Wiring Configuration
INSTALLATION ADDENDUM

ADVANCED MODELS (HE150/HE250/HE300)
G OR W

2

OR

C

AIR PROVING
DEVICE

3

HumidiPRO
C
R
U
U
S
S

OUTDOOR
SENSOR

1

POWER IN

LEFT
LEFT
1

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.

2

CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.

3

USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
M35152

Fig. 1. Wiring HumidiPRO (H6062) to humidify only with a call for Heat or Fan.

FROM
HUMIDITY
CONTROL

1

POWER IN

RIGHT
LEFT
1

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
M35153

Fig. 2. Wiring TrueIAQ, VisionPRO IAQ, or Prestige, using the intelligent
control to program humidity calls with heat, cool, or on demand.

69-2576-05

WIRING CONFIGURATION

1

G (THERMOSTAT)
HumidiPRO
C
R
U
U
S
S

R

G (FURNACE)

2

POWER IN

OUTDOOR
SENSOR

RIGHT
RIGHT
1

ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G.
IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION
AND ROUTE THROUGH HUMIDIFIER AS SHOWN.

2

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.

M35154

Fig. 3. Wiring to force the HVAC system fan on whenever humidity is needed (on demand).

1

G (THERMOSTAT)
HumidiPRO
R

G (FURNACE)

C
R
U
U
S
S

AIR PROVING
DEVICE

2
OUTDOOR
SENSOR

POWER IN

LEFT
RIGHT
1

ONLY NEEDED IF SYSTEM’S THERMOSTAT DOES NOT ISOLATE Y FROM G.
IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION
AND ROUTE THROUGH HUMIDIFIER AS SHOWN.

2

HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
M35155

Fig. 4. Wiring to force fan on and prove airflow in the duct.

69-2576—05

2

WIRING CONFIGURATION

BASIC MODELS (HE100/HE200)
H8908

HUM/U WIRE

HUM/U WIRE

HUMIDIFIER

OTHER WIRE(S)
TO HVAC/FAN
WHEN NECESSARY

M24734

Fig. 5. Wiring connections on the H8908 humidistat.

FAN CONTROL
L1
(HOT)

M35804

Fig. 6. Wiring H8908 humidistat.

TRANSFORMER

POWER
SUPPLY

24V CONSTANT
REQUIRED

C
R
U
U
S
S

OUTDOOR SENSOR

2

L2
1

FURNACE
FAN
MOTOR

HUMIDIFIER

1

PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

2

24 VAC WIRING.

M34570A

Fig. 7. Wiring HumidiPRO with fan interlock.

3

69-2576—05

WIRING CONFIGURATION

FAN CONTROL
L1
(HOT)

C
R
U
U
S
S

TRANSFORMER

POWER
SUPPLY

24V CONSTANT
REQUIRED

OUTDOOR SENSOR

2

L2

DPST
SWITCHING
RELAY

1

H

L

HUMIDIFIER

2-SPEED
FAN MOTOR

C

1

PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

2

24 VAC WIRING.

M34571A

Fig. 8. Wiring HumidiPRO with 2-speed fan motor.

24V CONSTANT
REQUIRED

C
R
U
U
S
S

CURRENT
SENSING
RELAY

AIR PRESSURE
SWITCH/SAIL
SWITCH

OUTDOOR SENSOR

24V CONSTANT
REQUIRED

OUTDOOR SENSOR

LO
C

HI

L2

L1 1
(HOT)

L2
HUMIDIFIER

1

C
R
U
U
S
S

L1 1
(HOT)
HUMIDIFIER

1

PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
M34573A

M34572A

Fig. 9. Wiring HumidiPRO with current sensing relay.

Fig. 10. Wiring HumidiPRO with air proving device.

Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
customer.honeywell.com

® U.S. Registered Trademark
© 2016 Honeywell International Inc.
69-2576—05 M.S. Rev. 01-16
Printed in United States



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Assemble, Print high-res
Author                          : Honeywell ECC Technical Communications
Create Date                     : 1999:07:07 12:30:47Z
Modify Date                     : 2016:01:14 17:35:52-06:00
Subject                         : Installation Addendum
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : FrameMaker 12.0.4
Metadata Date                   : 2016:01:14 17:35:52-06:00
Format                          : application/pdf
Title                           : 69-2576—05 - Wiring Configuration HE150,HE250,HE300, HE100, HE200
Creator                         : Honeywell ECC Technical Communications
Description                     : Installation Addendum
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:e13b9300-db5e-4735-af53-ed60f5e79256
Instance ID                     : uuid:9a21989a-502f-4aae-95b6-dce8d17bc06e
Page Mode                       : UseOutlines
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu