power requirement.
Semiconductor Control Panel Heaters (for 10-60 Watt Heating Applications)
Example:
Which electric heater would most efciently maintain a 60°F
temperature in an insulated 24 x 24 x 10 enclosure that is exposed to
a temperature not less than 30°F?
Step 1:
Calculate the total enclosure surface area.
Area (ft. 2) = 2[(AxB)+(AxC)+BxC)] ÷ 144
where “A, “B, and “C” are the dimensions of the enclosure.
In our example,
Area = 2[(24x24)+(24x10)+(24x10)] ÷ 144
Step 2:
Using the graphs, draw a vertical line through the enclosure surface
area and determine the temperature rise given by each heater.
For enclosures exposed to windy conditions, heaters should be
oversized by approximately 50 percent.
Step 3:
Select the electric heater that achieves the desired temperature rise.
In our example, the desired temperature rise is 3F (60°F - 3F).
The 200 watt heater should be selected since its temperature rise
(35°F) exceeds the requirement.
Step 1:
Plot your application using the graph above.
Find surface area (4 ft.2) on the vertical scale
Draw a horizontal line across to the intersection point with the
diagonal line representing ΔT = 4F
Extend a vertical line down to the horizontal scale to determine
your total heating power required (W = 45 watts)
Step 2:
From the total watts required, subtract the 20 watts from pre-
existing components to arrive at the minimum heater power of 25
watts. The 30 watt DAH301 heater should be selected in this case
since it is the nearest size that exceeds the requirement.
Electric Heaters (for 100-800 Watt Heating Applications)
HeAters
Heaters
Sizing and Selection
TM-63
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Semiconductor Control Panel Heaters Catalog Number Watts
DAH101 10
DAH301 30
DAH601 60
Electric Heaters Catalog Number Watts
DAH1001A 100
DAH1002A 100
DAH2001A 200
DAH2002A 200
DAH4001B 400
DAH4002B 400
DAH8001B 800
DAH8002B 800
Bulletin
HeAters
Semiconductor Control Panel
Heaters D85
TM-64 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Designed to meet the demands of electronic, pneumatic,
hydraulic, and mechanical equipment requiring protection from
low temperatures, condensation, and corrosion. The Positive
Temperature Coefficient heater unit will maintain a stable
temperature environment within enclosures, allowing critical
components to perform with consistent reliability for longer periods.
Construction
PTC (Positive Temperature Coefficient) heating element
Mounting clip for 35mm DIN rails EN 50022
Finish
Black anodized extruded aluminum.
Industry Standards
UL Component Recognized
CSA Component Recognized
IEC IP54
CE
Installation
Mount unit at or near the bottom of the cabinet. Improved heat
dissipation will be achieved by using two or more smaller heaters
wired in parallel. If a technical requirement exists for a specific
temperature, regardless of the external ambient temperature, a
thermostat can be installed.
CAUTION: Do not mount on wooden structures. Avoid
placement near heat-sensitive components.
Standard Sizes Semiconductor Control Panel Heaters
Catalog Number Watts Voltage
Amps Starting
Current L (in.) L (mm) Weight (lbs.) Weight (kg)
DAH101 10 AC/DC 110/120 .8 1.97 50 .45 .20
DAH301 30 AC/DC 110/120 1.2 3.93 100 .66 .30
DAH601 60 AC/DC 110/120 2.5 5.5 140 1.10 .50
Bulletin
HeAters
D85
Semiconductor Control Panel
Heaters
TM-65
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Dimensions and Clearance Range for DAH101 and DAH301 Drawing
Dimensions and Clearance Range for DAH601 Drawing
Bulletin
HeAters
Electric Heaters
D85
TM-66 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Designed to protect sensitive mechanical, electrical, and electronic
equipment from the harmful effects of condensation, corrosion, and
low temperatures. Thermostatically-controlled fan-driven heater
units maintain a stable temperature within enclosures so critical
components can perform more reliably over a longer period of time.
Construction
Attractive and durable aluminum housing
Thermostat, standard on all units, is adjustable from 0°F to 10F
(-18°C to 38°C)
Fan draws cool air from the bottom of the enclosure and passes
this air across the thermostat and heating elements before being
released into enclosure cavity
Heated air is discharged through the top of the heater unit
Four 10-32 x self-tapping screws are included with each heater
Ball bearing fan runs continuously for even temperature
distribution
Terminal strip with clamp connector that accepts both solid and
stranded wire
Finish
Brushed aluminum
Industry Standards
UL Component Recognized, UL File No. E61997
CSA Certified, CSA File No. 42186
CE
Installation
Hoffman electric heaters should be centered as low as possible on
an interior enclosure panel. This permits the unit to heat the cool air
located at the bottom of the enclosure. For maximum efficiency and
longevity, the heater should be mounted in a vertical position with
the terminal block to the bottom and the air outlet openings at the
top in a sealed enclosure free from dust or debris. However, the unit
will also effectively distribute heat if turned 90 degrees. Although
enclosure panels are preferable, heaters may be installed on any flat
sheet metal surface.
DO NOT INSTALL HEATERS ON WOOD PANELS.
Heat sensitive components should not be placed near the heater
discharge area since this air can be quite warm. The clearance range
defines the space that must be kept free of these components for
proper and safe operation of the heater.
Standard Sizes Electric Heaters
Catalog Number Watts Voltage Hz Amps Weight (lb.) Weight (kg)
DAH1001A 100 115 50/60 0.98 4.00 181
DAH1002A 100 230 50/60 0.49 4.00 181
DAH2001A 200 115 50/60 1.89 4.00 181
DAH2002A 200 230 50/60 0.95 4.00 181
DAH4001B 400 115 50/60 3.72 6.00 2.72
DAH4002B 400 230 50/60 1.86 6.00 2.72
DAH8001B 800 115 50/60 7.37 6.00 2.72
DAH8002B 800 230 50/60 3.69 6.00 2.72
CAUTION
These electric heaters are not designed for use in
dusty, dirty, corrosive, or hazardous locations. Portions
of the heater can get hot. Adequate protection must
be taken to protect people from potential burns, and
to protect other components from this heat. Hoffman
recommends this heater only be installed in a totally-
enclosed metal enclosure.
DO NOT INSTALL HEATERS ON WOOD PANELS.
Bulletin
HeAters
D85
Electric Heaters
TM-67
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Dimensions and Clearance Range Drawing for DAH1001A, -2A and DAH2001A, -2A
Dimensions and Clearance Range Drawing for DAH4001B, -2B and DAH8001B, -2B
Bulletin
tHermAl ACCessories
Electronic Hygrotherm
D85
TM-68 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Application
Senses ambient temperature and relative air humidity and turns
on or off a connected device if temperature is below or humidity
is above the set point. Integrated LED in each adjustment knob
indicates active function.
Features
Temperature (32º-140ºF) and humidity (50%-90% RH) adjustment
High switching capacity
Optical function displays (LED) in each control
Long service life (100,000 cycles, NO) (50,000 cycles, NC))
Mounting clip for 35mm DIN rail
Change-over contact (relay)
Connection: 5-pole terminal for AWG 14 max. (2.5mm2)
Plastic housing UL94V-0
Vertical mounting
Max. switching capacity:
120 VAC 8A (Resistive Load)
240 VAC 8A (Resistive Load)
120 VAC 3A (Inductive Load)
240 VAC 3A (Inductive Load)
24 VDC 4A
Finish
Light gray plastic, UL94V-0
Industry Standards
CE
cURus File No. E164102
Standard Sizes Electronic Hygrotherm
Catalog Number
A x B x C
Hysteresis
Humidity range
(adjustable)
Operating Temperature
(adjustable) Storage Temperature
in. mm ˚F ˚C ˚F ˚C
ATEMHUM 3.03 x 2.36 x 1.69 77 x 60 x 43 ~ 3.6˚F (2K) ± 1.8ºF (1K) tolerance 50-90% RH 32 to 140 0 to 60 -4 to 176 -20 to 80
Bulletin
tHermAl ACCessories
D85
Electronic Hygrotherm
TM-69
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Input:
Contacts 1 and 2: Supply voltage 120 VAC or 230 VAC
Relay Output:
Contacts 3 and 5 and contacts 4 and 5 (see table)
Contacts Close at... Open at... Use for
3 and 5 humidity rise or
temperature drop
humidity drop or
temperature rise
heaters,
dehumidifiers,
low-temp alarms
4 and 5 humidity drop or
temperature rise
humidity rise or
temperature drop
cooling,
humidifiers,
high-temp alarms
Bulletin
tHermAl ACCessories
Mechanical Hygrostat
D85
TM-70 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Catalog Number
A x B x C Switching Capacity
Operating Temperature
(adjustable) Storage Temperature
in. mm Minimum Maximum ˚F ˚C ˚F ˚C
AMHUM 2.64 x 1.97 x 1.50 67 x 50 x 38 100mA @ AC/DC 20 V 5A @ AC 230 V (resistive load)
0.2A @ AC 230 V
(inductive load at cos Ω = 0.8)
DC 20W
32 to 140 0 to 60 -4 to 176 -20 to 80
Standard Sizes Mechanical Hygrostat
Application
Designed to control relative air humidity inside enclosures. When
connected to an enclosure heater (dehumidifier), it will turn on the
heater at the set humidity level to raise the dew point. Prevents
damage and malfunction of electronic components caused by
condensation and corrosion. Can also be used to control cooling
fans, warning lights, or other devices.
NOTE: The critical relative humidity (RH) for most components is 65 percent.
Above 65 percent RH, condensation can cause malfunction of electronic
equipment.
Features
Adjustable relative humidity range
High switching capacity
Long service life (50,000 cycles)
Maximum permissible air velocity of 50 ft./sec. (15m/s)
Maximum switching voltage = 250 VAC
NOTE: 250 V should be switched only in a non-condensing environment
Change-over contact
Contact resistance <10m
Connection: 3-pole terminal, for AWG 14 max. (2.5mm2)
Mounting clip for 35mm DIN rail
Finish
Light gray plastic, UL94V-0
Industry Standards
CE
Bulletin
tHermAl ACCessories
D85
Dual Thermostat
TM-71
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
Thermal
Management
Catalog Number
A x B x C
Switching Capacity
Setting Range
in. mm Normally Closed Normally Open
ADLTEMP 2.64 x 1.97 x 1.81 67 x 50 x 46 NC: 10A resistive/2A inductive @250 VAC
NO: 5A resistive/2A inductive @250 VAC
DC 30W
32–140 ˚F 32–140 ˚F
Standard Sizes Dual Thermostat
Application
Houses two separate thermostats, allowing independent control of
heating and cooling of equipment. Both thermostats offer a wide
adjustment range and are color coded for easy function recognition.
Features
Two thermostats; one normally closed (NC), red, and one
normally open (NO), blue, in one casing
Wide adjustable temperature range (32º-140ºF)
Wiring terminal easily accessible
Thermostatic bimetallic sensor element
Connection: 4-pole terminal for AWG 14 max. (2.5mm2)
Mounting clip for 35mm DIN rail
Finish
Light gray plastic, UL94V-0
Industry Standards
CE
cURus File No. E164102
CSA File No. 215952
UL File No. E164102
Bulletin
D85
Temperature Control Switches
TM-72 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
tHermAl ACCessories
Application
These easy-to-install thermostats are designed to regulate and
monitor air temperature in enclosures that are set up to operate
with heaters, fans, filter ventilators, heat exchangers, and/or signal
transmitters. Thermostat ATEMNC is specifically designed for use
with heaters (contacts open on temperature rise), while thermostat
ATEMNO is designed to control fans, filter ventilators, or for
switching signal transmitters in the event of overheating (contacts
close on temperature rise). Both thermostats have an adjustable
set point range of 3F to 140°F. An additional label is provided to
convert set point range to degrees Celsius. A preset label is also
provided to cover the set point range label after the thermostat is
put at desired temperature.
When the enclosure reaches the pre-determined set point,
temperature contacts in the thermostat are activated and the fan or
heater begins to operate. Thermostats prolong the life expectancy
of heaters and fans by curtailing their operating hours and also
increase the working efciency of electrical components by exposing
them to fewer contaminants from the surrounding environment.
Connections consist of tubular screw terminals for AWG 14 (0.04
sq. in.). Provision for both panel mounting and DIN rail mounting.
Housing is plastic.
Temperature Control Switches (Thermostats)
Catalog Number Contact Type
ATEMNC NC (normally closed), quick acting
ATEMNO NO (normally open), quick acting
Load Rating
Amp Volts Contact Type
15 120 AC Resistive
16 250 AC Resistive
1 120-250 AC Inductive
10 12-24 DC Resistive
1 12-24 DC Inductive
Temperature Control Switches (Thermostats)
Features
Labels included:
- Additional label for conversion to Celsius scale
- Blank label to cover set point range label when adjustment after
initial setting is not desired
Construction
Bimetal temperature sensor
Plastic housing
Connections consist of tubular screw terminals for
AWG 14 (0.04 sq. in.)
Provision for both panel mounting and DIN rail mounting
Finish
Molded Plastic housing is black
Industry Standards
UL94-VO
Protection rating IEC IP30
UL/cUL Component Recognized, File Number E164102
CSA Certified, File Number 215952
CE
Bulletin
A80
Industrial Corrosion Inhibitors
TM-73
Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • www.hoffmanonline.com © 2007 Hoffman Enclosures Inc.
tHermAl ACCessories
Thermal
Management
Industrial Corrosion Inhibitors
Hoffman corrosion inhibitors protect
Interior components of electrical enclosures, boxes, consoles, and
wireways
Interior components of electronic enclosures
Electrical and electronic equipment and controls
Parts and components that are packaged in crates during shipping
and storage
Switch gear and relay cabinets
Interiors of pipes, conduits, and fuse boxes
Process control computers, instruments, and recording devices
Tool chest interiors and contents
Equipment stored at construction sites
Chief Advantages
Protects against salt and high humidity
Eliminates the need of oiling, plating, or dipping metal
Puts protected equipment to use immediately without degreasing
or coating removal
Provides durable protection for up to 12 months
How They Work
Each inhibitor contains a special chemical combination that vaporizes
and condenses on all surfaces in an enclosed area. Vapors will
redeposit as needed in the event of condensation of moisture on
surfaces. These vapors reach every part of an enclosure, protecting
all interior components. Spraying, wiping, or greasing are not
required. This eliminates precoating, special wraps, and drying
agents. Protection is effective even in salt-water atmospheres. The
AHCI5E and AHCI10E emitters have additional red-metal inhibitors
for further protection. Enclosures containing corrosion inhibitors
must be reasonably sealed.
Life Expectancy and Usage
The normal useful life-span of Hoffman corrosion inhibitors is in
excess of one year. However, inhibitor life expectancy is shortened
by approximately 25% when exposed to temperatures above
104° F (40°C). This product is not recommended for use where
temperature exceeds 199°F. Ventilated enclosures or enclosures not
sealed properly, as well as frequent door openings, also shorten the
product life. Additional inhibitors should be used if these conditions
exist. Since Hoffman corrosion inhibitors are vapor-phase protective,
all surfaces to be protected should be accessible to the vapors. The
maximum distance the vapors can travel is approximately 1.50 feet
(.46 meters). Protection of long narrow enclosures can be achieved
with tape or multiple inhibitors.
Storage and Handling
Each Hoffman corrosion inhibitor is individually packaged in a
resealable bag for maximum effectiveness at the time of usage.
Corrosion inhibitors should be stored at temperatures not exceeding
120°F (45C ). Recommended shelf life under normal conditions is
one year. Hoffman corrosion inhibitors are not returnable. When
determining the proper corrosion inhibitor for your application,
assume the enclosure volume to be protected is greater than
calculated if (1) cabinet doors are opened frequently, (2) cabinet is
located in an extremely corrosive area, and/or (3) cabinet length
divided by depth is greater than four.
AHCI1DV Foam device protects one cubic foot (28 liters) of
enclosure volume for approximately one year.
Size: .25 in. x 1.25 in. x 3.00 ft. (6mm x 32mm x 76mm)
AHCI60R Tape protects sixty cubic feet of enclosure volume per
roll. Use approximately 2.50 in. (6.3cm) of tape per cubic foot
(28 liters) of enclosure volume to be protected. Each roll of tape is
packaged individually in a resealable bag.
Size: .25 in. x .75 in. x 12.00 ft. (6mm x 19mm x 3.6m)
AHCI240R Tape protects 240 cubic feet of enclosure volume per
roll. Use approximately 1.00 in. (2.5cm) of tape per cubic foot
(28 liters) of enclosure volume to be protected. Each roll of tape is
packaged individually in a resealable bag.
Size: .25 in. x 2.00 in. x 20.00 ft. (6mm x 51mm x 6.1m)
AHCI5E Emitter protects five cubic feet (142 liters) of enclosure
volume for approximately one year. Emitters contain additional red
metal (non-ferrous) inhibitors.
Size: 2.50 in. (diameter) x 1.50 in. (high) (63mm x 38mm)
AHCI10E Emitter protects ten cubic feet (283 liters) of enclosure
volume for approximately one year. Emitters contain additional red
metal (non-ferrous) inhibitors.
Size: 2.50 in. (diameter) x 2.00 in. (high) (63mm x 51mm)
AHCI238S Spray is a non-conductive, nonflammable, vapor phase
film and is non-toxic. It has essentially neutral pH value. Application
provides instant protection against corrosion. Spray is water soluble
and can be easily flushed away with water if desired. This product
should be kept from freezing, and has a shelf life of 2+ years in
normal warehouse conditions.
Catalog Number Enclosure Volume Protected
AHCI1DV 1 cu. ft. (28.32 liters)
AHCI5E 5 cu. ft. (141.6 liters)
AHCI10E 10 cu. ft. (283.2 liters)
AHCI60R 60 cu. ft. per roll (1699 liters)
AHCI240R 240 cu. ft. per roll (6797 liters)
AHCI238S Corrosion Inhibitor Spray
Metal Protected by Chemical Unprotected by Chemical
Aluminum Marked reduction of surface attack;
no pitting
Severe surface attack; tarnish; pitting
BrassaDecreased tarnish; very minor surface
attack
Surface discoloration; pitting
Steel, Iron No change Severe corrosion
CopperaSlight staining Heavy corrosive attack
Zinc Plate Slight discoloration Severe corrosion
Tin Plate Slight discoloration Moderate corrosive attack
aAHC15E and AHCI10E emitters are recommended for these materials

Navigation menu