94262 Catalog
2014-09-04
: Pdf 94262-Catalog 94262-Catalog 662019 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 80
Download | |
Open PDF In Browser | View PDF |
Interface relays and optocouplers Product group picture 5 5/1 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays and optocouplers Table of contents Interface Relays and Optocouplers Pluggable interface relays 5/3 Table of contents 5/4 Benefits and advantages 5/5 Approvals and marks 5/6 Ordering details 5/7 Technical data 5/14 Technical data, Load limit curves 5/16 Load limit curves 5/17 Connection diagrams 5/18 Interface relays and optocouplers R500 / R600 range 5/21 Table of contents 5/22 Benefits and advantages 5/23 Type designators 5/24 Interface relays and optocouplers R500 range 5/25 Table of contents 5/26 Interface relays R500 range 5/27 Table of contents 5/28 Selection 5/29 Ordering details 5/30 Technical information 5/31 Optocouplers R500 range 5/33 Table of contents 5/34 Selection 5/35 Ordering details 5/36 Connection diagrams 5/37 Technical data 5/38 Interface relays and optocouplers R600 range 5/45 Table of contents 5/46 Interface relays R600 range 5/47 Table of contents 5/48 Benefits and advantages 5/49 Selection 5/51 Ordering details 5/53 Connection diagrams 5/55 Technical data 5/56 General technical data 5/61 Dimensional drawings, Load limit curves 5/62 Optocouplers R600 range 5/63 Table of contents 5/64 Selection 5/65 Ordering details 5/67 Connection diagrams 5/68 Technical data 5/69 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/2 5 Pluggable interface relays Product group picture 5 5/3 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Pluggable interface relays Table of contents Pluggable interface relays Product group picture 5/3 Table of contents 5/4 Benefits and advantages 5/5 Approvals and marks 5/6 Ordering details 5/7 Technical data 5/14 Technical data, Load limit curves 5/16 Load limit curves 5/17 Connection diagrams 5/18 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/4 Pluggable interface relays Benefits and advantages Pluggable pcb relays CR-P Pluggable miniature relays CR-M Pluggable universal relays CR-U 9 different coil voltages DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V 12 different coil voltages DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V 12 different coil voltages DC versions: 12 V, 24 V, 48 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V, 60 V, 110 V, 120 V, 230 V Output contacts: 1 c/o contact (16 A) or 2 c/o contacts (8 A) optionally equipped with gold contacts Output contacts 2 c/o contacts (12 A) or 3 c/o contacts (10 A) or 4 c/o contacts (6 A) optionally equipped with gold contacts, LED and free wheeling diode Logical or standard sockets Cadmium-free contact material Width of socket: 15,5 mm 5 Integrated test button for manual actuation and locking of the output contacts (blue = DC, orange = AC) that can be removed if necessary Integrated test button for manual actuation and locking of the output contacts (blue = DC, orange = AC) that can be removed if necessary Pluggable function modules Reverse polarity protection/ Free wheeling diode LED indication RC elements Overvoltage protection Output contacts 2 c/o contacts (10 A) or 3 c/o contacts (10 A) With or without integrated LED Logical or standard sockets Cadmium-free contact material Width on socket: 27 mm Pluggable function modules Reverse polarity protection/ Free wheeling diode LED indication RC elements Overvoltage protection With or without integrated LED Cadmium-free contact material Width on socket: 38 mm Pluggable function modules Reverse polarity protection/ Free wheeling diode LED indication RC elements Overvoltage protection Multifunction time module 1 1 1 2 2 2 3 3 3 4 4 4 4 1 Socket 1 Socket 1 Socket 2 Pluggable function module 2 Pluggable function module 2 Pluggable function module 3 Interface relay 3 Interface relay 3 Interface relay 4 Holder 4 Holder 4 Holder 4 Marker label 5/5 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Pluggable interface relays Approvals and marks Kinds of sockets Kind of connecting terminals Standard sockets - Position of connecting terminals: Coil connection (A1-A2) on lower socket side, contact connections (n/o and n/c contacts) on the lower and upper socket side. Logical sockets - Position of connecting terminals: Coil connection (A1-A2) on lower socket side, all contact connections (common contacts, n/o and n/c contacts) on upper socket side. Screw type Spring type Fork type Details see connection diagrams 5 Approvals and marks J existing j pending CR-M..L.. CR-M..SS CR-M..SF CR-U..S CR-U..E CR-U..SM CR-P/M CR-U J J J J 6) J 7) J J J J J J J J J 8) J J J J J J J J J J J J J J J CR-U J CR-M J CR-P J UL 508 J J 1) J cG CAN/CSA C22.2 No.14 J J 2) J 3) J Approvals G F CAN/CSA C22.2 No.14 J J J VDE J J 4) J J D GOST P Lloyds Register E CCC J L RMRS J CE J J J J 5) J J J J 8) Modules CR-PLC Sockets CR-PLS CR-PSS Relays Marks a 1) 2) 3) 4) 5) 6) 7) 8) J except 60 V DC and 125 V DC devices with gold contacts except devices with gold contacts except 60 V DC and 125 V DC devices except 125 V DC devices only devices with 4 c/o contacts except CR-P/M 42B, CR-P/M 42BV, CR-P/M 42C, CR-P/M 42CV, CR-P/M 52D, CR-P/M 62E, CR-P/M 62EV, CR-P/M 62D, CR-P/M 62DV except CR-U 41B, CR-U 41BV, CR-U 41C, CR-U 41CV, CR-U 51D, CR-U 61CV, CR-U 61E, CR-U 61EV, CR-U 61D, CR-U 61DV, CR-U 91C, CR-U T except 60 V and 125 V devices 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/6 2CDC 291 045 F0004 Pluggable interface relays Ordering details CR-P Description Interface relays are widely used in various industrial applications: As an interface they link the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems, to the sensor / actuator level. Here, they take on various functions: Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal protective circuits and thus are overload-proof against short-time variations like current or voltage peaks. Ordering details - CR-P range Rated control supply voltage 5 Outputs Contact ratings Type Order code Price Pkg Weight (1 pce) qty kg (lb) 12 V DC 24 V DC CR-P012DC1 CR-P024DC1 1SVR405600R4000 1SVR405600R1000 48 V DC CR-P048DC1 1SVR405600R6000 110 V DC CR-P110DC1 1SVR405600R8000 24 V AC 48 V AC CR-P024AC1 1SVR405600R0000 CR-P048AC1 1SVR405600R5000 CR-P110AC1 CR-P120AC1 CR-P230AC1 1SVR405600R7000 1SVR405600R2000 1SVR405600R3000 12 V DC 24 V DC CR-P012DC2 1SVR405601R4000 CR-P024DC2 1SVR405601R1000 48 V DC CR-P048DC2 1SVR405601R6000 110 V DC CR-P110DC2 1SVR405601R8000 CR-P024AC2 CR-P048AC2 CR-P110AC2 1SVR405601R0000 1SVR405601R5000 1SVR405601R7000 120 V AC CR-P120AC2 1SVR405601R2000 230 V AC CR-P230AC2 1SVR405601R3000 24 V DC CR-P024DC2 1SVR405606R1000 CR-P024AC2G 1SVR405606R0000 CR-P110AC2G 1SVR405606R7000 CR-P230AC2G 1SVR405606R3000 1 c/o (SPDT) 250 V, 16 A 110 V AC 120 V AC 230 V AC 24 V AC 48 V AC 110 V AC 24 V AC 110 V AC 2 c/o (SPDT) 2 c/o (SPDT) gold contact 250 V, 8 A 250 V, 8 A CR-PLS 2CDC 291 006 F0011 230 V AC Version 10 0.014 (0.031) 10 0.014 (0.031) Connection Type terminal Order code Price Pkg Weight (1 pce) qty kg (lb) Logical socket with protective separation 2CDC 291 004 F0007 0.014 (0.031) Ordering details - Accessories screw CR-PLS 1SVR405650R0000 screw CR-PLSx 1SVR405650R0100 Logical socket CR-PJ 10 Standard socket 0.045 (0.099) 10 0.043 (0.095) spring CR-PLC 1SVR405650R0200 0.042 (0.093) screw CR-PSS 1SVR405650R1000 0.038 (0.084) CR-PH 1SVR405659R0000 Plastic holder for socket 10 Jumper bar for sockets with screw connection CR-PJ 1SVR405658R5000 Marker CR-PM 1SVR405658R0000 Bold printed products = stocked products 5/7 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 10 0.002 (0.004) 0.018 (0.040) 0.0002 (0.0004) 2CDC 291 046 F0004 Pluggable interface relays Ordering details CR-M Description Interface relays are widely used in various industrial applications: As an interface they link the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems, to the sensor / actuator level. Here, they take on various functions: Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal protective circuits and thus are overload-proof against short-time variations like current or voltage peaks. Ordering details - CR-M range without LED Rated control supply voltage Outputs Contact ratings Type Order code Price Pkg Weight (1 pce) qty kg (lb) 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 2 c/o (SPDT) CR-M012DC2 CR-M024DC2 CR-M048DC2 CR-M060DC2 CR-M110DC2 CR-M125DC2 250 V, 12 A CR-M220DC2 1SVR405611R4000 1SVR405611R1000 1SVR405611R6000 1SVR405611R4200 1SVR405611R8000 1SVR405611R8200 1SVR405611R9000 CR-M024AC2 CR-M048AC2 CR-M110AC2 CR-M120AC2 CR-M230AC2 1SVR405611R0000 1SVR405611R5000 1SVR405611R7000 1SVR405611R2000 1SVR405611R3000 CR-M012DC3 CR-M024DC3 CR-M048DC3 CR-M060DC3 CR-M110DC3 CR-M125DC3 250 V, 10 A CR-M220DC3 1SVR405612R4000 1SVR405612R1000 1SVR405612R6000 1SVR405612R4200 1SVR405612R8000 1SVR405612R8200 1SVR405612R9000 CR-M024AC3 CR-M048AC3 CR-M060AC3 CR-M110AC3 CR-M120AC3 CR-M230AC3 1SVR405612R0000 1SVR405612R5000 1SVR405612R5200 1SVR405612R7000 1SVR405612R2000 1SVR405612R3000 CR-M012DC4 CR-M024DC4 CR-M048DC4 CR-M060DC4 CR-M110DC4 CR-M125DC4 CR-M220DC4 1SVR405613R4000 1SVR405613R1000 1SVR405613R6000 1SVR405613R4200 1SVR405613R8000 1SVR405613R8200 1SVR405613R9000 CR-M024AC4 CR-M048AC4 CR-M110AC4 CR-M120AC4 CR-M230AC4 1SVR405613R0000 1SVR405613R5000 1SVR405613R7000 1SVR405613R2000 1SVR405613R3000 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 3 c/o (SPDT) 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 4 c/o (SPDT) 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 250 V, 6 A 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) Bold printed products = stocked products 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/8 5 Pluggable interface relays Ordering details Ordering details - CR-M range 2CDC 291 046 F0004 Rated control supply voltage CR-M Outputs Contact ratings Order code Price Pkg Weight (1 pce) qty kg (lb) CR-M012DC2L CR-M024DC2L CR-M048DC2L CR-M060DC2L CR-M110DC2L CR-M125DC2L CR-M220DC2L 1SVR405611R4100 1SVR405611R1100 1SVR405611R6100 1SVR405611R4300 1SVR405611R8100 1SVR405611R8300 1SVR405611R9100 CR-M024AC2L CR-M048AC2L CR-M110AC2L CR-M120AC2L CR-M230AC2L 1SVR405611R0100 1SVR405611R5100 1SVR405611R7100 1SVR405611R2100 1SVR405611R3100 CR-M012DC3L CR-M024DC3L CR-M048DC3L CR-M060DC3L CR-M110DC3L CR-M125DC3L CR-M220DC3L 1SVR405612R4100 1SVR405612R1100 1SVR405612R6100 1SVR405612R4300 1SVR405612R8100 1SVR405612R8300 1SVR405612R9100 CR-M024AC3L CR-M048AC3L CR-M110AC3L CR-M120AC3L CR-M230AC3L 1SVR405612R0100 1SVR405612R5100 1SVR405612R7100 1SVR405612R2100 1SVR405612R3100 CR-M012DC4L CR-M024DC4L CR-M048DC4L CR-M060DC4L CR-M110DC4L CR-M125DC4L 250 V, 6 A CR-M220DC4L 1SVR405613R4100 1SVR405613R1100 1SVR405613R6100 1SVR405613R4300 1SVR405613R8100 1SVR405613R8300 1SVR405613R9100 CR-M024AC4L CR-M048AC4L CR-M110AC4L CR-M120AC4L CR-M230AC4L 1SVR405613R0100 1SVR405613R5100 1SVR405613R7100 1SVR405613R2100 1SVR405613R3100 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 2 c/o (SPDT) with LED 250 V, 12 A 24 V AC 48 V AC 5 Type 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 3 c/o (SPDT) with LED 250 V, 10 A 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC 220 V DC 4 c/o (SPDT) with LED 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC2 24 V DC 4 c/o (SPDT), LED and free-wheeling diode 250 V, 6 A CR-M024DC4LD 1SVR405614R1100 24 V DC CR-M024DC4G 1SVR405618R1000 24 V AC CR-M024AC4G 250 V, 6 A CR-M110AC4G CR-M230AC4G 1SVR405618R0000 1SVR405618R7000 1SVR405618R3000 110 V AC 4 c/o (SPDT), gold contacts 230 V AC Bold printed products = stocked products 5/9 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) 10 0.033 (0.073) Pluggable interface relays Ordering details Rated control supply voltage Outputs Contact ratings Type Order code Price Pkg Weight (1 pce) qty kg (lb) 2CDC 291 046 F0004 12 V DC 24 V DC 48 V DC 60 V DC 110 V DC 125 V DC CR-M 220 V DC 24 V AC 4 c/o (SPDT) with gold contacts and LED 250 V / 6A 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 4 c/o (SPDT) with gold contacts, LED and free-wheeling diode CR-M012DC4LG CR-M024DC4LG CR-M048DC4LG CR-M060DC4LG CR-M110DC4LG CR-M125DC4LG CR-M220DC4LG 1SVR405618R4100 1SVR405618R1100 1SVR405618R6100 1SVR405618R4300 1SVR405618R8100 1SVR405618R8300 1SVR405618R9100 10 0.033 (0.073) CR-M024AC4LG CR-M048AC4LG CR-M110AC4LG CR-M120AC4LG CR-M230AC4LG 1SVR405618R0100 1SVR405618R5100 1SVR405618R7100 1SVR405618R2100 1SVR405618R3100 10 0.033 (0.073) CR-M012DC4LDG 1SVR405618R4400 10 CR-M024DC4LDG 1SVR405618R1400 0.033 (0.073) Ordering details - Accessories 2CDC 291 009 F0011 Version CR-M4SS Connection Type terminal Price Pkg Weight (1 pce) qty kg (lb) Logical socket for 2 c/o 0.055 (0.121) CR-M2LS 1SVR405651R1100 CR-M3LS 1SVR405651R2100 Logical socket for 2/4 c/o CR-M4LS 1SVR405651R3100 0.066 (0.146) Logical socket for 2 c/o CR-M2LC 1SVR405651R1200 0.065 (0.143) CR-M4LC 1SVR405651R3200 0.066 (0.146) CR-M2SS 1SVR405651R1000 0.066 (0.146) CR-M3SS 1SVR405651R2000 Standard socket for 2/4 c/o CR-M4SS 1SVR405651R3000 0.070 (0.154) Standard socket for 2 c/o CR-M2SF 1SVR405651R1300 0.040 (0.088) CR-M4SF 1SVR405651R3300 Plastic holder CR-MH 1SVR405659R1000 10 0.003 (0.007) Metal holder CR-MH1 1SVR405659R1100 10 0.0005 (0.001) Jumper bar for sockets with screw connection CR-MJ 1SVR405658R6000 10 0.029 (0.064) Marker CR-MM 1SVR405658R1000 10 0.0005 (0.001) Logical socket for 3 c/o screw spring Logical socket for 2/4 c/o Standard socket for 2 c/o Standard socket for 3 c/o CR-MJ Order code screw fork type Standard socket for 2/4 c/o 10 10 10 10 0.062 (0.137) 0.068 (0.150) 0.048 (0.106) Bold printed products = stocked products 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/10 5 Pluggable interface relays Ordering details Ordering details - CR-P/M range (all products stocked) Rated control supply voltage Description Version Type Order code Price Pkg Weight (1 pce) 2CDC 291 005 S0011 qty kg (lb) CR-P/M ... 6-220 V DC 6-24 V DC 24-60 V DC 110 V DC 6-24 V AC 24-60 V AC 110-230 V AC/DC Diode and LED - Reverse polarity protection/ free wheeling diode Spark quenching 6-24 V AC/DC 24-60 V AC/DC Diode, LED and reverse polarity protection 110 V DC 110-230 V AC 6-24 V AC/DC 24-60 V AC/DC Varistor and LED Overvoltage protection 110 V DC 110-230 V AC 24 V AC 115 V AC 230 V AC A1+, A2- CR-P/M 22 1SVR405651R0000 10 0.003 (0.007) 10 0.003 (0.007) 10 0.003 (0.007) 10 0.003 (0.007) 10 0.003 (0.007) 10 0.002 (0.004) CR-P/M 42 red, A1+, A2green, A1+, A2- CR-P/M 42V 1SVR405652R0000 1SVR405652R1000 CR-P/M 42B red, A1+, A21SVR405652R4000 green, A1+, A2- CR-P/M 42BV 1SVR405652R4100 CR-P/M 42C red, A1+, A21SVR405652R9000 green, A1+, A2- CR-P/M 42CV 1SVR405652R9100 CR-P/M 52B 1SVR405653R0000 CR-P/M 52D 1SVR405653R4000 red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2- Overvoltage protection CR-P/M 52C 1SVR405653R1000 CR-P/M 62 1SVR405654R0000 CR-P/M 62V 1SVR405654R1000 CR-P/M 62E 1SVR405654R4000 CR-P/M 62EV 1SVR405654R4100 CR-P/M 92 1SVR405654R0100 CR-P/M 92V 1SVR405654R1100 CR-P/M 62C 1SVR405655R0000 CR-P/M 62CV 1SVR405655R1000 CR-P/M 62D 1SVR405655R4000 CR-P/M 62DV 1SVR405655R4100 CR-P/M 92C 1SVR405655R0100 CR-P/M 92CV 1SVR405655R1100 CR-P/M 72 CR-P/M 72A CR-P/M 82 1SVR405656R0000 1SVR405656R1000 1SVR405656R2000 2CDC 292 014 F0005 CR-P/M 42, CR-P/M 42C, CR-P/M 42BV, CR-P/M 42B, CR-P/M 42V, CR-P/M 42CV CR-P/M 62E, CR-P/M 62V, CR-P/M 92V CR-P/M 62C, CR-P/M 92C, CR-P/M 62DV CR-P/M 62D, CR-P/M 62CV, CR-P/M 92CV CR-P/M 52B, CR-P/M 52D, CR-P/M 52C CR-P/M 72, CR-P/M 72A, CR-P/M 82 2CDC 292 017 F0005 2CDC 292 018 F0005 2CDC 292 013 F0005 CR-P/M 22 CR-P/M 62, CR-P/M 92, CR-P/M 62EV, 2CDC 292 015 F0005 Connection diagrams 2CDC 292 016 F0005 5 Diode Reverse polarity protection/ free wheeling diode 5/11 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Pluggable interface relays Ordering details 2CDC 291 047 F0004 Description Interface relays are widely used in various industrial applications: As an interface they link the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems, to the sensor / actuator level. Here, they take on various functions: Switching of AC or DC loads with different resistive, inductive and capacitive parts, switching voltages from a few mV up to 250 V, switching currents from a few mA up to 16 A, amplification of weak control signals, electrical isolation of control and load circuits, and signal multiplying. In contrast to electronic switching devices, interface relays don’t use additional internal protective circuits and thus are overload-proof against short-time variations like current or voltage peaks. CR-U Ordering details - CR-U range 2CDC 291 007 S0011 Rated control supply voltage 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 12 V DC 24 V DC 48 V DC 110 V DC 220 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Outputs Contact ratings 2 c/o without LED 250 V, 10 A 3 c/o without LED 250 V, 10 A 2 c/o with LED 250 V, 10 A 3 c/o with LED 250 V, 10 A Type Order code CR-U012DC2 CR-U024DC2 CR-U048DC2 CR-U110DC2 CR-U220DC2 CR-U024AC2 CR-U048AC2 CR-U110AC2 CR-U120AC2 CR-U230AC2 CR-U012DC3 CR-U024DC3 CR-U048DC3 CR-U110DC3 CR-U125DC3 CR-U220DC3 CR-U024AC3 CR-U048AC3 CR-U060AC3 CR-U110AC3 CR-U120AC3 CR-U230AC3 CR-U012DC2L CR-U024DC2L CR-U048DC2L CR-U110DC2L CR-U220DC2L CR-U024AC2L CR-U048AC2L CR-U110AC2L CR-U120AC2L CR-U230AC2L CR-U012DC3L CR-U024DC3L CR-U048DC3L CR-U110DC3L CR-U220DC3L CR-U024AC3L CR-U048AC3L CR-U110AC3L CR-U120AC3L CR-U230AC3L 1SVR405621R4000 1SVR405621R1000 1SVR405621R6000 1SVR405621R8000 1SVR405621R9000 1SVR405621R0000 1SVR405621R5000 1SVR405621R7000 1SVR405621R2000 1SVR405621R3000 1SVR405622R4000 1SVR405622R1000 1SVR405622R6000 1SVR405622R8000 1SVR405622R8200 1SVR405622R9000 1SVR405622R0000 1SVR405622R5000 1SVR405622R5200 1SVR405622R7000 1SVR405622R2000 1SVR405622R3000 1SVR405621R4100 1SVR405621R1100 1SVR405621R6100 1SVR405621R8100 1SVR405621R9100 1SVR405621R0100 1SVR405621R5100 1SVR405621R7100 1SVR405621R2100 1SVR405621R3100 1SVR405622R4100 1SVR405622R1100 1SVR405622R6100 1SVR405622R8100 1SVR405622R9100 1SVR405622R0100 1SVR405622R5100 1SVR405622R7100 1SVR405622R2100 1SVR405622R3100 Type Order code Price Pkg Weight (1 pce) qty kg (lb) 10 0.083 (0.183) 10 0.083 (0.183) 10 0.083 (0.183) 10 0.083 (0.183) Ordering details - Accessories Version CR-U2S Socket for 2 c/o and module Socket for 3 c/o and module Socket for 3 c/o Socket small for 2 c/o Socket small for 3 c/o Holder for CR-U socket CR-U2S CR-U3S CR-U3E CR-U2SM CR-U3SM CR-UH 1SVR405670R0000 1SVR405660R0000 1SVR405660R0100 1SVR405670R1100 1SVR405660R1100 1SVR405669R0000 Price Pkg Weight (1 pce) qty kg (lb) 10 Bold printed products = stocked products 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/12 5 Pluggable interface relays Ordering details Ordering details - CR-U range (all products stocked) Rated control supply voltage Description Version Type Order code Price Pkg Weight (1 pce) 6-24 V DC CR-U... 24-60 V DC 110 V DC 5 6-24 V AC/DC 24-60 V AC/DC 110-230 V AC/DC Diode and LED - Reverse polarity protection/ free wheeling diode Diode and LED 6-24 V AC/DC Varistor and LED Overvoltage protection 2CDC 291 032 F0005 110 V DC 110-230 V AC CR-U T 24 V AC 115 V AC 230 V AC 24-240 V AC/DC 1SVR405661R0000 CR-U 41 red, A1+, A2green, A1+, A2- CR-U 41V red, A1+, A2red, A1+, A2- red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2red, for DC A1+, A2green, for DC A1+, A2- Overvoltage protection, varistor Multifunction time module pluggable onto CR-U2S and CR-U3S 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) 10 0.007 (0.015) CR-U 51B CR-U 51D 1SVR405662R0000 1SVR405662R1000 1SVR405662R4000 1SVR405662R4100 1SVR405662R9000 1SVR405662R9100 1SVR405663R0000 1SVR405663R4000 CR-U 51C 1SVR405663R1000 CR-U 61 1SVR405664R0000 CR-U 61V 1SVR405664R1000 CR-U 61E 1SVR405664R4000 CR-U 61EV 1SVR405664R4100 CR-U 91 1SVR405664R0100 CR-U 91V 1SVR405664R1100 CR-U 61C 1SVR405665R0000 CR-U 61CV 1SVR405665R1000 CR-U 61D 1SVR405665R4000 CR-U 61DV 1SVR405665R4100 CR-U 91C 1SVR405665R0100 CR-U 91CV 1SVR405665R1100 CR-U 71 CR-U 71A CR-U 81 1SVR405666R0000 1SVR405666R1000 1SVR405666R2000 10 0.007 (0.015) CR-U T 1SVR405667R0000 10 0.014 (0.031) CR-U 41B green, A1+, A2- CR-U 41BV Spark quenching 110 V DC 110-230 V AC 24-60 V AC/DC CR-U 21 CR-U 41C green, A1+, A2- CR-U 41CV 6-24 V AC/DC 24-60 V AC/DC A1+, A2- All CR-U modules can be plugged onto sockets CR-U2S and CR-U3S. 2CDC 292 013 F0005 2CDC 292 014 F0005 Connection diagrams CR-U 41, CR-U 41B, CR-U 41C, CR-U 41V, CR-U 41BV, CR-U 41CV CR-U 61, CR-U 61E, CR-U 91, CR-U 61V, CR-U 61EV, CR-U 91V CR-U 51B, CR-U 51C CR-U 51D, 2CDC 292 017 F0005 2CDC 292 016 F0005 CR-U 21 2CDC 292 015 F0005 6-220 V DC Diode Reverse polarity protection/ free wheeling diode 2CDC 292 018 F0005 2CDC 291 004 S0011 qty kg (lb) CR-U 61C, CR-U 61D, CR-U 91C, CR-U 61CV, CR-U 61DV CR-U 91CV 5/13 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 CR-U 71, 71A, CR-U 81 CR-U Pluggable interface relays Technical data Input circuit - coil data CR-P range Rated control supply voltage US Rated frequency Make voltage (at 20 °C) Maximum voltage (at 55 °C) Break voltage Rated power Coil resistance (at 20 °C) Tolerance of coil resistance DC coils 12 V DC 24 V DC 48 V DC 110 V DC - 8.4 V DC 16.8 V DC 33.6 V DC 77 V DC 30.6 V DC 61.2 V DC 122.4 V DC 280 V DC 0.1 US 0.1 US 0.1 US 0.1 US 0.4-0.48 W 0.4-0.48 W 0.4-0.48 W 0.4-0.48 W 360 1440 5700 25200 10% 10% 10% 10% AC coils 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 19.2 V AC 38.4 V AC 88 V AC 96 V AC 184 V AC 28.8 V AC 57.6 V AC 132 V AC 144 V AC 276 V AC 0.15 US 0.15 US 0.15 US 0.15 US 0.15 US 0.75 VA 0.75 VA 0.75 VA 0.75 VA 0.75 VA 400 1550 8900 10200 38500 10% 10% 10% 10% 10% Rated frequency Make voltage (at 20 °C) Maximum voltage (at 55 °C) Break voltage Rated power Coil resistance (at 20 °C) Tolerance of coil resistance 12 V DC 24 V DC 48 V DC - 9.6 V DC 19.2 DC 38.4 V DC 13.2 V DC 26.4 V DC 52.8 V DC 0.1 US 0.1 US 0.1 US 0.9 W 0.9 W 0.9 W 160 640 2600 10% 10% 10% 60 V DC 110 V DC 125 V DC 220 V DC - 48.0 V DC 88 V DC 100 V DC 176 V DC 66.0 V DC 121 V DC 137,5 V DC 242 V DC 0.1 US 0.1 US 0.1 US 0.1 US 0.9 W 0.9 W 0.9 W 0.9 W 4000 13600 16000 54000 10% 10% 10% 10% 24 V AC 48 V AC 60 V AC 110 V AC 120 V AC 230 V AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 19.2 V AC 38.4 V AC 48.0 V AC 88 V AC 96 V AC 184 V AC 26.4 V AC 52.8 V AC 66.0 V AC 121 V AC 132 V AC 253 V AC 0.2 US 0.2 US 0.2 US 0.2 US 0.2 US 0.2 US 1.6 VA 1.6 VA 1.6 VA 1.6 VA 1.6 VA 1.6 VA 158 640 930 3450 3770 16100 10% 10% 10% 10% 10% 10% Rated frequency Make voltage (at 20 °C) Maximum voltage (at 55 °C) Break voltage Rated power Coil resistance (at 20 °C) Tolerance of coil resistance - 9.6 V DC 19.2 V DC 38.4 V DC 88.0 V DC 96.0 V DC 176.0 V DC 13.2 V DC 26.4 V DC 52.8 V DC 121.0 V DC 132.0 V DC 242.0 V DC 0.1 Us 0.1 Us 0.1 Us 0.1 Us 0.1 Us 0.1 Us 1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 1.5 W 110 430 1750 9200 11000 37000 10 % 10 % 10 % 10 % 10 % 10 % 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 2.8 VA (50 Hz) 2.5 VA (60 Hz) 75 10 % 305 10 % 475 10 % 1700 10 % 1910 10 % 7080 10 % 5 CR-M range Rated control supply voltage US DC coils AC coils CR-U range Rated control supply voltage US DC coils 12 V DC 24 V DC 48 V DC 110 V DC 125 V DC 220 V DC AC coils 24 V AC 50 / 60 Hz 19.2 V AC 26.4 V AC 0.15 Us 48 V AC 50 / 60 Hz 38.4 V AC 52.8 V AC 0.15 Us 60 V AC 50 / 60 Hz 48.0 V AC 66.0 V AC 0.15 Us 110 V AC 50 / 60 Hz 88.0 V AC 121.0 V AC 0.15 Us 120 V AC 50 / 60 Hz 96.0 V AC 132.0 V AC 0.15 Us 230 V AC 50 / 60 Hz 184.0 V AC 253.0 V AC 0.15 Us 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/14 Pluggable interface relays Technical data Type CR-P...1 CR-M...2 Output circuit(s) 11-12/14 11-12/14 21-22/24 Kind of output Relay, 1 c/o Contact material AgNi Relay, 2 c/o Relay, 2 c/o AgNi AgNi/Au 5 µm AgNi Rated operational voltage Ue (VDE 0110, IEC 60947-1) 250 V Minimum switching voltage Maximum switching voltage 11-12/14 21-22/24 5V 10 V DC 300 V DC 250 V DC AC 440 V AC CR-M...3 CR-M...4 CR-U...2 AgNi 11-12/14 21-22/24 31-32/34 41-42/44 Relay, 4 c/o AgNi AgNi/Au 5 µm 10 V 5V 5 mA 11-12/14 21-22/24 31-32/34 Relay, 3 c/o 250 V AC 11-12/14 21-22/24 31-32/34 Relay, 2 c/o Relay, 3 c/o AgNi 10 V 440 V AC 16 A 12 A 10 A 2 mA (AgNi/Au) 6A AC12 (resistive) 230 V 16 A 8A 12 A 10 A 6A 10 A current AC15 (inductive) 230 V 1.5 A 1.5 A 1.5 A 1.5 A 1A 1.5 A (IEC 60947-5-1) AC15 (inductive) 120 V 3A 5 mA (AgNi) Rated free air thermal current Ith Rated operational (UL 508) 8A 12 A 10 A 6A 10 A 2.5 A 2A 2.5 A 2.5 A 2A 2A 0.22 A DC13 (inductive) 250 V 0.1 A max. rated operational voltage Max. continuous thermal current at utilization category Max. making / breaking apparent power at utilization category Utilization category (resistive) (CSA22.2 No.14....) (UL 508; NEMA ICS-5) 10 A 16 A (Contact rating code designation) Utilization category (pilot duty) DC rating * 5 mA (AgNi) DC12 (resistive) 24 V Utilization category (pilot duty) AC rating 5 mA (AgNi) DC13 (inductive) 24 V DC13 (inductive) 120 V (Contact rating code designation) Max. rated operational voltage Max. continuous thermal current at utilization category Max. making / breaking apparent power at utilization category Utilization category (resistive) (CSA22.2 No.14....) B300 B300 - B300 300 V AC 300 V AC - 300 V AC 5A 5A 2.5 A - 5A 3600 / 360 VA 3600 / 360 VA 1800 / 180 VA - 3600/360 VA 16 A, 250 V AC 5A 8 A, 250 V AC 10 A, 250 V AC 6 A, 250 V AC 5 A, 250 V AC 10 A, 12 A, 150 V AC 10 A, 150 V AC 10 A, 150 V AC 250 V AC 10 A, 24 V DC - R300 300 V DC 1A 28 VA - 10 A, 28 V DC Maximum making (inrush) current 30 A Minimum switching power 0.3 W (AgNi), 0.05 W (AgNi/Au) 0.3 W (AgNi), 0.1 W (AgNi/Au) Maximum switching (breaking) power AC1 (resistive) Contact resistance CR-U...3 11-12/14 31-32/34 2 mA (AgNi/Au) 8A Minimum switching current 5 CR-P...2 4000 VA 24 A 2000 VA 3000 VA 20 A 2500 VA 12 A 20 A 1500 VA 2500 VA 0.3 W 100 m Maximum operating frequency rated load AC-1 without load 600 switching cycles/h 1200 switching cycles/h 72000 switching cycles/h 18000 switching cycles/h > 3 x 107 switching cycles > 0.7 x 10 5 > 10 5 switching switching cycles cycles (16 A, 250 V) (8 A, 250 V) see reduction factor F > 2 x 107 switching cycles > 10 5 switching cycles Response time typ. 7 ms typ. 13 ms (DC),10 ms (AC) typ. 18 ms (DC), 12 ms (AC) Release time typ. 3 ms typ. 3 ms (DC), 8 ms (AC) typ. 7 ms (DC), 10 ms (AC) Rated insulation voltage 400 V AC 250 V AC Insulation class C250 / B400 C250 / B250 between coil and contacts 5 kV AC 2.5 kV AC between open contacts 1 kV AC Mechanical lifetime Electrical lifetime electrical AC1 (resistive) cos ϕ (12 A, 250 V) (10 A, 250 V) 12000 switching cycles/h (6 A, 250 V) > 10 5 switching cycles (10 A, 250 V) Isolation data Rated impulse withstand voltage Uimp between c/o (SPDT) contacts - C250 1.5 kV AC 2.5 kV AC 2.5 kV AC * Those ratings are based on different type tests but they are not covered by the cULus or CSA approvals. 5/15 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 2 kV AC 2 kV AC Pluggable interface relays Technical data, Load limit curves Type CR-P...1 Clearance between coil and contacts 10 mm Creepage distance between coil and contacts CR-P...2 CR-M...2 CR-M...3 2.5 mm CR-M...4 CR-U...2 1.6 mm 3 mm CR-U...3 10 mm 4 mm 3.2 mm 4.2 mm Overvoltage category III III II III Pollution degree 3 3 2 3 Dimensions (W x H x D) when mounted 12.7 x 29 x 15.7 mm 21.2 x 27.5 x 35.6 mm 35 x 35 x 54.4 mm Weight 14 g (0.031 lb) 35 g (0.077 lb) 83 g (0.18 lb) Mounting on socket (see accessories) Mounting position any Degree of protection IP 67 General data IP 40 Electrical connection Connection by socket 5 Environmental data Ambient temperature range operation storage Vibration resistance 10-150 Hz Shock resistance DC: -40...+85 °; AC: -40...+70 °C DC: -40...+70 °; AC: -40...+55 °C -40 ... +85 °C n/o contact 10 g n/c contact 10 g 5g 5g 5g 5g 5g n/o contact 30 g 20 g 10 g 10 g n/c contact 30 g 20 g 5g 10 g EN 60810-1, EN 60255-23, IEC 61810-7 EN 60255-1-00 Standards Product standard EN 61810-1, EN 60255-23 IEC 60664-1 Low Voltage Directive 2006/95/EC Approvals see page 5/6. Load limit curves - Maximum switching power at resistive DC load CR-U with 2 and 3 c/o contacts DC current [A] CR-M with 4 c/o contacts 2 = inductive load, T = 40 ms DC voltage [V] DC voltage [V] 2CDC 292 023 F0204 1 = resistive load, T = 0 ms 2CDC 292 019 F0204 2CDC 292 015 F0204 DC current [A] DC voltage [V] DC voltage [V] DC current [A] CR-M with 3 c/o contacts DC current [A] CR-M with 2 c/o contacts DC voltage [V] 2 = inductive load, T = 40 ms 2CDC 292 010 F0204 2CDC 292 005 F0204 DC current [A] DC voltage [V] 1 = resistive load, T = 0 ms 2CDC 292 028 F0204 CR-P with 2 c/o contacts DC current [A] CR-P with 1 c/o contact 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/16 Pluggable interface relays Load limit curves Load limit curves - Electrical lifetime at resistive AC load CR-P with 2 c/o contacts CR-M with 4 c/o contacts Switching power [kVA] 2CDC 292 022 F0204 Switching power [kVA] 2CDC 292 018 F0204 Switching cycles Switching cycles 2CDC 292 013 F0204 Switching power [kVA] Switching power [kVA] 2CDC 292 027 F0204 Switching cycles CR-M with 3 c/o contacts Switching cycles CR-M with 2 c/o contacts Switching power [kVA] 2CDC 292 009 F0204 2CDC 292 003 F0204 Switching power [kVA] 5 CR-U with 2 and 3 c/o contacts Switching cycles Switching cycles CR-P with 1 c/o contact Reduction factor F at inductive AC load CR-U 5/17 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Power factor 2CDC 292 029 F0204 Power factor 2CDC 292 014 F0204 Power factor 2CDC 292 004 F0204 Reduction factor Reduction factor CR-M Reduction factor CR-P Pluggable interface relays Connection diagrams CR-P with 1 c/o contact CR-M with 2 c/o contacts 2CDC 292 024 F0004 2CDC 292 016 F0004 2CDC 292 011 F0004 2CDC 292 001 F0004 Connection diagrams CR-M with 3 c/o contacts CR-U with 2 c/o contacts CR-P with 2 c/o contacts 2CDC 292 030 F0004 2CDC 292 008 F0004 2CDC 292 020 F0004 5 CR-M with 4 c/o contacts CR-U with 3 c/o contacts Dimensional drawings 2CDC 292 002 F0004 2CDC 292 012 F0004 2CDC 292 025 F0004 Dimensions in mm and inches CR-U with 2 c/o contacts CR-M with 2 c/o contacts 2CDC 292 017 F0004 2CDC 292 026 F0004 CR-P CR-U with 3 c/o contacts 2CDC 292 021 F0004 CR-M with 3 c/o contacts 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/18 Pluggable interface relays Connection diagrams Dimensional drawings Dimensions in mm and inches Sockets for screw connection Marker 62 Marker 42,6 27,2 27,2 27,2 24 51,2 15,8 7,5 Relay 76 20 2CDC 292 006 F0211 35,4 Pluggable function module CR-M2SS - CR-M3SS - CR-M4SS Holder Pluggable function module 60,8 27,2 Marker 27,2 42,6 27,2 24 CR-PLS 2CDC 292 003 F0211 61 3.2 CR-M3LS CR-M2LS - CR-M3LS - CR-M4LS 78.5 50 75,3 75,3 9 - M3 4 29,8 29,8 CR-U2S CR-PLSx CR-U3S CR-U2S - CR-U3S 2CDC 292 081 F0004 Marker 42.8 CR-U3E Holder 76 10 35,4 24 12 - M3 2CDC 292 008 F0011 Pluggable function module 15.5 24 11 - M3 61,8 CR-U2SM CR-PSS 5/19 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 26 27,8 8 - M3 61,8 2CDC 292 009 F0011 Pluggable function module 38,1 38,1 27,8 CR-U3SM CR-U2SM 4 2CDC 292 002 F0005 Relay 35,4 20 38,1 Holder 7.62 15,8 Pluggable function module 29,1 CR-M4LS 37,3 29.4 2CDC 292 033 F0004 CR-M2LS Holder Relay 5.08 20.32 5.08 42.5 35,4 75 Relay 62 2CDC 292 007 F0211 5 Relay Holder 2CDC 292 004 F0211 10 75,2 29 CR-U3SM Pluggable interface relays Connection diagrams Dimensional drawings Dimensions in mm and inches Sockets for spring connection 43,5 42,5 33,8 7,62 33,2 31 24 95 16,3 27 26 34,4 79,5 CR-PLC 2CDC 292 006 F0005 5,5 25,9 20,32 5,08 97,5 2CDC 292 010 F0011 5,08 15 12,4 12,4 24,4 5 CR-M2LC , CR-M4LC Jumper 2±0,2 6±0,2 1 9,5 10 R1 2CDC 292 011 F0011 9 x 27.2 (=244,8) 27.2 ±0.2 246.8 CR-PJ ±0,2 2±0,2 R1 1,5 10 10 6±0,2 2CDC 292 012 F0011 9x15 (=139,5) 15,5 141,5+1 CR-MJ 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/20 Interface relays and optocouplers R500 / R600 range Product group picture 5 5/21 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays and optocouplers R500 / R600 range Table of contents Interface relays and optocouplers R500/R600 range Table of contents 5/22 Benefits and advantages 5/23 Type designators 5/24 Interface relays and optocouplers R500 range 5/25 Table of contents 5/26 Interface relays R500 range 5/27 Table of contents 5/28 Selection 5/29 Ordering details 5/30 Technical information 5/31 Notes 5/32 Optocouplers R500 range 5/33 Table of contents 5/34 Selection 5/35 Ordering details 5/36 Connection diagrams 5/37 Technical data 5/38 Interface relays and optocouplers R600 range 5/45 Table of contents 5/46 Interface relays R600 range 5/47 Table of contents 5/48 Benefits and advantages 5/49 Selection 5/51 Ordering details 5/53 Connection diagrams 5/55 Technical data 5/56 General technical data 5/61 Dimensional drawings, Load limit curves 5/62 Optocouplers R600 range 5/63 Table of contents 5/64 Selection 5/65 Ordering details 5/67 Connection diagrams 5/68 Technical data 5/69 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/22 5 5 2CDC 291 024 F0013 2CDC 291 002 F0013 Interface relays and optocouplers R500 / R600 range Benefits and advantages R500 series R600 series It is our range offering pluggable functions Standard range in screw clamp or spring clamp versions Spacing : 5.08 mm (the smallest in the market) Wire size : 2.5 mm² (4 mm² solid) Contact type : 1 SPDT from 10 mA to 6 A / 250 V Spacing : 6 mm or 12 mm Wire size : 2.5 mm² (4 mm² solid wire) Contact type : 1 NO, 1 NC, 1 SPDT, 1 DPDT from 1 mA to 8 A / 250 V In today’s automation systems, PLCs are the core of industry. They link sensors and actuators to the process, which are connected to the PLC via conventional wires. However these PLCs are not completely isolated from the industrial environment, hence over voltage picks and transient currents can affect their operating functions. And additionally, their application field is often limited to 24 VDC / 100 mA. So, with the aim to adapt application voltage and/or current and provide as well the right electrical isolation to the PLC, it is recommended to install per I/O the right interface providing both voltage-current level adaptation and isolation protection. This interfacing is possible thanks to ABB’s relays and optocouplers ranges, which offer wide adaptation in both voltage (from 5 to 400 V) and current (from 10-7 to 16 A) as well as high isolation between input and output from 2 to 4 KV. 5/23 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays and optocouplers R500 / R600 range Type designators SERIES CODE NB OF RELAYS CONTACT TYPE NB OF CONTACTS PER RELAY R 600 R B R 600 R B PARTICULARITIES R R 500 D 2,5/5 R 0 None 1 1 1 A 2 2 B R I 5 Features Description of contact types None A 0 1 Normally Closed 1 NC 1 1 Normally Open 1 NO 2 1 Change Over or Single Pole Double Through Input voltage Input voltage DC AC/DC R RC circuit protection : - Input protection against leakage current - Increases relay contacts life Switch to force the coil for maintenance and/or installation I purposes Auto A1 off Manu A3 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/24 Interface relays and optocouplers R500 range Product group picture 5 5/25 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays and optocouplers R500 range Table of contents Interface relays and optocouplers R500 range Product group picture 5/25 Table of contents 5/26 Interface relays R500 range 5/27 Product group picture 5/27 Table of contents 5/28 Selection 5/29 Ordering details 5/30 Technical information 5/31 Optocouplers R500 range 5/33 Product group picture 5/33 Table of contents 5/34 Selection 5/35 Ordering details 5/36 Connection diagrams 5/37 Technical data 5/38 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/26 5 Interface relays R500 range Product group picture 5 5/27 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays R500 range Table of contents Interface relays R500 range Table of contents 5/28 Selection 5/29 Ordering details 5/30 Technical information 5/31 Notes 5/32 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/28 1SNA 645 047 R0000 1SNA 645 547 R0200 D 2,5/5-R121AL-48VAC/DC 1SNA 645 521 R2000 1SNA 645 549 R1400 D 2,5/5-R121L-24VDC D 2,5/5-R121AL-24VAC/DC 1SNA 645 021 R2600 1SNA 645 049 R1200 D 2,5/5-R121-24VDC D 2,5/5-R121BL-110VAC D 2,5/5-R121BL-230VAC 1 1 1 1 1 1 Input voltage 24 V DC 2CDC 291 015 F0011 Order number 5 Type Interface relays R500 range Selection R500 series Characteristics Spacing : 5.08 mm (the smallest in the market) Wire size : 2.5 mm² (4 mm² solid) Contact type : 1 SPDT from 10 mA to 6 A / 250 V 48 V DC 24 V AC 48 V AC 110 V AC 230 V AC Output rating 10 mA - 6 A Output contacts c/o Type with LED without LED 5/29 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays R500 range Ordering details Description of R500 Relay Type Relay module 1 SPDT high level Order code Price D 2,5/5-R121-24VDC 1SNA607217R0200 D 2,5/5-R121L-24VDC 1SNA607201R1300 0.032 (0.071) 2CDC 291 015 F0011 D 2,5/5-R121AL-24VAC/DC 1SNA607231R0000 Relay module with LED 1 SPDT high level D 2,5/5-R121AL-48VAC/DC 1SNA607232R0100 R500 Accessories D 2,5/5-R121BL-110VAC 1SNA607264R1100 D 2,5/5-R121BL-230VAC 1SNA607265R1200 Type Order code BAMH High end stop 9,1 mm 1SNA114836R0000 BAMH V0 9,1 mm 1SNA194836R0100 BADH 1SNA116900R2700 12 mm Comb type jumper bar 2 to 22 poles BNMS R24V-... BAMH DCB FC2 PCMS BADH 0.04 (0.088) Pkg Weight qty (1 pce) kg (lb) 50 consult us Jumper bar 10 poles grey PCMS V0 1SNA205523R2200 Relay / Opto base D 2,5/5-MP 1SNA607224R0100 Relay / Opto base with LED 24 VDC D 2,5/5-MP-24VDC 1SNA607222R0700 Relay / Opto base with LED 24 VAC/VDC D 2,5/5-MP-24VAC/DC 1SNA607260R2100 Relay / Opto base with LED 48 VAC/VDC D 2,5/5-MP-48VAC/DC 1SNA607261R1600 Relay / Opto base with LED 110 VAC D 2,5/5-MP-110VAC 1SNA607266R1300 Relay / Opto base with LED 230 VAC D 2,5/5-MP-230VAC 1SNA607267R1400 Plug relay 24 V 1 SPDT 10 mA to 6 A BNMS R24V-1 1SNA031820R1400 Plug relay 24 V 1 SPDT 1 mA to 6 A BNMS R24V-2 1SNA031847R1300 Test device blue DCB 1) 1SNA105028R2100 Test plug DIA. 2 mm FC2 1SNA007865R2600 Marking method RC55 see marking 1) 10 Price R500 Pkg Weight qty (1 pce) kg (lb) 8 0.028 (0.062) 10 0.036 (0.0794) 4 10 Only on top decks D2,5/5-MP... Connection diagrams D 2,5/5-R121 D 2,5/5-R121L D 2,5/5-R121AL-48V D 2,5/5-R121BL D 2,5/5-R121AL-24V 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/30 5 Interface relays R500 range Technical information Technical data Relay : 1 SPDT high level with contact 10 mA to 6 A - 5.08mm 0.200“ spacing D 2.5/5-R121 D 2.5/5-R121L D 2.5/5-R121AL D 2.5/5-R121BL Relay characteristics coil Rated voltage: +20%, -15% on DC ; 10%, -10% on AC 24 V DC 24 V DC Frequency 24 V DC 48 V AC 48 V DC 50/60 Hz 110 V AC 230 V AC 50/60 Hz 50/60 Hz Power 0.17 W 0.3 W 0.35 W 0.35 W 0.44 W 0.47 W 1.08 W 2.13 W Rated current 7 mA 12 mA 12.4 mA 10 mA 7.6 mA 6.8 mA 8.4 mA 8 mA Drop-out voltage at 20°C 2.4 V 2.4 V 4.8 V 4.8 V 10 V 10 V 25 V 45 V Status device green LED Relay characteristics contact Type 1 SPDT Voltage switching range min./max. 12 V / 250 V AC Current switching range min./max. 10 mA / 6 A AC1 min./max. 0.6 VA / 1500 VA (ohmic load) Load switching range DC1 min./max. 0.6 W / 140 W Number of on-load operations 10 5 on AC15 Number of off-load operations 10 x 107 Operation speed F 5 ms 5 ms 5 ms 5 ms 5 ms 5 ms 6 ms 7 ms O 8 ms 8 ms 15 ms 15 ms 15 ms 15 ms 15 ms 15 ms Insulation coil / contact 4000 V RMS Resistance to shock coil / contact 4000 V RMS Insulation contact / contact Ambient temperature 1000 V RMS storage -40 °C to -80 °C operating See derating curves Other characteristics Body material grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Wire size Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 10 mm (0.394 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending) , Reference standards 24 V 110/120 V 220/230 V CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. DC12 AC12 DC13 AC15 6 A 6 A 1 A 3A 0,3 A 6 A 0,2 A 3A 0,2 A 6 A 0,1 A 3A Dimensional drawings Voltage (Vcc) 5 24 V AC 50/60 Hz 1 : 24 V 2 : 48 V 3 : 110 V 4 : 230 V Current (Acc) D 2,5/5-R121 5/31 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays R500 range Notes 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/32 Optocouplers R500 range Product group picture 5 5/33 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Optocouplers R500 range Table of contents Optocouplers R500 range Product group picture 5/33 Table of contents 5/34 Selection 5/35 Ordering details 5/36 Connection diagrams 5/37 Technical data 5/38 Notes 5/44 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/34 1SNA 607 274 R1300 1SNA 607 210 R1700 1SNA 607 211 R0400 1SNA 607 275 R1400 1SNA 607 212 R0500 1SNA 607 213 R0600 1SNA 607 214 R0700 1SNA 607 215 R0000 1SNA 607 203 R1500 1SNA 607 204 R1600 1SNA 607 205 R1700 1SNA 607 206 R1000 1SNA 607 207 R1100 D 2,5/5-OBIC-0030-24VDC D 2,5/5-OBIC-0030-48VDC D 2,5/5-OBIC-0030-125VDC D 2,5/5-OBIA-0030-24VAC D 2,5/5-OBIA-0030-48VAC D 2,5/5-OBIA-0030-115VAC D 2,5/5-OBIA-0030-230VAC D 2,5/5-OBOC-0100-5VDC D 2,5/5-OBOC-0100-24VDC D 2,5/5-OBOC-0100-48VDC D 2,5/5-OBOC-1000-5VDC D 2,5/5-OBOC-1000-24VDC Input voltage 5 V DC 24 V DC 48 V DC 125 V DC 24 V AC 48 V AC 110 V AC 115 V AC 230 V AC Output rating 30 mA 100 mA 2A 1A Output voltage 30 V DC 58 V DC 253 V AC Type input optocoupler output optocoupler 5/35 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 1SNA 607 271 R1000 1SNA 607 208 R2200 1SNA 607 209 R2300 D 2,5/5-OBOC-1000-230VAC D 2,5/5-OBOC-2000-5VDC D 2,5/5-OBOC-2000-24VDC 1SNA 607 272 R1100 1SNA 607 273 R1200 1SNA 607 238 R1700 1SNA 607 240 R2500 1SNA 607 241 R1200 1SNA 607 268 R2500 1SNA 607 269 R2600 D 2,5/5-OBOC-2000-110VAC D 2,5/5-OBOC-2000-230VAC D 2,5/5-OBOA-1000-24VDC D 2,5/5-OBOA-1000-24VAC/DC D 2,5/5-OBOA-1000-48VAC/DC D 2,5/5-OBOA-1000-110VAC D 2,5/5-OBOA-1000-230VAC D 2,5/5-OBOC-2000-48VAC/DC 1SNA 607 256 R1100 D 2,5/5-OBOC-2000-24VAC/DC 1SNA 607 255 R1000 1SNA 607 270 R2300 D 2,5/5-OBOC-1000-110VAC D 2,5/5-OBOC-1000-48VAC/DC 1SNA 607 251 R1400 D 2,5/5-OBOC-1000-24VAC/DC 1SNA 607 250 R2700 Order number D 2,5/5-OBIC-0030-5VDC 5 Type Optocouplers R500 range Selection Optocouplers R500 range Ordering details Description of R600 Optocoupler Type 2CDC 291 002 F0013 Optocoupler module 30 mA/DC Transistor Optocoupler module 30 mA/DC Transistor Optocoupler module 100 mA/DC Transistor Optocoupler module 1 A/DC MOS-FET D 2,5/5-OBIC-0030-5VDC 1SNA607274R1300 D 2,5/5-OBIC-0030-24VDC 1SNA607210R1700 D 2,5/5-OBIC-0030-48VDC 1SNA607211R0400 D 2,5/5-OBIC-0030-125VDC 1SNA607275R1400 D 2,5/5-OBIA-0030-24VAC 1SNA607212R0500 D 2,5/5-OBIA-0030-48VAC 1SNA607213R0600 D 2,5/5-OBIA-0030-115VAC 1SNA607214R0700 D 2,5/5-OBIA-0030-230VAC 1SNA607215R0000 D 2,5/5-OBOC-0100-5VAC 1SNA607203R1500 D 2,5/5-OBOC-0100-24VDC 1SNA607204R1600 D 2,5/5-OBOC-0100-48VAC 1SNA607205R1700 D 2,5/5-OBOC-1000-5VDC 1SNA607206R1000 D 2,5/5-OBOC-1000-24VDC 1SNA607207R1100 Optocoupler module 1 A/AC Thyristor BNMS P... 1SNA607271R1000 D 2,5/5-OBOC-2000-5VDC 1SNA607208R2200 D 2,5/5-OBOC-2000-24VDC 1SNA607209R2300 D 2,5/5-OBOC-2000-24VAC/DC 1SNA607255R1000 D 2,5/5-OBOC-2000-48VAC/DC 1SNA607256R1100 D 2,5/5-OBOC-2000-110VAC 1SNA607272R1100 D 2,5/5-OBOC-2000-230VAC 1SNA607273R1200 D 2,5/5-OBOA-1000-24VDC 1SNA607238R1700 D 2,5/5-OBOA-1000-24VAC/DC BAMH PCMS BADH 0.032 (0.071) 1 0.032 (0.071) 1 0.032 (0.071) 1 0.04 (0.088) 1 0.04 (0.088) 1SNA607240R2500 0.032 (0.071) 1 D 2,5/5-OBOA-1000-48VAC/DC 1SNA607241R1200 D 2,5/5-OBOA-1000-110VAC 1SNA607268R2500 D 2,5/5-OBOA-1000-230VAC 1SNA607269R2600 Type Order code BAMH 9.1 mm 1SNA114836R0000 BAMH V0 9.1 mm 1SNA194836R0100 BADH 12 mm 1SNA116900R2700 Comb type jumper bar 2 to 22 poles 1 1SNA607270R2300 D 2,5/5-OBOC-1000-230VAC Description of Accessories Pkg Weight qty (1 pce) kg (lb) 5 D 2,5/5-OBOC-1000-48VAC/DC 1SNA607251R1400 High end stop D2,5/5-MP... Price D 2,5/5-OBOC-1000-24VAC/DC 1SNA607250R2700 D 2,5/5-OBOC-1000-110VAC Optocoupler module 2 A/DC MOS-FET Order code Price 0.04 (0.088) Pkg Weight qty (1 pce) kg (lb) 50 consult us Jumper bar 10 poles grey PCMS V0 1SNA205523R2200 8 Input opto base D 2.5-5-MP1 1SNA607223R0000 10 Plug OBIC 5 V white BNMS T5V-1 1SNA031831R0300 Plug OBIC 24 V white BNMS T24V-1 1SNA031800R2100 Plug OBIC 48 V white BNMS T48V-1 1SNA031801R1600 Plug OBIC 125 V white BNMS T125V-1 1SNA031845R1100 Test device blue DCB (1) 1SNA105028R2100 Test plug DIA 2 mm FC2 1SNA105028R2100 Marking method RC55 see marking 0.028 (0.062) 4 10 FC2 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/36 Optocouplers R500 range Connection diagrams IN IN D 2,5/5-OBIA-0030 D 2,5/5-OBIC-0030 5 IN D 2,5/5-OBOC-0100 IN IN D 2,5/5-OBOC-1000 24/48 VAC/DC 110/230 VAC D 2,5/5-OBOC-1000 5/24 VDC IN D 2,5/5-OBOA-1000 5/37 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 IN D 2,5/5-OBOC-2000 Optocouplers R500 range Technical data Technical data Pluggable optocoupler : 5 to 58 V DC output / 30 mA - 5.08 mm 0.200“ spacing D 2,5/5-OBIC-0030 Input Input voltage 4.5 V to 5.5 VDC 19.2 V to 27.6 VDC 38.4 V to 55.2 VDC 93.5 V to 140 VDC Input current 6 mA 5 mA 4.1 mA 3 mA Pull-in voltage at Is=100% 3.5 V 12 V 21 V 50 V Switching time C / O 20 µs / 1.3 ms Operating frequency 400 Hz 1 mA 0.8 mA Permissible leakage current Output Output voltage 4.5 to 58 V DC Output current min. 0.5 mA Output current max. 30 mA Output leakage current at Umax. Redidual voltage at I max and U rated 5 < 50 µA typical 2.3 V DC max 2.7 V DC Frequency on inductive load Isolation Input / Output Ambient temperature input / Output 2500 V RMS storage -40...+80 °C operating See derating curve Other characteristics Body material Wire size grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals Reference standards (pending), CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Derating curve Dimensional drawings 1 : 5 V - 24 V - 48 V 2 : 115 V A1 D 2,5/5-OBIC-0030 14 A2 13 center of rail 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/38 Optocouplers R500 range Technical data Technical data Pluggable optocoupler : 5 to 58 V DC output / 30 mA - 5.08 mm 0.200“ spacing D 2,5/5-OBIA-0030 Input Input voltage 5 20.4 to 26.4 V AC 40.8 V to 52.8 V AC 98 V to 126.5 V AC 195.5 V to 253 V AC 50 / 60 Hz 50 Hz Input current 8.5 mA 4.5 mA 8 mA 7 mA Pull-in voltage at Is=100% 13 V 22 V 50 V 95 V Switching time C / O 6 ms / 10 ms Operating frequency 30 Hz Permissible leakage current 1 mA 2 mA Output Output voltage 4.5 V to 58 V DC Output current min. 0.5 mA Output current max. 30 mA Output leakage current at Umax. Redidual voltage at I max and U rated < 50 µA typical 2.3 V DC max 2.7 V DC Frequency on inductive load Isolation Input / Output 2500 V RMS input / Output Temperature Ambient temperature storage -40...+80 °C operating See derating curve Other characteristics Body material Wire size grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), Reference standards CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Dimensional drawings Derating curve 1 : 24 V - 48 V 2 : 115 V - 230 V A1 D 2,5/5-OBIA-0030 14 13 center of rail 5/39 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 A2 Optocouplers R500 range Technical data Technical data Pluggable optocoupler : 5 to 58 V DC output / 100 mA - 5.08 mm 0.200“ spacing D 2,5/5-OBOC-0100 5 V DC / 24 V DC D 2,5/5-OBOC-0100 48 V DC Input Input voltage 4.5 V to 5.5 V DC 20.4 V to 28.8 V DC 40.8 V to 57.6 V DC Input current 8.5 mA 4.8 mA 3.9 mA Pull-in voltage at Is=100% 2.9 V DC 16 V DC 26 V DC Switching time C / O 20 µs / 1.3 ms Operating frequency 400 Hz Permissible leakage current 1 mA Frequency 5 Output Output voltage 4.5 V to 58 V DC Output current min. 1 mA Output current max. 100 mA Output leakage current at Umax. < 50 µA Redidual voltage at I max and U rated typical 1 V DC max 1.3 V DC Frequency on inductive load See Note 1 Isolation Input / Output input / Output 2500 V RMS Temperature storage -40...+80 °C Ambient temperature operating See derating curve Other characteristics Body material grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Wire size Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), Reference standards CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Note 1 : or Fmax = (1-0,007 x Us) / (L x Is²) Fmax = (1-0,007 x Us) / (P x L ) R Us Is L P R = Output voltage = Output current = Inductance of load = Power of load = Resistance of load Dimensional drawings A1 Derating curve 14 A2 13 center of rail D 2,5/5-OBOC-0100 5 V DC / 24 V DC D 2,5/5-OBOC-0100 48 V DC 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/40 Optocouplers R500 range Technical data Technical data Pluggable optocoupler : 5 to 58 V DC output / 1 A - 5.08 mm 0.200“ spacing D 2,5/5-OBOC-1000 D 2,5/5-OBOC-1000 24/48 V AC/DC 5/24 V DC Input 5 V DC 24 V DC Input voltage 4.5 - 5.5 V DC Input current 24 V AC 24 V DC 20.4 - 28.8 V DC 24 ± 10 % 12.3 mA 6.7 mA Pull-in voltage at Is=100% 3.5 V DC 10 V DC Switching time C / O 20 / 250 µs Operating frequency 2000 Hz 110/230 V AC 48 V AC 48 V DC 20.4 - 28.8 V DC 48 ± 10 % 40.8 to 57.6 110 ± 10 % V DC 50 / 60 Hz 50 / 60 Hz 10.5 mA 8 mA 6.8 mA 5.8 mA 8.5 mA 7.5 mA 50 / 350 µs 15 / 13 ms 5 / 13 ms 15 / 15 ms 6 / 25 ms 15 / 15 ms 15 / 15 ms 1500 Hz 20 Hz Frequency 5 D 2,5/5-OBOC-1000 50 / 60 Hz 50 / 60 Hz 110 V AC 230 V AC 230 ± 10 % Permissible leakage current Output Output voltage 4.5 V to 58 V DC Output current min. 1 mA Output current max. 1A Output leakage current at Umax. < 50 µA Redidual voltage at I max and U rated typical 0.1 V DC max 0.5 V DC Frequency on inductive load See Note 1 Isolation Input / Output input / Output 2500 V RMS Temperature storage -40...+80 °C Ambient temperature operating See derating curve Other characteristics Body material grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Wire size Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 10 mm (0.394 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), Reference standards CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Note 1 : or Fmax = (1-0,007 x Us) / (L x Is²) Fmax = (1-0,007 x Us) / (P x L ) R Us Is L P R = Output voltage = Output current = Inductance of load = Power of load = Resistance of load Dimensional drawings 14 Derating curve A1 A2 center of rail 5/41 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 13+ Optocouplers R500 range Technical data Technical data Pluggable optocoupler : 5 to 30 V DC output / 2 A - 5.08 mm 0.200“ spacing D 2,5/5-OBOC-2000 D 2,5/5-OBOC-2000 24/48 V AC/DC 5/24 V DC Input 5 V DC 24 V DC Input voltage 4.5 - 5.5 V DC Input current 24 V AC 24 V DC 20.4 - 28.8 V DC 24 ± 10 % 12.3 mA 6.7 mA Pull-in voltage at Is=100% 3.5 V DC 10 V DC Switching time C / O 20 / 250 µs Operating frequency 2000 Hz D 2,5/5-OBOC-2000 110/230 V AC 48 V AC 48 V DC 20.4 - 28.8 V DC 48 ± 10 % 40.8 to 57.6 110 ± 10 % V DC 50 / 60 Hz 50 / 60 Hz 10.5 mA 8 mA 6.8 mA 5.8 mA 8.5 mA 7.5 mA 50 / 350 µs 15 / 13 ms 5 / 13 ms 15 / 15 ms 6 / 25 ms 15 / 15 ms 15 / 15 ms 1500 Hz 20 Hz Frequency 50 / 60 Hz 50 / 60 Hz 110 V AC 230 V AC 230 ± 10 % 5 Permissible leakage current Output Output voltage 4.5 V to 30 V DC Output current min. 1 mA Output current max. 2A Output leakage current at Umax. < 50 µA Redidual voltage at I max and U rated typical 0.1 V DC max 0.5 V DC Frequency on inductive load See Note 1 Isolation Input / Output input / Output 2500 V RMS Temperature storage -40...+80 °C Ambient temperature operating See derating curve Other characteristics Body material grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Wire size Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 10 mm (0.394 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), Reference standards CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Note 1 : or Fmax = (1-0,012 x Us) / (L x Is²) Fmax = (1-0,012 x Us) / (P x L ) R Us Is L P R = Output voltage = Output current = Inductance of load = Power of load = Resistance of load Dimensional drawings 14 Derating curve 13+ center of rail 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/42 Optocouplers R500 range Technical data Technical data Pluggable optocoupler : 24 to 253 V AC output / 1 A - 5.08 mm 0.200“ spacing D 2,5/5-... D 2,5/5-OBOA-1000 24 V AC/DC - 48 V AC/DC 24 V DC Input 24 V DC Input voltage 20.4 - 28.8 V DC Frequency 24 V AC 24 V DC 24 ± 10 % 20.6 - 28.8 V DC 50 / 60 Hz D 2,5/5-OBOA-1000 110 V AC - 230 V AC 48 V AC 48 V DC 110 V AC 230 V AC 48 ± 10 % 40.8 -57.6 V DC 110 ± 10 % 230 ± 10 % 50 / 60 Hz 50 / 60 Hz 4 mA 10 mA 7 mA 6 mA 5 mA 8 mA 7.5 mA Switching time C / O 10/20 ms 20/20 ms 10/20 ms 20/20 ms 10/20 ms 20/20 ms 20/20 ms Operating frequency 15 Hz Input current 50 / 60 Hz Pull-in voltage at Is=100% 5 Permissible leakage current Output Output voltage 24-253 V AC - 50/60 Hz Output current min. 25 mA Output current max. 1A Output leakage current at Umax. < 0.50 mA typical 1 V Redidual voltage at I max and U rated max 1.6 V Frequency on inductive load See Note 1 Isolation Input / Output input / Output 2500 V RMS Temperature storage -40...+80 °C Ambient temperature operating See derating curve Other characteristics Body material grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Wire size Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 10 mm (0.394 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), Reference standards CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Note 1 : or Fmax = (1-0,012 x Us) / (L x Is²) Fmax = (1-0,012 x Us) / (P x L ) R Us Is L P R = Output voltage = Output current = Inductance of load = Power of load = Resistance of load Dimensional drawings Derating curve 14 A1 A2 center of rail 5/43 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 13+ Optocouplers R500 range Notes 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/44 Interface relays and optocouplers R600 range Product group picture 5 5/45 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays and optocouplers R600 range Table of contents Interface relays and optocouplers R600 range Product group picture 5/45 Table of contents 5/46 Interface relays R600 range 5/47 Product group picture 5/47 Table of contents 5/48 Benefits and advantages 5/49 Selection 5/51 Ordering details 5/53 Connection diagrams 5/55 Technical data 5/56 General technical data 5/61 Dimensional drawings, Load limit curves 5/62 Optocouplers R600 range 5/63 Product group picture 5/63 Table of contents 5/64 Selection 5/65 Ordering details 5/67 Connection diagrams 5/68 Technical data 5/69 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/46 5 Interface relays R600 range Product group picture 5 5/47 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays R600 range Table of contents Interface relays R600 range Product group picture 5/47 Table of contents 5/48 Benefits and advantages 5/49 Selection 5/51 Ordering details 5/53 Connection diagrams 5/55 Technical data 5/56 General technical data 5/61 Dimensional drawings, Load limit curves 5/62 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/48 Interface relays R600 range Benefits and advantages Characteristics 5 Standard range available with screw or spring-type terminals 8 different rated control supply voltages: DC versions: 5 V, 12 V, 24 V AC/DC versions: 24 V, 48-60 V, 115 V, 230 V, 60-230 V Output: 1 n/c contact, 1 n/o contact, 1 c/o (SPDT) contact, 2 c/o (SPDT) contacts Devices with output contacts protected by built in RC circuit, which result in increased contact life Devices with leakage current protection on the input side Available with visible or covered switch on the front of the unit, for the configuration of manual or automatic actuation With connection for jumper bar, except 2 c/o devices and some discontinued devices Width: 6 mm (0.236 in) or 12 mm (0.472 in) LED for the indication of the operational state Accessories: Jumper bars, separator end section and distribution blocks 1 1 Input - Control supply voltage 2 2 Jumper bar connection 3 Indication of operational states (green LED) 3 4 Output 4 Excellent adaption and conversion of digital signals AC 110 V DC 24 V DC 24 V AC 230V Pushbutton R 600 Relay or Position Optocoupler PLC switch Sensor AC 110 V AC 230 V R 600 Relay or Optocoupler 5/49 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 AC 380 V Motor contactor Motor Interface relays R600 range Benefits and advantages Interface relays are electromechanic and electronic input and output modules for electrical isolation, levelling, noise suppression or signal amplification between control unit and process. Boxed interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC (programmable logic controller), PC or field bus systems and the sensor / actuator level. The compact design and different connection terminal possibilities optimize your panel installation. 5 Variety of connections R600 relays and optocouplers are available with both screw terminals or spring terminals. Increased contact life The contacts of some devices are proteced by built in RC-circuits which result in increased contact life. 0.2 to 2.5 mm² 6 mm spacing 12 mm spacing 0.22 to 4 mm² Functionning status Functionning display through a green LED. Space safing With a width of only 6 mm or 12 mm the compact design safes space in each cabinet. Measurement & Test Holes for holding DIA. 2 mm test plugs to simplify any measury or test. Only one part number AC/DC Approvals H UL 508 CAN/CSA C22.2 No.14 P Lloyds Register pending Marks a CE 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/50 1SNA 645 034 R2300 1SNA 645 036 R2500 1SNA 645 534 R2500 1SNA 645 536 R2700 1SNA 645 069 R0000 1SNA 645 037 R2600 1SNA 645 537 R2000 1SNA 645 019 R0400 1SNA 645 519 R0600 1SNA 645 014 R2700 1SNA 645 063 R0000 1SNA 645 018 R0300 1SNA 645 514 R2100 1SNA 645 563 R0200 1SNA 645 518 R0500 1SNA 645 064 R0100 1SNA 645 065 R0200 1SNA 645 001 R0300 1SNA 645 005 R0700 1SNA 645 032 R2100 1SNA 645 009 R1300 1SNA 645 033 R2200 1SNA 645 010 R0700 1SNA 645 564 R0300 1SNA 645 565 R0400 1SNA 645 501 R0500 1SNA 645 505 R0100 1SNA 645 532 R2300 1SNA 645 509 R1500 1SNA 645 533 R2400 1SNA 645 510 R0100 1SNA 645 012 R2500 1SNA 645 512 R2700 RB 121-5VDC RB 121-5VDC RBR 121-5VDC RBR 121-5VDC RB 121-12VDC RB 121-12VDC RBR 121-12VDC RB 101AR-24VAC/DC RBR 101AR-24VAC/DC RB 111A-24VAC/DC RB 111AI-24VAC/DC RB 111AR-24VAC/DC RBR 111A-24VAC/DC RBR 111AI-24VAC/DC RBR 111AR-24VAC/DC RB 121-24VDC RB 121-24VDC RB 121A-24VAC/DC RB 121A-24VAC/DC RB 121AI-24VAC/DC RB 121AI-24VAC/DC RB 121AI-24VAC/DC RB 121AI-24VAC/DC RBR 121-24VDC RBR 121-24VDC RBR 121A-24VAC/DC RBR 121A-24VAC/DC RBR 121AI-24VAC/DC RBR 121AI-24VAC/DC RBR 121AI-24VAC/DC RBR 121AI-24VAC/DC RB 122A-24VAC/DC RBR 122A-24VAC/DC n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n 5 Order number Type Interface relays R600 range Selection Input voltage 5 V DC n n 12 V DC 24 V DC 48 - 60 V DC 115 V DC 230 V DC 60 - 230 V DC 24 V AC n n n n n n n n n n n n n n n n n n n n n n 48 - 60 V AC 115 V AC 230 V AC 60 - 230 V AC Output rating 10 mA - 6 A n n n n n n n n n n n n n n n n n n n 1 mA - 6 A n n n n n n n n n n n n 1 mA - 8 A n n Output contacts c/o 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 n/o 1 1 1 1 1 1 n/c 1 1 Terminal type Screw n n n n n n n n n n n n n n n n n Spring n n n n n n n n n n n n n n n n 5/51 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 1SNA 645 003 R0500 1SNA 645 007 R0100 1SNA 645 046 R0700 1SNA 645 503 R0700 1SNA 645 507 R0300 1SNA 645 546 R0100 1SNA 645 041 R0200 1SNA 645 541 R0400 1SNA 645 016 R2100 1SNA 645 516 R2300 1SNA 645 017 R2200 1SNA 645 517 R2400 1SNA 645 004 R0400 1SNA 645 008 R1200 1SNA 645 011 R2400 1SNA 645 504 R0000 1SNA 645 508 R1400 1SNA 645 511 R2600 RB 121A-115VAC/DC RB 121A-115VAC/DC RB 121AR-115VAC/DC RBR 121A-115VAC/DC RBR 121A-115VAC/DC RBR 121AR-115VAC/DC RB 122A-115VAC/DC RBR 122A-115VAC/DC RB 111A-115VAC/DC RBR 111A-115VAC/DC RB 111A-230VAC/DC RBR 111A-230VAC/DC RB 121A-230VAC/DC RB 121A-230VAC/DC RB 121AR-230VAC/DC RBR 121A-230VAC/DC RBR 121A-230VAC/DC RBR 121AR-230VAC/DC n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n 1SNA 645 520 R0300 1SNA 645 540 R1700 RBR 122A-48-60VAC/DC n 1SNA 645 020 R0100 1SNA 645 040 R1500 RB 122A-48-60VAC/DC n RBR 121A 60-230VUC 1SNA 645 506 R0200 RBR 121A-48-60VAC/DC n RB 121A 60-230VUC 1SNA 645 502 R0600 RBR 121A-48-60VAC/DC n 1SNA 645 513 R2000 1SNA 645 006 R0000 RB 121A-48-60VAC/DC n 1SNA 645 013 R2600 1SNA 645 002 R0400 RB 121A-48-60VAC/DC n RBR 122A-230VAC/DC 1SNA 645 515 R2200 RBR 111A-48-60VAC/DC RB 122A-230VAC/DC 1SNA 645 015 R2000 RB 111A-48-60VAC/DC Interface relays R600 range Selection n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 2 1 1 n 5/52 Interface relays R600 range Ordering details 2CDC 291 024 S0013 R600 Relay 5 R600 Type Order code Relay module 1 NO high level 6 mm spacing RB 111 A-24VAC/DC RB 111 A-48-60VAC/DC RB 111 A-115VAC/DC RB 111 A-230VAC/DC 1SNA645014R2700 1SNA645015R2000 1SNA645016R2100 1SNA645017R2200 Relay mod. 1 NO high level w/safety switch 6 mm spacing RB 111 AI-24VAC/DC 1SNA645063R0000 Relay mod. 1 NO high level w/ contact protection 12 mm spacing RB 111 AR-24VAC/DC 1SNA645018R0300 Relay mod. 1 NC high level w/contact protection 12 mm spacing RB 101 AR-24VAC/DC 1SNA645019R0400 Relay module 1 NO high level 6 mm spacing RBR 111 A-24VAC/DC RBR 111 A-48-60VAC/DC RBR 111 A-115VAC/DC RBR 111 A-230VAC/DC 1SNA645514R2100 1SNA645515R2200 1SNA645516R2300 1SNA645517R2400 Relay mod. 1 NO high level w/ safety switch 6 mm spacing RBR 111 AI-24VAC/DC 1SNA645563R0200 Relay mod. 1 NO high level w/ contact protection 12 mm spacing RBR 111 AR-24VAC/DC 1SNA645518R0500 Relay mod. 1 NC high level w/contact protection 12 mm spacing RBR 101 AR-24VAC/DC 1SNA645519R0600 RB 121-5VDC RB 121-12VDC RB 121-24VDC RB 121 A-24VAC/DC RB 121 A-48-60VAC/DC RB 121 A-115VAC/DC RB 121 A-230VAC/DC RB 121-5VDC RB 121-12VDC RB 121-24VDC RB 121 A-24VAC/DC RB 121 A-48-60VAC/DC RB 121 A-115VAC/DC RB 121 A-230VAC/DC RB 121-5VDC RB 121-12VDC RB 121-24VDC RB 121 A-24VAC/DC RB 121 A-48-60VAC/DC RB 121 A-115VAC/DC RB 121 A-230VAC/DC RB 121-5VDC RB 121-12VDC RB 121-24VDC RB 121 A-24VAC/DC RB 121 A-48-60VAC/DC RB 121 A-115VAC/DC RB 121 A-230VAC/DC 1SNA645034R2300 1SNA645069R0100 1SNA645064R0100 1SNA645001R0300 1SNA645002R0400 1SNA645003R0500 1SNA645004R0400 1SNA645534R2500 1SNA645569R0000 1SNA645564R0300 1SNA645501R0500 1SNA645502R0600 1SNA645503R0700 1SNA645504R0000 1SNA645036R2500 1SNA645037R2600 1SNA645065R0200 1SNA645005R0700 1SNA645006R0000 1SNA645007R0100 1SNA645008R1200 1SNA645536R2700 1SNA645537R2000 1SNA645565R0400 1SNA645505R0100 1SNA645506R0200 1SNA645507R0300 1SNA645508R1400 Relay module 1 SPDT high level Relay module 1 SPDT high level Relay module 1 SPDT low level Relay module 1 SPDT low level 5/53 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Price Pkg Weight qty (1 pce) kg (lb) 10 0.02 (0.44) 5 0.03 (0.44) 10 0.02 (0.44) 5 0.03 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) Interface relays R600 range Ordering details R600 Relay R600 Type Relay mod. 1SPDT high level w/ leakage current protec. RB 121 AR-115VAC/DC 1SNA645046R0700 RB 121 AR-230VAC/DC 1SNA645011R2400 Relay mod. 1SPDT high level w/ large coil voltage range RB 121 A 60-230VAC/DC 1SNA645020R0100 Relay mod. 1SPDT high level with switch RB 121 AI-24VAC/DC 1SNA645032R2100 Relay mod. 1SPDT high level with safety switch RB 121 AI-24VAC/DC 1SNA645009R1300 Relay module 1SPDT low level with switch RB 121 AI-24VAC/DC 1SNA645033R2200 Relay module 1SPDT low level with safety switch RB 121 AI-24VAC/DC 1SNA645010R0700 Relay mod. 1SPDT high level w/ leakage current protec. RB 121 AR-115VAC/DC 1SNA645546R0100 RB 121 AR-230VAC/DC 1SNA645511R2600 Relay mod. 1SPDT high level w/ large coil voltage range Relay mod. 1SPDT high level with switch Relay mod. 1SPDT high level with safety switch Relay module 1SPDT low level with switch Relay module 1SPDT low level with safety switch RB 121 A 60-230VAC/DC 1SNA645520R0300 RB 121 AI-24VAC/DC 1SNA645532R2300 RB 121 AI-24VAC/DC 1SNA645509R1500 RB 121 AI-24VAC/DC 1SNA645533R2400 RB 121 AI-24VAC/DC 1SNA645510R0100 RB 122 A-24VAC/DC 1SNA645012R2500 RB 122 A-48-60VAC/DC 1SNA645040R1500 RB 122 A-115VAC/DC 1SNA645041R0200 RB 122 A-230VAC/DC 1SNA645013R2600 RBR 122 A-24VAC/DC 1SNA645512R2700 Relay module 1 DPDT low level Relay module 1 DPDT low level D 4/12-3... FC2 5 5 0.03 (0.066) 0.03 (0.066) RBR 122 A-48-60VAC/DC 1SNA645540R1700 1SNA645541R0400 1SNA645513R2000 Type Order code BADH V0 1SNA116900R2700 50 BADL V0 1SNA399903R0200 50 BAM2 V0 1SNA399967R0100 50 Seperator end section SC 612 1SNA290474R0200 10 Divisible shunt 10 poles BJ 612-10 1SNA290488R0100 10 Divisible shunt 20 poles BJ 612-20 1SNA206754R0000 10 Screw clamp distribution block sp. 12 mm D4/12-3-3 1SNA645031R2000 5 Spring clamp distribution block sp. 12 mm D4/12-3R-3R 1SNA645531R2200 5 Test plug DIA. 2 mm FC2 1SNA645531R2200 10 Marking method RC65 / RC610 see marking End section SC612 Pkg Weight qty (1 pce) kg (lb) RBR 122 A-230VAC/DC BADH BJ... Price RBR 122 A-115VAC/DC Accessories R600 BADL Order code Price Pkg Weight qty (1 pce) kg (lb) 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/54 5 Interface relays R600 range Connection diagrams A1-A2 Control supply voltage S1 Connection for jumper bar (input side) S2 Connection for jumper bar (output side) 13 13 12 A1 S2 11 RB/RBR 101 AR A1 A2 S1 S2 2CDC 292 031 F0013 A2 S1 2CDC 292 030 F0013 A1 14 RB/RBR 111 A - 24 V AC/DC A2 S1 S2 14 2CDC 292 033 F0013 11-12 n/c contact 13-14 n/o contact 11-12/14 1st c/o contact 21-22/24 2nd c/o contact RB/RBR 111 A - 48/60/115/230 V AC/DC 5 13 13 RB/RBR 111 AI 14 RB/RBR 111 AR 12 14 RB/RBR 121 - 12/24 V DC, only discontinued versions: 1SNA645069R0000 1SNA645064R0100, 1SNA645564R0300 1SNA645065R0200, 1SNA645565R0400 A1 A2 S1 S2 RB/RBR 121 A - 48/60/115/230 V AC/DC A2 S1 A1 11 S2 2CDC 292 043 F0013 A2 S1 11 RB/RBR 122 A - 115/230 V AC/DC 5/55 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 21 2CDC 292 044 F0013 A1 21 A2 S1 RB/RBR 121 AR 12 14 22 24 12 14 22 24 11 12 14 auto A1 off manu A3 RB/RBR 121 AI A1 RB/RB 122 A - 24/48/60 V AC/DC S2 RB/RBR 121 A - 24 V AC/DC 2CDC 292 041 F0013 2CDC 292 040 F0013 11 11 A2 S1 12 14 A1 A2 S1 11 RB/RBR 121 (AU) - 12/24 V DC, except: 1SNA645035R2400, 1SNA645535R2600 1SNA645037R2600, 1SNA645537R2000 see connection diagram RB...121-5VDC 12 14 S2 2CDC 292 038 F0013 2CDC 292 037 F0013 11 11 12 14 A1 A2 A2 S1 S2 RB/RBR 121 - 5 V DC, A1-A2 polarized - 12 V DC, A1-A2 polarized, i.e. only: 1SNA645035R2400, 1SNA645535R2600 1SNA645037R2600, 1SNA645537R2000 12 14 A1 S1 S1 2CDC 292 036 F0013 S2 A2 2CDC 292 039 F0013 14 A2 S1 2CDC 292 035 F0013 S2 2CDC 292 034 F0013 A2 S1 12 14 A1 A1 S2 11 2CDC 292 042 F0013 auto A1 off manu A3 Interface relays R600 range Technical data Technical data RB 111 A RB 111 AI Input circuit Rated control supply voltage Us 24 V AC/DC Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 48 V AC/DC 60 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.24 W 0.34 W 0.54 W 10 mA 7 mA 9 mA 4.5 V 8V 8V green LED V: control supply voltage applied 115 V AC/DC 0.46 W 4 mA 17 V 230 V AC/DC 24 V AC/DC -15 %, +10 % -15 %, +20 % 0.8 W 3.5 mA 27 V 0.24 W 10 mA 4.5 V Output circuit Kind of output 13-14 Rated operational voltage Ue (IEC/EN 60947-1) Minimum switching voltage Maximum switching voltage Minimum switching current Rated operational current AC12 (resistive) 230 V (IEC/EN 60947-5-1) AC15 (inductive) 230 V AC15 (inductive) 120 V DC12 (resistive) 24 V DC13 (inductive) 24 V DC13 (inductive) 120 V DC13 (inductive) 230 V AC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC15 Response time Release time Dimensions and weight Weight Dimension relay, 1 n/o contact 250 V AC 12 V 250 V AC 10 mA 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 5 R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 5 ms 8 ms 8 ms 5 ms 8 ms RB 111 A / RB 111 AI high level 6 ms 15 ms 7 ms 15 ms 5 ms 8 ms RBR 111 A / RBR 111 AI high level net weight 0.02 kg (0.044 lb) product dimension 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in) packaging dimension 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/56 Interface relays R600 range Technical data Technical data RB... 111AR high level RB... 101AR high level Input circuit Rated control supply voltage Us 24 V AC/DC Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.24 W 10 mA 4.5 V green LED V: control supply voltage applied Output circuit Kind of output 5 11-12 13-14 relay, 1 n/o contact Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC Minimum switching voltage 12 V Maximum switching voltage 250 V AC Minimum switching current 10 mA Rated operational current AC12 (resistive) 230 V 6 A (IEC/EN 60947-5-1) AC15 (inductive) 230 V 1.5 A AC15 (inductive) 120 V 3 A DC12 (resistive) 24 V 6 A DC13 (inductive) 24 V 1 A DC13 (inductive) 120 V 0.2 A DC13 (inductive) 230 V 0.1 A AC rating Utilization category (pilot duty) B300 (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) R300 (UL 508; NEMA ICS-5) Minimum switching power 0.6 W / 0.6 VA Mechanical lifetime 1 x 107 switching cycles Electrical lifetime at AC15 1 x 10 5 switching cycles Response time 5 ms Release time 8 ms Dimensions and weight Weight Dimension RB 111AR / RB 101AR high level net weight 0.03 kg (0.066 lb) product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) packaging dimension 5/57 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 relay, 1 n/c contact - RBR 111A / RBR 111AR high level 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in) Interface relays R600 range Technical data Technical data RB... 121 / RB... 121A high level Input circuit Rated control supply voltage Us 5 V DC Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 12 V DC DC -15 %, +20 % AC 0.2 W 0.2 W 40 mA 16 mA 1.2 V 2.2 V green LED V: control supply voltage 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC -15 %, +10 % -/+ 10 % 50/60 Hz 0.24 W 10 mA 4.5 V applied 0.33 W 7 mA 8V 0.54 W 9 mA 8V 0.46 W 4 mA 17 V 0.8 W 3.5 mA 27 V Output circuit Kind of output 11-12/14 Rated operational voltage Ue (IEC/EN 60947-1) Minimum switching voltage Maximum switching voltage Minimum switching current Rated operational current AC12 (resistive) 230 V (IEC/EN 60947-5-1) AC15 (inductive) 230 V AC15 (inductive) 120 V DC12 (resistive) 24 V DC13 (inductive) 24 V DC13 (inductive) 120 V DC13 (inductive) 230 V AC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC15 Response time Release time Dimensions and weight Weight Dimension relay, 1 c/o (SPDT) contact 250 V AC 12 V 250 V AC 10 mA 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 5 R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 5 ms 8 ms 5 ms RB 121 / RB 121A high level net weight 0.02 kg (0.044 lb) product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) packaging dimension 5 ms 5 ms 6 ms 15 ms 7 ms 16 ms RBR 122 / RBR 122A high level 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in) 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/58 Interface relays R600 range Technical data Technical data RB... 121 / RB... 121A low level Input circuit Rated control supply voltage Us 5 V DC Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 12 V DC DC -15 %, +20 % AC 0.2 W 0.2 W 40 mA 16 mA 1.2 V 2.2 V green LED V: control supply voltage 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 V AC/DC 230 V AC/DC -15 %, +10 % -/+ 10 % 50/60 Hz 0.24 W 10 mA 4.5 V applied 0.33 W 7 mA 8V 0.54 W 9 mA 8V 0.46 W 4 mA 17 V 0.8 W 3.5 mA 27 V 5 ms 5 ms 6 ms 15 ms 7 ms 16 ms Output circuit 5 Kind of output 11-12/14 Rated operational voltage Ue (IEC/EN 60947-1) Minimum switching voltage Maximum switching voltage Minimum switching current Rated operational current AC12 (resistive) 230 V (IEC/EN 60947-5-1) AC15 (inductive) 230 V AC15 (inductive) 120 V DC12 (resistive) 24 V DC13 (inductive) 24 V DC13 (inductive) 120 V DC13 (inductive) 230 V AC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC15 Response time Release time Dimensions and weight Weight Dimension relay, 1 c/o (SPDT) contact 250 V AC 5V 250 V AC 1 mA 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 R300 0.05 W / 0.05 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 5 ms 5 ms 8 ms 5 ms RB 121 / RB 121A low level net weight 0.02 kg (0.044 lb) product dimension 6 x 70 x 75 mm (0.236 x 2.76 x 2.95 in) packaging dimension 5/59 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 RBR 122 / RBR 122A low level 6 x 75 x 75 mm (0.236 x 2.95 x 2.95 in) Interface relays R600 range Technical data Technical data RB... 121AR / RB... 121AI low level RB... 121AI low level Input circuit Rated control supply voltage Us 115 V AC/DC Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out voltage Indication of operational states 230 V AC/DC 24 V AC/DC DC -20%, +15% -10%, +15% AC -/+ 10 % 50/60 Hz 2W 2.8 W 18 mA 12 mA 17 V 27 V green LED V: control supply voltage applied 24 V AC/DC -20%, +15% 0.24 W 10 mA 4.5 V 0.24 W 10 mA Output circuit Kind of output 11-12/14 Rated operational voltage Ue (IEC/EN 60947-1) Minimum switching voltage Maximum switching voltage Minimum switching current Rated operational current AC12 (resistive) 230 V (IEC/EN 60947-5-1) AC15 (inductive) 230 V AC15 (inductive) 120 V DC12 (resistive) 24 V DC13 (inductive) 24 V DC13 (inductive) 120 V DC13 (inductive) 230 V AC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) DC rating Utilization category (pilot duty) (UL 508; NEMA ICS-5) Minimum switching power Mechanical lifetime Electrical lifetime at AC15 Response time Release time Dimensions and weight Weight Dimension relay, 1 c/o (SPDT) contact 250 V AC 12 V 250 V AC 10 mA 6A 1.5 A 3A 6A 1A 0.2 A 0.1 A B300 5V 1 mA 5 R300 0.6 W / 0.6 VA 1 x 107 switching cycles 1 x 10 5 switching cycles 6 ms 15 ms 0.05 W / 0.05 VA 7 ms 16 ms 5 ms 8 ms RB 121AR/RB 121AI low/high level net weight 0.03 kg (0.066 lb) product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) packaging dimension 5 ms 8 ms RB 121AR/RBR 121AI low/high level 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in) Technical data RB... 122A low level Input circuit Rated control supply voltage Us 24 V AC/DC Rated control supply voltage Us tolerance Rated frequency Typical power consumption Typical current Drop-out Indication of operational states 48 V AC/DC DC -15 %, +20 % AC -/+ 10 % 50/60 Hz 0.48 W 0.62 W 20 mA 13 mA 5.4 V 8.8 V green LED V: control supply voltage applied 60 V AC/DC 115 V AC/DC 230 V AC/DC -15 %, +10 % 0.96 W 16 mA 8.8 V V 0.58 W 5 mA 20 V 1.15 W 5 mA 10 V 6 ms 15 ms 6 ms 15 ms Output circuit Kind of output 11-12/14 relay, 1st c/o (SPDT) contact 21-22/24 relay, 2nd c/o (SPDT) contact Rated operational voltage Ue (IEC/EN 60947-1) 250 V AC Minimum switching voltage 5V Maximum switching voltage 250 V DC - 250 V AC Minimum switching current 1 mA AC12 (resistive) 230 V 8 A Rated operational current (IEC/EN 60947-5-1) Minimum switching power 5 mW / 5 mVA Mechanical lifetime 2 x 107 switching cycles Electrical lifetime at AC15 1 x 10 5 switching cycles Response time 6 ms 10 ms Release time 10 ms 14 ms Dimensions and weight Weight Dimension RB 122A low level net weight 0.03 kg (0.066 lb) product dimension 12 x 70 x 75 mm (0.472 x 2.76 x 2.95 in) packaging dimension 5A 10 ms 14 ms RBR 122A low level 12 x 75 x 75 mm (0.472 x 2.95 x 2.95 in) 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/60 Interface relays R600 range General technical data Technical data RB RBR Screw terminal Spring-type terminal General data Material of housing Degree of protection UL 94 V0 housing / IP20 NEMA1 terminals Electrical connection Wire size Stripping length Tightening torque fine-stranded 0.22-2.5 mm² (24-14 AWG) rigid 0.2-4 mm² (24-12 AWG) 9 mm / 0.354 in 0.4-0.6 Nm (3.5-5.3 lb.in) 0.2-2.5 mm² (24-14 AWG) Environmental data Ambient temperature ranges storage -40...+80 °C operation -20...+70 °C Isolation data 5 Rated insulation voltage Ui (IEC/EN 60950-1, EN 50178) Rated impulse withstand voltage input / output Uimp (EN 50178) shock coil / output output / output 4000 V RMS 4000 V RMS (RB122A: 3800 V RMS, RB111AR: 3500 V RMS) 4000 V RMS 1000 V RMS 5/61 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Interface relays R600 range Dimensional drawings, Load limit curves All interface relays of R600 range center of rail center of rail Spring clamp module Screw clamp module 5 Load limit curves RB 111 A, RB 111 AI, RB 111 AR, RB 101 AR, RB 121 AR, RB 121 AI, RB 121 AI (gold plated), RB 121 AI RB 121 (gold plated), RB 121 A (gold plated), RB 121, RB 121 A Limited load in CC Load limit curve RB ... 122A (gold plated) Voltage [V] Voltage (Vcc) Max. DC load breaking capacity resistive load Current (Acc) 24 V 110/120 V 220/230 V DC12 AC12 DC13 AC15 6A 0,3 A 0.2 A 6A 6A 6A 1 0.2 A 0.1 A 3A 3A 3A Current [A] 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/62 Optocouplers R600 range Product group picture 5 5/63 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Optocouplers R600 range Table of contents Optocouplers R600 range Product group picture 5/63 Table of contents 5/64 Selection 5/65 Ordering details 5/67 Connection diagrams 5/68 Technical data 5/69 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/64 Order number 1SNA 645 047 R0000 1SNA 645 547 R0200 1SNA 645 021 R2600 1SNA 645 521 R2000 1SNA 645 049 R1200 1SNA 645 549 R1400 1SNA 645 022 R2700 1SNA 645 550 R1100 1SNA 645 051 R0400 1SNA 645 025 R2200 1SNA 645 024 R2100 1SNA 645 551 R0600 1SNA 645 525 R2400 1SNA 645 524 R2300 1SNA 645 053 R0600 1SNA 645 553 R0000 1SNA 645 054 R0700 1SNA 645 058 R1300 1SNA 645 554 R0100 1SNA 645 558 R1500 1SNA 645 026 R2300 1SNA 645 059 R1400 1SNA 645 526 R2500 1SNA 645 559 R1600 1SNA 645 027 R2400 1SNA 645 029 R0600 1SNA 645 527 R2600 1SNA 645 529 R0000 OBRIC 0100 5-12VDC OBIC 0100 24VDC OBRIC 0100 24VDC OBIC 0100 48-60VAC/DC OBRIC 0100 48-60VAC/DC OBIC 0100 115-230VAC/DC OBRIC 0100 115-230VAC/DC 1SNA 645 522 R2100 1SNA 645 050 R1700 OBIC 0100 5-12VDC OBOC 1000-5-12VDC OBROC 1000-5-12VDC OBOC 1000-24VDC OBOC 1500-24VAC/DC OBOC 5000-24VDC OBROC 1000-24VDC OBROC 1500-24VAC/DC OBROC 5000-24VDC OBOC 1000-48-60VAC/DC OBROC 1000-48-60VAC/DC OBOC 1000-115VAC/DC OBOC 5000-115VAC/DC OBROC 1000-115VAC/DC OBROC 5000-115VAC/DC OBOC 1000-230VAC/DC OBOC 5000-230VAC/DC OBROC 1000-230VAC/DC OBROC 5000-230VAC/DC OBOA 1000-24VDC OBOA 2000-24VDC OBROA 1000-24VDC OBROA 2000-24VDC 5 Type Optocouplers R600 range Selection Input voltage 5 - 12 V DC n n n n 24 V DC n n n n n n n n n n n n 48 - 60 V DC n n n n 115 - 230 V DC n n 115 V DC n n n n 230 V DC n n n n n n 24 V AC n n 48 - 60 V AC n n n n 115-230 V AC n n 115 V AC n n n n 230 V AC n n n n Output rating 100 mA n n n n n n n n 2A n n n n n n n n n n n n n n 5A n n n n n n 1A Output voltage n n 58 V DC n n n n n n n n n n n n n n n n n n n n n n n n n n 400 V AC Terminal type n n n n Screw n n n n n n n n n n n n n n n Spring n n n n n n n n n n n n n n n 5/65 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 n n n n 1SNA 645 528 R0700 1SNA 645 562 R0100 OBROA 1000-115VAC/DC n 1SNA 645 028 R0500 1SNA 645 062 R0700 OBOA 1000-115VAC/DC n OBROA 1000-230VAC/DC 1SNA 645 561 R0000 OBROA 1000-48-60VAC/DC OBOA 1000-230VAC/DC 1SNA 645 061 R0600 OBOA 1000-48-60VAC/DC Optocouplers R600 range Selection n n n n n n n n n n n n n n n n n n n n n n n 5 n 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/66 Optocouplers R600 range Ordering details R600 Optocoupler Optocoupler module 100 mA/DC Type Order code OBIC 0100-5-12VDC 1SNA645047R0000 OBIC 0100-24VDC 1SNA645021R2600 Price OBIC 0100-48-60VAC/DC 1SNA645049R1200 Pkg Weight qty (1 pce) kg (lb) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.02 (0.44) 10 0.03 (0.066) 5 0.03 (0.066) 10 0.03 (0.066) 5 0.03 (0.066) 2CDC 291 001 F0013 OBIC 0100-115-230VAC/DC 1SNA645022R2700 Optocoupler module 100 mA/DC 5 Optocoupler module 2 A/DC Optocoupler module 5 A/DC Optocoupler module 5 A/DC Optocoupler module 1 A/AC 6 mm spacing Optocoupler module 2 A/AC 12 mm spacing Optocoupler module 1 A/AC 6 mm spacing Optocoupler module 2 A/AC 12 mm spacing Accessories SC612 FC2 OBOC 1000-5-12VDC 1SNA645050R1700 OBOC 1000-24VDC 1SNA645051R0400 OBOC 1500-24VAC/DC 1SNA645025R2200 OBOC 1000-48-60VAC/DC 1SNA645053R0600 OBOC 1000-115VAC/DC 1SNA645054R0700 OBOC 1000-230VAC/DC 1SNA645026R2300 OBROC 1000-5-12VDC 1SNA645550R1100 OBROC 1000-24VDC 1SNA645551R0600 OBROC 1500-24VAC/DC 1SNA645525R2400 OBROC 1000-48-60VAC/DC 1SNA645553R0000 OBROC 1000-115VAC/DC 1SNA645554R0100 OBROC 1000-230VAC/DC OBOC 5000-24VDC OBOC 5000-115VAC/DC 1SNA645526R2500 1SNA645024R2100 1SNA645058R1300 OBOC 5000-230VAC/DC 1SNA645059R1400 OBROC 5000-24VDC 1SNA645524R2300 OBROC 5000-115VAC/DC 1SNA645558R1500 OBROC 5000-230VAC/DC 1SNA645559R1600 OBOA 1000-24VDC 1SNA645027R2400 OBOA 1000-48-60VAC/DC 1SNA645061R0600 OBOA 1000-115VAC/DC 1SNA645062R0700 OBOA 1000-230VAC/DC 1SNA645028R0500 OBOA 2000-24VDC 1SNA645029R0600 OBROA 1000-24VDC 1SNA645527R2600 OBROA 1000-48-60VAC/DC 1SNA645561R0000 OBROA 1000-115VAC/DC 1SNA645562R0100 OBROA 1000-230VAC/DC 1SNA645528R0700 OBROA 2000-24VDC 1SNA645529R0000 Order code BADH V0 1SNA116900R2700 50 BADL V0 1SNA399903R0200 50 BAM2 V0 1SNA399967R0100 50 Seperator end section SC 612 1SNA290474R0200 10 Divisible shunt 10 poles BJ 612-10 1SNA290488R0100 10 Divisible shunt 20 poles BJ 612-20 1SNA206754R0000 10 Screw clamp distribution block sp. 12 mm D4/12-3-3 1SNA645031R2000 5 Spring clamp distribution block sp. 12 mm D4/12-3R-3R 1SNA645531R2200 5 Test plug DIA. 2 mm FC2 1SNA645531R2200 10 Marking method RC65 / RC610 see marking End section D 4/12-3... 1SNA645521R2000 OBRIC 0100-48-60VAC/DC 1SNA645549R1400 Type BADH BJ... 1SNA645547R0200 OBRIC 0100-24VDC OBRIC 0100-115-230VAC/DC 1SNA645522R2100 Optocoupler module 2 A/DC BADL OBRIC 0100-5-12VDC 5/67 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Price Pkg Weight qty (1 pce) kg (lb) Optocouplers R600 range Connection diagrams OB...IC 0100 - 5-12 V DC 115-230 V AC/DC OB...IC 0100 24 V DC 24-48-60 V AC/DC OB...OC 1000 - 5-12 V DC 5 OB...OC 1500 - 24 V AC/DC OB...OC 1000 24 V DC 48-60-115-230 V AC/DC OB...OC 5000 24 V DC 24-48-60-115-230 V AC/DC OB...OA 1000 24 V DC 48-60-115-230 V AC/DC OB...OA 2000 - 24 V DC 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/68 Optocouplers R600 range Technical data Technical data Optocoupler : 5 to 58 V DC output / 100 mA - 6 mm 0.236“ spacing OB...IC 0100 Relay characteristics coil Input voltage: +20%, -15% on DC ; 10%, -10% on AC 5 V DC - 12 V DC 24 V DC 48 V AC/DC Frequency 5 Input current AC/DC 5 mA Pull-in voltage at Is=100% 4V Switching time C / O 10 µs / 500 µs Operating frequency 9 mA 115 V AC/DC 230 V AC/DC 5 mA 7 mA / 16 mA 11.5 mA / 25 mA 1000 Hz 4 mA 4 mA 15 V 25 V 60 V AC / 70 V DC 5 ms / 20 ms 5 ms / 15 ms Permissible leakage current 20 Hz Output 0.9 mA Output voltage 4.5 to 58 V DC Output current min. 1 mA Output current max. 100 mA Output leakage current at Umax. Redidual voltage at I max and U rated 60 V AC/DC 50 / 60 Hz 1 mA 0.9 mA 1.6 mA < 50 µA typical 1 V max 1.3 V Frequency on inductive load Isolation Input / Output Temperature input / Output 2500 V RMS storage -40...+80 °C operating -20...+70 °C 1) Other characteristics Body material Wire size Screw clamp Solid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending for 12 V DC) , Reference standards 1) Spring clamp grey UL 94 V0 (pending), , LRS , CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased. Dimensional drawings center of rail Screw clamp module center of rail Spring clamp module 5/69 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Optocouplers R600 range Technical data Technical data Optocoupler : 5 to 58 V DC output / 2 A - 6 mm 0.236“ spacing OB..OC OB...OC 0100 OB...OC 1000 1500 Relay characteristics coil Input voltage: +20%, -15% on DC ; 10%, -10% on AC 5 V DC - 12 V DC 24 V DC Frequency V AC/ 24 V AC/DC 48 V AC/DC 60 V AC/DC 115 DC 230 V AC/ DC 50 / 60 Hz Input current 5 mA Pull-in voltage at Is=100% 9 mA 4 mA 6.3 mA 4 mA 4V 15 V 15 V 27 V Switching time C / O 15 µs / 250 µs 30 µs / 400 µs 1 ms / 7 ms 5 ms / 20 ms Operating frequency 2000 Hz 1000 Hz 60 Hz 20 Hz Permissible leakage current 1 mA 0.8 mA 0.9 mA 1 mA 5.1 mA 4.2 mA 4 mA 50 V 80 V 500 µs / 10 ms 1 ms / 15 ms 5 0.3 mA Output Output voltage 4.5 to 58 V DC Output current min. 1 mA Output current max. 2A Output leakage current at Umax. Redidual voltage at I max and U rated < 50 µA typical 0.1 V max 0.5 V Frequency on inductive load Isolation Input / Output Temperature input / Output 2500 V RMS storage -40...+80 °C operating -20...+70 °C 1) Other characteristics Body material Wire size Screw clamp Solid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending for 12 V DC) , Reference standards 1) Spring clamp grey UL 94 V0 (pending), , LRS , CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased. Dimensional drawings center of rail Screw clamp module center of rail Spring clamp module 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/70 Optocouplers R600 range Technical data Technical data Optocoupler : 5 to 58 V DC output / 5 A - 6 mm 0.236“ spacing OB... OC 5000 Input Input voltage 24 V DC Frequency 5 115 V AC/DC 230 V AC/DC 50 / 60 Hz 50 / 60 Hz Input current 5.4 mA 4.2 mA 4 mA Pull-in voltage at Is=100% 12 V 50 V 80 V Switching time C / O 30 µs / 400 µs 500 µs / 10 ms 1ms / 15 ms Operating frequency 1000 Hz 50 Hz 35 Hz Permissible leakage current 0.8 mA 0.3 mA 0.3 mA Output Output voltage 4.5- 58 V DC Output current min. 25 mA Output current max. 5A Output leakage current at Umax. Redidual voltage at I max and U rated < 0.50 mA typical 1 V max 1.6 V Frequency on inductive load Isolation Input / Output See Note 1 input / Output 2500 V RMS Temperature Ambient temperature storage -40...+80 °C operating See derating curve Other characteristics Body material Wire size grey UL 94 V0 Solid wire 0.2 - 4 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 10 mm (0.394 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending), Reference standards CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Dimensional drawings center of rail Screw clamp module center of rail Spring clamp module 5/71 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 Optocouplers R600 range Technical data Technical data Optocoupler : 24 to 400 V AC output / 2 A max. - 6 mm or 12 mm spacing OB...OA OB...OA 1000 2000 Relay characteristics coil Input voltage: +20%, -15% on DC ; 10%, -10% on AC 24 V DC 48 V AC/DC Frequency 60 V AC/DC 115 V AC/DC 230 V AC/DC 24 V DC 3.6 mA 50/60 Hz Input current 3.6 mA 4.3 mA 5.5 mA 4.15 mA 4.6 mA Pull-in voltage at Is=100% 14 V 15 V 18 V 60 V 135 V 14 V Switching time C / O 150 µs / 1 ms 3 ms / 30 ms 2.2 ms / 18 ms 2.5 ms / 25 ms 150 µs / 1 ms Operating frequency 500 Hz 20 Hz 25 Hz 20 Hz 500 Hz Permissible leakage current 1 mA 5 Output Output voltage 24-400 V AC Frequency 50/60 Hz Output current min. 25 mA Output current max. 1A Output leakage current at Umax. < 0.50 mA Redidual voltage at I max and U rated 2A typical 1 V max 1.6 V Frequency on inductive load Isolation Input / Output Temperature input / Output 2500 V RMS storage -40...+80 °C operating -20...+70 °C 1) Other characteristics Body material Wire size Screw clamp Solid wire 0.2 - 4 mm² (24-12 AWG) 0.2-2.5 mm² (24-12 AWG) Stranded wire 0.22 - 2.5 mm² (24-12 AWG) Rated wire size 2.5 mm² (12 AWG) Wire stripping length 9 mm (0.354 in) Recommended screwdriver 3.5 mm (0.137 in) Protection IP20 NEMA1 Recommended torque 0.4-0.6 Nm (3.5-5.3 lb.in) Approvals (pending for 12 V DC) , Reference standards 1) Spring clamp grey UL 94 V0 (pending), , LRS , CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IEC 1000-4-2, 3, 4, 5, 6. Over 55°C, blocks have to be mounted on horizontal rail with 10 mm spacing between each block. For vertical rail mounting use temperature is 15°C less decreased. Dimensional drawings center of rail Screw clamp module center of rail Spring clamp module 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/72 Terminal blocks component holder D 2,5/5-MP Spacing 5,08 mm (.200") 1 DIN 3 D 2,5/5-MP... Spacing 5,08 mm (.200") Base for pluggable plug R500 Series D 2,5/5-MP1 Spacing 5,08 mm (.200") 1 4 2 4 2 2 5 5 3 5 3 3 6 End stop th. 9 mm BADL V0 1SNA 399 903 R0200 th. 9,1 mm BAM V2 End stop 1SNA 103 002 R2600 th. 9,1 mm BAM V0 V0 End stop 1SNA 199 306 R0300 35 x 7,5 x 1 PR3.Z2 Rail 1SNA 174 300 R1700 35 x 15 x 2,3 PR4 Rail 1SNA 168 500 R1200 35 x 15 x 1,5 PR5 Rail 1SNA 168 700 R2200 1 4 6 6 center of rail center of rail Relay/opto. base without output LED center of rail Relay/opto. base without input LED Relay/opto. base with output LED Observations Terminal blocks are delivered without plugs. Type Grey V0 Max. working temperature version without LED : 100°C version with LED : 85°C Contact resistance : < 5 mΩ Part numbers Type Grey V0 Order plugs separately D 2,5/5-MP Part numbers D 2,5/5-MP1 1SNA607224R0100 Type Grey V0 Order plugs separately 1SNA607223R0000 Part numbers Order plugs separately 2,5/5-MP-24VDC D 1SNA607222R0700 2,5/5-MP-24VAC/DC D 1SNA607260R2100 1SNA607261R1600 D 2,5/5-MP-48VAC/DC 2,5/5-MP-110VAC D 5 1SNA607266R1300 1SNA607267R1400 D 2,5/5-MP-230VAC Characteristics Wire size Voltage IEC UL/CSA Compression clamp Rated Pulse Pollution degree Rated Rated / Gauge Current Wire size Wire stripping length Recommended screwdriver Recommended torque Protection pending Solid wire 0,2-4 mm² 24-12 AWG Stranded wire 0,22-2,5 mm² 24-12 AWG 320 V 300 V 4 kV 3 6 A 6A 2,5 mm² 12 AWG 10 mm / .394" 3,5 mm / .137" 0,4-0,6 Nm / 3,5-5,3 lb.in IP 20 / NEMA1 Accessories 1 Test device 2 Test plug 1 3 Relay plug 1 SPDT 10 mA/6 A 1 SPDT 1 mA/6 A 4 Input optocoupler plug 5 V DC 24 V DC 24 V DC 2 48 V DC 125 V DC 24 V AC 48 V AC 115 V AC 230 V AC 5 Output optocoupler 24 V DC/100 mA plug 24 V DC/100 mA 3, 4, 5, 6, 24 V DC/2 A 7, 8, 9 24 V DC/2 A 24 V DC/1 A 24 V DC/1 A 24 V DC/1 A 5 Output optocoupler 5 V DC/100 mA plug 5 V DC/100 mA 48 V DC/100 mA 48 V DC/100 mA 10 5 V DC/2 A 5 V DC/2 A 5 V DC/1 A 5 V DC/1 A 7 Fuse plug 125 V/125 mA 125 V/500 mA 125 V/2 A 125 V/5 A 250 V/125 mA 250 V/2 A 250 V/5 A 125 V/125 mA 250 V/125 mA 125 V/2 A 8 Strap plug 9 Converter plug 0-20 mA/0-10 V 4-20 mA/2-10 V 0-20 mA/0-5 V 4-20 mA/1-5 V 10 Comb type jumper bar 10 poles R R See section on marking Type blue DCB (1) DIA. 2 FC2 beige BNMS R24V-1 beige BNMS R24V-2 Type 1SNA031807R1400 1SNA031810R1200 1SNA031813R0100 1SNA031815R0300 1SNA031817R0500 1SNA031819R1700 1SNA031839R1300 1SNA031806R1300 1SNA031809R2600 1SNA031808R2500 1SNA031811R0700 1SNA031812R0000 1SNA031814R0200 1SNA031816R0400 1SNA031818R1600 1SNA031821R0100 1SNA031838R1200 1SNA031822R0200 1SNA031823R0300 1SNA031824R0400 1SNA031825R0500 1SNA031826R0600 1SNA031827R0700 1SNA031828R1000 1SNA031849R2500 1SNA031829R1100 1SNA031830R1600 1SNA031832R0400 1SNA031832R0400 1SNA031833R0500 1SNA031833R0500 1SNA205523R2200 RC 55 BNMS F125mA-1 grey BNMS F500mA-1 grey BNMS F2A-1 grey BNMS F5A-1 grey BNMS F125mA-2 grey BNMS F2A-2 grey BNMS F5A-2 grey pending 0,2-4 mm² 24-12 AWG 0,22-2,5 mm² 24-12 AWG 320 V 300 V 4 kV 3 6 A 6A 2,5 mm² 12 AWG 10 mm / .394" 3,5 mm / .137" 0,4-0,6 Nm / 3,5-5,3 lb.in IP 20 / NEMA1 1SNA031821R0100 1SNA031838R1200 1SNA031822R0200 1SNA031823R0300 1SNA031824R0400 1SNA031825R0500 1SNA031826R0600 Type DCB (1) blue FC2 DIA. 2 BNMS R24V-1 beige BNMS R24V-2 beige Part numbers 1SNA105028R2100 1SNA007865R2600 1SNA031820R1400 1SNA031847R1300 BNMS N24V-3 red BNMS P24V-3 red BNMS N24V-1 red BNMS P24V-1 red BNMS N24V-2 red BNMS P24V-2 red BNMS A24V-4 black 1SNA031807R1400 1SNA031810R1200 1SNA031813R0100 1SNA031815R0300 1SNA031817R0500 1SNA031819R1700 1SNA031839R1300 BNMS F125mA-1 grey BNMS F500mA-1 grey BNMS F2A-1 grey BNMS F5A-1 grey BNMS F125mA-2 grey BNMS F2A-2 grey BNMS F5A-2 grey BNMS F125mA-3 grey BNMS F125mA-4 grey 1SNA031821R0100 1SNA031838R1200 1SNA031822R0200 1SNA031823R0300 1SNA031824R0400 1SNA031825R0500 1SNA031826R0600 1SNA031827R0700 1SNA031828R1000 BNMS F2A-7 grey 1SNA031849R2500 1SNA031829R1100 BNMS ST2 grey 1SNA031830R1600 BNMS ST1 grey PCMS RC 55 V0 (2) 1SNA205523R2200 BNMS ST1 grey 1SNA031829R1100 PCMS V0 (2) (1) Solely on the top stage. (2) Comb type jumper bar from 2 to 22 poles, see accessories. 5/73 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 IEC UL/CSA Part numbers DCB (1) blue FC2 DIA. 2 1SNA105028R2100 1SNA007865R2600 BNMS T5V-1 white 1SNA031831R0300 BNMS T24V-1 white 1SNA031848R2400 BNMS T24V-2 white 1SNA031800R2100 BNMS T48V-1 white 1SNA031801R1600 BNMS T125V-1 white 1SNA031845R1100 BNMS T24V-1 yellow 1SNA031802R1700 BNMS T48V-1 yellow 1SNA031803R1000 BNMS T115V-1 yellow 1SNA031804R1100 BNMS T230V-1 yellow 1SNA031805R1200 red BNMS N24V-3 red BNMS P24V-3 red BNMS N24V-1 red BNMS P24V-1 red BNMS N24V-2 red BNMS P24V-2 black BNMS A24V-4 red BNMS N5V-3 red BNMS P5V-3 red BNMS N48V-3 red BNMS P48V-3 red BNMS N5V-1 red BNMS P5V-1 red BNMS N5V-2 red BNMS P5V-2 grey BNMS F125mA-1 grey BNMS F500mA-1 grey BNMS F2A-1 grey BNMS F5A-1 grey BNMS F125mA-2 grey BNMS F2A-2 grey BNMS F5A-2 grey BNMS F125mA-3 grey BNMS F125mA-4 grey BNMS F2A-7 grey BNMS ST1 grey BNMS ST2 grey BNMS CAI/U-500 grey BNMS CAI/U-500 grey BNMS CAI/U-250 BNMS CAI/U-250 PCMS V0 (2) pending 0,2-4 mm² 24-12 AWG 0,22-2,5 mm² 24-12 AWG 320 V 300 V 4 kV 3 6 A 6A 2,5 mm² 12 AWG 10 mm / .394" 3,5 mm / .137" 0,4-0,6 Nm / 3,5-5,3 lb.in IP 20 / NEMA1 Part numbers 1SNA105028R2100 1SNA007865R2600 1SNA031820R1400 1SNA031847R1300 IEC UL/CSA RC 55 1SNA 205523R2200 DC plugs AC plugs 2 2 3 4 1 Derating curve 3 4 Switching time RL curve 1 for 24 V DC plugs only 1 Switching time (µs) 2CDC 292 013 F0013 Input optocoupler plugs Derating curve Load resistance RL (kW) 5 V DC Part number 24 V DC Type P/N 48 V DC Type P/N Type P/N 5 125 V DC Type P/N BNMS T48V-1 BNMS T125V-1 BNMS T5V-1 BNMS T24V-1 1SNA031831R0300 1SNA031801R1600 1SNA031845R1100 1SNA031800R2100 BNMS T24V-2 1SNA031848R2400 Characteristics INPUT Voltage Max. current Typical triggering threshol at Is = 100% Switching time C/O Leakage current OUTPUT Max. voltage. / Max. current Residual voltage max. I and rated U standard max. Compatibility Input / Ouput isolation TEMPERATURE Storage Operating 4,5 V to 5,5 V DC 6 mA 3,5 V 20 µs / 1,3 ms 58 V / 30 mA 2,3 V DC 2,7 V DC 2,5 kV - 30°C to + 80°C - 20°C to + 55°C BNMS T24V-1 BNMS T24V-2 19,2 V to 27,6 V DC 5 mA 12 V DC 20 µs / 1,3 ms 10 µs / see curve 1 1 mA 58 V / 30 mA 58 V / 5 mA 2,3 V DC 0,3 V DC 2,7 V DC 0,5 V DC TTL 2,5 kV 48 V AC 24 V AC Part number - 30°C to + 80°C -20°C to + 55°C 58 V / 30 mA 2,3 V DC 2,7 V DC 2,5 kV - 30°C to + 80°C - 20°C to + 55°C 115 V AC Type P/N Type P/N 38,4 V to 55,2 V DC 4,1 mA 21 V DC 20 µs / 1,3 ms 0,8 mA 93,5 V to 140 V DC 3 mA 50 V DC 20 µs / 1,3 ms 58 V / 30 mA 2,3 V DC 2,7 V DC 2,5 kV - 30°C to + 80°C - 20°C to + 55°C 230 V AC Type P/N Type P/N BNMS T24V-1 BNMS T48V-1 BNMS T115V-1 BNMS T230V-1 1SNA031802R1700 1SNA031803R1000 1SNA031804R1100 1SNA031805R1200 Charateristics INPUT Voltage Max. current Typical triggering threshold at Is = 100% Switching time C/O Leakage current OUPUT Max. voltage / Max. current Residual voltage max. I and rated U standard max. Input / Ouput isolation TEMPERATURE Storage Operating 20,4 V to 26,4 V AC 8,5 mA 13 V AC 6 ms / 10 ms 1 mA 58 V / 30 mA 2,3 V DC 2,7 V DC - 30°C to + 80°C - 20°C to + 55°C 2,5 kV 40,8 V to 52,8 V AC 4,5 mA 22 V AC 6 ms / 10 ms 1 mA 58 V / 30 mA 2,3 V 2,7 V 2,5 kV - 30°C to + 80°C - 20°C to + 55°C 98 V to 126,5 V AC 8 mA 50 V AC 6 ms / 10 ms 2 mA 58 V / 30 mA 2,3 V 2,7 V 2,5 kV - 30°C to + 80°C - 20°C to + 55°C 195,5 V to 253 V AC 7 mA 95 V AC 6 ms / 10 ms 2 mA 58 V / 30 mA 2,3 V 2,7 V 2,5 kV - 30°C to + 80°C - 20°C to + 55°C 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/74 100 mA output optocoupler Transistor output optocoupler plugs 2CDC 292 013 F0013 2 3 4 1 2 3 N5V-3 4 100 mA output optocoupler 24 V DC 2 1 3 4 1 2 3 N24V-3 P5V-3 Derating curve 4 48 V DC 1 2 P24V-3 3 100 2 3 0 (°C) 57 60 0 57 60 (°C) Type P/N Type P/N BNMS N5V-3 BNMS P5V-3 BNMS N24V-3 BNMS P24V-3 BNMS N48V-3 BNMS P48V-3 1SNA031809R2600 1SNA031807R1400 1SNA031810R1200 1SNA031808R2500 1SNA031811R0700 Characteristics 4,5 V to 5,5 V DC 8,5 mA 2,9 V DC 20 µs / 1,3 ms 1 mA OUTPUT Max. voltage / Max. current Residual voltage max. I and rated U standard U max. Frequency on inductive load Input / Output isolation 58 V / 100 mA 1 V DC 1,3 V DC See Note 1 2,5 kV TEMPERATURE Storage Operating - 30°C to + 80°C - 20°C to + 60°C 20,4 V to 28,8 V DC 4,8 mA 16 V DC 20 µs / 1,3 ms 1 mA 1 V DC 1,3 V DC See Note 1 2,5 kV - 30°C to + 80°C - 20°C to + 60°C 58 V / 100 mA 1 A output optocoupler MOS output optocoupler plugs 40,8 V to 57,6 V DC 3,9 mA 26 V DC 20 µs / 1,3 ms 1 mA 58 V / 100 mA 1 V DC 1,3 V DC See Note 1 2,5 kV - 30°C to + 80°C - 20°C to + 60°C 1 A output optocoupler 5 V DC 24 V DC Note 1 : Fmax = (1-0,007 x Us) / (L x Is²) or Fmax = (1-0,007 x Us) / (P x L ) R 2CDC 292 013 F0013 5 INPUT Voltage Max. current Typical triggering threshold at Is = 100 % Switching time C/O Leakage current Part numbers 2 3 4 1 2 3 N5V-2 4 1 2 P5V-2 3 4 1 2 3 1 Derating curve Type P/N Type P/N BNMS N5V-2 BNMS P5V-2 BNMS N24V-2 BNMS P24V-2 1SNA031816R0400 1SNA031818R1600 4 P24V-2 N24V-2 Derating curve 1SNA031817R0500 1SNA031819R1700 Characteristics INPUT Voltage Max. current Typical triggering threshold at Is=100% Switching time C/O Leakage current 4,5 V to 5,5 V DC 12,5 mA 3,5 V DC 20 µs / 250 µs 1 mA 20,4 V to 28,8 V DC 6,7 mA 10 V DC 50 µs / 350 µs 1 mA OUTPUT Max. voltage / Max. current Residual voltage max. I and rated U standard U max. Frequency on inductive load Input / Output isolation 58 V / See graphs 58 V / See graphs 1 V DC 1,3 V DC See Note 1 2,5 kV 1 V DC 1,3 V DC See Note 1 2,5 kV TEMPERATURE Storage Operating - 30°C to + 80°C - 20°C to + 60°C - 30°C to + 80°C - 20°C to + 60°C 5/75 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 1 100 Type P/N 1SNA031806R1300 4 P48V-3 I (mA) 100 (°C) 1 Derating curve I (mA) 57 60 4 N48V-3 Derating curve I (mA) 0 Part numbers 100 mA output optocoupler 5 V DC Us Is L P R = Output voltage supply = Output current = Inductive load = Load power = Load resistance 2 A output optocoupler 2 A output optocoupler MOS output optocoupler plug 24 V DC 5 V DC Note 2 : Fmax = (1 - 0,012 x Us) / (L x Is²) or Fmax = (1 - 0,012 x Us) / (P x L ) R 2CDC 292 013 F0013 2 3 4 1 2 3 N5V-1 4 2 1 P5V-1 3 4 1 N24V-1 Derating curve Part numbers 2 3 4 1 P24V-1 Derating curve Type P/N Type P/N BNMS N5V-1 BNMS P5V-1 BNMS N24V-1 BNMS P24V-1 1SNA031812R0000 1SNA031814R0200 Us = Output voltage supply Is = Output current L = Inductive load P = Load power R = Load resistance 1SNA031813R0100 1SNA031815R0300 Characteristics INPUT Voltage Max. current Typical triggering threshold Switching time Leakage current C/O 4,5 V to 5,5 V DC 12,5 mA 3,5 V DC 20 µs / 250 µs 1 mA 20,4 V to 28,8 V DC 6,7 mA 10 V DC 50 µs / 350 µs 1 mA OUTPUT Max. voltage / Max. current Residual voltage max. I and rated U standard U max. Frequency on inductive load Input / Output isolation 30 V DC / See graphs 1 V DC 1,3 V DC See Note 2 2,5 kV 30 V / See graphs 1 V DC 1,3 V DC See Note 2 2,5 kV TEMPERATURE Storage Operating - 30°C to + 80°C - 20°C to + 60°C 5 - 30°C to + 80°C - 20°C to + 60°C 1 A output optocoupler Triac output optocoupler plug 2CDC 292 013 F0013 24 V DC 2 3 4 1 Derating curve Part numbers Type P/N BNMS A24V-4 1SNA031839R1300 Characteristics INPUT Voltage Max. current Typical triggering threshold Switching time Leakage current C/O 20,4 V to 28,8 V DC 3,8 mA 10 V DC 9,5 ms / 12 ms OUTPUT Max. voltage / Max. current Residual voltage max. I and rated U standard U max. Input / Output isolation 24 V to 253 V AC / See derating curve 1 V AC 1,3 V AC 2,5 kV TEMPERATURE Storage Operating - 30°C to + 80°C - 20°C to + 70°C 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/76 Relay plugs 1 SPDT relay 2CDC 292 013 F0013 Derating curve I(A) 6 2 5 4 2 1 0 1SNA031820R1400 BNMS R24V-2 1SNA031847R1300 BNMS R24V-1 Analogical plugs 2CDC 292 013 F0013 20 30 40 44 52 55 Θ(°C) Limited load in CC Voltage (Vcc) BNMS R24V-1 BNMS R24V-2 Current / Voltage Converter 2 3 4 Voltage (Vcc) COIL 20,4 V to 28,8 V DC Voltage 7 mA Current max. 1,2 V Trip voltage CONTACT 1 SPDT Type 12 V / 250 V 5 V / 250 V Voltage mini. / max. 10 mA / 6 A 1 mA / 6 A Switching current mini. / max. Switching current AC1 mini. / max. 0,6 VA/1500 VA (resistance) 0,05 VA/1500 VA (resistance) 0,6 W / 140 W 0,05 W / 140 W DC1 mini. / max. Number of operations on load 105 operations for AC15 Number of operations off load 10x106 operations 6 ms / 8 ms Operating speed C/O 1,5 ms Bounce 4 kV Isolation Coil / Contact 4 kV Resistance to shock waves Coil / Contact 1 kV Isolation Contact / Contact TEMPERATURE - 40°C to + 80°C Storage - 20°C to + 55°C Operating Part numbers 10 Type P/N Current (Acc) Current (Acc) 24 V 110/120 V 220/230 V DC12 6 A 0,3 A 0,2 A 1 2 3 4 Type P/N Type P/N 1SNA031832R0400 DC13 1 A 0,2 A 0,1 A AC15 3A 3A 3A 1 Plug with 500 Ω accuracy resistance for analogical signals. BNMS CA I/U-250 AC12 6 A 6 A 6 A Current / Voltage Converter Plug with 250 Ω accuracy resistance for analogical signals. BNMS CA I/U-500 1SNA031833R0500 Characteristics Resistance Power Accuracy Stability 250 Ω 0,35 W 0,1 % 25 ppm Fuse and strap plugs 500 Ω 0,35 W 0,1 % 25 ppm Output fuse plug 2CDC 292 013 F0013 5 3 R24V-1 Part numbers Characteristics 24 V DC 2 4 Input fuse plug 1 2 5 4 1 Strap plug 2 1 BNMS ST1 Part numbers Type P/N BNMS BNMS BNMS BNMS BNMS BNMS BNMS F125mA-1 F500mA-1 F2A-1 F5A-1 F125mA-2 F2A-2 F5A-2 125 V / 125 mA 125 V / 500 mA 125 V / 2 A 125 V / 5 A 250 V / 125 mA 250 V / 2 A 250 V / 5 A Type P/N 1SNA031821R0100 BNMS F125mA-3 1SNA031838R1200 BNMS F125mA-4 1SNA031822R0200 1SNA031823R0300 1SNA031824R0400 1SNA031825R0500 1SNA031826R0600 5/77 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 125 V / 125 mA 250 V / 125 mA 1SNA031827R0700 1SNA031828R1000 2 3 1 BNMS ST2 Type P/N BNMS ST1 BNMS ST2 1SNA031829R1100 1SNA031830R1600 End stops The end stops are mounted at the extremity of the terminal board assembly, giving additional support to the terminal blocks as markers. For various types of marking, refer to the marker section. BADL Description Type Order P/N Packaging Weight kg BAM2 BAMH BADH End stop DIN 3 BADL 9 mm 1SNA399903R0200 grey V0 End stop with screws DIN 3 BAM2 V0 10 mm 1SNA399967R0100 grey V0 BAM2 10 mm 1SNA206351R1600 grey V2 BAM2 V0 10 mm 1SNA296351R0000 beige V0 High end stop with screws DIN 1 BAMH 9,1 mm 1SNA114836R0000 and DIN 3 grey BAMH V0 9,1 mm 1SNA194836R0100 beige V0 High end stop with screws DIN 3 BADH 12 mm 1SNA116900R2700 grey 50 50 50 50 50 50 50 Mounting rails PR30 PR3.Z2 PR3.G2 PR5 PR4 Symmetrical zinc bichromate plated steel prepunched rail PR30 2 m 1SNA173220R0500 Symmetrical zinc bichromate plated steel rail PR3.Z2 2 m 1SNA174300R1700 White, symmetrical passivated galvanized steel rail PR3.G2 2 m 1SNA164800R0300 Symmetrical zinc bichromate plated steel rail PR5 2 m 1SNA168700R2200 Symmetrical zinc bichromate plated steel rail PR4 2 m 1SNA168500R1200 1 1 5 1 1 1 Test devices FC2 Test plug DIA. 2 mm FC2 1SNA007865R2600 10 Assembled jumper bar BJ612-... This accessory permits electrical connection between 2 to 70 blocks with 6 mm spacing placed side by side. It can be used with screw clamp or spring clamp blocks with 6 mm or 12 mm spacing. Interconnection of blocks not placed side by side is possible if teeth of the jumper bar have been cut in front of the blocks not to be connected. These teeth can be removed using pliers. Use of separator end sections before and after the jumper bar is required to preserve IP20 protection of the assembly. Assembled jumper bar 10 poles - 24 A BJ612-10 1SNA290488R0100 Assembled jumper bar 20 poles - 24 A BJ612-20 1SNA206754R0000 10 10 Separator end section Directly mounted on the rail beside the block, it permits to identify and make electrical insulation of product groups using jumper bars. Dimensions are the same as screw clamp blocks : width 70 mm and height on rail 67,5 mm with 2 mm spacing. SC612 Separator end section SC612 1SNA290474R0200 Distribution module This terminal block with BJ612-... jumper bars permits 2 polarities distribution (PCL side and process side) thanks to two separate circuits, each of them including : - one 4 mm² input, - two 2,5 mm² outputs - one double output for jumper bar BJ612-... 2,5 mm² .. 2-. 61 BJ 10 2,5 mm² 4 mm² .. 2-. 61 BJ It permits also the connection of ground to the rail though a 4 mm² input. 4 mm² 4 mm² D4/12-3... Rated voltage : 250 VAC-DC Rated current : 32 A (4 mm²) - 16 A (2,5 mm²) Recommended torque : 0,4 - 0,6 Nm Screw clamp distribution block sp. 12 mm D4/12-3-3 1SNA645031R2000 Spring clamp distribution block sp. 12 mm D4/12-3R-3R 1SNA645531R2200 5 5 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/78 Accessories PCMS PEF Comb-type jumper Identification label holders This accessory permits the electrical connection of 2 to 22 blocks. Designed to hold RPEV label (see opposite). No. Grey Red Blue Green/Yellow of UL94V0 UL94V0 UL94V0 UL94V0 poles 5 2 1SNA205491R2300 3 1SNA205495R2700 4 1SNA205499R0300 5 1SNA205503R0700 6 1SNA205507R0300 7 1SNA205511R2600 8 1SNA205515R2200 9 1SNA205519R0600 10 1SNA205523R2200 11 1SNA205527R2600 12 1SNA205531R2200 13 1SNA205535R2600 14 1SNA205539R0200 15 1SNA205543R0600 16 1SNA205547R0200 17 1SNA205551R0600 18 1SNA205555R0200 19 1SNA205559R1600 20 1SNA205563R0200 21 1SNA205567R0600 22 1SNA205571R0200 1SNA205492R2400 1SNA205496R2000 1SNA205500R1000 1SNA205504R0000 1SNA205508R1400 1SNA205512R2700 1SNA205516R2300 1SNA205520R0300 1SNA205524R2300 1SNA205528R0700 1SNA205532R2300 1SNA205536R2700 1SNA205540R1700 1SNA205544R0700 1SNA205548R1300 1SNA205552R0700 1SNA205556R0300 1SNA205560R1300 1SNA205564R0300 1SNA205568R1700 1SNA205572R0300 1SNA205493R2500 1SNA205497R2100 1SNA205501R0500 1SNA205505R0100 1SNA205509R1500 1SNA205513R2000 1SNA205517R2400 1SNA205521R2000 1SNA205525R2400 1SNA205529R0000 1SNA205533R2400 1SNA205537R2000 1SNA205541R0400 1SNA205545R0000 1SNA205549R1400 1SNA205553R0000 1SNA205557R0400 1SNA205561R0000 1SNA205565R0400 1SNA205569R1000 1SNA205573R0400 1SNA205494R2600 1SNA205498R0200 1SNA205502R0600 1SNA205506R0200 1SNA205510R0100 1SNA205514R2100 1SNA205518R0500 1SNA205522R2100 1SNA205526R2500 1SNA205530R0500 1SNA205534R2500 1SNA205538R0100 1SNA205542R0500 1SNA205546R0100 1SNA205550R1100 1SNA205554R0100 1SNA205558R1500 1SNA205562R0100 1SNA205566R0500 1SNA205570R1500 1SNA205574R0500 PEF * * Delivered with labels. 1SNA020568R0400 The label holders are removable and the labels can be changed easily. For mounting on PCB in a 3,7 mm diameter hole. RPEV Label for PEF 29 x 6 mm Sheets of 99 pre-cut labels RPEV ✓ Blank 1SNA173178R0700 DC PC Test device on screw head Comb-type jumper bar This patented device is mounted on the round screwdriver opening. It is used for trouble shooting, measuring and control for monitoring and repairing an installation, on blocks without a test socket. For this, the device receives an FC2 test plug. For mounting on a PCB block in a 2 mm diameter hole (no support leg). PC EIP blue for MA 2,5/5 blocks This accessory can be used only on the terminal blocks with at least one compression clamp connection. It permits the electrical connection of 2 to 10 blocks. Interconnection of non-consecutive blocks is possible by removing the teeth opposite the blocks which must not be connected. The comb-type jumper bars can be cut using pliers (or a saw) : in this case, the use of an insulating tip EIP is recommended. The comb is placed in the compression clamp before tightening the screws, above the eventual conductor. DCB 1SNA105028R2100 To be mounted on blocks series R900 and R910 : The DC's are differentiated by their colour : BJ BJS Jumper bar not assembled To be mounted on blocks series R910 : Screw + washer + post EV6D 1SNA168400R1600 Perforated jumper bar 8 poles BJS9 32 A 1SNA177583R1200 16 poles 1SNA177584R1300 BJS9 32 A RLV EIP Comb-type jumper bar PC9 Jumper bar Subassembly To connect terminal blocks, place the metal tube into screw + washer + post the top center hole on each terminal block to be connected. The metal tube contacts the terminal block's internal Perforated jumper bar connector bar. to be cut to length The perforated bar is cut to length and placed flat along the center opening of the series of terminal blocks. The screw is inserted into the perforated bar's hole which is located directly above the blocks being connected. The screw goes through the threaded metal tube and is screwed into the terminal block's internal connector bar. This completes the electrical connection to the perforated bar and connects the block. RL Insulating tip for comb Lengthwise marker Lengthwise marker Width 9 mm .354" Large area for writing. To be snapped onto the top of blocks. Blank marker for writing : RLV 1SNA103849R0300 1SNA113550R2000 15 A 10 poles 1SNA210160R1200 IDC jumper (insulation displacement jumper) Characteristics Wire size mm² / AWG IEC NFC Rigid Flexible Voltage V Current A Rated wire size mm² / AWG Working temperature °C Protection VDE 2,5 mm² 2,5 mm² CSA 14 AWG 600 600 26 15 2 2,5 mm 14 AWG -55°C -> +110°C IP20 / NEMA1 Quick-jump lets you interconnect screw clamp terminals of different sizes, levels and all manufacturers quickly and safely. Its insulation displacement technology makes it easy to use, fast, economical and does not require a special tool. Use as a jumper between relays, switches and other electronic components. ABB Quick-jump will fit any screw clamp type terminal block, from 6 mm .238" spacing and larger. How to use : connecting Quick-jump to your terminal 3 4 1 - Insert ABB Quick-jump into your terminal screw clamp. 2 - Tighten the terminal screw. 3 - Guide jumper wire through the V-shaped opening in the Quick-jump. 4 - Secure the wire by closing the Quick-jump lever with any flat nose pliers. 2 1 Adding a shunt in an installation : 1 - Insert ABB Quick-jump into your terminal screw clamp. 2 - Guide the terminal screw clamp into contact with the wire. 3 - Secure the wire by closing the Quick-jump lever with any flat nose pliers. 4 - Tighten the terminal screw. jumper Insulation displacement 5/79 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209 AD 2,5 4 3 1SNA114205R2000 1 2 Marking for Interface Modules Selection table Markers for modules : RC610 RC55 RC65 R500 1 Remove one of the side bands of the card. 2 Separate the chosen strip from the rest of the card. 3 Press the first marker in place, hold it and slide your thomb on the rest of the strip. Horizontal marking Vertical marking R600 R900 R910 R1800 Possible mounting : POSSIBLE POSSIBLE Recommended mounting : POSSIBLE Impossible mounting : Marking for terminal blocks 5 Standard RC marker cards (x) = Nb of cards in 5 mm spacing kit (x) = Nb of cards (x) = Nb of cards in 6 mm spacing kit in 6 mm spacing kit Marker sizes RC55 RC65 RC610 Blank cards 1SNA230000R1200 1SNA232000R0000 1SNA233000R0100 Horizontal marking 10 strips from 1 to 10 10 strips from 11 to 20 10 strips from 21 to 30 10 strips from 31 to 40 10 strips from 41 to 50 10 strips from 51 to 60 10 strips from 61 to 70 1SNA230002R0000 (5) 1SNA230003R0100 (2) 1SNA230004R0200 1SNA230005R0300 1SNA230006R0400 1SNA230007R0500 1SNA230008R1600 1SNA232002R2600 (5) 1SNA232003R2700 (2) 1SNA232004R2000 1SNA232005R2100 1SNA232006R2200 1SNA232007R2300 1SNA232008R0400 1SNA233002R2700 (25) 1SNA233003R2000 (10) 1SNA233004R2100 (6) 1SNA233005R2200 (4) 1SNA233006R2300 (3) 1SNA233007R2400 (2) 1SNA233008R0500 (2) From 1 to 100 From 101 to 200 1SNA230030R0700 (2) 1SNA230031R2400 1SNA232030R2500 (2) 1SNA232031R1200 1SNA233030R2600 (15) 1SNA233031R1300 (2) 20 times L1-L2-L3-N-PE 1SNA230131R2500 1SNA232131R1300 1SNA233131R1400 (2) Vertical marking 10 strips from 1 to 10 10 strips from 11 to 20 10 strips from 21 to 30 10 strips from 31 to 40 1SNA230041R0600 1SNA230042R0700 1SNA230043R0000 1SNA230044R0100 1SNA232041R2400 1SNA232042R2500 1SNA232043R2600 1SNA232044R2700 1SNA233041R2500 (5) 1SNA233042R2600 (3) 1SNA233043R2700 (2) 1SNA233044R2000 (2) From 1 to 100 1SNA230060R1500 1SNA232060R0300 1SNA233060R0400 (8) Marking kit RC 5 mm spacing or 6 mm spacing Box with 100 cards with 18 various part numbers (see table next page) Description Type Order P/N Packaging Weight kg Refilable box of 100 cards of 18 RC markers Box with 100 cards RC 5 mm spacing 1SNA400085R2700 Refill for box RC 5 mm 1SNA400145R0700 1 1 Box with 100 cards RC 6 mm spacing 1SNA400084R2600 Refill for box RC 6 mm 1SNA400144R0600 1 1 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 5/80
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2013:11:28 11:11:34+01:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2014:01:27 11:53:06+05:30 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Instance ID : uuid:3da28e89-4f94-4306-a650-e1f9cc482686 Original Document ID : adobe:docid:indd:df79d2d0-e133-11e0-b6ce-b704341a6fd2 Document ID : xmp.id:8D46FAE31258E311B1F591687500FAA0 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:68CBE41A0746E3119A5BE3FDA3557FBC Derived From Document ID : xmp.did:1172188A6645E3119A3D8075F48CC363 Derived From Original Document ID: adobe:docid:indd:df79d2d0-e133-11e0-b6ce-b704341a6fd2 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:11:28 11:11:51+01:00 Metadata Date : 2014:01:27 11:53:06+05:30 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Layout : TwoPageLeft Page Mode : UseOutlines Page Count : 80EXIF Metadata provided by EXIF.tools