Product Detail Manual
2014-10-17
: Pdf 92152-Attachment 92152-Attachment Batch10 unilog
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
www.sylvania.com OCTRON® 800 XP® ECOLOGIC®3 EXtended Performance Fluorescent Lamps Key Features & Benefits • All OCTRON 800 XP lamps are members of the SYLVANIA ECOLOGIC3 family of lamps • Extend re-lamp cycles • Average rated life of 36,000 hours • Options • Compatible with QUICKTRONIC electronic, high frequency ballasts – Maintains 95% lumens at 8000 hrs. – Higher light levels – 94% at 9600 hrs., 93% at 12,000 hrs. – Use low-power ballast – Improved CRI – 85 – Available in 2700K, 3000K, 3500K, 4100K & 5000K – Use fewer fixtures – Use fewer lamps with high power ballast – 17W, 25W, 32W & 40W The SYLVANIA OCTRON 800 XP ECOLOGIC fluorescent lamps provide 20% longer life or more, higher initial and maintained lumens, improved color rendition and longer re-lamp periods compared to conventional T8 lamps. Because of their longer life, OSRAM SYLVANIA offers an improved system warranty with the use of OCTRON 800 XP ECOLOGIC lamps on our QUICKTRONIC® electronic ballasts. (See QUICK 60+® warranty on page 4.) OCTRON 800 XP ECOLOGIC lamps operate on the same ballasts as OCTRON T8 lamps. OCTRON lamps are designed to operate on instant start and programmed rapid start ballasts. These ballasts include standard, high and low power models thus offering the choice to maximize light output or energy savings. Application Information Applications Application Notes Office Schools Retail General Lighting 1. Lamps starting down to 0°F (dependent on ballast) 2. Operation below 50°F may affect lumen output or lamp operation. 3. For cold temperature applications, use in enclosed fixture or use tube guard to maximize lamp performance. 4. For rapid start operation, check with ballast manufacturer for ground plane requirement. 5. For maximum energy savings, operate on high efficiency electronic instant start ballast. 6. These lamps may help facilitate compliance with national energy codes such as ASHRAE/IES 90.1 or IECC and state energy codes such as California Title 24. For more information contact your local building inspection office. FL025R7 5/08 SYLVANIA OCTRON 800 XP ECOLOGIC3 fluorescent lamps are designed to satisfy the Federal Toxicity Characteristic Leaching Procedure (TCLP) criteria for classification as non-hazardous waste in most states.* ECOLOGIC3 represents a more comprehensive approach to sustainability encompassing high efficiency, long life and RoHS/TCLP compliance. *Regulations may vary. Check your local and state regulations. Product Offering LampType FO17/827XP/ECO3 FO17/830XP/ECO3 FO17/835XP/ECO3 FO17/841XP/ECO3 FO17/850XP/ECO3 FO25/827XP/ECO3 FO25/830XP/ECO3 FO25/835XP/ECO3 FO25/841XP/ECO3 FO25/850XP/ECO3 FO32/827XP/ECO3 FO32/830XP/ECO3 FO32/835XP/ECO3 FO32/841XP/ECO3 FO32/850XP/ECO3 FO40/830XP/ECO3 FO40/835XP/ECO3 FO40/841XP/ECO3 Initial Lumens 1375 1375 1375 1375 1375 2175 2175 2175 2175 2175 3000 3000 3000 3000 2850 3750 3750 3750 * Based on 3hrs/start on programmed rapid start ballast Average Rated Life (hrs)* 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 36,000 Specification Data Catalog # Type Project Comments Prepared by Date Ordering Information OCTRON 800 XP ECOLOGIC3 SERIES LINEAR T8 FLUORESCENT LAMPS, (85 CRI, MEDIUM BI-PIN BASE) Item Ordering Number Abbreviation Nominal Length (in) Average Rated Life Initial (Hours)* Lumens Mean Lumens @8000 hrs. Mean Lumens @14,400 hrs. Color Temp. CRI 21587 FO17/827XP/ECO3 24 36,000 1375 1305 1295 2700K 85 21785 FO17/830XP/ECO3 24 36,000 1375 1305 1295 3000K 85 21778 FO17/835XP/ECO3 24 36,000 1375 1305 1295 3500K 85 21907 FO17/841XP/ECO3 24 36,000 1375 1305 1295 4100K 85 22193 FO17/850XP/ECO3 24 36,000 1375 1305 1295 5000K 85 21586 FO25/827XP/ECO3 36 36,000 2175 2065 2045 2700K 85 21910 FO25/830XP/ECO3 36 36,000 2175 2065 2045 3000K 85 21776 FO25/835XP/ECO3 36 36,000 2175 2065 2045 3500K 85 21774 FO25/841XP/ECO3 36 36,000 2175 2065 2045 4100K 85 22194 FO25/850XP/ECO3 36 36,000 2175 2065 2045 5000K 85 22039 FO32/827XP/ECO3 48 36,000 3000 2850 2820 2700K 85 21759 FO32/830XP/ECO3 48 36,000 3000 2850 2820 3000K 85 21763 FO32/835XP/ECO3 48 36,000 3000 2850 2820 3500K 85 21767 FO32/841XP/ECO3 48 36,000 3000 2850 2820 4100K 85 22026 FO32/850XP/ECO3 48 36,000 2850 2710 2680 5000K 85 21912 FO40/830XP/ECO3 60 36,000 3750 3560 3525 3000K 85 21911 FO40/835XP/ECO3 60 36,000 3750 3560 3525 3500K 85 21916 FO40/841XP/ECO3 60 36,000 3750 3560 3525 4100K 85 * Based on 3 hours per start on rapid or programmed rapid start ballasts. At 12 hours per start, life is expected to be 42,000 hours. Average rated life on instant start ballasts is 24,000 hours at 3 hours per start and 36,000 hours at 12 hours per start. Ordering Guide FO 32 / Fluorescent Wattage: OCTRON 17, 25, 32 or 40 watts 835 XP 8=85 CRI 27=2700K, 30=3000K 35=3500K, 41=4100K 50=5000K EXtended Performance / ECO3 ECOLOGIC3 System Comparison Lamp Type Lamp Lumens # Lamps Ballast System Watts @ 277V System Lumens System Lumens @8000 hrs Relative Lumens % Energy Savings FO32/700/ECO 2800 3 QHE3x32ISN 82 7560 6800 100% – FO32/800/ECO 2950 3 QHE3x32ISN 82 7965 7330 108% 0% FO32/800XP/ECO3 3000 3 QHE3x32ISN 82 8100 7695 113% 0% FO32/800XP/ECO3 3000 3 QHE3x32ISL 71 7020 6585 97% 13% FO32/800XP/ECO3 3000 3 QHE3x32ISH 109 10,620 10,090 148% -33% FO32/800XP/ECO3 3000 2 QHE2x32ISH 73 7200 6840 101% 11% Technical Information Dimensions Lamp Type FO17 FO25 FO32 FO40 (A) Max. Overall Length (in.) 23.78 35.78 47.78 59.61 (B) Base Face to Opposite Pin (in.) Min. Max. 23.41 23.50 35.40 35.50 47.41 47.50 59.24 59.33 (C) Max. Base Face to Base Face (in.) 23.22 35.22 47.22 59.05 A B C (D) Max. Outside Diameter (in.) 1.1 1.1 1.1 1.1 D Lumen Maintenance OCTRON XP, OCTRON & F40/CW Typical Fluorescent Lamp Mortality 100 90 80 PERCENT SURVIVING 70 60 50 40 30 20 10 0 0 20 40 60 80 100 120 PERCENT RATED LIFE 140 160 180 200 Sample Specification Lamp(s) shall be OCTRON 800XP ECOLOGIC3 lamp(s) (FO32/800XP/ECO3, FO17/800XP/ECO3, FO25/800XP/ECO3 or FO40/800XP/ECO3) having medium bi-pin bases. Lamp(s) shall be designed to pass the existing Federal TCLP test in force at time of manufacture. Lamp(s) shall have an average rated life of 36,000 hours, (3000, 1375, 2175, 3750) initial lumens, (2850, 1305, 2065, 3560) mean lumens at 8000 hours, a correlated color temperature of (2700K, 3000K, 3500K, 4100K or 5000K) and a CRI of 85. The OCTRON lamp(s) shall be operated on dedicated QUICKTRONIC ballasts with complete system warranty from the manufacturer covering lamp(s) and ballast(s). Warranty QUICK 60+ warranty for OSRAM SYLVANIA lamp and ballast combination Limited 36 month lamp warranty and a five year ballast warranty is possible if both lamps and ballasts are provided by OSRAM SYLVANIA. See the QUICK 60+ warranty for details and restrictions. OSRAM SYLVANIA National Customer Service and Sales Center 18725 N. Union Street Westfield, IN 46074 USA OEM/Special Markets Phone: 1-800-762-7191 Fax: 1-800-762-7192 Display/Optic Phone: 1-888-677-2627 Fax: 1-800-762-7192 In Canada OSRAM SYLVANIA LTD Headquarters 2001 Drew Road Mississauga, ON L5S 1S4 Industrial Commercial Phone: 1-800-263-2852 Fax: 1-800-667-6772 Special Markets Phone: 1-800-265-2852 Fax: 1-800-667-6772 Visit our website: www.sylvania.com SYLVANIA, OCTRON, ECOLOGIC and QUICK 60+ are registered trademarks and XP is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH, Germany, used under license. © 2008 OSRAM SYLVANIA 5/08 National Accounts Phone: 1-800-562-4671 Fax: 1-800-562-4674 Photography Industrial Commercial Phone: 1-800-255-5042 Fax: 1-800-255-5043
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1.1-111 Instance ID : uuid:256982b2-16e4-11dd-a72b-000a95a6e7d2 Document ID : adobe:docid:indd:a7eae396-137b-11dd-86ce-9cf74d56ccd3 Rendition Class : proof:pdf Derived From Instance ID : 007cb4ec-11f1-11dd-80f0-8bb9dfc7bdef Derived From Document ID : adobe:docid:indd:91bdde49-e7a6-11dc-b415-cf16d1ce3c36 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 450.00, 72.00, 72.00 Manifest Placed Y Resolution : 450.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches Manifest Reference Instance ID : uuid:b9a390df-ba84-11da-b6bd-c924b6e065f2, uuid:308A3E1E831811DCBB30E4453606C7E2, uuid:D07E03495D3911DB8C44B747C2E077AE Manifest Reference Document ID : adobe:docid:photoshop:9462a01a-b503-11da-8f9a-c27b962c2c5d, uuid:308A3E1D831811DCBB30E4453606C7E2, uuid:D07E03485D3911DB8C44B747C2E077AE Create Date : 2008:04:30 14:34:58-04:00 Modify Date : 2008:04:30 14:35:02-04:00 Metadata Date : 2008:04:30 14:35:02-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 13672 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Postscript Name : HelveticaNeue-Light, HelveticaNeue-LightCond, HelveticaNeue-Condensed, HelveticaNeue-MediumCond, HelveticaNeue-BoldCond, HelveticaNeue-Roman Profile Blob : , , , , , Page Count : 4 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools