Contactors, Starters, Two-speed Controllers

Table Of Contents
Introduction .............................................................2

.c
om

Reliable Contactors, Starters, and Two-speed Controllers
With Broad Industry Acceptance

ua
ls

Definite Purpose Controls-Description .......................................3
Contactors:
20-, 25-, and 30-ampere, One- and Two-pole, Compact Design ..................4
25-, 30-, and 40-ampere, Two-, Three-, and Four-pole .........................5
50- and 60-ampere, Two- and Three-pole ...................................6
75- and 90-ampere, Two- and Three-pole ...................................7
120- and 150-ampere, Two- and Three-pole ... . .. ... . . .. ... ... . ... .. .. .. ....8

an

Starters:
25-, 30-, and 40-ampere, Single- and Three-phase ............................9
50- and 60-ampere, Single- and Three-phase ...............................10

Two-speed Controllers:
25-, 30-, and 40-ampere ................................................11
50-, 60-, 75-, and 90-ampere ............................................12

tM

Technical Data:
Technical Data Table ..................................................13
ULand CSA References ................................................13
Shipping Weights .....................................................13
Heater Selection Information ...........................................14-15

ar

Field Installation Kits .....................................................16
Dimensions .........................................................17-22

lP

Quality Products For All Your Control Needs .................................23

Introduction :

ca

Serving industry for over 30 years, GE continues to offer

definite purpose control components that provide the depen­
dability required on today's air conditioning, heating and

refrigeration, data processing, power supply, food processing,
agricultural, and other industrial equipment.Contactors,

tri

starters, and 2-speed controllers reflect quality materials and

workmanship resulting in products with broad industry accep·

tance.Backed by design knowledge and experience, GE definite
purpose components offer high reliability for a wide variety of
tified by CSA.

lec

applications.All carry UL component recognition and are cer·

Look at these customer-oriented features and benefits:

•

Universal mounting plate with multiple holes makes it easy to
interchange with other manufacturers' devices.

.E

• Bold, easy-to-read terminal markings simplify installation and
field maintenance.

• Straight-through wiring helps speed installation.
•

Wiring time is reduced because it is not necessary to loop or
bend leads around the device.

w

• Connections are further simplified with standard combination

ww

screw and quick-connect power and coil terminals.

2

•

Moisture-resistant coils protect contactors from dirt and
moisture.

• Precision, self-aligning magnets add to quiet, dependable
•
•

operation.
Inspection of durable, double-break contacts is performed
easily without removal of contactor.

Housing design offers high arc tracking resistance and dielectric strength.

• Corrosion-resistant materials used throughout.

• Arc confining cover (except CR353C compact design).

•
•

Replaceable contacts and coils (except for CR353C compact
design).
New Class B coil for higher ambient operation on contactors
up to 60 FLA.

This bulletin provides detailed technical information for easy,
accurate selection of all GE definite purpose controls.
Simplified charts for all basic models include all available fac­
tory modification for your exact requirements.Field modifica­
tion kits and replacement parts are also included for easy
selection.

• 20 through 150 ampere.
• 600-volt rated.

.c
om

Contactors

• Silver cadmium oxide contacts for dependable service and
long life.

• Molded coils to protect against damage and resist moisture.CD

ua
ls

• Arc confining cover also protects against contimants. CD
• Standard terminations:

- Binding head screw with double quick connect terminals
on 20·, 25·, and 30-ampere ratings.

-Box lugs with double quick connect terminals on 40·
through 90-ampere ratings.

-Pressure connectors on 120- and 150-ampere ratings.

an

• Replaceable coil and contacts. CD
• Clearly visible nameplates.
• Enclosure kits available.CD

CD Does not apply to CR353C contactors.

tM

Starters

• 25- through 50-ampere.
• 600-volt rated.

ar

• Single- and 3-phase forms.

• Standard or ambient compensated overload relays.

• 25- through 90-ampere.
• 600-volt rated.

• For single- or two-winding motor application.

• Standard features include mechanical and cross-electrical
interlocking.

ww

w

.E

lec

Two-speed Controllers

tri

ca

lP

• Straight through wiring.

• Enclosure kit available.

3

.c
om

20-, 25-, and 30-ampere, 1- and 2-pole Compact Design

-

Open Type

ua
ls

CR353
1-pole

Standard
Open Type

Ampere Ratings
Inductive
Full Load

277V

480V

600V

Resistive
Per Pole

20
25
30

120
150
150

100
125
125

80
100
100

30
35
40

Catalog
Number
CR353CA1A*1
CR353CB1A*1
CR353CC1A*1

an

Locked RotorCD

1-pole Plus Shunted Pole
Ampere Ratings

20
25
30

277V

480V

600V

Resistive
Per Pole

120
150
150

100
125
125

80
100
100

30
35
40

Standard
Open Type
Catalog
Number

2-pole

Ampere Ratings

CR353CA3A*1
CR353CB3A*1
CR353CC3A*1

277V

480V

600V

Resistive
Per Pole

20
25
30

120
150
180

100
125
150

80
100
120

30
35
40

lP

* Insert letter from Coil Selection Table below.
CD Refer to page 13 for stalled rotor recycle ratings.

Locked RotorCD

Inductive
Full Load

ar

Inductive
Full Load

Locked RotorCD

tM

* Insert letter from Coil Selection Table below.
CD Refer to page 13 for stalled rotor recycle ratings.

Standard
Open Type
Catalog
Number
CR353CA2A*1
CR353CB2A*1
CR353CC2A*1

* Insert letter from Coil Selection Table below.

CD Refer to page 13 for stalled rotor recycle ratings.

Inrush VA
(Nominal)

Voltage

Letter
Code

c

50Hz

24
110-120
208-240
277
440-480

24
110
208-220

Sealed VA
(Nominal)

Sealed Watts
(Nominal)

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

35
42
42
42
42

42
50
50
50
50

7.0
8.5
8.5
8.5
8.5

8.5
10.2
10.2
10.2
10.2

3.0
3.6
3.6
3.6
3.6

3.2
3.85
3.85

tri

A
B
F

60Hz

-

380-440

lec

H

ca

AC Coil Selection Table

-

3.85

Resistance
Ohms ± 10%
11
210
790
1240
3550

Factory Modifications

.E

Terminals:

Change letter in 9th position (CR353CA2AH1)
Binding Head Screw

With Quick Connect Terminals ......................A

Screw with Pressure Plate

w

With Quick Connect Terminals . . . . . . . . . . . . . . .. . . . .. . E

Auxiliary Contacts:
Letter "A" in 12th position (CR353CA2AH1A)
Indicates no auxiliary contacts. If auxiliary contacts are re­
quired, refer to CR353A forms. Omit "A" if customer part
number is not required.

Customer Part Number:

Add letter in 13th position (CR353CA2AH1AB)

ww

Terminal Markings:
Number "1" in 1 1th position (CR353CA2AH 1)
Indicates Line ("L") markings at Top/Load ("T") markings
at bottom

4

Customer Part Number on device and carton label

.

. . .B

.c
om

20-, 30-, and 40-ampere, 2-, 3- and 4-pole

Open Type

Ampere Ratings
Inductive
Full Load

Locked Rotor

Standard
Open Type

Number
Of
Poles CD

Resistive
Per Pole

ua
ls

-

Catalog
Number

480V

600V

25

150

125

100

35

2
3
4

CR353AB2A*1
CR353AB3A*1
CR353AB4A*1

30

180

150

120

40

2
3
4

CR353AC2A*1
CR353AC3A*1
CR353AC4A*1

40

240

200

160

50

2
3
4

CR353AD2B*1
CR353AD3B*1
CR353AD4B*1

tM

240V

an

CR353A

* Insert letter from Coil Selection Tables below.
information on 5-pole Forms, refer to your nearest GE Electrical Distribution
& Control sales office.

G) For

50Hz

60Hz

24 (2, 3-pole) 24
24
24
(4-pole)
110-120
110-120
208-240
208-240
277
416-480
416-480
550
575-600

A
B
F

c
D

DC Coil Selection Table®

68
87
87
87
-

87
87

60Hz

50 Hz

60Hz

50 Hz

7
10
10
10
10
10
10

7.4
12
12
12

2.3
4.0
4.0
4.0
4.0
4.0
4.0

2.7
4.6
4.6
4.6

-

12
12

5.61
3.9 4
89.5
366.0
713.0
1872.0
29 83.0

-

4.6
4.6

Resistance Ohms ±10%

Inrush VA
(Nominal)

Sealed VA
(Nominal)

Sealed Watts
(Nominal)

Inrush

Sealed

12-14 VDC
24-28 VDC
120 VDC

54
54
140

2.34
2.34
5.16

2.34
2.34
5.16

2.9 8
12.6
9 8.4

61.6
283.0
2783.0

tri

p

lec

R

Resistance
Ohms ±10%

Voltage

Letter Code
s

60
77
77
77
77
77
77

ca

H

H

50 Hz

lP

60Hz

Sealed Watts
(Nominal)

Sealed VA
(Nominal)

Inrush VA
(Nominal)

Voltage

Letter
Code

ar

AC Coil Selection Table

® Includes factory wired coil switch.

Factory Modifications

.E

Terminals:

Auxiliary Contacts:

Change letter in 9th position (CR353AC3AH1}

Add letter in 12th position (CR353AC3AH1B)

Binding Head Screw
With Quick Connect Terminals ...................... A
Without Quick Connect Terminals .
.
.
.C
Box Lug
With Quick Connect Terminals . .
.. . . .
. B
Without Quick Connect Terminals . .
.
.
. ..
D
.

.

.

.

.

w

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

None
10 Amp, 250 Vac SPDT® on left side . . . .
.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

Customer Part Number:

ww

No terminal markings
.
.
.
.
. . 00
Line ("L") markings at Top/Load ("T") markings at bottom .. 1
Load ("T") markings at Top/Line ("L") markings at bottom 2

0 Omit

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. .

.

.

.

.

.

.

.

.

.

..

.

.

A®

.

.B

600-volt rating, select a device with additional power pole.

Add letter in 13th position (CR353AC3AH1BB)

.

.

.

Change number in 1 1th position (CR353AC3AH1)
.

.

.

®Omit "A" if additional modification is not required.

® For

Terminal Markings:

.

.

.

Customer Part Number on device and carton label

.

.

.

.

.

.

.

.

B

.

"0" if additional modifications are not required.

5

.c
om

50- and 60-ampere, 2- and 3-pole

Open Type
Ampere Ratings

Inductive
Full Load

Locked Rotor

Standard
Open Type

Number
Of
Poles

Resistive
Per Pole

ua
ls

-

Catalog
Number

240V

480V

600V

50

300

250

200

62

2
3

CR353FE2B*1
CR353FE3B*1

60

360

300

240

75

2
3

CR353FF2B*1
CR353FF3B*1

an

CR353F

AC Coil Selection Table

A
B
F

c

D

60Hz

50Hz

60Hz

24
110-120
208-240
277
440-480
575-600

24
110-120
208-240

100
100
100
100
100
100

-

380-416
550

Voltage

p

s

CD Includes

factory wired coil switch.

Terminals:

60Hz

50Hz

60Hz

50Hz

11
11
11
11
11
11

14
14
14

8
8
8
8
8
8

9.4
9.4
9 .4

-

14
14

Inrush VA
(Nominal)

Sealed VA
(Nominal)

Sealed Watts
(Nominal)

110
110
110

3.8
3.8
3.8

3.8
3.8
3.8

lec

Factory Modifications

-

119
119

Sealed Watts
(Nominal)

-

9.4
9.4

Resistance Ohms

.E

.

Sealed

1.85

37.6
153.0
2519.0

5.2

133.0

.

.

.

.

.

.

.

.

.

None...............................
..A(j)
10 Amp, 250 Vac SPDT on left side .. . ..... . . .. .. . B
10 Amp, 600 Vac, 1-NO on left side . ....
. .... . ...G
.

.

(j) Omit "A"

.

.

.

.

.

.

.

.

if additional modification is not required.

.

Terminal Markings:

Customer Part Number:

Change number in 1 1th position (CR353FE3BH1)

Add letter in 13th position (CR353FE3BH1BB)

w

No terminal markings .. . . . . . . .. . . .. . . .. .... . ....
0®
Line ("L") markings at Top/ Load ("T") markings at bottom . 1
Load ("T") markings at Top/Line ("L") markings at bottom .2

ww

+ 10%

Inrush

Add letter in 12th position (CR353FE3BH1B)

Binding Head Screw
With Quick Connect Terminals . ....... . . . . . .. ..A
Without Quick Connect Terminals ..... .... . . .. . . ..C
Box Lug
With Quick Connect Terminals . . ....... . ... .... . .. B
Without Quick Connect Terminals ... . .... . . . . .......D

6

2.75
64.3
241.0
389.0
9 7 2.0
2074.0

Auxiliary Contacts:

Change letter in 9th position (CR353FE3BH1)

0 Omit

Resistance
Ohms ±10%

tri

12 VDC
24 VDC
115 VDC

R

119
119
119

ca

DC Coil Selection Table CD
Letter Code

50Hz

lP

H

Sealed VA
(Nominal)

Inrush VA
(Nominal)

Voltage

ar

Letter
Code

tM

* Insert letter from Coil Selection Tables below.

"0" if additional modifications are not required.

.

.

.

.

.

.

.

I

Customer Part Number on device and carton label

.

.

.

...

.

.

B

.c
om

75- and 90-ampere, 2- and 3-pole

Open Type

Ampere Ratings
Inductive
Full Load

Standard
Open Type

Number
Of
Poles

Resistive
Per Pole

Catalog
Number

240V

480V

600V

75

450

375

300

90

2
3

CR353EG2B*1
CR353EG3B*1

90

540

450

360

90

2
3

CR353EH2B*1
CR353EH3B*1

Insert letter from Coil Selection Tables below.

AC Coil Selection Table

D

110
220
-

440
550

Voltage

p

12 VDC
24 VDC
115 VDC

s

CD

263
263
-

263
263

50Hz

60Hz

50Hz

40
40
40
40
40
40

16
16
16
16
16
16

-

51
51
-

51
51

Resistance
Ohms ±10%
1.46
28.7
109 .0
169.0
547.0
655.0

-

19
19
-

19
19

Resistance Ohms ± 1 0%

Inrush VA
(Nominal)

Sealed VA
(Nominal)

Sealed Watts
(Nominal)

Inrush

Sealed

275
275
275

11.5
11.5
11.5

11.5
11.5
11.5

.54
2.13
47.1

12.7
51.9
1133.0

tri

R

60Hz

-

ca

DC Coil Selection TableCD
Letter Code

50Hz

233
233
233
233
233
233

-

lP

c

60Hz

50Hz

24
115-120
208-240
277
460
600

ar

60Hz
H
A
B
F

Sealed Watts
(Nominal)

Sealed VA
(Nominal)

Inrush VA
(Nominal)

Voltage

Letter
Code

tM

*

Locked Rotor

ua
ls

-

an

CR353E

Includes factory wired coil switch.

Terminals:

lec

Factory Modifications

Auxiliary Contacts:

Change letter in 9th position (CR353EG3BH1)
Binding Head Screw
With Quick Connect Terminals
Without Quick Connect Terminals
Box Lug
With Quick Connect Terminals
Without Quick Connect Terminals

.E

.

.

.

.

Add letter in 12th position (CR353EG3BH1B)
None
10 Amp, 250 Vac SPOT on left side
10 Amp, 600 Vac, 1-NO, 1-NC on left side
.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.
.

A
C
B
D

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. .

.

.

. .

.

.

Add letter in 13th position (CR353EG3BH1BB)

w

Customer Part Number:

Change number in 1 1th position (CR353EG3BH1)
.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

ww

(2) Omit "0" if additional modifications are not requ1red

.

.

.

.

.

.

.

.

.

.

.

.

.

.
.

.
.
.

0®

1
2

B

0

®Omit "A" if additional modification is not required.

Terminal Markings:

No terminal markings
Line ("L") markings at Top/Load ("T") markings at bottom
Load ("T") markings at Top/Line ("L") markings at bottom

A®

.

.

Customer Part Number on device and carton label

.

.

.

.

.

.

.

.

B

7

.c
om

120- and 150-ampere, 2- and 3-pole

Open Type

Ampere Ratings
Locked Rotor

Inductive
Full Load

*

Resistive
Per Pole

ua
ls

-

Standard
Open Type

Number
Of
Poles

Catalog
Number

240V

480V

600V

120

720

600

480

120

2
3

CR353GJ2A*1
CR353GJ3A*1

150CD

900

750

600

150

2
3

CR353GK2A* 1
CR353GK3A*1

an

CR353G

Insert letter from Coil Selection Table below.

CD For information on higher ratings, refer to your nearest GE Electrical Distribu­

tM

tion & Control sales office.

Voltage

D

60Hz

50Hz

115-120
230-2 40
460- 480
575-600

110
220
440
550

Factory Modifications

1150
1150
1150
1150

12 17
12 17
12 17
12 17

Change letter "A" in 9th position (CR353GJ2AB1)
Indicates Pressure Type Terminals

lec

l

Terminal Markings:

Change number "1" in 1 1th position (CR353GJ2AB1)

.E

Indicates Line ("L") markings at Top/Load ("T") markings at
bottom
Auxiliary Contacts:

Add letter in 12th position (CR353GJ3AB1B)
None . . ... . . . . . . . . . . . . . . . . . . . . . .. . . . .. .. . . . . . . . .. A2
10 Amp, 600 Vac, 1 NO . .. . . . . . . . .. . . . . . . . . . . . .. .. . .B
10 Amp, 600 Vac, 1 NC .............................C
10 Amp, 600 Vac, 1 N0 1 NC ........................ D

w

-

"A"

if additional modification is not required.

ww

®Omit

8

Sealed VA
(Nominal)
60/50Hz

150 Amp

tri

Terminals:

60/50Hz
120Amp

ca

A
8
c

Inrush VA
(Nominal)

120Amp

lP

Letter
Code

ar

AC Coil Selection Table

.

80
80
80
80

Sealed Watts
(Nominal)

Resistance
Ohms ±10%

60/50Hz

150Amp

120Amp

150Amp

120Amp

150Amp

85
85
85
85

1 8.4
1 8. 4
1 8.4
1 8.4

1 8.8
1 8. 8
1 8. 8
1 8. 8

2.11
10.6
41. 8
67.0

2.02
10. 4
41.7
6 4.4

Customer Part Number:

Add letter in 13th position (CR353GJ3AB 1 BB)
Customer Part Number on device and carton label . . . . . .. . B

.c
om

25-, 30-, and 40-ampere, Single- and Three-phase

Open Type

Ampere Ratings
Locked Rotor

25

480V

125

150

30

Poles

100

1
1
3
3

2
2
3
3

120

1
1
3
3

2
2
3
3

160

1
1
3
3

2
2
3
3

150

180

40

Phase

600V

200

240

-

1
-

1

With Ambient
Compensated
Overload Relay

Catalog Number

Catalog Number

1
1
3
3

CR354AB2A*3
CR354AB2A*3B
CR354AB3A*3
CR354AB3A*38

CR354AB2A*4
CR354AB2A*48
CR354AB3A*4
CR354AB3A*4B

-

1

1
1
3
3

CR354AC2A*3
CR354AC2A*38
CR354AC3A*3
CR354AC3A*3B

CR354AC2A*4
CR354AC2A*4B
CR354AC3A*4
CR354AC3A*4B

-

1

-

1

1
1
3
3

CR354AD28*3
CR354AD28*3B
CR354AD38*3
CR354AD38*38

CR354AD28*4
CR354AD28*4B
CR354AD38*4
CR354AD38*4B

-

1

lP

ar

* Insert letter from Coil Selection Table below.
CD Rated 10 Amp, 250 Vac.

With Standard
Overload Relay

OverLoad
Relays

an

240V

NO
Aux_
ContactCD

tM

Inductive
Full Load

ua
ls

CR354A - Open Type

Terminals:

tri

ca

25 and 30 Ampere Ratings have binding screw terminals.
40 Ampere Ratings have box lug type.

AC Coil Selection Table

H

Sealed VA
(Nominal)

Sealed Watts
(Nominal)

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

24
110-120
208-240
277
4 16-480

24
110- 120
208-240

60
77
77
77
77

68
87
87

7
10
10
10
10

7.4
12
12

2.3
4.0
4.0
4.0
4.0

2.7
4.6
4.6

--

4 16-480

-

87

-

12

-

4.6

Resistance
Ohms ± 10%
5.61
89.5
366.0
713.0
1872.0

.E

A
8
F
c

Inrush VA
(Nominal)

Voltage

lec

Letter
Code

Factory Modifications
Overload Relays:

w

Change letter in 1 1th position (CR354AC3AB3)

ww

Standard-Unwired
Ambient Compensated-Unwired
Standard-Wired
Ambient Compensated-Wired
.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

1
2
3

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

4

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

..

.

.

.

.

.

.

.

.

.

.

....

.

.

.

..

.

.

.

9

.c
om

50- and 60-ampere, Single- and Three-phase

ua
ls

CR354F - Open Type

Open Type

Ampere Ratings
Locked Rotor
240V

50

480V

250

300

60

360

Phase

Poles

200

1
1
3
3

2
2
3
3

240

1
1
3
3

2
2
3
3

600V

300

With Ambient
Compensated
Overload Relay

-

Catalog Number

Catalog Number

1
-

1
1
3
3

CR354FE2B*3
CR354FE28*3B
CR354FE38*3
CR354FE3B*3B

CR354FE28*4
CR354FE28*4B
CR354FE3B*4
CR354FE38*4B

1

-

1

1
1
3
3

CR354FF28*3
CR354FF28*3B
CR354FF3B*3
CR354FF38*3B

CR354FF28*4
CR354FF28*4B
CR354FF38*4
CR354FF38*4B

-

1

tM

* Insert letter from Coil Selection Table below.

With Standard
Overload Relay

OverLoad
Relays

NO
Aux.
Contact G)

an

Inductive
Full Load

lP

ar

G) Rated 10 Amp, 250 Vac.

Terminals:

tri

ca

50 Ampere ratings have box lug type.

AC Coil Selection Table

60Hz
24
110-120
208-240
277
440-480

Sealed VA
(Nominal)

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

24
110-120
208-240

100
100
100
100
100

119
119
119

11
11
11
11
11

14
14
14

8
8
8
8
8

9.4
9.4
9.4

--

380-4 16

-

1 19

Factory Modifications
Overload Relays:

w

Change number in 11th position (CA354FE3BB3)

ww

Standard-Unwired
. .
Ambient Compensated-Unwired
Standard-Wired
Ambient Compensated-Wired .

10

.

.

.

.

.

.

.

.

.

.

.

.

Sealed Watts
(Nominal)

50Hz

.E

H
A
B
F
c

Inrush VA
(Nominal)

Voltage

lec

Letter
Code

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

1
2
3

.. . ..

.

.

.

.

4

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

-

14

-

9.4

Resistance
Ohms ±10%
2.75
64.3
241.0
389.0
972.0

.c
om

25-, 30-, and 40-ampere, Two-speed Controllers

Standard
Open Type®

Number
Of
Poles

Locked Rotor

Inductive
Full Load

240V

480V

600V

25

150

125

100

2-3
3-3
5-3

CR355AB2A*1B
CR355AB3A*1B
CR355AB5A* 1B

30

180

150

120

2-3
3-3
5-3

CR355AC2A* 1B
CR355AC3A*1B
CR355AC5A*1B

40

240

200

160

2-3
3-3
5-3

CR355AD2B*1B
CR355AD3B*1B
CR355AD5B* 1B

Catalog
Number

tM

an

Ampere Ratings

ua
ls

- Open Type

CR355A

lP

ar

* Insert letter from Coil Selection Table below.
Note: Controllers shown are limited to 240 Vac coil rating. For controllers with
higher coil ratings, refer to the nearest GE Electrical Distribution & Control
sales office.
CD All 2-speed controllers include mechanical and electrical interlocking. For
control of 2-speed single-winding motors, use 5 3-pole or 2 3-pole and
separate 3-pole contactor.

AC Coil Selection Table

H
H

50Hz

Resistance
Ohms ± 1 0%

60Hz

50Hz

60Hz

50Hz

60Hz

50Hz

60
77
77
77

68
87
87
87

7
10
10
10

7.4
12
12
12

2.3
4.0
4.0
4.0

2.7
4.6
4.6
4.6

24 (2, 3-pole) 24
24
(5-pole)
24
110- 120
110- 120
208-240
208-240

.,

Sealed Watts
(Nominal)

5.61
3.94
89.5
366.0

tri

A
B

I

ca

60Hz

Sealed VA
(Nominal)

Inrush VA
(Nominal)

Voltage

Letter
Code

Terminals:

lec

Factory Modifications

Terminal Markings:

Change letter in 9th position (CR355AB2BH1B)
Binding Head Screw
With Quick Connect Terminals . .
Without Quick Connect Terminals
Box Lug
With Quick Connect Terminals .
.
Without Quick Connect Terminals .
.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

..

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

No terminal markings
0
Line ("L") markings at Top/Load ("T") markings at bottom ....1
.

.

.

.
.

.

A

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

. C

.
.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

B
D

ww

w

.E

.

Change number in 11th position (CR355AB2BH1B)

11

.c
om

50-, 60-, 75- and 90-ampere, Two-speed Controllers

Open Type

Ampere Ratings
Inductive
Full load

Locked Rotor

ua
ls

-

Standard
Open Type®

Number
Of
Poles

Catalog
Number

240V

480V

600V

50

300

250

200

2-3
3-3

CR355EE28*1C
CR355EE38*1C

60

360

300

240

2-3
3-3

CR355EF28*1C
CR355EF38*1C

75

450

375

300

2-3
3-3

CR355EG28*1C
CR355EG38*1C

90

540

450

360

2-3
3-3

CR355EH28*1C
CR355EH38*1C

an

CR355E

Q) All 2-speed controllers include mechanical and electrical interlocking. For

tM

* Insert letter from Coil Selection Tables below.
Note: Controllers shown are limited to 240 Vac coil rating. For controllers with
higher coil ratings, refer to the nearest GE Electrical Distribution & Control
sales office.

letter
Code

lP

AC Coil Selection Table
CR355E 50- and 60-ampere 2-speed Controllers

Inrush VA
(Nominal)

Voltage
50Hz

24
115-120
208-240

-

184
184
184

50Hz
-

208
208

Sealed VA
(Nominal)

60Hz

Sealed Watts
(Nominal)

50 Hz

32
32
32

-

41
41

60Hz

50Hz

12
12
12

14
14

-

Resistance
Ohms ±10%
1.46
28. 7
109.0

tri

110
220

60Hz

ca

60Hz
H
A
8

ar

control of 2-speed single-winding motors, use 2-3-pole form and a separate
3-pole contactor.

lec

AC Coil Selection Table
CR355E 75- and 90-ampere 2-speed Controllers
Voltage

letter
Code

60Hz

24
115-120
208-240

50Hz
-

110
220

.E

H
A
8

Terminals:

Indicates box lug type terminals.

ww

I

w

Letter "B" in 9th position (CR355EE2B11C)

12

Sealed VA
(Nominal)

Inrush VA
(Nominal)

60Hz
233
233
233

50Hz
-

263
263

60Hz
40
40
40

Sealed Watts
(Nominal)

50Hz
-

51
51

60Hz

50Hz

16
16
16

19
19

-

Resistance
Ohms ± lOo/o
1.02
25.2
95.6

.c
om

Technical Data

CR
353

CR
354

CR
355

Induetive

Resistive

AB

AB

AB

25

AC
AD

AC
AD

AC
AD

30
40

35
40

CA

20
25

CB

cc

240V

480V

600V

240V

125
150

100
120

150
180

50

150
180
240

200

160

30

120

100

80

35

150

125

100

480V

Part Winding

600V

240

125 CD
150 CD
2oo CD

10o CD
120 CD
160 CD

120 CD

10o CD

8o CD

100

60

40

150 CD

70
125 CD

100 CD

150 CD

75
125 CD

100 CD

125
150

45

240V

480V

150

125

100

180

150
192

120

192

-

600V

160

-

-

50

-

-

150

120

EE

50

62

300

250

200

-

-

-

300

250

200

EF

60

75

360

300

240

-

-

-

360

-

-

EG
EH

75
90

90
90

450
540

375
450

300

-

-

-

360

-

-

-

450
540'

375
450

300
360

62

300

250

200

-

75

360

300

240

-

GJ
GK

120
150

120
150

720
900

600
750

600

480

tM

180

60

-

-

300

250

200

-

-

360

300

240

600
750

480
600

-

-

-

-

-

-

ca

CD These ratings apply where the contactor is not required to make and break line
® 24 Volt coils 2- and 3-pole forms pickup at 75% or less of nominal coil voltage.
® For box lug and pressure type terminals.

720
900

AB
AC
AD

CR
355
AB
AC
AD

�

CA
CB

cc

EG
EH
FE
FF

ww

GJ
GK

FE
FF

8-16
8-16
4-14

35 lb.-in.

8-16

50% or less of

nominal

nominal

coil voltage

coil voltage

85% or less of

55% or less of

8-16

2-14

nominal

nominal

coil voltage

coil voltage

85% or less of
nominal
coil voltage

55% or less of
nominal
coil voltage

110-14
1/0-14

85% or less of
nominal

60% or less of
nominal

2-14

coil voltage

coil voltage

85% or less of
nominal

65% or less of
nominal

coil voltage

coil voltage

Family CR

Vol.

Section

Issued

File

Guide

Class

2
2
2

52
51
21

09/26/74
09/25/74
02/09/67

LR15492
LR15492
LR15492

361-E-0.2
361-E-0.2
361-E-0.2

1222 01
1222 01
1222 01

E1811
E1811
E1811

2
2
2

50
50
50

08/09/75
08/09/75
08/09/75

LR15492
LR15492
LR15492

361-E-0.2
361-E-0.2
361-E-0.2

1222 01
1222 01
1222 01

E1811
E1811
E1811

2
2
2

76
76
76

02/08/80
02/08/80
02/08/80

LR15492
LR15492
LR15492

361-E-0.2
361-E-0.2
361-E-0.2

1222 01
1222 01
1222 01

EE
EF

E1811
E1811

2
2

26
25

03/10/70
01/22/70

LR15492
LR15492

361-E-0.2
361-E-0.2

1222 01
1222 01

EG
EH

E1811
E1811

2
2

24
30

10/15/68
06/01/74

LR15492
LR15492

361-E-0.2
361-E-0.2

1222 01
1222 01

E1811
E1811

2
2

54
54

06/17/75
06/17/75

LR15492
LR15492

361-E-0.2
361-E-0.2

1222 01
1222 01

E1811
E1811

3
3

6
5

10/15/68
05/26/76

LR15492
LR15492

361-E-0.2
361-E-0.2

1222 01
1222 01

w

I

CSA Reference

File

.E

AB
AC
AD

coil voltage

Terminal
Torque®

2-14

2-14

2/0-10
3/0-8

35 lb.-in.

80 lb.-in.

50 lb.-in.

50 lb.-in.

200 lb.-in.

Shipping Weights

E1811
E1811
E1811

lec

I

CR
354

tri

Underwriters Laboratories
Reference

Family

50% or less of
nominal

Wire
Size
Range
AWG

connection if the unit recycles under stalled rotor conditions.

Underwriters Laboratories and CSA References
CR
353

nominal
coil voltage

85% or less of

40

50

85% ® or less of

-

30

FE
FF

Dropout Volts

Pickup Volts

ar

FF

3 Ph-2-pole
1 Ph-1-pole

3 Ph-3-pole
1 Ph-2-pole

lP

EG
EH

FE

Locked Rotor Ampere Ratings

Amperes

an

Family

ua
ls

Definite Purpose Control Technical Data

353AB, AC,
354AB, AC,
355AB, AC,
353CA, CB,
355EE, EF
353EG, EH
355EG, EH
353FE, FF
354FE
353GJ, GK

AD
AD
AD
CC

Estimated
Shipping Weight
(Lbs.)
1.5
3.0
4.3
1.0
8.1
4.0
8.1
1.9
3.5
17.5

13

.c
om

Heater Selection Information

a motor of larger rating than the maximum given on the
nameplate for the starter.

ua
ls

Heater Selection for StartersCD
Single-phase (25-, 30-, 40-, 50-, and GO-ampere)

To prevent overloading the starter do not select heater(s) for

(Heater amps based on 75°C wire)
All heaters are packaged three to a carton.

For continuous rated motors, with a service factor of 1.15 to
1.25, select the heater with maximum motor amperes equal to

Single-phase (1 Heater Required)

or immediately greater than the motor full·load current (pro·

Maximum Motor Full Load Amperes

vides a maximum of 125 percent protection). For continuous
rated motors with no service factor, multiply the full·load cur·

25 Amp
Starter

heater.
To protect the heater and starter during a short circuit, pro·
vide motor·branch·circuit protection in accordance with Table
430-152 in Article 430 of the National Electrical Code. In no
case should the fuse rating exceed 4 times the motor full·load

If full·load amperes of motor falls between two ratings, select
These tables are not to be used to select heaters for Hermetic
Motor applications. Contact your nearest GE sales office for

ww

w

.E

lec

tri

ca

lP

information.

14

Heater Cat. No.
CR123

5.79
6.12
6.49

6.15
6.47
6.84

6.15
6.47
6.84

C592A
C630A
C695A

7.59
8.71
9.19

7.59
8.71
9.19

7.59
8.71
9.19

7.72
8.99
9.87

7.72
8.99
9.87

C778A
C867A
C955A

10.1
11.2
11.9

10.1
11.2
11.9

10.6
12.0
12.3

10.6
12.0
12.3

C1048
C113B
C125B

12.6
14.5
17.7

12.6
14.5
17.7

12.6
14.5
17.7

14.0
15.7
17.6

14.0
15.7
17.6

C137B
C151B
C163B

19.1
21.4
22.9

19.1
21.4
22.9

19.1
21.4
22.9

20.1
23.3
27.0

20.1
23.3
27.0

C180B
C198B
C214B

24.7
25.0

24.7
25.9
27.1

24.7
25.9
27.1

29.8
32.2
33.9

29.8
32.2
33.9

C228B
C250B
C273B

30.0

30.2
34.8
40.0

36.7
42.5
46.2

36.7
42.5
46.2

C303B
C330B
C366B

50.0

50.3
52.4
58.2
60.0

C400B
C440B
C460B
C500B

ar

heaters for the higher rating.

60 Amp
Starter

5.79
6.12
6.49

tM

Fuse Rating.

50 Amp
Starter

5.79
6.12
6.49

10.1
11.2
11.9

current for single·element fuses, or 2.25 times for dual·element
fuses, or the fuse size listed in heater table under Maximum

40 Amp
Starter

an

rent of the motor by 0.90 and use this value to select the

30 Amp
Starter

---

-----

---

---

---

---

---

---

---

---

---

---

-

--

-

---

---

---

---

---

---

--

CD Heater selection table applies to Open & Type

1

enclosed starters with

standard or ambient compensated overload relays.

.c
om

Heater Selection Information (Continued)

Heater Selection for StartersCD
Three-phase (40-, 50-, and 60-ampere)

(Heater amps based on 75°C wire)

(Heater amps based on 75°C wire)

All heaters are packaged three to a carton.

All heaters are packaged three to a carton.

3-phase (3 Heaters Required)

3-phase (3 Heaters Required)

Heater Cat. No.

Maximum Motor Full Load Amperes

ua
ls

Heater Selection for StartersCD
Three-phase (25- and 30-ampere)

Maximum Motor Full Load Amperes

Heater Cat. No.
CR123

30 Amp Starter

CR123

40 Amp Starter

50 Amp Starter

5.00
5.53
6.02

5.00
5.53
6.02

C630A
C695A
C778A

5.72
6.30
7.04

6.07
6.63
7.35

5.14
5.63
6.26

C630A
C695A
C778A

6.93
7.30
7.98

6.93
7.30
7.98

C867A
C955A
C 104B

8.09
8.89
9.78

7.15
7.58
8.39

C867A
C955A
C 104B

8.77
9.40
10.6

8.77
9.40
10.6

C 1 13B
C 125B
C 137B

1 1.6
14.0
15.4

1 1.6
14.0
15.4

C 15 1B
C 163B
C 180B

17.0
18.9
20.3

17.0
18.9
20.3

C 198B
C2 14B
C228B

2 1.5
23.0
25.0

2 1.5
23.0
25.4

C250B
C273B
C303B

---

7.91
8.80
9.27

10.8
1 1.8
13.0

9. 1 1
9.67
1 1.0

C 1 13B
C 125B
C 137B

13. 1
15.5
16.8

14.5
16. 1
17.9

12.0
14.4
16.3

C 15 1B
C 163B
C 180B

18.0
19.7
2 1.6

19.8
22.0
24.4

17.3
19.3
20.9

C 198B
C2 14B
C228B

23.9
25.5
28.2

27.1
29.9
34. 1

22.9
24.7
28.0

C250B
C273B
C303B

31.5
34.7
37.8

38.8
44.3
50.0

32. 1
35.9
4 1.5

C330B
C366B
C400B

40.0

---

43.4
46.4
50.9

C440B
C460B
C500B

56.9
60.0

C550B
C600B

tM

C330B
C366B

28. 1
30.0

(i) Heater selection table applies to Open and Type

---

--

--

---

---

--

---

---

(i) Heater selection table applies to Open and Type

1 enclosed starters
with standard or ambient compensated overload relays.

ww

w

.E

lec

tri

ca

1 enclosed starters
with standard or ambient compensated overload relays.

60 Amp Starter

9.99
1 1. 1
12. 1

ar

lP

---

an

25 Amp Starter

15

.c
om

Field Installation Kits
(Not available for CR353C compact design)

Kit Catalog
Number

25-60 Amp
75-90 Amp
120-150 Amp

SPOT
SPOT
1 NO
1 NC
1 N0-1 NC

CR353XAAA
CR353XAAB
CR353XABC
CR353XACC
CR353XADC

H
H
A
B
F
c

Enclosure Kits (Type 1)
Kit Catalog
Number

25-60 Amp
75-90 Amp
120-150 Amp

CR353XE1BB
CR353XE1BC
®

20-50 Amp

CR353XE1AA

-- --

- ---

to nearest GE Ee
l ctrical Distribution

&

Control sales office.

H
A
B
F
c

ca
Catalog Number

CR353AB, AC, AD
CR354AB, AC, AD
CR355AB, AC, AD

.E
lec

tri

CR353XY1
(Package of 10)

H
A
B
F
c

A
B
c
D

A
B
c
D

Kit
Catalog Number

25
30

1
1

55-152313G223
55-152313G071

40
40
50®
600
75
90

3
4
1
1
1
1

55-152313G111A
55-152313G111B
55-152313G216
55-152313G237
55-152313G218
55-152313G217

Box lug with
quick connects

w

3
3

55-152313G139
55-152313G140

Pressure type

353AD
353AD
353FE
353FF
353EG
353EH
353GJ
353GK

CIJ

120
150

ww

®For CR355EE, use 55-152313G150
For CR355EF, use 55-152313G277

-

380-416

55-B23H
55-B23A
55-B23B
55-B23F
55-B23C

24
115-120
208-240
277
440-480

24
110
220
-

440

55-B21H
55-B21A
55-B21B
55-B21F
55-B21C

}

24
115-120
208-240
277
460

-

110
220
-

440

55-B22H
55-B22A
55-B22B
55-B22F
55-B22C

115-120
230-240
460-480
575-600

110
220
440
550

55-501336G002
55-501336G003
55-501336G004
55-501336G005

110
220
440
550

55-501463G002
55-501463G003
55-501463G004
55-501463G005

150-amp-CR353GK

Number
Of Poles
Per Kit

353AB
353AC

Contactor
Rating
Amperes

24
110-120
208-240

120-amp-CR353GJ

Replacement Contact Kits
Family
CR:

24
115-120
208-240
277
440-480

75-, 90-amp-CR353EG, EH, CR355EG, EH

Double .250" Quick Connect Adapter
For Coil Terminals
For Use On:

55-B19H
55-B20H
55-B20A
55-B20B
55-B20F
55-B20C

50-, 60-amp-CR355EE, EF

lP

® Refer

-

24
24
(2-, 3-pole)
24
24
(4-pole)
110-120
110-120
208-240
208-240
277
416-480
416-480
-

ar

Starter
Rating

Catalog
Number

50- 60-amp-CR353FE, FF, 354FE

H
A
B
F
c

Kit Catalog
Number

50hz

60Hz

25-, 30-, 40-amp-CR353AB, AC, AD, 354AB, AC, AD, 355AB, AC, AD

Auxiliary contacts for 25- through 90-ampere contactors are rated 10 amp,
250 Vac, '13 Hp@ 125 Vac or 250 Vac. Auxiliary contacts for 120- and 150ampere contactors are rated 7200 VA make, 720 VA break, 10 Amp carry,
600 Vac.

Contactor
Rating

Coil Ratings Volts

Letter
Code

an

Auxiliary CD
Contact Type

tM

CD

Contactor
Rating

ua
ls

AC Replacement Coils

Auxiliary Contact Kits For Field Installation

Type Of
Termination
Binding screw with
quick connects

115-120
230-240
460-480
575-600

Inches
Millimeters

"' Est'1mat'mg 0n1y
ror

CR353C - 20-, 25-, and 30-ampere Contactors (Compact Design)

3.31

-

84.1

p

-

J

ar

���
r----- ��

79.5

2.16
54.9

-

MOUNTING HOLES
FOR #10 SCREWS
(4 PLACES)

2.00
50.8

ca

lP

66.7

3.13

tM

M

1\

1

ua
ls

b

tiD
r1

an

rI

1HD

.c
om

.
.
D uaI D 1mens1ons

Contactor Dimensions

tri

CR353A and F - 25- Through 60-ampere Contactors

.4 1
10.3

3.12

lec

79.4

3.25
82.5

.E

3.75

�r

w

-

"C"

.47
1 1.9

_______..,
Number

c

Catalog Number

25-, 30-, 40-amp

CR353AB, AC, AD

2, 3

--

--

--

--

95.3

61.5

83.3

17.5

25-, 30-, 40-amp

CR353AB, AC, AD

4

--

--

--

95.3

78.6

83.3

50-, 60-amp

CR353FE, FF

2, 3

--

--

--

--

95.3

69.8

90.4

12.7

ww

Rating

Of Poles

A
3.75

3.75

3.75

B
2.42

3.09

2.75

3.28

3.28

3.56

D
.69

MOUNTING HOLES FOR
SCREWS (6 PLACES)

#10

.22

--

5.6
.50

17

.

Inches
Millimeters

.c
om

Dua I o·1mens1ons

Contactor Dimensions (Continued)

.
.
F,or Est1matmg 0nIy

ua
ls

CR353E - 75- and 90-ampere Contactors

,I
n
'L
---::r.-=--p "
I
r

,o

I I
I 1'=1

::

,,

an

1
I

II'

I�.\

,
--4L r-r1
_J_
0•

4.28
108.7

�I

.59
15.1

ar

-

-

MOUNTING HOLES FOR
# 10 SCREWS (3 PLACES)

tri

ca

CR353G - 120- and 150-ampere Contactors

10-:
f---"1

I
I

I

I
I

I
I

I

lec

.E

8.8 1

I

I

I

i

r--...J

L.��

7.75

t

196.8

ww

w

2 15.9

4.36
1 17.5

lP

L___
r·

4.44
1 12.7

tM

ll.J

5.00
127.0

%" SCREWS (3 PLACES)
MOUNTING HOLES FOR

38.1

4.50
114.3

Inches

DuaI D.1mens1ons

Millimeters

.c
om

.

Starter Dimensions

c Esr·tma r·mg 0nIy
,-or

CR354A - 25-, 30-, and 40-ampere Starters

.,.. �
�1

ua
ls

3.44

------1

MOUNTING HOLES FOR
#10 SCREWS (3 PLACES)

CR354F - 50-ampere Starters

ca

lP

3.75
95.3

ar

tM

an

7.13
181.1

, , -----l
�1

9.7
.38

lec

tri

3.62

6.50
165.1

ww

w

.E

7.13
181.1

t

----- 3.63
92.2

..,

___

.25
6.4
M OUNTING H OLES F OR
#10 SCREWS (3 PLACES)

19

.

.c
om

DuaI D.1mens1ons

Two-speed Controller Dimensions

Inches
Est.1ma t.mg 0n1y
,-or
c::
Millimeters

CR355A - 25-, 30-, and 40-ampere (5-3-pole)

.25

ua
ls

64

3.75

3.25
82.6

tM

an

95.3

3.50

MOUNTING HOLES FOR
# 10 SCREWS

ca

lP

ar

88.9

lec

tri

CR355A - 25-, 30-, and 40-ampere (2-3 and 3-3-pole)

3.75

.E

95.3

3.28

ww

w

83.3

20

j

MOUNTING HOLES FOR
# 10 SCREWS

DuaI D.1mens1ons

Inches
c E.sr·1ma r·mg OnIy
ror
Millimeters

CR355E - 50-, 60-, 75-, and 90-ampere

8.38
212.9

an

ua
ls

.60
15.2

.c
om

.

Two-speed Controller Dimensions

tM

5.00
127.0

MOUNTING HOLES FOR
#10 SCREWS (3 PLACES)

ww

w

.E
lec

tri

ca

lP

ar

3.38 ----+---85.7

21

Inches
Millimeters

ror
� Esr·1mar·mg OnIy

For CR353A & F, 25-, Through 60-ampere Contactors;
And CR354A & F, 25- Through 50-ampere Starters

�

ua
ls

1.63

-:32

3.00
76.2

.13

1r
10.00
254.0

"B''

an

1

41.3

6.00
152.4

.c
om

.
D uaI D.1mens1ons

Enclosure Dimensions

(TOP

&

(TOP

&

"A "
BOTIOM)

tM

(BOTH S IDES)

1.00
25.4

ca

lP

"A" Combination Knock-outs For 3.4" or 1" Conduit
"8" Combination Knock-outs For ¥2" or 3.4" Conduit

ar

RESET BUTION IN
STARTER ENCLOS URE

3 POINT MTG
FOR #10 SCR EWS

For CR353E, 75- and 90-ampere Contactors

41.3

lec

3.69
93.7

tri

1.63

7.38
187.3

.E

13.25
336.6

ww

w

/

3 POINTMTG
FOR 1!4' SCREWS

''A'' Combination Knock-outs For 1 " or 1 Y4" Conduit
"8" Combination Knock-outs For ¥2" or 3/4" Conduit

22

-:32
.13

"B"

(BOTH SIDES)

"

&

"B"

(TOP

BOTIOM)

A"

BOTIOM)

.E
lec
w

ww

ua
ls

PUSH BUTTONS

GE's heavy-duty oiltight
series of octagonal ring push
buttons are designed for
worldwide acceptability in an
attractive, rugged design.
They even provide watertight
and dust-tight protection
without the use of cumber­
some operator boots. With
their single-screw contact
block mounting arrangement
you can cut installation time
and costs. And their clear
LEXAN covers make contact
inspection easy, too.

tM

GE's 300-Line offers NEMA­
rated controls with a com­
plete line of full-voltage non­
reversing, reversing, two­
speed, and combination con­
tactors and motor starters.
They're specification approv­
ed for the toughest industrial
applications.

an

NEMA-RATED
MOTOR CONTROLS

tri

GE's worldwide distributors
also offer the logical choice
for equipment users, too,
with a full line of NEMA and
IEC rated devices for
replacement or updating
existing equipment. No
matter what control you're
presently using you never
need to worry about
availability of the right control
components. Your local GE
distributor is fully stocked to
efficiently handle all your
replacement part needs.

GE's internationally accepted
400-Une contactors give you
control in 10 ratings from 5
to 50 horsepower in a
modular economical design.
The complete 400-Line in­
cludes contactors, overload
relays and accessories for
machine tool and other in­
dustrial applications.

GE's full line of sensors
includes mechanical limit
switches, proximity switches,
and photoelectric controls to
meet a wide variety of in­
dustrial applications; in­
cluding metal working,
automotive, and material
handling. They're available in
modular plug-in forms, com­
pact threaded-barrel forms,
and can sense virtually any
material with great speed
and accuracy.

ar

and Europe can rely on a
single source to meet their
customer's control specifica­
tions. Both NEMA and IEC
rated components are now
available worldwide from one
reliable supplier-GE. Now
to help you fill orders fast
you can get quick delivery
on the exact control you
need. You can also count on
the complete local suport
you need for special design
and application assistance so
you can better fill your
customer's needs.

SENSORS

lEe-RATED
MOTOR CONTROLS

lP

original equipment
manufacturers in the U.S.

Now,

.c
om

Products For All Your

ca

Quality

full

ponents •nr,.. ...-.....
through twe11V&-DOI& Qt)ru\'t:
figu rations

up to 600

latched, seii'-Cht�iit'IQ . atl
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2011:09:07 11:29:39-04:00
Creator                         : FUJITSU fi-6670dj + sipc
Modify Date                     : 2011:09:07 18:56:37-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2011:09:07 18:56:37-04:00
Creator Tool                    : FUJITSU fi-6670dj + sipc
Format                          : application/pdf
Document ID                     : uuid:da894274-c04e-48e1-9945-7521d08159df
Instance ID                     : uuid:e36318e7-a863-4f74-9a9d-6f91ba7c8dbe
Producer                        : Adobe Acrobat 10.0 Paper Capture Plug-in with ClearScan
Page Count                      : 24
EXIF Metadata provided by EXIF.tools

Navigation menu