GRX PCBL 346S Cable Spec Submittal Part #369596b Brochure

2016-10-06

: Pdf 97486-Brochure 97486-Brochure B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LUTRON®Cable Accessories
369-596b 1 11.29.11
GRX-PCBL-346S Cable
Plenum rated cable for use with the following Lutron
systems:
- GRAFIK Eye® 3000
- GRAFIK Eye® QS
- Energi Savr NodeTM
• Plenum rated for use in ceilings and enclosures
that are also used by the building air distribution
system to transport environmental air.
Specifications
Listed as type CL3P (Class 3 Plenum Cable) or CMP
cULu s .
• Available in 500 ft (150 m) spool.
• Five conductors:
Common – 18 AWG (0.75 mm2)
Power – 18 AWG (0.75 mm2)
MUX Data – 22 AWG (0.25 mm2)
_ Data – 22 AWG (0.25 mm2)
Drain Wire – 24 AWG (0.2 mm2)
• Total Outer Jacket Diameter: 0.17 in (4.37 mm).
• 300 V Rated.
• Plenum sheath, 75 °C rated.
• UL Listed.
• Rated FT6.
cULu s or CSA Listed.
• Capacitance of 22 AWG (0.25 mm2) Twisted
Wire Pair:
-Conductor to shield: 48 pf/ft max
-Conductor to Conductor: 25 pf/ft max
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
cable-3 11.04.11
AccessoriesCable
LUTRON
GRX-PCBL-346S Cable
GRX-PCBL-46L Cable
22 AWG (0.25 mm2)
22 AWG (0.25 mm2)
18 AWG (0.75 mm2)
18 AWG (0.75 mm2)
12 AWG (4.0 mm2)
18 AWG (0.75 mm2)
12 AWG (4.0 mm2)
22 AWG (0.25 mm2)
22 AWG (0.25 mm2)
24 AWG (0.2 mm2) Drain
0.17 in (4.37 mm)
TWP
24 AWG (0.2 mm2) Drain
0.30 in (7.75 mm)
TWP
Description
For use with GRAFIK Eye® 3000 Systems.
Plenum rated for use in ceilings and enclosures
that are also used by the building air distribution
system to transport environmental air.
Specifications
Listed as cable type CL3P (Class 3 Plenum Cable)
or CMP CULUS.
Available in 500 ft (150 m) spool.
Five conductors:
Common – 18 AWG (0.75 mm2)
Power – 18 AWG (0.75 mm2)
MUX Data – 22 AWG (0.25 mm2)
MUX Data – 22 AWG (0.25 mm2)
Drain Wire – 24 AWG (0.2 mm2)
Total Outer Jacket Diameter: 0.23 in (5.75 mm).
300 V Rated.
Plenum sheath, 75 °C rated.
UL/CSA Listed.
Rated FT6.
Description
For use with GRAFIK Eye® 4000, GRAFIK
5000/6000/7000, Digital microWATTTM, and
HomeWorks InteractiveTM Systems.
Plenum rated for use in ceilings and enclosures
that are also used by the building air distribution
system to transport environmental air.
Specifications
Listed as cable type CL3P (Class 3 Plenum
Cable) or CMP CULUS.
Available in 250 ft (75 m) or 500 ft (150 m) spools.
Six conductors:
Common – 12 AWG (4.0 mm2)
Power – 12 AWG (4.0 mm2)
MUX Data – 22 AWG (0.25 mm2)
MUX Data – 22 AWG (0.25 mm2)
Sense Line – 18 AWG (0.75 mm2)
Drain Wire – 24 AWG (0.2 mm2)
Total Outer Jacket Diameter: 0.30 in (7.75 mm).
300 V Rated.
Plenum sheath, 75 °C rated.
UL/CSA Listed.
Rated FT6.
}Twisted Wire Pair
}Twisted Wire Pair
1
* Please refer to the Product Specication Submittal Sheets or Product Installation Guides for control link
wiring distance maximums and other limitations.
}Twisted wire pair
1
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
LUTRON®Cable Accessories
369-596b 2 11.29.11
GRX-PCBL-46L Cable
Plenum rated cable for use with the following Lutron
systems:
- GRAFIK Eye® 4000
- LCP128TM
- Softswitch128®
- GRAFIK 5000TM
- GRAFIK 6000®
- GRAFIK 7000TM
- Quantum®
- HomeWorks InteractiveTM
- HomeWorks® QS
- Energi Savr NodeTM
• Plenum rated for use in ceilings and enclosures
that are also used by the building air distribution
system to transport environmental air.
Specifications
Listed as type CL3P (Class 3 Plenum Cable) or CMP
cULu s .
• Available in 250 ft (75 m) or 500 ft (150 m) spools.
• Six conductors:
Common – 12 AWG (4.0 mm2)
Power – 12 AWG (4.0 mm2)
MUX Data – 22 AWG (0.25 mm2)
_ Data – 22 AWG (0.25 mm2)
Sense Line – 18 AWG (0.75 mm2)
Drain Wire – 24 AWG (0.2 mm2)
• Total Outer Jacket Diameter: 0.30 in (7.75 mm).
• 300 V Rated.
• Plenum sheath, 75 °C rated.
• UL Listed.
• Rated FT6.
cULu s or CSA Listed.
• Capacitance of 22 AWG (0.25 mm2) Twisted
Wire Pair:
-Conductor to shield: 48 pf/ft max
-Conductor to Conductor: 25 pf/ft max
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
cable-3 11.04.11
AccessoriesCable
LUTRON
GRX-PCBL-346S Cable
GRX-PCBL-46L Cable
22 AWG (0.25 mm2)
22 AWG (0.25 mm2)
18 AWG (0.75 mm2)
18 AWG (0.75 mm2)
12 AWG (4.0 mm2)
18 AWG (0.75 mm2)
12 AWG (4.0 mm2)
22 AWG (0.25 mm2)
22 AWG (0.25 mm2)
24 AWG (0.2 mm2) Drain
0.17 in (4.37 mm)
TWP
24 AWG (0.2 mm2) Drain
0.30 in (7.75 mm)
TWP
Description
For use with GRAFIK Eye® 3000 Systems.
Plenum rated for use in ceilings and enclosures
that are also used by the building air distribution
system to transport environmental air.
Specifications
Listed as cable type CL3P (Class 3 Plenum Cable)
or CMP CULUS.
Available in 500 ft (150 m) spool.
Five conductors:
Common – 18 AWG (0.75 mm2)
Power – 18 AWG (0.75 mm2)
MUX Data – 22 AWG (0.25 mm2)
MUX Data – 22 AWG (0.25 mm2)
Drain Wire – 24 AWG (0.2 mm2)
Total Outer Jacket Diameter: 0.23 in (5.75 mm).
300 V Rated.
Plenum sheath, 75 °C rated.
UL/CSA Listed.
Rated FT6.
Description
For use with GRAFIK Eye® 4000, GRAFIK
5000/6000/7000, Digital microWATTTM, and
HomeWorks InteractiveTM Systems.
Plenum rated for use in ceilings and enclosures
that are also used by the building air distribution
system to transport environmental air.
Specifications
Listed as cable type CL3P (Class 3 Plenum
Cable) or CMP CULUS.
Available in 250 ft (75 m) or 500 ft (150 m) spools.
Six conductors:
Common – 12 AWG (4.0 mm2)
Power – 12 AWG (4.0 mm2)
MUX Data – 22 AWG (0.25 mm2)
MUX Data – 22 AWG (0.25 mm2)
Sense Line – 18 AWG (0.75 mm2)
Drain Wire – 24 AWG (0.2 mm2)
Total Outer Jacket Diameter: 0.30 in (7.75 mm).
300 V Rated.
Plenum sheath, 75 °C rated.
UL/CSA Listed.
Rated FT6.
}Twisted Wire Pair
}Twisted Wire Pair
1
* Please refer to the Product Specication Submittal Sheets or Product Installation Guides for control link
wiring distance maximums and other limitations.
}Twisted wire pair