Bussmann

®

Circuit Protection Solutions

Bussmann

®

Worldwide Circuit Protection Solutions

World’s leading supplier of fuses and fusible protection
systems, Bussmann continues its 88-year history of blazing new
trails of innovative technologies. Maker of the industry’s first
truly global product line, each item is backed by an efficient
worldwide network of distribution, customer service and
technical support. Bussmann products include the most
extensive circuit protection solutions approved for use in
a variety of major standards: UL, CSA, IEC. . . Not to
mention both European (DIN, British Standard) and
North American styled fuses for a wide range of
applications: industrial motor protection, power
conversion, medium voltage, power distribution,
telecommunications network equipment, electronics,
and automotive. Manufacturing operations in the U.S.,
Denmark, and the United Kingdom have earned ISO
9000 certification. Bussmann customers are assured
of only the utmost quality across every product line.
Knowledgeable. Responsive. Customer focused.
Bussmann continues to set the standard for circuit
protection solutions around the world.

This catalog is intended to present product data and provide technical information that will
help the end user with design application. Bussmann reserves the right, without notice,
to change design or construction of any products and to discontinue or limit distribution
of any products. Bussmann also reserves the right to change or update, without notice,
any technical information contained in this catalog. Once a product has been selected, it
should be tested by the user in all possible applications.
©2002 Cooper Bussmann
Printed in the U.S.A.

®

Bussmann

Section Guide
Page

1

Electrical – Power Fuses

1

2

Electronic – PC Board and Small Dimension Fuses

29

3

Fuseblocks and Holders

41

4

Disconnect Switches

99

5

High Speed Fuses

123

6

Medium Voltage Fuses and Fuse Links

157

7

Telecommunications Protection

175

8

British, European, & Canadian Standard Industrial Fuses

189

9

Fuse Accessories, Displays, Kits, Etc.

202

10

Fuse Technology

210

Glossary of Terms
Index

231
233

Now you can get current information about Bussmann products at anytime,
using BIF (Bussmann Information FAX) or visit us on the World Wide Web.

Bussmann
Information Fax ~
636.527.1450
Bussmann
Worldwide Web ~

BIF is a simple to use automated fax response system. All you need is a touchtone telephone and a fax machine to get complete product specifications when
you want it. Data sheet numbers are located throughout this catalog. To get a
detailed data sheet on the product of your choice, simply dial 636-527-1450
and request the document number listed. In a matter of minutes a data sheet
will be faxed to you. It’s that simple.
Data sheets can also be downloaded from the Internet. The Bussmann web site
is continuously updated with our newest products and latest data on circuit protection solutions. Visit us often at http://www.bussmann.com

http://www.bussmann.com

©2002 Cooper Bussmann

Printed in U.S.A.
i

®

Bussmann

Table of Contents
Electrical - Power Fuses

Disconnect Switches

General Data (Selection Guide, Dimensional Data) . . . . . . .1-3
Cubefuse (TCF & TCFH) . . . . . . . . . . . . . . . . . . . . . . . . .4-5
Class L Fuses (KRP-C_SP, KTU, KLU) . . . . . . . . . . . . . . .6-8
Class RK1 Fuses
(LPN-RK_SP, LPS-RK_SP, KTN-R, KTS-R) . . . . . .9-11, 15
Class RK5 Fuses (FRN-R, FRS-R, DLN-R, DLS-R) . . . .12-14
One-Time Fuses (NON, NOS) . . . . . . . . . . . . . . . . . . . . . .16
Class J Fuses (LPJ_SP, JKS) . . . . . . . . . . . . . . . . . . . .17-18
Class T Fuses (JJN, JJS) . . . . . . . . . . . . . . . . . . . . . . . . .19
Class G Fuses (SC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Class CC Fuses (LP-CC, FNQ-R, KTK-R) . . . . . . . . . . .21-22
Supplementary Fuses (Midget fuses ⁄‹Ω£™∑ diameter) . . . .23-25
Plug Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26-27
Cable Limiters and Welder Limiters . . . . . . . . . . . . . . . . . .28

Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99-105, 121
Non-Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . .106-112
Fusible, Enclosed . . . . . . . . . . . . . . . . . . . . . . . .113-116
Non Fusible, Enclosed . . . . . . . . . . . . . . . . . . . .117-120
Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122

Electronic Fuses
PC Board and Small Dimension
5mm x 15mm Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
5mm x 20mm Fuses . . . . . . . . . . . . . . . . . . . . . . . . . .30-31
⁄Ω¢∑ Diameter Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . .32-36
Pin Indicating Type Fuses . . . . . . . . . . . . . . . . . . . . . . .37-38
Actuators and Limiters . . . . . . . . . . . . . . . . . . . . . . . . . . .38
In-Line Fuses/Fuseholders . . . . . . . . . . . . . . . . . . . . . . . .39
Blade-Type Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

Fuseblocks, Holders and Terminal
Blocks
Overcurrent Protection Modules . . . . . . . . . . . . . . . . . .41-45
Fuse Covers . . . . . . . . . . . . . . . . . . . . . . . . . .46 Fuseblocks
Class H, K, and R . . . . . . . . . . . . . . . . . . . . . . .47-52, 63
Class J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53-55, 63
Semiconductor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Class J (Touch Safe) . . . . . . . . . . . . . . . . . . . . . . . .57-58
Class T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59-62
Class CC, G and Type M . . . . . . . . . . . . . . . . . . . . . . .64
for ⁄Ω¢∑ and ⁄‹Ω£™∑ Diameter Fuses . . . . . . . . .66, 83-84, 86
for 5mm Diameter Fuses . . . . . . . . . . . . . . . . . . . . . . .85
Modular Fuseblocks and Fuseholders . . . . . . . . . . . . .65, 67
Box Cover Units for Plug Fuses . . . . . . . . . . . . . . . . . . . . .68
PC Board Mount Fuseholders . . . . . . . . . . . . . . . . . . .69-70
Panel Mount Fuseholders . . . . . . . . . . . . . . . . .71-75, 78-79
In-Line Fuseholders . . . . . . . . . . . . . . . . . . . . .76-77, 80-82
PC Board Fuseclips . . . . . . . . . . . . . . . . . . . . . . . . . . .87-88
Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89-93
Rail Mount Fuseholders . . . . . . . . . . . . . . . . . . . . . . . . . .94
Power Distribution Blocks . . . . . . . . . . . . . . . . . . . . . .95-97

High Speed Fuses
North American Style . . . . . .
European Style Square Body
British Standard BS88 . . . . .
Ferrule Style . . . . . . . . . . . .

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.123-130
.131-147
.148-150
.151-158

Medium Voltage Fuses
BBU Boric Acid Fuse . . . . . . . . . . . . . . . . . . . . . . . .157-158
R-Rated Fuses (Motor Circuit Protection) . . . . . . . . .161-164
E-Rated Fuses (Transformers Protection) . .159-160, 165-168
DIN Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
Potential Transformer Fuses . . . . . . . . . . . . . . . . . . . . . .170
Medium Volt, Fast Acting . . . . . . . . . . . . . . . . . . . . . . . .171
BS2692-1 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172
Fuse Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173

Telecommunications
Fused Disconnect Switch
Telpower Fuses . . . . . . . .
Indicating Fuses & Holders
Specialty Fuses . . . . . . . .

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.175-181
.182-184
.185-186
.187-188

British, European, & Canadian
Standard Industrial Fuses
CSA Type P and D Fuses . . . . . . . . . . . . . . . . . . . . . . . .190
HRC Industrial Fuses . . . . . . . . . . . . . . . . . . . . . . . .191-195
BS88 Low Voltage Industrial Fuses . . . . . . . . . . . . . .196-197
DIN Style Type D and Neozed Fuses . . . . . . . . . . . . . . . .198
HRC Fuseholders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
NH Fuse System . . . . . . . . . . . . . . . . . . . . . . . . . .200-201

Fuse Accessories, Displays,
Kits, Etc.
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202-204
Display Racks and Service Kits . . . . . . . . . . . . . . . .205-209

Fuse Technology
Fuseology . . . . . . . . . . . . . . . . . . . . . . .
Fuse Diagnostic Chart . . . . . . . . . . . . . .
Time-Current & Current Limitation Curves
Glossary of Terms . . . . . . . . . . . . . . . . .

Index
ii

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.210-215
.216-218
.219-230
.231-232

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233-234

®

General Data — Selection Chart

Bussmann

Buss Fuse Selection Chart (600 Volts or Less)
Circuit

Load

Ampere Fuse
Rating Type

Symbol

Voltage
Rating (a-c)

Class

Interrupting
Rating
(KA)

Remarks

All-purpose fuses.
Unequaled for combined
short-circuit and
overload protection.
(Specification grade product)

Page

Conventional Dimensions—Class RK1, RK5 (0-600A), L (601-6000A)

200,000A or 300,000A Interrupting Rating (rms symmetrical)
Current Limiting

All type loads
(optimum
overcurrent
protection).
Motors, welder,
transformers,
capacitor banks
(circuits with heavy
inrush currents).

Main,
Feeder
and
Branch

LOW-PEAK®
(dual-element,
time-delay)

LPN-RK_SP
LPS-RK_SP

250V
600V

RK1††

300

601 to
6000A

LOW-PEAK®
(time-delay)

KRP-C_SP

600V

L

300

0
to
600A

FUSETRON®
(dual-element,
time-delay)

FRN-R
FRS-R

250V
600V

RK5††

200

0
to
600A

DURA-LAGTM
(dual-element,
time-delay)

DLN-R
DLS-R

250V
600V

RK5

200

601 to
4000A

LIMITRON®
(time-delay)

KLU

600V

L

200

All-purpose fuse. Timedelay passes surge-currents.

8

KTN-R
KTS-R

250V
600V

RK1††

200

Same short-circuit protection
as LOW-PEAK fuses but
must be sized larger for
circuits with surge-currents;
i.e., up to 300%.

15

KTU

600V

L

200

A fast acting, high
performance fuse.

8

Non-motor loads
(circuits with no
0
heavy inrush
to
currents).
600A
LIMITRON fuses
_____
particularly suited for 601 to
circuit breaker
6000A
protection.

LIMITRON®
(fast-acting)

Moderate degree of
current limitation. Time-delay
passes surge currents.

9-11

6-7
12
13
14

Reduced Dimensions For Installation in Restricted Space—Class J(0-600A), T(0-1200A), CC(0-30A), G(0-60A)
All type loads
(optimum
overcurrent
protection).

__________
Non-motor loads
(circuits with no
heavy inrush
currents).

Branch

10,000–50,000 AIC

0-600A

General
Purpose
(noncurrent
limiting
fuses)

0
to
600A
0 to
1200A

LOW-PEAK®
(dual-element
time-delay)

LPJ_SP

600V

J

300

All-purpose fuses.
Unequaled for combined
short-circuit and overload
protection. (Specification
grade product)

17

LIMITRON®
(quick acting)

JKS

600V

J

200

Very similar to KTS-R
LIMITRON, but smaller.

18

T-TRONTM

JJN
JJS

300V
600V

T

200

The space saver (⁄Ω£ the size
of KTN-R/KTS-R).

19

Motor loads
(circuits with
heavy in-rush
currents.)

0 to 30A LOW-PEAK®
(time-delay)

LP-CC

600V

CC

200

Rejection feature

21

Non-motor loads
(circuits with no
heavy in-rush
currents.)

0 to 30A LIMITRON®
(fast-acting)

KTK-R

600V

CC

200

Very compact (⁄‹Ω£™∑ ≈ 1⁄Ω™∑);
rejection feature.

22

Control transformer
circuits and lighting
ballasts; etc.

0 to 30A TRON®
(time-delay)

FNQ-R

600V

CC

200

Excellent for control
transformer protection.

22

General purpose;
i.e., lighting
panel boards.

1 to 20A SC

SC

600V

G

100

Current limiting;
⁄‹Ω£™∑ dia. ≈ varying
lengths per amp rating.

20

25 to 60A

480V

Miscellaneous

0 to
600A

ONE-TIME

NON
NOS

250V
600V

H or K5† 10

Forerunners of
the modern

16

Plug fuses can
be used for
branch circuits
and small
component
protection.

0
to
30A

FUSTAT®
(dual-element,
time-delay)
FUSETRON®
(dual-element,
time-delay)

S

125V

S

10

26

T

125V

**

10

Buss Type W

W

Base threads of Type S
differ with amp ratings.
T and W have Edison base.
T & S fuses recommended
for motor circuits. W not
recommended for circuits
with motor loads.

125V

**

10

26

** UL Listed as Edison Base Plug Fuse.
† Some ampere ratings are available as UL Class K5 with a 50,000A interrupting rating.
†† RK1 and RK5 fuses fit standard switches, fuseblocks and holders; however, the rejection feature of class R switches and fuseblocks designed specifically for rejection type fuses
(RK1 and RK5) prevent the insertion of the non-rejection fuses (K1, K5, and H).

1

®

Bussmann

General Data – Dimensions (Inches)
CLASS T

CLASS J

CLASS RK5 & RK1

T-Tron™ Fuses
JJN (300V)
JJS (600V)

Low-Peak® & Limitron® Fuses
LPJ & JKS (600V)

Fusetron®, Low-Peak® &
Limitron® Fuses (250V & 600V)
FRN-R & FRS-R; LPN-RK &
LPS-RK; KTN-R & KTS-R
Basic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and
SUPERLAG Renewable RES & REN fuses.
NOTE: These fuses can be used to replace
existing Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
A
B

250V
Ampere
⁄Ω¡º-30
35-60

A
2∑
3∑

600V
B
.56∑
.81∑

A
5∑
5.5∑

B
.81∑
1.06∑

A
B

Fusetron & Limitron

250V
Ampere
70-100
110-200
225-400
450-600

A
5.88∑
7.13∑
8.63∑
10.38∑

B
1.06∑
1.56∑
2.06∑
2.59∑

600V
A
7.88∑
9.63∑
11.63∑
13.38∑

B
1.34∑
1.84∑
2.59∑
3.13∑

Low-Peak

250V
Ampere
70-100
110-200
225-400
450-600

A
5.88∑
7.13∑
8.63∑
10.38∑

B
1.16∑
1.66∑
2.38∑
2.88∑

600V
A
7.88∑
9.63∑
11.63∑
13.38∑

B
1.16∑
1.66∑
2.38∑
2.88∑

CLASS L Low-Peak® & Limitron® Fuses
KRP-C, KTU, & KLU (601 - 6000A) (600V)
NOTE: KRP-CL (150A to 600A) fuses
have same dimensions as 601A to
800A case size. KTU (200A to 600A)
have same dimensions, except tube
3∑ lgth. ≈ 2∑ dia.; terminal 1fi/•∑ width
≈ 1⁄/¢∑ thick.

2

®

Bussmann

General Data – Dimensions (Millimeters)
CLASS T

CLASS J

CLASS RK5 & RK1

T-Tron™ Fuses
JJN (300V)
JJS (600V)

Low-Peak® & Limitron® Fuses
LPJ & JKS (600V)

Fusetron®, Low-Peak® &
Limitron® Fuses (250V & 600V)
FRN-R & FRS-R; LPN-RK &
LPS-RK; KTN-R & KTS-R
Basic dimensions are same as Class H (formerly NEC) ONE-TIME (NON & NOS) and
SUPERLAG Renewable RES & REN fuses.
NOTE: These fuses can be used to replace
existing Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
A
B

250V
Ampere
⁄Ω¡º-30
35-60

A
50.8
76.2

B
14.3
20.6

600V
A
127.0
139.7

B
20.6
27.0

A
B

Fusetron & Limitron

250V
Ampere
70-100
110-200
225-400
450-600

A
149.2
181.0
219.1
263.5

B
26.9
39.6
52.3
65.8

600V
A
200.0
244.5
295.3
339.7

B
34.0
46.7
65.8
79.5

Low-Peak

250V
Ampere
70-100
110-200
225-400
450-600

A
149.2
181.0
219.1
263.5

B
29.5
42.2
60.5
73.2

600V
A
200.0
244.5
295.3
339.7

B
29.5
42.2
60.5
73.2

CLASS L

Low-Peak® & Limitron® Fuses
KRP-C, KTU, & KLU (601 - 6000A) (600V)
NOTE: KRP-CL (150A to 600A) fuses
have same dimensions as 601A to
800A case size. KTU (200A to 600A)
have same dimensions, except tube
76.2mm lgth. x 50.8mm dia.; terminal
41,3mm width x 31.8mm thick.

3

®

Bussmann

Electrical - Power Fuses

CUBEFUSE™ and Fuseholder

TCF & TCFH

Finger-Safe Dual-Element Time-Delay Fuses
Indicating – 600 Volts or Less

Catalog Symbol: TCF (Fuse) & TCFH (Holder)
Dual-Element, Time-Delay Fuse: 10 Seconds
Minimum Operating Time at 500% Rated Current
Ampere Rating: 1 to 60A
Voltage Rating: 600Vac (or less)
DC Voltage Rating: 300 Vdc (or less), 100,000AIR
Interrupting Rating: 300,000A RMS Symmetrical (UL)
200,000A RMS Symmetrical (CSA)
Agency Information:
UL Listed Special Purpose Fuse (UL 248-8) (1-60A)
CSA Certified Fuse (CSA-22.2 No. 106) (1-60A)
UL Listed Special Purpose Fuseholder
CSA Certified Fuseholder (C22.2 Nos. 39 & 65)
Other Electrical Certifications:
CE compliance for the European Union Low Voltage
Directive (50-1000Vac, 75-1500Vdc)
Catalog Numbers

1-60 Amps

• The world’s first finger safe industrial fuse system.
• True dual-element fuse construction with a minimum of 10
seconds time-delay at 500% of rating.
• Long time-delay minimizes nuisance circuit openings due
to temporary overloads and transient surges.
• Meets UL Class J Time-Delay electrical performance requirements.
• High interruption rating to safely interrupt faults up to
300,000 amperes.
• Faster response to damaging faults reduces destructive
thermal and magnetic forces.
• Permanent open fuse indication.
• Designed to be an internationally accepted and specified
world class product.
• Smallest footprint of any power class fuse including Class
J, CC, T and RK.
• Meets requirements of IEC 60529 for IP-20 finger safe rating.
• No venting of arc or molten metal and gases during opening.
• Robust cycling and inrush current withstand.
• Low let through currents under fault conditions.
• Provides TYPE 2 “no damage” protection for IEC motors
starters when properly sized.
• Low watt loss reduces power consumption and lowers
operating temperature.
• Conventional Class J fuse case sizes and ampere ratings.
• Dovetail fuseholder design for ganging multiple fuse poles.
• 30 and 60 Amp fuseholders can be ganged together.
• 30 Amp fuses can be plugged into the 60A holder without a
reducer.
• 35mm DIN rail and chassis mounting features.
• Fuseholder wire ports rated for dual wires.
Carton Quantity and Weight

TCF1

TCF3

TCF15

TCF17-1/2

TCF20

TCF25

Ampere
Rating
TCF1-30

TCF30

TCF35

TCF40

TCF45

TCFH1-30

12

2.42

.902

TCF50

TCF60

TCF35-60

12

1.42

.530

TCFH35-60

12

2.57

.958

TCF6

TCF10

Carton.
Qty
12

Weight Per Carton
Lbs.
Kg.
1.39
.518

CUBEFuse™ Fuseholder Catalog Data
Amps
30
60

Poles
1

Wire *
#14 - #8 CU

Dual Wire *
#14 CU

Part Number
TCFH30

1

#14 - #4 CU

#10 CU

TCFH60

Time-Current and Current Limitation Curves on page 219.

* 75ºC (MIN) CU Wire Only

Data Sheet: 9000

4

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

CUBEFUSE™ and Fuseholder
Finger-Safe Dual-Element Time-Delay Fuses
Indicating – 600 Volts or Less
Dimensional Data For TCF and TCFH

Dimension

30A in [mm]

TCF & TCFH
1-60 Amps

Time-Current Characteristic Curves–Average Melt

60A in [mm]

A

1.88 [47.75]

B

.75 [19.05]

2.13 [54.10]
1.00 [25.40]

C

1.00 [25.40]

1.13 [28.58]

D

.31 [7.94]

.44 [11.11]

E

.04 [1.02]

.04 [1.02]

F

.63 [15.88]

.63 [15.88]

G

.27 [6.86]

.38 [9.65]

H

2.30 [58.42]

2.60 [66.04]

I

.76 [19.30]

1.03 [26.16]

J

1.27 [32.18]

1.53 [38.86]

K

.15 [3.81]

.17 [4.32]

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

5

®

Electrical - Power Fuses

Bussmann

Low-Peak® Time-Delay, Class L Fuses

O-RING SEALS
Formation of arc gas within fuse
body suppresses arcing; lowers
arcing I2t energy. O-ring seals
maximize pressure build-up during
current limiting action. Also volume
of sand is critical. Slight loss can
adversely impact on current limiting action. O-ring seals insure filler
retention. They compensate to a
degree for switchgear misalignment, and expansion and contraction of mounting surfaces
with change in load to no-load
conditions.

KRP-C_SP
Time-Delay – 4 seconds (minimum) at 500% rated current
Ampere Ratings: 601-6000A†
Voltage Rating: 600Vac (or less), 300Vdc for 601-2000A.
Interrupting Rating: ac: 300,000A RMS Sym.
dc: 100,000A
Agency Information:
UL Listed-Special Purpose (meets all performance
requirements of UL Standard 248-10 for Class L fuses),
Guide JFHR, File E56412
CSA Certified (200,000 AIR), Class 1422-02, File 53787,
Class L per CSA C22.2, No. 248.10
Dimensions: See pages 2-3 for Class L dimensional data.

Ordering Information
Catalog
Number

Ctn.
Qty.

Weight**
Lbs.

Kg.

KRP-C-601SP

KRP-C-1900SP
1

3.75

1.7

KRP-C-2001SP

KRP-C-800SP

KRP-C-2400SP

KRP-C-801SP

KRP-C-2500SP

KRP-C-900SP

KRP-C-3000SP
1

4.5

2.041

KRP-C-3800SP

KRP-C-1200SP

KRP-C-4000SP

KRP-C-1350SP

KRP-C-4500SP

KRP-C-1500SP

Kg.

1

8.5

3.85

1

17.25

7.824

1

18.25

8.278

1

23.50

10.659

1

29

13.154

1

36

16.329

KRP-C-3500SP

KRP-C-1100SP

KRP-C-1400SP

Lbs.

KRP-C-2000SP

KRP-C-750SP

KRP-C-1000SP

Weight**

Ctn.
Qty.

KRP-C-1800SP

KRP-C-650SP
KRP-C-700SP

Catalog
Number

1

6.50

2.948

KRP-C-5000SP
KRP-C-6000SP

SAND FILLER
High grade silica-sand filler.
Accelerates response of fuse to
short-circuits by having quenching
effect upon the fuse arc.
Substantially contributes to current
limiting action.

99.9% PURE SILVER
FUSELINKS
Embody “silver-sand” design.
99.9% pure silver links; silicasand filler. The high conductivity of
silver gives low watt loss and low
operating temperature at normal
current levels; minimizes total
clearing I2t fault energy let-thru…
state-of-art fuse design. High
degree of current limitation holds
down fault currents and levels of
destructive energy. (Although other
link materials can provide current
limitation, they do not equal that
of silver.)

• All-purpose silver linked fuse for both overload and shortcircuit protection for high capacity systems (mains and large
feeders).
• Time-delay (minimum of four seconds at five times amp rating)
for close sizing.
• Current limiting action of the fuse generally affords considerable reduction in bus bracing.
• Interrupting rating of 300,000 amperes complies with
NEC Sections 110-9 and 230-65 for today’s large capacity
systems.
• O-ring seals maximize pressure build-up during current limiting
action and ensure filler retention.
• High grade silica-sand filler; accelerates response of fuse to
short-circuits by having quenching effect upon the fuse arc.
• 99.9% pure silver fuselinks. The high conductivity of silver
gives low watt loss and low operating temperature at normal
current levels; minimizes total clearing I 2t fault energy let-thru.
• Selective coordination (blackout prevention)
• Glass melamine tube.
• Silver plated end bells.
• Reducers not necessary.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

KRP-C-1600SP
Special purpose rating of 300,000 AIR.
**Weight per carton.
†Use KRP-CL for current ratings below 601A.

Data Sheet: 1008 and 1009

6

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

4000A
5000A
6000A

1600A
2000A
2500A
3000A

1200A

800A

Time-Current Characteristic Curves—Average Melt
KRP-C

Current Limitation Curves—KRP-C
1000,000

B

AMPERE
RATING

AMPERE
RATING
A

1,000

300,000

1

10,000

100,000

TIME IN SECONDS

10

100,000

10,000

100

6,000A
5,000A
4,000A
3,000A
2,500A
2,000A
1,600A
1,200A
800A
601A

1,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

300

PROSPECTIVE SHORT CIRCUIT CURRENT
SYMMETRICAL RMS AMPERES

Recommended Fuseblocks for Class L: (601–1200A)
.1

Catalog Number

Poles

51215

1

51235

3

200,000

100,000

1,000

.01
CURRENT IN
AMPERES

10,000

Use KRP-CL for current ratings below 601A.

KRP-CL

Dimensions: See pages 2-3 for Class L dimensional data.

Current Limiting, Time-Delay
Construction: Glass Melamine Tube
Ampere Ratings: 150-600A.
Voltage Rating: 600Vac (or less)
These fuses have the same performance characteristics as
KRP-C fuses. They are used in applications where there is a
need for Class L dimension fuses with 150-600A ratings.
KRP-CL fuses have the same dimensions as
800A Class L fuses.

Ordering Information
Catalog Number (Symbol & Amps)
KRP-CL-150

KRP-CL-300

KRP-CL-500

KRP-CL-200

KRP-CL-350

KRP-CL-600

KRP-CL-225

KRP-CL-400

KRP-CL-250

KRP-CL-450

Weight of each is 3.75 lbs.

Data Sheet: 1016
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

7

®

Electrical - Power Fuses

Bussmann

Limitron® Class L Fuses

KTU

KLU

Fast Acting, Bolt Mount
Ampere Ratings: 601-6000A.
Voltage Rating: 600Vac (or less)
Interrupting Rating: 200,000 RMS Sym.
Agency Information: Std. 248-10, Class L
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class L dimensional data.

Time-Delay – 5 seconds (minimum) at 500%
rated current
Bolt Mount
Ampere Ratings: 601-4000A.
Voltage Rating: 600Vac (or less)
Interrupting Rating: 200,000A RMS Sym.
Agency Information: Std. 248-10, Class L
UL Listed, Guide JDDZ, File E4273
CSA Certified, CSA Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class L dimensional data.

Ordering Information
Catalog
Number

Ctn.
Qty.

Weight**
Lbs.

Kg.

Catalog
Number

KTU-601

KTU-1800

KTU-650

KTU-2000

KTU-700

1

3.75

1.70

KTU-2400

KTU-750

KTU-2500

KTU-800

KTU-3000

KTU-801

KTU-3001

KTU-900

KTU-4000

KTU-1100

1

4.25

1.927

KTU-4500

KTU-1200

KTU-5000

KTU-1350

KTU-6000

KTU-1400
KTU-1500

1

6

Weight**

Ctn.
Qty.

Lbs.

Kg.

1

8.5

3.855

1

17

7.711

1

17.25

7.824

1

24

10.886

1

31

14.061

1

34

15.422

Recommended Fuseblocks for Class L: (601–1200A)
1
3

Kg.

KLU-700
KLU-1000
KLU-1500
KLU-1600

Catalog
Number

Weight**

Ctn.
Qty.

Lbs.

Kg.

1

8.50

3.86

KLU-1800
KLU-2000
1

3.75

1.70

KLU-2500
KLU-3000

1

4.25

1.93

1

6.00

2.72

KLU-4000

**Weight per carton.

• For protection of circuit breakers with lower interrupting
ratings and non-inductive loads such as lighting and
heating circuits.
• 99.9% pure silver-links.
• Reducers not necessary.

51235

Weight**
Lbs.

KLU-650

KLU-1200

**Weight per carton.

51215

Ctn.
Qty.

KLU-800

KTU-1600

Poles

Catalog
Number
KLU-601

2.721

Catalog Number

Ordering Information

• KLU Limitron® general purpose copper link fuses.
• Current limiting—provides component short-circuit
protection.
• Fuse reducers not necessary.
• See KRP-CL for current ratings below 601A
Recommended Fuseblocks: (601–1200A)
Catalog Number

Poles

51215

1

51235

3

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1010

8

Data Sheet: 1013
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Low-Peak® Dual-Element, Time-Delay, Class RK1 Fuses

LPN-RK_SP (250V)
LPS-RK_SP (600V)
Dual-Element, Time-Delay – 10 seconds (minimum) at
500% rated current (8 seconds for 0-30A sizes)
Ampere Ratings: ⁄Ω¡º-600A.
Voltage Rating: LPN-RK: 250Vac (or less),
125Vdc (⁄Ω¡º-60A); 250Vdc (70-600 A)
LPS-RK: 600Vac (or less), 300Vdc
Current Limiting RK1 Fuse
Interrupting Rating:
ac: 300,000A RMS Sym.
dc: 100,000A
Agency Information:
UL Listed – Special Purpose**, Guide JFHR, File E56412
CSA Certified (200,000 AIR), Class RK1 per CSA C22.2,
No. 248.12, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class RK1 dimensional data.
Catalog Numbers (250Vac/125Vdc)

• Current limitation for maximum short-circuit protection.
High speed of response is highly sensitive to fault currents, but
insensitive to starting current and transient surges.
• Provides long time-delay for temporary motor start-up.
• Time-delay permits 125% FLA sizing for back-up, motor running
protection.
Catalog Numbers (600Vac/300Vdc)
LPS-RK-⁄Ω¡ºSP

LPS-RK-2⁄Ω™SP

LPS-RK-12SP

LPS-RK-¤Ω¡ºSP

LPS-RK-2°Ω¡ºSP

LPS-RK-15SP

LPS-RK-125SP

LPS-RK-‹Ω¡ºSP

LPS-RK-3SP

LPS-RK-17⁄Ω™SP

LPS-RK-150SP

LPS-RK-›Ω¡ºSP

LPS-RK-3¤Ω¡ºSP

LPS-RK-20SP

LPS-RK-175SP

LPS-RK-⁄Ω™SP

LPS-RK-3⁄Ω™SP

LPS-RK-25SP

LPS-RK-200SP

LPS-RK-flꭧSP

LPS-RK-4SP

LPS-RK-30SP

LPS-RK-225SP

LPS-RK-°Ω¡ºSP

LPS-RK-4⁄Ω™SP

LPS-RK-35SP

LPS-RK-250SP

LPS-RK-1SP

LPS-RK-5SP

LPS-RK-40SP

LPS-RK-300SP

LPS-RK-1⁄Ω•SP

LPS-RK-5flꭧSP

LPS-RK-45SP

LPS-RK-350SP

LPS-RK-1⁄Ω¢SP

LPS-RK-6SP

LPS-RK-50SP

LPS-RK-400SP

LPS-RK-1›Ω¡ºSP

LPS-RK-6⁄Ω¢SP

LPS-RK-60SP

LPS-RK-450SP

LPS-RK-1⁄Ω™SP

LPS-RK-7SP

LPS-RK-70SP

LPS-RK-500SP

LPS-RK-1flꭧSP

LPS-RK-8SP

LPS-RK-80SP

LPS-RK-600SP

LPS-RK-1°Ω¡ºSP

LPS-RK-9SP

LPS-RK-90SP

LPS-RK-2⁄Ω¢SP

LPS-RK-10SP

LPS-RK-100SP

LPN-RK-⁄Ω¡ºSP

LPN-RK-3⁄Ω™SP

LPN-RK-60SP

LPN-RK-⁄fiΩ¡ººSP

LPN-RK-4SP

LPN-RK-70SP

LPN-RK-¤Ω¡ºSP

LPN-RK-4⁄Ω™SP

LPN-RK-80SP

LPN-RK-‹Ω¡ºSP

LPN-RK-5SP

LPN-RK-90SP

LPN-RK-›Ω¡ºSP

LPN-RK-5flꭧSP

LPN-RK-100SP

LPN-RK-⁄Ω™SP

LPN-RK-6SP

LPN-RK-110SP

Carton Quantity and Weight

LPN-RK-flꭧSP

LPN-RK-6⁄Ω¢SP

LPN-RK-125SP

LPN-RK (250Vac)

LPS-RK-110SP

**Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.

LPN-RK-°Ω¡ºSP

LPN-RK-8SP

LPN-RK-150SP

LPN-RK-1SP

LPN-RK-9SP

LPN-RK-175SP

LPN-RK-1⁄Ω•SP

LPN-RK-10SP

LPN-RK-200SP

0-30

10

LPN-RK-1⁄Ω¢SP

LPN-RK-12SP

LPN-RK-225SP

35-60

Ampere
Ratings

Carton
Qty.

LPS-RK (600Vac)
Weight*

Weight*

Kg

Carton
Qty.

Lbs.

Kg

0.5

0.227

10

1.6

0.725

10

1.2

0.544

10

2.6

1.178

5

1.5

0.680

5

4.0

1.814

Lbs.

LPN-RK-1›Ω¡ºSP

LPN-RK-15SP

LPN-RK-250SP

70-100

LPN-RK-1flꭧSP

LPN-RK-17⁄Ω™SP

LPN-RK-300SP

110-200

1

0.69

0.313

1

2.0

0.906

LPN-RK-1°Ω¡ºSP

LPN-RK-20SP

LPN-RK-350SP

225-400

1

1.75

0.793

1

4.6

2.086

LPN-RK-400SP

450-600

1

3.25

1.474

1

5.6

2.540

LPN-RK-2SP

LPN-RK-25SP

LPN-RK-2⁄Ω¢SP

LPN-RK-30SP

LPN-RK-450SP

LPN-RK-2⁄Ω™SP

LPN-RK-35SP

LPN-RK-500SP

LPN-RK-2°Ω¡ºSP

LPN-RK-40SP

LPN-RK-600SP

LPN-RK-3SP

LPN-RK-45SP

LPN-RK-3¤Ω¡ºSP

LPN-RK-50SP

*Weight per carton.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

**Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
0-60A fuses available with Nickel plate option. (Ex: LPSRK30SPNP)
70-600A fuses available with Tin plate option. (Ex: LPS-RK-100SP-TP)

Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600)

Data Sheet: (LPS-RK) 1001 (0-60) & 1002 (70-600)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

9

®

Electrical - Power Fuses

Bussmann

Low-Peak® Dual-Element, Time-Delay, Class RK1 Fuses
Time-Current Characteristic Curves—Average Melt
60

100

200

400 600

AMPERE
RATING

10

10

60

100

200

400 600

AMPERE
RATING

.01

.01

61/4
10

2

32/10

/

11/4

2 10

/
/

/
1
16/10
21/2
4
5
8
12

AMPERE
RATING

8 10

/
/

/

/

1 10
15 100

4
5
8
10
12

AMPERE RATING

1 2
6 10

CURRENT IN AMPERES

6 1 /4

2 1 /2
32/10

8/10

1 1 /4

2

16/10

1

6/10

3/10
4/10

2/10

1 /2

15/100

20

100

20

10,000

.1

1,000

.1

10,000

1

1,000

1

100

TIME IN SECONDS

100

TIME IN SECONDS

100

1/10

30

300

CURRENT IN AMPERES

300

20

3 10
4 10

300

15 20 30

LPN-RK
250V

LPS-RK
600V

100

TIME IN SECONDS

TIME IN SECONDS

10

1

CURRENT IN AMPERES

RMS SYMMETRICAL CURRENT IN AMPERES

Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600)

10

1,000

100

10

.1

.01

1

.1

CURRENT IN AMPERES

Data Sheet: (LPS-RK) 1001 (0-60) & 1002 (70-600)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Low-Peak® Dual-Element, Time-Delay, Class RK1 Fuses
Current Limitation Curves—LPN-RK (250V)
B

AMPERE
RATING

400,000

100,000

600
400
200
100
60

10,000

30

200,000

100,000

1,000

10,000

A

1,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

Recommended fuseblocks for
Class R 250 & 600V fuses
See pages 47-52

RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

B

AMPERE
RATING

400,000

100,000

600
400
200
100
60

10,000

30

200,000

10,000

1,000

100,000

A

1,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

Current Limitation Curves—LPS-RK (600V)

RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

Data Sheet: (LPN-RK) 1003 (0-60) & 1004 (70-600)

Data Sheet: (LPS-RK) 1001 (0-60) & 1002 (70-600)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

11

®

Electrical - Power Fuses

Bussmann

Fusetron® Dual-Element, Time-Delay, Class RK5 Fuses
• Provides motor overload, ground fault and short-circuit
protection when sized properly.
• Helps protect motors against burnout from overloads when
sized properly.
• Helps protect motors against burnout from single phasing
on three phase systems when sized properly.
• Simplifies and improves blackout prevention (selective
coordination) when sized properly.
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips

FRN-R (250V)

Desired
Fuse (Case)
Size

60A

Dual-Element, Time-Delay – 10 seconds (minimum) at
500% rated current
Ampere Ratings: ⁄Ω¡º-600A.
Voltage Rating: 250Vac (or less), 125Vdc
Current Limiting RK5 Fuse
Interrupting Rating: 200,000A RMS Sym.
(20,000A @ 125Vdc)
Agency Information: Std. 248-12, Class RK5
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-01, File 53787
Dimensions: See pages 2-3 for Class RK5 dimensional data.
Catalog Numbers (250Vac/125Vdc)
FRN-R-⁄Ω¡º

FRN-R-2

FRN-R-10

FRN-R-100

FRN-R-⁄Ω•

FRN-R-2⁄Ω¢

FRN-R-12

FRN-R-110

FRN-R-⁄fiΩ¡ºº

FRN-R-2⁄Ω™

FRN-R-15

FRN-R-125

FRN-R-¤Ω¡º

FRN-R-2°Ω¡º

FRN-R-17⁄Ω™

FRN-R-150

FRN-R-⁄Ω¢

FRN-R-3

FRN-R-20

FRN-R-175

FRN-R-‹Ω¡º

FRN-R-3¤Ω¡º

FRN-R-25

FRN-R-200

FRN-R-›Ω¡º

FRN-R-3⁄Ω™

FRN-R-30

FRN-R-225

FRN-R-⁄Ω™

FRN-R-4

FRN-R-35

FRN-R-250

FRN-R-flꭧ

FRN-R-4⁄Ω™

FRN-R-40

FRN-R-300

FRN-R-°Ω¡º

FRN-R-5

FRN-R-45

FRN-R-350

FRN-R-1

FRN-R-5flꭧ

FRN-R-50

FRN-R-400

FRN-R-1⁄Ω•

FRN-R-6

FRN-R-60

FRN-R-450

FRN-R-1⁄Ω¢

FRN-R-6⁄Ω¢

FRN-R-70

FRN-R-500

FRN-R-1›Ω¡º

FRN-R-7

FRN-R-75

FRN-R-600

FRN-R-1⁄Ω™

FRN-R-7⁄Ω™

FRN-R-80

FRN-R-1flꭧ

FRN-R-8

FRN-R-85

FRN-R-1°Ω¡º

FRN-R-9

FRN-R-90

100A
200A

400A

600A

Catalog Number
(Pairs)
250V

30A

No. 263-R

30A

No. 213-R

60A

No. 216-R

60A

No. 226-R

100A

No. 2621-R

100A

No. 2641-R

200A

No. 242-R

100A

No. 2661-R

200A

No. 2662-R

400A

No. 2664-R*

*Single reducer only (pair not required).

Time-Current and Current Limitation Curves located on
page 223.
Recommended fuseblocks for
Class R 250V fuses
See pages 47-49

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Carton Quantity and Weight
Ampere
Ratings

Weight*

Carton
Qty.

Lbs.

Kg.

0-15

10

0.40

0.181

17.5-30

10

.50

0.227

35-60

10

1.00

0.453

70-100

5

1.5

0.680

101-200

1

0.77

0.349

201-400

1

1.52

0.689

401-600

1

2.94

1.334

*Weight per carton.

Data Sheet: 1019 (0-60), 1020 (70-600)

12

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Fusetron® Dual-Element, Time-Delay, Class RK5 Fuses

FRS-R (600V)

Fuse Reducers For Class R Fuses

Dual-Element, Time-Delay – 10 seconds (minimum) at
500% rated current
Ampere Ratings: ⁄Ω¡º-600A.
Voltage Rating: 600Vac (or less), 300Vdc
Current Limiting RK5 Fuse
Interrupting Rating: 200,000A RMS Sym.
(20,000A @ 300Vdc)
Agency Information: Std. 248-12, Class RK5
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class RK5 dimensional data.
Catalog Numbers (600Vac/ 300Vdc)

Equipment
Fuse Clips

Desired
Fuse (Case)
Size

60A
100A
200A
400A

600A

Catalog Number
(Pairs)
600V

30A

No. 663-R

30A

No. 216-R

60A

No. 616-R

60A

No. 626-R

100A

No. 2621-R

100A

No. 2641-R

200A

No. 642-R

100A

No. 2661-R

200A

No. 2662-R

400A

No. 2664-R*

*Single reducer only (pair not required).

FRS-R-⁄Ω¡º

FRS-R-2

FRS-R-10

FRS-R-110

FRS-R-⁄Ω•

FRS-R-2⁄Ω¢

FRS-R-12

FRS-R-125

FRS-R-⁄fiΩ¡ºº

FRS-R-2⁄Ω™

FRS-R-15

FRS-R-150

FRS-R-¤Ω¡º

FRS-R-2°Ω¡º

FRS-R-17⁄Ω™

FRS-R-175

FRS-R-⁄Ω¢

FRS-R-3

FRS-R-20

FRS-R-200

FRS-R-‹Ω¡º

FRS-R-3¤Ω¡º

FRS-R-25

FRS-R-225

FRS-R-›Ω¡º

FRS-R-3⁄Ω™

FRS-R-30

FRS-R-250

FRS-R-⁄Ω™

FRS-R-4

FRS-R-35

FRS-R-275

FRS-R-flꭧ

FRS-R-4⁄Ω™

FRS-R-40

FRS-R-300

FRS-R-°Ω¡º

FRS-R-5

FRS-R-45

FRS-R-325

FRS-R-1

FRS-R-5flꭧ

FRS-R-50

FRS-R-350

FRS-R-1⁄Ω•

FRS-R-6

FRS-R-60

FRS-R-400

FRS-R-1⁄Ω¢

FRS-R-6⁄Ω¢

FRS-R-70

FRS-R-450

FRS-R-1›Ω¡º

FRS-R-7

FRS-R-75

FRS-R-500

FRS-R-1⁄Ω™

FRS-R-7⁄Ω™

FRS-R-80

FRS-R-600

FRS-R-1flꭧ

FRS-R-8

FRS-R-90

FRS-R-1°Ω¡º

FRS-R-9

FRS-R-100

Time-Current and Current Limitation Curves located on
page 224.

Recommended fuseblocks for
Class R 600V fuses
See pages 50-52

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet #8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Carton Quantity and Weight
Ampere
Ratings
0-15

Weight*

Carton
Qty.

Lbs.

Kg.

10

0.40

0.181
0.227

17.5-30

10

0.50

35-60

10

3.10

1.406

65-100

1

0.54

0.245

101-200

1

1.22

0.544

201-400

1

3.00

1.359

401-600

1

5.00

2.268

*Weight per carton.

Data Sheet: 1017 (0-60), 1018 (70-600)
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

13

®

Electrical - Power Fuses

Bussmann

Dura-Lag™ Dual-Element, Time-Delay, Class RK5 Fuses

DLN-R (250V)

DLS-R (600V)

Dual-Element, Time-Delay – 10 seconds (minimum) at
500% rated current
Ampere Ratings: 1-600A
Voltage Rating: 250Vac (or less), 125Vdc
Current Limiting RK5 Fuses
Interrupting Rating: 200,000A RMS Sym.
(20,000A @125Vdc)
Agency Information: Std. 248-12, Class RK5
UL Listed, Guide JDDZ, File E4273
CSA C22.2, No. 106-HRCI-R, File 53787
Dimensions: See pages 2-3 for Class RK5 dimensional data.

Dual-Element, Time-Delay – 10 seconds (minimum) at
500% rated current
Ampere Ratings: 1-600A
Voltage Rating: 600Vac (or less), 300Vdc
Current Limiting RK5 Fuses
Interrupting Rating: 200,000A RMS Sym.,
(20,000A @ 300Vdc)
Agency Information: Std. 248-12, Class RK5
UL Listed, Guide JDDZ, File E4273
CSA C22.2, No. 106-HRCI-R
Dimensions: See pages 2-3 for Class RK5 dimensional data.

Catalog Numbers (250Vac/125Vdc)

Catalog Numbers (600Vac/300Vdc)

DLN-R-1
DLN-R-2
DLN-R-2⁄Ω™
DLN-R-3
DLN-R-3¤Ω¡º
DLN-R-4
DLN-R-5
DLN-R-6
DLN-R-6⁄Ω¢
DLN-R-8
DLN-R-10
DLN-R-12

DLN-R-15
DLN-R-20
DLN-R-25
DLN-R-30
DLN-R-35
DLN-R-40
DLN-R-45
DLN-R-50
DLN-R-60
DLN-R-70
DLN-R-80
DLN-R-90

DLN-R-100
DLN-R-125
DLN-R-150
DLN-R-175
DLN-R-200
DLN-R-225
DLN-R-250
DLN-R-300
DLN-R-400
DLN-R-600

Carton Quantity and Weight
Ampere
Ratings
⁄Ω¡º-30
35-60

Weight*

Carton
Qty.

Lbs.

Kg.

10

0.56

0.252

10

1.38

0.621

70-100

5

1.56

0.702

110-200

1

0.90

0.405

225-400
450-600

1
1

1.80
3.30

0.810
1.485

*Weight per carton.

Recommended fuseblocks for
Class R 250V fuses
See pages 47-49

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1021 (0-600)

14

DLS-R-1
DLS-R-1flꭧ
DLS-R-2
DLS-R-2⁄Ω™
DLS-R-3
DLS-R-3⁄Ω™
DLS-R-4
DLS-R-5
DLS-R-6
DLS-R-6⁄Ω¢
DLS-R-7
DLS-R-8
DLS-R-9
DLS-R-10

DLS-R-12
DLS-R-15
DLS-R-17⁄Ω™
DLS-R-20
DLS-R-25
DLS-R-30
DLS-R-35
DLS-R-40
DLS-R-45
DLS-R-50
DLS-R-60
DLS-R-70
DLS-R-80
DLS-R-90

DLS-R-100
DLS-R-110
DLS-R-125
DLS-R-150
DLS-R-175
DLS-R-200
DLS-R-225
DLS-R-250
DLS-R-300
DLS-R-350
DLS-R-400
DLS-R-500
DLS-R-600

Carton Quantity and Weight
Ampere
Ratings

Weight*

Carton
Qty.

Lbs.

Kg.

⁄Ω¡º-30

10

1.62

0.729

35-60

10

3.00

1.35

70-100

5

3.00

1.35

110-200

1

1.41

0.635

225-400

1

3.13

1.409

450-600

1

5.28

2.376

*Weight per carton.

Recommended fuseblocks for
Class R 600V fuses
See pages 50-52
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1022 (0-600)
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Limitron® Fast Acting, Class RK1 Fuses

KTN-R (250V)

KTS-R (600V)

Fast Acting
Ampere Ratings: 1-600A
Voltage Rating: 250Vac (or less).
Current Limiting RK1 Fuse (curves on page 205)
Interrupting Rating: 200,000A RMS Sym.
Agency Information: Std. 248-12, Class RK1
UL Listed, Guide JDDZ, File E54273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class RK1 dimensional data.

Fast Acting
Ampere Ratings: 1-600A
Voltage Rating: 600Vac (or less).
Current Limiting RK1 Fuse (curves on page 206)
Interrupting Rating: 200,000A RMS Sym.
Agency Information: Std. 248-12, Class RK1
UL Listed, Guide JDDZ, File E54273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class RK1 dimensional data.

Catalog Numbers (250Vac)

Catalog Numbers (600Vac)

KTN-R-1
KTN-R-2
KTN-R-3
KTN-R-4
KTN-R-5
KTN-R-6
KTN-R-8
KTN-R-10
KTN-R-12
KTN-R-15
KTN-R-20
KTN-R-25

KTN-R-30
KTN-R-35
KTN-R-40
KTN-R-45
KTN-R-50
KTN-R-60
KTN-R-70
KTN-R-75
KTN-R-80
KTN-R-90
KTN-R-100
KTN-R-110

KTN-R-125
KTN-R-150
KTN-R-175
KTN-R-200
KTN-R-225
KTN-R-250
KTN-R-300
KTN-R-350
KTN-R-400
KTN-R-450
KTN-R-500
KTN-R-600

Carton Quantity and Weight

KTS-R-1
KTS-R-2
KTS-R-3
KTS-R-4
KTS-R-5
KTS-R-6
KTS-R-8
KTS-R-10
KTS-R-12
KTS-R-15
KTS-R-20
KTS-R-25

KTS-R-30
KTS-R-35
KTS-R-40
KTS-R-45
KTS-R-50
KTS-R-60
KTS-R-70
KTS-R-75
KTS-R-80
KTS-R-90
KTS-R-100
KTS-R-110

KTS-R-125
KTS-R-150
KTS-R-175
KTS-R-200
KTS-R-225
KTS-R-250
KTS-R-300
KTS-R-350
KTS-R-400
KTS-R-450
KTS-R-500
KTS-R-600

Carton Quantity and Weight
Weight*

Weight*

Ampere
Ratings

Carton
Qty.

Lbs.

Kg.

Ampere
Ratings

Carton
Qty.

Lbs.

Kg.

1-30
40-60
70-100
110-200
225-400
450-600

10
10
5
1
1
1

.45
1.82
1.85
1.05
2.38
3.50

0.204
0.824
0.838
0.476
1.078
1.587

1-30
40-60
70-100
110-200
225-400
450-600

10
10
1
1
1
1

1.45
2.63
0.5
1.4
2.75
4.25

0.657
1.262
0.226
0.634
1.246
1.925

*Weight per carton.

*Weight per carton.

Time-Current and Current Limitation Curves located on
page 225.

Time-Current and Current Limitation Curves located on
page 226.

Recommended fuseblocks for
Class R 250V fuses
See pages 47-49

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Recommended fuseblocks for
Class R 600V fuses
See pages 50-52

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1043 (0-600)
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 1044 (0-600)

15

®

Electrical - Power Fuses

Bussmann

One-Time General Purpose Fuses
NON and NOS
General Purpose Application
Non-Current Limiting
Ampere Ratings: ⁄Ω•-600A
Voltage Rating: NON: 250Vac, 125Vdc (0-100A);
NOS: 600Vac
Interrupting Rating: 50,000A RMS Sym. (0-60A),
10,000A RMS Sym. (65-600A), 50,000A @ 125Vdc
(NON 0-60),
10,000A @ 125Vdc (NON 65-100A)
Agency Information:
UL Listed – 250V: Class K5 (0-60A), Std. 248-9
Class H (65-600A), Std. 248-6
(125Vdc: NON 0-100)
600V: Class K5 (0-60A), Std. 248-9
Class H (70-600A), Std. 248-6
Guide JDDZ, File E4273
CSA Certified – 250V: (0-12, 65-600)†
600V: (0-600)
Class 1421-01, File 53787
Dimensions: See pages 2-3 for dimensional data under
Class RK5/RK1.
† For CSA Certified 15-60A Ratings, see PON Data Sheet 4126
Catalog Numbers (250Vac)
NON-⁄Ω•
NON-⁄Ω™
NON-‹Ω¢
NON-°Ω¡º
NON-1
NON-1⁄Ω¢
NON-1⁄Ω™
NON-1flꭧ
NON-2
NON-2⁄Ω™
NON-3
NON-3¤Ω¡º
NON-4

NON-5
NON-6
NON-6⁄Ω¢
NON-7
NON-8
NON-9
NON-10
NON-12
NON-15
NON-20
NON-25
NON-30
NON-35

NON-40
NON-45
NON-50
NON-60
NON-65
NON-70
NON-75
NON-80
NON-90
NON-100
NON-110
NON-125
NON-150

NON-175
NON-200
NON-225
NON-250
NON-300
NON-350
NON-400
NON-450
NON-500
NON-600
—
—
—

Recommended Fuse Reducers
250V

600V

Cat.
Clip
Fuse
No.
Size
Size
(Pair)
60A
30A
No. 263
100A
30A
No. 213
100A
60A
No. 216
200A
60A
No. 226
200A
100A
No. 2621
400A
100
No. 2641
400A
200A
No. 2642
600A
100A
No. 2661
600A
200A
No. 2662
600A
400A
No. 2664
*Carton quantity—10 pair.

Weight
Carton*
(lbs)
0.38
1.73
1.73
3.00
1.63
4.90
3.50
8.70
6.85
4.45

Clip
Size
60A
100A
100A
200A
200A
400A
400A
600A
600A
600A

Fuse
Size
30A
30A
60A
60A
100A
100
200A
100A
200A
400A

Cat.
No.
(Pair)
No. 663
No. 216
No. 616
No. 626
No. 2621
No. 2641
No. 2642
No. 2661
No. 2662
No. 2664

Weight
Carton*
(lbs)
1.00
1.73
1.85
3.33
1.63
4.90
3.50
8.70
6.85
4.45

Catalog Numbers (600Vac)
NOS-1
NOS-2
NOS-3
NOS-4
NOS-5
NOS-6
NOS-7
NOS-8
NOS-9
NOS-10

NOS-12
NOS-15
NOS-20
NOS-25
NOS-30
NOS-35
NOS-40
NOS-45
NOS-50
NOS-60

NOS-70
NOS-75
NOS-80
NOS-90
NOS-100
NOS-110
NOS-125
NOS-150
NOS-175
—

NOS-200
NOS-225
NOS-250
NOS-300
NOS-350
NOS-400
NOS-450
NOS-500
NOS-600
—

Carton Quantity and Weight
Carton Quantity and Weight
Ampere
Ratings
NON
NON
NON
NON
NON
NON

Ampere
Ratings

Weight*

Carton
Qty.

Lbs.

Kg.

10
10
5
1
1
1

0.38
1.00
0.79
0.79
1.65
2.76

0.172
0.453
0.358
0.358
0.748
1.25

⁄Ω•-30
35-60
65-100
110-200
225-400
450-600

NOS
NOS
NOS
NOS
NOS
NOS

1-30
35-60
70-100
110-200
225-400
450-600

Weight*

Carton
Qty.

Lbs.

Kg.

10
10
5
1
1
1

1.45
2.6
2.80
1.24
3.03
4.63

0.657
1.179
1.270
0.562
1.374
2.100

*Weight per carton.

*Weight per carton.

Catalog Symbol & Current Ratings
Symbol
NON

NOS

Rating
0-60
65-600
0-60
65-100
0-60
70-600

Class
K5
H
K5
H
K5
H

Volt
250ac
250ac
125dc
125dc
600
600

IR
50,000
10,000
50,000
10,000
50,000
10,000

Recommended fuseblocks for
Class H (K) 250 & 600V fuses
See pages 47-52
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1030

16

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Low-Peak® Dual-Element, Time-Delay, Class J Fuses
LPJ_SP

600A

400A

125A
200A
250A

60A
80A
100A

30A

15A

10A

6A

3A

AMPERE
RATING

TIME IN SECONDS

1A

Time-Current Classification Curves—Average Melt
Dual-Element,
Time-Delay –
300
10 seconds (minimum) at
200
500% rated current
100
Ampere Ratings:
1-600A
Voltage Rating:
600Vac (or less),
300Vdc (or less)
10
Current Limiting
Interrupting Rating:
ac – 300,000A RMS Sym. dc – 100,000A
Agency Information:
UL Listed - Special Purpose**, Guide JFHR, File E56412
1
CSA Certified (200,000 AIR) Class J per CSA-22.2 No. 248.8,
Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class J dimensional data.
Catalog Numbers

LPJ-200SP

LPJ-2SP

LPJ-7SP

LPJ-45SP

LPJ-225SP

LPJ-2⁄Ω¢SP

LPJ-8SP

LPJ-50SP

LPJ-250SP

LPJ-2⁄Ω™SP

LPJ-9SP

LPJ-60SP

LPJ-300SP

LPJ-2°Ω¡ºSP

LPJ-10SP

LPJ-70SP

LPJ-350SP

LPJ-3SP

LPJ-12SP

LPJ-80SP

LPJ-400SP

.01

CURRENT IN AMPERES

Current Limitation Curves

LPJ-15SP

LPJ-90SP

LPJ-450SP

LPJ-3⁄Ω™SP

LPJ-17⁄Ω™SP

LPJ-100SP

LPJ-500SP

LPJ Current Limitation Curves

LPJ-4SP

LPJ-20SP

LPJ-110SP

LPJ-600SP

100,000

Lbs.

Kg.

10

1.09

0.49

35-60

10

1.78

0.81

70-100

5

1.69

0.77

110-200

5

4.21

1.91

225-400

1

1.67

0.76

450-600

1

2.80

0.27

*Weight per carton.

Recommended fuseblocks/fuseholders for
Class J 600V fuses
• Open fuseblocks - see pages 53-55
• Finger-safe fuseholders for 30A & 60Asee pages 57-58
• Modular fuseblocks - see page 67

200A
100A
60A

10,000

30A
15A
AMPERE
RATING

0-30

Weight*

Carton
Qty.

1,000

A
100

1,000

Ampere
Ratings

B
600A
400A

100

Carton Quantity and Weight

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

LPJ-3¤Ω¡ºSP

**Meets all performance requirements of UL Standard 248-8 for Class J fuses.
Available with silver plated terminals. Add SP/ in front of part number.

10,000

LPJ-175SP

LPJ-40SP

200,000

LPJ-35SP

LPJ-6SP

300,000

LPJ-5flꭧSP

LPJ-1°Ω¡ºSP

100,000

LPJ-1flꭧSP

.1

1,000

LPJ-150SP

10,000

LPJ-125SP

LPJ-30SP

100

LPJ-25SP

LPJ-5SP

10

LPJ-4⁄Ω™SP

LPJ-1⁄Ω¢SP

1

LPJ-1SP

PROSPECTIVE SHORT-CIRCUIT CURRENT
SYMMETRICAL RMS AMPS

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1006 (0-60) and 1007 (70-600)
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

17

®

Electrical - Power Fuses

Bussmann

Limitron® Quick Acting, Class J Fuses

JKS

Recommended fuseblocks/fuseholders for
Class J 600V fuses
• Open fuseblocks - see pages 53-55
• Finger-safe fuseholders for 30A & 60Asee pages 57-58
• Modular fuseblocks - see page 67

Quick Acting
Ampere Ratings: 1-600A
Voltage Rating: 600Vac (or less)
Current Limiting
Interrupting Rating: 200,000A RMS Sym.
Agency Information: Std. 248-8, Class J
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class J dimensional data.
Catalog Numbers
JKS-1

JKS-15

JKS-70

JKS-225

JKS-2

JKS-20

JKS-80

JKS-250

JKS-3

JKS-25

JKS-90

JKS-300

JKS-4

JKS-30

JKS-100

JKS-5

JKS-35

JKS-110

JKS-6

JKS-40

JKS-125

JKS-8

JKS-45

JKS-10

JKS-50

JKS-12

JKS-60

JKS-200

Fuse Reducers for J Dimension Fuses

JKS-350

Clip
Size
60A

Fuse
Size
30A

Cat.
No.
(Pair)
J63

Weight
Carton*
(lbs)
0.38

Clip
Size
400A

Fuse
Size
100A

Cat.
No.
(Pair)
J41

JKS-400

100A

30A

J13

1.73

400A

200A

J42

2.75

JKS-450

100A

60A

J16

1.85

600A

400A

J64

3.55

JKS-150

JKS-500

200A

60A

J26

2.55

600A

200A

J62

3.55

JKS-175

JKS-600

200A

100A

J21

1.36

—

—

—

*Carton quantity—10 pair.

Carton Quantity and Weight
Ampere
Ratings
1-30
35-60
70-100
110-200
225-400
450-600

Carton
Qty.
10
10
5
1
1
1

Weight*
Lbs.
0.95
1.175
0.28
0.86
1.78
3.07

Kg.
0.43
0.53
0.13
0.39
0.81
1.39

*Weight per carton.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1026 (1-60A), 1027 (70-600A)

18

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Weight
Carton*
(lbs)
4.90

—

®

Electrical - Power Fuses

Bussmann

T-Tron® Very Fast Acting, Class T Fuses
JJN

JJS

Very Fast Acting
Ampere Ratings: 1-1200A
Voltage Rating: 300Vac (or less),
(15-600A 160Vdc; 601-1200 170Vdc)
Current Limiting
(curves on page 208)
Interrupting Rating: 200,000A RMS Sym.
(20,000A dc @ 160Vdc & 100,000A dc @ 170Vdc)
Agency Information: Std. 248-15, Class T
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class T dimensional data.

Very Fast Acting
Ampere Ratings: 1-800A
Voltage Rating: 600Vac (or less)
Current Limiting (curves on
page 208)
Interrupting Rating: 200,000A
RMS Sym.
Agency Information: Std. 24815, Class T
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-02, File 53787
Dimensions: See pages 2-3 for Class T dimensional data.

Catalog Numbers

Catalog Numbers

JJN-1
JJN-2
JJN-3
JJN-6
JJN-10
JJN-15
JJN-20
JJN-25
JJN-30

JJN-35
JJN-40
JJN-45
JJN-50
JJN-60
JJN-70
JJN-80
JJN-90
JJN-100

JJN-110
JJN-125
JJN-150
JJN-175
JJN-200
JJN-225
JJN-250
JJN-300
JJN-350

JJN-400
JJN-450
JJN-500
JJN-600
JJN-700
JJN-800
JJN-1000
JJN-1200

JJS-1
JJS-2
JJS-3
JJS-6
JJS-10
JJS-15
JJS-20
JJS-25

JJS-30
JJS-35
JJS-40
JJS-45
JJS-50
JJS-60
JJS-70
JJS-80

JJS-90
JJS-100
JJS-110
JJS-125
JJS-150
JJS-175
JJS-200
JJS-225

JJS-250
JJS-300
JJS-350
JJS-400
JJS-450
JJS-500
JJS-600
JJS-800

Carton Quantity and Weight
Carton Quantity and Weight
Ampere
Ratings
1-30
35-60
70-100
110-200
225-400
450-600
700-800
1000-1200

Carton
Qty.
10
10
5
1
1
1
1
1

Weight*
Lbs.
0.12
0.23
0.36
0.14
0.25
0.44
0.80
1.45

Kg.
0.054
0.104
0.163
0.063
0.113
0.200
0.363
0.658

*Weight per carton.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1025

Recommended fuseblocks/fuseholders for
Class T 300V fuses
• Open fuseblocks - see pages 59-60
• Modular fuseblocks - see page 67

Ampere
Ratings
1-30
35-60
70-100
110-200
225-400
450-600
800

Carton
Qty.
10
10
5
1
1
1
1

Weight*
Lbs.
0.33
0.82
0.51
0.192
0.46
0.85
1.65

Kg.
0.149
0.371
0.231
0.087
0.208
0.385
0.748

*Weight per carton.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1029

Recommended fuseblocks/fuseholders for
Class T 600V fuses
• Open fuseblocks - see pages 61-62
• Modular fuseblocks - see page 67

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

19

®

Electrical - Power Fuses

Bussmann

Time-Delay Class G Fuses
Physical Size:
Fuse (Amps)
A
(Length)

(Length)

SC-⁄Ω™ to -15

1.319

SC-20

1.419

SC-25 to -30

1.639

SC-35 to -60

2.259

.41"
(10.3mm)

SC
Fast Acting (⁄Ω™-6A), Class G
Time-Delay (7-60A), Class G
Construction: Melamine Tube
Ampere Ratings: ⁄Ω™-60A
Voltage Rating: ⁄Ω™-20: 600Vac/170Vdc
25-60: 480Vac/300Vdc (only UL)
Interrupting Rating: 100,000A RMS Sym., 10,000A dc
Agency Information: Std. 248-5, Class G, UL Listed,
Guide JDDZ, File E4273
CSA Certified, Class 1422-01, File 53787
Catalog Symbol & Current Ratings
SC-⁄Ω™

SC-6

SC-25

SC-1

SC-7

SC-30

SC-1⁄Ω™

SC-8

SC-35

SC-2

SC-9

SC-40

SC-2⁄Ω™

SC-10

SC-45

SC-3

SC-12

SC-50

SC-4

SC-15

SC-60

SC-5

SC-20

—

Carton Quantity and Weight
Ampere
Ratings

Carton
Qty.

Weight*
Lbs.

Kg.

⁄Ω™-15

4

0.06

0.03

20

4

0.06

0.03

25-30

2

0.04

0.02

35-60

2

0.08

0.03

• Compact branch-circuit units with high interrupting rating
and current limitation.
• With a 600 volt rating, they can be used in 120/208,
120/240 and 277/480 volt circuits.
• Length variations relative to case size make the “rejection”
type fuses.
• SC fuses with ampere ratings above 6 amps have a degree
of overload time-delay which permits them to pass temporary overloads. At 200% load, they have a minimum opening time of 12 seconds.

Recommended fuseblocks/fuseholders
for Class G
• Open fuseblocks - see page 64
• Panel-mount fuseholders - see page 78
• In-line fuseholders - see page 80

*Weight per carton.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1024 (0-60)

20

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Low-Peak® Time-Delay, Class CC Fuses

20
25
30

3
3⁄Ω™
4
4⁄Ω™
6
8
10
12
15

⁄Ω™
flꭧ
°Ω¡º
1
1⁄Ω¢

Time Current Characteristics—Average Melt
AMPERE
RATING

200
100

10

LP-CC Low-Peak Fuse
Time-Delay Current Limiting,
Class CC - Rejection Type
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑
(10.3mm ≈ 38.1mm)
Ampere Ratings: ⁄Ω™ - 30A
Voltage Rating: 600Vac (or less), 300Vdc (⁄Ω™-2°Ω¡ºA
& 20-30A), 150Vdc (3-15A)
Interrupting Rating: 200,000A RMS Sym; 20,000A dc
Construction: Melamine Tube
Agency Information: Std. 248-4, Class CC
UL Listed, Guide JDDZ, File E4273
CSA Certified; Class 1422-02, File 53787

TIME IN SECONDS

®

1

.1

Catalog Symbol

LP-CC-°Ω¡º

LP-CC-3

LP-CC-9

LP-CC-1

LP-CC-3¤Ω¡º

LP-CC-10

LP-CC-1⁄Ω•

LP-CC-3⁄Ω™

LP-CC-12

LP-CC-1⁄Ω¢

LP-CC-4

LP-CC-15

LP-CC-1›Ω¡º

LP-CC-4⁄Ω™

LP-CC-20

LP-CC-1⁄Ω™

LP-CC-5

LP-CC-25

LP-CC-1flꭧ

LP-CC-5flꭧ

LP-CC-30

LP-CC-1°Ω¡º

LP-CC-6

LP-CC-2

LP-CC-6⁄Ω¢

LP-CC-2⁄Ω¢

LP-CC-7

Recommended fuseblocks/fuseholders for
Class CC 600V fuses
• Open fuseblocks - see page 64
• Finger-safe fuseholders - see pages 41-44, 65
• Panel-mount fuseholders - see page 78
• In-line fuseholders - see page 80

.01

1000

LP-CC-8

100

LP-CC-7⁄Ω™

LP-CC-2°Ω¡º

10

LP-CC-2⁄Ω™

LP-CC-flꭧ

1

LP-CC-⁄Ω™

.4

600Vac

CURRENT IN AMPERES

Current-Limiting Effects
Prospective ShortCircuit Current

*Let-Thru Current (Apparent RMS Symmetrical)
1⁄Ω¢ A

2°Ω¡ºA

15A

25A

30A

1000

100

135

240

20A
305

380

435

3000

140

210

350

440

575

580

5000

165

255

420

570

690

710

10,000

210

340

540

700

870

1,000

20,000

260

435

680

870

1,090

1,305

30,000

290

525

800

1,030

1,300

1,520

40,000

315

610

870

1,150

1,390

1,700

50,000

340

650

915

1,215

1,520

1,820

60,000

350

735

1,050

1,300

1,650

1,980

80,000

390

785

1,130

1,500

1,780

2,180

100,000

420

830

1,210

1,600

2,000

2,400

200,000

525

1,100

1,600

2,000

2,520

3,050

*RMS Symmetrical Amperes Short-Circuit
NOTE: To calculate Ip (Ipeak) multiply IRMS value ≈ 2.3.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1023 (0-30)
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

21

®

Electrical - Power Fuses

Bussmann

Class CC Rejection-Type Fuses

FNQ-R

KTK-R Limitron® Fuse

Time-Delay, Rejection Type
Branch Circuit Fuse
Class CC
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm)
Construction: Melamine Tube
Ampere Ratings: ⁄Ω¢-30A.
Voltage Rating: 600Vac or less
Interrupting Rating: 200,000A RMS Sym.
Agency Information: Std. 248-4, Class CC
UL Listed, Guide JDDZ, File E4273
CSA Certified, Class 1422-01, File 53787

Fast Acting; Branch Circuit Fuse
Class CC - Rejection Feature
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm)
Construction: Melamine Tube
Ampere Ratings: ⁄Ω¡º-30A.
Voltage Rating: 600Vac (or less).
Interrupting Rating: 200,000A RMS Sym.
Agency Information: Std. 248-4, Class CC
UL Listed, Guide JDDZ, File E4273
CSA Certified, File 53787, Class 1422-02

Catalog Symbol & Current Ratings

600Vac

Catalog Symbol & Current Ratings
KTK-R-⁄Ω¡º

KTK-R-1

FNQ-R-⁄Ω¢

FNQ-R-1flꭧ

FNQ-R-7

KTK-R-⁄Ω•

KTK-R-1⁄Ω™

KTK-R-8

FNQ-R-‹Ω¡º

FNQ-R-1°Ω¡º

FNQ-R-7⁄Ω™

KTK-R-¤Ω¡º

KTK-R-2

KTK-R-9

FNQ-R-›Ω¡º

FNQ-R-2

FNQ-R-8

KTK-R-⁄Ω¢

KTK-R-2⁄Ω™

KTK-R-10

FNQ-R-⁄Ω™

FNQ-R-2⁄Ω¢

FNQ-R-9

KTK-R-‹Ω¡º

KTK-R-3

KTK-R-12

FNQ-R-flꭧ

FNQ-R-2⁄Ω™

FNQ-R-10

KTK-R-›Ω¡º

KTK-R-3⁄Ω™

KTK-R-15

FNQ-R-‹Ω¢

FNQ-R-2°Ω¡º

FNQ-R-12

KTK-R-⁄Ω™

KTK-R-4

KTK-R-20

FNQ-R-°Ω¡º

FQN-R-3

FNQ-R-15

KTK-R-flꭧ

KTK-R-5

KTK-R-25

FNQ-R-1

FNQ-R-3¤Ω¡º

FNQ-R-17⁄Ω™

KTK-R-‹Ω¢

KTK-R-6

KTK-R-30

FNQ-R-1⁄Ω•

FNQ-R-3⁄Ω™º

FNQ-R-20

FNQ-R-1⁄Ω¢

FNQ-R-4

FNQ-R-25

FNQ-R-1‹Ω¡º

FNQ-R-5

FNQ-R-1›Ω¡º

FNQ-R-6

FNQ-R-30
—

FNQ-R-1⁄Ω™

FNQ-R-6⁄Ω¢

—

600Vac

KTK-R-7

Time-Current Curves on page 226.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Time-Current Curves on page 225.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1014

Data Sheet: 1015

Recommended fuseblocks/fuseholders for
Class CC 600V fuses
• Open fuseblocks - see page 64
• Finger-safe fuseholders - see pages 41-44, 65
• Panel-mount fuseholders - see page 78
• In-line fuseholders - see page 80

22

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

⁄‹Ω£™∑ ≈ 1‹Ω•∑ Supplementary Fuses

BBS

KTQ

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1‹Ω•∑ (10.3mm ≈ 35mm)
Construction: Fibre Cartridge
Interrupting Rating: 10,000A RMS Sym.
Ampere Ratings: ⁄Ω¡º-30A
Voltage Rating: 600Vac (⁄Ω¡º-5A), 250Vac (6-10A),
48Vac (12-30A)
Agency Information: Std. 248-14
UL Listed, 0-5A/600V, Guide JDYX, File E19180
CSA Certified, 0-5A/600V, Class 1422-01, File 53787

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1‹Ω•∑ (10.3mm ≈ 34.9mm)
Construction: Fibre Cartridge
Ampere Ratings: 1-6A
Voltage Rating: 600Vac
Interrupting Rating: 10,000A RMS Sym.
Agency Information: Std. 248-14
UL Recognized, 4-6A, Guide JDYX2, File E19180
Catalog Symbol & Current Ratings
600Vac
KTQ-1

Catalog Symbol & Current Ratings
600Vac
BBS-⁄Ω¡º
BBS-¤Ω¡º
BBS-⁄Ω¢
BBS-›Ω¡º
BBS-⁄Ω™
BBS-flꭧ
BBS-‹Ω¢
BBS-°Ω¡º
BBS-1
BBS-1⁄Ω™
BBS-1flꭧ
BBS-1°Ω¡º
BBS-2
BBS-3
BBS-4
BBS-5

250Vac
BBS-6
BBS-7
BBS-8
BBS-10
—
—
—
—
—
—
—
—
—
—
—
—

48Vac
BBS-12
BBS-15
BBS-20
BBS-25
BBS-30
—
—
—
—
—
—
—
—
—
—
—

KTQ-1flꭧ
KTQ-2
KTQ-3
KTQ-4
KTQ-5
KTQ-6

Data Sheet: 2045
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 2010 (0-30A)
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Recommended fuseblocks/fuseholders for
13/32” x 1-1/2” fuses
• Open fuseblocks - see page 64, 66
• Finger-safe fuseholders - see pages 41-44, 65
• Panel-mount fuseholders - see page 78-79
• In-line fuseholders - see page 80-81

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

23

®

Bussmann

Electrical - Power Fuses

⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Supplementary Fuses

BAF

BAN

KTK and KLM

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑
(10.3mm ≈ 38.1mm)
Construction: Fibre Tube;
Nickel Plated Brass Endcaps
Voltage Rating: 250Vac (¤Ω¡º-15A),
125Vac (20-30A)
Interrupting Rating: 10,000A at
125Vac
Agency Information: Std. 248-14
UL 0-15/250V, Guide JDYX,
File E19180
CSA Certified, 0-15/250V,
Class 1422-01, File 53787

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑
(10.3mm ≈ 38.1mm) - 5AG
Construction: Fibre Tube
Voltage Rating: 250Vac
Interrupting Ratings: Military Tested
35A (1.1.-3.5A)
100A (3.6-10A)
200A (10.1-15A)
750A (15.1-30A)

Catalog Symbol & Current Ratings

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm)
Construction: Melamine Tube;
Nickel Plated Brass Endcaps
Voltage Rating:
KTK - 600Vac or less
KLM - ⁄Ω¡ º -⁄Ω• A: 500Vac/600Vdc
¤Ω¡ º -10A: 500Vac/dc,
12-30A: 500Vac/600Vdc
Interrupting Rating:
100,000A - KTK; 10,000A - KLM,
RMS SYM. (UL)
Agency Information: Std. 248-14
KTK-UL Listed, Guide JDYX,
File E19180
KLM-UL Recognized, Guide JFHR2,
File E56412
CSA Certified, File 53787, Class
1422-01, HRC-Misc

250V IR*
BAF-¤Ω¡ º

250V IR*
BAF-1⁄Ω™

BAF-⁄Ω¢

BAF-1°Ω¡ º

250V IR*
BAF-6⁄Ω¢

BAF-7
IR
IR BAF-2 100A BAF-8
35A BAF-2⁄Ω™
BAF-9

125V
BAF-20

Catalog Symbol & Current Ratings

IR
BAF-25 10000A
IR
200A BAF-30

250V

250V

250V

BAN-1

BAN-5

BAN-12

250V
BAN-30

BAN-2

BAN-6

BAN-15

—

BAN-3

BAN-8

BAN-20

—

BAN-4

BAN-10

BAN-25

—

Recommended Fuseblocks

BAF-°Ω¡ º

BAF-3

BAF-10

—

BAF-1

BAF-4

BAF-12

—

Amps

Poles

Terminal Type
Screw
Pressure
with
Plate w/
Quick
Quick
Connect
Connect

—

BAF-5

—

⁄Ω¡ º

1

BM6031SQ

BM6031PQ

BM6031B

KTK-¤Ω¡ º

KTK-1⁄Ω¢

KTK-6

KTK-20

—

BAF-6

—

to

2

BM6032SQ

BM6032PQ

BM6032B

KTK-⁄Ω¢

KTK-1⁄Ω™

KTK-7

KTK-25

30

3

BM6033SQ

BM6033PQ

BM6033B

KTK-‹Ω¡ º

KTK-2

KTK-7⁄Ω™

KTK-30

KTK-›Ω¡ º

KTK-2⁄Ω™

KTK-8

—

KTK-⁄Ω™

KTK-3

KTK-9

—

KTK-flΩ¡ º

KTK-3⁄Ω™

KTK-10

—

BAF-⁄Ω™
BAF-flΩ¡ º

IR
IR
200A BAF-15 750A
—

—

*All have interrupting rating of 10,000A at 125V.

Data Sheet: 2011 (0-30)

Data Sheet: 2046 (0-30)

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings
600Vac - UL Listed and C.S.A.
Box
Lug

KTK-⁄Ω¡ º

KTK-‹Ω¢

KTK-4

KTK-⁄Ω•

KTK-1

KTK-5

KTK-15

*500Vac/dc - UL Recognized and C.S.A.

Recommended fuseblocks/fuseholders for
13/32” x 1-1/2” fuses
• Open fuseblocks - see page 64, 66
• Finger-safe fuseholders - see pages 41-44, 65
• Panel-mount fuseholders - see page 78-79
• In-line fuseholders - see page 80-81

KLM-⁄Ω¡ º

KLM-‹Ω¢

KLM-5

KLM-20

KLM-⁄Ω•

KLM-1

KLM-6

KLM-25

KLM-¤Ω¡ º

KLM-1⁄Ω™

KLM-8

KLM-30

KLM-⁄Ω¢

KLM-2

KLM-10

—

KLM-‹Ω¡ º

KLM-3

KLM-12

—

KLM-⁄Ω™

KLM-4

KLM-15

—

*KLM-(⁄Ω¡ º-⁄Ω• & 12-30): 500VAC/600Vdc

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: KTK-1011
KLM-2020

24

KTK-12

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Supplementary Fuses

FNM Fusetron® Fuse

FNQ

Time-Delay
Physical Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5 AG)
(10.3mm ≈ 38.1mm)
Construction: Fibre Tube
Ampere Ratings: ⁄Ω¡ º - 30A.
Voltage Rating: 250Vac (or less).
Interrupting Rating: See Table Below.
Agency Information: Std. 248-14
UL Listed, 0-10/250V; 12-15/125V;
File E19180, Guide JDYX
CSA Certified, 1-10/250V; Class 1422-01, 12-15/125V;
File 53787
NOTE: For 250V applications from 12-30A use FNW.

Time-Delay
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5 AG)
(10.3mm ≈ 38.1mm)
Construction: Fibre Tube
Ampere Ratings: ⁄Ω¡ º - 30A
Voltage Rating: 500Vac or less
Interrupting Rating: 10,000A RMS Sym.
Agency Information: Std. 248-14
UL Listed, Guide JDYX, File E19180
CSA Certified, Class 1422-01, File 53787

Catalog Symbol & Current Ratings

FNQ-⁄Ω¡º

FNQ-°Ω¡º

FNQ-3¤Ω¡º

FNQ-8

FNQ-⁄Ω•

FNQ-1

FNQ-3⁄Ω™

FNQ-9

FNQ-⁄fiΩ¡ºº

FNQ-1⁄Ω•

FNQ-4

FNQ-10

FNQ-‹Ω¡§

FNQ-1⁄Ω¢

FNQ-4⁄Ω™

FNQ-12

FNQ-¤Ω¡º

FNQ-1⁄Ω™

FNQ-5

FNQ-14

FNQ-⁄Ω¢

FNQ-1flꭧ

FNQ-5flꭧ

FNQ-15

FNQ-‹Ω¡º

FNQ-2

FNQ-6

FNQ-20

FNQ-›Ω¡º

FNQ-2⁄Ω¢

FNQ-6⁄Ω¢

FNQ-25

FNQ-⁄Ω™

FNQ-2⁄Ω™

FNQ-7

FNQ-30

FNQ-flꭧ

FNQ-3

—

—

250Vac
FNM-⁄Ω¡º
FNM-⁄Ω•
FNM-⁄fiΩ¡ºº
FNM-¤Ω¡º
FNM-⁄Ω¢
FNM-‹Ω¡º
FNM-›Ω¡º
FNM-⁄Ω™
FNM-flꭧ
FNM-‹Ω¢
FNM-°Ω¡º
FNM-1
—
250Vac

IR

35A
@ 250Vac
10,000A
@ 125Vac

FNM-1⁄Ω•
FNM-1⁄Ω¢
FNM-1›Ω¡º
FNM-1⁄Ω™
FNM-1flꭧ
FNM-1°Ω¡º
FNM-2
FNM-2⁄Ω¢
FNM-2⁄Ω™
FNM-2°Ω¡º
FNM-3
FNM-3¤Ω¡º
FNM-3⁄Ω™

IR

125Vac

200A
@ 250Vac
10,000A
@ 125Vac

FNM-12
FNM-15
—
—
32Vac
FNM-20
FNM-25
FNM-30
—
—

FNM-4
FNM-4⁄Ω™
FNM-5
FNM-5flꭧ
FNM-6
FNM-6⁄Ω¢
FNM-7
FNM-8
FNM-9
FNM-10

250Vac

IR

100A
@ 250Vac
10,000A
@ 125Vac

Catalog Symbol & Current Ratings
500Vac

Data Sheet: 1012

IR

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

10,000A
@ 125Vac

Recommended fuseblocks/fuseholders for
13/32” x 1-1/2” fuses
• Open fuseblocks - see page 64, 66
• Finger-safe fuseholders - see pages 41-44, 65
• Panel-mount fuseholders - see page 78-79
• In-line fuseholders - see page 80-81

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 2028
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

25

®

Bussmann

Electrical - Power Fuses

Plug Fuses

W Series

SL and TL Series

S and T Series

Fast Acting
Ampere Ratings: ⁄Ω™ - 12A
Voltage Rating: 125Vac
IR: 10,000A RMS Sym.
Element is a simple fusible, metal link.
For general purpose circuit protection.
Quickly opens when short-circuit or
overload occurs. Use for lighting and
other non-motor circuits. Edison base.
Agency Information: Std. 248-11
UL Listed, Guide JEFV, File E12112

Time-Delay, Loaded Link
Ampere Ratings: 15 - 30A
Voltage Rating: 125Vac
IR: 10,000A RMS Sym.
Heat absorbing metal bead on element link for time-delay. Passes motor
overload starting currents without
needlessly opening.
Edison base (TL), Rejection base (SL).
Agency Information: Std. 248-11
UL Listed, Guide JEFV, File E12112

Time-Delay, Dual-Element
Ampere Ratings:
Type S: ⁄Ω¢ - 30A
Type T: ‹Ω¡º - 30A
Voltage Rating: 125Vac
IR: 10,000A RMS Sym.
For all-purpose application. Like two
fuses in one. A simple link element for
short-circuits and dangerous overloads
plus a series-connected element which
lets the harmless overload starting currents of motors pass without opening.
Uses less energy; operates cooler;
provides superior protection.
Edison base (T), Rejection base (S).
Agency Information: Std. 248-11
Type S: UL Listed (0-6⁄Ω¢) Guide JFHR,
File E56412 (7-30A) Guide JEFV,
File E12112;
CSA Certified, Class 1423-01, File 53787

Type W
W-⁄Ω™
W-1
W-1°Ω¡º
W-2
W-2⁄Ω™
W-3

W-4
W-5
W-6
W-6⁄Ω™
W-7
W-8

W-10
W-12

Type SL
SL-15
SL-20
SL-25
SL-30

Type TL
TL-15
TL-20
TL-25
TL-30

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Type S
S-⁄Ω¢
S-‹Ω¡º
S-›Ω¡º
S-⁄Ω™
S-flꭧ
S-°Ω¡º
S-1
S-1⁄Ω•
S-1⁄Ω¢

S-1›Ω¡º
S-1flꭧ
S-1°Ω¡º
S-2
S-2⁄Ω¢
S-2⁄Ω™
S-2°Ω¡º
S-3
S-3¤Ω¡º

S-3⁄Ω™
S-4
S-4⁄Ω™
S-5
S-5flꭧ
S-6
S-6⁄Ω¢
S-7
S-8

S-9
S-10
S-12
S-14
S-15
S-20
S-25
S-30

Type T
T-‹Ω¡º
T-›Ω¡º
T-⁄Ω™
T-flꭧ
T-°Ω¡º
T-1
T-1⁄Ω•
T-1⁄Ω¢
T-1›Ω¡º

T-1flꭧ
T-1°Ω¡º
T-2
T-2⁄Ω¢
T-2⁄Ω™
T-2°Ω¡º
T-3
T-3¤Ω¡º
T-3⁄Ω™

T-4
T-4⁄Ω™
T-5
T-5flꭧ
T-6
T-6⁄Ω¢
T-7
T-8
T-9

T-10
T-12
T-14
T-15
T-20
T-25
T-30

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 1036

26

Data Sheet: 1033 (SL) & 1035 (TL)

Data Sheet: 1032 (S)
& 1034 (T)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Electrical - Power Fuses

Bussmann

Plug Fuses
Dual-Element Fustat® Fuses and Adaptors for Small
Motor Protection.
(Both Motor Running and Short-Circuit Protection)

Fustat Fuse Adaptors
Fustat Adaptors (various ampere ratings) screw into the
“Edison” Thread fuse sockets of standard household fuse
boxes. Adaptors serve the purpose of preventing the wrong
size fuse from being used.
Carton
Catalog Number Prefix

Ampere Rating

SA(Branch Circuits)

15, 20, 30

SA(Single Motor Circuits)

1, 1⁄Ω¢, 1flΩ¡º, 2, 2⁄Ω™,
3¤Ω¡º, 4, 5, 6⁄Ω¢, 8, 10

ENA

Edison base neutral

Qty.

4

Wt.
0.03
(lbs)

Adaptor

Accepts Fuses

SA-1

S-1 or smaller

SA-1-1/4

S-1-1/4 or smaller

SA-1-6/10

S-1-6/10 or smaller

SA-2

S-2 or S-1-8/10

SA-2-1/2

S-2-1/2 to S-1-8/10

SA-3-2/10

S-3-2/10 to S-1-8/10

SA-4

S-4 to S-3-1/2

SA-5

S-5 to S-3-1/2

SA-6-1/4

S-6-1/4 to S-3-1/2

SA-8

S-8 to S-7

SA-10

S-10 to S-7

SA-15

S-15 to S-7

SA-20

S-20

SA-30

S-30 to S-20

Branch Circuit Protection
Adaptor

Accepts Fuses

SA-15

S-15 to S-7

SA-20

S-20

SA-30

S-25

SA 30

S-30 to S-20

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

27

®

Electrical - Power Fuses

Bussmann

Cable Limiters & Welder Limiters

K Series

68000 & 64000 Series

Cable Limiters
Interrupting Rating: 200,000A, 600Vac
RMS Symmetrical
UL Listing: KDM, KDR, KDP and KFM

Welder Limiters for Class H and J Fuseholders
Voltage Rating: 600Vac or less
Interrupting Rating: 200,000 Amps RMS Symmetrical
Catalog Symbol & Current Ratings
Type
Fuseholder

Copper Cable Limiter — 600 Volts
Catalog
Symbol

Cable
Size

Catalog
Symbol

Cable
Size

KCY

#4

KCF

4/0

KCZ

#3

KCH

250 MCM

KCA

#2

††KCJ

350 MCM

KCB

#1

†† †KCM

500 MCM

KCC

1/0

KCV

600 MCM

††KCD

2/0

††KCR

750 MCM

KCE

3/0

KCS

1000 MCM

Tubular Terminals

Class H

Tubular Terminal and Offset Bolt-Type Terminal
KQV

#12

KDD

2/0

KQT

#10

KDE

3/0

KFZ

#8

KDF

4/0

KIG

#6

KDH

250 MCM

KDY

#4

††KDJ

350 MCM

KDA

#2

†KDM1

500 MCM

KDB

#1

KDU

600 MCM

KDC

1/0

††KDR1

750 MCM

Compression Connector Rod Terminal and Tubular Terminal
KEX

4/0

KFH-A

250 MCM

KQO

350 MCM

††KDT

500 MCM

Class J

Catalog
Number

Amp Rating
(Nominal)

68150

150

68200

200

Carton
Quantity

Weight Each
Lbs.
Kg.

1

1.40

0.63

1

2.75

1.25

68300

300

68400

400

68600

600

1

4.25

1.92

64200

200

1

1.00

0.45

64300

300

1

1.75

0.79

64400

400

1

1.75

0.79

64600

600

1

3.50

1.59

• Current-limiting devices designed specially for use on
welder circuits only.
• Time-current characteristics are designed to hold on the
intermittent overloading encountered in welder operation,
while providing short-circuit protection to the circuit and
equipment.
• Welder limiters have excess current capacity in the operating range as needed for this type of service.
• Because of the special characteristics of the welder limiters,
they are not intended for application on general-use circuits.

*Center Bolt-Type Terminal and Off-Set Bolt-Type Terminal
KPF

4/0

KDP1

500 MCM

KFT

250 MCM

KFM1

750 MCM

KEW

350 MCM

†Available with molded rubber boots. Add “–B” to end of part number.
††Available with shrink tube “_V” suffix.
*Copper or aluminum cable; sizes of all other limiters pertain to copper only.
UL Listed (File E90818)

1

• Crimp Tool: TBM-14M
• Die: 15506 KDM
15515 KDR
Data Sheet: 1042

28

Data Sheet: 1045
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Bussmann

Electronic – PC Board and Small Dimension Fuses

5mm ≈ 15mm Fuses

C515 (Axial Leads)
C519

C518 (Axial Leads)
C520

Time-Delay
Physical Size:
0.197∑ ≈ 0.591∑ (5mm ≈ 15mm)
Construction: Glass Tube
Agency Information:
UL Listing File E19180, Guide JDYX
125mA-250mA and 375mA-3A
CSA Certification File LR65063,
Class 1422-01, 125mA-250mA and
375mA-3A
UL Recognized, File E19180,
Guide JDYX2, 350mA and 3.5A-7A

Fast-Acting
Physical Size:
0.197∑ ≈ 0.591∑ (5mm ≈ 15mm)
Construction: Glass Tube
Agency Information:
UL Listing File E19180, Guide JDYX
CSA Certification File LR65063,
Class 1422-01
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Electrical Characteristics
Current
Rating

Rated
Voltage
ac

Electrical Characteristics

Interrupting
Rating

Current
Rating

125mA

35A/250V 10kA/125V

100mA

250mA

p.f. = 0.7 - 0.8

125mA

350mA

35A/250V 10kA/125V

250mA

25A/600V p.f. = 0.7 - 0.8

375mA

500mA

35A/250V

750mA

600mA

10kA/125V

1A

250V

Interrupting
Rating

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Electrical Characteristics
Current
Rating

Max. Rated
Voltage
ac

Interrupting
Rating
p.f. = 1.0

35A/250V
10kA/125V

3A

350V*

p.f. = 0.7 - 0.8

100A/250Vac
p.f. = 0.7 - 0.8
10kA/125Vac
p.f. = 0.7 - 0.8

250V

*350Vac/100A is UL Recognized

1.5A

p.f. = 0.7 - 0.8

1A

2A

1.25A

2.5A

1.5A

3A

100A/250V
10kA/125V
p.f. = 0.7 - 0.8

1.6A

100A/250V

3.5A

2A

10kA/125V

4A

200A/250V 10kA/125V5A

p.f. = 0.7 - 0.8

5A

p.f. = 0.7 - 0.8

2.25A

Fast-Acting, Light Ballast
Protection
Physical Size:
0.197∑ ≈ 0.591∑ (5mm ≈ 15mm)
Construction: Ceramic
Agency Information:
UL Listing File E19180, Guide JDYX
CSA Certification File LR65063,
Class 1422-01
UL Recognized, File E19180,
Guide JDYX2

100A/350Vac

500mA

375mA

750mA

Rated
Voltage
dc

C517 (Axial Leads)

2.5A
3A
3.5A
4A
5A

125V

400A/125V
p.f. = 1.0

7A

Data Sheet: 2006 (C515)
& 2007 (C519)

Data Sheet: 2026 (C518)
& 2027 (C520)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 2025

29

®

Bussmann

Electronic – PC Board and Small Dimension Fuses

5mm ≈ 20mm — IEC Standards
GDA
GDA-V (Axial
Leads)

GDB
GDB-V (Axial
Leads)

GDC
GDC-V (Axial
Leads)

Fast-Acting,
High Breaking
Capacity
Physical Size:
0.197∑ ≈ 0.788∑
(5mm ≈ 20mm)
Construction:
Ceramic Tube
End caps: Nickel plated brass
Voltage Rating: 250Vac or less
Interrupting Rating: 1500A @
250Vac
Agency Information:
UL Recognized, Guide JDYX2,
File E19180, 50mA and 315mA-6.3A
SEMKO Approval 50mA, 200mA and
315mA-6.3A
IEC 127-SI
VDE Approval 1.25A-6.3A

Fast-Acting,
Low Breaking
Capacity
Physical Size:
0.197∑ ≈ 0.788∑
(5mm ≈ 20mm)
Construction:
Glass Tube
End caps: Nickel plated brass
Voltage Rating: 250Vac or less
Interrupting Rating: 35A @ 250Vac
Agency Information:
Designed to IEC (Pub 127) Sheet II
British Standard Approval
SEMKO Approval
VDE Approval, IMQ
UL Recognized, Guide JDYX2,
File E19180, 32mA-6.3A

Time Delay,
Low Breaking
Capacity
Physical Size:
0.197∑ ≈ 0.788∑
(5mm ≈ 20mm)
Construction:
Glass Tube
End caps: Nickel plated brass
Voltage Rating: 250Vac or less
Interrupting Rating: 35A @ 250Vac
Agency Information:
Designed to IEC (Pub 127) Sheet III
British Standard Approval
SEMKO Approval
VDE Approval, IMQ
UL Recognized, Guide JDYX2,
File E19180, 32mA-6.3A

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Electrical Characteristics

Electrical Characteristics
Current
Rating

I2t

50mA
63mA
80mA
100mA
125mA
160mA
200mA
250mA
315mA
400mA
500mA
630mA
800mA
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A

0.0017
0.0005
0.0011
0.0018
0.0037
0.008
0.020
0.027
0.010
0.018
0.038
0.064
0.097
0.480
0.9
1.9
2.0
3.9
8.1
14
25
48

Data Sheet: 2014

30

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Max Voltage
Drop (mV)
9000
3300
2600
2300
1900
1600
1350
1300
1400
1200
1050
1200
490
230
200
180
205
190
160
160
155
150

Current
Rating

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Electrical Characteristics
Max Voltage
Drop (mV)

Current
Rating

I2t

32mA
0.000047
10000
40mA
0.00011
8000
50mA
0.00020
3200
63mA
0.00057
2500
80mA
0.0012
2200
100mA
0.003
2100
125mA
0.005
2000
160mA
0.008
1950
200mA
0.016
1600
250mA
0.028
1400
315mA
0.058
1150
400mA
0.018
950
500mA
0.018
220
630mA
0.035
220
800mA
0.067
180
1A
0.60
200
1.25A
0.84
200
1.6A
1.6
190
2A
4.2
160
2.5A
6.1
145
3.15A
13
130
4A
22
120
5A
42
115
6.3A
69
110
8A*
—
—
10A*
—
—
12A*
—
—
16A*
—
—
*IEC Standard 127 Sheet II does not include ratings above
6.3A.

32mA
40mA
50mA
63mA
80mA
100mA
125mA
160mA
200mA
250mA
315mA
400mA
500mA
630mA
800mA
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A

0.0014
0.0034
0.006
0.012
0.015
0.022
0.034
0.052
0.078
0.17
0.41
0.61
0.75
1.3
3.1
3.6
7
10
17
34
56
91
133
270

Data Sheet: 2015

Data Sheet: 2016

I2t*

Max Voltage
Drop (mV)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

1050
920
800
760
580
490
390
320
340
270
250
210
168
158
132
85
80
80
80
80
75
75
75
65

®

Bussmann

Electronic – PC Board and Small Dimension Fuses

5mm ≈ 20mm – N. American Standards
GMA
GMA-V
(Axial Leads)
Fast Acting
Physical Size:
0.197∑ ≈ 0.788∑
(5mm ≈ 20mm)
Construction:
Glass Tube
End Caps; nickel
plated brass
Agency
Information:
Std. 248-14
UL Listed Guide JDYX, File E19180, 0-6A
UL Recognized, Guide JDYX2,
File E19180, 7-15A
CSA Certified, Class 1422-01,
File E65063, 0-6A

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

GMC
GMC-V
(Axial
Leads)

GMD
GMD-V
(Axial
Leads)

Medium TimeDelay
Physical Size:
0.197∑ ≈ 0.788∑
(5mm ≈ 20mm)
Construction:
Glass Tube
End Caps; nickel
plated brass
Agency Information:
Std. 248-14
UL Listed Guide JDYX, File E19180, 06.3A
UL Recognized, Guide JDYX2,
File E19180, 7-8A
CSA Certified, Class 1422-01,
File 65063, 0-6.3A

Time-Delay
Physical Size:
0.197∑ ≈ 0.788∑
(5mm ≈ 20mm)
Construction:
Glass Tube
End Caps; nickel
plated brass
Agency
Information:
Std. 248-14
UL Listed Guide JDYX, File E19180, 0-3A
UL Recognized, Guide JDYX2,
File E19180, 4A
CSA Certified, Class 1422-01,
File 65063, 0-3A

Electrical Characteristics

Electrical Characteristics

Rated
Voltage
(Vac)

Rated
Voltage
(Vac)

Current
Rating
63mA
100mA
125mA
200mA
250mA
300mA
315mA
500mA
600mA
750mA
800mA
1A
1.25A
1.5A
1.6A
2A
2.5A
3.15A
3.5A
4A
5A
6A
7A
8A
10A
15A

Breaking
Capacity

35A/250V
10kA/125V
p.f. = 0.7 – 0.8

250

100A/250V
10kA/125V
p.f. = 0.7 – 0.8

10kA/125V
p.f. = 0.7 – 0.8
125
200A/125V
p.f. = 1.0
150A/125V
p.f. = 1.0

Data Sheet: 2017

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Current
Rating
63mA
80mA
100mA
125mA
150mA
200mA
250mA
300mA
315mA
400mA
500mA
600mA
630mA
750mA
800mA
1A
1.25A
1.5A
1.6A
2A
2.5A
3A
3.15A
3.5A
4A
5A
6A
6.3A
7A
8A
10A

Breaking
Capacity

35A/250V
10kA/125V
p.f. = 0.7 – 0.8
250

100A/250V
10kA/125V
p.f. = 0.7 – 0.8

Electrical Characteristics
Current
Rating
125mA
150mA
200mA
250mA
300mA
315mA
400mA
500mA
600mA
630mA
750mA
800mA
1A
1.2A
1.25A
1.5A
1.6A
2A
2.5A
3A
4A

Rated
Voltage
(Vac)

Breaking
Capacity

250

100A/250V
10kA/125V
p.f. = 0.7 – 0.8

200A/250V
10kA/125V, p.f. = 1

10kA/125V
p.f. = 0.7 – 0.8
125
200A/125V
p.f. = 1.0

Data Sheet: 2018

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet:2019

31

®

Bussmann

Electronic – PC Board and Small Dimension Fuses

⁄Ω¢ ∑ Diameter ≈ fiΩ• ∑ to 1∑ Lengths

AGA
AGA-V* (Axial Leads)

AGW

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ fiΩ•∑ (1AG)
(6.4mm ≈ 15.9mm)
Construction: Glass Tube
Voltage Rating: See table below.
Agency Information: Std. 248-14
UL File E19180,
UL Listed, Guide JDYX 0-1⁄Ω™ A
UL Recognized, Guide JDYX2 2-12A,

AGX
AGX-V (Axial Leads)*

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ ‡Ω•∑ (7AG)
(6.4mm ≈ 22.2mm)
Construction: Glass Tube
Voltage Rating: 32V
Catalog Symbol & Current Ratings
32Vac
AGW-1

AGW-4

AGW-15

AGW-1⁄Ω™

AGW-5

AGW-20

AGW-2

AGW-6

AGW-25

AGW-2⁄ Ω™

AGW-7⁄Ω™

AGW-30

AGW-3

AGW-10

—

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1∑ (8AG)
(6.4mm ≈ 25.4mm)
Construction: Glass Tube
Voltage Rating: See table below.
Agency Information: Std. 248-14
UL File E19180
UL Listed, Guide JDYX, 0-5A
UL Recognized, Guide JDYX2, 6-20A
CSA File 47233; Class 1422-01, 0-5A
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc. Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings

Catalog Symbol & Current Ratings

250Vac/35A (⁄ Ω∞ºº-⁄Ω™ A), 100A (‹Ω¢ -1⁄Ω™ A)

125Vac/10kA (⁄Ω¡ §-1⁄Ω™ ), 200A (2-5A)

AGX-⁄ Ω∞ºº

AGX-‹Ω¡ §

AGX-‹Ω¢

AGA-⁄Ω¡ §

AGA-⁄Ω™

AGA-2

AGX-⁄Ω™ºº

AGX-¤Ω¡ º

AGX-1

AGA-⁄Ω¡ º

AGA-flΩ¡ º

AGA-2⁄Ω™

AGX-⁄Ω¡ ºº

AGX-⁄Ω¢

AGX-1⁄Ω¢

AGA-⁄ Ω•

AGA-‹Ω¢

AGA-3

AGX-⁄Ω£ ™

AGX-‹Ω¡ º

AGX-1⁄Ω™

AGA-⁄Ω¢

AGA-1

AGA-5

AGX-⁄Ω¡ §

AGX-‹Ω•

AGX-2

AGA-‹Ω•

AGA-1⁄Ω™

—

AGX-⁄Ω¡ º

AGX-›Ω¡ º

—

AGX-⁄Ω•

AGX-⁄Ω™

—

AGX-2⁄Ω™

AGX-4

AGX-6

AGX-3

AGX-5

AGX-7

32Vac/1kA
AGA-6

AGA-10

AGA-25

AGA-7

AGA-15

AGA-30

AGA-7⁄Ω™

AGA-20

125Vac/10kA

—

32 V/1kA
AGX-8

AGX-15

AGX-25

AGX-10

AGX-20

AGX-30

*AGA-V is UL Listed 0-5A, UL Recognized 6-12A

* AGX-V is UL Recognized from 6-20A @ 32Vac

Data Sheet: 2039

32

Data Sheet: 2040

Data Sheet: 2041

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Bussmann

Electronic – PC Board and Small Dimension Fuses

⁄Ω¢ ∑ Diameter ≈ 1∑ Lengths

TDC180

TDC600

FWH

British Household Plug Fuse
Fast/Medium
Physical Size:
⁄Ω¢∑ ≈ 1∑
(6.4mm ≈ 25.4mm)
Construction: Ceramic Tube
End Caps: Silver-plated copper
Agency Information:
BS1362, IEC 269-3A

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1∑
(6.3mm ≈ 25.4mm)
Construction: Ceramic Tube
Voltage Rating: 600Vac
Agency Information:
UL Recognized, Std. 248-14, BS1362

Catalog Symbol & Current Ratings

TDC600-2A

Semiconductor Fuse
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑
(6.3mm ≈ 32mm)
Construction: Ceramic Tube
Voltage Rating:
500Vac/50kA (.25-20A)
500Vac/20kA (25A, 30A)
Agency Information: Std. 248-14
UL Recognized .25-7, 500Vac,
File E91958, Guide JFHR2
UL Recognized 10-30, 500Vac,
File E56412, Guide JFHR2

Catalog Symbol & Current Ratings
TDC600-10A

240Vac
TDC180-1

TDC180-5

TDC180-13

TDC180-2

TDC180-7

—

TDC180-3

TDC180-10

—

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings
FWH-.250A6F

FWH-010A6F

FWH-.500A6F

FWH-12.5A6F

FWH-001A6F

FWH-015A6F

FWH-002A6F

FWH-016A6F

FWH-3.15A6F

FWH-020A6F

FWH-005A6F

FWH-025A6F

FWH-6.30A6F

FWH-030A6F

FWH-007A6F
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 2042

Data Sheet: 2081

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 720038 (Fuse)
Time-Current 35785256, 50955

33

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fast Acting Fuses
TDC10
Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG)
(6.3mm ≈ 32mm)
Construction: Glass Tube
Voltage Rating: See Below
Agency Information:
Conforms to British Standard
BS-2950A, I.R. 10Im@Vm.
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings

AGC
AGC-V (Axial
Leads)

ABC
ABC-V (Axial
Leads)

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG)
(6.3mm ≈ 32mm)
Construction:
Glass Tube
Nickel Plated Brass
End Caps
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Information: Std. 248-14
UL Listed, Guide JDYX, File E19180, 0-10A
UL Recognized, Guide JDYX2,
File E19180, 15-30A
CSA Certification, Class 1422-01,
File 53787

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AB)
(6.3mm ≈ 32mm)
Construction:
Ceramic Tube
Nickel Plated
Brass End Caps
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Information: Std. 248-14
UL Listed, Guide JDYX File E19180, 0-15A
UL Recognized, Guide JDYX2,
File E19180, 20-25A
CSA Certification, Class 1422-01,
File 53787, 0-15A, Class 1422-30,
File 53787, 20-25A

1000Vac

250Vac

TDC10-50mA

TDC10-1.5A

TDC10-60mA

TDC10-2A

TDC10-100mA

TDC10-3A

TDC10-150mA

TDC10-5A

TDC10-250mA

150Vac

750Vac

TDC10-7A

TDC10-500mA

100Vac

500Vac

TDC10-10A

TDC10-750mA

32Vac

Electrical Characteristics

350Vac

TDC10-12A

TDC10-1A

TDC10-15A

Current
Rating

—

TDC10-20A

—

TDC10-25A

Data Sheet: 2043

34

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Rated
Voltage
ac (Max.)

Electrical Characteristics
Interrupting
Rating1
ac

⁄Ω™º
250V
35A
⁄Ω¡ §
250V
35A
⁄Ω¡ º
250V
35A
⁄Ω•
250V
35A
‹Ω¡ §
250V
35A
¤Ω¡ º
250V
35A
⁄Ω¢
t250V
35A
‹Ω¡ º
250V
35A
‹Ω•
250V
35A
›fiΩ¡ ºº
t250V
35A
⁄Ω™
250V
35A
‹Ω¢
250V
35A
1
250V
35A
1⁄Ω¢
250V
100A
1⁄ Ω™
250V
100A
2
250V
100A
2⁄Ω¢
250V
100A
2⁄Ω™
250V
100A
3
250V
100A
4
250V
200A
5
250V
200A
6
250V
200A
7
250V
200A
8
250V
200A
9
250V
200A
10
250V
200A
15
32V
1000A
20
32V
1000A
25
32V
1000A
30
32V
1000A
1Interrupting ratings were measured at 70% – 80% power
factor on AC, and at a time constant described in UL 248.

Data Sheet: 2001

Current
Rating

Rated
Voltage
ac (Max.)

Interrupting
Rating1

dc (Max.)

ac

dc

⁄Ω¢
⁄Ω™
‹Ω¢

250V
250V
250V

125V
125V
125V

35A
35A
35A

10kA
10kA
10kA

1
1⁄Ω™
2

250V
250V
250V

125V
125V
125V

35A
100A
100A

10kA
10kA
10kA

2⁄Ω™
3
4

250V
250V
250V

125V
125V
125V

100A
100A
200A

10kA
10kA
10kA

5
6
7

250V
250V
250V

125V
125V
125V

200A
200A
200A

10kA
10kA
10kA

8
10
15

250V
250V
250V

125V
125V
125V

200A
200A
750A

10kA
10kA
10kA

20
25
30

250V
125V
125V

125V
125V
125V

400A
1000A
1000A

10kA
400A
400A

1Interrupting

ratings were measured at 70% – 80% power
factor on AC, and at a time constant described in UL 248.

Data Sheet: 2000

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fuses
GBB
GBB-V
(Axial Leads)

TDC11

Very Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AB)
(6.3mm ≈ 32mm)
Construction:
Ceramic Cartridge
Nickel Plated
Brass End Caps
Voltage Rating: 250Vac/125Vdc
Interrupting Rating:
200A @ 250Vac
10kA @ 125Vac/dc (1-15A),
200A @ 125Vac/dc (20-30A)
Agency Information: Std. 248-14
UL Recognized, 1-30, 125Vdc/250Vac,
File E56412, Guide JFHR2
CSA Certified, 1-10, 125Vdc/250Vac,
File 53787, Class 1422-01

Time Lag
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG)
(6.3mm ≈ 32mm)
Construction:
Glass Tube
Voltage Rating:
See Below
Interrupting
Rating: 10 times rated
current @ Vm.
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

MDL
MDL-V (Axial
Leads)
Time-Delay
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG)
(6.3mm ≈ 32mm)
Construction:
Glass Tube
Nickel Plated
Brass End Caps
Voltage Rating: See Below
Interrupting Rating: See Below
Agency Information: Std. 248-14
UL Listed, Guide JDYX, File E19180;
⁄Ω¡§ -8A
CSA Certification Class 1422-01,
File 53787, ⁄Ω¡§ -8A
UL Recognized, Guide JDYX2,
File E19180, 8.1-30A
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol and Current Ratings

Electrical Characteristics

1000Vac

250Vac

Catalog Symbol and Current Ratings

TDC11-50mA

TDC11-1.5A

Current
Rating

GBB-1

GBB-6

GBB-15

TDC11-60mA

TDC11-2A

GBB-1⁄Ω¢

GBB-7

GBB-20

TDC11-100mA

TDC11-3A

GBB-2

GBB-8

GBB-25

TDC11-150mA

TDC11-5A

GBB-3

GBB-9

GBB-30

TDC11-250mA

150Vac

GBB-4

GBB-10

—

750Vac

TDC11-7A

GBB-5

GBB-12

—

TDC11-500mA

100Vac

500Vac

TDC11-10A

TDC11-750mA

—

350Vac

—

TDC11-1A

—

Data Sheet: 2013

Rated
Voltage
ac (Max.)

Interrupting
Rating1
ac

⁄Ω¡ §
250V
35A
⁄Ω¡ º
250V
35A
⁄Ω•
250V
35A
¤Ω¡ º
250V
35A
‹Ω¡ §
250V
35A
⁄Ω¢
250V
35A
‹Ω¡ º
250V
35A
‹Ω•
250V
35A
⁄Ω™
250V
35A
‹Ω¢
250V
35A
1
250V
35A
1⁄Ω¢
250V
100A
1⁄Ω™
250V
100A
2
250V
100A
2⁄Ω¢
250V
100A
2⁄Ω™
250V
100A
3
250V
100A
4
250V
200A
5
250V
200A
6
250V
200A
7
250V
200A
8
250V
200A
9
32V
1000A
10
32V
1000A
12
32V
1000A
15
32V
1000A
20
32V
1000A
25
32V
1000A
30
32V
1000A
1Interrupting ratings were measured at 70% – 80% power
factor on ac, and at a time constant described in UL 198L.

Data Sheet: 2043

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet:2004

35

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ and ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses

MDQ
MDQ-V (Axial Leads)

MDA
MDA-V (Axial Leads)

Dual Element Time-Delay
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG)
(6.3mm ≈ 32mm)
Construction: Glass Tube; Nickel
Plated Brass End Caps
Agency Information: Std. 248-14
UL Listed, File E19180; Guide JDYX,
⁄Ω¡§-7A
CSA Certification, File 47233,
Class 1422-01, ⁄Ω¡§-7A
UL Recognized, Guide JDYX2,
File E19180, 7.1-30A

Time-Delay
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AB)
(6.3mm ≈ 32mm)
Construction: Ceramic Tube; Nickel
Plated Brass End Caps
Agency Information: Std. 248-14
UL Listed, Guide JDYX, File E19180,
0-15A
CSA Certification, Class 1422-01,
File 53787, 0-15A

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

MDQ-‹Ω•

MDQ-1°Ω¡º

MDQ-⁄Ω£™

MDQ-›Ω¡º

MDQ-2

MDQ-⁄Ω¡§

MDQ-⁄Ω™

MDQ-2⁄Ω¢

MDQ-⁄Ω¡º

MDQ-flꭧ

MDQ-2⁄Ω™

MDQ-⁄Ω•

MDQ-‹Ω¢

MDQ-2°Ω¡º

MDQ-⁄fiΩ¡ºº

MDQ-°Ω¡º

MDQ-3

MDQ-⁄‡fiΩ¡ººº

MDQ-1

MDQ-3¤Ω¡º

MDQ-‹Ω¡§

MDQ-1¤Ω¡º

MDQ-4

MDQ-¤Ω¡º

MDQ-1⁄Ω¢

MDQ-5

MDQ-⁄Ω¢

MDQ-1⁄Ω™

MDQ-6

MDQ-‹Ω¡º

MDQ-1flꭧ

MDQ-6⁄Ω¢

MDQ-7⁄Ω™

MDQ-9

MDQ-12

MDQ-8

MDQ-10

MDQ-15

MDQ-7

32Vac

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings
250Vac

32Vac

AGU-1

AGU-4

AGU-20

AGU-50

AGU-2

AGU-5

AGU-25

AGU-60

AGU-3

AGU-8

AGU-30

—

—

AGU-10

AGU-35

—

—

AGU-15

AGU-40

—

Current
Rating

Rated
Voltage
ac (Max.) dc (Max.)

Interrupting
Rating1
ac
dc

¤Ω¡ º
⁄Ω¢
⁄Ω™

250V
250V
250V

35A
35A
35A

‹Ω¢
1
1⁄Ω™

250V
250V
250V

35A
35A
100A

2
2⁄Ω™
3

250V
250V
250V

100A
100A
100A

4
5
6

250V
250V
250V

200A
200A
200A

7
8
10

250V
250V
250V

200A
200A
200A

MDA-12

Voltage: 250Vac (⁄Ω¡ººA-7A)
32Vac (7⁄Ω™A-7A)
Interrupting Rating:
35A @ 250Vac (⁄Ω¡§A-1A)
100A @ 250Vac (1⁄Ω¢A-3A)
200A @ 25Vac (4A-7A)
1kA @ 32Vac (7⁄Ω™A-12A)
Data Sheet: 2044

36

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5 AG)
(10.3mm ≈ 38.1mm)
Construction: Glass Tube
No Agency Listings

Electrical Characteristics

250Vac
MDQ-⁄Ω¡ºº

AGU

15
20
25

250V
250V
250V

125V
125V

1500A
1500A
1000A

10kA
10kA

30

250V

125V

1000A

10kA

1Interrupting

ratings were measured at 70% – 80% power
factor on ac, and at a time constant described in UL 248.

Data Sheet: 2002

Data Sheet: 2008

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

Pin Indication Type

GBA and GLD

MIC and MIN

FNA

Fast Acting
Physical Size:
⁄Ω¢∑ ≈ 1⁄Ω¢∑ (3AG)
(6.6mm ≈ 31.8mm)
Agency Information: Std. 248-14
UL Listed, 0-5A/125Vac,
10,000 AIC, Guide JDYX,
File E19180
UL Recognized,
6A/125Vac, 1000AIC
8-15A/50Vac/dc, 300 AIC
Guide JDYX2, File E19180
CSA Certified:
0-5A/125Vac, 10,000 AIC
Class 1422-01, File 53787
General Information: Type GBA
has a “red” pin for high visibility. Type
GLD has an Albaloy-plated pin for
positive, electrical signal circuit
activation.

Fast Acting
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (5AG)
(10.3mm ≈ 38.1mm)
Agency Information: Std. 248-14
MIC—0-15A UL Listed, Guide JDYX,
File E19180
MIN—1-5A CSA Certified,
Class 1422-01, File 53787
General Information: Type MIN
has a “red” pin for high visibility. Type
MIC has a silver-plated pin for positive,
electrical signal activation.

Time-Delay
Physical Size:
⁄‹Ω£™∑ ≈ 1⁄Ω™∑
(10.3mm ≈ 38.1mm)
Agency Information: Std. 248-14
UL Listed ⁄Ω¡º-°Ω¡ºA, IR 35A@ 250V

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings
GLD-⁄Ω™

GLD-2

GLD-6

GLD-‹Ω¢

GLD-3

GLD-10

GLD-1

GLD-4

GLD-12

GLD-1⁄Ω™

GLD-5

GLD-15

GBA-⁄Ω™

GBA-2

GBA-8

GBA-‹Ω¢

GBA-3

GBA-10

GBA-1

GBA-4

GBA-15

GBA-1⁄Ω™

GBA-5

IR 10kA@ 125V
1-15A, IR 10kA@ 125V

Guide JDYX, File 19180
CSA Certified, 0-°Ω¡º A/250V,
1-10A/125V, Class 1422-01,
File 53787
General Information: Fuses above
10A have dual-tube construction.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Catalog Symbol & Current Ratings
250Vac

32V

MIC-1
(IR = 35A)

MIC-5
(IR = 200A)

MIC-20
(IR = 10kA)

MIC-2
(IR = 100A)

MIC-10
(IR = 200A)

MIC-25
(IR = 10kA)

MIC-3
(IR = 100A)

MIC-15
(IR = 750A)

MIC-30
(IR = 10kA)

MIC - (1-15)UL Listed 125Vac / IR = 10kA
250Vac

Catalog Symbol & Current Ratings
250Vac IR*

125Vac IR

125Vac IR

125Vac

FNA-⁄Ω¡ º

FNA-1

FNA-3

FNA-9

FNA-⁄Ω•

FNA-1⁄Ω•

FNA-3¤Ω¡ º

FNA-10

FNA-⁄fiΩ¡ ºº

FNA-1⁄Ω¢

FNA-3⁄Ω™

FNA-12 10,000A

32V

FNA-¤Ω¡ º

MIN-1
(IR = 35A)

MIN-5
(IR = 200A)

MIN-20
(IR = 10kA)

FNA-⁄Ω¢

MIN-2
(IR = 100A)

MIN-10
(IR = 200A)

MIN-25N
(IR = 10kA)

FNA-›Ω¡ º

FNA-1°Ω¡ º

FNA-5flΩ¡ º

FNA-25

FNA-⁄Ω™

FNA-2

FNA-6

FNA-30

MIN-3
(IR = 100A)

MIN-15
(IR = 750A)

MIN-30
(IR = 10kA)

FNA-flΩ¡ º

FNA-2⁄Ω¢

FNA-6⁄Ω¢

—

FNA-‹Ω¢

FNA-2⁄Ω™

FNA-7

—

FNA-°Ω¡ º

FNA-2°Ω¡ º

FNA-8

—

FNA-‹Ω¡ º

FNA-1›Ω¡ º
IR
35A

FNA-1⁄Ω™

FNA-4
IR

FNA-15

FNA-4⁄Ω™

FNA-1flΩ¡ º 10,000A FNA-5

IR

IR
10,000A

32 Volts†
FNA-20
IR%
1kA@
32V

*Interrupting rating of 10,000A at 125V.
†Interrupting rating of 1,000A at 32V.

Data Sheet: 2012

Data Sheet: 2047

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 2029

37

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

Pin Indication Type/Actuators/Limiters

ANN Limiter

MIS

KAZ

Non-Time-Delay
Physical Size:
⁄‹Ω£™∑ ≈ 2∑
(10.3mm ≈ 50.8mm)
Voltage Rating: 600Vac
Interrupting Rating: 200,000 AIC

Actuator (Not a Fuse)
Physical Size:
⁄‹Ω£™∑ ≈ 2∑
(10.3mm ≈ 50.8mm)
Voltage Rating: 600Vac
Interrupting Rating: 200,000A
Agency Information:
UL Listed, Guide JDVS,
File E58836
Recommended Use: Mounts in
Buss signal blocks 2778, 2837 and
2838.
General Information: Connects in
parallel with fuses having a rating of
50 amperes or larger and opens at
10A or more.

Catalog Symbol & Current Ratings
600Vac
MIS-1

MIS-4

MIS-10

MIS-2

MIS-5

MIS-12

MIS-3

MIS-8

Test Specifications
Fuse

Load

Opening Time

All

110%

4 hrs. (min.)

1-5A

150%

6 min. (max.)

6-12A

150%

12 min. (max.)

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Very Fast Acting
Physical Size:
‡Ω•∑ ≈ 3‹Ω¡§∑
(22.2mm ≈ 81.0mm)
Voltage Rating: 125Vac IR = 2500A
80Vdc IR = 2700 A
Agency Information: 35-400A @
125Vac, IR=2500A and 80Vdc,
IR=2700A: UL Recognized Guide
JFHR2, File E56412; CSA Certified Class
1422-30, File 53787
CE for 35-400A
Fuseholder: 4164
Catalog Symbol & Current Ratings
ANN-10

ANN-90

ANN-225

ANN-400

ANN-35

ANN-100

ANN-250

ANN-500

ANN-40

ANN-125

ANN-275

ANN-600

ANN-50

ANN-150

ANN-300

ANN-700

ANN-60

ANN-175

ANN-325

ANN-800

ANN-80

ANN-200

ANN-350

Data Sheet: 2023 & 2133

ANL
Non-Time Delay
Voltage Rating: 80Vdc
Agency Information:
UL Recognized, CSA Certified,
35-750A @ 80Vdc, IR = 2700A
Guide JFHR2, File E56412
Class 1422-30, File 53787
Fuseholder: 4164
Catalog Symbol & Current Ratings
ANL-35
ANL-40
ANL-50
ANL-60
ANL-80
ANL-100

Data Sheet: 2021

38

ANL-125
ANL-130
ANL-150
ANL-175
ANL-200
ANL-225

ANL-250
ANL-275
ANL-300
ANL-325
ANL-350
ANL-400

Data Sheet: 2024 & 2133

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

ANL-500
ANL-600
ANL-675
ANL-750
—
—

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

In-Line Fuse and Fuseholders
GLR

*HLR

Fast Acting, Non-rejecting
Voltage Rating: 300Vac or less
Interrupting Rating: 10,000A
Agency Information: Std. 248-14
UL Listed, 0-15A/300Vac
(Guide JDYX, File E19180)
CSA Certified, 0-10A/300V
(Class 1422-01, File 53787)

GMF and GRF

Fuseholder Time Delay, Non-rejecting
Voltage Rating: 300Vac or less
Interrupting Rating: 10,000A
Agency Information: Std. 248-14
0-10A, UL Listed (Guide JDYX,
File E19180)
CSA Certified, (Class 1422-01,
File 53787)
Electrical Ratings for Type GMF and
GRF Fuses and Non-Rejection Style Carriers

Electrical Ratings for Type GLR Fuses
and Non-Rejection Style Carriers
Fuse

Carrier1, 2

Fuse

Carrier1, 2

Fuse

Carrier1, 2

Fuse

Carrier1, 2

GLR-‹Ω¡ §
GLR-⁄Ω™
GLR-1
GLR-1 ⁄Ω™
GLR-1 flΩ¡ º
GLR-2
GLR-3
GLR-4

HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR

GLR-5
GLR-6
GLR-7
GLR-8
GLR-9
GLR-10
GLR-12
GLR-15

HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR-2A

GMF-‹Ω¡ º
GMF-⁄Ω™
GMF-flΩ¡ º
GMF-°Ω¡ º
GMF-1
GMF-1⁄Ω¢
GMF-1flΩ¡ º
GMF-2
GMF-2 ⁄Ω™
GMF-2 °Ω¡ º

HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR

GMF-3
GMF-3 ¤Ω¡ º
GMF-4
GMF-5*
GMF-6 ⁄Ω¢
GMF-10
GRF-7
GRF-8
GRF-10

HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR

1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified,
Class 6225-01, File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness
0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”
*For two leads order HLR-2A, 15A, 300V
• An alternative to the HLR fuseholder is the A fuseholder. The A fuseholder comes
WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side
receptacle as well as into the load side receptacle. It has the same body dimensions,
utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A
fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA
Certified, 10A, 300Vac, Class 6225-01, File 47235.
• Do not put tension on line (rear) terminal of fuseholder.

1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified,
Class 6225-01, File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness
0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”
*For two leads order HLR-2A, 15A, 300V
• An alternative to the HLR fuseholder is the A fuseholder. The A fuseholder comes
WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side
receptacle as well as into the load side receptacle. It has the same body dimensions,
utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A
fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA
Certified, 10A, 300Vac, Class 6225-01, File 47235.
• Do not put tension on line (rear) terminal of fuseholder.

CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann
Application Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann
Application Engineering at 636-527-1270 for more information.

Data Sheet: 2032

Data Sheet: 2031

GLQ

HLQ3

Fast-Acting, Size Rejecting
Voltage Rating: 300Vac or less
Interrupting Rating: 10,000A
Agency Information: Std. 248-14
UL Listed (Guide JDYX,
File E19180)
CSA Certified, (Class 1422-01,
File 53787)

Fuseholder Time-Delay, Size Rejecting
Voltage Rating: 300Vac or less
Interrupting Rating: 10,000A
Agency Information: Std. 248-14
UL Listed (Guide JDYX, File E19180)
CSA Certified, (Class 1422-01,
File 53787)

GMQ

Electrical Ratings for Type GMQ Fuses
and Rejection Style Carriers

Electrical Ratings for Type GLQ
Fuses and Rejection Style Carriers
Fuse

Carrier3, 4

Fuse

Carrier3, 4

Fuse

Carrier3, 4

Fuse

Carrier3, 4

GLQ-1
GLQ-1⁄Ω™
GLQ-1flΩ¡ º
GLQ-2
GLQ-2 ⁄Ω™

HLQ-1flΩ¡ º
HLQ-1flΩ¡ º
HLQ-1flΩ¡ º
HLQ-3 ¤Ω¡ º
HLQ-3 ¤Ω¡ º

GLQ-3
GLQ-4
GLQ-5
GLQ-9
GLQ-10

HLQ-3 ¤Ω¡ º
HLQ-5
HLQ-5
HLQ-10
HLQ-10

GMQ-⁄Ω™
GMQ-flΩ¡ º
GMQ-°Ω¡ º
GMQ-1
GMQ-1⁄Ω¢
GMQ-1flΩ¡ º
GMQ-2

HLQ-⁄Ω™
HLQ-1flΩ¡ º
HLQ-1flΩ¡ º
HLQ-1flΩ¡ º
HLQ-1flΩ¡ º
HLQ-1flΩ¡ º
HLQ-3 ¤Ω¡ º

GMQ-2⁄Ω™
GMQ-3
GMQ-3 ¤Ω¡ º
GMQ-4
GMQ-6
GMQ-6 ⁄Ω¢

HLQ-3 ¤Ω¡ º
HLQ-3 ¤Ω¡ º
HLQ-3 ¤Ω¡ º
HLQ-5
HLQ-8

3) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified,
Class 6225-01, File 47235 10A, 300Vac.
4) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness
0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”
• Do not put tension on line (rear) terminal of fuseholder.

CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann
Application Engineering at 636-527-1270 for more information.

3) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified,
Class 6225-01, File 47235 10A, 300Vac.
4) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness
0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”
• Do not put tension on line (rear) terminal of fuseholder.

CE logo denotes compliance with European Union Low Voltage Directive (501000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann
Application Engineering at 636-527-1270 for more information.

Data Sheet: 2033
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 2030

39

®

Bussmann

Electronic - PC Board and Small Dimension Fuses

Blade-Type Fuses

ATC® Blade-Type Fuse

ATM Mini–Fuse®

MAX Maxi–Fuse®

Fast Acting
Voltage Rating: 32Vdc
Interrupting Rating: 1,000A
Agency Information:
UL Recognized, (3-40A)
(Guide JFHR2, File E56412)

Fast Acting
Voltage Rating: 32Vdc
Interrupting Rating: 1,000A

Fast Acting
Voltage Rating: 32Vdc
Interrupting Rating: 1,000A

Catalog Symbol & Current Ratings

Catalog Symbol & Current Ratings

Catalog Symbol & Current Ratings

ATC-1

Black

ATM-2

Gray

MAX-20

Yellow

ATC-2

Gray

ATM-3

Violet

MAX-30

Green

ATC-3

Violet

ATM-4

Pink

MAX-40

Orange

ATC-4

Pink

ATM-5

Tan

MAX-50

Red

ATC-5

Tan

ATM-7⁄Ω™

Brown

MAX-60

Blue

ATC-7⁄Ω™

Brown

ATM-10

Red

MAX-70

Tan

ATC-10

Red

ATM-15

Blue

MAX-80

Clear

ATC-15

Blue

ATM-20

Yellow

ATC-20

Yellow

ATM-25

Clear

ATC-25

Clear

ATM-30

Green

ATC-30

Green

ATC-40

Orange

Refer to page 82 for In-Line Fuseholders for Blade
Type Fuses.

Refer to page 82 for In-Line Fuseholders for Blade
Type Fuses.

Refer to page 82 for In-Line Fuseholders for Blade
Type Fuses.

Data Sheet: 2009

40

Data Sheet: 2048

Data Sheet: 2049

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Optima® Three Pole Overcurrent Protection Module
Fuseholder Wire Range:
75°CU Only
#18-12 Single/Dual, torque 15 lb: in.
#10-8 Single/Dual, torque 20 lb: in.
Dual wire. Wire with same guage and type
75°CU Only

Solid

Class CC Version
Catalog Symbol: OPM-NG-SC3
Electrical Rating: 30A, 600Vac (or less)
Withstand Rating: 200kA
Use with Class CC fuse type: LP-CC, FNQ-R, KTK-R

Stranded

Agency Information:
UL
OPM-NG-SC3
UL Listed, UL 512, File E14853, Guide IZLT
OPM-NG-SM3
UL Recognized, UL512, File E14853, Guide IZLT2
CSA Certified, C22.2 No. 39, Class C6225-01, File 47235
IEC 60947-3 Utilization Category AC20B
Packaging Weight: 0.39lb. (0.18 kg)
Handling & Storage Specifications:
Storage Temperature: -10°C to 65°C
Attributes:
• 45mm width matches IEC starters.
• Phil-slot screws.
• Pressure plate terminations.
• Integrated collapsible handle.
• Fuse carrier cannot be removed from holder base.
• IP20 finger safe to IEC60529
• Auxilliary contacts. - optional accessory
• Dual-wire rated terminals (see Wire Table).
• 35mm DIN rail or panel mounting feature. Maximum
screw size #8 (M4).
• Padlockable
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

[mm2 ]

18-8 x1
18-8 x2
18-8 x1
18-8 x2

1..6 x1
1..6 x2
1.5..6 x1
1.5..6 x2
1..4 x1
1..4 x2

Ferrules

(Nm)/lb in
18-12Single/Dual
15 lb in 1 . 7

(N m )

10-8 Single/Dual
20 lb in 2 . 5

(N m)

Input Power Terminal Wire Range:
Wiring

13/32” x 1-1/2” and 10,3 x 38mm Version
Catalog Symbol: OPM-NG-SM3
Electrical Rating: UL and CSA 30A, 600Vac (or less)
IEC 32A, 690Vac (or less)
Withstand Rating: Limited by fuse IR, 200kA maximum
Use with 13/32” x 1-1/2” fuse types: KTK, FNQ, KLM
Use with 10 x 38mm fuse types: FWA, FWC,
C10G_ _, C10M_ _

AWG

(1) #14 to #2 (1.5 to 25mm2 )
conductor or
(2) #14 to #6 (1.5 to 10mm2 )
conductors
(1) #14 to #2 (1.5 to 25mm2 )
conductor or
(2) #12 to #6 (2.5 to 10mm2 )
conductors
20 lb..in. (2.2 N.m)
15 lb..in. (1.7 N.m)

Solid
Conductor
Stranded
Conductor

Tightening
Torque:

Connector
Screw
Clamp

Materials:
Housing: Thermoplastic- UL V-2
Clip: Tin plated copper alloy
Contact Lubricant: Fluoroether grease
Saddle screw: Plated steel
DIN rail springs: Stainless steel

Optional Accessories:
Comb Bar (Max. current rating = 63A)
OPMNGSA245
OPMNGSA254
OPMNGSA272
OPMNGSA345
OPMNGSA354
OPMNGSA445
OPMNGSA454
OPMNGSA472
OPMNGSA554

2
2
2
3
3
4
4
4
5

circuit,
circuit,
circuit,
circuit,
circuit,
circuit,
circuit,
circuit,
circuit,

45mm
54mm
72mm
45mm
54mm
45mm
54mm
72mm
54mm

between
between
between
between
between
between
between
between
between

same
same
same
same
same
same
same
same
same

phases
phases
phases
phases
phases
phases
phases
phases
phases

Input Terminal Block
OPMNGSA005

OPMNGSA009

Input/Feed Through Power Terminal,
Supports feed through
to another system, DIN-rail mount only
Input Power Terminal

Cover
OPMNGSA010

Protective Cover for unused terminals on
comb bar

Auxilliary Contacts
OPMNGSAAUX11
OPMNGSAAUX20

NO/NC
NO/NO

Marking Tabs
OPMNGSA101

Marking Tab - Mounts to front of carrier,
quantity 100
Data Sheet: 1109

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

41

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Optima® Three Pole Overcurrent Protection Module
Optional Accessories

Dimensional Data

Millimeters (± 0.38)
Inches (± .015)

Data Sheet: 1109

42

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Optima® Overcurrent Protection Module - Fuseholder
Product Features
• “Open” fuse indication lights.
• Cam action handle for easy removal.
• Finger safe terminals. (Qualified as IP20 per IEC 529)
• Removable module for convenient fuse loading.
• 35mm DIN-rail or screw panel mounting (#8 screw,
1⁄Ω¢” long).
• Dead-front construction.
• Padlockable.
Additional Features
• Option for remote “open fuse” status indication feature
available (less downtime!). See BIF document for additional
wiring details.
• Offered with Class CC rejection clips or European
10 ≈ 38mm clips to meet global needs.
• Wire ready: Saves time as terminals are ready to
accept wires.

Catalog Symbol:
Series

O P M -

1

0 3

Fuse Type

Communication

Blank - 10 x 38mm
or 13/32” x 1-1/2”
R - Class CC

C - Communication
Feature

8

Dimensional Data

Midget (Non-Rejection)

European

LP-CC

KTK

C10M

KTK-R

FNM

C10G

FNQ-R

FNQ

Physical Characteristics
• Small size matches 45mm IEC starter width.
• Accepts #8-18 AWG stranded, #10-18 AWG solid wire.
• 3-pole.

OPM-1038

30A, 600V UL/CSA**
(Max. 3 Watts per fuse)
32A, 660V IEC

OPM-1038R

30A, 600V UL/CSA**

OPM-1038C

30A, 600V UL/CSA**
(Max. 3 Watts per fuse)
32A, 660V IEC

OPM-1038RC

30A, 600V UL/CSA**

SC
Rating
*

200kA
*

200kA

Clips
Non-rejection,
10 x38mm or
13/32” x 1-1/2”
Rejection,
Class CC
Non-rejection,
10 x38mm or
13/32” x 1-1/2”
Rejection,
Class CC

BUSS

Recommended Fuse Types

Non-Switch Series
Catalog
Number
Electrical Rating

Communication
Port

IL1
4T2
1.76 ∑ (± .03)
(44.7mm) (± .7 )
6T3

Non-Switch Series
for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10mm x 38mm) Fuses
Materials: Grey Thermoplastic
UL Flammability: UL 94V0
Agency Information:
UL (see table)
CSA Certified, C22.2 No. 39, Class 6225-01, File 47235
IEC (see table)
Shipping Weight: Approximately 213g/.47 lb.
Carton Quantity: 1
Class CC

3.22∑ (± .03)
(81.8mm) (± .76)
2T1

3L2

.27∑ (6.9mm)

5L3

.74∑ (18.8mm)
.31∑ (7.9mm)

3.60∑ (± .03)
(91.4mm) (± .76)

.57∑
(14.5mm)

3.74∑ (± .03)
(95.0mm)
(± .76)

3.17∑
(80.5mm)
Communication
Port

1.65∑ (± .03)
(41.9mm) (±. 76)

0.23∑
(5.8mm)

.50∑ (12.7mm)
.44∑ (11.2mm)

.224"
(5.6mm)

1.312∑
(± .01)
(33.3mm)
(± .25)
Panel Mount
Hole Pattern

3.60∑ (± .03)
(91.4mm) (± .76)
1.86∑ (± .03)
(47.2mm)
(± .76)
Panel Mount
Hole Pattern

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Remote Open
Fuse Indication

Std.

UL Information
File
Guide

No

Recognized
UL 512

E14853

IZLT2

No

Listed
UL 512

E14853

IZLT

Yes

Recognized
UL 512

E14853

IZLT2

Yes

Listed
UL 512

E14853

IZLT

IEC

CE

IEC 269-2-1 Yes
Yes

IEC 269-2-1 No
No

*Rating varies depending on fuse used in module; 200kA maximum
**DC voltage rating: 600V UL/CSA

Data Sheet: 1102
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

43

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Optima® Overcurrent Protection Module - Fuseholder
and Disconnect Switch
Physical Characteristics
• Small size matches 45mm IEC starter width.
• Accepts #8-18 AWG stranded, #10-18 AWG solid wire.
• 3 pole.
• Handle and shaft required for through the door operation.
See BIF document for details.

Catalog Symbol:
Series

Fuse Type

Communication

O P M - 1 0 3 8

S W
Blank - 10 x 38mm
or 13/32” x 1-1/2”
R - Class CC

C - Communication
Feature

5.72∑ (± .045)
(145.3mm) (± 1.14)

Dimensional Data

4.25∑ (± .03)
(108.0mm) (± .76)
0.43∑ (± .03)
(10.9mm) (± .76)
1.38∑
(35.0mm)

2T1
4T 2
6T3

1L1
BUSS

Load Break Disconnect Switch
for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10mm x 38mm) Fuses
Materials: Grey Thermoplastic
UL Flammability: UL 94V0
Agency Information:
UL (see table)
CSA Certified, C22.2 No. 39, Class 6225-01, File 47235
IEC (see table)
Shipping Weight: Approximately 335g/.74 lb.
Carton Quantity: 1

Product Features
• “Open” Fuse indication lights.
• Finger safe terminals.(Qualified as IP20 per IEC 529)
• Cam action handle for easy module removal.
• 35mm DIN-rail or screw panel mounting (#8 screw,
1⁄Ω¢” long).
• Dead front construction. No exposed contacts for added
safety.
• Padlockable.
• Option for remote “open fuse” status indication feature
available (reduces downtime!). See BIF document for
additional wiring details.
• Offered with Class CC rejection clips or European
10 ≈ 38mm clips to meet global needs.
• Wire ready: Saves time as terminals are ready to
accept wires.

Communication
Port

1.76∑
.27∑ (6.9mm) (44.7mm)

3L2
5L3

.74∑ (18.8mm)
.31∑ (7.9mm)

Horsepower Rating of Switch
3PH

V

0.57∑ (± .03)
(14.5mm) (± .76)

240

480

600

5

10

15

HP

3.74∑ (± .03)
(95.0mm) (± .76)

Recommended Fuse Types
Class CC

Midget (Non-Rejection)

European

LP-CC

KTK

C10M

KTK-R

FNM

C10G

FNQ-R

FNQ

Switch Series
Catalog
Number
OPM-1038SW

Electrical Rating
30A, 600Vac UL/CSA

OPM-1038RSW

32A, 660Vac IEC
30A, 600Vac UL/CSA

OPM-1038SWC

30A, 600Vac UL/CSA

32A, 660Vac IEC
OPM-1038RSWC 30A, 600Vac UL/CSA

0.23∑
(5.8mm)

.50∑ (12.7mm)
.44∑ (11.2mm)

.224∑
(5.6mm)

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Communication
Port

3.17∑
(80.5mm)

1.86∑
(47.2mm)
Panel Mounting
Hole Pattern
3.60∑
(91.4mm)

1.312∑
(± .01)
(33.3mm)
(± .25)
Panel Mounting
Hole Pattern

SC
Remote Open
Rating
Clips
Fuse Indication
*
Non-rejection,
No
10x38mm or
13/32” x 1-1/2”
100kA Rejection,
No
Class CC
*
Non-rejection,
Yes
10x38mm or
13/32” x 1-1/2”
100kA Rejection,
Yes
Class CC

UL Information
Std.
File
Guide
Recognized
UL 508
Listed
UL 508
Recognized
UL 508
Listed
UL 508

E161278

NLRV2

E161278

NLRV

E161278

NLRV2

E161278

NLRV

IEC

IEC 947-3

Yes
Yes

IEC 947-3

*Rating varies depending on fuse used in module; 100kA maximum

Data Sheet: 1103

44

CE

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

No
No

Blank Page 45
Do Not Print

Fuseblocks, Holders and Terminal Blocks

Bussmann®

SAMI Fuse Covers
Dimensional Data (inches)
Catalog
Number**

Description

A

B

C

SAMI-1_

600V, J (0-30A) and 600V, T (35-60A)*
250V, RK, K5, H (35-60A)

5.02

1.03

1.94

SAMI-2_

600V, RK, K5, H (0-30A)

7.03

1.30

2.07

SAMI-3_

600V, J (65-100A)

7.03

1.30

2.33

SAMI-4_

250V, RK, K5, H (65-100A)

8.20

1.30

2.18

SAMI-5_

600V, RK, K5, H (35-60A)

8.20

1.30

2.18

SAMI-6_

600V, J (35-60A)

4.98

1.17

2.14

SAMI-7_

600V, Midget, Class CC, G (0-30A)

SAMI-8†_ 600V, RK, K5, H (65-100A)
SAMI-9_

3.82

0.75

1.72

10.38

1.50

2.33

3.82

0.75

1.72

250V, RK, K5, H (0-30A) and 600V,
T (0-30A)

*Available in non-indicating only.
†SAMI-8A adapter available for small fusetron body design. SAMI-8I and SAMI-8N come
standard with adapter (SAMI-8A).

**Catalog Numbers
For Indicating Cover, add suffix I.
For Non-indicating cover, add suffix N.
Example: SAMI-7I = Indicating
SAMI-7N = Non-indicating

SAMI Series

WARNING: To avoid electrical shock, turn power off before
installing, removing or servicing.
Dimensional Data

TEST PROBE

LINE

TEST PROBE

Buss

SAMI -2

• Innovative design, covers exposed terminals and contacts
of Bussmann fuseblocks.
• Fits most competitive fuseblocks.
• Buss Yellow light on indicating SAMI shows when the fuse
is open—helps trouble shoot the system and reduces
downtime.
• All versions are reusable—no need to pay for indication
every time a fuse opens.
• Indication contacts have teeth to break oxidation layer on
the existing fuse endcap to provide a clear signal path.
• Less than .6mA leakage current at 600 volt.
• Visual marking of line and load side.
• SAMI cover ends can easily be cut away if necessary, to fit
cover over existing wiring or to fit most safety switches.
• Dead front construction provides added protection against
accidental contact by maintenance personnel.
• Labels are provided with the SAMI fuse cover for writing in
circuit or fuse information.
• One cover is required for each pole.

Indicating feature requires a minimum of 90Vac or 115Vdc to illuminate lamp.

LOAD

For Class J, RK1, RK5, H, K5, CC, G (0-30A) and
Midget type fuses.
Voltage Rating:
Non-Indicating - 0-600Vac/dc
Indicating - 90 to 600Vac
-115 to 600Vdc
Ampere Rating: 0-100A
Agency Information: UL Listed; SAMI-1I through SAMI-6I
SAMI-8I and SAMI-9I, SAMI-1N through SAMI-6N, SAMI-8N
and SAMI-9N
UL Recognized; SAMI-7I and SAMI-7N
CSA Certified, File LR47235-93C

B

A

FUSE

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1204 (Trimming Guides: 12041, 12042, 12043,

12044, 12045, 12046, 12048, 12049)

46

C

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class H(K) and R Fuseblocks – 250V

H250 Series

For use with Class H Fuses
(Bussmann NON and REN).

R250 Series

For use with Class R Fuses
(Bussmann LPN-RK and FRN-R, DLN-R and KTN-R).
Construction: Thermoplastic, UL Flammability: 94VO
Ampere Ratings: ⁄Ω¡º-600A.
Withstand Ratings: H250 Series - 10,000A RMS Sym.;
R250 Series - 200,000A RMS Sym.
Voltage Rating: H250, 250V; R250, 250V
Agency Information: UL Listed UL512, Guide IZLT,
File E14853; CSA Certified, Class 6225-01, File 47235
Class H Fuseblocks (250V) Catalog Data (for NON and REN Fuses)

Copper Only

0.25∑ Quick Connect

—
—

Clip w/ Reinforced
Spring (Copper Only)

—
—

P
P
P

PR
PR
PR

C
C
C

CR COR
CR COR
CR COR

CO
CO
CO

Q
Q
Q

Fig.
No.
1
2
3

— —
— —

C
C

CR
CR

COR
COR

CO
CO

—
—

4
5

Clip with
Reinforced Spring

SR
SR
SR

Pressure Plate & Clip
with Reinforced Spring
—

H25060-1
H25060-2

S
S
S

Dimensions (Inches) – See Next Page For Figures

Pressure Plate

1
2

Clip with
Reinforced Spring

31
to

1
2
3

Basic
Catalog
Number
H25030-1
H25030-2
H25030-3

Poles

Amps
⁄Ω¡º
to
30

—

Terminal Type (Suffix No.)
Screw
Box Lug w/

A

B

C

D

E

F

G

H

1.25

—
1.31

J Dia.
x
C’ Bore

K

(See Figures)

4.25

1.73

1.5
2.81

1.5

0.5

0.5

60

3

H25060-3

—

—

— —

C

CR

COR

CO

—

6

61
to
100
101
to
200
201
to
400
401

1
2
3

H25100-1
H25100-2
H25100-3

— SR
— SR
— SR

— —
— —
— —

— CR
— CR
— CR

COR
COR
COR

—
—
—

—
—
—

7
8
9

4.125

1
3

H25200-1

—

—

—

—

— CR

—

—

—

10

H25200-3

—

—

—

—

— CR

—

—

—

11

1

H25400-1

—

—

—

—

— CR*

—

—

—

10

9.06

4.0

3.0

3.02

0.63

1.75

3.0

1.0

3

H25400-3

—

—

—

—

— CR† —

—

—

12

9.06

4.0

4.0

2.50

0.82

9.25

10.88

1.0

4.0

1.00

0.22 ≈ 0.41 0.27

3.09

3.0

C, CR #2-14 CU, #2-8 AL
CO, COR #2-14 CU ONLY

1.31
COR #1/0-8 CU ONLY
CR #1/0-8 CU/AL
SR #8W/ Ring Terminal

(See Figures)

7.125

Wire
Range
C, CR #2-14 CU, #2-12 AL
CO, COR #6-14 CU ONLY
P, PR #10-18 CU ONLY
Q N/A
S, SR #10-18 CU ONLY

2.06

0.5

2.0

3.0

0.75

—

0.31
CR 250kcmil-6 CU/AL

1
H25600-1 — —
— —
to
3
H25600-3
—
—
— —
600
*UL Recognized, CSA Certification.
†No UL, No CSA Certification.

— CR

(See Figures)

—

—

—

10

11.0

4.97

3.0

4.0

1.125

1.75

— CR† —

—

—

12

11.0

4.97

5.0

3.0

1.87

11.0

—

0.31

—

0.31

CR 500kcmil-4 CU/AL

CR (2) 500kcmil-4/0 CU/AL

14.74 1.00

Data Sheet:H250 Series,1112; R250 Series, 1110
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

47

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class H(K) and R Fuseblocks – 250V
Class R Fuseblocks (250V) Catalog Data (for LPN-RK, FRN-R, DLN-R and KTN-R Fuses)
Terminal Type (Suffix No.)

31
to
60
61
to
100
101
to
200
201
to
400

Box Lug w/
Clip
— Cu Only
CR
COR
CR
COR
CR
COR

Dimensions (Inches)

1
2
3

1
2
3
1
2
3

R25060-1
R25060-2
R25060-3
R25100-1
R25100-2
R25100-3

—
—
—
—
—
—

—
—
—
—
—
—

CR
CR
CR
CR
CR
CR

COR
COR
COR
COR
COR
COR

—
—
—
—
—
—

4
5
6
7
8
9

1
3

R25200-1
R25200-3

—
—

—
—

CR
CR

—
—

—
—

10
11

7.125

1

R25400-1

—

—

CR‡

COR‡

—

10

9.06

Poles

Amps
⁄Ω¡º
to
30

Screw w/
Pres.
—
Plate
SR
PR
SR
PR
SR
PR

Basic
Catalog
Number
R25030-1
R25030-2
R25030-3

3

R25400-3

—

—

401
1
R25600-1
—
—
to
3
R25600-3
—
—
600
*UL Recognized, No CSA Certification.
†No UL, No CSA Certification.
‡UL Recognized, CSA Certification

0.25⬙
QuickConnect
QR*
QR*
QR*

Fig.
No.
1
2
3

A

B

C

D

E

F

G

H

1.25

—
1.31
1.31

J Dia.
x
C’ Bore

K

0.22 x 0.41

0.27

(See Figures)

4.25

1.73

1.5
2.81
4.125

1.5

0.5

0.5

3.0

2.06

0.5

2.0

COR #2-14 CU ONLY
CR #2-14 CU, #2-8 AL
COR 1/0-8 CU ONLY
CR 1/0-8 CU/AL

(See Figures)

3.15

Wire
Range
COR #6-14 CU ONLY
CR #2-14 CU, #2-12 AL
PR #10-18 CU ONLY
QR N/A
SR #10-18 CU ONLY

3.0

0.75

3.0

1.0

—

0.31

—

0.56

—

0.56 CR (2) 500kcmil-4/0 CU/AL

CR 250kcmil-6 CU/AL

(See Figure)
4.0

3.0

3.02

0.91

1.75

CR†

COR†

—

12

9.06

4.0

4.0

2.5

0.82

9.25

10.88

1.0

CR
CR†

—
—

—
—

10
12

11.0
11.0

4.97
4.97

3.0
5.0

4.0
3.0

1.125
1.87

1.75
11.0

4.0
14.74

1.0
1.0

COR 500kcmil-4/0
CU ONLY
CR 500kcmil-4 CU/AL

CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer
to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information.

Dimensional Data
250V ⁄Ω¡ºA to 30A

1.41"
0.22"

1.09"
0.17"

0.75" 0.41"

2.05"
1.25"
0.95"

0.25"

3"
2.5"
2 SPACES AT
0.95" - 1.91"

1.27"

3.03"
0.5"
1.52"

0.22" DIAMETER
FIGURE 1.

0.55"
FIGURE 2.

0.55"
FIGURE 3.

Data Sheet: H250 Series,1112; R250 Series, 1110

48

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class H(K) and R Fuseblocks – 250V
250V, 31A to 60A
C

B
K

F

C

C
H

E

F

F

E

H

H

J

J

J

A

G

D

FIGURE 4.

FIGURE 5.

FIGURE 6.

250V, 61A to 100A
3.38"
1.56"

0.59"

1.81"

2.06"
0.25"

0.62"

0.59"

4.94"
1.56"
1.56"

0.62"

0.62"

0.28" DIA. x
0.5" C'BORE

7.36"
2.38"

3.125"

2.125"

FIGURE 7.

FIGURE 8.

250V, 101A to 200A

250V, 101A to 600A
B
H
K

FIGURE 9.
8"
5"

3.4"

G
F

E

6"

3"
.5"

1"

2"

7.13"

.34" DIA.
HOLE
THROUGH

0.34
DIAMETER
0.75"
C'BORE

4.5"

C A

EYELETS
TO ACCEPT
.25" DIA.
SCREW

3"

2.06"

D

9"

FIGURE 10.

FIGURE 11.

250V, 201A to 600A
G

B

F

E

H

A

C

.34" DIA.
HOLE
THRU

D

FIGURE 12.

Data Sheet: H250 Series,1112; R250 Series, 1110
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

49

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class H(K) and R Fuseblocks – 600V

H600 Series

For use with Class H Fuses
(Bussmann NOS and RES).
R600 Series For use with Class R Fuses
(Bussmann LPS-RK, FRS-R, DLS-R and KTS-R).
Construction: Thermoplastic, UL Flammability: 94VO
Ampere Ratings: ⁄Ω¡º-600A
Withstand Ratings: H600Series - 10,000A RMS Sym.;
R600 Series - 200,000A RMS Sym.
Voltage Rating: H600, 600V; R600, 600V
Agency Information: UL Listed UL512, Guide IZLT, File
E14853; CSA Certified, Class 6225-01, File 47235
Class H Fuseblocks (600V) Catalog Data (for NOS and RES Fuses)

31
to
60
61
to
100
101
to
200
201

Clip with
Reinforced Spring

Clip w/ Reinforced
Spring (Copper Only)

Copper Only

0.25∑ Quick Connect

1
3

Pressure Plate & Clip
with Reinforced Spring
—

H60060-1
H60060-2
H60060-3
H60100-1
H60100-2
H60100-3

Pressure Plate

1
2
3
1
2
3

Clip with
Reinforced Spring

1
2
3

Basic
Catalog
Number
H60030-1
H60030-2
H60030-3

Poles

Amps
⁄Ω¡º
to
30

Dimensions (Inches) – See Next Page For Figures

—

Terminal Type (Suffix No.)
Screw
Box Lug w/

S
S
S

SR
SR
SR

P
P
P

PR
PR
PR

CR COR
CR COR
CR COR

CO
CO
CO

—
—
—

C
C
C

Fig.
No.
1
2
3

— —
— —
— —
— SR‡
— SR‡
— SR‡

—
—
—
—
—
—

—
—
—
—
—
—

C
C
C
—
—
—

CR
CR
CR
CR
CR
CR

COR
COR
COR
COR
COR
COR

CO
CO
CO
—
—
—

—
—
—
—
—
—

4
5
6
1
2
3

H60200-1
H60200-3

—
—

—
—

—
—

—
—

— CR
— CR

—
—

—
—

—
—

1

H60400-1

—

—

—

—

— CR‡ COR‡

—

3

H60400-3

—

—

—

—

— CR† —
— CR
— CR†

A

B

6.25

1.73

C
1.54
2.90
4.25

D

E

F

G

H

J Dia.
≈
C’ Bore

K

1.56

.25

0.62

3.13

1.56

0.28 ≈ 0.5

.26

C, CR #2-14 CU, #2-8 AL
CO, COR #4-14 CU ONLY

(See Figures)

9.5

2.38

2.22
4.03
5.84

2.63

0.67

7
8

9.63

3.09

3.0

3.31

0.5

—

7

12.0

4.0

3.0

4.5

0.63

—

—

9

—
—

—
—

7
10

0.88

4.25

1.81

0.28 ≈ 0.50

.34

2.0
3.0
(See Figures)

0.75

—

0.31

1.0

—

0.56

1.0

—

1.75

3.0

to
400

401
1
H60600-1 — —
to
3
H60600-3 — —
600
†No UL, No CSA Certification.
‡UL Recognized, CSA Certification

— —
— —

—
—

(See Figures)
14.0

4.97

3.0

5.5

1.125 1.75
4.0
(See Figures)

Wire
Range
C, CR #2-14 CU, #2-12 AL
CO, COR #6-14 CU ONLY
P, PR, S, SR #10-18
CU ONLY

0.56

COR 1/0-8 CU ONLY
CR 1/0-8 CU/AL
SR #8w/ Ring Terminal
CR 250kcmil-6 CU/AL

COR 500kcmil-4/0
CU ONLY
CR 500kcmil-4 CU/AL

CR 500kcmil-4/0 CU/AL

CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: H600 Series, 1113; R600 Series, 1111

50

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class H(K) and R Fuseblocks – 600V
Class R Fuseblocks (600V) Catalog Data (for LPS-RK, FRS-R, DLS-R and KTS-R Fuses)
Terminal Type (Suffix No.)

1
2
3
1
2
3
1
2
3

Screw w/
Pres.
—
Plate
SR
PR
SR
PR
SR
PR
—
—
—
—
—
—
—
—
—
—
—
—

Box Lug w/
Clip
— Cu Only
CR
COR
CR
COR
CR
COR
CR
COR
CR
COR
CR
COR
CR
COR
CR
COR
CR
COR

1
3

R60200-1
R60200-3

—
—

—
—

CR
CR

—
—

CRQ†
—

1
3

R60400-1
R60400-3

—
—

—
—

CR‡
CR†

COR‡
—

—
—

CR
CR†

—
—

Poles

Amps
⁄Ω¡º
to
30
31
to
60
61
to
100
101
to
200
201
to
400

Dimensions (Inches)

Basic
Catalog
Number
R60030-1
R60030-2
R60030-3
R60060-1
R60060-2
R60060-3
R60100-1
R60100-2
R60100-3

401
1
R60600-1 —
to
3
R60600-3 —
600
†No UL, No CSA Certification.
‡UL Recognized, CSA Certification

0.25⬙
Quick- Fig.
Connect No.
—
1
—
2
—
3
—
4
—
5
—
6
—
1
—
2
CRQ†
3

A

B

6.25

1.73

C
1.54
2.90
4.25

D

E

F

G

H

J Dia.
x
C’ Bore

K

1.56

0.25

0.62

3.13

1.56

0.28 x 0.5

.26

COR #2-14 CU ONLY
CR #2-14 CU, #2-8 AL

(See Figures)

9.5

2.38

2.22
4.03
5.84

2.63

0.67

4.25

1.81

0.28 x 0.5

0.34

7
8

9.63

3.09

3.0

3.31

0.5
2.0
3.0
(See Figures)

0.75

—

0.31

—
—

7
9

12.0

4.0

3.0

4.5

0.63 1.75
3.0
(See Figures)

1.0

—

0.56

—
—

7
10

14.0

4.97

3.0

5.5

1.125 1.75
4.0
(See Figures)

1.0

—

0.56

0.88

Wire
Range
COR #6-14 CU ONLY
CR #2-14 CU, #2-12 AL
PR, SR #10-18 CU ONLY

COR 1/0 -8 CU ONLY
CR, CRQ 1/0-8 CU/AL
CR, CRQ
250kcmil-6 CU/AL
COR 500kcmil-4/0
CU ONLY
CR 500kcmil-4 CU/AL

CR (2) 500kcmil-4/0 CU/AL

CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer
to Data Sheet: 8002 or contact Bussmann Application Engineering at 314-527-1270 for more information.

Dimensional Data
600V, ⁄Ω¡º to 30A
and 61A to 100A
B
K

C

E

F

C

C
H

E

F

F

H

H

J

J

J

A

G

D

FIGURE 1.

FIGURE 2.

FIGURE 3.

Data Sheet: H600 Series, 1113; R600 Series, 1111
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

51

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class H(K) and R Fuseblocks – 600V
Dimensional Data
600V, 31A to 60A

1.81"

2.06"
0.25"

3.38"
1.56"

0.59"

0.62"

0.59"

4.94"
1.56"
1.56"

0.62"

0.62"

0.28" DIA. x
0.5" C'BORE

7.36"
2.38"

3.125"

2.125"

FIGURE 4

E

FIGURE 6

600V, 101A to 200A

600V, 101A to 600A
B
H
K

FIGURE 5

9.0"
8.0"
6.5"

G
F

0.34
DIAMETER

3.15"
.75"

0.34
DIAMETER

0.75"
C'BORE

C A

9.58"

0.75" DIA.
C'BORE
.50" Deep

5.5"
3.0"

D
2.04"

FIGURE 7

FIGURE 8

600V, 201A to 400A

600V, 401A to 600A

11.63"
9.25"

4.02"
1.00"

1.19"

2.13"

0.34
DIAMETER
0.75" DIA.
C'BORE
.67" Deep

12.00"
7.00"

15.26"
11.0"

4.987"
1.00"

0.34
DIAMETER
0.75" DIA.
C'BORE
.67" Deep

14.00"
8.00"

2.5"
2.5"

FIGURE 9
FIGURE 10

Data Sheet: H600 Series, 1113; R600 Series, 1111

52

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class J Fuseblocks
J600 Series

For use with Class J Fuses
(Bussmann® LPJ and JKS).
Catalog Symbol: J600 Series
Ampere Rating: ⁄Ω™-600A
Voltage Rating: 600V
Withstand Rating: 200,000 RMS Sym. Amps
Agency Information:
UL Listed, UL 512, Guide IZLT, File E14853
CSA Certified, C22.2 No. 39, Class 6225-01, File 47235
Materials: Thermoplastic
UL Flammability: UL 94V0

Standard J Fuseblocks (600V) Catalog Data
Amps

Poles

Screw†

Pressure
Plate†

1
2
3
1
2
3
1
3
1
3
1
3
1
3

J60030-1S(2)
J60030-2S(2)
J60030-3S(2)
—
—
—
—
—
—
—
—
—
—
—

J60030-1P
J60030-2P
J60030-3P
—
—
—
—
—
—
—
—
—
—
—

⁄Ω™-30

31-60

61-100
101-200
201-400
401-600

Catalog Numbers
Box
Box Lug w/
Lug
Retaining Clip
J60030-1C
J60030-2C
J60030-3C
J60060-1C
J60060-2C
J60060-3C
—
—
—
—
—
—
—
—

Fig.
No.

J60030-1CR††
1
J60030-2CR††
2
J60030-3CR††
3
J60060-1CR††
1
J60060-2CR††
2
J60060-3CR††
3
J60100-1CR
4
J60100-3CR††
5
J60200-1CR
6
J60200-3CR
7
J60400-1CR(3)
8
J60400-3CR(2)
9
J60600-1CR
10
J60600-3CR
11

Wire
Range
C, CR #2-14 CU, #2-8 AL
COR #2-14 CU ONLY
P, PR, S, SR #10-14 CU ONLY
C, CR, #2-14 CU/AL
COR #4-14 CU ONLY
COR 1/0-8 CU ONLY
CR, CRQ 1/0-8 CU/AL
CR 250kcmil-6 CU/AL
CR 500kcmil -4 CU/AL
CR (2) 500kcmil-4/0 CU/AL

†Clip reinforcing springs are standard on fuseblocks rated 100A and above. Available on 30A and 60A blocks by adding the letter “R” to the end of
the part number.
††Copper only connections available by changing “CR” suffix to “COR”.
(2)No UL, No CSA Certification
(3)UL Recognized, CSA Certification

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data

All dimensions (±0.015)

⁄Ω™-60A

61-100A

1.702

3.202

.750

2.250

4.702

2.415"

2.250

.750

C
L

5"

2.28"
.30"

4.005

.94"

1.583"

.22"
Dia.
.5"
C'Bore

6.28"

CL

3.14"

1.500

1.75"

FIGURE 1.

FIGURE 2.

FIGURE 3.

FIGURE 4.

1.5"

FIGURE 5.

Data Sheet: 1114
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

53

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class J Fuseblocks
101-200A

3.1"

3.06"

.75"
C'Bore

6.125"

7.00"

.31"

.5"

3.15"

8.31"
.75"

3"
2"

.344" Dia. hole thru
.750 Dia. c'bore

6.125"
1.69"

.34"
DIA.

.750"
FIGURE 7.

FIGURE 6.

201-400A
10.51"

4"
3"
1.75"

.56"

.625"

3.5"

7.50"

.75"
C'Bore
.34"
DIA.

7.5"

4.00"

9.00"
6.00"

1"

.344" Dia. hole thru
.750 Dia. c'bore

2.00"

.50"

.5"

1.00"
FIGURE 8.

FIGURE 9.

401-600A

4.99"
4"
1.75"
1.125"

4.987"

14.144"

1"

11.00"

.56"

3.25"
.344" Dia.
hole thru
.750 Dia.
c'bore

8.875"

8.875"
2.375"

.75"
C'Bore
.34" Dia.

FIGURE 10.

2.88"

FIGURE 11.

.50"

1.00"

Data Sheet: 1114

54

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class J Fuseblocks

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.

JP Series

For use with Class J Fuses
(Bussmann LPJ,JKS).
Pyramid Style Fuseblock
Ampere Rating: 30A
Voltage Rating: 600V
Withstand Rating: 200,000 RMS Sym. Amps
Agency Information:
UL Listed, U.L. 512, Guide IZLT, File E14853
CSA Certified, C22.2 No. 39, Class 4225-04, File 47235
Material: Thermoplastic
UL Flammability: UL 94V0

Dimensional Data

Pyramid® J Fuseblock; 30A, 600V; 3-Pole; Panel or 35mm
DIN-Rail Mount; Clips with Reinforcing Springs
Mounting

Panel
With
DIN-Rail
Adapter*

Screws with
Pressure
Plate
JP60030-3PR
(#10-14 CU ONLY)
JP60030-3PRA
(#10-14 CU ONLY)

Catalog Numbers
Box
Aluminum
JP60030-3CR
(#2-14 CU/AL)
JP60030-3CRA
(#2-14 CU/AL)

Copper
Only
JP60030-3COR
(#2-14 CU ONLY)
JP60030-CORA
(#2-14 CU ONLY)

*Adapter Only for DIN-Rail - Cat No. JPA-3.

*All other dimensions (± 0.015∑)
(± 0.40mm)

DIN-RAIL MOUNTING SCREW 8" (203.2mm) APART
END STOPS - PREVENT BLOCK MOVEMENT WHEN CHANGING FUSES

4.00" MAX.
(101.6mm)

2.78"

3.06"

3.75" (±0.02)

(70.6mm)

(77.8mm)

(95.3mm (±0.50)

1.88"

(47.6mm)

3.13"

(79.5mm)

1.19"

ADAPTOR FOR 35mm
SYMMETRICAL DIN-RAIL MOUNTING

(30.2mm)

2.38"

(60.4mm)

3.29"

(83.6mm)

Data Sheet:1108
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

55

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Semiconductor Fuseblocks

J70100

Amps

Ampere Rating: 100A
Voltage Rating: 700V
Agency Information:
UL Recognized, Guide IZLT2, File E14853
Withstand Rating: 200,000 RMS Sym. Amps
For use with 22 ≈ 58mm fuses
(FWP-40A22F, FWP-100A22F, etc.)
Materials: Thermoplastic
UL Flammability: UL 94V0

Poles
1
2
3

100

Catalog Numbers
Box Lug w/
Fig.
Wire
Retaining Clip
No.
Range
J70100-1CR
1
#2-14 CU/AL
J70100-2CR
2
#2-14 CU/AL
J70100-3CR
3
#2-14 CU/AL

Dimensional Data
100A
1.702

3.202

.750

2.250

2.415

4.702
2.250

.750

C
L

4.005
CL

1.500
FIGURE 1

FIGURE 2

FIGURE 3

Data Sheet: 1211

56

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class J (Finger-Safe) Fuseholders
Safety J

JT(N)60030 and JT(N)60060
For use with Bussmann Class “J” fuses - (Bussmann LPJ, JKS)
Catalog Numbers:
JT60030 and JT60060 - Non-Indicating
JTN60030 and JTN60060 - Indicating (Neon)
Construction: Thermoplastic, UL Flammability; 94VO
Voltage Ratings: 600V
Amperage Rating: JT(N)60030 - 30A,
JT(N)60060 - 60A
Withstand Rating: 200,000A RMS Sym.
(Self Certified at 300,000A using Bussmann
LPJ_SP fuses)
Agency Information:
Listed to UL 512: Guide IZLT, File 14853
CSA Certified: Class 6225-01, File 47235

1.14
(29.0)

Indication: Min. voltage: 90 VAC, 115 VDC; Neon Lamp
“ON” when fuse opens, voltage source and current path
are present.
Finger-Safe: IP20 per IEC 60529
Terminations: 30A Dual Port Torque 20 lb. in.,
60A Single Port Torque 45 lb. in., Terminal Construction,
Tin plated Copper Alloy
Wire Size: JT(N)60030 - Rated for 75°C, AWG#18-#8;
CU only, JT(N)60060 - Rated for 75°C, AWG#14-#4;
CU only.
(Note: For JT(N)60030 use both stranded or solid, in a variety of
dual wire combinations of same wire size and type.)

Packaging: 12 in a carton
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

1.05
(26.7)

Slot

Din-rail

.07
(1.8)
MOUNTING
Shown without fuse
pullout cover

Dim. =

in.
(mm.)

2.75
(69.9)

1 pole
2 pole
3 pole

BUSS

BUSS

BUSS

JT60030
0 – 30A
600VAC

JT60030
0 – 30A
600VAC

JT60030
0 – 30A
600VAC

USE CLASS J
FUSES

USE CLASS J
FUSES

USE CLASS J
FUSES

DO NOT REMOVE
UNDER LOAD

DO NOT REMOVE
UNDER LOAD

DO NOT REMOVE
UNDER LOAD

1.23
(31.2)
2.42
(61.3)
3.60
(91.4)

2.52
(64.1)

JT60030
JTN60030

Data Sheet: 1152
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

57

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class J (Finger-Safe) Fuseholders

JT(N)600 Series fuseblocks can be dovetailed together within the same current rating to provide multiple pole block
configurations.
NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060.

1.31
(33.3)

1.25
(31.8)

Slot

Din-rail

.10
(2.6)
3.10
(78.7)

1 pole
2 pole
3 pole

MOUNTING

BUSS

BUSS

BUSS

JT60060
35 – 60A
600VAC

JT60060
35 – 60A
600VAC

JT60060
35 – 60A
600VAC

USE CLASS J
FUSES

USE CLASS J
FUSES

USE CLASS J
FUSES

DO NOT REMOVE
UNDER LOAD

DO NOT REMOVE
UNDER LOAD

DO NOT REMOVE
UNDER LOAD

1.52
(38.1)
2.96
(75.2)
4.40
(111.7)

Shown without fuse
pullout cover

Dim. =

in.
(mm.)

JT60060
JTN60060

3.06
(77.7)

Data Sheet: 1152

58

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class T Fuseblocks – 300V

T300

Class T Fuseblocks (300V) Catalog Data

(300V) For use with Class T Fuses
(Bussmann JJN)
Construction: Glass Polyester, Phenolic on 600A,
UL Flammability: 94VO
Rating: ⁄Ω™-600A
Withstand Rating: 200,000A RMS Sym.
Agency Information:
UL Listed UL512, Guide IZLT, File E14853
CSA Certified, Class 6225-01, File 47235.

Catalog Numbers
Screw

Box
Lug

2

T30030-2SR

T30030-2CR

3

T30030-3SR

T30030-3CR

4

T30030-4SR

T30030-4CR

2

T30060-2SR

T30060-2CR

3

T30060-3SR

T30060-3CR

4

T30060-4SR

T30060-4CR

1

—

T30100-1CR

2

—

T30100-2CR

3

—

T30100-3CR

1

—

T30200-1C

3

3

—

T30200-3C

4

201-400

1

—

T30400-1C

5

401-600

1

—

T30600-1C

6 (2) 600kcmil-4/0 CU-AL

Amps Poles
⁄Ω™-30

31-60

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

61-100

101-200

Dimensional Data
Figure 1. ⁄Ω™A to 60A
1.63"
0.72"
0.16"

0.69"

0.91"

X

1

1

2

Wire
Range
SR #10-18 CU
CR #6-14 CU-AL
CR #2-14 CU-AL
SR #10-18 CU ONLY

1/0-8 CU-AL

250kcmil-6 CU-AL
600kcmil-2/0 CU-AL

1.63"
0.72"
0.16"

A
B

1.20"

Fig.
No.

Z

0.91"

2.75" 2.5"

T30030-S
SECTION X-X

X

Z
0.44" Full
Radius
0.20"
C

T30060-C
SECTION Z-Z

Class T Fuseblocks (300V) Catalog Numbers
Dimensions (Inches)

Block
Type

A

B

C

T30030-2
T30060-2

2.41

—

1.03

T30030-3
T30060-3

3.44

1.03

2.06

T30030-4
T30060-4

4.47

2.06

3.09

Data Sheet: 1115
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

59

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class T Fuseblocks – 300V
Figure 2. 61A to 100A

Figure 3. 101A to 200A
1.69" (1 POLE)
3.09" (2 POLE)
4.5" (3 POLE)

2.06"
0.84"

6"

1.41" (2 POLE)
2.81" (3 POLE)
X

0.05"

3"
1.125"

Z

1.25"

2.25"

0.22" DIA.
2.25"
REF.

4.78"

1.69"

0.52" C'BORE
0.55" DEEP

2.39"

0.28" DIAMETER
0.63" C'BORE 0.5" DEEP

3.06"
2.56"
1.94"
0.81"

Z

X
0.38"
0.75"

Figure 5. 201A to 400A

Figure 4. 200A
4.87"

6"

1.695"

3"

.996"

2.25"

1.25"
1.125"
0.63"
A

0.28" DIAMETER
0.63" C'BORE 0.5" DEEP

2.75"

A

1.84"
0.282" DIAMETER THRU HOLE
0.625" C'BORE 0.438" DEEP

3.06"
2.38"

2.375"

0.81"

0.625"
4.46"

Figure 6. 401A to 600A
2.03"

5.75"
2.88"

1.5"

3.44"
2" 3"

3"
0.75"

0.33" DIAMETER
0.75" C'BORE 0.5" DEEP

Data Sheet: 1115

60

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class T Fuseblocks – 600V

Class T Fuseblocks (600V) Catalog Data

T600

(600V) For use with Class T Fuses
(Bussmann JJS)
Construction: Glass Polyester, Phenolic on 600A,
UL Flammability: 94VO
Rating: ⁄Ω™-600A
Withstand Rating: 200,000A RMS Sym.
Agency Information:
UL Listed UL512, Guide IZLT, File E14853
CSA Certified, Class 6225-01, File 47235.

Catalog Numbers
Screw

Box
Lug

1

T60030-1SR

T60030-1CR

2

T60030-2SR

T60030-2CR

3

T60030-3SR

T60030-3CR

1

T60060-1SR

T60060-1CR

2

T60060-2SR

T60060-2CR

3

T60060-3SR

T60060-3CR

1

—

2

—

T60100-2C

3

—

T60100-3C

1

—

T60200-1C

3

—

1B0089*

201-400

1

—

401-600

1

—

Amps Poles
⁄Ω™-30

31-60

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

61-100

101-200

1

2

Wire
Range
SR #10-18 CU
CR #2-14 CU-AL

CR #2-14 CU-AL
SR #10-18 CU ONLY

T60100-1C
3

2/0-14 CU-AL

4

250kcmil-6 CU-AL

T60400-1C

5

600kcmil-2/0 CU-AL

T60600-1C

6 (2) 600kcmil-4/0 CU-AL

* UL Listed, Guide IZLT, File E14853,
CSA Certified Class 6225-01, File 21455M18

Figure 1. ⁄Ω™A to 30A
1.44"
0.55"

0.5"

Fig.
No.

1.44"
0.33" 0.55"

2.59"
1.16"

0.33"

0.55"

3.75"
2.31"

0.33"

0.22" DIAMETER
0.5" C'BORE

0.33"
3.19"

1.563"

1.42"

Figure 2. 31A to 60A
1.75"
0.59"

0.5"

1.81"
0.63" 0.59"

3.34"
1.53"

0.63"

0.59"

4.86"
3.06"

0.63"

0.22" DIAMETER
0.5" C'BORE
2.94"

1.63"

1.47"

Data Sheet: 1116
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

61

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class T Fuseblocks – 600V
Figure 3. 61A to 100A
1.69" (1 POLE)
3.09" (2 POLE)
4.5" (3 POLE)
1.41" (2 POLE)
2.81" (3 POLE)

0.84"

X

0.78"

Z

0.22" DIA.
0.52" C'BORE
0.55" DEEP

2.34"
REF.

2.39"

Z

X
0.38"

SECTION Z-Z

0.75"

Figure 4. 101A to 200A

Figure 5. 201A to 400A

6"

0.05"

6"

3"

3"

1.125"
1.25"

2.25"

2.25"

1.25"
1.125"
2.5"

0.63"

0.28" DIAMETER
0.63" C'BORE 0.5" DEEP

0.28" DIAMETER
0.63" C'BORE 0.5" DEEP
2.72"

3.06"
2.56"
1.94"
0.81"

3.06"
2.38"
0.81"

Figure 6. 401A to 600A
2.95"

6.75"
3.38"

1.5"

3.44"
2" 3"

3"
0.75"

0.33" DIAMETER
0.75" C'BORE 0.5" DEEP

Data Sheet: 1116

62

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Class H(K), J and R Fuseblocks

Porcelain Type Fuseblocks

Modular Type Fuseblocks

Class H(K) and R Dimensions
Agency Information: UL Listed, Guide IZLT, File E14853

Class H & J Fuses
Reinforced retaining clips standard
Available in 30A and 60A, 3-pole models only.
Agency Information: UL Recognized, Guide IZLT2,
File E14853
CSA Certified, Class 6225-01, File 47235

Class H and K Dimension Fuseblocks - Porcelain Type
Fuseblocks
Terminal Type
Volts

250

Amps

Poles

Screw

Box Lug

⁄Ω¡º

1

2601

—

to

2

2604

—

30

3

2607

—

31

1

—

2602

to

2

—

2605

60

3

—

2608

600

Fuse
Type

Volts

Amps

250

60

H

⁄Ω¡º
to

Modular Type For Class H & J Fuses

1

2610

31
to

1

—

2611

60

J

600

Figure
Number

11241-3SR

11241-3PR

1

11242-3SR

11242-3PR

2

11241-3SR

11241-3PR

1

11242-3PR

2

11239-3SR

11239-3PR

1

11240-3SR

11240-3PR

2

30

11241-3SR

11241-3PR

1

60

11239-3SR

11239-3PR

1

60

30

Pressure

11242-3SR

30
600

—

Catalog Number
Screw

Note: Order two blocks per fuse (matched or mixed.)

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Figure 1

Figure 2

Notes:
1. 11239 and 11241 have wire terminals and mounting holes located under
fuse. (Figure 1)
2. 11240 and 11242 have wire terminals and mounting holes located at end
of fuse. (Figure 2)
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

63

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Class CC, Type M and Class G Fuseblocks

BC Series

BM Series

Class CC Fuseblocks
For use with Class CC Fuses
(Bussmann LP-CC, KTK-R, and
FNQ-R)
Construction:
Base - Thermoplastic
Clips - Bright tin-plated bronze
Ratings: 600V, 30A
Withstand Rating:
200,000A RMS Sym.
Agency Information:
UL Listed (Guide IZLT,
File E14853)
CSA (Class 6225-01, File 47235)
UL Flammability: 94VO
Dimensional Data:
See Data Sheet.
DIN-RAIL Adaptors: Page 200
DRA-1 & DRA-2

Type M
Supplementary Fuseblocks
For use with any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses
(Bussmann KTK, FNQ, FNM, BAF,
BAN, and AGU)
Construction: Thermoplastic
Ratings: 600V, 30A
Withstand Rating:
10,000A RMS Sym.
Agency Information:
UL Recognized (Guide IZLT2,
File E14853)
CSA (Class 6225-01, File 47235)
UL Flammability: 94VO
Dimensional Data:
See Data Sheet.
DIN-RAIL Adaptors: Page 200
DRA-1 & DRA-2

Poles

Terminal Type
Screw
Pressure
with
Plate w/
Quick
Pressure Quick
Box
Screw Connect* Plate
Connect* Lug

Amps

Poles

Terminal Type
Screw
Pressure
with
Plate w/
Quick
Quick
Connect*
Connect*

⁄Ω¡ º

1

BC6031S

BC6031SQ BC6031P BC6031PQ BC6031B

⁄Ω¡ º

1

BM6031SQ

BM6031PQ

BM6031B

to

2

BC6032S

BC6032SQ BC6032P BC6032PQ BC6032B

to

2

BM6032SQ

BM6032PQ

BM6032B

30

3

BC6033S

BC6033SQ BC6033P BC6033PQ BC6033B

30

3

BM6033SQ

BM6033PQ

BM6033B

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 1105

BCCM Series
For use with (2) Class CC Fuses and
(1) ⁄‹Ω£™⬙ x 1⁄Ω™⬙ Fuse.
Catalog Data
Terminal Type
Screw with
Quick Connect*
BCCM6033SQ

Pressure Plate
w/Quick Connect*
BCCM6033PQ

*Quick connect terminal rated for 20A max.

Data Sheet: 1106

64

Class G Fuseblocks
For use with Class G Fuses
(Bussmann SC)
Construction: (0-30) Thermoplastic
(35-60) Phenolic
Ratings: 600V, 0-20A
480V, 25-60A
Withstand Rating:
100,000A RMS Sym.
Agency Information:
UL Listed 35-60A (Guide IZLT,
File E14853)
UL Recognized 1-30A, (Guide IZLT2,
File E14853)
CSA (Class 6225-01, File 47235)
Dimensional Data:
See Data Sheet.
DIN-RAIL Adaptors: Page 200
DRA-1 & DRA-2

Catalog Data

Catalog Data

Amps

BG Series and G Series

Catalog Data
Box
Lug

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 1104
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Terminal Type
Screw
Pressure
with
Plate w/
Quick
Quick
Amps Poles Connect* Connect*

Box
Lug

Box Lug
w/retaining
clip

1

1

BG3011SQ BG3011PQ BG3011B

—

to

2

BG3012SQ BG3012PQ BG3012B

—

15

3

BG3013SQ BG3013PQ BG3013B

—

1

BG3021SQ BG3021PQ BG3021B

—

20

2

BG3022SQ BG3022PQ BG3022B

—

3

BG3023SQ BG3023PQ BG3023B

—

25

1

BG3031S

BG3031P

BG3031B

—

to

2

BG3032S

BG3032P

BG3032B

—

30

3

BG3033S

BG3033P

BG3033B

—

35

1

—

—

—

G30060-1CR

to

2

—

—

—

G30060-2CR

60

3

—

—

G30060-3C G30060-3CR

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 1106
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Modular Fuseholders

CH Series
Features:
• 10 ≈ 38 Dovetail design provides maximum flexibility in
assembling multiple poles
• Touchsafe design - No exposed contacts
• DIN rail mount (35mm)
• Optional open fuse indication lights
• Excellent for switchboard panel, control consoles, small
motors, transformers, and similar applications
• Handle/fusepuller to install and remove fuses easily
• Available in single and multi-pole configurations
• Circuit marking system (P/N CH10CL and CH10CM)
• Wire ready: Saves time as terminals are ready to accept wires.
• CE marking

Standards:
North American Class CC
Listed UL 512, Guide IZLT, File E14853
Certified CSA Std. C22.2 No. 39, Class 6225-01, File LR47235
North American Midget ⁄‹Ω£ ™∑ x 1 ⁄Ω™∑
UL Recognized 512, Guide IZLT2, File E14853
CSA Certified, Std. C22.2 No. 39, Class 6225-01,
File LR47235
European 10 ≈ 38 IEC 269-2-1
14 ≈ 51 IEC 269-2
UL Recognized, CSA Certified***
22 ≈ 58 IEC 269-2
UL Recognized, CSA Certified***
Recommended Buss® Fuse Types:
North American Class CC Fuses - LP-CC, FNQ-R, KTK-R
North American Midget Fuses - FNQ, KTK, AGU, KLM, BAF, BAN,
FNM, FWA, FWC, & FNQ
10 ≈ 38 European Fuses - C10M, C10G
14 ≈ 51 Fuses - FWX, FWH, FWP, NON, C14M, C14G
22 ≈ 58 Fuses - FWP, C22M, C22G

Specifications
Fuse Size (mm)
Voltage

UL/CSA
IEC
UL/CSA
IEC

Amperage

Wire Size
Wire Type (& Temp.)
Torque (in-lbs)
IP Rating
Contact Material (fuseclip)
Connector Material
Maximum Watts Loss of Fuse
Dual Wire Rating

10 ≈ 38

Description
1 Pole
1 Pole w/Indication
2 Pole
2 Pole w/Indication
3 Pole
3 Pole w/Indication
*Assembly Pins - 2 Poles
*Assembly Pins - 3 Poles
**Circuit markers
**Circuit marker labels
Spare Fuseholder

30A, 600V
North American
Class CC
Fuseholder
CHCC1
CHCC1I
CHCC2
CHCC2I
CHCC3
CHCC3I
CH102AP
CH103AP
CH10CM
CH10CL
5TPH

10 ≈ 38
600V
690V
30A
32A (See Watts Loss)
#8 - #18 CU only
Solid/Stranded (75°)
12 in-lbs
IP 20
Tin-plated copper
Steel
3W‡
Please consult factory

30A, 600V
North American
Midget
Fuseholder
CHM1
CHM1I
CHM2
CHM2I
CHM3
CHM3I
CH102AP
CH103AP
CH10CM
CH10CL
5TPH

32A, 690V
European
10 ≈ 38
Fuseholder
CH101
CH101I
CH102
CH102I
CH103
CH103I
CH102AP
CH103AP
CH10CM
CH10CL
5TPH

‡Refer to Data Sheets 720003, 720008, 720025 and 720028 for watts loss of
applicable fuses.
*CH102AP and CH103AP are packaged in quantities of ten pins. One pin is required to
gang units together, and rating multiple poles.
**CH10CM are packaged in quantities of ten. CH10CL are packaged in quantities of ten
sheets of labels.
***UL/CSA part numbers include U.L. suffix. (i.e. -14x51 with UL rating is CH141GUL for
a single pole device)

14 ≈ 51
750V***
660V
30A***
50A (See Watts Loss)
#6 - #14 CU only
Solid/Stranded (75°)
17.7 in-lbs
IP 20
Tin-plated copper
Steel
5W‡

Description
1 Pole
1 Pole w/UL markings
1 Pole w/microswitch
2 Pole
3 Pole
3 Pole w/microswitch
Handle Profile - 2 Poles
Handle Profile - 3 Poles

22 ≈ 58
750V***
660V
50A***
125A (See Watts Loss)
#1 - #14 CU only
Solid/Stranded (75°)
22.1 in-lbs
IP 20
Tin-plated copper
Steel
9.5W‡

14 ≈ 51
Part No.
Ctn. Qty.
CH141G
6
CH141GUL
6
CH141MSG
6
CH142G
3
CH143G
2
CH143MSG
2
CH142HCG
10
CH143HCG
10

22 ≈ 58
Part No.
Ctn. Qty.
CH221G
6
CH221GUL
6
CH221MSG
6
CH222G
3
CH223G
2
CH223MSG
2
CH222HCG
10
CH223HCG
10

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1151
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

65

Fuseblocks, Holders and Terminal Blocks

Bussmann®

For ⁄‹Ω£™∑ ≈ 1⁄Ω™ ∑ Fuses

3743

4421 and 4515

Add-on Fuseblocks for ⁄‹Ω£™∑ ≈
1⁄Ω™∑ (10.3mm ≈ 38.1mm) Fuses
UL Recognized Guide IZLT2,
File E14853
Block with One Pole. Single pole
blocks lock into each other and can
be added at any time. Each has a single end barrier. Molded phenolic base;
screw terminal; beryllium copper,
bright-dipped clips. Rated 30A, 600V.

Single Pole Fuseblocks for ⁄‹Ω£™∑
≈ 1⁄Ω™∑ (10.3mm ≈ 38.1mm) Fuses
Electrical Ratings: 30A, 250Vac
(or less)

3835
Series Multiple Pole Fuseblocks
for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ (10.3mm ≈
38.1mm) Fuses

No. 4421—Solder Terminals. Base
width fiΩ•∑ (15.9mm).
2.5"

No. 3742—End Barrier Only.

Silver-plated, beryllium copper clips.
Rated 30A, 250V. No side barriers.
Screw terminals. Phenolic base.

(63.5mm)

0.897"

0.19"

(22.78mm)(4.8mm)

1.63"
(41.3mm)

3835-1

No of
Poles
1

Base Length
Inches mm
¤‡Ω£™∑
21.4

3835-2

2

1⁄‹Ω¡§∑

46.0

3835-3

3

2¤fiΩ£™∑

70.6

3835-4

4

3‹Ω¢∑

95.2

3835-5

5

4¤‹Ω£™∑

119.9

3835-6

6

5⁄⁄Ω¡§∑

144.5

3835-7

7

6¤⁄Ω£™∑

169.0

3835-8

8

7fiΩ•∑

193.7

3835-9

9

8⁄·Ω£™∑

218.8

3835-10

10

9·Ω¡§∑

242.9

3835-12

12

11⁄Ω™∑

292.1

Cat. No.

0.84"

3742

2.56"

1.125"

0.25"

No. 3723—Marking Strip. Length is
9‹Ω•∑ (23.8cm). Block and end barrier.

*Base width — 2‹Ω¢∑ (69.9mm)

2.75"
(69.9mm)

2.56"

2.56"
(65.1mm)

0.897"

1.29"

0.500"

BUSS

No. 4515—Screw Terminals. Base
width ‹Ω¢∑ (19mm).

0.19"

(22.78mm) (4.8mm)

Note—Mounting screw hole diameter is 0.147∑
(3.7mm). Countersink, 0.312∑ (7.9mm). Max.
Mounting Screw No. 6.
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

0.323"

(65.1mm)

(8.2mm)

1.0"
0.25"

1.125"

0.25"

(25.4mm) (6.4mm)

(6.4mm)

(28.6mm)

0.78"
(19.8mm)

0.144"

1.34"
(34.1mm)

Note—Mounting screw hole diameter is
0.147∑ (3.7mm). Counterbore diameter,
0.636∑ (8.0mm) Max. Mounting Screw No. 6.
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Note—Mounting screw hole diameter is 0.148∑
(3.7mm). Countersink, 0.313∑ (7.9mm). Max.
Mounting Screw No. 6.
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 2104

66

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Modular Fuseblocks
BH Series
For use with Bussmann semiconductor fuses.
Base: Light weight, high temperature thermoplastic
Mounting Studs: Plated steel
Nut: Plated steel
Washer: Spring steel
Agency Information:
UL Recognized, Guide EZLT2, File No. E14853 up to
700V
CSA Certified, Class 6225-01, File No. 47235 up to 700V
Withstand Rating: 200,000A RMS Sym., or interrupting
rating of the fuse used, whichever is smaller.
Available Part Numbers

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

BH-0001

BH-1001

BH-2001

BH-3004

BH-0002

BH-1002

BH-2002

BH-3033

BH-0003

BH-1003

BH-2003

BH-3144

BH-0111

BH-1131

BH-2031

BH-3145

BH-0112

BH-1132

BH-2032

BH-0113

BH-1133

BH-0121

BH-2033
BH-3003

BH-0122

Data Sheet: (BH-0) 1200; (BH-1) 1201; (BH-2) 1202; (BH-3) 1203
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

67

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Box Cover Units for Plug Fuses
BOX COVER UNITS
SOU, SRU, SSU, SOW, SRW, SSW, SOX, SRX,
SSX, SOY, SRY, SSY, SSY-RL, SSY-L, STY, SCY,
SOY-B & SKA
• Plug-fuse Box Cover Units provide a simple inexpensive
way to protect small motors with Buss dual-element
FUSETRON Type T or FUSTAT Type S plug fuses.
• Box Cover Units are easily installed in standard electric
boxes.
• Using fuses sized at the ampere rating of a motor or
slightly larger, will provide optimum overload and shortcircuit protection.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Selection Data - Plug Fuse Box Cover Units
Box
Cover
Cat. No.
SOU
_________
SRU
_________

Receptacle
Outlet to Load

Fuseholder
Type Box

2⁄Ω¢∑ Handy

Single

Double

125V

250V

Switch
Control1

Switch
Light2

Motor
Size
(Max.)

General Data

Agency4
Listing/
Certification

X
‹Ω¢ HP
125V, 15A
UL, CSA ____
___________________________________________________________________________________________________________________
X
X
⁄Ω™ HP
125V, 15A
UL
___________________________________________________________________________________________________________________
____

5
X
X
⁄Ω™ HP
125Vac, (do not use on dc), 15A
UL, CSA
SSU
_____________________________________________________________________________________________________________________________________
____________
_
SOW
X
‹Ω
¢
HP
125V,
15A
UL,
CSA ____
_________
___________________________________________________________________________________________________________________

SRW
2‹Ω¢∑ Switch
X
X
⁄Ω™ HP
125V, 15A
UL
_________
__________________________________________________________________________________________________________
____________
_
SSW
X
X
⁄Ω
™
HP
125Vac,
(do
not
use
on
dc),
15A
UL, CSA
_________________________________________________________________________________________________________________________________________________
_
SOX
_________
SRX
_________

4∑ Octagon

X
‹Ω¢ HP
125V, 15A
UL, CSA ____
___________________________________________________________________________________________________________________
X
X
⁄Ω™ HP
125V, 15A
UL
___________________________________________________________________________________________________________________
____

SSX
X
X
⁄Ω™ HP
125Vac, (do not use on dc), 15A
UL, CSA
_____________________________________________________________________________________________________________________________________
____________
_
SOY
X
‹Ω¢ HP
125V, 15A
UL, CSA ____
_________
___________________________________________________________________________________________________________________
SRY
_________
SSY
_________
SSY-RL
_________
STY3
_________

X
X
⁄Ω™ HP
125V, 15A
UL
___________________________________________________________________________________________________________________
____
X
X
⁄Ω™ HP
125Vac, (do not use on dc), 15A
UL, CSA ____
___________________________________________________________________________________________________________________
4∑ Square

X
X
X
X
⁄Ω™ HP
125Vac, (do not use on dc), 15A
—
___________________________________________________________________________________________________________________
____
X
X
⁄Ω™ HP
125Vac, (do not use on dc), 15A
UL
___________________________________________________________________________________________________________________
____
125Vac, (do not use on dc),
SCY
X
X(2)
⁄Ω™ HP (2)
UL
can protect two motors, 15A
_________
___________________________________________________________________________________________________________________
____
SOY-B
X
‹Ω¢ HP
125V, protects two motors, 15A
UL
_____________________________________________________________________________________________________________________________________
____________
_
SKA
4⁄⁄Ω¡§∑ Square
X
X(15A)
2 HP
250V, 15A single phase
UL
_____________________________________________________________________________________________________________________________________
____________
1Switch turns power to fused load OFF or ON.
2Switch light indicates power to load (dark when switch OFF or fuse open).
3Double-pole switch opens both side of circuit. STY can be used for two separate

125V motors not larger than 1/2 HP with the common switch, or a single motor not

larger than 2 HP at 250V (Maximum of 150V to ground).
4UL Guide JAMZ, File IE6491; CSA Class 6225-01, File 47235.
5Weatherproof version available, Part No. SSN.

Data Sheet: 1129

68

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Printed Circuit Board Mount for 5mm ≈ 20mm Fuses

HTC-45M

HTC-50M

HTC-60M, HTC-65M

PCB Vertical Mount
250V, 6.3A, 2.5W
Bayonet Cap/Carrier
See specifications below

PCB Horizontal Mount
250V, 6.3A, 2.5W
Bayonet Cap/Carrier
See specifications below

250V, 6.3A
Body Material: Valox DR48
Terminals: Phosphor bronze

1.303"

Mounting Holes

(33.1mm)

1.303"
(33.1mm)

HTC-60M (2 Legs)

.102" Dia. Hole
(2.6mm)
.051" Dia. Hole

.051" _+ .002" Dia. (Typ.)
( 1.30 _+ .05mm)

Printed Circuit
Board

(9.0mm)

.394"

(10.0mm)
( 1.30 _+ .05mm)

(1.3mm)

.354"

.394"
_ .002" Dia. (Typ.)
.051" +

.591"
(15.0mm)

Mounting Holes

Printed Circuit
Board

.512"

(10.0mm)

(13.0mm)

.138"

.512"

.512"

(3.5mm)

(13.0mm)

(13.0mm)

HTC-65M (4 Legs)

S
FU E

S
FU E

.197"

.591"

(5.0mm)

(15.0mm)

.461"

.461"

(11.7mm)

(11.7mm)

.102" Dia. Hole
(2.6mm)
.051" Dia. Hole
(1.3mm)

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

.886"

.354"

(22.5mm)

(9.0mm)

.551"
(14.0mm)

.138"
(3.5mm)

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Data Sheet: 2110

Data Sheet: 2110

Data Sheet: 2110

Specifications
Terminals:
Molded Materials:

For HTC-45M, HTC-50M Tin-plated.
High temperature thermoplastic that meets the flammability ratings of UL 94VO;
Glow Wire Test: 960°C per IEC 695-2-1.
Solderability: In accordance with IEC 68-2-20.
Electrical: Contact Resistance: ≤ 10mΩ; Insulation Resistance: ≥ 10mΩ; Dielectric Strength ≥ 2000 Vac.
Shock Safety: PC2 (fuseholders).
Agency Information: HTC-45M, HTC-50M UL Recognized, (Guide IZLT2, File E14853; 6.3A, 250V; CSA Certified, (Class
6225-01, File 47235; 6.3A, 250V) SEMKO: (9226032; 6.3A, 250V).
Packaging: Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/).

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

69

Fuseblocks, Holders and Terminal Blocks

Bussmann®

PC Board Mount for 5mm ≈ 20mm and ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fuses
HBH-I (for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ fuses)
HBH-M (for 5mm ≈ 20mm fuses)

HBV-I (for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ fuses)
HBV-M (for 5mm ≈ 20mm fuses)

HBW-I (for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ fuses)
HBW-M (for 5mm ≈ 20mm fuses)

Horizontal Mount

Vertical Mount with
Stability Pins

Vertical Mount without
Stability Pins

0.510"

0.510"

0.437"
(11.1mm)

1.77"
(45.0mm)

0.480"
(12.2mm)

(13.0mm)

1.855"

1.855"

(47.0mm)

0.490"

(47.0mm)

HBW

HBV

(13.0mm)

0.040"

(12.4mm)

(1.05mm)

0.040"
(1.05mm)

0.197"
(5.0mm)

0.244"

0.040"
(1.0mm)

(6.2mm)

0.580"
(14.9mm)

0.140"

0.580"

(3.5mm)

(14.9mm)

0.200"
(5.0mm)

0.469"
(12.0mm)

0.050" Dia. 3 Holes
(1.3mm)

0.100" Dia. 4 Holes
(2.54mm)

0.600"
0.700"
0.250"

0.531"

(15.2mm)

0.531"

(13.5mm)

(13.5mm)

(17.8mm)

0.400"

(6.4mm)

Panel

0.200"
(5.0mm)

0.050" Dia. 2 Holes

(10.0mm)

0.050"
Dia. 2 Holes
(1.3mm)

(1.3mm)

PC Board

Panel

Data Sheet: 2118

PC Board

Panel

Data Sheet: 2118

0.400"
(10.0mm)

PC Board

Data Sheet: 2118

Fuseholder Caps (Fit all three shown above)

FBI
Specifications
Electrical Ratings:

Molded Material:
Fuse Carrier & Knob:
Mounting:
Environmental:
Agency Information:

FBM

UL — 16A @ 250V; CSA — 12A @ 250V; VDE — 6.3A @ 250V; SEMKO — 10A @ 250V
Insulation resistance — 10,000 megohm at 500Vdc. Contact resistance — less than 0.005 ohms
@ 20mV. Dielectric strength — over 200V/mil.
High dielectric molded phenolic with a UL 94VO flammability rating.
Spring-loaded, bayonet type. Tin plated brass. Screwdriver slotted.
“Kicked” terminals (all models) and stabilizer pins on HBV model for increased stability.
Maximum operating temperature — (-40°C to +85°C).
UL Recognized — Guide IZLT2, File EI4853;
CSA Certified — Class 6225-01, File 47235
VDE — 41421
SEMKO — 9308147 (HBH, HBV) 9222106 (HBW)

CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

70

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Panel Mounted for 5mm ≈ 20mm Fuses
HTC-30M

34.2mm

1.8mm

13.0mm

Ø16mm

Ratings: 250V, 6.3A, 2.5W
Screwdriver slot

14.00mm

3.0x0.51mm

Ø16mm

4mm
6.8mm

Data Sheet: 2110

11mm

HTC-35M

37.5mm

12.00mm +0.0
–0.1

3.0x0.51mm

Ø15mm

12.70mm +0.0
–0.1

Ø16mm

Ratings: 250V, 6.3A, 2.5W
Threaded cap

4mm
5.5mm

HTC-40M

Data Sheet: 2110

11mm

12.00mm +0.0
–0.1
12.70mm +0.0
–0.1

3.0x0.51mm

Ø15mm

Ø22mm

37.5mm

Ratings: 250V, 6.3A, 2.5W
Screwdriver slot

6.5mm

Data Sheet: 2110

HTC-55M

36mm

12.70mm +0.0
–0.1

Ø15mm
0.5mm

4mm

5.5mm

11mm

35.5mm

HTC-70M

10.2mm

12.00mm +0.0
–0.1

Ø16mm
4.8x0.51mm

Ø15mm

Ratings: 250V, 10A, 2.5W
Fuse carrier: bayonet type

Data Sheet: 2110

0.5mm

4mm

5.5mm

11mm

12.70mm +0.0
–0.1

Ratings: 250V, 6.3A, 2.5W
Fuse carrier: bayonet type

12.00mm +0.0
–0.1

3.0x0.51mm

Ø16mm

Data Sheet: 2110

Specifications
Terminals:
Molded Materials:

Brass, tin-plated.
High temperature thermoplastic that meets the flammability ratings of UL 94VO; Glow Wire Test: 960°C
per IEC 695-2-1.
Solderability: In accordance with IEC 68-2-20.
Agency Information: UL Recognized — Guide IZLT2, File E14853;
CSA Certified — Class 6225-01, File 47235;
SEMKO — 9226031 (HTC-30M, HTC-35M); 9226032 (HTC-40M); 9226033 (HTC-55M); 9226034
(HTC-70M)
Electrical: Contact Resistance: ≤ 10mΩ; Insulation Resistance: ≥ 10mΩ; Dielectric Strength ≥ 2000 Vac.
Shock Safety: PC2 (fuseholders).
Packaging: Standard Qty 10 (No Prefix), Bulk Qty 100 (Prefix Catalog Number with BK/).
CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

71

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Panel Mounted for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses

HKP, HKP-L, HKP-W
Standard Fuseholders

HKP-BBHH, HKP-HH
and HKP-LW-HH

HKP-OO
Snap-Lock Fuseholders

Fuseholders with ⁄/¢∑ Quickconnects

Electrical Ratings for HPF Series

Electrical Ratings for HPF Series

Electrical Ratings for HPF Series

Catalog
Symbol Amps Volts

Fuse Description

Catalog
Symbol

Catalog
Symbol

HKP

30

250

—

HKP-BBHH

15

HKP-L

30

250

HKP with 2250V stand-off
barrier.

HKP-HH

15

250

HKP with ⁄Ω¢∑ quick-connect.

HKP-W

30

250

HKP with drip-proof knob.

HKP-LW-HH 15

250

HKP with drip-proof knob,
2250V stand-off barrier and
quick-connects.

Amps Volts

2.31"

Fuse Description

250

HKP with ⁄Ω¢∑ quick connects,
nut and washer assembled.

.75"

0.463"
REF.

0.69"

F
E

FU

SE

US

FUSE

E
US

FU

HKP with snap-lock.

(19.1mm)

0.69"

(17.5mm)

Fuse Description

2.64"

(19.1mm)

0.69"

250

1.56"
(39.7mm)

2.44"

0.75"

F

30

WHEN FUSE IS INSERTED

(58.7mm)

SE

Amps Volts

HKP-OO

.855"
(21.7mm)

1.17"

FUSE

.800"
(20.3mm)

Punched Mounting Hole

Punched Mounting Hole

Drilled Mounting Hole
#41 DRILL
0.5" DRILL

.505" + .005"

Punched Mounting Hole
.890"
(22.6mm)

.505" + .005"

(12.8mm + .13mm)

(12.8mm + .13mm)

.473" + .005"

.473" + .005"

(12.0mm + .13mm)

(12.0mm + .13mm)

Data Sheet: 2106

0.27"

.811"
(20.6mm)

Data Sheet: 2106

Data Sheet: 2106

Specifications
Terminals:

Bayonet-type knob.
Vibration resistant.
For panels up to fiΩ¡§∑ (7.9mm) thick.
Agency Information: UL Recognized — Guide IZLT2, File E14853
CSA Certified — Class 6225-01, File 47235
Replacement Parts: Knob: 9435-⁄/™∑
Plastic Nut: BK/1A4287
Metal Nut: BK/1A4806-2
Washer: 9732
CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

72

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Panel Mounted for 5mm ≈ 20mm and ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses

HTB Series
Fuseholders with Knob-Type Carriers
Agency Information:
UL Recognized — Guide IZLT2, File E14853
20A (‹Ω¡ §⬙ quick-connect 15A) @ 250V
CSA — 16A @ 250V Class 6225-01 File 47235;
VDE* — 6.3A @ 250V, 49890
SEMKO* — 6.3A @ 250V, 8945092, 9005230
*Screwdriver slot carrier only
Electrical Data: Insulation resistance (per IEC #257) —
10,000 ohms @ 500Vdc; contact resistance (per IEC #257) —
0.005 ohms max. @ 1A; standoff voltage (per IEC #257) —
480V/Mil @ .125 in. thickness.

Environmental: Maximum operating temperature
-55°C to 85°C.
Molded Components: High temperature, flame retardant,
thermoplastic; UL Component Recognized; 94VO; mounting
nut, spacer-black polycarbonate.
Terminals: Tin-plated brass.
Mounting: Withstands 15 to 20 lbs-ins torque to mounting
nut when mounting fuseholder to panel. Maximum panel
thickness 0.300 inches.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data
Terminal Options
Knob Type Carrier

Solder/
‹Ω¡ §∑ Quick-Connect

Common Dimensional Data:
Length (Knob Type) - 1.69∑
(42.9mm) Plus In-Line Terminal
(Screwdriver Slotted)
1.75∑ (44.5mm)
NOTE: Plus In-Line Terminal
0.47"

1.125"

(11.9mm)

(28.6mm)

Maximum
Panel
Thickness

In-Line

Rt. Angle

Carrier Options
⁄Ω¢∑ Quick-Connect
In-Line

Rt. Angle

Knob

0.34"

0.33"

(8.7mm)

(8.3mm)

0.47"
(11.9mm)

0.09" NOM.
(2.4mm)

0.69"

0.91"

(17.5mm)

(23.0mm)

5mm x 20mm
(“M” Equals Metric)
Knob

0.45"
(11.5mm)

HTB-22I

HTB-24I

HTB-26I

HTB-28I

✓

—

HTB-22M

HTB-24M

HTB-26M

HTB-28M

—

✓

HTB-42I

HTB-44I

HTB-46I

HTB-48I

✓

—

HTB-42M

HTB-44M

HTB-46M

HTB-48M

—

✓

HTB-62I

HTB-64I

HTB-66I

HTB-68I

✓

—

HTB-62M

HTB-64M

HTB-66M

HTB-68M

—

✓

HTB-82I

HTB-84I

HTB-86I

HTB-88I

✓

—

HTB-82M

HTB-84M

HTB-86M

HTB-88M

—

✓

0.30∑
7.62mm
Low Profile
Rear Hex Nut

⁄Ω¢∑ x 1⁄Ω¢∑
(“I” Equals Inches)

HTB-2

0.125∑
3.18mm

High
Profile
Rear Hex Nut

HTB-4

0.67"

0.92"

(17.1mm)

(23.4mm)

0.30∑
7.62mm
Front
Hex Nut

HTB-6

0.47"

1.125"

(11.9mm)

(28.6mm)

0.125∑
3.18mm
Low Profile
Snap-In

HTB-8

Fuseholders and fuse carriers may be ordered separately.

Data Sheet: 2119
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

73

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Panel Mounted for 5mm ≈ 20mm and ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses
HTB Series
Fuseholders with Screwdriver Slotted Carriers

Dimensional Data
Terminal Options
Knob Type Carrier

Common Dimensional Data:
Length (Knob Type) - 1.69∑
(42.9mm) Plus In-Line Terminal
(Screwdriver Slotted)
1.75∑ (44.5mm)
NOTE: Plus In-Line Terminal
0.17"

1.58"

(4.37mm)

(40.03mm)

Carrier Options

Solder/
‹Ω¡ §∑ Quick-Connect
Maximum
Panel
Thickness

In-Line

⁄Ω¢∑ Quick-Connect

Rt. Angle

In-Line

Rt. Angle

⁄Ω¢∑ ≈ 1⁄Ω¢∑
(“I” Equals Inches)
Screwdriver

0.34"
(8.7mm)

0.47"

0.33"

0.45"

HTB-32I

HTB-34I

HTB-36I

HTB-38I

✓

—

HTB-32M

HTB-34M

HTB-36M

HTB-38M

—

✓

HTB-52I

HTB-54I

HTB-56I

HTB-58I

✓

—

HTB-52M

HTB-54M

HTB-56M

HTB-58M

—

✓

HTB-92I

HTB-94I

HTB-96I

HTB-98I

✓

—

HTB-92M

HTB-94M

HTB-96M

HTB-98M

—

✓

0.30∑
7.62mm
Low Profile
Rear Hex Nut

HTB-3

0.41"

1.34"

(10.31mm)

(34.13mm)

Screwdriver

(11.5mm)

(11.9mm)

(8.3mm)

5mm ≈ 20mm
(“M” Equals Metric)

0.125∑
3.18mm
High Profile
Rear Hex Nut

HTB-5

0.17"

1.59"

(4.37mm)

(40.08mm)

0.125∑
3.18mm
Low-Profile
Snap-In

HTB-9

Fuseholders and fuse carriers may be ordered separately.

Ordering Information
FUSE CARRIER ONLY
HTB-

Packing
(Blank) – Std.
BK/ – Bulk

S

Product
Symbol

Body Configuration and Mounting
Finger Grip Holders
2 — Low Profile (Rear Panel Hex-Nut)
4 — High Profile
* 6 — (Front Panel Hex-Nut)
8 — Low Profile (Snap-In)
Screwdriver Slotted Holders
3 — Low Profile
5 — High Profile
9 — Low Profile (Snap-In)

Fuse Carrier
I — ⁄Ω¢∑ x 1-1⁄Ω¢∑
M — 5mm x 20mm
Rear Terminal Configuration
2 — Solder / ‹Ω¡§∑ Quick-Connect
(In-Line)
4 — Solder / ‹Ω¡§∑ Quick-Connect
(Right Angle)
6 — ⁄Ω¢∑ Quick-Connect (In-Line)
8 — ⁄Ω¢∑ Quick-Connect (Right Angle)

P

Splash Proof
(Optional on -2,
-4, -6, and -8)

Packaging
(Blank) – Std.
BK/ – Bulk

Product
Symbol
FT — Knob Type
(For 20, 40, 60,
and 80 Series
Only)
ST — Screwdriver
Slotted (For 30,
50, and 90 Series
Only)

Fuse Carrier
I — ⁄Ω¢∑ x 1⁄Ω¢∑
M — 5mm x 20mm

*Profile varies with panel thickness. Holder installs thru rear of panel.

Data Sheet: 2119

74

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Panel-Mounted for Indicating Type Fuses

HLD

HJL

HK Series

Pin Indicating
for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses
Voltage Rating: 250V, 15A
Agency Information:
UL Recognized, (File E14853,
Guide IZLT2)

Lamp Indicating
for ⁄Ω¢∑ ≈ 1∑ Fuses
Voltage Rating: 250V, 15A
No Agency Information

Lamp Indicating
for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses
Voltage Rating: 250V, 15A or 20A
Agency Information:
UL Recognized, (Guide IZLT2,
File E14853)
CSA Certified (Class 6225-01,
File 47235)

2.81"

2.5" (HLD)

(71.4mm)

(63.5mm)

1.19"

2.81"

(30.2mm)

(71.4mm)

Flat-Sides

0.69"

1.19"
(30.2mm)

(17.5mm)

0.81"
(20.6mm)

Octagonal Sides

2.75" (HLD-HH)
(69.9mm)

0.81"
(20.6mm)

Octagonal Sides

Punched Mounting Hole

Octagonal Sides

Punched Mounting Hole

.505" + .005"

(16.0mm + .13mm)

Punched Mounting Hole

.630" + .005"

(16.0mm + .13mm)

.630" + .005"

(16.0mm + .13mm)

.473" + .005"

.590" + .003"

(12.0mm + .13mm)

(14.6mm + .08mm)

.573" + .003"

(14.6mm + .08mm)

Electrical Ratings
Symbol

Electrical Ratings

Electrical Ratings

Amps

Volts

Features

HLD

15

250

Solder terminals

HLD-HH

15

250

⁄Ω¢ ∑ quick-connect terminals

Symbol
HJL

Amps
15

Use w/GBA, GLD Fuses

Lamp
Volts
90 to
250

Knob

Type
Neon

Color Type
Clear

Oct

Use w/AGX, MKB Fuses
For panels up to ⁄Ω•∑ thick.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Symbol
HKL*
HKL-X*
HKR
HKT
HKU
HKX

Amps

Lamp
Volts

Knob

Type Color

15

90 to 250 Neon

20

22 to 30
13 to 22
4 to 6
22 to 33

**
**
**
**

Clear
Amber
Red
Amber

Type
Oct
FS
Oct
Oct
Oct
FS

* UL Recognized and CSA Certified
** Incandescent

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Data Sheet: 2120

Data Sheet: 2121

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 2105

75

Bussmann®

Fuseblocks, Holders and Terminal Blocks

In-Line Fuseholders for ⁄Ω¢ ∑ ≈ ‡Ω• ∑ to 1⁄Ω¢ ∑ Fuses

HFB

HHB

HRK

Waterproof In-Line Fuseholder
for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses
Voltage Rating: 32V, 30A
Construction:
Body - Thermoplastic rubber;
Contacts - Copper tin plated

Universal In-Line Fuseholder
for ⁄Ω¢∑ ≈ ‡Ω•∑, 1∑ and 1⁄Ω¢∑ Fuses
Voltage Rating: 32V, 30A
Construction:
Body - Nylon;
Contacts - Copper tin plated
Pull Force: 5 lbs. minimum to separate fuseholder housing with fuse
installed.
UL Flammability Rating: 94 V2

Universal In-Line Fuseholder
for ⁄Ω¢∑ ≈ ‡Ω•∑ to 1⁄Ω¢∑ Fuses
Voltage Rating: 32V, 15A

Catalog Numbers
Description

Catalog Number

Standard Pack (10-in)

HFB

Bulk Pack (20-in)

BK/HFB

Replacement Contact Clip

BK/1A2294

Electrical Ratings
Catalog
Symbol
HRK

Amps
15

Volts
32

Dimensional Data
2.19"

Catalog Numbers

(55.6mm)

Holder (Without Leads)

Dimensional Data

Fuse
Description
⁄Ω¢∑ diameter fuses
of different lengths.

0.75"
(19.1mm)

Description

Catalog Number

Standard Pack (10-in)

HHB

Bulk Pack (100-in)

BK/HHB

0.69"
(17.5mm)

1.56"
(39.7mm)

Holder With Pre-attached Lead
Wires

3"
(76.2mm)

(#14 Insulated)
0.75"
(19.1mm)

• Ideal for harsh environments:
• –40° to 150° temp. range
• Withstands many organic solvents
and rigorous shock and vibration.
• Accepts #12 to #18 wire leads
(not provided).
• Simple assembly.
• One-piece molded thermo-plastic.
• High visibility yellow color for easy
identification in dark or hard-toaccess locations.
• Important information molded into
body.
• See Data Sheet for recommended
crimp tools.

Data Sheet: 2102

76

Wire Color

19∑ Length

Yellow

BK/HHB-Y419

8∑ Length
BK/HHB-Y408

Red

BK/HHB-R419

BK/HHB-R408

Black

BK/HHB-B419

BK/HHB-B408

• Three springs furnished with fuseholder afford acceptance of ⁄Ω¢∑ fuses
of different lengths.
• Wire leads are staked and soldered to
the contacts of the fuseholder.
• Leads are 8∑ (203mm) long.
• Wire size - #14.

Dimensional Data
L

0.53"
(13.5mm)

Fuse Length

Fuseholder Length “L”

‡Ω•∑ (AGW)

2.100 Max.

1∑ (AGX)

2.250 Max.

1⁄Ω¢∑ (AGC, MDL)

2.420 Max.

• Accepts #12 to #16 wire leads (not
provided with basic fuseholder).
• See Data Sheet for recommended
crimp tools.

Data Sheet: 2103

0.38"
(9.5mm)

Data Sheet: 2111

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

In-Line Fuseholders

HR and HM Series

HFA Series

HHT Series

In-Line Fuseholders for SFE
and ⁄Ω¢∑ ≈ Various Length
Fuses
Voltage Rating: 32V, 20A
No agency listings.

In-Line Waterproof Fuseholders
for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses
Construction:
Body - Phenolic;
Contacts - Copper crimp leads
Voltage Rating: 250V, 20A
Agency Information:
UL Recognized, (Guide IZLT2,
File E14853)
UL Flammability Rating: 94VO

In-Line Fuseholders
for 5 x 15mm or 5 x 20mm
Fuses
Construction:
Body - Black Thermoplastic
Contacts - Brass
Wire - 16 awg, red

Electrical Ratings
Catalog
Symbol

Includes
Fuse

HRJ*

SFE-20

HRI

SFE-14

HRH

SFE-9

HRE

SFE-7⁄Ω™

HRG

SFE-6

HRF

SFE-4

HMJ**

Wire

19" of #14

Electrical Ratings
Amps
5
10

5 x 15mm
5 x 20mm

Volts
32
32

Electrical Ratings

Dimensional Data

Catalog
Symbol

Amps

Volts

Terminals

SFE-20

HFA

20

250

Crimp #12 - #16

HMI

SFE-14

HFA-HH*

20

250

⁄Ω¢ ∑ Q.C.

HMH

SFE-9

HME

SFE-7⁄Ω™

HMG

SFE-6

HMF

SFE-4

*No UL Recognition.

1/4" ± 1/32"

6-3/16" ± 1/4"

8" of #14

6-1/16" ± 1/4"

1.84"
(IN ASSEMBLED POSITION)

Dimensional Data
2.34"

WIRE LENGTH: 13" ± 0.5"

(59.5mm)

*Also available as in-line fuseholder only with lead wire contacts,
HRJ-LES-Fuse.
**Also available as in-line fuseholder only with lead wire contacts,
HMJ-LES-Fuse.

HHJ-A

For ⁄Ω¢  1⁄Ω¢ fuse, no wire or fuse included, accepts
#18 - #22 wire.

HHJ-B

For ⁄Ω¢  1⁄Ω¢ fuse, no wire or fuse included, accepts
#12 - #16 wire.

HHI-B

For ⁄Ω¢  1⁄Ω¡§ fuse, no wire or fuse included, accepts
#12 - #16 wire.

.800"

.600"

(20.3mm)

(15.2mm)

0.42" DIA.

1.84"

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Dimensional Data
2.19"
(55.6mm)

0.75"
(19.1mm)

0.69"
(17.5mm)

1.56"
(39.7mm)

0.38"
(9.5mm)

Data Sheet: 2122

Data Sheet: 2115

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 2138

77

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Panel-Mounted for ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses

HPF

HPS

Standard Fuseholders with
Screw-type Knob for
⁄‹Ω£ ™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses
Agency Information:
UL Recognized, (Guide IZLT2, File
E14853)
CSA Certified (Class 6225-01, File
47235)
Flammability Rating: UL 94HB
• Combination ⁄Ω¢∑ quick-connect/solder
terminals.

Standard Fuseholders with
Bayonet-type Knob for
⁄‹Ω£ ™∑ ≈ 1fiΩ¡§∑ to 1⁄Ω™∑ Fuses
Agency Information:
UL Recognized, (Guide IZLT2, File
E14853)
CSA Certified (Class 6225-01, File
47235)
Flammability Rating: UL 94HB
• Combination ⁄Ω¢∑ quick-connect/solder
terminals.
• The -EE, -JJ, -FF and -RR are UL
Recognized for applications requiring
branch circuit prtection.

With Fuse
2.81" Max.

E

SE F

USE

FU

(71.4mm)

1.00"

1.31"

1.78"

HPG and HPD
Standard Fuseholders with
Bayonet-type Knob for
⁄‹Ω£ ™∑ ≈ 1⁄Ω™∑ Fuses
Agency Information:
UL Recognized, (Guide IZLT2, File
E14853)
Flammability Rating: UL 94V0 - Fuseholder body
UL 94HB - Knob
HPG
HPG-EE

2.81"
(71.4mm)

0.88"
(22.2mm)

1.125"
(28.6mm)

With Fuse

(25.4mm) (33.3mm) (45.2mm)

2.81"

FUS

(71.4mm)

0.88"
(22.2mm)

1.125"

(22.2mm)

(4.6mm)

2.69" Max.

(28.6mm)

1.78"

(68.3mm)

.250" ± .003"
(6.35 ± .08mm)
(Typ.2)

(45.2mm)

Without Fuse
.250" ± .003"
(6.35 ± .08mm)
(Typ.2)

0.180"

0.80"

(4.6mm)

(20.2mm)

1.125"

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Electrical Ratings

Fuse Description

Electrical Ratings

600

1⁄Ω™∑ (38.1mm)

HPF-C

30(4)

600(4)

1⁄Ω™∑ (38.1mm) clear knob.

Catalog
Symbol

5

600

BBS, ⁄‹Ω£™∑  1‹Ω•∑ fuses.

HPS

15

600

SC 0-15, ⁄‹Ω£™∑  1fiΩ¡ §∑ fuses.

HPS-L

Amps Volts Fuse Description
30(3)(4)600
5

600

⁄‹Ω£™∑ 1⁄Ω™∑
BBS, ⁄‹Ω£™∑  1‹Ω•∑ fuses.

HPF-JJ

20

600

SC 20, ⁄‹Ω£™∑  1⁄‹Ω£™∑ fuses.

HPS-EE

15

600

SC 0-15, ⁄‹Ω£™∑  1fiΩ¡ §∑ fuses.

HPF-FF(2)

30(3)

480

SC 25 & 30, ⁄‹Ω£™∑  1fiΩ•∑
fuses.

HPS-JJ

20

600

SC 20, ⁄‹Ω£™∑  1⁄‹Ω£™∑ fuses.

HPS-F-EE(2)

15

600

HPF-RR

30(3)

600

KTK-R, LP-CC & FNQ-R Class
CC fuses.

Sleeve on body, leaded for
⁄‹Ω£™∑  1fiΩ¡ §∑ fuses.

HPS-FF(2)

30(3) 480

SC 25 & 30, ⁄‹Ω£™∑  1fiΩ•∑ fuses.

HPF-WT

30(3)

600

Splash-proof knob.

HPS-RR(2)

30(3) 600

600

Sleeve on body, leaded for
⁄‹Ω£™∑  1fiΩ¡ §∑ fuses.

KTK-R, LP-CC, FNQ-R Class
CC fuses.

HPF-F-EE(2) 15

(2)No CSA Certification
(3)20A max when used with quick connect terminals.
(4)HPF-C ratings for CSA-15A, 250V

(1)No UL Recognition
(2)No CSA Certification
(3)20A max when used with quick connect terminals.
(4)HPS rated at 25V for CSA

Data Sheet: 2114

Data Sheet: 2113

78

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

30(3)

HPF-EE

(64.3mm)

Without Fuse

HPF

HPF-L

2.41"

(28.6mm)

Electrical Ratings
Catalog
Symbol Amps Volts

HPD

0.88"

0.180" DIA.

Catalog
Symbol

Amps Volts

HPG

30(3)

HPG-EE

15

HPD

30(3)

600
600
600

Fuse Description
⁄‹Ω£™∑ x 1⁄Ω™∑ fuses
SC 0-15, ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑ fuses.
⁄‹Ω£™∑ x 1⁄Ω™∑ fuses

(3)20A max when used with quick connect terminals.

NOTE:
• HPG and HPG-EE has combination ⁄Ω¢∑ quickconnect/solder terminals on both side (load)
and rear (line) terminals.
• HPD has combination ⁄Ω¢∑ quick-connect/solder
terminal on side (load) terminal only. Rear (line)
terminal is 3/ ∑ shorter than HPG. Rear Terminal
solder only.
16

Data Sheet: 2108

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks,
Fuseblocks,Holders
Holdersand
and
Disconnect
Terminal Blocks
Switches

Panel-Mounted for ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses

HPM

HPC-D

HPS2

Standard Fuseholder with
Screw-type Knob for
⁄‹Ω£ ™∑ ≈ 1⁄Ω™∑ Fuses
Agency Information:
UL Recognized, (Guide IZLT2,
File E14853)
CSA Certified (Class 6225-01,
File 47235)
Flammability Rating: UL 94HB

Fuseholder with
Screw-type Knob for
⁄‹Ω£ ™∑ ≈ 1⁄Ω™∑ Fuses
Agency Information:
UL Recognized, (Guide IZLT2,
File E14853)
• Supplied with O-ring and panel
gasket.
Flammability Rating: UL 94HB

Catalog Symbol: HPS2
Description: Meets requirement of
UL 1598 that both poles be removed
simultaneously.
Fuse Type: 13/32” x 1-1/2”
Agency Information:
UL 512 recognized,
(Guide IZLT2, File E14853)
CSA certified: (Class 6225-01, File
47235)
Flammability Rating: UL 94V0
Terminals: 1/4” quick connect / solder
Electrical Rating: 30A @ 600V (20A
max when used with quick-connect
terminals.)

With Fuse

With Fuse

2.73"

2.48"

(69.5mm)

(63.1mm)

0.94"

0.88"

(23.8mm)

(22.2mm)

1.775"

1.41"

(45.1mm)

(30.6mm)

2.594"
(65.89mm)

0.180"
(4.6mm)

Without Fuse

1.120"
.250" ± .003"
(6.35 ± .08mm)

(30.5mm)

Electrical Ratings

Electrical Ratings

Catalog
Symbol Amps Volts

Description

Catalog
Symbol Amps Volts

⁄Ω¢∑ quick-connect/solder

HPC-D

30(3)

600

Mount in panels up to ⁄ Ω¢∑ thick.

HPC-DK(1)

15

600

⁄ Ω¢∑ quick-connect terminals.

HPM

30(3)

HPM-D

30(3)

600
600

Splash-resistant

knob(4)

(3)20A max when used with quick-connect terminals.
(4)HPM-D has ⁄Ω¢∑ quick-connect/solder terminal on rear (load) terminal
only. The side (line) terminal is ⁄Ω¢∑ quick-connect only.

Description

(1)No UL Recognition
(3)20A max when used with quick-connect terminals.

Catalog Symbol
HPS2
BK/HPS2

standard 10-in carton
bulk 100-in carton

Replacement knob - BK/9987SA

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Data Sheet: 2112

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Data Sheet: 2109

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 2140

79

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Tron® In-Line Fuseholders
Single Pole
Type SC Fuses

HEG Series

HEH Series

HEC Series

HEJ Series

In-Line Fuseholders
Single-Pole
Voltage Rating: 600V, 15A
Non-Breakaway Holders

In-Line Fuseholders
Single-Pole
Non-Breakaway Holders
Voltage Rating: 600V
Current Rating: 20A
(CSA - 15A)

In-Line Fuseholders
Single-Pole
Voltage Rating: 480V, 30A
Non-Breakaway Holders

In-Line Fuseholders
Single-Pole
Non-Breakaway Holders
Voltage Rating: 480V, 60A

For SC Fuses 0 to 15A,
480V (or less).
Fuse size ⁄‹Ω£™∑ ≈ 1fiΩ¡§∑.

For SC-25, & SC-30 Fuses
Fuse size ⁄‹Ω£™∑ ≈ 1fiΩ•∑.

For SC Fuses; 35A to 60A and
Type HVW fuses, ⁄Ω™ to 6A.
Fuse size ⁄‹Ω£™∑ ≈ 2⁄Ω¢∑.

For Type SC-20 Fuses; 20A,
600V (or less). Also fuse
types BBS & KTQ (nominal
size ⁄‹Ω£™∑ ≈ 1‹Ω•∑).

Data Sheet: 2124

Data Sheet: 2124

Single Pole
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses

Data Sheet: 2124

Data Sheet: 2123

Double Pole
KTK-R Fuses

⁄‹Ω£™∑ ≈ 1⁄Ω™∑ Fuses

HEB Series

HET Series

HEY Series

HEX Series

In-Line Fuseholders
Single-Pole
Voltage Rating: 600V, 30A

In-Line Fuseholders
Single-Pole

In-Line Fuseholders
Double-Pole
Voltage Rating: 600V, 30A

In-Line Fuseholders
Double-Pole
Voltage Rating: 600V, 30A

Optional Break-a-way receptacle, polarized, and accepting
Class CC branch circuit fuses
(Buss type KTK-R, FNQ-R &
LP-CC; 600V or less, 200,000A
interrupting rating).

For any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuse.
Typical fuse types: BAF, FNM,
FNQ, and KTK (⁄Ω¡º - 30A).

Data Sheet: 2126

Data Sheet: 2126

Typical fuse types: BAF, FNM,
FNQ, and KTK (⁄Ω¡º - 30A).

An HEB - Fuseholder with a
permanently installed solid
neutral. Easily identified by
white plastic coupling nut.

Data Sheet: 2127

Data Sheet: 2125

For any ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuse.

Note: For agency and CE information see the appropriate data sheet.

80

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

For HEB Holders Only
Directions:To select complete holder P/N, work from left to right starting with load terminal options and then line terminal options. Then determine breakaway or non-breakaway style.

Line Terminal
Terminal
Type

Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
Copper
Set-Screw
Copper
Set-Screw
Copper
Set-Screw
Aluminum
Set-Screw
Aluminum
Crimp
Aluminum
Crimp
Aluminum
Crimp
Aluminum
Crimp
Aluminum
Crimp

No. of
Terminal
Wire Size Wires per Solid Stranded
Wire
Wire
Type
Terminal

#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#12 to #8
#12
#6, #4
#10
#6, #4
#10
#6, #4
#10
#6, #4
#10
#4
#8
#2
#6

1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
Y
N
Y

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

#20, #18

1

Y

Y

#12 to #3

1

Y

Y

#12 to #3

1

Y

Y

#12 to #3

1

Y

Y

#12 to #3

1

Y

Y

#12 to #2

1

Y

Y

#8
#6
#6
#4
#3, #4
#2

1
1
1
1
1
1

N
Y
N
Y
N
Y

Y
N
Y
N
Y
N

#1, #2

1

N

Y

1/0

1

N

Y

1

Y

N

1

N

Y

SolidTerminal #8 to #12
for aluminum
connector
#10 to #14

(1)UL Recognized, Guide 12LT2,
(2)CSA Certified, Class 6225-01,
(3)CE

File E14853
File 47235

Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
Copper
set-screw
Aluminum
Set-Screw
Aluminum
Set-Screw
Aluminum
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Crimp
Copper
Set-Screw
Copper
Set-Screw
Aluminum
Set-Screw
Aluminum
Set-Screw
Aluminum
Set-Screw
Aluminum
Crimp
Aluminum
Crimp
Aluminum
Crimp
Aluminum
Crimp
Aluminum
Crimp

Available P/N’s

No. of
Wire Size Wires per Solid Stranded
Wire
Terminal Wire

#12 to #8
#12
#6 to #4
#10
#4
#8
#2
#6
2/0
#3

1
2
1
2
1
2
1
2
1
2

Y
Y
Y
Y
N
Y
N
Y
N
N

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

#12 to #3

1

Y

#12 to #3

2

#12 to #2

Non-Breakaway
P/N
(Boots not included)

HEB-AA(1)(2)
(3)

Breakaway
P/N
(Boots included)

HEB-AW-RLC-A(1)(2)
(3)

HEB-AB(2)

HEB-AW-RLC-B

HEB-AC(2)

HEB-AW-RLC-C

HEB-AD(2)

N/A

HEB-AE(2)

N/A

Y

HEB-AJ

HEB-AW-RLC-J

Y

Y

HEB-AK

HEB-AW-RYC

1

Y

Y

HEB-AL

HEB-AW-RLA

#12 to #2

2

Y

Y

HEB-AY

HEB-AW-RYA

HEB-AR

N/A

HEB-BA(2)

HEB-BW-RLC-A

HEB-BB(2)

HEB-BW-RLC-B

HEB-BC(2)

N/A

HEB-BD(2)

N/A

HEB-CC(2)

N/A

HEB-DD(2)

N/A

HEB-ZA

N/A

#1, #2

1

N

Y

#12 to #8
#12
#6, #4
#10
#4
#8
#2
#6
#4
#8
#2
#6
#12 to #8
#12

1
2
1
2
1
2
1
2
1
2
1
2
1
2

Y
Y
Y
Y
N
Y
N
Y
N
Y
N
Y
Y
Y

Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y

#12 to #3

1

Y

Y

HEB-JJ

HEB-JW-RLC-J

#12 to #3

2

Y

Y

HEB-JK

HEB-JW-RYC

#12 to #2

1

Y

Y

HEB-JL

N/A

#12 to #2

2

Y

Y

HEB-JY

N/A

#12 to #2

1

Y

Y

HEB-LL

HEB-LW-RLA

#8
#6
#6
#4
#3, #4
#2

1
1
1
1
1
1

N
Y
N
Y
N
Y

Y
N
Y
N
Y
N

HEB-NN

N/A

HEB-PP(2)

N/A

HEB-QQ(2)

N/A

#1, #2

1

N

Y

HEB-RR(2)

N/A

1/0

1

N

Y

HEB-TT(2)

N/A

1

Y

N

1

N

Y

HEB-SS

N/A

SolidTerminal #8 to #12
for aluminum
connector
#10 to #14

Contact your local Bussmann representative for other

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

81

Bussmann®

Fuseblocks, Holders and Terminal Blocks

In-Line Fuseholders for Automotive Blade-Type Fuses

HHC, HHD, HHF and HHG

HHL and HHM

HHX

In-Line Fuseholders for
ATC® Blade-Type Fuses
Voltage Rating: 32Vdc
Current Rating: See Table. Rated to
carry 80% of Fuse Rating continuously.

In-Line Fuseholders for
MINI-Fuses®
Voltage Rating: 32Vdc
Current Rating: See Table. Rated to
carry 80% of Fuse Rating continuously.

In-Line Fuseholders for
MAXI-Fuses™
Voltage Rating: 32Vdc
Current Rating: See Table. Rated to
carry 80% of Fuse Rating continuously.

Electrical Ratings

Electrical Ratings

Electrical Ratings

Catalog
Symbol Description
HHC
HHD
HHD-C

Fuse
Size

Yellow fuseholder 3-20A
Black fuseholder 3-30A
Cover only
Fits HHD
only
Black fuseholder 3-20A
with cover
Black fuseholder 3-30A
with cover

HHF
HHG

Electrical
Connection

Catalog
Symbol

#16 black leadwire
#12 yellow leadwire
Clear polycarbonate

HHL

HHL-B

HHM
#12 yellow leadwire
HHM-B

Description

Fuse
Size

BK/HHC-R Yellow fuseholder 3-20A
BK/HHF-B Black fuseholder 3-20A
with cover

Black fuseholder
w/cover

2-20A

Black fuseholder
– body only

2-20A

Black fuseholder
w/cover

2-30A

Black fuseholder
– body only

2-30A

#16 yellow leadwire

Bulk Products
(Bulk Quantity - 1000 Pieces)
Catalog
Symbol

Description

Fuse
Size

Electrical
Connection
#16 red leadwire
#16 black leadwire

A fuse must be properly and fully inserted into
the holder to provide a solid connection. Poor or
improper insertion of the fuse can result in failure
of the fuse and holder, thus not protecting the
device for which it was intended.
0.78"
0.364"

HHM-C

Electrical
Connection

Catalog
Symbol

#16 black leadwire, 4” length
stripped to ⁄Ω¢”
#16 black leadwire, 4” length
stripped to ⁄Ω¢”
#12 red leadwire,
4” length
stripped to ⁄Ω¢”
#12 red leadwire,
4” length
stripped to ⁄Ω¢”

HHX

Black cover only

HHX-B
HHX-C

Description

Fuse
Size

Black fuseholder
w/cover

20-60A

Black fuseholder
– body only

20-60A

Electrical
Connection
#6 red leadwire,
5” with
blunt ends
#6 red leadwire,
5” with
blunt ends

Black cover only

A fuse must be properly and fully inserted into
the holder to provide a solid connection. Poor or
improper insertion of the fuse can result in failure
of the fuse and holder, thus not protecting the
device for which it was intended.

Bulk Products
(Bulk Quantity - 1000 Pieces)
Catalog
Symbol
BK/HHL-R

Description
Black fuseholder
– body only

Fuse
Size

Electrical
Connection

2-20A

#16 red leadwire,
4” length
stripped to ⁄Ω¢”

A fuse must be properly and fully inserted into
the holder to provide a solid connection. Poor or
improper insertion of the fuse can result in failure
of the fuse and holder, thus not protecting the
device for which it was intended.

0.91"
0.5"
0.38" 0.30"

0.25"

4.0" + 0.25"

Data Sheet: 2107

82

1.125"

4.0" + 0.25"

Data Sheet: 2128

Data Sheet: 2129

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

For ⁄Ω¢ ∑ ≈ 1⁄Ω¢ ∑ Fuses
4405

4406

Series 8000
Bolt-in and Snap-in Mounting for ⁄Ω¢∑ ≈ 1⁄Ω¢∑ Fuses
Construction: Blocks are molded flame retarded thermoplastic. Clips are spring-bronze.
Voltage Rating: 300V
Agency Information:
UL Recognized ; File E14853A, Guide IZLT2
CSA Certified Class 6225-01, File 47235
Anti-Rotation Pin: Single pole blocks may be ordered without the antirotational pin simply
by adding an “X” to the number of poles (Example: BK/S-8000-1X).
Carton Quantity: 10; shelf package: 100.
Bulk Carton: Single-pole and 2-pole fuse blocks–1,000; Multiple-pole fuse blocks–3-8 pole:
200; 9-12 pole: 50. When ordering bulk quantities, prefix “BK/” to catalog number: (Example:
BK/S-8001-1-SNP).

⁄Ω¢∑ ≈ 1⁄Ω¢∑ Single Pole
(6.4mm ≈ 31.8mm)
Bakelite base; spring-bronze, bright
tin-lead plate clips; 30A, 250V; base
width ⁄Ω™∑ (12.7mm).
No. 4405—0° Solder Terminals.
Integral terminal and clip.
2.31"
(58.7mm)

0.27"

0.69"
(17.5mm)

(6.7mm)

1.63"
(41.3mm)

Bolt-in Mounting
Series

Terminal

Angle

Basic
Cat. No.

Amperes

Poles
(Suffix)

8000

Solder

0°
40°

S-8001S-8002-

UL 25A
CSA 21A

8100

‹Ω¡§∑ Quick
Connect

0°
40°

S-8101S-8102-

UL 20A
CSA 13A

8200

⁄Ω¢∑ Quick
Connect

0°
40°
Side

S-8201S-8202S-8203-

UL 20A
CSA 16A

8300

Screw

—

S-8301-

UL 30A
CSA 25A

Series

Terminal

Angle

Cat. No.

Amperes

Poles
(Suffix)

8000

Solder

0°
40°

S-8001-1-SNP
S-8002-1-SNP

UL 25A
CSA 21A

Available

8100

‹Ω¡§∑ Quick
Connect

0°
40°

UL 20A
CSA 13A

8200

⁄Ω¢∑ Quick
Connect

0°
Side

S-8101-1-SNP
S-8102-1-SNP
S-8201-1-SNP
S-8203-1-SNP

1.63"
(41.3mm)

0.69"

1 - 12

Snap-in Mounting

Catalog Code
BK/ S-8 0

00

UL 20A
CSA 16A

No. 4406—Side Solder Terminal
No. 4574—Spare Fuseblock

(17.5mm)

No. 2499—Side Quick-Connect
Terminals. ⁄Ω¢∑ (6.4mm); 15A, 250V.
UL Recognized,
Guide IZLT2, File E14853.

only in

1.63"

0.75"

(41.3mm)

(19.1mm)

0.27"
0.72" (6.7mm)

(18.3mm)

single
pole

0.5"
(12.7mm)

Note—Mounting screw hole diameter is 0.147∑
(3.7mm). Counterbore diameter, 0.636∑ (8.0mm).
Max. Mounting Screw No. 6.

-00

Prefix for
Bulk
Packing
Series 8000
Product Line
Type Terminal
“0”-Solder
“1”-‹Ω¡§∑ Quick Connect
“2” - ⁄Ω¢∑ Quick Connect
“3” - Screw
Terminal Angle
“01” - straight (0°,)
“02”- 40°
“03” - side*
Number of Poles (1-12)

0.27"
(6.7mm)

2499

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

*Available only in single pole

4574

Data Sheet: 2101
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

83

Bussmann®

Fuseblocks, Holders and Terminal Blocks

For ⁄Ω¢ ∑ ≈ 1∑ Fuses

Series 3828

4520 and 4393

Solder Terminals Fuseblock for ⁄Ω¢∑ ≈ 1∑ Fuses
(6.4mm ≈ 25.4mm)

Single Pole Fuseblock for ⁄Ω¢∑ ≈ 1∑ Fuses
Bakelite base; Width ⁄Ω™∑ (12.7mm). Spring-bronze, bright
tin-lead plated clips. Rated 30A, 250V.
No. 4520—Solder terminals; straight; integral clip and
terminal.

1.88"
(47.6mm)

0.63"

1.94"

(15.9mm)

(49.2mm)

.188"
.598" (4.8mm)

0.19"

1.38"

(4.8mm)

(34.9mm)

(15.2mm)

1.38"
(34.9mm)

Catalog And Dimensional Data
Catalog
Number

No. of
Poles

*Base Length

No. 4393—Spare fuseblock.

inches

mm
12.7

Note—Mounting screw hole diameter is 0.147∑ (3.7mm), counterbore
0.636∑ (8.0mm) diameter. Max. Mounting Screw No. 6.

3828-1

1

⁄Ω™

3828-2

2

1⁄ Ω•

28.6

3828-3

3

1‹Ω¢

44.5

1.38"

3828-4

4

2‹Ω•

60.3

(34.9mm)

3828-5

5

3

76.2

3828-6

6

3fiΩ•

92.1

3828-7

7

4⁄Ω¢

108.0

3828-8

8

4‡Ω•

123.8

3828-10

10

6⁄Ω•

155.6

3828-12

12

7‹Ω•

187.3

.598"
(15.2mm)

.188"
(4.8mm)

*Small phenolic base, base width 1‹Ω •∑ (34.9mm)

Note—Mounting screw hole diameter is 0.147∑ (3.7mm) Max. Mounting
Screw No. 6.

84

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Printed Circuit Board for 5mm Diameter Fuses
HTC-15M, HTC-140M

.217"
1.047"

PCB Fuseblock and Snap-On Cover
Voltage Rating: 250V, 6.3A, 1.6W
HTC-15M (Fuseholder), HTC-140M (Natural Cover),
HTC-150M* (Transparent Cover)

(26.6mm)

.345"

.531"

(9.0mm)

(13.5mm)

HTC-140M
Cover

.571"
(14.5mm)

(5.5mm)

Mounting Holes
.890"

.866"

(22.60mm)

(22.0mm)

_ .002" Dia. (Typ.)
.059" +

.177"

217"

+ .05mm)
(1.50 _

(4.5mm)

*Available in bulk only. Use this format: BK/HTC-150M

PC Board Mount Fuseclip
Construction: Tin plated bronze
Tape and Fan Fold packed
Ammo Pack (AP/HTC-200M) 1000 pieces per box

.319"

.50"

(8.1mm)

(12.7mm)

BUSS

.177"
(4.5mm)

BUSS

HTC-200M

BUSS

Data Sheet: 2110

.157"
(3.99mm)

.929"
(23.6mm)

.61"
(15.5mm)

.031"
(.79mm)

.012"

.217"

(.3mm)

(5.5mm)

.50"

.50"

HTC-210M

Data Sheet: 2110

(12.7mm)

(12.7mm)

4.32mm

PC Board Mounted Fuseclip with End Stops
2.54mm

8.73mm

6.26mm

2.29mm

2.54mm

1.46mm

2.54mm

3.91mm

6.22mm
2.85mm

Data Sheet: 2110

1A3399 Series

.062"

.115"

Fuseclips with End Stops and Straight Leads
Catalog Number

Clip Material*

Finish

1A3399-01

Beryllium Copper*

Silver

1A3399-04

Beryllium Copper*

Bright Tin

1A3399-10

Spring Bronze

Bright Tin

.254"

.225"

.125"

(1.6mm)

(2.9mm)

(5.7mm)

(3.2mm)

.030"
(1.6mm)

.237"

(6.5mm)

(6.0mm)

.060"

.125"

(1.5mm)

(3.2mm)

.188"
(4.8mm)

Data Sheet: 2131

*Beryllium copper recommended for currents higher than 15 amps (⁄Ω¢∑ clips).

(

1A5018 Series

)

.180"

.440"

Fuseclips with End Stops and Straight Leads

(4.57mm)

(11.2mm)

High Profile
Catalog Number

Clip Material*

Finish

1A5018-7

Spring Bronze

Silver

1A5018-10

Spring Bronze

Bright Tin

.047"
(1.2mm)

.140"

.180"

(3.7mm)

(4.6mm)

.230"
(5.84mm)

Data Sheet: 2131

*Beryllium copper recommended for currents higher than 15 amps (⁄Ω¢∑ clips).

1A5601 Series

.246"

.344" + .015"

(6.3mm)

(8.73mm + 0.38mm)

Fuseclips (0-7A)

.250"
(6.35mm)

.344" + .015"

(8.73mm + 0.38mm)

Catalog Number

Clip Material

Finish

1A5601

Cartridge Brass

Bright Tin

.141" + .015"

(3.58mm + 0.38mm)

.060"

.266"

(1.5mm)

(6.75mm)

.022" + .002"

.032" + .002"

(0.56mm + 0.05mm)

(.81mm + .05mm)

Data Sheet: 2131

.219"

1A5602 Series

(5.57mm)

Fuseclips (0-7A)

.500"

.250"

(12.70mm)

Catalog Number

Clip Material

Finish

1A5602

Cartridge Brass

Bright Tin

(6.35mm)

.140"
(3.56mm)

.093"
(2.36mm)

.047"

.216"
(5.48mm)

LEGS TO FIT
IN .052" (1.3mm) DIA.
HOLES ON CENTER

(1.19mm)

Data Sheet: 2131

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

85

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Printed Circuit Board for ⁄Ω¢ ∑ Diameter Fuses
1A3398 Series
Fuseclips without End Stops and Straight Leads
Catalog Number

Clip Material

Finish

1A3398-07

Cartridge Brass

Bright Tin

1A3398-08

Spring Bronze

Bright Tin

.102" Dia.

.280"

(2.6mm)

(7.1mm)

.255"
(6.5mm)

.245"

.155"

(6.2mm)

(3.94mm)

.410"
(10.4mm)

.060"
(1.5mm)

.320"

.140"

.102" Dia.

.280"

(2.6mm)

(7.1mm)

.280"

(3.6mm) (7.1mm)

(8.13mm)

1A1907 Series
Fuseclips with End Stops and Straight Leads
Catalog Number
1A1907-02
1A1907-03
1A1907-05
1A1907-06
1A1907-08
1A1907-09

Clip Material*
Cartridge Brass
Beryllium Copper*
Beryllium Copper*
Cartridge Brass
Spring Bronze
Spring Bronze

Finish
None/Bright Dipped
Bright Tin
Silver
Bright Tin
None/Bright Dipped
Bright Tin

Data Sheet: 2131

.102 Dia.

.280

(2.6mm)

(7.1mm)

.255"
(6.5mm)

.245"

.155"

(6.2mm)

(3.94mm)

.410"
(10.4mm)

.060"
(1.5mm)

.320"

.140"

.102" Dia.

.280"

(2.6mm)

(7.1mm)

.280"

(3.6mm) (7.1mm)

(8.13mm)

Data Sheet: 2131

*Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips).

.245"

1A4533 Series
Fuseclips without End Stops and
Angled Out Leads
1A4533-01

Beryllium Copper*

Bright Tin

1A4533-06

Cartridge Brass

Bright Tin

(6.5mm)

1A4533-07

Spring Bronze

Bright Tin

.060"

Finish

*Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips).

.255"
.150"
(3.81mm)

(1.5mm)

.320"

.280"

(8.13mm)

(7.11mm)

.228"
(5.79mm)

.323"

Data Sheet: 2131

(8.20mm)

.245"

1A4534 Series

.155"

(6.2mm)

Fuseclips with End Stops and
Angled Out Leads

(3.94mm)

.102"
(2.6mm)

.410"

Catalog Number

Clip Material*

1A4534-01

Beryllium Copper*

Bright Tin

1A4534-06

Cartridge Brass

Bright Tin

1A4534-07

Spring Bronze

Bright Tin

(10.4mm)

Finish

*Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips).

.255"
(6.5mm)

.060"

.150"
(3.81mm)

(1.5mm)

1A1120 Series

.320"

.280"

(8.13mm)

(7.11mm)

.228"
(5.79mm)

.323"

Data Sheet: 2131

(8.20mm)

.265"
Finish
None/Bright Dipped
Silver
Bright Tin
Bright Tin
None/Bright Dipped
Bright Tin

.132"

(6.7mm)

Fuseclips without End Stops and Angled In Leads

(3.4mm)

.410"
(10.4mm)

.187"
(4.8mm)

.255"
(6.5mm)

.080"

(3.9mm)

(2.03mm)

(7.4mm)

.360"
(9.14mm)

Data Sheet: 2131

1A1119 Series

.285"

Clip Material*

Finish

1A1119-04

Beryllium Copper*

Bright Tin

1A1119-05

Beryllium Copper*

Silver

1A1119-10

Cartridge Brass

Bright Tin

1A1119-13

Spring Bronze

Bright Tin

*Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips).

.132"

(7.24mm)

Fuseclips with End Stops and Angled In Leads
Catalog Number

.312"
(7.9mm)

.290"
.155"

*Beryllium copper recommended for currents higher than 15A (⁄Ω¢∑ clips).

86

.102"
(2.6mm)

.410"

Clip Material*

Clip Material*
Cartridge Brass
Beryllium Copper*
Beryllium Copper*
Cartridge Brass
Spring Bronze
Spring Bronze

(3.94mm)

(10.4mm)

Catalog Number

Catalog Number
1A1120-02
1A1120-05
1A1120-06
1A1120-09
1A1120-11
1A1120-12

.155"

(6.2mm)

(3.4mm)

.420"
(10.67mm)

.187"
(4.8mm)

.250"
(6.5mm)

.080"
(2.03mm)

.290"
.155"
(3.9mm)

.312"
(7.9mm)

(7.4mm)

.360"
(9.14mm)

Data Sheet: 2131

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Printed Circuit Board Fuseclips
(

1A3400 Series

)

.470"

Fuseclips for ⁄‹Ω£™∑ diameter fuses with
End Stops and Straight Leads
Catalog Number

Clip Material

Finish

1A3400-09

Spring Bronze

Bright Tin

20A Maximum

.050"

.710"
(18.0mm)

.080"
(2.0mm)

.470"

.437"

(1.27mm) (11.1mm)

(11.9mm)

.218"
(5.5mm)

.142" Dia.
(3.6mm)

.380"
(9.7mm)

(11.9mm)

Data Sheet: 2131

1A5600 Series

.295"

Fuseclips for ATC® Fuses (0-20A)
Catalog Number

Clip Material

Finish

1A5600

Brass

Satin Finish Tin

(7.49mm)

.330"
(8.38mm)

.180"
(4.57mm)

.053"
(1.35mm)

.150"
(3.81mm)

.200"
(5.08mm)

.090"
(2.29mm)

.090"
(2.29mm)

Data Sheet: 2131

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

87

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Printed Circuit Board Fuseclips
5681 & 5682 Series
Fuseclips with Mounting Holes For ⁄Ω¢∑ Diameter Fuses
Dimensions (Inches)
Catalog
Number

End Clip
Stop Mat.**

5681-08
5681-15
5682-01
5682-02
5682-41
5682-44

No

Yes

Spg. Br.
Spg. Br.
BeCU
BeCU
Spg. Br.
Spg. Br.

Finish
Nickel
Bright Tin
Silver
Silver
Bright Tin
Bright Tin

B (To
C
End Stop) (Contact)
†
.106
.132
.106
.132

D
(Height)

E
Hole
(Width) Dia.

Fig.
Ref.

.265

.410

.320

.132

2

.260

.410

.320

.132

1

Data Sheet: 2132
B
C

5672 & 5674 Series
Fuseclips with Mounting Holes For ·Ω£™∑ Diameter Fuses
Dimensions (Inches)
Catalog
Number

End Clip
Stop Mat.**

5672-11

No

5674-01
5674-10

Yes

5674-41

Finish

Spg. Br.

Bright Tin

BeCU

Silver

BeCU

Albaloy

Spg. Br.

Bright Tin

B (To
C
End Stop) (Contact)

D
(Height)

E
Hole
(Width) Dia.

Fig.
Ref.

†

.362

.520

.380

.172

2

.168

.356

.520

.380

.172

1

D

E

FIGURE 1
Data Sheet: 2132

5956 & 5960 Series
Fuseclips with Mounting Holes For ⁄‹Ω£™∑ Diameter Fuses
Dimensions (Inches)
Catalog
Number

End Clip
Stop Mat.**

5956-16

No

Finish

B (To
C
End Stop) (Contact)

Spg. Br.

Bright Tin

BeCU

Silver

5960-09

BeCU

Silver

.200

.172

5960-23

BeCU

Albaloy

.168

.196

Yes

.312

.710

E
Hole
(Width) Dia.

5960-07

5960-51

†

D
(Height)

.470

.168

.172

Fig.
Ref.
2

.196

Spg. Br. Bright Dip*

.168

5960-53

Spg. Br. Bright Dip*

.200

.389

.710

.470

.172

.196

5960-61

Spg. Br. Bright Tin

.168

.196

5960-62

Spg. Br. Bright Tin

.168

.132

5960-63

Spg. Br. Bright Tin

.200

.172

5960-64

Spg. Br. Bright Tin

.200

.128

1

C

Data Sheet: 2132

5591 & 5592 Series
Fuseclips with Mounting Holes For ·Ω¡§∑ Diameter Fuses
D

Dimensions (Inches)
Catalog
Number

End Clip
Stop Mat.**

5591-42
5592-01
5592-11
5592-33

Yes
No

Spg. Br.
BeCU
Spg. Br.
Spg. Br.

Finish
Bright Dip*
Silver
Silver
Bright Dip*

B (To
C
End Stop) (Contact)

D
(Height)

E
Hole
(Width) Dia.

.260

.510

.890

.600

†

.505

.890

.600

.172
.200
.200
.172

Fig.
Ref.
1
2

E

FIGURE 2

* Bright Dip is actually treated bare metal with no plating.
** Spg. Br. — Spring Bronze; BeCU — Beryllium Copper.
† Hole in center of both clip and contact area.

1A1837 For ⁄‹Ω¡§∑ Diameter Fuses
Data Sheet: 2132

88

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Rail Mount Terminal Blocks
Series NDN
35mm DIN Rail Compatible
High Density Design: Up to 48 circuits per foot
Clamping Collar: Secures wires
Large, Captive, Wire-ready Screws: Speeds assembly
Snap-on Installation to DIN Rail: Fast, easy assembly
Fully Shielded Construction: 600V spacings
Unique One-piece Construction: Increases reliability
Thermoplastic Moldings: Strong and impact resistant
Material: UL Recognized 94V-2 thermoplastic
Collars: Heat treated stainless steel
Terminals: Tin plated copper alloy
Screws: Zinc plated steel
Agency Information: UL E62622; CSA LR15364

NDNV4-__ __(color)

NDN3-__ __(color)

NDN63-__ __(color)

Ratings: NDNV4 30A, 600V; UL/CSA
Center Spacing: .250∑ (6.35)
Number of Poles: 4
Circuits per Foot: 48
Circuit Jumper: JN4, 4 circuits
Wire Size: AWG #10-22 CU
Screw Size: #6-32
Mounting Options: 35mm DIN rail,
C-rail
Marking Tape: MTC6
Torque Rating: 18 in/lb max.
NDNV4 Colors: YE - Yellow
WH - White

Ratings: 30A - field wiring;
40A - factory wiring 600V; UL/CSA
Center Spacing: .300∑ (7.62)
Number of Poles: 3
Circuits per Foot: 38
Circuit Jumper: JNDN3, 2 circuits
Wire Size: AWG #10-22 CU
Screw Size: #6-32
Mounting Options: 35mm DIN rail,
C-rail
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
NDN3 Colors: YE - Yellow
WH - White

Ratings: 65A, 600V; UL/CSA
Center Spacing: .375∑ (9.52)
Number of Poles: 3
Circuits per Foot: 30
Circuit Jumper: JN3, 2 circuits
Wire Size: AWG #6-18 CU
Screw Size: #10-32
Mounting Options: 35mm DIN rail,
C-rail
Marking Tape: MT12-⁄Ω™
Torque Rating: 35 in/lb max.
NDN63 Colors: YE - Yellow
WH - White

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

89

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Rail Mount Terminal Blocks

NDN1-WH
Ratings: 90A, 600V
Center Spacing: .635∑ (16.13)
Number of Poles: 1
Circuits per Foot: 18
Circuit Jumper: JN1, 2 circuits
Wire Size: AWG #2-18 CU
Screw Size: ⁄Ω¢-28
Mounting Options: 35mm DIN rail,
C-rail (Dove-tail option is available for
mounting side-by-side. Order part no.
NDN1A-WH.)
Marking Tape: MT12-⁄Ω™
Torque Rating: 32 in/lb max.
NDN1Colors: WH -White

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

NDN111-__ __(color)
Ratings: 90A, 600V; UL/CSA
Center Spacing: .635∑ (16.13)
Number of Poles: 3
Circuits per Foot: 18
Circuit Jumper: JN1, 2 circuits
Wire Size: AWG #2-18 CU
Screw Size: ⁄Ω¢-28
Mounting Options: 35mm DIN rail,
C-rail, Base Mount. (Dove tail option is
available for mounting side-by-side.
Order part no. NDN111A-WH.)

Marking Tape: MT12-⁄Ω™
Torque Rating: 32 in/lb max.
NDN111
NDN111A
Colors:
Colors:
YE - Yellow
YE - Yellow
WH - White
WH- White

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Series NDN Terminal Block Accessories

NDNA

NDNAS

35mm DIN rail
35mm DIN rail
Aluminum
End Stop
NDNA 100 1 meter
NDNA 200 2 meters

90

NFTA

NRA37-1/2

SOA72

C-rail
Aluminum
NFTA36
36” long
NFTA72
72” long

C-rail
Low profile
No flange
Aluminum
37⁄Ω™∑ length

72” long
Stand-Off Channel
for C-rail

MARKING JUMPERS
TAPE
See series
See series
specifications

specifications

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Rail Mount Terminal Blocks

N512-BK

NFT2-__ __(color)

NFT3-__ __(color)

Ratings: 5A, 600V; UL/CSA
20A, 300V; UL/CSA
Center Spacing: .197∑ (5.00)
Number of Poles: 12
Circuits per Foot: 60
Circuit Jumper: JN512, 12 circuits
Wire Size: AWG #12-22 CU
Screw Size: #4-48
Mounting Options: C-rail, 15mm
DIN rail
Marking Tape: AT512
Torque Rating: 12 in/lb max.
Color: Black-BK

Ratings: 40A, 600V; UL/CSA; 55A
factory wired.
Center Spacing: .281∑ (7.13)
Number of Poles: 2
Circuits per Foot: 38
Circuit Jumper: JN2, 2 circuits
Wire Size: AWG #8-22 CU
Screw Size: #8-32
Mounting Options: C-rail
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
NFT2 Colors: WH - White

Ratings: 40A, 600V; UL/CSA; 55A
factory wired.
Center Spacing: .390∑ (9.91)
Number of Poles: 3
Circuits per Foot: 28
Circuit Jumper: JN3, 2 circuits
Wire Size: AWG #8-22 CU
Screw Size: #8-32
Mounting Options: C-rail
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
NFT3 Colors:
YE - Yellow WH - White

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

NC3-WH

NSE3-WH

NSS3-WH

Ratings: 175A, 600V; UL/CSA
Center Spacing: 1.06∑ (26.92)
Number of Poles: 3
Circuits per Foot: 11
Wire Size: 2/0-#14 CU/AL
Screw Size: fiΩ¡§-24
Mounting Options: C-rail,
Base Mount
Marking Tape: MT12-⁄Ω™
Torque Rating: 45 in/lb max.
NC3 Colors: WH - White

Ratings: 115A, 600V; UL/CSA
Center Spacing: 1.06∑ (26.92)
Number of Poles: 3
Circuits per Foot: 11
Wire Size: For use with wire crimped
to ring terminal.
Screw Size: ⁄Ω¢-28
Mounting Options: C-rail,
Base Mount
Marking Tape: MT12-⁄Ω™

Ratings: 30A, 600V; UL/CSA
Center Spacing: .385∑ (9.77)
Number of Poles: 3
Circuits per Foot: 28
Circuit Jumper: JNSS3, 2 circuits
Wire Size: For use with wire crimped
to ring terminal.
Screw Size: #6-32
Mounting Options: C-rail
Marking Tape: MT12-⁄Ω™
NSS3 Colors: WH - White

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

91

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Sectional Terminal Blocks

PSU1-WH
PLU3-_ _(color)

PLU1-WH

Depluggable Rail Mount
Ratings: 40A, 600V; UL/CSA
Center Spacing: .390∑ (9.91)
Number of Poles: 3
Circuits per Foot: 28
Circuit Jumper: JN3, 2 circuits
Wire Size: AWG #8-22 CU
Screw Size: #8-32
Mounting Options: C-rail, Stackable
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
PLU3 Colors: YE - Yellow
WH - White

Depluggable Rail Mount
Ratings: 70A, 600V; UL/CSA
Center Spacing: .625∑ (15.88)
Number of Poles: PLU1-WH (1 pole);
PLU11-WH (2 poles); PLU111-WH (3 poles)
Circuits per Foot: 19
Circuit Jumper: JN1, 2 circuits
Wire Size: AWG #4-18 CU
Screw Size: ⁄Ω¢-28
Mounting Options: C-rail, Stackable
Marking Tape: MT12-⁄Ω™
Torque Rating: 32 in/lb max.
PLU1
PLU11
PLU111
Colors:
Colors:
Colors:
WH- White
WH -White WH- White

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

Depluggable Rail Mount
Ratings: 45A*, 600V; UL/CSA
(*45A rating achieved with ring
terminal crimped to wire)
Center Spacing: .625∑ (15.88)
Number of Poles: PSU1-WH (1 pole);
PSU11-WH (2 poles); PSU111-WH (3 poles)
Circuits per Foot: 19
Wire Size: For use with crimp on
connectors only.
Screw Size: #10-32
Mounting Options: C-rail, Stackable
Marking Tape: MT12-⁄Ω™
Torque Rating: 32 in/lb max.
PSU1
PSU11
PSU111
Colors:
Colors:
Colors:
WH- White
WH -White WH- White
CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

PLK3-_ _(color)
KT3-WH

KT4-WH

Base Mount
Ratings: 40A, 600V; UL/CSA
Center Spacing: .390∑ (9.91)
Number of Poles: 3
Circuits per Foot: 28
Circuit Jumper: JN3, 2 circuits
Wire Size: #8-22 CU
Screw Size: #8-32
Mounting Options: Base Mount,
Stackable. KAD end mount adapter
optional.
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
KT3 Colors: WH - White

Base Mount
Ratings: 30A, 600V; UL/CSA
Center Spacing: .250∑ (6.35)
Number of Poles: 4
Circuits per Foot: 48
Circuit Jumper: JN4, 4 circuits
Wire Size: AWG #10-22 CU
Screw Size: #6-32
Mounting Options: Base Mount.
Mounting screws recommended every
12 circuits.
Marking Tape: MTC6
Torque Rating: 18 in/lb max.
KT4 Colors: WH - White

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

92

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

Base Mount
Ratings: 40A, 600V; UL
Center Spacing: .390∑ (9.91)
Number of Poles: 3
Circuits per Foot: 28
Circuit Jumper: JN3, 2 circuits
Wire Size: AWG #8-22 CU
Screw Size: #8-32
Mounting Options: Base Mount,
Stackable. End Piece (Part No. KAD) is
required for mounting. Mounting
screws recommended every 15 circuits.
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
PLK3 Colors: YE - Yellow
WH - White
CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Quick Connect Terminal Blocks

NTQ23-WH

BNQ21-WH

BQQ41-WH

Ratings: 40A, 600V
Center Spacing: .390∑ (9.91)
Number of Poles: 3
Circuits per Foot: 28
Wire Size: AWG #8-22 CU
Screw Size: #8-32
Mounting Options: C-rail
Marking Tape: MT12-⁄Ω™
Color: White-WH
Torque Rating: 18 in/lb max.

Ratings: 40A, 600V; UL/CSA
Center Spacing: .437∑ (11.10)
Number of Poles: 1
Circuits per Foot: 24
Wire Size: AWG #8-22 CU
Screw Size: #8-32
Quick Connects: .250∑ ≈ .031∑
Mounting Options: Base Mount,
Stackable. End Piece (Part No. BQE)
is required for mounting. Mounting
screws recommended every 8 circuits.
Torque Rating: 18 in/lb max.

Ratings: 30A, 600V; UL/CSA
Center Spacing: .437∑ (11.10)
Number of Poles: 1
Circuits per Foot: 24
Wire Size: For use with quick
connect terminals only.
Quick Connects: .250∑ ≈ .031∑
Mounting Options: Base Mount,
Stackable. End Piece (Part No. BQE)
is required for mounting. Mounting
screws recommended every 8 circuits.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

93

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Rail Mount Fuseholders and Circuit Breakers

NDNF1-WH

NDNLFD1

Ratings: 30A, 600V; UL/CSA
Number of Poles: 1
Fuse Size: ⁄‹Ω£™∑ ≈ 1⁄Ω™∑
(KTK, FNQ).
Circuit Jumper: JF1, 2 circuits
Wire Size: AWG #8-22 CU
Mounting Options: 35mm DIN rail,
C-rail
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
NDNF1 Colors: WH - White
Fuse Pullers (Optional):
PF1
Lighted neon or incandescent –
LPF-(Voltage rating)
LPF1-24
LPF1-120
LPF1-120-C
LPF1-220
LPF1-440

Ratings:
NDND1: 30A, 600V; UL/CSA (non-fused)
NDNFD1: 15A, 600V/CSA (fused)
NDNLFD1*: 15A, 600V (fused)
Number of Poles: 1
Fuse Size: ⁄Ω¢∑ ≈ 1⁄Ω¢∑
(Buss® AGC, MDL or equivalent.)
Circuit Jumper: JF1, 2 circuits
Wire Size: AWG #8-22 CU
Mounting Options: 35mm DIN rail,
C-rail
Marking Tape: MT12-⁄Ω™
Torque Rating: 18 in/lb max.
Extension: WH - White
*WH24 - 24V White
(Only available with NDNLFD1)

94

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Fuseblocks, Holders and Terminal Blocks

Bussmann®

Power Distribution Blocks

Series 11675

Series 11725

Quick-Connect Power
Distribution Block

Quick-Connect Power
Distribution Block

Ratings: 40A, 250V; UL/CSA
Poles: 2 to 6 poles with (3) .250∑ quick-connect terminals
per pole.
Input Wire Sizes: #8 – #14 CU
Torque Rating: 9 in/lb max.
Design: For equipment that requires
screw connections in the field. Reduces assembly costs of
internal wiring.
Agency Information: UL E62622; CSA LR15364

Ratings: 70A, 600V; UL/CSA
Poles: 2, 3 or 4 poles with (4) .250∑ quick-connect terminals
per pole.
Input Wire Sizes: #2 – #14 CU/#8 AL
Torque Rating: 45 in/lb max.
Design: For equipment that requires screw connections in
the field. Reduces assembly costs of internal wiring.
Agency Information: UL E62622; CSA LR15364

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Series 14002
Barrier Terminal Block
Ratings: 115A, 600V; UL/CSA
Poles: 2 to 6 poles
Wire Sizes: #2 – #14 CU/#8 AL
Marking: Marking strip optional, consult factory.
Options For Load Side Connector:
CP: Sems pressure plate, rated 60A, 600V
Q: Quick-Connect, rated 50A, 600V
To order options, enter letter code in front of
Part No.: ie; CP14002-2.
Agency Information: UL E62622; CSA LR15364

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

Series 14004
Dead Front Terminal Block
Ratings: 90A, 600V; UL/CSA
Poles: 2 to 12 poles
Wire Sizes: #4 – #14 CU/#8 AL
Marking: Marking strip optional, consult factory.
Agency Information: UL E62622; CSA LR15364
CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering
at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

95

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Power Distribution & Terminal Blocks

Series 162, 163, 165
Series 160, 162, 163 & 165
Ratings: To 840A, 600V; UL Recognized/CSA. See Table.
Materials: Molded material: Black, UL rated 94V-0
thermoplastic.
Agency Information: UL E62622 General Industrial Class
per UL 1059; CSA LR15364.
Power Distribution Blocks (600V) Catalog Data
Part
Number
*16021
*16023
16220
16321
16323
16325
16330

Line
Connection
2/0-#14CU, 2/0-#8AL
350kcmil-#6CU-AL
2/0-#14CU, 2/0-#8AL
2/0-#14CU, 2/0-#8AL
350kcmil-#6CU-AL
(2)2/0-#14CU, 2/0-#8AL
500kcmil-#6CU-AL

16332

350kcmil-#6CU-AL

16335

500kcmil-#6CU-AL

16370

350kcmil-#6CU-AL

16371

350kcmil-#6CU-AL

16372

350kcmil-#6CU-AL

16373

350kcmil-#6CU-AL

16375

600kcmil-#2CU-AL

16376

600kcmil-#2CU-AL

16377

(2)300kcmil-#4CU-AL

16528

(2)

16530
16541

(2)500kcmil-#6CU-AL

600kcmil-#2CU-AL

500kcmil-#6CU-AL

Connector
Load
Material &
Connection
Ampacity
(6)#4-#14CU, #4-#8AL
AL-175A
6)#4-#14CU, #4-#12AL
AL-310A
(4)#4-#14CU, #4-#8AL
AL-175A
(6)#4-#14CU, #4-#8AL
AL-175A
(6)#4-#14CU, #4-#12AL
AL-310A
(6)#4-#14CU, #4-#8AL
AL-350A
(6)#2-#14CU, #2-#12AL
AL-380A
(3)#2-#14CU, #2-#8AL
AL-310A
(2)1/0-#14CU, 1/0-#8AL
(3)#2-#14CU, #2-#8AL
AL-380A
(2)1/0-#14CU, 1/0-#8AL
(12)#4-#14CU, #4-#12AL
AL-310A
(6)#2-#14CU, #2-#8AL
AL-310A
(3)1/0-#14CU, 1/0-#8AL
(21)#10-#14CU, #10AL
AL-310A
(3)1/0-#14CU-AL
AL-310A
(14)#10-#14CU, #10AL
(12)#4-#14CU, #4-#12AL
AL-420A
(6)#2-#14CU, #2-#8AL
AL-420A
(3)1/0-#14CU, 1/0-#8AL
(12)#4-#14CU, #4-#12AL
AL-570A
(4)3/0-#6CU-AL
AL-840A
(4)#4-#14CU-AL
(12)#4-#14CU-AL
AL-760A
(21)#6-#14CU-AL
AL-380A

Agency
Information
UL
CSA
UL
CSA
UL
CSA
UL
CSA
UL
CSA
UL
CSA
UL
CSA
UL

CSA

UL
UL

CSA
—
CSA

UL

CSA

UL

CSA

UL

CSA

UL

CSA

UL

CSA

UL

—

UL

CSA

UL
UL

CSA
—

*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)
have mounting holes within barriers. See Data Sheet for dimensional drawings.

How To Order: Catalog Number + # of Poles
Example: 16020 – 3 (complete part number)
Optional covers:

160 Series: CPB160 - (pole)
162 Series: CPB162 - (pole)
163 Series: CPDB- (pole)
165 Series: CPDB165 (1 for each pole)

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1117 (Series 160, 162, 165); 1148 (Series 163)

96

Ratings: To 760A, 600V; UL Recognized/CSA. See Table.
Materials: Molded material: Black, UL rated 94V-0 thermoplastic.
Agency Information: UL E62622 General Industrial Class
per UL 1059; CSA LR15364.
Connector–Stud Blocks (600V) Catalog Data
Part
Line
Number
Connection
Connector to Stud
16280
2/0-#14CU-AL
16281
2/0-#14CU-AL
16378
500kcmil-#6CU-AL
16383
500kcmil-#6CU-AL
(2)500kcmil-#6CU-AL
16582
Stud to Stud
16290 ⁄Ω¢-20 ≈ ‹Ω¢ Stud
16390
‹Ω•-16 ≈ 1⁄Ω• Stud
16394
⁄Ω™-13 ≈ 1⁄Ω¡§ Stud
16395
‹Ω•-16 ≈ 1‡Ω¡§ Stud
16591
‹Ω•-16 ≈ 1‡Ω¡§ Stud
16593
⁄Ω™-13 ≈ 1 Stud

Load
Connection

Connector
Material &
Ampacity

⁄Ω¢-20 ≈ ‹Ω¢ Stud
⁄Ω¢-20 Tapped hole
(2)⁄Ω¢-20 ≈ 1 Stud
(1)‹Ω•-16 ≈ 1 Stud
(2)‹Ω•-16 ≈ 1fiΩ• Stud

AL-175A
AL-175A
AL-380A
AL-380A
AL-760A

UL
UL
UL
UL
UL

CSA
CSA
CSA
CSA
CSA

⁄Ω¢-20 ≈ ‹Ω¢ Stud
‹Ω•-16 ≈ 1⁄Ω• Stud
⁄Ω™-13 ≈ 1⁄Ω¡§ Stud
(2)⁄Ω¢-20 ≈ ·Ω¡§ Stud
(2)‹Ω•-16 ≈ 1‡Ω¡§ Stud
⁄Ω™-13 ≈ 1 Stud

CU-175A
CU-250A
CU-400A
CU-310A
CU-400A
CU-600A

UL
UL
UL
UL
UL
UL

—
CSA
CSA
CSA
—
CSA

Agency
Information

Series 160, 162, 163 and 165
Ratings: To 620A, 600V; UL Recognized/CSA. See Table.
Materials: Molded material: Black, UL rated 94V-0 thermoplastic.
Agency Information: UL E62622 General Industrial Class
per UL 1059; CSA LR15364.

Power Distribution Blocks (600V) Catalog Data
Connector
Part
Line
Load
Material &
Agency
Number
Connection
Connection
Ampacity
Information
*16000
2/0-#8CU-AL
2/0-#8CU-AL
AL-175A
UL
—
*16003
250kcmil-#6CU Only
250kcmil-#6CU Only
CU-255A
UL
—
*16005
350kcmil-#6CU-AL
350kcmil-#6CU-AL
AL-310A
UL
—
16200
#2-#14CU, #2-#8AL
#2-#14CU, #2-#8AL
AL-115A
UL
CSA
16201
1/0-#14CU Only
1/0-#14CU Only
CU-150A
UL
CSA
16204
2/0-#8CU-AL
2/0-#8CU-AL
AL-175A
UL
CSA
16301
250kcmil-#6CU Only
250kcmil-#6CU Only
CU-255A
UL
CSA
16303
350kcmil-#6CU-AL
350kcmil-#6CU-AL
AL-310A
UL
CSA
16306
500kcmil-#6CU-AL
500kcmil-#6CU-AL
AL-380A
UL
CSA
(2)350kcmil-#4CU-AL
(2)350kcmil-#4CU-AL
16500
AL-620A
UL
CSA
(2)500kcmil-#6CU-AL
(2)500kcmil-#6CU-AL
16504
AL-760A
UL
CSA
*160 Series Bases have mounting holes outside the barriers. Other bases (162 through 165)
have mounting holes within barriers. See Data Sheet for dimensional drawings.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1117 (Series 160, 162, 165)

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuseblocks, Holders and Terminal Blocks

Power Distribution Blocks
Input/Output Termination Options
Wire Size

Basic
Part No.

163 Series
(Replaces Bussmann 164 Series)
Ampere Ratings: up to 420A
Voltage Ratings: 600V
Construction: UL 94VO. Tin-plated aluminum connectors.
Agency Information:
UL Recognized: UL E62622
General Industrial Class per UL1059
CSA Certified: CSA LR15364

Optional Covers:

4.14"

Supplied with (4) #4 thread-cutting
screws assembled as shown

Line Side

Load Side

Amps/
Pole

16301*

250kcmil-#6CU Only

250kcmil-#6CU Only

255

16303

350kcmil-#6CU-AL

350kcmil-#6CU-AL

310

16306

500kcmil-#6CU-AL

500kcmil-#6CU-AL

16321

2/0-#14CU, 2/0-#8AL

(6)#

16323

350kcmil-#6CU-AL

(6)

16325

2/0-#14CU, 2/0-#8AL

(6)#

16330

500kcmil-#6CU-AL

(6)

16332

350kcmil-#6CU-AL

(3) #2-#14CU, #2-#8AL
(2) 1/0-#14CU, 1/0-#8AL 310

16335

500kcmil-#6CU-AL

(3) #2-#14CU, #2-#8AL
(2) 1/0-#14CU, 1/0-#8AL 380

16370

350kcmil-#6CU-AL

(12)

16371

350kcmil-#6CU-AL

(6) #2-#14CU, #2-#8AL
(3) 1/0-#14CU, 1/0-#8AL 310

16372

350kcmil-#6CU-AL

(21) #10-#14CU, #10AL 310

16373

350kcmil-#6CU-AL

(14) #10-#14CU, #10AL
(3) 1/0-#14CU-AL
310

16375

600kcmil-#2CU-AL

(12)

16376

600kcmil-#2CU-AL

(6) #2-#14CU, #2-#8AL
(3) 1/0-#14CU, 1/0-#8AL 420

16377

(2)

16378

500kcmil-#6CU-AL

Stud Size
(2) ⁄Ω¢-20 x 1

380

16383

500kcmil-#6CU-AL

Stud Size
(1) ‹Ω•-16 x 1

380

300kcmil-#4CU-AL

380

4-#14CU, #4-#8AL

175

#4-#14CU, #4-#12AL

310

4-#14CU, #4-#8AL

350

#2-#14CU, #2-#12AL

380

#4-#14CU, #4-#12AL

#4-#14CU, #4-#12AL

4-#14CU, #4-#12AL

(12)

310

420

570

16390

Stud Size
‹Ω•-16 x 1⁄Ω•

Stud Size
‹Ω•-16 x 1⁄Ω•

250

16394

Stud Size
⁄Ω™-13 x 1⁄Ω¡§

Stud Size
⁄Ω™-13 x 1⁄Ω¡§

400

16395

Stud Size
‹Ω•-16 x 1‡Ω¡§

Stud Size
(2) ⁄Ω¢-20 x ·Ω¡§

310

Textured surface for marking

Line/Load

*Copper connectors for use with copper wire only.
CPDB-1 (single pole) 2.10"
CPDB-2 (two pole)
3.72"
CPDB-3 (three pole) 5.34"
Covers ordered and shipped separately.

1-pole
1.96"

2-pole
3.58"

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

3-pole
5.20"

Ordering Information:
163 Series blocks are available in 1, 2 or 3 poles.
To order: Basic Part No. + Number of poles
Examples:
16301-1 = (one-pole block)
16303-3 = (three-pole block)

.31"

3.37"

4.00"

.97"

1.62"
3.25"
Mtg. hole .21 x .41,
c'bore .42 x .62 x .12 deep

3.32"

Data Sheet: 1148
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

97

Page 98
Blank
(Do NOT Print)

Bussmann®

Overview

for Fusible Disconnect Switches

CFD30J3
Catalog number

CFD60J3
3 pole

General purpose
amp rating

FD200J3

FD400J3

FD600J3

FD800L3

CFD30CC3

CFD30J3

CFD60J3

CFD100J3

FD200J3

FD400J3

FD600J3

FD800L3

30

30

60

100

200

400

600

800

N/A
UL98 & IEC
UL98 & IEC

N/A
UL98 & IEC
UL98 & IEC

N/A
UL98 & IEC
UL98 & IEC

UL98 & IEC
UL98 & IEC
UL98 & IEC

UL98 & IEC
UL98 & IEC
UL98 & IEC

UL98 & IEC
UL98 & IEC
UL98 & IEC

UL98 & IEC
UL98 & IEC
UL98 & IEC

UL98 & IEC
UL98 & IEC
UL98 & IEC

600

600

600

600

600

600

600

600

HP
HP
HP
HP

5/7.5
7.5
15
20

5/7.5
7.5
15
20

15
15
30
50

25
30
60
75

50
60
125
150

100/125
125
250
350

150
200
400
500

200
250
500
600

HP
HP

2
3

2
3

—
—

—
—

—
—

—
—

—
—

—
—

CC

J

J

J

J,T

J,T

J,T

L

1000

1000

750

750

1000

1000

1000

1000

A

Approvals1

CFD100J3

CFD30CC3 – FD800L3

2 pole
3 pole
4 pole

Technical ratings
(UL,CSA)
Max operating voltage

V

Max horsepower rating
Three phase
200 – 208V
240V
480V
600V
Single phase
120V
240V
UL fuse class
Technical ratings
(IEC)
Rated insulation and operational
voltage. ac20 and dc202
Rated thermal current, Ith
ac 20/dc 20
ac 20/dc 20

open
enclosed

A
A

32
32

32
32

63
63

125
125

250
250

400
400

630
600

800
720

ac 21A

≤500V
≤690V

A
A

32
32

32
32

63
63

125
125

250
250

400
400

630
630

800
800

14/15
25

14/15
25

30
60

80/90
132

132/140
230

210/230
330

315/340
540

350/380
600

lb
lb

1.54
1.98

1.54
1.98

2.86
3.52

3.30
3.96

15.21
17.4

17.2
19.4

37.48
46.3

37.48
46.3

H in
W in
D in

3.82
4.17
4.21

3.82
4.17
4.21

3.94
5.63
5.04

5.66
7.06
5.09

7.87
10.31
7.83

7.87
11.22
8.11

11.42
14.69
9.21

11.42
14.69
9.21

Rated operational power ac23
400/415V
690V

kW
kW

Physical characteristics
Weight
Dimension

3 pole switch
4 pole
3 pole

Accessories
Double break contacts

S

S

S

S

S

S

S

S

Fuse cover

S

S

S

•

S

S

S

S

Terminal lug kit

Integral

Integral

Integral

BDTL24

BDTL25

BDTL26

BDTL27

BDTL27

Terminal shroud

Not required

Not required

Not required

•

•

•

•

•

Auxiliary contact

•

•

•

•

•

•

•

•

Handle UL/NEMA type
Type 1, 3R, 12
Type 1, 3R, 4, 4X, 12

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

Conversion kit
6 pole
Transfer
Bypass
Mechanical interlock

•
•
—
•

•
•
—
•

•
•
—
—

•
•
—
—

•
•
•
•

•
•
•
•

•
•
•
•

•
•
•
•

Electrical interlock

—

—

—

—

•

•

•

•

S = Standard
• = Available
— = Not available
1 UL listed switches are also CSA approved.
2 1000V IEC 408

UL listed, CSA approved, IEC rated, CE marked

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

99

30A Fusible Disconnect Switches

Bussmann®

Base & DIN Rail Mounted UL Fuse Class J, CC
For a complete assembly,
please select one of each:
1 switch
1 handle
1 shaft
CFD30J3

+

CDS180S

+

CDH3S

30A Switches, 600V
UL
General
Purpose
Amp Rating

CFD30J3

3 pole
30
30
4 pole
30
30

IEC
Fuse
Type
600V

200V

J
CC

5
5

7.5
7.5

7.5
7.5

15
15

20
20

#18 – 8
#18 – 8

CU CFD30J3
CU CFD30CC3

J
CC

5
5

7.5
7.5

7.5
7.5

15
15

20
20

#18 – 8
#18 – 8

CU CFD30J4
CU CFD30CC4

Selector Handles
CDH3S, 5S

NEMA
Type

IEC
Type

Maximum Horsepower Rating
Three Phase
208V
240V
480V
600V

— For use with shafts

Color

All marked both O/I & Off/On
1,3R,12
IP65
Black
1,3R,12
IP65
Red/Yellow
1,3R,12
IP65
Black
1,3R,12
IP65
Red/Yellow

Terminal Lugs
Wire
Wire
Size
Type

.20 x .20" (

Catalog
Number

5 x 5 mm)

Defeatable

Padlockable

Weight
(lbs)

Catalog
Number

—
—
Yes
Yes

Yes
Yes
Yes
Yes

0.16
0.16
0.16
0.16

CDH3S
CDH4S
CDH5S
CDH6S

.20 x .20" (

5 x 5 mm)

CDH4S, 6S

Shafts

— For use with CDH selector handles

Shaft Length
(inches/mm)

CDS_ _S

3.3/85
4.1/105
4.7/120
5.1/130
7.1/180
9.8/250
13.0/330

Mounting Depth1
(in inches)

5.5
5.5
5.5
5.5
6.3
9.1
12.2

– 5.7
– 6.5
– 7.1
– 7.5
– 9.4
– 12.2
– 15.4

Weight
(lbs.)

Catalog
Number

0.04
0.04
0.05
0.05
0.08
0.10
0.14

CDS85S
CDS105S
CDS120S
CDS130S
CDS180S
CDS250S
CDS330S

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006

100

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Handles & Shafts

For 30A Fusible Disconnect Switches
For a complete assembly,
please select one of each:
1 switch
1 handle
1 shaft
CFD30J3

+

CDS67P

+

BDH106

Pistol Handles
For use with shafts
NEMA
Type

IEC
Type

1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,12
1,3R,12

IP65
IP65
IP65
IP65
IP65
IP65
IP65
IP65

.20 x .20" (

BDH104, 106

5 x 5 mm)

Color

Marking

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow

BDH105, 107

Length
(inches/mm)

Defeatable

Padlockable

Weight
(lbs.)

Catalog
Number

1.8/45
1.8/45
2.6/65
2.6/65
2.6/65
2.6/65
2.6/65
2.6/65

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

0.28
0.28
0.29
0.29
0.29
0.29
0.29
0.29

BDH104
BDH105
BDH106
BDH107
CDHXB65
CDHXY65
BDH106T
BDH107T

O/I&Off/On
O/I&Off/On
O/I&Off/On
O/I&Off/On
O/I&Off/On
O/I&Off/On
Off/On/Test
Off/On/Test

Shafts
For use with pistol handles
Shaft length
(inches/mm)

Mounting Depth
(in inches)

5.9/150
6.7/170
10.4/265
15.8/400
19.7/500

CDS__ __P

.20 x .20" (

4.9
5.9
9.5
15.0
20.5

–
–
–
–
–

8.9
9.7
13.4
18.7
22.6

5 x 5 mm)
Weight
(lbs.)

Catalog
Number

0.07
0.08
0.12
0.18
0.23

CDS48P
CDS67P
CDS49P
CDS50P
CDS99P

5.20"
132mm
BDH79
BDH79 Mounted

5.20"/132mm
BDH79 Mounted Depth

Direct Mount Handle
Mounts directly to switch, no shaft necessary
NEMA
Type

Color

Marking

Length
(Inches/mm)

1

Black

O/I/Test

50

Padlockable

Yes

Weight
(lbs.)

Catalog
Number

0.10

BDH79

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

101

60A - 100A

Bussmann®

For Fusible Disconnect Switches UL Fuse Class J
For a complete assembly,
please select one of each:
1 switch
1 handle
1 shaft
1 terminal lug kit
CFD60J3

60

—

+

BDS210

+

BDH58

100A Switches, 600V

UL General
Purpose
Amp Rating

UL Fuse
Type
600V

3 pole
60
100
4 pole
60
100

Maximum Horsepower Rating
Three Phase
200V
208V
240V
480V

J
J

15
25

15
25

15
30

30
60

50
75

J
J

15
25

15
25

15
30

30
60

50
75

Pistol Handles —
NEMA/UL
Type

1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,4,4X,12
1,3R,4,4X,12

.24 x .24" (

Catalog
Number

600V

3 pole
CFD60J3
CFD100J3
4 pole
CFD60J4
CFD100J4

6 x 6 mm)

IEC
Type

Color

Length
(inches/mm)

IP65
IP65
IP65
IP65
IP65
IP65

Black
Red/Yel
Black
Red/Yel
Black
Red/Yel

2.6/65
2.6/65
3.1/80
3.1/80
3.1/80
3.1/80

Shafts

BDH58, 60
Marking

O/I
O/I
O/I
O/I
O/I
O/I

—

&
&
&
&
&
&

.24 x .24" (

BDH59, 61
Padlockable

Weight
(lbs.)

Catalog
Number

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

0.29
0.29
0.30
0.30
0.30
0.30

BDH58
BDH59
BDH60
BDH61
CDHXB86
CDHXY86

6 x 6 mm)

Mounting Depth
(in inches)

5.9/150
8.3/210
11.4/290
14.2/360
16.9/430

5.5
8.0
11.0
13.8
16.5

CFD100J3

Defeatable

Off/On
Off/On
Off/On
Off/On
Off/On
Off/On

Shaft Length
(inches/mm)

BDS__

CFD60J3

–
–
–
–
–

8.5
11.0
14.0
16.8
19.7

Weight
(lbs.)

Catalog
Number

0.09
0.13
0.18
0.23
0.27

BDS150
BDS210
BDS290
BDS360
BDS430

Twisted Shafts
Rotates handle 45°

.24 x .24" (

Shaft Length
(inches/mm)

Mounting Depth
(in inches)

5.1/130
8.3/210
11.4/290
14.2/360

BDST__

4.8
8.0
11.0
13.8

–
–
–
–

6 x 6 mm)

7.8
11.0
14.0
16.8

Weight
(lbs.)

Catalog
Number

0.08
0.13
0.18
0.23

BDST4
BDST25
BDST29
BDST30

Direct Mount Handle
Mounts directly to switch, no shaft necessary
NEMA
Type

Color

Marking

Length
(Inches/mm)

1

Black

O/I/Test

50

Padlockable

Yes

Weight
(lbs.)

Catalog
Number

0.10

CDH4

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006

102

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Accessories

For 60A - 100A Fusible Disconnect Switches
Terminal Lug Kit

BDTL24

For Use On:

Wire Size

Kit Weight
(lbs.)

CFD60J_
CFD100J_

#14 – 4
#14 – 2/0

—
0.43

Wire
Type

CU
CU/AL

Terminal
Lugs Per Kit

Catalog
Number

—
6

Integral
BDTL24

Auxiliary Contacts

CDAUX10 CDAUX01K

Description

For Use On:

Weight
(lbs.)

AC Thermal
Amp Rating

AC Rated
Voltage

Catalog
Number

1 N.O.
1 N.C.

CFD60 – CFD100

0.07
0.07

10
10

600
600

CDAUX10
CDAUX01K

Replacement Fuse Clip
Description

Catalog
Number

For Use On:

Removable fuse carrier

CFD60

CFC60J

CFC60J

Replacement Fuse Covers
Description

Catalog
Number

For Use On:

Transparent fuse cover

CFD100

CFCVR100

CFCVR100

Terminal Shroud
Description

Includes one
terminal shroud
for line or load side

For Use On:

Weight
(lbs.)

Catalog
Number

CFD100, 1-POLE

0.04

CFTS100

CFTS100

Terminal Poles

CFZ1

Description

For Use On:

Weight
(lbs.)

AC Thermal
Amp Rating

AC Rated
Voltage

Catalog
Number

Detachable neutral
mounts on side
of switch or DIN rail

CFD60

0.13

63

600

CFZ1

CFD100

0.31

125

600

CFZ2

DIN Rail

NDNA100

Description

For Use On:

WeIght
(lbs.)

Length
(inches/mm)

Catalog
Number

35mm Aluminum DIN Rail
35mm Aluminum DIN Rail

CFD60
CFD60

.38
.75

39.4/1000
78.8/1000

NDNA100
NDNA200

“T” Type Fuse Adapter Kit

BDTA1

Description

For Use On:

Catalog
Number

100A, 600V

CFD100

BDTA1

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

103

200A - 800A

Bussmann®

Fusible Disconnect Switches UL Fuse Class J, T, L
For a complete assembly,
please select one of each:
1 switch
1 handle
1 shaft
1 terminal lug kit
FD200J3

+

BDS280

+

BDH114

+

BDTL25

200 — 800A Switches, 600V
UL General
Purpose
Amp Rating

2 pole
200
400
600
800
3 pole
200
400
600
800
4 pole
200
400
600
800

FD400J3

FD600J3
FD800L3

Pistol Handles —
NEMA
Type

1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12

IEC
Type

IP65
IP65
IP65
IP65
IP65
IP65
IP65
IP65
IP65
IP65
IP65

.47 x .47" (
Color

Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Black
Red/Yellow
Metal

UL Fuse
Type
600V

Maximum Horsepower Rating
Three Phase
200V
208V
240V
480V

J1
J1
J1
L

—
—
—
—

—
—
—
—

—
—
—
—

—
—
—
—

—
—
—
—

J1
J1
J1
L

50
100
150
200

50
125
150
200

60
125
200
250

125
250
400
500

150
350
500
600

J1
J1
J1
L

50
100
150
200

50
125
150
200

60
125
200
250

125
250
400
500

150
350
500
600

12 x 12 mm)

Catalog
Number

600V

BDH112

2 pole
FD200J2
FD400J2
FD600J2
FD800L2
3 pole
FD200J3
FD400J3
FD600J3
FD800L3
4 pole
FD200J4
FD400J4
FD600J4
FD800L4

BDH113

Length
(inches/mm)

Marking

Defeatable

Padlockable

Weight
(lbs.)

Catalog
Number

4.9/125
4.9/125
5.7/145
5.7/145
6.9/175
6.9/175
5.7/145
5.7/145
6.9/175
6.9/175
8.7/220

O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
Off/On

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

0.39
0.39
0.39
0.39
0.41
0.41
0.39
0.39
0.41
0.41
1.50

BDH112
BDH113
BDH114
BDH115
BDH116
BDH117
CDHXB12
CDHXY12
CDHXB22
CDHXY22
BDH8

1 J type fuse clips are standard. If 600V Type “T” clips are desired, please order a "T" type fuse adapter kit.

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006

104

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Accessories

For 200A - 800A Fusible Disconnect Switches
Shafts

—

.47 x .47" (

Shaft Length
(inches/mm)

12 x 12 mm)
Mounting Depth1
(in inches)

For use on FD200J_ – FD400J_
8.7/220
9.8/250
11.0/280
12.8/325
15.6/395
18.3/465
21.1/535
For use on FD600J_ – FD800J_
9.8/250
11.0/280
12.8/325
15.6/395
18.3/465
21.1/535

BDS_

Weight
(lbs.)

Catalog
Number

7.9
9.1
10.2
12.0
14.8
17.5
20.3

–
–
–
–
–
–
–

12.2
13.4
14.5
16.3
19.1
21.9
24.6

0.61
0.70
0.77
0.90
1.10
1.32
1.54

BDS220
BDS250
BDS280
BDS325
BDS395
BDS465
BDS535

10.0
11.2
13.0
15.8
18.5
21.1

–
–
–
–
–
–

12.8
14.0
15.8
18.6
21.3
24.1

0.70
0.77
0.90
1.10
1.32
1.54

BDS250
BDS280
BDS325
BDS395
BDS465
BDS535

Twisted Shafts
Rotates handle 45°

.47 x .47" (

Shaft Length
(inches/mm)

For use on FD200J_ – FD400J_
11.0/280
12.8/325
18.3/465
For use on FD600J_ – FD800J_
11.0/280
12.8/325
18.3/465

BDS_45

12 x 12 mm)

Mounting Depth
(in inches)

Weight
(lbs.)

Catalog
Number

10.2 – 14.5
12.0 – 16.3
17.5 – 21.9

0.77
0.90
1.32

BDS28045
BDS32545
BDS46545

11.2 – 14.0
13.0 – 15.8
18.5 – 21.3

0.77
0.90
1.32

BDS28045
BDS32545
BDS46545

BDTL25

Terminal Lug Kit
BDTL26
For Use On:

BDTL27

FD200J_
FD200J
FD400J_
FD600J – FD800L
FD600J_ & FD800L_

Wire Size

#6 –
(6) #14 –
#2 –
(12) #14 –
(2) #2 –

Kit Weight
(lbs.)

Wire
Type

Terminal
Lugs Per Kit

Catalog
Number

0.93
0.93
3.50
1.10
4.62

Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al

6
3
6
3
6

BDTL25
BDTL175
BDTL26
BDTL175/400
BDTL27

300 kcmil
6 kcmil
600 kcmil
16–600 kcmil
600 kcmil

BDTL175/400

BDTL175

“T” Type Fuse Adapter Kit
For Use On:

AC Thermal
Amp Rating

AC Rated
Voltage

Poles

Catalog
Number

FD200J_
FD400J_
FD600J_

200
400
600

600
600
600

3
3
3

BDTA2
BDTA4
BDTA6

BDTA
1 Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length.

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

105

Overview

Bussmann®

For Non-Fusible Disconnect Switches CDNF16 - CDNF160

Catalog Number
General Purpose
Amp Rating
Approvals1

CDNF160

CDNF30 CDNF60 CDNF100

CDNF16 CDNF25 CDNF32

3 pole

CDNF16

CDNF25

CDNF32

CDNF45

CDNF63

CDNF30

CDNF100

CDNF160

A

16

25

40

60

80

30

60

100

125

2 pole
3 pole
4 pole

N/A
UL508
UL508

N/A
UL508
UL508

N/A
UL508
UL508

N/A
UL508
UL508

N/A
UL508
UL508

N/A
UL98
UL98

N/A
UL98
UL98

N/A
UL98
UL98

UL98
UL98
UL98

600

600

600

600

600

600

600

600

600

3
5
10
10

7.5
7.5
15
20

10
10
20
25

15
15
30
30

20
20
40
40

10
10
20
30

20
20
40
40

25
30
50
50

30
30
75
100

1/2
1.5

3/4
2

1
3

2
5

2
5

2
5

3
7.5

5
15

7.5
20

750

750

750

750

750

750

750

750

750

25
25
16
16

32
32
25
25

40
40
32
32

63
63
63
63

80
80
80
80

40
40
40
40

63
63
63
63

115
115
100
100

200
160
160
160

7.5
7.5

9
9

11
11

22
15

37
18.5

15
15

18.5
15

37
37

75
75

0.24
2.68
1.38
2.20

0.24
2.68
1.38
2.20

0.24
2.68
1.38
2.20

0.59
3.60
2.07
2.85

0.59
3.60
2.07
2.85

0.79
3.94
2.76
2.95

0.79
3.94
2.76
2.95

0.79
3.94
2.76
2.95

2.42
5.00
4.96
2.93

Integral
•
•

Integral
•
•

Integral
•
•

Integral
•
•

Integral
•
•

Integral
•
•

Integral
•
•

Integral
•
•

Integral
•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

—
•

—
•

—
•

—
•

•
•
•
•
—

•
•
•
•
—

•
•
•
•
—

•
•
•
•
—

•
•
•
•
—

•
•
•
•
—

•
•
•
•
—

•
•
•
—
—

•
•
•
•
—

Technical Ratings
UL,CSA
Max operating voltage
V
Max horsepower rating
Three phase
200 – 208V
HP
240V
HP
480V
HP
600V
HP
Single phase
120V
HP
240V
HP
Technical Ratings
IEC
Rated insulation and
operational voltage.
ac20 and dc20
V
Rated thermal current, Ith
ac 20/dc 20 open
A
ac 20/dc 20 enclosed
A
ac 21A
500V
A
690V
A
Rated operational power ac23
400/415V kW
690V
kW
Physical Characteristics
Weight
3 pole
lb
Dimension 3 pole]
H in
W in
D in
Accessories
Terminal lug kit
Terminal shroud
Auxiliary contact
Handle UL/NEMA type
Type 1, 3R, 12
Type 1, 3R, 4, 4X, 12
Handle type
Selector
Pistol
Conversion kits
6 pole
Transfer
Bypass
Mechanical interlock
Electrical interlock

• = Available
— = Not available
1 UL listed switches are also CSA approved.

CDNF60

UL listed, CSA approved, IEC rated, CE marked

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006

106

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Overview

For Non-Fusible Disconnect Switches BDNF200A - BDNF3150

BDNF175A

Catalog Number
General Purpose
Amp Rating
Approvals1

BDNF200A

3 pole
A
2 pole
3 pole
4 pole

Technical Ratings
UL, CSA
Max operating voltage
V
Max horsepower rating
Three phase
200 – 208V
HP
240V
HP
480V
HP
600V
HP
Single phase
120V
HP
240V
HP
Technical Ratings
IEC
Rated insulation and
operational voltage.
ac20 and dc20
V
Rated thermal current, Ith
ac 20/dc 20
open
A
ac 20/dc 20
enclosed
A
ac 21A
500V
A
690V
A
Rated operational power ac23
400/415V kW
690V
kW
Physical Characteristics
Weight
3 pole
lb
Dimension
3 pole H in
W in
D in
Accessories
Terminal lug kit
Terminal shroud
Auxiliary contact
Handle UL/NEMA type
Type 1, 3R, 12
Type 1, 3R, 4, 4X, 12
Handle type
Selector
Pistol
Conversion kits
6 pole
Transfer
Bypass
Mechanical interlock
Electrical interlock

BDNF400A

BDNF600A

BDNF800A

BDNF1200

BDNF1600

BDNF2000

BDNF3150

BDNF175A BDNF200A BDNF400 BDNF600A BDNF800A BDNF1200 BDNF1600 BDNF2000
175

200

400

600

800

UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC
UL508 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC
IEC
IEC
UL98 & IEC UL98 & IEC
IEC

1200

1600

UL98 & IEC UL98 & IEC
UL98 & IEC UL98 & IEC
IEC
IEC

2000

BDNF3150
3150

UL98 & IEC
UL98 & IEC
IEC

IEC
IEC
IEC

600

600

600

600

600

600

600

600

600

30
40
75
100

60
75
150
200

100
125
250
350

150
200
400
500

200
250
500
600

—
—
—
—

—
—
—
—

—
—
—
—

—
—
—
—

—
—

—
—

—
—

—
—

—
—

—
—

—
—

—
—

—
—

1000

1000

1000

1000

1000

1000

1000

1000

1000

200
200
200
200

315
270
250
250

630
630
630
630

800
720
800
800

1250
1250
1250
1250

1600
1600
1600
1600

2500
2300
2500
2500

2500
2300
2500
2500

3150
2600
3150
3150

90
170

132
200

315
355

355
355

400
—

400
—

400
—

400
—

400
—

6.61
8.35
7.83
4.55

6.61
8.35
8.62
4.55

13.66
11.81
10.24
5.12

13.66
11.77
11.93
5.12

35.9
19.09
14.29
4.92

38.55
19.09
14.29
4.92

127.7
25.04
18.43
10.67

127.7
25.04
18.43
10.67

127.7
25.04
18.43
10.67

BDTL25
•
•

BDTL25
•
•

BDTL26
•
•

BDTL27
•
•

BDTL30
•
•

BDTL28
•
•

BDTL28
—
•

BDTL28/2
—
•

BDTL28/2
—
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

•
•

—
•

—
•

—
•

—
•

—
•

—
•

—
•

—
•

—
•

•
•
•
•
•

•
•
•
•
•

•
•
•
•
•

•
•
•
•
•

•
•
•
•
•

•
•
•
•
•

—
—
—
•
•

—
—
—
•
•

—
—
—
•
•

S = Standard feature
• = Available
— = Not available
1 UL listed switches are also CSA approved.

UL listed, CSA approved, IEC rated, CE marked

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

107

16A - 100A

Bussmann®

For Non-Fusible Disconnect Switches

Base & DIN Rail Mounted

For a complete assembly,
please select one of each:
1 switch
1 handle
1 shaft
CDNF63

+

CDS85S

+

CDH3S

16 — 100 Amp Switches, 600V, 3 Pole1
CDNF16
CDNF25
CDNF32

CDNF30
CDNF60
CDNF100

UL
General
Purpose
Amp Rating

IEC
AC21
Amp
Rating

16
25
40
60
80
30
60
100

16
25
40
63
80
40
63
115

Maximum Horsepower Rating
Single Phase
120V
240V

1/2
3/4
1
2
2
2
3
5

Selector Handles
NEMA
Type
I ON

O OFF

CDH1S

CDH15S

CDH6S

IEC
Type

1.5
2
3
5
5
5
7.5
15

5
7.5
10
15
20
10
20
30

10
15
20
30
40
20
40
50

10
20
25
30
40
30
40
50

— For use with shafts

Color

All marked both O/I & Off/On
1
IP54
Black
1
IP54
Red/Yellow
1
IP54
Black
1
IP54
Red/Yellow
1,3R,12
IP65
Black
1,3R,12
IP65
Red/Yellow
1,3R,12
IP65
Black
1,3R,12
IP65
Red/Yellow

Shafts

Terminal Lugs

Three Phase
240V
480V 600V

Wire
Size

Wire
Type

Catalog
Number

#18 – 8
#18 – 8
#18 – 8
#14 – 4
#14 – 1
#14 – 4
#14 – 4
#8 – 1/0

CU
CU
CU
CU
CU
CU
CU
CU

CDNF16
CDNF25
CDNF32
CDNF45
CDNF63
CDNF30
CDNF60
CDNF100

.20 x .20" (

5 x 5 mm)

Defeatable

Padlockable

Weight
(lbs)

Catalog
Number

—
—
—
—
—
—
Yes
Yes

—
—
Yes
Yes
Yes
Yes
Yes
Yes

0.09
0.09
0.12
0.12
0.16
0.16
0.16
0.16

CDH1S2
CDH2S2
CDH15S2
CDH16S2
CDH3S
CDH4S
CDH5S
CDH6S

— For use with CDH selector handles

.20 x .20" (

5 x 5 mm)

Mounting depth3 in inches

Shaft
Length
(inches
/mm)

CDS_ S

3.3/85
4.1/105
4.7/120
5.1/130
7.1/180
9.8/250
13/330

CDNF16
CDNF25
CDNF32
CDH1S
CDH2S
CDH15S
CDH16S

4.2
5.0
5.6
6.0
7.1
10.7
13.8

–
–
–
–
–
–
–

5.0
5.8
6.4
6.7
8.7
11.5
14.6

CDNF45
CDNF63
CDH3S
CDH4S
CDH5S
CDH6S

3.6
4.4
5.0
5.4
7.4
10.1
13.3

–
–
–
–
–
–
–

4.3
5.1
5.8
6.1
8.1
10.8
14.0

CDH1S
CDH2S
CDH15S
CDH16S

4.9
5.7
6.3
6.7
8.6
11.4
14.6

–
–
–
–
–
–
–

5.6
6.4
7.0
7.4
9.4
12.1
15.3

CDNF30
CDNF60
CDNF100
CDH3S
CDH4S
CDH5S
CDH6S

CDH3S
CDH4S
CDH5S
CDH6S

4.4
5.1
5.7
6.1
8.1
10.9
14.0

–
–
–
–
–
–
–

5.0
5.8
6.4
6.8
8.7
11.5
14.7

3.9
4.7
5.3
5.6
7.6
10.4
13.5

–
–
–
–
–
–
–

4.9
5.7
6.3
6.7
8.6
11.4
14.5

Weight
(lbs.)

Catalog
Number

0.04
0.04
0.05
0.05
0.08
0.10
0.14

CDS85S
CDS105S
CDS120S
CDS130S
CDS180S
CDS250S
CDS330S

1 A snap on fourth pole may be added
2 Not suitable for use with CDNF30, 60, 100.
3 Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length.

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006

108

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Handles & Shafts

For 16A-100A Non-Fusible Disconnect Switches
Base & DIN Rail Mounted
Pistol Handles
NEMA
Type
BDH104, 106

BDH107

1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12,4,4X
1,3R,12,4,4X

Shafts

— For use with shafts

IEC
Type

Color

IP65
IP65
IP65
IP65
IP66
IP66

Black
Red/Yel
Black
Red/Yel
Black
Red/Yel

Marking

O/I
O/I
O/I
O/I
O/I
O/I

&
&
&
&
&
&

.20 x .20" (

5 x 5 mm)

Length
(inches/mm)

Defeatable

Padlockable

Weight
(lbs.)

Catalog
Number

1.8/45
1.8/45
2.6/65
2.6/65
2.6/65
2.6/65

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

0.28
0.28
0.29
0.29
0.29
0.29

BDH104
BDH105
BDH106
BDH107
CDHXB65
CDHXY65

Off/On
Off/On
Off/On
Off/On
Off/On
Off/On

— For use with pistol handles

.20 x .20" (

5 x 5 mm)

Mounting depth1 in inches
Shaft
Length
(inches/mm)
CDS_P

CDNF16
CDNF25
CDNF32

5.9/150
6.7/170
10.4/265
15.8/400
19.7/500

6.2
7.0
10.7
16.0
20.0

–
–
–
–
–

6.7
7.5
11.3
16.6
20.5

CDNF45
CDNF63

6.9
7.7
11.4
16.8
20.7

–
–
–
–
–

7.4
8.1
11.9
17.2
21.1

CDNF30
CDNF60
CDNF100

6.4
7.2
10.9
16.2
20.1

–
–
–
–
–

7.4
8.1
11.9
17.2
21.1

Weight
(lbs.)

Catalog
Number

0.07
0.08
0.12
0.18
0.23

CDS48P
CDS67P
CDS49P
CDS50P
CDS99P

Weight
(lbs.)

Catalog
Number

0.07
0.08
0.12
0.18

CDS48T
CDS67T
CDS49T
CDS50T

Twisted Shafts
Rotates handle 45°

.20 x .20" (

5 x 5 mm)

Mounting depth1 in inches

CDS_T

Shaft
Length
(inches/mm)

CDNF16
CDNF25
CDNF32

5.9/150
6.7/170
10.4/265
15.8/400

6.2
7.0
10.7
16.0

–
–
–
–

6.7
7.5
11.3
16.6

CDNF45
CDNF63

6.9
7.7
11.4
16.8

–
–
–
–

7.4
8.1
11.9
17.2

CDNF30
CDNF60
CDNF100

6.4
7.2
10.9
16.2

–
–
–
–

Replacement Knob

OPMRH

Mounts directly to switch; no shaft necessary
CDBY68419/1

NEMA
Type

1
1
1
Metal collar
Set screw

Color

Red
Red
Red

For Use On:

CDNF16, 25, 32
CDNF30, 45, 60, 63,100
CDNF30, 45, 60, 63,100
CDNF16 – CDNF100
CDNF16, 25, 30, 32, 45, 60, 63, 100

7.4
8.1
11.9
17.2

Length
(inches)

1.0
1.4
1.6
—
—

CDBY68306

Padlockable

—
—
Yes2
—
—

Catalog
Number

OPMRH
CDBY683063
CDBY68419/13
CDMC1
CDSWM5X8

CDMC1
1 Mounting depth is the distance from the outside of door to the disconnect switch mounting plate. Shaft can be cut to desired length.
2 .1875" (3/16") diameter shackle required.
3 Set screw CDSWM5X8 needed with replacement knobs CDBY__.

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

109

16A - 100A

Bussmann®

Non-Fusible Disconnect Switches Door Mounted
For a complete assembly,
please select one of each:
1 switch
1 handle

CDNF45D

CDH9S

16 — 100 Amp Switches, 600V, 3 Pole123
UL
General
Purpose
Amp Rating

16
25
40
604
804
304
604
1004

CDNF16D
CDNF25D
CDNF32D

CDH8S
CDH12S

O OFF

CDH17S
CDH19S

CDH9S
CDH13S

16
25
40
63
80
40
63
115

Maximum Horsepower Rating
Single Phase
Three Phase
120V
240V
240V 480V
600V

1/2
3/4
1
2
2
2
3
5

1.5
2
3
5
5
5
7.5
15

5
7.5
10
15
20
10
20
30

10
15
20
30
40
20
40
50

10
20
25
30
40
30
40
50

Terminal Lugs
Wire
Wire
Size
Type

#18 – 8
#18 – 8
#18 – 8
#14 – 4
#14 – 1
#14 – 4
#14 – 4
#8 – 1/0

Catalog
Number

CU
CU
CU
CU
CU
CU
CU
CU

CDNF16D
CDNF25D
CDNF32D
CDNF45D
CDNF63D
CDNF30D
CDNF60D
CDNF100D

Selector Handles
NEMA/UL
Type

I ON

IEC
AC21
Amp
Rating

IEC
Type

Color

Defeatable

Padlockable

All marked both O/I & Off/On
Snap-on mounting — for use on CDNF16, 25, 32D
1
IP54
Black
—
—
1
IP54
Red/Yellow
—
—
1
IP54
Black
—
Yes
1
IP54
Red/Yellow
—
Yes
1,3R,12
IP65
Black
—
Yes
1,3R,12
IP65
Red/Yellow
—
Yes
Screw mounting — for use on CDNF16, 32, 45 & 63D
1
IP54
Black
—
—
1
IP54
Red/Yellow
—
—
1
IP54
Black
—
Yes
1
IP54
Red/Yellow
—
Yes
1,3R,12
IP65
Black
—
Yes
1,3R,12
IP65
Red/Yellow
—
Yes

Weight
(lbs)

Catalog
Number

0.10
0.10
0.13
0.13
0.17
0.17

CDH7S
CDH8S
CDH19S
CDH20S
CDH9S
CDH10S

0.11
0.11
0.14
0.14
0.18
0.18

CDH11S
CDH12S
CDH17S
CDH18S
CDH13S
CDH14S

Door mounted switches do not provide door interlock
CDH10S
CDH14S

Pistol Grip Handle Adapter
Description

Adapter piece
for pistol grip handle
1
2
3
4

For Use On:

CDNF30, CDNF60,
CDNF100

Weight
(lbs)

Catalog
Number

0.18

CDHZX6

A snap on fourth pole may be added
Door mounted switches do not require shafts.
CDNF16, 25, 32, 45 & 63 door mounted switches will not accept pistol handles.
CDNF45 & 63 door mounted switches can only use screw mounted handles.

For additional information and detail see the Bussmann Disconnect Switch Catalog item number 3006

110

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

400A – 800A

Non-Fusible Disconnect Switches
For a complete assembly,
please select one of each:
1 switch
1 handle
1 shaft
1 terminal lug kit

BDH116

BDS280

BDNF400

BDTL26

400 – 800 Amp switches, 600V

BDNF600A

BDNF800A

BDH112-117

UL
general
purpose
amp rating
2 pole
400
600
800
3 pole
400
600
800
4 pole
400
600
—

IEC
AC21
amp
rating

Maximum horsepower rating
200V

208V

240V

480V

600V

630
800
1250

—
—
—

—
—
—

—
—
—

—
—
—

—
—
—

BDNF4002
BDNF600A2
BDNF800A2

630
800
1250

100
150
200

100
150
200

125
200
250

250
400
500

350
500
600

BDNF400
BDNF600A
BDNF800A

630
800
1250

100
150
200

100
150
200

125
200
250

250
400
500

350
500
600

BDNF4004
BDNF600A4
BDNF800A4

Pistol handles — for use with shafts
NEMA
type

IEC
type

Color

Length
in/mm

Marking

1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12

IP65
IP65
IP65
IP65
IP65
IP65
IP66
IP66
IP66
IP65

Blk
R/Y
Blk
R/Y
Blk
R/Y
Blk
R/Y
Blk
Metal

4.9/125
4.9/125
5.7/145
5.7/145
6.9/175
6.9/175
5.7/145
5.7/145
6.9/175
8.7/220

O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
O/I & Off/On
Off/On

Shafts — for use with pistol handles

BDS280

Shaft length
inches/mm
11.0/280
12.8/325
15.6/395
18.3/465
21.1/535

.47 x .47” (

.47 x .47" (

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Weight
(lbs)
0.77
0.90
1.10
1.32
1.54

.47 x .47" (

Mounting depth1
in inches
10.2 – 14.5
12.0 – 16.3
17.5 – 21.9

Weight
(lbs)

Catalog
number

0.39
0.39
0.39
0.39
0.41
0.41
0.39
0.39
0.41
1.50

BDH112
BDH113
BDH114
BDH115
BDH116
BDH117
CDHXB12
CDHXY12
CDHXB22
BDH8

12 x 12 mm)

Mounting depth1
in inches
10.2 – 14.5
12.0 – 16.3
14.8 – 19.1
17.5 – 21.9
20.3 – 24.6

Twisted shafts — Rotates handle 45°
Shaft length
inches/mm
11.0/280
12.8/325
18.3/465

12 x 12 mm)

Defeatable Padlockable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—

Catalog
number

Catalog
number
BDS280
BDS325
BDS395
BDS465
BDS535

12 x 12 mm)
Weight
(lbs)
0.77
0.90
1.32

Catalog
number
BDS28045
BDS32545
BDS46545

BDS_45
1 Mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length.

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

111

Accessories

Bussmann®

for 400A – 800A Non-Fusible Disconnect Switches
Terminal lug kits
For use on:

BDTL26

BDTL30

BDTL27

BDTL175/400

Wire
size

BDNF400
BDNF400
BDNF600A
BDNF800A
BDNF800A1
BDNF400 – BDNF600A1

#2
(2) #2
(2) #2
(2) #2
(8) 2/0
(12) #14

Auxiliary contacts

2

–
–
–
–
+
–

600 kcmil
500 kcmil
600 kcmil
600 kcmil
(2)#2 600 kcmil
6

Description

For use on:

1 N.O. + 1 N.C.
2 N.O. + 2 N.C.
4 N.O. + 4 N.C
2 N.O.
4 N.O.
8 N.O.

BDNF400 –
BDNF800A

Kit weight
(lbs.)

Wire
type

Terminal
lugs per kit

Kit catalog
number

3.50
4.62
4.62
6.90
6.90
1.10

CU/AL
CU/AL
CU/AL
CU/AL
CU/AL
CU/AL

6
6
6
6
3
3

BDTL26
BDTL262
BDTL27
BDTL30
BDTL32
BDTL175/400

Weight
(lbs)
0.20
0.26
0.40
0.18
0.25
0.40

ac thermal
amp rating
10
10
10
10
10
10

Weight
(lbs)

ac thermal
amp rating

ac rated
voltage

Catalog
number

1.04

400

600

BDZX85

ac rated
voltage
600
600
600
600
600
600

Catalog
number
BDAUX1
BDAUX2
BDAUX3
BDAUX4
BDAUX5
BDAUX6

BDTL32

Terminal poles
Description

For use on:

Detachable neutral
mounts on side of
switch or DIN rail

BDNF400 –
BDNF600A

BDAUX1-6

Terminal shrouds
Description

For use on:

Weight
(lbs)

Catalog
number

Includes one
shroud for line or
load side

BDNF400
BDNF600A
BDNF800A

0.62
0.66
0.88

BDTS4
BDTS6A
BDTS8A

BDZX85

Handle support bracket
Description

For use on:

Weight
(lbs)

Catalog
number

Allows handle to be directly
mounted to switch
behind the door

BDNF400 –
BDNF600A
BDNF800A

0.51

BDZX73

0.88

BDZX71

BDTS_

1 A load side distribution lug eliminates the need to purchase, install and wire a separate distribution block.
2 UL File E57057

BDZX71

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006

112

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Enclosed Fusible Disconnect Switches

30A – 800A

EFJ30X-3PB6

3 Pole1, 600V, 30A – 3150A
UL General purpose
amp rating
30
30
60
100
200
400
600
800

1
Catalog
number
EFJ301-3PB6
EFC301-3PB6
EFJ601-3PB6
EFJ1001-3PB8
EFJ2001-3PB4
EFJ4001-3PB4
EFJ6001-3PB4
EFL8001-3PB4

Fuse
Type
J
CC
J2
J2
J2
J2
J2
J2

NEMA / UL Enclosure type
3R
4
Catalog
Catalog
number
number
EFJ303-3PB6
EFJ304-3PB6
EFC303-3PB6
EFC304-3PB6
EFJ603-3PB6
EFJ604-3PB8
EFJ1003-3PB8
EFJ1004-3PB8
EFJ2003-3PB4
EFJ2004-3PB4
EFJ4003-3PB4
EFJ4004-3PB4
EFJ6003-3PB4
EFJ6004-3PB4
EFL8003-3PB4
EFL8004-3PB4

4X Stainless
Catalog
number
EFJ30X-3PB6
EFC30X-3PB6
EFJ60X-3PB8
EFJ100X-3PB8
EFJ200X-3PB4
EFJ400X-3PB4
EFJ600X-3PB4
EFL800X-3PB4

Switch ratings
UL general
purpose
amp rating
30
60
100
200
400
600
800

Maximum horsepower rating
Single phase
Three phase
120V
200V
240V
200V
208V
240V
480V
2
3
5
—
—
—
—

3
7.5
10
—
—
—
—

5
10
15
—
—
—
—

5
15
25
50
100
150
200

7.5
15
25
50
125
150
200

7.5
15
30
60
125
200
250

15
30
60
125
250
400
500

Wire size for terminal lugs

For wire type

Approval1

600V
20
50
75
150
350
500
600

#18
#14
#14
#6
#2
(2) #2
(2) #2

–
–
–
–
–
–
–

8
4
2/0
300
600
600
600

kcmil
kcmil
kcmil
kcmil

CU
CU
CU/AL
CU/AL
CU/AL
CU/AL
CU/AL

CSA,
CSA,
CSA,
CSA,
CSA,
CSA,
CSA,

UL
UL
UL
UL
UL
UL
UL

1 Fusible switches are UL listed to the UL98 standard.
2 600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T."

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

113

Enclosed Fusible Disconnect Switches

Bussmann®

30A – 800A

EFJ607-3P

3 Pole1, 600V, 30A – 3150A
UL General purpose
amp rating
30
30
60
100
200
400
600
800

4X Plastic
Catalog
number
EFJ30P-3PB6
EFC30P-3PB6
EFJ60P-3PB8
EFJ100P-3PB8
EFJ200P-3PB4
EFJ400P-3PB4
EFJ600P-3PB4
EFL800P-3PB4

Fuse
Type
J
CC
J2
J2
J2
J2
J2
J2

NEMA / UL Enclosure type
12
Catalog
number
EFJ302-3PB6
EFC302-3PB6
EFJ602-3PB6
EFJ1002-3PB8
EFJ2002-3PB4
EFJ4002-3PB4
EFJ6002-3PB4
EFL8002-3PB4

7&9
Catalog
number
EFJ307-3PB
EFC307-3PB
EFJ607-3PB
EFJ1007-3PB
EFJ2007-3PB
EFJ4007-3PB
EFJ6007-3PB
EFL8007-3PB

Handle ratings
Amperage
range

30

60 – 100

200 – 800

1
2

Style
type
Selector
Selector
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol
Pistol

NEMA

Color

Marking

Defeatable

Padlockable

1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,12
1,3R,12
1,3R,12
1,3R,12
1,3R 4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12
1,3R,4,4X,12

Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Black
Red/Yel
Metal

0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On
0/I & Off/On

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Catalog number
suffix
BJ
YJ
B6
Y6
B6
Y6
B6
Y6
B8
Y8
B8
Y8
B4
Y4
B7
Y7
B4
Y4
B7
Y7
8

Catalog
number
CDH5S
CDH6S
BDH106
BDH107
CDHXB65
CDHXY65
BDH58
BDH59
BDH60
BDH61
CDHXB86
CDHXY86
BDH114
BDH115
BDH116
BDH117
CDHXB12
CDHXY12
CDHXB22
CDHXY22
BDH8

Fusible switches are UL listed to the UL98 standard.
600V T type fuse clips may be substituted at no charge. Please change the second character of the catalog number from "J" to "T."

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006

114

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Other Configurations

for Enclosed Fusible Disconnect Switches
UL
general purpose
amp rating

30 (J fuses)

30 (CC fuses)

60

100

200

400

600

800

2 Pole

Type of Switch

4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
4 Pole1
6 Pole
Transfer
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock

30A – 800A

1

NEMA Enclosure type
3R

4

4X Stainless

Catalog
number

Catalog
number

Catalog
number

Catalog
number

EFJ301-4PB6
EFJ301-6PB6
EFJ301-3TB8
EFJ301-3BB6
EFJ301-3MB6
EFC301-4PB6
EFC301-6PB6
EFC301-3TB8
EFC301-3BB6
EFC301-3MB6
EFJ601-4PB6
EFJ601-6PB4
EFJ601-3TB8
EFJ601-3MB6
EFJ1001-2PB8
EFJ1001-4PB8
EFJ1001-6PB4
EFJ1001-3TB8
EFJ1001-3MB8
EFJ2001-2PB8
EFJ2001-4PB4
EFJ2001-6P8
EFJ2001-3TB4
EFJ2001-3B6
EFJ2001-3MB4
EFJ4001-2PB4
EFJ4001-4PB4
EFJ4001-6P8
EFJ4001-3TB4
EFJ4001-3B6
EFJ4001-3MB4
EFJ6001-2PB4
EFJ6001-4PB4
EFJ6001-6P8
EFJ6001-3TB4
EFJ6001-3B6
EFJ6001-3MB4
EFL8001-2PB4
EFL8001-4PB4
EFL8001-6P8
EFL8001-3TB4
EFL8001-3B6
EFL8001-3MB4

EFJ303-4PB6
EFJ303-6PB6
EFJ303-3TB8
EFJ303-3BB6
EFJ303-3MB6
EFC303-4PB6
EFC303-6PB6
EFC303-3TB8
EFC303-3BB6
EFC303-3MB6
EFJ603-4PB6
EFJ603-6PB4
EFJ603-3TB8
EFJ603-3MB6
EFJ1003-2PB8
EFJ1003-4PB8
EFJ1003-6PB4
EFJ1003-3TB8
EFJ1003-3MB8
EFJ2003-2PB8
EFJ2003-4PB4
EFJ2003-6P8
EFJ2003-3TB4
EFJ2003-3B6
EFJ2003-3MB4
EFJ4003-2PB4
EFJ4003-4PB4
EFJ4003-6P8
EFJ4003-3TB4
EFJ4003-3B6
EFJ4003-3MB4
EFJ6003-2PB4
EFJ6003-4PB4
EFJ6003-6P8
EFJ6003-3TB4
EFJ6003-3B6
EFJ6003-3MB4
EFL8003-2PB4
EFL8003-4PB4
EFL8003-6P8
EFL8003-3TB4
EFL8003-3B6
EFL8003-3MB4

EFJ304-4PB6
EFJ304-6PB6
EFJ304-3TB8
EFJ304-3BB6
EFJ304-3MB6
EFC304-4PB6
EFC304-6PB6
EFC304-3TB8
EFC304-3BB6
EFC304-3MB6
EFJ604-4PB6
EFJ604-6PB4
EFJ604-3TB8
EFJ604-3MB6
EFJ1004-2PB8
EFJ1004-4PB8
EFJ1004-6PB4
EFJ1004-3TB8
EFJ1004-3MB8
EFJ2004-2PB8
EFJ2004-4PB4
EFJ2004-6P8
EFJ2004-3TB4
EFJ2004-3B6
EFJ2004-3MB4
EFJ4004-2PB4
EFJ4004-4PB4
EFJ4004-6P8
EFJ4004-3TB4
EFJ4004-3B6
EFJ4004-3MB4
EFJ6004-2PB4
EFJ6004-4PB4
EFJ6004-6P8
EFJ6004-3TB4
EFJ6004-3B6
EFJ6004-3MB4
EFL8004-2PB4
EFL8004-4PB4
EFL8004-6P8
EFL8004-3TB4
EFL8004-3B6
EFL8004-3MB4

4 Pole

EFJ30X-4PB6
EFJ30X-6PB
EFJ30X-3TB8
EFJ30X-3BB6
EFJ30X-3MB6
EFC30X-4PB6
EFC30X-6PB6
EFC30X-3TB8
EFC30X-3BB6
EFC30X-3MB6
EFJ60X-4PB6
EFJ60X-6PB4
EFJ60X-3TB8
EFJ60X-3MB6
EFJ100X-2PB8
EFJ100X-4PB8
EFJ100X-6PB4
EFJ100X-3TB8
EFJ100X-3MB8
EFJ200X-2PB8
EFJ200X-4PB4
EFJ200X-6P8
EFJ200X-3TB4
EFJ200X-3B6
EFJ200X-3MB4
EFJ400X-2PB4
EFJ400X-4PB4
EFJ400X-6P8
EFJ400X-3TB4
EFJ400X-3B6
EFJ400X-3MB4
EFJ600X-2PB4
EFJ600X-4PB4
EFJ600X-6P8
EFJ600X-3TB4
EFJ600X-3B6
EFJ600X-3MB4
EFL800X-2PB4
EFL800X-4PB4
EFL800X-6P8
EFL800X-3TB4
EFL800X-3B6
EFL800X-3MB4

6 Pole

2

1
2

IEC rated only.
= Three poles

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

115

Bussmann®

Other Configurations

for Enclosed Fusible Disconnect Switches
UL
General purpose
amp rating

30 (J fuses)

30 (CC fuses)

60

100

200

400

600

800

Type of Switch

4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
4 Pole1
6 Pole
Transfer
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock
2 Pole1
4 Pole1
6 Pole
Transfer
Bypass
Mech. interlock

4X Plastic

NEMA Enclosure type
12

7&9

Catalog
number

Catalog
number

Catalog
number

EFJ30P-4PB6
EFJ30P-6PB6
EFJ30P-3TB8
EFJ30P-3BB6
EFJ30P-3MB6
EFC30P-4PB6
EFC30P-6PB6
EFC30P-3TB8
EFC30P-3BB6
EFC30P-3MB6
EFJ60P-4PB6
EFJ60P-6PB4
EFJ60P-3TB8
EFJ60P-3MB6
EFJ100P-2PB8
EFJ100P-4PB8
EFJ100P-6PB4
EFJ100P-3TB8
EFJ100P-3MB8
EFJ200P-2PB8
EFJ200P-4PB4
EFJ200P-6P8
EFJ200P-3TB4
EFJ200P-3B6
EFJ200P-3MB4
EFJ400P-2PB4
EFJ400P-4PB4
EFJ400P-6P8
EFJ400P-3TB4
EFJ400P-3B6
EFJ400P-3MB4
EFJ600P-2PB4
EFJ600P-4PB4
EFJ600P-6P8
EFJ600P-3TB4
EFJ600P-3B6
EFJ600P-3MB4
EFL800P-2PB4
EFL800P-4PB4
EFL800P-6P8
EFL800P-3TB4
EFL800P-3B6
EFL800P-3MB4

EFJ302-4PB6
EFJ302-6PB6
EFJ302-3TB8
EFJ302-3BB6
EFJ302-3MB6
EFC302-4PB6
EFC302-6PB6
EFC302-3TB8
EFC302-3BB6
EFC302-3MB6
EFJ602-4PB6
EFJ602-6PB4
EFJ602-3TB8
EFJ602-3MB6
EFJ1002-2PB8
EFJ1002-4PB8
EFJ1002-6PB4
EFJ1002-3TB8
EFJ1002-3MB8
EFJ2002-2PB8
EFJ2002-4PB4
EFJ2002-6P8
EFJ2002-3TB4
EFJ2002-3B6
EFJ2002-3MB4
EFJ4002-2PB4
EFJ4002-4PB4
EFJ4002-6P8
EFJ4002-3TB4
EFJ4002-3B6
EFJ4002-3MB4
EFJ6002-2PB4
EFJ6002-4PB4
EFJ6002-6P8
EFJ6002-3TB4
EFJ6002-3B6
EFJ6002-3MB4
EFL8002-2PB4
EFL8002-4PB4
EFL8002-6P8
EFL8002-3TB4
EFL8002-3B6
EFL8002-3MB4

Bypass

Transfer

30A – 800A

2

2

2

2

2

2

2

2

Mechanical
Interlock

3
3

3

1
2
3

IEC rated only.
Consult factory for pricing and availability.
= Three poles

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006

116

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Enclosed Non-Fusible Disconnect Switches

16A – 3150A

ENF321-3PBJ

ENF63X-3PB6

3 Pole, 600V, 16A – 100A — Selector handle
NEMA Enclosure type

UL general purpose
amp rating
16
25
40
60
80

1

3R

Catalog
number

Catalog
number

ENF161-3PBJ
ENF251-3PBJ
ENF321-3PBJ
ENF451-3PBJ
ENF631-3PBJ

41
Selector handles are only
NEMA rated 1, 3R, 12
Catalog
number

ENF163-3PBJ
ENF253-3PBJ
ENF323-3PBJ
ENF453-3PBJ
ENF633-3PBJ

ENF164-3PBJ
ENF254-3PBJ
ENF324-3PBJ
ENF454-3PBJ
ENF634-3PBJ

1
4X Stainless1
Selector handles are only
NEMA rated 1, 3R, 12
Catalog
number
ENF16X-3PBJ
ENF25X-3PBJ
ENF32X-3PBJ
ENF45X-3PBJ
ENF63X-3PBJ

3 Pole, 600V, 16A – 3150A — Pistol handle
NEMA Enclosure type

UL 98

UL 508

1

1
2

UL general purpose
amp rating
16
25
40
60
80
30
60
100
125
200
400
600
800
1200
1600
2000
31502

Catalog
number
ENF161-3PB6
ENF251-3PB6
ENF321-3PB6
ENF451-3PB6
ENF631-3PB6
ENF301-3PB6
ENF601-3PB6
ENF1001-3PB6
ENF1251-3PB6
ENF2001-3PB8
ENF4001-3PB4
ENF6001-3PB4
ENF8001-3PB4
ENF12001-3PB4
ENF16001-3P8
ENF20001-3P8
ENF31501-3P8

3R
Catalog
number
ENF163-3PB6
ENF253-3PB6
ENF323-3PB6
ENF453-3PB6
ENF633-3PB6
ENF303-3PB6
ENF603-3PB6
ENF1003-3PB6
ENF1253-3PB6
ENF2003-3PB8
ENF4003-3PB4
ENF6003-3PB4
ENF8003-3PB4
ENF12003-3PB4
ENF16003-3P8
ENF20003-3P8
ENF31503-3P8

4
Catalog
number
ENF164-3PB6
ENF254-3PB6
ENF324-3PB6
ENF454-3PB6
ENF634-3PB6
ENF304-3PB6
ENF604-3PB6
ENF1004-3PB6
ENF1254-3PB6
ENF2004-3PB8
ENF4004-3PB4
ENF6004-3PB4
ENF8004-3PB4
ENF12004-3PB4
ENF16004-3P8
ENF20004-3P8
ENF31504-3P8

4X Stainless
Catalog
number
ENF16X-3PB6
ENF25X-3PB6
ENF32X-3PB6
ENF45X-3PB6
ENF63X-3PB6
ENF30X-3PB6
ENF60X-3PB6
ENF100X-3PB6
ENF125X-3PB6
ENF200X-3PB8
ENF400X-3PB4
ENF600X-3PB4
ENF800X-3PB4
ENF1200X-3PB4
ENF1600X-3P8
ENF2000X-3P8
ENF3150X-3P8

Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12. The overall NEMA rating of an enclosed switch with a selector handle is 1, 3R, 12.
IEC rated only.

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

117

Enclosed Non-Fusible Disconnect Switches

Bussmann®

16A – 3150A

ENF25P-3PY6

ENF252-3PYJ

ENF16E-3PBJ

ENF45E-3PBJ

3 Pole, 600V, 16A – 100A — Selector handle
NEMA Enclosure type
4X Plastic1
Selector handles are only
NEMA rated 1, 3R, 12
UL general purpose
amp rating
16
25
40
60
80

Catalog
number
ENF16P-3PBJ
ENF25P-3PBJ
ENF32P-3PBJ
ENF45P-3PBJ
ENF63P-3PBJ

12
Catalog
number
ENF162-3PBJ
ENF252-3PBJ
ENF322-3PBJ
ENF452-3PBJ
ENF632-3PBJ

IEC Enclosure type
7&9
Catalog
number
—
—
—
—
—

IP65 Plastic
Catalog
number
ENF16E-3PBJ
ENF25E-3PBJ
ENF32E-3PBJ
ENF45E-3PBJ
ENF63E-3PBJ

3 Pole, 600V, 16A – 3150A — Pistol handle
NEMA Enclosure type

UL 98

UL 508

4X Plastic
UL general purpose
amp rating
16
25
40
60
80
30
60
100
125
200
400
600
800
1200
1600
2000
31502

NOTE:

EXAMPLE:

1
2

Catalog
number
ENF16P-3PB6
ENF25P-3PB6
ENF32P-3PB6
ENF45P-3PB6
ENF63P-3PB6
ENF30P-3PB6
ENF60P-3PB6
ENF100P-3PB6
ENF125P-3PB6
ENF200P-3PB8
ENF400P-3PB4
ENF600P-3PB4
ENF800P-3PB4
ENF1200P-3PB4
ENF1600P-3P8
ENF2000P-3P8
ENF3150P-3P8

12
Catalog
number
ENF162-3PB6
ENF252-3PB6
ENF322-3PB6
ENF452-3PB6
ENF632-3PB6
ENF302-3PB6
ENF602-3PB6
ENF1002-3PB6
ENF1252-3PB6
ENF2002-3PB8
ENF4002-3PB4
ENF6002-3PB4
ENF8002-3PB4
ENF12002-3PB4
ENF16002-3P8
ENF20002-3P8
ENF31502-3P8

IEC Enclosure type
7&9
Catalog
number
ENF167-3P
ENF257-3P
ENF327-3P
ENF457-3P
ENF637-3P
ENF307-3P
ENF607-3P
ENF1007-3P
ENF1257-3P
ENF2007-3P
ENF4007-3P
ENF6007-3P
ENF8007-3P
ENF12007-3P
ENF16007-3P
ENF20007-3
ENF31507-3P

IP65 Plastic
Catalog
number
ENF16E-3PB4
ENF25E-3PB4
ENF32E-3PB4
ENF45E-3PB4
ENF63E-3PB4
ENF30E-3PB6
ENF60E-3PB6
ENF100E-3PB6
ENF125E-3PB6
—
—
—
—
—
—
—
—

All enclosed switches are provided with a black handle; however, most handles can be substituted with a red and yellow handle if desired.
Please substitute the handle suffix code (2nd and 3rd from last characters) with the red/yellow handle catalog number suffix from page 3.12.
There is no additional price adder for changing to a red/yellow handle of equal ratings and style.
A red/yellow selector handle for an ENF161-3PBJA can be substituted for the black selector handle by using the "YJ" suffix instead of the "BJ"
suffix, new catalog #ENF161-3PYJA.

Enclosures are rated as listed, selector handles are only NEMA rated 1, 3R, 12. The overall NEMA rating of an enclosed switch with a selector handle is 1, 3R, 12.
IEC rated only.

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006

118

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Enclosed Non-Fusible Disconnect Switches

16A – 400A
UL
General purpose
amp rating

Other Configurations
NEMA Enclosure type
4
Catalog
number

1
Catalog
number

3R
Catalog
number

16

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF161-4PB6
ENF161-6PB6
ENF161-3TB8
ENF161-3BB8
ENF161-3MB6

ENF163-4PB6
ENF163-6PB6
ENF163-3TB8
ENF163-3BB8
ENF163-3MB6

ENF164-4PB6
ENF164-6PB6
ENF164-3TB8
ENF164-3BB8
ENF164-3MB6

ENF16X-4PB6
ENF16X-6PB6
ENF16X-3TB8
ENF16X-3BB8
ENF16X-3MB6

25

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF251-4PB6
ENF251-6PB6
ENF251-3TB8
ENF251-3BB8
ENF251-3MB6

ENF253-4PB6
ENF253-6PB6
ENF253-3TB8
ENF253-3BB8
ENF253-3MB6

ENF254-4PB6
ENF254-6PB6
ENF254-3TB8
ENF254-3BB8
ENF254-3MB6

ENF25X-4PB6
ENF25X-6PB6
ENF25X-3TB8
ENF25X-3BB8
ENF25X-3MB6

40

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF321-4PB6
ENF321-6PB6
ENF321-3TB8
ENF321-3BB8
ENF321-3MB6

ENF323-4PB6
ENF323-6PB6
ENF323-3TB8
ENF323-3BB8
ENF323-3MB6

ENF324-4PB6
ENF324-6PB6
ENF324-3TB8
ENF324-3BB8
ENF324-3MB6

ENF32X-4PB6
ENF32X-6PB6
ENF32X-3TB8
ENF32X-3BB8
ENF32X-3MB6

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF451-4PB6
ENF451-6PB6
ENF451-3TB8
ENF451-3BB8
ENF451-3MB6

ENF453-4PB6
ENF453-6PB6
ENF453-3TB8
ENF453-3BB8
ENF453-3MB6

ENF454-4PB6
ENF454-6PB6
ENF454-3TB8
ENF454-3BB8
ENF454-3MB6

ENF45X-4PB6
ENF45X-6PB6
ENF45X-3TB8
ENF45X-3BB8
ENF45X-3MB6

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF631-4PB6
ENF631-6PB6
ENF631-3TB8
ENF631-3BB8
ENF631-3MB6

ENF633-4PB6
ENF633-6PB6
ENF633-3TB8
ENF633-3BB8
ENF633-3MB6

ENF634-4PB6
ENF634-6PB6
ENF634-3TB8
ENF634-3BB8
ENF634-3MB6

ENF63X-4PB6
ENF63X-6PB6
ENF63X-3TB8
ENF63X-3BB8
ENF63X-3MB6

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF301-4PB6
ENF301-6PB6
ENF301-3TB8
ENF301-3BB8
ENF301-3MB6

ENF303-4PB6
ENF303-6PB6
ENF303-3TB8
ENF303-3BB8
ENF303-3MB6

ENF304-4PB6
ENF304-6PB6
ENF304-3TB8
ENF304-3BB8
ENF304-3MB6

ENF30X-4PB6
ENF30X-6PB6
ENF30X-3TB8
ENF30X-3BB8
ENF30X-3MB6

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF601-4PB6
ENF601-6PB6
ENF601-3TB8
ENF601-3BB8
ENF601-3MB6

ENF603-4PB6
ENF603-6PB6
ENF603-3TB8
ENF603-3BB8
ENF603-3MB6

ENF604-4PB6
ENF604-6PB6
ENF604-3TB8
ENF604-3BB8
ENF604-3MB6

ENF60X-4PB6
ENF60X-6PB6
ENF60X-3TB8
ENF60X-3BB8
ENF60X-3MB6

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF1001-4PB6
ENF1001-6PB6
ENF1001-3TB8
ENF1001-3BB8
ENF1001-3MB6

ENF1003-4PB6
ENF1003-6PB6
ENF1003-3TB8
ENF1003-3BB8
ENF1003-3MB6

ENF1004-4PB6
ENF1004-6PB6
ENF1004-3TB8
ENF1004-3BB8
ENF1004-3MB6

ENF100X-4PB6
ENF100X-6PB6
ENF100X-3TB8
ENF100X-3BB8
ENF100X-3MB6

2 Pole
4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF1251-2PB6
ENF1251-4PB6
ENF1251-6PB2
ENF1251-3TB8
—
ENF1251-3MB6

ENF1253-2PB6
ENF1253-4PB6
ENF1253-6PB2
ENF1253-3TB8
—
ENF1253-3MB6

ENF1254-2PB6
ENF1254-4PB6
ENF1254-6PB4
ENF1254-3TB8
—
ENF1254-3MB8

ENF125X-2PB6
ENF125X-4PB6
ENF125X-6PB4
ENF125X-3TB8
—
ENF125X-3MB8

2 Pole
4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF2001-2PB8
ENF2001-4PB8
ENF2001-6PB4
ENF2001-3TB4
ENF2001-3BB4
ENF2001-3MB8

ENF2003-2PB8
ENF2003-4PB8
ENF2003-6PB4
ENF2003-3TB4
ENF2003-3BB4
ENF2003-3MB8

ENF2004-2PB8
ENF2004-4PB8
ENF2004-6PB4
ENF2004-3TB4
ENF2004-3BB4
ENF2004-3MB8

ENF200X-2PB8
ENF200X-4PB8
ENF200X-6PB4
ENF200X-3TB4
ENF200X-3BB4
ENF200X-3MB8

2 Pole
4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF4001-2PB4
ENF4001-4PB4
ENF4001-6P8
ENF4001-3TB4
ENF4001-3B6
ENF4001-3MB4

ENF4003-2PB4
ENF4003-4PB4
ENF4003-6P8
ENF4003-3TB4
ENF4003-3B6
ENF4003-3MB4

ENF4004-2PB4
ENF4004-4PB4
ENF4004-6P8
ENF4004-3TB4
ENF4004-3B6
ENF4004-3MB4

ENF400X-2PB4
ENF400X-4PB4
ENF400X-6P8
ENF400X-3TB4
ENF400X-3B6
ENF400X-3MB4

60

80

30

60

100

125

200

400

Type of switch

4X Stainless
Catalog
number

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

119

Bussmann®

Enclosed Non-Fusible Disconnect Switches

16A – 400A
UL
General purpose
amp rating
16

25

40

60

80

30

60

100

125

200

400

Other Configurations
NEMA Enclosure type
12
Catalog
number

7&9
Catalog
number

IEC Enclosure type
IP65
Catalog
number

Type of switch

4X Plastic
Catalog
number

4 pole
6 pole
Transfer
Bypass
Mech. interlock

ENF16P-4PB6
ENF16P-6PB6
ENF16P-3TB8
ENF16P-3BB8
ENF16P-3MB6

ENF162-4PB6
ENF162-6PB6
ENF162-3TB8
ENF162-3BB8
ENF162-3MB6

ENF167-4P
ENF167-6P
ENF167-3T
ENF167-3B
—

ENF16E-4PBJ
ENF16E-6PBJ
—
—
—

4 pole
6 pole
Transfer
Bypass
Mech. interlock

ENF25P-4PB6
ENF25P-6PB6
ENF25P-3TB8
ENF25P-3BB8
ENF25P-3MB6

ENF252-4PB6
ENF252-6PB6
ENF252-3TB8
ENF252-3BB8
ENF252-3MB6

ENF257-4P
ENF257-6P
ENF257-3T
ENF257-3B
—

ENF25E-4PBJ
ENF25E-6PBJ
—
—
—

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF32P-4PB6
ENF32P-6PB6
ENF32P-3TB8
ENF32P-3BB8
ENF32P-3MB6

ENF322-4PB6
ENF322-6PB6
ENF322-3TB8
ENF323-3BB8
ENF322-3MB6

ENF327-4P
ENF327-6P
ENF327-3T
ENF327-3B
—

ENF32E-4PBJ
ENF32E-6PBJ
—
—
—

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF45P-4PB6
ENF45P-6PB6
ENF45P-3TB8
ENF45P-3BB8
ENF45P-3MB6

ENF452-4PB6
ENF452-6PB6
ENF452-3TB8
ENF452-3BB8
ENF452-3MB6

ENF457-4P
ENF457-6P
ENF457-3T
ENF457-3B
—

ENF45E-4PBJ
ENF45E-6PBJ
—
—
—

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF63P-4PB6
ENF63P-6PB6
ENF63P-3TB8
ENF63P-3BB8
ENF63P-3MB6

ENF632-4PB6
ENF632-6PB6
ENF632-3TB8
ENF632-3BB8
ENF632-3MB6

ENF637-4P
ENF637-6P
ENF637-3T
ENF637-3B
—

ENF63E-4PBJ
ENF637-6PBJ
—
—
—

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF30P-4PB6
ENF30P-6PB6
ENF30P-3TB8
ENF30P-3BB8
ENF30P-3MB6

ENF302-4PB6
ENF302-6PB6
ENF302-3TB8
ENF302-3BB8
ENF302-3MB6

ENF307-4P
ENF307-6P
ENF307-3T
ENF307-3B
—

ENF30E-4PB4
ENF30E-6PB6
—
—
—

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF60P-4PB6
ENF60P-6PB6
ENF60P-3TB8
ENF60P-3BB8
ENF60P-3MB6

ENF602-4PB6
ENF602-6PB6
ENF602-3TB8
ENF602-3BB8
ENF602-3MB6

ENF607-4P
ENF607-6P
ENF607-3T
ENF607-3B
—

ENF60E-4PB4
ENF60E-6PB6
—
—
—

4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF100P-4PB6
ENF100P-6PB6
ENF100P-3TB8
ENF100P-3BB8
ENF100P-3MB6

ENF1002-4PB6
ENF1002-6PB6
ENF1002-3TB8
ENF1002-3BB8
ENF1002-3MB6

ENF1007-4P
ENF1007-6P
ENF1007-3T
ENF1007-3B
—

ENF100E-4PB4
ENF100E-6PB6
—
—
—

2 Pole
4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF125P-2PB6
ENF125P-4PB6
ENF125P-6PB2
ENF125P-3TB8
—
ENF125P-3MB6

ENF1252-2PB6
ENF1252-4PB6
ENF1252-6PB2
ENF1252-3TB8
—
ENF1252-3MB6

ENF1257-2P
ENF1257-4P
ENF1257-6P
ENF1257-3T
—
—

—
—
—
—
—
—

2 Pole
4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF200P-2PB8
ENF200P-4PB8
ENF200P-6PB4
ENF200P-3TB4
ENF200P-3BB4
ENF200P-3MB8

ENF2002-2PB8
ENF2002-4PB8
ENF2002-6PB4
ENF2002-3TB4
ENF2002-3BB4
ENF2002-3MB8

ENF2007-2P
ENF2007-4P
ENF2007-6P
ENF2007-3T
ENF2007-3B
—

—
—
—
—
—
—

2 Pole
4 Pole
6 Pole
Transfer
Bypass
Mech. interlock

ENF400P-2PB4
ENF400P-4PB4
ENF400P-6P8
ENF400P-3TB4
ENF400P-3B6
ENF400P-3MB4

ENF4002-2PB4
ENF4002-4PB4
ENF4002-6P8
ENF4002-3TB4
ENF4002-3B6
ENF4002-3MB4

ENF4007-2P
ENF4007-4P
ENF4007-6P
ENF4007-3T
ENF4007-3B
—

—
—
—
—
—
—

For additional information and detail, see the Bussmann Disconnect Switch Catalog, Item Number 3006

120

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Disconnect Switches

Bussmann®

Fused, Dead Front, Disconnect Switches

15149 Series
Voltage Ratings: 600Vac, 30A
Agency Information:
UL Recognized, file E116716 for General Industrial
installations. Guide WFXV2.
CSA certified, file LR37129-6
• In 2 and 3 poles.
• Class J fuses.
• Fuse holders in the pull-out head eliminate possibility of
electric shock while changing fuse.
• Examined under the new proposed standard UL 1429
which imparts a stricter set of test conditions than the
former program that combined the applicable portions for
UL 512 (Fuse Holders) and UL 98 (Enclosed Switches).
Specifications
Voltage Rating

600V AC (maximum)

Current Rating

0 to 30A

Motor Rating

5 HP

Dielectric Withstand

2200V

Current Withstand

200,000 RMS Symmetrical Amperes

Ordering information:
15149 is available in 2 or 3 poles.
To order: Basic Part No. + number of poles.
Example: 15149-2 = 2-pole device.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 1141
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

121

Disconnect Switches

Bussmann®

Power Module™ —All-in-one Elevator Disconnect
Bussmann® Power Module™
(Fusible switch with shunt trip and fire safety
interface to allow for single point tie in with
fire alarm system.)

Complies with:
NFPA 70 (NEC®; National Electrical Code®)
ANSI/ASME A17.1 (Safety Code for Elevators
and Escalators)
NFPA 72 (National Fire Alarm Code®)
Features and Accessories:
• Shunt trip 120V
• Accepts LPJ-(amp)SP Class J fuses
• Control Power Transformer
• Fire Safety Interface Relay
• Key to Test Switch
• Pilot Light (on)
• Mechanically Interlocked Auxiliary Contact
• Neutral (200% Capability)
• Control Power Fuses and Blocks
• For added safety, use the Bussmann SAMI fuse
covers to improve maintenance personnel
protection (OSHA 1910.333, paragraph C).

Voltage Ratings:
600Vac, 3Ø Fused Power Switch
Short-Circuit Current Rating:
200,000A RMS

PS

PMP

Power Module™ Switch
(Single Elevator Applications)

Power Module™ Panel
(Multiple Elevator Applications)

Ampere Ratings:
30-400A

Ampere Ratings:
Feeder Switches - 30-400A
Main Switches2 - 400-800A

Agency Information:
UL Listed (UL 98) Enclosed and Dead front switch
Guide 96NK3917, File E182262
NEMA 1, UL 50 Listed enclosure1
ULc per Canadian Standards C22.2, No. 0-M91CAN/CSA C22.2, No. 4-M89 Enclosed switch.
1NEMA

12, 3R, and 4 enclosures also available

Data Sheet: 1145

122

Agency Information:
UL Listed (UL 67) Panel Boards or (UL 891)
Dead Front Switchboard, File E181664
ULc per Canadian Standards
Service Entrance Rated
2Contact

Bussmann for applications greater than 800A

Data Sheet: 1146
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

North American Style — General Information

Voltage Rating
130Vac/dc

1000 to 4000A

150Vac/dc

70 to 1000A

250Vac/dc

35 to 2500A

500Vac/dc

35 to 1600A

600Vac

1 to 1000A

700Vac/dc

5 to 1200A

800Vdc

35 to 600A

1000Vac, 700Vdc

35 to 2000A

All Bussmann North American Style fuses are certified for their
rated voltage.

Characteristics:
• Low energy let-thru (I2t)
• Low watts loss
• Superior cycling capability
• Low arc voltage
• Excellent dc performance
North American style fuses provide an excellent solution for
medium power applications. While there are currently no published standards for these fuses, the industry has standardized
on mounting centers that accept Bussmann fuses.
Accessories
Bussmann offers a comprehensive line of fuse bases that provide the user with design and manufacturing flexibility.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

123

Bussmann®

High Speed Fuses

North American Style
FWA 130V
Voltage Rating: 130Vac/130Vdc (130Vdc rating
applies to 1000 through 2000A only.)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, Std. 248-13
Watts loss provided at rated current.
Electrical Characteristics
Rated
Current
RMS-Amps

Ordering Information

I2t (A2 SEC) @ 100kA
Pre-arc

Clearing
at 130V

Watts
Loss

Part Number

Carton Qty.

Carton Weight (lbs)

1000

170000

460000

60.0

FWA-1000AH

1

3.3

1200

270000

730000

70.0

FWA-1200AH

1

3.3

1500

520000

1400000

78.0

FWA-1500AH

1

3.3

2000

860000

2400000

108.0

FWA-2000AH

1

3.3

2500

1500000

4100000

130.0

FWA-2500AH

1

3.3

3000

2100000

5700000

150.0

FWA-3000AH

1

3.3

4000

3400000

9200000

257.0

FWA-4000AH

1

3.3

Data Sheet: 720001

FWA 150V
Voltage Rating: 150Vac/150Vdc (150Vdc rating
applies to 70 through 800A only.)
Interrupting Rating: 100kA RMS Symmetrical. (70-400A)
200kA RMS Symmetrical. (450-1000A)
Agency Information: UL Recognized, Std. 248-13
Watts loss provided at rated current.
Electrical Characteristics
Rated
Current
RMS-Amps

Ordering Information

I2t (A2 SEC) @ 100kA
Pre-arc

Clearing
at 150V

Watts
Loss

Carton Qty.

Carton Weight (lbs)

70

470

4000

6.9

FWA-70B

10

1.76

80

670

6000

7.7

FWA-80B

10

1.76

100

1200

12000

9.0

FWA-100B

10

1.76

125

1870

18000

11.2

FWA-125B

10

1.76

150

2700

26000

13.5

FWA-150B

10

1.76

200

4780

45000

17.6

FWA-200B

10

1.76

250

7470

70000

22.5

FWA-250B

10

1.76

300

10760

100000

27.0

FWA-300B

10

1.76

350

15700

140000

30.6

FWA-350B

10

1.76

400

20300

180000

35.2

FWA-400B

10

1.76

500

39000

120000

35.0

FWA-500A

5

2.42

600

46000

140000

47.0

FWA-600A

5

2.42

700

75000

220000

49.0

FWA-700A

5

2.42

800

92000

280000

58.0

FWA-800A

5

2.42

1000

170000

510000

60.0

FWA-1000A

5

2.42

Part Number

CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann
Application Engineering at 636-527-1270 for more information.

Data Sheet: 720002

124

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

North American Style
FWX 250V
Voltage Rating: 250Vac/250Vdc (250Vdc rating on
35 through 800A only.)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information:
UL Recognized, Std. 248-13, 35-800A
Watts loss provided at rated current.

Electrical Characteristics
Rated
Current
RMS-Amps

Ordering Information

I2t (A2 SEC) @ 100kA
Pre-arc

Clearing
at 250V

Watts
Loss

Carton Qty.

Carton Weight (lbs)

35

50

230

4.2

FWX-35A

5

1.40

40

60

310

5.2

FWX-40A

5

1.40

45

80

390

5.7

FWX-45A

5

1.40

50

100

520

6.0

FWX-50A

5

1.40

60

140

740

8.1

FWX-60A

5

1.40

70

330

1400

7.2

FWX-70A

1

0.32

80

430

1850

8.1

FWX-80A

1

0.32

90

570

2450

9.0

FWX-90A

1

0.32

100

740

3150

10.0

FWX-100A

1

0.32

125

1130

4850

12.5

FWX-125A

1

0.32

150

1620

6950

15.7

FWX-150A

1

0.32

175

2170

9300

18.5

FWX-175A

1

0.32

200

2790

12000

22

FWX-200A

1

0.32

225

3210

14700

24

FWX-225A

1

0.52

250

3960

18100

27

FWX-250A

1

0.52

275

4720

21600

31

FWX-275A

1

0.52

300

6000

27300

32

FWX-300A

1

0.52

350

10600

48600

39

FWX-350A

1

0.52

400

14500

66100

44

FWX-400A

1

0.52

450

22100

101000

49

FWX-450A

1

0.52

500

28000

128000

54

FWX-500A

1

0.52

600

41100

188000

62

FWX-600A

1

0.52

700

48800

190000

72

FWX-700A

1

0.90

800

59000

230000

84

FWX-800A

1

0.90

1000

44000

360000

100

FWX-1000AH

1

2.86

1200

92000

750000

103

FWX-1200AH

1

2.86

1500

120000

880000

140

FWX-1500AH

1

2.86

1600

160000

1200000

140

FWX-1600AH

1

2.86

2000

320000

2300000

151

FWX-2000AH

1

2.86

2500

670000

4700000

163

FWX-2500AH

1

2.86

Part Number

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 720005
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

125

Bussmann®

High Speed Fuses

North American Style
FWH 500V
Voltage Rating: 500Vac/500Vdc (500Vdc rating applies
to 35 through 800A only.)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, Std. 248-13,
35-1200A; CSA Component Acceptance 35-1600A
Watts loss provided at rated current.

Electrical Characteristics
Rated
Current
RMS-Amps

Ordering Information

I2t (A2 SEC) @ 100kA
Pre-arc

Clearing
at 500V

Watts
Loss

Carton Qty.

Carton Weight (lbs)

35

34

150

.8

FWH- 35B

10

1.34

40

76

320

7.5

FWH-40B

10

1.34

45

105

450

7.5

FWH-45B

10

1.34

50

135

670

7.5

FWH-50B

10

1.34

60

210

900

9.9

FWH-60B

10

1.34

70

210

900

10.6

FWH-70B

10

2.05

80

305

1400

12.7

FWH-80B

10

2.05

90

360

1600

15

FWH-90B

10

2.05

100

475

2000

17

FWH-100B

10

2.05

125

800

3500

25

FWH-125B

5

1.65

150

1100

4600

30

FWH-150B

5

1.65

175

1450

6200

35

FWH-175B

5

1.65

200

1900

8500

40

FWH-200B

5

1.65

225

4600

23300

39

FWH-225A

1

0.57

250

6300

32200

41

FWH-250A

1

0.57

275

7900

40300

46

FWH-275A

1

0.57

300

9800

49800

51

FWH-300A

1

0.57

325

13700

63800

53

FWH-325A

1

0.57

350

14500

72900

58

FWH-350A

1

0.57

400

19200

96700

65

FWH-400A

1

0.57

450

24700

127000

74

FWH-450A

1

1.00

500

29200

149000

84

FWH-500A

1

1.00

600

41300

206000

108

FWH-600A

1

1.00

700

55000

298000

120

FWH-700A

1

2.14

800

76200

409000

129

FWH-800A

1

2.14

1000

92000

450000

145

FWH-1000A

1

4.62

1200

122000

600000

180

FWH-1200A

1

4.62

1400

200000

1000000

210

FWH-1400A

1

11.66

1600

290000

1400000

230

FWH-1600A

1

11.66

Part Number

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 720007

126

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

North American Style
KAC 600V

KBC 600V

Voltage Rating: 600Vac
Interrupting Rating: 200kA
RMS Symmetrical.
Agency Information:
UL Recognized, Std. 248-13,1-600A

Voltage Rating: 600Vac
Interrupting Rating: 200kA
RMS Symmetrical.
Agency Information:
UL Recognized, Std. 248-13,

• For new installations, Bussmann
recommends the 700V FWP series
fuse. The 600V fuses are
supplied as replacements only.

35-600A
• For new installations,
Bussmann recommends the
700 Volt FWP series fuse.
The 600V fuses are supplied
as replacements only.

Ordering Information
Part Number
KAC-1
KAC-2
KAC-3
KAC-4
KAC-5
KAC-6
KAC-7
KAC-8
KAC-9
KAC-10
KAC-12
KAC-15
KAC-17.5
KAC-20
KAC-25
KAC-30
KAC-35
KAC-40
KAC-45
KAC-50
KAC-60
KAC-70
KAC-80
KAC-90
KAC-100
KAC-110
KAC-125
KAC-150
KAC-175
KAC-200
KAC-225
KAC-250
KAC-300
KAC-350
KAC-400
KAC-450
KAC-500
KAC-600
KAC-700
KAC-800
KAC-1000

Carton Qty.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
5
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Carton Weight (lbs)
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
0.78
0.78
0.78
0.78
0.78
1.92
1.92
1.92
1.92
1.92
3.16
3.16
3.16
3.16
3.16
6.24

Ordering Information
Part Number
KBC-35
KBC-40
KBC-45
KBC-50
KBC-60
KBC-70
KBC-80
KBC-90
KBC-100
KBC-110
KBC-125
KBC-150
KBC-175
KBC-200
KBC-225
KBC-250
KBC-300
KBC-350
KBC-400
KBC-450
KBC-500
KBC-600
KBC-800

Carton Qty.
10
10
10
10
10
5
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Carton Weight (lbs)
1.40
1.40
1.40
1.40
1.40
1.44
1.44
1.44
1.44
0.48
0.48
0.48
0.48
0.48
0.77
0.77
0.77
0.77
0.77
1.32
1.32
1.32
4.50

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 720009
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 720010

127

Bussmann®

High Speed Fuses

North American Style
FWP 700V
Voltage Rating: 700Vac/700Vdc (700Vdc rating applies
to 5 through 800A only.)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, Std. 248-13;
CSA Component Acceptance
Watts loss provided at rated current.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics
Rated
Current
RMS-Amps

Ordering Information

I2t (A2 SEC) @ 100kA
Pre-arc

Clearing
at 700V

Watts
Loss

Carton Qty.

Carton Weight (lbs)

5

1.6

10

1.5

FWP-5B

10

2.25

10

3.6

20

4

FWP-10B

10

2.25

15

10

75

5.5

FWP-15B

10

2.25

20

26

180

6

FWP-20B

10

2.25

25

44

340

7

FWP-25B

10

2.25

30

58

450

9

FWP-30B

10

2.25

35

34

160

12

FWP-35B

10

2.42

40

76

320

12

FWP-40B

10

2.42

50

135

600

12

FWP-50B

10

2.42

60

210

950

15.5

FWP-60B

10

2.42

70

305

1400

18

FWP-70B

10

2.42

80

360

1600

21

FWP-80B

10

2.42

90

415

1900

25

FWP-90B

10

2.42

100

540

2500

27

FWP-100B

10

2.42

125

1800

7300

28

FWP-125A

1

0.65

150

2900

11700

32

FWP-150A

1

0.65

175

4200

16700

35

FWP-175A

1

0.65

200

5500

22000

43

FWP-200A

1

0.65

225

7700

31300

45

FWP-225A

1

1.17

250

10500

42500

48

FWP-250A

1

1.17

300

17600

71200

58

FWP-300A

1

1.17

350

23700

95600

65

FWP-350A

1

1.17

400

31000

125000

78

FWP-400A

1

1.17

450

36400

137000

94

FWP-450A

1

2.39

500

45200

170000

107

FWP-500A

1

2.39

600

66700

250000

122

FWP-600A

1

2.39

700

54000

300000

125

FWP-700A

1

1.21

800

78000

450000

140

FWP-800A

1

1.21

900

91500

530000

150

FWP-900A

1

6.60

1000

120000

600000

170

FWP-1000A

1

6.60

1200

195000

1100000

190

FWP-1200A

1

6.60

Part Number

Data Sheet: 720012

128

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

North American Style
FWJ 1000V
Voltage Rating: 1000Vac/800Vdc (Ampere ratings
35-200 and 500-600 rated up to 800Vdc)
Interrupting Rating: 25kA for 35-200A,
100kA for 250-600A
Agency Information:
UL Recognition on 35 through 600A only, Std. 248-13
Watts loss provided at rated current.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics
Rated
Current
RMS-Amps

Ordering Information

I2t (A2 SEC) @ 100kA
Pre-arc

Clearing
at 1000V

Watts
Loss

Carton Qty.

Carton Weight (lbs)

35

210

2000

7

FWJ-35A

10

4.18

40

300

2500

8

FWJ-40A

10

4.18

50

470

3500

10

FWJ-50A

10

4.18

60

670

5000

11

FWJ-60A

10

4.18

70

1100

6900

12

FWJ-70A

10

4.18

80

1550

9700

13

FWJ-80A

10

4.18

90

1900

12000

14

FWJ-90A

10

4.18

100

2800

17500

15

FWJ-100A

10

4.18

125

4800

35000

16

FWJ-125A

1

4.40

150

6300

45000

25

FWJ-150A

1

4.40

175

7500

65000

30

FWJ-175A

1

4.40

200

11700

80000

32

FWJ-200A

1

4.40

250

9000

50000

50

FWJ-250A

1

4.84

300

15000

80000

56

FWJ-300A

1

4.84

350

22000

120000

62

FWJ-350A

1

4.84

400

32000

180000

67

FWJ-400A

1

4.84

500

28500

155000

95

FWJ-500A

1

4.84

600

46500

260000

105

FWJ-600A

1

4.84

800

87000

500000

182

FWJ-800A

1

5.28

1000

190000

1100000

206

FWJ-1000A

1

5.28

1200

370000

2100000

240

FWJ-1200A

1

5.28

1400

470000

2700000

248

FWJ-1400A

1

5.28

1600

700000

4000000

267

FWJ-1600A

1

5.28

1800

925000

5300000

239

FWJ-1800A

1

5.28

2000

1330000

7600000

244

FWJ-2000A

1

5.28

Part Number

Data Sheet: 720027
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

129

Bussmann®

High Speed Fuses

North American Style Fuseblocks
Modular Style
Bussmann offers a comprehensive line of fuse bases that provide the user with design and manufacturing flexibility. Two
identical half bases make up a Buss Modular fuse base.
These “split” units can be panel mounted any distance
apart to accommodate any length fuse.
Stud Type
The simpler design is the C5268 Series Modular fuse
base. With this design, the fuse terminal and cable (with
termination) are mounted on the same stud, minimizing labor
needed for installation. The stud Type Base is available in the
configuration shown in the table below. (Must order 2 pieces
per fuse, they do not come in pairs.)
Part No.

Stud Heights

Stud Dia. & Threads

C5268-1

1.00∑

fiΩ¡§-18

C5268-2

1.75∑

fiΩ¡§-18

C5268-3

0.75∑

fiΩ¡§-18

C5268-4

1.00∑

⁄Ω¢-20

C5268-5

1.75∑

⁄Ω¢-20

Connector Type
Bussmann also offers a modular style fuse base that
utilizes a tin plated connector (for wire termination and heat
dissipation) and a plated steel stud (for fuse mounting). The
connector type fuse base is available in the configurations
shown below. Consult Bussmann for additional product
details. (Order 1 piece per fuse, parts come in pairs.)
Modular
Base Style

Max. Voltage

Max. Fuse
Current Rating

BH-0 Series

700V

100A

BH-1 Series

2500V

400A

BH-2 Series

5000V

400A

BH-3 Series

1250V

700A

See page 67.

Fixed Center Base Style
Bussmann offers a comprehensive line of fixed mount style fuse
bases under the trademark TRON Rectifier Fuseblocks. The
cable and fuse connections are similar to the Stud Type fuse
base — both are mounted on the same stud. Consult
Bussmann for complete product details.
®

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 720033

130

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body — General Information

Voltage Rating
690Vac
1250Vac

10 to 7500A
50 to 1400A

All Bussmann European Style fuses are tested to IEC 60269,
Part 4. This standard requires a test voltage which is 10%
higher than the rated voltage. In North America, fuses are
required to clear only their rated voltage.
Characteristics
Designed and tested to:
• IEC 60269: Part 4
• UL Recognized
• Minimal energy let-thru (I2t)
• Low operating temperature
• Low Watts loss

General Information
Each European Style fuse is available with a number of different end fittings. Options include:
• DIN 43 653
• North American Slotted Blade
• DIN 43 620
• Flush End (Metric/U.S.)
• French Style
Accessories
European Style fuses are available with three different open
fuse indicator systems. Options include visual indication and
indication utilizing a microswitch. Fuseblocks are also available
for most applications.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

131

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 653 —10-400A
Voltage Rating: 690V (IEC) & 700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information:
UL Recognized, Std. 248-13
CSA Component Acceptance on Size 000
Watts loss provided at rated current.
Microswitch indicator ordered separately.
See bottom of page 146.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Ordering Information

Watts
Loss

-U/80
Without
Indicator

-/80
Visual
Indicator

-TN/80
Type T
Indicator
for Micro

Carton
Qty.

Carton
Weight
(Kg)

I2t (A2s)
Size

000

00

Rated Current
RMS-Amps

Pre-arc

Clearing
at 660V

10

3.8

25.5

3.0

170M1308*

170M1358*

170M1408*

10

1.34

16

7.2

48

5.5

170M1309*

170M1359*

170M1409*

10

1.34

20

11.5

78

7

170M1310*

170M1360*

170M1410*

10

1.34

25

19

130

9

170M1311*

170M1361*

170M1411*

10

1.34

32

40

270

10

170M1312*

170M1362*

170M1412*

10

1.34

40

69

460

12

170M1313*

170M1363*

170M1413*

10

1.34

50

115

770

15

170M1314*

170M1364*

170M1414*

10

1.34

63

215

1450

16

170M1315*

170M1365*

170M1415*

10

1.34

80

380

2550

19

170M1316*

170M1366*

170M1416*

10

1.34

100

695

4650

24

170M1317*

170M1367*

170M1417*

10

1.34

125

1200

8500

28

170M1318*

170M1368*

170M1418*

10

1.34

160

2300

16000

32

170M1319*

170M1369*

170M1419*

10

1.34

200

4200

28000

37

170M1320*

170M1370*

170M1420*

10

1.34

250

7750

51500

42

170M1321*

170M1371*

170M1421*

10

1.34

315

12000

80500

52

170M1322*

170M1372*

170M1422*

10

1.34

25

19

130

6

—

170M2608

170M2658

5

1.05

32

28.5

195

7

—

170M2609

170M2659

5

1.05

40

50

360

9

—

170M2610

170M2660

5

1.05

50

95

640

10

—

170M2611

170M2661

5

1.05

63

170

1200

12

—

170M2612

170M2662

5

1.05

80

310

2100

15

—

170M2613

170M2663

5

1.05

100

620

4150

20

—

170M2614

170M2664

5

1.05

125

1000

6950

25

—

170M2615

170M2665

5

1.05

160

1900

13000

30

—

170M2616

170M2666

5

1.05

200

3400

23000

35

—

170M2617

170M2667

5

1.05

250

6250

42000

45

—

170M2618

170M2668

5

1.05

315

10000

68500

55

—

170M2619

170M2669

5

1.05

350

13500

91500

60

—

170M2620

170M2670

5

1.05

400

18000

125000

70

—

170M2621

170M2671

5

1.05

*UL Recognized / CSA Component Accepted on size 000.

Data Sheet: 720013

132

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 653 — 40-2000A
Voltage Rating: 690V (IEC) & 700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information

Watts
Loss

-/80
Visual
Indicator

-TN/80
Type T
Indicator
for Micro

-/110
Visual
Indicator

-TN/110
Type T
Indicator
for Micro

Carton
Qty.

Carton
Weight
(Kg)

9
11
14
18
21
26
30

170M3008*
170M3009*
170M3010*
170M3011*
170M3012*
170M3013*
170M3014*

170M3058*
170M3059*
170M3060*
170M3061*
170M3062*
170M3063*
170M3064*

170M3158*
170M3159*
170M3160*
170M3161*
170M3162*
170M3163*
170M3164*

170M3208*
170M3209*
170M3210*
170M3211*
170M3212*
170M3213*
170M3214*

5
5
5
5
5
5
5

1.50
1.50
1.50
1.50
1.50
1.50
1.50

35
40
50
55
60
65
70
75
80
45
55
58
60
65
70
72
75
80
85
95
100
65
70
75
80
90
95
105
110
115
120
130
95
100
105
110
115
120
125
130
140
155
160
160
165
175

170M3015*
170M3016*
170M3017*
170M3018*
170M3019*
170M3020*
170M3021*
170M3022*
170M3023*
170M4008*
170M4009*
170M4010*
170M4011*
170M4012*
170M4013*
170M4014*
170M4015*
170M4016*
170M4017*
170M4018*
170M4019
170M5008*
170M5009*
170M5010*
170M5011*
170M5012*
170M5013*
170M5014*
170M5015*
170M5016*
170M5017*
170M5018*
170M6008*
170M6009*
170M6010*
170M6011*
170M6012*
170M6013*
170M6014*
170M6015*
170M6016*
170M6017*
170M6018*
170M6019*
170M6020
170M6021

170M3065*
170M3066*
170M3067*
170M3068*
170M3069*
170M3070*
170M3071*
170M3072*
170M3073*
170M4058*
170M4059*
170M4060*
170M4061*
170M4062*
170M4063*
170M4064*
170M4065*
170M4066*
170M4067*
170M4068*
170M4069
170M5058*
170M5059*
170M5060*
170M5061*
170M5062*
170M5063*
170M5064*
170M5065*
170M5066*
170M5067*
170M5068*
170M6058*
170M6059*
170M6060*
170M6061*
170M6062*
170M6063*
170M6064*
170M6065*
170M6066*
170M6067*
170M6068*
170M6069*
170M6070
170M6071

170M3165*
170M3166*
170M3167*
170M3168*
170M3169*
170M3170*
170M3171*
170M3172*
170M3173*
170M4158*
170M4159*
170M4160*
170M4161*
170M4162*
170M4163*
170M4164*
170M4165*
170M4166*
170M4167*
170M4168*
170M4169
170M5158*
170M5159*
170M5160*
170M5161*
170M5162*
170M5163*
170M5164*
170M5165*
170M5166*
170M5167*
170M5168*
170M6158*
170M6159*
170M6160*
170M6161*
170M6162*
170M6163*
170M6164*
170M6165*
170M6166*
170M6167*
170M6168*
170M6169
170M6170
170M6171

170M3215*
170M3216*
170M3217*
170M3218*
170M3219*
170M3220*
170M3221*
170M3222*
170M3223*
170M4208*
170M4209*
170M4210*
170M4211*
170M4212*
170M4213*
170M4214*
170M4215*
170M4216*
170M4217*
170M4218*
170M4219
170M5208*
170M5209*
170M5210*
170M5211*
170M5212*
170M5213*
170M5214*
170M5215*
170M5216*
170M5217*
170M5218*
170M6208*
170M6209*
170M6210*
170M6211*
170M6212*
170M6213*
170M6214*
170M6215*
170M6216*
170M6217*
170M6218*
170M6219
170M6220
170M6221

5
5
5
5
5
5
5
5
5
3
(-/80)
—
2
(-/110)
—
—
—
—
—
—
—
2
2
2
2
2
2
2
2
2
2
2
2
(-/80)
—
1
(-/110)
—
—
—
—
—
—
—
—
—

1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.29
—
—
0.94
—
—
—
—
—
—
—
—
1.20
1.20
1.20
1.20
1.20
1.20
1.20
1.20
1.20
1.20
1.20
1.66
—
—
0.89
—
—
—
—
—
—
—
—
—
—

I2t (A2s)
Size

Rated Current
RMS-Amps
40
50
63
80
100
125
160

1*

1

2

3

*UL

Pre-arc

Clearing
at 660V

40
77
115
185
360
550
1100

270
515
770
1250
2450
3700
7500

200
2200
250
4200
315
7000
350
10000
400
15000
450
21000
500
27000
550
34000
630
48500
200
1650
250
3100
315
6200
350
8500
400
13500
450
17000
500
25000
550
34000
630
52000
700
69500
800
105000
‡900
155000
400
11000
450
15500
500
21500
550
28000
630
41000
700
60500
800
86000
900
125000
1000
180000
1100
245000
1250
365000
500
14000
550
19500
630
31000
700
44500
800
69500
900
100000
1000
140000
1100
190000
1250
290000
1400
370000
1500
460000
1600
580000
†1800
880000
‡2000
1150000
Recognized / CSA Component Accepted.

15000
28500
46500
68500
105000
140000
180000
230000
325000
11500
21000
42000
59000
91500
120000
170000
230000
350000
465000
725000
‡850000
74000
105000
145000
190000
275000
405000
575000
840000
1250000
1600000
2400000
95000
135000
210000
300000
465000
670000
945000
1300000
1950000
2450000
3100000
3900000
†5250000
‡6350000
Rated voltage †600V

‡550V

Data Sheet: 720014
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

133

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 653 — 40-2000A
Voltage Rating: 690V (IEC) & 700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information
Watts
Loss

-KN/80
Type K
Indicator
for Micro

-KN/110
Type K
Indicator
for Micro

Carton
Qty.

Carton
Weight (Kg)

9
11
14
18
21
26

170M3108*
170M3109*
170M3110*
170M3111*
170M3112*
170M3113*

170M3258*
170M3259*
170M3260*
170M3261*
170M3262*
170M3263*

5
5
5
5
5
5

1.60
1.60
1.60
1.60
1.60
1.60

30
35
40
50
55
60
65
70
75
80
45
55
58
60
65
70
72
75
80
85
95
100
65
70
75
80
90
95
105
110
115
120
130
95
100
105
110
115
120
125
130
140
155
160
160
165
175
‡550V

170M3114*
170M3115*
170M3116*
170M3117*
170M3118*
170M3119*
170M3120*
170M3121*
170M3122*
170M3123*
170M4108*
170M4109*
170M4110*
170M4111*
170M4112*
170M4113*
170M4114*
170M4115*
170M4116*
170M4117*
170M4118*
170M4119
170M5108*
170M5109*
170M5110*
170M5111*
170M5112*
170M5113*
170M5114*
170M5115*
170M5116*
170M5117*
170M5118*
170M6108*
170M6109*
170M6110*
170M6111*
170M6112*
170M6113*
170M6114*
170M6115*
170M6116*
170M6117*
170M6118*
170M6119*
170M6120
170M6121

170M3264*
170M3265*
170M3266*
170M3267*
170M3268*
170M3269*
170M3270*
170M3271*
170M3272*
170M3273*
170M4258*
170M4259*
170M4260*
170M4261*
170M4262*
170M4263*
170M4264*
170M4265*
170M4266*
170M4267*
170M4268*
170M4269
170M5258*
170M5259*
170M5260*
170M5261*
170M5262*
170M5263*
170M5264*
170M5265*
170M5266*
170M5267*
170M5268*
170M6258*
170M6259*
170M6260*
170M6261*
170M6262*
170M6263*
170M6264*
170M6265*
170M6266*
170M6267*
170M6268*
170M6269*
170M6270
170M6271

5
5
5
5
5
5
5
5
5
5
3
(-/80)
—
2
(-/110)
—
—
—
—
—
—
—
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1.60
1.60
1.60
1.60
1.60
1.60
1.60
1.60
1.60
1.60
1.38
—
—
1.00
—
—
—
—
—
—
—
—
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92

I2t (A2s)
Size

Rated Current
RMS-Amps
40
50
63
80
100
125

1*

1

2

3

*UL

160
200
250
315
350
400
450
500
550
630
200
250
315
350
400
450
500
550
630
700
800
‡900
400
450
500
550
630
700
800
900
1000
1100
1250
500
550
630
700
800
900
1000
1100
1250
1400
1500
1600
†1800
‡2000
Recognized / CSA Component

Pre-arc

Clearing
at 660V

40
77
115
185
360
550

270
515
770
1250
2450
3700

1100
2200
4200
7000
10000
15000
21000
27000
34000
48500
1650
3100
6200
8500
13500
17000
25000
34000
52000
69500
105000
155000
11000
15500
21500
28000
41000
60500
86000
125000
180000
245000
365000
14000
19500
31000
44500
69500
100000
140000
190000
290000
370000
460000
580000
880000
1150000
Accepted.

7500
15000
28500
46500
68500
105000
140000
180000
230000
325000
11500
21000
42000
59000
91500
120000
170000
230000
350000
465000
725000
‡850000
74000
105000
145000
190000
275000
405000
575000
840000
1250000
1600000
2400000
95000
135000
210000
300000
465000
670000
945000
1300000
1950000
2450000
3100000
3900000
†5250000
‡6350000
Rated voltage †600V

Data Sheet: 720015

134

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 653 — 50-1400A
Voltage Rating: 1250V (IEC)/1300V (UL)
Interrupting Rating: 100kA RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information
-/110
Visual
Indicator

-TN/110
Type T
Indicator
for Micro

Carton
Qty.

Carton
Weight (Kg)

15
20
25
30
35

170M3138*
170M3139*
170M3140*
170M3141*
170M3142*

170M3188*
170M3189*
170M3190*
170M3191*
170M3192*

5
5
5
5
5

1.90
1.90
1.90
1.90
1.90

40
45
55
60
65
70
45
50
60
65
70
75
80
85
95
100
65
70
75
80
85
90
95
100
110
115
120
125
135
85
90
95
100
105
110
115
120
125
130
135
140
145
150

170M3143*
170M3144*
170M3145*
170M3146*
170M3147*
170M3148*
170M4138*
170M4139*
170M4140*
170M4141*
170M4142*
170M4143*
170M4144*
170M4145*
170M4146*
170M4147
170M5138*
170M5139*
170M5140*
170M5141*
170M5142*
170M5143*
170M5144*
170M5145*
170M5146*
170M5147*
170M5148*
170M5149
170M5150
170M6138*
170M6139*
170M6140*
170M6141*
170M6142*
170M6143*
170M6144*
170M6145*
170M6146
170M6147
170M6148
170M6149
170M6150
170M6151

170M3193*
170M3194*
170M3195*
170M3196*
170M3197*
170M3198*
170M4188*
170M4189*
170M4190*
170M4191*
170M4192*
170M4193*
170M4194*
170M4195*
170M4196*
170M4197
170M5188*
170M5189*
170M5190*
170M5191*
170M5192*
170M5193*
170M5194*
170M5195*
170M5196*
170M5197*
170M5198*
170M5199
170M5200
170M6188*
170M6189*
170M6190*
170M6191*
170M6192*
170M6193*
170M6194*
170M6195*
170M6196*
170M6197*
170M6198*
170M6199*
170M6200
170M6201

5
5
5
5
5
5
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1.90
1.90
1.90
1.90
1.90
1.90
1.18
1.18
1.18
1.18
1.18
1.18
1.18
1.18
1.18
1.18
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.58
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23
1.23

I2t (A2s)
Size

Rated Current
RMS-Amps
50
63
80
100
125

1*

Pre-arc

Clearing
at 1000V

Clearing
at 1250V

135
215
420
750
1450

815
1300
2500
4450
9000

1100
1750
3350
5950
11500

160
2600
16000
200
5150
31000
250
9200
54500
315
18500
115000
350
27000
165000
400
53000
265000
160
1900
11500
200
3800
22500
250
7750
46000
315
15000
90000
1
350
20000
125000
400
29500
175000
450
42000
250000
500
69500
340000
550
95000
465000
†630
130000
660000
250
6500
38500
280
9350
55500
315
13000
77500
350
16500
97500
400
23000
140000
2
450
34000
205000
500
48000
285000
550
62000
370000
630
115000
575000
700
160000
795000
800
245000
1200000
†900
360000
1750000
†1000
480000
2350000
315
9500
58000
350
13500
81500
400
19500
120000
450
31000
185000
500
39000
235000
550
55000
325000
630
83500
495000
3
700
115000
705000
‡800
205000
995000
‡900
305000
1500000
‡1000
450000
2150000
‡1100
575000
2800000
†1250
810000
†3950000
†1400
1250000
†6000000
*UL Recognized / CSA Component Accepted. Rated voltage

Watts
Loss

21000
41000
73000
150000
220000
335000
15500
30000
61500
120000
165000
235000
335000
435000
590000
—
51500
74500
105000
135000
180000
270000
380000
495000
730000
1050000
1550000
—
—
77500
110000
160000
245000
310000
435000
665000
940000
1300000
1900000
2750000
3600000
—
—
†1100V ‡1250V

Data Sheet: 720029
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

135

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 653 — 50-1400A
Voltage Rating: 1250V (IEC)/1300V (UL)
Interrupting Rating: 100kA RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information
I2t (A2s)

Size

1*

1

2

3

Rated Current
RMS-Amps

Pre-arc

Clearing
at 1000V

Clearing
at 1250V

50
63
80
100
125
160

135
215
420
750
1450
2600

815
1300
2500
4450
9000
16000

1100
1750
3350
5950
11500
21000

200
250
315
350
400
160
200
250
315
350
400
450
500
550
†630
250
280
315
350
400
450
500
550
630
700
800
†900
†1000
315
350
400
450
500
550
630
700

5150
9200
18500
27000
53000
1900
3800
7750
15000
20000
29500
42000
69500
95000
130000
6500
9350
13000
16500
23000
34000
48000
62000
115000
160000
245000
360000
480000
9500
13500
19500
31000
39000
55000
83500
115000

31000
54500
115000
165000
265000
11500
22500
46000
90000
125000
175000
250000
340000
465000
660000
38500
55500
77500
97500
140000
205000
285000
370000
575000
795000
1200000
1750000
2350000
58000
81500
120000
185000
235000
325000
495000
705000

‡800
‡900
‡1000
‡1100

205000
995000
305000
1500000
450000
2150000
575000
2800000
†1250
810000
†3950000
†1400
1250000
†6000000
*UL Recognized / CSA Component Accepted. Rated voltage

Watts
Loss

-KN/110 Type K
Indicator for Micro

Carton
Qty.

Carton
Weight (Kg)

15
20
25
30
35
40

170M3238*
170M3239*
170M3240*
170M3241*
170M3242*
170M3243*

2
2
2
2
2
2

0.84
0.84
0.84
0.84
0.84
0.84

41000
73000
150000
220000
335000
15500
30000
61500
120000
165000
235000
335000
435000
590000
—
51500
74500
105000
135000
180000
270000
380000
495000
730000
1050000
1550000
—
—
77500
110000
160000
245000
310000
435000
665000
940000

45
55
60
65
70
45
50
60
65
70
75
80
85
95
100
65
70
75
80
85
90
95
100
110
115
120
125
135
85
90
95
100
105
110
115
120

1300000
1900000
2750000
3600000
—
—
†1100V

125
130
135
140
145
150

170M3244*
170M3245*
170M3246*
170M3247*
170M3248*
170M4238*
170M4239*
170M4240*
170M4241*
170M4242*
170M4243*
170M4244*
170M4245*
170M4246*
170M4247
170M5238*
170M5239*
170M5240*
170M5241*
170M5242*
170M5243*
170M5244*
170M5245*
170M5246*
170M5247*
170M5248*
170M5249
170M5250
170M6238*
170M6239*
170M6240*
170M6241*
170M6242*
170M6243*
170M6244*
170M6245*
170M6246
170M6247
170M6248
170M6249
170M6250
170M6251

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1

0.84
0.84
0.84
0.84
0.84
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.26
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.66
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27

‡1250V

Data Sheet: 720030

136

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 620 —10-315A
Voltage Rating: 690V (IEC/UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information:
UL Recognized, Std. 248-13
Rated Current: The rated current of this fuse range has
been given with copper conductors that have a current
density of 1.3 A/mm2 (IEC 60269-4). For conductor cross
section according to IEC 60269-1, the fuses with a rated
current higher than 125A must be derated. Please contact
Bussmann for application assistance.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Watts loss provided at rated current.
Microswitch indicator ordered separately.
See bottom of page 146.

Electrical Characteristics

Ordering Information
I2t (A2s)

Size

000

Rated Current
RMS-Amps

Pre-arc

Clearing
at 660V

Watts
Loss

DIN 000 Type T
Indicator for Micro

Carton
Qty.

Carton
Weight (Kg)

10

3.8

16

7.2

25.5

3.0

170M1558*

10

1.30

48

5.5

170M1559*

10

20

1.30

11.5

78

7

170M1560*

10

1.30

25

19

130

9

170M1561*

10

1.30

32

40

270

10

170M1562*

10

1.30

40

69

460

12

170M1563*

10

1.30

50

115

770

15

170M1564*

10

1.30

63

215

1450

16

170M1565*

10

1.30

80

380

2550

19

170M1566*

10

1.30

100

695

4650

24

170M1567*

10

1.30

125

1200

8500

28

170M1568*

10

1.30

160

2300

16000

32

170M1569*

10

1.30

200

4200

28000

37

170M1570*

10

1.30

250

7750

51500

42

170M1571*

10

1.30

315

12000

80500

52

170M1572*

10

1.30

*UL Recognized

Data Sheet: 720016
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

137

Bussmann®

High Speed Fuses

European Style Square Body
DIN 43 620 — 40-1000A
Voltage Rating: 690V (IEC)/700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information:
UL Recognized, Std. 248-13
Rated Current: The rated current of this fuse range has
been given with copper conductors that have a current
density of 1.3 A/mm2 (IEC 60269-4). For conductor cross
section according to IEC 60269-1, the fuses with a rated
current higher than 125A must be derated. Please contact
Bussmann for application assistance.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Watts loss provided at rated current.
Microswitch indicator ordered separately.
See bottom of page 146.

Electrical Characteristics

Ordering Information
I2t (A2s)

Size

Rated Current
RMS-Amps

1*

2

3

Pre-arc

Clearing
at 660V

40

40

270

50

77

515

63

115

770

80

185

100

Watts
Loss

DIN Type T
Indicator for Micro

Carton
Qty.

Carton
Weight (Kg)

9

170M3808*

5

1.85

11

170M3809*

5

1.85

14

170M3810*

5

1.85

1250

18

170M3811*

5

1.85

360

2450

21

170M3812*

5

1.85

125

550

3700

26

170M3813*

5

1.85

160

1100

7500

30

170M3814*

5

1.85

200

2200

15000

35

170M3815*

5

1.85

250

4200

28500

40

170M3816*

5

1.85

315

7000

46500

50

170M3817*

5

1.85

350

10000

68500

55

170M3818*

5

1.85

400

15000

105000

60

170M3819*

5

1.85

400

11000

74000

65

170M5808*

5

3.00

450

15500

105000

70

170M5809*

5

3.00

500

21500

145000

75

170M5810*

5

3.00

550

28000

190000

80

170M5811*

5

3.00

630

41000

275000

90

170M5812*

5

3.00

700

60500

405000

95

170M5813*

5

3.00

500

14000

95000

95

170M6808*

1

1.15

550

19500

135000

100

170M6809*

1

1.15

630

31000

210000

105

170M6810*

1

1.15

700

44500

300000

110

170M6811*

1

1.15

800

69500

465000

115

170M6812*

1

1.15

900

100000

670000

120

170M6813*

1

1.15

1000

140000

945000

125

170M6814*

1

1.15

*UL Recognized

Data Sheet: 720017

138

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
Flush End Contact 25-400A
Voltage Rating: 690V (IEC)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Watts loss provided at rated current.
Microswitch indicator ordered separately.
See bottom of page 146.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Ordering Information

Watts
Loss

00B/60
Visual
Indicator

00BTN/60
Type T
Indicator for
Microswitch

Carton
Qty.

Carton
Weight (Kg)

I t (A s)
2

Size

00

Rated Current
RMS-Amps

2

Pre-arc

Clearing
at 660V

25

19

130

6

170M2708

170M2758

5

1.35

32

28.5

195

7

170M2709

170M2759

5

1.35

40

50

360

9

170M2710

170M2760

5

1.35

50

95

640

10

170M2711

170M2761

5

1.35

63

170

1200

12

170M2712

170M2762

5

1.35

80

310

2100

15

170M2713

170M2763

5

1.35

100

620

4150

20

170M2714

170M2764

5

1.35

125

1000

6950

25

170M2715

170M2765

5

1.35

160

1900

13000

30

170M2716

170M2766

5

1.35

200

3400

23000

35

170M2717

170M2767

5

1.35

250

6250

42000

45

170M2718

170M2768

5

1.35

315

10000

68500

55

170M2719

170M2769

5

1.35

350

13500

91500

60

170M2720

170M2770

5

1.35

400

18000

125000

70

170M2721

170M2771

5

1.35

Data Sheet:720018
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

139

Bussmann®

High Speed Fuses

European Style Square Body
Flush End Contact 40-2000A
Voltage Rating: 690V (IEC) 700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information

Watts
Loss

-B/Visual
Indicator

-BKN/Type K
Indicator
for Micro

-G/Visual
Indicator

-GKN/Type K
Indicator
for Micro

Carton
Qty.

Carton
Weight
(Kg)

I t (A s)
2

Size

1*

1

2

Rated Current
RMS-Amps

2

Pre-arc

Clearing
at 660V

40
50
63
80
100
125
160

40
77
115
185
360
550
1100

270
515
770
1250
2450
3700
7500

9
11
14
18
21
26
30

170M3408*
170M3409*
170M3410*
170M3411*
170M3412*
170M3413*
170M3414*

170M3458*
170M3459*
170M3460*
170M3461*
170M3462*
170M3463*
170M3464*

170M3508*
170M3509*
170M3510*
170M3511*
170M3512*
170M3513*
170M3514*

170M3558*
170M3559*
170M3560*
170M3561*
170M3562*
170M3563*
170M3564*

10
(-B/-)
—
10
(-G/-)
—
6

2.40
—
—
2.40
—
—
1.62

200
250
315
350
400
450
500
550
630

2200
4200
7000
10000
15000
21000
27000
34000
48500

15000
28500
46500
68500
105000
140000
180000
230000
325000

35
40
50
55
60
65
70
75
80

170M3415*
170M3416*
170M3417*
170M3418*
170M3419*
170M3420*
170M3421*
170M3422*
170M3423*

170M3465*
170M3466*
170M3467*
170M3468*
170M3469*
170M3470*
170M3471*
170M3472*
170M3473*

170M3515*
170M3516*
170M3517*
170M3518*
170M3519*
170M3520*
170M3521*
170M3522*
170M3523*

170M3565*
170M3566*
170M3567*
170M3568*
170M3569*
170M3570*
170M3571*
170M3572*
170M3573*

(-BKN/-)
—
—
6
(-GKN/-)
—
—
—
—

—
—
—
1.62
—
—
—
—
—

200
250
315
350
400
450
500
550
630
700
800
‡900

1650
3100
6200
8500
13500
17000
25000
34000
52000
69500
105000
155000

11500
21000
42000
59000
91500
120000
170000
230000
350000
465000
725000
‡850000

45
55
58
60
65
70
72
75
80
85
95
100

170M4408*
170M4409*
170M4410*
170M4411*
170M4412*
170M4413*
170M4414*
170M4415*
170M4416*
170M4417*
170M4418*
170M4419

170M4458*
170M4459*
170M4460*
170M4461*
170M4462*
170M4463*
170M4464*
170M4465*
170M4466*
170M4467*
170M4468*
170M4469

170M4508*
170M4509*
170M4510*
170M4511*
170M4512*
170M4513*
170M4514*
170M4515*
170M4516*
170M4517*
170M4518*
170M4519

170M4558*
170M4559*
170M4560*
170M4561*
170M4562*
170M4563*
170M4564*
170M4565*
170M4566*
170M4567*
170M4568*
170M4569

6
6
6
6
6
6
6
6
6
6
6
6

2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.40

400
450
500
550
630
700
800
900
1000
1100
1250

11000
15500
21500
28000
41000
60500
86000
125000
180000
245000
365000

74000
105000
145000
190000
275000
405000
575000
840000
1250000
1600000
2400000

65
70
75
80
90
95
105
110
115
120
130

170M5408*
170M5409*
170M5410*
170M5411*
170M5412*
170M5413*
170M5414*
170M5415*
170M5416*
170M5417*
170M5418*

170M5458*
170M5459*
170M5460*
170M5461*
170M5462*
170M5463*
170M5464*
170M5465*
170M5466*
170M5467*
170M5468*

170M5508*
170M5509*
170M5510*
170M5511*
170M5512*
170M5513*
170M5514*
170M5515*
170M5516*
170M5517*
170M5518*

170M5558*
170M5559*
170M5560*
170M5561*
170M5562*
170M5563*
170M5564*
170M5565*
170M5566*
170M5567*
170M5568*

6
6
6
6
6
6
6
6
6
4
4

3.30
3.30
3.30
3.30
3.30
3.30
3.30
3.30
3.30
2.40
2.40

95
100
105
110
115
120
125
130
140
155
160
160
165
175

170M6408*
170M6409*
170M6410*
170M6411*
170M6412*
170M6413*
170M6414*
170M6415*
170M6416*
170M6417*
170M6418*
170M6419*
170M6420
170M6421

170M6458*
170M6459*
170M6460*
170M6461*
170M6462*
170M6463*
170M6464*
170M6465*
170M6466*
170M6467*
170M6468*
170M6469*
170M6470
170M6471

170M6508*
170M6509*
170M6510*
170M6511*
170M6512*
170M6513*
170M6514*
170M6515*
170M6516*
170M6517*
170M6518*
170M6519*
170M6520
170M6521

170M6558*
170M6559*
170M6560*
170M6561*
170M6562*
170M6563*
170M6564*
170M6565*
170M6566*
170M6567*
170M6568*
170M6569*
170M6570
170M6571

3
3
3
3
3
3
3
3
3
3
3
2
2
2

2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
2.52
1.82
1.82
1.82

500
14000
550
19500
630
31000
700
44500
800
69500
900
100000
3
1000
140000
1100
190000
1250
290000
1400
370000
1500
460000
1600
580000
†1800
880000
‡2000
1150000
*UL Recognized / CSA Component Accepted.

95000
135000
210000
300000
465000
670000
945000
1300000
1950000
2450000
3100000
3900000
†5250000
‡6350000
Rated voltage †600V ‡550V

Data Sheet: 720019

140

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
Flush End Contact —1000-4000A
Voltage Rating: 690V (IEC)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information: UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately.
See bottom of page 146.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Size

4

Rated
Current
RMSNorm
Cool.

Rated
Current
RMSLiquid
Cool.

1000

1350

1250

1700

1400

1900

1600

Ordering Information

-G/Visual
Indicator

-GKN/Type K
Indicator
for Micro

170M7058 170M7078

170M7098

170M7118

170M7059 170M7079

170M7099

170M7119

2

1.80

375

170M7060 170M7080

170M7100

170M7120

2

1.80

220

405

170M7061 170M7081

170M7101

170M7121

2

1.80

3950000

245

445

170M7062 170M7082

170M7102

170M7122

2

1.80

1200000

7800000

275

495

170M7063 170M7083

170M7103

170M7123

2

1.80

4100

2000000

13500000

305

555

170M7064 170M7084

170M7104

170M7124

2

1.80

3500

4700

3250000

22000000

325

585

170M7065 170M7085

170M7105

170M7125

2

1.80

†4000

†5400

4700000

†28000000

355

640

170M7066 170M7086

170M7106

170M7126

2

1.80

Pre-arc

Clearing
at 660V

Watts
Loss
Norm.
Cool.

Watts
Loss
Liquid
Cool.

76000

505000

175

315

145000

965000

195

355

205000

1400000

205

2200

305000

2050000

2000

2700

600000

2500

3400

3000

I2t (A2s)

-B/Visual
Indicator

-BKN/Type K
Indicator
for Micro

Carton
Qty.
2

Carton
Weight
(Kg)
1.80

Rated voltage †500V.
Liq. Cool. - Liquid cooling. Temperature on the terminals not to exceed 60°C.

Data Sheet: 720020
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

141

Bussmann®

High Speed Fuses

European Style Square Body
Flush End Contact — 50-1400A
Voltage Rating: 1250V (IEC) 1300V (UL)
Interrupting Rating: 100kA RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information
I2t (A2s)

Size

Rated Current
RMS-Amps
50
63
80
100
125

1*

Pre-arc

Clearing
at 1000V

Clearing
at 1250V

135
215
420
750
1450

815
1300
2500
4450
9000

1100
1750
3350
5950
11500

160
2600
200
5150
250
9200
315
18500
350
27000
400
53000
160
1900
200
3800
250
7750
315
15000
1
350
20000
400
29500
450
42000
500
69500
550
95000
630
130000
250
6500
280
9350
315
13000
350
16500
400
23000
2
450
34000
500
48000
550
62000
630
115000
700
160000
800
245000
†900
360000
†1000
480000
315
9500
350
13500
400
19500
450
31000
500
39000
550
55000
630
83500
3
700
115000
800
205000
900
305000
1000
450000
1100
575000
†1250
810000
†1400
1250000
*UL Recognized / CSA Component Accepted.
Individual Fuse Weight: Size 1* = 0.380 Kg
Size 1 = 0.580 Kg
Size 2 = 0.900 Kg
Size 3 = 1.250 Kg

16000
31000
54500
115000
165000
265000
11500
22500
46000
90000
125000
175000
250000
340000
465000
660000
38500
55500
77500
97500
140000
205000
285000
370000
575000
795000
1200000
1750000
2350000
58000
81500
120000
185000
235000
325000
495000
705000
995000
1500000
2150000
2800000
3950000
6000000
Rated voltage

Watts
Loss
15
20
25
30
35

21000
40
41000
45
73000
55
150000
60
220000
65
335000
70
15500
45
30000
50
61500
60
120000
65
165000
70
235000
75
335000
80
435000
85
590000
95
—
100
51500
65
74500
70
105000
75
135000
80
180000
85
270000
90
380000
95
495000
100
730000
110
1050000
115
1550000
120
—
125
—
135
77500
85
110000
90
160000
95
245000
100
310000
105
435000
110
665000
115
940000
120
1300000
125
1900000
130
2750000
135
3600000
140
—
145
—
150
†1100
‡1000V ¥1250V

-BKN/75
Type K
Indicator
for Micro

-BKN/80
Type K
Indicator
for Micro

-BKN/90
Type K
Indicator
for Micro

-GKN/75
Type K
Indicator
for Micro

-GKN/90
Type K
Indicator
for Micro

170M3388*
170M3389*
170M3390*
170M3391*
170M3392*

170M3438*
170M3439*
170M3440*
170M3441*
170M3442*

—
—
—
—
—

170M3488*
170M3489*
170M3490*
170M3491*
170M3492*

—
—
—
—
—

170M3393*
170M3394*
170M3395*
170M3396*
170M3397*
—
170M4388*
170M4389*
170M4390*
170M4391*
170M4392*
170M4393*
170M4394*
†170M4395
‡170M4396
‡170M4397
170M5388*
170M5389*
170M5390*
170M5391*
170M5392*
170M5393*
170M5394*
170M5395*
†170M5396
‡170M5397
‡170M5398
—
—
170M6338*
170M6339*
170M6340*
170M6341*
170M6342*
170M6343*
170M6344*
170M6345*
†170M6346
‡170M6347
‡170M6348
‡170M6349
—
—

170M3443*
170M3444*
170M3445*
170M3446*
170M3447*
170M3448*
170M4438*
170M4439*
170M4440*
170M4441*
170M4442*
170M4443*
170M4444*
170M4445*
170M4446*
†170M4447
170M5438*
170M5439*
170M5440*
170M5441*
170M5442*
170M5443*
170M5444*
170M5445*
170M5446*
†170M5447
‡170M5448
—
—
170M6538*
170M6539*
170M6540*
170M6541*
170M6542*
170M6543*
170M6544*
170M6545*
170M6546*
†170M6547
†170M6548
‡170M6549
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
170M5494*
170M5495*
170M5496*
170M5497*
170M5498*
170M5499
170M5500
—
—
—
—
—
—
170M6494*
170M6495*
¥170M6496
¥170M6497
¥170M6498
¥170M6499
170M6500
170M6501

170M3493*
170M3494*
170M3495*
170M3496*
170M3497*
—
170M4488*
170M4489*
170M4490*
170M4491*
170M4492*
170M4493*
170M4494*
†170M4495
‡170M4496
‡170M4497
170M5588*
170M5589*
170M5590*
170M5591*
170M5592*
170M5593*
170M5594*
170M5595*
†170M5596
‡170M5597
‡170M5598
—
—
170M6588*
170M6589*
170M6590*
170M6591*
170M6592*
170M6593*
170M6594*
170M6595*
†170M6596
‡170M6597
‡170M6598
‡170M6599
—
—

1 kg = 2.2 lbs. 1 lb = 0.45 kg

Data Sheet: 720031

142

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
170M5644*
170M5645*
170M5646*
170M5647*
170M5648*
170M5649
170M5650
—
—
—
—
—
—
170M6644*
170M6645*
¥170M6646
¥170M6647
¥170M6648
¥170M6649
170M6650
170M6651

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
French Standard — 40-1500A
Voltage Rating: 690V (IEC), 700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information

Watts
Loss

-E/
Type T
Indicator
for Micro

-EKN/
Type K
Indicator
for Micro

Carton
Qty.

Carton
Weight (Kg)

I2t (A2s)
Size

1*

1

2

3

Rated Current
RMS-Amps

Pre-arc

Clearing
at 660V

40
50
63
80
100

40
77
115
185
360

270
515
770
1250
2450

9
11
14
18
21

170M3308*
170M3309*
170M3310*
170M3311*
170M3312*

170M3358*
170M3359*
170M3360*
170M3361*
170M3362*

1
1
1
1
1

0.300
0.300
0.300
0.300
0.300

125
160

550
1100

3700
7500

26
30

200
250
315
350
400
450
500
200
250
315
350
400
450
500
550
630
700
800
400
450
500
550
630
700
800
900
1000
500
550
630
700
800
900
1000
1100
1250
1400
1500

2200
4200
7000
10000
15000
21000
27000
1650
3100
6200
8500
13500
17000
25000
34000
52000
69500
105000
11000
15500
21500
28000
41000
60500
86000
125000
180000
14000
19500
31000
44500
69500
100000
140000
190000
290000
370000
460000

15000
28500
46500
68500
105000
140000
180000
11500
21000
42000
59000
91500
120000
170000
230000
350000
465000
725000
74000
105000
145000
190000
275000
405000
575000
840000
1250000
95000
135000
210000
300000
465000
670000
945000
1300000
1950000
2450000
3100000

35
40
50
55
60
65
70
45
55
58
60
65
70
72
75
80
85
95
65
70
75
80
90
95
105
110
115
95
100
105
110
115
120
125
130
140
155
160

170M3313*
170M3314*
170M3315*
170M3316*
170M331z7*
170M3318*
170M3319*
170M3320*
170M3321*
170M4308*
170M4309*
170M4310*
170M4311*
170M4312*
170M4313*
170M4314*
170M4315*
170M4316*
170M4317*
170M4318*
170M5308*
170M5309*
170M5310*
170M5311*
170M5312*
170M5313*
170M5314*
170M5315*
170M5316*
170M6308*
170M6309*
170M6310*
170M6311*
170M6312*
170M6313*
170M6314*
170M6315*
170M6316*
170M6317*
170M6318*

170M3363*
170M3364*
170M3365*
170M3366*
170M3367*
170M3368*
170M3369*
170M3370*
170M3371*
170M4358*
170M4359*
170M4360*
170M4361*
170M4362*
170M4363*
170M4364*
170M4365*
170M4366*
170M4367*
170M4368*
170M5358*
170M5359*
170M5360*
170M5361*
170M5362*
170M5363*
170M5364*
170M5365*
170M5366*
170M6358*
170M6359*
170M6360*
170M6361*
170M6362*
170M6363*
170M6364*
170M6365*
170M6366*
170M6367*
170M6368*

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.300
0.470
0.470
0.470
0.470
0.470
0.470
0.470
0.470
0.470
0.470
0.470
0.620
0.620
0.620
0.620
0.620
0.620
0.620
0.620
0.620
0.930
0.930
0.930
0.930
0.930
0.930
0.930
0.930
0.930
0.930
0.930

*UL Recognized / CSA Component Accepted.

Data Sheet: 720022
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

143

Bussmann®

High Speed Fuses

European Style Square Body
US Standard — 40-2000A
Voltage Rating: 690V (IEC), 700V (UL)
Interrupting Rating: 200kA (estimated 300kA) RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information
-FU/Without
Indicator

-FKE/Type K
Indicator
for Micro

-FU/115
Without
Indicator

-FKE/115
Type K
Indicator
for Micro

Carton
Qty.

Carton
Weight
(Kg)

9
11
14
18
21
26
30

170M3608*
170M3609*
170M3610*
170M3611*
170M3612*
170M3613*
170M3614*

170M3658*
170M3659*
170M3660*
170M3661*
170M3662*
170M3663*
170M3664*

170M3708*
170M3709*
170M3710*
170M3711*
170M3712*
170M3713*
170M3714*

170M3758*
170M3759*
170M3760*
170M3761*
170M3762*
170M3763*
170M3764*

1
1
1
1
1
1
1

0.340
0.340
0.340
0.340
0.340
0.340
0.340

35
40
50
55
60
65
70
75
80
45
55
58
60
65
70
72
75
80
85
95
100
65
70
75
80
90
95
105
110
115
120
130
95
100
105
110
115
120
125
130
140
155
160
160
165
175

170M3615*
170M3616*
170M3617*
170M3618*
170M3619*
170M3620*
170M3621*
170M3622*
170M3623*
170M4608*
170M4609*
170M4610*
170M4611*
170M4612*
170M4613*
170M4614*
170M4615*
170M4616*
170M4617*
170M4618*
170M4619
170M5608*
170M5609*
170M5610*
170M5611*
170M5612*
170M5613*
170M5614*
170M5615*
170M5616*
170M5617*
170M5618*
170M6608*
170M6609*
170M6610*
170M6611*
170M6612*
170M6613*
170M6614*
170M6615*
170M6616*
170M6617*
170M6618*
170M6619*
170M6620
170M6621

170M3665*
170M3666*
170M3667*
170M3668*
170M3669*
170M3670*
170M3671*
170M3672*
170M3673*
170M4658*
170M4659*
170M4660*
170M4661*
170M4662*
170M4663*
170M4664*
170M4665*
170M4666*
170M4667*
170M4668*
170M4669
170M5658*
170M5659*
170M5660*
170M5661*
170M5662*
170M5663*
170M5664*
170M5665*
170M5666*
170M5667*
170M5668*
170M6658*
170M6659*
170M6660*
170M6661*
170M6662*
170M6663*
170M6664*
170M6665*
170M6666*
170M6667*
170M6668*
170M6669*
170M6670
170M6671

170M3715*
170M3716*
170M3717*
170M3718*
170M3719*
170M3720*
170M3721*
170M3722*
170M3723*
170M4708*
170M4709*
170M4710*
170M4711*
170M4712*
170M4713*
170M4714*
170M4715*
170M4716*
170M4717*
170M4718*
170M4719
170M5708*
170M5709*
170M5710*
170M5711*
170M5712*
170M5713*
170M5714*
170M5715*
170M5716*
170M5717*
170M5718*
170M6708*
170M6709*
170M6710*
170M6711*
170M6712*
170M6713*
170M6714*
170M6715*
170M6716*
170M6717*
170M6718*
170M6719*
170M6720
170M6721

170M3765*
170M3766*
170M3767*
170M3768*
170M3769*
170M3770*
170M3771*
170M3772*
170M3773*
170M4758*
170M4759*
170M4760*
170M4761*
170M4762*
170M4763*
170M4764*
170M4765*
170M4766*
170M4767*
170M4768*
170M4769
170M5758*
170M5759*
170M5760*
170M5761*
170M5762*
170M5763*
170M5764*
170M5765*
170M5766*
170M5767*
170M5768*
170M6758*
170M6759*
170M6760*
170M6761*
170M6762*
170M6763*
170M6764*
170M6765*
170M6766*
170M6767*
170M6768*
170M6769*
170M6770
170M6771

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

0.340
0.340
0.340
0.340
0.340
0.340
0.340
0.340
0.340
0.500
0.500
0.500
0.500
0.500
0.500
0.500
0.500
0.500
0.500
0.500
0.500
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.630
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950
0.950

I t (A s)
2

Size

Rated Current
RMS-Amps
40
50
63
80
100
125
160

2

Pre-arc

Clearing
at 660V

40
77
115
185
360
550
1100

270
515
770
1250
2450
3700
7500

200
2200
15000
250
4200
28500
315
7000
46500
350
10000
68500
400
15000
105000
450
21000
140000
500
27000
180000
550
34000
230000
630
48500
325000
200
1650
11500
250
3100
21000
315
6200
42000
350
8500
59000
400
13500
91500
450
17000
120000
1
500
25000
170000
550
34000
230000
630
52000
350000
700
69500
465000
800
105000
725000
‡900
155000
‡850000
400
11000
74000
450
15500
105000
500
21500
145000
550
28000
190000
630
41000
275000
2
700
60500
405000
800
86000
575000
900
125000
840000
1000
180000
1250000
1100
245000
1600000
1250
365000
2400000
500
14000
95000
550
19500
135000
630
31000
210000
700
44500
300000
800
69500
465000
900
100000
670000
1000
140000
945000
3
1100
190000
1300000
1250
290000
1950000
1400
370000
2450000
1500
460000
3100000
1600
580000
3900000
†1800
880000
†5250000
‡2000
1150000
‡6350000
*UL Recognized / CSA Component Accepted. Rated voltage †600V ‡550V
1*

Watts
Loss

Data Sheet: 720023

144

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

European Style Square Body
US Standard — 50-1400A
Voltage Rating: 1250V (IEC), 1300V (UL)
Interrupting Rating: 100kA RMS Symmetrical
Agency Information: CSA Component Acceptance
UL Recognized, Std. 248-13
Watts loss provided at rated current.
Microswitch indicator ordered separately. See bottom of page 146.
Electrical Characteristics

Ordering Information
I2t (A2s)

Size

1*

Rated Current
RMS-Amps
50
63
80
100
125
160

Pre-arc

Clearing
at 1000V

Clearing
at 1250V

135
215
420
750
1450
2600

815
1300
2500
4450
9000
16000

1100
1750
3350
5950
11500
21000

200
5150
31000
250
9200
54500
315
18500
115000
350
27000
165000
160
1900
11500
200
3800
22500
250
7750
46000
315
15000
90000
350
20000
125000
1
400
29500
175000
450
42000
250000
†500
69500
340000
†550
95000
465000
‡630
130000
660000
250
6500
38500
280
9350
55500
315
13000
77500
350
16500
97500
400
23000
140000
450
34000
205000
2
500
48000
285000
550
62000
370000
630
115000
575000
†700
160000
795000
†800
245000
1200000
†900
360000
1750000
‡1000
480000
2350000
315
9500
58000
350
13500
81500
400
19500
120000
450
31000
185000
500
39000
235000
550
55000
325000
630
83500
495000
3
700
115000
705000
800
205000
995000
900
305000
1500000
¥1000
450000
2150000
¥1100
575000
2800000
¥1250
810000
3950000
¥1400
1250000
6000000
*UL Recognized / CSA Component Accepted. Rated voltage
¥ UL Recognized / CSA Component Accepted at 1000V

41000
73000
150000
220000
15500
30000
61500
120000
165000
235000
335000
435000
590000
—
51500
74500
105000
135000
180000
270000
380000
495000
730000
1050000
1550000
—
—
77500
110000
160000
245000
310000
435000
665000
940000
1300000
1900000
2750000
3600000
—
—
†1100V ‡1000V

Watts
Loss
15
20
25
30
35
40
45
55
60
65
45
50
60
65
70
75
80
85
95
100
65
70
75
80
85
90
95
100
110
115
120
125
135
185
90
95
100
105
110
115
120
125
130
135
140
145
150

-FU/115
Without
Indicator

-FKE/115
Type K
Indicator
for Micro

Carton
Qty.

Carton
Weight (Kg)

170M3688*
170M3689*
170M3690*
170M3691*
170M3692*

170M3738*
170M3739*
170M3740*
170M3741*
170M3742*

1
1
1
1
1

0.425
0.425
0.425
0.425
0.425

170M3693*
170M3694*
170M3695*
170M3696*
170M3697*
170M4688*
170M4689*
170M4690*
170M4691*
170M4692*
170M4693*
170M4694*
170M4695
170M4696
170M4697
170M5688*
170M5689*
170M5690*
170M5691*
170M5692*
170M5693*
170M5694*
170M5695*
170M5696*
170M5697
170M5698
170M5699
170M5700
170M6688*
170M6689*
170M6690*
170M6691*
170M6692*
170M6693*
170M6694*
170M6695*
170M6696*
170M6697*
†170M6698*
†170M6699*
‡170M6700*
‡170M6701*

170M3743*
170M3744*
170M3745*
170M3746*
170M3747*
170M4738*
170M4739*
170M4740*
170M4741*
170M4742*
170M4743*
170M4744*
170M4745
170M4746
170M4747
170M5738*
170M5739*
170M5740*
170M5741*
170M5742*
170M5743*
170M5744*
170M5745*
170M5746*
170M5747
170M5748
170M5749
170M5750
170M6738*
170M6739*
170M6740*
170M6741*
170M6742*
170M6743*
170M6744*
170M6745*
170M6746*
170M6747*
†170M6748*
†170M6749*
‡170M6750*
‡170M6751*

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

0.425
0.425
0.425
0.425
0.425
0.675
0.675
0.675
0.675
0.675
0.675
0.675
0.675
0.675
0.675
0.740
0.740
0.740
0.740
0.740
0.740
0.740
0.740
0.740
0.740
0.740
0.740
0.740
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250
1.250

Data Sheet: 720032
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

145

Bussmann®

High Speed Fuses

Indicator System
Indicators
Typower ZILOX fuses are available with three different indicator systems.
Visual Indicator
The indicator situated in one cover plate is clearly visible as
soon as the fuse has operated. The minimum voltage for
operating the indicator is 20V.
Type T Indicator
The indicator is situated on one cover plate with a cover
plate tag to accommodate an auxiliary switch. The minimum
voltage for operating the indicator is 20V. A special low voltage indicator (1.5V) is available on request.
Type K Indicator
This indicator is situated on the fuse body. It is covered by
an adaptor for snap-on mounting of an auxiliary switch. The
operating voltage of the indicator is 1.5V. As a matter of
safety, the factory mounted adaptor must not be removed
from the fuse.

Microswitch
The Typower ZILOX fuses with either type T indicator or
type K indicator can be equipped with a microswitch for
remote electrical indication of fuse operations. All microswitches have one normally open and one normally closed
contact. Ratings are 2A, 250Vac.

Microswitch
170H0235
170H0236
170H0237
170H0238
170H0069

6.3 x 0.8 mm
Lugs
≈
≈

≈
≈

000
00
1*
1
2
3

Indicator
Type
T
T
T
T

K

≈

DIN 43 653
Size

2.8 x 0.5 mm
Lugs

Type T
170H0236
170H0238
170H0235
170H0237
170H0235
170H0237
170H0235
170H0237
170H0235
170H0237
170H0235
170H0237

4
23
24

Type K

DIN 43 620
Type T
170H0236
170H0238

Type K

French Style
Type T

Type K

Flush End
Type T

US Style

Type K

Type K

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0069

170H0235
170H0237
170H0069

170H0235
170H0237

170H0069
170H0069
170H0069

170H0235
170H0237
170H0236
170H0238

170H0236
170H0238
170H0236
170H0238
170H0236
170H0238
170H0236
170H0238

170H0069
170H0069
170H0069

Data Sheet: 720034

146

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

Fuse Bases (Blocks)
DIN 43 653 Fuse Bases
For the Typower ZILOX fuses according to DIN 43 653, the
following fuse bases are available:
Part
Number
170H3003
170H3004
170H3005
170H3006

Max.
Voltage
1000V
1000V
1400V
1400V

Rated
Current
630A
1250A
630A
1250A

170H3003

Center
Distance
80mm
80mm
110mm
110mm

The fuse bases rated 1250A can also be used for the fuses
with higher rated current if the maximum load current is
derated according to the table below:
Fuse Rating
1400A
1500A
1600A
1800A
2000A

Max. Load Current In Fuse Base
1325A
1400A
1500A
1650A
1800A

Fixed Center
Base Style
Max. Voltage
170H1007*
1000V
170H1013*
660V
*UL Recognized to UL 512.

Max. Fuse
Current Rating
400A
200A

170H1007

Fuse
Size
00, 000
0000,000

Universal Fuse Bases
For the Typower ZILOX fuses according to DIN 43 653,
French style and North American style, the following fuse
bases are available:
Modular
Base Style
1BS101
1BS102
1BS103
1BS104
BH-0XXX
BH-1XXX
BH-2XXX
BH-3XXX

Max. Voltage
600V
600V
600V
600V
700V
2500V
5000V
1250V

Max. Fuse
Current Rating
100A
400A
400A
600A
100A
400A
400A
700A

BIF
Document
1206
1207
1208
1209
1200
1201
1202
1203

1BS104

Universal fuse bases are UL Recognized to UL 512 and meet
the spacing requirements of UL 347. Contact Bussmann
sales representative for more complete ordering information.
DIN 43 620 Fuse Bases
For fuse bases used with Typower ZILOX fuses according to
DIN 43 620, please contact your local Bussmann sales
representative.

Data Sheet: 720036
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

147

Bussmann®

High Speed Fuses

British Standard BS88: Part 4
Voltage Rating
240Vac/150Vdc

6 to 900A

690Vac/450Vdc

6 to 700A

All Bussmann British Style fuses are tested to IEC 269: Part
4. This standard requires a test voltage which is 10% higher
than the rated voltage. In North America, fuses are required
to clear only their rated voltage.
Designed and tested to:
• BS 88: Part 4
• IEC 60269: Part 4
• UL Recognized, Std. 248-13
Bussmann British Style products use innovative arc quenching techniques and high grade materials to provide:
• Minimal energy let-thru (I2t)
• Excellent DC performance
• Good surge withstand profile

240Vac/150Vdc - 6 to 900A

Accessories
Trip-indicator fuses are available for use in parallel with the
main fuse. Indicator fuses can be attached to the associated
fuselink, or mounted separately in panel-mounted fuseclips.
In addition, a push-on adaptor and microswitch attachment
are available, to provide remote indication. Fuseblocks are
also available for most applications.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc. Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, Std. 248-13
Watts loss provided at rated current.
Electrical Characteristics

Ordering Information
I2t (A2 SEC)

Size

LCT

LET

LMT

LMMT

Rated Current
RMS-Amps
6
10
12
16
20
25
32
35
50
63
80
100
125
160
180
160
200
250
315
355
400
450
400
500
630
710
800
900

Pre-arc

Clearing
at 120V

Clearing
at 240V

2
3.8
7
20
25
18
32
50
100
180
300
600
600
1100
1600
1100
1500
3200
6000
8000
14000
18000
6000
14000
24000
32000
52000
75000

6
12
22
50
80
120
200
320
500
1100
1900
3800
3800
7000
12000
7000
10000
20000
35000
50000
70000
100000
35000
80000
150000
200000
300000
400000

9
22
32
100
160
250
450
600
1400
2200
3800
7500
7500
16000
29000
16000
20000
40000
75000
100000
160000
220000
80000
170000
300000
460000
600000
800000

Watts
Loss

Part Number

Carton Qty.

1.0
2.5
2.5
2.5
4.0
4.0
5.0
5.0
7.0
9.0
10.0
10.0
16.0
20.0
21.0
17.0
28.0
28.0
35.0
35.0
40.0
42.0
60.0
64.0
75.0
77.0
82.0
97.0

6LCT
10LCT
12LCT
16LCT
20LCT
25LET
32LET
35LET
50LET
63LET
80LET
100LET
125LET
160LET
180LETa
160LMT
200LMT
250LMT
315LMT
355LMT
400LMT
450LMT
400LMMT
500LMMT
630LMMT
710LMMT
800LMMT
900LMMT

20
20
20
20
20
10
10
10
10
10
10
10
10
10
10
1
1
1
1
1
1
1
1
1
1
1
1
1

Carton Weight (Kg)

Note: 7LET, 10LET, 12LET and 16LET are available for replacement purposes on existing equipment (not UL recognized).

Data Sheet: 720004

148

For complete specification data, call Bussmann Information Fax ~636.527.1450

0.110
0.110
0.110
0.110
0.110
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.310
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.370
0.370
0.370
0.370
0.370
0.370

Bussmann®

High Speed Fuses

British Standard BS88: Part 4
690Vac/500Vdc 6-700A
Interrupting Rating: 200kA RMS Symmetrical.
UL Recognized, Std. 248-13, Watts loss provided at rated current.
MT, MMT and additional ratings of ET and EET are available for replacement purposes on existing
equipment and are BS 88: Part 4 approved.
Electrical Characteristics

Ordering Information
I2t (A2 SEC)

Size

CT

ET

FE

EET

FEE

FM

FMM

MT†

MMT†

Rated Current
RMS-Amps
6
10
12
16
20
25
32
35
40
45
56
63
80
35
40
45
50
63
71
80
90
100
90
110
140
160
100
120
140
160
180
200
180
200
225
250
280
315
350
400
450
500
550
630
700
160
180
200
250
280
315
355
180
200
225
280
315
355
400
450
500
560
630
710

Pre-arc
1.8
7
10
16
32
25
32
52
103
103
135
171
360
33
52
76
103
135
210
250
360
470
490
600
1050
1500
400
540
850
1000
1400
1900
1400
2600
3700
5200
7000
10000
15000
10000
15000
20000
30000
45000
60000
2400
3800
6000
11500
16500
19000
22000
1650
2200
3700
6600
8600
13500
21000
30000
42000
60000
68500
78000

Clearing
at 415V
8.5
30
40
66
150
150
190
310
600
680
950
1200
2500
130
180
270
380
480
600
900
1300
1800
3000
4000
7000
10000
1600
1900
2500
3700
5300
7100
7500
10500
14500
20500
30500
40000
60000
40000
60000
82000
120000
180000
245000
15000
25000
40000
80000
100000
125000
160000
12000
16000
26000
47000
62000
97000
150000
220000
300000
430000
500000
600000

Clearing
at 660V
12
48
65
110
220
250
350
500
900
1100
1500
2000
4000
200
300
450
600
750
950
1500
2100
2800
4500
6500
12000
17000
2400
3100
3800
5700
8400
11400
13500
18500
26500
37500
55000
77000
105000
72500
105000
150000
215000
310000
420000
25000
38000
58000
110000
150000
180000
200000
18000
23000
40000
70000
91000
140000
220000
320000
450000
640000
720000
850000

Watts
Loss
2
3
3
7
7
7
11
11
9
11
14
16
18
9
9
11
11
12
17
20
20
23
19
27
35
39
24
32
36
46
46
52
40
40
44
48
48
55
55
85
90
100
100
100
120
26
26
27
32
35
42
51
42
42
42
47
51
54
60
57
64
64
86
105

Part Number

Carton Qty.

6CT
10CT
12CT
16CT
20CT
25ET
32ET
35ET
40ET
45ET
56ET
63ET
80ET
35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
90EET
110EET
140EET
160EET
100FEE
120FEE
140FEE
160FEE
180FEE
200FEE
180FM
200FM
225FM
250FM
280FM
315FM
350FM
400FMM
450FMM
500FMM
550FMM
630FMM
700FMM
160MT
180MT
200MT
250MT
280MT
315MT
355MT
180MMT
200MMT
225MMT
280MMT
315MMT
355MMT
400MMT
450MMT
500MMT
560MMT
630MMT
710MMT

20
20
20
20
20
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Carton Weight (Kg)
0.160
0.160
0.160
0.160
0.160
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.420
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.450
0.240
0.240
0.240
0.240
0.240
0.240
0.240
0.450
0.450
0.450
0.450
0.450
0.450
0.260
0.260
0.260
0.260
0.260
0.260
0.260
.0470
.0470
.0470
.0470
.0470
.0470
.0470
.0470
.0470
.0470
.0470
.0470

Note: 8ET, 12ET, 15ET, 20ET, 65EET and 75EET are available for replacement purposes on existing equipment (not UL recognized).
† 350Vdc (IEC) rating. No UL Recognition.

Data Sheet: 720024
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

149

Bussmann®

High Speed Fuses

Indicator System and Fuse Bases (Blocks)
Microswitch and Adaptor Type MAI
Current Rating:
ac 50/60Hz resistive load @ 250 VRMS
ac 50/60Hz resistive load @ 127 VRMS

Trip Indicator

4A
6A

dc, resistive load @ 110 Vdc
dc, resistive load @ 30 Vdc

0.7
2

Maximum Working Voltage:
Contact-to-contact (RMS)
Contact-to-contact (RMS)
2.8

2.4

1000V
1500V
3.6

5.2

5.2

44 36

Trip-indicator fuselinks are available for use in parallel
with the main fuselinks. They can either be attached to
the associated fuselink or mounted separately in panel
mounted fuse clips, Part No. CL1. A push-on adaptor
and microswitch attachment is available for use with the
trip indicator to give the facility of remote indication,
reference MAI or MBI.

9.5
NO

NC NC

21
NO

3.6

44 36

MAI

MAI

21

or

or

MBI

MBI

Universal and Stud Fuseblocks

Fuse ratings of 20A and below cannot usually accommodate a trip fuselink in parallel.
Where trip indicator fuselinks are to be attached to the
main fuselink, an accessory pack comprising a pair of
mounting clips and an appropriate trip indicator fuselink
will be required.
The ordering code references for these packs are listed
below:
Fuse Type
ET
EET
FE
FEE
LET

Order Ref.
EC-600
EC-600
EC-600
EC-600
EC-250

Fuse Type
FM
FMM
LMT
LMMT

A

0.8

Order Ref.
MC-600
MC-600
MC-250
MC-250

Dimensions in mm.
1mm = 0.0394∑
1∑ = 25.4mm

Stud Fuseblocks
Part No.
C5268-1
C5268-2
C5268-3
C5268-4
C5268-5

Trip-indicator Fuselink Data
Dim. ‘A’
Voltage
Type
Max.
Rating
TI250
37.6
250
TI500
47.5
500
TI600
55.7
600
TI700
61.8
700

Universal Fuseblocks
Modular
Max.
Base
Voltage
1BS101
600V
1BS102
600V
1BS103
600V
1BS104
600V

6

21
6.35

6

Type
TI1100
TI1500
TI2000
TI2500

Dim. ‘A’
Max.
98.4
120.8
147.5
198.3

Voltage
Rating
1100
1500
2000
2500

Stud Height
1.00∑
1.75∑
0.75∑
1.00∑
1.75∑

Stud Dia. & Threads
fiΩ¡§-18
fiΩ¡§-18
fiΩ¡§-18
⁄Ω¢-20
⁄Ω¢-20

Max. Fuse
Current Rating
100A
400A
400A
600A

Data Sheet: 720037

150

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data
Sheet
1206
1207
1208
1209

Bussmann®

High Speed Fuses

Ferrule Style

Voltage Rating
150Vac/dc

5 to 60A

250Vac/dc*

1 to 50A

500Vac/dc*

0.25 to 30A

600 ac/400 dc

6 to 32A

700Vac/dc**

1 to 50A

700Vac

1 to 100A

750Vac/dc

5 to 60A

1000 ac/800 dc

20 to 30A

1250 ac/1000 dc

20 to 30A

1500 ac/1000 dc

8 to 15A

2000/1000Vac/dc
*dc is for 5-30A
**500Vdc for 63-100A

2 to 6A

Select Fuses designed and tested to:
• IEC 60269: Part 4
• UL Recognized, Std. 248-13
Bussmann offers a full line of Ferrule Style (cylindrical and
clip-mounted) fuses, designed and tested to meet standards
and requirements in various locations around the world. Their
unique design and construction provide:
• Superior cycling capability
• Low energy let-thru (I2t)
Ferrule fuses provide an excellent solution for small UPS,
small AC drives and other low power applications where
space is at a premium.
Accessories
Ferrule fuses may be mounted in fuse clips, fuseholders,
fuseblocks or fused switches. A variety of products are available to suit most end-use requirements.

All Bussmann Ferrule fuses—except 690V—have been tested
at their rated voltage. The 690V Ferrule fuse has been tested
to the IEC 60269 standard, which requires clearing at the
rated voltage +5%.

FWA 150Vac/150Vdc
Interrupting Rating: 100kA RMS Symmetrical.
Agency Information: UL Recognized, 150V, Std. 248-13
Watts loss provided at rated current.
Electrical Characteristics

Ordering Information
I2t (A2 SEC)
Pre-arc

Clearing
at 150V

5

1.6

8

1

10

3.6

16

10 x 38 mm

15

14

(⁄‹Ω£™∑)

20

Size

21 x 51 mm
(⁄‹Ω¡§∑)

Rated Current
RMS-Amps

Watts
Loss

Part Number

Carton Qty.

FWA-5A10F

10

Carton Weight (Kg)
0.100

2.7

FWA-10A10F

10

0.100

55

3.3

FWA-15A10F

10

0.100

33

130

3.8

FWA-20A10F

10

0.100

25

58

220

4.9

FWA-25A10F

10

0.100

30

100

400

4.9

FWA-30A10F

10

0.100

35

75

800

4.5

FWA-35A21F

10

0.600

40

100

1000

5.1

FWA-40A21F

10

0.600

45

130

1300

6

FWA-45A21F

10

0.600

50

170

1600

7.3

FWA-50A21F

10

0.600

60

250

2400

8.0

FWA-60A21F

10

0.600

Data Sheet: 720003
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

151

Bussmann®

High Speed Fuses

Ferrule Style
FWX 250Vac/250Vdc (250Vdc on 5 through 30)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, 250V, Std. 248-13 & CSA Component Acceptance
Watts loss provided at rated current.
Electrical Characteristics

Ordering Information
I2t (A2 SEC)

Size

14 ≈ 51mm

Rated Current
RMS-Amps

Pre-arc

Clearing
at 250V

Watts
Loss

Part Number

Carton Qty.

1

—

—

—

FWX-1A14F

10

0.225

2

—

—

—

FWX-2A14F

10

0.225

3

—

—

—

FWX-3A14F

10

0.225

4

—

—

—

FWX-4A14F

10

0.225

5

1.6

13

1.3

FWX-5A14F

10

0.225

10

3.6

24

3.4

FWX-10A14F

10

0.225

15

14

83

3.8

FWX-15A14F

10

0.225

20

33

200

4.6

FWX-20A14F

10

0.225

25

58

300

5.3

FWX-25A14F

10

0.225

30

100

500

5.9

FWX-30A14F

10

0.225

50

200

1800

5.7

FWX-50A14F

10

0.225

Fuse Block: 1976 - (pole) Data Sheet: 1210

Carton Weight (Kg)

Data Sheet: 720006

FWH 500Vac/500Vdc
Interrupting Rating: 6 mm ≈ 32 mm (Interrupting rating
varies—See Data Sheet for details)
14 mm x 51 mm (200kA RMS Symmetrical).
Electrical Characteristics

Agency Information: UL Recognized, 500V, Std. 248-13 &
CSA Component Acceptance
Watts loss provided at rated current.
CE logo denotes compliance with European Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or contact Bussmann Application Engineering at
636-527-1270 for more information.

Ordering Information
I2t (A2 SEC)

Size

6 x 32 mm
(⁄Ω¢∑ ≈ 1⁄Ω¢∑)

14 ≈ 51mm
(·Ω¡§∑)

Rated Current
RMS-Amps
0.25
0.5
1
2
3.15
5
6.3
7
10
12.5
15
16
20
25
30
1
2
3
4
5
6
10
12
15
20
25
30

Pre-arc

Clearing
at 500V

0.01
0.05
0.4
1.3
3.1
15
36
50
9.9
20
44
48
75
126
145
—
—
—
—
1.6
1.6
3.6
—
10
26
49
58

0.05
0.25
2
3.5
7.7
40
90
125
139
60
146
177
259
345
430
—
—
—
—
6.4
6.4
13
—
40
96
191
232

Watts
Loss

Part Number

2.7
1.2
1.7
3.2
2.9
2.1
2.3
2.5
2.86
3.53
3.08
4.48
4.26
—
—
—
—
2.3
—
1.5
1.5
4
—
5.5
6
7
9

FWH-.250A6F*
FWH-.500A6F*
FWH-001A6F*
FWH-002A6F*
FWH-3.15A6F*
FWH-005A6F*
FWH-6.30A6F*
FWH-007A6F*
FWH-010A6F
FWH-12.5A6F
FWH-015A6F
FWH-016A6F
FWH-020A6F
FWH-025A6F
FWH-030A6F
FWH-1A14F
FWH-2A14F
FWH-3A14F
FWH-4A14F
FWH-5A14F**
FWH-6A14F**
FWH-10A14F**
FWH-12A14F**
FWH-15A14F**
FWH-20A14F**
FWH-25A14F**
FWH-30A14F**

Data Sheet: 14mm ≈ 51mm, 720008 & 6mm ≈ 32mm, 720038

152

Carton Qty.

Carton Weight (Kg)

10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

*CSA Component Acceptance
**UL Recognized & CSA Component Acceptance at 500Vdc

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.250
0.250
0.250
0.250
0.250
0.250
0.250
0.250
0.250
0.250
0.250
0.250

Bussmann®

High Speed Fuses

Ferrule Style
FWC 600Vac
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, 600V, Std. 248-13
Watts loss provided at rated current.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Ordering Information
I2t (A2 SEC)
Watts
Loss

Part Number

Carton Qty.

30

1.5

FWC-6A10F

10

0.100

6

50

2.0

FWC-8A10F

10

0.100

10

9

70

2.5

FWC-10A10F

10

0.100

10 x 38 mm

12

15

120

3.0

FWC-12A10F

10

0.100

(⁄‹Ω£™∑ )

16

25

150

3.5

FWC-16A10F

10

0.100

20

34

260

4.8

FWC-20A10F

10

0.100

25

60

390

6.0

FWC-25A10F

10

0.100

32

95

600

7.5

FWC-32A10F

10

0.100

Size

Rated Current
RMS-Amps

Pre-arc

Clearing
at 600V

6

4

8

Carton Weight (Kg)

 400Vdc UL Recognition: 32A: Interrupting Rating = 50kA
 700VdcUL Recognition: 6-25A: Interrupting Rating = 50kA

Fuse Block: BM Series Data Sheet: 1104
Data Sheet: 720011

FWP 690V/700V (IEC/UL)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, 700V, Std. 248-13 &
CSA Component Acceptance.
Watts loss provided at rated current.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Ordering Information
I2t (A2 SEC)
Watts
Loss

Part Number

Carton Qty.

Carton Weight (Kg)

—

—

FWP-1A14F

5

0.113

—

—

—

FWP-2A14F

5

0.113

2.5

—

—

—

FWP-2.5A14F

5

0.113

3

—

—

—

FWP-3A14F

5

0.113

4

—

—

—

FWP-4A14F

5

0.113

5

1.6

4

1.5

FWP-5A14F

10

0.225

6.3

—

—

—

FWP-6.3A14F

10

0.225

10

3.6

10

4

FWP-10A14F

10

0.225

14 x 51mm

15

10

22

5.5

FWP-15A14F

10

0.225

(·Ω¡§∑ )

20

26

60

6

FWP-20A14F

10

0.225

25

44

130

7

FWP-25A14F

10

0.225

30

58

150

9

FWP-30A14F

10

0.225

32

95

800

7.6

FWP-32A14F

5

0.113

40

110

980

8

FWP-40A14F

5

0.113

50

220

1800

9

FWP-50A14F

5

0.113

Size

Rated Current
RMS-Amps

Pre-arc

Clearing
at 660V

1

—

2

Fuse Block: 1976 - (pole) Data Sheet: 1210

▫ CSA Component Acceptance 5-30A
Data Sheet: 720025

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

153

Bussmann®

High Speed Fuses

Ferrule Style
FWP 690V/700V (IEC/UL)
Interrupting Rating: 200kA RMS Symmetrical.
Agency Information: UL Recognized, 700V, Std. 248-13 &
CSA Component Acceptance
Watts loss provided at rated current.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Ordering Information
I2t (A2 SEC)

Rated Current
RMS-Amps

Watts
Loss

Part Number

370

4.6

FWP-20A22F

10

0.450

60

560

5.6

FWP-25A22F

10

0.450

32

95

850

7.0

FWP-32A22F

10

0.450

22 ≈ 58 mm

40

185

1350

8.5

FWP-40A22F

10

0.450

(‡Ω•∑ )

50

155

1120

9.5

FWP-50A22F

10

0.450

63

310

2700

11

FWP-63A22F

10

0.450

80

620

5100

13.5

FWP-80A22F

10

0.450

100

1250

10000

16

FWP-100A22F

10

0.450

Size

Pre-arc

Clearing
at 660V

20

34

25

Carton Qty.

Carton Weight (Kg)

 500Vdc UL Recognition: Interrupting Rating = 50kA

Fuse Block: J70100 - (pole) CR Data Sheet: 1211

Data Sheet: 720026

FWK 750V

Size

5-60A

Electrical Characteristics
Rated
I2t (A2S)
Current
Clearing
RMS-Amps
Pre-arc
at 750 VDC

20 ≈ 127mm
(⁄‹Ω¡§∑)

25 ≈ 146mm
(1∑)

5
8
10
15
20
25
30
35
40
50
60

8.5
50
95
100
125
400
800
1300
1600
3100
5900

16
100
200
240
315
1100
2600
4300
5300
12000
24000

 Interrupting rating 45kA RMS symmetrical.
 750Vdc rating for 5 through 60A (Time constant = 10-15 mS).

Ordering Information
Watts
Loss

Part
Number

—
—
—
—
—
—
—
—
—
—
—

FWK-5A20F
FWK-8A20F
FWK-10A20F
FWK-15A20F
FWK-20A20F
FWK-25A20F
FWK-30A20F
FWK-35A25F
FWK-40A25F
FWK-50A25F
FWK-60A25F

Dimensions

Carton
Qty.

Carton
Weight
(kg)

Figure
Number

10

0.95

Fig. 1

10

1.65

Fig. 2

1 kg = 2.2 lbs.

1 lb = 0.45 kg

Data Sheet: 720039

154

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

High Speed Fuses

Ferrule Style
FWJ 1000Vac
Interrupting Rating: 25kA RMS Symmetrical.
Agency Information: UL Recognized, 1000Vac/800Vdc,
Std. 248-13
Watts loss provided at rated current.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Electrical Characteristics

Ordering Information
I2t (A2 SEC)

Rated Current
RMS-Amps

Size
14 ≈ 67 mm
(·Ω¡§∑)

Pre-arc

Clearing
at 1000V

Watts
Loss

20

25

Part Number

220

9

FWJ-20A14F

10

25

0.300

33

350

11

FWJ-25A14F

10

30

0.300

52

450

14

FWJ-30A14F

10

0.300

Carton Qty.

Carton Weight (Kg)

 800Vdc UL Recognition

Data Sheet: 720028

FWL/FWS 1250V/1500V/2000V

Size

Electrical Characteristics
Rated
I2t (A2S)
Current
Clearing
RMS-Amps
Pre-arc
at 1000 Vdc

¥2
0.8
¥6
27
†8
64
†10
118
20 ≈ 127mm
†12
170
(⁄‹Ω¡§∑)
†15
209
‡20
675
‡25
1200
‡30
1850
 Interrupting rating 45kA RMS Symmetrical.
 Rated voltage (IEC) ¥2000V †1500V ‡1250V
 1000Vdc/30kA rating.

2.4
81
192
277
380
500
1550
2760
4300

Ordering Information
Watts
Loss

4.4
6.7
7.6
3.0
3.4
5.0
5.9
6.5
7.5

Part
Number

FWS-2A20F
FWS-6A20F
FWS-8A20F
FWS-10A20F
FWS-12A20F
FWS-15A20F
FWL-20A20F
FWL-25A20F
FWL-30A20F

Carton
Qty.

Carton
Weight
(kg)

10

1.00

Dimensions

Curves

Figure
Number

See Page

Fig. 1

page 108

1 kg = 2.2 lbs.

1 lb = 0.45 kg

Data Sheet: 720040
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

155

Page 156
BLANK
(Do NOT Print)

Bussmann®

Medium Voltage Fuses and Fuse Links

BBU Boric Acid Fuse-Features
Construction
Principle parts of the replaceable BBU
fuse unit are shown in the cross section view. Main operating parts are
the silver element, arcing rod, boric
acid cylinder, and spring. A glass
epoxy tube encloses the assembly.

ption is achieved by the action of an
arcing rod and a charged spring, elongating the arc through a boric acid
chamber upon release by the fuse
element.

When the fuse operates, the upward
motion of the spring forces the top of
the arcing rod to penetrate the upper
seal, striking the latch mechanism.
On indoor applications, this action
caused the blown fuse indicator to
actuate.
When replacing the blown fuse, the
end fittings should be removed from
the operated fuse unit, and if undamaged, clamped onto the new fuse
unit.

The use of a pure silver element and
Nichrome wire strain element makes
the BBU less susceptible to outages
caused by vibration, corona corrosion,
and aging of the fuse elements.

Application
The BBU Boric acid Fuse provides
effective protection for circuits and
equipment which operate on voltage
systems up to 34,500V. They can be
used on industrial distribution systems and all fuses are designed for
use on the following:
Power Transformers
Feeder Circuits
Distribution Transformers
Element
Melts

Vapor
Rod withdraws,
quenches
elongating arc
and vaporizing arc at first
current zero
Boric Acid

At high temperatures, boric acid
decomposes producing a blast of
water vapor and inert boric anhydride.
Electrical interruption is caused by the
steam extinguishing the arc, as the
arc is being elongated through the
cylinder.

BBU Fuse Construction
The components are housed in a
fiberglass reinforced resin tube with
plated copper contacts. Positive connection is maintained between the
arcing rod and contact with a sliding
tulip contact.

Operation
BBU Expulsion Fuses utilize the
proven performance of boric acid to
create the de-ionizing action needed
to interrupt the current. Fault interru-

Higher particle turbulence of the boric
acid causes the rate of de-ionization
in the cylinder to exceed the ionization of the electrical arc. Both high
and low current faults are interrupted
in the same manner with no foreign
material other than the boric acid
required. This enables the fuse to
interrupt short circuits within one-half
cycle and prevents the arc from
restriking after a current zero.
After interruption, the gases are
expelled from the bottom of the fuse.
The arching rod is prevented from
falling back into its original position by
a friction stop at the top of the fuse
unit.

Metal-enclosed Switchgear
Pad Mount Switches
BBU Fuse units can be used in
indoor applications, and can be used
to directly replace competitive equivalent units.

BBU End Fittings
End Fittings are required to complete
the electrical connection between the
fuse unit and the live parts and
mounting.
End fittings are positioned on the top
and bottom of the fuse unit. They
can be used over again if they remain
undamaged.
The indoor fittings accept a Muffler
attachment to limit noise and contamination to indoor equipment. The
blown fuse indicator located on the
top end fitting, provides visual indication of a faulted fuse unit.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

157

Bussmann®

Medium Voltage Fuses and Fuse Links
BBU Boric Acid Fuses for Use Indoors

158

Catalog Number

Ampere Rating
5E to 200E

BBU-EFID
BBU-EFID

15SE to 200SE

BBU-EFID

3K to 200K

BBU-EFID

5E to 200E

BBU-EFID

BBU27-50E 12.5
BBU27-65E
BBU27-80E
BBU27-100E
BBU27-125E
BBU27-150E
BBU27-175E
BBU27-200E
BBU27-15SE
BBU27-20SE
BBU27-25SE
BBU27-30SE
BBU27-40SE
BBU27-50SE
BBU27-65SE
BBU27-80SE 12.5
BBU27-100SE
BBU27-125SE
BBU27-150SE
BBU27-175SE
BBU27-200SE
BBU38-3K
BBU38-6K
BBU38-8K
BBU38-10K
BBU38-12K
BBU38-15K
BBU38-20K
10
BBU38-30K
BBU38-40K
BBU38-50K
BBU38-65K
BBU38-80K
BBU38-100K
BBU38-140K
BBU38-200K
BBU38-5E
BBU38-7E
BBU38-10E
BBU38-13E
BBU38-15E
BBU38-20E
BBU38-25E
BBU38-30E
BBU38-40E
BBU38-50E
10
BBU38-65E
BBU38-80E
BBU38-100E
BBU38-125E
BBU38-150E
BBU38-175E
BBU38-200E
BBU38-15SE
BBU38-20SE
BBU38-25SE
BBU38-30SE
BBU38-40SE
BBU38-50SE
BBU38-65SE
BBU38-80SE
10
BBU38-100SE
BBU38-125SE
BBU38-150SE
BBU38-175SE
BBU38-200SE

15SE to 200SE

27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38
38

End Fittings

Voltage (kV)

E
E
E
E
E
E
E
E
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE

Max. Int. kA Sym

Fuse Type

50
65
80
100
125
150
175
200
15
20
25
30
40
50
65
80
100
125
150
175
200
3
6
8
10
12
15
20
30
40
50
65
80
100
140
200
5
7
10
13
15
20
25
30
40
50
65
80
100
125
150
175
200
15
20
25
30
40
50
65
80
100
125
150
175
200

Catalog
Number

Amps

Catalog Number

Ampere Rating
3K to 200K

BBU-EFID
BBU-EFID

5E to 200E

BBU-EFID

15SE to 200SE

BBU-EFID

3K to 200K

BBU-EFID

BBU17-3K
BBU17-6K
BBU17-8K
BBU17-10K
BBU17-12K
BBU17-15K
BBU17-20K
14
BBU17-25K
BBU17-30K
BBU17-40K
BBU17-50K
BBU17-65K
BBU17-80K
BBU17-100K
BBU17-140K
BBU17-200K
BBU17-5E
BBU17-7E
BBU17-10E
BBU17-13E
BBU17-15E
BBU17-20E
BBU17-25E
BBU17-30E
14
BBU17-40E
BBU17-50E
BBU17-65E
BBU17-80E
BBU17-100E
BBU17-125E
BBU17-150E
BBU17-175E
BBU17-200E
BBU17-15SE
BBU17-20SE
BBU17-25SE
BBU17-30SE
BBU17-40SE
BBU17-50SE
BBU17-65SE
14
BBU17-80SE
BBU17-100SE
BBU17-125SE
BBU17-150SE
BBU17-175SE
BBU17-200SE
BBU27-3K
BBU27-6K
BBU27-8K
BBU27-10K
BBU27-12K
BBU27-15K
BBU27-20K
BBU27-25K
BBU27-30K 12.5
BBU27-40K
BBU27-50K
BBU27-65K
BBU27-80K
BBU27-100K
BBU27-140K
BBU27-200K
BBU27-5E
BBU27-7E
BBU27-10E
BBU27-13E
BBU27-15E
BBU27-20E
BBU27-25E
BBU27-30E
BBU27-40E

Indoor

5E to 200E

17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27
27

End Fittings

Voltage (kV)

k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
SE
k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
k
E
E
E
E
E
E
E
E
E

Max. Int. kA Sym

Fuse Type

3
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
5
7
10
13
15
20
25
30
40
50
65
80
100
125
150
175
200
15
20
25
30
40
50
65
80
100
125
150
175
200
3
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
5
7
10
13
15
20
25
30
40

Catalog
Number

Amps

Indoor

*Note: Muffler can be ordered separately. Order Catalog number
BBU-MFLR.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Medium Voltage Fuses and Fuse Links

Bussmann®

E-Rated Medium Voltage Fuses: CL-14 & Bolt-In

Electrical Characteristics
Bussmann
Number

Ampere
Rating

Voltage

IR
Max Sym.

# of
Barrels

Figure #

Style

ECL055-10E
ECL055-15E
ECL055-20E
ECL055-25E
ECL055-30E
ECL055-40E
ECL055-50E
ECL055-65E
ECL055-80E
ECL055-100E
ECL055-125E
ECL055-150E
ECL055-200E
ECL055-250E
ECL055-300E
ECL055-400E
ECL055-450E
ECL055-500E
ECL055-600E
EBI055-750E
EBI055-900E

10E
15E
20E
25E
30E
40E
50E
65E
80E
100E
125E
150E
200E
250E
300E
400E
450E
500E
600E
750E
900E

5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV
5.5kV

63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA
63kA

1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
3
3

1
1
1
1
1
1
1
1
1
1
1
1
2
2
3
3
3
3
3
4
4

Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Clip-Lock
Bolt-In
Bolt-In

Part Number Construction
Example

Catalog Symbol
ECL

Voltage Rating
055

Ampere Rating
500E

055 = 5.5 kV

Catalog Number Cross Reference
Bussmann

ECL055-10E
ECL055-15E
ECL055-20E
ECL055-25E
ECL055-30E
ECL055-40E
ECL055-50E
ECL055-65E
ECL055-80E
ECL055-100E
ECL055-125E
ECL055-150E
ECL055-200E
ECL055-250E
ECL055-300E
ECL055-400E
ECL055-450E
ECL055-500E
ECL055-600E
EBI055-750E
EBI055-900E

Ferraz-Shawmut
New Catalog #

A055C1DORO-10E
A055C1DORO-15E
A055C1DORO-20E
A055C1DORO-25E
A055C1DORO-30E
A055C1DORO-40E
A055C1DORO-50E
A055C1DORO-65E
A055C1DORO-80E
A055C1DORO-100E
A055C1DORO-125E
A055C1DORO-150E
A055C1DORO-200E
A055C1DORO-250E
A055C1DORO-300E
A055C1DORO-400E
A055C2DORO-450E
A055C2DORO-500E
A055C2DORO-600E
AO55B3DORO-750E
AO55B3DORO-900E

Ferraz-Shawmut
Old Catalog #

225-007-937
225-007-938
225-007-939
225-007-940
225-007-941
225-007-942
225-007-943
225-007-944
225-007-945
225-007-946
225-007-947
225-007-948
225-007-949
225-007-950
225-007-951
225-007-952
225-007-953
225-007-954
225-007-955
A055X750E-4
A055X900E-4

CATALOG SYMBOL: ECL055 & EBI055
E-RATED MEDIUM VOLTAGE FUSES:
Meets E requirements per ANSI C37.46
Meets General Purpose requirements per ANSI C37.40
FOR TRANSFORMER AND FEEDER PROTECTION
VOLTAGE RATING: 5.5 KV
INTERRUPTING RATING: 63KA Maximum Sym.
CURRENT LIMITING
CONSTRUCTION:
• Silver element in a double concentric helical configuration
• Silica filler
• Silver plated copper terminals and endcaps
• Filament wound, glass epoxy fuse tube
FEATURES:
• General Purpose Fuses. Bussmann’s medium voltage
fuses provide general purpose protection and are capable of
interrupting fault currents up to 63,000A RMS sym.
• Clip-lock and bolt-in style available in double and triple
barrel fuse designs.
• Indoor and Outdoor Usage. The filament wound, glass
epoxy fuse tube provides UV and moisture protection for the
fuse. This makes Bussmann’s medium voltage fuses suitable
for both indoor and outdoor applications.
• Open Fuse Indication. Indicator travel distance is 16mm.
• Operating Frequency: 50/60 Hz
Current-limiting medium voltage fuses are
classified into three categories:
Full Range - defined by ANSI as “a fuse capable of interrupting all currents from the maximum rated interrupting
current down to the minimum continuous current that causes melting of the fusible element(s), when the fuse is applied
at the maximum ambient temperature specified by the manufacturer.” It is able to interrupt any normal 60 cycle current
that will melt its element.
General Purpose - defined by ANSI C37.40 as “a fuse
capable of interrupting all currents from the maximum rated
interrupting current down to the current that causes melting
of the fusible element in one hour.” Not all currents fall within this range. It is possible to receive an overcurrent lower
than the value given by the one hour criterion.
Back-up - defined by ANSI C37.40 as “a fuse capable of
interrupting all currents from the maximum rated interrupting
current down to the rated minimum interrupting current.”
The minimum rated interrupting current is the lowest current
that the fuse will be able to clear properly. This creates a
need to place a low current interrupting device in series with
the back-up rated fuse.

Data Sheet: 9002
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

159

Medium Voltage Fuses and Fuse Links

Bussmann®

E-Rated Medium Voltage Fuses: CL-14

Electrical Characteristics
Bussmann
Number

Ampere
Rating

Voltage

IR
Max Sym.

# of
Barrels

Figure #

Style

ECL155-10E

10E

15.5kV

63KA

1

1

Clip-Lock

ECL155-15E

15E

15.5kV

63KA

1

1

Clip-Lock

ECL155-20E

20E

15.5kV

63KA

1

1

Clip-Lock

ECL155-25E

25E

15.5kV

63KA

1

1

Clip-Lock

ECL155-30E

30E

15.5kV

63KA

1

1

Clip-Lock

ECL155-40E

40E

15.5kV

63KA

1

1

Clip-Lock

ECL155-50E

50E

15.5kV

63KA

1

1

Clip-Lock

ECL155-65E

65E

15.5kV

63KA

1

2

Clip-Lock

ECL155-80E

80E

15.5kV

63KA

1

2

Clip-Lock

ECL155-100E

100E

15.5kV

63KA

1

2

Clip-Lock

ECL155-125E

125E

15.5kV

63KA

1

2

Clip-Lock

ECL155-150E

150E

15.5kV

63KA

2

3

Clip-Lock

ECL155-200E

200E

15.5kV

63KA

2

3

Clip-Lock

ECL155-250E

250E

15.5kV

50kA

2

3

Clip-Lock

ECL155-300E

300E

15.5kV

50kA

2

3

Clip-Lock

Part Number Construction
Catalog Symbol

Voltage Rating

Ampere Rating

ECL

155

300E

Example

155 = 15.5 kV

Catalog Number Cross Reference
Ferraz-Shawmut
New Catalog #

Ferraz-Shawmut
Old Catalog #

ECL155-10E

A155C1DORO-10E

225-007-967

ECL155-15E

A155C1DORO-15E

225-007-968

ECL155-20E

A155C1DORO-20E

225-007-969

ECL155-25E

A155C1DORO-25E

225-007-970

ECL155-30E

A155C1DORO-30E

225-007-971

ECL155-40E

A155C1DORO-40E

225-007-972

ECL155-50E

A155C1DORO-50E

225-007-973

ECL155-65E

A155C1DORO-65E

225-007-974

ECL155-80E

A155C1DORO-80E

225-007-975

ECL155-100E

A155C1DORO-100E

225-007-976

ECL155-125E

A155C2DORO-125E

225-007-977

ECL155-150E

A155C3DORO-150E

225-007-978

ECL155-200E

A155C3DORO-200E

225-007-979

ECL155-250E

A155C3DORO-250E

225-007-980

ECL155-300E

A155C3DORO-300E

225-007-981

Bussmann

CATALOG SYMBOL: ECL155
E-RATED MEDIUM VOLTAGE FUSES:
Meets E requirements per ANSI C37.46
Meets General Purpose requirements per ANSI C37.40
FOR TRANSFORMER AND FEEDER PROTECTION
VOLTAGE RATING: 15.5 KV
INTERRUPTING RATING: See table.
CURRENT LIMITING
CONSTRUCTION:
• Silver element in a double concentric helical configuration
• Silica filler
• Silver plated copper terminals and endcaps
• Filament wound, glass epoxy fuse tube
FEATURES:
• General Purpose Fuses. Bussmann’s medium voltage
fuses provide general purpose protection and are capable
of interrupting fault currents up to 50,000A RMS sym.
• Clip-Lock Double Barrel Fuse Design.
• Indoor and Outdoor Usage. The filament wound, glass
epoxy fuse tube provides UV and moisture protection for
the fuse. This makes Bussmann’s medium voltage fuses
suitable for both indoor and outdoor applications.
• Open Fuse Indication. Indicator travel distance is 16mm.
• Operating Frequency: 50/60 Hz
Current-limiting medium voltage fuses are
classified into three categories:
Full Range - defined by ANSI as “a fuse capable of interrupting all currents from the maximum rated interrupting
current down to the minimum continuous current that
causes melting of the fusible element(s), when the fuse is
applied at the maximum ambient temperature specified by
the manufacturer.” It is able to interrupt any normal 60
cycle current that will melt its element.
General Purpose - defined by ANSI C37.40 as “a fuse
capable of interrupting all currents from the maximum rated
interrupting current down to the current that causes melting
of the fusible element in one hour.” Not all currents fall
within this range. It is possible to receive an overcurrent
lower than the value given by the one hour criterion.
Back-up - defined by ANSI C37.40 as “a fuse capable of
interrupting all currents from the maximum rated interrupting
current down to the rated minimum interrupting current.”
The minimum rated interrupting current is the lowest current
that the fuse will be able to clear properly. This creates a
need to place a low current interrupting device in series with
the back-up rated fuse.

BIF document: #9004

160

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

R-Rated Fuses for Motor Circuit Protection
JCK, JCK-A, JCK-B, JCH, JCL, JCL-A,
JCL-B, JCG, JCR, & JCR-B
R-Rated
Medium Voltage
Current Limiting
2400V AC — JCK, JCK-A, JCK-B, JCH
4800V AC — JCL, JCL-A, JCL-B, JCG
7200V AC — JCR, JCR-B
Max. Design Voltage: 2540Vac — JCK, JCK-A,
JCK-B, JCH
5080Vac — JCL, JCL-A
JCL-B, JCG
8300Vac — JCR, JCR-B
Agency Information:
UL Recognized : 2540Vac — JCK, JCK-A
5080Vac — JCL, JCL-A
UL Recognized (Guide #MSSS2, File #E96676)
Dimensional Data
INDICATOR
Showing Fuse is Open

0.38"
(9.5mm)

C

INDICATOR
Showing Fuse
is Open

A

B

Figure 1

Figure 2

Data Sheet: 6001
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

161

Bussmann®

Medium Voltage Fuses and Fuse Links

R-Rated Fuses for Motor Circuit Protection
Specifications
Buss
Catalog No.

Amperage

Maximum
Design Voltage

A

Dimensions (Inches)
B
C

Construction

Max. Int. Cap.
Amps (Asym.)

Amps (Sym.)

Min. Int. Cap.
Amps (Sym.)

2400V; R-Rated; Indoor/Enclosure (See Figure 1)
JCK-2R

70 2R

2540V

11.24

3.0

3.0

Single

80,000

50,000

165

JCK-3R

100 3R

2540V

11.24

3.0

3.0

Single

80,000

50,000

220

JCK-4R

130 4R

2540V

11.24

3.0

3.0

Single

80,000

50,000

320

JCK-5R

150 5R

2540V

11.24

3.0

3.0

Single

80,000

50,000

410

JCK-6R

170 6R

2540V

11.24

3.0

3.0

Single

80,000

50,000

480

JCK-9R

200 9R

2540V

11.24

3.0

3.0

Single

80,000

50,000

720

JCK-12R

230 12R

2540V

11.24

3.0

3.0

Single

80,000

50,000

970

JCK-18R

390 18R

2540V

11.24

3.0

3.0

Double

80,000

50,000

1,430

JCK-24R

450 24R

2540V

11.24

3.0

3.0

Double

80,000

50,000

1,880

2400V; R-Rated; Indoor/Enclosure; With Westinghouse Ampguard Hookeye (See Figure 1)
JCK-A-2R

70 2R

2540V

11.24

3.0

3.0

Single

80,000

50,000

165

JCK-A-3R

100 3R

2540V

11.24

3.0

3.0

Single

80,000

50,000

220

JCK-A-4R

130 4R

2540V

11.24

3.0

3.0

Single

80,000

50,000

320

JCK-A-5R

150 5R

27540V

11.24

3.0

3.0

Single

80,000

50,000

410

JCK-A-6R

170 6R

2540V

11.24

3.0

3.0

Single

80,000

50,000

480

JCK-A-9R

200 9R

2540V

11.24

3.0

3.0

Single

80,000

50,000

720

JCK-A-12R

230 12R

2540V

11.24

3.0

3.0

Single

80,000

50,000

970

JCK-A-18R

390 18R

2540V

11.24

3.0

3.0

Double

80,000

50,000

1,430

JCK-A-24R

450 24R

2540V

11.24

3.0

3.0

Double

80,000

50,000

1,880

2400V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2)
JCK-B-30

25

2540V

14.18

12.81

-

Single

80,000

50,000

90

JCK-B-2R

70 2R

2540V

14.18

12.81

-

Single

80,000

50,000

170

JCK-B-3R

100 3R

2540V

14.18

12.81

-

Single

80,000

50,000

245

JCK-B-4R

130 4R

2540V

14.18

12.81

-

Single

80,000

50,000

340

JCK-B-5R

150 5R

2540V

14.18

12.81

-

Single

80,000

50,000

430

JCK-B-6R

170 6R

2540V

14.18

12.81

-

Single

80,000

50,000

500

JCK-B-9R

200 9R

2540V

14.18

12.81

-

Single

80,000

50,000

1,000

JCK-B-12R

230 12R

2540V

14.18

12.81

-

Single

80,000

50,000

1,250

JCK-B-18R

390 18R

2540V

14.18

12.81

3.56

Double

80,000

50,000

1,700

JCK-B-24R

450 24R

2540V

14.18

12.81

3.56

Double

80,000

50,000

1,210

2400V; R-Rated; Indoor; Hermetically Sealed, Class 1, Group D, Div. 2, Hazardous Locations; For Use with Ampgard Motor Starters (See Figure 1)
JCH-30

25

2540V

10.81

3.0

3.0

Single

80,000

50,000

90

JCH-2R

70 2R

2540V

10.81

3.0

3.0

Single

80,000

50,000

170

JCH-3R

100 3R

2540V

10.81

3.0

3.0

Single

80,000

50,000

245

JCH-4R

130 4R

2540V

10.81

3.0

3.0

Single

80,000

50,000

340

JCH-5R

150 5R

2540V

10.81

3.0

3.0

Single

80,000

50,000

430

JCH-6R

170 6R

2540V

10.81

3.0

3.0

Single

80,000

50,000

500

JCH-9R

200 9R

2540V

10.81

3.0

3.0

Single

80,000

50,000

1,000

JCH-12R

230 12R

2540V

10.81

3.0

3.0

Single

80,000

50,000

1,250

JCH-18R

390 18R

2540V

10.81

3.0

3.0

Double

80,000

50,000

1,700

JCH-24R

450 24R

2540V

10.81

3.0

3.0

Double

80,000

50,000

2,100

4800V; R-Rated; Indoor/Enclosure (See Figure 1)
JCL-2R

70 2R

5080V

15.76

3.0

3.0

Single

80,000

50,000

165

JCL-3R

100 3R

5080V

15.76

3.0

3.0

Single

80,000

50,000

220

JCL-4R

130 4R

5080V

15.76

3.0

3.0

Single

80,000

50,000

320

JCL-5R

150 5R

5080V

15.76

3.0

3.0

Single

80,000

50,000

410

JCL-6R

170 6R

5080V

15.76

3.0

3.0

Single

80,000

50,000

480

JCL-9R

200 9R

5080V

15.76

3.0

3.0

Single

80,000

50,000

720

JCL-12R

230 12R

5080V

15.76

3.0

3.0

Single

80,000

50,000

970

JCL-18R

390 18R

5080V

15.76

3.0

3.0

Double

80,000

50,000

1,430

JCL-24R

450 24R

5080V

15.76

3.0

3.0

Double

80,000

50,000

1,880

162

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

R-Rated Fuses for Motor Circuit Protection
Specifications
Buss
Catalog No.

Amperage

Maximum
Design Voltage

A

Dimensions (Inches)
B
C

Construction

Max. Int. Cap.
Amps (Asym.)

Min. Int. Cap.
Amps (Sym.) Amps (Sym.)

4800V; R-Rated; Indoor/Enclosure; With Westinghouse Ampguard Hookeye (See Figure 1)
JCL-A-2R

70 2R

5080V

15.76

3.0

3.0

Single

80,000

50,000

165

JCL-A-3R

100 3R

5080V

15.76

3.0

3.0

Single

80,000

50,000

220

JCL-A-4R

130 4R

5080V

15.76

3.0

3.0

Single

80,000

50,000

320

JCL-A-5R

150 5R

5080V

15.76

3.0

3.0

Single

80,000

50,000

410

JCL-A-6R

170 6R

5080V

15.76

3.0

3.0

Single

80,000

50,000

480

JCL-A-9R

200 9R

5080V

15.76

3.0

3.0

Single

80,000

50,000

720

JCL-A-12R

230 12R

5080V

15.76

3.0

3.0

Single

80,000

50,000

970

JCL-A-18R

390 18R

5080V

15.76

3.0

3.0

Double

80,000

50,000

1,430

JCL-A-24R

450 24R

5080V

15.76

3.0

3.0

Double

80,000

50,000

1,880

4800V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2)
JCL-B-30

30

5080V

19.25

17.88

-

Single

80,000

50,000

95

JCL-B-2R

70 2R

5080V

19.25

17.88

-

Single

80,000

50,000

180

JCL-B-3R

100 3R

5080V

19.25

17.88

-

Single

80,000

50,000

270

JCL-B-4R

130 4R

5080V

19.25

17.88

-

Single

80,000

50,000

350

JCL-B-5R

150 5R

5080V

19.25

17.88

-

Single

80,000

50,000

450

JCL-B-6R

170 6R

5080V

19.25

17.88

-

Single

80,000

50,000

540

JCL-B-9R

200 9R

5080V

19.25

17.88

-

Single

80,000

50,000

700

JCL-B-12R

230 12R

5080V

19.25

17.88

-

Single

80,000

50,000

1,000

JCL-B-18R

390 18R

5080V

19.25

17.88

3.31

Double

80,000

50,000

1,450

JCL-B-24R

450 24R

5080V

19.25

17.88

3.31

Double

80,000

50,000

2,000

4800V; R-Rated; Indoor; Hermetically Sealed, Class 1, Group D, Div. 2, Hazardous Locations; For Use with Ampgard Motor Starters (See Figure 1)
JCG-30

30

5080V

15.91

3.0

3.0

Single

80,000

50,000

95

JCG-2R

70 2R

5080V

15.91

3.0

3.0

Single

80,000

50,000

180

JCG-3R

100 3R

5080V

15.91

3.0

3.0

Single

80,000

50,000

270

JCG-4R

130 4R

5080V

15.91

3.0

3.0

Single

80,000

50,000

350

JCG-5R

150 5R

5080V

15.91

3.0

3.0

Single

80,000

50,000

450

JCG-6R

170 6R

5080V

15.91

3.0

3.0

Single

80,000

50,000

540

JCG-9R

200 9R

5080V

15.91

3.0

3.0

Single

80,000

50,000

700

JCG-12R

230 12R

5080V

15.91

3.0

3.0

Single

80,000

50,000

1,000

JCG-A-18R

390 18R

5080V

15.91

3.0

3.0

Double

80,000

50,000

1,450

JCG-A-24R

450 24R

5080V

15.91

3.0

3.0

Double

80,000

50,000

2,000
160

7200V; R-Rated; Indoor/Enclosure; With Ampgard Hookeye (See Figure 1)
JCR-A-2R

70 2R

8300V

15.85

3.0

3.0

Single

80,000

50,000

JCR-A-3R

100 3R

8300V

15.85

3.0

3.0

Single

80,000

50,000

250

JCR-A-4R

130 4R

8300V

15.85

3.0

3.0

Single

80,000

50,000

325

JCR-A-5R

150 5R

8300V

15.85

3.0

3.0

Single

80,000

50,000

390

JCR-A-6R

170 6R

8300V

15.85

3.0

3.0

Single

80,000

50,000

500

JCR-A-9R

200 9R

7200V

15.85

3.0

3.0

Single

80,000

50,000

750

JCR-A-12R

230 12R

7200V

15.85

3.0

3.0

Single

80,000

50,000

1,000

JCR-A-18R

390 18R

7200V

15.85

3.0

3.0

Double

80,000

50,000

1,450

JCR-A-24R

450 24R

7200V

15.85

3.0

3.0

Double

80,000

50,000

2,500

7200V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2)
JCR-B-2R

70 2R

8300V

19.25

17.88

-

Single

80,000

50,000

160

JCR-B-3R

100 3R

8300V

19.25

17.88

-

Single

80,000

50,000

250

JCR-B-4R

130 4R

8300V

19.25

17.88

-

Single

80,000

50,000

325

JCR-B-5R

150 5R

8300V

19.25

17.88

-

Single

80,000

50,000

390

JCR-B-6R

170 6R

8300V

19.25

17.88

-

Single

80,000

50,000

500

JCR-B-9R

200 9R

7200V

19.25

17.88

-

Single

80,000

50,000

750

JCR-B-12R

230 12R

7200V

19.25

17.88

-

Single

80,000

50,000

1,000

JCR-B-18R

390 18R

7200V

19.25

17.88

3.31

Double

80,000

50,000

1,450

JCR-B-24R

450 24R

7200V

19.25

17.88

3.31

Double

80,000

50,000

2,500

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

163

Bussmann®

Medium Voltage Fuses and Fuse Links

Medium Voltage for Motor Circuit Protection
Table of Ratings
kV

Code
Reference

Breaking
Capacity (kA)

3.6

WJON6

50

5 6.3 10
16 20 25
31.5 40 50

3.6

WDOH6

50

3.6

WFOH6

50

3.6

WDLSJ

50

3.6

WFLSJ

50

3.6

WDFHO

50

3.6

WFFHO

3.6

WKFHO

5.5

VFNHA

60

5.5

VKNHA

60

7.2

WFNHO

7.2

Dimensions

Current
Rating (A)

Length

Diameter

7.56∑ (192mm)

1.4∑ (35mm)

50 63 80 100 125

7.56∑ (192mm)

2∑ (51mm)

160 200

11.5∑ (292mm)

3∑ (76mm)

50 63 80 100 125

11.5∑ (292mm)

2∑ (51mm)

160 200

11.5∑ (292mm)

3∑ (76mm)

50 63 80 100 125

10∑ (254mm)

2∑ (51mm)

50

160 200

10∑ (254mm)

3∑ (76mm)

50

250 315 355 400

10∑ (254mm)

3∑ (76mm)

2R-6R

15.86∑ (403mm)

3∑ (76mm)

9R-24R

15.86∑ (403mm)

3∑ (76mm)

40

25 31.5 40 50 63
80 100 125 160

15.86∑ (403mm)

3∑ (76mm)

WKNHO

40

200 224 250 315

15.86∑ (403mm)

3∑ (76mm)

7.2

WFMSJ

40

25 31.5 40 50
63 80 125 160

17.40∑ (442mm)

3∑ (76mm)

7.2

WKMSJ

40

200 224 250 315 355

17.40∑ (442mm)

3∑ (76mm)

Dimensional
Standard
BS2692 (TA1)
Interchangeable with
GEC type K2 PA
BS 2692 (TA1)
or DIN 43625
DIN 43625

BS 2692 (TA2)
N. American
Practice

BS2692 (TA4)

DIN 43625

Catalog Code:
kV

Code
Reference

Current
Rating

Recommended Fuse Clips for Medium Voltage Fuses
Clip Dimensions

Part
No.

Fuse
Diameter

A

B

A3354710

2

3.74

1.97

2.00 1.18

4.53

1.50 .39

A3354730

3

4.13

2.44

3.00 1.18

5.63

1.50 .39

C

D

E

F

G

C
A

G

Fuseclips are for single barrel applications only. Are not sold in pairs.

F
D

E

B

1A0065
3” Diameter Clip

9078A67G04
3” Diameter Clip

2 CUP ASSEMBLIES PER PACKAGE.
DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

164

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

E-Rated Medium Volt for Transformers and Feeders
MV055 and MV155
E-Rated Medium Voltage Fuses
Meets E requirements per ANSI C37.46
Meets full range requirements per ANSI C37.40
For Transformer and Feeder Protection
Current Limiting
Voltage Rating: 5.5 kV and 15.5 kV
Interrupting Rating: 50KA Maximum Sym.
Construction: Silver ribbon element surrounded by silica
filler housed in a fiberglass tube and plated endcaps. An
epoxy paint protects the fuse tube from the surrounding
environment.

Electrical Characteristics 5.5kV

Electrical Characteristics 15.5kV
Physical Size
Max.
Clear
Clip
I2t
Length Dia. Center Barrels
2,400
8,000
8,000
11,000
23,000 15.75
2
12
1
31,000
45,000
45,000
90,000
181,000

Part
Number
MV055F1CAX5E
MV055F1CAX7E
MV055F1CAX10E
MV055F1CAX15E
MV055F1CAX20E
MV055F1CAX25E
MV055F1CAX30E
MV055F1CAX40E
MV055F1CAX50E
MV055F1CAX65E

Ampere
Rating
5A
7A
10A
15A
20A
25A
30A
40A
50A
65A

Min.
Melt
I2t
180
850
850
2,070
2,370
4,650
9,490
9,490
13,600
30,700

MV055F1DAX10E
MV055F1DAX15E
MV055F1DAX20E
MV055F1DAX25E
MV055F1DAX30E
MV055F1DAX40E
MV055F1DAX50E
MV055F1DAX65E
MV055F1DAX80E
MV055F1DAX100E

10A
15A
20A
25A
30A
40A
50A
65A
80A
100A

850
2,070
2,370
4,650
9,490
9,490
13,600
30,700
54,600
116,200

MV055F1DAX125E
MV055F1DAX150E
MV055F1DAX175E
MV055F1DAX200E

125A
150A
175A
200A

167,400
600,000
218,700
786,000
227,900 1,100,000 15.75
297,600 1,520,000

MV055F2DAX250E
MV055F2DAX300E
MV055F2DAX350E
MV055F2DAX400E
MV055F2DAX450E

250A
300A
350A
400A
450A

669,600
874,800
911,600
1,190,400
1,555,000

8,000
12,000
23,000
31,000
45,000 15.75
45,000
90,000
181,000
270,000
580,000

2,400,000
3,149,000
4,376,000 15.75
6,071,000
9,796,000

3

12

1

3

12

1

3

12

2

Min.
Melt
I2t
180
850
850
2,070
2,370
4,650
9,490

Physical Size
Max.
Clear
Clip
I2t
Length Dia. Center Barrels
2,900
8,000
8,000
12,000 18.75
2
15
1
23,000
31,000
45,000

Part
Number
MV155F1CBX5E
MV155F1CBX7E
MV155F1CBX10E
MV155F1CBX15E
MV155F1CBX20E
MV155F1CBX25E
MV155F1CBX30E

Ampere
Rating
5A
7A
10A
15A
20A
25A
30A

MV155F1DBX10E
MV155F1DBX15E
MV155F1DBX20E
MV155F1DBX25E
MV155F1DBX30E
MV155F1DBX40E
MV155F1DBX50E
MV155F1DBX65E
MV155F1DBX80E
MV155F1DBX100E

10A
15A
20A
25A
30A
40A
50A
65A
80A
100A

850
2,070
2,370
4,650
9,490
9,490
13,600
30,700
54,600
116,200

8,000
12,000
23,000
31,000
45,000
45,000 18.75
90,000
181,000
270,000
600,000

MV155F2DBX125E
MV155F2DBX150E
MV155F2DBX175E
MV155F2DBX200E

125A
150A
175A
200A

123,000
218,700
314,700
465,100

677,000
1,287,000 18.75
1,689,000
2,405,000

MV155F1DCX65E
MV155F1DCX80E
MV155F1DCX100E
MV155F2DCX125E
MV155F2DCX150E
MV155F2DCX175E
MV155F2DCX200E

65A
80A
100A
125A
150A
175A
200A

30,700
54,600
116,200
123,000
218,700
314,700
465,100

181,000
270,000 21.75
600,000
677,000
1,287,000
1,689,000 21.75
2,405,000

Data Sheet: 6700
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

3

15

1

3

15

2

3

18

1

3

18

2

Data Sheet: 6701

165

Bussmann®

Medium Voltage Fuses and Fuse Links

E-Rated Medium Volt

for Potential & Sm Power Transformers
JCD, JCW, JCE, JCQ, JCI & JCT
Current Limiting
Indicating/Non-Indicating
Plated Ferrules
Voltage Rating: (Max. Design) 2750, 5500,
8300, 15,500
Current Ratings: 1/2E through 10E

Specifications
Buss
Catalog No.

Amperage

Maximum Interrupting Capacity

Maximum
Design Voltage

Construction

Amps (Asym.)

Amps (Sym.)

Dimensions
Length

Diameter

2400V; E-Rated Fuse; Indicating
JCD-⁄Ω™E

0.50E

2750V

Single

100,000

63,000

4.50∑

.80∑

JCD-1E

1.00E

2750V

Single

63,000

40,000

(114mm)

(20.32mm)

JCD-2E

2.00E

2750V

Single

63,000

40,000

JCD-5E

5.00E

2750V

Single

40,000

25,000

2450/5500V; E-Rated Fuse; Non-Indicating
JCW-⁄Ω™E

0.50E

2750V/5500V

Single

60,000

40,000

JCW-1E

1.00E

2750V/5500V

Single

60,000

40,000

JCW-2E

2.00E

2750V/5500V

Single

60,000

40,000

7.312∑

1.563∑

JCW-3E

3.00E

2750V/5500V

Single

60,000

40,000

(185.72mm)

(39.70mm)

JCW-4E

4.00E

2750V/5500V

Single

60,000

40,000

JCW-5E

5.00E

2750V/5500V

Single

60,000

40,000
50,000

5500V; E-Rated Fuse; Non-Indicating
JCE-⁄Ω™E

0.50E

5500V

Single

60,000

JCE-1E

1.00E

5500V

Single

60,000

50,000

JCE-2E

2.00E

5500V

Single

60,000

50,000

5.625”

.81”

JCE-3E

3.00E

5500V

Single

60,000

50,000

(142.88mm)

(20.32mm)

JCE-4E

4.00E

5500V

Single

60,000

50,000

JCE-5E

5.00E

5500V

Single

60,000

50,000

5500V; E-Rated Fuse; Indicating
JCQ-⁄Ω™E

0.50E

5500V

Single

130,000

80,000

JCQ-1E

1.00E

5500V

Single

130,000

80,000

JCQ-1⁄Ω™E

1.50E

5500V

Single

130,000

80,000

1.6∑

JCQ-3E

3.00E

5500V

Single

130,000

80,000

(40.64mm)

JCQ-5E

5.00E

5500V

Single

130,000

80,000

JCQ-10E

10.00E

5500V

Single

130,000

80,000

9.5∑
(241.3mm)
9.44∑
(239.78mm)

8300V; E-Rated Fuse; Indicating
JCI-⁄Ω™E

0.50E

8300V

Single

130,000

80,000

JCI-3E

3.00E

8300V

Single

130,000

80,000

JCI-5E

5.00E

8300V

Single

130,000

80,000

JCI-10E

10.00E

8300V

Single

130,000

80,000

9.5∑
(241.3mm)
1.6∑

12.88∑
(327.15mm)

(40.64mm)

15,500V; E-Rated Fuse; Indicating
JCT-⁄Ω™E

0.50E

15500V

Single

130,000

80,000

JCT-1E

1.00E

15500V

Single

130,000

80,000

JCT-1⁄Ω™E

1.50E

15500V

Single

130,000

80,000

1.6∑

JCT-3E

3.00E

15500V

Single

130,000

80,000

(40.64mm)

JCT-5E

5.00E

15500V

Single

130,000

80,000

JCT-10E

10.00E

15500V

Single

130,000

80,000

12.93∑
(328.42mm)
17.5∑
(444.5mm)

Fuse clip for 1.6∑ Diameter Fuses - 1A0835.
Fuse clip for .81∑ Diameter Fuses - 1A1837.

Data Sheet: 6002

166

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

E-Rated Fuses for Trans. & Feeder Protection
E-Rated
Current Limiting
Blown Fuse Indication
Construction: Plated Ferrules
Voltage Ratings: (Max. Design): 2,750, 5,500, 8,300,
15,500V
Current Ratings: ⁄Ω™E through 750E

Specifications
Buss
Catalog No.

Amperage

Maximum Interrupting Capacity

Maximum
Design Voltage

Construction

Amps. (Asym.)

Amps. (Sym.)

Dimensions
Length

Diameter

9.19∑
(233.38mm)

2∑
(50.8mm)

9.5”

2.1”

10.81∑
(276.35mm)

3∑
(76.2mm)

11.19∑
(284.18mm)

2∑
(50.8mm)

2400V; E-Rated; Indoor/Enclosure
JCX-⁄Ω™E

⁄Ω™E

2750V

Single

60,000

40,000

JCX-1E

1E

2750V

Single

60,000

40,000

JCX-2E

2E

2750V

Single

60,000

40,000

JCX-3E

3E

2750V

Single

60,000

40,000

JCX-5E

5E

2750V

Single

60,000

40,000

JCX-7E

7E

2750V

Single

60,000

40,000

JCX-10E

10E

2750V

Single

60,000

40,000

JCX-15E

15E

2750V

Single

80,000

50,000

JCX-20E

20E

2750V

Single

80,000

50,000

JCX-25E

25E

2750V

Single

80,000

50,000

JCX-30E

30E

2750V

Single

80,000

50,000

JCX-40E

40E

2750V

Single

80,000

50,000

JCX-50E

50E

2750V

Single

80,000

50,000

JCX-65E

65E

2750V

Single

80,000

50,000

JCX-80E

80E

2750V

Single

80,000

50,000

JCX-100E

100E

2750V

Single

80,000

40,000

JCX-125E

125E

2750V

Single

80,000

50,000

JCX-150E

150E

2750V

Single

80,000

50,000

JCX-200E

200E

2750V

Single

80,000

50,000

JCX-225E

225E

2750V

Single

80,000

50,000

JCX-250E/280X

250E/280X

2750V

Double

80,000

50,000

JCX-300E/325X

300E/325X

2750V

Double

80,000

50,000

JCX-350X

350X

2750V

Double

80,000

50,000

JCX-400X

400X

2750V

Double

80,000

50,000

JCX-450X

450X

2750V

Double

80,000

50,000

5500V; E-Rated; Indoor/Enclosure
JCY-⁄Ω™E

⁄Ω™E

5500V

Single

60,000

40,000

JCY-1E

1E

5500V

Single

60,000

40,000

JCY-2E

2E

5500V

Single

60,000

40,000

JCY-3E

3E

5500V

Single

60,000

40,000

JCY-5E

5E

5500V

Single

60,000

40,000

JCY-7E

7E

5500V

Single

60,000

40,000

JCY-10E

10E

5500V

Single

60,000

40,000

JCY-15E

15E

5500V

Single

60,000

40,000

JCY-20E

20E

5500V

Single

60,000

40,000

JCY-25E

25E

5500V

Single

60,000

40,000

Contact Bussmann for the latest product information on E-Rated Fuses for Transformer and feeder protection.
Recommended Fuse Clips: 3 - 1A0065, 9078A67G04, A3354730

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

167

Bussmann®

Medium Voltage Fuses and Fuse Links

E-Rated Fuses for Trans. & Feeder Protection
Specifications
Buss
Catalog No.

Amperage

Maximum Interrupting Capacity

Dimensions

Maximum
Design Voltage

Construction

Amps. (Asym.)

Amps. (Sym.)

Length

Diameter

17.81∑
(452.4mm)

3∑
(76.2mm)

12.88∑
(327.0mm)

2.1∑
(53.34mm)

17.88”
(454.15mm)

3∑
(76.20mm)

28.81∑
(731.77mm)

4”
(101.60mm)

15.51∑
(393.95mm)

2.1∑
(53.34mm)

17.88∑
(454.15mm)

3∑
(76.2mm)

15.88∑
(403.2mm)

3∑
(76.2mm)

5500V; E-Rated; Indoor/Enclosure
JCU-10E

10E

5500V

Single

80,000

50,000

JCU-15E

15E

5500V

Single

80,000

50,000

JCU-20E

20E

5500V

Single

80,000

50,000

JCU-25E

25E

5500V

Single

80,000

50,000

JCU-30E

30E

5500V

Single

100,000

63,000

JCU-40E

40E

5500V

Single

100,000

63,000

JCU-50E

50E

5500V

Single

100,000

63,000

JCU-65E

60E

5500V

Single

100,000

63,000

JCU-80E

80E

5500V

Single

100,000

63,000

JCU-100E

100E

5500V

Single

100,000

63,000

JCU-125E

125E

5500V

Single

100,000

63,000

JCU-150E

150E

5500V

Single

100,000

63,000

JCU-175E

175E

5500V

Single

100,000

63,000

JCU-200E

200E

5500V

Single

100,000

63,000

JCU-250E

250E

5500V

Single

100,000

63,000

JCU-300E

300E

5500V

Double

100,000

63,000

JCU-350E

350E

5500V

Double

100,000

63,000

JCU-400E

400E

5500V

Double

100,000

63,000

JCU-450E

450E

5500V

Double

100,000

63,000

JCU-600E

600E

5500V

Double*

80,000

50,000

JCU-750E

750E

5500V

Double*

80,000

50,000

8300V; E-Rated; Indoor/Enclosure
JCZ-15E

15E

8300V

Single

80,000

50,000

JCZ-20E

20E

8300V

Single

80,000

50,000

JCZ-25E

25E

8300V

Single

80,000

50,000

JCZ-30E

30E

8300V

Single

80,000

50,000

JCZ-40E

40E

8300V

Single

80,000

50,000

JCZ-50E

50E

8300V

Single

80,000

50,000

JCZ-65E

65E

8300V

Single

80,000

50,000

JCZ-80E

80E

8300V

Single

80,000

50,000

JCZ-100E

100E

8300V

Single

80,000

50,000

JCZ-125E

125E

8300V

Single

80,000

50,000

JCZ-150E

150E

8300V

Single

80,000

50,000

JCZ-200E

200E

8300V

Double

80,000

50,000

JDZ-20E
JDZ-25E
JDZ-30E
JDZ-40E
JDZ-50E
JDZ-65E
JDZ-80E
JDZ-100E
JDZ-125E

20E
25E
30E
40E
50E
65E
80E
100E
125E

8300V
8300V
8300V
8300V
8300V
8300V
8300V
8300V
8300V

Single
Single
Single
Single
Single
Single
Double
Double
Double

80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000
80,000

50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000
50,000

Recommended Fuse Clips: 3 - 1A0065, 9078A67G04, A3354730
General Notes:
1. All fuses are fitted with a striker pin which can be used for indication or tripping purposes.
2. The fuses are suitable for use either indoors or outdoors.
3. These fuses are interchangeable with corresponding fuses produced by most other leading North American manufacturers.

Contact Bussmann for the latest product information on E-Rated Fuses for Transformer and feeder protection.
*Bolt on mounting

168

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

Medium Voltage DIN Distribution Fuses
DIN Dimension Fuses To Spec. DIN 43625
This product group covers current limiting fuses with dimensions to DIN 43625 and performance in compliance with IEC
282-1.
Striker Characteristics
The spring operated striker pin has a travel and energy output
in compliance with the requirements of DIN 43625 and IEC
282-1.
Current Ratings
These are in accordance with the R10 and, in some cases,
the R20 series of preferred numbers.
Table of Ratings and Dimensions
kV

Dimensions Inches and mm
Code Ref.
Current Rating
Diameter ≈ Length
ADOSJ
6.3, 16, 20, 25, 31.5, 40,
2.00∑ ≈ 7.56∑
WDOSJ
50, 63, 80, 100, 125
51 ≈ 192
____________________________________________________
______________________________
WFOSJ

160, 200

3.00∑ ≈ 7.56∑

ADLSJ

6.3, 10, 16, 20, 25, 31.5,

2.00∑ ≈ 11.50∑

DIN Series

IR
RMS Symm

3.6/7.2

76 ≈ 192
____________________________________________________________________________________________________
3.6

50KA

WDLSJ
40, 50, 63, 80, 100, 125
51 ≈ 292
____________________________________________________
______________________________

WFLSJ
160
10/12
WFLSJ
200
3.00∑ ≈ 11.50∑
WKLSJ
250
76 ≈ 292
WKLSJ
315, 400
_________________________________________________________________________________________________________________________
______
SDLSJ

6.3, 10, 16, 20, 25, 31.5

2.00∑ ≈ 11.50∑

SDLSJ
40, 50, 63
51 ≈ 292
____________________________________________________
______________________________
7.2

SFLSJ
80
10/12
SFLSJ
100
3.00∑ ≈ 11.50∑
SFLSJ
125
76 ≈ 292
SFLSJ
160
____________________________________________________________________________________________________
WKMSJ

200

3.00∑ ≈ 17.41∑

40KA

20/24

WKMSJ
250, 315, 355
76 ≈ 442
_________________________________________________________________________________________________________________________
______

12

SDLSJ
6.3, 10, 16, 20, 25
2.00∑ ≈ 11.50∑
SDLSJ
31.5, 40
51 ≈ 292
SDLSJ
50,
63
__________________________________________________________________________________

10/12
50KA
SFLSJ
63, 80
3.00∑ ≈ 11.50∑
SFLSJ
100
76 ≈ 292
SKLSJ
125, 160, 200
_________________________________________________________________________________________________________________________
______
SDLSJ
6.3, 10, 16
2.00∑ ≈ 11.50∑
SDLSJ
20, 25
51 ≈ 292
SDLSJ
40
__________________________________________________________________________________
17.5

10/12
SFLSJ
31.5
3.00∑ ≈ 11.50∑
SFLSJ
40, 50
76 ≈ 292
____________________________________________________________________________________________________
SDMSJ
6.3, 10, 16
2.00∑ ≈ 17.41∑
SDMSJ
20, 25, 31.5
51 ≈ 442
SDMSJ
40
__________________________________________________________________________________

35.5KA

SFMSJ
50
3.00∑ ≈ 17.41∑
20/24
SFMSJ
63, 80
76 ≈ 442
_________________________________________________________________
______________________________
________________
SFMSJ
100
3.00∑ ≈ 17.41∑
25KA
15.5
SKMSJ
125
76 ≈ 442
_________________________________________________________________________________________________________________________
______

24

SDMSJ
6.3, 16
2.00∑ ≈ 17.41∑
SDMSJ
20, 25, 31.5
51 ≈ 442
SDMSJ
40
(24kv
application
only)
__________________________________________________________________________________

20/24
50KA
SFMSJ
40, 50
3.00∑ ≈ 17.41∑
SFMSJ
63
76 ≈ 442
SFMSJ
71 (24kv application only)
_________________________________________________________________________________________________________________________
______
SDQSJ
36

6.3, 10, 16, 20, 25, 31.5

2.00∑ ≈ 21.16∑

3.15
51 ≈ 442
____________________________________________________
______________________________
SFQSJ

31.5, 40, 50, 56

3.00∑ ≈ 21.16∑

30/36

35.5KA

76 ≈ 537
_________________________________________________________________________________________________________________________
______
Recommended Fuseclips for DIN Style Fuses: Bussmann Part Number 270303

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

169

Bussmann®

Medium Voltage Fuses and Fuse Links

Potential Transformer Fuses
These are a range of fuses with low current rating, for use
with voltage transformers or operating transformers to provide
isolation of the associated system in the event of faults in the
transformer circuit.

“AB” & “AM” Series
kV

Code
Reference

3.6

ABWNA

Current Ratings
3.15, 6.3

Type

Length

AB

5.6∑

Diameter

IR

1∑

3.6

ABCNA

3.15, 6.3, 10

AB

7.69∑

1∑

5.5

ABWNA

0.5E, 1E, 2E, 3E, 5E

AB

5.6∑

1∑

5.5

AMWNA

0.5E, 1.0E, 2.0E, 3.0E, 4.0E, 5.0E

AM

5.6∑

7.2

ABWNA

3.15, 6.3

AB

5.6∑

50KA

.81∑
1∑

7.2

ABCNA

3.15, 6.3

AB

7.69∑

1∑

12.0

ABCNA

3.15

AB

7.69∑

1∑

45KA

15.5

ABFNA

3.15

AB

10.00∑

1∑

32KA

17.5

ABGNA

3.15

AB

14.13∑

1∑

35KA

24.0

ABGNA

3.15

AB

14.13∑

1∑

25KA

36.0*

ABGNA

3.15

AB

14.13∑

1∑

31.5KA

Recommended fuse clip for 1∑ diameter fuses – A3354705.

“CAV” Series
Code
Reference

kV

Current Ratings

Length

3.6

CAV

2

5.5

CAV

15E

7.375∑

5.5

CAVH

0.5E, 1E, 2E

7.375∑

7.2

CAV

2, 10

8.66∑

12

CAV

2

15.5

CAV

0.5E, 1E, 2E, 3E, 7E

12.87∑

15.5

CAVH

0.5E, 1E, 2E

12.87∑

17.5

CAV

2, 4, 6, 10

24

CAV

2, 3, 4

13.39∑

36

CAV

2, 4

17.32∑

36

CAVH

2

17.32∑

38

CAV

4E

17.32∑

38

CAVH

0.5E, 1E, 2E

17.32∑

Diameter

IR

1.63∑

40KA

8.66∑

8.66∑

8.66∑

*For clean indoor applications only.
Type CAVH are fitted with a striker pin for indication.

Catalog Code:

kV

Code
Reference

Current
Rating

Recommended Fuse Clips: 1 dia. - A3354705
1.63” dia. - 1A0835
.81 dia. - 1A1837
Contact Bussmann for complete specifications on Potential Transformer Fuses

170

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

Medium Voltage, Fast Acting Fuses
Test Specifications
Catalog
Number

HVA, HVB, HVJ, HVL, HVR, HVT, HVU,
HVW & HVX

Load

Opening Time

HVA
HVB
HVJ
HVL

110%
135%

4 Hours (min.)
1 Hour (max.)

HVR
HVT
HVU
HVW
HVX

100%
150%

4 Hours (min.)
1 Hour (max.)

Non-Time Delay
Ampere Ratings:
Voltage Rating: 1000 to 10,000V
HVA (1000 Volts) (Max. S.C. 20KW dc, 30KVA ac)
Length
Amps
⁄Ω¡§
⁄Ω•
⁄Ω¢
⁄Ω¡º
¤Ω¡º
‹Ω¡º
‹Ω•
⁄Ω™

‹Ω¢
1
1⁄Ω™
2
3
4
6
10

Dia.

In.

mm

0.41∑

3∑

76.1

*Wt./100
Lbs.
Kg

2

0.91

4528, 4529, 4530 & 2960
Fuseblocks
Voltage Rating: 1000 to 10,000V

HVB (2500V) (Max. S.C. 20KW dc, 30KVA ac)
⁄Ω™
‹Ω¢
1

1⁄Ω™
2
3

0.41∑

4.5∑

114.2

3

1.36

HVJ (5000V) (Max. S.C. 20KW dc, 30KVA ac)
⁄Ω¡§
⁄Ω•
⁄Ω¢
⁄Ω™
‹Ω¢
1

1⁄Ω™
2
4
6
10
—

HVA
HVR
0.81∑

5∑

126.9

9

4.08

HVJ

1
1⁄Ω™
2
3

0.81∑

10∑

253.8

HVU
15

6.80

3
4
5

0.41∑

3∑

76.1

HVL
HVX

Block
Cat.
No.
4528
4529
4530
2960

Use #8 screws on blocks 4528 and 4529.
Use #10 screws on blocks 4530 and 2960.

HVR (1000V) (Max. S.C. kVA-500 ac only)
⁄Ω™
1
2

HVB
HVT

HVL (10,000V) (Max. S.C. 20KW dc, 30KVA ac)
⁄Ω¡§
⁄Ω•
⁄Ω¢
⁄Ω™

For
Fuse
Sym.

3

1.36

2

0.91

4

1.81

19

8.62

36

16.33

HVW (1200V) (Max. S.C. kVA-12,000 ac only)
—
1
2
—

3
4
5
8

0.41∑

2.25∑

57.1

HVT (2500V) (Max. S.C. kVA-1250 ac only)
⁄Ω™
1
2

3
5
—

0.41∑

4.5∑

114.2

HVU (5000V) (Max. S.C. kVA-2500 ac only)
⁄Ω™
1
2

3
4
5

0.81∑

5∑

126.9

HVX (10,000V) (Max. S.C. kVA-5,000 ac only)
⁄Ω™
1

3
5

0.41∑

10.0∑

253.8

*Shipping.
Carton quantity: 10.

Data Sheet: 6003
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

171

Bussmann®

Medium Voltage Fuses and Fuse Links

Medium Voltage — BS2692-1 Fuses
General Guide to the Selection of HV Fuse Links, used in oilfield switchgear. For use in the Primary Circuit of Three
Phase 50 Hz Transformers
Transformer Primary Voltage
11kV

Transformer
kVA
200
250
300/315
400
500
630
750/800
1000
1250
1600

3.3kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV

OEFMA 63
OEFMA 80
OEFMA 100
OEFMA 125
OEFMA 160
OEFMA 200
OLGMA 250
OLGMA 250*
—
—

6.6kV

ESI 12-8 Ref.

12kV OEFMA 31.5
12kV OEFMA 40
12kV OEFMA 50
12kV OEFMA 63
12kV OHFMA 71
7.2kV OEFMA 100
7.2kV OHGMA 125
7.2kV OHGMA 140
7.2kV OHGMA 160*
—

01
—
02
—
03
—
04
05
—
—

Fuse Rating
12kV
12kV
12kV
12kV
12kV
12kV
12kV
12kV
12kV
12kV

OEFMA 25
OEFMA 25
OEFMA31.5
OEFMA 40
OEFMA 50
OEFMA 63
OHFMA 80
OHGMA 90**
OHGMA 100
OLGMA 125*

13.8kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV
15.5kV

OEFMA 16
OEFMA 20
OEFMA 25
OEFMA 31.5
OEFMA 40
OEFMA 50
OEFMA 63
OHGMA 71
OHGMA 90
OLGMA 100*

This selection table has been based upon the following criteria:
1. Withstand against magnetizing inrush current taken as 12 times full-load current for 0.1 second.
2. Withstand against 150% permissible overload current. Recommendations marked with asterisks have the following significance:*Limited to permissible overloads of 130%.
**Permits use of a 12kV OHFMA 80A fuse with a 100kVA transformer where permissible overload does not exceed 130%.
3. For 6.6kV systems, 12kV fuse links are recommended where possible in the interests of standardization.
4. Wherever possible, 10 inch long FO1 fuse links are offered rather than equivalent 14 inch FO2 types.
5. The above recommendations are not generally applicable to transformers feeding motor circuits with starting currents in excess of the transformer full load current. In this event, please consult Bussmann.

Code References in Table
Letter
Reference
Explanation
1st
Type
O = Oiltight
2nd
Diameter
E, H, L = 63.5 mm
3rd
Length
F = 254 mm, G = 359 mm
4th
Striker
M = As specified in BS 2692 table 11.
5th
Tags
A = none, i.e. plain caps

Table of Preferred Ratings
Rated kV

Code
Reference

Dimensional
Ref. BS 2692

Current Ratings
(amps)

Breaking
Capacity (kA)

3.6

OEFMA

FO1

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63,
80, 100, 125, 160, 200

50

3.6
3.6

OEGMA
OLGMA

FO2
FO2

100, 125, 160, 200
250

50
50

7.2
7.2

OEFMA
OHGMA

FO1
FO2

80, 100, 112
125, 140, 160

45
45

12.0
12.0
12.0
12.0

OEFMA
OHFMA
OHGMA
OLGMA

FO1
FO1
FO2
FO2

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
71, 80
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 71, 80, 90, 100
125

40
40
40
40

15.5
15.5
15.5

OEFMA
OHGMA
OLGMA

FO1
FO2
FO2

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
71, 80, 90
100

40
40
40

17.5

OHGMA

FO2

6.3, 10, 16, 20, 25, 31.5, 40, 50, 63, 80

35

24.0

OEGMA

FO2

6.3, 10, 16, 20, 25, 31.5, 40, 50

25

Contact Bussmann for complete specifications on Medium Voltage Fuses

172

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Medium Voltage Fuses and Fuse Links

Medium Voltage Fuse Links
High-Surge Type H Fuse Links
High-surge, Type H fuse links are manufactured in ratings of
1, 2, 3, 5, and 8A. They have been developed principally for
primary fusing of small-sized transformers. Type H links are
manufactured in the universal buttonhead design.
Type N Fuse Links
Type N fuse links conform to previous NEMA standards and
have been superseded by Type K and T links. Type N fuse
links are manufactured in the universal button design in ratings
of 5 through 200A for use in NEMA standard dimensioned
cutouts rated through 27 kv.
Catalog Data-EEI-NEMA and High-Surge Universal Tin
Element Fuse Links for Cutouts. Rated to 27kV

EEI-NEMA Type K and T Fuse Links
These fuse links afford effective overcurrent protection to systems and equipment. In addition to apparatus protection, they
can be coordinated with other overcurrent protective devices
for sectionalizing in order to isolate feeder branches.
Catalog Data-EEI-NEMA and High-Surge Universal Tin
Element Fuse Links for Cutouts. Rated to 27kV
Link
Amps

Type H
(High
Surge)

EEI-Nema
Type K
(Fast)

EEI-Nema
Type T
(Slow)

Carton Data
Weight
Qty.

Lbs.

Kg's.

Non-Removable Button-Head For Standard Open Or Enclosed Cutouts

1
FL11H1
FL11K1
FL11T1
_______________________________________________
2
FL11H2
FL11K2
FL11T2
_______________________________________________

25
2
0.91
3
FL11H3
FL11K3
FL11T3
_______________________________________________
5
FL11H5
FL11K5
FL11T5
____________________________________________________________________
__
6
—
FL11K6
FL11T6
_______________________________________________
8
FL11H8
FL11K8
FL11T8
_______________________________________________
10
—
FL11K10
FL11T10
_______________________________________________
12
—
FL11K12
FL11T12
_______________________________________________

25

2

0.91

15
—
FL11K15
FL11T15
_______________________________________________
20
—
FL11K20
FL11T20
_______________________________________________
25
—
FL11K25
FL11T25
____________________________________________________________________
__
30
—
FL11K30
FL11T30
_______________________________________________

Link
Amps

Type H
(High
Surge)

EEI-Nema
Type K
(Fast)

Carton Data

EEI-Nema
Type T
(Slow)

Weight
Qty.

Lbs.

Kg's.

Removable Button-Head For Cutouts Requiring Removable-Button
Links*
1
—
FL3K1
FL3T1
_______________________________________________
2
—
FL3K2
FL3T2
_______________________________________________
3
—
FL3K3
FL3T3
_______________________________________________
5
—
FL3K5
FL3T5
_______________________________________________
6
—
FL3K6
FL3T6
_______________________________________________
8
—
FL3K8
FL3T8
_______________________________________________

25

1.81

0.82

10
—
FL3K10
FL3T10
_______________________________________________
12
—
FL3K12
FL3T12
_______________________________________________
15
—
FL3K15
FL3T15
_______________________________________________
20
—
FL3K20
FL3T20
_______________________________________________
25
—
FL3K25
FL3T25
____________________________________________________________________
__
30
—
FL3K30
FL3T30
_______________________________________________
40
—
FL3K40
FL3T40
25
3.44
1.56
_______________________________________________
50
—
FL3K50
FL3T50
____________________________________________________________________
__
65
—
FL3K65
FL3T65
_______________________________________________
80
—
FL3K80
FL3T80
15
3.63
1.65
_______________________________________________
100
—
FL3K100
FL3T100
____________________________________________________________________
__
140
—
FL3K140
FL3T140
10
7.63
3.46
_______________________________________________
200
—
FL3K200
FL3T200
____________________________________________________________________
__

40
—
FL11K40
FL11T40
25
4
1.82
_______________________________________________
50
—
FL11K50
FL11T50
______________________________________________________________________

*Adapter-type removable-button links with ferrule adapter to convert to double-leader links
are available in K and T types. Order by description.

65
—
FL11K65
FL11T65
_______________________________________________
80
—
FL11K80
FL11T80
_______________________________________________

Catalog Data—EEI-NEMA Type K Universal Silver-Element
Fuse Links for Cutouts Rated through 27kV

15

5
2.27
_______________
5.5
2.49
_______________

100
—
FL11K100
FL11T100
6
2.72__
____________________________________________________________________
140
—
FL11K140
FL11T140
7
3.17
_______________________________________________ 10
_______________
200
—
FL11K200
FL11T200
10
4.53
______________________________________________________________________

Link
Rating
Amps

Carton Data
EEI-Nema
Type K

Weight
Qty.

Lbs.

Kg's.

Non-Removable Button-Head For Standard Open Or Enclosed
Cutouts
8
FL12K8
___________________________
_
10
FL12K10
___________________________
_
12
FL12K12
___________________________
_
15
FL12K15
___________________________
_

25

2

0.91

25
FL12K25
____________________________________________________________________
__
50
FL12K50
25
3
1.34
____________________________________________________________________
__

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

173

Page 174
BLANK
(Do NOT Print)

Bussmann®

Telpower® DC Power Protection Systems

Telpower® Compact Fused Disconnect Switch

TPC & TPCDS

TPC & TPCDS
TPCDS - Telpower® Compact Fused Disconnect Switch
TPC - Telpower® Compact Fuse - Current Limiting
Ampere Ratings: 3-125A
Available Ratings: 3, 4, 5, 6, 7, 8, 10, 12, 15, 20, 25, 30,
40, 50, 60, 75, 90, 100, 125A
Voltage Rating: 80Vdc
Interrupting Rating: 100,000A
Agency Information:
UL Recognized (investigated to UL 1801) as a
disconnect switch for the interruption of load current
by means of withdrawing the fuse pullout.
Recognized to U.S. and Canadian requirements under the
component recognition program of Underwriters
Laboratories Inc.
Files E219046 and E56412.
General Information:
• Fusible solution for replacement of existing DC Telecom
circuit breakers.
• Compact size fused disconnect switch.
• AmpColor ID™ System for easy fuse replacement.
• Available in two disconnect switch profiles in addition to a
variety of terminal styles.
• Local and remote open fuse indication.
Local alarm indication provided by LED on TPC fuse.
• Remote alarm terminal available in three positions
common to DC circuit protection devices.
• Recommended .75 inch center-to-center product spacing.
• Current-limiting capability
• Complete system coordination capability.
• Highest interrupting rating (100,000A) available
for DC circuit protection of this footprint.
• No venting of arc or molten metals and gases during
opening.
• Fuse material: Black thermoplastic, UL rated 94 V-O,
170° C RTI.
• Housing material: Black thermoplastic, UL rated 94 V-O,
120° C RTI.

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer
to Data Sheet: 8002 or contact Bussmann Application
Engineering for more information.

Look for Telpower® BLUE™ fuses exclusively from
Cooper Bussmann.

Catalog Number
TPC-3
TPC-4
TPC-5
TPC-6
TPC-7
TPC-8
TPC-10
TPC-12
TPC-15
TPC-20
TPC-25
TPC-30
TPC-40
TPC-50
TPC-60
TPC-75
TPC-90
TPC-100
TPC-125
TPCDS-BBE-1
TPCDS-BBE-2
TPCDS-BBE-3
TPCDS-BBM-1
TPCDS-BBM-2
TPCDS-BBM-3
TPCDS-BSE-1
TPCDS-BSE-2
TPCDS-BSE-3
TPCDS-BSM-1
TPCDS-BSM-2
TPCDS-BSM-3
TPCDS-SSE-1
TPCDS-SSE-2
TPCDS-SSE-3
TPCDS-SSM-1
TPCDS-SSM-2
TPCDS-SSM-3
TPCDS-D-BC1*
TPCDS-D-BC2*
TPCDS-D-CC1*
TPCDS-D-SEC1*
TPCDS-D-SEC2*
TPCDS-D-SMC1*
TPCDS-D-SMC2*

Description
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Fuse
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect
Compact Disconnect

Ampere Rating
3A
4A
5A
6A
7A
8A
10A
12A
15A
20A
25A
30A
40A
50A
60A
75A
90A
100A
125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A
3-125A

*Not investigated to Canadian Requirements.

Data Sheet: 5023
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

175

Bussmann®

Telpower® DC Power Protection Systems

Telpower® Miniature Fused Disconnect Switch

TPM & TPMDS

TPM & TPMDS

General Information:

TPMDS - Telpower® Miniature Fused Disconnect Switch
TPM - Telpower® Miniature Fuse - Current Limiting
Ampere Ratings: 3-30A
Voltage Rating: 80Vdc
Interrupting Rating: 20,000A
Agency Information:
UL Recognized (investigated to UL 1801) as a
disconnect switch for the interruption of load current
by means of withdrawing the fuse pullout.
Recognized to U.S. and Canadian requirements under the
component recognition program of Underwriters
Laboratories Inc.
Files E219046 and E56412.

• Smallest and most versatile fused disconnect
switch available.
• Small size allows for assembly into 1 U (1.75 inch /
44.5 mm) panel.
• AmpColor ID™ System for easy fuse replacement.
• Switch design provides for easy panel mounting by single
captive 4-40 (M3) nut and panel notch integral to switch
footprint.
• Local and remote open fuse indication. Local alarm
indication provided by LED on TPM fuse.
• Current-limiting capability
• Complete system coordination capability
• Load connection: 1/4 inch quick-connect or bolted
connection with 10-32 (M5) captive nut.
• Line connection: 1/4 inch quick-connect or screw
connection with clearance hole for #10 (M5) bolt.
• Maximum alarm circuit current: 20 mA
• Materials:
Fuse housing - black thermoplastic, UL 94 V-0, 170ºC RTI
Switch housing - black thermoplastic, UL 94 V-0, 140ºC RTI

Catalog Number
TPM-3
TPM-4
TPM-5
TPM-6
TPM-7
TPM-8
TPM-10
TPM-12
TPM-15
TPM-20
TPM-25
TPM-30
TPMDS-E
TPMDS-M

Description
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Fuse
Miniature Disconnect, English
Miniature Disconnect, Metric

Ampere Rating
3A
4A
5A
6A
7A
8A
10A
12A
15A
20A
25A
30A
3-30A
3-30A

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer
to Data Sheet: 8002 or contact Bussmann Application
Engineering for more information.

TPM Alarm Schematic

NOTES:
1. The resistance, R, must be provided by the end-user
to limit the alarm output current to a maximum of
20 mA. The value, R, should be calculated using the
system voltage value.
If remote alarm functionality is not required,
the END-USER CIRCUITRY must still be supplied
to provide a resistive path to the return for the
local alarm to properly function.
2. The fuse is polarized to maintain proper orientation with
the switch housing. The line and load terminals are
identified on the switch housing.

•

Look for Telpower® BLUE™ fuses exclusively from Cooper Bussmann.

Data Sheet: 5022

176

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Telecommunications Protection

Fused Disconnect Switch

TP15914
4 Pole Disconnect Switch and TPA Series Fuses
Ampere Rating: 50A per pole
Voltage Rating: 145Vdc
Agency Information:
UL recognized as a disconnect switch for interruption of
load current by means of withdrawing the fuse carrier.
UL recognized as a component for telecommunication
power distribution equipment (UL category QPQYZ).
UL recognized fuses for branch circuit protection.
CSA component acceptance for the system.
Material: UL rated 94V-0, 140°C rated
Fuse
Fuse Type
Current
Voltage
Interrupting

TPA
3, 5, 10, 15, 20, 25, 30, 40, 50
170Vdc
100 kA

• Front access load and line connection standard—double
lug load connections 8 AWG wire.
• Recognized branch circuit protection device.
• Modular design—4 poles per module up to four modules
banked together.
• Ease of installation—Connection directly to bus bar.
• Reduces external wiring—per pole.
• LED alarm signaling (LED current 30mA max.).
• Blown fuse indication.
• Alarm test probe point, to allow on-site checking of alarm
circuitry.
• Snap into alarm bus.
• Bi-polar LED provides capability for both –48V DC
and +24V DC applications.
• Fuse presence indication.
• Fuse orientation rejection feature.
• Totally enclosed module.
• Spare fuseholders: Part No. 5TPH and TPSFH-A
• Remote alarm.
• Contact Bussmann for options on standard module
(Hardware, Color, Front line connection, Mounting bezel).
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

TPA-B
20, 25
65Vdc
20 kA

UL Recognized, Guide JFHR2, File E56412
CSA Certified, Class 1422-30, File 53787
Dimensional Data
MM
Inches

76.07
3.0

TOP

Data Sheet: 5011
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

177

Telpower® DC Power Protection Systems

Bussmann®

Fused Disconnect Switch & TPA Fuses

TP15900-4
4-Pole Disconnect Switch
For use with Telpower fuses Type TPA & TPA-B.
Electrical Ratings: 40A per pole at 145Vdc
50A per pole at 80Vdc
Agency Information:
UL Recognized as a disconnect switch for interruption of
load current by means of withdrawing the fuse carrier.
UL Recognized as a component for telecommunication
power distribution equipment (UL category QPQY2).
UL Recognized fuses for branch circuit protection.
CSA Component Acceptance for the system.
General Information:
• Ease of installation - connection directly to bus bar.
• Reduces external wiring per pole.
• LED alarm signaling (LED current 30mA max.).
• Local and remote open-fuse indication.
• Alarm test probe point, to allow on-site checking of alarm
circuitry.
• Fuse presence indication.
• Fuse orientation rejection feature.
• Rear accessibility for line and load terminations.
Material: UL rated 94V-0, 140°C rated
®

Catalog Numbers
TP15900-4
TP15900-41

DC Power Distribution Indicating Fuses
Ampere Rating: TPA: 3, 5, 10, 15, 20, 25, 30, 40, 50
TPA-B: 20, 25, 30
Voltage Rating: TPA, 170 Vdc; TPA-B, 65 Vdc
Interrupting Rating: TPA, 100 kA; TPA-B, 20 kA
Agency Information:
UL Recognized, Guide JFHR2, File E56412
CSA Certified, Class 1422-30, File 53787
Construction:
• Silver-plated brass ferrules and indicator pin on TPA 3-15
and TPA-B. Tin-plated brass on TPA 20-50 on indicator
end.
• Glass melamine tube.
• Spare fuseholders: 5 position holder; 5TPH;
6 position holder; TPSFH-AS
Dimensional Data
mm
inches

Split Alarm, Split Line

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 5001

TPA & TPA-B

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 5012

Dimensional Data

178

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Telpower® DC Power Protection Systems

Bussmann®

Fused Disconnect Switch

TPS
Ampere Ratings: 1 to 70A.
Voltage Rating: 170Vdc
Agency Information:
UL Recognized, Guide JFHR2, File E56412
Catalog Numbers

15800
Fused Disconnect Switch
Ampere Ratings: 3 to 70A.
Voltage Rating: 60Vdc
Agency Information:
UL Recognized, Guide QPQY2, File E97649
UL Withstand Rating: 100,000A,
Catalog Numbers
15800-R-200

Rear Access Panel Mounting

15800-F-200

Front Access Panel Mounting

• For use with the following fuses only:
Main: Telpower® TPS 3 to 70 Amp
Alarm: Bussmann GMT-A only (page 183).
Recommend GMT-X Cover (page 183).
• Alarm output with wire wrap terminal or connection to .063”
thick common alarm bus.
• Thermoplastic housing material U.L. rated
94V-0, 150°C.
• Spare alarm and power fuse compartment.
• Mounting hardware included.
• Spare fuseholders:
for TPS fuses (TPSFH-AS);
for GMT fuses (TPSFH-T), see page 196.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data
15800-R-200

TPS-1
TPS-1L
TPS-2
TPS-2L
TPS-3
TPS-3L
TPS-5
TPS-5L
TPS-6

TPS-6L
TPS-10
TPS-10L
TPS-15
TPS-15L
TPS-20
TPS-20L
TPS-25
TPS-25L

TPS-30
TPS-30L
TPS-35
TPS-35L
TPS-40
TPS-40L
TPS-40V
TPS-50
TPS-50L

TPS-50V
TPS-60
TPS-60L
TPS-70
TPS-70L
TPS-70LB
—
—
—

Dimensional Data

• TELPOWER fuse line is the first to be specifically designed
to meet the unique needs of DC Power Distribution
Systems.
• The UL Recognized ratings of 170Vdc and 100,000A
interrupting rating along with the fuse’s current limiting
capability make this fuse ideal for cable protection on exist
ing DC Distribution Systems.
• A unique BLUE label is used on all TELPOWER fuses to
designate their DC capability.
• Circuit board applications available.
• Silver-plated brass ferrules.
• Glass melamine tube.
• For use with Bussmann Fused Disconnect Switch 15800.
• Spare Fuseholder: TPSFH-AS, see page 198.
• Printed circuit board variations available.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 5002
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 5009

179

Telpower® DC Power Protection Systems

Fused Disconnect Switch

Bussmann®

TP158HC

TP158HC
Fused Disconnect Switch
For use with Telpower® Fuses Type TPL-B.
Ampere Ratings: 70-250A
Voltage Rating: 80Vdc
UL Withstand Rating: 100,000A
Agency Information:
UL Recognized (investigated to UL 1801) as a
disconnect switch for the interruption of load current
by means of withdrawing the fuse pullout.
Guide QPQY2, File E97649.
Catalog Numbers:
TP158HC: Rear Access, Panel Mounting, English
TP158HC: Rear Access, Panel Mounting, Metric

General Information:
• High amp version of Bussmann 15800 series
Fused Disconnect Switch.
• Similar profile, mounting method, and backplane
configuration as 15800 Series. The TP158HC
can be installed into existing 15800 Series panels
using the space of two 15800 disconnects.
• Innovative new fuse pullout design eliminates
need for tools to replace the Telpower® type
TPL-B fuse.
• For use with the following fuses only:
Main: Telpower® TPL-B 70-250 Amperes.
Alarm: Bussmann GMT-A only.
• Alarm output with wire wrap terminal or connection to
.063” thick common alarm bus.
• Hardware included:
Load: washer, split lockwasher, and 5/16 _ 18 nut.

Easy Fuse Replacement

• Thermoplastic housing material UL rated 94V-0, 150°C.
• Spare fuseholders:
for TPL-B fuses (TPSFH-LB), see page 14;
for GMT fuses (TPSFH-T), see page 14.
• Application Note: The line connection uses a 1/4-20 bolt
(metric – M6X1) that threads into the line terminal. The line
terminal is designed with a float of ±.02 in. (± .50mm) to
allow for variation in the distance between the TP158HC
mounting flange and the line bus bar (see dimensional
data). Equipment should be designed to eliminate any relative movement between the TP158HC mounting flange
and the line bus bar.
• Application Note: The alarm circuit is not intended for
precharging of capacitive circuits. Alarm circuit current
1A maximum.

Data Sheet: 5021

180

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Telpower® DC Power Protection Systems

Fused Disconnect Switches

15100

15200

Fused Disconnect
System
For use with Telpower®
Fuses Type TPL.
Ampere Ratings: 70-800A.
Voltage Rating: 60Vdc
UL Withstand Rating: 100,000A
Agency Information:
UL Recognized, Guide QPQY2, File E97649

Ampere Ratings: 70-800A
Voltage Rating: 60Vdc
UL Withstand Rating: 100,000A
Agency Information:
UL Recognized, Guide QPQY2, File E97649

Catalog Numbers
15100-401
15100-601

Fused Disconnect
System
For use with Telpower®
Fuses Type TPL.

For Use With TPL series fuses
For Use With TPL series fuses

70-400A
300-800A

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data 15100-401

Catalog Numbers
15200-602

For Use With TPL 70 to 800A

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data 15200-602

6.75"

(171.45mm)

3"

1"

(76.2mm)

(25.4mm)

3"

4"

(76.2mm)

(101.6mm)

5.86"

(149.22mm)

8.69"

(220.66mm)

0.27" (6.75mm) Dia. Hole with 0.5" (12.7mm)
Dia. x 0.16" (3.97mm) Deep C'bore (4 Holes)
5.75"

(146.05mm)

2"

0.88"

(50.8mm)

(22.22mm)

#14 Thd.

1.88"

(47.62mm)

7.25"

(184.15mm)

3.63"

(92.07mm)

0.31" (7.93mm) #18 Tap x 0.5" (12.7mm) Deep (4 Holes)

2.75"

(69.85mm)

7.13"

(181.10mm)

6.75"

5"

(127.0mm) (171.45mm)

0.5"
11"

(12.7mm)

(279.4mm)

1.31"

(33.33mm)

12"

2.63"

(304.8mm)

(66.67mm)

5.25"

(133.35mm)

Data Sheet: 5003
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 5004

181

Telpower® DC Power Protection Systems

Bussmann®

Telpower® High Current Switch
TPHCS-Dimensional Data

mm
(in)

Ø 7.62
(0.300)
Typ. 4

▲

▲

41.02
(1.615)
▲

66.4
(2.62)
▲

22.2
(0.88)

▲

▲

▲

▲ ▲

▲

▲

▲
▲

122.43
(4.820)

▲

25.9
(1.02)

8.8
(0.34)

▲

▲

12.7
(0.50)

17.3
(0.68)

▲

▲

▲

▲

▲

100.5 REF
(3.96)
74.6
(2.94)

▲
▲

▲

Threaded Insert, 4 Places
M8x1.25 (-M Series) 5/16-18 (-E Series)
Recommended Torque 15N • m (11 Ft-lb)
▲

NOTES:
1. TPHCS250 and
TPHCS800
pullouts and bases
24.8 REF
are the same with
(0.98)
exception to the
▲
type of fuse, TPL-B,
TPL-C or TPH the
▲
pullout will carry.
2. Plastic rated UL94
16.76
V-0, 140°C RTI.
(0.660)

▲

105.2
(4.14)
139.7
(5.50)

Tin Plated
Copper
Terminals

Catalog Numbers-Switches (Pullout and Base)
TPHCS250-M
High Current Switch, Metric
TPHCS250-E
High Current Switch, English
TPHCS250-ML High Current Switch, Metric, LED
TPHCS250-EL
High Current Switch, English, LED
TPHCS250-MAV High Current Switch, Metric, Alarm
TPHCS250-EAV High Current Switch, English, Alarm
TPHCS800-M
High Current Switch, Metric
TPHCS800-E
High Current Switch, Englis
TPHCS800-ML High Current Switch, Metric, LED
TPHCS800-EL High Current Switch, English, LED
TPHCS800-MAV High Current Switch, Metric, Alarm
TPHCS800-EAV High Current Switch, English, Alarm

Series Fuse
TPL-B
TPL-B
TPL-B
TPL-B
TPL-B
TPL-B
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH

Ampere Rating
70 to 250A
70 to 250A
70 to 25 A
70 to 250A
70 to 250A
70 to 25 A
300 to 800A
300 to 800A
300 to 800A
300 to 800A
300 to 800A
300 to 800A

Catalog Numbers – Components
TPHCS250-P
Pullout only – 250 A
TPHCS800-P
Pullout only – 800 A
TPHCS-B-M
Base only, Metric
TPHCS-B-E
Base only, English
TPHCS-B-ML
Base only, Metric, LED
TPHCS-B-EL
Base only, English, LED
TPHCS-B-MAV Base only, Metric, Alarm
TPHCS-B-EAV
Base only, English, Alarm

Series Fuse Ampere Rating
TPL-B
70 to 250A
TPL-C or TPH 300 to 800A
—
800A Max.
—
800A Max.
—
800A Max.
—
800A Max.
—
800A Max.
—
800A Max.

▲

▲

▲

▲

▲

39.2 REF
(1.54)

61.47
(2.420)

▲

General Information:
• Innovative new design eliminates need for tools to
replace the Telpower® type TPL-B, TPL-C or
TPH fuse.
• Easy to install–captive fasteners allow for direct
busbar mounting (bolts not included).
• Optional new electronic alarm provides both local
and remote open-fuse indications.
—Bipolar alarm designed for both Central Office and
Radio applications.
—Local LED alarm indication for ease-of-viewing.
—Standard ⁄Ω¢∑ male quick-connect terminal for
effortless remote alarm connection (Maximum
remote alarm current: 20mA).
—Eliminates need for parallel indicating fuses.
• Fuse presence window allows for easy viewing of
installed fuse ampere rating.
• Compact design for today’s high power, high-density
cabinets.
• Available as complete switch or pullout and base
may be purchased separately.

See table for part
number format

▲

Telpower® High Current Switch
For use with Telpower® Fuses Type TPL-B, TPL-C
and TPH.
Ampere Ratings: 70 to 800A
Voltage Rating: 80Vdc
UL Withstand Rating: 100,000A
Agency Information:
UL Recognized (investigated to UL 1801) as a
disconnect switch for the interruption of load current
by means of withdrawing the fuse carrier.
UL Recognized to meet the requirements for Canadian
Standards.

▲

TPHCS

13.2
(0.52)

▲

TPHCS800-MAV (shown)

Data Sheet: 5020

182

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Telpower® DC Power Protection Systems

Bussmann®

Telpower® Fuses, 70-600 Amps, 170 Volts DC
Dimensional Data
2.66"
(67.5mm)

2.19"
(55.6mm)

1.91"
(48.4mm)

1.0"

1.16"

(25.4mm)

(29.4mm)

BUSS
.75"
(19.1mm)

TPL–BL
.33"

.19"

(8.3mm)

(4.8mm)

TPL-BA, TPL-BD, TPL-BF, TPL-BH, TPL-BK, AND TPL-BL

TPL

3.50"
(88.9mm)

2.44"

DC Power Distribution Fuses
Ampere Ratings: 70-800A
Voltage Rating: 170Vdc
Current Limiting
Interrupting Rating: 100,000A
Construction: Silver-Plated Terminals
Agency Information:
UL Recognized Guide JFHR2, File E56412
Bellcore

(61.9mm)

1.50"

1.25"

(38.1mm)

(31.8mm)

BUSS
1.00"
(25.4mm)

TPL–CZ
.41"
(10.3mm)

.25"
(6.4mm)

TPL-CN, TPL-CR, TPL-CV, AND TPL-CZ
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Ordering Information:
TPL Telpower® (170Vdc)
Catalog
Number

Ampere
Rating

Weight*

Carton
Qty.

Lbs.

Kg.

TPL-BA

70

5

.93

.42

TPL-BB

80

5

.93

.42

TPL-BC

90

5

.93

.42

TPL-BD

100

5

.93

.42

TPL-BE

125

5

.93

.42

TPL-BF

150

5

.93

.42

TPL-BG

175

5

.93

.42

TPL-BH

200

5

.93

.42

TPL-BK

225

5

.93

.42

TPL-BL

250

5

.93

.42

TPL-CN

300

1

.49

.22

TPL-CO

350

1

.49

.22

TPL-CR

400

1

.49

.22

TPL-CU

450

1

.49

.22

TPL-CV

500

1

.49

.22

TPL-CZ

600

1

.49

.22

TPL-CZH

800

1

.49

.22

•
•
•
•
•

Designed for DC power distribution systems.
Recognized branch circuit protection.
Current-limiting capability.
Complete system coordination capability.
Energy savings with low watts loss, low operating temperatures, and minimum I2t levels.
• Use with Telpower 15100, 15200, TP158HC and TPHCS
disconnect systems.
• For replacement of Bussmann’s UBO fuses a TPL-TA adaptor kit is necessary.
• Spare fuseholders:
TPSFH-LB (for TPL-B fuses)
TPSFH-LC (for TPL-C fuses)

*Weight per carton.

Data Sheet: 5005
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

183

Telpower® DC Power Protection Systems

Bussmann®

Telpower® Fuses, 1-600 Amps, 170 Volts DC
0.56"
(14.3mm)

2"
(50.8mm)

1A to 30A
0.81"

(20.6mm)

3"
(76.2mm)

35A to 60A
5.88"

(149.2mm)

1.00"

TPN

(25.4mm)

Current Limiting
DC Power Distribution Fuses
Ampere Ratings: 1-600A
Voltage Rating: 170Vdc
Interrupting Rating: 100,000A
Construction: Silver-Plated Terminals
Agency Information:
UL Recognized, Guide JFHR2, File E56412

70A to 100A
7.13"

(181.0mm)

1.50"
(38.1mm)

110A to 200A
8.63"

(219.1mm)

2.00"
(50.8mm)

225A to 400A
10.38"
(263.5mm)

Catalog Numbers
TPN-1

TPN-45

TPN-200

TPN-3

TPN-50

TPN-225

TPN-5

TPN-60

TPN-250

TPN-6

TPN-70

TPN-300

TPN-10

TPN-80

TPN-350

TPN-15

TPN-90

TPN-400

TPN-20

TPN-100

TPN-450

TPN-25

TPN-110

TPN-500

TPN-30

TPN-125

TPN-600

TPN-35

TPN-150

TPN-40

TPN-175

Carton
Qty.

450A to 600A

Recommended Class R Fuseblocks
Amps
1 to 30

35 to 60

Carton Quantity and Weight
TPN Telpower (170Vdc)
Catalog
Number

2.50"
(63.5mm)

70 to 100
Weight*
Lbs.

Kg.

110 to 200

Poles

Catalog
Number

1

R25030-1CR

2

R25030-2CR

3

R25030-3CR

1

R25060-1CR

2

R25060-2CR

3

R25060-3CR

1

R25100-1CR

2

R25100-2CR

3

R25100-3CR

1

R25200-1CR

3

R25200-3CR

1-30

10

0.45

0.204

35-60

10

1.82

0.824

225 to 400

1

R25400-1CR

70-100

5

1.85

0.838

450 to 600

1

R25600-1CR

110-200

1

1.05

0.476

225-400

1

2.38

1.078

450-600

1

3.50

1.587

*Weight per carton.

• Designed for DC power distribution systems.
• The TPN series of fuses are dimensionally similar to Class R
fuses.
• Recognized branch circuit protection.
• Current-limiting capability.

• Complete system coordination capability.
• Energy savings with low watts loss, low operating temperatures, and minimum I2t levels.
• Spare fuseholders:
TPSFH-N30 (for TPN 1-30)
TPSFH-N60 (for TPN 35-60)

Data Sheet: 5006

184

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Telpower® DC Power Protection Systems

Indicating Fuse & Holder

70 Series

15087 Fuseholder

Indicating Type Fuse
Voltage Rating: 125Vac; 300Vdc
Agency Information:
UL Recognized, Guide JDYX2, File E19180
Bellcore

For 70 Series Fuses
Ampere Ratings: 12A
Voltage Rating: 300Vdc
Agency Information:
UL Recognized, Guide IZLT2, File E14853
Construction:
Body: Thermoplastic, UL 94VO flammability rating
Terminals: Copper alloy, tin plating
Screws: 3-24 ≈ ‹Ω•∑ steel, zinc plated

70 Series Telpower (125Vac, 300Vdc)
Catalog
Number

Ampere
Rating

70P-⁄Ω¡º A*
70R-⁄fiΩ¡ººA*
70E-⁄°Ω¡ºº A*
70X-¤Ω¡º A
70F-⁄Ω¢ A*
70K-⁄Ω¢ A*
70G-⁄Ω™ A*
70H-‹Ω¢ A*
70I-1A
70A-1-⁄Ω£ A*
70B-2A*
70C-3A*
70J-3⁄Ω™ A
70D-5A*
70L-6A
70M-8A
70N-10A
GKB-10A
72A
Plastic Case
72B
Blister Pack

⁄Ω¡º
⁄fiΩ¡ºº
⁄°Ω¡ºº
¤Ω¡º
⁄Ω¢
⁄Ω¢
⁄Ω™
‹Ω¢
1
1⁄Ω£
2
3
3⁄Ω™
5
6
8
10
10

Voltage Rating
AC
DC

Color
Code

Lucent
Comcode
Ref. No.

Code/
List No.

Gray/Wh
Red/Wh
Yellow
Black
Violet
Violet/Wh
Red
Brown
Pink
White
Orange
Blue
Black/Wh
Grn/Blk
Grn/Wh
Brown/Wh
Violet/Yel
Violet/Yel

100203413
101384550
100203363
—
100203371
100203405
100203389
100203397
—
100203322
100203330
100203348
—
100203355
—
—
—
—

KS23751-L10
KS23751-L11
KS23751-L5
—
KS23751-L6
KS23751-L9
KS23751-L7
KS23751-L8
—
KS23751-L1
KS23751-L2
KS23751-L3
—
KS23751-L4
—
—
—
—

125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V

300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V
300V

Dummy

—

—

—

100203421

—

Dummy

—

—

—

103757977

—

*Product designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1,
December 1988.

• Panel mount fuseholder for 70 Type fuses supplied with
two screws.
• Remote alarm capability.
Optional Color Code Eyelets (order separately)
Catalog
Symbol
1A1706-01
1A1706-02
1A1706-03
1A1706-04
1A1706-05
1A1706-06
1A1706-07
1A1706-08
1A1706-09

Amp
Rating
Ref.
⁄°Ω¡ºº
¤Ω¡º
⁄Ω¢
⁄Ω¢
⁄Ω™
‹Ω¢
1
1⁄Ω£
2

Color
Code
Yellow
Black
Violet
Violet/White
Red
Brown
Pink
White
Orange

Catalog
Symbol

Amp
Rating
Ref.

1A1706-10
1A1706-11
1A1706-12
1A1706-13
1A1706-14
1A1706-15
1A1706-16
1A1706-17
—

3
5
6
8
10
⁄Ω¡º
3⁄Ω™
⁄fiΩ¡ºº
—

Color
Code
Blue
Green/Black
Green/White
Brown/White
Violet/Yellow
Gray/White
Black/White
Red/White
—

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 5007
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 5007

185

Telpower® DC Power Protection Systems

Bussmann®

Indicating Fuses & Holders

GMT - Dummy

GMT - A (Alarm)

GMT

HLS, HLT, PCT

Fast Acting Fuses
Voltage Rating: 60Vdc; 125Vac
Interrupting Rating: 450A, 60Vdc;
300A, 125Vac
Agency Information:
UL Recognized, Guide JFHR2, File E56412
Materials:
Body: Thermoplastic, UL 94VO flammability rating
Terminals: Tin-plated Beryllium copper
Carton Qty. and Weight: 100 Fuses per carton;
0.33 lbs. (150g)
Fuseholders: Catalog No. HLT, HLS, and PCT
Spare Fuseholder: TPSFH-T

Fuseholders for GMT Type Indicating Fuses
Voltage Rating: 60Vdc; 125Vac
Agency Information:
UL Recognized, Guide IZLT2, File E14853, 15A (60Vdc)
Materials:
Body: Thermoplastic, UL 94VO flammability rating
Terminals: Tin-plated copper

Catalog Numbers
Catalog
Symbol
GMT-⁄°Ω¡ººA
GMT-⁄Ω¢A
GMT-‹Ω•A
GMT-⁄Ω™A
GMT-flfiΩ¡ººA
GMT-‹Ω¢A
GMT-1A
GMT-1⁄Ω£A
GMT-1⁄Ω™A
GMT-2A

Color
Code
Yellow
Violet
White/Gray
Red
Black
Brown
Gray
White
White/Yellow
Orange

Catalog
Symbol
GMT-3A
GMT-3⁄Ω™A
GMT-4A
GMT-5A
GMT-7⁄Ω™A
GMT-10A
GMT-12A
GMT-15A
GMT-Dummy
GMT-X

Color
Code
Blue
White/Blue
White/Brown
Green
Black/White
Red/White
Yellow/Green
Red/Blue
Gray Body
Clear Cover

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
Some GMT sizes may be sold in bulk pack only.

GMT-A

•The GMT-A is designed specifically for use in the Telpower®
series 15800 Fused Disconnect Switch (page 177).
• The GMT-A has the same ratings and agency approvals
as the standard GMT fuses as shown above.
Catalog Symbol
GMT-A

Data Sheet: 5008

186

Color Code
Yellow

Multiple Fuseholders with bus bars
Ordering Information— Catalog No.

Body Style HLT
HLS (No flanges)

Termination Location

No. of Poles 01 thru 25
(Min. of 2 poles required for bus bars)

L

R

(Left only)

(Right only)

B
Type of bus bars used***
B1*, B2, B3,
B4, B5, SL** (Short Leads .135")
ML** (Medium Leads .250")

(Both ends)

** Not available with bus bars

Bus Bar Position

B1
(Angle Bar Only)*

B4
(Angle & “L” Bars)

B2
(“L” Bar Only)

B3
(“U” Bar Only)

P1†
(Inside—
Both Sides)

P2
(Outside—
Both Sides)

P3
(Outside—
Right Only)

P4
(Outside—
Left Only)

B5
(“L” & “U” Bars)

*Angle Bar mounts on common or center terminals only.
** SL Version is not available with bus bars.
†Minimum of 4 Poles Required.
***.38 max. leads if not specified.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 5010
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Telecommunications
Protection Systems
Telpower® DC Power Protection

Bussmann®

Telpower® Specialty Fuses

Dimensional Data

Dimensional Data
A
4.093"

2.685"
(68.20mm)

.280"
(7.11mm)

81 Type

7 Type

Description: Cylindrical, fast acting, non-indicating high
current companion to the 80 Type. UL Recognized, Guide
JDYX2, File E19180.

Description: Fiber tube, threaded ends. Typically used
on wall type main distribution frames and central battery
substations.

Catalog Data

Catalog Data

Catalog
Symbol
81B-7⁄Ω™

Ampere
Rating
7.5

Voltage Rating
ac
dc

Color
Code

Lucent Comcode
Ref. No.

Code/
List No.

Catalog
Symbol

Ampere
Rating

Lucent Comcode
Ref. No.

Dimension
A Length

250V

65V

Gray

103828141

KS23824-L12

7 Type

81A-10

10

250V

65V

Yellow

103752176

KS23824-L11

7A-7

7

100863737

4.562

81C-12

12

250V

65V

Lt Blue

104391842

KS23824-L13

7T-7

7

100202753

4.828

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data
1.406"
.938"
A

Dimensional Data
A .375"

4.625"
4.062"

24 and WER Type
Description: Flat, nonindicating visible link element mounted
on 1 inch centers using either No. 6 or No. 10 screws.
Catalog Data
Catalog
Ampere
Symbol
Rating
WER-⁄Ω¢
⁄Ω¢
24E-⁄Ω™*
⁄Ω™
24D-‹Ω¢*
‹Ω¢
WER-1
1
24G-1⁄Ω£*
1⁄Ω£
24C-2*
2
24B-3*
3
WER-3⁄Ω™
3⁄Ω™
24B-4*
4
24F-5*
5
WER-8
8
WER-10
10
64A-Dummy
—

dc
Volt.
32V
60V
60V
32V
60V
60V
60V
32V
60V
60V
32V
32V
—

Color
Code
—
Red
Black
—
White
Orange
Blue
—
Yellow
Green
—
—
—

Lucent Comcode
Ref. No.
—
100202894
100202886
—
100202910
100202878
100202852
—
100202860
100202902
—
—
100203280

Dimension
A Length
—
.200
.150
—
.200
.200
.150
—
.150
.150
—
—
—

11 Type
Description: Fiber tube, threaded ends, identical to 7 Type
except for vent slots in fiber tube.
Catalog Data
Catalog
Symbol

Ampere
Rating

Lucent Comcode
Ref. No.

Dimension
A Length

100863745

—

11 Type
11C-7

7

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

*Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

For
For complete
complete specification
specification data,
data, call
call Bussmann
Bussmann Information
Information Fax
Fax ~~ 636.527.1450
636.527.1450

187

Bussmann®

Telecommunications Protection

Telpower® Specialty Fuses
Dimensional Data

Dimensional Data
.620"
(15.75mm)

— —A

BUSS

1.25"

.325"
(8.26mm)

.281"

(31.75mm)

(7.14mm)

74 Type

.190"

Description: .281∑ ≈ 1.25∑ cylindrical fuse, fast acting.
Designed to comply with Lucent specification KS23753.
High current companion to 70 Type Fuse.
Catalog Data

(4.83mm)

.800"

75 Type

Description: Cylindrical with leads, designed to provide
protection against currents resulting from the application of
foreign voltages. Application for data sets and telephones.

Catalog
Symbol

Ampere
Rating

Voltage Rating
DC

Lucent Comcode
Ref. No.

Code/
List No.

74A-1⁄Ω¢

1⁄Ω¢

60V

102630290

KS23753-L1

Catalog Data
Catalog
Symbol

74G-2

2

60V

103064952

KS23753-L7

74B-3

3

60V

102630308

KS23753-L2

74H-4

4

60V

103264669

KS23753-L8

74C-5

5

60V

102630316

KS23753-L3

7⁄Ω™

60V

103228425

KS23753-L9

60V

102630324

KS23753-L4

74J-7⁄Ω™
74D-10

10

74E-15

15

60V

102630332

KS23753-L5

74F-20

20

60V

102630340

KS23753-L6

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

(20.32mm)

Ampere
Rating

Voltage Rating
AC
DC

Lucent Comcode
Ref. No.

Code/
List No.
KS23825-L3

75C

.007

135V

440V

103260816

75F

.063

135V

220V

104172861

KS23825-L6

75B

.115

135V

220V

102732112

KS23825-L2

75D

.129

135V

220V

104013180

KS23825-L4

75A

.200

135V

220V

102660008

KS23825-L1

75E

.230

135V

220V

104015292

KS23825-L5

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensional Data
.445"

.830"

(11.30mm)

(21.08mm)

Dimensional Data

BUSS

— —A

2.685"
(68.20mm)

.280"
(7.11mm)

80 Type

.320"
(8.13mm)

1.125"
(28.58mm)

76 Type
Description: Cylindrical with leads, designed to provide
protection against currents resulting from the application of
foreign voltages. Application for data sets and telephones.
Catalog Data
Catalog
Symbol

Ampere
Rating

Voltage Rating
AC
DC

76D

.012

135V

76B

.191

76A
76C

Catalog Data
Catalog
Symbol

Voltage Rating
AC
DC

Color
Code

.50

250V

—

1.33

250V

—

2

250V

80C-3

3

80D-5

5

Lucent Comcode
Ref. No.

Code/
List No.

440V

103798245

KS23825-L10

80M-1⁄Ω£

135V

440V

102965688

KS23825-L8

80B-2

.231

135V

440V

102810181

KS23825-L7

.412

135V

440V

103656625

KS23825-L9

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

188

Description: A fuse designed for high reliability applications
where high ambient temperatures, low circuit voltages, low
power dissipation and low contact resistance are prime considerations. The 80 Type is a visual indicating fuse with remote
electrical alarm capability. UL Recognized, Guide JDYX2,
File E19180.

80G-⁄Ω™

Ampere
Rating

Lucent Comcode
Ref. No.

Code/
List No.

Red

103839916

KS23824-L6

White

408078657

KS23824-L8

—

Orange

103752150

KS23824-L2

250V

—

Blue

103752168

KS23824-L3

250V

—

Green

103800637

KS23824-L4

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Pg 189
Do not Print

Bussmann®

British, European, & Canadian Standard Industrial Fuses

CSA Type P and Type D Fuses

CDS, CDN & PON

Dimensional Data

Voltage Ratings: 250V (CDN & PON) & 600V (CDS)
Interrupting Rating: 10kA minimum
Agency Information: CSA Certified to C22.2 No. 59.1

A

B

Time-Delay CSA Type “D”
Volts

250V

600V

Cat. No.

CDN

Amp Ratings

Ctn. Qty.

Below 10A use FRN-R
10, 12, 15, 20, 25, 30,
35, 40, 45, 50, 60

10

70, 80, 90, 100

5

110, 125, 150, 175, 200,
225, 250, 300, 350, 400,
450, 500, 600

1

Below 10A use FRS-R
10, 12, 15, 20, 25, 30,
35, 40, 45, 50, 60

10

70, 80, 90, 100

5

110, 125, 150, 175, 200,
225, 250, 300, 350, 400,
450, 500, 600

1

Cat. No.

Amp Ratings

Ctn. Qty.

PON

15, 20, 25, 30, 35,
40, 45, 50, 60

10

CDS

Ferrule Design 1 through 60A

250V

A
Catalog
Number
and Volts

CDN
PON
250 Vac

Amps

Overall
Inches
(mm)

B

F

B
Maximum
Diameter
Inches
(mm)

E

Knife Blade 70 through 600A
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

One-Time CSA Type “P”
Volts

A
D

C

C
Minimum
Blade Length
Inches
(mm)

D
Minimum
Barrel Length
Inches
(mm)

E
Blade
Thickness
Inches
(mm)

F
Blade
Width
Inches
(mm)

1-30

2.0

(50.8)

.56

(14.3)

—

—

—

—

—

—

—

35-60

3.0

(76.2)

.81

(20.6)

—

—

—

—

—

—

—

—
—

70-100

5.88

(149.4)

—

—

1.0

(25.4)

—

—

.13

(3.2)

.75

(19.1)

110-200

7.3

(185.4)

—

—

1.38

(34.9)

4.13

(104.8)

.19

(4.8)

1.13

(28.6)

225-400

8.63

(219.2)

—

—

1.88

(47.6)

4.63

(117.5)

.25

(6.4)

1.63

(41.3)

450-600

10.38

(263.7)

—

—

2.25

(57.2)

5.19

(131.8)

.25

(6.4)

2

(50.8)

1-30

5.0

(127.0)

.81

(20.6)

—

—

—

—

—

—

—

—

35-60

5.5

(139.7)

1.06

(27.0)

—

—

—

—

—

—

—

—

CDS

70-100

7.88

(200.2)

—

—

1.0

(25.4)

—

—

.13

(3.2)

.75

(19.1)

600V

110-200

9.63

(244.6)

—

—

1.38

(34.9)

6.13

(115.6)

.19

(4.8)

1.13

(28.6)

225-400

11.63

(295.4)

—

—

1.88

(47.6)

7.13

(118.1)

.25

(6.4)

1.63

(41.3)

450-600

13.38

(339.9)

—

—

2.25

(57.2)

8.19

(208.0)

.25

(6.4)

2

(50.8)

Data Sheet: 4126

190

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

British, European, & Canadian Standard Industrial Fuses

HRC Form II Class C Fuses
Dimensional Data
0.22"

0.81"

0.22"

(20.64mm)

(5.56mm) (5.56mm)

0.06"

2.0"

(1.59mm)

0.34"

(50.8mm)

2.80"

0.94"

(8.73mm)

(23.81mm)

(71.04mm)

3.31"
(84.14mm)

CGL 1-30
0.22"

0.81"

0.22"

(20.64mm)

(5.56mm) (5.56mm)

0.06"

2.0"
(50.8mm)

(1.59mm)

0.50"

2.80"

1.06"

(12.7mm)

(71.04mm)

(26.92mm)

3.5"

CGL

(88.9mm)

Tron® HRC Form II Class C Fuses
Ampere Ratings: 2 to 600A.
Voltage Rating: 600Vac, 250Vdc (1-30A)
Interrupting Rating: 200,000A (40,000A dc)
Current Limiting
Agency Information: CSA Certified, C22.2 No. 106

CGL 35-60

0.343"

0.343"

(8.71mm)

(8.71mm)

2.39"
(60.72mm)

3.64"

1.34"
(34.04mm)

0.09"
(2.29mm)

0.75"

1.375"

(19.05mm)

(34.93mm)

(92.47mm)

4.31"

• Tron® HRCII-C fuses are designed to withstand inrush currents on typical motor start-ups while offering high current
limitation in the short-circuit region.
• The Tron® HRCII-C fuses can be sized close to the motor
nameplate rating.
• Closer protection is offered for many motor sizes with the
availability of these additional fuse ratings.
• Tron® HRCII-C fuses have a high degree of current limitation
greatly reducing the magnetic forces and thermal stresses
produced in today’s high capacity systems.

(109.54mm)

CGL 70-100

0.343"
(8.71mm)

0.343
(8.71mm)

0.125"

3.00"

(3.18mm)

0.75"

(76.2mm)

(19.05mm)

4.30"
(109.22mm)

1.50"
(38.1mm)

5.31"
(134.87mm)

CGL 110-200
0.19"
(4.76mm)

Catalog Numbers (Ampere ratings)

1.0"

0.38"

(25.4mm)

(9.53mm)

CGL-1

CGL-40

CGL-175

CGL-2

CGL-45

CGL-200

CGL-3

CGL-50

CGL-225

CGL-4

CGL-60

CGL-250

CGL-6

CGL-70

CGL-300

CGL-10

CGL-80

CGL-350

CGL-15

CGL-90

CGL-400

CGL-20

CGL-100

CGL-450

CGL-25

CGL-110

CGL-500

CGL-30

CGL-125

CGL-600

CGL-35

CGL-150

—

1.0"
(25.4mm)

3.0"

2.38"

(76.2mm)

(60.33mm)

5.25"
(133.35mm)

8.19"
(207.96mm)

CGL 225-400

1.0"

0.41"

(25.4mm)

(10.32mm)

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

1.0"
(25.4mm)

.60"
3.0"
(76.2mm)

5.25"
(133.35mm)

8.19"

(15.24mm)

0.375"
(9.53mm)

3.00"
(76.2mm)

(207.96mm)

CGL 450-600

Data Sheet: 4125
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

191

British, European, & Canadian Standard Industrial Fuses

Bussmann®

HRCI Industrial Ceramic Body Fuses
CIF21

Dimensional Data

HRCI-CA Bolt-On Mounting
Ampere Ratings: 1-30A
Voltage Rating: 600Vac; 250Vdc
Interrupting Rating: 200,000A RMS
Symmetrical
Agency Information: CSA C22.2
No. 106-M92

A
C

D

• Provides both overload and shortcircuit protection to HRCI requirements.
• Offset blades for bolt-on mounting.
• CIF21 fuse fits the Bussmann-Camaster
Fuseholder.

E

H

F

G
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensions in Inches and (mm)
Type
HRCI-CA

Catalog
Symbol

Current
Ratings

Overall

Tags

A

E

F

G

Mounting
H

C

Body
D

(AMP) CIF21

1, 3, 10, 15,
20, 25, 30

2.15
(54.50)

.44
(11.10)

.03
(0.81)

1.75
(44.50)

.19
(4.70)

1.44
(35.50)

.54
(13.80)

Data Sheet: 4127

Dimensional Data
A
C

D

E

N

F

• Industrial miniature fuse with offset blades for clip-in
mounting.
• Ground ceramic body with plated endcaps.
• Provides both short-circuit and overload protection.
• CIF06 fits the 30A SafeLOC fuseholder.
EK fits the 60A SafeLOC fuseholder.

CIF06 & EK
HRCI-CB Clip-In Mounting
Ampere Ratings: CIF06: 1-30A, EK: 35-60A
Voltage Rating: 600Vac; 250Vdc
Interrupting Rating: 200,000A RMS Symmetrical
Agency Information: CSA C22.2 No. 106-M92

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Dimensions in Inches and (mm)

Catalog
Symbol

Current
Ratings

A

E

F

N

C

D

(AMP) CIF06

1, 10, 15,
20, 25, 30

2.38
(60.40)

.50
(12.70)

.03
(0.81)

.14
(3.50)

1.44
(35.50)

.54
(13.80)

EK (AMP)

30, 35, 40,
50, 60

2.65
(67.30)

.58
(14.80)

.05
(1.22)

.14
(3.50)

1.44
(36.30)

.8
(21.40)

Type
HRCI-CB

Data Sheet: 4128

192

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

British, European, & Canadian Standard Industrial Fuses

HRCI-J Fast Acting Fuses
Dimensional Data
A
B

B

C

1CJ to 60CJ
E

A
K

J
C

F
H

D
B

CJ

G

70CJ to 600CJ

HRCI-J Fast Acting Fuses
Voltage Rating: 600Vac or less, 250Vdc
Construction: Ceramic Body Fuse
Interrupting Rating: 200,000A I.R.
Agency Information: CSA C22.2 No. 106 M92;
Designed to BS88:2, IEC 60269-2

Current
Ratings
(Amps)

Catalog
Number

1
3
6
10
15
20
25
30

1CJ
3CJ
6CJ
10CJ
15CJ
20CJ
25CJ
30CJ

35
40
45
50
60

35CJ
40CJ
45CJ
50CJ
60CJ

70
80
90
100

70CJ
80CJ
90CJ
100CJ

110
125
150
175
200

110CJ
125CJ
150CJ
175CJ
200CJ

225
250
300
350
400
450
500
600

225CJ
250CJ
300CJ
350CJ
400CJ
450CJ
500CJ
600CJ

• Industrial duty fuses with ceramic bodies.
• The excellent current limiting characteristics of fast-acting
HRCI-J fuses limits damage to equipment and installations
by the thermal and magnetic energy associated with a
large short-circuit fault current.
• Overload characteristics limit cable damage due to low
overload currents.

Dimensions in Inches and (mm)
A

B

C

D

E

F

G

H

J

K

2.25
(57)

.5
(12.7)

.81
(20.6)

—

—

—

—

—

—

—

2.38
(60)

.63
(16)

1.06
(27)

—

—

—

—

—

—

—

4.63
(117)

3.63
(92)

1.13
(28)

.75
(19)

.13
(3.2)

1
(25.4)

.5
(12.7)

.28
(7.1)

.38
(9.5)

2.63
(67)

5.75
(146)

4.38
(111)

1.63
(41)

1.13
(28.6)

.19
(4.8)

1.38
(35)

.69
(17.5)

.28
(7.1)

.38
(9.5)

3
(76)

7.13
(181)

5.25
(133)

2.13
(54)

1.63
(41)

.25
(6.3)

1.88
(47.6)

.94
(24)

.41
(10.3)

.53
(13.5)

3.38
(86)

8
(203)

6
(152)

2.63
(66)

2
(51)

.38
(9.5)

2.13
(54)

1
(25.4)

.53
(13.5)

.69
(17.5)

3.75
(96)

Data Sheet: 4129
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

193

Bussmann®

British, European, & Canadian Standard Industrial Fuses

HRCI-Misc. Type K Fuses

Dimensional Data

CIH, CIK & CIL
HRI Ceramic Body Fuses
Ampere Ratings: 30, 60 & 100A
Voltage Rating: 600V
Interrupting Rating: 200,000A at 600V
Agency Information: CSA C22.2 No. 106 M92
• Offset blades for bolt down mounting.
• Provides both overload and short-circuit protection.

K

F
A

D

J
E

G

B
L
C

H

G

(The CIL14 has a rejection hole, not a slot as shown above.)
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Ratings, Categories and Dimensions
Dimensions in Inches and (mm)

Current
Ratings
(Amps)

Catalog
Number

1
3
6
10
15
20
25
30
35
40
50
60

1CIH07
3CIH07
6CIH07
10CIH07
15CIH07
20CIH07
25CIH07
30CIH07
35CIK07
40CIK07
50CIK07
60CIK07

80
90
100

80CIL14
90CIL14
100CIL14

A

B

C

D

E

F

G

H

J

K

L

Max.

Max.

Max.

Nom.

Nom.

Nom.

Nom.

Nom.

Max.

Nom.

Max.

2.25
(57)

.94
(24)

3.38
(86)

.38
(9.2)

.04
(1.0)

2.88
(73)

.21
(5.2)

.31
(8)

1
(25.4)

.10
(2.6)

2.38
(60)

2.28
(58)

1.06
(27)

3.56
(91)

.5
(12.7)

.05
(1.2)

2.88
(73)

.21
(5.2)

.41
(10.5)

1.09
(28)

.13
(3.2)

2.38
(61)

2.75
(70)

1.44
(37)

4.38
(111)

.75
(19)

.09
(2.5)

3.69
(94)

.34
(8.7)

.41
(10.5)

1.5
(38.5)

—
—

2.91
(74)

Recommended Fuseholders
Fuse

Fuseholder

1-30A

CM30CF

35-60A

CM60CF

80-100A

CM100CF

Data Sheet: 4130

194

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

British, European, & Canadian Standard Industrial Fuses

HRC Form II Current Limiting Fuses
Dimensional Data
F
G

J

A

E

D

H07C (Offset Blades)

B
H
C

F

J
E

A
G

K07C/K07CR/
L14C/M14C
(Offset Blades)

D
B
H

HRC Form II Current Limiting Fuses

C

Voltage Rating: 600Vac or less, 250Vdc
Construction: Ceramic Body
Interrupting Rating: 200,000A RMS Symmetrical
Agency Information:
CSA C22.2 No.106M1992; BS88:2, IEC269:2

C
H

G

B

A

E

F

Applications
• HRC FORM II fuses are often used to protect motor control
circuits, together with contactors and overload protection
relays.
• Type 2 coordination - per IEC 947-4.

K

2
4
6
10
15
20
25
30
40
50
60
80
100
80
100
125
150
200
80
100
125
150
200
250
300
350
400
250
300
350
400
450
500
600

Catalog
Number
2H07C
4H07C
6H07C
10H07C
15H07C
20H07C
25H07C
30H07C
40K07C
50K07C
60K07C
80K07CR
100K07CR
80L14C
100L14C
125M14C
150M14C
200M14C
80L09C
100L09C
125M09C
150M09C
200M09C
250P09C
300P09C
350P09C
400P09C
250P11C
300P11C
350P11C
400P11C
450R11C
500R11C
600R11C

K

F

B

A
G

P11C/R11C
(Center Blades)

D

H

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Current
Ratings
(Amps)

L09C/M09C/P09C
(Center Blades)

D

E

C

Dimensions in Inches and (mm)

CSA
Category

A

B

C

D

E

F

G

H

J

K

1.38
(35)

.56
(14)

3.38
(85)

.38
(9)

.06
(1.2)

2.88
(73)

.22
(5.6)

.31
(8)

.56
(14)

—
—

HRCII-C

2.19
(56)

.88
(22)

3.44
(87)

.5
(13)

.06
(1.2)

2.88
(73)

.22
(5.6)

.31
(8)

.88
(22)

—
—

HRCII-C

2.19
(56)
2.38
(60)

.88
(22)
.88
(21.4)

3.75
(95)
4.38
(111)

.5
(13)
.56
(14.3)

.06
(1.2)
.13
(3.2)

2.88
(73)
3.69
(94)

.22
(5.6)
.34
(8.7)

.31
(8)
.44
(11)

.88
(22)
1
(25.4)

—
—
—
—

2.56
(65)

1.5
(38)

4.38
(111)

.75
(19)

.09
(2.4)

3.69
(94)

.34
(8.7)

.44
(11)

—
—

—
—

HRCII-MISC

2.38
(60)

.88
(21.4)

5
(127)

.56
(14)

.13
(3.2)

4.38
(111)

.34
(8.7)

.44
(11)

—
—

—
—

HRCII-MISC

2.56
(65)

1.5
(38)

5.38
(136)

.75
(19)

.13
(3.2)

4.38
(111)

.34
(8.7)

.56
(14)

—
—

—
—

HRCII-C

3.06
(178)

2.31
(59)

5.38
(136)

1
(25.4)

.19
(4.8)

4.38
(111)

.34
(8.7)

.5
(13)

—
—

—
—

HRCII-MISC

3.06
(178)

2.31
(59)

8.25
(210)

1
(25.4)

.19
(5)

5.25
(133)

.41
(10)

.63
(16)

—
—

1
25

HRCII-C

3.19
(81)

2.88
(73)

8.25
(210)

1
(25.4)

.25
(6.3)

5.25
(133)

.41
(10)

.63
(16)

—
—

1
25

HRCII-C

HRCII-MISC
HRCII-C

Data Sheet: 4131
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

195

British, European, & Canadian Standard Industrial Fuses

Bussmann®

BS88 British Standard Low Voltage Fuses

SSD, NSD, ESD

STD, NITD, AAO, BAO, OSD, CEO, DEO

Offset Blades
Meets the requirements of BS88 Part 1 and IEC269-1.
The NSD and ESD fuses comply with general purpose gG
characteristics.

Offset Bolted Blades
Meets the requirements of BS88 Part 1 and IEC269-1.
The NITD to DEO types comply with general purpose gG
characteristics. The STD type are used in 240V street lighting
cut-outs.

Catalog
No.

Ampere Ratings

SSD

2, 4, 6, 10, 16, 20, 25, 32

NSD

2, 4, 6, 10, 16, 20, 25, 32
20M25*, 20M32*
20M36*, 32M36*, 32M40*,
32M50*, 32M63*

Maximum
Voltage Rating
ac
dc

BS88
Ref.

Data
Sheet
4105

240

—

E1

550

—

F1

Catalog
No.

Ampere Ratings

Maximum
Voltage Rating
ac
dc

BS88
Ref.

Data
Sheet

STD

2, 4, 6, 10, 16, 20, 25, 32

240

—

—

4123

NITD

2, 4, 6, 10, 16, 20
25, 32
20M25*, 20M32*
32M40*, 32M50*, 32M63*

550
550
550
415

—
—
—
—

A1
—
A1
—

4106

AAO

2, 4, 6, 10, 16, 20, 25, 32
32M40*, 32M50*, 32M63*

550
550

—
—

A2
A2

4109

BAO

40, 50, 63
63M80*, 63M100*

550
550

—
—

A3
A3

4112

Recommended Fuseholders

OSD

550
415

—
—

—
—

4107

NSD
ESD

80, 100
100M125*, 100M160*

CEO

32, 40, 50, 63, 80, 100
100M125*, 100M160*
100M200*

550
415
415

—
—
—

A4
A4
A4

4115

125, 160, 200
200M250*, 200M315*

415
415

—
—

—
—

4117

ESD

2, 4, 6, 10, 16, 25, 32
40, 50, 63
63M80, 63M100

415
415

—
—

—
—

550
415
415

250
250
—

F2
F2
—

4100

4101

*“M” indicates motor starter ratings.

32NNSF
63ENSF

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

DEO

*“M” indicates motor starter ratings.

Recommended Fuseblock & Holders
NITD
AAO
BAO

CM32FC
CM32F
CM63F

OSD
CEO

CM100F
BH-0111

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

196

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

British, European, & Canadian Standard Industrial Fuses

BS88 British Standard Low Voltage Fuses

AC, AD, BC, BD, CD, DD, ED, EFS

EF, FF, FG, GF, GG, GH

Center Bolted Blades, Two Hole Mount

Center Bolted Blades, Four Hole Mount

Meets the requirements of BS88 Parts 1 and 2 and IEC269-1.

Meets the requirements of BS88 Parts 1 and 2 and IEC269-1.

Complies with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with
four hole mount.

Complies with general purpose gG characteristics and available up to 400A with two hole mount and up to 1250A with
four hole mount.

Catalog
No.

Ampere Ratings

Maximum
Voltage Rating
ac
dc

2, 4, 6, 10, 16, 20, 25, 32

550

250

—

4110

2, 4, 6, 10, 16, 20, 25, 32

550

250

—

4111

550
550

250
—

BD

40, 50, 63

550

CD

80, 100
100M125*, 100M160*
100M200*

550
415
415

125, 160, 200
200M250*, 200M315*

DD
ED

EFS

355, 400
400M500*

415
550

FF

450, 500, 560, 630

FG

450, 500, 560, 630

Catalog
No.

AD

40, 50, 63
63M80*, 63M100*

EF

Data
Sheet

AC

BC

Ampere Ratings

Maximum
Voltage Rating
ac
dc

BS88
Ref.

—

4113

250

—

4114

—
—
—

B1
B1
B1

4116

415
415

—
—

B2
B2

4118

250
315
315M400*
355, 400
400M500*

415
415
415
415
550

—
—
—
—
—

B3
B3
B3
B4
B4

4119

125, 160, 200, 250
315

415
415

—
—

—
—

4121

BS88
Ref.

Data
Sheet

—
—

C1
C1

4120

550

400

C2

4102

550

400

—

4122

GF

710, 800

550

250

C3

4103

GG

710, 800
1000, 1250

550
550

250
—

—
—

4104

GH

710, 800
1000, 1250

550
550

250
—

D1
D1

4108

*“M” indicates motor starter ratings.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

*“M” indicates motor starter ratings.

Recommended Fuseblock/Holder
AC

BH-0111 Modular Fuseblock

AD

200DF Fuseholder

BC

BH-0111 Modular Fuseblock

BD

200DF Fuseholder

CD

200DF Fuseholder

DD

200DF Fuseholder

ED

BH-1131 Modular Fuseblock

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

197

Bussmann®

British, European, & Canadian Standard Industrial Fuses

DIN Style Type D and Neozed Low Voltage Fuses

Type D Fuse

Neozed Fuse

Ampere Ratings: 2 to 100A.
Voltage Ratings: 500Vac
Interrupting Rating: 100kA
Agency Information:
“D” type fuses complying with DIN 49360 Part 2 and DIN
49515, operating class gL

Also suitable for use on 250Vdc systems
Ampere Ratings: 2 to 63A
Voltage Rating: 400Vac
Interrupting Rating: 100kA

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.
Catalog
Number
2D16
4D16
6D16
10D16
16D16
20D16
25D16
2D27
4D27
6D27
10D27
16D27
20D27
25D27
35D33
50D33
63D33
80D125
100D125

Dimension
“D”
6
6
6
7
10
12
14
6
6
6
8
10
12
14
16
18
20
5
7

Ampere
Rating
2
4
6
10
16
20
25
2
4
6
10
16
20
25
35
50
63
80
100

Color
Code
Pink
Brown
Green
Red
Grey
Blue
Yellow
Pink
Brown
Green
Red
Grey
Blue
Yellow
Black
White
Copper
Silver
Red

Figure
Number

1

Data Sheet: 4124

198

Figure 2

Figure 3

Dimension
D (mm)

Ampere
Rating

Color
Code

2NZ01

11

2

4NZ01

11

4

Brown

6NZ01

11

6

Green

Pink

10NZ01

11

10

Red

16NZ01

11

16

Grey

20NZ02

15

20

Blue

25NZ02

15

25

Yellow

35NZ02

15

35

Black

50NZ02

15

50

White

63NZ02

15

63

Copper

D
2

36

3

4

Additional Fuselinks: Quick acting fuselinks in body sized D16, D27, D33 and D125 rated
2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V. Gauge rings and
keys can also be supplied.

Figure 1

Catalog
Number

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Figure 4

Data Sheet: 4124
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

British, European, & Canadian Standard Industrial Fuses

Bussmann®

HRC Fuseholders

HRC Fuseholders
Ampere Ratings: 30, 60 and 100A
Agency Information: CSA C22.2 No. 39; IEC 269 AND
BS88
• Unique Cam-Action for ease of removal from the Fuse
Bases allowing significantly improved contact pressure
between Fuse Carrier and Fuse Base contacts, with a
corresponding enhanced electrical performance level.
• A range of Lockable Safety Carriers for the
Fuseholder (Cat ref: LSC), are available.

HRC Fuseholders
For use with HRCI-CB fuses. Suitable for bolted panel
mounting or DIN rail mounting.
Ampere Ratings: 30 and 60A
Ratings
For use with HRCI-CB Fuses

Rating

Details

Fuse
Accommodated

30A

For
HRCI-CA
Applications

CM20CF

—C1F21

30A
60A
100A

For
HRCII
Applications

CM30CF
CM60CF
CM100CF

—H07C
—K07C
—K07CR

Catalog
Number

Fuseholder
Accommodated

Accessories for
Rating

Details

30A
30A
60/100A

Back Stud

All

Units

20BS
32BS
60/100BS

For CM20CF
For CM30CF
For CM60/100CF

Ganging
Link Kit

GLP

For 3 Pole

All

660V Neon
Indicator

NI

30A
30A

Security
Carrier

20LSC
30LSC

—
For CM20CF
For CM30CF

Fuse
Accommodated

Connection

30A

Front
Back
Front-Back

C30F
C30BS
C30FBS

CIF06

60A

Front
Back
Front-Back

C60F
C60BS
C60FBS

EK-Amp

Ratings
Catalog
Number

Catalog
Number

Rating

Features
• Designed to accommodate the compact range of offset
blade fuse to CSA C22.2 No. 106, HRCI-CB.
• Carrier provides a positive, stress free fitting of fuse and
locks the fuse in position ensuring safe insertion and withdrawal from the base.
• Base Contacts are fully shrouded to help protect against
electric shock.
• Shrouds utilize simple slide/snap action allowing access to
the contact terminal screws.
• 35mm DIN-rail mounting.
• Single screw mounting.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low Voltage Directive
(50-1000Vac, 75-1500Vdc). Refer to Data Sheet: 8002 or contact
Bussmann Application Engineering at 636-527-1270 for more information.

Data Sheet: 4132
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Data Sheet: 4133

199

Bussmann®

British, European, & Canadian Standard Industrial Fuses

NH Low Voltage Fuse Links

NH_G

NH_M

NH_G-690

Voltage Rating: 500Vac
gL/gG Category
Agency Information:
IEC269, VDE, DIN43620 Part 1
A range of industrial fuse links for a
wide variety of applications.
The ordering code is made up as follows:

Voltage Rating: 500Vac
aM Category
Agency Information:
IEC269, VDE, DIN43620 Part 1
A range of industrial fuse links for the
protection of motor circuits.
The ordering code is made up as follows:

Rating

Rating

Voltage Rating: 690Vac/250Vdc
gL/gG Category
Agency Information:
IEC269, DIN43620 Part 1
A range of industrial fuse links for a
wide variety of applications where 690V
is needed.
The ordering code is made up as follows:

50

Product Code

Body

Category

NH

00

G

100

Product Code

Body

Category

NH

1

M

Rating
250

Type

Rating (A)

Fuse Body
Size

Type

C00

NHC00M

4, 6, 8, 10, 12, 16, 20, 25, 32,
40, 50
63, 80, 100

00

NHC00G

6, 10, 16, 20, 25, 32,
35, 40, 50, 63, 80, 100

NH00G

125, 160

00

NH00M

NH1G

6, 10, 16, 20, 25, 25, 32, 35,
40, 50, 63, 80, 100, 125, 160
200, 224, 225, 250

01

NH1M

35, 40, 50, 63, 80, 100, 125,
160, 200, 224, 250
315, 350, 400, 425

NH2G

NH3G

NH4AG

1
02
2

100, 125, 160, 200, 224, 250,
315, 350, 400
500, 630

03

800, 1000, 1250, 1600

4a

3

NH2M
NH3M

Ratings

Depth

Width

Overall
Length

NHC00G

6-100A

39.5

20.5

78.5

125 & 160A

38

29

78.5

NH00G
NH1G

6-160A

45

29

135

NH1G

200-250A

50

44.5

135

NH2G

35-250A

50

44.5

150

NH2G

315-425A

58

50

150

NH3G

100-400A

58

50

150

NH3G

500-630A

73

71

150

NH4AG

800-1000A

102

87

200

NH4AG

1250-1600A

110

95

200

Category

2

G-690

Fuse Body
Size

Rating (A)

C00

40, 50, 63, 80, 100, 125, 160

01

200, 250

02

125, 160, 200, 250

02

315, 400

2

315, 400

03

500, 630

3

Type
NH00G-690
NH1G-690

Fuse Body
Size

Rating (A)
10, 16, 20, 25, 32, 40,
50, 63, 80, 100

C00

32, 40, 50, 63, 80, 100

01

125, 160, 200, 200, 224, 225, 250

1

NH2G-690

100, 125, 160, 200, 224, 250,
315, 350, 400

2

NH3G-690

315, 350, 400, 500, 630

3

Dimensional Detail (mm)
Type

Ratings

Depth

Width

Ratings

Depth

Width

NH00G-690

10-100A

38

29

78.5

4-50A

39.5

20.5

78.5

NH1G-690

32-100A

45

29

135

NH00M

63-100A

38

29

78.5

NH1G-690

125-250A

50

44.5

135

NH1M

40-160A

45

29

135

NH2G-690

100-400A

50

44.5

150

NH1M

200-250A

50

44.5

135

NH3G-690

315-630A

58

50

150

NH2M

125-250A

50

44.5

150

Data Sheet: 4173

NH2M

315-400A

58

50

150

NH3M

315-400A

58

50

150

NH3M

500-630A

73

71

150

Data Sheet: 4173
CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

CE logo denotes compliance with European Union Low
Voltage Directive (50-1000Vac, 75-1500Vdc). Refer to
Data Sheet: 8002 or contact Bussmann Application
Engineering at 636-527-1270 for more information.

For additional information on the
IEC Cylindrical Fuse System, visit
www.bussmann.co.uk/products.htm

Data Sheet: 4173

200

Overall
Length

Overall
Length

NHC00M

Type

Body

NH

Dimensional Detail (mm)
Type

Dimensional Detail (mm)

Product Code

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

British, European, & Canadian Standard Industrial Fuses

Bussmann®

NH Fuse System

SB, TB

VLB

LBS

NH-LV Fuse Bases
Voltage Rating: 660Vac
Agency Information:
DIN43620/1, VDE
A range of single and triple pole fuse
bases with dimensions to DIN43620/1.
The ordering code is made up as
follows:
Rating: 400
Product Code: SB2

NH-LV Vertical Load Break Fuse
Switch Disconnector
Agency Information:
IEC, DIN43620/1
A range of LV Vertical Load Break Fuse
Switch Disconnectors to take NH Fuse
Links in sizes 00, 1, 2 and 3.
The ordering codes are shown in the
table below.

NH Fuse Switch Disconnector
Agency Information:
IEC, VDE, DIN
A range of Switch Fuses to take NH
fuse link sizes 00, 1, 2 and 3.
The ordering codes are shown in the
table below.

Type

Rating (A)

Type

Rating (A)

Fuse Body
Size

Rating (A)

Fuse Body
Size

LBS00

160

00

LBS1

250

1

400

2

630

3

Type

Fuse Body
Size*

VLB00

160

00

LBS2

250

1

LBS3

SB00

160

00

VLB1

SB1

250

1

VLB2

400

2

SB2

400

2

VLB3

630

3

SB3

630

3

Insulated and touch protected.

SB4

1250

4A

High Switching capacity.

TB00

160

0

Cable terminal top or bottom entry.

TB1

250

01

TB2

400

2

SB - Single Pole Base
TB - Triple Pole Base
*Size 00 is available with “V” shaped terminal lugs,
when ordering add “V” to part number i.e.
SB00V/TB00V

HRC LV Fuse Switch Disconnectors are available
for back panel mounting, size 00 can be adapted
for DIN rail mounting. A range of accessories are
also available.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

N.B. Size 1 bases will accommodate size 0 fuse
links.
Photo shown with side walls. To order side wall,
reference “PB” followed by the fuse body size (i.e.
PB00).
Vertical Fuse bases in size 00 to size 3 are
available, details upon request.
Universal Handle: Type 630 for sizes 00 to 3.
1250A size 4A Switchable base available.

CE logo denotes compliance with European
Union Low Voltage Directive (50-1000Vac,
75-1500Vdc). Refer to Data Sheet: 8002 or
contact Bussmann Application Engineering at
636-527-1270 for more information.

Data Sheet: 4169
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

201

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Accessories

Spare Fuseholders
• Durable construction using black thermoplastic with UL94-VO flammability
rating.
• Common mounting using #6 screws
or bolts on 5-inch centers.
• Dovetailed interlocking between
fuseholders simplifies installation
and reduces needed hardware.
• Common footprint allows for any
combination of fuseholders to be
mounted together.
• Built-in retaining clips secure fuses.
Catalog
Numbers

Capacity

TPSFH-T

10-position

GMT fuses

TPSFH-AS

6-position

TPA & TPS fuses

TPSFH-N30

4-position

Class R (1-30A) fuses

TPSFH-N60

1-position

Class R (35-60A) fuses

TPSFH-LB

1-position

Class L (70-250A)
series fuses

TPSFH-LC

1-position

Class L (300-600A)
series fuses

TPSFH-70

12-position

Series 70 fuses
(not shown)

FP-4

FP-3

FP-2

FP-6

FP-A3

Fusepullers
Cat.
No.

Application

SFC-FUSE-CAB
Carton
Qty.

Weight
Lbs.

Kg.

FP-2

⁄‹Ω£™∑ to ⁄‹Ω¡§∑ dia. fuses

1

.125 .057

FP-3

1∑ to 1‹Ω¢∑ dia. fuses

1

.173 .078

FP-4

1‹Ω¢∑ to 2⁄Ω™∑ dia. fuses

1

.53

FP-6

0-60A T-Tron fuses

1

.123 .056

FP-A3

Glass Tube & ATC fuses

10

0.08

.24
.04

Fuse pullers are only to be used when the associated circuit has been de-energized.

For Use With

Spare Fuse Cabinet
Size: 24∑ wide ≈ 30∑ high x 12∑ deep
• Five cubic feet of storage space.
• Sturdy storage cabinet conveniently
holds spare fuses.
• Constructed of heavy gauge steel.
• Cabinet door equipped with locking
handle.
• Durable baked ASA 61 grey enamel.
• Mounting holes with key slot 16
inches on center.

SFC SHELF
• Extra shelf for fuse cabinet.

FT-2

5TPH

Fuse Tester
24V Maximum
• Test automotive, glass tube and ferrule fuses up to 1‡Ω•∑ length.
• Batteries are included.
WARNING: DO NOT test electrical
fuses in the fuse panel.

Midget Fuse Spare Fuse Holder
Size: 2.98∑ wide ≈1.03∑ high ≈ .63∑
deep
• 5-position spare fuse holder for
midget size and class CC fuses
(⁄‹Ω£™∑ diameter).
• Constructed of grey thermoplastic.
• Adhesive tape on back for easy
mounting on cabinet doors.
Data Sheet: 1119

202

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Accessories

Fuse Reducers for Class J Dimension Fuses-LPJ, JKS
Fuse (Case)
Size

Equipment
Clip Size

Catalog No.
(Pair)
Reducer No.

*Carton
Weight
(Lbs.)

30A

60A

J-63

0.38

30A

100A

J-13

1.73

60A

100A

J-16

1.85

60A

†200A

J-26

2.55

100A

†200A

J-21

1.36

100A

†400A

J-41

4.90

200A

†400A

J-42

2.75

200A

†600A

J-62

1.80

400A

†600A

J-64

3.55

*Carton quantity—10 pair.
†Not for Bolt-on Applications.

Dummy Fuse “Neutrals” (These are not fuses)
Fuse Equivalent
Catalog Numbers
NNB
NNB-R
NNC
NTN-R-30
NTN-R-60
NTN-R-100
NTN-R-200
NTN-R-400
NTS-R-30
NTS-R-60
NTS-R-100
NTS-R-200
NTS-R-400
NTS-R-600

Voltage

Dimension

—
—
—

⁄‹Ω£™∑ ≈ 1⁄Ω™∑
Class CC
⁄Ω¢∑ ≈ 1⁄Ω¢∑

250V

600V

Amperes

Carton
Quantity

—
—
—

10
10
10

R/H

30A
60A
100A
200A
400A

10
10
5
1
1

R/H

30A
60A
100A
200A
400A
600A

10
10
1
1
1
1

Fuse Reducers for Class R Dimension Fuses
FRN-R, LPN-RK—FRS-R, LPS-RK
Catalog No. (Pairs)
Fuse (Case)
Size

Equipment
Clip Size

250V

600V

30A

60A

No. 263-R

No. 663-R

30A
60A

100A

No. 213-R
No. 216-R

No. 216-R
No. 616-R

60A
100A

200A

No. 226-R
No. 2621-R

No. 626-R
No. 2621-R

100A
200A

400A

No. 2641-R
No. 242-R

No. 2641-R
No. 642-R

100A
200A
400A

600A

No. 2661-R
No. 2662-R
No. 2664-R**

No. 2661-R
No. 2662-R
No. 2664-R**

**Single reducer only (pair not required).

Fuse Reducers for Class H & K Dimension Fuses
NON, REN—NOS, RES
Catalog No. (Pairs)
Equipment
Fuse (Case) Clip
Size
Size

250V
Reducer
No.

*Carton
Weight
(Lbs.)

600V
Reducer
No.

*Carton
Weight
(Lbs.)

30A

60A

No. 263

0.38

No. 663

1.00

30A

100A

No. 213

1.73

No. 216

1.73

60A

100A

No. 216

1.73

No. 616

1.85

60A

200A

No. 226

3.00

No. 626

3.33

100A

200A

No. 2621

1.63

No. 2621

1.63

100A

400A

No. 2641

4.90

No. 2641

4.90

200A

400A

No. 2642

3.50

No. 2642

3.50

100A

600A

No. 2661

8.70

No. 2661

8.70

200A

600A

No. 2662

6.85

No. 2662

6.85

400A

600A

No. 2664

4.45

No. 2664

4.45

*Carton quantity—10 pair.

Data Sheet: 1118
For complete specification data, call Bussmann Information Fax ~ 636.527.1450

203

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Accessories

Adapters for DIN and American Rails

TRON Clip-Clamps
Clamp Size
Volts
Amps
0-30A
250
35-60A
0-30A
600
35-60A
70-100A
250
110-200A
or
225-400A
600
450-600A

Cat. No.
No. 1
No. 2
No. 2
No. 4
No. 5
No. 6
No. 7
No. 8

Ctn.
Qty.
12
12
12
12
12
6
6
6

Weight
Lbs.
0.66
0.96
0.96
1.44
1.20
1.26
1.86
2.52

Kg
.30
.44
.44
.65
.54
.57
.84
1.14

• Buss DIN-Rail Adapters permit secure, positive snap-on
mounting of Buss 0 to 30 ampere fuseblocks (one, two, or
three pole) on the various size rails. (Rail mounting eliminates costly and time consuming drilling, tapping, and
screw mounting.)
• Molded from “Lexan™ 141”…a very high strength but
flexible material.
• Adapter mechanically locks into mounting hole of fuseblock
in seconds to become an integral part of the block.
• One adapter is required for Buss one and two pole blocks.
Two adapters are required for three pole blocks.
• With the exception of the 32mm DIN-rail, all blocks with
adapters can be removed from a rail simply by pulling up its
release tab.
• Use of rail end-stops on both sides of adapters is
recommended.
Adapter Catalog Data (For 0-30 Ampere Fuseblocks)
Fuseblock
Class
CC
G
*H (250V)
*R (250)
M Type

Rails
Type
DIN

American

Adapter
Size

15mm (Symm.)
32mm (Asymm.)
35mm (Symm.)
⁄‡Ω§¢∑ (Symm.)
(also 35mm DIN)

Color

Cat. No.

Black

DRA-1

Gray

DRA-2

Package Quantities: standard—10; bulk—100 (Cat. No. BK/DRA-1 or BK/DRA-2.)
*Mounting on 15mm rails is not recommended.
NOTE—New model Buss fuseblocks have elongated block-to-adapter mounting holes
(old style fuseblocks will not accept the rail adapters).

204

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Fuse Display Racks

Fusetron® View-Pack

Plug Fuse Display

Electronic Fuse Display

Fuse Display Rack
Catalog Symbol: FR-1000
The FR-1000 is a complete assortment
of Fusetron View-Packs with a display
rack. When you order a “FR-1000”,
you receive five each of the View-Packs
listed below, plus a heavy-duty wire
rack. The rack is designed to hang
from a pegboard or stand on a shelf.
The FR-1000 measures 32∑ wide,
18∑ tall and 10∑ deep.

Catalog Symbol: PFD-948
Sturdy plastic display features complete
assortment of plug fuses.
Each display comes with a set of labels
that permits customizing the product
mix.
Display measures 29∑ wide x 15∑ tall x
5∑ deep.

Catalog Symbol: No.15
A complete assortment of 125 volt and
250 volt fuses for electronic equipment.
The No. 15 display contains fifteen of
the most popular fuses for electronic
equipment, such as microwaves, computers, stereos, CB radios, or office
equipment. The sturdy wire rack holds
twelve cards of each fuse, and can be
hung from a pegboard or stood on a
shelf.
• Header card explains fuse types
and offers safety precautions.
• Sturdy wire rack can be hung from
a pegboard or stood on a shelf.
There is no charge for the rack, when
purchased with the display.

PFD-948 Display
Contents

Boxes*

Fuses

W-15

25

100

Fusetron View-Packs

W-20

25

100

Catalog Number

W-25

12

48

FRN-R-15-VP

W-30

25

100

FRN-R-20-VP

TL-15

25

100

FRN-R-25-VP

TL-20

25

100

FRN-R-30-VP

TL-30

25

100

FRN-R-35-VP

SL-15

25

100

FRN-R-40-VP

SL-20

25

100

FRN-R-45-VP

SL-30

25

100

No. 15 Display and Refills
Contents

Fuses/
Card

Cards/
Display

FRN-R-50-VP

*Each box contains 4 fuses.

BP/AGC-⁄Ω™

5

5

FRN-R-60-VP

Displays without fuses are also available. Order EMPTY-PFD to receive the
display only.

BP/AGC-1

5

10

BP/AGC-1⁄Ω™

5

5

BP/AGC-2

5

5

The PFD-948 is packed one per carton.
Carton size is 18⁄Ω™∑ ≈ 13⁄Ω™∑ ≈ 31⁄Ω¢∑,
weight is 75 lbs. The EMPTY-PFD is
also packed one per carton. Carton
size is 16∑ ≈ 6∑ ≈ 31⁄Ω¢∑, weight is 6 lbs.

BP/AGC-3

5

10

BP/AGC-4

5

5

BP/AGC-5

5

10

FRS-R-15-VP
FRS-R-20-VP
FRS-R-25-VP
FRS-R-30-VP
FRS-R-35-VP
FRS-R-40-VP
FRS-R-45-VP
FRS-R-50-VP
FRS-R-60-VP

BP/MDL-⁄Ω™

2

5

BP/MDL-1

2

5

BP/MDL-1⁄Ω™

2

5

BP/MDL-2

2

5

BP/MDL-3

2

5

BP/MDL-5

2

5

BP/ABC-10

2

5

BP/ABC-15

2

5

No. 15 (Display)

—

90

Display rack measures: 18⁄Ω¢∑ ≈ 10⁄Ω™∑ ≈ 24∑

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

205

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Service Kits

Low-Peak® Fuse

Fusetron® Fuse

Midget Fuse

Service Kit
Catalog Symbol: LPRK-28

Service Kit
Catalog Symbol: ERK-28

• Convenient, compact kit to hold
spare fuses.
• Sturdy nylon box with handle rugged
enough to withstand field use.
• Extra spaces and changeable compartments make it easy to customize
for your particular need.

• Convenient, compact kit to hold
spare fuses.
• Sturdy nylon box with handle rugged
enough to withstand field use.
• Extra spaces and changeable compartments make it easy to customize
for your particular need.

Emergency Kit
Quick Service Replacement for
⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuses
Catalog Symbol: No. 36
• A sturdy nylon box is ideal for factory
or service truck use.
• Cross reference makes it easy to
install correct fuse in any application.
• Free fuse puller enclosed in box.

Contents

Contents

Contents

(2) LPN-RK-3¤Ω¡º SP

(2) LPN-RK-40 SP

(2) FRN-R-3¤Ω¡º

(2) FRN-R-40

(2) LPN-RK-6⁄Ω¢ SP

(2) LPN-RK-50 SP

(2) FRN-R-6⁄Ω¢

(2) FRN-R-50

(2) LPN-RK-10 SP

(3) LPN-RK-60 SP

(2) FRN-R-10

(3) FRN-R-60

(2) LPN-RK-15 SP

(2) LPN-RK-100 SP

(2) FRN-R-15

(2) FRN-R-100

(3) LPN-RK-20 SP

(2) No. 263-R Reducers

(3) FRN-R-20

(2) No. 263-R Reducers

(2) LPN-RK-25 SP

(2) No. 1 Clip Clamps

(2) FRN-R-25

(2) No. 1 Clip Clamps

(4) LPN-RK-30 SP

(2) No. 2 Clip Clamps

(4) FRN-R-30

(2) No. 2 Clip Clamps

(2) LPN-RK-35 SP

(1) FP-2 Fusepuller

(2) FRN-R-35

(2) FNQ-R-⁄Ω™

(2) KTK-R-1

(2) FNQ-R-1

(2) KTK-R-2

(2) FNQ-R-2

(2) KTK-R-3

(2) FNQ-R-3

(2) KTK-R-5

(2) FNQ-R-4

(2) KTK-R-6

(2) FNQ-R-5

(2) KTK-R-10

(2) FNQ-10

(2) KTK-R-15

(2) FNQ-15

(2) KTK-R-20

(2) FNQ-20

(2) KTK-R-30

(1) FP-2

Kit size: 10‡Ω•∑ ≈ 6fiΩ•∑ ≈ 1‹Ω¢∑.

206

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Service Kits

Small Dimension Fuse

Small Dimension Fuse

5mm ≈ 20mm Fuse

Assortment Kit
Catalog Symbol: No. 270
Voltage Rating: 125V and 250V
Contains 270 assorted fuses plus
fuseholders, fuseblocks and fuse clips
to fit most electronic equipment.

Assortment Kit
Catalog Symbol: No. 140
Voltage Rating: 125V & 250V
Contains 140 assorted fuses plus
fuseholders, fuseblocks and fuse clips
to fit most electronic equipment.

Electronic Fuse Assortment

Assortment Kit
Catalog Symbol: No. 220
Voltage Rating: 125V & 250V
A complete assortment of 125V and
250V 5mm x 20mm size fuses for the
repair of both electrical and electronic
devices.

Electronic Fuse Assortment

(5) MDL-⁄Ω•

(5) ABC-10

(5) MDL-⁄Ω¢

(5) ABC-15

(5) MDL-⁄Ω™

(5) ABC-20

(5) MDL-‹Ω¢

(5) ABC-30

(5) MDL-1

(5) GMA-250mA

(5) MDL-1⁄Ω™

(5) GMA-500mA

(5) MDL-2

(5) GMA-1A

(5) MDL-3

(5) GMA-2A

(5) MDL-4

(5) GMA-3A

(5) MDL-5

(5) GMA-4A

(5) MDL-6

(5) GMA-6A

(5) MDA-8

(5) GMC-1A

(5) MDA-10

(5) GMC-2A

(5) MDA-15

(5) GMC-3A

(5) MDA-20

(5) GMC-4A

(5) MDA-30

(5) GMC-6A

(5) AGC-⁄Ω•

(5) AGC-V-⁄Ω™

(5) AGC-⁄Ω¢

(5) AGC-V-1

(5) AGC-⁄Ω™

(5) AGC-V-2

(5) AGC-‹Ω¢

(5) AGC-V-3

(5) AGC-1

(5) MDL-V-⁄Ω™

(5) AGC-1⁄Ω™

(5) MDL-V-1

(5) AGC-2

(5) MDL-V-2

(5) AGC-2⁄Ω™

(5) MDL-V-3

(5) AGC-3

(1) S-8202-2

(5) AGC-4

(1) HTB-26I

(5) AGC-5

(1) HTB-28M

(5) AGC-6

(2) Pr. 4121 Fuseclips

(5) AGC-7

(2) HHB

Contents

(5) MDL-⁄Ω™

(5) AGC-1⁄Ω™

(5) MDL-1

(5) AGC-2

(5) MDL-1⁄Ω™

(5) AGC-3

(5) MDQ-2

(5) MTH-4

(5) MDQ-3

(5) MTH-5

GDA

630ma, 1, 2, 3.15, 5, 6.3

(5) MDQ-4

(5) MTH-6

GDB

630ma, 2, 3.15, 4

(5) MDQ-5

(5) MTH-7

GMC

(5) MDQ-6

(5) MTH-8

500ma, 750ma, 1, 2,
2.5, 3, 3.15, 4, 5, 6.3

(5) MDA-8

(5) ABC-10

GMD

200ma, 500ma, 1, 1.6, 2, 3

(5) MDA-10

(5) ABC-15

GDC

(5) MDA-15

(5) ABC-20

250ma, 500ma, 1, 1.6,
2, 3.15, 4, 5

(5) MDA-20

(5) ABC-30

(5) MDA-30

(2) Pr. #4121 Fuseclips

(5) AGC-⁄Ω¢

(2) HHB

(5) AGC-⁄Ω™

(1) FP-A3

Product
Type
GMA

Ampere Ratings
Contains 5 each
250ma, 500ma, 1, 1.5,
2, 2.5, 3, 4, 5, 10

HTB-28m,
FP-A3

(5) AGC-1

(5) AGC-8

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

207

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Fuse Display Racks

No. 2880
Empty Counter or Wall Stock
Display Rack
• Holds 2880 fuses (574 boxes of
5 each).
• Six removable sections with four
channels. Units may be interlocked
without screws.

Electronic Fuse Display

No. 200 & No. 201

Catalog Symbol: No. 205
Compact display of 125V and
250V fuses.
Size: 6‹Ω¢∑ W ≈ 16∑ H x 4∑ D

Glass Tube and Blade-Type
Automotive Fuses
The “200”—40 boxes (172 fuses).
Size: 4∑ ≈ 6‹Ω¢∑ x 10∑ (270 cu. in.)

Fuse

Quantity

Fuse

Quantity

Fuse

Quantity

Fuse

Quantity

AGC-⁄Ω™
AGC-1
AGC-1⁄Ω™
AGC-2
AGC-3
AGC-4
AGC-5
AGC-6
AGC-7
AGC-8
AGC-10
ABC-10
ABC-15
ABC-20
MDL⁄Ω™

5
10
5
10
10
5
10
5
5
5
5
5
15
5
5

MDL-1
MDL-1⁄Ω™
MDL-2
MDL-3
MDL-4
MDL-5
MDL-6
MDL-7
MDL-8
GLH-7
GMA-500mA
GMA-1A
GMA-2A
GMA-3A
GMA-5A

10
5
10
10
5
5
5
5
5
15
5
5
5
5
5

AGC-1
AGC-2
AGC-3
AGC-5
AGC-7⁄Ω™
AGC-10
AGC-15
AGC-20
AGC-25
AGC-30
ATC-3
ATC-4
ATC-5
ATC-7⁄Ω™
ATC-10
ATC-15
ATC-20
ATC-25
ATC-30

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
10
5
5

ATM-2
ATM-3
ATM-4
ATM-5
ATM-7⁄Ω™
ATM-10
ATM-15
ATM-20
ATM-25
ATM-30
GBC-8
MAX-20
MAX-30
MAX-40
MAX-50
MAX-60
SFE-14
SFE-20

5
5
5
5
5
5
5
5
5
5
5
5
5
2
1
2
5
5

The “201”—40 boxes (172 fuses).
Comes in handy, clear plastic service kit.
Fuse assortment same as the “200”.
3∑ ≈ 4∑ x 10∑ (142.5 cu. in.)

Christmas Light Fuses
and Displays
Bussmann offers a comprehensive line
of replacement fuses for all Christmas
tree lights and decorative light
products.
Display Cartons
Part No.
BP/AGX-7X5
BP/GLH-7X5
BP/MAS-3X5
BP/XMAS-6F

Carton
Quantity

Description
5 AGX-7A, 125V Fuses
⁄Ω¢∑ ≈ 1∑ Glass Tube
5 GLH-7A, 125V Fuses
⁄Ω¢∑ ≈ 1⁄Ω¢∑ Glass Tube
5 MAS-3A, 125V Fuses
3.6mm x 10mm Glass Tube
Assortment: 6 Fuses
(2 ea. AGX-7, GLH-7, MAS-3)

20 Cards
20 Cards
20 Cards
20 Cards

Clip Strip
CS/XMAS-6F

Assortment: 6 Fuses
20 Cards
(2 ea. AGX-7, GLH-7, MAS-3)
Note: Order by the card (each in multiples of 20).

Package Specifications
Card Size

208

Display Carton

Part No.

H

W

D

H

W

Weight

BP/AGX-7X5
BP/GLH-7X5
BP/MAS-3X5
BP/XMAS-6F
CS/XMAS-6F

4‹Ω¢∑
4‹Ω¢∑
4‹Ω¢∑
4‹Ω¢∑
4‹Ω¢∑

2‹Ω¢∑
2‹Ω¢∑
2‹Ω¢∑
2‹Ω¢∑
2‹Ω¢∑

7⁄Ω¢∑
7⁄Ω¢∑
7⁄Ω¢∑
7⁄Ω¢∑
6⁄Ω™∑

6⁄Ω¢∑
6⁄Ω¢∑
6⁄Ω¢∑
6⁄Ω¢∑
2‡Ω•∑

5‹Ω¢∑
5‹Ω¢∑
5‹Ω¢∑
5‹Ω¢∑
6⁄Ω¢∑

1 lb. 10 oz.
1 lb. 10 oz.
1 lb. 10 oz.
1 lb. 10 oz.
1 lb. 4 oz.

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

Bussmann®

Fuse Accessories, Displays, Kits, Etc.

Fuse Display Racks

FSD

FDM-1
Fuse Display Merchandiser
• Bussmann tilt-bin display maximizes your space and stimulates impulse purchases.
• Interlocking bins can be stacked or mounted on peg board.
• Header card easily attaches with plastic push pegs.
• Provides a flexible system to best fit your needs and space
requirements.
• The tilt bins are available in five and six bin models.
Fuse Display Merchandiser will consist of any number of either
size bins; header card push pegs to attach and part number
labels.
Part Number

Key Features & Benefits:
• Prominent “Silent Salesman”.
• Sturdy Steel Construction.
• Selection of fastest selling sizes and amps.
• Flip chart for applications, cross referencing
and fuse types.
• Clear tilt bins allow for quick identification,
easy access, inventory restocking.
• Heavy duty casters allow for easy repositioning.
• Modular system provides flexibility for growth
by joining two or more units together.
(Back-to-back or side-by-side).
• Product part number adhesive labels.
• Standard Gondola Measures:
24" wide x 66" tall x 21⁄Ω™" deep
Part
Number

Carton
Quantity

Part
Number

Carton
Quantity

Part
Number

Carton
Quantity

Description

FNQ-R-1/4

10

FNM-15

10

NON-35

10

1A9721

5 Bin Display

23fiΩ• long x 6⁄Ω™ tall x 5⁄Ω™ deep

FNQ-R-1/2

10

LP-CC-5

10

NON-40

10

1A9722

6 Bin Display

23fiΩ• long x 4⁄Ω™ tall x 3fiΩ• deep

FNQ-R-1

10

LP-CC-10

10

NON-45

10

FNQ-R-1-1/2

10

LP-CC-15

10

NON-50

10

FNQ-R-2

10

LP-CC-20

10

NON-60

10

FNQ-R-3

10

LP-CC-30

10

T-15

4

FNQ-R-4

10

FRN-R-5

10

T-20

4

FNQ-R-5

10

FRN-R-10

10

T-30

4

FNQ-R-10

10

FRN-R-15

10

W-15

4

FNQ-15

10

FRN-R-20

10

W-20

FNQ-20

10

FRN-R-25

10

FRS-R-5

10

FNQ-25

10

FRN-R-30

10

FRS-R-10

10

FNQ-30

10

FRN-R-35

10

FRS-R-15

10

FP2

10

FRN-R-40

10

FRS-R-20

10

FP3

10

FRN-R-45

10

FRS-R-25

10

KTK-R-5

10

FRN-R-50

10

FRS-R-30

10

KTK-R-10

10

FRN-R-60

10

FRS-R-35

10

KTK-R-15

10

NON-3

10

FRS-R-40

10

KTK-R-20

10

NON-6

10

FRS-R-50

10

KTK-R-30

10

NON-10

10

FRS-R-60

10

FNM-2

10

NON-15

10

FRS-R-100

1

FNM-5

10

NON-20

10

FRS-R-200

1

FNM-10

10

NON-30

10

For complete specification data, call Bussmann Information Fax ~ 636.527.1450

4

209

Fuse Technology

Circuit Protection
Electrical distribution systems are often quite complicated. They
cannot be absolutely fail-safe. Circuits are subject to destructive
overcurrents. Harsh environments, general deterioration, accidental damage, damage from natural causes, excessive expansion, and/or overloading of the electrical distribution system are
factors which contribute to the occurrence of such overcurrents.
Reliable protective devices prevent or minimize costly damage to
transformers, conductors, motors, and the other many components and loads that make up the complete distribution system.
Reliable circuit protection is essential to avoid the severe monetary losses which can result from power blackouts and prolonged
downtime of facilities. It is the need for reliable protection, safety,
and freedom from fire hazards that has made the fuse a widely
used protective device.
Overcurrents
An overcurrent is either an overload current or a short-circuit current. The overload current is an excessive current relative to normal operating current, but one which is confined to the normal
conductive paths provided by the conductors and other components and loads of the distribution system. As the name implies,
a short-circuit current is one which flows outside the normal conducting paths.
Overloads
Overloads are most often between one and six times the normal
current level. Usually, they are caused by harmless temporary
surge currents that occur when motors are started-up or transformers are energized. Such overload currents, or transients, are
normal occurrences. Since they are of brief duration, any temperature rise is trivial and has no harmful effect on the circuit
components. (It is important that protective devices do not react
to them.)
Continuous overloads can result from defective motors (such as
worn motor bearings), overloaded equipment, or too many loads
on one circuit. Such sustained overloads are destructive and
must be cut off by protective devices before they damage the
distribution system or system loads. However, since they are of
relatively low magnitude compared to short-circuit currents,
removal of the overload current within minutes will generally prevent equipment damage. A sustained overload current results in
overheating of conductors and other components and will cause
deterioration of insulation, which may eventually result in severe
damage and short-circuits if not interrupted.
Short-Circuits
Whereas overload currents occur at rather modest levels, the
short-circuit or fault current can be many hundred times larger
than the normal operating current. A high level fault may be
50,000A (or larger). If not cut off within a matter of a few thousandths of a second, damage and destruction can become

210

Bussmann®

rampant—there can be severe insulation damage, melting of
conductors, vaporization of metal, ionization of gases, arcing,
and fires. Simultaneously, high level short-circuit currents can
develop huge magnetic-field stresses. The magnetic forces
between bus bars and other conductors can be many hundreds
of pounds per linear foot; even heavy bracing may not be adequate to keep them from being warped or distorted beyond
repair.
Fuses
The fuse is a reliable overcurrent protective device. A “fusible” link
or links encapsulated in a tube and connected to contact terminals comprise the fundamental elements of the basic fuse.
Electrical resistance of the link is so low that it simply acts as a
conductor. However, when destructive currents occur, the link
very quickly melts and opens the circuit to protect conductors
and other circuit components and loads. Fuse characteristics are
stable. Fuses do not require periodic maintenance or testing.
Fuses have three unique performance characteristics:
1. Modern fuses have an extremely “high interrupting
rating”—can withstand very high fault currents without
rupturing.
2. Properly applied, fuses prevent “blackouts.” Only the
fuse nearest a fault opens without upstream fuses
(feeders or mains) being affected—fuses thus provide
“selective coordination.” (These terms are precisely
defined in subsequent pages.)
3. Fuses provide optimum component protection by
keeping fault currents to a low value…They are said to
be “current limiting.”
Voltage Rating
The voltage rating of a fuse must be at least equal to or greater
than the circuit voltage. It can be higher but never lower. For
instance, a 600V fuse can be used in a 208V circuit.
The voltage rating of a fuse is a function of its capability to
open a circuit under an overcurrent condition. Specifically,
the voltage rating determines the ability of the fuse to suppress
the internal arcing that occurs after a fuse link melts and an arc
is produced. If a fuse is used with a voltage rating lower than the
circuit voltage, arc suppression will be impaired and, under some
fault current conditions, the fuse may not clear the overcurrent
safely. Special consideration is necessary for semiconductor fuse
and medium voltage fuse applications, where a fuse of a certain
voltage rating is used on a lower voltage circuit.
Ampere Rating
Every fuse has a specific ampere rating. In selecting the ampere
rating of a fuse, consideration must be given to the type of load
and code requirements. The ampere rating of a fuse normally
should not exceed the current carrying capacity of the circuit. For

Bussmann®

Fuse Technology

instance, if a conductor is rated to carry 20A, a 20A fuse is the
largest that should be used. However, there are some specific
circumstances in which the ampere rating is permitted to be
greater than the current carrying capacity of the circuit. A typical
example is the motor circuit; dual-element fuses generally are
permitted to be sized up to 175% and non-time-delay fuses up
to 300% of the motor full-load amperes. As a rule, the ampere
rating of a fuse and switch combination should be selected at
125% of the continuous load current (this usually
corresponds to the circuit capacity, which is also selected at
125% of the load current). There are exceptions, such as when
the fuse-switch combination is approved for continuous operation at 100% of its rating.
Interrupting Rating
A protective device must be able to withstand the destructive
energy of short-circuit currents. If a fault current exceeds the
capability of the protective device, the device may actually rupture, causing additional damage. Thus, it is important when
applying a fuse or circuit breaker to use one which can sustain
the largest potential short-circuit currents. The rating which
defines the capacity of a protective device to maintain its integrity when reacting to fault currents is termed its “interrupting
rating”. The interrupting rating of most branch-circuit, molded
case, circuit breakers typically used in residential service entrance
panels is 10,000A. (Please note that a molded case
circuit breaker’s interrupting capacity will typically be lower than
its interrupting rating.) Larger, more expensive circuit breakers
may have interrupting ratings of 14,000A or higher. In contrast,
most modern, current-limiting fuses have an interrupting rating of
200,000 or 300,000A and are commonly used to protect the
lower rated circuit breakers. The National Electrical Code,
Section 110-9, requires equipment intended to break current at
fault levels to have an interrupting rating sufficient for the current
that must be interrupted.
Selective Coordination – Prevention of Blackouts
The coordination of protective devices prevents system power
outages or blackouts caused by overcurrent conditions. When
only the protective device nearest a faulted circuit opens and
larger upstream fuses remain closed, the protective devices are
“selectively” coordinated (they discriminate). The word “selective”
is used to denote total coordination…isolation of a faulted circuit
by the opening of only the localized protective device.

KRP-C
1200SP

LPS-RK
600SP

LPS-RK
200SP

2:1 (or more)
2:1 (or more)
This diagram shows the minimum ratios of ampere ratings of LOW-PEAK
YELLOW fuses that are required to provide “selective coordination”
(discrimination) of upstream and downstream fuses.

Unlike electro-mechanical inertial devices (circuit breakers), it is a
simple matter to selectively coordinate fuses of modern design.
By maintaining a minimum ratio of fuse-ampere ratings between
an upstream and downstream fuse, selective coordination is
assured.
Current Limitation – Component Protection
Areas within waveform
loops represent destructive
energy impressed upon
circuit components

Normal
load current

Initiation of
short-circuit
current

Circuit breaker trips
and opens short-circuit
in about 1 cycle

A non-current-limiting protective device, by permitting a shortcircuit current to build up to its full value, can let an immense amount of
destructive short-circuit heat energy through before opening the circuit.

Fuse opens and clears
short-circuit in less
than cycle

A current-limiting fuse has such a high speed of response that it cuts off a
short-circuit long before it can build up to its full peak value.

If a protective device cuts off a short-circuit current in less than
one-quarter cycle, before it reaches its total available (and highly
destructive) value, the device is a “current-limiting” device. Most
modern fuses are current-limiting. They restrict fault currents to
such low values that a high degree of protection is given to circuit
components against even very high short-circuit currents. They
permit breakers with lower interrupting ratings to be used. They
can reduce bracing of bus structures. They minimize the need of
other components to have high short-circuit current “withstand”
ratings. If not limited, short-circuit currents can reach levels of
30,000 or 40,000A or higher in the first half cycle (.008 seconds,
60 hz) after the start of a short-circuit. The heat that
can be produced in circuit components by the immense energy
of short-circuit currents can cause severe insulation damage or
even explosion. At the same time, huge magnetic forces
developed between conductors can crack insulators and distort
and destroy bracing structures. Thus, it is important that
a protective device limit fault currents before they reach their
full potential level.

211

Fuse Technology

Bussmann®

Operating Principles of Bussmann® Fuses
The principles of operation of the modern, current-limiting Buss
fuses are covered in the following paragraphs.
Non-Time-Delay Fuses
The basic component of a fuse is the link. Depending upon the
ampere rating of the fuse, the single-element fuse may have one
or more links. They are electrically connected to the end blades (or
ferrules) (see Figure 1) and enclosed in a tube or cartridge surrounded by an arc quenching filler material. BUSS® LIMITRON®
and T-TRON® fuses are both single-element fuses.
Under normal operation, when the fuse is operating at or near its
ampere rating, it simply functions as a conductor. However, as
illustrated in Figure 2, if an overload current occurs and persists for
more than a short interval of time, the temperature of the link eventually reaches a level which causes a restricted segment of the link
to melt. As a result, a gap is formed and an electric arc established. However, as the arc causes the link metal to burn back, the
gap becomes progressively larger. Electrical resistance of the arc
eventually reaches such a high level that the arc cannot be sustained and is extinguished. The fuse will have then completely cut
off all current flow in the circuit. Suppression or quenching of the
arc is accelerated by the filler material. (See Figure 3.)
Single-element fuses of present day design have a very high
speed of response to overcurrents. They provide excellent shortcircuit component protection. However, temporary, harmless
overloads or surge currents may cause nuisance openings unless
these fuses are oversized. They are best used, therefore, in circuits not subject to heavy transient surge currents and the temporary over-load of circuits with inductive loads such as motors,
transformers, solenoids, etc. Because single-element, fast-acting
fuses such as LIMITRON and T-TRON fuses have a high speed of
response to short-circuit currents, they are particularly suited for
the protection of circuit breakers with low interrupting ratings.
Whereas an overload current normally falls between one and
six times normal current, short-circuit currents are quite high.
The fuse may be subjected to short-circuit currents of 30,000
or 40,000A or higher. Response of current limiting fuses to such
currents is extremely fast. The restricted sections of the fuse link
will simultaneously melt (within a matter of two or three-thousandths of a second in the event of a high-level fault current).
The high total resistance of the multiple arcs, together with the
quenching effects of the filler particles, results in rapid arc suppression and clearing of the circuit. (Refer to Figures 4 & 5) Shortcircuit current is cut off in less than a half-cycle, long before the
short-circuit current can reach its full value (fuse operating in its
current limiting range).

212

Figure 1. Cutaway view of typical single-element fuse.

Figure 2. Under sustained overload, a section of the link melts and an
arc is established.

Figure 3. The “open” single-element fuse after opening a circuit
overload.

Figure 4. When subjected to a short-circuit current, several
sections of the fuse link melt almost instantly.

Figure 5. The “open” single-element fuse after opening a short circuit.

Bussmann®

Fuse Technology
Bussmann Dual-Element Fuses
®

There are many advantages to using these fuses. Unlike single-element fuses, the Bussmann® dual-element, time-delay fuses can be sized closer to provide both high performance shortcircuit protection and reliable overload protection in circuits subject to temporary overloads and surge currents. For ac motor loads, a single-element fuse may need to be sized at 300% of an
a.c. motor current in order to hold the starting current. However, dual-element, time delay fuses can be sized much closer to motor loads. For instance, it is generally possible to size FUSETRON®
Dual-Element Fuses, FRS-R and FRN-R and LOW-PEAK® Dual-Element Fuses, LPS-RK_SP and LPN-RK_SP, at 125% and 130% of motor full load current, respectively. Generally, the LOWTM
PEAK® Dual-Element Fuses, LPJ_SP, and CUBEFuse , TCF, can be sized at 150% of motor full load amperes. This closer fuse sizing may provide many advantages such as: (1)
smaller fuse and block, holder or disconnect ampere rating and physical size, (2) lower cost due to lower ampere rated devices and possibly smaller required panel space, (3) better
short-circuit protection – less short-circuit current let-through energy, and (4) potential reduction in the arc flash hazard.
Insulated end-caps to help prevent
accidental contact with live parts.

Filler material
Figure 6. This is the LPS-RK100SP, a 100A, 600V LOW-PEAK®, Class RK1, Dual-Element Fuse that has excellent time-delay, excellent current-limitation and a 300,000A interrupting rating. Artistic liberty is taken to illustrate the internal portion of this fuse. The real fuse has a non-transparent tube and special small granular, arc-quenching material completely filling the
internal space.
Small volume of metal to vaporize
Short-circuit element

Overload element
Figure 7. The true dual-element fuse has distinct and separate overload
element and short-circuit element.

Figure 9. Short-circuit operation: Modern fuses are designed with minimum metal in the
restricted portions which greatly enhance their ability to have excellent current-limiting
characteristics – minimizing the short circuit let-through current. A short-circuit
current causes the restricted portions of the short-circuit element to vaporize and arcing
commences. The arcs burn back the element at the points of the arcing. Longer arcs result,
which assist in reducing the current. Also, the special arc quenching filler material contributes to extinguishing the arcing current. Modern fuses have many restricted portions,
swhich results in many small arclets – all working together to force the current to zero.

Before

Filler quenches the arcs

Spring

After
Figure 8. Overload operation: Under sustained overload conditions, the trigger spring
fractures the calibrated fusing alloy and releases the “connector”. The insets represent a
model of the overload element before and after. The calibrated fusing alloy connecting the
short-circuit element to the overload element fractures at a specific temperature due to a
persistant overload current. The coiled spring pushes the connector from the short-circuit
element and the circuit is interrupted.

Figure 10. Short-circuit operation: The special small granular, arc-quenching material
plays an important part in the interruption process. The filler assists in quenching the arcs;
the filler material absorbs the thermal energy of the arcs, fuses together and creates an
insulating barrier. This process helps in forcing the current to zero. Modern current-limiting fuses, under short-circuit conditions, can force the current to zero and complete the
interruption within a few thousandths of a second.

When the short-circuit current is in the current-limiting range of a fuse, it is not possible for the full available short-circuit current to flow through the fuse – it’s a matter of physics. The small
restricted portions of the short-circuit element quickly vaporize and the filler material assists in forcing the current to zero. The fuse is able to “limit” the short-circuit current.
Overcurrent protection must be reliable and sure. Whether it is the first day of the electrical system or thirty or more years later, it is important that overcurrent protective devices perform under
overload or short-circuit conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles.

213

Bussmann®

Fuse Technology

This particular plot reflects the characteristics of a 200A, 250V,
LOW-PEAK YELLOW dual-element fuse. Note that at the 1,000A
overload level, the time interval which is required for the fuse to
open is 10 seconds. Yet, at approximately the 2,200A overcurrent level, the opening (melt) time of a fuse is only 0.01 seconds.
It is apparent that the time intervals become shorter as the overcurrent levels become larger. This relationship is termed an
inverse time-to-current characteristic. Time-current curves are
published or are available on most commonly used fuses showing “minimum melt,” “average melt” and/or “total clear” characteristics. Although upstream and downstream fuses are easily
coordinated by adhering to simple ampere ratios, these time-current curves permit close or critical analysis of coordination.
Better Motor Protection in Elevated Ambients
The derating of dual-element fuses based on increased ambient
temperatures closely parallels the derating curve of motors in elevated ambient. This unique feature allows for optimum protection
of motors, even in high temperatures.
Affect of ambient temperature on operating characteristics of FUSETRON

400
300
200
LOW-PEAK YELLOW
LPN-RK200 SP (RK1)

100
80
60
40
30
20
10
8
6
TIME IN SECONDS

Fuse Time-Current Curves
When a low level overcurrent occurs, a long interval of time will
be required for a fuse to open (melt) and clear the fault. On the
other hand, if the overcurrent is large, the fuse will open very
quickly. The opening time is a function of the magnitude of the
level of overcurrent. Overcurrent levels and the corresponding
intervals of opening times are logarithmically plotted in graph
form as shown to the right. Levels of overcurrent are scaled on
the horizontal axis; time intervals on the vertical axis. The curve is
thus called a “time-current” curve.

4
3
2
1
.8
.6
.4
.3
.2

150
140
PERCENT OF RATING OR
OPENING TIME

130

.1
.08
.06

Affect on Carrying
Capacity Rating

120
110
100

.04

90
80
70

.03

Affect on
Opening Time

.02

60
50

AMBIENT

and LOW-PEAK YELLOW Dual-Element Fuses.

214

176°F
(80°C)

212°F
(100°C)

CURRENT IN AMPERES

6,000
8,000
10,000

140°F
(60°C)

3,000
4,000

104°F
(40°C)

2,000

68°F
(20°C)

600
800
1,000

–32°F
(0°C)

300
400

–76°F
–40°F
–4°F
(–60°C) (–40°C) (–20°C)

200

30

100

.01

40

Fuse Technology

Bussmann®

Better Protection Against Motor Single Phasing
When secondary single-phasing occurs, the current in the remaining phases increases to approximately 200% rated full load
current. (Theoretically 173%, but change in efficiency and power
factor make it about 200%.) When primary single-phasing
occurs, unbalanced voltages occur on the motor circuit causing
currents to rise to 115%, and 230% of normal running currents
in delta-wye systems.
Dual-element fuses sized for motor running overload protection
will help to protect motors against the possible damages of
single-phasing.
Classes of Fuses
Safety is the industry mandate. However, proper selection, overall
functional performance and reliability of a product are factors
which are not within the basic scope of listing agency activities.
In order to develop its safety test procedures, listing agencies
develop basic performance and physical specifications or standards for a product. In the case of fuses, these standards have
culminated in the establishment of distinct classes of low-voltage
(600V or less) fuses; classes RK1, RK5, G, L, T, J, H and CC being
the more important.
The fact that a particular type of fuse has, for instance, a classification of RK1, does not signify that it has the identical function or
performance characteristics as other RK1 fuses. In fact, the LIMITRON® non-time-delay fuse and the LOW-PEAK YELLOW™
dual-element, time-delay fuse are both classified as RK1.
Substantial differences in these two RK1 fuses usually requires
considerable difference in sizing. Dimensional specifications of
each class of fuse does serve as a uniform standard.

In the above illustration, a grooved ring in one ferrule provides the
rejection feature of the Class R fuse in contrast to the lower
interrupting rating, non-rejection type.
Branch-Circuit Listed Fuses
Branch-circuit listed fuses are designed to prevent the installation
of fuses that cannot provide a comparable level of protection to
equipment.
The characteristics of Branch-circuit fuses are:
1. They must have a minimum interrupting rating of 10,000A
2. They must have a minimum voltage rating of 125V.
3. They must be size rejecting such that a fuse of a lower
voltage rating cannot be installed in the circuit.
4. They must be size rejecting such that a fuse with a current
rating higher than the fuseholder rating cannot be installed.

Class R Fuses
Class R (“R” for rejection) fuses are high performance, ⁄Ω¡º to 600A
units, 250V and 600V, having a high degree of current limitation
and a short-circuit interrupting rating of up to 300,000A (rms symmetrical). BUSS Class R's include Classes RK1 LOW-PEAK YELLOW™ and LIMITRON® fuses, and RK5 FUSETRON® fuses. They
have replaced BUSS K1 LOW-PEAK and LIMITRON fuses and
K5 FUSETRON fuses. These fuses are identical, with the exception of a modification in the mounting configuration called a “rejection feature”. This feature permits Class R fuses to be mounted in
rejection type fuseclips. “R” type fuseclips prevent older type
Class H, ONE-TIME and RENEWABLE fuses from being installed.
The use of Class R fuseholders is thus an important safeguard.
The application of Class R fuses in such equipment as disconnect
switches permits the equipment to have a high interrupting rating.
NEC Articles 110-9 and 230-65 require that protective devices
have adequate capacity to interrupt short-circuit currents. Article
240-60(b) requires fuseholders for current-limiting fuses to reject
non-current-limiting type fuses.

215

Transformers
(N.E.C. 450-3)

216

600V
Nominal
or Less

Over
600V
Nominal

Primary
and
Secondary
Protection

Primary
Protection
Only

Un-Supervised
Installations

Supervised
Installations

With
Thermal
Overload
Protection

Without
Thermal
Overload
Protection

Based on 1996 N.E.C.®

Transformer
Impedance of
More Than 6%
But Less
Than 10%

Transformer
Impedance of
6% or Less

Rated secondary current 9
amps or greater.

Rated secondary current less
than 9 amps.

Rated secondary current 9
amps or greater.

F

E

D

F

E

D

C

C
Primary and secondary
fuses at 125% of
primary and secondary
F.L.A. or next size
larger.

B

Rated secondary current 9
amps or greater.
Rated secondary current less
than 9 amps.

B

A

Rated secondary current less
than 9 amps.

125% or next size larger

125% or next size larger

Rated primary current
greater than or equal to
2 amps but less than 9 amps.
Rated primary current greater
than or equal to 9 amps.

125% or next size larger

(LPN-RK_SP, LPS-RK_SP,
FRN-R, FRS-R)

A

Secondary 600V or
Below

250%
250%
600%
600%
400%
400%

167% or next size smaller.
125% or next size larger.*
167% or next size smaller.
125% or next size larger.*
167% or next size smaller.
125% or next size larger.*
*When 125% of F.L.A. corresponds to
a standard rating, the next larger size
is not permitted.

A
B
C
D
E
F

Maximum Fuse Size
% of Primary
% of Secondary
F.L.A. (Or next
F.L.A.
size smaller.)

Max. of 125% or next larger*.

Max. 300% or next size smaller. (See
N.E.C. 430-72(c) for control circuit
transformer maximum of 500%.
Max. 167% or next size smaller.

N.E.C. MAXIMUMS
(All Fuse Types Shown)

Secondary at code max. of
125% or next standard size if
125% does not correspond to
a standard rating.

Secondary at code max. of
225% or next standard size if
225% does not correspond to
a standard rating.

Secondary Over 600V

OPTIMUM PROTECTION

Primary at code max. of 300%
or next standard size if 300%
does not correspond to a
standard rating.

Secondary at code max. of
125% or next standard size if
125% does not correspond to
a standard rating.

Secondary 600V or
Below

Secondary at code max. of
250% or next standard size if
250% does not correspond to
a standard rating.

Secondary at code max.
of 250%.

Secondary 600V or
Below

Secondary Over 600V

Secondary at code max.
of 225%.

Secondary at code max.
of 250%.

Secondary at code max.
of 250%.

Secondary Over 600V

Secondary 600V or
Below

Secondary Over 600V

(Note: Components on the secondary still need overcurrent protection.)

Rated primary current
less than 2 amps.

Transformer Impedance
Greater Than 6% But Less
Than 10%.

Primary at code max. of 300%
or next standard size if 300%
does not correspond to a
standard rating.

Transformer Impedance
Greater Than 6% But Less
Than 10%.

Transformer Impedance
Less Than or Equal to 6%.

Primary at code max.
of 300%

Transformer Impedance
Less Than or Equal to 6%.

Primary at code max. of
250% or next standard size
if 250% does not correspond
to a standard rating.
Primary at code max.
of 300%

(Note: Components on
the secondary still need
overcurrent protection.)

Primary
and
Secondary
Protection

Primary
Protection
Only

600V KRP-C_SP, LPJ_SP,
LPS-RK_SP, FNQ-R, FRS-R

Fuse
250V LPN-RK_SP, FRN-R

Fuse
2475V JCD
2750V JCX
2750/5500V JCW
5500V JCE, JCQ, JCY, JCU,
5.5 ABWNA, 5.5 AMWNA, 5.5 FFN
7200V 7.2 ABWNA, 7.2 SDLSJ, 7.2 SFLSJ
8300V JCZ, JDZ, 8.25 FFN
15500V JCN, JDN, JDM, 15.5 CAVH
17500V 17.5 CAV, 17.5 SDM
24000V 24 SDM, 24 SFM, 24 FFM
36000V 36 CAV, 36 SDQ, 36 SFQ
38000V 38 CAV
Secondary 600V or below
250V: LPN-RK_SP, FRN-R
600V: LPS-RK_SP, FRS-R
LPS-_SP, KRP-C_SP
FNQ-R_

Fuse Technology
Bussmann®

Solenoids
(Coils)

Solid State Devices
(Diodes, SCR-s,
Triacs, Transistors)

Mains
Feeders
Branches

Motor
Loads
(N.E.C. 430)

Based on 1996 N.E.C.®

Supplementary
Fuses

Branch Circuit
Fuses

Short-Circuit
Protection
Only

Main, Branch &
Feeder Circuits
(601-6000 Amps)

Feeder Circuits
(600 Amps & Less)

600V & Less

Above 600V

Motor
Loads

Size at 125% or next size larger.

Size at 125% or next size smaller.

0-500 FNQ ⁄Ω¡º-30

0-250V MDL ⁄Ω¡§-8, MDA ¤Ω¡º-20, FNM ⁄Ω¡º-10, FNW 12-30, MDQ ⁄Ω¡ºº-7

0-125V MDA 25-30, FNM 12-15

0-32V MDL 9-30, FNM 20-30

251-600V LPS-RK_SP, FRS-R
0-600V LPJ_SP, LP-CC

0-250V LPN-RK_SP, FRN-R

“F”, “S”, “K” & 170M Series fuses sized up to several sizes larger than full load RMS or DC rating of device.

150% to 225% of full load current of largest motor plus 100% of full load current of all other motors plus 125% of
continuous non-motor load plus 100% of non-continuous non-motor load.

*A max. of 175% (or the next standard size if 175% does not correspond to a standard size) is allowed for all but wound rotor and
all D.C. motors.

150%* of the F.L.A. of largest motor (if there are two or more motors of same size, one is considered to be the largest)
plus the sum of all the F.L.A. for all other motors.

150%* of the F.L.A. of largest motor (if there are two or more motors of same size, one is considered to be the largest)
plus the sum of all the F.L.A. for all other motors plus 100% of non-continuous, non-motor load plus 125% of
continuous, non-motor load.

Combination
Motor Loads
and other
Loads

*150% for wound rotor and all DC motors.

Max. of 300%* of motor F.L.A. or next size larger. If this will not allow motor to start due
to higher than normal inrush currents or longer than normal acceleration times (5 sec. or
greater), fuses through 600 amps may be sized up to 400% or next size smaller.

175%* of motor F.L.A. or next size larger. If this will not allow motor to start, due to higher
than normal inrush currents or longer than normal acceleration times (5 sec. or greater),
fuse may be sized up to 225% or next size smaller.

125% of motor F.L.A. or next size larger.

100% of non-continuous load plus 125% of continuous load.

Short-Circuit
Only

Short-Circuit
Only

Backup Overload
w/ Motor Starter
& Short-Circuit
Protection

No Motor
Load

Protected by NonTime-Delay Fuses
& all Class CC Fuses

Protected by
Time-Delay Fuses

FUSE SIZED FOR:

Compare the min. melting time-current characteristics
of the fuses with the time-current characteristics of the
overload relay curve. The size fuse which is selected
should be such that short-circuit protection is provided
by the fuse and overload protection is provided by the
controller overload relays.

0-130V FWA
0-250V FWX
0-500V FWH
0-600V FWC, KAC, KBC
0-700V FWP, 170M Series, SPP
0-1000V FWJ, 170M Series, SPJ

0-600V KRP-C_SP

0-250V LPN-RK_SP, FRN-R
251-600V LPS-RK_SP, FRS-R
0-600V LPJ_ SP, LP-CC

0-250V LPN-RK_SP, FRN-R
0-300V JJN
251-600V LPS-RK_SP, FRS-R
301-600V JJS
0-600V JKS, LPJ_SP, KTK-R, LP-CC, LPT

0-250V LPN-RK_SP, FRN-R
251-600V LPS-RK_SP, FRS-R
0-600V LPJ_SP
0-250V KTN-R, NON
0-300V JJN
251-600V KTS-R, NOS
301-600V JJS
0-600V LP-CC, LPT, JKS, KTK-R

0-250V LPN-RK_SP, FRN-R
251-600V LPS-RK_SP, FRS-R

Fuse
2400V JCK, JCK-A, JCH
4800V JCL, JCL-A, JCG
7200V JCR, 7.2 WKMSJ

Fuse Diagnostic Chart
Bussmann®

217

218

Capacitors
(N.E.C. 460)

Ballasts

Electric
Heat
(N.E.C. 424)

250% to 300%
of full load current

Protected by
Non-Time Delay
Fuses

Based on 1996 N.E.C.®

150% to 175%
of full load current

Protection recommended
as shown below, but not
required

Mercury,
Sodium, etc.

All Other
(Mercury,
Sodium, etc.)

Fluorescent

0-250V KTN-R, NON
0-300V JJN
251-600V KTS-R, NOS
0-600V JKS, KTK-R
301-600V JJS

Fuse
0-250V LPN-RK_SP, FRN-R
251-600V LPS-RK_SP, FRS-R
0-600V FNQ-R, LPJ_SP, LP-CC

Consult fixture manufacturer for size and type.

Consult fixture manufacturer for size and type.

Consult fixture manufacturer for size and type.

BAF
BAN
KTK
FNM
FNQ
FNW

HEB
HEX
HPC-D

HPF
HPS

HLR

GLR
GMF
GRF
BAF
BAN
KTK
FNM
FNQ
FNW

Holder

Fuse

Size at 125% or next size larger but in no case larger than 150 amperes for each subdivided load.

Size at 125% or next size larger but in no case larger than 60 amperes for each subdivided load.

Protected by
Time-Delay
Fuses

On load side of
motor running
overcurrent device

Outdoor

Indoor

Electric Boilers with
Resistance Type Immersion
Heating Elements in an ASME
Rated and Stamped Vessel.

Electric Space Heating

KTK-R
FNQ-R
LP-CC

KTQ
BBS

KTK-R
FNQ-R
LP-CC

GLQ
GMQ

Fuse

HEY

HPS-L
HPF-L

HPS-RR
HPF-RR

HLQ

Holder

Holder

HPF-EE
HPS-EE
HPF-JJ
SC 20
HPS-JJ
HPF-FF
SC 25-30
HPS-FF
SC -0-15

Fuse

Fuse
0-250V LPN-RK_SP, FRN-R, NON
0-300V JJN
0-480V SC
251-600V LPS-RK_SP, FRS-R, NOS
301-600V JJS
0-600V LPJ_SP, LP-CC, FNQ-R, JKS, KTK-R

Fuse Diagnostic Chart
Bussmann®

Time-Current & Current Limitation Curves

Bussmann®

TCF & TCFH CUBEFuseTM Fuses
TCF & TCFH Time-Current Characteristic Curves–
Average Melt

219

Bussmann®

Time-Current & Current Limitation Curves

KRP-C, Class L Fuses
KRP-C Current Limitation Curves

4000A
5000A
6000A

1600A
2000A
2500A
3000A

1200A

800A

KRP-C Time-Current Characteristic Curves—
Average Melt

AMPERE
RATING

300

1000,000

B
6,000A
5,000A
4,000A
3,000A
2,500A
2,000A
1,600A
1,200A
800A
601A

100

AMPERE
RATING

100,000

10

A

PROSPECITVE SHORT-CIRCUIT CURRENT
SYMMETRICAL RMS AMPERES

CURRENT IN AMPERES

220

200,000

100,000

1,000

.01

10,000

.1

300,000

100,000

1,000

10,000

1
1,000

TIME IN SECONDS

10,000

Bussmann®

Time-Current & Current Limitation Curves

LPN-RK (250V) Class RK1 Fuses

AMPERE
RATING

LPN-RK_SP (250V)

300

15/100
2/10
3/10
4/10 1/2
8/10 6/10
1
1-1/4
1-6/10
2
2-1/2
3-2/10
4
5
6-1/4
8
10
12

600A

400A

200A

100A

60A

30A

Time-Current Characteristic Curves—Average Melt

1/10

300

15A
20A

Time-Current Characteristic Curves—Average Melt

100

AMPERE
RATING
LPN-RK_SP (250V)

10

TIME IN SECONDS

TIME IN SECONDS

10

1

1

.1

1,000

100

1

.1

.01

10

.1

CURRENT IN AMPERES

Current Limitation Curves
B

400,000

AMPERE
RATING

LPN-RK_SP (250V)

100,000

600
400
200
100
60

10,000

30

200,000

100,000

1,000

10,000

A

1,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

RMS SYMMETRICAL CURRENT IN AMPERES

10,000

1,000

100

20

.01

RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

221

Bussmann®

Time-Current & Current Limitation Curves

LPS-RK (600V) Class RK1 Fuses

AMPERE
RATING

300

4
5
8
10
12

LPS-RK
(600V)

6-1/4

15/100
2/10
3/10
4/10 1/2
6/10
8/10
1
1-1/4
1-6/10
2
2-1/2
3-2/10

Time-Current Characteristic Curves—Average Melt

1/10

600A

400A

200A

100A

60A

30A

300

20A

Time-Current Characteristic Curves—Average Melt

AMPERE RATING

100
100

10
TIME IN SECONDS

1

1

1,000

1

.1

.01

.1

100

.1

10

TIME IN SECONDS

10

RMS SYMMETRICAL CURRENT IN AMPERES

AMPERE
RATING

100,000

600
400
200
100
60

10,000

30

200,000

100,000

A

10,000

20,000

LPS-RK
(600V)

1,000

222

B

400,000

1,000

CURRENT IN AMPERES

10,000

1,000

100

30

.01

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

Current Limitation Curves

Bussmann®

Time-Current & Current Limitation Curves

FRN-R (250V) Class RK5 Fuses

AMPERE
RATING

300

FRN-R
(250V)

15/100
2/10
3/10
4/10 1/2
8/10 6/10
1
1-1/4
1-6/10
2
2-1/2
3-2/10
4
5
6-1/4
8
10
12

Time-Current Characteristic Curves—Average Melt

1/10

600A

400A

200A

100A

60A

30A

300

15A

Time-Current Characteristic Curves—Average Melt

AMPERE
RATING
FRN-R (250V)

100

100

10
TIME IN SECONDS

TIME IN SECONDS

10

1

1

.1

1,000

100

1

.1

.01

10

.1

CURRENT IN AMPERES

AMPERE
RATING

FRN-R (250V)
100,000

600
400
200
100
60
10,000

30

100,000

10,000

1,000

1,000

A

200,000

20,000

B

400,000
INSTANTANEOUS PEAK LET-THRU CURRENT AMPERES

CURRENT IN AMPERES

10,000

1,000

20

100

Current Limitation Curves
.01

PROSPECTIVE SHORT CIRCUIT CURRENT
SYMMETRICAL RMS AMPERES

223

Bussmann®

Time-Current & Current Limitation Curves

FRS-R (600V) Class RK5 Fuses
Time-Current Characteristic Curves—Average Melt

300

1/10
15/100
2/10
3/10
4/10 1/2
6/10
8/10
1
1-1/4
1-6/10
2
2-1/2
3-2/10
4
5
6-1/4
8
10
12

Time-Current Characteristic Curves—Average Melt

AMPERE
RATING
FRS-R
(600V)

100

TIME IN SECONDS

10

1

1,000

100

1

.1

.01

10

.1

CURRENT IN AMPERES

Current Limitation Curves
B

AMPERE
RATING

FRS-R (600V)

100,000

600
400
200
100
60
30

10,000

PROSPECTIVE SHORT CIRCUIT CURRENT
SYMMETRICAL RMS AMPERES

224

200,000

100,000

1,000

10,000

A

1,000

INSTANTANEOUS PEAK LET THRU CURRENT AMPERES

400,000

Bussmann®

Time-Current & Current Limitation Curves

KTN-R (250V) Class RK1 Fuses
Current Limitation Curves

10

1

AMPERE
RATING

100

KTN-R
(250V)
100,000

600
400
200
100
10,000

60
30

A

1,000

100,000

KTN-R
(250V)

10,000

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

300

TIME IN SECONDS

B

400,000

200,000

AMPERE
RATING

1,000

600A

400A

200A

100A

60A

30A

Time-Current Characteristic Curves—Average Melt

RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

.1

10,000

1,000

100

40

.01

RMS SYMMETRICAL CURRENT IN AMPERES

225

Bussmann®

Time-Current & Current Limitation Curves

KTS-R (600V) Class RK1 Fuses

AMPERE
RATING
600
400
200
100

10,000

60
30

A

1,000

200,000

1

100,000

100,000

TIME IN SECONDS

10

KTS-R
(600V)

10,000

100

B

400,000

1,000

200

Current Limitation Curves

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

CURRENT IN
AMPERES

25
30

15

6
8
10

1

300

3

Time-Current Characteristic Curves—Average Melt

RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

CURRENT IN AMPERES

226

200

100

20

10

2

1

.01

300
400
500
600
700

.1

Bussmann®

Time-Current & Current Limitation Curves

LPJ (600V), Class J Fuses

.1

AMPERE
RATING

A
100

200,000

1

1,000

100,000

TIME IN SECONDS

10

10,000

10,000

100

600A
400A
200A
100A
60A
50A
40A
30A
20A
15A

LPJ

1,000

LPJ

B

100,000

100

AMPERE
RATING

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

600A

Current Limitation Curves

10A
15A
20A
30A
40A
50A
60A
100A
125A
200A
225A
400A

5A

3A

300

1A

Time-Current Characteristic Curves—
Average Melt

10,000

1,000

100

1

.01

10

PROSPECTIVE SHORT-CIRCUIT CURRENT
SYMMETRICAL RMS AMPS

RMS SYMMETRICAL CURRENT IN AMPERES

227

Bussmann®

Time-Current & Current Limitation Curves

JJN & JJS, Class T Fuses
400A
500A
800A

200A

100A

60A

15A
30A

10A

1A

AMPERE
RATING

5A

Time-Current Characteristic Curves—Average Melt
3A

600A

400A

200A

100A

60A

30A

300

15A

Time-Current Characteristic Curves—Average Melt

AMPERE
RATING

300
JJN
(300V)

JJS
(600V)

100

100

TIME IN SECONDS

10

1

.1

1,000

1

10

.01

10,000

1

100

TIME IN SECONDS

10

CURRENT IN AMPERES

1,000

20

100

.01

10,000

.1

RMS SYMMETRICAL CURRENT IN AMPERES

Current Limitation Curves

60
30
15

100,000

200,000

10,000

A
200

1,000

1,000

RMS SYMMETRICAL CURRENTS IN AMPERES
A-B = ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS)

228

AMPERE
RATING
400
200
100
60
30

10,000

1,000

A
200

200,000

10,000

1200
800
600

100,000

400
200
100

100,000

10,000

1200
800
600

JJS
(600V)

1,000

100,000

B

400,000

100

AMPERE
RATING

JJN
(300V)

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

B

400,000

100

INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS

Current Limitation Curves

RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)

Bussmann®

Time-Current & Current Limitation Curves

LP-CC & FNQ-R Class CC Fuses
FNQ-R-5

FNQ-R-7-1/2

FNQ-R-3

AMPERE
RATING

200

FNQ-R-1

Time-Current Characteristic Curves—Average Melt
FNQ-R-1/2

20
25
30

3
3⁄Ω™
4
4⁄Ω™
6
8
10
12
15

⁄Ω™
flꭧ
°Ω¡º
1
1⁄Ω¢

Time-Current Characteristic Curves—Average Melt

AMPERE
RATING

100

LP-CC

100

10

TIME IN SECONDS

1

200

300
400
500

100

10

1

0.01
.08

1000

CURRENT IN AMPERES

100

10

1

.01

1

.01

.1

.4

TIME IN SECONDS

10

CURRENT IN AMPERES

229

Time-Current & Current Limitation Curves

KTK-R, Class CC Fuses

8A
10A
15A
20A
30A

5A

3A

2A

1A

Time-Current Characteristic Curves—Average Melt

AMPERE
RATING

300

KTK-R

100

TIME IN SECONDS

10

1

RMS SYMMETRICAL CURRENT IN AMPERES

230

400

100

1

.01

10

.1

Bussmann®

Bussmann®

Glossary of Terms

Ampere
The measurement of intensity of rate of flow of
electrons in an electric circuit. An ampere is
the amount of current that will flow through a
resistance of one ohm under a pressure of one
volt.
Ampere Rating
The current-carrying capacity of a fuse. When
a fuse is subjected to a current above its
ampere rating, it will open the circuit after a
predetermined period of time.
Ampere Squared Seconds, l2t
The measure of heat energy developed within
a circuit during the fuse’s clearing. It can be
expressed as “melting l2t”, “arcing l2t” or the
sum of them as “Clearing l2t”. “l” stands for
effective let-through current (RMS), which is
squared, and “t” stands for time of opening, in
seconds.
Arcing Time
The amount of time from the instant the fuse
link has melted until the overcurrent is interrupted, or cleared.
Breaking Capacity
(See Interrupting Rating)
Cartridge Fuse
A fuse consisting of a current responsive element inside a fuse tube with terminals on both
ends.
Class CC Fuses
600V, 200,000A interrupting rating, branch
circuit fuses with overall dimensions of ⁄‹Ω£™∑ ≈
1⁄Ω™∑. Their design incorporates a rejection
feature that allows them to be inserted into
rejection fuse holders and fuse blocks that
reject all lower voltage, lower interrupting rating ⁄‹Ω£™∑ ≈ 1⁄Ω™∑ fuses. They are available from
⁄Ω¡ºA through 30A.
Class G Fuses
480V, 100,000A interrupting rating branch circuit fuses that are size rejecting to eliminate
overfusing. The fuse diameter is ⁄‹Ω£™∑ while
the length varies from 1fiΩ¡§∑ to 2⁄Ω¢∑. These are
available in ratings from 1A through 60A.
Class H Fuses
250V and 600V, 10,000A interrupting rating
branch circuit fuses that may be renewable or
non-renewable. These are available in ampere
ratings of 1 amp through 600A.
Class J Fuses
These fuses are rated to interrupt a minimum
of 200,000A ac. They are labelled
as “Current-Limiting”, are rated for 600vac,
and are not interchangeable with other classes.

Class K Fuses
These are fuses listed as K-1, K-5, or K-9
fuses. Each subclass has designated I2t and lp
maximums. These are dimensionally the same
as Class H fuses, and they can have interrupting ratings of 50,000, 100,000, or 200,000 A.
These fuses are current-limiting. However,
they are not marked “current-limiting” on their
label since they do not have a rejection feature.
Class L Fuses
These fuses are rated for 601 through 6000A,
and are rated to interrupt a minimum of
200,000A ac. They are labelled “CurrentLimiting” and are rated for 600Vac. They are
intended to be bolted into their mountings and
are not normally used in clips. Some Class L
fuses have designed in time-delay features for all
purpose use.
Class R Fuses
These are high performance fuses rated ⁄Ω¡º600A in 250V and 600V ratings. All are
marked “Current Limiting” on their label
and all have a minimum of 200,000A interrupting rating. They have identical outline
dimensions with the Class H fuses but have a
rejection feature which prevents the user from
mounting a fuse of lesser capabilities (lower
interrupting capacity) when used with special
Class R Clips. Class R fuses will fit into either
rejection or non-rejection clips.
Class T Fuses
An industry class of fuses in 300V and 600V
ratings from 1 amp through 1200A. They are
physically very small and can be applied
where space is at a premium. They are fast
acting and time-lag fuses, with an interrupting
rating of 200,000A RMS.
Classes of Fuses
The industry has developed basic physical
specifications and electrical performance
requirements for fuses with voltage ratings of
600V or less. These are known as standards.
If a type of fuse meets the requirements of a
standard, it can fall into that class. Typical
classes are K, RK1, RK5, G, L, H, T, CC, and J.
Clearing Time
The total time between the beginning of the
overcurrent and the final opening of the circuit
at rated voltage by an overcurrent protective
device. Clearing time is the total of the melting time and the arcing time.
Current Limitation
A fuse operation relating to short circuits only.
When a fuse operates in its current-limiting
range, it will clear a short circuit in less than ⁄Ω™
cycle. Also, it will limit the instantaneous peak
let-through current to a value substantially
less than that obtainable in the same circuit if
that fuse were replaced with a solid conductor of equal impedance.

Dual Element Fuse
Fuse with a special design that utilizes two
individual elements in series inside the fuse
tube. One element, the spring actuated trigger assembly, operates on overloads up to
5-6 times the fuse current rating. The other
element, the short circuit section, operates on
short circuits up to their interrupting rating.
Electrical Load
That part of the electrical system which actually uses the energy or does the work
required.
Fast Acting Fuse
A fuse which opens on overload and short
circuits very quickly. This type of fuse is not
designed to withstand temporary overload
currents associated with some electrical
loads.
Fuse
An overcurrent protective device with a fusible
link that operates and opens the circuit on an
overcurrent condition.
High Speed Fuses
Fuses with no intentional time-delay in the
overload range and designed to open as
quickly as possible in the short-circuit range.
These fuses are often used to protect solidstate devices.
Inductive Load
An electrical load which pulls a large amount
of current—an inrush current—when first
energized. After a few cycles or seconds the
current “settles down” to the full-load running
current.
Interrupting Capacity
See Interrupting Rating
Interrupting Rating
(Breaking Capacity)
The rating which defines a fuse’s ability to
safely interrupt and clear short circuits. This
rating is much greater than the ampere rating
of a fuse. The NEC® defines Interrupting
Rating as “The highest current at rated voltage that an overcurrent protective device is
intended to interrupt under standard test
conditions.”
Melting Time
The amount of time required to melt the fuse
link during a specified overcurrent. (See
Arcing Time and Clearing Time.)
“NEC” Dimensions
These are dimensions once referenced in the
National Electrical Code. They are common to
Class H and K fuses and provide interchangeability between manufacturers for
fuses and fusible equipment of given ampere
and voltage ratings.
Ohm
The unit of measure for electric resistance. An
ohm is the amount of resistance that will allow
one ampere to flow under a pressure of one
volt.

231

Bussmann®

Glossary of Terms

Ohm’s Law
The relationship between voltage, current,
and resistance, expressed by the equation E
= IR, where E is the voltage in volts, I is the
current in amperes, and R is the resistance in
ohms.
One Time Fuses
Generic term used to describe a Class H
nonrenewable cartridge fuse, with a single
element.
Overcurrent
A condition which exists on an electrical
circuit when the normal load current is
exceeded. Overcurrents take on two separate
characteristics—overloads and short circuits.
Overload
Can be classified as an overcurrent which
exceeds the normal full load current of a circuit.
Also characteristic of this type of overcurrent is
that it does not leave the normal current carrying path of the circuit—that is, it flows from
the source, through the conductors, through
the load, back through the conductors, to the
source again.
Peak Let-Through Current, lp
The instantaneous value of peak current letthrough by a current-limiting fuse, when it
operates in its current-limiting range.
Renewable Fuse (600V & below)
A fuse in which the element, typically a zinc
link, may be replaced after the fuse has
opened, and then reused. Renewable fuses
are made to Class H standards.
Resistive Load
An electrical load which is characteristic of
not having any significant inrush current.
When a resistive load is energized, the current
rises instantly to its steady-state value, without first rising to a higher value.

232

R.M.S. Current
The R.M.S. (root-mean-square) value of any
periodic current is equal to the value of the
direct current which, flowing through a resistance, produces the same heating effect in
the resistance as the periodic current does.
Semiconductor Fuses
Fuses used to protect solid-state devices.
See “High Speed Fuses”.
Short Circuit
Can be classified as an overcurrent which
exceeds the normal full load current of a circuit by a factor many times (tens, hundreds or
thousands greater). Also characteristic of this
type of overcurrent is that it leaves the normal
current carrying path of the circuit—it takes a
“short cut” around the load and back to the
source.
Short-Circuit Rating
The maximum short-circuit current an electrical component can sustain without the occurrence of excessive damage when protected
with an overcurrent protective device.
Short-Circuit Withstand Rating
Same definition as short-circuit rating.
Single Phasing
That condition which occurs when one phase
of a three phase system opens, either in a low
voltage (secondary) or high voltage (primary)
distribution system. Primary or secondary single phasing can be caused by any number of
events. This condition results in unbalanced
currents in polyphase motors and unless protective measures are taken, causes overheating and failure.

Threshold Current
The symmetrical RMS available current at the
threshold of the current-limiting range, where
the fuse becomes current-limiting when tested to the industry standard. This value can be
read off of a peak let-through chart where the
fuse curve intersects the A-B line. A threshold
ratio is the relationship of the threshold current to the fuse’s continuous current rating.
Time-Delay Fuse
A fuse with a built-in delay that allows temporary and harmless inrush currents to pass
without opening, but is so designed to open
on sustained overloads and short circuits.
Voltage Rating
The maximum open circuit voltage in which a
fuse can be used, yet safely interrupt an overcurrent. Exceeding the voltage rating of a fuse
impairs its ability to clear an overload or short
circuit safely.
Withstand Rating
The maximum current that an unprotected
electrical component can sustain for a specified period of time without the occurrence of
extensive damage.

Bussmann®

Index by Part Number
Catalog
Symbol

Page

AAO
196
ABC
34
ABCNA
170
ABFNA
170
ABGNA
170
ABWNA
170
AC
197
AD
197
ADLSJ
169
ADOSJ
169
AGA
32
AGC
34
AGU
36
AGW
32
AGX
32
AMWNA
170
ANL
38
ANN
38
ATC
40
ATM
40
BAF
24
BAN
24
BAO
196
BBS
23
BBU
157-158
BC
197
BC6031
64
BC6032
64
BC6033
64
BCCM
64
BD
197
BDAUX
112
BDH 101-102, 104, 109, 111, 114
BDNF
107, 111
BDS
102, 104, 105, 111
BDST
102
BDTA
103, 105
BDTL
103, 104, 105, 112
BDTS
112
BDZX
112
BG
64
BG3011
64
BG3012
64
BG3013
64
BG3021
64
BG3022
64
BG3023
64
BG3031
64
BG3032
64
BG3033
64
BH-0_ _ _
67, 130, 147
BH-1_ _ _
67, 130, 147
BH-2_ _ _
67, 130, 147
BH-3_ _ _
67, 130, 147
BM
64
BM6031
64
BM6032
64
BM6033
64
BNQ21-WH
93
BP/AGX
208
BP/GLH
208
BP/MAS
208
BP/XMAS
208
BQQ41-WH
93
C30F
199

Catalog
Symbol

Page

Catalog
Symbol

Page

C515
29
C517
29
C518
29
C519
29
C520
29
C5268
130, 150
C60F
199
CAV
170
CAVH
170
CD
197
CDAUX
103
CDBY
109
CDH 100, 102, 108, 110, 114
CDHX
101-102, 109, 111
CDHXB
104, 114
CDHXY
104, 114
CDHZX
110
CDMC
109
CDN
189
CDNF
106, 108, 110
CDS 100-101, 108-109, 186
CDSWM
109
CEO
196
CFC
103
CFD 99, 100, 101, 103, 102
CFTS
103
CFZ
103
CGL
190
CH
65
CIF06
191
CIF21
191
CIH
194
CIK
194
CIL
194
CJ
192
CM_ _CF
194
CS/XMAS
2048
CT
149
DD
197
DEO
196
DIN
132-138
DLN-R
14
DLS-R
14
ECL055
159
ECL155
160
ED
197
EDA
27
EET
149-150
EF
1937
EFC
113-116
EFJ
113-116
EFL
113-114, 116
EFS
197
EK
191
ENA
27
ENF
117-120
ERK-28
206
ESD
196
ET
149-150
FD
99, 104
FDM
209
FE
149-150
FEE
149-150
FF
197
FG
197

FL11H_ _
FL11K_ _
FL11T_ _
FM
FMM
FNA
FNM
FNQ
FNQ-R
FP
FR-1000
FRN-R
FRS-R
FSD
FT
FWA
FWC
FWH
FWJ
FWK
FWL
FWP
FWS
FWX
G
GBA
GBB
GDA
GDB
GDC
GF
GG
GH
GLD
GLQ
GLR
GMA
GMC
GMD
GMF
GMQ
GMT
GRF
H07C
H25_ _ _
H60_ _ _
HBH
HBV
HBW
HEB
HEC
HEG
HEH
HEJ
HET
HEX
HEY
HFA
HFB
HHB
HHC
HHD
HHF
HHG
HHL

173
173
173
149-150
149-150
37
25
25
22
202
205
12, 205
13, 205
209
202
124, 151
153
33, 126, 152
129, 155
154
155
128, 153-154
155
125, 152
64
37
35
30
30
30
197
197
197
37
39
39
31
31
31
39
39
186
39
194
47
48
70
70
70
80, 81
80
80
80
80
80
80
80
77
76
76
82
82
82
82
82

Catalog
Symbol
HHM
HHT
HHX
HJL
HK
HKL
HKP
HKR
HKT
HKU
HKX
HLD
HLQ
HLR
HLS
HLT
HM
HME
HMF
HMG
HMH
HMI
HMJ
HPC-D
HPD
HPF
HPG
HPM
HPS
HPS2
HR
HRC
HRE
HRF
HRG
HRH
HRI
HRJ
HRK
HTB
HTC-140M
HTC-15M
HTC-200M
HTC-210M
HTC-30M
HTC-35M
HTC-40M
HTC-45M
HTC-50M
HTC-55M
HTC-60M
HTC-65M
HTC-70M
HVA
HVB
HVJ
HVL
HVR
HVT
HVU
HVW
HVX
IBS
J-_ _
J60030

Page
87
77
82
75
75
75
72
75
75
75
75
75
39
39
186
186
77
77
77
77
77
77
77
79
78
78
78
79
78
79
77
195, 199
77
77
77
77
77
77
76
73, 74
85
85
85
85
71
71
71
69
69
71
69
69
71
171
171
171
171
171
171
171
171
171
150
203
53, 54

Catalog
Symbol
J60060
J60100
J60200
J60400
J60600
J70100
JCD
JCE
JCG
JCH
JCI
JCK
JCL
JCQ
JCR
JCT
JCU
JCW
JCX
JCY
JCZ
JDZ
JJN
JJS
JKS
JP60030
JT(N)60030
JT(N)60060
K
K07C
KAC
KAZ
KBC
KCA
KCB
KCC
KCD
KCE
KCF
KCH
KCJ
KCM
KCR
KCS
KCY
KCZ
KDA
KDB
KDC
KDD
KDE
KDF
KDH
KDJ
KDM
KDP
KDR
KDT
KDY
KEW
KEX
KFH-A
KFM
KFT
KFZ

Page
53,
53,
53,
53,
53,

54
54
54
54
54
56
166
166
161, 163
161, 162
166
162, 162
161, 162, 163
166
161, 163
166
168
166
167
167
168
168
19
19
18
55
57, 58
57, 58
28
194
127
38
127
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28
28

233

Bussmann®

Index by Part Number
Catalog
Symbol
KIG
KLM
KLU
KPF
KQO
KQT
KQV
KRP-CL
KRP-C_SP
KT3
KT4
KTK
KTK-R
KTN-R
KTQ
KTS-R
KTU
L09C
L14C
LBS
LCT
LET
LMMT
LMT
LP-CC
LPJ_SP
LPN-RK_SP
LPRK-28
LPS-RK_SP
M09C
M14C
MAX
MDA
MDL
MDQ
MIC
MIN
MIS
MMT
MT
MV055
MV155
N512
NC3
NDN
NDN1
NDN111
NDN3
NDN63
NDNA
NDNAS
NDNF1
NDNLFD1
NDNV4
NFT2
NFT3
NFTA
NH_G
NH_G-690
NH_M
NITD
NNB
NNB-R
NNC
No. 1

234

Page
28
24
8
28
28
28
28
7
6
92
92
24
22
15
23
15
8
195
195
201
148
148, 150
148, 150
148, 150
21
17
9
20
9
195
195
40
36
35
36
37
37
38
149
149
165
165
91
91
91
90
90
89
89
90, 103
91
94
94
89
91
91
91
200
200
200
196
203
203
203
2004

Catalog
Symbol

Page

Catalog
Symbol

No. 140
No. 2
No. 200
No. 201
No. 205
No. 213
No. 216
No. 220
No. 226
No. 242
No. 2621
No. 263
No. 2641
No. 2642
No. 2661
No. 2662
No. 2664
No. 270
No. 2880
No. 36
No. 4
No. 5
No. 6
No. 626
No. 7
No. 8
No.15
NON
NOS
NRA
NSD
NSE3
NSS3
NTN-R
NTQ23-WH
NTS-R
NZ_ _ _
OEFMA
OEGMA
OHFMA
OHGMA
OLGMA
OPM-1038
OPM-NG-SC3
OPM-NG-SM3
OPM-SW
OPMRH
OSD
P09C
P11C
PCT
PFD-948
PLK3
PLU1
PLU3
PMP
PON
PS
PSU1
R11C
R25030
R25060
R25100
R25200
R25400

207
204
208
208
208
203
203
207
203
203
203
203
203
203
203
203
203
207
208
206
204
204
204
203
204
204
205
16
16
91
196
91
91
203
94
203
198
172
172
172
172
172
44
41, 42
41, 42
45
109
196
195
195
187
205
92
92
92
122
189
122
92
195
48, 49
48, 49
48, 49
48, 49
48, 49

R25600
R60030
R60060
R60100
R60200
R60400
R60600
S
S-8001
SA
SAMI
SB
SC
SCY
SDLSJ
SDMSJ
SDQSJ
SFC
SFLSJ
SFMSJ
SFQSJ
SKA
SKLSJ
SKMSJ
SL
SOA72
SOU
SOW
SOX
SOY
SOY-B
SRU
SRW
SRX
SRY
SSD
SSU
SSW
SSX
SSY
SSY-L
SSY-RL
STD
STY
T
T30030
T30060
T30100
T30200
T60030
T60060
T60100
T60200
T60400
T60600
TB
TCF
TCFH
TDC10
TDC11
TDC180
TDC600
TL
TP158HC
TP15900-4

47,
47,
47,
47,
47,

Page
47,
50,
50,
50,
50,
50,
50,

48,
51,
51,
51,
51,
51,
51,

49
52
52
52
52
52
52
26
83
27
46
201
20
68
169
169
169
202
169
169
169
68
169
169
26
91
68
68
68
68
68
68
68
68
68
196
68
68
68
68
68
68
196
68
26
59, 60
59, 60
59, 60
59, 60
61, 62
61, 62
61, 62
61, 62
61, 62
61, 62
1201
4
4
34
35
33
33
26
180
178

Catalog
Symbol
TP15914
TPA
TPA-B
TPC &TPCDS
TPHCS
TPL
TPC &TPCDS
TPN
TPS
TPSFH
TYPE D (_D_ _)
VFNHA
VKNHA
VLB
W
WDFHO
WDLSJ
WDOH6
WDOSJ
WER
WFFHO
WFLSJ
WFMSJ
WFNHO
WFOH6
WJON6
WKFHO
WKLSJ
WKMSJ
WKNHO
11 Type
11239
11240
11241
11242
11675
11725
14002
14004
15087
15100
15149
15200
15800
160_ _ _
162_ _ _
163_ _ _
165_ _ _
170H_ _ _ _
170M_ _ _ _
1A1119
1A1120
1A1907
1A3398
1A3399
1A3400
1A4533
1A4534
1A5018
1A5600
1A5601
1A5602
1BS
24 Type
2499

Page
177
178
178
175
182
183
176
184
179
202
198
164
164
201
26
164
164, 169
164
169
187
164
164, 169
164
164
164
164
164
169
164, 169
164
187
63
63
63
63
95
95
95
95
185
178
121
178
177
96
96
96, 97, 98
96, 97
146-147
132-145
86
86
86
86
85
87
86
86
85
87
85
85
147
187
83

Catalog
Symbol

Page

2601
2602
2604
2605
2607
2608
2610
2611
2960
2NZ01
3723
3742
3743
3828
3835
4393
4421
4515
4520
4528
4529
4530
4574
4NZ01
5591
5592
5672
5674
5681
5682
5956
5960
5TPH
6NZ01
64000
64200
64300
64400
64600
68000
68150
68200
68300
68400
68600
7 Type
70 Series
74 Type
75 Type
76 Type
8000
80 Type
81 Type

63
63
63
63
63
63
63
63
171
198
66
66
66
84
66
84
66
66
84
171
171
171
83
198
88
88
88
88
88
88
88
88
202
197
28
28
28
28
28
28
28
28
28
28
28
187
185
188
188
188
83
188
187

Printed with Recyclable Paper using Soy Ink

Bussmann

®

Worldwide Circuit Protection Solutions

HEADQUARTERS
Cooper Industries
Bussmann Division
P. O. Box 14460
St. Louis, Missouri 63178-4460, USA
Telephone: 636 394 2877
Fax: 800 544 2570
International: 636 527 1413
Email: fusebox@buss.com
COOPER BUSSMANN CHICAGO
175 Hansen Court
Wood Dale, IL 60191
Telephone: 630 422 2400
Fax: 630 422 2500
EUROPEAN HEADQUARTERS
Cooper (UK) Ltd.
Bussmann Division
Burton-on-the-Wolds
Leicestershire LE12 5th, England
Telephone: 44 1509 882737
Fax: 44 1509 882786
Email: info@bussmann.co.uk
BUSSMANN ASIA-PACIFIC
1 Jalan Kilang Timor
#06-01 Pacific Tech Centre
Singapore 159303
Republic of Singapore
Telephone: 65 278 6151
Fax: 65 278 3151
Email: bussmann@bussasiapac.com.sg
BUSSMANN AUSTRALIA
Block X
391 Park Road
PO Box 257
Regents Park, Sydney
NSW 2143, Australia
Telephone: 61 2 9743 8333
Fax: 61 2 9743 8070

BUSSMANN BRASIL
Bussmann do Brasil Ltda.
Rodovia Santos Dumont, Km 23
Cruz das Almas
Itu - Sao Paulo- 13 300-000
Brasil
Telephone: 55 11 7824 1856
Fax: 55 11 7824 1721
BUSSMANN DENMARK
5 Literbuen
DK-2740 Skovlunde
Copenhagen, Denmark
Telephone: 45 4485 0900
Fax: 45 4485 0901
Email: bussmann@bussmann.dk
BUSSMANN INDIA
2nd floor, Unit #5
White House
23-29, St. Marks Road
Bangalore — 560 001
India
Telephone: 91 80 227 0893
Fax: 91 80 224 0124
BUSSMANN MEXICO
Arrow-Hart, S.A. de C.V.
Poniente 148, No. 933
02300 Mexico, D.F. Mexico
Telephone: 52 5 587 0211
Fax: 52 5 567 4049
COOPER ELECTRONIC TECHNOLOGIES, INC.
6000 Park of Commerce Blvd
Boca Raton, Fl 33487
Tel: 561 241 7876
Fax: 561 241 9339
ENBRAY CONTACTORS
Cooper (UK) Limited
Unit 5C, Clay Flatts
Industrial Estate
Workington, Cumbria
CA14 3YD
United Kingdom
Tel : +44 0 1900 870088
Fax : +44 0 1900 870099

COOPER BUSSMANN • P.O. BOX 14460 • ST. LOUIS, MO 63178-4460 • (636) 394-2877
World Wide Web: www.bussmann.com
REORDER #1007

10-02-50M

CUBEFuse™
The World’s First
“Finger-Safe” Industrial Fuse.

Finger-Safe
Test Points

30-Amp Fuses
Plug Into 60-Amp
Fuseholders

Class J TimeDelay Electrical
Performance

Permanent “OpenFuse” Indication
•
•

•

Finger-Safe Fuse,
Fuseholder, and
Wire Ports (IP-20)

•

Dovetail Fuseholder
Design for Ganging 30Amp and 60-Amp Poles

•
•

•
•

•

Smaller Footprint
Than Class J and
Class CC
Wire Ports Can
Accept Dual Wires

REORDER #1007

Fuseholder
Mounted by 35mm
DIN Rail or by
Standard Hardware

©2002, Cooper Bussmann, Inc. • St. Louis, MO 63178 • 636-394-2877
www.bussmann.com
www.cubefuse.com

10-02-40M



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Page Count                      : 240
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:8e0272ab-49e3-4e71-8433-dda4e8b8e95b
Producer                        : Acrobat Distiller 4.05 for Macintosh
Modify Date                     : 2008:11:25 15:38:23-06:00
Create Date                     : 2002:11:19 09:11:24Z
Metadata Date                   : 2008:11:25 15:38:23-06:00
Document ID                     : uuid:ba7c6d2c-62ed-4c38-a8bf-88e29cbba000
Format                          : application/pdf
EXIF Metadata provided by EXIF.tools

Navigation menu