Thermal-Magnetic Molded Case
100 Ampere Frame
Class 650
qFCL 2-pole circuit breaker built using 3-pole module.
jFCL circuit breakers are not rated for 250 Vdc.
F Frame – 100 A, Thermal-Magnetic (240 Vac)
Continuous
Current Rating
@ 40° C
AC Magnetic
Trip Settings Standard Interrupting Terminal
Wire
Range
Hold Trip Catalog Number Price
1-Pole, 120 Vac
15
20
25
30
275
275
275
275
600
600
600
600
FAL12015
FAL12020
FAL12025
FAL12030
$126.
126.
126.
126.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL12035
FAL12040
FAL12045
FAL12050
FAL12060
FAL12070
FAL12080
FAL12090
FAL12100
126.
126.
126.
126.
126.
166.
166.
166.
166.
AL100FA
#14-#1/0 AWG Cu
or #12-#1/0 AWG Al
2-Pole, 240 Vac
15
20
25
30
275
275
275
275
600
600
600
600
FAL22015
FAL22020
FAL22025
FAL22030
$211.
211.
211.
211.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL22035
FAL22040
FAL22045
FAL22050
FAL22060
FAL22070
FAL22080
FAL22090
FAL22100
211.
211.
211.
211.
211.
345.
345.
345.
345.
AL100FA
#14-#1/0 AWG Cu
or #12-#1/0 AWG Al
3-Pole, 240 Vac
15
20
25
30
275
275
275
275
600
600
600
600
FAL32015
FAL32020
FAL32025
FAL32030
$314.
314.
314.
314.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL32035
FAL32040
FAL32045
FAL32050
FAL32060
FAL32070
FAL32080
FAL32090
FAL32100
314.
314.
314.
314.
314.
447.
447.
447.
447.
AL100FA
#14-#1/0 AWG Cu
or #12-#1/0 AWG Al
F Frame – 100 A, Thermal-Magnetic (480 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip Settings Standard
Interrupting Extra High
Interrupting Terminal
Wire
Range FC Lugs
Hold Trip Catalog
Number Price Catalog
Number Price
1-Pole, 277 Vac, 125 Vdc
15
20
25
30
275
275
275
275
600
600
600
600
FAL14015
FAL14020
FAL14025
FAL14030
$159.
159.
159.
159.
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al . . .
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL14035
FAL14040
FAL14045
FAL14050
FAL14060
FAL14070
FAL14080
FAL14090
FAL14100
159.
159.
159.
159.
159.
198.
198.
198.
198.
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
AL100FA
#14-#1/0 AWG Cu or
#12-#1/0 AWG Al . . .
2-Pole, 480 Vac, 250 Vdcjq
15
20
25
30
275
275
275
275
600
600
600
600
FAL24015
FAL24020
FAL24025
FAL24030
$387.
387.
387.
387.
FCL24015
FCL24020
FCL24025
FCL24030
$ 919.
919.
919.
919.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
CU30FA4
1-#14-#10 AWG
CU only
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL24035
FAL24040
FAL24045
FAL24050
FAL24060
FAL24070
FAL24080
FAL24090
FAL24100
387.
387.
387.
387.
387.
500.
500.
500.
500.
FCL24035
FCL24040
FCL24045
FCL24050
FCL24060
FCL24070
FCL24080
FCL24090
FCL24100
919.
919.
919.
919.
919.
1131.
1131.
1131.
1131.
AL100FA
#14-#1/0 AWG Cu or
#12-#1/0 AWG Al
AL100FA4
1-#14-#3 AWG CU
or
1-#12-#1 AWG AL
3-Pole, 480 Vac, 250 Vdcj
15
20
25
30
275
275
275
275
600
600
600
600
FAL34015
FAL34020
FAL34025
FAL34030
$496.
496.
496.
496.
FCL34015
FCL34020
FCL34025
FCL34030
$1149.
1149.
1149.
1149.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
CU30FA4
1-#14-#10 AWG
CU only
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL34035
FAL34040
FAL34045
FAL34050
FAL34060
FAL34070
FAL34080
FAL34090
FAL34100
496.
496.
496.
496.
496.
587.
587.
587.
587.
FCL34035
FCL34040
FCL34045
FCL34050
FCL34060
FCL34070
FCL34080
FCL34090
FCL34100
1149.
1149.
1149.
1149.
1149.
1413.
1413.
1413.
1413.
AL100FA
#14-#1/0 AWG Cu or
#12-#1/0 AWG Al
AL100FA4
1-#14-#3 AWG CU
or
1-#12-#1 AWG AL
FAL
1-pole
15-100 Amperes
FAL/FHL
2-pole
15-100 Amperes
FAL/FHL/FCL
3-pole
15-100 Amperes
I-LINE is a Registered Trademark of Square D Company or related companies.
Accessories ...........................................................................Pages 6-37–6-39
Optional Lugs ........................................................................Pages 6-40, 6-41
Dimensions ...............................................................................Page 6-45, 6-46
Enclosures ..............................................................................Pages 6-47–6-50
Catalog Numbering System .............................................................. Page 6-23
Interrupting Ratings (kA)
FAL240 FAL480 FCL
240 V 10 18 (1P), 25 (2, 3P) 100
480 V . . . 18 65
600 V . . . . . . . . .
Thermal-magnetic molded case circuit breakers
shown on Pages 6-21 thru 6-25 are permanent trip UL
Listed, CSA certified, IEC rated, and also meet the
requirements of Federal Specification W–C–375B/GEN
as indicated on Pages 6-4 thru 6-8. For I-LINE® molded
case circuit breakers, see listings on Pages 8-24–8-34.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-22 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
DE2A Discount
Schedule
Thermal-Magnetic Molded Case
100, 225 Ampere Frame
Class 525, 650, 734, 820
aAccessories and replacement lugs are not available on the Q2 circuit breaker. Lugs for the Q2 circuit breakers accept 1-#4 AWG-300
kcmil.
k2-pole Q2 is 10 kA at 120/240 Vac.
qGJL is rated 18 kA at 600Y/347 Vac.
F Frame – 100 A, Thermal-Magnetic (600 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip Settings Standard Interrupting High Interrupting Current Limiting Terminal
Wire
Range
Hold Trip Catalog
Number Price Catalog
Number Price Catalog
Number Price
1-Pole, 277 Vac, 125 Vdc
15
20
25
30
275
275
275
275
600
600
600
600
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
FHL16015
FHL16020
FHL16025
FHL16030
$287.
287.
287.
287.
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
FHL16035
FHL16040
FHL16045
FHL16050
FHL16060
FHL16070
FHL16080
FHL16090
FHL16100
287.
287.
287.
287.
287.
323.
323.
323.
323.
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
AL100FA
#14-#1/0 AWG Cu or
#12-#1/0 AWG Al
2-Pole, 600 Vac, 250 Vdc
15
20
25
30
275
275
275
275
600
600
600
600
FAL26015
FAL26020
FAL26025
FAL26030
$447.
447.
447.
447.
FHL26015
FHL26020
FHL26025
FHL26030
$738.
738.
738.
738.
. . .
FIL26020
. . .
FIL26030
. . .
$1671.
. . .
1671.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL26035
FAL26040
FAL26045
FAL26050
FAL26060
FAL26070
FAL26080
FAL26090
FAL26100
447.
447.
447.
447.
447.
565.
565.
565.
565.
FHL26035
FHL26040
FHL26045
FHL26050
FHL26060
FHL26070
FHL26080
FHL26090
FHL26100
738.
738.
738.
738.
738.
859.
859.
859.
859.
. . .
FIL26040
. . .
FIL26050
FIL26060
FIL26070
FIL26080
FIL26090
FIL26100
. . .
1671.
. . .
1671.
1671.
1671.
1671.
1671.
1671.
AL100FA
#14-#1/0 AWG Cu or
#12-#1/0 AWG Al
3-Pole, 600 Vac, 250 Vdc
15
20
25
30
275
275
275
275
600
600
600
600
FAL36015
FAL36020
FAL36025
FAL36030
$575.
575.
575.
575.
FHL36015
FHL36020
FHL36025
FHL36030
$862.
862.
862.
862.
. . .
FIL36020
. . .
FIL36030
. . .
$2092.
. . .
2092.
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
35
40
45
50
60
70
80
90
100
400
400
400
400
800
800
800
900
900
850
850
850
850
1450
1450
1450
1700
1700
FAL36035
FAL36040
FAL36045
FAL36050
FAL36060
FAL36070
FAL36080
FAL36090
FAL36100
575.
575.
575.
575.
575.
708.
708.
708.
708.
FHL36035
FHL36040
FHL36045
FHL36050
FHL36060
FHL36070
FHL36080
FHL36090
FHL36100
862.
862.
862.
862.
862.
978.
978.
978.
978.
. . .
FIL36040
. . .
FIL36050
FIL36060
FIL36070
FIL36080
FIL36090
FIL36100
. . .
2092.
. . .
2092.
2092.
2092.
2092.
2092.
2092.
AL100FA
#14-#1/0 AWG Cu or
#12-#1/0 AWG Al
POWERPACT® G Frame – 100 A, Thermal-Magnetic (600Y/347 Vac)
Continuous Current
Rating @ 40° C AC Magnetic Trip Settings J Interrupting Terminal Wire
Range
Hold Trip Catalog Number Price
3-Pole, Vac, Vdc
15
20
30
40
50
60
70
80
100
600
600
600
600
800
800
800
800
800
1200
1200
1200
1200
1400
1400
1400
1400
1400
GJL36015
GJL36020
GJL36030
GJL36040
GJL36050
GJL36060
GJL36070
GJL36080
GJL36100
$1264.
1264.
1264.
1264.
1264.
1264.
1554.
1554.
1554.
#14-#1/0 AWG Cu
#8-#1/0 AWG Al
Q Framea – 225 A, Thermal-Magnetic (240 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip Settings Standard Interrupting High Interrupting Extra High Interrupting
Hold Trip Catalog
Number Price Catalog
Number Price Catalog
Number Price
2-Pole, 240 Vac
100
110
125
150
175
200
225
1400
1400
1400
1400
1400
1400
1400
2400
2400
2400
2400
2400
2400
2400
Q2L2100k
Q2L2110k
Q2L2125k
Q2L2150k
Q2L2175k
Q2L2200k
Q2L2225k
$301.
301.
301.
301.
301.
301.
301.
Q2L2100H
Q2L2110H
Q2L2125H
Q2L2150H
Q2L2175H
Q2L2200H
Q2L2225H
$726.
726.
726.
726.
726.
726.
726.
Q2LH2100
Q2LH2110
Q2LH2125
Q2LH2150
Q2LH2175
Q2LH2200
Q2LH2225
$966.
966.
966.
966.
966.
966.
966.
3-Pole, 240 Vac
100
110
125
150
175
200
225
1400
1400
1400
1400
1400
1400
1400
2400
2400
2400
2400
2400
2400
2400
Q2L3100
Q2L3110
Q2L3125
Q2L3150
Q2L3175
Q2L3200
Q2L3225
$792.
792.
792.
792.
792.
792.
792.
Q2L3100H
Q2L3110H
Q2L3125H
Q2L3150H
Q2L3175H
Q2L3200H
Q2L3225H
$1132.
1132.
1132.
1132.
1132.
1132.
1132.
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
Interrupting Ratings (kA)
FAL FHL FIL GJL Q2L Q2L-H Q2LH
240 V 25 25 (1P:35-100A), 65 (2, 3P) 200 100 10k22 42
480 V 18 25 (2, 3P) 200 65 . . . . . . . . .
600 V 14 18 (2, 3P) 100 18q. . . . . . . . .
Q2L
2- and 3-pole
100-225 Amperes
FIL36100
GJL 3-pole
circuit breaker
Accessories ................................................. Pages 6-37–6-39
Optional Lugs .............................................. Pages 6-40, 6-41
Dimensions...................................................... Page 6-45, 6-46
Enclosures..................................................... Pages 6-47–6-50
Catalog Numbering System......................................Page 6-23
POWERPACT is a Registered Trademark of Square D Company or related companies.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-23
DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Catalog Numbering System for Thermal-Magnetic Molded Case Circuit Breakers
FA L 3 6 100 2100
Circuit Breaker
Family
FY
EH
Q4
FA, FH, FC, FI
KA, KH, KC, KI
LA, LH, LC, LI
MA, MH
NA, NC
Note: “A” is replaced by letter “H” for high interrupting circuit
breaker. “A” is replaced by letter “C” for extra high interrupting
circuit breaker. “A” is replaced by the letter “I” for current-limiting
circuit breakers.
No Letter – I-LINE F – Terminal pads only (No lugs)
L – Lugs on both ends P – Lugs OFF end only
1 – 1-pole 2 – 2-pole 3 – 3-pole
2 – 240 Vac 4 – 480 Vac 6 – 600 Vac
015-1200 – Ampere rating
000M-0000M – Molded case switch (automatic)
Special Features
A, B, C – I-LINE phase connections
XXXX – Factory-installed accessories
Thermal-Magnetic Molded Case
250 Ampere Frame
Class 655, 825
qUL magnetic trip setting tolerances are ±25% (low) and ±20% (high) from nominal values shown.
K Frame – 250 A, Thermal-Magnetic (600 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip SettingsqStandard
Interrupting High
Interrupting Current
Limiting Terminal
Wire
Range
Low High Catalog
Number Price Catalog
Number Price Catalog
Number Price
2-Pole, 600 Vac, 250 Vdc
70
80
90
100
110
125
150
175
350
400
450
500
550
625
750
875
700
800
900
1000
1100
1250
1500
1750
KAL26070
KAL26080
KAL26090
KAL26100
KAL26110
KAL26125
KAL26150
KAL26175
$1315.
1315.
1315.
1315.
1315.
1315.
1315.
1315.
KHL26070
KHL26080
KHL26090
KHL26100
KHL26110
KHL26125
KHL26150
KHL26175
$3072.
3072.
3072.
3072.
3072.
3072.
3072.
3072.
. . .
. . .
. . .
. . .
KIL26110
KIL26125
KIL26150
KIL26175
. . .
. . .
. . .
. . .
$3922.
3922.
3922.
3922.
AL250KA
1-#4 AWG-350 kcmil
200
225
250
1000
1125
1250
2000
2250
2500
KAL26200
KAL26225
KAL26250
1315.
1315.
2286.
KHL26200
KHL26225
KHL26250
3072.
3072.
4039.
. . .
. . .
. . .
. . .
. . .
. . .
200
225
250
1000
1125
1250
2000
2250
2500
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
KIL26200
KIL26225
KIL26250
3922.
3922.
4586.
AL250KI
1-#1/0 AWG-350 kcmil
3-Pole, 600 Vac, 250 Vdc
70
80
90
100
110
125
150
175
350
400
450
500
550
625
750
875
700
800
900
1000
1100
1250
1500
1750
KAL36070
KAL36080
KAL36090
KAL36100
KAL36110
KAL36125
KAL36150
KAL36175
$1650.
1650.
1650.
1650.
1650.
1650.
1650.
1650.
KHL36070
KHL36080
KHL36090
KHL36100
KHL36110
KHL36125
KHL36150
KHL36175
$3713.
3713.
3713.
3713.
3713.
3713.
3713.
3713.
. . .
. . .
. . .
. . .
KIL36110
KIL36125
KIL36150
KIL36175
. . .
. . .
. . .
. . .
$4923.
4923.
4923.
4923.
AL250KA
1-#4 AWG-350 kcmil
200
225
250
1000
1125
1250
2000
2250
2500
KAL36200
KAL36225
KAL36250
1650.
1650.
2751.
KHL36200
KHL36225
KHL36250
3713.
3713.
4824.
. . .
. . .
. . .
. . .
. . .
. . .
200
225
250
1000
1125
1250
2000
2250
2500
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
KIL36200
KIL36225
KIL36250
4923.
4923.
5766.
AL250KI
1-#1/0 AWG-350 kcmil
K Frame – 250 A, Thermal-Magnetic (480 Vac)
Continuous
Current Rating
@ 40° C
AC Magnetic
Trip SettingsqExtra High Interrupting Terminal
Wire
Range
Low High Catalog Number Price
2-Pole, 480 Vac
110
125
150
175
550
625
750
875
1100
1250
1500
1750
KCL24110
KCL24125
KCL24150
KCL24175
$3465.
3465.
3465.
3465.
AL250KA
1-#4 AWG-350 kcmil
200
225
250
1000
1125
1250
2000
2250
2500
KCL24200
KCL24225
KCL24250
3465.
3465.
4248.
AL250KI
1-#1/0 AWG-350 kcmil
3-Pole, 480 Vac
110
125
150
175
550
625
750
875
1100
1250
1500
1750
KCL34110
KCL34125
KCL34150
KCL34175
4331.
4331.
4331.
4331.
AL250KA
1-#4 AWG-350 kcmil
200
225
250
1000
1125
1250
2000
2250
2500
KCL34200
KCL34225
KCL34250
4331.
4331.
5314.
AL250KI
1-#1/0 AWG-350 kcmil
Interrupting Ratings (kA)
KAL KHL KCL KIL
240 V 42 65 100 200
480 V 25 35 65 200
600 V 22 25 . . . 100
Accessories ..........................................................................Pages 6-37–6-39
Optional Lugs ........................................................................Pages 6-40, 6-41
Dimensions...............................................................................Page 6-45, 6-46
Enclosures..............................................................................Pages 6-47–6-50
KAL/KHL
2- and 3-pole
70-250 Amperes
KIL36250
I-LINE is a Registered Trademark of Square D Company or related companies.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-24 DE2A Discount
Schedule 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Thermal-Magnetic Molded Case
400, 600, 1000 Ampere Frame
Class 660, 665, 735, 830
Q4 Frame – 400 A, Thermal-Magnetic (240 Vac)
Continuous
Current Rating
@ 40° C
AC Magnetic
Trip SettingsqStandard Interrupting Terminal
Wire
Range
Low High Catalog Number Price
2-Pole, 240 Vac
250
300
350
400
1250
1500
1750
2000
2500
3000
3500
4000
Q4L2250
Q4L2300
Q4L2350
Q4L2400
$2013.
2013.
2013.
2013.
AL400LA
1-#1 AWG-600 kcmil or
2-#1 AWG-250 kcmil
3-Pole, 240 Vac
250
300
350
400
1250
1500
1750
2000
2500
3000
3500
4000
Q4L3250
Q4L3300
Q4L3350
Q4L3400
$2432.
2432.
2432.
2432.
AL400LA
1-#1 AWG-600 kcmil or
2-#1 AWG-250 kcmil
L Frame – 400 A, Thermal-Magnetic (600 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip SettingsqStandard Interrupting High Interrupting Terminal
Wire
Range
Low High Catalog
Number Price Catalog
Number Price
2-Pole, 600 Vac, 250 Vdc
125
150
175
200
225
250
625
750
875
1000
1125
1250
1250
1500
1750
2000
2250
2500
LAL26125
LAL26150
LAL26175
LAL26200
LAL26225
LAL26250
$2417.
2417.
2417.
2417.
2417.
2417.
LHL26125
LHL26150
LHL26175
LHL26200
LHL26225
LHL26250
$4039.
4039.
4039.
4039.
4039.
4039.
AL400LA
1-#1 AWG-600 kcmil
or
2-#1 AWG-250 kcmil
300
350
400
1500
1750
2000
3000
3500
4000
LAL26300
LAL26350
LAL26400
2417.
2417.
2417.
LHL26300
LHL26350
LHL26400
4039.
4039.
4039.
3-Pole, 600 Vac, 250 Vdc
125
150
175
200
225
250
625
750
875
1000
1125
1250
1250
1500
1750
2000
2250
2500
LAL36125
LAL36150
LAL36175
LAL36200
LAL36225
LAL36250
$2932.
2932.
2932.
2932.
2932.
2932.
LHL36125
LHL36150
LHL36175
LHL36200
LHL36225
LHL36250
$4824.
4824.
4824.
4824.
4824.
4824.
AL400LA
1-#1 AWG-600 kcmil
or
2-#1 AWG-250 kcmil
300
350
400
1500
1750
2000
3000
3500
4000
LAL36300
LAL36350
LAL36400
2932.
2932.
2932.
LHL36300
LHL36350
LHL36400
4824.
4824.
4824.
L Frame – 600 A, Thermal-Magnetic (600 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip SettingsqExtra High InterruptingcCurrent Limiting Terminal
Wire
Range
Low High Catalog
Number Price Catalog
Number Price
2-Pole, 600 Vac
300
350
400
1500
1750
2000
3000
3500
4000
LCL26300
LCL26350
LCL26400
$4749.
4749.
4749.
LIL26300
LIL26350
LIL26400
$5463.
5463.
5463. AL600LI5
2-#4/0 AWG-
500 kcmil
450
500
600
2250
2500
3000
4500
5000
5400
LCL26450
LCL26500
LCL26600
4967.
4967.
4967.
LIL26450
LIL26500
LIL26600
7969.
7969.
7969.
3-Pole, 600 Vac
300
350
400
1500
1750
2000
3000
3500
4000
LCL36300
LCL36350
LCL36400
$5277.
5277.
5277.
LIL36300
LIL36350
LIL36400
$6071.
6071.
6071. AL600LI5
2-#4/0 AWG-
500 kcmil
450
500
600
2250
2500
3000
4500
5000
5400
LCL36450
LCL36500
LCL36600
5518.
5518.
5518.
LIL36450
LIL36500
LIL36600
8856.
8856.
8856.
M Frame – 1000 A, Thermal-Magnetic (600 Vac)
Cont.
Current
Rating
@ 40° C
AC Magnetic
Trip SettingsqStandard Interrupting High Interrupting Terminal
Wire
Range
Low High Catalog
Number Price Catalog
Number Price
2-Pole, 600 Vac, 250 Vdc
300
350
400
450
500
600
700
800
900
1000
1500
1750
2000
2250
2500
3000
3500
4000
4500
5000
3000
3500
4000
4500
5000
6000
7000
8000
9000
10000
MAL26300
MAL26350
MAL26400
MAL26450
MAL26500
MAL26600
MAL26700
MAL26800
MAL26900
MAL261000
$3784.
3784.
3784.
3784.
3784.
3784.
4901.
4901.
6991.
6991.
MHL26300
MHL26350
MHL26400
MHL26450
MHL26500
MHL26600
MHL26700
MHL26800
MHL26900
MHL261000
$4970.
4970.
4970.
4970.
4970.
4970.
6131.
6131.
7753.
7753.
AL900MA
3-#3/0 AWG-
500 kcmil
1200 5500 12000 MAL261200 8221. MHL261200 9684. AL1000MAt
4-#1/0 AWG-
350 kcmil
3-Pole, 600 Vac, 250 Vdc
300
350
400
450
500
600
700
800
900
1000
1500
1750
2000
2250
2500
3000
3500
4000
4500
5000
3000
3500
4000
4500
5000
6000
7000
8000
9000
10000
MAL36300
MAL36350
MAL36400
MAL36450
MAL36500
MAL36600
MAL36700
MAL36800
MAL36900
MAL361000
$4800.
4800.
4800.
4800.
4800.
4800.
6303.
6303.
8067.
8067.
MHL36300
MHL36350
MHL36400
MHL36450
MHL36500
MHL36600
MHL36700
MHL36800
MHL36900
MHL361000
$6004.
6004.
6004.
6004.
6004.
6004.
7544.
7544.
8938.
8938.
AL900MA
3-#3/0 AWG-
500 kcmil
1200 5500 12000 MAL361200 9591. MHL361200 11182. AL1000MAt
4-#1/0 AWG-
350 kcmil
M Frame – 1000 A, Thermal-Magnetic (600 Vac) (Continued)
Cont.
Current
Rating
@ 40° C
AC Magnetic
Trip SettingsqStandard Interrupting High Interrupting Terminal
Wire
Range
Low High Catalog
Number Price Catalog
Number Price
LAL/LHL
2- and 3-pole
125-400 Amperes
MAL/MHL
2- and 3-pole
300-1000 Amperes
LIL36600
Accessories ..........................................................................Pages 6-37–6-39
Optional Lugs ....................................................................... Pages 6-40, 6-41
Dimensions...............................................................................Page 6-45, 6-46
Enclosures.............................................................................. Pages 6-47–6-50
Catalog Numbering System.............................................................. Page 6-23
Interrupting Ratings (kA)
Q4L LAL LHL LCL LIL MAL MHL
240 V 25 42 65 100 200 42 65
480 V . . . 30 35 65 200 30 65
600 V . . . 22 25 35 100 22 25
qUL magnetic trip setting tolerances are ±25% (low) and ±20% (high) from nominal values shown.
cUse only in tested and listed enclosures.
tThe AL1000MA lug is the only lug available for the 1200 Ampere MA and MH circuit breaker.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-25
DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Thermal-Magnetic Molded Case
1200, 2000, 2500 Ampere Frames
Class 670, 675, 676
jPrice does not include lugs. See Pages 6-40 and 6-41 for catalog numbers and prices.
qUL magnetic trip setting tolerances are ±25% (Low) and ±20% (High) from the nominal values shown.
N Frame – 1200 A, Thermal-Magnetic (600 Vac)
Continuous
Current
Rating
@ 40° C
AC Magnetic
Trip SettingsqStandard Interrupting Extra High Interrupting Terminal
Wire
Range
Low High Catalog Number Price Catalog Number Price
2-Pole, 600 Vac
600
700
800
900
1000
1200
4000
4000
4000
5000
5000
5000
8000
8000
8000
10000
10000
10000
NAL26600
NAL26700
NAL26800
NAL26900
NAL261000
NAL261200
$11024.
11024.
11024.
11024.
11024.
11024.
NCL26600
NCL26700
NCL26800
NCL26900
NCL261000
NCL261200
$12694.
12694.
12694.
12694.
12694.
12694.
AL1200NE6
4-#3/0 AWG-600 kcmil
3-Pole, 600 Vac
600
700
800
900
1000
1200
4000
4000
4000
5000
5000
5000
8000
8000
8000
10000
10000
10000
NAL36600
NAL36700
NAL36800
NAL36900
NAL361000
NAL361200
$12094.
12094.
12094.
12094.
12094.
12094.
NCL36600
NCL36700
NCL36800
NCL36900
NCL361000
NCL361200
$13620.
13620.
13620.
13620.
13620.
13620.
AL1200NE6
4-#3/0 AWG-600 kcmil
P Frame – 2000 and 2500 A, Thermal-Magnetic (600 Vac)
Ampere
Rating
AC
Magnetic
Trip
Settings
Amperesq
2-pole – 600 Vac 3-pole – 600 Vac
Frame Only Rating
Columns
Two Per Kit Total
Pricej
Frame Only Rating
Columns
Three Per Kit Total
Pricej
Low High Catalog
No. Price Kit
Catalog
No.
Kit
Price Catalog
No. Price Kit
Catalog
No.
Kit
Price
2000 Ampere Frame
PAF Standard Interrupting – Complete Circuit Breaker Requires Frame and Rating Columns
600
700
800
1000
1200
1400
1600
1800
2000
3200
3200
3200
3500
3500
4500
5000
6500
8000
9000
9000
9000
9000
9000
9000
10000
11000
12000
PAF2026 $10809.
PA2600RC
PA2700RC
PA2800RC
PA21000RC
PA21200RC
PA21400RC
PA21600RC
PA21800RC
PA22000RC
$232.
232.
232.
232.
232.
232.
232.
232.
232.
$11041. PAF2036 $13855.
PA3600RC
PA3700RC
PA3800RC
PA31000RC
PA31200RC
PA31400RC
PA31600RC
PA31800RC
PA32000RC
$350.
350.
350.
350.
350.
350.
350.
350.
350.
$14205.
PHF High Interrupting – Complete Circuit Breaker Requires Frame and Rating Columns
600
700
800
1000
1200
1400
1600
1800
2000
3200
3200
3200
3500
3500
4500
5000
6500
8000
9000
9000
9000
9000
9000
9000
10000
11000
12000
PHF2026 $12397.
PA2600RC
PA2700RC
PA2800RC
PA21000RC
PA21200RC
PA21400RC
PA21600RC
PA21800RC
PA22000RC
$232.
232.
232.
232.
232.
232.
232.
232.
232.
$12629. PHF2036 $15347.
PA3600RC
PA3700RC
PA3800RC
PA31000RC
PA31200RC
PA31400RC
PA31600RC
PA31800RC
PA32000RC
$350.
350.
350.
350.
350.
350.
350.
350.
350.
$15697.
2500 Ampere Frame
PCF High Interrupting – Complete Circuit Breaker Requires Frame and Rating Columns
1600
1800
2000
2500
6000
6000
6000
8000
12000
12000
12000
14000
PCF2526 $19945.
PC21600RC
PC21800RC
PC22000RC
PC22500RC
$232.
232.
232.
232.
$20177. PCF2536 $24655.
PC31600RC
PC31800RC
PC32000RC
PC32500RC
$350.
350.
350.
350.
$25005.
Interrupting Ratings (kA)
NAL NCL PAF PHF PCF
240 V 100 125 65 125 125
480 V 50 100 50 100 100
600 V 25 65 42 65 65
Accessories .............................................................................................................................................Pages 6-37–6-39
Optional Lugs ...........................................................................................................................................Pages 6-40, 6-41
Dimensions..................................................................................................................................................Page 6-45, 6-46
Enclosures.................................................................................................................................................Pages 6-47–6-50
Catalog Numbering System................................................................................................................................. Page 6-23
NAL/NCL
Two- and Three-Pole
600-1200 Amperes
PAF/PHF
Two- and Three-Pole
600-2000 Amperes
PALTB
PAF and PHF circuit breakers can be bus or cable connected. For cable
connections, optional terminal pad kit PALTB or equivalent bus structure is
required. Each PALTB kit contains terminal pads for one end of the circuit
breaker only and has provisions for mounting a maximum of six lugs per
phase. Order lugs separately. See Pages 6-40 and 6-41.
PCF circuit breakers are supplied with terminal pads for both ends of the
circuit breaker. The supplied terminal pads or equivalent bus structure must
be used for bus or cable connections. Terminal pads have provisions for
mounting a maximum of eight lugs per phase. Order lugs separately. See
Pages 6-40 and 6-41.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-26 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
MAG-GARD® Motor Circuit Protectors
Selection Table
Class 680
MAG-GARD is a Registered Trademark of Square D Company.
Adjustable instantaneous-trip circuit breakers are
intended for use in combination with motor starters with
overload relays for the protection of motor circuits from
short circuits. Other specific applications include rectifiers
and resistance welders. These circuit breakers contain a
magnetic trip element in each pole with the trip point
adjustable from the front. Interrupting ratings are
determined by testing the instantaneous trip circuit
breakers in combination with a contactor and overload
relay.
Select instantaneous trip circuit breakers as follows:
1. This selection table is suitable for motors, other than
NEMA Design E, with locked-rotor indicating code
letters per NEC Table 430-7 (b) as follows:
For other motors order a special thermal magnetic circuit
breaker with magnetic trip settings for the specific motor –
specify motor horsepower, voltage, frequency, full-load
current and code letter or locked rotor current.
2. Determine motor HP rating from the motor nameplate.
3. Refer to the table at right and select an instantaneous
trip circuit breaker with an Ampere rating
recommended for the HP and voltage involved.
4. Select an adjustable trip setting of at least 700%, not
to exceed 1300%, of the motor full-load Amperes.
(FLA) for other than Design E motors. For Design E
motors, select an adjustable trip setting of at least
1100% not to exceed 1700% of FLA.
5. The NEC 1300% maximum setting may be
inadequate for instantaneous trip circuit breakers to
withstand current surges typical of the magnetization
current of autotransformer type reduced voltage
starters, or open transition wye-delta starters during
transfer from “start” to “run”, constant HP multi-speed
motors, and motors labeled “high efficiency”. Select
thermal-magnetic circuit breakers from Page 6-28 for
those applications.
6. Part-winding motors, per NEC 430-3, should have two
circuit breakers selected from the above at not more
than one half the allowable trip setting for the
horsepower rating. The two circuit breakers should
operate simultaneously as a disconnecting means per
NEC 430-103.
aMotor full-load currents are taken from Table 430-150
of the NEC. Select wire and circuit breakers on basis of
horsepower rather than nameplate full-load current per
NEC Article 430-6 (a) for general motor applications.
Do not use these values to select overload relay
thermal units. See Digest 172, Page 13-15–13-19 for
selection of thermal units when actual full load is not
known. The voltages listed are rated motor voltages.
Corresponding nominal system voltages are 200 to
208, 220 to 240, 440 to 480 and 550 to 600 volts.
qSee NEC Section 430-52(a) for breaker settings above
700%.
cIf due to motor starting characteristics, trip settings at
the 1300% maximum permitted level are needed, the
next size MAG-GARD circuit breaker should be
chosen.
jOnly MIN and MAX settings are shown, intermediate
settings are available on all circuit breakers.
Horsepower Motor Code Letters
12 or less A-L
34 to 112A-K
2 to 3 A-J
5 to 25 A-H
30 to 125 A-G
150 or more A-F
Based on NEC Article 430-52 and NEC Table 430-150.
See Page 6-27 for a complete listing of Square D Adjustable Instantaneous Trip Circuit Breakers.
HP Ratings of Induction
Type Squirrel-cage and
Wound Rotor Motors a
Full
Load
Amperes
MAG-GARD
Circuit Breaker
Catalog No.
Magnetic Trip
Settings jGJL Family
MAG-GARD
Circuit Breaker
Catalog No.
Magnetic Trip
Settings j
Three-Phase 60 Hz ac
200
Volts 230
Volts 460
Volts 575
Volts MIN MAX MIN MAX
120.8 FAL36003-11Ma1000% 3500% GJL36003M01q1100% 4100%
121 FAL36003-11Ma800% 2800% GJL36003M01q900% 3300%
341.1 FAL36003-11M 700% 2500% GJL36003M01q800% 3000%
341 1.4 FAL36003-11M 600% 2000% GJL36003M01 600% 2400%
1 1.8 FAL36003-11M 400% 1600% GJL36003M01 500% 1800%
122 FAL36003-11M 400% 1400% GJL36003M01 500% 1700%
1
122.1 FAL36003-11M 400% 1300% GJL36003M01 400% 1600%
1 2.3 FAL36003-11Mc300% 1200% GJL36003M01 400% 1400%
1122.6 FAL36007-12M 700% 2700% GJL36003M01 300% 1300%
2 2.7 FAL36007-12M 700% 2600% GJL36003M01c300% 1200%
342.8 FAL36007-12M 600% 2500% GJL36003M01c300% 1200%
3 3.2 FAL36007-12M 600% 2200% GJL36007M02 700% 2400%
2 3.4 FAL36007-12M 500% 2100% GJL36007M02 600% 2300%
1 3.6 FAL36007-12M 500% 1900% GJL36007M02 600% 2100%
3 3.9 FAL36007-12M 500% 1800% GJL36007M02 500% 2000%
1 4.1 FAL36007-12M 400% 1700% GJL36007M02 500% 1900%
3 4.8 FAL36007-12M 400% 1500% GJL36007M02 400% 1600%
1125.2 FAL36007-12M 300% 1300% GJL36007M02 400% 1500%
11 6 FAL36007-12Mc300% 1200% GJL36007M02 400% 1300%
5 6.1 FAL36007-12Mc300% 1100% GJL36015M03 700% 2700%
2 6.8 FAL36015-13M 700% 2600% GJL36015M03 700% 2400%
5 7.6 FAL36015-13M 700% 2400% GJL36015M03 600% 2200%
2 7.8 FAL36015-13M 600% 2300% GJL36015M03 600% 2100%
7129 FAL36015-13M 600% 2000% GJL36015M03 500% 1800%
3 9.6 FAL36015-13M 500% 1900% GJL36015M03 500% 1700%
37
1210 11 FAL36015-13M 500% 1600% GJL36015M03 400% 1500%
10 14 FAL36030-15M 700% 2500% GJL36030M04 600% 2400%
5 15.2 FAL36030-15M 700% 2300% GJL36030M04 600% 2200%
15 17 FAL36030-15M 600% 2100% GJL36030M04 500% 1900%
5 17.5 FAL36030-15M 600% 2000% GJL36030M04 500% 1900%
15 21 FAL36030-15M 500% 1700% GJL36030M04 400% 1600%
71220 22 FAL36050-16M 700% 2600% GJL36030M04 400% 1500%
71 25.3 FAL36050-16M 600% 2300% GJL36030M04 400% 1300%
20 25 27 FAL36050-16M 600% 2100% GJL36050M05 600% 2000%
10 28 FAL36050-16M 500% 2100% GJL36050M05 500% 2000%
30 32 FAL36050-16M 500% 1800% GJL36050M05 500% 1700%
10 32.2 FAL36050-16M 500% 1800% GJL36050M05 500% 1700%
25 34 FAL36050-16M 400% 1700% GJL36050M05 400% 1600%
30 40 FAL36050-16M 400% 1500% GJL36050M05 400% 1400%
40 41 FAL36100-18M 700% 2700% GJL36050M05 400% 1300%
15 42 FAL36100-18M 700% 2600% GJL36075M06 400% 1300%
15 48.3 FAL36100-18M 600% 2300% GJL36075M06 500% 1700%
40 50 52 FAL36100-18M 600% 2100% GJL36075M06 400% 1600%
20 54 FAL36100-18M 600% 2000% GJL36075M06 400% 1500%
20 60 62 FAL36100-18M 500% 1800% GJL36075M06 400% 1300%
50 65 FAL36100-18M 500% 1700% GJL36075M06 300% 1300%
25 68 FAL36100-18M 400% 1600%
60 75 77 FAL36150-24M 600% 1400%
25 78.2 FAL36150-24M 600% 1400%
30 80 FAL36150-24M 600% 1400%
30 92 KAL36250-25M 700% 1400%
75 96 KAL36250-25M 700% 1300%
100 99 KAL36250-25M 600% 1300%
40 104 KAL36250-26M 700% 1400%
40 120 KAL36250-29M 700% 1500%
100 124 KAL36250-29M 700% 1400%
125 125 KAL36250-29M 700% 1400%
50 130 KAL36250-29M 700% 1300%
150 144 KAL36250-30M 700% 1400%
50 150 KAL36250-30M 700% 1300%
60 154 KAL36250-31M 700% 1500%
125 156 KAL36250-31M 700% 1400%
60 177.1 KAL36250-32M 700% 1400%
150 180 KAL36250-32M 700% 1400%
75 200 192 KAL36250-32M 700% 1300%
75 221 LAL36400-33M 700% 1400%
200 240 LAL36400-35M 700% 1500%
250 242 LAL36400-35M 700% 1400%
100 248 LAL36400-35M 700% 1400%
100 285 LAL36400-36M 700% 1400%
300 289 LAL36400-36M 700% 1400%
250 302 LAL36400-36M 700% 1300%
125 312 LAL36400-36M 600% 1300%
350 336 MAL36600-40M 700% 1500%
125 359 MAL36600-40M 700% 1400%
150 360 MAL36600-40M 700% 1400%
300 361 MAL36600-40M 700% 1400%
400 382 MAL36600-40M 700% 1300%
150 350 414 MAL36600-42M 700% 1400%
500 472 MAL36600-44M 700% 1500%
400 477 MAL36600-44M 700% 1500%
200 480 MAL36600-44M 700% 1500%
200 552 MAL36800-45M 700% 1400%
500 590 MAL36800-45M 700% 1400%
250 602 MAL36800-45M 700% 1300%
Adjustable Instantaneous-trip Circuit Breakers for Single Motor Circuit Protection
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-27
DE2 DE2A Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
MAG-GARD® — Motor Circuit Protector
Class 580, 585, 680, 685
qUL magnetic trip setting tolerances are -20%/+30% from the nominal values shown.
tNot UL Recognized.
bNo GJL I-LINE available.
kPOWERPACT® MAG-GARD motor circuit protectors are listed on Page 6-17.
Ampere
Rating Adjustableq
Trip Range Amperes Suffix 3-pole only
Catalog Number Price
LAL
400
500-1000
750-1600
1000-2000
1125-2250
1250-2500
1500-3000
1750-3500
2000-4000
LAL3640022M
LAL3640028M
LAL3640030M
LAL3640031M
LAL3640032M
LAL3640033M
LAL3640035M
LAL3640036M
$ 2932.
2932.
2932.
2932.
2932.
2932.
2932.
2932.
MAL a 600
800
1000 625-1250
750-1500
1000-2000
1500-3000
2000-4000
2500-5000
3000-6000
3500-7000
4000-8000
4500-9000
5000-10000
25M
26M
30M
33M
36M
40M
42M
44M
45M
46M
47M
MAL36600
MAL36800
MAL361000
Add
Suffix 4800.
6303.
8067.
NAL 1200 4000-8000
4500-9000
5000-10000
45M
46M
47M
NAL36120045M
NAL36120046M
NAL36120047M
12094.
12094.
12094.
I-LINE, MAG-GARD and POWERPACT are Registered Trademarks of Square D Company or related companies.
aEach Ampere rating can be ordered with any designated trip range for the frame by adding
the proper suffix to the catalog numbers.
p250 Vdc ratings are available except on NA. Contact your nearest Square D/Schneider Electric
sales office for trip range. No UL component recognition.
Magnetic Onlyk 3-1200 Amperes 600 Vac, 50/60 Hzp
Ampere
Rating Adjustableq
Trip Range Amperes 3-pole only
Catalog Number Price
FAL 3
7
15
30
30
50
50
100
100
150
8-28
18-70
50-180
50-180
100-350
75-260
150-580
150-580
300-1100
450-1100
FAL3600311M
FAL3600712M
FAL3601513M
FAL3603013M
FAL3603015M
FAL3605014M
FAL3605016M
FAL3610016M
FAL3610018M
FAL3615024M
$ 575.
575.
575.
575.
575.
730.
730.
872.
872.
1199.
GJL 3
7
15
30
50
75
9-33
21-77
45-165
90-330
150-550
225-825
GJL36003M01
GJL36007M02
GJL35015M03
GJL36030M04
GJL36050M05
GJL36075M06
691.
691.
691.
691.
876.
1043.
KAL 150 750-1500 KAL3615026M 863.
250
400-800
500-1000
625-1250
750-1500
875-1750
1000-2000
1125-2250
1250-2500
1500-3000
KAL3625021M
KAL3625022M
KAL3625025M
KAL3625026M
KAL3625029M
KAL3625030M
KAL3625031M
KAL3625032M
KAL3625033Mt
1650.
1650.
1650.
1650.
1650.
1650.
1650.
1650.
1650.
Instantaneous trip magnetic only circuit breakers have a single
adjustment which simultaneously sets the magnetic trip level of each
individual pole. MAG-GARD circuit breakers comply with NEC
requirements for providing motor circuit protection when installed as part
of a UL Listed combination controller having motor overload protection.
Interrupting ratings are established for these UL Recognized
Components only when they are used in combination with motor
starters with properly sized overload relays and contactors.
All MAG-GARD circuit breakers will accept the same lugs and
accessories as equivalent thermal-magnetic circuit breakers.
MAG-GARD circuit breakers are available with I-LINE constructionb.
H construction MAG-GARD circuit breakers (FHL, KHL, LHL, etc.) are
also available.
AUTOMATIC molded case switches
open instantaneously at a factory preset
magnetic trip point, calibrated to protect
only the molded case switch itself, when
it is subjected to high fault currents. The
trip point is nonadjustable and provides
no overload or low level fault protection.
STANDARD molded case switches
provide no overcurrent protection or
short-circuit protection. They must not be
used on systems that have an available
fault current greater than the values listed
in the table to the right.
Molded case switches open when the
handle is switched to the OFF position or
in response to an auxiliary tripping device
such as a shunt trip.
All standard and automatic switches will
accept the same lugs and accessories as
equivalent thermal-magnetic circuit
breakers, with the exception of the QOU
and Q2 models.
Standard and automatic molded case
switches are UL Listed per UL 1087 and
are CSA Certified.
Q2
Switch KAL MAG-GARD
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 6-37–6-39
Optional Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 6-40, 6-41
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 6-45, 6-46
Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 6-47–6-50
Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 6-23
cThe Withstand Rating is the fault current, at rated voltage, that the molded case switch will withstand without damage when protected by a
circuit breaker with an equal continuous current rating.
uUL magnetic trip setting tolerances are -20% and +30% from the nominal values shown.
tFHL and KHL automatic switches will not accept cylinder lock attachments.
hPOWERPACT® automatic switches are listed on Page 6-17.
Am-
pere
Rating
2-pole 3-pole Withstand Ratingc
Trip Point –
Amperes
(Automatic
Switch) Lug Kit
Installed
Catalog
No. Price Catalog
No. Price 240
Vac 480
Vac 600
Vac 250
Vdc ACuDCu
Standard Molded Case Switches
240 Vac Standard
60
60
100
100
125
QO200
QOU200
QO2000
QOU2000
QOU20001
$ 44.70
55.00
127.00
156.00
287.00
QO300
QOU300
QO3000
QOU3000
QOU30001
$157.00
181.00
232.00
264.00
454.00
10k
10k
10k
10k
10k
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Automatic Molded Case Switches
240 Vac Automatic
225 Q2L2000M $ 279.00 Q2L3000M $ 757.00 10k 4500 N/A N/A
600 Vac Automatic
100
150
250
400
600
800
1000
1200
2000
2500
FHL26000Mt
KHL26000Mt
LHL26000M
MHL260006M
MHL260008M
MHL26000M
NCL2600012M
PHF260000M
PCF260000M
$ 494.00
1160.00
2283.00
3390.00
3804.00
4742.00
6912.00
10055.00
15990.00
FHL36000Mt
FHL3600015Mt
KHL36000Mt
LHL36000M
MHL360006M
MHL360008M
MHL36000M
NCL3600012M
PHF360000M
PCF360000M
$ 635.00
952.00
1451.00
2749.00
4180.00
4594.00
5896.00
7981.00
12418.00
19765.00
65k
65k
65k
65k
65k
65k
65k
125k
125k
125k
25k
25k
35k
35k
65k
65k
65k
100k
100k
100k
18k
18k
25k
25k
25k
25k
25k
65k
65k
65k
10k
10k
10k
10k
10k
10k
1500
2500
4500
8000
9000
9000
9000
16000
16000
16000
1725
5175
9600
9900
9900
9900
N/A
N/A
N/A
AL100FA
AL150FA
AL250KA
AL400LA
AL900MA
AL900MA
AL900MA
AL1200NE6
N/A
N/A
Molded Case Switches and Automatic Molded Case Switchesh
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-28 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Single Motor Branch Circuits
Application Data
Class 601
cOrdinary service for normal starting duty only
with acceleration time of 10 seconds or less.
qHeavy service is jogging or plugging duty or
cycling load with over 25 starts per hour or
over 5 starts per minute. Energy efficient
motors are polyphase motors defined in
NEMA Standard MG1 and exhibit high
starting current.
aNEC Section 430-22 for Single Motor,
Smaller conductors may be permitted for
light duty-cycle service per 430-22 (b)
Exception No. 1. DC motors operating from a
rectified single-phase power supply will
require larger conductors per 430-22 (a)
Exception No. 2. For motor-generator arc
welders, see 630-11.
jMotor full load currents thru 200 HP are
taken from Tables 430-147, 148 and 150 of
the NEC. Above 200 HP from UL 98. Select
wire size, circuit breakers, or fuses on basis
of horsepower rather than nameplate full
load current per NEC Article 430-6. Do not
use these values to select overload relay
thermal units. See Digest Pages 16-16 thru
16-36 for selection of thermal units when
actual full load current is not known. The
voltages listed are rated motor voltages.
Corresponding nominal system voltages are
110 to 120, 200 to 208, 220 to 240, 440 to
480 and 550 to 600 volts.
uSize of switch only is shown in tables above.
Fuses should be selected not to exceed
maximum percent of full-load current as
given in NEC Table 430-152. Above 50
horsepower dc switches are not horsepower
rated by UL as Motor Circuit Switches, but as
General Use Switches only and are not
necessarily capable of interrupting the
maximum operating overload current of a
motor. See NEC Article 100 for definition of
General Use Switch. When protecting a
3-phase, Design E energy efficient motor, the
switch is required by NEC 430-109 to have a
horsepower rating of not less than 1.4 times
that of a motor rated 3-100 hp, or not less
than 1.3 times that of a motor rated over 100
hp. Switches shown in this table do not
necessarily comply with that requirement.
hThermal-magnetic breaker continuous
current ratings recommended are
approximate for average conditions and are
based on trip characteristics of Square D
circuit breakers and NEC Table 430-152.
Under some conditions, the next size larger
switch or breaker rating may be necessary to
accommodate the motor starting current and
is permitted by NEC 430-52(c)(1) Exception
2. High starting currents are anticipated with
Design E and other energy efficient motors.
For explanation of Code letter markings, see
NEC 430-7(b). For Busway Plug-in units, see
Page 9-7.
tThermal-magnetic breaker continuous
current ratings recommended are
approximate for average conditions and
based on trip characteristics of Square D
circuit breakers and NEC Tables 430-7(b)
and 430-152.
I-LINE is a Registered Trademark of
Square D Company or related companies.
NEC is a Registered Trademark of NFPA.
Horsepower Ratings
j
Full
Load
Amps
I-LINE Thermal-Magnetic h
Inverse Time Circuit Breaker u
QMB
and
Heavy
Duty
Switch
with
Time
Delay
Fuses
a
Minimum Size
Metallic Conduit 75˚C,
Copper Wire Field In-
stalled Sized for 125%
FLA
Squirrel-Cage and
Wound-Rotor Motors with
Norm. Torque Characteristics
Operating at Usual Speeds
One Phase
60Hz ac
Average Di-
rect Current
Motors Oper-
ating at Base
Speed
For Motor Code
Letter B to E For Motor
Code Let-
ter
F to V
t
Three Phase 60Hz ac
AWG
kcmil
Conduit 3 W
200p
Volts 230
Volts 460
Volts 575
Volts 115
Volts 200p
Volts 230
Volts 120 V
DC 240 V
DC
c
Ordinary
Service
q
Heavy Service
and Energy Ef-
ficient
THHN
THWN
XHHW THW
346.9 15FA 15FA 20FA
30A
#14 12" N/A
137.2 15FA 15FA 20FA
5347.6 15FA 20FA 20FA
2 7.8 15FA 20FA 20FA
347.9 15FA 20FA 20FA
1 8.0 15FA 20FA 20FA
2 8.5 15FA 20FA 20FA
7129.0 15FA 20FA 25FA
1 9.2 15FA 20FA 25FA
1 9.5 15FA 20FA 25FA
3 9.6 15FA 20FA 25FA
12 9.8 15FA 20FA 25FA
11210.0 20FA 20FA 25FA
37
1210 11.0 20FA 25FA 30FA
11211.5 20FA 25FA 30FA
2 12.0 20FA 20FA 30FA
3 12.2 25FA 25FA 35FA
11213.2 25FA 25FA 35FA
342 13.8 25FA 30FA 35FA
10 14.0 25FA 30FA 35FA
5 15.2 30FA 35FA 40FA
1 16.0 30FA 35FA 40FA
15 3 2 17.0 30FA 35FA 45FA
#12 12" N/A
5 17.5 35FA 35FA 45FA
3 19.6 35FA 40FA 50FA
1125 20.0 40FA 40FA 50FA
15 21.0 40FA 45FA 60FA
#10 12" N/A
71222.0 40FA 45FA 60FA
2 24.0 45FA 50FA 60FA
60A
3 25.0 50FA 50FA 70FA
71225.3 50FA 60FA 70FA
20 25 27.0 50FA 60FA 70FA
10 5 28.0 50FA 60FA 70FA
71229.0 60FA 60FA 80FA
#8 12"k34"
30 32.0 60FA 70FA 80FA
10 32.2 60FA 70FA 90FA
25 3 34.0 60FA 70FA 90FA
10 38.0 80FA 80FA 100KA
30 7125 40.0 80FA 80FA 100KA
41.0 80FA 90FA 110KA
#6 34"1"
15 42.0 80FA 90FA 110KA
71246.0 90FA 110KA 125KA
15 48.3 90FA 110KA 125KA
10 50.0 90FA 110KA 125KA
40 50 52.0 90FA 110KA 150KA
100A
20 54.0 90FA 110KA 150KA
#4 1" 1"
15 55.0 90FA 110KA 150KA
5 56.0 90FA 125KA 150KA
10 57.5 90FA 125KA 150KA
71258.0 90FA 125KA 150KA
60 62.0 100FA 125KA 175KA
20 62.1 100FA 125KA 175KA
50 65.0 100FA 150FA 175KA
25 68.0 100FA 150KA 175KA
20 72.0 110KA 150KA 200KA
#3 1" 114"
10 76.0 125KA 175KA 200KA
60 75 77.0 110KA 175KA 200LA
25 78.2 110KA 175KA 200LA
30 71280.0 110KA 175KA 200LA
25 89.0 125KA 175KA 225LA
200A
#2 1" 114"
30 92.0 125KA 200LA 250LA
75 96.0 125KA 200LA 250LA
#1 114"1
12"
100 99.0 150KA 200LA 250LA
10 100.0 150KA 200LA 250LA
40 104.0 150KA 225LA 300LA
30 106.0 175KA 225LA 300LA 1/0 114"1
12"
40 120.0 175KA 250LA 300LA
100 124.0 200KA 250LA 350LA
2/0" 112"1
12"
125 125.0 200KA 250LA 350LA
50 130.0 200KA 300LA 350LA
40 140.0 200LA 300LA 350LA
150 144.0 200LA 300LA 400MA
3/0 112"2"
50 150.0 200LA 300LA 400MA
60 154.0 225LA 350LA 400MA
125 156.0 225LA 350LA 400MA
50 173.0 250LA 350LA 400MA
400A
4/0 2" 2"
60 177.0 250LA 400MA 500MA
150 180.0 250LA 400MA 500MA
75 200 192.0 250LA 400MA 500MA 250 2" 2"
75 221.0 300LA 450MA 600MA 300 2 212"
200 240.0 350LA 500MA 600MA 350 212"2
12"
250 242.0 350LA 500MA 700MA
100 248.0 350LA 500MA 700MA
100 285.0 400LA 600MA 800MA 500 3" 3"
300 289.0 400LA 600MA 800MA
250 302.0 400LA 700MA 800MA
125 312.0 450MA 700MA 800MA 2 - 3/0 2 - 1122 - 2"
350 336.0 500MA 700MA 900MA
2 - 4/0 2 - 2" 2 - 2"
125 359.0 600MA 800MA 900MA
600A
150 360.0 600MA 800MA 1000NA
300 361.0 600MA 800MA 1000NA
400 382.0 600MA 800MA 1000NA 2 - 300 2 - 2" 2 -
212"
150 350 414.0 600MA 900MA 1200NA
500 472.0 800MA 1000NA 1200NA 2 - 350 2 - 212"2 -
212"
400 477.0 800MA 1000NA 1200NA
200 480.0 800MA 1000NA 1200NA
200 552.0 800MA 1200NA 1600PA . . .
. . .
. . . 3 - 300 3 - 2" 3 -
212"
500 590.0 900MA 1200NA 1600PA
250 602.0 900MA 1200NA 1600PA
SELECTION TABLES FOR
CONDUCTORS, SAFETY
SWITCHES AND THERMAL-
MAGNETIC CIRCUIT BREAKERS
Based on 1999 NEC Tables
430-147, 430-148 & 430-150
k#8 XHHW requires 34" conduit for 3W. p200 V. motors are commonly used on 208V. services.
Contact your nearest Square D/Schneider
Electric sales office for circuit breaker
selection on constant horsepower multi-
speed motors.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-29
DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Availability to
be Announced
Ground-fault Protection Equipment
Class 931, 940, 960
BOLT-LOC, GROUND-CENSOR
and MICROLOGIC are Registered
Trademarks of Square D Company
or related companies.
GC-200 Ground-fault System
GC-200 Ground Fault Relays work in conjunction with new Square D bolted pressure switches, or circuit breaker shunt
trip coils installed in service entrance switchboards. GC-200 relays replace existing Square D GC-100 relays.
GC-200 Relays Features
kAdjustable Pickup and Time Delay settings
kI2t – Inverse Time Characteristics
kZSI – Zone Selective Interlocking
kZSI Push-to-Test with Signal Indication
kClosing Contacts (2 N./O., 1 N./C.)
kAuxiliary Input Terminals
kExternal Battery Backup Connection
kOptional GCDSP Display Module
GCDSP Display Features
kLCD Back Lit Display
kSurface Mounted
kLocal Display of System Parameters
k"Fine tuning" Adjustment of Ground Fault Relay Pickup
Settings
kRemote Testing of Ground Fault Relay
kRemote Resetting of Ground Fault Relay
kMultiple Length Display Cables ( Optional )
GFR Features – Adjustable Pickup and Time Delay Settings – The following tables illustrate the ground fault pickup and
time delay settings available for each relay:
aNote: I2t inverse time on and off settings are available for GC-200D and GC-200E.
tNote: GC4 4' cable shipped standard with GCDSP display units.
Catalog Number Adjustable Pickup Settings
GC-200D 30 A 90 A 90 A 120 A 150 A 180 A 210 A 240 A 270 A 300 A
GC-200E 120 A 240 A 360 A 480 A 600 A 720 A 840 A 960 A 1080 A 1200 A
Catalog Number Adjustable Time Delay Settings
GC-200Da0.1 0.2 0.3 0.5 0.5 0.3 0.2 0.1 0 . . .
GC-200Ea0.1 0.2 0.3 0.5 0.5 0.3 0.2 0.1 0 . . .
Catalog Number Description Price
GC-200D 30 A–300 A Relay $1879.
GC-200E 120 A–1200 A Relay 1879.
GCDSP GC-200 Display 602.
GC4t4’ GC-200 to GCDSP Cable 61.
GC12 12’ GC-200 to GCDSP Cable 100.
GC30 30’ GC-200 to GCDSP Cable 191.
Catalog Number Description Window Size (in) Window Size (mm) Price
GT 912
Ground Fault Sensor
512 x 812
512 x 1412
512 x 2612
812 x 1412
812 x 2012
812 x 2612
1112 x 2612
912 x 24
912 x 27
(140 x 216)
(140 x 368)
(140 x 673)
(216 x 368)
(216 x 521)
(216 x 673)
(292 x 673)
(241 x 610)
(241 x 686)
$1123.
GT 918 1307.
GT 930 1756.
GT 1218 1679.
GT 1224 1842.
GT 1230 2061.
GT 1530 2366.
GT 1327 1806.
GT 1330 2044.
GROUND-CENSOR® Type GC 100 – 600 Vac
Type GC GROUND-CENSOR equipment ground-fault protection systems are ideally
suited for protection of main and feeder circuits on solidly grounded electrical distribution
systems. The GC system requires the following components: GC relay, GT sensor, circuit
interrupter with 120 Vac shunt trip, and monitor components.c
A nameplate is supplied with each GC100 giving operation instructions for “Test With and Without Tripping” arrangement
.
cOrder components individually for monitor.
qWhen using zone-selective interlocking with MICROLOGIC circuit breakers, a restraint interface module will be
required. See Supplemental Digest.
Description Usable Window Size Catalog Number Price
Inches mm
Type GC Relay . . . . . . GC-100 $1879.
Ground-fault Sensors
512 x 812
512 x 1412
512 x 2612
812 x 1412
812 x 2012
812 x 2612
1112 x 2612
912 x 24
912 x 27
(140 x 216)
(140 x 368)
(140 x 673)
(216 x 368)
(216 x 521)
(216 x 673)
(292 x 673)
(241 x 610)
(241 x 686)
GT 912
GT 918
GT 930
GT 1218
GT 1224
GT 1230
GT 1530
GT 1327
GT 1330
1123.
1307.
1756.
1679.
1842.
2061.
2366.
1806.
2044.
cMonitor Components
Type GC
Test With and
Without Tripping
Test Button
Reset Button
Test Relay
Relay Socket
Class 9001 Type K1L38GH2
Class 9001 Type K1L38RH1
Class 8501 Type RS14, 120 Vac
Class 8501 Type NR45
Type GC Features:
k120 Vac 50/60 Hz power required (50 VA min.). Contact
your nearest Square D/Schneider Electric sales office
on additional VA requirement of circuit breaker or
BOLT-LOC®.
kGround-fault current pickup adjustable from 100-1200
Amperes.
kTime delay field adjustable 0.1, 0.2, 0.3, or 0.5
seconds.
kMonitor panel provides visual ground-fault indication
and testing provisions to meet NEC 230-95. (Requires
50 VA control power, 120 Vac). Monitor panel
components must be ordered separately.
k120 Vac shunt trip is required on the circuit breaker or
the BOLT-LOC® switch to interrupt the circuit.
kZone-selective interlocking capability with
MICROLOGIC® circuit breakers and GC systems is
standard for multiple level protection.q
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-30 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
DE2 Discount
Schedule
Ground-fault Protection Equipment
Class 931, 940, 960
GROUND-CENSOR® Type GA – 600 Vac
The Type GA GROUND-CENSOR equipment ground-fault protection system is recommended for
protection of motor branch circuits. The type GA system is not recommended for service entrance
applications, see GC system on previous page. The GA system requires the following components:
GA relay, GA sensor, and circuit interrupter with 120 Vac shunt trip. GA test panel is optional, however
sensor selected must be compatible with test panel when one is useda.
Type GA System Features:
Ground-fault current pickup adjustable from 4-1200 Amperes, dependent on the sensor used and
the connections.
Time delay field adjustable from instantaneous to 36 cycles.
Test panel available to meet NEC 230-95. Test with or without tripping. Requires 120 Vac 50/60 Hz
power (50 VA min.).
120 Vac shunt trip is required on the circuit breaker to interrupt the circuit.
Relay contacts are rated for 10 Amperes continuous @ 250 Vac UL Listed..
aDoes not have connections for test panel.
pRequires 2 inch clearance from current carrying wires on all sides.
MICROLOGIC® Add-on Ground-fault Modules (GFM)
The MICROLOGIC ground-fault Module (GFM) is a UL Listed circuit breaker accessory. It is a combi-
nation ground-fault relay and ground-fault sensing device.
MICROLOGIC Add-on Ground-fault Module Features:
Used in combination with the FA, KA, FC, KC, FI, and KI type circuit breakers with a ground-fault
shunt trip factory installed.
Molded case circuit breakers used with the GFM require ground-fault shunt trip (add the suffix “G”
to the circuit breaker).
Adjustable ground-fault pickup levels.
Adjustable ground-fault time delays.
Integral ground fault push-to-test feature and ground-fault indicator.
All GFMs supplied for I-LINE mounting, easily convertible to unit mount by removing the I-LINE
brackets.
Neutral current transformer is supplied for 3-phase 4-wire applications. Refer to instructions for
proper installation.
Zone-selective interlocking capability is standard with upstream MICROLOGIC trip system circuit
breakers. The GFM can also be zone interlocked with the GC ground-fault system by using a
restraint interface module. See Supplementary Catalog.
120 Vac control power is required for integral test feature. Meets NEC 230-95(c).
tUse NEMA Type 1 or Type 3R enclosures only. See Page 6-48 for dimensions.
For NEMA Type 4, 4X, 5 Stainless Steel or Type R enclosures, see Page 6-49.
Description Ground-fault
Trip Range Catalog
Number Price
Instantaneous relay
Time delay relay
(for motor starter applications)
Dependent on sensor
and connections GA 12
GAT 12 $629.
907.
Sensor
Type GAp Window Size
334" Diameter
334" Diameter
212" Diameter
778" x 1114"
778" x 1534"
778" x 2458"
4-12, 12-36 Amperes
4-12 Amperes
4-12 Amperes
25-75, 50-150, 150-450, 400-1200 Amperes
50-150, 150-450, 400-1200 Amperes
150-400, 400-1200 Amperes
GA 375T
GA 375a
GA 250a
GA 811
GA 816
GA 825
426.
388.
359.
769.
873.
1057.
Test Panel Same As Sensor GA 12TPM 1009.
Module/Enclosure Selection Chart
Companion
Circuit Breaker
Prefix
Catalog
Number
Enclosure Space Required Ground-fault
Pickup Adjustment
Range Amperes GFM Price
I-LINE
Switchboard Individual
Enclosuret
FAL, FHL, FCL,
FA, FH, FC GFM100FA LA KA 20-100 $2698.
FI GFM100FI LA 20-100 2698.
KAL, KHL, KI,
KA, KH, KC GFM250 LA LA 40-200 2698.
FIL GFM100FI Factory installed only.
See page 6-49
20-100 2698.
KCL, KIL GFM250 40-200 2698.
GROUND-CENSOR and MICROLOGIC are Registered Trademarks of Square D Company or related companies.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-31
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
MICROLOGIC® Trip Systems and
Insulated Case Circuit Breakers
Class 661, 666, 671, 677, 678
MICROLOGIC® Series B Trip System Standard-function Features:
k80% Rated
kTrue RMS Sensing
kInterchangeable Rating Plugs
kLSI, LS(I)G, Trip Configurations
kShort-time Delay = I2t IN and Ground-fault Delay = I2t OUT
kIntegral Ground-fault Testing
kLED Long-time Pickup Indication
kThermal & Magnetic Backup Protection
kLong-time & Ground-fault Memory
kOptional Local Trip Indicators - Overload, Short-circuit, Ground- fault
kOptional Local Ammeter/Trip Indicator
kUniversal Test Set Available
kOptional I-LINE® Mounting (LX, LXI, MX, NX)
kOptional Neutral Current Transformer for 4-Wire Systems
Full-function Features:
k100% Rated (600 sensor LE/LEL and 2500 sensor PEF circuit breakers are 80% rated)
kTrue RMS Sensing
kInterchangeable Rating Plugs
kPOWERLOGIC® Compatible
kLI, LIG, LS(I), LS(I)G (Instantaneous OFF) Configurations
kShort-time Delay = I2t IN & I2t OUT and Ground-fault Delay = I2t IN & I2t OUT
kShort-time Withstand Rating
kIntegral Ground-fault Testing
kOptional Ground-fault Alarm (No Trip) (Requires CIM3F with POWERLOGIC or see
Bulletin 0602PD9701.)
kLED Long-time Pickup Indication
kZone Selective Interlocking (Short-time & Ground-fault)
kThermal & Magnetic Backup Protection
kLong-time & Ground-fault Memory
kLocal Trip Indicators - Overload, Short-circuit, Ground-fault
kLocal Ammeter/Trip Indicator
kUniversal Test Set Available
kOptional I-LINE® Mounting (LE, ME, NE)
kOptional Neutral Current Transformer for 4-Wire Systems
SE 250 to 4000 A Electronic Trip Insulated Case Circuit Breaker:
kIdeal for switchboard applications (standard for Square D)
kComplies with UL 489
kUL Listed for continuous operation at 100% of the current ratings
k80 to 4000 ampere continuous current ratings
kHigh short time ratings
kDrawout or fixed-mounted circuit breaker
kTwo-step stored energy mechanism (mechanically or electrically operated)
5 cycle closing times
kTrue RMS sensing
kAdjustable LSIG trip functions
kInterchangable rating plugs
kLocal electronic trip indication and local current meter
kField replaceable accessories
kZone Selective Interlocking
kPOWERLOGIC® compatible communications
kComplete system solutions – switchboards (main-tie-main, zone selective interlocking,
and modified differential ground fault schemes)
Please refer to the Supplemental Digest for selection and pricing information.
Circuit Breakers with MICROLOGIC Standard-function Trip
Systems (LX, LXI, MX, NX and PX)
Accessories .................................................................Pages 6-35, 6-37–6-39
Optional Lugs ........................................................................Pages 6-40, 6-41
Dimensions .............................................................................Pages 6-45, 6-46
Enclosures ............................................................................. Pages 6-47–6-50
I-LINE, MASTERPACT, MICROLOGIC and POWERLOGIC are Registered Trademarks of Square D Company or related companies.
SE
Circuit Breakers with MICROLOGIC Full-Function Trip
Systems (LE, ME, NE, PE and SE)
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-32 DE2 Discount
Schedule 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Electronic Trip Circuit Breakers
600 A Frame
Class 661
q600 Ampere sensor is 80% rated
aSubstitute (A) in place of (G) for ground-fault alarm (pick up indication only.) No instantaneous OFF position for LI or LIG circuit breakers.
L Frame – 600 A, MICROLOGIC Trip System
3-Pole, 600 V
Sensor
Size Ampere
Rating
Trip
Func-
tion
Standard Function Standard Function
Current Limiting 100% Ratedq
Full FunctionaInstalled
Rating
Plug
Terminal
Wire Range
Catalog
Number List Price Catalog
Number List Price Catalog
Number List Price
250
100
LI . . . . . . . . . . . . LEL36100LI $ 4884.
ARP040
AL600LI35
2-#1 AWG-
350 kcmil
LSI LXL36100 $3566. LXIL36100 $ 7150. LEL36100LS 8276.
LIG . . . . . . . . . . . . LEL36100LIG 6202.
LSIG LXL36100G 4883. LXIL36100G 8467. LEL36100LSG 9594.
125
LI . . . . . . . . . . . . LEL36125LI 4884.
ARP050
LSI LXL36125 3566. LXIL36125 7150. LEL36125LS 8276.
LIG . . . . . . . . . . . . LEL36125LIG 6202.
LSIG LXL36125G 4883. LXIL36125G 8467. LEL36125LSG 9594.
150
LI . . . . . . . . . . . . LEL36150LI 4884.
ARP060
LSI LXL36150 3566. LXIL36150 7150. LEL36150LS 8276.
LIG . . . . . . . . . . . . LEL36150LIG 6202.
LSIG LXL36150G 4883. LXIL36150G 8467. LEL36150LSG 9594.
175
LI . . . . . . . . . . . . LEL36175LI 4884.
ARP070
LSI LXL36175 3566. LXIL36175 7150. LEL36175LS 8276.
LIG . . . . . . . . . . . . LEL36175LIG 6202.
LSIG LXL36175G 4883. LXIL36175G 8467. LEL36175LSG 9594.
200
LI . . . . . . . . . . . . LEL36200LI 4884.
ARP080
LSI LXL36200 3566. LXIL36200 7150. LEL36200LS 8276.
LIG . . . . . . . . . . . . LEL36200LIG 6202.
LSIG LXL36200G 4883. LXIL36200G 8467. LEL36200LSG 9594.
225
LI . . . . . . . . . . . . LEL36225LI 4884.
ARP090
LSI LXL36225 3566. LXIL36225 7150. LEL36225LS 8276.
LIG . . . . . . . . . . . . LEL36225LIG 6202.
LSIG LXL36225G 4883. LXIL36225G 8467. LEL36225LSG 9594.
250
LI . . . . . . . . . . . . LEL36250LI 4884.
ARP100
LSI LXL36250 3566. LXIL36250 7150. LEL36250LS 8276.
LIG . . . . . . . . . . . . LEL36250LIG 6202.
LSIG LXL36250G 4883. LXIL36250G 8467. LEL36250LSG 9594.
400
300
LI . . . . . . . . . . . . LEL36300LI 6788.
ARP075
AL600LI5
2-#4/0 AWG-
500 kcmil
LSI LXL36300 5471. LXIL36300 10412. LEL36300LS 10180.
LIG . . . . . . . . . . . . LEL36300LIG 8106.
LSIG LXL36300G 6788. LXIL36300G 11730. LEL36300LSG 11498.
350
LI . . . . . . . . . . . . LEL36350LI 6788.
ARP088
LSI LXL36350 5471. LXIL36350 10412. LEL36350LS 10180.
LIG . . . . . . . . . . . . LEL36350LIG 8106.
LSIG LXL36350G 6788. LXIL36350G 11730. LEL36350LSG 11498.
400
LI . . . . . . . . . . . . LEL36400LI 6788.
ARP100
LSI LXL36400 5471. LXIL36400 10412. LEL36400LS 10180.
LIG . . . . . . . . . . . . LEL36400LIG 8106.
LSIG LXL36400G 6788. LXIL36400G 11730. LEL36400LSG 11498.
600q
450
LI . . . . . . . . . . . . LEL36450LI 9326.
ARP075
LSI LXL36450 8007. LXIL36450 14762. LEL36450LS 12718.
LIG . . . . . . . . . . . . LEL36450LIG 10644.
LSIG LXL36450G 9325. LXIL36450G 16079. LEL36450LSG 14037.
500
LI . . . . . . . . . . . . LEL36500LI 9326.
ARP083
LSI LXL36500 8007. LXIL36500 14762. LEL36500LS 12718.
LIG . . . . . . . . . . . . LEL36500LIG 10644.
LSIG LXL36500G 9325. LXIL36500G 16079. LEL36500LSG 14037.
600
LI . . . . . . . . . . . . LEL36600LI 9326.
ARP100
LSI LXL36600 8007. LXIL36600 14762. LEL36600LS 12718.
LIG . . . . . . . . . . . . LEL36600LIG 10644.
LSIG LXL36600G 9325. LXIL36600G 16079. LEL36600LSG 14037.
Interrupting Ratings (kA)
LXL LEL LXIL
240 V 100 100 200
480 V 65 65 200
600 V 35 35 100
Accessories .................................................................Pages 6-35, 6-37–6-39
Optional Lugs ....................................................................... Pages 6-40, 6-41
Dimensions............................................................................... Page 6-45, 6-46
Enclosures.............................................................................. Pages 6-47–6-50
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-33
DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Electronic Trip Circuit Breakers
800, 1200 A Frame
Class 666, 671
aSubstitute (A) in place of (G) for ground-fault alarm (pick up indication only.) No instantaneous OFF position for LI or LIG circuit breakers.
M Frame800 A, MICROLOGIC Trip System
3-Pole, 600 V
Sensor
Size Ampere
Rating Trip
Function
Standard Function 100% Rated, Full FunctionaInstalled
Rating
Plug
Terminal Wire
Range
Catalog Number List Price Catalog Number List Price
800
450
LI . . . . . . MEL36450LI $11381.
ARP056
AL900MA
3-#3/0-500 kcmil
LSI MXL36450 $ 8711. MEL36450LS 14773.
LIG . . . . . . MEL36450LIG 14773.
LSIG MXL36450G 10029. MEL36450LSG 18165.
500
LI . . . . . . MEL36500LI 11381.
ARP063
LSI MXL36500 8711. MEL36500LS 14773.
LIG . . . . . . MEL36500LIG 14773.
LSIG MXL36500G 10029. MEL36500LSG 18165.
600
LI . . . . . . MEL36600LI 11381.
ARP075
LSI MXL36600 8711. MEL36600LS 14773.
LIG . . . . . . MEL36600LIG 14773.
LSIG MXL36600G 10029. MEL36600LSG 18165.
700
LI . . . . . . MEL36700LI 11381.
ARP088
LSI MXL36700 8711. MEL36700LS 14773.
LIG . . . . . . MEL36700LIG 14773.
LSIG MXL36700G 10029. MEL36700LSG 18165.
800
LI . . . . . . MEL36800LI 11381.
ARP100
LSI MXL36800 8711. MEL36800LS 14773.
LIG . . . . . . MEL36800LIG 14773.
LSIG MXL36800G 10029. MEL36800LSG 18165.
N Frame1200 A, MICROLOGIC Trip System
3-Pole, 600 V
Sensor
Size Ampere
Rating Trip
Function
Standard Function 100% Rated, Full FunctionaInstalled
Rating
Plug
Terminal Wire
Range
Catalog Number List Price Catalog Number List Price
1200
600
LI . . . . . . NEL36600LI $20553.
ARP050
AL1200NE6
4-#3/0-600 kcmil
LSI NXL36600 $13252. NEL36600LS 23945.
LIG . . . . . . NEL36600LIG 23945.
LSIG NXL36600G 14570. NEL36600LSG 27337.
700
LI . . . . . . NEL36700LI 20553.
ARP058
LSI NXL36700 13252. NEL36700LS 23945.
LIG . . . . . . NEL36700LIG 23945.
LSIG NXL36700G 14570. NEL36700LSG 27337.
800
LI . . . . . . NEL36800LI 20553.
ARP067
LSI NXL36800 13252. NEL36800LS 23945.
LIG . . . . . . NEL36800LIG 23945.
LSIG NXL36800G 14570. NEL36800LSG 27337.
900
LI . . . . . . NEL36900LI 20553.
ARP075
LSI NXL36900 13252. NEL36900LS 23945.
LIG . . . . . . NEL36900LIG 23945.
LSIG NXL36900G 14570. NEL36900LSG 27337.
1000
LI . . . . . . NEL361000LI 20553.
ARP083
LSI NXL361000 13915. NEL361000LS 23945.
LIG . . . . . . NEL361000LIG 23945.
LSIG NXL361000G 15233. NEL361000LSG 27337.
1200
LI . . . . . . NEL361200LI 20553.
ARP100
LSI NXL361200 13915. NEL361200LS 23945.
LIG . . . . . . NEL361200LIG 23945.
LSIG NXL361200G 15233. NEL361200LSG 27337.
Accessories ................................................................. Pages 6-35, 6-37–6-39
Optional Lugs ........................................................................Pages 6-40, 6-41
Dimensions ...............................................................................Page 6-45, 6-46
Enclosures ..............................................................................Pages 6-47–6-50
Interrupting Ratings (kA)
MXL MEL NXL NEL
240 V 65 65 125 125
480 V 65 65 100 100
600 V 25 25 65 65
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-34 DE2 Discount
Schedule 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Electronic Trip Circuit Breakers
2500 A Frame
Class 677
PEF-20, PXF-25 or PEF-25 circuit breakers are supplied with terminal pads
for both ends of the circuit breaker. The supplied terminal pads or equivalent
bus structure must be used for bus or cable connections. Terminal pads have
provisions for mounting a maximum of eight lugs per phase. Order lugs sepa-
rately. See Pages 6-40 and 6-41.
q2500 Ampere sensor is 80% rated.
aSubstitute (A) in place of (G) for ground-fault alarm (pick up indication only.) No instantaneous OFF position for LI or
LIG circuit breakers.
P Frame – 2500 A, MICROLOGIC Trip System
3-Pole, 600 V
Sensor
Size Ampere
Rating Trip
Function
Standard Function 100% Ratedq, Full FunctionaInstalled
Rating
Plug
Catalog Number List Price Catalog Number List Price
1200
600
LI . . . . . . PEF36600LI $18516.
ARP050
LSI PXF36600 $11982. PEF36600LS 21908.
LIG . . . . . . PEF36600LIG 21908.
LSIG PXF36600G 13300. PEF36600LSG 25300.
700
LI . . . . . . PEF36700LI 18516.
ARP058
LSI PXF36700 11982. PEF36700LS 21908.
LIG . . . . . . PEF36700LIG 21908.
LSIG PXF36700G 13300. PEF36700LSG 25300.
800
LI . . . . . . PEF36800LI 18516.
ARP067
LSI PXF36800 11982. PEF36800LS 21908.
LIG . . . . . . PEF36800LIG 21908.
LSIG PXF36800G 13300. PEF36800LSG 25300.
900
LI . . . . . . PEF36900LI 18516.
ARP075
LSI PXF36900 11982. PEF36900LS 21908.
LIG . . . . . . PEF36900LIG 21908.
LSIG PXF36900G 13300. PEF36900LSG 25300.
1000
LI . . . . . . PEF361000LI 18516.
ARP083
LSI PXF361000 11982. PEF361000LS 21908.
LIG . . . . . . PEF361000LIG 21908.
LSIG PXF361000G 13300. PEF361000LSG 25300.
1200
LI . . . . . . PEF361200LI 18516.
ARP100
LSI PXF361200 11982. PEF361200LS 21908.
LIG . . . . . . PEF361200LIG 21908.
LSIG PXF361200G 13300. PEF361200LSG 25300.
1600
1400
LI . . . . . . PEF361400LI 19938.
ARP088
LSI PXF361400 13086. PEF361400LS 23330.
LIG . . . . . . PEF361400LIG 23330.
LSIG PXF361400G 14403. PEF361400LSG 26722.
1600
LI . . . . . . PEF361600LI 19938.
ARP100
LSI PXF361600 13086. PEF361600LS 23330.
LIG . . . . . . PEF361600LIG 23330.
LSIG PXF361600G 14403. PEF361600LSG 26722.
2000
1800
LI . . . . . . PEF361800LI 23654.
ARP090
LSI PXF361800 14751. PEF361800LS 27046.
LIG . . . . . . PEF361800LIG 27046.
LSIG PXF361800G 16069. PEF361800LSG 30438.
2000
LI . . . . . . PEF362000LI 23654.
ARP0100
LSI PXF362000 14751. PEF362000LS 27046.
LIG . . . . . . PEF362000LIG 27046.
LSIG PXF362000G 16069. PEF362000LSG 30438.
2500q2500
LI . . . . . . PEF362500LI 36141.
ARP100
LSI PXF362500 24928. PEF362500LS 39533.
LIG . . . . . . PEF362500LIG 39533.
LSIG PXF362500G 26247. PEF362500LSG 42925.
Interrupting Ratings (kA)
PXF PEF
240 V 125 125
480 V 100 100
600 V 65 65
Accessories .................................................................Pages 6-35, 6-37–6-39
Optional Lugs ....................................................................... Pages 6-40, 6-41
Dimensions............................................................................... Page 6-45, 6-46
Enclosures.............................................................................. Pages 6-47–6-50
PXF-12, PEF-12, PXF-16, PEF-16, and PXF-20 circuit breakers can be bus
or cable connected. For cable connections, optional terminal pad kit PALTB or
equivalent bus structure is required. Each PALTB kit contains terminal pads for
one end of the circuit breaker only and has provisions for mounting a
maximum of six lugs per phase. Order lugs separately. See Pages 6-40
and 6-41.
PALTB
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-35
DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
MICROLOGIC® Circuit Breaker Options
Class 661, 666, 671, 677, 678
Combination Local Current Meter
and Trip Indicator
MICROLOGIC and POWERLOGIC are Registered Trademarks of Square D Company.
NEC is a Registered Trademark of National Fire Protection Association.
CIM3F
Communication
Adapter
Electronic Trip Unit with Seals Installed
to Restrict Access
Universal Test Set
Complying with NEC®
The National Electric Code, Section 240-6(b) exception allows conductor Ampere ratings
equal to the selected long-time pick-up setting. Square D offers the seals below to restrict
access to trip unit once settings are selected.
tRequired for MICROLOGIC® to communicate with POWERLOGIC® system.
qSee Supplemental Digest for more information.
Neutral Current Transformers
Catalog No. Price Sensor Where Used
LE25CT2
LE4CT2
LE6CT2
$373.
373.
373.
250
400
600
LXL, LEL, LXIL
LXL, LEL, LXIL
LXL, LEL, LXIL
ME8CT2 373. 800 MXL, MEL
NE12CT2 373. 1200 NXL, NEL
PE12CT2
PE16CT2
PE20CT2
PE25CT2
373.
373.
373.
373.
1200
1600
2000
2500
PXF, PEF
PXF, PEF
PXF, PEF
PXF, PEF
Electronic Trip Indicator and Current Meter Field-installable Kits
Device Catalog No. Included With
Circuit Breaker Optional Price
Local Trip Indicator Kit ALTI . . . . LXL, MXL, NXL, LXIL $ 928.
Local Trip Indicator Kit ALTIP . . . . PXF 928.
Local Current Meter Kit/Trip Indicator ALAM LEL, MEL, NEL, SE LXL, LXIL, MXL, NXL 1451.
Local Current Meter Kit/Trip Indicator ALAMP PEF PXF 1451.
Description Catalog Number Package Quantity Price
Trip Unit Seal TUSEAL 100 $65.
Description Catalog Number Price
Communication Adapter CIM3Ft$295.
Interchangeable Rating Plug Kits for all Circuit Breakers
with MICROLOGIC Trip System
Catalog No. Sensor Multiplier Value Price
ARP040 0.400 $189.
ARP050 0.500 189.
ARP056 0.563 189.
ARP058 0.583 189.
ARP060 0.600 189.
ARP063 0.625 189.
ARP067 0.667 189.
ARP070 0.700 189.
ARP075 0.750 189.
ARP080 0.800 189.
ARP083 0.833 189.
ARP088 0.875 189.
ARP090 0.900 189.
ARP100 1.000 189.
Test Equipment for Circuit Breakers with MICROLOGIC Trip Systems
Description Catalog
Number Price
Universal Test Set (includes test module for Full-function and Standard-function LEL, LXL, LXIL,
MEL, NEL, PEF, SE, MXL, NXL, PXF) UTS3 $8903.
Test Module for Full-function and Standard-function LEL, LXL, LXIL, MEL, NEL, PEF, SE, MXL,
NXL, PXF. (For use with existing CBTU1 or UTS3 test set.) CBTMB 1491.
Replacement ribbon cable and rating plug adapter for CBTMB CBTMBRK 398.
Long-time and ground-fault Memory Reset Module (Series I and II) MTM2 358.
Long-time and ground-fault Memory Reset Module (Series III Electronics) MTM3 242.
Long-time and ground-fault Memory Reset Module (Series B Electronics) MTMB 242.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-36 DE2 Discount
Schedule 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
EH/EHB and GJL Circuit Breakers
Class 590, 652
E Frame – 100 A, Thermal Magnetic (480Y/277 Vac)
qUL Listed as SWD (switching duty) rated.
pFor use only in Series 3 or Series E1 panelboards. Contact your nearest Square D/Schneider Electric sales office for use in earlier series panelboards
Amp
Rating
1-Pole
277 V ac — 14,000 AIR
120 Vac — 65,000 AIR
2-Pole
480Y/277 Vac — 14,000 AIR
120/240 Vac — 65,000 AIR
3-Pole
480Y/277 Vac — 14,000 AIR
240 Vac — 65,000 AIR
Wire Size
(AWG) Wire
Temp.
Plug-on Bolt-on Plug-on Bolt-on Plug-on Bolt-on
Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price Al Cu
EH/EHB
15 EH14015q$85. EHB14015 q$95. EH24015 $214. EHB24015 $243. EH34015 $387. EHB34015 $425. . . . (2)-#14-#10 60/75°C
20 EH14020q85. EHB14020 q95. EH24020 214. EHB24020 243. EH34020 387. EHB34020 425. . . . (2)-#14-#10 60/75°C
25 EH14025 85. EHB14025 95. EH24025 214. EHB24025 243. EH34025 387. EHB34025 425. #12-#8 #14-#8 60/75°C
30 EH14030 85. EHB14030 95. EH24030 214. EHB24030 243. EH34030 387. EHB34030 425. #12-#8 #14-#8 60/75°C
35 EH14035 85. EHB14035 95. EH24035 214. EHB24035 243. EH34035 387. EHB34035 425. #12-#2 #14-#2 75°C
40 EH14040 85. EHB14040 95. EH24040 214. EHB24040 243. EH34040 387. EHB34040 425. #12-#2 #14-#2 75°C
45 EH14045 85. EHB14045 95. EH24045 214. EHB24045 243. EH34045 387. EHB34045 425. #12-#2 #14-#2 75°C
50 EH14050 85. EHB14050 95. EH24050 214. EHB24050 243. EH34050 387. EHB34050 425. #12-#2 #14-#2 75°C
60 EH14060 85. EHB14060 95. EH24060 214. EHB24060 243. EH34060 387. EHB34060 425. #12-#2 #14-#2 75°C
70 . . . . . . . . . . . . . . . . . . . . . . . . . . . EHB24070p480. . . . . . . . . . EHB34070p578. #4-#2/0 #4-#2/0 75°C
80 . . . . . . . . . . . . . . . . . . . . . . . . . . . EHB24080p480. . . . . . . . . . EHB34080p578. #4-#2/0 #4-#2/0 75°C
90 . . . . . . . . . . . . . . . . . . . . . . . . . . . EHB24090p480. . . . . . . . . . EHB34090p578. #4-#2/0 #4-#2/0 75°C
100 . . . . . . . . . . . . . . . . . . . . . . . . . . . EHB24100p480. . . . . . . . . . EHB34100p578. #4-#2/0 #4-#2/0 75°C
EH/EHB HID Circuit Breakers — For Use on High Intensity Discharge Lighting Systems
15 EH14015HIDq94. EHB14015HID q108. EH24015HID 232. EHB24015HID 259. EH34015HID 411. EHB34015HID 449. . . . (2)-#14-#10 60/75°C
20 EH14020HIDq94. EHB14020HID q108. EH24020HID 232. EHB24020HID 259. EH34020HID 411. EHB34020HID 449. . . . (2)-#14-#10 60/75°C
25 EH14025HID 94. EHB14025HID 108. EH24025HID 232. EHB24025HID 259. EH34025HID 411. EHB34025HID 449. #12-#8 #14-#8 60/75°C
30 EH14030HID 94. EHB14030HID 108. EH24030HID 232. EHB24030HID 259. EH34030HID 411. EHB34030HID 449. #12-#8 #14-#8 60/75°C
Requires
1 Space Requires
1 Space Requires
2 Spaces Requires
2 Spaces Requires
3 Spaces Requires
3 Spaces
Electrical and mechanical accessories listed below are for use with GJL instantaneous-trip and thermal-magnetic circuit
breakers. All ac electrical accessories shown below are rated for 50/60 Hz.
qSame accessory – Application depends on installation location. Switch has common and both normally open and normally closed contacts.
Field-installable Electrical Accessories for GJL Circuit Breakers
Accessory Description Rated Voltage Coil
Burden Catalog
No. Price
Shunt Trip
Trips the circuit breaker from a remote location by
means of a trip coil energized from a separate
circuit. All shunt trips will operate at 55% or more of
rated voltage.
AC 120
208
240
277
480
DC 24
48
125
250
50mA
29mA
25mA
22mA
13mA
250mA
125mA
48mA
24mA
GSA
GSB
GSC
GSD
GSH
GSO
GSP
GSR
GSS
$455.
455.
455.
455.
455.
455.
455.
455.
455.
Undervoltage Trip
Trips the circuit breaker electrically when a control
circuit falls below 35 to 70% of nominal voltage.
(Not field adjustable.) Picks up at 35 to 85% of
nominal voltage. UVR must be energized in order to
close the circuit breaker.
AC 120
208
240
277
480
DC 24
48
125
250
50mA
29mA
25mA
22mA
13mA
250mA
125mA
48mA
24mA
GUA
GUB
GUC
GUD
GUH
GUO
GUP
GUR
GUS
455.
455.
455.
455.
455.
455.
455.
455.
455.
Auxiliary Switch Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker
contacts are OPEN or CLOSED. Ratings: 3A-600 Vac, 6A-480 Vac, 0.3A-250 Vdc, 0.8A-125 Vdc AACq189.
Alarm Switch Used with control circuits and is actuated only when the circuit breaker has tripped.
Ratings: 3A-600 Vac, 6A-480 Vac, 0.3A-250 Vdc, 0.8A-125 Vdc AACq189.
Field-installable External Accessories
DIN Rail Adapter Hardware that allows mounting on standard 35 mm DIN rail. GYR 59.00
Terminal Shields Used to prevent accidental contact with live parts. GYT 47.60
Padlock Attachment Prevents access to unauthorized personnel. Locks in OFF position only.
Suitable for padlock with a shaft diameter up to 0.312 in. (8 mm). AHP 12.50
Cover Screw Seal (10) Cover Screw Seals to prevent unauthorized removal of circuit breaker cover. ACS 11.70
Undervoltage Trip for
GJL Circuit Breaker
Alarm/Auxiliary Switch for
GJL Circuit Breaker
Shunt Trip for
GJL Circuit Breaker
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
(Note-If part # has option see page 18. Ex: FAL220801021)
6-37
qDE2A DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Mechanical Accessories
UL Listed
Class 690
Electrical Operators
Provides remote ON, OFF/RESET control of molded case circuit breakers.
kA complete line of field-installable electrical operators.
kNot applicable on LE/LX/LXI, ME/MX or NE/NX circuit breakers.
kInstalling side mounted motor operators on non I-LINE® circuit breakers requires the
use of a separate mounting pan.
kSide mounted electrical operators require an additional 412 in. (114mm) of mounting
space in I-LINE® installations.
Circuit
Breaker
Prefix
Top Mount Side Mount Mounting Pan
Voltage Catalog No. Price Voltage Catalog No. Price Catalog No. Price
FA, FH, FC . . . . . . . . . 120 Vac FAMO1 $ 828. . . . . . .
FAL, FHL,
FCL . . . . . . . . . 120 Vac FAMO1 828. FAMOP $ 69.
FI, KA, KH,
KC, KI . . . . . . . . . 120 Vac KAMO1 2226. . . . . . .
FIL, KIL,
KAL, KHL,
KCL
120 Vac KAMO2120AC $2312.
120 Vac KAMO1 2226. KAMOP 85.
240 Vac KAMO2240AC 2312.
24 Vdc KAMO224DC 2312.
125 Vdc KAMO2125DC 2312.
LA, LH, Q4 . . . . . . . . . 120 Vac LAMO1 2869. . . . . . .
LAL, LHL,
Q4L
120 Vac LAMO2120AC 2987.
120 Vac LAMO1 2869. LAMOP 117.
240 Vac LAMO2240AC 2987.
24 Vdc LAMO224DC 2987.
125 Vdc LAMO2125DC 2987.
MA, MH . . . . . . . . . 120 Vac MAMO1 2869. . . . . . .
MAL, MHL
120 Vac MAMO2120AC 2987.
120 Vac MAM01 2869. MAMOP 117.
240 Vac MAM02240AC 2987.
24 Vdc MAM0224DC 2987.
125 Vdc MAM02125DC 2987.
PA, PH, PC,
PE, PX 120 Vac PAMO2 3520. . . . . . . . . . . . . . . .
Handle Accessories
Breaker Prefix No. of
Poles Catalog No. Price
Handle Lock-Off (locks ON or OFF)
QO
QO, QOU 1
1,2,3 QO1LO
HLO1 $2.40
6.30
EH(60A max.) 1,2,3 HLOEH 6.90
Handle Padlock Attachment (locks ON or OFF)
QOU
QOU
QOM1
QOM2
1
2,3
2
2
QOU1PA
QOU1PL
QOM1PA
QOM2PA
6.40
6.40
6.90
6.90
QO(loose)
QO(fixed)
QO(loose)
QO(fixed)
QO-GFI(fixed)
1
1
2,3
2,3
2
QOHPL
QO1PA
QO1HPL
QO1PL
GFI2PA
6.00
6.80
6.80
6.80
5.80
EH(15-100A) 1,2,3 HPAEH 6.90
Breaker Prefix No. of
Poles Catalog. No. Price
Handle Tie
(2)FA 3 FKHT $136.00
(2)KA,
(2)FI,(2)KI, or
(1)FI + (1)KI 2,3 FKHT 136.00
(2)LA or
(2)Q4 2,3 LAHT 315.00
(2)QO 1 QO1HT 2.40
(2)QOT - QO1HT 2.40
(2)QO 3 QO3HT 8.50
California Title 24
Comb. Handle Tie and Lock Off
FY
FA (3)1-Pole
(3)1-Pole FY3HT
FA3HT 33.10
33.10
See Pages 6-47–6-50 for Enclosures.
Fully enclosed interlocked units are available in Type 1 and Type 3R enclosures, with two neutrals provided in each
enclosure.The completely enclosed assembly is not UL Listed. Please consult your nearest Square D/Schneider
Electric sales office for more information.
Walking Beam Mechanical Interlock Components
Circuit Breaker Price
Adder
Walking Beam Ass'y. Mounting Pan
Prefix Suffix Catalog No. Price Catalog No. Price
Manually Operated
FAL, FHL
KAL
LAL, LHL
MAL, MHL
WB
WB
WB
WB
$164.
164.
164.
164.
FA4WB
KA4WB
LA6WB
MA9WB
$ 85.
85.
113.
136.
FAWBP4
KAWBP4
LAWBP6
MAWBP9
$112.
112.
153.
196.
Electrically Operated
FAL, FHL
KAL
LAL, LHL
MAL, MHL
WBMO
WBMO
WBMO
WB
$164.
164.
164.
164.
FA9WB
KA9WB
LA10WB
MA13WB
$127.
127.
135.
159.
FAWBP9
KAWBP9
LAWBP10
MAWBP13
$153.
153.
196.
272.
When remote indication of circuit breaker status is required, order circuit
breaker with 1A-1B auxilliary switch for ON-OFF Indication and alarm switch
for TRIP Indication. Electrical operators require SPDT maintained contact
switch. Refer to Class 9001 control unit listing for operators and pilot lights.
Wiring Diagram for
Side Mount Electrical Operator
Cylinder Lock
Used to lock the circuit breaker in the OFF position.
Circuit breaker cannot be reset when locked OFF.
cNot available on MAG-GARD circuit breakers and molded case
switches.
Circuit
Breaker
Prefix
Catalog Number
Price
Factory Inst.
Suffix Field Inst.
FA, FAL, FH, FHLc—CL Factory Installed
Only
$200.
KA, KAL, KH, KHLc200.
LA, LAL, LH, LHL, Q4 Field Installable
Only
LA1CL 200.
MA, MAL, MH, MHL MA1CL 200.
fMA, MH, ME, and MX circuit breakers will not lock in ON position.
dUse with MAHEX handle extension.
Circuit Breaker
Prefix No. of
Poles Catalog No. Price
Handle Padlock Attachment (locks ON or OFF)
FY Series 1
Q2 1
2,3 HPAFYQ
HPAFYQ $12.60
FA, FH, FC, FI
FY Series 2, KA, KH,
KC, KI
1,2,3
2,3 HPAFK
HPAFK 15.30
LA, LH, MA, MH,
ME, MX, Q4 2,3 HPALMf
HPAXLMd16.50
17.50
NA, NC, NE, NX 2,3 HPANE 16.50
LC, LE, LI, LX, LXI 2,3 AHPALI 16.00
Handle Extension
MA, MH, ME, MX,
NA, NC, NE, NX 2,3 MAHEX 60.00
LA, LC, LH, LE, LI,
LX, LXI, Q4 2,3 AHEXLI 60.00
Walking Beam Mechanical Interlock
Requires two circuit breakers with WB suffix,
one walking beam assembly and one mounting pan.
ELECTRICAL
OPERATOR (OFF/RESET)
(ON) SPDT
(by Customer)
120VAC
FAMO1 and FAMOP
With FAL Circuit Breaker
KAMO2120AC
With KAL Circuit Breaker
QO and I-LINE are Registered Trademarks of Square D Company or related companies.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-38 DE2 Discount
Schedule 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Electrical Accessories
UL Listed
Class 690
Electrical accessories are available on all molded case circuit breakers except FY, Q2, QOM1 and QOB-VH (2-pole 150 A and 3-pole 110-150 A) circuit
breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Add 20% to accessory price for each field-installable accessory that is
factory installed. See Page 6-39 for field-installable accessories.
Molded Case Circuit Breakers
Factory-installed Electrical Accessories
Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on EH, EH-PL, QO, QO-GFI, QO-EPD, QO-SWN, QOU and QO-PL circuit
breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for Q2, QOM1 and QOB-VH (2-pole 150 A
and 3-pole 110-150 A) circuit breakers or QO molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. EH/EHB
circuit breakers will accept multiple accessories. Undervoltage trip is not available on miniature circuit breakers.
Accessory Description Rated
Voltage Coil
BurdenjSuffix List Price
Addert
SHUNT
TRIP Trips the circuit breaker from a remote location by means of a trip coil
energized from a separate circuit. A 120 V shunt trip will operate at 55%
or more of rated voltage. All other shunt trips will operate at 75% or more
of rated voltage.
Application
For use with momentary or maintained push button.
Sure Trip Capacitor Unit requires 48 Vdc shunt trip.
Leads: (2) Black #18 AWG Cu.
AC 24 21VA -1042c$ 479.
120 24VA -1021a479.
208 107VA -1021 479.
240 154VA -1021 479.
277 14VA -1037c479.
480 45VA -1037 479.
DC 24 36VA -1027 479.
48 36VA -1028 479.
125 44VA -1029 479.
250 15VA -1030q479.
GROUND-
FAULT
SHUNT
TRIP
Trips the circuit breaker electrically using the signal from a
MICROLOGIC® Ground-Fault Module.
Application
For use only with obsolete GP GROUND-CENSOR® system or add
on ground-fault module.
Leads: (2) Orange #18 AWG Cu.
. . . . . . -Gq479.
UNDER
VOLTAGE
TRIP
Trips the circuit breaker electrically when a control circuit falls below 35
to 70% of nominal (not field adjustable). Picks up at 35-85% of nominal
voltage.
Application
UVR must be energized in order to close the circuit breaker.
Leads: (2) Brown #18 AWG Cu leads.
AC 24
120
240
DC 24
DC 48
5 VA
8 VA
8 VA
2 VA
3 VA
-1143qf
-1121
-1124f
-1127f
-1128f
479.
479.
479.
479.
479.
TIME
DELAY
UNIT
Provides adjustable time delay for UVR of 0.1 to 0.6 second before
circuit breaker trips.
Application
For use only with -1121 UV trip.
Adjustable time delay (0.1 to 0.6 second).
I-LINE unit requires 1.5 in. (38 mm) of mounting space.
Leads: (2) Brown #18 AWG Cu and (2) Black/White #18 AWG Cu.
AC 120 Catalog No.
Unit Mt. I-LINE
690UVTD 690UVTDI 1232.
AUXILIARY
SWITCHES Monitors circuit breaker contact status and provides a remote signal indicating
the circuit breaker contacts are OPEN or CLOSED.
Application
Max. Load = FA, FH, FC, FI, KA, KH, LC, LE, LI, LX, LXI.
10A @ 125-250 Vac
14 hp @ 125-250 Vac, 5A @ 30 Vdc
Leads: Yellow for “A’’, Blue for “B’’, Striped for common
#18 AWG Cu.
See
load
info. in
App.
text
at left
See
load
info. in
App.
text
at left
1A/1B -1212 198.
2A/2B -1352 395.
3A/3B -1364b508.
ALARM
SWITCHES Used with control circuits and actuated only when the circuit
breaker has tripped. Standard construction includes a normally
open contact.
Application
Max. Load = 10 A @ 125-250 Vac
Max. Load = 15 A @ 30 Vdc
Leads: (2) Red #18 AWG Cu.
1A
1A
1B
1B
AC 250
DC 28
AC 250
DC 28
See
load
info. in
App.
text
at left
-2100
-2100
-2103
-2103
198.
198.
198.
198.
Accessory Description Rated
Voltage Coil
Burden Suffix List Price
Adder Accessory Description Contact
Comb. Max.
Voltage Max.
Load Suffix List Price
Adder
SHUNT
TRIP Trips the circuit breaker from a
remote location by means of a trip
coil energized from a separate
circuit. A 120 V shunt trip will
operate at 55% or more of rated
voltage. All other shunt trips will
operate at 75% or more of rated
voltage.
Application
For use with momentary or
maintained push button.
Not available on QO-GFI,
QO-EPD.
Shunt trip terminals accept (2)
#14-#12 AWG Cu.
Leads: EHB circuit breakers
have (2) Black #16 AWG Cu.
QO Circuit Breakers AUXILIARY
SWITCHES Monitors circuit breaker contact status
and provides a remote signal indicating
the circuit breaker contacts are OPEN
or CLOSED.
Application
Auxiliary switch terminals accept
(2) #14-#12 AWG Cu leads.
Leads (EH): Yellow for “A’’, Blue for
“B’’, Striped common #18 AWG Cu.
QO Circuit Breakers
AC/DC
1A
1B AC 120
AC 120 5A
5A -1200
-1201 $ 84.
84.
12 60VA -1042 $120.
24 168VA -1042
AC 120 72VA -1021 120.
208 228VA -1021
240 288VA -1021
EH/EHB Circuit Breakers EH/EHB Circuit Breakers
AC/DC 1A/1B AC 277 5A -1212 198.
12 60VA -1042 479.
24 168VA -1042
ALARM
SWITCHES
Used with control circuits and is
actuated only when the circuit breaker
has tripped. Standard construction
includes a normally-open contact.
Application
Leads: EHB circuit breakers have
(2) Red #18 AWG Cu.
Alarm switch terminals accept
(2) #14-#12 AWG Cu leads.
QO Circuit Breakers
AC 120 72VA -1082
208 218VA -1082 479. 1A AC 120 5A -2100 84.
240 288VA -1082
277 416VA -1082 EH/EHB Circuit Breakers
QO M2
1A AC 277 5A -2100 198.
AC240 168VA -1021 120.
QO, GROUND-CENSOR and MICROLOGIC are Registered Trademarks of Square D Company or related companies.
Note:
Alarm switch is the only accessory
available for 1-pole FA circuit
breakers.
Combination accessories may be
ordered by description, i.e., 1021
and 1212.
cNot available on FI, KI or KC
circuit breakers.
qNot available on LC, LE, LI, LX,
LXI circuit breakers.
fNot available on ME or MX circuit
breakers.
aLC, LE, LI, LX, and LXI circuit
breakers operate at 75% or more
of rated voltage.
bNot available in FA, FC, FH, FI
and KI circuit breakers.
jCoil burden values do not apply
to LC, LE, LI, LX and LXI. Consult
Field Sales Office for more infor-
mation.
tList price for field-installed acces-
sories. See Page 6-39.
1-pole QO with Shunt Trip
Time
Delay
Unit
690UVTD
SQUARE D
CIRCUIT BREAKER
with 120Vac 50/60 Hz
60mA Undervoltage Trip
Black Wire 120Vac
White Wire Neutral
Brown Wire
Brown Wire
690UVTD Wiring Diagram
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-39
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Accessories
Field-installable
Class 690
Complete field-installable accessory catalog number by inserting suffix from previous
page between the parentheses in the catalog numbers shown in the table below.
(Example: LA11212) See Page 6-38 for accessory pricing; add 20% to factory install field-
installable devices.
qCombination accessory in right pole with factory-installed alarm switch must also be factory installed on MA circuit
breaker.
aUsed with obsolete GP GROUND-CENSOR® system or add on ground-fault modules.
fWith LA and LH top-feed I-LINE® circuit breakers (suffix [MT] I-LINE® jaws on OFF end) all accessories must be
factory installed.
Accessory Mounting Locations
LA, LH, Q4 Series 4 circuit breakers or newer = Field-installable
accessories
LC, LI, LE, LX, LXI circuit breakers = Field-installable accessories
MA, MH Series 2 circuit breakers or newer = Field-installable
accessories
ME, MX circuit breakers = Not Field-installable accessories
Both ports will accept shunt trips, UVRs and auxiliary switches.
Alarm switches are factory installable only (right pole). Maximum of
one device per port.
NA, NC, NE, NX circuit breakers = Field-installable
accessories
“L port and “R1” port will accept shunt trips, alarm
switches and UVRs; “R2” port will accept auxiliary
switches. Maximum of one device per port.
Field-installable Electrical Accessories
Accessory Shunt Trip Ground-fault
Shunt TripaUndervoltage
Trip Auxiliary
Switches Alarm Switch
Miniature Circuit
Breakers
EH and EH-PL
Factory
Installed Only Not
Available Not
Available Factory
Installed Only Factory
Installed Only
FA, FH,
FC, FI,
KA, KH,
KC, KI
Factory Installed Only
LA, LH,
Series 4fLA1( ) LA1G LA1( ) LA1( ) Factory
Installed Only
Right Pole
Q4 LA1( ) LA1G LA1( ) LA1( ) Factory
Installed Only
Right Pole
MA, MH
Series 2 MA1( ) MA1G MA1( ) MA1( ) Factory
Installed Only
Center Poleq
LC, LE, LI, LX,
LXI LC1( ) Not Available LC1( ) LC1( ) Factory
Installed Only
ME, MX Factory Installed Only
NA, NC, NE, NX
Series 1, 2, 3 NA1( ) NA1G NA1( ) NA1( ) NA1( )
PA, PH, PC
Series 4 PA1( ) Factory
Installed Only PA11121
PA11124 PA1( ) Factory
Installed Only
PE, PX
Series 4, 5, 6 PA1( ) Factory
Installed Only PA11121
PA11124 PA1( ) Factory
Installed Only
GROUND-CENSOR and I-LINE are Registered Trademarks of Square D Company.
PA, PH, PC, PE, PX Series 4 circuit breakers or newer =
Field-installable accessories
“L1” and “L2” or “R1” and “R2” port combinations are required
to mount a single shunt trip. Both “L2” and “R2” ports will
accept a UVR. Both “L1” and “R1” ports will accept auxiliary
switches. If alarm switch is factory installed in PA or PC circuit
breaker, it will be installed in “R2” port. For a PE or PX circuit
breaker, the alarm switch will be factory installed in “L2” port.
Circuit Breaker Open or Closed
1A/1B
Circuit Breaker Closed
AB
Circuit Breaker Open or Tripped
AB
1A Alarm Switch
Configuration
Color Code: Red Leads
Circuit Breaker Tripped
Auxiliary Switch
Contact Configuration
Color Code:
"A" Contact-Yellow Leads
"B" Contact-Blue Leads
Common-Striped Leads
Undervoltage Trip
Wiring Diagram
Brown
Brown
Brown Wires To Be
Connected To
Control Power
Shunt Trip
Wiring Diagram
Black
Black
Black Wires To Be
Connected To
Control Power
UVR
Shunt
Trip
Circuit Breaker Tripped
1B Alarm Switch
Configuration
Color Code: Red Leads
Circuit Breaker Open or Closed
L
R
LR1
R2
L1
L2
R1
R2
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-40 DE2 Discount
Schedule 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Mechanical Lugs
Class 690
kAll P-frame circuit breakers require terminal pads for mounting lugs of any type. See table at bottom of the page.
fUnless otherwise specified, wire sizes apply to both aluminum and copper conductors.
aFor use in the OFF end only, when the OFF end is the load end.
tContact your nearest Square D/Schneider Electric sales office for current prices.
Mechanical Lug Kit Information
Circuit Breaker Application Number of Wires
Per Lug and
Wire Rangef
Kit
Catalog
Number
Lugs
Per
Kit
Price
Per Kit
Standard Ampere
Rating Optional Ampere
Rating
Al Lugs for Use with Al or Cu Wire
EDB, EGB, EJB,
FD, FG, FJ 15-30 . . . . . . . . 1—#12-#6 AWG Al or
1—#14-#6 AWG CU AL30FD 3 $ 26.20
EDB, EGB, EJB,
FD, FG, FJ 35-125 EDB, EGB, EJB,
FD, FG, FJ 15-30 1—#12-#2/0 AWG Al or
1—#14-#2/0 AWG CU AL100FD 3 26.20
FA, FH
FI 15-30 FA, FH
FI 35-100 1—#14-#4 AWG Cu or
1—#12-#4 AWG Al AL50FA 3 23.60
FC 35-100 FC 15-30 1—#14-#3 AWG Cu or
1—#12-#1 AWG Al AL100FA4 3 23.60
FA, FH
FI 35-100 FA, FH
FI 15-30 1—#14-#1/0 AWG Cu or
1—#12-#1/0 AWG Al AL100FA 3 23.60
. . . . . . . FA, FH, FC 15-100 1—#12-#3 AWG Cu AL100TF323.60
. . . . . . . . FA 150
(only) 1 —#1/0 #2/0 AWG AL150FA 3 23.60
ME, MX 100-250 . . . . . . . 1—#6 AWG-350 kcmil AL250ME 3 71.00
KA, KH 70-250 . . . . . . . 1—#4 AWG-350 kcmil AL250KA 3 71.00
KI, KC 110-175 . . . . . . .
KD, KG 100-250 . . . . . . 1—#6 AWG-350 kcmil AL250KD 3 68.00
KI, KC 200-250 KI 110-175 1—#1/0 AWG-350 kcmil AL250KI 3 68.00
Q4, LA, LH 125-400 . . . . . . . 1—#1 AWG-600 kcmil or
2—#1 AWG-250 kcmil AL400LA 1 22.70
. . . . . . . Q4, LA, LH 125-400 1—350-750 kcmil AL400LH7 1 29.90
LE, LX, LXI 100-250 LC, LI, LE, LX,
LXI . . . 2—#1 AWG-350 kcmil AL600LI35 1 24.00
LC, LI, LE, LX, LXI 300-600 LE, LX, LXI 100-250 2—#4/0 AWG-500 kcmil AL600LI5 1 29.90
. . . . . . . LC, LI, LE, LX,
LXI . . . 1—500-750 kcmil AL600LI7 1 29.90
. . . . . . . ME, MX 250-400 1—350-750 kcmil AL400ME7 1 29.90
. . . . . . . MA, MH 300-1000 2—500-750 kcmil AL800MA7 1 88.00
. . . . . . . ME, MX 100-800
MA, MH 300-1000 . . . . . . 3—#3/0 AWG-500 kcmil AL900MA 1 60.00
ME, MX 300-800 ME, MX 100-250
. . . . . . . MA, MH, ME, MX 300-1200 4—#1/0 AWG-350 kcmil AL1000MA 1 60.00
NA, NC, NE, NX 600-1200 . . . . . . . 4—#3/0 AWG-600 kcmil AL1200NE6 1 136.00
. . . . . . . PAF, PHF, PEF
PXF, PCF 600-2500 1—#1/0 AWG-750 kcmil AL2500PAk284.00
Cu Lugs for Use with Cu Wire Only
. . . . . . EDB, EGB, EJB,
FD, FG, FJ 15-125 1—#14-#1/0 AWG Cu CU100FD 3 26.20
FC 15-30 . . . . . . . 1—#14-#10 AWG Cu CU30FA4 3 23.60
. . . . . . . FA, FH, FC, FI 15-100 1—#14-#1 AWG Cu CU100FA 3 23.60
. . . . . . . FA, FH, FC 15-100 1—#12-#3 AWG Cu CU100TFa323.60
. . . . . . . KA, KH 70-250 1—#4 AWG-250 kcmil Cu CU250KA 3 71.00
. . . . . . . KC, KI 110-250
KD, KG 100-250 . . . . . . 1—#6 AWG-350 kcmil CU250KD 3 71.00
. . . . . . . ME, MX 125-250 1—#4 AWG-250 kcmil CU250ME 3 71.00
. . . . . . . Q4, LA, LH 125-400 1—#1 AWG-600 kcmil Cu or
2—#1 AWG-250 kcmil Cu CU400LA 1 23.70
. . . . . . . LC, LI, LE, LX,
LXI . . . 2—#1 AWG-350 kcmil CU600LI35 1 25.10
. . . . . . . LC, LI, LE, LX,
LXI . . . 2—#4/0 AWG-500 kcmil CU600LI5 1 29.90
. . . . . . . LC, LI, LE, LX,
LXI . . . 1—500-750 kcmil CU600LI7 1 29.90
. . . . . . . ME, MX 100-800 3—#3/0 AWG-500 kcmil Cu CU1000MA 1 60.00
. . . . . . . MA, MH 300-1000
. . . . . . . NA, NC, NE, NX 600-1200 4—#3/0 AWG-600 kcmil Cu CU1200NE6 1 348.00
Terminal Pad Kits for PA, PH, PC, PE and PX Circuit Breakers
Circuit Breaker Prefix Terminal Pad Kit
Catalog Number Price
PAF, PHF, PXF-12, PEF-12, PXF-16, PXF-20, PEF-16 PALTB (See photo A at left) $580.00
PCF, PEF-20, PXF-25, PEF-25 Included with circuit breaker (See photo B at left) . . .
RGF, RJF, RLF RLTB t
AL50FA AL250KI
AL250KA
AL100FA
AL400LA AL600LI5 AL400LH7
AL900MA AL800MA7 AL1000MA
AL1200NE6 AL2500PA
PAF, PHF, PXF-12, PEF-12, PXF-16, PEF-16, and PXF-20 circuit breakers
can be bus or cable connected. For cable connections, optional terminal pad
kit PALTB or equivalent bus structure is required. Each PALTB kit contains
terminal pads for one end of the circuit breaker only and has provisions for
mounting a maximum of six lugs per phase. Order lugs separately. See this
page and Page 6-41.
PALTB
PCF, PEF-20, PXF-25 or PEF-25 circuit breakers are supplied with terminal
pads for both ends of the circuit breaker. The supplied terminal pads or
equivalent bus structure must be used for bus or cable connections. Terminal
pads have provisions for mounting a maximum of eight lugs per phase. Order
lugs separately. See this page and Page 6-41.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-41
DE2 Discount
Schedule
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
Molded Case – Lugs
Class 690
fUnless otherwise specified, wire sizes apply to both aluminum and copper conductors.
kAll P-frame circuit breakers require terminal pads for mounting lugs of any type. See Page 6-40.
tThese lug kits cannot be used on I-LINE® circuit breakers.
Power Distribution Connectors for Circuit Breakers — for Field Replacement of Mechanical Lugs
UL Listed Field-installable VERSAtile™ Lug Kits
Circuit Breaker
Type VERSAtile
System Rangef
Dimension
A
(In)
VERSA-
CRIMP®
Tool Type
Max.
Lugs
Per
Terminal
Kit
Catalog
Number
Lug
Qty.
Per Kit
Price
Per
Kit
Aluminum Compression Lug Kits
EDB, EGB, EJB,
FD, FG, FJ #8-#1/0 AWG 1.375 VC-6 Series 1 VC100FD 3 $ 65.
FA, FH, FC, FI #8-#1/0 AWG 1.3 VC-6 Series 1 VC100FA 3 65.
KA, KH, KC, KI #4 AWG-300 kcmil 1.5 VC-6 Series 1 VC250KA3 3 123.
KA, KH, KC, KI 250-350 kcmil 1.5 VC-6 Series 1 VC250KA35 3 123.
LA, LH, Q4 250-350 kcmil 1.25 VC-6 Series 2 VC400LA35 2 123.
LA, LH, Q4 #4 AWG-300 kcmil 1.0 VC-6 Series 2 VC400LA3 2 123.
LA, LH, Q4 #2/0 AWG-500 kcmil 2.2 VC-6 Series 1 VC400LA5 1 60.
LA, LH, Q4 500-750 kcmil Al or 500
kcmil Cu 2.5 VC-6 FT or
VC-8 1 VC400LA7 1 82.
LC, LI, LE, LX, LXIt#4 AWG-300 kcmil 1.05 VC-6 Series 2 VC600LI3 2 83.
LC, LI, LE, LX, LXIt#2/0 AWG-500 kcmil 3.20 VC-6 Series 2 VC600LI5 2 85.
LC, LI, LE, LX, LXIt500-750 kcmil 3.45 VC-6FT or
VC-8C 1 VC600LI7 1 85.
ME2, MX2 #4 AWG-300 kcmil 1.5 VC-6 Series 1 VC250ME3 3 123.
ME2, MX2 250-350 kcmil 1.5 VC-6 Series 1 VC250ME35 3 123.
ME4, MX4 #2/0 AWG-500 kcmil 2.2 VC-6 Series 1 VC400ME5 1 60.
ME4, MX4 500-750 kcmil Al or 500
kcmil Cu 2.5 VC-6 FT or
VC-8 1 VC400ME7 1 82.
MA, MH, ME, MX #2/0 AWG-500 kcmil 1.9 VC-6 Series 2 VC600MA5 2 186.
MA, MH, ME, MX 500-750 kcmil Al or 500
kcmil Cu 2.1 VC-6 FT or
VC-8 2 VC800MA7 2 198.
NA, NC, NE, NX #2/0 AWG-500 kcmil 3.3 VC-6 Series 4 VC1200NE5 4 598.
NA, NC, NE, NX 500-750 kcmil Al or 500
kcmil Cu 3.6 VC-6 FT or
VC-8 4 VC1200NE7 4 598.
PAF, PHF, PXF, PEFk#2/0 AWG-500 kcmil kVC-6 Series 6-8 VC2000PA5 1 61.
PAF, PHF, PCFk
PXF, PEF 500-750 kcmil Al
or 500 kcmil Cu kVC-6 FT or
VC-8 6-8 VC2500PA7 2 61.
Copper Compression Lug Kits
EDB, EGB, EJB,
FD, FG, FJ #6-#1/0 AWG 1.375 VC-6 Series 1 CVC100FD 3 $ 65.
FA, FH, FC, FI #6-#1/0 AWG Cu 1.4 VC-6 Series 1 CVC100FA 3 65.
KA, KH, KC, KI #2/0 AWG-300 kcmil Cu 1.5 VC-6 Series 1 CVC250KA3 3 124.
LA, LH, Q4 #2/0 AWG-300 kcmil Cu 1.3 VC-6 Series 2 CVC400LA3 2 124.
LA, LH, Q4 250-500 kcmil Cu 2.3 VC-6 Series 1 CVC400LA5 1 60.
LC, LI, LE, LX, LXIt250-500 kcmil 3.20 VC-6 Series 1 CVC600LI5 1 85.
ME4, MX4 250-500 kcmil Cu 2.6 VC-6 Series 1 CVC400ME5 1 60.
MA, MH, ME, MX 250-500 kcmil Cu 2.4 VC-6 Series 2 CVC600MA5 2 186.
NA, NC, NE, NX 250-500 kcmil Cu 3.3 VC-6 Series 4 CVC1200NE5 4 599.
NA, NC, NE, NX 500-750 kcmil Cu 3.6 VC-6 Series 4 CVC1200NE7 4 599.
Can be used for multiple load connections on one circuit breaker. Use in place of
standard distribution blocks to save space and time.
Field-installable kits, including tin plated aluminum connectors and all necessary
mounting hardware are available for Square D FA, KA, LA, Q4, MA, ME and MX
molded case circuit breakers.
Connectors are UL Listed:
For use on OFF end of circuit breaker when the OFF end is the load end.
For use in UL508 Industrial Control applications only.
For copper wire only.
qNot for use with I-LINE mounted circuit breakers.
uWhen using fine stranded wire, increased cross sectional area may cause maximum wire size to be reduced.
Use
With
Circuit Breakerq
Cicuit
Breaker
Ampere
Rating
Number of Wires
Per Terminal
& Wire Rangeu
Catalog
Number
Lug
Quantity
Per Kit
Dimension
A
(In.)
Price
Per
Kit
FAL, FHL, FCL 15-100 6-#14-#6 AWG Cu PDC6FA6 3 1.0 $ 58.
15-100 3-#14-#2 AWG Cu PDC3FA2 3 1.2 58.
KAL, KHL
70-250 6-#14-#4 AWG Cu PDC6KA4 3 1.0 109.
70-250 2-#14-#1 AWG Cu
1-#12-#2/0 AWG Cu PDC3KA20 3 1.5 109.
LAL, LHL, Q4L
125-400 6-#12-#2/0 AWG Cu
12-#14-#4 AWG Cu PDC6LA20
PDC12LA4 1
12.25
1.25 82.
125-400 3-#14-#2 AWG Cu
1-#2-250 kcmil Cu PDC4LA250 1 2.0 82.
MAL, MHL,
MEL, MXL 125-1000 6-#12-#2/0 AWG Cu
12-#14-#4 AWG Cu PDC6MA20
PDC12MA4 1
10.0
0.0 82.
FAL Circuit Breaker
With Three PDC6FA6 Installed.
MAL Circuit Breaker
With Three PDC6MA20 Installed
CVC100FA VC250KA3 CVC400LA5 VC400LA7
PDC6FA6
PDC6KA4
PDC12LA4
VERSA-CRIMP and I-LINE are Registered Trademarks of Square D Company.
VERSAtile is a Trademark of Square D Company.
Extremity
of
Molded Case
w/Mechanical
Lugs
“A” See Table
Crimp lug or
power distribution connectors
extension past
end of
circuit breaker
“A” See Table
VC1200NE5
CVC600MA5
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-45
3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
C/L C/L
A
BE
BEBE
BE
G
B
A
GA
GA
A
D
C
D
C
FB
G
EBE BE
A
G
A
GA
G
D
C
Figure 4
Figure 6
Figure 21 Figure 24 Figure 25 Figure 26
NC100
Figure 22 Figure 23
Figure 10
Figure 13 Figure 14 Figure 15 Figure 16
Figure 17 Figure 18 Figure 19 Figure 20
Figure 11 Figure 12
EH, EHB
Figure 7 Figure 8 QOU, QYU
Low Ampere
QOU
High Ampere
Figure 9
QO-PLPS
Figure 5 QO-GFI
QO-PL
QO-EPD
Figure 2Figure 1 Figure 3 QO, QOB
A
G
B
E
D
C
A
BE BE
A
BE
A
D
C
BB
B
D
C
G
HH
EEE
E
E
FAFAFA
E
G
A
A A A A
A A A
C
D
C
D
FB
C
D
C60
A
BE
A
BE
A
BE
B
B BBB
B B B E
E
Dimensions
Class 600
QO is a Registered Trademark of Square D Company or related companies.
MULTI 9 is a Trademark of Schneider Electric.
u70-100 A is 4.00 in.
q35-70 A is 3.12 in; 80-100 A 2-pole and 70-100 A 3-pole are 3.50 in.
cQO-PL is 4.55 in.
a80-100 A 1-pole and 80-125 A 2-pole are 4.45 in.
k70-100 A 4.45 in.
j80-100 A 1-pole and 80-125 A 2-pole are 6.78 in.
t70-100 A is 6.78 in.
aDimensions E 1.59 in at ON end and 0.63 in at OFF end.
pFCL 2-pole circuit breaker dimension B is 4.50 as in Fig. 26.
QO, QOU, EH Circuit Breakers
Circuit Breaker
Catalog No.
Prefix
No.
Poles Fig.
No.
Dimensions - Inches
ABCDEFG
QO, QOB
1 1 0.75 3.00q2.31 2.91 2.25 . . . 0.59
2 2 1.50 3.00q2.31 2.91 2.25 . . . 1.34
3 3 2.25 3.00q2.31 2.91 2.25 . . . 2.09
QOB-VH 150A
QOB-VH 110-150A
2 2 3.0 5.72 2.53 4.90 3.78 . . . 2.85
3 3 4.50 5.72 2.53 4.90 3.78 . . . 4.35
QO-PL
QO-GFI
QO-EPD
1 4 0.75 4.12c2.31 2.91 2.25 . . . 0.59
2 5 1.50 4.12c2.31 2.91 2.25 . . . 1.34
3 5 2.25 4.12c2.31 2.91 2.25 . . . 2.09
QOU
QYU
Low Ampere
1 6 0.75 4.05a2.38 2.98 2.25 5.00j0.62
2 7 1.50 4.05a2.38 2.98 2.25 5.00j1.37
3 8 2.25 4.05k2.38 2.98 2.25 5.00t2.12
QOU
High Ampere
1 10 0.75 4.45 2.37 2.96 2.25 6.78 . . .
2 11 1.50 4.45 2.37 2.96 2.25 6.78 . . .
3 12 2.25 4.45 2.37 2.96 2.25 6.78 . . .
MULTI 9 C60N
1 13 0.71 3.19 1.73 2.76 1.77 . . . . . .
2 14 1.42 3.19 1.73 2.76 1.77 . . . . . .
3 15 2.13 3.19 1.73 2.76 1.77 . . . . . .
4 16 2.84 3.19 1.73 2.76 1.77 . . . . . .
MULTI 9 NC100
1 17 1.06 3.19 1.73 2.76 1.77 . . . . . .
2 18 2.13 3.19 1.73 2.76 1.77 . . . . . .
3 19 3.19 3.19 1.73 2.76 1.77 . . . . . .
4 20 4.25 3.19 1.73 2.76 1.77 . . . . . .
QO-PLPS
Power Supply 2 9 1.45 4.35 2.42 3.11 . . . . . . . . .
EH, EHB
1 21 1.00 3.50 2.00 2.97 2.44 . . . . . .
2 22 2.00 3.50u2.00 2.97 2.44 . . . . . .
3 23 3.00 3.50u2.00 2.97 2.44 . . . . . .
Q2, Q4, FA, FI, KA, KI, LA,
MA, ME and MX Circuit Breakers
Circuit
Breaker
Catalog No.
Prefix
No.
Poles Fig.
No.
Dimensions - Inches
A B CDEFGH
Q2L, Q2L-H 2 25 6.44 3.00 3.16 3.92 a4.25 . . . . . .
3 26 6.44 4.50 3.16 3.92 a4.25 1.50 0.75
FAL,
FHL,FCLp
1 24 6.00 1.50 3.16 4.13 0.44 5.13 1.50 . . .
2 25 6.00 3.00p3.16 4.13 0.44 5.13 . . . . . .
3 26 6.00 4.50 3.16 4.13 0.44 5.13 1.50 0.75
FIL, KAL,
KHL, KCL, KIL 2 & 3 26 8.00 4.50 3.66 4.75 0.44 7.13 1.50 0.75
Q4L, LAL, LHL 2 & 3 26 11.00 6.00 4.06 5.84 0.88 9.25 2.00 1.00
MAL, MHL 2 & 3 26 14.00 9.00 4.53 6.50 1.66 10.69 3.00 1.50
MXL, MEL 2 & 3 26 14.75 9.00 4.37 6.50 1.66 11.43 3.00 1.50
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
6-46 3/00
© 2000 Square D
All Rights Reserved
6CIRCUIT BREAKERS
B
G
E
E
FA
B
G
AE
DC
D
C
Figure 27
Figure 28
Figure 29
DC
F
G
A
B
F
E
Figure 33
Figure 34
A
D
C
A
EB
EB
C
D
A
AA
EBBEEB
C
D
Figure 30 Figure 31 Figure 32
F
E
E
A
DC
G
B
Figure 35
G
B
F
EA
DC
Figure 36
Dimensions and Shipping Weights
Class 500, 600
LC, LI, LE, LX, LXI, NA, NE, NX, PA, PC, PE, and PX Circuit Breakers
Circuit Breaker
Catalog No.
Prefix
No.
Poles Fig.
No.
Dimensions - Inches
ABCDEFG
LC, LI, LE, LX,
LXI 2 & 3 27 11.86 7.50 5.48 6.74 0.55 10.75 2.50
NA, NC, NX, NE 2 & 3 27 12.12 14.98 6.40 8.07 1.69 8.75 5.00
PA, PH, PX, PE 2 & 3 28 20.06 13.70 7.25 10.47 14.00 12.00 12.75
PC, PX-25,
PE-20-25 2 & 3 29 26.10 23.30 13.33 16.55 14.10 12.00 . . .
ED, EG, EJ, KD, KG and GJ Circuit Breakers
Circuit
Breaker
Catalog No.
Prefix
No. of
Poles Fig. No.
Dimensions — Inches
ABCDE
ED, EG, EJ
1 30 0.98 5.66 3.09 4.05 3.32
2 31 1.96 5.66 3.09 4.05 3.32
3 32 2.94 5.66 3.09 4.05 3.32
KD, KG 2, 3 33 4.12 7.35 3.20 4.17 3.34
GJ 3 34 3.54 4.72 2.76 3.94 2.20
MG, MJ, PG, PJ, PL, RG, RJ and RL Circuit Breakers
Circuit
Breaker
Catalog No.
Prefix
No. of
Poles Fig.
No.
Dimensions — Inches
A BCDEF G
MG, MJ 2, 3 35 12.40 8.27 5.53 8.05 2.28 7.87 7.87
PG, PJ, PL 2, 3 35 16.29 8.27 5.53 8.05 4.19 7.87 7.87
RG, RJ, RL 2, 3 36 15.00 16.54 6.30 14.38 8.73 14.25 15.35
Frame Size Approx. Shipping
Weight (Lbs.)
ED, EG, EJ 1-pole 2
ED, EG, EJ 2-pole 3
ED, EG, EJ 3-pole 4
FAL
FHL 1-pole 2
FAL
FHL 2-pole
FCL 3
FAL
FHL 3-pole
FCL 5
FIL 8
GJ 3
KD
KG 5
KAL
KHL 7
KCL
KIL 9
LAL
LHL 15
LEL
LCL
LIL
LXL
25
MAL
MHL 34
MXL
MEL 44
NAL
NCL 49
MG
MJ 24
NXL
NEL 65
PAF
PHF 69
PG
PJ
PL 32
PXF
PEF 80
RG
RJ
RL 52
Q2L 4
Q4L 15
Frame Size Approx. Shipping
Weight (Lbs.)
All weights are for 3-pole circuit breakers