6485_000i Viii

2014-07-04

: Pdf 656274-Attachment 656274-Attachment 000788 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 312 [warning: Documents this large are best viewed by clicking the View PDF Link!]

IV
Table of Contents
See the World in a New Light I
Product Selection Guide II–III
ECOLOGIC®V–VI
Energy and the Cost of Lighting VII
mySYLVANIA.com VIII
Glossary of Terms IX–XI
SYLVANIA Incandescent Lamps 1
SYLVANIA Tungsten Halogen Lamps 34
SYLVANIA Miniature Lamps 58
SYLVANIA High Intensity Discharge (HID) Lamps 62
SYLVANIA Fluorescent Lamps 95
SYLVANIA Compact Fluorescent Lamps 105
Starters 138
SYLVANIA Electronic Ballasts 144
SYLVANIA Magnetic Fluorescent Ballasts 155
SYLVANIA Magnetic HID Ballasts 160
OSRAM Photo-Optic Specialty Lamps 171
OSRAM PLANON®Lamps 239
OSRAM LED Lamp Modules 240
Product Warranties 266
Manufacturers’ Cross Reference 272
Index 298
Lamp & Ballast Product Catalog
The data and suggested applications contained in this catalog, as well as any additional information our
representatives may be able to furnish, are for general information only and are not intended and should not
be taken as representations or warranties as to the suitability of a lamp for any particular application or use in
any particular equipment, nor are our representatives authorized to make any such representations or give any
such warranties.Applications and conditions of use are many and varied and beyond our control.We do not
have the same degree of knowledge that the purchaser has with respect to the design of his equipment and
the conditions of its use.Therefore, it is up to the purchaser to make his own determination as to the suitability
of a lamp for his intended application or use and to assume responsibility for that determination.
OSRAM SYLVANIA claims to supply the best possible products at all times. For this reason, OSRAM SYLVANIA
reserves the right to make changes in its products when it believes such changes will improve its products.
The specifications and information shown in this catalog are believed to be accurate.Although OSRAM
SYLVANIA believes this information to be correct, no warranty is made or implied as to the accuracy of this
information and OSRAM SYLVANIA does not accept or assume responsibility of liability for errors, changes,
omissions, or for harm resulting therefrom.
In accordance with our established policy to consistently improve our products, the specifications contained
herein are subject to change without notice.
The OSRAM SYLVANIA Test and Measurement Laboratory is a participant in the Energy Efficient Lighting (EEL)
Program of the National Voluntary Laboratory Accreditation Program (NVLAP-NIST) and is accredited for testing
of lighting products according to the guidelines for the EEL Program. OSRAM SYLVANIA lamp and ballast
measurements are conducted under laboratory conditions utilizing American National Standards Institute
(ANSI), Canadian Standards Association (CSA), Commission Internationale de l’Eclairage (CIE), and Illuminating
Engineering Society of North America (IESNA) standards and practices.The OSRAM SYLVANIA Electronic
Component and Systems Development Group participate in the Underwriters Laboratories Inc. Client Test Data
Program. Ballast designs are tested for conformance to Underwriters Laboratory (UL) safety standards using
practices audited, assessed and approved by UL.Actual lamp and ballast performance may vary depending on
application and environment (i.e. ambient temperature,input voltage, ballast type,etc.)
OSRAM SYLVANIA designs and manufactures lamps and ballasts to meet American National Standard Institutes
(ANSI) and/or IEC (International Electrotechnical Commission) standards of construction and performance
through Total Quality Manufacturing (TQM) practices where applicable. In addition, ballasts are designed and
manufactured to meet Underwriters Laboratory (UL) and Canadian Standards Association (CSA) safety standards
as necessary.Ratings may change as a result of changes made to remain compliant with modified or updated
standards. OSRAM SYLVANIA will release new or updated technical bulletins when appropriate.All product data
presented in this catalog supersedes all data published before 2/4/04.
Many OSRAM SYLVANIA products listed in this catalog qualify under the North American Free Trade Agreement
(NAFTA) as manufactured in Canada, the United States of America or Mexico.
Important Notice
V
Energy
For our customers, installing energy-efficient lighting is one of the most effective,sustainable
design strategies available today. Reduced energy usage means reduced utility emissions, which
means reduced environmental impact.
At OSRAM SYLVANIA we have long been the energy-efficient product innovators.We were first with
high performance T8 fluorescent lamps in North America. In 1981 we introduced the SYLVANIA
OCTRON®family of fluorescent lamps, ushering in a new era of lighting efficiency. For years we
have offered our customers optimal design and energy performance with The SYSTEM SOLUTION
concept-- our inventive offering of energy-efficient SYLVANIA lamps and ballasts.By bringing lamp
and ballast development under one roof, we have been able to design SYLVANIA lighting systems
that optimize energy savings without sacrificing other elements of performance.
OSRAM SYLVANIAs innovative program of environmental responsibility—
ECOLOGIC®—was designed as a thorough approach to reducing the
environmental impact of our processes, packaging and products.
Today, ECOLOGIC is even more comprehensive, having evolved to
include other elements of sustainability, such as source reduction
and reuse, recycling and recyclability, and environmental management
systems in product manufacturing.
Sustainability in Action
VI
Source Reduction and Reuse
OSRAM SYLVANIA pioneered the use of lead-free solders and weld-
ed lamp bases, as well as the use of lead-free glass in high intensity
discharge (HID) light sources.We have eliminated lead solder in the
majority of SYLVANIA general purpose incandescent A-19,B-10, and
globe-shaped lamp products; most of our halogen lamp types are
lead-free.We also offer the only lead-free, mercury-free high-pres-
sure sodium lamp on the market, and have won acclaim from the
lighting community for this research and development breakthrough.
Since 1990, OSRAM SYLVANIA has joined the lamp industry in
reducing mercury content in total U.S. lamp shipments by 67%,
and in four-foot fluorescent lamps by an average of 80%.Our New
Hampshire plants have instituted innovative programs to reclaim
unused metal halide and high-pressure sodium arc tubes.
Over the past 15 years,OSRAM SYLVANIAs packaging department
has aggressively pursued source reduction strategies, reducing the
thickness and combined weight of both primary and secondary pack-
aging for all of our products.Through advanced computer software
and scientific methods,we have optimized packaging systems from
primary through secondary to unit load,saving packaging materials,
pallets,fuel,transportation, and warehouse space,without compro-
mising shipping performance.These benefits extend through the
entire supply chain.Our lamp components and highest volume pack-
aging raw materials are typically shipped in re-usable containers, and
all packaging is printed using organic soy-based (non-solvent) inks.
Recycling Philosophy
OSRAM SYLVANIA publicly promotes recycling as the preferred method
of lamp disposal.As a matter of policy,our own warehouse and manu-
facturing locations recycle broken lamps.When our SYLVANIA Lighting
Services personnel complete lighting retrofits or maintenance calls, we
ship all spent mercury-containing lamps to a bona-fide lamp recycler
for processing.Furthermore,we encourage distributors and retailers
of our SYLVANIA products to offer lamp-recycling programs to their
customers,thereby reducing the burden on the solid waste stream.
Recycled and Recyclable Materials
We use only recycled mercury in our energy-efficient fluorescent
and HID products. 95% of SYLVANIA packaging comes from renew-
able resources, and 90% of high volume packaging is made from
post-consumer or post-industrial recycled materials.Virtually all of our
lamp packaging is recyclable.
OSRAM SYLVANIA recommends that all mercury-containing lamps
that are discarded by non-residential users should be recycled,
regardless of any exemptions that users may have under their state
or local laws. Information about lamp recycling,and individual state
rules for lamp disposal, can be found at www.lamprecycle.org.
SYLVANIA ECO®Products
ECOLOGIC®is more than just a single product
solution to today’s environmental issues;
SYLVANIA ECO products comprise an entire
family of lighting options guided by our unique
life-cycle approach to product development.
This approach places strict environmental focus
on all stages of lamp life, driving our continual
search for improvementand we have more
ECO products than any other lamp manufacturer
in North America.
SYLVANIA ECO products are engineered to pass the
Federal TCLP test for hazardous waste determination:
•Tested in accordance with EPA SW846
•Prepared for testing in accordance with
NEMA LL series standards
ECO products also feature some or all of the following:
Reduction or elimination of toxic materials
Lamp bases using lead-free solders
Welded lamp bases
Lead-free glass in HID products
Precision dosing systems ensuring consistent
low mercury content
Performance equal to or better than standard,
non-ECO products
ECO-friendly packaging,using recycled materials
and soy-based inks
Permanent ECO identifier printed on lamp
or stamped into metal base
Long life with sustained performance
High efficacy
VII
Calculating Costs
Lighting represents 30 to 50 percent of operating costs in a typical
installation. Electricity alone represents 86 percent of those costs,
on average, with 11 percent going to maintenance and only 3 per-
cent actually being spent on lighting hardware. Obviously, selecting
the most energy efficient lighting systems is the key to getting the
best possible return on your lighting investment.
Minimize Operating Costs
Understanding the basic equations of lighting economics makes it
easy to see that long-term operating costs are the most important
cost factor, not the initial investment in lamps,ballasts or other
hardware. In both retrofits and new installations, it is the overall
reductions in energy costs which pay back the initial investment
and provide substantial long-term returns.
Inefficient lighting systems waste energy and money. In a typical commercial
application, lighting can represent 30-50 percent of operating costs. An invest-
ment in energy efficient lighting systems from OSRAM SYLVANIA can reduce
these costs and offer an excellent return on investment.
Energy and the Cost of Lighting
SYLVANIA OCTRON®QUICKTRONIC®
System Solutions Provide Substantial Savings
DULUX®Lamps
Offer Significant
Savings
Initial Cost
of Lighting Upgrade
Total Energy Cost
Savings per Year
Years
Simple Payback
Annual Energy Cost Savings Worksheet
Use this 3-part calculation to determine the estimated annual
energy cost savings resulting from an upgrade of one lamp
or system type throughout a facility.This annual cost savings
figure may be compared with the cost of the upgrade to
determine simple payback and rate of return (ROR).
NOTE: For fluorescent systems,substitute “lamp” with
“system” or “fixture”so that ballast watts are included.
Original
Lamp Wattage
Replacement
Lamp Wattage
Watts Saved
per Lamp
# of Lamps
to Replace
Total Watts
Saved
Total Kilowatts
Saved
Total Kilowatts
Saved
Hours of Use
per Day
Days of Use
per Week
Weeks of Use
per Year
X
÷1000
X
X
X
Compute the total
energy (kilowatt
hours, kWh) saved
annually by
performing this
upgrade
2.
3. Total kWh
Saved per Year
Your Energy Cost
per kWh (typically $0.10)
Total Energy Cost
Savings per Year
X
=
=
Compute the
total energy cost
savings per year
Simple Payback
Rate of Return
(ROR) ÷100
÷
%
Over the long service life of
DULUX compact fluorescent
lamps, their low energy usage
provides a substantial return
on investment compared to
incandescent lamps with an
equivalent light output (savings
based on $0.10 per kWh).
* approximate retail cost
Compared with a conventional F40T12 SS 4-lamp magnetic system, a SYLVANIA OCTRON
FO32T8/QUICKTRONIC 32 LP System Solution can return more than $200 in energy savings
over a 10-year period (savings based on $0.10 per kWh operated 4000 hours/year).
Compute the total
power (kilowatts,
kW) saved by
upgrading older
lamps to energy
saving SYLVANIA
replacements
1.
$
$125 ___
$100 ___
$75 ____
$50 ____
$25 ____
$200
$150
$100
$50
$0
YEAR: 012345678910
-$50 Payback Period Net Savings
Energy
Cost
$100
Net
Savings
$76
Energy
Cost
$23
Lamp Cost
$17.50*
Lamp Cost
$16.50*
(10 X $1.65)
100W Incandescent DULUX EL 23W
Your Resource Solution Site
• Electronic Catalog
• Industry Links
• Training
Transaction Details for Partners
Energy Savings Calculator
• Product Specification
• ECOLOGIC®Certification Program
Energy Saver Certification Program
We invite you to visit us online at www.mySYLVANIA.com/register to learn about the many
lighting solutions available for today’s modern lighting applications. Good lighting is more
than just pleasing to the eye. It’s a smart, cost-effective way to improve both safety and
productivity in the workplace. With SYLVANIA products, you can actually cut your lighting
costs and save on lamp replacement and labor costs while improving lighting quality. We
understand the needs of the commercial marketplace and have developed a wide variety of
lighting solutions specifically designed for you. Your portal features:
VIII
IX
Ampere
A unit expressing the rate of flow of
electric current.
ANSI (American National Standards
Institute)
The organization that develops
voluntary guidelines and produces performance
standards for the electrical and other industries.
Audible Noise (Sound)
All fluorescent lamp
ballasts produce some noise. Most OSRAM
SYLVANIA brand ballasts are sound rated A (up
to 75% quieter than magnetic types) and are
acceptable for most applications. Care should
be taken when mounting the ballast to reduce
vibration.
Average Rated Life
An average rating, in hours,
indicating when 50% of a large group of lamps
have failed, when operated at nominal lamp volt-
age and current; manufacturers use 3 hours per
start for fluorescent lamps and 10 hours per start
for HID lamps when performing lamp life testing
procedures; every lamp type has a unique mortali-
ty curve that depicts its average rated life. For
Photo-Optic specialty lamps, average rated life
refers to the operating period after which on statis-
tical average, 50% of the lamps will perform within
their specified values.
Ballast
A device used with an electric discharge
lamp to obtain the necessary circuit conditions
(voltage, current and waveform) for starting and
operating; all fluorescent and HID light sources
require a ballast for proper operation. Dimming
ballasts are special ballasts which, when used
together with a dimmer, will vary the light output of
a lamp. OSRAM Photo-Optic discharge lamps are
either designed for AC operation (sine wave and/or
square wave with recommended operational fre-
quencies below 1KHz) or DC operation (current
regulated or power regulated). Please see OSRAM
lamp specifications for correct ballast or electronic
control gear selection.
Ballast Basics
Ballasts have two primary func-
tions: 1) start the lamp and 2) control operation
of the lamp once it has started. High frequency
electronic ballasts operate lamps more efficiently
and eliminate the hum and visible flicker normally
associated with standard magnetic ballasts.
Electronic ballasts also typically have better power
quality than magnetic ballasts.
Ballast Efficacy Factor (BEF)
Ballast factor (as
a whole number) divided by input power (watts).
Used to measure the level of efficiency of similar
ballast models. For example, the OSRAM SYLVA-
NIA QT2X32IS which has a ballast factor of 0.90
and input watts of 59 (BEF= 90/59 = 1.53), is
more efficient than electronic ballasts with ballast
factor of 0.875 and input watts of 62 (BEF=1.41).
Ballast Factor (BF)
The measured ability of a
particular ballast to produce light from the lamp(s)
it powers; ballast factor is derived by dividing the
lumen output of a particular lamp/ballast combina-
tion by the lumen output of the same lamp(s) on a
reference ballast.
Ballast Fusing
(See Fusing.)
Ballast Life
OSRAM SYLVANIA ballasts are
designed to have an average life expectancy of
60,000 hours. To maximize life, ambient temperature
should be kept as low as possible. It is also impor-
tant to maintain effective dissipation of heat using the
lighting fixture as a heatsink for the ballast enclosure.
Ballast Losses
Power consumed by a
ballast that dissipates as heat instead of being
converted into light. Electronic ballasts operate
more efficiently than magnetic or hybrid ballasts. A
typical ballast loss for a standard two lamp energy
saving magnetic ballast is 12 watts, where an
electronic equivalent would only be 7 watts.
Ballast Types
There are three types of lighting
ballasts: 1) Magnetic: an inefficient device that
uses a core and coil assembly transformer to
perform the minimum functions required to start
and operate the lamp; 2) Hybrid or “low frequency
electronic”: essentially a magnetic ballast with a
few electronic components that switch off voltage
to the lamp coil once the lamp has started. A mini-
mal increase in efficiency is obtained via more
expensive magnetic core material and the absence
of power to the lamp coils during operation; 3) High
frequency electronic: a ballast that operates lamps
at frequencies above 20,000 Hz. Maximum efficien-
cy is obtained through the use of electronic circuitry
and optimum lamp operating characteristics.
Base
The lamp base mechanically holds the lamp
in place in the application. The lamp base directly
or indirectly (via a cable or lead-in wires) conducts
electricity from the circuit to the lamp and can be
designed to dissipate heat. Lamp bases should be
operated within specified temperature ranges.
Beam Angle
The angle between the two direc-
tions for which the intensity (candlepower) is 50%
of the maximum intensity as measured in a plane
through the nominal beam centerline (center beam
candlepower).
Beam Spread
In any plane, the angle between
the two directions in the plane in which the candle-
power is equal to a stated percent of the maxi-
mum candlepower in the beam.
Black Body (Planckian radiator)
An ideal
thermal radiator whose SPD curve is defined by its
temperature in Kelvin and whose color coordinates
lie exactly on the Planckian curve.
Brightness
(See Luminance.)
Bulb
Hard, soft or quartz glass enclosure, which
can contain a vacuum, elemental inert gas or
metal and a means of light generation (filament or
electrodes).
Candela (cd)
The unit of measure indicating the
luminous intensity (candlepower) of a light source
in a specific direction; any given light source will
have many different intensities, depending upon
the direction considered.
Candlepower Distribution
A curve that repre-
sents the variation in luminous intensity (expressed
in candelas) in a plane through the light center of a
lamp or luminaire; each lamp or lamp/luminaire
combination has a unique set of candlepower dis-
tributions that indicate how light will be spread.
Center Beam Candlepower (CBCP)
The
intensity of light produced at the center of a
reflector lamp beam, expressed in candelas.
Chromaticity
The aspect of color that includes
consideration of its dominant wavelength and purity.
Color Rendering Index (CRI)
The Color
Rendering Index (CRI) measures the effect a light
source has on the perceived color of objects and
surfaces. High CRI light makes virtually all colors
look natural and vibrant. Low CRI causes some
colors to appear washed out or even to take on a
completely different hue.
Color Temperature (CT)
Color temperature,
which is measured in Kelvin, indicates whether a
lamp has a warm, midrange or cool color appear-
ance. “Warm” light sources have a low color tem-
perature (2000-3000K) and feature more light in
the red/orange/yellow range. Light with a higher
color temperature (>5000K) features more blue light
and is referred to as “cool.”
Compact Fluorescent Lamps
Compact
fluorescent lamps employ small diameter tubes that
are bent so they begin and end in a single base.
This allows them to be produced in a wide variety
of configurations, greatly extending the applica-
tions for fluorescent lighting.
Correlated Color Temperature (CCT)
A specification of the color appearance of a
lamp, relating its color to that of a reference
source, black body radiator, heated to a particu-
lar temperature, measured in degrees Kelvin (K);
CCT generally measures the “warmth” or “cool-
ness” of light source appearance.
Current
A measure of the rate of flow of
electricity, expressed in amperes (A).
Description
(See Ordering Abbreviation.)
Design Amperes
The approximate current
which the lamp will draw at design volts.
Directional Lighting
Illumination on the work-
plane or on an object predominantly from a single
direction.
Double-Ended
Lamps that have two bases
opposite one another for series electrical connec-
tion, mechanical mounting and heat dissipation.
Efficacy
The rate at which a lamp is able to con-
vert power (watts) into light (lumens), expressed in
lumens per watt (LPW or lm/W). See also LPW
Performance.
Electronic Control Systems
(See Ballast.)
EMI/RFI
Electronic Ballasts contain circuits that
limit electrical noise conducted onto the power line
or radiated through the air, otherwise referred to as
EMI/RFI. OSRAM SYLVANIA ballasts comply with
FCC 47 CFR Part 18, non-consumer limits for
commercial applications. Ballasts for residential
application must meet consumer limits. OSRAM
SYLVANIA has a complete line of magnetic bal-
lasts for residential use.
Product Catalog Glossary of Terms
X
Energy
A measure of work done by an electrical
system over a given period of time, often
expressed in kilowatt-hours (kWh).
Filament
A tungsten wire purposely positioned
inside a lamp bulb, that when heated electrically
generates radiation in the visible, infrared and ultra-
violet ranges. Tungsten material is most often
used, as it has great tensile strength, is very
durable, and can be heated very near its melting
point without evaporating rapidly. Lamp filaments
are offered in a variety of designs optimized for
specific applications.
Fixture
(See Luminaire.)
Floodlight
A reflector lamp with a relatively wide
beam pattern. Also a luminaire consisting of lamp
and reflector at fixed distance providing a wide
field of illumination.
Fluorescent Lamp
A low pressure mercury
vapor discharge light source. The electric discharge
generates ultra-violet (UV) energy, which is absorbed
by a phosphor and converted to visible light.
Focal Distance
The distance between a lamp
(light producing element) and the focal point of
the reflector surrounding it. Lamp alignment can
be adjusted to influence both illumination and
color quality. Sometimes referred to as “working
distance”.
Footcandle (fc)
A unit of illuminance equal to
1 lumen per square foot.
Frequency
The number of times per second that
an alternating current system reverses from posi-
tive to negative and back to positive, expressed in
cycles per second or hertz (Hz).
Fusing
All QUICKTRONIC®ballasts contain
inherent electrical protection. Although there is
no need to externally fuse the ballast, should
code or regulation require one, 3 amp slow blow
fuses are recommended.
Glow to Arc Transition
In order to achieve full
rated lamp life, a ballast should start a lamp so
that the time from when the lamp begins to glow
to the time the lamp arc strikes should be as short
as possible. OSRAM SYLVANIA instant start bal-
lasts typically accomplish this task within 50 msec.
Grounding
The ballast case and fixture must
always be grounded. The grounding helps assure
safety, proper lamp starting, and acceptable EMI/RFI
performance. Install ballast in accordance with nation-
al and local electric codes.
Halogen Lamps
High pressure tungsten
filament lamps containing halogen gases. The
halogen gases allow the filaments to operate at
higher efficacies than incandescent lamps.
Halogen lamps also provide brighter, whiter light
with better color characteristics, longer service
life and improved energy efficiency.
Harmonic
An electrical frequency that is an
integer multiple of the fundamental frequency; for
example, if 60 Hz is the fundamental frequency,
then 120 Hz is the second harmonic and 180 Hz
is the third harmonic. Some electronic devices,
such as ballasts or power supplies, can cause
harmonic distortion, directly affecting power quality.
Hertz (Hz)
A unit of frequency equal to one cycle
per second; see frequency.
High-Intensity Discharge (HID) Lamps
Lamps in which an arc passing between two elec-
trodes in a pressurized tube causes various metallic
additives to vaporize and release large amounts of
light. All HID lamps offer outstanding energy effi-
ciency and service life. Metal halide lamps also
offer good to excellent color rendering index (CRI).
Hot Ignition
The restarting of a previously
operating lamp shortly after turn-off. Hot ignition
is a high performance feature in many OSRAM
SYLVANIA discharge lamp types.
Illuminance
Light arriving at a surface, expressed
in lumens per unit area; 1 lumen per square foot
equals 1 footcandle, while 1 lumen per square
meter equals 1 lux.
Incandescent Lamp
A light source using
the principle of incandescence. When an electric
current passes through a filament wire (usually tung-
sten), the heated wire glows. Filaments of standard
incandescent lamps are enclosed in a vacuum or
gas-filled bulb. They provide low initial cost, good
color rendition and excellent optical control.
Instant Start (IS)
Instant start ballasts apply high
voltage across the lamp with no preheating of the
cathode. This is the most energy efficient starting
method for fluorescent lamp ballasting. IS ballasts
use 1.5 to 2 watts less per lamp than rapid start
ballast. Other IS ballast benefits typically include
parallel lamp circuitry, longer remote wiring dis-
tance, easier installation due to less complicated
wiring, and capability to start lamps at 0 degrees
(versus 50 degrees F for rapid start).
K-Factor
A measurement that quantifies the
effect of non-linear equipment, such as lighting
ballasts, on an electrical system. Lighting systems
should be designed so that the transformer rating
is sufficient for the ballast used (typically K-factor
<4). All OSRAM SYLVANIA ballasts meet this
specification.
Lamp
Manufactured light source, synonymous
with light bulb; the three broad categories of
electric lamps are incandescent, fluorescent
and high-intensity discharge.
Lamp Current Crest Factor (LCCF)
The ratio
of peak lamp current to the RMS (average) lamp
current. Lamp manufacturers require a LCCF of
less than 1.70 in order to achieve full lamp life.
Lamp Disposal
When disposing of spent lamps,
always consult federal, state, local and/or provincial
hazardous waste disposal rules and regulations to
ensure proper disposal.
Lamp Flicker
Cyclic variation in output of a light
source. High frequency electronic ballasts provide
a minimal level of lamp flicker. Lamp flicker from
magnetic ballasts may cause eye fatigue for some
people.
Lamp Fuse
Wire or device designed to protect a
lamp from over-voltage or over-current conditions.
OSRAM requires that all Photo-Optic lamps be
fused in their applications to prevent lamp over-
powering. Certain lamps contain their own internal
fuse. Please ensure lamps in your specific applica-
tion are fused with respect to their power source.
Lamp Lumen Depreciation Factor (LLDF)
The multiplier to be used in illumination calcula-
tions to relate the initial rated output of light
sources to the anticipated minimum rated output
based on the relamping program to be used.
(See Lumen Depreciation and Mean Lumens.)
Lens
A glass or plastic element used in luminaires
to change the direction and control the distribution
of light rays.
Light
Radiant energy that is capable of producing
a visual sensation.
Light Center Length (LCL)
The distance from
a specified reference point on a lamp base
to its light center.
Light Loss Factor (LLF)
A factor used in
calculating illuminance after a given period of time
and under given conditions. It takes into account
temperature and voltage variations, dirt accumula-
tion on luminaire and room surfaces, lamp depre-
ciation, maintenance procedures and atmosphere
conditions. Formerly called maintenance factor.
Low Temperature Starting
QUICKTRONIC®
instant start and programmed rapid start electron-
ic ballasts have the capability to start fluorescent
lamps at temperatures down to 0°F providing the
following conditions are met: 1. The ballast is
operated at rated nominal line voltage; 2. Ballast
cannot be tandem/remote wired for low tempera-
ture starting applications. Please note, starting
time may increase at 0°F ambient temperatures.
Enclosed fixtures are recommended as fluores-
cent lamps have reduced light output at cooler
ambient temperatures. (See specifications for
each model’s starting temperature rating.)
LPW Performance
Lumens Per Watt. The
number of lumens produced by a light source for
each watt of electrical power supplied to the light
source. Also see Efficacy.
Lumen Depreciation
The decrease in lumen
output of a light source over time; every lamp type
has a unique lumen depreciation curve (sometimes
called a lumen maintenance curve) depicting the
pattern of decreasing light output. See Lamp Lumen
Depreciation Factor, LLDF and Mean Lumens.
Lumen Maintenance
(See Lumen Depreciation.)
Lumens (lm)
A unit of luminous flux; overall light
output; quantity of light, expressed in lumens. For
example, a dinner candle provides about 12
lumens and a 60-watt soft white incandescent
lamp provides about 840 lumens.
Luminaire
A light fixture; the complete lighting
unit, including lamp, reflector, ballast, socket,
wiring, diffuser and housing.
Luminaire Efficiency
The ratio of luminous flux
(lumens) emitted by a luminaire to that emitted by
the lamp or lamps used therein.
Luminance (L)
Light reflected in a particular
direction; the photometric quantity most closely
associated with brightness perception, measured
in units of luminous intensity (candelas) per unit
area (square feet or square meters).
XI
Luminance Contrast
The relationship between
the luminances of an object and its immediate
background.
Luminance Ratio
The ratio between the
luminances of any two areas in the visual field.
Lux (lx)
A unit of illuminance equal to 1 lumen
per square meter.
Maximum Case Temperature
All OSRAM
SYLVANIA electronic ballasts have a maximum
allowable case temperature of 70°C and 90°C
for magnetic fluorescent ballasts. Applications
in which the case temperature exceeds this
maximum void all warranties.
Maximum Overall Length (MOL)
The total
length of a lamp, from top of bulb to bottom
of base.
Mean Lumens
Lumen output of a light source
after the source has been used. Mean lumen
values for fluorescent and HID lamps are typically
measured at 40% of their rated lives. Most high
pressure sodium and mercury lamps are meas-
ured at 50% of their rated lives. All measurements
are made on ANSI reference ballasts. Mean
lumens are not typically measured for incandes-
cent and tungsten halogen lamps.
Mean Spherical Candela (MSCD)
The average
value of the luminous intensity of a light source
in all directions. To convert MSCD to Lumens,
multiply by 4π(12.57).
Mean Time Between Failures (MTBF)
A calculation of ballast life based on thermal
conditions, component values, and circuit
characteristics used to develop relative predic-
tions of ballast life. OSRAM SYLVANIA uses
methodology that typically provides a 1:10 actual
life prediction based on MTBF calculations.
NAED
A five-digit number used to identify a spe-
cific OSRAM SYLVANIA lamp. This NAED number
in this catalog is labeled Product Number and
should be used when ordering OSRAM SYLVANIA
products. NAED is the abbreviation for National
Association of Electrical Distributors.
Nanometer (nm)
A unit of length equal to 10-9
meters; commonly used as a unit of wavelength.
Nominal Watts
Wattage used to describe a
lamp. Also see Power and Watt.
OFR
Abbreviation for “ozone free” technology.
Lamps with the designation OFR do not generate
ozone during operation.
Operating Position
Some lamps are specified/
designed to be operated in certain positions, i.e.,
horizontal or base up.
Ordering Abbreviation
Provides a shorthand
description of the lamp, using a unique code
which can be used when ordering a lamp if the
Product Number is not known. An example would
be: CF15EL/R30/830/MED, which translates to a
15-watt Soft White DULUX®EL reflector electronic
self-ballasted compact fluorescent lamp with an
R30 reflector, 82CRI, 3000K color temperature
and a medium screw base.
PAR Lamps
Pressed aluminized reflector lamp,
with the outer bulb formed from two pressed glass
parts that are fused or sealed together. PAR lamps
may be incandescent, halogen, or HID types.
Parallel vs. Series
Wiring configurations for bal-
lasts. Ballasts with parallel lamp circuitry have the
benefit of companion lamps remaining lit, even if
one of the lamps operated by the ballast should
fail. Systems with series lamp wiring (magnetic
ballasts and many rapid start electronic types)
result in all lamps operated on the ballast going
out if one should fail.
Photo-Optic Specialty Lamps
Photo-Optic
specialty lamps employ a variety of technologies
to meet the very precise levels of performance
required by the entertainment industry, science,
medical and other high-tech fields.
Power
The rate at which energy is taken from
an electrical system or dissipated by a load,
expressed in watts (W); power that is generated by
a utility is typically expressed in volt-amperes (VA).
Power Factor
A measure of the effectiveness
with which an electrical device converts volt-
amperes to watts; devices with power factors
(>0.90) are “high power factor” devices.
Preheat
A class of fluorescents requiring a starter,
which allows the lamp and filaments to be properly
heated before allowing the ballast to supply the
correct current flow.
Product Number
(See NAED.)
Programmed Rapid Start (PS)
A method of
starting fluorescent lamps where cathode heat is
applied prior to lamp ignition, then removed or
reduced once the lamp has ignited. PROStart®
ballasts maximize the number of lamp starting
cycles while maintaining energy efficiency. This is
the preferred mode of lamp starting for applica-
tions with occupancy sensors and several on/off
cycles per day. Additionally, the lamps will strike
reliably in cold conditions down to 0°F.
Rapid Start (RS)
Rapid start ballasts apply
a low filament voltage to preheat the cathodes.
Simultaneously, a starting voltage (lower than that
used in instant start) is also applied to strike the
arc. When the cathodes are hot enough, the lamp
will strike. The filament voltage continues to be
applied throughout the operation of the lamp.
Rapid start ballasts appear to have a slight turn on
delay compared to instant start. They will typically
not be able to start lamps reliably under 50°F.
Reference Ballast
A ballast specially construct-
ed to have certain prescribed characteristics for
use in testing electric-discharge lamps and other
ballasts. Reference ballasts are typically defined by
ANSI.
Reflector
A device used to redirect the light by
the process of reflection. Photo-Optic reflector
lamps utilize ellipsoidal (converging light rays) or
parabolic (collimating light rays) reflectors. Dichroic
coated reflectors are designed to reflect visible light
and pass through unwanted infrared wavelengths.
Resistance (R)
A measure of resistance to flow
of current, expressed in ohms
()
.
Safety
Ballasts should be installed and operated
in compliance with the National Electric Code
(NEC), Underwriters Laboratories Inc. (UL) require-
ments, and all applicable codes and regulations.
Since it is possible to come in contact with poten-
tially hazardous voltages, only qualified personnel
should perform ballast installation. All installation,
inspection, and maintenance of lighting fixtures
should be done with the power to the fixture
turned off.
Shielding
A general term to include all devices
used to block, diffuse or redirect light rays, includ-
ing baffles, louvers, shades, diffusers and lenses.
Single-Ended
Lamps having a single lamp base
or point of electrical connection.
Spectral Power Distribution (SPD)
A curve illustrating the distribution of radiant power
produced by the lamp, at each wavelength across
the spectrum.
Spotlight
A luminaire using halogen/incandescent
or a high intensity discharge (HID) lamp that pro-
duces a narrow beam angle designed to illuminate
a specifically defined area. It can also be called a
reflector lamp.
TCLP Test (Toxicity Characteristic Leaching
Procedure)
Federal EPA regulations (RCRA of
1990) have defined a TCLP test to determine
whether wastes are to be treated as hazardous
or non-hazardous.
Total Harmonic Distortion (THD)
A measure
of the distortion of an electrical wave form.
Excessive THD (defined by ANSI as greater than
32%) may cause adverse effects to the electrical
system. <20% THD ballasts are fine for most
applications. However, in buildings with neutral
problems caused by high THD loads such as
computers, printers, DC supplies, etc., the <10%
THD products can help reduce the overall % of
Total Harmonic Distortion.
Transient Protection
OSRAM SYLVANIA bal-
lasts meet ANSI 62.41 Category A. This helps
ensure immunity to electrical disturbances such as
power line transients, and temporary line voltage
dropouts, surges and sags.
Trigger Start
A circuit used to eliminate the
starter and start the preheat lamp almost instantly.
In this circuit each electrode is connected to a
separate winding in the ballast so that the elec-
trode is continuously heated.
Tungsten Halogen Cycle
A regenerative cycle
of tungsten and halogen atoms, which, when incor-
porated into the design of halogen light sources,
prevents blackening of the lamp envelope during life.
Voltage (V)
A measure of electrical potential,
expressed in volts (V). Voltage is the “force” that
pushes electrical current through a conductor.
Watt (W)
A unit of electrical power equal to 1
joule per second. Lamps are rated in watts to indi-
cate power consumption. Also see Nominal watts.
Wavelength
(λ)
Distance between two succes-
sive points of a periodic wave; the wavelengths of
light are typically expressed in nanometers (nm),
or billionths of a meter.
Working Distance
(See Focal Distance.)
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
1
I
N
C
A
N
D
E
S
C
E
N
T
INCANDESCENT LIGHTING
The incandescent lamp consists of a wire filament on a suitable mount enclosed in a glass bulb containing a gas or a vacuum.
When the lamp is connected to an electrical circuit, the current passing through the wire must overcome the filament’s
resistance, and the power consumed heats the filament to incandescence (causes it to glow).
Incandescent bulbs are still the standard choice when the quality of light really counts. The different shapes, coatings and features provide
a variety of options for many lighting applications. With warm color temperatures and superior color rendering, nothing sets the mood like
incandescent lighting.
THE BEST QUALITY OF LIGHT FOR:
Atmospher
Atmosphere
e
Romance
Romance
W
War
armth
mth
Beauty
Beauty
Comfor
Comfort
t
Elegance
Elegance
Sylvania uses the highest quality components designed to offer superior performance on every lamp.
QUALITY LIGHT
QUALITY CONSTRUCTION
Variety of coatings and
finishes
High performance
base cement
Double coil
and filament support
Fused Lead wires
Lead-free solder
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
2
I
N
C
A
N
D
E
S
C
E
N
T
Double Life
Daylight™
Rough Service
Safeline®
Specialty
LAMP CATEGORIES
Sylvania offers a wide assortment of premium lighting products that add value through superior performance, long life, beautiful light and
rugged durability.
Our long-life line of premium light bulbs
Long Life without compromising brightness and light quality
• Lasts up to twice the life of a regular light bulb with almost the
same light output
• Available in many different shapes and sizes
Our most pleasing light
Unique coating that simulates natural light
• Delivers whiter, more Natural light
• Enhances color performance
Our toughest line of light bulbs
Able to withstand knocks and bumps
• Extra support
• Most durable construction
Our Safest light bulbs
Shatter resistant, weather resistant
• Safely Contains Glass in case of breakage
• Provides Weather Protection
Our complete assortment of specialized light bulbs
Diverse line of light bulbs for specific uses
• Gro-Lux®• Heat Lamps
• Night Lights • Colored Lamps
• Appliance Lamps • Street lighting
Perfect for hard to reach applications
Ideal for applications where lamp may be subject to vibration
The best choice to bring more natural light indoors
Appropriate when safety comes first
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
3
I
N
C
A
N
D
E
S
C
E
N
T
Finishes
W - Soft White
DAY - Daylight™
Y- Yellow
B - Blue
R - Red
G - Green
A- Amber
IC - Iridescent clear
FL - Flood
SP - Spot
IF - Inside frost
BL - Blister
AIC - Amber iridescent
BULB IDENTIFICATION
Light Center Length (L.C.L.) is the distance
from the center of the light source to the fol-
lowing point for the base used: Screw
bases...bottom base contact; Bayonet cande-
labra and medium bayonet...top of base pins;
Medium and Mogul Prefocus...top of base pin;
S.C. or D.C.Prefocus - Plane of locating boss-
es of prefocusing collar.
BASE IDENTIFICATION
Typical bases are shown. One lead-in wire is
soldered to the center contact and the other
soldered or welded to the upper rim of the
base shell. Base shells are typically made of
brass or aluminum. ANSI designations are in
parentheses.
FILAMENT IDENTIFICATION
A FILAMENT designation consists of a prefix
letter to indicate whether the wire is straight or
coiled, and a number to indicate the arrange-
ment of the filament on the supports. Prefix
letters include: C (coiled) --wire is wound into
a helical coil or it may be deeply fluted; CC
(coiled coil)--wire is wound into a helical coil
and this coiled wire again wound into a helical
coil.
ADDITIONAL INFORMATION
Lamps Listed 115-125 volts (design voltage
120), 120-130 volts (design voltage 125),
125-130 volts (design voltage 130) and 230-
250 volts (design voltage 240) are intended
for use on circuits normally varying within
these voltage limits.
Bulb size - Max. Diameter (Divide by 8)
A-21 - 21⁄8 = 2 5⁄8” Dia.
G-40 - 40⁄8 = 5” Dia.
T-12 - 12⁄8 = 1 1⁄2” Dia.
PS-30 - 30⁄8 = 3 3⁄4” Dia.
C-2R
C-8
CC-8
C-11V C-5
C-2V
CC-2V
C-9
CC-9
C-11
CC-11
C-7A
CC-7A
C-6
CC-6
Candelabra
cand. (E12) Intermediate
Inter. (E17)
Mogul End Prong
Ext. Mogul
End Prong GX16d
Medium (E26) &
Medium Brass
(E26)
Double Contact
Bayonet D.C.
Bay (BA15D)
3 Contact
Medium
3 C Med (E26D)
Medium Skirted
Med. Skirt
(E26/50x39)
Mogul Screw S14s Med Side Pr. Screw Terminal
G53
3 Contact Mogul
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
4
I
N
C
A
N
D
E
S
C
E
N
T
INCANDESCENT LAMP SHAPES
A bulb designation consists of a letter(s) to indicate the shape and
a figure(s) to indicate the approximate major diameter in eighths
of in inch. For example, an F-15 bulb is a flame-shape, 15/8 of an
inch or 1-7/8 inches in diameter.
B10 Cand C7 DC BayF15 Med C7 Cand C15 MedB10 Blunt Tip B10 Crystal
A15 Med A19 Med A21 Med A21 3C Med A23 Med
G16.5 Cand G16.5 Med G25 Med G30 Med
S11 DC Bay S11 InterS11 Cand S11 Med S14 Med
T6 Cand
ER30 Med
P25 Med PS25 3C
Mog PS25 Med PS30 Med PS35 Mog
ER40 Med
BR30 Med BR40 Med
R14 Inter R14 Med K19 Med R20 Med
R40 Med
R40 Med Skrt
PAR56 Mog
End Pr
PAR56 Scrw TrmPAR46 Med
Sid Pr PAR64 Scrw Trm PAR64 Ex Mog
End Pr
PAR46 Scrw TrmPAR38 Med
Skrt PAR38 Med
Sid Pr PAR46 Mog
End Pr
R40 Mog
T7 Cand T7 DC Bay T7 Inter T8 Cand T8 DC Bay
T6.5 DC Bay
T6.5 Inter
LINESTRA 2-base
T8 Inter T10 Med
S 19 MedS6 DC BayS6 Cand
G40 Med
R16 Med
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
5
I
N
C
A
N
D
E
S
C
E
N
T
HOW TO READ PRODUCT INFORMATION - INCANDESCENT
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
Bulb Describes the shape of the envelope followed by the lamp’s major diameter given in eighths of an inch.
See page 3: Incandescent Lamps.
Base See page 3: Base Identification.
Symbols & All symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and foot
Footnotes notes are at the end of the incandescent section.
Ordering A text description of the lamp. See below for several examples and explanations of some of the codes.
Abbreviation
Class & The class is either B (vacuum) or C (gas filled). The filament designation describes the shape and mount structure of the filament.
Filament See page 3: Filament Identification.
Lumens, This column may contain data for any of these values. Lumen values are followed by the designation ‘lm’. Beam angles are
Beam Angle, indicated by either a ‘°’ or the designation ‘V x H’ for non-symmetric beams. CBCP values are followed by the designation ‘cd’.
CBCP
HOW TO READ ORDERING ABBREVIATIONS
INCANDESCENT BRAND NAME GUIDE
NOTE: These tables are intended only as a guide and may represent another lamp company’s closest competitive type rather than an identical
match. Individual manufacturers’ performance values should be consulted. Environmental conditions, ballast type, and other auxillary equip-
ment may affect lamp performance.
INCANDESCENT
SYLVANIA GE* PHILIPS**
Bug-Light House Garden - Bug-Lite Bug-A-Way
Double Life Long Life Longer Life
Double Life Soft White Long Life Soft White Longer Life Soft White
DaylightReveal Natural
Energy Saver Soft White Soft White Miser Energy Saving
EXCEL-LINE®Extended Service Extended Service
Linestra®Lumiline Philinea
RHINO COAT®SAFELINE®COV-R-GUARD Silicone Coated
Rough Service Ruff-n-Tuff Rough Service
Rough Service XL Survivor
Soft Pink Soft Pink Pink Softone Pastels
Spot-GRO®House Garden - Plant Light Agro-Lite
SUPERSAVER®Watt-Miser Econo-o-Watt
SUPERSAVER EXCEL-LINE Watt-Miser Plus Extended Service
SUPERSAVER PAR Watt-Miser PAR Econo-o-PAR
*Trademark and or registered trademark of General Electric Company. **Trademark and or registered trademark of Philips.
40B10C/CRYSTAL/DL/BL/2PK
40 Nominal lamp wattage
BBulb shape
10 Bulb size in 8th's of an inch
CCandelabra base
CRYSTAL Crystal texture on bulb glass
DL Double Life Lamp
BL Blister pack
2PK 2 lamps per package
60A/DLSW/2PK/RP
60 Nominal lamp wattage
ABulb shape
DL Double life lamp
SW Soft white
2PK 2 lamps per package
RP Retail pack
65BR30/DL/FL/RP
65 Nominal lamp wattage
BR Bulb shape
30 Bulb size in 8th's of an inch
DL Double life lamp
FL Flood beam pattern
RP Retail pack
A15 A19 G25 R20 A21 BR30 C7 Candelabra B10
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
6
I
N
C
A
N
D
E
S
C
E
N
T
DAYLIGHT™ LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
40 A15 Med 10181 40A15/DAY/FAN/BL/2/24 120 24 Daylight Fan C, C-9 1000 340 lm 23/831/2
A19 Med 11100 40A/DAY/RP/2/24 120 24 Daylight C, CC-8 1500 350 lm 31/847/16
10864 40A/DAY/RP/4/48 120 48 Daylight C, CC-8 1500 350 lm 31/847/16
10897 40A/DAY/4/160/RP 120 160 Daylight C, CC-8 1500 350 lm 31/847/16
G25 Med 13966 40G25/DAY/1/6 120 6 Daylight Globe C, C-9 1500 47/16
14002 40G25/DAY/1/48 120 48 Daylight Globe C, C-9 1500 47/16
50 R20 Med 15231 1,2,3,4 50R20/DAY/1/6/RP 120 6 Daylight Reflector C, C-9 2000 240 lm 315/16
45°
400 cd
50 A21 3CONTACT Med 18110 50/150/DAY/1/12 120 12 Daylight 3-way C, CC-8 1200 490 lm 33/855/16
100 1250 lm
150 1740 lm
18119 50/150/DAY/1/96 120 96 Daylight 3-way C, CC-8 1200 490 lm 33/855/16
1250 lm
1740 lm
60 A19 Med 11101 60A/DAY/RP/2/24 120 24 Daylight C, CC-8 1000 640 lm 31/847/16
11463 60A/DAY/RP/4/48 120 48 Daylight C, CC-8 1000 640 lm 31/847/16
11509 60A/DAY/4/160/RP 120 160 Daylight C, CC-8 1000 640 lm 31/847/16
G25 Med 13967 60G25/DAY/1/6 120 6 Daylight Globe C, C-9 1500 47/16
14003 60G25/DAY/1/48 120 48 Daylight Globe C, C-9 1500 47/16
65 BR30 Med 15223 1,2,4,5 65BR30/DAY/1/6/RP 120 6 Daylight Reflector C, CC-6 2000 420 lm 53/8
60°
250 cd
75 A19 Med 11102 75A/DAY/RP/2/24 120 24 Daylight C, CC-8 750 850 lm 31/847/16
10865 75A/DAY/RP/4/48 120 48 Daylight C, CC-8 750 850 lm 31/847/16
10863 75A/DAY/4/160/RP 120 160 Daylight C, CC-8 750 850 lm 31/847/16
100 A19 Med 12952 100A/DAY/RP/2/24 120 24 Daylight C, CC-8 750 1270 lm 31/847/16
12587 100A/DAY/RP/4/48 120 48 Daylight C, CC-8 750 1270 lm 31/847/16
12948 100A/DAY/4/160/RP 120 160 Daylight C, CC-8 750 1270 lm 31/847/16
DOUBLE LIFE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
4C7 Candelabra 13523 4C7/DL/BL/4PK 120 48 Double Life Night Light B, C-9 6000 14 lm 21/8
15 B10 Candelabra 13315 15B10C/DL/BL 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
25 B10 Candelabra 13306 25B10C/DL/BL/4PK 120 24 Clear Double Life Decor C, C-7A 3000 37/8
Bent Tip
13316 25B10C/DL/BL 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13743 25B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13317 25B10C/DLF/BL 120 12 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13308 25B10C/DLF/BL/4PK 120 24 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
Med 13318 6 25B10/DL/BL 120 12 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
B10 G25 A21 A15 A19 R20
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
7
I
N
C
A
N
D
E
S
C
E
N
T
DOUBLE LIFE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
25 B10 Med 13331 6 25B10/DL/BL/4PK 120 24 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
G25 Med 14145 25G25/DL/RP 120 6 Clear Double Life Globe C, C-9 3000 47/16
14105 25G25/DL/RP/48 120 48 Clear Double Life Globe C, C-9 3000 47/16
14146 25G25/DLSW/RP 120 6 Soft White Double Life C, C-9 3000 47/16
Globe
14103 25G25/DLSW/RP/48 120 48 Soft White Double Life C, C-9 3000 47/16
Globe
30 A21 3CONTACT Med 19380 30/100A21/DLSW/RP 120 12 Soft White Double Life C, CC-8 2400 270 lm 33/855/16
70 3-way 860 lm
100 1130 lm
32 B10 Candelabra 13737 32B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 4000 37/8
Bent Tip
40 A15 Med 10133 40A15/CL/DL/BL 120 12 Clear Double Life C, C-9 2000 350 lm 23/831/2
Appliance
10168 40A15/CL/DL/BL/2/24 120 24 Clear Double Life C, C-9 2000 350 lm 23/831/2
Appliance
10023 40A15/CL/DL/FAN/BL/2/24 120 24 Clear Double Life C, C-9 2000 350 lm 23/831/2
Ceiling Fan Light
10046 40A15/CL/DL/FAN 120 24 Clear Double Life Fan C, C-9 2000 350 lm 23/831/2
Light
A19 Med 10939 40A/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 3000 390 lm 31/847/16
B10 Candelabra 13319 40B10C/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13328 40B10C/DL/BL/4PK 120 24 Clear Double Life Decor C, C-7A 3000 37/8
Bent Tip Four Pack
13741 40B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13714 40B10C/CRYSTAL/DL/BL/4/24 120 24 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13320 40B10C/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13309 40B10C/DLF/BL/4PK 120 24 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
Med 13321 6 40B10/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13740 6 40B10/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 313/16
Bent Tip
13723 6 40B10/CRYSTAL/DL/BL/4PK 120 24 Double Life Crystal C, C-7A 3000 313/16
Bent Tip
13322 6 40B10/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 313/16
Décor Bent Tip
G25 Med 14147 40G25/DL/RP 120 6 Clear Double Life Globe C, C-9 3000 47/16
14174 40G25/DL/1/48 120 48 Clear Double Life Globe C, C-9 3000 47/16
14148 40G25/DLSW/RP 120 6 Soft White Double Life C, C-9 3000 47/16
Globe
14175 40G25/DLSW/1/48 120 48 Soft White Double Life C, C-9 3000 47/16
Globe
50 R20 Med Brass 14943 1,2,3,4 50R20/DL/RP 120 6 Double Life Reflector C, C-9 4000 290 lm 315/16
Flood 45°
480 cd
A21 A15 A19 B10 G25 BR30 BR40
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
8
I
N
C
A
N
D
E
S
C
E
N
T
DOUBLE LIFE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
50 A21 3CONTACT Med 18044 50/150A21/DLSW/RP 120 12 Soft White Double Life C, CC-8 2400 540 lm 33/855/16
100 3-way 1400 lm
150 1940 lm
60 A15 Med 10024 60A15/CL/DL/FAN/BL/2/24 120 24 Clear Double Life Fan C, C-9 2000 530 lm 23/831/2
Light
10048 60A15/CL/DL/FAN/RP 120 24 Clear Double Life Fan C, C-9 2000 530 lm 23/831/2
Light
A19 Med 11260 60A/CL/DL/RP 120 24 Clear Double Life C, CC-8 2000 790 lm 31/847/16
11227 60A/DLSW/2PK/RP 120 24 Soft White Double Life C, CC-8 2000 770 lm 31/847/16
11204 60A/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 2000 770 lm 31/847/16
B10 Candelabra 13777 60B10C/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13705 60B10C/DL/BL/4PK 120 24 Clear Double Life Decor C, C-7A 3000 37/8
Bent Tip Four Pack
13744 60B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13749 60B10C/CRYSTAL/DL/BL/4/24 120 24 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13778 60B10C/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13754 60B10C/DLF/BL/4PK 120 24 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
Med 13323 6 60B10/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13333 6 60B10/DL/BL/4PK 120 24 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13324 6 60B10/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 313/16
Décor Bent Tip
G25 Med 14149 60G25/DL/RP 120 6 Clear Double Life Globe C, C-9 3000 47/16
14106 60G25/DL/RP/48 120 48 Clear Double Life Globe C, C-9 3000 47/16
14150 60G25/DLSW/RP 120 6 Soft White Double Life C, C-9 3000 47/16
Globe
14104 60G25/DLSW/RP/48 120 48 Soft White Double Life C, C-9 3000 47/16
Globe
65 BR30 Med Brass 15177 1,2,4,5 65BR30/DL/FL/RP 120 6 Double Life Reflector C, CC-6 4000 510 lm 53/8
Flood 60°
300 cd
75 A19 Med 11175 75ACL/DL/RP 120 24 Clear Double Life C, CC-8 1500 1055 lm 31/847/16
11337 75A/DLSW/2PK/RP 120 24 Soft White Double Life C, CC-8 1500 1035 lm 31/847/16
11331 75A/W/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 1500 1035 lm 31/847/16
BR40 Med Brass 15144 2,4,5 75BR/DL/FL/RP 120 6 Double Life Reflector C, CC-6 4000 610 lm 61/2
Flood 60°
400 cd
15213 2,4,5 75BR40/DL/FL/1/24 120 24 Double Life Reflector C, CC-6 4000 610 lm 61/2
Flood 60°
400 cd
100 A19 Med 11176 100A/CL/DL/RP 120 24 Clear Double Life C, CC-8 1500 1550 lm 31/847/16
12805 100A/DLSW/2PK/RP 120 24 Soft White Double Life C, CC-8 1500 1530 lm 31/847/16
11332 100A/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 1500 1530 lm 31/847/16
120 BR40 Med 14915 1,2,4,5 120BR/DL/FL/RP 120 6 Double Life Reflector C, CC-6 4000 960 lm 61/2
Flood 60°
835 cd
S6 C7 Candelabra S14 S11
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
9
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
3S6 Candelabra 16759 7 3S6/5 130 240 Clear Indicator B, C-7A 3000 12 lm 17/16 17/8
16757 3S6/5 120 240 Clear Indicator B, C-7A 3000 10 lm 17/16 17/8
4C7 Candelabra 13542 4C7/BL/2PK 120 24 Clear Night Light B, C-9 3000 16 lm 21/8
13549 4C7/BL/4PK 120 48 Clear Night Light B, C-9 3000 16 lm 21/8
13546 4C7/BULK 120 250 Clear Night Light B, C-9 3000 16 lm 21/8
13523 4C7/DL/BL/4PK 120 48 Double Life Night Light B, C-9 6000 14 lm 21/8
13538 4C7/W/BL/2PK 120 24 White Night Light B, C-9 3000 16 lm 21/8
13553 4C7/W/BL/4PK 120 48 White Night Light B, C-7 3000 16 lm 21/8
13556 4C7/BLUE/2PK 120 24 Blue Nightlight B, C-7A 3000 21/8
13557 4C7/PINK/2PK 120 24 Pink Nightlight B, C-7A 3000 21/8
6S6 Candelabra 16929 6S6/CL24V 24 120 Clear Indicator B, C-7A 1500 48 lm 17/16 17/8
16927 6S6/CL12V 12 120 Clear Indicator B, C-2R 1500 47 lm 17/16 17/8
16930 6S6/CL30V 30 120 Clear Casino B, C-7A 1500 46 lm 17/16 17/8
16962 6S6/CL/BL 120 24 Clear Indicator B, C-7A 1500 41 lm 17/16 17/8
16960 6S6/CL 120 120 Clear Indicator B, C-7A 1500 41 lm 17/16 17/8
16938 6S6/CL 130 120 Clear Indicator B, C-7A 1500 37 lm 17/16 17/8
16943 6S6/CL155V 155 120 Clear Indicator B, C-7A 1500 36 lm 17/16 17/8
16942 6S6/CL145V 145 120 Clear Indicator B, C-7A 1500 33 lm 17/16 17/8
DC Bayonet 16782 6S6DC 120 120 Clear Indicator B, C-9 1500 41 lm 17/16 113/16
16784 6S6DC 130 120 Clear Indicator B, C-9 1500 37 lm 17/16 113/16
16790 6S6DC145V 145 120 Clear Indicator B, C-9 1500 37 lm 17/16 113/18
S14 Med Brass 17314 6S14 120 120 Clear B, C-9 1500 40 lm 21/231/2
7C7 Candelabra 13543 7C7/BL/2PK 120 24 Clear Night Light B, C-9 3000 43 lm 21/8
13545 7C7/BL/4PK 120 48 Clear Night Light B, C-9 3000 43 lm 21/8
13608 7C7 120 120 Clear Night Light B, C-9 3000 43 lm 21/8
13609 7C7 130 120 Clear Night Light B, C-9 3000 42 lm 21/8
13540 7C7/W/BL/2PK 120 24 White Night Light B, C-9 3000 33 lm 21/8
13544 7C7/W/BL/4PK 120 48 White Night Light B, C-9 3000 33 lm 21/8
13623 7C7/CW 120 120 White Night Light B, C-9 3000 33 lm 21/8
13629 7C7/O 120 120 Orange Nightlight B, C-9 3000 21/8
13626 7C7/R 120 120 Red Night Light B, C-9 3000 21/8
8S11 Med 19353 7.5S 120 120 Clear B, C-9 1400 47 lm 19/16 21/4
19355 7.5S 130 120 Clear B, C-9 1400 45 lm 19/16 21/4
19433 7.5S/CW/BL 120 12 Ceramic White Utility B, C-9 1400 32 lm 21/4
Light
19420 7.5S/CW 120 120 Ceramic White B, C-9 1400 32 lm 21/4
19424 7.5S/CR/BL 120 12 Ceramic Red B, C-9 1400 21/4
19423 7.5S/CR 120 120 Ceramic Red B, C-9 1400 21/4
10 C7 Candelabra 13636 8 10C7/CL 120 240 Clear Pilot Light B, C-7A 38 lm 21/8
Ruggedized
DC Bayonet 13527 8 10C7/DC 120 120 Clear Pilot Light B, C-7A 38 lm 21/8
Ruggedized
S6 Candelabra 16726 10S6 120 240 Clear Indicator B, C-7A 1500 71 lm 17/16 17/8
S6 S11 S14 A15 T7 T10 A21 T6.5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
10
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
10 S6 Candelabra 16717 7 10S6230V 230 240 Clear Indicator B, CC-7A 1500 65 lm 17/16 17/8
S11 Candelabra 17025 10S11/79 120 120 Clear B, C-7A 1500 78 lm 19/16 21/4
Intermediate 16917 10S11N/CL 120 120 Clear Ruggedized B, C-7A 1500 74 lm 15/825/16
16919 10S11N/CL 130 120 Clear Ruggedized B, C-7A 1500 74 lm 15/825/16
S14 Med Brass 17406 10S14 120 120 Clear Ruggedized B, C-9 1500 76 lm 21/231/2
17424 10S14/IF 120 120 Inside Frost Ruggedized B, C-9 1500 76 lm 21/231/2
11 S14 Med Brass 17448 11S14 120 120 Clear Ruggedized B, C-9 3000 74 lm 21/231/2
17450 11S14 130 120 Clear Ruggedized B, C-9 3000 72 lm 21/231/2
17453 11S14/IF 130 120 Inside Frost Ruggedized B, C-9 3000 68 lm 21/231/2
17489 11S14/TB 130 120 Transparent Blue B, C-9 3000 21/231/2
17490 11S14/TG 130 120 Transparent Green B, C-9 3000 21/231/2
17487 11S14/TR 130 120 Transparent Red B, C-9 3000 21/231/2
17488 11S14/TY 130 120 Transparent Yellow B, C-9 3000 21/231/2
12 S6 Candelabra 16718 12S6250V 250 240 Clear Indicator B, CC-7A 1500 61 lm 17/16 17/8
15 A15 Med 10028 15A15/CL/RP 120 24 Clear Utility Light B, C-9 2500 105 lm 23/831/2
10018 15A15/CL 120 120 Clear Utility Light B, C-9 2500 105 lm 23/831/2
10019 15A15/CL 130 120 Clear Utility Light B, C-9 2500 105 lm 23/831/2
10031 15A15/RP 120 24 Inside Frost B, C-9 2500 100 lm 23/831/2
10037 15A15 120 120 Inside Frost B, C-9 2500 100 lm 23/831/2
10038 15A15 130 120 Inside Frost B, C-9 2500 100 lm 23/831/2
10015 15A15/W/RP 120 24 White Utility Light C, C-9 2500 65 lm 23/831/2
Med Brass 10083 15A15/CL 30 120 Clear B, C-9 1000 156 lm 23/831/2
10101 15A15/BB/IF/PLT 130 12960 Inside Frost B, C-9 2500 100 lm 23/831/2
11502 15A15/R 120 120 Red Utility Light B, C-9 2500 23/831/2
S11 Med 17080 15S11/102/CL 120 120 Clear Refrigerator B, C-7A 400 138 lm 19/16 21/4
17079 15S11/102/IF 120 120 Inside Frost B, C-7A 400 138 lm 19/16 21/4
Refrigerator
S14 Med Brass 17240 15S14/CL 130 120 Clear Ruggedized Sign B, C-9 3000 106 lm 21/231/2
T6 Candelabra 18036 15T6/BL 145 12 Clear Tubular B, C-7A 2000 112 lm 31/16
18078 15T6145V 145 60 Clear Tubular B, C-7A 2000 112 lm 31/16
18037 15T6 120 60 Clear Tubular B, C-7A 2000 111 lm 31/16
18038 15T6 130 60 Clear Tubular B, C-7A 2000 105 lm 31/16
T7 Candelabra 18185 15T7C 120 60 Clear B, C-7A 1000 111 lm 11/221/4
DC Bayonet 18200 9 15T7DC/BL 120 12 Clear Carded B, C-7A 1000 111 lm 15/16 21/4
18208 9 15T7DC 120 60 Clear B, C-7A 1000 111 lm 15/16 21/4
Intermediate 18174 9 15T7N/BL 120 12 Clear B, C-7A 1000 115 lm 19/16 21/4
18173 9 15T7N 120 60 Clear B, C-7A 1000 115 lm 19/16 21/4
T10 Med 18501 7 15T10/CL 120 60 Clear Tubular B, C-8 2500 112 lm 55/8
15 A21 3CONTACT Med 18009 15/150A/SECURITYLIGHT 120 12 Soft White Security C, CC-8 1200 80 lm 33/855/16
135 3-way 2070 lm
150 2150 lm
20 T6.5 DC Bayonet 18144 8 20T6.5DC/IF 120 60 Inside Frost Exit Lamp B, C-8 10000 92 lm 59/16
Intermediate 18143 8 20T6.5/IF 120 60 Inside Frost Exit Lamp B, C-8 10000 92 lm 51/2
A15 A19 R14 T6.5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
11
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
25 A15 Med Brass 10120 25A15/BR 120 120 Inside Frost B, C-9 1100 210 lm 23/831/2
10139 25A15/RFL 130 120 Reflector Sign B, C-9 2500 168 lm 23/831/2
A19 Med 11090 25A/RS 120 120 Inside Frost Rough B, C-17 1000 210 lm 21/2315/16
Service
11092 25A/RS 130 120 Inside Frost Rough B, C-17 1000 210 lm 21/2315/16
Service
11285 25A 230 120 Standard Frost B, C-17 1000 205 lm 21/2315/16
10634 25A/RP 120 24 Standard Frost B, C-9 2500 190 lm 21/2315/16
10644 25A 120 120 Standard Frost B, C-9 2500 190 lm 21/2315/16
11289 25A 277 120 Standard Frost B, C-17 1000 187 lm 21/2315/16
10645 11 25A 130 120 Standard Frost B, C-9 2500 180 lm 21/2315/16
@120 volts, approximate 22 watts, 130 lumens, 6250 hours
10562 25A/W/RP 120 24 Soft White C, C-9 2500 160 lm 21/2315/16
Med Brass 10683 25A/CL/RP 120 24 Clear B, C-9 2500 190 lm 21/2315/16
10693 25A/CL 120 120 Clear B, C-9 2500 190 lm 21/2315/16
10738 25A19/CL/GR 130 120 Clear Sign Group B, C-9 3000 185 lm 21/2315/16
Replacement
10694 11 25A/CL 130 120 Clear B, C-9 2500 180 lm 21/2315/16
@120 volts, approximate 22 watts, 130 lumens, 6250 hours
10449 25A 12 120 Standard Frost B, C-6 1000 385 lm 21/2315/16
10734 25A19/IF/GR 130 120 Inside Frost Group B, C-9 3000 185 lm 21/2315/16
Replacement
11710 25A19/TB/RP 125 6 Transparent Blue B, C-9 3000 21/2315/16
11430 25A/B/RP 120 6 Blue B, C-9 2500 21/2315/16
11356 25A/B 120 120 Blue B, C-9 2500 21/2315/16
11714 25A19/TG/RP 125 6 Transparent Green B, C-9 3000 21/2315/16
11431 25A/G/RP 120 6 Green B, C-9 2500 21/2315/16
11359 25A/G 120 120 Green B, C-9 2500 21/2315/16
11711 25A19/TO/RP 125 6 Transparent Orange B, C-9 3000 21/2315/16
11432 25A/O/RP 120 6 Orange B, C-9 2500 21/2315/16
11362 25A/O 120 120 Orange B, C-9 2500 21/2315/16
11712 25A19/TR/RP 125 6 Transparent Red B, C-9 3000 21/2315/16
11429 25A/R/RP 120 6 Red B, C-9 2500 21/2315/16
11350 25A/R 120 120 Red B, C-9 2500 21/2315/16
11713 25A19/TY/RP 125 6 Transparent Yellow B, C-9 3000 21/2315/16
11427 25A/Y/RP 120 6 Yellow B, C-9 2500 21/2315/16
11348 25A/Y 120 120 Yellow B, C-9 2500 21/2315/16
R14 Intermediate 14784 25R14N/RP 120 6 Reflector Mini Flood B, CC-2V 1500 29/16
14793 25R14N 120 60 Reflector Mini Flood B, CC-2V 1500 29/16
Med 14818 25R14/RP 120 6 Reflector Mini Flood C, CC-2V 1500 21/4
T6.5 DC Bayonet 18129 25T6.5/DC 120 60 Clear Scale Illuminator B, C-8 1000 242 lm 59/16
18106 25T6.5/DC 130 60 Clear Scale Illuminator B, C-8 1000 242 lm 59/16
18117 25T6.5/DC/IF 120 60 Inside Frost Scale B, C-8 1000 225 lm 59/16
Illuminator
Intermediate 18495 25T6.5/BL/6PK 120 6 Clear B, C-8 1000 242 lm 51/2
T6.5 T8 T10 A15 R20 S11 A21 A19
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
12
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
25 T6.5 Intermediate 18125 25T6.5 120 60 Clear B, C-8 1000 242 lm 51/2
18128 25T6.5 130 60 Clear B, C-8 1000 242 lm 51/2
18113 25T6.5/IF 120 60 Inside Frost B, C-8 1000 225 lm 51/2
18111 25T6.5/IF 130 60 Inside Frost B, C-8 1000 225 lm 51/2
T8 Candelabra 18290 9 25T8C/BL/1/12 120 12 Clear Home Appliance B, C-7A 1000 230 lm 11/225/8
18289 9 25T8C 120 60 Clear Home Appliance B, C-7A 1000 230 lm 11/225/8
DC Bayonet 18321 9 25T8DC/BL 120 12 Clear Home Appliance B, C-7A 1000 230 lm 15/16 25/8
18310 9 25T8DC 120 60 Clear Home Appliance B, C-7A 1000 230 lm 15/16 25/8
18316 9 25T8DC 130 60 Clear Home Appliance B, C-7A 1000 215 lm 15/16 25/8
Intermediate 18365 9 25T8N/BL 120 12 Clear Home Appliance B, C-7A 1000 230 lm 15/16 25/8
18359 9 25T8N 120 60 Clear Home Appliance B, C-7A 1000 230 lm 15/16 25/8
T10 Med 18491 25T10/CL/BL/6PK 120 6 Clear B, C-8 1000 232 lm 55/8
18510 25T10 120 60 Clear B, C-8 1000 232 lm 55/8
18512 25T10 130 60 Clear B, C-8 1000 232 lm 55/8
18492 25T10/IF/BL/6PK 120 6 Inside Frost B, C-8 1000 230 lm 55/8
18503 25T10/IF 120 60 Inside Frost B, C-8 1000 230 lm 55/8
18505 25T10/IF 130 60 Inside Frost B, C-8 1000 230 lm 55/8
Med Brass 18507 25T10/BB/277V 277 60 Clear Exit Light B, C-17 5000 150 lm 55/8
30 A15 Med Brass 10122 30A15 130 120 Inside Frost C, C-9 2000 200 lm 23/831/2
@ 120 volts, approximate 26 watts, 150 lumens, 5000 hours.
R20 Med Brass 14836 3,12 30R20/RP 120 6 Reflector Flood C, C-9 2000 140 lm 315/16
40°
14794 3,12 30R20 120 60 Reflector Flood C, C-9 2000 140 lm 315/16
40°
14802 11 30R20 130 60 Reflector Flood C, C-9 2000 140 lm 315/16
40°
@ 120 volts, approximate 26 watts, 100 lumens, 5000 hours
S11 DC Bayonet 10765 30S11DC75V 75 120 Clear Train Marker C, C-7A 500 284 lm 11/223/8
30 A21 3CONTACT Med 19380 30/100A21/DLSW/RP 120 12 Soft White Double Life C, CC-8 2400 270 lm 33/855/16
70 3-way 860 lm
100 1130 lm
19385 12 30/100A21/W/RP 120 12 Soft White 3-way C, CC-8 1200 300 lm 33/855/16
945 lm
1245 lm
18029 12 30/100A/W/DIYPACK 120 48 Soft White 3-way C, CC-8 1200 300 lm 33/855/16
945 lm
1245 lm
32 A19 Med Brass 10983 32A19/49 130 120 Clear Street Lighting C, C-9 3000 258 lm 27/841/4
Group Replacement
@ 120 volts, approximate 28 watts, 200 lumens, 7500 hours.
34 A19 Med 11379 11 40A/34/SS 130 48 Standard Frost C, CC-8 1500 380 lm 31/847/16
SuperSaver
@ 120 volts, approximate 30 watts, 290 lumens, 3750 hours
11058 40A/34/SS 120 48 Standard Frost C, CC-8 1500 375 lm 31/847/16
SuperSaver
11391 40A/34/W/ES/4PK 120 48 Soft White Energy Saver C, CC-8 1500 375 lm 31/847/16
Med Brass 11383 40A/34/SS/XL 120 48 Standard Frost C, CC-8 2500 310 lm 31/847/16
SuperSaver XL
A19 A15
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
13
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
34 A19 Med Brass 11387 11 40A/34/SS/XL 130 48 Standard Frost C, CC-8 2500 310 lm 31/847/16
SuperSaver XL
@ 120 volts, approximate 30 watts, 240 lumens, 6250 hours
40 A15 Med 10181 40A15/DAY/FAN/BL/2/24 120 24 Daylight Fan C, C-9 1000 340 lm 23/831/2
10133 40A15/CL/DL/BL 120 12 Clear Double Life C, C-9 2000 350 lm 23/831/2
Appliance
10168 40A15/CL/DL/BL/2/24 120 24 Clear Double Life C, C-9 2000 350 lm 23/831/2
Appliance
10046 40A15/CL/DL/FAN 120 24 Clear Double Life Fan C, C-9 2000 350 lm 23/831/2
Light
10023 40A15/CL/DL/FAN/BL/2/24 120 24 Clear Double Life C, C-9 2000 350 lm 23/831/2
Ceiling Fan Light
10082 40A15/SL 120 120 Safeline Appliance C, C-9 1000 420 lm 23/831/2
10129 40A15/CL/BL 120 12 Clear Appliance C, C-9 1000 430 lm 23/831/2
10141 40A15/2PK/RP 120 24 Clear Appliance C, C-9 1000 430 lm 23/831/2
10169 40A15/CL/BL/2/24 120 24 Clear Appliance C, C-9 1000 430 lm 23/831/2
10042 40A15/CL/FAN 120 24 Clear Ceiling Fan Light C, C-9 1000 430 lm 23/831/2
10022 40A15/CL/FAN/BL/2/24 120 24 Clear Ceiling Fan Light C, C-9 1000 430 lm 23/831/2
10117 40A15/IF/BL 120 12 Inside Frost Appliance C, C-9 1000 420 lm 23/831/2
10119 40A15 120 120 Inside Frost Appliance C, C-9 1000 420 lm 23/831/2
10127 40A15/PLT 120 12960 Inside Frost Appliance C, C-9 1000 420 lm 23/831/2
11111 40A15/SW/FAN/BL/2/24 120 24 Soft White Ceiling Fan C, C-9 1000 405 lm 23/831/2
Light
Med Brass 10112 40A15/22 120 120 Clear Range Oven C, C-9 1000 430 lm 23/84
10115 40A15/PLT12960 120 12960 Inside Frost Appliance C, C-9 1000 420 lm 23/831/2
10114 40A15/PLT12960 130 12960 Inside Frost Appliance C, C-9 1000 405 lm 23/831/2
10365 40A15/1 250 120 Inside Frost Appliance B, C 1000 330 lm 21/231/2
A19 Med 11100 40A/DAY/RP/2/24 120 24 Daylight C, CC-8 1500 350 lm 31/847/16
10864 40A/DAY/RP/4/48 120 48 Daylight C, CC-8 1500 350 lm 31/847/16
10897 40A/DAY/4/160/RP 120 160 Daylight C, CC-8 1500 350 lm 31/847/16
10939 40A/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 3000 390 lm 31/847/16
10938 40A/DLSW/4/144/RP 120 144 Soft White Double Life C, CC-8 3000 390 lm 31/847/16
11223 40A/CL/RP 120 24 Clear C, CC-8 1500 480 lm 31/847/16
11036 11 40A/CL 130 120 Clear C, CC-8 1500 460 lm 31/847/16
@ 120 volts, approximate 35 watts, 350 lumens, 3750 hours
10977 40A/W/RP 120 24 Soft White C, CC-8 1500 465 lm 31/847/16
10996 40A/W/4/RP 120 48 Soft White C, CC-8 1500 465 lm 31/847/16
10944 40A/W/4/144/RP 120 144 Soft White C, CC-8 1500 465 lm 31/847/16
11010 40A/RP 120 24 Standard Frost C, CC-8 1500 470 lm 31/847/16
11060 40A/4/RP 120 48 Standard Frost C, CC-8 1500 470 lm 31/847/16
11011 11 40A/CVP 130 24 Standard Frost C, CC-8 1500 460 lm 31/847/16
@ 120 volts, approximate 35 watts, 350 lumens, 3750 hours
11059 11 40A 130 48 Standard Frost C, CC-8 1500 460 lm 31/847/16
@ 120 volts, approximate 35 watts, 350 lumens, 3750 hours
Med Brass 11053 11 40A/CL/99/XL 130 120 Clear Excel-Line SS C, CC-8 2500 420 lm 31/847/16
@ 120 volts, approximate 35 watts, 320 lumens, 6250 hours
K19, R14 S11 T6.5 T10 BR30 A21 A19 ER30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
14
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
40 K19 Med 10471 40K19/DR 120 24 Inside Frost C, CC-6 1150 385 lm 41/8
Directional Reflector
R14 Intermediate 14820 40R14N/RP 120 6 Reflector Mini Flood C, CC-2V 1500 29/16
Med 14819 40R14/RP 120 6 Reflector Mini Flood C, C-9 1500 21/4
R16 Med 14821 40R16/FL/RP 120 6 Reflector Mini Flood C, C-9 1500 37/8
S11 Intermediate 13607 40S11N/BL 120 12 Clear Hi Intensity C, C-7A 500 440 lm 15/825/16
13644 40S11N/BL/2/12 120 12 Clear Hi Intensity C, C-7A 500 440 lm 15/825/16
13595 40S11N 120 120 Clear Hi Intensity C, C-7A 500 440 lm 15/825/16
13600 40S11N/CL/BULK 120 500 Clear Hi Intensity C, C-7A 500 440 lm 15/825/16
T6.5 Intermediate 18152 40T6.5/CL/BL/6PK 120 6 Clear Appliance C, C-8 1000 365 lm 51/2
18096 13 40T6.5/2 120 60 Clear Appliance C, C-8 1000 365 lm 51/2
T10 Med 18493 40T10/CL/BL/6PK 120 6 Clear B, C-8 1000 420 lm 55/8
18650 40T10 120 60 Clear B, C-8 1000 420 lm 55/8
18652 40T10 130 60 Clear B, C-8 1000 420 lm 55/8
18494 40T10/IF/BL/6PK 120 6 Inside Frost B, C-8 1000 415 lm 55/8
18664 40T10/IF 120 60 Inside Frost B, C-8 1000 415 lm 55/8
18669 40T10/IF 130 60 Inside Frost B, C-8 1000 415 lm 55/8
18656 40T10/AQUARIUM/RP 120 6 Aquarium B, C-8 1000 55/8
45 BR30 Med 15103 1,2,4,5 45BR30/FL/RP 120 6 Reflector Flood C, CC-6 2000 350 lm 53/8
60°
170 cd
45 A21 3CONTACT Med 18048 45/140A21/W/ES/RP 120 12 Soft White 3-way Energy C, CC-8 1200 540 lm 33/855/16
95 Saver 1300 lm
140 1840 lm
50 A19 Med 14072 50A/RS 130 24 Inside Frost Rough C, C-9 1000 510 lm 21/2315/16
Service
14070 50A/RS/2/RP 120 24 1000 510 lm
11096 50A/RS/4/144/RP 120 144 1000 510 lm
11393 50A/RS 250 120 Inside Frost Rough C, C-22 1000 450 lm 21/247/16
Service
11397 50A 250 120 Inside Frost B, CC-7A 1000 490 lm 21/247/16
11428 50A 277 120 Inside Frost B, CC-7A 1000 475 lm 21/247/16
Med Brass 11067 14 50A19/RS/CL 75 120 Clear Rough Service C, C-9 1000 505 lm 21/2315/16
Train
11068 14 50A19/RS 75 120 Inside Frost Rough C, C-9 1000 505 lm 21/2315/16
Service Train
11118 15 50A/RS/SL 120 120 Safeline Rough Service C, C-9 1000 490 lm 21/2315/16
A21 Med Brass 11567 50A21/RP 12 12 Inside Frost RV-Marine C, C-6 1000 865 lm 37/8415/16
11572 50A21 12 24 Inside Frost RV-Marine C, C-6 1000 865 lm 37/8415/16
11603 50A21 34 12 Inside Frost Train C, C-9 1000 800 lm 37/16 415/16
ER30 Med 15110 1,4 50ER30/RP 120 6 Elliptical Reflector C, CC-6 2000 350 lm 63/8
Flood 30°
800 cd
15102 1,4 50ER30 120 24 Elliptical Reflector C, CC-6 2000 350 lm 63/8
Flood 30°
800 cd
15107 1,4,11 50ER30 130 24 Elliptical Reflector C, CC-6 2000 320 lm 63/8
Flood 30°
730 cd
@ 120 volts, approximate 44 watts, 240 lumens, 5000 hours
R20 A21 A19
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
15
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
50 R20 Med 15231 1,2,3,4 50R20/DAY/1/6/RP 120 6 Daylight Reflector C, C-9 2000 240 lm 315/16
45°
400 cd
14844 1,2,3,4,11 50R20/CVP 130 6 Reflector Flood C, C-9 2000 330 lm 315/16
45°
550 cd
@ 120 volts, approximate 44 watts, 250 lumens, 5000 hours
14833 1,2,3,4 50R20/RP 120 6 Reflector Flood C, C-9 2000 330 lm 315/16
45°
550 cd
14914 1,2,3,4 50R20/2PK 120 48 Reflector Flood C, C-9 2000 330 lm 315/16
45°
550 cd
14831 1,2,3,4 50R20 120 60 Reflector Flood C, C-9 2000 330 lm 315/16
45°
550 cd
14832 1,2,3,4,11 50R20 130 60 Reflector Flood C, C-9 2000 330 lm 315/16
45°
550 cd
@ 120 volts, approximate 44 watts, 250 lumens, 5000 hours
14846 1,2,3,4,11 50R20/PINK 130 60 Pink Reflector C, C-9 2000 315/16
Med Brass 14943 1,2,3,4 50R20/DL/RP 120 6 Double Life Reflector C, C-9 4000 290 lm 315/16
Flood 45°
480 cd
14834 1,2,3,4 50R20/PINK 120 60 Pink Reflector C, C-9 2000 315/16
14842 1,2,3,4 50R20/GRO 120 6 Spot-GRO Reflector C, C-9 2000 315/16
50 A21 3CONTACT Med 18110 50/150/DAY/1/12 120 12 Daylight 3-way C, CC-8 1200 490 lm 33/855/16
100 1250 lm
150 1740 lm
18119 50/150/DAY/1/96 120 96 Daylight 3-way C, CC-8 1200 490 lm 33/855/16
1250 lm
1740 lm
18044 50/150A21/DLSW/RP 120 12 Soft White Double Life C, CC-8 2400 540 lm 33/855/16
3-way 1400 lm
1940 lm
18060 50/150A21/W/RP 120 12 Soft White 3-way C, CC-8 1200 640 lm 33/855/16
1570 lm
2210 lm
18028 50/150A/W/DIYPACK 120 48 Soft White 3-way C, CC-8 1200 640 lm 33/855/16
1570 lm
2210 lm
18726 50/150A21/SPK/RP 120 12 Soft Pink 3-way C, CC-8 1200 33/855/16
50 A21 3CONTACT Med 19404 50/250A21/W/RP 120 12 Soft White Reading C, CC-8 1200 640 lm 33/855/16
200 Light 3-way 3300 lm
250 3940 lm
19403 50/250A21/2PK 120 96 Soft White Reading C, CC-8 1200 640 lm 33/855/16
Light 3-way 3300 lm
3940 lm
52 A19 Med 11376 60A/52/SS 120 48 Standard Frost C, CC-8 1000 750 lm 31/847/16
SuperSaver
11380 11 60A/52/SS 130 48 Standard Frost C, CC-8 1000 710 lm 31/847/16
SuperSaver
@ 120 volts, approximate 46 watts, 540 lumens, 2500 hours
11392 60A/52/W/ES/4PK 120 48 Soft White Energy Saver C, CC-8 1000 715 lm 31/847/16
A19 A15
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
16
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
52 A19 Med Brass 11384 60A/52/SS/XL 120 48 Standard SuperSaver XL C, CC-8 2500 620 lm 31/847/16
11388 11 60A/52/SS/XL 130 48 Standard SuperSaver XL C, CC-8 2500 610 lm 31/847/16
@ 120 volts, approximate 46 watts, 460 lumens, 6250 hours
58 A19 Med Brass 11150 58A19/62 125 120 Clear Street Lighting C, C-9 3000 650 lm 27/841/4
Group Replacement
11149 58A19/62 120 120 Clear Street Lighting C, C-9 3000 630 lm 27/841/4
Group Replacement
60 A15 Med 10024 60A15/CL/DL/FAN/BL/2/24 120 24 Clear Double Life Fan C, C-9 2000 530 lm 23/831/2
Light
10048 60A15/CL/DL/FAN/RP 120 24 Clear Double Life Fan C, C-9 2000 530 lm 23/831/2
Light
10841 60A15/CL/FAN/BL/2/24 120 24 Clear Ceiling Fan Light C, C-9 1000 700 lm 23/831/2
11007 60A15/CL/FAN/RP 120 24 Clear Ceiling Fan Light C, C-9 1000 700 lm 23/831/2
11005 60A15/SW/FAN/2PK 120 24 Soft White Ceiling Fan C, C-9 1000 680 lm 23/831/2
10842 60A15/SW/FAN/BL/2/24 120 24 Soft White Ceiling Fan C, C-9 1000 680 lm 23/831/2
Med Brass 10843 60A15/GARAGE/BL/2/24 120 24 Inside Frost Garage C, C-9 1000 690 lm 23/831/2
Door Lamp
11008 60A15/GARAGE/RP 120 24 Inside Frost Garage C, C-9 1000 690 lm 23/831/2
Door
10152 60A15/FR/PLT12960 120 12960 Inside Frost C, C-9 1000 690 lm 23/831/2
A19 Med 11101 60A/DAY/RP/2/24 120 24 Daylight C, CC-8 1000 640 lm 31/847/16
11463 60A/DAY/RP/4/48 120 48 Daylight C, CC-8 1000 640 lm 31/847/16
11509 60A/DAY/4/160/RP 120 160 Daylight C, CC-8 1000 640 lm 31/847/16
11260 60A/CL/DL/RP 120 24 Clear Double Life C, CC-8 2000 790 lm 31/847/16
11227 60A/DLSW/2PK/RP 120 24 Soft White Double Life C, CC-8 2000 770 lm 31/847/16
11204 60A/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 2000 770 lm 31/847/16
11201 60A/W/DLSW/4/144/RP 120 144 Soft White Double Life C, CC-8 2000 770 lm 31/847/16
12423 60A/CL/RS/2/RP 120 24 Clear Rough Service C, C-9 1000 555 lm 27/847/16
12977 60A/RS/RP/1 120 12 Inside Frost Rough C, C-9 1000 555 lm 27/847/16
Service
13000 60A/RS/2/RP 120 24 Inside Frost Rough C, C-9 1000 555 lm 27/847/16
Service
12420 11 60A/RS/2/RP 130 24 Inside Frost Rough C, C-9 1000 555 lm 27/847/16
Service
@ 120 volts, approximate 53 watts, 420 lumens, 2500 hours
10503 60A/RS/SL/RP 120 12 Safeline Rough Service C, C-9 1000 555 lm 31/847/16
Inside Frost
11224 60A/CL/RP 120 24 Clear C, CC-8 1000 880 lm 31/847/16
10553 60A/CL 120 120 Clear C, CC-8 1000 880 lm 31/847/16
10558 60A/CL/CVP 130 24 Clear C, CC-8 1000 855 lm 31/847/16
@ 120 volts, approximate 53 watts, 650 lumens, 2500 hours
10555 11 60A/CL 130 120 Clear C, CC-8 1000 855 lm 31/847/16
@ 120 volts, approximate 53 watts, 650 lumens, 2500 hours
11208 60A/W/RP 120 24 Soft White C, CC-8 1000 850 lm 31/847/16
11205 60A/W/4/RP 120 48 Soft White C, CC-8 1000 850 lm 31/847/16
11200 60A/W/4/144/RP 120 144 Soft White C, CC-8 1000 850 lm 31/847/16
11214 60A/RP 120 24 Standard Frost C, CC-8 1000 870 lm 31/847/16
A19 C15 K19 PAR46 T10 BR30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
17
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
60 A19 Med 11180 60A/4/RP 120 48 Standard Frost C, CC-8 1000 870 lm 31/847/16
10489 11 60A/CVP 130 24 Standard Frost C, CC-8 1000 855 lm 31/847/16
@ 120 volts, approximate 53 watts, 650 lumens, 2500 hours
11373 11 60A 130 48 Standard Frost C, CC-8 1000 855 lm 31/847/16
@ 120 volts, approximate 53 watts, 650 lumens, 2500 hours
11715 60A/BLACKLIGHT/RP 120 6 Blacklight C, CC-8 1000 31/847/16
10576 60A/SPK 120 24 Soft Pink C, CC-8 1000 31/847/16
12280 60A/GRO 120 6 Spot-GRO C, C-9 1000 31/847/16
10390 60A/Y/RP 120 24 Yellow Bug Light C, CC-8 1000 31/847/16
10386 60A/Y/RP 130 24 Yellow Bug Light C, CC-8 1000 31/847/16
Med Brass 12455 60A/RS/XL 130 24 Inside Frost Rough C, C-9 5000 450 lm 27/847/16
Service XL
@ 120 volts, approximate 53 watts, 340 lumens, 12500 hours.
10640 60A 24 120 Inside Frost Dental C, C-9 1000 1010 lm 31/847/16
Spot
C15 Med Brass 14200 60C15/FAN/2PK 120 12 Clear Ceiling Fan Light C, C-9 4000 528 lm 41/2
K19 Med 10483 60K19/DR 120 24 Inside Frost C, CC-6 1150 630 lm 41/8
Directional Reflector
10485 60K19/DR/2PK 120 48 Inside Frost C, CC-6 1150 630 lm 41/8
Directional Reflector
PAR46 Screw Term 15199 5,16 60PAR46 38 12 Locomotive Headlamp C, CC-2V 800 33/4
15201 5,16 60PAR46/R 38 12 Red Train Warning C, CC-2V 800 33/4
S19 Med Brass 18513 60S19/CL/LANDMARK 120 12 Clear Landmark C, C-9 10000 520 lm 31/847/16
18516 60S19/LANDMARK 120 12 Inside Frost Landmark C, C-9 10000 480 lm 31/847/16
T10 Med 18710 60T10/64 120 60 Clear C, C-8 1000 655 lm 55/8
18711 60T10/CF 120 60 Inside Frost Showcase C, C-8 1000 630 lm 55/8
S14S 19675 LN60 125 25 Opal White LINESTRA B, C-8 1000 460 lm 1911/16
1605
65 BR30 Med 15223 1,2,4,5 65BR30/DAY/1/6/RP 120 6 Daylight Reflector C, CC-6 2000 420 lm 53/8
60°
250 cd
15167 1,2,4,5 65BR30/FL/SL/RP 130 6 Reflector Safeline C, CC-6 2000 620 lm 53/8
Flood 60°
370 cd
15149 1,2,4,5 65BR30/SP/RP 120 6 Reflector Spot C, CC-6 2000 620 lm 53/8
30°
580 cd
15172 1,2,4,5 65BR30/FL/CVP 130 6 Reflector Flood C, CC-6 2000 620 lm 53/8
60°
370 cd
15160 1,2,4,5 65BR30/FL/RP 120 6 Reflector Flood C, CC-6 2000 620 lm 53/8
60°
370 cd
15165 1,2,4,5 65BR30/FL 120 24 Reflector Flood C, CC-6 2000 620 lm 53/8
60°
370 cd
13129 1,2,4,5 65BR30/FL 130 24 Reflector Flood C, CC-6 2000 620 lm 53/8
60°
370 cd
15148 1,2,4,5 65BR30/TRAY 120 48 Reflector Flood C, CC-6 2000 620 lm 53/8
60°
370 cd
BR30 PAR38 A19
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
18
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
65 BR30 Med 15150 1,2,4,5 65BR30/A/RP 120 6 Amber Reflector Flood C, CC-6 2000 53/8
15151 1,2,4,5 65BR30/B/RP 120 6 Blue Reflector Flood C, CC-6 2000 53/8
15152 1,2,4,5 65BR30/G/RP 120 6 Green Reflector Flood C, CC-6 2000 53/8
15153 1,2,4,5 65BR30/PK/RP 120 6 Pink Reflector Flood C, CC-6 2000 53/8
15161 1,2,4,5 65BR30/R/RP 120 6 Red Reflector Flood C, CC-6 2000 53/8
15156 1,2,4,5 65BR30/GRO/RP 120 6 Spot-GRO Reflector C, CC-6 2000 53/8
15154 1,2,4,5 65BR30/Y/RP 120 6 Yellow Reflector Flood C, CC-6 2000 53/8
Med Brass 15177 1,2,4,5 65BR30/DL/FL/RP 120 6 Double Life Reflector C, CC-6 4000 510 lm 53/8
Flood 60°
300 cd
PAR38 E26 Med Skt 13804 65PAR/SP 120 15 Spot Super Saver C, CC-6 1750 715 lm 55/16
12°
5500 cd
13802 65PAR/FL 120 15 Flood Super Saver C, CC-6 1750 715 lm 55/16
30°
1700 cd
13805 11 65PAR/FL 130 15 Flood Super Saver C, CC-6 1750 715 lm 55/16
30°
1700 cd
@ 120 volts, approximate 57 watts, 540 lumens, 4375 hours
67 A19 Med 11377 75A/67/SS 120 48 Standard Frost C, CC-8 750 1050 lm 31/847/16
SuperSaver
11381 11 75A/67/SS 130 48 Standard Frost C, CC-8 750 1020 lm 31/847/16
SuperSaver
@ 120 volts, approximate 59 watts, 780 lumens, 1875 hours
11394 75A/67/W/ES/4PK 120 48 Soft White Energy Saver C, CC-8 750 1040 lm 31/847/16
Med Brass 11385 75A/67/SSXL 120 48 Standard Frost C, CC-8 2500 880 lm 31/847/16
SuperSaver XL
11389 11 75A/67/SSXL 130 48 Standard Frost C, CC-8 2500 860 lm 31/847/16
SuperSaver XL
@ 120 volts, approximate 59 watts, 660 lumens, 6250 hours
75 A19 Med 11102 75A/DAY/RP/2/24 120 24 Daylight C, CC-8 750 850 lm 31/847/16
10865 75A/DAY/RP/4/48 120 48 Daylight C, CC-8 750 850 lm 31/847/16
10863 75A/DAY/4/160/RP 120 160 Daylight C, CC-8 750 850 lm 31/847/16
11175 75ACL/DL/RP 120 24 Clear Double Life C, CC-8 1500 1055 lm 31/847/16
11337 75A/DLSW/2PK/RP 120 24 Soft White Double Life C, CC-8 1500 1035 lm 31/847/16
11331 75A/W/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 1500 1035 lm 31/847/16
11360 75A/W/DLSW/4/144/RP 120 144 Soft White Double Life C, CC-8 1500 1035 lm 31/847/16
12579 75A/RS/RP/1 120 12 Inside Frost Rough C, C-9 1000 818 lm 27/847/16
Service
13001 75A/RS/2/RP 120 24 Inside Frost Rough C, C-9 1000 818 lm 27/847/16
Service
12586 11 75A/RS/RP/1 130 24 Inside Frost Rough C, C-9 1000 818 lm 27/847/16
Service
@ 120 volts, approximate 66 watts, 620 lumens, 2500 hours
11225 75A/CL/RP 120 24 Clear C, CC-8 750 1200 lm 31/847/16
12500 75A/CL 120 120 Clear C, CC-8 750 1200 lm 31/847/16
12502 11 75A/CL 130 120 Clear C, CC-8 750 1190 lm 31/847/16
@ 120 volts, approximate 66 watts, 920 lumens, 1875 hours
A19 A21 BR38 BR40 BR30 ER30 K19 PAR38 Side Prong R20
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
19
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
75 A19 Med 10967 75A/W/RP 120 24 Soft White C, CC-8 750 1170 lm 31/847/16
10970 75A/W/4/RP 120 48 Soft White C, CC-8 750 1170 lm 31/847/16
10941 75A/W/4/144/RP 120 144 Soft White C, CC-8 750 1170 lm 31/847/16
12510 75A/CVP 130 24 Standard Frost C, CC-8 750 1190 lm 31/847/16
@ 120 volts, approximate 66 watts, 920 lumens, 1875 hours
12521 75A/RP 120 24 Standard Frost C, CC-8 750 1190 lm 31/847/16
11374 11 75A 130 48 Standard Frost C, CC-8 750 1190 lm 31/847/16
@ 120 volts, approximate 66 watts, 920 lumens, 1875 hours
12525 75A/4/RP 120 48 Standard Frost C, CC-8 750 1190 lm 31/847/16
Med Brass 12528 75A/RS/XL 130 24 Inside Frost Rough C, C-9 5000 700 lm 27/847/16
Service XL
@ 120 volts, approximate 66 watts, 500 lumens, 12500 hours.
A21 Med 12554 15 75A21/RS/SL/RP 120 12 Safeline Rough Service C, C-9 1000 800 lm 31/847/16
Inside Frost
Med Brass 11566 75A21 12 24 Inside Frost RV-Marine C, C-6 1000 1420 lm 37/855/16
BR38 Med 15620 1,4 75/OPAR/BUG/RP 120 6 Outdoor Bug Light C, CC-6 2000 55/16
Med Brass 15618 1,4 75/OPAR/FL/RP 120 6 Outdoor Reflector C, CC-6 2000 650 lm 55/16
Economy Flood 45°
15607 1,4,17 75/OPAR/FL 120 12 Outdoor Reflector C, CC-6 2000 650 lm 55/16
Economy Flood 45°
BR40 Med 15128 2,4,5 75BR/FL/RP 120 6 Reflector Flood C, CC-6 2000 680 lm 61/2
60°
460 cd
15126 2,4,5 75BR/FL 120 24 Reflector Flood C, CC-6 2000 680 lm 61/2
60°
460 cd
15125 2,4,5,11 75BR/FL 130 24 Reflector Flood C, CC-6 2000 680 lm 61/2
60°
460 cd
@ 120 volts, approximate 66 watts, 520 lumens, 5000 hours
Med Brass 15144 2,4,5 75BR/DL/FL/RP 120 6 Double Life Reflector C, CC-6 4000 610 lm 61/2
Flood 60°
400 cd
15213 2,4,5 75BR40/DL/FL/1/24 120 24 Double Life Reflector C, CC-6 4000 610 lm 61/2
Flood 60°
400 cd
ER30 Med 15109 1,2,4,5 75ER30/RP 120 6 Elliptical Reflector C, CC-6 2000 580 lm 63/8
Flood 30°
1500 cd
15100 1,2,4,5 75ER30 120 24 Elliptical Reflector C, CC-6 2000 580 lm 63/8
Flood 30°
1500 cd
15101 1,2,4,5,11 75ER30 130 24 Elliptical Reflector C, CC-6 2000 580 lm 63/8
Flood 30°
1500 cd
@ 120 volts, approximate 66 watts, 440 lumens, 5000 hours
K19 Med 12583 75K19/DR 120 24 Inside Frost C, CC-6 1150 855 lm 41/8
Directional Reflector
PAR38 Med Side 13850 75PAR/3FL 120 12 Compact Flood C, CC-6 2000 1040 lm 45/16
Prong 30°
1800 cd
R20 Med 14840 3,12 75R20/RP 120 6 Reflector Flood C, CC-9 2000 500 lm 315/16
45°
500 cd
R30 A19 A21
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
20
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
75 R30 Med 15146 75R30/BLACKLIGHT/RP 120 6 Blacklight C, CC-6 1000 61/2
90 A19 Med 11378 100A/90/SS 120 48 Standard Frost C, CC-8 750 1480 lm 31/847/16
SuperSaver
11382 11 100A/90/SS 130 48 Standard Frost C, CC-8 750 1480 lm 31/847/16
SuperSaver
@ 120 volts, approximate 79 watts, 1130 lumens, 1875 hours
11396 100A/90/W/ES/4PK 120 48 Soft White Energy Saver C, CC-8 750 1450 lm 31/847/16
Med Brass 11386 100A/90/SS/XL 120 48 Standard Frost C, CC-8 2500 1220 lm 31/847/16
SuperSaver XL
11390 11 100A/90/SS/XL 130 48 Standard Frost C, CC-8 2500 1230 lm 31/847/16
SuperSaver XL
@ 120 volts, approximate 79 watts, 940 lumens, 6250 hours
100 A19 Med 12952 100A/DAY/RP/2/24 120 24 Daylight C, CC-8 750 1270 lm 31/847/16
12587 100A/DAY/RP/4/48 120 48 Daylight C, CC-8 750 1270 lm 31/847/16
12948 100A/DAY/4/160/RP 120 160 Daylight C, CC-8 750 1270 lm 31/847/16
11176 100A/CL/DL/RP 120 24 Clear Double Life C, CC-8 1500 1550 lm 31/847/16
12805 100A/DLSW/2PK/RP 120 24 Soft White Double Life C, CC-8 1500 1530 lm 31/847/16
11332 100A/DLSW/4PK/RP 120 48 Soft White Double Life C, CC-8 1500 1530 lm 31/847/16
11365 100A/DLSW/4/144/RP 120 144 Soft White Double Life C, CC-8 1500 1530 lm 31/847/16
12997 100A/RS/RP/1 120 12 Inside Frost Rough C, C-9 1000 1260 lm 27/847/16
Service
13002 100A/RS/2/RP 120 24 Inside Frost Rough C, C-9 1000 1260 lm 27/847/16
Service
12998 11 100A/RS/2/RP 130 24 Inside Frost Rough C, C-9 1000 1200 lm 27/847/16
Service
@ 120 volts, approximate 88 watts, 960 lumens, 2500 hours
11226 100A/CL/RP 120 24 Clear C, CC-8 750 1720 lm 31/847/16
12529 100A/CL 120 120 Clear C, CC-8 750 1720 lm 31/847/16
12531 11 100A/CL 130 120 Clear C, CC-8 750 1700 lm 31/847/16
@ 120 volts, approximate 88 watts, 1295 lumens, 1875 hours
12752 100A/W/RP 120 24 Soft White C, CC-8 750 1690 lm 31/847/16
12770 100A/W/4/RP 120 48 Soft White C, CC-8 750 1690 lm 31/847/16
12796 100A/W/4/144/RP 120 144 Soft White C, CC-8 750 1690 lm 31/847/16
12735 100A/RP 120 24 Standard Frost C, CC-8 750 1710 lm 31/847/16
12750 100A/4/RP 120 48 Standard Frost C, CC-8 750 1710 lm 31/847/16
12530 100A/LHT 120 120 Standard Frost Left C, CC-8 750 1710 lm 31/847/16
Hand Thread
12709 11 100A/CVP 130 24 Standard Frost C, CC-8 750 1700 lm 31/847/16
@ 120 volts, approximate 88 watts, 1290 lumens, 1875 hours
11375 11 100A 130 48 Standard Frost C, CC-8 750 1700 lm 31/847/16
@ 120 volts, approximate 88 watts, 1290 lumens, 1875 hours
12766 100A/SPK/RP 120 24 Soft Pink C, CC-8 1000 31/847/16
12763 100A/Y/RP 120 24 Yellow Bug Light C, CC-8 1000 31/847/16
Med Brass 12559 11 100A/RS/XL 130 24 Inside Frost Rough C, C-9 5000 1040 lm 27/847/16
Service XL
@ 120 volts, approximate 88 watts, 760 lumens, 12500 hours.
A21 Med 13218 100A21/VS 130 48 Inside Frost Vibration C, C-9 1000 1340 lm 37/855/16
Service
@ 120 volts, approximate 88 watts, 1020 lumens, 2500 hours.
A21 A23 BR38 BR40 K19 PAR38 PAR46
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
21
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
100 A21 Med 13404 100A21 230 24 Standard Frost C, C-9 1000 1260 lm 37/855/16
13406 100A21 250 24 Standard Frost C, C-9 1000 1230 lm 37/855/16
13397 100A21 277 24 Standard Frost C, C-7A 1000 1042 lm 37/855/16
12866 100A21 120 48 Standard Frost C, CC-8 750 1675 lm 37/855/16
12909 100A21/LHT 120 48 Standard Frost Left C, CC-8 750 1675 lm 37/855/16
Hand Thread
12883 11 100A21 130 48 Standard Frost C, CC-8 750 1650 lm 37/855/16
@ 120 volts, approximate 88 watts, 1260 lumens, 1875 hours
Med Brass 12946 11 100A21/99/XL 130 48 Standard Frost Excel C, CC-8 2500 1440 lm 37/855/16
@ 120 volts, approximate 88 watts, 1100 lumens, 6250 hours
12906 100A21/99/XL 120 48 Standard Frost Excel C, CC-8 2500 1400 lm 37/855/16
12834 15 100A21/SL 120 48 Safeline Rhinocoat C, CC-8 750 1675 lm 37/855/16
(Shatter Protected)
12992 15 100A21/RS/SL/RP 120 12 Safeline Rough Service C, C-9 1000 1260 lm 31/847/16
A23 Med 12859 100A23 34 12 Inside Frost C, C-9 1000 1800 lm 43/861/16
Med Brass 13280 100A23/20 120 24 Clear Oven C, C-9 750 1390 lm 43/861/16
12858 100A23 12 24 Inside Frost C, C-6 1000 1940 lm 43/861/16
BR38 Med Brass 15624 1,2,4,5 100/OPAR/FL/A/RP 120 6 Amber Reflector Flood C, CC-6 2000 55/16
15626 1,2,4,5 100/OPAR/FL/B/RP 120 6 Blue Reflector Flood C, CC-6 2000 55/16
15627 1,2,4,5 100/OPAR/FL/G/RP 120 6 Green Reflector Flood C, CC-6 2000 55/16
15623 1,2,4,5 100/OPAR/FL/R/RP 120 6 Red Reflector Flood C, CC-6 2000 55/16
15622 1,2,4,5 100/OPAR/FL/Y/RP 120 6 Yellow Reflector Flood C, CC-6 2000 55/16
BR40 Med 14871 4,5 100BR/FL/RP 120 6 Reflector Flood C, CC-6 2000 935 lm 61/2
60°
900 cd
14851 4,5 100BR/FL 120 24 Reflector Flood C, CC-6 2000 935 lm 61/2
60°
900 cd
14847 4,5,11 100BR/FL 130 24 Reflector Flood C, CC-6 2000 935 lm 61/2
60°
900 cd
@ 120 volts, approximate 88 watts, 710 lumens, 5000 hours
K19 Med 12298 100K19/DR 120 24 Inside Frost C, CC-6 1150 1235 lm 41/8
Directional Reflector
PAR38 E26 Med Skt 13934 100PAR/FL/A/RP 120 6 Silicone Coated Amber C, CC-6 2000 55/16
Flood
13933 100PAR/FL/R/RP 120 6 Silicone Coated Red C, CC-6 2000 55/16
Flood
13948 100PAR/FL/B/RP 120 6 Silicone Coated Blue C, CC-6 2000 55/16
Flood
13949 100PAR/FL/G/RP 120 6 Silicone Coated Green C, CC-6 2000 55/16
Flood
13932 100PAR/FL/Y/RP 120 6 Silicone Coated Yellow C, CC-6 2000 55/16
Flood
13849 2,4,18 100PAR38/HEAT/RED 120 15 Red Lens Heat Lamp C, C-9 5000 55/16
PAR46 Screw Term 15187 5,16 100PAR46 60 12 Mine Locomotive C, CC-2V 800 1290 lm 33/4
S19 Med Brass 18514 100S19/CL/LANDMARK 120 12 Clear Landmark C, C-9 10000 1020 lm 31/847/16
18509 100S19/LANDMARK 120 12 Inside Frost Landmark C, C-9 10000 1000 lm 31/847/16
A23 BR40 ER40 PAR38 Side Prong A19 A21
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
22
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
100 PS25 3CONTACT 14374 100/300PS25/RP 120 12 Inside Frost 3-way C, CC-8 1200 1385 lm 41/463/4
200 Mogul 100/300W 3540 lm
300 4925 lm
105 A23 Med Brass 13364 5 K105A23/CL 125 24 Clear Krypton Filled ST C, C-9 12000 1120 lm 43/861/16
Ltg
120 BR40 Med 14915 1,2,4,5 120BR/DL/FL/RP 120 6 Double Life Reflector C, CC-6 4000 960 lm 61/2
Flood 60°
835 cd
14897 1,2,4,5 120BR/SP/RP 120 6 Reflector Spot C, CC-6 2000 1150 lm 61/2
25°
3300 cd
14911 1,2,4,5 120BR/SP 120 24 Reflector Spot C, CC-6 2000 1150 lm 61/2
25°
3300 cd
14909 1,2,4,5,11 120BR/SP 130 24 Reflector Spot C, CC-6 2000 1150 lm 61/2
25°
3300 cd
@ 120 volts, approximate 105 watts, 880 lumens, 5000 hours
14888 1,2,4,5,11 120BR/FL/CVP 130 6 Reflector Flood C, CC-6 2000 1150 lm 61/2
60°
1000 cd
@ 120 volts, approximate 105 watts, 880 lumens, 5000 hours
14896 1,2,4,5 120BR/FL/RP 120 6 Reflector Flood C, CC-6 2000 1150 lm 61/2
60°
1000 cd
14903 1,2,4,5 120BR/FL 120 24 Reflector Flood C, CC-6 2000 1150 lm 61/2
60°
1000 cd
14899 1,4,11 120BR/FL 130 24 Reflector Flood C, CC-6 2000 1150 lm 61/2
60°
1000 cd
@ 120 volts, approximate 105 watts, 880 lumens, 5000 hours
15074 1,2,4,5 120BR40/FL/SL 130 24 RHINOCOAT Safeline C, CC-6 2000 1150 lm 61/2
Flood 60°
1000 cd
14898 1,2,4,5 120BR/GRO 120 6 Spot-GRO Reflector C, CC-6 2000 61/2
ER40 Med 15166 1,2,4,5 120ER40 120 24 Elliptical Reflector C, CC-6 2000 1370 lm 73/8
Flood 30°
2350 cd
15168 1,2,4,5,11 120ER40 130 24 Elliptical Reflector C, CC-6 2000 1370 lm 73/8
Flood 30°
2350 cd
@ 120 volts, approximate 106 watts, 1040 lumens, 5000 hours
PAR38 Med Side 14572 17 150/120PAR/3FL/SS 120 15 Reflector Flood Super C, CC-6 2000 1900 lm 45/16
Prong Saver 30°
4000 cd
125 BR40 Med 14952 4,5 125BR40/1/RP 120 6 Reflector Infrared C, CC-6 5000 61/2
Brooder Bulb
15006 4,5 BROODERHEAT/1/24 120 24 Brooder Bulb C, CC-6 5000 61/2
135 A19 Med Brass 12830 150A/135/SS/XL 120 120 Standard Frost C, CC-8 2500 2050 lm 31/847/16
SuperSaver XL
12831 11 150A/135/SS/XL 130 120 Standard Frost C, CC-8 2500 2050 lm 31/847/16
SuperSaver XL
@ 120 volts, approximate 119 watts, 1560 lumens, 6250 hours
A21 Med 12820 150A21/135/SS 120 48 Standard Frost C, CC-8 750 2450 lm 37/851/2
SuperSaver
A21 A23 BR38 P25 PAR38 PAR38 Side Prong PAR46
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
23
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
135 A21 Med 12863 11 150A21/135/SS 130 48 Standard Frost C, CC-8 750 2450 lm 37/851/2
SuperSaver
@ 120 volts, approximate 119 watts, 1870 lumens, 1875 hours
150 A21 Med 13125 150A21/CL/RP 120 12 Clear Utility Light C, CC-8 750 2780 lm 37/855/16
13136 150A21/CL 120 48 Clear C, CC-8 750 2780 lm 37/855/16
13148 11 150A21/CL 130 48 Clear C, CC-8 750 2730 lm 37/855/16
@ 120 volts, approximate 132 watts, 2030 lumens, 1875 hours
13101 150A21/W/RP 120 12 Soft White C, CC-8 750 2640 lm 37/855/16
13165 150A21/IF/RP 120 12 Standard Frost Utility C, CC-8 750 2740 lm 37/855/16
Light
13141 150A21 120 48 Standard Frost C, CC-8 750 2740 lm 37/855/16
13153 11 150A21 130 48 Standard Frost C, CC-8 750 2670 lm 37/855/16
@ 120 volts, approximate 132 watts, 2030 lumens, 1875 hours
Med Brass 13177 150A21/99/XL 120 48 Standard Frost Excel C, CC-8 2500 2225 lm 37/855/16
13178 11 150A21/99/XL 130 48 Standard Frost Excel C, CC-8 2500 2225 lm 37/855/16
@ 120 volts, approximate 132 watts, 1690 lumens, 6250 hours
A23 Med 15241 150A23/RS 120 48 Inside Frost Rough C, C-17 1000 2090 lm 43/861/16
Service
15243 11 150A23/RS 130 48 Inside Frost Rough C, C-17 1000 2090 lm 43/861/16
Service
@ 120 volts, approximate 132 watts, 1590 lumens, 2500 hours
13041 150A23 120 48 Inside Frost C, CC-8 750 2810 lm 45/861/16
Med Brass 15250 11 150A23/CL/RS 130 48 Clear Rough Service C, C-17 1000 2110 lm 43/857/8
@ 120 volts, approximate 132 watts, 1590 lumens, 2500 hours
BR38 Med 14869 1,4,17 150/OPAR/FL 120 48 Outdoor Reflector C, CC-6 2000 1350 lm 55/16
Economy Flood 45°
Med Brass 15619 1,4,17 150/OPAR/FL/RP 120 6 Outdoor Reflector C, CC-6 2000 1350 lm 55/16
Economy Flood 45°
15608 1,4,17 150/OPAR/FL 120 12 Outdoor Reflector C, CC-6 2000 1350 lm 55/16
Economy Flood 45°
P25 Med Brass 15014 2 150P25/2SB 120 60 Silver Bowl Clear Hard C, C-5 200 2040 lm 3 43/4
Glass Button
PAR38 E26 Med Skt 13921 17 150PAR/SP 130 15 Spot C, CC-6 750 2175 lm 55/16
12°
18000 cd
@ 120 volts, approximate 132 watts, 1660 lumens, 1875 hours
13922 17 150PAR/FL 130 15 Flood C, CC-6 750 2175 lm 55/16
30°
4500 cd
@ 120 volts, approximate 132 watts, 1660 lumens, 1875 hours
Med Side 13848 16 150PAR/3SP 125 12 Compact Spot C, CC-6 2000 2175 lm 45/16
Prong 15°
11500 cd
13853 16 150PAR/3FL 120 12 Compact Flood C, CC-6 2000 2175 lm 45/16
30°
4000 cd
13854 16 150PAR/3FL 125 12 Compact Flood C, CC-6 2000 2175 lm 45/16
30°
4000 cd
PAR46 Med Side 15375 5,16,19 150PAR46/3NSP 125 12 Narrow Spot C, CC-2V 2000 1500 lm 4
Prong 8 x 12 VH
17500 cd
PAR46 PS25 PAR38 A21 A23
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
24
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
150 PAR46 Screw Term 15190 5,16 150PAR46 130 12 Clear Mine Headlamp C, C-13 1000 1250 lm 33/4
8 x 15 VH
PS25 Med 15255 11 150PS25/VS 130 60 Inside Frost Vibration C, C-9 1000 2080 lm 51/4615/16
Service
@ 120 volts, approximate 132 watts, 1580 lumens, 2500 hours
15207 11 150PS25/CL 130 60 Clear C, C-9 750 2470 lm 51/4615/16
@ 120 volts, approximate 132 watts, 1880 lumens, 1875 hours
15280 150PS25 120 60 Inside Frost C, C-9 750 2470 lm 51/4615/16
15276 150PS25/IF 120 60 Inside Frost C, C-9 1000 2340 lm 51/4615/16
15282 11 150PS25 130 60 Inside Frost C, C-9 750 2330 lm 51/4615/16
@ 120 volts, approximate 132 watts, 1770 lumens, 1875 hours
Med Brass 15431 11 150PS25/99/XL 130 60 Inside Frost Excel-Line C, C-9 2500 1870 lm 51/4615/16
@ 120 volts, approximate 132 watts, 1420 lumens, 6250 hours
15293 15 150PS25/SL 120 60 Safeline Rhinocoat C, C-9 1000 2200 lm 51/4615/16
(Shatter Protected)
15300 15 150PS25/RS/SL 120 60 Safeline Rough Service C, C-17 1000 2145 lm 43/8515/16
T10 S14S 19690 LN150 125 16 Opal White LINESTRA B, C-8 1000 930 lm 393/8
1604
175 PAR38 E26 Med Skt 13836 2,4,18 175W/PAR38/HEAT 120 15 Hard Glass PAR Heat C, CC-6 5000 55/16
Lamp
13840 2,4,18 175 120 15 5000
189 PS25 Med Brass 15562 189PS25/64 120 60 Clear Street Lighting C, C-9 3000 2825 lm 51/4615/16
Group Replacement
200 A21 Med 15476 200A21/CL/RP 120 12 Clear Utility Light C, CC-8 750 3880 lm 37/855/16
15491 11 200A21/CL 130 48 Clear C, CC-8 750 3880 lm 37/855/16
@ 120 volts, approximate 176 watts, 2960 lumens, 1875 hours
13103 200A21/W/1RP 120 12 Soft White C, CC-8 750 3650 lm 37/855/16
13107 200A21 120 24 Soft White Recessed C, CC-8 750 3650 lm 37/855/16
Ceiling
15499 200A21/RP 120 12 Standard Frost Utility C, CC-8 750 3850 lm 37/855/16
Light
15543 11 200A21 130 48 Standard Frost C, CC-8 750 3760 lm 37/855/16
@ 120 volts, approximate 176 watts, 2960 lumens, 1875 hours
Med Brass 15555 11 200A21/99/XL 125 48 Standard Frost Excel C, CC-8 2500 2910 lm 37/855/16
@ 120 volts, approximate 188 watts, 2220 lumens, 6250 hours
A23 Med 15457 200A23/RS 120 48 Inside Frost Rough C, C-17 1000 3030 lm 43/857/8
Service
15458 11 200A23/RS 130 48 Inside Frost Rough C, C-17 1000 2920 lm 43/857/8
Service
@ 120 volts, approximate 176 watts, 2220 lumens, 2500 hours
15505 200A23 120 48 Inside Frost C, CC-8 750 3930 lm 45/861/16
PAR46 Med Side 15194 5,16,19 200PAR46/3MFL 120 12 Medium Flood C, CC-13 2000 2270 lm 4
Prong 15 x 25 VH
11500 cd
15196 5,16,19 200PAR46/3MFL 125 12 Medium Flood C, CC-13 2000 2270 lm 4
15 x 25 VH
11500 cd
15191 5,16,19 200PAR46/3NSP 120 12 Narrow Spot C, CC-13 2000 2270 lm 4
8 x 12 VH
31000 cd
15193 5,16,19 200PAR46/3NSP 125 12 Narrow Spot C, CC-13 2000 2270 lm 4
8 x 12 VH
31000 cd
PAR56 PS25 PS30 BR38 BR40 R40
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
25
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
200 PAR56 Mog End 15007 5,16,19 200PAR56/MFL 120 12 Medium Flood Clear C, CC-13 2000 2270 lm 5
Prong 15 x 20 VH
15000 cd
Screw Term 14968 200PAR56 30 12 Locomotive Headlamp C, CC-8 500 3700 lm 41/2
9 x 9 VH
27000 cd
PS25 Med 15600 11 200PS25 130 60 Inside Frost C, CC-6 750 3700 lm 51/4615/16
@ 120 volts, approximate 176 watts, 2820 lumens, 1875 hours
Med Brass 15816 200PS25/99/XL 120 60 Inside Frost Excel-Line C, CC-6 2500 3000 lm 51/4615/16
15818 11 200PS25/99/XL 130 60 Inside Frost Excel-Line C, CC-6 2500 3000 lm 51/4615/16
@ 120 volts, approximate 176 watts, 2360 lumens, 6250 hours
PS30 Med 15865 200PS30/CL/RS 250 60 Clear Rough Service C, C-9 1000 2630 lm 6 81/16
15647 200PS/CL 130 60 Clear C, C-9 750 3600 lm 6 81/16
@ 120 volts, approximate 176 watts, 2740 lumens, 1875 hours
15797 200PS/CL 250 60 Clear C, C-9 1000 2920 lm 6 81/16
15820 200/CL 277 60 Clear C, C-9 1000 2360 lm 6 81/16
15653 11 200PS/IF 130 60 Inside Frost C, C-9 750 3560 lm 6 81/16
@ 120 volts, approximate 176 watts, 2710 lumens, 1875 hours
15673 200PS/23 120 60 Inside Frost Rough C, C-9 1000 3080 lm 6 81/16
Service
15675 11 200PS/23 130 60 Inside Frost Rough C, C-9 1000 3080 lm 6 81/16
Service
@ 120 volts, approximate 176 watts, 2350 lumens, 2500 hours
Med Brass 15725 11 200PS/CL/99/XL 130 60 Clear Excel-Line C, C-9 2500 2875 lm 6 81/16
@ 120 volts, approximate 176 watts, 2190 lumens, 6250 hours
15691 11 200PS/IF/99/XL 130 60 Inside Frost Excel-Line C, C-9 2500 2875 lm 6 81/16
@ 120 volts, approximate 176 watts, 2190 lumens, 6250 hours
15687 15 200PS/23/SL 120 60 Safeline Rough Service C, C-9 1000 3080 lm 6 81/16
15648 15 200PS/SL 120 60 Safeline C, C-9 1000 3080 lm 6 81/16
202 PS25 Med Brass 15581 5 202PS25/CL 125 60 Clear Street Lighting C, C-9 6000 2750 lm 51/4615/16
Group Replacement
205 PS25 Med Brass 15547 5 205K/PS25/CL 125 60 Clear Street Light C, C-9 12000 2650 lm 51/4615/16
Krypton
250 BR38 Med Brass 14661 2,11 250K/BR38/FL 125 12 Reflector Flood Krypton C, CC-6 4000 3100 lm 513/16
@ 120 volts, approximate 220 watts, 2360 lumens, 10000 hours
BR40 Med 14664 2,4,5,18 250BR40/1 120 6 Reflector IR Heat Lamp C, CC-6 5000 61/2
Clear
14665 2,4,5,18 250BR40 120 12 Reflector IR Heat Lamp C, CC-6 5000 61/2
Clear
R40 Med 14663 2,4,5,18 250R40/10 120 6 Red Bowl IR Heat Lamp C, C-6 5000 67/8
Reflector Hard Glass
300 BR40 Med Brass 14779 1,2,4,5 300BR/FL 120 24 Reflector Flood C, CC-2V 2000 3030 lm 61/2
60°
2900 cd
14781 1,2,4,5,11 300BR/FL 130 24 Reflector Flood C, CC-2V 2000 3030 lm 61/2
60°
2900 cd
@ 120 volts, approximate 264 watts, 2240 lumens, 5000 hours
PAR56 Mog End 14950 16,19 300PAR56/MFL 120 12 Medium Flood C, CC-13 2000 3840 lm 5
Prong 11 x 25 VH
24000 cd
14946 16,19 300PAR56/MFL 130 12 Medium Flood C, CC-13 2000 3840 lm 5
11 x 25 VH
24000 cd
PAR56 PS30 PS35 R40 BR40
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
26
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
300 PAR56 Mog End 14953 16,19 300PAR56/WFL 120 12 Wide Flood C, CC-13 2000 3840 lm 5
20 x 35 VH
11000 cd
14945 16,19 300PAR56/WFL 130 12 Wide Flood C, CC-13 2000 3840 lm 5
20 x 35 VH
11000 cd
14947 16,19 300PAR56/NSP 120 12 Narrow Spot C, CC-13 2000 3840 lm 5
8 x 10 VH
68000 cd
14944 16,19 300PAR56/NSP 130 12 Narrow Spot C, CC-13 2000 3840 lm 5
8 x 10 VH
68000 cd
Screw Term 14967 25A/PAR56/WFL 12 12 Swimming Pool C, C-6 1000 6000 lm 41/2
15 x 40 VH
PS30 Med 15740 300M/CL/RP 120 12 Clear Utility Light C, C-9 750 5870 lm 6 81/16
15742 300M/CL 120 60 Clear Utility Light C, C-9 750 5870 lm 6 81/16
15744 11 300M/CL 130 60 Clear Utility Light C, C-9 750 5820 lm 6 81/16
@ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours
15735 300M/IF/RP 120 12 Inside Frost Utility C, C-9 750 5860 lm 6 81/16
Light
15737 300M/IF 120 60 Inside Frost Utility C, C-9 750 5860 lm 6 81/16
Light
15738 300M/IF/CVP/6 130 6 Inside Frost Utility C, C-9 750 5760 lm 6 81/16
Light
@ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours
15739 11 300M/IF 130 60 Inside Frost Utility C, C-9 750 5760 lm 6 81/16
Light
@ 120 volts, approximate 264 watts, 4390 lumens, 1875 hours
Med Brass 15758 11 300M/CL/99/XL 130 60 Clear Excel-Line C, C-9 2500 5050 lm 6 81/16
@ 120 volts, approximate 264 watts, 3850 lumens, 6250 hours
15761 11 300M/IF/99/XL 130 60 Inside Frost Excel-Line C, C-9 2500 4990 lm 6 81/16
@ 120 volts, approximate 264 watts, 3800 lumens, 6250 hours
PS35 Mogul 15904 300PS35/CL/99/XL 120 24 Clear Excel-Line C, C-9 2500 5190 lm 7 93/8
15925 300PS35/99IF/XL 120 24 Inside Frost Excel-Line C, C-9 2500 5190 lm 7 93/8
15930 300PS35/99IF/XL 130 24 Inside Frost Excel-Line C, C-9 2500 5070 lm 7 93/8
15876 300PS35/RS 130 24 Clear Rough Service C, C-9 1000 5100 lm 7 93/8
15915 300PS35/CL 120 24 Clear Utility Light C, C-9 1000 5700 lm 7 93/8
15917 300PS35/CL 130 24 Clear Utility Light C, C-9 1000 5250 lm 7 93/8
16068 300PS35/CL 277 24 Clear C, C-7A 1000 4220 lm 7 93/8
15918 300PS35/IF 120 24 Inside Frost Utility C, C-9 1000 5700 lm 7 93/8
Light
15920 300PS35/IF 130 24 Inside Frost Utility C, C-9 1000 5250 lm 7 93/8
Light
R40 Mogul 14796 2,4,20 300R/3FL 120 24 Reflector Flood C, CC-2V 2000 3660 lm 71/4
60°
2375 cd
327 PS35 Mogul 16182 327PS35 125 24 Clear Street Lighting C, C-9 6000 4850 lm 7 93/8
Group Replacement
375 BR40 Med Skt 14746 2,4,5,18 375BR40 120 24 IR Reflector Industrial C, C-11 5000 71/4
R40 Med Skt 14747 2,18 375R40/1 120 24 Reflector IR Heat Lamp C, C-11 5000 75/8
Clear
PAR64 PS35 R40 CA B10 F10 G16.5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
27
I
N
C
A
N
D
E
S
C
E
N
T
GENERAL PURPOSE LAMPS
34 Avg Lumens
|
Product Symbols & Pkg Class & Rated Beam Angle LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) CBCP (in) (in)
|
500 PAR64 Ext Mog 14932 5,16,19 500PAR64/MFL 120 6 Medium Flood C, CC-13 2000 6500 lm 6
End Pr 11 x 25 VH
37000 cd
14934 5,16,19 500PAR64/MFL 130 6 Medium Flood C, CC-13 2000 6500 lm 6
11 x 25 VH
37000 cd
14935 5,16,19 500PAR64/WFL 120 6 Wide Flood C, CC-13 2000 6500 lm 6
20 x 40 VH
13000 cd
14937 5,16,19 500PAR64/WFL 130 6 Wide Flood C, CC-13 2000 6500 lm 6
20 x 40 VH
13000 cd
14938 5,16,19 500PAR64/NSP 120 6 Narrow Spot C, CC-13 2000 6500 lm 6
7 x 12 VH
110000 cd
PS35 Mogul 16032 500PS35/CL 120 24 Clear C, CC-8 1000 10000 lm 7 93/8
16034 500PS35/CL 130 24 Clear C, CC-8 1000 10000 lm 7 93/8
16038 500PS35/IF 120 24 Inside Frost C, CC-8 1000 10000 lm 7 93/8
16040 500PS35/IF 130 24 Inside Frost C, CC-8 1000 10000 lm 7 93/8
R40 Mogul 14835 3,5 500R/3FL 120 24 Reflector Flood C, CC-2V 2000 6925 lm 71/4
60°
4355 cd
14857 3,5 500R/3FL 250 24 Reflector Flood C, CC-11 2000 5100 lm 71/4
60°
3000 cd
DECORATIVE LAMPS
1Avg
|
Product Symbols & Pkg Class & Rated MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) (in)
|
2CA8 Candelabra 13497 2CA8C/CL/FL/BL 120 6 Clear Flicker B 3000 31/2
CA10 Med 13496 2CA10/CL/FL/BL 120 6 Clear Flicker B 3000 31/2
15 B10 Candelabra 13315 15B10C/DL/BL 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13448 15B10C/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 37/8
13782 15B10C/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 37/8
13657 15B10CBAGPK 120 200 Clear Décor Bent Tip C, C-7A 1500 37/8
13675 15B10C/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 35/8
Med 13433 6 15B10/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 313/16
13715 6 15B10/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 39/16
F10 Candelabra 13435 15FC/AIC/BL/2PK 120 12 Amber Flame Shape B, C-7A 1500 31/16
Iridescent
13434 15FC/IC/BL/2PK 120 12 Clear Iridescent Flame B, C-7A 1500 31/16
Shape
13436 15FC/W/BL/2PK 120 12 White Flame Shape B, C-7A 1500 31/16
G16.5 Candelabra 13709 15G16.5C/4M 120 24 Clear Globe B, C-7A 4000 3
13616 15G16.5C 120 24 Clear Globe B, C-7A 1500 3
13617 15G16.5C/W 120 24 White Globe B, C-7A 1500 3
25 B10 Candelabra 13306 25B10C/DL/BL/4PK 120 24 Clear Double Life Decor C, C-7A 3000 37/8
Bent Tip
B10 F15 G16.5 G25
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
28
I
N
C
A
N
D
E
S
C
E
N
T
DECORATIVE LAMPS
1Avg
|
Product Symbols & Pkg Class & Rated MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) (in)
|
25 B10 Candelabra 13316 25B10C/DL/BL 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13743 25B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13317 25B10C/DLF/BL 120 12 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13308 25B10C/DLF/BL/4PK 120 24 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13452 25B10C/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 37/8
13570 25B10C/BAGPK 120 200 Clear Décor Bent Tip C, C-7A 1500 37/8
13678 25B10C/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 35/8
13453 25B10C/F/BL/2PK 120 12 Frosted Décor Bent Tip C, C-7A 1500 37/8
Med 13318 6 25B10/DL/BL 120 12 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13331 6 25B10/DL/BL/4PK 120 24 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13438 6 25B10/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 313/16
13654 6 25B10/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 313/16
13717 6 25B10/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 39/16
13439 6 25B10/F/BL/2PK 120 12 Soft White Décor Bent C, C-7A 1500 313/16
Tip
F15 Med 13823 25F/AIC/BL/2PK 120 12 Amber Flame Shape C, C-7A 1500 41/2
Iridescent
13806 25F/CL 120 24 Clear Flame Shape C, C-7A 1500 41/2
13821 25F/IC/BL/2PK 120 12 Iridescent Flame Shape C, C-7A 1500 41/2
13820 25F/W/BL/2PK 120 12 Soft White Flame Shape C, C-7A 1500 41/2
G16.5 Candelabra 13704 25G16.5C/4M 120 24 Clear Globe B, C-7A 4000 3
13703 25G16.5C/W/4M 120 24 Soft White Globe B, C-7A 4000 3
13625 25G16.5C/BL 120 12 Clear Globe B, C-7A 1500 3
13618 25G16.5C 120 24 Clear Globe B, C-7A 1500 3
13622 25G16.5C/W/BL 120 12 White Globe B, C-7A 1500 3
Med 10298 25G16.5/BL 120 12 Clear Globe C, C-7A 1500 3
10297 25G16.5/W/BL 120 12 White Globe C, C-7A 1500 3
G25 Med 14145 25G25/DL/RP 120 6 Clear Double Life Globe C, C-9 3000 47/16
14276 25G25/4M 120 24 Clear Globe C, C-9 4000 47/16
14146 25G25/DLSW/RP 120 6 Soft White Double Life C, C-9 3000 47/16
Globe
14103 25G25/DLSW/RP/48 120 48 Soft White Double Life C, C-9 3000 47/16
Globe
14277 25G25/W/4M 120 24 Soft White Globe C, C-9 4000 47/16
14105 25G25/DL/RP/48 120 48 Clear Double Life Globe C, C-9 3000 47/16
14282 25G25/RP 120 6 Clear Globe C, C-9 1500 47/16
14264 25G25 120 24 Clear Globe C, C-9 1500 47/16
14210 25G25/3PK/RP 120 24 Clear Globe C, C-9 1500 47/16
14286 25G25/W/RP 120 6 Soft White Globe C, C-9 1500 47/16
14265 25G25/W 120 24 Soft White Globe C, C-9 1500 47/16
G25 G30 G40 B10 F15 G16.5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
29
I
N
C
A
N
D
E
S
C
E
N
T
DECORATIVE LAMPS
1Avg
|
Product Symbols & Pkg Class & Rated MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) (in)
|
25 G25 Med 14211 25G25/W/3PK/RP 120 24 Soft White Globe C, C-9 1500 47/16
G30 Med 14404 25G30/W/RP 120 6 Soft White Globe C, C-9 2500 51/2
G40 Med 14685 25G40 120 6 Clear Globe C, C-9 2500 615/16
14901 25G40/W 120 6 Soft White Globe C, C-9 2500 615/16
32 B10 Candelabra 13737 32B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 4000 37/8
Bent Tip
40 B10 Candelabra 13319 40B10C/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13328 40B10C/DL/BL/4PK 120 24 Clear Double Life Decor C, C-7A 3000 37/8
Bent Tip Four Pack
13741 40B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13714 40B10C/CRYSTAL/DL/BL/4/24 120 24 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13320 40B10C/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13309 40B10C/DLF/BL/4PK 120 24 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13456 40B10C/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 37/8
13648 40B10C/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 37/8
13571 40B10C/BAGPK 120 200 Clear Décor Bent Tip C, C-7A 1500 37/8
13681 40B10C/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 35/8
13457 40B10C/F/BL/2PK 120 12 Frosted Décor Bent Tip C, C-7A 1500 37/8
13682 40B10C/F/T/BL/2PK 120 12 Frosted Décor Blunt Tip C, C-7A 1500 35/8
Med 13321 6 40B10/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13740 6 40B10/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 313/16
Bent Tip
13723 6 40B10/CRYSTAL/DL/BL/4PK 120 24 Double Life Crystal C, C-7A 3000 313/16
Bent Tip
13322 6 40B10/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 313/16
Décor Bent Tip
13440 6 40B10/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 313/16
13651 6 40B10/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 313/16
13719 6 40B10/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 39/16
13720 6 40B10/F/T/BL/2PK 120 12 Frosted Décor Blunt Tip C, C-7A 1500 39/16
13441 6 40B10/F/BL/2PK 120 12 Soft White Décor Bent C, C-7A 1500 313/16
Tip
F15 Med 13986 40F/AIC/BL/2PK 120 12 Amber Flame Shape C, C-7A 1500 41/2
Iridescent
13974 40F/CL 120 24 Clear Flame Shape C, C-7A 1500 41/2
13985 40F/IC/BL/2PK 120 12 Iridescent Flame Shape C, C-7A 1500 41/2
13984 40F/W/BL/2PK 120 12 White Flame Shape C, C-7A 1500 41/2
G16.5 Candelabra 13700 40G16.5C/4M 120 24 Clear Globe C, C-7A 4000 3
13699 40G16.5C/W/4M 120 24 Soft White Globe C, C-7A 4000 3
13666 40G16.5C/BL 120 12 Clear Globe C, C-7A 1500 3
13702 40G16.5C 120 24 Clear Globe C, C-7A 1500 3
G16.5 G25 G30 G40 A19 B10
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
30
I
N
C
A
N
D
E
S
C
E
N
T
DECORATIVE LAMPS
1Avg
|
Product Symbols & Pkg Class & Rated MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) (in)
|
40 G16.5 Candelabra 13667 40G16.5C/W/BL 120 12 White Globe C, C-7A 1500 3
Med 10300 40G16.5/BL 120 12 Clear Globe C, C-7A 1500 3
10299 40G16.5/W/BL 120 12 White Globe C, C-7A 1500 3
G25 Med 13966 40G25/DAY/1/6 120 6 Daylight Globe C, C-9 1500 47/16
14002 40G25/DAY/1/48 120 48 Daylight Globe C, C-9 1500 47/16
14147 40G25/DL/RP 120 6 Clear Double Life Globe C, C-9 3000 47/16
14148 40G25/DLSW/RP 120 6 Soft White Double Life C, C-9 3000 47/16
Globe
14175 40G25/DLSW/1/48 120 48 Soft White Double Life C, C-9 3000 47/16
Globe
14174 40G25/DL/1/48 120 48 Clear Double Life Globe C, C-9 3000 47/16
14191 40G25/CVP/130V 130 6 Clear Globe C, C-9 1500 47/16
14283 40G25/RP 120 6 Clear Globe C, C-9 1500 47/16
14266 40G25 120 24 Clear Globe C, C-9 1500 47/16
14212 40G25/3PK/RP 120 24 Clear Globe C, C-9 1500 47/16
14190 40G25/W/CVP130V 130 6 Soft White Globe C, C-9 1500 47/16
14287 40G25/W/RP 120 6 Soft White Globe C, C-9 1500 47/16
14267 40G25/W 120 24 Soft White Globe C, C-9 1500 47/16
14213 40G25/W/3PK/RP 120 24 Soft White Globe C, C-9 1500 47/16
14235 40G25/W/DIYPACK 120 24 Soft White Globe C, C-9 1500 47/16
G30 Med 14405 40G30/W/RP 120 6 Soft White Globe C, C-9 2500 51/2
G40 Med 14619 40G40/RP 120 6 Clear Globe C, C-9 2500 615/16
14620 40G40/W/RP 120 6 Soft White Globe C, C-9 2500 615/16
60 A19 Med Brass 10613 60A/SB 120 120 Silver Bowl C, CC-8 1000 47/16
B10 Candelabra 13777 60B10C/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 37/8
Bent Tip
13705 60B10C/DL/BL/4PK 120 24 Clear Double Life Decor C, C-7A 3000 37/8
Bent Tip Four Pack
13744 60B10C/CRYSTAL/DL/BL/2PK 120 12 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13749 60B10C/CRYSTAL/DL/BL/4/24 120 24 Double Life Crystal C, C-7A 3000 37/8
Bent Tip
13778 60B10C/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13754 60B10C/DLF/BL/4PK 120 24 Frosted Double Life C, C-7A 3000 37/8
Décor Bent Tip
13460 60B10C/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 37/8
13649 60B10C/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 37/8
13572 60B10C/BAGPK 120 200 Clear Décor Bent Tip C, C-7A 1500 37/8
13684 60B10C/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 35/8
13461 60B10C/F/BL/2PK 120 12 Frosted Décor Bent Tip C, C-7A 1500 37/8
13685 60B10C/F/T/BL/2PK 120 12 Frosted Décor Blunt Tip C, C-7A 1500 35/8
Med 13323 60B10/DL/BL/2PK 120 12 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
13333 60B10/DL/BL/4PK 120 24 Clear Double Life Décor C, C-7A 3000 313/16
Bent Tip
B10 C15 F15 G16.5 G25 G30 G40 A21 P25 PS25 PS35
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
31
I
N
C
A
N
D
E
S
C
E
N
T
DECORATIVE LAMPS
1Avg
|
Product Symbols & Pkg Class & Rated MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) (in)
|
60 B10 Med 13324 60B10/DLF/BL/2PK 120 12 Frosted Double Life C, C-7A 3000 313/16
Décor Bent Tip
13442 60B10/BL/2PK 120 12 Clear Décor Bent Tip C, C-7A 1500 313/16
13650 60B10/BL/4PK 120 24 Clear Décor Bent Tip C, C-7A 1500 313/16
13721 60B10/T/BL/2PK 120 12 Clear Décor Blunt Tip C, C-7A 1500 39/16
13443 60B10/F/BL/2PK 120 12 Frosted Décor Bent Tip C, C-7A 1500 313/16
13722 60B10/F/T/BL/2PK 120 12 Frosted Décor Blunt Tip C, C-7A 1500 39/16
C15 Med 13757 60C15/SG/BL 120 6 Spun-Glo Clear Fiber C, C-9 4000 41/2
Wrapped
F15 Med 13992 60F/BL 120 12 Clear Flame Shape C, C-7A 1500 41/2
13993 60F/CL 120 24 Clear Flame Shape C, C-7A 1500 41/2
13982 60F/IC/BL/2PK 120 12 Iridescent Flame Shape C, C-7A 1500 41/2
G16.5 Candelabra 13665 60G16.5C/BL 120 12 Clear Globe C, C-2 1500 3
13664 60G16.5C/W/BL 120 12 Soft White Globe C, C-2 1500 3
Med 10302 60G16.5/BL 120 12 Clear Globe C, C-7A 1500 3
10301 60G16.5/W/BL 120 12 White Globe C, C-7A 1500 3
G25 Med 13967 60G25/DAY/1/6 120 6 Daylight Globe C, C-9 1500 47/16
14003 60G25/DAY/1/48 120 48 Daylight Globe C, C-9 1500 47/16
14149 60G25/DL/RP 120 6 Clear Double Life Globe C, C-9 3000 47/16
14150 60G25/DLSW/RP 120 6 Soft White Double Life C, C-9 3000 47/16
Globe
14104 60G25/DLSW/RP/48 120 48 Soft White Double Life C, C-9 3000 47/16
Globe
14106 60G25/DL/RP/48 120 48 Clear Double Life Globe C, C-9 3000 47/16
14261 60G25/RP 120 6 Clear Globe C, C-9 1500 47/16
14280 60G25 120 24 Clear Globe C, C-9 1500 47/16
14214 60G25/3PK/RP 120 24 Clear Globe C, C-9 1500 47/16
14262 60G25/W/RP 120 6 Soft White Globe C, C-9 1500 47/16
14281 60G25/W 120 24 Soft White Globe C, C-9 1500 47/16
14215 60G25/W/3PK/RP 120 24 Soft White Globe C, C-9 1500 47/16
G30 Med 14407 60G30/RP 120 6 Clear Globe C, C-9 2500 51/2
14406 60G30/W/RP 120 6 Soft White Globe C, C-9 2500 51/2
G40 Med 14621 60G40/RP 120 6 Clear Globe C, C-9 2500 615/16
14622 60G40/W/RP 120 6 Soft White Globe C, C-9 2500 615/16
100 A21 Med 13195 2 100A21/1SB/IF 120 24 Silver Bowl C, CC-6 1000 55/16
G40 Med 14623 100G40/RP 120 6 Clear Globe C, C-9 2500 615/16
14624 100G40/W/RP 120 6 Soft White Globe C, C-9 2500 615/16
150 G40 Med 14913 150G40/W/RP 120 6 Soft White Globe C, C-9 2500 615/16
P25 Med Brass 15014 2 150P25/2SB 120 60 Silver Bowl Clear Hard C, C-5 200 43/4
Glass Button
PS25 Med 15271 150PS25/SB 120 60 Silver Bowl C, C-9 1000 615/16
300 PS35 Mogul 15958 300PS35/SB/IF 120 24 Silver Bowl Inside C, C-9 1000 93/8
Frost Brass Base
A19 A21 A23
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 33
32
I
N
C
A
N
D
E
S
C
E
N
T
TRAFFIC SIGNAL LAMPS
3Avg
|
Product Symbols & Pkg Class & Rated Approx LCL MOL
|
Watts Bulb Base NumberFootnotes Ordering Abbreviation Volts Qty Description Filament Life(hrs) Lumens (in) (in)
|
54 A19 Med Brass 10441 13 54A19TS/8M/SS 120 120 Clear Traffic Signal KR C, C-11V 8000 515 27/16 47/16
Filled w/ Heat Reflector
60 A19 Med Brass 10442 13 60A19TS/8M/SS 120 120 Clear Traffic Signal KR C, C-11V 8000 595 27/16 47/16
Filled w/ Heat Reflector
67 A21 Med Brass 12570 67A21/40/8M 120 24 Clear Traffic Signal C, C-9 8000 610 27/16 47/16
12562 67A21/40/8M 130 120 Clear Traffic Signal C, C-9 8000 610 27/16 47/16
12572 67A21/40/8M 130 24 Clear Traffic Signal C, C-9 8000 610 27/16 47/16
69 A21 Med Brass 12496 69A21/TS/8M 120 24 Clear Traffic Signal C, C-9 8000 640 27/16 47/16
12497 69A21/TS/8M 125 24 Clear Traffic Signal C, C-9 8000 665 27/16 47/16
12498 69A21/TS/8M 130 24 Clear Traffic Signal C, C-9 8000 640 27/16 47/16
90 A19 Med Brass 12299 13 90A19/1/TS/8M/SS 120 120 Clear Traffic Signal KR C, C-11V 8000 1000 3 47/16
Filled w/ Heat Reflector
11151 13 90A19/TS/8M/SS 120 120 Clear Traffic Signal KR C, C-11V 8000 1000 27/16 47/16
Filled w/ Heat Reflector
101 A23 Med Brass 13305 101A23/6M 120 120 Inside Frost Traffic C, C-9 6000 900 43/861/16
Signal
116 A21 Med Brass 12833 116A21/TS/8M 120 24 Clear Traffic Signal C, C-9 8000 1260 27/16 47/16
12838 116A21/TS/8M 125 24 Clear Traffic Signal C, C-9 8000 1235 27/16 47/16
12817 116A21/TS/8M 130 24 Clear Traffic Signal C, C-9 8000 1260 27/16 47/16
135 A21 Med Brass 12843 13 135A21/TS/8M/SS 120 24 Clear Traffic Signal KR C, C-11V 8000 1750 3 47/16
Filled w/ Heat Reflector
170 A23 Med Brass 15017 1950L/A23/8M 120 60 Clear Traffic Signal C, C-9 8000 1950 3 43/4
15019 1950L/A23/8M 125 60 Clear Traffic Signal C, C-9 8000 1950 3 43/4
15021 1950L/A23/8M 130 60 Clear Traffic Signal C, C-9 8000 1950 3 43/4
For more complete product information visit www.sylvania.com 33
I
N
C
A
N
D
E
S
C
E
N
T
SYMBOLS & FOOTNOTES FOR INCANDESCENT LAMPS
Symbol Description
New item introduced within the past year.
Indicates aluminum base.
Do not operate in household sockets.
Operate base down.
Operate base down to horizontal.
Heat resistant, hard glass.
PAR lamps are suitable for indoor and outdoor use.
Not recommended for horizontal operation.
Do not operate in paper lined sockets.
Operate in any position.
This lamp or ballast meets minimum Federal efficiency standards.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
Lamp qualifies as Risk Group 3 per ANSI / IESNA RP27.3-96.
Use Caution when operating this product. Read and understand all warnings and instructions on packaging before installation.
Footnote Description
1Should not be used in equipment where base temperature will exceed 500˚ F.
2Operate only in porcelain sockets.
3Not recommended for use in enclosed close-fitting housings.
4May not give satisfactory performance if any accessory lighting equipment touches the glass bulb.
5Should be shielded against moisture falling on bulb.
6Not for use in ceiling fan fixtures
7Nominal wattage - actual may be slightly higher to achieve required light output.
8Indefinite long life. Designed for life in excess of 10,000 hours. In-service life depends upon burning conditions.
9Average laboratory life is 200 hours for vacuum cleaner and 600 hours for sewing machine services.
10 Additional product information can be found in the SYLVANIA Automotive, Miniature and Sealed Beam Lamp Catalog Form 208.
11 Incandescent lamps operated at less than rated voltage provide a lower light output, longer life, lower color temperature and are less efficient
in terms of lumens per watt.
12 In base up operation, heat may eventually deteriorate paper-lined or plastic sockets.
13 Minimum run. Check nearest OSRAM SYLVANIA Sales Office for details.
14 For diesel electric locomotives without voltage regulators.
15 Operation of lamp in any position other than base up may result in some loss of protective coating.
16 For use only with heat-resisting connector and with bulb supported by bulb rim or metal shell of base.
17 Operate only in porcelain or other socket approved for 150 watt PAR lamp.
18 Designed for service other than illumination.
19 A protective shield must be used external to the lamp.
20 High temperature base. Designed to operate in equipment where base temperature run between 500F - 570F.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
34
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
OSRAM SYLVANIA: THE LEADER IN
HALOGEN LAMP TECHNOLOGY
Halogen lamps are generally of the 'lamp within a lamp' design. The outer 'lamp' or jacket is made from a heavy walled borosilicate glass.
The inner 'lamp' is the tungsten halogen capsule that is made from either glass or quartz and contains
a filament, lead wires and a halogen gas mixture.
Save energy while still making your merchandise stand out from the crowd. Energy
efficient SYLVANIA CAPSYLITE IR lamps use a specially designed halogen light source
that actually recycles some of the heat it creates to generate more light for less energy.
The special blue lenses on these halogen PAR lamps help to fill your space with whiter, more natural light.
PAR38 lamps are energy saving replacements for standard incandescent BR40 lamps. They are also the
workhorses of retail lighting. SYLVANIA CAPSYLITE SPL PAR38 lamps offer cutting edge optics and optimal
performance to make your merchandise look its best.
These energy efficient replacements for BR30 lamps are used everywhere from recessed
cans to track lights. More efficient than competitors long neck PAR30 lamps because of
our unique neck extender design, SYLVANIA PAR30LN SPL®lamps are the perfect
choice every time.
SYLVANIA CAPSYLITE SPL PAR20 lamps are energy saving replacements for standard incandescent R20
lamps. Replacing a 50W R20 lamp with a SYLVANIA exclusive 35PAR20 lamp results in an energy savings of
15W per lamp with an increase in light output of nearly 10%!
SYLVANIA's complete line of TRU-AIM low voltage lamps offer something for everyone.
Choose from standard MR16s (TRU-AIM), aluminized MR16s (TRU-AIM Brilliant) or top
of the line TRU-AIM IR.
Replace a standard incandescent lamp with a CAPSYLITE Daylight Plus A-Line lamp to
get a crisp, bright, more natural light that really lasts. Average rated life for these lamp
types is 3,000 to 3,500 hours - up to four times the ratings of the lamps that they
replace!
CAPSYLITE IR®
PAR38
PAR20
CAPSYLITE®Daylight Plus A-Line
Daylight PlusPAR
PAR30 Long Neck
TRU-AIM®Low Voltage Lamps
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
35
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
FILAMENTS
CC-8 CC-2V CC-6 Axial (AX) Tranverse (TR) C-8 Double End
BASES
E10 E11 Mini can E26 Medium Skt. E26 Medium Recessed Single Contact Screw Term. DC Bayonet Mogul End Prong
Miniture Screw RSC B15d
R7s BA15d
G4 G9 G53 GY 6.35 GU4 GU5.3 GU10 Med Side Pr.
LAMPS
T3, T4 BI-PIN T4 G9. MR16, MR11 PAR14 PAR16 PAR16 GU10 PAR20
PAR30 PAR30LN PAR36 PAR38 PAR38 AR70 AR111
Medium Skt. Medium Side Prong
PAR56 Mog End Pr PAR64 Mog End Pr T4 DC Bayonet T3, T4 Mini Can T3, T4 RSC Double End T10 A19
Ext. Mog.
End Prong
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
36
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
The following item was accepted into 2003 IESNA Progress Report which recognizes innovative products introduced
to the industry during that year.
40 Watt PAR 20 CAPSYLITE IR®
HOW TO READ PRODUCT INFORMATION - TUNGSTEN HALOGEN
4Avg
|
Product Symbols & Pkg Lamp Beam Class & Rated Approx Beam LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Type Filament Life (hrs) Lumens CBCP Angle (in) (in)
|
40 T4 G9 57017 5,10 40CAPSYLITEG9/F/BL 120 10 Frosted C, CC-2V 2000 480 1 1
78
60 PAR38 E26 Med Skt 14466 10,11 60PAR/CAP/IR/FL30 120 15 Flood Flood CC-8 3000 1110 3600 30 5 516
50 PAR30LN E26 Med 14520 10,19,20 50PAR30LN/CAP/NFL25 120 15 Narrow FloodCC-8 2500 660 2300 25 4 1116
Bulb Describes the shape of the bulb followed by the bulb’s major diameter given in eighths of an inch.
See page 35: Halogen Lamps.
Base See page 35: Base Identification.
Symbols & All symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
Footnotes footnotes are at the end of the halogen section on page 56-57.
Lamp Finish Applies only to non-reflector type lamps, usually either clear or frosted.
Beam Type Applies only to reflector type lamps. Describes the beam angle qualitatively as either a spot or a flood, etc.
How to Read Ordering Abbreviations
40CAPSYLITE®/G9/F/BL 60PAR/CAP/IR/FL30 50PAR30LN/CAP/SPL/NFL25
ANSI BEAM ANGLE DESIGNATION
Beam angles for reflector lamps are designated to conform with ANSI C78.379 -Classification of the Beam Patterns of Reflector Lamps. For
beam angles less than 13°, beam angles are rounded to the nearest whole number. For beam angles between 13° and 50°, values are round-
ed to the nearest 5°. For beam angles 50° and greater, the value is rounded to the nearest 10°. As an example, a family of lamps with an
average beam angle of 13° is classified as 15°, and a family of lamps with an average beam angle of 55° would be classified as 60°.
LIFE RATING
The average rated life for 130V tungsten halogen lamps operated at 120V is conservatively estimated to be approximately 2 times the life
when operated at rated voltage (130V).
ANSI CODE REFERENCE GUIDE
BAB 54200 20MR16/FL/40 12 53
EHM 58923 300T3Q/CL 120 50
EHT 58762 250Q/CL/MC 120 49
ESL 58738 150Q/CL/MC 120 49
ESM 58763 250Q/MC 120 49
ESN 58761 100Q/CL/MC 120 49
ESP 58742 150Q/CL/DC/1 120 49
ESR 58755 100Q/CL/DC 120 49
ESS 58720 250Q/CL/DC 120 49
ESX 54201 20MR16/NSP/8 12 53
ETB 58753 250Q/DC 120 49
ETC 58741 150Q/CL/DC 120 49
ETD 58757 100Q/DC 120 49
ETF 58737 150Q/DC 120 49
ETG 58735 150Q/CL/MC/2 120 49
ETH 58736 150Q/MC 120 49
EVR 58766 500Q/CL/MC 120 49
EXN 54207 50MR16/FL/40 12 53
EXT 54208 50MR16/NSP/12 12 53
EXZ 54205 50MR16/NFL/25 12 53
EYT 58769 750Q/CL/MC 120 49
EYV 58768 500Q/MC 130 49
EYW 58756 500Q/CL/MC 130 49
EYX 58767 500Q/MC 120 49
FCL 58856 500T3Q/CL 120 50
FCZ 58883 500T3Q 120 49
FMW 54203 35MR16/FL/40 12 53
FNV 54206 50MR16/VWFL60 12 53
FRA 58602 35MR16/SP20 12 53
FRB 54204 35MR16/NSP/8 12 53
FPA 58563 65MR16/NSP/10 12 53
FPC 58565 65MR16/NFL/25 12 53
FPB 58564 65MR16/FL/40 12 53
FTB 55109 20MR11/SP10 12 53
FTD 55107 20MR11/FL35 12 53
FTE 55113 35MR11/SP10 12 53
FTH 55111 35MR11/FL40 12 53
L.L. ORDERING
ANSI ITEM ABBREVIATION
CODE NO. (EXCEPT VOLTS) VOLTS PAGE
L.L. ORDERING
ANSI ITEM ABBREVIATION
CODE NO. (EXCEPT VOLTS) VOLTS PAGE
L.L. ORDERING
ANSI ITEM ABBREVIATION
CODE NO. (EXCEPT VOLTS) VOLTS PAGE
40 Nominal lamp wattage 60 Nominal lamp wattage 50 Nominal lamp wattage
CAPSYLITE/G9CAPSYLITE lamp with G9 base PAR Bulb shape PAR38 PAR30LN Bulb shape PAR30 Long Neck
FFrosted finish CAP CAPSYLITE lamp CAP CAPSYLITE lamp
BL Blister Card Package IR Infrared conserving capsule SPL®SPL Optical System
FL30 Flood beam 30 degrees NFL25 Narrow Flood beam 25 degrees
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
37
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
TUNGSTEN HALOGEN BRAND NAME GUIDE
SYLVANIA GE* PHILIPS** OSRAM***
CAPSYLITE®SPL®PAR38 HALOGEN PLUS PAR 38 MasterLine PAR38 DiOptic HALOPAR38
CAPSYLITE SPL PAR30 Compact PAR30 MasterLine PAR30S WISO HALOPAR30
CAPSYLITE SPL PAR30 Long Neck Compact PAR30 Long Neck MasterLine PAR30L Long Neck WISO
CAPSYLITE SPL PAR20 Compact PAR20 MasterLine PAR20 WISO HALOPAR20
CAPSYLITE Designer 16 HALOGEN Compact PAR16 MasterLine PAR16 HALOPAR16
TRU-AIM TITAN®ConstantColor Precise Continuum Color Decostar 51 TITAN
TRU-AIM®Standard MR16 Standard MR16 BrilliantLine Pro MR16 Decostar 51
TRU-AIM IR PRECISE COVERGLASS IR MR16 MasterLine ES IRC MRC16 Decostar 51 IRC
TRU-AIM Standard MR11 STANDARD MR11 BrilliantLine Pro MRC11 Decostar 35
TRU-AIM BRILLIANT®Continuum Pro Aluminum Coated Decostar 51 ALU
STANDARD Bi-Pin Quartz Halogen Halogen Low Voltage Capsule HALOSTAR Standard
STARLITE Bi-Pin Halogen Low Voltage Capsule HALOSTAR STARLITE
Double End Quartzline Halogen Halogen Double-Ended Linear HALOLINE
SUPER Q Quartzline Halogen Halogen Single-Ended HALOLUX Ceram
Double End Quartz Infrared Heat Tubular Quartz Heat Quartz Infrared Heat
Large PAR Quartzline Halogen Halogen PAR56 and PAR64
CAPSYLITE A-Line Midbreak Halogen A-Line Halogena HALOLUX BT
Halogen T10 HALOLUX Ceram
AR111 HALOSPOT 111
AR70 HALOSPOT 70
SYLVANIA 250W CAPSYLITE PAR 38 Quartzline PAR38
CAPSYLITE IR®PAR38 HIR PAR 38 MasterLine IRC PAR38
CAPSYLITE IR PAR30 Compact HIR PAR 30
CAPSYLITE COOL-LUX Cool Beam PAR 38
* Trademark or registered trademarks of General Electric Company. ** Trademark or registered trademarks of Philips. *** Trademark or registered trademarks of OSRAM.
For weight and measurement information, please visit www.sylvania.com
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
38
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®A-LINE
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
42 A19 E26 Med 18907 42A/CAP 120 12 Inside C, CC-8 3500 570 31/843/8
Frost
18908 1 42A/CAP 130 12 Inside C, CC-8 3500 570 31/843/8
Frost
@ 120 volts, approximate 37 watts, 450 lumens, 7000 hours
52 A19 E26 Med 18921 52A/CAP 120 12 Inside C, CC-8 3500 770 31/843/8
Frost
18922 1 52A/CAP 130 12 Inside C, CC-8 3500 770 31/843/8
Frost
@ 120 volts, approximate 46 watts, 600 lumens, 7000 hours
72 A19 E26 Med 18937 72A/CAP 120 12 Inside C, CC-8 3500 1150 31/843/8
Frost
18938 1 72A/CAP 130 12 Inside C, CC-8 3500 1150 31/843/8
Frost
@ 120 volts, approximate 63 watts, 900 lumens, 7000 hours
DAYLIGHT PLUS™ A-LINE
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
60 A19 E26 Med 18998 60A/HAL/DAY/CL/CLAM 120 6 Clear C, CC-8 3000 960 31/843/8
18999 60A/HAL/DAY/CLAM 120 6 Frosted C, CC-8 3000 960 31/843/8
18942 60A/HAL/DAY/CRYSTAL/CLAM 120 6 Crystal C, CC-8 3000 960 31/843/8
75 A19 E26 Med 19000 75A/HAL/DAY/CL/CLAM 120 6 Clear C, CC-8 3000 1330 31/843/8
18997 75A/HAL/DAY/CLAM 120 6 Frosted C, CC-8 3000 1300 31/843/8
18906 75A/HAL/DAY/CRYSTAL/CLAM 120 6 Crystal C, CC-8 3000 1330 31/843/8
100 A19 E26 Med 19003 100A/HAL/DAY/CL/CLAM 120 6 Clear C, CC-8 3000 1800 31/843/8
18905 100A/HAL/DAY/CLAM 120 6 Frosted C, CC-8 3000 1800 31/843/8
TUBULAR HALOGEN T10
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
75 T10 E26 Med 18890 2 75T10/HAL/CL 120 15 Clear C, CC-2V 2000 1100 215/16 41/8
18891 2 75T10/HAL/F 120 15 Frosted C, CC-2V 2000 1050 215/16 41/8
100 T10 E26 Med 18892 2 100T10/HAL/CL 120 15 Clear C, CC-2V 2000 1500 215/16 41/8
18893 2 100T10/HAL/F 120 15 Frosted C, CC-2V 2000 1430 215/16 41/8
150 T10 E26 Med 18894 2,3 150T10/HAL/CL 120 15 Clear C, CC-2V 2000 2500 215/16 41/8
18895 2,3 150T10/HAL/F 120 15 Frosted C, CC-2V 2000 2400 215/16 41/8
250 T10 E26 Med 18896 2,3 250T10/HAL/CL 120 15 Clear C, CC-2V 2000 4200 215/16 41/8
18897 2,3 250T10/HAL/F 120 15 Frosted C, CC-2V 2000 4000 215/16 41/8
A19 T10
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
39
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
INFRARED CONSERVING HALOGEN
TRU-AIM IR®MR16
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on the lamp capsule.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR16 GU5.3 58531 4,5,6, 20MR16/IR/SP10/C 12 20 Spot C, AX 4000 6000 10 13/4
7,8
58532 4,5,6, 20MR16/IR/NFL25/C 12 20 Narrow C, AX 4000 2300 25 13/4
7,8 Flood
58533 4,5,6, 20MR16/IR/FL40/C 12 20 Flood C, AX 4000 1000 40 13/4
7,8
58838 4,5,6, 20MR16/IR/WFL60/C 12 20 Wide Flood C, AX 4000 450 60 13/4
7,8
37 MR16 GU5.3 58641 4,5,6, 37MR16/IR/SP10/C 12 20 Spot C, AX 4000 12500 10 13/4
8,10
58634 4,5,6, 37MR16/IR/NFL25/C 12 20 Narrow C, AX 4000 4400 25 13/4
8,10 Flood
58633 4,5,6, 37MR16/IR/FL40/C 12 20 Flood C, AX 4000 2200 40 13/4
8,10
58837 4,5,6, 37MR16/IR/WFL60/C 12 20 Wide Flood C, AX 4000 1100 60 13/4
8,10
50 MR16 GU5.3 54175 4,5,6, 50MR16/IR/SP10/C 12 20 Spot C, AX 4000 15000 10 13/4
8,10
54174 4,5,6, 50MR16/IR/NFL25/C 12 20 Narrow C, AX 4000 5700 25 13/4
8,10 Flood
54173 4,5,6, 50MR16/IR/FL40/C 12 20 Flood C, AX 4000 2850 40 13/4
8,10
54237 4,5,6, 50MR16/IR/WFL60/C 12 20 Wide Flood C, AX 4000 1430 60 13/4
8,10
CAPSYLITE IR®PAR20
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
40 PAR20 E26 Med 14164 40PAR20/CAP/IR/NSP10 120 15 Narrow Spot C, CC-8 4000 600 5000 10 31/4
4,11,12
14166 40PAR20/CAP/IR/NFL30 120 15 Narrow Spot C, CC-8 4000 600 1300 30 31/4
4,11,12
14130 40PAR20/CAP/IR/WFL40 120 15 Wide Flood C, CC-8 4000 600 1000 40 31/2
4,11,12
CAPSYLITE IR®PAR30
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
40 PAR30 E26 Med 13968 40PAR30/CAP/IR/NSP9 120 15 Narrow Spot C, CC-8 4000 680 8800 9 35/8
4,11,12
13969 40PAR30/CAP/IR/NFL25 120 15 Narrow C, CC-8 4000 680 2300 25 35/8
4,11,12 Flood
13970 40PAR30/CAP/IR/FL40 120 15 Flood C, CC-8 4000 680 1300 40 35/8
4,11,12
50 PAR30 E26 Med 14355 50PAR30/CAP/IR/NSP9 120 15 Narrow Spot C, CC-8 3000 900 13000 9 35/8
4,11,12
14109 50PAR30/CAP/IR/NSP9 130 15 Narrow Spot C, CC-8 3000 900 13000 9 35/8
1,4,11,12
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
14354 50PAR30/CAP/IR/NFL25 120 15 Narrow C, CC-8 3000 900 2900 25 35/8
4,11,12 Flood
MR16 PAR20 PAR30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
40
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
INFRARED CONSERVING HALOGEN
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR30 E26 Med 14132 50PAR30/CAP/IR/NFL25 130 15 Narrow C, CC-8 3000 900 2900 25 35/8
1,4,11,12 Flood
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
14714 50PAR30/CAP/IR/FL40 120 15 Flood C, CC-8 3000 900 1400 40 35/8
4,11,12
14131 50PAR30/CAP/IR/FL40 130 15 Flood C, CC-8 3000 900 1400 40 35/8
1,4,11,12
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
CAPSYLITE IR®PAR38
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR38 E26 Med Skt 14136 50PAR38/CAP/IR/SP9 120 15 Spot C, CC-8 3000 850 14000 9 55/16
4,11,12,13
14124 50PAR38/CAP/IR/SP9 130 15 Spot C, CC-8 3000 850 14000 9 55/16
1,4,11,12,13
@ 120 volts, approximate 44 watts, 650 lumens, 6000 hours.
14138 50PAR38/CAP/IR/NFL25 120 15 Narrow C, CC-8 3000 850 3000 25 55/16
4,11,12,13 Flood
14125 50PAR38/CAP/IR/NFL25 130 15 Narrow C, CC-8 3000 850 3000 25 55/16
1,4,11,12,13 Flood
@ 120 volts, approximate 44 watts, 650 lumens, 6000 hours.
55 PAR38 E26 Med Skt 14126 55PAR38/CAP/IR/XP/SP9 120 15 Spot C, CC-8 6000 800 14000 9 55/16
4,11,12,13
14127 55PAR38/CAP/IR/XP/FL30 120 15 Flood C, CC-8 6000 800 2500 30 55/16
4,11,12,13
60 PAR38 E26 Med Skt 14485 60PAR38/CAP/IR/SP9 120 15 Spot C, CC-8 3000 1110 20000 9 55/16
4,11,12,13
14716 60PAR38/CAP/IR/SP9 130 15 Spot C, CC-8 3000 1110 20000 9 55/16
1,4,11,12,13
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
14360 60PAR38/CAP/IR/WSP12 120 15 Wide Spot C, CC-8 3000 1110 12000 12 55/16
4,11,12,13
14442 60PAR38/CAP/IR/NFL25 120 15 Narrow C, CC-8 3000 1110 5000 25 55/16
4,11,12,13 Flood
14466 60PAR38/CAP/IR/FL30 120 15 Flood C, CC-8 3000 1110 3600 30 55/16
4,11,12,13
14715 60PAR38/CAP/IR/FL30 130 15 Flood C, CC-8 3000 1110 3600 30 55/16
1,4,11,12,13
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
80 PAR38 E26 Med Skt 14347 80PAR38/CAP/IR/SP10 120 12 Spot C, CC-8 3000 1500 25000 10 55/16
4,12,13
14327 80PAR38/CAP/IR/FL25 120 12 Flood C, CC-8 3000 1500 5500 25 55/16
4,12,13
100 PAR38 E26 Med Skt 14324 100PAR38/CAP/IR/SP10 120 12 Spot C, CC-8 3000 2070 29000 10 55/16
4,12,13
14319 100PAR38/CAP/IR/NFL25 120 12 Narrow C, CC-8 3000 2070 6300 25 55/16
4,12,13 Flood
14311 100PAR38/CAP/IR/FL40 120 12 Flood C, CC-8 3000 2070 3400 40 55/16
4,12,13
PAR30 PAR38
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
41
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
DAYLIGHT PLUS™ PAR
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR20 E26 Med 15226 50PAR20/DAY/NFL/RP 120 6 Narrow C, CC-8 2000 460 1000 30 31/8
12 Flood
PAR30LN E26 Med 15227 50PAR30LN/DAY/WFL/RP 120 6 Wide Flood C, CC-8 2000 580 550 50 45/8
12,15
PAR38 E26 Med Skt 15229 50PAR38/DAY/FL/RP 120 6 Flood C, CC-8 2000 560 1550 30 55/16
12
60 PAR38 E26 Med Skt 15252 60PAR38/CAP/DAY/SP9 120 15 Spot C, CC-8 2500 725 13500 9 55/16
12
15251 60PAR38/CAP/DAY/FL30 120 15 Flood C, CC-8 2500 725 2150 30 55/16
12
75 PAR30LN E26 Med 15228 75PAR30LN/DAY/WFL/RP 120 6 Wide Flood C, CC-8 2000 1000 1000 50 45/8
12,15
PAR38 E26 Med Skt 15230 75PAR38/DAY/FL/RP 120 6 Flood C, CC-8 2000 960 2800 30 55/16
12
CAPSYLITE®PAR14
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
35 PAR14 E26 Med 14553 12,16 35PAR14/CAP/FL50/RP 120 6 Flood C, CC-8 2000 300 85 50 27/16
DESIGNER 16®- CAPSYLITE®PAR16
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR16 GU10 59020 50PAR16/HAL/GU10/FL/CLAM 120 6 Flood C, CC-2V 1000 400 640 40 21/4
59024 50PAR16/CAP/GU10/FL40 120 10 Flood C, CC-2V 1000 400 640 40 21/4
60 PAR16 E26 Med 59037 12,16 60PAR16/HAL/NSP10/RP 120 6 Narrow Spot C, CC-8 2000 650 5000 10 27/8
59032 12,16 60PAR16/CAP/NSP10 120 15 Narrow Spot C, CC-8 2000 650 5000 10 27/8
59040 1,12,16 60PAR16/CAP/NSP10 130 15 Narrow Spot C, CC-8 2000 650 5000 10 27/8
@ 120 volts, approximate 53 watts, 495 lumens, 4000 hours
59031 12,16 60PAR16/HAL/NFL30/RP 120 6 Narrow C, CC-8 2000 650 1300 30 27/8
Flood
59030 12,16 60PAR16/CAP/NFL30 120 15 Narrow C, CC-8 2000 650 1300 30 27/8
Flood
59038 1,12,16 60PAR16/CAP/NFL30 130 15 Narrow C, CC-8 2000 650 1300 30 27/8
Flood
@ 120 volts, approximate 53 watts, 495 lumens, 4000 hours
75 PAR16 E26 Med 59035 12,16 75PAR16/HAL/NSP10/RP 120 6 Narrow Spot C, CC-8 2000 900 7500 10 27/8
59036 12,16 75PAR16/CAP/NSP10 120 15 Narrow Spot C, CC-8 2000 900 7500 10 27/8
59044 1,12,16 75PAR16/CAP/NSP10 130 15 Narrow Spot C, CC-8 2000 900 7500 10 27/8
@ 120 volts, approximate 66 watts, 685 lumens, 4000 hours
59033 12,16 75PAR16/HAL/NFL30/RP 120 6 Narrow C, CC-8 2000 900 1900 30 27/8
Flood
59034 12,16 75PAR16/CAP/NFL30 120 15 Narrow C, CC-8 2000 900 1900 30 27/8
Flood
59042 1,12,16 75PAR16/CAP/NFL30 130 15 Narrow C, CC-8 2000 900 1900 30 27/8
Flood
@ 120 volts, approximate 66 watts, 685 lumens, 4000 hours
PAR20 PAR30LN PAR38 PAR14 PAR16 GU10 PAR16
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
42
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
CAPSYLITE IR®PAR20
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
40 PAR20 E26 Med 14164 40PAR20/CAP/IR/NSP10 120 15 Narrow Spot C, CC-8 4000 600 5000 10 31/4
4,11,12
14166 40PAR20/CAP/IR/NFL30 120 15 Narrow Spot C, CC-8 4000 600 1300 30 31/4
4,11,12
14130 40PAR20/CAP/IR/WFL40 120 15 Wide Flood C, CC-8 4000 600 1000 40 31/2
4,11,12
CAPSYLITE®PAR20
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
35 PAR20 E26 Med 14467 35PAR20/CAP/SPL/NSP10 120 15 Narrow Spot C, CC-8 2500 360 3000 10 31/4
11,12
14460 35PAR20/CAP/SPL/NSP10 130 15 Narrow Spot C, CC-8 2500 360 3000 10 31/4
1,11,12
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
14464 35PAR20/CAP/SPL/NFL30 120 15 Narrow C, CC-8 2500 360 800 30 31/4
11,12 Flood
14459 35PAR20/CAP/SPL/NFL30 130 15 Narrow C, CC-8 2500 360 800 30 31/4
1,11,12 Flood
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
14506 35PAR20/CAP/SPL/WFL40 120 15 Wide Flood C, CC-8 2500 360 500 40 31/8
11,12
14461 35PAR20/CAP/SPL/WFL40 130 15 Wide Flood C, CC-8 2500 360 500 40 31/8
1,11,12
@ 120 volts, approximate 31 watts, 275 lumens, 5000 hours
50 PAR20 E26 Med 14500 50PAR20/HAL/SPL/NSP10 120 15 Narrow Spot C, CC-8 2500 550 4600 10 31/4
11,12
14528 50PAR20/CAP/SPL/NSP10 130 15 Narrow Spot C, CC-8 2500 550 4600 10 31/4
1,11,12
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
14173 50PAR20/HAL/SPL/NFL30/RP 120 6 Narrow C, CC-8 2500 550 1200 30 31/4
11,12 Flood
14502 50PAR20/HAL/SPL/NFL30 120 15 Narrow C, CC-8 2500 550 1200 30 31/4
11,12 Flood
14529 50PAR20/CAP/SPL/NFL30 130 15 Narrow C, CC-8 2500 550 1200 30 31/4
1,11,12 Flood
@ 120 volts, approximate 44 watts, 420 lumens, 5000 hours
14700 50PAR20/CAP/SPL/WFL40 120 15 Wide Flood C, CC-8 2500 550 900 40 31/8
11,12
CAPSYLITE IR®PAR30
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
40 PAR30 E26 Med 13968 40PAR30/CAP/IR/NSP9 120 15 Narrow Spot C, CC-8 4000 680 8800 9 35/8
4,11,12
13969 40PAR30/CAP/IR/NFL25 120 15 Narrow C, CC-8 4000 680 2300 25 35/8
4,11,12 Flood
13970 40PAR30/CAP/IR/FL40 120 15 Flood C, CC-8 4000 680 1300 40 35/8
4,11,12
50 PAR30 E26 Med 14355 50PAR30/CAP/IR/NSP9 120 15 Narrow Spot C, CC-8 3000 900 13000 9 35/8
4,11,12
14109 50PAR30/CAP/IR/NSP9 130 15 Narrow Spot C, CC-8 3000 900 13000 9 35/8
1,4,11,12
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
PAR20 PAR30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
43
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR30 E26 Med 14354 50PAR30/CAP/IR/NFL25 120 15 Narrow C, CC-8 3000 900 2900 25 35/8
4,11,12 Flood
14132 50PAR30/CAP/IR/NFL25 130 15 Narrow C, CC-8 3000 900 2900 25 35/8
1,4,11,12 Flood
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
14714 50PAR30/CAP/IR/FL40 120 15 Flood C, CC-8 3000 900 1400 40 35/8
4,11,12
14131 50PAR30/CAP/IR/FL40 130 15 Flood C, CC-8 3000 900 1400 40 35/8
1,4,11,12
@ 120 volts, approximate 44 watts, 690 lumens, 6000 hours.
CAPSYLITE®PAR30
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR30 E26 Med 14526 50PAR30/CAP/SPL/NSP9 120 15 Narrow Spot C, CC-8 2500 660 8800 9 35/8
11,12
14530 50PAR30/CAP/SPL/NSP9 130 15 Narrow Spot C, CC-8 2500 660 8800 9 35/8
1,11,12
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14527 50PAR30/CAP/SPL/NFL25 120 15 Narrow C, CC-8 2500 660 2300 25 35/8
11,12 Flood
14531 50PAR30/CAP/SPL/NFL25 130 15 Narrow C, CC-8 2500 660 2300 25 35/8
1,11,12 Flood
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14710 50PAR30/HAL/SPL/FL40 120 15 Flood C, CC-8 2500 660 1300 40 35/8
11,12
14533 50PAR30/CAP/SPL/FL40 130 15 Flood C, CC-8 2500 660 1300 40 35/8
1,11,12
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
60 PAR30 E26 Med 14332 60PAR30/CAP/SPL/NSP9 120 15 Narrow Spot C, CC-8 3000 860 12000 9 35/8
11,12
14333 60PAR30/CAP/SPL/NFL25 120 15 Narrow C, CC-8 3000 860 2775 25 35/8
11,12 Flood
14090 60PAR30/CAP/SPL/NFL25 130 15 Narrow C, CC-8 3000 860 2775 25 35/8
1,11,12 Flood
@ 120 volts, approximate 53 watts, 660 lumens, 6000 hours.
14084 60PAR30/CAP/SPL/FL40 130 15 Flood C, CC-8 3000 860 1550 40 35/8
1,11,12
@ 120 volts, approximate 53 watts, 660 lumens, 6000 hours.
75 PAR30 E26 Med 14604 75PAR30/CAP/SPL/NSP9 120 15 Narrow Spot C, CC-8 2500 1130 15400 9 35/8
11,12
14628 75PAR30/CAP/SPL/NSP9 130 15 Narrow Spot C, CC-8 2500 1130 15400 9 35/8
1,11,12
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14603 75PAR30/CAP/SPL/NFL25 120 15 Narrow C, CC-8 2500 1130 4000 25 35/8
11,12 Flood
14627 75PAR30/CAP/SPL/NFL25 130 15 Narrow C, CC-8 2500 1130 4000 25 35/8
1,11,12 Flood
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14606 75PAR30/CAP/SPL/FL40 120 15 Flood C, CC-8 2500 1130 2100 40 35/8
11,12
14629 75PAR30/CAP/SPL/FL40 130 15 Flood C, CC-8 2500 1130 2100 40 35/8
1,11,12
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
PAR30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
44
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
CAPSYLITE®PAR30 LONG NECK
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
35 PAR30LN E26 Med 14759 35PAR30LN/CAP/SPL/NSP9 120 15 Narrow Spot C, CC-8 2500 450 5700 9 45/8
11,12,15
14764 35PAR30LN/CAP/SPL/WFL50 120 15 Wide Flood C, CC-8 2500 450 450 50 45/8
11,12,15
50 PAR30LN E26 Med 14509 50PAR30LN/CAP/SPL/NSP9 120 15 Narrow Spot C, CC-8 2500 660 8800 9 45/8
11,12,15,19
14482 50PAR30LN/CAP/SPL/NSP9 130 15 Narrow Spot C, CC-8 2500 660 8800 9 45/8
1,11,12,15,19
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14822 50PAR30LN/CAP/SPL/NFL/RP 120 6 Narrow C, CC-8 2500 660 2300 25 45/8
11,12,15,19 Flood
14520 50PAR30LN/CAP/SPL/NFL25 120 15 Narrow C, CC-8 2500 660 2300 25 45/8
11,12,15,19 Flood
14478 50PAR30LN/CAP/SPL/NFL25 130 15 Narrow C, CC-8 2500 660 2300 25 45/8
1,11,12,15,19 Flood
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
14536 50PAR30LN/CAP/SPL/WFL/RP 120 6 Wide Flood C, CC-8 2500 660 660 50 45/8
11,12,15,19
14537 50PAR30LN/CAP/SPL/WFL50 120 15 Wide Flood C, CC-8 2500 660 660 50 45/8
11,12,15,19
14486 50PAR30LN/CAP/SPL/WFL50 130 15 Wide Flood C, CC-8 2500 660 660 50 45/8
1,11,12,15,19
@ 120 volts, approximate 44 watts, 500 lumens, 5000 hours
75 PAR30LN E26 Med 14786 75PAR30LN/CAP/SPL/NSP9 120 15 Narrow Spot C, CC-8 2500 1130 15400 9 45/8
11,12,15
14777 75PAR30LN/CAP/SPL/NSP9 130 15 Narrow Spot C, CC-8 2500 1130 15400 9 45/8
1,11,12,15
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14824 75PAR30LN/CAP/SPL/NFL/RP 120 6 Narrow C, CC-8 2500 1130 4000 25 45/8
11,12,15 Flood
14769 75PAR30LN/CAP/SPL/NFL25 120 15 Narrow C, CC-8 2500 1130 4000 25 45/8
11,12,15 Flood
14778 75PAR30LN/CAP/SPL/NFL25 130 15 Narrow C, CC-8 2500 1130 4000 25 45/8
1,11,12,15 Flood
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
14823 75PAR30LN/CAP/SPL/WFL/RP 120 6 Wide Flood C, CC-8 2500 1130 1100 50 45/8
11,12,15
14768 75PAR30LN/CAP/SPL/WFL50 120 15 Wide Flood C, CC-8 2500 1130 1100 50 45/8
11,12,15
14785 75PAR30LN/CAP/SPL/WFL50 130 15 Wide Flood C, CC-8 2500 1130 1100 50 45/8
1,11,12,15
@ 120 volts, approximate 66 watts, 860 lumens, 5000 hours
CAPSYLITE®PAR36
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
36 PAR36 55100 15 36PAR36/CAP/VNSP5 12 12 Very C, C-8 4000 500 17000 5 23/4
Narrow Spot
55090 15 36PAR36/CAP/NSP13 12 12 Narrow Spot C, C-8 4000 500 3500 13 23/4
55091 15 36PAR36/CAP/WFL32 12 12 Wide Flood C, C-8 4000 500 1000 32 23/4
50 PAR36 55118 15 50PAR36/CAP/NSP6 12 12 Narrow Spot C, C-8 4000 700 25000 6 23/4
PAR30LN PAR36
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
45
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
CAPSYLITE IR®PAR38
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR38 E26 Med Skt 14136 50PAR38/CAP/IR/SP9 120 15 Spot C, CC-8 3000 850 14000 9 55/16
4,11,12,13
14124 50PAR38/CAP/IR/SP9 130 15 Spot C, CC-8 3000 850 14000 9 55/16
1,4,11,12,13
@ 120 volts, approximate 44 watts, 650 lumens, 6000 hours.
14138 50PAR38/CAP/IR/NFL25 120 15 Narrow C, CC-8 3000 850 3000 25 55/16
4,11,12,13 Flood
14125 50PAR38/CAP/IR/NFL25 130 15 Narrow C, CC-8 3000 850 3000 25 55/16
1,4,11,12,13 Flood
@ 120 volts, approximate 44 watts, 650 lumens, 6000 hours.
55 PAR38 E26 Med Skt 14126 55PAR38/CAP/IR/XP/SP9 120 15 Spot C, CC-8 6000 800 14000 9 55/16
4,11,12,13
14127 55PAR38/CAP/IR/XP/FL30 120 15 Flood C, CC-8 6000 800 2500 30 55/16
4,11,12,13
60 PAR38 E26 Med Skt 14485 60PAR38/CAP/IR/SP9 120 15 Spot C, CC-8 3000 1110 20000 9 55/16
4,11,12,13
14716 60PAR38/CAP/IR/SP9 130 15 Spot C, CC-8 3000 1110 20000 9 55/16
1,4,11,12,13
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
14360 60PAR38/CAP/IR/WSP12 120 15 Wide Spot C, CC-8 3000 1110 12000 12 55/16
4,11,12,13
14442 60PAR38/CAP/IR/NFL25 120 15 Narrow C, CC-8 3000 1110 5000 25 55/16
4,11,12,13 Flood
14466 60PAR38/CAP/IR/FL30 120 15 Flood C, CC-8 3000 1110 3600 30 55/16
4,11,12,13
14715 60PAR38/CAP/IR/FL30 130 15 Flood C, CC-8 3000 1110 3600 30 55/16
1,4,11,12,13
@ 120 volts, approximate 53 watts, 845 lumens, 6000 hours.
80 PAR38 E26 Med Skt 14347 80PAR38/CAP/IR/SP10 120 12 Spot C, CC-8 3000 1500 25000 10 55/16
4,12,13
14327 80PAR38/CAP/IR/FL25 120 12 Flood C, CC-8 3000 1500 5500 25 55/16
4,12,13
100 PAR38 E26 Med Skt 14324 100PAR38/CAP/IR/SP10 120 12 Spot C, CC-8 3000 2070 29000 10 55/16
4,12,13
14319 100PAR38/CAP/IR/NFL25 120 12 Narrow C, CC-8 3000 2070 6300 25 55/16
4,12,13 Flood
14311 100PAR38/CAP/IR/FL40 120 12 Flood C, CC-8 3000 2070 3400 40 55/16
4,12,13
CAPSYLITE®PAR38
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
45 PAR38 E26 Med Skt 14590 45PAR38/CAP/SPL/SP9 120 15 Spot C, CC-8 2500 560 10000 9 55/16
11,12,13
14593 45PAR38/CAP/SPL/SP9 130 15 Spot C, CC-8 2500 560 10000 9 55/16
1,11,12,13
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
14589 45PAR38/CAP/SPL/WSP12 120 15 Wide Spot C, CC-8 2500 560 6300 12 55/16
11,12,13
14592 45PAR38/CAP/SPL/WSP12 130 15 Wide Spot C, CC-8 2500 560 6300 12 55/16
1,11,12,13
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
PAR38
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
46
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
45 PAR38 E26 Med Skt 14588 45PAR38/CAP/SPL/FL30 120 15 Flood C, CC-8 2500 560 1500 30 55/16
11,12,13
14591 45PAR38/CAP/SPL/FL30 130 15 Flood C, CC-8 2500 560 1500 30 55/16
1,11,12,13
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
14010 45PAR38/CAP/SPL/WFL50 130 15 Wide Flood C, CC-8 2500 560 700 50 55/16
1,11,12,13
@ 120 volts, approximate 40 watts, 425 lumens, 5000 hours
50 PAR38 E26 Med Skt 15521 50PAR38/HAL/SPL/SP9/RP 120 6 Spot C, CC-8 2500 650 10500 9 55/16
11,12,13
15520 50PAR38/HAL/SPL/FL30/RP 120 6 Flood C, CC-8 2500 650 1850 30 55/16
11,12,13
60 PAR38 E26 Med Skt 14469 60PAR38/CAP/SPL/SP9 120 15 Spot C, CC-8 3000 850 16000 9 55/16
11,12,13
14449 60PAR38/CAP/SPL/SP9 130 15 Spot C, CC-8 3000 850 16000 9 55/16
1,11,12,13
@ 120 volts, approximate 53 watts, 645 lumens, 6000 hours
14423 60PAR38/CAP/SPL/WSP12 120 15 Wide Spot C, CC-8 3000 850 10500 12 55/16
11,12,13
14472 60PAR38/CAP/SPL/NFL25 120 15 Narrow C, CC-8 3000 850 3700 25 55/16
12 Flood
14468 60PAR38/CAP/SPL/FL30 120 15 Flood C, CC-8 3000 850 2500 30 55/16
11,12,13
14448 60PAR38/CAP/SPL/FL30 130 15 Flood C, CC-8 3000 850 2500 30 55/16
1,11,12,13
@ 120 volts, approximate 53 watts, 645 lumens, 6000 hours
75 PAR38 E26 Med Skt 14854 75PAR38/HAL/SPL/SP/RP 120 6 Spot C, CC-8 2500 1060 19200 9 55/16
11,12,13
14514 75PAR38/CAP/SPL/SP9 120 15 Spot C, CC-8 2500 1060 19200 9 55/16
11,12,13
14516 75PAR38/CAP/SPL/SP9 130 15 Spot C, CC-8 2500 1060 19200 9 55/16
1,11,12,13
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
14510 75PAR38/CAP/SPL/WSP12 120 15 Wide Spot C, CC-8 2500 1060 12300 12 55/16
11,12,13
14853 75PAR38/HAL/SPL/FL/RP 120 6 Flood C, CC-8 2500 1060 3150 30 55/16
11,12,13
14513 75PAR38/CAP/SPL/FL30 120 15 Flood C, CC-8 2500 1060 3150 30 55/16
11,12,13
14446 75PAR38/CAP/SPL/FL/CVP 130 6 Flood C, CC-8 2500 1060 3150 30 55/16
1,11,12,13
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
14515 75PAR38/CAP/SPL/FL30 130 15 Flood C, CC-8 2500 1060 3150 30 55/16
1,11,12,13
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
14517 75PAR38/CAP/SPL/WFL50 130 15 Wide Flood C, CC-8 2500 1060 1300 50 55/16
1,11,12,13
@ 120 volts, approximate 66 watts, 805 lumens, 5000 hours
90 PAR38 E26 Med Skt 14586 90PAR38/CAP/SPL/SP9 120 15 Spot C, CC-8 2500 1310 19000 9 55/16
11,12,13
14587 90PAR38/CAP/SPL/SP9 130 15 Spot C, CC-8 2500 1310 19000 9 55/16
1,11,12,13
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14580 90PAR38/CAP/SPL/WSP12 120 15 Wide Spot C, CC-8 2500 1310 14300 12 55/16
11,12,13
PAR38
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
47
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
90 PAR38 E26 Med Skt 14578 90PAR38/CAP/SPL/WSP12 130 15 Wide Spot C, CC-8 2500 1310 14300 12 55/16
1,11,12,13
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14601 90PAR38/CAP/SPL/NFL25 130 15 Narrow C, CC-8 2500 1310 4700 25 55/16
1,11,12,13 Flood
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14579 90PAR38/CAP/SPL/FL30 120 15 Flood C, CC-8 2500 1310 3500 30 55/16
11,12,13
14647 90PAR38/CAP/SPL/FL/CVP 130 6 Flood C, CC-8 2500 1310 3500 30 55/16
1,11,12,13
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14577 90PAR38/CAP/SPL/FL30 130 15 Flood C, CC-8 2500 1310 3500 30 55/16
1,11,12,13
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
14602 90PAR38/CAP/SPL/WFL50 130 15 Wide Flood C, CC-8 2500 1310 1600 50 55/16
1,11,12,13
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
Med Side Prong 14630 90PAR38/CAP/SPL/3WSP12 120 15 Wide Spot C, CC-8 2500 1310 14300 12 55/16
11,12,13
14632 90PAR38/CAP/SPL/3FL30 120 15 Flood C, CC-8 2500 1310 3500 30 55/16
11,12,13
100 PAR38 E26 Med Skt 15522 100PAR38/HAL/SPL/SP9/RP 120 6 Spot C, CC-8 2500 1500 22000 9 55/16
11,12,13
15585 100PAR38/HAL/SPL/FL30/RP 120 6 Flood C, CC-8 2500 1500 4000 30 55/16
11,12,13
106 PAR38 E26 Med Skt 15003 106PAR38/CAP/SPL/SP10 120 15 Spot C, CC-8 2000 1800 22500 10 55/16
11,12,13
15001 106PAR38/CAP/SPL/WFL55 120 15 Wide Flood C, CC-8 2000 1800 2000 55 55/16
11,12,13
120 PAR38 E26 Med Skt 14873 120PAR38/HAL/SPL/SP/XTRA/RP 120 6 Spot C, CC-8 3000 1800 22500 10 55/16
11,12,13
14856 120PAR38/CAP/SPL/SP10 120 15 Spot C, CC-8 3000 1800 22500 10 55/16
11,12,13
14874 120PAR38/CAP/SPL/SP10 130 15 Spot C, CC-8 3000 1800 22500 10 55/16
1,11,12,13
@ 120 volts, approximate 105 watts, 1370 lumens, 6000 hours
14848 120PAR38/CAP/SPL/NFL25 120 15 Narrow C, CC-8 3000 1800 7700 25 55/16
11,12,13 Flood
14576 120PAR38/HAL/SPL/FL/XTRA/RP 120 6 Flood C, CC-8 3000 1800 4600 30 55/16
11,12,13
14855 120PAR38/CAP/SPL/FL30 120 15 Flood C, CC-8 3000 1800 4600 30 55/16
11,12,13
14861 120PAR38/CAP/SPL/FL30 130 15 Flood C, CC-8 3000 1800 4600 30 55/16
1,11,12,13
@ 120 volts, approximate 105 watts, 1370 lumens, 6000 hours
14594 120PAR38/CAP/SPL/WFL55 120 15 Wide Flood C, CC-8 3000 1800 2000 55 55/16
11,12,13
250 PAR38 E26 Med Skt 15526 250PAR38/CAP/SPL/SP10 120 6 Spot C, CC-8 4500 3600 46500 10 55/16
11,13,15,20,21,22
15558 250PAR38/CAP/SPL/FL30 120 6 Flood C, CC-8 4500 3600 9000 30 55/16
11,13,15,20,21,22
PAR38 PAR38
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
48
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
CAPSYLITE®PAR
CAPSYLITE COOL LUX
CAPSYLITE Cool Lux PAR30
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
50 PAR30 E26 Med 14916 50PAR30/CAP/SPL/2NFL25 120 15 Narrow C, CC-8 2500 600 1850 25 35/8
12,13,23 Flood
CAPSYLITE Cool Lux PAR38
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
90 PAR38 E26 Med Skt 14972 90PAR38/CAP/2SP12 120 15 Spot C, CC-8 2500 1260 12000 12 55/16
12,13,23
14971 90PAR38/CAP/SPL/2FL30 120 15 Flood C, CC-8 2500 1260 3750 30 55/16
12,13,23
14973 90PAR38/CAP/SPL/2FL30 130 15 Flood C, CC-8 2500 1260 3750 30 55/16
1,12,13,23
@ 120 volts, approximate 79 watts, 1000 lumens, 5000 hours
LARGE PAR
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
500 PAR56 Ext Mog End Pr 56210 2,24,25 500PAR56Q/NSP 120 12 Narrow Spot C, CC-6 4000 8800 78500 8x15 5
56211 2,24,25 500PAR56Q/MFL 120 12 Medium C, CC-6 4000 8800 40000 11x30 5
Flood
56212 2,24,25 500PAR56Q/WFL 120 12 Wide Flood C, CC-6 4000 8800 19500 20x45 5
1000 PAR64 Ext Mog End Pr 56206 2,24,25 1000PAR64Q/NSP 120 6 Narrow Spot C, CC-6 4000 19400 135000 8x20 6
56207 2,24,25 1000PAR64Q/MFL 120 6 Medium C, CC-6 4000 19400 82000 10x30 6
Flood
56208 2,24,25 1000PAR64Q/WFL 120 6 Wide Flood C, CC-6 4000 19400 23000 20x60 6
CAPSYLITE®G9
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
25 T4 G9 Bipin 57020 13,26,27 25CAPSYLITE/G9/CL 120 20 Clear C, CC-2V 2000 255 7/8111/16
57016 13,26,27 25CAPSYLITE/G9/CL/BL 120 10 Clear C, CC-2V 2000 255 7/8111/16
57021 13,26,27 25CAPSYLITE/G9/F 120 20 Frosted C, CC-2V 2000 230 7/8111/16
57015 13,26,27 25CAPSYLITE/G9/F/BL 120 10 Frosted C, CC-2V 2000 230 7/8111/16
40 T4 G9 Bipin 57022 13,26,27 40CAPSYLITE/G9/CL 120 20 Clear C, CC-2V 2000 510 7/8111/16
57018 13,26,27 40CAPSYLITE/G9/CL/BL 120 10 Clear C, CC-2V 2000 510 7/8111/16
57025 13,26,27 40CAPSYLITE/G9/F 120 20 Frosted C, CC-2V 2000 480 7/8111/16
57017 13,26,27 40CAPSYLITE/G9/F/BL 120 10 Frosted C, CC-2V 2000 480 7/8111/16
60 T4 G9 Bipin 57023 13,26,27 60CAPSYLITE/G9/CL 120 20 Clear C, CC-2V 2000 830 11/16 2
57014 13,26,27 60CAPSYLITE/G9/CL/BL 120 10 Clear C, CC-2V 2000 830 11/16 2
57024 13,26,27 60CAPSYLITE/G9/F 120 20 Frosted C, CC-2V 2000 790 11/16 2
57019 13,26,27 60CAPSYLITE/G9/F/BL 120 10 Frosted C, CC-2V 2000 790 11/16 2
PAR30 PAR38 PAR56 PAR64 G9
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
49
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
SUPER Q - SINGLE END QUARTZ
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
75 T3 E10 58876 2,28 75Q/CL/MS 28 12 Clear C, CC-6 2000 1400 17/823/8
E11 Mini Can 58884 2,28 75Q/CL/MC/RP 120 6 Clear C, CC-8 2000 1400 17/829/16
100 T4 DC Bayonet 18858 2,28 100Q/CL/DC/64485 120 10 Clear C, CC-2V 2000 1600 23/16 33/8
58755 2,28 100Q/CL/DC(ESR) 120 12 Clear C, CC-2V 1000 1900 13/827/16
58757 2,28 100Q/DC(ETD) 120 12 Frosted C, CC-2V 1000 1750 13/827/16
58732 2,28 100Q/CL/DC 130 12 Clear C, CC-2V 1000 1900 13/827/16
E11 Mini Can 58817 2,28 100Q/CL/MC/RP(ESN) 120 6 Clear C, CC-8 1000 1800 13/829/16
58761 2,28 100Q/CL/MC(ESN) 120 12 Clear C, CC-2V 1000 1800 13/823/4
58760 2,28 100Q/CL/MC 130 12 Clear C, CC-2V 1000 1800 13/823/4
150 T4 DC Bayonet 58741 2,28 150Q/CL/DC(ETC) 120 12 Clear C, CC-8 2000 2800 11/223/4
58742 2,28 150Q/CL/DC/1(ESP) 120 12 Clear C, CC-2V 1000 2400 13/827/16
58748 2,28 150Q/CL/DC 130 12 Clear C, CC-2V 1000 2800 13/823/4
58737 2,28 150Q/DC(ETF) 120 12 Frosted C, CC-8 2000 2700 11/223/4
E11 Mini Can 58731 2,28 150Q/CL/MC/RP(ETG) 120 6 Clear C, CC-8 2000 2800 13/83
58738 2,28 150Q/CL/MC(ESL) 120 12 Clear C, CC-2V 1000 2800 13/823/4
58735 2,28 150Q/CL/MC/2(ETG) 120 12 Clear C, CC-8 2000 2800 11/23
58733 2,28 150Q/CL/MC 130 12 Clear C, CC-2V 1000 2800 13/823/4
58736 2,28 150Q/MC(ETH) 120 12 Frosted C, CC-8 2000 2700 11/23
250 T4 DC Bayonet 58720 2,28 250Q/CL/DC(ESS) 120 12 Clear C, CC-8 2000 5000 15/831/8
58753 2,28 250Q/DC(ETB) 120 12 Frosted C, CC-8 2000 4850 15/831/8
58754 2,28 250Q/DC 130 12 Frosted C, CC-8 2000 4850 15/831/8
E11 Mini Can 58773 2,28 250Q/CL/MC/RP(EHT) 120 6 Clear C, CC-8 2000 5000 15/831/8
58762 2,28 250Q/CL/MC(EHT) 120 12 Clear C, CC-8 2000 5000 15/831/8
58764 2,28 250Q/CL/MC 130 12 Clear C, CC-8 2000 5000 15/831/8
58763 2,28 250Q/MC(ESM) 120 12 Frosted C, CC-8 2000 4850 15/831/8
58765 2,28 250Q/MC 130 12 Frosted C, CC-8 2000 4850 15/831/8
500 T4 E11 Mini Can 58766 2,28 500Q/CL/MC(EVR) 120 12 Clear C, CC-8 2000 10450 2 33/4
58756 2,28 500Q/CL/MC(EYW) 130 12 Clear C, CC-8 2000 10000 2 33/4
58767 2,28 500Q/MC(EYX) 120 12 Frosted C, CC-8 2000 10100 2 33/4
58768 2,28 500Q/MC(EYV) 130 12 Frosted C, CC-8 2000 10000 2 33/4
750 T4 E11 Mini Can 58769 2,28 750Q/CL/MC(EYT) 120 12 Clear C, CC-8 500 16500 2 33/4
DOUBLE END
DOUBLE END QUARTZ
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
100 T3 RSC 58887 2,28 100T3Q/S/CL/RP 120 6 Clear C, C-8 2000 1600 31/8
58887 2,28 100T3Q/CL/RP 120 12 Clear C, C-8 2000 1600 31/8
150 T3 RSC 58885 2,28 150T3Q/CL/RP 120 6 Clear C, C-8 1500 2250 411/16
58886 2,28 150T3Q/S/CL/RP 120 6 Clear C, CC-8 2000 2400 31/8
T3, T4 T3
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
50
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
DOUBLE END
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
150 T3 RSC 58915 2,28 150T3/Q/S/CL 120 12 Clear C, CC-8 2000 2400 31/8
200 T3 RSC 58917 2,28 200T3Q/CL 120 12 Clear C, CC-8 2000 3350 411/16
300 T3 RSC 58920 2,28 300T3Q/CL/RP(EHM) 120 6 Clear C, C-8 2000 9300 411/16
58923 2,20 300T3Q/CL(EHM) 120 12 Clear C, C-8 2000 6000 411/16
58919 2,20 300T3Q/CL 130 12 Clear C, C-8 2000 5950 411/16
500 T3 RSC 58865 2,28 500T3Q/CL/RP(FCL) 120 6 Clear C, CC-8 2000 8750 411/16
58883 2,28 500T3Q(FCZ) 120 12 Frosted C, C-8 2000 9300 411/16
58856 2,20 500T3Q/CL(FCL) 120 12 Clear C, CC-8 2000 8750 411/16
58902 2,20 500T3Q/CL 130 12 Clear C, C-8 2000 8750 411/16
1000 T3 RSC 58948 2,28 1000T3Q/CL 240 12 Clear C, C-8 2000 21500 101/16
1500 T3 RSC 58859 2,28 1500T3Q/CL208V 208 12 Clear C, C-8 2000 33000 101/16
58857 2,28 1500T3Q/CL 240 12 Clear C, C-8 2000 33000 101/16
58858 2,28 1500T3Q/CL277V 277 12 Clear C, C-8 2000 33000 101/16
BI-PIN
STARLITE BI-PIN
UV filter quartz capsule with axial filament.
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
10 T3 G4 58692 27,29 10T3Q/CL/AX6V 640Clear C, AX 4000 130 7/811/4
58691 27,29 10T3Q/CL/AX 12 40 Clear C, AX 4000 130 7/811/4
20 T3 G4 58694 27,29 20T3Q/CL/AX 12 40 Clear C, AX 4000 320 7/811/4
T4 GY6.35 58663 27,29 20T4Q/CL/AX 12 40 Clear C, AX 4000 320 11/813/4
35 T4 GY6.35 58672 27,29 35T4Q/CL/AX 12 40 Clear C, AX 4000 600 11/813/4
50 T4 GY6.35 58676 27,29 50T4Q/CL/AX 12 40 Clear C, AX 4000 910 11/813/4
75 T4 GY6.35 58680 27,29 75T4Q/CL/AX 12 40 Clear C, AX 4000 1450 11/813/4
90 T4 GY6.35 58684 27,29 90T4Q/CL/AX 12 40 Clear C, AX 4000 1800 11/813/4
STANDARD BI-PIN
UV filter quartz capsule with transverse filament.
Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
5T3 G4 58652 27,28,30 5T3Q/CL 12 40 Clear C, TR 2000 60 7/811/4
58651 27,28,31 5T3Q/F 12 40 Frosted C, TR 2000 55 7/811/4
10 T3 G4 58650 27,28,30 10T3Q/CL/RP 12 6 Clear C, TR 2000 140 7/811/4
58658 27,28,30 10T3Q/CL 12 40 Clear C, TR 2000 140 7/811/4
58656 27,28,31 10T3Q/F 12 40 Frosted C, TR 2000 130 7/811/4
20 T3 G4 58655 27,28,30 20T3Q/CL/RP 12 6 Clear C, TR 2000 320 7/811/4
58661 27,28,30 20T3Q/CL 12 40 Clear C, TR 2000 320 7/811/4
50 T4 GY6.35 58660 27,28,30 50T4Q/CL/RP 12 6 Clear C, TR 2000 910 11/813/4
58675 27,28,30 50T4Q/CL 12 40 Clear C, TR 2000 910 11/813/4
75 T4 GY6.35 58665 27,28,30 75T4Q/CL/RP 12 6 Clear C, TR 2000 1200 11/813/4
T3 T3, T4
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
51
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
BI-PIN
BI-PIN 24VOLT
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
20 T3 G4 58662 32,33 20T3Q/CL/24V 24 40 Clear C, AX 1000 320 7/811/4
50 T4 GY6.35 58678 32,33 50T4Q/CL/AX/24V 24 40 Clear C, AX 2000 850 11/813/4
TRU-AIM®
TRU-AIM IR MR16
UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on the lamp capsule.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR16 GU5.3 58531 4,5,6, 20MR16/IR/SP10/C 12 20 Spot C, AX 4000 6000 10 13/4
7,8
58532 4,5,6, 20MR16/IR/NFL25/C 12 20 Narrow C, AX 4000 2300 25 13/4
7,8 Flood
58533 4,5,6, 20MR16/IR/FL40/C 12 20 Flood C, AX 4000 1000 40 13/4
7,8
58838 4,5,6, 20MR16/IR/WFL60/C 12 20 Wide Flood C, AX 4000 450 60 13/4
7,8
37 MR16 GU5.3 58641 4,5,6, 37MR16/IR/SP10/C 12 20 Spot C, AX 4000 12500 10 13/4
8,10
58634 4,5,6, 37MR16/IR/NFL25/C 12 20 Narrow C, AX 4000 4400 25 13/4
8,10 Flood
58633 4,5,6, 37MR16/IR/FL40/C 12 20 Flood C, AX 4000 2200 40 13/4
8,10
58837 4,5,6, 37MR16/IR/WFL60/C 12 20 Wide Flood C, AX 4000 1100 60 13/4
8,10
50 MR16 GU5.3 54175 4,5,6, 50MR16/IR/SP10/C 12 20 Spot C, AX 4000 15000 10 13/4
8,10
54174 4,5,6, 50MR16/IR/NFL25/C 12 20 Narrow C, AX 4000 5700 25 13/4
8,10 Flood
54173 4,5,6, 50MR16/IR/FL40/C 12 20 Flood C, AX 4000 2850 40 13/4
8,10
54237 4,5,6, 50MR16/IR/WFL60/C 12 20 Wide Flood C, AX 4000 1430 60 13/4
8,10
TRU-AIM TITAN®MR16
UV Filter capsule with axial filament in constant color, hard coated dichroic reflector.
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR16 GU5.3 58550 5,7,32, 20MR16/T/NSP10(ESX) 12 10 Narrow Spot C, AX 4000 5000 10 13/4
34
58551 5,7,32, 20MR16/T/FL40(BAB) 12 10 Flood C, AX 4000 700 40 13/4
34
58562 5,7,32, 20MR16/T/VWFL60 12 10 Very Wide C, AX 4000 350 60 13/4
34 Flood
35 MR16 GU5.3 58558 5,10,32, 35MR16/T/NSP10(FRB) 12 10 Narrow Spot C, AX 4000 8300 10 13/4
34
58547 5,10,32, 35MR16/T/NFL25 12 10 Narrow C, AX 4000 3100 25 13/4
34 Flood
T3, T4 MR16
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
52
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
TRU-AIM TITAN® MR16
UV Filter capsule with axial filament in constant color, hard coated dichroic reflector.
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
35 MR16 GU5.3 58557 5,10,32, 35MR16/T/FL40(FMW) 12 10 Flood C, AX 4000 1250 40 13/4
34
58552 5,10,32, 35MR16/T/VWFL60 12 10 Very Wide C, AX 4000 650 60 13/4
34 Flood
50 MR16 GU5.3 58556 5,10,32, 50MR16/T/NSP10(EXT) 12 10 Narrow Spot C, AX 4000 11500 10 13/4
34
58555 5,10,32, 50MR16/T/NFL25(EXZ) 12 10 Narrow C, AX 4000 3200 25 13/4
34 Flood
58554 5,10,32, 50MR16/T/FL40(EXN) 12 10 Flood C, AX 4000 2000 40 13/4
34
58553 5,10,32, 50MR16/T/VWFL60(FNV) 12 10 Very Wide C, AX 4000 1000 60 13/4
34 Flood
65 MR16 GU5.3 58566 5,10,32, 65MR16/T/NSP10(FPA) 12 10 Narrow Spot C, AX 4000 14000 10 13/4
34
58567 5,10,32, 65MR16/T/NFL25 12 10 Narrow C, AX 4000 4000 25 13/4
34 Flood
58571 5,10,32, 65MR16/T/FL40(FPB) 12 10 Flood C, AX 4000 2100 40 13/4
34
58572 5,10,32, 65MR16/T/VWFL60 12 10 Very Wide C, AX 4000 1050 60 13/4
34 Flood
TRU-AIM BRILLIANT®MR16
UV Filter capsule with axial filament in constant color, aluminized reflector.
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR16 GU5.3 58589 5,7,32, 20MR16/B/NSP8 12 10 Narrow Spot C, AX 4000 4650 8 13/4
35
58590 5,7,32, 20MR16/B/FL35 12 10 Flood C, AX 4000 625 35 13/4
35
35 MR16 GU5.3 58591 5,10,32, 35MR16/B/NSP10 12 10 Narrow Spot C, AX 4000 8700 10 13/4
35
58593 5,10,32, 35MR16/B/FL35 12 10 Flood C, AX 4000 1300 35 13/4
35
50 MR16 GU5.3 58594 5,10,32, 50MR16/B/NSP11 12 10 Narrow Spot C, AX 4000 10500 11 13/4
35
58595 5,10,32, 50MR16/B/NFL25 12 10 Narrow C, AX 4000 3000 25 13/4
35 Flood
58596 5,10,27, 50MR16/B/FL35 12 10 Flood C, AX 4000 1900 35 13/4
35,36
65 MR16 GU5.3 58559 5,10,32, 65MR16/B/NSP10 12 10 Narrow Spot C, AX 4000 12500 10 13/4
35
58561 5,10,32, 65MR16/B/NFL25 12 10 Narrow C, AX 4000 3600 25 13/4
35 Flood
58560 5,10,32, 65MR16/B/FL35 12 10 Flood C, AX 4000 2100 35 13/4
35
MR16
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
53
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
TRU-AIM®
TRU-AIM®MR16
UV Filter capsule with axial filament in dichroic reflector.
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR16 GU5.3 58576 5,7,32, 20MR16/NSP/RP(ESX) 12 6 Narrow Spot C, AX 4000 6000 8 13/4
37
54201 5,7,32, 20MR16/NSP8(ESX) 12 20 Narrow Spot C, AX 4000 6000 8 13/4
37
58646 5,7,32, 20MR16/FL/RP(BAB) 12 6 Flood C, AX 4000 700 40 13/4
37
54200 5,7,32, 20MR16/FL40(BAB) 12 20 Flood C, AX 4000 700 40 13/4
37
35 MR16 GU5.3 54204 5,10,32, 35MR16/NSP8(FRB) 12 20 Narrow Spot C, AX 4000 11000 8 13/4
37
58602 5,10,32, 35MR16/SP20(FRA) 12 10 Spot C, AX 4000 2800 20 13/4
37
54203 5,10,32, 35MR16/FL40(FMW) 12 20 Flood C, AX 4000 1400 40 13/4
37
50 MR16 GU5.3 58629 5,10,32, 50MR16/NSP/RP(EXT) 12 6 Narrow Spot C, AX 4000 11000 12 13/4
37
54208 5,10,32, 50MR16/NSP12(EXT) 12 20 Narrow Spot C, AX 4000 11000 12 13/4
37
54205 5,10,32, 50MR16/NFL25(EXZ) 12 20 Narrow C, AX 4000 3200 25 13/4
37 Flood
58983 5,10,32, 50MR16/FL/RP(EXN) 12 6 Flood C, AX 4000 2000 40 13/4
37
54207 5,10,32, 50MR16/FL40(EXN) 12 20 Flood C, AX 4000 2000 40 13/4
37
54206 5,10,32, 50MR16/VWFL60(FNV) 12 20 Very Wide C, AX 4000 1200 60 13/4
37 Flood
65 MR16 GU5.3 58563 5,10,32, 65MR16/NSP10(FPA) 12 10 Narrow Spot C, AX 4000 14000 10 13/4
37
58565 5,10,32, 65MR16/NFL25(FPC) 12 10 Narrow C, AX 4000 4000 25 13/4
37 Flood
58564 5,10,32, 65MR16/FL40(FPB) 12 10 Flood C, AX 4000 2100 40 13/4
37
TRU-AIM®MR11
UV Filter capsule with axial filament in dichroic reflector.
A suitable protective shield, screening technique or both shall be used to protect people and surroundings from the possibility of a lamp shattering and from
possible ultraviolet radiation.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR11 GU4 55109 5,7,32, 20MR11/SP10(FTB) 12 10 Spot C, AX 4000 5500 10 11/2
37
55107 5,7,32, 20MR11/FL35(FTD) 12 10 Flood C, AX 4000 700 35 11/2
37
35 MR11 GU4 55113 5,10,32, 35MR11/SP10(FTE) 12 10 Spot C, AX 4000 3800 10 11/2
37
55111 5,10,32, 35MR11/FL35(FTH) 12 10 Flood C, AX 4000 1500 35 11/2
37
MR16, MR11
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
54
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
TRU-AIM®
TRU-AIM®COVERED MR
TRU-AIM TITAN®Covered MR16
UV Filter capsule with axial filament in constant color, hard coated dichroic reflector.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
35 MR16 GU5.3 58549 5,8,10, 35MR16/T/NFL25/C 12 10 Narrow C, AX 4000 1650 25 13/4
27,38 Flood
TRU-AIM BRILLIANT®Covered MR16
UV Filter capsule with axial filament in constant color, aluminized reflector.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR16 GU5.3 58570 5,7,8, 20MR16/B/FL35/C 12 10 Flood C, AX 4000 600 35 13/4
27,36
58569 5,7,8, 20MR16/B/NSP8/C 12 10 Narrow Spot C, AX 4000 4400 8 13/4
27,36
35 MR16 GU5.3 58539 5,8,10, 35MR16/B/NSP8/C 12 10 Narrow Spot C, AX 4000 8700 8 13/4
27,36
50 MR16 GU5.3 58574 5,8,10, 50MR16/B/NSP11/C 12 10 Narrow Spot C, AX 4000 10000 11 13/4
27,36
58575 5,8,10, 50MR16/B/FL35/C 12 10 Flood C, AX 4000 1800 35 13/4
27,36
TRU-AIM Covered MR11
UV Filter capsule with axial filament in dichroic reflector.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 MR11 GU4 55119 5,7,8, 20MR11/FL35/C(FTD) 12 10 Flood C, AX 4000 700 35 15/8
27,39
ALUMINUM REFLECTOR
AR70 ALUMINUM REFLECTOR
UV Filter capsule with axial filament in precisely engineered aluminum reflector.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
20 AR70 BA15d 59013 27,40 20AR70/SP8 12 10 Spot C, C-8 3000 7700 8 115/16
59012 27,40 20AR70/FL25 12 10 Flood C, C-8 3000 900 25 115/16
50 AR70 BA15d 59017 27,40 50AR70/SP8 12 10 Spot C, C-8 3000 12500 8 115/16
59016 27,40 50AR70/FL25 12 10 Flood C, C-8 3000 2600 25 115/16
AR111 ALUMINUM REFLECTOR
UV Filter capsule with axial filament in precisely engineered aluminum reflector.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
35 AR111 G53 55101 27,40 35AR111/SSP4/6V 66Super Spot C, C-8 3000 30000 4 23/8
55102 27,40 35AR111/SSP4 12 6 Super Spot C, C-8 3000 40000 4 23/8
55110 27,40 35AR111/SP8 12 6 Spot C, C-8 3000 14000 8 25/16
55114 27,40 35AR111/FL25 12 6 Flood C, C-8 3000 2500 25 25/16
50 AR111 G53 55105 27,40 50AR111/SSP4 12 6 Super Spot C, C-8 3000 45000 4 23/8
55104 27,40 50AR111/SP8 12 6 Spot C, C-8 3000 20000 8 21/4
55103 27,40 50AR111/FL25 12 6 Flood C, C-8 3000 4000 25 25/16
75 AR111 G53 55125 27,40 75AR111/SP8 12 6 Spot C, C-8 3000 30000 8 21/4
MR16, MR11 AR70 AR111
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 56-57
55
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
ALUMINUM REFLECTOR
UV Filter capsule with axial filament in precisely engineered aluminum reflector.
16 Avg
|
Product Symbols & Pkg Beam Class & Rated Beam MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Type Filament Life(hrs) Lumens CBCP Angle (in)
|
75 AR111 G53 55123 27,40 75AR111/FL25 12 6 Flood C, C-8 3000 5300 25 25/16
55124 27,40 75AR111/WFL45 12 6 Wide Flood C, C-8 3000 2000 45 23/16
100 AR111 G53 55129 27,40 100AR111/SP8 12 6 Spot C, C-8 3000 48000 8 21/4
55127 27,40 100AR111/FL25 12 6 Flood C, C-8 3000 8500 25 25/16
55128 27,40 100AR111/WFL45 12 6 Wide Flood C, C-8 3000 2800 45 23/16
SIRIUS MR16
15 Avg
|
Product Symbols & Pkg Lamp Class & Rated LCL MOL
|
Watts Bulb Base Number Footnotes Ordering Abbreviation Volts Qty Finish Filament Life(hrs) Lumens (in) (in)
|
50 MR16 K23D 58701 32,37 50SIRIUS/SIG64005 10 10 C 6000 220 17/8
SIG 64005
AR111 MR16
For more complete product information visit www.sylvania.com
56
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Heat resistant, hard glass.
PAR lamps are suitable for indoor and outdoor use.
Operate in any position.
Operate horizontal.
This lamp or ballast meets minimum Federal efficiency standards.
New optical system being introduced during 1998.
This ECOLOGIC®lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states.
Disposal regulations may vary; check local and state regulations.
Footnote Description
1Approximate life for 130 volt tungsten halogen lamps operated at 120 volts is within the value calculated using the recommended equations
for standard incandescent lamps, as set forth in the IES Handbook, 8th edition. Because of the uncertain nature of the halogen cycle on the
coil when operated at less than rated voltage, life of tungsten halogen lamps varies considerably and unpredictably. OSRAM SYLVANIA does
not recommend operation at other than rated voltage.
2A suitable protective shield, screening technique, or both must be used to protect people and surroundings from the possibility of a lamp
shattering and from possible ultraviolet radiation.
3Operate only in porcelain sockets.
4Infrared lamp technology
5Max. seal temperature 350˚ C
6UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector and infrared reflective coating on the
lamp capsule.
7Max pin temperature 220˚ C.
8Max temperature at lens reflector joint 240˚ C.
9UV Filter capsule with axial filament in constant color, hard coated Dichroic reflector and infrared reflective coating on the lamp capsule.
10 Max pin temperature 250˚ C.
11 State of the Art SPL Optics
12 In base up operation, heat may eventually deteriorate paper-lined or plastic sockets.
13 To avoid electric shock and/or skin burns, turn off power and allow bulb to cool before handling or attempting replacement.
15 For indoor or outdoor use where not directly exposed to weather. Exposure to weather may damage the bulb.
16 For Indoor Use only.
17 Not recommended for use in enclosed close-fitting housings.
19 Retrofit for 65BR30/FL, or 75R30/FL.
20 Because this bulb radiates considerable heat, do not use in enclosed, close fitting fixtures, or in close proximity to people, combustible mate-
rials, or substances adversely affected by heat or drying.
21 Even though this bulb may continue to light after the lens or reflector is cracked or broken, it should be replaced as soon as possible since
the pressure filled inner capsule could unexpectedly shatter, creating a risk of personal injury or property damage. In addition, the inner cap-
sule produces ultraviolet radiation that can cause injury to the eyes and skin with prolonged exposure without the blocking effect of the outer
glass bulb.
22 Use only with ceramic/porcelain sockets and in fixtures rated for this bulb type, including voltage and wattage.
23 For use only in fixtures designed specifically for dichroic Reflector Lamps.
24 Should be shielded against moisture falling on bulb.
25 For use only with heat-resisting connector and with bulb supported by bulb rim or metal shell of base.
26 UV Filter Quartz
27 Suitable for use in unshielded fixtures. Consult most recent luminaire standards for your area to determine luminaire requirements.
For more complete product information visit www.sylvania.com 57
T
U
N
G
S
T
E
N
H
A
L
O
G
E
N
SYMBOLS & FOOTNOTES FOR TUNGSTEN HALOGEN LAMPS
Footnote Description
28 For use where seal temperature does not exceed 650˚ F.
29 Starlite Low Pressure - UV Filter Quartz
30 Standard Clear - UV Filter Quartz
31 Standard Frosted - UV Filter Quartz
32 A protective shield must be used external to the lamp.
33 Standard Clear - 24V - UV Filter Quartz - Not suitable for use in open fixtures.
34 UV Filter capsule with axial filament in constant color, hard coated dichroic reflector.
35 UV Filter capsule with axial filament in aluminized reflector.
36 UV Filter capsule with axial filament in covered aluminized reflector.
37 UV Filter capsule with axial filament in dichroic reflector.
38 UV Filter capsule with axial filament in covered constant color, hard coated dichroic reflector.
39 UV Filter capsule with axial filament in covered dichroic reflector.
40 UV Filter capsule with axial filament in precisely engineered aluminum reflector.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 61
58
M
I
N
I
A
T
U
R
E
MINIATURE & AUTOMOTIVE LAMPS
17 Avg
|
Product Rated Approx Design Pkg MOL
|
Ordering Abbreviation Number Bulb Base Life (hrs) Lumens Amps Voltage (V) Qty (in) Footnotes
|
1076 36183 S8 DC Bayonet 200 402.12 1.8 13 1000 2
1130 36237 S8 DC Bayonet 200 263.89 2.63 6 1000 2
1141 36377 S8 SC Bayonet 1000 263.89 1.44 13 1000 2
1156 36521 S8 SC Bayonet 1200 402.00 2.1 13 1000 2
1156 36521 S8 SC Bayonet 1200 402.00 2.1 13 1000 2
1157 36561 S8 DC Index 1200 402.00 2.1 13 1000 2
5000 38.00 0.6 14
120MB 34503 T2.5 Mini Bayonet 10000 4.52 0.025 120 1000 1.19
120MB 34503 T2.5 Mini Bayonet 10000 4.52 0.025 120 1000 1.19
120MB 6W 34513 T2.5 Mini Bayonet 3000 18.00 0.052 120 1000 1.19
120PC 34519 T2 Bipin 7500 0.025 120 1000 1.125 1
120PSB 34557 T2 Slide Base # 5 10000 0.025 120 1000 1.11
120PSB 34557 T2 Slide Base # 5 10000 0.025 120 1000 1.11
12PSB 32983 T2 Slide Base # 5 12000 0.17 12 1000 1.11
161 34691 T3.25 W2.1x9.2D 4000 12.57 0.19 14 1000 1.054
168 34711 T3.25 W2.1x9.2D 1500 37.70 0.35 14 1000 1.054
17 33061 T1.75 W2.1x4.9D 5000 8.17 0.065 28 1000 0.8
1815 37329 T3.25 Mini Bayonet 3000 17.59 0.2 14 1000 1.19
1816 37333 T3.25 Mini Bayonet 1000 37.70 0.33 13 1000 1.19
1819 37351 T3.25 Mini Bayonet 2500 4.27 0.04 28 1000 1.19
1820 37355 T3.25 Mini Bayonet 1000 20.11 0.1 28 1000 1.19
1822 37367 T3.25 Mini Bayonet 1000 26.39 0.1 36 1000 1.19
1829 37377 T3.25 Mini Bayonet 1000 12.57 0.07 28 1000 1.19
1835 37387 T3.25 Mini Bayonet 5000 13.82 0.05 55 1000 1.19
1847 37391 T3.25 Mini Bayonet 5000 4.78 0.15 6 1000 1.19
1864 37413 T3.25 Mini Bayonet 1500 37.70 0.17 28 1000 1.19
1893 37505 T3.25 Mini Bayonet 2500 25.13 0.33 14 1000 1.19
1895 37531 G4.5 Mini Bayonet 2000 25.13 0.27 14 1000 1.06
194 34761 T3.25 W2.1x9.2D 2500 25.13 0.27 14 1000 1.054
1992 ERD 30215 T3.25 Wedge 150 804.00 2.5 14 24 1
214-2 BU 34942 T3 End Caps 1000 50.27 0.52 14 1000 1.72
2187 37747 T1.75 5/8" Wire Term 7000 3.70 0.04 28 1000 0.52
222 34967 TL3 Mini Screw 5 0.22 2 1000 0.94
2342 24:30V30MA 39307 T5 W2x4.6D 1000 0.3 24 200 0.78
24E 33181 T2 Slide Base # 3 7000 0.035 24 1000 1.69
24ESB 33189 T2 Slide Base # 5 8000 0.04 24 1000 1.11
24MB 33213 T2.5 Mini Bayonet 10000 6.28 0.07 24 1000 1.19
24PSB 33229 T2 Slide Base # 5 10000 0.072 24 1000 1.11
24X 33257 T2 Slide Base # 3 8000 0.035 24 1000 1.69
259 35027 T3.25 W2.1x9.2D 5000 8.17 0.25 6 1000 1.054
28ESB 33285 T2 Slide Base # 5 6000 0.04 28 1000 1.11
28MB 33311 T2.5 Mini Bayonet 5000 3.64 0.04 28 1000 1.19
28PSB 33327 T2 Slide Base # 5 5000 0.04 28 1000 1.11
30099 PLH 32169 T2 Socket 100 0.91 2,3,4
30110 PILOT TPLR 32161 T2 Dome Trans 1000 0.38 5
30112 PILOT TPLG 32159 T2 Dome Trans 1000 0.38 5
30120 PILOT FLR 32119 T2 Dome Fluted 1000 0.38 5
31099 PLH BAY 32173 T2.5 & T3.25 Socket 100 1.68 2,4,6
313 35133 T3.25 Mini Bayonet 500 43.92 0.17 28 1000 1.06
3157WL 59894 S8 Wedge 1200 402.12 2.1 13 1000 1.7
5000 37.69 0.59 14
327 35155 T1.75 SC Midg Flanged 4000 4.27 0.04 28 1000 0.63
328 35169 T1.75 SC Midg Flanged 1000 4.27 0.2 6 1000 0.63
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 61
59
M
I
N
I
A
T
U
R
E
MINIATURE & AUTOMOTIVE LAMPS
17 Avg
|
Product Rated Approx Design Pkg MOL
|
Ordering Abbreviation Number Bulb Base Life (hrs) Lumens Amps Voltage (V) Qty (in) Footnotes
|
330 35183 T1.75 SC Midg Flanged 1500 6.28 0.08 14 1000 0.63
334 35205 T1.75 Midget Groove 4000 4.27 0.04 28 1000 0.63
3797 24V2W 39375 T2.75 BA9S 200 16.96 0.083 24 200 0.932
382 35311 T1.75 SC Midg Flanged 15000 3.76 0.08 14 1000 0.63
385 35321 T1.75 SC Midg Flanged 10000 1.88 0.04 28 1000 0.36
387 35327 T1.75 SC Midg Flanged 7000 3.76 0.04 28 1000 0.63
388 35349 T1.75 Midget Groove 7000 3.76 0.04 28 1000 0.63
44 33459 T3.25 Mini Bayonet 3000 11.28 0.25 6 1000 0.94
4414 PAR 36 30965 PAR36 2 Screw Terminal 300 1.41 13 12 2 3/4
464 35413 T3.25 W2.1x9.2D 1500 37.70 0.17 28 1000 1.054
47 33479 T3.25 Mini Bayonet 3000 6.28 0.15 6 1000 0.94
48C 33507 T2 Slide Base # 3 7000 0.035 48 1000 1.69
48PSB 33599 T2 Slide Base # 5 10000 0.05 48 1000 1.69
502 35417 G4.5 Mini Screw 100 7.53 0.15 5 1000 1.06
516/2PK/RP 12V 35920 T5 W2.1x9.2D 300 43.98 0.312 13 12 1.49
52A TB OBS 33711 T2 Slide Base # 6 8000 0.03 24 1000 0.92
53 33719 G3.5 Mini Bayonet 1000 12.57 0.12 14 1000 0.6
55 33785 G4.5 Mini Bayonet 500 25.13 0.41 7 1000 0.84
56 33831 T1.75 W2.1x4.9D 20000 1.88 0.115 5 1000 0.8
57 33871 G4.5 Mini Bayonet 500 25.13 0.24 14 1000 0.84
60MB 33927 T2.5 Mini Bayonet 7500 9.17 0.05 60 1000 1.19
60PSB 33945 T2 Slide Base # 5 7500 0.05 60 1000 1.11
6411 12V10W 39407 T3.25 SV8.5-8 200 100.53 0.83 12 200 1.61
64111 12V5W 39431 T2.75 Mini Bayonet 240 80.42 12 200 1.29 7
6413 12V5W 39405 T3.25 SV8.5-8 200 100.53 0.4 12 200 1.61
64150 H1 12V55W 31393 T2.5 P14.5S 225 1621.06 12 100 2.43
64151 H3 12V55W 31397 T3.25 PK22S 225 1520.53 12 100 1.65 8,9
64156 H3 24V70W 31415 T3.25 PK22S 225 1834.69 24 100 1.65 8,9
6421 24V3W 39376 T3.25 SV8.5-8 1000 17.59 0.125 24 200 1.61
6424 24V5W 39411 T3.25 SV8.5-8 200 61.95 0.2 24 200 1.61
6429 24V10W 39397 T3.25 SV8.5-8 200 105.55 0.42 24 200 1.61
656 35561 T3.25 W2.1x9.2D 2500 7.79 0.06 28 1000 1.054
657 35565 T3.25 W2.1x9.2D 15000 7.79 0.08 28 1000 1.054
657 35565 T3.25 W2.1x9.2D 15000 7.79 0.08 28 1000 1.054
67 34021 G6 SC Bayonet 5000 50.27 0.69 14 1000 1.44
68 34067 G6 DC Bayonet 5000 50.27 0.59 14 1000 1.44
6PSB 32803 T2 Slide Base # 5 20000 0.14 6 1000 1.11
73 34091 T1.75 W2.1x4.9D 15000 3.77 0.08 14 1000 0.8
7327 BIPIN T1 3/4 38289 T1.75 Bipin 4000 4.27 0.04 28 1000 0.63 10
7371 38379 T1.75 Bipin 20000 1.25 0.04 12 1000 0.63
7382 38417 T1.75 Bipin 15000 3.76 0.08 14 1000 0.63
7511 P21W 24V21W 39361 S8 BAY15S 150 464.95 0.88 24 200 2.095
755 35763 T3.25 Mini Bayonet 20000 4.15 0.15 6 1000 0.94
755 35763 T3.25 Mini Bayonet 20000 4.15 0.15 6 1000 0.94
756 35771 T3.25 Mini Bayonet 15000 3.90 0.08 14 1000 1.06
757 35781 T3.25 Mini Bayonet 7500 7.79 0.08 28 1000 1.06
85 34179 T1.75 W2.1x4.9D 7000 3.77 0.04 28 1000 0.8
86 34201 T1.75 W2.1x4.9D 20000 5.03 0.2 6 1000 0.8
88 34219 S8 DC Bayonet 300 188.50 1.91 7 1000 2
89 34233 G6 SC Bayonet 750 75.40 0.58 13 1000 1.44
90 34271 G6 DC Bayonet 750 75.40 0.58 13 1000 1.44
90MB 34299 T2.5 Mini Bayonet 5000 4.67 0.03 90 1000 1.19
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 61
60
M
I
N
I
A
T
U
R
E
MINIATURE & AUTOMOTIVE LAMPS
17 Avg
|
Product Rated Approx Design Pkg MOL
|
Ordering Abbreviation Number Bulb Base Life (hrs) Lumens Amps Voltage (V) Qty (in) Footnotes
|
912 35869 T5 W2.1x9.2D 1000 150.80 1 13 500 1.49
918 35923 T5 W2.1x9.2D 500 81.62 0.54 13 500 1.49
918/2PK/RP 13V 35921 T5 W2.1x9.2D 500 81.68 0.54 13 12 1.49
93 34311 S8 SC Bayonet 700 188.50 1.04 13 1000 2
93BL2PK 13V 16810 S8 SC Bayonet 700 188.49 1.04 13 24 1.8
94 34337 S8 DC Bayonet 700 187.87 1.04 13 1000 2
NE51 B1A 32427 T3.25 Mini Bayonet 25000 0.3 105 1000 11
NE51H B2A 32429 T3.25 Mini Bayonet 25000 1.2 105 1000 11
PR12 38931 B3.5 SC Mini Flanged 15 37.69 0.5 6 1000 1 1/4
PR13 38939 B3.5 SC Mini Flanged 15 25.13 0.5 5 1000 1 1/4
PR2 38891 B3.5 SC Mini Flanged 15 10.05 0.5 2 1000 1 1/4
PR3 38901 B3.5 SC Mini Flanged 15 18.84 0.5 4 1000 1 1/4
PR4 38911 B3.5 SC Mini Flanged 10 5.02 0.27 2 1000 1 1/4
PR6 38917 B3.5 SC Mini Flanged 30 5.65 0.3 2 1000 1 1/4
SM2A PCS 30096 32249 T2 Solder Lugs 500 1.2 2,12,13
For more complete product information visit www.sylvania.com 61
M
I
N
I
A
T
U
R
E
FOOTNOTES FOR MINIATURE LAMPS
Footnote Description
1MOL = Excluding pins.
2Socket dimensions front to panel to end of terminals.
3UL File No. E31557(M) CSA File No.LR20904
4Universal lamp housings for T2.5 and T3.25 miniature bayonet based lamps.
5Universal lamp housings for T2 slide based pilot lamps.
6UL File No. E31557(M) CSA File No.LR20904
7Caution: Operates under pressure and may shutter. Use appropriate techniques to protect people and surroundings. Do not operate in close
proximity to persons, combustible materials, or substances affected by heat or drying. Do not operate over 110% rated voltage because such
operation increases pressure and lamps' tendency to shatter. Ultraviolet output may cause skin and eye irritation with prolonged exposure.
Protect bulb from abrasions and scratches. Do not insert lamps when power is on. Follow operating instructions.
8ECE Approved
9Lamp Life B3 @ 13.2 volts.
10 There are two distinctively different lamps with this part number. When ordering T-1 3/4 , #7327, please also specify category and base type.
S-11. #7327 discontinued.
11 Material : Black Phenolic
12 MIL-Std. 18236 B-MIL Std. 202B
13 Material : Plastic
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
62
OSRAM SYLVANIA: THE LEADER IN ENERGY-SAVING HID LAMPS
UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING
A brief description of the catalog format and related terminology will assist
the reader in understanding the information presented in this section.
All product families are listed in ascending wattage, followed by alphabetical
bulb designation to simplify lamp identification. Performance ratings are
based on tests conducted under controlled conditions on AC circuits with
auxiliary equipment meeting current published ANSI specifications.
Lamp performance under typical service conditions may vary from rated val-
ues. Ratings and specifications are subject to change without notice.
For more information on HID SYSTEM SOLUTIONS, refer to page 92.
ANSI CODE
This is a unique code that describes the class and the electrical characteris-
tics of the lamp and ballast as well as the fixture requirements. The code is
developed and assigned by the American National Standards Institute
(ANSI). The ANSI CODE consists of type of lamp (S = HPS, H = Mercury, M
= Metal Halide, L = LPS), followed by the ballast number, and for metal
halide lamps followed by the fixture requirement (O, E, S, F).
ARC LENGTH
Arc length is the dimension of the arc discharge measured from one elec-
trode tip to the other. This is useful for optical design of reflectors and
affects fixture efficiency.
AVERAGE LIFE (HOURS)
The average life of a lamp is based on vertical operation (unless otherwise
noted) of representative lamps operated under controlled conditions of at
least 10 hours per start (except for M1500 and Briteline lamps, which are
based on 5 hours per start). Average life is defined as the total operation
hours at which 50% (Median) of any group of lamps is still operating
(except for most High Pressures Sodium and Mercury lamps, for which 65%
of the lamps are operating at the end of life). Variations in operating condi-
tions such as bulb and base temperatures and line voltage can also affect
lamp life.
Regular operation of lamps with off times less than 15 minutes will shorten
the life of the lamp. Operating cycles shorter than 10 hours per start will
reduce lamp life as follows:
5 hours / start - Approximately 75% of rating
2.5 hours / start - Approximately 55% of rating
1.25 hours / start - Approximately 40% of rating
BASE
Most SYLVANIA HID lamp bases for general lighting are made of corrosion-
resistant brass with special lubricant to provide easy removal at end of lamp
life. See the following pages for all base illustrations.
E26 Medium - Medium (MED) bases are used on lamps in E17 bulbs and
are limited to 175W maximum.
E26 Medium Skirted - Medium skirted (Med. Skt.) bases consist of a
medium brass base with a skirt, which is mechanically connected to a
PAR38 bulb.
E39 Mogul - All (MOG) bases are embossed with letters and numbers
representing months and years. The date of installation can be recorded
by marking the letter of the current month and the number that coincides
with the last digit of the current year.
EX39 Exclusionary Mogul Base - Exclusionary Mogul bases (EXCL MOG)
are bases used on metal halide lamps having shrouded arc tubes, permit-
ting them to be used in open fixture applications. These bases are com-
patible with exclusionary or standard mogul sockets.
E39 POM - Position Oriented Mogul (POM) bases are used on lamps
designed to operate only in the horizontal position and require a special
POM socket. A pin located on the base engages in a slot within the POM
socket ensuring proper operating position of the lamp within the fixture.
Rx7s / R7s Recessed Single Contact - SYLVANIA double-ended HID
lamps with recessed single contact (RSC) bases have silver plated con-
tacts to provide maximum electrical contact.
BULB
Each bulb description consists of a letter to indicate bulb shape, followed by
numbers that indicate maximum bulb diameter in 1/8 inch increments. For
example, a BT37 bulb is a blown shape with a tubular top, 37/8 of an inch or
4 5/8 inches in diameter. Illustrations of bulb shapes are shown on the fol-
lowing pages.
Although SYLVANIA HID bulbs are made of glass designed to resist ther-
mal shock in normal applications, they must be shielded from direct contact
with liquids, such as rain, during operation to avoid bulb breakage.
COLOR RENDERING INDEX (CRI)
Color Rendering Index (CRI) is an international scale (numbering system) up
to 100 indicating the relative color rendering quality of a light source when
compared to a standard reference light source of the same chromaticity
(color temperature). The CRI expresses the degree to which colors will
appear "familiar" or "natural" under the light source selected. In general, the
higher the CRI number, the better the color rendering properties of the light
source being measured. The color rendering index of any two like sources
should only be compared if those sources have the same correlated color
temperature (CCT).
CORRELATED COLOR TEMPERATURE (CCT)
The correlated color temperature of a light source, expressed in Kelvin (K),
is a means of describing the appearance or chromaticity of the source. The
correlated color temperature of the light source contributes to the visual
appearance of the lighted space. "Warm" light sources have a low color tem-
perature (2000-3000K) and feature more light in the red/orange/yellow
range. Light with a higher color temperature (>4000K) features more blue
and is referred to as "cool."
With new installations, or group relamps, all color performance evaluations
should be made after at least 100 hours of operation (at recommended oper-
ating cycles) to allow the lamps to stabilize. Additional changes in chemistry
within the arc tube over the life of the lamp may also cause the color tem-
perature to shift as the lamp gets closer to the end of it's rated life. To mini-
mize color variation within an installation, it is recommended that HID lamps
be group relamped and run on equal operating cycles.
DIMMING HID
Most SYLVANIA HID products can be dimmed on stepped, bi-level dimming
systems provided specific guidelines are followed. Generally, most
Metalarc®metal halide lamps can be dimmed down to 50% of rated wattage
depending on the lamp type and operating position. Lumalux®high pressure
sodium lamps can also be dimmed down to 50% of rated wattage. In addi-
tion to lower light output, HID lamps may shift in overall color and exhibit a
lower color rendering index (CRI) when operated in a dimmed mode. Some
restrictions apply to both the operation of the ballast and lamp. For more
information on dimming, please reference NEMA guidelines or contact a
SYLVANIA representative.
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
63
UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING (continued)
HOW TO READ PRODUCT INFORMATION - HID
4ANSI Avg
|
Product Ballast Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation No Qty Finish Position Req Life(hrs) (initial) (mean) CRI (K) Footnotes
|
100 E17 E26 Med 67506 LU100/MED S54 20 Clear Universal O 24000+ 9500 8000 22 2100 5,34
250 BT28 E39 Mogul 64578 MS250/PS/BU-ONLY M153/E 6 Clear Base up within E 20000 23500 19000 65 4200 1,4,11,12
15˚ only
350 BT37 EX39 Excl 64769 MP350/400/PS/BU-ONLY M131/O 6 Clear Base up within O 20000 34000 24500 65 3700 4,5,12,14
400 Mogul M155/O 15˚ only 40000 29500 3500
1000 BT56 EX39 Excl 64714 MP1000/BU-ONLY M47/O 6 Clear Base up within O 12000 107000 85500 65 3500 5,8,12
Mogul 15˚ only
Please refer to the "Understanding High Intensity Discharge" section on previous pages for definitions and explanations of the category headers.
HOW TO READ ORDERING ABBREVIATIONS
FIXTURE REQUIREMENT
Developed by the American National Standard Institute (ANSI), the fixture
requirement code describes the type of fixture required for each lamp type.
See lamp warnings for additional information and proper operating instruc-
tions.
E= Lamps classified as E-type are to be used ONLY in suitably rated
enclosed luminaires.
O= Lamps classified as O-type, comply with ANSI Standard C78.387 for
containment testing and may be used in open luminaires.
S= When operated within 15 degrees of vertical, this lamp may be oper-
ated in an open luminaire provided the installation is not near people or
flammable or combustible material, otherwise it must be operated in a
suitably enclosed luminaire.
F= F-rated lamps require an enclosed fixture with a U.V filter and lens
interlock.
HOT RESTRIKE
In most instances, if an HID lamp experiences a momentary power interrup-
tion or sudden voltage drop, the lamp may extinguish. A lamp that is still
hot will not restart immediately. Because the arc tube within the lamp must
cool down before it can re-start, HID lamps have hot restrike times ranging
from 1-15 minutes depending on the product type.
KEY TO DATE OF MANUFACTURE
Consult your SYLVANIA Sales Representative or call 1-800-LIGHTBULB.
ORDERING ABBREVIATION
Ordering abbreviation provides a shorthand description of the lamp, using a
unique code which can be used when ordering a lamp if you do not know
the product number. This information can be found on the lamp etch.
PACKAGE QUANTITY
This identifies the number of lamps contained in a standard shipping carton.
PRODUCT NUMBER
Product number is a five digit number used to identify a specific SYLVANIA
lamp and should be used when ordering.
LIGHT CENTER LENGTH (LCL)
The light center length of HID lamps is a measurement from the center of
the arc tube to the bottom of the lamp base.
LUMENS
Initial lumen ratings are based on photometry under controlled conditions of
at least 10 hours per start in the prescribed position at rated lamp wattage
after 100 operating hours. HQI®, Lumalux®Super and SOX lamp ratings are
based on measurements at constant input voltage. Lamp performance under
typical service conditions may vary from rated values. Operating universal
Metalarc®lamps in off-vertical positions will result in reduced lumen output.
Mean lumens are measured on ANSI reference circuits at rated wattage
(HQI, Lumalux Super and SOX lamp ratings are based on input voltage) at
40% of average rated life except for those lamps with a "+" next to their life
rating; these lamps are measured at 50% of average rated life. All measure-
ments are based on ballast operation on systems with current crest factors
of 1.8 or less. Higher current crest factors reduce values. In actual applica-
tions on CW or CWA ballasts, mean lumens may be higher than published
ratings.
Unless otherwise noted, all photometry measurements are made on an ANSI
reference ballast at rated lamp wattage.
MAXIMUM OVERALL LENGTH (MOL)
The maximum overall length of single-ended lamps is the maximum dis-
tance from the top of the bulb to the bottom of the base. For double-ended
lamps, it is the maximum distance from end-to-end (excluding any lead-
wires).
WARM UP TIME
Most HID lamps do not have instant on capabilities. It may take several
minutes for the arc tube to stabilize before optimal light output is achieved.
WATTS
Watts shown are nominal lamp watts only.
H
I
D
MS Super Metalarc
400 Wattage
PS Pulse Start
BU ONLY Operating Position:
Base up only
MP Metalarc Pro-Tech
70 Wattage
PAR38 Bulb Type
UOperating Position
SP20 Beam Type/Angle
ECO Ecologic
LU Lumalux®
100 Wattage
DCoated
MED Medium Base
H38BP ANSI Ballast Number
100 Wattage
DX Brite White
Deluxe Coated
MS400PS/BU-ONLY MP70PAR38/U/SP20/ECO LU100/D/MED H38BP-100/DX
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
64
H
I
D
BULBS
A bulb designation consists of a let-
ter(s) to indicate the shape and a
number(s) to indicate the approxi-
mate maximum diameter in eighths of
an inch. Thus, an E17 lamp is an
Ellipsoidal shape and 17/8 of an inch
or 2 1/8 inches in diameter. Other let-
ter designations include: BT=Bulbous
Tubular; E or ED=Ellipsoidal;
ET=Ellipsoidal Tubular;
PAR=Parabolic; R=Reflector;
T=Tubular.
BASES
Lamps with screw bases have one
lead-in wire soldered or welded to the
center contact and the other soldered
or welded to the upper rim of the
base shell.
Bases with ceramic bodies have inter-
nal leads welded to either silver-plated
contacts or external lead wires.
OPERATING POSITIONS
A designated operating positions
assure maximum lamp performance.
Where it is not specified, the lamp is
suitable for operation in any position.
BT56
T
BY22d base
T
G8.5 base
T
G12 base
T
Fc2 base
T
RSC base
BT37
T
Mogul base
E25
ET23.5 PAR30 LN
PAR20
ET18
R40
PAR38
BT28
E17
RSC
RRSCRQJ
Ceramic
#8 - #10
Spade
Fc 2BY 22 d
Medium
Med.
Exclusionary
Mogul
EXCL Mog.
Mogul
Mog.
Position Oriented
Mogul
POM
Medium
Skirted
Med. Skt.
Admedium Skirted
Admed.
G12
G8.5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
65
H
I
D
HID BRAND NAME GUIDE
Note: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather
than an identical match. Individual manufacturer’s performance values should be consulted. BRAND NAME GUIDE
PHYSICAL DIMENSIONS
BRITELINE PHYSICAL SIZE (dimensions in mm)
Bulb LCL MOL
T7 (15000W) 127 256
T8 127 254
T9 127 254
HQI PHYSICAL SIZE (dimensions in mm)
Bulb LCL MOL
T6 57 114
T7 (150W) 66 132
T7.5 56 84
T9.5 81 163
T14.5 150 225
BT 175 285
MERCURY VAPOR (dimensions in inches)
Bulb LCL MOL
T16 7 11
E17 3 345 716
ET23.5 5 7 12
BT28/ED28 5 8 516
BT37/ED37 7 11 12
BT56 9 1215 38
PAR38 -- 5 716
R40 -- 7 12
METALARC METAL HALIDE (dimensions in inches)
Physical size of Metalarc, Metalarc Ceramic, Super
Metalarc & Metalarc Pro-Tech lamps
Bulb LCL MOL
T4.5 2 3 732
E17/ED17 3 1332 5 716
ED18/ET18 5 349 34
BT28/ED28 5 8 516
BT37/ED37 7 11 12
BT56 9 1215 38
T6 (39, 70W) 2 732 3 1516
T6 (150W) 2 732 4 18
T7.5 2 732 4 18
PAR20 -- 3 1732
PAR30LN -- 4 34
PAR38 -- 5 516
LUMALUX HIGH PRESSURE SODIUM (dimensions in inches)
Physical size of all Lumalux and Unalux lamps
Bulb LCL MOL
T7 5 10 116
T16 6 7811 1316
E17 3 716 5 716
ET18 5 349 34
ET23.5 5 7 34
E25 8 3415 116
BT28/ED28 5 8 3132
BT37/ED37 7 11 12
SYLVANIA GE * PHILIPS **
Metalarc®Multi-Vapor Metal Halide
Metalarc Ceramic ConstantColor CMH Master Color
Protected Multi-Vapor Protected Metal
Metalarc Pro-Tech®Halide
Super Metalarc High Output Multi-Vapor Metal Halide
Metalarc Pulse Start PulseArc Multi-Vapor Pulse Start Metal
Halide
Watt-Miser High Output
Metalarc Super Saver Multi-Vapor Metal Halide
Double-Ended
Metalarc Briteline Arcstream Metal Halide
Double-Ended
HQI®Arcstream Metal Halide
Safety Lifeguard
Metalarc Safeline®Saf-T-Gard Multi-Vapor Metal Halide
*Trademark or registered trademark of General Electric Company.
SYLVANIA GE * PHILIPS **
Safety Lifeguard
Mercury Safeline Saf-T-Gard Mercury Mercury Vapor
Lumalux®Lucalox Ceramalux HPS
Lumalux / ECO®Ecolux Ceramalux ALTO
Ceramalux ALTO
Lumalux Plus®/ ECO Ecolux NC Plus
Lumalux Mercury
Free / ECO -------- --------
Instant Restrike
Lumalux Standby Lucalox Standby XL Ceramalux
Ceramalux
Unalux®E-Z Lux RetroLux
SOX Low Pressure SOX Low Pressure SOX Low Pressure
Sodium Sodium Sodium
**Trademark or registered trademark of Philips.
MOL
1 2 3 4 5 6 7 8 9 10
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
66
H
I
D
HID LAMP COLORS CORRELATED COLOR TEMPERATURE AND COLOR RENDERING INDEX
Please refer to the “Understanding High Intensity Discharge” section for additional information.
LAMP TYPE COLOR TEMPERATURE CRI
MERCURY Brite White Deluxe (coated) 4000K 45
Clear 5900K 20
METAL HALIDE Metalarc®, Metalarc Ceramic, Super Metalarc, & HQI®Lamps
See individual product listing for color temperature and CRI data
HIGH PRESSURE SODIUM Lumalux®(clear) 1900K-2200K 20-22
Lumalux (coated) 1900K-2100K 20-22
Unalux®(clear) 1800K-2100K 20
LOW PRESSURE SODIUM SOX (clear) 1800K -45-0
The following item was accepted into the 2003 IESNA Progress Report which recognizes innovative products
introduced to the industry during that year.
150-watt METALARCPOWERBALL®CERAMIC
For weight and measure information, please visit www. sylvania.com
For more information about HID lamp warranties, please visit the warranty section of this catalog.
LAMP WARNINGS:
HID Metal Halide and Mercury lamps are marked with a “T” or “R” on their packaging. These letters provide safety information
about the lamp. Below is the text used by the FDA to describe each of the letters.
T: WARNING: This lamp should self-extinguish within 15 minutes after the outer envelope is broken or punctured. If such damage occurs,
TURN OFF AND REMOVE LAMP to avoid possible injury from hazardous shortwave ultraviolet radiation.
R: WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the
lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety
precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.
Lamp Disposal Labeling
The following information appears on the packages of high intensity discharge lamps that contain mercury. For more information on
lamp disposal labeling, see the inside back cover of this catalog.
Lamp Contains Mercury
Hg Manage in accordance with disposal laws
See www.lamprecycle.orgor 1-866-666-6850
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
67
GUIDE TO METAL HALIDE LAMPS
OSRAM SYLVANIA currently offers ten families of Metal Halide lamps:
Standard METALARC®, COMPACT METALARC, SUPER METALARC,
METALARC PRO-TECH®, METALARC POWERBALL®CERAMIC, METALARC
PULSE START, METALARC SUPER SAVER, METALARC BRITELINE,
METALARC SAFELINE®, and HQI®. These lamps are designed for general
lighting applications such as commercial, industrial lighting and outdoor
floodlighting where good color and high efficiency are desired.
STANDARD METALARC(M) — Offered in a range of wattages (from 175-
1500 watts), standard Metalarc metal halide lamps allow for design flexibili-
ty with multiple light source solutions to choose from. Metalarc lamps have
significantly higher efficacy than mercury vapor or incandescent products
and considerably better CRI than mercury vapor and high pressure sodium
lamps.
COMPACT METALARC(M) — These lamps have reduced outer jacket sizes
compared to standard metal halide lamps for use in smaller fixtures. The
reduced bulb diameter allows fixture manufacturers to design more versa-
tile, less expensive and highly efficient luminaries.
SUPER METALARC(MS) — Super Metalarc lamps are position dedicated,
which means that they are specifically designed to be run in particular oper-
ating positions. Because of this feature, these lamps exhibit improved performance over standard, universal operating metal halide lamps of
similar wattage. Product features include long life, higher maintained lumens and increased efficacy.
METALARC PRO-TECH(MP) — These are specially designed lamps that incorporate a protective shroud to contain an arc tube rupture.
Metalarc Pro-Tech lamps can be used in open or enclosed fixtures. Dedicated bases are available on both low and high wattage lamp types.
METALARC POWERBALL CERAMIC(MC or MCP) — These lamps meet today’s color critical needs by combining conventional metal halide
pulse start characteristics with improved lamp-to-lamp color consistency and high CRI (>85). Most OSRAM SYLVANIA POWERBALL lamps
use a patented rounded arc tube shape, which allows for a more uniform temperature and improved color consistency. Lamp types include
clear and coated single-ended high and low wattage lamps, along with double ended and PAR configurations.
METALARC PULSE START(M/PS) — Metalarc Pulse Start lamps utilize metal halide performance with proven ignitor technology for longer life,
improved lumen maintenance and reduced color shift over lamp life compared to standard metal halide products. Lamp configurations include
low and high wattage types, both clear and coated. Metalarc Pro-Tech designs are also available for open fixture applications.
METALARC SUPERSAVER(M/SS)— Constructed with an enhanced arc tube for peak performance, Metalarc Super Saver lamps are designed
as energy-saving, replacement metal halide lamps. The 360W Super Saver lamp is a direct retrofit for existing 400W products and the 150W
Super Saver replaces 175 W lamps -- no ballast change is required.
METALARC BRITELINE(M) — These double-ended lamps are designed for compact fixtures, which provide excellent optical control and high
efficiency. These higher wattage lamps are particularly well suited for sports lighting and outdoor floodlighting applications.
METALARC SAFELINE(MT) — Metalarc Safeline lamps are designed to self-extinguish when the outer bulb is broken reducing exposure to
possible ultraviolet radiation. These lamps are recommeded for use in sports facilities and other places of public assembly where the lamps
may be subject to breakage by external objects.
HQI — With their compact size and very short arc length, HQI metal halide lamps allow luminaire manufacturers to design highly efficient fix-
tures using proven quartz arc tube technology. The high color rendering, white light, compact size, long life and high efficacy make these
lamps ideal for color critical applications.
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
68
Enclosed fixture rated METALARC®, E-Type Lamp
R
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2192°F, 1200°C for a ceramic arc tube
and 2012°F, 1100°C for quartz). If you are uncertain, contact your fixture manufacturer.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE
RUPTURE ARE AVAILABLE.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. All horizontal lamps with position oriented mogul (POM) bases (with locating pin) require a POM socket. Do not remove pin from base.
3. All pulse start lamps require a socket rated to withstand a 4000 volt pulse.
4. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI Luminaire Code E
ENCLOSED FIXTURE
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
69
Enclosed fixture rated METALARC®E-Type (Ceramic & Quartz, G12, G8.5 & DE, UV-Stop Outer-jacket) Lamp
R
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal ceramic or quartz arc-tube. Metal Halide arc-tubes operate at high
pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-
tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2192°F, 1200°C for a ceramic arc-tube
and 2012°F, 1100°C for quartz). If you are uncertain, contact your fixture manufacturer.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Ensure that lamp is securely seated in the socket.
2. If lamp is touched with bare hands, clean fingerprints off with alcohol and wipe dry with clean, lint-free cloth.
3. All sockets must be rated to withstand the maximum pulse voltage output of the ballast.
4. Never install the lamp into an ordinary household socket or a fixture intended for tungsten halogen lamps.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI Luminaire Code E
ENCLOSED FIXTURE
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
70
Open Fixture Rated, METALARC PRO-TECH®, O-Type Lamp
R
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate with compatible ballast and fixture. (See catalog for specific information.)
2. Only operate lamp in designated operating positions. (See catalog for illustration.)
3. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
4. Never expose operating lamp to moisture (such as rain, sleet or snow).
5. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
6. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.
7. Replace lamp at or before the end of rated life. (See catalog for rated life.)
This lamp is intended for use in open fixtures since it contains a special shield which was designed to contain a ruptured arc-tube and thereby minimize the result-
ant risks of personal injury, property damage, burns and fire. In applications where an additional measure of safety is desired, an enclosed fixture may be used
with a lens/diffuser material able to contain hot lamp fragments (up to 2192°F, 1200°C for a ceramic arc tube and 2012°F, 1100°C for quartz). If you are uncertain,
contact your fixture manufacturer.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. All pulse start lamps require a socket rated to withstand a 4000 volt pulse.
3. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI Luminaire Code O
OPEN FIXTURE permissible
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
71
METALARC®, S-Type Lamp
R
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer. When operated within 15° of vertical, this lamp may be operated in an open fixture PROVIDED THE INSTALLATION IS
NOT NEAR PEOPLE OR FLAMMABLE OR COMBUSTIBLE MATERIAL.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE
RUPTURE ARE AVAILABLE.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is
broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are
used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms
to the following federal regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. All horizontal lamps with position oriented mogul (POM) bases (with locating pin) require a POM socket. Do not remove pin from base.
3. All pulse start lamps require a socket rated to withstand a 4000 volt pulse.
4. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI Luminaire Code S
ENCLOSED FIXTURE/Open if meets
requirement of Paragraph I.1 below
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
72
METALARC®SAFELINE®, S-Type Lamp
T
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at
very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can
burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer. When operated within 15° of vertical, this lamp may be operated in an open fixture PROVIDED THE INSTALLATION IS
NOT NEAR PEOPLE OR FLAMMABLE OR COMBUSTIBLE MATERIAL.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in designated operating positions. (See catalog for illustration.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE
RUPTURE ARE AVAILABLE.
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III ULTRAVIOLET RADIATION EXPOSURE: This lamp should self-extinguish within 15 minutes after the outer envelope is broken or punctured. If such damage
occurs, TURN OFF AND REMOVE LAMP to avoid possible injury from hazardous shortwave ultraviolet radiation. This product conforms to the following federal
regulations: U.S.A.: 21 CFR 1040.30 and CANADA: SOR/80-381
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI Luminaire Code S
ENCLOSED FIXTURE/Open if meets
requirement of Paragraph I.1 below
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
73
METALARC®BRITELINE, F-Type Lamp
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures. The arc-tube can
unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication resulting in the discharge of glass fragments and
extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer.
2. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
3. Only operate lamp in horizontal position. (See catalog for allowable deviation from horizontal.)
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if bulb is scratched, cracked or damaged in any way.
7. Keep all metals at least 3 inches from the body of the arc tube to avoid glass decomposition.
8. Replace lamp at or before the end of rated life. (See catalog for rated life.)
II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 3 PER ANSI-IESNA Rp-27.3-
96. THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INJURY FROM SHORTWAVE ULTRAVIOLET RADIATION. IT MUST BE OPERATED IN AN ENCLOSED
FIXTURE WHICH FILTERS OUT THE HARMFUL SHORTWAVE ULTRAVIOLET RADIATION. IF YOU ARE UNCERTAIN, CONTACT YOUR FIXTURE MANUFACTURER.
A power interlock device is required to automatically turn off the lamp if the fixture assembly is opened. It is strongly recommended that a power interlock device
also turn off power to the lamp if the fixture lens is broken. If the fixture lens breaks and the lamp remains on, turn off power immediately and repair before re-
energizing.
This lamp is to be used ONLY in a fixture specifically designed for use with this lamp and recommended for its use by the equipment manufacturer.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing.
IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled,
fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and
premature lamp failure. Dry lamp carefully with clean cotton cloth.
1. Install lamp without undue pressure.
2. Ensure that lamp electrical connections are secure and nothing is touching bulb.
3. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp.
4. Fixture wiring must have a temperature rating of 250° C and a minimum voltage rating of 600 V RMS for all lamps except the 1500T7 lamp which must have
a voltage rating of 1500V RMS.
5. For maximum performance, all double-ended lamps must be operated with the arc-tube tip up.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI Luminaire Code F
ENCLOSED FIXTURE with UV
filter and lens interlock required
H
I
D
T (G8.5 base) T (G12 base) T (RSC base) E17 BT28 PAR20 PAR30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
74
H
I
D
METALARC®METAL HALIDE
METALARC POWERBALL®CERAMIC
High CRI, Pulse Start, UV Stop – Enclosed Fixtures Only
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
39 T4.5 G8.5 64791 MC39TC/U/G8.5/830 M130/E 12 Clear Universal E 9000 3300 2640 82 3000 1,2,3,
4,5
T6 G12 64363 MC39T6/U/G12/830 M130/E 12 Clear Universal E 9000 3400 2720 82 3000 1,2,3,
4,5
70 T4.5 G8.5 64792 MC70TC/U/G8.5/830 M139/E 12 Clear Universal E 9000 6600 5280 83 3000 1,2,3,
4,5,6
T6 G12 64361 MC70T6/U/G12/830 M139/E 12 Clear Universal E 9000 6700 5360 87 3000 1,2,3,
4,5,6
64338 MC70T6/U/G12/940 M139/E 12 Clear Universal E 9000 5800 4640 90 4200 1,2,3,
4,5,6
R7S RSC 64793 MC70T6/DE/830 M139/E 12 Clear HOR ± 45° E 12000 6600 5120 88 3000 1,2,4,
5,6,7
150 T6 G12 64337 MC150T6/U/G12/940 M102/E 12 Clear Universal E 9000 12700 10160 90 4200 1,2,3,
5,8
T7.5 G12 64359 MC150T7.5/G12/U/830 M102/E 12 Clear Universal E 9000 14500 11600 89 3000 1,2,3,
5,8
R7S RSC 64794 MC150T7.5/DE/830 M102/E 12 Clear HOR ± 45° E 12000 14800 11840 91 3000 1,2,5,
9
METALARC POWERBALL CERAMIC
High CRI, Pulse Start, UV Stop – Open or Enclosed Fixtures
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
70 E17 E26 Med 64739 MCP70/U/MED/830 M139/O 12 Clear Universal O 12000 5900 4700 88 3000 1,5,6,
10,11
64740 MCP70/C/U/MED/830 M139/O 12 Coated Universal O 12000 5500 4400 88 3000 1,5,6,
10,11
100 E17 E26 Med 64743 MCP100/U/MED/830 M90/O 12 Clear Universal O 12000 9000 7200 85 3000 1,5,10,
11,12
64744 MCP100/C/U/MED/830 M90/O 12 Coated Universal O 12000 8500 6900 85 3000 1,5,10,
11,12
150 E17 E26 Med 64741 MCP150/U/MED/830 M102/O 12 Clear Universal O 12000 13000 11000 89 3000 1,5,8,
10,11
64742 MCP150/C/U/MED/830 M102/O 12 Coated Universal O 12000 12000 10000 89 3000 1,5,8,
10,11
250 BT28 EX39 Excl 64786 MCP250/PS/BU-ONLY/940 M153/O 6 Clear BU ± 15° O 15000 24000 19200 94 4200 1,10,11,
Mogul 13
64821 MCP250/C/PS/BU-ONLY/940 M153/O 6 Coated BU ± 15° O 15000 22500 18000 94 4000 1,10,11,
13
METALARC POWERBALL CERAMIC - PAR LAMPS
High CRI, Pulse Start, UV Stop, PAR Type – Open or Enclosed Fixtures
5Avg Approx
|
Product ANSI Pkg Beam Beam Operating Fix Rated Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Type Angle Position Req Life(hrs)MBCP (initial) CRI (K) Footnotes
|
39 PAR20 E26 Med 64747 MCP39PAR20/U/830/SP M130/O 12 SP 10 Universal O 9000 22000 2000 85 2900 1,3,4,
5,10,11
64748 MCP39PAR20/U/830/FL M130/O 12 FL 30 Universal O 9000 5000 2000 85 2900 1,3,4,
5,10,11
PAR30LN E26 Med 64755 MCP39PAR30LN/U/830/SP M130/O 6 SP 10 Universal O 9000 39600 2300 85 2900 1,3,4,
5,10,11
PAR30 PAR38 E17
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
75
H
I
D
METALARC®METAL HALIDE
METALARC POWERBALL®CERAMIC - PAR LAMPS
High CRI, Pulse Start, UV Stop, PAR Type – Open or Enclosed Fixtures
5Avg Approx
|
Product ANSI Pkg Beam Beam Operating Fix Rated Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Type Angle Position Req Life(hrs)MBCP (initial) CRI (K) Footnotes
|
39 PAR30LN E26 Med 64756 MCP39PAR30LN/U/830/FL M130/O 6 FL 30 Universal O 9000 7400 2300 85 2900 1,3,4,
5,10,11
70 PAR30LN E26 Med 64745 MCP70PAR30LN/U/830/SP M139/O 6 SP 12 Universal O 9000 46000 4400 85 2900 1,4,5,
6,10,11
64746 MCP70PAR30LN/U/830/FL M139/O 6 FL 30 Universal O 9000 16000 4400 85 2900 1,4,5,
6,10,11,14,
PAR38 E26 Med Skt 64749 MCP70PAR38/U/SP/830/ECO M139/O 6 SP 15 Universal O 10000 40000 4300 85 3000 1,5,
6,10,11,15
64750 MCP70PAR38/U/FL/830/ECO M139/O 6 FL 25 Universal O 10000 16000 4300 85 3000 1,5,
6,10,11,15
64751 MCP70PAR38/U/VWFL/830/ECO M139/O 6 VWFL 65 Universal O 10000 3500 4300 85 3000 1,5,
6,10,11,15
100 PAR38 E26 Med Skt 64752 MCP100PAR38/U/SP/830/ECO M90/O 6 SP 15 Universal O 12000 58000 6500 85 3000 1,5,
10,11,12,15,
16
64753 MCP100PAR38/U/FL/830/ECO M90/O 6 FL 25 Universal O 12000 25000 6500 85 3000 1,5,
10,11,12,15,
16
64754 MCP100PAR38/U/VWFL/830/ECOM90/O 6 VWFL 60 Universal O 12000 6000 6500 85 3000 1,5,
10,11,12,15,
16
150 PAR38 E26 Med Skt 64841 MCP150/PAR38/U/830/SP M102/O 6 SP 15 Universal O 9000 50000 9100 85 3000 1,8,
10,11,15,16
64842 MCP150/PAR38/U/830/FL M102/O 6 FL 25 Universal O 9000 28000 9100 85 3000 1,8,
10,11,15,16
64843 MCP150/PAR38/U/830/VWFL M102/O 6 VWFL 65 Universal O 9000 6500 9100 85 3000 1,8,
10,11,15,16
METALARC PULSE START & METALARC PRO-TECH®
High Output, Reduced Color Shift, Low Wattage, Quartz – Open or Enclosed Fixtures
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
50 E17 E26 Med 64587 MP50/U/MED M110/O 20 Clear Universal O 20000V 3450 1900 70 3000 10,11
10000H
64588 MP50/C/U/MED M110/O 20 Coated Universal O 20000V 3200 1750 70 2900 10,11
10000H
70 E17 E26 Med 64547 MP70/U/MED M98/O 20 Clear Universal O 15000V 5200 3400 75 3000 10,11
10000H
64546 MP70/C/U/MED M98/O 20 Coated Universal O 15000V 4700 3100 75 2900 10,11
10000H
64625 MPD70/U/MED/840 M98/O 20 Clear Universal O 7500V 5500 4000 80 4200 10,11
6000H
64621 MPD70/C/U/MED/840 M98/O 20 Coated Universal O 7500V 5100 3800 82 4000 10,11
6000H
100 E17 E26 Med 64417 MP100/U/MED M90/O 20 Clear Universal O 15000V 8500 5525 75 3000 10,11
10000H
64418 MP100/C/U/MED M90/O 20 Coated Universal O 15000V 7900 5800 75 2900 10,11
10000H
64426 MPD100/U/MED/840 M90/O 20 Clear Universal O 7500V 8400 5800 82 4200 10,11
6000H
64433 MPD100/C/U/MED/840 M90/O 20 Coated Universal O 7500V 7700 5500 82 4000 10,11
6000H
E17 PAR38 BT28
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
76
H
I
D
METALARC®METAL HALIDE
METALARC PULSE START & METALARC PRO-TECH®
High Output, Reduced Color Shift, Low Wattage, Quartz – Open or Enclosed Fixtures
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
150 E17 E26 Med 64402 MP150/U/MED M102/O 20 Clear Universal O 15000V 12900 10000 75 3000 10,11
10000H
64406 MP150/C/U/MED M102/O 20 Coated Universal O 15000V 11600 9000 75 2900 10,11
10000H
64403 MPD150/U/MED/840 M102/O 20 Clear Universal O 7500V 12500 11000 88 4200 10,11
6000H
64425 MPD150/C/U/MED/840 M102/O 20 Coated Universal O 7500V 11500 9500 88 4000 10,11
6000H
METALARC PULSE START
High Output, Reduced Color Shift, Low Wattage, Quartz, PAR Type – Open or Enclosed Fixtures
5Avg Approx
|
Product ANSI Pkg Beam Beam Operating Fix Rated Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Type Angle Position Req Life(hrs)MBCP (initial) CRI (K) Footnotes
|
70 PAR38 E26 Med Skt 64590 MP70PAR38/U/SP20/ECO M98/O 6 SP 20 Universal O 8500 18000 3400 75 3200 10,11,15,
16
64592 MP70PAR38/U/FL35/ECO M98/O 6 FL 35 Universal O 8500 10000 3400 75 3200 10,11,15,
16
64594 MP70PAR38/U/VWFL65/ECO M98/O 6 VWFL 65 Universal O 8500 3000 3400 75 3200 10,11,15,
16
100 PAR38 E26 Med Skt 64580 MP100PAR38/U/SP20/ECO M90/O 6 SP 20 Universal O 8500 26000 5800 75 3000 10,11,15,
16
64582 MP100PAR38/U/FL35/ECO M90/O 6 FL 35 Universal O 8500 12000 5800 75 3000 10,11,15,
16
64584 MP100PAR38/U/VWFL65/ECO M90/O 6 VWFL 65 Universal O 8500 4500 5800 75 3000 10,11,15,
16
150 PAR38 E26 Med Skt 64593 MP150PAR38/U/SP20/ECO M102/O 6 SP 20 Universal O 8500 34000 8800 75 3200 10,11,15,
16
64597 MP150PAR38/U/FL35/ECO M102/O 6 FL 35 Universal O 8500 17000 8800 75 3200 10,11,15,
16
64599 MP150PAR38/U/VWFL65/ECO M102/O 6 VWFL 65 Universal O 8500 7500 8800 75 3200 10,11,15,
16
METALARC PULSE START
High Output, Reduced Color Shift, High Wattage
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
175 ED17 E26 Med 64171 MS175/PS/BU-ONLY/MED M152/E 12 Clear BU ± 15° E 15000 17500 12800 65 4000 2,10,13,27
64170 MS175/C/PS/BU-ONLY/MED M152/E 12 Coated BU ± 15° E 15000 16600 12500 70 3700 2,10,13,27
ED28 E39 Mogul 64815 MS175/PS/BU-ONLY M152/E 12 Clear BU ± 15° E 15000 17500 12800 65 4200 2,10,13
64816 MS175/C/PS/BU-ONLY M152/E 12 Coated BU ± 15° E 15000 16000 12500 70 4000 2,10,13
200 ET23.5 E39 Mogul 64837 MS200/PS/BU-ONLY/ET23.5 M136/E 6 Clear BU ± 15° E 15000 19000 13300 65 4200 2,10,13
BT28 E39 Mogul 64838 MS200/PS/BU-ONLY/BT28 M136/E 6 Clear BU ± 15° E 15000 19000 13500 65 4000 2,10,13
64839 MS200/C/PS/BU-ONLY/BT28 M136/E 6 Coated BU ± 15° E 15000 18000 12800 65 3800 2,10,13
250 BT28 EX39 Excl 64789 MP250/PS/BU-ONLY M153/O 6 Clear BU ± 15° O 15000 22500 17000 65 4000 10,11,13
Mogul
64790 MP250/C/PS/BU-ONLY M153/O 6 Coated BU ± 15° O 15000 21000 16000 70 4000 10,11,13
E39 Mogul 64578 MS250/PS/BU-ONLY M153/E 6 Clear BU ± 15° E 20000 23500 19000 65 4200 2,10,13
BT28 BT37 E17
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
77
H
I
D
METALARC®METAL HALIDE
METALARC PULSE START
High Output, Reduced Color Shift, High Wattage
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
250 BT28 E39 Mogul 64617 MS250/C/PS/BU-ONLY M153/E 6 Coated BU ± 15° E 20000 21500 17000 70 3600 2,10,13
320 BT28 E39 Mogul 64507 MS320/PS/BU-HOR M154/E 6 Clear BU-HOR E 20000V 32000V 21000V 65 4300 2,10,13,17
15000H 30000H 19700H
64646 MS320/C/PS/BU-HOR M154/E 6 Coated BU-HOR E 20000V 30000V 19700V 70 3900 2,10,13,17
15000H 28000H 18400H
320 BT28 EX39 Excl 64391 MP320/350/PS/BU-ONLY/BT28 M154/O 6 Clear BU ± 15° O 20000 28600 21000V 65 3800 10,11,13,17
Mogul M131/O 20000 33500 24000H 65 3600
64349 MP320/350/C/PS/BU-ONLY/BT28 M154/O 6 Coated BU ± 15° O 20000 27700 19000V 70 3600 10,11,13,17
M131/O 20000 32000 22000H 70 3600
350 BT37 EX39 Excl 64769 MP350/400/PS/BU-ONLY M131/O 6 Clear BU ± 15° O 20000 33000 24500V 65 3700 10,11,13,18
Mogul M155/O 20000 40000 29500H 65 3500
64770 MP350/400/C/PS/BU-ONLY M131/O 6 Coated BU ± 15° O 20000 32000 23000V 70 3500 10,11,13,18
M155/O 20000 39000 28000H 70 3300
400 BT37 E39 Mogul 64525 MS400/PS/BU-ONLY M155/S 6 Clear BU ± 15° S 20000 42000 31000 65 4000 10,13,18,19,
20
64527 MS400/C/PS/BU-ONLY M155/S 6 Coated BU ± 15° S 20000 42000 29000 70 3600 10,13,18,19,
20
750 BT37 E39 Mogul 64787 MS750/PS/BU-HOR/BT37 M149/E 6 Clear BU-HOR E 16000V 80000V 60000V 65 4000 2,10,21
12000H 68000H 51000H
64822 MS750/C/PS/BU-HOR/BT37 M149/E 6 Coated BU-HOR E 16000V 75000V 56000V 70 3700 2,10,21
12000H 65000H 48500H
1000 BT37 E39 Mogul 64351 M1000/PS/U/BT37 M141/E 6 Clear Universal E 15000V 110000V96000V 65 3800 2,10
9000H 107800H86300H
METALARC SUPERSAVER®
Energy Saving, Metal Halide Retrofit
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
150 BT28 E39 Mogul 64719 M150/SS/U/BT-28 M107/E 6 Clear Universal E 10000V 13000V 7500V 65 4000 2,22,23
7500H 12000H 8500H
360 BT37 E39 Mogul 64655 MS360/SS/BU-HOR M59/S 6 Clear BU-HOR S 20000V 36000V 23500V 65 3600 20,23,24
15000H 30000H 19000H
64656 MS360/C/SS/BU-HOR M59/S 6 Coated BU-HOR S 20000V 36000V 22500V 70 3600 20,23,24
15000H 30000H 19000H
EX39 Excl 64737 MSP360/SS/BU-ONLY M59/O 6 Clear BU ± 15° O 20000 36000 23500 65 4000 11,23,24
Mogul
64738 MSP360/C/SS/BU-ONLY M59/O 6 Coated BU ± 15° O 20000 34500 22500 70 3600 11,23,24
ED28 E39 Mogul 64828 MS360/SS/BU-ONLY/ED28 M59/E 12 Clear BU ± 15° E 20000 36000 23400 65 4000 2,23,24
64829 MS360/C/SS/BU-ONLY/ED28 M59/E 12 Coated BU ± 15° E 20000 34200 22000 70 3700 2,23,24
METALARC SUPER
High Output, Position Dedicated
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
175 BT28 E39 POM Mogul 64439 MS175/HOR M57/E 6 Clear HOR ± 15° E 7500 15000 10000 65 4200 2,25
64440 MS175/C/HOR M57/E 6 Coated HOR ± 15° E 7500 14500 9700 70 4000 2,25
250 BT28 E39 POM Mogul 64448 MS250/HOR M58/E 6 Clear HOR ± 15° E 10000 23000 15000 65 4200 2,25
BT28 BT37 BT56 E17 ET18
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
78
H
I
D
METALARC®METAL HALIDE
METALARC SUPER
High Output, Position Dedicated
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
250 BT28 E39 POM Mogul 64449 MS250/C/HOR M58/E 6 Coated HOR ± 15° E 10000 22000 14000 70 3800 2,25
64496 MS250/3K/HOR M58/E 6 Coated HOR ± 15° E 10000 17200 12500 70 3200 2,25
400 BT28 E39 POM Mogul 64443 MS400/HOR/BT28 M59/E 6 Clear HOR ± 15° E 20000 40000 26000 65 4200 2,25
64444 MS400/C/HOR/BT28 M59/E 6 Coated HOR ± 15° E 20000 36500 24000 70 3800 2,25
BT37 E39 POM Mogul 64445 MS400/HOR M59/E 6 Clear HOR ± 15° E 20000 40000 26000 65 4200 2,25
64446 MS400/C/HOR M59/E 6 Coated HOR ± 15° E 20000 38000 24000 70 3800 2,25
64498 MS400/3K/HOR M59/E 6 Coated HOR ± 15° E 20000 33500 23300 70 3200 2,25
BT28 E39 Mogul 64441 MS400/BU-ONLY/BT28 M59/E 6 Clear BU ± 15° E 20000 42000 26000 65 3800 2
BT37 E39 Mogul 64450 MS400/BU-ONLY M59/S 6 Clear BU ± 15° S 20000 42000 26000 65 4000 20,26
64452 MS400/C/BU-ONLY M59/S 6 Coated BU ± 15° S 20000 42000 24700 70 3600 20,26
64454 MS400/3K/BU-ONLY M59/S 6 Coated BU ± 15° S 20000 35000 22000 70 3200 20
64451 MS400/BD-ONLY M59/S 6 Clear BD ± 15° S 20000 42000 26000 65 4000 20
1000 BT56 E39 Mogul 64435 MS1000/BU-ONLY M47/S 6 Clear BU ± 15° S 18000 115000 92000 65 4000 20
64460 MS1000/C/BU-ONLY M47/S 6 Coated BU ± 15° S 18000 110000 88000 70 3400 20
64436 MS1000/BD-ONLY M47/S 6 Clear BD ± 15° S 18000 115000 92000 65 4000 20
STANDARD METALARC & METALARC PRO-TECH®(OPEN FIXTURE RATED)
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
175 E17 E26 Med 64479 M175/U/MED M57/E 20 Clear Universal E 10000V 14400V 9300 65 4000 2
7500H 12800H
64480 M175/C/U/MED M57/E 20 Coated Universal E 10000V 13000V 8400 70 3600 2
7500H 11080H
64733 MP175/BU-ONLY/MED M57/O 20 Clear BU ± 15° O 10000 14400 10800 65 3600 11
BT28 E39 Mogul 64471 M175/U M57/E 6 Clear Universal E 10000V 14400V 9300 65 4200 2
7500H 12800H
64472 M175/C/U M57/E 6 Coated Universal E 10000V 14000V 8400 70 3800 2
7500H 12000H
64473 M175/3K/BU-ONLY M57/E 6 Coated BU ± 15° E 10000 11800 7600 70 3200 2
EX39 Excl 64773 MP175/BU-ONLY M57/O 6 Clear BU ± 15° O 10000 14400 10200 65 4000 11
Mogul
64774 MP175/C/BU-ONLY M57/O 6 Coated BU ± 15° O 10000 12800 7800 70 3800 11
250 ET18 E39 Mogul 64474 M250/U/ET18 M58/E 10 Clear Universal E 10000 22000V 17500V 65 4000 2
20000H 13500H
BT28 E39 Mogul 64457 M250/U M58/E 6 Clear Universal E 10000 22000V 17000V 65 4200 2
20000H 14100H
64458 M250/C/U M58/E 6 Coated Universal E 10000 21500V 17000V 70 3800 2
19500H 14000H
64475 M250/3K/BU-ONLY M58/E 6 Coated BU ± 15° E 10000 17500 13000 70 3200 2
EX39 Excl 64404 MP250/BU-ONLY M58/O 6 Clear BU ± 15° O 10000 23000 17000 65 4000 11
Mogul
64405 MP250/C/BU-ONLY M58/O 6 Coated BU ± 15° O 10000 20000 14350 70 3800 11
400 ET18 E39 Mogul 64575 M400/U/ET18 M59/E 10 Clear Universal E 20000V 36000V 23400V 65 4000 2
15000H 33000H 21500H
Note: LCL = 6 1/8 in; MOL = 9 3/4 in
BT28 BT37 BT56 T (RSC base)
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
79
H
I
D
METALARC®METAL HALIDE
STANDARD METALARC & METALARC PRO-TECH®(OPEN FIXTURE RATED)
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
400 BT28 E39 Mogul 64488 M400/U/BT28 M59/E 6 Clear Universal E 20000V 36000V 23500V 65 4000 2
15000H 32000H 20500H
64489 M400/C/U/BT28 M59/E 6 Coated Universal E 20000V 36000V 22500V 70 3600 2
15000H 32000H 20500H
BT37 E39 Mogul 64490 M400/U M59/S 6 Clear Universal S 20000V 36000V 23500V 65 4000 20,26
15000H 32000H 20500H
64492 M400/C/U M59/S 6 Coated Universal S 20000V 36000V 22500V 70 3700 20,26
15000H 32000H 20500H
EX39 Excl 64705 MP400/BU-ONLY M59/O 6 Clear BU ± 15° O 20000 40000 26000 65 3600 11
Mogul
64706 MP400/C/BU-ONLY M59/O 6 Coated BU ± 15° O 20000 38500 25000 70 3400 11
64717 MP400/BD-ONLY M59/O 6 Clear BD ± 15° O 20000 40000 26000 65 3600 11
1000 BT37 E39 Mogul 64469 M1000/U/BT37 M47/E 6 Clear Universal E 15000V 110000V93500V 65 3800 2
9000H 107800H86300H
BT56 E39 Mogul 64468 M1000/U M47/S 6 Clear Universal S 18000V 110000V86000V 65 4000 20
12000H 107800H86300H
64470 M1000/C/U M47/S 6 Coated Universal S 18000V 107000V80000 70 3400 20
12000H 101600H
EX39 Excl 64714 MP1000/BU-ONLY M47/O 6 Clear BU ± 15° O 12000 107000 85500 65 3500 11
Mogul
64716 MP1000/C/BU-ONLY M47/O 6 Coated BU ± 15° O 12000 100000 80000 70 3200 11
1500 BT56 E39 Mogul 64431 M1500/BU-HOR M48/E 6 Clear BU-HOR E 3000 170000V140000V70 4000 2,28
153000H127400H
64432 M1500/BD M48/E 6 Clear BD ± 15° E 3000 167000 140000 70 4000 2
METALARC BRITELINE
Double-Ended – Enclosed Fixtures Only
6Avg Arc
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Length Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life(hrs) (initial) (mean) CRI (K) (in) Footnotes
|
1500 T7 RX7S RRSC 66619 M1500T7/DE TBD 10 Clear HOR ± 4° F 3000 150000 127500 65 4200 6.71 29,30,31,32
T8 Cer #8-10 66632 M1500T8/DE M133/F 10 Clear HOR ± 4° F 6000 150000 120000 65 4200 4.3 29,31,32
Spade
2000 T8 RX7S RRSC 66627 M2000T8/DE TBD 10 Clear HOR ± 4° F 3000 200000 170000 65 4000 7.09 29,30,31,32
T9 Cer #8-10 66631 M2000T9/DE M134/F 10 Clear HOR ± 4° F 3000 200000 170000 65 4200 4.25 29,31,32
Spade
METALARC SAFELINE®
Self-Extinguishing
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
400 BT37 E39 Mogul 64707 MT400/BU-ONLY M59/S 6 Clear BU ± 15° S 20000 36000 22000 60 4500 20,33
64709 MT400/C/BU-ONLY M59/S 6 Coated BU ± 15° S 20000 35000 20600 65 4100 20,33
T (RSC base) T (Fc2 base) T (G12 base) T (Mog base) R30/R40
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
80
H
I
D
HQI®METAL HALIDE (COMPACT, HIGH CRI, QUARTZ)
HQI DOUBLE-ENDED (ENCLOSED FIXTURES)
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
70 T6 R7S RSC 64364 HQI-DE70/WDX-E Electronic 12 Clear HOR ± 45° E 10000 6000 4900 85 3000 2,5,30,
34
64362 HQI-DE70/NDX M85/E 12 Clear HOR ± 45° E 8000 5500 3800 81 4000 2,5
64360 HQI-DE70/WDX M85/E 12 Clear HOR ± 45° E 10000 4700 4300 80 3000 2,5
150 T7 R7S RSC 64366 HQI-DE150/WDX M81/E 12 Clear HOR ± 45° E 10000 11000 9000 81 3000 2,5
64368 HQI-DE150/NDX M81/E 12 Clear HOR ± 45° E 10000 11250 9500 85 4200 2,5
250 T9.5 FC2 64374 HQI-DE250/NDX M80/E 12 Clear HOR ± 45° E 10000 20000 16000 85 4200 2,5
64378 HQI-DE250/DX M80/E 12 Clear HOR ± 45° E 10000 20000 15500 93 5000 2,5
HQI SINGLE-ENDED (ENCLOSED FIXTURES)
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
150 T7.5 G12 64342 HQI-SE 150/NDX M81/E 12 Clear Universal E 9000 12500 8900 85 4200 2,5
250 T14.5 E40 Mogul 64350 HQI-SE250/DX S50/E 12 Clear Universal E 9000 19000 16000 90 5200 2,5,35
400 BT E40 Mogul 64352 HQI-SE400/DX S51/E 12 Clear Universal E 9000 33000 24000 90 5200 2,5,35
HQI FIBER-OPTIC INTEGRATED DICHROIC REFLECTOR (ENCLOSED FIXTURES)
7Avg Approx
|
Product ANSI Pkg Lamp Operating Fix Rated Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life(hrs) (initial) CRI (K) Footnotes
|
150 R30 2 Pin 64339 HQI-R150/NDX/FO M81/E 12 Clear HOR E 9000 11000 85 4200
Connector
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
81
GUIDE TO HIGH PRESSURE SODIUM LAMPS
High Pressure Sodium lamps are one of the most efficient HID sources avail-
able today. These lamps are used for general lighting applications where high
efficiency and long life are desired while color rendering is not critical. Typical
applications include street lighting, parking lot lighting, building floodlighting
and general area lighting.
LUMALUX PLUS®/ ECO®These environmentally friendlier lamps are
designed with lead-free, welded mogul bases and they contain significantly
less Mercury than standard high pressure sodium lamps. They will not cycle
at the end of life and are rated for 30,000 hours life. All lamps operate on
existing high pressure sodium ballasts and pass the existing Federal TCLP lim-
its.*
LUMALUX®MERCURY-FREE / ECO — Lumalux Mercury-free lamps incorpo-
rate the latest technology to eliminate both mercury and lead allowing them to
pass the Federal TCLP test.* These lamps provide premium Lumalux perform-
ance and operate on existing high pressure sodium ballasts.
LUMALUX AND LUMALUX / ECO — Available in a broad range of wattages, in
both clear and coated configurations, Lumalux and Lumalux / ECO lamps are
ideal for a variety of applications. Lumalux medium based lamps are available
in wattages ranging from 35-150 watts while mogul based lamps are offered in
50-1000 watts. The mogul based Lumalux / ECO lamps operate on standard
high pressure sodium ballasts and pass the Federal TCLP test.*
LUMALUX STANDBY — These lamps are designed with two arc tubes to provide instant restrike capability in the event of a momentary
power interruption. With almost twice the life of standard high pressure sodium lamps, Lumalux Standby lamps are a great way to reduce
maintenance costs.
UNALUX®These high pressure sodium retrofit lamps are designed to operate on all Mercury reactor ballasts when increased light and
reduced energy is desired.
SOX — These energy efficient low pressure sodium lamps emit a characteristic yellow light that is ideal for certain exterior street and area
lighting.
* based on NEMA LL Series Standards
LUMALUX, LUMALUX / ECO, LUMALUX PLUS / ECO, AND LUMALUX STANDBY LAMPS
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY:
This lamp must be operated in a fixture and ballast which has an ANSI designation identical to that found on the lamp outer glass bulb, otherwise the lamp may
rupture resulting in the discharge of hot particles.
II. ELECTRICAL SHOCK AND BURN HAZARD:
Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled.
III. INSTALLATION AND OPERATING INSTRUCTIONS:
See catalog for specific operating parameters.
1. A specially designed socket which is electrically rated to withstand a 4000 volt pulse is required for all High Pressure Sodium lamps except for the 750 and
1000 watt lamps which require a socket rated to withstand a 5000 volt pulse.
2. These lamps have a vacuum jacket and may implode if broken. For added safety, wear safety glasses and gloves when installing or removing bulbs.
3. To avoid burn injury, allow lamp to cool before removing from fixture.
4. Screw lamp firmly but not forcibly into socket to avoid breakage.
5. Replace lamps at or before end of rated life. (See catalog for rated life.)
6. Never install it into an ordinary household socket.
7. This lamp may be operated in any position.
IV. PROPER CARE AND MAINTENANCE:
To reduce the possibility of a rupture and premature lamp failure:
1. Do not use with luminaires which would cause an excessive increase in arc-tube operating voltage.
2. Do not expose operating lamp to moisture.
3. Replace lamp if outer glass bulb has been scratched, cracked, or damaged in any way.
4. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
WARNING
H
I
D
HERMETIC
END SEAL
DOME MOUNT SUPPORT
ALUMINA ARC-TUBE
WEATHER RESISTANT
GLASS ENVELOPE
VACUUM
RESIDUE GAS GETTER
BRASS DATE
RECORDING BASE
STEEL
FRAME
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
82
UNALUX®
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY:
This lamp will operate safely and perform satisfactorily only when used with conventional high leakage reactance lag type auto-transformer or reactor mercury
ballasts as indicated in the table below, otherwise the lamp may rupture resulting in the discharge of hot particles.
Mercury Lamp ANSI Mercury Sodium Replacement
Wattage Ballast No. Lamp Type
175 H39 150
250 H37 215
400 H33 360
1000 H36 880
TO AVOID PREMATURE LAMP FAILURE, DO NOT USE WITH CW OR CWA BALLASTS.
II. ELECTRICAL SHOCK AND BURN HAZARD:
Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power iammediately and remove lamp after it has cooled.
III. INSTALLATION AND OPERATING INSTRUCTIONS:
See catalog for specific operating parameters.
1. These lamps have a vacuum jacket and may implode if broken. For added safety, wear safety glasses and gloves when installing or removing lamps.
2. To avoid burn injury, allow lamp to cool before removing from fixture.
3. Screw lamp firmly but not forcibly into socket to avoid breakage.
4. Replace lamp at or before the end of rated life. (See catalog for rated life.)
5. This lamp may be operated in any position.
IV. PROPER CARE AND MAINTENANCE:
To reduce the possibility of a rupture and premature lamp failure:
1. Do not use with luminaires which would cause an excessive increase in arc-tube operating voltage.
2. Do not expose operating lamp to moisture.
3. Replace lamp if outer glass bulb has been scratched, cracked or damaged in any way.
4. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
LUMALUX®Double-Ended Quartz Jacketed Lamps
I. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY: This lamp must be operated in a fixture and ballast which has an ANSI designation identical to
that found on the lamp outer glass bulb.
II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 2 PER ANSI-IESNA Rp-27.3-
96. THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INJURY FROM SHORTWAVE ULTRAVIOLET RADIATION. IT MUST BE OPERATED IN AN ENCLOSED
FIXTURE WHICH FILTERS OUT THE HARMFUL SHORTWAVE ULTRAVIOLET RADIATION. IF YOU ARE UNCERTAIN, CONTACT YOUR FIXTURE MANUFACTURER.
A power interlock device is required to automatically turn off the lamp if the fixture assembly is opened. It is strongly recommended that a power interlock device
also turn off power to the lamp if the fixture lens is broken. If the fixture lens breaks and the lamp remains on, turn off power immediately and repair before re-
energizing.
This lamp is to be used ONLY in a fixture specifically designed for use with this lamp and recommended for its use by the equipment manufacturer.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing.
IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled,
fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and
premature lamp failure. Dry lamp carefully with clean cotton cloth.
1. Install lamp without undue pressure.
2. Ensure that lamp electrical connections are secure and nothing is touching bulb.
3. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp.
4. Fixture wiring must have a temperature rating of 250° C and a minimum voltage rating of 600 V RMS.
5. Never install it into a fixture designed for use with tungsten halogen lamps.
6. Do not expose operating lamp to moisture (such as rain, sleet or snow).
7. Replace lamp if outer glass bulb has been scratched, cracked, or damaged in any way.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
ANSI LUMINAIRE Code F
ENCLOSED FIXTURE with UV
Filter and lens interlock required
WARNING
WARNING
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
83
SOX LAMPS
I. BURNS AND FIRE HAZARD:
Sox lamps contain a quantity of sodium which may heat from a reaction with moisture in the air or on the skin if a lamp is broken. Hot sodium will burn sponta-
neously when exposed to the air. Sodium lamps must be packed, shipped, and stored in the wrapping provided to reduce the risk of breakage.
II. IMPLOSION HAZARD:
Always wear safely glasses when handling lamp. Low pressure sodium lamps are made of glass and are evacuated and could therefore implode if damaged or
handled incorrectly. Replace lamp if outer glass bulb has been scratched, cracked, or damaged in any way. To reduce the possibility of a lamp cracking or break-
ing, do not expose operating lamp to rain, snow, or water.
III. ELECTRICAL SHOCK AND BURN HAZARD:
Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled.
IV. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY:
This lamp must be operated in a fixture and ballast which was specifically designed for use with this lamp.
V. INSTALLATION AND OPERATING INSTRUCTIONS:
1. When operated in other than the base up orientation, single-based "SOX" lamps of from 35 watts to 180 watts must be supported at the end opposite to the
base in such a way as to allow for thermal expansion and contraction along the lamp axis.
2. Install lamp firmly but not forcibly into socket to avoid breakage.
3. For maximum system performance, replace lamp at or before end of rated life. (See catalog for rated life.)
4. Only operate lamps in designated operating positions. (See catalog for illustration.)
VI. LAMP DISPOSAL:
To avoid the risk of personal injury or property damage from sodium reaction when disposing of spent lamps, the following procedure should be followed:
1. Before commencing, operator must be outfitted with appropriate OSHA-approved face mask, gloves and apron.
2. Place no more than 20 lamp(s) in a large, dry container. (Do not exceed one-quarter of the container height.)
3. Break lamp(s) into small pieces inside the container in a dry atmosphere and in a well ventilated area.
4. From a safe distance, carefully pour enough tap water into container to cover all materials.
5. After a few minutes, the reaction of the sodium with the large quantity of water will produce a mild sodium hydroxide solution which may be disposed of in
accordance with applicable federal, state and local regulations.
WARNING
H
I
D
ET23.5, BT28 ET18 E17
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
84
H
I
D
LUMALUX®HIGH PRESSURE SODIUM
LUMALUX PLUS/ECO
Non-Cycling, Environmentally Friendlier
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
50 ET23.5 E39 Mogul 67607 LU50/PLUS/ECO S68 20 Clear Universal O 30000 4000 3600 22 1900 10,15,36
70 ET23.5 E39 Mogul 67497 LU70/PLUS/ECO S62 20 Clear Universal O 30000 6300 5600 22 1900 10,15,36
100 ET23.5 E39 Mogul 67559 LU100/PLUS/ECO S54 20 Clear Universal O 30000 9800 8550 22 2100 10,15,36
150 ET23.5 E39 Mogul 67494 LU150/55/PLUS/ECO S55 20 Clear Universal O 30000 16000 14400 22 2100 10,15,36,
37,38
200 ET18 E39 Mogul 67495 LU200/PLUS/ECO S66 20 Clear Universal O 30000 22000 19800 22 2100 10,15,36
250 ET18 E39 Mogul 67572 LU250/PLUS/ECO S50 20 Clear Universal O 30000 29000 26100 22 2100 10,15,36
310 ET18 E39 Mogul 67660 LU310/PLUS/ECO S67 20 Clear Universal O 30000 37000 33300 22 2100 10,15,36
400 ET18 E39 Mogul 67312 LU400/PLUS/ECO S51 20 Clear Universal O 30000 50000 45000 22 2100 10,15,36
LUMALUX HGF/ECO®
Mercury Free, Environmentally Friendlier
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
70 ET23.5 E39 Mogul 67565 LU70/HgF/ECO S62 20 Clear Universal O 24000 6000 5100 22 2150 10,15
100 ET23.5 E39 Mogul 67558 LU100/HgF/ECO S54 20 Clear Universal O 24000 9500 8500 22 2150 10,15
150 ET23.5 E39 Mogul 67566 LU150/55/HgF/ECO S55 20 Clear Universal O 24000 15500 13200 22 2200 10,15,37,
38
LUMALUX STANDARD & LUMALUX ECO®
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
35 E17 E26 Med 67500 LU35/MED S76 20 Clear Universal O 16000+ 2250 2050 22 1900 10,39
67501 LU35/D/MED S76 20 Coated Universal O 16000+ 2100 1935 22 1900 10,39
50 E17 E26 Med 67502 LU50/MED S68 20 Clear Universal O 24000+ 4000 3600 22 1900 10,39
67503 LU50/D/MED S68 20 Coated Universal O 24000+ 3700 3420 22 1900 10,39
ET23.5 E39 Mogul 67510 LU50/ECO S68 20 Clear Universal O 24000+ 4000 3600 22 1900 10,15,39
67511 LU50/D S68 20 Coated Universal O 24000+ 3700 3420 22 1900 10,39
70 E17 E26 Med 67504 LU70/MED S62 20 Clear Universal O 24000+ 6300 5350 22 1900 10,39
67505 LU70/D/MED S62 20 Coated Universal O 24000+ 5800 4900 22 1900 10,39
ET23.5 E39 Mogul 67512 LU70/ECO S62 20 Clear Universal O 24000+ 6300 5500 22 1900 10,15,39
67513 LU70/D S62 20 Coated Universal O 24000+ 5500 4900 22 1900 10,39
100 E17 E26 Med 67506 LU100/MED S54 20 Clear Universal O 24000+ 9500 8000 22 2100 10,39
67507 LU100/D/MED S54 20 Coated Universal O 24000+ 8800 7500 22 2100 10,39
ET23.5 E39 Mogul 67514 LU100/ECO S54 20 Clear Universal O 24000+ 9500 8000 22 2100 10,15,39
67515 LU100/D S54 20 Coated Universal O 24000+ 8800 7500 22 2100 10,39
150 E17 E26 Med 67508 LU150/55/MED S55 20 Clear Universal O 24000+ 15800 13400 22 2100 10,37,38,39
Note: LCL = 3 7/16 in; MOL = 5 11/16 in
67509 LU150/55/D/MED S55 20 Coated Universal O 24000+ 14500 12300 22 2100 10,37,38,39
Note: LCL = 3 7/16 in; MOL = 5 11/16 in
ET23.5 E39 Mogul 67516 LU150/55/ECO S55 20 Clear Universal O 24000+ 16000 13800 22 2100 10,15,37,
39
67517 LU150/55/D S55 20 Coated Universal O 24000+ 14000 12500 22 2100 10,37,39
BT28 E39 Mogul 67518 LU150/100 S56 10 Clear Universal O 24000+ 15700 14100 22 2100 10,39,40
ET18 BT28, ET23.5 BT37 T (Mog base) E25 T (RSC base)
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
85
H
I
D
LUMALUX®HIGH PRESSURE SODIUM
LUMALUX STANDARD & LUMALUX ECO®
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
200 ET18 E39 Mogul 67576 LU200/ECO S66 20 Clear Universal O 24000+ 22000 19800 22 2100 10,15,39
250 BT28 E39 Mogul 67521 LU250/D S50 10 Coated Universal O 24000+ 26000 23400 22 2100 10,39
ET18 E39 Mogul 67578 LU250/ECO S50 20 Clear Universal O 24000+ 29000 26100 22 2100 10,15,39
310 ET18 E39 Mogul 67580 LU310/ECO S67 20 Clear Universal O 24000+ 37000 33300 22 2100 10,15,39
400 BT37 E39 Mogul 67524 LU400/D S51 10 Coated Universal O 24000+ 47500 40000 21 2100 10,39
ET18 E39 Mogul 67533 LU400/ECO S51 20 Clear Universal O 24000+ 50000 45000 22 2100 10,15,39
600 T16 E39 Mogul 67610 LU600 SUPER S106 12 Clear Universal O 24000 90000 81000 22 2200 41
750 BT37 E39 Mogul 67547 LU750 S111 6 Clear Universal O 24000+ 105000 94500 22 2100 39,41
Note: LCL = 6 7/8 in; MOL = 11 1/2 in
1000 E25 E39 Mogul 67307 LU1000 S52 6 Clear Universal O 24000+ 130000 124000 22 2100 39,41
LUMALUX STANDBY
Dual Arc Tube, Long Life
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
70 ET23.5 E39 Mogul 67540 LU70/SBY S62 20 Clear Universal O 40000 6050 4950 22 1900 10,42
100 ET23.5 E39 Mogul 67542 LU100/SBY S54 20 Clear Universal O 40000 9500 7600 22 2100 10,42
150 ET23.5 E39 Mogul 67544 LU150/55/SBY S55 20 Clear Universal O 40000 15700 12100 22 2100 10,37,38,42
200 ET18 E39 Mogul 67586 LU200/100/SBY S66 20 Clear Universal O 40000 21500 18000 22 2100 10,42
250 ET18 E39 Mogul 67582 LU250/SBY S50 20 Clear Universal O 40000 27500 23200 22 2100 10,42
400 ET18 E39 Mogul 67584 LU400/SBY S51 20 Clear Universal O 40000 47500 40000 22 2100 10,42
1000 E25 E39 Mogul 67543 LU1000/SBY S52 6 Clear Universal O 24000+ 127000 115000 22 2100 39,41
UNALUX®
High Pressure Sodium Retrofit for Mercury
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
150 BT28 E39 Mogul 67528 ULX150 S63 10 Clear Universal O 24000 11800 10600 20 1800 43
215 BT28 E39 Mogul 67530 ULX215 S65 10 Clear Universal O 16000 20000 17000 20 2000 43
360 BT37 E39 Mogul 67531 ULX360 S64 10 Clear Universal O 16000 36500 32800 20 2060 43
880 E25 E39 Mogul 67318 ULX880 6Clear Universal O 12000 101000 91000 20 2100 43,44
Note: LCL = 9 1/2 in; MOL = 15 1/16 in
SPECIALTY
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
400 T7 RX7S RRSC 67527 LU400T7/RSC S51 10 Clear HOR E 24000 46000 41400 21 2100 2,10
T14.5 E40 Mogul 67711 400W PLANTASTAR S51 12 Clear Universal O 16000 55000 50000 22 2000 41,45
600 T14.5 E40 Mogul 67712 600W PLANTASTAR S106 12 Clear Universal O 16000 90000 81000 22 2000 41,45
1000 E25 E39 Mogul 67314 LU1000/PLANTASTAR S52 6 Clear Universal O 24000 130000 124000 22 2100 41
T (BY22D base)
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
86
H
I
D
SOX LOW PRESSURE SODIUM
8Avg Approx
|
Product ANSI Pkg Lamp Operating Fix Rated Lumens CCT MOL Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life(hrs) (initial) (K) (in) Footnotes
|
18 T17 BY22D 69510 SOX18 L69 12 Clear BU ± 110° E 16000 1800 1800 8.5
35 T17 BY22D 69511 SOX35 L70 12 Clear BU ± 110° E 16000 4500 1800 12.24
55 T17 BY22D 69512 SOX55 L71 12 Clear BU ± 110° E 16000 7300 1800 16.73
90 T21 BY22D 69513 SOX90 L72 12 Clear HOR ± 20° E 16000 13500 1800 20.79
135 T21 BY22D 69514 SOX135 L73 12 Clear HOR ± 20° E 16000 22000 1800 30.51
180 T21 BY22D 69515 SOX180 L74RF 9 Clear HOR ± 20° E 16000 30000 1800 44.1
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
87
GUIDE TO MERCURY VAPOR LAMPS
OSRAM SYLVANIA Mercury lamps are designed primarily for use in general light-
ing applications where good efficiency and long life are desired while color ren-
dering requirements are moderate. Applications include street lighting, industrial
hi-bay, parking lot lighting, and general flood-lighting.
STANDARD MERCURY — Available in a wide range of lamp types from 40-1000
watts, in both clear and coated configurations, Mercury vapor lamps are ideal for
a variety of lighting applications. PAR lamps offer floodlighting and ultra-violet
spectra for special lighting applications.
MERCURY SAFELINE®Designed to self extinguish when the outer bulb is bro-
ken, Mercury Safeline lamps are recommended for use in fixtures installed in
sports facilities and other places of public assembly where lamps may be subject
to breakage by external objects.
STANDARD MERCURY “R” LAMPS
I. RUPTURE RISKS: This Mercury lamp is constructed of an outer glass bulb with an internal arc-tube made of quartz. Mercury arc-tubes operate at high pressure
and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rup-
ture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot quartz particles. In the event of such rupture,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
2. Fixture lens/diffuser material must be able to contain hot lamp fragments (as high as 1832˚F, 1000˚C). If you are uncertain, contact your fixture
manufacturer.
3. Never expose an operating lamp to moisture (such as rain, sleet, or snow).
4. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
5. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
6. Replace lamp at or before the end of rated life. (See catalog for rated life.)
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INFLAMMATION FROM SHORT WAVE ULTRAVIOLET RADIATION IF OUTER
ENVELOPE OF THE LAMP IS BROKEN OR PUNCTURED. DO NOT USE WHERE PEOPLE WILL REMAIN FOR MORE THAN A FEW MINUTES
UNLESS ADEQUATE SHIELDING OR OTHER SAFETY PRECAUTIONS ARE USED. LAMPS THAT WILL AUTOMATICALLY EXTINGUISH WHEN THE
OUTER ENVELOPE IS BROKEN OR PUNCTURED ARE COMMERCIALLY AVAILABLE.
THIS PRODUCT CONFORMS TO THE FOLLOWING FEDERAL REGULATIONS:
U.S.A.: 21 CFR 1040.30 CANADA: SOR/80-381
IV. INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. To avoid damaging a lamp, never install it into an ordinary household socket.
3. This lamp may be operated in any position.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
WARNING
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
88
MERCURY SAFELINE®
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Mercury lamp is constructed of an outer glass bulb with an internal arc-tube made of quartz. Mercury arc-tubes operate at high pressure
and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rup-
ture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot quartz particles. In the event of such rupture,
THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.)
2. Fixture lens/diffuser material must be able to contain hot lamp fragments (as high as 1832˚F, 1000˚C). If you are undertain, contact your fixture
manufacturer.
3. Never expose an operating lamp to moisture (such as rain, sleet, or snow).
4. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
5. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
6. Replace lamp at or before the end of rated life. (See catalog for rated life.)
II. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
III. ULTRAVIOLET RADIATION EXPOSURE:
WARNING: This lamp should self-extinguish within 15 minutes after the outer envelope is broken or punctured. If such damage occurs, TURN OFF AND REMOVE
LAMP to avoid possible injury from hazardous shortwave ultraviolet radiation.
THIS PRODUCT CONFORMS TO THE FOLLOWING FEDERAL REGULATIONS:
U.S.A.: 21 CFR 1040.30 CANADA: SOR/80-381
IV. INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. To avoid damaging a lamp, never install it into an ordinary household socket.
3. This lamp may be operated in any position.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
WARNING
H
I
D
E17 ET23.5, BT28 PAR38 R30/R40 T (Mog base) BT56 BT37
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
89
H
I
D
MERCURY
MERCURY STANDARD
9Avg Arc
|
Product ANSI Pkg BeamBeam Lamp Operating Fix Rated Approx Lumens CCT Length Symbols &
|
Watts Bulb Base Number OrderingAbbreviation Code Qty Type Angle Finish Position Req Life (hrs) (initial) (mean) CRI (K) (in) Footnotes
|
40 E17 E26 Med 69400 H45/46DL-40/50/DX H45/H46 20 Coated Universal 24000+ 1580 1300 45 4000 39,46,47
Note: LCL = 3 1/8 in; MOL = 5 1/8 in
75 E17 E26 Med 69402 H43AV-75/DX H43 20 Coated Universal 24000+ 2700 1800 45 4300 39,47
100 E17 E26 Med 69403 H38AV-100/DX H38 20 Coated Universal 24000+ 4000 3560 45 4000 39,47
ET23.5 E39 Mogul 69407 H38HT-100 H38 20 Clear Universal 24000+ 4000 3000 22 5900 39,47
69408 H38JA-100/DX H38 20 Coated Universal 24000+ 4100 3300 45 4000 39,47
PAR38 AD Med Skt 68843 H44GS-100SP H44 12 SP 8 Universal 16000 2500 1950 20 5900
E26 Med Skt 68846 H44JM-100/MDSKSP H44 12 SP 8 Universal 16000 2500 1950 20 5900
R40 E26 Med 69405 H38BP-100/DX H38 10 FL Coated Universal 24000+ 2500 2000 45 4000 39,47
175 ED28 E39 Mogul 69444 H39KB-175 H39 6 Clear Universal 24000+ 7700 7150 22 5900 39,47
69445 H39KC-175/DX H39 6 Coated Universal 24000+ 8400 6800 45 4000 39,47
R40 E26 Med 69406 H39BP-175/DX H39 10 FL Coated Universal 24000+ 5100 4100 45 4000 39,47
250 ED28 E39 Mogul 69447 H37KB-250 H37 6 Clear Universal 24000+ 11600 10800 22 5900 39,47
69448 H37KC-250/DX H37 6 Coated Universal 24000+ 12500 10000 45 4000 39,47
400 ED37 E39 Mogul 69449 H33CD-400 H33 6 Clear Universal 24000+ 20000 18700 22 5900 39,47
69450 H33GL-400/DX H33 6 Coated Universal 24000+ 23000 16200 43 4000 39,47
T16 E39 Mogul 68893 H33AR-400 H33 6 Clear Universal 12000 19500 16500 16 5900 47
1000 BT56 E39 Mogul 69332 H34GW-1000/DX H34 6 Coated Universal 16000+ 55000 44000 45 4000 39,47,48
69307 H36GV-1000 H36 6 Clear Universal 24000+ 55200 50000 22 5900 39,47,48
69331 H36GW-1000/DX H36 6 Coated Universal 24000+ 58000 48500 45 4000 39,47,48
MERCURY SAFELINE®
Self-Extinguishing
4Avg
|
Product ANSI Pkg Lamp Operating Fix Rated Approx Lumens CCT Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Code Qty Finish Position Req Life (hrs) (initial) (mean) CRI (K) Footnotes
|
400 BT37 E39 Mogul 69451 H33GL-T400/DX H33 6 Coated Universal 24000+ 19800 16000 45 4000 39,47
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
90
GUIDE TO REPROGRAPHIC / PHOTOCHEMICAL LAMPS
OSRAM SYLVANIA reprographic and
photochemical lamps are designed for applications
other than general lighting. These applications
include: plate making, photo resist exposure,
imaging and other requiring the use of ultraviolet
energy.
UNJACKETED REPROGRAPHIC / PHOTOCHEMICAL, F-TYPE LAMP
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This High Intensity Discharge (HID) lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures.
The arc-tube can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication resulting in the discharge of glass frag-
ments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer.
2. Only operate lamp with compatible ballast (including capacitor and ignitor) and fixture.
3. Only operate lamp in horizontal position (Maximum deviation from horizontal is 15°).
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose an operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if bulb is scratched, cracked or damaged in any way.
7. Keep all metals at least 3 inches from the body of the arc-tube to avoid glass decomposition.
8. Do not operate lamps when output radiation falls below 75% of its initial value.
II. ULTRAVIOLET RADIATION HAZARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 3 PER ANSI-IESNA Rp-27.3-
96. THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INFLAMMATION FROM SHORTWAVE ULTRAVIOLET RADIATION. KEEP OUT OF DIRECT OR INDI-
RECT LIGHT DURING OPERATION UNLESS APPROPRIATE EYE AND SKIN PROTECTION IS WORN. A POWER INTERLOCK DEVICE IS RECOMMENDED TO AUTO-
MATICALLY TURN OFF THE LAMP IF THE FIXTURE ASSEMBLY IS OPENED.
DUE TO THE ULTRAVIOLET HAZARD, THIS LAMP IS TO BE USED ONLY IN EQUIPMENT SPECIFICALLY DESIGNED FOR USE WITH THIS LAMP AND RECOM-
MENDED FOR ITS USE BY THE EQUIPMENT MANUFACTURER.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing.
IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled,
fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and
premature lamp failure. Dry lamp carefully with clean cotton cloth.
1. Install lamps without undue pressure.
2. Ensure that lamp electrical connections are secure and nothing is touching bulb.
3. The seal base temperature must not exceed 350° C and the bulb wall temperature, as measured in center, must be maintained between 600° C and 700° C.
4. If cooling is required to maintain the seal/base and the bulb wall temperatures of item 3 above, air interlock vane switches are recommended to protect against
fan-motor failure.
5. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp.
6. Fixture wiring must have a temperature rating of 250° C and a minimum voltage rating of 600V RMS for lamps of less than 1000 watts and 1500V RMS for
lamps of 1000 watts or greater.
7. For maximum performance, all double-ended lamps must be operated with the arc-tube tip up.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
H
I
D
TUNGSTEN
ELECTRODES
BASE
QUARTZ BULB
MOLYBDENUM
FOIL
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
91
JACKETED REPROGRAPHIC / PHOTOCHEMICAL, E-TYPE LAMP
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This High Intensity Discharge (HID) lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures.
The arc-tube can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can burst and
shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSON-
AL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
TO REDUCE THESE RISKS:
1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012°F, 1100°C). If you are uncertain,
contact your fixture manufacturer.
2. Only operate lamp with compatible ballast (including capacitor and ignitor) and fixture.
3. Only operate lamp in horizontal position. (Maximum deviation from horizontal is 15°).
4. Lamp must be turned off for a minimum of fifteen minutes at least once a week.
5. Never expose operating lamp to moisture (such as rain, sleet or snow).
6. Replace lamp if outer glass bulb is scratched, cracked or damaged in any way.
7. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition.
8. Do not operate lamps when output radiation falls below 75% of its initial value.
II. ULTRAVIOLET RADIATION EXPOSURE: THIS LAMP CAN CAUSE SERIOUS SKIN BURN AND EYE INFLAMMATION FROM SHORTWAVE ULTRAVIOLET RADIATION
IF THE OUTER ENVELOPE OF THE LAMP IS BROKEN OR PUNCTURED. DO NOT USE WHERE PEOPLE WILL REMAIN FOR MORE THAN A FEW MINUTES UNLESS
ADEQUATE SHIELDING OR OTHER SAFETY PRECAUTIONS ARE USED.
III. ELECTRICAL SHOCK AND BURN HAZARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and
remove lamp after it has cooled.
IV. LAMP INSTALLATION:
1. Screw lamp firmly but not forcibly into socket to avoid breakage.
2. Never install the lamp into an ordinary household socket.
V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See
Product Safety Data Sheet for further details.
H
I
D
T (RSC base) ET23.5, BT28 ET18 BT37
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 93-94
92
H
I
D
REPROGRAPHIC / PHOTOCHEMICAL
REPROGRAPHIC
10 Arc
|
Product Pkg Operating Fix MOL Length Primary Line(s) Symbols &
|
Watts Bulb Base Number Ordering Abbreviation Qty Position Req (in) (in) of Emission Footnotes
|
400 T5.5 J 66621 MP400T5.5/1.5J 10 HOR ± 15° F 4.5 1.375 417nm 29,31,49
1200 T5.5 J 66573 MP1200T5.5/6J 10 HOR ± 15° F 9 6 417nm 29,31,49
3000 T8 J 66562 MP3000T8/6J 10 HOR ± 15° F 9.375 5.75 417nm 29,31,49
LAMP & BALLAST SYSTEM
23 Ballast Lamp
|
Product ANSI Pkg Product Ballast Voltage Circuit Product Lamp Fix Symbols &
|
Watts Number Ordering Abbreviation Code Qty Number (VAC) Type Number Bulb Base Finish Req Footnotes
|
100 67621 LU100/ECO LAMP/MULTI-BALLAST KIT S54 1 47316 120/208/240/ CWA 67514 ET23.5 E39 Clear 10
277 Mogul
150 67629 LU150/55/ECO LAMP/MULTI BALLAST KIT S55 1 47335 120/208/240/ CWA 67516 ET23.5 E39 Clear 10
277 Mogul
175 64782 M175/U LAMP/SUPER5 BALLAST KIT M57/E 1 47243 120/208/240/ CWA 64471 BT28 E39 Clear E 2
277/480 Mogul
250 67622 LU250/ECO LAMP/SUPER5 BALLAST KIT S50 1 47634 120/208/240/ CWA 67578 ET18 E39 Clear 10
277/480 Mogul
64784 M250/U LAMP/SUPER5 BALLAST KIT M58/E 1 47265 120/208/240/ CWA 64457 BT28 E39 Clear E 2
277/480 Mogul
400 67623 LU400/ECO LAMP/SUPER5 BALLAST KIT S51 1 47647 120/208/240/ CWA 67533 ET18 E39 Clear 10
277/480 Mogul
64781 M400/U LAMP/SUPER5 BALLAST KIT M59/S 1 47338 120/208/240/ CWA 64490 BT37 E39 Clear S 20
277/480 Mogul
For more complete product information visit www.sylvania.com 93
SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal
regulations may vary; check local and state regulations.
This lamp is a High Color Rendering Lamp
Footnote Description
1Consult your OSRAM SYLVANIA Lighting Representative for compatible electronic operating systems.
2E = Lamps classified as E-type are to be used ONLY in suitably enclosed luminaries. See lamp warning.
3The circuit must include overcurrent protection (I.e. Thermally switched ballast).
4Lamp requires a nominal Open Circuit Voltage of 230V or higher. Without an ignitor in the circuit minimum OCV is 209Vrms.
5UV-Stop quartz
6Lamps may be operated on ANSI M98 Compliant Ballast.
7Lamps may be operated on ANSI M85 or M98 Compliant ballasts.
8Lamps may be operated on a M142 Compliant ballast.
9Lamps may be operated on ANSI M142 or M81 Compliant ballasts.
10 Use with 4000V pulse rated sockets only.
11 O = Lamps classified as O-type, comply with ANSI standard C78.387 for containment testing and may be used in open luminaries. See lamp
warning.
12 Lamps may be operated on ANSI M140 Compliant Ballast.
13 When operated on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced.
14 Beam angle conversion from 30 to 40 degrees in April 2004. Engineering estimate for CBCP is 10000.
15 Passes Federal TCLP test based on NEMA LL Series Standards. TCLP data available upon request. Disposal regulatioins may vary depending
on location. Please check your local and state regulations
16 Lamps with a E26 medium skirt base are not compatible with exclusionary medium sockets.
17 Lamps may be operated on ANSI M132 (320W) Compliant ballasts.
18 Lamps may be operated on ANSI M135 (400W) Compliant ballasts.
19 20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 120 hrs/start.
20 S = When operated within 15 degrees of vertical, this lamp may be operated in an open luminaire provided the installation is not near people
or flammable or combustible material, otherwise it must be operated in a suitably enclosed luminaire. See lamp warning.
21 When operating on a ballast with a sustaining voltage less than 310V, lamp life may be significantly reduced.
22 Operates at 150W on a 175W M57 ballast or a M107 ballast.
23 Please consult your ballast and fixture manufacturer for compatible systems.
24 Operates at 360 watts on 400w M59 ballast or a M165 ballast.
25 Horizontally oriented lamps require a position oriented mogul (POM) socket to accept position oriented mogul bases.
26 Lamps may be operated M155 or M135 pulse start ballast with a sustaining voltage greater than 270V. Performance will be as rated on a
M59 ballast.
27 Lamps may be operated on ANSI M137 Compliant ballasts.
28 Published rated life based on 5 hours per start. Life rating will increase to 6,000 hours if operated for at least 10 hours per start in the base
position. Lumens will be lower for operating positions other than base up. See lumen tilt factor curve.
29 Use in equipment where gasket material is protected from all lamp radiation.
30 Consult your OSRAM SYLVANIA Lighting Representative for lamp/ballast compatibility.
31 F = Enclosed luminaire with UV filter and lens interlock required. WARNING: This lamp emits ultraviolet radiation which can cause serious
skin burn and eye inflammation. Additionally, this lamp operates under high pressure at very high temperatures. Should the lamp break
there can exist a danger of personal injury and/or fire from the broken lamp particles being discharged. This lamp should only be used in
fully enclosed luminaire with ultraviolet (UV) filter tempered glass lens capable of containing any particles discharges by breakage. Do not
use this lamp if the filter lens is damaged or missing. This lamp should only be used in luminaires equiped with safety interlock lens switch-
es. See lamp warning.
32 For use where seal temperature does not exceed 350˚ C.
33 Lamps must be operated on CW/CWA ballasts only
H
I
D
For more complete product information visit www.sylvania.com
94
SYMBOLS & FOOTNOTES FOR HIGH INTENSITY DISCHARGE (HID) LAMPS
Footnote Description
34 Requires POWERTRONIC Ballast.
35 Requires 3000V minimum pulse.
36 Voltage rise due to fixture effect is to be evaluated using standard lamp types and not LUMALUX PLUS®/ECO®or LUMALUX®MERCURY
FREE/ECO lamp types.
37 55 Volt lamp.
38 LU150/100 and LU150/55 lamps are not interchangeable.
39 Mean lumens measured at 50% of average rated life
40 100 Volt lamp.
41 Use with 5000V pulse rated sockets only.
42 Standby feature not guaranteed beyond 24,000 operating hours.
43 UNALUX®lamps must be operated on mercury lag or reactor ballasts only.
44 The ULX880 lamp should not be used on any circuit other than 480V H36 mercury reactor.
45 Use with 4-5kV ignitor.
46 Operates at 40 watts on H45 ballast, 50 watts on H46 ballast.
47 In general, Horizontal lumen values will be 5-10% lower than the vertical lumen values.
48 H34 and H36 lamps are not interchangeable.
49 Unjacketed reprographical/photochemical lamp.
H
I
D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
95
OSRAM SYLVANIA: THE LEADER IN
ENERGY SAVING FLUORESCENT LAMPS
The fluorescent lamp is an electric discharge device which utilizes a low pressure mercury vapor arc to generate ultra-violet
(plus a little visible) energy. The ultra-violet energy is absorbed by a phosphor coat on the inside of the glass tube
and converted by the phosphor to visible wavelengths; the wavelengths of the light generated are determined by the
composition of the phosphor. In addition to the small amount of mercury vapor, the fluorescent tube contains an
atmosphere of an inert gas, usually argon, krypton, neon, or a mixture of two or more of these gases. The pressure
of the gases contained in the lamp is very low, usually from 2 to 3 torr. Atmospheric pressure is 760 torr.
F
L
U
O
R
E
S
C
E
N
T
Usually straight glass tube.
May also be circular or U-
shaped.
Several different types
used to connect the
lamp to the electric cir-
cuit and to support the
lamp in the lampholder.
Connect to the base pins
and carry the current to
and from the cathodes
and the mercury arc.
The lead-in wires have
an air tight seal here
and are made of specif-
ic wire to assure about
the same coefficient of
expansion as the glass.
Usually argon or a mix-
ture of inert gases at
low pressure. Krypton
is sometimes used.
A minute quantity of
liquid mercury is
placed in the bulb to
furnish mercury vapor.
Air is exhausted
through this tube dur-
ing manufacture and
inert gas introduced
into the bulb.
“Hot cathodes” at each end
of lamp are coated with
emissive materials which
emit electrons. Usually
made of coiled-coil or single-
coil tungsten wire.
Coating inside the bulb
transforms ultraviolet radi-
ation into visible light.
Color of light produced
depends on composition
of phosphor.
BULB
BASE MERCURY GAS STEM PRESS LEAD-IN WIRES
EXHAUST TUBE
PHOSPHOR CATHODE
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
96
HOW TO READ PRODUCT INFORMATION - COMPACT FLUORESCENT
AvgAvg Approx Lumens
|
Nominal MOL Product NEMA Generic Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
20 T4 6.3 160 Med 29296 CF20EL/830/MED 6 6000 3000 82 1280 1101 2,21,28,
36,63,64
26 T4 6.8 173 G24D-3 20710 CF26DD/830 CFQ26W/G24D/30 50 10000 3000 82 1800 1548 2,21,28,
34,37
32 T4 5.5 140 GX24Q-3 20885 CF32DT/E/IN/835 CFTR32W/GX24Q/35 50 10000 3500 82 2400 2064 2,21,28,
33,35,59
40 T5 22.6 573 2G11 20586 FT40DL/841/RS FT40W/2G11/RS/41 10 20000 4100 82 3150 2709 2,21,28
Nominal Wattage Design wattage on reference ballast. Actual wattage dependent on ballast.
Bulb Describes the shape of the bulb followed by the bulb’s diameter at its widest point. The diameter value is expressed in eighths
of an inch. Ex. T = Tubular, 4 = 4/8 inch = 1/2 inch. Please see page 103 for bulb illustrations.
Base Base designations for compact fluorescent lamps are the NEMA designations. Please see page 104 for base illustrations.
MOL Maximum overall length. The actual length of the lamp measured from the bottom of the base to the top outside edge of the
glass. In many cases, the bottom of the base is the bottom of the center post of the base of the lamp.
Symbols & Footnotes Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
footnotes are at the end of the fluorescent section.
Ordering Abbreviation A text description of the lamp. Please see below for several examples and explanations of some of the codes.
NEMA Generic Designation assigned by NEMA (National Electrical Manufacturers Association).
Designation
CCT Correlated Color Temperature. The degree of “whiteness” of the light. Expressed in kelvins (K).
Please see page 99 for more information.
CRI Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to
a standard. Please see page 99 for more information.
Initial & Mean Lumens Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at
40% of the rated life of the lamp. Compact Fluorescent lamp lumens are measured at 25°C (77°F).
How to Read Ordering Abbreviations
CF26DD/830 CF32DT/E/IN/835 FT40DL/841/RS CF20EL/830/MED
CF Compact Fluorescent CF Compact Fluorescent FT Fluorescent Twin CF Compact Fluorescent
26 Nominal lamp wattage 32 Nominal lamp wattage 40 Nominal lamp wattage 20 Nominal lamp wattage
DD DULUX Double DT DULUXTriple DL DULUX Long EL Electronic Lamp
882 CRI E Electronic or dimming 8 82 CRI 8 82 CRI
30 3000K CCT operation 41 4100K CCT 30 3000K CCT
IN Amalgam RS Rapid Start MED Medium screw base
882 CRI
35 3500K CCT
DULUX®LAMP FAMILIES
CF... DS = DULUX Single, 2-pin for magnetic operation, ECOLOGIC®
CF... DS/E = DULUX Single, 4-pin for electronic or dimming operation
CF... DD = DULUX Double, 2-pin for magnetic operation, ECOLOGIC
CF... DD/E = DULUX Double, 4-pin for electronic or dimming operation, ECOLOGIC
CF... DT = DULUX Triple, 2-pin for magnetic operation, ECOLOGIC
CF... DT/E = DULUX Triple, 4-pin for electronic or dimming operation, ECOLOGIC
CF... DT/E/IN = DULUX Triple, 4-pin for electronic or dimming operation, amalgam, ECOLOGIC
FT... DL = Fluorescent Twin, DULUX Long, 4-pin
CF... DF = DULUX Flat, 4-pin
CF... EL = DULUX self-ballasted, medium screw base
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
97
HOW TO READ PRODUCT INFORMATION - FLUORESCENT
Avg Approx Lumens
|
Avg Initial Mean
|
Nominal Nominal MOL Product Pkg Rated CCT @25°C/77°F Symbols &
|
Wattage Bulb Length(in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI (@35˚C/95˚F) Footnotes
|
32 T8 48 47.78 Med Bipin 21763 FO32/835XP/ECO 30 24000 3500 85 3000 2850 2,21,31,
35,39,60,70
34 T12 48 47.78 Med Bipin 24594 F34CW/SS 30 20000 4200 62 2650 2279 2,10,13,
Formerly F40CW/SS 19,21,42
54 T5 48 45.5 Mini Bipin 20857 FP54/830/HO 40 20000 3000 82 4450 4228 2,21,26,35,59
5000 4750
60 T12 96 94 Single Pin 29815 F96T12/CW/SS 15 12000 4200 62 5300 4664 2,15,21
Nominal Wattage Design wattage on reference ballast. Actual wattage dependent on ballast.
Bulb Describes the shape of the bulb followed by the bulb’s diameter at its widest point. The diameter value is expressed in eighths of
an inch. Ex. T = Tubular, 8 = 8/8 inch = 1 inch. Please see page 103 for bulb illustrations.
Base Please see page 104 for base illustrations.
Nominal Length The nominal length of linear fluorescent lamps is typically measured from back of lampholder to back of lampholder.
PENTRON®linear lamp, CURVALUME® and Circline lamps are exceptions. The nominal length given for PENTRON linear lamps
is the closest familiar nominal length. CURVALUME lamps are measured from the face of the bases to the outside of the glass
bend. The measurement for Circline lamps is the outside diameter. Values are in inches.
MOL Maximum overall length. The length of the lamp measured in inches.
Symbols & Footnotes Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and
footnotes are at the end of the fluorescent section.
Ordering Abbreviation A text description of the lamp. Please see below for several examples and explanations of some of the codes.
CCT Correlated Color Temperature. The degree of “whiteness” of the light. Expressed in kelvins (K).
Please see page 99 for more information.
CRI Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to a
standard. Please see page 99 for more information.
Initial & Mean Lumens Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at 40% of
the rated life of the lamp. For longer life lamp such as the OCTRON® XPlamps, the mean lumens are measured at the same
point in time as they are measured for the standard lamps they replace. Fluorescent lamp lumens are typically measured at
25˚C (77˚F). The lamp lumens are measured at both 25˚C (77˚F) and 35˚C (95˚F) for PENTRON linear lamps.
How to Read Ordering Abbreviations
FO32/835XP/ECO F34CW/SS FP54/830/HO F96T12/CW/SS
FFluorescent F Fluorescent F Fluorescent F Fluorescent
OOCTRON 34 Nominal lamp P PENTRON 96 96" nominal length
32 Nominal lamp wattage 54 Nominal lamp T Tubular Shape Bulb
wattage CW Cool White wattage 12 Bulb diameter;
885 CRI phosphor 8 82 CRI 128inch = 1 12inches
35 3500K CCT SS SUPERSAVER®-303000K CCT CW Cool White phosphor
XP EXtended reduced wattage HO High Output SS SUPERSAVER -
Performance lamp reduced wattage lamp
ECO®ECOLOGIC®-
TCLP passing lamp
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
98
The following items were accepted into the 2003 IESNA Progress Report which recognizes innovative products
introduced to the industry during that year.
OCTRON®28-watt 4-foot XPSUPERSAVER®
OCTRON 8-foot XP SUPERSAVER
OCTRON CURVALUME®XP SUPERSAVER
5000K ICETRON®
Colored PENTRON®
For weight and measurement information, please visit www.sylvania.com
F
L
U
O
R
E
S
C
E
N
T
Lamp Disposal Labeling
The following information appears on the packages of fluorescent lamps. For more information on lamp disposal labeling, see the
inside back cover of this catalog.
Lamp Contains Mercury
Hg Manage in accordance with disposal laws
See www.lamprecycle.orgor 1-866-666-6850
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
99
FLUORESCENT LAMP COLORS
CORRELATED COLOR
COLOR COLOR RENDERING
COLOR ABBREVIATION TEMPERATURE(1) INDEX(2)
DULUX®2700K 827 2700 82
OCTRON®"800" 2700K 827 2700 84
OCTRON XP™ "800" 2700K 827 2700 85
INCANDESCENT FLUORESCENT IF 2750 89
SOFT WHITE Soft White 2900 82
DELUXE WARM WHITE WWX 2900 82
WARM WHITE WW 3000 52
WARM WHITE PLUS WWP 3000 70
DESIGNER®3000K D30 3000 70
DESIGNER WARM WHITE DWW 3000 70
DESIGNER "800" 3000K D830 3000 80
DESIGNER WARM WHITE PLUS DWWP 3000 80
DULUX SOFT WHITE 830 3000 82
DULUX 3000K 830 3000 82
OCTRON "700" 3000K 730 3000 75
OCTRON XP "700" 3000K 730 3000 78
OCTRON "800" 3000K 830 3000 82
OCTRON XP "800" 3000K 830 3000 85
OCTRON XPS®"800" 3000K 830 3000 86
PENTRON®3000K 830 3000 82
GRO-LUX®Aquarium WIDE SPECTRUM GRO/AQ/WS 3400 89
WHITE W 3450 57
DESIGNER 3500K D35 3500 70
DESIGNER "800" 3500K D835 3500 80
DULUX 3500K 835 3500 82
ICETRON®3500K 835 3500 80
PENTRON 3500K 835 3500 82
OCTRON "700" 3500K 735 3500 75
OCTRON XP "700" 3500K 735 3500 78
OCTRON "800" 3500K 835 3500 82
OCTRON XP "800" 3500K 835 3500 85
OCTRON XPS "800" 3500K 835 3500 86
NATURAL WHITE N 3600 86
DESIGNER 4100K D41 4100 70
DESIGNER COOL WHITE DCW 4100 70
DESIGNER "800" 4100K D841 4100 80
DESIGNER COOL WHITE PLUS DCWP 4100 80
DULUX 4100K 841 4100 82
ICETRON 4100K 841 4100 80
PENTRON 4100K 841 4100 82
OCTRON "700" 4100K 741 4100 75
OCTRON XP "700" 4100K 741 4100 78
OCTRON "800" 4100K 841 4100 82
OCTRON XP "800" 4100K 841 4100 85
OCTRON XPS "800" 4100K 841 4100 86
DELUXE COOL WHITE CWX 4100 87
LITE WHITE LW 4150 48
COOL WHITE CW 4200 62
COOL WHITE PLUS CWP 4100 70
DULUX 5000K 850 5000 82
ICETRON 5000K 850 5000 80
OCTRON "700" 5000K 750 5000 75
OCTRON "800" 5000K 850 5000 80
OCTRON XP "800" 5000K 850 5000 85
OCTRON "900" 5000K 950 5000 90
DESIGN 50®DSGN50 5000 90
DAYLIGHTD 6500 76
OCTRON "700" 6500K 765 6500 75
OCTRON XP "800" 6500K 865 6500 85
DESIGNER 6500K 865 6500 80
DAYLIGHT DELUXE DX 6500 88
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
100
FLUORESCENT COMPETITIVE GUIDES
NOTE: These tables are intended only as guides and may represent another lamp company’s most similar product or product family rather
than an identical match. Individual manufacturer’s performance values should be consulted. Environmental conditions, ballast type, and other
auxiliary equipment may affect lamp performance.
FLUORESCENT BRAND NAMES
SYLVANIA GE* PHILIPS**
CURVALUME®(FB) MOD-U-LINE (U) U-Bent (FB)
CWX Home Light Everywhere (HL Everywhere)
DESIGN 50®(DSGN50) Chroma 50 (C50) Colortone 50 (C50)
DESIGNER®Series Specification Series (SP) SPEC
DESIGNER 800 Series Specification Series (SPX) Ultralume
DESIGNER Cool White SP41 Home Light Cool (HL Cool)
DESIGNER Cool White PLUS SPX41 41U
DESIGNER Warm White Kitchen and Bath ULTRA (70 CRI) SPEC30
DESIGNER Warm White PLUS (DWWP) Kitchen and Bath ULTRA (80 CRI) Home Light WX (HL WX)
DESIGNER 700, 3500K (D35) SP35 Home Light Warm (HL Warm)
DULUX®BIAX PL
DULUX S BIAX PL
DULUX D, D/E Double BIAX PL-C
DULUX T, T/E Triple BIAX PL-T
DULUX F --- ---
DULUX L High Lumen BIAX PL-L
DULUX EL Electronic Self Ballasted Lamps(was Compax) Earth Light Lamps (SLS)
--- 2D ---
--- GENURA ---
ECOLOGIC®(ECO®)Ecolux (ECO) ALTO
GRO-LUX®Gro & Sho/Plant & Aquarium/Terrarium Agro-Lite (AGRO)
ICETRON®--- ---
OCTRON®T8 (was Trimline) TL70/TL80
OCTRON 700 XPECO SP Ecolux XL T8 Lamps with Starcoat TL700 PLUS ALTO
OCTRON 800 XP ECO SPX Ecolux XL T8 Lamps with Starcoat TL800 PLUS ALTO
OCTRON 800 XPS ECO --- ---
OCTRON 950 --- TL950
PENTRON®T5 Starcoat SILHOUETTE
--- --- QL (similar to ICETRON, but not interchangeable
SAFELINE®covRguard ---
SUN STICK®SUN (Sunshine) C50
SUPERSAVER®(SS) Watt-Miser (WM) Econ-o-Watt (EW)
HO (800mA) HO (800mA) HO (800mA)
VHO (1500mA) 1500 (1500mA) & Power Grove VHO (1500mA) (was SHO)
VHO/LT T10/1500MA VHO-0
XPXL Advantage
XPS®
*Trademarks or registered trademarks of General Electric Company ** Trademarks or registered trademarks of Philips
FLUORESCENT COLOR CROSS REFERENCE
SYLVANIA GE PHILIPS SYLVANIA GE PHILIPS
CW CW CW D41 SP41 Spec 41
CWX CWX, HL Everywhere SP65
DDDD830 SPX30 30U
DX DX DX D835 SPX35 35U
DSGN50 C50 50 D841 SPX41 41U
DSGN50 SGN C50 D865
DCW, D41 SP41 HL Cool 730 SP30 730
DCWP SPX41 U41 735 SP35 735
DWW, D30 KB / 70 CRI, SP30 SPEC30 741 SP41 741
DWWP, D830 KB / 82 CRI, SPX30 HL WX 750 SP50 750
D35 SP35 HL Warm 765 SP65
GRO/AQ AGRO 827 SPX27 27
GRO/WS/AQ PL/AQ 830 SPX30 30, 830
LW LW LW 835 SPX35 35, 835
NN N 841 SPX41 41, 841
SUN STICK SUN C50 850 SPX50 50, 850
WW WW WW 865 SPX65 865
D30 SP30 Spec 30 950 950
D35 SP35 Spec 35
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
101
FLUORESCENT COMPETITIVE GUIDES (continued)
FLUORESCENT ELECTRICAL INTERCHANGEABILITY
SYLVANIA GE PHILIPS
Linear Lamps
F18T8/CW/K/23 F24"T8/CW/4 F15T8/CW/24
F18T8/CW/K/26 F26"T8/CW/4 F16T8/CW/26
F18T8/CW/K/28 F28"T8/CW/4 F17T8/CW/28
F18T8/CW/K/30 F30"T8/CW/4 F18T8/CW/30
F34CW/SS F34CW/WM F34CW/EW
Formerly known as F40CW/SS F40CW/WM F40CW/EW
F96T12/CW/SS F96T12/CW/WM F96T12/CW/EW
FB40/D41/6 F40/SP41/U/6 FB40/SPEC41/6
FB40/CW/6/SS (new FB34/CW/6/SS) F40CW/U/6/WM (new F34CW/U/6/WM) FB40/CW/6/EW (new F34/CW/6/EW)
OCTRON®T8 (was Trimline) TL70/TL80
OCTRON 700 Series T8 SP TL70
OCTRON 800 Series T8 SPX TL80
FO17… F17T8/SP(or SPX)… F17T8/TL…
FO25… F25T8/SP(or SPX)… F25T8/TL…
FO32… F32T8/SP(or SPX)… F32T8/TL…
FO32/...XPF32T8/XL/SP (or SPX) F32T8/TL...PLUS
FO32/.../XPS®/ECO®--- ---
FO30…XP/SS/ECO F32T8/SP…/IS/WM/ECO F32T8/ADV8.../EW
FO28/8..XP/SS/ECO --- ---
FO40… F40T8/SP… (or SPX) F40T8/TL
FO72… --- ---
FO96… F96T8/SP… (or SPX) F96T8/TL…
FO96/7…XP/ECO F96T8/XL.SP... ---
FO96/8…XP/ECO F96T8/XL/SPX... ---
FO96/8...XP/SS/ECO F96T8/SP…/WM ---
--- --- F48T8/TL…/HO
--- --- F60T8/TL…/HO
--- --- F72T8/TL…/HO
FO96…/HO F96T8/SP (or SPX)…/HO F96T8/TL…/HO
--- F25T12/SP… (for T8 electronic ballasts) ---
FBO16… --- ---
FBO24… --- ---
FBO31… F31T8/SPX…/U ---
FBO31…XP --- ---
FBO32… F32T8/SP(or SPX)…/U6 FB32T8/TL…/6
FBO32…XP --- ---
FBO31/...XPS/ECO --- ---
FBO32/...XPS/ECO --- ---
FBO32/8..XP/SS/ECO --- ---
FP14/8.. F14/T5/8.. F14T5/8..
FP21/8.. F21/T5/8.. F21T5/8..
FP28/8.. F28/T5/8.. F28T5/8..
FP35/8.. F35/T5/8.. F35T5/8..
FP24/8../HO F24/T5/8../HO F24T5/8../HO
FP39/8../HO F39/T5/8../HO F39T5/8../HO
FP54/8../HO F54/T5/8../HO F54T5/8../HO
FP80/8../HO F80/T5/8../HO F80T5/8../HO
--- F40T17/CW/IS ---
--- F96T17/… ---
HO (800mA) HO (800mA) HO (800mA)
F96T12/…/HO/COLDTEMP F96T12/…/HO/CT F96T12/…/HO-0
VHO (1500mA) 1500 or PG17 (both 1500mA) VHO (1500mA)
VHO/LT (1500mA) T10, 1500-0 (both1500mA) VHO-0 (1500mA)
Compact Fluorescent Lamps
DULUX®BIAX®PL
Medium Screw Base Lamps
CF…EL/830/MED FLE…TBX/LT
CF…EL/830/MED/1 FLE…TBX/L UNIVERSAL SLS ---
CF…EL/TWIST (15W, 20W, 23W, 27W, 30W) FLE…HLX/8/SW/CD (Spiral17W, 21W, 27W) Twister-BC-EL/DT… (15W, 20W, 23W)
CF...EL/MINITWIST (7, 11,13,19,23W) --- ---
--- --- UNIVERSAL/RH SLS.RH… (low THD)
CF28EL/3WAY/TWIST FLE29QBX/D3 (3-Way Triple) ---
--- --- DIMMABLE SLS/D 20 (Dimmable)
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
102
FLUORESCENT COMPETITIVE GUIDES (continued)
FLUORESCENT ELECTRICAL INTERCHANGEABILITY (continued)
SYLVANIA GE PHILIPS
--- --- DIMMABLE SLS/D 23 (Dimmable)
--- FLE29QBX/DV (Dimmable Triple) ---
CF15EL/R30/830/MED FLE15/TBX/L/R30 FLOOD SLS/R30 15
CF20EL/R40/830/MED FLE20TBX/L/R40 FLOOD SLS/R40 20
CF15/EL/BR30 --- Reflector Flood BC-EL/A BR30 16
CF15EL/G30/830/MED FLE15TBX/L/G29 DÉCOR GLOBE SLS/30 15
CF15EL/G30/830/MED FLG17 (magnetic) DÉCOR GLOBE SLS/30 15
CF20EL/G40/830/MED --- DÉCOR GLOBE SLS/40 15
CF15EL/G/830 (low profile Globe) FLG15/E-120 ---
CF15EL/B/830 (Bullet) FLB17 (magnetic) FLE15/6/TC19
CF15EL/ALINE FLE15/L/TC16 OUTDOOR EL/O 15
CF14EL/A19/1/BL/YELLOW FLE15/L/TC16/BUG BUG-A-WAY EL/O 15 BAW
--- FLE15/L/TC16/DAY ---
--- --- OUTDOOR EL/O 18
--- FLE20/6/T19 ---
CF9EL/C/830 (A23) --- ---
--- FLE15/A2/A23 HOUSEHOLD EL/A 16
--- FLE20/A2/A24 ---
CF30EL/CIRC/830/MED FEA30CIR ---
--- FEA382D/SW (2D w/adapter) ---
--- FEA382D/835 (2D w/adapter) ---
Pin Base Lamps
CF…DS… (2-pin) F…BX… PL-S…
CFT13WDS/EC F13BX/E ---
CF…DS/E…(4 pin) --- ---
CF…DD/… (2 pin) F…DBX… PL-C…
CF…DD/E… (4 pin) F…DBX…/4P PL-C…/4P
CF…DT… (2 pin) --- ---
CF…DT/E…(4 pin) F…TBX…/4P PL-T…/4P
CF42DT/E… (4 pin) F42QBX/SPX…/A/4P PL42W/…/4P/…
CF…DF… --- ---
--- F…TBX/I/8.../A/4P (inverted post) ---
FT18DL/8… F18BX/SPX… PL-L 18W/…
FT18DL/8…/RS F18BX/SPX…/RS ---
FT24DL/8… F27/24BX/SPX… PL-L 24W/…
FT36DL/8… F39/36BX/SPX… PL-L 36W/…
FT40DL/8…/RS F40/30BX/SPX… PL-L 40W/…/RS/IS
--- F50BX/SPX…/RS PL-L 50W/…/RS
FT55DL/8… F55BX/8... ---
--- F…2D/… ---
Induction Lamps
ICE 70/8... (ICETRON®)--- ---
ICE 100/8… (ICETRON) --- ---
ICE 150/8… (ICETRON) --- ---
--- EL23/R25/… (Genura)---
--- --- QL55W/… (QL)
--- --- QL85W/… (QL)
--- --- QL165W/…(QL)
For a more complete manufacturers' cross reference, please see that section of this catalog or visit the electronic catalog at www.sylvania.com.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
103
F
L
U
O
R
E
S
C
E
N
T
FLUORESCENT LAMPS
The bulb shape and size of a fluorescent lamp
are expressed by means of a code consisting
of the letter “T” (which designates that the
bulb is “tubular” in shape) followed by a
number that expresses the diameter in
eighths of an inch. Diameters range from T2
(14inch) to T17 (2 18inch). In nominal overall
length, linear fluorescent lamps range from 6
to 96 inches. The nominal length is measured
from back of lamp holder to back of lamp
holder. For example, the actual overall length
of the 40-watt rapid start T12 lamp with a
nominal length of 48 inches is 47 34inches.
The nominal length given for PENTRON®lin-
ear lamps is the closest familiar nominal
length. CURVALUME®U-shaped fluorescent
lamps are available as OCTRON®T8 lamps
with leg spacings of 1 58inches and 6 inches
and as rapid start T12 lamps with leg spac-
ings of 3 58inches and 6 inches. The leg spac-
ing is measured from the center of one leg to
the center of the other leg. The overall length
of the CURVALUME lamps is measured from
the face of the bases to the outside of the
glass bend. Circline lamps, which are circular
in shape, are available as T9 lamps with out-
side diameters of 6 12, 8, 12 and 16 inches as
well as PENTRON T5 lamps with outside
diameters of 8.85 and 11.77 inches.The over-
all length of DULUX®compact fluorescent
lamps is measured from the bottom of the
base to the outside edge of the glass. In many
cases, the bottom of the base is the bottom of
the center post of the base of the lamp.
T2 MINIATURE
T2 Axial Base (2/8" Diameter)
Preheat T5 Miniature Bipin (5/8" diameter
PENTRON T5 Miniature Bipin (5/8" diameter)
T8 Medium Bipin (1" diameter)
OCTRON T8 Medium Bipin (1" diameter)
Rapid Start or Instant Start operation
T12 Medium Bipin (1-1/2" diameter)
T6 Single Pin (3/4" diameter)
T8 Single Pin (1" diameter)
OCTRON T8 Single Pin (1" diameter)
T12 Single Pin (1-1/2" diameter)
U-Shaped T12
(1-1/2" diameter)
6” leg spacing
OCTRON T8 U-Shaped
with 1 5/8" leg spacing
(1" diameter)
OCTRON T8 U-Shaped
with 6" leg spacing
(1" diameter)
ICETRON®CIRCLINE 4-Pin T-9
(6-1/2", 8", 12", 16"
outside diameters)
PENTRON CIRCLINE 4-
Pin T5 (8.85" & 11.77"
outside diameters)
T14-1/2 Recessed Double Contact (1-13/16" diameter)
T12 Recessed Double Contact (1-1/2" diameter)
OCTRON T8 Recessed Double Contact (1" diameter)
DULUX S DULUX S/E DULUX D DULUX D/E DULUX T DULUX T/E
DULUX T/E/IN
DULUX
EL Triple DULUX
EL TWIST DULUX EL
GLOBE DULUX EL
REFLECTOR DULUX EL Circline (6-1/2"
& 8" outside diameters)
DULUX F
DULUX L
DULUX EL CLASSIC
(A-Shape) DULUX EL Low
Profile GLOBE
DULUX EL
BULLET
HIGH OUTPUT AND VERY HIGH OUTPUT
INSTANT START
PREHEAT, RAPID START
BR-30
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
104
F
L
U
O
R
E
S
C
E
N
T
BASES
For linear Preheat and Rapid Start Lamps, four elec-
trical contacts are required, two at each end of the
lamp. This is accomplished in the standard line of
lamps by the use of a miniature bipin base for T5
lamps and a medium bipin for T8 and T12 lamps.
The OCTRON®T8 medium bipin lamps may also be
operated as instant start lamps with the proper wiring
and ballasts. When operating OCTRON bipin lamps
with instant start ballasts, the two contacts in the
lamp holder are shorted together and connected to
the single circuit in the ballast. In Circline lamps, the
cathodes are connected to a four-pin base located
between the junction of the two ends of the lamp.
High Output (HO) and Very High Output (VHO) lamps
have recessed double contact (RDC) type bases.
Slimline Instant Start lamps require only two electri-
cal contacts, one on each lamp end and have single
pin bases.
Pin-based compact fluorescent lamps have either 2
pins or 4 pins. Each 2-pin lamp has an internal
starter and is designed for preheat, magnetic opera-
tion. The 4-pin lamps are designed for electronic bal-
last operation and are dimmable. These lamps have
no internal starter; starting the lamps is a function of
the ballast.
Medium screw base, compact fluorescent lamps have
integral ballasts.
Single Pin for
T6 Slimline Single Pin for
T12 Slimline
Medium Bipin for T12
Recessed Double Contact
for OCTRON T8 HO
OCTRON T8 & T12 Rapid Start CURVALUME
Axial T2 Subminiature
4-pin for T9 Circline
Recessed Double Contact
for T12 HO & VHO
4-pin for
PENTRON Circline
G 23-2 GX 23-2 G 24 d2 G24 d3
Single Pin for T8 Slimline
& OCTRON
G 24 q-1 G 24 q-2 G 24 q-3
GX 24 q-4
2 G 11 2 G 7 2 GX 7 2G 10
DULUX F
GX 24 d-3 GX 24 q-2
GX 24 q-1 GX 24 q-3
Medium Screw Base
or DULUX®EL
GX 24 d-2 GX 24 q-5
ICETRON®Mounting Brackets
FOR CHOKE/STARTER OPERATION
GX 23
G 23
FOR ELECTRONIC OR DIMMING OPERATION
BIPIN
SINGLE PIN
Miniature Bipin for T8
Preheat & OCTRON
Miniature Bipin for T5
Preheat & PENTRON®
DULUX®S
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
105
DULUX®S PREHEAT 2-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
with Starter in Lamp Base for Magnetic Ballast
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
5T4 4.2 107 G23 20325 CF5DS/827 CFT5W/G23/827 50 10000 2700 82 230 198 1,2,3,
4,5,6
20547 CF5DS/827/RP CFT5W/G23/827 10 10000 2700 82 230 198 1,2,3,
4,5,6
20303 CF5DS/841 CFT5W/G23/841 50 10000 4100 82 230 198 1,2,3,
4,5,6
7T4 5.3 135 G23 20327 CF7DS/827 CFT7W/G23/827 50 10000 2700 82 400 344 1,2,3,
4,5,6
20548 CF7DS/827/RP CFT7W/G23/827 10 10000 2700 82 400 344 1,2,3,
4,5,6
20310 CF7DS/835 CFTW/G23/835 50 10000 3500 82 400 344 1,2,3,
4,5,6
20304 CF7DS/841 CFT7W/G23/841 50 10000 4100 82 400 344 1,2,3,
4,5,6
20307 CF7DS/850 CFT7W/G23/850 50 10000 5000 82 400 344 1,2,3,
4,5,6
9T4 6.5 165 G23 20536 CF9DS/827/RP CFT9W/G23/827 10 10000 2700 82 580 499 1,2,3,
4,5,6
20333 CF9DS/835 CFT9W/G23/835 50 10000 3500 82 580 499 1,2,3,
4,5,6
20305 CF9DS/841 CFT9W/G23/841 50 10000 4100 82 580 499 1,2,3,
4,5,6
20308 CF9DS/850 CFT9W/G23/850 50 10000 5000 82 580 499 1,2,3,
4,5,6
20329 CF9DS/827 CFT9W/G23/827 50 10000 2700 82 800 688 1,2,3,
4,5,6
20299 DULUX S 9W/78 50 10000 BLK 1,2,4,5,7
13 T4 7.1 180 GX23 20331 CF13DS/827 CFT13W/GX23/827 50 10000 2700 82 800 688 1,2,3,
4,5,6
20374 CFT13WDS/EC/827 CFT13W/GX23/827 10 10000 2700 82 800 688 1,2,3,5,8
20549 CF13DS/827/RP CFT13W/GX23/827 10 10000 2700 82 800 688 1,2,3,
4,5,6
20283 CF13DS/830 CFT13W/GX23/830 50 10000 3000 82 800 688 1,2,3,
4,5,6
20397 CFT13WDS/EC/830 CFT13W/GX23/830 10 10000 3000 82 800 688 1,2,3,5,8
20335 CF13DS/835 CFT13W/GX23/835 50 10000 3500 82 800 688 1,2,3,
4,5,6
20368 CFT13WDS/EC/835 CFT13W/GX23/835 10 10000 3500 82 800 688 1,2,3,5,8
20306 CF13DS/841 CFT13DS/GX23/841 50 10000 4100 82 800 688 1,2,3,
4,5,6
20375 CFT13WDS/EC/841 CFT13W/GX23/841 10 10000 4100 82 800 688 1,2,3,5,8
20309 CF13DS/850 CFT13W/GX23/850 50 10000 5000 82 800 688 1,2,3,
4,5,6
F
L
U
O
R
E
S
C
E
N
T
DULUX®S/E DULUX®D
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
106
DULUX®S/E 4-PIN COMPACT FLUORESCENT LAMPS
for Dimming and Electronic Ballast
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
5T4 3.4 85 2G7 20311 CF5DS/E/827 CFT5W/2G7/827 50 10000 2700 82 230 198 1,2,3,8,9
20315 CF5DS/E/841 CFT5W/2G7/841 50 10000 4100 82 230 198 1,2,3,8,9
7T4 4.5 115 2G7 20312 CF7DS/E/827 CFT7W/2G7/827 50 10000 2700 82 400 344 1,2,3,8,9
20316 CF7DS/E/841 CFT7W/2G7/841 50 10000 4100 82 400 344 1,2,3,8,9
9T4 5.7 145 2G7 20313 CF9DS/E/827 CFT9W/2G7/827 50 10000 2700 82 580 499 1,2,3,8,9
20317 CF9DS/E/841 CFT9W/2G7/841 50 10000 4100 82 580 499 1,2,3,8,9
13 T4 6.2 157 2GX7 20314 CF13DS/E/827 CFT13W/2GX7/827 50 10000 2700 82 800 688 1,2,3,8,9
20284 CF13DS/E/830 CFT13W/2GX7/830 50 10000 3000 82 800 688 1,2,3,8,9
20318 CF13DS/E/841 CFT13W/2GX7/841 50 10000 4100 82 800 688 1,2,3,8,9
DULUX®D PREHEAT 2-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
with Starter in Lamp Base for Magnetic Ballast
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
9T4 4.3 110 G23-2 20537 CF9DD/827/RP CFQ9W/G23/827 10 10000 2700 82 525 452 1,2,3,
4,5,6
20689 CF9DD/827 CFQ9W/G23/827 50 10000 2700 82 525 452 1,2,3,
4,5,6
20783 CF9DD/830 CFQ9W/G23/830 50 10000 3000 82 525 452 1,2,3,
4,5,6
20690 CF9DD/835 CFQ9W/G23/835 50 10000 3500 82 525 452 1,2,3,
4,5,6
13 T4 4.6 118 GX23-2 20538 CF13DD/827/RP CFQ13W/GX23/827 10 10000 2700 82 780 671 1,2,3,
4,5,6
20691 CF13DD/827 CFQ13W/GX23/827 50 10000 2700 82 780 671 1,2,3,
4,5,6
20705 CF13DD/830 CFQ13W/GX23/830 50 10000 3000 82 780 671 1,2,3,
4,5,6
20692 CF13DD/835 CFQ13W/GX23/835 50 10000 3500 82 780 671 1,2,3,
4,5,6
20708 CF13DD/841 CFQ13W/GX23/841 50 10000 4100 82 780 671 1,2,3,
4,5,6
18 T4 6.0 153 G24D-2 20676 CF18DD/827 CFQ18W/G24D/827 50 10000 2700 82 1150 1075 1,2,3,
4,5,6
20709 CF18DD/830 CFQ18W/G24D/830 50 10000 3000 82 1150 1075 1,2,3,
4,5,6
20677 CF18DD/835 CFQ18W/G24D/835 50 10000 3500 82 1150 1075 1,2,3,
4,5,6
20678 CF18DD/841 CFQ18W/G24D/841 50 10000 4100 82 1150 1075 1,2,3,
4,5,6
26 T4 6.8 173 G24D-3 20679 CF26DD/827 CFQ26W/G24D/827 50 10000 2700 82 1710 1548 1,2,3,
4,5,6
20710 CF26DD/830 CFQ26W/G24D/830 50 10000 3000 82 1710 1548 1,2,3,
4,5,6
20680 CF26DD/835 CFQ26W/G24D/835 50 10000 3500 82 1710 1548 1,2,3,
4,5,6
F
L
U
O
R
E
S
C
E
N
T
DULUX®DDULUX®T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
107
DULUX®D PREHEAT 2-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
26 T4 6.8 173 G24D-3 20681 CF26DD/841 CFQ26W/G24D/841 50 10000 4100 82 1710 1548 1,2,3,
4,5,6
DULUX®D/E 4-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
for Dimming and Electronic Ballast with End-of-Lamp Life (EOL) Protection
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
13 T4 5.2 131 G24Q-1 20682 CF13DD/E/827 CFQ13W/G24Q/827 50 12000 2700 82 900 774 1,2,3,
6,8,9,10
20721 CF13DD/E/830 CFQ26W/G24Q/830 50 12000 3000 82 900 774 1,2,3,
6,8,9,10
20671 CF13DD/E/835 CFQ13W/G24Q/835 50 12000 3500 82 900 774 1,2,3,
6,8,9,10
20667 CF13DD/E/841 CFQ13W/G24Q/841 50 12000 4100 82 900 774 1,2,3,
6,8,9,10
18 T4 5.8 147 G24Q-2 20683 CF18DD/E/827 CFQ18W/G24Q/827 50 12000 2700 82 1150 1075 1,2,3,
6,8,9,10
20724 CF18DD/E/830 CFQ18W/G24Q/830 50 12000 3000 82 1150 1075 1,2,3,
6,8,9,10
20672 CF18DD/E/835 CFQ18W/G24Q/835 50 12000 3500 82 1150 1075 1,2,3,
6,8,9,10
20668 CF18DD/E/841 CFQ18W/G24Q/841 50 12000 4100 82 1150 1075 1,2,3,
6,8,9,10
26 T4 6.5 166 G24Q-3 20684 CF26DD/E/827 CFQ26W/G24D/827 50 12000 2700 82 1710 1548 1,2,3,
6,8,9,10
20722 CF26DD/E/830 CFQ26W/G24Q/830 50 12000 3000 82 1710 1548 1,2,3,
6,8,9,10
20673 CF26DD/E/835 CFQ26W/G24Q/835 50 12000 3500 82 1710 1548 1,2,3,
6,8,9,10
20669 CF26DD/E/841 CFQ26W/G24Q/841 50 12000 4100 82 1710 1548 1,2,3,
6,8,9,10
DULUX®T PREHEAT 2-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
with Starter in Lamp Base for Magnetic Ballast
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
18 T4 4.8 123 GX24D-2 20756 CF18DT/827 CFTR18W/GX24D/827 50 12000 2700 82 1200 1032 1,2,3,
4,5,6
26 T4 5.4 138 GX24D-3 20752 CF26DT/827 CFTR26W/GX24D/827 50 12000 2700 82 1800 1548 1,2,3,
4,5,6
DULUX®T/E 4-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
for Dimming and Electronic Ballast
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
13 T4 4.2 106 GX24Q-1 20891 CF13DT/E/827 CFTR13W/GX24Q/827 50 12000 2700 82 900 774 1,2,3,
6,8,9,10
20892 CF13DT/E/830 CFTR13W/GX24Q/830 50 12000 3000 82 900 774 1,2,3,
6,8,9,10
F
L
U
O
R
E
S
C
E
N
T
DULUX®T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
108
DULUX®T/E 4-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
13 T4 4.2 106 GX24Q-1 20893 CF13DT/E/835 CFTR13W/GX24Q/835 50 12000 3500 82 900 774 1,2,3,
6,8,9,10
20894 CF13DT/E/841 CFTR13W/GX24Q/841 50 12000 4100 82 900 774 1,2,3,
6,8,9,10
18 T4 4.6 116 GX24Q-2 20760 CF18DT/E/827 CFTR18W/GX24Q/827 50 12000 2700 82 1200 1032 1,2,3,
6,8,9,10
26 T4 5.2 124 GX24Q-3 20767 CF26DT/E/827 CFTR26W/GX24Q/827 50 12000 2700 82 1800 1548 1,2,3,
6,8,9,10
32 T4 5.8 147 GX24Q-3 20768 CF32DT/E/827 CFTR32W/GX24Q/827 50 12000 2700 82 2400 2064 1,2,3,
6,8,9,10,11
DULUX®T/E/IN AMALGAM, 4-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
for Dimming and Electronic Ballast for High and Low Temp Applications
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
18 T4 4.4 111 GX24Q-2 20875 CF18DT/E/IN/827 CFTR18W/GX24Q/827 50 12000 2700 82 1200 1032 1,2,3,
6,8,9,10,12
20876 CF18DT/E/IN/830 CFTR18W/GX24Q/830 50 12000 3000 82 1200 1032 1,2,3,
6,8,9,10,12
20877 CF18DT/E/IN/835 CFTR18W/GX24Q/835 50 12000 3500 82 1200 1032 1,2,3,
6,8,9,10,12
20878 CF18DT/E/IN/841 CFTR18W/GX24Q/841 50 12000 4100 82 1200 1032 1,2,3,
6,8,9,10,12
26 T4 5.0 126 GX24Q-3 20879 CF26DT/E/IN/827 CFTR26W/GX24Q/827 50 12000 2700 82 1800 1548 1,2,3,
6,8,9,10,12
20880 CF26DT/E/IN/830 CFTR26W/GX24Q/830 50 12000 3000 82 1800 1548 1,2,3,
6,8,9,10,12
20881 CF26DT/E/IN/835 CFTR26W/GX24Q/835 50 12000 3500 82 1800 1548 1,2,3,
6,8,9,10,12
20882 CF26DT/E/IN/841 CFTR26W/GX24Q/841 50 12000 4100 82 1800 1548 1,2,3,
6,8,9,10,12
32 T4 5.6 142 GX24Q-3 20883 CF32DT/E/IN/827 CFTR32W/GX24Q/827 50 12000 2700 82 2400 2064 1,2,3,
6,8,9,10,11,12
20884 CF32DT/E/IN/830 CFTR32W/GX24Q/830 50 12000 3000 82 2400 2064 1,2,3,
6,8,9,10,11,12
20885 CF32DT/E/IN/835 CFTR32W/GX24Q/835 50 12000 3500 82 2400 2064 1,2,3,
6,8,9,10,11,12
20886 CF32DT/E/IN/841 CFTR32W/GX24Q/841 50 12000 4100 82 2400 2064 1,2,3,
6,8,9,10,11,12
42 T4 6.5 163 GX24Q-4 20887 CF42DT/E/IN/827 CFTR42W/GX24Q/827 50 12000 2700 82 3200 2752 1,2,3,
6,8,9,10,11,12
20888 CF42DT/E/IN/830 CFTR42W/GX24Q/830 50 12000 3000 82 3200 2752 1,2,3,
6,8,9,10,11,12
20871 CF42DT/E/IN/835 CFTR/42W/GX24Q/835 50 12000 3500 82 3200 2752 1,2,3,
6,8,9,10,11,12
20890 CF42DT/E/IN/841 CFTR42W/GX24Q/841 50 12000 4100 82 3200 2752 1,2,3,
6,8,9,10,11,12
57 T4 7.76 197 GX24Q-5 20895 CF57DT/E/IN/827 CFTR57W/GX24Q/827 50 12000 2700 82 4300 3698 1,2,3,
6,8,9,10,11,12
F
L
U
O
R
E
S
C
E
N
T
DULUX®TDULUX®L
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
109
DULUX®T/E/IN AMALGAM, 4-PIN ECOLOGIC®COMPACT FLUORESCENT LAMPS
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
57 T4 7.76 197 GX24Q-5 20896 CF57DT/E/IN/830 CFTR57W/GX24Q/830 50 12000 3000 82 4300 3698 1,2,3,
6,8,9,10,11,12
20897 CF57DT/E/IN/835 CFTR57W/GX24Q/835 50 12000 3500 82 4300 3698 1,2,3,
6,8,9,10,11,12
20899 CF57DT/E/IN/841 CFTR57W/GX24Q/841 50 12000 4100 82 4300 3698 1,2,3,
6,8,9,10,11,12
70 T4 9.25 235 GX24Q-6 20794 CF70DT/E/IN/827 CFTR70W/GX24Q/827 50 12000 2700 82 5200 4472 1,2,3,
6,8,9,10,11,12
20795 CF70DT/E/IN/830 CFTR70W/GX24Q/830 50 12000 3000 82 5200 4472 1,2,3,
6,8,9,10,11,12
20796 CF70DT/E/IN/835 CFTR70W/GX24Q/835 50 12000 3500 82 5200 4472 1,2,3,
6,8,9,10,11,12
20797 CF70DT/E/IN/841 CFTR70W/GX24Q/841 50 12000 4100 82 5200 4472 1,2,3,
6,8,9,10,11,12
DULUX®L HIGH LUMEN COMPACT FLUORESCENT LAMPS
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
18 T5 9.0 229 2G11 20587 FT18DL/830 FT18W/2G11/830 10 12000 3000 82 1250 1075 1,2,3,8,9
10.5 267 2G11 20595 FT18DL/830/RS FT18W/2G11/RS/830 10 20000 3000 82 1250 1075 1,2,3,8,9
9.0 229 2G11 20588 FT18DL/835 FT18W/2G11/835 10 12000 3500 82 1250 1075 1,2,3,8,9
10.5 267 2G11 20594 FT18DL/835/RS FT18W/2G11/RS/835 10 20000 3500 82 1250 1075 1,2,3,8,9
9.0 229 2G11 20589 FT18DL/841 FT18W/2G11/841 10 12000 4100 82 1250 1075 1,2,3,8,9
10.5 267 2G11 20593 FT18DL/841/RS FT18W/2G11/RS/841 10 20000 4100 82 1250 1075 1,2,3,8,9
24 T5 12.9 326 2G11 20597 FT24DL/830 FT24W/2G11/830 10 12000 3000 82 1800 1548 1,2,3,8,9,
13
20580 FT24DL/835 FT24W/2G11/835 10 12000 3500 82 1800 1548 1,2,3,8,9,
13
20596 FT24DL/841 FT24W/2G11/841 10 12000 4100 82 1800 1548 1,2,3,8,9,
13
36 T5 16.6 422 2G11 20581 FT36DL/830 FT36W/2G11/830 10 12000 3000 82 2900 2494 1,2,3,8,9,
13
20582 FT36DL/835 FT36W/2G11/835 10 12000 3500 82 2900 2494 1,2,3,8,9,
13
20583 FT36DL/841 FT36W/2G11/841 10 12000 4100 82 2900 2494 1,2,3,8,9,
13
40 T5 22.6 573 2G11 20584 FT40DL/830/RS FT40W/2G11/RS/830 10 20000 3000 82 3150 2709 1,2,3,8,9
20585 FT40DL/835/RS FT40W/2G11/RS/835 10 20000 3500 82 3150 2709 1,2,3,8,9
20586 FT40DL/841/RS FT40W/2G11/RS/841 10 20000 4100 82 3150 2709 1,2,3,8,9
20576 FT40DL/850/RS FT40W/2G11/RS/850 10 20000 5000 82 3150 2709 1,2,3,8,9
55 T5 21.1 535 2G11 20590 FT55DL/830 FT55W/2G11/830 10 12000 3000 82 4800 4128 1,2,3,8,9,
14
20591 FT55DL/835 FT55W/2G11/835 10 12000 3500 82 4800 4128 1,2,3,8,9,
14
20592 FT55DL/841 FT55W/2G11/841 10 12000 4100 82 4800 4128 1,2,3,8,9,
14
80 T5 22.6 573 2G11 20572 FT80DL/830 F180W/2G11/830 10 12000 3000 82 6000 5160 1,2,3,8,9,
14
F
L
U
O
R
E
S
C
E
N
T
DULUX®LDULUX®FDULUX®EL Triple DULUX®EL Twist
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
110
DULUX®L HIGH LUMEN COMPACT FLUORESCENT LAMPS
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
80 T5 22.6 573 2G11 20622 FT80DL/835 FT80W/2G11/835 10 12000 3500 82 6000 5160 1,2,3,8,9,
14
20624 FT80DL/841 FT40W/2G11/841 10 12000 4100 82 6000 5160 1,2,3,8,9,
14
DULUX®F FLAT COMPACT FLUORESCENT LAMPS
42 Avg Avg Approx Lumens
|
Nominal MOL Product NEMA Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (mm) Base Number Ordering Abbreviation Generic Designation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
18 T5 4.8 122 2G10 20551 CF18DF/830 CFM18W/2G10/830 10 10000 3000 82 1100 946 1,2,3,8,9,
15
20552 CF18DF/841 CFM18W/2G10/841 10 10000 4100 82 1100 946 1,2,3,8,9,
15
24 T5 6.7 171 2G10 20553 CF24DF/830 CFM24W/2G10/830 10 10000 3000 82 1700 1462 1,2,3,8,9,
15
20558 CF24DF/841 CFM24W/2G10/841 10 10000 4100 82 1700 1462 1,2,3,8,9,
15
36 T5 8.5 217 2G10 20559 CF36DF/830 CFM36W/2G10/830 10 10000 3000 82 2800 2408 1,2,3,8,9,
15
20560 CF36DF/841 CFM36W/2G10/841 10 10000 4100 82 2800 2408 1,2,3,8,9,
15
DULUX®EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Triple Tube Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 T4 5.7 Med 29307 CF15EL/830/MED/1 120 6 10000 3000 82 850 731 1,2,
3,16,17,18
20 T4 6.42 Med 29308 CF20EL/830/MED/1 120 6 10000 3000 82 1200 1032 1,2,
3,16,17,18
23 T4 6.93 Med 29310 CF23EL/830/MED/1 120 6 10000 3000 82 1450 1247 1,2,
3,16,17,18
Mini Twist Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
7MINITWIST 4.4 Med 29451 CF7EL/MINITWIST/2700K 120 6 8000 2700 82 375 323 1,2,
3,16,17,18
29379 CF7EL/MINITWIST/1 120 6 8000 3000 82 375 323 1,2,
3,16,17,18
29371 CF7EL/MINITWIST/BL/1 120 6 8000 3000 82 375 323 1,2,
3,16,17,18
11 MINITWIST 4.5 Med 29378 CF11EL/MINITWIST/1 120 6 8000 3000 82 600 516 1,2,
3,16,17,18
29364 CF11EL/MINITWIST/BL/1 120 6 8000 3000 82 600 516 1,2,
3,16,17,18
13 MINITWIST 4.5 Med 29409 CF13EL/MINITWIST/2700K 120 6 8000 2700 82 800 688 1,2,
3,16,17,18
29376 CF13EL/MINITWIST/1 120 6 8000 3000 82 800 688 1,2,
3,16,17,18
F
L
U
O
R
E
S
C
E
N
T
DULUX®EL Twist
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
111
DULUX®EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Mini Twist Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
13 MINITWIST 4.5 Med 29116 CF13EL/MINITWIST/BL/1 120 6 8000 3000 82 800 688 1,2,
3,16,17,18
29169 CF13EL/MINITWIST/DAY/BL/1 120 6 8000 3500 82 800 688 1,2,
3,16,17,18
19 MINITWIST 5.2 Med 29410 CF19EL/MINITWIST/2700K 120 6 8000 2700 82 1200 1032 1,2,
3,16,17,18
29396 CF19EL/MINITWIST 120 6 8000 3000 82 1200 1032 1,2,
3,16,17,18
29347 CF19EL/MINITWIST/BL/1 120 5 8000 3000 82 1200 1032 1,2,
3,16,17,18
29367 CF19EL/MINITWIST/DAY/BL/1 120 5 8000 3500 82 1200 1032 1,2,
3,16,17,18
23 MINITWIST 5.75 Med 29411 CF23EL/MINITWIST/2700K 120 6 8000 2700 82 1600 1376 1,2,
3,16,17,18
29397 CF23EL/MINITWIST 120 6 8000 3000 82 1600 1376 1,2,
3,16,17,18
29394 CF23EL/MINITWIST/BL/1 120 5 8000 3000 82 1600 1376 1,2,
3,16,17,18
29417 CF23EL/MINITWIST/DAY/BL/1120 5 8000 3500 82 1600 1376 1,2,
3,16,17,18
Twist Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 TWIST 5.13 Med 29286 CF15EL/TWIST 120 6 10000 3000 82 850 731 1,2,
3,16,17,18
29289 CF15EL/TWIST/BL/1 120 6 10000 3000 82 850 731 1,2,
3,16,17,18
20 TWIST 5.5 Med 29287 CF20EL/TWIST 120 6 10000 3000 82 1200 1032 1,2,
3,16,17,18
29290 CF20EL/TWIST/BL/1 120 6 10000 3000 82 1200 1032 1,2,
3,16,17,18
23 TWIST 5.88 Med 29288 CF23EL/TWIST 120 6 10000 3000 82 1450 1247 1,2,
3,16,17,18
29291 CF23EL/TWIST/BL/1 120 6 10000 3000 82 1450 1247 1,2,
3,16,17,18
27 TWIST 6.1 Med 29412 CF27EL/TWIST/2700K 120 6 10000 2700 82 1750 1505 1,2,
3,16,17,18
29390 CF27EL/TWIST 120 6 10000 3000 82 1750 1505 1,2,
3,16,17,18
29391 CF27EL/TWIST/1/BL 120 6 10000 3000 82 1750 1505 1,2,
3,16,17,18
29370 CF27EL/TWIST/DAY/1/BL 120 6 10000 3500 82 1750 1505 1,2,
3,16,17,18
29353 CF27EL/TWIST/5000K 120 6 10000 5000 82 1750 1505 1,2,
3,16,17,18
30 TWIST 5.13 Med 29395 CF30EL/TWIST 120 6 6000 3000 82 2000 1720 1,2,
3,16,17,18
F
L
U
O
R
E
S
C
E
N
T
DULUX®EL Twist DULUX®EL Classic DULUX®EL Globe DULUX®EL Reflector
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
112
DULUX®EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Twist Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
30 TWIST 5.13 Med 29392 CF30EL/TWIST/1/BL 120 5 6000 3000 82 2000 1720 1,2,
3,16,17,18
12 TWIST 5.75 3Contact Med 29351 CF28EL/3WAY/TWIST/1 120 6 6000 3000 82 600 516 1,2,
19 1100 946 3,16,17,18
28 1600 1376
29349 CF28EL/3WAY/TWIST/1/BL 120 5 6000 3000 82 600 516 1,2,
1100 946 3,16,17,18
1600 1376
Classic (A-Shape) Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
14 A19 4.75 Med 29468 CF14EL/A19 120 5 6000 3000 82 800 688 1,2,
3,16,17,18
29345 CF14EL/A19/1/BL 120 5 6000 3000 82 800 688 1,2,
3,16,17,18
29346 CF14EL/A19/1/BL/YELLOW 120 5 6000 YLW 82 475 409 1,2,
3,16,17,18
Decorative Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
4Flame 4.25 Candelabra 29135 CF4EL/DECO/CANDELABRA 120 6 6000 3000 82 160 138 1,2,
3,16,17,18
29121 CF4EL/DECO/CANDELABRA/1/BL120 6 6000 3000 82 160 138 1,2,
3,16,17,18
7Flame 5 Med 29167 CF7EL/DECO/MEDIUM/1/BL 120 6 6000 3000 82 280 241 1,2,
3,16,17,18
Globe Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
11 G25 4.6 Med 29414 CF11EL/G25/2700K 120 6 6000 2700 82 450 387 1,2,
3,16,17,18
29344 CF11EL/G25/1/BL 120 5 6000 3000 82 450 387 1,2,
3,16,17,18
29368 CF11EL/G25/DAY/1/BL 120 5 6000 3500 82 450 387 1,2,
3,16,17,18
15 G30 5.5 Med 29195 CF15EL/G/830/MED 120 6 6000 3000 82 700 602 1,2,
3,16,17,18
29278 CF15EL/G/830/MED/1/BL 120 5 6000 3000 82 700 602 1,2,
3,16,17,18
Reflector Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 BR30 5.6 Med 29413 CF15EL/BR30/2700K 120 6 6000 2700 82 560 482 1,2,
3,16,17,18
F
L
U
O
R
E
S
C
E
N
T
DULUX®EL Reflector Circline
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
113
DULUX®EL SELF-BALLASTED COMPACT FLUORESCENT LAMPS
Reflector Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 BR30 5.6 Med 29352 CF15EL/BR30/FROST 120 6 6000 3000 82 560 482 1,2,
3,16,17,18
29331 CF15EL/BR30/FROST/1/BL 120 5 6000 3000 82 560 482 1,2,
3,16,17,18
29366 CF15EL/BR30/DAY/BL/1 120 5 6000 3500 82 560 482 1,2,
3,16,17,18
20 BR40 6.5 Med 29399 CF20EL/BR40 120 6 8000 2700 82 900 774 1,2,
3,16,17,18
Low Profile Bullet and Circline Electronic Compact Fluorescent Lamps
44 Avg Avg Approx Lumens
|
Nominal MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) Base Number Ordering Abbreviation Voltage Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 T20 5.5 Med 29195 CF15EL/B/830/MED 120 6 6000 3000 82 700 602 1,2,
3,16,17,18
29278 CF15EL/B/830/MED/1/BL 120 6 6000 3000 82 700 602 1,2,
3,16,17,18
30 T9 2.8 Med 29294 CF30EL/CIRC/830/MED 120 5 10000 3000 82 1800 1548 1,2,
3,16,17,18
F
L
U
O
R
E
S
C
E
N
T
T8 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
114
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®lamps are T8 fluorescent lamps designed to be operated on dedicated magnetic rapid start or electronic instant start, rapid start or programmed rapid
start (also known as programmed start) ballasts. OCTRON lamps may be operated on electronic instant start ballasts with ballast factors ranging from .71 to
1.20 at the nominal ballast input voltage. For details on various lamp/ballast system combinations, please refer to the Systems Performance Guide in the “SYL-
VANIA QUICKTRONIC®Ballast Technology & Specification Guide”.
OCTRON®700 and 700 XP™ Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
14 T8 18 17.91 Med Bipin 21665 FO13/730/ECO 30 20000 3000 75 830 745 1,2,6,
8,20,21
21666 FO13/735/ECO 30 20000 3500 75 830 745 1,2,6,
8,20,21
21667 FO13/741/ECO 30 20000 4100 75 830 745 1,2,6,
8,20,21
17 T8 24 23.78 Med Bipin 21918 FO17/730/ECO 30 20000 3000 75 1300 1170 1,2,6,
8,20,21
21636 FO17/730/XP/ECO 30 24000 3000 78 1325 1255 1,2,6,
8,21,22,23
21769 FO17/735/ECO 30 20000 3500 75 1300 1170 1,2,6,
8,20,21
21699 FO17/735/XP/ECO 30 24000 3500 78 1325 1255 1,2,6,
8,21,22,23
21770 FO17/741/ECO 30 20000 4100 75 1300 1170 1,2,6,
8,20,21
21637 FO17/741/XP/ECO 30 24000 4100 78 1325 1255 1,2,6,
8,21,22,23
25 T8 36 35.78 Med Bipin 21937 FO25/730/ECO 30 20000 3000 75 1950 1755 1,2,6,
8,20,21
21638 FO25/730/XP/ECO 30 24000 3000 78 2050 1945 1,2,6,
8,21,22,23
21941 FO25/735/ECO 30 20000 3500 75 1950 1755 1,2,6,
8,20,21
21698 FO25/735/XP/ECO 30 24000 3500 78 2050 1945 1,2,6,
8,21,22,23
21942 FO25/741/ECO 30 20000 4100 75 1950 1755 1,2,6,
8,20,21
21639 FO25/741/XP/ECO 30 24000 4100 78 2050 1945 1,2,6,
8,21,22,23
21700 FO25/765 30 20000 6500 75 2000 1800 1,2,8,20,21
32 T8 48 47.78 Med Bipin 21961 FO32/GOLD 10 20000 1700 1530 1,2,8,20,21,24
21234 FO32/AQUATIC/XP/ECO 30 24000 10000 52 1250 1,2,6,8,20,
21,22
21997 FO32/730/ECO 30 20000 3000 75 2800 2520 1,2,
6,8,20,21
22006 FO32/730/ECO/PALLET 1968 20000 3000 75 2800 2520 1,2,
6,8,20,21
21711 FO32/730/XP/ECO 30 24000 3000 78 2850 2705 1,2,
6,8,21,22,23
21902 FO32/735/CVP 12 20000 3500 75 2800 2520 1,2,8,
20,21
21998 FO32/735/ECO 30 20000 3500 75 2800 2520 1,2,
6,8,20,21
21945 FO32/735/ECO/PALLET 1968 20000 3500 75 2800 2520 1,2,
6,8,20,21
F
L
U
O
R
E
S
C
E
N
T
T8 Med Bipin T8 Single Pin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
115
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®700 and 700 XP™ Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
32 T8 48 47.78 Med Bipin 21678 FO32/735/SL 30 20000 3500 75 2745 2470 1,2,20,
21,25,26
22044 FO32/735/XP/ECO 30 24000 3500 78 2850 2705 1,2,6,
8,21,22,23
21981 FO32/741/CVP 12 20000 4100 75 2800 2520 1,2,8,
20,21
21999 FO32/741/ECO 30 20000 4100 75 2800 2520 1,2,
6,8,20,21
22181 FO32/741/ECO/CVP 12 20000 4100 75 2800 2520 1,2,6,
8,20,21
22008 FO32/741/ECO/PALLET 1968 20000 4100 75 2800 2520 1,2,
6,8,20,21
21712 FO32/741/XP/ECO 30 24000 4100 78 2850 2705 1,2,
6,8,21,22,23
22141 FO32/750/ECO 30 20000 5000 75 2650 2385 1,2,
6,8,20,21
22175 FO32/765/ECO 30 20000 6500 75 2700 2430 1,2,
6,8,20,21
40 T8 60 59.61 Med Bipin 22102 FO40/730/ECO 30 20000 3000 75 3500 3150 1,2,6,
8,20,21
22103 FO40/735/ECO 30 20000 3500 75 3500 3150 1,2,6,
8,20,21
22104 FO40/741/ECO 30 20000 4100 75 3500 3150 1,2,6,
8,20,21
59 T8 96 94 Single Pin 22030 FO96/730/ECO 24 15000 3000 75 5700 5130 1,2,
6,8,27
21737 FO96/735/ECO 24 15000 3500 75 5700 5130 1,2,
6,8,27
21736 FO96/741/ECO 24 15000 4100 75 5700 5130 1,2,
6,8,27
86 T8 96 93.91 Recessed DC 22041 FO96/735/HO 24 18000 3500 75 8000 7200 1,2,8
22042 FO96/741/HO 24 18000 4100 75 8000 7200 1,2,8
OCTRON®800, 800 XP™ and 800 XPS®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
17 T8 24 23.78 Med Bipin 22135 FO17/830/ECO 30 20000 3000 82 1350 1240 1,2,6,
8,20,21
21785 FO17/830/XP/ECO 30 24000 3000 85 1375 1305 1,2,6,
8,21,22,23
22150 FO17/830/XPS/ECO 30 30000 3000 85 1400 1340 1,2,6,
8,21,28,31
22136 FO17/835/ECO 30 20000 3500 82 1350 1240 1,2,6,
8,20,21
21778 FO17/835/XP/ECO 30 24000 3500 85 1375 1305 1,2,6,
8,21,22,23
22151 FO17/835/XPS/ECO 30 30000 3500 85 1400 1340 1,2,6,
8,21,28,31
F
L
U
O
R
E
S
C
E
N
T
T8 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
116
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®lamps are T8 fluorescent lamps designed to be operated on dedicated magnetic rapid start or electronic instant start, rapid start or programmed rapid
start (also known as programmed start) ballasts. OCTRON lamps may be operated on electronic instant start ballasts with ballast factors ranging from .71 to
1.20 at the nominal ballast input voltage. For details on various lamp/ballast system combinations, please refer to the Systems Performance Guide in the “SYL-
VANIA QUICKTRONIC®Ballast Technology & Specification Guide”.
OCTRON®800, 800 XP™ and 800 XPS®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
17 T8 24 23.78 Med Bipin 22137 FO17/841/ECO 30 20000 4100 82 1350 1240 1,2,6,
8,20,21
21907 FO17/841/XP/ECO 30 24000 4100 85 1375 1305 1,2,6,
8,21,22,23
22152 FO17/841/XPS/ECO 30 30000 4100 85 1400 1340 1,2,6,
8,21,28,31
25 T8 36 35.78 Med Bipin 22138 FO25/830/ECO 30 20000 3000 82 2150 1975 1,2,6,
8,20,21
21910 FO25/830/XP/ECO 30 24000 3000 85 2175 2065 1,2,6,
8,21,22,23
22153 FO25/830/XPS/ECO 30 30000 3000 85 2200 2090 1,2,6,
8,21,28,31
22139 FO25/835/ECO 30 20000 3500 82 2150 1975 1,2,6,
8,20,21
21776 FO25/835/XP/ECO 30 24000 3500 85 2175 2065 1,2,6,
8,21,22,23
22154 FO25/835/XPS/ECO 30 30000 3500 85 2200 2090 1,2,6,
8,21,28,31
22140 FO25/841/ECO 30 20000 4100 82 2150 1975 1,2,6,
8,20,21
21774 FO25/841/XP/ECO 30 24000 4100 85 2175 2065 1,2,6,
8,21,22,23
22155 FO25/841/XPS/ECO 30 30000 4100 85 2200 2090 1,2,6,
8,21,28,31
28 T8 48 47.78 Med Bipin 22177 FO28/830/XP/SS/ECO 30 18000 3000 82 2725 2560 1,2,6,
22,23,29,30
22178 FO28/835/XP/SS/ECO 30 18000 3500 82 2725 2560 1,2,6,
22,23,29,30
22179 FO28/841/XP/SS/ECO 30 18000 4100 82 2725 2560 1,2,6,
22,23,29,30
30 T8 48 47.78 Med Bipin 22063 FO30/830/XP/SS/ECO 30 18000 3000 82 2850 2680 1,2,6,
22,23,29,30
22060 FO30/835/XP/SS/ECO 30 18000 3500 82 2850 2680 1,2,6,
22,23,29,30
22062 FO30/841/XP/SS/ECO 30 18000 4100 82 2850 2680 1,2,6,
22,23,29,30
32 T8 48 47.78 Med Bipin 22039 FO32/827/XP/ECO 30 24000 2700 84 3000 2850 1,2,6,
8,21,22,23
21777 FO32/830/ECO 30 20000 3000 82 2950 2710 1,2,
6,8,20,21
21759 FO32/830/XP/ECO 30 24000 3000 85 3000 2850 1,2,6,
8,21,22,23
21680 FO32/830/XPS/ECO 30 30000 3000 85 3100 2945 1,2,6,
8,14,21,28,31
21779 FO32/835/ECO 30 20000 3500 82 2950 2710 1,2,
6,8,20,21
F
L
U
O
R
E
S
C
E
N
T
T8 Med Bipin T8 Single Pin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
117
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®800, 800 XP™ and 800 XPS®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
32 T8 48 47.78 Med Bipin 21763 FO32/835/XP/ECO 30 24000 3500 85 3000 2850 1,2,6,
8,21,22,23
21697 FO32/835/XPS/ECO 30 30000 3500 85 3100 2945 1,2,6,
8,14,21,28,31
21676 FO32835PLT 1776/CS 1/SKU 1776 20000 3500 82 2950 2714 1,2,8,
20,21
21781 FO32/841/ECO 30 20000 4100 82 2950 2710 1,2,
6,8,20,21
21767 FO32/841/XP/ECO 30 24000 4100 85 3000 2850 1,2,6,
8,21,22,23
21681 FO32/841/XPS/ECO 30 30000 4100 85 3150 2990 1,2,6,
8,14,21,28,31
22143 FO32/850/ECO 30 20000 5000 80 2800 2576 1,2,6,
8,20,21
22026 FO32/850/XP/ECO 30 24000 5000 85 3000 2850 1,2,6,
8,21,22,23
40 T8 60 59.61 Med Bipin 22144 FO40/830/ECO 30 20000 3000 82 3650 3473 1,2,6,
8,20,21
21912 FO40/830/XP/ECO 30 24000 3000 85 3750 3560 1,2,6,
8,21,22,23
22145 FO40/835/ECO 30 20000 3500 82 3650 3473 1,2,6,
8,20,21
21911 FO40/835/XP/ECO 30 24000 3500 85 3750 3560 1,2,6,
8,21,22,23
22146 FO40/841/ECO 30 20000 4100 82 3650 3473 1,2,6,
8,20,21
21916 FO40/841/XP/ECO 30 24000 4100 85 3750 3560 1,2,6,
8,21,22,23
55 T8 96 94 Single Pin 22099 FO96/830/XP/SS/ECO 24 18000 3000 82 5700 5415 1,2,6,
34,35
22100 FO96/835/XP/SS/ECO 24 18000 3500 82 5700 5415 1,2,6,
34,35
22101 FO96/841/XP/SS/ECO 24 18000 4100 82 5700 5415 1,2,6,
34,35
59 T8 96 94 Single Pin 22147 FO96/830/ECO 24 15000 3000 82 5900 5428 1,2,
6,8,36
22036 FO96/830/XP/ECO 24 18000 3000 85 6100 5795 1,2,6,
8,14,22,35
22148 FO96/835/ECO 24 15000 3500 82 5900 5428 1,2,6,
8,36
21740 FO96/835/XP 24 18000 3500 85 6100 5795 1,2,8,14,
22,35
22034 FO96/835/XP/ECO 24 18000 3500 85 6100 5795 1,2,6,
8,14,22,35
22149 FO96/841/ECO 24 15000 4100 82 5900 5428 1,2,
6,8,36
22025 FO96/841/XP 24 18000 4100 85 6100 5795 1,2,8,14,
22,35
22032 FO96/841/XP/ECO 24 18000 4100 85 6100 5795 1,2,6,
8,14,22,35
F
L
U
O
R
E
S
C
E
N
T
T8 Single Pin T8 Med Bipin T8 U-Shaped (leg spacing of 1-5/8" )
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
118
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®800, 800 XP™ and 800 XPS®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
59 T8 96 94 Single Pin 22173 FO96/850/ECO 24 15000 5000 80 5900 5428 1,2,
6,8,36
22174 FO96/850/XP/ECO 24 18000 5000 85 5900 5605 1,2,6,
8,22,27
86 T8 96 93.91 Recessed DC 22037 FO96/835/HO 24 18000 3500 84 8200 7380 1,2,8
22040 FO96/841/HO 24 18000 4100 80 8200 7380 1,2,8
OCTRON®5000K And 6500K for Displays, Signage and Backlighting
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
14 T8 18 17.91 Med Bipin 21731 FO13/865/XP/ECO 30 24000 6500 85 850 805 1,2,6,
8,21,22,23
20 19.78 Med Bipin 21868 FO14/950/20in 30 20000 5000 90 750 638 1,2,8,20,21
15 T8 20 19.78 Med Bipin 21716 FO14/865/XP/ECO 30 24000 6500 85 1000 950 1,2,6,
8,21,22,23
16 T8 10.5 10.60 Med Bipin 21726 FBO16/865XP 15 24000 6500 85 1125 1069 1,2,8,21,22,
23,37,38
17 T8 24 23.78 Med Bipin 21871 FO17/950/24in 30 20000 5000 90 800 680 1,2,8,20,21
21718 FO17/865/XP/ECO 30 24000 6500 85 1250 1188 1,2,6,
8,21,22,23
21 T8 30 29.78 Med Bipin 21869 FO21/950/30in 30 20000 5000 90 1000 850 1,2,8,20,21
21730 FO21/865/XP/ECO 30 24000 6500 85 1600 1520 1,2,6,
8,21,22,23
25 T8 36 35.78 Med Bipin 21872 FO25/950/36in 30 20000 5000 90 1250 1063 1,2,8,20,21
21719 FO25/865/XP/ECO 30 24000 6500 85 2000 1900 1,2,6,
8,21,22,23
28 T8 40 39.78 Med Bipin 21870 FO28/950/40in 30 20000 5000 90 1800 1530 1,2,8,20,21
21727 FO28/865/XP/ECO 30 24000 6500 85 2250 2138 1,2,6,
8,21,22,23
32 T8 48 47.78 Med Bipin 21880 FO32/950/48in 30 20000 5000 90 1800 1530 1,2,8,20,21
21720 FO32/865/XP/ECO 30 24000 6500 85 2850 2708 1,2,6,
8,21,22,23
40 T8 60 59.61 Med Bipin 21873 FO40/950/60in 30 20000 5000 90 2200 1870 1,2,8,20,21
21721 FO40/865/XP/ECO 30 24000 6500 85 3650 3468 1,2,6,
8,21,22,23
OCTRON®CURVALUME®U-Shaped Lamps, 1 5/8" Leg Spacing
The OCTRON®CURVALUME®lamps are made to the same color standards and may be used in combination with other SYLVANIA OCTRON lamps to meet the
needs of lighting installations where OCTRON T8 systems are used. Since Curvalume and linear OCTRON lamps of the same/similar wattages operate on the
ballasts, the types of ballasts used in an installation can be minimized. When OCTRON FBO31 lamps are used in 2x2 luminaires, the 2x2 luminaires can deliver
light levels similar to 2x4 luminaires with the same number of linear OCTRON lamps. The nominal length of the CURVALUME lamp is measured from base face
to the outside of the glass bend.
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
16 T8 10.5 10.60 Med Bipin 21834 FBO16/830 15 20000 3000 82 1125 1035 1,2,8,20,21,
37,38
21835 FBO16/835 15 20000 3500 82 1125 1035 1,2,8,20,21,
37,38
F
L
U
O
R
E
S
C
E
N
T
T8 U-Shaped (leg spacing of 1-5/8" ) T8 U-Shaped (leg spacing of 6")
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
119
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®CURVALUME®U-Shaped Lamps, 1 5/8" Leg Spacing
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
16 T8 10.5 10.60 Med Bipin 21836 FBO16/841 15 20000 4100 82 1125 1035 1,2,8,20,21,
37,38
21726 FBO16/865XP 15 24000 6500 85 1125 1069 1,2,8,21,22,
23,37,38
24 T8 16.5 16.6 Med Bipin 21874 FBO24/830 15 20000 3000 82 1925 1771 1,2,8,20,21,
37,38
21875 FBO24/835 15 20000 3500 82 1925 1771 1,2,8,20,21,
37,38
21876 FBO24/841 15 20000 4100 82 1925 1771 1,2,8,20,21,
37,38
31 T8 22.5 22.6 Med Bipin 21877 FBO31/830 15 20000 3000 82 2725 2507 1,2,8,
20,21,37,38
21693 FBO31/830/XP/ECO 15 24000 3000 85 2775 2636 1,2,6,
8,21,22,23,37,38
21878 FBO31/835 15 20000 3500 82 2725 2507 1,2,8,
20,21,37,38
21695 FBO31/835/XP/ECO 15 24000 3500 85 2775 2636 1,2,6,
8,21,22,23,37,38
21879 FBO31/841 15 20000 3500 82 2725 2507 1,2,8,
20,21,37,38
21696 FBO31/841/XP/ECO 15 24000 4100 85 2775 2636 1,2,6,
8,21,22,23,37,38
21926 FBO31/841XP 15 24000 4100 85 2775 2636 1,2,8,21,22,
23,37,38
21819 FBO31/750 15 20000 5000 75 2600 2340 1,2,8,
20,21,37,38
OCTRON®CURVALUME®U-Shaped Lamps, 6" Leg Spacing
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
30 T8 22.5 22.6 Med Bipin 22170 FBO30/830XP/6/SS/ECO 16 18000 3000 82 2800 2632 1,2,6,
22,23,29,30,37
22171 FBO30/835XP/6/SS/ECO 16 18000 3500 82 2800 2632 1,2,6,
22,23,29,30,37
22172 FBO30/841XP/6/SS/ECO 16 18000 4100 82 2800 2632 1,2,6,
22,23,29,30,37
32 T8 22.5 22.6 Med Bipin 22046 FBO32/730/6/ECO 16 20000 3000 75 2750 2475 1,2,
6,8,20,21,37
21970 FBO32/830/6 16 20000 3000 82 2850 2622 1,2,8,
20,21,37
21663 FBO32/830/6/ECO 16 20000 3000 82 2850 2622 1,2,6,
8,20,21,37
22054 FBO32/830XP/6/ECO 16 24000 3000 85 2900 2755 1,2,6,
8,21,22,23,37
22094 FBO32/830XPS/6/ECO 16 24000 3000 85 3000 2850 1,2,6,
8,21,37,39,40
22051 FBO32/735/6/ECO 16 20000 3500 75 2750 2475 1,2,
6,8,20,21,37
F
L
U
O
R
E
S
C
E
N
T
T8 U-Shaped (leg spacing of 6") T5 Mini Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
120
OCTRON®AND OCTRON®CURVALUME®FLUORESCENT LAMPS
OCTRON®CURVALUME®U-Shaped Lamps, 6" Leg Spacing
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
32 T8 22.5 22.6 Med Bipin 21670 FBO32/835/6/ECO 16 20000 3500 82 2850 2622 1,2,6,
8,20,21,37
21984 FBO32/835XP/6 16 24000 3500 85 2900 2755 1,2,8,21,22,
23,37
22055 FBO32/835XP/6/ECO 16 24000 3500 85 2900 2755 1,2,6,
8,21,22,23,37
22095 FBO32/835XPS/6/ECO 16 24000 3500 85 3000 2850 1,2,6,
8,21,37,39,40
22052 FBO32/741/6/ECO 16 20000 4100 75 2750 2475 1,2,
6,8,20,21,37
21671 FBO32/841/6/ECO 16 20000 4100 82 2850 2622 1,2,6,
8,20,21,37
22057 FBO32/841XP/6/ECO 16 24000 4100 85 2900 2755 1,2,6,
8,21,22,23,37
22096 FBO32/841XPS/6/ECO 16 24000 4100 85 3000 2850 1,2,6,
8,21,37,39,40
22053 FBO32/750/6/ECO 16 20000 5000 75 2625 2363 1,2,
6,8,20,21,37
PENTRON®T5 LAMPS
PENTRON®T5 lamps are designed to operate on dedicated electronic programmed rapid start (also known as programmed start) ballasts only. These lamps are
globally standardized and are designed to operate with their peak light output at 35°C (95°F) ambient temperature. For comparison purposes and to accommo-
date existing lamp measurement standards, ratings are given at both 25°C (77°F) and 35°C (95°F). The new lamp dimensions allow for innovative fixture
designs and improved fixture performance. A PENTRON Fixture Design Guide is available on request.
PENTRON®High Performance T5 Lamps
45 Avg Approx Lumens
|
Nominal Avg Initial Mean
|
Nominal Length MOL Product Pkg Rated CCT @25°C/77°F Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI (@35°C/95°F) Footnotes
|
14 T5 24 22.2 Mini Bipin 20810 FP14/830 40 20000 3000 82 1200 1116 1,2,8,9,11
1350 1256
20907 FP14/830/ECO 40 20000 3000 82 1200 1116 1,2,6,
1350 1256 8,9,11
20812 FP14/835 40 20000 3500 82 1200 1116 1,2,8,9,11
1350 1256
20908 FP14/835/ECO 40 20000 3500 82 1200 1116 1,2,6,
1350 1256 8,9,11
20822 FP14/841 40 20000 4100 82 1200 1116 1,2,8,9,11
1350 1256
20914 FP14/841/ECO 40 20000 4100 82 1200 1116 1,2,6,
1350 1256 8,9,11
21 T5 36 34 Mini Bipin 20823 FP21/830 40 20000 3000 82 1900 1767 1,2,8,9,11
2100 1953
20919 FP21/830/ECO 40 20000 3000 82 1900 1767 1,2,6,
2100 1953 8,9,11
20832 FP21/835 40 20000 3500 82 1900 1767 1,2,8,9,11
2100 1953
20921 FP21/835/ECO 40 20000 3500 82 1890 1767 1,2,6,
2100 1953 8,9,11
20835 FP21/841 40 20000 4100 82 1900 1767 1,2,8,9,11
2100 1953
F
L
U
O
R
E
S
C
E
N
T
T5 Mini Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
121
PENTRON®T5 LAMPS
PENTRON®High Performance T5 Lamps
45 Avg Approx Lumens
|
Nominal Avg Initial Mean
|
Nominal Length MOL Product Pkg Rated CCT @25°C/77°F Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI (@35°C/95°F) Footnotes
|
21 T5 36 34 Mini Bipin 20924 FP21/841/ECO 40 20000 4100 82 1890 1767 1,2,6,
2100 1953 8,9,11
28 T5 48 45.8 Mini Bipin 20838 FP28/60[RED] 40 10000 2100 1,2,8,9,11
20839 FP28/66[GREEN] 40 10000 3500 1,2,8,9,11
20840 FP28/67[BLUE] 40 10000 700 1,2,8,9,11
20836 FP28/830 40 20000 3000 82 2600 2418 1,2,8,9,11
2900 2697
20868 FP28/830/ECO 40 20000 3000 82 2600 2418 1,2,6,
2900 2697 8,9,11
20841 FP28/835 40 20000 3500 82 2600 2418 1,2,8,9,11
2900 2697
20901 FP28/835/ECO 40 20000 3500 82 2600 2418 1,2,6,
2900 2697 8,9,11
20842 FP28/841 40 20000 4100 82 2600 2418 1,2,8,9,11
2900 2697
20902 FP28/841/ECO 40 20000 4100 82 2600 2418 1,2,6,
2900 2697 8,9,11
35 T5 60 57.6 Mini Bipin 20843 FP35/830 40 20000 3000 82 3300 3069 1,2,8,9,11
3650 3394
20925 FP35/830/ECO 40 20000 3000 82 3300 3069 1,2,6,
3650 3394 8,9,11
20844 FP35/835 40 20000 3500 82 3300 3069 1,2,8,9,11
3650 3394
20926 FP35/835/ECO 40 20000 3500 82 3300 3069 1,2,6,
3650 3394 8,9,11
20845 FP35/841 40 20000 4100 82 3300 3069 1,2,8,9,11
3650 3394
20927 FP35/841/ECO 40 20000 4100 82 3300 3069 1,2,6,
3650 3394 8,9,11
PENTRON®High Output, High Performance T5 Lamps
45 Avg Approx Lumens
|
Nominal Avg Initial Mean
|
Nominal Length MOL Product Pkg Rated CCT @25°C/77°F Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI (@35°C/95°F) Footnotes
|
24 T5 24 22.2 Mini Bipin 20846 FP24/830/HO 40 20000 3000 82 1750 1627 1,2,8,9,11
2000 1860
20928 FP24/830/HO/ECO 40 20000 3000 82 1750 1627 1,2,6,
2000 1860 8,9,11
20852 FP24/835/HO 40 20000 3500 82 1750 1627 1,2,8,9,11
2000 1860
20929 FP24/835/HO/ECO 40 20000 3500 82 1760 1627 1,2,6,
2000 1860 8,9,11
20853 FP24/841/HO 40 20000 4100 82 1750 1627 1,2,8,9,11
2000 1860
20931 FP24/841/HO/ECO 40 20000 4100 82 1760 1627 1,2,6,
2000 1860 8,9,11
39 T5 36 34 Mini Bipin 20854 FP39/830/HO 40 20000 3000 82 3100 2883 1,2,8,9,11
3500 3255
F
L
U
O
R
E
S
C
E
N
T
T5 Mini Bipin Circline 4-Pin T5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
122
PENTRON®T5 LAMPS
PENTRON®High Output, High Performance T5 Lamps
45 Avg Approx Lumens
|
Nominal Avg Initial Mean
|
Nominal Length MOL Product Pkg Rated CCT @25°C/77°F Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI (@35°C/95°F) Footnotes
|
39 T5 36 34 Mini Bipin 20932 FP39/830/HO/ECO 40 20000 3000 82 3100 2883 1,2,6,
3500 3255 8,9,11
20855 FP39/835/HO 40 20000 3500 82 3100 2883 1,2,8,9,11
3500 3255
20933 FP39/835/HO/ECO 40 20000 3500 82 3100 2883 1,2,6,
3500 3255 8,9,11
20856 FP39/841/HO 40 20000 4100 82 3100 2883 1,2,8,9,11
3500 3255
20934 FP39/841/HO/ECO 40 20000 4100 82 3100 2883 1,2,6,
3500 3255 8,9,11
54 T5 48 45.8 Mini Bipin 20857 FP54/830/HO 40 20000 3000 82 4450 4138 1,2,8,9,11
5000 4650
20903 FP54/830/HO/ECO 40 20000 3000 82 4450 4138 1,2,6,
5000 4650 8,9,11
20858 FP54/835/HO 40 20000 3500 82 4450 4138 1,2,8,9,11
5000 4650
20904 FP54/835/HO/ECO 40 20000 3500 82 4450 4138 1,2,6,
5000 4650 8,9,11
20860 FP54/841/HO 40 20000 4100 82 4450 4138 1,2,8,9,11
5000 4650
20906 FP54/841/HO/ECO 40 20000 4100 82 4450 4138 1,2,6,
5000 4650 8,9,11
20862 FP54/860/HO/ECO 40 20000 6000 82 4050 3766 1,2,6,
5000 4418 8,9,11
80 T5 60 57.6 Mini Bipin 20863 FP80/830/HO 40 20000 3000 82 6150 5719 1,2,8,9,11
7000 6510
20935 FP80/830/HO/ECO 40 20000 3000 82 6150 5719 1,2,6,
7000 6510 8,9,11
20864 FP80/835/HO 40 20000 3500 82 6150 5719 1,2,8,9,11
7000 6510
20936 FP80/835/HO/ECO 40 20000 3500 82 6150 5719 1,2,6,
7000 6510 8,9,11
20865 FP80/841/HO 40 20000 4100 82 6150 5719 1,2,8,9,11
7000 6510
20937 FP80/841/HO/ECO 40 20000 4100 82 6150 5719 1,2,6,
7000 6510 8,9,11
PENTRON®Circline T5 Lamps
46 Avg Avg Approx Lumens
|
Nominal Outside Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb Diameter (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
22 T5 8.66 - 9.06 2GX13 20702 FPC22/830 12 12000 3000 82 1800 1585 1,2,8,9,11
20712 FPC22/835 12 12000 3500 82 1800 1585 1,2,8,9,11
20715 FPC22/841 12 12000 4100 82 1800 1585 1,2,8,9,11
40 T5 11.54 - 12.01 2GX13 20731 FPC40/830 12 12000 3000 82 3200 2815 1,2,8,9,11
20732 FPC40/835 12 12000 3500 82 3200 2815 1,2,8,9,11
20733 FPC40/841 12 12000 4100 82 3200 2815 1,2,8,9,11
F
L
U
O
R
E
S
C
E
N
T
Circline 4-Pin T5 T12 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
123
PENTRON®T5 LAMPS
PENTRON®Circline T5 Lamps
46 Avg Avg Approx Lumens
|
Nominal Outside Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb Diameter (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
55 T5 11.54 - 12.01 2GX13 20741 FPC55/830/HO 12 12000 3000 82 4000 3520 1,2,8,9,11
20750 FPC55/835/HO 12 12000 3500 82 4000 3520 1,2,8,9,11
20751 FPC55/841/HO 12 12000 4100 82 4000 3520 1,2,8,9,11
RAPID START LAMPS
3' SUPERSAVER®Rapid Start Lamps
Rapid start lamps, 3-foot and 4-foot in length, are typically designated by their wattage: e.g. F40 = Fluorescent 40W. Therefore, lamps previously designated as
F30T12/RS/SS, F40/SS and FB40/SS energy saving types will now be designated as F25T12/RS/SS, F34/SS and FB34/SS, respectively, to comply with standard
lamp designation nomenclature for these families of lamps.
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
25 T12 36 35.78 Med Bipin 23451 F25T12/D30/RS/SS 30 18000 3000 70 2050 1804 1,2,42
formerly F30T12/D30/RS/SS
23473 F25T12/WW/RS/SS 30 18000 3000 52 1975 1679 1,2,42
formerly F30T12/WW/RS/SS
23485 F25T12/D35/RS/SS 30 18000 3500 70 2050 1804 1,2,42
formerly F30T12/D35/RS/SS
23472 F25T12/CW/RS/SS 30 18000 4200 62 1925 1636 1,2,42
formerly F30T12/CW/RS/SS
3' Standard Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
30 T12 36 35.78 Med Bipin 23474 F30T12/D830/RS 30 18000 3000 80 2290 2061 1,2,8,43
23490 F30T12/WW/RP 618000 3000 52 2275 1934 1,2,8,43
23482 F30T12/WW/RS 30 18000 3000 52 2275 1934 1,2,8,43
23484 F30T12/D35/RS 30 18000 3500 70 2250 1980 1,2,8,43
23139 F30T12/D835/RS 30 18000 3500 80 2290 2061 1,2,8,43
23477 F30T12/CWX/RS 30 18000 4100 87 1600 1360 1,2,8,43
23488 F30T12/D41/RS 30 18000 4100 70 2250 1980 1,2,8,43
23493 F30T12/CW/RP 618000 4200 62 2200 1870 1,2,8,43
23476 F30T12/CW/RS 30 18000 4200 62 2200 1870 1,2,8,43
23487 F30T12/CW/RS/UPC 30 18000 4200 62 2200 1870 1,2,8,43
23478 F30T12/D/RS 30 18000 6500 76 1900 1615 1,2,8,43
4' SUPERSAVER®Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
34 T12 48 47.78 Med Bipin 24535 F34/D30/SS/ECO 30 20000 3000 70 2800 2520 1,2,6,
formerly F40/D30/SS/ECO 43,44,45,46
24589 F34/D830/SS 30 20000 3000 80 2900 2610 1,2,43,
formerly F40/D830/SS 44,45,46
24544 F34/D830/SS/ECO 30 20000 3000 80 2900 2610 1,2,
formerly F40/D830/SS/ECO 6,43,44,45,46
24595 F34WW/SS 30 20000 3000 52 2750 2365 1,2,43,44,45,
formerly F40WW/SS 46
F
L
U
O
R
E
S
C
E
N
T
T12 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
124
RAPID START LAMPS
4' SUPERSAVER®Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
34 T12 48 47.78 Med Bipin 24538 F34WW/SS/ECO 30 20000 3000 52 2750 2365 1,2,6,
formerly F40WW/SS/ECO 43,44,45,46
24591 F34W/SS 30 20000 3450 57 2750 2365 1,2,43,44,45,
formerly F40W/SS 46
24585 F34/D35/SS 30 20000 3500 70 2800 2520 1,2,43,
formerly F40/D35/SS 44,45,46
24522 F34/D35/SS/CVP 10 20000 3500 70 2800 2520 1,2,43,
formerly F40/D35/SS/CVP 44,45,46
24540 F34/D35/SS/ECO 30 20000 3500 70 2800 2520 1,2,6,
formerly F40/D35/SS/ECO 43,44,45,46
24547 F34/D835/SS/ECO 30 20000 3500 80 2900 2610 1,2,
formerly F40/D835/SS/ECO 6,43,44,45,46
24542 F34/D41/SS/ECO 30 20000 4100 70 2800 2520 1,2,6,
formerly F40/D41/SS/ECO 43,44,45,46
24554 F34/D841/SS/ECO 30 20000 4100 80 2900 2610 1,2,
formerly F40/D841/SS/ECO 6,43,44,45,46
24588 F34CWX/SS 30 20000 4100 87 1925 1656 1,2,43,44,45,
formerly F40CWX/SS 46
24590 F34LW/SS 30 20000 4150 48 2825 2430 1,2,43,44,45,
formerly F40LW/SS 46
24566 F34LW/SS/ECO 30 20000 4150 48 2825 2430 1,2,6,
formerly F40LW/SS/ECO 43,44,45,46
24508 F34CW/RS/SS/672PLT 672 20000 4200 62 2650 2279 1,2,43,44,45,
formerly F40CW/RS/SS/672PLT 46
24594 F34CW/SS 30 20000 4200 62 2650 2279 1,2,43,44,45,
formerly F40CW/SS 46
24516 F34CW/SS/10 10 20000 4200 62 2650 2279 1,2,43,44,45,
formerly F40CW/SS/10 46
24524 F34CW/SS/CVP 10 20000 4200 62 2650 2279 1,2,43,44,45,
formerly F40/CW/SS/CVP 46
24596 F34CW/SS/ECO 30 20000 4200 62 2650 2279 1,2,6,
formerly F40CW/SS/ECO 43,44,45,46
24396 F34CW/SS/SL 30 20000 4200 62 2600 2235 1,2,25,26,43,
formerly F40CW/SS/SL 44,45
28012 F34CW/SS/UPC 30 20000 4200 62 2650 2279 1,2,43,44,45,
formerly F40CW/SS/UPC 46
24706 F34/D865/SS 30 20000 6500 80 2650 2385 1,2,43,
formerly F40/D865/SS 44,45,46
24599 F34/DX/SS 30 20000 6500 88 1930 1565 1,2,43,44,45,
formerly F40/DX/SS 46
4' Standard Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
40 T12 48 47.78 Med Bipin 24673 F40/GO 10 20000 1980 1,2,8,43,44,46,
47
24454 F40IF 30 20000 2750 89 1480 1273 1,2,8,43,44,
46,47
F
L
U
O
R
E
S
C
E
N
T
T12 Med Bipin T12 U-Shaped (leg spacing of 3-5/8" or 6")
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
125
RAPID START LAMPS
4' Standard Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
40 T12 48 47.78 Med Bipin 24521 F40/D30/ECO 30 20000 3000 70 3200 2880 1,2,
6,8,43,44,46,47
24543 F40/D830/ECO 30 20000 3000 80 3300 2970 1,2,
6,8,43,44,46,47
24537 F40/D35/ECO 30 20000 3500 70 3200 2880 1,2,
6,8,43,44,46,47
24546 F40/D835/ECO 30 20000 3500 80 3300 2970 1,2,
6,8,43,44,46,47
24438 F40N 30 20000 3600 86 2100 1806 1,2,8,43,44,
46,47
24584 F40/D41 30 20000 4100 70 3200 2880 1,2,8,
43,44,46,47
24541 F40/D41/ECO 30 20000 4100 70 3200 2880 1,2,
6,8,43,44,46,47
24553 F40/D841/ECO 30 20000 4100 80 3300 2970 1,2,
6,8,43,44,46,47
24442 F40CWX 10 20000 4100 87 2150 1849 1,2,8,43,44,
46,47
24441 F40CWX 30 20000 4100 87 2150 1849 1,2,8,43,44,
46,47
24683 F40DSGN50 30 20000 5000 90 2200 1892 1,2,8,43,44,
46,47
24570 F40/D865 30 20000 6500 80 3000 2700 1,2,8,
43,44,46,47
24477 F40/DX 30 20000 6500 88 2180 1770 1,2,8,43,44,
46,47
CURVALUME®Rapid Start SUPERSAVER®- U-Shaped, 6" Leg Spacing
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
34 T12 22.5 22.6 Med Bipin 24063 FB34/D30/6/SS 12 18000 3000 70 2730 2457 1,2,43,
formerly FB40/D30/6/SS 45
24047 FB34/WW/6/SS 12 18000 3000 52 2650 2279 1,2,43,45
formerly FB40/WW/6/SS
24052 FB34/WW/6/SS/ECO 12 18000 3000 52 2650 2279 1,2,6,
formelry FB40/WW/6/SS/ECO 43,45
24062 FB34/WW/6/SS/UPC 12 18000 3000 52 2650 2279 1,2,43,45
formerly FB40/WW/6/SS
24065 FB34/D35/6/SS 12 18000 3500 70 2730 2457 1,2,43,
formerly FB40/D35/SS 45
24067 FB34/D41/6/SS 12 18000 4100 70 2730 2457 1,2,43,
formerly FB40/D41/SS 45
24049 FB34/LW/6/SS 12 18000 4150 48 2800 2408 1,2,43,45
formerly FB40/LW/6/SS
24046 FB34/CW/6/SS 12 18000 4200 62 2600 2236 1,2,43,45
formerly FB40/CW/6/SS
24054 FB34/CW/6/SS/ECO 12 18000 4200 62 2600 2236 1,2,6,
formerly FB40/CW/6/SS/ECO 43,45
F
L
U
O
R
E
S
C
E
N
T
T12 Med Bipin Circline 4-Pin T9 T12 RDC
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
126
RAPID START LAMPS
CURVALUME®Rapid Start SUPERSAVER®- U-Shaped, 6" Leg Spacing
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
34 T12 22.5 22.6 Med Bipin 24059 FB34/CW/6/SS/UPC 12 18000 4200 62 2600 2236 1,2,43,45
formerly FB40/CW/SS/6
CURVALUME®Rapid Start Standard Lamps - U-Shaped, 6" Leg Spacing
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
40 T12 22.5 22.6 Med Bipin 24080 FB40/D30/6 12 18000 3000 70 3050 2745 1,2,8,
43
24017 FB40/D830/6 12 18000 3000 80 3200 2880 1,2,8,
43
24081 FB40/D35/6 12 18000 3500 70 3050 2745 1,2,8,
43
24004 FB40/CWX/6 12 18000 4100 87 2100 1806 1,2,8,43
24082 FB40/D41/6 12 18000 4100 70 3050 2745 1,2,8,
43
Circline T9 Rapid Start Lamps
46 Avg Avg Approx Lumens
|
Nominal Outside Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb Diameter (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
20 T9 6.25-6.75 4 Pin 20155 FC6T9/WW/RS 12 8000 3000 52 800 696 1,2,8,48
20156 FC6T9/CW/RS 12 8000 4200 62 750 653 1,2,8,48
22 T9 8.00-8.50 4 Pin 20209 FC8T9/DWW/RP 612000 3000 70 1100 990 1,2,8,48
20088 FC8T9/WW/RS 12 12000 3000 52 1050 914 1,2,8,48
20148 FC8T9/CW/RS 12 12000 4200 62 1050 914 1,2,8,48
20151 FC8T9/CW/RS/6 PACK 612000 4200 62 1050 914 1,2,8,48
20080 FC8T9/D/RS 12 12000 6500 76 900 783 1,2,8,48
30 T9 8.00-8.50 4 Pin 20210 FC8T9/830/EL 610000 3000 80 1850 1591 1,2,3,16,17,
49
32 T9 11.50-12.0 4 Pin 20233 FC12T9/DWW/RP 615000 3000 70 2100 1806 1,2,8,48
20037 FC12T9/WW/RS 12 15000 3000 52 1950 1697 1,2,8,48
20142 FC12T9/CW/RS 12 15000 4200 62 1925 1675 1,2,8,48
20143 FC12T9/CW/RS/6 PACK 615000 4200 62 1925 1675 1,2,8,48
20030 FC12T9/D/RS 12 15000 6500 76 1650 1436 1,2,8,48
40 T9 15.5-16 4 Pin 20057 FC16T9/WW/RS 12 18000 3000 52 2800 2436 1,2,8,48
20132 FC16T9/CW/RS 12 18000 4200 62 2750 2393 1,2,8,48
20072 FC16T9/D/RS 12 18000 6500 76 2350 2045 1,2,8,48
High Output (800mA) Rapid Start SUPERSAVER®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
55 T12 48 46 Recessed DC 25137 F48T12D35/HO/SS 30 12000 3500 70 3750 3375 1,2,50,51
95 T12 96 93.91 Recessed DC 25008 F96T12/D830/HO/SS 15 12000 3000 80 8750 8050 1,2,50,
51
25011 F96T12/WW/HO/SS 15 12000 3000 52 7700 6237 1,2,50,51
F
L
U
O
R
E
S
C
E
N
T
T12 RDC
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
127
RAPID START LAMPS
High Output (800mA) Rapid Start SUPERSAVER®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
95 T12 96 93.91 Recessed DC 25024 F96T12/D35/HO/SS 15 12000 3500 48 8350 7515 1,2,50,
51
25001 F96T12/CW/HO/SS/ECO 15 12000 4050 62 8000 6480 1,2,6,50,51
25023 F96T12/D41/HO/SS 15 12000 4100 70 8350 7515 1,2,50,
51
25025 F96T12/LW/HO/SS 15 12000 4150 48 8000 6480 1,2,50,51
25010 F96T12/CW/HO/SS 15 12000 4200 62 8000 6480 1,2,50,51
High Output (800mA) Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
25 T12 18 15.91 Recessed DC 25303 F18T12/DSGN50/HO 30 9000 5000 90 850 740 1,2,8
35 T12 24 21.91 Recessed DC 25313 F24T12/CW/HO 30 9000 4200 62 1650 1337 1,2,8
25312 F24T12/DSGN50/HO 30 9000 5000 90 1200 1044 1,2,8
25314 F24T12/D/HO 30 9000 6500 76 1400 1134 1,2,8
42 T12 30 27.91 Recessed DC 25322 F30T12/CW/HO 30 9000 4200 62 2250 1825 1,2,8
45 T12 36 33.91 Recessed DC 25333 F36T12/CW/HO 30 9000 4200 62 2850 2309 1,2,8
25334 F36T12/DSGN50/HO 30 9000 5000 90 2100 1701 1,2,8
25332 F36T12/D/HO 30 9000 6500 76 2500 2025 1,2,8
55 T12 42 39.91 Recessed DC 25342 F42T12/CW/HO 30 9000 4200 62 3400 2754 1,2,8
25344 F42T12/DSGN50/HO 30 9000 5000 90 2550 2066 1,2,8
25343 F42T12/D/HO 30 9000 6500 76 3050 2471 1,2,8
60 T12 48 46 Recessed DC 25148 F48T12/D830/HO 30 12000 3000 80 4400 4048 1,2,8,51
25147 F48T12/WW/HO 30 12000 3000 52 4130 3345 1,2,8,51
25154 F48T12/D35/HO 30 12000 3500 70 4250 3825 1,2,8,51
25144 F48T12/CWX/HO 30 12000 4100 87 2800 2268 1,2,8,51
25136 F48T12/D41/HO 30 12000 4100 70 4250 3443 1,2,8,51
25146 F48T12/CW/HO 30 12000 4200 62 4050 3281 1,2,8,51
25122 F48T12/CW/HO/ECO 30 12000 4200 62 4050 3281 1,2,6,8,51
25153 F48T12/DSGN50/HO 30 12000 5000 90 3050 2471 1,2,8,51
25150 F48T12/D/HO 30 12000 6500 76 3600 2916 1,2,8,51
75 T12 60 57.91 Recessed DC 25127 F60T12/WW/HO 30 12000 3000 52 5250 4253 1,2,8,51
25128 F60T12/D35/HO 30 12000 3500 70 5600 5040 1,2,8,51
25126 F60T12/CW/HO 30 12000 4200 62 5200 4212 1,2,8,51
25119 F60T12/DSGN50/HO 30 12000 5000 90 3850 3119 1,2,8,51
25120 F60T12/D/HO 30 12000 6500 76 4600 3826 1,2,8,51
80 T12 64 61.91 Recessed DC 25352 F64T12/CW/HO 30 12000 4200 62 5750 4658 1,2,8,51
25355 F64T12/DSGN50/HO 30 12000 5000 90 4200 3402 1,2,8,51
25353 F64T12/D/HO 30 12000 6500 76 4900 3969 1,2,8,51
85 T12 72 69.91 Recessed DC 25097 F72T12/D30/HO 15 12000 3000 70 6650 5985 1,2,8,51,52
25098 F72T12/D830/HO 15 12000 3000 80 6750 6210 1,2,8,51,52
F
L
U
O
R
E
S
C
E
N
T
T12 RDC
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
128
RAPID START LAMPS
High Output (800mA) Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
85 T12 72 69.91 Recessed DC 25177 F72T12/WW/HO 15 12000 3000 52 6400 5184 1,2,8,51,52
27249 F72T12/D35/HO 15 12000 3500 70 6650 5985 1,2,8,51,52
25281 F72T12/D835/HO 15 12000 3500 80 6750 6210 1,2,8,51,52
25182 F72T12/N/HO 15 12000 3600 86 4400 3564 1,2,8,51,52
25187 F72T12/CWX/HO 15 12000 4100 87 4560 3694 1,2,8,51,52
27245 F72T12/D41/HO 15 12000 4100 70 6650 5985 1,2,8,51,52
25176 F72T12/CW/HO 15 12000 4200 62 6250 5063 1,2,8,51,52
25171 F72T12/CW/HO/ECO 15 12000 4200 62 6250 5063 1,2,6,8,52
25190 F72T12/DSGN50/HO 15 12000 5000 90 4600 3726 1,2,8,51
25189 F72T12/D/HO 15 12000 6500 76 5550 4496 1,2,8,51,52
100 T12 84 81.91 Recessed DC 25383 F84T12/D35/HO 15 12000 3500 70 7880 7092 1,2,8,51
25384 F84T12/CW/HO 15 12000 4200 62 7550 6115 1,2,8,51
25386 F84T12/DSGN50/HO 15 12000 5000 90 5600 4536 1,2,8,51
25385 F84T12/D/HO 15 12000 6500 76 6700 5427 1,2,8,51
110 T12 96 93.91 Recessed DC 25149 F96T12/D30/HO 15 12000 3000 70 9050 8145 1,2,8,
51
25152 F96T12/D830/HO 15 12000 3000 80 9400 8648 1,2,8,
51
25165 F96T12/D35/HO 15 12000 3500 70 9050 8145 1,2,8,
51
25166 F96T12/D835/HO 15 12000 3500 80 9400 8648 1,2,8,
51
25162 F96T12/N/HO 15 12000 3600 86 6050 4900 1,2,8,51
25158 F96T12/CWX/HO 15 12000 4100 87 6100 5307 1,2,8,51
25184 F96T12/D41/HO 15 12000 4100 70 9050 8145 1,2,8,
51
25114 F96T12/D841/HO 15 12000 4100 80 9400 8648 1,2,8,51
25129 F96T12/CW/HO/CT/ECO 15 12000 4200 62 8600 6966 1,2,6,8,51,
53
25164 F96T12/DSGN50/HO 15 12000 5000 90 6450 5225 1,2,8,51
25185 F96T12/D865/HO 15 12000 6500 80 8800 7920 1,2,8,
51
High Output (800mA) Rapid Start Lamps for Cold Temperature Operation
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
110 T12 96 93.91 Recessed DC 25134 F96T12/CW/HO/COLD TEMP 15 12000 4200 62 8600 6966 1,2,8,51,53
25118 F96T12/CW/HO/COLD/10/CVP 10 12000 4200 62 8600 6966 1,2,8,51,53
25129 F96T12/CW/HO/CT/ECO 15 12000 4200 62 8600 6966 1,2,6,8,51,
53
25135 F96T12/D/HO/COLD TEMP 15 12000 6500 76 7600 6156 1,2,8,51,53
F
L
U
O
R
E
S
C
E
N
T
T12 RDC T8 Single Pin T12 Single Pin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
129
RAPID START LAMPS
Very High Output (1500mA) Rapid Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
115 T12 48 46 Recessed DC 25248 F48T12/CW/VHO 30 10000 4200 62 6600 4620 1,2,8,54
25249 F48T12/CW/VHO/LT 30 10000 4200 62 6750 5250 1,2,8,54,55,56
21260 F48T12/CW/VHO/PB/30 610000 4200 62 1,2,8,57
25244 F48T12/D/VHO 30 10000 6500 76 5600 3920 1,2,8,54
135 T12 60 57.91 Recessed DC 25262 F60T12/CW/VHO 30 10000 4200 62 8700 6090 1,2,8,54
141 T12 60 57.91 Recessed DC 25263 F60T12/CW/VHO/LT 30 10000 4200 62 8700 6090 1,2,8,54,55,56
160 T12 72 69.91 Recessed DC 25272 F72T12/CW/VHO 15 10000 4200 62 10600 7420 1,2,8,54
25274 F72T12/CW/VHO/LT 15 10000 4200 62 11000 7700 1,2,8,54,55,56
25270 F72T12/D/VHO 15 10000 6500 76 9400 6580 1,2,8,54
195 T12 96 93.91 Recessed DC 25296 F96T12/CW/VHO/SS 15 10000 4200 62 13000 9100 1,2,8,54,58
215 T12 96 93.91 Recessed DC 25211 F96T12/WW/VHO 15 10000 3000 52 14000 9800 1,2,8,54
25209 F96T12/CW/VHO 15 10000 4200 62 14000 9800 1,2,8,54
25292 F96T12/CW/VHO/LT 15 10000 4200 62 15000 10500 1,2,8,54,55,56
25210 F96T12/D/VHO 15 10000 6500 76 11600 8120 1,2,8,54
INSTANT START LAMPS
Slimline Instant Start SUPERSAVER®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
32 T12 48 46.00 Single Pin 24829 F48T12/D35/SS 30 9000 3500 70 2575 2369 1,2,59
24825 F48T12/D41/SS 30 9000 4100 70 2575 2369 1,2,59
24823 F48T12/CW/SS 30 9000 4200 62 2450 2200 1,2,59
60 T12 96 94 Single Pin 29825 F96T12/D30/SS 15 12000 3000 70 5600 5152 1,2,51,
59
29809 F96T12/D30/SS/ECO 15 12000 3000 70 5600 5152 1,2,
6,51,59
29823 F96T12/D830/SS 15 12000 3000 80 5800 5452 1,2,51,
59
29854 F96T12/D830/SS/ECO 15 12000 3000 80 5800 5452 1,2,
6,51,59
29795 F96T12/WW/SS/ECO 15 12000 3000 52 5500 4840 1,2,6,
51,59
29819 F96T12/D35/SS 15 12000 3500 70 5600 5152 1,2,51,
59
29808 F96T12/D35/SS/ECO 15 12000 3500 70 5600 5152 1,2,
6,51,59
29811 F96T12/D835/SS 15 12000 3500 80 5800 5452 1,2,51,
59
29859 F96T12/D835/SS/ECO 15 12000 3500 80 5800 5452 1,2,
6,51,59
29814 F96T12/CWX/SS 15 12000 4100 87 3850 3388 1,2,51,59
29853 F96T12/D41/SS/ECO 15 12000 4100 70 5600 5152 1,2,
6,51,59
29812 F96T12/D841/SS 15 12000 4100 80 5800 5452 1,2,51,
59
F
L
U
O
R
E
S
C
E
N
T
T12 Single Pin T6 Single Pin T8 Single Pin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
130
INSTANT START LAMPS
Slimline Instant Start SUPERSAVER®Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
60 T12 96 94 Single Pin 29860 F96T12/D841/SS/ECO 15 12000 4100 80 5800 5452 1,2,
6,51,59
29820 F96T12/LW/SS 15 12000 4150 48 5600 4928 1,2,51,59
29815 F96T12/CW/SS 15 12000 4200 62 5300 4664 1,2,51,59
29805 F96T12/CW/SS/CVP 10 12000 4200 62 5300 4664 1,2,51,59
29505 F96T12/CW/SS/ECO 15 12000 4200 62 5300 4664 1,2,6,
51,59
29816 F96T12/CW/SS/UPC 15 12000 4200 62 5300 4664 1,2,51,59
29851 F96T12/D865/SS 15 12000 6500 80 5300 4770 1,2,51,
59
29828 F96T12/DX/SS 15 12000 6500 88 3860 3397 1,2,51,59
29868 F96T12/DX/SS/ECO 15 12000 6500 88 3860 3397 1,2,6,
51,59
Slimline Instant Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
21 T12 24 22.0 Single Pin 22403 F24T12/CW 30 7500 4200 62 1150 1000 1,2,8
25 T6 42 40 Single Pin 24270 F42T6/WW 24 7500 3032 52 1825 1606 1,2,8
24269 F42T6/D35 24 7500 3500 70 1830 1684 1,2,8
24266 F42T6/CW 24 7500 4200 62 1750 1540 1,2,8
30 T12 36 34 Single Pin 23618 F36T12/CW 30 7500 4200 62 1970 1734 1,2,8
38 T6 64 62 Single Pin 26470 F64T6/WW 24 7500 3000 52 2900 2552 1,2,8
26469 F64T6/D35 24 7500 3500 70 2930 2696 1,2,8
26466 F64T6/CW 24 7500 4200 62 2800 2464 1,2,8
T8 72 70 Single Pin 27270 F72T8/WW 24 7500 3000 52 3100 2728 1,2,8
27266 F72T8/CW 24 7500 4200 62 3050 2684 1,2,8
27200 F72T8/D 24 7500 6500 76 2600 2288 1,2,8
39 T12 48 46 Single Pin 24827 F48T12/CW/ECO 30 9000 4200 62 2820 2482 1,2,6,8
24836 F48T12D/ECO 30 9000 6500 76 2450 2156 1,2,6,
8
24832 F48T12/D35 30 9000 3500 70 3000 2760 1,2,8
24830 F48T12/CW 30 9000 4200 62 2820 2482 1,2,8
24834 F48T12/D 30 9000 6500 76 2450 2156 1,2,8
50 T12 60 58 Single Pin 26018 F60T12/D35 30 12000 3500 70 3850 3542 1,2,8,51
26001 F60T12/CW 30 12000 4200 62 3700 3256 1,2,8,51
26002 F60T12/D 30 12000 6500 76 3000 2640 1,2,8,51
51 T8 96 94 Single Pin 29666 F96T8/CW 24 7500 4200 62 4000 3520 1,2,8
29650 F96T8/D 24 7500 6500 76 3550 3124 1,2,8
52 T12 64 62 Single Pin 26403 F64T12/CW 30 12000 4200 62 3900 3432 1,2,8,51
26404 F64T12/D 30 12000 6500 76 3300 2904 1,2,8,51
55 T12 72 70 Single Pin 27255 F72T12/D830 15 12000 3000 80 4800 4512 1,2,8,51
F
L
U
O
R
E
S
C
E
N
T
T12 Single Pin T12 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
131
INSTANT START LAMPS
Slimline Instant Start Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
55 T12 72 70 Single Pin 27250 F72T12/D35 15 12000 3500 70 4700 4324 1,2,8,51
27243 F72T12/D41 15 12000 4100 70 4700 4324 1,2,8,51
27256 F72T12/CW 15 12000 4200 62 4500 3960 1,2,8,51
27259 F72T12/D 15 12000 6500 76 3800 3432 1,2,8,51
70 T12 84 82 Single Pin 28417 F84T12/CW 15 12000 4200 62 5300 4664 1,2,8,51
75 T12 96 94 Single Pin 29818 F96T12/D30 15 12000 3000 70 6420 5906 1,2,8,
51
29796 F96T12/D30/ECO 15 12000 3000 70 6420 5906 1,2,
6,51
29827 F96T12/D830 15 12000 3000 80 6550 6157 1,2,8,
51
29856 F96T12/D830/ECO 15 12000 3000 80 6550 6157 1,2,
6,8,51
29685 F96T12/D35 15 12000 3500 70 6420 5906 1,2,8,
51
29686 F96T12/D35/ECO 15 12000 3500 70 6420 5906 1,2,
6,8,51
29843 F96T12/D835 15 12000 3500 80 6550 6157 1,2,8,
51
29838 F96T12/D835/ECO 15 12000 3500 80 6550 6157 1,2,
6,8,51
29478 F96T12/CWX 15 12000 4100 87 4400 3872 1,2,8,51
29858 F96T12/CWX/CVP 10 12000 4100 87 4400 3872 1,2,8,51
29489 F96T12/CWX/UPC 15 12000 4100 87 4400 3872 1,2,8,51
29797 F96T12/D41/CVP 10 12000 4100 70 6420 5906 1,2,8,
51
29798 F96T12/D41/ECO 15 12000 4100 70 6420 5906 1,2,
6,8,51
29852 F96T12/D41/UPC 15 12000 4100 70 6420 5906 1,2,8,
51
29857 F96T12/D841 15 12000 4100 80 6550 6157 1,2,8,
51
29850 F96T12/D841/ECO 15 12000 4100 80 6550 6157 1,2,
6,8,51
29833 F96T12/DSGN50 15 12000 5000 90 4400 3872 1,2,8,51
29849 F96T12/D865 15 12000 6500 80 6000 5520 1,2,8,
51
29500 F96T12/DX 15 12000 6500 88 4360 3837 1,2,8,51
Instant Start Bipin Lamp
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
40 T12 48 47.78 Med Bipin 24571 F40T12/CW/IS 30 9000 4200 62 3000 2640 1,2,8,60
F
L
U
O
R
E
S
C
E
N
T
T5 Mini Bipin T8 Med Bipin T12 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
132
PREHEAT LAMPS
Miniature T5 Preheat Lamps (Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
4T5 6 5.91 Mini Bipin 20416 F4T5/CW 24 6000 4200 62 135 117 1,2
20415 F4T5CW/BL/1/6 66000 4200 62 135 117 1,2
20420 F4T5/D 24 6000 6500 76 115 100 1,2
6T5 9 8.91 Mini Bipin 20617 F6T5/WW 24 7500 3000 52 275 239 1,2
20616 F6T5/CW 24 7500 4200 62 270 235 1,2
20619 F6T5CW/BL/1/6 67500 4200 62 270 235 1,2
20620 F6T5/D 24 7500 6500 76 260 226 1,2
8T5 12 11.91 Mini Bipin 20817 F8T5/WW 24 7500 3000 52 400 348 1,2
20819 F8T5/WW/BL/1/6 67500 3000 52 400 348 1,2
20821 F8T5/W 24 7500 3450 57 400 348 1,2
20837 F8T5/CWX 24 7500 4100 87 270 235 1,2
20816 F8T5/CW 24 7500 4200 62 390 339 1,2
20834 F8T5CW/BL/1/6 67500 4200 62 390 339 1,2
20824 F8T5/DSGN50 24 7500 5000 90 280 244 1,2
20820 F8T5/D 24 7500 6500 76 350 305 1,2
13 T5 21 20.4 Mini Bipin 21301 L13W/25 25 7500 4000 75 700 630 1,2
20.91 Mini Bipin 21317 F13T5/WW 24 7500 3000 52 880 766 1,2
21332 F13T5/WW/BL/1/6 67500 3000 52 880 766 1,2
21316 F13T5/CW 24 7500 4200 62 860 748 1,2
21315 F13T5CW/BL/1/6 67500 4200 62 860 748 1,2
Standard T8 and T12 Preheat Lamps (Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
13 T8 12 11.71 Med Bipin 21766 F13T8/CW 24 7500 4200 62 530 461 1,2
14 T8 15 14.78 Med Bipin 21486 F14T8/CW 24 7500 4200 62 685 644 1,2
21488 F14T8/D 24 7500 6500 76 575 561 1,2
T12 15 14.78 Med Bipin 21451 F14T12/DWW/RP 69000 3000 70 720 648 1,2
21435 F14T12/WW 30 9000 3000 52 660 574 1,2
21536 F14T12/DCW/1/6/RP 69000 4100 70 720 648 1,2
21409 F14T12/CW 30 9000 4200 62 650 566 1,2
21410 F14T12/CW/6/RP 69000 4200 62 650 566 1,2
21411 F14T12/D 30 9000 6500 76 590 513 1,2
15 T8 18 17.78 Med Bipin 21610 F15T8/D830 24 7500 3000 82 920 846 1,2
21701 F15T8/WW 24 7500 3000 52 845 735 1,2
21765 F15T8/WW/RP 67500 3000 52 845 735 1,2
21609 F15T8/D35 24 7500 3500 70 940 846 1,2
21682 F15T8/N 24 7500 3600 86 560 487 1,2
21627 F15T8/CWX 24 7500 4100 87 600 522 1,2
21603 F15T8/DCW/RP 67500 4100 70 900 810 1,2
F
L
U
O
R
E
S
C
E
N
T
T8 Med Bipin T12 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
133
PREHEAT LAMPS
Standard T8 and T12 Preheat Lamps (Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 T8 18 17.78 Med Bipin 21616 F15T8/CW 24 7500 4200 62 825 718 1,2
21619 F15T8/CW/6PK 67500 4200 62 825 718 1,2
21642 F15T8/DSGN50 24 7500 5000 90 600 539 1,2
21600 F15T8/D 24 7500 6500 76 700 653 1,2
T12 18 17.78 Med Bipin 21551 F15T12/DWW/RP 69000 3000 70 770 693 1,2
21542 F15T12/WW 30 9000 3000 52 770 670 1,2
21544 F15T12/WW/RP 69000 3000 52 770 670 1,2
21535 F15T12/DCW/RP 69000 4100 76 770 693 1,2
21532 F15T12/CW 30 9000 4200 62 750 653 1,2
21513 F15T12/CW 6PK 69000 4200 62 750 653 1,2
21534 F15T12/D 30 9000 6500 76 660 574 1,2
18 T8 24 23.78 Med Bipin 23014 F18T8CW/K24 24 7500 4200 62 1190 1035 1,2
23012 F18T8CW/K24/1/12/UPC 12 7500 4200 62 1190 1035 1,2
26 25.78 Med Bipin 23025 F18T8/CW/K26PLT 3168 7500 4200 62 1280 1079 1,2
23027 F18T8CW/K26 24 7500 4200 62 1280 1079 1,2
21728 F18T8/D/K26 24 7500 6500 76 1100 957 1,2
28 27.78 Med Bipin 23028 F18T8CW/K28 24 7500 4200 62 1360 1131 1,2
30 29.78 Med Bipin 23030 F18T8CW/K30 24 7500 4200 62 1400 1200 1,2
20 T12 21 20.78 Med Bipin 22080 F20T12/CW/21 30 7500 4200 62 1020 887 1,2
22 21.78 Med Bipin 22085 F20T12/D/22 30 7500 6500 76 975 848 1,2
24 23.78 Med Bipin 22997 F20T12/G 10 9000 1,2
22075 F20T12/D830 30 9000 3000 80 1350 1242 1,2
22252 F20T12/DWW/RP 69000 3000 70 1300 1170 1,2
22131 F20T12/WW 30 9000 3000 52 1250 1088 1,2
22134 F20T12/WW/RP 69000 3000 52 1250 1088 1,2
22251 F20T12/D35 30 9000 3500 70 1300 1170 1,2
22082 F20T12/CWX 30 9000 4100 87 890 774 1,2
22255 F20T12/D41 30 9000 4100 70 1300 1170 1,2
22256 F20T12/DCW/RP 69000 4100 76 1300 1170 1,2
22078 F20T12/CW 30 9000 4200 62 1200 1044 1,2
22015 F20T12/CW/RP 69000 4200 62 1200 1044 1,2
22073 F20T12/CW/UPC 30 9000 4200 62 1200 1044 1,2
22119 F20T12/DSGN50 30 9000 5000 90 880 766 1,2
22083 F20T12/D 30 9000 6500 76 1075 935 1,2
22087 F20T12/D/UPC 30 9000 6500 76 1075 935 1,2
25 T12 28 27.78 Med Bipin 22527 F25T12/CW/28 30 7500 4200 62 1670 1453 1,2
30 29.78 Med Bipin 22333 F25T12/WW/30 30 7500 3000 52 1750 1523 1,2
22528 F25T12/CW/30 30 7500 4200 62 1730 1505 1,2
33 32.78 Med Bipin 22529 F25T12/CW/33 30 7500 4200 62 1850 1610 1,2
22531 F25T12/D/33 30 7500 6500 76 1600 1392 1,2
F
L
U
O
R
E
S
C
E
N
T
T8 Med Bipin T12 Med Bipin T14 1/2 RDC
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
134
PREHEAT LAMPS
Standard T8 and T12 Preheat Lamps (Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
30 T8 36 35.78 Med Bipin 23140 F30T8/DWW/RP 67500 3000 70 2360 2124 1,2
23701 F30T8/WW 24 7500 3000 52 2150 1871 1,2
23182 F30T8/N 24 7500 3600 86 1500 1305 1,2
23127 F30T8/CWX 24 7500 4100 87 1550 1349 1,2
23121 F30T8/CW 67500 4200 62 2180 1897 1,2
23116 F30T8/CW 24 7500 4200 62 2180 1897 1,2
23100 F30T8/D 24 7500 6500 76 1850 1653 1,2
40 T12 48 47.2 Med Bipin 24409 L40W/30-1 25 3000 50 1,2,43,44,47
65 T8 Med Bipin 24736 L 65W/10 S 25 6000 75 1,2,8
70 T8 70 70 Med Bipin 20804 L70W / 21 - 840 25 15000 4000 80 6550 6026 1,2,8
SPECIALTY FLUORESCENT LAMPS
SAFELINE®Shatter Resistant Coated Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
32 T8 48 47.78 Med Bipin 21678 FO32/735/SL 30 20000 3500 75 2745 2470 1,2,20,
21,25,26
34 T12 48 47.78 Med Bipin 24396 F34CW/SS/SL 30 20000 4200 62 2600 2235 1,25,26,43,44,
formerly F40CW/SS/SL 45
Weather-Shielded Jacketed Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
70 T14.5 60 57.91 Recessed DC 21124 FJ60T12/CW/HO 812000 4200 62 5300 4293 1,2,8,51,61
110 T12 96 93.1 Recessed DC 21356 FJ96T12/CW/HO 812000 4200 62 8500 6885 1,2,8,51,61
128 T12 48 45.91 Recessed DC 21330 FJ48T12/CW/VHO/LT 12 10000 4200 62 6750 4725 1,2,8,54,56,61
165 T12 72 69.91 Recessed DC 21335 FJ72T12/CW/VHO/LT 810000 4200 62 10700 7490 1,2,8,54,56,61
215 T12 96 93.1 Recessed DC 21340 FJ96T12/CW/VHO/LT 810000 4200 62 15300 10710 1,2,8,54,56,61
GRO-LUX®Lamps for Plant Growth & Aquariams
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
15 T8 18 17.78 Med Bipin 21657 F15T8/GRO/AQ/RP 67500 66 325 1,2,8,62
20 T12 24 23.78 Med Bipin 22029 F20T12/GRO/AQ/RP 69000 480 1,2,8,62
22013 F20T12/GRO/AQ/WS/RP 69000 3400 89 750 1,2,8,62
30 T8 36 35.78 Med Bipin 23160 F30T8/GRO/AQ/RP 67500 66 800 1,2,8,62
40 T12 48 47.78 Med Bipin 24660 F40/GRO/AQ/RP 620000 1200 1,2,8,43,44,
46,47
24671 F40/GRO/AQ/WS/RP 620000 3400 89 1700 1,2,8,43,44,
46,47
F
L
U
O
R
E
S
C
E
N
T
T2 Axial Base Icetron
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
135
SPECIALTY FLUORESCENT LAMPS
Miniature T2 Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
6T2 8.6 8.6 Axial 26204 FM6/830 20 10000 3000 80 330 297 1,2,8,9,11,
63,64
26233 FM6/835 20 10000 3500 80 330 297 1,2,8,9,11,
63,64
26213 FM6/841 20 10000 4100 80 330 297 1,2,8,9,11,
63,64
8T2 12.6 12.6 Axial 26237 FM8/830 20 10000 3000 80 540 486 1,2,8,9,11,
63,64
26234 FM8/835 20 10000 3500 80 540 486 1,2,8,9,11,
63,64
26232 FM8/841 20 10000 4100 80 540 486 1,2,8,9,11,
63,64
11 T2 16.6 16.6 Axial 26239 FM11/830 20 10000 3000 80 750 675 1,2,8,9,11,
63,64
26235 FM11/835 20 10000 3000 80 750 675 1,2,8,9,11,
63,64
26231 FM11/841 20 10000 4100 80 750 675 1,2,8,9,11,
63,64
13 T2 20.6 20.6 Axial 26253 FM13/830 20 10000 3000 80 930 837 1,2,8,9,11,
63,64
26291 FM13/835 20 8000 3500 80 960 837 1,2,8,9,11,
63,64
26230 FM13/841 20 10000 4100 80 930 837 1,2,8,9,11,
63,64
ICETRON®Inductively Coupled, Electrodeless Lamps
The ICETRON®System is a unique adaptation of the inductively coupled electrodeless technology delivering high luminous efficacy, extremely long system life
of 100,000 hours in a shape uniquely suited for a variety of lighting applications. The ICETRON lamps and ballasts are designed as dedicated systems and are
not interchangeable with other lamps and ballasts. Please consult OSRAM SYLVANIA for fixture design and application assistance. An ICETRON Design Guide
is available on request.
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
70 T17 12.32 Mounting Bkts 26081 ICE70/835 1100000 3500 80 6200 4588 1,2,11,65,66,
67,68,69
26087 ICE70/835/2P/ECO 1100000 3500 80 6200 4588 1,2,6,
11,66,67,68,69
26082 ICE70/841 1100000 4100 80 6200 4588 1,2,11,65,66,
67,68,69
26088 ICE70/841/2P/ECO 1100000 4100 80 6200 4588 1,2,6,
11,66,67,68,69
26089 ICE70/850/2P/ECO 1100000 5000 80 5950 4588 1,2,6,
11,66,67,68,69
100 T17 12.32 Mounting Bkts 26100 ICE100/835 1100000 3500 80 8000 5920 1,2,11,65,66,
67,68,69
26102 ICE100/835/2P/ECO 1100000 3500 80 8000 5920 1,2,6,
11,66,67,68,69
26101 ICE100/841 1100000 4100 80 8000 5920 1,2,11,65,66,
67,68,69
26103 ICE100/841/2P/ECO 1100000 4100 80 8000 5920 1,2,6,
11,66,67,68,69
F
L
U
O
R
E
S
C
E
N
T
Icetron T12 Med Bipin T5 Mini Bipin T8 Med Bipin T12 RDC
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
136
SPECIALTY FLUORESCENT LAMPS
ICETRON®Inductively Coupled, Electrodeless Lamps
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
100 T17 12.32 Mounting Bkts 26105 ICE100/850/2P/ECO 1100000 5000 80 7600 5920 1,2,6,
11,66,67,68,69
150 T17 16.28 Mounting Bkts 26150 ICE150/835 1100000 3500 80 12000 8880 1,2,11,65,66,
67,68,69
26152 ICE150/835/2P/ECO 1100000 3500 80 12000 8880 1,2,6,
11,66,67,68,69
26151 ICE150/841 1100000 4100 80 12000 8880 1,2,11,65,66,
67,68,69
26153 ICE150/841/2P/ECO 1100000 4100 80 12000 8880 1,2,6,
11,66,67,68,69
26155 ICE150/850/2P/ECO 1100000 5000 80 11650 8880 1,2,6,
11,66,67,68,69
Diazo (SDB)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
65 T12 48 47.78 Med Bipin 24465 F40T12/SDB/65W 30 1000 86
Blacklight, Preheat Lamps (Starter Required)
These lamps are not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
6T5 9 8.91 Mini Bipin 20633 F6T5/350BL 24 7500 1,2,71,72,73
8T5 12 11.91 Mini Bipin 20833 F8T5/350BL 24 7500 1,2,71,72,74
15 T8 18 17.78 Med Bipin 21623 F15T8/350BL 24 7500 1,2,71,72,75
20 T12 24 23.78 Med Bipin 22113 F20T12/350BL 24 9000 1,2,71,72,76
22 T12 15 14.78 Med Bipin 21445 F15T12/350BL/500/PH 30 1,2,71,72,77
25 T8 18 17.78 Med Bipin 21703 F25T8/350BL/18in 24 1,2,71,72,78
30 T8 36 35.78 Med Bipin 23113 F30T8/350BL 24 7500 1,2,71,72,79
32 T12 18 17.78 Med Bipin 21525 F18T12/350BL/700/PH 30 1,2,71,72,80
Blacklight, Rapid Start Lamps (No Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
40 T12 48 47.78 Med Bipin 24922 F40/350BL 30 20000 1,2,43,44,46,47,
72,81
115 T12 48 45.91 Recessed DC 25251 FR48T12/350BL/VHO/180 30 10000 1,2,72,82,83
Blacklight Blue, Preheat Lamps (Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
4T5 6 5.91 Mini Bipin 20425 F4T5/BLB 24 6000 1,2,71,72
8T5 12 11.91 Mini Bipin 20825 F8T5/BLB 24 7500 1,2,71,72
15 T8 18 17.78 Med Bipin 21625 F15T8/BLB 67500 1,2,71,72,84
20 T12 24 23.78 Med Bipin 22116 F20T12/BLB/RP 69000 1,2,71,72,84
F
L
U
O
R
E
S
C
E
N
T
T12 Med Bipin T5 Mini Bipin T8 Med Bipin
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
137
SPECIALTY FLUORESCENT LAMPS
Blacklight Blue, Rapid Start Lamps (No Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
40 T12 48 47.78 Med Bipin 24026 F40/BLB/RP 620000 1,2,43,44,46,47,
72,85
Germicidal, Preheat Lamps (Starter Required)
41 Nominal Avg Approx Lumens
|
Nominal Length MOL Product Pkg Rated CCT Initial Mean Symbols &
|
Wattage Bulb (in) (in) Base Number Ordering Abbreviation Qty Life (hrs) (K) CRI @25°C/77°F Footnotes
|
8T5 12 11.91 Mini Bipin 20811 G8T5 24 6000 1,2,32,71,87
15 T8 18 17.78 Med Bipin 21612 G15T8 24 7500 1,2,32,71,87
30 T8 36 35.78 Med Bipin 23112 G30T8 24 7500 1,2,32,71,87
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 139-143
138
FLUORESCENT PREHEAT LAMP STARTERS
GLOSTAT Starters
47
|
Product Pkg Symbols &
|
Number Ordering Abbreviation Qty Description Footnotes
|
42812 FS-2 100 Fluorescent starter for use with F14, F15 and F20 preheat fluorescent lamps. UL, CSA
42901 FS-2/BL/2PK 12 Fluorescent starter for use with F14, F15 and F20 preheat fluorescent lamps, bulk pack with 2
starters. UL, CSA
44812 FS-4 100 Fluorescent starter for use with F13, F30 and F40 preheat lamps. UL, CSA
44820 FS-4 1000 Fluorescent starter for use with F13, F30 and F40 preheat lamps. UL, CSA
44900 FS-4/BL 100 Fluorescent starter for use with F13, F30 and F40 preheat lamps, blister pack. UL, CSA
44902 FS-4/BL/2PK 12 Fluorescent starter for use with F13, F30 and F40 preheat lamps, blister pack with 2 starters. UL,
CSA
45812 FS-5 100 Fluorescent starter for use with F4, F6 and F8 preheat fluorescent lamps. UL, CSA
45813 FS-5/BL/2PK 12 Fluorescent starter for use with F4, F6 and F8 preheat fluorescent lamps, blister pack with 2
starters. UL, CSA
43813 FS-12/BL/2PK 12 Fluorescent starter for use with FC12 Circline lamps when operated by preheat ballasts and F22T8
preheat lamps, blister pack with 2 starters. UL, CSA
42512 FS-25 100 Fluorescent starter for use with FC6 (20W) & FC8 (22W) Circline lamps when operated by preheat
ballasts; F25 and F18T8 preheat lamps. UL, CSA
42513 FS-25/BL/2PK 12 Fluorescent starter for use with FC6 (20W) & FC8 (22W) Circline lamps when operated by preheat
ballasts; F25 and F18T8 preheat lamps, blister pack with 2 starters. UL, CSA
44901 ST 111 STARTER 800 Fluorescent starter for use with 4, 6, 8, 10, 13, 15, 16, 18, 20, 22, 30, 32, 36, 38, 40, 58, 65,
80W preheat lamps; 18, 24 & 36W DULUX L lamps when operated by preheat ballasts. ENEC & VDE approved
44903 ST 151 STARTER 800 Fluorescent starter for series operation for use with 4, 6, 8, 15, 16, 18, 20, 22W preheat lamp; 18
& 24W DULUX L lamps when operated by preheat ballasts; ENEC & VDE approved
44910 ST 191 STARTER 800 Fluorescent starter for use with 100, 115 & 140W preheat lamps; ENEC & VDE approved
COP STARTERS WITH CUTOUT AND MANUAL RESET
47
|
Product Pkg Symbols &
|
Number Ordering Abbreviation Qty Description Footnotes
|
42302 FS-20 (COP-20) 100 Fluorescent starter with cutout and manual reset for use with F15 & F20 preheat lamps. UL, CSA
44102 FS-40/400 (COP-40/400)100 Fluorescent starter with cutout and manual reset for use with F40 preheat lamps. UL, CSA
HID STARTER
47
|
Product Pkg Symbols &
|
Number Ordering Abbreviation Qty Description Footnotes
|
44918 SE600 800 Replacement starter element (built-in spark gap type) for igniters used with Powerstar HQI metal
halide and Vialox HPS lamps. Replace each time lamp is replaced.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com 139
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
QUICK60+®warranty
Rating given for 200mA operation.
This fluorescent lamp generates radiant energy which is most beneficial for plant propagation and enhances vegetative and reproductive
growth of many plants for home and commercial use.
This lamp or ballast meets minimum Federal efficiency standards.
This ECOLOGIC®lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal reg-
ulations may vary; check local and state regulations.
This lamp is a High Color Rendering Lamp
Product is Canadian Standards Association approved for the Canadian market
Product is Underwriters Laboratories listed
Footnote Description
1Approximate initial lumens after 100 hours operation.
2The life ratings of fluorescent lamps are based on 3 hr. burning cycles under specified conditions and with ballast meeting ANSI specifica-
tions. If burning cycle is increased, there will be a corresponding increase in the average hours life.
3Rule of Thumb for Compact Fluorescent Lamps: Divide wattage of incandescent lamp by 4 to determine approximate wattage of compact flu-
orescent lamp that will provide similar light output.
4Minimum starting temperature: CF5: -22 degrees F; CF7: -4 degrees F; CF9: 14 degrees F; CF13DS: 14 degrees F; CF13DD: -4 degrees F;
CF18DD: 5 degrees F; CF18DT: -4 degrees F; CF26: 14 degrees F.
52 pin CF lamps should never be installed in 4 pin sockets regardless if lamp will fit.
6SYLVANIA ECOLOGIC®fluorescent lamps are designed to pass the Federal Toxic Characteristic Leaching Procedure (TCLP) criteria for classifi-
cation as non-hazardous waste in most states. TCLP test results are available upon request. Lamp disposal regulations may vary, check
your local & state regulations. For more information, please visit www.lamprecycle.org
7CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.2m (8 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
8Minimum starting temperature is a function of the ballast; consult the ballast manufacturer.
9There is a NEMA supported, industry issue where T2, T4, and T5 fluorescent and compact fluorescent lamps operated on high frequency bal-
lasts may experience an abnormal end-of-life phenomenon. This end-of-life phenomenon can result in one or both of the following: 1. Bulb
wall cracking near the lamp base. 2. The lamp can overheat in the base area and possibly melt the base and socket. NEMA recommends that
high frequency compact fluorescent ballasts have an end-of-life shutdown circuit which will safely and reliably shut down the system in the
rare event of an abnormal end-of-life failure mode described above. The final requirements of this system are yet to be defined by ANSI. For
additional information refer to NEMA papers on their WEBSITE at www.NEMA.org.
10 This 4-pin DULUX®lamp has an internal end-of-life mechanism (EOL) that shuts down the lamp preventing abnormal end-of life failure modes.
This lamp was designed for use with high frequency ballasts that do not have their own end-of-life (lamp) sensing circuits, but it is also com-
patible with high frequency ballasts that have their own end-of-life (lamp) sensing circuits.
11 Lumen output and life rated on high frequency operation.
12 Amalgam compact fluorescent lamps provide at least 90% light output from 40-140 degrees F. Non-amalgam compact fluorescent lamps
provide at least 90% light output from 60-100 degrees F in the base up position, the temperature range is narrower for horizontal or base
down.
13 These lamps may also be operated on rapid start circuits. On rapid start circuits the 24 watt lamp operates at 27 watts and the 36 watt lamp
operated at 39 watts. Rated lamp life is unchanged.
14 Lumen output rated on high frequency operation. 60 HZ operation would result in lower lumen output.
15 DULUX®F lamps can typically be operated on DULUX L and PENTRON®HO ballasts of the same/similar wattage. Check with the ballast manu-
facturer to verify lamp/ballast compatibility.
16 Minimum starting temperature for DULUX EL lamps is 0° F, unless otherwise specified in product literature.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
140
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote Description
17 DULUX®Els meet CSA, FCC and UL requirements.
18 Caution: DULUX EL units cannot be used on dimming circuits, emergency exit fixtures or lights, electronic timers, photocells or lighted
switches. In outdoor applications, use only in enclosed fixtures to avoid exposure to weather. Use only on 120V, 60 Hz circuits. Never dis-
assemble or modify lamp. Install or remove unit from fixture by grasping plastic base. Best performance achieved when operated at
77degrees F (25 degrees C).
19 Minimum starting temperature for EL Globes & Reflectors is -22 degrees F. Minimum starting temperature for EL Triples, Twists and Mini
Twists is 0 degrees F.
20 The life rating of OCTRON®and OCTRON Curvalume lamps operated on magnetic rapid start ballasts is 20,000 hours. The life rating of
OCTRON and OCTRON Curvalume lamps operated on instant start electronic ballasts is 15,000 hours.
21 OCTRON lamps should be operated only with magnetic rapid start ballasts designed to operate 265 mA, T8 lamps or high frequency (elec-
tronic) ballasts that are either instant start, or rapid start, or programmed rapid start specifically designed to operate T8 lamps. OCTRON
lamps may be operated on instant start ballasts with ballast factors ranging from a minimum of 0.71 to a maximum of 1.20 at the nominal
ballast input voltage. When OCTRON lamps are operated in the instant start mode, the two wires or two contacts of each socket should be
connected to each other. They should then be connected to the appropriate ballast lead wire using National Electric Code techniques.
22 Life rating of OCTRON XP
lamps operated on instant start electronic ballasts is 18,000 hours based on the industry standard life test cycle of
3 hours per start.
23 The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8,000
hours, 40% of 20,000 hours. It was used to allow comparison to standard OCTRON® lamps with an average rated life of 20,000 hours. The
lamp lumen maintenance factor at 40% of the 24,000 hour average rated life of this lamp, 9600 hours, would be 94%.
24 Gold OCTRON lamp has plastic tube guard which filters wavelengths less than 525nm and provides shatter protection.
25 SAFELINE®lamps satisfy the criteria of having a non-shattering covering for prevention of glass and other lamp components in your product
by containment within the safety coating material. The covering must be intact or the lamp must be replaced to be in compliance. An onsite
inspector will require correction if the lamps are installed improperly or not maintained properly.
26 SAFELINE lamps are intended for indoor use only. Lamps must be used in ambient temperatures below 135 degreed F. The coating is
designed to withstand constant operating temperatures up to 239 degrees F and has a melting point in excess of 500 degrees F. Lamps must
be used with sockets that provide adequate lamp pin to socket contact. Lamps must not be used with defective ballasts sockets, or fixtures
with improper wiring.
27 The lumen maintenance factor used to determine the mean lumens value was 90%, measured at 40% of the average rated life, 15,000 hours.
The lumen maintenance factor at 4,000-4,800 hours (for comparison to F96T12 HO and F96T12 Slimline instant start lamps) is 91%.
28 The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8000
hours, 40% of 20,000 hours. It was used for comparison to standard OCTRON® lamps with an average rated life of 20,000 hours. The lamp
lumen maintenance factor at 40% of 24,000 hours, 9600 hours, would be 94%; the lamp lumen maintenance factor at 40% of 30,000 hours,
12,000 hours, would be 93%
29 This lamp may also be operated by the OSRAM SYLVANIA QUICKTRONIC® PSN ballast (.88 BF), or the QUICTRONIC PSX ballast (.71 BF).
30 Recommended to be used on any F32 T8 Instant Start circuit. It is not recommended to be used:(1) with Rapid Start circuits unless the open
circuit voltage is greater than 550V, (2) at lamp ambient temperatures below 60 degrees F or in drafty locations, (3) on low power factor bal-
last, (4) dimming ballast or (5) inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use
with the OCTRON® SUPERSAVER® 28 or 30 watt, 4 foot or 30W U-bent T8 lamp. Any of the above situations could result in lamp starting
and stabilization problems.
31 The 30,000 hour average rated life of the FO32/800XPS/ECO OCTRON® lamp is based on operation at 3 hours per start on a dedicated
QUICKTRONIC® PSX ballast. If operated on other ballasts for T8 OCTRON lamps, lamp life will be 20,000 hours for rapid start operation,
24,000 hours for programmed rapid start operation and 15,000 hours for instant start operation at 3 hours per start.
32 Germicidal lamps can be operated on corresponding wattage preheat ballasts.
33 Mean lumens at 8,000 hours (40% of 20,000 hours for comparison to standard OCTRON and F40 rapid start lamps). The lumen mainte-
nance factor at 40% of average rated life (9,600 hours) is 94%.
34 Recommended to be used on any F96 T8 Instant Start circuit. It is not recommended to be used: (1) at lamp ambient temperatures below 60
degrees F or in drafty locations, (2) on low power factor ballast, or (3) inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with the OCTRON FO96 SUPERSAVER 55 watt T8 lamp. Any of the above situations could result in
lamp starting and stabilization problems.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com 141
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote Description
35 The lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 6000 hours,
40% of 15,000 hours. It was used to allow comparison to standard OCTRON® lamps with an average rated life of 15000 hours. The lamp
lumen maintenance factor at 40% of the 18,000 hour average rated life of this lamp, 7200 hours, would be 94%.
36 The lumen maintenance factor used to determine the mean lumens value was 92%, measured at 40% of the average rated life, 15,000 hours.
The lumen maintenance factor at 4,000-4,800 hours (for comparison to F96T12 HO and F96T12 Slimline instant start lamps) is 93%.
37 Approximate length of OCTRON CURVALUME lamps is measured from base face to outside of glass bend.
38 For optimum performance OCTRON CURVALUME 1 5/8 inch leg spacing lamps in the 3000K, 3500K and 4100K color temperatures are now
available only in the 82CRI version (800 series). These lamps are made to the same color standards and may be used in combination with
other SYLVANIA OCTRON lamps to meet the needs of lighting installations where T8 lamps are used.
39 The 30,000 hour average rated of the OCTRON®XPS CURVALUME®lamp is based on operation at 3 hours per start by a dedicated
QUICKTRONIC®PSX ballast. If operated by other ballasts for T8 OCTRON lamps, life will be the same as that of the XP version of the
lamp: typically 24,000 hours for rapid or programmed rapid start operation and 18,000 hours for instant start operation at 3 hours per start.
40 The lamp lumen maintenance factor used to determine the mean lumen value was 95%. This is the lamp lumen maintenance factor at 8,000
hours, 40% of 20,000 hours. It was used to allow comparison to standard OCTRON lamps with an average rated life of 20,000 hours.
The lamp lumen maintenance factor at 40% of 24,000 hours, 9600 hours, would be 94%; the lamp lumen maintenance factor at 40% of
30,000 hours, 12000 hours, would be 93%.
42 Recommended only for use on 2-lamp, 30 watt rapid-start high power factor lead, indoor ballasts that meet ANSI standards. Not intended
for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 25 watt lamps.
43 Average rated life is measured at 3 hours per start on 2-lamp, rapid start magnetic ballasts per IES recommended practice. Lamp life on sin-
gle-lamp rapid start ballasts may be reduced.
44 Average life rating at 12 hours operation per start is 28,800 hours.
45 Recommended for use on one or two lamp 40 watt rapid start, high power factor, lead, indoor ballasts that meet ANSI standards. Not intend-
ed for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced cur-
rent/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 34 watt lamps.
46 The "RS" designation has been eliminated to simplify the ordering abbreviation.
47 40W Rapid Start Lamps may be used in starter operated fixtures designed for 40W preheat lamps. Life rating for preheat service is approxi-
mately 15,000 hours average.
48 Rating for OSRAM SYLVANIA Circline lamps are based on operation in Rapid Start circuits. They will also operate on preheat circuits.
49 Caution: DULUX®EL Circline units cannot be used on dimming circuits, emergency exit fixtures or lights, electronic timers, photocells or light-
ed switches. In outdoor applications, use only in enclosed fixtures to avoid exposure to weather. Use only on 120V, 60 Hz circuits.
50 Recommended for use on one or two lamp high power factor, lead, 8-foot lamp, high output, indoor ballasts that meet ANSI standards. Not
intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 95 watt lamps.
51 Average life rating at 12 hours operation per start is 18,000 hours.
52 May be operated at 100 watts (1000MA) same as F84T12/HO.
53 Labeled for cold temperature (below 60 degrees F) operation only per EPACT.
54 Average life rating at 12 hours operation per start is 15,000 hours.
55 Low temperature performance rated at 35 degrees F ambient.
56 Low temperature performance rated at 35 degrees F ambient.
57 Cool White lamp with 30 degree aperture (Power Beam).
58 Recommended for use on 2-lamp high power factor, lead, 8-foot lamp, very high output, indoor ballasts that meet ANSI standards. Not
intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless equipment is
specifically listed for use with 195 watt lamps.
59 Recommended for use on one or two lamp high power factor, lead, instant-start, indoor ballasts that meet ANSI standards. Not intended for
use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced
current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above
equipment is specifically listed for use with 32 watt or 60 watt lamps.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com
142
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote Description
60 For operation on instant start circuits. Use only in fixtures equipped with Instant Start Ballasts.
61 A fluorescent jacketed lamp consists of a T12 (1 1/2" diameter) lamp enclosed inside a T14.5 (1 13/16" diameter) glass jacket. A jacketed
fluorescent lamp operates efficiently over a wide range of climatic conditions, including extremes of cold and strong wind in which an unjack-
eted (bare) lamp would be inefficient or inoperable. The jacket size provides the clearance necessary to minimize damaging lamp-jacket con-
tact; narrow bands of rubber placed between the lamp and the jacket further prevent contact. A weather-tight seal is formed by neoprene
rubber end caps.
62 Preheat lamp, starter required.
63 Due to their small diameter, T2 miniature fluorescent lamps operate at higher surface temperatures than other fluorescent lamps. To avoid
possible burns, do not touch the lamp during operation and allow sufficient cooling time before removing the lamp from the fixture. The typi-
cal bulb wall temperature during operation is 120 degrees at the ends. The maximum allowable bulb wall temperature is 150 degrees C. To
avoid electrical shock, turn electrical power off before removing or installing the lamp.
64 Use only with electronic ballasts which have been specifically designed to operate T2 miniature fluorescent lamps and to reliably and safely
control all lamp operating modes including end-of-lamp-life sensing circuitry. If a non-conforming ballast is used, very high temperatures
(350 degrees C typical) may be generated at the ends of the lamp especially during end-of-lamp-life operation, causing the lamp to crack and
resulting in potential fire, electrical shock, or burn hazards.
65 Current ballast design incorporates a modular 2-Pin connector plugin from the lamp. An adapter, NAED code 26240, is available to connect
3-Pin lamp types to current (2-Pin) design ballasts.
66 Color and CRI at amalgam tip temperature of 149 degrees F (65 degrees C) for ICETRON 70 and ICETRON 100 and at 158 degrees F (70
degrees C) amalgam tip temperature for ICETRON 150.
67 ICETRON diameter is the outside diameter of the ferrite coil. ICETRON MOL is the length from the outside edge of the mounting bracket on
one end to the outside edge of the mounting bracket on the opposite end.
68 WARNING: ICETRON®Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using
this lamp. 1. This lamp operates at a higher temperature (130 C) than standard fluorescent lamps. To avoid the possibility of minor skin
burns, do not touch lamp or metal mounting brackets during operation and allow sufficient cooling time prior to servicing, handling, or
replacing lamp. 2. This lamp generates electric and magnetic fields during operation. The electric and magnetic fields generated by this lamp
during operation in typical lighting applications do not pose exposure risks relative to the limits documented in ANSI C95.1. 3. To prevent
electric shock, shut off the main power to the fixture and allow at least two minutes for ballast voltage to discharge before attempting to serv-
ice or replace lamp. 4. To obtain optimum safety and system performance, use only with OSRAM SYLVANIA ballast. 5. To avoid potential
electric shock hazard, do not use lamp if wires or insulation are cut or pulled out of connector. 6. To avoid potential electric shock hazard, do
not use lamp if wires or insulation are cut or pulled out of connector.
69 WARNING: ICETRON®Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using
this lamp. Instructions for Installation and Use. 1. To avoid premature lamp or ballast failure and ensure proper lamp, ballast, and system
performance, make sure lamp, ballast, and fixture are properly installed. Electrical interconnects, electrical grounds, thermal management,
and heat sinking specifications and requirements must be fully adhered to in all applications. (See OSRAM SYLVANIA ICETRON DESIGN
GUIDE.) 2. Do not alter the electrical connector on lamp and/or ballast. To do so may adversely affect lamp operation, ballast life, and/or
emission of EMI (electromagnetic interference). 3. This product may cause interference with radios, cordless telephones, and remote control
devices. If interference occurs, relocate the radios, cordless telephones, and/or remote control devices away from this product.
70 The /2P version of the ICETRON lamp is supplied with a 24 inch lead wire terminated by a 2-Pin connector rather than the old 12 inch lead,
3-Pim connector design. The /2P versions are powered by QT1X100 ICE/UNV-T or QT1X150 ICE/UNV-T ballasts.
71 Starter required.
72 These lamps are not intended and should not be used for diagnostic, therapeutic, or cosmetic purposes.
73 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.35 meters (14 inches) should be limited; for example exposure at 0.25m (10 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
74 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.45 meters (18 inches) should be limited; for example exposure at 0.3m (12 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
75 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.55 meters (22 inches) should be limited; for example exposure at 0.4m (16 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com 143
SYMBOLS & FOOTNOTES FOR FLUORESCENT LAMPS
Footnote Description
76 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.65 meters (26 inches) should be limited; for example exposure at 0.45m (18 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
77 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.6 meters (24 inches) should be limited; for example exposure at 0.45m (18 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
78 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.7 meters (28 inches) should be limited; for example exposure at 0.54m (20 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
79 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.75 meters (30 inches) should be limited; for example exposure at 0.55m (22 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
80 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.8 meters (31 inches) should be limited; for example exposure at 0.55m (22 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
81 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
1.0 meters (39 inches) should be limited; for example exposure at 0.64m (24 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
82 Blacklight lamp with 180 degree reflector.
83 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 2 per ANSI/IESNA RP-27.3-96. Exposure at less than
2.0 meters (79 inches) should be limited; for example exposure at 1.4m (55 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
84 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.25 meters (10 inches) should be limited; for example exposure at 0.14m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
85 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.14m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
86 CAUTION: This lamp emits ultraviolet (UV) power during operation and is in Risk Group 1 per ANSI/IESNA RP-27.3-96. Exposure at less than
0.3 meters (12 inches) should be limited; for example exposure at 0.15m (6 inches) should not exceed 4 hours in an 8 hour interval (see
ANSI/IESNA RP-27.1-96). Certain medications and chemicals can increase an individual's sensitivity. Consult your physician for specific
information. Protective eyewear should be worn in occupational situations involving long term exposure in close proximity to the lamp. This
lamp is not intended and should not be used for diagnostic, therapeutic or cosmetic purposes.
87 WARNING: To prevent possible serious injury, eyes and skin should not be exposed to direct or reflected ultraviolet power emitted by this
lamp. This lamp is in Risk Group 3 per ANSI/IESNA RP-27.3-96. Adequate protection should be provided by clothing, gloves, opaque materi-
als, and ordinary window glass. Although this lamp will operate in standard fluorescent fixtures, it should not be used for general lighting
applications.
F
L
U
O
R
E
S
C
E
N
T
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
144
QUICKTRONIC®ELECTRONIC BALLASTS
THE SYSTEM SOLUTIONTM
OCTRON®T8 Systems
Instant Start
Normal Light Output 30 to 40% energy savings over F40T12 magnetic systems with comparable light output.
High Light output 20% more lumen output than F40T12 magnetic systems while saving nearly 20% in energy. 30% more
light output than standard T8 systems - fewer lamps/ballasts/fixtures required.
Low Power 77% ballast factor for reduced wattage applications. 15% energy savings over standard T8 systems and
30% over F34T12 magnetic systems.
Instant Start Professional - 30 to 40% energy savings over F40T12 magnetic systems with comparable light output.
Universal Voltage
High Efficiency Saves 6% over standard electronic T8 ballasts.
Programmed Rapid Start Professional Operates linear and U bend T8 lamps in applications where extended lamp life is required.
(PROStart®) Universal Voltage In short cycle applications, delivers over twice the number of start cycles as IS or RS Circuits
PSX T8 Universal Voltage Professional Extra low (0.71) ballast factor ballast combined with high lumen output OCTRON XPS®T8 lamps
(PROStart) delivers 15% energy savings over standard 700 series T8/88% BF systems with comparable light output
Dimming (HELIOS) Professional Operates linear and U-bend equivalent T8 lamps over a wide dimming range (100-5% and 100-10%
models). Controlled via standard 0-10V fluorescent dimmers Ideal for both energy management and
architectural applications.
Instant Start 8 Foot T8
Normal Light Output Over 30% energy savings when compared to F96T12 magnetic systems.
High Light Output 30% more light output than standard T8 systems and 20% more than F96T12 systems.
Instant Start 8 foot T8 Professional Over 30% energy savings when compared to F96T12 magnetic systems
SLIMLINE T12 and T12HO Systems
T12 Rapid Start and 15% energy savings over standard magnetic systems
T12HO Rapid Start 8 foot
T12 Instant Start 8 foot 88% Ballast Factor for most standard applications. Operates silently and provides energy savings of
10 to 15%
PENTRON®T5 Systems (PROStart) Contains QUICKSENSE®end-of-lamp-life sensing technology
T5 Programmed Rapid Start Professional Over 10% more lumen output than T8 systems at comparable power levels. New benchmark for 2-lamp
system efficacy of 92 LPW.
T5HO Programmed Rapid Start Professional Provides nearly twice the light output (188%) of T8 systems.
T5HO Dimming (HELIOS) Professional Provides nearly twice the light output (188%) of T8 systems. Operates PENTRON®HO, PENTRON HO
Circline and DULUX®L T5 lamps over a wide (100-1%) dimming range.
Compact Fluorescent TT5 Systems Contains QUICKSENSE end-of-lamp-life sensing technology
TT5 Instant Start Over 30% more lumen output than 34T12 systems at nearly the same input power.
TT5 Programmed Rapid Start Over 20% more lumen output than 34T12 systems.
Professional (PROStart)
Compact Fluorescent T4 Systems (PROStart) Contains QUICKSENSE end-of-lamp-life sensing technology
Universal Voltage Four mounting styles of low profile, lightweight enclosures provide simple assembly for any
fixture application.
Fluorescent Miniature T2 Systems Small diameter lamp and low profile ballast create new design opportunities. Contains end-of-lamp-life
sensing technology.
ICETRON®Systems Longest life available from a fluorescent system in the market today. Lamp can last 100,000 hours, reduc-
ing maintenance costs and extending relamping cycles.
Electronic Metal Halide Systems Small and light weight. Electronic design delivers performance levels unattainable with standard mag-
netic systems, including up to 15% energy savings.
NOTE: For LED power supplies and modules, go to the LED Systems section.
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
145
HOW TO READ PRODUCT INFORMATION - ELECTRONIC BALLASTS
Primary No Input Input Input
|
Lamp of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32T8 2 120 49913 QT2X32T8/120ISN-SC 10 0.90 59 0.51 Leads 1,2,3,4
FO32T8 2 277 49914 QT2X32T8/277ISN-SC 10 0.90 59 0.22 Leads 1,2,3,4
Dimensions Go to www.sylvania.com
Wiring Diagram Go to www.sylvania.com
Wiring Method Indicates if product has lead wires or wiretrap connectors
HOW TO READ ORDERING ABBREVIATIONS
QT2X32T8/120ISN-SC QTP3X32T8/UNV ISN-SC QTP2X32T8/UNVPSN-SC
QT QT - QUICKTRONIC®QTP QTP - QUICKTRONIC Professional QTP QTP - QUICKTRONIC Professional
2x Number of lamps the ballast operates Series <10%THD Series <10%THD
32T8 Lamp wattage or length 3x Number of lamps the ballast operates 2x Number of lamps the ballast operates
120 Input voltage 32 Lamp wattage or length 32 Lamp wattage or length
ISN Starting Method/Ballast Factor T8 Lamp type T8 Lamp type
SC Case Size UNV Input voltage (120-277V) UNV Input voltage (120-277V)
IS Starting Method PS Starting method
NBallast Factor NBallast factor
SC Case Size SC Case size
BALLAST CATEGORIES
QUICKTRONIC SYLVANIA QUICKTRONIC electronic ballasts feature high power quality (<20% THD).
QUICKTRONIC SYLVANIA QUICKTRONIC Professional Series (QTP) of electronic ballasts feature high power quality.
Professional Series (<10% THD), lightweight, low profile designs.
Number of lamps the 1x, 1/2x, 2x, 3x, 4x.
ballast operates
Lamp type T8, T12, T12HO, T5, T5HO, TT5 & DL - DULUX®L, CF - T4 Compact Fluorescent, FM - T2 Fluorescent Miniature, ICE -
ICETRON®, MH - Metal Halide.
Input voltage 120, 230, 277, 347, UNV - Universal 120-277.
Starting Method IS - Instant start, PS - Programmed Rapid Start, DIM - Dimming, RS - Rapid Start.
Ballast Factor N - Normal Ballast Factor(0.85-1.00), L - Low Ballast Factor(0.75-0.80), H - High Ballast Factor(1.13-1.20), X - Very Low Ballast
Factor(0.71), PLUS - High Ballast Factor(1.15-1.20), LP - Low Ballast Factor(0.77).
Case Size Go to www.sylvania.com
Packaging configuration Distributor Pack.
Leads vs Connectors Go to www.sylvania.com
For more information about Electronic ballast warranties, please visit the warranty section of this catalog or go to:
www.sylvania.com/business/ballast/warranty.htm
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
146
T8 FLUORESCENT
T8 INSTANT START, <20%THD
Normal Light Output
Operates FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32, FO40 & SUPERSAVER®Equivalents; For F40T8 operation use 1 lamp on a 2 lamp ballast, 2 lamps
on a 3 lamp ballast or 3 lamps on a 4 lamp ballast
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 1 120 49911 QT1X32T8120ISNSC 10 0.90 30 0.26 Leads 1,2,4,6,7,8,
9,10,11,12,13
277 49912 QT1X32T8277ISNSC 10 0.90 30 0.11 Leads 1,2,4,6,7,8,
9,10,11,12,13
2120 49913 QT2X32T8120ISNSC 10 0.90 59 0.51 Leads 1,2,4,5,6,
7,8,9,10,11,12,13
277 49914 QT2X32T8277ISNSC 10 0.90 59 0.22 Leads 1,2,4,5,6,
7,8,9,10,11,12,13
347 49240 QT2X32T8347ISNSC 10 0.90 59 0.18 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
3120 49915 QT3X32T8/120-ISN-SC 10 0.89 87 0.74 Leads 1,2,5,6,7,8,
9,10,11,12,13
277 49916 QT3X32T8/277-ISN-SC 10 0.89 87 0.32 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
347 49593 QT3X32/347IS 10 0.90 87 0.26 Leads 1,2,4,5,6,7,8,9,
10,11,12,13
4120 49917 QT4X32T8/120-ISN-SC 10 0.89 114 0.95 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
277 49918 QT4X32T8/277-ISN-SC 10 0.89 114 0.42 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
347 49594 QT4X32/347IS 10 0.90 114 0.34 Leads 1,2,4,5,6,7,8,9,
10,11,12,13
High Light Output
Operates FBO31, FO32, FBO32 & SUPERSAVER®Equivalents
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 2 120 49923 QT2X32T8/120-ISH-SC 10 1.20 78 0.67 Leads 1,2,4,6,7,
8,9,10,11,12,13
277 49924 QT2X32T8/277-ISH-SC 10 1.20 78 0.29 Leads 1,2,4,6,7,
8,9,10,11,12,13
347 49226 QT2X32/347PLUS 10 1.20 78 0.23 Leads 1,2,4,6,7,8,
9,10,11,12,13
3120 49525 QT3X32/120PLUS 10 1.18 112 0.96 Leads 1,2,4,6,7,8,
9,10,11,12,13
277 49526 QT3X32/277PLUS 10 1.18 112 0.42 Leads 1,2,4,6,7,8,
9,10,11,12,13
4277 49521 QHE4X32T8277ISH 10 1.15 148 0.53 Leads 1,2,4,6,7,8,
9,10,11,12,13
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
147
T8 FLUORESCENT
T8 INSTANT START, <10%THD
High Light Output, Universal Voltage
Operates FBO31, FO32, FBO32 & SUPERSAVER®Equivalents
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 3 Universal 49845 QTP3X32T8UNVISHSC 10 1.18 114/111 0.95/0.41 Leads 1,2,4,6,7,8,
120-277 9,10
T8 INSTANT START, <20%THD
Low Power Systems
Operates FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32, FO40 & SUPERSAVER®Equivalents; For F40T8 operation use 1 lamp on a 2 lamp ballast, 2 lamps
on a 3 lamp ballast or 3 lamps on a 4 lamp ballast
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 1 120 49931 QT1X32T8/120-ISL-SC 10 0.77 28 0.24 Leads 1,2,4,6,7,
8,9,10,11,12,13
277 49932 QT1X32T8/277-ISL-SC 10 0.77 26 0.10 Leads 1,2,4,6,7,
8,9,10,11,12,13
2120 49933 QT2X32T8/120-ISL-SC 10 0.77 51 0.44 Leads 1,2,4,5,6,
7,8,9,10,11,12,13
277 49934 QT2X32T8/277-ISL-SC 10 0.77 51 0.19 Leads 1,2,4,5,6,
7,8,9,10,11,12,13
347 49241 QT2X32T8347ISLSC 10 0.77 51 0.15 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
3120 49935 QT3X32T8/120-ISL-SC 10 0.77 76 0.66 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
277 49936 QT3X32T8/277-ISL-SC 10 0.77 76 0.29 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
4120 49537 QT4X32/120LP 10 0.77 98 0.84 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
277 49538 QT4X32/277LP 10 0.77 98 0.37 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
347 49225 QT4X32/347LP 10 0.77 98 0.29 Leads 1,2,4,5,6,7,8,9,
10,11,12,13
T8 INSTANT START, <10%THD
Universal Voltage
Operates FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32, FO40 & SUPERSAVER®Equivalents; For F40T8 operation use 1 lamp on a 2 lamp ballast, 2 lamps
on a 3 lamp ballast or 3 lamps on a 4 lamp ballast
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 1 Universal 49941 QTP1X32T8/UNV-ISN-SC 10 0.88 30 0.26/0.11 Leads 1,2,4,6,7,8,
120-277 9,11,12,13,17
2Universal 49943 QTP2X32T8/UNV-ISN-SC 10 0.88 59 0.50/0.21 Leads 1,2,4,5,6,
120-277 7,8,9,11,12,17
3Universal 49945 QTP3X32T8/UNV-ISN-SC 10 0.88 87 0.75/0.32 Leads 1,2,4,5,6,7,
120-277 8,9,11,12
4Universal 49947 QTP4X32T8/UNV-ISN-SC 10 0.88 114 0.95/0.40 Leads 1,2,4,5,6,7,
120-277 8,9,11,12,24
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
148
T8 FLUORESCENT
HIGH EFFICIENCY, <10%THD
Instant Start
ISN, ISL: Operates FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32 & SUPERSAVER®Equivalents
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 1 Universal 49851 QHE1X32T8UNVISNSC 10 0.88 28 0.25/0.11 Leads 1,2,4,5,6,7,
120-277 8,9,11,12,17
2Universal 49853 QHE2X32T8UNVISNSC 10 0.88 55 0.47/0.20 Leads 1,2,4,5,6,
120-277 7,8,9,11,12,17
3Universal 49855 QHE3X32T8UNVISNSC 10 0.88 83/82 0.69/0.30 Leads 1,2,4,5,6,7,
120-277 8,9,11,12,17
4Universal 49857 QHE4X32T8UNVISNSC 10 0.88 108/107 0.91/0.39 Leads 1,2,4,5,6,7,
120-277 8,9,11,12,17
2Universal 49863 QHE2X32T8UNVISLSC 10 0.78 48 0.41/0.18 Leads 1,2,4,5,6,
120-277 7,8,9,11,12,17
4Universal 49867 QHE4X32T8UNVISLSC 10 0.78 95 0.80/0.35 Leads 1,2,4,5,6,7,
120-277 8,9,11,12,17
T8 PROGRAMMED START, <10%THD
Universal Voltage Xtreme System Low Ballast Factor
Operates FBO24, FO25, FBO31, FO32, FBO32
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XPS 1 Universal 51420 QTP1X32T8/UNVPSX TC 10 0.71 25 0.21/0.09 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
2Universal 51425 QTP2X32T8/UNVPSX TC 10 0.71 47/46 0.40/0.17 Leads 2,4,6,8,9,
120-277 10,11,12,17,75
3Universal 51430 QTP3X32T8/UNVPSX SC 10 0.71 73/71 0.59/0.25 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
4Universal 51435 QTP4X32T8/UNVPSX SC 10 0.71 93/91 0.78/0.33 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
Universal Voltage SUPERSAVER® Xtreme System Low Ballast Factor
Operates FO30WSS & FO28WSS Lamps
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO30/SS 1 Universal 51420 QTP1X32T8/UNVPSX TC 10 0.71 24 0.21/0.09 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
FO28/SS 1 Universal 51420 QTP1X32T8/UNVPSX TC 10 0.71 22 0.19/0.09 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
FO30/SS 2 Universal 51425 QTP2X32T8/UNVPSX TC 10 0.71 44/43 0.37/0.16 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
FO28/SS 2 Universal 51425 QTP2X32T8/UNVPSX TC 10 0.71 41/40 0.35/0.15 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
FO30/SS 3 Universal 51430 QTP3X32T8/UNVPSX SC 10 0.71 69/67 0.58/0.24 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
FO28/SS 3 Universal 51430 QTP3X32T8/UNVPSX SC 10 0.71 64/62 0.55/0.23 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
FO30/SS 4 Universal 51435 QTP4X32T8/UNVPSX SC 10 0.71 88/86 0.74/0.31 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
FO28/SS 4 Universal 51435 QTP4X32T8/UNVPSX SC 10 0.71 82/80 0.70/0.30 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
149
T8 FLUORESCENT
T8 PROGRAMMED START, <10%THD
Universal Voltage Normal Light Output
Operates FBO16, FO17, FBO24, FO25, FBO31, FO32, FBO32, & SUPERSAVER®Equivalents
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO32/XP 1 Universal 51400 QTP1X32T8/UNVPSNTC 10 0.88 31/30 0.26/0.11 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
2Universal 51405 QTP2X32T8/UNVPSN TC 10 0.88 60/58 0.50/0.21 Leads 2,4,6,8,9,10,
120-277 11,12,17,75
3Universal 51410 QTP3X32T8/UNVPSNSC 10 0.88 88/85 0.74/0.31 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
4Universal 51415 QTP4X32T8/UNVPSNSC 10 0.88 118/113 0.99/0.41 Leads 2,4,6,8,9,10,11,
120-277 12,17,75
T8 INSTANT START, <20%THD, 8 FOOT
Normal Light Output
Operates FO96T8 & SUPERSAVER®Equivalents
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO96T8 2 120 49581 QT2X59/120IS 10 0.88 110 0.95 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
277 49582 QT2X59/277IS 10 0.88 110 0.41 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
347 49217 QT2X59/347IS 10 0.88 110 0.33 Leads 1,2,4,5,6,7,8,9,
10,11,12,13
High Light Output
Operates FO96T8 & SUPERSAVER®Equivalents
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO96T8 120 49583 QT2X59/120PLUS 61.19 151 1.30 Leads 1,2,6,7,8,9,
10,11,12,13
277 49584 QT2X59/277PLUS 61.19 151 0.56 Leads 1,2,6,7,8,9,
10,11,12,13
T8 INSTANT START, <10%THD, 8 FOOT
Operates FO96T8 & SUPERSAVER®Equivalents
Normal Light Output - Universal Voltage
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FO96T8 2 Universal 49598 QTP2x59T8/UNV-ISN-SC 20 0.88 112/110 0.93/0.40 Leads 1,2,4,6,8,9,
120-277 10,11,12,13
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
150
T5 LINEAR FLUORESCENT
T5HO PROGRAMMED START, <10%THD
QTP1X54T5HOUNV PSN and QTP2X54T5HOUNV PSN operates FP54T5HO, FT55DL, FPC55; QTP1X3924T5HOUNV PSN and QPT2X3924T5HOUNV PSN oper-
ates FPC22, FT24DL, CF24DF, FP24T5HO, FT36DL, CF36DF, FPC40, FP39T5HO; QTP1X80T5HOUNV PSN operates FP80T5HO and FT80T5DL
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FP24T5HO 1 Universal 49100 QTP1X3924T5HOUNVPSN 10 1 29 0.23/0.10 Leads 1,2,4,6,8,9,
120-277 10,11,12,17,23
FP39T5HO 1 Universal 49100 QTP1X3924T5HOUNVPSN 10 1 42 0.36/0.15 Leads 1,2,4,6,8,9,
120-277 10,11,12,17,23
FP24T5HO 1 Universal 49101 QTP1X3924T5HOUNVPSN NL 20 1 29 0.23/0.10 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
FP39T5HO 1 Universal 49101 QTP1X3924T5HOUNVPSN NL 20 1 42 0.36/0.15 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
FP54T5HO 1 Universal 49120 QTP1X54T5HOUNVPSN 10 1 62/60 0.51/0.21 Leads 1,2,4,6,8,9,
120-277 10,11,12,17,23
49121 QTP1X54T5HOUNVPSN NL 20 1 62/60 0.51/0.21 Wiretrap 1,2,4,6,8,9,
Connectors 10,11,12,17,23
FP80T5HO 1 Universal 49151 QTP1X80T5HOUNVPSN NL 20 1 90 0.74/0.32 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
FP24T5HO 2 Universal 49110 QTP2X3924T5HOUNVPSN 10 1 55/54 0.47/0.20 Leads 1,2,4,6,8,9,
120-277 10,11,12,17,23
FP39T5HO 2 Universal 49110 QTP2X3924T5HOUNVPSN 10 1 85/83 0.76/0.32 Leads 1,2,4,6,8,9,
120-277 10,11,12,17,23
FP24T5HO 2 Universal 49111 QTP2X3924T5HOUNVPSN NL 20 1 55/54 0.47/0.20 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
FP39T5HO 2 Universal 49111 QTP2X3924T5HOUNVPSN NL 20 1 85/83 0.76/0.32 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
FP54T5HO 2 Universal 49130 QTP2X54T5HOUNVPSN 10 1 121/118 1.00/0.43 Leads 1,2,4,6,8,9,
120-277 10,11,12,17,23
49131 QTP2X54T5HOUNVPSN NL 20 1 121/118 1.00/0.43 Wiretrap 1,2,4,6,8,9,
Connectors 10,11,12,17,23
T5 PROGRAMMED START, <10% THD
Universal Voltage
Operates FP14, FP21, FP28, FP35
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FP28T5 1 Universal 49171 QTP1x28T5UNVPSN NL 20 1.00 32 0.28/0.12 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
2Universal 49181 QTP2X28T5UNVPSN NL 20 1.00 65/63 0.55/0.23 Wiretrap 1,2,4,6,8,9,
120-277 Connectors 10,11,12,17,23
T5HO PROGRAMMED START, <10%THD
Discrete Voltage
QTP1x80T5HOPSN operates FP80T5HO
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FP80T5HO 1 120 49660 QTP1x80T5HO/120PSN-E 20 1.00 91 0.75 Wiretrap 2,4,6,8,9,10,
Connectors 11,12,13,16
277 49670 QTP1x80T5HO/277PSN-E 20 1.00 90 0.33 Wiretrap 2,4,6,8,9,10,
Connectors 11,12,13,16
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
151 R1
TT5 COMPACT FLUORESCENT
TT5 INSTANT START, <20%THD
Operates FT40DL
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FT40DL 1 120 49641 QT1X40/120DL 10 0.96 40 0.33 Leads 1,2,4,5,6,7,
277 49642 QT1X40/277DL 0.14 8,9,10,11,12,13
2120 49643 QT2X40/120DL 10 0.96 75 0.63 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
277 49644 QT2X40/277DL 10 0.96 75 0.28 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
3120 49645 QT3X40/120DL 10 0.96 110 0.94 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
277 49646 QT3X40/277DL 10 0.96 110 0.42 Leads 1,2,4,5,6,7,
8,9,10,11,12,13
TT5 PROGRAMMED START, <10%THD
Normal Light Output
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FT40DL 1 120 50320 QTP1X40TT5/120PSN F 20 0.88 38 0.32 Leads 2,4,6,8,9,10,
11,12,13,16
277 50330 QTP1X40TT5/277PSN F 20 0.88 37 0.13 Leads 2,4,6,8,9,10,
11,12,13,16
2120 50340 QTP2X40TT5/120PSN F 20 0.88 76 0.63 Leads 2,4,6,8,9,10,
11,12,13,16
277 50350 QTP2X40TT5/277PSN F 20 0.88 73 0.27 Leads 2,4,6,8,9,10,
11,12,13,16
3120 50360 QTP3X40TT5/120PSN B 20 0.88 110 0.92 Leads 2,4,6,8,9,10,
11,12,13,16
277 50370 QTP3X40TT5/277PSN B 20 0.88 108 0.39 Leads 2,4,6,8,9,10,
11,12,13,16
T4 COMPACT FLUORESCENT
PROGRAMMED START UNIVERSAL VOLTAGE <10% THD
99 Primary Input Input
|
Product Pkg Lamp No. of Ballast Voltage Wattage Circuit Wiring Symbols &
|
Number Ordering Abbreviation Qty Type Lamps Factor (VAC) (W) Type Method Footnotes
|
51718 QTP 1/2X13CF/UNV BS 20 1 1.0 Universal 16 Series Wiretrap 8,9,10,11,17,25,28
51778 QTP 1/2X13CF/UNV QS 16 13W DD/E,T/E 2 1.0 120-277 29 Connectors
51748 QTP 1/2X13CF/UNV TS 20
51723 QTP 1/2X18CF/UNV BS 20 1 1.0 Universal 20 Series Wiretrap 8,9,10,11,17,25,28
51783 QTP 1/2X18CF/UNV QS 16 18W DD/E,T/E 2 1.0 120-277 38 Connectors
51753 QTP 1/2X18CF/UNV TS 20
51733 QTP 2X26CF/UNV BS 20 26W DD/E, T/E 1 1.0 Universal 28 Series Wiretrap 8,9,10,11,17,25,28
51793 QTP 2X26CF/UNV QS 16 26W DD/E, T/E 2 1.0 120-277 54 Connectors
51763 QTP 2X26CF/UNV TS 20 32W DT/E 1 0.98 35
42W DT/E 1 1.0 45
Note: QTPx26CF/UNV models now also operate one lamp as shown above
51738 QTP 1/2XCF/UNV BM 20 26W DD/E, T/E 1 1.02 Universal 28 Series Wiretrap 6,8,9,10,11,17,25,28
51798 QTP 1/2XCF/UNV PM 18 26W DD/E, T/E 2 1.02 120-277 57 Connectors
51768 QTP 1/2XCF/UNV TM 18 32W DT/E 1 0.97 36
42W DT/E 1 1.0 46
51743 QTP 2X26/32/42CF/UNV BM 20 26W DT/E 2 1.02 Universal 54 Series Wiretrap 6,8,9,10,11,17,25,28,
51803 QTP 2X26/32/42CF/UNV PM 18 32W DT/E 2 0.96 120-277 69 Connectors
51773 QTP 2X26/32/42CF/UNV TM 18 42W DT/E 2 0.95 94
51740 QT 1X57CF/UNV BM 20 57W DT/E 1 1 Universal 62 Series Wiretrap 6,8,9,10,11,17,25,28
51800 QT 1X57CF/UNV PM 18 70W DT/E 1 0.92 120-277 71 Connectors
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
152
T8 FLUORESCENT
T8 DIMMING, <10%THD
0-10V
Operates FBO31, FO32, FBO32
Primary38 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Control Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Setting Method Footnotes
|
FO32/XP 1 120 50700 QTP1X32T8/120DIM5 B 20 0.94 32 0.27 100%-5% Leads 2,4,6,8,9,10,
11,13,29,30,31
277 50710 QTP1X32T8/277DIM5 B 20 0.94 32 0.12 100%-5% Leads 2,4,6,8,9,10,
11,13,29,30,31
2120 50720 QTP2X32T8/120DIM5 B 20 0.94 66 0.57 100%-5% Leads 2,4,6,8,9,10,
11,13,29,30,31
277 50730 QTP2X32T8/277DIM5 B 20 0.94 66 0.25 100%-5% Leads 2,4,6,8,9,10,
11,13,29,30,31
3120 50750 QTP3X32T8/120DIM5-Q 20 0.88 93 0.78 100%-5% Leads 2,4,6,8,9,10,
11,13,29,30,31
277 50760 QTP3X32T8/277DIM5-Q 20 0.88 93 0.34 100%-5% Leads 2,4,6,8,9,10,
11,13,29,30,31
4120 50770 QTP4X32T8/120DIM10 Q 20 0.88 120 1.10 100%-10% Leads 2,4,6,8,9,10,
11,13,29,30,31
277 50780 QTP4X32T8/277DIM10 Q 20 0.88 120 0.55 100%-10% Leads 2,4,6,8,9,10,
11,13,29,30,31
T5 LINEAR FLUORESCENT
T5HO DIMMING, <10% THD
0-10V
Operates FP54T5HO
Primary38 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Control Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Setting Method Footnotes
|
FP54T5HO 1 120 49671 QT1X54/120PHO-DIM 20 1.00 62 0.54 100-1% Wiretrap 2,4,6,8,9,10,
Connectors 11,13,29,31,32
277 49672 QT1X54/277PHO-DIM 20 1.00 61 0.23 100-1% Wiretrap 2,4,6,8,9,10,
Connectors 11,13,29,31,32
2120 49673 QT2X54/120PHO-DIM 20 1.00 120 1.07 100-1% Wiretrap 2,4,6,8,9,10,
Connectors 11,13,29,31,32
277 49674 QT2X54/277PHO-DIM 20 1.00 117 0.45 100-1% Wiretrap 2,4,6,8,9,10,
Connectors 11,13,29,31,32
T8 FLUORESCENT
T8 DIMMING, <10%THD
DALI
Operates FBO31, FO32, FBO32
Primary38 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Control Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Setting Method Footnotes
|
FO32/XP 1 Universal 51350 QTP1X32T8/UNV DALI 25 1.00 36 0.31/0.13 100% - 1% Wiretrap 8,9,10,11,17,24,31,32
120-277
2Universal 51352 QTP2X32T8/UNV DALI 25 1.00 72/70 0.61/0.26 100% - 1% Wiretrap 8,9,10,11,17,24,31,32
120-277
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
153
T5 LINEAR FLUORESCENT
T5HO DIMMING, <10%THD
DALI
Operates FP54T5HO
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FP54T5HO 1 Universal 51364 QTP1X54T5HO/UNV DALI 25 1.00 62/61 0.52/0.22 Wiretrap 8,9,10,11,17,24,31,32
120-277 Connectors
2Universal 51366 QTP2X54T5HO/UNV DALI 25 1.00 122/119 1.05/0.44 Wiretrap 8,9,10,11,17,24,31,32
120-277 Connectors
T5 DIMMING, <10%THD
DALI
Operates FP28T5
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FP28T5 1 Universal 51356 QTP1X28T5/UNV DALI 25 1.00 32 0.27/0.11 Wiretrap 8,9,10,11,17,24,31,32
120-277 Connectors
2Universal 51358 QTP2X28T5/UNV DALI 25 1.00 64/62 0.55/0.23 Wiretrap 8,9,10,11,17,24,31,32
120-277 Connectors
T12 FLUORESCENT
T12 INSTANT START, <20%THD, 8 FOOT
Normal Light Output
Operates F60T12, F72T12, F84T12, F96T12, F96T12/SS
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
F96T12 2 120 49881 QT2X96/120IS 10 0.88 135 1.20 Leads 2,4,5,6,7,
9,10,11,13,16,32,63
277 49882 QT2X96/277IS 10 0.88 135 0.52 Leads 2,4,5,6,7,
9,10,11,13,16,32,63
T12HO RAPID START, <20%THD, 8 FOOT
Operates F48T12/HO, F60T12/HO, F72T12HO, F84T12/HO, F96T12HO, F96T12/HO/SS
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
F96T12/HO 2 120 49883 QT2X96/120HO 10 0.88 210 1.79 Leads 2,4,5,6,7,
9,10,11,13,16,48,63
277 49884 QT2X96/277HO 10 0.88 210 0.78 Leads 2,4,5,6,7,
9,10,11,13,16,48,63
T12 RAPID START, <10%THD
Operates F40T12
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
F40T12 1 120 50560 QTP1X40T12/120RSN B 20 0.875 38 0.34 Leads 2,4,6,8,9,10,
11,13,32,34
277 50570 QTP1X40T12/277RSN B 20 0.875 38 0.14 Leads 2,4,6,8,9,10,
11,13,32,34
2120 50580 QTP2X40T12/120RSN B 20 0.84 69 0.68 Leads 2,4,6,8,9,10,
11,13,32,34
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
154
T12 FLUORESCENT
T12 RAPID START, <10%THD
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
F40T12 2 277 50590 QTP2X40T12/277RSN B 20 0.835 68 0.27 Leads 2,4,6,8,9,10,
11,13,32,34
3120 50600 QTP3X40T12/120RSN B 20 0.875 109 0.92 Leads 2,4,6,8,9,10,
11,13,32,34
277 50610 QTP3X40T12/277RSN B 20 0.865 105 0.45 Leads 2,4,6,8,9,10,
11,13,32,34
ICETRON® UNIVERSAL VOLTAGE
QT1x100ICE/UNV operates ICE70, ICE100; QT1x150ICE/UNV operates ICE100, ICE150
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
ICE70 1 Universal 49753 QT1X100ICE/UNV-T 51.05 79/77 0.66/0.29 Connectors 4,6,8,9,10,11,
120-277 17,20,63,72,76,77,78
ICE100 1 Universal 49753 QT1X100ICE/UNV-T 51.00 106/103 0.88/0.37 Connectors 4,6,8,9,10,11,
120-277 17,20,63,72,76,77
49772 QT1X150ICE/UNV-T 51.38 154/149 1.28/0.54 Connectors 2,4,6,8,9,10,
11,17,20,63,72,77
ICE150 1 Universal 49772 QT1X150ICE/UNV-T 51.00 161/156 1.34/0.58 Connectors 2,4,6,8,9,10,
120-277 11,17,20,63,72,77
METAL HALIDE
UNIVERSAL VOLTAGE
QTP1x39MH/UNV operates (M130) PAR20, PAR30, T-6; QTP1x70MH/UNV operates (M143/M98) PAR30, PAR38, ED-17, (M139) T-6; QTP1x100MH/UNV oper-
ates (M140/M90) PAR38, ED-17
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
39W T6 1 Universal 51940 QTP 1X39MH/UNV F 10 1.00 45 0.38/0.16 Leads 4,6,8,9,10,11,
120-277 17,25,27,37,38,39
51941 QTP 1X39MH/UNV J 10 1.00 45 0.38/0.16 Leads 4,6,8,9,10,11,
17,25,27,37,38,39
70W T6 1 Universal 51942 QTP 1X70MH/UNV F 10 1.00 80 0.68/0.29 Leads 4,6,8,9,10,11,
120-277 17,25,27,37,38,39
51943 QTP 1X70MH/UNV J 10 1.00 80 0.68/0.29 Leads 4,6,8,9,10,11,
17,25,27,37,38,39
100W E17 1 Universal 51944 QTP 1X100MH/UNV F 10 1.00 112 0.95/0.40 Leads 4,6,8,9,10,11,
120-277 17,25,27,37,38,39
51945 QTP 1X100MH/UNV J 10 1.00 112 0.95/0.40 Leads 4,6,8,9,10,11,
17,25,27,37,38,39
T2 FLUORESCENT MINIATURE
Operates FM6/H, FM8/H, FM11/H, FM13/H
Primary37 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Wiring Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Method Footnotes
|
FM13/H 2 Universal 49734 QT-FM 50 1.00 33 0.28/0.14 Wiretrap 1,4,6,8,9,10,
120-277 Connectors 11,13,24,32
E
L
E
C
T
R
O
N
I
C
B
A
L
L
A
S
T
S
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 173-174
155
M
A
G
N
E
T
I
C
F
L
U
O
R
E
S
C
E
N
T
B
A
L
L
A
S
T
S
HOW TO READ PRODUCT INFORMATION - MAGNETIC FLUORESCENT BALLASTS
Primary No Input Input Input
|
Lamp of Voltage Product Pkg Ballast Power Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F34T12 2 120 48001 MB2x40/120RS-SRNK 10 0.88 73 0.65 1,2,3
F96T12/VHO 2 120 48131 MB2x96/VHO/120RS-SRNK 40.95 450 3.8 1,2,3
F15T12 1 120 48200 MB1x15/120PH/TP 16 0.79 32 0.60 1,2,3
HOW TO READ ORDERING ABBREVIATIONS
MB2x40/120RS-SRNK MB2x96/VHO/120RS-SRNK MB1x15/120PH-TP
MB Magnetic ballast MB Magnetic ballast MB Magnetic ballast
2x Number of lamps the ballast operates 2x Number of lamps the ballast operates 1x Number of lamps the ballast operates
40 Lamp wattage or length 96 Lamp wattage or length 15 Lamp wattage or length
120 Input voltage VHO Starting method/lamp type 120 Input voltage
RS Starting method/lamp type 120 Input voltage PH Starting method/lamp type
SRNK Product is Shrinkwrapped RS Starting method/lamp type TP Thermal protection
SRNK Product is Shrinkwrapped
BALLAST CATEGORIES
Number of lamps the 1x, 2x
ballast operates
Input voltage 120, 277
Starting method/lamp type IS - Instant start, RS - Rapid start, PH - Preheat/trigger start, CIRC - Circline, HO - High output, VHO - Very High Output
Sylvania Magnetic Fluorescent ballasts are all rated for 60Hz input frequency.
Rapid Start Ballasts
These ballasts operate the popular 40W T12 and T8 lamps with a smooth start to ensure proper operation. A rapid start ballast removes the need for the sepa-
rate starter required with pre-heat lamps and also eliminates the flicker associated with pre-heat starting.
Slimline Ballasts
Slimline ballasts are designed for use with single pin T12 lamps and do not require separate starters. Slimline ballasts start lamps with a high starting voltage
without preheating the coils. Slimline lamps are specially constructed to utilize this starting method, and provide good system efficacy because no power is
used to heat the coils.
HO and VHO Ballasts
HO and VHO ballasts are rapid start T12 ballasts designed to operate the High Output and Very High Output T12 lamps popular in retail and industrial environ-
ments. They come in larger versions of the standard magnetic F-Can to handle the higher power loads of these systems.
Trigger Start Ballasts
Trigger Start ballsts are designed to start a preheat lamp without the use of a starter.
HO Sign Ballasts
HO Sign ballasts are rapid start T12 ballasts designed for cold weather and outdoor applications which provide reliable performance in sign applications.
Circline and Pre-Heat Ballasts
These products are available for the most popular circline and pre-heat lamp types, and come in standard and thermally protected models. Pre-Heat ballasts
also require the use of an external starter to ignite the lamps.
For more information about Magnetic ballast warranties, please visit the warranty section of this catalog.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 173-174
156
M
A
G
N
E
T
I
C
F
L
U
O
R
E
S
C
E
N
T
B
A
L
L
A
S
T
S
CERTIFICATIONS -
Depicts ballast is listed by Underwriters Laboratories Inc. in accordance with UL 1029 for HID ballasts, and UL 935
for Fluorescent ballasts.
Depicts ballast is listed by Underwriters Laboratories Inc. in accordance with UL 1029 and CAN/CSA - 22.2 No. 74
for Canada.
Depicts ballast is a recognized component by Underwriters Laboratories Inc. in accordance with UL 1029 for US and
CAN/CSA - 22.2 No. 74 for Canada.
Depicts ballast is certified by the Canadian Standards Association in accordance with CAN/CSA - 22.2 No. 74-92.
Indicates SYLVANIA ballast complies with National Energy Conservation Amendments of 1988 (unless otherwise
indicated).
Indicates SYLVANIA ballast complies with Canadian Energy Standards (unless otherwise indicated).
M
A
G
N
E
T
I
C
F
L
U
O
R
E
S
C
E
N
T
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
157
RAPID START
T12 & T10
High Power Factor; Class A Sound Rating; MB2x30 also operates F30SS; MB1x40 also operates F40, FB40, FB40SS, F40T10, F30 or F30SS; MB2x40 also oper-
ates F40, FB40, FB40SS or F40T10; MB1x40/120RES is Normal Power Factor and operates only F40T12, FC12T9 or FC16T9
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F30T12 2 120 48409 MB2X30/120RS-SRNK 10 0.95 80 0.67 4,6,8,32,40,41,
43
277 48410 MB2X30/277RS-SRNK 10 0.95 80 0.29 4,6,8,32,40,41,
43
F34T12 1 120 48011 MB1X40/120RS-SRNK 10 0.91 44 0.38 4,6,8,32,
40,41,43
277 48120 MB1X40/277RS-SRNK 10 0.91 44 0.16 4,6,8,32,
40,41,43
2120 48001 MB2X40/120RS-SRNK 10 0.88 73 0.65 4,6,8,32,
40,41,43
277 48121 MB2X40/277RS-SRNK 10 0.89 77 0.29 4,6,8,32,
40,41,43
F40T12 1 120 48210 MB1X40/120RES-SRNK 16 0.60 31 0.53 4,6,8,32,40,43,
44,45
INSTANT START
T12 SLIMLINE
High Power Factor; Class B Sound Rating; MB2x48 also operates F48T12SS; MB1x96 & MB2x96 also operates F96T12SS, F84, F72, F64 or F60
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F48T12 2 120 48122 MB2X48/120IS-SRNK 60.93 87 0.77 4,6,8,12,41,43,
46
277 48123 MB2X48/277IS-SRNK 60.93 88 0.34 4,6,8,12,41,43,
46
F96T12 1 120 48124 MB1X96/120IS-SRNK 60.93 101 0.90 4,6,8,32,41,43,
46
277 48125 MB1x96/277IS-SRNK 60.93 101 0.39 4,6,8,32,41,43,
46
2120 48018 MB2X96/120IS-SRNK 60.93 160 1.39 4,6,8,32,
41,43,46
277 48126 MB2X96/277IS-SRNK 60.93 162 0.60 4,6,8,32,
41,43,46
RAPID START
T12HO
High Power Factor; Class C Sound Rating; MB1x96HO and MB2x96HO also operates F96T12HOSS, F84HO, F72HO, F60HO, F48HO, F42HO, F36HO or F24HO.
MB1/2x48/96HO also operates one F48HO, F60HO, F72HO , F84HO, F96HO or two F24HO or two F36HO
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F96T12/HO 1 120 48127 MB1X96/HO/120RS-SRNK 40.95 136 1.19 4,6,8,41,43,48,
49
277 48128 MB1X96/HO/277RS-SRNK 40.94 138 0.53 4,6,8,41,43,48,
49
2120 48025 MB2X96/HO/120RS-SRNK 40.95 243 2.05 4,6,8,41,
43,48,49
277 48027 MB2X96/HO/277RS-SRNK 40.95 242 0.90 4,6,8,41,
43,48,49
M
A
G
N
E
T
I
C
F
L
U
O
R
E
S
C
E
N
T
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
158
RAPID START
T12HO
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F48T12/HO 2 120 48151 MB1/2x48/96/HO/120RS-SRNK 40.95 154 1.33 4,6,8,43,48,49
T12HO SIGN BALLAST
Also operates any T12HO lamp within quantity of lamp and lamp length requirements, see www.sylvania.com for further information
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F96T12/HO 1-2 120 48225 MSB-12-0412-TP 10.88 124 1.10 5,6,8,48,49,52,
53
F72T12/HO 2-4 120 48226 MSB-24-0620-TP 10.92 266 2.23 5,6,8,48,49,52,
55
48227 MSB-24-1224-TP 10.83 290 2.51 5,6,8,48,49,52,
57
F120T12/HO 2-4 120 48228 MSB-24-2040-TP 10.80 471 3.96 5,6,8,48,49,52,
59
F72T12/HO 4-6 120 48229 MSB-46-1240-TP 10.78 383 3.37 5,6,8,48,49,52,
60
F96T12/HO 4-6 120 48232 MSB-46-2448-TP 10.85 588 4.92 5,6,8,48,49,52,
61
COMPONENTS
J-BOX COVER
Cover for Sign & F-Can Ballasts
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
48275 JBOXCOVER 2
(FOR SIGN AND FCAN BALLASTS)
RAPID START
T12VHO
High Power Factor; Class D Sound Rating; MB1x96VHO also operates F96T12VHOSS, F72T12VHO, F60T12VHO or F48T12VHO; MB2x96VHO also operates
F96T12VHOSS or F72T12VHO
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F96T12/VHO 1 120 48129 MB1X96/VHO/120RS-SRNK 40.92 218 1.96 4,6,8,41,43,48,
49
277 48130 MB1X96/VHO/277RS-SRNK 40.91 212 0.81 4,6,8,41,43,48,
49
2120 48131 MB2X96/VHO/120RS-SRNK 40.95 452 3.80 4,6,8,41,43,48,
49
277 48132 MB2X96/VHO/277RS-SRNK 40.93 423 1.57 4,6,8,41,43,48,
49
M
A
G
N
E
T
I
C
F
L
U
O
R
E
S
C
E
N
T
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
159
PREHEAT/TRIGGER START
T5, T8 & T12
Normal Power Factor; Class A Sound Rating; MB1x8 also operates F6T5 & F4T5; MB1x15, MB1x20 & MB2x20 operates F14T12, F15T12, F20T12, F14T8 &
F15T8
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F8T5 1 120 48475 MB1X8/120PH/TP/S 40 0.97 10 0.16 4,6,8,32,43
F15T12 1 120 48200 MB1X15/120PH/TP 16 0.98 33 0.69 4,6,8,32,40,43,
45
F20T12 1 120 48201 MB1X20/120PH/TP 40 0.83 22 0.34 4,6,8,32,62
48202 MB1X20/120PH 40 0.83 22 0.34 6,8,32,62
2120 48203 MB2X20/120PH/TP 16 0.58 41 0.47 4,6,8,32,40,43
RAPID START
T8
High Power Factor; Class A Sound Rating; MB1x17 also operates FBO16; MB1x25/32-LW also operates FO25; MB1x25/32 & MB2x25/32 also operates FBO32,
FBO31, FO25 & FBO24
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
F017 1 120 48312 MB1X17/120RS 10 1.05 31 0.27 4,6,8,32,40
F032 1 120 48096 MB1x25/32/120RS-LW 10 0.84 33 0.29 4,6,8,32,40
1120 48240 MB1X25/32/120RS-SRNK 10 0.94 44 0.39 4,6,8,32,40,43
FO32 1 277 48241 MB1X25/32/277RS-SRNK 10 0.93 43 0.16 4,6,8,32,40,43
2120 48242 MB2X25/32/120RS-SRNK 10 0.94 74 0.63 4,6,8,32,40,
43
277 48243 MB2X25/32/277RS-SRNK 10 0.93 75 0.28 4,6,8,32,40,
43
T9 CIRCLINE
Normal Power Factor; Class A Sound Rating; MB1x32 also operates FC16T9
Primary35 Input Input Input
|
Lamp No of Voltage Product Pkg Ballast Wattage Current Symbols &
|
Type Lamps (VAC) Number Ordering Abbreviation Qty Factor (W) (Amps) Footnotes
|
FC8T9 1 120 48230 MB1X22/120CIRC 16 0.82 29 0.63 4,6,8,32,40,43
FC12T9 1 120 48231 MB1X32/120CIRC 16 0.62 31 0.61 4,6,8,32,40,43
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
160
HOW TO READ PRODUCT INFORMATION - MAGNETIC HID BALLAST
Primary Input Input Max. Input Open
|
Lamp Voltage Product Pkg ANSI Power Current Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M250PS 120/208/ 47282 M250/SUPER5-PS-KIT 1M138 288 250/1.40 290 CWA 20,22,
240/277/ 1.30/1.10 24,25
480 0.65
H100 120/208/ 46522 H100-MULTI-KIT 1H38 120 1.05/0.60 250 CWA 20,22,
240/277 0.52/0.45 24,25
LU100 120 47304 LU100/120R 1S54 120 2.70 120 Reactor/NPF 21,22
Circuit Type CWA - Constant wattage autotransformer, CWI - Constant wattage isolated,
HX-HPF - (Autolag) High reactance autotransformer, R-NPF - Reactor normal power factor
HOW TO READ ORDERING ABBREVIATIONS
M250/SUPER5-PS-KIT H100-MULTI-KIT LU100/120R
MLamp Type-METALARC Metal Halide HLamp Type-Mercury LU Lamp Type-LUMALUX High Pressure Sodium
250 Lamp wattage 100 Lamp wattage 100 Lamp wattage
SUPER5 Input Voltage MULTI Input Voltage 120 Input Voltage
PS Pulse Start KIT Packaging configuration RBallast Type-Reactor Ballast
KIT Packaging configuration
BALLAST CATEGORIES
Lamp type M-METALARC metal halide, LU-LUMALUX High Pressure Sodium, H-Mercury
Input voltage Super5 - 120/208/240/277/480; Multi-120/208/240/277; 120/240; 120; 277; 480; 480/120T (480/120TAP)
SYLVANIA HID Ballasts are available in easy-to use replacement kits for the range of metal halide, high pressure sodium and mercury lamps. These ballast kits
help to eliminate the hassles of identifying what's required for a replacement or upgrade by providing an array of components in each kit. New Super5 Kits can
be used for multiple taps styles 120/208/240/277 & 480V application minimizing hassles associated with selecting the wrong voltage product. All are rated for
60Hz input frequency and utilize dry film capatitors where applicable.
METALARC®Metal Halide Magnetic Ballast Kits
Named for SYLVANIA METALARC lamps, these kits include core and coil, capacitors, ignitors (where required), brackets and mounting hardware.
Available for a broad range of metal halide and pulse start metal halide lamps, most kits are also suitable for use with like wattage mercury lamps. Each is clear-
ly labeled with the appropriate combinations.
METALARC Indoor Enclosed HID Ballasts
New Indoor Enclosed ballasts for indoor applications where remote mounting is required. Remote mounting allows for cooler ballast operation, easy replace-
ment and minimal noise.
F-Can HID Ballasts
New F-Can ballasts for indoor aplications operate a range of metal halide, pulse start metal halide and high pressure sodium lamps with minimal noise. Available
in a fluorescent can type ballast and are thermally protected.
LUMALUX®High Pressure Sodium Magnetic Ballast Kits
These kits, named for the SYLVANIA LUMALUX high pressure sodium lamps, include core and coil, capacitors, ignitors, brackets and mounting hardware.
LUMALUX High Pressure Sodium Reactor Ballasts
Available for low wattage lamps, these ballasts are the simple reactor ballasts popular for 120V applications. Power factor correction capacitors are available for
installations requiring higher power factors than normal.
MERCURY Magnetic Ballast Kits
These kits are available for the array of available mercury lamps and include core and coil, capacitor, brackets and mounting hardware. Some models also offer
dual lamp capability.
For more information about Magnetic ballast warranties, please visit the warranty section of this catalog.
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
161
METALARC®METAL HALIDE
CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M175 120/208/ 47243 M175/SUPER5-KIT 1M57, H39 210 1.96/1.15/ 305 CWA 8,14,20,48,65
240/277/480 1.00/0.86/0.54
120/208/ 47735 M175/MULTI-KIT 1M57, H39 210 1.80/1.04/ 305 CWA 8,4,20,48,65
240/277 0.90/0.78
480 47035 M175/480-KIT 1M57, H39 210 0.54 305 CWA 8,14,20,48,65
480/120TAP 47253 M175/480/120T-KIT 1M57, H39 210 0.54 305 CWA 8,14,20,48,65
120/277 47254 M175/120/277-KIT 1M57, H39 210 1.80/0.78 305 CWA 8,14,20,48,65
M250 120/208/ 47265 M250/SUPER5-KIT 1M58, H37 290 2.50/1.45/ 300 CWA 8,14,20,48,65
240/277/480 1.25/1.10/0.63
120/208/ 47737 M250/MULTI-KIT 1M58, H37 290 2.50/1.45/ 300 CWA 8,14,20,48,65
240/277 1.25/1.10
480 47611 M250/480-KIT 1M58, H37 290 0.63 300 CWA 8,14,20,48,65
480/120TAP 47268 M250/480/120T-KIT 1M58, H37 290 0.63 300 CWA 8,14,20,48,65
120/208/ 47049 M250/MULTI 3X4-KIT 1M58, H37 294 3.16/2.15/ 300 CWA 8,14,20,48,65
240/277 1.60/1.40
480 47050 M250/480-3X4-KIT 1M58, H37 294 0.86 300 CWA 8,14,20,48,65
M400 120/208/ 47338 M400/SUPER5-KIT 1M59, H33 458 4.00/2.30/ 300 CWA 8,14,20,48,65
240/277/480 2.00/1.70/1.00
120/208/ 47739 M400/MULTI-KIT 1M59, H33 458 4.00/2.30/ 300 CWA 8,14,20,48,65
240/277 2.00/1.70
480 47065 M400/480-KIT 1M59, H33 458 1.00 300 CWA 8,14,20,48,65
480/120TAP 47394 M400/480/120T-KIT 1M59, H33 458 1.00 300 CWA 8,14,20,48,65
120/240 47075 M2X400/120/240-KIT 1M59, H33 880 7.90/3.95 630 CWA 8,14,20,48,65
M1000 120/208/ 47427 M1000/SUPER5-KIT 1M47, H36 1080 9.20/5.30/ 420 CWA 8,14,20,48,65
240/277/480 4.60/4.00/2.30
120/208/ 47744 M1000/MULTI-KIT 1M47, H36 1080 9.00/5.20/ 421 CWA 8,14,20,48,65
240/277 4.50/3.90
480 47655 M1000/480-KIT 1M47, H36 1080 2.30 421 CWA 8,14,20,48,65
480/120TAP 47432 M1000/480/120T-KIT 1M47, H36 1080 2.30 421 CWA 8,14,20,48,65
M1500 120/208/ 46808 M1500/MULTI-KIT 1M48 1605 13.50/7.80/ 435 CWA 8,14,20,48,65
240/277 6.75/5.85
480 47095 M1500/480-KIT 1M48 1605 3.50 435 CWA 8,14,20,48,65
480/120TAP 47434 M1500/480/120T-KIT 1M48 1605 CWA 8,14,20,48,65
PULSE START CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M39 120/208/ 47001 M35/MULTI-HQ/CI-KIT 1M130 58 0.50/0.29/ 215 CWA 8,14,20,48,50,65
240/277 0.25/0.22
120/277 47203 M35/120/277-KIT 1M130 54 1.02/0.45 235 HX-HPF 8,14,20,48,50,65
M50 120/208/ 47007 M50/MULTI-KIT 1M110 67 1.33/0.77/ 250 HX-HPF 8,14,20,48,50,65
240/277 0.68/0.58
120/277 47204 M50/120/277-KIT 1M110 67 1.33/0.58 250 HX-HPF 8,14,20,48,50,65
M70 120/208/ 47013 M70/MULTI-KIT 1M98 95 1.70/0.96/ 250 HX-HPF 8,14,20,48,50,65
240/277 0.83/0.72
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
162
METALARC®METAL HALIDE
PULSE START CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M70 120/277 47217 M70/120/277-KIT 1M98 95 1.70/1.72 250 HX-HPF 8,14,20,48,50,65
120/208/ 47645 M70/MULTI-HQ/CI-KIT 1M98, M85, 95 0.94/0.55/ 215 CWA 8,14,20,48,50,65
240/277 M139, M143 0.48/0.41
M100 120/208/ 47019 M100/MULTI-KIT 1M90 130 2.16/1.25/ 250 HX-HPF 8,14,20,48,50,65
240/277 1.10/0.95
120/277 47219 M100/120/277-KIT 1M90 130 2.16/0.95 250 HX-HPF 8,14,20,48,50,65
M150 120/208/ 47682 M150/MULTI-PS-KIT 1M102 185 3.60/2.06/ 260 HX-HPF 8,14,20,48,50,65
240/277 1.78/1.55
47640 M150/MULTI-PS-CWA-KIT 1M81, M102, 189 1.80/1.03/ 215 CWA 8,14,20,48,50,65
240/277 M142 0.90/0.78
120/277 47228 M150/120/277-PS-KIT 1M102 185 3.60/1.55 260 HX-HPF 8,14,20,48,50,65
120/208/ 47229 M150/MULTI-KIT 1M81 185 3.60/2.05/ 245 HX-HPF 8,14,20,48,50,65
240/277 1.80/1.55
M175/PS 120/208/ 47686 M175/MULTI-PS-KIT 1M137, M152 208 1.80/1.10/ 275 CWA 8,14,20,48,50,65
240/277 0.90/0.80
480 46801 M175/480-PS-KIT 1M137, M152 208 0.50 275 CWA 8,14,20,48,50,65
M200/PS 120/208/ 47690 M200/MULTI-PS-KIT 1M136 232 2.00/1.20/ 270 CWA 8,14,20,48,50,65
240/277 1.00/0.90
480 46802 M200/480-PS-KIT 1M136 232 0.50 270 CWA 8,14,20,48,50,65
480/120TAP 47259 M200/480/120T-PS-KIT 1M136 232 0.50 270 CWA 8,14,20,48,50,65
HQI250 120/277 47273 M250/120/277-KIT 1M80 290 5.50/2.30 240 HX-HPF 8,14,20,48,50,65
M250/PS 120/208/ 47282 M250/SUPER5-PS-KIT 1M138, M153 288 2.50/1.40/ 290 CWA 8,14,20,48,50,65
240/277/480 1.30/1.10/0.65
120/208/ 47112 M250/MULTI-PS-KIT 1M138, M153 288 2.50/1.40/ 280 CWA 8,14,20,48,50,65
240/277 1.30/1.10
480 47106 M250/480-PS-KIT 1M138, M153 288 0.65 290 CWA 8,14,20,48,50,65
480/120TAP 47283 M250/480/120T-PS-KIT 1M138, M153 288 0.65 290 CWA 8,14,20,48,50,65
M320/PS 120/208/ 47676 M320/MULTI-PS-KIT 1M132 368 3.2/1.9/ 270 CWA 8,14,20,48,50,65
240/277 1.62/1.4
480 46803 M320/480-PS-KIT 1M132, M154 368 0.90 270 CWA 8,14,20,48,50,65
480/120TAP 47303 M320/480/120T-PS-KIT 1M132, M154 368 1.90 270 CWA 8,14,20,48,50,65
M350/PS 120/208/ 47695 M350/MULTI-PS-KIT 1M131 400 3.40/2.00/ 275 CWA 8,14,20,48,50,65
240/277 1.70/1.50
480 47697 M350/480-PS-KIT 1M131 400 0.90 275 CWA 8,14,20,48,50,65
480/120TAP 47337 M350/480/120T-PS-KIT 1M131 400 0.90 275 CWA 8,14,20,48,50,65
M400/PS 120/208/ 47400 M400/SUPER5-PS-KIT 1M135, M155 452 3.80/2.20/ 275 CWA 8,14,20,48,50,65
240/277/480 1.90/1.70/1.00
120/208/ 47132 M400/MULTI-PS-KIT 1M135, M155 452 3.80/2.20/ 270 CWA 8,14,20,48,50,65
240/277 1.90/1.70
480 47138 M400/480-PS-KIT 1M135, M155 452 1.00 270 CWA 8,14,20,48,50,65
480/120TAP 47403 M400/480/120T-PS-KIT 1M135, M155 452 1.00 275 CWA 8,14,20,48,50,65
M450/PS 120/208/ 47405 M450/MULTI-PS-KIT 1M144 508 4.30/2.50/ 275 CWA 8,14,20,48,50,65
240/277 2.20/1.90
480 46804 M450/480-PS-KIT 1M144 512 1.10 275 CWA 8,14,20,48,50,65
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
163
METALARC®METAL HALIDE
PULSE START CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M450/PS 480/120TAP 47408 M450/480/120T-PS-KIT 1M144 505 1.10 275 CWA 8,14,20,48,50,65
M750/PS 120/208/ 47717 M750/MULTI-PS-KIT 1M149 818 7.00/4.00/ 360 CWA 8,14,20,48,50,65
240/277 3.50/3.00
120/277/ 47409 M750/120/277/347/480-PS-KIT 1M149 818 7.00/3.00/ 360 CWA 8,14,20,48,50,65
347/480 2.45/1.75
480 47718 M750/480-PS-KIT 1M149 818 1.75 360 CWA 8,14,20,48,50,65
M1000/PS 120/208/ 47416 M1000/MULTI-PS-KIT 1M141 1080 9.00/5.20/ 421 CWA 8,14,20,48,50,65
240/277 4.50/3.90
120/277/ 47417 M1000/120/277/347/480-PS-KIT 1M141 1080 9.00/3.90/ 421 CWA 8,14,20,48,50,65
347/480 3.20/2.40
480 46805 M1000/480-PS-KIT 1M141 1080 2.30 421 CWA 8,14,20,48,50,65
HQI2000 277/347/ 47090 M2000/277/347/480-HQI-RL-KIT 12200 8.50/6.60/ 370 Reg. Lag 8,14,20,48,50,65
480 4.90
F-CAN
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M175 120/277 47743 M175/120/277/F-CAN 1M57, H39 205 1.75/0.75 310 CWA 6,8,33,48,68,69
M250 120/277 47751 M250/120/277/F-CAN 1M58, H37 295 2.60/1.10 310 CWA 6,8,33,48,68,69
M400 120/277 47759 M400/120/277/F-CAN 1M59, H33 460 3.90/1.70 300 CWA 6,8,47,48,68,69
PULSE START F-CAN
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M39 120/277 47680 M35/120/277/F-CAN 1M130 54 1.05/0.45 235 HX-HPF 6,8,11,48,50,68,69
M50 120/277 47195 M50/120/277/F-CAN 1M110 67 1.33/0.58 250 HX-HPF 6,8,33,48,50,68,69
M70 120/277 47693 M70/120/277/F-CAN 1M139 95 HX-HPF 6,8,48,50,68,69
47694 M70/120/277/F-CAN 1M98, M143, 94 1.95/0.85 250 HX-HPF 6,8,33,48,50,68,69
M139
M100 120/277 47734 M100/120/277/F-CAN 1M90 125 2.50/1.07 260 HX-HPF 6,8,33,48,50,68,69
M150 120/277 47738 M150-PS/120/277/F-CAN 1M102 180 CWA 6,8,48,50,68,69
M175/PS 120/277 47741 M175-PS/120/277/F-CAN 1M137 205 CWA 6,8,48,50,68,69
M200/PS 120/277 47747 M200-PS/120/277/F-CAN 1M136 232 CWA 6,8,48,50,68,69
M250/PS 120/277 47749 M250-PS/120/277/F-CAN 1M138, M153 295 2.70/1.17 300 CWA 6,8,33,48,50,68,69
M320/PS 120/277 47753 M320-PS/120/277/F-CAN 1M132, M154 375 3.35/1.46 300 CWA 6,8,47,48,50,68,69
M400/PS 120/277 47757 M400-PS/120/277/F-CAN 1M135, M155 465 4.10/1.80 285 CWA 6,8,47,48,50,68,69
INDOOR ENCLOSED
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M175 120/208/ 47153 M175/MULTI-I/D 1M57, H39 210 1.80/1.04/ 305 CWA 6,8,48,71
240/277 0.90/0.78
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
164
METALARC®METAL HALIDE
INDOOR ENCLOSED
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
M250 120/208/ 47158 M250/MULTI-I/D 1M58, H37 290 2.50/1.45/ 300 CWA 6,8,48,71
240/277 1.25/1.10
M400 120/208/ 47172 M400/MULTI-I/D 1M59, H33 458 4.00/2.30/ 300 CWA 6,8,48,71
240/277 2.00/1.70
M1000 120/208/ 47207 M1000/MULTI-I/D 1M47, H36 1080 9.00/5.20/ 421 CWA 6,8,48,71
240/277 4.50/3.90
LUMALUX®HIGH PRESSURE SODIUM
CORE & COIL REACTOR
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
LU35 120 47269 LU35/120R 12 S76 45 1.10 120 R-NPF 8,50,65,72
47537 LU35/120R-INT 12 S76 45 1.10 120 R-NPF 8,50,65,72,73
LU50 120 47274 LU50/120R 12 S68 60 1.45 120 R-NPF 8,50,65,72
47548 LU50/120R-INT 12 S68 60 1.45 120 R-NPF 8,50,65,72,73
LU70 120 47284 LU70/120R 12 S62 81 1.95 120 R-NPF 8,50,65,72
47558 LU70/120R-INT 12 S62 81 1.95 120 R-NPF 8,50,65,72,73
LU100 120 47304 LU100/120R 12 S54 120 2.70 120 R-NPF 8,50,65,72
47585 LU100/120R-INT 12 S54 120 2.70 120 R-NPF 8,50,65,72,73
LU150 120 47319 LU150/120R 12 S55 170 4.10 120 R-NPF 8,50,65,72
47616 LU150/120R-INT 12 S55 170 4.10 120 R-NPF 8,50,65,72,73
CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
LU35 120/240 47271 LU35/120/240-KIT 1S76 55 HX-HPF 8,14,20,50,65,72
LU50 120/277 47549 LU50/120/277-KIT 1S68 66 1.05/0.45 120 HX-HPF 8,14,20,50,65,72
LU70 120/208/ 47301 LU70/MULTI-KIT 1S62 91 1.43/0.85/ 120 HX-HPF 8,14,20,50,65,72
240/277 0.72/0.62
480 47579 LU70/480-KIT 1S62 91 0.35 120 HX-HPF 8,14,20,50,65,72
120/277 47571 LU70/120/277-KIT 1S62 91 1.43/0.62 120 HX-HPF 8,14,20,50,65,72
LU100 120/208/ 47316 LU100/MULTI-KIT 1S54 128 2.00/1.16/ 120 HX-HPF 8,14,20,50,65,72
240/277 1.00/0.87
480 47593 LU100/480-KIT 1S54 128 0.50 120 HX-HPF 8,14,20,50,65,72
120/277 47592 LU100/120/277-KIT 1S54 128 2.00/0.87 120 HX-HPF 8,14,20,50,65,72
LU150 120/208/ 47335 LU150/MULTI-KIT 1S55 188 2.81/1.65/ 120 HX-HPF 8,14,20,50,65,72
240/277 1.45/1.25
480 47619 LU150/480-KIT 1S55 188 0.80 120 HX-HPF 8,14,20,50,65,72
480/120TAP 47621 LU150/480/120T-KIT 1S55 190 HX-HPF 8,14,20,50,65,72
120/277 47617 LU150/120/277-KIT 1S55 188 2.81/1.25 120 HX-HPF 8,14,20,50,65,72
480 47623 LU150/480-CWA-KIT 1S55 185 0.40 110 CWA 8,14,20,50,65,72
LU200 120/208/ 47628 LU200/MULTI-KIT 1S66 230 1.96/1.13/ 182 CWA 8,14,20,50,65,72
240/277 0.98/0.85
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
165
LUMALUX®HIGH PRESSURE SODIUM
CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
LU200 480 47631 LU200/480-KIT 1S66 230 0.50 182 CWA 8,14,20,50,65,72
LU250 120/208/ 47634 LU250/SUPER5-KIT 1S50 295 2.50/1.50/ 190 CWA 8,14,20,50,65,72
240/277/480 1.30/1.10/0.65
120/208/ 47357 LU250/MULTI-KIT 1S50 295 2.50/1.50/ 185 CWA 8,14,20,50,65,72
240/277 1.30/1.10
480 47358 LU250/480-KIT 1S50 295 0.65 185 CWA 8,14,20,50,65,72
480/120TAP 47637 LU250/480/120T-KIT 1S50 295 CWA 8,14,20,50,65,72
120/277 47642 LU250/120/277-KIT 1S50 295 2.50/1.10 185 CWA 8,14,20,50,65,72
LU310 120/208/ 47643 LU310/MULTI-KIT 1S67 355 3.00/1.73/ 185 CWA 8,14,20,50,65,72
240/277 1.50/1.30
480 47644 LU310/480-KIT 1S67 355 0.75 185 CWA 8,14,20,50,65,72
LU400 120/208/ 47647 LU400/SUPER5-KIT 1S51 464 3.80/2.20/ 190 CWA 8,14,20,50,65,72
240/277/480 1.90/1.70/1.00
120/208/ 47364 LU400/MULTI-KIT 1S51 464 3.90/2.25/ 190 CWA 8,14,20,50,65,72
240/277 1.95/1.70
480 47376 LU400/480-KIT 1S51 464 1.00 190 CWA 8,14,20,50,65,72
480/120TAP 47657 LU400/480/120T-KIT 1S51 465 CWA 8,14,20,50,65,72
120/277 47656 LU400/120/277-KIT 1S51 464 3.90/1.70 190 CWA 8,14,20,50,65,72
LU750 120/208/ 47712 LU750/MULTI-KIT 1S111 830 6.80/4.00/ 220 CWA 8,14,20,50,65,72
240/277 3.50/3.10
480 47658 LU750/480-KIT 1S111 830 1.75 220 CWA 8,14,20,50,65,72
LU1000 120/208/ 47659 LU1000/SUPER5-KIT 1S52 1100 9.50/5.50/ 440 CWA 8,14,20,50,65,72
240/277/480 4.70/4.10/2.40
120/208/ 47389 LU1000/MULTI-KIT 1S52 1100 9.50/5.50/ 435 CWA 8,14,20,50,65,72
240/277 4.80/4.10
480 47391 LU1000/480-KIT 1S52 1100 2.40 435 CWA 8,14,20,50,65,72
F-CAN
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
LU35 120/277 47761 LU35/120/277/F-CAN 1S76 47 0.80/0.35 120 HX-HPF 6,8,33,50,68,69,72
LU50 120/277 47762 LU50/120/277/F-CAN 1S68 65 1.05/0.46 125 HX-HPF 6,8,33,50,68,69,72
LU70 120/277 47763 LU70/120/277/F-CAN 1S62 90 1.50/0.65 120 HX-HPF 6,8,33,50,68,69,72
LU100 120/277 47764 LU100/120/277/F-CAN 1S54 125 1.95/0.85 120 HX-HPF 6,8,33,50,68,69,72
LU150 120/277 47765 LU150/120/277/F-CAN 1S55 185 3.05/1.32 120 HX-HPF 6,8,33,50,68,69,72
LU250 120/277 47777 LU250/120/277/F-CAN 1S50 298 CWA 6,8,50,68,69,72
MERCURY VAPOR
CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
H46 120/208/ 46518 H50/MULTI-KIT 1H46 68 0.60/0.35/ 235 CWA 8,14,20,48,65
240/277 0.30/0.26
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
166
MERCURY VAPOR
CORE & COIL KITS
Primary36 Input Input Input Open
|
Lamp Voltage Product Pkg ANSI WattageCurrent Circuit Circuit Symbols &
|
Type (VAC) Number Ordering Abbreviation Qty Code (W) (Amps) Voltage Type Footnotes
|
H43 120/208/ 46519 H75/MULTI-KIT 1H43 92 0.80/0.46/ 250 CWA 8,14,20,48,65
240/277 0.40/0.35
H38/H44 120/208/ 46522 H100/MULTI-KIT 1H38, H44 120 1.05/0.60/ 250 CWA 8,14,20,48,65
240/277 0.52/0.45
277 47472 H100/277-KIT 1H38, H44 120 0.45 250 CWA 8,14,20,48,65
120/240 47471 H100/DUAL-KIT 1H38, H44 120 1.05/0.52 250 CWA 8,14,20,48,65
H39 120/208/ 47489 H175/MULTI-KIT 1H39 205 1.85/1.10/ 250 CWA 8,14,20,48,65
240/277 0.92/0.80
480 47490 H175/480-KIT 1H39 205 0.45 250 CWA 8,14,20,48,65
H37 120/208/ 47499 H250/MULTI-KIT 1H37 285 2.55/1.5/ 260 CWA 8,14,20,48,65
240/277 1.27/1.1
480 47500 H250/480-KIT 1H37 285 0.62 270 CWA 8,14,20,48,65
480/120TAP 46531 H250/480/120T-KIT 1H37 285 0.62 270 CWA 8,14,20,48,65
H33 120/208/ 47509 H400/MULTI-KIT 1H33 455 CWA 8,14,20,48,65
240/277
480 47510 H400/480-KIT 1H33 454 1.00 250 CWA 8,14,20,48,65
480/120TAP 46533 H400/480/120T-KIT 1H33 454 1.00 250 CWA 8,14,20,48,65
120 47517 H2X400/120-KIT 1H33 880 7.8 495 CWA 8,14,20,48,65
277 47518 H2X400/277-KIT 1H33 880 3.38 495 CWA 8,14,20,48,65
H36 120/208/ 47524 H1000/MULTI-KIT 1H36 1080 9.2/5.36/ 420 CWA 8,14,20,48,65
240/277 4.6/4.0
480 47525 H1000/480-KIT 1H36 1080 2.3 420 CWA 8,14,20,48,65
COMPONENTS
CAPACITORS
Replacement capacitors for SYLVANIA HID ballasts only
48
|
Product Symbols &
|
Number Ordering Abbreviation General Description Diameter Height Footnotes
|
47912 CAP 24MF 480VAC 24MF 480VAC (MIN) Capacitor
47920 CAP 26MF 525VAC 26MF 525VAC Capacitor
47926 CAP40MFD280VAC 40MF 280 VAC Capacitor
47927 CAP52MFD280VAC 52MF 280 VAC Capacitor
47932 CAP 35MF 280VAC 35MF 280 Capacitor
47938 CAP28.5MFD330VAC 28.5MF 330 VAC (MIN) Capacitor
47942 CAP 55MF 300VAC 55MF 300VAC Capacitor
47952 CAP 10MF 400VAC 10MF 400VAC Capacitor
47954 CAP 15MF 400VAC (MIN) 15MF 400VAC Capacitor
M
A
G
N
E
T
I
C
H
I
D
B
A
L
L
A
S
T
S
• Data shown is based on primary lamp type.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 168-170
167
COMPONENTS
IGNITORS
Replacement ignitors for SYLVANIA HID ballasts only
48
|
Product Symbols &
|
Number Ordering Abbreviation General Description Diameter Height Footnotes
|
47996 IGNITOR MH PS 35-150 35-150W MH Ignitor 1.25x2.00 2.50
47997 IGNITOR MH PS 175-400 175-400W MH Ignitor 1.75 2.00
47998 IGNITOR MH PS 750-1000 750-1000W MH Ignitor 1.17x1.90 2.50
47843 IGNITOR HPS 35-150 35-150W HPS Ignitor 1.375 2.40
47844 IGNITOR HPS 200-400 200-400W HPS Ignitor 1.25x2.00 2.50
47847 IGNITOR HPS 600-1000 600-1000W HPS Ignitor 1.87x1.89 2.50
47877 HPS IGN 35-150W 35-150W HPS Ignitor 2.315 2.83
B
A
L
L
A
S
T
S
For more complete product information visit www.sylvania.com
168
SYMBOLS & FOOTNOTES FOR ELECTRONIC & MAGNETIC BALLAST CONTROL SYSTEMS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Product is Canadian Standards Association certified for U.S. and Canadian markets
Electronic Control Systems Logo
Dimmable Logo T5
QUICK60+®warranty
QUICKSENSE®Circuitry
PROStart®Programmed Start
cULus
This lamp or ballast meets minimum Federal efficiency standards.
Product is Canadian Standards Association approved for the Canadian market
Product is Canadian Standards Association certified for the U.S. market
Product complies with the requirements of Canadian Standards Association energy efficiency and performance standards
Product is Underwriters Laboratories listed
Product is an Underwriters' Laboratories recognized component, certified for both U.S. and Canadian requirements
Product is an Underwriters' Laboratories recognized component
Footnote Description
1Remote Mounting up to 18 feet
270C Max Case Temperature
4UL Listed Class P, Type 1 Outdoor
5Insulate unused leads
6Ground ballast case
7Lampholder must be shorted per diagram
8Install in accordance with National Electric Codes
9Complies with FCC 47 CFR Part 18, Non-Consumer
10 ANSI 62.41 Cat. A Transient Protection
11 Class A Sound Rating.
12 Minimum Starting Temperature: 0F/-18C.
13 Input Frequency: 60Hz.
14 Product is a kit containing the core & coil, capacitor, ignitor (where required), brackets and mounting hardware
15 Remote Mounting up to 12 feet
16 Remote Mounting up to 10 feet
17 Input Frequency: 50/60Hz.
18 Wiring diagram applies to instant start standard, low power (LP), PLUS, and HD10 ballast types.
19 Oil Filled Capacitor
20 Product contains installation instructions
B
A
L
L
A
S
T
S
For more complete product information visit www.sylvania.com 169
SYMBOLS & FOOTNOTES FOR ELECTRONIC & MAGNETIC BALLAST CONTROL SYSTEMS
Footnote Description
21 Remote mounting defined by harness length
22 Remote Mounting up to 19 feet (keep red wires short for 1&2 lamp).
23 Type CC
24 75C Max Case Temperature
25 Minimum Starting Temperature: -5F/-20C.
26 Remote Mounting up to 19 feet (keep red wires short for 1&2 lamp models).
27 ANSI C62.41 cat. B3 Transient Protection.
28 Remote mounting - Typically 6ft with suitable ground plane, but varies by model and application. Contact ECS Application Engineering for
information on longer applications.
29 Remote Mounting up to 7 feet
30 Minimum Starting Temperature: 60F/16C.
31 Data shown is at full light output.
32 Minimum Starting Temperature: 50F/10C.
33 Class B Sound Rating.
34 Remote mounting up to 8 feet.
35 85C Max Case Temperature
36 90C Max Case Temperature
37 Suitable for recessed use.
38 90C max. case Temperature, thermally protected.
39 Remote mounting - Typically 6ft, but varies by application, remote capability up to 15ft. Contact OSRAM SYLVANIA for details.
40 Mount lamps within 1/2 " of grounded metal reflector
41 Minimum starting temperature: 60 F / 16 C with SS lamps
42 Full light output
43 Product is individually shrink-wrapped
44 For residential use only
45 Circuit Interrupting Lampholder required
46 Cutout Lampholder
47 Class C Sound Rating.
48 Minimum starting temperature: -20 F / -29 C
49 Mount lamps within 1" of grounded metal reflector
50 High Voltage Pulse Present on Open Circuit
51 White painted metal enclosure
52 Thermal protection: Class P, Type 2 outdoor
53 For any 1 or 2 T12/RS/HO 800mA lamp combination provided total lamp length is not less than 4 ft. nor more than 12 ft.
54 Class D Sound Rating.
55 For any 2, 3 or 4 T12/RS/HO 800mA lamp combination provided total lamp length is not less than 6 ft. nor more than 20 ft.
56 Normal ambient temperature: 77 F / 25 C
57 For any 2, 3 or 4 T12/RS/HO 800mA lamp combination provided total lamp length is not less than 12 ft. nor more than 24 ft.
58 Class E sound rating
59 For any 2, 3 or 4 T12/RS/HO 800mA lamp combination provided total lamp length of each circuit (A) and circuit (B) is not less than 10 ft. nor
more than 20 ft. Circuit "A" consists of lamp 1, 2 Circuit "B" consists of lamp 3, 4
60 For any 4,5 or 6 T12/RS/HO 800mA lamp combination provided total lamp length of each circuit (A) and circuit (B) is not less than 6 ft. nor
more than 20 ft. Circuit "A" consists of lamp 1, 2, 3 Circuit "B" consists of lamp 4, 5, 6
61 For any 4, 5 or 6 T12/RS/HO 800 mA lamp combination provided total lamp length of each circuit (A) and circuit (B) is not less than 12 ft.
nor more than 24 ft. Circuit "A" consists of lamp 1, 2, 3 Circuit "B" consists of lamp 4, 5, 6
62 Starter required
63 High power factor
B
A
L
L
A
S
T
S
For more complete product information visit www.sylvania.com
170
SYMBOLS & FOOTNOTES FOR ELECTRONIC & MAGNETIC BALLAST CONTROL SYSTEMS
Footnote Description
64 Connector Included
65 Ground Ballast Core
66 Maximum ambient temperature: 104 F / 40 C
67 Dry Capacitor
68 Suitable for Recessed Use Do not install insulation within 3 inches of ballast sides or above ballast in such a manner to entrap heat.
69 UL Listed Type 1 Outdoor, Auto-reset thermal protector
70 Minimum starting temperature: -22 F / -30 C
71 Insulate unused leads individually for 600V
72 Minimum Starting Temperature: -40F/-40C.
73 Reactor with Integral Ignitor
74 Contact OSRAM SYLVANIA for UL benchtop coil rise code
75 Remote mounting up to 18 feet. Keep blue wires short i.e. lamp(s) attached to the blue leads to remain in the fixture that houses the ballast.
76 65C Max Case Temperature.
77 Use only with an overall electrical enclosure - protect from exposure to water.
78 Minimum starting temperature for 70W lamp: -13F/-25C.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
171
OSRAM BRAND
PHOTO-OPTIC LIGHT SOURCES
Lighting to provide solutions in diverse applications such as effect lighting, stage, studio, TV, projection systems,
microlithography, medical/scientific, industrial, and airfield/aircraft.
Photo-Optic Lamp Types
HALOGEN
Airfield/Aircraft
Audio Visual
Special Purpose Heat Lamps
Studio, Theatre, TV & Video
HPL
HPR
OSRAM STUDIOLINE®
DISCHARGE
HBO®
HMD®
HMI®
HMP®
HSD®
HSR®
HTI®
LINEX®
VIP®
XBO®
XERADEX®
The following item was accepted into the 2003 IESNA Progress Report which recognizes innovative products
introduced to the industry during that year.
LINEX Mercury-Free Xenon Fluorescent Systems
P
H
O
T
O
O
P
T
I
C
S
P
E
C
I
A
L
T
Y
IMPORTANT!
PHOTO-OPTIC WARNINGS
In accordance with ANSI/IESNA Standard RP-27, all Photo-Optic Discharge lamps are Risk Group 3 products, and all Photo-Optic Incandescent
and Tungsten Halogen lamps are Risk Group 2 products.
Please read and understand the Safety and Warning Instructions for each lamp type before use. Safety and Warning Instructions can be found at the
end of this Photo-Optic section.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
172
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
AUDIOVISUAL
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
BAA 54924 BAA Projector 75 28 GX5.3 2000 MR16 24
BBA 11619 BBA 118V Photoflood 250 118 Med 4 A21 12
No.1/Enlarger & Printer
BCK 54576 BCK Projector - Slide 500 120 G17t 50 T6 24 1
BHC/DYS/DYV 54836 BHC/DYS/DYV Projector, Microfilm, 600 120 GZ9.5 17500 75 T6 24
Stage & Studio
BHC/DYS/DYV/X 54868 BHC/DYS/DYV/X Projector, Microfilm, 600 120 GZ9.5 14500 250 T6 24
Stage & Studio
BHC/DYS/DYV-5 54835 BHC/DYS/DYV-5 Projector, Microfilm, 600 125 GZ9.5 17500 75 T6 24 2
Stage & Studio
BRJ/EVB 54039 BRJ/EVB 64633 HLX Projector, Microfilm, 150 15 G6.35 5600 50 T3.25 100
Microscope, Studio
BRL 54034 BRL 64610 HLX Projector, Microfilm, 50 12 G6.35 1600 50 T3 100
Microscope, Studio
BRL 54035 BRL 64610 HLX BULK Project, Microfilm, 50 12 G6.35 1600 50 T3 250
Microscope, Studio
BRN 54698 BRN Projector 1200 120 G17q 20 T7 24 3
BVA 54673 BVA Projector 900 120 GY9.5 75 T7 24
BVE 54812 BVE Projector, Microfilm, 625 120 GY9.5 50 T6 24
Stage & Studio
CAX 58831 CAX Projector, Microfilm, 50 120 DC Bayonet 750 250 T4 24
Microscope, Studio
CBA 54580 CBA Projector - Slide 500 120 G17t 50 T6 24 1
DDK 54729 DDK Projector 80 19 GX5.3 150 50 T3.15 24 4
DDL 54660 DDL Projector - Microfilm 150 20 GX5.3 500 MR16 24
DDM 54737 DDM Projector - Slide 80 19 GX5.3 400 50 MR16 24 4
DDS 54944 DDS Projector - Microfilm 80 21 GX5.3 1000 MR16 24
DED 54726 DED Projector - Microfilm 85 14 GX5.3 150 1000 MR16 24 4
DEK/DFW 74440 DEK/DFW Projector 500 120 Trufocus T12 24
DNE 54409 DNE Projector 150 120 GX7.9 100 15 TB16 24 4
DNF 54411 DNF Projector - 8mm 150 21 GX7.9 300 25 MR18 24
DVY 54528 DVY Projector, Stage & 650 120 G5.3 20000 25 T6 12
Studio
DYH 54561 DYH Projector, Stage & 600 120 G5.3 17000 75 T5 24
Studio
DZE 54755 DZE Projector, Microfilm, 150 24 GZ9.5 4000 100 T4 24
Stage & Studio
EBV 11558 EBV 118V Super Photoflood/ No.2 500 118 Med Brass 17800 8 PS25 24
ECA 13365 ECA 120V Super Photoflood 250 120 Med Brass 6500 20 A23 24
ECT 11560 ECT 120V Photoflood 500 120 Med Brass 13650 60 PS25 24
EFM 54123 EFM 64607 Projector - 8mm 50 8 GZ6.35 50 MR16 20
EFN 54126 EFN 64615 HLX Projector - 8mm 75 12 GZ6.35 50 MR16 20
EFP 54189 EFP 64627 HLX Projector - 8mm 100 12 GZ6.35 50 MR16 20
EFP/X 54192 EFP/X 64629 HLX Projector - 8mm 100 12 GZ6.35 600 MR16 20
EFR 54210 EFR 64634 HLX Projector - 8mm 150 15 GZ6.35 50 MR16 20
EFR-5/X 54211 EFR-5/X 64620 HLX Projector - 8mm 150 15 GY6.35 500 MR16 20
EHA 54585 EHA Projector, Microfilm, 500 120 GY9.5 50 T6 24 3
Stage & Studio
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
173
AUDIOVISUAL
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
EHE 54038 EHE 64626 HLX Projector 100 12 PG22 3600 50 T4 30
EHJ 54045 EHJ 64655 HLX Projector, Microfilm, 250 24 G6.35 10000 50 T4 100
Microscope, Studio
EJA 54753 EJA Projector - Fiber 150 21 GX5.3 354 40 MR16 24
optics
EJL 54730 EJL Projector - 16mm 200 24 GX5.3 725 50 MR16 24 4
Color printer
EJM 54747 EJM Projector - 8mm 150 21 GX5.3 170 40 TB18 24 4
EJV 54732 EJV Projector - 8mm, 150 21 GX5.3 270 100 MR16 24 4
Printer
EKE 54842 EKE Projector - 8mm, 150 21 GX5.3 80 200 MR16 24 4
Fiber-Optics
EKE/X 58771 EKE/X Projector - 8mm, 150 21 GX5.3 80 1000 MR16 24 4
Fiber-Optics
EKP/ENA 54734 EKP/ENA Projector - 8mm 80 30 GX5.3 115 25 MR16 24 4
ELC 54212 ELC 64653 HLX Overhead projection, 250 24 GX5.3 50 MR16 20
fiber-optic, entertainment
ELC 54840 ELC Overhead projection, 250 24 GX5.3 800 50 MR16 24 4
fiber-optic, entertainment
ELC-3/X 54841 ELC-3/X Overhead projection, 250 24 GX5.3 550 300 MR16 24 4
fiber-optic, entertainment
ELC-7/X 54811 ELC-7/X BULK Overhead projection, 250 24 GX5.3 475 700 MR16 100 4
fiber-optic, entertainment
ELC-7/X 54814 ELC-7/X Overhead projection, 250 24 GX5.3 475 700 MR16 24 4
fiber-optic, entertainment
ELC-HL 54804 ELC-HL Overhead projection, 250 24 GX5.3 950 50 MR16 24
fiber-optic, entertainment
ELD 54745 ELD Projector - Microfilm 150 21 GX5.3 350 40 MR16 24 4
ELH 54776 ELH Projector - Overhead 300 120 GY5.3 525 35 MR16 24 4
ELS 54810 ELS Projector 50 16 GX7.9 20 650 TB14 24 4
ELV 54765 ELV Projector 150 22 GX7.9 225 100 TB18 24 4
ELZ 54816 ELZ Projector 150 21 GX7.9 350 60 TB18 24 4
EMG 54828 EMG Projector 500 220 GY9.5 75 T6 24
EMM/EKS 54960 EMM/EKS Projector - 16mm 250 24 GX7.9 725 50 MR14 24 4
ENG 54957 ENG Projector 300 120 GY5.3 690 15 MR16 24 4
ENH 54986 ENH Projector - Slide 250 120 GY5.3 340 175 MR16 24 4
ENH-5 54988 ENH-5 Projector - Overhead 250 125 GY5.3 340 175 MR16 24 4
ENL 58786 ENL Projector - Display, 50 12 GX5.3 85 4000 MR16 24
Fiber-Optics
ENX 54984 ENX Projector - Overhead 360 82 GY5.3 460 75 MR16 24 4
ENX-5 54913 ENX-5 Projector - Overhead 360 86 GY5.3 540 75 MR16 24 4
ENX-7 54916 ENX-7 Projector - Overhead 360 88 GY5.3 540 75 MR16 24 4
EPR 54829 EPR Projector 500 120 G17t 50 T6 24 1
EPS 54977 EPS Projector 500 240 G17t 50 T6 24 1,3
EPS/230 54975 EPS/230 Projector 500 230 G17t 50 T6 24 3,5
EPT 58782 EPT Projector - 42 11 GX5.3 8000 MR16 24
Fiber-Optics
EPV 54926 EPV Projector - Microfilm 90 14 GX5.3 36 500 MR16 24 4
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
174
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
AUDIOVISUAL
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
EPX 54927 EPX Projector - Microfilm 90 14 GX5.3 43 500 MR16 24 4
EPZ 54743 EPZ Projector - Microfilm 50 14 GX5.3 80 3000 MR16 24 4
ERK 55050 ERK BULK Projector 12 6 Wedge 150 T2.25 500
ERM 55054 ERM BULK Projector 7 6 Wedge 30 T2.25 500
ESA/FHD 54025 ESA/FHD 64225 Projector 10 6 G4 200 100 T3 100
ESB 54019 ESB 64250 HLX Projector 20 6 G4 480 100 T3.5 100
ETJ 54928 ETJ Projector 250 120 GY5.3 600 175 MR16 24 4
EVA 54052 EVA 64623 HLX Projector, Microfilm, 100 12 GY6.35 2800 2000 T4 100
Microscope, Studio
EVC 54047 EVC 64657 HLX Projector, Microfilm, 250 24 G6.35 9000 300 T4 100
Microscope, Studio
EVD 54100 EVD 64663 HLX Projector, Microfilm, 400 36 G6.35 16000 50 T6 24 6
Studio
EVD 54103 EVD 64663 HLX BULK Projector, Microfilm, 400 36 G6.35 16000 50 T6 100
Studio
EVW 54723 EVW Projector 250 82 GY5.3 390 50 MR16 24 4
EXR 54392 EXR Projector - Slide 300 82 GX5.3 925 35 MR13 24 4
EXR 54393 EXR BULK Projector - Slide 300 82 GX5.3 35 MR13 100 4
EXW 54388 EXW Projector - Slide 300 82 GX5.3 1050 15 MR13 24 4
EXY 54394 EXY Projector - Slide 250 82 GX5.3 400 200 MR13 24 4
EYB 54446 EYB Projector, Stage & 360 82 G5.3 10000 75 T3.5 24
Studio
EYB-5 54448 EYB-5 Projector, Microfilm, 360 86 G5.3 10000 75 T3.5 24
Stage & Studio
EYB-7 54455 EYB-7 Projector, Microfilm, 360 88 G5.3 10000 75 T3.5 24
Stage & Studio
EZE 54386 EZE Projector, Stage & 150 82 GX5.3 350 150 MR13 24 4
Studio
FBV 54568 FBV Projector, Microfilm, 250 30 E10 7000 6 T3 12
Stage & Studio
FCR 54036 FCR 64625 HLX Projector, Microfilm, 100 12 GY6.35 3600 50 T3.5 100
Microscope, Studio
FCS 54041 FCS 64640 HLX Projector 150 24 G6.35 6000 50 T4 100
FCS 54042 FCS 64640 HLX BULK Projector 150 24 G6.35 6000 50 T4 250
FDS/DZE 54055 FDS/DZE 64643 Projector, Microfilm, 150 24 GY9.5 5000 100 T4 30
Microscope, Studio
FDT 64628 54031 FDT 64628 Projector, Stage & 100 12 GY9.5 3000 50 T4 30
Studio
FDV 54054 FDV 64642 HLX Projector, Microfilm, 150 24 G6.35 5000 300 T4 100
Microscope, Studio
FHS 54979 FHS Projector - Slide 300 82 GX5.3 650 70 MR16 24 4
FKT/EYH 54547 FKT/EYH Projector - Video 250 120 G5.3 5400 200 T6 24
Camera
FLE 54383 FLE Projector 360 82 GY5.3 1250 75 MR16 24 4,7
FLT 54440 FLT Projector - Video 25 14 G4 500 MR11 24 8
Camera, Microfilm
FNS 58635 FNS 64512 Projector, Stage & 300 120 GX6.35 9500 15 T5 25
Studio
FNT 54044 FNT 64656PT HLX Projector, Microfilm, 275 24 G6.35 10000 75 T4 100
Microscope, Studio
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
175
AUDIOVISUAL
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
FNT 54046 FNT 64656PT HLX BULK Projector, Microfilm, 275 24 G6.35 10000 75 T4 250
Microscope, Studio
FSG 54899 FSG Projector 1200 120 P28s 28000 100 T7 12
FSX 54897 FSX/230 Projector 400 230 GY9.5 75 T6 24 3
FSY 54898 FSY Projector 400 240 GY9.5 75 T6 24 3
FXL 54912 FXL Projector - Overhead 410 82 GY5.3 640 75 MR16 24
FXL-HL 54904 FXL-HL Projector - Overhead 410 82 GY5.3 850 40 MR16 24 4
GCB 54430 GCB Projector, Stage & 200 30 G5.3 5300 200 T3 24
Studio, Video
GCC 54432 GCC Projector, Stage & 100 12 G5.3 3100 200 T3 24
Studio
GCD 54845 GCD Projector, Microfilm, 590 50 GZ9.5 21500 50 T6 24
Stage & Studio
53998 64638 HLX Projector 100 24 G6.35 2900 300 T3 100
53999 64265 HLX Projector 30 6 G4 765 100 T2 100
54021 64251 HLX Projector 20 6 PG22 500 100 T3 30
54022 64260 Projector 30 12 PG22 800 50 T3 30
54023 64261 Projector 30 12 G6.35 750 50 T3.25 100
54026 62138 HLX Projector 100 12 GZ6 25 T3 100
54027 64275 Projector 35 6 G4 780 50 T3 100
54028 64611 HLX Projector 50 12 G6.35 1350 100 T3.25 100
54032 64621 HLX Projector, Microfilm, 100 12 PG22 2750 2000 T3 30
Stage & Studio, Aircraft
54050 64223 Projector 10 6 G4 150 300 T3 100
54056 64650 Projector, Microfilm, 50 23 G6.35 1000 1300 T4 100
Microscope, Studio
54057 64664 HLX Projector, Microfilm, 400 36 G6.35 14500 150 T6 25 9
Microscope, Studio
54058 64665 HLX Projector, Microfilm, 400 36 G6.35 12200 300 T6 25
Microscope, Studio
54120 64258 HLX Projector 20 12 G4 2000 T3 100
54121 64617S Projector 75 12 G5.3-4.8 25 MR11 20
54122 64255 Projector 20 8 GZX4 50 MR11 20
54124 64617 Projector 75 12 G5.3-4.8 25 MR11 20
54125 64624 Projector 100 12 G5.3-4.8 25 MR11 20
54136 64654 HLX Projector, Microfilm, 250 24 GY9.5 9000 300 T6 30
Microscope, Studio
54138 64602 Projector, Microfilm, 50 12 G6.35 1000 1100 T3.25 100
Microscope, Studio
54214 64637 Projector 100 12 GZ6.35 1500 MR16 20
54233 64635 HLX Projector, Fiber-Optic 150 15 GZ6.35 50 MR16 20
54400 85T3/RM Projector 85 82 GX5.3 40 MR16 24
54466 120/T4/SPECIAL Projector 120 24 Special 2750 500 T4 24
58729 60T4QCL Medical Overhead 60 24 BA15d 1280 500 T4 12
Illumination
58939 220T4Q/2PPF Medical Overhead 220 22 GY9.5 6200 200 T4 12
Illumination
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
176
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
AUDIOVISUAL
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
58941 235T4Q/2PPF Medical Overhead 235 33 GZ9.5 5800 200 T4 12
Illumination
76302 70335 BULK Special Purpose 27 6 Special 200
76304 70314 (390153) Special Purpose 25 6 P47D 100
76305 70313 (390158) Special Purpose 30 6 P47D 100
76311 8013 Projector 10 6 BA15d 200 100 10
76313 8017 Projector 15 6 DC Bayonet 1000 100
76314 8018 Projector 15 6 DC Bayonet 100 100 10,11
76317 8025 Projector 6 BA20d 300 100 10
76319 8029 Projector 60 15 BA20d 25 100
76321 8100 Projector 5 E14 600 100
76362 91645 Special Purpose 50 110 PY280 100
STUDIO, THEATRE, TV & VIDEO
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
BCM 54694 BCM Stage & Studio 20000 230 G38 580000 350 T32 1
BTL 54685 BTL Stage & Studio 500 120 P28s 11000 750 T6 12
BTM 54686 BTM Stage & Studio 500 120 P28s 13000 100 T6 12
BTN 54687 BTN Stage & Studio 750 120 P28s 17000 500 T7 12
BTP 54688 BTP Stage & Studio 750 120 P28s 20000 200 T7 12
BTR 54689 BTR Stage & Studio 1000 120 P28s 27500 250 T6 12
BVM 58638 BVM 64540 Stage & Studio 650 230 GX6.35 20000 15 T8 25 12
BVT 54690 BVT Stage & Studio 1000 120 P40s 23000 500 T7 6
BVV 54691 BVV Stage & Studio 1000 120 P40s 27500 200 T6 6
BVW 54692 BVW Stage & Studio 2000 120 P40s 59000 280 T9.5 6
CXZ 54717 CXZ Stage & Studio 1500 120 G38 38500 325 T8 6
CYV 54706 CYV Stage & Studio 1000 120 G38 27500 200 T7 6
CYX 54613 CYX Stage & Studio 2000 120 G38 55000 300 T9 6
DNS/FMC 54655 DNS/FMC Stage & Studio 500 120 P28s 11000 500 T6 24
DNT/FMD 54658 DNT/FMD Stage & Studio 750 120 P28s 17000 500 T7 24 10
DPY 54647 DPY Stage & Studio 5000 120 G38 143000 500 T17 1
DTA 54716 DTA Stage & Studio 1500 120 P40s 39000 100 T8 6
DTY 54696 DTY Stage & Studio 10000 120 G38 290500 350 T24 1
DWE 54500 DWE Stage & Studio 650 120 Screw Term 24000 100 PAR36 12
DWT 58937 DWT Stage & Studio 1000 120 RX7s 22000 2000 T6 12
DXW 53997 DXW Stage & Studio 1000 120 R7s 28000 150 T5 12 13
EFX 54787 EFX Stage & Studio 500 120 G22 10000 2000 T5 12
EGE 54648 EGE Stage & Studio 500 120 P28s 10000 2000 T5 12
EGG 54652 EGG Stage & Studio 750 120 P28s 15000 2000 T5 12
EGJ 54654 EGJ Stage & Studio 1000 120 P28s 25500 400 T6 12
EGK 54656 EGK Stage & Studio 1000 120 P28s 24500 400 T6 12
EGN 54659 EGN Stage & Studio 500 120 G22 13000 100 T6 12
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
177
STUDIO, THEATRE, TV & VIDEO
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
EGR 54662 EGR Stage & Studio 750 120 G22 20000 200 T7 12
EGT 54664 EGT Stage & Studio 1000 120 G22 27500 250 T6 12
EGW 58637 EGW 64535 Stage & Studio 650 120 GX6.35 20000 15 T8 25
EHC/EHB 54506 EHC/EHB Stage & Studio 500 120 G9.5 13000 300 T4 12
EHD 54508 EHD Stage & Studio 500 120 G9.5 10600 2000 T4 12
EHF 54510 EHF Stage & Studio 750 120 G9.5 20400 300 T5 12
EHG 54512 EHG Stage & Studio 750 120 G9.5 15400 2000 T5 12
EHP 58942 EHP Stage & Studio 300 120 R7s 5000 2500 T4 12
EHR 58936 EHR Stage & Studio 400 120 R7s 7500 2000 T4 12
EHZ 54550 EHZ Stage & Studio 300 120 R7s 5900 2000 T2.5 12 14
EJG 54598 EJG Stage & Studio 750 120 R7s 20600 400 T3 12
EKB 54837 EKB Stage & Studio 420 120 GZ9.5 11000 75 T6 24
FAD 54574 FAD Stage & Studio 650 120 R7s 16500 100 T4 12
FAL 58860 FAL Projector, Stage & 420 120 R7s 11000 75 T4 24 14
Studio
FCB 54483 FCB Projector, Stage & 600 120 R7s 16500 75 T4 24
Studio
FCM 54442 FCM Stage & Studio 1000 120 R7s 28000 400 T3 12
FDA 54471 FDA Stage & Studio 400 120 R7s 10400 250 T4 12 14
FDB 54435 FDB Stage & Studio 1500 120 R7s 41200 400 T4 12
FDN 54534 FDN Stage & Studio 500 120 R7s 12800 400 T2.5 12
FEL 54570 FEL Stage & Studio 1000 120 G9.5 27500 300 T6 12
FEP/220 54636 FEP/220 Stage & Studio 1000 220 G9.5 23000 150 T6 12
FEP/240 54515 FEP/240 Stage & Studio 1000 240 G9.5 23000 150 T6 12 15
FER 54571 FER Stage & Studio 1000 120 RX7s 27500 500 T6 12
FEV 54441 FEV Stage & Studio 200 120 BA15d 5500 50 T4 12
FEX/230 54514 FEX/230 64781 Stage & Studio 2000 230 RX7s 50000 300 T8 12 12
FEX/240 54518 FEX/240 64781 Stage & Studio 2000 240 RX7s 50000 300 T8 12
FEY 54559 FEY Stage & Studio 2000 120 RX7s 57400 400 T8 12
FFJ 54488 FFJ Stage & Studio 600 120 R7s 16500 75 T4 24 14
FFM 58862 FFM Stage & Studio 420 120 R7s 11000 75 T4 24 14
FFT 54350 FFT Stage & Studio 1000 120 R7s 27000 300 T3 12
FHM 54532 FHM Stage & Studio 1000 120 R7s 27300 300 T3 12
FKW 54711 FKW Stage & Studio 300 120 GY9.5 7800 200 T6 24
FLK 54589 FLK Stage & Studio 575 115 G9.5 16500 300 T5 12 16
FMR 54412 FMR Stage & Studio 600 120 GY9.5 12500 2000 T5 24
FRG 54629 FRG Stage & Studio 500 120 GY9.5 13000 150 T6 24
FRK 54631 FRK Stage & Studio 650 120 GY9.5 16900 200 T6 24
FSH 54436 FSH Projector, Stage & 125 120 G5.3 2500 200 T3 24
Studio
FTK 54875 FTK Stage & Studio 500 120 GY9.5 12000 200 T6 24
FVL 54459 FVL Stage & Studio 200 120 GX5.3 5200 200 T4 24
FVM 54434 FVM Stage & Studio 105 120 GX5.3 2250 250 T4 24
GCA 54428 GCA Projector - Video, 250 120 G5.3 5700 200 T3 24
Studio
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
178
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
STUDIO, THEATRE, TV & VIDEO
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
GKV 54511 GKV Stage & Studio 600 230 G9.5 14000 300 T6 25 5
GLA 54516 GLA 575/115/2000 Stage & Studio 575 115 G9.5 10500 2000 T6 12 17
GLC 54507 GLC 575/115/300 Stage & Studio 575 115 G9.5 15500 300 T6 12 17,18
GLF 54460 GLF Stage & Studio 235 230 G5.3 5100 100 T4 24
20607 STUDIOLINE 55W/3200 Compact Fluorecent 55 2G11 3800 8000 T5 10
/Studio-TV
20608 STUDIOLINE 55W/5600 Compact Fluorecent 55 2G11 3800 8000 T5 10
/Studio-TV
54001 64501 Stage & Studio 150 120 GX6.35 4500 25 T4 25
54232 64614 Projector, Video, 75 12 G5.3-4.8 25 T2.5 20
Studio
54499 4515 PAR36 30W Stage & Studio 30 6 Screw Term 67000 100 PAR36 12
54549 HPR 575/115 Stage & Studio 575 115 G9.5 18000 300 T5 12 16
54602 HPL750/115 (UCF) Stage & Studio 750 115 21900 300 T6 12 19
54603 HPL750/230 (UCF) Stage & Studio 750 230 Special 19750 300 T6 12 19
54604 HPL550/77/X (UCF) Stage & Studio 550 77 12160 2000 T6 12 19
54605 HPL750/120 (UCF) Stage & Studio 750 120 Special 21900 300 T6 12 19
54611 HPL750/115/X (UCF) Stage & Studio 750 115 16400 1500 T6 12 19
54614 HPL750/240 (UCF) Stage & Studio 750 240 Special 19750 300 T6 12 19
54618 HPL575/230 (UCF) Stage & Studio 575 230 Special 14900 400 T6 12 19
54619 HPL575/240 (UCF) Stage & Studio 575 240 Special 14900 400 T6 12 19
54622 HPL575/115 (UCF) Stage & Studio 575 115 16520 300 T6 12 19
54623 HPL550/77 (UCF) Stage & Studio 550 77 16170 300 T6 12 19
54625 HPL375/115 (UCF) Stage & Studio 375 115 10540 300 T6 12 19
54649 HPL375/115/X (UCF) Stage & Studio 375 115 8000 1000 T8 12 19
54653 HPL750/120/X (UCF) Stage & Studio 750 120 Special 16400 1500 T6 12 19
54807 HPL575/115/X (UCF) Stage & Studio 575 115 12360 2000 T6 12 19
54813 HPL550/64 (UCF) Stage & Studio 550 64 Special 16340 300 T6 12 19
54815 HPL575/120/X (UCF) Stage & Studio 575 120 Special 12360 2000 T6 12 19
54817 HPL575/120 (UCF) Stage & Studio 575 120 Special 16460 300 T6 12 19
54822 HPL575/100 (UCF) Stage & Studio 575 100 Special 16730 300 T6 12 19
54825 HPL750/77 (UCF) Stage & Studio 750 77 22950 300 T6 12 19
58636 64515 Stage & Studio 300 230 GX6.35 8500 15 T5 25 12
58639 64573 Stage & Studio 1000 120 GX6.35 33000 15 T8 25
58640 64575 Stage & Studio 1000 230 GX6.35 33000 15 T8 25 12
LARGE PAR
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
EXC/230 56280 EXC/230 Stage & Studio 1000 230 Ext Mog End Pr 300 PAR64 6 20,21
EXC/240 56232 EXC/240 Stage & Studio 1000 240 Ext Mog End Pr 300 PAR64 6 20,21
EXD/230 56281 EXD/230 Stage & Studio 1000 230 Ext Mog End Pr 300 PAR64 6 20
EXD/240 56233 EXD/240 Stage & Studio 1000 240 Ext Mog End Pr 300 PAR64 6 20
EXE/230 56283 EXE/230 Stage & Studio 1000 230 Ext Mog End Pr 300 PAR64 6 20
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
179
STUDIO, THEATRE, TV & VIDEO
LARGE PAR
11 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Application Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
EXE/240 56234 EXE/240 Stage & Studio 1000 240 Ext Mog End Pr 300 PAR64 6 20
EXG 56282 EXG/230 Stage & Studio 1000 230 Ext Mog End Pr 300 PAR64 6 20,22
FFN 56214 FFN Stage & Studio 1000 120 Ext Mog End Pr 800 PAR64 6 20,23
FFP 56215 FFP Stage & Studio 1000 120 Ext Mog End Pr 800 PAR64 6 20,21
FFR 56217 FFR Stage & Studio 1000 120 Ext Mog End Pr 800 PAR64 6 20,24
FFS 56216 FFS Stage & Studio 1000 120 Ext Mog End Pr 800 PAR64 6 20,22
14974 350PAR56/SP Train Ditch Light 350 75 MEP 750 PAR56 12 20
SPECIAL PURPOSE HEAT LAMPS
12 Avg
|
Product Rated Pkg
|
ANSI Code Number Ordering Abbreviation Watts Volts Base Lumens Life(hrs) Bulb Qty Footnotes
|
FRN 54588 FRN 2000T8Q 2000 120 G9.5 56500 200 T8 12 25,26
54007 64514 300 120 GX6.35 7700 75 T6 25 25,26
54008 64516/300T6/CL 300 230 GX6.35 7300 75 T6 25 12,25,26
54546 750/120/T5/RTP 750 120 G9.5 15400 2000 T5 15 25,26
54560 1000TQ/RTP/CR/BULK 1000 120 G9.5 25000 2000 T6 15 25,26,27
54584 1000Q/T6/RTPFS 1000 120 G9.5 27500 300 T6 12 25,26
54633 1500Q/T6/RTPGS 1500 120 G9.5 42000 300 T6 12
54752 1000T6QRTP/X 1000 120 G9.5 25000 2000 T6 12
59803 2500T3Q/IR/7 480V 2500 480 RSC 5000 T3 12 25,26,28
59822 500T3Q/IR/7 120V 500 120 RSC 5000 T3 12 25,26,28
59841 1600T3Q/IR/7 240V 1600 240 RSC 5000 T3 12 25,26,28
59850 500T3Q/IR 120V 500 120 Flex Nickel Leads 5000 T3 12 25,26,28
59859 3650T3Q/IR/CL 480V 3650 480 Flex Nickel Leads 5000 T3 12 25,26,28
59860 1000T3Q/IR 230-250V 1000 240 Flex Nickel Leads 5000 T3 12 25,26,28
59864 1600T3Q/IR 240V 1600 240 Flex Nickel Leads 5000 T3 12 25,26,28
59867 2500T3Q/IR 480V 2500 480 Flex Nickel Leads 5000 T3 12 25,26,28
59870 3800T3Q/IR 570V 3800 570 Flex Nickel Leads 5000 T3 12 25,26,28
59934 1200T3Q/IR/CL/HT 144V 1200 144 Flex Nickel Leads 3000 T3 12 25,28,29,30
59936 1600T3Q/IR 277V 1600 277 Flex Nickel Leads 5000 T3 12 25,26,28
AIRCRAFT
13 Avg
|
Product Beam Rated MOL Pkg
|
Watts Bulb Volts Base Number Ordering Abbreviation Application Type CBCP Filament Life(hrs) (mm) Qty Footnotes
|
100 T3 12 PG22 54032 64621 HLX Projector, Microfilm, 2000 48 30
Stage & Studio, Aircraft
250 PAR46 28 Screw Term 15399 4551 Aircraft Taxiing VNSP 75000 CC-6 25 95.25 12 23
450 PAR46 28 Screw Term 56229 Q4681 Aircraft Landing / VNSP 310000 CC-6 50 63.5 12 20,23
Taxiway
600 PAR64 28 Screw Term 14936 4559 Aircraft Landing / VNSP 600000 CC-8 25 101.6 6 23
Taxiway
56222 Q4559 Aircraft Landing / VNSP 600000 CC-8 100 101.6 6 20,23
Taxiway
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
180
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
AIRCRAFT
13 Avg
|
Product Beam Rated MOL Pkg
|
Watts Bulb Volts Base Number Ordering Abbreviation Application Type CBCP Filament Life(hrs) (mm) Qty Footnotes
|
600 PAR64 28 Screw Term 56223 Q4559X Aircraft Landing / VNSP 765000 CC-8 100 101.6 6 20,23
Taxiway
1000 PAR64 28 Screw Term 14988 4557 Aircraft VNSP 540000 CC-8 25 101.6 6 23
Landing/Taxiway
14994 5557 Aircraft VNSP 540000 CC-8 50 101.6 6 23,31
Landing/Taxiway
AIRFIELD
14 Avg
|
Product Current Rated LCL MOL Pkg
|
Watts Bulb Base Number Ordering Abbreviation Application (A) Lumens Filament Life(hrs) (mm) (mm) Qty Footnotes
|
30 MR16 Special 58537 6.6A/30MR16/64331A/SP Airfield/Airport 6.6 10
58730 6.6A/30MR16/64331AC/FL Airfield / Airport 6.6 1000 10 32
T3.5 GZ9.5 58779 6.6A/30T3.5/64322/EXL/DL Airfield/Airport 6.6 400 C-8 2000 16 58 30
T10 Med Prefocus 17980 6.6A/30T10/1P Airfield/Airport 6.6 400 C-2V 1000 38.1 100 60
40 MR11 PK30d 58787 6.6A/40MR11/64333B Airfield / Airport 6.6 1500 10 33
45 MR16 Special 58545 6.6A/45MR16/64337A45-15 Airfield / Airport 6.6 19000 1500 10
PK30d 58758 6.6A/45MR16/64337B45-15 Airfield / Airport 6.6 1500 10 33
T3 R7s 58704 6.6A/45T3/CL/64315 Airfield/Airport 6.6 750 C-8 1000 23 47.5 25
T3.5 GZ9.5 58775 6.6A/45T3.5/64320/EXM Airfield/Airport 6.6 875 C-8 1000 25.4 44.5 100
G6.35 58813 6.6A/45T3.5Q/64321 Airfield / Airport 6.6 840 C-8 1200 33 50 100
T4 PK30d 58697 6.6A/45T4/64319 FEMALE Airfield/Airport 6.6 800 C-8 1000 20 53 100 34,35
58705 6.6A/45T4/CL/64317 Airfield/Airport 6.6 800 C-8 1000 16 58 100 35
Special 58722 6.6A/45T4/64319Z Airfield/Airport 6.6 800 C-8 1000 20 53 100 36,37
T10 Med Prefocus 17981 6.6A/45T10/P Airfield/Airport 6.6 675 C-2V 1000 38.1 100 60
48 MR16 Special 58711 6.6A/48MR16/64338AC Airfield / Airport 6.6 1000 10
58792 6.6A/48MR16/64337A48-15 Airfield/Airport 6.6 20000 1500 10 35
65 T4 Special 58726 6.6A/65T4/64328Z/HLX Airfield/Airport 6.6 1450 C Bar 6 1000 20 53 100 37,38
100 T4 Special 58703 6.6A/100T4/64341Z/HLX Airfield/Airport 6.6 2700 C Bar 6 1000 20 55 100 37,39
PK30d 58706 6.6A/100T4/64342/HLX Airfield/Airport 6.6 2700 C Bar 6 1000 20 58 100 35
58709 6.6A/100T4/64341/HLX Airfield/Airport 6.6 C Bar 6 1000 20 55 100 35
105 MR16 PK30d 58759 6.6A/105MR16/64339B Airfield/Airport 6.6 1000 10 33
58785 6.6A/105MR16/64339A Airfield / Airport 6.6 1000 10 35
Special 58816 6.6A/105MR16/64339C Airfield / Airport 6.6 1000 10 37
115 T4 GY9.5 58794 6.6A/115T4Q/58798/2PPF/EVV Airfield/Airport 6.6 2900 C Bar 6 1000 39.1 57 30 40,41
DCR 58819 6.6A/115T4Q/DCR/DL Airfield/Airport 6.6 C Bar 6 1000 26.9 60.3 100
150 T4 PK30d 58717 6.6A/150T4/64361/HLX Airfield/Airport 6.6 3600 C Bar 6 1000 20 58 100 35,42
Special 58724 6.6A/150T4Q/64361Z/HLX Airfield/Airport 6.6 3600 C Bar 6 1000 20 58 100 37
GY9.5 58777 6.6A/150T4Q/64354/EWR/DL Airfield/Airport 6.6 4000 C Bar 6 1500 39.1 65 30 40,41
175 T4 GY9.5 58795 6.6A/175T4Q/58799/2PPF/DL Airfield/Airport 6.6 4700 C Bar 6 1000 39.1 57 30 41,43
200 PAR64 Ext Mog End Pr 14985 6.6A/200PAR64/2 Airfield/Airport 6.6 CC-6 1000 114.3 6
56220 6.6A/200PAR64Q/2P Airfield/Airport 6.6 CC-6 2000 114.3 6 20,44
T4 PK30d 58649 6.6A/200T4/64382A/HLX Airfield/Airport 6.6 4800 CC-6 1000 20 64 100
Special 58708 6.6A/200T4/64382/HLX Airfield/Airport 6.6 4800 CC-6 1000 20 64 100 45
GY9.5 58789 6.6A/200T4Q/2PPF/58750/EZL/DL Airfield/Airport 6.6 5200 CC-6 1000 39.1 57.0 30 40,41
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
181
AIRFIELD
14 Avg
|
Product Current Rated LCL MOL Pkg
|
Watts Bulb Base Number Ordering Abbreviation Application (A) Lumens Filament Life(hrs) (mm) (mm) Qty Footnotes
|
200 T4 G6.35 58815 6.6A/200T4Q/64386 Airfield / Airport 6.6 4700 C Bar 6 1200 33 47 100
DCR 58821 6.6A/200T4Q/CL/DCR/DL Airfield/Airport 6.6 5000 CC-6 1000 27 80.9 100
T5 R7s 58707 6.6A/200T5/CL/64380 Airfield/Airport 6.6 4400 CC-8 1000 21.3 60.2 25
204 T14 Med Prefocus 17983 6.6A/204T14/2P Airfield/Airport 6.6 4220 C-13 500 55.5 146 24
P
H
O
T
O
O
P
T
I
C
H
A
L
O
G
E
N
HMI 1200 W/SE
54067
1200
100
13.8
110000
6000
200
107
42
10
750
Any
G38
Yes
6
4
HMI 123 W
54059
125
80
1.7
8500
6000
64
26.7
10
4
150
Any
Special
Yes
1
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 4000 W/SE
54072
4000
200
24.0
380000
6000
250
142
75
20
500
Any
G38
Yes
7
4
HMI 250 W/SE
54062
270
50
5.0
16200
6000
84
35
12
5
250
p 45
FaX1.5
Yes
3
1,2,3
HMI 12000 W/SE
54113
12000
160
84
1150000
6000
450
255
100
27
300
s 135
GX38
Yes
8
4,5,6
HMI 575 W/SE
54063
575
95
7.0
49000
6000
145
70
30
7
750
Any
G22
Yes
5
4
HMI 2500 W/SE
54070
2500
115
25.6
240000
6000
225
127
60
14
500
Any
G38
Yes
7
4
HMI 200 W/SE
54061
200
70
3.0
16000
6000
80
39
20
5
200
Any
GZY9.5
Yes
2
1
HMI®METAL HALIDE
HMI 6000 W/SE
54099
6000
123
55
600000
6000
360
210
75
23
500
s 135
GX38
Yes
8
4,5,6
HMI 400 W/SE
54137
400
70
6.9
33000
6000
110
60
23
6
650
Any
GZZ9.5
Yes
4
4
123456 7 8
HMI®SINGLE-ENDED
HMI®SINGLE-ENDED
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
182
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HMI 2500 W/S
54068
2500
115
25.6
240000
6000
210
150
31.5
14
500
p 30
SFa21
Yes
4
4,8,9
HMI 200 W
54060
200
80
3.1
14000
6000
75
60
14
10
300
p 15
X515
Yes
1
4
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l1max (mm)
Length l2max (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l1max (mm)
Length l2max (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMI 6000 W
54073
6000
123
55.0
570000
6000
450
54
21
500
p 15
S25.5
Yes
5
4
HMI 1200 W/GS
54066
1200
100
13.8
110000
6000
220
180
27
10
750
Any
SFc15.5
Yes
3
4,7
HMI 18000 W
54075
18000
225
88.0
1700000
6000
500
70
44
250
p 15
S30
Yes
5
4,10
HMI 2500 W/GS
54069
2500
115
25.6
240000
6000
355
290
31.5
14
500
p 30
SFa21
Yes
4
4,7
HMI 4000 W
54071
4000
200
24.0
380000
6000
405
340
36
34
500
p 15
SFa21
Yes
4
4,10
HMI 575 W/GS
54098
575
95
7.0
49000
6000
135
115
21
7
1000
Any
SFc10-4
Yes
2
4,7
HMI®METAL HALIDE
HMI 12000 W/GS
54074
12000
160
84.0
1150000
6000
470
64
25
500
p 15
S30
Yes
5
4,7
HMI 1200 W/S
54088
1200
100
13.8
110000
6000
135
115
21
7
750
Any
SFc10-4
Yes
2
4,8,9
12 3
45
HMI®DOUBLE-ENDED
HMI®DOUBLE-ENDED
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
183
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HMP 400 DE
54146
400
100
4.8
33000
6000
92
35
16
5.5
750
p 45
SFXc10-4
Yes
2
4,12,13
HMP 575 SE
54145
575
100
6.7
49000
6000
145
70
30
7
1000
Any
G22
Yes
1
4,11
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HMP 575 DE
54144
575
100
6.7
49000
6000
135
57.5
21.5
7
1000
Any
SFXc10-4
Yes
3
4,11
HMP®METAL HALIDE
12 3
HMP®DOUBLE-ENDED
HMP®SINGLE-ENDED
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
184
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HTI 250 W/SE
54091
270
45
6
10000
40000
4900
80
35
2.5
250
p 45
FaX1.5
Yes
4
1,2,3,15
HTI S 35/12
69000
35
85
2.5
3200
6500
4250
79.5
27.1
4.2
3000
p 10
P32d-2
Yes
1
1,2
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 404 W/SE
54106
400
55
7.3
28000
40000
6000
84
35
3.0
500
p 45
FaX1.5
Yes
4
1,15,16
HTI 152 W
54079
150
95
1.8
9500
4200
5000
48
30
6.75
2000
Any
GY9.5
No
3
4
HTI 400 W/SE
54084
400
55
7.3
28000
30000
4800
84
35
4.0
250
p 45
FaX1.5
Yes
4
1,2,3,15,16,17,18
HTI 150 W
54078
150
90
1.8
9500
5000
6500
46
30
5.0
750
Any
GY9.5
No
2
4,14
HTI®METAL HALIDE
1234
HTI®SINGLE-ENDED
HTI®SINGLE-ENDED
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
185
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HTI 1200 W/SE
54141
1200
100
13.8
99000
26000
4500
135
59
7
600
s 135
GY22
Yes
3
4,6,15,19
HTI 405 W/SE
54139
400
55
7.3
28000
40000
5800
80
36.5
3.0
500
p 45
GY9.5
No
1
1,2,6,15,17,18
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 705 W/SE
54130
700
70
10
59000
5700
85
39
4
500
p 45
GY9.5
No
1
6,15
HTI 2500 W/SE
54142
2500
115
25.6
240000
30000
6000
180
85
14
600
s 135
G22+Cable
Yes
4
4,6,20
HTI 600 W/SE
54087
600
95
7.7
48000
25000
5300
84
35
5.5
300
p 45
FaX1.5
Yes
2
3,4,15,16
HTI®METAL HALIDE
12 3 4
HTI®SINGLE-ENDED
HTI®SINGLE-ENDED
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
186
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HTI 250 W/22
54080
270
45
6
5600
73
22
67
2.5
250
P 20
Yes
4
1
HTI 300 W/DEL
54112
300
85
4.3
20000
5700
92
70
16
5.5
3000
p 45
SFc10-4
Yes
1
4
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Color Temp (K)
Length l max (mm)
Working Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HTI 250 W/32C
54089
270
45
6
5600
73
32
67
2.5
250
P 20
Yes
5
4
HTI 600 W/D
54140
600
95
7.7
48000
25000
5300
75
59
16
5.5
300
p 45
Special
Yes
2
4
HTI 403 W/24
54104
400
55
7.3
5600
73
24
67
4.0
750
P 20
YES
5
1
HTI 4000 W/DE
54133
4000
115
39.0
360000
35000
6300
270
140
40
15
500
p 30
S25.5
Yes
3
4
HTI 250 W/32
54081
270
45
6
5600
73
32
67
2.5
250
P 20
Yes
4
1,22
HTI 300 W/DX
54143
300
100
3.6
22000
20000
6500
92
70
16
5.5
750
p 45
SFc10-4
Yes
1
4,21
HTI®METAL HALIDE
HTI 400 W/24
54083
400
55
7.3
5600
73
24
67
4.0
250
P 20
Yes
5
1
HTI 700 W/DE
54117
700
73
10
59000
5600
135
115
18
4
750
Any
Special
Yes
1
4,6
1
23 4 5
HTI®WITH DICHROIC REFLECTOR
HTI®DOUBLE-ENDED
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
187
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HSR 700/60
54107
700
72
11
58000
10000
6000
155
75
30
8
1000
Any
G22
No
2
4
HSR 400/60
54102
400
67
6.9
33000
20000
5900
110
62
23
5
650
Any
GX9.5
No
1
4
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HSR 575/72
54116
575
95
7
49000
10000
7200
125
65
30
7
1000
Any
GX9.5
No
1
4
HSR 1200/60
54168
1200
100
13.8
110000
20000
6000
175
85
40
10
1000
Any
G22
No
2
4
HSR 575/60
54115
575
95
7
49000
10000
6000
125
65
30
7
1000
Any
GX9.5
No
1
4
HSR®METAL HALIDE
12
HSR®WITH OUTER JACKET
HSR®WITH OUTER JACKET
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
188
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HSD 150/70
54119
150
97
1.8
12000
7000
105
56
20
5.5
2000
Any
G12
No
1
4,23
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap - cold (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
HSD 250/60
54170
250
90
3.1
17000
6000
110
55
23
5
2000
Any
GY9.5
No
2
4,24
HSD 575/72
54129
575
88
7.4
45000
7200
135
65
30
7
3000
Any
GX9.5
No
2
4
HSD 200/60
54167
200
70
3.3
13000
6000
108
55
23
5
2000
Any
GY9.5
No
2
4
HSD®METAL HALIDE
HSD 250/78
54118
250
90
3.1
17000
7800
108
55
23
5
3000
Any
GY9.5
No
2
4
12
HSD®WITH OUTER JACKET
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
189
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
VIP S 170/13
69320
170
85
2.0
11900
30000
9000
62
35
13
5
4000
Horizontal, tip-off up
SFc10-4
Yes
1
1,25
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Current (A)
Lumens (lm)
Average Luminance (cd/cm2)
Color Temp (K)
Length l (mm)
Distance a (mm)
Diameter d (mm)
Arc Length (mm)
Avg Rated Life (hrs)
Operating Position
Base
Hot Restart
Fig No
Symbols & Footnotes
VIP R 273/45
69327
270
38
7.1
17000
100000
5800
73
45
67
1.9
1000
Horizontal, tip-off up
Yes
2
1,25,26
VIP®VIDEO AND DATA PROJECTION
12
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
190
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 75 W/2
69231
75
14
DC
5.4
1000
100
40000
0.25 x 0.5
90
82
43
10
400
400
s 105
SFa9-2
SFa7.5-2
1
27,28,29,30
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 100 W OFR
69233
100
14
DC
7.0
1900
270
31000
0.4 x 0.8
90
82
44.5
11
500
s 105
Required
SFa9-2
SFa7.5-2
1
29,30,31
XBO R 100 W/45C OFR
69191
100
13
DC
7.0
0.4 x .09
83
75
67
500
p 15
Required
3
28,29,30,31,34
XBO 75 W/2 OFR
69232
75
14
DC
5.4
1000
100
40000
0.25 x 0.5
90
82
43
10
400
400
s 105
SFa7.5-2
SFa7.5-2
1
28,29,30,31
XBO®<= 450W XENON SHORT ARC
XBO R 100 W/45 OFR
69197
100
13
DC
7.0
0.4 x 0.9
83
75
67
500
p 15
Required
2
28,29,31,32,33,34
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
191
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
192
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO R 101 W/45C OFR
69190
100
13
DC
7.0
83
75
67
500
p 15
Required
1
28,31,34,35,36
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 150 W/1 OFR
69235
150
20
DC
7.5
3000
300
15000
0.5 x 2.2
150
127
57
1200
s 15
Required
SFc12-4
SFcX12-4
2
28,29,30,31,38
XBO 150 W/1
69234
150
20
DC
7.5
3000
300
15000
0.5 x 2.2
150
127
57
20
1200
s 15
Required
SFc12-4
SFcX12-4
2
28,29,30,37,38
XBO®<= 450W XENON SHORT ARC
XBO 150 W/4
69238
150
20
DC
7.5
3000
300
15000
0.5 x 2.2
150
127
57
20
1200
s 15
Required
SFc12-4
SFcX12.4
2
28,29,30,39
12
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
193
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 150 W/CR OFR
69237
150
18
DC
8.5
2900
290
20000
0.5 x 1.6
150
127
57
20
3000
1200
s15 p15
Required
SFc12-4
SFcX12-4
1
28,29,30,31,40,41
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO R 180 W/45/OFR
69186
180
14
DC
12
90
75
67
500
p 15
Required
3
28,29,30,31,34,42
XBO 150 W/S
69236
150
20
DC
7.5
2200
220
18000
0.5 x 1.9
117
96
47.5
20
1000
800
s15 p15
Required
SFa12-11
SFa12-11
2
8,28,29,30,40
XBO®<= 450W XENON SHORT ARC
XBO R 180 W/45C OFR
69183
180
14
DC
12
90
75
67
500
p 15
Required
4
28,29,30,31,34,35
123 4
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
194
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO R 181 W/45C OFR
69184
180
14
DC
12
90
75
67
500
p 15
Required
1
28,29,30,31,34,35,36
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO R 300 W/60C OFR
69167
300
17
DC
16
14 - 19
62
30
60
82.5
1000
p20
Required
3
28,29,30,31,35,43
XBO 250 W OFR
69239
250
13
DC
18
14-20
4800
530
26000
0.7 x 1.7
226
192
93
25
1200
s 15
Required
SFa16-8
SFa16-10
2
28,29,30,31
XBO®<= 450W XENON SHORT ARC
XBO 450 W
69241
450
17
DC
25
17-30
13000
1300
35000
0.9 x 2.7
260
212
95.5
29
2000
s 30
Required
SFa20-8
SFa20-10
2
28,29,30,44,45
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
195
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 450 W OFR
69245
450
17
DC
25
17-30
13000
1300
35000
0.9 x 2.7
260
212
95.5
29
2000
s 30
Required
SFa20-8
SFa20-10
1
28,29,30,31
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 450 W/2 OFR
69243
450
17
DC
25
17-30
13000
1300
35000
0.9 X 2.7
177
79
29
2000
s 30
Required
SK19/36
SK19/36
2
28,29,30,31
XBO 450 W/1
69242
450
17
DC
25
17-30
13000
1300
45000
0.7 x 2.2
260
212
95.5
29
800
800
s 100
Required
SFa20-8
SFa20-10
1
28,29,30
XBO®<= 450W XENON SHORT ARC
XBO 450 W/4
69244
450
17
DC
25
17-30
13000
1300
35000
0.9 x 2.7
260
212
95.5
29
2000
s 30
Required
SFa20-8
SFa20-10
1
28,29,30,39
12
XBO 500 W/H OFR
69257
500
17
DC
28
17-30
14500
1450
40000
0.9 x 2.5
190
165
75
35
2000
2000
s30 p30
Required
Required
SFa16-8
SFa15-10
1
2,28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 900 W OFR
69261
900
19
DC
45
30-53
30000
3000
50000
1.1 x 3.3
325
277
123
40
2400
s 30
Required
SFa25-10
SFa25-12
3
28,29,30,31,46
XBO 1000 W/HSC OFR
69264
1000
19
DC
50
30-55
32000
3000
60000
1.1 x 2.8
236
222
95
40
2000
2000
s20 p20
Required
SK27/50
SFcX27-8
5
2,8,28,29,30,31,35,46
XBO 700 W/HS OFR
69260
700
18
DC
37
30-45
20000
2000
40000
1.1 x 2.9
235
205
95
40
1500
1500
s20 p20
Required
SFa27-11
SFcX27-8
2
2,8,28,29,30,31,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 1000 W/HS OFR
69263
1000
19
DC
50
30-55
32000
3000
60000
1.1 x 2.8
235
205
95
40
2000
2000
s20 p20
Required
SFa27-11
SFcX27-8
4
2,8,28,29,30,31,46
12 3 4 5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
196
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 1000 W/HTP OFR
69265
1000
21
DC
45
30-55
35000
3200
45000
1.0 x 4.0
330
277
123
46
2400
2400
s30 p30
Required
SFa25-14
SFc25-14
1
2,28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 1600 W/HSC OFR
69269
1550
23
DC
65
50-70
60000
5500
70000
1.0 x 3.2
236
222
95
46
2000
2000
s20 p20
Required
SK27/50
SFcX27-8
3
2,8,28,29,30,31,35,46
XBO 1600 W/CA OFR
69267
1600
24
DC
65
45-75
60000
6000
65000
1.4 x 4.0
370
322
143
52
2400
s 30
Required
SFaX27-10
SFa27-12
5
28,29,30,31,46,47
XBO 1600 W/HS OFR
69268
1550
23
DC
65
50-70
70000
5500
70000
1.0 x 3.2
235
205
95
46
2000
2000
s20 p20
Required
SFa27-11
SFcX27-8
2
2,8,28,29,30,31,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 1600 W OFR
69266
1600
24
DC
65
45-75
60000
6000
65000
1.4 x 4.0
370
322
142.5
52
2400
s 30
Required
SFa27-10
SFa27-12
4
28,29,30,31,46
123 45
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
197
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 2000 W/H OFR
69258
2000
28
DC
70
50-85
80000
7500
80000
1.3 x 4.8
370
322
142.5
52
2400
2400
s30 p30
Required
Required
SFaX27-10
SFaX27-12
1
2,28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 2000 W/HTP OFR
69247
2000
27
DC
70
50-85
80000
7500
75000
1.3 x 4.8
375
322
142.5
52
2400
2400
s30 p30
Required
SFa25-14
SFc25-14
3
2,28,29,30,31,46,
48,49
XBO 2001 W/HTP OFR
69310
2000
25
DC
80
50-85
80000
7500
75000
1.3 x 4.8
375
322
142.5
52
2400
2400
s30 p30
Required
Required
SFa25-14
SFc25-14
5
2,28,29,30,31,40,46,
48,49
XBO 2000 W/HS OFR
69270
2000
25
DC
80
50-85
80000
7500
80000
1.3 x 4.0
342
302
145
60
2400
2400
s30 p30
Required
SFaX27-9.5
SFa27-7.9
2
2,8,28,29,30,31,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 2000 W/SHSC OFR
69256
2000
26
DC
70
50-85
80000
7500
80000
1.3 x 4.0
236
222
95
46
2400
2400
s20 p20
Required
SK27/50
SFcX27-8
4
2,28,29,30,31,35,46,
50,51
12345
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
198
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 2500 W OFR
69248
2500
29
DC
85
60-95
100000
9500
60000
1.5 x 6.0
428
382
167.5
60
2000
s 30
SFaX27-13
SFaX27-14
1
28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 3000 W/H OFR
69251
3000
30
DC
100
60-110
130000
12000
90000
1.7 x 5.0
428
382
167.5
66
1800
1500
s30 p30
Required
Required
SFaX27-13
SFa27-14
2
2,28,29,30,31,46
XBO 3000 W/HTP OFR
69252
3000
30
DC
100
60-110
130000
12000
85000
1.7 x 5.0
405
357
162.5
66
1800
1500
s30 p30
Required
Required
SFa27-14
SFc27-14
3
2,28,29,30,31,46,48
XBO 2500 W/HS OFR
69249
2500
26
DC
90
70-100
100000
10000
80000
1.5 x 4.5
342
302
145
60
1800
1500
s30 p20
Required
SFaX27-9.5
SFa27-7.9
2
2,8,28,29,30,31,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 3000 W/HS OFR
69250
3000
30
DC
100
60-110
130000
12000
90000
1.7 x 5.0
342
302
145
60
1800
1500
s30 p30
Required
SFaX27-9.5
SFa27-7.9
2
2,8,28,29,30,31,46
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
199
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 4000 W OFR
69253
4000
32
DC
120
80-140
180000
19000
70000
2.0 x 7.5
432
384
176
60
1000
s 15
Required
SFa30-18
SFa30-20
1
28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 4000 W/HTP OFR
69296
4000
31
DC
130
100-140
155000
16000
90000
1.9 x 6.0
433
382
167.5
70
1200
1200
s20 p20
Required
SFa27-14
SFc27-14
3
2,28,29,30,31,46,48
XBO 4200 W/GS OFR
69350
4200
29
DC
140
80-160
190000
20000
100000
2.1 x 5.7
428
382
167.5
60
500
500
s 15
Required
SFaX27-13
SFaX27-14
4
7,28,29,30,31,46
XBO 4000 W/HS OFR
69254
4000
28
DC
135
80-150
155000
17000
90000
1.9 x 6.0
410
370
171
70
1000
1000
s20 p20
Required
SFaX30-9.5
SFa30-7.9
2
2,8,28,29,30,31,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 4200 W/CA OFR
69294
4200
29
DC
140
80-160
190000
20000
100000
2.1 x 5.7
428
382
167.5
70
1000
s 15
Required
SFaX27-13
SFaX27-14
4
28,29,30,31,46,47,52
12 34
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
200
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
201
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 4500 W/HS
69359
4500
32
DC
135
80-150
200000
20000
120000
1.8 x 6.0
410
370
171
70
1000
1000
s15 p15
Required
Required
SFa30-7.9
SFaX30-9.5
1
28,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 5000 W/H OFR
69315
5000
34
DC
140
100-150
225000
27000
95000
2.2 x 6.5
433
382
168
70
1000
1000
s15 p15
Required
Required
SFaX30-16
SFa28-18
2
2,28,29,30,31,46
XBO 4500 W/HTP
69360
4500
32
DC
135
100-150
200000
20000
120000
1.8 x 6.0
433
370
171
70
1000
1000
s15 p15
Required
Required
SFa27-14
SFc27-14
3
28,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 5000 W/HTP OFR
69336
5000
35
DC
140
100-150
225000
22000
95000
2.2 x 6.5
433
382
165
70
1000
1000
s15 p15
Required
Required
SFa27-14
SFc27-14
3
2,28,29,30,31,46,48
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
202
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 6000 W/HS OFR
69339
6000
37
DC
160
110 - 165
300000
28000
105000
2.0 x 7.5
433
393
170.5
78
600
600
s15 p15
Required
SFaX30-9.5
SFa30-7.9
1
2,8,28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 6500 W
69298
6500
40
DC
160
80-160
325000
32000
95000
2.3 x 9.0
483
434
200
60
500
s 10
Required
SFa30-20
SFa30-22
3
28,29,30,46
XBO 6000 W/HTP OFR
69340
6000
37
DC
160
110 - 165
280000
28000
105000
2.0 x 7.5
433
382
165
78
600
600
s15 p15
Required
Required
SFa30-14
SFc30-14
2
2,8,29,30,31,46,53,54
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 7000 W/HS OFR
69295
7000
42
DC
160
110-165
350000
35000
100000
2.0 x 7.5
433
393
170.5
78
500
500
s15 p15
Required
Required
SFaX30-9.5
SFa30-8.0
3
2,28,29,30,31,46
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
203
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
XBO 7000 W/HSH OFR
69301
7000
43
DC
160
110-165
350000
35000
110000
2.0 x 7.5
433
393
170.5
78
500
500
s 15, p15
Required
Required
SFaX 30-9.5
SFa30-7.9
1
2,28,29,30,31,46
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Current Control Range (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area -- w x h (mm)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life Vertical (hrs)
Avg Rated Life Horizontal (hrs)
Operating Position
Forced Cooling
Magnetic Arc Stabilization
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
XBO 10000 W/C OFR
69297
9600
59
DC
160
110-170
500000
47500
80000
2.7 x 14.0
483
434
200
78
500
s 15
Required
SK30-20
SFa30-22
2
28,29,30,31,35,46,55
XBO 8000 W/HS OFR
69351
8000
45
DC
175
150-180
400000
40000
110000
2.3 x 10.5
433
393
170.5
90
500
500
s 15, p15
Required
Required
SFaX 30-9.5
SFa 30-7.9
1
2,28,29,30,31,46
XBO®>450W XENON SHORT ARC CINEMA FILM PROJECTION
XBO 10000 W/HS OFR
69342
10000
51
DC
195
160-200
500000
45000
90000
2.4 x 12.0
433
393
170.5
90
500
500
s15 p15
Required
Required
SfaX 30-9.5
SFa30-7.9
2
2,28,29,30,31,46
12
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
204
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 50 W AC L1
69213
50
37
AC
1.45
2000
230
30000
0.3 x 1.0
40
53
47
22
8.5
100
s 45, anode down
Convection
SFa6-2
SFa6-2
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 50 W/3
69215
50
23
DC
2.3
1300
150
90000
0.2 x 0.35
26
53
47
22
9
200
s 45, anode down
Convection
SFa6-2
SFa8-2
2
HBO 50 W AC L2
69214
50
42
AC
1.3
2000
230
30000
0.3 x 1.0
40
53
47
22
8.5
100
s 45, anode down
Convection
SFa6-2
SFa6-2
1
HBO®MERCURY SHORT ARC
HBO 100 W/2
69217
100
20
DC
5.0
2200
260
170000
0.25 x 0.25
22
90
82
43
10
200
s 90, anode down
Convection
SFa7.5-2
SFa9-2
3
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
205
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 103 W/2
69182
100
23
DC
4.44
2550
270 MIN
150000
0.25 x 0.25
30
90
82
43
10
300
s 90, anode down
Convection
SFa7.5-2
SFa9-2
1
56
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 200 W/2 L1
69198
200
61
DC or AC
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
400
s 45, anode down
Convection
SFc10-4
SFc10-4
3
58,59,60
HBO R 103 W/45
69311
100
23
DC
4.3
81.50
300
p 15
Convection
Pin
Pin
2
34,57
HBO®MERCURY SHORT ARC
HBO 200 W/2 L2
69222
200
53
DC or AC
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
400
s 45, anode down
Convection
SFc10-4
SFc10-4
3
58,59,60
12 3
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
206
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 200 W/2 TM L1
69221
200
47
DC or AC
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
400
s 45, anode down
Convection
8-32 UNC-3A
8-32 UNC-3A
1
61
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 200 W/4
69224
200
61
AC
3.6
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
200
s 45, anode down
Convection
SFc10-4
SFc10-4
1
62
HBO 200 W/2 TM L2
69223
200
47
DC or AC
9500
1000
40000
0.6 x 2.2
47.5
128
102
40
17
200
s 45, anode down
Convection
8-32 UNC-3A
8-32 UNC-3A
1
61
HBO®MERCURY SHORT ARC
HBO 200 W/DC
69225
200
57
DC
3.5
10000
1100
40000
0.75 x 2.3
50
128
102
40
17
1000
s 15, anode down
Convection
SFc10-4
SFc10-4
1
1
HBO 201 W/HS-D2
69168
200
25
DC
8
150
127
20
1000
Vertical, anode up
Convection
SFcX32-22
SFcX12-4/15
1
28,63
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Lumens (lm)
Luminous Intensity (cd)
Average Luminance (cd/cm2)
Luminous Area – w x h (mm)
Luminous Efficacy (lm/W)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 250 W/HS
69364
250
40
DC
6.25
143
125
62
20
1000
Vertical, anode down
Convection
SFa 13-5/20
Special
3
63
HBO 202 W/4
69316
200
61
AC
3.6
1000
40000
0.6 x 2.2
47.5
128
102
40
17
200
s 45, anode down
Convection
SFc10-4
SFc10-4
2
64
HBO®MERCURY SHORT ARC
123
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
207
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 250 W/BY
69246
250
40
DC
6.5
152
125
62
20
2
1000
Vertical, anode down
Forced Base
SFc13-5/20
SFc13-5/20
1
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 350 W/S
69228
350
68
DC
5.15
4700
127
103
52.5
20
3
600
Vertical, anode down
Convection
SFcY10-4
SFcY10-4
2
67,70
HBO 500 W/A
69205
500
60
DC
8.3
6200
190
161.5
73
29
4.5
800
Vertical, anode down
Convection
SFcY13-5
SFcY13-5
3
70,71,72
HBO 350 W
69226
350
68
DC
5.3
4600
128
102
45
20
2.9
600
Vertical, anode down
Convection
SFcY 10-4
SFcY 10-4
2
67,68,69,70
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 450 W/GS
69343
450
50
DC
9
150
105
53
22
2.2
600
Vertical, anode down
Convection
SFc 13-5/15
SFc 13-5/15
1
71
12 3
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
208
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 500 W/B
69206
500
48
DC
10.3
5800
180
151.5
78.5
29
3
800
Vertical, anode down
Convection
SFcX13-5/20
SFcY 13-15/20
1
70,71,73,74
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 1000 W/G
69208
750
47
DC
16
8300
197
169.5
85
28
3
600
Vertical, anode down
Forced Base
SFcX14-6/25
SFcX15-4/20
3
67,76
HBO 1002 W/CEL
69177
750
47
DC
16
8300
175
157
78.5
28
3
2500
Vertical, anode down
Convection
SFc15-6/20
SXFc15-6/20
5
76
HBO 1000 W/CEL
69175
750
47
DC
16
8300
175
157
78.5
28
3
2500
Vertical, anode down
Convection
SxFc15-6/20
SFc15-6/20
2
75,76,77
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 1000 W/NEL
69176
750
47
DC
16
8300
190
168
84.5
28
3
2500
Vertical, anode down
Convection
SFa15-5/16
SFaX14-5/21
4
71,76,78,79,80
12345
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
209
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 1002 W/NEL
69273
750
47
DC
16
8300
190
168
78.5
28
3
2500
Vertical, anode down
Convection
SFaX14-5/21
SFc15-6/25
1
77,81
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 1003 W/PI
69195
750
26
DC
27.1
197
169.5
85
29
3
850
Vertical, anode down
Forced Base
SFcX14-6/25
SFc15-6/25
3
76,83,84
HBO 1000 W/D
69200
1000
38
DC
26.5
10800
240
208
89.5
40
3
1000
Vertical, anode down
Forced Base
SFc15-6/25
SFc15-6/25
4
HBO 1002 W/NIL
69347
750
25
DC
27.1
187
168
78.5
29
3
1500
Vertical, anode down
Forced Base
SFaX14-5/21
SFc15-6/25
2
77,82
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 1003 W/PIL
69180
750
26
DC
25.8
195
169.5
85
29
3
1500
Vertical, anode down
Forced Base
SFcX14-6/25
SFc15-6/25
3
76,83,85
12 34
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
210
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 1500 W/CI
69185
1500
23
DC
65.2
262
242
122
52
4
850
Vertical, anode down
Forced Base
SFa27-10/35
SFa27-20/23
1
86,87,88
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 1500 W/CIL
69179
1500
23
DC
65.2
262
242
122
52
4
1500
Vertical, anode down
Forced Base
SFa27-10/35
SFa27-20/23
1
86,88
HBO 1500 W/PIL
69181
1500
23
DC
65.2
273
242
118
46
4
1500
Vertical, anode down
Forced Base
SFc30-6/25
SFc27-10/35
2
66,91,92
HBO 1500 W/CIEL
69171
1500
23
DC
65.2
262
242
122
52
4
2250
Vertical, anode down
Forced Base
SFa27-20/22
SFa27-20/23
1
87,88,89
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 1500 W/PI
69319
1500
23
DC
65.2
267
240
118
47
4
850
Vertical, anode down
Forced Base
SFc30-6/25
SFc27-10/35
2
66,90
12
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
211
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 2000 W/NIL
69303
1750
26
DC
67
241
221
112.25
52
4.5
1500
Vertical, anode up
Forced Base
SFc27-12/35
SFc27-7/35
1
88,92
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 2001 W/NIL
69292
1750
26
DC
67
251
231
112
50
4.5
1500
Vertical, anode down
Forced Base
SFc27-10/35
SFaX27-7/35
2
88,92
HBO 2001 W/CIEL
69166
2000
26
DC
77
329
309
148.75
62
4
2250
Vertical, anode up
Forced Base
SF33.5/50 with cable
connection (M8)
SFa33.5-10/50 with
cable connection (M6)
4
89,93,94
HBO 2001 W/NIEL
69306
1750
26
DC
67
251
231
112.5
52
4.5
2250
Vertical, anode down
Forced Base
SFc27-10/35
SFc27-7/35
2
88,92
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 2002 W/NIL
69287
1750
24
DC
67
254
234
107.5
52
4.5
1500
Vertical, anode up
Forced Base
SFc27-7/35
SFc27-10x1.25/35
3
86,92
12 34
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
212
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
213
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 2001 W/CIL
69189
2000
26
DC
77
329
307
149
62
4.5
1500
Vertical, anode up
Forced Base
SF33.5/50
SFa33.5-10//50
1
86,92,93,95
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 2011 W/NIL
69288
2000
24
DC
80
256
236
107.75
52
4.5
1500
Vertical, anode up
Forced Base
SFc27-7/35
SFc27-12x1.5/35
3
86,92
HBO 2002 W/MA
69199
2000
37
DC
54
292
272
138.5
62
3
1000
Vertical, anode down
Forced Base
SF27/35
SFa27-10/35
2
28,86,88,92,96
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 2500 W/PIL
69172
2500
28
DC
90
350
315
149
62
6.7
1500
Vertical, anode up
Forced Base
SFc30-6/50
SFc30-6.3/50
4
28,89,92,97
1234
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
214
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
HBO 2501 W/NIL
69289
2500
23
DC
110
367
327
157.75
70
4.5
1500
Vertical, anode down
Forced Base
SFc33.5-8/50
SFc33.5-14/5
1
28,86
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 2700 W/CIL
69344
2700
24
DC
110
334
309
148.75
62
1500
Vertical, anode up
Forced Base
SFa33.5/50
SFa33.5-14.59
3
71,86,99
HBO 2510 W/NIL
69299
2500
23
DC
109
367
327
157.5
70
4.5
1500
Vertical, anode up
Forced Base
SFc33.5-8/50
SFc33.5-14/50
2
28,92,98
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 3500 W/PI
69174
3400
23
DC
148
340
315
154
77
4.5
850
Vertical, anode up
Forced Base
SFaX40-6/50
SFc32.5-6.7/50
4
28,89,92,100
123 4
HBO 3500 W/PIL
69169
3400
23
DC
148
360
315
154
77
4.5
1500
Vertical, anode up
Forced Base
SFaX40-6/50
SFc32.5-6.7/50
1
28,65,89,92
Ordering Abbreviation
Product Number
Watts (W)
Volts (V)
Type of Current
Current (A)
Radiant Intensity 350..450 nm (mW/sr)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Electrode Gap -- cold (mm)
Avg Rated Life (hrs)
Operating Position
Cooling
Base Anode
Base Cathode
Fig No
Symbols & Footnotes
HBO 3501 W/PIL
69165
3400
23
DC
148
360
315
154
77
4.5
1500
Vertical, anode up
Forced Base
SFc32.5-6.7/50
SFaX40-6/50 with cable
connection (M10)
1
65,85,91,97,99,101,10
2,103
HBO 5500 W/PI
69164
5000
25
DC
200
355
154
85
5.5
850
Vertical, anode up
Forced Base
SFcX 42.5-6/50
SFa 37.5-9/50
2
9,30,83,89,104
HBO 3501 W/PI
69127
3400
23
DC
148
360
315
154
77
4.5
850
Vertical, anode up
Forced Base
SFaX40-6/50
SFc32.5-6.7/50
1
28,89,92
HBO®MERCURY SHORT ARC FOR MICROLITHOGRAPHY
HBO 4500 W/CIL
69162
4500
30
DC
148
360
315
154
77
1500
Vertical, anode up
Forced Base
SFAX40-6/50
SFC32.5-6.7/50
1
65,66
12
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
215
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
Na 10 FL
69284
Sodium
9
16
0.57
AC
Vertical, base down
Pico 9
3
111,112
XERADEX 20
69338
20
245
120
75
40
1500
Any
1
105,106,107,108
Ordering Abbreviation
Product Number
Elements
Watts (W)
Volts (V)
Current (A)
Type of Current
Operating Position
Base
Fig No
Symbols & Footnotes
Ordering Abbreviation
Product Number
Watts (W)
Length l1max (mm)
Length l2max (mm)
Distance a (mm)
Diameter d (mm)
Avg Rated Life (hrs)
Operating Position
Fig No
Symbols & Footnotes
XERADEX 20/SY45/45
69349
20
300
125
45
40
1500
Any
2
105,106,107,110
XERADEX 20/HV
69352
20
245
120
75
40
1500
Any
1
105,106,107,109
EXCIMER AND SPECTRAL LAMPS
1
2 3
SPECTRAL
EXCIMER - XERADEX
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
216
P
H
O
T
O
O
P
T
I
C
D
I
S
C
H
A
R
G
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
217
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
LAMP BASES
BA15d
IEC 7004-11
DIN 49721
DL
Bayonet
BA15s
IEC 7004-11A
DIN 49720
SC
Bayonet
BA20d
IEC 7004-12
DIN 49730
E10
IEC 7004-22
DIN 49610
miniature
Edison
E14
IEC 7004-23
DIN 49615
small
Edison
E27/E26
IEC 7004-21
DIN 49620
E26-NA
E27-EURO
E40/E39
IEC 7004-21
DIN 49625
E39-NA
E40-EURO
FaX1.5-3x1 G4
IEC 7004-72
DIN 49757
2-pin
GX5.3
IEC 7004-61
DIN 49640
2-pin
G5.3-4.8
2-pin GY5.3
2-pin G6.35-15
G6.35-20
G6.35-25
IEC 7004-59
2-pin
GX6.35-25
IEC 7004-59
2-pin
GY6.35-15
IEC 7004-59
2-pin
GZ6.35
IEC 7004-59 A
DIN 49754
2-pin
GZX9.5
GZZ9.5
IEC 7004-70 B
DIN 49756
2-pin
pre-focus
G9.5
IEC 7004-70
medium
2-pin
GX9.5
DIN 49638
IEC 7004-70 A
2-pin
pre-focus
GY9.5
GZ9.5
DIN 49756
IEC 7004-70 B
2-pin
pre-focus
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
218
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
LAMP BASES
GX16d
2-pin GY16
DIN 49758
IEC 7004-45
2-pin
GY17q
DIN 49758
IEC 7004-74
4-pin
GY17t
DIN 49665
IEC 7004-45
4-pin
G22
IEC 7004-75
medium
Bipost
GY22
2-pin
P40s
DIN 49728
IEC 7004-43
medium
pre-focus
Pico9
DIN 41539 PG22-6.35
DIN 49751
IEC 7004-48
P28s
DIN 49728
IEC 7004-42
MOGUL
pre-focus
G38
IEC 7004-76
MOGUL
Bipost
GX38q K24s
Length of cable
250 mm
Hole of cable lug
ø 8.4 mm
DIN 49748
PK30d R7s
RX7s
DIN 49750
IEC 7004-92
K30 s
Length of cable
275 mm
Hole of cable lug
dia 8.4 mm
DIN 49748
K39 d
with flexible Siaf cable
Length of cable 300 mm.
Hole of cable lug dia. 8.4 mm
K59 d
with flexible Siaf cable
Length of cable 350 mm.
Hole of cable lug dia. 8.4 mm
DIN 49732
.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
219
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
LAMP BASES
SK27-50 SFa15-10
SFa16-8
SFa16-10
SFa20-8
SFa20-10
SFa25-10
SFa27-8
SFa27-10
SFa27-11
SFa27-12
SFa27-14
SFa28-18
SFa21-12
DIN 49759 SFaX27-10
SFaX27-9.5
SFaX27-12
SFaX27-13
SFaX27-14
SFaX30-9.5
SFaX30-16
SFcX27-8
(5/16-18UNC-2 A) SFc25-14 (M 14x1.5)
SFc27-14 (M 14x1.5)
SFcX12-4
(with M4 thread and
centering collar)
SFcX 13-4
SFcX 15-4 (with US inch
thread 8-32 UNC-3A and
centering collar)
SX15s X515
DIN 49613
SFc10-4 M4-thread
SFc6-3 M3-thread
SFc12-4 M4-thread
SFc13-4 M4-thread
SFa5-2
SFa6-2
SFa7.5-2
SFa8-2
SFa9-2
SFa12-11
SFa21-5
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
220
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
OPERATING POSITIONS
Schematic diagrams
permitted
not permitted
GENERAL INFORMATION
In North America, OSRAM brand Photo-Optic lighting products are sold by OSRAM SYLVANIA AND OSRAM SYLVANIA LTD. Sales are
subject to standard terms and conditions of sale prevailing as of the date of purchase.
Operational data and dimensions are nominal values. OSRAM reserves the right to make technical modifications without notice. All
supplies are subject to availability.
® = Registered trademarks of OSRAM GmbH
Lamps are designated in accordance with ANSI standard C78.370-1982 (As amended).
When disposing of spent lamps, always consult federal, state, local and/or provincial hazardous waste disposal rules and regulations to
ensure proper disposal.
Use of improper, unapproved or unsuitable ballasts will negatively impact the performance of Photo-Optic lamps and could void the lamp
warranty. A list of power supply manufacturers is available upon request.
Discharge lamps in the HMD®, HMI®, HMP®, HTI®, HSR®, HSD®, HBO®, OSRAM STUDIOLINE® and VIP®types and the spectral lamps
contain small quantities of harmful substances (such as mercury).
For more complete product information visit www.sylvania.com 221
SYMBOLS & FOOTNOTES FOR PHOTO-OPTIC HALOGEN LAMPS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Footnote Description
1Base - filament connections: Pins 1 and 4.
2Lamp has monoplane filament.
3Lamp has internal proximity reflector.
4Lumens refers to screen lumens.
5Lamp also available as a 240V model (Product Number 54977).
6Product number 54100 is the replacement for product number 54048.
7Lamp service life 75hr life is defined at 76V with a duty cycle of 45 min. ON / 15 min. OFF.
8Lamp suited for video camera heads; 500hr life @ 1.8V/ 45 min. ON / 15 min. OFF.
9Lamp has round-core double filament.
10 h (Operating Position) = Vertical, base up
11 Lamp has a flat core filament with filament area perpendicular to the lamp axis.
12 Lamp also available in 240 V model.
13 Length l1 = Contact to contact.
14 Length l = Contact to contact.
15 Lamp also available as 115V model (Product Number 54636).
16 Lamp interchangeable with HX 600
17 Lamp has a biplane filament.
18 Lamp interchangeable with HX 602
19 High-performance HPL halogen lamps are manufactured under license from ETC,Inc.
20 Do not tilt perpendicular to the filament.
21 NSP=Narrow Spot
22 WFL=Wide Flood
23 VNSP=Very Narrow Spot.
24 MFL=Medium Flood
25 For use where seal temperature does not exceed 650F.
26 Life at rated voltage and at 650F maximum seal temperature.
27 Clean room ready packaging.
28 A suitable protective shield, screening technique, or both must be used to protect people and surroundings from the possibility of a lamp
shattering and from possible ultraviolet radiation.
29 High temperature base. Retards seal deterioration where seal temperature exceeds 650F.
30 Usually limited to intermittent burning.
31 Average service life of lamp if operated with 400W is 100 hrs.
32 Snap-on connector, female / male contact.
33 Connector = Female, round, with 4mm pin.
34 Lamp also available with male connectors (Product Number 58722)
35 Female contact is according to DIN 46247.
36 Lamp also available with female connectors (Product Number 58697)
37 Male contacts according to DIN 46248.
38 Lamp also available with female connectors (Product Number 58721)
39 Lamp also available with female connectors (Product Number 58709)
40 This lamp type is twice the life of the ANSI standard version.
41 WARNING: Lamp only for use where seal temperature does not exceed 650 degrees F (343 degrees C). Minimum bulb wall temperature 480
degrees F (249 degrees C).
42 Lamp also available with male contact according to DIN 46248. 64361/HLX Z (Product Number 58717)
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com
222
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
SYMBOLS & FOOTNOTES FOR PHOTO-OPTIC HALOGEN LAMPS
Footnote Description
43 This lamp type is twice the life of the standard version.
44 Max. Beam Candlepower (MBCP) : 175 kcd.
45 Lamp has snap-on male contact to DIN 46248.
SYMBOLS & FOOTNOTES FOR PHOTO-OPTIC DISCHARGE LAMPS
Symbol Description
New item introduced within the past year.
Item will be discontinued when inventory is depleted.
Footnote Description
1Type of current: square-wave AC.
2p (Operating Position) = Horizontal
3OSRAM socket #46721, cable length 22" for use with the following OSRAM lamps: HTI 250W/SE (product number 54091), HTI 400W/SE
(product number 54084), HTI 600W/SE (product number 54087), and HMI 250W/SE (product number 54062).*
4Type of current: sine-wave (sinusoidal) AC.
5In horizontal operation position it is recommended that the "lead connection" wire be in the top position with filler tip facing down.
6Optimized lamp seal technology to withstand interior base temperatures of up to 450 degrees C.
7GS=Gap Shortened
8S=Short
9Lamp bases need to be forced cooled.
10 Necessary input voltage: 380 volt.
11 Permitted wattage range: 400W to 700W.
12 Lamp filler tip needs to point upwards during operation.
13 Permitted wattage range: 300W to 600W.
14 Lamp arc needs to be in horizontal operating position.
15 Current bar needs to be positioned underneath the discharge arc during operation.
16 Lampholder for FaX 1.5 base = HMI Socket 46721 (Product Number 69302).
17 All HTI® lamps are hot restrikeable with the exception of HTI 150, HTI 152, HTI 405 W/SE, and 705 W/SE.
18 SE=Single Ended
19 WARNING: Lamp has a special GY22 base. Ignition voltage must be applied only to the thin pin.
20 WARNING: The contact pins on the base are connected internally. The electrode farthest from the base must be connected via cable.
21 DX=Type of Double Ended
22 Lamp is also available with connecting cable and plug-in contact. HTI 250W/32 C (Product Number 54089).
23 When operated on electronic control gear (ECG) service life extended to 3000h.
24 Lamp HSD 250/78 also available with 7800K color temperature and average rated life at 3000 hr. Product Number 54118.
25 All VIP® lamps are for AC operation on electronic power supplies and are hot restrikeable. All VIP® lamps need forced cooling.
26 Lamp has a elliptical reflector.
27 Lamp also available in ozone-free version XBO 75 W/2 OFR (Product Number 69232)
28 This lamp has positive pressure even when cold. Please read safety/warning instructions before using this lamp.
29 Distance a is from end of base to the respective electrode tip (cold) - see lamp drawing.
30 With vertical operating position: anode(+) on top.
31 OFR=Ozone Free
32 Lamp also available with connecting cable and plug-in contact. XBO R 100W/45 C OFR (Product Number 69191).
33 Lamp current not to exceed 7.2A.
34 The focus lies 45mm in front of the mounting rim (working distance).
35 C=Cable
For more complete product information visit www.sylvania.com 223
SYMBOLS & FOOTNOTES FOR PHOTO-OPTIC DISCHARGE LAMPS
Footnote Description
36 The connecting cables do not have a plug-in connector.
37 Lamp also available in ozone-free version XBO 150 W/1 OFR (Product Number 69235)
38 Lamp also available in Suprasil quartz glass version: XBO 150 W/4 (Product Number 69238).
39 Lamp uses Suprasil quartz glass.
40 Magnetic arc stabilization required.
41 Lamp is suitable for Crosfield color scanner (CR = Crosfield).
42 Lamp also available with connecting cable and plug-in contact. XBO 180W/45 C OFR (Product Number 69183).
43 Lamp focus is 60mm in front of reflector rim.
44 Lamp also available in ozone-free version XBO 450 W OFR (Product Number 69245)
45 Lamp also available in Suprasil quartz glass version XBO 450 W/4 (Product Number 69244)
46 Photometric data is measured in vertical operating position at rated wattage.
47 CA=Cable on anode base
48 TP=Threaded Pin
49 Lamp also available as XBO 2001 W/HTP OFR (Product Number 69310).
50 SHSC=Super short
51 Lamp has same dimensions as XBO 1600 W/HSC OFR (Product Number 69268).
52 Lamp also available as XBO 4200 W/GS with 60mm bulb diameter and 500 hrs life.
53 H=Suitable for horizontal operation
54 Magnetic arc stabilization: necessary for horizontal operation
55 Lamp XBO 10000 W/HS OFR also available with current control range 160-299 amps. Product Number 69342.
56 Lamp optimized for fluorescence microscopy.
57 Lamp also available with AMP plug contact. HBO R 103/45 C (Product Number 69311).
58 For DC operation both Product Numbers 69198 & 69222 can be used (47...65Volts / 3.1...4.2Amps). For AC operation Product Number
69198 (L1 version 57 65 Volt / 3.6 Amps) or Product Number 69222 (L2 version 49 57 Volt / 4.2 Amps) can be used.
59 Lamp also available with threaded pin 8-32 UNC-3A: HBO 200 W/2TM (Product Number 69223).
60 Technical data if operated on AC current: Volts=65, Lumens=10,000 lm, Luminous Efficacy=50 lm/W.
61 For DC operation both Product Numbers 69221 & 69223 can be used (47...65 Volts / 3.1...4.2Amps). For AC operation Product Number
69221 (L1 version 57 65 Volt / 3.6 Amps) or Product Number 69223 (L2 version 49 57 Volt / 4.2 Amps) can be used.
62 Lamp also available with increased radiation in the wavelength range below 450nm for UV-curing. HBO 202W/4 (Product Number 69316).
63 2000hr warranty against non-passive lamp failure.
64 Lamp same as HBO 200 W/4 (Product Number 69224 but with increased radiation in the wavelength range below 450nm for UV-curing.
65 Lamp also available with 850 hrs (HBO 3500 W/PI, Product Number 69174)
66 Anode Base=Cooling fins with cable connection (M 8).
67 Anode and Cathode Base with UNC-3A thread.
68 Lamps suitable for pulse operation between 250W and 500W. Maximum permissible average power is 350W (also for constant power opera-
tion).
69 HBO 350W (Product Number 69226) replaces HBO 350 W/G (Product Number 69227).
70 Lamp service life is defined with a switch-on/switch off duty cycle of 12hours ON / 30 minutes OFF.
71 Maximum permitted base temperature: 200 degrees C (392 degrees F).
72 Lamp base(s) with M 5x0.9 thread.
73 Cathode base with M 5x 0.9 thread
74 Lamp anode base (hexagon) with thread M5x0.9
75 Anode Base=Hexagon base with M 6 thread.
76 Lamps suitable for pulse operation between 700W and 1000W. Maximum permissible average power is 750W (also for constant power oper-
ation).
77 Cathode Base=Sleeve base with M 6 thread.
78 Cathode base with cable connection (M 5)
79 Cathode Base with cooling fins.
80 Anode sleeve base without thread.
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com
224
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
SYMBOLS & FOOTNOTES FOR PHOTO-OPTIC DISCHARGE LAMPS
Footnote Description
81 Anode Base=Sleeve base with cable connection (M 5)
82 Anode Base=Sleeve base with cable connection (M 6).
83 Lamp has cooling fins on anode base.
84 Lamp also available as Longlife version HBO 1003 W/PIL (Product Number 69180) with 1500hr life.
85 Lamp also available as version HBO 1003 W/PI with 850hr life (Product Number 69195)
86 Anode Base with cable connection (M 8).
87 Lamp also available as Longlife version HBO 1500 W/CIL (Product Number 69179) with 1500hr life.
88 Cathode Base with cable connection (M 8).
89 Anode Base with cable connection (M 10).
90 Lamp also available as Longlife version HBO 1500 W/PIL (Product Number 69181) with 1500hr life.
91 Lamp also available with 850 hr HBO 1500 W/PI (Product Number 69319)
92 Lamp should not be ignited more than ten times over lifetime.
93 Lamp also available as version HBO 2001 W/CI with 850hr life (Product number 69219)
94 Lamp also available as version HBO 2001 W/CIL with 1500hr life (product number 69189)
95 Cathode Base with cable connection (M 6).
96 The average rated life of this lamp depends on the operating mode (initial power setting).
97 Lamp also available as version HBO 2500 W/PI with 850hr life (Product Number 69178)
98 Anode base with cable: length 340mm; connector 8/25.
99 Distance a = Distance (cold) of either anode base to anode tip or cathode base to cathode tip depending on lamp type.
100 Lamp also available as Longlife version HBO 3500 W/PIL with 1500hr life (Product Number 69169).
101 Average service life of lamp if operated with 400W is 100 hrs.
102 Also available with 850h, HBO 3501 W/PI: NAED 69127.
103 SHP - series (Super High Performance Technology).
104 Lamp life may vary depending on duty cycle and application.
105 The XERADEX®20 lamp must be operated with DBD 20/110-240/ECG-XERADEX power supply (Product Number 69128 or 69129).
106 XERADEX lamps are only to be operated in appropriate equipment. Read and understand the Product Safety Warnings before using this
product. XERADEX lamps generate a strong 172 nm (VUV) radiation. This short-wave radiation will convert atmospheric oxygen (O2) sur-
rounding the lamp into ozone (O3). Ozone gas is toxic when inhaled in high concentrations over long periods of time. Ozone levels can be
measured and monitored with commercial measuring equipment. Always keep ozone levels below the applicable TLV (threshold limit value).
107 XERADEX lamp life is rated in terms of 70% of initial UVC output on a continuous burn cycle.
108 Base is KF50 flange fitting; lamp is designed for use in vacuum environments at pressures above 300 mbar.
109 Base is KF50 flange fitting; lamp is designed for use in high vacuum environments at pressures above 200 mbar and below 10^-3 mbar.
110 Base is KF40 flange fitting; lamp is designed for use in high vacuum environments at pressures above 30 mbar and below 10^-3 mbar.
111 For Na 10 FL (product number 69284) use adapter no. 454/s using Pico 9 bases with P28 sockets.
112 Safety: Because the danger from glare, UV radiation and overpressure during operation, spectral lamps may only be operated in sealed hous-
ings specially designed for the purpose. Suitable filters must be fitted to ensure that UV radiation is reduced to permissible levels.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
225
TUNGSTEN HALOGEN & INCANDESCENT PHOTO-OPTIC LAMPS
The following information pertains to all Photo-Optic Tungsten-Halogen and Incandescent lamps including Infrared Heat Lamps, Current-Controlled Airfield Lamps,
PAR and other Reflector Lamps.
WARNING:
In accordance with ANSI/IESNA Standard RP-27, Photo-Optic incandescent & tungsten halogen lamps are Risk Group 2 products.
Read and understand this warning before using this bulb!
THIS LAMP EMITS ULTRAVIOLET AND INFRARED RADIATION. ALWAYS WEAR SUITABLE EYE PROTECTION WHEN WORKING NEAR THIS LAMP. THIS LAMP
OPERATES AT HIGH PRESSURE AND AT HIGH TEMPERATURE AND MAY SHATTER UNEXPECTEDLY. THIS LAMP MUST BE USED IN A FIXTURE THAT HAS A SUIT-
ABLE PROTECTIVE SHIELD AND/OR SCREEN TO PROTECT PEOPLE AND SURROUNDINGS AGAINST THE RISK OF PERSONAL INJURY AND/OR PROPERTY DAMAGE
FROM LAMP SHATTERING AND EXPOSURE TO INFRARED OR ULTRAVIOLET RADIATION.
ALL OF THE FOLLOWING PROCEDURES MUST BE FOLLOWED FOR SAFETY AND TO OBTAIN SATISFACTORY LAMP PERFORMANCE.
GENERAL SAFETY AND INSTALLATION TIPS:
1. This lamp generates UV (ultraviolet) and/or IR (infrared) radiation. Prolonged exposure to this lamp may cause skin and eye irritation from the radiation when
operated at or above rated voltage.
Please note that lamp with reference number 64614 has enhanced UV output as a result of its reflector coating.
2. To avoid risk of serious eye injury from the intense light, do not stare at operating lamp.
3. Because this lamp radiates considerable heat, do not use in close proximity to people, combustible materials, or substances adversely affected by heat or drying.
4. To avoid shattering of glass parts and/or lens/reflector, keep water, other liquids and metal objects from contacting hot glass surfaces. Protect the entire lamp
from moisture (rain, snow, etc.) to avoid cracking or breaking.
5. Protect the lamp from contamination, abrasion and scratches. Do not use if lamp is scratched, cracked or damaged in any way.
6. For safe and proper lamp operation, operate at rated voltage and wattage. Operation above rated voltage increases UV output and internal pressure, thus increas-
ing the risk of rupture.
7. This lamp (for reflectorized lamps, this applies to inner lamp capsule) operates at high internal pressure and at high surface temperature and may unexpectedly
shatter resulting in hot, flying fragments of glass or metal. Although this lamp was carefully constructed, tested and inspected before packing and shipping, under
certain conditions beyond the manufacturer's control, the glass parts could crack or break.
8. For PAR and other reflectorized lamps: Even though this lamp may continue to operate after the reflector and/or lens is broken or damaged, it should be replaced
as soon as possible since the pressure-filled inner lamp capsule could unexpectedly shatter if scratched or otherwise damaged, creating a risk of personal injury
or property damage.
LAMP MOUNTING AND OPERATION:
1. Use only in equipment/fixture specifying this lamp type, including voltage and wattage. Use in circuits, which do not exceed rated voltage and in sockets and
equipment designed for its use.
2. Do not touch or handle the quartz glass with bare fingers. Contaminants can burn in at high operating temperatures and cause glass to recrystalize. This makes
the glass opaque and milky; it increasingly loses its strength, and the risk of bursting increases. If lamp is touched, clean with denatured alcohol and wipe dry
with a soft, clean lint-free cloth before operating.
3. Make sure lamp is properly installed into socket to obtain good electrical contact and to avoid damaging lamp and/or socket. A heat resistant connector should be
used to make electrical contact to the lamp base for safety and to obtain rated lamp life. To avoid damage to lamps with bipin bases, do not twist. Pull old lamp
straight out and push new lamp straight in. For safe and proper operation of lamps with lead wires, please ensure that the lamp is securely supported and the
lead-wires are securely connected to the electrical supply.
For PAR 36, 46, 56, 64 lamps: To avoid breaking, the lamp must be supported by its rim.
4. Operating temperatures deteriorate lamp sockets. Socket condition may affect lamp life. Replace socket if deterioration of socket or lamp base contacts is
observed.
5. Do not move, bump or bounce equipment/fixture during operation because mechanical shock can cause shattering and failure of the lamp.
6. For PAR 36, 46, 56 and 64 lamps: Lamp should be operated with a protective shield (especially in public places -- churches, auditoriums, etc) to prevent the risk
of personal injury or property damage from flying lamp fragments in the event of the lamp cracking or breaking.
7. To avoid risk of burns or electrical shock, do not remove or insert lamp when power is on, allow lamp to cool to room temperature before removing or storing.
8. Replace all equipment/fixture covers and shields after servicing to prevent personal injury or property damage.
9. All Photo-Optic lamps have a range of permissible operating positions. Please see relevant operating position information in our literature or on-line catalog and
only operate lamps at the operating positions specified. The basic rule for all single-ended Photo-Optic halogen and incandescent lamps is that the lamp may only
be tilted/inclined perpendicular to the plane through both filament lead-wires (see illustrations and list of affected filament designs below).
10. Keep lamp seal temperature below 350°C (660°F) and the lamp wall temperature between 250°C (480°F) and 900°C (1650°F). When used in equipment designed
to provide cooling to operating lamp, do not obstruct equipment cooling system.
11. Filaments for high luminance applications are designed in such a way that the incandescent elements do not block each other in the direction of projection. The
positioning of single filament coils in one plane is called a monoplane filament. Biplane filaments have the incandescent elements staggered forward and back-
ward in two parallel planes while maintaining adequate spacing to prevent arc-over.
12. Note: Photometric values of a frosted lamp will vary from the published values of the same non-frosted type.
Affected Filament Designs:
C-2V, C-6, C-6F, C-13, C-13D, CC-2V, CC-6, CC-13, CC-13D, 2C-8, 2CC-8
WARNING
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
Not Permitted Not PermittedPermittedNot Permitted
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
226
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
TUNGSTEN HALOGEN & INCANDESCENT PHOTO-OPTIC LAMPS (continued)
LAMP DIMMING:
1. Incandescent lamps (non-halogen): Incandescent lamps perform according to fixed relationships between luminous flux, luminous efficacy, color temperature,
electrical voltage, electrical current and electrical power consumption. In general, a 5% increase in applied lamp voltage results in half the lamp life, and converse-
ly a 5% reduction of lamp voltage results in twice the lamp life.
2. Tungsten-Halogen Lamps: In standard incandescent lamp operation, there is an inverse relationship of lamp life vs. supply voltage; i.e., the lower the voltage, the
longer the life. In some tungsten halogen lamps, however, this holds true only when operated within 5 to 10% of the rated voltage. Further dimming, beyond the
10%, may affect the halogen chemistry in the lamp and may cause filament corrosion. There are also tungsten halogen lamps that only achieve nominal lamp
lives regardless of the level of dimming that is used. Unlike standard incandescent lamps, the relationships in halogen lamps are not clear-cut because of the
halogen chemical cycle. For the vaporized tungsten to be removed from the inner bulb wall, a minimum bulb wall temperature is necessary. This temperature is
directly related to the power input to the lamp such that a reduction in power effects a reduction in the bulb wall temperature. Special design techniques have
been incorporated in modern halogen lamps to prevent blackening regardless of the level of dimming. Consideration must be given to lamp dimming in applica-
tions that require maximum constancy of color temperature (photographic and video recording, for example), since the color temperature changes with the fila-
ment temperature.
CURRENT-CONTROLLED HALOGEN LAMPS:
Some lamp types are designed for constant current operation, primarily for airfield applications. They are usually operated in series with an isolation transformer tap
connected to each lamp to ensure that all lamps have the same brightness. Constant current-operated lamps differ in performance from the published values of con-
stant applied voltage lamps. Direct series connection of non-constant current designed lamps is not recommended.
INFRARED HEAT LAMPS:
These lamps are designed for use in applications specifically requiring an infrared radiation source. Infrared radiation from these lamps causes surfaces to be heated.
These lamps operate at high temperatures. Allow sufficient cooling time before handling. A listing of Kelvin temperatures, method for electrical connection, and oper-
ating positions with appropriate cooling recommendations for tungsten halogen special heat lamps can be found in the OSRAM literature or in the on-line catalog.
CAUTION: The infrared reflector lamp, HLX 64635 is specially designed to produce high temperatures at its focal point (approximately 1300°C / 2372°F) for soldering,
welding and heating applications.
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
METAL HALIDE PHOTO-OPTIC LAMPS [HMI®, HMD®, HMP®, HSD®, HSR®, HTI®]
WARNING:
In accordance with ANSI/IESNA Standard RP-27, Photo-Optic metal halide lamps are a Risk Group 3 product.
Read and understand this warning before using this lamp!
THIS LAMP EMITS ULTRAVIOLET AND INFRARED RADIATION. ALWAYS WEAR SUITABLE EYE PROTECTION WHEN WORKING NEAR THIS LAMP. THIS LAMP
OPERATES AT HIGH PRESSURE AND AT HIGH TEMPERATURE AND MAY SHATTER UNEXPECTEDLY. THIS LAMP MUST BE USED IN A FIXTURE THAT HAS A SUIT-
ABLE PROTECTIVE SHIELD AND/OR SCREEN TO PROTECT PEOPLE AND SURROUNDINGS AGAINST THE RISK OF PERSONAL INJURY AND/OR PROPERTY DAMAGE
FROM LAMP SHATTERING AND EXPOSURE TO INFRARED OR ULTRAVIOLET RADIATION.
RUPTURE & RADIATION (UV-IR-VISIBLE) HAZARD:
1. All Photo-Optic metal halide lamps operate at high internal pressures (upwards of 500psi or 35bar possible) and may unexpectedly rupture resulting in the dis-
charge of hot fragments (approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of mercury/mercury vapor. In the event of such a
rupture, there is a risk of personal injury, burns and fire.
2. All Photo-Optic metal halide lamps generate ultraviolet (UV), infrared (IR) and visible radiation during operation. This radiation can cause permanent damage to the
eyes (including blindness) and serious injury to the skin (including burns and blistering). To avoid eye damage, other personal injury and/or property damage, the
lamp MUST be operated in a suitable fixture.
3. A suitable fixture is one that will prevent the arc from being viewed directly while operating, and in the event of a lamp rupture, will prevent hot (up to 800°C /
1472°F), flying fragments of quartz and/or metal from escaping into the area.
4. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life) or when the lamp
shows signs of blackening.
5. The discharge vessel of Photo-Optic metal halide lamps is constructed of quartz glass that is filled with a quantity of mercury, elemental metals and/or rare earth
elements. These lamps are not at positive pressure when cold (not operating, at room temperature).
GENERAL SAFETY & INSTALLATION TIPS
BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):
1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor. The area should then
be thoroughly ventilated for a minimum of 30 minutes or until the mercury vapor in the area is below the ACGIH TLV (American Conference of Governmental
Industrial Hygienists Threshold Limit Value). Inhaling vapor or small particles of mercury or its compounds can be harmful to lungs, kidneys and nervous system.
Penetration of the skin or ingestion can also be harmful.
2. To avoid mercury vapor getting into air conditioning systems, mercury vapor-absorbing filters should be used. When the lamp housing has cooled, mercury
residue may be picked up with special mercury adsorptive agents or a mercury vacuum cleaner (available from laboratory safety equipment suppliers) and
disposed of in accordance with local, state and federal regulations. There should be no direct skin contact with and/or inhalation of mercury residues that may
be residing in lamp housing, optics or lamp parts.
If a cold (room temperature) lamp is broken, proceed with clean up and disposal as indicated above (in the bold, italic statement).
WARNING
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
227
METAL HALIDE PHOTO-OPTIC LAMPS [HMI®, HMD®, HMP®, HSD®, HSR®, HTI®](continued)
INSTALLATION:
1. Do not use if lamp is scratched, cracked or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands. Use clean gloves.
4. If the quartz parts are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a clean, soft, lint-free cloth. Do not use cleaning rags
or material that can leave a residue.
5. To prevent skin burns, allow lamp to cool before handling.
6. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion along its
axis.
7. Photo-Optic metal halide lamps should not be subjected to force/stress during installation. Single-ended lamp types use a metal bar, which runs parallel to the
lamp body and provides an electrical path for the lamp current (from the socket end to the opposite end of the lamp). To avoid overheating the lamp current bar,
Photo-Optic metal halide lamp types without outer jackets should not have the lamp current bar positioned above the discharge arc during operation. Single-
ended lamp types with outer jackets may be operated in any position and with any current bar position.
8. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury or property damage.
9. Use only in instruments/equipment specifying this light source.
10. CAUTION - Shorting Hazard: The HTI 2500 W/SE has both base pins connected to the same point inside the lamp socket. A lead wire on the opposite side of the
lamp provides the current connection necessary for operating the lamp.
11. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector.
electrical connections should be free from dirt and corrosion. Socket/connector condition may affect lamp life. Replace socket/connector or lamp if deterioration
(pitting, scorching, corrosion, etc.) is observed.
Please note that certain Photo-Optic, AC metal halide lamps have dedicated pins or connectors for high voltage ignition.
OPERATION:
1. Magnetic current-limiting ballasts (chokes) provide sine-wave current operation for lamps. However, electronic control gear (ECG) allows for square wave cur-rent
operation, often at higher frequencies. Some Photo-Optic metal halide lamps have been designed for, and therefore require, ECG square-wave operation. Please
see OSRAM literature for power requirements for your specific lamp type.
2. Operate with compatible power supply and fixture only.
3. OSRAM Photo-Optic metal halide discharge lamps are designed for either hot re-start (high ignition voltages) or cold start (low ignition voltages only). Please see
OSRAM literature for power requirements for your specific lamp type.
4. To ensure that lamps operate at the correct power during AC operation, connections on the ballast/choke in the power supply should be made to the correct volt-
age taps; i.e., tap voltage should match input line voltage. To avoid wall blackening, overheating or other premature failure modes, OSRAM strongly advises
against operating Photo-Optic metal halide lamps at higher than rated wattage ("boosted operation"). Only OSRAM HMP Photo-Optic metal halide lamps are
offered with a unique power feature allowing for operation at increased wattage of up to 1.5 times their rated wattage, but with reduced service life. For safe lamp
operation and optimum performance, use only those ballasts/power supplies that have been approved by OSRAM. See your OSRAM dealer for a list of approved
equipment.
5. Dimming of Photo-Optic metal halide lamps, like incandescent lamps, causes a drop in luminous output. If a metal halide lamp is dimmed by electrical means, it
will not reach its optimum operating state and, unlike incandescent lamps, will not last longer. When dimmed, the lamp wall temperature falls more rapidly on a
lamp that has no outer jacket. In metal halide lamps without an outer jacket, reduced power operation causes an increase in the color temperature and a reduction
in CRI. Lamps with outer jackets can have either a vacuum or filling gas (often Nitrogen) within. Metal halide lamps with outer jackets tend to maintain their color
properties better under dimmed conditions because the outer jacket provides thermal insulation against internal lamp cooling.
6. Photo-Optic metal halide lamps need 5 to 20 minutes (depending on lamp type and cooling conditions) before they reach their operating temperatures. To ensure
proper ignition on subsequent start-up, lamps should not be switched off during the warm-up period.
7. Average service life of these lamps is determined by the ON/OFF duty cycle. Lamp performance is reduced with increased duty cycle.
OPERATING POSITION:
Photo-Optic metal halide lamps may only be used in the operating positions described in the OSRAM SYLVANIA product catalog. Please note that lamp photomet-
ric values and arc stability can be effected by the operating position.
OZONE GENERATION:
During operation, Photo-Optic metal halide lamps produce a spectrum that ranges from about 150 nm in the ultraviolet region to the infrared region.
If the quartz glass bulb is transparent in the ultraviolet region between 180 and 220 nm, this short-wave radiation will convert a small quantity of atmospheric oxy-
gen (O2) surrounding the lamp into ozone (O3). Moreover, the oxygen molecules will link together with the nitrogen (N2) in the air, creating nitrogen oxides (NOx).
(Some believe that the smell attributed to ozone is in actuality from the nitrogen oxides.)
Ozone gas is toxic when inhaled in high concentrations over long periods of time. Ozone levels can be measured and monitored with commercial measuring
equipment. Always keep ozone levels below the applicable TLV (threshold limit value)
An "ozone smell" (or smell of nitrogen oxide) may be detected shortly after ignition. There are two probable causes for this condition. O3and NOxproduction is
caused by the (short-duration) radiation of the spark gap used for lamp ignition. Or, the cold condition of the quartz glass bulb has slightly shifted its UV-absorp-
tion characteristics thus permitting a small amount of radiation in the very short-wave ultraviolet range to be emitted by the bulb. Typically, after the lamp has run
up to its operating temperature range, virtually no ozone is produced by the lamp, as a rule, due to the quartz glass absorption and the self-absorption of the plas-
ma.
LAMP COOLING:
1. All Photo-Optic metal halide lamp bases must be kept below 230˚C (446˚F) during operation to prevent premature lamp failure. If convection cooling is inadequate,
forced air-cooling may be used. Please see OSRAM literature for cooling requirements of specific lamp types.
2. If forced air-cooling is used, care must be taken to direct airflow at the bases only. Striking elsewhere on the lamp with the airflow will result in poor lamp per-
formance or premature failure.
3. Discoloration, surface pitting, and/or corrosion of the lamp connections indicates a thermal overload. To obtain optimum lamp performance, components exhibit-
ing these conditions must be cleaned or replaced.
LAMP REMOVAL:
•Turn off power to the lamp and allow lamp to cool (forced or convection) for a minimum of 30 minutes prior to shutting main fixture power and opening fixture.
Do not remove lamp until it has cooled.
Lamps should be placed in their original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See
"Lamp Transportation" and "Lamp Disposal" sections below for relevant information.
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
228
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
METAL HALIDE PHOTO-OPTIC LAMPS [HMI®, HMD®, HMP®, HSD®, HSR®, HTI®] (continued)
LAMP TRANSPORTATION:
1. All Photo-Optic metal halide lamps should be transported ONLYin their original packaging.
2. Transportation in non-original packaging can damage the lamp and void warranty.
3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLYin DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
MERCURY FILL OF Photo-Optic METAL HALIDE LAMPS:
Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin "hydrargyrum," a silvery shiny liquid metal at room temperature. In
humid air it is covered with a gray oxide skin. Of all metals it has the highest vapor pressure which increases exponentially with rising temperatures. For this rea-
son, mercury is volatile at room temperature. The colorless and odorless vapors produced are poisonous and heavier than air.
The inhalation (respiration) of mercury or mercury compounds as vapor or dust will lead to the damage of lungs, kidneys, and the nervous system. Apart from
inhalation, mercury can be transmitted through the skin (penetration) or through the gastro-intestinal tract (ingestion), which is also harmful.
The ACGIH TLVs are merely guidelines to assist in the control of health hazards. The ACGIH states that the TLVs refer to airborne concentrations of substances
and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without adverse health effects. Therefore, the
TLV for mercury should never be exceeded.
Analytical detection of mercury vapor is possible by means of gas/vapor detector tubes (rough measurement) or air-monitors that absorb mercury vapor.
OSRAM metal halide lamps have the following mercury contents:
Lamp Family Maximum Mercury Content (mg)
HMI 1200
HMP 70
HTI 180
HSR/HSD 110
HMD 520
PROPERTIES OF MERCURY:
Chemical symbol: Hg
Atomic number: 80
Molecular Weight: 200.59
Density: 13.6 g/cm3@ 20°C / 68°F
Melting Point: -39°C / -38.2°F
Boiling Point: 357°C / 674°F
•Vapor pressure: 160 Pa @ 20°C / 68°F
370 Pa @ 30°C / 86°F
823 Pa @ 40°C / 104°F
Concentration in air: 13.6 mg/m3@ 20°C / 68°F
29.6 mg/m3@ 30°C / 86°F
62.7 mg/m3@ 40°C / 104°F
CAS Registry Number: 7439-97-6
RCRA waste number: U151
Other Names: Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. State laws may differ in their disposal require-
ments for lamps.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities. It
is the responsibility of the waste generator to ensure proper classification and disposal of waste products.
VIP®SUPER HIGH PRESSURE MERCURY LAMPS (PHOTO-OPTIC)
WARNING:
In accordance with ANSI/IESNA Standard RP-27, VIP Super High Pressure Mercury Lamps are Risk Group 3 products.
Read and understand this entire statement before using this lamp!
RUPTURE & RADIATION (UV- VISIBLE) HAZARD:
1. The discharge vessel of Super High Pressure Mercury VIP lamps is constructed of quartz glass that is filled with a quantity of mercury. These lamps are not pres-
surized when cold (i.e., at room temperature).
2. All Super High Pressure Mercury VIP lamps have high internal pressures (up to approximately 3,675 psi or 250 bar) during operation and may unexpectedly
rupture resulting in the discharge of hot fragments (approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of mercury/mer-
cury vapor. In the event of such a rupture, there is a risk of personal injury, burns, and fire.
3. Super High Pressure Mercury VIP lamps generate intense ultraviolet (UV), visible and infrared radiation during operation. This radiation can cause per-
manent damage to the eyes (including blindness) and serious injury to the skin (including burns and blistering). To avoid eye damage, other personal injury,
and/or property damage, the lamp MUST be operated in a suitable fixture.
4. A suitable fixture is one that will prevent the arc from being viewed directly while operating, and in the event of a lamp rupture, will prevent hot (up to 800°C /
1472°F), flying fragments of quartz and/or metal from escaping into the area.
5. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life).
WARNING
Lamp Contains Mercury
Hg Manage in accordance with disposal laws
See www.lamprecycle.orgor 1-866-666-6850
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
229
VIP®SUPER HIGH PRESSURE MERCURY LAMPS (PHOTO-OPTIC) (continued)
BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):
1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor. The area should then
be thoroughly ventilated for a minimum of 30 minutes or until the mercury vapor in the area is below the ACGIH TLV (American Conference of Governmental
Industrial Hygienists Threshold Limit Value). Inhaling vapor or small particles of mercury or its compounds can be harmful to lungs, kidneys, and nervous system.
Penetration of the skin or ingestion can also be harmful.
2. When the lamp housing has cooled, mercury residue may be picked up with special mercury adsorptive agents or a mercury vacuum cleaner (available from labo-
ratory safety equipment suppliers) and disposed of in accordance with local, state, and federal regulations. There should be no direct skin contact with and/or
inhalation of mercury residues that may be residing in lamp housing, optics or lamp parts.
3. If a cold (room temperature) lamp is broken, proceed with clean-up and disposal as indicated in item 2 above.
GENERAL SAFETY & INSTALLATION TIPS
INSTALLATION:
1. Do not use if lamp or any lamp parts such as reflector, front glass, etc. are scratched, cracked, or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. If the quartz parts are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a soft, clean, lint-free cloth. Do not use cleaning rags
or material that can leave a residue.
4. To prevent skin burns, allow lamp to cool before handling.
5. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion.
6. Super High Pressure Mercury VIP lamps should not be subjected to force/stress during installation.
7. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury, or property damage.
8. Use only in instruments/equipment specifying this light source.
9. Make sure lamp is properly connected to avoid damaging lamp and/or socket/connector. Electrical connections should be free from dirt and corrosion.
Socket/connector condition may affect lamp life.
10. Replace socket/connector or lamp if deterioration (pitting, scorching, corrosion, etc.) of either is observed.
OPERATION:
1. Super High Pressure Mercury VIP lamps are designed for operation on AC only.
2. Operate with compatible power supply and fixture only.
3. Super High Pressure Mercury VIP lamps need approximately 5 minutes (depending on lamp type and cooling conditions) before they reach their operating temper-
atures. To ensure proper ignition on the following start-up, lamps should not be switched off during the warm-up period.
4. The average service life of Super High Pressure Mercury VIP lamps is influenced by their ON/OFF-duty cycle. Lamp performance is reduced with increased duty
cycle.
OPERATING POSITION:
Super High Pressure Mercury VIP lamps may only be operated in the positions described in the OSRAM SYLVANIA product catalog and/or technical literature.
LAMP COOLING:
1. To prevent premature failure, forced-air cooling is required. Maximum permitted lamp temperatures are described in the available technical literature.
2. Discoloration, surface pitting, and/or corrosion of the lamp connections indicate a thermal overload. Components exhibiting these conditions must be cleaned or
replaced.
LAMP REMOVAL:
Turn off power to the lamp and allow lamp to cool (forced) for a minimum of 15 minutes prior to shutting main fixture power and opening fixture. Do not remove
lamp until it has cooled.
LAMP TRANSPORTATION:
1. All Super High Pressure Mercury VIP lamps should be transported ONLYin their original packaging.
2. Transportation in non-original packaging can result in damage to the lamp thus voiding the warranty.
3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLYin DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
MERCURY FILL OF SUPER HIGH PRESSURE MERCURY VIP LAMPS:
Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin "hydrargyrum," a silvery, shiny liquid metal at room temperature. In
humid air it is covered with a gray oxide skin. Of all metals it has the highest vapor pressure which increases exponentially with rising temperatures. For this rea-
son, mercury is volatile at room temperature. The colorless and odorless vapors produced are poisonous and heavier than air.
The inhalation (respiration) of mercury or mercury compounds as vapor or dust may lead to the damage of lungs, kidneys, and the nervous system. Apart from
inhalation, mercury can be transmitted through the skin (penetration) or through the gastro-intestinal tract (ingestion), which is also harmful.
Threshold Limit Values (TLVs) are not fine lines between safe and dangerous concentrations but are guidelines to assist in the control of health hazards. They rep-
resent the maximum exposure to substances, both short-term and long-term, that a person may experience without resulting in health-related problems.
Therefore, the TLV for mercury should never be exceeded.
Analytical detection of mercury vapor is possible by means of gas/vapor detector tubes (rough measurement) or air-monitors that absorb mercury vapor.
OSRAM Super High Pressure Mercury VIP lamps have the following mercury contents:
Power level Maximum Mercury content (mg)
100-200W 12
PROPERTIES OF MERCURY:
Chemical symbol: Hg
Atomic number: 80
Molecular Weight: 200.59
Density: 13.6 g/cm3@ 20°C / 68°F
Melting Point: -39°C / -38.2°F
•Boiling Point: 357°C / 674°F
•Vapor pressure: 160 Pa @ 20°C / 68°F
370 Pa @ 30°C / 86°F
823 Pa @ 40°C / 104°F
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
230
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
VIP®SUPER HIGH PRESSURE MERCURY LAMPS (PHOTO-OPTIC) (continued)
Concentration in air: 13.6 mg/m3@ 20°C / 68°F
29.6 mg/m3@ 30°C / 86°F
62.7 mg/m3@ 40°C / 104°F
CAS Registry Number: 7439-97-6
RCRA waste number: U151
Other Names: Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. Some U.S. states differ in their disposal require-
ments for lamps containing mercury.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA INC. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
XBO®HIGH PRESSURE XENON LAMPS
WARNING:
In accordance with ANSI/IESNA Standard RP-27, this XBO bulb is a Risk Group 3 product.
Read and understand this warning before using this bulb!
XBO lamps are at high internal pressure when cold (up to 35 bar or approximately 525 psi) and at operating temperature (up to 80 bar or approximately 1200 psi
at bulb wall temperatures of 600°C to 800°C). Therefore, XBO lamps may unexpectedly rupture resulting in the discharge of hot fragments of quartz and/or glass
and metal. In the event of such a rupture, there is a risk of personal injury, burns and fire. Only handle lamps with their protective covers in place. Do not han-
dle lamps without their protective covers unless government-approved (OSHA-approved in the U.S.A.) safety glasses, facemask (with neck protector), chest pro-
tector, and gauntlets are worn.
RUPTURE & RADIATION (UV-VISIBLE-IR) HAZARDS:
1. Intense ultraviolet (UV), visible, and infrared (IR) radiation is also generated during operation. This radiation can cause permanent damage to the eyes (including
blindness) and serious injury to the skin (including burns and blistering). Some operating lamps also generate ozone (O3). Others, designated "OFR," are con-
structed of materials that prevent the generation of ozone. See the "Ozone Generation" section below.
2. To avoid eye damage, other personal injury and/or property damage, the lamp MUST be operated in a suitable fixture. A suitable fixture is one that will prevent the
arc from being viewed directly while operating. It is ventilated to the outside for those lamps that produce ozone and, in the event of a rupture, will prevent hot
(up to 800°C), flying fragments of quartz and/or glass or metal from escaping into the surrounding area.
3. To minimize the risk of a lamp rupture, the lamp must be replaced at or before the end of rated life (see catalog for rated life) or when the lamp shows signs of
advanced blackening or quartz devitrification (recrystalization, a white, frosted appearance).
4. XBO lamps are constructed of quartz glass, tungsten electrodes and either tungsten support rods or molybdenum foils. High wattage XBO lamps used for cinema
film projection have nickel-plated end caps (bases). Reflectorized XBO lamps have a dichroic-coated borosilicate glass reflector.
GENERAL SAFETY & INSTALLATION TIPS
INSTALLATION:
1. Do not use if lamp is scratched, cracked, or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands.
4. Handle lamp ONLY with suitable, clean, safety gloves. See special handling instructions for using government-approved personal protective safety equipment with
high-pressure lamps.
5. If the quartz parts (or the reflector for reflectorized lamps) are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a soft, clean,
lint-free cloth. Do not use cleaning rags or material that can leave a residue.
6. To prevent skin burns, allow lamp to cool before handling.
7. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion along its
axis. For this reason, XBO lamps should be fixed at one end only and the electrical connection on the other end must be flexible enough to avoid stressing the
lamp.
8. XBO lamps should not be subjected to force/stress during installation.
9. Handle lamp only with protective safety cover in place. When installing lamp, remove safety cover only AFTER fully securing lamp in lamphouse/fixture and imme-
diately preceding the replacement of equipment covers or closing of lamphouse door.
10. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury, and/or property damage.
11. Use only in instruments/equipment specifying this lamp type.
12. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector.
Electrical connections should be free from dirt and corrosion.
13. Socket/connector condition may affect lamp life. Replace socket/connector or lamp if deterioration (pitting, scorching, corrosion, etc.) of either is observed.
14. All XBO lamps are designed for DC operation. Make sure that the polarity is correct before turning power on. Incorrect polarity can destroy the lamp in a matter
of seconds. Operate with compatible power supply and fixture only.
15. For best performance, operate this XBO lamp at rated current. Note: some low wattage XBO lamps may not be operated above their specified rated wattage. See
catalog for details.
16. For those XBO lamps that have a current control range, the current may be increased to its maximum value to compensate for loss of light over the life of the
lamp. Operating the lamp at minimum current does not prolong the life of the lamp. The DC current may only be varied within specified control limits for the
selected type. (See catalog for these limits for your specific lamp type.)
WARNING
Lamp Contains Mercury
Hg Manage in accordance with disposal laws
See www.lamprecycle.orgor 1-866-666-6850
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
231
XBO®HIGH PRESSURE XENON LAMPS (continued)
17. When installing bare lamps that have an included flat washer, slip the washer over the threaded pin on the cathode (- negative) side. Removal of this flat washer
(after half the average life) will allow a rotation of the lamp by 180° resulting in better output maintenance over life for horizontally operated lamps. This should be
done only if darkening is evident in the upper part of the bulb. In instances where bare lamp cathode bases are provided with two metal pins, they may be
engaged with the two slots on the protective cover to screw the cathode end of the lamp into its socket.
LAMP REMOVAL:
1. Turn off power to the lamp and allow it to cool (forced or convection) for a minimum of 15 minutes prior to shutting main fixture power and opening fixture.
Do not remove lamp until it has cooled. After the lamp has cooled, place the protective cover around it and reverse the procedure described above. See special
handling instructions for using government-approved safety equipment with high-pressure lamps.
2. Lamp should be placed in the original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See
"Lamp Disposal" section below for transportation and spent lamp disposal information.
OPERATING POSITION:
1. XBO bare lamps are designed to operate vertically. Of those, some (having an "H" in their designation) may also be operated in the horizontal position as well. For
vertically operated lamps, the anode (+ positive) electrode must be on the top. See catalog for operating position and permissible deviation for your specific type.
2. Some horizontally operated lamps require magnetic arc stabilization. Check the catalog for your specific lamp type.
3. XBO reflector lamps are designed to operate with lamp/reflector axis within 15° of the horizontal position.
LAMP COOLING:
1. Discoloration, surface pitting, and/or corrosion of the lamp indicates a thermal overload. Components exhibiting these conditions must be cleaned or replaced.
2. If forced-air cooling is used, care must be taken to direct airflow at the lamp bases only. Striking the lamp elsewhere with the airflow will result in poor lamp per-
formance or premature failure.
3. To prevent premature failure, the following cooling instructions must be followed:
Bare lamps - Bases must be kept below 230˚C (445˚F) during operation. If convection cooling is insufficient and additional cooling is required, forced air-cooling
may be used. If forced air is used, care must be taken to direct airflow at bases only, since striking elsewhere on the lamp with the airflow will result in poor lamp
performance or premature failure. See catalog for your specific lamp type to learn whether forced air-cooling is required.
Reflector lamps - To avoid damaging the reflector coating, do not allow the outer reflector surface to exceed the maximum temperature of 250°C (480˚F).
[Optimum temperature: 175-200°C (345-390˚F)] To prevent premature failure, the lamp ends must not exceed the maximum temperature of 350°C (660˚F).
[Optimum temperature: 200-250°C (385-480˚F)] Forced air-cooling is therefore required and the air flow must be directed perpendicular to the lamp/reflector axis,
through the slots in the openings of both ceramics. See catalog for diagram.
OZONE GENERATION:
An electrical discharge in xenon gas generates radiant energy ranging from approximately 140 nm in the UV region to far into the infrared region. Xenon lamps
are made of quartz glass. The quartz glass allows for the transmission of short UV wavelengths starting from approximately 140 nm, depending on the quartz
type. Ozone gas (O3) is generated by the conversion of oxygen (O2) in the air by UV energy in the range of approximately 110-200 nm. Ozone is extremely toxic
and will cause serious health problems if inhaled in excess of allowable limits over a prolonged period of time. For more information on allowable limits, please
refer to the ACGIH (American Conference of Governmental Industrial Hygienists) publication, "TLVs and BEIs" (Threshold Limit Values and Biological Exposure
Indices). Ozone production can be suppressed in xenon discharge lamps by adding materials to the quartz glass that block short-wave UV transmission.
QUARTZ GLASS DESIGN OPTIONS:
OSRAM XBO®xenon lamps are offered in three quartz glass designs. They are:
1. OSRAM XBO W/4: These lamps are fabricated from synthetic Suprasil quartz glass. Suprasil quartz is low in impurities and provides for maximum short-wave UV
transmission and consequently allows for the production of ozone. These lamps should always be used with external ventilation with no possible direct exposure
to humans. Under no circumstances may the applicable maximum allowable workplace concentration of ozone be exceeded for any OSRAM xenon XBO lamps.
2. OSRAM XBO: These lamps use standard quartz glass and will also emit UV radiation that produces ozone. These lamps, like the W/4 types, must always be
externally ventilated. With these types of lamps, health risks must always be minimized by suitably extracting the air from the lamp housing and externally vent-
ing it.
3. OSRAM XBO OFR: These lamps are designated "Ozone-Free" and are characterized by the letters "OFR" in the order description. OSRAM XBO OFR type lamps
have their quartz glass transparently coated to effectively suppress radiation below approximately 250 nm, resulting in the elimination of ozone production during
operation.
LAMP DISPOSAL:
1. There is a risk that a lamp could rupture because of its high internal pressure (both hot and at room temperature). A lamp rupture could result in personal injury
or property damage from flying fragments of glass and/or metal. Therefore, spent (end-of-life) lamps should ALWAYS be stored in the protective covers and pack-
aging in which they originally came, and ultimately depressurized before release for disposal. The following is one example of a depressurizing method for XBO
lamps prior to disposal, but it may not be the most suitable or appropriate method depending on the circumstance:
The operator must wear government-approved (OSHA-approved in the U.S.A.) safety glasses, facemask (with neck protector), chest protector, and
gauntlets during this entire procedure.
•With protective lamp covers in place, place lamps1into steel drum2and lock down cover with bolt ring and bolt.
•Drop drum onto solid surface (concrete floor) from at least five feet. Increase height as needed to ensure all lamps are depressurized.
•Wait for dust to settle (about 5 minutes) before opening drum. Loosen bolt and allow gas to escape before complete removal of cover.
1The lamps should not exceed the half-full point in the drums. Adjust the maximum number of lamps accordingly.
28, 20, or 30-gallon drums, depending on quantity of lamps to be de-pressurized, are available. Drums of 20-gauge steel are recommended and are available from many
safety supply companies.
2. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. State laws differ in their disposal requirements.
3. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
4. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
232
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
HBO®HIGH PRESSURE MERCURY LAMPS
WARNING:
In accordance with ANSI/IESNA Standard RP-27, this HBO bulb is a Risk Group 3 product.
Read and understand this warning before using this bulb!
RUPTURE & RADIATION (UV- VISIBLE) HAZARD:
1. The discharge vessel of HBO lamps is constructed of quartz glass that is filled with a quantity of mercury and either Argon or Xenon gas. Most HBO lamps are not
at positive pressure when cold (not operating, at room temperature). However, there are several HBO lamps that DO have a positive internal pressure of upto
approximately 8 bar (or approximately 120 psi) in the cold (room temperature) state. The printing of the following bold warning statement on individual packages
identifies them as positive-pressure lamps.
WARNING
RISK OF LAMP RUPTURING. TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, ALWAYS WEAR PROTECTIVE CLOTHING WHEN HANDLING THESE
LAMPS. Never handle these lamps unless government-approved (OSHA-approved in the U.S.A.) safety glasses, facemask (with neck protector), chest
protector, and gauntlets are worn.
These positive-pressure lamps may unexpectedly rupture resulting in the discharge of quartz and/or metal fragments as well as exposing the surrounding area to
mercury. In the event of such a rupture, there is a risk of personal injury or property damage. Therefore these positive-pressure lamps should be handled in
accordance with these safety instructions.
2. All HBO lamps have high internal pressures (400 - 1100 psi or 30 to 75 bar) during operation and may unexpectedly rupture resulting in the discharge of hot frag-
ments (approximately 800°C / 1472°F) of quartz and/or metal particles, as well as the release of mercury/mercury vapor. In the event of such a rupture, there is a
risk of personal injury, burns, and fire.
3. All HBO lamps generate intense ultraviolet (UV) and visible radiation during operation. This radiation can cause permanent damage to the eyes (including blind-
ness) and serious injury to the skin (including burns and blistering). To avoid eye damage, other personal injury, and/or property damage, the lamp MUST be
operated in a suitable fixture.
4. A suitable fixture is one that will prevent the arc from being viewed directly while operating, and in the event of a lamp rupture, will prevent hot (up to 800°C /
1472°F), flying fragments of quartz and/or metal from escaping into the area.
5. Fixtures for lamps that produce ozone during operation should be ventilated and filtered to the outside for ozone removal.
6. To minimize the risk of a lamp rupture, replace the lamp at or before the end of rated life (see OSRAM SYLVANIA product catalog for rated life) or when the lamp
shows signs of blackening.
BROKEN LAMPS (MERCURY VAPOR RELEASE AND DISPOSAL):
1. In the event of a lamp rupturing during operation, all personnel should leave the area immediately to avoid the inhalation of mercury vapor. The area should then
be thoroughly ventilated for a minimum of 30 minutes or until the mercury vapor in the area is below the ACGIH TLV (American Conference of Governmental
Industrial Hygienists Threshold Limit Value). Inhaling vapor or small particles of mercury or its compounds can be harmful to lungs, kidneys, and nervous system.
Penetration of the skin or ingestion can also be harmful.
2. To avoid mercury vapor getting into air conditioning systems, instruments/equipment using lamps of 350 watts or greater should be connected to separate air
exhaust systems through mercury vapor-absorbing filters. When the lamp housing has cooled, mercury residue may be picked up with special mercury adsorp-
tive agents or a mercury vacuum cleaner (available from laboratory safety equipment suppliers) and disposed of in accordance with local, state, and federal
regulations. There should be no direct skin contact with and/or inhalation of mercury residues that may be residing in lamp housing, optics or lamp parts.
If a cold (room temperature) lamp is broken, proceed with clean-up and disposal as indicated above (in the bold, italicized statement).
GENERAL SAFETY & INSTALLATION TIPS
INSTALLATION:
1. Do not use if lamp is scratched, cracked, or damaged in any way.
2. To prevent electric shock, shut off main power to the fixture before attempting to service or replace lamp.
3. To avoid damaging the quartz and causing premature lamp failure, do not handle lamp with bare hands.
4. Only handle lamp with suitable, clean safety gloves. See special, bolded warning for using government-approved safety equipment when handling positive-pres-
sure lamps.
5. If the quartz parts are inadvertently touched, clean fingerprints off with denatured alcohol and wipe dry with a soft, clean, lint-free cloth. Do not use cleaning rags
or material that can leave a residue.
6. To prevent skin burns, allow lamp to cool before handling.
7. To avoid breakage, mounting of the lamp must be free of mechanical stress during installation and during operation by allowing for thermal expansion along its
axis. For this reason, HBO lamps should be fixed at one end only and the electrical connection on the other end must be flexible enough to avoid stressing the
lamp.
8. HBO lamps should not be subjected to force/stress during installation.
9. Replace all fixture covers and shields after replacing lamp to prevent eye damage, other personal injury, or property damage.
10. Use only in instruments/equipment specifying this light source.
11. Make sure lamp is properly installed into socket/connector to obtain good electrical and thermal contact and avoid damaging lamp and/or socket/connector.
Electrical connections should be free from dirt and corrosion.
12. Socket/connector condition may affect lamp life. Replace socket/connector or lamp if deterioration (pitting, scorching, corrosion, etc.) of either is observed.
OPERATION:
1. Some HBO lamps are designed for operation on only AC or only DC while some are designed for operation on either AC or DC.
2. Note: all HBO lamps with power consumption of 350 W and higher are only suited for DC operation. Make sure that the polarity is correct before turning power on.
Incorrect polarity can destroy the lamp in a matter of seconds.
3. Operate with compatible power supply and fixture only.
4. To ensure that AC-suited lamps operate at correct power during AC operation, connections on the ballast/choke in the power supply should be made to the voltage
taps that are marked the same as the marking on the lamp base (L1 or L2). Some power supplies are equipped with a switch (or taps) for selecting L1 or L2. For
correct and safe lamp operation, use only those ballasts/power supplies that have been approved or meet minimum requirements as specified by OSRAM. See
your OSRAM dealer for list of approved equipment.
5. HBO lamps need 5 to 20 minutes (depending on lamp type and cooling conditions) before they reach their operating temperatures. To ensure proper ignition on
subsequent start-up, lamps should not be switched off during the warm-up period.
6. The average service life of high wattage HBO lamps (350 watts) is determined by their ON/OFF duty cycle. These lamps have been designed for a limited amount
of ignitions only (less than 10). Lamp performance is reduced with increased duty cycle.
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
233
HBO®HIGH PRESSURE MERCURY LAMPS (continued)
OPERATING POSITION:
HBO lamps may only be operated in the operating positions described in the OSRAM SYLVANIA product catalog.
Some HBO lamps are designed to operate horizontally (mainly low wattage types in the power range of 50 to 200 W) and others, vertically (all lamp types with-
power consumption of 350 W and higher). Greater arc stability is obtained in vertically operating lamps when they are operated as close to vertical as possible.
See catalog for permissible operating positions and electrode positions.
OZONE GENERATION:
During operation, HBO lamps produce a spectrum that ranges from about 150 nm in the ultraviolet region to the infrared region.
If the quartz glass bulb is transparent in the ultraviolet region between 180 and 220 nm, this short-wave radiation will convert a small quantity of atmospheric oxy-
gen (O2) surrounding the lamp into ozone (O3). Moreover, the oxygen molecules will link together with the nitrogen (N2) in the air, creating nitrogen oxides
(NOx). (Some believe that the smell attributed to ozone is in actuality from the nitrogen oxides.)
Ozone gas is toxic when inhaled in high concentrations over long periods of time. Ozone levels can be measured and monitored with commercial measuring
equipment. Always keep ozone levels below the applicable TLV (threshold limit value).
The production of ozone and nitrogen oxide can be suppressed by using doped quartz glass, which absorbs the ozone-producing ultraviolet radiation. The quartz
glass used in high wattage i-line (365nm) enhanced HBO lamps only transmits wavelengths above 250 nm, which provides effective, ozone-free lamps. Please be
advised that the OSRAM HBO 4000 W/PL lamp is designed to generate UV wavelengths below 250nm. Consequently, this lamp will generate ozone in operation
and should be externally ventilated.
An "ozone smell" (or smell of nitrogen oxide) may be detected shortly after ignition. There are two probable causes for this condition. O3and NOxproduction is
caused by the (short-duration) radiation of the spark gap used for lamp ignition. Or, the cold condition of the quartz glass bulb has slightly shifted its UV-absorp-
tion characteristics thus permitting a small amount of radiation in the very short-wave ultraviolet range to be emitted by the bulb. Typically, after the lamp has run
up to its operating temperature range, virtually no ozone is produced by the lamp, as a rule, due to the quartz glass absorption and the self-absorption of the plas-
ma.
LAMP COOLING:
1. To prevent premature failure, lamp base temperatures must be kept below 230˚C (446˚F) for 50 to 350 watt lamps and below 200˚C (392˚F) for all lamps with
power consumption of more than 350 watts.
2. Discoloration, surface pitting, and/or corrosion of the lamp connections indicates a thermal overload. Components exhibiting these conditions must be cleaned or
replaced.
3. If convection cooling is insufficient and additional cooling is required, cooling fins may be applied to the bases and/or forced air may be used.
4. If forced air is used, care must be taken to direct airflow at the bases only. Striking elsewhere on the lamp with the airflow will result in poor lamp performance or
premature failure.
LAMP REMOVAL:
Turn off power to the lamp and allow lamp to cool (forced or convection) for a minimum of 30 minutes prior to shutting main fixture power and opening fixture.
Do not remove lamp until it has cooled. See special, bolded warning for using government-approved safety equipment when handling positive-pressure lamps.
Lamps should be placed in their original OSRAM SYLVANIA packaging for temporary storage until disposal and/or transportation to a disposal location. See
"Lamp Transportation" and "Lamp Disposal" sections below for relevant information.
LAMP TRANSPORTATION:
1. All HBO lamps should be transported ONLYin their original packaging.
2. Transportation in non-original packaging can damage the lamp and void warranty.
3. U.S. Federal regulations require mercury-containing lamps to be shipped ONLYin DOT-compliant packaging. Original OSRAM packaging is DOT-compliant.
4. When transporting positive-pressure lamps, the bolded warning found in the "Rupture & Radiation Hazard" section MUST be placed on outside surface of the ship-
ping carton and the warning instructions must also be placed inside the shipping packaging.
MERCURY FILL OF HBO LAMPS:
Mercury is referred to by its chemical symbol, Hg, which is derived from the Greek and Latin "hydrargyrum," a silvery shiny liquid metal at room temperature. In
humid air it is covered with a gray oxide skin. Of all metals it has the highest vapor pressure which increases exponentially with rising temperatures. For this rea-
son, mercury is volatile at room temperature. The colorless and odorless vapors produced are poisonous and heavier than air.
The inhalation (respiration) of mercury or mercury compounds as vapor or dust will lead to the damage of lungs, kidneys, and the nervous system. Apart from
inhalation, mercury can be transmitted through the skin (penetration) or through the gastro-intestinal tract (ingestion), which is also harmful.
The ACGIH threshold limit values (TLVs) are merely guidelines to assist in the control of health hazards. The ACGIH says that the TLVs refer to airborne concentra-
tions of substances and represent conditions under which it is believed that nearly all workers may be repeatedly exposed day after day without adverse health
effects. Therefore, the TLV for mercury should never be exceeded.
Analytical detection of mercury vapor is possible by means of gas/vapor detector tubes (rough measurement) or air-monitors that absorb mercury vapor.
OSRAM HBO®lamps have the following mercury contents:
Power level Maximum Mercury content (mg)
50 - 200 W 110
350 W 300
500 W 500
1,000 W 600
1,500 W 800
2,000 - 2,500 W 5,000
3,500 W and higher 12,000
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
234
P
H
O
T
O
O
P
T
I
C
R
E
F
E
R
E
N
C
E
HBO®HIGH PRESSURE MERCURY LAMPS (continued)
PROPERTIES OF MERCURY:
Chemical symbol: Hg
Atomic number: 80
Molecular Weight: 200.59
Density: 13.6 g/cm3@ 20°C / 68°F
Melting Point: -39°C / -38.2°F
Boiling Point: 357°C / 674°F
•Vapor pressure: 160 Pa @ 20°C / 68°F
370 Pa @ 30°C / 86°F
823 Pa @ 40°C / 104°F
Concentration in air: 13.6 mg/m3@ 20°C / 68°F
29.6 mg/m3@ 30°C / 86°F
62.7 mg/m3@ 40°C / 104°F
CAS Registry Number: 7439-97-6
RCRA waste number: U151
Other Names: Hydrargyrum, Colloidal mercury, Kwik, Mercure, Mercurio, Metallic mercury, Quecksilber, Quick silver, Liquid Silver
LAMP DISPOSAL:
1. Disposal of spent lamps must be in accordance with applicable federal, state/provincial, and local regulations. State laws differ in their disposal requirements for
lamps containing mercury.
2. Lamp users in North America may obtain specific state or province information concerning disposal regulations, toll free, by calling 1-866-666-6850.
3. OSRAM SYLVANIA Products Inc. cannot advise lamp users as to general or specific disposal regulations for federal, state/provincial, and/or local municipalities.
Special disposal note for cold, positive-pressure lamps (see "RUPTURE & RADIATION HAZARD" section for applicable lamps)
There is a risk that these lamps could rupture because of their high internal pressure when hot (during operation) and when cold (at room temperature when not
operating). A lamp rupture could result in personal injury or property damage from flying fragments of quartz and/or metal. Therefore, spent (end-of-life) lamps
should ALWAYS be stored in the packaging in which they originally came.
Lamp Disposal Labeling
The following information appears on the packages and/or stuffer of mercury-containing Photo-Optic lamps. For more information
on lamp disposal labeling, see the inside back cover of this catalog.
Lamp Contains Mercury
Hg Manage in accordance with disposal laws
See www.lamprecycle.orgor 1-866-666-6850
Lamp Contains Mercury
Hg Manage in accordance with disposal laws
See www.lamprecycle.orgor 1-866-666-6850
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
235
Index by Ordering
Abbreviation
Type Page
1000Q/T6/RTPFS . . . . . . . . . . . . .179
1000T3Q/IR 230-250V . . . . . . . .179
1000T6QRTP/X . . . . . . . . . . . . . .179
1000TQ/RTP/CR/BULK . . . . . . . .179
120/T4/SPECIAL . . . . . . . . . . . . .175
1200T3Q/IR/CL/HT 144V . . . . . .179
1500Q/T6/RTPGS . . . . . . . . . . . .179
1600T3Q/IR 240V . . . . . . . . . . . .179
1600T3Q/IR 277V . . . . . . . . . . . .179
1600T3Q/IR/7 240V . . . . . . . . . .179
220T4Q/2PPF . . . . . . . . . . . . . . . .175
235T4Q/2PPF . . . . . . . . . . . . . . . .176
2500T3Q/IR 480V . . . . . . . . . . . .179
2500T3Q/IR/7 480V . . . . . . . . . .179
350PAR56/SP . . . . . . . . . . . . . . .179
3650T3Q/IR/CL 480V . . . . . . . . .179
3800T3Q/IR 570V . . . . . . . . . . . .179
4515 PAR36 30W . . . . . . . . . . . .178
4551 . . . . . . . . . . . . . . . . . . . . . . .179
4557 . . . . . . . . . . . . . . . . . . . . . . .180
4559 . . . . . . . . . . . . . . . . . . . . . . .179
500T3Q/IR 120V . . . . . . . . . . . . .179
500T3Q/IR/7 120V . . . . . . . . . . .179
5557 . . . . . . . . . . . . . . . . . . . . . . .180
6.6A/100T4/64341/HLX . . . . . . .180
6.6A/100T4/64341Z/HLX . . . . . .180
6.6A/100T4/64342/HLX . . . . . . .180
6.6A/105MR16/64339A . . . . . . .180
6.6A/105MR16/64339B . . . . . . .180
6.6A/105MR16/64339C . . . . . . .180
6.6A/115T4Q/58798/2PPF/EVV
. . . . . . . . . . . . . . . . . . . . . . . . . . . .180
6.6A/115T4Q/DCR/DL . . . . . . . . .180
6.6A/150T4/64361/HLX . . . . . . .180
6.6A/150T4Q/64354/EWR/DL . .180
6.6A/150T4Q/64361Z/HLX . . . . .180
6.6A/175T4Q/58799/2PPF/DL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .180
6.6A/200PAR64/2 . . . . . . . . . . . .180
6.6A/200PAR64Q/2P . . . . . . . . . .180
6.6A/200T4/64382/HLX . . . . . . .180
6.6A/200T4/64382A/HLX . . . . . .180
6.6A/200T4Q/2PPF/58750/EZL/DL
. . . . . . . . . . . . . . . . . . . . . . . . . . . .180
6.6A/200T4Q/64386 . . . . . . . . . .181
6.6A/200T4Q/CL/DCR/DL . . . . . .181
6.6A/200T5/CL/64380 . . . . . . . . .181
6.6A/204T14/2P . . . . . . . . . . . . . .181
6.6A/30MR16/64331A/SP . . . . .180
6.6A/30MR16/64331AC/FL . . . .180
6.6A/30T10/1P . . . . . . . . . . . . . . .180
6.6A/30T3.5/64322/EXL/DL . . . .180
6.6A/40MR11/64333B . . . . . . . .180
6.6A/45MR16/64337A45-15 . . .180
6.6A/45MR16/64337B45-15 . . .180
6.6A/45T10/P . . . . . . . . . . . . . . . .180
6.6A/45T3.5/64320/EXM . . . . . .180
6.6A/45T3.5Q/64321 . . . . . . . . . .180
6.6A/45T3/CL/64315 . . . . . . . . . .180
6.6A/45T4/64319 FEMALE . . . . .180
6.6A/45T4/64319Z . . . . . . . . . . . .180
6.6A/45T4/CL/64317 . . . . . . . . . .180
6.6A/48MR16/64337A48-15 . . .180
6.6A/48MR16/64338AC . . . . . . .180
Ordering Abbreviation Page
6.6A/65T4/64328Z/HLX . . . . . . .180
60T4QCL . . . . . . . . . . . . . . . . . . . .175
62138 HLX . . . . . . . . . . . . . . . . . .175
64223 . . . . . . . . . . . . . . . . . . . . . .175
64251 HLX . . . . . . . . . . . . . . . . . .175
64255 . . . . . . . . . . . . . . . . . . . . . .175
64258 HLX . . . . . . . . . . . . . . . . . .175
64260 . . . . . . . . . . . . . . . . . . . . . .175
64261 . . . . . . . . . . . . . . . . . . . . . .175
64265 HLX . . . . . . . . . . . . . . . . . .175
64275 . . . . . . . . . . . . . . . . . . . . . .175
64501 . . . . . . . . . . . . . . . . . . . . . .178
64514 . . . . . . . . . . . . . . . . . . . . . .179
64515 . . . . . . . . . . . . . . . . . . . . . .178
64516/300T6/CL . . . . . . . . . . . . .179
64573 . . . . . . . . . . . . . . . . . . . . . .178
64575 . . . . . . . . . . . . . . . . . . . . . .178
64602 . . . . . . . . . . . . . . . . . . . . . .175
64611 HLX . . . . . . . . . . . . . . . . . .175
64614 . . . . . . . . . . . . . . . . . . . . . .178
64617 . . . . . . . . . . . . . . . . . . . . . .175
64617S . . . . . . . . . . . . . . . . . . . . .175
64621 HLX . . . . . . . . . . . . .175, 179
64624 . . . . . . . . . . . . . . . . . . . . . .175
64635 HLX . . . . . . . . . . . . . . . . . .175
64637 . . . . . . . . . . . . . . . . . . . . . .175
64638 HLX . . . . . . . . . . . . . . . . . .175
64650 . . . . . . . . . . . . . . . . . . . . . .175
64654 HLX . . . . . . . . . . . . . . . . . .175
64664 HLX . . . . . . . . . . . . . . . . . .175
64665 HLX . . . . . . . . . . . . . . . . . .175
70313 (390158) . . . . . . . . . . . . . .176
70314 (390153) . . . . . . . . . . . . . .176
70335 BULK . . . . . . . . . . . . . . . . .176
750/120/T5/RTP . . . . . . . . . . . . .179
8013 . . . . . . . . . . . . . . . . . . . . . . .176
8017 . . . . . . . . . . . . . . . . . . . . . . .176
8018 . . . . . . . . . . . . . . . . . . . . . . .176
8025 . . . . . . . . . . . . . . . . . . . . . . .176
8029 . . . . . . . . . . . . . . . . . . . . . . .176
8100 . . . . . . . . . . . . . . . . . . . . . . .176
85T3/RM . . . . . . . . . . . . . . . . . . . .175
91645 . . . . . . . . . . . . . . . . . . . . . .176
BAA . . . . . . . . . . . . . . . . . . . . . . . .172
BBA 118V . . . . . . . . . . . . . . . . . . .172
BCK . . . . . . . . . . . . . . . . . . . . . . . .172
BCM . . . . . . . . . . . . . . . . . . . . . . . .176
BHC/DYS/DYV . . . . . . . . . . . . . . .172
BHC/DYS/DYV/X . . . . . . . . . . . . .172
BHC/DYS/DYV-5 . . . . . . . . . . . . .172
BRJ/EVB 64633 HLX . . . . . . . . .172
BRL 64610 HLX . . . . . . . . . . . . . .172
BRL 64610 HLX BULK . . . . . . . .172
BRN . . . . . . . . . . . . . . . . . . . . . . . .172
BTL . . . . . . . . . . . . . . . . . . . . . . . .176
BTM . . . . . . . . . . . . . . . . . . . . . . . .176
BTN . . . . . . . . . . . . . . . . . . . . . . . .176
BTP . . . . . . . . . . . . . . . . . . . . . . . .176
BTR . . . . . . . . . . . . . . . . . . . . . . . .176
BVA . . . . . . . . . . . . . . . . . . . . . . . .172
BVE . . . . . . . . . . . . . . . . . . . . . . . .172
BVM 64540 . . . . . . . . . . . . . . . . .176
BVT . . . . . . . . . . . . . . . . . . . . . . . .176
BVV . . . . . . . . . . . . . . . . . . . . . . . .176
BVW . . . . . . . . . . . . . . . . . . . . . . .176
CAX . . . . . . . . . . . . . . . . . . . . . . . .172
Ordering Abbreviation Page
CBA . . . . . . . . . . . . . . . . . . . . . . . .172
CXZ . . . . . . . . . . . . . . . . . . . . . . . .176
CYV . . . . . . . . . . . . . . . . . . . . . . . .176
CYX . . . . . . . . . . . . . . . . . . . . . . . .176
DDK . . . . . . . . . . . . . . . . . . . . . . . .172
DDL . . . . . . . . . . . . . . . . . . . . . . . .172
DDM . . . . . . . . . . . . . . . . . . . . . . .172
DDS . . . . . . . . . . . . . . . . . . . . . . . .172
DED . . . . . . . . . . . . . . . . . . . . . . . .172
DEK/DFW . . . . . . . . . . . . . . . . . . .172
DNE . . . . . . . . . . . . . . . . . . . . . . . .172
DNF . . . . . . . . . . . . . . . . . . . . . . . .172
DNS/FMC . . . . . . . . . . . . . . . . . . .176
DNT/FMD . . . . . . . . . . . . . . . . . . .176
DPY . . . . . . . . . . . . . . . . . . . . . . . .176
DTA . . . . . . . . . . . . . . . . . . . . . . . .176
DTY . . . . . . . . . . . . . . . . . . . . . . . .176
DVY . . . . . . . . . . . . . . . . . . . . . . . .172
DWE . . . . . . . . . . . . . . . . . . . . . . .176
DWT . . . . . . . . . . . . . . . . . . . . . . .176
DXW . . . . . . . . . . . . . . . . . . . . . . .176
DYH . . . . . . . . . . . . . . . . . . . . . . . .172
DZE . . . . . . . . . . . . . . . . . . . . . . . .172
EBV 118V . . . . . . . . . . . . . . . . . . .172
ECA 120V . . . . . . . . . . . . . . . . . . .172
ECT 120V . . . . . . . . . . . . . . . . . . .172
EFM 64607 . . . . . . . . . . . . . . . . . .172
EFN 64615 HLX . . . . . . . . . . . . . .172
EFP 64627 HLX . . . . . . . . . . . . . .172
EFP/X 64629 HLX . . . . . . . . . . . .172
EFR 64634 HLX . . . . . . . . . . . . . .172
EFR-5/X 64620 HLX . . . . . . . . . .172
EFX . . . . . . . . . . . . . . . . . . . . . . . . .176
EGE . . . . . . . . . . . . . . . . . . . . . . . .176
EGG . . . . . . . . . . . . . . . . . . . . . . . .176
EGJ . . . . . . . . . . . . . . . . . . . . . . . .176
EGK . . . . . . . . . . . . . . . . . . . . . . . .176
EGN . . . . . . . . . . . . . . . . . . . . . . . .176
EGR . . . . . . . . . . . . . . . . . . . . . . . .177
EGT . . . . . . . . . . . . . . . . . . . . . . . .177
EGW 64535 . . . . . . . . . . . . . . . . .177
EHA . . . . . . . . . . . . . . . . . . . . . . . .172
EHC/EHB . . . . . . . . . . . . . . . . . . . .177
EHD . . . . . . . . . . . . . . . . . . . . . . . .177
EHE 64626 HLX . . . . . . . . . . . . . .173
EHF . . . . . . . . . . . . . . . . . . . . . . . .177
EHG . . . . . . . . . . . . . . . . . . . . . . . .177
EHJ 64655 HLX . . . . . . . . . . . . . .173
EHP . . . . . . . . . . . . . . . . . . . . . . . .177
EHR . . . . . . . . . . . . . . . . . . . . . . . .177
EHZ . . . . . . . . . . . . . . . . . . . . . . . .177
EJA . . . . . . . . . . . . . . . . . . . . . . . . .173
EJG . . . . . . . . . . . . . . . . . . . . . . . .177
EJL . . . . . . . . . . . . . . . . . . . . . . . . .173
EJM . . . . . . . . . . . . . . . . . . . . . . . .173
EJV . . . . . . . . . . . . . . . . . . . . . . . . .173
EKB . . . . . . . . . . . . . . . . . . . . . . . .177
EKE . . . . . . . . . . . . . . . . . . . . . . . .173
EKE/X . . . . . . . . . . . . . . . . . . . . . . .173
EKP/ENA . . . . . . . . . . . . . . . . . . . .173
ELC . . . . . . . . . . . . . . . . . . . . . . . .173
ELC 64653 HLX . . . . . . . . . . . . . .173
ELC-3/X . . . . . . . . . . . . . . . . . . . . .173
ELC-7/X . . . . . . . . . . . . . . . . . . . . .173
ELC-7/X BULK . . . . . . . . . . . . . . .173
ELC-HL . . . . . . . . . . . . . . . . . . . . .173
Ordering Abbreviation Page
ELD . . . . . . . . . . . . . . . . . . . . . . . .173
ELH . . . . . . . . . . . . . . . . . . . . . . . .173
ELS . . . . . . . . . . . . . . . . . . . . . . . .173
ELV . . . . . . . . . . . . . . . . . . . . . . . . .173
ELZ . . . . . . . . . . . . . . . . . . . . . . . . .173
EMG . . . . . . . . . . . . . . . . . . . . . . . .173
EMM/EKS . . . . . . . . . . . . . . . . . . .173
ENG . . . . . . . . . . . . . . . . . . . . . . . .173
ENH . . . . . . . . . . . . . . . . . . . . . . . .173
ENH-5 . . . . . . . . . . . . . . . . . . . . . .173
ENL . . . . . . . . . . . . . . . . . . . . . . . .173
ENX . . . . . . . . . . . . . . . . . . . . . . . .173
ENX-5 . . . . . . . . . . . . . . . . . . . . . .173
ENX-7 . . . . . . . . . . . . . . . . . . . . . .173
EPR . . . . . . . . . . . . . . . . . . . . . . . .173
EPS . . . . . . . . . . . . . . . . . . . . . . . .173
EPS/230 . . . . . . . . . . . . . . . . . . . .173
EPT . . . . . . . . . . . . . . . . . . . . . . . .173
EPV . . . . . . . . . . . . . . . . . . . . . . . .173
EPX . . . . . . . . . . . . . . . . . . . . . . . .174
EPZ . . . . . . . . . . . . . . . . . . . . . . . .174
ERK BULK . . . . . . . . . . . . . . . . . . .174
ERM BULK . . . . . . . . . . . . . . . . . .174
ESA/FHD 64225 . . . . . . . . . . . . . .174
ESB 64250 HLX . . . . . . . . . . . . . .174
ETJ . . . . . . . . . . . . . . . . . . . . . . . . .174
EVA 64623 HLX . . . . . . . . . . . . . .174
EVC 64657 HLX . . . . . . . . . . . . . .174
EVD 64663 HLX . . . . . . . . . . . . . .174
EVD 64663 HLX BULK . . . . . . . .174
EVW . . . . . . . . . . . . . . . . . . . . . . . .174
EXC/230 . . . . . . . . . . . . . . . . . . . .178
EXC/240 . . . . . . . . . . . . . . . . . . . .178
EXD/230 . . . . . . . . . . . . . . . . . . . .178
EXD/240 . . . . . . . . . . . . . . . . . . . .178
EXE/230 . . . . . . . . . . . . . . . . . . . .178
EXE/240 . . . . . . . . . . . . . . . . . . . .179
EXG/230 . . . . . . . . . . . . . . . . . . . .179
EXR . . . . . . . . . . . . . . . . . . . . . . . .174
EXR BULK . . . . . . . . . . . . . . . . . . .174
EXW . . . . . . . . . . . . . . . . . . . . . . . .174
EXY . . . . . . . . . . . . . . . . . . . . . . . .174
EYB . . . . . . . . . . . . . . . . . . . . . . . .174
EYB-5 . . . . . . . . . . . . . . . . . . . . . .174
EYB-7 . . . . . . . . . . . . . . . . . . . . . .174
EZE . . . . . . . . . . . . . . . . . . . . . . . . .174
FAD . . . . . . . . . . . . . . . . . . . . . . . .177
FAL . . . . . . . . . . . . . . . . . . . . . . . . .177
FBV . . . . . . . . . . . . . . . . . . . . . . . .174
FCB . . . . . . . . . . . . . . . . . . . . . . . .177
FCM . . . . . . . . . . . . . . . . . . . . . . . .177
FCR 64625 HLX . . . . . . . . . . . . . .174
FCS 64640 HLX . . . . . . . . . . . . . .174
FCS 64640 HLX BULK . . . . . . . .174
FDA . . . . . . . . . . . . . . . . . . . . . . . .177
FDB . . . . . . . . . . . . . . . . . . . . . . . .177
FDN . . . . . . . . . . . . . . . . . . . . . . . .177
FDS/DZE 64643 . . . . . . . . . . . . . .174
FDT 64628 . . . . . . . . . . . . . . . . . .174
FDV 64642 HLX . . . . . . . . . . . . . .174
FEL . . . . . . . . . . . . . . . . . . . . . . . . .177
FEP/220 . . . . . . . . . . . . . . . . . . . . .177
FEP/240 . . . . . . . . . . . . . . . . . . . . .177
FER . . . . . . . . . . . . . . . . . . . . . . . .177
FEV . . . . . . . . . . . . . . . . . . . . . . . . .177
FEX/230 64781 . . . . . . . . . . . . . .177
Ordering Abbreviation Page
FEX/240 64781 . . . . . . . . . . . . . .177
FEY . . . . . . . . . . . . . . . . . . . . . . . . .177
FFJ . . . . . . . . . . . . . . . . . . . . . . . . .177
FFM . . . . . . . . . . . . . . . . . . . . . . . .177
FFN . . . . . . . . . . . . . . . . . . . . . . . . .179
FFP . . . . . . . . . . . . . . . . . . . . . . . . .179
FFR . . . . . . . . . . . . . . . . . . . . . . . . .179
FFS . . . . . . . . . . . . . . . . . . . . . . . . .179
FFT . . . . . . . . . . . . . . . . . . . . . . . . .177
FHM . . . . . . . . . . . . . . . . . . . . . . . .177
FHS . . . . . . . . . . . . . . . . . . . . . . . .174
FKT/EYH . . . . . . . . . . . . . . . . . . . .174
FKW . . . . . . . . . . . . . . . . . . . . . . . .177
FLE . . . . . . . . . . . . . . . . . . . . . . . . .174
FLK . . . . . . . . . . . . . . . . . . . . . . . . .177
FLT . . . . . . . . . . . . . . . . . . . . . . . . .174
FMR . . . . . . . . . . . . . . . . . . . . . . . .177
FNS 64512 . . . . . . . . . . . . . . . . . .174
FNT 64656PT HLX . . . . . . . . . . .174
FNT 64656PT HLX BULK . . . . . .175
FRG . . . . . . . . . . . . . . . . . . . . . . . .177
FRK . . . . . . . . . . . . . . . . . . . . . . . .177
FRN 2000T8Q . . . . . . . . . . . . . . .179
FSG . . . . . . . . . . . . . . . . . . . . . . . .175
FSH . . . . . . . . . . . . . . . . . . . . . . . .177
FSX/230 . . . . . . . . . . . . . . . . . . . .175
FSY . . . . . . . . . . . . . . . . . . . . . . . .175
FTK . . . . . . . . . . . . . . . . . . . . . . . . .177
FVL . . . . . . . . . . . . . . . . . . . . . . . . .177
FVM . . . . . . . . . . . . . . . . . . . . . . . .177
FXL . . . . . . . . . . . . . . . . . . . . . . . . .175
FXL-HL . . . . . . . . . . . . . . . . . . . . .175
GCA . . . . . . . . . . . . . . . . . . . . . . . .177
GCB . . . . . . . . . . . . . . . . . . . . . . . .175
GCC . . . . . . . . . . . . . . . . . . . . . . . .175
GCD . . . . . . . . . . . . . . . . . . . . . . . .175
GKV . . . . . . . . . . . . . . . . . . . . . . . .178
GLA 575/115/2000 . . . . . . . . . . .178
GLC 575/115/300 . . . . . . . . . . . .178
GLF . . . . . . . . . . . . . . . . . . . . . . . .178
HBO 100 W/2 . . . . . . . . . . . . . . . .204
HBO 1000 W/CEL . . . . . . . . . . . .209
HBO 1000 W/D . . . . . . . . . . . . . .210
HBO 1000 W/G . . . . . . . . . . . . . .209
HBO 1000 W/NEL . . . . . . . . . . . .209
HBO 1002 W/CEL . . . . . . . . . . . .209
HBO 1002 W/NEL . . . . . . . . . . . .210
HBO 1002 W/NIL . . . . . . . . . . . . .210
HBO 1003 W/PI . . . . . . . . . . . . . .210
HBO 1003 W/PIL . . . . . . . . . . . . .210
HBO 103 W/2 . . . . . . . . . . . . . . . .205
HBO 1500 W/CI . . . . . . . . . . . . . .211
HBO 1500 W/CIEL . . . . . . . . . . . .211
HBO 1500 W/CIL . . . . . . . . . . . . .211
HBO 1500 W/PI . . . . . . . . . . . . . .211
HBO 1500 W/PIL . . . . . . . . . . . . .211
HBO 200 W/2 L1 . . . . . . . . . . . . .205
HBO 200 W/2 L2 . . . . . . . . . . . . .205
HBO 200 W/2 TM L1 . . . . . . . . .206
HBO 200 W/2 TM L2 . . . . . . . . .206
HBO 200 W/4 . . . . . . . . . . . . . . . .206
HBO 200 W/DC . . . . . . . . . . . . . .206
HBO 2000 W/NIL . . . . . . . . . . . . .212
HBO 2001 W/CIEL . . . . . . . . . . . .212
HBO 2001 W/CIL . . . . . . . . . . . . .213
HBO 2001 W/NIEL . . . . . . . . . . .212
P
H
O
T
O
O
P
T
I
C
I
N
D
E
X
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
236
P
H
O
T
O
O
P
T
I
C
I
N
D
E
X
Index by Ordering
Abbreviation (cont.)
Type Page
HBO 2001 W/NIL . . . . . . . . . . . . .212
HBO 2002 W/MA . . . . . . . . . . . . .213
HBO 2002 W/NIL . . . . . . . . . . . . .212
HBO 201 W/HS-D2 . . . . . . . . . . .207
HBO 2011 W/NIL . . . . . . . . . . . . .213
HBO 202 W/4 . . . . . . . . . . . . . . . .207
HBO 250 W/BY . . . . . . . . . . . . . .208
HBO 250 W/HS . . . . . . . . . . . . . .207
HBO 2500 W/PIL . . . . . . . . . . . . .213
HBO 2501 W/NIL . . . . . . . . . . . . .214
HBO 2510 W/NIL . . . . . . . . . . . . .214
HBO 2700 W/CIL . . . . . . . . . . . . .214
HBO 350 W . . . . . . . . . . . . . . . . .208
HBO 350 W/S . . . . . . . . . . . . . . . .208
HBO 3500 W/PI . . . . . . . . . . . . . .214
HBO 3500 W/PIL . . . . . . . . . . . . .215
HBO 3501 W/PI . . . . . . . . . . . . . .215
HBO 3501 W/PIL . . . . . . . . . . . . .215
HBO 450 W/GS . . . . . . . . . . . . . .208
HBO 4500 W/CIL . . . . . . . . . . . . .215
HBO 50 W AC L1 . . . . . . . . . . . . .204
HBO 50 W AC L2 . . . . . . . . . . . . .204
HBO 50 W/3 . . . . . . . . . . . . . . . . .204
HBO 500 W/A . . . . . . . . . . . . . . . .208
HBO 500 W/B . . . . . . . . . . . . . . . .209
HBO 5500 W/PI . . . . . . . . . . . . . .215
HBO R 103 W/45 . . . . . . . . . . . . .205
HMI 1200 W/GS . . . . . . . . . . . . .183
HMI 1200 W/S . . . . . . . . . . . . . . .183
HMI 1200 W/SE . . . . . . . . . . . . . .182
HMI 12000 W/GS . . . . . . . . . . . .183
HMI 12000 W/SE . . . . . . . . . . . .182
HMI 123 W . . . . . . . . . . . . . . . . . .182
HMI 18000 W . . . . . . . . . . . . . . .183
HMI 200 W . . . . . . . . . . . . . . . . . .183
HMI 200 W/SE . . . . . . . . . . . . . . .182
HMI 250 W/SE . . . . . . . . . . . . . . .182
HMI 2500 W/GS . . . . . . . . . . . . .183
HMI 2500 W/S . . . . . . . . . . . . . . .183
HMI 2500 W/SE . . . . . . . . . . . . . .182
HMI 400 W/SE . . . . . . . . . . . . . . .182
HMI 4000 W . . . . . . . . . . . . . . . . .183
HMI 4000 W/SE . . . . . . . . . . . . . .182
HMI 575 W/GS . . . . . . . . . . . . . .183
HMI 575 W/SE . . . . . . . . . . . . . . .182
HMI 6000 W . . . . . . . . . . . . . . . . .183
HMI 6000 W/SE . . . . . . . . . . . . . .182
HMP 400 DE . . . . . . . . . . . . . . . .184
HMP 575 DE . . . . . . . . . . . . . . . .184
HMP 575 SE . . . . . . . . . . . . . . . . .184
HPL375/115 (UCF) . . . . . . . . . . .178
HPL375/115/X (UCF) . . . . . . . . .178
HPL550/64 (UCF) . . . . . . . . . . . .178
HPL550/77 (UCF) . . . . . . . . . . . .178
HPL550/77/X (UCF) . . . . . . . . . .178
HPL575/100 (UCF) . . . . . . . . . . .178
HPL575/115 (UCF) . . . . . . . . . . .178
HPL575/115/X (UCF) . . . . . . . . .178
HPL575/120 (UCF) . . . . . . . . . . .178
HPL575/120/X (UCF) . . . . . . . . .178
HPL575/230 (UCF) . . . . . . . . . . .178
HPL575/240 (UCF) . . . . . . . . . . .178
HPL750/115 (UCF) . . . . . . . . . . .178
HPL750/115/X (UCF) . . . . . . . . .178
Ordering Abbreviation Page
HPL750/120 (UCF) . . . . . . . . . . .178
HPL750/120/X (UCF) . . . . . . . . .178
HPL750/230 (UCF) . . . . . . . . . . .178
HPL750/240 (UCF) . . . . . . . . . . .178
HPL750/77 (UCF) . . . . . . . . . . . .178
HPR 575/115 . . . . . . . . . . . . . . . .178
HSD 150/70 . . . . . . . . . . . . . . . . .189
HSD 200 . . . . . . . . . . . . . . . . . . . .189
HSD 250/60 . . . . . . . . . . . . . . . . .189
HSD 250/78 . . . . . . . . . . . . . . . . .189
HSD 575/72 . . . . . . . . . . . . . . . . .189
HSR 1200/60 . . . . . . . . . . . . . . . .188
HSR 400/60 . . . . . . . . . . . . . . . . .188
HSR 575/60 . . . . . . . . . . . . . . . . .188
HSR 575/72 . . . . . . . . . . . . . . . . .188
HSR 700/60 . . . . . . . . . . . . . . . . .188
HTI 1200 W/SE . . . . . . . . . . . . . .186
HTI 150 W . . . . . . . . . . . . . . . . . .185
HTI 152 W . . . . . . . . . . . . . . . . . .185
HTI 250 W/22 . . . . . . . . . . . . . . . .187
HTI 250 W/32 . . . . . . . . . . . . . . . .187
HTI 250 W/32C . . . . . . . . . . . . . .187
HTI 250 W/SE . . . . . . . . . . . . . . .185
HTI 2500 W/SE . . . . . . . . . . . . . .186
HTI 300 W/DEL . . . . . . . . . . . . . .187
HTI 300 W/DX . . . . . . . . . . . . . . .187
HTI 400 W/24 . . . . . . . . . . . . . . . .187
HTI 400 W/SE . . . . . . . . . . . . . . .185
HTI 4000 W/DE . . . . . . . . . . . . . .187
HTI 403 W/24 . . . . . . . . . . . . . . . .187
HTI 404 W/SE . . . . . . . . . . . . . . .185
HTI 405 W/SE . . . . . . . . . . . . . . .186
HTI 600 W/D . . . . . . . . . . . . . . . .187
HTI 600 W/SE . . . . . . . . . . . . . . .186
HTI 700 W/DE . . . . . . . . . . . . . . .187
HTI 705 W/SE . . . . . . . . . . . . . . .186
HTI S 35/12 . . . . . . . . . . . . . . . . .185
Na 10 FL . . . . . . . . . . . . . . . . . . . .216
Q4559 . . . . . . . . . . . . . . . . . . . . . .179
Q4559X . . . . . . . . . . . . . . . . . . . . .180
Q4681 . . . . . . . . . . . . . . . . . . . . . .179
STUDIOLINE 55W/3200 . . . . . . .178
STUDIOLINE 55W/5600 . . . . . . .178
VIP R 273/45 . . . . . . . . . . . . . . . .190
VIP S 170/13 . . . . . . . . . . . . . . . .190
XBO 100 W OFR . . . . . . . . . . . . .191
XBO 1000 W/HS OFR . . . . . . . . .196
XBO 1000 W/HSC OFR . . . . . . . .196
XBO 1000 W/HTP OFR . . . . . . . .197
XBO 10000 W/C OFR . . . . . . . . .203
XBO 10000 W/HS OFR . . . . . . . .203
XBO 150 W/1 . . . . . . . . . . . . . . . .192
XBO 150 W/1 OFR . . . . . . . . . . .192
XBO 150 W/4 . . . . . . . . . . . . . . . .192
XBO 150 W/CR OFR . . . . . . . . . .193
XBO 150 W/S . . . . . . . . . . . . . . . .193
XBO 1600 W OFR . . . . . . . . . . . .197
XBO 1600 W/CA OFR . . . . . . . . .197
XBO 1600 W/HS OFR . . . . . . . . .197
XBO 1600 W/HSC OFR . . . . . . . .197
XBO 2000 W/H OFR . . . . . . . . . .198
XBO 2000 W/HS OFR . . . . . . . . .198
XBO 2000 W/HTP OFR . . . . . . . .198
XBO 2000 W/SHSC OFR . . . . . .198
XBO 2001 W/HTP OFR . . . . . . . .198
XBO 250 W OFR . . . . . . . . . . . . .194
Ordering Abbreviation Page
XBO 2500 W OFR . . . . . . . . . . . .199
XBO 2500 W/HS OFR . . . . . . . . .199
XBO 3000 W/H OFR . . . . . . . . . .199
XBO 3000 W/HS OFR . . . . . . . . .199
XBO 3000 W/HTP OFR . . . . . . . .199
XBO 4000 W OFR . . . . . . . . . . . .200
XBO 4000 W/HS OFR . . . . . . . . .200
XBO 4000 W/HTP OFR . . . . . . . .200
XBO 4200 W/CA OFR . . . . . . . . .200
XBO 4200 W/GS OFR . . . . . . . . .200
XBO 450 W . . . . . . . . . . . . . . . . . .194
XBO 450 W OFR . . . . . . . . . . . . .195
XBO 450 W/1 . . . . . . . . . . . . . . . .195
XBO 450 W/2 OFR . . . . . . . . . . .195
XBO 450 W/4 . . . . . . . . . . . . . . . .195
XBO 4500 W/HS . . . . . . . . . . . . .201
XBO 4500 W/HTP . . . . . . . . . . . .201
XBO 500 W/H OFR . . . . . . . . . . .196
XBO 5000 W/H OFR . . . . . . . . . .201
XBO 5000 W/HTP OFR . . . . . . . .201
XBO 6000 W/HS OFR . . . . . . . . .202
XBO 6000 W/HTP OFR . . . . . . . .202
XBO 6500 W . . . . . . . . . . . . . . . .202
XBO 700 W/HS OFR . . . . . . . . . .196
XBO 7000 W/HS OFR . . . . . . . . .202
XBO 7000 W/HSH OFR . . . . . . .203
XBO 75 W/2 . . . . . . . . . . . . . . . . .191
XBO 75 W/2 OFR . . . . . . . . . . . . .191
XBO 8000 W/HS OFR . . . . . . . . .203
XBO 900 W OFR . . . . . . . . . . . . .196
XBO R 100 W/45 OFR . . . . . . . .191
XBO R 100 W/45C OFR . . . . . . .191
XBO R 101 W/45C OFR . . . . . . .192
XBO R 180 W/45/OFR . . . . . . . .193
XBO R 180 W/45C OFR . . . . . . .193
XBO R 181 W/45C OFR . . . . . . .194
XBO R 300 W/60C OFR . . . . . . .194
XERADEX 20 . . . . . . . . . . . . . . . .216
XERADEX 20/HV . . . . . . . . . . . . .216
XERADEX 20/SY45/45 . . . . . . . .216
Index by Product
Number
Type Page
11558 . . . . . . . . . . . . . . . . .172
11560 . . . . . . . . . . . . . . . . .172
11619 . . . . . . . . . . . . . . . . .172
13365 . . . . . . . . . . . . . . . . .172
14936 . . . . . . . . . . . . . . . . .179
14974 . . . . . . . . . . . . . . . . .179
14985 . . . . . . . . . . . . . . . . .180
14988 . . . . . . . . . . . . . . . . .180
14994 . . . . . . . . . . . . . . . . .180
15399 . . . . . . . . . . . . . . . . .179
17980 . . . . . . . . . . . . . . . . .180
17981 . . . . . . . . . . . . . . . . .180
17983 . . . . . . . . . . . . . . . . .181
20607 . . . . . . . . . . . . . . . . .178
20608 . . . . . . . . . . . . . . . . .178
53997 . . . . . . . . . . . . . . . . .176
53998 . . . . . . . . . . . . . . . . .175
53999 . . . . . . . . . . . . . . . . .175
54001 . . . . . . . . . . . . . . . . .178
54007 . . . . . . . . . . . . . . . . .179
54008 . . . . . . . . . . . . . . . . .179
54019 . . . . . . . . . . . . . . . . .174
54021 . . . . . . . . . . . . . . . . .175
54022 . . . . . . . . . . . . . . . . .175
54023 . . . . . . . . . . . . . . . . .175
54025 . . . . . . . . . . . . . . . . .174
54026 . . . . . . . . . . . . . . . . .175
54027 . . . . . . . . . . . . . . . . .175
54028 . . . . . . . . . . . . . . . . .175
54031 . . . . . . . . . . . . . . . . .174
54032 . . . . . . . . . . . . .175, 179
54034 . . . . . . . . . . . . . . . . .172
54035 . . . . . . . . . . . . . . . . .172
54036 . . . . . . . . . . . . . . . . .174
54038 . . . . . . . . . . . . . . . . .173
54039 . . . . . . . . . . . . . . . . .172
54041 . . . . . . . . . . . . . . . . .174
54042 . . . . . . . . . . . . . . . . .174
54044 . . . . . . . . . . . . . . . . .174
54045 . . . . . . . . . . . . . . . . .173
54046 . . . . . . . . . . . . . . . . .175
54047 . . . . . . . . . . . . . . . . .174
54050 . . . . . . . . . . . . . . . . .175
54052 . . . . . . . . . . . . . . . . .174
54054 . . . . . . . . . . . . . . . . .174
54055 . . . . . . . . . . . . . . . . .174
54056 . . . . . . . . . . . . . . . . .175
54057 . . . . . . . . . . . . . . . . .175
54058 . . . . . . . . . . . . . . . . .175
54059 . . . . . . . . . . . . . . . . .182
54060 . . . . . . . . . . . . . . . . .183
54061 . . . . . . . . . . . . . . . . .182
54062 . . . . . . . . . . . . . . . . .182
54063 . . . . . . . . . . . . . . . . .182
54066 . . . . . . . . . . . . . . . . .183
54067 . . . . . . . . . . . . . . . . .182
54068 . . . . . . . . . . . . . . . . .183
54069 . . . . . . . . . . . . . . . . .183
54070 . . . . . . . . . . . . . . . . .182
54071 . . . . . . . . . . . . . . . . .183
54072 . . . . . . . . . . . . . . . . .182
54073 . . . . . . . . . . . . . . . . .183
54074 . . . . . . . . . . . . . . . . .183
54075 . . . . . . . . . . . . . . . . .183
Product Number Page
54078 . . . . . . . . . . . . . . . . .185
54079 . . . . . . . . . . . . . . . . .185
54080 . . . . . . . . . . . . . . . . .187
54081 . . . . . . . . . . . . . . . . .187
54083 . . . . . . . . . . . . . . . . .187
54084 . . . . . . . . . . . . . . . . .185
54087 . . . . . . . . . . . . . . . . .186
54088 . . . . . . . . . . . . . . . . .183
54089 . . . . . . . . . . . . . . . . .187
54091 . . . . . . . . . . . . . . . . .185
54098 . . . . . . . . . . . . . . . . .183
54099 . . . . . . . . . . . . . . . . .182
54100 . . . . . . . . . . . . . . . . .174
54102 . . . . . . . . . . . . . . . . .188
54103 . . . . . . . . . . . . . . . . .174
54104 . . . . . . . . . . . . . . . . .187
54106 . . . . . . . . . . . . . . . . .185
54107 . . . . . . . . . . . . . . . . .188
54112 . . . . . . . . . . . . . . . . .187
54113 . . . . . . . . . . . . . . . . .182
54115 . . . . . . . . . . . . . . . . .188
54116 . . . . . . . . . . . . . . . . .188
54117 . . . . . . . . . . . . . . . . .187
54118 . . . . . . . . . . . . . . . . .189
54119 . . . . . . . . . . . . . . . . .189
54120 . . . . . . . . . . . . . . . . .175
54121 . . . . . . . . . . . . . . . . .175
54122 . . . . . . . . . . . . . . . . .175
54123 . . . . . . . . . . . . . . . . .172
54124 . . . . . . . . . . . . . . . . .175
54125 . . . . . . . . . . . . . . . . .175
54126 . . . . . . . . . . . . . . . . .172
54129 . . . . . . . . . . . . . . . . .189
54130 . . . . . . . . . . . . . . . . .186
54133 . . . . . . . . . . . . . . . . .187
54136 . . . . . . . . . . . . . . . . .175
54137 . . . . . . . . . . . . . . . . .182
54138 . . . . . . . . . . . . . . . . .175
54139 . . . . . . . . . . . . . . . . .186
54140 . . . . . . . . . . . . . . . . .187
54141 . . . . . . . . . . . . . . . . .186
54142 . . . . . . . . . . . . . . . . .186
54143 . . . . . . . . . . . . . . . . .187
54144 . . . . . . . . . . . . . . . . .184
54145 . . . . . . . . . . . . . . . . .184
54146 . . . . . . . . . . . . . . . . .184
54167 . . . . . . . . . . . . . . . . .189
54168 . . . . . . . . . . . . . . . . .188
54170 . . . . . . . . . . . . . . . . .189
54189 . . . . . . . . . . . . . . . . .172
54192 . . . . . . . . . . . . . . . . .172
54210 . . . . . . . . . . . . . . . . .172
54211 . . . . . . . . . . . . . . . . .172
54212 . . . . . . . . . . . . . . . . .173
54214 . . . . . . . . . . . . . . . . .175
54232 . . . . . . . . . . . . . . . . .178
54233 . . . . . . . . . . . . . . . . .175
54350 . . . . . . . . . . . . . . . . .177
54383 . . . . . . . . . . . . . . . . .174
54386 . . . . . . . . . . . . . . . . .174
54388 . . . . . . . . . . . . . . . . .174
54392 . . . . . . . . . . . . . . . . .174
54393 . . . . . . . . . . . . . . . . .174
54394 . . . . . . . . . . . . . . . . .174
54400 . . . . . . . . . . . . . . . . .175
54409 . . . . . . . . . . . . . . . . .172
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
237
Index by Product
Number (cont.)
Type Page
54411 . . . . . . . . . . . . . . . . .172
54412 . . . . . . . . . . . . . . . . .177
54428 . . . . . . . . . . . . . . . . .177
54430 . . . . . . . . . . . . . . . . .175
54432 . . . . . . . . . . . . . . . . .175
54434 . . . . . . . . . . . . . . . . .177
54435 . . . . . . . . . . . . . . . . .177
54436 . . . . . . . . . . . . . . . . .177
54440 . . . . . . . . . . . . . . . . .174
54441 . . . . . . . . . . . . . . . . .177
54442 . . . . . . . . . . . . . . . . .177
54446 . . . . . . . . . . . . . . . . .174
54448 . . . . . . . . . . . . . . . . .174
54455 . . . . . . . . . . . . . . . . .174
54459 . . . . . . . . . . . . . . . . .177
54460 . . . . . . . . . . . . . . . . .178
54466 . . . . . . . . . . . . . . . . .175
54471 . . . . . . . . . . . . . . . . .177
54483 . . . . . . . . . . . . . . . . .177
54488 . . . . . . . . . . . . . . . . .177
54499 . . . . . . . . . . . . . . . . .178
54500 . . . . . . . . . . . . . . . . .176
54506 . . . . . . . . . . . . . . . . .177
54507 . . . . . . . . . . . . . . . . .178
54508 . . . . . . . . . . . . . . . . .177
54510 . . . . . . . . . . . . . . . . .177
54511 . . . . . . . . . . . . . . . . .178
54512 . . . . . . . . . . . . . . . . .177
54514 . . . . . . . . . . . . . . . . .177
54515 . . . . . . . . . . . . . . . . .177
54516 . . . . . . . . . . . . . . . . .178
54518 . . . . . . . . . . . . . . . . .177
54528 . . . . . . . . . . . . . . . . .172
54532 . . . . . . . . . . . . . . . . .177
54534 . . . . . . . . . . . . . . . . .177
54546 . . . . . . . . . . . . . . . . .179
54547 . . . . . . . . . . . . . . . . .174
54549 . . . . . . . . . . . . . . . . .178
54550 . . . . . . . . . . . . . . . . .177
54559 . . . . . . . . . . . . . . . . .177
54560 . . . . . . . . . . . . . . . . .179
54561 . . . . . . . . . . . . . . . . .172
54568 . . . . . . . . . . . . . . . . .174
54570 . . . . . . . . . . . . . . . . .177
54571 . . . . . . . . . . . . . . . . .177
54574 . . . . . . . . . . . . . . . . .177
54576 . . . . . . . . . . . . . . . . .172
54580 . . . . . . . . . . . . . . . . .172
54584 . . . . . . . . . . . . . . . . .179
54585 . . . . . . . . . . . . . . . . .172
54588 . . . . . . . . . . . . . . . . .179
54589 . . . . . . . . . . . . . . . . .177
54598 . . . . . . . . . . . . . . . . .177
54602 . . . . . . . . . . . . . . . . .178
54603 . . . . . . . . . . . . . . . . .178
54604 . . . . . . . . . . . . . . . . .178
54605 . . . . . . . . . . . . . . . . .178
54611 . . . . . . . . . . . . . . . . .178
54613 . . . . . . . . . . . . . . . . .176
54614 . . . . . . . . . . . . . . . . .178
54618 . . . . . . . . . . . . . . . . .178
54619 . . . . . . . . . . . . . . . . .178
54622 . . . . . . . . . . . . . . . . .178
54623 . . . . . . . . . . . . . . . . .178
Product Number Page
54625 . . . . . . . . . . . . . . . . .178
54629 . . . . . . . . . . . . . . . . .177
54631 . . . . . . . . . . . . . . . . .177
54633 . . . . . . . . . . . . . . . . .179
54636 . . . . . . . . . . . . . . . . .177
54647 . . . . . . . . . . . . . . . . .176
54648 . . . . . . . . . . . . . . . . .176
54649 . . . . . . . . . . . . . . . . .178
54652 . . . . . . . . . . . . . . . . .176
54653 . . . . . . . . . . . . . . . . .178
54654 . . . . . . . . . . . . . . . . .176
54655 . . . . . . . . . . . . . . . . .176
54656 . . . . . . . . . . . . . . . . .176
54658 . . . . . . . . . . . . . . . . .176
54659 . . . . . . . . . . . . . . . . .176
54660 . . . . . . . . . . . . . . . . .172
54662 . . . . . . . . . . . . . . . . .177
54664 . . . . . . . . . . . . . . . . .177
54673 . . . . . . . . . . . . . . . . .172
54685 . . . . . . . . . . . . . . . . .176
54686 . . . . . . . . . . . . . . . . .176
54687 . . . . . . . . . . . . . . . . .176
54688 . . . . . . . . . . . . . . . . .176
54689 . . . . . . . . . . . . . . . . .176
54690 . . . . . . . . . . . . . . . . .176
54691 . . . . . . . . . . . . . . . . .176
54692 . . . . . . . . . . . . . . . . .176
54694 . . . . . . . . . . . . . . . . .176
54696 . . . . . . . . . . . . . . . . .176
54698 . . . . . . . . . . . . . . . . .172
54706 . . . . . . . . . . . . . . . . .176
54711 . . . . . . . . . . . . . . . . .177
54716 . . . . . . . . . . . . . . . . .176
54717 . . . . . . . . . . . . . . . . .176
54723 . . . . . . . . . . . . . . . . .174
54726 . . . . . . . . . . . . . . . . .172
54729 . . . . . . . . . . . . . . . . .172
54730 . . . . . . . . . . . . . . . . .173
54732 . . . . . . . . . . . . . . . . .173
54734 . . . . . . . . . . . . . . . . .173
54737 . . . . . . . . . . . . . . . . .172
54743 . . . . . . . . . . . . . . . . .174
54745 . . . . . . . . . . . . . . . . .173
54747 . . . . . . . . . . . . . . . . .173
54752 . . . . . . . . . . . . . . . . .179
54753 . . . . . . . . . . . . . . . . .173
54755 . . . . . . . . . . . . . . . . .172
54765 . . . . . . . . . . . . . . . . .173
54776 . . . . . . . . . . . . . . . . .173
54787 . . . . . . . . . . . . . . . . .176
54804 . . . . . . . . . . . . . . . . .173
54807 . . . . . . . . . . . . . . . . .178
54810 . . . . . . . . . . . . . . . . .173
54811 . . . . . . . . . . . . . . . . .173
54812 . . . . . . . . . . . . . . . . .172
54813 . . . . . . . . . . . . . . . . .178
54814 . . . . . . . . . . . . . . . . .173
54815 . . . . . . . . . . . . . . . . .178
54816 . . . . . . . . . . . . . . . . .173
54817 . . . . . . . . . . . . . . . . .178
54822 . . . . . . . . . . . . . . . . .178
54825 . . . . . . . . . . . . . . . . .178
54828 . . . . . . . . . . . . . . . . .173
54829 . . . . . . . . . . . . . . . . .173
54835 . . . . . . . . . . . . . . . . .172
54836 . . . . . . . . . . . . . . . . .172
Product Number Page
54837 . . . . . . . . . . . . . . . . .177
54840 . . . . . . . . . . . . . . . . .173
54841 . . . . . . . . . . . . . . . . .173
54842 . . . . . . . . . . . . . . . . .173
54845 . . . . . . . . . . . . . . . . .175
54868 . . . . . . . . . . . . . . . . .172
54875 . . . . . . . . . . . . . . . . .177
54897 . . . . . . . . . . . . . . . . .175
54898 . . . . . . . . . . . . . . . . .175
54899 . . . . . . . . . . . . . . . . .175
54904 . . . . . . . . . . . . . . . . .175
54912 . . . . . . . . . . . . . . . . .175
54913 . . . . . . . . . . . . . . . . .173
54916 . . . . . . . . . . . . . . . . .173
54924 . . . . . . . . . . . . . . . . .172
54926 . . . . . . . . . . . . . . . . .173
54927 . . . . . . . . . . . . . . . . .174
54928 . . . . . . . . . . . . . . . . .174
54944 . . . . . . . . . . . . . . . . .172
54957 . . . . . . . . . . . . . . . . .173
54960 . . . . . . . . . . . . . . . . .173
54975 . . . . . . . . . . . . . . . . .173
54977 . . . . . . . . . . . . . . . . .173
54979 . . . . . . . . . . . . . . . . .174
54984 . . . . . . . . . . . . . . . . .173
54986 . . . . . . . . . . . . . . . . .173
54988 . . . . . . . . . . . . . . . . .173
55050 . . . . . . . . . . . . . . . . .174
55054 . . . . . . . . . . . . . . . . .174
56214 . . . . . . . . . . . . . . . . .179
56215 . . . . . . . . . . . . . . . . .179
56216 . . . . . . . . . . . . . . . . .179
56217 . . . . . . . . . . . . . . . . .179
56220 . . . . . . . . . . . . . . . . .180
56222 . . . . . . . . . . . . . . . . .179
56223 . . . . . . . . . . . . . . . . .180
56229 . . . . . . . . . . . . . . . . .179
56232 . . . . . . . . . . . . . . . . .178
56233 . . . . . . . . . . . . . . . . .178
56234 . . . . . . . . . . . . . . . . .179
56280 . . . . . . . . . . . . . . . . .178
56281 . . . . . . . . . . . . . . . . .178
56282 . . . . . . . . . . . . . . . . .179
56283 . . . . . . . . . . . . . . . . .178
58537 . . . . . . . . . . . . . . . . .180
58545 . . . . . . . . . . . . . . . . .180
58635 . . . . . . . . . . . . . . . . .174
58636 . . . . . . . . . . . . . . . . .178
58637 . . . . . . . . . . . . . . . . .177
58638 . . . . . . . . . . . . . . . . .176
58639 . . . . . . . . . . . . . . . . .178
58640 . . . . . . . . . . . . . . . . .178
58649 . . . . . . . . . . . . . . . . .180
58697 . . . . . . . . . . . . . . . . .180
58703 . . . . . . . . . . . . . . . . .180
58704 . . . . . . . . . . . . . . . . .180
58705 . . . . . . . . . . . . . . . . .180
58706 . . . . . . . . . . . . . . . . .180
58707 . . . . . . . . . . . . . . . . .181
58708 . . . . . . . . . . . . . . . . .180
58709 . . . . . . . . . . . . . . . . .180
58711 . . . . . . . . . . . . . . . . .180
58717 . . . . . . . . . . . . . . . . .180
58722 . . . . . . . . . . . . . . . . .180
58724 . . . . . . . . . . . . . . . . .180
58726 . . . . . . . . . . . . . . . . .180
Product Number Page
58729 . . . . . . . . . . . . . . . . .175
58730 . . . . . . . . . . . . . . . . .180
58758 . . . . . . . . . . . . . . . . .180
58759 . . . . . . . . . . . . . . . . .180
58771 . . . . . . . . . . . . . . . . .173
58775 . . . . . . . . . . . . . . . . .180
58777 . . . . . . . . . . . . . . . . .180
58779 . . . . . . . . . . . . . . . . .180
58782 . . . . . . . . . . . . . . . . .173
58785 . . . . . . . . . . . . . . . . .180
58786 . . . . . . . . . . . . . . . . .173
58787 . . . . . . . . . . . . . . . . .180
58789 . . . . . . . . . . . . . . . . .180
58792 . . . . . . . . . . . . . . . . .180
58794 . . . . . . . . . . . . . . . . .180
58795 . . . . . . . . . . . . . . . . .180
58813 . . . . . . . . . . . . . . . . .180
58815 . . . . . . . . . . . . . . . . .181
58816 . . . . . . . . . . . . . . . . .180
58819 . . . . . . . . . . . . . . . . .180
58821 . . . . . . . . . . . . . . . . .181
58831 . . . . . . . . . . . . . . . . .172
58860 . . . . . . . . . . . . . . . . .177
58862 . . . . . . . . . . . . . . . . .177
58936 . . . . . . . . . . . . . . . . .177
58937 . . . . . . . . . . . . . . . . .176
58939 . . . . . . . . . . . . . . . . .175
58941 . . . . . . . . . . . . . . . . .176
58942 . . . . . . . . . . . . . . . . .177
59803 . . . . . . . . . . . . . . . . .179
59822 . . . . . . . . . . . . . . . . .179
59841 . . . . . . . . . . . . . . . . .179
59850 . . . . . . . . . . . . . . . . .179
59859 . . . . . . . . . . . . . . . . .179
59860 . . . . . . . . . . . . . . . . .179
59864 . . . . . . . . . . . . . . . . .179
59867 . . . . . . . . . . . . . . . . .179
59870 . . . . . . . . . . . . . . . . .179
59934 . . . . . . . . . . . . . . . . .179
59936 . . . . . . . . . . . . . . . . .179
69000 . . . . . . . . . . . . . . . . .185
69127 . . . . . . . . . . . . . . . . .215
69162 . . . . . . . . . . . . . . . . .215
69164 . . . . . . . . . . . . . . . . .215
69165 . . . . . . . . . . . . . . . . .215
69166 . . . . . . . . . . . . . . . . .212
69167 . . . . . . . . . . . . . . . . .194
69168 . . . . . . . . . . . . . . . . .207
69169 . . . . . . . . . . . . . . . . .215
69171 . . . . . . . . . . . . . . . . .211
69172 . . . . . . . . . . . . . . . . .213
69174 . . . . . . . . . . . . . . . . .214
69175 . . . . . . . . . . . . . . . . .209
69176 . . . . . . . . . . . . . . . . .209
69177 . . . . . . . . . . . . . . . . .209
69179 . . . . . . . . . . . . . . . . .211
69180 . . . . . . . . . . . . . . . . .210
69181 . . . . . . . . . . . . . . . . .211
69182 . . . . . . . . . . . . . . . . .205
69183 . . . . . . . . . . . . . . . . .193
69184 . . . . . . . . . . . . . . . . .194
69185 . . . . . . . . . . . . . . . . .211
69186 . . . . . . . . . . . . . . . . .193
69189 . . . . . . . . . . . . . . . . .213
69190 . . . . . . . . . . . . . . . . .192
69191 . . . . . . . . . . . . . . . . .191
Product Number Page
69195 . . . . . . . . . . . . . . . . .210
69197 . . . . . . . . . . . . . . . . .191
69198 . . . . . . . . . . . . . . . . .205
69199 . . . . . . . . . . . . . . . . .213
69200 . . . . . . . . . . . . . . . . .210
69205 . . . . . . . . . . . . . . . . .208
69206 . . . . . . . . . . . . . . . . .209
69208 . . . . . . . . . . . . . . . . .209
69213 . . . . . . . . . . . . . . . . .204
69214 . . . . . . . . . . . . . . . . .204
69215 . . . . . . . . . . . . . . . . .204
69217 . . . . . . . . . . . . . . . . .204
69221 . . . . . . . . . . . . . . . . .206
69222 . . . . . . . . . . . . . . . . .205
69223 . . . . . . . . . . . . . . . . .206
69224 . . . . . . . . . . . . . . . . .206
69225 . . . . . . . . . . . . . . . . .206
69226 . . . . . . . . . . . . . . . . .208
69228 . . . . . . . . . . . . . . . . .208
69231 . . . . . . . . . . . . . . . . .191
69232 . . . . . . . . . . . . . . . . .191
69233 . . . . . . . . . . . . . . . . .191
69234 . . . . . . . . . . . . . . . . .192
69235 . . . . . . . . . . . . . . . . .192
69236 . . . . . . . . . . . . . . . . .193
69237 . . . . . . . . . . . . . . . . .193
69238 . . . . . . . . . . . . . . . . .192
69239 . . . . . . . . . . . . . . . . .194
69241 . . . . . . . . . . . . . . . . .194
69242 . . . . . . . . . . . . . . . . .195
69243 . . . . . . . . . . . . . . . . .195
69244 . . . . . . . . . . . . . . . . .195
69245 . . . . . . . . . . . . . . . . .195
69246 . . . . . . . . . . . . . . . . .208
69247 . . . . . . . . . . . . . . . . .198
69248 . . . . . . . . . . . . . . . . .199
69249 . . . . . . . . . . . . . . . . .199
69250 . . . . . . . . . . . . . . . . .199
69251 . . . . . . . . . . . . . . . . .199
69252 . . . . . . . . . . . . . . . . .199
69253 . . . . . . . . . . . . . . . . .200
69254 . . . . . . . . . . . . . . . . .200
69256 . . . . . . . . . . . . . . . . .198
69257 . . . . . . . . . . . . . . . . .196
69258 . . . . . . . . . . . . . . . . .198
69260 . . . . . . . . . . . . . . . . .196
69261 . . . . . . . . . . . . . . . . .196
69263 . . . . . . . . . . . . . . . . .196
69264 . . . . . . . . . . . . . . . . .196
69265 . . . . . . . . . . . . . . . . .197
69266 . . . . . . . . . . . . . . . . .197
69267 . . . . . . . . . . . . . . . . .197
69268 . . . . . . . . . . . . . . . . .197
69269 . . . . . . . . . . . . . . . . .197
69270 . . . . . . . . . . . . . . . . .198
69273 . . . . . . . . . . . . . . . . .210
69284 . . . . . . . . . . . . . . . . .216
69287 . . . . . . . . . . . . . . . . .212
69288 . . . . . . . . . . . . . . . . .213
69289 . . . . . . . . . . . . . . . . .214
69292 . . . . . . . . . . . . . . . . .212
69294 . . . . . . . . . . . . . . . . .200
69295 . . . . . . . . . . . . . . . . .202
69296 . . . . . . . . . . . . . . . . .200
69297 . . . . . . . . . . . . . . . . .203
69298 . . . . . . . . . . . . . . . . .202
P
H
O
T
O
O
P
T
I
C
I
N
D
E
X
For more complete product information visit www.sylvania.com Symbols/Footnotes on page 221-224
238
P
H
O
T
O
O
P
T
I
C
I
N
D
E
X
Index by Product
Number (cont.)
Product Number Page
69299 . . . . . . . . . . . . . . . . .214
69301 . . . . . . . . . . . . . . . . .203
69303 . . . . . . . . . . . . . . . . .212
69306 . . . . . . . . . . . . . . . . .212
69310 . . . . . . . . . . . . . . . . .198
69311 . . . . . . . . . . . . . . . . .205
69315 . . . . . . . . . . . . . . . . .201
69316 . . . . . . . . . . . . . . . . .207
69319 . . . . . . . . . . . . . . . . .211
69320 . . . . . . . . . . . . . . . . .190
69327 . . . . . . . . . . . . . . . . .190
69336 . . . . . . . . . . . . . . . . .201
69338 . . . . . . . . . . . . . . . . .216
69339 . . . . . . . . . . . . . . . . .202
69340 . . . . . . . . . . . . . . . . .202
69342 . . . . . . . . . . . . . . . . .203
69343 . . . . . . . . . . . . . . . . .208
69344 . . . . . . . . . . . . . . . . .214
69347 . . . . . . . . . . . . . . . . .210
69349 . . . . . . . . . . . . . . . . .216
69350 . . . . . . . . . . . . . . . . .200
69351 . . . . . . . . . . . . . . . . .203
69352 . . . . . . . . . . . . . . . . .216
69359 . . . . . . . . . . . . . . . . .201
69360 . . . . . . . . . . . . . . . . .201
69364 . . . . . . . . . . . . . . . . .207
74440 . . . . . . . . . . . . . . . . .172
76302 . . . . . . . . . . . . . . . . .176
76304 . . . . . . . . . . . . . . . . .176
76305 . . . . . . . . . . . . . . . . .176
76311 . . . . . . . . . . . . . . . . .176
76313 . . . . . . . . . . . . . . . . .176
76314 . . . . . . . . . . . . . . . . .176
76317 . . . . . . . . . . . . . . . . .176
76319 . . . . . . . . . . . . . . . . .176
76321 . . . . . . . . . . . . . . . . .176
76362 . . . . . . . . . . . . . . . . .176
Index by ANSI Code
Type Page
BAA . . . . . . . . . . . . . . . . . . .172
BBA . . . . . . . . . . . . . . . . . . .172
BCK . . . . . . . . . . . . . . . . . . .172
BCM . . . . . . . . . . . . . . . . . .176
BHC/DYS/DYV . . . . . . . . . . .172
BHC/DYS/DYV/X . . . . . . . . .172
BHC/DYS/DYV-5 . . . . . . . . .172
BRJ/EVB . . . . . . . . . . . . . . .172
BRL . . . . . . . . . . . . . . . . . . .172
BRN . . . . . . . . . . . . . . . . . .172
BTL . . . . . . . . . . . . . . . . . . .176
BTM . . . . . . . . . . . . . . . . . .176
BTN . . . . . . . . . . . . . . . . . . .176
BTP . . . . . . . . . . . . . . . . . . .176
BTR . . . . . . . . . . . . . . . . . . .176
BVA . . . . . . . . . . . . . . . . . . .172
BVE . . . . . . . . . . . . . . . . . . .172
BVM . . . . . . . . . . . . . . . . . .176
BVT . . . . . . . . . . . . . . . . . . .176
BVV . . . . . . . . . . . . . . . . . . .176
BVW . . . . . . . . . . . . . . . . . .176
CAX . . . . . . . . . . . . . . . . . . .172
CBA . . . . . . . . . . . . . . . . . . .172
CXZ . . . . . . . . . . . . . . . . . . .176
CYV . . . . . . . . . . . . . . . . . . .176
CYX . . . . . . . . . . . . . . . . . . .176
DDK . . . . . . . . . . . . . . . . . .172
DDL . . . . . . . . . . . . . . . . . . .172
DDM . . . . . . . . . . . . . . . . . .172
DDS . . . . . . . . . . . . . . . . . .172
DED . . . . . . . . . . . . . . . . . . .172
DEK/DFW . . . . . . . . . . . . . .172
DNE . . . . . . . . . . . . . . . . . . .172
DNF . . . . . . . . . . . . . . . . . . .172
DNS/FMC . . . . . . . . . . . . . .176
DNT/FMD . . . . . . . . . . . . . .176
DPY . . . . . . . . . . . . . . . . . . .176
DTA . . . . . . . . . . . . . . . . . . .176
DTY . . . . . . . . . . . . . . . . . . .176
DVY . . . . . . . . . . . . . . . . . . .172
DWE . . . . . . . . . . . . . . . . . .176
DWT . . . . . . . . . . . . . . . . . .176
DXW . . . . . . . . . . . . . . . . . .176
DYH . . . . . . . . . . . . . . . . . .172
DZE . . . . . . . . . . . . . . . . . . .172
EBV . . . . . . . . . . . . . . . . . . .172
ECA . . . . . . . . . . . . . . . . . . .172
ECT . . . . . . . . . . . . . . . . . . .172
EFM . . . . . . . . . . . . . . . . . . .172
EFN . . . . . . . . . . . . . . . . . . .172
EFP . . . . . . . . . . . . . . . . . . .172
EFP/X . . . . . . . . . . . . . . . . .172
EFR . . . . . . . . . . . . . . . . . . .172
EFR-5/X . . . . . . . . . . . . . . . .172
EFX . . . . . . . . . . . . . . . . . . .176
EGE . . . . . . . . . . . . . . . . . . .176
EGG . . . . . . . . . . . . . . . . . . .176
EGJ . . . . . . . . . . . . . . . . . . .176
EGK . . . . . . . . . . . . . . . . . . .176
EGN . . . . . . . . . . . . . . . . . . .176
EGR . . . . . . . . . . . . . . . . . . .177
EGT . . . . . . . . . . . . . . . . . . .177
EGW . . . . . . . . . . . . . . . . . .177
EHA . . . . . . . . . . . . . . . . . . .172
EHC/EHB . . . . . . . . . . . . . . .177
ANSI Page
EHD . . . . . . . . . . . . . . . . . . .177
EHE . . . . . . . . . . . . . . . . . . .173
EHF . . . . . . . . . . . . . . . . . . .177
EHG . . . . . . . . . . . . . . . . . . .177
EHJ . . . . . . . . . . . . . . . . . . .173
EHP . . . . . . . . . . . . . . . . . . .177
EHR . . . . . . . . . . . . . . . . . . .177
EHZ . . . . . . . . . . . . . . . . . . .177
EJA . . . . . . . . . . . . . . . . . . .173
EJG . . . . . . . . . . . . . . . . . . .177
EJL . . . . . . . . . . . . . . . . . . .173
EJM . . . . . . . . . . . . . . . . . . .173
EJV . . . . . . . . . . . . . . . . . . .173
EKB . . . . . . . . . . . . . . . . . . .177
EKE . . . . . . . . . . . . . . . . . . .173
EKE/X . . . . . . . . . . . . . . . . .173
EKP/ENA . . . . . . . . . . . . . . .173
ELC . . . . . . . . . . . . . . . . . . .173
ELC-3/X . . . . . . . . . . . . . . . .173
ELC-7/X . . . . . . . . . . . . . . . .173
ELC-7/X . . . . . . . . . . . . . . . .173
ELC-HL . . . . . . . . . . . . . . . .173
ELD . . . . . . . . . . . . . . . . . . .173
ELH . . . . . . . . . . . . . . . . . . .173
ELS . . . . . . . . . . . . . . . . . . .173
ELV . . . . . . . . . . . . . . . . . . .173
ELZ . . . . . . . . . . . . . . . . . . .173
EMG . . . . . . . . . . . . . . . . . .173
EMM/EKS . . . . . . . . . . . . . .173
ENG . . . . . . . . . . . . . . . . . . .173
ENH . . . . . . . . . . . . . . . . . . .173
ENH-5 . . . . . . . . . . . . . . . . .173
ENL . . . . . . . . . . . . . . . . . . .173
ENX . . . . . . . . . . . . . . . . . . .173
ENX-5 . . . . . . . . . . . . . . . . .173
ENX-7 . . . . . . . . . . . . . . . . .173
EPR . . . . . . . . . . . . . . . . . . .173
EPS . . . . . . . . . . . . . . . . . . .173
EPS/230 . . . . . . . . . . . . . . .173
EPT . . . . . . . . . . . . . . . . . . .173
EPV . . . . . . . . . . . . . . . . . . .173
EPX . . . . . . . . . . . . . . . . . . .174
EPZ . . . . . . . . . . . . . . . . . . .174
ERK . . . . . . . . . . . . . . . . . . .174
ERM . . . . . . . . . . . . . . . . . .174
ESA/FHD . . . . . . . . . . . . . . .174
ESB . . . . . . . . . . . . . . . . . . .174
ETJ . . . . . . . . . . . . . . . . . . .174
EVA . . . . . . . . . . . . . . . . . . .174
EVC . . . . . . . . . . . . . . . . . . .174
EVD . . . . . . . . . . . . . . . . . . .174
EVV . . . . . . . . . . . . . . . . . . .180
EVW . . . . . . . . . . . . . . . . . .174
EWR . . . . . . . . . . . . . . . . . .180
EXC/230 . . . . . . . . . . . . . . .178
EXC/240 . . . . . . . . . . . . . . .178
EXD/230 . . . . . . . . . . . . . . .178
EXD/240 . . . . . . . . . . . . . . .178
EXE/230 . . . . . . . . . . . . . . .178
EXE/240 . . . . . . . . . . . . . . .179
EXG . . . . . . . . . . . . . . . . . . .179
EXL . . . . . . . . . . . . . . . . . . .180
EXM . . . . . . . . . . . . . . . . . .180
EXR . . . . . . . . . . . . . . . . . . .174
EXW . . . . . . . . . . . . . . . . . .174
EXY . . . . . . . . . . . . . . . . . . .174
ANSI Page
EXY . . . . . . . . . . . . . . . . . . .174
EYB . . . . . . . . . . . . . . . . . . .174
EYB-5 . . . . . . . . . . . . . . . . .174
EYB-7 . . . . . . . . . . . . . . . . .174
EZE . . . . . . . . . . . . . . . . . . .174
EZL . . . . . . . . . . . . . . . . . . .180
FAD . . . . . . . . . . . . . . . . . . .177
FAL . . . . . . . . . . . . . . . . . . .177
FBV . . . . . . . . . . . . . . . . . . .174
FCB . . . . . . . . . . . . . . . . . . .177
FCM . . . . . . . . . . . . . . . . . .177
FCR . . . . . . . . . . . . . . . . . . .174
FCS . . . . . . . . . . . . . . . . . . .174
FDA . . . . . . . . . . . . . . . . . . .177
FDB . . . . . . . . . . . . . . . . . . .177
FDN . . . . . . . . . . . . . . . . . . .177
FDS/DZE . . . . . . . . . . . . . . .174
FDT 64628 . . . . . . . . . . . . .174
FDV . . . . . . . . . . . . . . . . . . .174
FEL . . . . . . . . . . . . . . . . . . .177
FEP/220 . . . . . . . . . . . . . . .177
FEP/240 . . . . . . . . . . . . . . .177
FER . . . . . . . . . . . . . . . . . . .177
FEV . . . . . . . . . . . . . . . . . . .177
FEX/230 . . . . . . . . . . . . . . .177
FEX/240 . . . . . . . . . . . . . . .177
FEY . . . . . . . . . . . . . . . . . . .177
FFJ . . . . . . . . . . . . . . . . . . .177
FFM . . . . . . . . . . . . . . . . . . .177
FFN . . . . . . . . . . . . . . . . . . .179
FFP . . . . . . . . . . . . . . . . . . .179
FFR . . . . . . . . . . . . . . . . . . .179
FFS . . . . . . . . . . . . . . . . . . .179
FFT . . . . . . . . . . . . . . . . . . .177
FHM . . . . . . . . . . . . . . . . . .177
FHS . . . . . . . . . . . . . . . . . . .174
FKT/EYH . . . . . . . . . . . . . . .174
FKW . . . . . . . . . . . . . . . . . .177
FLE . . . . . . . . . . . . . . . . . . .174
FLK . . . . . . . . . . . . . . . . . . .177
FLT . . . . . . . . . . . . . . . . . . .174
FMR . . . . . . . . . . . . . . . . . .177
FNS . . . . . . . . . . . . . . . . . . .174
FNT . . . . . . . . . . . . . . .174, 175
FRG . . . . . . . . . . . . . . . . . . .177
FRK . . . . . . . . . . . . . . . . . . .177
FRN . . . . . . . . . . . . . . . . . . .179
FSG . . . . . . . . . . . . . . . . . . .175
FSH . . . . . . . . . . . . . . . . . . .177
FSX . . . . . . . . . . . . . . . . . . .175
FSY . . . . . . . . . . . . . . . . . . .175
FTK . . . . . . . . . . . . . . . . . . .177
FVL . . . . . . . . . . . . . . . . . . .177
FVM . . . . . . . . . . . . . . . . . .177
FXL . . . . . . . . . . . . . . . . . . .175
FXL-HL . . . . . . . . . . . . . . . .175
GCA . . . . . . . . . . . . . . . . . . .177
GCB . . . . . . . . . . . . . . . . . . .175
GCC . . . . . . . . . . . . . . . . . . .175
GCD . . . . . . . . . . . . . . . . . .175
GKV . . . . . . . . . . . . . . . . . . .178
GLA . . . . . . . . . . . . . . . . . . .178
GLC . . . . . . . . . . . . . . . . . . .178
GLF . . . . . . . . . . . . . . . . . . .178
O
S
R
A
M
P
L
A
N
O
N
For more complete product information visit www.sylvania.com 239
OSRAM PLANON®
New Fluorescent Technology
The OSRAM PLANON®is a two-dimensional, mercury-free light
source based on the operating principle of excimer discharge.
OSRAM technology sets standards
Mercury-free light tile
The luminous body of OSRAM PLANON®can be
compared with a tile. Thanks to its specific shape
and unique uniform light output, PLANON®opens
new construction and application possibilities for
the lighting industry.
Unique advantages
The new mercury-free discharge light source OSRAM PLANON®
has a number of unique product characteristics:
Unique lighting power
• wide viewing and illumination angle
• uniform high luminance from center to edge
• diagonal lengths from 10.4" to 21.3"
• ultra flat at <10mm (0.4")
Extremely long lamp life, up to 100,000 hours
• absence of failure-prone electrodes
• no bulb darkening
Extremely thin 10mm
Mercury-free
• luminous flux not related to temperature
- same light output from -30°C to +85°C ambients
• instant light with high luminance
Lamp and ballast available as system
Applications
• LCD backlighting • Signage backlighting
• Architectural effects • Film and photography lighting
• Digital imaging • Information displays
• Indoors or outdoors • Task lighting
OSRAM OPTO SEMICONDUCTORS
THE LEADER IN LED GENERAL LIGHTING SOLUTIONS
Innovative light-emitting diodes are compound semiconductors that convert electric current directly to light. Just a few
millimeters in size, LEDs offer distinct advantages through advanced technology, making them a real alternative
to conventional lamps in many applications.
TECHNOLOGICAL ADVANTAGES
Low power consumption and heat generation
Extremely long life
Negligible early failures
High color efficiency
Small dimensions
High resistance to shock and vibration
Directed radiation
No IR/UV radiation -Optimized power supplies and controls
USER BENEFITS
•Creative design possibilities for innovative light solutions through a variety of LED colors, compactness and flexible modularization
Economically attractive because of low power consumption, long life and minimal maintenance
Maximized safety due to excellent reliability, even in difficult operating conditions
CREATIVE LIGHT SOLUTIONS FOR ALL KINDS OF APPLICATIONS
LED modules and power supplies from OSRAM Opto Semiconductors are the ideal basis for creative design-ins and new light solutions in
a wide range of applications:
Colored light of your choice - LEDs emit yellow, orange, red, blue, green and white light, 3 color multi - LED (RGB) option are
available
Colored light with plexiglass optics for highly decorative effects
Can be adapted to complex structures - e.g. backlighting of letters - through compact, flexible modules
Extremely low-profile light solutions
Reliable orientation lighting that is easy to install and integrates perfectly in the existing architecture with minimal structural change
Economical operation through low power consumption
Reliable outdoor operation through mechanical ruggedness in a wide range of operating temperatures
Ideal for powering by solar energy through minimum consumption and low forward voltage
VERTICALLY INTEGRATED
OSRAM Opto Semiconductors offers the core competencies needed for LED lamp module and power supply production - from discrete
components through electrical, thermal and optical design to complex modules and electronic controls.
CONNECTORS
Please call 1-800-LIGHTBULB for assistance.
COMPLETE SYSTEMS ENGINEERING
Our solutions come complete with matching power supplies, dimming and RGB controls. Dimmers are compatible with industry standard
protocols such as 0-10 V and DMX 512 (with DMX to 0-10V converters).
COMPLETE LIGHT SOURCE SOLUTION
Combined with OSRAM SYLVANIA, OSRAM Opto Semiconductors offers the full spectrum of lighting solutions for any project.
Standards and regulations
In the case of LEDs and LED modules, there are regulations for protection of the human eye against excessive doses of radiation. These
are based on the tolerances issued by the ICNRP. OSRAM Opto Semiconductors can submit certification by an accredited test laboratory
for all standard modules. LED lamp modules and power supplies by OSRAM are UL recognized and listed in the Sign Accessories Manual
(SAM).
The stipulations of the low voltage directive are not applicable to LED modules because of their operating voltage of 10 or 24 V DC.
LED modules do not produce any interference in the context of EMC.
The major directives for eye safety:
1. IEC 60825-1 A2: Safety of Laser Devices
2. ANSI IESNA RP - 27.1 to 27.3
3. ACGIH (American Conference of Governmental Industrial Hygienists)
4. CIE TC 6-47 Photobiological Safety of Lamps and LampSystems
For more complete product information visit www.sylvania.com
240
L
E
D
S
Y
S
T
E
M
S
L
E
D
S
Y
S
T
E
M
S
TRULY ILLUMINATING:
LED MODULES FROM OSRAM OS
LED modules from OSRAM Opto Semiconductors consist of a certain number of LEDs with integrated passive or active
current regulation. The single LEDs are mounted on either rigid or flexible printed circuit boards. Secondary optical
elements such as lenses, reflectors and surface light guides can be added for enhanced performance.
POSSIBILITIES TODAY AND TOMORROW
OSRAM Opto Semiconductors produces a high-performance selection of fully contained LED modules - power-saving and cost-saving - for a
wide range of conventional and emerging uses in general lighting.
THREE FAMILIES - VERSATILE AND FLEXIBLE
LED modules without a lens system
- LINEARlight (Rigid or flexible; Monochromatic or integrated RGB)
- BACKlight
- COINlight
LED modules with a lens system
- EFFECTlight
LED modules with light guides
- MARKERlight (rectangular, square, round)
- LEDtag
LED MODULES ACCESSORIES
- Optics, dimming
ELECTRICAL DESIGN OF MODULES
In electrical terms, LEDs are semiconductor diodes. Their major electrical characteristics are:
- Forward voltage VF
- Forward current IF
To ensure long life, the specified forward current should not be exceeded. Modules from OSRAM OS exhibit the following features:
- Series connection of LEDs
- Combined with passive and active current limiting
- Current control device (BCR) are built in for all the OSRAM LED lamp modules
- Operation on 10 V DC and 24 V DC
- Easy operation with OPTOTRONIC®power supplies
THE RIGHT CONNECTION -
OSRAM LED SYSTEMS FOR LIGHTING
OSRAM Opto Semiconductors offers you more than first-class LEDs and LED modules. You no longer have to spend your
time looking for any extra components you need. Instead you can focus on what is essential for you: your
product and your business. In addition to LED modules we deliver optimized power supplies,
dimming and RGB controls, and other accessories (pg. 264 & 265). For the latest information
call 1-800-LIGHTBULB.
OPTOTRONIC POWER SUPPLY
•Electronically stabilized, load-insensitive DC output voltage
Shortcircuit-proof and overload protected
Designed and built to all applicable standards
For power supply and packages, please refer to page 265
Long Life
Low ripple voltage
For more complete product information visit www.sylvania.com 241
OSRAM OPTO SEMICONDUCTORS:
LED TECHNOLOGY IS THE FUTURE
HOW DOES AN LED WORK?
A light-emitting diode consists of several layers of semicon-
ductor material. When the diode is forward biased, light is
generated in a thin layer, the so-called active layer. Unlike
incandescent lamps, which radiate a continuous spectrum, an
LED emits an almost monochromatic light of a particular color.
The color of the light depends on the material used. Two mate-
rial systems - AlInGaP and InGaN - are used for creating high
brightness LEDs in all colors from red to blue and also in white
using phosphors.
The efficiency of LEDs has very much improved in the last few
years, and has already reached levels of 30lm/W and more -
depending on the color. This is the result of high-quality pro-
duction and advanced technologies.
LED PACKAGES
The typical size of an LED is approximately a few hundred micrometers. The semiconductor is mounted in a package for easy electrical
contact and environmental protection. There are two basic types of packages:
THT (through-hole technology)
This kind of package is soldered "through holes" to the circuit board. The most common type is the radial 5 mm
package. The LED chip is seated in the reflector, which is connected to the cathode lead. A bond wire establish-
es electrical contact to the anode. The light is emitted by a lens integrated into the package. Different radiation
characteristics are produced as a function of chip-to-lens spacing and the shape of the lens.
SMT (surface-mount technology)
This modern design consists of a plastic package that also serves as the reflector. The LED chip is seated in the
cavity. This cavity is filled with epoxy resin to improve light output and protect the chip against environmental
influences. SMT components can be assembled faster and with better quality than THT components.
ELECTRICAL DATA
The highest luminosity is produced with a DC voltage source. The necessary forward voltage depends on the color of the LED light, vary-
ing between 2 and 4 V at forward currents up to 70mA.
TEMPERATURE RESPONSE
The optical output power drops as temperature increases. Temperature dependence is more significant in yellow LEDs than in green
ones. This drop in power, as a function of temperature, can be reversed and has nothing to do with degradation. The maximum operat-
ing temperature for LEDs is normally 100 °C, and this should not be exceeded.
LIFETIME AND DEGRADATION
Just like a conventional source of light, the intensity of LED light gradually diminishes in the course of continuous operation. When an
LED produces 50% of its original luminous efficiency, it has, by definition, reached the end of its life.
Under reasonable operating conditions LEDs can last up to 100,000 hours.
WHITE LIGHT LEDs
To generate white light, the radiation of a blue diode is used to stimulate a secondary (fluorescent) emission from a properly chosen
phosphor. By setting the appropriate concentration of luminescent material, the blue primary light from the diode combined with the yel-
low light emitted by the phosphor creates a spectral wavelength distribution that is perceived as white by the human eye. The color ren-
dering index thus achieved is approximately 80.
For more complete product information visit www.sylvania.com
242
L
E
D
S
Y
S
T
E
M
S
LED chip bond wire
active layer
substrate
conductive glue
L
E
D
S
Y
S
T
E
M
S
The following item was accepted into the 2003 IESNA Progress Report which recognizes innovative products
introduced to the industry during that year.
LINEARlight Color Mix
HOW TO READ PRODUCT INFORMATION - LED lamp modules
Operating Voltage (V) DC voltage applied to the entire module.
Wavelength (nm) / The center wavelength of the light emitted by the LED expressed in nm OR the CIE X and Y color coordinates for white light sources.
Color Coordinates
Inter-LED Spacing (mm) Space between individual LEDs mounted on the module.
Luminance (mlm) or When reported in mlm, this is the total amount of light leaving the module, also known as luminous flux. When reported in cd/m2, this is the
(cd/m2)brightness of the LED module when viewing it. The cd/m2value applies only to MARKERlight products.
Luminous Intensity (cd) Intensity of the light shining out from the module. This value is especially important on EFFECTlights.
Viewing Angle (°) 2 times the angle between the peak intensity at the center of the beam and the 50% intensity direction.
Maximum Board Applies only to BACKlights. This is the maximum separation between two consecutive boards in a BACKlight module.
Spacing (mm)
Luminous Area (mm2)Applies only to MARKERlights. This is the area that actually appears lit when looking towards the module.
Weight & Measurement
For weight and measurement information, please visit www.sylvania.com.
For more complete product information visit www.sylvania.com 243
70010
LINEAR/OS/LM01A/W
10
3.2
White
32
-30 to +65
448 x 10 x 3.5
14
29
0.3
120
70027
ML/82X33/OS/ML01B/B
10
1.2
Blue
470
12
-30 to +65
112.3 x 48 x 7
79.5 x 3
Product Number
Ordering Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm) Color Coordinates
LEDs/Module
Operating Temperature (˚C)
Dimensions (mm)
Inter-LED Spacing (mm)
Luminous Flux (|m)
Luminous Intensity (cd)
Viewing Angle (˚)
Maximum Board Spacing (mm)
Luminous Area (mm2)
70011
BACKLIGHT/615/OS/LM03A/A
10
4
Amber Red
617
32
-30 to +65
559 x 30 x 6
15
54
0.535
120
70017
FXLIGHT/505/OS/WL01A/V
24
1.3
Verde
503
10
-30 to +65
70 x 28 x 34.5
2000
4
OPTOTRONIC®LED Power Supplies
OSRAM OPROTRONIC power supplies are compact and electronically stabilized. The wide range of input voltage from 100
to 240 V A.C. enables worldwide use on single-phase A.C. power lines. These supplies are available in 10 V d.c. and 24 V d.c.
outputs. The OPTORONIC power supplies are protected against open circuit, short circuit, and overload and overheating.
They are UL recognized and FCC compliant.
KEY SYSTEM FEATURE
New, small enclosure size (OT6, OT20, OT25 fit into Weather resistant housing
small junction box) Long life
•Lightweight, low profile Short circuit and overload protection
-20˚C through 50˚C operation Low power supply losses
•Wide input voltage range Remote mounting possible
Isolated output OT50 model rated for outdoor, damp location
UL Class 2 output
OT RGB controls are ideal for Colormixing or Color sequencing applications
Pulse width modulation (PWM) dimming
Dimming range of 0-100% with OTDIM & OT RGB 3CH DIM
Item Number 51500 OT 6/ 100-240/ 10 COS Circular Opto Semi-conductors; S: Square
OPTOTRONIC Output Voltage (DC)
Output Wattage (6 Watts) Input Voltage (AC)
Item
Number Description For LED Lamp Modules Family
51500 OT6/100-240/10COS LINEARlight, BACKlight, MARKERlight (Rectangular),and LINEARlight FLEX SIDELED
51505 OT25/120/10 LINEARlight, BACKlight, MARKERlight (Rectangular),and LINEARlight FLEX SIDELED
51508 OT50/120/10 LINEARlight, BACKlight, MARKERlight (Rectangular),and LINEARlight FLEX SIDELED
51501 OT6/100-240/24COS MARKERlight (Square & Circular), EFFECTlight, COINlight TOPLED, COINlight SIDELED
and LINEARlight - FLEX TOPLED
LINEARlight Colormix RGB and LINEARlight Flex TOP Colormix RGB
51512 OT20/120-240/24S MARKERlight (Square & Circular), EFFECTlight, COINlight TOPLED, COINlight SIDELED
and LINEARlight - FLEX TOPLED
LINEARlight Colormix RGB and LINEARlight Flex TOP Colormix RGB
System Life / Warranty
OPTOTRONIC LED Power Supply Products are covered by our LED System Warranty, a comprehensive light source, and power supply system
warranty. For additional detail, refer to our latest version of the LED System Warranty bulletin found in the warranty section of this catalog.
OSRAM LED Lamp Modules Accessories
LINEARlight OPTICS OP4x1-20
LINEARlight Optics is a supplementary optical lens for the LINEARlight module. The optical effect of the optics is a reduction of the viewing
angle from 120˚ to 20˚ and / or 25˚ and proportional intensification of the light. The optic provides light intensification and mechanical protec-
tion of the LED module. The optic is suitable for all LED colors.
Each modules lens optic is 56mm long and covers 4 LEDs, which is the smallest divisible unit of LINEARlight. Eight optics are needed to cover
the full length of a LINEARlight strip. The guide pin feature ensures precise alignment that can be easily snapped into place.
For more complete product information visit www.sylvania.com
244
L
E
D
S
Y
S
T
E
M
S
70006
LINEAR/587/OS/LM01A/Y1
10
4.00
Yellow
587
32
-30 to +65
448 X 10 X 3.5
14.000
69
0.72
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70008
LINEAR/525/OS/LM01A/T1
10
4.00
True Green
525
32
-30 to +65
448 x 10 x 3.5
14.000
36
0.38
120
70083
LINEAR/610/OS/LM01A
10
4.00
Orange
606
32
-30 to +65
448 X 10 X 3.5
14.000
86
0.90
120
70007
LINEAR/615/OS/LM01A/A
10
4.00
Amber Red
617
32
-30 to +65
448 X 10 X 3.5
14.000
54
0.56
120
LINEARLIGHT – RIGID
For more complete product information visit www.sylvania.com 245
L
E
D
S
Y
S
T
E
M
S
For more complete product information visit www.sylvania.com
246
L
E
D
S
Y
S
T
E
M
S
70009
LINEAR/470/OS/LM01A/B1
10
4.00
Blue
470
32
-30 to +65
448 x 10 x 3.5
14.000
9
0.09
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
Color Temp (K)
LEDs/Module
Operating Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70044
LINEAR/633/OS/LM1A/S1
10
4
Super Red
633
32
-30 to +65
448 X 10 X 3.5
14.000
54
0.56
120
70010
LINEAR/OS/LM01A/W1
10
3.20
White
5400K, 4700K
32
-30 to +65
448 X 10 X 3.5
14.000
29
0.30
120
LINEARLIGHT – RIGID
70046
COIN/615/OS/CM01B/A
24
0.50
Amber Red
615
8
-30 to +65
33 X 5.5 X 11
45
3
135
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (degrees)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70048
COIN/525/OS/CM01B/T
24
0.90
True Green
528
8
-30 to +65
33 X 5.5 X 11
3
0.135
120
70050
COIN/OS/CM01B/W
24
0.90
White
X=0.32; Y=0.31
8
-30 to +65
33 X 5.5 X 11
5
0.195
120
70049
COIN/470/OS/CM01B/B
24
0.90
Blue
470
8
-30 to +65
33 X 5.5 X 11
1
0.04
120
70047
COIN/587/OS/CM01B/Y
24
0.50
Yellow
587
8
-30 to +65
33 X 5.5 X 11
2
0.105
120
COINLIGHT – SIDELED – 8 LEDS
For more complete product information visit www.sylvania.com 247
L
E
D
S
Y
S
T
E
M
S
70051
COIN/587/OS/CM01C/Y
24
1.50
Yellow
587
12
-30 to +65
33 X 5.5 X 11
3.6
0.105
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70053
COIN/525/OS/CM01C/T
24
1.30
True Green
525
12
-30 to +65
33 X 5.5 X 11
3.7
0.135
120
70055
COIN/OS/CM01C/W
24
1.30
White
X=0.32; Y=0.31
12
-30 to +65
33 X 5.5 X 11
6.5
0.195
120
70054
COIN/470/OS/CM01C/B
24
1.30
Blue
470
12
-30 to +65
33 X 5.5 X 11
1.4
0.04
120
70052
COIN/615/OS/CM01C/A
24
1.50
Amber Red
615
12
-30 to +65
33 X 5.5 X 11
4.3
0.135
120
COINLIGHT – SIDELED – 12 LEDS
For more complete product information visit www.sylvania.com
248
L
E
D
S
Y
S
T
E
M
S
70056
COIN/OS/CM01E/W1
24
1.20
White
X=0.32; Y=0.31
9
-30 to +55
33 X 3.5 X 9
10
0.37
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70058
COIN/587/OS/CM01E/Y1
24
1.2
Yellow
587
9
- 30 to +55
33 X 3.5 X 9
19
0.70
120
70060
COIN/470/OS/CM01E/B1
24
1.20
Blue
470
9
-30 to +55
33 X 3.5 X 9
3
0.11
120
70059
COIN/525/OS/CM01E/T1
24
1.20
True Green
525
9
-30 to +55
33 X 3.5 X 9
10
0.37
120
70057
COIN/617/OS/CM01E/A1
24
1.2
Amber Red
617
9
-30 to +55
33 X 3.5 X 9
24
0.89
120
COINLIGHT – TOPLED
For more complete product information visit www.sylvania.com 249
L
E
D
S
Y
S
T
E
M
S
70061
LINEARFLEXTOP/587/OS
/LM10A/Y1
24
72.0
Yellow
587
600
-30 to +65
8400 X 10 X 2.5
14.000
1290
0.72
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
Color Temp (K)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70063
LINEARFLEXTOP/525/OS
/LM10A/T1
24
72.0
True Green
525
600
-30 to +65
8400 X 10 X 2.5
14.000
675
0.38
120
70065
LINEARFLEXTOP/OS
/LM10A/W1
24
57.6
White
5400K, 4700K
600
-30 to +65
8400 X 10 X 2.5
14.000
540
0.30
120
70064
LINEARFLEXTOP/470/OS
/LM10A/B1
24
72.0
Blue
469
600
-30 to +65
8400 X 10 X 2.5
14.000
170
0.09
120
70062
LINEARFLEXTOP/617/OS
/LM10A/A
24
72.0
Amber Red
617
600
-30 to +65
8400 X 10 X 2.5
14.000
930
0.53
120
LINEARLIGHT – FLEXIBLE – TOPLED
For more complete product information visit www.sylvania.com
250
L
E
D
S
Y
S
T
E
M
S
70066
LINEARFLEXSIDE/615
/OS/LM11A/A
10
15.0
Amber Red
615
300
-30 to +65
4200X10X4.5
14.000
117
0.135
120
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
Color Temp (K)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
70068
LINEARFLEXSIDE/525
/OS/LM11A/T
10
30.0
True Green
528
300
-30 to +65
4200X10X4.5
14.000
147
0.16
120
70070
LINEARFLEXSIDE
/OS/LM11A/W1
10
30.0
White
5400K, 4700K
300
-30 to +65
4200X10X4.5
14.000
405
0.45
120
70069
LINEARFLEXSIDE/470
/OS/LM11A/B
10
30.0
Blue
470
300
-30 to +65
4200X10X4.5
14.000
37
0.04
120
70067
LINEARFLEXSIDE/587
/OS/LM11A/Y1
10
22.5
Yellow
587
300
-30 to +65
4200X10X4.5
14.000
405
0.45
120
LINEARLIGHT – FLEXIBLE – SIDELED
For more complete product information visit www.sylvania.com 251
L
E
D
S
Y
S
T
E
M
S
For more complete product information visit www.sylvania.com
252
L
E
D
S
Y
S
T
E
M
S
70072
LINEARLT OPTICS OS-OP4X1-20
-30 to +65
0.7 - 6.0
20 (except 25˚ for white)
Product Number
Ordering Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating Temperature (°C)
Dimensions (mm)
Inter-LED Spacing (mm)
Luminous Flux (lm)
Luminous Intensity (cd)
Viewing Angle (°)
Maximum Board Spacing (mm)
OPTICS ACCESSORIES
70073
LEDTag/633/OS-ML90A-S
9
0.18
Super Red
633
4
-30 to+45
71.5 X 38.5 X 14
185
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (mm)
Luminance (cd/m2)
Luminous
Intensity (cd)
Viewing Angle (°)
Maximum Board
Spacing (mm)
70075
LEDTag/528/OS-ML90A-T
9
0.36
True Green
528
4
-10 to +45
71.5 X 38.5 X 14
290
70077
LEDTAG/OS-ML90A-W
9
0.36
White
X=0.32; Y=0.31
4
-10 to +45
71.5 X 38.5 X 14
420
70076
LEDTag/470/OS-ML90A-B
9
0.36
Blue
470
4
-10 to +45
71.5 X 38.5 X 14
85
70074
LEDTag/606/OS-ML90A-O
9
0.18
Orange
606
4
-10 to +45
71.5 X 38.5 X 14
420
LED TAG
For more complete product information visit www.sylvania.com 253
L
E
D
S
Y
S
T
E
M
S
70080
LINEARCOLORMIX/OS
/LM01M/RGB
24
8.3
All colors
---
30
-30…+65
450 x 12 x 4
15
91
1.0
120
Product Number
Ordering
Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED Spacing
(mm)
Luminous Flux (lm)
Luminous Intensity
(cd)
Viewing Angle (°)
24
3.6
Green
525
30
-30…+65
51
0.57
120
24
2.9
Blue
467 for -B7; 473 for -B8
30
-30…+65
8
0.09
120
24
1.8
Red
617
30
-30…+65
32
0.36
120
LINEARLIGHT COLORMIX
For more complete product information visit www.sylvania.com
254
L
E
D
S
Y
S
T
E
M
S
70082
LINEARFLEXTOPCOLORMIX
/OS/LM10M/RGB
24
77.5
All colors
---
280
-30…+65
4200 x 11.5 x 2.5
15
849
1.0
120
Product Number
Ordering
Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (°C)
Dimensions (mm)
Inter-LED
Spacing (mm)
Luminous Flux (lm)
Luminous
Intensity (cd)
Viewing Angle (°)
24
33.6
Green
525
280
-30…+65
476
0.57
120
24
27.1
Blue
467, 473
280
-30…+65
75
0.09
120
24
16.8
Red
617
280
-30…+65
299
0.36
120
LINEARLIGHT FLEX TOP COLORMIX
For more complete product information visit www.sylvania.com 255
L
E
D
S
Y
S
T
E
M
S
For more complete product information visit www.sylvania.com
256
L
E
D
S
Y
S
T
E
M
S
70011
BACKLITE/615/OS/LM03A/A
10
4.00
Amber Red
617
32
-30 to +65
559 x 30 x 6
15.000
54
0.535
120
Product Number
Ordering Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating Temperature (°C)
Dimensions
Inter-LED Spacing
Luminous Flux (lm)
Luminous Intensity (cd)
Viewing Angle (°)
70013
BACKLITE/525/OS/LM03A/T1
10
4.00
True Green
525
32
-30 to +65
559 x 30 x 6
15.000
36
0.38
120
70012
BACKLITE/587/OS/LM03A/Y1
10
4.0
Yellow
587
32
-30 to +65
559 X 30 X 6
15.000
69
0.72
120
BACKLIGHT
70014
BACKLITE/470/OS/LM03A/B
10
4.00
Blue
470
32
-30 to +65
559 X 30 X 6
15.000
9
0.09
120
Product Number
Ordering Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm)
Color Temp (K)
LEDs/Module
Operating
Temperature (°C)
Dimensions
Inter-LED Spacing
Luminous Flux (lm)
Luminous Intensity(cd)
Viewing Angle (°)
70071
BACKLITE/610/OS/LM03B/O
10
4.0
Orange
606
32
-30 to +65
559X30X6
15.000
86
0.90
120
70081
BACKLITE/633/OS/LM03A/S
10
4.0
Super Red
633
32
-30 to +65
559x30x6
15.000
54
0.535
120
70045
BACKLITE/OS/LM03A/W1
10
3.20
White
6500K, 5400K
32
-30 to +65
559x30x6
15.000
29
0.30
120
BACKLIGHT
For more complete product information visit www.sylvania.com 257
L
E
D
S
Y
S
T
E
M
S
70015
FXLITE/615/OS/WL01A/A1
24
1.1
Amber Red
617
10
-30 to +65
70 x 28 x 34.5
3500
4
Product Number
Ordering Abbreviation
Operating Voltage (V)
Power (W)
Color
Wavelength (nm)
LEDs/Module
Operating
Temperature (° C)
Dimensions (mm)
Luminous
Intensity (cd)
Viewing Angle (°)
70017
FXLITE/505/OS/WL01A/V1
24
1.3
Verde
503
10
-30 to +65
70 x 28 x 34.5
2000
4
70018
FXLITE/470/OS/WL01A/B1
24
1.3
Blue
469
10
-30 to +65
70 x 28 x 34.5
350
4
70016
FXLITE/587/OS/WL01A/Y1
24
1.1
Yellow
587
10
-30 to +65
70 x 28 x 34.5
2500
4
EFFECTLIGHT
For more complete product information visit www.sylvania.com
258
L
E
D
S
Y
S
T
E
M
S
70039
ML/80D/615/OS/ML03A/A
24
1.92
Amber Red
615
40
-30 to +65
110 x 110 x 7
705
77
Product Number
Ordering Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm) /
Color Coordinates
LEDs/Module
Operating
Temperature (deg C)
Dimensions (mm)
Luminance (cd/m2)
Luminous Area
(diameter, mm)
70041
ML/80D/525/OS/ML03A/T
24
3.84
True Green
528
40
-30 to +65
110 x 110 x 7
705
77
70043
ML/80D/OS/ML03A/W1
24
3.84
White
X=0.32 Y=0.31
40
-30 to +65
110 x 110 x 7
2050
77
70042
ML/80D/470/OS/ML03A/B
24
3.84
Blue
470
40
-30 to +65
110 x 110 x 7
205
77
70040
ML/80D/587/OS/ML03A/Y1
24
2.88
Yellow
587
40
-30 to +65
110 x 110 x 7
1630
77
MARKERLIGHT – CIRCULAR
For more complete product information visit www.sylvania.com 259
L
E
D
S
Y
S
T
E
M
S
70019
ML/55X22/615/OS/ML01A/A
10
0.40
Amber Red
615
8
-30 to +65
85 x 37 x 7
715
52 x 22
Product Number
Ordering Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm) /
Color Coordinates
LEDs/Module
Operating
Temperature (deg C)
Dimensions (mm)
Luminance (cd/m2)
Luminous Area (mm)
70021
ML/55X22/525/OS/ML01A/T
10
0.80
True Green
525
8
-30 to +65
88 x 37 x 7
725
52 x 22
70023
ML/55X22/OS/ML01A/W
10
0.80
White
X = 0.32 Y = 0.31
8
-30 to +65
85 x 37 x 7
880
52 x 22
70022
ML/55X22/470/OS/ML01A/B
10
0.80
Blue
470
8
-30 to +65
85 x 37 x 7
140
52 x 22
70020
ML/55X22/587/OS/ML01A/Y
10
0.40
Yellow
587
8
-30 to +65
85 x 37 x 7
440
52 x 22
MARKERLIGHT – RECTANGULAR – SMALL
For more complete product information visit www.sylvania.com
260
L
E
D
S
Y
S
T
E
M
S
70024
ML/82X33/615/OS/ML01B/A
10
0.60
Amber Red
615
12
-30 to +65
112.5 x 48 x 7
405
79.5 x 33
Product Number
Ordering Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm) /
Color Coordinates
LEDs/Module
Operating
Temperature (deg C)
Dimensions (mm)
Luminance (cd/m2)
Luminous Area (mm)
70026
ML/82X33/525/OS/ML01B/T
10
1.20
True Green
525
12
-30 to +65
112.5 x 48 x 7
410
79.5 x 33
70028
ML/82X33/OS/ML01B/W
10
1.20
White
X = 0.32 Y = 0.31
12
-30 to +65
112.5 x 48 x 5
360
79.5 x 33
70027
ML/82X33/470/OS/ML01B/B
10
1.20
Blue
470
12
-30 to +65
112.5 x 48 x 7
90
79.5 x 33
70025
ML/82X33/587/OS/ML01B/Y
10
0.60
Yellow
587
12
-30 to +65
112.5 x 48 x 7
370
79.5 x 33
MARKERLIGHT – RECTANGULAR – MEDIUM
For more complete product information visit www.sylvania.com 261
L
E
D
S
Y
S
T
E
M
S
70029
ML/110X44/615/OS
/ML01C/A
10
0.80
Amber Red
615
16
-30 to +65
140 x 59 x 7
320
107 x 44
Product Number
Ordering
Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm) /
Color Coordinates
LEDs/Module
Operating
Temperature (deg C)
Dimensions (mm)
Luminance (cd/m2)
Luminous Area
70031
ML/110X44/525/OS
/ML01C/T
10
1.60
True Green
525
16
-30 to +65
140 x 59 x 7
330
107 x 44
70033
ML/110X44/OS
/ML01C/W
10
1.60
White
X = 0.32 Y = 0.31
16
-30 to +65
140 x 59 x 7
280
107 x 44
70032
ML/110X44/470/OS
/ML01C/B
10
1.60
Blue
470
16
-30 to +65
140 x 59 x 7
80
107 x 44
70030
ML/110X44/587/OS
/ML01C/Y
10
0.80
Yellow
587
16
-30 to +65
140 x 59 x 7
300
107 x 44
MARKERLIGHT – RECTANGULAR – LARGE
For more complete product information visit www.sylvania.com
262
L
E
D
S
Y
S
T
E
M
S
70034
ML/55SQ/615/OS/ML02A/A
24
1.92
Amber Red
615
40
-30 to +65
85 x 85 x 7
1170
52 x 52
Product Number
Ordering Abbreviation
Operating
Voltage (V)
Power (W)
Color
Wavelength (nm) /
Color Coordinates
LEDs/Module
Operating
Temperature (deg C)
Dimensions (mm)
Luminance (cd/m2)
Luminous Area (mm)
70036
ML/55SQ/525/OS/ML02A/T
24
3.84
True Green
528
40
-30 to +65
85 x 85 x 7
1170
52 x 52
70038
ML/55SQ/OS/ML02A/W1
24
3.84
White
X=0.32 Y=0.31
40
-30 to +65
85 x 85 x 7
3400
52 x 52
70037
ML/55SQ/470/OS/ML02A/B
24
3.84
Blue
470
40
-30 to +65
85 X 85 X 7
340
52 x 52
70035
ML/55SQ/587/OS/ML02A/Y1
24
2.88
Yellow
587
40
-30 to +65
85 x 85 x 7
2700
52 x 52
MARKERLIGHT – SQUARE
1
For more complete product information visit www.sylvania.com 263
L
E
D
S
Y
S
T
E
M
S
For more complete product information visit www.sylvania.com
264
L
E
D
S
Y
S
T
E
M
S
51516
OTDIM
10.5/24
5.3
0 - 52.5/0-120
5
0 - 10
3
Product Number
Description
Input Voltage (V)
Max. Input Current (Amps)
Output Power (W)
Max. Output Power (W)
Max. Output Current (Amps)
Control Voltage (VDC)
Max. Power Loss (W)
51518
OT RGB SEQUENCER
10.5/24
6
0-20 / 0-48
60/140
2 A per channel
0 - 10
3
51517
OT RGB 3 CHDIM
10.5/24
6
0-20 / 0-48
60/140
2 A per channel
0 - 10
3
OPTOTRONIC DIMMING AND RGB CONTROL MODULES
51500
OT6/100-240/10COS
100 - 240
.15@120V , .050@ 240V
10.5 +/ - 0.5
0.2
6
+/- .4V
26
Product Number
Description
Input Voltage (VAC)
Input Current (Amps)
Output Voltage (VDC)
Min. Power (W)
Max.Power (W)
Max. Line Ripple (V)
Remote Mounting (ft)
51508
OT50/120/10
120
.52@120V
10.5 +/ - 1.0
10
50
+/- 1.1V
8
51512
OT20/120-240/24S
120 - 240
.35@120V , .23@ 240V
24.0 +/ - 0.5
0.9
20
+/- .2V
32
51501
OT6/100 - 240/24COS
100 - 240
.15@120V , .050@
240V
24.0 +/ - 0.5
0.2
6
+/- .4V
26
51505
OT25/120/10
120
.26@120V
10.5 +/ - 1.0
3
25
+/- 1.1V
10
OPTOTRONIC LED POWER SUPPLY
For more complete product information visit www.sylvania.com 265
L
E
D
S
Y
S
T
E
M
S
For more complete product information visit www.sylvania.com
266
W
A
R
R
A
N
T
I
E
S
SYLVANIA HID SYSTEM
LIMITED WARRANTY
Combination Lamp and Ballast System Limited Warranty
OSRAM SYLVANIA Products Inc. (“OSPI”) warrants SYLVANIA
lamps installed on SYLVANIA magnetic ballasts to be free from
defects in material and workmanship and to operate from the date
of installation (or 3 months from date of manufacture if installation
date is not known or available) for the lamp and ballast warranty
periods and subject to the Terms and Conditions specified below.
If lamps fail to operate for the warranty period, OSPI will provide a
free replacement lamp (no labor allowance). If a SYLVANIA mag-
netic ballast fails to operate within the warranty period, OSPI will
provide a free replacement ballast (no labor allowance).
Please call customer service at 1-800-654-0089
or contact your local OSRAM SYLVANIA representative.
System Avg. Rated Lamp Life*Lamp Warranty Period Ballast Warranty Period
METALARC®7,000-12,000 hrs 6 months 24 months
METALARC®15,000-20,000 hrs 12 months 24 months
LUMALUX®24,000 hrs 12 months 24 months
LUMALUX®30,000 hrs 24 months 24 months
TERMS AND CONDITIONS
SYLVANIA lamps and SYLVANIA ballasts must be installed
together as a system and be installed and operated under suit-
able environmental conditions and in accordance with the latest
National Electrical Code, Underwriters Laboratory Bulletins, and
ANSI Specifications. This warranty will not apply in the event of
conditions demonstrating abnormal use or stress, such as oper-
ating temperatures in excess of maximum rated temperatures,
under/over voltage conditions, excessive switching cycles or
operating hours, dirty or cracked sockets, or improper lamp or
ballast installation. Replacement of SYLVANIA lamps with lamps
of other manufacturers will void the lamp portion of this warranty.
Replacement of the SYLVANIA ballast with any other ballast will
void the entire warranty.
FURTHER CONDITIONS
1. Warranty periods based on a minimum 4,000 hours/year
to a maximum 6,000 hours/year operation (minimum
10hr/start for lamp).
2. The lighting system must operate the lamp within current
ANSI Specifications.
3. OSRAM SYLVANIA reserves the right to examine all failed
lamps to verify cause of failure and shall be the sole judge as
to whether the lamps are in fact defective.
4. System warranty valid only for installations of 50 or more
lamps and ballasts. Contact OSRAM SYLVANIA for further
details.
5. Check with OSRAM SYLVANIA when using occupancy sen-
sors or dimming, as some situations may void the warranty.
WARRANTY ACTIVATION / SERVICE CLAIMS
The HID System warranty is automatically activated after
OSPI receives a completed HID System warranty registration
form within 30 days after installation. An acknowledgment
will be sent for each registration along with a reference num-
ber for future correspondence. Service claims can be made
by contacting 1-800-LIGHTBULB to initiate the process for
problem resolution.
LABOR OPTIONS
No labor allowance is made for lamp or ballast replace-
ment.
RETURN OF DEFECTIVE PRODUCT
After contacting OSRAM SYLVANIA and receiving a
RETURN MATERIAL AUTHORIZATION NUMBER, the
user shall promptly return the product at the user’s expense
to OSRAM SYLVANIA after receiving instructions as to if,
when and where to ship product. Failure to follow this proce-
dure shall void this warranty.
REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY
The foregoing shall constitute the sole and exclusive remedy
of the purchaser and the sole and exclusive liability of OSPI.
NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED.
OSPI will not, under any circumstance, whether as a result of
breach of contract or warranty, tort, or otherwise, be liable for
any incidental, special or consequential damages, including
lost profits or revenues or any other costs or damages.
OSPI reserves the right to examine all failed lamps and/or
ballasts and reserves the right to be the sole judge as to
whether any lamps and/or ballasts are defective and covered
under this warranty.
*Subject to and limited by the lamp warranty period limitations set forth above.
QUESTIONS?
For more complete product information visit www.sylvania.com 267
W
A
R
R
A
N
T
I
E
S
Registration Form
SYLVANIA HID SYSTEM
LIMITED WARRANTY
Please Complete and Return To:
OSRAM SYLVANIA
Attn: Warranty Dept.
18725 N. Union Street, Westfield, IN 46074
Tel #: 800/654-0089 Email: warranty.service@sylvania.com
Or Complete and Fax To:
OSRAM SYLVANIA
Fax #: 866/632-9674
OSRAM SYLVANIA National Customer Service and Sales Center
www.sylvania.com
Photocopy the form below and use it to register any installation featuring SYLVANIA magnetic ballast systems. Also available is our
on-line version which you may find by visiting our web site at www.sylvania.com. The warranty coverage begins from the date of
installation, but you must register an installation in order to receive warranty service.
Installation Information
Location Name:_______________________________________________________________________________________________
Address: _________________________________City:___________________________State:____________________Zip: ________
Send Registration To: __________________________________________________________________________________________
Address: _________________________________City:___________________________State:____________________Zip: ________
Contact Name:____________________________Phone: ________________________Email: _______________________________
Installation Date: ___________________________
Operating Hours: __________________________starts/day______________________hours/day ___________________days/year
Occupancy Sensors* _________________(Yes/No) Dimming* __________________(Yes/No)
Comments___________________________________________________________________________________________________
Type&Quantities (Description and NAED Item # as Shown on Product Packaging)
Ballast NAED Lamp NAED
Description Item # Quantity Description Item # Quantity Comments
e.g. M750/MULTI-PS-KIT 47717 1000 MS750/PS/BU-HOR/BT37 64787 1000
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
_______________________________________________________________________________________________________________
* check with OSRAM SYLVANIA when using occupancy sensors or dimming, as some situations may void the warranty.
For more complete product information visit www.sylvania.com
268
W
A
R
R
A
N
T
I
E
S
QUICK 60+®
Limited Warranty
The Heart of a Comprehensive System Service Program
Compare lighting system warranties – you’ll see that our QUICK 60+ warranty offers
better coverage, more service options and, more important, peace of mind.
Combination Lamp and Ballast System Limited Warranty
OSRAM SYLVANIA Products Inc. (“OSPI”) warrants SYLVANIA lamps installed on
QUICKTRONIC®ballasts to be free from defects in material and workmanship and
to operate from the date of installation (or date of manufacture if installation date
is not known or available) for the time periods and subject to the Terms and
Conditions specified below. If lamps fail to operate for the warranty period, OSPI
will provide a free replacement lamp (but no labor allowance). If a QUICKTRONIC
ballast fails to operate within the warranty period, OSPI will provide a free
replacement ballast and labor allowance in accordance with the “Labor Options”
set forth below.
Please call customer service at 1-800-654-0089 or contact
your local OSRAM SYLVANIA representative.
System3Lamp Ballast Warranty Period* Lamp Warranty Period*
QUICKTRONIC®T81OCTRON®XP, XP/SS2, 3 60 months 36 months
QUICKTRONIC PSX T81OCTRON XPS®4, XP & XP/SS2, 3 60 months 36 months
QUICKTRONIC T81OCTRON family 60 months 30 months
QUICKTRONIC 59 OCTRON FO96/XP, FO96/XP/SS 60 months 30 months
QUICKTRONIC 59 OCTRON FO96 60 months 24 months
QUICKTRONIC 86/T8HO OCTRON FO96HO 60 months 30 months
QUICKTRONIC 96IS/96HO & 40T12 N/A 60 months N/A
QUICKTRONIC T5, T5/HO, DIM1PENTRON®Family 60 months 24 months
QUICKTRONIC DL40 DULUX®FT40DL 60 months 12 months
QUICKTRONIC 54PHO DULUX FT55DL 60 months 12 months
QUICKTRONIC CF DULUX D/E, T/E 60 months 12 months
QUICKTRONIC FM FM 24 months 6 months
QUICKTRONIC ICE1, 5 ICETRON®60 months 60 months
QUICKTRONIC MH6, 7 METALARC®CERAMIC Family660 months @ <80° C76 months
*Note – Fluorescent warranty periods are based on a 3 hour minimum cycle, unless otherwise noted, with a maximum of 4000 hours per year. Other operating
cycles may affect warranty period. Lamp warranty can renew when installation is group relamped, contact OSRAM SYLVANIA for details.
1Occupancy sensor application, 15 minute/start minimum, allowed with QUICKTRONIC PROStart®and with QUICKTRONIC ICE ballasts.
2OCTRON SUPERSAVER®bipin lamps operate on QUICKTRONIC & QUICKTRONIC Professional Instant Start & PROStart (PSN, PSX) models only.
3QUICKTRONIC and QUICKTRONIC Professional Series including all IS, RS, PS & DIM models where applicable.
4OCTRON XPS lamps on any other suitable QUICKTRONIC ballast have a 30 month Lamp Warranty Period.
5ICETRON Lamp Warranty Period allows up to 8760 hrs per year (continuous operation), with a 3 hour per start minimum.
6Contact OSRAM SYLVANIA for a list of METALARC CERAMIC lamps approved on the QUICKTRONIC MH HID ballasts.
7QUICKTRONIC MH ballasts warranty is 36 months @ tc < 90 C. Electronic HID system warranty period is based on a minimum cycle of 10hr/start
up to a maximum operation of 6,000 hours/year.
QUESTIONS?
TERMS AND CONDITIONS
SYLVANIA lamps and QUICKTRONIC ballasts must be installed together as a
system and be installed and operated under suitable environmental conditions
and in accordance with the latest National Electrical Code, Underwriters
Laboratory Bulletins, and ANSI Specifications. This warranty will not apply in
the event of conditions demonstrating abnormal use or stress, such as
operating temperatures in excess of maximum rated temperatures,
under/over voltage conditions, excessive switching cycles (see above Note
#1) or operating hours, dirty or cracked sockets, or improper lamp or ballast
installation. Replacement of SYLVANIA lamps with lamps of other
manufacturers will void the lamp portion of this warranty. Replacement of the
QUICKTRONIC ballast with any other ballast will void the entire warranty.
WARRANTY ACTIVATION / SERVICE CLAIMS
The QUICK 60+ warranty is automatically activated after OSPI receives
a completed QUICK 60+ warranty registration form within 30 days after
installation. An acknowledgment will be sent for each registration
along with a reference number for future correspondence. Service
claims can be made by contacting 1-800-LIGHTBULB to initiate the
process for problem resolution.
LABOR OPTIONS (Ballast and ICETRON lamps only)
No labor allowance is made for any lamp replacement except ICETRON,
during the warranty period. OSPI provides for several labor options for service
under the QUICK 60+ warranty program.
1. OSPI will provide full service coverage through SYLVANIA LIGHTING
SERVICES at no cost to the user of the ballast, or
2. OSPI will contact a service provider and coordinate replacement at
no cost to the user of the ballast, or
3. OSPI will reimburse the purchaser reasonable, customary and
necessary labor charges required to install the ballast replacement.
4. Labor options must be pre-approved by OSPI. Any labor option or
cost that is not pre-approved will not be eligible for reimbursement.
RETURN OF DEFECTIVE PRODUCT
After contacting OSRAM SYLVANIA and receiving a return
AUTHORIZATION NUMBER, the user shall promptly return the product at
the user’s expense to OSRAM SYLVANIA after receiving instructions as to
if, when and where to ship product. Failure to follow this procedure shall
void this warranty.
REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY
The foregoing shall constitute the sole and exclusive remedy of the
purchaser and the sole and exclusive liability of OSPI. NO WARRANTY
OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE IS
MADE OR IS TO BE IMPLIED. OSPI will not, under any circumstance,
whether as a result of breach of contract or warranty, tort, or otherwise,
be liable for any incidental, special or consequential damages, including
lost profits or revenues or any other costs or damages.
OSPI reserves the right to examine all failed lamps and/or ballasts and
reserves the right to be the sole judge as to whether any lamps and/or
ballasts are defective and covered under this warranty.
For more complete product information visit www.sylvania.com 269
W
A
R
R
A
N
T
I
E
S
Registration Form
QUICK 60+® LIMITED
WARRANTY
Photocopy the form below and use it to register any installation featuring QUICKTRONIC®ballast systems. Also available, is our
on-line version which you may find by visiting our web site at www.sylvania.com. The warranty coverage begins from the date of installa-
tion, but you must register an installation in order to receive warranty service.
Installation Information
Location Name:______________________________________________________________________________________________
Address:______________________________________City:___________________________State:______________Zip:_________
Send Registration To: _________________________________________________________________________________________
Address:______________________________________City:___________________________State:______________Zip:_________
Contact Name: _________________________________Phone:_________________________Email: _________________________
Installation Date: ___________________________________
Operating Hours: ___________________________________hours/day ______________________days/year
Occupancy Sensors: Yes No
Comments ______________________________________________________________________________________________
Type&Quantities (Description and NAED Item # as Shown on label (or packaging)
Ballast NAED Lamp NAED
Description Item # Quantity Description Item # Quantity Comments
Please Complete and Return To:
OSRAM SYLVANIA
Attn: Warranty Dept.
18725 N. Union Street
Westfield, IN 46074
Tel #: 800/654-0089 Email: warranty.service@sylvania.com
OSRAM SYLVANIA National Customer Service and Sales Center
Or Complete and Fax To:
OSRAM SYLVANIA
Electronic Control Systems
Fax #: 866/632-9674
e.g. QTP2X32T8/UNV ISN-SC 49943 800 FO32/830/XP/ECO 21759 1600
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________
For more complete product information visit www.sylvania.com
270
W
A
R
R
A
N
T
I
E
S
Magnetic Ballast Limited Warranty
OSRAM SYLVANIA Products Inc. (“OS”) warrants SYLVANIA fluores-
cent magnetic ballasts and high intensity discharge (HID) magnetic
ballasts to be free from defects in material and workmanship and to
Please call customer service at 1-800-654-0089
contact your local OSRAM SYLVANIA representative.
operate from the date of manufacture for the time periods specified
below.
Magnetic Ballast Type Ballast Warranty Period*
Fluorescent Magnetic 36 months
High Intensity Discharge (HID) Magnetic 24 months
Magnetic Sign 24 months
*Note - Warranty periods are based on typical 4000 hr/12 months operation; longer operating cycles may limit warranty period.
Contact OS for details.
TERMS AND CONDITIONS
SYLVANIA magnetic fluorescent and HID ballasts must be installed
and operated under suitable environmental conditions and in accor-
dance with the latest National Electrical Code, Underwriters
Laboratory Bulletins, ANSI Specifications, CSA standards, and in
accordance with OS installation instructions, where applicable. This
warranty will not apply if conditions demonstrate abnormal use or
stress, such as operating temperatures in excess of maximum rated
temperatures, under/over voltage conditions, excessive switching
cycles or operating hours, dirty or cracked sockets, or improper lamp
or ballast installation.
WARRANTY ACTIVATION / SERVICE CLAIMS
Warranty is activated after installation. Service claims can be made by
contacting 1-800-654-0089 (press “2”) to initiate the process for
problem resolution.
REPLACEMENT OF PRODUCT
OS shall correct any defects by replacing or repairing, at OS’s option,
any ballast determined to be defective under the terms of this warran-
ty. Note: Labor costs are not reimbursed by OS.
RETURN OF DEFECTIVE BALLAST
After contacting OS and receiving a return AUTHORIZATION NUM-
BER, the purchaser may be requested to promptly return the ballast
at the purchaser’s expense to OS after receiving instructions as to if,
when and where to ship the ballast. Failure to follow this procedure
shall void this warranty.
LIMITS OF LIABILITY
The foregoing shall constitute the sole and exclusive remedy of the
purchaser and the sole and exclusive liability of OS. NO IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR PURPOSE IS MADE OR IS TO BE IMPLIED. OS will not, under
any circumstance, whether as a result of breach of contract or war-
ranty, tort, or otherwise,be liable for any costs or damages, including
lost profits or revenues, incidental, special or consequential damages.
OS reserves the right to examine all failed ballasts and reserves the
right to be the sole judge as to whether any ballasts are defective and
covered under this warranty. This warranty does not cover lamps
operated by the ballast.
QUESTIONS?
For more complete product information visit www.sylvania.com 271
W
A
R
R
A
N
T
I
E
S
LED SYSTEM WARRANTY
Limited Warranty
OSRAM SYLVANIA Products, Inc. (OSI) is pleased to provide the following
warranty for the periods shown below. This warranty covers OSI’s LED Modules and
Optotronic®Power supplies or controls when installed as a system.
OSI LED System Limited Warranty
OSI warrants each OSI LED Module or Optotronic‚ Power supply
or control to be free from defects in materials and workmanship,
and to operate from the date of installation (or date of manufac-
turer if installation date is not known or available, or verifiable)
for the time periods and subject to the Terms and Conditions
specified below. If an OSI LED module or an Optotronic‚ Power
supply or control fails to operate for the specified warranty peri-
od, OSI will provide a free replacement component in accor-
dance with the Terms and Conditions set forth below (labor not
included).
Please call customer service at 1-800-654-0089
or contact your local OSRAM SYLVANIA representative.
OSRAM LED SYSTEMS FOR LIGHTING WARRANTY
LED Module Power Supply and LED Module
System4Family Control Warranty Period Warranty Period
Optotronic‚ OT and BACKlight, LINEARlight, 60 months 60 Months
OSRAM LED Lamp LINEARlight Flex, (Colormix),
Modules, Power Supply EFFECTlight, COINlight,
or Controls MARKERlight
TERMS AND CONDITIONS
This warranty only applies when OSI’s OSRAM LED Lamp Module
is properly wired and installed; is operated on a suitable power
supply within the electrical values recommended by OSI; used in
lighting equipment designed and approved for the application and
in environmental conditions (temperature, humidity) within the
normal specified operating range of the system. This warranty
does not apply to any abnormal use or use in violation of any
applicable standard, code or instructions for use in installations
including those contained in the latest National Electrical Code
(NEC), the Standards for Safety of Underwriters Laboratory, Inc.
(UL), Standards for the American National Standards Institute
(ANSI) or, in Canada, the Canadian Standards Association (CSA).
This warranty will not apply in the event of conditions demon-
strating abnormal use or stress, including under/over
voltage/current conditions, excessive switching cycles or operat-
ing hours or outside the following recommended operating con-
ditions:
Warranty Period is based on typical 8,760 hr./yr.
operation on a continuous burning cycle of 24
hours.
Mean operating temperature for LED Module: 25˚C
• Maximum operating temperature for LED Module:
65˚C
• Operate at rated DC Voltage
Mean ambient operating temperature for
Optotronic‚ Power supplies and controls is 40˚C
Replacement of OSI LED Module components with LED compo-
nents of other manufacturers will void the entire warranty.
Inappropriate use and selection of power supply will void the
entire warranty.
WARRANTY SERVICE CLAIMS
Warranty claims can be serviced by calling OSI’s National
Customer Service & Sales Center:
1-800-654-0089
Fax: 866-632-9674
Email: warranty.service@sylvania.com
If you are unsure whether a situation exists that is covered by
this warranty, please contact OSI’s National Customer Service &
Sales Center for assistance.
RETURN OF DEFECTIVE PRODUCT
After contacting OSI, the purchaser/user shall promptly return
the product after receiving instructions regarding if, when and
where to ship product. Failure to follow this procedure shall void
this warranty.
REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY
The foregoing shall constitute the exclusive remedy of the pur-
chaser and the sole liability of OSI for the OSI LED Lamp Module
component and Optotronic‚ power supply or controls. NO WAR-
RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR PURPOSE IS MADE OR IS TO BE IMPLIED. In no event shall
OSI be liable for any other costs or damages, including lost prof-
its or revenues, incidental, special or consequential damages.
OSI reserves the right to examine all failed OSI Module LED and
Optotronic‚ power supply, controls and components to deter-
mine the cause of failure and patterns of usage and reserves the
right to be the sole judge as to whether any such controls or
components are defective and covered under this warranty.
QUESTIONS?
For more complete product information visit www.sylvania.com
272
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide
These tables are intended only as guides and may represent another lamp/ballast company's most similar product rather than an identical
match. Individual manufacturer's performance values should be consulted. For a complete cross reference guide please consult our electronic
catalog at www.sylvania.com.
INCANDESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
4C7 CARD 2 4C7/BL/2PK BC-4C7
4C7/W CD2 4C7/W/BL/2PK BC-4C7/W
10C7 TRAY 10C7/CL 10C7
10S11N 10S11N/CL 10S11N
10S11N/F 10S11N/IF 10S11N/IF
15CAC/F-CD/2-12 15B10/BL/2PK BC-15BA9C/LL
--- 15B10C/DL/BL 15BA9C/4M
15S14/GR/CL 15S14/CL 15S11/14
15T10 15T10/CL BC-15T10 12/1PK
20T612DC/F 20T612/DC/IF 20T612DC/IF
20T612/F 20T612/I 20T612/IF
25CAC 25B10C/DL/BL ---
--- 25B10/DL/BL BC-25B912/LL
25CAC-CD/2-120 25B10C/BL/2PK BC25BA9C/LL
25GC 12PK 25G1612C 25G1612C/4M
25G1812/W 25G1812/W ---
25G25 25G25 25G25
25G25/L/24 25G25/DL/RP ---
25G25/W/L/24 25G25/DLSW/RP ---
25G40 25G40 25G40/4M
25G40/W 25G40/W 25G40/4MW
25S11/5C 25S11C/P 25S11/2C
25T10 25T10 BC-25T10
30/100 30/100A21/W/RP 30/100A/W
30A15-130 30A15 30A15
30R20-120 30R20 30R20
40A15/CF CD2 40A15/CL/FAN BC-40S14/FAN
40A15/CF/STG CD2 40A15/SL 40A/TF
40A 48PK 40A 40A
40A/34WM 40A/34/SS 40A-34A/EW
40A/34/WMP/99 40A/34/SS/XL 40A-34A/99/EW
40CAM CD/2 40B10/BL/2PK BC-40BA91/2/LL
40CAC-CD/2-120 40B10C/BL/2PK BC-40BA9C/LL
--- 40B10/DL/BL/2PK 40BA91/2/4M
--- 40B10C/DL/BL 40B1012/4M
40CAM/F CD/2 40B10/W/BL/2PK BC-40BA1/2/FLL
40FM/L 40F/CL BC-40F15/LL
40GC-12PK-120 40G1612C 40G16 1/2 C
40GC/W/CD/2 40G1612/C/W/BL BC-40G161/2/WLL
40G25/L 40G25 40G25
40G25/L/24 40G25/DL/RP ---
40G25/W/L/24 40G25/DLSW/RP 40G25/W
40G25/W/L 40G25/W 40G25/W
40G25/W/L 40G30/W 40G25/W
40G40/CL 40G40 40G40/4M
40G40/W 40G40/W 40G40/4MW
40S11N/1CARD 40S11N/BL BC40S11/N TP
40S11N/1/F 40S11N/CF 40S11N/IF
40T10/F 40T10/IF BC-40T10/IF
50/150 12PK 50/150A21/W/RP 50/150A/W
50/150 12PK 50/150/PS25 50/150T/DL
50A/RS/CVG 24PK 50A/RS/SL 50A/RS/TF
60A 60A 60A
60A/52WM 60A/52/SS 60A-52A/EW
60A/52WMP/98 60A/52/SS/XL ---
60A21/B 60A/CB 60A19/B
60A21/G 60A/CG 60A19/G
60A/CL 24PK 60A/CL 60A/CL
60A/W/LL-24PK-120 60A/DLSW/2PK/RP 60A/WL
For more complete product information visit www.sylvania.com 273
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
INCANDESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
60A/PL 6PK 60A/GRO 60A/AGRO
60A/CVG 24PK 60A/SL 60A/TF
60A/GD 24PK 60A/RS ---
60A/S 60A/RS/XL ---
60A/W 48PK 60A/W/4RP 60A/W/TP
60A/Y 24PK 60A/Y/RP 60A/Y 120-130V
69A21/60WM/TS 60A19/TS/8M/SS K60A19/TS/EW
--- 60A21/TS K60A19/TS/EW
60CAM CD/2 60B10/BL/2PK BC-60BA9/2/LL
60CAC CD/2 6PK 60B10C/BL/2PK BC-60BA9C/LL
--- 60B10/DL/BL/2PK 60BA91/24M
--- 60B10C/DL/BL/2PK 60BA9C/4M
--- 60B10C/F/BL/2PK BC-60BA9 1/2/FLL
60CAC/F CD/2 60B10C/W/BL/2PK ---
60CAM/F CD/2 60B10/W/BL/2PK BC-60BA9C/FLL
--- 60F/BL BC-60F15/LL
40FM/AU CD/2 6 PK 60F/IC/BL/2PK BC60F15/LL
60GC 60G1612C/BL ---
60G25 6PK 120V 60G25/RP 60G25 120V
--- 60G25/DL/RP 60G25
--- 60G25/DLSW/RP 60G25/W
60G30/W 60G30/W ---
60G40 6PK 60G40/RP 60G40/4M
60G40/W 6PK 60G40/W 60G40/4MW
--- 60K19/DR 60K19/DL
60T10/F 24PK 60T10/CF 60T10/64/IF
65R30/FL/LL 6PK 65BR30/DL/FL/RP 65BR30/FL/LL55
--- 65BR30/FL 65BR30/FL55
75R30/FL/65WM 65BR30/FL/SS 65BR30/FL55
65R30/SP/LL 6PK 65BR30/SP/RP 65BR30/SP20
75R30/SP/65WM 65BR30/SP/SS 65BR30/SP20
75A 75A 75A
75A/CL 24PK 75A/CL 75A/CL
75A/RS 75A19/RS 75A/RS/VS
75A/RT 6PK 75A21/RS/SL 75A/RH/TF
75A/RS/CVG 24PK 75A21/SL/RP 75A/RH/TF
75A/67WM 75A/67/SS 75A-67A/EW
75A/67WMP/99 75A/67/SS/XL 75A-67A/99/EW 120
75R30/A 75BR30/A/FL/RP ---
75R30/B 75BR30/B/FL/RP 75BR30/PK
75R30/G 75BR30/G/FL/RP ---
75R30/PL/1 6PK 75BR30/GRO/FL/RP 75BR30/AGRO
75R30/PK 75BR30/PK/FL/RP 75BR30/PK
75R30/SP-1 6PK 75BR30/SP/RP ---
75R30/Y 75BR30/Y/FL/RP ---
75R/FL/1-6PK-120 75BR/FL/RP ---
75ER30 75ER30 75ER30
--- 75K19/DR 75K19/DL
75R20 6PK 75R20/RP 75R20
--- 75R30/FL/SL 75BR30/FL/TF
100A21/90WM/TS 12 90A19/TS/8M/SS K90A19/TS/EW
100A21/SBIF 60 PK 100A21/1SB/IF 100A/1SBIF
100A 100A 100A
--- 100A/DLSW/2PK/RP 100A/W
100A/RS 12PK 100A19/RS 100A/RS/VS
100A21 100A21 100A21
100A/RS/CVG 100A21/RS/SL 100A/RS/TF
100A23/VS 24PK 100A21/VS 100A/RS/VS
100A23/20 100A23/20 100A23/20
100A/90WM 100A/90/SS 100A-90A/EW
100A/90WMP/98 100A/90/SS/XL 100-90A/99EW
100A/CL 24PK 100A/CL 100A/CL
100R/FL-120 100BR/FL 120BR/FL60
For more complete product information visit www.sylvania.com
274
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
INCANDESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
100G40 100G40 100G40/4M
100G40/W/L 100G40/W 100G40/4MW
120R40/FL/MI-6PK 120BR/FL 120BR/FL60
120R40/FL/LL-6PK 120BR/DL/FL/RP ---
120R40/SP/MI-6PK 120BR/SP 120BR/SP20
120ER40 120ER40 120ER40
125R40 125BR40 125R40/1
150A 150A21 150A
150A/135WM 150A21/135/SS 150A-135A/EW
150Q21/99/IF 150A21/99/XL 150A/99
150A/CL 12PK 150A21/CL 150A/CL
150R40/PL-1 6PK 150BR/GRO 150BR/AGRO
150G40/W 150G40/W/RP 150G40/W
200A 12PK 200A21 200A (A23)
200/99 200CL/99/XL 200/99
200/IF 200PS/IF 200/IF
200/99 200PS/CL/99/XL 200/99
200/99IF 200PS/IF/99/XL 200/99IF
250R40/1 250BR40 250R40/1
--- 250KBR38/FL K250PAR38/FL
--- 250KR38/SP K250PAR38/SP
300M/99 300/AX/CL 300/2
300M/99IF 300/AX/IF 300/2IF
300R/FL 300BR/FL 300R/FL
300M/99/IF 300M/99/IF/XL 300M/99IF
300M 300/M/CL 300M
300PAR56/MFL 300PAR56/MFL 300PAR56/MFL
300PAR56/NSP 300PAR56/NSP 300PAR56/NSP
300PAR56/WFL 300PAR56/WFL 300PAR56/WFL
300/99IF 300PS35/99/IF/XL 300/99IF
For more complete product information visit www.sylvania.com 275
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
HALOGEN LAMPS
GE SYLVANIA PHILIPS OSRAM
HALOGEN BT15
--- 60BT15/HAL/CL/BL BC60BT15/HAL/CL ---
--- 60BT15/HAL/W/BL BC60BT15/HAL/W ---
--- 75BT15/HAL/W/BL BC75BT15/HAL/W ---
--- 100BT15/HAL/W/BL BC100BT15/HAL/W ---
--- 150BT15/HAL/W/BL BC150BT15/HAL/W ---
CAPSYLITE MIDBREAK
50A/HAL 52A/CAP --- ---
60A/HAL 60A/HAL/DAY --- ---
60A/HAL/CL 60A/HAL/DAY/CL --- ---
75A/HAL 75A/HAL/DAY --- ---
90A/HAL 100A/HAL/DAY --- ---
CAPSYLITE PAR
60PAR16/H/SP10 60PAR16/CAP/NSP10 60PAR16/HAL/NSP10 ---
60PAR16/H/FL30 60PAR16/CAP/NFL30 60PAR16/HAL/NFL27 ---
75PAR16/H/SP10 75PAR16/CAP/NSP10 --- ---
75PAR16/H/FL30 75PAR16/CAP/NFL30 --- ---
50PAR20/H/FL25 50PAR20/HAL/SPL/NFL30 50PAR20/HAL/NFL30 ---
50PAR20/H/SP10 50PAR20/HAL/SPL/NSP10 50PAR20/HAL/NSP9 ---
50PAR30/H/FL25 50PAR30/CAP/SPL/NFL25 50PAR30/HAL/NFL30 ---
50PAR30/H/SP10 50PAR30/CAP/SPL/NSP9 50PAR30S/HAL/NSP10 ---
50PAR30/H/FL35 50PAR30/HAL/SPL/FL40 50PAR30S/HAL/FL40 ---
50PAR30L/H/FL40 50PAR30LN/CAP/SPL/NFL30 50PAR30L/HAL/NFL30 ---
50PAR30L/H/SP10 50PAR30LN/CAP/SPL/NSP9 50PAR30L/HAL/NSP9 ---
50PAR30L/H/WFL 50PAR30LN/CAP/SPL/WFL50 50PAR30L/HAL/WFL60 ---
60PAR30/H/NSP9 60PAR30/CAP/SPL/NSP9 60PAR30S/HAL/NSP10 ---
60PAR30/H/FL25 60PAR30/CAP/SPL/NFL25 60PAR30S/HAL/NFL30 ---
75PAR30/H/SP10 75PAR30/CAP/SPL/NSP9 75PAR30S/HAL/SP10 ---
75PAR30/H/FL25 75PAR30/CAP/SPL/NFL25 75PAR30S/HAL/NFL30 ---
75PAR20/H/FL35 75PAR30/CAP/SPL/FL40 75PAR30S/HAL/FL40 ---
75PAR30L/H/SP10 75PAR30LN/CAP/SPL/NSP9 75PAR30L/HAL/NSP9 ---
75PAR30L/H/FL25 75PAR30LN/CAP/SPL/NFL25 75PAR30L/HAL/NFL30 ---
75PAR30L/H/WFL 75PAR30LN/CAP/SPL/WFL50 75PAR30L/HAL/FL40 ---
35PAR36/H/SP8 36PAR36CAPNSP13 --- ---
35PAR36/H/SP5 36PAR36CAPVNSP5 --- ---
35PAR36/H/FL30 36PAR36CAPWFL --- ---
50PAR36/H/SP5 50PAR36CAPNSP6 --- ---
45PAR/H/SP10 45PAR/CAP/SPL/SP9 --- ---
--- 45PAR/CAP/SPL/WSP12 45PAR38/HAL/SP12/LL ---
45PAR/H/FL25 45PAR/CAP/SPL/FL30 45PAR38/HAL/FL28/LL ---
60PAR/H/SP10 60PAR/CAP/SPL/SP9 60PAR38/HAL/NSP10/WLL ---
--- 60PAR/CAP/SPL/WSP12 60PAR38/HAL/SP12/WLL ---
60PAR/H/FL25 60PAR/CAP/SPL/NFL25 --- ---
--- 60PAR/CAP/SPL/FL30 60PAR38/HAL/FL28/WLL ---
75PAR/H/SP9 75PAR/CAP/SPL/SP9 75PAR38/HAL/SP10/WLL ---
75PAR/H/FL25 75PAR/CAP/SPL/FL30 75PAR38/H/FL28/WLL ---
90PAR/H/SP10 90PAR/CAP/SPL/SP9 --- ---
--- 90PAR/CAP/SPL/WSP12 90PAR38/HAL/SP12/LL ---
90PAR/H/FL25 90PAR/CAP/SPL/FL30 90PAR38/HAL/FL28/LL ---
90PAR/H/WFL 90PAR/CAP/SPL/WFL50 90PAR38/HAL/WFL60/WLL ---
120PAR/H/SP9 120PAR/CAP/SPL/SP9 --- ---
120PAR/H/FL30 120PAR/CAP/SPL/FL30 --- ---
Q250PAR/SP10 250PARCAPSPLSP10 --- ---
Q250PAR/FL30 250PARCAPSPLFL30 --- ---
Q500PAR56MFL 500PAR56QMFL 500PAR56Q/MFL ---
Q500PAR56NSP 500PAR56QNSP 500PAR56Q/NSP ---
Q500PAR56WFL 500PAR56QWFL 500PAR56Q/WFL ---
Q1000PAR64MFL 1000PAR64QMFL 1000PAR64Q/MFL ---
Q1000PAR64NSP 1000PAR64QNSP 1000PAR64Q/NSP ---
Q1000PAR64WFL 1000PAR64QWFL 1000PAR64Q/WFL ---
CAPSYLITE IR PAR
45PAR30/HIR/SP9XL 50PAR30/CAP/IR/NSP9 130V --- ---
45PAR30/HIR/FL25XL 50PAR30/CAP/IR/NFL25 130V --- ---
For more complete product information visit www.sylvania.com
276
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
HALOGEN LAMPS
|
|
GE SYLVANIA PHILIPS OSRAM
|
CAPSYLITE IR PAR (continued)
45PAR30/HIR/FL35XL 50PAR30/CAP/IR/FL40 130V --- ---
50PAR30/HIR/SP9 50PAR30/CAP/IR/NSP9 50PAR30S/IRC/NSP10 ---
50PAR30/HIR/FL25 50PAR30/CAP/IR/NFL25 50PAR30S/IRC/NFL30 ---
50PAR30/HIR/FL35 50PAR30/CAP/IR/FL40 50PAR30S/IRC/FL40 ---
45PAR/HIR/SP12/XL 50PAR/CAP/IR/SP10 130V --- ---
45PAR/HIR/FL40/XL 50PAR/CAP/IR/NFL25 130V --- ---
50PAR/HIR/SP9 50PAR/CAP/IR/SP10 50PAR38/IRC/SP12 ---
50PAR/HIR/FL25 50PAR/CAP/IR/NFL25 50PAR38/IRC/FL25 ---
55PAR/HIR/SP12/XL 55PAR38/CAP/IR/XP/SP9 --- ---
55PAR/HIR/FL40/XL 55PAR38/CAP/IR/XP/FL30 --- ---
60PAR/HIR/SP10 60PAR/CAP/IR/SP10 60PAR38/IRC/SP10 ---
60PAR/HIR/SP12 60PAR/CAP/IR/WSP12 60PAR38/IRC/WSP12 ---
--- 60PAR/CAP/IR/NFL25 60PAR38/IRC/FL25 ---
60PAR/HIR/FL30 60PAR/CAP/IR/FL30 --- ---
80PAR/HIR/SP10 80PAR/CAP/IR/SP10 --- ---
80PAR/HIR/FL25 80PAR/CAP/IR/FL25 --- ---
100PAR/HIR/SP10 100PAR/CAP/IR/SP10 100PAR38/IRC/SP10 ---
100PAR/HIR/FL25 100PAR/CAP/IR/NFL25 100PAR38/IRC/FL25 ---
100PAR/HIR/FL40 100PAR/CAP/IR/FL40 --- ---
TRU-AIM MR11
Q20MR11/SP15(FTC) 20MR11/SP10/FTB 20MRC11/SP10 46890SP
Q20MR11/NFL30(FTD) 20MR11/FL35/FTD 20MRC11/FL30 46890WFL
Q35MR11/NFL30(FTH) 35MR11/FL40/FTH --- 46892WFL
Q35MR11/SP20(FTF) 35MR11/SP10/FTE --- 46892SP
STANDARD TRU-AIM MR16
Q20MR16/SP 20MR16/NSP8/ESX 20MRC16/SP10 41860SP
Q20MR16/FL 20MR16/FL40/BAB 20MRC16/FL36 41860WFL
Q35MR16CG/FL 35MR16/FL40 --- 41865WFL
Q50MR16/SP 50MR16/NSP12/EXT 50MRC16/SP10 41870SP
--- 50MR16/NFL25/EXZ 50MRC16/NFL24 ---
Q50MR16/FL 50MR16/FL40/EXN 50MRC16/FL38 41870WFL
--- 65MR16/NSP10/FPA 75MR16/SP10-EYF ---
--- 65MR16/FL40/FPB 75MR16/FL36-EYC ---
TRU-AIM BRILLIANT MR16
--- 20MR16/B/FL35/C --- 41861WFL
--- 50MR16/B/NSP11/C/EXT 50MRC16/SP12/A ---
--- 50MR16/B/NFL25/EXZ 50MRC16/NFL24/A ---
--- 50MR16/B/FL35/C/EXN 50MRC16/FL36 41871WFL
TRU-AIM TITAN MR16
Q20MR16/C/VNSP7 20MR16/T/NSP10/ESX 20MRC16/CC/SP10 46860SP
Q20MR16/C/FL40 20MR16/T/FL40/BAB 20MRC16/CC/FL38 46860WFL
--- 35MR16/T/NSP10/FRB --- 46865SP
Q35MR16/C/SP20 35MR16/T/NFL25 --- 46865FL
Q35MR16/C/FL40 35MR16/T/FL40/FMW --- 46865WFL
Q50MR16/C/NSP15 50MR16/T/NSP10/EXT 50MRC16/CC/SP10 46870SP
Q50MR16/C/NFL25 50MR16/T/NFL25/EXZ 50MRC16/CC/NFL24 46870FL
Q50MR16/C/FL40 50MR16/T/FL40/EXN 50MRC16/CC/FL38 46870WFL
Q50MR16/C/WFL55 50MR16/T/VWFL60/FNV --- 46870VWFL
Q71MR16/C/NSP15 65MR16/T/NSP10/FPA --- ---
Q71MR16/C/NFL25 65MR16/T/NFL25 --- ---
Q71MR16/C/FL40 65MR16/T/FL40/FPB --- ---
TRU-AIM IR MR16
--- 20MR16/IR/SP10/C 20MRC16/IRC/SP8 48860SP
--- 20MR16/IR/NFL25/C --- 48860FL
--- 20MR16/IR/FL40/C 20MRC16/IRC/FL36 48860WFL
--- 20MR16/IR/WFL60/C --- 48860VWFL
Q37MR16/HIR/CG10 37MR16/IR/SP10/C 35MRC16/IRC/SP8 48865SP
Q37MR16/HIR/CG25 37MR16/IR/NFL25/C 35MRC16/IRC/NFL24 48865FL
Q37MR16/HIR/CG40 37MR16/IR/FL40/C 35MRC16/IRC/FL36 48865WFL
--- 37MR16/IR/WFL60/C 35MRC16/IRC/WFL60 48865VWFL
Q50MR16/HIR/CG10 50MR16/IR/SP10/C 45MRC16/IRC/SP8 48870SP
Q50MR16/HIR/CG25 50MR16/IR/NFL25/C 45MRC16/IRC/NFL24 48870FL
For more complete product information visit www.sylvania.com 277
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
HALOGEN LAMPS
|
|
GE SYLVANIA PHILIPS OSRAM
|
TRU-AIM IR MR16 (continued)
Q50MR16/HIR/CG40 50MR16/IR/FL40/C 45MRC16/IRC/FL36 48870WFL
--- 50MR16/IR/WFL60/C 45MRC16/IRC/WFL60 48870VWFL
SINGLE ENDED
--- 100Q/CL/DC/64485 --- 64485
Q100CL/DC 100Q/CL/DC/ESR 100Q/CL/DC ESR ---
Q100CL/MC 100Q/CL/MC/ESN 100Q/CL ESN ---
Q100DC 100Q/DC/ETD --- ---
Q150CL/DC/2V 150Q/CL/DC/1/ESP --- ---
Q150CL/DC 150Q/CL/DC/ETC 150Q/CL/DC ETC ---
Q150CL/MC 150Q/CL/MC/2/ETG 150Q/CL ---
Q150CL/MC/2V 150Q/CL/MC/ESL --- ---
Q150DC 150Q/DC/ETF 150Q/DC ---
Q150MC 150Q/MC/ETH 150Q ETH ---
Q250CL/DC 250Q/CL/DC/ESS 250Q/CL/DC ESS ---
Q250CL/MC 250Q/CL/MC/EHT 250Q/CL EHT ---
Q250DC 250Q/DC/ETB --- ---
Q250MC 250Q/MC/ESM --- ---
DOUBLE ENDED
Q100T3/CL/CD 100T3Q/CL BC100T3Q/CL/TP ---
Q150T4/CL 150T3Q/S/CL BC150T3Q/CL/TP ---
Q150T3/117/CL/CD 150T3Q/CL --- ---
Q300T3/CL 300T3Q/CL 300T3Q/P/CL ---
Q500T3/CL 500T3Q/CL 500T3Q/P/CL ---
BIPIN
Q5T3/CL 5T3Q/CL 5W/12V/CAPSULE 64405S
Q10T3/CL 10T3Q/CL --- 64415
Q20T3/CL/CD 20T3Q/CL --- 64425
Q50T3/CL 50T4Q/CL 50W/12V/CAPSULE 64440
Q75T4/CL/CD 75T4Q/CL/RP --- ---
--- 10T3Q/CL/AX 10W/12V/CAPSULE 64415S
--- 20T3Q/CL/AX 20W/12V/CAPSULE 64425S
Q35T3/CL 35T4Q/CL/AX 35W/12V/CAPSULE 64432S
--- 50T4Q/CL/AX --- 64440S
--- 75T4Q/CL/AX --- 64450S
--- 90T4Q/CL/AX --- 64458S
AR 70 & AR111
--- 20AR70/SP8 15ALR18/NSP6-GBA 41970 SP USA
--- 20AR70/FL25 --- 41970 FL USA
--- 50AR70/SP8 50ALR18/SP10-GBJ 41990 SP USA
--- 50AR70/FL25 50ALR18/NFL22-GBK 41990 FL USA
--- 35AR111/SSP4 --- 41830 SSP
--- 50AR111SSP4 --- 41835 NSP 12V 50W
--- 50AR111/SP8 --- 41835 SP 12V 50W
--- 50AR111/FL25 --- 41835 FL 12V 50W
--- 75AR111/SP8 --- 41840 SP 12V 75W
--- 75AR111/FL25 --- 41840 FL 12V 75W
--- 75AR111/WFL45 --- 41840 WFL 12V 75W
--- 100AR111/SP8 --- 41850 SP 12V 100W
--- 100AR111/FL25 --- 41850 FL 12V 100W
--- 100AR111/WFL45 --- 41850 WFL 12V 100W
For more complete product information visit www.sylvania.com
278
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
HIGH INTENSITY DISCHARGE LAMPS - METAL HALIDE
|
|
GE SYLVANIA PHILIPS
|
METALARC CERAMIC
CMH39/TC/U/830/G8.5 MC39TC/U/G8.5/830 CDM35/TC/830
CMH70/TC/U/830/G8.5 MC70TC/U/G8.5/830 CDM70/TC/830
CMH39/T/U/830/G12 MC39T6/U/G12/830 CDM35/T6/830
CMH70UT830G12 MC70T6/U/G12/830 CDM70/T6/830
CMH150TU830G12 MC150T7.5/U/G12/830 CDM150/T6/830
CMH70TU942G12 MC70T6/U/G12/940 CDM70T6942
CMH150TU942G12 MC150T6/U/G12/940 CDM150T6942
CMH70/TD/830/RX7S MC70T6/DE/830 CDM70/TD/830
CMH150/TD/830/RX7S MC150T7.5/DE/830 CDM150/TD/830
CMH70/U/830/MED MCP70/U/MED/830 MHC70/U/MP/3K/ALTO
CMH70/C/U/830/MED MCP70/C/U/MED/830 MHC70/C/U/MP/3K/ALTO
CMH100/U/830/MED MCP100/U/MED/830 MHC100/U/MP/3K/ALTO
CMH100/C/U/830/MED MCP100/C/U/MED/830 MHC100/C/U/MP/3K/ALTO
--- MCP150/U/MED/830 MHC150/U/MP/3K/ALTO
--- MCP150/C/U/MED/830 MHC150/C/U/MP/3K/ALTO
CMH39/PAR20/SP10 MCP39PAR20/U/830/SP CDM35/PAR20/M/SP
CMH39/PAR20/FL25 MCP39PAR20/U/830/FL CDM35PAR20MFL
CMH39/PAR30L/830/SP10 MCP39PAR30LN/U/830/SP CDM35/PAR30L/M/SP
CMH39/PAR30L/830/FL25 MCP39PAR30LN/U/830/FL CDM35/PAR30L/M/FL
CMH70/U/PAR30L/830SP MCP70PAR30LN/U/830/SP CDMP70/PAR30L/M/SP
CMH70/U/PAR30L/830FL MCP70PAR30LN/U/830/FL CDM70/PAR30L/M/FL
CMH70/PAR38/830SP15 MCP70PAR38/U/SP/830/ECO CDM70/PAR38/SP/3K
CMH70/PAR38/830/FL25 MCP70PAR38/U/FL/830/ECO CDM70/PAR38/FL/3K
CMH70/PAR38/830/WF MCP70PAR38/U/VWFL/830/ECO CDM70/PAR38/WFL/3K
CMH100/PAR38/830/S15 MCP100PAR38/U/SP/830/ECO CDM100/PAR38/SP/3K
CMH100/PAR38/830/F25 MCP100PAR38/U/FL/830/ECO CDM100/PAR38/FL/3K
CMH100/PAR38/830/W MCP100PAR38/U/VWFL/830/ECO CDM100/PAR38/WFL/3K
--- MCP150PAR38/U/SP/830/ECO ---
--- MCP150PAR38/U/FL/830/ECO ---
--- MCP150PAR38/U/VWFL/830/ECO ---
--- MCP250/PS/BU-ONLY/940 ---
--- MCP250/C/PS/BU-ONLY/940 ---
METALARC PULSE START
MXR50/U/MED/O MP50/U/MED ---
MXR50/C/U/MED/O MP50/C/U/MED ---
MXR70/U/MED/O MP70/U/MED ---
MXR70/C/U/MED/O MP70/C/U/MED ---
MXR100/U/MED/O MP100/U/MED ---
MXR100/C/U/MED/O MP100/C/U/MED ---
MXR150/U/MED/O MP150/U/MED ---
MXR150/C/U/MED/O MP150/C/U/MED ---
MVR175CVBUMEDPA MS175/C/PS/BU-ONLY/MED ---
MVR175VBUVBUPA MS175/PS/BU-ONLY/MED ---
MVR175/VBU/PA MS175/PS/BU-ONLY MS175/BU/PS
MVR175/C/VBU/PA MS175/C/PS/BU-ONLY ---
--- MS200/PS/BU-ONLY ---
--- MS200/C/PS/BU-ONLY ---
MVR250/VBU/PA MS250/PS/BU-ONLY MS250/BU/PS
MVR250/C/VBU/PA MS250/C/PS/BU-ONLY ---
--- MP250/PS/BU-ONLY ---
--- MP250/C/PS/BU-ONLY ---
MVR320VBU/XHO/PA MS320/PS/BU-HOR MS320/U/PS
MVR320/VBU/HO/PA MS320/PS/BU-HOR MS320/U/PS
MVR320/C/VBU/XHOPA MS320/C/PS/BU-HOR MS320/C/U/PS
MVR320/C/VBU/HOPA MS320/C/PS/BU-HOR MS320/C/U/PS
MPR320/C/VBUXHOPA MP320/350/C/PS/BU-ONLY/BT28 ---
MPR350/C/VBU/PA MP320/350/C/PS/BU-ONLY/BT28 ---
MPR320/VBU/XHOPA MP320/350/PS/BU-ONLY/BT28 ---
MPR400/VBU/SHO/PA MP350/400/PS/BU-ONLY MP400/BU/PS
MPR400/C/VBU/XHOPA MP350/400/C/PS/BU-ONLY MP400/C/BU/PS
MPR350C/VBU/PA MP350/400/C/PS/BU-ONLY MP400/C/BU/PS
For more complete product information visit www.sylvania.com 279
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
HIGH INTENSITY DISCHARGE LAMPS - METAL HALIDE
|
|
GE SYLVANIA PHILIPS
|
METALARC PULSE START (continued)
MVR400VBUHOPA MS400/PS/BU-ONLY MS400/BU/PS
MVR400/C/VBU/PA MS400/C/PS/BU-ONLY MS400/C/BU/PS
MVR400CVBUHOPA MS400/C/PS/BU-ONLY MS400/C/BU/PS
MVR750/VBU/PA MS750/PS/BU-HOR/BT37 ---
MVR750/C/VBU/PA MS750/C/PS/BU-HOR/BT37 ---
--- M1000/PS/U/BT37 MS1000/BU/BT37/PS
METALARC SUPER SAVER
MVR150/U/WM M150/SS/U/BT-28 ---
MVR360/VBU/STB/WM MS360/SS/BU-HOR MS360/BU/EW
MVR360/C/VBU/STB/WM MS360/C/SS/BU-HOR MS360/C/BU/EW
MPR360/VBU/WM/O MSP360/SS/BU-ONLY MP360BU/EW
--- MS360/SS/BU-ONLY/ED28 ---
METALARC SUPER
MVR175/HOR MS175/HOR MS175/HOR
MVR175/C/HOR MS175/C/HOR MS175/C/HOR
MVR250/HOR MS250/HOR MS250/HOR
MVR250/C/HOR MS250/C/HOR MS250/C/HOR
MVR400/VBU MS400/BU-ONLY MS400/BU
MVR400/C/VBU MS400/C/BU-ONLY MS400/C/BU
MVR400/SP30/VBU MS400/3K/BU-ONLY MS400/3K/BU
MVR400/VBU/BT28 MS400/BU-ONLY/BT28 MS400/BU/ED28
MVR400/HOR/BT28 MS400/HOR/BT28 MH400/U/ED28
MVR400/HOR/MOG MS400/HOR MS400/HOR
MVR400/C/HOR/MOG MS400/C/HOR MS400/C/HOR
MVR1000/VBU MS1000/BU-ONLY MS1000/BU
MVR1000/C/VBU MS1000/C/BU-ONLY MS1000/C/BU
--- MS1000/BD-ONLY MS1000/BD
METALARC STANDARD &
METALARC PRO-TECH
MVR175/U/MED M175/U/MED MH175/U/M
MVR175/C/U/MED M175/C/U/MED MH175/C/U/M
MVR175/U M175/U MH175/U
MVR175/C/U M175/C/U MH175/C/U
--- MP175/BU-ONLY MP175/BU
MVR175/SP30/U M175/3K/BU-ONLY MH175/3K/BU
MVR250/U M250/U MH250/U
MVR250/C/U M250/C/U MH250/C/U
--- M250/U/ET18 MH250/T15
MVR250/SP30/U M250/3K/BU-ONLY MH250/3K/BU
--- MP250/BU-ONLY MP250/BU
MVR400/U M400/U MH400/U
MVR400/C/U M400/C/U MH400/C/U
MVR400/U/ED28 M400/U/BT28 MH400/U/ED28
MVR400/C/U/ED28 M400/C/U/BT28 ---
--- M400/U/ET18 MH400/T15
MPR400/VBU/O MP400/BU-ONLY MP400/BU
MPR400/C/VBU/O MP400/C/BU-ONLY MP400/C/BU
MVR1000/U M1000/U MH1000/U
MVR1000/C/U M1000/C/U MH1000/C/U
MVR1000/U/BT37 M1000/U/BT37 MH1000/U/BT37
MPR1000VBUO MP1000/BU-ONLY MP1000/BU
MVR1500/HBU M1500/BU-HOR MH1500/BU
MVR1500/U/SPORTS M1500/BD MH1500/BD
METALARC BRITELINE
SPL1500/L/H/652 M1500T7/DE ---
MQI2000/T9/40 M2000T9/DE ---
METALARC SAFELINE
MVT400/VBU MT400/BU-ONLY MHT400/U
MVT400/C/VBU MT400/C/BU-ONLY MHT400/C/U
For more complete product information visit www.sylvania.com
280
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
HIGH INTENSITY DISCHARGE LAMPS - HIGH PRESSURE SODIUM
|
|
GE SYLVANIA PHILIPS
|
DOUBLE-ENDED HQI
ARC70TDUVC730 HQI-DE70/WDX ---
ARC70TDUVC743 HQI-DE70/NDX MHN70/TD/840
ARC150TDUVC742 HQI-DE150/NDX MHN150/TD/840
SINGLE-ENDED HQI
ARC150/T/U/840/G12 HQI-SE 150/NDX ---
LUMALUX PLUS / ECO
--- LU50/PLUS/ECO ---
LU70/ECO/NC LU70/PLUS/ECO ---
LU100/ECO/NC LU100/PLUS/ECO ---
LU150/ECO/NC LU150/55/PLUS/ECO ---
LU200/ECO/NC LU200/PLUS/ECO ---
LU250/EC0/NC LU250/PLUS/ECO ---
--- LU310/PLUS/ECO ---
LU400/EC0/NC LU400/PLUS/ECO ---
LUMALUX STANDARD & ECOLOGIC
LU35/MED LU35/MED C35S76/M
LU35/D/MED LU35/D/MED C35S76/D/M
LU50/MED LU50/MED C50S68/M
LU50/D/MED LU50/D/MED C50S68/D/M
LU50 LU50/ECO C50S68/ALTO
LU50/D LU50/D C50S68/D/ALTO
LU70/MED LU70/MED C70S62/M
LU70/D/MED LU70/D/MED C70S62/D/M
LU70ECO LU70/ECO C70S62/ALTO
LU70/D LU70/D C70S62/D/ALTO
LU100/MED LU100/MED C100S54/M
LU100/D/MED LU100/D/MED C100S54/D/M
LU100ECO LU100/ECO C100S54/ALTO
LU100/D LU100/D C100S54/D/ALTO
LU150/MED LU150/55/MED C150S55/M
LU150/D/MED LU150/55/D/MED C150S55/D/M
LU150/55/ECO LU150/55/ECO C150S55/ALTO
LU150/55/D LU150/55/D C150S55/D/ALTO
LU150/100 LU150/100 C150S56
LU200/ECO LU200/ECO C200S66/ALTO
LU250/ECO LU250/ECO C250S50/ALTO
LU250/D LU250/D C250S50/D/ALTO
LU310 LU310/ECO C310S67
LU400/D LU400/D C400S51/D/ALTO
LU400/ECO LU400/ECO C400S51/ALTO
LU750 LU750 ---
LU1000 LU1000 C1000S52/ALTO
LUMALUX STANDBY
LU70/SBY/XL LU70/SBY C70S62/2
LU100/SBY/XL LU100/SBY C100S54/2
LU150/55/SBY/XL LU150/55/SBY C150S55/2
LU250/SBY/XL LU250/SBY C250S50/2
LU200/SBY/XL LU200/100/SBY ---
LU400/SBY/XL LU400/SBY C400S51/2
LU1000/SBY/XL LU1000/SBY C1000S52/2
UNALUX
LUH150/EZ ULX150 C150S63/Retrolux
LUH215/EZ ULX215 C215S65/Retrolux
LUH360/EZ ULX360 C360S64/Retrolux
For more complete product information visit www.sylvania.com 281
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
HIGH INTENSITY DISCHARGE LAMPS - LOW PRESSURE SODIUM
|
|
GE SYLVANIA PHILIPS
|
SOX LOW PRESSURE SODIUM
SOX-18 SOX18 SOX-E18
SOX-55 SOX55 SOX55
SOX-90 SOX90 SOX99
--- SOX180 SOX180
HIGH INTENSITY DISCHARGE LAMPS - MERCURY
|
|
GE SYLVANIA PHILIPS
|
STANDARD MERCURY VAPOR
HR40/50DX45-46 H45/46DL-40/50/DX H46DL-40-50/DX
HR75DX43 H43AV-75/DX H43AV-75/DX
HR100DX38/MED H38AV-100/DX H38MP-100/DX
HR100RDXFL38 H38BP-100/DX H38BP-100/DX
HR100A38 H38HT-100 H38HT-100
HR100DX38 H38JA-100/DX H38JA-100/DX
HR175RFL39 H39BP-175/DX H39BM-175
HR175A39 H39KB-175 H39KB-175
HR175DX39 H39KC-175/DX H39KC-175/DX
HR250A37 H37KB-250 H37KB-250
HR250DX37 H37KC-250/DX H37KC-250/DX
HR400A33 H33CD-400 H33CD-400
HR400DX33 H33GL-400/DX H33GL-400/DX
HR1000A36 H36GV-1000 H36GV-1000
HR1000DX36 H36GW-1000/DX H36GW-1000/DX
HR1000DX34 H34GW-1000/DX H34GW-1000/DX
MERCURY VAPOR SAFELINE
HT400DX33 H33GL-T400/DX H33GL-T400/DX
For more complete product information visit www.sylvania.com
282
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
OCTRON
F17T8/SPX30/ECO FO17/830/ECO F17T8/TL830
F17T8/SPX35/ECO FO17/835/ECO F17T8/TL835
F17T8/SPX41/ECO FO17/841/ECO F17T8/TL841
--- FO17/830/XP/ECO ---
--- FO17/835/XP/ECO ---
--- FO17/841/XP/ECO ---
--- FO17/865/XP/ECO F17T8/TL865 PLUS
--- FO17/830XPS/ECO ---
--- FO17/835XPS/ECO ---
--- FO17/841XPS/ECO ---
F25T8/SPX30/ECO FO25/830/ECO F25T8/TL830
F25T8/SPX35/ECO FO25/835/ECO F25T8/TL835
F25T8/SPX41/ECO FO25/841/ECO F25T8/TL841
--- FO25/830/XP/ECO ---
--- FO25/835/XP/ECO ---
--- FO25/841/XP/ECO ---
--- FO25/865/XP/ECO F25T8/TL865 PLUS
--- FO25/830XPS/ECO ---
--- FO25/835XPS/ECO ---
--- FO25/841XPS/ECO ---
F28T8SP30UMX/ECO FO28/830XP/SS/ECO ---
F28T8SP35UMX/ECO FO28/835XP/SS/ECO ---
F28T8SP41UMX/ECO FO28/841XP/SS/ECO ---
F32T8XL/SP30/IS/WM/ECO FO30/830XP/SS/ECO F32T8/ADV830/EW/ALTO
F32T8XL/SP35/IS/WM/ECO FO30/835XP/SS/ECO F32T8/ADV835/EW/ALTO
F32T8XL/SP41/IS/WM/ECO FO30/841XP/SS/ECO F32T8/ADV841/EW/ALTO
F32T8/SP30/ECO FO32/730/ECO F32T8/TL730/ALTO
F32T8/SP35/ECO FO32/735/ECO F32T8/TL735/ALTO
F32T8/SP41/ECO FO32/741/ECO F32T8/TL741/ALTO
F32T8/SP50/ECO FO32/750/ECO F32T8/TL750/ALTO
F32T8/SP65/ECO FO32/765/ECO ---
F32T8/XL/SP30/ECO FO32/730/XP/ECO F32T8/TL730 PLUS/ALTO
F32T8/XL/SP35/ECO FO32/735/XP/ECO F32T8/TL735 PLUS/ALTO
F32T8/XL/SP41/ECO FO32/741/XP/ECO F32T8/TL741 PLUS/ALTO
--- FO32/750/XP/ECO F32T8/TL750 PLUS/ALTO
F32T8/SPX30/ECO FO32/830/ECO F32T8/TL830/ALTO
F32T8/SPX35/ECO FO32/835/ECO F32T8/TL835/ALTO
F32T8/SPX41/ECO FO32/841/ECO F32T8/TL841/ALTO
F32T8/SPX50/ECO FO32/850/ECO F32T8/TL850/ALTO
--- FO32/827/XP/ECO ---
F32T8/XL/SPX30/ECO FO32/830/XP/ECO F32T8/TL830 PLUS/ALTO
F32T8/XL/SPX35/ECO FO32/835/XP/ECO F32T8/TL835 PLUS/ALTO
F32T8/XL/SPX41/ECO FO32/841/XP/ECO F32T8/TL841 PLUS/ALTO
F32T8/XL/SPX50/ECO FO32/850/XP/ECO F32T8/TL850 PLUS/ALTO
F32T8/XL/SPX65/ECO FO32/865/XP/ECO F32T8/TL865 PLUS/ALTO
F32T8SXL/SPX30/ECO --- ---
F32T8SXL/SPX35/ECO --- ---
F32T8SXL/SPX41/ECO --- ---
F32T8/XL/SPX30/HLEC FO32/830XPS/ECO F32T8/ADV830/ALTO
F32T8/XL/SPX35/HLEC FO32/835XPS/ECO F32T8/ADV835/ALTO
F32T8/XL/SPX41/HLEC FO32/841XPS/ECO F32T8/ADV841/ALTO
F40T8/SPX30 FO40/830/ECO F40T8/TL830/ALTO
F40T8/SPX35 FO40/835/ECO F40T8/TL835/ALTO
F40T8/SPX41 FO40/841/ECO F40T8/TL841/ALTO
--- FO40/830/XP/ECO ---
--- FO40/835/XP/ECO ---
--- FO40/841/XP/ECO ---
F96T8/XL/SP30/WM FO96/830XP/SS/ECO ---
F96T8/XL/SP35/WM FO96/835XP/SS/ECO ---
F96T8/XL/SP41/WM FO96/841XP/SS/ECO ---
F96T8/SPX30 FO96/830/ECO F96T8/TL830
For more complete product information visit www.sylvania.com 283
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
OCTRON (continued)
F96T8/SPX35 FO96/835/ECO F96T8/TL835
F96T8/SPX41 FO96/841/ECO F96T8/TL841
F96T8/SPX50 FO96/850/ECO F96T8/TL850
F96T8/XL/SPX30 FO96/830/XP/ECO F96T8/TL830PLUS/ALTO
F96T8/XL/SPX35 FO96/835/XP/ECO F96T8/TL835PLUS/ALTO
F96T8/XL/SPX41 FO96/841/XP/ECO F96T8/TL841PLUS/ALTO
F96T8/XL/SPX50 FO96/850/XP/ECO F96T8/TL850PLUS/ALTO
F96T8/SPX30/HO --- F96T8/TL830/HO
F96T8/SPX35/HO FO96/835/HO F96T8/TL835/HO
F96T8/SPX41/HO FO96/841/HO F96T8/TL841/HO
OCTRON CURVALUME
--- FBO16/830 ---
--- FBO16/835 ---
--- FBO16/841 ---
--- FBO16/865/XP ---
--- FBO24/830 ---
--- FBO24/835 ---
--- FBO24/841 ---
F31T8/SPX30/U FBO31/830 ---
F31T8/SPX35/U FBO31/835 ---
F31T8/SPX41/U FBO31/841 ---
--- FBO31/830/XP/ECO ---
--- FBO31/835/XP/ECO ---
--- FBO31/841/XP/ECO ---
--- FBO30/830/XP/SS/ECO ---
--- FBO30/835/XP/SS/ECO ---
--- FBO30/841/XP/SS/ECO ---
F32T8/SPX30/U/6 FBO32/830/6/ECO FB32T8/830/6/ALTO
F32T8/SPX35/U/6 FBO32/835/6/ECO FB32T8/835/6/ALTO
F32T8/SPX41/U/6 FBO32/841/6/ECO FB32T8/841/6/ALTO
--- FBO32/830/6/XP/ECO ---
--- FBO32/835/6/XP/ECO ---
--- FBO32/841/6/XP/ECO ---
PENTRON & PENTRON HO
F14/T5/830 FP14/830/ECO F14T5/830
F14/T5/835 FP14/835/ECO F14T5/835
F14/T5/841 FP14/841/ECO F14T5/841
F21/T5/830 FP21/830/ECO F21T5/830
F21/T5/835 FP21/835/ECO F21T5/835
F21/T5/841 FP21/841/ECO F21T5/841
F28/T5/830 FP28/830/ECO F28T5/830
F28/T5/835 FP28/835/ECO F28T5/835
F28/T5/841 FP28/841/ECO F28T5/841
F35/T5/830 FP35/830/ECO F35T5/830
F35/T5/835 FP35/835/ECO F35T5/835
F35/T5/841 FP35/841/ECO F35T5/841
F24/T5/830/HO FP24/830/HO/ECO F24T5/830/HO/ALTO
F24/T5/835/HO FP24/835/HO/ECO F24T5/835/HO
F24/T5/841/HO FP24/841/HO/ECO F24T5/841/HO
F39/T5/830/HO FP39/830/HO/ECO F39T5/830/HO
F39/T5/835/HO FP39/835/HO/ECO F39T5/835/HO
F39/T5/841/HO FP39/841/HO/ECO F39T5/841/HO
F54/T5/830/HO FP54/830/HO/ECO F54T5/830/HO/ALTO
F54/T5/835/HO FP54/835/HO/ECO F54T5/835/HO/ALTO
F54/T5/841/HO FP54/841/HO/ECO F54T5/841/HO/ALTO
F80/T5/830/HO FP80/830/HO/ECO F80T5/830/HO
F80/T5/835/HO FP80/835/HO/ECO ---
F80/T5/841/HO FP80/841/HO/ECO F80T5/841/HO
PENTRON CIRCLINE
--- FPC22/830 FC9T5/830
--- FPC22/835 FC9T5/835
For more complete product information visit www.sylvania.com
284
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
PENTRON CIRCLINE (continued)
--- FPC22/841 FC9T5/841
--- FPC40/830 FC12T5/830
--- FPC40/835 FC12T5/835
--- FPC40/841 FC12T5/841
--- FPC55/830/HO ---
--- FPC55/835/HO ---
--- FPC55/841/HO ---
F40 TYPES (STD & SS)
F34/SP30/RS/WM/ECO F34/D30/SS/ECO F34/SPEC30/RS/EW/ALTO
F34/SP35/RS/WM/ECO F34/D35/SS/ECO F34/SPEC35/RS/EW/ALTO
F34/SP41/RS/WM/ECO F34/D41/SS/ECO F34/SPEC41/RS/EW/ALTO
F34/SPX30/RS/WM/ECO F34/D830/SS/ECO F34/30U/RS/EW/ALTO
F34/SPX35/RS/WM/ECO F34/D835/SS/ECO F34/35URS/EW/ALTO
F34/SPX41/RS/WM/ECO F34/D841/SS/ECO F34/41U/RS/EW/ALTO
F40/SP30/RS/ECO F40/D30/ECO F40/SPEC30/RS/ALTO
F40/SP35/RS/ECO F40/D35/ECO F40/SPEC35/RS/ALTO
F40/SP41/RS/ECO F40/D41/ECO F40/SPEC41/RS/ALTO
F40/SPX30/RS/ECO F40/D830/ECO F40/30U/RS/ALTO
F40/SPX35/RS/ECO F40/D835/ECO F40/35URS/ALTO
F40/SPX41/RS/ECO F40/D841/ECO F40/41U/RS/ALTO
F40/XL/SP30, 35, 41 --- ---
F40/XL/SPX30, 35, 41 --- ---
CURVALUME®3"
F40/SP30/U/3 --- ---
F40/SP41/U/3 --- ---
CURVALUME®6"
--- FB34/D30/6/SS FB34/SPEC30/6/EW/ALTO
--- FB34/D35/6/SS FB34/SPEC35/6/EW/ALTO
--- FB34/D41/6/SS FB34/SPEC41/6/EW/ALTO
F40/SP30/U/6 FB40/D30/6 FB40/SPEC30/6/ALTO
F40/SP35/U/6 FB40/D30/6 FB40/SPEC35/6/ALTO
F40/SP41/U/6 FB40/D41/6 FB40/SPEC41/6/ALTO
F40/SPX30/U/6 FB40/D830/6 FB40/30U/6/ALTO
F40/SPX35/U/6 --- FB40/35U/6/ALTO
--- --- FB40/41U/6/ALTO
SLIMLINE
F96T12/SP35/WMP --- ---
F96T12/SP30/WM/ECO F96T12/D30/SS/ECO F96T12/SPEC30/EW/ALTO
F96T12/SP35/WM/ECO F96T12/D35/SS/ECO F96T12/SPEC35/EW/ALTO
F96T12/SP41/WM/ECO F96T12/D41/SS/ECO F96T12/SPEC41/EW/ALTO
F96T12/SPX30/WM/ECO F96T12/D830/SS/ECO F96T12/30U/EW/ALTO
F96T12/SPX35/WM/ECO F96T12/D835/SS/ECO F96T12/35U/EW/ALTO
F96T12/SPX41/WM/ECO F96T12/D841/SS/ECO F96T12/41U/EW/ALTO
F96T12/XL/SP35/WM --- ---
F96T12/XL/SP41/WM --- ---
F96T12/SP30/ECO F96T12/D30/ECO F96T12/SPEC30/ALTO
F96T12/SP35/ECO F96T12/D35/ECO F96T12/SPEC35/ALTO
F96T12/SP41/ECO F96T12/D41/ECO F96T12/SPEC41/ALTO
F96T12/SPX30/ECO F96T12/D830/ECO F96T12/30U/ALTO
F96T12/SPX35/ECO F96T12/D835/ECO F96T12/35U/ALTO
F96T12/SPX41/ECO F96T12/D841/ECO F96T12/41U/ALTO
F96T12/XL/SP35, 41 --- ----
F96T12/XL/SPX35, 41, 50 --- ---
HIGH OUTPUT
F72T12/SPX30/HO F72T12/D830/HO F72T12/30U/HO
--- --- F96T12/SPEC30/HO/EW
F96T12/SP35/HO/WM F96T12/D35/HO/SS F96T12/SPEC35/HO/EW
F96T12/SP41/HO/WM F96T12/D41/HO/SS F96T12/SPEC41/HO/EW
F96T12/SPX830/HO/WM F96T12/D830/HO/SS F96T12/30U/HO/EW
F96T12/SPX35/HO/WM F96T12/D835/HO/SS F96T12/35U/HO/EW
F96T12/SPX41/HO/WM F96T12/D841/HO/SS F96T12/41U/HO/EW
For more complete product information visit www.sylvania.com 285
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
HIGH OUTPUT (continued)
F96T12/SP30/HO F96T12/D30/HO F96T12/SPEC30/HO
F96T12/SP35/HO F96T12/D35/HO F96T12/SPEC35/HO
F96T12/SP41/HO F96T12/D41/HO F96T12/SPEC41/HO
F96T12/SPX830/HO F96T12/D830/HO F96T12/30U/HO
F96T12/SPX35/HO F96T12/D835/HO F96T12/35U/HO
F96T12/SPX41/HO F96T12/D841/HO F96T12/41U/HO
APPLIANCE
F24"T8/CW/4 F18T8CW/K24 F15T8/CW/24
F26"T8/CW/4 F18T8CW/K26 F16T8/CW/26
F28"T8/CW/4 F18T8CW/K28 F17T8/CW/28
F30"T8/CW/4 F18T8CW/K30 F18T8/CW/30
--- F18T8/D/K26 ---
OTHER RAPID START
F25T12/SP30/RS/WM F25T12/D30/RS/SS ---
F25T12/SP35/RS/WM F25T12/D35/RS/SS ---
F30T12/SP35/RS F30T12/D35/RS F30T12/SPEC35/RS
F30T12/SP41/RS F30T12/D41/RS F30T12/SPEC41/RS
F30T12/SPX30/RS F30T12/D830/RS F30T12/30U/RS
F30T12/SPX35/RS F30T12/D835/RS F30T12/35U/RS
For more complete product information visit www.sylvania.com
286
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
COMPACT FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
DULUX S - 2 PIN
F5BX/SPX27/827 CF5DS/827 (ECO) PL-S 5W/827
F5BX/SPX41/840 CF5DS/841 (ECO) ---
F7BX/SPX27/827 CF7DS/827 (ECO) PL-S 7W/827
F7BX/SPX35/835 CF7DS/835 (ECO) PL-S 7W/835
F7BX/SPX41/840 CF7DS/841 (ECO) PL-S 7W/841
F7BX/SPX50/850 CF7DS/850 (ECO) PL-S 7W/850
F9BX/SPX27/827 CF9DS/827 (ECO) PL-S 9W/827
F9BX/SPX35/835 CF9DS/835 (ECO) PL-S 9W/835
F9BX/SPX41/840 CF9DS/841 (ECO) PL-S 9W/841
F9BX/SPX50 CF9DS/850 (ECO) PL-S 9W/850
--- CF9DS/BLUE ---
--- CF9DS/GREEN ---
--- CF9DS/RED ---
F13BX/SPX27/827 CF13DS/827 (ECO) PL-S 13W/827
F13BX/SPX30/830 CF13DS/830 (ECO) PL-S 13W/830
F13BX/SPX35/835 CF13DS/835 (ECO) PL-S 13W/835
F13BX/SPX41/84 CF13DS/841 (ECO) PL-S 13W/841
F13BX/SPX50 CF13DS/850 (ECO) PL-S 13W/850
F13BX/E/830, 835, 841, 850 CFT13/DS/EC/827, 835, 841 ---
F13BX/BLUE --- ---
F13BX/GREEN CF13DS/GREEN ---
DULUX S/E - 4 PIN
--- CF5DS/E/827 ---
--- CF5DS/E/841 ---
--- CF7DS/E/827 ---
--- CF7DS/E/841 ---
--- CF9DS/E/827 ---
--- CF9DS/E/841 ---
--- CF13DS/E/827 ---
--- CF13DS/E/830 ---
--- CF13DS/E/841 ---
DULUX D - 2 PIN
F9DBX23T4/SPX27/827 CF9DD/827 (ECO) ---
--- CF9DD/830 (ECO) ---
--- CF9DD/835 (ECO) ---
F9DBX23T4/SPX41 --- ---
F13DBX23T4/SPX27 CF13DD/827 (ECO) PL-C 13W/827/USA/ALTO
F13DBXT4/SPX27 (G24d-1) --- PL-C 13W/827/ALTO (G24d-1)
F13DBX23T4/SPX30 CF13DD/830 (ECO) PL-C 13W/830/USA/ALTO
F13DBXT4/SPX30 (G24d-1) --- PL-C 13W/830/ALTO (G24d-1)
F13DBX23T4/SPX35 CF13DD/835 (ECO) PL-C 13W/835/USA/ALTO
F13DBXT4/SPX35 (G24d-1) --- ---
F13DBX23T4/SPX41 CF13DD/841 (ECO) PL-C 13W/841/USAALTO
F13DBXT4/SPX41 (G24d-1) --- ---
F18DBXT4/SPX27 CF18DD/827 (ECO) PL-C 18W/827/ALTO
F18DBXT4/SPX30 CF18DD/830 (ECO) PL-C 18W/830/ALTO
F18DBXT4/SPX35 CF18DD/835 (ECO) PL-C 18W/835/ALTO
F18DBXT4/SPX41 CF18DD/841 (ECO) PL-C 18W/841/ALTO
--- --- PL-C 15mm/22W/827
F26DBXT4/SPX27 CF26DD/827 (ECO) PL-C 26W/827/ALTO
F26DBXT4/SPX30 CF26DD/830 (ECO) PL-C 26W/830/ALTO
F26DBXT4/SPX35 CF26DD/835 (ECO) PL-C 26W/835/ALTO
F26DBXT4/SPX41 CF26DD/841 (ECO) PL-C 26W/841/ALTO
F26DBXT4/E/827 --- ---
F26DBXT4/E/830 --- ---
F26DBXT4/E/835 --- ---
F26DBXT4/E/841 --- ---
DULUX D/E - 4 PIN
--- --- PL-C 15mm/28W/827
F13DBX/SPX27/4P CF13DD/E/827 (ECO) PL-C 13W/827/4P/ALTO
F13DBX/SPX30/4P CF13DD/E/830 (ECO) PL-C 13W/830/4P/ALTO
For more complete product information visit www.sylvania.com 287
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
COMPACT FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
DULUX D/E - 4 PIN (continued)
F13DBX/SPX35/4P CF13DD/E/835 (ECO) PL-C 13W/835/4P/ALTO
F13DBX/SPX41/4P CF13DD/E/841 (ECO) PL-C 13W/841/4P/ALTO
F18DBX/SPX27/4PL CF18DD/E/827 (ECO) PL-C 18W/827/4P/ALTO
F18DBX/SPX30/4PL CF18DD/E/830 (ECO) PL-C 18W/830/4P/ALTO
F18DBX/SPX35/4PL CF18DD/E/835 (ECO) PL-C 18W/835/4P/ALTO
F18DBX/SPX41/4PL CF18DD/E/841 (ECO) PL-C 18W/841/4P/ALTO
F26DBXT4/SPX27/4P CF26DD/E/827 (ECO) PL-C 26W/827/4P/ALTO
F26DBXT4/SPX30/4P CF26DD/E/830 (ECO) PL-C 26W/830/4P/ALTO
F26DBX/SPX35/4P CF26DD/E/835 (ECO) PL-C 26W/835/4P/ALTO
F26DBX/SPX41/4P CF26DD/E/841 (ECO) PL-C 26W/841/4P/ALTO
DULUX T - 2 PIN
--- CF18DT/827 (ECO) ---
--- CF26DT/827 (ECO) ---
DULUX T/E - 4 PIN (NON-AMALGAM)
--- CF13DT/E/827 (ECO) ---
--- CF13DT/E/830 (ECO) ---
--- CF13DT/E/835 (ECO) ---
--- CF13DT/E/841 (ECO) ---
--- CF26DT/E/827 (ECO) ---
--- CF32DT/E/827 (ECO) ---
DULUX T/E/IN - 4 PIN (AMALGAM)
F13TBX/SPX27/A/4P --- ---
F13TBX/SPX30/A/4P --- ---
F13TBX/SPX35/A/4P --- ---
F13TBX/SPX41/A/4P --- ---
F18TBX/SPX27/A/4P CF18DT/E/IN/827 (ECO) PL-T 18W/827/4P/ALTO
F18TBX/SPX30/A/4P CF18DT/E/IN/830 (ECO) PL-T 18W/830/4P/ALTO
F18TBX/SPX35/A/4P CF18DT/E/IN/835 (ECO) PL-T 18W/835/4P/ALTO
F18TBX/SPX41/A/4P CF18DT/E/IN/841 (ECO) PL-T 18W/841/4P/ALTO
F26TBX/SPX27/A/4P CF26DT/E/IN/827 (ECO) PL-T 26W/827/4P/ALTO
F26TBX/SPX30/A/4P CF26DT/E/IN/830 (ECO) PL-T 26W/830/4P/ALTO
F26TBX/SPX35/A/4P CF26DT/E/IN/835 (ECO) PL-T 26W/835/4P/ALTO
F26TBX/SPX41/A/4P CF26DT/E/IN/841 (ECO) PL-T 26W/841/4P/ALTO
F32TBX/SPX27/A/4P CF32DT/E/IN/827 (ECO) PL-T 32W/827/4P/ALTO
F32TBX/SPX30/A/4P CF32DT/E/IN/830 (ECO) PL-T 32W/830/4P/ALTO
F32TBX/SPX35/A/4P CF32DT/E/IN/835 (ECO) PL-T 32W/835/4P/ALTO
F32TBX/SPX41/A/4P CF32DT/E/IN/841 (ECO) PL-T 32W/841/4P/ALTO
F42TBX/827/A/4P/EOL CF42DT/E/IN/827 (ECO) PL-T 42W/827/4P/ALTO
F42QBX/SPX27/A/4P --- F42QBX/SPX27/A/4P
F42TBX/830/A/4P/EOL CF42DT/E/IN/830 (ECO) PL-T 42W/830/4P/ALTO
F42QBX/SPX30/A/4P --- ---
F42TBX/835/A/4P/EOL CF42DT/E/IN/835 (ECO) PL-T 42W/835/4P/ALTO
F42QBX/SPX35/A/4P --- ---
F42TBX/841/A/4P/EOL CF42DT/E/IN/841 (ECO) PL-T 42W/841/4P/ALTO
F42QBX/SPX41/A/4P --- ---
--- CF57DT/E/IN/827 (ECO) ---
--- CF57DT/E/IN/830 (ECO) ---
F57QBX/830/A/4P/EOL --- ---
--- CF57DT/E/IN/835 (ECO) ---
F57QBX/835/A/4P/EOL --- ---
--- CF57DT/E/IN/841 (ECO) ---
F57QBX/841/A/4P/EOL --- ---
F57QBX/850/A/4P/EOL --- ---
DULUX L - 4 PIN
F18BX/SPX30 FT18DL/830 PL-L 18W/830
F18BX/SPX30/RS FT18DL/830/RS ---
F18BX/SPX35 FT18DL/835 PL-L 18W/835
F18BX/SPX35/RS FT18DL/835/RS ---
F18BX/SPX41 FT18DL/841 PL-L 18W/841
F18BX/SPX41/RS FT18DL/841/RS ---
F27BX/SPX30/RS FT24DL/830 PL-L 24W/830
For more complete product information visit www.sylvania.com
288
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
COMPACT FLUORESCENT LAMPS
|
|
GE SYLVANIA PHILIPS
|
DULUX L - 4 PIN (continued)
F27BX/SPX35/RS FT24DL/835 PL-L 24W/835
F27BX/SPX41/RS FT24DL/841 PL-L 24W/841
F39BX/SPX30/RS FT36DL/830 PL-L 36W/830
F39BX/SPX35/RS FT36DL/835 PL-L 36W/835
F39BX/SPX41/RS FT36DL/841 PL-L 36W/841
F40/30BX/SPX30 FT40DL/830/RS PL-L 40W/830/RS
F40/30BX/SPX35 FT40DL/835/RS PL-L 40W/835/RS
F40/30BX/SPX41 FT40DL/841/RS PL-L 40W/841/RS
F50BX/SPX30/RS --- PL-L 50W/830/RS
F50BX/SPX35/RS --- PL-L 50W/835/RS
F50BX/SPX41/RS --- PL-L 50W/841/RS
F55BX/830 FT55DL/830 ---
F55BX/835 FT55DL/835 ---
F55BX/841 FT55DL/841 ---
--- FT80DL/830 PL-L 80W/830
--- FT80DL/835 PL-L 80W/835
--- FT80DL/841 PL-L 80W/841
DULUX F - 4 PIN
--- CF18DF/830 ---
--- CF18DF/841 ---
--- CF24DF/830 ---
--- CF24DF/841 ---
--- CF36DF/830 ---
--- CF36DF/841 ---
For more complete product information visit www.sylvania.com 289
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
ELECTRONIC FLUORESCENT LAMP BALLASTS UNIVERSAL LIGHTING
|
TECHNOLOGIES HOWARD
|
ADVANCE SYLVANIA (formerly Magnetek)* INDUSTRIES
|
QUICKTRONIC®32 T8 INSTANT START
32 T8 Instant Start - Normal Ballast Factor - Small Can - <20% THD
REL-1P32-SC QT1x32T8/120ISN-SC B132I120RH-A E1/32IS-120SC
VEL-1P32-SC QT1x32T8/277ISN-SC B132I277RH-A E1/32IS-277SC
REL-2P32-SC QT2x32T8/120ISN-SC B232I120RH-A E2/32IS-120SC
VEL-2P32-SC QT2x32T8/277ISN-SC B232I277RH-A E2/32IS-277SC
REL-3P32-SC QT3x32T8/120ISN-SC B332I120RH-A E3/32IS-120SC
VEL-3P32-SC QT3x32T8/277ISN-SC B332I277RH-A E3/32IS-277SC
REL-4P32-SC QT4x32T8/120ISN-SC B432I120RH-A E4/32IS-120SC
VEL-4P32-SC QT4x32T8/277ISN-SC B432I277RH-A E4/32IS-277SC
GEL-2P32-SC QT2x32T8/347ISN-SC B232I347RH (F-Can) E2/32IS-347 (F-Can)
GEL-4P32-RH-TP (F-Can) QT4x32T8/347ISN-SC B432I347RH (F-Can) E4/32IS-347 (F-Can)
32 T8 Instant Start - Normal Ballast Factor - Standard “F” Can - <20% THD
REL-3P32-RH-TP QT3x32/120IS B332I120RH E3/32IS-120
VEL-3P32-RH-TP QT3x32/277IS B332I277RH E3/32IS-277
REL-4P32-RH-TP QT4x32/120IS B432I120RH E4/32IS-120
VEL-4P32-RH-TP QT4x32/277IS B432I277RH E4/32IS-277
GEL-3P32-RH-TP QT3x32/347IS B332I347RH E3/32IS-347
GEL-4P32-RH-TP QT4x32/347IS B432I347RH E4/32IS-347
32 T8 Instant Start - High Ballast Factor - “PLUS” High Light Output Systems - Small Can/Standard “F” Can - <20% THD
(High Ballast Factor ballasts may vary greatly in ballast factor between manufacturers/models - please refer to actual specs for details)
REL-2P32-HL-SC QT2x32T8/120ISH-SC B232I120RHH EH2/32IS-120
VEL-2P32-HL-SC QT2x32T8/277ISH-SC B232I277RHH EH2/32IS-277
REL-3P32-HL QT3x32/120PLUS B332I120RHH EH3/32IS-120
VEL-3P32-HL QT3x32/277PLUS B332I277RHH EH3/32IS-277
32 T8 Instant Start - Low Ballast Factor - Low Power(LP/ISL)Systems - SmallCan/Standard “F” Can - <20%THD
REL-1P32-LW-SC QT1x32T8/120ISL-SC N/A EL1/32IS-120
VEL-1P32-LW-SC QT1x32T8/277ISL-SC N/A EL1/32IS-277
REL-2P32-LW-SC QT2x32T8/120ISL-SC B232I120L-A EL2/32IS-120
VEL-2P32-LW-SC QT2x32T8/277ISL-SC B232I277L-A EL2/32IS-277
REL-3P32-LW-SC QT3x32T8/120ISL-SC B332I120L-A EL3/32IS-120
VEL-3P32-LW-SC QT3x32T8/277ISL-SC B332I277L-A EL3/32IS-277
REL-4P32-LW-RH-TP QT4x32/120LP B432I120L EL4/32IS-120
VEL-4P32-LW-RH-TP QT4x32/277LP B432I277L EL4/32IS-277
GEL-2P32-LW-RH-TP QT2x32T8/347ISL-SC B232I347L N/A
GEL-4P32-LW-RH-TP QT4x32/347LP B432I347L N/A
QUICKTRONIC®PROFESSIONAL 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS
32 T8 Instant Start - Normal Ballast Factor - Small Can - <10%THD
ICN-1P32-SC QTP1x32T8/UNVISN-SC B132IUNVHP-B EP1/32IS/120-277
ICN-2P32-SC QTP2x32T8/UNVISN-SC B232IUNVHP-B EP2/32IS/120-277
ICN-3P32-SC QTP3x32T8/UNVISN-SC B332IUNVHP-A EP3/32IS/120-277
ICN-4P32-SC QTP4x32T8/UNVISN-SC B432IUNVHP-A EP4/32IS/120-277
UNIVERSAL LIGHTING
|
TECHNOLOGIES GE
|
ADVANCE SYLVANIA (formerly Magnetek)* GENERAL ELECTRIC
|
32 T8 High Efficiency Instant Start - Normal Ballast Factor - Small Can - <10%THD
N/A QHE 1X32T8/UNV ISN-SC N/A GE-132-MAX-N/ULTRA
N/A QHE 2X32T8/UNV ISN-SC B232IUNVHE-A GE-232-MAX-N/ULTRA
N/A QHE 3X32T8/UNV ISN-SC B332IUNVHE-A GE-332-MAX-N/ULTRA
N/A QHE 4X32T8/UNV ISN-SC B432IUNVHE-A GE-432-MAX-N/ULTRA
32 T8 High Efficiency Instant Start - Low Ballast Factor - Small Can - <10%THD
N/A QHE 1X32T8/UNV ISL-SC N/A GE-132-MAX-L/ULTRA
N/A QHE 2X32T8/UNV ISL-SC B232IUNVEL-A GE-232-MAX-L/ULTRA
N/A QHE 3X32T8/UNV ISL-SC B332IUNVEL-A GE-332-MAX-L/ULTRA
N/A QHE 4X32T8/UNV ISL-SC B432IUNVEL-A GE-432-MAX-L/ULTRA
UNIVERSAL LIGHTING
|
TECHNOLOGIES HOWARD
|
ADVANCE SYLVANIA (formerly Magnetek)* INDUSTRIES
|
QUICKTRONIC®PROFESSIONAL 32 T8 PROStart®UNIVERSAL VOLTAGE SYSTEMS
32 T8 Programmed Rapid Start - Normal Ballast Factor - <10%THD
N/A QTP1x32T8/UNVPSN-TC B132PUNVHP-A N/A
N/A QTP2x32T8/UNVPSN-TC B232PUNVHP-A N/A
For more complete product information visit www.sylvania.com
290
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
ELECTRONIC FLUORESCENT LAMP BALLASTS UNIVERSAL LIGHTING
|
TECHNOLOGIES HOWARD
|
ADVANCE SYLVANIA (formerly Magnetek)* INDUSTRIES
|
32 T8 Programmed Rapid Start - Normal Ballast Factor - <10%THD
N/A QTP3x32T8/UNVPSN-SC B332PUNVHP-A N/A
N/A QTP4x32T8/UNVPSN-SC B432PUNVHP-A N/A
QUICKTRONIC®PROFESSIONAL 32 T8 PROStart®DEDICATED VOLTAGE SYSTEMS
32 T8 Programmed Rapid Start - Normal Ballast Factor - <10% THD
NOTE: UNV PSN models above replace Dedicated Voltage PSN models below.
(Programmed RS, Program RS)
RIC-132, RCN-1S32-SC QTP1x32T8/120PSN-TC B132P120RH N/A
VIC-132, VCN-1S32-SC QTP1x32T8/277PSN-TC B132P277RH N/A
RIC-2S32, RCN-2S32-SC QTP2x32T8/120PSN-SC B232P120RH N/A
VIC-2S32, VCN-2S32-SC QTP2x32T8/277PSN-SC B232P277RH N/A
RIC-3S32, RCN-3S32-SC QTP3x32T8/120PSN-SC B332P120RH N/A
VIC-3S32, VCN-3S32-SC QTP3x32T8/277PSN-SC B332P277RH N/A
RCN-4S32-SC QTP4x32T8/120PSN-SC B432P120RH N/A
VCN-4S32-SC QTP4x32T8/277PSN-SC B432P277RH N/A
QUICKTRONIC®59 T8, 59 PLUS, and QUICKTRONIC®PROFESSIONAL 8 foot Systems
59W F96 T8 Instant Start - Normal Ballast Factor - <20% THD
REL-2P59-S-RH-TP QT2x59/120IS B259I120RH E2/59IS-120
VEL-2P59-S-RH-TP QT2x59/277IS B259I277RH E2/59IS-277
GEL-2P59 QT2x59/347IS N/A N/A
59W F96 T8 Instant Start - High Ballast Factor (PLUS) Systems - <20% THD
REL-2P59-HL QT2x59/120PLUS B259I120RHH N/A
VEL-2P59-HL QT2x59/277PLUS B259I277RHH N/A
59W F96 T8 Instant Start - Normal Ballast Factor - <10% THD
RCN-2P59 QTP2x59T8/120ISN-A B259I120HE N/A
VCN-2P59 QTP2x59T8/277ISN-A B259I277HE N/A
QUICKTRONIC®PROFESSIONAL T5 HO PROStart®UNIVERSAL VOLTAGE SYSTEMS
T5 HO - Normal Ballast Factor - <10% THD
(Ballast Can Size varies between manufacturers - please refer to specifications for details)
ICN-2S39 (1 Lamp) QTP1x39-24T5HO/UNVPSN (FP39T5HO) B239PUNV-D (1 Lamp) N/A
ICN-2S39 QTP2x39-24T5HO/UNVPSN (FP39T5HO) B239PUNV-D N/A
ICN-2S24 (1 Lamp) QTP1x39-24T5HO/UNVPSN (FP24T5HO) B224PUNV-C (1 Lamp) N/A
ICN-2S24 QTP2x39-24T5HO/UNVPSN (FP24T5HO) B224PUNV-C N/A
ICN-2S54 (1 Lamp) QTP1x54T5HO/UNVPSN B254PUNV-D (1 Lamp) N/A
ICN-2S54 QTP2x54T5HO/UNVPSN B254PUNV-D N/A
ICN-1S80 QTP1x80T5HO/UNVPSN N/A N/A
QUICKTRONIC®PROFESSIONAL T5 PROStart®UNIVERSAL VOLTAGE SYSTEMS
28W T5 - Normal Ballast Factor - <10% THD
(Ballast Can Size varies between manufacturers - please refer to specifications for details)
ICN-2S28 (1 Lamp) QTP1x28T5/UNVPSN B228PUNV-C (1 Lamp) N/A
ICN-2S28 QTP2x28T5/UNVPSN B228PUNV-C N/A
QUICKTRONIC®Instant Start DL40
40W TT5 Instant Start, Normal Ballast Factor - <20% THD
N/A QT1x40/120DL C240I120RH, C240SI120RH (1 LAMP) E1/40IS-TT-120
N/A QT1x40/277DL C240I277RH, C240SI277RH (1 LAMP) E1/40IS-TT-277
N/A QT2x40/120DL C240I120RH, C240SI120RH E2/40IS-TT-120
N/A QT2x40/277DL C240I277RH, C240SI277RH E2/40IS-TT-277
N/A QT3x40/120DL C340I120RH, C340SI120RH E3/40IS-TT-120
N/A QT3x40/277DL C340I277RH, C340SI277RH E3/40IS-TT-277
QUICKTRONIC®PROFESSIONAL PROStart®DL40
40W TT5 Programmed Rapid Start, Normal Ballast Factor - <10% THD
REL-1TTS40 QTP1x40TT5/120PSN-F N/A N/A
VEL-1TTS40 QTP1x40TT5/277PSN-F N/A N/A
REL-2TTS40 QTP2x40TT5/120PSN-F N/A N/A
VEL-2TTS40 QTP2x40TT5/277PSN-F N/A N/A
N/A QTP3x40TT5/120PSN-B N/A N/A
N/A QTP3x40TT5/277PSN-B N/A N/A
QUICKTRONIC®PROFESSIONAL 32 T8 HELIOSDIMMING - A list of 0-10V controllers is available from OSRAM SYLVANIA
32 T8 Dimming Systems (0-10Vdc control) - 100-5% and 100-10% Dimming Range - <10% THD at full output, <20% THD at full dim
RZT-132 QTP1x32T8/120DIM5-B B132R120V5 N/A
VZT-132 QTP1x32T8/277DIM5-B B132R277V5 N/A
RZT-2S32 QTP2x32T8/120DIM5-B B232SR120V5 N/A
For more complete product information visit www.sylvania.com 291
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
ELECTRONIC FLUORESCENT LAMP BALLASTS UNIVERSAL LIGHTING
|
TECHNOLOGIES HOWARD
|
ADVANCE SYLVANIA (formerly Magnetek)* INDUSTRIES
|
32 T8 Dimming Systems (0-10Vdc control) - 100-5% and 100-10% Dimming Range - <10% THD at full output, <20% THD at full dim (continued)
VZT-2S32 QTP2x32T8/277DIM5-B B232SR277V5 N/A
RZT-3S32 QTP3x32T8/120DIM5-Q B332SR120V5 N/A
VZT-3S32 QTP3x32T8/277DIM5-Q B332SR277V5 N/A
N/A QTP4x32T8/120DIM10-Q N/A N/A
VZT-4S32 QTP4x32T8/277DIM10-Q N/A N/A
QUICKTRONIC®PROFESSIONAL 54 T5 HO HELIOSDIMMING - A list of 0-10V controllers is available from OSRAM SYLVANIA
54 T5 HO Dimming Systems (0-10Vdc control) - 100-1% Dimming Range -<10% THD at full output, <20% THD at full dim
RZT-154 QT1x54/120PHO-DIM N/A N/A
VZT-154 QT1x54/277PHO-DIM N/A N/A
RZT-2S54 QT2x54/120PHO-DIM N/A N/A
VZT-2S54 QT2x54/277PHO-DIM N/A N/A
QUICKTRONIC® 8 foot T12 Systems
96 T12 Instant Start - Normal Ballast Factor - Large Can (11.75”long) - <20% THD
REL-2P60-S QT2x96/120IS B260I120RH N/A
VEL-2P75-S QT2x96/277IS B260I277RH N/A
96 T12/HO Rapid Start - Normal Ballast Factor - Large Can (11.75”long) - <20% THD
REL-2S110 QT2x96/120HO B295SR120HP N/A
VEL-2S110 QT2x96/277HO B295SR277HP N/A
QUICKTRONIC®PROFESSIONAL 40 T12
40 T12 Rapid Start - Normal Ballast Factor - <10% THD
REL-1S40-RH-TP QTP1x40T12/120RSN-B B140R120HP N/A
VEL-1S40-RH-TP QTP1x40T12/277RSN-B B140R277HP N/A
RCN-2S40, REL-2S40-RH-TP QTP2x40T12/120RSN-B B240R120HP N/A
VCN-2S40, VEL-2S40-RH-TP QTP2x40T12/277RSN-B B240R277HP N/A
REL-3S40-RH-TP QTP3x40T12/120RSN-B B340R120HP N/A
VEL-3S40-RH-TP QTP3x40T12/277RSN-B B340R277HP N/A
QUICKTRONIC®PROFESSIONAL CF - UNIVERSAL VOLTAGE
CF T4 PROStart®- Programmed RapidStart - Normal Ballast Factor - <10% THD
CFL Products run multiple lamp combinations and have various mounting/case sizes. (refer to actual product specs)
UNIVERSAL LIGHTING
|
TECHNOLOGIES HOWARD ESI (Energy Savings Inc
|
ADVANCE SYLVANIA (formerly Magnetek)* INDUSTRIES is no longer in business)
|
ICF-2S13-H1-LD QTP1/2x13CF/UNVBS C213UNV-BE PSM213CQMVB ES-2/1-CFQ-13/10-UNV-C
ICF-2S13-H1-LD QTP1/2x13CF/UNVTS C213UNV-SE PSM213CQMV ES-2/1-CFQ-13/10-UNV-D
ICF-2S18-H1-LD QTP1/2x18CF/UNVBS C218UNV-BE PSM218CQMVB ES-2/1-CFQ-18-UNV-C
ICF-2S18-H1-LD QTP1/2x18CF/UNVTS C218UNV-SE PSM218CQMV ES-2/1-CFQ-18-UNV-D
ICF-2S26-H1-LD QTP2x26CF/UNVBS C2642UNV-BE PSG242TRMVB ES-2/1-CFQ-26-UNV-C
ICF-2S26-H1-LD QTP2x26CF/UNVTS C2642UNV-SE PSG242TRMV ES-2/1-CFQ-26-UNV-D
ICF-2S42-M2-LS QTP2x26/32/42CF/UNVBM C242UNV-BE PSG242TRMVB ES-2-CFH-42/32/26-UNV-H
ICF-2S42-M2-BS QTP2x26/32/42CF/UNVPM C242UNV-BES PSG242TRMVBS N/A
ICF-2S42-M2-LD QTP2x26/32/42CF/UNVTM C242UNV-SE N/A ES-2-CFH-42/32/26-UNV-G
ICF-2S42-M2-LS QTP1x57CF/UNVBM (1X57) C242UNV-BE N/A N/A
ICF-1Q70-M3-LD QTP1x57CF/UNVBM (1X70) C242UNV-BE N/A N/A
ICF-2S42-M2-BS QTP1x57CF/UNVPM (1X57) C242UNV-BES N/A N/A
ICF-1Q70-M3-BS QTP1x57CF/UNVPM (1X70) C242UNV-BES N/A N/A
*MagneTek Lighting has changed it's name to Universal Lighting Technologies.
For more complete product information visit www.sylvania.com
292
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
MAGNETIC FLUORESCENT LAMP BALLASTS UNIVERSAL LIGHTING
|
TECHNOLOGIES
|
ADVANCE SYLVANIA (formerly Magnetek)* VALMONT
|
T12 RAPID START
F30T12 Rapid Start - High Power Factor
R2SP30TP Mark III MB2x30/120RS-SRNK 573LTCP 8G3971W
V2SP30TP Mark III MB2x30/277RS-SRNK 588LTCP 8G3972W
F40T12 Rapid Start - High Power Factor
R140TP Mark III MB1x40/120RS-SRNK 412LSLHTCP 8G1074W
V140TP Mark III MB1x40/277RS-SRNK 458LSLHTCP 8G1084W
R2S40TP Mark III MB2x40/120RS-SRNK 446LSLHTCP 8G1024W
V2S40TP Mark III MB2x40/277RS-SRNK 443LSLHTCP 8G1034W
F40T12 Rapid Start - Normal Power Factor
RL140TP MB1x40/120RES-SRNK 413CTCP 8G1075
T12 INSTANT START SLIMLINE
F48T12 Instant Start - High Power Factor
SM2E40STP MB2x48/120IS-SRNK 213TCP 8G1600W
VSM2E40STP MB2x48/277IS-SRNK 532BRTCP 8G1710W
F96T12 Instant Start - High Power Factor
RSM175STP MB1x96/120IS-SRNK 822BRTCP 8G1762W
VSM175STP MB1x96/277IS-SRNK 828BRTCP 8G1764W
R2E75STP Mark III MB2x96/120IS-SRNK 806SLHTCP 8G1004W
V2E75STP Mark III MB2x96/277IS-SRNK 827SLHTCP 8G1014W
T12/HO RAPID START
F96T12/HO Rapid Start - High Power Factor
RS110TP MB1x96/HO/120RS-SRNK 481LHTCP ---
VS110TP MB1x96/HO/277RS-SRNK 479LHTCP ---
R2S110TP Mark III MB2x96/HO/120RS-SRNK 480SLHTCP ---
V2S110TP Mark III MB2x96/HO/277RS-SRNK 487SLHTCP ---
RS110TP MB1/2x48/96/HO/120RS-SRNK 490XLHTCP ---
T12/VHO RAPID START
F96T12/VHO Rapid Start - High Power Factor
RC2S102TP MB1x96/VHO/120RS-SRNK 951STCP ---
VC2S102TP MB1x96/VHO/277RS-SRNK 957STCP ---
RS2S200TP MB2x96/VHO/120RS-SRNK 930KTCP 8G1201W
VS2S200TP MB2x96/VHO/277RS-SRNK 937KTCP 8G1211W
T12/HO SIGN BALLASTS
T12/HO Rapid Start
ASB-0412-12-BL-TP MSB-12-0412-TP USB-0412-12 ---
ASB-0620-24-BL-TP MSB-24-0620-TP USB-0816-14 ---
ASB-1224-24-BL-TP MSB-24-1224-TP USB-1024-14 ---
ASB-2040-24-BL-TP MSB-24-2040-TP USB-1632-24 ---
ASB-1240-46-BL-TP MSB-46-1240-TP USB-2036-46 ---
ASB-2448-46-BL-TP MSB-46-2448-TP USB-2048-46 ---
T5, T8 AND T12 PREHEAT/TRIGGER START
F8T5 Preheat Start - Normal Power Factor
LSX113TP MB1x8/120PH/TP/S --- ---
F15T12 Trigger Start - Normal Power Factor
RLQ120TP MB1x15/120PH/TP 546BTCP 8G3560
F20T12 Preheat Start - Normal Power Factor
LC1420CTP MB1x20/120PH/TP 200H2P ---
LC1420C MB1x20/120PH 200H2 89G457
F20T12 Trigger Start - Normal Power Factor
RL2SP20TP MB2x20/120PH/TP 447LRTCP 8G3912
T8 RAPID START
F017T8 Rapid Start - Normal Power Factor
--- MB1x17/120RS 707TCP ---
F025T8 or F032T8 Rapid Start - High Power Factor
--- MB1x25/32/120RS-LW M132R120 ---
R1P825TP & R1P32TP Mark III MB1x25/32/120RS-SRNK 727LTCP & M132R120 ---
V1P825TP & V1P32TP Mark III MB1x25/32/277RS-SRNK 728LTCP & M132R277C ---
R2P825TP & R2P32TP Mark III MB2x25/32/120RS-SRNK 731LTCP & M232SR120C ---
V2P825TP & V2P32TP Mark III MB2x25/32/277RS-SRNK 732LTCP & M232SR277C
For more complete product information visit www.sylvania.com 293
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
MAGNETIC FLUORESCENT LAMP BALLASTS UNIVERSAL LIGHTING
|
TECHNOLOGIES
|
ADVANCE SYLVANIA (formerly Magnetek)* VALMONT
|
T9 CIRCLINE RAPID START
FC8T9 Circline Rapid Start - Normal Power Factor
RLQS122TPW MB1x22/120CIRC 547RSWSTCP 8G1091G11
FC12T9 or FC16T9 Circline Rapid Start - Normal Power Factor
RLCS140TPW MB1x32/120CIRC 445RSWSTCP 8G1085G11
*MagneTek Lighting has changed it's name to Universal Lighting Technologies.
MAGNETIC HID LAMP BALLASTS UNIVERSAL LIGHTING TECHNOLOGIES
|
(formerly Magnetek)* VENTURE HOWARD
|
ADVANCE SYLVANIA OLD PART NUMBER NEW PART NUMBER LIGHTING INDUSTRIES
|
METALARC®METAL HALIDE CORE & COIL BALLAST KITS
35W Metal Halide Lamp - ANSI Code M130
--- M35/MULTI-HQ/CI-KIT --- --- --- ---
71A5081 M35/120/277-KIT --- --- --- ---
50W Metal Halide Lamp - ANSI Code M110 or M148
--- M50/MULTI-KIT --- M50MLTLC3M & V90D5731K ---
M50MLTLC3M-500K
71A5181 M50/120/277-KIT 11310-236-500K --- V90H5731K ---
70W Metal Halide Lamp - ANSI Code M98 or M143
71A5292 & 71A5292-001D M70/MULTI-KIT 11310-510-500K M70MLTLC3M & V90D5832K ---
M70MLTLC3M-500K
71A5282 M70/120/277-KIT --- --- V90H5832K ---
70W Metal Halide Lamp - ANSI Code M98 or M143 or M85
--- M70/MULTI-HQ/CI-KIT --- --- V90D5810K ---
100W Metal Halide Lamp - ANSI Code M90 or M140
71A5390 & 71A5390-001D M100/MULTI-KIT 11310-90-500K M100MLTLC3M & V90D5932K M010071C511K
M100MLTLC3M-500K
71A5380 M100/120/277-KIT --- --- V90H5932K ---
150W Metal Halide Lamp, Medium Base - ANSI Code M102 or M142
71A5492 M150/MULTI-PS-KIT 11310-543-500K M150MLTLC3M & V90D7130K ---
M150MLTLC3M-500K
--- M150/MULTI-PS-CWA-KIT --- --- V90D7110K ---
71A5482 M150/120/277-PS-KIT --- --- --- ---
150W Metal Halide Lamp, Double-Ended - ANSI Code M81
71A5490 M150/MULTI-KIT 11310-177-500K M150MLTLC3D & --- ---
M150MLTLC3D-500K
175W Metal Halide Lamp - ANSI Code M57 or Mercury Lamp - ANSI Code H39
--- M175/SUPER5-KIT --- M175ML5AC3M & --- ---
M175ML5AC3M-500K
71A5590 & 71A5570-001D M175/MULTI-KIT 1130-91R-500K M175MLTAC3M & V90D6111K M017571C211K
M175MLTAC3M-500K
71A5540 & 71A5540-001D M175/480-KIT 1130-31-500K --- --- ---
71A5540T M175/480/120T-KIT --- M17548TAC3M & --- ---
M17548TAC3M-500K
71A5580 M175/120/277-KIT 1130-245R-500K --- --- ---
175W Metal Halide Pulse Start Lamp - ANSI Code M137
71A5593 & 71A5593-001D M175/MULTI-PS-KIT --- P175MLTAC3M & V90D7210K ---
P175MLTAC3M-500K
--- M175/480-PS-KIT --- --- --- ---
200W Metal Halide Pulse Start Lamp - ANSI Code M136
71A5692 & 71A5692-001D M200/MULTI-PS-KIT --- P200MLTAC3M & V90D7310K ---
P200MLTAC3M-500K
--- M200/480/-PS-KIT --- --- --- ---
71A5642T M200/480/120T-PS-KIT --- P20048TAC3M & V90Y7310TK ---
P20048TAC3M-500K
For more complete product information visit www.sylvania.com
294
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
MAGNETIC HID LAMP BALLASTS UNIVERSAL LIGHTING TECHNOLOGIES
|
(formerly Magnetek)* VENTURE HOWARD
|
ADVANCE SYLVANIA OLD PART NUMBER NEW PART NUMBER LIGHTING INDUSTRIES
|
250W Metal Halide Lamp - ANSI Code M58 or Mercury Lamp - ANSI Code H37
71A5750 & 71A5750-001D M250/SUPER5-KIT --- M250ML5AC4M & --- ---
M250ML5AC4M-500K
71A5790 & 71A5770-001D M250/MULTI-KIT 1130-92R-500K M250MLTAC4M & V90D6212K M025071C211K
M250MLTAC4M-500K
71A5740 & 71A5740-001D M250/480-KIT 1130-32R-500K --- --- M025011C211K
71A5740T M250/480/120T-KIT --- M25048TAC4M & V90Y6212TK ---
M25048TAC4M-500K
71A5791 & 71A5771-001D M250/MULTI 3X4-KIT 1130-92-500K M250MLTAC3M & V90D6211K ---
M250MLTAC3M-500K
71A5741 & 71A5741-001D M250/480-3X4-KIT 1130-32-500K --- V90Y6211K ---
250W Metal Halide Lamp - ANSI Code M80
71A5880 M250/120/277-KIT --- --- --- ---
250W Metal Halide Pulse Start Lamp - ANSI Code M138
--- M250/SUPER5-PS-KIT --- --- --- ---
71A5792 & 71A5792-001D M250/MULTI-PS-KIT --- P250MLTAC4M & V90D8410K M025071C611K
P250MLTAC4M-500K
--- M250/480-PS-KIT --- --- --- ---
--- M250/480/120T-PS-KIT --- P25048TAC4M & --- ---
P25048TAC4M-500K
320W Metal Halide Pulse Start Lamp - ANSI Code M132
71A5892 & 71A5892-001D M320/MULTI-PS-KIT --- P320MLTAC4M & V90D7411K M032071C611K
P320MLTAC4M-500K
--- M320/480-PS-KIT --- --- --- ---
71A5842T M320/480/120T-PS-KIT --- P32048TAC4M & V90Y7411TK ---
P32048TAC4M-500K
350W Metal Halide Pulse Start Lamp - ANSI Code M131
71A5993 & 71A5993-001D M350/MULTI-PS-KIT --- P350MLTAC4M & V90D7512K M035071C611K
P350MLTAC4M-500K
--- M350/480-PS-KIT --- --- --- ---
71A5943T M350/480/120T-PS-KIT --- P35048TAC4M & V90Y7512TK ---
P35048TAC4M-500K
400W Metal Halide Lamp - ANSI Code M59 or Mercury Lamp - ANSI Code H33
71A6051 & 71A6051-001D M400/SUPER5-KIT --- M400ML5AC4M & --- M040081C211K
M400ML5AC4M-500K
71A6091 & 71A6071-001D M400/MULTI-KIT 1130-93R-500K M400MLTAC4M & V90D6413K M040071C211K
M400MLTAC4M-500K
71A6041 & 71A6041-001D M400/480-KIT 1130-33R-500K --- --- M040011C211K
71A6041T M400/480/120T-KIT --- M40048TAC4M & V90Y6413TK ---
M40048TAC4M-500K
400W Metal Halide Pulse Start Lamp - ANSI Code M135
--- M2x400/120/240-KIT --- --- --- ---
--- M400/SUPER5-PS-KIT --- --- --- ---
71A6092 & 71A6092-001D M400/MULTI-PS-KIT --- P400MLTAC4M & V90D7612K M040071C611K
P400MLTAC4M-500K
--- M400/480-PS-KIT --- --- --- ---
71A6042T M400/480/120T-PS-KIT --- P40048TAC4M & V90Y7612TK ---
P40048TAC4M-500K
450W Metal Halide Pulse Start Lamp - ANSI Code M144
71A6393 M450/MULTI-PS-KIT --- P450MLTAC4M & V90D8512K ---
P450MLTAC4M-500K
--- M450/480-PS-KIT --- --- --- ---
71A6343T M450/480/120T-PS-KIT --- --- V90Y8511TK ---
750W Metal Halide Pulse Start Lamp - ANSI Code M149
71A64E2 M750/MULTI-PS-KIT --- P750MLTAC5M & V90D7910K ---
P750MLTAC5M-500K
71A64F2T M750/120/277/347/480-PS-KIT --- --- V90J7910K ---
--- M750/480-PS-KIT --- --- --- ---
1000W Metal Halide Lamp - ANSI Code M47 or Mercury Lamp - ANSI Code H36
71A6552 & 71A6552-001 M1000/SUPER5-KIT --- M1000ML5AC5M & V90AM6514K ---
M1000ML5AC5M-500K
For more complete product information visit www.sylvania.com 295
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
MAGNETIC HID LAMP BALLASTS UNIVERSAL LIGHTING TECHNOLOGIES
|
(formerly Magnetek)* VENTURE HOWARD
|
ADVANCE SYLVANIA OLD PART NUMBER NEW PART NUMBER LIGHTING INDUSTRIES
|
1000W Metal Halide Lamp - ANSI Code M47 or Mercury Lamp - ANSI Code H36 (continued)
71A6592 & 71A6572-001 M1000/MULTI-KIT 1130-97-500K M1000MLTAC5M & V90D6514K M0100071C212K
M1000MLTAC5M-500K
71A6542 & 71A6542-001 M1000/480-KIT 1130-57-500K M1000480AC5M & --- M0100011C212K
M1000480AC5M-500K
71A6542T M1000/480/120T-KIT --- M100048TAC5M & V90Y6514TK ---
M100048TAC5M-500K
1000W HQI Metal Halide Lamp
--- M1000/MULTI-HQI-KIT --- --- --- ---
1000W Metal Halide Pulse Start Lamp - ANSI Code M141
71A6593 M1000/MULTI-PS-KIT --- P1000MLTAC5M & V90D7810K ---
P1000MLTAC5M-500K
71A65F3T M1000/120/277/347/480-PS-KIT --- --- V90J7810K ---
--- M1000/480-PS-KIT --- --- --- ---
1500W Metal Halide Lamp - ANSI Code M48
71A6792 & 71A6772-001 M1500/MULTI-KIT 1130-99R-500K M1500MLTAC5M & V90D6612K M0150071C212K
M1500MLTAC5M-500K
71A6742 & 71A6742-001 M1500/480-KIT 1130-69R-500K M1500480AC5M & --- M0150011C212K
M1500480AC5M-500K
--- M1500/480/120T-KIT --- M150048TAC5M & V90Y6612TK ---
M150048TAC5M-500K
2000W HQI Metal Halide Lamp
--- M2000/277/347/480-HQI-RL-KIT --- --- --- ---
METALARC®METAL HALIDE F-CAN HID BALLASTS
35W Metal Halide Lamp - ANSI Code M130
72C5081-NP M35/120/277/F-CAN --- --- --- ---
50W Metal Halide Lamp - ANSI Code M110
72C5181-NP&72C5181-NP-001 M50/120/277/F-CAN --- 11210-236C-TC --- ---
70W Metal Halide Lamp - ANSI Code M139
72C5281-NP M70/120/277/F-CAN --- --- --- ---
70W Metal Halide Lamp - ANSI Code M98 or M143
72C5282-NP&72C5282-NP-001 M70/120/277/F-CAN --- 11210-506C-TC --- ---
100W Metal Halide Lamp - ANSI Code M90 or M140
72C5381-NP&72C5381-NP-001 M100/120/277/F-CAN --- 11210-239C-TC --- ---
150W Metal Halide Lamp, Medium Base - ANSI Code M102 or M142
--- M150-PS/120/277/F-CAN --- --- --- ---
175W Metal Halide Lamp - ANSI Code M57 or Mercury Lamp - ANSI Code H39
72C5581-NP&72C5581-NP-001 M175/120/277/F-CAN --- 1110-245SC-TC --- ---
175W Metal Halide Pulse Start Lamp - ANSI Code M137
72C5582-NP&72C5582-NP-001 M175-PS/120/277/F-CAN --- --- --- ---
200W Metal Halide Pulse Start Lamp - ANSI Code M136
--- M200-PS/120/277/F-CAN --- --- --- ---
250W Metal Halide Lamp - ANSI Code M58 or Mercury Lamp ANSI Code H37
72C5782-NP&72C5782-NP-001 M250/120/277/F-CAN --- 1110-246C-TC --- ---
250W Metal Halide Pulse Start Lamp - ANSI Code M138
72C5783-NP&72C5783-NP-001 M250-PS/120/277/F-CAN --- --- --- ---
320W Metal Halide Pulse Start Lamp - ANSI Code M132
72C5882-NP&72C5882-NP-001 M320-PS/120/277/F-CAN --- P320277AFXM --- ---
400W Metal Halide Lamp - ANSI Code M59 or Mercury Lamp - ANSI Code H33
72C6082-NP&72C6082-NP-001 M400/120/277/F-CAN --- 1110-247SC-TC --- ---
400W Metal Halide Pulse Start Lamp - ANSI Code M135
72C6182-NP&72C6182-NP-001 M400-PS/120/277/F-CAN --- --- --- ---
METALARC®METAL HALIDE INDOOR ENCLOSED HID BALLASTS
175W Metal Halide Lamp - ANSI Code M57 or Mercury Lamp - ANSI Code H39
78E5590-001 M175/MULTI-I/D --- 337-1770 --- ---
250W Metal Halide Lamp - ANSI Code M58 or Mercury Lamp - ANSI Code H37
78E5790-001 M250/MULTI-I/D --- 337-1750 --- ---
400W Metal Halide Lamp - ANSI Code M59 or Mercury Lamp - ANSI Code H33
78E6091-001 M400/MULTI-I/D --- 337-1780 --- ---
1000W Metal Halide Lamp - ANSI Code M47 or Mercury Lamp - ANSI Code H36
78E6592-001 M1000/MULTI-I/D --- 337-1790 --- ---
For more complete product information visit www.sylvania.com
296
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference Guide (continued)
MAGNETIC HID LAMP BALLASTS UNIVERSAL LIGHTING TECHNOLOGIES
|
(formerly Magnetek)* VENTURE HOWARD
|
ADVANCE SYLVANIA OLD PART NUMBER NEW PART NUMBER LIGHTING INDUSTRIES
|
LUMALUX®HIGH PRESSURE SODIUM CORE & COIL REACTOR BALLASTS
35W High Pressure Sodium Lamp - ANSI Code S76
71A7707 LU35/120R 1233-251U --- --- ---
71A7707B LU35/120R-INT --- --- --- ---
50W High Pressure Sodium Lamp - ANSI Code S68
71A7807 LU50/120R 1233-35U --- --- ---
71A7807B LU50/120R-INT --- --- --- ---
70W High Pressure Sodium Lamp - ANSI Code S62
71A7907 LU70/120R 1233-142U --- --- ---
71A7907B LU70/120R-INT --- --- --- ---
100W High Pressure Sodium Lamp - ANSI Code S54
71A8007 LU100/120R 1233-10U --- --- ---
71A8007B LU100/120R-INT --- --- --- ---
150W High Pressure Sodium Lamp - ANSI Code S55
71A8107 LU150/120R 1233-154U --- --- ---
71A8107B LU150/120R-INT --- --- --- ---
LUMALUX®HIGH PRESSURE SODIUM CORE & COIL BALLAST KITS
35W High Pressure Sodium Lamp - ANSI Code S76
--- LU35/120/240-KIT --- --- --- ---
50W High Pressure Sodium Lamp - ANSI Code S68
71A7801 & 71A7801-001D LU50/120/277-KIT 12310-236-500K --- V90H1132K ---
70W High Pressure Sodium Lamp - ANSI Code S62
71A7991 & 71A7971-001D LU70/MULTI-KIT 12310-153-500K S70MLTLC3M & V90D1233K S007071C511K
S70MLTLC3M-500K
71A7941 LU70/480-KIT 12310-148R-500K --- --- ---
71A7901 LU70/120/277-KIT 12310-237-500K --- --- ---
100W High Pressure Sodium Lamp - ANSI Code S54
71A8091 & 71A8071-001D LU100/MULTI-KIT 12310-90-500K S100MLTLC3M & V90D1333K S010071C511K
S100MLTLC3M-500K
71A8041 & 71A8041-001D LU100/480-KIT 12310-30R-500K --- --- ---
71A8001 LU100/120/277-KIT 12310-239-500K --- --- ---
150W High Pressure Sodium Lamp - ANSI Code S55
71A8192 & 71A8172-001D LU150/MULTI-KIT 12310-165-500K S150MLTLC3M & V90D1435K S015071C511K
S150MLTLC3M-500K
71A8142 & 71A8142-001D LU150/480-KIT 12310-160S-500K --- --- ---
71A8142T LU150/480/120T-KIT S15048TLC3M & --- ---
S15048TLC3M-500K
71A8102 LU150/120/277-KIT 12310-241-500K --- --- ---
71A8148 LU150/480-CWA-KIT --- --- --- ---
200W High Pressure Sodium Lamp - ANSI Code S66
71A8990 & 71A8970-001D LU200/MULTI-KIT 1230-190-500K S200MLTAC4M & V90D1610K ---
S200MLTAC4M-500K
71A8940 & 71A8940-001D LU200/480-KIT 1230-186-500K --- --- ---
250W High Pressure Sodium Lamp - ANSI Code S50
71A8251 & 71A8251-001D LU250/SUPER5-KIT --- S250ML5AC4M & --- ---
S250ML5AC4M-500K
71A8291 & 71A8271-001D LU250/MULTI-KIT 1230-92S-500K S250MLTAC4M & V90D1711K S025071C211K
S250MLTAC4M-500K
71A8241 & 71A8241-001D LU250/480-KIT 1230-32S-500K --- --- ---
71A8241T LU250/480/120T-KIT S25048TAC4M & --- ---
S25048TAC4M-500K
71A8281 LU250/120/277-KIT 1230-246S-500K --- --- ---
310W High Pressure Sodium Lamp - ANSI Code S67
71A8391 & 71A8371-001D LU310/MULTI-KIT --- --- V90D1810K ---
71A8341 LU310/480-KIT --- --- --- ---
400W High Pressure Sodium Lamp - ANSI Code S51
71A8453 & 71A8453-001D LU400/SUPER5-KIT --- S400ML5AC4M & --- ---
S400ML5AC4M-500K
71A8493 & 71A8473-001D LU400/MULTI-KIT 1230-93U-500K S400MLTAC4M & V90D1911K / S040071C211K
S400MLTAC4M-500K V90D1912K
71A8443 & 71A8443-001D LU400/480-KIT 1230-33U-500K --- --- S040011C211K
For more complete product information visit www.sylvania.com 297
C
R
O
S
S
R
E
F
E
R
E
N
C
E
Manufacturers’ Cross Reference (continued)
MAGNETIC HID LAMP BALLASTS UNIVERSAL LIGHTING TECHNOLOGIES
|
(formerly Magnetek)* VENTURE HOWARD
|
ADVANCE SYLVANIA OLD PART NUMBER NEW PART NUMBER LIGHTING INDUSTRIES
|
400W High Pressure Sodium Lamp - ANSI Code S51 (continued)
71A8443T LU400/480/120T-KIT --- S40048TAC4M & --- ---
S40048TAC4M-500K
--- LU400/120/277-KIT --- --- --- ---
750W High Pressure Sodium Lamp - ANSI Code S111
71A86E5 LU750/MULTI-KIT --- --- --- ---
--- LU750/480-KIT --- --- --- ---
1000W High Pressure Sodium Lamp - ANSI Code S52
71A8753 & 71A8753-001 LU1000/SUPER5-KIT --- S1000ML5AC5M & --- ---
S1000ML5AC5M-500K
71A8793 & 71A8773-001 LU1000/MULTI-KIT 1230-97S-500K S1000MLTAC5M & V90D2311K S100071C211K
S1000MLTAC5M-500K
71A8743 & 71A8743-001 LU1000/480-KIT 1230-57S-500K --- --- S100011C211K
LUMALUX®HIGH PRESSURE SODIUM F-CAN HID BALLASTS
35W High Pressure Sodium Lamp - ANSI Code S76
--- LU35/120/277/F-CAN --- 12210-261C-TC --- ---
50W High Pressure Sodium Lamp - ANSI Code S68
72C7884-NP & 72C7884-NP-001 LU50/120/277/F-CAN --- 12210-236C-TC --- ---
70W High Pressure Sodium Lamp - ANSI Code S62
72C7984-NP & 72C7984-NP-001 LU70/120/277/F-CAN --- 12210-237C-TC --- ---
100W High Pressure Sodium Lamp - ANSI Code S54
72C8084-NP & 72C8084-NP-001 LU100/120/277/F-CAN --- 12210-239C-TC --- ---
150W High Pressure Sodium Lamp - ANSI Code S55
--- LU150/120/277/F-CAN --- --- --- ---
250W High Pressure Sodium Lamp - ANSI Code S50
--- LU250/120/277/F-CAN --- 1220-246C-TC --- ---
400W High Pressure Sodium Lamp - ANSI Code S51
--- LU400/120/277/F-CAN --- --- --- ---
MERCURY CORE & COIL BALLAST KITS
50W Mercury Lamp - ANSI Code H46
--- H50/MULTI-KIT --- --- --- ---
75W Mercury Lamp - ANSI Code H43
71A2080 H75/MULTI-KIT --- --- --- ---
100W Mercury Lamp - ANSI Code H38 or H44
71A2591 & 71A2571-001D H100/MULTI-KIT 1030-90R-500K H100MLTAC3M & --- ---
H100MLTAC3M-500K
--- H100/277-KIT --- --- --- ---
71A2501 H100/DUAL-KIT --- --- --- ---
175W Mercury Lamp - ANSI Code H39
71A3092 & 71A3072-001D H175/MULTI-KIT 1030-91-500K H175MLTAC3M & --- ---
H175MLTAC3M-500K
71A3042 & 71A3042 -001D H175/480-KIT 1030-31-500K --- --- ---
250W Mercury Lamp - ANSI Code H37
71A3592 & 71A3572-001D H250/MULTI-KIT 1030-92-500K H250MLTAC3M & --- ---
H250MLTAC3M-500K
71A3542 & 71A3542-001D H250/480-KIT 1030-32-500K --- --- ---
71A3542T H250/480/120T-KIT --- H25048TAC3M & --- ---
H25048TAC3M-500K
400W Mercury Lamp - ANSI Code H33
71A4091 & 71A4071-001D H400/MULTI-KIT 1030-93-500K H400MLTAC4M & --- ---
H400MLTAC4M-500K
71A4041 & 71A4041-001D H400/480-KIT 1030-33-500K --- --- ---
71A4041T H400/480/120T-KIT --- H40048TAC4M & --- ---
H40048TAC4M-500K
--- H2X400/120-KIT --- --- --- ---
--- H2X400/277-KIT --- --- --- ---
1000W Mercury Lamp - ANSI Code H36
71A5070-001 H1000/MULTI-KIT 1030-97-500K H1000MLTAC5M & --- ---
H1000MLTAC5M-500K
71A5040-001 H1000/480-KIT 1030-57-500K --- --- ---
*MagneTek Lighting has changed it's name to Universal Lighting Technologies.
For more complete product information visit www.sylvania.com
298
I
N
D
E
X
Index
INCANDESCENT LAMPS
Incandescent Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Lamp Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Bulb Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Base Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Filament Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Incandescent Lamp Shapes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
How to Read Product Information Incandescent . . . . . . . . . . . . . . . . . . . . . . .5
Incandescent Brand Name Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
DaylightLamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Double Life Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
General Purpose Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-27
Decorative Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27-31
Traffic Signal Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Symbols & Footnotes for Incandescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . .33
HALOGEN LAMPS
Halogen Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Filaments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
How to Read Product Information Tungsten Halogen . . . . . . . . . . . . . . . . . .36
ANSI Beam Angle Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Life Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Tungsten Halogen Brand Name Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
CAPSYLITE® A-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
CAPSYLITE® A-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Daylight™ PLUS A-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Tubular Halogen T10 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Infrared Conserving Halogen Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
TRU-AIM IR® MR16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
CAPSYLITE IR PAR 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
CAPSYLITE IR® PAR30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-40
CAPSYLITE IR® PAR38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
CAPSYLITE® PAR Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Daylight PLUS PAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
CAPSYLITE® PAR14 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
DESIGNER 16® - CAPSYLITE® PAR16 Lamps . . . . . . . . . . . . . . . . . . . . .41
CAPSYLITE® IR PAR20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
CAPSYLITE® PAR20 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
CAPSYLITE IR® PAR30 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42-43
CAPSYLITE® PAR30 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
CAPSYLITE® PAR30 Long Neck Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .44
CAPSYLITE® PAR36 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
CAPSYLITE IR® PAR38 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
CAPSYLITE® PAR38 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45-47
CAPSYLITE COOL LUX Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
CAPSYLITE COOL LUX PAR30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
CAPSYLITE COOL LUX PAR38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Large PAR Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
CAPSYLITE® G9 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
SUPER Q® - Single Ended Quartz Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Double End Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49-50
Double End Quartz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49-50
BI-PIN Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
STARLITE® BI-PIN Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Standard BI-PIN Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
BI-PIN Lamps 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
TRU-AIM IR® MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
TRU-AIM TITAN® MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51-52
TRU-AIM BRILLIANT® MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
TRU-AIM® MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
TRU-AIM® MR11 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
TRU-AIM® Covered MR Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
TRU-AIM TITAN® Covered MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . .54
TRU-AIM BRILLIANT® Covered MR16 Lamps . . . . . . . . . . . . . . . . . . . . .54
TRU-AIM Covered MR11 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Aluminum Reflector Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
AR70 Aluminum Reflector Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
AR111 Aluminum Reflector Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .54-55
SIRIUS MR16 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Symbols & Footnotes for Tungsten Halogen Lamps . . . . . . . . . . . . . . . . . .56-57
MINIATURE LAMPS
Miniature Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58-60
Symbols & Footnotes for Miniature Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
HIGH INTENSITY DISCHARGE (HID) LAMPS
Understanding High Intensity Discharge Lighting . . . . . . . . . . . . . . . . . . . . .62-63
How to Read Product Information - HID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Bulbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Operating Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
HID Brand Name Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
HID Color Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Guide to Metal Halide Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Metal Halide Warnings & Operating Instructions . . . . . . . . . . . . . . . . . . . . .68-73
METALARC® Metal Halide Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
METALARC® Powerball® Ceramic Lamps . . . . . . . . . . . . . . . . . . . . . . . .74
METALARC® Powerball Ceramic - PAR Lamps . . . . . . . . . . . . . . . . . .74-75
METALARC® Pulse Start Lamps & Metalarc PRO-TECH . . . . . . . . . .75-76
METALARC® Pulse Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76-77
METALARC® SUPERSAVER® Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
METALARC® Super Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77-78
Standard METALARC & METALARC® PRO-TECH Lamps . . . . . . . . .78-79
METALARC® BRITELINE Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
METALARC® SAFELINE® Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
HQI® Metal Halide Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Guide to High Pressure Sodium Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
High Pressure Sodium Warnings & Operating Instructions . . . . . . . . . . . .81-83
LUMALUX® High Pressure Sodium Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .84
LUMALUX PLUS®/ECO® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
LUMALUX HGF/ECO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84
LUMALUX Standard & LUMALUX ECO . . . . . . . . . . . . . . . . . . . . . . . . .84-85
LUMALUX Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
UNALUX® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Specialty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
SOX Low Pressure Sodium Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Guide to Mercury Vapor Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87
Mercury Vapor Warnings & Operating Instructions . . . . . . . . . . . . . . . . . . .87-88
Mercury Vapor Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
Guide to Reprographic / Photochemical Lamps . . . . . . . . . . . . . . . . . . . . . . . . .90
Reprographic / Photochemical Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
and Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90-91
Reprographic / Photochemical Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Lamp & Ballast System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Symbols & Footnotes for HID Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93-94
For more complete product information visit www.sylvania.com 299
I
N
D
E
X
Index (continued)
FLUORESCENT LAMPS
Fluorescent Lamp Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
How To Read Product Information - Compact . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96
How to Read Product Information - Fluorescent Lamps . . . . . . . . . . . . . . . . . .97
Fluorescent Lamp Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Fluorescent Brand Name Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Color Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Electrical Interchangeability Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101-102
Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103
Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
DULUX® S Preheat 2-Pin ECOLOGIC®
Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
DULUX® S/E 4-Pin Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . .106
DULUX® D Preheat 2-Pin ECOLOGIC® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106-107
DULUX® D/E 4-Pin ECOLOGIC®
Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
DULUX® T Preheat 2-Pin Ecologic Compact Fluorescent Lamps . . . . . . . .107
DULUX® T/E 4-Pin Ecologic Compact Fluorescent Lamps . . . . . . . . . .107-108
DULUX® T/E/IN Amalgam, 4-Pin Ecologic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . .108-109
DULUX® L High Lumen Compact Fluorescent Lamps . . . . . . . . . . . . . .109-110
DULUX® F Flat Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . .110
DULUX® EL Self-Ballasted Compact Fluorescent Lamps . . . . . . . . . . . . . . . .110
Triple Tube Compact Fluroescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . .110
Mini Twist Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . .110-111
Twist Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .111-112
Classic (A-shape) Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . .112
Decorative Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . .112
Globe Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Reflector Compact Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . .112-113
Low Profile Bullet and Circline Elecctronic Compact . . . . . . . . . . . . . . . . .113
OCTRON® and OCTRON® CURVALUME® Fluorescent Lamps . . . . . . . . .114
OCTRON® 700 and 700 XP™ Lamps . . . . . . . . . . . . . . . . . . . . . . . .114-115
OCTRON® 800, 800 XP and 800 XPS® Lamps . . . . . . . . . . . . . . .115-118
OCTRON® 5000K and 6500K for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Displays, Signage and Backlighting . . . . . . . . . . . . . . . . . . . . . . .118
OCTRON® Curvalume® U-Shaped Lamps
with 1 5/8” Leg Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . .118-119
OCTRON® Curvalume® U-Shaped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lamps with 6” Leg Spacing . . . . . . . . . . . . . . . . . . . . . . . . .119-120
PENTRON® T5 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
PENTRON® High Performance T5 Lamps . . . . . . . . . . . . . . . . . . . .120-121
PENTRON® High Performance, High Output T5 Lamps . . . . . . . . .121-122
PENTRON® Circline High Performance T5 Lamps . . . . . . . . . . . . .122-123
Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
3' SUPERSAVER® Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .123
3' Standard Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
4' SUPERSAVER® Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . .123-124
4' Standard Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124-125
CURVALUME® Rapid Start SUPERSAVER® -
U-Shaped, 6" Leg Spacing . . . . . . . . . . . . . . . . . . . . . . . . . .125-126
CURVALUME® Rapid Start - Standard Lamps U-Shaped 6" Leg Spacing .126
Circline T9 Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
High Output (800mA) Rapid Start SUPERSAVER® Lamps . . . . . . . . . .126-127
High Output (800mA) Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . .127-128
High Output (800mA) Rapid Start Lamps for
Cold Temperature Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
Very High Output (1500mA) Rapid Start Lamps . . . . . . . . . . . . . . . . . . . . . . .129
Instant Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
Slimline Instant Start SUPERSAVER® Lamps . . . . . . . . . . . . . . . . .129-130
Slimline Instant Start Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130-131
Instant Start Bipin Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Preheat Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Miniature T5 Preheat Lamps (Starter Required) . . . . . . . . . . . . . . . . . . . .132
Standard T8 and T12 Preheat Lamps (Starter Required) . . . . . . . . .132-134
Specialty Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
SAFELINE® Shatter Resistant Coated Lamps . . . . . . . . . . . . . . . . . . . . . .134
Weather-Shielded Jacketed Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
GRO-LUX® Lamps for Plant Growth & Aquariums . . . . . . . . . . . . . . . . .134
Miniature T2 Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
ICETRON® Inductively Coupled, Electrodeless Lamps . . . . . . . . . .135-136
Blacklight, Preheat Lamps (Starter Required) . . . . . . . . . . . . . . . . . . . . . .136
Blacklight, Rapid Start Lamps (No Starter Required) . . . . . . . . . . . . . . . .136
Blacklight Blue, Preheat Lamps (Starter Required) . . . . . . . . . . . . . . . . . .136
Blacklight Blue, Rapid Start Lamps (No Starter Required) . . . . . . . . . . . .137
Germicidal Preheat Lamps (Starter Required) . . . . . . . . . . . . . . . . . . . . . .137
Fluorescent Preheat Lamp Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
Glostat Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
COP Starters with Cutout And Manual Reset . . . . . . . . . . . . . . . . . . . . . . . . . .138
HID Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
Symbols & Footntoes for Fluorescent Lamps . . . . . . . . . . . . . . . . . . . . .139-143
QUICKTRONIC® ELECTRONIC BALLASTS
The System Solution™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
How to Read Product Information - Electronic Ballasts . . . . . . . . . . . . . . . . . .145
Ballast Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
QUICKTRONIC® T8 Fluorescent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
T8 Instant Start, <20%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Normal Light Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
High Light Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146-147
Low Power Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
T8 Instant Start, <10%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
T8 Instant Start, <20% THD Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
T8 Instant Start Start, <10%THD
Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147
High Efficiency, Instant Start < 10%
Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
T8 Programmed Start, <10% THD
Universal Voltage Xtreme System Low Ballast Factor . . . . . . . . . . . .148
Universal Voltage SUPERSAVER Xtreme System . . . . . . . . . . . . . . .148
Universal Voltage Normal Light Output . . . . . . . . . . . . . . . . . . . . . . . .149
T8 Instant Start, <20%, 8 Foot
Normal Light Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
High Light Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
T8 Instant Start, < 10%, 8 Foot
Normal Light Output - Universal Voltage . . . . . . . . . . . . . . . . . . . . . . .149
QUICKTRONIC® T5 Linear Fluorescent
T5HO Programmed Start, <10%THD
Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149-150
T5 Programmed Start, <10% THD
Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
For more complete product information visit www.sylvania.com
300
I
N
D
E
X
Index (continued)
QUICKTRONIC® ELECTRONIC BALLASTS (cont.)
QUICKTRONIC® T5 Linear Fluorescent
T5HO Programmed Start, <10%THD
Discrete Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150
QUICKTRONIC® TT5 Compact Fluorescent
TT5 Instant Start, <20%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
TT5 Programmed Start, <10%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
QUICKTRONIC® T4 Compact Fluorescent
Programmed Start, <10%
Universal Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151
QUICKTRONIC® T8 Fluorescent
T8 Dimming, <10% THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152
QUICKTRONIC® T5 Linear Fluorescent - DIM
T5HO Dimming, <10% THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152
QUICKTRONIC® T8 Fluorescent - DIM
T8 Dimming, <10% THD - DALI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152
QUICKTRONIC® T5 Linear Fluorescent - DALI
T5HO Dimming, < 10% DALI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
T5 Dimming , <10% THD DALI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
QUICKTRONIC® T12 Fluorescent
T12 Instant Start, < 20%, 8 Foot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
T12HO Rapid Start, <20%THD, 8 Foot . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
T12 Rapid Start, <10% THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153-154
QUICKTRONIC® ICETRON® Universal Voltage . . . . . . . . . . . . . . . . . . . . . . .154
QUICKTRONIC® Metal Halide - Universal Voltage . . . . . . . . . . . . . . . . . . . . . .154
QUICKTRONIC® T2 Fluorescent Miniature - Universal Voltage . . . . . . . . . . .154
MAGNETIC FLUORESCENT BALLASTS
How to Read Product Information – Magnetic Fluorescent Ballasts . . . . . . .155
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156
Rapid Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Instant Start Slimline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Rapid Start HO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157-158
Rapid Start VHO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Preheat/Trigger Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
T9 Circline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
MAGNETIC HID BALLASTS
How to Read Product Information Magnetic HID Ballasts . . . . . . . . . . . . .160
METALARC® Metal Halide
Core & Coil Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161
Pulse Start Core & Coil Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161-163
F-Can . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Pulse Start F-Can . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Indoor Enclosed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163-164
LUMALUX® High Pressure Sodium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Pressure Sodium Reactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
High Pressure Sodium
Core & Coil Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164-165
F-Cans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165
Mercury
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165-166
Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
Ignitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167
Symbols and Footnotes for Electronic &
Magnetic Ballast Control Systems . . . . . . . . . . . . . . . . . . . .168-170
PHOTO-OPTIC SPECIALTY LAMPS
Photo-Optic Lamp Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171
Photo-Optic Halogen
Audiovisual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172-176
Studio, Theatre, TV & Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176-178
Large PAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178-179
Special Purpose Heat Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179
Aircraft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179-180
Airfield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180-181
Photo-Optic Discharge
HMI® Metal Halide
HMI® Single-Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
HMI® Double-Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
HMP® Metal Halide
HMP® Single-Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
HMP® Double-Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
HTI™ Metal Halide
HTI™ Single-Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185-186
HTI™ Double-Ended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
HTI™ with Dichroic Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
HSR® Metal Halide
HSR® with Outer Jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
HSD® Metal Halide
HSD® with Outer Jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
VIP® Video and Data Projection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
XBO® Xenon Short Arc
XBO® <= 450W Xenon Short Arc . . . . . . . . . . . . . . . . . . . . . . . .191-195
XBO® >450W Xenon Short Arc Cinema Film Projection . . . . .196-203
HBO® Mercury Short Arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204-207
HBO® Mercury Short Arc for Microlithography . . . . . . . . . . . . .208-215
Excimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
Xeradex™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
Spectral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
Photo-Optic Reference
Lamp Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217-219
Operating Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220
Photo-Optic Footnotes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221-224
Photo-Optic Warnings
Tungsten Halogen & Incandescent Photo-Optic Lamps . . . . . .225-226
Metal Halide Photo-Optic Lamps [HMI®, HMD®,
HMP®, HSD®, HSR®, HTI™] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226-228
VIP® Super High Pressure Mercury Lamps . . . . . . . . . . . . . . .228-230
XBO® High Pressure Xenon Lamps . . . . . . . . . . . . . . . . . . . . .230-231
HBO® High Pressure Mercury Lamps . . . . . . . . . . . . . . . . . . . .232-234
Photo-Optic Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235-238
OSRAM PLANON Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239
For more complete product information visit www.sylvania.com 301
I
N
D
E
X
Index (continued)
LED MODULES
OSRAM OPTO Semiconductors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .240
LED Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241
How to Read Product Information LED Modules . . . . . . . . . . . . . . . . . . . . .243
LED Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
LED Lamp Module Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
LINEARlight -Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245-246
COINlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247-249
LINEARlight -Flexible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250-251
OPTIC Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252
LED Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253
LINEARlight Colormix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254-255
BACKlight Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256-257
EFFECTlight Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258
MARKERlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259-263
OPTOTRONICS Dimming and RGB Control Modules . . . . . . . . . . . . . . . . . . .264
OPTOTRONICS LED Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265
LAMP AND BALLAST WARRANTIES
HID System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266-267
QUICK 60+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268-269
Magnetic Ballast Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270
LED System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271
MANUFACTURERS CROSS REFERENCE . . . . . . . . . .272-297
For more complete product information visit www.sylvania.com
302
N
O
T
E
S
FREQUENTLY ORDERED PRODUCTS:
For more complete product information visit www.sylvania.com 303
N
O
T
E
S
NOTES:
For more complete product information visit www.sylvania.com
304
N
O
T
E
S
NOTES:

Navigation menu