Product Detail Manual
102846-Catalog 102846-Catalog 102846-Catalog 051712 Batch5 unilog cesco-content
134468-Catalog 134468-Catalog 134468-Catalog Batch9 unilog cesco-content
2014-06-02
: Pdf 91712-Attachment 91712-Attachment 051712 Batch4 unilog
Open the PDF directly: View PDF .
Page Count: 240
Download | |
Open PDF In Browser | View PDF |
Bussmann ® Circuit Protection Solutions Bussmann ® Worldwide Circuit Protection Solutions World’s leading supplier of fuses and fusible protection systems, Bussmann continues its 88-year history of blazing new trails of innovative technologies. Maker of the industry’s first truly global product line, each item is backed by an efficient worldwide network of distribution, customer service and technical support. Bussmann products include the most extensive circuit protection solutions approved for use in a variety of major standards: UL, CSA, IEC. . . Not to mention both European (DIN, British Standard) and North American styled fuses for a wide range of applications: industrial motor protection, power conversion, medium voltage, power distribution, telecommunications network equipment, electronics, and automotive. Manufacturing operations in the U.S., Denmark, and the United Kingdom have earned ISO 9000 certification. Bussmann customers are assured of only the utmost quality across every product line. Knowledgeable. Responsive. Customer focused. Bussmann continues to set the standard for circuit protection solutions around the world. This catalog is intended to present product data and provide technical information that will help the end user with design application. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the user in all possible applications. ©2002 Cooper Bussmann Printed in the U.S.A. ® Bussmann Section Guide Page 1 Electrical – Power Fuses 1 2 Electronic – PC Board and Small Dimension Fuses 29 3 Fuseblocks and Holders 41 4 Disconnect Switches 99 5 High Speed Fuses 123 6 Medium Voltage Fuses and Fuse Links 157 7 Telecommunications Protection 175 8 British, European, & Canadian Standard Industrial Fuses 189 9 Fuse Accessories, Displays, Kits, Etc. 202 10 Fuse Technology 210 Glossary of Terms Index 231 233 Now you can get current information about Bussmann products at anytime, using BIF (Bussmann Information FAX) or visit us on the World Wide Web. Bussmann Information Fax ~ 636.527.1450 Bussmann Worldwide Web ~ BIF is a simple to use automated fax response system. All you need is a touchtone telephone and a fax machine to get complete product specifications when you want it. Data sheet numbers are located throughout this catalog. To get a detailed data sheet on the product of your choice, simply dial 636-527-1450 and request the document number listed. In a matter of minutes a data sheet will be faxed to you. It’s that simple. Data sheets can also be downloaded from the Internet. The Bussmann web site is continuously updated with our newest products and latest data on circuit protection solutions. Visit us often at http://www.bussmann.com http://www.bussmann.com ©2002 Cooper Bussmann Printed in U.S.A. i ® Bussmann Table of Contents Electrical - Power Fuses Disconnect Switches General Data (Selection Guide, Dimensional Data) . . . . . . .1-3 Cubefuse (TCF & TCFH) . . . . . . . . . . . . . . . . . . . . . . . . .4-5 Class L Fuses (KRP-C_SP, KTU, KLU) . . . . . . . . . . . . . . .6-8 Class RK1 Fuses (LPN-RK_SP, LPS-RK_SP, KTN-R, KTS-R) . . . . . .9-11, 15 Class RK5 Fuses (FRN-R, FRS-R, DLN-R, DLS-R) . . . .12-14 One-Time Fuses (NON, NOS) . . . . . . . . . . . . . . . . . . . . . .16 Class J Fuses (LPJ_SP, JKS) . . . . . . . . . . . . . . . . . . . .17-18 Class T Fuses (JJN, JJS) . . . . . . . . . . . . . . . . . . . . . . . . .19 Class G Fuses (SC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Class CC Fuses (LP-CC, FNQ-R, KTK-R) . . . . . . . . . . .21-22 Supplementary Fuses (Midget fuses ⁄‹Ω£™∑ diameter) . . . .23-25 Plug Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-27 Cable Limiters and Welder Limiters . . . . . . . . . . . . . . . . . .28 Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99-105, 121 Non-Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . .106-112 Fusible, Enclosed . . . . . . . . . . . . . . . . . . . . . . . .113-116 Non Fusible, Enclosed . . . . . . . . . . . . . . . . . . . .117-120 Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122 Electronic Fuses PC Board and Small Dimension 5mm x 15mm Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 5mm x 20mm Fuses . . . . . . . . . . . . . . . . . . . . . . . . . .30-31 ⁄Ω¢∑ Diameter Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .32-36 Pin Indicating Type Fuses . . . . . . . . . . . . . . . . . . . . . . .37-38 Actuators and Limiters . . . . . . . . . . . . . . . . . . . . . . . . . . .38 In-Line Fuses/Fuseholders . . . . . . . . . . . . . . . . . . . . . . . .39 Blade-Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Fuseblocks, Holders and Terminal Blocks Overcurrent Protection Modules . . . . . . . . . . . . . . . . . .41-45 Fuse Covers . . . . . . . . . . . . . . . . . . . . . . . . . .46 Fuseblocks Class H, K, and R . . . . . . . . . . . . . . . . . . . . . . .47-52, 63 Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-55, 63 Semiconductor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Class J (Touch Safe) . . . . . . . . . . . . . . . . . . . . . . . .57-58 Class T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59-62 Class CC, G and Type M . . . . . . . . . . . . . . . . . . . . . . .64 for ⁄Ω¢∑ and ⁄‹Ω£™∑ Diameter Fuses . . . . . . . . .66, 83-84, 86 for 5mm Diameter Fuses . . . . . . . . . . . . . . . . . . . . . . .85 Modular Fuseblocks and Fuseholders . . . . . . . . . . . . .65, 67 Box Cover Units for Plug Fuses . . . . . . . . . . . . . . . . . . . . .68 PC Board Mount Fuseholders . . . . . . . . . . . . . . . . . . .69-70 Panel Mount Fuseholders . . . . . . . . . . . . . . . . .71-75, 78-79 In-Line Fuseholders . . . . . . . . . . . . . . . . . . . . .76-77, 80-82 PC Board Fuseclips . . . . . . . . . . . . . . . . . . . . . . . . . . .87-88 Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89-93 Rail Mount Fuseholders . . . . . . . . . . . . . . . . . . . . . . . . . .94 Power Distribution Blocks . . . . . . . . . . . . . . . . . . . . . .95-97 High Speed Fuses North American Style . . . . . . European Style Square Body British Standard BS88 . . . . . Ferrule Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123-130 .131-147 .148-150 .151-158 Medium Voltage Fuses BBU Boric Acid Fuse . . . . . . . . . . . . . . . . . . . . . . . .157-158 R-Rated Fuses (Motor Circuit Protection) . . . . . . . . .161-164 E-Rated Fuses (Transformers Protection) . .159-160, 165-168 DIN Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 Potential Transformer Fuses . . . . . . . . . . . . . . . . . . . . . .170 Medium Volt, Fast Acting . . . . . . . . . . . . . . . . . . . . . . . .171 BS2692-1 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 Fuse Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173 Telecommunications Fused Disconnect Switch Telpower Fuses . . . . . . . . Indicating Fuses & Holders Specialty Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175-181 .182-184 .185-186 .187-188 British, European, & Canadian Standard Industrial Fuses CSA Type P and D Fuses . . . . . . . . . . . . . . . . . . . . . . . .190 HRC Industrial Fuses . . . . . . . . . . . . . . . . . . . . . . . .191-195 BS88 Low Voltage Industrial Fuses . . . . . . . . . . . . . .196-197 DIN Style Type D and Neozed Fuses . . . . . . . . . . . . . . . .198 HRC Fuseholders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199 NH Fuse System . . . . . . . . . . . . . . . . . . . . . . . . . .200-201 Fuse Accessories, Displays, Kits, Etc. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204 Display Racks and Service Kits . . . . . . . . . . . . . . . .205-209 Fuse Technology Fuseology . . . . . . . . . . . . . . . . . . . . . . . Fuse Diagnostic Chart . . . . . . . . . . . . . . Time-Current & Current Limitation Curves Glossary of Terms . . . . . . . . . . . . . . . . . Index ii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210-215 .216-218 .219-230 .231-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233-234 ® General Data — Selection Chart Bussmann Buss Fuse Selection Chart (600 Volts or Less) Circuit Load Ampere Fuse Rating Type Symbol Voltage Rating (a-c) Class Interrupting Rating (KA) Remarks All-purpose fuses. Unequaled for combined short-circuit and overload protection. (Specification grade product) Page Conventional Dimensions—Class RK1, RK5 (0-600A), L (601-6000A) 200,000A or 300,000A Interrupting Rating (rms symmetrical) Current Limiting All type loads (optimum overcurrent protection). Motors, welder, transformers, capacitor banks (circuits with heavy inrush currents). Main, Feeder and Branch LOW-PEAK® (dual-element, time-delay) LPN-RK_SP LPS-RK_SP 250V 600V RK1†† 300 601 to 6000A LOW-PEAK® (time-delay) KRP-C_SP 600V L 300 0 to 600A FUSETRON® (dual-element, time-delay) FRN-R FRS-R 250V 600V RK5†† 200 0 to 600A DURA-LAGTM (dual-element, time-delay) DLN-R DLS-R 250V 600V RK5 200 601 to 4000A LIMITRON® (time-delay) KLU 600V L 200 All-purpose fuse. Timedelay passes surge-currents. 8 KTN-R KTS-R 250V 600V RK1†† 200 Same short-circuit protection as LOW-PEAK fuses but must be sized larger for circuits with surge-currents; i.e., up to 300%. 15 KTU 600V L 200 A fast acting, high performance fuse. 8 Non-motor loads (circuits with no 0 heavy inrush to currents). 600A LIMITRON fuses _____ particularly suited for 601 to circuit breaker 6000A protection. LIMITRON® (fast-acting) Moderate degree of current limitation. Time-delay passes surge currents. 9-11 6-7 12 13 14 Reduced Dimensions For Installation in Restricted Space—Class J(0-600A), T(0-1200A), CC(0-30A), G(0-60A) All type loads (optimum overcurrent protection). __________ Non-motor loads (circuits with no heavy inrush currents). Branch 10,000–50,000 AIC 0-600A General Purpose (noncurrent limiting fuses) 0 to 600A 0 to 1200A LOW-PEAK® (dual-element time-delay) LPJ_SP 600V J 300 All-purpose fuses. Unequaled for combined short-circuit and overload protection. (Specification grade product) 17 LIMITRON® (quick acting) JKS 600V J 200 Very similar to KTS-R LIMITRON, but smaller. 18 T-TRONTM JJN JJS 300V 600V T 200 The space saver (⁄Ω£ the size of KTN-R/KTS-R). 19 Motor loads (circuits with heavy in-rush currents.) 0 to 30A LOW-PEAK® (time-delay) LP-CC 600V CC 200 Rejection feature 21 Non-motor loads (circuits with no heavy in-rush currents.) 0 to 30A LIMITRON® (fast-acting) KTK-R 600V CC 200 Very compact (⁄‹Ω£™∑ ≈ 1⁄Ω™∑); rejection feature. 22 Control transformer circuits and lighting ballasts; etc. 0 to 30A TRON® (time-delay) FNQ-R 600V CC 200 Excellent for control transformer protection. 22 General purpose; i.e., lighting panel boards. 1 to 20A SC SC 600V G 100 Current limiting; ⁄‹Ω£™∑ dia. ≈ varying lengths per amp rating. 20 25 to 60A 480V Miscellaneous 0 to 600A ONE-TIME NON NOS 250V 600V H or K5† 10 Forerunners of the modern 16 Plug fuses can be used for branch circuits and small component protection. 0 to 30A FUSTAT® (dual-element, time-delay) FUSETRON® (dual-element, time-delay) S 125V S 10 26 T 125V ** 10 Buss Type W W Base threads of Type S differ with amp ratings. T and W have Edison base. T & S fuses recommended for motor circuits. W not recommended for circuits with motor loads. 125V ** 10 26 ** UL Listed as Edison Base Plug Fuse. † Some ampere ratings are available as UL Class K5 with a 50,000A interrupting rating. †† RK1 and RK5 fuses fit standard switches, fuseblocks and holders; however, the rejection feature of class R switches and fuseblocks designed specifically for rejection type fuses (RK1 and RK5) prevent the insertion of the non-rejection fuses (K1, K5, and H). 1 ® Bussmann General Data – Dimensions (Inches) CLASS T CLASS J CLASS RK5 & RK1 T-Tron™ Fuses JJN (300V) JJS (600V) Low-Peak® & Limitron® Fuses LPJ & JKS (600V) Fusetron®, Low-Peak® & Limitron® Fuses (250V & 600V) FRN-R & FRS-R; LPN-RK & LPS-RK; KTN-R & KTS-R Basic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and SUPERLAG Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. A B 250V Ampere ⁄Ω¡º-30 35-60 A 2∑ 3∑ 600V B .56∑ .81∑ A 5∑ 5.5∑ B .81∑ 1.06∑ A B Fusetron & Limitron 250V Ampere 70-100 110-200 225-400 450-600 A 5.88∑ 7.13∑ 8.63∑ 10.38∑ B 1.06∑ 1.56∑ 2.06∑ 2.59∑ 600V A 7.88∑ 9.63∑ 11.63∑ 13.38∑ B 1.34∑ 1.84∑ 2.59∑ 3.13∑ Low-Peak 250V Ampere 70-100 110-200 225-400 450-600 A 5.88∑ 7.13∑ 8.63∑ 10.38∑ B 1.16∑ 1.66∑ 2.38∑ 2.88∑ 600V A 7.88∑ 9.63∑ 11.63∑ 13.38∑ B 1.16∑ 1.66∑ 2.38∑ 2.88∑ CLASS L Low-Peak® & Limitron® Fuses KRP-C, KTU, & KLU (601 - 6000A) (600V) NOTE: KRP-CL (150A to 600A) fuses have same dimensions as 601A to 800A case size. KTU (200A to 600A) have same dimensions, except tube 3∑ lgth. ≈ 2∑ dia.; terminal 1fi/•∑ width ≈ 1⁄/¢∑ thick. 2 ® Bussmann General Data – Dimensions (Millimeters) CLASS T CLASS J CLASS RK5 & RK1 T-Tron™ Fuses JJN (300V) JJS (600V) Low-Peak® & Limitron® Fuses LPJ & JKS (600V) Fusetron®, Low-Peak® & Limitron® Fuses (250V & 600V) FRN-R & FRS-R; LPN-RK & LPS-RK; KTN-R & KTS-R Basic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and SUPERLAG Renewable RES & REN fuses. NOTE: These fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility. A B 250V Ampere ⁄Ω¡º-30 35-60 A 50.8 76.2 B 14.3 20.6 600V A 127.0 139.7 B 20.6 27.0 A B Fusetron & Limitron 250V Ampere 70-100 110-200 225-400 450-600 A 149.2 181.0 219.1 263.5 B 26.9 39.6 52.3 65.8 600V A 200.0 244.5 295.3 339.7 B 34.0 46.7 65.8 79.5 Low-Peak 250V Ampere 70-100 110-200 225-400 450-600 A 149.2 181.0 219.1 263.5 B 29.5 42.2 60.5 73.2 600V A 200.0 244.5 295.3 339.7 B 29.5 42.2 60.5 73.2 CLASS L Low-Peak® & Limitron® Fuses KRP-C, KTU, & KLU (601 - 6000A) (600V) NOTE: KRP-CL (150A to 600A) fuses have same dimensions as 601A to 800A case size. KTU (200A to 600A) have same dimensions, except tube 76.2mm lgth. x 50.8mm dia.; terminal 41,3mm width x 31.8mm thick. 3 ® Bussmann Electrical - Power Fuses CUBEFUSE™ and Fuseholder TCF & TCFH Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Catalog Symbol: TCF (Fuse) & TCFH (Holder) Dual-Element, Time-Delay Fuse: 10 Seconds Minimum Operating Time at 500% Rated Current Ampere Rating: 1 to 60A Voltage Rating: 600Vac (or less) DC Voltage Rating: 300 Vdc (or less), 100,000AIR Interrupting Rating: 300,000A RMS Symmetrical (UL) 200,000A RMS Symmetrical (CSA) Agency Information: UL Listed Special Purpose Fuse (UL 248-8) (1-60A) CSA Certified Fuse (CSA-22.2 No. 106) (1-60A) UL Listed Special Purpose Fuseholder CSA Certified Fuseholder (C22.2 Nos. 39 & 65) Other Electrical Certifications: CE compliance for the European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc) Catalog Numbers 1-60 Amps • The world’s first finger safe industrial fuse system. • True dual-element fuse construction with a minimum of 10 seconds time-delay at 500% of rating. • Long time-delay minimizes nuisance circuit openings due to temporary overloads and transient surges. • Meets UL Class J Time-Delay electrical performance requirements. • High interruption rating to safely interrupt faults up to 300,000 amperes. • Faster response to damaging faults reduces destructive thermal and magnetic forces. • Permanent open fuse indication. • Designed to be an internationally accepted and specified world class product. • Smallest footprint of any power class fuse including Class J, CC, T and RK. • Meets requirements of IEC 60529 for IP-20 finger safe rating. • No venting of arc or molten metal and gases during opening. • Robust cycling and inrush current withstand. • Low let through currents under fault conditions. • Provides TYPE 2 “no damage” protection for IEC motors starters when properly sized. • Low watt loss reduces power consumption and lowers operating temperature. • Conventional Class J fuse case sizes and ampere ratings. • Dovetail fuseholder design for ganging multiple fuse poles. • 30 and 60 Amp fuseholders can be ganged together. • 30 Amp fuses can be plugged into the 60A holder without a reducer. • 35mm DIN rail and chassis mounting features. • Fuseholder wire ports rated for dual wires. Carton Quantity and Weight TCF1 TCF3 TCF15 TCF17-1/2 TCF20 TCF25 Ampere Rating TCF1-30 TCF30 TCF35 TCF40 TCF45 TCFH1-30 12 2.42 .902 TCF50 TCF60 TCF35-60 12 1.42 .530 TCFH35-60 12 2.57 .958 TCF6 TCF10 Carton. Qty 12 Weight Per Carton Lbs. Kg. 1.39 .518 CUBEFuse™ Fuseholder Catalog Data Amps 30 60 Poles 1 Wire * #14 - #8 CU Dual Wire * #14 CU Part Number TCFH30 1 #14 - #4 CU #10 CU TCFH60 Time-Current and Current Limitation Curves on page 219. * 75ºC (MIN) CU Wire Only Data Sheet: 9000 4 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann CUBEFUSE™ and Fuseholder Finger-Safe Dual-Element Time-Delay Fuses Indicating – 600 Volts or Less Dimensional Data For TCF and TCFH Dimension 30A in [mm] TCF & TCFH 1-60 Amps Time-Current Characteristic Curves–Average Melt 60A in [mm] A 1.88 [47.75] B .75 [19.05] 2.13 [54.10] 1.00 [25.40] C 1.00 [25.40] 1.13 [28.58] D .31 [7.94] .44 [11.11] E .04 [1.02] .04 [1.02] F .63 [15.88] .63 [15.88] G .27 [6.86] .38 [9.65] H 2.30 [58.42] 2.60 [66.04] I .76 [19.30] 1.03 [26.16] J 1.27 [32.18] 1.53 [38.86] K .15 [3.81] .17 [4.32] For complete specification data, call Bussmann Information Fax ~ 636.527.1450 5 ® Electrical - Power Fuses Bussmann Low-Peak® Time-Delay, Class L Fuses O-RING SEALS Formation of arc gas within fuse body suppresses arcing; lowers arcing I2t energy. O-ring seals maximize pressure build-up during current limiting action. Also volume of sand is critical. Slight loss can adversely impact on current limiting action. O-ring seals insure filler retention. They compensate to a degree for switchgear misalignment, and expansion and contraction of mounting surfaces with change in load to no-load conditions. KRP-C_SP Time-Delay – 4 seconds (minimum) at 500% rated current Ampere Ratings: 601-6000A† Voltage Rating: 600Vac (or less), 300Vdc for 601-2000A. Interrupting Rating: ac: 300,000A RMS Sym. dc: 100,000A Agency Information: UL Listed-Special Purpose (meets all performance requirements of UL Standard 248-10 for Class L fuses), Guide JFHR, File E56412 CSA Certified (200,000 AIR), Class 1422-02, File 53787, Class L per CSA C22.2, No. 248.10 Dimensions: See pages 2-3 for Class L dimensional data. Ordering Information Catalog Number Ctn. Qty. Weight** Lbs. Kg. KRP-C-601SP KRP-C-1900SP 1 3.75 1.7 KRP-C-2001SP KRP-C-800SP KRP-C-2400SP KRP-C-801SP KRP-C-2500SP KRP-C-900SP KRP-C-3000SP 1 4.5 2.041 KRP-C-3800SP KRP-C-1200SP KRP-C-4000SP KRP-C-1350SP KRP-C-4500SP KRP-C-1500SP Kg. 1 8.5 3.85 1 17.25 7.824 1 18.25 8.278 1 23.50 10.659 1 29 13.154 1 36 16.329 KRP-C-3500SP KRP-C-1100SP KRP-C-1400SP Lbs. KRP-C-2000SP KRP-C-750SP KRP-C-1000SP Weight** Ctn. Qty. KRP-C-1800SP KRP-C-650SP KRP-C-700SP Catalog Number 1 6.50 2.948 KRP-C-5000SP KRP-C-6000SP SAND FILLER High grade silica-sand filler. Accelerates response of fuse to short-circuits by having quenching effect upon the fuse arc. Substantially contributes to current limiting action. 99.9% PURE SILVER FUSELINKS Embody “silver-sand” design. 99.9% pure silver links; silicasand filler. The high conductivity of silver gives low watt loss and low operating temperature at normal current levels; minimizes total clearing I2t fault energy let-thru… state-of-art fuse design. High degree of current limitation holds down fault currents and levels of destructive energy. (Although other link materials can provide current limitation, they do not equal that of silver.) • All-purpose silver linked fuse for both overload and shortcircuit protection for high capacity systems (mains and large feeders). • Time-delay (minimum of four seconds at five times amp rating) for close sizing. • Current limiting action of the fuse generally affords considerable reduction in bus bracing. • Interrupting rating of 300,000 amperes complies with NEC Sections 110-9 and 230-65 for today’s large capacity systems. • O-ring seals maximize pressure build-up during current limiting action and ensure filler retention. • High grade silica-sand filler; accelerates response of fuse to short-circuits by having quenching effect upon the fuse arc. • 99.9% pure silver fuselinks. The high conductivity of silver gives low watt loss and low operating temperature at normal current levels; minimizes total clearing I 2t fault energy let-thru. • Selective coordination (blackout prevention) • Glass melamine tube. • Silver plated end bells. • Reducers not necessary. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. KRP-C-1600SP Special purpose rating of 300,000 AIR. **Weight per carton. †Use KRP-CL for current ratings below 601A. Data Sheet: 1008 and 1009 6 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann 4000A 5000A 6000A 1600A 2000A 2500A 3000A 1200A 800A Time-Current Characteristic Curves—Average Melt KRP-C Current Limitation Curves—KRP-C 1000,000 B AMPERE RATING AMPERE RATING A 1,000 300,000 1 10,000 100,000 TIME IN SECONDS 10 100,000 10,000 100 6,000A 5,000A 4,000A 3,000A 2,500A 2,000A 1,600A 1,200A 800A 601A 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 300 PROSPECTIVE SHORT CIRCUIT CURRENT SYMMETRICAL RMS AMPERES Recommended Fuseblocks for Class L: (601–1200A) .1 Catalog Number Poles 51215 1 51235 3 200,000 100,000 1,000 .01 CURRENT IN AMPERES 10,000 Use KRP-CL for current ratings below 601A. KRP-CL Dimensions: See pages 2-3 for Class L dimensional data. Current Limiting, Time-Delay Construction: Glass Melamine Tube Ampere Ratings: 150-600A. Voltage Rating: 600Vac (or less) These fuses have the same performance characteristics as KRP-C fuses. They are used in applications where there is a need for Class L dimension fuses with 150-600A ratings. KRP-CL fuses have the same dimensions as 800A Class L fuses. Ordering Information Catalog Number (Symbol & Amps) KRP-CL-150 KRP-CL-300 KRP-CL-500 KRP-CL-200 KRP-CL-350 KRP-CL-600 KRP-CL-225 KRP-CL-400 KRP-CL-250 KRP-CL-450 Weight of each is 3.75 lbs. Data Sheet: 1016 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 7 ® Electrical - Power Fuses Bussmann Limitron® Class L Fuses KTU KLU Fast Acting, Bolt Mount Ampere Ratings: 601-6000A. Voltage Rating: 600Vac (or less) Interrupting Rating: 200,000 RMS Sym. Agency Information: Std. 248-10, Class L UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class L dimensional data. Time-Delay – 5 seconds (minimum) at 500% rated current Bolt Mount Ampere Ratings: 601-4000A. Voltage Rating: 600Vac (or less) Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-10, Class L UL Listed, Guide JDDZ, File E4273 CSA Certified, CSA Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class L dimensional data. Ordering Information Catalog Number Ctn. Qty. Weight** Lbs. Kg. Catalog Number KTU-601 KTU-1800 KTU-650 KTU-2000 KTU-700 1 3.75 1.70 KTU-2400 KTU-750 KTU-2500 KTU-800 KTU-3000 KTU-801 KTU-3001 KTU-900 KTU-4000 KTU-1100 1 4.25 1.927 KTU-4500 KTU-1200 KTU-5000 KTU-1350 KTU-6000 KTU-1400 KTU-1500 1 6 Weight** Ctn. Qty. Lbs. Kg. 1 8.5 3.855 1 17 7.711 1 17.25 7.824 1 24 10.886 1 31 14.061 1 34 15.422 Recommended Fuseblocks for Class L: (601–1200A) 1 3 Kg. KLU-700 KLU-1000 KLU-1500 KLU-1600 Catalog Number Weight** Ctn. Qty. Lbs. Kg. 1 8.50 3.86 KLU-1800 KLU-2000 1 3.75 1.70 KLU-2500 KLU-3000 1 4.25 1.93 1 6.00 2.72 KLU-4000 **Weight per carton. • For protection of circuit breakers with lower interrupting ratings and non-inductive loads such as lighting and heating circuits. • 99.9% pure silver-links. • Reducers not necessary. 51235 Weight** Lbs. KLU-650 KLU-1200 **Weight per carton. 51215 Ctn. Qty. KLU-800 KTU-1600 Poles Catalog Number KLU-601 2.721 Catalog Number Ordering Information • KLU Limitron® general purpose copper link fuses. • Current limiting—provides component short-circuit protection. • Fuse reducers not necessary. • See KRP-CL for current ratings below 601A Recommended Fuseblocks: (601–1200A) Catalog Number Poles 51215 1 51235 3 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1010 8 Data Sheet: 1013 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Low-Peak® Dual-Element, Time-Delay, Class RK1 Fuses LPN-RK_SP (250V) LPS-RK_SP (600V) Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current (8 seconds for 0-30A sizes) Ampere Ratings: ⁄Ω¡º-600A. Voltage Rating: LPN-RK: 250Vac (or less), 125Vdc (⁄Ω¡º-60A); 250Vdc (70-600 A) LPS-RK: 600Vac (or less), 300Vdc Current Limiting RK1 Fuse Interrupting Rating: ac: 300,000A RMS Sym. dc: 100,000A Agency Information: UL Listed – Special Purpose**, Guide JFHR, File E56412 CSA Certified (200,000 AIR), Class RK1 per CSA C22.2, No. 248.12, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class RK1 dimensional data. Catalog Numbers (250Vac/125Vdc) • Current limitation for maximum short-circuit protection. High speed of response is highly sensitive to fault currents, but insensitive to starting current and transient surges. • Provides long time-delay for temporary motor start-up. • Time-delay permits 125% FLA sizing for back-up, motor running protection. Catalog Numbers (600Vac/300Vdc) LPS-RK-⁄Ω¡ºSP LPS-RK-2⁄Ω™SP LPS-RK-12SP LPS-RK-¤Ω¡ºSP LPS-RK-2°Ω¡ºSP LPS-RK-15SP LPS-RK-125SP LPS-RK-‹Ω¡ºSP LPS-RK-3SP LPS-RK-17⁄Ω™SP LPS-RK-150SP LPS-RK-›Ω¡ºSP LPS-RK-3¤Ω¡ºSP LPS-RK-20SP LPS-RK-175SP LPS-RK-⁄Ω™SP LPS-RK-3⁄Ω™SP LPS-RK-25SP LPS-RK-200SP LPS-RK-flΩ¡ºSP LPS-RK-4SP LPS-RK-30SP LPS-RK-225SP LPS-RK-°Ω¡ºSP LPS-RK-4⁄Ω™SP LPS-RK-35SP LPS-RK-250SP LPS-RK-1SP LPS-RK-5SP LPS-RK-40SP LPS-RK-300SP LPS-RK-1⁄Ω•SP LPS-RK-5flΩ¡ºSP LPS-RK-45SP LPS-RK-350SP LPS-RK-1⁄Ω¢SP LPS-RK-6SP LPS-RK-50SP LPS-RK-400SP LPS-RK-1›Ω¡ºSP LPS-RK-6⁄Ω¢SP LPS-RK-60SP LPS-RK-450SP LPS-RK-1⁄Ω™SP LPS-RK-7SP LPS-RK-70SP LPS-RK-500SP LPS-RK-1flΩ¡ºSP LPS-RK-8SP LPS-RK-80SP LPS-RK-600SP LPS-RK-1°Ω¡ºSP LPS-RK-9SP LPS-RK-90SP LPS-RK-2⁄Ω¢SP LPS-RK-10SP LPS-RK-100SP LPN-RK-⁄Ω¡ºSP LPN-RK-3⁄Ω™SP LPN-RK-60SP LPN-RK-⁄fiΩ¡ººSP LPN-RK-4SP LPN-RK-70SP LPN-RK-¤Ω¡ºSP LPN-RK-4⁄Ω™SP LPN-RK-80SP LPN-RK-‹Ω¡ºSP LPN-RK-5SP LPN-RK-90SP LPN-RK-›Ω¡ºSP LPN-RK-5flΩ¡ºSP LPN-RK-100SP LPN-RK-⁄Ω™SP LPN-RK-6SP LPN-RK-110SP Carton Quantity and Weight LPN-RK-flΩ¡ºSP LPN-RK-6⁄Ω¢SP LPN-RK-125SP LPN-RK (250Vac) LPS-RK-110SP **Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses. LPN-RK-°Ω¡ºSP LPN-RK-8SP LPN-RK-150SP LPN-RK-1SP LPN-RK-9SP LPN-RK-175SP LPN-RK-1⁄Ω•SP LPN-RK-10SP LPN-RK-200SP 0-30 10 LPN-RK-1⁄Ω¢SP LPN-RK-12SP LPN-RK-225SP 35-60 Ampere Ratings Carton Qty. LPS-RK (600Vac) Weight* Weight* Kg Carton Qty. Lbs. Kg 0.5 0.227 10 1.6 0.725 10 1.2 0.544 10 2.6 1.178 5 1.5 0.680 5 4.0 1.814 Lbs. LPN-RK-1›Ω¡ºSP LPN-RK-15SP LPN-RK-250SP 70-100 LPN-RK-1flΩ¡ºSP LPN-RK-17⁄Ω™SP LPN-RK-300SP 110-200 1 0.69 0.313 1 2.0 0.906 LPN-RK-1°Ω¡ºSP LPN-RK-20SP LPN-RK-350SP 225-400 1 1.75 0.793 1 4.6 2.086 LPN-RK-400SP 450-600 1 3.25 1.474 1 5.6 2.540 LPN-RK-2SP LPN-RK-25SP LPN-RK-2⁄Ω¢SP LPN-RK-30SP LPN-RK-450SP LPN-RK-2⁄Ω™SP LPN-RK-35SP LPN-RK-500SP LPN-RK-2°Ω¡ºSP LPN-RK-40SP LPN-RK-600SP LPN-RK-3SP LPN-RK-45SP LPN-RK-3¤Ω¡ºSP LPN-RK-50SP *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. **Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses. 0-60A fuses available with Nickel plate option. (Ex: LPSRK30SPNP) 70-600A fuses available with Tin plate option. (Ex: LPS-RK-100SP-TP) Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600) Data Sheet: (LPS-RK) 1001 (0-60) & 1002 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 9 ® Electrical - Power Fuses Bussmann Low-Peak® Dual-Element, Time-Delay, Class RK1 Fuses Time-Current Characteristic Curves—Average Melt 60 100 200 400 600 AMPERE RATING 10 10 60 100 200 400 600 AMPERE RATING .01 .01 61/4 10 2 32/10 / 11/4 2 10 / / / 1 16/10 21/2 4 5 8 12 AMPERE RATING 8 10 / / / / 1 10 15 100 4 5 8 10 12 AMPERE RATING 1 2 6 10 CURRENT IN AMPERES 6 1 /4 2 1 /2 32/10 8/10 1 1 /4 2 16/10 1 6/10 3/10 4/10 2/10 1 /2 15/100 20 100 20 10,000 .1 1,000 .1 10,000 1 1,000 1 100 TIME IN SECONDS 100 TIME IN SECONDS 100 1/10 30 300 CURRENT IN AMPERES 300 20 3 10 4 10 300 15 20 30 LPN-RK 250V LPS-RK 600V 100 TIME IN SECONDS TIME IN SECONDS 10 1 CURRENT IN AMPERES RMS SYMMETRICAL CURRENT IN AMPERES Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600) 10 1,000 100 10 .1 .01 1 .1 CURRENT IN AMPERES Data Sheet: (LPS-RK) 1001 (0-60) & 1002 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Low-Peak® Dual-Element, Time-Delay, Class RK1 Fuses Current Limitation Curves—LPN-RK (250V) B AMPERE RATING 400,000 100,000 600 400 200 100 60 10,000 30 200,000 100,000 1,000 10,000 A 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Recommended fuseblocks for Class R 250 & 600V fuses See pages 47-52 RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) B AMPERE RATING 400,000 100,000 600 400 200 100 60 10,000 30 200,000 10,000 1,000 100,000 A 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Current Limitation Curves—LPS-RK (600V) RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600) Data Sheet: (LPS-RK) 1001 (0-60) & 1002 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 11 ® Electrical - Power Fuses Bussmann Fusetron® Dual-Element, Time-Delay, Class RK5 Fuses • Provides motor overload, ground fault and short-circuit protection when sized properly. • Helps protect motors against burnout from overloads when sized properly. • Helps protect motors against burnout from single phasing on three phase systems when sized properly. • Simplifies and improves blackout prevention (selective coordination) when sized properly. Fuse Reducers For Class R Fuses Equipment Fuse Clips FRN-R (250V) Desired Fuse (Case) Size 60A Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: ⁄Ω¡º-600A. Voltage Rating: 250Vac (or less), 125Vdc Current Limiting RK5 Fuse Interrupting Rating: 200,000A RMS Sym. (20,000A @ 125Vdc) Agency Information: Std. 248-12, Class RK5 UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-01, File 53787 Dimensions: See pages 2-3 for Class RK5 dimensional data. Catalog Numbers (250Vac/125Vdc) FRN-R-⁄Ω¡º FRN-R-2 FRN-R-10 FRN-R-100 FRN-R-⁄Ω• FRN-R-2⁄Ω¢ FRN-R-12 FRN-R-110 FRN-R-⁄fiΩ¡ºº FRN-R-2⁄Ω™ FRN-R-15 FRN-R-125 FRN-R-¤Ω¡º FRN-R-2°Ω¡º FRN-R-17⁄Ω™ FRN-R-150 FRN-R-⁄Ω¢ FRN-R-3 FRN-R-20 FRN-R-175 FRN-R-‹Ω¡º FRN-R-3¤Ω¡º FRN-R-25 FRN-R-200 FRN-R-›Ω¡º FRN-R-3⁄Ω™ FRN-R-30 FRN-R-225 FRN-R-⁄Ω™ FRN-R-4 FRN-R-35 FRN-R-250 FRN-R-flΩ¡º FRN-R-4⁄Ω™ FRN-R-40 FRN-R-300 FRN-R-°Ω¡º FRN-R-5 FRN-R-45 FRN-R-350 FRN-R-1 FRN-R-5flΩ¡º FRN-R-50 FRN-R-400 FRN-R-1⁄Ω• FRN-R-6 FRN-R-60 FRN-R-450 FRN-R-1⁄Ω¢ FRN-R-6⁄Ω¢ FRN-R-70 FRN-R-500 FRN-R-1›Ω¡º FRN-R-7 FRN-R-75 FRN-R-600 FRN-R-1⁄Ω™ FRN-R-7⁄Ω™ FRN-R-80 FRN-R-1flΩ¡º FRN-R-8 FRN-R-85 FRN-R-1°Ω¡º FRN-R-9 FRN-R-90 100A 200A 400A 600A Catalog Number (Pairs) 250V 30A No. 263-R 30A No. 213-R 60A No. 216-R 60A No. 226-R 100A No. 2621-R 100A No. 2641-R 200A No. 242-R 100A No. 2661-R 200A No. 2662-R 400A No. 2664-R* *Single reducer only (pair not required). Time-Current and Current Limitation Curves located on page 223. Recommended fuseblocks for Class R 250V fuses See pages 47-49 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Carton Quantity and Weight Ampere Ratings Weight* Carton Qty. Lbs. Kg. 0-15 10 0.40 0.181 17.5-30 10 .50 0.227 35-60 10 1.00 0.453 70-100 5 1.5 0.680 101-200 1 0.77 0.349 201-400 1 1.52 0.689 401-600 1 2.94 1.334 *Weight per carton. Data Sheet: 1019 (0-60), 1020 (70-600) 12 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Fusetron® Dual-Element, Time-Delay, Class RK5 Fuses FRS-R (600V) Fuse Reducers For Class R Fuses Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: ⁄Ω¡º-600A. Voltage Rating: 600Vac (or less), 300Vdc Current Limiting RK5 Fuse Interrupting Rating: 200,000A RMS Sym. (20,000A @ 300Vdc) Agency Information: Std. 248-12, Class RK5 UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class RK5 dimensional data. Catalog Numbers (600Vac/ 300Vdc) Equipment Fuse Clips Desired Fuse (Case) Size 60A 100A 200A 400A 600A Catalog Number (Pairs) 600V 30A No. 663-R 30A No. 216-R 60A No. 616-R 60A No. 626-R 100A No. 2621-R 100A No. 2641-R 200A No. 642-R 100A No. 2661-R 200A No. 2662-R 400A No. 2664-R* *Single reducer only (pair not required). FRS-R-⁄Ω¡º FRS-R-2 FRS-R-10 FRS-R-110 FRS-R-⁄Ω• FRS-R-2⁄Ω¢ FRS-R-12 FRS-R-125 FRS-R-⁄fiΩ¡ºº FRS-R-2⁄Ω™ FRS-R-15 FRS-R-150 FRS-R-¤Ω¡º FRS-R-2°Ω¡º FRS-R-17⁄Ω™ FRS-R-175 FRS-R-⁄Ω¢ FRS-R-3 FRS-R-20 FRS-R-200 FRS-R-‹Ω¡º FRS-R-3¤Ω¡º FRS-R-25 FRS-R-225 FRS-R-›Ω¡º FRS-R-3⁄Ω™ FRS-R-30 FRS-R-250 FRS-R-⁄Ω™ FRS-R-4 FRS-R-35 FRS-R-275 FRS-R-flΩ¡º FRS-R-4⁄Ω™ FRS-R-40 FRS-R-300 FRS-R-°Ω¡º FRS-R-5 FRS-R-45 FRS-R-325 FRS-R-1 FRS-R-5flΩ¡º FRS-R-50 FRS-R-350 FRS-R-1⁄Ω• FRS-R-6 FRS-R-60 FRS-R-400 FRS-R-1⁄Ω¢ FRS-R-6⁄Ω¢ FRS-R-70 FRS-R-450 FRS-R-1›Ω¡º FRS-R-7 FRS-R-75 FRS-R-500 FRS-R-1⁄Ω™ FRS-R-7⁄Ω™ FRS-R-80 FRS-R-600 FRS-R-1flΩ¡º FRS-R-8 FRS-R-90 FRS-R-1°Ω¡º FRS-R-9 FRS-R-100 Time-Current and Current Limitation Curves located on page 224. Recommended fuseblocks for Class R 600V fuses See pages 50-52 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Carton Quantity and Weight Ampere Ratings 0-15 Weight* Carton Qty. Lbs. Kg. 10 0.40 0.181 0.227 17.5-30 10 0.50 35-60 10 3.10 1.406 65-100 1 0.54 0.245 101-200 1 1.22 0.544 201-400 1 3.00 1.359 401-600 1 5.00 2.268 *Weight per carton. Data Sheet: 1017 (0-60), 1018 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 13 ® Electrical - Power Fuses Bussmann Dura-Lag™ Dual-Element, Time-Delay, Class RK5 Fuses DLN-R (250V) DLS-R (600V) Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: 1-600A Voltage Rating: 250Vac (or less), 125Vdc Current Limiting RK5 Fuses Interrupting Rating: 200,000A RMS Sym. (20,000A @125Vdc) Agency Information: Std. 248-12, Class RK5 UL Listed, Guide JDDZ, File E4273 CSA C22.2, No. 106-HRCI-R, File 53787 Dimensions: See pages 2-3 for Class RK5 dimensional data. Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Ampere Ratings: 1-600A Voltage Rating: 600Vac (or less), 300Vdc Current Limiting RK5 Fuses Interrupting Rating: 200,000A RMS Sym., (20,000A @ 300Vdc) Agency Information: Std. 248-12, Class RK5 UL Listed, Guide JDDZ, File E4273 CSA C22.2, No. 106-HRCI-R Dimensions: See pages 2-3 for Class RK5 dimensional data. Catalog Numbers (250Vac/125Vdc) Catalog Numbers (600Vac/300Vdc) DLN-R-1 DLN-R-2 DLN-R-2⁄Ω™ DLN-R-3 DLN-R-3¤Ω¡º DLN-R-4 DLN-R-5 DLN-R-6 DLN-R-6⁄Ω¢ DLN-R-8 DLN-R-10 DLN-R-12 DLN-R-15 DLN-R-20 DLN-R-25 DLN-R-30 DLN-R-35 DLN-R-40 DLN-R-45 DLN-R-50 DLN-R-60 DLN-R-70 DLN-R-80 DLN-R-90 DLN-R-100 DLN-R-125 DLN-R-150 DLN-R-175 DLN-R-200 DLN-R-225 DLN-R-250 DLN-R-300 DLN-R-400 DLN-R-600 Carton Quantity and Weight Ampere Ratings ⁄Ω¡º-30 35-60 Weight* Carton Qty. Lbs. Kg. 10 0.56 0.252 10 1.38 0.621 70-100 5 1.56 0.702 110-200 1 0.90 0.405 225-400 450-600 1 1 1.80 3.30 0.810 1.485 *Weight per carton. Recommended fuseblocks for Class R 250V fuses See pages 47-49 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1021 (0-600) 14 DLS-R-1 DLS-R-1flΩ¡º DLS-R-2 DLS-R-2⁄Ω™ DLS-R-3 DLS-R-3⁄Ω™ DLS-R-4 DLS-R-5 DLS-R-6 DLS-R-6⁄Ω¢ DLS-R-7 DLS-R-8 DLS-R-9 DLS-R-10 DLS-R-12 DLS-R-15 DLS-R-17⁄Ω™ DLS-R-20 DLS-R-25 DLS-R-30 DLS-R-35 DLS-R-40 DLS-R-45 DLS-R-50 DLS-R-60 DLS-R-70 DLS-R-80 DLS-R-90 DLS-R-100 DLS-R-110 DLS-R-125 DLS-R-150 DLS-R-175 DLS-R-200 DLS-R-225 DLS-R-250 DLS-R-300 DLS-R-350 DLS-R-400 DLS-R-500 DLS-R-600 Carton Quantity and Weight Ampere Ratings Weight* Carton Qty. Lbs. Kg. ⁄Ω¡º-30 10 1.62 0.729 35-60 10 3.00 1.35 70-100 5 3.00 1.35 110-200 1 1.41 0.635 225-400 1 3.13 1.409 450-600 1 5.28 2.376 *Weight per carton. Recommended fuseblocks for Class R 600V fuses See pages 50-52 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1022 (0-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Limitron® Fast Acting, Class RK1 Fuses KTN-R (250V) KTS-R (600V) Fast Acting Ampere Ratings: 1-600A Voltage Rating: 250Vac (or less). Current Limiting RK1 Fuse (curves on page 205) Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-12, Class RK1 UL Listed, Guide JDDZ, File E54273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class RK1 dimensional data. Fast Acting Ampere Ratings: 1-600A Voltage Rating: 600Vac (or less). Current Limiting RK1 Fuse (curves on page 206) Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-12, Class RK1 UL Listed, Guide JDDZ, File E54273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class RK1 dimensional data. Catalog Numbers (250Vac) Catalog Numbers (600Vac) KTN-R-1 KTN-R-2 KTN-R-3 KTN-R-4 KTN-R-5 KTN-R-6 KTN-R-8 KTN-R-10 KTN-R-12 KTN-R-15 KTN-R-20 KTN-R-25 KTN-R-30 KTN-R-35 KTN-R-40 KTN-R-45 KTN-R-50 KTN-R-60 KTN-R-70 KTN-R-75 KTN-R-80 KTN-R-90 KTN-R-100 KTN-R-110 KTN-R-125 KTN-R-150 KTN-R-175 KTN-R-200 KTN-R-225 KTN-R-250 KTN-R-300 KTN-R-350 KTN-R-400 KTN-R-450 KTN-R-500 KTN-R-600 Carton Quantity and Weight KTS-R-1 KTS-R-2 KTS-R-3 KTS-R-4 KTS-R-5 KTS-R-6 KTS-R-8 KTS-R-10 KTS-R-12 KTS-R-15 KTS-R-20 KTS-R-25 KTS-R-30 KTS-R-35 KTS-R-40 KTS-R-45 KTS-R-50 KTS-R-60 KTS-R-70 KTS-R-75 KTS-R-80 KTS-R-90 KTS-R-100 KTS-R-110 KTS-R-125 KTS-R-150 KTS-R-175 KTS-R-200 KTS-R-225 KTS-R-250 KTS-R-300 KTS-R-350 KTS-R-400 KTS-R-450 KTS-R-500 KTS-R-600 Carton Quantity and Weight Weight* Weight* Ampere Ratings Carton Qty. Lbs. Kg. Ampere Ratings Carton Qty. Lbs. Kg. 1-30 40-60 70-100 110-200 225-400 450-600 10 10 5 1 1 1 .45 1.82 1.85 1.05 2.38 3.50 0.204 0.824 0.838 0.476 1.078 1.587 1-30 40-60 70-100 110-200 225-400 450-600 10 10 1 1 1 1 1.45 2.63 0.5 1.4 2.75 4.25 0.657 1.262 0.226 0.634 1.246 1.925 *Weight per carton. *Weight per carton. Time-Current and Current Limitation Curves located on page 225. Time-Current and Current Limitation Curves located on page 226. Recommended fuseblocks for Class R 250V fuses See pages 47-49 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Recommended fuseblocks for Class R 600V fuses See pages 50-52 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1043 (0-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 1044 (0-600) 15 ® Electrical - Power Fuses Bussmann One-Time General Purpose Fuses NON and NOS General Purpose Application Non-Current Limiting Ampere Ratings: ⁄Ω•-600A Voltage Rating: NON: 250Vac, 125Vdc (0-100A); NOS: 600Vac Interrupting Rating: 50,000A RMS Sym. (0-60A), 10,000A RMS Sym. (65-600A), 50,000A @ 125Vdc (NON 0-60), 10,000A @ 125Vdc (NON 65-100A) Agency Information: UL Listed – 250V: Class K5 (0-60A), Std. 248-9 Class H (65-600A), Std. 248-6 (125Vdc: NON 0-100) 600V: Class K5 (0-60A), Std. 248-9 Class H (70-600A), Std. 248-6 Guide JDDZ, File E4273 CSA Certified – 250V: (0-12, 65-600)† 600V: (0-600) Class 1421-01, File 53787 Dimensions: See pages 2-3 for dimensional data under Class RK5/RK1. † For CSA Certified 15-60A Ratings, see PON Data Sheet 4126 Catalog Numbers (250Vac) NON-⁄Ω• NON-⁄Ω™ NON-‹Ω¢ NON-°Ω¡º NON-1 NON-1⁄Ω¢ NON-1⁄Ω™ NON-1flΩ¡º NON-2 NON-2⁄Ω™ NON-3 NON-3¤Ω¡º NON-4 NON-5 NON-6 NON-6⁄Ω¢ NON-7 NON-8 NON-9 NON-10 NON-12 NON-15 NON-20 NON-25 NON-30 NON-35 NON-40 NON-45 NON-50 NON-60 NON-65 NON-70 NON-75 NON-80 NON-90 NON-100 NON-110 NON-125 NON-150 NON-175 NON-200 NON-225 NON-250 NON-300 NON-350 NON-400 NON-450 NON-500 NON-600 — — — Recommended Fuse Reducers 250V 600V Cat. Clip Fuse No. Size Size (Pair) 60A 30A No. 263 100A 30A No. 213 100A 60A No. 216 200A 60A No. 226 200A 100A No. 2621 400A 100 No. 2641 400A 200A No. 2642 600A 100A No. 2661 600A 200A No. 2662 600A 400A No. 2664 *Carton quantity—10 pair. Weight Carton* (lbs) 0.38 1.73 1.73 3.00 1.63 4.90 3.50 8.70 6.85 4.45 Clip Size 60A 100A 100A 200A 200A 400A 400A 600A 600A 600A Fuse Size 30A 30A 60A 60A 100A 100 200A 100A 200A 400A Cat. No. (Pair) No. 663 No. 216 No. 616 No. 626 No. 2621 No. 2641 No. 2642 No. 2661 No. 2662 No. 2664 Weight Carton* (lbs) 1.00 1.73 1.85 3.33 1.63 4.90 3.50 8.70 6.85 4.45 Catalog Numbers (600Vac) NOS-1 NOS-2 NOS-3 NOS-4 NOS-5 NOS-6 NOS-7 NOS-8 NOS-9 NOS-10 NOS-12 NOS-15 NOS-20 NOS-25 NOS-30 NOS-35 NOS-40 NOS-45 NOS-50 NOS-60 NOS-70 NOS-75 NOS-80 NOS-90 NOS-100 NOS-110 NOS-125 NOS-150 NOS-175 — NOS-200 NOS-225 NOS-250 NOS-300 NOS-350 NOS-400 NOS-450 NOS-500 NOS-600 — Carton Quantity and Weight Carton Quantity and Weight Ampere Ratings NON NON NON NON NON NON Ampere Ratings Weight* Carton Qty. Lbs. Kg. 10 10 5 1 1 1 0.38 1.00 0.79 0.79 1.65 2.76 0.172 0.453 0.358 0.358 0.748 1.25 ⁄Ω•-30 35-60 65-100 110-200 225-400 450-600 NOS NOS NOS NOS NOS NOS 1-30 35-60 70-100 110-200 225-400 450-600 Weight* Carton Qty. Lbs. Kg. 10 10 5 1 1 1 1.45 2.6 2.80 1.24 3.03 4.63 0.657 1.179 1.270 0.562 1.374 2.100 *Weight per carton. *Weight per carton. Catalog Symbol & Current Ratings Symbol NON NOS Rating 0-60 65-600 0-60 65-100 0-60 70-600 Class K5 H K5 H K5 H Volt 250ac 250ac 125dc 125dc 600 600 IR 50,000 10,000 50,000 10,000 50,000 10,000 Recommended fuseblocks for Class H (K) 250 & 600V fuses See pages 47-52 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1030 16 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Low-Peak® Dual-Element, Time-Delay, Class J Fuses LPJ_SP 600A 400A 125A 200A 250A 60A 80A 100A 30A 15A 10A 6A 3A AMPERE RATING TIME IN SECONDS 1A Time-Current Classification Curves—Average Melt Dual-Element, Time-Delay – 300 10 seconds (minimum) at 200 500% rated current 100 Ampere Ratings: 1-600A Voltage Rating: 600Vac (or less), 300Vdc (or less) 10 Current Limiting Interrupting Rating: ac – 300,000A RMS Sym. dc – 100,000A Agency Information: UL Listed - Special Purpose**, Guide JFHR, File E56412 1 CSA Certified (200,000 AIR) Class J per CSA-22.2 No. 248.8, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class J dimensional data. Catalog Numbers LPJ-200SP LPJ-2SP LPJ-7SP LPJ-45SP LPJ-225SP LPJ-2⁄Ω¢SP LPJ-8SP LPJ-50SP LPJ-250SP LPJ-2⁄Ω™SP LPJ-9SP LPJ-60SP LPJ-300SP LPJ-2°Ω¡ºSP LPJ-10SP LPJ-70SP LPJ-350SP LPJ-3SP LPJ-12SP LPJ-80SP LPJ-400SP .01 CURRENT IN AMPERES Current Limitation Curves LPJ-15SP LPJ-90SP LPJ-450SP LPJ-3⁄Ω™SP LPJ-17⁄Ω™SP LPJ-100SP LPJ-500SP LPJ Current Limitation Curves LPJ-4SP LPJ-20SP LPJ-110SP LPJ-600SP 100,000 Lbs. Kg. 10 1.09 0.49 35-60 10 1.78 0.81 70-100 5 1.69 0.77 110-200 5 4.21 1.91 225-400 1 1.67 0.76 450-600 1 2.80 0.27 *Weight per carton. Recommended fuseblocks/fuseholders for Class J 600V fuses • Open fuseblocks - see pages 53-55 • Finger-safe fuseholders for 30A & 60Asee pages 57-58 • Modular fuseblocks - see page 67 200A 100A 60A 10,000 30A 15A AMPERE RATING 0-30 Weight* Carton Qty. 1,000 A 100 1,000 Ampere Ratings B 600A 400A 100 Carton Quantity and Weight INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS LPJ-3¤Ω¡ºSP **Meets all performance requirements of UL Standard 248-8 for Class J fuses. Available with silver plated terminals. Add SP/ in front of part number. 10,000 LPJ-175SP LPJ-40SP 200,000 LPJ-35SP LPJ-6SP 300,000 LPJ-5flΩ¡ºSP LPJ-1°Ω¡ºSP 100,000 LPJ-1flΩ¡ºSP .1 1,000 LPJ-150SP 10,000 LPJ-125SP LPJ-30SP 100 LPJ-25SP LPJ-5SP 10 LPJ-4⁄Ω™SP LPJ-1⁄Ω¢SP 1 LPJ-1SP PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPS CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1006 (0-60) and 1007 (70-600) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 17 ® Electrical - Power Fuses Bussmann Limitron® Quick Acting, Class J Fuses JKS Recommended fuseblocks/fuseholders for Class J 600V fuses • Open fuseblocks - see pages 53-55 • Finger-safe fuseholders for 30A & 60Asee pages 57-58 • Modular fuseblocks - see page 67 Quick Acting Ampere Ratings: 1-600A Voltage Rating: 600Vac (or less) Current Limiting Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-8, Class J UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class J dimensional data. Catalog Numbers JKS-1 JKS-15 JKS-70 JKS-225 JKS-2 JKS-20 JKS-80 JKS-250 JKS-3 JKS-25 JKS-90 JKS-300 JKS-4 JKS-30 JKS-100 JKS-5 JKS-35 JKS-110 JKS-6 JKS-40 JKS-125 JKS-8 JKS-45 JKS-10 JKS-50 JKS-12 JKS-60 JKS-200 Fuse Reducers for J Dimension Fuses JKS-350 Clip Size 60A Fuse Size 30A Cat. No. (Pair) J63 Weight Carton* (lbs) 0.38 Clip Size 400A Fuse Size 100A Cat. No. (Pair) J41 JKS-400 100A 30A J13 1.73 400A 200A J42 2.75 JKS-450 100A 60A J16 1.85 600A 400A J64 3.55 JKS-150 JKS-500 200A 60A J26 2.55 600A 200A J62 3.55 JKS-175 JKS-600 200A 100A J21 1.36 — — — *Carton quantity—10 pair. Carton Quantity and Weight Ampere Ratings 1-30 35-60 70-100 110-200 225-400 450-600 Carton Qty. 10 10 5 1 1 1 Weight* Lbs. 0.95 1.175 0.28 0.86 1.78 3.07 Kg. 0.43 0.53 0.13 0.39 0.81 1.39 *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1026 (1-60A), 1027 (70-600A) 18 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Weight Carton* (lbs) 4.90 — ® Electrical - Power Fuses Bussmann T-Tron® Very Fast Acting, Class T Fuses JJN JJS Very Fast Acting Ampere Ratings: 1-1200A Voltage Rating: 300Vac (or less), (15-600A 160Vdc; 601-1200 170Vdc) Current Limiting (curves on page 208) Interrupting Rating: 200,000A RMS Sym. (20,000A dc @ 160Vdc & 100,000A dc @ 170Vdc) Agency Information: Std. 248-15, Class T UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class T dimensional data. Very Fast Acting Ampere Ratings: 1-800A Voltage Rating: 600Vac (or less) Current Limiting (curves on page 208) Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 24815, Class T UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-02, File 53787 Dimensions: See pages 2-3 for Class T dimensional data. Catalog Numbers Catalog Numbers JJN-1 JJN-2 JJN-3 JJN-6 JJN-10 JJN-15 JJN-20 JJN-25 JJN-30 JJN-35 JJN-40 JJN-45 JJN-50 JJN-60 JJN-70 JJN-80 JJN-90 JJN-100 JJN-110 JJN-125 JJN-150 JJN-175 JJN-200 JJN-225 JJN-250 JJN-300 JJN-350 JJN-400 JJN-450 JJN-500 JJN-600 JJN-700 JJN-800 JJN-1000 JJN-1200 JJS-1 JJS-2 JJS-3 JJS-6 JJS-10 JJS-15 JJS-20 JJS-25 JJS-30 JJS-35 JJS-40 JJS-45 JJS-50 JJS-60 JJS-70 JJS-80 JJS-90 JJS-100 JJS-110 JJS-125 JJS-150 JJS-175 JJS-200 JJS-225 JJS-250 JJS-300 JJS-350 JJS-400 JJS-450 JJS-500 JJS-600 JJS-800 Carton Quantity and Weight Carton Quantity and Weight Ampere Ratings 1-30 35-60 70-100 110-200 225-400 450-600 700-800 1000-1200 Carton Qty. 10 10 5 1 1 1 1 1 Weight* Lbs. 0.12 0.23 0.36 0.14 0.25 0.44 0.80 1.45 Kg. 0.054 0.104 0.163 0.063 0.113 0.200 0.363 0.658 *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1025 Recommended fuseblocks/fuseholders for Class T 300V fuses • Open fuseblocks - see pages 59-60 • Modular fuseblocks - see page 67 Ampere Ratings 1-30 35-60 70-100 110-200 225-400 450-600 800 Carton Qty. 10 10 5 1 1 1 1 Weight* Lbs. 0.33 0.82 0.51 0.192 0.46 0.85 1.65 Kg. 0.149 0.371 0.231 0.087 0.208 0.385 0.748 *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1029 Recommended fuseblocks/fuseholders for Class T 600V fuses • Open fuseblocks - see pages 61-62 • Modular fuseblocks - see page 67 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 19 ® Electrical - Power Fuses Bussmann Time-Delay Class G Fuses Physical Size: Fuse (Amps) A (Length) (Length) SC-⁄Ω™ to -15 1.319 SC-20 1.419 SC-25 to -30 1.639 SC-35 to -60 2.259 .41" (10.3mm) SC Fast Acting (⁄Ω™-6A), Class G Time-Delay (7-60A), Class G Construction: Melamine Tube Ampere Ratings: ⁄Ω™-60A Voltage Rating: ⁄Ω™-20: 600Vac/170Vdc 25-60: 480Vac/300Vdc (only UL) Interrupting Rating: 100,000A RMS Sym., 10,000A dc Agency Information: Std. 248-5, Class G, UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-01, File 53787 Catalog Symbol & Current Ratings SC-⁄Ω™ SC-6 SC-25 SC-1 SC-7 SC-30 SC-1⁄Ω™ SC-8 SC-35 SC-2 SC-9 SC-40 SC-2⁄Ω™ SC-10 SC-45 SC-3 SC-12 SC-50 SC-4 SC-15 SC-60 SC-5 SC-20 — Carton Quantity and Weight Ampere Ratings Carton Qty. Weight* Lbs. Kg. ⁄Ω™-15 4 0.06 0.03 20 4 0.06 0.03 25-30 2 0.04 0.02 35-60 2 0.08 0.03 • Compact branch-circuit units with high interrupting rating and current limitation. • With a 600 volt rating, they can be used in 120/208, 120/240 and 277/480 volt circuits. • Length variations relative to case size make the “rejection” type fuses. • SC fuses with ampere ratings above 6 amps have a degree of overload time-delay which permits them to pass temporary overloads. At 200% load, they have a minimum opening time of 12 seconds. Recommended fuseblocks/fuseholders for Class G • Open fuseblocks - see page 64 • Panel-mount fuseholders - see page 78 • In-line fuseholders - see page 80 *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1024 (0-60) 20 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Low-Peak® Time-Delay, Class CC Fuses 20 25 30 3 3⁄Ω™ 4 4⁄Ω™ 6 8 10 12 15 ⁄Ω™ flΩ¡º °Ω¡º 1 1⁄Ω¢ Time Current Characteristics—Average Melt AMPERE RATING 200 100 10 LP-CC Low-Peak Fuse Time-Delay Current Limiting, Class CC - Rejection Type Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Ampere Ratings: ⁄Ω™ - 30A Voltage Rating: 600Vac (or less), 300Vdc (⁄Ω™-2°Ω¡ºA & 20-30A), 150Vdc (3-15A) Interrupting Rating: 200,000A RMS Sym; 20,000A dc Construction: Melamine Tube Agency Information: Std. 248-4, Class CC UL Listed, Guide JDDZ, File E4273 CSA Certified; Class 1422-02, File 53787 TIME IN SECONDS ® 1 .1 Catalog Symbol LP-CC-°Ω¡º LP-CC-3 LP-CC-9 LP-CC-1 LP-CC-3¤Ω¡º LP-CC-10 LP-CC-1⁄Ω• LP-CC-3⁄Ω™ LP-CC-12 LP-CC-1⁄Ω¢ LP-CC-4 LP-CC-15 LP-CC-1›Ω¡º LP-CC-4⁄Ω™ LP-CC-20 LP-CC-1⁄Ω™ LP-CC-5 LP-CC-25 LP-CC-1flΩ¡º LP-CC-5flΩ¡º LP-CC-30 LP-CC-1°Ω¡º LP-CC-6 LP-CC-2 LP-CC-6⁄Ω¢ LP-CC-2⁄Ω¢ LP-CC-7 Recommended fuseblocks/fuseholders for Class CC 600V fuses • Open fuseblocks - see page 64 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78 • In-line fuseholders - see page 80 .01 1000 LP-CC-8 100 LP-CC-7⁄Ω™ LP-CC-2°Ω¡º 10 LP-CC-2⁄Ω™ LP-CC-flΩ¡º 1 LP-CC-⁄Ω™ .4 600Vac CURRENT IN AMPERES Current-Limiting Effects Prospective ShortCircuit Current *Let-Thru Current (Apparent RMS Symmetrical) 1⁄Ω¢ A 2°Ω¡ºA 15A 25A 30A 1000 100 135 240 20A 305 380 435 3000 140 210 350 440 575 580 5000 165 255 420 570 690 710 10,000 210 340 540 700 870 1,000 20,000 260 435 680 870 1,090 1,305 30,000 290 525 800 1,030 1,300 1,520 40,000 315 610 870 1,150 1,390 1,700 50,000 340 650 915 1,215 1,520 1,820 60,000 350 735 1,050 1,300 1,650 1,980 80,000 390 785 1,130 1,500 1,780 2,180 100,000 420 830 1,210 1,600 2,000 2,400 200,000 525 1,100 1,600 2,000 2,520 3,050 *RMS Symmetrical Amperes Short-Circuit NOTE: To calculate Ip (Ipeak) multiply IRMS value ≈ 2.3. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1023 (0-30) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 21 ® Electrical - Power Fuses Bussmann Class CC Rejection-Type Fuses FNQ-R KTK-R Limitron® Fuse Time-Delay, Rejection Type Branch Circuit Fuse Class CC Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Construction: Melamine Tube Ampere Ratings: ⁄Ω¢-30A. Voltage Rating: 600Vac or less Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-4, Class CC UL Listed, Guide JDDZ, File E4273 CSA Certified, Class 1422-01, File 53787 Fast Acting; Branch Circuit Fuse Class CC - Rejection Feature Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Construction: Melamine Tube Ampere Ratings: ⁄Ω¡º-30A. Voltage Rating: 600Vac (or less). Interrupting Rating: 200,000A RMS Sym. Agency Information: Std. 248-4, Class CC UL Listed, Guide JDDZ, File E4273 CSA Certified, File 53787, Class 1422-02 Catalog Symbol & Current Ratings 600Vac Catalog Symbol & Current Ratings KTK-R-⁄Ω¡º KTK-R-1 FNQ-R-⁄Ω¢ FNQ-R-1flΩ¡º FNQ-R-7 KTK-R-⁄Ω• KTK-R-1⁄Ω™ KTK-R-8 FNQ-R-‹Ω¡º FNQ-R-1°Ω¡º FNQ-R-7⁄Ω™ KTK-R-¤Ω¡º KTK-R-2 KTK-R-9 FNQ-R-›Ω¡º FNQ-R-2 FNQ-R-8 KTK-R-⁄Ω¢ KTK-R-2⁄Ω™ KTK-R-10 FNQ-R-⁄Ω™ FNQ-R-2⁄Ω¢ FNQ-R-9 KTK-R-‹Ω¡º KTK-R-3 KTK-R-12 FNQ-R-flΩ¡º FNQ-R-2⁄Ω™ FNQ-R-10 KTK-R-›Ω¡º KTK-R-3⁄Ω™ KTK-R-15 FNQ-R-‹Ω¢ FNQ-R-2°Ω¡º FNQ-R-12 KTK-R-⁄Ω™ KTK-R-4 KTK-R-20 FNQ-R-°Ω¡º FQN-R-3 FNQ-R-15 KTK-R-flΩ¡º KTK-R-5 KTK-R-25 FNQ-R-1 FNQ-R-3¤Ω¡º FNQ-R-17⁄Ω™ KTK-R-‹Ω¢ KTK-R-6 KTK-R-30 FNQ-R-1⁄Ω• FNQ-R-3⁄Ω™º FNQ-R-20 FNQ-R-1⁄Ω¢ FNQ-R-4 FNQ-R-25 FNQ-R-1‹Ω¡º FNQ-R-5 FNQ-R-1›Ω¡º FNQ-R-6 FNQ-R-30 — FNQ-R-1⁄Ω™ FNQ-R-6⁄Ω¢ — 600Vac KTK-R-7 Time-Current Curves on page 226. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Time-Current Curves on page 225. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1014 Data Sheet: 1015 Recommended fuseblocks/fuseholders for Class CC 600V fuses • Open fuseblocks - see page 64 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78 • In-line fuseholders - see page 80 22 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann ⁄‹Ω£™∑ ≈ 1‹Ω•∑ Supplementary Fuses BBS KTQ Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1‹Ω•∑ (10.3mm ≈ 35mm) Construction: Fibre Cartridge Interrupting Rating: 10,000A RMS Sym. Ampere Ratings: ⁄Ω¡º-30A Voltage Rating: 600Vac (⁄Ω¡º-5A), 250Vac (6-10A), 48Vac (12-30A) Agency Information: Std. 248-14 UL Listed, 0-5A/600V, Guide JDYX, File E19180 CSA Certified, 0-5A/600V, Class 1422-01, File 53787 Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1‹Ω•∑ (10.3mm ≈ 34.9mm) Construction: Fibre Cartridge Ampere Ratings: 1-6A Voltage Rating: 600Vac Interrupting Rating: 10,000A RMS Sym. Agency Information: Std. 248-14 UL Recognized, 4-6A, Guide JDYX2, File E19180 Catalog Symbol & Current Ratings 600Vac KTQ-1 Catalog Symbol & Current Ratings 600Vac BBS-⁄Ω¡º BBS-¤Ω¡º BBS-⁄Ω¢ BBS-›Ω¡º BBS-⁄Ω™ BBS-flΩ¡º BBS-‹Ω¢ BBS-°Ω¡º BBS-1 BBS-1⁄Ω™ BBS-1flΩ¡º BBS-1°Ω¡º BBS-2 BBS-3 BBS-4 BBS-5 250Vac BBS-6 BBS-7 BBS-8 BBS-10 — — — — — — — — — — — — 48Vac BBS-12 BBS-15 BBS-20 BBS-25 BBS-30 — — — — — — — — — — — KTQ-1flΩ¡º KTQ-2 KTQ-3 KTQ-4 KTQ-5 KTQ-6 Data Sheet: 2045 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2010 (0-30A) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Recommended fuseblocks/fuseholders for 13/32” x 1-1/2” fuses • Open fuseblocks - see page 64, 66 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78-79 • In-line fuseholders - see page 80-81 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 23 ® Bussmann Electrical - Power Fuses ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Supplementary Fuses BAF BAN KTK and KLM Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Construction: Fibre Tube; Nickel Plated Brass Endcaps Voltage Rating: 250Vac (¤Ω¡º-15A), 125Vac (20-30A) Interrupting Rating: 10,000A at 125Vac Agency Information: Std. 248-14 UL 0-15/250V, Guide JDYX, File E19180 CSA Certified, 0-15/250V, Class 1422-01, File 53787 Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) - 5AG Construction: Fibre Tube Voltage Rating: 250Vac Interrupting Ratings: Military Tested 35A (1.1.-3.5A) 100A (3.6-10A) 200A (10.1-15A) 750A (15.1-30A) Catalog Symbol & Current Ratings Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Construction: Melamine Tube; Nickel Plated Brass Endcaps Voltage Rating: KTK - 600Vac or less KLM - ⁄Ω¡ º -⁄Ω• A: 500Vac/600Vdc ¤Ω¡ º -10A: 500Vac/dc, 12-30A: 500Vac/600Vdc Interrupting Rating: 100,000A - KTK; 10,000A - KLM, RMS SYM. (UL) Agency Information: Std. 248-14 KTK-UL Listed, Guide JDYX, File E19180 KLM-UL Recognized, Guide JFHR2, File E56412 CSA Certified, File 53787, Class 1422-01, HRC-Misc 250V IR* BAF-¤Ω¡ º 250V IR* BAF-1⁄Ω™ BAF-⁄Ω¢ BAF-1°Ω¡ º 250V IR* BAF-6⁄Ω¢ BAF-7 IR IR BAF-2 100A BAF-8 35A BAF-2⁄Ω™ BAF-9 125V BAF-20 Catalog Symbol & Current Ratings IR BAF-25 10000A IR 200A BAF-30 250V 250V 250V BAN-1 BAN-5 BAN-12 250V BAN-30 BAN-2 BAN-6 BAN-15 — BAN-3 BAN-8 BAN-20 — BAN-4 BAN-10 BAN-25 — Recommended Fuseblocks BAF-°Ω¡ º BAF-3 BAF-10 — BAF-1 BAF-4 BAF-12 — Amps Poles Terminal Type Screw Pressure with Plate w/ Quick Quick Connect Connect — BAF-5 — ⁄Ω¡ º 1 BM6031SQ BM6031PQ BM6031B KTK-¤Ω¡ º KTK-1⁄Ω¢ KTK-6 KTK-20 — BAF-6 — to 2 BM6032SQ BM6032PQ BM6032B KTK-⁄Ω¢ KTK-1⁄Ω™ KTK-7 KTK-25 30 3 BM6033SQ BM6033PQ BM6033B KTK-‹Ω¡ º KTK-2 KTK-7⁄Ω™ KTK-30 KTK-›Ω¡ º KTK-2⁄Ω™ KTK-8 — KTK-⁄Ω™ KTK-3 KTK-9 — KTK-flΩ¡ º KTK-3⁄Ω™ KTK-10 — BAF-⁄Ω™ BAF-flΩ¡ º IR IR 200A BAF-15 750A — — *All have interrupting rating of 10,000A at 125V. Data Sheet: 2011 (0-30) Data Sheet: 2046 (0-30) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings 600Vac - UL Listed and C.S.A. Box Lug KTK-⁄Ω¡ º KTK-‹Ω¢ KTK-4 KTK-⁄Ω• KTK-1 KTK-5 KTK-15 *500Vac/dc - UL Recognized and C.S.A. Recommended fuseblocks/fuseholders for 13/32” x 1-1/2” fuses • Open fuseblocks - see page 64, 66 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78-79 • In-line fuseholders - see page 80-81 KLM-⁄Ω¡ º KLM-‹Ω¢ KLM-5 KLM-20 KLM-⁄Ω• KLM-1 KLM-6 KLM-25 KLM-¤Ω¡ º KLM-1⁄Ω™ KLM-8 KLM-30 KLM-⁄Ω¢ KLM-2 KLM-10 — KLM-‹Ω¡ º KLM-3 KLM-12 — KLM-⁄Ω™ KLM-4 KLM-15 — *KLM-(⁄Ω¡ º-⁄Ω• & 12-30): 500VAC/600Vdc CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: KTK-1011 KLM-2020 24 KTK-12 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Supplementary Fuses FNM Fusetron® Fuse FNQ Time-Delay Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5 AG) (10.3mm ≈ 38.1mm) Construction: Fibre Tube Ampere Ratings: ⁄Ω¡ º - 30A. Voltage Rating: 250Vac (or less). Interrupting Rating: See Table Below. Agency Information: Std. 248-14 UL Listed, 0-10/250V; 12-15/125V; File E19180, Guide JDYX CSA Certified, 1-10/250V; Class 1422-01, 12-15/125V; File 53787 NOTE: For 250V applications from 12-30A use FNW. Time-Delay Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5 AG) (10.3mm ≈ 38.1mm) Construction: Fibre Tube Ampere Ratings: ⁄Ω¡ º - 30A Voltage Rating: 500Vac or less Interrupting Rating: 10,000A RMS Sym. Agency Information: Std. 248-14 UL Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787 Catalog Symbol & Current Ratings FNQ-⁄Ω¡º FNQ-°Ω¡º FNQ-3¤Ω¡º FNQ-8 FNQ-⁄Ω• FNQ-1 FNQ-3⁄Ω™ FNQ-9 FNQ-⁄fiΩ¡ºº FNQ-1⁄Ω• FNQ-4 FNQ-10 FNQ-‹Ω¡§ FNQ-1⁄Ω¢ FNQ-4⁄Ω™ FNQ-12 FNQ-¤Ω¡º FNQ-1⁄Ω™ FNQ-5 FNQ-14 FNQ-⁄Ω¢ FNQ-1flΩ¡º FNQ-5flΩ¡º FNQ-15 FNQ-‹Ω¡º FNQ-2 FNQ-6 FNQ-20 FNQ-›Ω¡º FNQ-2⁄Ω¢ FNQ-6⁄Ω¢ FNQ-25 FNQ-⁄Ω™ FNQ-2⁄Ω™ FNQ-7 FNQ-30 FNQ-flΩ¡º FNQ-3 — — 250Vac FNM-⁄Ω¡º FNM-⁄Ω• FNM-⁄fiΩ¡ºº FNM-¤Ω¡º FNM-⁄Ω¢ FNM-‹Ω¡º FNM-›Ω¡º FNM-⁄Ω™ FNM-flΩ¡º FNM-‹Ω¢ FNM-°Ω¡º FNM-1 — 250Vac IR 35A @ 250Vac 10,000A @ 125Vac FNM-1⁄Ω• FNM-1⁄Ω¢ FNM-1›Ω¡º FNM-1⁄Ω™ FNM-1flΩ¡º FNM-1°Ω¡º FNM-2 FNM-2⁄Ω¢ FNM-2⁄Ω™ FNM-2°Ω¡º FNM-3 FNM-3¤Ω¡º FNM-3⁄Ω™ IR 125Vac 200A @ 250Vac 10,000A @ 125Vac FNM-12 FNM-15 — — 32Vac FNM-20 FNM-25 FNM-30 — — FNM-4 FNM-4⁄Ω™ FNM-5 FNM-5flΩ¡º FNM-6 FNM-6⁄Ω¢ FNM-7 FNM-8 FNM-9 FNM-10 250Vac IR 100A @ 250Vac 10,000A @ 125Vac Catalog Symbol & Current Ratings 500Vac Data Sheet: 1012 IR CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 10,000A @ 125Vac Recommended fuseblocks/fuseholders for 13/32” x 1-1/2” fuses • Open fuseblocks - see page 64, 66 • Finger-safe fuseholders - see pages 41-44, 65 • Panel-mount fuseholders - see page 78-79 • In-line fuseholders - see page 80-81 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2028 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 25 ® Bussmann Electrical - Power Fuses Plug Fuses W Series SL and TL Series S and T Series Fast Acting Ampere Ratings: ⁄Ω™ - 12A Voltage Rating: 125Vac IR: 10,000A RMS Sym. Element is a simple fusible, metal link. For general purpose circuit protection. Quickly opens when short-circuit or overload occurs. Use for lighting and other non-motor circuits. Edison base. Agency Information: Std. 248-11 UL Listed, Guide JEFV, File E12112 Time-Delay, Loaded Link Ampere Ratings: 15 - 30A Voltage Rating: 125Vac IR: 10,000A RMS Sym. Heat absorbing metal bead on element link for time-delay. Passes motor overload starting currents without needlessly opening. Edison base (TL), Rejection base (SL). Agency Information: Std. 248-11 UL Listed, Guide JEFV, File E12112 Time-Delay, Dual-Element Ampere Ratings: Type S: ⁄Ω¢ - 30A Type T: ‹Ω¡º - 30A Voltage Rating: 125Vac IR: 10,000A RMS Sym. For all-purpose application. Like two fuses in one. A simple link element for short-circuits and dangerous overloads plus a series-connected element which lets the harmless overload starting currents of motors pass without opening. Uses less energy; operates cooler; provides superior protection. Edison base (T), Rejection base (S). Agency Information: Std. 248-11 Type S: UL Listed (0-6⁄Ω¢) Guide JFHR, File E56412 (7-30A) Guide JEFV, File E12112; CSA Certified, Class 1423-01, File 53787 Type W W-⁄Ω™ W-1 W-1°Ω¡º W-2 W-2⁄Ω™ W-3 W-4 W-5 W-6 W-6⁄Ω™ W-7 W-8 W-10 W-12 Type SL SL-15 SL-20 SL-25 SL-30 Type TL TL-15 TL-20 TL-25 TL-30 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Type S S-⁄Ω¢ S-‹Ω¡º S-›Ω¡º S-⁄Ω™ S-flΩ¡º S-°Ω¡º S-1 S-1⁄Ω• S-1⁄Ω¢ S-1›Ω¡º S-1flΩ¡º S-1°Ω¡º S-2 S-2⁄Ω¢ S-2⁄Ω™ S-2°Ω¡º S-3 S-3¤Ω¡º S-3⁄Ω™ S-4 S-4⁄Ω™ S-5 S-5flΩ¡º S-6 S-6⁄Ω¢ S-7 S-8 S-9 S-10 S-12 S-14 S-15 S-20 S-25 S-30 Type T T-‹Ω¡º T-›Ω¡º T-⁄Ω™ T-flΩ¡º T-°Ω¡º T-1 T-1⁄Ω• T-1⁄Ω¢ T-1›Ω¡º T-1flΩ¡º T-1°Ω¡º T-2 T-2⁄Ω¢ T-2⁄Ω™ T-2°Ω¡º T-3 T-3¤Ω¡º T-3⁄Ω™ T-4 T-4⁄Ω™ T-5 T-5flΩ¡º T-6 T-6⁄Ω¢ T-7 T-8 T-9 T-10 T-12 T-14 T-15 T-20 T-25 T-30 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1036 26 Data Sheet: 1033 (SL) & 1035 (TL) Data Sheet: 1032 (S) & 1034 (T) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Electrical - Power Fuses Bussmann Plug Fuses Dual-Element Fustat® Fuses and Adaptors for Small Motor Protection. (Both Motor Running and Short-Circuit Protection) Fustat Fuse Adaptors Fustat Adaptors (various ampere ratings) screw into the “Edison” Thread fuse sockets of standard household fuse boxes. Adaptors serve the purpose of preventing the wrong size fuse from being used. Carton Catalog Number Prefix Ampere Rating SA(Branch Circuits) 15, 20, 30 SA(Single Motor Circuits) 1, 1⁄Ω¢, 1flΩ¡º, 2, 2⁄Ω™, 3¤Ω¡º, 4, 5, 6⁄Ω¢, 8, 10 ENA Edison base neutral Qty. 4 Wt. 0.03 (lbs) Adaptor Accepts Fuses SA-1 S-1 or smaller SA-1-1/4 S-1-1/4 or smaller SA-1-6/10 S-1-6/10 or smaller SA-2 S-2 or S-1-8/10 SA-2-1/2 S-2-1/2 to S-1-8/10 SA-3-2/10 S-3-2/10 to S-1-8/10 SA-4 S-4 to S-3-1/2 SA-5 S-5 to S-3-1/2 SA-6-1/4 S-6-1/4 to S-3-1/2 SA-8 S-8 to S-7 SA-10 S-10 to S-7 SA-15 S-15 to S-7 SA-20 S-20 SA-30 S-30 to S-20 Branch Circuit Protection Adaptor Accepts Fuses SA-15 S-15 to S-7 SA-20 S-20 SA-30 S-25 SA 30 S-30 to S-20 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 27 ® Electrical - Power Fuses Bussmann Cable Limiters & Welder Limiters K Series 68000 & 64000 Series Cable Limiters Interrupting Rating: 200,000A, 600Vac RMS Symmetrical UL Listing: KDM, KDR, KDP and KFM Welder Limiters for Class H and J Fuseholders Voltage Rating: 600Vac or less Interrupting Rating: 200,000 Amps RMS Symmetrical Catalog Symbol & Current Ratings Type Fuseholder Copper Cable Limiter — 600 Volts Catalog Symbol Cable Size Catalog Symbol Cable Size KCY #4 KCF 4/0 KCZ #3 KCH 250 MCM KCA #2 ††KCJ 350 MCM KCB #1 †† †KCM 500 MCM KCC 1/0 KCV 600 MCM ††KCD 2/0 ††KCR 750 MCM KCE 3/0 KCS 1000 MCM Tubular Terminals Class H Tubular Terminal and Offset Bolt-Type Terminal KQV #12 KDD 2/0 KQT #10 KDE 3/0 KFZ #8 KDF 4/0 KIG #6 KDH 250 MCM KDY #4 ††KDJ 350 MCM KDA #2 †KDM1 500 MCM KDB #1 KDU 600 MCM KDC 1/0 ††KDR1 750 MCM Compression Connector Rod Terminal and Tubular Terminal KEX 4/0 KFH-A 250 MCM KQO 350 MCM ††KDT 500 MCM Class J Catalog Number Amp Rating (Nominal) 68150 150 68200 200 Carton Quantity Weight Each Lbs. Kg. 1 1.40 0.63 1 2.75 1.25 68300 300 68400 400 68600 600 1 4.25 1.92 64200 200 1 1.00 0.45 64300 300 1 1.75 0.79 64400 400 1 1.75 0.79 64600 600 1 3.50 1.59 • Current-limiting devices designed specially for use on welder circuits only. • Time-current characteristics are designed to hold on the intermittent overloading encountered in welder operation, while providing short-circuit protection to the circuit and equipment. • Welder limiters have excess current capacity in the operating range as needed for this type of service. • Because of the special characteristics of the welder limiters, they are not intended for application on general-use circuits. *Center Bolt-Type Terminal and Off-Set Bolt-Type Terminal KPF 4/0 KDP1 500 MCM KFT 250 MCM KFM1 750 MCM KEW 350 MCM †Available with molded rubber boots. Add “–B” to end of part number. ††Available with shrink tube “_V” suffix. *Copper or aluminum cable; sizes of all other limiters pertain to copper only. UL Listed (File E90818) 1 • Crimp Tool: TBM-14M • Die: 15506 KDM 15515 KDR Data Sheet: 1042 28 Data Sheet: 1045 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Bussmann Electronic – PC Board and Small Dimension Fuses 5mm ≈ 15mm Fuses C515 (Axial Leads) C519 C518 (Axial Leads) C520 Time-Delay Physical Size: 0.197∑ ≈ 0.591∑ (5mm ≈ 15mm) Construction: Glass Tube Agency Information: UL Listing File E19180, Guide JDYX 125mA-250mA and 375mA-3A CSA Certification File LR65063, Class 1422-01, 125mA-250mA and 375mA-3A UL Recognized, File E19180, Guide JDYX2, 350mA and 3.5A-7A Fast-Acting Physical Size: 0.197∑ ≈ 0.591∑ (5mm ≈ 15mm) Construction: Glass Tube Agency Information: UL Listing File E19180, Guide JDYX CSA Certification File LR65063, Class 1422-01 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Current Rating Rated Voltage ac Electrical Characteristics Interrupting Rating Current Rating 125mA 35A/250V 10kA/125V 100mA 250mA p.f. = 0.7 - 0.8 125mA 350mA 35A/250V 10kA/125V 250mA 25A/600V p.f. = 0.7 - 0.8 375mA 500mA 35A/250V 750mA 600mA 10kA/125V 1A 250V Interrupting Rating CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Current Rating Max. Rated Voltage ac Interrupting Rating p.f. = 1.0 35A/250V 10kA/125V 3A 350V* p.f. = 0.7 - 0.8 100A/250Vac p.f. = 0.7 - 0.8 10kA/125Vac p.f. = 0.7 - 0.8 250V *350Vac/100A is UL Recognized 1.5A p.f. = 0.7 - 0.8 1A 2A 1.25A 2.5A 1.5A 3A 100A/250V 10kA/125V p.f. = 0.7 - 0.8 1.6A 100A/250V 3.5A 2A 10kA/125V 4A 200A/250V 10kA/125V5A p.f. = 0.7 - 0.8 5A p.f. = 0.7 - 0.8 2.25A Fast-Acting, Light Ballast Protection Physical Size: 0.197∑ ≈ 0.591∑ (5mm ≈ 15mm) Construction: Ceramic Agency Information: UL Listing File E19180, Guide JDYX CSA Certification File LR65063, Class 1422-01 UL Recognized, File E19180, Guide JDYX2 100A/350Vac 500mA 375mA 750mA Rated Voltage dc C517 (Axial Leads) 2.5A 3A 3.5A 4A 5A 125V 400A/125V p.f. = 1.0 7A Data Sheet: 2006 (C515) & 2007 (C519) Data Sheet: 2026 (C518) & 2027 (C520) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 2025 29 ® Bussmann Electronic – PC Board and Small Dimension Fuses 5mm ≈ 20mm — IEC Standards GDA GDA-V (Axial Leads) GDB GDB-V (Axial Leads) GDC GDC-V (Axial Leads) Fast-Acting, High Breaking Capacity Physical Size: 0.197∑ ≈ 0.788∑ (5mm ≈ 20mm) Construction: Ceramic Tube End caps: Nickel plated brass Voltage Rating: 250Vac or less Interrupting Rating: 1500A @ 250Vac Agency Information: UL Recognized, Guide JDYX2, File E19180, 50mA and 315mA-6.3A SEMKO Approval 50mA, 200mA and 315mA-6.3A IEC 127-SI VDE Approval 1.25A-6.3A Fast-Acting, Low Breaking Capacity Physical Size: 0.197∑ ≈ 0.788∑ (5mm ≈ 20mm) Construction: Glass Tube End caps: Nickel plated brass Voltage Rating: 250Vac or less Interrupting Rating: 35A @ 250Vac Agency Information: Designed to IEC (Pub 127) Sheet II British Standard Approval SEMKO Approval VDE Approval, IMQ UL Recognized, Guide JDYX2, File E19180, 32mA-6.3A Time Delay, Low Breaking Capacity Physical Size: 0.197∑ ≈ 0.788∑ (5mm ≈ 20mm) Construction: Glass Tube End caps: Nickel plated brass Voltage Rating: 250Vac or less Interrupting Rating: 35A @ 250Vac Agency Information: Designed to IEC (Pub 127) Sheet III British Standard Approval SEMKO Approval VDE Approval, IMQ UL Recognized, Guide JDYX2, File E19180, 32mA-6.3A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Electrical Characteristics Current Rating I2t 50mA 63mA 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA 800mA 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A 0.0017 0.0005 0.0011 0.0018 0.0037 0.008 0.020 0.027 0.010 0.018 0.038 0.064 0.097 0.480 0.9 1.9 2.0 3.9 8.1 14 25 48 Data Sheet: 2014 30 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Max Voltage Drop (mV) 9000 3300 2600 2300 1900 1600 1350 1300 1400 1200 1050 1200 490 230 200 180 205 190 160 160 155 150 Current Rating CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Max Voltage Drop (mV) Current Rating I2t 32mA 0.000047 10000 40mA 0.00011 8000 50mA 0.00020 3200 63mA 0.00057 2500 80mA 0.0012 2200 100mA 0.003 2100 125mA 0.005 2000 160mA 0.008 1950 200mA 0.016 1600 250mA 0.028 1400 315mA 0.058 1150 400mA 0.018 950 500mA 0.018 220 630mA 0.035 220 800mA 0.067 180 1A 0.60 200 1.25A 0.84 200 1.6A 1.6 190 2A 4.2 160 2.5A 6.1 145 3.15A 13 130 4A 22 120 5A 42 115 6.3A 69 110 8A* — — 10A* — — 12A* — — 16A* — — *IEC Standard 127 Sheet II does not include ratings above 6.3A. 32mA 40mA 50mA 63mA 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA 800mA 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A 0.0014 0.0034 0.006 0.012 0.015 0.022 0.034 0.052 0.078 0.17 0.41 0.61 0.75 1.3 3.1 3.6 7 10 17 34 56 91 133 270 Data Sheet: 2015 Data Sheet: 2016 I2t* Max Voltage Drop (mV) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 1050 920 800 760 580 490 390 320 340 270 250 210 168 158 132 85 80 80 80 80 75 75 75 65 ® Bussmann Electronic – PC Board and Small Dimension Fuses 5mm ≈ 20mm – N. American Standards GMA GMA-V (Axial Leads) Fast Acting Physical Size: 0.197∑ ≈ 0.788∑ (5mm ≈ 20mm) Construction: Glass Tube End Caps; nickel plated brass Agency Information: Std. 248-14 UL Listed Guide JDYX, File E19180, 0-6A UL Recognized, Guide JDYX2, File E19180, 7-15A CSA Certified, Class 1422-01, File E65063, 0-6A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. GMC GMC-V (Axial Leads) GMD GMD-V (Axial Leads) Medium TimeDelay Physical Size: 0.197∑ ≈ 0.788∑ (5mm ≈ 20mm) Construction: Glass Tube End Caps; nickel plated brass Agency Information: Std. 248-14 UL Listed Guide JDYX, File E19180, 06.3A UL Recognized, Guide JDYX2, File E19180, 7-8A CSA Certified, Class 1422-01, File 65063, 0-6.3A Time-Delay Physical Size: 0.197∑ ≈ 0.788∑ (5mm ≈ 20mm) Construction: Glass Tube End Caps; nickel plated brass Agency Information: Std. 248-14 UL Listed Guide JDYX, File E19180, 0-3A UL Recognized, Guide JDYX2, File E19180, 4A CSA Certified, Class 1422-01, File 65063, 0-3A Electrical Characteristics Electrical Characteristics Rated Voltage (Vac) Rated Voltage (Vac) Current Rating 63mA 100mA 125mA 200mA 250mA 300mA 315mA 500mA 600mA 750mA 800mA 1A 1.25A 1.5A 1.6A 2A 2.5A 3.15A 3.5A 4A 5A 6A 7A 8A 10A 15A Breaking Capacity 35A/250V 10kA/125V p.f. = 0.7 – 0.8 250 100A/250V 10kA/125V p.f. = 0.7 – 0.8 10kA/125V p.f. = 0.7 – 0.8 125 200A/125V p.f. = 1.0 150A/125V p.f. = 1.0 Data Sheet: 2017 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Current Rating 63mA 80mA 100mA 125mA 150mA 200mA 250mA 300mA 315mA 400mA 500mA 600mA 630mA 750mA 800mA 1A 1.25A 1.5A 1.6A 2A 2.5A 3A 3.15A 3.5A 4A 5A 6A 6.3A 7A 8A 10A Breaking Capacity 35A/250V 10kA/125V p.f. = 0.7 – 0.8 250 100A/250V 10kA/125V p.f. = 0.7 – 0.8 Electrical Characteristics Current Rating 125mA 150mA 200mA 250mA 300mA 315mA 400mA 500mA 600mA 630mA 750mA 800mA 1A 1.2A 1.25A 1.5A 1.6A 2A 2.5A 3A 4A Rated Voltage (Vac) Breaking Capacity 250 100A/250V 10kA/125V p.f. = 0.7 – 0.8 200A/250V 10kA/125V, p.f. = 1 10kA/125V p.f. = 0.7 – 0.8 125 200A/125V p.f. = 1.0 Data Sheet: 2018 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet:2019 31 ® Bussmann Electronic – PC Board and Small Dimension Fuses ⁄Ω¢ ∑ Diameter ≈ fiΩ• ∑ to 1∑ Lengths AGA AGA-V* (Axial Leads) AGW Fast Acting Physical Size: ⁄Ω¢∑ ≈ fiΩ•∑ (1AG) (6.4mm ≈ 15.9mm) Construction: Glass Tube Voltage Rating: See table below. Agency Information: Std. 248-14 UL File E19180, UL Listed, Guide JDYX 0-1⁄Ω™ A UL Recognized, Guide JDYX2 2-12A, AGX AGX-V (Axial Leads)* Fast Acting Physical Size: ⁄Ω¢∑ ≈ ‡Ω•∑ (7AG) (6.4mm ≈ 22.2mm) Construction: Glass Tube Voltage Rating: 32V Catalog Symbol & Current Ratings 32Vac AGW-1 AGW-4 AGW-15 AGW-1⁄Ω™ AGW-5 AGW-20 AGW-2 AGW-6 AGW-25 AGW-2⁄ Ω™ AGW-7⁄Ω™ AGW-30 AGW-3 AGW-10 — Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1∑ (8AG) (6.4mm ≈ 25.4mm) Construction: Glass Tube Voltage Rating: See table below. Agency Information: Std. 248-14 UL File E19180 UL Listed, Guide JDYX, 0-5A UL Recognized, Guide JDYX2, 6-20A CSA File 47233; Class 1422-01, 0-5A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc. Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings Catalog Symbol & Current Ratings 250Vac/35A (⁄ Ω∞ºº-⁄Ω™ A), 100A (‹Ω¢ -1⁄Ω™ A) 125Vac/10kA (⁄Ω¡ §-1⁄Ω™ ), 200A (2-5A) AGX-⁄ Ω∞ºº AGX-‹Ω¡ § AGX-‹Ω¢ AGA-⁄Ω¡ § AGA-⁄Ω™ AGA-2 AGX-⁄Ω™ºº AGX-¤Ω¡ º AGX-1 AGA-⁄Ω¡ º AGA-flΩ¡ º AGA-2⁄Ω™ AGX-⁄Ω¡ ºº AGX-⁄Ω¢ AGX-1⁄Ω¢ AGA-⁄ Ω• AGA-‹Ω¢ AGA-3 AGX-⁄Ω£ ™ AGX-‹Ω¡ º AGX-1⁄Ω™ AGA-⁄Ω¢ AGA-1 AGA-5 AGX-⁄Ω¡ § AGX-‹Ω• AGX-2 AGA-‹Ω• AGA-1⁄Ω™ — AGX-⁄Ω¡ º AGX-›Ω¡ º — AGX-⁄Ω• AGX-⁄Ω™ — AGX-2⁄Ω™ AGX-4 AGX-6 AGX-3 AGX-5 AGX-7 32Vac/1kA AGA-6 AGA-10 AGA-25 AGA-7 AGA-15 AGA-30 AGA-7⁄Ω™ AGA-20 125Vac/10kA — 32 V/1kA AGX-8 AGX-15 AGX-25 AGX-10 AGX-20 AGX-30 *AGA-V is UL Listed 0-5A, UL Recognized 6-12A * AGX-V is UL Recognized from 6-20A @ 32Vac Data Sheet: 2039 32 Data Sheet: 2040 Data Sheet: 2041 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Bussmann Electronic – PC Board and Small Dimension Fuses ⁄Ω¢ ∑ Diameter ≈ 1∑ Lengths TDC180 TDC600 FWH British Household Plug Fuse Fast/Medium Physical Size: ⁄Ω¢∑ ≈ 1∑ (6.4mm ≈ 25.4mm) Construction: Ceramic Tube End Caps: Silver-plated copper Agency Information: BS1362, IEC 269-3A Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1∑ (6.3mm ≈ 25.4mm) Construction: Ceramic Tube Voltage Rating: 600Vac Agency Information: UL Recognized, Std. 248-14, BS1362 Catalog Symbol & Current Ratings TDC600-2A Semiconductor Fuse Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (6.3mm ≈ 32mm) Construction: Ceramic Tube Voltage Rating: 500Vac/50kA (.25-20A) 500Vac/20kA (25A, 30A) Agency Information: Std. 248-14 UL Recognized .25-7, 500Vac, File E91958, Guide JFHR2 UL Recognized 10-30, 500Vac, File E56412, Guide JFHR2 Catalog Symbol & Current Ratings TDC600-10A 240Vac TDC180-1 TDC180-5 TDC180-13 TDC180-2 TDC180-7 — TDC180-3 TDC180-10 — CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings FWH-.250A6F FWH-010A6F FWH-.500A6F FWH-12.5A6F FWH-001A6F FWH-015A6F FWH-002A6F FWH-016A6F FWH-3.15A6F FWH-020A6F FWH-005A6F FWH-025A6F FWH-6.30A6F FWH-030A6F FWH-007A6F CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2042 Data Sheet: 2081 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 720038 (Fuse) Time-Current 35785256, 50955 33 ® Bussmann Electronic - PC Board and Small Dimension Fuses ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fast Acting Fuses TDC10 Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG) (6.3mm ≈ 32mm) Construction: Glass Tube Voltage Rating: See Below Agency Information: Conforms to British Standard BS-2950A, I.R. 10Im@Vm. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings AGC AGC-V (Axial Leads) ABC ABC-V (Axial Leads) Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG) (6.3mm ≈ 32mm) Construction: Glass Tube Nickel Plated Brass End Caps Voltage Rating: See Below Interrupting Rating: See Below Agency Information: Std. 248-14 UL Listed, Guide JDYX, File E19180, 0-10A UL Recognized, Guide JDYX2, File E19180, 15-30A CSA Certification, Class 1422-01, File 53787 Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AB) (6.3mm ≈ 32mm) Construction: Ceramic Tube Nickel Plated Brass End Caps Voltage Rating: See Below Interrupting Rating: See Below Agency Information: Std. 248-14 UL Listed, Guide JDYX File E19180, 0-15A UL Recognized, Guide JDYX2, File E19180, 20-25A CSA Certification, Class 1422-01, File 53787, 0-15A, Class 1422-30, File 53787, 20-25A 1000Vac 250Vac TDC10-50mA TDC10-1.5A TDC10-60mA TDC10-2A TDC10-100mA TDC10-3A TDC10-150mA TDC10-5A TDC10-250mA 150Vac 750Vac TDC10-7A TDC10-500mA 100Vac 500Vac TDC10-10A TDC10-750mA 32Vac Electrical Characteristics 350Vac TDC10-12A TDC10-1A TDC10-15A Current Rating — TDC10-20A — TDC10-25A Data Sheet: 2043 34 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Rated Voltage ac (Max.) Electrical Characteristics Interrupting Rating1 ac ⁄Ω™º 250V 35A ⁄Ω¡ § 250V 35A ⁄Ω¡ º 250V 35A ⁄Ω• 250V 35A ‹Ω¡ § 250V 35A ¤Ω¡ º 250V 35A ⁄Ω¢ t250V 35A ‹Ω¡ º 250V 35A ‹Ω• 250V 35A ›fiΩ¡ ºº t250V 35A ⁄Ω™ 250V 35A ‹Ω¢ 250V 35A 1 250V 35A 1⁄Ω¢ 250V 100A 1⁄ Ω™ 250V 100A 2 250V 100A 2⁄Ω¢ 250V 100A 2⁄Ω™ 250V 100A 3 250V 100A 4 250V 200A 5 250V 200A 6 250V 200A 7 250V 200A 8 250V 200A 9 250V 200A 10 250V 200A 15 32V 1000A 20 32V 1000A 25 32V 1000A 30 32V 1000A 1Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 248. Data Sheet: 2001 Current Rating Rated Voltage ac (Max.) Interrupting Rating1 dc (Max.) ac dc ⁄Ω¢ ⁄Ω™ ‹Ω¢ 250V 250V 250V 125V 125V 125V 35A 35A 35A 10kA 10kA 10kA 1 1⁄Ω™ 2 250V 250V 250V 125V 125V 125V 35A 100A 100A 10kA 10kA 10kA 2⁄Ω™ 3 4 250V 250V 250V 125V 125V 125V 100A 100A 200A 10kA 10kA 10kA 5 6 7 250V 250V 250V 125V 125V 125V 200A 200A 200A 10kA 10kA 10kA 8 10 15 250V 250V 250V 125V 125V 125V 200A 200A 750A 10kA 10kA 10kA 20 25 30 250V 125V 125V 125V 125V 125V 400A 1000A 1000A 10kA 400A 400A 1Interrupting ratings were measured at 70% – 80% power factor on AC, and at a time constant described in UL 248. Data Sheet: 2000 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Bussmann Electronic - PC Board and Small Dimension Fuses ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fuses GBB GBB-V (Axial Leads) TDC11 Very Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AB) (6.3mm ≈ 32mm) Construction: Ceramic Cartridge Nickel Plated Brass End Caps Voltage Rating: 250Vac/125Vdc Interrupting Rating: 200A @ 250Vac 10kA @ 125Vac/dc (1-15A), 200A @ 125Vac/dc (20-30A) Agency Information: Std. 248-14 UL Recognized, 1-30, 125Vdc/250Vac, File E56412, Guide JFHR2 CSA Certified, 1-10, 125Vdc/250Vac, File 53787, Class 1422-01 Time Lag Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG) (6.3mm ≈ 32mm) Construction: Glass Tube Voltage Rating: See Below Interrupting Rating: 10 times rated current @ Vm. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. MDL MDL-V (Axial Leads) Time-Delay Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG) (6.3mm ≈ 32mm) Construction: Glass Tube Nickel Plated Brass End Caps Voltage Rating: See Below Interrupting Rating: See Below Agency Information: Std. 248-14 UL Listed, Guide JDYX, File E19180; ⁄Ω¡§ -8A CSA Certification Class 1422-01, File 53787, ⁄Ω¡§ -8A UL Recognized, Guide JDYX2, File E19180, 8.1-30A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol and Current Ratings Electrical Characteristics 1000Vac 250Vac Catalog Symbol and Current Ratings TDC11-50mA TDC11-1.5A Current Rating GBB-1 GBB-6 GBB-15 TDC11-60mA TDC11-2A GBB-1⁄Ω¢ GBB-7 GBB-20 TDC11-100mA TDC11-3A GBB-2 GBB-8 GBB-25 TDC11-150mA TDC11-5A GBB-3 GBB-9 GBB-30 TDC11-250mA 150Vac GBB-4 GBB-10 — 750Vac TDC11-7A GBB-5 GBB-12 — TDC11-500mA 100Vac 500Vac TDC11-10A TDC11-750mA — 350Vac — TDC11-1A — Data Sheet: 2013 Rated Voltage ac (Max.) Interrupting Rating1 ac ⁄Ω¡ § 250V 35A ⁄Ω¡ º 250V 35A ⁄Ω• 250V 35A ¤Ω¡ º 250V 35A ‹Ω¡ § 250V 35A ⁄Ω¢ 250V 35A ‹Ω¡ º 250V 35A ‹Ω• 250V 35A ⁄Ω™ 250V 35A ‹Ω¢ 250V 35A 1 250V 35A 1⁄Ω¢ 250V 100A 1⁄Ω™ 250V 100A 2 250V 100A 2⁄Ω¢ 250V 100A 2⁄Ω™ 250V 100A 3 250V 100A 4 250V 200A 5 250V 200A 6 250V 200A 7 250V 200A 8 250V 200A 9 32V 1000A 10 32V 1000A 12 32V 1000A 15 32V 1000A 20 32V 1000A 25 32V 1000A 30 32V 1000A 1Interrupting ratings were measured at 70% – 80% power factor on ac, and at a time constant described in UL 198L. Data Sheet: 2043 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet:2004 35 ® Bussmann Electronic - PC Board and Small Dimension Fuses ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ and ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses MDQ MDQ-V (Axial Leads) MDA MDA-V (Axial Leads) Dual Element Time-Delay Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG) (6.3mm ≈ 32mm) Construction: Glass Tube; Nickel Plated Brass End Caps Agency Information: Std. 248-14 UL Listed, File E19180; Guide JDYX, ⁄Ω¡§-7A CSA Certification, File 47233, Class 1422-01, ⁄Ω¡§-7A UL Recognized, Guide JDYX2, File E19180, 7.1-30A Time-Delay Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AB) (6.3mm ≈ 32mm) Construction: Ceramic Tube; Nickel Plated Brass End Caps Agency Information: Std. 248-14 UL Listed, Guide JDYX, File E19180, 0-15A CSA Certification, Class 1422-01, File 53787, 0-15A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. MDQ-‹Ω• MDQ-1°Ω¡º MDQ-⁄Ω£™ MDQ-›Ω¡º MDQ-2 MDQ-⁄Ω¡§ MDQ-⁄Ω™ MDQ-2⁄Ω¢ MDQ-⁄Ω¡º MDQ-flΩ¡º MDQ-2⁄Ω™ MDQ-⁄Ω• MDQ-‹Ω¢ MDQ-2°Ω¡º MDQ-⁄fiΩ¡ºº MDQ-°Ω¡º MDQ-3 MDQ-⁄‡fiΩ¡ººº MDQ-1 MDQ-3¤Ω¡º MDQ-‹Ω¡§ MDQ-1¤Ω¡º MDQ-4 MDQ-¤Ω¡º MDQ-1⁄Ω¢ MDQ-5 MDQ-⁄Ω¢ MDQ-1⁄Ω™ MDQ-6 MDQ-‹Ω¡º MDQ-1flΩ¡º MDQ-6⁄Ω¢ MDQ-7⁄Ω™ MDQ-9 MDQ-12 MDQ-8 MDQ-10 MDQ-15 MDQ-7 32Vac CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings 250Vac 32Vac AGU-1 AGU-4 AGU-20 AGU-50 AGU-2 AGU-5 AGU-25 AGU-60 AGU-3 AGU-8 AGU-30 — — AGU-10 AGU-35 — — AGU-15 AGU-40 — Current Rating Rated Voltage ac (Max.) dc (Max.) Interrupting Rating1 ac dc ¤Ω¡ º ⁄Ω¢ ⁄Ω™ 250V 250V 250V 35A 35A 35A ‹Ω¢ 1 1⁄Ω™ 250V 250V 250V 35A 35A 100A 2 2⁄Ω™ 3 250V 250V 250V 100A 100A 100A 4 5 6 250V 250V 250V 200A 200A 200A 7 8 10 250V 250V 250V 200A 200A 200A MDA-12 Voltage: 250Vac (⁄Ω¡ººA-7A) 32Vac (7⁄Ω™A-7A) Interrupting Rating: 35A @ 250Vac (⁄Ω¡§A-1A) 100A @ 250Vac (1⁄Ω¢A-3A) 200A @ 25Vac (4A-7A) 1kA @ 32Vac (7⁄Ω™A-12A) Data Sheet: 2044 36 Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5 AG) (10.3mm ≈ 38.1mm) Construction: Glass Tube No Agency Listings Electrical Characteristics 250Vac MDQ-⁄Ω¡ºº AGU 15 20 25 250V 250V 250V 125V 125V 1500A 1500A 1000A 10kA 10kA 30 250V 125V 1000A 10kA 1Interrupting ratings were measured at 70% – 80% power factor on ac, and at a time constant described in UL 248. Data Sheet: 2002 Data Sheet: 2008 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ® Bussmann Electronic - PC Board and Small Dimension Fuses Pin Indication Type GBA and GLD MIC and MIN FNA Fast Acting Physical Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG) (6.6mm ≈ 31.8mm) Agency Information: Std. 248-14 UL Listed, 0-5A/125Vac, 10,000 AIC, Guide JDYX, File E19180 UL Recognized, 6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC Guide JDYX2, File E19180 CSA Certified: 0-5A/125Vac, 10,000 AIC Class 1422-01, File 53787 General Information: Type GBA has a “red” pin for high visibility. Type GLD has an Albaloy-plated pin for positive, electrical signal circuit activation. Fast Acting Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5AG) (10.3mm ≈ 38.1mm) Agency Information: Std. 248-14 MIC—0-15A UL Listed, Guide JDYX, File E19180 MIN—1-5A CSA Certified, Class 1422-01, File 53787 General Information: Type MIN has a “red” pin for high visibility. Type MIC has a silver-plated pin for positive, electrical signal activation. Time-Delay Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Agency Information: Std. 248-14 UL Listed ⁄Ω¡º-°Ω¡ºA, IR 35A@ 250V CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings GLD-⁄Ω™ GLD-2 GLD-6 GLD-‹Ω¢ GLD-3 GLD-10 GLD-1 GLD-4 GLD-12 GLD-1⁄Ω™ GLD-5 GLD-15 GBA-⁄Ω™ GBA-2 GBA-8 GBA-‹Ω¢ GBA-3 GBA-10 GBA-1 GBA-4 GBA-15 GBA-1⁄Ω™ GBA-5 IR 10kA@ 125V 1-15A, IR 10kA@ 125V Guide JDYX, File 19180 CSA Certified, 0-°Ω¡º A/250V, 1-10A/125V, Class 1422-01, File 53787 General Information: Fuses above 10A have dual-tube construction. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Symbol & Current Ratings 250Vac 32V MIC-1 (IR = 35A) MIC-5 (IR = 200A) MIC-20 (IR = 10kA) MIC-2 (IR = 100A) MIC-10 (IR = 200A) MIC-25 (IR = 10kA) MIC-3 (IR = 100A) MIC-15 (IR = 750A) MIC-30 (IR = 10kA) MIC - (1-15)UL Listed 125Vac / IR = 10kA 250Vac Catalog Symbol & Current Ratings 250Vac IR* 125Vac IR 125Vac IR 125Vac FNA-⁄Ω¡ º FNA-1 FNA-3 FNA-9 FNA-⁄Ω• FNA-1⁄Ω• FNA-3¤Ω¡ º FNA-10 FNA-⁄fiΩ¡ ºº FNA-1⁄Ω¢ FNA-3⁄Ω™ FNA-12 10,000A 32V FNA-¤Ω¡ º MIN-1 (IR = 35A) MIN-5 (IR = 200A) MIN-20 (IR = 10kA) FNA-⁄Ω¢ MIN-2 (IR = 100A) MIN-10 (IR = 200A) MIN-25N (IR = 10kA) FNA-›Ω¡ º FNA-1°Ω¡ º FNA-5flΩ¡ º FNA-25 FNA-⁄Ω™ FNA-2 FNA-6 FNA-30 MIN-3 (IR = 100A) MIN-15 (IR = 750A) MIN-30 (IR = 10kA) FNA-flΩ¡ º FNA-2⁄Ω¢ FNA-6⁄Ω¢ — FNA-‹Ω¢ FNA-2⁄Ω™ FNA-7 — FNA-°Ω¡ º FNA-2°Ω¡ º FNA-8 — FNA-‹Ω¡ º FNA-1›Ω¡ º IR 35A FNA-1⁄Ω™ FNA-4 IR FNA-15 FNA-4⁄Ω™ FNA-1flΩ¡ º 10,000A FNA-5 IR IR 10,000A 32 Volts† FNA-20 IR% 1kA@ 32V *Interrupting rating of 10,000A at 125V. †Interrupting rating of 1,000A at 32V. Data Sheet: 2012 Data Sheet: 2047 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 2029 37 ® Bussmann Electronic - PC Board and Small Dimension Fuses Pin Indication Type/Actuators/Limiters ANN Limiter MIS KAZ Non-Time-Delay Physical Size: ⁄‹Ω£™∑ ≈ 2∑ (10.3mm ≈ 50.8mm) Voltage Rating: 600Vac Interrupting Rating: 200,000 AIC Actuator (Not a Fuse) Physical Size: ⁄‹Ω£™∑ ≈ 2∑ (10.3mm ≈ 50.8mm) Voltage Rating: 600Vac Interrupting Rating: 200,000A Agency Information: UL Listed, Guide JDVS, File E58836 Recommended Use: Mounts in Buss signal blocks 2778, 2837 and 2838. General Information: Connects in parallel with fuses having a rating of 50 amperes or larger and opens at 10A or more. Catalog Symbol & Current Ratings 600Vac MIS-1 MIS-4 MIS-10 MIS-2 MIS-5 MIS-12 MIS-3 MIS-8 Test Specifications Fuse Load Opening Time All 110% 4 hrs. (min.) 1-5A 150% 6 min. (max.) 6-12A 150% 12 min. (max.) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Very Fast Acting Physical Size: ‡Ω•∑ ≈ 3‹Ω¡§∑ (22.2mm ≈ 81.0mm) Voltage Rating: 125Vac IR = 2500A 80Vdc IR = 2700 A Agency Information: 35-400A @ 125Vac, IR=2500A and 80Vdc, IR=2700A: UL Recognized Guide JFHR2, File E56412; CSA Certified Class 1422-30, File 53787 CE for 35-400A Fuseholder: 4164 Catalog Symbol & Current Ratings ANN-10 ANN-90 ANN-225 ANN-400 ANN-35 ANN-100 ANN-250 ANN-500 ANN-40 ANN-125 ANN-275 ANN-600 ANN-50 ANN-150 ANN-300 ANN-700 ANN-60 ANN-175 ANN-325 ANN-800 ANN-80 ANN-200 ANN-350 Data Sheet: 2023 & 2133 ANL Non-Time Delay Voltage Rating: 80Vdc Agency Information: UL Recognized, CSA Certified, 35-750A @ 80Vdc, IR = 2700A Guide JFHR2, File E56412 Class 1422-30, File 53787 Fuseholder: 4164 Catalog Symbol & Current Ratings ANL-35 ANL-40 ANL-50 ANL-60 ANL-80 ANL-100 Data Sheet: 2021 38 ANL-125 ANL-130 ANL-150 ANL-175 ANL-200 ANL-225 ANL-250 ANL-275 ANL-300 ANL-325 ANL-350 ANL-400 Data Sheet: 2024 & 2133 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 ANL-500 ANL-600 ANL-675 ANL-750 — — ® Bussmann Electronic - PC Board and Small Dimension Fuses In-Line Fuse and Fuseholders GLR *HLR Fast Acting, Non-rejecting Voltage Rating: 300Vac or less Interrupting Rating: 10,000A Agency Information: Std. 248-14 UL Listed, 0-15A/300Vac (Guide JDYX, File E19180) CSA Certified, 0-10A/300V (Class 1422-01, File 53787) GMF and GRF Fuseholder Time Delay, Non-rejecting Voltage Rating: 300Vac or less Interrupting Rating: 10,000A Agency Information: Std. 248-14 0-10A, UL Listed (Guide JDYX, File E19180) CSA Certified, (Class 1422-01, File 53787) Electrical Ratings for Type GMF and GRF Fuses and Non-Rejection Style Carriers Electrical Ratings for Type GLR Fuses and Non-Rejection Style Carriers Fuse Carrier1, 2 Fuse Carrier1, 2 Fuse Carrier1, 2 Fuse Carrier1, 2 GLR-‹Ω¡ § GLR-⁄Ω™ GLR-1 GLR-1 ⁄Ω™ GLR-1 flΩ¡ º GLR-2 GLR-3 GLR-4 HLR HLR HLR HLR HLR HLR HLR HLR GLR-5 GLR-6 GLR-7 GLR-8 GLR-9 GLR-10 GLR-12 GLR-15 HLR HLR HLR HLR HLR HLR HLR HLR-2A GMF-‹Ω¡ º GMF-⁄Ω™ GMF-flΩ¡ º GMF-°Ω¡ º GMF-1 GMF-1⁄Ω¢ GMF-1flΩ¡ º GMF-2 GMF-2 ⁄Ω™ GMF-2 °Ω¡ º HLR HLR HLR HLR HLR HLR HLR HLR HLR HLR GMF-3 GMF-3 ¤Ω¡ º GMF-4 GMF-5* GMF-6 ⁄Ω¢ GMF-10 GRF-7 GRF-8 GRF-10 HLR HLR HLR HLR HLR HLR HLR HLR HLR 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042” *For two leads order HLR-2A, 15A, 300V • An alternative to the HLR fuseholder is the A fuseholder. The A fuseholder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. • Do not put tension on line (rear) terminal of fuseholder. 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042” *For two leads order HLR-2A, 15A, 300V • An alternative to the HLR fuseholder is the A fuseholder. The A fuseholder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. • Do not put tension on line (rear) terminal of fuseholder. CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2032 Data Sheet: 2031 GLQ HLQ3 Fast-Acting, Size Rejecting Voltage Rating: 300Vac or less Interrupting Rating: 10,000A Agency Information: Std. 248-14 UL Listed (Guide JDYX, File E19180) CSA Certified, (Class 1422-01, File 53787) Fuseholder Time-Delay, Size Rejecting Voltage Rating: 300Vac or less Interrupting Rating: 10,000A Agency Information: Std. 248-14 UL Listed (Guide JDYX, File E19180) CSA Certified, (Class 1422-01, File 53787) GMQ Electrical Ratings for Type GMQ Fuses and Rejection Style Carriers Electrical Ratings for Type GLQ Fuses and Rejection Style Carriers Fuse Carrier3, 4 Fuse Carrier3, 4 Fuse Carrier3, 4 Fuse Carrier3, 4 GLQ-1 GLQ-1⁄Ω™ GLQ-1flΩ¡ º GLQ-2 GLQ-2 ⁄Ω™ HLQ-1flΩ¡ º HLQ-1flΩ¡ º HLQ-1flΩ¡ º HLQ-3 ¤Ω¡ º HLQ-3 ¤Ω¡ º GLQ-3 GLQ-4 GLQ-5 GLQ-9 GLQ-10 HLQ-3 ¤Ω¡ º HLQ-5 HLQ-5 HLQ-10 HLQ-10 GMQ-⁄Ω™ GMQ-flΩ¡ º GMQ-°Ω¡ º GMQ-1 GMQ-1⁄Ω¢ GMQ-1flΩ¡ º GMQ-2 HLQ-⁄Ω™ HLQ-1flΩ¡ º HLQ-1flΩ¡ º HLQ-1flΩ¡ º HLQ-1flΩ¡ º HLQ-1flΩ¡ º HLQ-3 ¤Ω¡ º GMQ-2⁄Ω™ GMQ-3 GMQ-3 ¤Ω¡ º GMQ-4 GMQ-6 GMQ-6 ⁄Ω¢ HLQ-3 ¤Ω¡ º HLQ-3 ¤Ω¡ º HLQ-3 ¤Ω¡ º HLQ-5 HLQ-8 3) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac. 4) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042” • Do not put tension on line (rear) terminal of fuseholder. CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 3) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac. 4) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042” • Do not put tension on line (rear) terminal of fuseholder. CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2033 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 2030 39 ® Bussmann Electronic - PC Board and Small Dimension Fuses Blade-Type Fuses ATC® Blade-Type Fuse ATM Mini–Fuse® MAX Maxi–Fuse® Fast Acting Voltage Rating: 32Vdc Interrupting Rating: 1,000A Agency Information: UL Recognized, (3-40A) (Guide JFHR2, File E56412) Fast Acting Voltage Rating: 32Vdc Interrupting Rating: 1,000A Fast Acting Voltage Rating: 32Vdc Interrupting Rating: 1,000A Catalog Symbol & Current Ratings Catalog Symbol & Current Ratings Catalog Symbol & Current Ratings ATC-1 Black ATM-2 Gray MAX-20 Yellow ATC-2 Gray ATM-3 Violet MAX-30 Green ATC-3 Violet ATM-4 Pink MAX-40 Orange ATC-4 Pink ATM-5 Tan MAX-50 Red ATC-5 Tan ATM-7⁄Ω™ Brown MAX-60 Blue ATC-7⁄Ω™ Brown ATM-10 Red MAX-70 Tan ATC-10 Red ATM-15 Blue MAX-80 Clear ATC-15 Blue ATM-20 Yellow ATC-20 Yellow ATM-25 Clear ATC-25 Clear ATM-30 Green ATC-30 Green ATC-40 Orange Refer to page 82 for In-Line Fuseholders for Blade Type Fuses. Refer to page 82 for In-Line Fuseholders for Blade Type Fuses. Refer to page 82 for In-Line Fuseholders for Blade Type Fuses. Data Sheet: 2009 40 Data Sheet: 2048 Data Sheet: 2049 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Optima® Three Pole Overcurrent Protection Module Fuseholder Wire Range: 75°CU Only #18-12 Single/Dual, torque 15 lb: in. #10-8 Single/Dual, torque 20 lb: in. Dual wire. Wire with same guage and type 75°CU Only Solid Class CC Version Catalog Symbol: OPM-NG-SC3 Electrical Rating: 30A, 600Vac (or less) Withstand Rating: 200kA Use with Class CC fuse type: LP-CC, FNQ-R, KTK-R Stranded Agency Information: UL OPM-NG-SC3 UL Listed, UL 512, File E14853, Guide IZLT OPM-NG-SM3 UL Recognized, UL512, File E14853, Guide IZLT2 CSA Certified, C22.2 No. 39, Class C6225-01, File 47235 IEC 60947-3 Utilization Category AC20B Packaging Weight: 0.39lb. (0.18 kg) Handling & Storage Specifications: Storage Temperature: -10°C to 65°C Attributes: • 45mm width matches IEC starters. • Phil-slot screws. • Pressure plate terminations. • Integrated collapsible handle. • Fuse carrier cannot be removed from holder base. • IP20 finger safe to IEC60529 • Auxilliary contacts. - optional accessory • Dual-wire rated terminals (see Wire Table). • 35mm DIN rail or panel mounting feature. Maximum screw size #8 (M4). • Padlockable CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. [mm2 ] 18-8 x1 18-8 x2 18-8 x1 18-8 x2 1..6 x1 1..6 x2 1.5..6 x1 1.5..6 x2 1..4 x1 1..4 x2 Ferrules (Nm)/lb in 18-12Single/Dual 15 lb in 1 . 7 (N m ) 10-8 Single/Dual 20 lb in 2 . 5 (N m) Input Power Terminal Wire Range: Wiring 13/32” x 1-1/2” and 10,3 x 38mm Version Catalog Symbol: OPM-NG-SM3 Electrical Rating: UL and CSA 30A, 600Vac (or less) IEC 32A, 690Vac (or less) Withstand Rating: Limited by fuse IR, 200kA maximum Use with 13/32” x 1-1/2” fuse types: KTK, FNQ, KLM Use with 10 x 38mm fuse types: FWA, FWC, C10G_ _, C10M_ _ AWG (1) #14 to #2 (1.5 to 25mm2 ) conductor or (2) #14 to #6 (1.5 to 10mm2 ) conductors (1) #14 to #2 (1.5 to 25mm2 ) conductor or (2) #12 to #6 (2.5 to 10mm2 ) conductors 20 lb..in. (2.2 N.m) 15 lb..in. (1.7 N.m) Solid Conductor Stranded Conductor Tightening Torque: Connector Screw Clamp Materials: Housing: Thermoplastic- UL V-2 Clip: Tin plated copper alloy Contact Lubricant: Fluoroether grease Saddle screw: Plated steel DIN rail springs: Stainless steel Optional Accessories: Comb Bar (Max. current rating = 63A) OPMNGSA245 OPMNGSA254 OPMNGSA272 OPMNGSA345 OPMNGSA354 OPMNGSA445 OPMNGSA454 OPMNGSA472 OPMNGSA554 2 2 2 3 3 4 4 4 5 circuit, circuit, circuit, circuit, circuit, circuit, circuit, circuit, circuit, 45mm 54mm 72mm 45mm 54mm 45mm 54mm 72mm 54mm between between between between between between between between between same same same same same same same same same phases phases phases phases phases phases phases phases phases Input Terminal Block OPMNGSA005 OPMNGSA009 Input/Feed Through Power Terminal, Supports feed through to another system, DIN-rail mount only Input Power Terminal Cover OPMNGSA010 Protective Cover for unused terminals on comb bar Auxilliary Contacts OPMNGSAAUX11 OPMNGSAAUX20 NO/NC NO/NO Marking Tabs OPMNGSA101 Marking Tab - Mounts to front of carrier, quantity 100 Data Sheet: 1109 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 41 Fuseblocks, Holders and Terminal Blocks Bussmann® Optima® Three Pole Overcurrent Protection Module Optional Accessories Dimensional Data Millimeters (± 0.38) Inches (± .015) Data Sheet: 1109 42 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Optima® Overcurrent Protection Module - Fuseholder Product Features • “Open” fuse indication lights. • Cam action handle for easy removal. • Finger safe terminals. (Qualified as IP20 per IEC 529) • Removable module for convenient fuse loading. • 35mm DIN-rail or screw panel mounting (#8 screw, 1⁄Ω¢” long). • Dead-front construction. • Padlockable. Additional Features • Option for remote “open fuse” status indication feature available (less downtime!). See BIF document for additional wiring details. • Offered with Class CC rejection clips or European 10 ≈ 38mm clips to meet global needs. • Wire ready: Saves time as terminals are ready to accept wires. Catalog Symbol: Series O P M - 1 0 3 Fuse Type Communication Blank - 10 x 38mm or 13/32” x 1-1/2” R - Class CC C - Communication Feature 8 Dimensional Data Midget (Non-Rejection) European LP-CC KTK C10M KTK-R FNM C10G FNQ-R FNQ Physical Characteristics • Small size matches 45mm IEC starter width. • Accepts #8-18 AWG stranded, #10-18 AWG solid wire. • 3-pole. OPM-1038 30A, 600V UL/CSA** (Max. 3 Watts per fuse) 32A, 660V IEC OPM-1038R 30A, 600V UL/CSA** OPM-1038C 30A, 600V UL/CSA** (Max. 3 Watts per fuse) 32A, 660V IEC OPM-1038RC 30A, 600V UL/CSA** SC Rating * 200kA * 200kA Clips Non-rejection, 10 x38mm or 13/32” x 1-1/2” Rejection, Class CC Non-rejection, 10 x38mm or 13/32” x 1-1/2” Rejection, Class CC BUSS Recommended Fuse Types Non-Switch Series Catalog Number Electrical Rating Communication Port IL1 4T2 1.76 ∑ (± .03) (44.7mm) (± .7 ) 6T3 Non-Switch Series for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10mm x 38mm) Fuses Materials: Grey Thermoplastic UL Flammability: UL 94V0 Agency Information: UL (see table) CSA Certified, C22.2 No. 39, Class 6225-01, File 47235 IEC (see table) Shipping Weight: Approximately 213g/.47 lb. Carton Quantity: 1 Class CC 3.22∑ (± .03) (81.8mm) (± .76) 2T1 3L2 .27∑ (6.9mm) 5L3 .74∑ (18.8mm) .31∑ (7.9mm) 3.60∑ (± .03) (91.4mm) (± .76) .57∑ (14.5mm) 3.74∑ (± .03) (95.0mm) (± .76) 3.17∑ (80.5mm) Communication Port 1.65∑ (± .03) (41.9mm) (±. 76) 0.23∑ (5.8mm) .50∑ (12.7mm) .44∑ (11.2mm) .224" (5.6mm) 1.312∑ (± .01) (33.3mm) (± .25) Panel Mount Hole Pattern 3.60∑ (± .03) (91.4mm) (± .76) 1.86∑ (± .03) (47.2mm) (± .76) Panel Mount Hole Pattern CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Remote Open Fuse Indication Std. UL Information File Guide No Recognized UL 512 E14853 IZLT2 No Listed UL 512 E14853 IZLT Yes Recognized UL 512 E14853 IZLT2 Yes Listed UL 512 E14853 IZLT IEC CE IEC 269-2-1 Yes Yes IEC 269-2-1 No No *Rating varies depending on fuse used in module; 200kA maximum **DC voltage rating: 600V UL/CSA Data Sheet: 1102 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 43 Fuseblocks, Holders and Terminal Blocks Bussmann® Optima® Overcurrent Protection Module - Fuseholder and Disconnect Switch Physical Characteristics • Small size matches 45mm IEC starter width. • Accepts #8-18 AWG stranded, #10-18 AWG solid wire. • 3 pole. • Handle and shaft required for through the door operation. See BIF document for details. Catalog Symbol: Series Fuse Type Communication O P M - 1 0 3 8 S W Blank - 10 x 38mm or 13/32” x 1-1/2” R - Class CC C - Communication Feature 5.72∑ (± .045) (145.3mm) (± 1.14) Dimensional Data 4.25∑ (± .03) (108.0mm) (± .76) 0.43∑ (± .03) (10.9mm) (± .76) 1.38∑ (35.0mm) 2T1 4T 2 6T3 1L1 BUSS Load Break Disconnect Switch for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10mm x 38mm) Fuses Materials: Grey Thermoplastic UL Flammability: UL 94V0 Agency Information: UL (see table) CSA Certified, C22.2 No. 39, Class 6225-01, File 47235 IEC (see table) Shipping Weight: Approximately 335g/.74 lb. Carton Quantity: 1 Product Features • “Open” Fuse indication lights. • Finger safe terminals.(Qualified as IP20 per IEC 529) • Cam action handle for easy module removal. • 35mm DIN-rail or screw panel mounting (#8 screw, 1⁄Ω¢” long). • Dead front construction. No exposed contacts for added safety. • Padlockable. • Option for remote “open fuse” status indication feature available (reduces downtime!). See BIF document for additional wiring details. • Offered with Class CC rejection clips or European 10 ≈ 38mm clips to meet global needs. • Wire ready: Saves time as terminals are ready to accept wires. Communication Port 1.76∑ .27∑ (6.9mm) (44.7mm) 3L2 5L3 .74∑ (18.8mm) .31∑ (7.9mm) Horsepower Rating of Switch 3PH V 0.57∑ (± .03) (14.5mm) (± .76) 240 480 600 5 10 15 HP 3.74∑ (± .03) (95.0mm) (± .76) Recommended Fuse Types Class CC Midget (Non-Rejection) European LP-CC KTK C10M KTK-R FNM C10G FNQ-R FNQ Switch Series Catalog Number OPM-1038SW Electrical Rating 30A, 600Vac UL/CSA OPM-1038RSW 32A, 660Vac IEC 30A, 600Vac UL/CSA OPM-1038SWC 30A, 600Vac UL/CSA 32A, 660Vac IEC OPM-1038RSWC 30A, 600Vac UL/CSA 0.23∑ (5.8mm) .50∑ (12.7mm) .44∑ (11.2mm) .224∑ (5.6mm) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Communication Port 3.17∑ (80.5mm) 1.86∑ (47.2mm) Panel Mounting Hole Pattern 3.60∑ (91.4mm) 1.312∑ (± .01) (33.3mm) (± .25) Panel Mounting Hole Pattern SC Remote Open Rating Clips Fuse Indication * Non-rejection, No 10x38mm or 13/32” x 1-1/2” 100kA Rejection, No Class CC * Non-rejection, Yes 10x38mm or 13/32” x 1-1/2” 100kA Rejection, Yes Class CC UL Information Std. File Guide Recognized UL 508 Listed UL 508 Recognized UL 508 Listed UL 508 E161278 NLRV2 E161278 NLRV E161278 NLRV2 E161278 NLRV IEC IEC 947-3 Yes Yes IEC 947-3 *Rating varies depending on fuse used in module; 100kA maximum Data Sheet: 1103 44 CE For complete specification data, call Bussmann Information Fax ~ 636.527.1450 No No Blank Page 45 Do Not Print Fuseblocks, Holders and Terminal Blocks Bussmann® SAMI Fuse Covers Dimensional Data (inches) Catalog Number** Description A B C SAMI-1_ 600V, J (0-30A) and 600V, T (35-60A)* 250V, RK, K5, H (35-60A) 5.02 1.03 1.94 SAMI-2_ 600V, RK, K5, H (0-30A) 7.03 1.30 2.07 SAMI-3_ 600V, J (65-100A) 7.03 1.30 2.33 SAMI-4_ 250V, RK, K5, H (65-100A) 8.20 1.30 2.18 SAMI-5_ 600V, RK, K5, H (35-60A) 8.20 1.30 2.18 SAMI-6_ 600V, J (35-60A) 4.98 1.17 2.14 SAMI-7_ 600V, Midget, Class CC, G (0-30A) SAMI-8†_ 600V, RK, K5, H (65-100A) SAMI-9_ 3.82 0.75 1.72 10.38 1.50 2.33 3.82 0.75 1.72 250V, RK, K5, H (0-30A) and 600V, T (0-30A) *Available in non-indicating only. †SAMI-8A adapter available for small fusetron body design. SAMI-8I and SAMI-8N come standard with adapter (SAMI-8A). **Catalog Numbers For Indicating Cover, add suffix I. For Non-indicating cover, add suffix N. Example: SAMI-7I = Indicating SAMI-7N = Non-indicating SAMI Series WARNING: To avoid electrical shock, turn power off before installing, removing or servicing. Dimensional Data TEST PROBE LINE TEST PROBE Buss SAMI -2 • Innovative design, covers exposed terminals and contacts of Bussmann fuseblocks. • Fits most competitive fuseblocks. • Buss Yellow light on indicating SAMI shows when the fuse is open—helps trouble shoot the system and reduces downtime. • All versions are reusable—no need to pay for indication every time a fuse opens. • Indication contacts have teeth to break oxidation layer on the existing fuse endcap to provide a clear signal path. • Less than .6mA leakage current at 600 volt. • Visual marking of line and load side. • SAMI cover ends can easily be cut away if necessary, to fit cover over existing wiring or to fit most safety switches. • Dead front construction provides added protection against accidental contact by maintenance personnel. • Labels are provided with the SAMI fuse cover for writing in circuit or fuse information. • One cover is required for each pole. Indicating feature requires a minimum of 90Vac or 115Vdc to illuminate lamp. LOAD For Class J, RK1, RK5, H, K5, CC, G (0-30A) and Midget type fuses. Voltage Rating: Non-Indicating - 0-600Vac/dc Indicating - 90 to 600Vac -115 to 600Vdc Ampere Rating: 0-100A Agency Information: UL Listed; SAMI-1I through SAMI-6I SAMI-8I and SAMI-9I, SAMI-1N through SAMI-6N, SAMI-8N and SAMI-9N UL Recognized; SAMI-7I and SAMI-7N CSA Certified, File LR47235-93C B A FUSE CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1204 (Trimming Guides: 12041, 12042, 12043, 12044, 12045, 12046, 12048, 12049) 46 C For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 250V H250 Series For use with Class H Fuses (Bussmann NON and REN). R250 Series For use with Class R Fuses (Bussmann LPN-RK and FRN-R, DLN-R and KTN-R). Construction: Thermoplastic, UL Flammability: 94VO Ampere Ratings: ⁄Ω¡º-600A. Withstand Ratings: H250 Series - 10,000A RMS Sym.; R250 Series - 200,000A RMS Sym. Voltage Rating: H250, 250V; R250, 250V Agency Information: UL Listed UL512, Guide IZLT, File E14853; CSA Certified, Class 6225-01, File 47235 Class H Fuseblocks (250V) Catalog Data (for NON and REN Fuses) Copper Only 0.25∑ Quick Connect — — Clip w/ Reinforced Spring (Copper Only) — — P P P PR PR PR C C C CR COR CR COR CR COR CO CO CO Q Q Q Fig. No. 1 2 3 — — — — C C CR CR COR COR CO CO — — 4 5 Clip with Reinforced Spring SR SR SR Pressure Plate & Clip with Reinforced Spring — H25060-1 H25060-2 S S S Dimensions (Inches) – See Next Page For Figures Pressure Plate 1 2 Clip with Reinforced Spring 31 to 1 2 3 Basic Catalog Number H25030-1 H25030-2 H25030-3 Poles Amps ⁄Ω¡º to 30 — Terminal Type (Suffix No.) Screw Box Lug w/ A B C D E F G H 1.25 — 1.31 J Dia. x C’ Bore K (See Figures) 4.25 1.73 1.5 2.81 1.5 0.5 0.5 60 3 H25060-3 — — — — C CR COR CO — 6 61 to 100 101 to 200 201 to 400 401 1 2 3 H25100-1 H25100-2 H25100-3 — SR — SR — SR — — — — — — — CR — CR — CR COR COR COR — — — — — — 7 8 9 4.125 1 3 H25200-1 — — — — — CR — — — 10 H25200-3 — — — — — CR — — — 11 1 H25400-1 — — — — — CR* — — — 10 9.06 4.0 3.0 3.02 0.63 1.75 3.0 1.0 3 H25400-3 — — — — — CR† — — — 12 9.06 4.0 4.0 2.50 0.82 9.25 10.88 1.0 4.0 1.00 0.22 ≈ 0.41 0.27 3.09 3.0 C, CR #2-14 CU, #2-8 AL CO, COR #2-14 CU ONLY 1.31 COR #1/0-8 CU ONLY CR #1/0-8 CU/AL SR #8W/ Ring Terminal (See Figures) 7.125 Wire Range C, CR #2-14 CU, #2-12 AL CO, COR #6-14 CU ONLY P, PR #10-18 CU ONLY Q N/A S, SR #10-18 CU ONLY 2.06 0.5 2.0 3.0 0.75 — 0.31 CR 250kcmil-6 CU/AL 1 H25600-1 — — — — to 3 H25600-3 — — — — 600 *UL Recognized, CSA Certification. †No UL, No CSA Certification. — CR (See Figures) — — — 10 11.0 4.97 3.0 4.0 1.125 1.75 — CR† — — — 12 11.0 4.97 5.0 3.0 1.87 11.0 — 0.31 — 0.31 CR 500kcmil-4 CU/AL CR (2) 500kcmil-4/0 CU/AL 14.74 1.00 Data Sheet:H250 Series,1112; R250 Series, 1110 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 47 Fuseblocks, Holders and Terminal Blocks Bussmann® Class H(K) and R Fuseblocks – 250V Class R Fuseblocks (250V) Catalog Data (for LPN-RK, FRN-R, DLN-R and KTN-R Fuses) Terminal Type (Suffix No.) 31 to 60 61 to 100 101 to 200 201 to 400 Box Lug w/ Clip — Cu Only CR COR CR COR CR COR Dimensions (Inches) 1 2 3 1 2 3 1 2 3 R25060-1 R25060-2 R25060-3 R25100-1 R25100-2 R25100-3 — — — — — — — — — — — — CR CR CR CR CR CR COR COR COR COR COR COR — — — — — — 4 5 6 7 8 9 1 3 R25200-1 R25200-3 — — — — CR CR — — — — 10 11 7.125 1 R25400-1 — — CR‡ COR‡ — 10 9.06 Poles Amps ⁄Ω¡º to 30 Screw w/ Pres. — Plate SR PR SR PR SR PR Basic Catalog Number R25030-1 R25030-2 R25030-3 3 R25400-3 — — 401 1 R25600-1 — — to 3 R25600-3 — — 600 *UL Recognized, No CSA Certification. †No UL, No CSA Certification. ‡UL Recognized, CSA Certification 0.25⬙ QuickConnect QR* QR* QR* Fig. No. 1 2 3 A B C D E F G H 1.25 — 1.31 1.31 J Dia. x C’ Bore K 0.22 x 0.41 0.27 (See Figures) 4.25 1.73 1.5 2.81 4.125 1.5 0.5 0.5 3.0 2.06 0.5 2.0 COR #2-14 CU ONLY CR #2-14 CU, #2-8 AL COR 1/0-8 CU ONLY CR 1/0-8 CU/AL (See Figures) 3.15 Wire Range COR #6-14 CU ONLY CR #2-14 CU, #2-12 AL PR #10-18 CU ONLY QR N/A SR #10-18 CU ONLY 3.0 0.75 3.0 1.0 — 0.31 — 0.56 — 0.56 CR (2) 500kcmil-4/0 CU/AL CR 250kcmil-6 CU/AL (See Figure) 4.0 3.0 3.02 0.91 1.75 CR† COR† — 12 9.06 4.0 4.0 2.5 0.82 9.25 10.88 1.0 CR CR† — — — — 10 12 11.0 11.0 4.97 4.97 3.0 5.0 4.0 3.0 1.125 1.87 1.75 11.0 4.0 14.74 1.0 1.0 COR 500kcmil-4/0 CU ONLY CR 500kcmil-4 CU/AL CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. Dimensional Data 250V ⁄Ω¡ºA to 30A 1.41" 0.22" 1.09" 0.17" 0.75" 0.41" 2.05" 1.25" 0.95" 0.25" 3" 2.5" 2 SPACES AT 0.95" - 1.91" 1.27" 3.03" 0.5" 1.52" 0.22" DIAMETER FIGURE 1. 0.55" FIGURE 2. 0.55" FIGURE 3. Data Sheet: H250 Series,1112; R250 Series, 1110 48 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Class H(K) and R Fuseblocks – 250V 250V, 31A to 60A C B K F C C H E F F E H H J J J A G D FIGURE 4. FIGURE 5. FIGURE 6. 250V, 61A to 100A 3.38" 1.56" 0.59" 1.81" 2.06" 0.25" 0.62" 0.59" 4.94" 1.56" 1.56" 0.62" 0.62" 0.28" DIA. x 0.5" C'BORE 7.36" 2.38" 3.125" 2.125" FIGURE 7. FIGURE 8. 250V, 101A to 200A 250V, 101A to 600A B H K FIGURE 9. 8" 5" 3.4" G F E 6" 3" .5" 1" 2" 7.13" .34" DIA. HOLE THROUGH 0.34 DIAMETER 0.75" C'BORE 4.5" C A EYELETS TO ACCEPT .25" DIA. SCREW 3" 2.06" D 9" FIGURE 10. FIGURE 11. 250V, 201A to 600A G B F E H A C .34" DIA. HOLE THRU D FIGURE 12. Data Sheet: H250 Series,1112; R250 Series, 1110 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 49 Fuseblocks, Holders and Terminal Blocks Bussmann® Class H(K) and R Fuseblocks – 600V H600 Series For use with Class H Fuses (Bussmann NOS and RES). R600 Series For use with Class R Fuses (Bussmann LPS-RK, FRS-R, DLS-R and KTS-R). Construction: Thermoplastic, UL Flammability: 94VO Ampere Ratings: ⁄Ω¡º-600A Withstand Ratings: H600Series - 10,000A RMS Sym.; R600 Series - 200,000A RMS Sym. Voltage Rating: H600, 600V; R600, 600V Agency Information: UL Listed UL512, Guide IZLT, File E14853; CSA Certified, Class 6225-01, File 47235 Class H Fuseblocks (600V) Catalog Data (for NOS and RES Fuses) 31 to 60 61 to 100 101 to 200 201 Clip with Reinforced Spring Clip w/ Reinforced Spring (Copper Only) Copper Only 0.25∑ Quick Connect 1 3 Pressure Plate & Clip with Reinforced Spring — H60060-1 H60060-2 H60060-3 H60100-1 H60100-2 H60100-3 Pressure Plate 1 2 3 1 2 3 Clip with Reinforced Spring 1 2 3 Basic Catalog Number H60030-1 H60030-2 H60030-3 Poles Amps ⁄Ω¡º to 30 Dimensions (Inches) – See Next Page For Figures — Terminal Type (Suffix No.) Screw Box Lug w/ S S S SR SR SR P P P PR PR PR CR COR CR COR CR COR CO CO CO — — — C C C Fig. No. 1 2 3 — — — — — — — SR‡ — SR‡ — SR‡ — — — — — — — — — — — — C C C — — — CR CR CR CR CR CR COR COR COR COR COR COR CO CO CO — — — — — — — — — 4 5 6 1 2 3 H60200-1 H60200-3 — — — — — — — — — CR — CR — — — — — — 1 H60400-1 — — — — — CR‡ COR‡ — 3 H60400-3 — — — — — CR† — — CR — CR† A B 6.25 1.73 C 1.54 2.90 4.25 D E F G H J Dia. ≈ C’ Bore K 1.56 .25 0.62 3.13 1.56 0.28 ≈ 0.5 .26 C, CR #2-14 CU, #2-8 AL CO, COR #4-14 CU ONLY (See Figures) 9.5 2.38 2.22 4.03 5.84 2.63 0.67 7 8 9.63 3.09 3.0 3.31 0.5 — 7 12.0 4.0 3.0 4.5 0.63 — — 9 — — — — 7 10 0.88 4.25 1.81 0.28 ≈ 0.50 .34 2.0 3.0 (See Figures) 0.75 — 0.31 1.0 — 0.56 1.0 — 1.75 3.0 to 400 401 1 H60600-1 — — to 3 H60600-3 — — 600 †No UL, No CSA Certification. ‡UL Recognized, CSA Certification — — — — — — (See Figures) 14.0 4.97 3.0 5.5 1.125 1.75 4.0 (See Figures) Wire Range C, CR #2-14 CU, #2-12 AL CO, COR #6-14 CU ONLY P, PR, S, SR #10-18 CU ONLY 0.56 COR 1/0-8 CU ONLY CR 1/0-8 CU/AL SR #8w/ Ring Terminal CR 250kcmil-6 CU/AL COR 500kcmil-4/0 CU ONLY CR 500kcmil-4 CU/AL CR 500kcmil-4/0 CU/AL CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: H600 Series, 1113; R600 Series, 1111 50 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 600V Class R Fuseblocks (600V) Catalog Data (for LPS-RK, FRS-R, DLS-R and KTS-R Fuses) Terminal Type (Suffix No.) 1 2 3 1 2 3 1 2 3 Screw w/ Pres. — Plate SR PR SR PR SR PR — — — — — — — — — — — — Box Lug w/ Clip — Cu Only CR COR CR COR CR COR CR COR CR COR CR COR CR COR CR COR CR COR 1 3 R60200-1 R60200-3 — — — — CR CR — — CRQ† — 1 3 R60400-1 R60400-3 — — — — CR‡ CR† COR‡ — — — CR CR† — — Poles Amps ⁄Ω¡º to 30 31 to 60 61 to 100 101 to 200 201 to 400 Dimensions (Inches) Basic Catalog Number R60030-1 R60030-2 R60030-3 R60060-1 R60060-2 R60060-3 R60100-1 R60100-2 R60100-3 401 1 R60600-1 — to 3 R60600-3 — 600 †No UL, No CSA Certification. ‡UL Recognized, CSA Certification 0.25⬙ Quick- Fig. Connect No. — 1 — 2 — 3 — 4 — 5 — 6 — 1 — 2 CRQ† 3 A B 6.25 1.73 C 1.54 2.90 4.25 D E F G H J Dia. x C’ Bore K 1.56 0.25 0.62 3.13 1.56 0.28 x 0.5 .26 COR #2-14 CU ONLY CR #2-14 CU, #2-8 AL (See Figures) 9.5 2.38 2.22 4.03 5.84 2.63 0.67 4.25 1.81 0.28 x 0.5 0.34 7 8 9.63 3.09 3.0 3.31 0.5 2.0 3.0 (See Figures) 0.75 — 0.31 — — 7 9 12.0 4.0 3.0 4.5 0.63 1.75 3.0 (See Figures) 1.0 — 0.56 — — 7 10 14.0 4.97 3.0 5.5 1.125 1.75 4.0 (See Figures) 1.0 — 0.56 0.88 Wire Range COR #6-14 CU ONLY CR #2-14 CU, #2-12 AL PR, SR #10-18 CU ONLY COR 1/0 -8 CU ONLY CR, CRQ 1/0-8 CU/AL CR, CRQ 250kcmil-6 CU/AL COR 500kcmil-4/0 CU ONLY CR 500kcmil-4 CU/AL CR (2) 500kcmil-4/0 CU/AL CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. Dimensional Data 600V, ⁄Ω¡º to 30A and 61A to 100A B K C E F C C H E F F H H J J J A G D FIGURE 1. FIGURE 2. FIGURE 3. Data Sheet: H600 Series, 1113; R600 Series, 1111 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 51 Bussmann® Fuseblocks, Holders and Terminal Blocks Class H(K) and R Fuseblocks – 600V Dimensional Data 600V, 31A to 60A 1.81" 2.06" 0.25" 3.38" 1.56" 0.59" 0.62" 0.59" 4.94" 1.56" 1.56" 0.62" 0.62" 0.28" DIA. x 0.5" C'BORE 7.36" 2.38" 3.125" 2.125" FIGURE 4 E FIGURE 6 600V, 101A to 200A 600V, 101A to 600A B H K FIGURE 5 9.0" 8.0" 6.5" G F 0.34 DIAMETER 3.15" .75" 0.34 DIAMETER 0.75" C'BORE C A 9.58" 0.75" DIA. C'BORE .50" Deep 5.5" 3.0" D 2.04" FIGURE 7 FIGURE 8 600V, 201A to 400A 600V, 401A to 600A 11.63" 9.25" 4.02" 1.00" 1.19" 2.13" 0.34 DIAMETER 0.75" DIA. C'BORE .67" Deep 12.00" 7.00" 15.26" 11.0" 4.987" 1.00" 0.34 DIAMETER 0.75" DIA. C'BORE .67" Deep 14.00" 8.00" 2.5" 2.5" FIGURE 9 FIGURE 10 Data Sheet: H600 Series, 1113; R600 Series, 1111 52 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Class J Fuseblocks J600 Series For use with Class J Fuses (Bussmann® LPJ and JKS). Catalog Symbol: J600 Series Ampere Rating: ⁄Ω™-600A Voltage Rating: 600V Withstand Rating: 200,000 RMS Sym. Amps Agency Information: UL Listed, UL 512, Guide IZLT, File E14853 CSA Certified, C22.2 No. 39, Class 6225-01, File 47235 Materials: Thermoplastic UL Flammability: UL 94V0 Standard J Fuseblocks (600V) Catalog Data Amps Poles Screw† Pressure Plate† 1 2 3 1 2 3 1 3 1 3 1 3 1 3 J60030-1S(2) J60030-2S(2) J60030-3S(2) — — — — — — — — — — — J60030-1P J60030-2P J60030-3P — — — — — — — — — — — ⁄Ω™-30 31-60 61-100 101-200 201-400 401-600 Catalog Numbers Box Box Lug w/ Lug Retaining Clip J60030-1C J60030-2C J60030-3C J60060-1C J60060-2C J60060-3C — — — — — — — — Fig. No. J60030-1CR†† 1 J60030-2CR†† 2 J60030-3CR†† 3 J60060-1CR†† 1 J60060-2CR†† 2 J60060-3CR†† 3 J60100-1CR 4 J60100-3CR†† 5 J60200-1CR 6 J60200-3CR 7 J60400-1CR(3) 8 J60400-3CR(2) 9 J60600-1CR 10 J60600-3CR 11 Wire Range C, CR #2-14 CU, #2-8 AL COR #2-14 CU ONLY P, PR, S, SR #10-14 CU ONLY C, CR, #2-14 CU/AL COR #4-14 CU ONLY COR 1/0-8 CU ONLY CR, CRQ 1/0-8 CU/AL CR 250kcmil-6 CU/AL CR 500kcmil -4 CU/AL CR (2) 500kcmil-4/0 CU/AL †Clip reinforcing springs are standard on fuseblocks rated 100A and above. Available on 30A and 60A blocks by adding the letter “R” to the end of the part number. ††Copper only connections available by changing “CR” suffix to “COR”. (2)No UL, No CSA Certification (3)UL Recognized, CSA Certification CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data All dimensions (±0.015) ⁄Ω™-60A 61-100A 1.702 3.202 .750 2.250 4.702 2.415" 2.250 .750 C L 5" 2.28" .30" 4.005 .94" 1.583" .22" Dia. .5" C'Bore 6.28" CL 3.14" 1.500 1.75" FIGURE 1. FIGURE 2. FIGURE 3. FIGURE 4. 1.5" FIGURE 5. Data Sheet: 1114 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 53 Fuseblocks, Holders and Terminal Blocks Bussmann® Class J Fuseblocks 101-200A 3.1" 3.06" .75" C'Bore 6.125" 7.00" .31" .5" 3.15" 8.31" .75" 3" 2" .344" Dia. hole thru .750 Dia. c'bore 6.125" 1.69" .34" DIA. .750" FIGURE 7. FIGURE 6. 201-400A 10.51" 4" 3" 1.75" .56" .625" 3.5" 7.50" .75" C'Bore .34" DIA. 7.5" 4.00" 9.00" 6.00" 1" .344" Dia. hole thru .750 Dia. c'bore 2.00" .50" .5" 1.00" FIGURE 8. FIGURE 9. 401-600A 4.99" 4" 1.75" 1.125" 4.987" 14.144" 1" 11.00" .56" 3.25" .344" Dia. hole thru .750 Dia. c'bore 8.875" 8.875" 2.375" .75" C'Bore .34" Dia. FIGURE 10. 2.88" FIGURE 11. .50" 1.00" Data Sheet: 1114 54 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Class J Fuseblocks CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information. JP Series For use with Class J Fuses (Bussmann LPJ,JKS). Pyramid Style Fuseblock Ampere Rating: 30A Voltage Rating: 600V Withstand Rating: 200,000 RMS Sym. Amps Agency Information: UL Listed, U.L. 512, Guide IZLT, File E14853 CSA Certified, C22.2 No. 39, Class 4225-04, File 47235 Material: Thermoplastic UL Flammability: UL 94V0 Dimensional Data Pyramid® J Fuseblock; 30A, 600V; 3-Pole; Panel or 35mm DIN-Rail Mount; Clips with Reinforcing Springs Mounting Panel With DIN-Rail Adapter* Screws with Pressure Plate JP60030-3PR (#10-14 CU ONLY) JP60030-3PRA (#10-14 CU ONLY) Catalog Numbers Box Aluminum JP60030-3CR (#2-14 CU/AL) JP60030-3CRA (#2-14 CU/AL) Copper Only JP60030-3COR (#2-14 CU ONLY) JP60030-CORA (#2-14 CU ONLY) *Adapter Only for DIN-Rail - Cat No. JPA-3. *All other dimensions (± 0.015∑) (± 0.40mm) DIN-RAIL MOUNTING SCREW 8" (203.2mm) APART END STOPS - PREVENT BLOCK MOVEMENT WHEN CHANGING FUSES 4.00" MAX. (101.6mm) 2.78" 3.06" 3.75" (±0.02) (70.6mm) (77.8mm) (95.3mm (±0.50) 1.88" (47.6mm) 3.13" (79.5mm) 1.19" ADAPTOR FOR 35mm SYMMETRICAL DIN-RAIL MOUNTING (30.2mm) 2.38" (60.4mm) 3.29" (83.6mm) Data Sheet:1108 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 55 Fuseblocks, Holders and Terminal Blocks Bussmann® Semiconductor Fuseblocks J70100 Amps Ampere Rating: 100A Voltage Rating: 700V Agency Information: UL Recognized, Guide IZLT2, File E14853 Withstand Rating: 200,000 RMS Sym. Amps For use with 22 ≈ 58mm fuses (FWP-40A22F, FWP-100A22F, etc.) Materials: Thermoplastic UL Flammability: UL 94V0 Poles 1 2 3 100 Catalog Numbers Box Lug w/ Fig. Wire Retaining Clip No. Range J70100-1CR 1 #2-14 CU/AL J70100-2CR 2 #2-14 CU/AL J70100-3CR 3 #2-14 CU/AL Dimensional Data 100A 1.702 3.202 .750 2.250 2.415 4.702 2.250 .750 C L 4.005 CL 1.500 FIGURE 1 FIGURE 2 FIGURE 3 Data Sheet: 1211 56 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Class J (Finger-Safe) Fuseholders Safety J JT(N)60030 and JT(N)60060 For use with Bussmann Class “J” fuses - (Bussmann LPJ, JKS) Catalog Numbers: JT60030 and JT60060 - Non-Indicating JTN60030 and JTN60060 - Indicating (Neon) Construction: Thermoplastic, UL Flammability; 94VO Voltage Ratings: 600V Amperage Rating: JT(N)60030 - 30A, JT(N)60060 - 60A Withstand Rating: 200,000A RMS Sym. (Self Certified at 300,000A using Bussmann LPJ_SP fuses) Agency Information: Listed to UL 512: Guide IZLT, File 14853 CSA Certified: Class 6225-01, File 47235 1.14 (29.0) Indication: Min. voltage: 90 VAC, 115 VDC; Neon Lamp “ON” when fuse opens, voltage source and current path are present. Finger-Safe: IP20 per IEC 60529 Terminations: 30A Dual Port Torque 20 lb. in., 60A Single Port Torque 45 lb. in., Terminal Construction, Tin plated Copper Alloy Wire Size: JT(N)60030 - Rated for 75°C, AWG#18-#8; CU only, JT(N)60060 - Rated for 75°C, AWG#14-#4; CU only. (Note: For JT(N)60030 use both stranded or solid, in a variety of dual wire combinations of same wire size and type.) Packaging: 12 in a carton CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 1.05 (26.7) Slot Din-rail .07 (1.8) MOUNTING Shown without fuse pullout cover Dim. = in. (mm.) 2.75 (69.9) 1 pole 2 pole 3 pole BUSS BUSS BUSS JT60030 0 – 30A 600VAC JT60030 0 – 30A 600VAC JT60030 0 – 30A 600VAC USE CLASS J FUSES USE CLASS J FUSES USE CLASS J FUSES DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD 1.23 (31.2) 2.42 (61.3) 3.60 (91.4) 2.52 (64.1) JT60030 JTN60030 Data Sheet: 1152 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 57 Bussmann® Fuseblocks, Holders and Terminal Blocks Class J (Finger-Safe) Fuseholders JT(N)600 Series fuseblocks can be dovetailed together within the same current rating to provide multiple pole block configurations. NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060. 1.31 (33.3) 1.25 (31.8) Slot Din-rail .10 (2.6) 3.10 (78.7) 1 pole 2 pole 3 pole MOUNTING BUSS BUSS BUSS JT60060 35 – 60A 600VAC JT60060 35 – 60A 600VAC JT60060 35 – 60A 600VAC USE CLASS J FUSES USE CLASS J FUSES USE CLASS J FUSES DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD DO NOT REMOVE UNDER LOAD 1.52 (38.1) 2.96 (75.2) 4.40 (111.7) Shown without fuse pullout cover Dim. = in. (mm.) JT60060 JTN60060 3.06 (77.7) Data Sheet: 1152 58 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Class T Fuseblocks – 300V T300 Class T Fuseblocks (300V) Catalog Data (300V) For use with Class T Fuses (Bussmann JJN) Construction: Glass Polyester, Phenolic on 600A, UL Flammability: 94VO Rating: ⁄Ω™-600A Withstand Rating: 200,000A RMS Sym. Agency Information: UL Listed UL512, Guide IZLT, File E14853 CSA Certified, Class 6225-01, File 47235. Catalog Numbers Screw Box Lug 2 T30030-2SR T30030-2CR 3 T30030-3SR T30030-3CR 4 T30030-4SR T30030-4CR 2 T30060-2SR T30060-2CR 3 T30060-3SR T30060-3CR 4 T30060-4SR T30060-4CR 1 — T30100-1CR 2 — T30100-2CR 3 — T30100-3CR 1 — T30200-1C 3 3 — T30200-3C 4 201-400 1 — T30400-1C 5 401-600 1 — T30600-1C 6 (2) 600kcmil-4/0 CU-AL Amps Poles ⁄Ω™-30 31-60 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 61-100 101-200 Dimensional Data Figure 1. ⁄Ω™A to 60A 1.63" 0.72" 0.16" 0.69" 0.91" X 1 1 2 Wire Range SR #10-18 CU CR #6-14 CU-AL CR #2-14 CU-AL SR #10-18 CU ONLY 1/0-8 CU-AL 250kcmil-6 CU-AL 600kcmil-2/0 CU-AL 1.63" 0.72" 0.16" A B 1.20" Fig. No. Z 0.91" 2.75" 2.5" T30030-S SECTION X-X X Z 0.44" Full Radius 0.20" C T30060-C SECTION Z-Z Class T Fuseblocks (300V) Catalog Numbers Dimensions (Inches) Block Type A B C T30030-2 T30060-2 2.41 — 1.03 T30030-3 T30060-3 3.44 1.03 2.06 T30030-4 T30060-4 4.47 2.06 3.09 Data Sheet: 1115 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 59 Fuseblocks, Holders and Terminal Blocks Bussmann® Class T Fuseblocks – 300V Figure 2. 61A to 100A Figure 3. 101A to 200A 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 2.06" 0.84" 6" 1.41" (2 POLE) 2.81" (3 POLE) X 0.05" 3" 1.125" Z 1.25" 2.25" 0.22" DIA. 2.25" REF. 4.78" 1.69" 0.52" C'BORE 0.55" DEEP 2.39" 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 3.06" 2.56" 1.94" 0.81" Z X 0.38" 0.75" Figure 5. 201A to 400A Figure 4. 200A 4.87" 6" 1.695" 3" .996" 2.25" 1.25" 1.125" 0.63" A 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 2.75" A 1.84" 0.282" DIAMETER THRU HOLE 0.625" C'BORE 0.438" DEEP 3.06" 2.38" 2.375" 0.81" 0.625" 4.46" Figure 6. 401A to 600A 2.03" 5.75" 2.88" 1.5" 3.44" 2" 3" 3" 0.75" 0.33" DIAMETER 0.75" C'BORE 0.5" DEEP Data Sheet: 1115 60 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Class T Fuseblocks – 600V Class T Fuseblocks (600V) Catalog Data T600 (600V) For use with Class T Fuses (Bussmann JJS) Construction: Glass Polyester, Phenolic on 600A, UL Flammability: 94VO Rating: ⁄Ω™-600A Withstand Rating: 200,000A RMS Sym. Agency Information: UL Listed UL512, Guide IZLT, File E14853 CSA Certified, Class 6225-01, File 47235. Catalog Numbers Screw Box Lug 1 T60030-1SR T60030-1CR 2 T60030-2SR T60030-2CR 3 T60030-3SR T60030-3CR 1 T60060-1SR T60060-1CR 2 T60060-2SR T60060-2CR 3 T60060-3SR T60060-3CR 1 — 2 — T60100-2C 3 — T60100-3C 1 — T60200-1C 3 — 1B0089* 201-400 1 — 401-600 1 — Amps Poles ⁄Ω™-30 31-60 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 61-100 101-200 1 2 Wire Range SR #10-18 CU CR #2-14 CU-AL CR #2-14 CU-AL SR #10-18 CU ONLY T60100-1C 3 2/0-14 CU-AL 4 250kcmil-6 CU-AL T60400-1C 5 600kcmil-2/0 CU-AL T60600-1C 6 (2) 600kcmil-4/0 CU-AL * UL Listed, Guide IZLT, File E14853, CSA Certified Class 6225-01, File 21455M18 Figure 1. ⁄Ω™A to 30A 1.44" 0.55" 0.5" Fig. No. 1.44" 0.33" 0.55" 2.59" 1.16" 0.33" 0.55" 3.75" 2.31" 0.33" 0.22" DIAMETER 0.5" C'BORE 0.33" 3.19" 1.563" 1.42" Figure 2. 31A to 60A 1.75" 0.59" 0.5" 1.81" 0.63" 0.59" 3.34" 1.53" 0.63" 0.59" 4.86" 3.06" 0.63" 0.22" DIAMETER 0.5" C'BORE 2.94" 1.63" 1.47" Data Sheet: 1116 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 61 Bussmann® Fuseblocks, Holders and Terminal Blocks Class T Fuseblocks – 600V Figure 3. 61A to 100A 1.69" (1 POLE) 3.09" (2 POLE) 4.5" (3 POLE) 1.41" (2 POLE) 2.81" (3 POLE) 0.84" X 0.78" Z 0.22" DIA. 0.52" C'BORE 0.55" DEEP 2.34" REF. 2.39" Z X 0.38" SECTION Z-Z 0.75" Figure 4. 101A to 200A Figure 5. 201A to 400A 6" 0.05" 6" 3" 3" 1.125" 1.25" 2.25" 2.25" 1.25" 1.125" 2.5" 0.63" 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 0.28" DIAMETER 0.63" C'BORE 0.5" DEEP 2.72" 3.06" 2.56" 1.94" 0.81" 3.06" 2.38" 0.81" Figure 6. 401A to 600A 2.95" 6.75" 3.38" 1.5" 3.44" 2" 3" 3" 0.75" 0.33" DIAMETER 0.75" C'BORE 0.5" DEEP Data Sheet: 1116 62 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Class H(K), J and R Fuseblocks Porcelain Type Fuseblocks Modular Type Fuseblocks Class H(K) and R Dimensions Agency Information: UL Listed, Guide IZLT, File E14853 Class H & J Fuses Reinforced retaining clips standard Available in 30A and 60A, 3-pole models only. Agency Information: UL Recognized, Guide IZLT2, File E14853 CSA Certified, Class 6225-01, File 47235 Class H and K Dimension Fuseblocks - Porcelain Type Fuseblocks Terminal Type Volts 250 Amps Poles Screw Box Lug ⁄Ω¡º 1 2601 — to 2 2604 — 30 3 2607 — 31 1 — 2602 to 2 — 2605 60 3 — 2608 600 Fuse Type Volts Amps 250 60 H ⁄Ω¡º to Modular Type For Class H & J Fuses 1 2610 31 to 1 — 2611 60 J 600 Figure Number 11241-3SR 11241-3PR 1 11242-3SR 11242-3PR 2 11241-3SR 11241-3PR 1 11242-3PR 2 11239-3SR 11239-3PR 1 11240-3SR 11240-3PR 2 30 11241-3SR 11241-3PR 1 60 11239-3SR 11239-3PR 1 60 30 Pressure 11242-3SR 30 600 — Catalog Number Screw Note: Order two blocks per fuse (matched or mixed.) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Figure 1 Figure 2 Notes: 1. 11239 and 11241 have wire terminals and mounting holes located under fuse. (Figure 1) 2. 11240 and 11242 have wire terminals and mounting holes located at end of fuse. (Figure 2) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 63 Bussmann® Fuseblocks, Holders and Terminal Blocks Class CC, Type M and Class G Fuseblocks BC Series BM Series Class CC Fuseblocks For use with Class CC Fuses (Bussmann LP-CC, KTK-R, and FNQ-R) Construction: Base - Thermoplastic Clips - Bright tin-plated bronze Ratings: 600V, 30A Withstand Rating: 200,000A RMS Sym. Agency Information: UL Listed (Guide IZLT, File E14853) CSA (Class 6225-01, File 47235) UL Flammability: 94VO Dimensional Data: See Data Sheet. DIN-RAIL Adaptors: Page 200 DRA-1 & DRA-2 Type M Supplementary Fuseblocks For use with any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses (Bussmann KTK, FNQ, FNM, BAF, BAN, and AGU) Construction: Thermoplastic Ratings: 600V, 30A Withstand Rating: 10,000A RMS Sym. Agency Information: UL Recognized (Guide IZLT2, File E14853) CSA (Class 6225-01, File 47235) UL Flammability: 94VO Dimensional Data: See Data Sheet. DIN-RAIL Adaptors: Page 200 DRA-1 & DRA-2 Poles Terminal Type Screw Pressure with Plate w/ Quick Pressure Quick Box Screw Connect* Plate Connect* Lug Amps Poles Terminal Type Screw Pressure with Plate w/ Quick Quick Connect* Connect* ⁄Ω¡ º 1 BC6031S BC6031SQ BC6031P BC6031PQ BC6031B ⁄Ω¡ º 1 BM6031SQ BM6031PQ BM6031B to 2 BC6032S BC6032SQ BC6032P BC6032PQ BC6032B to 2 BM6032SQ BM6032PQ BM6032B 30 3 BC6033S BC6033SQ BC6033P BC6033PQ BC6033B 30 3 BM6033SQ BM6033PQ BM6033B CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1105 BCCM Series For use with (2) Class CC Fuses and (1) ⁄‹Ω£™⬙ x 1⁄Ω™⬙ Fuse. Catalog Data Terminal Type Screw with Quick Connect* BCCM6033SQ Pressure Plate w/Quick Connect* BCCM6033PQ *Quick connect terminal rated for 20A max. Data Sheet: 1106 64 Class G Fuseblocks For use with Class G Fuses (Bussmann SC) Construction: (0-30) Thermoplastic (35-60) Phenolic Ratings: 600V, 0-20A 480V, 25-60A Withstand Rating: 100,000A RMS Sym. Agency Information: UL Listed 35-60A (Guide IZLT, File E14853) UL Recognized 1-30A, (Guide IZLT2, File E14853) CSA (Class 6225-01, File 47235) Dimensional Data: See Data Sheet. DIN-RAIL Adaptors: Page 200 DRA-1 & DRA-2 Catalog Data Catalog Data Amps BG Series and G Series Catalog Data Box Lug CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1104 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Terminal Type Screw Pressure with Plate w/ Quick Quick Amps Poles Connect* Connect* Box Lug Box Lug w/retaining clip 1 1 BG3011SQ BG3011PQ BG3011B — to 2 BG3012SQ BG3012PQ BG3012B — 15 3 BG3013SQ BG3013PQ BG3013B — 1 BG3021SQ BG3021PQ BG3021B — 20 2 BG3022SQ BG3022PQ BG3022B — 3 BG3023SQ BG3023PQ BG3023B — 25 1 BG3031S BG3031P BG3031B — to 2 BG3032S BG3032P BG3032B — 30 3 BG3033S BG3033P BG3033B — 35 1 — — — G30060-1CR to 2 — — — G30060-2CR 60 3 — — G30060-3C G30060-3CR CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1106 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Modular Fuseholders CH Series Features: • 10 ≈ 38 Dovetail design provides maximum flexibility in assembling multiple poles • Touchsafe design - No exposed contacts • DIN rail mount (35mm) • Optional open fuse indication lights • Excellent for switchboard panel, control consoles, small motors, transformers, and similar applications • Handle/fusepuller to install and remove fuses easily • Available in single and multi-pole configurations • Circuit marking system (P/N CH10CL and CH10CM) • Wire ready: Saves time as terminals are ready to accept wires. • CE marking Standards: North American Class CC Listed UL 512, Guide IZLT, File E14853 Certified CSA Std. C22.2 No. 39, Class 6225-01, File LR47235 North American Midget ⁄‹Ω£ ™∑ x 1 ⁄Ω™∑ UL Recognized 512, Guide IZLT2, File E14853 CSA Certified, Std. C22.2 No. 39, Class 6225-01, File LR47235 European 10 ≈ 38 IEC 269-2-1 14 ≈ 51 IEC 269-2 UL Recognized, CSA Certified*** 22 ≈ 58 IEC 269-2 UL Recognized, CSA Certified*** Recommended Buss® Fuse Types: North American Class CC Fuses - LP-CC, FNQ-R, KTK-R North American Midget Fuses - FNQ, KTK, AGU, KLM, BAF, BAN, FNM, FWA, FWC, & FNQ 10 ≈ 38 European Fuses - C10M, C10G 14 ≈ 51 Fuses - FWX, FWH, FWP, NON, C14M, C14G 22 ≈ 58 Fuses - FWP, C22M, C22G Specifications Fuse Size (mm) Voltage UL/CSA IEC UL/CSA IEC Amperage Wire Size Wire Type (& Temp.) Torque (in-lbs) IP Rating Contact Material (fuseclip) Connector Material Maximum Watts Loss of Fuse Dual Wire Rating 10 ≈ 38 Description 1 Pole 1 Pole w/Indication 2 Pole 2 Pole w/Indication 3 Pole 3 Pole w/Indication *Assembly Pins - 2 Poles *Assembly Pins - 3 Poles **Circuit markers **Circuit marker labels Spare Fuseholder 30A, 600V North American Class CC Fuseholder CHCC1 CHCC1I CHCC2 CHCC2I CHCC3 CHCC3I CH102AP CH103AP CH10CM CH10CL 5TPH 10 ≈ 38 600V 690V 30A 32A (See Watts Loss) #8 - #18 CU only Solid/Stranded (75°) 12 in-lbs IP 20 Tin-plated copper Steel 3W‡ Please consult factory 30A, 600V North American Midget Fuseholder CHM1 CHM1I CHM2 CHM2I CHM3 CHM3I CH102AP CH103AP CH10CM CH10CL 5TPH 32A, 690V European 10 ≈ 38 Fuseholder CH101 CH101I CH102 CH102I CH103 CH103I CH102AP CH103AP CH10CM CH10CL 5TPH ‡Refer to Data Sheets 720003, 720008, 720025 and 720028 for watts loss of applicable fuses. *CH102AP and CH103AP are packaged in quantities of ten pins. One pin is required to gang units together, and rating multiple poles. **CH10CM are packaged in quantities of ten. CH10CL are packaged in quantities of ten sheets of labels. ***UL/CSA part numbers include U.L. suffix. (i.e. -14x51 with UL rating is CH141GUL for a single pole device) 14 ≈ 51 750V*** 660V 30A*** 50A (See Watts Loss) #6 - #14 CU only Solid/Stranded (75°) 17.7 in-lbs IP 20 Tin-plated copper Steel 5W‡ Description 1 Pole 1 Pole w/UL markings 1 Pole w/microswitch 2 Pole 3 Pole 3 Pole w/microswitch Handle Profile - 2 Poles Handle Profile - 3 Poles 22 ≈ 58 750V*** 660V 50A*** 125A (See Watts Loss) #1 - #14 CU only Solid/Stranded (75°) 22.1 in-lbs IP 20 Tin-plated copper Steel 9.5W‡ 14 ≈ 51 Part No. Ctn. Qty. CH141G 6 CH141GUL 6 CH141MSG 6 CH142G 3 CH143G 2 CH143MSG 2 CH142HCG 10 CH143HCG 10 22 ≈ 58 Part No. Ctn. Qty. CH221G 6 CH221GUL 6 CH221MSG 6 CH222G 3 CH223G 2 CH223MSG 2 CH222HCG 10 CH223HCG 10 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1151 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 65 Fuseblocks, Holders and Terminal Blocks Bussmann® For ⁄‹Ω£™∑ ≈ 1⁄Ω™ ∑ Fuses 3743 4421 and 4515 Add-on Fuseblocks for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Fuses UL Recognized Guide IZLT2, File E14853 Block with One Pole. Single pole blocks lock into each other and can be added at any time. Each has a single end barrier. Molded phenolic base; screw terminal; beryllium copper, bright-dipped clips. Rated 30A, 600V. Single Pole Fuseblocks for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Fuses Electrical Ratings: 30A, 250Vac (or less) 3835 Series Multiple Pole Fuseblocks for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Fuses No. 4421—Solder Terminals. Base width fiΩ•∑ (15.9mm). 2.5" No. 3742—End Barrier Only. Silver-plated, beryllium copper clips. Rated 30A, 250V. No side barriers. Screw terminals. Phenolic base. (63.5mm) 0.897" 0.19" (22.78mm)(4.8mm) 1.63" (41.3mm) 3835-1 No of Poles 1 Base Length Inches mm ¤‡Ω£™∑ 21.4 3835-2 2 1⁄‹Ω¡§∑ 46.0 3835-3 3 2¤fiΩ£™∑ 70.6 3835-4 4 3‹Ω¢∑ 95.2 3835-5 5 4¤‹Ω£™∑ 119.9 3835-6 6 5⁄⁄Ω¡§∑ 144.5 3835-7 7 6¤⁄Ω£™∑ 169.0 3835-8 8 7fiΩ•∑ 193.7 3835-9 9 8⁄·Ω£™∑ 218.8 3835-10 10 9·Ω¡§∑ 242.9 3835-12 12 11⁄Ω™∑ 292.1 Cat. No. 0.84" 3742 2.56" 1.125" 0.25" No. 3723—Marking Strip. Length is 9‹Ω•∑ (23.8cm). Block and end barrier. *Base width — 2‹Ω¢∑ (69.9mm) 2.75" (69.9mm) 2.56" 2.56" (65.1mm) 0.897" 1.29" 0.500" BUSS No. 4515—Screw Terminals. Base width ‹Ω¢∑ (19mm). 0.19" (22.78mm) (4.8mm) Note—Mounting screw hole diameter is 0.147∑ (3.7mm). Countersink, 0.312∑ (7.9mm). Max. Mounting Screw No. 6. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 0.323" (65.1mm) (8.2mm) 1.0" 0.25" 1.125" 0.25" (25.4mm) (6.4mm) (6.4mm) (28.6mm) 0.78" (19.8mm) 0.144" 1.34" (34.1mm) Note—Mounting screw hole diameter is 0.147∑ (3.7mm). Counterbore diameter, 0.636∑ (8.0mm) Max. Mounting Screw No. 6. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Note—Mounting screw hole diameter is 0.148∑ (3.7mm). Countersink, 0.313∑ (7.9mm). Max. Mounting Screw No. 6. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2104 66 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Modular Fuseblocks BH Series For use with Bussmann semiconductor fuses. Base: Light weight, high temperature thermoplastic Mounting Studs: Plated steel Nut: Plated steel Washer: Spring steel Agency Information: UL Recognized, Guide EZLT2, File No. E14853 up to 700V CSA Certified, Class 6225-01, File No. 47235 up to 700V Withstand Rating: 200,000A RMS Sym., or interrupting rating of the fuse used, whichever is smaller. Available Part Numbers CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. BH-0001 BH-1001 BH-2001 BH-3004 BH-0002 BH-1002 BH-2002 BH-3033 BH-0003 BH-1003 BH-2003 BH-3144 BH-0111 BH-1131 BH-2031 BH-3145 BH-0112 BH-1132 BH-2032 BH-0113 BH-1133 BH-0121 BH-2033 BH-3003 BH-0122 Data Sheet: (BH-0) 1200; (BH-1) 1201; (BH-2) 1202; (BH-3) 1203 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 67 Bussmann® Fuseblocks, Holders and Terminal Blocks Box Cover Units for Plug Fuses BOX COVER UNITS SOU, SRU, SSU, SOW, SRW, SSW, SOX, SRX, SSX, SOY, SRY, SSY, SSY-RL, SSY-L, STY, SCY, SOY-B & SKA • Plug-fuse Box Cover Units provide a simple inexpensive way to protect small motors with Buss dual-element FUSETRON Type T or FUSTAT Type S plug fuses. • Box Cover Units are easily installed in standard electric boxes. • Using fuses sized at the ampere rating of a motor or slightly larger, will provide optimum overload and shortcircuit protection. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Selection Data - Plug Fuse Box Cover Units Box Cover Cat. No. SOU _________ SRU _________ Receptacle Outlet to Load Fuseholder Type Box 2⁄Ω¢∑ Handy Single Double 125V 250V Switch Control1 Switch Light2 Motor Size (Max.) General Data Agency4 Listing/ Certification X ‹Ω¢ HP 125V, 15A UL, CSA ____ ___________________________________________________________________________________________________________________ X X ⁄Ω™ HP 125V, 15A UL ___________________________________________________________________________________________________________________ ____ 5 X X ⁄Ω™ HP 125Vac, (do not use on dc), 15A UL, CSA SSU _____________________________________________________________________________________________________________________________________ ____________ _ SOW X ‹Ω ¢ HP 125V, 15A UL, CSA ____ _________ ___________________________________________________________________________________________________________________ SRW 2‹Ω¢∑ Switch X X ⁄Ω™ HP 125V, 15A UL _________ __________________________________________________________________________________________________________ ____________ _ SSW X X ⁄Ω ™ HP 125Vac, (do not use on dc), 15A UL, CSA _________________________________________________________________________________________________________________________________________________ _ SOX _________ SRX _________ 4∑ Octagon X ‹Ω¢ HP 125V, 15A UL, CSA ____ ___________________________________________________________________________________________________________________ X X ⁄Ω™ HP 125V, 15A UL ___________________________________________________________________________________________________________________ ____ SSX X X ⁄Ω™ HP 125Vac, (do not use on dc), 15A UL, CSA _____________________________________________________________________________________________________________________________________ ____________ _ SOY X ‹Ω¢ HP 125V, 15A UL, CSA ____ _________ ___________________________________________________________________________________________________________________ SRY _________ SSY _________ SSY-RL _________ STY3 _________ X X ⁄Ω™ HP 125V, 15A UL ___________________________________________________________________________________________________________________ ____ X X ⁄Ω™ HP 125Vac, (do not use on dc), 15A UL, CSA ____ ___________________________________________________________________________________________________________________ 4∑ Square X X X X ⁄Ω™ HP 125Vac, (do not use on dc), 15A — ___________________________________________________________________________________________________________________ ____ X X ⁄Ω™ HP 125Vac, (do not use on dc), 15A UL ___________________________________________________________________________________________________________________ ____ 125Vac, (do not use on dc), SCY X X(2) ⁄Ω™ HP (2) UL can protect two motors, 15A _________ ___________________________________________________________________________________________________________________ ____ SOY-B X ‹Ω¢ HP 125V, protects two motors, 15A UL _____________________________________________________________________________________________________________________________________ ____________ _ SKA 4⁄⁄Ω¡§∑ Square X X(15A) 2 HP 250V, 15A single phase UL _____________________________________________________________________________________________________________________________________ ____________ 1Switch turns power to fused load OFF or ON. 2Switch light indicates power to load (dark when switch OFF or fuse open). 3Double-pole switch opens both side of circuit. STY can be used for two separate 125V motors not larger than 1/2 HP with the common switch, or a single motor not larger than 2 HP at 250V (Maximum of 150V to ground). 4UL Guide JAMZ, File IE6491; CSA Class 6225-01, File 47235. 5Weatherproof version available, Part No. SSN. Data Sheet: 1129 68 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Printed Circuit Board Mount for 5mm ≈ 20mm Fuses HTC-45M HTC-50M HTC-60M, HTC-65M PCB Vertical Mount 250V, 6.3A, 2.5W Bayonet Cap/Carrier See specifications below PCB Horizontal Mount 250V, 6.3A, 2.5W Bayonet Cap/Carrier See specifications below 250V, 6.3A Body Material: Valox DR48 Terminals: Phosphor bronze 1.303" Mounting Holes (33.1mm) 1.303" (33.1mm) HTC-60M (2 Legs) .102" Dia. Hole (2.6mm) .051" Dia. Hole .051" _+ .002" Dia. (Typ.) ( 1.30 _+ .05mm) Printed Circuit Board (9.0mm) .394" (10.0mm) ( 1.30 _+ .05mm) (1.3mm) .354" .394" _ .002" Dia. (Typ.) .051" + .591" (15.0mm) Mounting Holes Printed Circuit Board .512" (10.0mm) (13.0mm) .138" .512" .512" (3.5mm) (13.0mm) (13.0mm) HTC-65M (4 Legs) S FU E S FU E .197" .591" (5.0mm) (15.0mm) .461" .461" (11.7mm) (11.7mm) .102" Dia. Hole (2.6mm) .051" Dia. Hole (1.3mm) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. .886" .354" (22.5mm) (9.0mm) .551" (14.0mm) .138" (3.5mm) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2110 Data Sheet: 2110 Data Sheet: 2110 Specifications Terminals: Molded Materials: For HTC-45M, HTC-50M Tin-plated. High temperature thermoplastic that meets the flammability ratings of UL 94VO; Glow Wire Test: 960°C per IEC 695-2-1. Solderability: In accordance with IEC 68-2-20. Electrical: Contact Resistance: ≤ 10mΩ; Insulation Resistance: ≥ 10mΩ; Dielectric Strength ≥ 2000 Vac. Shock Safety: PC2 (fuseholders). Agency Information: HTC-45M, HTC-50M UL Recognized, (Guide IZLT2, File E14853; 6.3A, 250V; CSA Certified, (Class 6225-01, File 47235; 6.3A, 250V) SEMKO: (9226032; 6.3A, 250V). Packaging: Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/). For complete specification data, call Bussmann Information Fax ~ 636.527.1450 69 Fuseblocks, Holders and Terminal Blocks Bussmann® PC Board Mount for 5mm ≈ 20mm and ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fuses HBH-I (for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ fuses) HBH-M (for 5mm ≈ 20mm fuses) HBV-I (for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ fuses) HBV-M (for 5mm ≈ 20mm fuses) HBW-I (for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ fuses) HBW-M (for 5mm ≈ 20mm fuses) Horizontal Mount Vertical Mount with Stability Pins Vertical Mount without Stability Pins 0.510" 0.510" 0.437" (11.1mm) 1.77" (45.0mm) 0.480" (12.2mm) (13.0mm) 1.855" 1.855" (47.0mm) 0.490" (47.0mm) HBW HBV (13.0mm) 0.040" (12.4mm) (1.05mm) 0.040" (1.05mm) 0.197" (5.0mm) 0.244" 0.040" (1.0mm) (6.2mm) 0.580" (14.9mm) 0.140" 0.580" (3.5mm) (14.9mm) 0.200" (5.0mm) 0.469" (12.0mm) 0.050" Dia. 3 Holes (1.3mm) 0.100" Dia. 4 Holes (2.54mm) 0.600" 0.700" 0.250" 0.531" (15.2mm) 0.531" (13.5mm) (13.5mm) (17.8mm) 0.400" (6.4mm) Panel 0.200" (5.0mm) 0.050" Dia. 2 Holes (10.0mm) 0.050" Dia. 2 Holes (1.3mm) (1.3mm) PC Board Panel Data Sheet: 2118 PC Board Panel Data Sheet: 2118 0.400" (10.0mm) PC Board Data Sheet: 2118 Fuseholder Caps (Fit all three shown above) FBI Specifications Electrical Ratings: Molded Material: Fuse Carrier & Knob: Mounting: Environmental: Agency Information: FBM UL — 16A @ 250V; CSA — 12A @ 250V; VDE — 6.3A @ 250V; SEMKO — 10A @ 250V Insulation resistance — 10,000 megohm at 500Vdc. Contact resistance — less than 0.005 ohms @ 20mV. Dielectric strength — over 200V/mil. High dielectric molded phenolic with a UL 94VO flammability rating. Spring-loaded, bayonet type. Tin plated brass. Screwdriver slotted. “Kicked” terminals (all models) and stabilizer pins on HBV model for increased stability. Maximum operating temperature — (-40°C to +85°C). UL Recognized — Guide IZLT2, File EI4853; CSA Certified — Class 6225-01, File 47235 VDE — 41421 SEMKO — 9308147 (HBH, HBV) 9222106 (HBW) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 70 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Panel Mounted for 5mm ≈ 20mm Fuses HTC-30M 34.2mm 1.8mm 13.0mm Ø16mm Ratings: 250V, 6.3A, 2.5W Screwdriver slot 14.00mm 3.0x0.51mm Ø16mm 4mm 6.8mm Data Sheet: 2110 11mm HTC-35M 37.5mm 12.00mm +0.0 –0.1 3.0x0.51mm Ø15mm 12.70mm +0.0 –0.1 Ø16mm Ratings: 250V, 6.3A, 2.5W Threaded cap 4mm 5.5mm HTC-40M Data Sheet: 2110 11mm 12.00mm +0.0 –0.1 12.70mm +0.0 –0.1 3.0x0.51mm Ø15mm Ø22mm 37.5mm Ratings: 250V, 6.3A, 2.5W Screwdriver slot 6.5mm Data Sheet: 2110 HTC-55M 36mm 12.70mm +0.0 –0.1 Ø15mm 0.5mm 4mm 5.5mm 11mm 35.5mm HTC-70M 10.2mm 12.00mm +0.0 –0.1 Ø16mm 4.8x0.51mm Ø15mm Ratings: 250V, 10A, 2.5W Fuse carrier: bayonet type Data Sheet: 2110 0.5mm 4mm 5.5mm 11mm 12.70mm +0.0 –0.1 Ratings: 250V, 6.3A, 2.5W Fuse carrier: bayonet type 12.00mm +0.0 –0.1 3.0x0.51mm Ø16mm Data Sheet: 2110 Specifications Terminals: Molded Materials: Brass, tin-plated. High temperature thermoplastic that meets the flammability ratings of UL 94VO; Glow Wire Test: 960°C per IEC 695-2-1. Solderability: In accordance with IEC 68-2-20. Agency Information: UL Recognized — Guide IZLT2, File E14853; CSA Certified — Class 6225-01, File 47235; SEMKO — 9226031 (HTC-30M, HTC-35M); 9226032 (HTC-40M); 9226033 (HTC-55M); 9226034 (HTC-70M) Electrical: Contact Resistance: ≤ 10mΩ; Insulation Resistance: ≥ 10mΩ; Dielectric Strength ≥ 2000 Vac. Shock Safety: PC2 (fuseholders). Packaging: Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/). CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 71 Fuseblocks, Holders and Terminal Blocks Bussmann® Panel Mounted for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses HKP, HKP-L, HKP-W Standard Fuseholders HKP-BBHH, HKP-HH and HKP-LW-HH HKP-OO Snap-Lock Fuseholders Fuseholders with ⁄/¢∑ Quickconnects Electrical Ratings for HPF Series Electrical Ratings for HPF Series Electrical Ratings for HPF Series Catalog Symbol Amps Volts Fuse Description Catalog Symbol Catalog Symbol HKP 30 250 — HKP-BBHH 15 HKP-L 30 250 HKP with 2250V stand-off barrier. HKP-HH 15 250 HKP with ⁄Ω¢∑ quick-connect. HKP-W 30 250 HKP with drip-proof knob. HKP-LW-HH 15 250 HKP with drip-proof knob, 2250V stand-off barrier and quick-connects. Amps Volts 2.31" Fuse Description 250 HKP with ⁄Ω¢∑ quick connects, nut and washer assembled. .75" 0.463" REF. 0.69" F E FU SE US FUSE E US FU HKP with snap-lock. (19.1mm) 0.69" (17.5mm) Fuse Description 2.64" (19.1mm) 0.69" 250 1.56" (39.7mm) 2.44" 0.75" F 30 WHEN FUSE IS INSERTED (58.7mm) SE Amps Volts HKP-OO .855" (21.7mm) 1.17" FUSE .800" (20.3mm) Punched Mounting Hole Punched Mounting Hole Drilled Mounting Hole #41 DRILL 0.5" DRILL .505" + .005" Punched Mounting Hole .890" (22.6mm) .505" + .005" (12.8mm + .13mm) (12.8mm + .13mm) .473" + .005" .473" + .005" (12.0mm + .13mm) (12.0mm + .13mm) Data Sheet: 2106 0.27" .811" (20.6mm) Data Sheet: 2106 Data Sheet: 2106 Specifications Terminals: Bayonet-type knob. Vibration resistant. For panels up to fiΩ¡§∑ (7.9mm) thick. Agency Information: UL Recognized — Guide IZLT2, File E14853 CSA Certified — Class 6225-01, File 47235 Replacement Parts: Knob: 9435-⁄/™∑ Plastic Nut: BK/1A4287 Metal Nut: BK/1A4806-2 Washer: 9732 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 72 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Panel Mounted for 5mm ≈ 20mm and ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses HTB Series Fuseholders with Knob-Type Carriers Agency Information: UL Recognized — Guide IZLT2, File E14853 20A (‹Ω¡ §⬙ quick-connect 15A) @ 250V CSA — 16A @ 250V Class 6225-01 File 47235; VDE* — 6.3A @ 250V, 49890 SEMKO* — 6.3A @ 250V, 8945092, 9005230 *Screwdriver slot carrier only Electrical Data: Insulation resistance (per IEC #257) — 10,000 ohms @ 500Vdc; contact resistance (per IEC #257) — 0.005 ohms max. @ 1A; standoff voltage (per IEC #257) — 480V/Mil @ .125 in. thickness. Environmental: Maximum operating temperature -55°C to 85°C. Molded Components: High temperature, flame retardant, thermoplastic; UL Component Recognized; 94VO; mounting nut, spacer-black polycarbonate. Terminals: Tin-plated brass. Mounting: Withstands 15 to 20 lbs-ins torque to mounting nut when mounting fuseholder to panel. Maximum panel thickness 0.300 inches. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data Terminal Options Knob Type Carrier Solder/ ‹Ω¡ §∑ Quick-Connect Common Dimensional Data: Length (Knob Type) - 1.69∑ (42.9mm) Plus In-Line Terminal (Screwdriver Slotted) 1.75∑ (44.5mm) NOTE: Plus In-Line Terminal 0.47" 1.125" (11.9mm) (28.6mm) Maximum Panel Thickness In-Line Rt. Angle Carrier Options ⁄Ω¢∑ Quick-Connect In-Line Rt. Angle Knob 0.34" 0.33" (8.7mm) (8.3mm) 0.47" (11.9mm) 0.09" NOM. (2.4mm) 0.69" 0.91" (17.5mm) (23.0mm) 5mm x 20mm (“M” Equals Metric) Knob 0.45" (11.5mm) HTB-22I HTB-24I HTB-26I HTB-28I ✓ — HTB-22M HTB-24M HTB-26M HTB-28M — ✓ HTB-42I HTB-44I HTB-46I HTB-48I ✓ — HTB-42M HTB-44M HTB-46M HTB-48M — ✓ HTB-62I HTB-64I HTB-66I HTB-68I ✓ — HTB-62M HTB-64M HTB-66M HTB-68M — ✓ HTB-82I HTB-84I HTB-86I HTB-88I ✓ — HTB-82M HTB-84M HTB-86M HTB-88M — ✓ 0.30∑ 7.62mm Low Profile Rear Hex Nut ⁄Ω¢∑ x 1⁄Ω¢∑ (“I” Equals Inches) HTB-2 0.125∑ 3.18mm High Profile Rear Hex Nut HTB-4 0.67" 0.92" (17.1mm) (23.4mm) 0.30∑ 7.62mm Front Hex Nut HTB-6 0.47" 1.125" (11.9mm) (28.6mm) 0.125∑ 3.18mm Low Profile Snap-In HTB-8 Fuseholders and fuse carriers may be ordered separately. Data Sheet: 2119 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 73 Bussmann® Fuseblocks, Holders and Terminal Blocks Panel Mounted for 5mm ≈ 20mm and ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses HTB Series Fuseholders with Screwdriver Slotted Carriers Dimensional Data Terminal Options Knob Type Carrier Common Dimensional Data: Length (Knob Type) - 1.69∑ (42.9mm) Plus In-Line Terminal (Screwdriver Slotted) 1.75∑ (44.5mm) NOTE: Plus In-Line Terminal 0.17" 1.58" (4.37mm) (40.03mm) Carrier Options Solder/ ‹Ω¡ §∑ Quick-Connect Maximum Panel Thickness In-Line ⁄Ω¢∑ Quick-Connect Rt. Angle In-Line Rt. Angle ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (“I” Equals Inches) Screwdriver 0.34" (8.7mm) 0.47" 0.33" 0.45" HTB-32I HTB-34I HTB-36I HTB-38I ✓ — HTB-32M HTB-34M HTB-36M HTB-38M — ✓ HTB-52I HTB-54I HTB-56I HTB-58I ✓ — HTB-52M HTB-54M HTB-56M HTB-58M — ✓ HTB-92I HTB-94I HTB-96I HTB-98I ✓ — HTB-92M HTB-94M HTB-96M HTB-98M — ✓ 0.30∑ 7.62mm Low Profile Rear Hex Nut HTB-3 0.41" 1.34" (10.31mm) (34.13mm) Screwdriver (11.5mm) (11.9mm) (8.3mm) 5mm ≈ 20mm (“M” Equals Metric) 0.125∑ 3.18mm High Profile Rear Hex Nut HTB-5 0.17" 1.59" (4.37mm) (40.08mm) 0.125∑ 3.18mm Low-Profile Snap-In HTB-9 Fuseholders and fuse carriers may be ordered separately. Ordering Information FUSE CARRIER ONLY HTB- Packing (Blank) – Std. BK/ – Bulk S Product Symbol Body Configuration and Mounting Finger Grip Holders 2 — Low Profile (Rear Panel Hex-Nut) 4 — High Profile * 6 — (Front Panel Hex-Nut) 8 — Low Profile (Snap-In) Screwdriver Slotted Holders 3 — Low Profile 5 — High Profile 9 — Low Profile (Snap-In) Fuse Carrier I — ⁄Ω¢∑ x 1-1⁄Ω¢∑ M — 5mm x 20mm Rear Terminal Configuration 2 — Solder / ‹Ω¡§∑ Quick-Connect (In-Line) 4 — Solder / ‹Ω¡§∑ Quick-Connect (Right Angle) 6 — ⁄Ω¢∑ Quick-Connect (In-Line) 8 — ⁄Ω¢∑ Quick-Connect (Right Angle) P Splash Proof (Optional on -2, -4, -6, and -8) Packaging (Blank) – Std. BK/ – Bulk Product Symbol FT — Knob Type (For 20, 40, 60, and 80 Series Only) ST — Screwdriver Slotted (For 30, 50, and 90 Series Only) Fuse Carrier I — ⁄Ω¢∑ x 1⁄Ω¢∑ M — 5mm x 20mm *Profile varies with panel thickness. Holder installs thru rear of panel. Data Sheet: 2119 74 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Panel-Mounted for Indicating Type Fuses HLD HJL HK Series Pin Indicating for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses Voltage Rating: 250V, 15A Agency Information: UL Recognized, (File E14853, Guide IZLT2) Lamp Indicating for ⁄Ω¢∑ ≈ 1∑ Fuses Voltage Rating: 250V, 15A No Agency Information Lamp Indicating for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses Voltage Rating: 250V, 15A or 20A Agency Information: UL Recognized, (Guide IZLT2, File E14853) CSA Certified (Class 6225-01, File 47235) 2.81" 2.5" (HLD) (71.4mm) (63.5mm) 1.19" 2.81" (30.2mm) (71.4mm) Flat-Sides 0.69" 1.19" (30.2mm) (17.5mm) 0.81" (20.6mm) Octagonal Sides 2.75" (HLD-HH) (69.9mm) 0.81" (20.6mm) Octagonal Sides Punched Mounting Hole Octagonal Sides Punched Mounting Hole .505" + .005" (16.0mm + .13mm) Punched Mounting Hole .630" + .005" (16.0mm + .13mm) .630" + .005" (16.0mm + .13mm) .473" + .005" .590" + .003" (12.0mm + .13mm) (14.6mm + .08mm) .573" + .003" (14.6mm + .08mm) Electrical Ratings Symbol Electrical Ratings Electrical Ratings Amps Volts Features HLD 15 250 Solder terminals HLD-HH 15 250 ⁄Ω¢ ∑ quick-connect terminals Symbol HJL Amps 15 Use w/GBA, GLD Fuses Lamp Volts 90 to 250 Knob Type Neon Color Type Clear Oct Use w/AGX, MKB Fuses For panels up to ⁄Ω•∑ thick. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Symbol HKL* HKL-X* HKR HKT HKU HKX Amps Lamp Volts Knob Type Color 15 90 to 250 Neon 20 22 to 30 13 to 22 4 to 6 22 to 33 ** ** ** ** Clear Amber Red Amber Type Oct FS Oct Oct Oct FS * UL Recognized and CSA Certified ** Incandescent CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2120 Data Sheet: 2121 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 2105 75 Bussmann® Fuseblocks, Holders and Terminal Blocks In-Line Fuseholders for ⁄Ω¢ ∑ ≈ ‡Ω• ∑ to 1⁄Ω¢ ∑ Fuses HFB HHB HRK Waterproof In-Line Fuseholder for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses Voltage Rating: 32V, 30A Construction: Body - Thermoplastic rubber; Contacts - Copper tin plated Universal In-Line Fuseholder for ⁄Ω¢∑ ≈ ‡Ω•∑, 1∑ and 1⁄Ω¢∑ Fuses Voltage Rating: 32V, 30A Construction: Body - Nylon; Contacts - Copper tin plated Pull Force: 5 lbs. minimum to separate fuseholder housing with fuse installed. UL Flammability Rating: 94 V2 Universal In-Line Fuseholder for ⁄Ω¢∑ ≈ ‡Ω•∑ to 1⁄Ω¢∑ Fuses Voltage Rating: 32V, 15A Catalog Numbers Description Catalog Number Standard Pack (10-in) HFB Bulk Pack (20-in) BK/HFB Replacement Contact Clip BK/1A2294 Electrical Ratings Catalog Symbol HRK Amps 15 Volts 32 Dimensional Data 2.19" Catalog Numbers (55.6mm) Holder (Without Leads) Dimensional Data Fuse Description ⁄Ω¢∑ diameter fuses of different lengths. 0.75" (19.1mm) Description Catalog Number Standard Pack (10-in) HHB Bulk Pack (100-in) BK/HHB 0.69" (17.5mm) 1.56" (39.7mm) Holder With Pre-attached Lead Wires 3" (76.2mm) (#14 Insulated) 0.75" (19.1mm) • Ideal for harsh environments: • –40° to 150° temp. range • Withstands many organic solvents and rigorous shock and vibration. • Accepts #12 to #18 wire leads (not provided). • Simple assembly. • One-piece molded thermo-plastic. • High visibility yellow color for easy identification in dark or hard-toaccess locations. • Important information molded into body. • See Data Sheet for recommended crimp tools. Data Sheet: 2102 76 Wire Color 19∑ Length Yellow BK/HHB-Y419 8∑ Length BK/HHB-Y408 Red BK/HHB-R419 BK/HHB-R408 Black BK/HHB-B419 BK/HHB-B408 • Three springs furnished with fuseholder afford acceptance of ⁄Ω¢∑ fuses of different lengths. • Wire leads are staked and soldered to the contacts of the fuseholder. • Leads are 8∑ (203mm) long. • Wire size - #14. Dimensional Data L 0.53" (13.5mm) Fuse Length Fuseholder Length “L” ‡Ω•∑ (AGW) 2.100 Max. 1∑ (AGX) 2.250 Max. 1⁄Ω¢∑ (AGC, MDL) 2.420 Max. • Accepts #12 to #16 wire leads (not provided with basic fuseholder). • See Data Sheet for recommended crimp tools. Data Sheet: 2103 0.38" (9.5mm) Data Sheet: 2111 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks In-Line Fuseholders HR and HM Series HFA Series HHT Series In-Line Fuseholders for SFE and ⁄Ω¢∑ ≈ Various Length Fuses Voltage Rating: 32V, 20A No agency listings. In-Line Waterproof Fuseholders for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses Construction: Body - Phenolic; Contacts - Copper crimp leads Voltage Rating: 250V, 20A Agency Information: UL Recognized, (Guide IZLT2, File E14853) UL Flammability Rating: 94VO In-Line Fuseholders for 5 x 15mm or 5 x 20mm Fuses Construction: Body - Black Thermoplastic Contacts - Brass Wire - 16 awg, red Electrical Ratings Catalog Symbol Includes Fuse HRJ* SFE-20 HRI SFE-14 HRH SFE-9 HRE SFE-7⁄Ω™ HRG SFE-6 HRF SFE-4 HMJ** Wire 19" of #14 Electrical Ratings Amps 5 10 5 x 15mm 5 x 20mm Volts 32 32 Electrical Ratings Dimensional Data Catalog Symbol Amps Volts Terminals SFE-20 HFA 20 250 Crimp #12 - #16 HMI SFE-14 HFA-HH* 20 250 ⁄Ω¢ ∑ Q.C. HMH SFE-9 HME SFE-7⁄Ω™ HMG SFE-6 HMF SFE-4 *No UL Recognition. 1/4" ± 1/32" 6-3/16" ± 1/4" 8" of #14 6-1/16" ± 1/4" 1.84" (IN ASSEMBLED POSITION) Dimensional Data 2.34" WIRE LENGTH: 13" ± 0.5" (59.5mm) *Also available as in-line fuseholder only with lead wire contacts, HRJ-LES-Fuse. **Also available as in-line fuseholder only with lead wire contacts, HMJ-LES-Fuse. HHJ-A For ⁄Ω¢ 1⁄Ω¢ fuse, no wire or fuse included, accepts #18 - #22 wire. HHJ-B For ⁄Ω¢ 1⁄Ω¢ fuse, no wire or fuse included, accepts #12 - #16 wire. HHI-B For ⁄Ω¢ 1⁄Ω¡§ fuse, no wire or fuse included, accepts #12 - #16 wire. .800" .600" (20.3mm) (15.2mm) 0.42" DIA. 1.84" CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data 2.19" (55.6mm) 0.75" (19.1mm) 0.69" (17.5mm) 1.56" (39.7mm) 0.38" (9.5mm) Data Sheet: 2122 Data Sheet: 2115 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 2138 77 Bussmann® Fuseblocks, Holders and Terminal Blocks Panel-Mounted for ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses HPF HPS Standard Fuseholders with Screw-type Knob for ⁄‹Ω£ ™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses Agency Information: UL Recognized, (Guide IZLT2, File E14853) CSA Certified (Class 6225-01, File 47235) Flammability Rating: UL 94HB • Combination ⁄Ω¢∑ quick-connect/solder terminals. Standard Fuseholders with Bayonet-type Knob for ⁄‹Ω£ ™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses Agency Information: UL Recognized, (Guide IZLT2, File E14853) CSA Certified (Class 6225-01, File 47235) Flammability Rating: UL 94HB • Combination ⁄Ω¢∑ quick-connect/solder terminals. • The -EE, -JJ, -FF and -RR are UL Recognized for applications requiring branch circuit prtection. With Fuse 2.81" Max. E SE F USE FU (71.4mm) 1.00" 1.31" 1.78" HPG and HPD Standard Fuseholders with Bayonet-type Knob for ⁄‹Ω£ ™∑ ≈ 1⁄Ω™∑ Fuses Agency Information: UL Recognized, (Guide IZLT2, File E14853) Flammability Rating: UL 94V0 - Fuseholder body UL 94HB - Knob HPG HPG-EE 2.81" (71.4mm) 0.88" (22.2mm) 1.125" (28.6mm) With Fuse (25.4mm) (33.3mm) (45.2mm) 2.81" FUS (71.4mm) 0.88" (22.2mm) 1.125" (22.2mm) (4.6mm) 2.69" Max. (28.6mm) 1.78" (68.3mm) .250" ± .003" (6.35 ± .08mm) (Typ.2) (45.2mm) Without Fuse .250" ± .003" (6.35 ± .08mm) (Typ.2) 0.180" 0.80" (4.6mm) (20.2mm) 1.125" CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Ratings Fuse Description Electrical Ratings 600 1⁄Ω™∑ (38.1mm) HPF-C 30(4) 600(4) 1⁄Ω™∑ (38.1mm) clear knob. Catalog Symbol 5 600 BBS, ⁄‹Ω£™∑ 1‹Ω•∑ fuses. HPS 15 600 SC 0-15, ⁄‹Ω£™∑ 1fiΩ¡ §∑ fuses. HPS-L Amps Volts Fuse Description 30(3)(4)600 5 600 ⁄‹Ω£™∑ 1⁄Ω™∑ BBS, ⁄‹Ω£™∑ 1‹Ω•∑ fuses. HPF-JJ 20 600 SC 20, ⁄‹Ω£™∑ 1⁄‹Ω£™∑ fuses. HPS-EE 15 600 SC 0-15, ⁄‹Ω£™∑ 1fiΩ¡ §∑ fuses. HPF-FF(2) 30(3) 480 SC 25 & 30, ⁄‹Ω£™∑ 1fiΩ•∑ fuses. HPS-JJ 20 600 SC 20, ⁄‹Ω£™∑ 1⁄‹Ω£™∑ fuses. HPS-F-EE(2) 15 600 HPF-RR 30(3) 600 KTK-R, LP-CC & FNQ-R Class CC fuses. Sleeve on body, leaded for ⁄‹Ω£™∑ 1fiΩ¡ §∑ fuses. HPS-FF(2) 30(3) 480 SC 25 & 30, ⁄‹Ω£™∑ 1fiΩ•∑ fuses. HPF-WT 30(3) 600 Splash-proof knob. HPS-RR(2) 30(3) 600 600 Sleeve on body, leaded for ⁄‹Ω£™∑ 1fiΩ¡ §∑ fuses. KTK-R, LP-CC, FNQ-R Class CC fuses. HPF-F-EE(2) 15 (2)No CSA Certification (3)20A max when used with quick connect terminals. (4)HPF-C ratings for CSA-15A, 250V (1)No UL Recognition (2)No CSA Certification (3)20A max when used with quick connect terminals. (4)HPS rated at 25V for CSA Data Sheet: 2114 Data Sheet: 2113 78 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 30(3) HPF-EE (64.3mm) Without Fuse HPF HPF-L 2.41" (28.6mm) Electrical Ratings Catalog Symbol Amps Volts HPD 0.88" 0.180" DIA. Catalog Symbol Amps Volts HPG 30(3) HPG-EE 15 HPD 30(3) 600 600 600 Fuse Description ⁄‹Ω£™∑ x 1⁄Ω™∑ fuses SC 0-15, ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑ fuses. ⁄‹Ω£™∑ x 1⁄Ω™∑ fuses (3)20A max when used with quick connect terminals. NOTE: • HPG and HPG-EE has combination ⁄Ω¢∑ quickconnect/solder terminals on both side (load) and rear (line) terminals. • HPD has combination ⁄Ω¢∑ quick-connect/solder terminal on side (load) terminal only. Rear (line) terminal is 3/ ∑ shorter than HPG. Rear Terminal solder only. 16 Data Sheet: 2108 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Fuseblocks,Holders Holdersand and Disconnect Terminal Blocks Switches Panel-Mounted for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses HPM HPC-D HPS2 Standard Fuseholder with Screw-type Knob for ⁄‹Ω£ ™∑ ≈ 1⁄Ω™∑ Fuses Agency Information: UL Recognized, (Guide IZLT2, File E14853) CSA Certified (Class 6225-01, File 47235) Flammability Rating: UL 94HB Fuseholder with Screw-type Knob for ⁄‹Ω£ ™∑ ≈ 1⁄Ω™∑ Fuses Agency Information: UL Recognized, (Guide IZLT2, File E14853) • Supplied with O-ring and panel gasket. Flammability Rating: UL 94HB Catalog Symbol: HPS2 Description: Meets requirement of UL 1598 that both poles be removed simultaneously. Fuse Type: 13/32” x 1-1/2” Agency Information: UL 512 recognized, (Guide IZLT2, File E14853) CSA certified: (Class 6225-01, File 47235) Flammability Rating: UL 94V0 Terminals: 1/4” quick connect / solder Electrical Rating: 30A @ 600V (20A max when used with quick-connect terminals.) With Fuse With Fuse 2.73" 2.48" (69.5mm) (63.1mm) 0.94" 0.88" (23.8mm) (22.2mm) 1.775" 1.41" (45.1mm) (30.6mm) 2.594" (65.89mm) 0.180" (4.6mm) Without Fuse 1.120" .250" ± .003" (6.35 ± .08mm) (30.5mm) Electrical Ratings Electrical Ratings Catalog Symbol Amps Volts Description Catalog Symbol Amps Volts ⁄Ω¢∑ quick-connect/solder HPC-D 30(3) 600 Mount in panels up to ⁄ Ω¢∑ thick. HPC-DK(1) 15 600 ⁄ Ω¢∑ quick-connect terminals. HPM 30(3) HPM-D 30(3) 600 600 Splash-resistant knob(4) (3)20A max when used with quick-connect terminals. (4)HPM-D has ⁄Ω¢∑ quick-connect/solder terminal on rear (load) terminal only. The side (line) terminal is ⁄Ω¢∑ quick-connect only. Description (1)No UL Recognition (3)20A max when used with quick-connect terminals. Catalog Symbol HPS2 BK/HPS2 standard 10-in carton bulk 100-in carton Replacement knob - BK/9987SA CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2112 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 2109 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 2140 79 Fuseblocks, Holders and Terminal Blocks Bussmann® Tron® In-Line Fuseholders Single Pole Type SC Fuses HEG Series HEH Series HEC Series HEJ Series In-Line Fuseholders Single-Pole Voltage Rating: 600V, 15A Non-Breakaway Holders In-Line Fuseholders Single-Pole Non-Breakaway Holders Voltage Rating: 600V Current Rating: 20A (CSA - 15A) In-Line Fuseholders Single-Pole Voltage Rating: 480V, 30A Non-Breakaway Holders In-Line Fuseholders Single-Pole Non-Breakaway Holders Voltage Rating: 480V, 60A For SC Fuses 0 to 15A, 480V (or less). Fuse size ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑. For SC-25, & SC-30 Fuses Fuse size ⁄‹Ω£™∑ ≈ 1fiΩ•∑. For SC Fuses; 35A to 60A and Type HVW fuses, ⁄Ω™ to 6A. Fuse size ⁄‹Ω£™∑ ≈ 2⁄Ω¢∑. For Type SC-20 Fuses; 20A, 600V (or less). Also fuse types BBS & KTQ (nominal size ⁄‹Ω£™∑ ≈ 1‹Ω•∑). Data Sheet: 2124 Data Sheet: 2124 Single Pole ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses Data Sheet: 2124 Data Sheet: 2123 Double Pole KTK-R Fuses ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses HEB Series HET Series HEY Series HEX Series In-Line Fuseholders Single-Pole Voltage Rating: 600V, 30A In-Line Fuseholders Single-Pole In-Line Fuseholders Double-Pole Voltage Rating: 600V, 30A In-Line Fuseholders Double-Pole Voltage Rating: 600V, 30A Optional Break-a-way receptacle, polarized, and accepting Class CC branch circuit fuses (Buss type KTK-R, FNQ-R & LP-CC; 600V or less, 200,000A interrupting rating). For any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuse. Typical fuse types: BAF, FNM, FNQ, and KTK (⁄Ω¡º - 30A). Data Sheet: 2126 Data Sheet: 2126 Typical fuse types: BAF, FNM, FNQ, and KTK (⁄Ω¡º - 30A). An HEB - Fuseholder with a permanently installed solid neutral. Easily identified by white plastic coupling nut. Data Sheet: 2127 Data Sheet: 2125 For any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuse. Note: For agency and CE information see the appropriate data sheet. 80 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks For HEB Holders Only Directions:To select complete holder P/N, work from left to right starting with load terminal options and then line terminal options. Then determine breakaway or non-breakaway style. Line Terminal Terminal Type Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Set-Screw Copper Set-Screw Copper Set-Screw Copper Set-Screw Aluminum Set-Screw Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp No. of Terminal Wire Size Wires per Solid Stranded Wire Wire Type Terminal #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #12 to #8 #12 #6, #4 #10 #6, #4 #10 #6, #4 #10 #6, #4 #10 #4 #8 #2 #6 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y #20, #18 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #3 1 Y Y #12 to #2 1 Y Y #8 #6 #6 #4 #3, #4 #2 1 1 1 1 1 1 N Y N Y N Y Y N Y N Y N #1, #2 1 N Y 1/0 1 N Y 1 Y N 1 N Y SolidTerminal #8 to #12 for aluminum connector #10 to #14 (1)UL Recognized, Guide 12LT2, (2)CSA Certified, Class 6225-01, (3)CE File E14853 File 47235 Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Set-Screw Copper set-screw Aluminum Set-Screw Aluminum Set-Screw Aluminum Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Crimp Copper Set-Screw Copper Set-Screw Aluminum Set-Screw Aluminum Set-Screw Aluminum Set-Screw Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Aluminum Crimp Available P/N’s No. of Wire Size Wires per Solid Stranded Wire Terminal Wire #12 to #8 #12 #6 to #4 #10 #4 #8 #2 #6 2/0 #3 1 2 1 2 1 2 1 2 1 2 Y Y Y Y N Y N Y N N Y Y Y Y Y Y Y Y Y Y #12 to #3 1 Y #12 to #3 2 #12 to #2 Non-Breakaway P/N (Boots not included) HEB-AA(1)(2) (3) Breakaway P/N (Boots included) HEB-AW-RLC-A(1)(2) (3) HEB-AB(2) HEB-AW-RLC-B HEB-AC(2) HEB-AW-RLC-C HEB-AD(2) N/A HEB-AE(2) N/A Y HEB-AJ HEB-AW-RLC-J Y Y HEB-AK HEB-AW-RYC 1 Y Y HEB-AL HEB-AW-RLA #12 to #2 2 Y Y HEB-AY HEB-AW-RYA HEB-AR N/A HEB-BA(2) HEB-BW-RLC-A HEB-BB(2) HEB-BW-RLC-B HEB-BC(2) N/A HEB-BD(2) N/A HEB-CC(2) N/A HEB-DD(2) N/A HEB-ZA N/A #1, #2 1 N Y #12 to #8 #12 #6, #4 #10 #4 #8 #2 #6 #4 #8 #2 #6 #12 to #8 #12 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Y Y Y Y N Y N Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y #12 to #3 1 Y Y HEB-JJ HEB-JW-RLC-J #12 to #3 2 Y Y HEB-JK HEB-JW-RYC #12 to #2 1 Y Y HEB-JL N/A #12 to #2 2 Y Y HEB-JY N/A #12 to #2 1 Y Y HEB-LL HEB-LW-RLA #8 #6 #6 #4 #3, #4 #2 1 1 1 1 1 1 N Y N Y N Y Y N Y N Y N HEB-NN N/A HEB-PP(2) N/A HEB-QQ(2) N/A #1, #2 1 N Y HEB-RR(2) N/A 1/0 1 N Y HEB-TT(2) N/A 1 Y N 1 N Y HEB-SS N/A SolidTerminal #8 to #12 for aluminum connector #10 to #14 Contact your local Bussmann representative for other For complete specification data, call Bussmann Information Fax ~ 636.527.1450 81 Bussmann® Fuseblocks, Holders and Terminal Blocks In-Line Fuseholders for Automotive Blade-Type Fuses HHC, HHD, HHF and HHG HHL and HHM HHX In-Line Fuseholders for ATC® Blade-Type Fuses Voltage Rating: 32Vdc Current Rating: See Table. Rated to carry 80% of Fuse Rating continuously. In-Line Fuseholders for MINI-Fuses® Voltage Rating: 32Vdc Current Rating: See Table. Rated to carry 80% of Fuse Rating continuously. In-Line Fuseholders for MAXI-Fuses™ Voltage Rating: 32Vdc Current Rating: See Table. Rated to carry 80% of Fuse Rating continuously. Electrical Ratings Electrical Ratings Electrical Ratings Catalog Symbol Description HHC HHD HHD-C Fuse Size Yellow fuseholder 3-20A Black fuseholder 3-30A Cover only Fits HHD only Black fuseholder 3-20A with cover Black fuseholder 3-30A with cover HHF HHG Electrical Connection Catalog Symbol #16 black leadwire #12 yellow leadwire Clear polycarbonate HHL HHL-B HHM #12 yellow leadwire HHM-B Description Fuse Size BK/HHC-R Yellow fuseholder 3-20A BK/HHF-B Black fuseholder 3-20A with cover Black fuseholder w/cover 2-20A Black fuseholder – body only 2-20A Black fuseholder w/cover 2-30A Black fuseholder – body only 2-30A #16 yellow leadwire Bulk Products (Bulk Quantity - 1000 Pieces) Catalog Symbol Description Fuse Size Electrical Connection #16 red leadwire #16 black leadwire A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. 0.78" 0.364" HHM-C Electrical Connection Catalog Symbol #16 black leadwire, 4” length stripped to ⁄Ω¢” #16 black leadwire, 4” length stripped to ⁄Ω¢” #12 red leadwire, 4” length stripped to ⁄Ω¢” #12 red leadwire, 4” length stripped to ⁄Ω¢” HHX Black cover only HHX-B HHX-C Description Fuse Size Black fuseholder w/cover 20-60A Black fuseholder – body only 20-60A Electrical Connection #6 red leadwire, 5” with blunt ends #6 red leadwire, 5” with blunt ends Black cover only A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. Bulk Products (Bulk Quantity - 1000 Pieces) Catalog Symbol BK/HHL-R Description Black fuseholder – body only Fuse Size Electrical Connection 2-20A #16 red leadwire, 4” length stripped to ⁄Ω¢” A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. 0.91" 0.5" 0.38" 0.30" 0.25" 4.0" + 0.25" Data Sheet: 2107 82 1.125" 4.0" + 0.25" Data Sheet: 2128 Data Sheet: 2129 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks For ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fuses 4405 4406 Series 8000 Bolt-in and Snap-in Mounting for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses Construction: Blocks are molded flame retarded thermoplastic. Clips are spring-bronze. Voltage Rating: 300V Agency Information: UL Recognized ; File E14853A, Guide IZLT2 CSA Certified Class 6225-01, File 47235 Anti-Rotation Pin: Single pole blocks may be ordered without the antirotational pin simply by adding an “X” to the number of poles (Example: BK/S-8000-1X). Carton Quantity: 10; shelf package: 100. Bulk Carton: Single-pole and 2-pole fuse blocks–1,000; Multiple-pole fuse blocks–3-8 pole: 200; 9-12 pole: 50. When ordering bulk quantities, prefix “BK/” to catalog number: (Example: BK/S-8001-1-SNP). ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Single Pole (6.4mm ≈ 31.8mm) Bakelite base; spring-bronze, bright tin-lead plate clips; 30A, 250V; base width ⁄Ω™∑ (12.7mm). No. 4405—0° Solder Terminals. Integral terminal and clip. 2.31" (58.7mm) 0.27" 0.69" (17.5mm) (6.7mm) 1.63" (41.3mm) Bolt-in Mounting Series Terminal Angle Basic Cat. No. Amperes Poles (Suffix) 8000 Solder 0° 40° S-8001S-8002- UL 25A CSA 21A 8100 ‹Ω¡§∑ Quick Connect 0° 40° S-8101S-8102- UL 20A CSA 13A 8200 ⁄Ω¢∑ Quick Connect 0° 40° Side S-8201S-8202S-8203- UL 20A CSA 16A 8300 Screw — S-8301- UL 30A CSA 25A Series Terminal Angle Cat. No. Amperes Poles (Suffix) 8000 Solder 0° 40° S-8001-1-SNP S-8002-1-SNP UL 25A CSA 21A Available 8100 ‹Ω¡§∑ Quick Connect 0° 40° UL 20A CSA 13A 8200 ⁄Ω¢∑ Quick Connect 0° Side S-8101-1-SNP S-8102-1-SNP S-8201-1-SNP S-8203-1-SNP 1.63" (41.3mm) 0.69" 1 - 12 Snap-in Mounting Catalog Code BK/ S-8 0 00 UL 20A CSA 16A No. 4406—Side Solder Terminal No. 4574—Spare Fuseblock (17.5mm) No. 2499—Side Quick-Connect Terminals. ⁄Ω¢∑ (6.4mm); 15A, 250V. UL Recognized, Guide IZLT2, File E14853. only in 1.63" 0.75" (41.3mm) (19.1mm) 0.27" 0.72" (6.7mm) (18.3mm) single pole 0.5" (12.7mm) Note—Mounting screw hole diameter is 0.147∑ (3.7mm). Counterbore diameter, 0.636∑ (8.0mm). Max. Mounting Screw No. 6. -00 Prefix for Bulk Packing Series 8000 Product Line Type Terminal “0”-Solder “1”-‹Ω¡§∑ Quick Connect “2” - ⁄Ω¢∑ Quick Connect “3” - Screw Terminal Angle “01” - straight (0°,) “02”- 40° “03” - side* Number of Poles (1-12) 0.27" (6.7mm) 2499 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. *Available only in single pole 4574 Data Sheet: 2101 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 83 Bussmann® Fuseblocks, Holders and Terminal Blocks For ⁄Ω¢ ∑ ≈ 1∑ Fuses Series 3828 4520 and 4393 Solder Terminals Fuseblock for ⁄Ω¢∑ ≈ 1∑ Fuses (6.4mm ≈ 25.4mm) Single Pole Fuseblock for ⁄Ω¢∑ ≈ 1∑ Fuses Bakelite base; Width ⁄Ω™∑ (12.7mm). Spring-bronze, bright tin-lead plated clips. Rated 30A, 250V. No. 4520—Solder terminals; straight; integral clip and terminal. 1.88" (47.6mm) 0.63" 1.94" (15.9mm) (49.2mm) .188" .598" (4.8mm) 0.19" 1.38" (4.8mm) (34.9mm) (15.2mm) 1.38" (34.9mm) Catalog And Dimensional Data Catalog Number No. of Poles *Base Length No. 4393—Spare fuseblock. inches mm 12.7 Note—Mounting screw hole diameter is 0.147∑ (3.7mm), counterbore 0.636∑ (8.0mm) diameter. Max. Mounting Screw No. 6. 3828-1 1 ⁄Ω™ 3828-2 2 1⁄ Ω• 28.6 3828-3 3 1‹Ω¢ 44.5 1.38" 3828-4 4 2‹Ω• 60.3 (34.9mm) 3828-5 5 3 76.2 3828-6 6 3fiΩ• 92.1 3828-7 7 4⁄Ω¢ 108.0 3828-8 8 4‡Ω• 123.8 3828-10 10 6⁄Ω• 155.6 3828-12 12 7‹Ω• 187.3 .598" (15.2mm) .188" (4.8mm) *Small phenolic base, base width 1‹Ω •∑ (34.9mm) Note—Mounting screw hole diameter is 0.147∑ (3.7mm) Max. Mounting Screw No. 6. 84 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Printed Circuit Board for 5mm Diameter Fuses HTC-15M, HTC-140M .217" 1.047" PCB Fuseblock and Snap-On Cover Voltage Rating: 250V, 6.3A, 1.6W HTC-15M (Fuseholder), HTC-140M (Natural Cover), HTC-150M* (Transparent Cover) (26.6mm) .345" .531" (9.0mm) (13.5mm) HTC-140M Cover .571" (14.5mm) (5.5mm) Mounting Holes .890" .866" (22.60mm) (22.0mm) _ .002" Dia. (Typ.) .059" + .177" 217" + .05mm) (1.50 _ (4.5mm) *Available in bulk only. Use this format: BK/HTC-150M PC Board Mount Fuseclip Construction: Tin plated bronze Tape and Fan Fold packed Ammo Pack (AP/HTC-200M) 1000 pieces per box .319" .50" (8.1mm) (12.7mm) BUSS .177" (4.5mm) BUSS HTC-200M BUSS Data Sheet: 2110 .157" (3.99mm) .929" (23.6mm) .61" (15.5mm) .031" (.79mm) .012" .217" (.3mm) (5.5mm) .50" .50" HTC-210M Data Sheet: 2110 (12.7mm) (12.7mm) 4.32mm PC Board Mounted Fuseclip with End Stops 2.54mm 8.73mm 6.26mm 2.29mm 2.54mm 1.46mm 2.54mm 3.91mm 6.22mm 2.85mm Data Sheet: 2110 1A3399 Series .062" .115" Fuseclips with End Stops and Straight Leads Catalog Number Clip Material* Finish 1A3399-01 Beryllium Copper* Silver 1A3399-04 Beryllium Copper* Bright Tin 1A3399-10 Spring Bronze Bright Tin .254" .225" .125" (1.6mm) (2.9mm) (5.7mm) (3.2mm) .030" (1.6mm) .237" (6.5mm) (6.0mm) .060" .125" (1.5mm) (3.2mm) .188" (4.8mm) Data Sheet: 2131 *Beryllium copper recommended for currents higher than 15 amps (⁄Ω¢∑ clips). ( 1A5018 Series ) .180" .440" Fuseclips with End Stops and Straight Leads (4.57mm) (11.2mm) High Profile Catalog Number Clip Material* Finish 1A5018-7 Spring Bronze Silver 1A5018-10 Spring Bronze Bright Tin .047" (1.2mm) .140" .180" (3.7mm) (4.6mm) .230" (5.84mm) Data Sheet: 2131 *Beryllium copper recommended for currents higher than 15 amps (⁄Ω¢∑ clips). 1A5601 Series .246" .344" + .015" (6.3mm) (8.73mm + 0.38mm) Fuseclips (0-7A) .250" (6.35mm) .344" + .015" (8.73mm + 0.38mm) Catalog Number Clip Material Finish 1A5601 Cartridge Brass Bright Tin .141" + .015" (3.58mm + 0.38mm) .060" .266" (1.5mm) (6.75mm) .022" + .002" .032" + .002" (0.56mm + 0.05mm) (.81mm + .05mm) Data Sheet: 2131 .219" 1A5602 Series (5.57mm) Fuseclips (0-7A) .500" .250" (12.70mm) Catalog Number Clip Material Finish 1A5602 Cartridge Brass Bright Tin (6.35mm) .140" (3.56mm) .093" (2.36mm) .047" .216" (5.48mm) LEGS TO FIT IN .052" (1.3mm) DIA. HOLES ON CENTER (1.19mm) Data Sheet: 2131 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 85 Bussmann® Fuseblocks, Holders and Terminal Blocks Printed Circuit Board for ⁄Ω¢ ∑ Diameter Fuses 1A3398 Series Fuseclips without End Stops and Straight Leads Catalog Number Clip Material Finish 1A3398-07 Cartridge Brass Bright Tin 1A3398-08 Spring Bronze Bright Tin .102" Dia. .280" (2.6mm) (7.1mm) .255" (6.5mm) .245" .155" (6.2mm) (3.94mm) .410" (10.4mm) .060" (1.5mm) .320" .140" .102" Dia. .280" (2.6mm) (7.1mm) .280" (3.6mm) (7.1mm) (8.13mm) 1A1907 Series Fuseclips with End Stops and Straight Leads Catalog Number 1A1907-02 1A1907-03 1A1907-05 1A1907-06 1A1907-08 1A1907-09 Clip Material* Cartridge Brass Beryllium Copper* Beryllium Copper* Cartridge Brass Spring Bronze Spring Bronze Finish None/Bright Dipped Bright Tin Silver Bright Tin None/Bright Dipped Bright Tin Data Sheet: 2131 .102 Dia. .280 (2.6mm) (7.1mm) .255" (6.5mm) .245" .155" (6.2mm) (3.94mm) .410" (10.4mm) .060" (1.5mm) .320" .140" .102" Dia. .280" (2.6mm) (7.1mm) .280" (3.6mm) (7.1mm) (8.13mm) Data Sheet: 2131 *Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips). .245" 1A4533 Series Fuseclips without End Stops and Angled Out Leads 1A4533-01 Beryllium Copper* Bright Tin 1A4533-06 Cartridge Brass Bright Tin (6.5mm) 1A4533-07 Spring Bronze Bright Tin .060" Finish *Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips). .255" .150" (3.81mm) (1.5mm) .320" .280" (8.13mm) (7.11mm) .228" (5.79mm) .323" Data Sheet: 2131 (8.20mm) .245" 1A4534 Series .155" (6.2mm) Fuseclips with End Stops and Angled Out Leads (3.94mm) .102" (2.6mm) .410" Catalog Number Clip Material* 1A4534-01 Beryllium Copper* Bright Tin 1A4534-06 Cartridge Brass Bright Tin 1A4534-07 Spring Bronze Bright Tin (10.4mm) Finish *Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips). .255" (6.5mm) .060" .150" (3.81mm) (1.5mm) 1A1120 Series .320" .280" (8.13mm) (7.11mm) .228" (5.79mm) .323" Data Sheet: 2131 (8.20mm) .265" Finish None/Bright Dipped Silver Bright Tin Bright Tin None/Bright Dipped Bright Tin .132" (6.7mm) Fuseclips without End Stops and Angled In Leads (3.4mm) .410" (10.4mm) .187" (4.8mm) .255" (6.5mm) .080" (3.9mm) (2.03mm) (7.4mm) .360" (9.14mm) Data Sheet: 2131 1A1119 Series .285" Clip Material* Finish 1A1119-04 Beryllium Copper* Bright Tin 1A1119-05 Beryllium Copper* Silver 1A1119-10 Cartridge Brass Bright Tin 1A1119-13 Spring Bronze Bright Tin *Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips). .132" (7.24mm) Fuseclips with End Stops and Angled In Leads Catalog Number .312" (7.9mm) .290" .155" *Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips). 86 .102" (2.6mm) .410" Clip Material* Clip Material* Cartridge Brass Beryllium Copper* Beryllium Copper* Cartridge Brass Spring Bronze Spring Bronze (3.94mm) (10.4mm) Catalog Number Catalog Number 1A1120-02 1A1120-05 1A1120-06 1A1120-09 1A1120-11 1A1120-12 .155" (6.2mm) (3.4mm) .420" (10.67mm) .187" (4.8mm) .250" (6.5mm) .080" (2.03mm) .290" .155" (3.9mm) .312" (7.9mm) (7.4mm) .360" (9.14mm) Data Sheet: 2131 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Printed Circuit Board Fuseclips ( 1A3400 Series ) .470" Fuseclips for ⁄‹Ω£™∑ diameter fuses with End Stops and Straight Leads Catalog Number Clip Material Finish 1A3400-09 Spring Bronze Bright Tin 20A Maximum .050" .710" (18.0mm) .080" (2.0mm) .470" .437" (1.27mm) (11.1mm) (11.9mm) .218" (5.5mm) .142" Dia. (3.6mm) .380" (9.7mm) (11.9mm) Data Sheet: 2131 1A5600 Series .295" Fuseclips for ATC® Fuses (0-20A) Catalog Number Clip Material Finish 1A5600 Brass Satin Finish Tin (7.49mm) .330" (8.38mm) .180" (4.57mm) .053" (1.35mm) .150" (3.81mm) .200" (5.08mm) .090" (2.29mm) .090" (2.29mm) Data Sheet: 2131 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 87 Bussmann® Fuseblocks, Holders and Terminal Blocks Printed Circuit Board Fuseclips 5681 & 5682 Series Fuseclips with Mounting Holes For ⁄Ω¢∑ Diameter Fuses Dimensions (Inches) Catalog Number End Clip Stop Mat.** 5681-08 5681-15 5682-01 5682-02 5682-41 5682-44 No Yes Spg. Br. Spg. Br. BeCU BeCU Spg. Br. Spg. Br. Finish Nickel Bright Tin Silver Silver Bright Tin Bright Tin B (To C End Stop) (Contact) † .106 .132 .106 .132 D (Height) E Hole (Width) Dia. Fig. Ref. .265 .410 .320 .132 2 .260 .410 .320 .132 1 Data Sheet: 2132 B C 5672 & 5674 Series Fuseclips with Mounting Holes For ·Ω£™∑ Diameter Fuses Dimensions (Inches) Catalog Number End Clip Stop Mat.** 5672-11 No 5674-01 5674-10 Yes 5674-41 Finish Spg. Br. Bright Tin BeCU Silver BeCU Albaloy Spg. Br. Bright Tin B (To C End Stop) (Contact) D (Height) E Hole (Width) Dia. Fig. Ref. † .362 .520 .380 .172 2 .168 .356 .520 .380 .172 1 D E FIGURE 1 Data Sheet: 2132 5956 & 5960 Series Fuseclips with Mounting Holes For ⁄‹Ω£™∑ Diameter Fuses Dimensions (Inches) Catalog Number End Clip Stop Mat.** 5956-16 No Finish B (To C End Stop) (Contact) Spg. Br. Bright Tin BeCU Silver 5960-09 BeCU Silver .200 .172 5960-23 BeCU Albaloy .168 .196 Yes .312 .710 E Hole (Width) Dia. 5960-07 5960-51 † D (Height) .470 .168 .172 Fig. Ref. 2 .196 Spg. Br. Bright Dip* .168 5960-53 Spg. Br. Bright Dip* .200 .389 .710 .470 .172 .196 5960-61 Spg. Br. Bright Tin .168 .196 5960-62 Spg. Br. Bright Tin .168 .132 5960-63 Spg. Br. Bright Tin .200 .172 5960-64 Spg. Br. Bright Tin .200 .128 1 C Data Sheet: 2132 5591 & 5592 Series Fuseclips with Mounting Holes For ·Ω¡§∑ Diameter Fuses D Dimensions (Inches) Catalog Number End Clip Stop Mat.** 5591-42 5592-01 5592-11 5592-33 Yes No Spg. Br. BeCU Spg. Br. Spg. Br. Finish Bright Dip* Silver Silver Bright Dip* B (To C End Stop) (Contact) D (Height) E Hole (Width) Dia. .260 .510 .890 .600 † .505 .890 .600 .172 .200 .200 .172 Fig. Ref. 1 2 E FIGURE 2 * Bright Dip is actually treated bare metal with no plating. ** Spg. Br. — Spring Bronze; BeCU — Beryllium Copper. † Hole in center of both clip and contact area. 1A1837 For ⁄‹Ω¡§∑ Diameter Fuses Data Sheet: 2132 88 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Rail Mount Terminal Blocks Series NDN 35mm DIN Rail Compatible High Density Design: Up to 48 circuits per foot Clamping Collar: Secures wires Large, Captive, Wire-ready Screws: Speeds assembly Snap-on Installation to DIN Rail: Fast, easy assembly Fully Shielded Construction: 600V spacings Unique One-piece Construction: Increases reliability Thermoplastic Moldings: Strong and impact resistant Material: UL Recognized 94V-2 thermoplastic Collars: Heat treated stainless steel Terminals: Tin plated copper alloy Screws: Zinc plated steel Agency Information: UL E62622; CSA LR15364 NDNV4-__ __(color) NDN3-__ __(color) NDN63-__ __(color) Ratings: NDNV4 30A, 600V; UL/CSA Center Spacing: .250∑ (6.35) Number of Poles: 4 Circuits per Foot: 48 Circuit Jumper: JN4, 4 circuits Wire Size: AWG #10-22 CU Screw Size: #6-32 Mounting Options: 35mm DIN rail, C-rail Marking Tape: MTC6 Torque Rating: 18 in/lb max. NDNV4 Colors: YE - Yellow WH - White Ratings: 30A - field wiring; 40A - factory wiring 600V; UL/CSA Center Spacing: .300∑ (7.62) Number of Poles: 3 Circuits per Foot: 38 Circuit Jumper: JNDN3, 2 circuits Wire Size: AWG #10-22 CU Screw Size: #6-32 Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. NDN3 Colors: YE - Yellow WH - White Ratings: 65A, 600V; UL/CSA Center Spacing: .375∑ (9.52) Number of Poles: 3 Circuits per Foot: 30 Circuit Jumper: JN3, 2 circuits Wire Size: AWG #6-18 CU Screw Size: #10-32 Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-⁄Ω™ Torque Rating: 35 in/lb max. NDN63 Colors: YE - Yellow WH - White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 89 Bussmann® Fuseblocks, Holders and Terminal Blocks Rail Mount Terminal Blocks NDN1-WH Ratings: 90A, 600V Center Spacing: .635∑ (16.13) Number of Poles: 1 Circuits per Foot: 18 Circuit Jumper: JN1, 2 circuits Wire Size: AWG #2-18 CU Screw Size: ⁄Ω¢-28 Mounting Options: 35mm DIN rail, C-rail (Dove-tail option is available for mounting side-by-side. Order part no. NDN1A-WH.) Marking Tape: MT12-⁄Ω™ Torque Rating: 32 in/lb max. NDN1Colors: WH -White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. NDN111-__ __(color) Ratings: 90A, 600V; UL/CSA Center Spacing: .635∑ (16.13) Number of Poles: 3 Circuits per Foot: 18 Circuit Jumper: JN1, 2 circuits Wire Size: AWG #2-18 CU Screw Size: ⁄Ω¢-28 Mounting Options: 35mm DIN rail, C-rail, Base Mount. (Dove tail option is available for mounting side-by-side. Order part no. NDN111A-WH.) Marking Tape: MT12-⁄Ω™ Torque Rating: 32 in/lb max. NDN111 NDN111A Colors: Colors: YE - Yellow YE - Yellow WH - White WH- White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Series NDN Terminal Block Accessories NDNA NDNAS 35mm DIN rail 35mm DIN rail Aluminum End Stop NDNA 100 1 meter NDNA 200 2 meters 90 NFTA NRA37-1/2 SOA72 C-rail Aluminum NFTA36 36” long NFTA72 72” long C-rail Low profile No flange Aluminum 37⁄Ω™∑ length 72” long Stand-Off Channel for C-rail MARKING JUMPERS TAPE See series See series specifications specifications For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Rail Mount Terminal Blocks N512-BK NFT2-__ __(color) NFT3-__ __(color) Ratings: 5A, 600V; UL/CSA 20A, 300V; UL/CSA Center Spacing: .197∑ (5.00) Number of Poles: 12 Circuits per Foot: 60 Circuit Jumper: JN512, 12 circuits Wire Size: AWG #12-22 CU Screw Size: #4-48 Mounting Options: C-rail, 15mm DIN rail Marking Tape: AT512 Torque Rating: 12 in/lb max. Color: Black-BK Ratings: 40A, 600V; UL/CSA; 55A factory wired. Center Spacing: .281∑ (7.13) Number of Poles: 2 Circuits per Foot: 38 Circuit Jumper: JN2, 2 circuits Wire Size: AWG #8-22 CU Screw Size: #8-32 Mounting Options: C-rail Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. NFT2 Colors: WH - White Ratings: 40A, 600V; UL/CSA; 55A factory wired. Center Spacing: .390∑ (9.91) Number of Poles: 3 Circuits per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Size: AWG #8-22 CU Screw Size: #8-32 Mounting Options: C-rail Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. NFT3 Colors: YE - Yellow WH - White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. NC3-WH NSE3-WH NSS3-WH Ratings: 175A, 600V; UL/CSA Center Spacing: 1.06∑ (26.92) Number of Poles: 3 Circuits per Foot: 11 Wire Size: 2/0-#14 CU/AL Screw Size: fiΩ¡§-24 Mounting Options: C-rail, Base Mount Marking Tape: MT12-⁄Ω™ Torque Rating: 45 in/lb max. NC3 Colors: WH - White Ratings: 115A, 600V; UL/CSA Center Spacing: 1.06∑ (26.92) Number of Poles: 3 Circuits per Foot: 11 Wire Size: For use with wire crimped to ring terminal. Screw Size: ⁄Ω¢-28 Mounting Options: C-rail, Base Mount Marking Tape: MT12-⁄Ω™ Ratings: 30A, 600V; UL/CSA Center Spacing: .385∑ (9.77) Number of Poles: 3 Circuits per Foot: 28 Circuit Jumper: JNSS3, 2 circuits Wire Size: For use with wire crimped to ring terminal. Screw Size: #6-32 Mounting Options: C-rail Marking Tape: MT12-⁄Ω™ NSS3 Colors: WH - White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 91 Bussmann® Fuseblocks, Holders and Terminal Blocks Sectional Terminal Blocks PSU1-WH PLU3-_ _(color) PLU1-WH Depluggable Rail Mount Ratings: 40A, 600V; UL/CSA Center Spacing: .390∑ (9.91) Number of Poles: 3 Circuits per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Size: AWG #8-22 CU Screw Size: #8-32 Mounting Options: C-rail, Stackable Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. PLU3 Colors: YE - Yellow WH - White Depluggable Rail Mount Ratings: 70A, 600V; UL/CSA Center Spacing: .625∑ (15.88) Number of Poles: PLU1-WH (1 pole); PLU11-WH (2 poles); PLU111-WH (3 poles) Circuits per Foot: 19 Circuit Jumper: JN1, 2 circuits Wire Size: AWG #4-18 CU Screw Size: ⁄Ω¢-28 Mounting Options: C-rail, Stackable Marking Tape: MT12-⁄Ω™ Torque Rating: 32 in/lb max. PLU1 PLU11 PLU111 Colors: Colors: Colors: WH- White WH -White WH- White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Depluggable Rail Mount Ratings: 45A*, 600V; UL/CSA (*45A rating achieved with ring terminal crimped to wire) Center Spacing: .625∑ (15.88) Number of Poles: PSU1-WH (1 pole); PSU11-WH (2 poles); PSU111-WH (3 poles) Circuits per Foot: 19 Wire Size: For use with crimp on connectors only. Screw Size: #10-32 Mounting Options: C-rail, Stackable Marking Tape: MT12-⁄Ω™ Torque Rating: 32 in/lb max. PSU1 PSU11 PSU111 Colors: Colors: Colors: WH- White WH -White WH- White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. PLK3-_ _(color) KT3-WH KT4-WH Base Mount Ratings: 40A, 600V; UL/CSA Center Spacing: .390∑ (9.91) Number of Poles: 3 Circuits per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Size: #8-22 CU Screw Size: #8-32 Mounting Options: Base Mount, Stackable. KAD end mount adapter optional. Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. KT3 Colors: WH - White Base Mount Ratings: 30A, 600V; UL/CSA Center Spacing: .250∑ (6.35) Number of Poles: 4 Circuits per Foot: 48 Circuit Jumper: JN4, 4 circuits Wire Size: AWG #10-22 CU Screw Size: #6-32 Mounting Options: Base Mount. Mounting screws recommended every 12 circuits. Marking Tape: MTC6 Torque Rating: 18 in/lb max. KT4 Colors: WH - White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 92 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Base Mount Ratings: 40A, 600V; UL Center Spacing: .390∑ (9.91) Number of Poles: 3 Circuits per Foot: 28 Circuit Jumper: JN3, 2 circuits Wire Size: AWG #8-22 CU Screw Size: #8-32 Mounting Options: Base Mount, Stackable. End Piece (Part No. KAD) is required for mounting. Mounting screws recommended every 15 circuits. Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. PLK3 Colors: YE - Yellow WH - White CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Quick Connect Terminal Blocks NTQ23-WH BNQ21-WH BQQ41-WH Ratings: 40A, 600V Center Spacing: .390∑ (9.91) Number of Poles: 3 Circuits per Foot: 28 Wire Size: AWG #8-22 CU Screw Size: #8-32 Mounting Options: C-rail Marking Tape: MT12-⁄Ω™ Color: White-WH Torque Rating: 18 in/lb max. Ratings: 40A, 600V; UL/CSA Center Spacing: .437∑ (11.10) Number of Poles: 1 Circuits per Foot: 24 Wire Size: AWG #8-22 CU Screw Size: #8-32 Quick Connects: .250∑ ≈ .031∑ Mounting Options: Base Mount, Stackable. End Piece (Part No. BQE) is required for mounting. Mounting screws recommended every 8 circuits. Torque Rating: 18 in/lb max. Ratings: 30A, 600V; UL/CSA Center Spacing: .437∑ (11.10) Number of Poles: 1 Circuits per Foot: 24 Wire Size: For use with quick connect terminals only. Quick Connects: .250∑ ≈ .031∑ Mounting Options: Base Mount, Stackable. End Piece (Part No. BQE) is required for mounting. Mounting screws recommended every 8 circuits. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 93 Fuseblocks, Holders and Terminal Blocks Bussmann® Rail Mount Fuseholders and Circuit Breakers NDNF1-WH NDNLFD1 Ratings: 30A, 600V; UL/CSA Number of Poles: 1 Fuse Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (KTK, FNQ). Circuit Jumper: JF1, 2 circuits Wire Size: AWG #8-22 CU Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. NDNF1 Colors: WH - White Fuse Pullers (Optional): PF1 Lighted neon or incandescent – LPF-(Voltage rating) LPF1-24 LPF1-120 LPF1-120-C LPF1-220 LPF1-440 Ratings: NDND1: 30A, 600V; UL/CSA (non-fused) NDNFD1: 15A, 600V/CSA (fused) NDNLFD1*: 15A, 600V (fused) Number of Poles: 1 Fuse Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑ (Buss® AGC, MDL or equivalent.) Circuit Jumper: JF1, 2 circuits Wire Size: AWG #8-22 CU Mounting Options: 35mm DIN rail, C-rail Marking Tape: MT12-⁄Ω™ Torque Rating: 18 in/lb max. Extension: WH - White *WH24 - 24V White (Only available with NDNLFD1) 94 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Fuseblocks, Holders and Terminal Blocks Bussmann® Power Distribution Blocks Series 11675 Series 11725 Quick-Connect Power Distribution Block Quick-Connect Power Distribution Block Ratings: 40A, 250V; UL/CSA Poles: 2 to 6 poles with (3) .250∑ quick-connect terminals per pole. Input Wire Sizes: #8 – #14 CU Torque Rating: 9 in/lb max. Design: For equipment that requires screw connections in the field. Reduces assembly costs of internal wiring. Agency Information: UL E62622; CSA LR15364 Ratings: 70A, 600V; UL/CSA Poles: 2, 3 or 4 poles with (4) .250∑ quick-connect terminals per pole. Input Wire Sizes: #2 – #14 CU/#8 AL Torque Rating: 45 in/lb max. Design: For equipment that requires screw connections in the field. Reduces assembly costs of internal wiring. Agency Information: UL E62622; CSA LR15364 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Series 14002 Barrier Terminal Block Ratings: 115A, 600V; UL/CSA Poles: 2 to 6 poles Wire Sizes: #2 – #14 CU/#8 AL Marking: Marking strip optional, consult factory. Options For Load Side Connector: CP: Sems pressure plate, rated 60A, 600V Q: Quick-Connect, rated 50A, 600V To order options, enter letter code in front of Part No.: ie; CP14002-2. Agency Information: UL E62622; CSA LR15364 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Series 14004 Dead Front Terminal Block Ratings: 90A, 600V; UL/CSA Poles: 2 to 12 poles Wire Sizes: #4 – #14 CU/#8 AL Marking: Marking strip optional, consult factory. Agency Information: UL E62622; CSA LR15364 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 95 Bussmann® Fuseblocks, Holders and Terminal Blocks Power Distribution & Terminal Blocks Series 162, 163, 165 Series 160, 162, 163 & 165 Ratings: To 840A, 600V; UL Recognized/CSA. See Table. Materials: Molded material: Black, UL rated 94V-0 thermoplastic. Agency Information: UL E62622 General Industrial Class per UL 1059; CSA LR15364. Power Distribution Blocks (600V) Catalog Data Part Number *16021 *16023 16220 16321 16323 16325 16330 Line Connection 2/0-#14CU, 2/0-#8AL 350kcmil-#6CU-AL 2/0-#14CU, 2/0-#8AL 2/0-#14CU, 2/0-#8AL 350kcmil-#6CU-AL (2)2/0-#14CU, 2/0-#8AL 500kcmil-#6CU-AL 16332 350kcmil-#6CU-AL 16335 500kcmil-#6CU-AL 16370 350kcmil-#6CU-AL 16371 350kcmil-#6CU-AL 16372 350kcmil-#6CU-AL 16373 350kcmil-#6CU-AL 16375 600kcmil-#2CU-AL 16376 600kcmil-#2CU-AL 16377 (2)300kcmil-#4CU-AL 16528 (2) 16530 16541 (2)500kcmil-#6CU-AL 600kcmil-#2CU-AL 500kcmil-#6CU-AL Connector Load Material & Connection Ampacity (6)#4-#14CU, #4-#8AL AL-175A 6)#4-#14CU, #4-#12AL AL-310A (4)#4-#14CU, #4-#8AL AL-175A (6)#4-#14CU, #4-#8AL AL-175A (6)#4-#14CU, #4-#12AL AL-310A (6)#4-#14CU, #4-#8AL AL-350A (6)#2-#14CU, #2-#12AL AL-380A (3)#2-#14CU, #2-#8AL AL-310A (2)1/0-#14CU, 1/0-#8AL (3)#2-#14CU, #2-#8AL AL-380A (2)1/0-#14CU, 1/0-#8AL (12)#4-#14CU, #4-#12AL AL-310A (6)#2-#14CU, #2-#8AL AL-310A (3)1/0-#14CU, 1/0-#8AL (21)#10-#14CU, #10AL AL-310A (3)1/0-#14CU-AL AL-310A (14)#10-#14CU, #10AL (12)#4-#14CU, #4-#12AL AL-420A (6)#2-#14CU, #2-#8AL AL-420A (3)1/0-#14CU, 1/0-#8AL (12)#4-#14CU, #4-#12AL AL-570A (4)3/0-#6CU-AL AL-840A (4)#4-#14CU-AL (12)#4-#14CU-AL AL-760A (21)#6-#14CU-AL AL-380A Agency Information UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL UL CSA — CSA UL CSA UL CSA UL CSA UL CSA UL CSA UL — UL CSA UL UL CSA — *160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165) have mounting holes within barriers. See Data Sheet for dimensional drawings. How To Order: Catalog Number + # of Poles Example: 16020 – 3 (complete part number) Optional covers: 160 Series: CPB160 - (pole) 162 Series: CPB162 - (pole) 163 Series: CPDB- (pole) 165 Series: CPDB165 (1 for each pole) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1117 (Series 160, 162, 165); 1148 (Series 163) 96 Ratings: To 760A, 600V; UL Recognized/CSA. See Table. Materials: Molded material: Black, UL rated 94V-0 thermoplastic. Agency Information: UL E62622 General Industrial Class per UL 1059; CSA LR15364. Connector–Stud Blocks (600V) Catalog Data Part Line Number Connection Connector to Stud 16280 2/0-#14CU-AL 16281 2/0-#14CU-AL 16378 500kcmil-#6CU-AL 16383 500kcmil-#6CU-AL (2)500kcmil-#6CU-AL 16582 Stud to Stud 16290 ⁄Ω¢-20 ≈ ‹Ω¢ Stud 16390 ‹Ω•-16 ≈ 1⁄Ω• Stud 16394 ⁄Ω™-13 ≈ 1⁄Ω¡§ Stud 16395 ‹Ω•-16 ≈ 1‡Ω¡§ Stud 16591 ‹Ω•-16 ≈ 1‡Ω¡§ Stud 16593 ⁄Ω™-13 ≈ 1 Stud Load Connection Connector Material & Ampacity ⁄Ω¢-20 ≈ ‹Ω¢ Stud ⁄Ω¢-20 Tapped hole (2)⁄Ω¢-20 ≈ 1 Stud (1)‹Ω•-16 ≈ 1 Stud (2)‹Ω•-16 ≈ 1fiΩ• Stud AL-175A AL-175A AL-380A AL-380A AL-760A UL UL UL UL UL CSA CSA CSA CSA CSA ⁄Ω¢-20 ≈ ‹Ω¢ Stud ‹Ω•-16 ≈ 1⁄Ω• Stud ⁄Ω™-13 ≈ 1⁄Ω¡§ Stud (2)⁄Ω¢-20 ≈ ·Ω¡§ Stud (2)‹Ω•-16 ≈ 1‡Ω¡§ Stud ⁄Ω™-13 ≈ 1 Stud CU-175A CU-250A CU-400A CU-310A CU-400A CU-600A UL UL UL UL UL UL — CSA CSA CSA — CSA Agency Information Series 160, 162, 163 and 165 Ratings: To 620A, 600V; UL Recognized/CSA. See Table. Materials: Molded material: Black, UL rated 94V-0 thermoplastic. Agency Information: UL E62622 General Industrial Class per UL 1059; CSA LR15364. Power Distribution Blocks (600V) Catalog Data Connector Part Line Load Material & Agency Number Connection Connection Ampacity Information *16000 2/0-#8CU-AL 2/0-#8CU-AL AL-175A UL — *16003 250kcmil-#6CU Only 250kcmil-#6CU Only CU-255A UL — *16005 350kcmil-#6CU-AL 350kcmil-#6CU-AL AL-310A UL — 16200 #2-#14CU, #2-#8AL #2-#14CU, #2-#8AL AL-115A UL CSA 16201 1/0-#14CU Only 1/0-#14CU Only CU-150A UL CSA 16204 2/0-#8CU-AL 2/0-#8CU-AL AL-175A UL CSA 16301 250kcmil-#6CU Only 250kcmil-#6CU Only CU-255A UL CSA 16303 350kcmil-#6CU-AL 350kcmil-#6CU-AL AL-310A UL CSA 16306 500kcmil-#6CU-AL 500kcmil-#6CU-AL AL-380A UL CSA (2)350kcmil-#4CU-AL (2)350kcmil-#4CU-AL 16500 AL-620A UL CSA (2)500kcmil-#6CU-AL (2)500kcmil-#6CU-AL 16504 AL-760A UL CSA *160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165) have mounting holes within barriers. See Data Sheet for dimensional drawings. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1117 (Series 160, 162, 165) For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuseblocks, Holders and Terminal Blocks Power Distribution Blocks Input/Output Termination Options Wire Size Basic Part No. 163 Series (Replaces Bussmann 164 Series) Ampere Ratings: up to 420A Voltage Ratings: 600V Construction: UL 94VO. Tin-plated aluminum connectors. Agency Information: UL Recognized: UL E62622 General Industrial Class per UL1059 CSA Certified: CSA LR15364 Optional Covers: 4.14" Supplied with (4) #4 thread-cutting screws assembled as shown Line Side Load Side Amps/ Pole 16301* 250kcmil-#6CU Only 250kcmil-#6CU Only 255 16303 350kcmil-#6CU-AL 350kcmil-#6CU-AL 310 16306 500kcmil-#6CU-AL 500kcmil-#6CU-AL 16321 2/0-#14CU, 2/0-#8AL (6)# 16323 350kcmil-#6CU-AL (6) 16325 2/0-#14CU, 2/0-#8AL (6)# 16330 500kcmil-#6CU-AL (6) 16332 350kcmil-#6CU-AL (3) #2-#14CU, #2-#8AL (2) 1/0-#14CU, 1/0-#8AL 310 16335 500kcmil-#6CU-AL (3) #2-#14CU, #2-#8AL (2) 1/0-#14CU, 1/0-#8AL 380 16370 350kcmil-#6CU-AL (12) 16371 350kcmil-#6CU-AL (6) #2-#14CU, #2-#8AL (3) 1/0-#14CU, 1/0-#8AL 310 16372 350kcmil-#6CU-AL (21) #10-#14CU, #10AL 310 16373 350kcmil-#6CU-AL (14) #10-#14CU, #10AL (3) 1/0-#14CU-AL 310 16375 600kcmil-#2CU-AL (12) 16376 600kcmil-#2CU-AL (6) #2-#14CU, #2-#8AL (3) 1/0-#14CU, 1/0-#8AL 420 16377 (2) 16378 500kcmil-#6CU-AL Stud Size (2) ⁄Ω¢-20 x 1 380 16383 500kcmil-#6CU-AL Stud Size (1) ‹Ω•-16 x 1 380 300kcmil-#4CU-AL 380 4-#14CU, #4-#8AL 175 #4-#14CU, #4-#12AL 310 4-#14CU, #4-#8AL 350 #2-#14CU, #2-#12AL 380 #4-#14CU, #4-#12AL #4-#14CU, #4-#12AL 4-#14CU, #4-#12AL (12) 310 420 570 16390 Stud Size ‹Ω•-16 x 1⁄Ω• Stud Size ‹Ω•-16 x 1⁄Ω• 250 16394 Stud Size ⁄Ω™-13 x 1⁄Ω¡§ Stud Size ⁄Ω™-13 x 1⁄Ω¡§ 400 16395 Stud Size ‹Ω•-16 x 1‡Ω¡§ Stud Size (2) ⁄Ω¢-20 x ·Ω¡§ 310 Textured surface for marking Line/Load *Copper connectors for use with copper wire only. CPDB-1 (single pole) 2.10" CPDB-2 (two pole) 3.72" CPDB-3 (three pole) 5.34" Covers ordered and shipped separately. 1-pole 1.96" 2-pole 3.58" CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 3-pole 5.20" Ordering Information: 163 Series blocks are available in 1, 2 or 3 poles. To order: Basic Part No. + Number of poles Examples: 16301-1 = (one-pole block) 16303-3 = (three-pole block) .31" 3.37" 4.00" .97" 1.62" 3.25" Mtg. hole .21 x .41, c'bore .42 x .62 x .12 deep 3.32" Data Sheet: 1148 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 97 Page 98 Blank (Do NOT Print) Bussmann® Overview for Fusible Disconnect Switches CFD30J3 Catalog number CFD60J3 3 pole General purpose amp rating FD200J3 FD400J3 FD600J3 FD800L3 CFD30CC3 CFD30J3 CFD60J3 CFD100J3 FD200J3 FD400J3 FD600J3 FD800L3 30 30 60 100 200 400 600 800 N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC 600 600 600 600 600 600 600 600 HP HP HP HP 5/7.5 7.5 15 20 5/7.5 7.5 15 20 15 15 30 50 25 30 60 75 50 60 125 150 100/125 125 250 350 150 200 400 500 200 250 500 600 HP HP 2 3 2 3 — — — — — — — — — — — — CC J J J J,T J,T J,T L 1000 1000 750 750 1000 1000 1000 1000 A Approvals1 CFD100J3 CFD30CC3 – FD800L3 2 pole 3 pole 4 pole Technical ratings (UL,CSA) Max operating voltage V Max horsepower rating Three phase 200 – 208V 240V 480V 600V Single phase 120V 240V UL fuse class Technical ratings (IEC) Rated insulation and operational voltage. ac20 and dc202 Rated thermal current, Ith ac 20/dc 20 ac 20/dc 20 open enclosed A A 32 32 32 32 63 63 125 125 250 250 400 400 630 600 800 720 ac 21A ≤500V ≤690V A A 32 32 32 32 63 63 125 125 250 250 400 400 630 630 800 800 14/15 25 14/15 25 30 60 80/90 132 132/140 230 210/230 330 315/340 540 350/380 600 lb lb 1.54 1.98 1.54 1.98 2.86 3.52 3.30 3.96 15.21 17.4 17.2 19.4 37.48 46.3 37.48 46.3 H in W in D in 3.82 4.17 4.21 3.82 4.17 4.21 3.94 5.63 5.04 5.66 7.06 5.09 7.87 10.31 7.83 7.87 11.22 8.11 11.42 14.69 9.21 11.42 14.69 9.21 Rated operational power ac23 400/415V 690V kW kW Physical characteristics Weight Dimension 3 pole switch 4 pole 3 pole Accessories Double break contacts S S S S S S S S Fuse cover S S S • S S S S Terminal lug kit Integral Integral Integral BDTL24 BDTL25 BDTL26 BDTL27 BDTL27 Terminal shroud Not required Not required Not required • • • • • Auxiliary contact • • • • • • • • Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 • • • • • • • • • • • • • • • • Conversion kit 6 pole Transfer Bypass Mechanical interlock • • — • • • — • • • — — • • — — • • • • • • • • • • • • • • • • Electrical interlock — — — — • • • • S = Standard • = Available — = Not available 1 UL listed switches are also CSA approved. 2 1000V IEC 408 UL listed, CSA approved, IEC rated, CE marked For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 99 30A Fusible Disconnect Switches Bussmann® Base & DIN Rail Mounted UL Fuse Class J, CC For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft CFD30J3 + CDS180S + CDH3S 30A Switches, 600V UL General Purpose Amp Rating CFD30J3 3 pole 30 30 4 pole 30 30 IEC Fuse Type 600V 200V J CC 5 5 7.5 7.5 7.5 7.5 15 15 20 20 #18 – 8 #18 – 8 CU CFD30J3 CU CFD30CC3 J CC 5 5 7.5 7.5 7.5 7.5 15 15 20 20 #18 – 8 #18 – 8 CU CFD30J4 CU CFD30CC4 Selector Handles CDH3S, 5S NEMA Type IEC Type Maximum Horsepower Rating Three Phase 208V 240V 480V 600V — For use with shafts Color All marked both O/I & Off/On 1,3R,12 IP65 Black 1,3R,12 IP65 Red/Yellow 1,3R,12 IP65 Black 1,3R,12 IP65 Red/Yellow Terminal Lugs Wire Wire Size Type .20 x .20" ( Catalog Number 5 x 5 mm) Defeatable Padlockable Weight (lbs) Catalog Number — — Yes Yes Yes Yes Yes Yes 0.16 0.16 0.16 0.16 CDH3S CDH4S CDH5S CDH6S .20 x .20" ( 5 x 5 mm) CDH4S, 6S Shafts — For use with CDH selector handles Shaft Length (inches/mm) CDS_ _S 3.3/85 4.1/105 4.7/120 5.1/130 7.1/180 9.8/250 13.0/330 Mounting Depth1 (in inches) 5.5 5.5 5.5 5.5 6.3 9.1 12.2 – 5.7 – 6.5 – 7.1 – 7.5 – 9.4 – 12.2 – 15.4 Weight (lbs.) Catalog Number 0.04 0.04 0.05 0.05 0.08 0.10 0.14 CDS85S CDS105S CDS120S CDS130S CDS180S CDS250S CDS330S For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 100 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Handles & Shafts For 30A Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft CFD30J3 + CDS67P + BDH106 Pistol Handles For use with shafts NEMA Type IEC Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 .20 x .20" ( BDH104, 106 5 x 5 mm) Color Marking Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow BDH105, 107 Length (inches/mm) Defeatable Padlockable Weight (lbs.) Catalog Number 1.8/45 1.8/45 2.6/65 2.6/65 2.6/65 2.6/65 2.6/65 2.6/65 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.28 0.28 0.29 0.29 0.29 0.29 0.29 0.29 BDH104 BDH105 BDH106 BDH107 CDHXB65 CDHXY65 BDH106T BDH107T O/I&Off/On O/I&Off/On O/I&Off/On O/I&Off/On O/I&Off/On O/I&Off/On Off/On/Test Off/On/Test Shafts For use with pistol handles Shaft length (inches/mm) Mounting Depth (in inches) 5.9/150 6.7/170 10.4/265 15.8/400 19.7/500 CDS__ __P .20 x .20" ( 4.9 5.9 9.5 15.0 20.5 – – – – – 8.9 9.7 13.4 18.7 22.6 5 x 5 mm) Weight (lbs.) Catalog Number 0.07 0.08 0.12 0.18 0.23 CDS48P CDS67P CDS49P CDS50P CDS99P 5.20" 132mm BDH79 BDH79 Mounted 5.20"/132mm BDH79 Mounted Depth Direct Mount Handle Mounts directly to switch, no shaft necessary NEMA Type Color Marking Length (Inches/mm) 1 Black O/I/Test 50 Padlockable Yes Weight (lbs.) Catalog Number 0.10 BDH79 For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 101 60A - 100A Bussmann® For Fusible Disconnect Switches UL Fuse Class J For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit CFD60J3 60 — + BDS210 + BDH58 100A Switches, 600V UL General Purpose Amp Rating UL Fuse Type 600V 3 pole 60 100 4 pole 60 100 Maximum Horsepower Rating Three Phase 200V 208V 240V 480V J J 15 25 15 25 15 30 30 60 50 75 J J 15 25 15 25 15 30 30 60 50 75 Pistol Handles — NEMA/UL Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 .24 x .24" ( Catalog Number 600V 3 pole CFD60J3 CFD100J3 4 pole CFD60J4 CFD100J4 6 x 6 mm) IEC Type Color Length (inches/mm) IP65 IP65 IP65 IP65 IP65 IP65 Black Red/Yel Black Red/Yel Black Red/Yel 2.6/65 2.6/65 3.1/80 3.1/80 3.1/80 3.1/80 Shafts BDH58, 60 Marking O/I O/I O/I O/I O/I O/I — & & & & & & .24 x .24" ( BDH59, 61 Padlockable Weight (lbs.) Catalog Number Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.29 0.30 0.30 0.30 0.30 BDH58 BDH59 BDH60 BDH61 CDHXB86 CDHXY86 6 x 6 mm) Mounting Depth (in inches) 5.9/150 8.3/210 11.4/290 14.2/360 16.9/430 5.5 8.0 11.0 13.8 16.5 CFD100J3 Defeatable Off/On Off/On Off/On Off/On Off/On Off/On Shaft Length (inches/mm) BDS__ CFD60J3 – – – – – 8.5 11.0 14.0 16.8 19.7 Weight (lbs.) Catalog Number 0.09 0.13 0.18 0.23 0.27 BDS150 BDS210 BDS290 BDS360 BDS430 Twisted Shafts Rotates handle 45° .24 x .24" ( Shaft Length (inches/mm) Mounting Depth (in inches) 5.1/130 8.3/210 11.4/290 14.2/360 BDST__ 4.8 8.0 11.0 13.8 – – – – 6 x 6 mm) 7.8 11.0 14.0 16.8 Weight (lbs.) Catalog Number 0.08 0.13 0.18 0.23 BDST4 BDST25 BDST29 BDST30 Direct Mount Handle Mounts directly to switch, no shaft necessary NEMA Type Color Marking Length (Inches/mm) 1 Black O/I/Test 50 Padlockable Yes Weight (lbs.) Catalog Number 0.10 CDH4 For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 102 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Accessories For 60A - 100A Fusible Disconnect Switches Terminal Lug Kit BDTL24 For Use On: Wire Size Kit Weight (lbs.) CFD60J_ CFD100J_ #14 – 4 #14 – 2/0 — 0.43 Wire Type CU CU/AL Terminal Lugs Per Kit Catalog Number — 6 Integral BDTL24 Auxiliary Contacts CDAUX10 CDAUX01K Description For Use On: Weight (lbs.) AC Thermal Amp Rating AC Rated Voltage Catalog Number 1 N.O. 1 N.C. CFD60 – CFD100 0.07 0.07 10 10 600 600 CDAUX10 CDAUX01K Replacement Fuse Clip Description Catalog Number For Use On: Removable fuse carrier CFD60 CFC60J CFC60J Replacement Fuse Covers Description Catalog Number For Use On: Transparent fuse cover CFD100 CFCVR100 CFCVR100 Terminal Shroud Description Includes one terminal shroud for line or load side For Use On: Weight (lbs.) Catalog Number CFD100, 1-POLE 0.04 CFTS100 CFTS100 Terminal Poles CFZ1 Description For Use On: Weight (lbs.) AC Thermal Amp Rating AC Rated Voltage Catalog Number Detachable neutral mounts on side of switch or DIN rail CFD60 0.13 63 600 CFZ1 CFD100 0.31 125 600 CFZ2 DIN Rail NDNA100 Description For Use On: WeIght (lbs.) Length (inches/mm) Catalog Number 35mm Aluminum DIN Rail 35mm Aluminum DIN Rail CFD60 CFD60 .38 .75 39.4/1000 78.8/1000 NDNA100 NDNA200 “T” Type Fuse Adapter Kit BDTA1 Description For Use On: Catalog Number 100A, 600V CFD100 BDTA1 For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 103 200A - 800A Bussmann® Fusible Disconnect Switches UL Fuse Class J, T, L For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit FD200J3 + BDS280 + BDH114 + BDTL25 200 — 800A Switches, 600V UL General Purpose Amp Rating 2 pole 200 400 600 800 3 pole 200 400 600 800 4 pole 200 400 600 800 FD400J3 FD600J3 FD800L3 Pistol Handles — NEMA Type 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 IEC Type IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 .47 x .47" ( Color Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Black Red/Yellow Metal UL Fuse Type 600V Maximum Horsepower Rating Three Phase 200V 208V 240V 480V J1 J1 J1 L — — — — — — — — — — — — — — — — — — — — J1 J1 J1 L 50 100 150 200 50 125 150 200 60 125 200 250 125 250 400 500 150 350 500 600 J1 J1 J1 L 50 100 150 200 50 125 150 200 60 125 200 250 125 250 400 500 150 350 500 600 12 x 12 mm) Catalog Number 600V BDH112 2 pole FD200J2 FD400J2 FD600J2 FD800L2 3 pole FD200J3 FD400J3 FD600J3 FD800L3 4 pole FD200J4 FD400J4 FD600J4 FD800L4 BDH113 Length (inches/mm) Marking Defeatable Padlockable Weight (lbs.) Catalog Number 4.9/125 4.9/125 5.7/145 5.7/145 6.9/175 6.9/175 5.7/145 5.7/145 6.9/175 6.9/175 8.7/220 O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On Off/On Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes — Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.39 0.39 0.39 0.39 0.41 0.41 0.39 0.39 0.41 0.41 1.50 BDH112 BDH113 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 CDHXY22 BDH8 1 J type fuse clips are standard. If 600V Type “T” clips are desired, please order a "T" type fuse adapter kit. For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 104 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Accessories For 200A - 800A Fusible Disconnect Switches Shafts — .47 x .47" ( Shaft Length (inches/mm) 12 x 12 mm) Mounting Depth1 (in inches) For use on FD200J_ – FD400J_ 8.7/220 9.8/250 11.0/280 12.8/325 15.6/395 18.3/465 21.1/535 For use on FD600J_ – FD800J_ 9.8/250 11.0/280 12.8/325 15.6/395 18.3/465 21.1/535 BDS_ Weight (lbs.) Catalog Number 7.9 9.1 10.2 12.0 14.8 17.5 20.3 – – – – – – – 12.2 13.4 14.5 16.3 19.1 21.9 24.6 0.61 0.70 0.77 0.90 1.10 1.32 1.54 BDS220 BDS250 BDS280 BDS325 BDS395 BDS465 BDS535 10.0 11.2 13.0 15.8 18.5 21.1 – – – – – – 12.8 14.0 15.8 18.6 21.3 24.1 0.70 0.77 0.90 1.10 1.32 1.54 BDS250 BDS280 BDS325 BDS395 BDS465 BDS535 Twisted Shafts Rotates handle 45° .47 x .47" ( Shaft Length (inches/mm) For use on FD200J_ – FD400J_ 11.0/280 12.8/325 18.3/465 For use on FD600J_ – FD800J_ 11.0/280 12.8/325 18.3/465 BDS_45 12 x 12 mm) Mounting Depth (in inches) Weight (lbs.) Catalog Number 10.2 – 14.5 12.0 – 16.3 17.5 – 21.9 0.77 0.90 1.32 BDS28045 BDS32545 BDS46545 11.2 – 14.0 13.0 – 15.8 18.5 – 21.3 0.77 0.90 1.32 BDS28045 BDS32545 BDS46545 BDTL25 Terminal Lug Kit BDTL26 For Use On: BDTL27 FD200J_ FD200J FD400J_ FD600J – FD800L FD600J_ & FD800L_ Wire Size #6 – (6) #14 – #2 – (12) #14 – (2) #2 – Kit Weight (lbs.) Wire Type Terminal Lugs Per Kit Catalog Number 0.93 0.93 3.50 1.10 4.62 Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al 6 3 6 3 6 BDTL25 BDTL175 BDTL26 BDTL175/400 BDTL27 300 kcmil 6 kcmil 600 kcmil 16–600 kcmil 600 kcmil BDTL175/400 BDTL175 “T” Type Fuse Adapter Kit For Use On: AC Thermal Amp Rating AC Rated Voltage Poles Catalog Number FD200J_ FD400J_ FD600J_ 200 400 600 600 600 600 3 3 3 BDTA2 BDTA4 BDTA6 BDTA 1 Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 105 Overview Bussmann® For Non-Fusible Disconnect Switches CDNF16 - CDNF160 Catalog Number General Purpose Amp Rating Approvals1 CDNF160 CDNF30 CDNF60 CDNF100 CDNF16 CDNF25 CDNF32 3 pole CDNF16 CDNF25 CDNF32 CDNF45 CDNF63 CDNF30 CDNF100 CDNF160 A 16 25 40 60 80 30 60 100 125 2 pole 3 pole 4 pole N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL508 UL508 N/A UL98 UL98 N/A UL98 UL98 N/A UL98 UL98 UL98 UL98 UL98 600 600 600 600 600 600 600 600 600 3 5 10 10 7.5 7.5 15 20 10 10 20 25 15 15 30 30 20 20 40 40 10 10 20 30 20 20 40 40 25 30 50 50 30 30 75 100 1/2 1.5 3/4 2 1 3 2 5 2 5 2 5 3 7.5 5 15 7.5 20 750 750 750 750 750 750 750 750 750 25 25 16 16 32 32 25 25 40 40 32 32 63 63 63 63 80 80 80 80 40 40 40 40 63 63 63 63 115 115 100 100 200 160 160 160 7.5 7.5 9 9 11 11 22 15 37 18.5 15 15 18.5 15 37 37 75 75 0.24 2.68 1.38 2.20 0.24 2.68 1.38 2.20 0.24 2.68 1.38 2.20 0.59 3.60 2.07 2.85 0.59 3.60 2.07 2.85 0.79 3.94 2.76 2.95 0.79 3.94 2.76 2.95 0.79 3.94 2.76 2.95 2.42 5.00 4.96 2.93 Integral • • Integral • • Integral • • Integral • • Integral • • Integral • • Integral • • Integral • • Integral • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • — • — • — • — • • • • • — • • • • — • • • • — • • • • — • • • • — • • • • — • • • • — • • • — — • • • • — Technical Ratings UL,CSA Max operating voltage V Max horsepower rating Three phase 200 – 208V HP 240V HP 480V HP 600V HP Single phase 120V HP 240V HP Technical Ratings IEC Rated insulation and operational voltage. ac20 and dc20 V Rated thermal current, Ith ac 20/dc 20 open A ac 20/dc 20 enclosed A ac 21A 500V A 690V A Rated operational power ac23 400/415V kW 690V kW Physical Characteristics Weight 3 pole lb Dimension 3 pole] H in W in D in Accessories Terminal lug kit Terminal shroud Auxiliary contact Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 Handle type Selector Pistol Conversion kits 6 pole Transfer Bypass Mechanical interlock Electrical interlock • = Available — = Not available 1 UL listed switches are also CSA approved. CDNF60 UL listed, CSA approved, IEC rated, CE marked For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 106 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Overview For Non-Fusible Disconnect Switches BDNF200A - BDNF3150 BDNF175A Catalog Number General Purpose Amp Rating Approvals1 BDNF200A 3 pole A 2 pole 3 pole 4 pole Technical Ratings UL, CSA Max operating voltage V Max horsepower rating Three phase 200 – 208V HP 240V HP 480V HP 600V HP Single phase 120V HP 240V HP Technical Ratings IEC Rated insulation and operational voltage. ac20 and dc20 V Rated thermal current, Ith ac 20/dc 20 open A ac 20/dc 20 enclosed A ac 21A 500V A 690V A Rated operational power ac23 400/415V kW 690V kW Physical Characteristics Weight 3 pole lb Dimension 3 pole H in W in D in Accessories Terminal lug kit Terminal shroud Auxiliary contact Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 Handle type Selector Pistol Conversion kits 6 pole Transfer Bypass Mechanical interlock Electrical interlock BDNF400A BDNF600A BDNF800A BDNF1200 BDNF1600 BDNF2000 BDNF3150 BDNF175A BDNF200A BDNF400 BDNF600A BDNF800A BDNF1200 BDNF1600 BDNF2000 175 200 400 600 800 UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC IEC UL98 & IEC UL98 & IEC IEC 1200 1600 UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC IEC 2000 BDNF3150 3150 UL98 & IEC UL98 & IEC IEC IEC IEC IEC 600 600 600 600 600 600 600 600 600 30 40 75 100 60 75 150 200 100 125 250 350 150 200 400 500 200 250 500 600 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1000 1000 1000 1000 1000 1000 1000 1000 1000 200 200 200 200 315 270 250 250 630 630 630 630 800 720 800 800 1250 1250 1250 1250 1600 1600 1600 1600 2500 2300 2500 2500 2500 2300 2500 2500 3150 2600 3150 3150 90 170 132 200 315 355 355 355 400 — 400 — 400 — 400 — 400 — 6.61 8.35 7.83 4.55 6.61 8.35 8.62 4.55 13.66 11.81 10.24 5.12 13.66 11.77 11.93 5.12 35.9 19.09 14.29 4.92 38.55 19.09 14.29 4.92 127.7 25.04 18.43 10.67 127.7 25.04 18.43 10.67 127.7 25.04 18.43 10.67 BDTL25 • • BDTL25 • • BDTL26 • • BDTL27 • • BDTL30 • • BDTL28 • • BDTL28 — • BDTL28/2 — • BDTL28/2 — • • • • • • • • • • • • • • • • • • • — • — • — • — • — • — • — • — • — • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • — — — • • — — — • • — — — • • S = Standard feature • = Available — = Not available 1 UL listed switches are also CSA approved. UL listed, CSA approved, IEC rated, CE marked For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 107 16A - 100A Bussmann® For Non-Fusible Disconnect Switches Base & DIN Rail Mounted For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft CDNF63 + CDS85S + CDH3S 16 — 100 Amp Switches, 600V, 3 Pole1 CDNF16 CDNF25 CDNF32 CDNF30 CDNF60 CDNF100 UL General Purpose Amp Rating IEC AC21 Amp Rating 16 25 40 60 80 30 60 100 16 25 40 63 80 40 63 115 Maximum Horsepower Rating Single Phase 120V 240V 1/2 3/4 1 2 2 2 3 5 Selector Handles NEMA Type I ON O OFF CDH1S CDH15S CDH6S IEC Type 1.5 2 3 5 5 5 7.5 15 5 7.5 10 15 20 10 20 30 10 15 20 30 40 20 40 50 10 20 25 30 40 30 40 50 — For use with shafts Color All marked both O/I & Off/On 1 IP54 Black 1 IP54 Red/Yellow 1 IP54 Black 1 IP54 Red/Yellow 1,3R,12 IP65 Black 1,3R,12 IP65 Red/Yellow 1,3R,12 IP65 Black 1,3R,12 IP65 Red/Yellow Shafts Terminal Lugs Three Phase 240V 480V 600V Wire Size Wire Type Catalog Number #18 – 8 #18 – 8 #18 – 8 #14 – 4 #14 – 1 #14 – 4 #14 – 4 #8 – 1/0 CU CU CU CU CU CU CU CU CDNF16 CDNF25 CDNF32 CDNF45 CDNF63 CDNF30 CDNF60 CDNF100 .20 x .20" ( 5 x 5 mm) Defeatable Padlockable Weight (lbs) Catalog Number — — — — — — Yes Yes — — Yes Yes Yes Yes Yes Yes 0.09 0.09 0.12 0.12 0.16 0.16 0.16 0.16 CDH1S2 CDH2S2 CDH15S2 CDH16S2 CDH3S CDH4S CDH5S CDH6S — For use with CDH selector handles .20 x .20" ( 5 x 5 mm) Mounting depth3 in inches Shaft Length (inches /mm) CDS_ S 3.3/85 4.1/105 4.7/120 5.1/130 7.1/180 9.8/250 13/330 CDNF16 CDNF25 CDNF32 CDH1S CDH2S CDH15S CDH16S 4.2 5.0 5.6 6.0 7.1 10.7 13.8 – – – – – – – 5.0 5.8 6.4 6.7 8.7 11.5 14.6 CDNF45 CDNF63 CDH3S CDH4S CDH5S CDH6S 3.6 4.4 5.0 5.4 7.4 10.1 13.3 – – – – – – – 4.3 5.1 5.8 6.1 8.1 10.8 14.0 CDH1S CDH2S CDH15S CDH16S 4.9 5.7 6.3 6.7 8.6 11.4 14.6 – – – – – – – 5.6 6.4 7.0 7.4 9.4 12.1 15.3 CDNF30 CDNF60 CDNF100 CDH3S CDH4S CDH5S CDH6S CDH3S CDH4S CDH5S CDH6S 4.4 5.1 5.7 6.1 8.1 10.9 14.0 – – – – – – – 5.0 5.8 6.4 6.8 8.7 11.5 14.7 3.9 4.7 5.3 5.6 7.6 10.4 13.5 – – – – – – – 4.9 5.7 6.3 6.7 8.6 11.4 14.5 Weight (lbs.) Catalog Number 0.04 0.04 0.05 0.05 0.08 0.10 0.14 CDS85S CDS105S CDS120S CDS130S CDS180S CDS250S CDS330S 1 A snap on fourth pole may be added 2 Not suitable for use with CDNF30, 60, 100. 3 Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length. For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 108 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Handles & Shafts For 16A-100A Non-Fusible Disconnect Switches Base & DIN Rail Mounted Pistol Handles NEMA Type BDH104, 106 BDH107 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12,4,4X 1,3R,12,4,4X Shafts — For use with shafts IEC Type Color IP65 IP65 IP65 IP65 IP66 IP66 Black Red/Yel Black Red/Yel Black Red/Yel Marking O/I O/I O/I O/I O/I O/I & & & & & & .20 x .20" ( 5 x 5 mm) Length (inches/mm) Defeatable Padlockable Weight (lbs.) Catalog Number 1.8/45 1.8/45 2.6/65 2.6/65 2.6/65 2.6/65 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.28 0.28 0.29 0.29 0.29 0.29 BDH104 BDH105 BDH106 BDH107 CDHXB65 CDHXY65 Off/On Off/On Off/On Off/On Off/On Off/On — For use with pistol handles .20 x .20" ( 5 x 5 mm) Mounting depth1 in inches Shaft Length (inches/mm) CDS_P CDNF16 CDNF25 CDNF32 5.9/150 6.7/170 10.4/265 15.8/400 19.7/500 6.2 7.0 10.7 16.0 20.0 – – – – – 6.7 7.5 11.3 16.6 20.5 CDNF45 CDNF63 6.9 7.7 11.4 16.8 20.7 – – – – – 7.4 8.1 11.9 17.2 21.1 CDNF30 CDNF60 CDNF100 6.4 7.2 10.9 16.2 20.1 – – – – – 7.4 8.1 11.9 17.2 21.1 Weight (lbs.) Catalog Number 0.07 0.08 0.12 0.18 0.23 CDS48P CDS67P CDS49P CDS50P CDS99P Weight (lbs.) Catalog Number 0.07 0.08 0.12 0.18 CDS48T CDS67T CDS49T CDS50T Twisted Shafts Rotates handle 45° .20 x .20" ( 5 x 5 mm) Mounting depth1 in inches CDS_T Shaft Length (inches/mm) CDNF16 CDNF25 CDNF32 5.9/150 6.7/170 10.4/265 15.8/400 6.2 7.0 10.7 16.0 – – – – 6.7 7.5 11.3 16.6 CDNF45 CDNF63 6.9 7.7 11.4 16.8 – – – – 7.4 8.1 11.9 17.2 CDNF30 CDNF60 CDNF100 6.4 7.2 10.9 16.2 – – – – Replacement Knob OPMRH Mounts directly to switch; no shaft necessary CDBY68419/1 NEMA Type 1 1 1 Metal collar Set screw Color Red Red Red For Use On: CDNF16, 25, 32 CDNF30, 45, 60, 63,100 CDNF30, 45, 60, 63,100 CDNF16 – CDNF100 CDNF16, 25, 30, 32, 45, 60, 63, 100 7.4 8.1 11.9 17.2 Length (inches) 1.0 1.4 1.6 — — CDBY68306 Padlockable — — Yes2 — — Catalog Number OPMRH CDBY683063 CDBY68419/13 CDMC1 CDSWM5X8 CDMC1 1 Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length. 2 .1875" (3/16") diameter shackle required. 3 Set screw CDSWM5X8 needed with replacement knobs CDBY__. For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 109 16A - 100A Bussmann® Non-Fusible Disconnect Switches Door Mounted For a complete assembly, please select one of each: 1 switch 1 handle CDNF45D CDH9S 16 — 100 Amp Switches, 600V, 3 Pole123 UL General Purpose Amp Rating 16 25 40 604 804 304 604 1004 CDNF16D CDNF25D CDNF32D CDH8S CDH12S O OFF CDH17S CDH19S CDH9S CDH13S 16 25 40 63 80 40 63 115 Maximum Horsepower Rating Single Phase Three Phase 120V 240V 240V 480V 600V 1/2 3/4 1 2 2 2 3 5 1.5 2 3 5 5 5 7.5 15 5 7.5 10 15 20 10 20 30 10 15 20 30 40 20 40 50 10 20 25 30 40 30 40 50 Terminal Lugs Wire Wire Size Type #18 – 8 #18 – 8 #18 – 8 #14 – 4 #14 – 1 #14 – 4 #14 – 4 #8 – 1/0 Catalog Number CU CU CU CU CU CU CU CU CDNF16D CDNF25D CDNF32D CDNF45D CDNF63D CDNF30D CDNF60D CDNF100D Selector Handles NEMA/UL Type I ON IEC AC21 Amp Rating IEC Type Color Defeatable Padlockable All marked both O/I & Off/On Snap-on mounting — for use on CDNF16, 25, 32D 1 IP54 Black — — 1 IP54 Red/Yellow — — 1 IP54 Black — Yes 1 IP54 Red/Yellow — Yes 1,3R,12 IP65 Black — Yes 1,3R,12 IP65 Red/Yellow — Yes Screw mounting — for use on CDNF16, 32, 45 & 63D 1 IP54 Black — — 1 IP54 Red/Yellow — — 1 IP54 Black — Yes 1 IP54 Red/Yellow — Yes 1,3R,12 IP65 Black — Yes 1,3R,12 IP65 Red/Yellow — Yes Weight (lbs) Catalog Number 0.10 0.10 0.13 0.13 0.17 0.17 CDH7S CDH8S CDH19S CDH20S CDH9S CDH10S 0.11 0.11 0.14 0.14 0.18 0.18 CDH11S CDH12S CDH17S CDH18S CDH13S CDH14S Door mounted switches do not provide door interlock CDH10S CDH14S Pistol Grip Handle Adapter Description Adapter piece for pistol grip handle 1 2 3 4 For Use On: CDNF30, CDNF60, CDNF100 Weight (lbs) Catalog Number 0.18 CDHZX6 A snap on fourth pole may be added Door mounted switches do not require shafts. CDNF16, 25, 32, 45 & 63 door mounted switches will not accept pistol handles. CDNF45 & 63 door mounted switches can only use screw mounted handles. For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006 110 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® 400A – 800A Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit BDH116 BDS280 BDNF400 BDTL26 400 – 800 Amp switches, 600V BDNF600A BDNF800A BDH112-117 UL general purpose amp rating 2 pole 400 600 800 3 pole 400 600 800 4 pole 400 600 — IEC AC21 amp rating Maximum horsepower rating 200V 208V 240V 480V 600V 630 800 1250 — — — — — — — — — — — — — — — BDNF4002 BDNF600A2 BDNF800A2 630 800 1250 100 150 200 100 150 200 125 200 250 250 400 500 350 500 600 BDNF400 BDNF600A BDNF800A 630 800 1250 100 150 200 100 150 200 125 200 250 250 400 500 350 500 600 BDNF4004 BDNF600A4 BDNF800A4 Pistol handles — for use with shafts NEMA type IEC type Color Length in/mm Marking 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 IP65 IP65 IP65 IP65 IP65 IP65 IP66 IP66 IP66 IP65 Blk R/Y Blk R/Y Blk R/Y Blk R/Y Blk Metal 4.9/125 4.9/125 5.7/145 5.7/145 6.9/175 6.9/175 5.7/145 5.7/145 6.9/175 8.7/220 O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On O/I & Off/On Off/On Shafts — for use with pistol handles BDS280 Shaft length inches/mm 11.0/280 12.8/325 15.6/395 18.3/465 21.1/535 .47 x .47” ( .47 x .47" ( Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Weight (lbs) 0.77 0.90 1.10 1.32 1.54 .47 x .47" ( Mounting depth1 in inches 10.2 – 14.5 12.0 – 16.3 17.5 – 21.9 Weight (lbs) Catalog number 0.39 0.39 0.39 0.39 0.41 0.41 0.39 0.39 0.41 1.50 BDH112 BDH113 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 BDH8 12 x 12 mm) Mounting depth1 in inches 10.2 – 14.5 12.0 – 16.3 14.8 – 19.1 17.5 – 21.9 20.3 – 24.6 Twisted shafts — Rotates handle 45° Shaft length inches/mm 11.0/280 12.8/325 18.3/465 12 x 12 mm) Defeatable Padlockable Yes Yes Yes Yes Yes Yes Yes Yes Yes — Catalog number Catalog number BDS280 BDS325 BDS395 BDS465 BDS535 12 x 12 mm) Weight (lbs) 0.77 0.90 1.32 Catalog number BDS28045 BDS32545 BDS46545 BDS_45 1 Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 111 Accessories Bussmann® for 400A – 800A Non-Fusible Disconnect Switches Terminal lug kits For use on: BDTL26 BDTL30 BDTL27 BDTL175/400 Wire size BDNF400 BDNF400 BDNF600A BDNF800A BDNF800A1 BDNF400 – BDNF600A1 #2 (2) #2 (2) #2 (2) #2 (8) 2/0 (12) #14 Auxiliary contacts 2 – – – – + – 600 kcmil 500 kcmil 600 kcmil 600 kcmil (2)#2 600 kcmil 6 Description For use on: 1 N.O. + 1 N.C. 2 N.O. + 2 N.C. 4 N.O. + 4 N.C 2 N.O. 4 N.O. 8 N.O. BDNF400 – BDNF800A Kit weight (lbs.) Wire type Terminal lugs per kit Kit catalog number 3.50 4.62 4.62 6.90 6.90 1.10 CU/AL CU/AL CU/AL CU/AL CU/AL CU/AL 6 6 6 6 3 3 BDTL26 BDTL262 BDTL27 BDTL30 BDTL32 BDTL175/400 Weight (lbs) 0.20 0.26 0.40 0.18 0.25 0.40 ac thermal amp rating 10 10 10 10 10 10 Weight (lbs) ac thermal amp rating ac rated voltage Catalog number 1.04 400 600 BDZX85 ac rated voltage 600 600 600 600 600 600 Catalog number BDAUX1 BDAUX2 BDAUX3 BDAUX4 BDAUX5 BDAUX6 BDTL32 Terminal poles Description For use on: Detachable neutral mounts on side of switch or DIN rail BDNF400 – BDNF600A BDAUX1-6 Terminal shrouds Description For use on: Weight (lbs) Catalog number Includes one shroud for line or load side BDNF400 BDNF600A BDNF800A 0.62 0.66 0.88 BDTS4 BDTS6A BDTS8A BDZX85 Handle support bracket Description For use on: Weight (lbs) Catalog number Allows handle to be directly mounted to switch behind the door BDNF400 – BDNF600A BDNF800A 0.51 BDZX73 0.88 BDZX71 BDTS_ 1 A load side distribution lug eliminates the need to purchase, install and wire a separate distribution block. 2 UL File E57057 BDZX71 For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 112 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Enclosed Fusible Disconnect Switches 30A – 800A EFJ30X-3PB6 3 Pole1, 600V, 30A – 3150A UL General purpose amp rating 30 30 60 100 200 400 600 800 1 Catalog number EFJ301-3PB6 EFC301-3PB6 EFJ601-3PB6 EFJ1001-3PB8 EFJ2001-3PB4 EFJ4001-3PB4 EFJ6001-3PB4 EFL8001-3PB4 Fuse Type J CC J2 J2 J2 J2 J2 J2 NEMA / UL Enclosure type 3R 4 Catalog Catalog number number EFJ303-3PB6 EFJ304-3PB6 EFC303-3PB6 EFC304-3PB6 EFJ603-3PB6 EFJ604-3PB8 EFJ1003-3PB8 EFJ1004-3PB8 EFJ2003-3PB4 EFJ2004-3PB4 EFJ4003-3PB4 EFJ4004-3PB4 EFJ6003-3PB4 EFJ6004-3PB4 EFL8003-3PB4 EFL8004-3PB4 4X Stainless Catalog number EFJ30X-3PB6 EFC30X-3PB6 EFJ60X-3PB8 EFJ100X-3PB8 EFJ200X-3PB4 EFJ400X-3PB4 EFJ600X-3PB4 EFL800X-3PB4 Switch ratings UL general purpose amp rating 30 60 100 200 400 600 800 Maximum horsepower rating Single phase Three phase 120V 200V 240V 200V 208V 240V 480V 2 3 5 — — — — 3 7.5 10 — — — — 5 10 15 — — — — 5 15 25 50 100 150 200 7.5 15 25 50 125 150 200 7.5 15 30 60 125 200 250 15 30 60 125 250 400 500 Wire size for terminal lugs For wire type Approval1 600V 20 50 75 150 350 500 600 #18 #14 #14 #6 #2 (2) #2 (2) #2 – – – – – – – 8 4 2/0 300 600 600 600 kcmil kcmil kcmil kcmil CU CU CU/AL CU/AL CU/AL CU/AL CU/AL CSA, CSA, CSA, CSA, CSA, CSA, CSA, UL UL UL UL UL UL UL 1 Fusible switches are UL listed to the UL98 standard. 2 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T." For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 113 Enclosed Fusible Disconnect Switches Bussmann® 30A – 800A EFJ607-3P 3 Pole1, 600V, 30A – 3150A UL General purpose amp rating 30 30 60 100 200 400 600 800 4X Plastic Catalog number EFJ30P-3PB6 EFC30P-3PB6 EFJ60P-3PB8 EFJ100P-3PB8 EFJ200P-3PB4 EFJ400P-3PB4 EFJ600P-3PB4 EFL800P-3PB4 Fuse Type J CC J2 J2 J2 J2 J2 J2 NEMA / UL Enclosure type 12 Catalog number EFJ302-3PB6 EFC302-3PB6 EFJ602-3PB6 EFJ1002-3PB8 EFJ2002-3PB4 EFJ4002-3PB4 EFJ6002-3PB4 EFL8002-3PB4 7&9 Catalog number EFJ307-3PB EFC307-3PB EFJ607-3PB EFJ1007-3PB EFJ2007-3PB EFJ4007-3PB EFJ6007-3PB EFL8007-3PB Handle ratings Amperage range 30 60 – 100 200 – 800 1 2 Style type Selector Selector Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol NEMA Color Marking Defeatable Padlockable 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R 4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Black Red/Yel Metal 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On 0/I & Off/On Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Catalog number suffix BJ YJ B6 Y6 B6 Y6 B6 Y6 B8 Y8 B8 Y8 B4 Y4 B7 Y7 B4 Y4 B7 Y7 8 Catalog number CDH5S CDH6S BDH106 BDH107 CDHXB65 CDHXY65 BDH58 BDH59 BDH60 BDH61 CDHXB86 CDHXY86 BDH114 BDH115 BDH116 BDH117 CDHXB12 CDHXY12 CDHXB22 CDHXY22 BDH8 Fusible switches are UL listed to the UL98 standard. 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T." For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 114 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Other Configurations for Enclosed Fusible Disconnect Switches UL general purpose amp rating 30 (J fuses) 30 (CC fuses) 60 100 200 400 600 800 2 Pole Type of Switch 4 Pole1 6 Pole Transfer Bypass Mech. interlock 4 Pole1 6 Pole Transfer Bypass Mech. interlock 4 Pole1 6 Pole Transfer Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 30A – 800A 1 NEMA Enclosure type 3R 4 4X Stainless Catalog number Catalog number Catalog number Catalog number EFJ301-4PB6 EFJ301-6PB6 EFJ301-3TB8 EFJ301-3BB6 EFJ301-3MB6 EFC301-4PB6 EFC301-6PB6 EFC301-3TB8 EFC301-3BB6 EFC301-3MB6 EFJ601-4PB6 EFJ601-6PB4 EFJ601-3TB8 EFJ601-3MB6 EFJ1001-2PB8 EFJ1001-4PB8 EFJ1001-6PB4 EFJ1001-3TB8 EFJ1001-3MB8 EFJ2001-2PB8 EFJ2001-4PB4 EFJ2001-6P8 EFJ2001-3TB4 EFJ2001-3B6 EFJ2001-3MB4 EFJ4001-2PB4 EFJ4001-4PB4 EFJ4001-6P8 EFJ4001-3TB4 EFJ4001-3B6 EFJ4001-3MB4 EFJ6001-2PB4 EFJ6001-4PB4 EFJ6001-6P8 EFJ6001-3TB4 EFJ6001-3B6 EFJ6001-3MB4 EFL8001-2PB4 EFL8001-4PB4 EFL8001-6P8 EFL8001-3TB4 EFL8001-3B6 EFL8001-3MB4 EFJ303-4PB6 EFJ303-6PB6 EFJ303-3TB8 EFJ303-3BB6 EFJ303-3MB6 EFC303-4PB6 EFC303-6PB6 EFC303-3TB8 EFC303-3BB6 EFC303-3MB6 EFJ603-4PB6 EFJ603-6PB4 EFJ603-3TB8 EFJ603-3MB6 EFJ1003-2PB8 EFJ1003-4PB8 EFJ1003-6PB4 EFJ1003-3TB8 EFJ1003-3MB8 EFJ2003-2PB8 EFJ2003-4PB4 EFJ2003-6P8 EFJ2003-3TB4 EFJ2003-3B6 EFJ2003-3MB4 EFJ4003-2PB4 EFJ4003-4PB4 EFJ4003-6P8 EFJ4003-3TB4 EFJ4003-3B6 EFJ4003-3MB4 EFJ6003-2PB4 EFJ6003-4PB4 EFJ6003-6P8 EFJ6003-3TB4 EFJ6003-3B6 EFJ6003-3MB4 EFL8003-2PB4 EFL8003-4PB4 EFL8003-6P8 EFL8003-3TB4 EFL8003-3B6 EFL8003-3MB4 EFJ304-4PB6 EFJ304-6PB6 EFJ304-3TB8 EFJ304-3BB6 EFJ304-3MB6 EFC304-4PB6 EFC304-6PB6 EFC304-3TB8 EFC304-3BB6 EFC304-3MB6 EFJ604-4PB6 EFJ604-6PB4 EFJ604-3TB8 EFJ604-3MB6 EFJ1004-2PB8 EFJ1004-4PB8 EFJ1004-6PB4 EFJ1004-3TB8 EFJ1004-3MB8 EFJ2004-2PB8 EFJ2004-4PB4 EFJ2004-6P8 EFJ2004-3TB4 EFJ2004-3B6 EFJ2004-3MB4 EFJ4004-2PB4 EFJ4004-4PB4 EFJ4004-6P8 EFJ4004-3TB4 EFJ4004-3B6 EFJ4004-3MB4 EFJ6004-2PB4 EFJ6004-4PB4 EFJ6004-6P8 EFJ6004-3TB4 EFJ6004-3B6 EFJ6004-3MB4 EFL8004-2PB4 EFL8004-4PB4 EFL8004-6P8 EFL8004-3TB4 EFL8004-3B6 EFL8004-3MB4 4 Pole EFJ30X-4PB6 EFJ30X-6PB EFJ30X-3TB8 EFJ30X-3BB6 EFJ30X-3MB6 EFC30X-4PB6 EFC30X-6PB6 EFC30X-3TB8 EFC30X-3BB6 EFC30X-3MB6 EFJ60X-4PB6 EFJ60X-6PB4 EFJ60X-3TB8 EFJ60X-3MB6 EFJ100X-2PB8 EFJ100X-4PB8 EFJ100X-6PB4 EFJ100X-3TB8 EFJ100X-3MB8 EFJ200X-2PB8 EFJ200X-4PB4 EFJ200X-6P8 EFJ200X-3TB4 EFJ200X-3B6 EFJ200X-3MB4 EFJ400X-2PB4 EFJ400X-4PB4 EFJ400X-6P8 EFJ400X-3TB4 EFJ400X-3B6 EFJ400X-3MB4 EFJ600X-2PB4 EFJ600X-4PB4 EFJ600X-6P8 EFJ600X-3TB4 EFJ600X-3B6 EFJ600X-3MB4 EFL800X-2PB4 EFL800X-4PB4 EFL800X-6P8 EFL800X-3TB4 EFL800X-3B6 EFL800X-3MB4 6 Pole 2 1 2 IEC rated only. = Three poles For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 115 Bussmann® Other Configurations for Enclosed Fusible Disconnect Switches UL General purpose amp rating 30 (J fuses) 30 (CC fuses) 60 100 200 400 600 800 Type of Switch 4 Pole1 6 Pole Transfer Bypass Mech. interlock 4 Pole1 6 Pole Transfer Bypass Mech. interlock 4 Pole1 6 Pole Transfer Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 2 Pole1 4 Pole1 6 Pole Transfer Bypass Mech. interlock 4X Plastic NEMA Enclosure type 12 7&9 Catalog number Catalog number Catalog number EFJ30P-4PB6 EFJ30P-6PB6 EFJ30P-3TB8 EFJ30P-3BB6 EFJ30P-3MB6 EFC30P-4PB6 EFC30P-6PB6 EFC30P-3TB8 EFC30P-3BB6 EFC30P-3MB6 EFJ60P-4PB6 EFJ60P-6PB4 EFJ60P-3TB8 EFJ60P-3MB6 EFJ100P-2PB8 EFJ100P-4PB8 EFJ100P-6PB4 EFJ100P-3TB8 EFJ100P-3MB8 EFJ200P-2PB8 EFJ200P-4PB4 EFJ200P-6P8 EFJ200P-3TB4 EFJ200P-3B6 EFJ200P-3MB4 EFJ400P-2PB4 EFJ400P-4PB4 EFJ400P-6P8 EFJ400P-3TB4 EFJ400P-3B6 EFJ400P-3MB4 EFJ600P-2PB4 EFJ600P-4PB4 EFJ600P-6P8 EFJ600P-3TB4 EFJ600P-3B6 EFJ600P-3MB4 EFL800P-2PB4 EFL800P-4PB4 EFL800P-6P8 EFL800P-3TB4 EFL800P-3B6 EFL800P-3MB4 EFJ302-4PB6 EFJ302-6PB6 EFJ302-3TB8 EFJ302-3BB6 EFJ302-3MB6 EFC302-4PB6 EFC302-6PB6 EFC302-3TB8 EFC302-3BB6 EFC302-3MB6 EFJ602-4PB6 EFJ602-6PB4 EFJ602-3TB8 EFJ602-3MB6 EFJ1002-2PB8 EFJ1002-4PB8 EFJ1002-6PB4 EFJ1002-3TB8 EFJ1002-3MB8 EFJ2002-2PB8 EFJ2002-4PB4 EFJ2002-6P8 EFJ2002-3TB4 EFJ2002-3B6 EFJ2002-3MB4 EFJ4002-2PB4 EFJ4002-4PB4 EFJ4002-6P8 EFJ4002-3TB4 EFJ4002-3B6 EFJ4002-3MB4 EFJ6002-2PB4 EFJ6002-4PB4 EFJ6002-6P8 EFJ6002-3TB4 EFJ6002-3B6 EFJ6002-3MB4 EFL8002-2PB4 EFL8002-4PB4 EFL8002-6P8 EFL8002-3TB4 EFL8002-3B6 EFL8002-3MB4 Bypass Transfer 30A – 800A 2 2 2 2 2 2 2 2 Mechanical Interlock 3 3 3 1 2 3 IEC rated only. Consult factory for pricing and availability. = Three poles For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 116 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Enclosed Non-Fusible Disconnect Switches 16A – 3150A ENF321-3PBJ ENF63X-3PB6 3 Pole, 600V, 16A – 100A — Selector handle NEMA Enclosure type UL general purpose amp rating 16 25 40 60 80 1 3R Catalog number Catalog number ENF161-3PBJ ENF251-3PBJ ENF321-3PBJ ENF451-3PBJ ENF631-3PBJ 41 Selector handles are only NEMA rated 1, 3R, 12 Catalog number ENF163-3PBJ ENF253-3PBJ ENF323-3PBJ ENF453-3PBJ ENF633-3PBJ ENF164-3PBJ ENF254-3PBJ ENF324-3PBJ ENF454-3PBJ ENF634-3PBJ 1 4X Stainless1 Selector handles are only NEMA rated 1, 3R, 12 Catalog number ENF16X-3PBJ ENF25X-3PBJ ENF32X-3PBJ ENF45X-3PBJ ENF63X-3PBJ 3 Pole, 600V, 16A – 3150A — Pistol handle NEMA Enclosure type UL 98 UL 508 1 1 2 UL general purpose amp rating 16 25 40 60 80 30 60 100 125 200 400 600 800 1200 1600 2000 31502 Catalog number ENF161-3PB6 ENF251-3PB6 ENF321-3PB6 ENF451-3PB6 ENF631-3PB6 ENF301-3PB6 ENF601-3PB6 ENF1001-3PB6 ENF1251-3PB6 ENF2001-3PB8 ENF4001-3PB4 ENF6001-3PB4 ENF8001-3PB4 ENF12001-3PB4 ENF16001-3P8 ENF20001-3P8 ENF31501-3P8 3R Catalog number ENF163-3PB6 ENF253-3PB6 ENF323-3PB6 ENF453-3PB6 ENF633-3PB6 ENF303-3PB6 ENF603-3PB6 ENF1003-3PB6 ENF1253-3PB6 ENF2003-3PB8 ENF4003-3PB4 ENF6003-3PB4 ENF8003-3PB4 ENF12003-3PB4 ENF16003-3P8 ENF20003-3P8 ENF31503-3P8 4 Catalog number ENF164-3PB6 ENF254-3PB6 ENF324-3PB6 ENF454-3PB6 ENF634-3PB6 ENF304-3PB6 ENF604-3PB6 ENF1004-3PB6 ENF1254-3PB6 ENF2004-3PB8 ENF4004-3PB4 ENF6004-3PB4 ENF8004-3PB4 ENF12004-3PB4 ENF16004-3P8 ENF20004-3P8 ENF31504-3P8 4X Stainless Catalog number ENF16X-3PB6 ENF25X-3PB6 ENF32X-3PB6 ENF45X-3PB6 ENF63X-3PB6 ENF30X-3PB6 ENF60X-3PB6 ENF100X-3PB6 ENF125X-3PB6 ENF200X-3PB8 ENF400X-3PB4 ENF600X-3PB4 ENF800X-3PB4 ENF1200X-3PB4 ENF1600X-3P8 ENF2000X-3P8 ENF3150X-3P8 Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12. The overall NEMA rating of an enclosed switch with a selector handle is 1, 3R, 12. IEC rated only. For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 117 Enclosed Non-Fusible Disconnect Switches Bussmann® 16A – 3150A ENF25P-3PY6 ENF252-3PYJ ENF16E-3PBJ ENF45E-3PBJ 3 Pole, 600V, 16A – 100A — Selector handle NEMA Enclosure type 4X Plastic1 Selector handles are only NEMA rated 1, 3R, 12 UL general purpose amp rating 16 25 40 60 80 Catalog number ENF16P-3PBJ ENF25P-3PBJ ENF32P-3PBJ ENF45P-3PBJ ENF63P-3PBJ 12 Catalog number ENF162-3PBJ ENF252-3PBJ ENF322-3PBJ ENF452-3PBJ ENF632-3PBJ IEC Enclosure type 7&9 Catalog number — — — — — IP65 Plastic Catalog number ENF16E-3PBJ ENF25E-3PBJ ENF32E-3PBJ ENF45E-3PBJ ENF63E-3PBJ 3 Pole, 600V, 16A – 3150A — Pistol handle NEMA Enclosure type UL 98 UL 508 4X Plastic UL general purpose amp rating 16 25 40 60 80 30 60 100 125 200 400 600 800 1200 1600 2000 31502 NOTE: EXAMPLE: 1 2 Catalog number ENF16P-3PB6 ENF25P-3PB6 ENF32P-3PB6 ENF45P-3PB6 ENF63P-3PB6 ENF30P-3PB6 ENF60P-3PB6 ENF100P-3PB6 ENF125P-3PB6 ENF200P-3PB8 ENF400P-3PB4 ENF600P-3PB4 ENF800P-3PB4 ENF1200P-3PB4 ENF1600P-3P8 ENF2000P-3P8 ENF3150P-3P8 12 Catalog number ENF162-3PB6 ENF252-3PB6 ENF322-3PB6 ENF452-3PB6 ENF632-3PB6 ENF302-3PB6 ENF602-3PB6 ENF1002-3PB6 ENF1252-3PB6 ENF2002-3PB8 ENF4002-3PB4 ENF6002-3PB4 ENF8002-3PB4 ENF12002-3PB4 ENF16002-3P8 ENF20002-3P8 ENF31502-3P8 IEC Enclosure type 7&9 Catalog number ENF167-3P ENF257-3P ENF327-3P ENF457-3P ENF637-3P ENF307-3P ENF607-3P ENF1007-3P ENF1257-3P ENF2007-3P ENF4007-3P ENF6007-3P ENF8007-3P ENF12007-3P ENF16007-3P ENF20007-3 ENF31507-3P IP65 Plastic Catalog number ENF16E-3PB4 ENF25E-3PB4 ENF32E-3PB4 ENF45E-3PB4 ENF63E-3PB4 ENF30E-3PB6 ENF60E-3PB6 ENF100E-3PB6 ENF125E-3PB6 — — — — — — — — All enclosed switches are provided with a black handle; however, most handles can be substituted with a red and yellow handle if desired. Please substitute the handle suffix code (2nd and 3rd from last characters) with the red/yellow handle catalog number suffix from page 3.12. There is no additional price adder for changing to a red/yellow handle of equal ratings and style. A red/yellow selector handle for an ENF161-3PBJA can be substituted for the black selector handle by using the "YJ" suffix instead of the "BJ" suffix, new catalog #ENF161-3PYJA. Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12. The overall NEMA rating of an enclosed switch with a selector handle is 1, 3R, 12. IEC rated only. For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 118 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Enclosed Non-Fusible Disconnect Switches 16A – 400A UL General purpose amp rating Other Configurations NEMA Enclosure type 4 Catalog number 1 Catalog number 3R Catalog number 16 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF161-4PB6 ENF161-6PB6 ENF161-3TB8 ENF161-3BB8 ENF161-3MB6 ENF163-4PB6 ENF163-6PB6 ENF163-3TB8 ENF163-3BB8 ENF163-3MB6 ENF164-4PB6 ENF164-6PB6 ENF164-3TB8 ENF164-3BB8 ENF164-3MB6 ENF16X-4PB6 ENF16X-6PB6 ENF16X-3TB8 ENF16X-3BB8 ENF16X-3MB6 25 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF251-4PB6 ENF251-6PB6 ENF251-3TB8 ENF251-3BB8 ENF251-3MB6 ENF253-4PB6 ENF253-6PB6 ENF253-3TB8 ENF253-3BB8 ENF253-3MB6 ENF254-4PB6 ENF254-6PB6 ENF254-3TB8 ENF254-3BB8 ENF254-3MB6 ENF25X-4PB6 ENF25X-6PB6 ENF25X-3TB8 ENF25X-3BB8 ENF25X-3MB6 40 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF321-4PB6 ENF321-6PB6 ENF321-3TB8 ENF321-3BB8 ENF321-3MB6 ENF323-4PB6 ENF323-6PB6 ENF323-3TB8 ENF323-3BB8 ENF323-3MB6 ENF324-4PB6 ENF324-6PB6 ENF324-3TB8 ENF324-3BB8 ENF324-3MB6 ENF32X-4PB6 ENF32X-6PB6 ENF32X-3TB8 ENF32X-3BB8 ENF32X-3MB6 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF451-4PB6 ENF451-6PB6 ENF451-3TB8 ENF451-3BB8 ENF451-3MB6 ENF453-4PB6 ENF453-6PB6 ENF453-3TB8 ENF453-3BB8 ENF453-3MB6 ENF454-4PB6 ENF454-6PB6 ENF454-3TB8 ENF454-3BB8 ENF454-3MB6 ENF45X-4PB6 ENF45X-6PB6 ENF45X-3TB8 ENF45X-3BB8 ENF45X-3MB6 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF631-4PB6 ENF631-6PB6 ENF631-3TB8 ENF631-3BB8 ENF631-3MB6 ENF633-4PB6 ENF633-6PB6 ENF633-3TB8 ENF633-3BB8 ENF633-3MB6 ENF634-4PB6 ENF634-6PB6 ENF634-3TB8 ENF634-3BB8 ENF634-3MB6 ENF63X-4PB6 ENF63X-6PB6 ENF63X-3TB8 ENF63X-3BB8 ENF63X-3MB6 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF301-4PB6 ENF301-6PB6 ENF301-3TB8 ENF301-3BB8 ENF301-3MB6 ENF303-4PB6 ENF303-6PB6 ENF303-3TB8 ENF303-3BB8 ENF303-3MB6 ENF304-4PB6 ENF304-6PB6 ENF304-3TB8 ENF304-3BB8 ENF304-3MB6 ENF30X-4PB6 ENF30X-6PB6 ENF30X-3TB8 ENF30X-3BB8 ENF30X-3MB6 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF601-4PB6 ENF601-6PB6 ENF601-3TB8 ENF601-3BB8 ENF601-3MB6 ENF603-4PB6 ENF603-6PB6 ENF603-3TB8 ENF603-3BB8 ENF603-3MB6 ENF604-4PB6 ENF604-6PB6 ENF604-3TB8 ENF604-3BB8 ENF604-3MB6 ENF60X-4PB6 ENF60X-6PB6 ENF60X-3TB8 ENF60X-3BB8 ENF60X-3MB6 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF1001-4PB6 ENF1001-6PB6 ENF1001-3TB8 ENF1001-3BB8 ENF1001-3MB6 ENF1003-4PB6 ENF1003-6PB6 ENF1003-3TB8 ENF1003-3BB8 ENF1003-3MB6 ENF1004-4PB6 ENF1004-6PB6 ENF1004-3TB8 ENF1004-3BB8 ENF1004-3MB6 ENF100X-4PB6 ENF100X-6PB6 ENF100X-3TB8 ENF100X-3BB8 ENF100X-3MB6 2 Pole 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF1251-2PB6 ENF1251-4PB6 ENF1251-6PB2 ENF1251-3TB8 — ENF1251-3MB6 ENF1253-2PB6 ENF1253-4PB6 ENF1253-6PB2 ENF1253-3TB8 — ENF1253-3MB6 ENF1254-2PB6 ENF1254-4PB6 ENF1254-6PB4 ENF1254-3TB8 — ENF1254-3MB8 ENF125X-2PB6 ENF125X-4PB6 ENF125X-6PB4 ENF125X-3TB8 — ENF125X-3MB8 2 Pole 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF2001-2PB8 ENF2001-4PB8 ENF2001-6PB4 ENF2001-3TB4 ENF2001-3BB4 ENF2001-3MB8 ENF2003-2PB8 ENF2003-4PB8 ENF2003-6PB4 ENF2003-3TB4 ENF2003-3BB4 ENF2003-3MB8 ENF2004-2PB8 ENF2004-4PB8 ENF2004-6PB4 ENF2004-3TB4 ENF2004-3BB4 ENF2004-3MB8 ENF200X-2PB8 ENF200X-4PB8 ENF200X-6PB4 ENF200X-3TB4 ENF200X-3BB4 ENF200X-3MB8 2 Pole 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF4001-2PB4 ENF4001-4PB4 ENF4001-6P8 ENF4001-3TB4 ENF4001-3B6 ENF4001-3MB4 ENF4003-2PB4 ENF4003-4PB4 ENF4003-6P8 ENF4003-3TB4 ENF4003-3B6 ENF4003-3MB4 ENF4004-2PB4 ENF4004-4PB4 ENF4004-6P8 ENF4004-3TB4 ENF4004-3B6 ENF4004-3MB4 ENF400X-2PB4 ENF400X-4PB4 ENF400X-6P8 ENF400X-3TB4 ENF400X-3B6 ENF400X-3MB4 60 80 30 60 100 125 200 400 Type of switch 4X Stainless Catalog number For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 119 Bussmann® Enclosed Non-Fusible Disconnect Switches 16A – 400A UL General purpose amp rating 16 25 40 60 80 30 60 100 125 200 400 Other Configurations NEMA Enclosure type 12 Catalog number 7&9 Catalog number IEC Enclosure type IP65 Catalog number Type of switch 4X Plastic Catalog number 4 pole 6 pole Transfer Bypass Mech. interlock ENF16P-4PB6 ENF16P-6PB6 ENF16P-3TB8 ENF16P-3BB8 ENF16P-3MB6 ENF162-4PB6 ENF162-6PB6 ENF162-3TB8 ENF162-3BB8 ENF162-3MB6 ENF167-4P ENF167-6P ENF167-3T ENF167-3B — ENF16E-4PBJ ENF16E-6PBJ — — — 4 pole 6 pole Transfer Bypass Mech. interlock ENF25P-4PB6 ENF25P-6PB6 ENF25P-3TB8 ENF25P-3BB8 ENF25P-3MB6 ENF252-4PB6 ENF252-6PB6 ENF252-3TB8 ENF252-3BB8 ENF252-3MB6 ENF257-4P ENF257-6P ENF257-3T ENF257-3B — ENF25E-4PBJ ENF25E-6PBJ — — — 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF32P-4PB6 ENF32P-6PB6 ENF32P-3TB8 ENF32P-3BB8 ENF32P-3MB6 ENF322-4PB6 ENF322-6PB6 ENF322-3TB8 ENF323-3BB8 ENF322-3MB6 ENF327-4P ENF327-6P ENF327-3T ENF327-3B — ENF32E-4PBJ ENF32E-6PBJ — — — 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF45P-4PB6 ENF45P-6PB6 ENF45P-3TB8 ENF45P-3BB8 ENF45P-3MB6 ENF452-4PB6 ENF452-6PB6 ENF452-3TB8 ENF452-3BB8 ENF452-3MB6 ENF457-4P ENF457-6P ENF457-3T ENF457-3B — ENF45E-4PBJ ENF45E-6PBJ — — — 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF63P-4PB6 ENF63P-6PB6 ENF63P-3TB8 ENF63P-3BB8 ENF63P-3MB6 ENF632-4PB6 ENF632-6PB6 ENF632-3TB8 ENF632-3BB8 ENF632-3MB6 ENF637-4P ENF637-6P ENF637-3T ENF637-3B — ENF63E-4PBJ ENF637-6PBJ — — — 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF30P-4PB6 ENF30P-6PB6 ENF30P-3TB8 ENF30P-3BB8 ENF30P-3MB6 ENF302-4PB6 ENF302-6PB6 ENF302-3TB8 ENF302-3BB8 ENF302-3MB6 ENF307-4P ENF307-6P ENF307-3T ENF307-3B — ENF30E-4PB4 ENF30E-6PB6 — — — 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF60P-4PB6 ENF60P-6PB6 ENF60P-3TB8 ENF60P-3BB8 ENF60P-3MB6 ENF602-4PB6 ENF602-6PB6 ENF602-3TB8 ENF602-3BB8 ENF602-3MB6 ENF607-4P ENF607-6P ENF607-3T ENF607-3B — ENF60E-4PB4 ENF60E-6PB6 — — — 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF100P-4PB6 ENF100P-6PB6 ENF100P-3TB8 ENF100P-3BB8 ENF100P-3MB6 ENF1002-4PB6 ENF1002-6PB6 ENF1002-3TB8 ENF1002-3BB8 ENF1002-3MB6 ENF1007-4P ENF1007-6P ENF1007-3T ENF1007-3B — ENF100E-4PB4 ENF100E-6PB6 — — — 2 Pole 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF125P-2PB6 ENF125P-4PB6 ENF125P-6PB2 ENF125P-3TB8 — ENF125P-3MB6 ENF1252-2PB6 ENF1252-4PB6 ENF1252-6PB2 ENF1252-3TB8 — ENF1252-3MB6 ENF1257-2P ENF1257-4P ENF1257-6P ENF1257-3T — — — — — — — — 2 Pole 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF200P-2PB8 ENF200P-4PB8 ENF200P-6PB4 ENF200P-3TB4 ENF200P-3BB4 ENF200P-3MB8 ENF2002-2PB8 ENF2002-4PB8 ENF2002-6PB4 ENF2002-3TB4 ENF2002-3BB4 ENF2002-3MB8 ENF2007-2P ENF2007-4P ENF2007-6P ENF2007-3T ENF2007-3B — — — — — — — 2 Pole 4 Pole 6 Pole Transfer Bypass Mech. interlock ENF400P-2PB4 ENF400P-4PB4 ENF400P-6P8 ENF400P-3TB4 ENF400P-3B6 ENF400P-3MB4 ENF4002-2PB4 ENF4002-4PB4 ENF4002-6P8 ENF4002-3TB4 ENF4002-3B6 ENF4002-3MB4 ENF4007-2P ENF4007-4P ENF4007-6P ENF4007-3T ENF4007-3B — — — — — — — For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006 120 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Disconnect Switches Bussmann® Fused, Dead Front, Disconnect Switches 15149 Series Voltage Ratings: 600Vac, 30A Agency Information: UL Recognized, file E116716 for General Industrial installations. Guide WFXV2. CSA certified, file LR37129-6 • In 2 and 3 poles. • Class J fuses. • Fuse holders in the pull-out head eliminate possibility of electric shock while changing fuse. • Examined under the new proposed standard UL 1429 which imparts a stricter set of test conditions than the former program that combined the applicable portions for UL 512 (Fuse Holders) and UL 98 (Enclosed Switches). Specifications Voltage Rating 600V AC (maximum) Current Rating 0 to 30A Motor Rating 5 HP Dielectric Withstand 2200V Current Withstand 200,000 RMS Symmetrical Amperes Ordering information: 15149 is available in 2 or 3 poles. To order: Basic Part No. + number of poles. Example: 15149-2 = 2-pole device. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 1141 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 121 Disconnect Switches Bussmann® Power Module™ —All-in-one Elevator Disconnect Bussmann® Power Module™ (Fusible switch with shunt trip and fire safety interface to allow for single point tie in with fire alarm system.) Complies with: NFPA 70 (NEC®; National Electrical Code®) ANSI/ASME A17.1 (Safety Code for Elevators and Escalators) NFPA 72 (National Fire Alarm Code®) Features and Accessories: • Shunt trip 120V • Accepts LPJ-(amp)SP Class J fuses • Control Power Transformer • Fire Safety Interface Relay • Key to Test Switch • Pilot Light (on) • Mechanically Interlocked Auxiliary Contact • Neutral (200% Capability) • Control Power Fuses and Blocks • For added safety, use the Bussmann SAMI fuse covers to improve maintenance personnel protection (OSHA 1910.333, paragraph C). Voltage Ratings: 600Vac, 3Ø Fused Power Switch Short-Circuit Current Rating: 200,000A RMS PS PMP Power Module™ Switch (Single Elevator Applications) Power Module™ Panel (Multiple Elevator Applications) Ampere Ratings: 30-400A Ampere Ratings: Feeder Switches - 30-400A Main Switches2 - 400-800A Agency Information: UL Listed (UL 98) Enclosed and Dead front switch Guide 96NK3917, File E182262 NEMA 1, UL 50 Listed enclosure1 ULc per Canadian Standards C22.2, No. 0-M91CAN/CSA C22.2, No. 4-M89 Enclosed switch. 1NEMA 12, 3R, and 4 enclosures also available Data Sheet: 1145 122 Agency Information: UL Listed (UL 67) Panel Boards or (UL 891) Dead Front Switchboard, File E181664 ULc per Canadian Standards Service Entrance Rated 2Contact Bussmann for applications greater than 800A Data Sheet: 1146 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses North American Style — General Information Voltage Rating 130Vac/dc 1000 to 4000A 150Vac/dc 70 to 1000A 250Vac/dc 35 to 2500A 500Vac/dc 35 to 1600A 600Vac 1 to 1000A 700Vac/dc 5 to 1200A 800Vdc 35 to 600A 1000Vac, 700Vdc 35 to 2000A All Bussmann North American Style fuses are certified for their rated voltage. Characteristics: • Low energy let-thru (I2t) • Low watts loss • Superior cycling capability • Low arc voltage • Excellent dc performance North American style fuses provide an excellent solution for medium power applications. While there are currently no published standards for these fuses, the industry has standardized on mounting centers that accept Bussmann fuses. Accessories Bussmann offers a comprehensive line of fuse bases that provide the user with design and manufacturing flexibility. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 123 Bussmann® High Speed Fuses North American Style FWA 130V Voltage Rating: 130Vac/130Vdc (130Vdc rating applies to 1000 through 2000A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics Rated Current RMS-Amps Ordering Information I2t (A2 SEC) @ 100kA Pre-arc Clearing at 130V Watts Loss Part Number Carton Qty. Carton Weight (lbs) 1000 170000 460000 60.0 FWA-1000AH 1 3.3 1200 270000 730000 70.0 FWA-1200AH 1 3.3 1500 520000 1400000 78.0 FWA-1500AH 1 3.3 2000 860000 2400000 108.0 FWA-2000AH 1 3.3 2500 1500000 4100000 130.0 FWA-2500AH 1 3.3 3000 2100000 5700000 150.0 FWA-3000AH 1 3.3 4000 3400000 9200000 257.0 FWA-4000AH 1 3.3 Data Sheet: 720001 FWA 150V Voltage Rating: 150Vac/150Vdc (150Vdc rating applies to 70 through 800A only.) Interrupting Rating: 100kA RMS Symmetrical. (70-400A) 200kA RMS Symmetrical. (450-1000A) Agency Information: UL Recognized, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics Rated Current RMS-Amps Ordering Information I2t (A2 SEC) @ 100kA Pre-arc Clearing at 150V Watts Loss Carton Qty. Carton Weight (lbs) 70 470 4000 6.9 FWA-70B 10 1.76 80 670 6000 7.7 FWA-80B 10 1.76 100 1200 12000 9.0 FWA-100B 10 1.76 125 1870 18000 11.2 FWA-125B 10 1.76 150 2700 26000 13.5 FWA-150B 10 1.76 200 4780 45000 17.6 FWA-200B 10 1.76 250 7470 70000 22.5 FWA-250B 10 1.76 300 10760 100000 27.0 FWA-300B 10 1.76 350 15700 140000 30.6 FWA-350B 10 1.76 400 20300 180000 35.2 FWA-400B 10 1.76 500 39000 120000 35.0 FWA-500A 5 2.42 600 46000 140000 47.0 FWA-600A 5 2.42 700 75000 220000 49.0 FWA-700A 5 2.42 800 92000 280000 58.0 FWA-800A 5 2.42 1000 170000 510000 60.0 FWA-1000A 5 2.42 Part Number CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 720002 124 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses North American Style FWX 250V Voltage Rating: 250Vac/250Vdc (250Vdc rating on 35 through 800A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13, 35-800A Watts loss provided at rated current. Electrical Characteristics Rated Current RMS-Amps Ordering Information I2t (A2 SEC) @ 100kA Pre-arc Clearing at 250V Watts Loss Carton Qty. Carton Weight (lbs) 35 50 230 4.2 FWX-35A 5 1.40 40 60 310 5.2 FWX-40A 5 1.40 45 80 390 5.7 FWX-45A 5 1.40 50 100 520 6.0 FWX-50A 5 1.40 60 140 740 8.1 FWX-60A 5 1.40 70 330 1400 7.2 FWX-70A 1 0.32 80 430 1850 8.1 FWX-80A 1 0.32 90 570 2450 9.0 FWX-90A 1 0.32 100 740 3150 10.0 FWX-100A 1 0.32 125 1130 4850 12.5 FWX-125A 1 0.32 150 1620 6950 15.7 FWX-150A 1 0.32 175 2170 9300 18.5 FWX-175A 1 0.32 200 2790 12000 22 FWX-200A 1 0.32 225 3210 14700 24 FWX-225A 1 0.52 250 3960 18100 27 FWX-250A 1 0.52 275 4720 21600 31 FWX-275A 1 0.52 300 6000 27300 32 FWX-300A 1 0.52 350 10600 48600 39 FWX-350A 1 0.52 400 14500 66100 44 FWX-400A 1 0.52 450 22100 101000 49 FWX-450A 1 0.52 500 28000 128000 54 FWX-500A 1 0.52 600 41100 188000 62 FWX-600A 1 0.52 700 48800 190000 72 FWX-700A 1 0.90 800 59000 230000 84 FWX-800A 1 0.90 1000 44000 360000 100 FWX-1000AH 1 2.86 1200 92000 750000 103 FWX-1200AH 1 2.86 1500 120000 880000 140 FWX-1500AH 1 2.86 1600 160000 1200000 140 FWX-1600AH 1 2.86 2000 320000 2300000 151 FWX-2000AH 1 2.86 2500 670000 4700000 163 FWX-2500AH 1 2.86 Part Number CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 720005 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 125 Bussmann® High Speed Fuses North American Style FWH 500V Voltage Rating: 500Vac/500Vdc (500Vdc rating applies to 35 through 800A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13, 35-1200A; CSA Component Acceptance 35-1600A Watts loss provided at rated current. Electrical Characteristics Rated Current RMS-Amps Ordering Information I2t (A2 SEC) @ 100kA Pre-arc Clearing at 500V Watts Loss Carton Qty. Carton Weight (lbs) 35 34 150 .8 FWH- 35B 10 1.34 40 76 320 7.5 FWH-40B 10 1.34 45 105 450 7.5 FWH-45B 10 1.34 50 135 670 7.5 FWH-50B 10 1.34 60 210 900 9.9 FWH-60B 10 1.34 70 210 900 10.6 FWH-70B 10 2.05 80 305 1400 12.7 FWH-80B 10 2.05 90 360 1600 15 FWH-90B 10 2.05 100 475 2000 17 FWH-100B 10 2.05 125 800 3500 25 FWH-125B 5 1.65 150 1100 4600 30 FWH-150B 5 1.65 175 1450 6200 35 FWH-175B 5 1.65 200 1900 8500 40 FWH-200B 5 1.65 225 4600 23300 39 FWH-225A 1 0.57 250 6300 32200 41 FWH-250A 1 0.57 275 7900 40300 46 FWH-275A 1 0.57 300 9800 49800 51 FWH-300A 1 0.57 325 13700 63800 53 FWH-325A 1 0.57 350 14500 72900 58 FWH-350A 1 0.57 400 19200 96700 65 FWH-400A 1 0.57 450 24700 127000 74 FWH-450A 1 1.00 500 29200 149000 84 FWH-500A 1 1.00 600 41300 206000 108 FWH-600A 1 1.00 700 55000 298000 120 FWH-700A 1 2.14 800 76200 409000 129 FWH-800A 1 2.14 1000 92000 450000 145 FWH-1000A 1 4.62 1200 122000 600000 180 FWH-1200A 1 4.62 1400 200000 1000000 210 FWH-1400A 1 11.66 1600 290000 1400000 230 FWH-1600A 1 11.66 Part Number CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 720007 126 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses North American Style KAC 600V KBC 600V Voltage Rating: 600Vac Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13,1-600A Voltage Rating: 600Vac Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13, • For new installations, Bussmann recommends the 700V FWP series fuse. The 600V fuses are supplied as replacements only. 35-600A • For new installations, Bussmann recommends the 700 Volt FWP series fuse. The 600V fuses are supplied as replacements only. Ordering Information Part Number KAC-1 KAC-2 KAC-3 KAC-4 KAC-5 KAC-6 KAC-7 KAC-8 KAC-9 KAC-10 KAC-12 KAC-15 KAC-17.5 KAC-20 KAC-25 KAC-30 KAC-35 KAC-40 KAC-45 KAC-50 KAC-60 KAC-70 KAC-80 KAC-90 KAC-100 KAC-110 KAC-125 KAC-150 KAC-175 KAC-200 KAC-225 KAC-250 KAC-300 KAC-350 KAC-400 KAC-450 KAC-500 KAC-600 KAC-700 KAC-800 KAC-1000 Carton Qty. 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 5 5 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Carton Weight (lbs) 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 1.40 1.40 1.40 1.40 1.40 1.56 1.56 1.56 1.56 0.78 0.78 0.78 0.78 0.78 1.92 1.92 1.92 1.92 1.92 3.16 3.16 3.16 3.16 3.16 6.24 Ordering Information Part Number KBC-35 KBC-40 KBC-45 KBC-50 KBC-60 KBC-70 KBC-80 KBC-90 KBC-100 KBC-110 KBC-125 KBC-150 KBC-175 KBC-200 KBC-225 KBC-250 KBC-300 KBC-350 KBC-400 KBC-450 KBC-500 KBC-600 KBC-800 Carton Qty. 10 10 10 10 10 5 5 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Carton Weight (lbs) 1.40 1.40 1.40 1.40 1.40 1.44 1.44 1.44 1.44 0.48 0.48 0.48 0.48 0.48 0.77 0.77 0.77 0.77 0.77 1.32 1.32 1.32 4.50 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 720009 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 720010 127 Bussmann® High Speed Fuses North American Style FWP 700V Voltage Rating: 700Vac/700Vdc (700Vdc rating applies to 5 through 800A only.) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13; CSA Component Acceptance Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Rated Current RMS-Amps Ordering Information I2t (A2 SEC) @ 100kA Pre-arc Clearing at 700V Watts Loss Carton Qty. Carton Weight (lbs) 5 1.6 10 1.5 FWP-5B 10 2.25 10 3.6 20 4 FWP-10B 10 2.25 15 10 75 5.5 FWP-15B 10 2.25 20 26 180 6 FWP-20B 10 2.25 25 44 340 7 FWP-25B 10 2.25 30 58 450 9 FWP-30B 10 2.25 35 34 160 12 FWP-35B 10 2.42 40 76 320 12 FWP-40B 10 2.42 50 135 600 12 FWP-50B 10 2.42 60 210 950 15.5 FWP-60B 10 2.42 70 305 1400 18 FWP-70B 10 2.42 80 360 1600 21 FWP-80B 10 2.42 90 415 1900 25 FWP-90B 10 2.42 100 540 2500 27 FWP-100B 10 2.42 125 1800 7300 28 FWP-125A 1 0.65 150 2900 11700 32 FWP-150A 1 0.65 175 4200 16700 35 FWP-175A 1 0.65 200 5500 22000 43 FWP-200A 1 0.65 225 7700 31300 45 FWP-225A 1 1.17 250 10500 42500 48 FWP-250A 1 1.17 300 17600 71200 58 FWP-300A 1 1.17 350 23700 95600 65 FWP-350A 1 1.17 400 31000 125000 78 FWP-400A 1 1.17 450 36400 137000 94 FWP-450A 1 2.39 500 45200 170000 107 FWP-500A 1 2.39 600 66700 250000 122 FWP-600A 1 2.39 700 54000 300000 125 FWP-700A 1 1.21 800 78000 450000 140 FWP-800A 1 1.21 900 91500 530000 150 FWP-900A 1 6.60 1000 120000 600000 170 FWP-1000A 1 6.60 1200 195000 1100000 190 FWP-1200A 1 6.60 Part Number Data Sheet: 720012 128 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses North American Style FWJ 1000V Voltage Rating: 1000Vac/800Vdc (Ampere ratings 35-200 and 500-600 rated up to 800Vdc) Interrupting Rating: 25kA for 35-200A, 100kA for 250-600A Agency Information: UL Recognition on 35 through 600A only, Std. 248-13 Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Rated Current RMS-Amps Ordering Information I2t (A2 SEC) @ 100kA Pre-arc Clearing at 1000V Watts Loss Carton Qty. Carton Weight (lbs) 35 210 2000 7 FWJ-35A 10 4.18 40 300 2500 8 FWJ-40A 10 4.18 50 470 3500 10 FWJ-50A 10 4.18 60 670 5000 11 FWJ-60A 10 4.18 70 1100 6900 12 FWJ-70A 10 4.18 80 1550 9700 13 FWJ-80A 10 4.18 90 1900 12000 14 FWJ-90A 10 4.18 100 2800 17500 15 FWJ-100A 10 4.18 125 4800 35000 16 FWJ-125A 1 4.40 150 6300 45000 25 FWJ-150A 1 4.40 175 7500 65000 30 FWJ-175A 1 4.40 200 11700 80000 32 FWJ-200A 1 4.40 250 9000 50000 50 FWJ-250A 1 4.84 300 15000 80000 56 FWJ-300A 1 4.84 350 22000 120000 62 FWJ-350A 1 4.84 400 32000 180000 67 FWJ-400A 1 4.84 500 28500 155000 95 FWJ-500A 1 4.84 600 46500 260000 105 FWJ-600A 1 4.84 800 87000 500000 182 FWJ-800A 1 5.28 1000 190000 1100000 206 FWJ-1000A 1 5.28 1200 370000 2100000 240 FWJ-1200A 1 5.28 1400 470000 2700000 248 FWJ-1400A 1 5.28 1600 700000 4000000 267 FWJ-1600A 1 5.28 1800 925000 5300000 239 FWJ-1800A 1 5.28 2000 1330000 7600000 244 FWJ-2000A 1 5.28 Part Number Data Sheet: 720027 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 129 Bussmann® High Speed Fuses North American Style Fuseblocks Modular Style Bussmann offers a comprehensive line of fuse bases that provide the user with design and manufacturing flexibility. Two identical half bases make up a Buss Modular fuse base. These “split” units can be panel mounted any distance apart to accommodate any length fuse. Stud Type The simpler design is the C5268 Series Modular fuse base. With this design, the fuse terminal and cable (with termination) are mounted on the same stud, minimizing labor needed for installation. The stud Type Base is available in the configuration shown in the table below. (Must order 2 pieces per fuse, they do not come in pairs.) Part No. Stud Heights Stud Dia. & Threads C5268-1 1.00∑ fiΩ¡§-18 C5268-2 1.75∑ fiΩ¡§-18 C5268-3 0.75∑ fiΩ¡§-18 C5268-4 1.00∑ ⁄Ω¢-20 C5268-5 1.75∑ ⁄Ω¢-20 Connector Type Bussmann also offers a modular style fuse base that utilizes a tin plated connector (for wire termination and heat dissipation) and a plated steel stud (for fuse mounting). The connector type fuse base is available in the configurations shown below. Consult Bussmann for additional product details. (Order 1 piece per fuse, parts come in pairs.) Modular Base Style Max. Voltage Max. Fuse Current Rating BH-0 Series 700V 100A BH-1 Series 2500V 400A BH-2 Series 5000V 400A BH-3 Series 1250V 700A See page 67. Fixed Center Base Style Bussmann offers a comprehensive line of fixed mount style fuse bases under the trademark TRON Rectifier Fuseblocks. The cable and fuse connections are similar to the Stud Type fuse base — both are mounted on the same stud. Consult Bussmann for complete product details. ® CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 720033 130 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body — General Information Voltage Rating 690Vac 1250Vac 10 to 7500A 50 to 1400A All Bussmann European Style fuses are tested to IEC 60269, Part 4. This standard requires a test voltage which is 10% higher than the rated voltage. In North America, fuses are required to clear only their rated voltage. Characteristics Designed and tested to: • IEC 60269: Part 4 • UL Recognized • Minimal energy let-thru (I2t) • Low operating temperature • Low Watts loss General Information Each European Style fuse is available with a number of different end fittings. Options include: • DIN 43 653 • North American Slotted Blade • DIN 43 620 • Flush End (Metric/U.S.) • French Style Accessories European Style fuses are available with three different open fuse indicator systems. Options include visual indication and indication utilizing a microswitch. Fuseblocks are also available for most applications. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 131 Bussmann® High Speed Fuses European Style Square Body DIN 43 653 —10-400A Voltage Rating: 690V (IEC) & 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 CSA Component Acceptance on Size 000 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Ordering Information Watts Loss -U/80 Without Indicator -/80 Visual Indicator -TN/80 Type T Indicator for Micro Carton Qty. Carton Weight (Kg) I2t (A2s) Size 000 00 Rated Current RMS-Amps Pre-arc Clearing at 660V 10 3.8 25.5 3.0 170M1308* 170M1358* 170M1408* 10 1.34 16 7.2 48 5.5 170M1309* 170M1359* 170M1409* 10 1.34 20 11.5 78 7 170M1310* 170M1360* 170M1410* 10 1.34 25 19 130 9 170M1311* 170M1361* 170M1411* 10 1.34 32 40 270 10 170M1312* 170M1362* 170M1412* 10 1.34 40 69 460 12 170M1313* 170M1363* 170M1413* 10 1.34 50 115 770 15 170M1314* 170M1364* 170M1414* 10 1.34 63 215 1450 16 170M1315* 170M1365* 170M1415* 10 1.34 80 380 2550 19 170M1316* 170M1366* 170M1416* 10 1.34 100 695 4650 24 170M1317* 170M1367* 170M1417* 10 1.34 125 1200 8500 28 170M1318* 170M1368* 170M1418* 10 1.34 160 2300 16000 32 170M1319* 170M1369* 170M1419* 10 1.34 200 4200 28000 37 170M1320* 170M1370* 170M1420* 10 1.34 250 7750 51500 42 170M1321* 170M1371* 170M1421* 10 1.34 315 12000 80500 52 170M1322* 170M1372* 170M1422* 10 1.34 25 19 130 6 — 170M2608 170M2658 5 1.05 32 28.5 195 7 — 170M2609 170M2659 5 1.05 40 50 360 9 — 170M2610 170M2660 5 1.05 50 95 640 10 — 170M2611 170M2661 5 1.05 63 170 1200 12 — 170M2612 170M2662 5 1.05 80 310 2100 15 — 170M2613 170M2663 5 1.05 100 620 4150 20 — 170M2614 170M2664 5 1.05 125 1000 6950 25 — 170M2615 170M2665 5 1.05 160 1900 13000 30 — 170M2616 170M2666 5 1.05 200 3400 23000 35 — 170M2617 170M2667 5 1.05 250 6250 42000 45 — 170M2618 170M2668 5 1.05 315 10000 68500 55 — 170M2619 170M2669 5 1.05 350 13500 91500 60 — 170M2620 170M2670 5 1.05 400 18000 125000 70 — 170M2621 170M2671 5 1.05 *UL Recognized / CSA Component Accepted on size 000. Data Sheet: 720013 132 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body DIN 43 653 — 40-2000A Voltage Rating: 690V (IEC) & 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information Watts Loss -/80 Visual Indicator -TN/80 Type T Indicator for Micro -/110 Visual Indicator -TN/110 Type T Indicator for Micro Carton Qty. Carton Weight (Kg) 9 11 14 18 21 26 30 170M3008* 170M3009* 170M3010* 170M3011* 170M3012* 170M3013* 170M3014* 170M3058* 170M3059* 170M3060* 170M3061* 170M3062* 170M3063* 170M3064* 170M3158* 170M3159* 170M3160* 170M3161* 170M3162* 170M3163* 170M3164* 170M3208* 170M3209* 170M3210* 170M3211* 170M3212* 170M3213* 170M3214* 5 5 5 5 5 5 5 1.50 1.50 1.50 1.50 1.50 1.50 1.50 35 40 50 55 60 65 70 75 80 45 55 58 60 65 70 72 75 80 85 95 100 65 70 75 80 90 95 105 110 115 120 130 95 100 105 110 115 120 125 130 140 155 160 160 165 175 170M3015* 170M3016* 170M3017* 170M3018* 170M3019* 170M3020* 170M3021* 170M3022* 170M3023* 170M4008* 170M4009* 170M4010* 170M4011* 170M4012* 170M4013* 170M4014* 170M4015* 170M4016* 170M4017* 170M4018* 170M4019 170M5008* 170M5009* 170M5010* 170M5011* 170M5012* 170M5013* 170M5014* 170M5015* 170M5016* 170M5017* 170M5018* 170M6008* 170M6009* 170M6010* 170M6011* 170M6012* 170M6013* 170M6014* 170M6015* 170M6016* 170M6017* 170M6018* 170M6019* 170M6020 170M6021 170M3065* 170M3066* 170M3067* 170M3068* 170M3069* 170M3070* 170M3071* 170M3072* 170M3073* 170M4058* 170M4059* 170M4060* 170M4061* 170M4062* 170M4063* 170M4064* 170M4065* 170M4066* 170M4067* 170M4068* 170M4069 170M5058* 170M5059* 170M5060* 170M5061* 170M5062* 170M5063* 170M5064* 170M5065* 170M5066* 170M5067* 170M5068* 170M6058* 170M6059* 170M6060* 170M6061* 170M6062* 170M6063* 170M6064* 170M6065* 170M6066* 170M6067* 170M6068* 170M6069* 170M6070 170M6071 170M3165* 170M3166* 170M3167* 170M3168* 170M3169* 170M3170* 170M3171* 170M3172* 170M3173* 170M4158* 170M4159* 170M4160* 170M4161* 170M4162* 170M4163* 170M4164* 170M4165* 170M4166* 170M4167* 170M4168* 170M4169 170M5158* 170M5159* 170M5160* 170M5161* 170M5162* 170M5163* 170M5164* 170M5165* 170M5166* 170M5167* 170M5168* 170M6158* 170M6159* 170M6160* 170M6161* 170M6162* 170M6163* 170M6164* 170M6165* 170M6166* 170M6167* 170M6168* 170M6169 170M6170 170M6171 170M3215* 170M3216* 170M3217* 170M3218* 170M3219* 170M3220* 170M3221* 170M3222* 170M3223* 170M4208* 170M4209* 170M4210* 170M4211* 170M4212* 170M4213* 170M4214* 170M4215* 170M4216* 170M4217* 170M4218* 170M4219 170M5208* 170M5209* 170M5210* 170M5211* 170M5212* 170M5213* 170M5214* 170M5215* 170M5216* 170M5217* 170M5218* 170M6208* 170M6209* 170M6210* 170M6211* 170M6212* 170M6213* 170M6214* 170M6215* 170M6216* 170M6217* 170M6218* 170M6219 170M6220 170M6221 5 5 5 5 5 5 5 5 5 3 (-/80) — 2 (-/110) — — — — — — — 2 2 2 2 2 2 2 2 2 2 2 2 (-/80) — 1 (-/110) — — — — — — — — — 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.29 — — 0.94 — — — — — — — — 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.66 — — 0.89 — — — — — — — — — — I2t (A2s) Size Rated Current RMS-Amps 40 50 63 80 100 125 160 1* 1 2 3 *UL Pre-arc Clearing at 660V 40 77 115 185 360 550 1100 270 515 770 1250 2450 3700 7500 200 2200 250 4200 315 7000 350 10000 400 15000 450 21000 500 27000 550 34000 630 48500 200 1650 250 3100 315 6200 350 8500 400 13500 450 17000 500 25000 550 34000 630 52000 700 69500 800 105000 ‡900 155000 400 11000 450 15500 500 21500 550 28000 630 41000 700 60500 800 86000 900 125000 1000 180000 1100 245000 1250 365000 500 14000 550 19500 630 31000 700 44500 800 69500 900 100000 1000 140000 1100 190000 1250 290000 1400 370000 1500 460000 1600 580000 †1800 880000 ‡2000 1150000 Recognized / CSA Component Accepted. 15000 28500 46500 68500 105000 140000 180000 230000 325000 11500 21000 42000 59000 91500 120000 170000 230000 350000 465000 725000 ‡850000 74000 105000 145000 190000 275000 405000 575000 840000 1250000 1600000 2400000 95000 135000 210000 300000 465000 670000 945000 1300000 1950000 2450000 3100000 3900000 †5250000 ‡6350000 Rated voltage †600V ‡550V Data Sheet: 720014 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 133 Bussmann® High Speed Fuses European Style Square Body DIN 43 653 — 40-2000A Voltage Rating: 690V (IEC) & 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information Watts Loss -KN/80 Type K Indicator for Micro -KN/110 Type K Indicator for Micro Carton Qty. Carton Weight (Kg) 9 11 14 18 21 26 170M3108* 170M3109* 170M3110* 170M3111* 170M3112* 170M3113* 170M3258* 170M3259* 170M3260* 170M3261* 170M3262* 170M3263* 5 5 5 5 5 5 1.60 1.60 1.60 1.60 1.60 1.60 30 35 40 50 55 60 65 70 75 80 45 55 58 60 65 70 72 75 80 85 95 100 65 70 75 80 90 95 105 110 115 120 130 95 100 105 110 115 120 125 130 140 155 160 160 165 175 ‡550V 170M3114* 170M3115* 170M3116* 170M3117* 170M3118* 170M3119* 170M3120* 170M3121* 170M3122* 170M3123* 170M4108* 170M4109* 170M4110* 170M4111* 170M4112* 170M4113* 170M4114* 170M4115* 170M4116* 170M4117* 170M4118* 170M4119 170M5108* 170M5109* 170M5110* 170M5111* 170M5112* 170M5113* 170M5114* 170M5115* 170M5116* 170M5117* 170M5118* 170M6108* 170M6109* 170M6110* 170M6111* 170M6112* 170M6113* 170M6114* 170M6115* 170M6116* 170M6117* 170M6118* 170M6119* 170M6120 170M6121 170M3264* 170M3265* 170M3266* 170M3267* 170M3268* 170M3269* 170M3270* 170M3271* 170M3272* 170M3273* 170M4258* 170M4259* 170M4260* 170M4261* 170M4262* 170M4263* 170M4264* 170M4265* 170M4266* 170M4267* 170M4268* 170M4269 170M5258* 170M5259* 170M5260* 170M5261* 170M5262* 170M5263* 170M5264* 170M5265* 170M5266* 170M5267* 170M5268* 170M6258* 170M6259* 170M6260* 170M6261* 170M6262* 170M6263* 170M6264* 170M6265* 170M6266* 170M6267* 170M6268* 170M6269* 170M6270 170M6271 5 5 5 5 5 5 5 5 5 5 3 (-/80) — 2 (-/110) — — — — — — — 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.60 1.60 1.60 1.60 1.60 1.60 1.60 1.60 1.60 1.60 1.38 — — 1.00 — — — — — — — — 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 I2t (A2s) Size Rated Current RMS-Amps 40 50 63 80 100 125 1* 1 2 3 *UL 160 200 250 315 350 400 450 500 550 630 200 250 315 350 400 450 500 550 630 700 800 ‡900 400 450 500 550 630 700 800 900 1000 1100 1250 500 550 630 700 800 900 1000 1100 1250 1400 1500 1600 †1800 ‡2000 Recognized / CSA Component Pre-arc Clearing at 660V 40 77 115 185 360 550 270 515 770 1250 2450 3700 1100 2200 4200 7000 10000 15000 21000 27000 34000 48500 1650 3100 6200 8500 13500 17000 25000 34000 52000 69500 105000 155000 11000 15500 21500 28000 41000 60500 86000 125000 180000 245000 365000 14000 19500 31000 44500 69500 100000 140000 190000 290000 370000 460000 580000 880000 1150000 Accepted. 7500 15000 28500 46500 68500 105000 140000 180000 230000 325000 11500 21000 42000 59000 91500 120000 170000 230000 350000 465000 725000 ‡850000 74000 105000 145000 190000 275000 405000 575000 840000 1250000 1600000 2400000 95000 135000 210000 300000 465000 670000 945000 1300000 1950000 2450000 3100000 3900000 †5250000 ‡6350000 Rated voltage †600V Data Sheet: 720015 134 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body DIN 43 653 — 50-1400A Voltage Rating: 1250V (IEC)/1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information -/110 Visual Indicator -TN/110 Type T Indicator for Micro Carton Qty. Carton Weight (Kg) 15 20 25 30 35 170M3138* 170M3139* 170M3140* 170M3141* 170M3142* 170M3188* 170M3189* 170M3190* 170M3191* 170M3192* 5 5 5 5 5 1.90 1.90 1.90 1.90 1.90 40 45 55 60 65 70 45 50 60 65 70 75 80 85 95 100 65 70 75 80 85 90 95 100 110 115 120 125 135 85 90 95 100 105 110 115 120 125 130 135 140 145 150 170M3143* 170M3144* 170M3145* 170M3146* 170M3147* 170M3148* 170M4138* 170M4139* 170M4140* 170M4141* 170M4142* 170M4143* 170M4144* 170M4145* 170M4146* 170M4147 170M5138* 170M5139* 170M5140* 170M5141* 170M5142* 170M5143* 170M5144* 170M5145* 170M5146* 170M5147* 170M5148* 170M5149 170M5150 170M6138* 170M6139* 170M6140* 170M6141* 170M6142* 170M6143* 170M6144* 170M6145* 170M6146 170M6147 170M6148 170M6149 170M6150 170M6151 170M3193* 170M3194* 170M3195* 170M3196* 170M3197* 170M3198* 170M4188* 170M4189* 170M4190* 170M4191* 170M4192* 170M4193* 170M4194* 170M4195* 170M4196* 170M4197 170M5188* 170M5189* 170M5190* 170M5191* 170M5192* 170M5193* 170M5194* 170M5195* 170M5196* 170M5197* 170M5198* 170M5199 170M5200 170M6188* 170M6189* 170M6190* 170M6191* 170M6192* 170M6193* 170M6194* 170M6195* 170M6196* 170M6197* 170M6198* 170M6199* 170M6200 170M6201 5 5 5 5 5 5 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.90 1.90 1.90 1.90 1.90 1.90 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.18 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 1.23 I2t (A2s) Size Rated Current RMS-Amps 50 63 80 100 125 1* Pre-arc Clearing at 1000V Clearing at 1250V 135 215 420 750 1450 815 1300 2500 4450 9000 1100 1750 3350 5950 11500 160 2600 16000 200 5150 31000 250 9200 54500 315 18500 115000 350 27000 165000 400 53000 265000 160 1900 11500 200 3800 22500 250 7750 46000 315 15000 90000 1 350 20000 125000 400 29500 175000 450 42000 250000 500 69500 340000 550 95000 465000 †630 130000 660000 250 6500 38500 280 9350 55500 315 13000 77500 350 16500 97500 400 23000 140000 2 450 34000 205000 500 48000 285000 550 62000 370000 630 115000 575000 700 160000 795000 800 245000 1200000 †900 360000 1750000 †1000 480000 2350000 315 9500 58000 350 13500 81500 400 19500 120000 450 31000 185000 500 39000 235000 550 55000 325000 630 83500 495000 3 700 115000 705000 ‡800 205000 995000 ‡900 305000 1500000 ‡1000 450000 2150000 ‡1100 575000 2800000 †1250 810000 †3950000 †1400 1250000 †6000000 *UL Recognized / CSA Component Accepted. Rated voltage Watts Loss 21000 41000 73000 150000 220000 335000 15500 30000 61500 120000 165000 235000 335000 435000 590000 — 51500 74500 105000 135000 180000 270000 380000 495000 730000 1050000 1550000 — — 77500 110000 160000 245000 310000 435000 665000 940000 1300000 1900000 2750000 3600000 — — †1100V ‡1250V Data Sheet: 720029 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 135 Bussmann® High Speed Fuses European Style Square Body DIN 43 653 — 50-1400A Voltage Rating: 1250V (IEC)/1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information I2t (A2s) Size 1* 1 2 3 Rated Current RMS-Amps Pre-arc Clearing at 1000V Clearing at 1250V 50 63 80 100 125 160 135 215 420 750 1450 2600 815 1300 2500 4450 9000 16000 1100 1750 3350 5950 11500 21000 200 250 315 350 400 160 200 250 315 350 400 450 500 550 †630 250 280 315 350 400 450 500 550 630 700 800 †900 †1000 315 350 400 450 500 550 630 700 5150 9200 18500 27000 53000 1900 3800 7750 15000 20000 29500 42000 69500 95000 130000 6500 9350 13000 16500 23000 34000 48000 62000 115000 160000 245000 360000 480000 9500 13500 19500 31000 39000 55000 83500 115000 31000 54500 115000 165000 265000 11500 22500 46000 90000 125000 175000 250000 340000 465000 660000 38500 55500 77500 97500 140000 205000 285000 370000 575000 795000 1200000 1750000 2350000 58000 81500 120000 185000 235000 325000 495000 705000 ‡800 ‡900 ‡1000 ‡1100 205000 995000 305000 1500000 450000 2150000 575000 2800000 †1250 810000 †3950000 †1400 1250000 †6000000 *UL Recognized / CSA Component Accepted. Rated voltage Watts Loss -KN/110 Type K Indicator for Micro Carton Qty. Carton Weight (Kg) 15 20 25 30 35 40 170M3238* 170M3239* 170M3240* 170M3241* 170M3242* 170M3243* 2 2 2 2 2 2 0.84 0.84 0.84 0.84 0.84 0.84 41000 73000 150000 220000 335000 15500 30000 61500 120000 165000 235000 335000 435000 590000 — 51500 74500 105000 135000 180000 270000 380000 495000 730000 1050000 1550000 — — 77500 110000 160000 245000 310000 435000 665000 940000 45 55 60 65 70 45 50 60 65 70 75 80 85 95 100 65 70 75 80 85 90 95 100 110 115 120 125 135 85 90 95 100 105 110 115 120 1300000 1900000 2750000 3600000 — — †1100V 125 130 135 140 145 150 170M3244* 170M3245* 170M3246* 170M3247* 170M3248* 170M4238* 170M4239* 170M4240* 170M4241* 170M4242* 170M4243* 170M4244* 170M4245* 170M4246* 170M4247 170M5238* 170M5239* 170M5240* 170M5241* 170M5242* 170M5243* 170M5244* 170M5245* 170M5246* 170M5247* 170M5248* 170M5249 170M5250 170M6238* 170M6239* 170M6240* 170M6241* 170M6242* 170M6243* 170M6244* 170M6245* 170M6246 170M6247 170M6248 170M6249 170M6250 170M6251 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.84 0.84 0.84 0.84 0.84 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.26 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.66 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 ‡1250V Data Sheet: 720030 136 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body DIN 43 620 —10-315A Voltage Rating: 690V (IEC/UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 Rated Current: The rated current of this fuse range has been given with copper conductors that have a current density of 1.3 A/mm2 (IEC 60269-4). For conductor cross section according to IEC 60269-1, the fuses with a rated current higher than 125A must be derated. Please contact Bussmann for application assistance. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information I2t (A2s) Size 000 Rated Current RMS-Amps Pre-arc Clearing at 660V Watts Loss DIN 000 Type T Indicator for Micro Carton Qty. Carton Weight (Kg) 10 3.8 16 7.2 25.5 3.0 170M1558* 10 1.30 48 5.5 170M1559* 10 20 1.30 11.5 78 7 170M1560* 10 1.30 25 19 130 9 170M1561* 10 1.30 32 40 270 10 170M1562* 10 1.30 40 69 460 12 170M1563* 10 1.30 50 115 770 15 170M1564* 10 1.30 63 215 1450 16 170M1565* 10 1.30 80 380 2550 19 170M1566* 10 1.30 100 695 4650 24 170M1567* 10 1.30 125 1200 8500 28 170M1568* 10 1.30 160 2300 16000 32 170M1569* 10 1.30 200 4200 28000 37 170M1570* 10 1.30 250 7750 51500 42 170M1571* 10 1.30 315 12000 80500 52 170M1572* 10 1.30 *UL Recognized Data Sheet: 720016 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 137 Bussmann® High Speed Fuses European Style Square Body DIN 43 620 — 40-1000A Voltage Rating: 690V (IEC)/700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 Rated Current: The rated current of this fuse range has been given with copper conductors that have a current density of 1.3 A/mm2 (IEC 60269-4). For conductor cross section according to IEC 60269-1, the fuses with a rated current higher than 125A must be derated. Please contact Bussmann for application assistance. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information I2t (A2s) Size Rated Current RMS-Amps 1* 2 3 Pre-arc Clearing at 660V 40 40 270 50 77 515 63 115 770 80 185 100 Watts Loss DIN Type T Indicator for Micro Carton Qty. Carton Weight (Kg) 9 170M3808* 5 1.85 11 170M3809* 5 1.85 14 170M3810* 5 1.85 1250 18 170M3811* 5 1.85 360 2450 21 170M3812* 5 1.85 125 550 3700 26 170M3813* 5 1.85 160 1100 7500 30 170M3814* 5 1.85 200 2200 15000 35 170M3815* 5 1.85 250 4200 28500 40 170M3816* 5 1.85 315 7000 46500 50 170M3817* 5 1.85 350 10000 68500 55 170M3818* 5 1.85 400 15000 105000 60 170M3819* 5 1.85 400 11000 74000 65 170M5808* 5 3.00 450 15500 105000 70 170M5809* 5 3.00 500 21500 145000 75 170M5810* 5 3.00 550 28000 190000 80 170M5811* 5 3.00 630 41000 275000 90 170M5812* 5 3.00 700 60500 405000 95 170M5813* 5 3.00 500 14000 95000 95 170M6808* 1 1.15 550 19500 135000 100 170M6809* 1 1.15 630 31000 210000 105 170M6810* 1 1.15 700 44500 300000 110 170M6811* 1 1.15 800 69500 465000 115 170M6812* 1 1.15 900 100000 670000 120 170M6813* 1 1.15 1000 140000 945000 125 170M6814* 1 1.15 *UL Recognized Data Sheet: 720017 138 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body Flush End Contact 25-400A Voltage Rating: 690V (IEC) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Ordering Information Watts Loss 00B/60 Visual Indicator 00BTN/60 Type T Indicator for Microswitch Carton Qty. Carton Weight (Kg) I t (A s) 2 Size 00 Rated Current RMS-Amps 2 Pre-arc Clearing at 660V 25 19 130 6 170M2708 170M2758 5 1.35 32 28.5 195 7 170M2709 170M2759 5 1.35 40 50 360 9 170M2710 170M2760 5 1.35 50 95 640 10 170M2711 170M2761 5 1.35 63 170 1200 12 170M2712 170M2762 5 1.35 80 310 2100 15 170M2713 170M2763 5 1.35 100 620 4150 20 170M2714 170M2764 5 1.35 125 1000 6950 25 170M2715 170M2765 5 1.35 160 1900 13000 30 170M2716 170M2766 5 1.35 200 3400 23000 35 170M2717 170M2767 5 1.35 250 6250 42000 45 170M2718 170M2768 5 1.35 315 10000 68500 55 170M2719 170M2769 5 1.35 350 13500 91500 60 170M2720 170M2770 5 1.35 400 18000 125000 70 170M2721 170M2771 5 1.35 Data Sheet:720018 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 139 Bussmann® High Speed Fuses European Style Square Body Flush End Contact 40-2000A Voltage Rating: 690V (IEC) 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information Watts Loss -B/Visual Indicator -BKN/Type K Indicator for Micro -G/Visual Indicator -GKN/Type K Indicator for Micro Carton Qty. Carton Weight (Kg) I t (A s) 2 Size 1* 1 2 Rated Current RMS-Amps 2 Pre-arc Clearing at 660V 40 50 63 80 100 125 160 40 77 115 185 360 550 1100 270 515 770 1250 2450 3700 7500 9 11 14 18 21 26 30 170M3408* 170M3409* 170M3410* 170M3411* 170M3412* 170M3413* 170M3414* 170M3458* 170M3459* 170M3460* 170M3461* 170M3462* 170M3463* 170M3464* 170M3508* 170M3509* 170M3510* 170M3511* 170M3512* 170M3513* 170M3514* 170M3558* 170M3559* 170M3560* 170M3561* 170M3562* 170M3563* 170M3564* 10 (-B/-) — 10 (-G/-) — 6 2.40 — — 2.40 — — 1.62 200 250 315 350 400 450 500 550 630 2200 4200 7000 10000 15000 21000 27000 34000 48500 15000 28500 46500 68500 105000 140000 180000 230000 325000 35 40 50 55 60 65 70 75 80 170M3415* 170M3416* 170M3417* 170M3418* 170M3419* 170M3420* 170M3421* 170M3422* 170M3423* 170M3465* 170M3466* 170M3467* 170M3468* 170M3469* 170M3470* 170M3471* 170M3472* 170M3473* 170M3515* 170M3516* 170M3517* 170M3518* 170M3519* 170M3520* 170M3521* 170M3522* 170M3523* 170M3565* 170M3566* 170M3567* 170M3568* 170M3569* 170M3570* 170M3571* 170M3572* 170M3573* (-BKN/-) — — 6 (-GKN/-) — — — — — — — 1.62 — — — — — 200 250 315 350 400 450 500 550 630 700 800 ‡900 1650 3100 6200 8500 13500 17000 25000 34000 52000 69500 105000 155000 11500 21000 42000 59000 91500 120000 170000 230000 350000 465000 725000 ‡850000 45 55 58 60 65 70 72 75 80 85 95 100 170M4408* 170M4409* 170M4410* 170M4411* 170M4412* 170M4413* 170M4414* 170M4415* 170M4416* 170M4417* 170M4418* 170M4419 170M4458* 170M4459* 170M4460* 170M4461* 170M4462* 170M4463* 170M4464* 170M4465* 170M4466* 170M4467* 170M4468* 170M4469 170M4508* 170M4509* 170M4510* 170M4511* 170M4512* 170M4513* 170M4514* 170M4515* 170M4516* 170M4517* 170M4518* 170M4519 170M4558* 170M4559* 170M4560* 170M4561* 170M4562* 170M4563* 170M4564* 170M4565* 170M4566* 170M4567* 170M4568* 170M4569 6 6 6 6 6 6 6 6 6 6 6 6 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40 400 450 500 550 630 700 800 900 1000 1100 1250 11000 15500 21500 28000 41000 60500 86000 125000 180000 245000 365000 74000 105000 145000 190000 275000 405000 575000 840000 1250000 1600000 2400000 65 70 75 80 90 95 105 110 115 120 130 170M5408* 170M5409* 170M5410* 170M5411* 170M5412* 170M5413* 170M5414* 170M5415* 170M5416* 170M5417* 170M5418* 170M5458* 170M5459* 170M5460* 170M5461* 170M5462* 170M5463* 170M5464* 170M5465* 170M5466* 170M5467* 170M5468* 170M5508* 170M5509* 170M5510* 170M5511* 170M5512* 170M5513* 170M5514* 170M5515* 170M5516* 170M5517* 170M5518* 170M5558* 170M5559* 170M5560* 170M5561* 170M5562* 170M5563* 170M5564* 170M5565* 170M5566* 170M5567* 170M5568* 6 6 6 6 6 6 6 6 6 4 4 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 2.40 2.40 95 100 105 110 115 120 125 130 140 155 160 160 165 175 170M6408* 170M6409* 170M6410* 170M6411* 170M6412* 170M6413* 170M6414* 170M6415* 170M6416* 170M6417* 170M6418* 170M6419* 170M6420 170M6421 170M6458* 170M6459* 170M6460* 170M6461* 170M6462* 170M6463* 170M6464* 170M6465* 170M6466* 170M6467* 170M6468* 170M6469* 170M6470 170M6471 170M6508* 170M6509* 170M6510* 170M6511* 170M6512* 170M6513* 170M6514* 170M6515* 170M6516* 170M6517* 170M6518* 170M6519* 170M6520 170M6521 170M6558* 170M6559* 170M6560* 170M6561* 170M6562* 170M6563* 170M6564* 170M6565* 170M6566* 170M6567* 170M6568* 170M6569* 170M6570 170M6571 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 1.82 1.82 1.82 500 14000 550 19500 630 31000 700 44500 800 69500 900 100000 3 1000 140000 1100 190000 1250 290000 1400 370000 1500 460000 1600 580000 †1800 880000 ‡2000 1150000 *UL Recognized / CSA Component Accepted. 95000 135000 210000 300000 465000 670000 945000 1300000 1950000 2450000 3100000 3900000 †5250000 ‡6350000 Rated voltage †600V ‡550V Data Sheet: 720019 140 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body Flush End Contact —1000-4000A Voltage Rating: 690V (IEC) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Size 4 Rated Current RMSNorm Cool. Rated Current RMSLiquid Cool. 1000 1350 1250 1700 1400 1900 1600 Ordering Information -G/Visual Indicator -GKN/Type K Indicator for Micro 170M7058 170M7078 170M7098 170M7118 170M7059 170M7079 170M7099 170M7119 2 1.80 375 170M7060 170M7080 170M7100 170M7120 2 1.80 220 405 170M7061 170M7081 170M7101 170M7121 2 1.80 3950000 245 445 170M7062 170M7082 170M7102 170M7122 2 1.80 1200000 7800000 275 495 170M7063 170M7083 170M7103 170M7123 2 1.80 4100 2000000 13500000 305 555 170M7064 170M7084 170M7104 170M7124 2 1.80 3500 4700 3250000 22000000 325 585 170M7065 170M7085 170M7105 170M7125 2 1.80 †4000 †5400 4700000 †28000000 355 640 170M7066 170M7086 170M7106 170M7126 2 1.80 Pre-arc Clearing at 660V Watts Loss Norm. Cool. Watts Loss Liquid Cool. 76000 505000 175 315 145000 965000 195 355 205000 1400000 205 2200 305000 2050000 2000 2700 600000 2500 3400 3000 I2t (A2s) -B/Visual Indicator -BKN/Type K Indicator for Micro Carton Qty. 2 Carton Weight (Kg) 1.80 Rated voltage †500V. Liq. Cool. - Liquid cooling. Temperature on the terminals not to exceed 60°C. Data Sheet: 720020 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 141 Bussmann® High Speed Fuses European Style Square Body Flush End Contact — 50-1400A Voltage Rating: 1250V (IEC) 1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information I2t (A2s) Size Rated Current RMS-Amps 50 63 80 100 125 1* Pre-arc Clearing at 1000V Clearing at 1250V 135 215 420 750 1450 815 1300 2500 4450 9000 1100 1750 3350 5950 11500 160 2600 200 5150 250 9200 315 18500 350 27000 400 53000 160 1900 200 3800 250 7750 315 15000 1 350 20000 400 29500 450 42000 500 69500 550 95000 630 130000 250 6500 280 9350 315 13000 350 16500 400 23000 2 450 34000 500 48000 550 62000 630 115000 700 160000 800 245000 †900 360000 †1000 480000 315 9500 350 13500 400 19500 450 31000 500 39000 550 55000 630 83500 3 700 115000 800 205000 900 305000 1000 450000 1100 575000 †1250 810000 †1400 1250000 *UL Recognized / CSA Component Accepted. Individual Fuse Weight: Size 1* = 0.380 Kg Size 1 = 0.580 Kg Size 2 = 0.900 Kg Size 3 = 1.250 Kg 16000 31000 54500 115000 165000 265000 11500 22500 46000 90000 125000 175000 250000 340000 465000 660000 38500 55500 77500 97500 140000 205000 285000 370000 575000 795000 1200000 1750000 2350000 58000 81500 120000 185000 235000 325000 495000 705000 995000 1500000 2150000 2800000 3950000 6000000 Rated voltage Watts Loss 15 20 25 30 35 21000 40 41000 45 73000 55 150000 60 220000 65 335000 70 15500 45 30000 50 61500 60 120000 65 165000 70 235000 75 335000 80 435000 85 590000 95 — 100 51500 65 74500 70 105000 75 135000 80 180000 85 270000 90 380000 95 495000 100 730000 110 1050000 115 1550000 120 — 125 — 135 77500 85 110000 90 160000 95 245000 100 310000 105 435000 110 665000 115 940000 120 1300000 125 1900000 130 2750000 135 3600000 140 — 145 — 150 †1100 ‡1000V ¥1250V -BKN/75 Type K Indicator for Micro -BKN/80 Type K Indicator for Micro -BKN/90 Type K Indicator for Micro -GKN/75 Type K Indicator for Micro -GKN/90 Type K Indicator for Micro 170M3388* 170M3389* 170M3390* 170M3391* 170M3392* 170M3438* 170M3439* 170M3440* 170M3441* 170M3442* — — — — — 170M3488* 170M3489* 170M3490* 170M3491* 170M3492* — — — — — 170M3393* 170M3394* 170M3395* 170M3396* 170M3397* — 170M4388* 170M4389* 170M4390* 170M4391* 170M4392* 170M4393* 170M4394* †170M4395 ‡170M4396 ‡170M4397 170M5388* 170M5389* 170M5390* 170M5391* 170M5392* 170M5393* 170M5394* 170M5395* †170M5396 ‡170M5397 ‡170M5398 — — 170M6338* 170M6339* 170M6340* 170M6341* 170M6342* 170M6343* 170M6344* 170M6345* †170M6346 ‡170M6347 ‡170M6348 ‡170M6349 — — 170M3443* 170M3444* 170M3445* 170M3446* 170M3447* 170M3448* 170M4438* 170M4439* 170M4440* 170M4441* 170M4442* 170M4443* 170M4444* 170M4445* 170M4446* †170M4447 170M5438* 170M5439* 170M5440* 170M5441* 170M5442* 170M5443* 170M5444* 170M5445* 170M5446* †170M5447 ‡170M5448 — — 170M6538* 170M6539* 170M6540* 170M6541* 170M6542* 170M6543* 170M6544* 170M6545* 170M6546* †170M6547 †170M6548 ‡170M6549 — — — — — — — — — — — — — — — — — — — — — — — — 170M5494* 170M5495* 170M5496* 170M5497* 170M5498* 170M5499 170M5500 — — — — — — 170M6494* 170M6495* ¥170M6496 ¥170M6497 ¥170M6498 ¥170M6499 170M6500 170M6501 170M3493* 170M3494* 170M3495* 170M3496* 170M3497* — 170M4488* 170M4489* 170M4490* 170M4491* 170M4492* 170M4493* 170M4494* †170M4495 ‡170M4496 ‡170M4497 170M5588* 170M5589* 170M5590* 170M5591* 170M5592* 170M5593* 170M5594* 170M5595* †170M5596 ‡170M5597 ‡170M5598 — — 170M6588* 170M6589* 170M6590* 170M6591* 170M6592* 170M6593* 170M6594* 170M6595* †170M6596 ‡170M6597 ‡170M6598 ‡170M6599 — — 1 kg = 2.2 lbs. 1 lb = 0.45 kg Data Sheet: 720031 142 — — — — — — — — — — — — — — — — — — — — — — 170M5644* 170M5645* 170M5646* 170M5647* 170M5648* 170M5649 170M5650 — — — — — — 170M6644* 170M6645* ¥170M6646 ¥170M6647 ¥170M6648 ¥170M6649 170M6650 170M6651 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body French Standard — 40-1500A Voltage Rating: 690V (IEC), 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information Watts Loss -E/ Type T Indicator for Micro -EKN/ Type K Indicator for Micro Carton Qty. Carton Weight (Kg) I2t (A2s) Size 1* 1 2 3 Rated Current RMS-Amps Pre-arc Clearing at 660V 40 50 63 80 100 40 77 115 185 360 270 515 770 1250 2450 9 11 14 18 21 170M3308* 170M3309* 170M3310* 170M3311* 170M3312* 170M3358* 170M3359* 170M3360* 170M3361* 170M3362* 1 1 1 1 1 0.300 0.300 0.300 0.300 0.300 125 160 550 1100 3700 7500 26 30 200 250 315 350 400 450 500 200 250 315 350 400 450 500 550 630 700 800 400 450 500 550 630 700 800 900 1000 500 550 630 700 800 900 1000 1100 1250 1400 1500 2200 4200 7000 10000 15000 21000 27000 1650 3100 6200 8500 13500 17000 25000 34000 52000 69500 105000 11000 15500 21500 28000 41000 60500 86000 125000 180000 14000 19500 31000 44500 69500 100000 140000 190000 290000 370000 460000 15000 28500 46500 68500 105000 140000 180000 11500 21000 42000 59000 91500 120000 170000 230000 350000 465000 725000 74000 105000 145000 190000 275000 405000 575000 840000 1250000 95000 135000 210000 300000 465000 670000 945000 1300000 1950000 2450000 3100000 35 40 50 55 60 65 70 45 55 58 60 65 70 72 75 80 85 95 65 70 75 80 90 95 105 110 115 95 100 105 110 115 120 125 130 140 155 160 170M3313* 170M3314* 170M3315* 170M3316* 170M331z7* 170M3318* 170M3319* 170M3320* 170M3321* 170M4308* 170M4309* 170M4310* 170M4311* 170M4312* 170M4313* 170M4314* 170M4315* 170M4316* 170M4317* 170M4318* 170M5308* 170M5309* 170M5310* 170M5311* 170M5312* 170M5313* 170M5314* 170M5315* 170M5316* 170M6308* 170M6309* 170M6310* 170M6311* 170M6312* 170M6313* 170M6314* 170M6315* 170M6316* 170M6317* 170M6318* 170M3363* 170M3364* 170M3365* 170M3366* 170M3367* 170M3368* 170M3369* 170M3370* 170M3371* 170M4358* 170M4359* 170M4360* 170M4361* 170M4362* 170M4363* 170M4364* 170M4365* 170M4366* 170M4367* 170M4368* 170M5358* 170M5359* 170M5360* 170M5361* 170M5362* 170M5363* 170M5364* 170M5365* 170M5366* 170M6358* 170M6359* 170M6360* 170M6361* 170M6362* 170M6363* 170M6364* 170M6365* 170M6366* 170M6367* 170M6368* 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.300 0.300 0.300 0.300 0.300 0.300 0.300 0.300 0.300 0.470 0.470 0.470 0.470 0.470 0.470 0.470 0.470 0.470 0.470 0.470 0.620 0.620 0.620 0.620 0.620 0.620 0.620 0.620 0.620 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.930 *UL Recognized / CSA Component Accepted. Data Sheet: 720022 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 143 Bussmann® High Speed Fuses European Style Square Body US Standard — 40-2000A Voltage Rating: 690V (IEC), 700V (UL) Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information -FU/Without Indicator -FKE/Type K Indicator for Micro -FU/115 Without Indicator -FKE/115 Type K Indicator for Micro Carton Qty. Carton Weight (Kg) 9 11 14 18 21 26 30 170M3608* 170M3609* 170M3610* 170M3611* 170M3612* 170M3613* 170M3614* 170M3658* 170M3659* 170M3660* 170M3661* 170M3662* 170M3663* 170M3664* 170M3708* 170M3709* 170M3710* 170M3711* 170M3712* 170M3713* 170M3714* 170M3758* 170M3759* 170M3760* 170M3761* 170M3762* 170M3763* 170M3764* 1 1 1 1 1 1 1 0.340 0.340 0.340 0.340 0.340 0.340 0.340 35 40 50 55 60 65 70 75 80 45 55 58 60 65 70 72 75 80 85 95 100 65 70 75 80 90 95 105 110 115 120 130 95 100 105 110 115 120 125 130 140 155 160 160 165 175 170M3615* 170M3616* 170M3617* 170M3618* 170M3619* 170M3620* 170M3621* 170M3622* 170M3623* 170M4608* 170M4609* 170M4610* 170M4611* 170M4612* 170M4613* 170M4614* 170M4615* 170M4616* 170M4617* 170M4618* 170M4619 170M5608* 170M5609* 170M5610* 170M5611* 170M5612* 170M5613* 170M5614* 170M5615* 170M5616* 170M5617* 170M5618* 170M6608* 170M6609* 170M6610* 170M6611* 170M6612* 170M6613* 170M6614* 170M6615* 170M6616* 170M6617* 170M6618* 170M6619* 170M6620 170M6621 170M3665* 170M3666* 170M3667* 170M3668* 170M3669* 170M3670* 170M3671* 170M3672* 170M3673* 170M4658* 170M4659* 170M4660* 170M4661* 170M4662* 170M4663* 170M4664* 170M4665* 170M4666* 170M4667* 170M4668* 170M4669 170M5658* 170M5659* 170M5660* 170M5661* 170M5662* 170M5663* 170M5664* 170M5665* 170M5666* 170M5667* 170M5668* 170M6658* 170M6659* 170M6660* 170M6661* 170M6662* 170M6663* 170M6664* 170M6665* 170M6666* 170M6667* 170M6668* 170M6669* 170M6670 170M6671 170M3715* 170M3716* 170M3717* 170M3718* 170M3719* 170M3720* 170M3721* 170M3722* 170M3723* 170M4708* 170M4709* 170M4710* 170M4711* 170M4712* 170M4713* 170M4714* 170M4715* 170M4716* 170M4717* 170M4718* 170M4719 170M5708* 170M5709* 170M5710* 170M5711* 170M5712* 170M5713* 170M5714* 170M5715* 170M5716* 170M5717* 170M5718* 170M6708* 170M6709* 170M6710* 170M6711* 170M6712* 170M6713* 170M6714* 170M6715* 170M6716* 170M6717* 170M6718* 170M6719* 170M6720 170M6721 170M3765* 170M3766* 170M3767* 170M3768* 170M3769* 170M3770* 170M3771* 170M3772* 170M3773* 170M4758* 170M4759* 170M4760* 170M4761* 170M4762* 170M4763* 170M4764* 170M4765* 170M4766* 170M4767* 170M4768* 170M4769 170M5758* 170M5759* 170M5760* 170M5761* 170M5762* 170M5763* 170M5764* 170M5765* 170M5766* 170M5767* 170M5768* 170M6758* 170M6759* 170M6760* 170M6761* 170M6762* 170M6763* 170M6764* 170M6765* 170M6766* 170M6767* 170M6768* 170M6769* 170M6770 170M6771 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.340 0.340 0.340 0.340 0.340 0.340 0.340 0.340 0.340 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.500 0.630 0.630 0.630 0.630 0.630 0.630 0.630 0.630 0.630 0.630 0.630 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 0.950 I t (A s) 2 Size Rated Current RMS-Amps 40 50 63 80 100 125 160 2 Pre-arc Clearing at 660V 40 77 115 185 360 550 1100 270 515 770 1250 2450 3700 7500 200 2200 15000 250 4200 28500 315 7000 46500 350 10000 68500 400 15000 105000 450 21000 140000 500 27000 180000 550 34000 230000 630 48500 325000 200 1650 11500 250 3100 21000 315 6200 42000 350 8500 59000 400 13500 91500 450 17000 120000 1 500 25000 170000 550 34000 230000 630 52000 350000 700 69500 465000 800 105000 725000 ‡900 155000 ‡850000 400 11000 74000 450 15500 105000 500 21500 145000 550 28000 190000 630 41000 275000 2 700 60500 405000 800 86000 575000 900 125000 840000 1000 180000 1250000 1100 245000 1600000 1250 365000 2400000 500 14000 95000 550 19500 135000 630 31000 210000 700 44500 300000 800 69500 465000 900 100000 670000 1000 140000 945000 3 1100 190000 1300000 1250 290000 1950000 1400 370000 2450000 1500 460000 3100000 1600 580000 3900000 †1800 880000 †5250000 ‡2000 1150000 ‡6350000 *UL Recognized / CSA Component Accepted. Rated voltage †600V ‡550V 1* Watts Loss Data Sheet: 720023 144 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses European Style Square Body US Standard — 50-1400A Voltage Rating: 1250V (IEC), 1300V (UL) Interrupting Rating: 100kA RMS Symmetrical Agency Information: CSA Component Acceptance UL Recognized, Std. 248-13 Watts loss provided at rated current. Microswitch indicator ordered separately. See bottom of page 146. Electrical Characteristics Ordering Information I2t (A2s) Size 1* Rated Current RMS-Amps 50 63 80 100 125 160 Pre-arc Clearing at 1000V Clearing at 1250V 135 215 420 750 1450 2600 815 1300 2500 4450 9000 16000 1100 1750 3350 5950 11500 21000 200 5150 31000 250 9200 54500 315 18500 115000 350 27000 165000 160 1900 11500 200 3800 22500 250 7750 46000 315 15000 90000 350 20000 125000 1 400 29500 175000 450 42000 250000 †500 69500 340000 †550 95000 465000 ‡630 130000 660000 250 6500 38500 280 9350 55500 315 13000 77500 350 16500 97500 400 23000 140000 450 34000 205000 2 500 48000 285000 550 62000 370000 630 115000 575000 †700 160000 795000 †800 245000 1200000 †900 360000 1750000 ‡1000 480000 2350000 315 9500 58000 350 13500 81500 400 19500 120000 450 31000 185000 500 39000 235000 550 55000 325000 630 83500 495000 3 700 115000 705000 800 205000 995000 900 305000 1500000 ¥1000 450000 2150000 ¥1100 575000 2800000 ¥1250 810000 3950000 ¥1400 1250000 6000000 *UL Recognized / CSA Component Accepted. Rated voltage ¥ UL Recognized / CSA Component Accepted at 1000V 41000 73000 150000 220000 15500 30000 61500 120000 165000 235000 335000 435000 590000 — 51500 74500 105000 135000 180000 270000 380000 495000 730000 1050000 1550000 — — 77500 110000 160000 245000 310000 435000 665000 940000 1300000 1900000 2750000 3600000 — — †1100V ‡1000V Watts Loss 15 20 25 30 35 40 45 55 60 65 45 50 60 65 70 75 80 85 95 100 65 70 75 80 85 90 95 100 110 115 120 125 135 185 90 95 100 105 110 115 120 125 130 135 140 145 150 -FU/115 Without Indicator -FKE/115 Type K Indicator for Micro Carton Qty. Carton Weight (Kg) 170M3688* 170M3689* 170M3690* 170M3691* 170M3692* 170M3738* 170M3739* 170M3740* 170M3741* 170M3742* 1 1 1 1 1 0.425 0.425 0.425 0.425 0.425 170M3693* 170M3694* 170M3695* 170M3696* 170M3697* 170M4688* 170M4689* 170M4690* 170M4691* 170M4692* 170M4693* 170M4694* 170M4695 170M4696 170M4697 170M5688* 170M5689* 170M5690* 170M5691* 170M5692* 170M5693* 170M5694* 170M5695* 170M5696* 170M5697 170M5698 170M5699 170M5700 170M6688* 170M6689* 170M6690* 170M6691* 170M6692* 170M6693* 170M6694* 170M6695* 170M6696* 170M6697* †170M6698* †170M6699* ‡170M6700* ‡170M6701* 170M3743* 170M3744* 170M3745* 170M3746* 170M3747* 170M4738* 170M4739* 170M4740* 170M4741* 170M4742* 170M4743* 170M4744* 170M4745 170M4746 170M4747 170M5738* 170M5739* 170M5740* 170M5741* 170M5742* 170M5743* 170M5744* 170M5745* 170M5746* 170M5747 170M5748 170M5749 170M5750 170M6738* 170M6739* 170M6740* 170M6741* 170M6742* 170M6743* 170M6744* 170M6745* 170M6746* 170M6747* †170M6748* †170M6749* ‡170M6750* ‡170M6751* 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.425 0.425 0.425 0.425 0.425 0.675 0.675 0.675 0.675 0.675 0.675 0.675 0.675 0.675 0.675 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.250 Data Sheet: 720032 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 145 Bussmann® High Speed Fuses Indicator System Indicators Typower ZILOX fuses are available with three different indicator systems. Visual Indicator The indicator situated in one cover plate is clearly visible as soon as the fuse has operated. The minimum voltage for operating the indicator is 20V. Type T Indicator The indicator is situated on one cover plate with a cover plate tag to accommodate an auxiliary switch. The minimum voltage for operating the indicator is 20V. A special low voltage indicator (1.5V) is available on request. Type K Indicator This indicator is situated on the fuse body. It is covered by an adaptor for snap-on mounting of an auxiliary switch. The operating voltage of the indicator is 1.5V. As a matter of safety, the factory mounted adaptor must not be removed from the fuse. Microswitch The Typower ZILOX fuses with either type T indicator or type K indicator can be equipped with a microswitch for remote electrical indication of fuse operations. All microswitches have one normally open and one normally closed contact. Ratings are 2A, 250Vac. Microswitch 170H0235 170H0236 170H0237 170H0238 170H0069 6.3 x 0.8 mm Lugs ≈ ≈ ≈ ≈ 000 00 1* 1 2 3 Indicator Type T T T T K ≈ DIN 43 653 Size 2.8 x 0.5 mm Lugs Type T 170H0236 170H0238 170H0235 170H0237 170H0235 170H0237 170H0235 170H0237 170H0235 170H0237 170H0235 170H0237 4 23 24 Type K DIN 43 620 Type T 170H0236 170H0238 Type K French Style Type T Type K Flush End Type T US Style Type K Type K 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0069 170H0235 170H0237 170H0069 170H0235 170H0237 170H0069 170H0069 170H0069 170H0235 170H0237 170H0236 170H0238 170H0236 170H0238 170H0236 170H0238 170H0236 170H0238 170H0236 170H0238 170H0069 170H0069 170H0069 Data Sheet: 720034 146 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses Fuse Bases (Blocks) DIN 43 653 Fuse Bases For the Typower ZILOX fuses according to DIN 43 653, the following fuse bases are available: Part Number 170H3003 170H3004 170H3005 170H3006 Max. Voltage 1000V 1000V 1400V 1400V Rated Current 630A 1250A 630A 1250A 170H3003 Center Distance 80mm 80mm 110mm 110mm The fuse bases rated 1250A can also be used for the fuses with higher rated current if the maximum load current is derated according to the table below: Fuse Rating 1400A 1500A 1600A 1800A 2000A Max. Load Current In Fuse Base 1325A 1400A 1500A 1650A 1800A Fixed Center Base Style Max. Voltage 170H1007* 1000V 170H1013* 660V *UL Recognized to UL 512. Max. Fuse Current Rating 400A 200A 170H1007 Fuse Size 00, 000 0000,000 Universal Fuse Bases For the Typower ZILOX fuses according to DIN 43 653, French style and North American style, the following fuse bases are available: Modular Base Style 1BS101 1BS102 1BS103 1BS104 BH-0XXX BH-1XXX BH-2XXX BH-3XXX Max. Voltage 600V 600V 600V 600V 700V 2500V 5000V 1250V Max. Fuse Current Rating 100A 400A 400A 600A 100A 400A 400A 700A BIF Document 1206 1207 1208 1209 1200 1201 1202 1203 1BS104 Universal fuse bases are UL Recognized to UL 512 and meet the spacing requirements of UL 347. Contact Bussmann sales representative for more complete ordering information. DIN 43 620 Fuse Bases For fuse bases used with Typower ZILOX fuses according to DIN 43 620, please contact your local Bussmann sales representative. Data Sheet: 720036 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 147 Bussmann® High Speed Fuses British Standard BS88: Part 4 Voltage Rating 240Vac/150Vdc 6 to 900A 690Vac/450Vdc 6 to 700A All Bussmann British Style fuses are tested to IEC 269: Part 4. This standard requires a test voltage which is 10% higher than the rated voltage. In North America, fuses are required to clear only their rated voltage. Designed and tested to: • BS 88: Part 4 • IEC 60269: Part 4 • UL Recognized, Std. 248-13 Bussmann British Style products use innovative arc quenching techniques and high grade materials to provide: • Minimal energy let-thru (I2t) • Excellent DC performance • Good surge withstand profile 240Vac/150Vdc - 6 to 900A Accessories Trip-indicator fuses are available for use in parallel with the main fuse. Indicator fuses can be attached to the associated fuselink, or mounted separately in panel-mounted fuseclips. In addition, a push-on adaptor and microswitch attachment are available, to provide remote indication. Fuseblocks are also available for most applications. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc. Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics Ordering Information I2t (A2 SEC) Size LCT LET LMT LMMT Rated Current RMS-Amps 6 10 12 16 20 25 32 35 50 63 80 100 125 160 180 160 200 250 315 355 400 450 400 500 630 710 800 900 Pre-arc Clearing at 120V Clearing at 240V 2 3.8 7 20 25 18 32 50 100 180 300 600 600 1100 1600 1100 1500 3200 6000 8000 14000 18000 6000 14000 24000 32000 52000 75000 6 12 22 50 80 120 200 320 500 1100 1900 3800 3800 7000 12000 7000 10000 20000 35000 50000 70000 100000 35000 80000 150000 200000 300000 400000 9 22 32 100 160 250 450 600 1400 2200 3800 7500 7500 16000 29000 16000 20000 40000 75000 100000 160000 220000 80000 170000 300000 460000 600000 800000 Watts Loss Part Number Carton Qty. 1.0 2.5 2.5 2.5 4.0 4.0 5.0 5.0 7.0 9.0 10.0 10.0 16.0 20.0 21.0 17.0 28.0 28.0 35.0 35.0 40.0 42.0 60.0 64.0 75.0 77.0 82.0 97.0 6LCT 10LCT 12LCT 16LCT 20LCT 25LET 32LET 35LET 50LET 63LET 80LET 100LET 125LET 160LET 180LETa 160LMT 200LMT 250LMT 315LMT 355LMT 400LMT 450LMT 400LMMT 500LMMT 630LMMT 710LMMT 800LMMT 900LMMT 20 20 20 20 20 10 10 10 10 10 10 10 10 10 10 1 1 1 1 1 1 1 1 1 1 1 1 1 Carton Weight (Kg) Note: 7LET, 10LET, 12LET and 16LET are available for replacement purposes on existing equipment (not UL recognized). Data Sheet: 720004 148 For complete specification data, call Bussmann Information Fax ~636.527.1450 0.110 0.110 0.110 0.110 0.110 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.310 0.180 0.180 0.180 0.180 0.180 0.180 0.180 0.370 0.370 0.370 0.370 0.370 0.370 Bussmann® High Speed Fuses British Standard BS88: Part 4 690Vac/500Vdc 6-700A Interrupting Rating: 200kA RMS Symmetrical. UL Recognized, Std. 248-13, Watts loss provided at rated current. MT, MMT and additional ratings of ET and EET are available for replacement purposes on existing equipment and are BS 88: Part 4 approved. Electrical Characteristics Ordering Information I2t (A2 SEC) Size CT ET FE EET FEE FM FMM MT† MMT† Rated Current RMS-Amps 6 10 12 16 20 25 32 35 40 45 56 63 80 35 40 45 50 63 71 80 90 100 90 110 140 160 100 120 140 160 180 200 180 200 225 250 280 315 350 400 450 500 550 630 700 160 180 200 250 280 315 355 180 200 225 280 315 355 400 450 500 560 630 710 Pre-arc 1.8 7 10 16 32 25 32 52 103 103 135 171 360 33 52 76 103 135 210 250 360 470 490 600 1050 1500 400 540 850 1000 1400 1900 1400 2600 3700 5200 7000 10000 15000 10000 15000 20000 30000 45000 60000 2400 3800 6000 11500 16500 19000 22000 1650 2200 3700 6600 8600 13500 21000 30000 42000 60000 68500 78000 Clearing at 415V 8.5 30 40 66 150 150 190 310 600 680 950 1200 2500 130 180 270 380 480 600 900 1300 1800 3000 4000 7000 10000 1600 1900 2500 3700 5300 7100 7500 10500 14500 20500 30500 40000 60000 40000 60000 82000 120000 180000 245000 15000 25000 40000 80000 100000 125000 160000 12000 16000 26000 47000 62000 97000 150000 220000 300000 430000 500000 600000 Clearing at 660V 12 48 65 110 220 250 350 500 900 1100 1500 2000 4000 200 300 450 600 750 950 1500 2100 2800 4500 6500 12000 17000 2400 3100 3800 5700 8400 11400 13500 18500 26500 37500 55000 77000 105000 72500 105000 150000 215000 310000 420000 25000 38000 58000 110000 150000 180000 200000 18000 23000 40000 70000 91000 140000 220000 320000 450000 640000 720000 850000 Watts Loss 2 3 3 7 7 7 11 11 9 11 14 16 18 9 9 11 11 12 17 20 20 23 19 27 35 39 24 32 36 46 46 52 40 40 44 48 48 55 55 85 90 100 100 100 120 26 26 27 32 35 42 51 42 42 42 47 51 54 60 57 64 64 86 105 Part Number Carton Qty. 6CT 10CT 12CT 16CT 20CT 25ET 32ET 35ET 40ET 45ET 56ET 63ET 80ET 35FE 40FE 45FE 50FE 63FE 71FE 80FE 90FE 100FE 90EET 110EET 140EET 160EET 100FEE 120FEE 140FEE 160FEE 180FEE 200FEE 180FM 200FM 225FM 250FM 280FM 315FM 350FM 400FMM 450FMM 500FMM 550FMM 630FMM 700FMM 160MT 180MT 200MT 250MT 280MT 315MT 355MT 180MMT 200MMT 225MMT 280MMT 315MMT 355MMT 400MMT 450MMT 500MMT 560MMT 630MMT 710MMT 20 20 20 20 20 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Carton Weight (Kg) 0.160 0.160 0.160 0.160 0.160 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.420 0.450 0.450 0.450 0.450 0.450 0.450 0.450 0.450 0.450 0.450 0.240 0.240 0.240 0.240 0.240 0.240 0.240 0.450 0.450 0.450 0.450 0.450 0.450 0.260 0.260 0.260 0.260 0.260 0.260 0.260 .0470 .0470 .0470 .0470 .0470 .0470 .0470 .0470 .0470 .0470 .0470 .0470 Note: 8ET, 12ET, 15ET, 20ET, 65EET and 75EET are available for replacement purposes on existing equipment (not UL recognized). † 350Vdc (IEC) rating. No UL Recognition. Data Sheet: 720024 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 149 Bussmann® High Speed Fuses Indicator System and Fuse Bases (Blocks) Microswitch and Adaptor Type MAI Current Rating: ac 50/60Hz resistive load @ 250 VRMS ac 50/60Hz resistive load @ 127 VRMS Trip Indicator 4A 6A dc, resistive load @ 110 Vdc dc, resistive load @ 30 Vdc 0.7 2 Maximum Working Voltage: Contact-to-contact (RMS) Contact-to-contact (RMS) 2.8 2.4 1000V 1500V 3.6 5.2 5.2 44 36 Trip-indicator fuselinks are available for use in parallel with the main fuselinks. They can either be attached to the associated fuselink or mounted separately in panel mounted fuse clips, Part No. CL1. A push-on adaptor and microswitch attachment is available for use with the trip indicator to give the facility of remote indication, reference MAI or MBI. 9.5 NO NC NC 21 NO 3.6 44 36 MAI MAI 21 or or MBI MBI Universal and Stud Fuseblocks Fuse ratings of 20A and below cannot usually accommodate a trip fuselink in parallel. Where trip indicator fuselinks are to be attached to the main fuselink, an accessory pack comprising a pair of mounting clips and an appropriate trip indicator fuselink will be required. The ordering code references for these packs are listed below: Fuse Type ET EET FE FEE LET Order Ref. EC-600 EC-600 EC-600 EC-600 EC-250 Fuse Type FM FMM LMT LMMT A 0.8 Order Ref. MC-600 MC-600 MC-250 MC-250 Dimensions in mm. 1mm = 0.0394∑ 1∑ = 25.4mm Stud Fuseblocks Part No. C5268-1 C5268-2 C5268-3 C5268-4 C5268-5 Trip-indicator Fuselink Data Dim. ‘A’ Voltage Type Max. Rating TI250 37.6 250 TI500 47.5 500 TI600 55.7 600 TI700 61.8 700 Universal Fuseblocks Modular Max. Base Voltage 1BS101 600V 1BS102 600V 1BS103 600V 1BS104 600V 6 21 6.35 6 Type TI1100 TI1500 TI2000 TI2500 Dim. ‘A’ Max. 98.4 120.8 147.5 198.3 Voltage Rating 1100 1500 2000 2500 Stud Height 1.00∑ 1.75∑ 0.75∑ 1.00∑ 1.75∑ Stud Dia. & Threads fiΩ¡§-18 fiΩ¡§-18 fiΩ¡§-18 ⁄Ω¢-20 ⁄Ω¢-20 Max. Fuse Current Rating 100A 400A 400A 600A Data Sheet: 720037 150 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet 1206 1207 1208 1209 Bussmann® High Speed Fuses Ferrule Style Voltage Rating 150Vac/dc 5 to 60A 250Vac/dc* 1 to 50A 500Vac/dc* 0.25 to 30A 600 ac/400 dc 6 to 32A 700Vac/dc** 1 to 50A 700Vac 1 to 100A 750Vac/dc 5 to 60A 1000 ac/800 dc 20 to 30A 1250 ac/1000 dc 20 to 30A 1500 ac/1000 dc 8 to 15A 2000/1000Vac/dc *dc is for 5-30A **500Vdc for 63-100A 2 to 6A Select Fuses designed and tested to: • IEC 60269: Part 4 • UL Recognized, Std. 248-13 Bussmann offers a full line of Ferrule Style (cylindrical and clip-mounted) fuses, designed and tested to meet standards and requirements in various locations around the world. Their unique design and construction provide: • Superior cycling capability • Low energy let-thru (I2t) Ferrule fuses provide an excellent solution for small UPS, small AC drives and other low power applications where space is at a premium. Accessories Ferrule fuses may be mounted in fuse clips, fuseholders, fuseblocks or fused switches. A variety of products are available to suit most end-use requirements. All Bussmann Ferrule fuses—except 690V—have been tested at their rated voltage. The 690V Ferrule fuse has been tested to the IEC 60269 standard, which requires clearing at the rated voltage +5%. FWA 150Vac/150Vdc Interrupting Rating: 100kA RMS Symmetrical. Agency Information: UL Recognized, 150V, Std. 248-13 Watts loss provided at rated current. Electrical Characteristics Ordering Information I2t (A2 SEC) Pre-arc Clearing at 150V 5 1.6 8 1 10 3.6 16 10 x 38 mm 15 14 (⁄‹Ω£™∑) 20 Size 21 x 51 mm (⁄‹Ω¡§∑) Rated Current RMS-Amps Watts Loss Part Number Carton Qty. FWA-5A10F 10 Carton Weight (Kg) 0.100 2.7 FWA-10A10F 10 0.100 55 3.3 FWA-15A10F 10 0.100 33 130 3.8 FWA-20A10F 10 0.100 25 58 220 4.9 FWA-25A10F 10 0.100 30 100 400 4.9 FWA-30A10F 10 0.100 35 75 800 4.5 FWA-35A21F 10 0.600 40 100 1000 5.1 FWA-40A21F 10 0.600 45 130 1300 6 FWA-45A21F 10 0.600 50 170 1600 7.3 FWA-50A21F 10 0.600 60 250 2400 8.0 FWA-60A21F 10 0.600 Data Sheet: 720003 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 151 Bussmann® High Speed Fuses Ferrule Style FWX 250Vac/250Vdc (250Vdc on 5 through 30) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 250V, Std. 248-13 & CSA Component Acceptance Watts loss provided at rated current. Electrical Characteristics Ordering Information I2t (A2 SEC) Size 14 ≈ 51mm Rated Current RMS-Amps Pre-arc Clearing at 250V Watts Loss Part Number Carton Qty. 1 — — — FWX-1A14F 10 0.225 2 — — — FWX-2A14F 10 0.225 3 — — — FWX-3A14F 10 0.225 4 — — — FWX-4A14F 10 0.225 5 1.6 13 1.3 FWX-5A14F 10 0.225 10 3.6 24 3.4 FWX-10A14F 10 0.225 15 14 83 3.8 FWX-15A14F 10 0.225 20 33 200 4.6 FWX-20A14F 10 0.225 25 58 300 5.3 FWX-25A14F 10 0.225 30 100 500 5.9 FWX-30A14F 10 0.225 50 200 1800 5.7 FWX-50A14F 10 0.225 Fuse Block: 1976 - (pole) Data Sheet: 1210 Carton Weight (Kg) Data Sheet: 720006 FWH 500Vac/500Vdc Interrupting Rating: 6 mm ≈ 32 mm (Interrupting rating varies—See Data Sheet for details) 14 mm x 51 mm (200kA RMS Symmetrical). Electrical Characteristics Agency Information: UL Recognized, 500V, Std. 248-13 & CSA Component Acceptance Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Ordering Information I2t (A2 SEC) Size 6 x 32 mm (⁄Ω¢∑ ≈ 1⁄Ω¢∑) 14 ≈ 51mm (·Ω¡§∑) Rated Current RMS-Amps 0.25 0.5 1 2 3.15 5 6.3 7 10 12.5 15 16 20 25 30 1 2 3 4 5 6 10 12 15 20 25 30 Pre-arc Clearing at 500V 0.01 0.05 0.4 1.3 3.1 15 36 50 9.9 20 44 48 75 126 145 — — — — 1.6 1.6 3.6 — 10 26 49 58 0.05 0.25 2 3.5 7.7 40 90 125 139 60 146 177 259 345 430 — — — — 6.4 6.4 13 — 40 96 191 232 Watts Loss Part Number 2.7 1.2 1.7 3.2 2.9 2.1 2.3 2.5 2.86 3.53 3.08 4.48 4.26 — — — — 2.3 — 1.5 1.5 4 — 5.5 6 7 9 FWH-.250A6F* FWH-.500A6F* FWH-001A6F* FWH-002A6F* FWH-3.15A6F* FWH-005A6F* FWH-6.30A6F* FWH-007A6F* FWH-010A6F FWH-12.5A6F FWH-015A6F FWH-016A6F FWH-020A6F FWH-025A6F FWH-030A6F FWH-1A14F FWH-2A14F FWH-3A14F FWH-4A14F FWH-5A14F** FWH-6A14F** FWH-10A14F** FWH-12A14F** FWH-15A14F** FWH-20A14F** FWH-25A14F** FWH-30A14F** Data Sheet: 14mm ≈ 51mm, 720008 & 6mm ≈ 32mm, 720038 152 Carton Qty. Carton Weight (Kg) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 *CSA Component Acceptance **UL Recognized & CSA Component Acceptance at 500Vdc For complete specification data, call Bussmann Information Fax ~ 636.527.1450 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.250 0.250 0.250 0.250 0.250 0.250 0.250 0.250 0.250 0.250 0.250 0.250 Bussmann® High Speed Fuses Ferrule Style FWC 600Vac Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 600V, Std. 248-13 Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Ordering Information I2t (A2 SEC) Watts Loss Part Number Carton Qty. 30 1.5 FWC-6A10F 10 0.100 6 50 2.0 FWC-8A10F 10 0.100 10 9 70 2.5 FWC-10A10F 10 0.100 10 x 38 mm 12 15 120 3.0 FWC-12A10F 10 0.100 (⁄‹Ω£™∑ ) 16 25 150 3.5 FWC-16A10F 10 0.100 20 34 260 4.8 FWC-20A10F 10 0.100 25 60 390 6.0 FWC-25A10F 10 0.100 32 95 600 7.5 FWC-32A10F 10 0.100 Size Rated Current RMS-Amps Pre-arc Clearing at 600V 6 4 8 Carton Weight (Kg) 400Vdc UL Recognition: 32A: Interrupting Rating = 50kA 700VdcUL Recognition: 6-25A: Interrupting Rating = 50kA Fuse Block: BM Series Data Sheet: 1104 Data Sheet: 720011 FWP 690V/700V (IEC/UL) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 700V, Std. 248-13 & CSA Component Acceptance. Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Ordering Information I2t (A2 SEC) Watts Loss Part Number Carton Qty. Carton Weight (Kg) — — FWP-1A14F 5 0.113 — — — FWP-2A14F 5 0.113 2.5 — — — FWP-2.5A14F 5 0.113 3 — — — FWP-3A14F 5 0.113 4 — — — FWP-4A14F 5 0.113 5 1.6 4 1.5 FWP-5A14F 10 0.225 6.3 — — — FWP-6.3A14F 10 0.225 10 3.6 10 4 FWP-10A14F 10 0.225 14 x 51mm 15 10 22 5.5 FWP-15A14F 10 0.225 (·Ω¡§∑ ) 20 26 60 6 FWP-20A14F 10 0.225 25 44 130 7 FWP-25A14F 10 0.225 30 58 150 9 FWP-30A14F 10 0.225 32 95 800 7.6 FWP-32A14F 5 0.113 40 110 980 8 FWP-40A14F 5 0.113 50 220 1800 9 FWP-50A14F 5 0.113 Size Rated Current RMS-Amps Pre-arc Clearing at 660V 1 — 2 Fuse Block: 1976 - (pole) Data Sheet: 1210 ▫ CSA Component Acceptance 5-30A Data Sheet: 720025 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 153 Bussmann® High Speed Fuses Ferrule Style FWP 690V/700V (IEC/UL) Interrupting Rating: 200kA RMS Symmetrical. Agency Information: UL Recognized, 700V, Std. 248-13 & CSA Component Acceptance Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Ordering Information I2t (A2 SEC) Rated Current RMS-Amps Watts Loss Part Number 370 4.6 FWP-20A22F 10 0.450 60 560 5.6 FWP-25A22F 10 0.450 32 95 850 7.0 FWP-32A22F 10 0.450 22 ≈ 58 mm 40 185 1350 8.5 FWP-40A22F 10 0.450 (‡Ω•∑ ) 50 155 1120 9.5 FWP-50A22F 10 0.450 63 310 2700 11 FWP-63A22F 10 0.450 80 620 5100 13.5 FWP-80A22F 10 0.450 100 1250 10000 16 FWP-100A22F 10 0.450 Size Pre-arc Clearing at 660V 20 34 25 Carton Qty. Carton Weight (Kg) 500Vdc UL Recognition: Interrupting Rating = 50kA Fuse Block: J70100 - (pole) CR Data Sheet: 1211 Data Sheet: 720026 FWK 750V Size 5-60A Electrical Characteristics Rated I2t (A2S) Current Clearing RMS-Amps Pre-arc at 750 VDC 20 ≈ 127mm (⁄‹Ω¡§∑) 25 ≈ 146mm (1∑) 5 8 10 15 20 25 30 35 40 50 60 8.5 50 95 100 125 400 800 1300 1600 3100 5900 16 100 200 240 315 1100 2600 4300 5300 12000 24000 Interrupting rating 45kA RMS symmetrical. 750Vdc rating for 5 through 60A (Time constant = 10-15 mS). Ordering Information Watts Loss Part Number — — — — — — — — — — — FWK-5A20F FWK-8A20F FWK-10A20F FWK-15A20F FWK-20A20F FWK-25A20F FWK-30A20F FWK-35A25F FWK-40A25F FWK-50A25F FWK-60A25F Dimensions Carton Qty. Carton Weight (kg) Figure Number 10 0.95 Fig. 1 10 1.65 Fig. 2 1 kg = 2.2 lbs. 1 lb = 0.45 kg Data Sheet: 720039 154 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® High Speed Fuses Ferrule Style FWJ 1000Vac Interrupting Rating: 25kA RMS Symmetrical. Agency Information: UL Recognized, 1000Vac/800Vdc, Std. 248-13 Watts loss provided at rated current. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Electrical Characteristics Ordering Information I2t (A2 SEC) Rated Current RMS-Amps Size 14 ≈ 67 mm (·Ω¡§∑) Pre-arc Clearing at 1000V Watts Loss 20 25 Part Number 220 9 FWJ-20A14F 10 25 0.300 33 350 11 FWJ-25A14F 10 30 0.300 52 450 14 FWJ-30A14F 10 0.300 Carton Qty. Carton Weight (Kg) 800Vdc UL Recognition Data Sheet: 720028 FWL/FWS 1250V/1500V/2000V Size Electrical Characteristics Rated I2t (A2S) Current Clearing RMS-Amps Pre-arc at 1000 Vdc ¥2 0.8 ¥6 27 †8 64 †10 118 20 ≈ 127mm †12 170 (⁄‹Ω¡§∑) †15 209 ‡20 675 ‡25 1200 ‡30 1850 Interrupting rating 45kA RMS Symmetrical. Rated voltage (IEC) ¥2000V †1500V ‡1250V 1000Vdc/30kA rating. 2.4 81 192 277 380 500 1550 2760 4300 Ordering Information Watts Loss 4.4 6.7 7.6 3.0 3.4 5.0 5.9 6.5 7.5 Part Number FWS-2A20F FWS-6A20F FWS-8A20F FWS-10A20F FWS-12A20F FWS-15A20F FWL-20A20F FWL-25A20F FWL-30A20F Carton Qty. Carton Weight (kg) 10 1.00 Dimensions Curves Figure Number See Page Fig. 1 page 108 1 kg = 2.2 lbs. 1 lb = 0.45 kg Data Sheet: 720040 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 155 Page 156 BLANK (Do NOT Print) Bussmann® Medium Voltage Fuses and Fuse Links BBU Boric Acid Fuse-Features Construction Principle parts of the replaceable BBU fuse unit are shown in the cross section view. Main operating parts are the silver element, arcing rod, boric acid cylinder, and spring. A glass epoxy tube encloses the assembly. ption is achieved by the action of an arcing rod and a charged spring, elongating the arc through a boric acid chamber upon release by the fuse element. When the fuse operates, the upward motion of the spring forces the top of the arcing rod to penetrate the upper seal, striking the latch mechanism. On indoor applications, this action caused the blown fuse indicator to actuate. When replacing the blown fuse, the end fittings should be removed from the operated fuse unit, and if undamaged, clamped onto the new fuse unit. The use of a pure silver element and Nichrome wire strain element makes the BBU less susceptible to outages caused by vibration, corona corrosion, and aging of the fuse elements. Application The BBU Boric acid Fuse provides effective protection for circuits and equipment which operate on voltage systems up to 34,500V. They can be used on industrial distribution systems and all fuses are designed for use on the following: Power Transformers Feeder Circuits Distribution Transformers Element Melts Vapor Rod withdraws, quenches elongating arc and vaporizing arc at first current zero Boric Acid At high temperatures, boric acid decomposes producing a blast of water vapor and inert boric anhydride. Electrical interruption is caused by the steam extinguishing the arc, as the arc is being elongated through the cylinder. BBU Fuse Construction The components are housed in a fiberglass reinforced resin tube with plated copper contacts. Positive connection is maintained between the arcing rod and contact with a sliding tulip contact. Operation BBU Expulsion Fuses utilize the proven performance of boric acid to create the de-ionizing action needed to interrupt the current. Fault interru- Higher particle turbulence of the boric acid causes the rate of de-ionization in the cylinder to exceed the ionization of the electrical arc. Both high and low current faults are interrupted in the same manner with no foreign material other than the boric acid required. This enables the fuse to interrupt short circuits within one-half cycle and prevents the arc from restriking after a current zero. After interruption, the gases are expelled from the bottom of the fuse. The arching rod is prevented from falling back into its original position by a friction stop at the top of the fuse unit. Metal-enclosed Switchgear Pad Mount Switches BBU Fuse units can be used in indoor applications, and can be used to directly replace competitive equivalent units. BBU End Fittings End Fittings are required to complete the electrical connection between the fuse unit and the live parts and mounting. End fittings are positioned on the top and bottom of the fuse unit. They can be used over again if they remain undamaged. The indoor fittings accept a Muffler attachment to limit noise and contamination to indoor equipment. The blown fuse indicator located on the top end fitting, provides visual indication of a faulted fuse unit. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 157 Bussmann® Medium Voltage Fuses and Fuse Links BBU Boric Acid Fuses for Use Indoors 158 Catalog Number Ampere Rating 5E to 200E BBU-EFID BBU-EFID 15SE to 200SE BBU-EFID 3K to 200K BBU-EFID 5E to 200E BBU-EFID BBU27-50E 12.5 BBU27-65E BBU27-80E BBU27-100E BBU27-125E BBU27-150E BBU27-175E BBU27-200E BBU27-15SE BBU27-20SE BBU27-25SE BBU27-30SE BBU27-40SE BBU27-50SE BBU27-65SE BBU27-80SE 12.5 BBU27-100SE BBU27-125SE BBU27-150SE BBU27-175SE BBU27-200SE BBU38-3K BBU38-6K BBU38-8K BBU38-10K BBU38-12K BBU38-15K BBU38-20K 10 BBU38-30K BBU38-40K BBU38-50K BBU38-65K BBU38-80K BBU38-100K BBU38-140K BBU38-200K BBU38-5E BBU38-7E BBU38-10E BBU38-13E BBU38-15E BBU38-20E BBU38-25E BBU38-30E BBU38-40E BBU38-50E 10 BBU38-65E BBU38-80E BBU38-100E BBU38-125E BBU38-150E BBU38-175E BBU38-200E BBU38-15SE BBU38-20SE BBU38-25SE BBU38-30SE BBU38-40SE BBU38-50SE BBU38-65SE BBU38-80SE 10 BBU38-100SE BBU38-125SE BBU38-150SE BBU38-175SE BBU38-200SE 15SE to 200SE 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 End Fittings Voltage (kV) E E E E E E E E SE SE SE SE SE SE SE SE SE SE SE SE SE k k k k k k k k k k k k k k k E E E E E E E E E E E E E E E E E SE SE SE SE SE SE SE SE SE SE SE SE SE Max. Int. kA Sym Fuse Type 50 65 80 100 125 150 175 200 15 20 25 30 40 50 65 80 100 125 150 175 200 3 6 8 10 12 15 20 30 40 50 65 80 100 140 200 5 7 10 13 15 20 25 30 40 50 65 80 100 125 150 175 200 15 20 25 30 40 50 65 80 100 125 150 175 200 Catalog Number Amps Catalog Number Ampere Rating 3K to 200K BBU-EFID BBU-EFID 5E to 200E BBU-EFID 15SE to 200SE BBU-EFID 3K to 200K BBU-EFID BBU17-3K BBU17-6K BBU17-8K BBU17-10K BBU17-12K BBU17-15K BBU17-20K 14 BBU17-25K BBU17-30K BBU17-40K BBU17-50K BBU17-65K BBU17-80K BBU17-100K BBU17-140K BBU17-200K BBU17-5E BBU17-7E BBU17-10E BBU17-13E BBU17-15E BBU17-20E BBU17-25E BBU17-30E 14 BBU17-40E BBU17-50E BBU17-65E BBU17-80E BBU17-100E BBU17-125E BBU17-150E BBU17-175E BBU17-200E BBU17-15SE BBU17-20SE BBU17-25SE BBU17-30SE BBU17-40SE BBU17-50SE BBU17-65SE 14 BBU17-80SE BBU17-100SE BBU17-125SE BBU17-150SE BBU17-175SE BBU17-200SE BBU27-3K BBU27-6K BBU27-8K BBU27-10K BBU27-12K BBU27-15K BBU27-20K BBU27-25K BBU27-30K 12.5 BBU27-40K BBU27-50K BBU27-65K BBU27-80K BBU27-100K BBU27-140K BBU27-200K BBU27-5E BBU27-7E BBU27-10E BBU27-13E BBU27-15E BBU27-20E BBU27-25E BBU27-30E BBU27-40E Indoor 5E to 200E 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 End Fittings Voltage (kV) k k k k k k k k k k k k k k k k E E E E E E E E E E E E E E E E E SE SE SE SE SE SE SE SE SE SE SE SE SE k k k k k k k k k k k k k k k k E E E E E E E E E Max. Int. kA Sym Fuse Type 3 6 8 10 12 15 20 25 30 40 50 65 80 100 140 200 5 7 10 13 15 20 25 30 40 50 65 80 100 125 150 175 200 15 20 25 30 40 50 65 80 100 125 150 175 200 3 6 8 10 12 15 20 25 30 40 50 65 80 100 140 200 5 7 10 13 15 20 25 30 40 Catalog Number Amps Indoor *Note: Muffler can be ordered separately. Order Catalog number BBU-MFLR. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Medium Voltage Fuses and Fuse Links Bussmann® E-Rated Medium Voltage Fuses: CL-14 & Bolt-In Electrical Characteristics Bussmann Number Ampere Rating Voltage IR Max Sym. # of Barrels Figure # Style ECL055-10E ECL055-15E ECL055-20E ECL055-25E ECL055-30E ECL055-40E ECL055-50E ECL055-65E ECL055-80E ECL055-100E ECL055-125E ECL055-150E ECL055-200E ECL055-250E ECL055-300E ECL055-400E ECL055-450E ECL055-500E ECL055-600E EBI055-750E EBI055-900E 10E 15E 20E 25E 30E 40E 50E 65E 80E 100E 125E 150E 200E 250E 300E 400E 450E 500E 600E 750E 900E 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 5.5kV 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 63kA 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 3 3 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 3 3 3 3 4 4 Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Clip-Lock Bolt-In Bolt-In Part Number Construction Example Catalog Symbol ECL Voltage Rating 055 Ampere Rating 500E 055 = 5.5 kV Catalog Number Cross Reference Bussmann ECL055-10E ECL055-15E ECL055-20E ECL055-25E ECL055-30E ECL055-40E ECL055-50E ECL055-65E ECL055-80E ECL055-100E ECL055-125E ECL055-150E ECL055-200E ECL055-250E ECL055-300E ECL055-400E ECL055-450E ECL055-500E ECL055-600E EBI055-750E EBI055-900E Ferraz-Shawmut New Catalog # A055C1DORO-10E A055C1DORO-15E A055C1DORO-20E A055C1DORO-25E A055C1DORO-30E A055C1DORO-40E A055C1DORO-50E A055C1DORO-65E A055C1DORO-80E A055C1DORO-100E A055C1DORO-125E A055C1DORO-150E A055C1DORO-200E A055C1DORO-250E A055C1DORO-300E A055C1DORO-400E A055C2DORO-450E A055C2DORO-500E A055C2DORO-600E AO55B3DORO-750E AO55B3DORO-900E Ferraz-Shawmut Old Catalog # 225-007-937 225-007-938 225-007-939 225-007-940 225-007-941 225-007-942 225-007-943 225-007-944 225-007-945 225-007-946 225-007-947 225-007-948 225-007-949 225-007-950 225-007-951 225-007-952 225-007-953 225-007-954 225-007-955 A055X750E-4 A055X900E-4 CATALOG SYMBOL: ECL055 & EBI055 E-RATED MEDIUM VOLTAGE FUSES: Meets E requirements per ANSI C37.46 Meets General Purpose requirements per ANSI C37.40 FOR TRANSFORMER AND FEEDER PROTECTION VOLTAGE RATING: 5.5 KV INTERRUPTING RATING: 63KA Maximum Sym. CURRENT LIMITING CONSTRUCTION: • Silver element in a double concentric helical configuration • Silica filler • Silver plated copper terminals and endcaps • Filament wound, glass epoxy fuse tube FEATURES: • General Purpose Fuses. Bussmann’s medium voltage fuses provide general purpose protection and are capable of interrupting fault currents up to 63,000A RMS sym. • Clip-lock and bolt-in style available in double and triple barrel fuse designs. • Indoor and Outdoor Usage. The filament wound, glass epoxy fuse tube provides UV and moisture protection for the fuse. This makes Bussmann’s medium voltage fuses suitable for both indoor and outdoor applications. • Open Fuse Indication. Indicator travel distance is 16mm. • Operating Frequency: 50/60 Hz Current-limiting medium voltage fuses are classified into three categories: Full Range - defined by ANSI as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the minimum continuous current that causes melting of the fusible element(s), when the fuse is applied at the maximum ambient temperature specified by the manufacturer.” It is able to interrupt any normal 60 cycle current that will melt its element. General Purpose - defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the current that causes melting of the fusible element in one hour.” Not all currents fall within this range. It is possible to receive an overcurrent lower than the value given by the one hour criterion. Back-up - defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the rated minimum interrupting current.” The minimum rated interrupting current is the lowest current that the fuse will be able to clear properly. This creates a need to place a low current interrupting device in series with the back-up rated fuse. Data Sheet: 9002 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 159 Medium Voltage Fuses and Fuse Links Bussmann® E-Rated Medium Voltage Fuses: CL-14 Electrical Characteristics Bussmann Number Ampere Rating Voltage IR Max Sym. # of Barrels Figure # Style ECL155-10E 10E 15.5kV 63KA 1 1 Clip-Lock ECL155-15E 15E 15.5kV 63KA 1 1 Clip-Lock ECL155-20E 20E 15.5kV 63KA 1 1 Clip-Lock ECL155-25E 25E 15.5kV 63KA 1 1 Clip-Lock ECL155-30E 30E 15.5kV 63KA 1 1 Clip-Lock ECL155-40E 40E 15.5kV 63KA 1 1 Clip-Lock ECL155-50E 50E 15.5kV 63KA 1 1 Clip-Lock ECL155-65E 65E 15.5kV 63KA 1 2 Clip-Lock ECL155-80E 80E 15.5kV 63KA 1 2 Clip-Lock ECL155-100E 100E 15.5kV 63KA 1 2 Clip-Lock ECL155-125E 125E 15.5kV 63KA 1 2 Clip-Lock ECL155-150E 150E 15.5kV 63KA 2 3 Clip-Lock ECL155-200E 200E 15.5kV 63KA 2 3 Clip-Lock ECL155-250E 250E 15.5kV 50kA 2 3 Clip-Lock ECL155-300E 300E 15.5kV 50kA 2 3 Clip-Lock Part Number Construction Catalog Symbol Voltage Rating Ampere Rating ECL 155 300E Example 155 = 15.5 kV Catalog Number Cross Reference Ferraz-Shawmut New Catalog # Ferraz-Shawmut Old Catalog # ECL155-10E A155C1DORO-10E 225-007-967 ECL155-15E A155C1DORO-15E 225-007-968 ECL155-20E A155C1DORO-20E 225-007-969 ECL155-25E A155C1DORO-25E 225-007-970 ECL155-30E A155C1DORO-30E 225-007-971 ECL155-40E A155C1DORO-40E 225-007-972 ECL155-50E A155C1DORO-50E 225-007-973 ECL155-65E A155C1DORO-65E 225-007-974 ECL155-80E A155C1DORO-80E 225-007-975 ECL155-100E A155C1DORO-100E 225-007-976 ECL155-125E A155C2DORO-125E 225-007-977 ECL155-150E A155C3DORO-150E 225-007-978 ECL155-200E A155C3DORO-200E 225-007-979 ECL155-250E A155C3DORO-250E 225-007-980 ECL155-300E A155C3DORO-300E 225-007-981 Bussmann CATALOG SYMBOL: ECL155 E-RATED MEDIUM VOLTAGE FUSES: Meets E requirements per ANSI C37.46 Meets General Purpose requirements per ANSI C37.40 FOR TRANSFORMER AND FEEDER PROTECTION VOLTAGE RATING: 15.5 KV INTERRUPTING RATING: See table. CURRENT LIMITING CONSTRUCTION: • Silver element in a double concentric helical configuration • Silica filler • Silver plated copper terminals and endcaps • Filament wound, glass epoxy fuse tube FEATURES: • General Purpose Fuses. Bussmann’s medium voltage fuses provide general purpose protection and are capable of interrupting fault currents up to 50,000A RMS sym. • Clip-Lock Double Barrel Fuse Design. • Indoor and Outdoor Usage. The filament wound, glass epoxy fuse tube provides UV and moisture protection for the fuse. This makes Bussmann’s medium voltage fuses suitable for both indoor and outdoor applications. • Open Fuse Indication. Indicator travel distance is 16mm. • Operating Frequency: 50/60 Hz Current-limiting medium voltage fuses are classified into three categories: Full Range - defined by ANSI as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the minimum continuous current that causes melting of the fusible element(s), when the fuse is applied at the maximum ambient temperature specified by the manufacturer.” It is able to interrupt any normal 60 cycle current that will melt its element. General Purpose - defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the current that causes melting of the fusible element in one hour.” Not all currents fall within this range. It is possible to receive an overcurrent lower than the value given by the one hour criterion. Back-up - defined by ANSI C37.40 as “a fuse capable of interrupting all currents from the maximum rated interrupting current down to the rated minimum interrupting current.” The minimum rated interrupting current is the lowest current that the fuse will be able to clear properly. This creates a need to place a low current interrupting device in series with the back-up rated fuse. BIF document: #9004 160 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links R-Rated Fuses for Motor Circuit Protection JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR, & JCR-B R-Rated Medium Voltage Current Limiting 2400V AC — JCK, JCK-A, JCK-B, JCH 4800V AC — JCL, JCL-A, JCL-B, JCG 7200V AC — JCR, JCR-B Max. Design Voltage: 2540Vac — JCK, JCK-A, JCK-B, JCH 5080Vac — JCL, JCL-A JCL-B, JCG 8300Vac — JCR, JCR-B Agency Information: UL Recognized : 2540Vac — JCK, JCK-A 5080Vac — JCL, JCL-A UL Recognized (Guide #MSSS2, File #E96676) Dimensional Data INDICATOR Showing Fuse is Open 0.38" (9.5mm) C INDICATOR Showing Fuse is Open A B Figure 1 Figure 2 Data Sheet: 6001 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 161 Bussmann® Medium Voltage Fuses and Fuse Links R-Rated Fuses for Motor Circuit Protection Specifications Buss Catalog No. Amperage Maximum Design Voltage A Dimensions (Inches) B C Construction Max. Int. Cap. Amps (Asym.) Amps (Sym.) Min. Int. Cap. Amps (Sym.) 2400V; R-Rated; Indoor/Enclosure (See Figure 1) JCK-2R 70 2R 2540V 11.24 3.0 3.0 Single 80,000 50,000 165 JCK-3R 100 3R 2540V 11.24 3.0 3.0 Single 80,000 50,000 220 JCK-4R 130 4R 2540V 11.24 3.0 3.0 Single 80,000 50,000 320 JCK-5R 150 5R 2540V 11.24 3.0 3.0 Single 80,000 50,000 410 JCK-6R 170 6R 2540V 11.24 3.0 3.0 Single 80,000 50,000 480 JCK-9R 200 9R 2540V 11.24 3.0 3.0 Single 80,000 50,000 720 JCK-12R 230 12R 2540V 11.24 3.0 3.0 Single 80,000 50,000 970 JCK-18R 390 18R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,430 JCK-24R 450 24R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,880 2400V; R-Rated; Indoor/Enclosure; With Westinghouse Ampguard Hookeye (See Figure 1) JCK-A-2R 70 2R 2540V 11.24 3.0 3.0 Single 80,000 50,000 165 JCK-A-3R 100 3R 2540V 11.24 3.0 3.0 Single 80,000 50,000 220 JCK-A-4R 130 4R 2540V 11.24 3.0 3.0 Single 80,000 50,000 320 JCK-A-5R 150 5R 27540V 11.24 3.0 3.0 Single 80,000 50,000 410 JCK-A-6R 170 6R 2540V 11.24 3.0 3.0 Single 80,000 50,000 480 JCK-A-9R 200 9R 2540V 11.24 3.0 3.0 Single 80,000 50,000 720 JCK-A-12R 230 12R 2540V 11.24 3.0 3.0 Single 80,000 50,000 970 JCK-A-18R 390 18R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,430 JCK-A-24R 450 24R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,880 2400V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2) JCK-B-30 25 2540V 14.18 12.81 - Single 80,000 50,000 90 JCK-B-2R 70 2R 2540V 14.18 12.81 - Single 80,000 50,000 170 JCK-B-3R 100 3R 2540V 14.18 12.81 - Single 80,000 50,000 245 JCK-B-4R 130 4R 2540V 14.18 12.81 - Single 80,000 50,000 340 JCK-B-5R 150 5R 2540V 14.18 12.81 - Single 80,000 50,000 430 JCK-B-6R 170 6R 2540V 14.18 12.81 - Single 80,000 50,000 500 JCK-B-9R 200 9R 2540V 14.18 12.81 - Single 80,000 50,000 1,000 JCK-B-12R 230 12R 2540V 14.18 12.81 - Single 80,000 50,000 1,250 JCK-B-18R 390 18R 2540V 14.18 12.81 3.56 Double 80,000 50,000 1,700 JCK-B-24R 450 24R 2540V 14.18 12.81 3.56 Double 80,000 50,000 1,210 2400V; R-Rated; Indoor; Hermetically Sealed, Class 1, Group D, Div. 2, Hazardous Locations; For Use with Ampgard Motor Starters (See Figure 1) JCH-30 25 2540V 10.81 3.0 3.0 Single 80,000 50,000 90 JCH-2R 70 2R 2540V 10.81 3.0 3.0 Single 80,000 50,000 170 JCH-3R 100 3R 2540V 10.81 3.0 3.0 Single 80,000 50,000 245 JCH-4R 130 4R 2540V 10.81 3.0 3.0 Single 80,000 50,000 340 JCH-5R 150 5R 2540V 10.81 3.0 3.0 Single 80,000 50,000 430 JCH-6R 170 6R 2540V 10.81 3.0 3.0 Single 80,000 50,000 500 JCH-9R 200 9R 2540V 10.81 3.0 3.0 Single 80,000 50,000 1,000 JCH-12R 230 12R 2540V 10.81 3.0 3.0 Single 80,000 50,000 1,250 JCH-18R 390 18R 2540V 10.81 3.0 3.0 Double 80,000 50,000 1,700 JCH-24R 450 24R 2540V 10.81 3.0 3.0 Double 80,000 50,000 2,100 4800V; R-Rated; Indoor/Enclosure (See Figure 1) JCL-2R 70 2R 5080V 15.76 3.0 3.0 Single 80,000 50,000 165 JCL-3R 100 3R 5080V 15.76 3.0 3.0 Single 80,000 50,000 220 JCL-4R 130 4R 5080V 15.76 3.0 3.0 Single 80,000 50,000 320 JCL-5R 150 5R 5080V 15.76 3.0 3.0 Single 80,000 50,000 410 JCL-6R 170 6R 5080V 15.76 3.0 3.0 Single 80,000 50,000 480 JCL-9R 200 9R 5080V 15.76 3.0 3.0 Single 80,000 50,000 720 JCL-12R 230 12R 5080V 15.76 3.0 3.0 Single 80,000 50,000 970 JCL-18R 390 18R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,430 JCL-24R 450 24R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,880 162 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links R-Rated Fuses for Motor Circuit Protection Specifications Buss Catalog No. Amperage Maximum Design Voltage A Dimensions (Inches) B C Construction Max. Int. Cap. Amps (Asym.) Min. Int. Cap. Amps (Sym.) Amps (Sym.) 4800V; R-Rated; Indoor/Enclosure; With Westinghouse Ampguard Hookeye (See Figure 1) JCL-A-2R 70 2R 5080V 15.76 3.0 3.0 Single 80,000 50,000 165 JCL-A-3R 100 3R 5080V 15.76 3.0 3.0 Single 80,000 50,000 220 JCL-A-4R 130 4R 5080V 15.76 3.0 3.0 Single 80,000 50,000 320 JCL-A-5R 150 5R 5080V 15.76 3.0 3.0 Single 80,000 50,000 410 JCL-A-6R 170 6R 5080V 15.76 3.0 3.0 Single 80,000 50,000 480 JCL-A-9R 200 9R 5080V 15.76 3.0 3.0 Single 80,000 50,000 720 JCL-A-12R 230 12R 5080V 15.76 3.0 3.0 Single 80,000 50,000 970 JCL-A-18R 390 18R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,430 JCL-A-24R 450 24R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,880 4800V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2) JCL-B-30 30 5080V 19.25 17.88 - Single 80,000 50,000 95 JCL-B-2R 70 2R 5080V 19.25 17.88 - Single 80,000 50,000 180 JCL-B-3R 100 3R 5080V 19.25 17.88 - Single 80,000 50,000 270 JCL-B-4R 130 4R 5080V 19.25 17.88 - Single 80,000 50,000 350 JCL-B-5R 150 5R 5080V 19.25 17.88 - Single 80,000 50,000 450 JCL-B-6R 170 6R 5080V 19.25 17.88 - Single 80,000 50,000 540 JCL-B-9R 200 9R 5080V 19.25 17.88 - Single 80,000 50,000 700 JCL-B-12R 230 12R 5080V 19.25 17.88 - Single 80,000 50,000 1,000 JCL-B-18R 390 18R 5080V 19.25 17.88 3.31 Double 80,000 50,000 1,450 JCL-B-24R 450 24R 5080V 19.25 17.88 3.31 Double 80,000 50,000 2,000 4800V; R-Rated; Indoor; Hermetically Sealed, Class 1, Group D, Div. 2, Hazardous Locations; For Use with Ampgard Motor Starters (See Figure 1) JCG-30 30 5080V 15.91 3.0 3.0 Single 80,000 50,000 95 JCG-2R 70 2R 5080V 15.91 3.0 3.0 Single 80,000 50,000 180 JCG-3R 100 3R 5080V 15.91 3.0 3.0 Single 80,000 50,000 270 JCG-4R 130 4R 5080V 15.91 3.0 3.0 Single 80,000 50,000 350 JCG-5R 150 5R 5080V 15.91 3.0 3.0 Single 80,000 50,000 450 JCG-6R 170 6R 5080V 15.91 3.0 3.0 Single 80,000 50,000 540 JCG-9R 200 9R 5080V 15.91 3.0 3.0 Single 80,000 50,000 700 JCG-12R 230 12R 5080V 15.91 3.0 3.0 Single 80,000 50,000 1,000 JCG-A-18R 390 18R 5080V 15.91 3.0 3.0 Double 80,000 50,000 1,450 JCG-A-24R 450 24R 5080V 15.91 3.0 3.0 Double 80,000 50,000 2,000 160 7200V; R-Rated; Indoor/Enclosure; With Ampgard Hookeye (See Figure 1) JCR-A-2R 70 2R 8300V 15.85 3.0 3.0 Single 80,000 50,000 JCR-A-3R 100 3R 8300V 15.85 3.0 3.0 Single 80,000 50,000 250 JCR-A-4R 130 4R 8300V 15.85 3.0 3.0 Single 80,000 50,000 325 JCR-A-5R 150 5R 8300V 15.85 3.0 3.0 Single 80,000 50,000 390 JCR-A-6R 170 6R 8300V 15.85 3.0 3.0 Single 80,000 50,000 500 JCR-A-9R 200 9R 7200V 15.85 3.0 3.0 Single 80,000 50,000 750 JCR-A-12R 230 12R 7200V 15.85 3.0 3.0 Single 80,000 50,000 1,000 JCR-A-18R 390 18R 7200V 15.85 3.0 3.0 Double 80,000 50,000 1,450 JCR-A-24R 450 24R 7200V 15.85 3.0 3.0 Double 80,000 50,000 2,500 7200V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2) JCR-B-2R 70 2R 8300V 19.25 17.88 - Single 80,000 50,000 160 JCR-B-3R 100 3R 8300V 19.25 17.88 - Single 80,000 50,000 250 JCR-B-4R 130 4R 8300V 19.25 17.88 - Single 80,000 50,000 325 JCR-B-5R 150 5R 8300V 19.25 17.88 - Single 80,000 50,000 390 JCR-B-6R 170 6R 8300V 19.25 17.88 - Single 80,000 50,000 500 JCR-B-9R 200 9R 7200V 19.25 17.88 - Single 80,000 50,000 750 JCR-B-12R 230 12R 7200V 19.25 17.88 - Single 80,000 50,000 1,000 JCR-B-18R 390 18R 7200V 19.25 17.88 3.31 Double 80,000 50,000 1,450 JCR-B-24R 450 24R 7200V 19.25 17.88 3.31 Double 80,000 50,000 2,500 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 163 Bussmann® Medium Voltage Fuses and Fuse Links Medium Voltage for Motor Circuit Protection Table of Ratings kV Code Reference Breaking Capacity (kA) 3.6 WJON6 50 5 6.3 10 16 20 25 31.5 40 50 3.6 WDOH6 50 3.6 WFOH6 50 3.6 WDLSJ 50 3.6 WFLSJ 50 3.6 WDFHO 50 3.6 WFFHO 3.6 WKFHO 5.5 VFNHA 60 5.5 VKNHA 60 7.2 WFNHO 7.2 Dimensions Current Rating (A) Length Diameter 7.56∑ (192mm) 1.4∑ (35mm) 50 63 80 100 125 7.56∑ (192mm) 2∑ (51mm) 160 200 11.5∑ (292mm) 3∑ (76mm) 50 63 80 100 125 11.5∑ (292mm) 2∑ (51mm) 160 200 11.5∑ (292mm) 3∑ (76mm) 50 63 80 100 125 10∑ (254mm) 2∑ (51mm) 50 160 200 10∑ (254mm) 3∑ (76mm) 50 250 315 355 400 10∑ (254mm) 3∑ (76mm) 2R-6R 15.86∑ (403mm) 3∑ (76mm) 9R-24R 15.86∑ (403mm) 3∑ (76mm) 40 25 31.5 40 50 63 80 100 125 160 15.86∑ (403mm) 3∑ (76mm) WKNHO 40 200 224 250 315 15.86∑ (403mm) 3∑ (76mm) 7.2 WFMSJ 40 25 31.5 40 50 63 80 125 160 17.40∑ (442mm) 3∑ (76mm) 7.2 WKMSJ 40 200 224 250 315 355 17.40∑ (442mm) 3∑ (76mm) Dimensional Standard BS2692 (TA1) Interchangeable with GEC type K2 PA BS 2692 (TA1) or DIN 43625 DIN 43625 BS 2692 (TA2) N. American Practice BS2692 (TA4) DIN 43625 Catalog Code: kV Code Reference Current Rating Recommended Fuse Clips for Medium Voltage Fuses Clip Dimensions Part No. Fuse Diameter A B A3354710 2 3.74 1.97 2.00 1.18 4.53 1.50 .39 A3354730 3 4.13 2.44 3.00 1.18 5.63 1.50 .39 C D E F G C A G Fuseclips are for single barrel applications only. Are not sold in pairs. F D E B 1A0065 3” Diameter Clip 9078A67G04 3” Diameter Clip 2 CUP ASSEMBLIES PER PACKAGE. DIMENSIONS SHOWN ARE FOR REFERENCE ONLY. 164 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links E-Rated Medium Volt for Transformers and Feeders MV055 and MV155 E-Rated Medium Voltage Fuses Meets E requirements per ANSI C37.46 Meets full range requirements per ANSI C37.40 For Transformer and Feeder Protection Current Limiting Voltage Rating: 5.5 kV and 15.5 kV Interrupting Rating: 50KA Maximum Sym. Construction: Silver ribbon element surrounded by silica filler housed in a fiberglass tube and plated endcaps. An epoxy paint protects the fuse tube from the surrounding environment. Electrical Characteristics 5.5kV Electrical Characteristics 15.5kV Physical Size Max. Clear Clip I2t Length Dia. Center Barrels 2,400 8,000 8,000 11,000 23,000 15.75 2 12 1 31,000 45,000 45,000 90,000 181,000 Part Number MV055F1CAX5E MV055F1CAX7E MV055F1CAX10E MV055F1CAX15E MV055F1CAX20E MV055F1CAX25E MV055F1CAX30E MV055F1CAX40E MV055F1CAX50E MV055F1CAX65E Ampere Rating 5A 7A 10A 15A 20A 25A 30A 40A 50A 65A Min. Melt I2t 180 850 850 2,070 2,370 4,650 9,490 9,490 13,600 30,700 MV055F1DAX10E MV055F1DAX15E MV055F1DAX20E MV055F1DAX25E MV055F1DAX30E MV055F1DAX40E MV055F1DAX50E MV055F1DAX65E MV055F1DAX80E MV055F1DAX100E 10A 15A 20A 25A 30A 40A 50A 65A 80A 100A 850 2,070 2,370 4,650 9,490 9,490 13,600 30,700 54,600 116,200 MV055F1DAX125E MV055F1DAX150E MV055F1DAX175E MV055F1DAX200E 125A 150A 175A 200A 167,400 600,000 218,700 786,000 227,900 1,100,000 15.75 297,600 1,520,000 MV055F2DAX250E MV055F2DAX300E MV055F2DAX350E MV055F2DAX400E MV055F2DAX450E 250A 300A 350A 400A 450A 669,600 874,800 911,600 1,190,400 1,555,000 8,000 12,000 23,000 31,000 45,000 15.75 45,000 90,000 181,000 270,000 580,000 2,400,000 3,149,000 4,376,000 15.75 6,071,000 9,796,000 3 12 1 3 12 1 3 12 2 Min. Melt I2t 180 850 850 2,070 2,370 4,650 9,490 Physical Size Max. Clear Clip I2t Length Dia. Center Barrels 2,900 8,000 8,000 12,000 18.75 2 15 1 23,000 31,000 45,000 Part Number MV155F1CBX5E MV155F1CBX7E MV155F1CBX10E MV155F1CBX15E MV155F1CBX20E MV155F1CBX25E MV155F1CBX30E Ampere Rating 5A 7A 10A 15A 20A 25A 30A MV155F1DBX10E MV155F1DBX15E MV155F1DBX20E MV155F1DBX25E MV155F1DBX30E MV155F1DBX40E MV155F1DBX50E MV155F1DBX65E MV155F1DBX80E MV155F1DBX100E 10A 15A 20A 25A 30A 40A 50A 65A 80A 100A 850 2,070 2,370 4,650 9,490 9,490 13,600 30,700 54,600 116,200 8,000 12,000 23,000 31,000 45,000 45,000 18.75 90,000 181,000 270,000 600,000 MV155F2DBX125E MV155F2DBX150E MV155F2DBX175E MV155F2DBX200E 125A 150A 175A 200A 123,000 218,700 314,700 465,100 677,000 1,287,000 18.75 1,689,000 2,405,000 MV155F1DCX65E MV155F1DCX80E MV155F1DCX100E MV155F2DCX125E MV155F2DCX150E MV155F2DCX175E MV155F2DCX200E 65A 80A 100A 125A 150A 175A 200A 30,700 54,600 116,200 123,000 218,700 314,700 465,100 181,000 270,000 21.75 600,000 677,000 1,287,000 1,689,000 21.75 2,405,000 Data Sheet: 6700 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 3 15 1 3 15 2 3 18 1 3 18 2 Data Sheet: 6701 165 Bussmann® Medium Voltage Fuses and Fuse Links E-Rated Medium Volt for Potential & Sm Power Transformers JCD, JCW, JCE, JCQ, JCI & JCT Current Limiting Indicating/Non-Indicating Plated Ferrules Voltage Rating: (Max. Design) 2750, 5500, 8300, 15,500 Current Ratings: 1/2E through 10E Specifications Buss Catalog No. Amperage Maximum Interrupting Capacity Maximum Design Voltage Construction Amps (Asym.) Amps (Sym.) Dimensions Length Diameter 2400V; E-Rated Fuse; Indicating JCD-⁄Ω™E 0.50E 2750V Single 100,000 63,000 4.50∑ .80∑ JCD-1E 1.00E 2750V Single 63,000 40,000 (114mm) (20.32mm) JCD-2E 2.00E 2750V Single 63,000 40,000 JCD-5E 5.00E 2750V Single 40,000 25,000 2450/5500V; E-Rated Fuse; Non-Indicating JCW-⁄Ω™E 0.50E 2750V/5500V Single 60,000 40,000 JCW-1E 1.00E 2750V/5500V Single 60,000 40,000 JCW-2E 2.00E 2750V/5500V Single 60,000 40,000 7.312∑ 1.563∑ JCW-3E 3.00E 2750V/5500V Single 60,000 40,000 (185.72mm) (39.70mm) JCW-4E 4.00E 2750V/5500V Single 60,000 40,000 JCW-5E 5.00E 2750V/5500V Single 60,000 40,000 50,000 5500V; E-Rated Fuse; Non-Indicating JCE-⁄Ω™E 0.50E 5500V Single 60,000 JCE-1E 1.00E 5500V Single 60,000 50,000 JCE-2E 2.00E 5500V Single 60,000 50,000 5.625” .81” JCE-3E 3.00E 5500V Single 60,000 50,000 (142.88mm) (20.32mm) JCE-4E 4.00E 5500V Single 60,000 50,000 JCE-5E 5.00E 5500V Single 60,000 50,000 5500V; E-Rated Fuse; Indicating JCQ-⁄Ω™E 0.50E 5500V Single 130,000 80,000 JCQ-1E 1.00E 5500V Single 130,000 80,000 JCQ-1⁄Ω™E 1.50E 5500V Single 130,000 80,000 1.6∑ JCQ-3E 3.00E 5500V Single 130,000 80,000 (40.64mm) JCQ-5E 5.00E 5500V Single 130,000 80,000 JCQ-10E 10.00E 5500V Single 130,000 80,000 9.5∑ (241.3mm) 9.44∑ (239.78mm) 8300V; E-Rated Fuse; Indicating JCI-⁄Ω™E 0.50E 8300V Single 130,000 80,000 JCI-3E 3.00E 8300V Single 130,000 80,000 JCI-5E 5.00E 8300V Single 130,000 80,000 JCI-10E 10.00E 8300V Single 130,000 80,000 9.5∑ (241.3mm) 1.6∑ 12.88∑ (327.15mm) (40.64mm) 15,500V; E-Rated Fuse; Indicating JCT-⁄Ω™E 0.50E 15500V Single 130,000 80,000 JCT-1E 1.00E 15500V Single 130,000 80,000 JCT-1⁄Ω™E 1.50E 15500V Single 130,000 80,000 1.6∑ JCT-3E 3.00E 15500V Single 130,000 80,000 (40.64mm) JCT-5E 5.00E 15500V Single 130,000 80,000 JCT-10E 10.00E 15500V Single 130,000 80,000 12.93∑ (328.42mm) 17.5∑ (444.5mm) Fuse clip for 1.6∑ Diameter Fuses - 1A0835. Fuse clip for .81∑ Diameter Fuses - 1A1837. Data Sheet: 6002 166 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links E-Rated Fuses for Trans. & Feeder Protection E-Rated Current Limiting Blown Fuse Indication Construction: Plated Ferrules Voltage Ratings: (Max. Design): 2,750, 5,500, 8,300, 15,500V Current Ratings: ⁄Ω™E through 750E Specifications Buss Catalog No. Amperage Maximum Interrupting Capacity Maximum Design Voltage Construction Amps. (Asym.) Amps. (Sym.) Dimensions Length Diameter 9.19∑ (233.38mm) 2∑ (50.8mm) 9.5” 2.1” 10.81∑ (276.35mm) 3∑ (76.2mm) 11.19∑ (284.18mm) 2∑ (50.8mm) 2400V; E-Rated; Indoor/Enclosure JCX-⁄Ω™E ⁄Ω™E 2750V Single 60,000 40,000 JCX-1E 1E 2750V Single 60,000 40,000 JCX-2E 2E 2750V Single 60,000 40,000 JCX-3E 3E 2750V Single 60,000 40,000 JCX-5E 5E 2750V Single 60,000 40,000 JCX-7E 7E 2750V Single 60,000 40,000 JCX-10E 10E 2750V Single 60,000 40,000 JCX-15E 15E 2750V Single 80,000 50,000 JCX-20E 20E 2750V Single 80,000 50,000 JCX-25E 25E 2750V Single 80,000 50,000 JCX-30E 30E 2750V Single 80,000 50,000 JCX-40E 40E 2750V Single 80,000 50,000 JCX-50E 50E 2750V Single 80,000 50,000 JCX-65E 65E 2750V Single 80,000 50,000 JCX-80E 80E 2750V Single 80,000 50,000 JCX-100E 100E 2750V Single 80,000 40,000 JCX-125E 125E 2750V Single 80,000 50,000 JCX-150E 150E 2750V Single 80,000 50,000 JCX-200E 200E 2750V Single 80,000 50,000 JCX-225E 225E 2750V Single 80,000 50,000 JCX-250E/280X 250E/280X 2750V Double 80,000 50,000 JCX-300E/325X 300E/325X 2750V Double 80,000 50,000 JCX-350X 350X 2750V Double 80,000 50,000 JCX-400X 400X 2750V Double 80,000 50,000 JCX-450X 450X 2750V Double 80,000 50,000 5500V; E-Rated; Indoor/Enclosure JCY-⁄Ω™E ⁄Ω™E 5500V Single 60,000 40,000 JCY-1E 1E 5500V Single 60,000 40,000 JCY-2E 2E 5500V Single 60,000 40,000 JCY-3E 3E 5500V Single 60,000 40,000 JCY-5E 5E 5500V Single 60,000 40,000 JCY-7E 7E 5500V Single 60,000 40,000 JCY-10E 10E 5500V Single 60,000 40,000 JCY-15E 15E 5500V Single 60,000 40,000 JCY-20E 20E 5500V Single 60,000 40,000 JCY-25E 25E 5500V Single 60,000 40,000 Contact Bussmann for the latest product information on E-Rated Fuses for Transformer and feeder protection. Recommended Fuse Clips: 3 - 1A0065, 9078A67G04, A3354730 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 167 Bussmann® Medium Voltage Fuses and Fuse Links E-Rated Fuses for Trans. & Feeder Protection Specifications Buss Catalog No. Amperage Maximum Interrupting Capacity Dimensions Maximum Design Voltage Construction Amps. (Asym.) Amps. (Sym.) Length Diameter 17.81∑ (452.4mm) 3∑ (76.2mm) 12.88∑ (327.0mm) 2.1∑ (53.34mm) 17.88” (454.15mm) 3∑ (76.20mm) 28.81∑ (731.77mm) 4” (101.60mm) 15.51∑ (393.95mm) 2.1∑ (53.34mm) 17.88∑ (454.15mm) 3∑ (76.2mm) 15.88∑ (403.2mm) 3∑ (76.2mm) 5500V; E-Rated; Indoor/Enclosure JCU-10E 10E 5500V Single 80,000 50,000 JCU-15E 15E 5500V Single 80,000 50,000 JCU-20E 20E 5500V Single 80,000 50,000 JCU-25E 25E 5500V Single 80,000 50,000 JCU-30E 30E 5500V Single 100,000 63,000 JCU-40E 40E 5500V Single 100,000 63,000 JCU-50E 50E 5500V Single 100,000 63,000 JCU-65E 60E 5500V Single 100,000 63,000 JCU-80E 80E 5500V Single 100,000 63,000 JCU-100E 100E 5500V Single 100,000 63,000 JCU-125E 125E 5500V Single 100,000 63,000 JCU-150E 150E 5500V Single 100,000 63,000 JCU-175E 175E 5500V Single 100,000 63,000 JCU-200E 200E 5500V Single 100,000 63,000 JCU-250E 250E 5500V Single 100,000 63,000 JCU-300E 300E 5500V Double 100,000 63,000 JCU-350E 350E 5500V Double 100,000 63,000 JCU-400E 400E 5500V Double 100,000 63,000 JCU-450E 450E 5500V Double 100,000 63,000 JCU-600E 600E 5500V Double* 80,000 50,000 JCU-750E 750E 5500V Double* 80,000 50,000 8300V; E-Rated; Indoor/Enclosure JCZ-15E 15E 8300V Single 80,000 50,000 JCZ-20E 20E 8300V Single 80,000 50,000 JCZ-25E 25E 8300V Single 80,000 50,000 JCZ-30E 30E 8300V Single 80,000 50,000 JCZ-40E 40E 8300V Single 80,000 50,000 JCZ-50E 50E 8300V Single 80,000 50,000 JCZ-65E 65E 8300V Single 80,000 50,000 JCZ-80E 80E 8300V Single 80,000 50,000 JCZ-100E 100E 8300V Single 80,000 50,000 JCZ-125E 125E 8300V Single 80,000 50,000 JCZ-150E 150E 8300V Single 80,000 50,000 JCZ-200E 200E 8300V Double 80,000 50,000 JDZ-20E JDZ-25E JDZ-30E JDZ-40E JDZ-50E JDZ-65E JDZ-80E JDZ-100E JDZ-125E 20E 25E 30E 40E 50E 65E 80E 100E 125E 8300V 8300V 8300V 8300V 8300V 8300V 8300V 8300V 8300V Single Single Single Single Single Single Double Double Double 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 80,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 Recommended Fuse Clips: 3 - 1A0065, 9078A67G04, A3354730 General Notes: 1. All fuses are fitted with a striker pin which can be used for indication or tripping purposes. 2. The fuses are suitable for use either indoors or outdoors. 3. These fuses are interchangeable with corresponding fuses produced by most other leading North American manufacturers. Contact Bussmann for the latest product information on E-Rated Fuses for Transformer and feeder protection. *Bolt on mounting 168 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links Medium Voltage DIN Distribution Fuses DIN Dimension Fuses To Spec. DIN 43625 This product group covers current limiting fuses with dimensions to DIN 43625 and performance in compliance with IEC 282-1. Striker Characteristics The spring operated striker pin has a travel and energy output in compliance with the requirements of DIN 43625 and IEC 282-1. Current Ratings These are in accordance with the R10 and, in some cases, the R20 series of preferred numbers. Table of Ratings and Dimensions kV Dimensions Inches and mm Code Ref. Current Rating Diameter ≈ Length ADOSJ 6.3, 16, 20, 25, 31.5, 40, 2.00∑ ≈ 7.56∑ WDOSJ 50, 63, 80, 100, 125 51 ≈ 192 ____________________________________________________ ______________________________ WFOSJ 160, 200 3.00∑ ≈ 7.56∑ ADLSJ 6.3, 10, 16, 20, 25, 31.5, 2.00∑ ≈ 11.50∑ DIN Series IR RMS Symm 3.6/7.2 76 ≈ 192 ____________________________________________________________________________________________________ 3.6 50KA WDLSJ 40, 50, 63, 80, 100, 125 51 ≈ 292 ____________________________________________________ ______________________________ WFLSJ 160 10/12 WFLSJ 200 3.00∑ ≈ 11.50∑ WKLSJ 250 76 ≈ 292 WKLSJ 315, 400 _________________________________________________________________________________________________________________________ ______ SDLSJ 6.3, 10, 16, 20, 25, 31.5 2.00∑ ≈ 11.50∑ SDLSJ 40, 50, 63 51 ≈ 292 ____________________________________________________ ______________________________ 7.2 SFLSJ 80 10/12 SFLSJ 100 3.00∑ ≈ 11.50∑ SFLSJ 125 76 ≈ 292 SFLSJ 160 ____________________________________________________________________________________________________ WKMSJ 200 3.00∑ ≈ 17.41∑ 40KA 20/24 WKMSJ 250, 315, 355 76 ≈ 442 _________________________________________________________________________________________________________________________ ______ 12 SDLSJ 6.3, 10, 16, 20, 25 2.00∑ ≈ 11.50∑ SDLSJ 31.5, 40 51 ≈ 292 SDLSJ 50, 63 __________________________________________________________________________________ 10/12 50KA SFLSJ 63, 80 3.00∑ ≈ 11.50∑ SFLSJ 100 76 ≈ 292 SKLSJ 125, 160, 200 _________________________________________________________________________________________________________________________ ______ SDLSJ 6.3, 10, 16 2.00∑ ≈ 11.50∑ SDLSJ 20, 25 51 ≈ 292 SDLSJ 40 __________________________________________________________________________________ 17.5 10/12 SFLSJ 31.5 3.00∑ ≈ 11.50∑ SFLSJ 40, 50 76 ≈ 292 ____________________________________________________________________________________________________ SDMSJ 6.3, 10, 16 2.00∑ ≈ 17.41∑ SDMSJ 20, 25, 31.5 51 ≈ 442 SDMSJ 40 __________________________________________________________________________________ 35.5KA SFMSJ 50 3.00∑ ≈ 17.41∑ 20/24 SFMSJ 63, 80 76 ≈ 442 _________________________________________________________________ ______________________________ ________________ SFMSJ 100 3.00∑ ≈ 17.41∑ 25KA 15.5 SKMSJ 125 76 ≈ 442 _________________________________________________________________________________________________________________________ ______ 24 SDMSJ 6.3, 16 2.00∑ ≈ 17.41∑ SDMSJ 20, 25, 31.5 51 ≈ 442 SDMSJ 40 (24kv application only) __________________________________________________________________________________ 20/24 50KA SFMSJ 40, 50 3.00∑ ≈ 17.41∑ SFMSJ 63 76 ≈ 442 SFMSJ 71 (24kv application only) _________________________________________________________________________________________________________________________ ______ SDQSJ 36 6.3, 10, 16, 20, 25, 31.5 2.00∑ ≈ 21.16∑ 3.15 51 ≈ 442 ____________________________________________________ ______________________________ SFQSJ 31.5, 40, 50, 56 3.00∑ ≈ 21.16∑ 30/36 35.5KA 76 ≈ 537 _________________________________________________________________________________________________________________________ ______ Recommended Fuseclips for DIN Style Fuses: Bussmann Part Number 270303 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 169 Bussmann® Medium Voltage Fuses and Fuse Links Potential Transformer Fuses These are a range of fuses with low current rating, for use with voltage transformers or operating transformers to provide isolation of the associated system in the event of faults in the transformer circuit. “AB” & “AM” Series kV Code Reference 3.6 ABWNA Current Ratings 3.15, 6.3 Type Length AB 5.6∑ Diameter IR 1∑ 3.6 ABCNA 3.15, 6.3, 10 AB 7.69∑ 1∑ 5.5 ABWNA 0.5E, 1E, 2E, 3E, 5E AB 5.6∑ 1∑ 5.5 AMWNA 0.5E, 1.0E, 2.0E, 3.0E, 4.0E, 5.0E AM 5.6∑ 7.2 ABWNA 3.15, 6.3 AB 5.6∑ 50KA .81∑ 1∑ 7.2 ABCNA 3.15, 6.3 AB 7.69∑ 1∑ 12.0 ABCNA 3.15 AB 7.69∑ 1∑ 45KA 15.5 ABFNA 3.15 AB 10.00∑ 1∑ 32KA 17.5 ABGNA 3.15 AB 14.13∑ 1∑ 35KA 24.0 ABGNA 3.15 AB 14.13∑ 1∑ 25KA 36.0* ABGNA 3.15 AB 14.13∑ 1∑ 31.5KA Recommended fuse clip for 1∑ diameter fuses – A3354705. “CAV” Series Code Reference kV Current Ratings Length 3.6 CAV 2 5.5 CAV 15E 7.375∑ 5.5 CAVH 0.5E, 1E, 2E 7.375∑ 7.2 CAV 2, 10 8.66∑ 12 CAV 2 15.5 CAV 0.5E, 1E, 2E, 3E, 7E 12.87∑ 15.5 CAVH 0.5E, 1E, 2E 12.87∑ 17.5 CAV 2, 4, 6, 10 24 CAV 2, 3, 4 13.39∑ 36 CAV 2, 4 17.32∑ 36 CAVH 2 17.32∑ 38 CAV 4E 17.32∑ 38 CAVH 0.5E, 1E, 2E 17.32∑ Diameter IR 1.63∑ 40KA 8.66∑ 8.66∑ 8.66∑ *For clean indoor applications only. Type CAVH are fitted with a striker pin for indication. Catalog Code: kV Code Reference Current Rating Recommended Fuse Clips: 1 dia. - A3354705 1.63” dia. - 1A0835 .81 dia. - 1A1837 Contact Bussmann for complete specifications on Potential Transformer Fuses 170 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links Medium Voltage, Fast Acting Fuses Test Specifications Catalog Number HVA, HVB, HVJ, HVL, HVR, HVT, HVU, HVW & HVX Load Opening Time HVA HVB HVJ HVL 110% 135% 4 Hours (min.) 1 Hour (max.) HVR HVT HVU HVW HVX 100% 150% 4 Hours (min.) 1 Hour (max.) Non-Time Delay Ampere Ratings: Voltage Rating: 1000 to 10,000V HVA (1000 Volts) (Max. S.C. 20KW dc, 30KVA ac) Length Amps ⁄Ω¡§ ⁄Ω• ⁄Ω¢ ⁄Ω¡º ¤Ω¡º ‹Ω¡º ‹Ω• ⁄Ω™ ‹Ω¢ 1 1⁄Ω™ 2 3 4 6 10 Dia. In. mm 0.41∑ 3∑ 76.1 *Wt./100 Lbs. Kg 2 0.91 4528, 4529, 4530 & 2960 Fuseblocks Voltage Rating: 1000 to 10,000V HVB (2500V) (Max. S.C. 20KW dc, 30KVA ac) ⁄Ω™ ‹Ω¢ 1 1⁄Ω™ 2 3 0.41∑ 4.5∑ 114.2 3 1.36 HVJ (5000V) (Max. S.C. 20KW dc, 30KVA ac) ⁄Ω¡§ ⁄Ω• ⁄Ω¢ ⁄Ω™ ‹Ω¢ 1 1⁄Ω™ 2 4 6 10 — HVA HVR 0.81∑ 5∑ 126.9 9 4.08 HVJ 1 1⁄Ω™ 2 3 0.81∑ 10∑ 253.8 HVU 15 6.80 3 4 5 0.41∑ 3∑ 76.1 HVL HVX Block Cat. No. 4528 4529 4530 2960 Use #8 screws on blocks 4528 and 4529. Use #10 screws on blocks 4530 and 2960. HVR (1000V) (Max. S.C. kVA-500 ac only) ⁄Ω™ 1 2 HVB HVT HVL (10,000V) (Max. S.C. 20KW dc, 30KVA ac) ⁄Ω¡§ ⁄Ω• ⁄Ω¢ ⁄Ω™ For Fuse Sym. 3 1.36 2 0.91 4 1.81 19 8.62 36 16.33 HVW (1200V) (Max. S.C. kVA-12,000 ac only) — 1 2 — 3 4 5 8 0.41∑ 2.25∑ 57.1 HVT (2500V) (Max. S.C. kVA-1250 ac only) ⁄Ω™ 1 2 3 5 — 0.41∑ 4.5∑ 114.2 HVU (5000V) (Max. S.C. kVA-2500 ac only) ⁄Ω™ 1 2 3 4 5 0.81∑ 5∑ 126.9 HVX (10,000V) (Max. S.C. kVA-5,000 ac only) ⁄Ω™ 1 3 5 0.41∑ 10.0∑ 253.8 *Shipping. Carton quantity: 10. Data Sheet: 6003 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 171 Bussmann® Medium Voltage Fuses and Fuse Links Medium Voltage — BS2692-1 Fuses General Guide to the Selection of HV Fuse Links, used in oilfield switchgear. For use in the Primary Circuit of Three Phase 50 Hz Transformers Transformer Primary Voltage 11kV Transformer kVA 200 250 300/315 400 500 630 750/800 1000 1250 1600 3.3kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV 3.6kV OEFMA 63 OEFMA 80 OEFMA 100 OEFMA 125 OEFMA 160 OEFMA 200 OLGMA 250 OLGMA 250* — — 6.6kV ESI 12-8 Ref. 12kV OEFMA 31.5 12kV OEFMA 40 12kV OEFMA 50 12kV OEFMA 63 12kV OHFMA 71 7.2kV OEFMA 100 7.2kV OHGMA 125 7.2kV OHGMA 140 7.2kV OHGMA 160* — 01 — 02 — 03 — 04 05 — — Fuse Rating 12kV 12kV 12kV 12kV 12kV 12kV 12kV 12kV 12kV 12kV OEFMA 25 OEFMA 25 OEFMA31.5 OEFMA 40 OEFMA 50 OEFMA 63 OHFMA 80 OHGMA 90** OHGMA 100 OLGMA 125* 13.8kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV 15.5kV OEFMA 16 OEFMA 20 OEFMA 25 OEFMA 31.5 OEFMA 40 OEFMA 50 OEFMA 63 OHGMA 71 OHGMA 90 OLGMA 100* This selection table has been based upon the following criteria: 1. Withstand against magnetizing inrush current taken as 12 times full-load current for 0.1 second. 2. Withstand against 150% permissible overload current. Recommendations marked with asterisks have the following significance:*Limited to permissible overloads of 130%. **Permits use of a 12kV OHFMA 80A fuse with a 100kVA transformer where permissible overload does not exceed 130%. 3. For 6.6kV systems, 12kV fuse links are recommended where possible in the interests of standardization. 4. Wherever possible, 10 inch long FO1 fuse links are offered rather than equivalent 14 inch FO2 types. 5. The above recommendations are not generally applicable to transformers feeding motor circuits with starting currents in excess of the transformer full load current. In this event, please consult Bussmann. Code References in Table Letter Reference Explanation 1st Type O = Oiltight 2nd Diameter E, H, L = 63.5 mm 3rd Length F = 254 mm, G = 359 mm 4th Striker M = As specified in BS 2692 table 11. 5th Tags A = none, i.e. plain caps Table of Preferred Ratings Rated kV Code Reference Dimensional Ref. BS 2692 Current Ratings (amps) Breaking Capacity (kA) 3.6 OEFMA FO1 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200 50 3.6 3.6 OEGMA OLGMA FO2 FO2 100, 125, 160, 200 250 50 50 7.2 7.2 OEFMA OHGMA FO1 FO2 80, 100, 112 125, 140, 160 45 45 12.0 12.0 12.0 12.0 OEFMA OHFMA OHGMA OLGMA FO1 FO1 FO2 FO2 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 71, 80 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 71, 80, 90, 100 125 40 40 40 40 15.5 15.5 15.5 OEFMA OHGMA OLGMA FO1 FO2 FO2 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 71, 80, 90 100 40 40 40 17.5 OHGMA FO2 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 80 35 24.0 OEGMA FO2 6.3, 10, 16, 20, 25, 31.5, 40, 50 25 Contact Bussmann for complete specifications on Medium Voltage Fuses 172 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Medium Voltage Fuses and Fuse Links Medium Voltage Fuse Links High-Surge Type H Fuse Links High-surge, Type H fuse links are manufactured in ratings of 1, 2, 3, 5, and 8A. They have been developed principally for primary fusing of small-sized transformers. Type H links are manufactured in the universal buttonhead design. Type N Fuse Links Type N fuse links conform to previous NEMA standards and have been superseded by Type K and T links. Type N fuse links are manufactured in the universal button design in ratings of 5 through 200A for use in NEMA standard dimensioned cutouts rated through 27 kv. Catalog Data-EEI-NEMA and High-Surge Universal Tin Element Fuse Links for Cutouts. Rated to 27kV EEI-NEMA Type K and T Fuse Links These fuse links afford effective overcurrent protection to systems and equipment. In addition to apparatus protection, they can be coordinated with other overcurrent protective devices for sectionalizing in order to isolate feeder branches. Catalog Data-EEI-NEMA and High-Surge Universal Tin Element Fuse Links for Cutouts. Rated to 27kV Link Amps Type H (High Surge) EEI-Nema Type K (Fast) EEI-Nema Type T (Slow) Carton Data Weight Qty. Lbs. Kg's. Non-Removable Button-Head For Standard Open Or Enclosed Cutouts 1 FL11H1 FL11K1 FL11T1 _______________________________________________ 2 FL11H2 FL11K2 FL11T2 _______________________________________________ 25 2 0.91 3 FL11H3 FL11K3 FL11T3 _______________________________________________ 5 FL11H5 FL11K5 FL11T5 ____________________________________________________________________ __ 6 — FL11K6 FL11T6 _______________________________________________ 8 FL11H8 FL11K8 FL11T8 _______________________________________________ 10 — FL11K10 FL11T10 _______________________________________________ 12 — FL11K12 FL11T12 _______________________________________________ 25 2 0.91 15 — FL11K15 FL11T15 _______________________________________________ 20 — FL11K20 FL11T20 _______________________________________________ 25 — FL11K25 FL11T25 ____________________________________________________________________ __ 30 — FL11K30 FL11T30 _______________________________________________ Link Amps Type H (High Surge) EEI-Nema Type K (Fast) Carton Data EEI-Nema Type T (Slow) Weight Qty. Lbs. Kg's. Removable Button-Head For Cutouts Requiring Removable-Button Links* 1 — FL3K1 FL3T1 _______________________________________________ 2 — FL3K2 FL3T2 _______________________________________________ 3 — FL3K3 FL3T3 _______________________________________________ 5 — FL3K5 FL3T5 _______________________________________________ 6 — FL3K6 FL3T6 _______________________________________________ 8 — FL3K8 FL3T8 _______________________________________________ 25 1.81 0.82 10 — FL3K10 FL3T10 _______________________________________________ 12 — FL3K12 FL3T12 _______________________________________________ 15 — FL3K15 FL3T15 _______________________________________________ 20 — FL3K20 FL3T20 _______________________________________________ 25 — FL3K25 FL3T25 ____________________________________________________________________ __ 30 — FL3K30 FL3T30 _______________________________________________ 40 — FL3K40 FL3T40 25 3.44 1.56 _______________________________________________ 50 — FL3K50 FL3T50 ____________________________________________________________________ __ 65 — FL3K65 FL3T65 _______________________________________________ 80 — FL3K80 FL3T80 15 3.63 1.65 _______________________________________________ 100 — FL3K100 FL3T100 ____________________________________________________________________ __ 140 — FL3K140 FL3T140 10 7.63 3.46 _______________________________________________ 200 — FL3K200 FL3T200 ____________________________________________________________________ __ 40 — FL11K40 FL11T40 25 4 1.82 _______________________________________________ 50 — FL11K50 FL11T50 ______________________________________________________________________ *Adapter-type removable-button links with ferrule adapter to convert to double-leader links are available in K and T types. Order by description. 65 — FL11K65 FL11T65 _______________________________________________ 80 — FL11K80 FL11T80 _______________________________________________ Catalog Data—EEI-NEMA Type K Universal Silver-Element Fuse Links for Cutouts Rated through 27kV 15 5 2.27 _______________ 5.5 2.49 _______________ 100 — FL11K100 FL11T100 6 2.72__ ____________________________________________________________________ 140 — FL11K140 FL11T140 7 3.17 _______________________________________________ 10 _______________ 200 — FL11K200 FL11T200 10 4.53 ______________________________________________________________________ Link Rating Amps Carton Data EEI-Nema Type K Weight Qty. Lbs. Kg's. Non-Removable Button-Head For Standard Open Or Enclosed Cutouts 8 FL12K8 ___________________________ _ 10 FL12K10 ___________________________ _ 12 FL12K12 ___________________________ _ 15 FL12K15 ___________________________ _ 25 2 0.91 25 FL12K25 ____________________________________________________________________ __ 50 FL12K50 25 3 1.34 ____________________________________________________________________ __ For complete specification data, call Bussmann Information Fax ~ 636.527.1450 173 Page 174 BLANK (Do NOT Print) Bussmann® Telpower® DC Power Protection Systems Telpower® Compact Fused Disconnect Switch TPC & TPCDS TPC & TPCDS TPCDS - Telpower® Compact Fused Disconnect Switch TPC - Telpower® Compact Fuse - Current Limiting Ampere Ratings: 3-125A Available Ratings: 3, 4, 5, 6, 7, 8, 10, 12, 15, 20, 25, 30, 40, 50, 60, 75, 90, 100, 125A Voltage Rating: 80Vdc Interrupting Rating: 100,000A Agency Information: UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Recognized to U.S. and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412. General Information: • Fusible solution for replacement of existing DC Telecom circuit breakers. • Compact size fused disconnect switch. • AmpColor ID™ System for easy fuse replacement. • Available in two disconnect switch profiles in addition to a variety of terminal styles. • Local and remote open fuse indication. Local alarm indication provided by LED on TPC fuse. • Remote alarm terminal available in three positions common to DC circuit protection devices. • Recommended .75 inch center-to-center product spacing. • Current-limiting capability • Complete system coordination capability. • Highest interrupting rating (100,000A) available for DC circuit protection of this footprint. • No venting of arc or molten metals and gases during opening. • Fuse material: Black thermoplastic, UL rated 94 V-O, 170° C RTI. • Housing material: Black thermoplastic, UL rated 94 V-O, 120° C RTI. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering for more information. Look for Telpower® BLUE™ fuses exclusively from Cooper Bussmann. Catalog Number TPC-3 TPC-4 TPC-5 TPC-6 TPC-7 TPC-8 TPC-10 TPC-12 TPC-15 TPC-20 TPC-25 TPC-30 TPC-40 TPC-50 TPC-60 TPC-75 TPC-90 TPC-100 TPC-125 TPCDS-BBE-1 TPCDS-BBE-2 TPCDS-BBE-3 TPCDS-BBM-1 TPCDS-BBM-2 TPCDS-BBM-3 TPCDS-BSE-1 TPCDS-BSE-2 TPCDS-BSE-3 TPCDS-BSM-1 TPCDS-BSM-2 TPCDS-BSM-3 TPCDS-SSE-1 TPCDS-SSE-2 TPCDS-SSE-3 TPCDS-SSM-1 TPCDS-SSM-2 TPCDS-SSM-3 TPCDS-D-BC1* TPCDS-D-BC2* TPCDS-D-CC1* TPCDS-D-SEC1* TPCDS-D-SEC2* TPCDS-D-SMC1* TPCDS-D-SMC2* Description Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Fuse Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Compact Disconnect Ampere Rating 3A 4A 5A 6A 7A 8A 10A 12A 15A 20A 25A 30A 40A 50A 60A 75A 90A 100A 125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A 3-125A *Not investigated to Canadian Requirements. Data Sheet: 5023 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 175 Bussmann® Telpower® DC Power Protection Systems Telpower® Miniature Fused Disconnect Switch TPM & TPMDS TPM & TPMDS General Information: TPMDS - Telpower® Miniature Fused Disconnect Switch TPM - Telpower® Miniature Fuse - Current Limiting Ampere Ratings: 3-30A Voltage Rating: 80Vdc Interrupting Rating: 20,000A Agency Information: UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Recognized to U.S. and Canadian requirements under the component recognition program of Underwriters Laboratories Inc. Files E219046 and E56412. • Smallest and most versatile fused disconnect switch available. • Small size allows for assembly into 1 U (1.75 inch / 44.5 mm) panel. • AmpColor ID™ System for easy fuse replacement. • Switch design provides for easy panel mounting by single captive 4-40 (M3) nut and panel notch integral to switch footprint. • Local and remote open fuse indication. Local alarm indication provided by LED on TPM fuse. • Current-limiting capability • Complete system coordination capability • Load connection: 1/4 inch quick-connect or bolted connection with 10-32 (M5) captive nut. • Line connection: 1/4 inch quick-connect or screw connection with clearance hole for #10 (M5) bolt. • Maximum alarm circuit current: 20 mA • Materials: Fuse housing - black thermoplastic, UL 94 V-0, 170ºC RTI Switch housing - black thermoplastic, UL 94 V-0, 140ºC RTI Catalog Number TPM-3 TPM-4 TPM-5 TPM-6 TPM-7 TPM-8 TPM-10 TPM-12 TPM-15 TPM-20 TPM-25 TPM-30 TPMDS-E TPMDS-M Description Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Fuse Miniature Disconnect, English Miniature Disconnect, Metric Ampere Rating 3A 4A 5A 6A 7A 8A 10A 12A 15A 20A 25A 30A 3-30A 3-30A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering for more information. TPM Alarm Schematic NOTES: 1. The resistance, R, must be provided by the end-user to limit the alarm output current to a maximum of 20 mA. The value, R, should be calculated using the system voltage value. If remote alarm functionality is not required, the END-USER CIRCUITRY must still be supplied to provide a resistive path to the return for the local alarm to properly function. 2. The fuse is polarized to maintain proper orientation with the switch housing. The line and load terminals are identified on the switch housing. • Look for Telpower® BLUE™ fuses exclusively from Cooper Bussmann. Data Sheet: 5022 176 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Telecommunications Protection Fused Disconnect Switch TP15914 4 Pole Disconnect Switch and TPA Series Fuses Ampere Rating: 50A per pole Voltage Rating: 145Vdc Agency Information: UL recognized as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier. UL recognized as a component for telecommunication power distribution equipment (UL category QPQYZ). UL recognized fuses for branch circuit protection. CSA component acceptance for the system. Material: UL rated 94V-0, 140°C rated Fuse Fuse Type Current Voltage Interrupting TPA 3, 5, 10, 15, 20, 25, 30, 40, 50 170Vdc 100 kA • Front access load and line connection standard—double lug load connections 8 AWG wire. • Recognized branch circuit protection device. • Modular design—4 poles per module up to four modules banked together. • Ease of installation—Connection directly to bus bar. • Reduces external wiring—per pole. • LED alarm signaling (LED current 30mA max.). • Blown fuse indication. • Alarm test probe point, to allow on-site checking of alarm circuitry. • Snap into alarm bus. • Bi-polar LED provides capability for both –48V DC and +24V DC applications. • Fuse presence indication. • Fuse orientation rejection feature. • Totally enclosed module. • Spare fuseholders: Part No. 5TPH and TPSFH-A • Remote alarm. • Contact Bussmann for options on standard module (Hardware, Color, Front line connection, Mounting bezel). CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. TPA-B 20, 25 65Vdc 20 kA UL Recognized, Guide JFHR2, File E56412 CSA Certified, Class 1422-30, File 53787 Dimensional Data MM Inches 76.07 3.0 TOP Data Sheet: 5011 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 177 Telpower® DC Power Protection Systems Bussmann® Fused Disconnect Switch & TPA Fuses TP15900-4 4-Pole Disconnect Switch For use with Telpower fuses Type TPA & TPA-B. Electrical Ratings: 40A per pole at 145Vdc 50A per pole at 80Vdc Agency Information: UL Recognized as a disconnect switch for interruption of load current by means of withdrawing the fuse carrier. UL Recognized as a component for telecommunication power distribution equipment (UL category QPQY2). UL Recognized fuses for branch circuit protection. CSA Component Acceptance for the system. General Information: • Ease of installation - connection directly to bus bar. • Reduces external wiring per pole. • LED alarm signaling (LED current 30mA max.). • Local and remote open-fuse indication. • Alarm test probe point, to allow on-site checking of alarm circuitry. • Fuse presence indication. • Fuse orientation rejection feature. • Rear accessibility for line and load terminations. Material: UL rated 94V-0, 140°C rated ® Catalog Numbers TP15900-4 TP15900-41 DC Power Distribution Indicating Fuses Ampere Rating: TPA: 3, 5, 10, 15, 20, 25, 30, 40, 50 TPA-B: 20, 25, 30 Voltage Rating: TPA, 170 Vdc; TPA-B, 65 Vdc Interrupting Rating: TPA, 100 kA; TPA-B, 20 kA Agency Information: UL Recognized, Guide JFHR2, File E56412 CSA Certified, Class 1422-30, File 53787 Construction: • Silver-plated brass ferrules and indicator pin on TPA 3-15 and TPA-B. Tin-plated brass on TPA 20-50 on indicator end. • Glass melamine tube. • Spare fuseholders: 5 position holder; 5TPH; 6 position holder; TPSFH-AS Dimensional Data mm inches Split Alarm, Split Line CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 5001 TPA & TPA-B CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 5012 Dimensional Data 178 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Telpower® DC Power Protection Systems Bussmann® Fused Disconnect Switch TPS Ampere Ratings: 1 to 70A. Voltage Rating: 170Vdc Agency Information: UL Recognized, Guide JFHR2, File E56412 Catalog Numbers 15800 Fused Disconnect Switch Ampere Ratings: 3 to 70A. Voltage Rating: 60Vdc Agency Information: UL Recognized, Guide QPQY2, File E97649 UL Withstand Rating: 100,000A, Catalog Numbers 15800-R-200 Rear Access Panel Mounting 15800-F-200 Front Access Panel Mounting • For use with the following fuses only: Main: Telpower® TPS 3 to 70 Amp Alarm: Bussmann GMT-A only (page 183). Recommend GMT-X Cover (page 183). • Alarm output with wire wrap terminal or connection to .063” thick common alarm bus. • Thermoplastic housing material U.L. rated 94V-0, 150°C. • Spare alarm and power fuse compartment. • Mounting hardware included. • Spare fuseholders: for TPS fuses (TPSFH-AS); for GMT fuses (TPSFH-T), see page 196. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data 15800-R-200 TPS-1 TPS-1L TPS-2 TPS-2L TPS-3 TPS-3L TPS-5 TPS-5L TPS-6 TPS-6L TPS-10 TPS-10L TPS-15 TPS-15L TPS-20 TPS-20L TPS-25 TPS-25L TPS-30 TPS-30L TPS-35 TPS-35L TPS-40 TPS-40L TPS-40V TPS-50 TPS-50L TPS-50V TPS-60 TPS-60L TPS-70 TPS-70L TPS-70LB — — — Dimensional Data • TELPOWER fuse line is the first to be specifically designed to meet the unique needs of DC Power Distribution Systems. • The UL Recognized ratings of 170Vdc and 100,000A interrupting rating along with the fuse’s current limiting capability make this fuse ideal for cable protection on exist ing DC Distribution Systems. • A unique BLUE label is used on all TELPOWER fuses to designate their DC capability. • Circuit board applications available. • Silver-plated brass ferrules. • Glass melamine tube. • For use with Bussmann Fused Disconnect Switch 15800. • Spare Fuseholder: TPSFH-AS, see page 198. • Printed circuit board variations available. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 5002 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 5009 179 Telpower® DC Power Protection Systems Fused Disconnect Switch Bussmann® TP158HC TP158HC Fused Disconnect Switch For use with Telpower® Fuses Type TPL-B. Ampere Ratings: 70-250A Voltage Rating: 80Vdc UL Withstand Rating: 100,000A Agency Information: UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse pullout. Guide QPQY2, File E97649. Catalog Numbers: TP158HC: Rear Access, Panel Mounting, English TP158HC: Rear Access, Panel Mounting, Metric General Information: • High amp version of Bussmann 15800 series Fused Disconnect Switch. • Similar profile, mounting method, and backplane configuration as 15800 Series. The TP158HC can be installed into existing 15800 Series panels using the space of two 15800 disconnects. • Innovative new fuse pullout design eliminates need for tools to replace the Telpower® type TPL-B fuse. • For use with the following fuses only: Main: Telpower® TPL-B 70-250 Amperes. Alarm: Bussmann GMT-A only. • Alarm output with wire wrap terminal or connection to .063” thick common alarm bus. • Hardware included: Load: washer, split lockwasher, and 5/16 _ 18 nut. Easy Fuse Replacement • Thermoplastic housing material UL rated 94V-0, 150°C. • Spare fuseholders: for TPL-B fuses (TPSFH-LB), see page 14; for GMT fuses (TPSFH-T), see page 14. • Application Note: The line connection uses a 1/4-20 bolt (metric – M6X1) that threads into the line terminal. The line terminal is designed with a float of ±.02 in. (± .50mm) to allow for variation in the distance between the TP158HC mounting flange and the line bus bar (see dimensional data). Equipment should be designed to eliminate any relative movement between the TP158HC mounting flange and the line bus bar. • Application Note: The alarm circuit is not intended for precharging of capacitive circuits. Alarm circuit current 1A maximum. Data Sheet: 5021 180 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Telpower® DC Power Protection Systems Fused Disconnect Switches 15100 15200 Fused Disconnect System For use with Telpower® Fuses Type TPL. Ampere Ratings: 70-800A. Voltage Rating: 60Vdc UL Withstand Rating: 100,000A Agency Information: UL Recognized, Guide QPQY2, File E97649 Ampere Ratings: 70-800A Voltage Rating: 60Vdc UL Withstand Rating: 100,000A Agency Information: UL Recognized, Guide QPQY2, File E97649 Catalog Numbers 15100-401 15100-601 Fused Disconnect System For use with Telpower® Fuses Type TPL. For Use With TPL series fuses For Use With TPL series fuses 70-400A 300-800A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data 15100-401 Catalog Numbers 15200-602 For Use With TPL 70 to 800A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data 15200-602 6.75" (171.45mm) 3" 1" (76.2mm) (25.4mm) 3" 4" (76.2mm) (101.6mm) 5.86" (149.22mm) 8.69" (220.66mm) 0.27" (6.75mm) Dia. Hole with 0.5" (12.7mm) Dia. x 0.16" (3.97mm) Deep C'bore (4 Holes) 5.75" (146.05mm) 2" 0.88" (50.8mm) (22.22mm) #14 Thd. 1.88" (47.62mm) 7.25" (184.15mm) 3.63" (92.07mm) 0.31" (7.93mm) #18 Tap x 0.5" (12.7mm) Deep (4 Holes) 2.75" (69.85mm) 7.13" (181.10mm) 6.75" 5" (127.0mm) (171.45mm) 0.5" 11" (12.7mm) (279.4mm) 1.31" (33.33mm) 12" 2.63" (304.8mm) (66.67mm) 5.25" (133.35mm) Data Sheet: 5003 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 5004 181 Telpower® DC Power Protection Systems Bussmann® Telpower® High Current Switch TPHCS-Dimensional Data mm (in) Ø 7.62 (0.300) Typ. 4 ▲ ▲ 41.02 (1.615) ▲ 66.4 (2.62) ▲ 22.2 (0.88) ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ 122.43 (4.820) ▲ 25.9 (1.02) 8.8 (0.34) ▲ ▲ 12.7 (0.50) 17.3 (0.68) ▲ ▲ ▲ ▲ ▲ 100.5 REF (3.96) 74.6 (2.94) ▲ ▲ ▲ Threaded Insert, 4 Places M8x1.25 (-M Series) 5/16-18 (-E Series) Recommended Torque 15N • m (11 Ft-lb) ▲ NOTES: 1. TPHCS250 and TPHCS800 pullouts and bases 24.8 REF are the same with (0.98) exception to the ▲ type of fuse, TPL-B, TPL-C or TPH the ▲ pullout will carry. 2. Plastic rated UL94 16.76 V-0, 140°C RTI. (0.660) ▲ 105.2 (4.14) 139.7 (5.50) Tin Plated Copper Terminals Catalog Numbers-Switches (Pullout and Base) TPHCS250-M High Current Switch, Metric TPHCS250-E High Current Switch, English TPHCS250-ML High Current Switch, Metric, LED TPHCS250-EL High Current Switch, English, LED TPHCS250-MAV High Current Switch, Metric, Alarm TPHCS250-EAV High Current Switch, English, Alarm TPHCS800-M High Current Switch, Metric TPHCS800-E High Current Switch, Englis TPHCS800-ML High Current Switch, Metric, LED TPHCS800-EL High Current Switch, English, LED TPHCS800-MAV High Current Switch, Metric, Alarm TPHCS800-EAV High Current Switch, English, Alarm Series Fuse TPL-B TPL-B TPL-B TPL-B TPL-B TPL-B TPL-C or TPH TPL-C or TPH TPL-C or TPH TPL-C or TPH TPL-C or TPH TPL-C or TPH Ampere Rating 70 to 250A 70 to 250A 70 to 25 A 70 to 250A 70 to 250A 70 to 25 A 300 to 800A 300 to 800A 300 to 800A 300 to 800A 300 to 800A 300 to 800A Catalog Numbers – Components TPHCS250-P Pullout only – 250 A TPHCS800-P Pullout only – 800 A TPHCS-B-M Base only, Metric TPHCS-B-E Base only, English TPHCS-B-ML Base only, Metric, LED TPHCS-B-EL Base only, English, LED TPHCS-B-MAV Base only, Metric, Alarm TPHCS-B-EAV Base only, English, Alarm Series Fuse Ampere Rating TPL-B 70 to 250A TPL-C or TPH 300 to 800A — 800A Max. — 800A Max. — 800A Max. — 800A Max. — 800A Max. — 800A Max. ▲ ▲ ▲ ▲ ▲ 39.2 REF (1.54) 61.47 (2.420) ▲ General Information: • Innovative new design eliminates need for tools to replace the Telpower® type TPL-B, TPL-C or TPH fuse. • Easy to install–captive fasteners allow for direct busbar mounting (bolts not included). • Optional new electronic alarm provides both local and remote open-fuse indications. —Bipolar alarm designed for both Central Office and Radio applications. —Local LED alarm indication for ease-of-viewing. —Standard ⁄Ω¢∑ male quick-connect terminal for effortless remote alarm connection (Maximum remote alarm current: 20mA). —Eliminates need for parallel indicating fuses. • Fuse presence window allows for easy viewing of installed fuse ampere rating. • Compact design for today’s high power, high-density cabinets. • Available as complete switch or pullout and base may be purchased separately. See table for part number format ▲ Telpower® High Current Switch For use with Telpower® Fuses Type TPL-B, TPL-C and TPH. Ampere Ratings: 70 to 800A Voltage Rating: 80Vdc UL Withstand Rating: 100,000A Agency Information: UL Recognized (investigated to UL 1801) as a disconnect switch for the interruption of load current by means of withdrawing the fuse carrier. UL Recognized to meet the requirements for Canadian Standards. ▲ TPHCS 13.2 (0.52) ▲ TPHCS800-MAV (shown) Data Sheet: 5020 182 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Telpower® DC Power Protection Systems Bussmann® Telpower® Fuses, 70-600 Amps, 170 Volts DC Dimensional Data 2.66" (67.5mm) 2.19" (55.6mm) 1.91" (48.4mm) 1.0" 1.16" (25.4mm) (29.4mm) BUSS .75" (19.1mm) TPL–BL .33" .19" (8.3mm) (4.8mm) TPL-BA, TPL-BD, TPL-BF, TPL-BH, TPL-BK, AND TPL-BL TPL 3.50" (88.9mm) 2.44" DC Power Distribution Fuses Ampere Ratings: 70-800A Voltage Rating: 170Vdc Current Limiting Interrupting Rating: 100,000A Construction: Silver-Plated Terminals Agency Information: UL Recognized Guide JFHR2, File E56412 Bellcore (61.9mm) 1.50" 1.25" (38.1mm) (31.8mm) BUSS 1.00" (25.4mm) TPL–CZ .41" (10.3mm) .25" (6.4mm) TPL-CN, TPL-CR, TPL-CV, AND TPL-CZ CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Ordering Information: TPL Telpower® (170Vdc) Catalog Number Ampere Rating Weight* Carton Qty. Lbs. Kg. TPL-BA 70 5 .93 .42 TPL-BB 80 5 .93 .42 TPL-BC 90 5 .93 .42 TPL-BD 100 5 .93 .42 TPL-BE 125 5 .93 .42 TPL-BF 150 5 .93 .42 TPL-BG 175 5 .93 .42 TPL-BH 200 5 .93 .42 TPL-BK 225 5 .93 .42 TPL-BL 250 5 .93 .42 TPL-CN 300 1 .49 .22 TPL-CO 350 1 .49 .22 TPL-CR 400 1 .49 .22 TPL-CU 450 1 .49 .22 TPL-CV 500 1 .49 .22 TPL-CZ 600 1 .49 .22 TPL-CZH 800 1 .49 .22 • • • • • Designed for DC power distribution systems. Recognized branch circuit protection. Current-limiting capability. Complete system coordination capability. Energy savings with low watts loss, low operating temperatures, and minimum I2t levels. • Use with Telpower 15100, 15200, TP158HC and TPHCS disconnect systems. • For replacement of Bussmann’s UBO fuses a TPL-TA adaptor kit is necessary. • Spare fuseholders: TPSFH-LB (for TPL-B fuses) TPSFH-LC (for TPL-C fuses) *Weight per carton. Data Sheet: 5005 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 183 Telpower® DC Power Protection Systems Bussmann® Telpower® Fuses, 1-600 Amps, 170 Volts DC 0.56" (14.3mm) 2" (50.8mm) 1A to 30A 0.81" (20.6mm) 3" (76.2mm) 35A to 60A 5.88" (149.2mm) 1.00" TPN (25.4mm) Current Limiting DC Power Distribution Fuses Ampere Ratings: 1-600A Voltage Rating: 170Vdc Interrupting Rating: 100,000A Construction: Silver-Plated Terminals Agency Information: UL Recognized, Guide JFHR2, File E56412 70A to 100A 7.13" (181.0mm) 1.50" (38.1mm) 110A to 200A 8.63" (219.1mm) 2.00" (50.8mm) 225A to 400A 10.38" (263.5mm) Catalog Numbers TPN-1 TPN-45 TPN-200 TPN-3 TPN-50 TPN-225 TPN-5 TPN-60 TPN-250 TPN-6 TPN-70 TPN-300 TPN-10 TPN-80 TPN-350 TPN-15 TPN-90 TPN-400 TPN-20 TPN-100 TPN-450 TPN-25 TPN-110 TPN-500 TPN-30 TPN-125 TPN-600 TPN-35 TPN-150 TPN-40 TPN-175 Carton Qty. 450A to 600A Recommended Class R Fuseblocks Amps 1 to 30 35 to 60 Carton Quantity and Weight TPN Telpower (170Vdc) Catalog Number 2.50" (63.5mm) 70 to 100 Weight* Lbs. Kg. 110 to 200 Poles Catalog Number 1 R25030-1CR 2 R25030-2CR 3 R25030-3CR 1 R25060-1CR 2 R25060-2CR 3 R25060-3CR 1 R25100-1CR 2 R25100-2CR 3 R25100-3CR 1 R25200-1CR 3 R25200-3CR 1-30 10 0.45 0.204 35-60 10 1.82 0.824 225 to 400 1 R25400-1CR 70-100 5 1.85 0.838 450 to 600 1 R25600-1CR 110-200 1 1.05 0.476 225-400 1 2.38 1.078 450-600 1 3.50 1.587 *Weight per carton. • Designed for DC power distribution systems. • The TPN series of fuses are dimensionally similar to Class R fuses. • Recognized branch circuit protection. • Current-limiting capability. • Complete system coordination capability. • Energy savings with low watts loss, low operating temperatures, and minimum I2t levels. • Spare fuseholders: TPSFH-N30 (for TPN 1-30) TPSFH-N60 (for TPN 35-60) Data Sheet: 5006 184 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Telpower® DC Power Protection Systems Indicating Fuse & Holder 70 Series 15087 Fuseholder Indicating Type Fuse Voltage Rating: 125Vac; 300Vdc Agency Information: UL Recognized, Guide JDYX2, File E19180 Bellcore For 70 Series Fuses Ampere Ratings: 12A Voltage Rating: 300Vdc Agency Information: UL Recognized, Guide IZLT2, File E14853 Construction: Body: Thermoplastic, UL 94VO flammability rating Terminals: Copper alloy, tin plating Screws: 3-24 ≈ ‹Ω•∑ steel, zinc plated 70 Series Telpower (125Vac, 300Vdc) Catalog Number Ampere Rating 70P-⁄Ω¡º A* 70R-⁄fiΩ¡ººA* 70E-⁄°Ω¡ºº A* 70X-¤Ω¡º A 70F-⁄Ω¢ A* 70K-⁄Ω¢ A* 70G-⁄Ω™ A* 70H-‹Ω¢ A* 70I-1A 70A-1-⁄Ω£ A* 70B-2A* 70C-3A* 70J-3⁄Ω™ A 70D-5A* 70L-6A 70M-8A 70N-10A GKB-10A 72A Plastic Case 72B Blister Pack ⁄Ω¡º ⁄fiΩ¡ºº ⁄°Ω¡ºº ¤Ω¡º ⁄Ω¢ ⁄Ω¢ ⁄Ω™ ‹Ω¢ 1 1⁄Ω£ 2 3 3⁄Ω™ 5 6 8 10 10 Voltage Rating AC DC Color Code Lucent Comcode Ref. No. Code/ List No. Gray/Wh Red/Wh Yellow Black Violet Violet/Wh Red Brown Pink White Orange Blue Black/Wh Grn/Blk Grn/Wh Brown/Wh Violet/Yel Violet/Yel 100203413 101384550 100203363 — 100203371 100203405 100203389 100203397 — 100203322 100203330 100203348 — 100203355 — — — — KS23751-L10 KS23751-L11 KS23751-L5 — KS23751-L6 KS23751-L9 KS23751-L7 KS23751-L8 — KS23751-L1 KS23751-L2 KS23751-L3 — KS23751-L4 — — — — 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 125V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V 300V Dummy — — — 100203421 — Dummy — — — 103757977 — *Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, December 1988. • Panel mount fuseholder for 70 Type fuses supplied with two screws. • Remote alarm capability. Optional Color Code Eyelets (order separately) Catalog Symbol 1A1706-01 1A1706-02 1A1706-03 1A1706-04 1A1706-05 1A1706-06 1A1706-07 1A1706-08 1A1706-09 Amp Rating Ref. ⁄°Ω¡ºº ¤Ω¡º ⁄Ω¢ ⁄Ω¢ ⁄Ω™ ‹Ω¢ 1 1⁄Ω£ 2 Color Code Yellow Black Violet Violet/White Red Brown Pink White Orange Catalog Symbol Amp Rating Ref. 1A1706-10 1A1706-11 1A1706-12 1A1706-13 1A1706-14 1A1706-15 1A1706-16 1A1706-17 — 3 5 6 8 10 ⁄Ω¡º 3⁄Ω™ ⁄fiΩ¡ºº — Color Code Blue Green/Black Green/White Brown/White Violet/Yellow Gray/White Black/White Red/White — CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 5007 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 5007 185 Telpower® DC Power Protection Systems Bussmann® Indicating Fuses & Holders GMT - Dummy GMT - A (Alarm) GMT HLS, HLT, PCT Fast Acting Fuses Voltage Rating: 60Vdc; 125Vac Interrupting Rating: 450A, 60Vdc; 300A, 125Vac Agency Information: UL Recognized, Guide JFHR2, File E56412 Materials: Body: Thermoplastic, UL 94VO flammability rating Terminals: Tin-plated Beryllium copper Carton Qty. and Weight: 100 Fuses per carton; 0.33 lbs. (150g) Fuseholders: Catalog No. HLT, HLS, and PCT Spare Fuseholder: TPSFH-T Fuseholders for GMT Type Indicating Fuses Voltage Rating: 60Vdc; 125Vac Agency Information: UL Recognized, Guide IZLT2, File E14853, 15A (60Vdc) Materials: Body: Thermoplastic, UL 94VO flammability rating Terminals: Tin-plated copper Catalog Numbers Catalog Symbol GMT-⁄°Ω¡ººA GMT-⁄Ω¢A GMT-‹Ω•A GMT-⁄Ω™A GMT-flfiΩ¡ººA GMT-‹Ω¢A GMT-1A GMT-1⁄Ω£A GMT-1⁄Ω™A GMT-2A Color Code Yellow Violet White/Gray Red Black Brown Gray White White/Yellow Orange Catalog Symbol GMT-3A GMT-3⁄Ω™A GMT-4A GMT-5A GMT-7⁄Ω™A GMT-10A GMT-12A GMT-15A GMT-Dummy GMT-X Color Code Blue White/Blue White/Brown Green Black/White Red/White Yellow/Green Red/Blue Gray Body Clear Cover CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Some GMT sizes may be sold in bulk pack only. GMT-A •The GMT-A is designed specifically for use in the Telpower® series 15800 Fused Disconnect Switch (page 177). • The GMT-A has the same ratings and agency approvals as the standard GMT fuses as shown above. Catalog Symbol GMT-A Data Sheet: 5008 186 Color Code Yellow Multiple Fuseholders with bus bars Ordering Information— Catalog No. Body Style HLT HLS (No flanges) Termination Location No. of Poles 01 thru 25 (Min. of 2 poles required for bus bars) L R (Left only) (Right only) B Type of bus bars used*** B1*, B2, B3, B4, B5, SL** (Short Leads .135") ML** (Medium Leads .250") (Both ends) ** Not available with bus bars Bus Bar Position B1 (Angle Bar Only)* B4 (Angle & “L” Bars) B2 (“L” Bar Only) B3 (“U” Bar Only) P1† (Inside— Both Sides) P2 (Outside— Both Sides) P3 (Outside— Right Only) P4 (Outside— Left Only) B5 (“L” & “U” Bars) *Angle Bar mounts on common or center terminals only. ** SL Version is not available with bus bars. †Minimum of 4 Poles Required. ***.38 max. leads if not specified. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 5010 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Telecommunications Protection Systems Telpower® DC Power Protection Bussmann® Telpower® Specialty Fuses Dimensional Data Dimensional Data A 4.093" 2.685" (68.20mm) .280" (7.11mm) 81 Type 7 Type Description: Cylindrical, fast acting, non-indicating high current companion to the 80 Type. UL Recognized, Guide JDYX2, File E19180. Description: Fiber tube, threaded ends. Typically used on wall type main distribution frames and central battery substations. Catalog Data Catalog Data Catalog Symbol 81B-7⁄Ω™ Ampere Rating 7.5 Voltage Rating ac dc Color Code Lucent Comcode Ref. No. Code/ List No. Catalog Symbol Ampere Rating Lucent Comcode Ref. No. Dimension A Length 250V 65V Gray 103828141 KS23824-L12 7 Type 81A-10 10 250V 65V Yellow 103752176 KS23824-L11 7A-7 7 100863737 4.562 81C-12 12 250V 65V Lt Blue 104391842 KS23824-L13 7T-7 7 100202753 4.828 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data 1.406" .938" A Dimensional Data A .375" 4.625" 4.062" 24 and WER Type Description: Flat, nonindicating visible link element mounted on 1 inch centers using either No. 6 or No. 10 screws. Catalog Data Catalog Ampere Symbol Rating WER-⁄Ω¢ ⁄Ω¢ 24E-⁄Ω™* ⁄Ω™ 24D-‹Ω¢* ‹Ω¢ WER-1 1 24G-1⁄Ω£* 1⁄Ω£ 24C-2* 2 24B-3* 3 WER-3⁄Ω™ 3⁄Ω™ 24B-4* 4 24F-5* 5 WER-8 8 WER-10 10 64A-Dummy — dc Volt. 32V 60V 60V 32V 60V 60V 60V 32V 60V 60V 32V 32V — Color Code — Red Black — White Orange Blue — Yellow Green — — — Lucent Comcode Ref. No. — 100202894 100202886 — 100202910 100202878 100202852 — 100202860 100202902 — — 100203280 Dimension A Length — .200 .150 — .200 .200 .150 — .150 .150 — — — 11 Type Description: Fiber tube, threaded ends, identical to 7 Type except for vent slots in fiber tube. Catalog Data Catalog Symbol Ampere Rating Lucent Comcode Ref. No. Dimension A Length 100863745 — 11 Type 11C-7 7 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. *Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For For complete complete specification specification data, data, call call Bussmann Bussmann Information Information Fax Fax ~~ 636.527.1450 636.527.1450 187 Bussmann® Telecommunications Protection Telpower® Specialty Fuses Dimensional Data Dimensional Data .620" (15.75mm) — —A BUSS 1.25" .325" (8.26mm) .281" (31.75mm) (7.14mm) 74 Type .190" Description: .281∑ ≈ 1.25∑ cylindrical fuse, fast acting. Designed to comply with Lucent specification KS23753. High current companion to 70 Type Fuse. Catalog Data (4.83mm) .800" 75 Type Description: Cylindrical with leads, designed to provide protection against currents resulting from the application of foreign voltages. Application for data sets and telephones. Catalog Symbol Ampere Rating Voltage Rating DC Lucent Comcode Ref. No. Code/ List No. 74A-1⁄Ω¢ 1⁄Ω¢ 60V 102630290 KS23753-L1 Catalog Data Catalog Symbol 74G-2 2 60V 103064952 KS23753-L7 74B-3 3 60V 102630308 KS23753-L2 74H-4 4 60V 103264669 KS23753-L8 74C-5 5 60V 102630316 KS23753-L3 7⁄Ω™ 60V 103228425 KS23753-L9 60V 102630324 KS23753-L4 74J-7⁄Ω™ 74D-10 10 74E-15 15 60V 102630332 KS23753-L5 74F-20 20 60V 102630340 KS23753-L6 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. (20.32mm) Ampere Rating Voltage Rating AC DC Lucent Comcode Ref. No. Code/ List No. KS23825-L3 75C .007 135V 440V 103260816 75F .063 135V 220V 104172861 KS23825-L6 75B .115 135V 220V 102732112 KS23825-L2 75D .129 135V 220V 104013180 KS23825-L4 75A .200 135V 220V 102660008 KS23825-L1 75E .230 135V 220V 104015292 KS23825-L5 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensional Data .445" .830" (11.30mm) (21.08mm) Dimensional Data BUSS — —A 2.685" (68.20mm) .280" (7.11mm) 80 Type .320" (8.13mm) 1.125" (28.58mm) 76 Type Description: Cylindrical with leads, designed to provide protection against currents resulting from the application of foreign voltages. Application for data sets and telephones. Catalog Data Catalog Symbol Ampere Rating Voltage Rating AC DC 76D .012 135V 76B .191 76A 76C Catalog Data Catalog Symbol Voltage Rating AC DC Color Code .50 250V — 1.33 250V — 2 250V 80C-3 3 80D-5 5 Lucent Comcode Ref. No. Code/ List No. 440V 103798245 KS23825-L10 80M-1⁄Ω£ 135V 440V 102965688 KS23825-L8 80B-2 .231 135V 440V 102810181 KS23825-L7 .412 135V 440V 103656625 KS23825-L9 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 188 Description: A fuse designed for high reliability applications where high ambient temperatures, low circuit voltages, low power dissipation and low contact resistance are prime considerations. The 80 Type is a visual indicating fuse with remote electrical alarm capability. UL Recognized, Guide JDYX2, File E19180. 80G-⁄Ω™ Ampere Rating Lucent Comcode Ref. No. Code/ List No. Red 103839916 KS23824-L6 White 408078657 KS23824-L8 — Orange 103752150 KS23824-L2 250V — Blue 103752168 KS23824-L3 250V — Green 103800637 KS23824-L4 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Pg 189 Do not Print Bussmann® British, European, & Canadian Standard Industrial Fuses CSA Type P and Type D Fuses CDS, CDN & PON Dimensional Data Voltage Ratings: 250V (CDN & PON) & 600V (CDS) Interrupting Rating: 10kA minimum Agency Information: CSA Certified to C22.2 No. 59.1 A B Time-Delay CSA Type “D” Volts 250V 600V Cat. No. CDN Amp Ratings Ctn. Qty. Below 10A use FRN-R 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60 10 70, 80, 90, 100 5 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600 1 Below 10A use FRS-R 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60 10 70, 80, 90, 100 5 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600 1 Cat. No. Amp Ratings Ctn. Qty. PON 15, 20, 25, 30, 35, 40, 45, 50, 60 10 CDS Ferrule Design 1 through 60A 250V A Catalog Number and Volts CDN PON 250 Vac Amps Overall Inches (mm) B F B Maximum Diameter Inches (mm) E Knife Blade 70 through 600A CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. One-Time CSA Type “P” Volts A D C C Minimum Blade Length Inches (mm) D Minimum Barrel Length Inches (mm) E Blade Thickness Inches (mm) F Blade Width Inches (mm) 1-30 2.0 (50.8) .56 (14.3) — — — — — — — 35-60 3.0 (76.2) .81 (20.6) — — — — — — — — — 70-100 5.88 (149.4) — — 1.0 (25.4) — — .13 (3.2) .75 (19.1) 110-200 7.3 (185.4) — — 1.38 (34.9) 4.13 (104.8) .19 (4.8) 1.13 (28.6) 225-400 8.63 (219.2) — — 1.88 (47.6) 4.63 (117.5) .25 (6.4) 1.63 (41.3) 450-600 10.38 (263.7) — — 2.25 (57.2) 5.19 (131.8) .25 (6.4) 2 (50.8) 1-30 5.0 (127.0) .81 (20.6) — — — — — — — — 35-60 5.5 (139.7) 1.06 (27.0) — — — — — — — — CDS 70-100 7.88 (200.2) — — 1.0 (25.4) — — .13 (3.2) .75 (19.1) 600V 110-200 9.63 (244.6) — — 1.38 (34.9) 6.13 (115.6) .19 (4.8) 1.13 (28.6) 225-400 11.63 (295.4) — — 1.88 (47.6) 7.13 (118.1) .25 (6.4) 1.63 (41.3) 450-600 13.38 (339.9) — — 2.25 (57.2) 8.19 (208.0) .25 (6.4) 2 (50.8) Data Sheet: 4126 190 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® British, European, & Canadian Standard Industrial Fuses HRC Form II Class C Fuses Dimensional Data 0.22" 0.81" 0.22" (20.64mm) (5.56mm) (5.56mm) 0.06" 2.0" (1.59mm) 0.34" (50.8mm) 2.80" 0.94" (8.73mm) (23.81mm) (71.04mm) 3.31" (84.14mm) CGL 1-30 0.22" 0.81" 0.22" (20.64mm) (5.56mm) (5.56mm) 0.06" 2.0" (50.8mm) (1.59mm) 0.50" 2.80" 1.06" (12.7mm) (71.04mm) (26.92mm) 3.5" CGL (88.9mm) Tron® HRC Form II Class C Fuses Ampere Ratings: 2 to 600A. Voltage Rating: 600Vac, 250Vdc (1-30A) Interrupting Rating: 200,000A (40,000A dc) Current Limiting Agency Information: CSA Certified, C22.2 No. 106 CGL 35-60 0.343" 0.343" (8.71mm) (8.71mm) 2.39" (60.72mm) 3.64" 1.34" (34.04mm) 0.09" (2.29mm) 0.75" 1.375" (19.05mm) (34.93mm) (92.47mm) 4.31" • Tron® HRCII-C fuses are designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. • The Tron® HRCII-C fuses can be sized close to the motor nameplate rating. • Closer protection is offered for many motor sizes with the availability of these additional fuse ratings. • Tron® HRCII-C fuses have a high degree of current limitation greatly reducing the magnetic forces and thermal stresses produced in today’s high capacity systems. (109.54mm) CGL 70-100 0.343" (8.71mm) 0.343 (8.71mm) 0.125" 3.00" (3.18mm) 0.75" (76.2mm) (19.05mm) 4.30" (109.22mm) 1.50" (38.1mm) 5.31" (134.87mm) CGL 110-200 0.19" (4.76mm) Catalog Numbers (Ampere ratings) 1.0" 0.38" (25.4mm) (9.53mm) CGL-1 CGL-40 CGL-175 CGL-2 CGL-45 CGL-200 CGL-3 CGL-50 CGL-225 CGL-4 CGL-60 CGL-250 CGL-6 CGL-70 CGL-300 CGL-10 CGL-80 CGL-350 CGL-15 CGL-90 CGL-400 CGL-20 CGL-100 CGL-450 CGL-25 CGL-110 CGL-500 CGL-30 CGL-125 CGL-600 CGL-35 CGL-150 — 1.0" (25.4mm) 3.0" 2.38" (76.2mm) (60.33mm) 5.25" (133.35mm) 8.19" (207.96mm) CGL 225-400 1.0" 0.41" (25.4mm) (10.32mm) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 1.0" (25.4mm) .60" 3.0" (76.2mm) 5.25" (133.35mm) 8.19" (15.24mm) 0.375" (9.53mm) 3.00" (76.2mm) (207.96mm) CGL 450-600 Data Sheet: 4125 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 191 British, European, & Canadian Standard Industrial Fuses Bussmann® HRCI Industrial Ceramic Body Fuses CIF21 Dimensional Data HRCI-CA Bolt-On Mounting Ampere Ratings: 1-30A Voltage Rating: 600Vac; 250Vdc Interrupting Rating: 200,000A RMS Symmetrical Agency Information: CSA C22.2 No. 106-M92 A C D • Provides both overload and shortcircuit protection to HRCI requirements. • Offset blades for bolt-on mounting. • CIF21 fuse fits the Bussmann-Camaster Fuseholder. E H F G CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensions in Inches and (mm) Type HRCI-CA Catalog Symbol Current Ratings Overall Tags A E F G Mounting H C Body D (AMP) CIF21 1, 3, 10, 15, 20, 25, 30 2.15 (54.50) .44 (11.10) .03 (0.81) 1.75 (44.50) .19 (4.70) 1.44 (35.50) .54 (13.80) Data Sheet: 4127 Dimensional Data A C D E N F • Industrial miniature fuse with offset blades for clip-in mounting. • Ground ceramic body with plated endcaps. • Provides both short-circuit and overload protection. • CIF06 fits the 30A SafeLOC fuseholder. EK fits the 60A SafeLOC fuseholder. CIF06 & EK HRCI-CB Clip-In Mounting Ampere Ratings: CIF06: 1-30A, EK: 35-60A Voltage Rating: 600Vac; 250Vdc Interrupting Rating: 200,000A RMS Symmetrical Agency Information: CSA C22.2 No. 106-M92 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Dimensions in Inches and (mm) Catalog Symbol Current Ratings A E F N C D (AMP) CIF06 1, 10, 15, 20, 25, 30 2.38 (60.40) .50 (12.70) .03 (0.81) .14 (3.50) 1.44 (35.50) .54 (13.80) EK (AMP) 30, 35, 40, 50, 60 2.65 (67.30) .58 (14.80) .05 (1.22) .14 (3.50) 1.44 (36.30) .8 (21.40) Type HRCI-CB Data Sheet: 4128 192 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® British, European, & Canadian Standard Industrial Fuses HRCI-J Fast Acting Fuses Dimensional Data A B B C 1CJ to 60CJ E A K J C F H D B CJ G 70CJ to 600CJ HRCI-J Fast Acting Fuses Voltage Rating: 600Vac or less, 250Vdc Construction: Ceramic Body Fuse Interrupting Rating: 200,000A I.R. Agency Information: CSA C22.2 No. 106 M92; Designed to BS88:2, IEC 60269-2 Current Ratings (Amps) Catalog Number 1 3 6 10 15 20 25 30 1CJ 3CJ 6CJ 10CJ 15CJ 20CJ 25CJ 30CJ 35 40 45 50 60 35CJ 40CJ 45CJ 50CJ 60CJ 70 80 90 100 70CJ 80CJ 90CJ 100CJ 110 125 150 175 200 110CJ 125CJ 150CJ 175CJ 200CJ 225 250 300 350 400 450 500 600 225CJ 250CJ 300CJ 350CJ 400CJ 450CJ 500CJ 600CJ • Industrial duty fuses with ceramic bodies. • The excellent current limiting characteristics of fast-acting HRCI-J fuses limits damage to equipment and installations by the thermal and magnetic energy associated with a large short-circuit fault current. • Overload characteristics limit cable damage due to low overload currents. Dimensions in Inches and (mm) A B C D E F G H J K 2.25 (57) .5 (12.7) .81 (20.6) — — — — — — — 2.38 (60) .63 (16) 1.06 (27) — — — — — — — 4.63 (117) 3.63 (92) 1.13 (28) .75 (19) .13 (3.2) 1 (25.4) .5 (12.7) .28 (7.1) .38 (9.5) 2.63 (67) 5.75 (146) 4.38 (111) 1.63 (41) 1.13 (28.6) .19 (4.8) 1.38 (35) .69 (17.5) .28 (7.1) .38 (9.5) 3 (76) 7.13 (181) 5.25 (133) 2.13 (54) 1.63 (41) .25 (6.3) 1.88 (47.6) .94 (24) .41 (10.3) .53 (13.5) 3.38 (86) 8 (203) 6 (152) 2.63 (66) 2 (51) .38 (9.5) 2.13 (54) 1 (25.4) .53 (13.5) .69 (17.5) 3.75 (96) Data Sheet: 4129 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 193 Bussmann® British, European, & Canadian Standard Industrial Fuses HRCI-Misc. Type K Fuses Dimensional Data CIH, CIK & CIL HRI Ceramic Body Fuses Ampere Ratings: 30, 60 & 100A Voltage Rating: 600V Interrupting Rating: 200,000A at 600V Agency Information: CSA C22.2 No. 106 M92 • Offset blades for bolt down mounting. • Provides both overload and short-circuit protection. K F A D J E G B L C H G (The CIL14 has a rejection hole, not a slot as shown above.) CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Ratings, Categories and Dimensions Dimensions in Inches and (mm) Current Ratings (Amps) Catalog Number 1 3 6 10 15 20 25 30 35 40 50 60 1CIH07 3CIH07 6CIH07 10CIH07 15CIH07 20CIH07 25CIH07 30CIH07 35CIK07 40CIK07 50CIK07 60CIK07 80 90 100 80CIL14 90CIL14 100CIL14 A B C D E F G H J K L Max. Max. Max. Nom. Nom. Nom. Nom. Nom. Max. Nom. Max. 2.25 (57) .94 (24) 3.38 (86) .38 (9.2) .04 (1.0) 2.88 (73) .21 (5.2) .31 (8) 1 (25.4) .10 (2.6) 2.38 (60) 2.28 (58) 1.06 (27) 3.56 (91) .5 (12.7) .05 (1.2) 2.88 (73) .21 (5.2) .41 (10.5) 1.09 (28) .13 (3.2) 2.38 (61) 2.75 (70) 1.44 (37) 4.38 (111) .75 (19) .09 (2.5) 3.69 (94) .34 (8.7) .41 (10.5) 1.5 (38.5) — — 2.91 (74) Recommended Fuseholders Fuse Fuseholder 1-30A CM30CF 35-60A CM60CF 80-100A CM100CF Data Sheet: 4130 194 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® British, European, & Canadian Standard Industrial Fuses HRC Form II Current Limiting Fuses Dimensional Data F G J A E D H07C (Offset Blades) B H C F J E A G K07C/K07CR/ L14C/M14C (Offset Blades) D B H HRC Form II Current Limiting Fuses C Voltage Rating: 600Vac or less, 250Vdc Construction: Ceramic Body Interrupting Rating: 200,000A RMS Symmetrical Agency Information: CSA C22.2 No.106M1992; BS88:2, IEC269:2 C H G B A E F Applications • HRC FORM II fuses are often used to protect motor control circuits, together with contactors and overload protection relays. • Type 2 coordination - per IEC 947-4. K 2 4 6 10 15 20 25 30 40 50 60 80 100 80 100 125 150 200 80 100 125 150 200 250 300 350 400 250 300 350 400 450 500 600 Catalog Number 2H07C 4H07C 6H07C 10H07C 15H07C 20H07C 25H07C 30H07C 40K07C 50K07C 60K07C 80K07CR 100K07CR 80L14C 100L14C 125M14C 150M14C 200M14C 80L09C 100L09C 125M09C 150M09C 200M09C 250P09C 300P09C 350P09C 400P09C 250P11C 300P11C 350P11C 400P11C 450R11C 500R11C 600R11C K F B A G P11C/R11C (Center Blades) D H CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Current Ratings (Amps) L09C/M09C/P09C (Center Blades) D E C Dimensions in Inches and (mm) CSA Category A B C D E F G H J K 1.38 (35) .56 (14) 3.38 (85) .38 (9) .06 (1.2) 2.88 (73) .22 (5.6) .31 (8) .56 (14) — — HRCII-C 2.19 (56) .88 (22) 3.44 (87) .5 (13) .06 (1.2) 2.88 (73) .22 (5.6) .31 (8) .88 (22) — — HRCII-C 2.19 (56) 2.38 (60) .88 (22) .88 (21.4) 3.75 (95) 4.38 (111) .5 (13) .56 (14.3) .06 (1.2) .13 (3.2) 2.88 (73) 3.69 (94) .22 (5.6) .34 (8.7) .31 (8) .44 (11) .88 (22) 1 (25.4) — — — — 2.56 (65) 1.5 (38) 4.38 (111) .75 (19) .09 (2.4) 3.69 (94) .34 (8.7) .44 (11) — — — — HRCII-MISC 2.38 (60) .88 (21.4) 5 (127) .56 (14) .13 (3.2) 4.38 (111) .34 (8.7) .44 (11) — — — — HRCII-MISC 2.56 (65) 1.5 (38) 5.38 (136) .75 (19) .13 (3.2) 4.38 (111) .34 (8.7) .56 (14) — — — — HRCII-C 3.06 (178) 2.31 (59) 5.38 (136) 1 (25.4) .19 (4.8) 4.38 (111) .34 (8.7) .5 (13) — — — — HRCII-MISC 3.06 (178) 2.31 (59) 8.25 (210) 1 (25.4) .19 (5) 5.25 (133) .41 (10) .63 (16) — — 1 25 HRCII-C 3.19 (81) 2.88 (73) 8.25 (210) 1 (25.4) .25 (6.3) 5.25 (133) .41 (10) .63 (16) — — 1 25 HRCII-C HRCII-MISC HRCII-C Data Sheet: 4131 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 195 British, European, & Canadian Standard Industrial Fuses Bussmann® BS88 British Standard Low Voltage Fuses SSD, NSD, ESD STD, NITD, AAO, BAO, OSD, CEO, DEO Offset Blades Meets the requirements of BS88 Part 1 and IEC269-1. The NSD and ESD fuses comply with general purpose gG characteristics. Offset Bolted Blades Meets the requirements of BS88 Part 1 and IEC269-1. The NITD to DEO types comply with general purpose gG characteristics. The STD type are used in 240V street lighting cut-outs. Catalog No. Ampere Ratings SSD 2, 4, 6, 10, 16, 20, 25, 32 NSD 2, 4, 6, 10, 16, 20, 25, 32 20M25*, 20M32* 20M36*, 32M36*, 32M40*, 32M50*, 32M63* Maximum Voltage Rating ac dc BS88 Ref. Data Sheet 4105 240 — E1 550 — F1 Catalog No. Ampere Ratings Maximum Voltage Rating ac dc BS88 Ref. Data Sheet STD 2, 4, 6, 10, 16, 20, 25, 32 240 — — 4123 NITD 2, 4, 6, 10, 16, 20 25, 32 20M25*, 20M32* 32M40*, 32M50*, 32M63* 550 550 550 415 — — — — A1 — A1 — 4106 AAO 2, 4, 6, 10, 16, 20, 25, 32 32M40*, 32M50*, 32M63* 550 550 — — A2 A2 4109 BAO 40, 50, 63 63M80*, 63M100* 550 550 — — A3 A3 4112 Recommended Fuseholders OSD 550 415 — — — — 4107 NSD ESD 80, 100 100M125*, 100M160* CEO 32, 40, 50, 63, 80, 100 100M125*, 100M160* 100M200* 550 415 415 — — — A4 A4 A4 4115 125, 160, 200 200M250*, 200M315* 415 415 — — — — 4117 ESD 2, 4, 6, 10, 16, 25, 32 40, 50, 63 63M80, 63M100 415 415 — — — — 550 415 415 250 250 — F2 F2 — 4100 4101 *“M” indicates motor starter ratings. 32NNSF 63ENSF CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. DEO *“M” indicates motor starter ratings. Recommended Fuseblock & Holders NITD AAO BAO CM32FC CM32F CM63F OSD CEO CM100F BH-0111 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 196 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® British, European, & Canadian Standard Industrial Fuses BS88 British Standard Low Voltage Fuses AC, AD, BC, BD, CD, DD, ED, EFS EF, FF, FG, GF, GG, GH Center Bolted Blades, Two Hole Mount Center Bolted Blades, Four Hole Mount Meets the requirements of BS88 Parts 1 and 2 and IEC269-1. Meets the requirements of BS88 Parts 1 and 2 and IEC269-1. Complies with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with four hole mount. Complies with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with four hole mount. Catalog No. Ampere Ratings Maximum Voltage Rating ac dc 2, 4, 6, 10, 16, 20, 25, 32 550 250 — 4110 2, 4, 6, 10, 16, 20, 25, 32 550 250 — 4111 550 550 250 — BD 40, 50, 63 550 CD 80, 100 100M125*, 100M160* 100M200* 550 415 415 125, 160, 200 200M250*, 200M315* DD ED EFS 355, 400 400M500* 415 550 FF 450, 500, 560, 630 FG 450, 500, 560, 630 Catalog No. AD 40, 50, 63 63M80*, 63M100* EF Data Sheet AC BC Ampere Ratings Maximum Voltage Rating ac dc BS88 Ref. — 4113 250 — 4114 — — — B1 B1 B1 4116 415 415 — — B2 B2 4118 250 315 315M400* 355, 400 400M500* 415 415 415 415 550 — — — — — B3 B3 B3 B4 B4 4119 125, 160, 200, 250 315 415 415 — — — — 4121 BS88 Ref. Data Sheet — — C1 C1 4120 550 400 C2 4102 550 400 — 4122 GF 710, 800 550 250 C3 4103 GG 710, 800 1000, 1250 550 550 250 — — — 4104 GH 710, 800 1000, 1250 550 550 250 — D1 D1 4108 *“M” indicates motor starter ratings. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. *“M” indicates motor starter ratings. Recommended Fuseblock/Holder AC BH-0111 Modular Fuseblock AD 200DF Fuseholder BC BH-0111 Modular Fuseblock BD 200DF Fuseholder CD 200DF Fuseholder DD 200DF Fuseholder ED BH-1131 Modular Fuseblock CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 197 Bussmann® British, European, & Canadian Standard Industrial Fuses DIN Style Type D and Neozed Low Voltage Fuses Type D Fuse Neozed Fuse Ampere Ratings: 2 to 100A. Voltage Ratings: 500Vac Interrupting Rating: 100kA Agency Information: “D” type fuses complying with DIN 49360 Part 2 and DIN 49515, operating class gL Also suitable for use on 250Vdc systems Ampere Ratings: 2 to 63A Voltage Rating: 400Vac Interrupting Rating: 100kA CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Catalog Number 2D16 4D16 6D16 10D16 16D16 20D16 25D16 2D27 4D27 6D27 10D27 16D27 20D27 25D27 35D33 50D33 63D33 80D125 100D125 Dimension “D” 6 6 6 7 10 12 14 6 6 6 8 10 12 14 16 18 20 5 7 Ampere Rating 2 4 6 10 16 20 25 2 4 6 10 16 20 25 35 50 63 80 100 Color Code Pink Brown Green Red Grey Blue Yellow Pink Brown Green Red Grey Blue Yellow Black White Copper Silver Red Figure Number 1 Data Sheet: 4124 198 Figure 2 Figure 3 Dimension D (mm) Ampere Rating Color Code 2NZ01 11 2 4NZ01 11 4 Brown 6NZ01 11 6 Green Pink 10NZ01 11 10 Red 16NZ01 11 16 Grey 20NZ02 15 20 Blue 25NZ02 15 25 Yellow 35NZ02 15 35 Black 50NZ02 15 50 White 63NZ02 15 63 Copper D 2 36 3 4 Additional Fuselinks: Quick acting fuselinks in body sized D16, D27, D33 and D125 rated 2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V. Gauge rings and keys can also be supplied. Figure 1 Catalog Number CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Figure 4 Data Sheet: 4124 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 British, European, & Canadian Standard Industrial Fuses Bussmann® HRC Fuseholders HRC Fuseholders Ampere Ratings: 30, 60 and 100A Agency Information: CSA C22.2 No. 39; IEC 269 AND BS88 • Unique Cam-Action for ease of removal from the Fuse Bases allowing significantly improved contact pressure between Fuse Carrier and Fuse Base contacts, with a corresponding enhanced electrical performance level. • A range of Lockable Safety Carriers for the Fuseholder (Cat ref: LSC), are available. HRC Fuseholders For use with HRCI-CB fuses. Suitable for bolted panel mounting or DIN rail mounting. Ampere Ratings: 30 and 60A Ratings For use with HRCI-CB Fuses Rating Details Fuse Accommodated 30A For HRCI-CA Applications CM20CF —C1F21 30A 60A 100A For HRCII Applications CM30CF CM60CF CM100CF —H07C —K07C —K07CR Catalog Number Fuseholder Accommodated Accessories for Rating Details 30A 30A 60/100A Back Stud All Units 20BS 32BS 60/100BS For CM20CF For CM30CF For CM60/100CF Ganging Link Kit GLP For 3 Pole All 660V Neon Indicator NI 30A 30A Security Carrier 20LSC 30LSC — For CM20CF For CM30CF Fuse Accommodated Connection 30A Front Back Front-Back C30F C30BS C30FBS CIF06 60A Front Back Front-Back C60F C60BS C60FBS EK-Amp Ratings Catalog Number Catalog Number Rating Features • Designed to accommodate the compact range of offset blade fuse to CSA C22.2 No. 106, HRCI-CB. • Carrier provides a positive, stress free fitting of fuse and locks the fuse in position ensuring safe insertion and withdrawal from the base. • Base Contacts are fully shrouded to help protect against electric shock. • Shrouds utilize simple slide/snap action allowing access to the contact terminal screws. • 35mm DIN-rail mounting. • Single screw mounting. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 4132 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Data Sheet: 4133 199 Bussmann® British, European, & Canadian Standard Industrial Fuses NH Low Voltage Fuse Links NH_G NH_M NH_G-690 Voltage Rating: 500Vac gL/gG Category Agency Information: IEC269, VDE, DIN43620 Part 1 A range of industrial fuse links for a wide variety of applications. The ordering code is made up as follows: Voltage Rating: 500Vac aM Category Agency Information: IEC269, VDE, DIN43620 Part 1 A range of industrial fuse links for the protection of motor circuits. The ordering code is made up as follows: Rating Rating Voltage Rating: 690Vac/250Vdc gL/gG Category Agency Information: IEC269, DIN43620 Part 1 A range of industrial fuse links for a wide variety of applications where 690V is needed. The ordering code is made up as follows: 50 Product Code Body Category NH 00 G 100 Product Code Body Category NH 1 M Rating 250 Type Rating (A) Fuse Body Size Type C00 NHC00M 4, 6, 8, 10, 12, 16, 20, 25, 32, 40, 50 63, 80, 100 00 NHC00G 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80, 100 NH00G 125, 160 00 NH00M NH1G 6, 10, 16, 20, 25, 25, 32, 35, 40, 50, 63, 80, 100, 125, 160 200, 224, 225, 250 01 NH1M 35, 40, 50, 63, 80, 100, 125, 160, 200, 224, 250 315, 350, 400, 425 NH2G NH3G NH4AG 1 02 2 100, 125, 160, 200, 224, 250, 315, 350, 400 500, 630 03 800, 1000, 1250, 1600 4a 3 NH2M NH3M Ratings Depth Width Overall Length NHC00G 6-100A 39.5 20.5 78.5 125 & 160A 38 29 78.5 NH00G NH1G 6-160A 45 29 135 NH1G 200-250A 50 44.5 135 NH2G 35-250A 50 44.5 150 NH2G 315-425A 58 50 150 NH3G 100-400A 58 50 150 NH3G 500-630A 73 71 150 NH4AG 800-1000A 102 87 200 NH4AG 1250-1600A 110 95 200 Category 2 G-690 Fuse Body Size Rating (A) C00 40, 50, 63, 80, 100, 125, 160 01 200, 250 02 125, 160, 200, 250 02 315, 400 2 315, 400 03 500, 630 3 Type NH00G-690 NH1G-690 Fuse Body Size Rating (A) 10, 16, 20, 25, 32, 40, 50, 63, 80, 100 C00 32, 40, 50, 63, 80, 100 01 125, 160, 200, 200, 224, 225, 250 1 NH2G-690 100, 125, 160, 200, 224, 250, 315, 350, 400 2 NH3G-690 315, 350, 400, 500, 630 3 Dimensional Detail (mm) Type Ratings Depth Width Ratings Depth Width NH00G-690 10-100A 38 29 78.5 4-50A 39.5 20.5 78.5 NH1G-690 32-100A 45 29 135 NH00M 63-100A 38 29 78.5 NH1G-690 125-250A 50 44.5 135 NH1M 40-160A 45 29 135 NH2G-690 100-400A 50 44.5 150 NH1M 200-250A 50 44.5 135 NH3G-690 315-630A 58 50 150 NH2M 125-250A 50 44.5 150 Data Sheet: 4173 NH2M 315-400A 58 50 150 NH3M 315-400A 58 50 150 NH3M 500-630A 73 71 150 Data Sheet: 4173 CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. For additional information on the IEC Cylindrical Fuse System, visit www.bussmann.co.uk/products.htm Data Sheet: 4173 200 Overall Length Overall Length NHC00M Type Body NH Dimensional Detail (mm) Type Dimensional Detail (mm) Product Code For complete specification data, call Bussmann Information Fax ~ 636.527.1450 British, European, & Canadian Standard Industrial Fuses Bussmann® NH Fuse System SB, TB VLB LBS NH-LV Fuse Bases Voltage Rating: 660Vac Agency Information: DIN43620/1, VDE A range of single and triple pole fuse bases with dimensions to DIN43620/1. The ordering code is made up as follows: Rating: 400 Product Code: SB2 NH-LV Vertical Load Break Fuse Switch Disconnector Agency Information: IEC, DIN43620/1 A range of LV Vertical Load Break Fuse Switch Disconnectors to take NH Fuse Links in sizes 00, 1, 2 and 3. The ordering codes are shown in the table below. NH Fuse Switch Disconnector Agency Information: IEC, VDE, DIN A range of Switch Fuses to take NH fuse link sizes 00, 1, 2 and 3. The ordering codes are shown in the table below. Type Rating (A) Type Rating (A) Fuse Body Size Rating (A) Fuse Body Size LBS00 160 00 LBS1 250 1 400 2 630 3 Type Fuse Body Size* VLB00 160 00 LBS2 250 1 LBS3 SB00 160 00 VLB1 SB1 250 1 VLB2 400 2 SB2 400 2 VLB3 630 3 SB3 630 3 Insulated and touch protected. SB4 1250 4A High Switching capacity. TB00 160 0 Cable terminal top or bottom entry. TB1 250 01 TB2 400 2 SB - Single Pole Base TB - Triple Pole Base *Size 00 is available with “V” shaped terminal lugs, when ordering add “V” to part number i.e. SB00V/TB00V HRC LV Fuse Switch Disconnectors are available for back panel mounting, size 00 can be adapted for DIN rail mounting. A range of accessories are also available. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. N.B. Size 1 bases will accommodate size 0 fuse links. Photo shown with side walls. To order side wall, reference “PB” followed by the fuse body size (i.e. PB00). Vertical Fuse bases in size 00 to size 3 are available, details upon request. Universal Handle: Type 630 for sizes 00 to 3. 1250A size 4A Switchable base available. CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. Data Sheet: 4169 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 201 Bussmann® Fuse Accessories, Displays, Kits, Etc. Accessories Spare Fuseholders • Durable construction using black thermoplastic with UL94-VO flammability rating. • Common mounting using #6 screws or bolts on 5-inch centers. • Dovetailed interlocking between fuseholders simplifies installation and reduces needed hardware. • Common footprint allows for any combination of fuseholders to be mounted together. • Built-in retaining clips secure fuses. Catalog Numbers Capacity TPSFH-T 10-position GMT fuses TPSFH-AS 6-position TPA & TPS fuses TPSFH-N30 4-position Class R (1-30A) fuses TPSFH-N60 1-position Class R (35-60A) fuses TPSFH-LB 1-position Class L (70-250A) series fuses TPSFH-LC 1-position Class L (300-600A) series fuses TPSFH-70 12-position Series 70 fuses (not shown) FP-4 FP-3 FP-2 FP-6 FP-A3 Fusepullers Cat. No. Application SFC-FUSE-CAB Carton Qty. Weight Lbs. Kg. FP-2 ⁄‹Ω£™∑ to ⁄‹Ω¡§∑ dia. fuses 1 .125 .057 FP-3 1∑ to 1‹Ω¢∑ dia. fuses 1 .173 .078 FP-4 1‹Ω¢∑ to 2⁄Ω™∑ dia. fuses 1 .53 FP-6 0-60A T-Tron fuses 1 .123 .056 FP-A3 Glass Tube & ATC fuses 10 0.08 .24 .04 Fuse pullers are only to be used when the associated circuit has been de-energized. For Use With Spare Fuse Cabinet Size: 24∑ wide ≈ 30∑ high x 12∑ deep • Five cubic feet of storage space. • Sturdy storage cabinet conveniently holds spare fuses. • Constructed of heavy gauge steel. • Cabinet door equipped with locking handle. • Durable baked ASA 61 grey enamel. • Mounting holes with key slot 16 inches on center. SFC SHELF • Extra shelf for fuse cabinet. FT-2 5TPH Fuse Tester 24V Maximum • Test automotive, glass tube and ferrule fuses up to 1‡Ω•∑ length. • Batteries are included. WARNING: DO NOT test electrical fuses in the fuse panel. Midget Fuse Spare Fuse Holder Size: 2.98∑ wide ≈1.03∑ high ≈ .63∑ deep • 5-position spare fuse holder for midget size and class CC fuses (⁄‹Ω£™∑ diameter). • Constructed of grey thermoplastic. • Adhesive tape on back for easy mounting on cabinet doors. Data Sheet: 1119 202 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuse Accessories, Displays, Kits, Etc. Accessories Fuse Reducers for Class J Dimension Fuses-LPJ, JKS Fuse (Case) Size Equipment Clip Size Catalog No. (Pair) Reducer No. *Carton Weight (Lbs.) 30A 60A J-63 0.38 30A 100A J-13 1.73 60A 100A J-16 1.85 60A †200A J-26 2.55 100A †200A J-21 1.36 100A †400A J-41 4.90 200A †400A J-42 2.75 200A †600A J-62 1.80 400A †600A J-64 3.55 *Carton quantity—10 pair. †Not for Bolt-on Applications. Dummy Fuse “Neutrals” (These are not fuses) Fuse Equivalent Catalog Numbers NNB NNB-R NNC NTN-R-30 NTN-R-60 NTN-R-100 NTN-R-200 NTN-R-400 NTS-R-30 NTS-R-60 NTS-R-100 NTS-R-200 NTS-R-400 NTS-R-600 Voltage Dimension — — — ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Class CC ⁄Ω¢∑ ≈ 1⁄Ω¢∑ 250V 600V Amperes Carton Quantity — — — 10 10 10 R/H 30A 60A 100A 200A 400A 10 10 5 1 1 R/H 30A 60A 100A 200A 400A 600A 10 10 1 1 1 1 Fuse Reducers for Class R Dimension Fuses FRN-R, LPN-RK—FRS-R, LPS-RK Catalog No. (Pairs) Fuse (Case) Size Equipment Clip Size 250V 600V 30A 60A No. 263-R No. 663-R 30A 60A 100A No. 213-R No. 216-R No. 216-R No. 616-R 60A 100A 200A No. 226-R No. 2621-R No. 626-R No. 2621-R 100A 200A 400A No. 2641-R No. 242-R No. 2641-R No. 642-R 100A 200A 400A 600A No. 2661-R No. 2662-R No. 2664-R** No. 2661-R No. 2662-R No. 2664-R** **Single reducer only (pair not required). Fuse Reducers for Class H & K Dimension Fuses NON, REN—NOS, RES Catalog No. (Pairs) Equipment Fuse (Case) Clip Size Size 250V Reducer No. *Carton Weight (Lbs.) 600V Reducer No. *Carton Weight (Lbs.) 30A 60A No. 263 0.38 No. 663 1.00 30A 100A No. 213 1.73 No. 216 1.73 60A 100A No. 216 1.73 No. 616 1.85 60A 200A No. 226 3.00 No. 626 3.33 100A 200A No. 2621 1.63 No. 2621 1.63 100A 400A No. 2641 4.90 No. 2641 4.90 200A 400A No. 2642 3.50 No. 2642 3.50 100A 600A No. 2661 8.70 No. 2661 8.70 200A 600A No. 2662 6.85 No. 2662 6.85 400A 600A No. 2664 4.45 No. 2664 4.45 *Carton quantity—10 pair. Data Sheet: 1118 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 203 Bussmann® Fuse Accessories, Displays, Kits, Etc. Accessories Adapters for DIN and American Rails TRON Clip-Clamps Clamp Size Volts Amps 0-30A 250 35-60A 0-30A 600 35-60A 70-100A 250 110-200A or 225-400A 600 450-600A Cat. No. No. 1 No. 2 No. 2 No. 4 No. 5 No. 6 No. 7 No. 8 Ctn. Qty. 12 12 12 12 12 6 6 6 Weight Lbs. 0.66 0.96 0.96 1.44 1.20 1.26 1.86 2.52 Kg .30 .44 .44 .65 .54 .57 .84 1.14 • Buss DIN-Rail Adapters permit secure, positive snap-on mounting of Buss 0 to 30 ampere fuseblocks (one, two, or three pole) on the various size rails. (Rail mounting eliminates costly and time consuming drilling, tapping, and screw mounting.) • Molded from “Lexan™ 141”…a very high strength but flexible material. • Adapter mechanically locks into mounting hole of fuseblock in seconds to become an integral part of the block. • One adapter is required for Buss one and two pole blocks. Two adapters are required for three pole blocks. • With the exception of the 32mm DIN-rail, all blocks with adapters can be removed from a rail simply by pulling up its release tab. • Use of rail end-stops on both sides of adapters is recommended. Adapter Catalog Data (For 0-30 Ampere Fuseblocks) Fuseblock Class CC G *H (250V) *R (250) M Type Rails Type DIN American Adapter Size 15mm (Symm.) 32mm (Asymm.) 35mm (Symm.) ⁄‡Ω§¢∑ (Symm.) (also 35mm DIN) Color Cat. No. Black DRA-1 Gray DRA-2 Package Quantities: standard—10; bulk—100 (Cat. No. BK/DRA-1 or BK/DRA-2.) *Mounting on 15mm rails is not recommended. NOTE—New model Buss fuseblocks have elongated block-to-adapter mounting holes (old style fuseblocks will not accept the rail adapters). 204 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuse Accessories, Displays, Kits, Etc. Fuse Display Racks Fusetron® View-Pack Plug Fuse Display Electronic Fuse Display Fuse Display Rack Catalog Symbol: FR-1000 The FR-1000 is a complete assortment of Fusetron View-Packs with a display rack. When you order a “FR-1000”, you receive five each of the View-Packs listed below, plus a heavy-duty wire rack. The rack is designed to hang from a pegboard or stand on a shelf. The FR-1000 measures 32∑ wide, 18∑ tall and 10∑ deep. Catalog Symbol: PFD-948 Sturdy plastic display features complete assortment of plug fuses. Each display comes with a set of labels that permits customizing the product mix. Display measures 29∑ wide x 15∑ tall x 5∑ deep. Catalog Symbol: No.15 A complete assortment of 125 volt and 250 volt fuses for electronic equipment. The No. 15 display contains fifteen of the most popular fuses for electronic equipment, such as microwaves, computers, stereos, CB radios, or office equipment. The sturdy wire rack holds twelve cards of each fuse, and can be hung from a pegboard or stood on a shelf. • Header card explains fuse types and offers safety precautions. • Sturdy wire rack can be hung from a pegboard or stood on a shelf. There is no charge for the rack, when purchased with the display. PFD-948 Display Contents Boxes* Fuses W-15 25 100 Fusetron View-Packs W-20 25 100 Catalog Number W-25 12 48 FRN-R-15-VP W-30 25 100 FRN-R-20-VP TL-15 25 100 FRN-R-25-VP TL-20 25 100 FRN-R-30-VP TL-30 25 100 FRN-R-35-VP SL-15 25 100 FRN-R-40-VP SL-20 25 100 FRN-R-45-VP SL-30 25 100 No. 15 Display and Refills Contents Fuses/ Card Cards/ Display FRN-R-50-VP *Each box contains 4 fuses. BP/AGC-⁄Ω™ 5 5 FRN-R-60-VP Displays without fuses are also available. Order EMPTY-PFD to receive the display only. BP/AGC-1 5 10 BP/AGC-1⁄Ω™ 5 5 BP/AGC-2 5 5 The PFD-948 is packed one per carton. Carton size is 18⁄Ω™∑ ≈ 13⁄Ω™∑ ≈ 31⁄Ω¢∑, weight is 75 lbs. The EMPTY-PFD is also packed one per carton. Carton size is 16∑ ≈ 6∑ ≈ 31⁄Ω¢∑, weight is 6 lbs. BP/AGC-3 5 10 BP/AGC-4 5 5 BP/AGC-5 5 10 FRS-R-15-VP FRS-R-20-VP FRS-R-25-VP FRS-R-30-VP FRS-R-35-VP FRS-R-40-VP FRS-R-45-VP FRS-R-50-VP FRS-R-60-VP BP/MDL-⁄Ω™ 2 5 BP/MDL-1 2 5 BP/MDL-1⁄Ω™ 2 5 BP/MDL-2 2 5 BP/MDL-3 2 5 BP/MDL-5 2 5 BP/ABC-10 2 5 BP/ABC-15 2 5 No. 15 (Display) — 90 Display rack measures: 18⁄Ω¢∑ ≈ 10⁄Ω™∑ ≈ 24∑ For complete specification data, call Bussmann Information Fax ~ 636.527.1450 205 Bussmann® Fuse Accessories, Displays, Kits, Etc. Service Kits Low-Peak® Fuse Fusetron® Fuse Midget Fuse Service Kit Catalog Symbol: LPRK-28 Service Kit Catalog Symbol: ERK-28 • Convenient, compact kit to hold spare fuses. • Sturdy nylon box with handle rugged enough to withstand field use. • Extra spaces and changeable compartments make it easy to customize for your particular need. • Convenient, compact kit to hold spare fuses. • Sturdy nylon box with handle rugged enough to withstand field use. • Extra spaces and changeable compartments make it easy to customize for your particular need. Emergency Kit Quick Service Replacement for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuses Catalog Symbol: No. 36 • A sturdy nylon box is ideal for factory or service truck use. • Cross reference makes it easy to install correct fuse in any application. • Free fuse puller enclosed in box. Contents Contents Contents (2) LPN-RK-3¤Ω¡º SP (2) LPN-RK-40 SP (2) FRN-R-3¤Ω¡º (2) FRN-R-40 (2) LPN-RK-6⁄Ω¢ SP (2) LPN-RK-50 SP (2) FRN-R-6⁄Ω¢ (2) FRN-R-50 (2) LPN-RK-10 SP (3) LPN-RK-60 SP (2) FRN-R-10 (3) FRN-R-60 (2) LPN-RK-15 SP (2) LPN-RK-100 SP (2) FRN-R-15 (2) FRN-R-100 (3) LPN-RK-20 SP (2) No. 263-R Reducers (3) FRN-R-20 (2) No. 263-R Reducers (2) LPN-RK-25 SP (2) No. 1 Clip Clamps (2) FRN-R-25 (2) No. 1 Clip Clamps (4) LPN-RK-30 SP (2) No. 2 Clip Clamps (4) FRN-R-30 (2) No. 2 Clip Clamps (2) LPN-RK-35 SP (1) FP-2 Fusepuller (2) FRN-R-35 (2) FNQ-R-⁄Ω™ (2) KTK-R-1 (2) FNQ-R-1 (2) KTK-R-2 (2) FNQ-R-2 (2) KTK-R-3 (2) FNQ-R-3 (2) KTK-R-5 (2) FNQ-R-4 (2) KTK-R-6 (2) FNQ-R-5 (2) KTK-R-10 (2) FNQ-10 (2) KTK-R-15 (2) FNQ-15 (2) KTK-R-20 (2) FNQ-20 (2) KTK-R-30 (1) FP-2 Kit size: 10‡Ω•∑ ≈ 6fiΩ•∑ ≈ 1‹Ω¢∑. 206 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuse Accessories, Displays, Kits, Etc. Service Kits Small Dimension Fuse Small Dimension Fuse 5mm ≈ 20mm Fuse Assortment Kit Catalog Symbol: No. 270 Voltage Rating: 125V and 250V Contains 270 assorted fuses plus fuseholders, fuseblocks and fuse clips to fit most electronic equipment. Assortment Kit Catalog Symbol: No. 140 Voltage Rating: 125V & 250V Contains 140 assorted fuses plus fuseholders, fuseblocks and fuse clips to fit most electronic equipment. Electronic Fuse Assortment Assortment Kit Catalog Symbol: No. 220 Voltage Rating: 125V & 250V A complete assortment of 125V and 250V 5mm x 20mm size fuses for the repair of both electrical and electronic devices. Electronic Fuse Assortment (5) MDL-⁄Ω• (5) ABC-10 (5) MDL-⁄Ω¢ (5) ABC-15 (5) MDL-⁄Ω™ (5) ABC-20 (5) MDL-‹Ω¢ (5) ABC-30 (5) MDL-1 (5) GMA-250mA (5) MDL-1⁄Ω™ (5) GMA-500mA (5) MDL-2 (5) GMA-1A (5) MDL-3 (5) GMA-2A (5) MDL-4 (5) GMA-3A (5) MDL-5 (5) GMA-4A (5) MDL-6 (5) GMA-6A (5) MDA-8 (5) GMC-1A (5) MDA-10 (5) GMC-2A (5) MDA-15 (5) GMC-3A (5) MDA-20 (5) GMC-4A (5) MDA-30 (5) GMC-6A (5) AGC-⁄Ω• (5) AGC-V-⁄Ω™ (5) AGC-⁄Ω¢ (5) AGC-V-1 (5) AGC-⁄Ω™ (5) AGC-V-2 (5) AGC-‹Ω¢ (5) AGC-V-3 (5) AGC-1 (5) MDL-V-⁄Ω™ (5) AGC-1⁄Ω™ (5) MDL-V-1 (5) AGC-2 (5) MDL-V-2 (5) AGC-2⁄Ω™ (5) MDL-V-3 (5) AGC-3 (1) S-8202-2 (5) AGC-4 (1) HTB-26I (5) AGC-5 (1) HTB-28M (5) AGC-6 (2) Pr. 4121 Fuseclips (5) AGC-7 (2) HHB Contents (5) MDL-⁄Ω™ (5) AGC-1⁄Ω™ (5) MDL-1 (5) AGC-2 (5) MDL-1⁄Ω™ (5) AGC-3 (5) MDQ-2 (5) MTH-4 (5) MDQ-3 (5) MTH-5 GDA 630ma, 1, 2, 3.15, 5, 6.3 (5) MDQ-4 (5) MTH-6 GDB 630ma, 2, 3.15, 4 (5) MDQ-5 (5) MTH-7 GMC (5) MDQ-6 (5) MTH-8 500ma, 750ma, 1, 2, 2.5, 3, 3.15, 4, 5, 6.3 (5) MDA-8 (5) ABC-10 GMD 200ma, 500ma, 1, 1.6, 2, 3 (5) MDA-10 (5) ABC-15 GDC (5) MDA-15 (5) ABC-20 250ma, 500ma, 1, 1.6, 2, 3.15, 4, 5 (5) MDA-20 (5) ABC-30 (5) MDA-30 (2) Pr. #4121 Fuseclips (5) AGC-⁄Ω¢ (2) HHB (5) AGC-⁄Ω™ (1) FP-A3 Product Type GMA Ampere Ratings Contains 5 each 250ma, 500ma, 1, 1.5, 2, 2.5, 3, 4, 5, 10 HTB-28m, FP-A3 (5) AGC-1 (5) AGC-8 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 207 Bussmann® Fuse Accessories, Displays, Kits, Etc. Fuse Display Racks No. 2880 Empty Counter or Wall Stock Display Rack • Holds 2880 fuses (574 boxes of 5 each). • Six removable sections with four channels. Units may be interlocked without screws. Electronic Fuse Display No. 200 & No. 201 Catalog Symbol: No. 205 Compact display of 125V and 250V fuses. Size: 6‹Ω¢∑ W ≈ 16∑ H x 4∑ D Glass Tube and Blade-Type Automotive Fuses The “200”—40 boxes (172 fuses). Size: 4∑ ≈ 6‹Ω¢∑ x 10∑ (270 cu. in.) Fuse Quantity Fuse Quantity Fuse Quantity Fuse Quantity AGC-⁄Ω™ AGC-1 AGC-1⁄Ω™ AGC-2 AGC-3 AGC-4 AGC-5 AGC-6 AGC-7 AGC-8 AGC-10 ABC-10 ABC-15 ABC-20 MDL⁄Ω™ 5 10 5 10 10 5 10 5 5 5 5 5 15 5 5 MDL-1 MDL-1⁄Ω™ MDL-2 MDL-3 MDL-4 MDL-5 MDL-6 MDL-7 MDL-8 GLH-7 GMA-500mA GMA-1A GMA-2A GMA-3A GMA-5A 10 5 10 10 5 5 5 5 5 15 5 5 5 5 5 AGC-1 AGC-2 AGC-3 AGC-5 AGC-7⁄Ω™ AGC-10 AGC-15 AGC-20 AGC-25 AGC-30 ATC-3 ATC-4 ATC-5 ATC-7⁄Ω™ ATC-10 ATC-15 ATC-20 ATC-25 ATC-30 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 ATM-2 ATM-3 ATM-4 ATM-5 ATM-7⁄Ω™ ATM-10 ATM-15 ATM-20 ATM-25 ATM-30 GBC-8 MAX-20 MAX-30 MAX-40 MAX-50 MAX-60 SFE-14 SFE-20 5 5 5 5 5 5 5 5 5 5 5 5 5 2 1 2 5 5 The “201”—40 boxes (172 fuses). Comes in handy, clear plastic service kit. Fuse assortment same as the “200”. 3∑ ≈ 4∑ x 10∑ (142.5 cu. in.) Christmas Light Fuses and Displays Bussmann offers a comprehensive line of replacement fuses for all Christmas tree lights and decorative light products. Display Cartons Part No. BP/AGX-7X5 BP/GLH-7X5 BP/MAS-3X5 BP/XMAS-6F Carton Quantity Description 5 AGX-7A, 125V Fuses ⁄Ω¢∑ ≈ 1∑ Glass Tube 5 GLH-7A, 125V Fuses ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Glass Tube 5 MAS-3A, 125V Fuses 3.6mm x 10mm Glass Tube Assortment: 6 Fuses (2 ea. AGX-7, GLH-7, MAS-3) 20 Cards 20 Cards 20 Cards 20 Cards Clip Strip CS/XMAS-6F Assortment: 6 Fuses 20 Cards (2 ea. AGX-7, GLH-7, MAS-3) Note: Order by the card (each in multiples of 20). Package Specifications Card Size 208 Display Carton Part No. H W D H W Weight BP/AGX-7X5 BP/GLH-7X5 BP/MAS-3X5 BP/XMAS-6F CS/XMAS-6F 4‹Ω¢∑ 4‹Ω¢∑ 4‹Ω¢∑ 4‹Ω¢∑ 4‹Ω¢∑ 2‹Ω¢∑ 2‹Ω¢∑ 2‹Ω¢∑ 2‹Ω¢∑ 2‹Ω¢∑ 7⁄Ω¢∑ 7⁄Ω¢∑ 7⁄Ω¢∑ 7⁄Ω¢∑ 6⁄Ω™∑ 6⁄Ω¢∑ 6⁄Ω¢∑ 6⁄Ω¢∑ 6⁄Ω¢∑ 2‡Ω•∑ 5‹Ω¢∑ 5‹Ω¢∑ 5‹Ω¢∑ 5‹Ω¢∑ 6⁄Ω¢∑ 1 lb. 10 oz. 1 lb. 10 oz. 1 lb. 10 oz. 1 lb. 10 oz. 1 lb. 4 oz. For complete specification data, call Bussmann Information Fax ~ 636.527.1450 Bussmann® Fuse Accessories, Displays, Kits, Etc. Fuse Display Racks FSD FDM-1 Fuse Display Merchandiser • Bussmann tilt-bin display maximizes your space and stimulates impulse purchases. • Interlocking bins can be stacked or mounted on peg board. • Header card easily attaches with plastic push pegs. • Provides a flexible system to best fit your needs and space requirements. • The tilt bins are available in five and six bin models. Fuse Display Merchandiser will consist of any number of either size bins; header card push pegs to attach and part number labels. Part Number Key Features & Benefits: • Prominent “Silent Salesman”. • Sturdy Steel Construction. • Selection of fastest selling sizes and amps. • Flip chart for applications, cross referencing and fuse types. • Clear tilt bins allow for quick identification, easy access, inventory restocking. • Heavy duty casters allow for easy repositioning. • Modular system provides flexibility for growth by joining two or more units together. (Back-to-back or side-by-side). • Product part number adhesive labels. • Standard Gondola Measures: 24" wide x 66" tall x 21⁄Ω™" deep Part Number Carton Quantity Part Number Carton Quantity Part Number Carton Quantity Description FNQ-R-1/4 10 FNM-15 10 NON-35 10 1A9721 5 Bin Display 23fiΩ• long x 6⁄Ω™ tall x 5⁄Ω™ deep FNQ-R-1/2 10 LP-CC-5 10 NON-40 10 1A9722 6 Bin Display 23fiΩ• long x 4⁄Ω™ tall x 3fiΩ• deep FNQ-R-1 10 LP-CC-10 10 NON-45 10 FNQ-R-1-1/2 10 LP-CC-15 10 NON-50 10 FNQ-R-2 10 LP-CC-20 10 NON-60 10 FNQ-R-3 10 LP-CC-30 10 T-15 4 FNQ-R-4 10 FRN-R-5 10 T-20 4 FNQ-R-5 10 FRN-R-10 10 T-30 4 FNQ-R-10 10 FRN-R-15 10 W-15 4 FNQ-15 10 FRN-R-20 10 W-20 FNQ-20 10 FRN-R-25 10 FRS-R-5 10 FNQ-25 10 FRN-R-30 10 FRS-R-10 10 FNQ-30 10 FRN-R-35 10 FRS-R-15 10 FP2 10 FRN-R-40 10 FRS-R-20 10 FP3 10 FRN-R-45 10 FRS-R-25 10 KTK-R-5 10 FRN-R-50 10 FRS-R-30 10 KTK-R-10 10 FRN-R-60 10 FRS-R-35 10 KTK-R-15 10 NON-3 10 FRS-R-40 10 KTK-R-20 10 NON-6 10 FRS-R-50 10 KTK-R-30 10 NON-10 10 FRS-R-60 10 FNM-2 10 NON-15 10 FRS-R-100 1 FNM-5 10 NON-20 10 FRS-R-200 1 FNM-10 10 NON-30 10 For complete specification data, call Bussmann Information Fax ~ 636.527.1450 4 209 Fuse Technology Circuit Protection Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration, accidental damage, damage from natural causes, excessive expansion, and/or overloading of the electrical distribution system are factors which contribute to the occurrence of such overcurrents. Reliable protective devices prevent or minimize costly damage to transformers, conductors, motors, and the other many components and loads that make up the complete distribution system. Reliable circuit protection is essential to avoid the severe monetary losses which can result from power blackouts and prolonged downtime of facilities. It is the need for reliable protection, safety, and freedom from fire hazards that has made the fuse a widely used protective device. Overcurrents An overcurrent is either an overload current or a short-circuit current. The overload current is an excessive current relative to normal operating current, but one which is confined to the normal conductive paths provided by the conductors and other components and loads of the distribution system. As the name implies, a short-circuit current is one which flows outside the normal conducting paths. Overloads Overloads are most often between one and six times the normal current level. Usually, they are caused by harmless temporary surge currents that occur when motors are started-up or transformers are energized. Such overload currents, or transients, are normal occurrences. Since they are of brief duration, any temperature rise is trivial and has no harmful effect on the circuit components. (It is important that protective devices do not react to them.) Continuous overloads can result from defective motors (such as worn motor bearings), overloaded equipment, or too many loads on one circuit. Such sustained overloads are destructive and must be cut off by protective devices before they damage the distribution system or system loads. However, since they are of relatively low magnitude compared to short-circuit currents, removal of the overload current within minutes will generally prevent equipment damage. A sustained overload current results in overheating of conductors and other components and will cause deterioration of insulation, which may eventually result in severe damage and short-circuits if not interrupted. Short-Circuits Whereas overload currents occur at rather modest levels, the short-circuit or fault current can be many hundred times larger than the normal operating current. A high level fault may be 50,000A (or larger). If not cut off within a matter of a few thousandths of a second, damage and destruction can become 210 Bussmann® rampant—there can be severe insulation damage, melting of conductors, vaporization of metal, ionization of gases, arcing, and fires. Simultaneously, high level short-circuit currents can develop huge magnetic-field stresses. The magnetic forces between bus bars and other conductors can be many hundreds of pounds per linear foot; even heavy bracing may not be adequate to keep them from being warped or distorted beyond repair. Fuses The fuse is a reliable overcurrent protective device. A “fusible” link or links encapsulated in a tube and connected to contact terminals comprise the fundamental elements of the basic fuse. Electrical resistance of the link is so low that it simply acts as a conductor. However, when destructive currents occur, the link very quickly melts and opens the circuit to protect conductors and other circuit components and loads. Fuse characteristics are stable. Fuses do not require periodic maintenance or testing. Fuses have three unique performance characteristics: 1. Modern fuses have an extremely “high interrupting rating”—can withstand very high fault currents without rupturing. 2. Properly applied, fuses prevent “blackouts.” Only the fuse nearest a fault opens without upstream fuses (feeders or mains) being affected—fuses thus provide “selective coordination.” (These terms are precisely defined in subsequent pages.) 3. Fuses provide optimum component protection by keeping fault currents to a low value…They are said to be “current limiting.” Voltage Rating The voltage rating of a fuse must be at least equal to or greater than the circuit voltage. It can be higher but never lower. For instance, a 600V fuse can be used in a 208V circuit. The voltage rating of a fuse is a function of its capability to open a circuit under an overcurrent condition. Specifically, the voltage rating determines the ability of the fuse to suppress the internal arcing that occurs after a fuse link melts and an arc is produced. If a fuse is used with a voltage rating lower than the circuit voltage, arc suppression will be impaired and, under some fault current conditions, the fuse may not clear the overcurrent safely. Special consideration is necessary for semiconductor fuse and medium voltage fuse applications, where a fuse of a certain voltage rating is used on a lower voltage circuit. Ampere Rating Every fuse has a specific ampere rating. In selecting the ampere rating of a fuse, consideration must be given to the type of load and code requirements. The ampere rating of a fuse normally should not exceed the current carrying capacity of the circuit. For Bussmann® Fuse Technology instance, if a conductor is rated to carry 20A, a 20A fuse is the largest that should be used. However, there are some specific circumstances in which the ampere rating is permitted to be greater than the current carrying capacity of the circuit. A typical example is the motor circuit; dual-element fuses generally are permitted to be sized up to 175% and non-time-delay fuses up to 300% of the motor full-load amperes. As a rule, the ampere rating of a fuse and switch combination should be selected at 125% of the continuous load current (this usually corresponds to the circuit capacity, which is also selected at 125% of the load current). There are exceptions, such as when the fuse-switch combination is approved for continuous operation at 100% of its rating. Interrupting Rating A protective device must be able to withstand the destructive energy of short-circuit currents. If a fault current exceeds the capability of the protective device, the device may actually rupture, causing additional damage. Thus, it is important when applying a fuse or circuit breaker to use one which can sustain the largest potential short-circuit currents. The rating which defines the capacity of a protective device to maintain its integrity when reacting to fault currents is termed its “interrupting rating”. The interrupting rating of most branch-circuit, molded case, circuit breakers typically used in residential service entrance panels is 10,000A. (Please note that a molded case circuit breaker’s interrupting capacity will typically be lower than its interrupting rating.) Larger, more expensive circuit breakers may have interrupting ratings of 14,000A or higher. In contrast, most modern, current-limiting fuses have an interrupting rating of 200,000 or 300,000A and are commonly used to protect the lower rated circuit breakers. The National Electrical Code, Section 110-9, requires equipment intended to break current at fault levels to have an interrupting rating sufficient for the current that must be interrupted. Selective Coordination – Prevention of Blackouts The coordination of protective devices prevents system power outages or blackouts caused by overcurrent conditions. When only the protective device nearest a faulted circuit opens and larger upstream fuses remain closed, the protective devices are “selectively” coordinated (they discriminate). The word “selective” is used to denote total coordination…isolation of a faulted circuit by the opening of only the localized protective device. KRP-C 1200SP LPS-RK 600SP LPS-RK 200SP 2:1 (or more) 2:1 (or more) This diagram shows the minimum ratios of ampere ratings of LOW-PEAK YELLOW fuses that are required to provide “selective coordination” (discrimination) of upstream and downstream fuses. Unlike electro-mechanical inertial devices (circuit breakers), it is a simple matter to selectively coordinate fuses of modern design. By maintaining a minimum ratio of fuse-ampere ratings between an upstream and downstream fuse, selective coordination is assured. Current Limitation – Component Protection Areas within waveform loops represent destructive energy impressed upon circuit components Normal load current Initiation of short-circuit current Circuit breaker trips and opens short-circuit in about 1 cycle A non-current-limiting protective device, by permitting a shortcircuit current to build up to its full value, can let an immense amount of destructive short-circuit heat energy through before opening the circuit. Fuse opens and clears short-circuit in less than cycle A current-limiting fuse has such a high speed of response that it cuts off a short-circuit long before it can build up to its full peak value. If a protective device cuts off a short-circuit current in less than one-quarter cycle, before it reaches its total available (and highly destructive) value, the device is a “current-limiting” device. Most modern fuses are current-limiting. They restrict fault currents to such low values that a high degree of protection is given to circuit components against even very high short-circuit currents. They permit breakers with lower interrupting ratings to be used. They can reduce bracing of bus structures. They minimize the need of other components to have high short-circuit current “withstand” ratings. If not limited, short-circuit currents can reach levels of 30,000 or 40,000A or higher in the first half cycle (.008 seconds, 60 hz) after the start of a short-circuit. The heat that can be produced in circuit components by the immense energy of short-circuit currents can cause severe insulation damage or even explosion. At the same time, huge magnetic forces developed between conductors can crack insulators and distort and destroy bracing structures. Thus, it is important that a protective device limit fault currents before they reach their full potential level. 211 Fuse Technology Bussmann® Operating Principles of Bussmann® Fuses The principles of operation of the modern, current-limiting Buss fuses are covered in the following paragraphs. Non-Time-Delay Fuses The basic component of a fuse is the link. Depending upon the ampere rating of the fuse, the single-element fuse may have one or more links. They are electrically connected to the end blades (or ferrules) (see Figure 1) and enclosed in a tube or cartridge surrounded by an arc quenching filler material. BUSS® LIMITRON® and T-TRON® fuses are both single-element fuses. Under normal operation, when the fuse is operating at or near its ampere rating, it simply functions as a conductor. However, as illustrated in Figure 2, if an overload current occurs and persists for more than a short interval of time, the temperature of the link eventually reaches a level which causes a restricted segment of the link to melt. As a result, a gap is formed and an electric arc established. However, as the arc causes the link metal to burn back, the gap becomes progressively larger. Electrical resistance of the arc eventually reaches such a high level that the arc cannot be sustained and is extinguished. The fuse will have then completely cut off all current flow in the circuit. Suppression or quenching of the arc is accelerated by the filler material. (See Figure 3.) Single-element fuses of present day design have a very high speed of response to overcurrents. They provide excellent shortcircuit component protection. However, temporary, harmless overloads or surge currents may cause nuisance openings unless these fuses are oversized. They are best used, therefore, in circuits not subject to heavy transient surge currents and the temporary over-load of circuits with inductive loads such as motors, transformers, solenoids, etc. Because single-element, fast-acting fuses such as LIMITRON and T-TRON fuses have a high speed of response to short-circuit currents, they are particularly suited for the protection of circuit breakers with low interrupting ratings. Whereas an overload current normally falls between one and six times normal current, short-circuit currents are quite high. The fuse may be subjected to short-circuit currents of 30,000 or 40,000A or higher. Response of current limiting fuses to such currents is extremely fast. The restricted sections of the fuse link will simultaneously melt (within a matter of two or three-thousandths of a second in the event of a high-level fault current). The high total resistance of the multiple arcs, together with the quenching effects of the filler particles, results in rapid arc suppression and clearing of the circuit. (Refer to Figures 4 & 5) Shortcircuit current is cut off in less than a half-cycle, long before the short-circuit current can reach its full value (fuse operating in its current limiting range). 212 Figure 1. Cutaway view of typical single-element fuse. Figure 2. Under sustained overload, a section of the link melts and an arc is established. Figure 3. The “open” single-element fuse after opening a circuit overload. Figure 4. When subjected to a short-circuit current, several sections of the fuse link melt almost instantly. Figure 5. The “open” single-element fuse after opening a short circuit. Bussmann® Fuse Technology Bussmann Dual-Element Fuses ® There are many advantages to using these fuses. Unlike single-element fuses, the Bussmann® dual-element, time-delay fuses can be sized closer to provide both high performance shortcircuit protection and reliable overload protection in circuits subject to temporary overloads and surge currents. For ac motor loads, a single-element fuse may need to be sized at 300% of an a.c. motor current in order to hold the starting current. However, dual-element, time delay fuses can be sized much closer to motor loads. For instance, it is generally possible to size FUSETRON® Dual-Element Fuses, FRS-R and FRN-R and LOW-PEAK® Dual-Element Fuses, LPS-RK_SP and LPN-RK_SP, at 125% and 130% of motor full load current, respectively. Generally, the LOWTM PEAK® Dual-Element Fuses, LPJ_SP, and CUBEFuse , TCF, can be sized at 150% of motor full load amperes. This closer fuse sizing may provide many advantages such as: (1) smaller fuse and block, holder or disconnect ampere rating and physical size, (2) lower cost due to lower ampere rated devices and possibly smaller required panel space, (3) better short-circuit protection – less short-circuit current let-through energy, and (4) potential reduction in the arc flash hazard. Insulated end-caps to help prevent accidental contact with live parts. Filler material Figure 6. This is the LPS-RK100SP, a 100A, 600V LOW-PEAK®, Class RK1, Dual-Element Fuse that has excellent time-delay, excellent current-limitation and a 300,000A interrupting rating. Artistic liberty is taken to illustrate the internal portion of this fuse. The real fuse has a non-transparent tube and special small granular, arc-quenching material completely filling the internal space. Small volume of metal to vaporize Short-circuit element Overload element Figure 7. The true dual-element fuse has distinct and separate overload element and short-circuit element. Figure 9. Short-circuit operation: Modern fuses are designed with minimum metal in the restricted portions which greatly enhance their ability to have excellent current-limiting characteristics – minimizing the short circuit let-through current. A short-circuit current causes the restricted portions of the short-circuit element to vaporize and arcing commences. The arcs burn back the element at the points of the arcing. Longer arcs result, which assist in reducing the current. Also, the special arc quenching filler material contributes to extinguishing the arcing current. Modern fuses have many restricted portions, swhich results in many small arclets – all working together to force the current to zero. Before Filler quenches the arcs Spring After Figure 8. Overload operation: Under sustained overload conditions, the trigger spring fractures the calibrated fusing alloy and releases the “connector”. The insets represent a model of the overload element before and after. The calibrated fusing alloy connecting the short-circuit element to the overload element fractures at a specific temperature due to a persistant overload current. The coiled spring pushes the connector from the short-circuit element and the circuit is interrupted. Figure 10. Short-circuit operation: The special small granular, arc-quenching material plays an important part in the interruption process. The filler assists in quenching the arcs; the filler material absorbs the thermal energy of the arcs, fuses together and creates an insulating barrier. This process helps in forcing the current to zero. Modern current-limiting fuses, under short-circuit conditions, can force the current to zero and complete the interruption within a few thousandths of a second. When the short-circuit current is in the current-limiting range of a fuse, it is not possible for the full available short-circuit current to flow through the fuse – it’s a matter of physics. The small restricted portions of the short-circuit element quickly vaporize and the filler material assists in forcing the current to zero. The fuse is able to “limit” the short-circuit current. Overcurrent protection must be reliable and sure. Whether it is the first day of the electrical system or thirty or more years later, it is important that overcurrent protective devices perform under overload or short-circuit conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles. 213 Bussmann® Fuse Technology This particular plot reflects the characteristics of a 200A, 250V, LOW-PEAK YELLOW dual-element fuse. Note that at the 1,000A overload level, the time interval which is required for the fuse to open is 10 seconds. Yet, at approximately the 2,200A overcurrent level, the opening (melt) time of a fuse is only 0.01 seconds. It is apparent that the time intervals become shorter as the overcurrent levels become larger. This relationship is termed an inverse time-to-current characteristic. Time-current curves are published or are available on most commonly used fuses showing “minimum melt,” “average melt” and/or “total clear” characteristics. Although upstream and downstream fuses are easily coordinated by adhering to simple ampere ratios, these time-current curves permit close or critical analysis of coordination. Better Motor Protection in Elevated Ambients The derating of dual-element fuses based on increased ambient temperatures closely parallels the derating curve of motors in elevated ambient. This unique feature allows for optimum protection of motors, even in high temperatures. Affect of ambient temperature on operating characteristics of FUSETRON 400 300 200 LOW-PEAK YELLOW LPN-RK200 SP (RK1) 100 80 60 40 30 20 10 8 6 TIME IN SECONDS Fuse Time-Current Curves When a low level overcurrent occurs, a long interval of time will be required for a fuse to open (melt) and clear the fault. On the other hand, if the overcurrent is large, the fuse will open very quickly. The opening time is a function of the magnitude of the level of overcurrent. Overcurrent levels and the corresponding intervals of opening times are logarithmically plotted in graph form as shown to the right. Levels of overcurrent are scaled on the horizontal axis; time intervals on the vertical axis. The curve is thus called a “time-current” curve. 4 3 2 1 .8 .6 .4 .3 .2 150 140 PERCENT OF RATING OR OPENING TIME 130 .1 .08 .06 Affect on Carrying Capacity Rating 120 110 100 .04 90 80 70 .03 Affect on Opening Time .02 60 50 AMBIENT and LOW-PEAK YELLOW Dual-Element Fuses. 214 176°F (80°C) 212°F (100°C) CURRENT IN AMPERES 6,000 8,000 10,000 140°F (60°C) 3,000 4,000 104°F (40°C) 2,000 68°F (20°C) 600 800 1,000 –32°F (0°C) 300 400 –76°F –40°F –4°F (–60°C) (–40°C) (–20°C) 200 30 100 .01 40 Fuse Technology Bussmann® Better Protection Against Motor Single Phasing When secondary single-phasing occurs, the current in the remaining phases increases to approximately 200% rated full load current. (Theoretically 173%, but change in efficiency and power factor make it about 200%.) When primary single-phasing occurs, unbalanced voltages occur on the motor circuit causing currents to rise to 115%, and 230% of normal running currents in delta-wye systems. Dual-element fuses sized for motor running overload protection will help to protect motors against the possible damages of single-phasing. Classes of Fuses Safety is the industry mandate. However, proper selection, overall functional performance and reliability of a product are factors which are not within the basic scope of listing agency activities. In order to develop its safety test procedures, listing agencies develop basic performance and physical specifications or standards for a product. In the case of fuses, these standards have culminated in the establishment of distinct classes of low-voltage (600V or less) fuses; classes RK1, RK5, G, L, T, J, H and CC being the more important. The fact that a particular type of fuse has, for instance, a classification of RK1, does not signify that it has the identical function or performance characteristics as other RK1 fuses. In fact, the LIMITRON® non-time-delay fuse and the LOW-PEAK YELLOW™ dual-element, time-delay fuse are both classified as RK1. Substantial differences in these two RK1 fuses usually requires considerable difference in sizing. Dimensional specifications of each class of fuse does serve as a uniform standard. In the above illustration, a grooved ring in one ferrule provides the rejection feature of the Class R fuse in contrast to the lower interrupting rating, non-rejection type. Branch-Circuit Listed Fuses Branch-circuit listed fuses are designed to prevent the installation of fuses that cannot provide a comparable level of protection to equipment. The characteristics of Branch-circuit fuses are: 1. They must have a minimum interrupting rating of 10,000A 2. They must have a minimum voltage rating of 125V. 3. They must be size rejecting such that a fuse of a lower voltage rating cannot be installed in the circuit. 4. They must be size rejecting such that a fuse with a current rating higher than the fuseholder rating cannot be installed. Class R Fuses Class R (“R” for rejection) fuses are high performance, ⁄Ω¡º to 600A units, 250V and 600V, having a high degree of current limitation and a short-circuit interrupting rating of up to 300,000A (rms symmetrical). BUSS Class R's include Classes RK1 LOW-PEAK YELLOW™ and LIMITRON® fuses, and RK5 FUSETRON® fuses. They have replaced BUSS K1 LOW-PEAK and LIMITRON fuses and K5 FUSETRON fuses. These fuses are identical, with the exception of a modification in the mounting configuration called a “rejection feature”. This feature permits Class R fuses to be mounted in rejection type fuseclips. “R” type fuseclips prevent older type Class H, ONE-TIME and RENEWABLE fuses from being installed. The use of Class R fuseholders is thus an important safeguard. The application of Class R fuses in such equipment as disconnect switches permits the equipment to have a high interrupting rating. NEC Articles 110-9 and 230-65 require that protective devices have adequate capacity to interrupt short-circuit currents. Article 240-60(b) requires fuseholders for current-limiting fuses to reject non-current-limiting type fuses. 215 Transformers (N.E.C. 450-3) 216 600V Nominal or Less Over 600V Nominal Primary and Secondary Protection Primary Protection Only Un-Supervised Installations Supervised Installations With Thermal Overload Protection Without Thermal Overload Protection Based on 1996 N.E.C.® Transformer Impedance of More Than 6% But Less Than 10% Transformer Impedance of 6% or Less Rated secondary current 9 amps or greater. Rated secondary current less than 9 amps. Rated secondary current 9 amps or greater. F E D F E D C C Primary and secondary fuses at 125% of primary and secondary F.L.A. or next size larger. B Rated secondary current 9 amps or greater. Rated secondary current less than 9 amps. B A Rated secondary current less than 9 amps. 125% or next size larger 125% or next size larger Rated primary current greater than or equal to 2 amps but less than 9 amps. Rated primary current greater than or equal to 9 amps. 125% or next size larger (LPN-RK_SP, LPS-RK_SP, FRN-R, FRS-R) A Secondary 600V or Below 250% 250% 600% 600% 400% 400% 167% or next size smaller. 125% or next size larger.* 167% or next size smaller. 125% or next size larger.* 167% or next size smaller. 125% or next size larger.* *When 125% of F.L.A. corresponds to a standard rating, the next larger size is not permitted. A B C D E F Maximum Fuse Size % of Primary % of Secondary F.L.A. (Or next F.L.A. size smaller.) Max. of 125% or next larger*. Max. 300% or next size smaller. (See N.E.C. 430-72(c) for control circuit transformer maximum of 500%. Max. 167% or next size smaller. N.E.C. MAXIMUMS (All Fuse Types Shown) Secondary at code max. of 125% or next standard size if 125% does not correspond to a standard rating. Secondary at code max. of 225% or next standard size if 225% does not correspond to a standard rating. Secondary Over 600V OPTIMUM PROTECTION Primary at code max. of 300% or next standard size if 300% does not correspond to a standard rating. Secondary at code max. of 125% or next standard size if 125% does not correspond to a standard rating. Secondary 600V or Below Secondary at code max. of 250% or next standard size if 250% does not correspond to a standard rating. Secondary at code max. of 250%. Secondary 600V or Below Secondary Over 600V Secondary at code max. of 225%. Secondary at code max. of 250%. Secondary at code max. of 250%. Secondary Over 600V Secondary 600V or Below Secondary Over 600V (Note: Components on the secondary still need overcurrent protection.) Rated primary current less than 2 amps. Transformer Impedance Greater Than 6% But Less Than 10%. Primary at code max. of 300% or next standard size if 300% does not correspond to a standard rating. Transformer Impedance Greater Than 6% But Less Than 10%. Transformer Impedance Less Than or Equal to 6%. Primary at code max. of 300% Transformer Impedance Less Than or Equal to 6%. Primary at code max. of 250% or next standard size if 250% does not correspond to a standard rating. Primary at code max. of 300% (Note: Components on the secondary still need overcurrent protection.) Primary and Secondary Protection Primary Protection Only 600V KRP-C_SP, LPJ_SP, LPS-RK_SP, FNQ-R, FRS-R Fuse 250V LPN-RK_SP, FRN-R Fuse 2475V JCD 2750V JCX 2750/5500V JCW 5500V JCE, JCQ, JCY, JCU, 5.5 ABWNA, 5.5 AMWNA, 5.5 FFN 7200V 7.2 ABWNA, 7.2 SDLSJ, 7.2 SFLSJ 8300V JCZ, JDZ, 8.25 FFN 15500V JCN, JDN, JDM, 15.5 CAVH 17500V 17.5 CAV, 17.5 SDM 24000V 24 SDM, 24 SFM, 24 FFM 36000V 36 CAV, 36 SDQ, 36 SFQ 38000V 38 CAV Secondary 600V or below 250V: LPN-RK_SP, FRN-R 600V: LPS-RK_SP, FRS-R LPS-_SP, KRP-C_SP FNQ-R_ Fuse Technology Bussmann® Solenoids (Coils) Solid State Devices (Diodes, SCR-s, Triacs, Transistors) Mains Feeders Branches Motor Loads (N.E.C. 430) Based on 1996 N.E.C.® Supplementary Fuses Branch Circuit Fuses Short-Circuit Protection Only Main, Branch & Feeder Circuits (601-6000 Amps) Feeder Circuits (600 Amps & Less) 600V & Less Above 600V Motor Loads Size at 125% or next size larger. Size at 125% or next size smaller. 0-500 FNQ ⁄Ω¡º-30 0-250V MDL ⁄Ω¡§-8, MDA ¤Ω¡º-20, FNM ⁄Ω¡º-10, FNW 12-30, MDQ ⁄Ω¡ºº-7 0-125V MDA 25-30, FNM 12-15 0-32V MDL 9-30, FNM 20-30 251-600V LPS-RK_SP, FRS-R 0-600V LPJ_SP, LP-CC 0-250V LPN-RK_SP, FRN-R “F”, “S”, “K” & 170M Series fuses sized up to several sizes larger than full load RMS or DC rating of device. 150% to 225% of full load current of largest motor plus 100% of full load current of all other motors plus 125% of continuous non-motor load plus 100% of non-continuous non-motor load. *A max. of 175% (or the next standard size if 175% does not correspond to a standard size) is allowed for all but wound rotor and all D.C. motors. 150%* of the F.L.A. of largest motor (if there are two or more motors of same size, one is considered to be the largest) plus the sum of all the F.L.A. for all other motors. 150%* of the F.L.A. of largest motor (if there are two or more motors of same size, one is considered to be the largest) plus the sum of all the F.L.A. for all other motors plus 100% of non-continuous, non-motor load plus 125% of continuous, non-motor load. Combination Motor Loads and other Loads *150% for wound rotor and all DC motors. Max. of 300%* of motor F.L.A. or next size larger. If this will not allow motor to start due to higher than normal inrush currents or longer than normal acceleration times (5 sec. or greater), fuses through 600 amps may be sized up to 400% or next size smaller. 175%* of motor F.L.A. or next size larger. If this will not allow motor to start, due to higher than normal inrush currents or longer than normal acceleration times (5 sec. or greater), fuse may be sized up to 225% or next size smaller. 125% of motor F.L.A. or next size larger. 100% of non-continuous load plus 125% of continuous load. Short-Circuit Only Short-Circuit Only Backup Overload w/ Motor Starter & Short-Circuit Protection No Motor Load Protected by NonTime-Delay Fuses & all Class CC Fuses Protected by Time-Delay Fuses FUSE SIZED FOR: Compare the min. melting time-current characteristics of the fuses with the time-current characteristics of the overload relay curve. The size fuse which is selected should be such that short-circuit protection is provided by the fuse and overload protection is provided by the controller overload relays. 0-130V FWA 0-250V FWX 0-500V FWH 0-600V FWC, KAC, KBC 0-700V FWP, 170M Series, SPP 0-1000V FWJ, 170M Series, SPJ 0-600V KRP-C_SP 0-250V LPN-RK_SP, FRN-R 251-600V LPS-RK_SP, FRS-R 0-600V LPJ_ SP, LP-CC 0-250V LPN-RK_SP, FRN-R 0-300V JJN 251-600V LPS-RK_SP, FRS-R 301-600V JJS 0-600V JKS, LPJ_SP, KTK-R, LP-CC, LPT 0-250V LPN-RK_SP, FRN-R 251-600V LPS-RK_SP, FRS-R 0-600V LPJ_SP 0-250V KTN-R, NON 0-300V JJN 251-600V KTS-R, NOS 301-600V JJS 0-600V LP-CC, LPT, JKS, KTK-R 0-250V LPN-RK_SP, FRN-R 251-600V LPS-RK_SP, FRS-R Fuse 2400V JCK, JCK-A, JCH 4800V JCL, JCL-A, JCG 7200V JCR, 7.2 WKMSJ Fuse Diagnostic Chart Bussmann® 217 218 Capacitors (N.E.C. 460) Ballasts Electric Heat (N.E.C. 424) 250% to 300% of full load current Protected by Non-Time Delay Fuses Based on 1996 N.E.C.® 150% to 175% of full load current Protection recommended as shown below, but not required Mercury, Sodium, etc. All Other (Mercury, Sodium, etc.) Fluorescent 0-250V KTN-R, NON 0-300V JJN 251-600V KTS-R, NOS 0-600V JKS, KTK-R 301-600V JJS Fuse 0-250V LPN-RK_SP, FRN-R 251-600V LPS-RK_SP, FRS-R 0-600V FNQ-R, LPJ_SP, LP-CC Consult fixture manufacturer for size and type. Consult fixture manufacturer for size and type. Consult fixture manufacturer for size and type. BAF BAN KTK FNM FNQ FNW HEB HEX HPC-D HPF HPS HLR GLR GMF GRF BAF BAN KTK FNM FNQ FNW Holder Fuse Size at 125% or next size larger but in no case larger than 150 amperes for each subdivided load. Size at 125% or next size larger but in no case larger than 60 amperes for each subdivided load. Protected by Time-Delay Fuses On load side of motor running overcurrent device Outdoor Indoor Electric Boilers with Resistance Type Immersion Heating Elements in an ASME Rated and Stamped Vessel. Electric Space Heating KTK-R FNQ-R LP-CC KTQ BBS KTK-R FNQ-R LP-CC GLQ GMQ Fuse HEY HPS-L HPF-L HPS-RR HPF-RR HLQ Holder Holder HPF-EE HPS-EE HPF-JJ SC 20 HPS-JJ HPF-FF SC 25-30 HPS-FF SC -0-15 Fuse Fuse 0-250V LPN-RK_SP, FRN-R, NON 0-300V JJN 0-480V SC 251-600V LPS-RK_SP, FRS-R, NOS 301-600V JJS 0-600V LPJ_SP, LP-CC, FNQ-R, JKS, KTK-R Fuse Diagnostic Chart Bussmann® Time-Current & Current Limitation Curves Bussmann® TCF & TCFH CUBEFuseTM Fuses TCF & TCFH Time-Current Characteristic Curves– Average Melt 219 Bussmann® Time-Current & Current Limitation Curves KRP-C, Class L Fuses KRP-C Current Limitation Curves 4000A 5000A 6000A 1600A 2000A 2500A 3000A 1200A 800A KRP-C Time-Current Characteristic Curves— Average Melt AMPERE RATING 300 1000,000 B 6,000A 5,000A 4,000A 3,000A 2,500A 2,000A 1,600A 1,200A 800A 601A 100 AMPERE RATING 100,000 10 A PROSPECITVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPERES CURRENT IN AMPERES 220 200,000 100,000 1,000 .01 10,000 .1 300,000 100,000 1,000 10,000 1 1,000 TIME IN SECONDS 10,000 Bussmann® Time-Current & Current Limitation Curves LPN-RK (250V) Class RK1 Fuses AMPERE RATING LPN-RK_SP (250V) 300 15/100 2/10 3/10 4/10 1/2 8/10 6/10 1 1-1/4 1-6/10 2 2-1/2 3-2/10 4 5 6-1/4 8 10 12 600A 400A 200A 100A 60A 30A Time-Current Characteristic Curves—Average Melt 1/10 300 15A 20A Time-Current Characteristic Curves—Average Melt 100 AMPERE RATING LPN-RK_SP (250V) 10 TIME IN SECONDS TIME IN SECONDS 10 1 1 .1 1,000 100 1 .1 .01 10 .1 CURRENT IN AMPERES Current Limitation Curves B 400,000 AMPERE RATING LPN-RK_SP (250V) 100,000 600 400 200 100 60 10,000 30 200,000 100,000 1,000 10,000 A 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS RMS SYMMETRICAL CURRENT IN AMPERES 10,000 1,000 100 20 .01 RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) 221 Bussmann® Time-Current & Current Limitation Curves LPS-RK (600V) Class RK1 Fuses AMPERE RATING 300 4 5 8 10 12 LPS-RK (600V) 6-1/4 15/100 2/10 3/10 4/10 1/2 6/10 8/10 1 1-1/4 1-6/10 2 2-1/2 3-2/10 Time-Current Characteristic Curves—Average Melt 1/10 600A 400A 200A 100A 60A 30A 300 20A Time-Current Characteristic Curves—Average Melt AMPERE RATING 100 100 10 TIME IN SECONDS 1 1 1,000 1 .1 .01 .1 100 .1 10 TIME IN SECONDS 10 RMS SYMMETRICAL CURRENT IN AMPERES AMPERE RATING 100,000 600 400 200 100 60 10,000 30 200,000 100,000 A 10,000 20,000 LPS-RK (600V) 1,000 222 B 400,000 1,000 CURRENT IN AMPERES 10,000 1,000 100 30 .01 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Current Limitation Curves Bussmann® Time-Current & Current Limitation Curves FRN-R (250V) Class RK5 Fuses AMPERE RATING 300 FRN-R (250V) 15/100 2/10 3/10 4/10 1/2 8/10 6/10 1 1-1/4 1-6/10 2 2-1/2 3-2/10 4 5 6-1/4 8 10 12 Time-Current Characteristic Curves—Average Melt 1/10 600A 400A 200A 100A 60A 30A 300 15A Time-Current Characteristic Curves—Average Melt AMPERE RATING FRN-R (250V) 100 100 10 TIME IN SECONDS TIME IN SECONDS 10 1 1 .1 1,000 100 1 .1 .01 10 .1 CURRENT IN AMPERES AMPERE RATING FRN-R (250V) 100,000 600 400 200 100 60 10,000 30 100,000 10,000 1,000 1,000 A 200,000 20,000 B 400,000 INSTANTANEOUS PEAK LET-THRU CURRENT AMPERES CURRENT IN AMPERES 10,000 1,000 20 100 Current Limitation Curves .01 PROSPECTIVE SHORT CIRCUIT CURRENT SYMMETRICAL RMS AMPERES 223 Bussmann® Time-Current & Current Limitation Curves FRS-R (600V) Class RK5 Fuses Time-Current Characteristic Curves—Average Melt 300 1/10 15/100 2/10 3/10 4/10 1/2 6/10 8/10 1 1-1/4 1-6/10 2 2-1/2 3-2/10 4 5 6-1/4 8 10 12 Time-Current Characteristic Curves—Average Melt AMPERE RATING FRS-R (600V) 100 TIME IN SECONDS 10 1 1,000 100 1 .1 .01 10 .1 CURRENT IN AMPERES Current Limitation Curves B AMPERE RATING FRS-R (600V) 100,000 600 400 200 100 60 30 10,000 PROSPECTIVE SHORT CIRCUIT CURRENT SYMMETRICAL RMS AMPERES 224 200,000 100,000 1,000 10,000 A 1,000 INSTANTANEOUS PEAK LET THRU CURRENT AMPERES 400,000 Bussmann® Time-Current & Current Limitation Curves KTN-R (250V) Class RK1 Fuses Current Limitation Curves 10 1 AMPERE RATING 100 KTN-R (250V) 100,000 600 400 200 100 10,000 60 30 A 1,000 100,000 KTN-R (250V) 10,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 300 TIME IN SECONDS B 400,000 200,000 AMPERE RATING 1,000 600A 400A 200A 100A 60A 30A Time-Current Characteristic Curves—Average Melt RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) .1 10,000 1,000 100 40 .01 RMS SYMMETRICAL CURRENT IN AMPERES 225 Bussmann® Time-Current & Current Limitation Curves KTS-R (600V) Class RK1 Fuses AMPERE RATING 600 400 200 100 10,000 60 30 A 1,000 200,000 1 100,000 100,000 TIME IN SECONDS 10 KTS-R (600V) 10,000 100 B 400,000 1,000 200 Current Limitation Curves INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS CURRENT IN AMPERES 25 30 15 6 8 10 1 300 3 Time-Current Characteristic Curves—Average Melt RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) CURRENT IN AMPERES 226 200 100 20 10 2 1 .01 300 400 500 600 700 .1 Bussmann® Time-Current & Current Limitation Curves LPJ (600V), Class J Fuses .1 AMPERE RATING A 100 200,000 1 1,000 100,000 TIME IN SECONDS 10 10,000 10,000 100 600A 400A 200A 100A 60A 50A 40A 30A 20A 15A LPJ 1,000 LPJ B 100,000 100 AMPERE RATING INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 600A Current Limitation Curves 10A 15A 20A 30A 40A 50A 60A 100A 125A 200A 225A 400A 5A 3A 300 1A Time-Current Characteristic Curves— Average Melt 10,000 1,000 100 1 .01 10 PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPS RMS SYMMETRICAL CURRENT IN AMPERES 227 Bussmann® Time-Current & Current Limitation Curves JJN & JJS, Class T Fuses 400A 500A 800A 200A 100A 60A 15A 30A 10A 1A AMPERE RATING 5A Time-Current Characteristic Curves—Average Melt 3A 600A 400A 200A 100A 60A 30A 300 15A Time-Current Characteristic Curves—Average Melt AMPERE RATING 300 JJN (300V) JJS (600V) 100 100 TIME IN SECONDS 10 1 .1 1,000 1 10 .01 10,000 1 100 TIME IN SECONDS 10 CURRENT IN AMPERES 1,000 20 100 .01 10,000 .1 RMS SYMMETRICAL CURRENT IN AMPERES Current Limitation Curves 60 30 15 100,000 200,000 10,000 A 200 1,000 1,000 RMS SYMMETRICAL CURRENTS IN AMPERES A-B = ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS) 228 AMPERE RATING 400 200 100 60 30 10,000 1,000 A 200 200,000 10,000 1200 800 600 100,000 400 200 100 100,000 10,000 1200 800 600 JJS (600V) 1,000 100,000 B 400,000 100 AMPERE RATING JJN (300V) INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS B 400,000 100 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Current Limitation Curves RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) Bussmann® Time-Current & Current Limitation Curves LP-CC & FNQ-R Class CC Fuses FNQ-R-5 FNQ-R-7-1/2 FNQ-R-3 AMPERE RATING 200 FNQ-R-1 Time-Current Characteristic Curves—Average Melt FNQ-R-1/2 20 25 30 3 3⁄Ω™ 4 4⁄Ω™ 6 8 10 12 15 ⁄Ω™ flΩ¡º °Ω¡º 1 1⁄Ω¢ Time-Current Characteristic Curves—Average Melt AMPERE RATING 100 LP-CC 100 10 TIME IN SECONDS 1 200 300 400 500 100 10 1 0.01 .08 1000 CURRENT IN AMPERES 100 10 1 .01 1 .01 .1 .4 TIME IN SECONDS 10 CURRENT IN AMPERES 229 Time-Current & Current Limitation Curves KTK-R, Class CC Fuses 8A 10A 15A 20A 30A 5A 3A 2A 1A Time-Current Characteristic Curves—Average Melt AMPERE RATING 300 KTK-R 100 TIME IN SECONDS 10 1 RMS SYMMETRICAL CURRENT IN AMPERES 230 400 100 1 .01 10 .1 Bussmann® Bussmann® Glossary of Terms Ampere The measurement of intensity of rate of flow of electrons in an electric circuit. An ampere is the amount of current that will flow through a resistance of one ohm under a pressure of one volt. Ampere Rating The current-carrying capacity of a fuse. When a fuse is subjected to a current above its ampere rating, it will open the circuit after a predetermined period of time. Ampere Squared Seconds, l2t The measure of heat energy developed within a circuit during the fuse’s clearing. It can be expressed as “melting l2t”, “arcing l2t” or the sum of them as “Clearing l2t”. “l” stands for effective let-through current (RMS), which is squared, and “t” stands for time of opening, in seconds. Arcing Time The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared. Breaking Capacity (See Interrupting Rating) Cartridge Fuse A fuse consisting of a current responsive element inside a fuse tube with terminals on both ends. Class CC Fuses 600V, 200,000A interrupting rating, branch circuit fuses with overall dimensions of ⁄‹Ω£™∑ ≈ 1⁄Ω™∑. Their design incorporates a rejection feature that allows them to be inserted into rejection fuse holders and fuse blocks that reject all lower voltage, lower interrupting rating ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuses. They are available from ⁄Ω¡ºA through 30A. Class G Fuses 480V, 100,000A interrupting rating branch circuit fuses that are size rejecting to eliminate overfusing. The fuse diameter is ⁄‹Ω£™∑ while the length varies from 1fiΩ¡§∑ to 2⁄Ω¢∑. These are available in ratings from 1A through 60A. Class H Fuses 250V and 600V, 10,000A interrupting rating branch circuit fuses that may be renewable or non-renewable. These are available in ampere ratings of 1 amp through 600A. Class J Fuses These fuses are rated to interrupt a minimum of 200,000A ac. They are labelled as “Current-Limiting”, are rated for 600vac, and are not interchangeable with other classes. Class K Fuses These are fuses listed as K-1, K-5, or K-9 fuses. Each subclass has designated I2t and lp maximums. These are dimensionally the same as Class H fuses, and they can have interrupting ratings of 50,000, 100,000, or 200,000 A. These fuses are current-limiting. However, they are not marked “current-limiting” on their label since they do not have a rejection feature. Class L Fuses These fuses are rated for 601 through 6000A, and are rated to interrupt a minimum of 200,000A ac. They are labelled “CurrentLimiting” and are rated for 600Vac. They are intended to be bolted into their mountings and are not normally used in clips. Some Class L fuses have designed in time-delay features for all purpose use. Class R Fuses These are high performance fuses rated ⁄Ω¡º600A in 250V and 600V ratings. All are marked “Current Limiting” on their label and all have a minimum of 200,000A interrupting rating. They have identical outline dimensions with the Class H fuses but have a rejection feature which prevents the user from mounting a fuse of lesser capabilities (lower interrupting capacity) when used with special Class R Clips. Class R fuses will fit into either rejection or non-rejection clips. Class T Fuses An industry class of fuses in 300V and 600V ratings from 1 amp through 1200A. They are physically very small and can be applied where space is at a premium. They are fast acting and time-lag fuses, with an interrupting rating of 200,000A RMS. Classes of Fuses The industry has developed basic physical specifications and electrical performance requirements for fuses with voltage ratings of 600V or less. These are known as standards. If a type of fuse meets the requirements of a standard, it can fall into that class. Typical classes are K, RK1, RK5, G, L, H, T, CC, and J. Clearing Time The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent protective device. Clearing time is the total of the melting time and the arcing time. Current Limitation A fuse operation relating to short circuits only. When a fuse operates in its current-limiting range, it will clear a short circuit in less than ⁄Ω™ cycle. Also, it will limit the instantaneous peak let-through current to a value substantially less than that obtainable in the same circuit if that fuse were replaced with a solid conductor of equal impedance. Dual Element Fuse Fuse with a special design that utilizes two individual elements in series inside the fuse tube. One element, the spring actuated trigger assembly, operates on overloads up to 5-6 times the fuse current rating. The other element, the short circuit section, operates on short circuits up to their interrupting rating. Electrical Load That part of the electrical system which actually uses the energy or does the work required. Fast Acting Fuse A fuse which opens on overload and short circuits very quickly. This type of fuse is not designed to withstand temporary overload currents associated with some electrical loads. Fuse An overcurrent protective device with a fusible link that operates and opens the circuit on an overcurrent condition. High Speed Fuses Fuses with no intentional time-delay in the overload range and designed to open as quickly as possible in the short-circuit range. These fuses are often used to protect solidstate devices. Inductive Load An electrical load which pulls a large amount of current—an inrush current—when first energized. After a few cycles or seconds the current “settles down” to the full-load running current. Interrupting Capacity See Interrupting Rating Interrupting Rating (Breaking Capacity) The rating which defines a fuse’s ability to safely interrupt and clear short circuits. This rating is much greater than the ampere rating of a fuse. The NEC® defines Interrupting Rating as “The highest current at rated voltage that an overcurrent protective device is intended to interrupt under standard test conditions.” Melting Time The amount of time required to melt the fuse link during a specified overcurrent. (See Arcing Time and Clearing Time.) “NEC” Dimensions These are dimensions once referenced in the National Electrical Code. They are common to Class H and K fuses and provide interchangeability between manufacturers for fuses and fusible equipment of given ampere and voltage ratings. Ohm The unit of measure for electric resistance. An ohm is the amount of resistance that will allow one ampere to flow under a pressure of one volt. 231 Bussmann® Glossary of Terms Ohm’s Law The relationship between voltage, current, and resistance, expressed by the equation E = IR, where E is the voltage in volts, I is the current in amperes, and R is the resistance in ohms. One Time Fuses Generic term used to describe a Class H nonrenewable cartridge fuse, with a single element. Overcurrent A condition which exists on an electrical circuit when the normal load current is exceeded. Overcurrents take on two separate characteristics—overloads and short circuits. Overload Can be classified as an overcurrent which exceeds the normal full load current of a circuit. Also characteristic of this type of overcurrent is that it does not leave the normal current carrying path of the circuit—that is, it flows from the source, through the conductors, through the load, back through the conductors, to the source again. Peak Let-Through Current, lp The instantaneous value of peak current letthrough by a current-limiting fuse, when it operates in its current-limiting range. Renewable Fuse (600V & below) A fuse in which the element, typically a zinc link, may be replaced after the fuse has opened, and then reused. Renewable fuses are made to Class H standards. Resistive Load An electrical load which is characteristic of not having any significant inrush current. When a resistive load is energized, the current rises instantly to its steady-state value, without first rising to a higher value. 232 R.M.S. Current The R.M.S. (root-mean-square) value of any periodic current is equal to the value of the direct current which, flowing through a resistance, produces the same heating effect in the resistance as the periodic current does. Semiconductor Fuses Fuses used to protect solid-state devices. See “High Speed Fuses”. Short Circuit Can be classified as an overcurrent which exceeds the normal full load current of a circuit by a factor many times (tens, hundreds or thousands greater). Also characteristic of this type of overcurrent is that it leaves the normal current carrying path of the circuit—it takes a “short cut” around the load and back to the source. Short-Circuit Rating The maximum short-circuit current an electrical component can sustain without the occurrence of excessive damage when protected with an overcurrent protective device. Short-Circuit Withstand Rating Same definition as short-circuit rating. Single Phasing That condition which occurs when one phase of a three phase system opens, either in a low voltage (secondary) or high voltage (primary) distribution system. Primary or secondary single phasing can be caused by any number of events. This condition results in unbalanced currents in polyphase motors and unless protective measures are taken, causes overheating and failure. Threshold Current The symmetrical RMS available current at the threshold of the current-limiting range, where the fuse becomes current-limiting when tested to the industry standard. This value can be read off of a peak let-through chart where the fuse curve intersects the A-B line. A threshold ratio is the relationship of the threshold current to the fuse’s continuous current rating. Time-Delay Fuse A fuse with a built-in delay that allows temporary and harmless inrush currents to pass without opening, but is so designed to open on sustained overloads and short circuits. Voltage Rating The maximum open circuit voltage in which a fuse can be used, yet safely interrupt an overcurrent. Exceeding the voltage rating of a fuse impairs its ability to clear an overload or short circuit safely. Withstand Rating The maximum current that an unprotected electrical component can sustain for a specified period of time without the occurrence of extensive damage. Bussmann® Index by Part Number Catalog Symbol Page AAO 196 ABC 34 ABCNA 170 ABFNA 170 ABGNA 170 ABWNA 170 AC 197 AD 197 ADLSJ 169 ADOSJ 169 AGA 32 AGC 34 AGU 36 AGW 32 AGX 32 AMWNA 170 ANL 38 ANN 38 ATC 40 ATM 40 BAF 24 BAN 24 BAO 196 BBS 23 BBU 157-158 BC 197 BC6031 64 BC6032 64 BC6033 64 BCCM 64 BD 197 BDAUX 112 BDH 101-102, 104, 109, 111, 114 BDNF 107, 111 BDS 102, 104, 105, 111 BDST 102 BDTA 103, 105 BDTL 103, 104, 105, 112 BDTS 112 BDZX 112 BG 64 BG3011 64 BG3012 64 BG3013 64 BG3021 64 BG3022 64 BG3023 64 BG3031 64 BG3032 64 BG3033 64 BH-0_ _ _ 67, 130, 147 BH-1_ _ _ 67, 130, 147 BH-2_ _ _ 67, 130, 147 BH-3_ _ _ 67, 130, 147 BM 64 BM6031 64 BM6032 64 BM6033 64 BNQ21-WH 93 BP/AGX 208 BP/GLH 208 BP/MAS 208 BP/XMAS 208 BQQ41-WH 93 C30F 199 Catalog Symbol Page Catalog Symbol Page C515 29 C517 29 C518 29 C519 29 C520 29 C5268 130, 150 C60F 199 CAV 170 CAVH 170 CD 197 CDAUX 103 CDBY 109 CDH 100, 102, 108, 110, 114 CDHX 101-102, 109, 111 CDHXB 104, 114 CDHXY 104, 114 CDHZX 110 CDMC 109 CDN 189 CDNF 106, 108, 110 CDS 100-101, 108-109, 186 CDSWM 109 CEO 196 CFC 103 CFD 99, 100, 101, 103, 102 CFTS 103 CFZ 103 CGL 190 CH 65 CIF06 191 CIF21 191 CIH 194 CIK 194 CIL 194 CJ 192 CM_ _CF 194 CS/XMAS 2048 CT 149 DD 197 DEO 196 DIN 132-138 DLN-R 14 DLS-R 14 ECL055 159 ECL155 160 ED 197 EDA 27 EET 149-150 EF 1937 EFC 113-116 EFJ 113-116 EFL 113-114, 116 EFS 197 EK 191 ENA 27 ENF 117-120 ERK-28 206 ESD 196 ET 149-150 FD 99, 104 FDM 209 FE 149-150 FEE 149-150 FF 197 FG 197 FL11H_ _ FL11K_ _ FL11T_ _ FM FMM FNA FNM FNQ FNQ-R FP FR-1000 FRN-R FRS-R FSD FT FWA FWC FWH FWJ FWK FWL FWP FWS FWX G GBA GBB GDA GDB GDC GF GG GH GLD GLQ GLR GMA GMC GMD GMF GMQ GMT GRF H07C H25_ _ _ H60_ _ _ HBH HBV HBW HEB HEC HEG HEH HEJ HET HEX HEY HFA HFB HHB HHC HHD HHF HHG HHL 173 173 173 149-150 149-150 37 25 25 22 202 205 12, 205 13, 205 209 202 124, 151 153 33, 126, 152 129, 155 154 155 128, 153-154 155 125, 152 64 37 35 30 30 30 197 197 197 37 39 39 31 31 31 39 39 186 39 194 47 48 70 70 70 80, 81 80 80 80 80 80 80 80 77 76 76 82 82 82 82 82 Catalog Symbol HHM HHT HHX HJL HK HKL HKP HKR HKT HKU HKX HLD HLQ HLR HLS HLT HM HME HMF HMG HMH HMI HMJ HPC-D HPD HPF HPG HPM HPS HPS2 HR HRC HRE HRF HRG HRH HRI HRJ HRK HTB HTC-140M HTC-15M HTC-200M HTC-210M HTC-30M HTC-35M HTC-40M HTC-45M HTC-50M HTC-55M HTC-60M HTC-65M HTC-70M HVA HVB HVJ HVL HVR HVT HVU HVW HVX IBS J-_ _ J60030 Page 87 77 82 75 75 75 72 75 75 75 75 75 39 39 186 186 77 77 77 77 77 77 77 79 78 78 78 79 78 79 77 195, 199 77 77 77 77 77 77 76 73, 74 85 85 85 85 71 71 71 69 69 71 69 69 71 171 171 171 171 171 171 171 171 171 150 203 53, 54 Catalog Symbol J60060 J60100 J60200 J60400 J60600 J70100 JCD JCE JCG JCH JCI JCK JCL JCQ JCR JCT JCU JCW JCX JCY JCZ JDZ JJN JJS JKS JP60030 JT(N)60030 JT(N)60060 K K07C KAC KAZ KBC KCA KCB KCC KCD KCE KCF KCH KCJ KCM KCR KCS KCY KCZ KDA KDB KDC KDD KDE KDF KDH KDJ KDM KDP KDR KDT KDY KEW KEX KFH-A KFM KFT KFZ Page 53, 53, 53, 53, 53, 54 54 54 54 54 56 166 166 161, 163 161, 162 166 162, 162 161, 162, 163 166 161, 163 166 168 166 167 167 168 168 19 19 18 55 57, 58 57, 58 28 194 127 38 127 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 233 Bussmann® Index by Part Number Catalog Symbol KIG KLM KLU KPF KQO KQT KQV KRP-CL KRP-C_SP KT3 KT4 KTK KTK-R KTN-R KTQ KTS-R KTU L09C L14C LBS LCT LET LMMT LMT LP-CC LPJ_SP LPN-RK_SP LPRK-28 LPS-RK_SP M09C M14C MAX MDA MDL MDQ MIC MIN MIS MMT MT MV055 MV155 N512 NC3 NDN NDN1 NDN111 NDN3 NDN63 NDNA NDNAS NDNF1 NDNLFD1 NDNV4 NFT2 NFT3 NFTA NH_G NH_G-690 NH_M NITD NNB NNB-R NNC No. 1 234 Page 28 24 8 28 28 28 28 7 6 92 92 24 22 15 23 15 8 195 195 201 148 148, 150 148, 150 148, 150 21 17 9 20 9 195 195 40 36 35 36 37 37 38 149 149 165 165 91 91 91 90 90 89 89 90, 103 91 94 94 89 91 91 91 200 200 200 196 203 203 203 2004 Catalog Symbol Page Catalog Symbol No. 140 No. 2 No. 200 No. 201 No. 205 No. 213 No. 216 No. 220 No. 226 No. 242 No. 2621 No. 263 No. 2641 No. 2642 No. 2661 No. 2662 No. 2664 No. 270 No. 2880 No. 36 No. 4 No. 5 No. 6 No. 626 No. 7 No. 8 No.15 NON NOS NRA NSD NSE3 NSS3 NTN-R NTQ23-WH NTS-R NZ_ _ _ OEFMA OEGMA OHFMA OHGMA OLGMA OPM-1038 OPM-NG-SC3 OPM-NG-SM3 OPM-SW OPMRH OSD P09C P11C PCT PFD-948 PLK3 PLU1 PLU3 PMP PON PS PSU1 R11C R25030 R25060 R25100 R25200 R25400 207 204 208 208 208 203 203 207 203 203 203 203 203 203 203 203 203 207 208 206 204 204 204 203 204 204 205 16 16 91 196 91 91 203 94 203 198 172 172 172 172 172 44 41, 42 41, 42 45 109 196 195 195 187 205 92 92 92 122 189 122 92 195 48, 49 48, 49 48, 49 48, 49 48, 49 R25600 R60030 R60060 R60100 R60200 R60400 R60600 S S-8001 SA SAMI SB SC SCY SDLSJ SDMSJ SDQSJ SFC SFLSJ SFMSJ SFQSJ SKA SKLSJ SKMSJ SL SOA72 SOU SOW SOX SOY SOY-B SRU SRW SRX SRY SSD SSU SSW SSX SSY SSY-L SSY-RL STD STY T T30030 T30060 T30100 T30200 T60030 T60060 T60100 T60200 T60400 T60600 TB TCF TCFH TDC10 TDC11 TDC180 TDC600 TL TP158HC TP15900-4 47, 47, 47, 47, 47, Page 47, 50, 50, 50, 50, 50, 50, 48, 51, 51, 51, 51, 51, 51, 49 52 52 52 52 52 52 26 83 27 46 201 20 68 169 169 169 202 169 169 169 68 169 169 26 91 68 68 68 68 68 68 68 68 68 196 68 68 68 68 68 68 196 68 26 59, 60 59, 60 59, 60 59, 60 61, 62 61, 62 61, 62 61, 62 61, 62 61, 62 1201 4 4 34 35 33 33 26 180 178 Catalog Symbol TP15914 TPA TPA-B TPC &TPCDS TPHCS TPL TPC &TPCDS TPN TPS TPSFH TYPE D (_D_ _) VFNHA VKNHA VLB W WDFHO WDLSJ WDOH6 WDOSJ WER WFFHO WFLSJ WFMSJ WFNHO WFOH6 WJON6 WKFHO WKLSJ WKMSJ WKNHO 11 Type 11239 11240 11241 11242 11675 11725 14002 14004 15087 15100 15149 15200 15800 160_ _ _ 162_ _ _ 163_ _ _ 165_ _ _ 170H_ _ _ _ 170M_ _ _ _ 1A1119 1A1120 1A1907 1A3398 1A3399 1A3400 1A4533 1A4534 1A5018 1A5600 1A5601 1A5602 1BS 24 Type 2499 Page 177 178 178 175 182 183 176 184 179 202 198 164 164 201 26 164 164, 169 164 169 187 164 164, 169 164 164 164 164 164 169 164, 169 164 187 63 63 63 63 95 95 95 95 185 178 121 178 177 96 96 96, 97, 98 96, 97 146-147 132-145 86 86 86 86 85 87 86 86 85 87 85 85 147 187 83 Catalog Symbol Page 2601 2602 2604 2605 2607 2608 2610 2611 2960 2NZ01 3723 3742 3743 3828 3835 4393 4421 4515 4520 4528 4529 4530 4574 4NZ01 5591 5592 5672 5674 5681 5682 5956 5960 5TPH 6NZ01 64000 64200 64300 64400 64600 68000 68150 68200 68300 68400 68600 7 Type 70 Series 74 Type 75 Type 76 Type 8000 80 Type 81 Type 63 63 63 63 63 63 63 63 171 198 66 66 66 84 66 84 66 66 84 171 171 171 83 198 88 88 88 88 88 88 88 88 202 197 28 28 28 28 28 28 28 28 28 28 28 187 185 188 188 188 83 188 187 Printed with Recyclable Paper using Soy Ink Bussmann ® Worldwide Circuit Protection Solutions HEADQUARTERS Cooper Industries Bussmann Division P. O. Box 14460 St. Louis, Missouri 63178-4460, USA Telephone: 636 394 2877 Fax: 800 544 2570 International: 636 527 1413 Email: fusebox@buss.com COOPER BUSSMANN CHICAGO 175 Hansen Court Wood Dale, IL 60191 Telephone: 630 422 2400 Fax: 630 422 2500 EUROPEAN HEADQUARTERS Cooper (UK) Ltd. Bussmann Division Burton-on-the-Wolds Leicestershire LE12 5th, England Telephone: 44 1509 882737 Fax: 44 1509 882786 Email: info@bussmann.co.uk BUSSMANN ASIA-PACIFIC 1 Jalan Kilang Timor #06-01 Pacific Tech Centre Singapore 159303 Republic of Singapore Telephone: 65 278 6151 Fax: 65 278 3151 Email: bussmann@bussasiapac.com.sg BUSSMANN AUSTRALIA Block X 391 Park Road PO Box 257 Regents Park, Sydney NSW 2143, Australia Telephone: 61 2 9743 8333 Fax: 61 2 9743 8070 BUSSMANN BRASIL Bussmann do Brasil Ltda. Rodovia Santos Dumont, Km 23 Cruz das Almas Itu - Sao Paulo- 13 300-000 Brasil Telephone: 55 11 7824 1856 Fax: 55 11 7824 1721 BUSSMANN DENMARK 5 Literbuen DK-2740 Skovlunde Copenhagen, Denmark Telephone: 45 4485 0900 Fax: 45 4485 0901 Email: bussmann@bussmann.dk BUSSMANN INDIA 2nd floor, Unit #5 White House 23-29, St. Marks Road Bangalore — 560 001 India Telephone: 91 80 227 0893 Fax: 91 80 224 0124 BUSSMANN MEXICO Arrow-Hart, S.A. de C.V. Poniente 148, No. 933 02300 Mexico, D.F. Mexico Telephone: 52 5 587 0211 Fax: 52 5 567 4049 COOPER ELECTRONIC TECHNOLOGIES, INC. 6000 Park of Commerce Blvd Boca Raton, Fl 33487 Tel: 561 241 7876 Fax: 561 241 9339 ENBRAY CONTACTORS Cooper (UK) Limited Unit 5C, Clay Flatts Industrial Estate Workington, Cumbria CA14 3YD United Kingdom Tel : +44 0 1900 870088 Fax : +44 0 1900 870099 COOPER BUSSMANN • P.O. BOX 14460 • ST. LOUIS, MO 63178-4460 • (636) 394-2877 World Wide Web: www.bussmann.com REORDER #1007 10-02-50M CUBEFuse™ The World’s First “Finger-Safe” Industrial Fuse. Finger-Safe Test Points 30-Amp Fuses Plug Into 60-Amp Fuseholders Class J TimeDelay Electrical Performance Permanent “OpenFuse” Indication • • • Finger-Safe Fuse, Fuseholder, and Wire Ports (IP-20) • Dovetail Fuseholder Design for Ganging 30Amp and 60-Amp Poles • • • • • Smaller Footprint Than Class J and Class CC Wire Ports Can Accept Dual Wires REORDER #1007 Fuseholder Mounted by 35mm DIN Rail or by Standard Hardware ©2002, Cooper Bussmann, Inc. • St. Louis, MO 63178 • 636-394-2877 www.bussmann.com www.cubefuse.com 10-02-40M
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 240 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:8e0272ab-49e3-4e71-8433-dda4e8b8e95b Producer : Acrobat Distiller 4.05 for Macintosh Modify Date : 2008:11:25 15:38:23-06:00 Create Date : 2002:11:19 09:11:24Z Metadata Date : 2008:11:25 15:38:23-06:00 Document ID : uuid:ba7c6d2c-62ed-4c38-a8bf-88e29cbba000 Format : application/pdfEXIF Metadata provided by EXIF.tools