Meltric DSN Decontactor Plugs And Receptacles Brochure

104796-Attachment 104796-Attachment 104796-Attachment 784474 Batch5 unilog cesco-content

2014-05-16

: Pdf 556155-Brochure 556155-Brochure 784474 Batch2_1 unilog

Open the PDF directly: View PDF PDF.
Page Count: 8

23
Features and Ratings p. 24
DSN20 p. 25
DSN30 p. 27
DSN60 p. 29
Spare parts p. 31
Dimensions p. 33
Switch rated plugs and receptacles
with NEMA 4X protection
DSN Series products are switch and hp rated for quick, safe equipment changeouts. DSNs
are ideal for wet environments since they offer NEMA 4X watertightness as soon as the plug
is latched to the receptacle or as soon as the receptacle lid is closed.
Main Advantages
Switch & Hp rated (AC only)
100 kA short circuit rated*
NEMA 4X, IP66+IP67
Compact, lightweight design
Up to 4 auxiliary contacts
DECONTACTORTM Series Switch Rated Plugs & Receptacles DSN
Simplify Compliance to
NFPA 70E & CSA Z462
Highlighted Advantage
* See note under General Ratings on the next page
See pgs 19-20 for
more information
Typical Device Labels
Meltric DSN30
30A, TYPE 4X
10 HP, 480VAC
63-34043
SWITCH RATED RECEPTACLE/CONNECTOR
MOTOR CIRCUIT DISCONNECT SWITCH
BRANCH CIRCUIT DISCONNECT SWITCH
LISTED 49B6
08L10
Highlighted Feature
DSN Decontactors are UL & CSA rated for
“motor circuit” and “branch circuit” disconnect
switching – up to 20 hp and up to 60A
Category UL CSA IEC
Plugs and Receptacles UL 1682 C22.2 No. 182.1 60309-1
Branch Circuit Disconnect Switching UL Subject 2682 UL Subject 2682
(AC only) (Performance tests from UL 98)
Motor Circuit Disconnect Switching UL Subject 2682 UL Subject 2682
(AC only) (Performance tests from UL 508)
Amperage 20 to 60A
Voltage 600 VAC*
Frequency 50-400 Hz
Horsepower 1/2 to 20 hp
Short-Circuit
(Make & Withstand)
Environmental NEMA 4X, IP66+IP67
Temperature min -40°F/max 140°F
60947-3, AC22, AC23
Product Features
1
3
2
4
The plug and the receptacle
are separated. The safety
shutter prevents access to
live parts.
Rotating the ‘dead’ plug
30° counterclockwise
closes the safety shutter
and frees the plug to be
withdrawn from the
receptacle.
When the plug and recep-
tacle are latched together,
the circuit is connected.
Pressing the pawl causes
the DECONTACTOR to
break the circuit. The
plug is ejected to its rest
position; its contacts are
now dead.
To reconnect, insert
plug into receptacle,
rotate 30° clockwise, and
apply insertion force.
5
General Ratings
Listings
100kA**
* DSN20 devices are 480 VAC
** Testing was performed with RK1 current limiting fuses
sized at 400% or more of the highest full load motor
ampacity associated with the devices horsepower ratings.
Dead Front Safety Shutter
Assures safety by preventing
user access to live parts.
Silver-Nickel Contact Material
Solid silver-nickel contact surfaces
provide superior conductivity, durability
and corrosion resistance.
Casing
Fiberglass reinforced thermo-
plastic polyester material
offers great resistance to
impact, corrosion and harsh
environmental conditions.
OFF Button
Press to deenergize. Provides
push button circuit disconnection.
Lid
Provides additional
protection from harsh
environments.
Spring Loaded Butt-Style Contacts
Ensures optimal contact force and
superior electrical performance
over thousands of operations.
Spring Assisted Screw Terminals
Patented design assures “Tighten
and Forget” confidence.
Lockout-Tagout Provisions
Allows plug to be easily locked out and
tagged. Optional Padlock Pawl allows
lockout/tagout of the receptacle.
Operating
Instructions
CE ratings available upon request
DECONTACTORTM Series Switch Rated Plugs & Receptacles
24
Receptacle (female) Inlet (male)
DECONTACTOR20A
Switch Rated Plugs & Receptacles
25
Ratings
Straight Insertion Recept # - A188 Self-Ejecting Plug Release Inlet # - 338-A188
Self-Ejecting Connector Release Recept # - 345-A188 Straight Insertion Inlet # - A188
Mushroom Pawl Recept # - 375 With No Lockout Hole Inlet # - A155
Padlock Pawl Recept # - 843
Padlockable Mushroom Pawl Recept # - 375-843
Closed Lid Configuration Recept # - NC
3P+N+G 63-14167 3P+N+G 63-18167
1P+N+G 63-14075 1P+N+G 63-18075
2P+N+G 63-14076 2P+N+G 63-18076
2P+G 63-14162 2P+G 63-18162
3P+G 63-14163 3P+G 63-18163
2P+G 63-14072 2P+G 63-18072
3P+G 63-14073 3P+G 63-18073
1P+N+G 63-14045 1P+N+G 63-18045
3P+N+G 63-14047 3P+N+G 63-18047
3P+N+G – 3P+N+G –
2P+G 63-14042 2P+G 63-18042
3P+G 63-14043 3P+G 63-18043
2P+G – 2P+G –
3P+G – 3P+G –
Part # Part #
Poly Poly
Receptacle Options Suffix # Inlet Options Suffix #
208V
208V
125V
277V
250V
250V
600V
600V
480V
480V
120/208V
125/250V
277/480V
347/600V
208V
208V
125V
277V
250V
250V
600V
600V
480V
480V
120/208V
125/250V
277/480V
347/600V
Main Options
Voltage Polarity Voltage Polarity
DECONTACTORTM Series Switch Rated Plugs & Receptacles
Mushroom
Pawl
Padlock Pawl
DSN20 Order Example:
To order a receptacle with a padlock pawl add
-843
the receptacle part number.
DSN20 receptacle 3P+G= 63-14043
-843
Appropriate accessory numbers must also be
included on the order
Don’t forget to
add installation
accessories to
your order
See pgs 187-196 for detailed
information on these options
Other voltage configurations are available – contact customer service at 800.433.7642.
240V
240V
120V
208V
480V
• Voltage
480 VAC
Switch Rating (AC Only)
Branch Circuit & Motor Circuit
Disconnect Switching
Horsepower Ratings
1/2 hp
1 hp
2 hp
2 hp
5 hp
Short Circuit Rating
100kA Close & Withstand
Testing was performed with RK1
current limiting fuses sized at 400%
of the highest full load motor ampacity
associated with the devices hp rating.
Environmental Ratings
NEMA 4X, IP66+IP67
Temperature Range
Min -40°F/Max 140°F
See pg 210 for temps below -15°F.
Wiring Capacity
Min 14 AWG Max 12 AWG
• Listings
UL, CSA, IEC, CE*
*Contact Customer Service
++
Receptacle and
Accessories
Angle, Handle, etc are interchangeable (see opposite page)
Inlet
(see above)
How to Order
Closed Lid
Configuration
Recommended for
cord applications
to keep lid tucked
in to avoid damage.
DSN20
DECONTACTORTM Series Switch Rated Plugs & Receptacles
Installation Accessories
26
Poly Nylon Extended Angled
Handle Handle Handle Handle
Nylon 30° Metal 30° Nylon 30° Metal 30° Angle/ Metal Straight
Angle Angle Angle for MB Box Adapter Plate for FS Box Adapter
1/2” 61-1A013-12 .20 - .83 61-1A413
3/4” 61-1A013-34 .35 - .69 61-1A013 61-1A313
1” 61-1A013-1
Handles
Angles
Miscellaneous Accessories
Junction Boxes
* Set of Two (2)
61-1A027 MA1 61-1A027-601 MAFS1* MS1
Finger Protective Padlockable
Drawplates Cap Plug Cap
61-1A346 61-1A126 61-1A826
1/2” MB312 61-1A053-080-12 61-1A023-12 51-AA058
3/4” MB334 61-1A053-080-34 61-1A023-34 51-AA058
1” MB31 61-1A053-080-1 51-AA058
1 1/4” MB3114 61-1A053-080-114 51-AA058
Metal Metal Box with Poly* Poly 70°**
Box Nylon Angle Conduit Entry Wall Box
Notes: Finger draw plates are recommended for easier connector closure on cord to cord assemblies.
For available cord grips, see pgs 183-184.
* Recommended for cord to cord assembly applications, for easier connector closure
NPT Cable Range
NPT
For Male
Devices Only
Order Example
A typical order should include an inlet
part number, a receptacle part number
AND the matching handles, angles or
other required accessories.
Male Inlet with Handle (Plug)
63-18043 + 61-1A013
Female Receptacle with Angle Adapter
63-14043 + 61-1A027
For Male
Devices Only
Specialty Products Spotlight
Angle for MB3 Box
Nylon 30° angle facilitates the mounting of
DSN20 to a MB3 box. Each kit includes a
nylon 30° angle, angle gasket and a pack
of four screws.
For a guideline of NPT sizes based on
cable ranges, see DSN3 on pg 28.
DSN20
* For poly devices only
** UL pending. 70° boxes are not drilled. Contact customer service if factory drilling is required.
+Interior volume with receptacle installed.
* Includes angle, adapter plate and gaskets for FS box mounting
MB3 Box & Mounting
Screws not included
Angle
Gasket
Nylon 30°
Angle
29.8 in3+ 6.7 in3+ 84.0 in3+
Receptacle (female) Inlet (male)
DECONTACTOR30A
Switch Rated Plugs & Receptacles
27
Ratings
With 2 Auxiliary /Pilot Contacts Recept # - 972 With 2 Auxiliary/Pilot Contacts Inlet # - 972
Straight Insertion Recept # - A188 Self-Ejecting Plug Release Inlet # - 338-A188
Self-Ejecting Connector Release Recept # - 345-A188 Straight Insertion Inlet # - A188
Mushroom Pawl Recept # - 375 With No Lockout Hole Inlet # - A155
Padlock Pawl Recept # - 843 For Auxiliary Switch* Inlet # - NNF
Padlockable Mushroom Pawl Recept # - 375-843
Closed Lid Configuration Recept # - NC
With Auxiliary Switch Recept # - 270+
3P+N+G 63-34167 3P+N+G 63-38167
1P+N+G 63-34075 1P+N+G 63-38075
2P+N+G 63-34076 2P+N+G 63-38076
2P+G 63-34162 2P+G 63-38162
3P+G 63-34163 3P+G 63-38163
2P+G 63-34072 2P+G 63-38072
3P+G 63-34073 3P+G 63-38073
1P+N+G 63-34045 1P+N+G 63-38045
3P+N+G 63-34047 3P+N+G 63-38047
3P+N+G 63-34147 3P+N+G 63-38147
2P+G 63-34042 2P+G 63-38042
3P+G 63-34043 3P+G 63-38043
2P+G 63-34142 2P+G 63-38142
3P+G 63-34143 3P+G 63-38143
Part # Part #
Poly Poly
Receptacle Options Suffix # Inlet Options Suffix #
208V
208V
125V
277V
250V
250V
600V
600V
480V
480V
120/208V
125/250V
277/480V
347/600V
208V
208V
125V
277V
250V
250V
600V
600V
480V
480V
120/208V
125/250V
277/480V
347/600V
Main Options
Auxiliary/Pilot
Contacts
Voltage Polarity Voltage Polarity
DECONTACTORTM Series Switch Rated Plugs & Receptacles
• Voltage
600 VAC
Switch Ratings (AC Only)
Branch Circuit & Motor Circuit
Disconnect Switching
Horsepower Ratings
1 hp
3 hp
5 hp
5 hp
10 hp
15 hp
Short Circuit Rating
100kA Close & Withstand
Testing was performed with RK1
current limiting fuses sized at 400%
of the highest full load motor ampacity
associated with the devices hp rating.
Environmental Ratings
NEMA 4X, IP66+IP67
Temperature Range
Min -40°F/Max 140°F
See pg 210 for temps below -15°F.
Wiring Capacity
Min 14 AWG Max 8 AWG
Aux Contacts - Max 14 AWG
• Listings
UL, CSA, IEC, CE*
*Contact Customer Service
240V
240V
120V
208V
600V
480V
Mushroom
Pawl
Padlock Pawl
Closed Lid
Configuration
See pgs xxx-yyy for detailed
information on these options
DSN30 Order Example:
To order 2 auxiliary contacts on an inlet and receptacle
add
-972
to the part numbers.
DSN30 Inlet 3P+G = 63-38043
-972
DSN30 Receptacle 3P+G = 63-34043
-972
Appropriate accessory part numbers must also be
included on the order.
Don’t forget to
add installation
accessories to
your order
See pgs 187-196 for detailed
information on these options
Other voltage configurations are available – contact customer service at 800.433.7642.
Recommended for
cord applications
to keep lid tucked
in to avoid damage. ++
Receptacle and
Accessories
Angle, Handle, etc are interchangeable (see opposite page)
Inlet
(see above)
How to Order
Notes:
*Order inlet with P+N+G configuration and receptacle with
P+G configuration
Notes:
+Not UL /CSA Listed
DSN30
Cable Range NPT
.062 - .5 1/2”
.187 - .75 3/4”
.437 - 1.10 1”
.750 - 1.375 1 1/4”
NPT Guidelines
NPT sizes are determined by the
cable diameter and third party
cord grip.
DECONTACTORTM Series Switch Rated Plugs & Receptacles
Installation Accessories
28
Poly Nylon Poly Handle
Handle Handle w/Clamp & Bushing
Nylon 30° Metal 30° Metal Angle Metal Straight
Angle Angle FS/ FD Box 30° Adapter
Handles
Angles
Miscellaneous Accessories
Junction Boxes
* Set of Two (2)
61-3A027 MA2 MAFS2 MS2
Finger Protective Padlockable
Drawplates Cap Plug Cap
61-3A346 61-3A126 61-3A826
1/2” MB312 61-3A053-080-12 61-3A023-12 51-BA058
3/4” MB334 61-3A053-080-34 61-3A023-34 51-BA058
1” MB31 61-3A053-080-1 51-BA058
1 1/4” MB3114 61-3A053-080-114 51-BA058
Metal Metal Box with Poly* Poly 70°**
Box Nylon Angle Conduit Entry Wall Box
Notes:
Finger draw plates are recommended for easier connector closure on cord to cord assemblies.
For available cord grips, see pgs 183-184.
* Recommended for cord to cord assembly applications, for easier connector closure
NPT Cable Range
NPT
For Male
Devices Only
1/2” 61-3A013-12 .20 - .83 61-3A013
3/4” 61-3A013-34 .750 - .875 1PM514
1” 61-3A013-1 .875 - 1.000 1PM516
1 1/4” 61-3A013-114 1.000 - 1.125 1PM518
1.125 - 1.250 1PM520
1.250 - 1.375 1PM522
Order Example
A typical order should include an inlet
part number, a receptacle part number
AND the matching handles, angles or
other required accessories.
Male Inlet with Handle (Plug)
63-38043 + 61-3A013
Female Receptacle with Angle Adapter
63-34043 + 61-3A027
DSN30
For Male
Devices Only
* For poly devices only
** 70° boxes are not drilled. Contact customer service if factory drilling is required.
+Interior volume with receptacle installed.
Specialty Products Spotlight
Poly 70° Wall Box
Entries and exits can be drilled in the field
using pilot holes at top, bottom or sides.
Large box size makes wiring easy. 70°
angle reduces protrusion and minimizes
impact risk.
28.7 in3+ 8.5 in3+ 85.0 in3+
Receptacle (female) Inlet (male)
DECONTACTOR60A
Switch Rated Plugs & Receptacles
29
Ratings
With 2 Auxiliary /Pilot Contacts Recept # - 972 With 2 Auxiliary/Pilot Contacts Inlet # - 972
With 3 Auxiliary /Pilot Contacts Recept # - 973+With 3 Auxiliary/Pilot Contacts Inlet # - 973+
With 4 Auxiliary /Pilot Contacts Recept # - 974+With 4 Auxiliary/Pilot Contacts Inlet # - 974+
Straight Insertion Recept # - A188 Self-Ejecting Plug Release Inlet # - 338-A188
Self-Ejecting Connector Release Recept # - 345-A188 Straight Insertion Inlet # - A188
Mushroom Pawl Recept # - 375 With No Lockout Hole Inlet # - A155
Padlock Pawl Recept # - 843 For Auxiliary Switch* Inlet # - NNF
Padlockable Mushroom Pawl Recept # - 375-843
Closed Lid Configuration Recept # - NC
With Auxiliary Switch Recept # - 270+
3P+N+G 63-64167 3P+N+G 63-68167
1P+N+G 63-64075 1P+N+G 63-68075
2P+N+G 63-64076 2P+N+G 63-68076
2P+G 63-64162 2P+G 63-68162
3P+G 63-64163 3P+G 63-68163
2P+G 63-64072 2P+G 63-68072
3P+G 63-64073 3P+G 63-68073
1P+N+G 63-64045 1P+N+G 63-68045
3P+N+G 63-64047 3P+N+G 63-68047
3P+N+G 63-64147 3P+N+G 63-68147
2P+G 63-64042 2P+G 63-68042
3P+G 63-64043 3P+G 63-68043
2P+G 63-64142 2P+G 63-68142
3P+G 63-64143 3P+G 63-68143
Part # Part #
Poly Poly
Receptacle Options Suffix # Inlet Options Suffix #
208V
208V
125V
277V
250V
250V
600V
600V
480V
480V
120/208V
125/250V
277/480V
347/600V
208V
208V
125V
277V
250V
250V
600V
600V
480V
480V
120/208V
125/250V
277/480V
347/600V
Main Options
Auxiliary/Pilot
Contacts
Voltage Polarity Voltage Polarity
DECONTACTORTM Series Switch Rated Plugs & Receptacles
• Voltage
600 VAC
Switch Ratings (AC Only)
Branch Circuit & Motor Circuit
Disconnect Switching
Horsepower Ratings
2 hp
3 hp
7 1/2 hp
7 1/2 hp
20 hp
20 hp
Short Circuit Rating
100kA Close & Withstand
Testing was performed with RK1
current limiting fuses sized at 400%
of the highest full load motor ampacity
associated with the devices hp rating.
Environmental Ratings
NEMA 4X, IP66+IP67
Temperature Range
Min -40°F/Max 140°F
See pg 210 for temps below -15°F.
Wiring Capacity
Min 12 AWG Max 4 AWG
Aux Contacts - Max 14 AWG
• Listings
UL, CSA, IEC, CE*
*Contact Customer Service
240V
240V
120V
208V
600V
480V
Mushroom
Pawl
Padlock Pawl
DSN60 Order Example:
To order 2 auxiliary contacts on an inlet and receptacle
add
-972
to the part numbers.
DSN60 Inlet 3P+G = 63-68043
-972
DSN60 Receptacle 3P+G = 63-64043
-972
Don’t forget to
add installation
accessories to
your order
See pgs 187-196 for detailed
information on these options
Other voltage configurations are available – contact customer service at 800.433.7642.
Notes:
+Not UL /CSA Listed
++
Receptacle and
Accessories
Angle, Handle, etc are interchangeable (see opposite page)
Inlet
(see above)
How to Order
Notes:
*Order inlet with P+N+G configuration and receptacle with
P+G configuration
Closed Lid
Configuration
Recommended for
cord applications
to keep lid tucked
in to avoid damage.
DSN60
Accessory Spotlight
Finger Drawplates
Finger drawplates are recommended for
easier connector closure on cord to cord
assemblies.
DECONTACTORTM Series Switch Rated Plugs & Receptacles
Installation Accessories
30
Poly Nylon Poly Handle Poly Handle
Handle Handle w/Clamp & Bushing w/built in Draw Grips
Nylon 30° Metal 30° Metal 70° Metal Angle Metal Straight
Angle Angle Angle FS/FD Box 30° Adapter
1/2” 61-6A013-12 .39 - 1.18 61-6A013 61-6A473
3/4” 61-6A013-34 .750 - .875 3PM514
1” 61-6A013-1 .875 - 1.000 3PM516
1 1/4” 61-6A013-114 1.000 - 1.125 3PM518
1.125 - 1.250 3PM520
1.250 - 1.375 3PM522
Handles
Angles
Miscellaneous Accessories
Junction Boxes
Set of Two (2) For Male
Devices Only
61-6A027 MA3 89-3A027 MAFS3 MS3
Finger Protective Padlockable Cord Grip
Drawplates Cap Plug Cap w/ Mesh
61-6A346 61-6A126 61-6A826 see pgs 183-184
1/2” MB312 61-6A053-080-12 61-6A023-12 51-CA058
3/4” MB334 61-6A053-080-34 61-6A023-34 51-CA058
1” MB31 61-6A053-080-1 61-6A023-1 51-CA058
1 1/4” MB3114 61-6A053-080-114 51-CA058
Metal Metal Box with Poly* Poly 70°**
Box Nylon Angle Conduit Entry Wall Box
Notes:
Finger draw plates are recommended for easier connector closure on cord to cord assemblies.
For available cord grips, see pgs 183-184.
For a guideline of NPT sizes based on
cable ranges, see DSN3 on pg 28.
NPT Cable Range
NPT
For Male
Devices Only
Order Example
A typical order should include an inlet
part number, a receptacle part number
AND the matching handles, angles or
other required accessories.
Male Inlet with Handle (Plug)
63-68043 + 61-6A013
Female Receptacle with Angle Adapter
63-64043 + 61-6A027
DSN60
Makes connector
closures easier
* For poly devices only
** 70° boxes are not drilled. Contact customer service if factory drilling is required.
+Interior volume with receptacle installed.
29.6 in3+ 13.5 in3+ 185.7 in3+

Navigation menu