Product Detail Manual
2014-09-05
: Pdf 566569-Attachment 566569-Attachment 783585 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 9
Occupancy and
Vacancy Sensors for an
Energy Conscious World
H-MOSS®
Hubbell Motion Sensing Switches
Adaptive Technology • Dual Technology
Ultrasonic • Passive Infrared
2 3
Adaptive Technology is a Hubbell patented
innovation that delivers benefits to both building
owners and occupants. The building owner achieves
reduced energy costs, fewer adjustments and less
maintenance while the building occupant experiences
fewer false on and offs and disturbances.
Adaptive Technology occupancy sensors use
microprocessors that make all the decisions for setting
adjustments. Internal software constantly monitors
the controlled area and automatically adjusts the
sensitivity and timer based on environmental history.
This means that instead of manually adjusting the
sensor for seasonal changes, modified airflow,
furniture layout or occupancy pattern changes, the
sensor automatically adjusts itself. These automatic
adjustments eliminate the need for multiple manual
adjustments by maintenance personnel or outside
contractors. Hubbell offers Adaptive Technology
throughout its product offering—wall switches, ceiling
and wall mount sensors—in conjunction with dual
technology, ultrasonic and passive infrared products.
Adaptive Technology...
Smart Technology for Today’s Needs
Benefits:
• “Install-and-forget”operation
• Adaptstospaceandneeds
•Seasons
•Airflow
•OccupancyPatterns
• Reducesfalseonandoffs
HowtoSelecttheRightTechnology
fortheProperApplication
Passiveinfrared(PIR)technologysensesoccupancybydetectingthemovementofheat
emittedfromthehumanbodyagainstthebackgroundspace.UnlikeUStechnology,PIR
sensorsrequireanunobstructedline-of-sightfordetection.Thesesensorsuseasegmented
lens, which divides the coverage area into zones. Movement between zones is then interpreted
asoccupancy.PIRsensorsareidealfordetectingmajormotion(e.g.walking),andtheywork
best in small, enclosed spaces with high levels of occupant movement.
Benefits:
• Longrangedetection
• Reliabletriggering
• Costefficient
Passive Infrared
(PIR)
Ultrasonic(US)technologysensesoccupancybybouncingsoundwaves(32kHz-45
kHz)offofobjectsanddetectingafrequencyshiftbetweentheemittedandreflectedsound
waves. Movement by a person or object within a space causes a shift in frequency, which the
sensor interprets as occupancy. While US occupancy sensors have a limited range, they are
excellent at detecting even minor motion such as typing and filing, and they do not require an
unobstructedline-of-sight.ThismakesUStechnologysensorsidealforanapplicationlikean
office with cubicles or a restroom with stalls.
Benefits:
• Detectsmallmotion
• Seesaroundobstructions
• Costefficient
Ultrasonic (US)
Dualtechnologyoccupancysensorscombinebothpassiveinfrared(PIR)andultrasonic(US)
technologiesformaximumreliability.BecauseUSandPIRneedtobothdetectoccupancyto
turn lighting on, dual technology sensors minimize the risk of lights coming on when the space
isunoccupied—falsetriggering.Continueddetectionbyonlyonetechnologythenkeepslighting
onasnecessary.Dualtechnologysensorsofferthebestperformanceformostapplications.
Benefits:
• Trackoccupancyonwithtwosensingmethods
• Minimizesfalsetriggering
• Consistent,reliableoperation
Dual Technology
Location Passive
Infrared (PIR) Ultrasonic Dual
Technology Sensor Style
Bedroom
Cafeteria
Closet
ConferenceRoom
Classroom
LectureHall
Library
Hallway
RestRoom(multi-stall)
PrivateOffice
Storage
Lobby
Warehouse
10% 20% 30% 40% 50% 60% 70% 80% 90%
Source: Esource
Energy Savings
Percentage Range
Private Office
Open Office
Classroom
Conference Room
Restroom
Storage Room
Highbay
Sensor
4 5
Energy Savings with Occupancy Sensors
Hubbell Occupancy Sensors Play a Key Role
Usingadvancedtechnology,Hubbell’sH-Moss®OccupancySensorsaredoingtheirparttosaveenergy
and provide sustainability by automatically and effectively turning lights on when a room is occupied
andoffwhenaroomisvacant.Inatypicalofficebuilding,wherelightingaccountsfor35to45%of
energyuse,H-Moss®OccupancySensorshavethepotentialtoreducewastedlightingby13to90%fora
significantreturnoninvestment(ROI).
Hubbell offers a broad range of occupancy and vacancy sensors and lighting controls that meet the latest
codesandstandards,includingASHRAE/IESNA90.1andCEC’sTitle24.H-Moss® OccupancySensors
canalsoprovideLEED®pointsincategorieslikeSustainableSites,EnergyandAtmosphere,Indoor
EnvironmentalQualityandInnovativeDesignProcess.
Typical Applications
Applicationsaregeneralized.Consult
your Hubbell representative for the type
of technology and products that fit your
needs.
Wall
Switch Ceiling
Sensor Wall
Sensor
Potential Energy Savings Using Occupancy Sensors
Reduce Energy
Reduce Energy Consumption
and Meet Federal and State
Standards and Guidelines
Reductionofenergyconsumptionatalllevels:
local, state and national is critical. Today’s
buildings,bothcommercialandresidential-
newandrenovated-mustfollownewstateand
federal standards and codes which call for energy
efficiency throughout a facility.
LEED
LEED(LeadershipinEnergyandEnvironmental
Design)whichissponsoredbytheCanada
GreenBuildingCouncil(CaGBC)hascreateda
rating system to define what constitutes a green
building by establishing common standards of
measurement, and promoting integrated and whole
building design. This certification applies to both
newandrenovatedcommercialbuildings.Points
are awarded by category and there are four levels
ofcertification-certified,silver,goldandplatinum.
SustainableSites-SS
Lightpollutionreduction
EnergyandAtmosphere-EA
Optimizeenergyperformance
IndoorEnvironmentQuality-EQ
Controllabilityofsystems,lighting
Innovation&DesignProcess-ID
Innovation in design
H-MOSS, Hubbell Motion Sensor Switches
offer a large array of occupancy sensors,
which can be utilized to help increase energy
efficiencyinthefollowingcategories:
LEED Credit Categories
28'
28'
24'
29'
26'
21'
50'
Ultrasonic Major Motion
Ultrasonic Minor Motion
Passive Infrared
Note: Ultrasonic output is 40kHz
14.5'
14.5'
24'
26' 21'
Ultrasonic Major Motion
Ultrasonic Minor Motion
20
10
0
300 10 20 30 40 50
7'
7'
Top View
Side View
28'
28'
50'
Passive Infrared
32'
40'
23'
20'
32'
23'
Ultrasonic Major Motion
Ultrasonic Minor Motion
Passive Infrared
ATD1600WRP, ATD1600W ATP1600WRP, ATP1600W
40'
20'
(ATP120HBRP,ATP12HB)
6 7
H-MOSS® Wall Switches
Featuring Adaptive Technology
AD1277W1
AU1277W1
AD1277W2
AU1277W2
Adaptive Technology, Dual (Ultrasonic and Passive Infrared)
1000 sq. ft. coverage with photocell, 800W Incandescent,
1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC,
3470W Fluorescent at 347V AC
Circuit Button Colour 120/277V
Catalogue Numbers 347V
Catalogue Numbers
Single 1Buttonformanual/auto
control Ivory
White AD1277I1
AD1277W1 AD347I1
AD347W1
Single Auto control with no button Ivory
White AD1277I1N
AD1277W1N AD347I1N
AD347W1N
Dual 2Buttonsformanual/auto
control Ivory
White AD1277I2
AD1277W2 AD347I2
AD347W2
Dual Auto control with no button Ivory
White AD1277I2N
AD1277W2N AD347I2N
AD347W2N
Sensorsareavailableinthreespecialordercolours.Toorderspecialordercolours,replace“IorW”withthefollowing:LA
(LightAlmond),GY(Gray)orBK(Black).
Adaptive Technology, Ultrasonic
400 sq. ft. coverage with photocell,
800W Incandescent, 1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC,
3470W Fluorescent at 347V AC
Circuit Button Colour 120/277V
Catalogue Numbers 347V
Catalogue Numbers
Single 1Buttonformanual/auto
control Ivory
White AU1277I1
AU1277W1 AU347I1
AU347W1
Single Auto control with no button Ivory
White AU1277I1N
AU1277W1N AU347I1N
AU347W1N
Dual 2Buttonsformanual/auto
control Ivory
White AU1277I2
AU1277W2 AU347I2
AU347W2
Dual Auto control with no button Ivory
White AU1277I2N
AU1277W2N AU347I2N
AU347W2N
• Adaptivetechnology-“Installandforget”
operation
• All digital sensing technology
• Dual120/277VACoperation50/60Hz
• Autoormanual“On”operatingmodes
• No minimum load requirements
• Hardlens(dualtechnology,passiveinfrared)
• Zero arc point switching
• Built in photocell with manual super saver
mode for daylight harvesting
• Two relays for two level switching or dual load
control(AD,APAU1277x2,2Nseries)
• C-ULUS
AllH-MOSSWallSwitcheswithAdaptiveTechnologyfeaturedbelowhavethe
followingstandardfeatures:
AU1277W1N
AU1277W2N
AD1277W1N
AD1277W2N
Note: Ultrasonic output is 40kHz
Sensors are available in three special order colours.
Toorderspecialordercolours,replace“IorW”
withthefollowing:
LA(LightAlmond),GY(Gray)orBK(Black).
Wallplates are sold separately.
H-MOSS® Wall Switches and Wall Mount
Sensors Featuring Adaptive Technology
AP1277W1
AP1277W2
Adaptive Technology Wall Mount Sensors
Dual (Ultrasonic and Passive Infrared)
Description Coverage Colour Catalogue Numbers
32kHz, with photocell and isolated relay 1600sq.ft. White ATD1600WRP
32kHz 1600sq.ft. White ATD1600W
Passive Infrared
Description Coverage Colour Catalogue Numbers
With photocell and isolated relay 1600sq.ft. White ATP1600WRP
1600sq.ft. White ATP1600W
For aisle and high bay applications,
with photocell and isolated relay 120linearft. White ATP120HBRP
For aisle and high bay applications 120linearft. White ATP120HB
Note: All wall mount sensors must use a CU series control unit. See page 11 for details.
ATD1600WRP
ATD1600W
ATP1600WRP
ATP1600W
ATP120HBRP
ATP120HB
• AdaptiveTechnology-“Installandforget”
operation
• Swivel mounting bracket included for wall
or ceiling mounting
• All digital sensing technology
• Photocellfordaylightharvestingandrelay
interface with auxiliary systems such as
HVAC(WRPandHBRPmodels)
• 24VDC,33mA
AP1277W1N
AP1277W2N
Adaptive Technology, Passive Infrared
1000 sq. ft. coverage with photocell, 800W Incandescent,
1000W Fluorescent at 120V AC, 1800W Fluorescent at 277V AC,
3470W Fluorescent at 347V AC
Circuit Button Colour 120/277V Catalogue
Numbers 347V
Catalogue Numbers
Single 1Buttonformanual/auto
control Ivory
White AP1277I1
AP1277W1 AP347I1
AP347W1
Single Auto control with no button Ivory
White AP1277I1N
AP1277W1N AP347I1N
AP347W1N
Dual 2Buttonsformanual/auto
control Ivory
White AP1277I2
AP1277W2 AP347I2
AP347W2
Dual Auto control with no button Ivory
White AP1277I2N
AP1277W2N AP347I2N
AP347W2N
Sensors are available in three special order
colours. To order special order colours, replace
“IorW”withthefollowing:LA(LightAlmond),
GY(Gray)orBK(Black).Wallplatesaresold
separately.
Adaptive Technology, Passive Infrared
36'
36'
36'
16'
16'
40'
16'
16'
40'
Passive Infrared
16'
16'
40'
Passive Infrared
16'
16'
35'
3.5º
3.5º
10'
(3.0m)
Mounting Height
42" to 54"
(106.7 to 137.2cm)
20'
(6.1m)
See Horizontal
View for Range
14.5"
(36.8cm)
29"
(73.3cm)
16'
16'
40'
Passive Infrared
89
Description Coverage 120V AC 277V AC Colour Catalogue Numbers
Onebutton
120/277VAC
1200
sq. ft. 800W 1200W Ivory
White WS1277I
WS1277W
Onebutton,
120VAC
900
sq. ft. 800WIncandescent
1000WFluorescent
N/A Ivory
White WS120I
WS120W
Onebutton,
277VAC
900
sq. ft. N/A 1800W
Fluorescent Ivory
White WS277I
WS277W
Doublepole
switch,
120/277VAC
1000
sq. ft. 600WIncandescent*
1000WFluorescent*
1800W
Fluorescent White WS1277W2
Two-gangadapterwallplateforWS1277W2tomounttoatwo-gangbox WSAP
*percircuit
H-MOSS® Wall Switches
Passive Infrared Sensors
• Adaptivetechnology-“Installandforget”
operation
• Passiveinfraredtechnology
• Dual120/277VACoperation
• Heavydutyrelay(AT1277)
• Audible alarm before sensor turns
lightsoff(AT1277)
• 1200sq.ft.coverage
• Built in photocell for daylight harvesting
• Nylon wallplate included
AT1277W
ATP1277W
WS1277W
WS120W
WS1277W2
Description 120V AC 277V AC Colour Catalogue Numbers
OneButton 1800WFluorescent 4155WFluorescent Ivory
White AT1277I
AT1277W
OneButton 800WIncandescent
800WFluorescent
1200WFluorescent Ivory
White
Gray
ATP1277I
ATP1277W
ATP1277GY
• Passiveinfraredtechnology
• Manual adjustment time delay
(WS1277-20sec.to30min.)
(WS120/WS277-30sec.to30min.)
• Photocell(WS1277I,WS1277W)
• Duallevelswitchingfromoneortwocircuits
(WS1277W2)
• Nylonwallplateincluded(exceptWS1277W2)
Passive Infrared Wall Switches
Horizontal Coverage Vertical Coverage
WS1277W2WS120, WS277WS1277
14'
35'
14'
Mounting Height
36" to 54"
(91.44 to 137.16 cm)
5°
5°
35'
15°
15°
Mounting Height
36" to 54"
(91.44 to 137.16 cm)
Mounting Height
36" to 54"
(91.44 to 137.16 cm)
16'
16'
35' 35'
Horizontal Coverage Vertical Coverage
RMS101, RMS121, RMS100, RMS120 Horizontal Coverage Vertical Coverage
RMS141, RMS140
Description Coverage 120V AC 277V AC Colour Catalogue Numbers
Standard Nightlight
Single pole
switch with
button,
150°view
800sq.ft. 500W
Incandescent N/A Ivory
White
Almond
LightAlmond
RMS101I
RMS101W
RMS101AL
RMS101LA
RMS101ILI
RMS101ILW
RMS101ILAL
RMS101ILLA
Single pole
switch with
dimming,
150°view
800sq.ft. 500W
Incandescent N/A Ivory
White
Almond
LightAlmond
RMS121I
RMS121W
RMS121AL
RMS121LA
RMS121ILI
RMS121ILW
RMS121ILAL
RMS121ILLA
Heavy duty
switch,
180°view
900sq.ft. 800W
Incandescent
1000W
Fluorescent
1800W
Fluorescent Ivory
White
Almond
RMS141I
RMS141W
RMS141AL
-
-
-
RMS101W
RMS121W
RMS141W
Description Coverage 120V AC 277V AC Colour Catalogue Numbers
Standard Nightlight
Single pole
switch
with button,
150°view
800sq.ft. 500W
Incandescent N/A Ivory
White
Almond
LightAlmond
RMS100I
RMS100W
RMS100AL
RMS100LA
RMS100ILI
RMS100ILW
RMS100ILAL
RMS100ILLA
Single pole
switch with
dimming,
150°view
800sq.ft. 500W
Incandescent N/A Ivory
White
Almond
LightAlmond
RMS120I
RMS120W
RMS120AL
RMS120LA
RMS120ILI
RMS120ILW
RMS120ILAL
RMS120ILLA
Heavy duty
switch,
180°view
900sq.ft. 800W
Incandescent
1000W
Fluorescent
1800W
Fluorescent Ivory
White
Almond
RMS140I
RMS140W
RMS140AL
-
-
-
RMS100W
RMS120ILW
RMS140W
H-MOSS® Wall Switches
Residential and Vacancy Sensors
• Passiveinfraredtechnology
• Photocellequippedfordaylightharvesting
• Auto-on,auto-off
• Delayedoffadjustmentfrom30seconds
to30minutes
• Patentpending“alerttooff”featuredimslights
priortogoingoff(RMS101&121)
• Wallplate included
• C-ULUS
• Passiveinfraredtechnology
• Manual-on,auto-off
• Patentpending“alerttooff”featuredimslights
priortogoingoff(RMS100&120)
• Delayedoff,adjustmentfrom30seconds
to30minutes
• Wallplate included
• C-ULUS
Residential Occupancy Sensors - Passive Infrared
Vacancy Sensors - Passive Infrared - CA Title 24 Compliant
RMS121ILW
RMS120W
22'
64'
45'
12'
23'
32'
Ultrasonic Major
Ultrasonic Minor
Passive Infrared
22'
32'
23'
12'
23'
32'
32'
64'
45'
23'
Ultrasonic Major
Ultrasonic Minor
23'
32'
32'
23'
56'
16'
10 11
ATD2000CRP
ATD2000C
ATU2000CRP
ATU2000C
ATD1000CRP
ATD1000C
ATD500CRP
ATD500C
ATU1000CRP
ATU1000C
ATU500CRP
ATU500C
H-MOSS® Ceiling Sensors
Featuring Adaptive Technology
Adaptive Technology, Dual (Ultrasonic and Passive Infrared)
Combinestheexcellentminormotiondetectionofultrasonicwiththeoutstandingpassive
infrared(PIR)long-rangemajormotiondetection
Coverage Colour Catalogue Numbers
2000sq.ft.withphotocellandisolatedrelay White ATD2000CRP
2000sq.ft. White ATD2000C
1000sq.ft.withphotocellandisolatedrelay White ATD1000CRP
1000sq.ft. White ATD1000C
500sq.ft.withphotocellandisolatedrelay White ATD500CRP
500sq.ft. White ATD500C
Note: All ATD ceiling sensors must use a CU series control unit. See page 11 for details.
Adaptive Technology, Ultrasonic
Excellentminormotiondetection
Coverage Colour Catalogue Numbers
2000sq.ft.withphotocellandisolatedrelay White ATU2000CRP
2000sq.ft. White ATU2000C
1000sq.ft.withphotocellandisolatedrelay White ATU1000CRP
1000sq.ft. White ATU1000C
500sq.ft.withphotocellandisolatedrelay White ATU500CRP
500sq.ft. White ATU500C
Note: All ATU ceiling sensors must use a CU series control unit. See page 11 for details.
• AdaptiveTechnology-“Installandforget”
• All digital sensing technology
• Photocellfordaylightharvestingandrelay
to interface with auxiliary systems such as
HVAC(CRPmodels)
• Non-volatilememory-learnedandadjusted
settings retained after power outage
• 24VDC,33mA
• 32kHz(ATD/ATU500C&CRP-40kHz)
• Mounting base included with sensor
AllH-MOSSceilingsensorswithAdaptiveTechnologycontainthefollowingstandardfeatures:
ATU2000CRP,
ATU2000C ATU1000CRP,
ATU1000C ATU2000CRP, ATU2000C
Hallway Application
ATD2000CRP, ATD2000C ATD1000CRP, ATD1000C
ATP1500CRP
ATP1500C
ATP600CRP
ATP600C
H-MOSS® Ceiling Sensors
Adaptive Technology, Passive Infrared
Outstandinglongrangemajormotiondetection
Description Coverage Colour Catalogue Numbers
Wide view lens 1500sq.ft.withphotocell
and isolated relay White ATP1500CRP
Wide view lens 1500sq.ft. White ATP1500C
High density lens 450sq.ft.withphotocell
and isolated relay White ATP600CRP
High density lens 450sq.ft. White ATP600C
Note: All ATP ceiling sensors must use a CU Series control unit. See page 11 for details.
22' 12'
Passive Infrared
ATP1500CRP, ATP1500C
LVDT200R
LVUS2000R
LVUS1500R
LVPR1500R
Line Voltage Ceiling Mount Sensors - Non Adaptive
Voltage Coverage Load Rating Colour Catalogue Numbers
Dual (Ultrasonic and Passive Infrared)
120VAC 2000sq.ft 2400W White LVDT2000R120
277VAC 2000sq.ft 5000W White LVDT2000R277
Ultrasonic
120VAC 2000sq.ft 2400W White LVUS2000R120
277VAC 2000sq.ft 5000W White LVUS2000R277
120VAC 1500sq.ft 2400W White LVUS1500R120
277VAC 1500sq.ft 5000W White LVUS1500R277
Passive Infrared
120-347VAC 1500sq.ft 800WInc,1000Wfl@120VAC
1800Wfl@277VAC
2200Wfl@347VAC
LVPR1500R
Control Units
HubbellCUseriescontrolunitsprovidea24VDCpowersupplyforATD,ATP,ATUseriessen-
sorsandAdd-A-Relaycombinations.TheCU300Aprovidesa24VDCpowerfor1to4sensor
orsensor/Add-A-Relaycombinationsor1to3forCU347A.Thecontrolunitscontainaninter-
nal relay for the control of an external lighting load. All control units are plenum rated.
Description Catalogue Numbers
347VAC,60Hz,forusewithATD,ATUandATPseriesceilingand
wall mount sensors CU347A
120/277VAC,50/60HzforusewithATD,ATUandATPseries
ceiling sensors and wall mount sensors CU300A
Add-A-Relay
HubbellAARAdd-A-Relaycontainsaninternalrelayforcontrolofanexternallightingload.
TheAARrequiresa24VDCpowersupplyfromtheHubbellCUseriescontrolunit.TheAARis
typicallyusedwhen:1.Itisdesiredtoswitchmorethanonecircuitwhenoccupancyissensed.
2. The lighting load exceeds the maximum rating of the control unit.
Description Catalogue Number
ForusewithCUseriescontrolunitsandHubbellATD,ATU
andATPseriesceilingandwallmountsensors.
AAR
Digital Wall Switch Timer
Description 120V AC 277V AC Colour Catalogue
Number
Dipswitchenabledpresetintervals
-5,15or30minutes
-1,3,6,9or12hours
800W 1200W White DT1277W
DT1277W
CU347A
CU300A
AAR
Accessories
Daylight Controls
H-MOSSDaylightTracker™-HBLDTisauniquephoto-sensingdevicethatutilizesavailable
daylight, saving on energy costs in rooms that are adequately lit. When installed, sufficient
daylight will automatically signal the unit to selectively deactivate the lighting. A dimming unit,
modelHBLDTDBsensesambientlightanddimsICcontrollableelectronicballasts
through0-10Vavailablesignalsaccordingtochangesindaylightandlamplumens.
HBLDTDBautomaticallydimslightingtomaintainpresetlightlevelconditions.
Description Catalogue Numbers
DaylightTracker HBLDT
DaylightTrackerDimming HBLDTDB
Factorycalibratedfootcandlesettings,10-250FC
Note: HBLDT & HBLDTDB must use a CU series control unit (see top of this page for details)
HBLDT
HBLDTDB
OPTIMYZER™
Fluorescent High Bay Occupancy Sensors
MaxloadratingsforACversions:800W@120V,1200W@277V,1500W@347V
Sensorcoverageisdeterminedusinga1:4ratioupto35ft.anda1:1ratioupto45ft.
Example:25ftx1.4=35ftradialcoverage
PhotosensorRange:50-3000FC
Description Catalogue Number
FL.HighBaySensor1SPSTOutput,120-347VAC HMHB21U
FL.HighBaySensor2SPSTOutput,120-347VAC HMHB22U
FL.HighBaySensorw/Photosensor1SPSTOutput120-347VAC HMHB21UP
FL.HighBaySensorw/Photosensor2SPSTOutput120-347VAC HMHB22UP
FL.HighBaySensor24VDC(requirespowerpack) HMHB2LV
FL.HighBaySensorw/Photosensor24VDC(requirespowerpack) HMHB2LVP
FL.HighBayMountingExtensionAdaptor HMHBSA
Key Features
• Digitalpassiveinfrared(PIR)sensor
• Low-profiledesign
• Multiple(singleanddual)outputversions
• UniqueSmartCycling™forimprovedlamplife
• Single and dual timer operation
• ZeroArcPointSwitching
• Supportsmountingheightsupto45ft.
• Area and aisle coverage
• No minimum load
• Universalvoltage—120/277/347VAC
• ETL,UL,cUL,andTitle24compliant
• 5-yearlimitedwarranty
TheH-MOSSOPTIMYZER™FluorescentHighBayOccupancy
Sensor provides the most advanced and accurate passive infrared
(PIR)sensortechnologyforunequaledoccupancydetection
andfalsetripimmunity.ItisspecicallydesignedforON/OFF
controlofhighbayuorescentxturesinwarehouses,distribution
centers, and similar facilities. The sensor easily mounts directly to
industrialT5,T5HOandT8xturesthroughanextended½-inch
chasenipple.ThespeciallydesignedPIRlensprovides1.4:1
coverageupto40feet.Fordeepbodyuorescentxtures,an
extensionadapterisalsoavailableforpositioningthesensorush
orbelowthebottomofthereectorforfulleldofviewcoverage.
This sensor is available with either single or dual outputs, making
ittheperfectsolutionforsingleormultiple-ballastxtures.The
singleoutputsensorfeaturesaprimarytimerforON/OFFcontrol
for maximum energy savings. The dual output sensor features
twotimersformultiplelightlevelcontrol(i.e.stepdimming).The
dualoutputsensoralsoincludesSmartCyclingtechnologywhich
maximizes lamp and ballast life by ensuring that all lamps receive
the same number of switching cycles.
All Hubbell H-MOSS® Occupancy Sensors are covered by a 5 year limited warranty.
Includesanon/offmomentarypushbuttonswitchfeature.
Description Catalogue Number
InfraredCeilingSensorNEMA4AEnclosure ACIPE
Wall Switch Wire Guard AWSG
Wall Mount Wire Guard AWMG
CeilingMountWireGuard ACMG
CeilingMountRacewayAdapter ACMRA
12 13
H-MOSS®
Control Units, Add-A-Relay Daylight
Controls and Digital Wall
Switch Timer
AWSG
AWMG
ACMG
ACIPE
ACMRA
14 15
Load 1
Red
Black
120/277 VAC
Green
Ground
Load 1
Red
Load 2
Violet
Black
Blue
Line circuit
120/277 VAC
Green
Ground
Load 1
Red
Load 2
Violet
Black
Blue
Line circuit 1
120/277 VAC
Line circuit 2
120/277 VAC
Green
Ground
Neutral
Hot
Ground Lighting
Load A
Black Red
Green
Neutral
Hot
Ground Lighting
Load A
Black
Red
Green
Lighting
Load B
Violet
Blue
Wiring Schematic AD, AU, AP, 1277 Series Wall Switch Sensors
Single Circuit Wiring Dual Circuit Sensor, Wired for Dual Circuits Dual Circuit Sensor, Wired for Single Circuit
Single Circuit Sensor wired as 3-Way Sensor Dual Circuit Sensor wired as 3-Way Sensor
Note: Sensor is shipped with all dip switches in the OFF position (factory default).
H-MOSS® Occupancy Sensors
Wiring Schematics
CU Series Control Unit
(Specify Voltage)
White
Black
Red
Red
Lighting Load
Red
Black
Blue
ATD, ATU and ATP Series Sensors**
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
N H
Switch*
* Optional Override Off Switch
White
Black
Red
Red
Lighting Load
N H
Red
Red
Lighting Load
N H
CU Series Control Unit
(Specify Voltage)
Red
Black
Blue
Red
Black
Blue
ATD, ATU and ATP Series Sensors**
Blue
Blk
Red
Blue
Blk
Red
AAR Add-A-Relay
Circuit 1
Circuit 2
White
Black
Red
Red
Lighting Load
N H
Red
Red
Lighting Load
CU Series Control Unit
(Specify Voltage)
Red (+24V)
Black
Blue
Red (+24V)
Black
Blue
ATD, ATU and ATP Series Sensors**
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
White
White
Black
White
CU Series Control Unit
(Specify Voltage)
BlackBlue
CU Series Control Unit
(Specify Voltage)
ATD, ATU and ATP Series Sensors*
*
CU Series Control Unit
(Specify Voltage)
Circuit 1
Circuit 2
White
Black
Red
Red
Lighting Load
N H
N H
Lighting Load
Red (+24V)
Black
Blue
Red (+24V)
Black
Blue
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
Blue
Blk
Red
White BlackBlue
White
Black
Red
Red
White
Ceiling and Wall Mount Sensors
Adaptive Dual Technology, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors
ATD, ATU and ATP Series Ceiling and Wall Mount Sensors
Two Circuit Application:
1to2sensorswiredtocontrolunitandAdd-A-Relay(control
unitswitchescircuit1,Add-A-Relayswitchescircuit2).
**Note: For wiring sensors with isolated relay and photocell option(models with “RP” suffix): Photocell Option: Cap off Blue
sensor wire. Connect Grey sensor wire to Blue control unit wire. Isolated Relay Option: Common-Blue/White wire,
Normally Closed-Black/White wire, Normally Open-Yellow/White wire.
Two Circuit Application:
Two control units wired in two circuits to operate 3 to 6
sensors in a single zone. Maximum 3 sensors per control
unit any sensor will activate both lighting loads.
Single Circuit Application:
Twocontrolunitswiredinparalleltooperate4to6sen-
sors in a single zone. Maximum 3 sensors per
control unit any sensor will activate lighting.
Single Circuit Application:
1to3sensorswiredtocontrolunitwithoptionalover-
ride off switch.
Dual Technology and Ultrasonic Wall Switches
NH
CU Series Control Unit
(Specify Voltage)
Red
Blk
Blue
Red
Blk
Blue
Red
Blk
Blue
Red
Black
Blue
Red
Red
Black
White White
Inboard Ballast
Outboard Ballast
ATD, ATU and ATP Series Sensors**
Single Pole Switch
Single Pole Switch
N
H
CU Series Control Unit
(Specify Voltage)
Red
Blk
Blue
Red
Blk
Blue
Red
Blk
Blue
Red
Black
Blue
Red
Red
Black
White White
ATD, ATU and ATP Series Sensors**
Traveler
3-Way Switch 3-Way Switch
Traveler
Lighting Load
Single Circuit, Dual Level Switching Application:
1to3sensorswiredtocontrolunitwithoptionaloverride
off switches.
Single Circuit, 3-Way Switching Application:
1to3sensorswiredtocontrolunitwithoptionaloverride
off switches.
H-MOSS® Occupancy Sensors
Wiring Schematics
Ceiling and Wall Mount Sensors (continued)
Adaptive Dual Technology, Ultrasonic, and Passive Infrared Ceiling and Wall Mount Sensors
ATD, ATU and ATP Series Ceiling and Wall Mount Sensors
Occupancy and
Vacancy Sensors for an
Energy Conscious World
H-MOSS®
Hubbell Motion Sensing Switches
H2651
Jan/2010
Printed In Canada. Specifications subject to change without notice. ® Registered trademark of Hubbell Incorporated
Hubbell Canada LP • Wiring Products • 870 Brock Road, South • Pickering, ON L1W 1Z8
Phone (905) 839-1138 • FAX (905) 839-9108 • Website: www.HubbellOnline.com