Product Detail Manual

2014-09-04

: Pdf 90273-Attachment 90273-Attachment 080083 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

Catalog #
Project
Comments
Prepared by
Type
Date
203 Cooper Circle P: 800-553-3879
Peachtree City, GA 30269 F: 800-954-7016
www.coopercontrol.com
Specifications:
Technology: Passive Infrared (PIR)
Power Requirements: 10-30 VDC from Greengate
Switchpack or Greengate System. Maximum current
needed is 25 mA per sensor.
Output:
• Open collector output to switch up to ten
Greengate Switchpacks
• Isolated Form C Relay in (-R models)
• Isolated Form C Relay Ratings: 1A 30 VDC/VAC
Time Delays: Self-Adjusting, 15 seconds/test, 5, 10,
15, 30 minutes
Light Level Sensing in (-R models):
0 to 300 foot-candles
Operating Environment:
• Temperature: 32°F to 104°F (0°C - 40°C)
• Relative humidity: 20% to 90%, non-condensing
• For indoor use only
Housing: Durable, injection molded housing.
Polycarbonate resin complies with UL 94V-0.
Size: 4.4” x 3.4” x 2” (112mm x 86.4mm x 50.8mm)
Mounting: Mounts directly to ceiling tile, to a 4”
square box and round mud ring or to a 4” octagon
box
LED Indicators: Red LED for PIR detection
OAWC-P,
Passive Infrared
Wall/Corner Sensor
• Self-Adjustingtimedelayandsensitivity
• Optionalbuilt-inlightlevelsensor
•OptionalBAS/HVACisolatedrelay
•NEMAWD7Guideroboticmethod
utilized to verify coverage patterns
•ManualONfeatureforusewith1or2
momentary switches controlling 1 or
more Switchpacks (GMD switch)
•SelectableWalk-ThroughMode
PIR
Activated Self-Adjusting
Overview
The Passive Infrared Low Voltage Occupancy Sensing Wall/Corner sensor is a
motion sensing lighting control that is used for energy savings and convenience.
Description/Operation
The sensor is designed to detect motion from a heat-emitting source (such as a
person entering a room) within its field-of-view and automatically switch lights ON.
These sensors have multi-segmented lenses. For units to sense motion, the person
must cross between two segments. The distance between segments increases
the farther you are from the sensor, so motion has to be larger the farther you
are from the unit. PIR sensors are considered line-of sight sensors, meaning that
the sensor must be able to have a direct line-of-sight to the person making the
motion. The sensor includes self-adaptive technology that continuously self-adjusts
sensitivity and time delay in real-time, maximizing the potential energy savings that
are available in the particular application. In Automatic On Mode, the lights turn
ON when a person enters the room. In Manual On Mode, the lights are turned
ON by activating a momentary switch (model # GMDS-*) that is connected to the
sensor. When used with 2 level lighting (-R model only), Bi-level Automatic On can
be achieved which allows Zone 1 to come on automatically upon occupancy. Zone
2 does not come on unless the occupant presses the optional momentary switch.
When enabled, the daylighting feature (-R models only) prevents lights from turning
ON when the room is adequately illuminated by natural light.
offices
conference rooms
storage areas
common areas
other indoor office
aisles/hallways
Catalog # Coverage
OAWC-P-120W 1200 sq. ft.
OAWC-P-120W-R 1200 sq. ft.
Field of View
wide angle, 120°
Features
w/BAS relay & Daylight Sensor
OAWC-P-009L-H-R 90 linear. ft.
OAWC-P-009L-H 90 linear. ft. 180°
w/BAS relay & Daylight Sensor
180°
wide angle, 120°
Application
Ordering
FCC Compliant
cULus Listed
RoHS Compliant
ACC131664
www.coopercontrol.com
203 Cooper Circle, Peachtree City, GA 30269
P: 800-553-3879 F: 800-954-7016
Cooper Controls, Greengate, Novitas, Yes Box, PCI Lighting Control Systems, VisionTouch, VisionSwitch,
MicroSet, Digita, ControlKeeper, LiteKeeper, TracKeeper, IntelliRelay are valuable trademarks of Cooper
Industries in the U.S and other countries. You are not permitted to use Cooper Trademarks without the
prior written consent of Cooper Industries.
16’
(4.9)
0
16’
(4.9)
6.8
(2.1 mm)
3 ft
(1 mm)
7 ft
(2.2 mm)
10 ft
(3 mm)
43 ft
(13.2 mm)
75 ft
(23 mm)
92 ft
(28 mm)
Coverage
Controls
PURPLE (NORMALLY CLOSED)
GRAY (ISOLATED RELAY COMMON)
ORANGE (NORMALLY OPEN)
MANUAL MODE OPERATION:
1. SWITCHES ARE REQUIRED TO TURN
CORRESPONDING LOADS ON.
2. LOADS TURN OFF WHEN SENSOR
TIMES OUT OR WITH SWITCHES.
AUTOMATIC MODE OPERATION:
1. WHEN SENSOR ACTIVATES, BOTH
LOADS TURN ON.
2. SWITCHES CAN BE USED TO TURN
LOADS ON OR OFF.
3. IF DAYLIGHT SENSOR IS ENABLED AND
LIGHT LEVEL IS ABOVE SETPOINT,
SWITCHPACK CONNECTED TO YELLOW
LEAD WILL NOT TURN LOAD ON.
RECOMMENDED WIRE:
18-3 AWG STRANDED WIRE SHIELDED OR
NON/SHIELDED
LOAD "A"
BLUE
NEUTRAL
HOT
**USE BLACK LEAD FOR 120 VAC.
USE ORANGE LEAD FOR 277 VAC.
CAP UNUSED LEAD.
LINE
**HOT
WHITE
BLUE
SWITCH-
PACK
LOAD "B"
BLUE
NEUTRAL
HOT
**USE BLACK LEAD FOR 120 VAC.
USE ORANGE LEAD FOR 277 VAC.
CAP UNUSED LEAD.
LINE
**HOT
WHITE
BLUE
SWITCH-
PACK
BLACK (COMMON)
BLUE (CONTROL)
RED (15 VDC)
MODEL GMDS - LOAD "B"
(NORMALLY OPEN
MOMENTARY SWITCH)
MODEL GMDS - LOAD "A"
(NORMALLY OPEN
MOMENTARY SWITCH)
BLACK (COMMON)
BLUE (CONTROL)
RED (15 VDC)
NOTES
1. LOADS MAY BE ON SAME
CIRCUIT OR DIFFERENT
CIRCUITS OR VOLTAGES.
2. SP20-MV SWITCHPACK SHOWN.
120/277 VAC 20AMP RATING.
BLACK (COMMON)
YELLOW (CONTROL-OCC/DAY)
BLUE (CONTROL-OCC)
RED (10-30 VDC)
BROWN/WHITE (YELLOW CONTROL)
BROWN (BLUE CONTROL)
Wiring Diagrams
Minor Motion, IR
Major Motion, IR
Maximum coverage area may
vary somewhat according to room
shape and the presence of obstacles.
19.4º
10 m
(33 ft)
0
10 m
(33 ft)
5 m
(16 ft)
5 m
(16 ft)
2.1 m
(10 ft)
15.3 m
(50 ft)
7.7 m
(25 ft)
4.6 m
(15 ft)
1.7 m
(6 ft)
Minor Motion, IR
Major Motion, IR
Maximum coverage area may
vary somewhat according to room
shape and the presence of obstacles.
19.4º
10 m
(33 ft)
0
10 m
(33 ft)
5 m
(16 ft)
5 m
(16 ft)
2.1 m
(10 ft)
15.3 m
(50 ft)
7.7 m
(25 ft)
4.6 m
(15 ft)
1.7 m
(6 ft)
Activation
3 4 PIR 5
1
9715-000004-00
Power Pack One Power Pack Two
(-R model only) (-R model only)
123456 78 910
DIP Switch Legend
DIP Switch Legend
Time DelayActivation PIR Sensitivity LEDs OverrideLighting Sweep Daylighting Mode
DIP Switch
Walk-Through Mode
Default =
Activation
*Self-Adjusts to
10 min. user
mode
1200 Sq. ft coverage 90 linear ft coverage
OAWC-P-120W-R, OAWC-P-009-H-R Models
*Wiring diagram for single sensor application.
Visit our website for other wiring diagrams.
OAWC-P, PIR Wall/Corner Sensor

Navigation menu