69 2576—05 Wiring Configuration HE150,HE250,HE300, HE100, HE200 HE300 Fan Mounting Location Addendum 2576
HE300 Fan Mounting Location Addendum 69-2576 Whole Home Fan-Powered Humidifier - TrueEASE | Honeywell
User Manual: Pdf HE300 Fan Mounting Location Addendum Whole Home Fan-Powered Humidifier - TrueEASE | Honeywell
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
Wiring Configuration INSTALLATION ADDENDUM ADVANCED MODELS (HE150/HE250/HE300) G OR W 2 OR C AIR PROVING DEVICE 3 HumidiPRO C R U U S S OUTDOOR SENSOR 1 POWER IN LEFT LEFT 1 HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN. HE300 USES A LINE CORD PLUG. 2 CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL. CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL. NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W. 3 USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION TO HUMIDIFY ANY TIME THE FAN IS OPERATING. M35152 Fig. 1. Wiring HumidiPRO (H6062) to humidify only with a call for Heat or Fan. FROM HUMIDITY CONTROL 1 POWER IN RIGHT LEFT 1 HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN. HE300 USES A LINE CORD PLUG. M35153 Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent control to program humidity calls with heat, cool, or on demand. 69-2576-05 WIRING CONFIGURATION 1 G (THERMOSTAT) HumidiPRO C R U U S S R G (FURNACE) 2 POWER IN OUTDOOR SENSOR RIGHT RIGHT 1 ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN. 2 HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN. HE300 USES A LINE CORD PLUG. M35154 Fig. 3. Wiring to force the HVAC system fan on whenever humidity is needed (on demand). 1 G (THERMOSTAT) HumidiPRO R G (FURNACE) C R U U S S AIR PROVING DEVICE 2 OUTDOOR SENSOR POWER IN LEFT RIGHT 1 ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN. 2 HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN. HE300 USES A LINE CORD PLUG. M35155 Fig. 4. Wiring to force fan on and prove airflow in the duct. 69-2576—05 2 WIRING CONFIGURATION BASIC MODELS (HE100/HE200) H8908 HUM/U WIRE HUM/U WIRE HUMIDIFIER OTHER WIRE(S) TO HVAC/FAN WHEN NECESSARY M24734 Fig. 5. Wiring connections on the H8908 humidistat. FAN CONTROL L1 (HOT) M35804 Fig. 6. Wiring H8908 humidistat. TRANSFORMER POWER SUPPLY 24V CONSTANT REQUIRED C R U U S S OUTDOOR SENSOR 2 L2 1 FURNACE FAN MOTOR HUMIDIFIER 1 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 24 VAC WIRING. M34570A Fig. 7. Wiring HumidiPRO with fan interlock. 3 69-2576—05 WIRING CONFIGURATION FAN CONTROL L1 (HOT) C R U U S S TRANSFORMER POWER SUPPLY 24V CONSTANT REQUIRED OUTDOOR SENSOR 2 L2 DPST SWITCHING RELAY 1 H L HUMIDIFIER 2-SPEED FAN MOTOR C 1 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 24 VAC WIRING. M34571A Fig. 8. Wiring HumidiPRO with 2-speed fan motor. 24V CONSTANT REQUIRED C R U U S S CURRENT SENSING RELAY AIR PRESSURE SWITCH/SAIL SWITCH OUTDOOR SENSOR 24V CONSTANT REQUIRED OUTDOOR SENSOR LO C HI L2 L1 1 (HOT) L2 HUMIDIFIER 1 C R U U S S L1 1 (HOT) HUMIDIFIER 1 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M34573A M34572A Fig. 9. Wiring HumidiPRO with current sensing relay. Fig. 10. Wiring HumidiPRO with air proving device. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com ® U.S. Registered Trademark © 2016 Honeywell International Inc. 69-2576—05 M.S. Rev. 01-16 Printed in United States
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res Author : Honeywell ECC Technical Communications Create Date : 1999:07:07 12:30:47Z Modify Date : 2016:01:14 17:35:52-06:00 Subject : Installation Addendum XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : FrameMaker 12.0.4 Metadata Date : 2016:01:14 17:35:52-06:00 Format : application/pdf Title : 69-2576—05 - Wiring Configuration HE150,HE250,HE300, HE100, HE200 Creator : Honeywell ECC Technical Communications Description : Installation Addendum Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:e13b9300-db5e-4735-af53-ed60f5e79256 Instance ID : uuid:9a21989a-502f-4aae-95b6-dce8d17bc06e Page Mode : UseOutlines Page Count : 4EXIF Metadata provided by EXIF.tools