94262 Catalog

2014-09-04

: Pdf 94262-Catalog 94262-Catalog 662019 Batch7 unilog

Open the PDF directly: View PDF PDF.
Page Count: 80

Download94262-Catalog
Open PDF In BrowserView PDF
Interface relays and optocouplers
Product group picture

5

5/1 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays and optocouplers
Table of contents
Interface Relays and Optocouplers
Pluggable interface relays	

5/3

Table of contents	

5/4

Benefits and advantages	

5/5

Approvals and marks	

5/6

Ordering details	

5/7

Technical data	

5/14

Technical data, Load limit curves	

5/16

Load limit curves	

5/17

Connection diagrams	

5/18

Interface relays and optocouplers R500 / R600 range	

5/21

Table of contents	

5/22

Benefits and advantages	

5/23

Type designators	

5/24

Interface relays and optocouplers R500 range	

5/25

Table of contents	

5/26

Interface relays R500 range	

5/27

Table of contents	

5/28

Selection	

5/29

Ordering details	

5/30

Technical information	

5/31

Optocouplers R500 range	

5/33

Table of contents	

5/34

Selection	

5/35

Ordering details	

5/36

Connection diagrams	

5/37

Technical data	

5/38

Interface relays and optocouplers R600 range	

5/45

Table of contents	

5/46

Interface relays R600 range	

5/47

Table of contents	

5/48

Benefits and advantages	

5/49

Selection	

5/51

Ordering details	

5/53

Connection diagrams	

5/55

Technical data	

5/56

General technical data	

5/61

Dimensional drawings, Load limit curves	

5/62

Optocouplers R600 range	

5/63

Table of contents	

5/64

Selection	

5/65

Ordering details	

5/67

Connection diagrams	

5/68

Technical data	

5/69

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/2

5

Pluggable interface relays
Product group picture

5

5/3 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Pluggable interface relays
Table of contents
Pluggable interface relays
Product group picture	

5/3

Table of contents	

5/4

Benefits and advantages	

5/5

Approvals and marks	

5/6

Ordering details	

5/7

Technical data	

5/14

Technical data, Load limit curves	

5/16

Load limit curves	

5/17

Connection diagrams	

5/18

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/4

Pluggable interface relays
Benefits and advantages
Pluggable pcb relays CR-P

Pluggable miniature relays CR-M

Pluggable universal relays CR-U

	 9 different coil voltages
	 DC versions:
		 12 V, 24 V, 48 V, 110 V
	 AC versions:
		 24 V, 48 V, 110 V, 120 V, 230 V

	 12 different coil voltages
	 DC versions:
		 12 V, 24 V, 48 V, 60 V,
		 110 V, 125 V, 220 V
	 AC versions:
		 24 V, 48 V, 110 V, 120 V, 230 V

	 12 different coil voltages
	 DC versions:
		 12 V, 24 V, 48 V, 110 V, 125 V, 220 V
	 AC versions:
		 24 V, 48 V, 60 V, 110 V, 120 V, 230 V

	 Output contacts:
	 1 c/o contact (16 A) or
	 2 c/o contacts (8 A)
		 optionally equipped with
		gold contacts

	 Output contacts
	 2 c/o contacts (12 A) or
	 3 c/o contacts (10 A) or
	 4 c/o contacts (6 A)
		 optionally equipped with
		 gold contacts, LED and free
		wheeling diode

	 Logical or standard sockets
	 Cadmium-free contact material
	 Width of socket: 15,5 mm

5

	 Integrated test button for manual
actuation and locking of the output
contacts (blue = DC, orange = AC) that
can be removed if necessary

	 Integrated test button for manual
actuation and locking of the output
contacts (blue = DC, orange = AC) that can
be removed if necessary

	 Pluggable function modules
	 Reverse polarity protection/
		 Free wheeling diode
	 LED indication
	 RC elements
	 Overvoltage protection

	 Output contacts
	 2 c/o contacts (10 A) or
	 3 c/o contacts (10 A)

	 With or without integrated LED
	 Logical or standard sockets
	 Cadmium-free contact material
	 Width on socket: 27 mm
	 Pluggable function modules
	 Reverse polarity protection/
		 Free wheeling diode
	 LED indication
	 RC elements
	 Overvoltage protection

	 With or without integrated LED
	 Cadmium-free contact material
	 Width on socket: 38 mm
	 Pluggable function modules
	 Reverse polarity protection/
		 Free wheeling diode
	 LED indication
	 RC elements
	 Overvoltage protection
	 Multifunction time module

1

1

1

2

2

2

3

3

3

4

4
4
4

1 	Socket

1 	Socket

1 	Socket

2 	 Pluggable function module

2 	 Pluggable function module

2 	 Pluggable function module

3 	 Interface relay

3 	 Interface relay

3 	 Interface relay

4 	Holder

4 	Holder

4 	Holder

4 	 Marker label

5/5 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Pluggable interface relays
Approvals and marks
Kinds of sockets

Kind of connecting terminals

Standard sockets - Position of connecting terminals:
Coil connection (A1-A2) on lower socket side,
contact connections (n/o and n/c contacts)
on the lower and upper socket side.
Logical sockets - Position of connecting terminals:
Coil connection (A1-A2) on lower socket side,
all contact connections (common contacts,
n/o and n/c contacts) on upper socket side.

Screw type

Spring type

Fork type

Details see connection diagrams

5
Approvals and marks
J	existing
j	pending

CR-M..L..
CR-M..SS

CR-M..SF

CR-U..S
CR-U..E

CR-U..SM

CR-P/M

CR-U

J

J

J

J 6)

J 7)

J

J

J

J

J

J

J

J

J 8)

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

CR-U

J

CR-M

J

CR-P

J

UL 508

J

J 1)

J

cG

CAN/CSA C22.2 No.14

J

J

2)

J

3)

J

Approvals
G

F

CAN/CSA C22.2 No.14

J

J

J

VDE

J

J 4)

J

J

D

GOST

P

Lloyds Register

E

CCC

J

L

RMRS

J

CE

J

J

J

J 5)

J

J

J

J

8)

Modules

CR-PLC

Sockets
CR-PLS
CR-PSS

Relays

Marks
a

1)
2)
3)
4)
5)
6)
7)
8)

J

except 60 V DC and 125 V DC devices with gold contacts
except devices with gold contacts
except 60 V DC and 125 V DC devices
except 125 V DC devices
only devices with 4 c/o contacts
except CR-P/M 42B, CR-P/M 42BV, CR-P/M 42C, CR-P/M 42CV, CR-P/M 52D, CR-P/M 62E, CR-P/M 62EV, CR-P/M 62D, CR-P/M 62DV
except CR-U 41B, CR-U 41BV, CR-U 41C, CR-U 41CV, CR-U 51D, CR-U 61CV, CR-U 61E, CR-U 61EV, CR-U 61D, CR-U 61DV, CR-U 91C, CR-U T
except 60 V and 125 V devices

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/6

2CDC 291 045 F0004

Pluggable interface relays
Ordering details

CR-P

Description
Interface relays are widely used in various industrial applications:
As an interface they link the electronic controlling, e.g. PLC (programmable logic controller),
PC or field bus systems, to the sensor / actuator level. Here, they take on various functions:
Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching
voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal
protective circuits and thus are overload-proof against short-time variations like current or
voltage peaks.
Ordering details - CR-P range
Rated control
supply voltage

5

Outputs

Contact
ratings

Type

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

12 V DC
24 V DC

CR-P012DC1
CR-P024DC1

1SVR405600R4000
1SVR405600R1000

48 V DC

CR-P048DC1

1SVR405600R6000

110 V DC

CR-P110DC1

1SVR405600R8000

24 V AC
48 V AC

CR-P024AC1

1SVR405600R0000

CR-P048AC1

1SVR405600R5000

CR-P110AC1
CR-P120AC1
CR-P230AC1

1SVR405600R7000
1SVR405600R2000
1SVR405600R3000

12 V DC
24 V DC

CR-P012DC2

1SVR405601R4000

CR-P024DC2

1SVR405601R1000

48 V DC

CR-P048DC2

1SVR405601R6000

110 V DC

CR-P110DC2

1SVR405601R8000

CR-P024AC2
CR-P048AC2
CR-P110AC2

1SVR405601R0000
1SVR405601R5000
1SVR405601R7000

120 V AC

CR-P120AC2

1SVR405601R2000

230 V AC

CR-P230AC2

1SVR405601R3000

24 V DC

CR-P024DC2

1SVR405606R1000

CR-P024AC2G

1SVR405606R0000

CR-P110AC2G

1SVR405606R7000

CR-P230AC2G

1SVR405606R3000

1 c/o (SPDT)

250 V, 16 A

110 V AC
120 V AC
230 V AC

24 V AC
48 V AC
110 V AC

24 V AC
110 V AC

2 c/o (SPDT)

2 c/o (SPDT)
gold contact

250 V, 8 A

250 V, 8 A

CR-PLS

2CDC 291 006 F0011

230 V AC

Version

10

0.014
(0.031)

10

0.014
(0.031)

Connection Type
terminal

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

Logical socket with protective
separation

2CDC 291 004 F0007

0.014
(0.031)

Ordering details - Accessories

screw

CR-PLS

1SVR405650R0000

screw

CR-PLSx

1SVR405650R0100

Logical socket

CR-PJ

10

Standard socket

0.045
(0.099)
10

0.043
(0.095)

spring

CR-PLC

1SVR405650R0200

0.042
(0.093)

screw

CR-PSS

1SVR405650R1000

0.038
(0.084)

CR-PH

1SVR405659R0000

Plastic holder for socket

10
Jumper bar for sockets with screw connection

CR-PJ

1SVR405658R5000

Marker

CR-PM

1SVR405658R0000

Bold printed products = stocked products

5/7 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

10

0.002
(0.004)
0.018
(0.040)
0.0002
(0.0004)

2CDC 291 046 F0004

Pluggable interface relays
Ordering details

CR-M

Description
Interface relays are widely used in various industrial applications:
As an interface they link the electronic controlling, e.g. PLC (programmable logic controller),
PC or field bus systems, to the sensor / actuator level. Here, they take on various functions:
Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching
voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal
protective circuits and thus are overload-proof against short-time variations like current or
voltage peaks.
Ordering details - CR-M range without LED
Rated control
supply voltage

Outputs

Contact
ratings

Type

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC

2 c/o (SPDT)

CR-M012DC2
CR-M024DC2
CR-M048DC2
CR-M060DC2
CR-M110DC2
CR-M125DC2
250 V, 12 A
CR-M220DC2

1SVR405611R4000
1SVR405611R1000
1SVR405611R6000
1SVR405611R4200
1SVR405611R8000
1SVR405611R8200
1SVR405611R9000

CR-M024AC2
CR-M048AC2
CR-M110AC2
CR-M120AC2
CR-M230AC2

1SVR405611R0000
1SVR405611R5000
1SVR405611R7000
1SVR405611R2000
1SVR405611R3000

CR-M012DC3
CR-M024DC3
CR-M048DC3
CR-M060DC3
CR-M110DC3
CR-M125DC3
250 V, 10 A CR-M220DC3

1SVR405612R4000
1SVR405612R1000
1SVR405612R6000
1SVR405612R4200
1SVR405612R8000
1SVR405612R8200
1SVR405612R9000

CR-M024AC3
CR-M048AC3
CR-M060AC3
CR-M110AC3
CR-M120AC3
CR-M230AC3

1SVR405612R0000
1SVR405612R5000
1SVR405612R5200
1SVR405612R7000
1SVR405612R2000
1SVR405612R3000

CR-M012DC4
CR-M024DC4
CR-M048DC4
CR-M060DC4
CR-M110DC4
CR-M125DC4
CR-M220DC4

1SVR405613R4000
1SVR405613R1000
1SVR405613R6000
1SVR405613R4200
1SVR405613R8000
1SVR405613R8200
1SVR405613R9000

CR-M024AC4
CR-M048AC4
CR-M110AC4
CR-M120AC4
CR-M230AC4

1SVR405613R0000
1SVR405613R5000
1SVR405613R7000
1SVR405613R2000
1SVR405613R3000

24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC

3 c/o (SPDT)

24 V AC
48 V AC
60 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC

4 c/o (SPDT)

24 V AC
48 V AC
110 V AC
120 V AC
230 V AC

250 V, 6 A

10

0.033
(0.073)

10

0.033
(0.073)

10

0.033
(0.073)

Bold printed products = stocked products

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/8

5

Pluggable interface relays
Ordering details
Ordering details - CR-M range

2CDC 291 046 F0004

Rated control
supply voltage

CR-M

Outputs

Contact
ratings

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

CR-M012DC2L
CR-M024DC2L
CR-M048DC2L
CR-M060DC2L
CR-M110DC2L
CR-M125DC2L
CR-M220DC2L

1SVR405611R4100
1SVR405611R1100
1SVR405611R6100
1SVR405611R4300
1SVR405611R8100
1SVR405611R8300
1SVR405611R9100

CR-M024AC2L
CR-M048AC2L
CR-M110AC2L
CR-M120AC2L
CR-M230AC2L

1SVR405611R0100
1SVR405611R5100
1SVR405611R7100
1SVR405611R2100
1SVR405611R3100

CR-M012DC3L
CR-M024DC3L
CR-M048DC3L
CR-M060DC3L
CR-M110DC3L
CR-M125DC3L
CR-M220DC3L

1SVR405612R4100
1SVR405612R1100
1SVR405612R6100
1SVR405612R4300
1SVR405612R8100
1SVR405612R8300
1SVR405612R9100

CR-M024AC3L
CR-M048AC3L
CR-M110AC3L
CR-M120AC3L
CR-M230AC3L

1SVR405612R0100
1SVR405612R5100
1SVR405612R7100
1SVR405612R2100
1SVR405612R3100

CR-M012DC4L
CR-M024DC4L
CR-M048DC4L
CR-M060DC4L
CR-M110DC4L
CR-M125DC4L
250 V, 6 A
CR-M220DC4L

1SVR405613R4100
1SVR405613R1100
1SVR405613R6100
1SVR405613R4300
1SVR405613R8100
1SVR405613R8300
1SVR405613R9100

CR-M024AC4L
CR-M048AC4L
CR-M110AC4L
CR-M120AC4L
CR-M230AC4L

1SVR405613R0100
1SVR405613R5100
1SVR405613R7100
1SVR405613R2100
1SVR405613R3100

12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC

2 c/o (SPDT)
with LED

250 V,
12 A

24 V AC
48 V AC

5

Type

110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC

3 c/o (SPDT)
with LED

250 V,
10 A

24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC
220 V DC

4 c/o (SPDT)
with LED

24 V AC
48 V AC
110 V AC
120 V AC
230 V AC2
24 V DC

4 c/o (SPDT),
LED and
free-wheeling
diode

250 V, 6 A CR-M024DC4LD

1SVR405614R1100

24 V DC

CR-M024DC4G

1SVR405618R1000

24 V AC

CR-M024AC4G
250 V, 6 A
CR-M110AC4G
CR-M230AC4G

1SVR405618R0000
1SVR405618R7000
1SVR405618R3000

110 V AC

4 c/o (SPDT),
gold contacts

230 V AC
Bold printed products = stocked products

5/9 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

10

0.033
(0.073)

10

0.033
(0.073)

10

0.033
(0.073)

10

0.033
(0.073)

10

0.033
(0.073)

Pluggable interface relays
Ordering details
Rated control
supply voltage

Outputs

Contact
ratings

Type

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

2CDC 291 046 F0004

12 V DC
24 V DC
48 V DC
60 V DC
110 V DC
125 V DC

CR-M

220 V DC
24 V AC

4 c/o (SPDT)
with gold
contacts and
LED

250 V /
6A

48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC

4 c/o (SPDT)
with gold
contacts,
LED and
free-wheeling
diode

CR-M012DC4LG
CR-M024DC4LG
CR-M048DC4LG
CR-M060DC4LG
CR-M110DC4LG
CR-M125DC4LG
CR-M220DC4LG

1SVR405618R4100
1SVR405618R1100
1SVR405618R6100
1SVR405618R4300
1SVR405618R8100
1SVR405618R8300
1SVR405618R9100

10

0.033
(0.073)

CR-M024AC4LG
CR-M048AC4LG
CR-M110AC4LG
CR-M120AC4LG
CR-M230AC4LG

1SVR405618R0100
1SVR405618R5100
1SVR405618R7100
1SVR405618R2100
1SVR405618R3100

10

0.033
(0.073)

CR-M012DC4LDG

1SVR405618R4400
10

CR-M024DC4LDG

1SVR405618R1400

0.033
(0.073)

Ordering details - Accessories

2CDC 291 009 F0011

Version

CR-M4SS

Connection Type
terminal

Price

Pkg Weight
(1 pce)
qty kg (lb)

Logical socket for 2 c/o

0.055
(0.121)

CR-M2LS

1SVR405651R1100

CR-M3LS

1SVR405651R2100

Logical socket for 2/4 c/o

CR-M4LS

1SVR405651R3100

0.066
(0.146)

Logical socket for 2 c/o

CR-M2LC

1SVR405651R1200

0.065
(0.143)

CR-M4LC

1SVR405651R3200

0.066
(0.146)

CR-M2SS

1SVR405651R1000

0.066
(0.146)

CR-M3SS

1SVR405651R2000

Standard socket for 2/4 c/o

CR-M4SS

1SVR405651R3000

0.070
(0.154)

Standard socket for 2 c/o

CR-M2SF

1SVR405651R1300

0.040
(0.088)

CR-M4SF

1SVR405651R3300

Plastic holder

CR-MH

1SVR405659R1000

10

0.003
(0.007)

Metal holder

CR-MH1

1SVR405659R1100

10

0.0005
(0.001)

Jumper bar for sockets with
screw connection

CR-MJ

1SVR405658R6000

10

0.029
(0.064)

Marker

CR-MM

1SVR405658R1000

10

0.0005
(0.001)

Logical socket for 3 c/o

screw

spring

Logical socket for 2/4 c/o
Standard socket for 2 c/o
Standard socket for 3 c/o
CR-MJ

Order code

screw

fork type

Standard socket for 2/4 c/o

10

10

10

10

0.062
(0.137)

0.068
(0.150)

0.048
(0.106)

Bold printed products = stocked products

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/10

5

Pluggable interface relays
Ordering details
Ordering details - CR-P/M range (all products stocked)
Rated control
supply voltage

Description

Version

Type

Order code

Price

Pkg Weight
(1 pce)

2CDC 291 005 S0011

qty kg (lb)

CR-P/M ...

6-220 V DC

6-24 V DC
24-60 V DC
110 V DC

6-24 V AC
24-60 V AC
110-230
V AC/DC

Diode and
LED - Reverse polarity
protection/
free wheeling
diode

Spark quenching

6-24 V AC/DC

24-60 V AC/DC

Diode, LED
and reverse
polarity
protection

110 V DC
110-230 V AC
6-24 V AC/DC

24-60 V AC/DC

Varistor and
LED
Overvoltage
protection

110 V DC
110-230 V AC
24 V AC
115 V AC
230 V AC

A1+, A2-

CR-P/M 22

1SVR405651R0000

10

0.003
(0.007)

10

0.003
(0.007)

10

0.003
(0.007)

10

0.003
(0.007)

10

0.003
(0.007)

10

0.002
(0.004)

CR-P/M 42
red, A1+, A2green, A1+, A2- CR-P/M 42V

1SVR405652R0000
1SVR405652R1000
CR-P/M 42B
red, A1+, A21SVR405652R4000
green, A1+, A2- CR-P/M 42BV 1SVR405652R4100
CR-P/M 42C
red, A1+, A21SVR405652R9000
green, A1+, A2- CR-P/M 42CV 1SVR405652R9100
CR-P/M 52B
1SVR405653R0000
CR-P/M 52D
1SVR405653R4000

red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2-

Overvoltage
protection

CR-P/M 52C

1SVR405653R1000

CR-P/M 62

1SVR405654R0000

CR-P/M 62V

1SVR405654R1000

CR-P/M 62E

1SVR405654R4000

CR-P/M 62EV

1SVR405654R4100

CR-P/M 92

1SVR405654R0100

CR-P/M 92V

1SVR405654R1100

CR-P/M 62C

1SVR405655R0000

CR-P/M 62CV

1SVR405655R1000

CR-P/M 62D

1SVR405655R4000

CR-P/M 62DV

1SVR405655R4100

CR-P/M 92C

1SVR405655R0100

CR-P/M 92CV

1SVR405655R1100

CR-P/M 72
CR-P/M 72A
CR-P/M 82

1SVR405656R0000
1SVR405656R1000
1SVR405656R2000

2CDC 292 014 F0005

CR-P/M 42,	
CR-P/M 42C,	
CR-P/M 42BV,	

CR-P/M 42B, 	
CR-P/M 42V, 	
CR-P/M 42CV

CR-P/M 62E,	
CR-P/M 62V, 	
CR-P/M 92V

CR-P/M 62C,	
CR-P/M 92C,	
CR-P/M 62DV	

CR-P/M 62D,	
CR-P/M 62CV,	
CR-P/M 92CV

CR-P/M 52B,	
CR-P/M 52D,

CR-P/M 52C

CR-P/M 72, 	
CR-P/M 72A,	

CR-P/M 82

2CDC 292 017 F0005

2CDC 292 018 F0005

2CDC 292 013 F0005

CR-P/M 22

CR-P/M 62,	
CR-P/M 92,	
CR-P/M 62EV,	

2CDC 292 015 F0005

Connection diagrams

2CDC 292 016 F0005

5

Diode Reverse
polarity
protection/
free wheeling
diode

5/11 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Pluggable interface relays
Ordering details

2CDC 291 047 F0004

Description
Interface relays are widely used in various industrial applications:
As an interface they link the electronic controlling, e.g. PLC (programmable logic controller),
PC or field bus systems, to the sensor / actuator level. Here, they take on various functions:
Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching
voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal
protective circuits and thus are overload-proof against short-time variations like current or
voltage peaks.

CR-U

Ordering details - CR-U range

2CDC 291 007 S0011

Rated control
supply voltage
12 V DC
24 V DC
48 V DC
110 V DC
220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
110 V DC
125 V DC
220 V DC
24 V AC
48 V AC
60 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
110 V DC
220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC
12 V DC
24 V DC
48 V DC
110 V DC
220 V DC
24 V AC
48 V AC
110 V AC
120 V AC
230 V AC

Outputs

Contact
ratings

2 c/o
without LED

250 V, 10 A

3 c/o
without LED

250 V, 10 A

2 c/o
with LED

250 V, 10 A

3 c/o
with LED

250 V, 10 A

Type

Order code

CR-U012DC2
CR-U024DC2
CR-U048DC2
CR-U110DC2
CR-U220DC2
CR-U024AC2
CR-U048AC2
CR-U110AC2
CR-U120AC2
CR-U230AC2
CR-U012DC3
CR-U024DC3
CR-U048DC3
CR-U110DC3
CR-U125DC3
CR-U220DC3
CR-U024AC3
CR-U048AC3
CR-U060AC3
CR-U110AC3
CR-U120AC3
CR-U230AC3
CR-U012DC2L
CR-U024DC2L
CR-U048DC2L
CR-U110DC2L
CR-U220DC2L
CR-U024AC2L
CR-U048AC2L
CR-U110AC2L
CR-U120AC2L
CR-U230AC2L
CR-U012DC3L
CR-U024DC3L
CR-U048DC3L
CR-U110DC3L
CR-U220DC3L
CR-U024AC3L
CR-U048AC3L
CR-U110AC3L
CR-U120AC3L
CR-U230AC3L

1SVR405621R4000  
1SVR405621R1000
1SVR405621R6000
1SVR405621R8000
1SVR405621R9000
1SVR405621R0000
1SVR405621R5000
1SVR405621R7000
1SVR405621R2000
1SVR405621R3000
1SVR405622R4000
1SVR405622R1000
1SVR405622R6000
1SVR405622R8000
1SVR405622R8200
1SVR405622R9000
1SVR405622R0000
1SVR405622R5000
1SVR405622R5200
1SVR405622R7000
1SVR405622R2000
1SVR405622R3000
1SVR405621R4100
1SVR405621R1100
1SVR405621R6100
1SVR405621R8100
1SVR405621R9100
1SVR405621R0100
1SVR405621R5100
1SVR405621R7100
1SVR405621R2100
1SVR405621R3100
1SVR405622R4100
1SVR405622R1100
1SVR405622R6100
1SVR405622R8100
1SVR405622R9100
1SVR405622R0100
1SVR405622R5100
1SVR405622R7100
1SVR405622R2100
1SVR405622R3100

Type

Order code

Price

Pkg Weight
(1 pce)
qty kg (lb)

10

0.083
(0.183)

10

0.083
(0.183)

10

0.083
(0.183)

10

0.083
(0.183)

Ordering details - Accessories
Version

CR-U2S
Socket for 2 c/o and module
Socket for 3 c/o and module
Socket for 3 c/o
Socket small for 2 c/o
Socket small for 3 c/o
Holder for CR-U socket

CR-U2S
CR-U3S
CR-U3E
CR-U2SM
CR-U3SM
CR-UH

1SVR405670R0000
1SVR405660R0000
1SVR405660R0100
1SVR405670R1100
1SVR405660R1100
1SVR405669R0000

Price

Pkg Weight
(1 pce)
qty kg (lb)

10

Bold printed products = stocked products

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/12

5

Pluggable interface relays
Ordering details
Ordering details - CR-U range (all products stocked)
Rated control
supply voltage

Description

Version

Type

Order code

Price

Pkg Weight
(1 pce)

6-24 V DC

CR-U...

24-60 V DC
110 V DC

5

6-24 V AC/DC
24-60 V AC/DC
110-230
V AC/DC

Diode and
LED - Reverse polarity
protection/
free wheeling
diode

Diode and
LED

6-24 V AC/DC
Varistor and
LED
Overvoltage
protection

2CDC 291 032 F0005

110 V DC
110-230 V AC

CR-U T

24 V AC
115 V AC
230 V AC
24-240
V AC/DC

1SVR405661R0000

CR-U 41
red, A1+, A2green, A1+, A2- CR-U 41V
red, A1+, A2red, A1+, A2-

red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2red, for DC
A1+, A2green, for DC
A1+, A2-

Overvoltage
protection,
varistor
Multifunction
time module

pluggable
onto CR-U2S
and CR-U3S

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

10

0.007
(0.015)

CR-U 51B
CR-U 51D

1SVR405662R0000
1SVR405662R1000
1SVR405662R4000
1SVR405662R4100
1SVR405662R9000
1SVR405662R9100
1SVR405663R0000
1SVR405663R4000

CR-U 51C

1SVR405663R1000

CR-U 61

1SVR405664R0000

CR-U 61V

1SVR405664R1000

CR-U 61E

1SVR405664R4000

CR-U 61EV

1SVR405664R4100

CR-U 91

1SVR405664R0100

CR-U 91V

1SVR405664R1100

CR-U 61C

1SVR405665R0000

CR-U 61CV

1SVR405665R1000

CR-U 61D

1SVR405665R4000

CR-U 61DV

1SVR405665R4100

CR-U 91C

1SVR405665R0100

CR-U 91CV

1SVR405665R1100

CR-U 71
CR-U 71A
CR-U 81

1SVR405666R0000
1SVR405666R1000
1SVR405666R2000

10

0.007
(0.015)

CR-U T

1SVR405667R0000

10

0.014
(0.031)

CR-U 41B

green, A1+, A2- CR-U 41BV

Spark quenching

110 V DC
110-230 V AC

24-60 V AC/DC

CR-U 21

CR-U 41C

green, A1+, A2- CR-U 41CV

6-24 V AC/DC

24-60 V AC/DC

A1+, A2-

All CR-U modules can be plugged onto sockets CR-U2S and CR-U3S.

2CDC 292 013 F0005

2CDC 292 014 F0005

Connection diagrams

CR-U 41, 	 CR-U 41B, 	 CR-U 41C,	
CR-U 41V, 	 CR-U 41BV,	 CR-U 41CV

CR-U 61, 	 CR-U 61E,	 CR-U 91,	
CR-U 61V, 	 CR-U 61EV,	 CR-U 91V

CR-U 51B,	 CR-U 51C	 CR-U 51D,

2CDC 292 017 F0005

2CDC 292 016 F0005

CR-U 21

2CDC 292 015 F0005

6-220 V DC

Diode Reverse
polarity
protection/
free wheeling
diode

2CDC 292 018 F0005

2CDC 291 004 S0011

qty kg (lb)

CR-U 61C,	 CR-U 61D,	 CR-U 91C,	
CR-U 61CV,	 CR-U 61DV	 CR-U 91CV

5/13 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

CR-U 71, 	
71A,	

CR-U 81	

CR-U

Pluggable interface relays
Technical data
Input circuit - coil data
CR-P range
Rated
control
supply
voltage
US

Rated
frequency

Make
voltage
(at 20 °C)

Maximum
voltage
(at 55 °C)

Break
voltage

Rated
power

Coil
resistance
(at 20 °C)

Tolerance
of coil
resistance

DC coils

  12 V DC
  24 V DC
  48 V DC
110 V DC

-

   8.4 V DC
  16.8 V DC
  33.6 V DC
  77 V DC

  30.6 V DC
  61.2 V DC
122.4 V DC
280 V DC

 0.1 US
 0.1 US
 0.1 US
 0.1 US

0.4-0.48 W
0.4-0.48 W
0.4-0.48 W
0.4-0.48 W

  360 
 1440 
 5700 
25200 

 10%
 10%
 10%
 10%

AC coils

  24 V AC
  48 V AC
110 V AC
120 V AC
230 V AC

50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz

  19.2 V AC
  38.4 V AC
  88 V AC
  96 V AC
184 V AC

  28.8 V AC
  57.6 V AC
132 V AC
144 V AC
276 V AC

 0.15 US
 0.15 US
 0.15 US
 0.15 US
 0.15 US

0.75 VA
0.75 VA
0.75 VA
0.75 VA
0.75 VA

  400 
 1550 
 8900 
10200 
38500 

 10%
 10%
 10%
 10%
 10%

Rated
frequency

Make
voltage
(at 20 °C)

Maximum
voltage
(at 55 °C)

Break
voltage

Rated
power

Coil
resistance
(at 20 °C)

Tolerance
of coil
resistance

  12 V DC
  24 V DC
  48 V DC

-

   9.6 V DC
  19.2 DC
  38.4 V DC

  13.2 V DC
  26.4 V DC
  52.8 V DC

 0.1 US
 0.1 US
 0.1 US

0.9 W
0.9 W
0.9 W

  160 
  640 
 2600 

 10%
 10%
 10%

  60 V DC
110 V DC
125 V DC
220 V DC

-

48.0 V DC
  88 V DC
100 V DC
176 V DC

66.0 V DC
121 V DC
137,5 V DC
242 V DC

 0.1 US
 0.1 US
 0.1 US
 0.1 US

0.9 W
0.9 W
0.9 W
0.9 W

4000 
13600 
16000 
54000 

 10%
 10%
 10%
 10%

  24 V AC
  48 V AC
60 V AC
110 V AC
120 V AC
230 V AC

50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz
50 / 60 Hz

  19.2 V AC
  38.4 V AC
48.0 V AC
  88 V AC
  96 V AC
184 V AC

  26.4 V AC
  52.8 V AC
66.0 V AC
121 V AC
132 V AC
253 V AC

 0.2 US
 0.2 US
 0.2 US
 0.2 US
 0.2 US
 0.2 US

1.6 VA
1.6 VA
1.6 VA
1.6 VA
1.6 VA
1.6 VA

  158 
  640 
930 
 3450 
 3770 
16100 

 10%
 10%
 10%
 10%
 10%
 10%

Rated
frequency

Make
voltage
(at 20 °C)

Maximum
voltage
(at 55 °C)

Break
voltage

Rated
power

Coil
resistance
(at 20 °C)

Tolerance
of coil
resistance

-

9.6 V DC
19.2 V DC
38.4 V DC
88.0 V DC
96.0 V DC
176.0 V DC

13.2 V DC
26.4 V DC
52.8 V DC
121.0 V DC
132.0 V DC
242.0 V DC

 0.1 Us
 0.1 Us
 0.1 Us
 0.1 Us
 0.1 Us
 0.1 Us

1.5 W
1.5 W
1.5 W
1.5 W
1.5 W
1.5 W

  110 
  430 
 1750 
 9200 
11000 
37000 

 10 %
 10 %
 10 %
 10 %
 10 %
 10 %

2.8 VA (50 Hz)
2.5 VA (60 Hz)
2.8 VA (50 Hz)
2.5 VA (60 Hz)
2.8 VA (50 Hz)
2.5 VA (60 Hz)
2.8 VA (50 Hz)
2.5 VA (60 Hz)
2.8 VA (50 Hz)
2.5 VA (60 Hz)
2.8 VA (50 Hz)
2.5 VA (60 Hz)

   75 

 10 %

  305 

 10 %

  475 

 10 %

 1700 

 10 %

 1910 

 10 %

 7080 

 10 %

5

CR-M range
Rated
control
supply
voltage
US
DC coils

AC coils

CR-U range
Rated
control
supply
voltage
US
DC coils

12 V DC
24 V DC
48 V DC
110 V DC
125 V DC
220 V DC

AC coils

24 V AC

50 / 60 Hz

19.2 V AC

26.4 V AC

 0.15 Us

48 V AC

50 / 60 Hz

38.4 V AC

52.8 V AC

 0.15 Us

60 V AC

50 / 60 Hz

48.0 V AC

66.0 V AC

 0.15 Us

110 V AC

50 / 60 Hz

88.0 V AC

121.0 V AC

 0.15 Us

120 V AC

50 / 60 Hz

96.0 V AC

132.0 V AC

 0.15 Us

230 V AC

50 / 60 Hz

184.0 V AC

253.0 V AC

 0.15 Us

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/14

Pluggable interface relays
Technical data
Type

CR-P...1

CR-M...2

Output circuit(s)

11-12/14

11-12/14
21-22/24

Kind of output

Relay, 1 c/o

Contact material

AgNi

Relay, 2 c/o
Relay, 2 c/o
AgNi
AgNi/Au 5 µm AgNi

Rated operational voltage Ue (VDE 0110, IEC 60947-1)

250 V

Minimum switching voltage
Maximum switching voltage

11-12/14
21-22/24

5V

10 V

DC

300 V DC

250 V DC

AC

440 V AC

CR-M...3

CR-M...4

CR-U...2

AgNi

11-12/14
21-22/24
31-32/34
41-42/44
Relay, 4 c/o
AgNi
AgNi/Au 5 µm

10 V

5V

5 mA

11-12/14
21-22/24
31-32/34
Relay, 3 c/o

250 V AC

11-12/14
21-22/24
31-32/34

Relay, 2 c/o

Relay, 3 c/o

AgNi
10 V
440 V AC

16 A

12 A

10 A

2 mA
(AgNi/Au)
6A

AC12 (resistive) 230 V

16 A

8A

12 A

10 A

6A

10 A

current

AC15 (inductive) 230 V

1.5 A

1.5 A

1.5 A

1.5 A

1A

1.5 A

(IEC 60947-5-1)

AC15 (inductive) 120 V

3A

5 mA (AgNi)

Rated free air thermal current Ith
Rated ­operational

(UL 508)

8A

12 A

10 A

6A

10 A

2.5 A

2A

2.5 A

2.5 A

2A

2A

0.22 A

DC13 (inductive) 250 V

0.1 A

max. rated operational voltage
Max. continuous thermal current
at utilization category
Max. making / breaking apparent
power at utilization category
Utilization category (resistive)
(CSA22.2 No.14....)

(UL 508;
NEMA ICS-5)

10 A

16 A

(Contact rating code designation)

Utilization category (pilot duty)

DC rating *

5 mA (AgNi)

DC12 (resistive) 24 V

Utilization category (pilot duty)

AC rating

5 mA (AgNi)

DC13 (inductive) 24 V
DC13 (inductive) 120 V

(Contact rating code designation)
Max. rated operational voltage
Max. continuous thermal current
at utilization category
Max. making / breaking apparent
power at utilization category
Utilization category (resistive)
(CSA22.2 No.14....)

B300

B300

-

B300

300 V AC

300 V AC

-

300 V AC

5A

5A

2.5 A

-

5A

3600 / 360 VA

3600 / 360 VA

1800 /
180 VA

-

3600/360 VA

16 A,
250 V AC

5A

8 A,
250 V AC

10 A, 250 V AC 6 A, 250 V AC 5 A, 250 V AC 10 A,
12 A, 150 V AC 10 A, 150 V AC 10 A, 150 V AC 250 V AC

10 A,
24 V DC

-

R300
300 V DC
1A
28 VA
-

10 A,
28 V DC

Maximum making (inrush) current

30 A

Minimum switching power

0.3 W (AgNi), 0.05 W (AgNi/Au) 0.3 W (AgNi), 0.1 W (AgNi/Au)

Maximum switching (breaking) power

AC1 (resistive)

Contact resistance

CR-U...3

11-12/14
31-32/34

2 mA
(AgNi/Au)
8A

Minimum switching current

5

CR-P...2

4000 VA

24 A
2000 VA

3000 VA

20 A
2500 VA

12 A

20 A

1500 VA

2500 VA

0.3 W

 100 m

Maximum operating frequency

rated load AC-1
without load

600 switching cycles/h

1200 switching cycles/h

72000 switching cycles/h

18000 switching cycles/h

> 3 x 107 switching cycles
> 0.7 x 10 5
> 10 5
switching
switching
cycles
cycles
(16 A, 250 V) (8 A, 250 V)
see reduction factor F

> 2 x 107 switching cycles
> 10 5 switching cycles

Response time

typ. 7 ms

typ. 13 ms (DC),10 ms (AC)

typ. 18 ms (DC), 12 ms (AC)

Release time

typ. 3 ms

typ. 3 ms (DC), 8 ms (AC)

typ. 7 ms (DC), 10 ms (AC)

Rated insulation voltage

400 V AC

250 V AC

Insulation class

C250 / B400

C250 / B250

between coil and contacts

5 kV AC

2.5 kV AC

between open contacts

1 kV AC

Mechanical lifetime
Electrical lifetime

electrical AC1
(resistive)
cos ϕ

(12 A, 250 V)

(10 A, 250 V)

12000 switching cycles/h

(6 A, 250 V)

> 10 5 switching cycles
(10 A, 250 V)

Isolation data

Rated impulse
withstand
voltage Uimp

between c/o (SPDT) contacts

-

C250

1.5 kV AC
2.5 kV AC

2.5 kV AC

* Those ratings are based on different type tests but they are not covered by the cULus or CSA approvals.

5/15 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

 2 kV AC

2 kV AC

Pluggable interface relays
Technical data, Load limit curves
Type

CR-P...1

Clearance	

between coil and
contacts

 10 mm

Creepage distance	

between coil and
contacts

CR-P...2

CR-M...2

CR-M...3

 2.5 mm

CR-M...4

CR-U...2

 1.6 mm

 3 mm

CR-U...3

 10 mm

 4 mm

 3.2 mm

 4.2 mm

Overvoltage category

III

III

II

III

Pollution degree

3

3

2

3

Dimensions (W x H x D) when mounted

12.7 x 29 x 15.7 mm

21.2 x 27.5 x 35.6 mm

35 x 35 x 54.4 mm

Weight

14 g (0.031 lb)

35 g (0.077 lb)

83 g (0.18 lb)

Mounting

on socket (see accessories)

Mounting position

any

Degree of protection

IP 67

General data

IP 40

Electrical connection
Connection

by socket

5

Environmental data
Ambient temperature range

operation
storage

Vibration resistance 10-150 Hz
Shock resistance

DC: -40...+85 °;
AC: -40...+70 °C

DC: -40...+70 °; AC: -40...+55 °C

-40 ... +85 °C

n/o contact

10 g

n/c contact

10 g

5g

5g
5g

5g
5g

n/o contact

30 g

20 g

10 g

10 g

n/c contact

30 g

20 g

5g

10 g

EN 60810-1, EN 60255-23, IEC 61810-7

EN 60255-1-00

Standards
Product standard

EN 61810-1, EN 60255-23
IEC 60664-1

Low Voltage Directive

2006/95/EC

Approvals see page 5/6.

Load limit curves - Maximum switching power at resistive DC load
CR-U with 2 and 3 c/o contacts

DC current [A]

CR-M with 4 c/o contacts

2 = inductive load, T = 40 ms

DC voltage [V]

DC voltage [V]

2CDC 292 023 F0204

1 = resistive load, T = 0 ms

2CDC 292 019 F0204

2CDC 292 015 F0204

DC current [A]

DC voltage [V]

DC voltage [V]

DC current [A]

CR-M with 3 c/o contacts

DC current [A]

CR-M with 2 c/o contacts

DC voltage [V]

2 = inductive load, T = 40 ms

2CDC 292 010 F0204

2CDC 292 005 F0204

DC current [A]

DC voltage [V]

1 = resistive load, T = 0 ms

2CDC 292 028 F0204

CR-P with 2 c/o contacts

DC current [A]

CR-P with 1 c/o contact

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/16

Pluggable interface relays
Load limit curves
Load limit curves - Electrical lifetime at resistive AC load
CR-P with 2 c/o contacts

CR-M with 4 c/o contacts

Switching power [kVA]

2CDC 292 022 F0204

Switching power [kVA]

2CDC 292 018 F0204

Switching cycles

Switching cycles
2CDC 292 013 F0204

Switching power [kVA]

Switching power [kVA]

2CDC 292 027 F0204

Switching cycles

CR-M with 3 c/o contacts

Switching cycles

CR-M with 2 c/o contacts

Switching power [kVA]

2CDC 292 009 F0204

2CDC 292 003 F0204

Switching power [kVA]

5

CR-U with 2 and 3 c/o contacts

Switching cycles

Switching cycles

CR-P with 1 c/o contact

Reduction factor F at inductive AC load
CR-U

5/17 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Power factor

2CDC 292 029 F0204

Power factor

2CDC 292 014 F0204

Power factor

2CDC 292 004 F0204

Reduction factor

Reduction factor

CR-M

Reduction factor

CR-P

Pluggable interface relays
Connection diagrams

CR-P with 1 c/o contact

CR-M with 2 c/o contacts

2CDC 292 024 F0004

2CDC 292 016 F0004

2CDC 292 011 F0004

2CDC 292 001 F0004

Connection diagrams

CR-M with 3 c/o contacts

CR-U with 2 c/o contacts

CR-P with 2 c/o contacts

2CDC 292 030 F0004

2CDC 292 008 F0004

2CDC 292 020 F0004

5

CR-M with 4 c/o contacts

CR-U with 3 c/o contacts

Dimensional drawings	

2CDC 292 002 F0004

2CDC 292 012 F0004

2CDC 292 025 F0004

Dimensions in mm and inches

CR-U with 2 c/o contacts

CR-M with 2 c/o contacts

2CDC 292 017 F0004

2CDC 292 026 F0004

CR-P

CR-U with 3 c/o contacts

2CDC 292 021 F0004

CR-M with 3 c/o contacts

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/18

Pluggable interface relays
Connection diagrams
Dimensional drawings	

Dimensions in mm and inches

Sockets for screw connection

Marker

62

Marker

42,6

27,2
27,2

27,2

24

51,2

15,8
7,5

Relay

76

20
2CDC 292 006 F0211

35,4

Pluggable
function module

CR-M2SS - CR-M3SS - CR-M4SS

Holder
Pluggable
function module

60,8

27,2 Marker
27,2

42,6

27,2

24

CR-PLS
2CDC 292 003 F0211

61

3.2

CR-M3LS

CR-M2LS - CR-M3LS - CR-M4LS

78.5

50

75,3

75,3

9 - M3

4
29,8

29,8

CR-U2S

CR-PLSx

CR-U3S

CR-U2S - CR-U3S

2CDC 292 081 F0004

Marker

42.8

CR-U3E

Holder

76

10

35,4

24

12 - M3

2CDC 292 008 F0011

Pluggable function module

15.5

24

11 - M3

61,8
CR-U2SM

CR-PSS

5/19 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

26

27,8

8 - M3

61,8

2CDC 292 009 F0011

Pluggable
function module

38,1

38,1
27,8

CR-U3SM

CR-U2SM

4

2CDC 292 002 F0005

Relay

35,4

20

38,1

Holder

7.62

15,8

Pluggable
function module

29,1

CR-M4LS

37,3

29.4
2CDC 292 033 F0004

CR-M2LS

Holder

Relay

5.08

20.32

5.08

42.5

35,4

75

Relay

62

2CDC 292 007 F0211

5

Relay

Holder

2CDC 292 004 F0211

10

75,2

29

CR-U3SM

Pluggable interface relays
Connection diagrams
Dimensional drawings	

Dimensions in mm and inches

Sockets for spring connection
43,5

42,5

33,8
7,62

33,2
31

24

95

16,3

27

26

34,4

79,5

CR-PLC

2CDC 292 006 F0005

5,5

25,9

20,32

5,08

97,5

2CDC 292 010 F0011

5,08

15

12,4

12,4

24,4

5

CR-M2LC , CR-M4LC

Jumper

2±0,2

6±0,2

1

9,5

10

R1

2CDC 292 011 F0011

9 x 27.2 (=244,8)
27.2 ±0.2

246.8

CR-PJ

±0,2

2±0,2

R1

1,5

10
10

6±0,2

2CDC 292 012 F0011

9x15 (=139,5)
15,5

141,5+1

CR-MJ

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/20

Interface relays and optocouplers R500 / R600 range
Product group picture

5

5/21 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays and optocouplers R500 / R600 range
Table of contents
Interface relays and optocouplers R500/R600 range
Table of contents	

5/22

Benefits and advantages	

5/23

Type designators	

5/24

Interface relays and optocouplers R500 range	

5/25

Table of contents	

5/26

Interface relays R500 range	

5/27

Table of contents	

5/28

Selection	

5/29

Ordering details	

5/30

Technical information	

5/31

Notes	

5/32

Optocouplers R500 range	

5/33

Table of contents	

5/34

Selection	

5/35

Ordering details	

5/36

Connection diagrams	

5/37

Technical data	

5/38

Interface relays and optocouplers R600 range	

5/45

Table of contents	

5/46

Interface relays R600 range	

5/47

Table of contents	

5/48

Benefits and advantages	

5/49

Selection	

5/51

Ordering details	

5/53

Connection diagrams	

5/55

Technical data	

5/56

General technical data	

5/61

Dimensional drawings, Load limit curves	

5/62

Optocouplers R600 range	

5/63

Table of contents	

5/64

Selection	

5/65

Ordering details	

5/67

Connection diagrams	

5/68

Technical data	

5/69

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/22

5

5

2CDC 291 024 F0013

2CDC 291 002 F0013

Interface relays and optocouplers R500 / R600 range
Benefits and advantages

R500 series

R600 series

It is our range offering pluggable functions

Standard range in screw clamp or spring clamp versions

	 Spacing : 5.08 mm (the smallest in the market)
	 Wire size : 2.5 mm² (4 mm² solid)
	 Contact type : 1 SPDT from 10 mA to 6 A / 250 V

	 Spacing : 6 mm or 12 mm
	 Wire size : 2.5 mm² (4 mm² solid wire)
	 Contact type : 1 NO, 1 NC, 1 SPDT, 1 DPDT from
1 mA to 8 A / 250 V

In today’s automation systems, PLCs are the core of industry. They link sensors and actuators to the process, which are connected to the PLC via
conventional wires.
However these PLCs are not completely isolated from the industrial environment, hence over voltage picks and transient currents can affect their operating functions. And additionally, their application field is often limited to 24 VDC / 100 mA.
So, with the aim to adapt application voltage and/or current and provide as well the right electrical isolation to the PLC, it is recommended to install per
I/O the right interface providing both voltage-current level adaptation and isolation protection.
This interfacing is possible thanks to ABB’s relays and optocouplers ranges, which offer wide adaptation in both voltage (from 5 to 400 V) and current
(from 10-7 to 16 A) as well as high isolation between input and output from 2 to 4 KV.

5/23 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays and optocouplers R500 / R600 range
Type designators
	
SERIES	
CODE	
NB OF RELAYS	
CONTACT TYPE	
NB OF CONTACTS	
					
PER RELAY
	
R 600
		
R B
	
	

R 600	

R

B

PARTICULARITIES

R

		
	

R 500	

D 2,5/5 R

		
				
				0		
None
			 1	1	1	A
				2	
2	
B
						R
						I

5

Features

Description of contact types

None	
A	
	

0	

1 Normally Closed	

1 NC

1	

1 Normally Open	

1 NO			

2	

1 Change Over or Single Pole Double Through

Input voltage	
Input voltage	

DC
AC/DC		

R	
	
	

RC circuit protection : 	
- Input protection against leakage current

	

- Increases relay contacts life

Switch to force the coil for maintenance and/or installation 		
I	
	purposes
Auto A1
off
Manu
A3

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/24

Interface relays and optocouplers R500 range
Product group picture

5

5/25 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays and optocouplers R500 range
Table of contents
Interface relays and optocouplers R500 range
Product group picture	

5/25

Table of contents	

5/26

Interface relays R500 range	

5/27

Product group picture	

5/27

Table of contents	

5/28

Selection	

5/29

Ordering details	

5/30

Technical information	

5/31

Optocouplers R500 range	

5/33

Product group picture	

5/33

Table of contents	

5/34

Selection	

5/35

Ordering details	

5/36

Connection diagrams	

5/37

Technical data	

5/38

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/26

5

Interface relays R500 range
Product group picture

5

5/27 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays R500 range
Table of contents
Interface relays R500 range
Table of contents	

5/28

Selection	

5/29

Ordering details	

5/30

Technical information	

5/31

Notes	

5/32

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/28

1SNA 645 047 R0000

1SNA 645 547 R0200

D 2,5/5-R121AL-48VAC/DC 1SNA 645 521 R2000

1SNA 645 549 R1400

D 2,5/5-R121L-24VDC

D 2,5/5-R121AL-24VAC/DC 1SNA 645 021 R2600

1SNA 645 049 R1200

D 2,5/5-R121-24VDC

D 2,5/5-R121BL-110VAC

D 2,5/5-R121BL-230VAC

1

1

1

1

1

1

Input voltage
24 V DC

2CDC 291 015 F0011

Order number

5

Type

Interface relays R500 range
Selection

R500 series
Characteristics

	 Spacing : 5.08 mm (the smallest in the market)
	 Wire size : 2.5 mm² (4 mm² solid)
	 Contact type : 1 SPDT from 10 mA to 6 A / 250 V

48 V DC
24 V AC
48 V AC
110 V AC
230 V AC
Output rating
10 mA - 6 A
Output contacts
c/o
Type
with LED
without LED

5/29 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays R500 range
Ordering details
Description of R500 Relay

Type

Relay module 1 SPDT high level

Order code

Price

D 2,5/5-R121-24VDC

1SNA607217R0200

D 2,5/5-R121L-24VDC

1SNA607201R1300

0.032
(0.071)

2CDC 291 015 F0011

D 2,5/5-R121AL-24VAC/DC 1SNA607231R0000
Relay module with LED 1 SPDT high level D 2,5/5-R121AL-48VAC/DC 1SNA607232R0100

R500 Accessories

D 2,5/5-R121BL-110VAC

1SNA607264R1100

D 2,5/5-R121BL-230VAC

1SNA607265R1200

Type

Order code

BAMH	
High end stop

9,1 mm

1SNA114836R0000

BAMH V0	 9,1 mm

1SNA194836R0100

BADH	

1SNA116900R2700

12 mm

Comb type jumper bar 2 to 22 poles

BNMS R24V-...

BAMH

DCB

FC2

PCMS

BADH

0.04
(0.088)

Pkg Weight
qty (1 pce)
kg (lb)
50

consult us

Jumper bar 10 poles	 grey

PCMS	V0

1SNA205523R2200

Relay / Opto base

D 2,5/5-MP

1SNA607224R0100

Relay / Opto base with LED 24 VDC

D 2,5/5-MP-24VDC

1SNA607222R0700

Relay / Opto base with LED 24 VAC/VDC

D 2,5/5-MP-24VAC/DC

1SNA607260R2100

Relay / Opto base with LED 48 VAC/VDC

D 2,5/5-MP-48VAC/DC

1SNA607261R1600

Relay / Opto base with LED 110 VAC

D 2,5/5-MP-110VAC

1SNA607266R1300

Relay / Opto base with LED 230 VAC

D 2,5/5-MP-230VAC

1SNA607267R1400

Plug relay 24 V 1 SPDT 10 mA to 6 A

BNMS R24V-1

1SNA031820R1400

Plug relay 24 V 1 SPDT 1 mA to 6 A

BNMS R24V-2

1SNA031847R1300

Test device blue

DCB 1)

1SNA105028R2100

Test plug DIA. 2 mm

FC2

1SNA007865R2600

Marking method

RC55

see marking

1)

10

Price

R500

Pkg Weight
qty (1 pce)
kg (lb)

8
0.028
(0.062)
10

0.036
(0.0794)

4
10

Only on top decks

D2,5/5-MP...

Connection diagrams

D 2,5/5-R121

D 2,5/5-R121L

D 2,5/5-R121AL-48V

D 2,5/5-R121BL

D 2,5/5-R121AL-24V

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/30

5

Interface relays R500 range
Technical information
Technical data
Relay : 1 SPDT high level with contact 10 mA to 6 A - 5.08mm 0.200“ spacing
D 2.5/5-R121 D 2.5/5-R121L

D 2.5/5-R121AL

D 2.5/5-R121BL

Relay characteristics coil
Rated voltage: +20%, -15% on DC ; 10%, -10% on AC

24 V DC

24 V DC

Frequency

24 V DC

48 V AC

48 V DC

50/60 Hz

110 V AC

230 V AC

50/60 Hz

50/60 Hz

Power

0.17 W

0.3 W

0.35 W

0.35 W

0.44 W

0.47 W

1.08 W

2.13 W

Rated current

7 mA

12 mA

12.4 mA

10 mA

7.6 mA

6.8 mA

8.4 mA

8 mA

Drop-out voltage at 20°C

2.4 V

2.4 V

4.8 V

4.8 V

10 V

10 V

25 V

45 V

Status device

green LED

Relay characteristics contact
Type

1 SPDT

Voltage switching range min./max.

12 V / 250 V AC

Current switching range min./max.

10 mA / 6 A
AC1 min./max. 0.6 VA / 1500 VA (ohmic load)

Load switching range

DC1 min./max. 0.6 W / 140 W

Number of on-load operations

10 5 on AC15

Number of off-load operations

10 x 107

Operation speed

F 5 ms

5 ms

5 ms

5 ms

5 ms

5 ms

6 ms

7 ms

O 8 ms

8 ms

15 ms

15 ms

15 ms

15 ms

15 ms

15 ms

Insulation coil / contact

4000 V RMS

Resistance to shock coil / contact

4000 V RMS

Insulation contact / contact
Ambient temperature

1000 V RMS
storage -40 °C to -80 °C
operating See derating curves

Other characteristics
Body material

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

Wire size

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

10 mm (0.394 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending) ,

Reference standards

		
	 24 V	
	110/120 V	
	220/230 V	

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

DC12	AC12	DC13	AC15
6 A	
6 A	
1 A	
3A
0,3 A	
6 A	
0,2 A	
3A
0,2 A	
6 A	
0,1 A	
3A

Dimensional drawings

Voltage (Vcc)

5

24 V AC
50/60 Hz

1 : 24 V
2 : 48 V
3 : 110 V
4 : 230 V
Current (Acc)

D 2,5/5-R121

5/31 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays R500 range
Notes

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/32

Optocouplers R500 range
Product group picture

5

5/33 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Optocouplers R500 range
Table of contents
Optocouplers R500 range
Product group picture	

5/33

Table of contents	

5/34

Selection	

5/35

Ordering details	

5/36

Connection diagrams	

5/37

Technical data	

5/38

Notes	

5/44

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/34

1SNA 607 274 R1300
1SNA 607 210 R1700
1SNA 607 211 R0400
1SNA 607 275 R1400
1SNA 607 212 R0500
1SNA 607 213 R0600
1SNA 607 214 R0700
1SNA 607 215 R0000
1SNA 607 203 R1500
1SNA 607 204 R1600
1SNA 607 205 R1700
1SNA 607 206 R1000
1SNA 607 207 R1100

D 2,5/5-OBIC-0030-24VDC
D 2,5/5-OBIC-0030-48VDC
D 2,5/5-OBIC-0030-125VDC
D 2,5/5-OBIA-0030-24VAC
D 2,5/5-OBIA-0030-48VAC
D 2,5/5-OBIA-0030-115VAC
D 2,5/5-OBIA-0030-230VAC
D 2,5/5-OBOC-0100-5VDC
D 2,5/5-OBOC-0100-24VDC
D 2,5/5-OBOC-0100-48VDC
D 2,5/5-OBOC-1000-5VDC
D 2,5/5-OBOC-1000-24VDC

Input voltage
5 V DC

24 V DC

48 V DC

125 V DC

24 V AC

48 V AC

110 V AC

115 V AC

230 V AC

Output rating

30 mA

100 mA

2A

1A

Output voltage

30 V DC

58 V DC

253 V AC

Type

input optocoupler

output optocoupler

5/35 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

1SNA 607 271 R1000
1SNA 607 208 R2200
1SNA 607 209 R2300

D 2,5/5-OBOC-1000-230VAC
D 2,5/5-OBOC-2000-5VDC
D 2,5/5-OBOC-2000-24VDC

1SNA 607 272 R1100
1SNA 607 273 R1200
1SNA 607 238 R1700
1SNA 607 240 R2500
1SNA 607 241 R1200
1SNA 607 268 R2500
1SNA 607 269 R2600

D 2,5/5-OBOC-2000-110VAC
D 2,5/5-OBOC-2000-230VAC
D 2,5/5-OBOA-1000-24VDC
D 2,5/5-OBOA-1000-24VAC/DC
D 2,5/5-OBOA-1000-48VAC/DC
D 2,5/5-OBOA-1000-110VAC
D 2,5/5-OBOA-1000-230VAC

D 2,5/5-OBOC-2000-48VAC/DC 1SNA 607 256 R1100

D 2,5/5-OBOC-2000-24VAC/DC 1SNA 607 255 R1000

1SNA 607 270 R2300
D 2,5/5-OBOC-1000-110VAC

D 2,5/5-OBOC-1000-48VAC/DC 1SNA 607 251 R1400

D 2,5/5-OBOC-1000-24VAC/DC 1SNA 607 250 R2700

Order number

D 2,5/5-OBIC-0030-5VDC

5
Type

Optocouplers R500 range
Selection

Optocouplers R500 range
Ordering details
Description of R600
Optocoupler

Type

2CDC 291 002 F0013

Optocoupler module 30 mA/DC
Transistor

Optocoupler module 30 mA/DC
Transistor

Optocoupler module 100 mA/DC
Transistor

Optocoupler module 1 A/DC
MOS-FET

D 2,5/5-OBIC-0030-5VDC

1SNA607274R1300

D 2,5/5-OBIC-0030-24VDC

1SNA607210R1700

D 2,5/5-OBIC-0030-48VDC

1SNA607211R0400

D 2,5/5-OBIC-0030-125VDC

1SNA607275R1400

D 2,5/5-OBIA-0030-24VAC

1SNA607212R0500

D 2,5/5-OBIA-0030-48VAC

1SNA607213R0600

D 2,5/5-OBIA-0030-115VAC

1SNA607214R0700

D 2,5/5-OBIA-0030-230VAC

1SNA607215R0000

D 2,5/5-OBOC-0100-5VAC

1SNA607203R1500

D 2,5/5-OBOC-0100-24VDC

1SNA607204R1600

D 2,5/5-OBOC-0100-48VAC

1SNA607205R1700

D 2,5/5-OBOC-1000-5VDC

1SNA607206R1000

D 2,5/5-OBOC-1000-24VDC

1SNA607207R1100

Optocoupler module 1 A/AC
Thyristor

BNMS P...

1SNA607271R1000

D 2,5/5-OBOC-2000-5VDC

1SNA607208R2200

D 2,5/5-OBOC-2000-24VDC

1SNA607209R2300

D 2,5/5-OBOC-2000-24VAC/DC 1SNA607255R1000
D 2,5/5-OBOC-2000-48VAC/DC 1SNA607256R1100
D 2,5/5-OBOC-2000-110VAC
1SNA607272R1100
D 2,5/5-OBOC-2000-230VAC

1SNA607273R1200

D 2,5/5-OBOA-1000-24VDC

1SNA607238R1700

D 2,5/5-OBOA-1000-24VAC/DC

BAMH

PCMS

BADH

0.032
(0.071)

1

0.032
(0.071)

1

0.032
(0.071)

1

0.04
(0.088)

1

0.04
(0.088)

1SNA607240R2500

0.032
(0.071)
1

D 2,5/5-OBOA-1000-48VAC/DC 1SNA607241R1200
D 2,5/5-OBOA-1000-110VAC

1SNA607268R2500

D 2,5/5-OBOA-1000-230VAC

1SNA607269R2600

Type

Order code

BAMH 9.1 mm

1SNA114836R0000

BAMH V0 9.1 mm

1SNA194836R0100

BADH 12 mm

1SNA116900R2700

Comb type jumper bar 2 to 22 poles

1

1SNA607270R2300

D 2,5/5-OBOC-1000-230VAC

Description of Accessories

Pkg Weight
qty (1 pce)
kg (lb)

5

D 2,5/5-OBOC-1000-48VAC/DC 1SNA607251R1400

High end stop

D2,5/5-MP...

Price

D 2,5/5-OBOC-1000-24VAC/DC 1SNA607250R2700
D 2,5/5-OBOC-1000-110VAC

Optocoupler module 2 A/DC
MOS-FET

Order code

Price

0.04
(0.088)

Pkg Weight
qty (1 pce)
kg (lb)
50

consult us

Jumper bar 10 poles grey

PCMS V0

1SNA205523R2200

8

Input opto base

D 2.5-5-MP1

1SNA607223R0000

10

Plug OBIC 5 V white

BNMS T5V-1

1SNA031831R0300

Plug OBIC 24 V white

BNMS T24V-1

1SNA031800R2100

Plug OBIC 48 V white

BNMS T48V-1

1SNA031801R1600

Plug OBIC 125 V white

BNMS T125V-1

1SNA031845R1100

Test device blue

DCB (1)

1SNA105028R2100

Test plug DIA 2 mm

FC2

1SNA105028R2100

Marking method

RC55

see marking

0.028
(0.062)

4

10

FC2

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/36

Optocouplers R500 range
Connection diagrams

IN

IN

D 2,5/5-OBIA-0030

D 2,5/5-OBIC-0030

5

IN

D 2,5/5-OBOC-0100

IN
IN

D 2,5/5-OBOC-1000
24/48 VAC/DC
110/230 VAC

D 2,5/5-OBOC-1000 5/24 VDC

IN

D 2,5/5-OBOA-1000

5/37 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

IN

D 2,5/5-OBOC-2000

Optocouplers R500 range
Technical data
Technical data
Pluggable optocoupler : 5 to 58 V DC output / 30 mA - 5.08 mm 0.200“ spacing
D 2,5/5-OBIC-0030
Input
Input voltage

4.5 V to 5.5 VDC

19.2 V to 27.6 VDC

38.4 V to 55.2 VDC

93.5 V to 140 VDC

Input current

6 mA

5 mA

4.1 mA

3 mA

Pull-in voltage at Is=100%

3.5 V

12 V

21 V

50 V

Switching time C / O

20 µs / 1.3 ms

Operating frequency

400 Hz
1 mA

0.8 mA

Permissible leakage current

Output
Output voltage

4.5 to 58 V DC

Output current min.

0.5 mA

Output current max.

30 mA

Output leakage current at Umax.
Redidual voltage at I max and U rated

5

< 50 µA
typical 2.3 V DC
max 2.7 V DC

Frequency on inductive load
Isolation Input / Output
Ambient temperature

input / Output 2500 V RMS
storage -40...+80 °C
operating See derating curve

Other characteristics
Body material
Wire size

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals
Reference standards

(pending),
CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Derating curve

Dimensional drawings
1 : 5 V - 24 V - 48 V
2 : 115 V

A1
D 2,5/5-OBIC-0030

14

A2

13
center of rail

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/38

Optocouplers R500 range
Technical data
Technical data
Pluggable optocoupler : 5 to 58 V DC output / 30 mA - 5.08 mm 0.200“ spacing
D 2,5/5-OBIA-0030
Input
Input voltage

5

20.4 to 26.4 V AC

40.8 V to 52.8 V AC

98 V to 126.5 V AC

195.5 V to 253 V AC

50 / 60 Hz

50 Hz

Input current

8.5 mA

4.5 mA

8 mA

7 mA

Pull-in voltage at Is=100%

13 V

22 V

50 V

95 V

Switching time C / O

6 ms / 10 ms

Operating frequency

30 Hz

Permissible leakage current

1 mA

2 mA

Output
Output voltage

4.5 V to 58 V DC

Output current min.

0.5 mA

Output current max.

30 mA

Output leakage current at Umax.
Redidual voltage at I max and U rated

< 50 µA
typical 2.3 V DC
max 2.7 V DC

Frequency on inductive load
Isolation Input / Output

2500 V RMS
input / Output

Temperature
Ambient temperature

storage -40...+80 °C
operating See derating curve

Other characteristics
Body material
Wire size

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),

Reference standards

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Dimensional drawings

Derating curve
1 : 24 V - 48 V
2 : 115 V - 230 V

A1
D 2,5/5-OBIA-0030

14
13
center of rail

5/39 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

A2

Optocouplers R500 range
Technical data
Technical data
Pluggable optocoupler : 5 to 58 V DC output / 100 mA - 5.08 mm 0.200“ spacing
D 2,5/5-OBOC-0100 5 V DC / 24 V DC

D 2,5/5-OBOC-0100 48 V DC

Input
Input voltage

4.5 V to 5.5 V DC

20.4 V to 28.8 V DC

40.8 V to 57.6 V DC

Input current

8.5 mA

4.8 mA

3.9 mA

Pull-in voltage at Is=100%

2.9 V DC

16 V DC

26 V DC

Switching time C / O

20 µs / 1.3 ms

Operating frequency

400 Hz

Permissible leakage current

1 mA

Frequency

5

Output
Output voltage

4.5 V to 58 V DC

Output current min.

1 mA

Output current max.

100 mA

Output leakage current at Umax.

< 50 µA

Redidual voltage at I max and U rated

typical 1 V DC
max 1.3 V DC

Frequency on inductive load

See Note 1

Isolation Input / Output

input / Output 2500 V RMS

Temperature
storage -40...+80 °C

Ambient temperature

operating See derating curve

Other characteristics
Body material

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

Wire size

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),

Reference standards

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Note 1 :

or

Fmax = (1-0,007 x Us) / (L x Is²)
Fmax = (1-0,007 x Us) / (P x

L
)
R

Us	
Is	
L	
P	
R	

= Output voltage
= Output current
= Inductance of load
= Power of load
= Resistance of load

Dimensional drawings

A1

Derating curve
14

A2

13
center of rail

D 2,5/5-OBOC-0100 5 V DC / 24 V DC

D 2,5/5-OBOC-0100 48 V DC

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/40

Optocouplers R500 range
Technical data
Technical data
Pluggable optocoupler : 5 to 58 V DC output / 1 A - 5.08 mm 0.200“ spacing
D 2,5/5-OBOC-1000

D 2,5/5-OBOC-1000 24/48 V AC/DC

5/24 V DC
Input

5 V DC

24 V DC

Input voltage

4.5 - 5.5
V DC

Input current

24 V AC

24 V DC

20.4 - 28.8
V DC

24 ± 10 %

12.3 mA

6.7 mA

Pull-in voltage at Is=100%

3.5 V DC

10 V DC

Switching time C / O

20 / 250 µs

Operating frequency

2000 Hz

110/230 V AC

48 V AC

48 V DC

20.4 - 28.8
V DC

48 ± 10 %

40.8 to 57.6 110 ± 10 %
V DC
50 / 60 Hz

50 / 60 Hz

10.5 mA

8 mA

6.8 mA

5.8 mA

8.5 mA

7.5 mA

50 / 350 µs

15 / 13 ms

5 / 13 ms

15 / 15 ms

6 / 25 ms

15 / 15 ms

15 / 15 ms

1500 Hz

20 Hz

Frequency

5

D 2,5/5-OBOC-1000

50 / 60 Hz

50 / 60 Hz

110 V AC

230 V AC
230 ± 10 %

Permissible leakage current

Output
Output voltage

4.5 V to 58 V DC

Output current min.

1 mA

Output current max.

1A

Output leakage current at Umax.

< 50 µA

Redidual voltage at I max and U rated

typical 0.1 V DC
max 0.5 V DC

Frequency on inductive load

See Note 1

Isolation Input / Output

input / Output 2500 V RMS

Temperature
storage -40...+80 °C

Ambient temperature

operating See derating curve

Other characteristics
Body material

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

Wire size

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

10 mm (0.394 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),

Reference standards

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Note 1 :
or

Fmax = (1-0,007 x Us) / (L x Is²)
Fmax = (1-0,007 x Us) / (P x

L
)
R

Us	
Is	
L	
P	
R	

= Output voltage
= Output current
= Inductance of load
= Power of load
= Resistance of load

Dimensional drawings

14

Derating curve

A1
A2
center of rail

5/41 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

13+

Optocouplers R500 range
Technical data
Technical data
Pluggable optocoupler : 5 to 30 V DC output / 2 A - 5.08 mm 0.200“ spacing
D 2,5/5-OBOC-2000

D 2,5/5-OBOC-2000 24/48 V AC/DC

5/24 V DC
Input

5 V DC

24 V DC

Input voltage

4.5 - 5.5
V DC

Input current

24 V AC

24 V DC

20.4 - 28.8
V DC

24 ± 10 %

12.3 mA

6.7 mA

Pull-in voltage at Is=100%

3.5 V DC

10 V DC

Switching time C / O

20 / 250 µs

Operating frequency

2000 Hz

D 2,5/5-OBOC-2000
110/230 V AC

48 V AC

48 V DC

20.4 - 28.8
V DC

48 ± 10 %

40.8 to 57.6 110 ± 10 %
V DC
50 / 60 Hz

50 / 60 Hz

10.5 mA

8 mA

6.8 mA

5.8 mA

8.5 mA

7.5 mA

50 / 350 µs

15 / 13 ms

5 / 13 ms

15 / 15 ms

6 / 25 ms

15 / 15 ms

15 / 15 ms

1500 Hz

20 Hz

Frequency

50 / 60 Hz

50 / 60 Hz

110 V AC

230 V AC
230 ± 10 %

5

Permissible leakage current

Output
Output voltage

4.5 V to 30 V DC

Output current min.

1 mA

Output current max.

2A

Output leakage current at Umax.

< 50 µA

Redidual voltage at I max and U rated

typical 0.1 V DC
max 0.5 V DC

Frequency on inductive load

See Note 1

Isolation Input / Output

input / Output 2500 V RMS

Temperature
storage -40...+80 °C

Ambient temperature

operating See derating curve

Other characteristics
Body material

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

Wire size

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

10 mm (0.394 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),

Reference standards

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Note 1 :
or

Fmax = (1-0,012 x Us) / (L x Is²)
Fmax = (1-0,012 x Us) / (P x

L
)
R

Us	
Is	
L	
P	
R	

= Output voltage
= Output current
= Inductance of load
= Power of load
= Resistance of load

Dimensional drawings

14

Derating curve

13+

center of rail

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/42

Optocouplers R500 range
Technical data
Technical data
Pluggable optocoupler : 24 to 253 V AC output / 1 A - 5.08 mm 0.200“ spacing
D 2,5/5-...

D 2,5/5-OBOA-1000 24 V AC/DC - 48 V AC/DC

24 V DC
Input

24 V DC

Input voltage

20.4 - 28.8
V DC

Frequency

24 V AC

24 V DC

24 ± 10 %

20.6 - 28.8
V DC

50 / 60 Hz

D 2,5/5-OBOA-1000 110 V
AC - 230 V AC

48 V AC

48 V DC

110 V AC

230 V AC

48 ± 10 %

40.8 -57.6
V DC

110 ± 10 %

230 ± 10 %

50 / 60 Hz

50 / 60 Hz

4 mA

10 mA

7 mA

6 mA

5 mA

8 mA

7.5 mA

Switching time C / O

10/20 ms

20/20 ms

10/20 ms

20/20 ms

10/20 ms

20/20 ms

20/20 ms

Operating frequency

15 Hz

Input current

50 / 60 Hz

Pull-in voltage at Is=100%

5

Permissible leakage current

Output
Output voltage

24-253 V AC - 50/60 Hz

Output current min.

25 mA

Output current max.

1A

Output leakage current at Umax.

< 0.50 mA
typical 1 V

Redidual voltage at I max and U rated

max 1.6 V

Frequency on inductive load

See Note 1

Isolation Input / Output

input / Output 2500 V RMS

Temperature
storage -40...+80 °C

Ambient temperature

operating See derating curve

Other characteristics
Body material

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)

Wire size

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

10 mm (0.394 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),

Reference standards

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Note 1 :
or

Fmax = (1-0,012 x Us) / (L x Is²)
Fmax = (1-0,012 x Us) / (P x

L
)
R

Us	
Is	
L	
P	
R	

= Output voltage
= Output current
= Inductance of load
= Power of load
= Resistance of load

Dimensional drawings

Derating curve
14

A1
A2
center of rail

5/43 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

13+

Optocouplers R500 range
Notes

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/44

Interface relays and optocouplers R600 range
Product group picture

5

5/45 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays and optocouplers R600 range
Table of contents
Interface relays and optocouplers R600 range
Product group picture	

5/45

Table of contents	

5/46

Interface relays R600 range	

5/47

Product group picture	

5/47

Table of contents	

5/48

Benefits and advantages	

5/49

Selection	

5/51

Ordering details	

5/53

Connection diagrams	

5/55

Technical data	

5/56

General technical data	

5/61

Dimensional drawings, Load limit curves	

5/62

Optocouplers R600 range	

5/63

Product group picture	

5/63

Table of contents	

5/64

Selection	

5/65

Ordering details	

5/67

Connection diagrams	

5/68

Technical data	

5/69

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/46

5

Interface relays R600 range
Product group picture

5

5/47 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays R600 range
Table of contents
Interface relays R600 range
Product group picture	

5/47

Table of contents	

5/48

Benefits and advantages	

5/49

Selection	

5/51

Ordering details	

5/53

Connection diagrams	

5/55

Technical data	

5/56

General technical data	

5/61

Dimensional drawings, Load limit curves	

5/62

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/48

Interface relays R600 range
Benefits and advantages
Characteristics

5

	 Standard range available with screw or spring-type terminals
	 8 different rated control supply voltages:
DC versions: 5 V, 12 V, 24 V
AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V
	 Output: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact, 2 c/o
(SPDT) contacts
	 Devices with output contacts protected by built in RC circuit, which result in increased contact life
	 Devices with leakage current protection on the input side
	 Available with visible or covered switch on the front of the unit, for the
configuration of manual or automatic actuation
	 With connection for jumper bar, except 2 c/o devices and some discontinued devices
	 Width: 6 mm (0.236 in) or 12 mm (0.472 in)
	 LED for the indication of the operational state
	 Accessories: Jumper bars, separator end section and distribution blocks

1

1 	 Input - Control supply voltage

2

2 	 Jumper bar connection
3 	 Indication of operational states (green LED)

3

4 	Output

4

Excellent adaption and conversion of digital signals
	
	

AC 110 V 	
DC 24 V	
DC 24 V 	
AC 230V			

	 Pushbutton	
R 600 Relay or		
	Position	
Optocoupler	
PLC	
	switch			
	Sensor

AC 110 V 	
AC 230 V

R 600 Relay or	
Optocoupler	

5/49 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

AC 380 V

Motor
contactor	

Motor

Interface relays R600 range
Benefits and advantages
Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal
amplification between control unit and process.
Boxed interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
(programmable logic controller), PC or field bus systems and the sensor / actuator level. The compact design and different connection
terminal possibilities optimize your panel installation.

5
Variety of connections
R600 relays and optocouplers are available with both screw terminals or spring
terminals.

Increased contact life
The contacts of some devices are proteced by built
in RC-circuits which result in increased contact life.

0.2 to 2.5 mm²

6 mm spacing

12 mm spacing

0.22 to 4 mm²

Functionning status
Functionning display through a green LED.

Space safing
With a width of only 6 mm or 12 mm the compact design safes space in each cabinet.

Measurement & Test
Holes for holding DIA. 2 mm test plugs to
simplify any measury or test.

Only one part number AC/DC

Approvals

H UL 508
CAN/CSA C22.2 No.14

P

Lloyds Register

pending

Marks

a

CE

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/50

1SNA 645 034 R2300

1SNA 645 036 R2500

1SNA 645 534 R2500

1SNA 645 536 R2700

1SNA 645 069 R0000

1SNA 645 037 R2600

1SNA 645 537 R2000

1SNA 645 019 R0400

1SNA 645 519 R0600

1SNA 645 014 R2700

1SNA 645 063 R0000

1SNA 645 018 R0300

1SNA 645 514 R2100

1SNA 645 563 R0200

1SNA 645 518 R0500

1SNA 645 064 R0100

1SNA 645 065 R0200

1SNA 645 001 R0300

1SNA 645 005 R0700

1SNA 645 032 R2100

1SNA 645 009 R1300

1SNA 645 033 R2200

1SNA 645 010 R0700

1SNA 645 564 R0300

1SNA 645 565 R0400

1SNA 645 501 R0500

1SNA 645 505 R0100

1SNA 645 532 R2300

1SNA 645 509 R1500

1SNA 645 533 R2400

1SNA 645 510 R0100

1SNA 645 012 R2500

1SNA 645 512 R2700

RB 121-5VDC

RB 121-5VDC

RBR 121-5VDC

RBR 121-5VDC

RB 121-12VDC

RB 121-12VDC

RBR 121-12VDC

RB 101AR-24VAC/DC

RBR 101AR-24VAC/DC

RB 111A-24VAC/DC

RB 111AI-24VAC/DC

RB 111AR-24VAC/DC

RBR 111A-24VAC/DC

RBR 111AI-24VAC/DC

RBR 111AR-24VAC/DC

RB 121-24VDC

RB 121-24VDC

RB 121A-24VAC/DC

RB 121A-24VAC/DC

RB 121AI-24VAC/DC

RB 121AI-24VAC/DC

RB 121AI-24VAC/DC

RB 121AI-24VAC/DC

RBR 121-24VDC

RBR 121-24VDC

RBR 121A-24VAC/DC

RBR 121A-24VAC/DC

RBR 121AI-24VAC/DC

RBR 121AI-24VAC/DC

RBR 121AI-24VAC/DC

RBR 121AI-24VAC/DC

RB 122A-24VAC/DC

RBR 122A-24VAC/DC

n	

n
n	

n	

n
n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n

5

	

Order number
Type

Interface relays R600 range
Selection

Input voltage
5 V DC	

n	 n	

12 V DC 	

	

	

	

	

24 V DC 	

	

	

	

	

	

	

	

48 - 60 V DC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

115 V DC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

230 V DC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

60 - 230 V DC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

24 V AC	

	

	

	

	

	

	

n	

n	

n	

n	

n	

n	

n	

n	

	

	

n	

n	

n	

n	

n	

n	

	

	

n	

n	

n	

n	

n	

n	

n	

n

48 - 60 V AC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

115 V AC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

230 V AC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

60 - 230 V AC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

Output rating
10 mA - 6 A 	

n	

	

n	

	

n	

	

	

n	

n	

n	

n	

n	

n	

n	

n	

n	

	

n	

	

n	

n	

	

	

n	

	

n	

	

n	

n	

	

	

	

	

	

	

1 mA - 6 A 	

	

n	

	

n	

	

n	

n	

	

	

	

	

	

	

	

	

	

n	

	

n	

	

	

n	

n	

	

n	

	

n	

	

	

n	

n	

	

	

	

	

1 mA - 8 A 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

n	

n	

	

	

Output contacts
c/o 	

1	1	1	1	1	1	1									 1	1	1	1	1	1	1	1	1	1	1	1	1	1	1	1	2	2						

n/o 										1	
1	
1	
1	
1	
1																						
n/c 								1	
1						

Terminal type
Screw 	

n	

n	

	

	

n	

n	

	

n	

	

n	

n	

n	

	

	

	

n	

n	

n	

n	

n	

n	

n	

n	

	

	

	

	

	

	

	

	

n	

	

	

	

Spring 	

	

	

n	

n	

	

	

n	

	

n	

	

	

	

n	

n	

n	

	

	

	

	

	

	

	

	

n	

n	

n	

n	

n	

n	

n	

n	

	

n	

	

	

5/51 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

1SNA 645 003 R0500
1SNA 645 007 R0100
1SNA 645 046 R0700
1SNA 645 503 R0700
1SNA 645 507 R0300
1SNA 645 546 R0100
1SNA 645 041 R0200
1SNA 645 541 R0400
1SNA 645 016 R2100
1SNA 645 516 R2300
1SNA 645 017 R2200
1SNA 645 517 R2400
1SNA 645 004 R0400
1SNA 645 008 R1200
1SNA 645 011 R2400
1SNA 645 504 R0000
1SNA 645 508 R1400
1SNA 645 511 R2600

RB 121A-115VAC/DC
RB 121A-115VAC/DC
RB 121AR-115VAC/DC
RBR 121A-115VAC/DC
RBR 121A-115VAC/DC
RBR 121AR-115VAC/DC
RB 122A-115VAC/DC
RBR 122A-115VAC/DC
RB 111A-115VAC/DC
RBR 111A-115VAC/DC
RB 111A-230VAC/DC
RBR 111A-230VAC/DC
RB 121A-230VAC/DC
RB 121A-230VAC/DC
RB 121AR-230VAC/DC
RBR 121A-230VAC/DC
RBR 121A-230VAC/DC
RBR 121AR-230VAC/DC

n	
n

	
	
	
n	
n	
n	
n	
n	
n	
n	
n	
n	
n

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
n	
n	
n	
n	
n	
n

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

	
n	
n	
n	
n	
n	
n	
n	
n

	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
n	
n	
n	
n	
n	
n

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
n	
n	
n	
n	
n	
n

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n

n	
	
	
n	
n

	
n	
n

	
n	
n	
n	
	
n	
	
	
	
n	
	
n	
n	
	
n	
	
	
n	
n	
n	
n	
n	
	
n	
n	
	

	
	
	
	
n	
	
n	
	
	
	
n	
	
	
n	
	
	
	
	
	
	
	
	
n	
	
	
n

	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
	
	
	

1SNA 645 520 R0300

1SNA 645 540 R1700

RBR 122A-48-60VAC/DC

n	

	

1SNA 645 020 R0100

1SNA 645 040 R1500

RB 122A-48-60VAC/DC

n	

	

RBR 121A 60-230VUC

1SNA 645 506 R0200

RBR 121A-48-60VAC/DC

n	

	

RB 121A 60-230VUC

1SNA 645 502 R0600

RBR 121A-48-60VAC/DC

n	

	

1SNA 645 513 R2000

1SNA 645 006 R0000

RB 121A-48-60VAC/DC

n	

	

1SNA 645 013 R2600

1SNA 645 002 R0400

RB 121A-48-60VAC/DC

n	

RBR 122A-230VAC/DC

1SNA 645 515 R2200

RBR 111A-48-60VAC/DC

	

	

RB 122A-230VAC/DC

1SNA 645 015 R2000

RB 111A-48-60VAC/DC

Interface relays R600 range
Selection

	
n	
n

	

n	

	

n	

n	

	

	

n	

	

n	

n	

n	

	

	

	

n	

	

n	

	

n	

	

n	

n	

n	

	

	

	

n	

	

n

	

	

n	

	

	

n	

n	

	

n	

	

	

	

n	

n	

n	

	

n	

	

n	

	

n	

	

	

	

n	

n	

n	

	

n	

	

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5

																						1	
1															1	
1	
1	
1	
						 1	1	1	1	2	2	1	1	1	1	1	1	2	2					 1	1	1	1	1	1	2	2	1	1

n

5/52

Interface relays R600 range
Ordering details

2CDC 291 024 S0013

R600 Relay

5
R600

Type

Order code

Relay module 1 NO high level 6 mm
spacing

RB 111 A-24VAC/DC
RB 111 A-48-60VAC/DC
RB 111 A-115VAC/DC
RB 111 A-230VAC/DC

1SNA645014R2700
1SNA645015R2000
1SNA645016R2100
1SNA645017R2200

Relay mod. 1 NO high level w/safety
switch 6 mm spacing

RB 111 AI-24VAC/DC

1SNA645063R0000

Relay mod. 1 NO high level w/
contact protection 12 mm spacing

RB 111 AR-24VAC/DC

1SNA645018R0300

Relay mod. 1 NC high level w/contact protection 12 mm spacing

RB 101 AR-24VAC/DC

1SNA645019R0400

Relay module 1 NO high level 6
mm spacing

RBR 111 A-24VAC/DC
RBR 111 A-48-60VAC/DC
RBR 111 A-115VAC/DC
RBR 111 A-230VAC/DC

1SNA645514R2100
1SNA645515R2200
1SNA645516R2300
1SNA645517R2400

Relay mod. 1 NO high level w/
safety switch 6 mm spacing

RBR 111 AI-24VAC/DC

1SNA645563R0200

Relay mod. 1 NO high level w/
contact protection 12 mm spacing

RBR 111 AR-24VAC/DC

1SNA645518R0500

Relay mod. 1 NC high level w/contact protection 12 mm spacing

RBR 101 AR-24VAC/DC

1SNA645519R0600

RB 121-5VDC
RB 121-12VDC
RB 121-24VDC
RB 121 A-24VAC/DC
RB 121 A-48-60VAC/DC
RB 121 A-115VAC/DC
RB 121 A-230VAC/DC
RB 121-5VDC
RB 121-12VDC
RB 121-24VDC
RB 121 A-24VAC/DC
RB 121 A-48-60VAC/DC
RB 121 A-115VAC/DC
RB 121 A-230VAC/DC
RB 121-5VDC
RB 121-12VDC
RB 121-24VDC
RB 121 A-24VAC/DC
RB 121 A-48-60VAC/DC
RB 121 A-115VAC/DC
RB 121 A-230VAC/DC
RB 121-5VDC
RB 121-12VDC
RB 121-24VDC
RB 121 A-24VAC/DC
RB 121 A-48-60VAC/DC
RB 121 A-115VAC/DC
RB 121 A-230VAC/DC

1SNA645034R2300
1SNA645069R0100
1SNA645064R0100
1SNA645001R0300
1SNA645002R0400
1SNA645003R0500
1SNA645004R0400
1SNA645534R2500
1SNA645569R0000
1SNA645564R0300
1SNA645501R0500
1SNA645502R0600
1SNA645503R0700
1SNA645504R0000
1SNA645036R2500
1SNA645037R2600
1SNA645065R0200
1SNA645005R0700
1SNA645006R0000
1SNA645007R0100
1SNA645008R1200
1SNA645536R2700
1SNA645537R2000
1SNA645565R0400
1SNA645505R0100
1SNA645506R0200
1SNA645507R0300
1SNA645508R1400

Relay module 1 SPDT high level

Relay module 1 SPDT high level

Relay module 1 SPDT low level

Relay module 1 SPDT low level

5/53 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Price

Pkg Weight
qty (1 pce)
kg (lb)

10

0.02
(0.44)

5

0.03
(0.44)

10

0.02
(0.44)

5

0.03
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

Interface relays R600 range
Ordering details
R600 Relay

R600

Type

Relay mod. 1SPDT high level w/
leakage current protec.

RB 121 AR-115VAC/DC

1SNA645046R0700

RB 121 AR-230VAC/DC

1SNA645011R2400

Relay mod. 1SPDT high level w/
large coil voltage range

RB 121 A 60-230VAC/DC

1SNA645020R0100

Relay mod. 1SPDT high level
with switch

RB 121 AI-24VAC/DC

1SNA645032R2100

Relay mod. 1SPDT high level
with safety switch

RB 121 AI-24VAC/DC

1SNA645009R1300

Relay module 1SPDT low level
with switch

RB 121 AI-24VAC/DC

1SNA645033R2200

Relay module 1SPDT low level
with safety switch

RB 121 AI-24VAC/DC

1SNA645010R0700

Relay mod. 1SPDT high level w/
leakage current protec.

RB 121 AR-115VAC/DC

1SNA645546R0100

RB 121 AR-230VAC/DC

1SNA645511R2600

Relay mod. 1SPDT high level w/
large coil voltage range
Relay mod. 1SPDT high level
with switch
Relay mod. 1SPDT high level
with safety switch
Relay module 1SPDT low level
with switch
Relay module 1SPDT low level
with safety switch

RB 121 A 60-230VAC/DC

1SNA645520R0300

RB 121 AI-24VAC/DC

1SNA645532R2300

RB 121 AI-24VAC/DC

1SNA645509R1500

RB 121 AI-24VAC/DC

1SNA645533R2400

RB 121 AI-24VAC/DC

1SNA645510R0100

RB 122 A-24VAC/DC

1SNA645012R2500

RB 122 A-48-60VAC/DC

1SNA645040R1500

RB 122 A-115VAC/DC

1SNA645041R0200

RB 122 A-230VAC/DC

1SNA645013R2600

RBR 122 A-24VAC/DC

1SNA645512R2700

Relay module 1 DPDT low level

Relay module 1 DPDT low level

D 4/12-3...

FC2

5

5

0.03
(0.066)

0.03
(0.066)

RBR 122 A-48-60VAC/DC 1SNA645540R1700
1SNA645541R0400
1SNA645513R2000

Type

Order code

BADH V0

1SNA116900R2700

50

BADL V0

1SNA399903R0200

50

BAM2 V0

1SNA399967R0100

50

Seperator end section

SC 612

1SNA290474R0200

10

Divisible shunt 10 poles

BJ 612-10

1SNA290488R0100

10

Divisible shunt 20 poles

BJ 612-20

1SNA206754R0000

10

Screw clamp distribution block sp. 12 mm D4/12-3-3

1SNA645031R2000

5

Spring clamp distribution block sp. 12 mm D4/12-3R-3R

1SNA645531R2200

5

Test plug DIA. 2 mm

FC2

1SNA645531R2200

10

Marking method

RC65 / RC610

see marking

End section

SC612

Pkg Weight
qty (1 pce)
kg (lb)

RBR 122 A-230VAC/DC

BADH

BJ...

Price

RBR 122 A-115VAC/DC

Accessories R600

BADL

Order code

Price

Pkg Weight
qty (1 pce)
kg (lb)

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/54

5

Interface relays R600 range
Connection diagrams
A1-A2	 Control supply voltage
S1	
Connection for jumper bar (input side)
S2	
Connection for jumper bar (output side)

13

13

12

A1

S2

11

RB/RBR 101 AR

A1

A2
S1

S2

2CDC 292 031 F0013

A2
S1

2CDC 292 030 F0013

A1

14

RB/RBR 111 A - 24 V AC/DC

A2
S1

S2

14

2CDC 292 033 F0013

11-12	 n/c contact			
13-14	 n/o contact			
11-12/14	
1st c/o contact		
21-22/24	
2nd c/o contact

RB/RBR 111 A - 48/60/115/230 V AC/DC

5
13

13

RB/RBR 111 AI

14

RB/RBR 111 AR

12 14

RB/RBR 121
- 12/24 V DC, only discontinued versions:
1SNA645069R0000
1SNA645064R0100, 1SNA645564R0300
1SNA645065R0200, 1SNA645565R0400

A1

A2
S1

S2

RB/RBR 121 A - 48/60/115/230 V AC/DC

A2
S1

A1

11

S2

2CDC 292 043 F0013

A2
S1

11

RB/RBR 122 A - 115/230 V AC/DC

5/55 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

21

2CDC 292 044 F0013

A1

21

A2
S1

RB/RBR 121 AR

12 14 22 24

12 14 22 24

11

12 14

auto A1
off
manu A3

RB/RBR 121 AI

A1

RB/RB 122 A - 24/48/60 V AC/DC

S2

RB/RBR 121 A
- 24 V AC/DC

2CDC 292 041 F0013

2CDC 292 040 F0013

11

11

A2
S1

12 14

A1

A2
S1

11

RB/RBR 121 (AU)
- 12/24 V DC, except:
1SNA645035R2400, 1SNA645535R2600
1SNA645037R2600, 1SNA645537R2000
see connection diagram RB...121-5VDC

12 14

S2

2CDC 292 038 F0013

2CDC 292 037 F0013

11

11

12 14

A1

A2

A2
S1

S2

RB/RBR 121
- 5 V DC, A1-A2 polarized
- 12 V DC, A1-A2 polarized, i.e. only:
1SNA645035R2400, 1SNA645535R2600
1SNA645037R2600, 1SNA645537R2000

12 14
A1

S1

S1

2CDC 292 036 F0013

S2

A2

2CDC 292 039 F0013

14

A2
S1

2CDC 292 035 F0013

S2

2CDC 292 034 F0013

A2
S1

12 14
A1

A1

S2

11

2CDC 292 042 F0013

auto A1
off
manu A3

Interface relays R600 range
Technical data
Technical data
RB 111 A

RB 111 AI

Input circuit
Rated control supply voltage Us

24 V AC/DC

Rated control supply voltage Us tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

48 V AC/DC

60 V AC/DC

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.24 W
0.34 W
0.54 W
10 mA
7 mA
9 mA
4.5 V
8V
8V
green LED V: control supply voltage applied

115 V AC/DC

0.46 W
4 mA
17 V

230 V AC/DC

24 V AC/DC

-15 %, +10 %

-15 %, +20 %

0.8 W
3.5 mA
27 V

0.24 W
10 mA
4.5 V

Output circuit
Kind of output
13-14
Rated operational voltage Ue (IEC/EN 60947-1)
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated operational current
AC12 (resistive) 230 V
(IEC/EN 60947-5-1)
AC15 (inductive) 230 V
AC15 (inductive) 120 V
DC12 (resistive) 24 V
DC13 (inductive) 24 V
DC13 (inductive) 120 V
DC13 (inductive) 230 V
AC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC15
Response time
Release time

Dimensions and weight
Weight
Dimension

relay, 1 n/o contact
250 V AC
12 V
250 V AC
10 mA
6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

5

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
5 ms
8 ms
8 ms

5 ms
8 ms

RB 111 A / RB 111 AI high level

6 ms
15 ms

7 ms
15 ms

5 ms
8 ms

RBR 111 A / RBR 111 AI high level

net weight 0.02 kg (0.044 lb)
product dimension 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)
packaging dimension

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/56

Interface relays R600 range
Technical data
Technical data
RB... 111AR high level

RB... 101AR high level

Input circuit
Rated control supply voltage Us

24 V AC/DC

Rated control supply voltage Us tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.24 W
10 mA
4.5 V
green LED V: control supply voltage applied

Output circuit
Kind of output

5

11-12 13-14 relay, 1 n/o contact
Rated operational voltage Ue (IEC/EN 60947-1)
250 V AC
Minimum switching voltage
12 V
Maximum switching voltage
250 V AC
Minimum switching current
10 mA
Rated operational current
AC12 (resistive) 230 V 6 A
(IEC/EN 60947-5-1)
AC15 (inductive) 230 V 1.5 A
AC15 (inductive) 120 V 3 A
DC12 (resistive) 24 V 6 A
DC13 (inductive) 24 V 1 A
DC13 (inductive) 120 V 0.2 A
DC13 (inductive) 230 V 0.1 A
AC rating
Utilization category (pilot duty) B300
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty) R300
(UL 508;
NEMA ICS-5)
Minimum switching power
0.6 W / 0.6 VA
Mechanical lifetime
1 x 107 switching cycles
Electrical lifetime
at AC15 1 x 10 5 switching cycles
Response time
5 ms
Release time
8 ms

Dimensions and weight
Weight
Dimension

RB 111AR / RB 101AR high level
net weight 0.03 kg (0.066 lb)
product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in)
packaging dimension

5/57 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

relay, 1 n/c contact
-

RBR 111A / RBR 111AR high level
12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)

Interface relays R600 range
Technical data
Technical data
RB... 121 / RB... 121A high level
Input circuit
Rated control supply voltage Us

5 V DC

Rated control supply voltage Us tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

12 V DC

DC -15 %, +20 %
AC 0.2 W
0.2 W
40 mA
16 mA
1.2 V
2.2 V
green LED V: control supply voltage

24 V AC/DC

48 V AC/DC

60 V AC/DC

115 V AC/DC

230 V AC/DC
-15 %, +10 %

-/+ 10 %
50/60 Hz
0.24 W
10 mA
4.5 V
applied

0.33 W
7 mA
8V

0.54 W
9 mA
8V

0.46 W
4 mA
17 V

0.8 W
3.5 mA
27 V

Output circuit
Kind of output
11-12/14
Rated operational voltage Ue (IEC/EN 60947-1)
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated operational current
AC12 (resistive) 230 V
(IEC/EN 60947-5-1)
AC15 (inductive) 230 V
AC15 (inductive) 120 V
DC12 (resistive) 24 V
DC13 (inductive) 24 V
DC13 (inductive) 120 V
DC13 (inductive) 230 V
AC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC15
Response time
Release time

Dimensions and weight
Weight
Dimension

relay, 1 c/o (SPDT) contact
250 V AC
12 V
250 V AC
10 mA
6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

5

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
5 ms
8 ms

5 ms

RB 121 / RB 121A high level
net weight 0.02 kg (0.044 lb)
product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in)
packaging dimension

5 ms

5 ms

6 ms
15 ms

7 ms
16 ms

RBR 122 / RBR 122A high level
6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/58

Interface relays R600 range
Technical data
Technical data
RB... 121 / RB... 121A low level
Input circuit
Rated control supply voltage Us

5 V DC

Rated control supply voltage Us tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

12 V DC

DC -15 %, +20 %
AC 0.2 W
0.2 W
40 mA
16 mA
1.2 V
2.2 V
green LED V: control supply voltage

24 V AC/DC

48 V AC/DC

60 V AC/DC

115 V AC/DC

230 V AC/DC
-15 %, +10 %

-/+ 10 %
50/60 Hz
0.24 W
10 mA
4.5 V
applied

0.33 W
7 mA
8V

0.54 W
9 mA
8V

0.46 W
4 mA
17 V

0.8 W
3.5 mA
27 V

5 ms

5 ms

6 ms
15 ms

7 ms
16 ms

Output circuit

5

Kind of output
11-12/14
Rated operational voltage Ue (IEC/EN 60947-1)
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated operational current
AC12 (resistive) 230 V
(IEC/EN 60947-5-1)
AC15 (inductive) 230 V
AC15 (inductive) 120 V
DC12 (resistive) 24 V
DC13 (inductive) 24 V
DC13 (inductive) 120 V
DC13 (inductive) 230 V
AC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC15
Response time
Release time

Dimensions and weight
Weight
Dimension

relay, 1 c/o (SPDT) contact
250 V AC
5V
250 V AC
1 mA
6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300
R300
0.05 W / 0.05 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
5 ms
5 ms
8 ms

5 ms

RB 121 / RB 121A low level
net weight 0.02 kg (0.044 lb)
product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in)
packaging dimension

5/59 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

RBR 122 / RBR 122A low level
6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in)

Interface relays R600 range
Technical data
Technical data
RB... 121AR / RB... 121AI low level

RB... 121AI low level

Input circuit
Rated control supply voltage Us

115 V AC/DC

Rated control supply voltage Us tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out voltage
Indication of operational states

230 V AC/DC

24 V AC/DC

DC -20%, +15%
-10%, +15%
AC -/+ 10 %
50/60 Hz
2W
2.8 W
18 mA
12 mA
17 V
27 V
green LED V: control supply voltage applied

24 V AC/DC

-20%, +15%
0.24 W
10 mA
4.5 V

0.24 W
10 mA

Output circuit
Kind of output
11-12/14
Rated operational voltage Ue (IEC/EN 60947-1)
Minimum switching voltage
Maximum switching voltage
Minimum switching current
Rated operational current
AC12 (resistive) 230 V
(IEC/EN 60947-5-1)
AC15 (inductive) 230 V
AC15 (inductive) 120 V
DC12 (resistive) 24 V
DC13 (inductive) 24 V
DC13 (inductive) 120 V
DC13 (inductive) 230 V
AC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
DC rating
Utilization category (pilot duty)
(UL 508;
NEMA ICS-5)
Minimum switching power
Mechanical lifetime
Electrical lifetime
at AC15
Response time
Release time

Dimensions and weight
Weight
Dimension

relay, 1 c/o (SPDT) contact
250 V AC
12 V
250 V AC
10 mA
6A
1.5 A
3A
6A
1A
0.2 A
0.1 A
B300

5V
1 mA

5

R300
0.6 W / 0.6 VA
1 x 107 switching cycles
1 x 10 5 switching cycles
6 ms
15 ms

0.05 W / 0.05 VA
7 ms
16 ms

5 ms
8 ms

RB 121AR/RB 121AI low/high level
net weight 0.03 kg (0.066 lb)
product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in)
packaging dimension

5 ms
8 ms

RB 121AR/RBR 121AI low/high level
12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)

Technical data
RB... 122A low level
Input circuit
Rated control supply voltage Us

24 V AC/DC

Rated control supply voltage Us tolerance
Rated frequency
Typical power consumption
Typical current
Drop-out
Indication of operational states

48 V AC/DC

DC -15 %, +20 %
AC -/+ 10 %
50/60 Hz
0.48 W
0.62 W
20 mA
13 mA
5.4 V
8.8 V
green LED V: control supply voltage applied

60 V AC/DC

115 V AC/DC

230 V AC/DC
-15 %, +10 %

0.96 W
16 mA
8.8 V V

0.58 W
5 mA
20 V

1.15 W
5 mA
10 V

6 ms
15 ms

6 ms
15 ms

Output circuit
Kind of output

11-12/14 relay, 1st c/o (SPDT) contact
21-22/24 relay, 2nd c/o (SPDT) contact
Rated operational voltage Ue (IEC/EN 60947-1)
250 V AC
Minimum switching voltage
5V
Maximum switching voltage
250 V DC - 250 V AC
Minimum switching current
1 mA
AC12 (resistive) 230 V 8 A
Rated operational current
(IEC/EN 60947-5-1)
Minimum switching power
5 mW / 5 mVA
Mechanical lifetime
2 x 107 switching cycles
Electrical lifetime
at AC15 1 x 10 5 switching cycles
Response time
6 ms
10 ms
Release time
10 ms
14 ms

Dimensions and weight
Weight
Dimension

RB 122A low level
net weight 0.03 kg (0.066 lb)
product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in)
packaging dimension

5A

10 ms
14 ms

RBR 122A low level
12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in)

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/60

Interface relays R600 range
General technical data
Technical data
RB

RBR

Screw terminal

Spring-type terminal

General data
Material of housing
Degree of protection

UL 94 V0
housing / IP20 NEMA1
terminals

Electrical connection
Wire size
Stripping length
Tightening torque

fine-stranded 0.22-2.5 mm² (24-14 AWG)
rigid 0.2-4 mm² (24-12 AWG)
9 mm / 0.354 in
0.4-0.6 Nm (3.5-5.3 lb.in)

0.2-2.5 mm² (24-14 AWG)

Environmental data
Ambient temperature ranges

storage -40...+80 °C
operation -20...+70 °C

Isolation data

5

Rated insulation voltage Ui (IEC/EN 60950-1, EN 50178)
Rated impulse withstand voltage
input / output
Uimp (EN 50178)
shock coil / output
output / output

4000 V RMS
4000 V RMS (RB122A: 3800 V RMS, RB111AR: 3500 V RMS)
4000 V RMS
1000 V RMS

5/61 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Interface relays R600 range
Dimensional drawings, Load limit curves
All interface relays of R600 range

center of rail

center of rail

Spring clamp module

Screw clamp module

5

Load limit curves
RB 111 A, RB 111 AI, RB 111 AR, RB 101 AR,
RB 121 AR, RB 121 AI, RB 121 AI (gold plated), RB 121 AI
RB 121 (gold plated), RB 121 A (gold plated), RB 121, RB 121 A
Limited load in CC

Load limit curve RB ... 122A (gold plated)

Voltage [V]

Voltage (Vcc)

Max. DC load breaking capacity

resistive
load

Current (Acc)

24 V
110/120 V
220/230 V

DC12

AC12

DC13

AC15

6A
0,3 A
0.2 A

6A
6A
6A

1
0.2 A
0.1 A

3A
3A
3A

Current [A]

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/62

Optocouplers R600 range
Product group picture

5

5/63 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Optocouplers R600 range
Table of contents
Optocouplers R600 range
Product group picture	

5/63

Table of contents	

5/64

Selection	

5/65

Ordering details	

5/67

Connection diagrams	

5/68

Technical data	

5/69

5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/64

Order number
1SNA 645 047 R0000
1SNA 645 547 R0200
1SNA 645 021 R2600
1SNA 645 521 R2000
1SNA 645 049 R1200
1SNA 645 549 R1400
1SNA 645 022 R2700

1SNA 645 550 R1100
1SNA 645 051 R0400
1SNA 645 025 R2200
1SNA 645 024 R2100
1SNA 645 551 R0600
1SNA 645 525 R2400
1SNA 645 524 R2300
1SNA 645 053 R0600
1SNA 645 553 R0000
1SNA 645 054 R0700
1SNA 645 058 R1300
1SNA 645 554 R0100
1SNA 645 558 R1500
1SNA 645 026 R2300
1SNA 645 059 R1400
1SNA 645 526 R2500
1SNA 645 559 R1600
1SNA 645 027 R2400
1SNA 645 029 R0600
1SNA 645 527 R2600
1SNA 645 529 R0000

OBRIC 0100 5-12VDC
OBIC 0100 24VDC
OBRIC 0100 24VDC
OBIC 0100 48-60VAC/DC
OBRIC 0100 48-60VAC/DC
OBIC 0100 115-230VAC/DC

OBRIC 0100 115-230VAC/DC 1SNA 645 522 R2100
1SNA 645 050 R1700

OBIC 0100 5-12VDC

OBOC 1000-5-12VDC
OBROC 1000-5-12VDC
OBOC 1000-24VDC
OBOC 1500-24VAC/DC
OBOC 5000-24VDC
OBROC 1000-24VDC
OBROC 1500-24VAC/DC
OBROC 5000-24VDC
OBOC 1000-48-60VAC/DC
OBROC 1000-48-60VAC/DC
OBOC 1000-115VAC/DC
OBOC 5000-115VAC/DC
OBROC 1000-115VAC/DC
OBROC 5000-115VAC/DC
OBOC 1000-230VAC/DC
OBOC 5000-230VAC/DC
OBROC 1000-230VAC/DC
OBROC 5000-230VAC/DC
OBOA 1000-24VDC
OBOA 2000-24VDC
OBROA 1000-24VDC
OBROA 2000-24VDC

5

Type

Optocouplers R600 range
Selection

Input voltage

5 - 12 V DC 	
	
	
	
	
n	
n	
	
	
	
	
	
	
n	
n

24 V DC 	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
n	
n	
n	
n	
n	
n	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n

48 - 60 V DC 	
	
	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
	
	
	
	
	
	
	

115 - 230 V DC 	
	
	
	
	
	
	
	
	
	
	
n	
n

115 V DC 	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
	
	
	
	
	
	
	
	
	

230 V DC 	
	
	
	
	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
	
	
	
	
	

24 V AC 	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
	
	
n

48 - 60 V AC 	
	
	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
	
	
	
	
n	
n	
	
	
	
	
	
	
	
	
	
	
	
	
	

115-230 V AC 	
	
	
	
	
	
	
	
	
	
	
n	
n

115 V AC 	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
	
	
	
	
	
	
	
	
	

230 V AC 	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
	
	
	
	
	

Output rating

100 mA 	
	
	
	
	
n	
n	
n	
n	
n	
n	
n	
n

2A	
	
	
	
	
	
	
	
	
	
	
	
	
n	
n	
n	
n	
	
n	
n	
	
n	
n	
n	
	
n	
	
n	
	
n	
	
	
n	
	
n

5A	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
n	
	
	
n	
	
	
	
n	
	
n	
	
n	
	
n

1A	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

Output voltage
	
n	
	
n	
	
	

58 V DC 	

	

	

	

	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n	

n

400 V AC 	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

	

Terminal type

	

n	

n	

n	

n	

	

Screw 	

	

	

	

	

n	

	

n	

	

n	

	

n	

	

n	

	

n	

n	

n	

	

	

	

n	

	

n	

n	

	

	

n	

n	

	

	

n	

n	

	

	

	

Spring 	

	

	

	

	

	

n	

	

n	

	

n	

	

n	

	

n	

	

	

	

n	

n	

n	

	

n	

	

	

n	

n	

	

	

n	

n	

	

	

n	

n	

	

5/65 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

	
	
	
n	
n

	
	
	
	
	

	
n	
n

1SNA 645 528 R0700

1SNA 645 562 R0100

OBROA 1000-115VAC/DC

n

1SNA 645 028 R0500

1SNA 645 062 R0700

OBOA 1000-115VAC/DC

n	

OBROA 1000-230VAC/DC

1SNA 645 561 R0000

OBROA 1000-48-60VAC/DC

	

OBOA 1000-230VAC/DC

1SNA 645 061 R0600

OBOA 1000-48-60VAC/DC

Optocouplers R600 range
Selection

n	
n

	
	
	
n	
n

	
	
	
	
	
n	
n

	
n	
n	
n	
n	
n	
n

	

n	

n	

n	

n	

n	

n

	

n	

	

n	

	

n

	

	

n	

	

n	

	

5

n

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/66

Optocouplers R600 range
Ordering details
R600 Optocoupler

Optocoupler module 100 mA/DC

Type

Order code

OBIC 0100-5-12VDC

1SNA645047R0000

OBIC 0100-24VDC

1SNA645021R2600

Price

OBIC 0100-48-60VAC/DC 1SNA645049R1200

Pkg Weight
qty (1 pce)
kg (lb)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.02
(0.44)

10

0.03
(0.066)

5

0.03
(0.066)

10

0.03
(0.066)

5

0.03
(0.066)

2CDC 291 001 F0013

OBIC 0100-115-230VAC/DC 1SNA645022R2700

Optocoupler module 100 mA/DC

5

Optocoupler module 2 A/DC

Optocoupler module 5 A/DC

Optocoupler module 5 A/DC

Optocoupler module 1 A/AC 6
mm spacing
Optocoupler module 2 A/AC 12
mm spacing
Optocoupler module 1 A/AC 6
mm spacing
Optocoupler module 2 A/AC 12
mm spacing

Accessories

SC612
FC2

OBOC 1000-5-12VDC

1SNA645050R1700

OBOC 1000-24VDC

1SNA645051R0400

OBOC 1500-24VAC/DC

1SNA645025R2200

OBOC 1000-48-60VAC/DC

1SNA645053R0600

OBOC 1000-115VAC/DC

1SNA645054R0700

OBOC 1000-230VAC/DC

1SNA645026R2300

OBROC 1000-5-12VDC

1SNA645550R1100

OBROC 1000-24VDC

1SNA645551R0600

OBROC 1500-24VAC/DC

1SNA645525R2400

OBROC 1000-48-60VAC/DC 1SNA645553R0000
OBROC 1000-115VAC/DC

1SNA645554R0100

OBROC 1000-230VAC/DC
OBOC 5000-24VDC
OBOC 5000-115VAC/DC

1SNA645526R2500
1SNA645024R2100
1SNA645058R1300

OBOC 5000-230VAC/DC

1SNA645059R1400

OBROC 5000-24VDC

1SNA645524R2300

OBROC 5000-115VAC/DC

1SNA645558R1500

OBROC 5000-230VAC/DC

1SNA645559R1600

OBOA 1000-24VDC

1SNA645027R2400

OBOA 1000-48-60VAC/DC 1SNA645061R0600
OBOA 1000-115VAC/DC

1SNA645062R0700

OBOA 1000-230VAC/DC

1SNA645028R0500

OBOA 2000-24VDC

1SNA645029R0600

OBROA 1000-24VDC

1SNA645527R2600

OBROA 1000-48-60VAC/DC 1SNA645561R0000
OBROA 1000-115VAC/DC 1SNA645562R0100
OBROA 1000-230VAC/DC

1SNA645528R0700

OBROA 2000-24VDC

1SNA645529R0000

Order code

BADH V0

1SNA116900R2700

50

BADL V0

1SNA399903R0200

50

BAM2 V0

1SNA399967R0100

50

Seperator end section

SC 612

1SNA290474R0200

10

Divisible shunt 10 poles

BJ 612-10

1SNA290488R0100

10

Divisible shunt 20 poles

BJ 612-20

1SNA206754R0000

10

Screw clamp distribution block sp. 12 mm D4/12-3-3

1SNA645031R2000

5

Spring clamp distribution block sp. 12 mm D4/12-3R-3R

1SNA645531R2200

5

Test plug DIA. 2 mm

FC2

1SNA645531R2200

10

Marking method

RC65 / RC610

see marking

End section

D 4/12-3...

1SNA645521R2000

OBRIC 0100-48-60VAC/DC 1SNA645549R1400

Type

BADH

BJ...

1SNA645547R0200

OBRIC 0100-24VDC

OBRIC 0100-115-230VAC/DC 1SNA645522R2100

Optocoupler module 2 A/DC

BADL

OBRIC 0100-5-12VDC

5/67 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Price

Pkg Weight
qty (1 pce)
kg (lb)

Optocouplers R600 range
Connection diagrams

OB...IC 0100 - 5-12 V DC
115-230 V AC/DC

OB...IC 0100
24 V DC
24-48-60 V AC/DC

OB...OC 1000 - 5-12 V DC

5
OB...OC 1500 - 24 V AC/DC
OB...OC 1000
24 V DC
48-60-115-230 V AC/DC

OB...OC 5000
24 V DC
24-48-60-115-230 V AC/DC

OB...OA 1000
24 V DC
48-60-115-230 V AC/DC
OB...OA 2000 - 24 V DC

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/68

Optocouplers R600 range
Technical data
Technical data
Optocoupler : 5 to 58 V DC output / 100 mA - 6 mm 0.236“ spacing
OB...IC 0100
Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC

5 V DC - 12 V DC

24 V DC

48 V AC/DC

Frequency

5

Input current AC/DC

5 mA

Pull-in voltage at Is=100%

4V

Switching time C / O

10 µs / 500 µs

Operating frequency

9 mA

115 V AC/DC

230 V AC/DC

5 mA

7 mA /
16 mA

11.5 mA /
25 mA

1000 Hz

4 mA

4 mA

15 V

25 V

60 V AC / 70 V DC

5 ms / 20 ms

5 ms / 15 ms

Permissible leakage current

20 Hz

Output

0.9 mA

Output voltage

4.5 to 58 V DC

Output current min.

1 mA

Output current max.

100 mA

Output leakage current at Umax.
Redidual voltage at I max and U rated

60 V AC/DC

50 / 60 Hz

1 mA

0.9 mA

1.6 mA

< 50 µA
typical 1 V
max 1.3 V

Frequency on inductive load
Isolation Input / Output
Temperature

input / Output 2500 V RMS
storage -40...+80 °C
operating -20...+70 °C

1)

Other characteristics
Body material
Wire size

Screw clamp
Solid wire 0.2 - 4 mm² (24-12 AWG)

0.2-2.5 mm² (24-12 AWG)

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending for 12 V DC) ,

Reference standards
1)

Spring clamp

grey UL 94 V0

(pending),

, LRS ,

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.

Dimensional drawings

center of rail

Screw clamp module

center of rail

Spring clamp module

5/69 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Optocouplers R600 range
Technical data
Technical data
Optocoupler : 5 to 58 V DC output / 2 A - 6 mm 0.236“ spacing
OB..OC

OB...OC 0100

OB...OC 1000

1500

Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC

5 V DC - 12 V DC

24 V DC

Frequency

V AC/
24 V AC/DC 48 V AC/DC 60 V AC/DC 115
DC

230 V AC/
DC

50 / 60 Hz

Input current

5 mA

Pull-in voltage at Is=100%

9 mA

4 mA

6.3 mA

4 mA

4V

15 V

15 V

27 V

Switching time C / O

15 µs / 250 µs

30 µs /
400 µs

1 ms / 7 ms 5 ms / 20 ms

Operating frequency

2000 Hz

1000 Hz

60 Hz

20 Hz

Permissible leakage current

1 mA

0.8 mA

0.9 mA

1 mA

5.1 mA

4.2 mA

4 mA

50 V

80 V

500 µs /
10 ms

1 ms /
15 ms

5

0.3 mA

Output
Output voltage

4.5 to 58 V DC

Output current min.

1 mA

Output current max.

2A

Output leakage current at Umax.
Redidual voltage at I max and U rated

< 50 µA
typical 0.1 V
max 0.5 V

Frequency on inductive load
Isolation Input / Output
Temperature

input / Output 2500 V RMS
storage -40...+80 °C
operating -20...+70 °C

1)

Other characteristics
Body material
Wire size

Screw clamp
Solid wire 0.2 - 4 mm² (24-12 AWG)

0.2-2.5 mm² (24-12 AWG)

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending for 12 V DC) ,

Reference standards
1)

Spring clamp

grey UL 94 V0

(pending),

, LRS ,

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.

Dimensional drawings

center of rail

Screw clamp module

center of rail

Spring clamp module

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/70

Optocouplers R600 range
Technical data
Technical data
Optocoupler : 5 to 58 V DC output / 5 A - 6 mm 0.236“ spacing
OB... OC 5000
Input
Input voltage

24 V DC

Frequency

5

115 V AC/DC

230 V AC/DC

50 / 60 Hz

50 / 60 Hz

Input current

5.4 mA

4.2 mA

4 mA

Pull-in voltage at Is=100%

12 V

50 V

80 V

Switching time C / O

30 µs / 400 µs

500 µs / 10 ms

1ms / 15 ms

Operating frequency

1000 Hz

50 Hz

35 Hz

Permissible leakage current

0.8 mA

0.3 mA

0.3 mA

Output
Output voltage

4.5- 58 V DC

Output current min.

25 mA

Output current max.

5A

Output leakage current at Umax.
Redidual voltage at I max and U rated

< 0.50 mA
typical 1 V
max 1.6 V

Frequency on inductive load
Isolation Input / Output

See Note 1
input / Output 2500 V RMS

Temperature
Ambient temperature

storage -40...+80 °C
operating See derating curve

Other characteristics
Body material
Wire size

grey UL 94 V0
Solid wire 0.2 - 4 mm² (24-12 AWG)
Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

10 mm (0.394 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending),

Reference standards

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Dimensional drawings

center of rail

Screw clamp module

center of rail

Spring clamp module

5/71 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

Optocouplers R600 range
Technical data
Technical data
Optocoupler : 24 to 400 V AC output / 2 A max. - 6 mm or 12 mm spacing
OB...OA

OB...OA 1000

2000

Relay characteristics coil
Input voltage: +20%, -15% on DC ; 10%, -10% on AC

24 V DC

48 V AC/DC

Frequency

60 V AC/DC

115 V AC/DC

230 V AC/DC

24 V DC

3.6 mA

50/60 Hz

Input current

3.6 mA

4.3 mA

5.5 mA

4.15 mA

4.6 mA

Pull-in voltage at Is=100%

14 V

15 V

18 V

60 V

135 V

14 V

Switching time C / O

150 µs / 1 ms

3 ms / 30 ms

2.2 ms / 18 ms

2.5 ms / 25 ms

150 µs /
1 ms

Operating frequency

500 Hz

20 Hz

25 Hz

20 Hz

500 Hz

Permissible leakage current

1 mA

5

Output
Output voltage

24-400 V AC

Frequency

50/60 Hz

Output current min.

25 mA

Output current max.

1A

Output leakage current at Umax.

< 0.50 mA

Redidual voltage at I max and U rated

2A

typical 1 V
max 1.6 V

Frequency on inductive load
Isolation Input / Output
Temperature

input / Output 2500 V RMS
storage -40...+80 °C
operating -20...+70 °C

1)

Other characteristics
Body material
Wire size

Screw clamp
Solid wire 0.2 - 4 mm² (24-12 AWG)

0.2-2.5 mm² (24-12 AWG)

Stranded wire 0.22 - 2.5 mm² (24-12 AWG)

Rated wire size

2.5 mm² (12 AWG)

Wire stripping length

9 mm (0.354 in)

Recommended screwdriver

3.5 mm (0.137 in)

Protection

IP20 NEMA1

Recommended torque

0.4-0.6 Nm (3.5-5.3 lb.in)

Approvals

(pending for 12 V DC) ,

Reference standards
1)

Spring clamp

grey UL 94 V0

(pending),

, LRS ,

CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6.

Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased.

Dimensional drawings

center of rail

Screw clamp module

center of rail

Spring clamp module

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/72

Terminal blocks 	
component holder

D 2,5/5-MP

	

Spacing 5,08 mm (.200")

1

DIN 3	

D 2,5/5-MP...

Spacing 5,08 mm (.200")

Base for pluggable plug	
R500 Series	
	

D 2,5/5-MP1

Spacing 5,08 mm (.200")

1
4

2

4

2

2

5

5

3

5

3

3

6

End stop	
	 th. 9 mm	
BADL	V0	
					
1SNA 399 903 R0200
	 th. 9,1 mm	 BAM	V2	
End stop	
					
1SNA 103 002 R2600
	 th. 9,1 mm	 BAM V0	V0	
End stop	
					
1SNA 199 306 R0300
	 35 x 7,5 x 1	 PR3.Z2		
Rail	
					
1SNA 174 300 R1700
	 35 x 15 x 2,3	 PR4		
Rail	
					
1SNA 168 500 R1200
	 35 x 15 x 1,5	 PR5	
Rail	
					
1SNA 168 700 R2200

1
4

6

6

center of rail

center of rail

Relay/opto. base without output LED

center of rail

Relay/opto. base without input LED

Relay/opto. base with output LED

Observations
Terminal blocks are delivered without plugs.

Type 	
Grey V0

Max. working temperature		
	
version without LED 	 : 100°C	
	
version with LED 	
: 85°C
Contact resistance	
: < 5 mΩ

Part numbers

Type 	
Grey V0

Order plugs separately

D	 2,5/5-MP

Part numbers

	D 2,5/5-MP1

1SNA607224R0100

Type 	
Grey V0

Order plugs separately

1SNA607223R0000

Part numbers
Order plugs separately

	 2,5/5-MP-24VDC		
D

1SNA607222R0700

	 2,5/5-MP-24VAC/DC
D

1SNA607260R2100	

	
1SNA607261R1600
D
2,5/5-MP-48VAC/DC
	 2,5/5-MP-110VAC
D

5

1SNA607266R1300

	1SNA607267R1400
D
2,5/5-MP-230VAC	

Characteristics
Wire size
Voltage

IEC		UL/CSA

	
Compression	
clamp	
Rated
Pulse
Pollution degree
Rated
Rated / Gauge

Current
Wire size
Wire stripping length
Recommended screwdriver
Recommended torque
Protection

pending

Solid wire 	
0,2-4 mm²		
24-12 AWG		
Stranded wire 	
0,22-2,5 mm²		
24-12 AWG
	
320 V		
300 V
	
4 kV
	3
	
6 A		
6A
	
2,5 mm²		
12 AWG
		
10 mm / .394"
		
3,5 mm / .137"
		0,4-0,6 Nm / 3,5-5,3 lb.in
		
IP 20 / NEMA1

Accessories
	
1	 Test device
	
2	 Test plug
1
	3	
Relay plug	
1 SPDT 10 mA/6 A
			
1 SPDT 1 mA/6 A
	
4	 Input optocoupler plug	 5 V DC
			
24 V DC
			
24 V DC
2
			
48 V DC
			
125 V DC
			
24 V AC
			
48 V AC
			
115 V AC
			
230 V AC
	
5	 Output optocoupler 	24 V DC/100 mA
		
plug	
24 V DC/100 mA
3, 4, 5, 6,
			
24 V DC/2 A
7, 8, 9
			
24 V DC/2 A
			
24 V DC/1 A
			
24 V DC/1 A
			
24 V DC/1 A
	
5	 Output optocoupler 	 5 V DC/100 mA
		 plug	
5 V DC/100 mA
			
48 V DC/100 mA
			
48 V DC/100 mA
10
			
5 V DC/2 A
			
5 V DC/2 A
			
5 V DC/1 A
			
5 V DC/1 A
	
7	 Fuse plug 	
125 V/125 mA
			
125 V/500 mA
			
125 V/2 A
			
125 V/5 A
			
250 V/125 mA
			
250 V/2 A
			
250 V/5 A
			
125 V/125 mA
			
250 V/125 mA
			
125 V/2 A
	
8	 Strap plug	
	
9	 Converter plug 	
0-20 mA/0-10 V
			
4-20 mA/2-10 V
			
0-20 mA/0-5 V
			
4-20 mA/1-5 V
	
10	 Comb type jumper bar	
10 poles
R
	R	
See section on marking

Type 	
	blue
DCB	
(1)		
	
DIA. 2
FC2			
	beige
BNMS
R24V-1
	beige
BNMS
R24V-2

Type 	

1SNA031807R1400
1SNA031810R1200
1SNA031813R0100
1SNA031815R0300
1SNA031817R0500
1SNA031819R1700
1SNA031839R1300
1SNA031806R1300
1SNA031809R2600
1SNA031808R2500
1SNA031811R0700
1SNA031812R0000
1SNA031814R0200
1SNA031816R0400
1SNA031818R1600
1SNA031821R0100
1SNA031838R1200
1SNA031822R0200
1SNA031823R0300
1SNA031824R0400
1SNA031825R0500
1SNA031826R0600
1SNA031827R0700
1SNA031828R1000
1SNA031849R2500
1SNA031829R1100
1SNA031830R1600
1SNA031832R0400
1SNA031832R0400
1SNA031833R0500
1SNA031833R0500
1SNA205523R2200

	

RC 55

BNMS F125mA-1
	grey
BNMS F500mA-1
	grey
BNMS F2A-1
	grey
BNMS F5A-1
	grey
BNMS F125mA-2
	grey
BNMS F2A-2
	grey
BNMS F5A-2
	grey
	

pending

	
0,2-4 mm²		
24-12 AWG		
	
0,22-2,5 mm²		
24-12 AWG
	
320 V		
300 V
	
4 kV
	3
	
6 A		
6A
	
2,5 mm²		
12 AWG
		
10 mm / .394"
		
3,5 mm / .137"
		0,4-0,6 Nm / 3,5-5,3 lb.in
		
IP 20 / NEMA1

1SNA031821R0100
1SNA031838R1200
1SNA031822R0200
1SNA031823R0300
1SNA031824R0400
1SNA031825R0500
1SNA031826R0600
			

	

Type 	
DCB	
(1)		
	blue
FC2			
	
DIA. 2
BNMS
R24V-1
	beige
BNMS
R24V-2
	beige

Part numbers
1SNA105028R2100
1SNA007865R2600
1SNA031820R1400
1SNA031847R1300

	

BNMS
N24V-3
	red
BNMS
P24V-3
	red
BNMS
N24V-1
	red
BNMS
P24V-1
	red
BNMS
N24V-2
	red
BNMS
P24V-2
	red
BNMS
A24V-4
	black

1SNA031807R1400
1SNA031810R1200
1SNA031813R0100
1SNA031815R0300
1SNA031817R0500
1SNA031819R1700
1SNA031839R1300

BNMS
F125mA-1
	grey
BNMS
F500mA-1
	grey
BNMS
F2A-1
	grey
BNMS
F5A-1
	grey
BNMS
F125mA-2
	grey
BNMS
F2A-2
	grey
BNMS
F5A-2
	grey
BNMS
F125mA-3
	grey
BNMS
F125mA-4
	grey

1SNA031821R0100
1SNA031838R1200
1SNA031822R0200
1SNA031823R0300
1SNA031824R0400
1SNA031825R0500
1SNA031826R0600
1SNA031827R0700
1SNA031828R1000

BNMS F2A-7
	grey

1SNA031849R2500
1SNA031829R1100
BNMS ST2
	grey
1SNA031830R1600
BNMS ST1
	grey

	PCMS
RC 55

V0	 (2)

	
1SNA205523R2200

BNMS
ST1
	grey
1SNA031829R1100

PCMS
V0	 (2)
	

(1) Solely on the top stage. (2) Comb type jumper bar from 2 to 22 poles, see accessories.

5/73 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

IEC		UL/CSA

	

Part numbers

DCB	
(1)		
	blue
			
FC2
	
DIA. 2 1SNA105028R2100
		
1SNA007865R2600
BNMS
T5V-1
	white	
1SNA031831R0300
BNMS
T24V-1
	white
1SNA031848R2400
BNMS
T24V-2
	white
1SNA031800R2100
BNMS
T48V-1
	white
1SNA031801R1600
BNMS
T125V-1
	white
1SNA031845R1100
BNMS
T24V-1
	yellow
1SNA031802R1700
BNMS
T48V-1
	yellow
1SNA031803R1000
BNMS
T115V-1
	yellow
1SNA031804R1100
BNMS
T230V-1
	yellow
1SNA031805R1200

	
	red
BNMS
N24V-3
	red
BNMS
P24V-3
	red
BNMS
N24V-1
	red
BNMS
P24V-1
	red
BNMS
N24V-2
	red
BNMS
P24V-2
	black
BNMS
A24V-4
	red
BNMS
N5V-3
	red
BNMS
P5V-3
	red
BNMS
N48V-3
	red
BNMS
P48V-3
	red
BNMS
N5V-1
	red
BNMS
P5V-1
	red
BNMS N5V-2
	red
BNMS P5V-2
	grey
BNMS
F125mA-1
	grey
BNMS
F500mA-1
	grey
BNMS
F2A-1
	grey
BNMS
F5A-1
	grey
BNMS
F125mA-2
	grey
BNMS
F2A-2
	grey
BNMS
F5A-2
	grey
BNMS
F125mA-3
	grey
BNMS
F125mA-4
	grey
BNMS
F2A-7
	grey
BNMS
ST1
	grey
BNMS
ST2
	grey
BNMS
CAI/U-500
	grey
BNMS
CAI/U-500
	grey
BNMS
CAI/U-250
	
BNMS
CAI/U-250
PCMS V0	 (2)

pending

	
0,2-4 mm²		
24-12 AWG		
	
0,22-2,5 mm²		
24-12 AWG
	
320 V		
300 V
	
4 kV
	3
	
6 A		
6A
	
2,5 mm²		
12 AWG
		
10 mm / .394"
		
3,5 mm / .137"
		0,4-0,6 Nm / 3,5-5,3 lb.in
		
IP 20 / NEMA1

Part numbers
1SNA105028R2100
1SNA007865R2600
1SNA031820R1400
1SNA031847R1300

IEC		UL/CSA

	

RC 55

			
1SNA 205523R2200

DC plugs

AC plugs

2

2

3

4

1

Derating curve

3

4

Switching time RL curve 1
for 24 V DC plugs only

1

Switching time (µs)

2CDC 292 013 F0013

Input optocoupler
plugs

Derating curve

Load resistance RL (kW)

5 V DC
Part number

24 V DC

Type	P/N

48 V DC
Type	P/N

Type	P/N

5

125 V DC
Type	P/N

	BNMS T48V-1
	BNMS T125V-1
	BNMS T5V-1
BNMS T24V-1
1SNA031831R0300
1SNA031801R1600
1SNA031845R1100
1SNA031800R2100
	BNMS T24V-2
1SNA031848R2400

Characteristics
INPUT
Voltage
Max. current
Typical triggering threshol at Is = 100%
Switching time			C/O
Leakage current

	
	
	
	
	

OUTPUT
Max. voltage. / Max. current
Residual voltage max. I and rated U standard
		
max.
Compatibility
Input / Ouput isolation

	
	
	
	
	
	

TEMPERATURE
	Storage
	Operating

	
	
	

4,5 V to 5,5 V DC
6 mA
3,5 V
20 µs / 1,3 ms

58 V / 30 mA
2,3 V DC
2,7 V DC
2,5 kV
- 30°C to + 80°C
- 20°C to + 55°C

	 BNMS T24V-1		 BNMS T24V-2	 	
		
19,2 V to 27,6 V DC
	
		
5 mA
	
		
12 V DC
	
	 20 µs / 1,3 ms		 10 µs / see curve 1 	
		
1 mA
	
	
	 58 V / 30 mA		 58 V / 5 mA
	
2,3 V DC		 0,3 V DC
	
2,7 V DC		 0,5 V DC
			TTL
		
2,5 kV
	

	
	
	
	
	
	

	
	

	
	
	

48 V AC

24 V AC
Part number

- 30°C to + 80°C
-20°C to + 55°C

58 V / 30 mA
2,3 V DC
2,7 V DC
2,5 kV
- 30°C to + 80°C
- 20°C to + 55°C

	
	
	
	
	
	
	
	
	
	
	
	
	
	

115 V AC

Type	P/N

Type	P/N

38,4 V to 55,2 V DC
4,1 mA
21 V DC
20 µs / 1,3 ms
0,8 mA

93,5 V to 140 V DC
3 mA
50 V DC
20 µs / 1,3 ms

58 V / 30 mA
2,3 V DC
2,7 V DC
2,5 kV
- 30°C to + 80°C
- 20°C to + 55°C

230 V AC
Type	P/N

Type	P/N

	BNMS T24V-1
	BNMS T48V-1
	BNMS T115V-1
	BNMS T230V-1
1SNA031802R1700
1SNA031803R1000
1SNA031804R1100
1SNA031805R1200

Charateristics
INPUT
Voltage
Max. current
Typical triggering threshold at Is = 100%
Switching time			C/O
Leakage current
OUPUT
Max. voltage / Max. current
Residual voltage max. I and rated U standard
		
max.
Input / Ouput isolation
TEMPERATURE
	Storage
	Operating

	
	
	
	
	
	
	

20,4 V to 26,4 V AC
8,5 mA
13 V AC
6 ms / 10 ms
1 mA

	
	
	
	
	

58 V / 30 mA
2,3 V DC
2,7 V DC

	
	
	

- 30°C to + 80°C
- 20°C to + 55°C

2,5 kV

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

40,8 V to 52,8 V AC
4,5 mA
22 V AC
6 ms / 10 ms
1 mA
58 V / 30 mA
2,3 V
2,7 V
2,5 kV
- 30°C to + 80°C
- 20°C to + 55°C

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

98 V to 126,5 V AC
8 mA
50 V AC
6 ms / 10 ms
2 mA
58 V / 30 mA
2,3 V
2,7 V
2,5 kV
- 30°C to + 80°C
- 20°C to + 55°C

	
	
	
	
	
	
	
	
	
	
	
	
	
	
	

195,5 V to 253 V AC
7 mA
95 V AC
6 ms / 10 ms
2 mA
58 V / 30 mA
2,3 V
2,7 V
2,5 kV
- 30°C to + 80°C
- 20°C to + 55°C

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/74

100 mA output optocoupler

Transistor output
optocoupler plugs

2CDC 292 013 F0013

2

3

4

1

2

3

N5V-3

4

100 mA output optocoupler

24 V DC

2

1

3

4

1

2

3

N24V-3

P5V-3
Derating curve

4

48 V DC

1

2

P24V-3

3

100

2

3

0

 (°C)

57 60

0

57 60

 (°C)

Type	P/N

Type	P/N

	BNMS N5V-3
BNMS
P5V-3
	

	
BNMS
N24V-3
	
BNMS
P24V-3

BNMS
N48V-3
	
	
BNMS
P48V-3

1SNA031809R2600

1SNA031807R1400
1SNA031810R1200

1SNA031808R2500
1SNA031811R0700

Characteristics
	
	
	
	
	
	

4,5 V to 5,5 V DC
8,5 mA
2,9 V DC
20 µs / 1,3 ms
1 mA

OUTPUT
Max. voltage / Max. current
Residual voltage max. I and rated U
		
standard U
		
max.
Frequency on inductive load
Input / Output isolation

	
	
	
	
	
	

58 V / 100 mA
1 V DC
1,3 V DC
See Note 1
2,5 kV

	
	
	
	
	
	
	

TEMPERATURE
	Storage
	Operating

	
	

- 30°C to + 80°C
- 20°C to + 60°C

	
	

	
	
	
	
	

20,4 V to 28,8 V DC
4,8 mA
16 V DC
20 µs / 1,3 ms
1 mA

	
	
	
	
	

1 V DC
1,3 V DC
See Note 1
2,5 kV

	
	
	
	
	
	
	

- 30°C to + 80°C
- 20°C to + 60°C

	
	

58 V / 100 mA

1 A output optocoupler

MOS output
optocoupler plugs

40,8 V to 57,6 V DC
3,9 mA
26 V DC
20 µs / 1,3 ms
1 mA

58 V / 100 mA
1 V DC
1,3 V DC
See Note 1
2,5 kV

- 30°C to + 80°C
- 20°C to + 60°C

1 A output optocoupler

5 V DC

24 V DC

Note 1 :
Fmax = (1-0,007 x Us) / (L x Is²)
or
Fmax = (1-0,007 x Us) / (P x L )
R

2CDC 292 013 F0013

5

INPUT
Voltage
Max. current
Typical triggering threshold at Is = 100 %
Switching time	
C/O
Leakage current

Part numbers

2

3

4

1

2

3

N5V-2

4

1

2

P5V-2

3

4

1

2

3

1

Derating curve

Type	P/N

Type	P/N

	
BNMS
N5V-2
	
BNMS
P5V-2

	
BNMS
N24V-2
	
BNMS
P24V-2

1SNA031816R0400
1SNA031818R1600

4

P24V-2

N24V-2

Derating curve

1SNA031817R0500
1SNA031819R1700

Characteristics
INPUT
Voltage
Max. current
Typical triggering threshold at Is=100%
Switching time	
C/O
Leakage current

	
	
	
	
	

4,5 V to 5,5 V DC
12,5 mA
3,5 V DC
20 µs / 250 µs
1 mA

	
	
	
	
	

20,4 V to 28,8 V DC
6,7 mA
10 V DC
50 µs / 350 µs
1 mA

OUTPUT
Max. voltage / Max. current
Residual voltage max. I and rated U
		
standard U
		
max.
Frequency on inductive load
Input / Output isolation

	
	
	
	
	
	

58 V / See graphs

	

58 V / See graphs

1 V DC
1,3 V DC
See Note 1
2,5 kV

	
	
	
	

1 V DC
1,3 V DC
See Note 1
2,5 kV

TEMPERATURE
	Storage
	Operating

	
	

- 30°C to + 80°C
- 20°C to + 60°C

	
	

- 30°C to + 80°C
- 20°C to + 60°C

5/75 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

1

100

Type	P/N
1SNA031806R1300

4

P48V-3

I (mA)

100
 (°C)

1

Derating curve

I (mA)

57 60

4

N48V-3

Derating curve

I (mA)

0

Part numbers

100 mA output optocoupler

5 V DC

Us	
Is	
L	
P	
R	

= Output voltage supply
= Output current
= Inductive load
= Load power
= Load resistance

2 A output optocoupler

2 A output optocoupler

MOS output
optocoupler plug

24 V DC

5 V DC

Note 2 :
Fmax = (1 - 0,012 x Us) / (L x Is²)
or
Fmax = (1 - 0,012 x Us) / (P x L )
R

2CDC 292 013 F0013

2

3

4

1

2

3

N5V-1

4

2

1

P5V-1

3

4

1

N24V-1

Derating curve

Part numbers

2

3

4

1

P24V-1
Derating curve

Type	P/N

Type	P/N

	
BNMS
N5V-1
	
BNMS
P5V-1

BNMS
	
N24V-1
	
BNMS
P24V-1

1SNA031812R0000
1SNA031814R0200

Us	 = Output voltage supply
Is	 = Output current
L	 = Inductive load
P	 = Load power
R	 = Load resistance

1SNA031813R0100
1SNA031815R0300

Characteristics
INPUT
Voltage
Max. current
Typical triggering threshold
Switching time	
Leakage current

C/O

	
	
	
	
	

4,5 V to 5,5 V DC
12,5 mA
3,5 V DC
20 µs / 250 µs
1 mA

	
	
	
	
	
	

20,4 V to 28,8 V DC
6,7 mA
10 V DC
50 µs / 350 µs
1 mA

OUTPUT
Max. voltage / Max. current
Residual voltage max. I and rated U
		
standard U
		
max.
Frequency on inductive load
Input / Output isolation

	
30 V DC / See graphs
		
	
1 V DC
	
1,3 V DC
	
See Note 2
	
2,5 kV

	
30 V / See graphs
		
	
1 V DC
	
1,3 V DC
	
See Note 2
	
2,5 kV

TEMPERATURE
	Storage
	Operating

	
	

	
	

- 30°C to + 80°C
- 20°C to + 60°C

5

- 30°C to + 80°C
- 20°C to + 60°C

1 A output optocoupler

Triac output
optocoupler plug
2CDC 292 013 F0013

24 V DC

2

3

4

1

Derating curve

Part numbers

Type	P/N
	BNMS A24V-4

1SNA031839R1300

Characteristics
INPUT
Voltage
Max. current
Typical triggering threshold
Switching time	
Leakage current

C/O

	
	
	
	
	

20,4 V to 28,8 V DC
3,8 mA
10 V DC
9,5 ms / 12 ms

OUTPUT
Max. voltage / Max. current
Residual voltage max. I and rated U
		
standard U
		
max.
Input / Output isolation

	 24 V to 253 V AC / See derating curve
		
	
1 V AC
	
1,3 V AC
	
2,5 kV

TEMPERATURE
	Storage
	Operating

	
	

- 30°C to + 80°C
- 20°C to + 70°C

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/76

Relay plugs

1 SPDT relay

2CDC 292 013 F0013

Derating curve
I(A)
6

2

5

4

2

1

0

1SNA031820R1400

	BNMS R24V-2

1SNA031847R1300

BNMS R24V-1	

Analogical plugs
2CDC 292 013 F0013

20

30

40 44

52 55

Θ(°C)

Limited load in CC
Voltage (Vcc)

	

	BNMS R24V-1

BNMS R24V-2

Current / Voltage Converter

2

3

4

Voltage (Vcc)

COIL
		 20,4 V to 28,8 V DC
Voltage
		
7 mA
Current max.
		
1,2 V
Trip voltage
CONTACT
		
1 SPDT
Type
	
12 V / 250 V		
5 V / 250 V
Voltage mini. / max.
	
10 mA / 6 A		
1 mA / 6 A
Switching current mini. / max.
Switching current	
AC1 mini. / max. 	 0,6 VA/1500 VA (resistance)		 0,05 VA/1500 VA (resistance)
0,6 W / 140 W		
0,05 W / 140 W
		
DC1 mini. / max. 	
Number of operations	
on load 		105 operations for AC15
Number of operations	
off load 		10x106 operations
6 ms / 8 ms
Operating speed	
C/O 		
		
1,5 ms
Bounce
4 kV
Isolation		
Coil / Contact 		
4 kV
Resistance to shock waves	 Coil / Contact 		
1 kV
Isolation		
Contact / Contact 		
TEMPERATURE
		
- 40°C to + 80°C
	Storage
		
- 20°C to + 55°C
	Operating

Part numbers

10

Type	P/N

Current (Acc)

Current (Acc)

	
24 V	
110/120 V	
220/230 V	

DC12	
6 A	
0,3 A	
0,2 A	

1

2

3

4

Type	P/N

Type	P/N

1SNA031832R0400

DC13	
1 A	
0,2 A	
0,1 A	

AC15
3A
3A
3A

1

Plug with 500 Ω accuracy resistance for
analogical signals.

BNMS
	
CA I/U-250

AC12	
6 A	
6 A	
6 A	

Current / Voltage Converter

Plug with 250 Ω accuracy resistance for
analogical signals.

BNMS
	
CA I/U-500

1SNA031833R0500

Characteristics
Resistance
Power
Accuracy
Stability

	250 Ω
	
0,35 W
	
0,1 %
	
25 ppm

Fuse and strap plugs

	500 Ω
	
0,35 W
	
0,1 %
	
25 ppm

Output fuse plug

2CDC 292 013 F0013

5

3

R24V-1

Part numbers

Characteristics

24 V DC

2

4

Input fuse plug

1

2

5

4

1

Strap plug

2

1

BNMS ST1

Part numbers

Type	P/N
		
BNMS
	
	BNMS
	
	BNMS
	
	BNMS
	
	BNMS
	
	BNMS
	
	BNMS

F125mA-1
F500mA-1
F2A-1
F5A-1
F125mA-2
F2A-2
F5A-2

125 V / 125 mA
125 V / 500 mA
125 V / 2 A
125 V / 5 A
250 V / 125 mA
250 V / 2 A
250 V / 5 A

Type	P/N

1SNA031821R0100 BNMS
F125mA-3
	 	
1SNA031838R1200 BNMS
F125mA-4
	 	
1SNA031822R0200
1SNA031823R0300
1SNA031824R0400
1SNA031825R0500
1SNA031826R0600

5/77 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

125 V / 125 mA
250 V / 125 mA

1SNA031827R0700
	
1SNA031828R1000
	

2

3

1

BNMS ST2

Type	P/N
BNMS ST1
BNMS ST2

1SNA031829R1100
1SNA031830R1600

End stops
The end stops are mounted at the extremity of the terminal board assembly, giving additional support to the terminal blocks
as markers. For various types of marking, refer to the marker section.

BADL

Description	
Type		
Order P/N				
Packaging	Weight
								kg

BAM2

BAMH
BADH

End stop DIN 3
BADL	
9 mm					
1SNA399903R0200
						
grey V0	
End stop with screws DIN 3
BAM2 V0	 10 mm					
1SNA399967R0100
						
grey V0	
BAM2	
10 mm					
1SNA206351R1600
						
grey V2	
BAM2 V0	 10 mm					
1SNA296351R0000
						
beige V0	
High end stop with screws DIN 1
					
BAMH	
9,1 mm					
1SNA114836R0000
and
DIN 3	
grey	
BAMH V0	 9,1 mm					
1SNA194836R0100
						
beige V0	
High end stop with screws DIN 3
					
BADH	
12 mm					
1SNA116900R2700
	grey	

50
50
50
50
50
50
50

Mounting rails
PR30

PR3.Z2

PR3.G2

PR5

PR4

Symmetrical zinc bichromate plated
steel
prepunched rail
					
PR30	
2 m					
1SNA173220R0500
Symmetrical zinc bichromate plated
steel
rail
					
PR3.Z2	 2 m					
1SNA174300R1700
White, symmetrical passivated
galvanized
steel
rail
					
PR3.G2	 2 m					
1SNA164800R0300
Symmetrical zinc bichromate plated
steel
rail
					
PR5	
2 m					
1SNA168700R2200
Symmetrical zinc bichromate plated
steel
rail
					
PR4	
2 m					
1SNA168500R1200

1
1

5

1
1
1

Test devices
FC2

Test
plug DIA. 2 mm
					
FC2							
1SNA007865R2600

10

Assembled jumper bar

BJ612-...

This accessory permits electrical connection between 2 to 70 blocks with 6 mm spacing placed side by side.
It can be used with screw clamp or spring clamp blocks with 6 mm or 12 mm spacing.
Interconnection of blocks not placed side by side is possible if teeth of the jumper bar have been cut in front
of the blocks not to be connected. These teeth can be removed using pliers.
Use of separator end sections before and after the jumper bar is required to preserve IP20 protection of the
assembly.
Assembled
jumper bar 10 poles - 24 A
	 				
BJ612-10							
1SNA290488R0100
Assembled
jumper bar 20 poles - 24 A
	 				
BJ612-20							
1SNA206754R0000

10
10

Separator end section
Directly mounted on the rail beside the block, it permits to identify and make electrical insulation of product
groups using jumper bars. Dimensions are the same as screw clamp blocks : width 70 mm and height on rail
67,5 mm with 2 mm spacing.
SC612

Separator
end section
	
SC612							
				
1SNA290474R0200

Distribution module

This terminal block with BJ612-... jumper bars permits
2 polarities distribution (PCL side and process side) thanks to
two separate circuits, each of them including :
	
- one 4 mm² input,
	
- two 2,5 mm² outputs
	
- one double output for jumper bar BJ612-...

2,5 mm²

..

2-.

61

BJ

10

2,5 mm²

4 mm²

..

2-.

61

BJ

It permits also the connection of ground to the rail though a 4
mm² input.

4 mm²
4 mm²

D4/12-3...

Rated voltage :	
250 VAC-DC
Rated current :	
32 A (4 mm²) - 16 A (2,5 mm²)
Recommended torque :	 0,4 - 0,6 Nm

Screw
clamp distribution block sp. 12 mm
	
D4/12-3-3							
				
1SNA645031R2000	
Spring
clamp distribution block sp. 12 mm
	
D4/12-3R-3R						
				
1SNA645531R2200

5
5

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/78

Accessories
PCMS

PEF

Comb-type jumper

Identification label holders

This accessory permits the electrical connection of
2 to 22 blocks.

Designed to hold RPEV label (see opposite).

	No.	
Grey	
Red	
Blue	
Green/Yellow
	
of	UL94V0	UL94V0	UL94V0	UL94V0
	
poles

5

	2
		
1SNA205491R2300	
	3
		
1SNA205495R2700	
	4
		
1SNA205499R0300	
	5
		
1SNA205503R0700	
	6
		
1SNA205507R0300	
	7
		
1SNA205511R2600	
	8
		
1SNA205515R2200	
	9
		
1SNA205519R0600	
	10 1SNA205523R2200	
		
	11 1SNA205527R2600	
		
	12 1SNA205531R2200	
		
	13 1SNA205535R2600	
		
	14 1SNA205539R0200	
		
	15 1SNA205543R0600	
		
	16 1SNA205547R0200	
		
	17 1SNA205551R0600	
		
	18 1SNA205555R0200	
		
	19 1SNA205559R1600	
		
	20 1SNA205563R0200	
		
	21 1SNA205567R0600	
		
	22 1SNA205571R0200	
		

1SNA205492R2400	
1SNA205496R2000	
1SNA205500R1000	
1SNA205504R0000	
1SNA205508R1400	
1SNA205512R2700	
1SNA205516R2300	
1SNA205520R0300	
1SNA205524R2300	
1SNA205528R0700	
1SNA205532R2300	
1SNA205536R2700	
1SNA205540R1700	
1SNA205544R0700	
1SNA205548R1300	
1SNA205552R0700	
1SNA205556R0300	
1SNA205560R1300	
1SNA205564R0300	
1SNA205568R1700	
1SNA205572R0300	

1SNA205493R2500	
1SNA205497R2100	
1SNA205501R0500	
1SNA205505R0100	
1SNA205509R1500	
1SNA205513R2000	
1SNA205517R2400	
1SNA205521R2000	
1SNA205525R2400	
1SNA205529R0000	
1SNA205533R2400	
1SNA205537R2000	
1SNA205541R0400	
1SNA205545R0000	
1SNA205549R1400	
1SNA205553R0000	
1SNA205557R0400	
1SNA205561R0000	
1SNA205565R0400	
1SNA205569R1000	
1SNA205573R0400	

1SNA205494R2600
1SNA205498R0200
1SNA205502R0600
1SNA205506R0200
1SNA205510R0100
1SNA205514R2100
1SNA205518R0500
1SNA205522R2100
1SNA205526R2500
1SNA205530R0500
1SNA205534R2500
1SNA205538R0100
1SNA205542R0500
1SNA205546R0100
1SNA205550R1100
1SNA205554R0100
1SNA205558R1500
1SNA205562R0100
1SNA205566R0500
1SNA205570R1500
1SNA205574R0500

	
PEF 	*
* Delivered with labels.

	

1SNA020568R0400

The label holders are removable and the labels can be changed easily.
	 For mounting on PCB in a 3,7 mm 	
	 diameter hole.

RPEV

Label for PEF 29 x 6 mm
Sheets of 99 pre-cut labels

		
RPEV

✓ Blank

1SNA173178R0700

DC	

PC

Test device on screw head

Comb-type jumper bar

This patented device is mounted on the round
screwdriver opening. It is used for trouble shooting,
measuring and control for monitoring and repairing
an installation, on blocks without a test socket. For
this, the device receives an FC2 test plug.

	 For mounting on a PCB block in a 2 mm 	
	 diameter hole (no support leg).

PC	EIP

blue for MA 2,5/5 blocks

This accessory can be used only on the terminal blocks with at least
one compression clamp connection. It permits the electrical connection of 2 to 10 blocks.
Interconnection of non-consecutive blocks is possible by removing
the teeth opposite the blocks which must not be connected. The
comb-type jumper bars can be cut using pliers (or a saw) : in this case,
the use of an insulating tip EIP is recommended. The comb is placed
in the compression clamp before tightening the screws, above the
eventual conductor.

					
	DCB	
		 1SNA105028R2100	

To be mounted on blocks series R900 and R910 :

The DC's are differentiated by their colour :

BJ	
		
BJS

Jumper bar not assembled

To be mounted on blocks series R910 :
Screw + washer + post

EV6D	
	
			
1SNA168400R1600	

Perforated jumper bar	

8 poles
BJS9
32 A
			
1SNA177583R1200	

	

16 poles 1SNA177584R1300	
BJS9
32 A	
			
	

	 RLV
	

EIP

Comb-type jumper bar

PC9	

Jumper bar

Subassembly
To connect terminal blocks, place the metal tube into
screw + washer + post
the top center hole on each terminal block to be
connected.
The metal tube contacts the terminal block's internal
Perforated jumper bar
connector bar.
to be cut to length
The perforated bar is cut to length and placed flat
along the center opening of the series of terminal blocks.
The screw is inserted into the perforated bar's hole which is located directly
above the blocks being connected. The screw goes through the threaded
metal tube and is screwed into the terminal block's internal connector bar.
This completes the electrical connection to the perforated bar and connects
the block.

	RL	

Insulating tip for comb

Lengthwise marker
Lengthwise marker
Width 9 mm .354"

Large area for writing.
To be snapped onto the top of blocks.
Blank marker for writing :

	
RLV

1SNA103849R0300

1SNA113550R2000
15 A

10 poles

1SNA210160R1200

IDC jumper

(insulation displacement jumper)
Characteristics
Wire size
mm² / AWG

	IEC	
	NFC

Rigid

Flexible
Voltage			 V 	
Current			A
Rated wire size			 mm² / AWG
Working temperature			 °C
Protection			

VDE	

	 2,5 mm²	
		
	 2,5 mm²	

CSA
14 AWG

	600	
600
	26	
15
2
	 2,5 mm 	 14 AWG
-55°C -> +110°C
	
IP20 / NEMA1

Quick-jump lets you interconnect screw clamp terminals of different sizes, levels and all manufacturers
quickly and safely. Its insulation displacement technology makes it easy to use, fast, economical and does
not require a special tool. Use as a jumper between relays, switches and other electronic components.
ABB Quick-jump will fit any screw clamp type terminal block, from 6 mm .238" spacing and larger.
How to use : connecting Quick-jump to your terminal

3
4

1 - Insert ABB Quick-jump into your terminal screw clamp.
2 - Tighten the terminal screw.
3 - Guide jumper wire through the V-shaped opening in the Quick-jump.
4 - Secure the wire by closing the Quick-jump lever with any flat nose pliers.

2

1

Adding a shunt in an installation :
1 - Insert ABB Quick-jump into your terminal screw clamp.
2 - Guide the terminal screw clamp into contact with the wire.
3 - Secure the wire by closing the Quick-jump lever with any flat nose
pliers.
4 - Tighten the terminal screw.
jumper
	Insulation displacement
	

5/79 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

AD 2,5

4

3

1SNA114205R2000

1
2

Marking for Interface Modules
Selection table

	Markers for
modules :	 RC610	RC55	 RC65	
	R500	

1

Remove one of the side bands of the card.

2

Separate the chosen strip from the rest
of the card.

3

Press the first marker in place, hold it and slide
your thomb on the rest of the strip.

Horizontal marking

Vertical marking

	

	R600	

	

	R900	

	

	R910	

	

	R1800	

	

	

	 Possible mounting : POSSIBLE

POSSIBLE 	

	

	 Recommended mounting :

POSSIBLE 	

	 Impossible mounting :

	

Marking for terminal blocks
5

Standard RC marker cards
		
		

(x) = Nb of cards	
in 5 mm spacing kit	

(x) = Nb of cards		(x) = Nb of cards
in 6 mm spacing kit		in 6 mm spacing kit

	 Marker sizes	

RC55	

RC65	

RC610

	 Blank cards
		

1SNA230000R1200	

1SNA232000R0000	

1SNA233000R0100

	 Horizontal marking
	
	 10 strips from 1 to 10
		
		
	 10 strips from 11 to 20
		
	 10 strips from 21 to 30
		
	 10 strips from 31 to 40
		
	 10 strips from 41 to 50
		
	 10 strips from 51 to 60
		
	 10 strips from 61 to 70

1SNA230002R0000 (5)	
1SNA230003R0100 (2)	
1SNA230004R0200	
1SNA230005R0300	
1SNA230006R0400	
1SNA230007R0500	
1SNA230008R1600	

1SNA232002R2600 (5)	
1SNA232003R2700 (2)	
1SNA232004R2000	
1SNA232005R2100	
1SNA232006R2200	
1SNA232007R2300	
1SNA232008R0400	

1SNA233002R2700 (25)
1SNA233003R2000 (10)
1SNA233004R2100 (6)
1SNA233005R2200 (4)
1SNA233006R2300 (3)
1SNA233007R2400 (2)
1SNA233008R0500 (2)

	 From 1 to 100
		
		
	 From 101 to 200

1SNA230030R0700 (2)	
1SNA230031R2400	

1SNA232030R2500 (2)	
1SNA232031R1200	

1SNA233030R2600 (15)
1SNA233031R1300 (2)

		
	 20 times L1-L2-L3-N-PE

1SNA230131R2500	

1SNA232131R1300	

1SNA233131R1400 (2)	

	 Vertical marking
	
		
	 10 strips from 1 to 10
		
	 10 strips from 11 to 20
		
	 10 strips from 21 to 30
		
	 10 strips from 31 to 40

1SNA230041R0600	
1SNA230042R0700	
1SNA230043R0000	
1SNA230044R0100	

1SNA232041R2400	
1SNA232042R2500	
1SNA232043R2600	
1SNA232044R2700	

1SNA233041R2500 (5)
1SNA233042R2600 (3)
1SNA233043R2700 (2)
1SNA233044R2000 (2)

		
	 From 1 to 100

1SNA230060R1500	

1SNA232060R0300	

1SNA233060R0400 (8)

Marking kit RC 5 mm spacing or 6 mm spacing
Box with 100 cards with 18 various part numbers (see table next page)
Description	
Type		
Order P/N				
Packaging	Weight
								kg

Refilable box of 100 cards of
18 RC markers

								
Box
with 100 cards RC 5 mm spacing
				
1SNA400085R2700
								
Refill
for box RC 5 mm
				
1SNA400145R0700

1
1

								
Box
with 100 cards RC 6 mm spacing
				
1SNA400084R2600
								
Refill
for box RC 6 mm
				
1SNA400144R0600

1
1

2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

5/80



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2013:11:28 11:11:34+01:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2014:01:27 11:53:06+05:30
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Instance ID                     : uuid:3da28e89-4f94-4306-a650-e1f9cc482686
Original Document ID            : adobe:docid:indd:df79d2d0-e133-11e0-b6ce-b704341a6fd2
Document ID                     : xmp.id:8D46FAE31258E311B1F591687500FAA0
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:68CBE41A0746E3119A5BE3FDA3557FBC
Derived From Document ID        : xmp.did:1172188A6645E3119A3D8075F48CC363
Derived From Original Document ID: adobe:docid:indd:df79d2d0-e133-11e0-b6ce-b704341a6fd2
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:11:28 11:11:51+01:00
Metadata Date                   : 2014:01:27 11:53:06+05:30
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Layout                     : TwoPageLeft
Page Mode                       : UseOutlines
Page Count                      : 80
EXIF Metadata provided by EXIF.tools

Navigation menu