Product Detail Manual

2014-11-11

: Pdf 636287-Attachment 636287-Attachment 768386 Batch12 unilog

Open the PDF directly: View PDF PDF.
Page Count: 5

Packaging
Ballasts
are
packaged either individually
or in
multi-count
cartons. Unless cartons
are
specified
on the
order,
"I"
packs
will
be
shipped, when available.
Abbreviations
UNV
SE
BE
BES
universal
input
voltage
(120V
through
277V)
Side
Exit
Bottom
Exit
Bottom
Exit
with
Studs
Type
Legend
Code
ECF
MCF
ELF
MLF
LFP
HID
HIDC
HIDP
SIGN
Product
Electronic
Compact
Fluorescent
Ballast
Magnetic
Compact
Fluorescent
Ballast
Electronic
Linear
Fluorescent
Ballast
Magnetic
Linear
Fluorescent
Ballast
Linear
Fluorescent
Ballast Part
High
Intensity
Discharge
Ballast
High
Intensity
Discharge
Ballast
Capacitor
High
Intensity
Discharge
Ballast
Part
Magnetic Linear
Fluorescent
SIGN
Ballast
Input
frequency
of
operation
for all
ballasts listed herein
is 60 Hz
u
Stocking
Distributor
Net
Price
Sheet
DPS0101G
Product Code
(UPC
#768386xxxxx)
Individual
Carton
Product
Price
per
Unit
Stocking
Distributor
(GOLD)
Trade
(BLUE)
List
(PINK)
Type
and
Primary
Application/Description
Standard Package
Quantity
Weight
(Ibs.)
ELECTRONIC COMPACT FLUORESCENT BALLASTS (ECF)
20056
20057
20058
19815
19816
19817
20000
20001
20003
19811
19812
19813
-
-
-
20188
20189
19764
19769
19772
-
19921
19922
19923
19036
19039
19033
17814
17816
17815
19999
19032
20002
17817
17820
17818
12285
12286
17824
19089
19092
19086
19079
19083
19076
19928
19098
19101
19095
C213/347BE
C213/347BES
C213/347SE
C213UNVBE
C213UNVBES
C213UNVSE
C218/347BE
C218/347BES
C218/347SE
C218UNVBE
C218UNVBES
C218UNVSE
C240I120RH
C240I277RH
C240PUNVHP-B
C242/347BE
C242/347BES
C242/347SE
C242UNVBE
C242UNVBES
C242UNVSE
C255PUNV-D
C2642/347BE
C2642/347BES
C2642/347SE
$
39.93
$
40.14
$
39.67
$
39.93
$
40.14
$
39.67
$
39.82
$
40.29
$
39.57
$
39.82
$
40.29
$
39.77
$
42.21
$
50.52
$
55.07
$
46.15
$
46.45
$
45.85
$
60.20
$
60.59
$
59.81
$
68.82
$
44.50
$
44.77
$
44.23
$
79.86
$
80.28
$
79.34
$
79.86
$
80.28
$
79.34
$
79.64
$
80.58
$
79.14
$
79.64
$
80.58
$
79.54
$
84.42
$
101.04
$
110.14
$
92.30
$
92.90
$
91.70
$
120.40
$
121.18
$
119.62
$
137.64
$
89.00
$
89.54
$
88.46
$
99.83
$
100.35
$
99.18
$
99.83
$
100.35
$
99.18
$
99.55
$
100.73
$
98.93
$
99.55
$
100.73
$
99.43
$
105.53
$
126.30
$
137.68
$
115.38
$
116.13
$
114.63
$
150.50
$
151.48
$
149.53
$
172.05
$
111.25
$
111.93
$
110.58
ECF
(2)
CFQ13W/G24q
PS
347V
ECF
(2)
CFQ13W/G24q
PS
347V
ECF
(2)
CFQ13W/G24q
PS
347V WHITE
CAN
ECF
(2)
CFQ13W/G24q
PS UNV
ECF
(2)
CFQ13W/G24q
PS UNV
ECF
(2)
CFQ13W/G24q
PS UNV
WHITE
CAN
ECF
(2)
CFQ18W/G24q
PH
347V
ECF
(2)
CFQ18W/G24q
PH
347V
ECF
(2)
CFQ18W/G24q
PH
347V
WHITE
CAN
ECC
(2)
CFQ18W/G24q
PS UNV
ECF
(2)
CFQ18W/G24q
PS UNV
ECF
(2)
CFQ18W/G24q
PS UNV
WHITE
CAN
ECF
(2)
FT40W/2G11
IS
120V
ECF
(2)
FT40W/2G11
IS
277V
ECF
(2)
FT40W/2G11
PS UNV
ECF
(2)
CFM42W/GX24q
PS
347V
ECF
(2)
CFM42W/GX24q
PS
347V
ECF
(2)
CFM42W/GX24q
PS
347V
WHITE
CAN
ECF
(2)
CFM42W/GX24q
PS UNV
ECF
(2)
CFM42W/GX24q
PS UNV
ECF
(2)
CFM42W/GX24q
PS UNV
WHITE
CAN
ECF
(2)
FT55W/2G11
PS UNV
WHITE
CAN
ECF
(2)
CFQ26W/G24q
PS
347V
ECF
(2)
CFQ26W/G24q
PS
347V
ECF
(2)
CFQ26W/G24q
PS
347V WHITE
CAN
20
20
20
20
20
20
20
20
20
20
20
20
10
10
10
20
20
20
20
20
20
10
20
20
20
12.0
12.0
12.0
8.0
8.0
12.0
11.4
12.0
11.4
12.0
12.0
8.0
27.0
27.0
11.0
16.0
16.0
16.0
16.0
16.0
16.0
12.5
12.0
12.0
12.0
*
These
items
are
excluded from standard
distributor
discount;
special
net
pricing
may
be
available
ELECTRONIC
COMPACT
FLUORESCENT
BALLASTS
FOR
Ideal
for
downlights,
surface
mount
&
outdoor
fixtures
Electronic
models
feature
universal
input
volt-
age
from
120V
to
277V.
347V
models
are
TWIN,
QUAD
AND
MULTIPLE
LAMPS
al
Electronic
models
feature
programmed
18
WATTS
raPid
start
r
excellent
lamp
performance
&
auto
reset
shutdown
circuit
TWIN,
QUAD
&
MULTIPLE
LAMPS
18
WATTS
QUICK
REFERENCE
Mag
City
Nominal
lamp
watts
or of
Line CatalogLine Starting
Win
Input
Current Current Ballast Start PowerLead Configuration
Side
Bottom Bottom Starting
WIRING
DIAGRAMS
Wir
Install
in
accordance with
and
configuration
gec
LampS
Volt Number Watts Amps Amps Factor Temp Factor
THD
Exit Exit Exit Studs
Methods
Dim
Diag
National
Electrical
code
Lamp Type
Electrical
Characteristics
- 60 Hz
n'l?
1.00
F
High
<10%
XX
X PRS
CIO
18
U.Uo
0.34
CF^w'/GMq
OR
CFM18W/GX24q
C218UNV*
22
C218UNV-
40
E
J
347
C218/347*
jj
0.98
F
High
<10%
X
1.00
0.98
F
High
<10%
X
X
X
X
PRS
CIO
19
1
X
PRS
CIO
1
9
Quad
or
Multiple,
4-Pin
Lamp
Type
18
Watts
FTI8W/2GI1RS
/Tl
E I
'??
CT218UNVSE*
23
1
20
43
277 42
0.19
0.07
016
1.
00
F
High
<10%
X
0.98
F
High
<10%
X
PRS
CIO
18
PRS
CIO
19
ft
PRS
=
Programmed Rapid Start
* Add
following
suffix
for
complete catalog
#
"SE"
for
Side Exit
connectors
or
"BE"
suffix
for
Bottom Exit connectors
or
"BES"
for
Bottom
Exit
connectors with
2"
O.C. screw studs.
DIAGRAM
18
The
encased
ballasts
listed
on
this page
are
available
in
white
(001)
or
black
(000)
cans.
All
ballasts
are UL
listed.
CSA
approved
and
gnated Class
P
(thermally protected), Type
HL.
DIAGRAM
19
Series lamp operation
§
DIMENSION
DRAWING
FOR
CIO
in
I;
P.I
._i
Leadless-Poke-in
wire connection
M
W»
Lighl
Lighting
Technologies
PAGE
4-15
FOR
MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MAGNETIC
&
ELECTRONIC
COMPACT
FLUORESCENT
BALLASTS
FOR 2D
LAMPS
21
WATTS
Ideal
for
surface
mount
fixtures
All
magnetic models
are
encased
&
potted.
Magnetic
and
electronic
models
available.
Electronic
models feature universal input voltaqe
from
120V
to
277V. 347V models
are
also available.
Electronic models feature programmed rapid
start
for
excellent
lamp performance
&
auto
reset
shutdown circuit
2D
LAMPS
21
WATTS
QUICK
REFERENCE
Nominal
lamp
watts
and
configuration
Lamp
Type
21
Watts
CFS2lW/GRlOq
20,
4-Pin
Mag
Qty
Line Starting
Min
or
of
Line
Catalog®
Input Current Current Ballast Start
Elec
Lamps Volt Number Watts Amps Amps Factor Temp
Electrical
Characteristics
- 60 Hz
M
I
120
4119P»A
24
0.50 0.48 0.81
32° F
M 1 277
4219P»A
23
0.25 0.29 0.85
32° F
M 1
120
4120P»A
24
0.21 0.29 0.81
32° F
M 1 277
4220P**
23
0.07 0.29 0.85
32° F
M 2
120
4122RP»A
38
0.34 0.25
0.72
32° F
M 2 277
4222P»A
46
0.17 0.29 0.81
32° F
E
I
'^
C218UNV*
24
"H?
0.98
0° F
Ll!
U.Uo
E
1 347
C2
18/347*
21
0.06 0.98
0° F
E
2
\:°.
C218UNV*
43
°'"
0.95
0° F
111
0.16
E 2 347
C218/347»
39
0.12
0.95
0° F
Starter required:
use
COP-40
or
FS-4 type fluorescent
starter,
fir
PH
=
Preheat;
PRS =
Programmed Rapid Start
A
Standard cases
offer
side lead
configuration.
Add
"BE"
suffix
for
Bottom Exit design
or
"BES"
for
Bottom Exit Studs design.
* Add
following
suffix
for
complete catalog
#
"SE"
for
Side
Exit
connectors
or
"BE"
suffix
for
Bottom Exit connectors
or
"BES"
for
Bottom
Exit
connectors with
2"
O.C.
screw studs.
Power
Factor
Normal
Normal
High
High
High
High
High
High
High
High
Lead
Configuration
WIRING
DIAC
Side
Bottom Bottom Starting
Wir
Install
in
accordance
»
THD
Exit
Exit Exit
Studs
Methodo
Dim
Diag
Natnal
Electrical
Coc
<20%
XX
X PH C5 5
<20%
X X X PH C3 4
[)]
<20%
XX
X PH C4 5
<20%
XX
X PH C3 5
<20%
XX
X PH C6
12
JRAMS
ith
e.
-
]J
BALLAST
<10%
XX
X PRS
CIO
18
<io%
x x x PRS cm
is
"D|AGRAM4
<10%
XX
X PRS
CIO
19
<10%
XX
X PRS
CIO
19
fnj
The
encased ballasts
listed
on
this
page
are !
[
available
in
white
(001)
or
black
(000)
cans.
K_|f
All
ballasts
are UL
listed,
CSA
approved
and
designated Class
P
(thermally
protected),
Type
HL.
1
BALLAST
\r
DIAGRAM
5
DIMENSION DRAWING
FOR C3, C4, C5
DIMENSION
DRAWING
FOR
CIO
B
A
iu-
C3
C4
C5
2.14"
2.34"
1
.88"
1
.56"
1
.53"
1
.47"
3.50"
5.20"
5.13"
4.31"
6.00"
6.00"
4.75"
6.59"
6.44"
0.22"
0.31"
0.25"
C10
2.31" 1.00" 4.25" 4.61" 4.94" 0.98" 1.00"
Leadless-Poke-in
wire connection
DIAGRAM
9
Parallel lamp operation
Lead Lengths:
Side-12"
BE/BES-8"
DIMENSION
DRAWING
FOR C6
0
C6
2.40" 1.55" 8.31" 8.89" 9.50"
1.19'
DIAGRAM
12
Series
lamp operation
Lead Lengths:
Side-12"
BE/BES-
DIAGRAM
19
Series lamp operation
Universal
Lighting
Technologies
PAGE
4-23
DIAGRAM
18
FOR
MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Configurations
Standard Side Exit
Bottom
Exit*
Bottom
Exit
with
Studs**
Standard
Side
Exit-Both
Ends
Electronic
Side
Exit
Electronic
Bottom
Exit
0)
o
O
Q.
0
Electronic
Bottom
Exit
with
Studs
For
full versatility
in
application according
to
various fixture requirements,
Universal
manufactures encased ballasts
in
three lead
and
mounting options.
This catalog
lists
ordering codes
for
standard side exit
units.
*Bottom
exit units
should
be
ordered with suffix
"-BE"
attached
to the
catalog number.
"Bottom
exit
with studs should
be
ordered with suffix
"-BES"
attached
to the
catalog
number. (Example: Standard Unit:
"4000P";
Bottom Exit unit "4000-BE"; Bottom
Exit
with Studs:
"4000-BES").
W
un
Ligh!
Lighting
Technologies
PAGE
4-4
FOR
MORE INFORMATION
CALL
1-800-BALLAST
(225-5278)
Understanding Universal Part Numbers
MAGNETIC
Our
part number nomenclature
for
magnetic ballasts
is
shown below:
Odd
=
NPF
Even
=
HPF
Thermally
Protected
4XXX
XX
PXXX
XXX X
1
-120V
2
-
277V
3
-
347V
1
^
'
F1 -
Frame
F2
-
Fr.
w/feet
H2
-
Cover/Fr.
No
suffix
-Side
Exit
BE
-
Bottom
Exit
BES
-
Bottom
Exit
with
Studs
P
Partnn
T
-
Tray
Pack
Example:
4123PBESOOOT
Ballast
for CFL
Lamps: Indicated
by "4"
prefix
Voltage:
120V
Lamp
Type:
26W
Quad Lamp (refer
to
catalog
for
wattage)
Power
Factor: Normal
Encased
and
Potted: Indicated
by
absence
of
F1,
F2,
orH2)
P:
Thermally protected
BES:
Bottom exit leads
with
studs
000:
Color—Black
T:
Packaging container
style—Tray
Pack
These
ballasts
are
available
for a
wide variety
of
applications
with
lamps, voltages, mounting configurations,
and
performance characteristics.
For
more detailed information,
just identify
the
lamps
to be
ballasted
and
work forward
to
determine
the
ballast part number.
ELECTRONIC
Our
nomenclature
for
electronic
CFL
ballasts follows
the
system already
in
place
for
other Universal electronic
ballasts.
The
exceptions
are
that
the
model number
prefix
for
compact fluorescent
is a C
rather than
a
B—and
the
suffixes
for the
mounting configuration
will
be the
same
as
those used
for
magnetic products
(BE
and
BES).
If you
don't
see
these suffixes,
the
ballast
has
traditional side exit leads.
Lamp
Wattage
UNV
or
347V
Coior:001-White
000-Black
folia
CXXX
XX. XXX
.XXX
XXX X
imps
'
SPrSeries.
Rapid
Start
R-Rapid
Start
No
suffix
or
SE
-
Side
Exit
BE
-
Bottom
Exit
BES-Bottom
Exit
with
Studs
C-Carton
T-Tray
Pack
l-lndividual
Example:Electronic
C240PUNVHP-B
Ballast
Type:
C CFL
Electronic Ballast
Lamp
Qty:
2
Lamp
Type:
40W
TT5,
4 Pin
(FT40W/2611)
P:
Programmed Rapid Start
Voltage:
UNV
120
to
277
volts
HP-B: High Performance
<10%;
low
profile
can
000:
Color—Black
C:
Packaging container
style—Carton
Pack
Colors
000
-
Black
001
-
White
Lamp
Wattage'
120V,
277V
347V.
UNV
(120-277)
CXXX
X XXX XXX XXX X
f of
Lamps
No
suffix
P=Progrc
=P
mmed
Rapid
Start
Ulnstant
Start
SE
-
Side Exit
BE
-
Bottom
Exit
BES
-
Bottom
Exit/Studs
HP-B
-
Low
Profile
RH
-
Reduced
Harmonics
I
T
=
Tray
Pack
C
-
Carton
Pack
I
-
Individual
r»
i
£
m
W
tfn
LigN
Example:
C213UNVBESOOOC*
Ballast
Type:
C
Lamp
Quantity:
2
Lamp
Type:
13W
Quad,
4 Pin
(CFQ13W/G24q)
Voltage:
UNV
120
to
277
volts
BES:
Bottom exit connection, studs
OOOC:
Color—Black
C:
Packaging container
style—Carton
Pack
'Exception
is
C2642, which does
not
distinguish
number
of
lamps.
See
catalog.
Lighting
Technologies
PAGE
4-7
FOR
MORE INFORMATION CALL
1-800-BALLAST
(225-5278)