Circuit Breakers For NF Merchandised Panelboards
Class 515
E-frame dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digest page 7-55
Table 9.56: E-frame—125 A, Thermal-magnetic (480Y/277 Vac)
Ampere
Rating
ED, EG, EJ
(480Y/277 Vac)
“D” Interrupting Level
18 kA @ 480Y/277 Vac
“G” Interrupting Level
35 kA @ 480Y/277 Vac
“J” Interrupting Level
65 kA @ 480Y/277 Vac Terminal
Wire Range
Hold Trip Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price
1-pole, 277 Vac
15 A
270 875
EDB14015ab
150.
EGB14015ab
255.
EJB14015ab
408.
AL30FD
#14–#6
Al or Cu
20 A EDB14020ab EGB14020ab EJB14020ab
25 A EDB14025bEGB14025bEJB14025b
30 A EDB14030bEGB14030bEJB14030b
35 A
630 1800
EDB14035b
150.
EGB14035b
225.
EJB14035b
408. AL100FD
#14–2/0
Al or Cu
40 A EDB14040bEGB14040bEJB14040b
45 A EDB14045bEGB14045bEJB14045b
50 A EDB14050bEGB14050bEJB14050b
60 A EDB14060 EGB14060 EJB14060
70 A EDB14070 302. EGB14070 507. EJB14070 812.
2-pole, 480Y/277 Vac c
15 A
270 875
EDB24015b
536.
EGB24015b
776.
EJB24015b
1241.
AL30FD
#14–#6
Al or Cu
20 A EDB24020bEGB24020bEJB24020b
25 A EDB24025bEGB24025bEJB24025b
30 A EDB24030bEGB24030bEJB24030b
35 A
630 1800
EDB24035b
536.
EGB24035b
776.
EJB24035b
1241. AL100FD
#14–2/0
Al or Cu
40 A EDB24040bEGB24040bEJB24040b
45 A EDB24045bEGB24045bEJB24045b
50 A EDB24050bEGB24050bEJB24050b
60 A EDB24060 EGB24060 EJB24060
70 A EDB24070 756. EGB24070 1280. EJB24070 2048.
80 A
1000 2300
EDB24080
756.
EGB24080
1280.
EJB24080
2135. AL100FD
#14–2/0
Al or Cu
90 A EDB24090 EGB24090 EJB24090
100 A EDB24100 EGB24100 EJB24100
110 A EDB24110 1946. EGB24110 2586. EJB24110 3879.
125 A EDB24125 EGB24125 EJB24125
3-pole, 480Y/277 Vac
15 A
270 875
EDB34015b
669.
EGB34015b
1131.
EJB34015b
1358.
AL30FD
#14–#6
Al or Cu
20 A EDB34020bEGB34020bEJB34020b
25 A EDB34025bEGB34025bEJB34025b
30 A EDB34030bEGB34030bEJB34030b
35 A
630 1800
EDB34035b
669.
EGB34035b
1131.
EJB34035b
1358. AL100FD
#14–2/0
Al or Cu
40 A EDB34040bEGB34040bEJB34040b
45 A EDB34045bEGB34045bEJB34045b
50 A EDB34050bEGB34050bEJB34050b
60 A EDB34060 EGB34060 EJB34060
70 A EDB34070 911. EGB34070 1292. EJB34070 2562.
80 A
1000 2300
EDB34080
911.
EGB34080
1292.
EJB34080
2562. AL100FD
#14–2/0
Al or Cu
90 A EDB34090 EGB34090 EJB34090
100 A EDB34100 EGB34100 EJB34100
110 A EDB34110 2421. EGB34110 3216. EJB34110 4826.
125 A EDB34125 EGB34125 EJB34125
EPDs (Equipment Protection Devices), 1-pole, 277 Vac, Thermal-magnetic with 30 mA ground-fault protectiond
15 A
270 875
EDB14015EPDab
1151.
EGB14015EPDab
1256.
EJB14015EPDab
1409. #14–#6 Cu
or
#12–#4 Al
20 A EDB14020EPDab EGB14020EPDab EJB14020EPDab
30 A EDB14030EPDbEGB14030EPDbEJB14030EPDb
40 A 630 1800 EDB14040EPDb1151. EGB14040EPDb1256. EJB14040EPDb1409.
50 A EDB14050EPDbEGB14050EPDbEJB14050EPDb
Note: All EDB, EGB, and EJB circuit breakers are UL Listed as HACR Type. For 50 oC calibration, use a CA suffix. NF branch circuit breakers are fungus proof as standard.
aUL Listed as SWD (Switching duty rated).
bUL Listed as HID (High Intensity Discharge rated).
cUL Listed for use on 240 V Corner-grounded Delta Systems (Grounded B Phase). See data bulletin 2700DB0202.
dAll EPDs occupy two spaces, with or without Alarm Switch option. For alarm switch, add 158 list Price and the suffix BA.
EDB, EGB, EJB
1-pole
15–70 A
EDB, EGB, EJB
2-pole
15–125 A
EDB, EGB, EJB
3-pole
15–125 A
EDB-EPD
1-pole
with Alarm Switch
Table 9.57: Factory installed Electrical Accessories
Auxiliary Switch (1A/1B) Alarm Switch (NO) Coil Burden Max. (VA) Minimum Recommended
Supply Transformer (VA)
288 50
Monitors circuit breaker contact status and provides
a remote signal indicating the circuit breaker
contacts are OPEN or CLOSED.
Application
Max Load = 10 A @ 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire
Used with control circuits and is actuated
only when the circuit breaker has tripped.
Application
Max Load = 7 A @ 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire.
Shunt Trip—Trips the circuit breaker from a remote location by means
of a coil energized from a separate circuit. A 120 V shunt trip will
operate at 55% or more of rated voltage.
Application
For use with momentary or maintained push button. 120 Vac 50/60 Hz
Terminals for #14 AWG Cu wire.
Table 9.58: Factory Installed Electrical Accessory Packages for
ED, EG, EJ Circuit Breakers
Accessory Package Suffix $ Price
Auxiliary Switch/Alarm Switch Packageef AABA 312.
Shunt Trip Packageef SA 755.
Auxiliary Switch/Alarm
Switch/Shunt Trip Packageef AABASA 1067.
Alarm Switch (N.O.) Package for EPDs only BA 237.
eAccessory package takes an additional pole space.
fNot available for EPD.
Table 9.59: Terminal Nut Insert Kit
Circuit Breaker Type Qty. per Kit Catalog No. $ Price
ED, EG, EJ 3 TIKFD 17.40
Table 9.60: Handle Accessories
Circuit Breaker Type No. of Poles Catalog No. $ Price
EXB Fixed Padlock Attachment, Lock ON/OFF
ED, EG, EJ 1, 2, or 3 EDPA 39.00
EXB Fixed padlock attachment, Lock OFF only
ED, EG, EJ 1, 2, or 3 EDPAF 45.00
EXB Removable padlock attachment, Lock OFF only
ED, EG, EJ 1, 2, or 3 HPAFD 25.50
EXB Handle Ties
ED, EG, EJ Ties 2 – 1P ECB2HT 16.80
Ties 31P ECB3HT 17.85
Table 9.61: Interrupt Ratings (kA)
EDB EGB EJB
120 V 25 65 100
240 V 18 (1P), 25 35 (1P), 65 65 (1P), 100
480Y/277 V 18 35 65
Table 9.62: Mechanical Lug Kit Information (Al lugs for use with Al or Cu wire)
Circuit Breaker Application Number of Wires Per Lug
and Wire Range Catalog Number Lugs
Per Kit
$ price
Per Kit
Standard Ampere Rating Optional Ampere Rating
EDB, EGB, EJB
15–30 A one #12—#6 AWG Al or
one #14—#6 AWG Cu AL30FD 3
41.30
35–125 A EDB, EGB, EJB 15–30 A gone #12—2/0 AWG Al or
one #14—2/0 AWG Cu AL100FD 3
EDB, EGB, EJB 15–125 A one #14—1/0 AWG Cu CU100FD 3
gFactory installed only. Use suffix “LH”