99333 Catalog

2014-09-27

: Pdf 99333-Catalog 99333-Catalog 781063 Batch8 unilog

Open the PDF directly: View PDF PDF.
Page Count: 388

Download99333-Catalog
Open PDF In BrowserView PDF
ADALET
A S C O T T F E T Z E R C O M PA N Y

INDUSTRIAL ELECTRICAL AND
EXPLOSIONPROOF ENCLOSURE SYSTEMS

R
FO

D
VE
O
PR
AP GE 2
A
EC
EL EE P
N
S
CE
#NCAT01

ITS
N
U

REV. D

14562 Pg 00-00 12/2/00 12:36 PM Page 1

Designing Our Products Around Yours
A SCOTT FETZER COMPANY

by Fax

1
4

REGISTER

7

8

2
5

3

6
9

Just photocopy this form and
fax your request for information now!

(216) 267-1681
Your local Adalet Representative is:

Sales and Marketing

ATTENTION:
FROM:

TITLE:

COMPANY:

ADDRESS:

CITY:

PHONE: (

STATE:

)

FAX: (

ZIP:

)

EMAIL ADDRESS

Check One

❑
❑
❑

❑
❑
❑

Engineering / Design Firm
OEM
Contractor

❑

I am interested in ADALET products:

Distributor
End User
Other ________________

Please have your sales representative call me.

Please send an additional catalog to the following person:
NAME:

TITLE:

COMPANY:
ADDRESS:
CITY:

STATE:

SM

ADALET Enclosure Systems • Designing Our Products Around Yours

ZIP:

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Pg 01-04 12/9/01 3:28 PM Page 1

Table of Contents
Pages 1A–1 To 1C–4
SECTION 1

Industrial Electrical Enclosures
1A Stainless Steel Enclosures
1B Aluminum Enclosures
1C Accessories for Stainless Steel &
Aluminum Enclosures

Pages 2A–1 To 2A–20
SECTION 2

Fiberglass Enclosures

3A Principles, Markings, and How to Select an
Increased Safety Terminal Enclosure
3B Increased Safety Terminal Enclosures: TN4
Series, TN4 Expanded Series, TSC Series,
TFG Series

Pages 3A–1 To 3E–4
SECTION 3

Increased Safety Products

3C HV Series - High Voltage Junction Boxes
3D CN Series
3E Intrinsically Safe Terminal Enclosures

Pages 4A–1 To 4B–1
SECTION 4

Explosionproof Instrument Housings
4A Instrument Housings
4B Digital Instrument Enclosures

5A Explosionproof External Flanged Enclosures
and Accessories
5B Explosionproof Internal Flanged Enclosures
and Accessories

Pages 5A–1 To 5E–9

5C Explosionproof Fire Alarm Stations
5D Dust and Watertight Enclosures
5E Multi-Hub Boxes, Thermocouple Head Box

Explosionproof Threaded
Cover Enclosures

SECTION 6

Pages 6A–1 To 6A–15

AutoCAD drawings available upon request. Please contact Adalet engineering department.

ADALET Enclosure Systems • Designing Our Products Around Yours

SECTION 5

Explosionproof, Dust-Tight,
Watertight Enclosures & Accessories

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

1

15599 Pg 01-04 12/9/01 3:28 PM Page 2

Now CENELEC Approved
XCEX EExd IIB
Includes pushbuttons, selector switches, potentiometers and close up plugs
when installed in Adalet enclosures.
see SECTION 5A

XJ_X Screw Cover Series EExd IIB+H2
Includes pushbuttons, selector switches, potentiometers and close up plugs
when installed in Adalet enclosures.
see SECTION 6A

Instrument Housings EExd IIC
(except XDHLX is EExd IIB+H2)
XIHX / XDHX series
XIHMX / XDHMX series
XIHLX / XDHLX series
see SECTION 4A

Increased Safety Terminal Enclosures EEx'e' II
see SECTION 3A

2
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

Explosionproof Control Stations

Pages 7A–1 To 7C–7

7A FS Control
7B PriStar
7C Factory-Sealed Control Stations/OmniStar
3

8A
8B
8C
8D
8E

Pages 8–A1 To 8E–1
SECTION 8

Motor Control

SECTION 7

15599 Pg 01-04 12/11/01 6:58 PM Page 3

Panelboards
Circuit Breakers
Motor Starters
IEC Motor Control
Manual Motor Starters

Pages 9–A1 To 9A–21

Couplers, Plugs, Receptacles

Pages 11–A1 To 11A–40

Hazardous Location Definitions

Pages 12–A1 To 12A–6

SECTION 11

Pages 10–A1 To 10A–20

SECTION 12

Explosionproof Fittings,
Accessories

SECTION 10

SECTION 9

Explosionproof Pilot Devices

AutoCAD drawings available upon request. Please contact Adalet engineering department.

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

3

INDEX

Index

15599 Pg 01-04 12/9/01 3:28 PM Page 4

Quick Reference Guide
METHODS OF PROTECTION
Area
Division 1

Division 2

Area
Zone 0
Zone 1

Zone 2

Protection Method

UL

CSA

CENELEC

Explosionproof
Intrinsically Safe
(2 Fault)
Purge/Pressurized
(Type X or Y)
Nonincendive
Non-sparking device
Purge/Pressurized
(Type Z)
Hermetically sealed
Any Class I,
Division 1 Method
Protection Method
Intrinsically Safe 'ia'
(2 Fault)
Flameproof 'd'
Increased Safety 'e'
Intrinsically Safe 'ib'
(1 Fault)0
Encapsulation 'm'
Oil Immersion 'o'
Purged/Pressurized 'p'
Powder filling 'q'
Any Zone 0 Method
Non-sparking 'nA'
Hermetically sealed 'nC'
Nonincendive 'nC'
Restricted breathing 'nR'
Any Zone 0 or 1 Method

ANSI/UL 1203

CSA-30

--

--

ANSI/UL 913

CSA-157

--

--

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604
UL 1604

CSA-213
CSA-213

---

---

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604

CSA-213

--

--

--

--

--

--

UL (AEx)

CSA (Ex)

CENELEC (EEx)

IEC (Ex)

UL 2279 Pt. 11

CSA-E79-18

EN 50028

IEC 60 079-18

UL 2279 Pt. 1
UL 2279 Pt. 7

CSA-E79-1
CSA-E79-7

EN 50018
EN 50019

IEC 60 079-1
IEC 60 079-7

UL 2279 Pt. 11

CSA-E79-11

EN 50020

IEC 60 079-11

UL 2279 Pt. 18
UL 2279
UL 2279 Pt. 2
UL 2279
-UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
--

CSA-E79-18
CSA-E79-6
CSA-E79-2
CSA-E79-5
-CSA-E79-15
CSA-E79-15
CSA-E79-15
CSA-E79-15
--

EN 50028
EN 50015
EN 50016
EN 50017
-prEN 50021
prEN 50021
prEN 50021
prEN 50021
--

IEC 60 079-18
IEC 60 079-6
IEC 60 079-2
IEC 60 079-5
-IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
--

TEMPERATURE CLASSES

AREA CLASSIFICATIONS
Ignitable Materials
Present Continuously

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Zone 0
(Zone 20 Dust)
Zone 0
Division 1

Zone 1
(Zone 21 Dust)
Zone 1
Division 1

Zone 2
(Zone 22 Dust)
Zone 2
Division 2

IEC/CENELEC
NEC 505
NEC 500

ATEX Classification by Group & Category According to Use
Ignitable Materials
Present Continuously
Equipment Group II Category 1 Equipment
(surface)
Equipment Group I
Category M1 Equipment
(mining)

IEC

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Category 2 Equipment

Category 3 Equipment

Category M2 Equipment

—

GAS GROUPINGS
Gas, Dust or Fiber

NEC 505/IEC/CENELEC

NEC 500

Acetylene
Hydrogen
Ethylene
Propane
Methane
Metal Dust
Coal Dust
Grain Dust
Fibers

Group IIC
Group IIC/Group IIB+H2
Group IIB
Group IIA
Group I (firedamp)
None
None
None
None

Class I/Group A
Class I/Group B
Class I/Group C
Class I/Group D
Class I/Group D
Class II/Group E
Class II/Group F
Class II/Group G
Class III

ACRONYMS
CENELEC - European Committee for Electrotechnical Standardization
IEC - International Electrotechnical Commission
NEC - National Electrical Code
U.L. - Underwriters Laboratories
C.S.A. - Canadian Standards Association
FM - Factory Mutual
BASEEFA - British Approvals Service for Electrical Apparatus in
Flammable Atmospheres
NFPA - National Fire Protection Agency
ISO - International Organization for Standardization
ANSI - American National Standard Institute
ATEX - Atmospheres Explosibles

Maximum
Surface
Temperature

NEC 505
IEC
CENELEC

450°C
300°C
280°C
260°C
230°C
215°C
200°C
180°C
165°C
160°C
135°C
120°C
100°C
85°C

T1
T2

T3

T4
T5
T6

NEC 500
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

INGRESS PROTECTION (IP XX) CODES
#

First Number
(Protection against Solid Bodies)

Second Number
(Protection against Liquids)

0
1
2
3
4
5
6
7
8

No protection
Objects greater than 50mm
Objects greater than 12mm
Objects greater than 2.5mm
Object greater than 1mm
Dust Protected
Dust-tight
---

No protection
Vertically dripping water
75-90 Deg. dripping water
Sprayed water
Splashed water
Water jets
Heavy seas
Effects of immersion
Indefinite immersion

15599 Sec.1 12/9/01 10:39 AM Page 5

1A–1

NEMA Type 4X JIC Stainless Steel Enclosures – Continuous Hinge Cover

These enclosures are suitable for use in areas such as
petrochemical plants, dairies, breweries, food processing
areas and similar environments where they are subject to
frequent high pressure hosing and generally wet
conditions. They are also designed for use in areas where
severe corrosion problems exist. Type 316 stainless steel
enclosures are also suitable for use in offshore
applications. (Not submersible.)

Construction
Adalet’s JN4XHSS enclosures are available in Type 304 or
Type 316 stainless steel with a #3 - #4 brush finish.
(Replace -SS with -SS6 in catalog number when ordering
Type 316 stainless steel.) All seams are continuously
welded and ground to a smooth finish. Each enclosure
comes complete with four 10-32 weld nuts (for mounting
optional panels). Grounding studs are provided on the
inside of the box and door, and wall mounting back
brackets are welded on the top and bottom outside. The
JN4XHSS cover is sealed with a neoprene gasket and is
secured to the enclosure with a continuous stainless steel
piano hinge on one side and stainless steel door clamping
hardware on three sides. There are no knock-outs or holes
in the cover or body.

Panels
Optional panels are available. Panels are fabricated from
#14 ga. cold-rolled steel.

Finish
All enclosures are made from Type 304 or Type 316
stainless steel with a #3 - #4 brush finish. Panels are
finished with a high gloss white paint.

Standards

Shown with optional hinged cover and panel.

All JN4XHSS enclosures conform to the National Electrical
Manufacturers Association (NEMA) standard for Type 3
(Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R
(Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and
Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight
and Dust-tight) enclosures. These enclosures conform to
Joint Industry Council (JIC) standard EGP-1-1967. They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders
Application
Adalet’s JN4XHSS series wall-mounted JIC enclosures are
designed to provide protection, indoors and outdoors,
against dust, dirt, oil and water for items such as
pneumatic or hydraulic instruments, transformers, and
junction wiring.

Custom units in special sizes or with punching can be
supplied.
For Type 316 stainless steel enclosures, add 6 after SS
(i.e. JN4XHSS6)

5
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 6

NEMA Type 4X JIC Stainless Steel Enclosures – Continuous Hinge Cover

1A–2
Enclosure
Catalog Number

Gauge

A

B

C

Panel
Catalog No.

D

E

F

G

Mounting
H

M

Clamps
N

JN4XHSS-060403

16

6.00

4.00

3.00

06P04

4.88

2.88

2.55

6.75

2.00

3.00

2.00

JN4XHSS-080604

14

8.00

6.00

4.00

08P06

6.88

4.88

3.55

8.75

4.00

4.00

3.00

JN4XHSS-060404

16

6.00

4.00

4.00

06P04

4.88

2.88

3.55

6.75

2.00

3.00

2.00

JN4XHSS-060604

16

6.00

6.00

4.00

06P06

4.88

4.88

3.55

6.75

4.00

3.00

3.00

JN4XHSS-080804

14

8.00

8.00

4.00

08P08

6.88

6.88

3.55

8.75

6.00

4.00

4.00

JN4XHSS-100804

14

10.00

8.00

4.00

10P08

8.88

6.88

3.55

10.75

6.00

1.63

4.00

JN4XHSS-121005

14

12.00

10.00

5.00

12P10

10.88

8.88

4.55

12.75

8.00

3.63

2.63

JN4XHSS-080606

14

8.00

6.00

6.00

08P06

6.88

4.88

5.55

8.75

4.00

4.00

3.00

JN4XHSS-100806

14

10.00

8.00

6.00

10P08

8.88

6.88

5.55

10.75

6.00

1.63

4.00

JN4XHSS-101006

14

10.00

10.00

6.00

10P10

8.88

8.88

5.55

10.75

8.00

1.63

2.63

JN4XHSS-121206

14

12.00

12.00

6.00

12P12

10.88

10.88

5.55

12.75

10.00

3.63

3.00

JN4XHSS-140806

14

14.00

8.00

6.00

14P08

12.88

6.88

5.55

14.75

6.00

3.63

4.00

JN4XHSS-141206

14

14.00

12.00

6.00

14P12

12.88

10.88

5.55

14.75

10.00

3.63

3.00

JN4XHSS-161406

14

16.00

14.00

6.00

16P14

14.88

12.88

5.55

16.75

12.00

1.63

4.13

JN4XHSS-121008

14

12.00

10.00

8.00

12P10

10.88

8.88

7.55

12.75

8.00

3.63

2.63

JN4XHSS-141208

14

14.00

12.00

8.00

14P12

12.88

10.88

7.55

14.75

10.00

3.63

4.13

JN4XHSS-161408

14

16.00

14.00

8.00

16P14

14.88

12.88

7.55

16.75

12.00

1.63

4.13

JN4XHSS-161410

14

16.00

14.00

10.00

16P14

14.88

12.88

9.55

16.75

12.00

1.63

4.13

All dimensions in inches

For Type 316 stainless steel enclosures,
add 6 after SS. (i.e. JN4XHSS6)

6
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 7

1A–3

NEMA Type 4X JIC Stainless Steel Enclosures – Lift Off Cover

These enclosures are suitable for use in areas such as
petrochemical plants, dairies, breweries, food processing
areas and similar environments where they are subject to
frequent high pressure hosing and generally wet
conditions. They are also designed for use in areas where
severe corrosion problems exist. Type 316 stainless steel
enclosures are also suitable for use in offshore
applications. (Not submersible.)

Construction
Adalet’s JN4XSS enclosures are available in Type 304 or
Type 316 stainless steel with a #3 - #4 brush finish.
(Replace -XSS with -XSS6 in catalog number when
ordering Type 316 stainless steel.) All seams are
continuously welded and ground to a smooth finish. Each
enclosure comes complete with four 10-32 weld nuts (for
mounting optional panels). Grounding studs are provided
on the inside of the box and door, and wall mounting back
brackets are welded on the top and bottom outside. The
JN4XSS cover is sealed with a neoprene gasket and is
secured to the enclosure with a continuous stainless steel
piano hinge on one side and stainless steel door clamping
hardware on three sides. There are no knock-outs or holes
in the cover or body.

Panels
Optional panels are available. Panels are fabricated from
cold-rolled steel.

Finish
All enclosures are made from Type 304 or Type 316
stainless steel with a #3 - #4 brush finish. Panels are
finished with a high gloss white paint.

Standards

Shown with optional panel.

All JN4XSS enclosures conform to the National Electrical
Manufacturers Association (NEMA) standard for Type 3
(Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R
(Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and
Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight
and Dust-tight) enclosures. These enclosures conform to
Joint Industry Council (JIC) standard EGP-1-1967. They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders
Application
Adalet’s JN4XSS series wall-mounted JIC enclosures are
designed to provide protection, indoors and outdoors,
against dust, dirt, oil and water for items such as
pneumatic or hydraulic instruments, transformers, and
junction wiring.

Custom units in special sizes or with punching can be
supplied.
For Type 316 stainless steel enclosures, replace SS
with SS6 in catalog number (i.e. JN4XSS6)

7
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 8

NEMA Type 4X JIC Stainless Steel Enclosures – Lift Off Cover

1A–4
Enclosure
Catalog Number

Gauge

A

B

C

Panel
Catalog No.

D

E

F

G

Mounting
H

M

Clamps
N

JN4XSS-060403

16

6.00

4.00

3.00

06P04

4.88

2.88

2.55

6.75

2.00

3.00

2.00

JN4XSS-080604

14

8.00

6.00

4.00

08P06

6.88

4.88

3.55

8.75

4.00

4.00

3.00

JN4XSS-060404

16

6.00

4.00

4.00

06P04

4.88

2.88

3.55

6.75

2.00

3.00

2.00

JN4XSS-060604

16

6.00

6.00

4.00

06P06

4.88

4.88

3.55

6.75

4.00

3.00

3.00

JN4XSS-080804

14

8.00

8.00

4.00

08P08

6.88

6.88

3.55

8.75

6.00

4.00

4.00

JN4XSS-100804

14

10.00

8.00

4.00

10P08

8.88

6.88

3.55

10.75

6.00

1.63

4.00

JN4XSS-121005

14

12.00

10.00

5.00

12P10

10.88

8.88

4.55

12.75

8.00

3.63

2.63

JN4XSS-080606

14

8.00

6.00

6.00

08P06

6.88

4.88

5.55

8.75

4.00

4.00

3.00

JN4XSS-100806

14

10.00

8.00

6.00

10P08

8.88

6.88

5.55

10.75

6.00

1.63

4.00

JN4XSS-101006

14

10.00

10.00

6.00

10P10

8.88

8.88

5.55

10.75

8.00

1.63

2.63

JN4XSS-121206

14

12.00

12.00

6.00

12P12

10.88

10.88

5.55

12.75

10.00

3.63

3.00

JN4XSS-140806

14

14.00

8.00

6.00

14P08

12.88

6.88

5.55

14.75

6.00

3.63

4.00

JN4XSS-141206

14

14.00

12.00

6.00

14P12

12.88

10.88

5.55

14.75

10.00

3.63

3.00

JN4XSS-161406

14

16.00

14.00

6.00

16P14

14.88

12.88

5.55

16.75

12.00

1.63

4.13

JN4XSS-121008

14

12.00

10.00

8.00

12P10

10.88

8.88

7.55

12.75

8.00

3.63

2.63

JN4XSS-141208

14

14.00

12.00

8.00

14P12

12.88

10.88

7.55

14.75

10.00

3.63

4.13

JN4XSS-161408

14

16.00

14.00

8.00

16P14

14.88

12.88

7.55

16.75

12.00

1.63

4.13

JN4XSS-161410

14

16.00

14.00

10.00

16P14

14.88

12.88

9.55

16.75

12.00

1.63

4.13

All dimensions in inches

For Type 316 stainless steel enclosures, replace
SS with SS6 in catalog number (i.e. JN4XSS6)

8
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 9

NEMA Type 4X Stainless Steel Single Door Enclosures

1A–5

Application
Adalet’s N4X single-door wall-mounted enclosures are
used indoors and outdoors to house such items as pilot
devices, electronic/electrical controls, instrumentation
systems, and pneumatic, hydraulic, and machine tool
controls.
These enclosures are designed to provide protection against
dust, dirt, oil and water. They are for use in petrochemical
plants, dairies, breweries, food processing areas and similar
environments where they are subject to frequent high
pressure hosing and generally wet conditions. They are also
designed for use in areas where severe corrosion problems
exist. Type 316 enclosures are also suitable for use in
offshore applications. (Not submersible.)

Construction
Adalet’s N4X enclosures are available in either Type 304
or Type 316 stainless steel with a #3 - #4 brush finish.
(Replace N4X with N4X6 in catalog number when ordering
Type 316 stainless steel.) The N4X has continuously
welded seams ground to a smooth finish. The N4X
enclosure has a folded lip around the door opening to
provide complete and maximum gasket contact, and to
prevent liquids from dripping into the enclosure when the
door is open. Each enclosure comes complete with 3/8
collar studs (for mounting optional panels), 1/4-20
grounding studs, padlock hasp and staple, and optional
print pocket.
Large N4X enclosures come complete with additional
panel mounting studs and maintain a rigid construction
through the use of door and body stiffeners. There are no
knock-outs or holes in the door or body. Print pockets are
furnished upon request and will be shipped loose.

Panels
Optional panels are available. Panels are fabricated from
12 ga. cold-rolled steel.

Finish
All enclosures are made from Type 304 or Type 316
stainless steel with a #3 - #4 brush finish. Optional panels
are white.

Standards
All N4X enclosures conform to the National Electrical
Manufacturers Association (NEMA) standard for Type 3
(Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R
(Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and
Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight
and Dust-tight) enclosures. These enclosures conform to
Joint Industry Council (JIC) standard EGP-1-1967. They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders
Custom units in special sizes or with punching can be
supplied.
9
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 10

NEMA Type 4X Stainless Steel Single Door Enclosures

1A–6
Enclosure

Panel
No. of
Clamps

F

6.00

4

1.25

—

—

V1612

13.00

9.00

6.00

4

3.00

—

—

V1616

13.00

13.00

20.00

6.00

4

3.00

—

—

V2016

13.00

17.00

16.00

6.00

4

3.00

—

—

V2016

17.00

13.00

20.00

20.00

6.00

4

3.00

—

—

V2020

17.00

17.00

20.00

24.00

6.00

4

3.00

—

—

V2420

17.00

21.00

14

24.00

12.00

6.00

5

1.25

—

—

V2412

21.00

9.00

14

24.00

16.00

6.00

5

3.00

—

—

V2416

21.00

13.00

16

14

24.00

20.00

6.00

5

3.00

—

—

V2420

21.00

17.00

16

14

24.00

24.00

6.00

5

3.00

—

—

V2424

21.00

21.00

-302006

14

14

30.00

20.00

6.00

5

3.00

—

—

V3020

27.00

17.00

-302406

14

14

30.00

24.00

6.00

5

3.00

—

—

V3024

27.00

21.00

-362406

14

14

36.00

24.00

6.00

5

3.00

—

—

V3624

33.00

21.00

-363006

14

14

36.00

30.00

6.00

7

3.00

1

—

V3630

33.00

27.00

-161208

16

14

16.00

12.00

8.00

4

1.25

—

—

V1612

13.00

9.00

-161608

16

14

16.00

16.00

8.00

4

3.00

—

—

V1616

13.00

13.00

-162008

16

14

16.00

20.00

8.00

4

3.00

—

—

V2016

13.00

17.00

-201608

16

14

20.00

16.00

8.00

4

3.00

—

—

V2016

17.00

13.00

-202008

16

14

20.00

20.00

8.00

4

3.00

—

—

V2020

17.00

17.00

-202408

16

14

20.00

24.00

8.00

4

3.00

—

—

V2420

17.00

21.00

-241608

16

14

24.00

16.00

8.00

5

3.00

—

—

V2416

21.00

13.00

Catalog # Prefixes

Gauge Thickness

Box Dimensions
B
C

N4X or N4X6

Box

Door

A

-161206

16

14

16.00

12.00

-161606

16

14

16.00

16.00

-162006

16

14

16.00

-201606

16

14

20.00

-202006

16

14

-202406

16

14

-241206

16

-241606

16

-242006
-242406

Box Stiff. Door Stiff.
Qty
Qty

Panel Catalog #
(optional)

Panel Dimensions
X
Y

10
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 11

NEMA Type 4X Stainless Steel Single Door Enclosures
Panel
No. of
Clamps

F

8.00

5

3.00

—

—

V2420

21.00

17.00

8.00

5

3.00

—

—

V2424

21.00

21.00

30.00

8.00

7

3.00

—

—

V3024

21.00

27.00

30.00

20.00

8.00

5

3.00

—

—

V3020

27.00

17.00

14

30.00

24.00

8.00

5

3.00

—

—

V3024

27.00

21.00

14

14

30.00

30.00

8.00

7

3.00

1

—

V3030

27.00

27.00

-362408

14

14

36.00

24.00

8.00

5

3.00

—

—

V3624

33.00

21.0

-363008

14

14

36.00

30.00

8.00

7

3.00

1

—

V3630

33.00

27.00

-363608

14

14

36.00

36.00

8.00

7

3.00

1

1

V3636

33.00

33.00

-423008

14

14

42.00

30.00

8.00

8

3.00

—

—

V4230

39.00

27.00

-423608

14

14

42.00

36.00

8.00

8

3.00

1

1

V4236

39.00

33.00

-483608

14

14

48.00

36.00

8.00

8

3.00

—

—

V4836

45.00

33.00

-201610

16

14

20.00

16.00

10.00

4

3.00

—

—

V2016

17.00

13.00

-202010

16

14

20.00

20.00

10.00

4

3.00

—

—

V2020

17.00

17.00

-242010

16

14

24.00

20.00

10.00

5

3.00

—

—

V2420

21.00

17.00

-242410

16

14

24.00

24.00

10.00

5

3.00

—

—

V2424

21.00

21.00

-302410

14

14

30.00

24.00

10.00

5

3.00

—

—

V3024

27.00

21.00

-362410

14

14

36.00

24.00

10.00

5

3.00

—

—

V3624

33.00

21.00

-363010

14

14

36.00

30.00

10.00

7

3.00

1

—

V3630

33.00

27.00

-423010

14

14

42.00

30.00

10.00

8

3.00

1

1

V4230

39.00

27.00

-423610

14

14

42.00

36.00

10.00

8

3.00

1

1

V4236

39.00

33.00

-483610

14

14

48.00

36.00

10.00

8

3.00

—

—

V4836

45.00

33.00

-603610

14

14

60.00

36.00

10.00

9

3.00

—

—

V6036

57.00

33.00

-201612

16

14

20.00

16.00

12.00

4

3.00

—

—

V2016

17.00

13.00

-242012

16

14

24.00

20.00

12.00

5

3.00

—

—

V2420

21.00

17.00

-242412

16

14

24.00

24.00

12.00

5

3.00

—

—

V2424

21.00

21.00

-302412

14

14

30.00

24.00

12.00

5

3.00

—

—

V3024

27.00

21.00

-303012

14

14

30.00

30.00

12.00

7

3.00

1

—

V3030

27.00

27.00

-362412

14

14

36.00

24.00

12.00

5

3.00

—

—

V3624

33.00

21.00

-363012

14

14

36.00

30.00

12.00

7

3.00

1

1

V3630

33.00

27.00

-363612

14

14

36.00

36.00

12.00

7

3.00

1

1

V3636

33.00

33.00

-423012

14

14

42.00

30.00

12.00

8

3.00

1

1

V4230

39.00

27.00

-423612

14

14

42.00

36.00

12.00

8

3.00

—

—

V4236

39.00

33.00

-483612

14

14

48.00

36.00

12.00

8

3.00

—

—

V4836

45.00

33.00

-603612

14

14

60.00

36.00

12.00

9

3.00

—

—

V6036

57.00

33.00

-242016

16

14

24.00

20.00

16.00

5

3.00

1

1

V2420

21.00

17.00

-242416

16

14

24.00

24.00

16.00

5

3.00

1

1

V2424

21.00

21.00

-302416

14

14

30.00

24.00

16.00

5

3.00

1

1

V3024

27.00

21.00

-363016

14

14

36.00

30.00

16.00

7

3.00

1

—

V3630

33.00

27.00

-423616

14

14

42.00

36.00

16.00

8

3.00

1

1

V4236

39.00

33.00

-483616

14

14

48.00

36.00

16.00

8

3.00

1

1

V4836

45.00

33.00

-603616

14

14

60.00

36.00

16.00

9

3.00

1

1

V6036

57.00

33.00

-302420

14

14

30.00

24.00

20.00

5

3.00

—

—

V3024

27.00

21.00

-363020

14

14

36.00

30.00

20.00

7

3.00

1

—

V3630

33.00

27.00

-483620

14

14

48.00

36.00

20.00

8

3.00

1

1

V4836

45.00

33.00

-603620

14

14

60.00

36.00

20.00

9

3.00

1

1

V6036

57.00

33.00

-302424

14

14

30.00

24.00

24.00

5

3.00

—

—

V3024

27.00

23.00

Catalog # Prefixes

Gauge Thickness

Box Dimensions
B
C

N4X or N4X6

Box

Door

A

-242008

16

14

24.00

20.00

-242408

16

14

24.00

24.00

-243008

14

14

24.00

-302008

14

14

-302408

14

-303008

Box Stiff. Door Stiff.
Qty
Qty

Panel Catalog #
(optional)

Panel Dimensions
X
Y

11
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

1A–7

Enclosure

15599 Sec.1 12/9/01 10:39 AM Page 12

NEMA Type 4X Victory™ Series Stainless Steel Enclosures

1A–8

These enclosures are designed to provide protection
against dust, dirt, oil and water. They are for use in
petrochemical plants, dairies, breweries, food processing
areas and similar environments where they are subject to
frequent high pressure hosing and generally wet
conditions. They are also designed for use in areas where
severe corrosion problems exist. (Not submersible.)

Construction
Adalet’s AVSS enclosures are made from Type 304 or
Type 316 stainless steel with a #3 - #4 brush finish.
(Replace SS with SS6 in catalog when ordering Type 316
stainless steel). All seams are continuously welded and
ground to a smooth finish. AVSS enclosures have a
formed lip around the door opening to provide complete
and maximum gasket contact and to prevent liquids from
dripping into the enclosure when the door is open.
Each enclosure comes complete with a 1/4-20 grounding
stud, 3/8 collar studs (for mounting optional inner panels).
Each enclosure door is equipped with a neoprene gasket,
1/4-20 grounding stud and slotted quarter-turn latches to
secure the door (optional locking latches are also
available). 180° removable hinge.
Large enclosures come complete with additional panel
mounting studs and maintain a rigid construction through
the use of door and body stiffeners. Print pockets are
furnished upon request and are shipped loose.

Panels
Optional panels are available. Panels are fabricated from
12 ga. cold-rolled steel.

Finish
All enclosures are made from Type 304 or Type 316
stainless steel with a #3 - #4 brush finish. Optional panels
are white.
Shown with optional panel.

Standards
Victory Series Enclosures
Victory series enclosures feature a streamlined design
with a flush door and latches that accommodate any
electrical or electronic application. Adalet has designed
these enclosures to use quarter-turn latches instead of
hold-down clamps (which are often inadequately secured
after servicing, leaving equipment vulnerable to the
elements). Attractive aluminum die-cast hinges are
anodized black.

All AVSS enclosures conform to the National Electrical
Manufacturers Association (NEMA) standard for Type 3
(Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R
(Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and
Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion
Resistant),Type 12 (Industrial Use) and Type 13 (Oiltight
and Dust-tight) enclosures. These enclosures conform to
Joint Industry Council (JIC) standard EGP-1-1967. They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders

Application
Adalet’s AVSS Victory series stainless steel enclosures are
used indoors and outdoors to house such items as
electronic/electrical controls, instrumentation systems,
pneumatic, hydraulic and machine tool controls.

Custom units in special sizes, with punching or with Type
316 stainless steel, can be supplied.
See Victory series panels on page 1C–1, and
accessories on page 1A–10.

12
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 13

1A–9

NEMA Type 4X Victory™ Series Stainless Steel Enclosures

Catalog #
Prefix AVSS
Prefix AVSS6
-121206
-161206
-161606
-201606
-202006
-241606
-242006
-242406
-161208
-161608
-162008
-201608
-202008
-202408
-241608
-242008
-242408
-243008
-302008
-302408
-303008
-362408
-363008
-363608
-202012
-242012
-242412
-302412
-303012
-362412
-363012
-363612
-423612
-483612
-603612
-242416
-363016
-483616
-242420
-302420
-363020

Gauge Thickness†
Box
Door
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
14
16
14
14
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14

16
16
16
16
16
16
16
14
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
16
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14

Box Dimension
A
B
12.00
16.00
16.00
20.00
20.00
24.00
24.00
24.00
16.00
16.00
16.00
20.00
20.00
20.00
24.00
24.00
24.00
24.00
30.00
30.00
30.00
36.00
36.00
36.00
20.00
24.00
24.00
30.00
30.00
36.00
36.00
36.00
42.00
48.00
60.00
24.00
36.00
48.00
24.00
30.00
36.00

12.00
12.00
16.00
16.00
20.00
16.00
20.00
24.00
12.00
16.00
20.00
16.00
20.00
24.00
16.00
20.00
24.00
30.00
20.00
24.00
30.00
24.00
30.00
36.00
20.00
20.00
24.00
24.00
30.00
24.00
30.00
36.00
36.00
36.00
36.00
24.00
30.00
36.00
24.00
24.00
30.00

Latches
D
E

C
6.00
6.00
6.00
6.00
6.00
6.00
6.00
6.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
16.00
16.00
16.00
20.00
20.00
20.00

1
1
1
2
2
2
2
2
1
1
1
2
2
2
2
2
2
2
3
3
3
3
3
3
2
2
2
3
3
3
3
3
3
4
4
2
3
4
2
3
3

† AVSS6 Series: All 14 ga.

ADALET Enclosure Systems • Designing Our Products Around Yours

1
1
1
2
1
1
2
2
2
2
1
2
1

Box

Cover

Stiffener
Qty.

Stiffener
Qty.

1
1
2
2
1
2
2
2
2
2
2
2
2

1
1
1
1
1
1
-

Mounting Centers
M
N
10.50
14.50
14.50
18.50
18.50
22.50
22.50
22.50
14.50
14.50
14.50
18.50
18.50
18.50
22.50
22.50
22.50
22.50
28.50
28.50
28.50
34.50
34.50
34.50
18.50
22.50
22.50
28.50
28.50
34.50
34.50
34.50
40.50
46.50
58.50
22.50
34.50
46.50
22.50
28.50
34.50

10.50
10.50
14.50
14.50
18.50
14.50
18.50
22.50
10.50
10.50
18.50
14.50
18.50
22.50
14.50
18.50
22.50
28.50
18.50
22.50
28.50
28.50
28.50
34.50
18.50
18.50
22.50
22.50
28.50
22.50
28.50
34.50
34.50
34.50
34.50
22.50
28.50
34.50
22.50
22.50
28.50

Panel Cat. #
Optional
V1212
V1612
V1616
V2016
V2020
V2416
V2420
V2424
V1612
V1616
V1620
V2016
V2020
V2024
V2416
V2420
V2424
V2430
V3020
V3024
V3030
V3630
V3630
V3636
V2020
V2420
V2424
V3024
V3030
V3624
V3630
V3636
V4236
V4836
V6036
V2424
V3630
V4836
V2424
V3024
V3630

Panel Dim.
X
Y
9
13
13
17
17
21
21
21
13
13
13
17
17
17
21
21
21
21
27
27
27
33
33
33
17
21
21
27
29
33
33
33
39
45
57
21
33
45
21
27
33

9
9
13
13
17
13
17
21
9
13
17
13
17
21
13
17
21
27
17
21
27
27
27
33
17
17
21
21
27
21
27
33
33
33
33
21
27
33
21
21
27

13
SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 14

Victory™ Series Accessories

1A–10

Wall Mounting Brackets
V-SSWMB •
•
•
•
•

4 stainless steel brackets
Maintain 4, 4X, 12, 13 ratings
Field installable
No punching or drilling required
All hardware included

V-SSWMB

Locks & Latches
Z-2011

Wing knob lock key

Z-2033

Wing knob latch

Z-2034

Wing knob latch

Z-2011

Z-2033

Z-2034

Padlock Kits
PCC

Covers quarter-turn catch to prevent
access (stainless steel)
• Maintain 4, 4X, 12, 13 ratings
• Field installable
• No punching or drilling required

PCC

14
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 15

1A–11

NEMA Type 4X Stainless Steel Double Door Enclosures

subject to frequent high pressure hosing and generally
wet conditions. They are also designed for areas where
severe corrosion problems exist. (Not submersible.)

Construction
Adalet’s N4X-DD-SS enclosures are made from 12 ga.
Type 304 stainless steel with a #4 brush finish. All seams
are continuously welded and ground to a smooth finish.
The N4X-DD-SS enclosure has a folded lip around the door
opening to provide complete and maximum gasket
contact, and to prevent liquids from dripping into the
enclosure when doors are open.
Each enclosure comes complete with 3/8 collar studs (for
mounting optional panels) and two support brackets
welded to the bottom of the enclosure to aid in optional
panel installation. Each enclosure is equipped with 1/4-20
grounding studs, and two 5/8 eye bolts complete with
solid rubber seals and reinforcing support angles welded
to the top of the enclosure for easy handling. The N4XDD-SS enclosures are equipped with wall mounting
brackets and body stiffeners.
Each enclosure door is equipped with a neoprene gasket,
removable print pocket, 1/4-20 grounding studs, stainless
steel door clamping hardware on three sides and
padlocking hasp. Each door rests on a removable center
mullion which also provides for easy panel installation.
Doors are easily removed by pulling the pin on the
continuous stainless steel piano hinge. There are no
knock-outs or holes in the doors or body.

Panels
Optional panels are available. Panels are fabricated from
12 ga. cold-rolled steel.

Finish
All enclosures are made from Type 304 stainless steel
with a #4 brush finish. Panels are finished with a high
gloss white polyester powder coating.

Standards
Shown with optional panel.

Application
Adalet’s N4X-DD-SS double-door enclosures are used
indoors and outdoors to house such items as
electronic/electrical controls, instrumentation systems,
and pneumatic, hydraulic, and machine tool controls.
These enclosures are designed to provide protection
against dust, dirt, oil and water. They are suitable for use
in petrochemical plants, dairies, breweries, food
processing areas and similar environments where they are

All N4X-DD-SS enclosures conform to the National
Electrical Manufacturers Association (NEMA) standard for
Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type
3R (Rainproof and Sleet/Ice Resistant), Type 4 (Watertight
and Dust-tight), Type 4X (Watertight, Dust-tight and
Corrosion Resistant), Type 12 (Industrial Use) and Type 13
(Oiltight and Dust-tight) enclosures. These enclosures
conform to Joint Industry Council (JIC) standard EGP-11967. They are listed by Underwriters Laboratories, Inc.
(UL) and are certified by the Canadian Standards
Association (CSA).

Special Orders
Custom units in special sizes, with punching or with Type
316 stainless steel, can be supplied.
15

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 16

NEMA Type 4X Stainless Steel Double Door Enclosures

1A–12
A

B

5/8 EYEBOLTS

C

3

1 3/8

2

1 1/4

B-4
A-3 1/2
OPENING

2

PADLOCK
PROVISION

A-2 1/2

1/3 A

A-4
Z

A

Z

2

A
PRINT POCKET

SECTION A-A

DOOR CLAMP MAX 18" CENTERS
B/2-2 1/2

B/2-2 1/2

1 1/4

GASKET

PANEL

1 1/16
1 3/4

BRACING
B/2-3 1/2
OPENING

B/2-3 1/2
OPENING

3 1/2

C

1 3/4
7/8

B-4
3/8 COLLAR STUD

2
SECTION Z-Z

1 1/8
B

Enclosure

Panel

Catalog Number

A

Size
B

C

Catalog Number

N4X-DD-SS-604812
N4X-DD-SS-606012
N4X-DD-SS-726012
N4X-DD-SS-727212

60
60
72
72

48
60
60
72

12
12
12
12

D-60P48
D-60P60
D-72P60
D-72P72

Size
56X44
56X56
68X56
68X68

All dimensions in inches

16
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 17

1B–1

NEMA Type 4X JIC Aluminum Enclosures – Continuous Hinge Cover

Application
Adalet's JN4XHA aluminum wall-mounted enclosure can
be used indoors or outdoors to provide protection against
dust, dirt, oil and water for items such as hydraulic or
pneumatic instruments, transformers, and junction wiring.
These lightweight enclosures are suitable for applications
in petrochemical plants, marine areas, sewage plants,
areas containing solvents, and similar environments where
they can be subject to frequent high pressure hosing and
generally wet conditions. They are not for use in areas
where severe corrosion problems exist. (Not submersible.)

Construction
Adalet's JN4XHA enclosures are available in Type 5052H32 aluminum with a brushed finish. The enclosure has
continuously welded seams ground to a smooth finish. It
also comes complete with four 10-32 standoffs (for
mounting optional panels). Grounding studs are provided
on the inside of the box only, and wall mounting back
brackets are mechanically clinched on the top and bottom
outside. The JN4XHA cover is sealed with a neoprene
gasket and is secured to the enclosure with a
mechanically clinched continuous aluminum piano hinge
on one side and stainless steel door clamping hardware
on three sides. There are no knock-outs or holes in the
cover or body.

Panels
Optional panels are available. Panels are fabricated from
14 ga. cold-rolled steel and are powder coated white.

Standards
All JN4XHA enclosures conform to the National Electrical
Manufacturers Association (NEMA) standard for Type 3
(Dust-tight, Raintight and Sleet / Ice Resistant), Type 3R
(Rainproof and Sleet / Ice Resistant), Type 4 (Watertight
and Dust-tight), Type 4X (Watertight, Dust-tight and
Corrosion Resistant), Type 12 (Dust-tight) and Type 13
(Oiltight and Dust-tight) enclosures. They are listed by
Underwriters Laboratories, Inc. (UL) for Canada and the
United States.

Special Orders
Shown with optional panel.

Custom units in special sizes or with punching can be
supplied.

17
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 18

NEMA Type 4X JIC Aluminum Enclosures – Continuous Hinge Cover

1B–2
Catalog
No.

Dimensions
(in)
HxWxD

Material
Thickness
Box / Cover

Weight
(lbs)

Panel
Catalog
No.

Panel Size
(in)
X xY

JN4XHA-060604

6x6x4

0.08 / 0.08

1

1

6.75

4.00

2

06P06

4.88 x 4.88

JN4XHA-080604

8x6x4

0.08 / 0.08

1

1

8.75

4.00

2

08P06

6.88 x 4.88

JN4XHA-100804

10 x 8 x 4

0.08 / 0.08

2

1

10.75

6.00

3

10P08

8.88 x 6.88

JN4XHA-121005

12 x 10 x 5

0.08 / 0.08

2

2

12.75

8.00

5

12P10

10.88 x 8.88

JN4XHA-141206

14 x 12 x 6

0.08 / 0.08

2

2

14.75

10.00

7

14P12

12.88 x 10.88

JN4XHA-161406

16 x 14 x 6

0.08 / 0.08

3

2

16.75

12.00

8

16P14

14.88 x 12.88

Hold Downs
H side W side

Mounting
Dim. (in)
M
N

All dimensions in inches

18
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 19

NEMA Type 4X Aluminum Single Door Enclosures

1B–3

Application
Adalet's N4XA aluminum single door wall-mount
enclosure can be used indoors or outdoors to house items
such as pilot devices, electronic or electrical controls,
instrumentation systems, and hydraulic, pneumatic and
machine tool controls. These enclosures are designed to
protect against dust, dirt, oil and water. They are suitable
for applications in petrochemical plants, marine areas,
sewage plants, areas containing solvents, and similar
environments where they can be subject to frequent high
pressure hosing and generally wet conditions. They are
not for use in areas where severe corrosion problems
exist. (Not submersible.)

Construction
Adalet's N4XA enclosures are available in Type 5052-H32
aluminum with a smooth brushed finish. The enclosure
has continuously welded seams ground to a smooth
finish. Around the door opening it has a folded lip
consisting of multiple 90 degree bends. This provides
complete and maximum gasket contact, and prevents
liquids from dripping into the enclosure when the door is
open. Each enclosure comes complete with 3/8 collar
studs (for mounting optional panels), 1⁄4-20 grounding
studs on inside of box, padlock hasp & staple. The
continuous piano hinge and mounting feet are secured to
the box by mechanical clinching.

Panels
Optional panels are available. Panels are fabricated from
12 ga. cold-rolled steel and are powder coated white.

Standards
All N4XA enclosures conform to the National Electrical
Manufacturers Association (NEMA) standard for Type 3
(Dust-tight, Raintight and Sleet / Ice Resistant), Type 3R
(Rainproof and Sleet / Ice Resistant), Type 4 (Watertight
and Dust-tight), Type 4X (Watertight, Dust-tight and
Corrosion Resistant), Type 12 (Dust-tight) and Type 13
(Oiltight and Dust-tight) enclosures. They are listed by
Underwriters Laboratories, Inc. (UL) for Canada and the
United States.

Special Orders
Custom units in special sizes or with punching can be
supplied.

19
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 20

NEMA Type 4X Aluminum Single Door Enclosures

1B–4
Catalog
No.

Dimensions
(in)
HxWxD

Material
Thickness
Box / Cover

N4XA-161206

16 x 12 x 6

0.08 / 0.08

2

1

17.25

9.50

10

V1612

13.00 x 9.00

N4XA-201606

20 x 16 x 6

0.08 / 0.08

2

1

21.25

10.00

13

V2016

17.00 x 13.00

N4XA-202006

20 x 20 x 6

0.08 / 0.08

2

1

21.25

14.00

16

V2020

17.00 x 17.00

N4XA-242006

24 x 20 x 6

0.08 / 0.08

3

1

25.25

14.00

18

V2420

21.00 x 17.00

N4XA-161608

16 x 16 x 8

0.08 / 0.08

2

1

17.25

10.00

13

V1616

13.00 x 13.00

N4XA-242408

24 x 24 x 8

0.08 / 0.08

3

1

25.25

18.00

23

V2424

21.00 x 21.00

N4XA-302408

30 x 24 x 8

0.08 / 0.08

3

1

31.25

18.00

27

V3024

27.00 x 21.00

N4XA-362408

36 x 24 x 8

0.08 / 0.08

3

1

37.25

18.00

30

V3624

33.00 x 21.00

N4XA-363008

36 x 30 x 8

0.08 / 0.08

3

2

37.25

24.00

37

V3630

33.00 x 27.00

N4XA-483608

48 x 36 x 8

0.08 / 0.08

4

2

49.25

30.00

52

V4836

45.00 x 33.00

N4XA-201610

20 x 16 x 10

0.08 / 0.08

2

1

21.25

10.00

16

V2016

17.00 x 13.00

N4XA-242010

24 x 20 x 10

0.08 / 0.08

3

1

25.25

14.00

21

V2420

21.00 x 17.00

N4XA-302412

30 x 24 x 12

0.08 / 0.08

3

1

31.25

18.00

32

V3024

27.00 x 21.00

N4XA-363012

36 x 30 x 12

0.08 / 0.08

3

2

37.25

24.00

43

V3630

33.00 x 27.00

Hold Downs
H side W side

Mounting
Dim. (in)
M
N

Weight
(lbs)

Panel
Catalog
No.

Panel Size
(in)
X xY

All dimensions in inches

20
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 21

1C–1

Accessory Inner Panels

Panels for N4X Single Door and
Victory Series Enclosures
12 Ga. Steel with White Polyester Powder
Coat Finish
Catalog
Number

Panels for N4X JIC Enclosures
14 Ga. Steel with White Polyester Powder
Coat Finish
Catalog
Number

For
Enclosure

Panel Size

06P04
06P06
08P06
08P08
10P08

6x4
6x6
8x6
8x8
10 x 8

4
4
6
6
8

10P10
12P10
12P12
14P08

10 x 10
12 x 10
12 x 12
14 x 8

8 7/8
10 7/8
10 7/8
12 7/8

8 7/8
8 7/8
10 7/8
6 7/8

14P12
16P14

14 x 12
16 x 14

12 7/8
14 7/8

10 7/8
12 7/8

H

For
Enclosure

Panel Size
H

W

V-1212
V-1612
V-1616
V-2016

12
16
16
20
16

x
x
x
x
x

12
12
16
16
20

9
13
13
17

9
9
13
13

V-2020
V-2412
V-2416
V-2420

20
24
24
24
20

x
x
x
x
x

20
12
16
20
24

17
21
21
21

17
9
13
17

V-2424
V-3020
V-3024

x
x
x
x
x

24
20
24
30
30

21
27
27

21
17
21

V-3030

24
30
30
24
30

27

27

V-3624
V-3630
V-3636

36 x 24
36 x 30
36 x 36

33
33
33

21
27
33

V-4230
V-4236
V-4836

42 x 30
42 x 36
48 x 36

39
39
45

27
33
33

V-6036

60 x 36

57

33
All dimensions in inches

W

7/8
7/8
7/8
7/8
7/8

2
4
4
6
6

7/8
7/8
7/8
7/8
7/8

Special Orders
Custom sizes and panels fabricated from
stainless steel and aluminum are available.
Consult factory for more information.

All dimensions in inches

21
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 22

Floor Stand Kit

1C–2

Application
Kits, consisting of two mounting feet, are designed for
easy installation on most wall-mounted enclosures.
Mounting feet enable enclosures to be floor mounted, and
at the same time raise the enclosure 12" from the ground
to clear flood levels or for easy working access.

Construction
Mounting feet are made from Type 304 stainless steel
and are pre-punched for ease of mounting to both floor
and enclosure. Each kit comes complete with necessary
hardware for mounting.

Catalog Number
12MF-12-SS

Height

Enclosure
Depth

12

12
All dimensions in inches

Special Orders
Custom units made with special heights, depths or materials
can be supplied.

22
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 23

1C–3

Latches, Locks and Handles

Vault Type Locking Handle
7" long cadmium plated padlocking handle
Cat. No. Z-1010

No. Z-1010

Automotive Locking Handle
4 1/2" chrome plated key locking handle
Cat. No. Z-1011-L (Clockwise Turn)
Cat. No. Z-1011-R (Counterclockwise Turn)

No. Z-1011

Wing Knob Key Lock
Quarter-turn lock
Cat. No. Z-2011

No. Z-2011

Wing Knob Latch
Quarter-turn lock
Cat. No. Z-2033

No. Z-2033

Wing Knob Latch
Quarter-turn lock
Cat. No. Z-2034

No. Z-2034

23
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.1 12/9/01 10:39 AM Page 24

Other Accessories

1C–4

Gasket
For Type 4X enclosures – 80' per roll
Closed-cell neoprene sponge with rubber-based
adhesive (.25" thick x 1" wide)
Cat. No. M1423

24
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 25

NEMA Type 4X Pushbutton Fiberglass Enclosures

Application
The pushbutton fiberglass enclosure can be used indoors
or outdoors to provide protection against dust, dirt, oil and
water for items such as pushbuttons, pilot lights and
switches. Designed for installation of standard 30mm
operators.

2A–1

Construction
The pushbutton enclosures are constructed of
compression molded, fiberglass reinforced polyester with
covers flush with enclosures sides. Cover gasket is a
continuous urethane material. Cover screws are recessed
and made of stainless steel. A metal grounding strap is
supplied. Interior mounting wells are gasketed and sealed
from the inside. There are no external mounting feet with
this enclosure. Machine tool gray color.

Panels
There are no panel provisions with these enclosures.

Standards
All pushbutton fiberglass enclosures conform to the
National Electrical Manufacturers Association (NEMA)
standard for Type 3 (Dust-tight, Raintight and Sleet/Ice
Resistant), Type 4X (Watertight, Dust-tight and Corrosion
Resistant) and Type 12 (Dust-tight). They are listed by
Underwriters Laboratories, Inc. (UL) for Canada and the
United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

25
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 26

NEMA Type 4X Pushbutton Fiberglass Enclosures

C

A

M

2.25

H

2A–2

2.25

N

SEE DETAIL A

W

Ø.22
.22 (4)PLACES

.67

.19

.67

B

D

Ø1.21
1.21

DETAIL A

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-1PB

6.63 x 3.81 x 3.89

6 x 3.19 x 3.63

4.88

N4X-FG-2PB

6.63 x 3.81 x 3.89

6 x 3.19 x 3.63

N4X-FG-3PB

8.88 x 3.81 x 3.89

8.26 x 3.19 x 3.63

Mounting
Dim. (in)
M
N

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

2.94

2

No Panel

NA

4.88

2.94

2

No Panel

NA

7.13

2.94

2

No Panel

NA

All dimensions in inches

26
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 27

NEMA Type 4X Flush Cover Fiberglass Enclosures

Application
The flush cover fiberglass enclosure can be used indoors
or outdoors to house items such as standard size
pushbuttons, pilot lights and switches. These enclosures
are designed to protect against dust, dirt, oil and water.

Construction

2A–3

The flush cover enclosures are constructed of
compression molded, fiberglass reinforced polyester. The
covers are flush with sides of enclosure. Cover gasket is a
continuous urethane material. Recessed cover screws are
made of stainless steel. Interior mounting wells are
gasketed and sealed from the inside. There are no
external mounting feet with this enclosure. Machine tool
gray color.

Panels
There are no panel provisions with these enclosures.

Standards
All flush cover fiberglass enclosures conform to the
National Electrical Manufacturers Association (NEMA)
standard for Type 3 (Dust-tight, Raintight and Sleet/Ice
Resistant), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged
Submersion in Water). They are listed by Underwriters
Laboratories, Inc. (UL) for Canada and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

27
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 28

NEMA Type 4X Flush Cover Fiberglass Enclosures

C

H

M

2A–4

A

N

W
Ø.22 (4)PLACES

D

B

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-030302

3.72 x 3.63 x 2.95

3.13 x 3.03 x 2.7

2.31

N4X-FG-050302

5.97 x 3.63 x 3.14

5.38 x 3.03 x 2.87

N4X-FG-060404

6.63 x 3.81 x 3.89

N4X-FG-080404
N4X-FG-110404

Mounting
Dim. (in)
M
N

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

2.75

1

No Panel

NA

4.56

2.75

1

No Panel

NA

6 x 3.19 x 3.63

4.88

2.94

2

No Panel

NA

8.88 x 3.81 x 3.89

8.26 x 3.19 x 3.63

7.13

2.94

2

No Panel

NA

11.13 x 3.81 x 3.89

10.51 x 3.19 x 3.63

9.37

2.94

2

No Panel

NA

All dimensions in inches

28
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 29

NEMA Type 4X Small Screw Cover Fiberglass Enclosures

Application
The screw cover junction fiberglass enclosure can be
used indoors or outdoors to house items such as standard
size pushbuttons, pilot lights and switches. These
enclosures are designed to protect against dust, dirt, oil
and water.

2A–5

Construction
The screw cover junction enclosures are constructed of
compression molded, fiberglass reinforced polyester. The
covers are flush with sides of enclosure. The captive
cover screws are made of stainless steel. The cover
gasket is a continuous urethane material. Interior panel
mounting inserts are molded to enclosure. There are no
external mounting feet with this enclosure. Machine tool
gray color.

Panels
Panels are not available with these enclosures.

Standards
All small screw cover junction fiberglass enclosures
conform to the National Electrical Manufacturers
Association (NEMA) standard for Type 3 (Dust-tight,
Raintight and Sleet/Ice Resistant), Type 4X (Watertight,
Dust-tight and Corrosion Resistant), Type 12 (Dust-tight)
and Type 6P (Prolonged Submersion in Water). They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

29
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 30

NEMA Type 4X Small Screw Cover Fiberglass Enclosures

C

N

A

H

M

2A–6

W

Ø.22 (4) PLACES

D

B

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-070603

7.63 x 6.63 x 3.19

6.9 x 5.9 x 2.88

5.37

N4X-FG-090603

9.87 x 6.63 x 3.19

9.15 x 5.9 x 2.88

7.62

Mounting
Dim. (in)
M
N

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

5.63

2

No Panel

NA

5.63

2

No Panel

NA

All dimensions in inches

30
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 31

NEMA Type 4X Screw Cover Fiberglass Enclosures

Application
The screw cover fiberglass enclosure can be used indoors
or outdoors to provide protection against dust, dirt, oil and
water. It is designed for use as a terminal wiring box,
instrumentation housing or electrical control enclosure.

Construction

2A–7

The screw cover enclosures are constructed of
compression molded, fiberglass reinforced polyester with
stainless steel captive cover screws. The cover gasket is a
continuous urethane material. A stainless steel retaining
chain is attached to the cover and enclosure. Panel
mounting inserts are molded to interior of enclosure.
External mounting feet are also molded to enclosure.
Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.080”
aluminum.

Standards
All screw cover fiberglass enclosures conform to the
National Electrical Manufacturers Association (NEMA)
standard for Type 3 (Dust-tight, Raintight and Sleet/Ice
Resistant), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged
Submersion in Water). They are listed by Underwriters
Laboratories, Inc. (UL) for Canada and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

31
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 32

NEMA Type 4X Screw Cover Fiberglass Enclosures

MOUNTING
MOUNTINGPANEL
PANEL
(ORDERSEPARATELY)
SEPARATELY
(ORDER
0.31
PLACES
ÿ.31
.31 (4) PLACES

N

H

A

2A–8

M

C

W

D

P

B

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

M

N4X-FG-060604SC

7.50 x 7.50 x 4.75

5.72 x 5.72 x 4.45

6.75

4.00

N4X-FG-080604SC

9.62 x 7.50 x 4.74

7.73 x 5.74 x 4.45

8.88

N4X-FG-100804SC

11.62 x 9.41 x 4.25

9.73 x 7.73 x 3.98

N4X-FG-121005SC

13.56 x 11.43 x 5.21

N4X-FG-141206SC

15.50 x 13.50 x 6.25

Mounting
Dim. (in)
N
P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

4.00

3

BP66A

4.88 x 4.88

4.00

4.00

4

BP86A

6.88 x 4.88

10.75

6.00

3.50

5

BP108A

8.88 x 6.88

11.79 x 9.8 x 4.94

12.75

8.00

4.50

7

BP1210A

10.88 x 8.88

13.53 x 11.55 x 5.94

14.62

10.00

5.37

9

BP1412A

12.88 x 10.90

All dimensions in inches

32
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 33

NEMA Type 4X Hinged Screw Cover Fiberglass Enclosures

Application
The hinged screw cover fiberglass enclosure can be used
indoors or outdoors to provide protection against dust,
dirt, oil and water. It is designed for use as a terminal
wiring box, instrumentation housing or electrical control
enclosure where a hinged cover is desired.

2A–9

Construction
The hinged screw cover enclosures are constructed of
compression molded, fiberglass reinforced polyester.
Enclosure includes a stainless steel continuous hinge with
stainless steel captive cover screws. The cover gasket is a
continuous urethane material. Panel mounting inserts are
molded to interior of enclosure. External mounting feet
are also molded to enclosure. Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.080”
aluminum.

Standards
All hinged screw cover fiberglass enclosures conform to
the National Electrical Manufacturers Association (NEMA)
standard for Type 3 (Dust-tight, Raintight and Sleet/Ice
Resistant), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged
Submersion in Water). They are listed by Underwriters
Laboratories, Inc. (UL) for Canada and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

33
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 34

NEMA Type 4X Hinged Screw Cover Fiberglass Enclosures

MOUNTING PANEL
(ORDER SEPARATELY)
Ø.31 (4) PLACES

N

H

A

2A–10

M

C

W

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-060604CHSC

7.50 x 7.50 x 4.75

5.72 x 5.72 x 4.45

N4X-FG-080604CHSC

9.62 x 7.50 x 4.74

N4X-FG-100804CHSC

D

P

B

M

Mounting
Dim. (in)
N

P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

6.75

4.00

4.00

3

BP66A

4.88 x 4.88

7.73 x 5.74 x 4.45

8.88

4.00

4.00

4

BP86A

6.88 x 4.88

11.62 x 9.41 x 4.25

9.73 x 7.73 x 3.98

10.75

6.00

3.50

5

BP108A

8.88 x 6.88

N4X-FG-121005CHSC

13.56 x 11.43 x 5.21

11.79 x 9.80 x 4.94

12.75

8.00

4.50

7

BP1210A

10.88 x 8.88

N4X-FG-141206CHSC

15.50 x 13.50 x 6.25

13.53 x 11.55 x 5.94

14.62

10.00

5.37

9

BP1412A

12.88 x 10.90

N4X-FG-161406CHSC

17.53 x 15.46 x 6.23

15.63 x 13.60 x 5.94

16.75

12.00

5.36

12

BP1614A

14.88 x 12.90

N4X-FG-181608CHSC

19.62 x 17.61 x 8.82

17.69 x 15.69 x 8.45

18.88

12.00

7.99

19

BP1816A

16.88 x 14.90

All dimensions in inches

34
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 35

NEMA Type 4X Quick Release Latch Fiberglass Enclosures – Flat Cover

Application
The quick release latch fiberglass enclosure can be used
indoors or outdoors to provide protection against dust,
dirt, oil and water. It is designed for use as a terminal
wiring box, instrumentation housing or electrical control
enclosure where a hinged cover is desired.

2A–11

Construction
The quick release latch enclosures are constructed of
compression molded, fiberglass reinforced polyester.
Enclosure includes a stainless steel continuous hinge and
stainless steel quick release latches with padlock hasps.
The cover gasket is a continuous urethane material. Panel
mounting inserts are molded to interior of enclosure.
External mounting feet are also molded to enclosure.
Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.080”
or 0.090” aluminum.

Standards
All flat cover quick release latch fiberglass enclosures
conform to the National Electrical Manufacturers
Association (NEMA) standard for Type 3 (Dust-tight,
Raintight and Sleet/Ice Resistant), Type 4X (Watertight,
Dust-tight and Corrosion Resistant), Type 12 (Dust-tight)
and Type 6P (Prolonged Submersion in Water). They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

35
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 36

NEMA Type 4X Quick Release Latch Fiberglass Enclosures – Flat Cover

MOUNTING PANEL
(ORDER SEPARATELY)
Ø.31 (4) PLACES

N

H

A

2A–12

M

C

W

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-060604CHQR

7.50 x 7.50 x 4.75

5.72 x 5.72 x 4.45

N4X-FG-080604CHQR

9.62 x 7.50 x 4.74

N4X-FG-100804CHQR

D

P

B

M

Mounting
Dim. (in)
N

P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

6.75

4.00

4.00

3

BP66A

4.88 x 4.88

7.73 x 5.74 x 4.45

8.88

4.00

4.00

4

BP86A

6.88 x 4.88

11.62 x 9.41 x 4.25

9.73 x 7.73 x 3.98

10.75

6.00

3.50

5

BP108A

8.88 x 6.88

N4X-FG-121005CHQR

13.56 x 11.43 x 5.21

11.79 x 9.80 x 4.94

12.75

8.00

4.50

7

BP1210A

10.88 x 8.88

N4X-FG-141206CHQR

15.50 x 13.50 x 6.25

13.53 x 11.55 x 5.94

14.62

10.00

5.37

9

BP1412A

12.88 x 10.90

N4X-FG-161406CHQR

17.53 x 15.46 x 6.73

15.63 x 13.60 x 5.94

16.75

12.00

5.36

12

BP1614A

14.88 x 12.90

N4X-FG-181608CHQR

19.62 x 17.61 x 8.82

17.69 x 15.69 x 8.45

18.88

12.00

7.99

19

BP1816A

16.88 x 14.90

N4X-FG-201608CHQR

22.00 x 17.68 x 8.83

19.72 x 15.72 x 8.45

21.25

10.00

8.00

21

BP2016A

17.00 x 13.00

All dimensions in inches

36
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 37

NEMA Type 4X Twist Latch Fiberglass Enclosures – Flat Cover

Application
The twist latch fiberglass enclosure can be used indoors
or outdoors to provide protection against dust, dirt, oil and
water. It is designed for use as a terminal wiring box,
instrumentation housing or electrical control enclosure
where a hinged cover is desired.

2A–13

Construction
The twist latch enclosures are constructed of
compression molded, fiberglass reinforced polyester.
Enclosure includes a stainless steel continuous hinge and
stainless steel twist latches. The cover gasket is a
continuous urethane material. Panel mounting inserts are
molded to interior of enclosure. External mounting feet
are also molded to enclosure. Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.080”
or 0.090” aluminum.

Standards
All flat cover twist latch fiberglass enclosures conform to
the National Electrical Manufacturers Association (NEMA)
standard for Type 3 (Dust-tight, Raintight and Sleet/Ice
Resistant), Type 4X (Watertight, Dust-tight and Corrosion
Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged
Submersion in Water). They are listed by Underwriters
Laboratories, Inc. (UL) for Canada and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

37
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 38

NEMA Type 4X Twist Latch Fiberglass Enclosures – Flat Cover

MOUNTING PANEL
(ORDER SEPARATELY)
Ø.31 (4) PLACES

N

C

A

H

M

2A–14
W

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-060604CHTL

7.50 x 7.50 x 4.75

5.72 x 5.72 x 4.45

N4X-FG-080604CHTL

9.62 x 7.50 x 4.74

N4X-FG-100804CHTL

D

P

B

M

Mounting
Dim. (in)
N

P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

6.75

4.00

4.00

3

BP66A

4.88 x 4.88

7.73 x 5.74 x 4.45

8.88

4.00

4.00

4

BP86A

6.88 x 4.88

11.62 x 9.41 x 4.25

9.73 x 7.73 x 3.98

10.75

6.00

3.50

5

BP108A

8.88 x 6.88

N4X-FG-121005CHTL

13.56 x 11.43 x 5.21

11.79 x 9.80 x 4.94

12.75

8.00

4.50

7

BP1210A

10.88 x 8.88

N4X-FG-141206CHTL

15.50 x 13.50 x 6.25

13.53 x 11.55 x 5.94

14.62

10.00

5.37

9

BP1412A

12.88 x 10.90

N4X-FG-161406CHTL

17.53 x 15.46 x 6.23

15.63 x 13.60 x 5.94

16.75

12.00

5.36

12

BP1614A

14.88 x 12.90

N4X-FG-181608CHTL

19.62 x 17.61 x 8.82

17.69 x 15.69 x 8.45

18.88

12.00

7.99

19

BP1816A

16.88 x 14.99

N4X-FG-201608CHTL

22.00 x 17.68 x 8.83

19.72 x 15.72 x 8.45

21.25

10.00

8.00

21

BP2016A

17.00 x 13.00

All dimensions in inches

38
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 39

NEMA Type 4X Raised Cover Fiberglass Enclosures – Quick Release Latch

Application

2A–15

The raised cover quick release latch fiberglass enclosure
can be used indoors or outdoors to provide protection
against dust, dirt, oil and water. It is designed for use as a
terminal wiring box, instrumentation housing or electrical
control enclosure where a hinged cover is desired. It is
also designed for use when components require
additional depth.

Construction
The raised cover quick release latch enclosures are
constructed of compression molded, fiberglass reinforced
polyester. Enclosure includes a stainless steel continuous
hinge and stainless steel quick release latches with
padlock hasps. The cover gasket is a continuous urethane
material. Panel mounting inserts are molded to interior of
enclosure. External mounting feet are also molded to
enclosure. Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.080”
or 0.090” aluminum.

Standards
All raised cover quick release latch fiberglass enclosures
conform to the National Electrical Manufacturers
Association (NEMA) standard for Type 3 (Dust-tight,
Raintight and Sleet/Ice Resistant), Type 4X (Watertight,
Dust-tight and Corrosion Resistant), Type 12 (Dust-tight)
and Type 6P (Prolonged Submersion in Water). They are
listed by Underwriters Laboratories, Inc. (UL) for Canada
and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

39
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 40

NEMA Type 4X Raised Cover Fiberglass Enclosures – Quick Release Latch

MOUNTING PANEL
(ORDER SEPARATELY)

Ø.31 (4) PLACES

C

H

M

2A–16

A

N

W

D

P

B

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-080606RCHQR

9.62 x 7.46 x 6.22

7.73 x 5.74 x 5.95

N4X-FG-100806RCHQR

11.62 x 9.37 x 6.61

N4X-FG-121006RCHQR

M

Mounting
Dim. (in)
N

P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

8.88

4.00

5.49

4

BP86A

6.88 x 4.88

9.73 x 7.73 x 6.36

10.75

6.00

5.91

5

BP108A

8.88 x 6.88

13.56 x 11.43 x 6.61

11.79 x 9.80 x 6.32

12.75

8.00

5.87

7

BP1210A

10.88 x 8.88

N4X-FG-141207RCHQR

15.50 x 13.38 x 7.69

13.53 x 11.55 x 7.45

14.62

10.00

6.87

9

BP1412A

12.88 x 10.90

N4X-FG-161407RCHQR

17.53 x 15.43 x 7.71

15.63 x 13.60 x 7.45

16.75

12.00

6.87

12

BP1614A

14.88 x 12.90

N4X-FG-181610RCHQR

19.62 x 17.48 x 10.62

17.69 x 15.69 x 10.31

18.88

12.00

9.86

19

BP1816A

16.88 x 14.90

N4X-FG-201610RCHQR

22.00 x 17.56 x 10.64

19.72 x 15.72 x 10.33

21.25

10.00

9.87

21

BP2016A

17.00 x 13.00

All dimensions in inches

40
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 41

NEMA Type 4X Raised Cover Fiberglass Enclosures – Twist Latch

Application

2A–17

The raised cover twist latch fiberglass enclosure can be
used indoors or outdoors to provide protection against
dust, dirt, oil and water. It is designed for use as a
terminal wiring box, instrumentation housing or electrical
control enclosure where a hinged cover is desired. It is
also designed for use when components require
additional depth.

Construction
The raised cover twist latch enclosures are constructed of
compression molded, fiberglass reinforced polyester.
Enclosure includes a stainless steel continuous hinge and
stainless steel twist latches. The cover gasket is a
continuous urethane material. Panel mounting inserts are
molded to interior of enclosure. External mounting feet
are also molded to enclosure. Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.080”
or 0.090” aluminum.

Standards
All raised cover twist latch fiberglass enclosures conform
to the National Electrical Manufacturers Association
(NEMA) standard for Type 3 (Dust-tight, Raintight and
Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and
Corrosion Resistant), Type 12 (Dust-tight) and Type 6P
(Prolonged Submersion in Water). They are listed by
Underwriters Laboratories, Inc. (UL) for Canada and the
United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

41
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 42

NEMA Type 4X Raised Cover Fiberglass Enclosures – Twist Latch

MOUNTING PANEL
(ORDER SEPARATELY)

Ø.31 (4) PLACES

N
C

A

H

M

2A–18

W

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-100806RCHTL

11.62 x 9.37 x 6.61

9.73 x 7.73 x 6.36

N4X-FG-121006RCHTL

13.56 x 11.43 x 6.61

N4X-FG-141207RCHTL

D

P

B

M

Mounting
Dim. (in)
N

P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

10.75

6.00

5.91

5

BP108A

8.88 x 6.88

11.79 x 9.80 x 6.32

12.75

8.00

5.87

7

BP1210A

10.88 x 8.88

15.50 x 13.38 x 7.69

13.53 x 11.55 x 7.45

14.62

10.00

6.87

9

BP1412A

12.88 x 10.90

N4X-FG-161407RCHTL

17.53 x 15.43 x 7.71

15.63 x 13.60 x 7.45

16.75

12.00

6.87

12

BP1614A

14.88 x 12.90

N4X-FG-181610RCHTL

19.62 x 17.48 x 10.62

17.69 x 15.69 x 10.31

18.88

12.00

9.86

19

BP1816A

16.88 x 14.90

All dimensions in inches

42
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 43

NEMA Type 4X Large Control Fiberglass Enclosures

Application
The large control fiberglass enclosure can be used indoors
or outdoors to provide protection against dust, dirt, oil and
water. It is designed to house items such as electronic or
electrical controls, instrumentation systems and
mechanical controls.

2A–19

Construction
The large control enclosures are constructed of
compression molded, fiberglass reinforced polyester.
Enclosure includes a stainless steel continuous hinge and
stainless steel twist latches. A padlock hasp is also
included. The cover gasket is a continuous urethane
material. Panel mounting inserts are molded to interior of
enclosure. External mounting feet are also molded to
enclosure. Machine tool gray color.

Panels
Optional panels are available. Panels fabricated of 0.090”
or 0.130” aluminum.

Standards
All large control enclosures conform to the National
Electrical Manufacturers Association (NEMA) standard for
Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type
4X (Watertight, Dust-tight and Corrosion Resistant) and
Type 12 (Dust-tight). They are listed by Underwriters
Laboratories, Inc. (UL) for Canada and the United States.

Special Orders
Custom units with holes punched and operators installed
can be supplied.

43
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.2 12/9/01 10:41 AM Page 44

NEMA Type 4X Large Control Fiberglass Enclosures

N

A

M

2A–20

H

C

Ø.50 (4) PLACES

P
D

B
W

Catalog
No.

Overall
Dimensions
(in)
AxBxC

Inside
Dimensions
(in)
HxWxD

N4X-FG-201606CH

22.75 x 16.87 x 7.77

19.70 x 16.04 x 7.24

N4X-FG-201608CH

22.75 x 16.87 x 9.77

N4X-FG-201612CH

M

Mounting
Dim. (in)
N

P

Weight
(lbs)

Panel
Catalog
No.

Panel
Size
(in)

21.50

10.12

6.26

17

BPN2016A

17.00 x 13.00

19.70 x 16.04 x 9.24

21.50

10.12

8.26

22

BPN2016A

17.00 x 13.00

22.75 x 16.87 x 13.77

19.70 x 16.04 x 13.24

21.50

10.12

12.26

24

BPN2016A

17.00 x 13.00

N4X-FG-242008CH

27.00 x 21.24 x 9.90

24.05 x 20.39 x 9.25

25.75

14.00

8.25

32

BP2420A

21.00 x 17.00

N4X-FG-242410CH

27.00 x 25.24 x 11.90

24.05 x 24.39 x 11.25

25.75

17.87

10.25

42

BP2424A

21.00 x 21.00

N4X-FG-302410CH

33.41 x 26.32 x 11.95

30.46 x 25.47 x 11.27

32.25

18.50

10.27

50

BP3024A

27.00 x 21.00

N4X-FG-302412CH

33.41 x 26.32 x 13.79

30.46 x 25.47 x 13.10

32.25

18.50

12.10

54

BP3024A

27.00 x 21.00

N4X-FG-363010CH

39.31 x 32.50 x 12.05

36.31 x 31.69 x 11.36

38.13

23.88

10.36

78

BP3630A

33.00 x 27.00

N4X-FG-363012CH

39.31 x 32.50 x 14.05

36.31 x 31.69 x 13.36

38.13

23.88

12.36

81

BP3630A

33.00 x 27.00

N4X-FG-483616CH

51.29 x 36.62 x 17.93

48.33 x 36.22 x 17.25

50.12

29.25

16.25

108

BP4836A

45.00 x 33.00

All dimensions in inches

44
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 45

Adalet Increased Safety Enclosures
Increased Safety ‘e’
• Terminal Enclosures (TN, TSC & TFG Series)
• High Voltage Junction Boxes (HV Series)
• Control Panel Assemblies (CN Series)
• Intrinsically Safe Terminal Enclosures (TSC & TFG Series)

Increased Safety/Flameproof ‘ed’
• Control Panel Assemblies (CN Series)

TN4 Series: Single Door Clamped Terminal Enclosures.
14-gauge materials: TN4 steel powder coated; TN4X
stainless steel 304; TN4X6 stainless steel 316L.
TN4 Expanded Series: Single Door Clamped
Terminal Enclosures.

3A–1

TSC Series: Screw Cover Terminal Enclosures.
14-gauge materials: TSC4 steel powder coated;
TSC4X stainless steel 304; TSC4X6 stainless steel 316L.
CN4 Series: Control Panel Enclosure. 14-gauge
materials: CN4 steel powder coated; CN4X stainless
steel 304; CN4X6 stainless steel 316L.
TFG Series: Fiberglass Terminal Enclosures
HV Series: High Voltage Junction Boxes. 14-gauge
materials: HV4 steel powder coated; HV4X stainless
steel 304; HV4X6 stainless steel 316L.

45
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 46

Adalet Increased Safety Enclosures
Increased Safety Enclosures
These enclosures provide an alternative to flameproof
enclosures and are commonly made from sheet steel,
fiberglass, and die cast aluminum. They are intended
to house electrical equipment that will not generate an
arc or spark during normal operation. Additional design
measures are taken to prevent the possibility of
excessive heat, the ingress of water or dust, and the
resistance to impact, thus preventing any explosions
from occurring.

• Temperatures: of parts of equipment must
be limited so as not to exceed values which
would affect the thermal stability of the material
and the T-Class relating to the ignition of
explosive atmospheres.

Areas of Use
Zone Classified Areas – U.S., Canada, Europe
Zones 1 and 2

3A–2

Principle

ATEX – EU Directive 94/9/EC – Europe

Intended for product in which arcs and sparks do not
occur in normal service not under fault conditions and
in which surface temperatures are controlled below
incendive values. Increased Safety is achieved by
enhancing insulation values and creepage and
clearance distances above those required for normal
service, thus providing a safety factor against
accidental breakdown.
Increased Safety must not be confused with
Intrinsically Safe; they are two completely different
approaches. Intrinsic Safety requires that the electrical
components within an enclosure have very low levels
of electrical energy, either stored or circulating.
Typically, allowable currents will be in the tens of
milliamperes and voltage will be less than 100 volts, so
they will be insufficient to ignite a surrounding
explosive atmosphere even under fault conditions.

Equipment Groups II
Equipment Category 2GD

Applicable Standards
Europe: EN50014, EN50019
U.S.: UL2279 pt 7
Canada: CSA-E79-0, CSA-E79-7
International: IEC 60079-0, IEC 60079-7

Typical Testing for Increased
Safety Apparatus
• Thermal conditioning test

Key Design Features
• Enclosure: must be constructed to withstand
mechanical impact and provide a specified degree of
ingress protection (IP rating). A minimum IP54 rating
is required for Increased Safety enclosures.

• Mechanical strength
• Temperature rise
• Ingress Protection (IP Rating)
• Electrical Strength
• Thermal Stability of Insulating Materials

• Terminals for external connections: must be
generously dimensioned for the intended connection
and ensure that conductors are securely fastened.
• Internal connections: must not be subject to
undue mechanical stress and shall be made using
specified methods.
• Clearances: between bare conductive parts must
not be less than the values specified according to
the rated voltage.
• Creepage distances: must not be less than the
values specified according to the rated voltage and
the Comparative Tracking Index (CTI) of the
insulating material.

46
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 47

Hazardous Location Marking
National Electrical Code Article 505

Note 1: Products approved for use in areas classified under
Article 505 could only be used in this area. Products
approved for use in areas classified under Article 500 are
allowed to be installed in Article 505 areas, except Zone 0.

Article 505 was first introduced in the 1996 National Electrical
Code. This new Article offered an alternative to the
classification of hazardous locations based on the standards for
area classification by the International Electrotechnical
Commission (IEC). With the introduction of this new Article,
engineers could now classify hazardous locations using either
Article 500 or Article 505.

Note 2: The IEC Classification scheme also addresses
underground mines. Article 505 does not address this area
classification. All mines in the United States fall under the
jurisdiction of the Mine Safety and Health Administration
(MSHA).

In 1999, further revision to this Article continued to bring it
closer to the IEC 79 series. The 1999 changes introduced:
1. the eight different Protection Methods used by IEC,
2. the inclusion of metric threaded holes, and
3. special precautions involving area classification, dual
classification, and the reclassification of division classified
areas.

Compliance to American
(United States) Standards

Area Classification

3A–3

Equipment Marking
Ambient Temperature Range in Service
(other than –20°C to +40°C)

Class I, Zone 1, AEx ed IIC T5 Tamb -40°C to +50°C IP66
Zone 0 Continuous Hazard
Zone 1 Intermittent Hazard
Zone 2 Hazard Under
Abnormal Conditions

For use in
Explosive
Atmosphere

Temperature Classification

Protection Method
(main concept appears first)
m Encapsulation (Zone 1)

T class

Max Surface Temp

T1

≤450°C

T2

≤300°C

T3

≤ 200°C

T4

≤135°C

T5

≤ 100°C

T6

≤ 85°C

d Flameproof (Zone 1)
e Increased Safety (Zone 1)

Gas Grouping

Ingress Protection

i* Intrinsically Safe (Zone 0/1)

I Methane (firedamp)

IP0x No Protection

IPx0 No Protection

IP1x Objects >50mm

IPx1 Vertically dripping water

o Oil Immersion (Zone 1)
p Pressurized (Zone 1)

(Mining Only)
IIA Propane

IP2x Objects >12mm

IPx2 75° to 90° dripping water

q Powder Filling (Zone 1)

IIB Ethylene

IP3x Objects >2.5mm

IPx3 Sprayed water

n* Non-Sparking (Zone 2)

IIC Acetylene/Hydrogen

IP4x Objects >1mm

IPx4 Splashed water

IIB+H2 Hydrogen

IP5x Dust protected

IPx5 Water jets

II All Gases

IP6x Dust-tight

IPx6 Heavy seas

*denotes additional sub-categories

IPx7 Effects of immersion
IPx8 Indefinite immersion

47
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 48

Hazardous Location Marking
CENELEC

The Conformity Mark

CENELEC is the European Committee for Electrotechnical
Standardization. It was established in 1973 as a non-profit
organization under Belgium Law.

Under the Explosive Atmospheres and
Gassy Mines Directive (79/117/EEC), the
“Epsilion x” symbol indicates conformity
with the CENELEC requirements. This
symbol is only allowed to be applied to
products which are considered to be final assemblies. Not
empty enclosures or component parts.

The European Commission under Directive 83/189/EEC has
officially recognized it as the European Standards Organization
in its field.

Each member country typically has at least one recognized test
agency or notified body. These members have been working
together in the interest of European harmonization since the
late fifties, developing alongside the European Economic
Community. CENELEC works with 35,000 technical experts
from 19 countries to publish standards for the European
market.

3A–4

Equipment Marking
Ambient Temperature Range in Service
(other than –20°C to +40°C)

Compliance to European
Harmonized Standard

EEx ed IIC T5 Tamb -40°C to +50°C IP66
For use in Explosive
Atmosphere

Temperature Classification

Protection Method
(main concept appears first)
m Encapsulation (Zone 1)

T class

Max Surface Temp

T1

≤450°C

T2

≤300°C

T3

≤ 200°C

T4

≤135°C

T5

≤ 100°C

T6

≤ 85°C

d Flameproof (Zone 1)
e Increased Safety (Zone 1)

Gas Grouping

Ingress Protection

i* Intrinsically Safe (Zone 0/1)

I Methane (firedamp)

IP0x No Protection

IPx0 No Protection

IP1x Objects >50mm

IPx1 Vertically dripping water
IPx2 75° to 90° dripping water

o Oil Immersion (Zone 1)

(Mining Only)

p Pressurized (Zone 1)

IIA Propane

IP2x Objects >12mm

q Powder Filling (Zone 1)

IIB Ethylene

IP3x Objects >2.5mm

IPx3 Sprayed water

n* Non-Sparking (Zone 2)

IIC Acetylene/Hydrogen

IP4x Objects >1mm

IPx4 Splashed water

*denotes additional sub-categories

IIB+H2 Hydrogen

IP5x Dust protected

IPx5 Water jets

II All Gases

IP6x Dust-tight

IPx6 Heavy seas
IPx7 Effects of immersion
IPx8 Indefinite immersion

48
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 49

Hazardous Location Marking
ATEX Directive

The New Conformity Mark

The ATEX Directive 94/9/EC was adopted by the European
Union (EU) to facilitate free trade in the EU by aligning the
technical and legal requirements in the Member States for
products intended for use in potentially explosive
atmospheres.

Under the old Explosive Atmospheres and
Gassy Mines Directive (79/117/EEC), the
“Epsilion x” symbol indicated conformity
with the CENELEC requirements. This
symbol was allowed to be applied to
products which were considered to be final
assemblies. Not empty enclosures or component parts such
as terminal blocks, operators, breather drains, plugs, etc.. The
“Epsilion x” symbol will move into the marking string and be
used to indicate explosion protection.

The ATEX Directive went into affect (on a voluntary basis)
on March 1, 1996. This Directive will become mandatory
effective on July 1, 2003. All Product intended for use in
explosive atmospheres must comply with this Directive in
order to be sold or placed in service in any Member State of
the European Union.

Under the New Directive, the “CE” mark
will now indicate conformity to the ATEX
Directive. This mark can only be placed on
final assemblies and not to empty
enclosures or component parts.

0539

3A–5

Equipment Marking

II 1 G

CE Conformity Marking

Type of Explosive Atmosphere
G Gas/Vapor/Mist (Zone 0, 2, 2)

Identification Number
of the notified body

D Dust (Zone 20, 21, 22)

(i.e. DEMKO)
Equipment Category
(Mining)

EU Explosive Protection Symbol

M1 Energized
Equipment Group

M2 De-energized

I Mining

(Non-Mining)

II Non-Mining

1 Very High Protection (Zone 0 & 20)
2 High Protection (Zone 1 & 21)
3 Normal Protection (Zone 2 & 22)

49
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 50

Selecting An Increased Safety Terminal Enclosure
Overview
Following the steps outlined below will guide you in selecting
the appropriate enclosure for your Increased Safety application.
Adherence to these Steps will ensure that the enclosure you
select will meet the requirements for Increased Safety
Certification.
STEPS:

STEP 2: Select a Terminal Block Manufacturer and
Terminal Block
Adalet Enclosures can utilize various manufacturers of
Terminal Blocks, select from:
• Entrelec
• Phoenix
• Wago

1. Select the Enclosure Series and Catalog Prefix.

• Weidmuller

2. Select a Terminal Block Manufacturer and Terminal Block.

• Wieland

3. Determine the Enclosure Size and Catalog Number.
4. Locate the Thermal Dissipation Chart for the Enclosure you
selected.

• Woretz
• Consult factory for others.
Beginning on the fourth page of each Enclosure Series
Section, you will find Tables for each of the above Terminal
Block Manufacturers. Select a Manufacturer and a Terminal
Block for your application.

5. Select the Wire Size for your Application.
6. Select the Current to be applied to the Wire.

STEP 1: Select the Enclosure Series and Catalog Prefix

3A–6

Select an Enclosure Series based on the environmental needs of
your application from these options:
TN Single Door Clamped Series:

If you have no preference for a specific Terminal Block
Manufacturer, use the Quick Selector found on the third page
of the Enclosure Section. Select the Wire size for your
application and Adalet will supply a suitable Terminal Block.

TN4 – Steel Powder Coated
STEP 3: Determine the Enclosure Size and
Catalog Number

TN4X – Stainless Steel 304
TN4X6 – Stainless Steel 316L

From the table selected in Step 2, the quantities that are
shown under a terminal block type indicates the maximum
number of terminal blocks for each enclosure size. (Warning:
These quantities may not qualify the Enclosure for an
Increased Safety Certification.) The column to the far left
indicates the catalog enclosure size. NOTE: This is also the
nominal outside dimension of the enclosure (i.e. –201407: 20”
length x 14” width x 07” depth).

TSC Screw Cover Series:
TSC4 – Steel Powder Coated
TSCX – Stainless Steel 304
TSC4X6 – Stainless Steel 316L
TFG Screw Cover Series:
TFG – Fiberglass Reinforced Polyester

Use the following steps:
For the Terminal Block Type selected, follow the column down
until the quantity meets or exceeds your requirement. Then
follow the row to the far left to find the catalog enclosure size.
If your quantity requirement is not met, select another
Terminal Block Type (most manufacturers build various sizes
of terminal blocks of the same wire size) or select another
Enclosure Series.
NOTE: You might want to consider having a few extra
Terminal Blocks for future expansion.

50
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 51

Selecting An Increased Safety Terminal Enclosure
IF THE TERMINAL BLOCK QUANTITY DOES NOT MEET
THE NEEDS OF YOUR APPLICATION, CONTINUE WITH
THE FOLLOWING STEPS

STEP 4: Locate the Thermal Dissipation Chart for the
Enclosure you selected.
Each enclosure size has a unique Thermal Dissipation Chart
used to qualify for Increased Safety Certification. These
charts can be found on the catalog page of the enclosure
style you selected. For quick reference, the catalog page
number is located in the column next to each enclosure size
in the Terminal Block Content tables used in Step 3.

STEP A: Reduce the Current for your Application
Follow the Conductor Cross Section column up until you find
the Terminal Count required for you application. Follow the
row across to the left to find the maximum allowable Current.

STEP 5: Select the Wire Size for your Application

IF THE CURRENT CANNOT BE REDUCED OR IS LESS
THAN WHAT IS REQUIRED, CONTINUE WITH STEPS
B OR C.

On the Thermal Dissipation Chart, locate the row listing
Conductor Cross Section. Follow the row across until you
find the wire size that will be connected to the terminal
block. NOTE: typically, a terminal block catalog number
indicates the maximum wire size that can be installed.

STEP B: Increase the Wire Size for your Application

On the Thermal Dissipation Chart, locate the column for
Current. Follow the column down until you find the current
that will be applied to the conductor. At the intersection of
the Current row and Conductor Cross Section column from
Step 5, you will find the maximum number of terminal blocks
allowed in the enclosure for an Increased Safety Certification.

3A–7

STEP 6: Select the Current to be Applied to the Wire

Determine if you can use a larger conductor size. If you
selected a 1.5mm2 conductor for a terminal block that will
accommodate a 2.5mm2 conductor, increase the Conductor
Size. This will increase the terminal block quantity. Find the
required quantity in the new Conductor Cross Section
column. Follow that row across to the left, this is the new
maximum Current.

IF THE CURRENT IS STILL LESS THAN REQUIRED,
CONTINUE TO STEP C.

If this meets your requirements, you are done.

STEP C: Select a Larger Size Enclosure
If neither the current or the conductor size can be changed.
Select the next size enclosure and repeat STEP 4-6. If none
of these Steps provides you with the necessary terminal
block or current, you might consider another Enclosure
Series, or consult Factory.

51
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 52

Increased Safety Enclosure Selection Examples
Enclosure Selection: Example 1

Enclosure Selection: Example 2

A customer requires a TSC4X-080804 Enclosure with (19)
Weidmuller SAK2.5 terminal blocks installed.

A customer can only fit a TSC4X-121206 Enclosure within their
skid package. They want (30) Weidmuller SAK2.5 terminal
blocks installed and they would like 16 Amps with 2.5mm2
conductors.

No information on Current or Conductor Size is given.
Question: Will (19) SAK2.5 terminal blocks fit in the enclosure?

Question: Will the enclosure qualify for Increased
Safety Certification?

SAK6N

Answer: Yes, from the chart above (19) SAK2.5
terminal blocks will fit.

SAK4

Chart reduced for clarity

SAK2.5

5
8
11
28
40
40
27
27

AKE4

6
10
14
17
50
50
33
33

AKE2.5

6
11
15
19
54
54
36
36

Cat. Page

SAK6N

6
9
13
34
72
72
31
31

Enclosure Size

SAK4

7
12
34
46
99
99
43
43

SAK2.5

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54

AKE4

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605

Question: Can (30) SAK2.5 terminal blocks fit in
a TSC4X-121206 enclosure?
Locate the Maximum Physical Content Chart for Weidmuller in
the TSC Section.

AKE2.5

Cat. Page

3A–8

Enclosure Size

Locate the Maximum Physical Content Chart for Weidmuller in
the TSC Section.

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58

7
12
34
46
99
99
43
43
86
86
172
172

6
9
13
34
72
72
31
31
62
62
93
93

6
11
15
19
54
54
36
36
36
36
108
108

6
10
14
17
50
50
33
33
33
33
99
99

5
8
11
28
40
40
27
27
54
54
81
81

Chart reduced for clarity

Locate the Thermal Dissipation Chart for the 080804 enclosure.
Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
55
####
####
####
####
####
Maximum fill permitted based solely
10
27
####
####
####
####
on minimum ####
wire bending space
16
9
17
69
####and electrical
#### clearances####
20
3
10
20
####
####
####
25
####
5
11
22
####
####
35
#### testing required,
####
3
8
21
####
Additional
Consult Factory
50
####
####
####
1
7
17

Answer: Yes, (19) SAK2.5 terminal blocks can be installed and
Increased Safety Certification given with a maximum
current of 10 Amps using 2.5mm2 wires.
Important: The Maximum Amperage and Conductor Size
has to be forwarded to the customer.

Answer: Yes, from the chart above the -121206 can fit (108)
terminal blocks.

Question: Will the enclosure qualify for Increased
Safety Certification?
Locate the Thermal Dissipation Chart for the 121206 enclosure.
Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
85
####
####
####
####
####
Maximum fill permitted based solely
10
41
####
####
####
####
on minimum ####
wire bending space
16
14
27
107
####and electrical
#### clearances####
20
5
16
31
####
####
####
25
####
7
17
33
####
####
35
#### testing required,
####
5
13
33
####
Additional
Consult Factory
50
####
####
####
1
10
27

Answer: No, from the chart above the -121206 can fit (27)
terminal blocks at 16 Amps with 2.5mm2 wire

52
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 53

Increased Safety Enclosure Selection Examples
Enclosure Selection: Example 2 Cont.

Question: Will the enclosure qualify for Increased
Safety Certification?

Question: What STEPS can you take.

Locate the Thermal Dissipation Chart for the 121206 enclosure.

Reminder: They can only use a –121206 enclosure.
Option 1: STEP A – Reduce the Current to be applied to Wire
Question: Will the customer accept a lower amperage?
Locate the Thermal Dissipation Chart for the 121206
enclosure.
Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
85
####
####
####
####
####
Maximum fill permitted based solely
10
41
####
####
####
####
on minimum ####
wire bending space
16
14
27
107
####and electrical
#### clearances####
20
5
16
31
####
####
####
25
####
7
17
33
####
####
35
#### testing required,
####
5
13
33
####
Additional
Consult Factory
50
####
####
####
1
10
27

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
85
####
####
####
####
####
Maximum fill permitted based solely
10
41
####
####
####
####
on minimum ####
wire bending space
16
14
27
107
#### and electrical
#### clearances####
20
5
16
31
####
####
####
25
####
7
17
33
####
####
35
#### testing ####
5
13
33
####
Additional
required,
Consult Factory
50
####
####
####
1
10
27

Answer: Yes, (30) SAK4 terminal blocks can be installed and
Increased Safety Certification given with a maximum
current of 16 Amps using 4mm2 wires.

3A–9

Answer: Reducing the Current to 10 Amps allows the
customer to stay in the –121206 Enclosure with
(30) SAK2.5 terminal blocks while qualifying the
enclosure for Increased Safety Certification.

Option 2: STEP B – Increase the Wire Size
Note: Increasing the conductor size will change the terminal
block size and may affect the enclosure size.
Question 1: Will the customer change wire size
and terminal block size?
Question 2: Will (30) SAK4 terminal block fit in the
-121206 enclosure?

SAK2.5

SAK4

SAK6N

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58

AKE4

Cat. Page

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208

AKE2.5

Enclosure Size

Locate the Maximum Physical Content Chart for Weidmuller
in the TSC Section.

7
12
34
46
99
99
43
43
86
86
172
172

6
9
13
34
72
72
31
31
62
62
93
93

6
11
15
19
54
54
36
36
36
36
108
108

6
10
14
17
50
50
33
33
33
33
99
99

5
8
11
28
40
40
27
27
54
54
81
81

Answer: Yes, from the chart above (30) SAK4
Terminal Blocks will fit.
53
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 A 12/9/01 10:43 AM Page 54

Increased Safety Enclosure Selection Examples
Enclosure Selection: Example 3

Question: What STEP must you take? Reminder: The current
is 16 Amps minimum with 2.5mm2 wire

A customer requires a TSC Series Enclosure with (30)
Weidmuller SAK2.5 terminal blocks installed. The Minimum
Current is 16 Amps with 2.5mm2 conductors.

Answer: STEP C - Select a Larger Enclosure

5
8
11
28
40
40
27
27

SAK6N

6
10
14
17
50
50
33
33

SAK4

6
11
15
19
54
54
36
36

SAK2.5

SAK6N

6
9
13
34
72
72
31
31

AKE4

SAK4

7
12
34
46
99
99
43
43

AKE2.5

SAK2.5

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54

AKE4

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605

AKE2.5

Cat. Page

3A–10

Enclosure Size

Locate the Maximum Physical Content Chart for Weidmuller
in the TSC Section.

Cat. Page

Question: What is the smallest enclosure that can fit (30)
SAK2.5 terminal blocks?

Enclosure Size

Locate the Maximum Physical Content Chart for Weidmuller in
the TSC Section.

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54

7
12
34
46
99
99
43
43

6
9
13
34
72
72
31
31

6
11
15
19
54
54
36
36

6
10
14
17
50
50
33
33

5
8
11
28
40
40
27
27

Chart reduced for clarity

Question: Will this enclosure qualify for Increased
Safety Certification?

Chart reduced for clarity

Locate the Thermal Dissipation Chart for the 101008 enclosure.

Answer: From the chart above the smallest enclosure
–101006 can fit (54) terminal blocks.

Question: Will the enclosure qualify for Increased
Safety Certification?
Locate the Thermal Dissipation Chart for the 101006 enclosure.
Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
77
####
####
####
####
####
Maximum fill permitted based solely
10
37
####
####
####
####
on minimum ####
wire bending space
16
13
25
97
####and electrical
#### clearances####
20
5
14
28
####
####
####
25
####
7
16
30
####
####
35
#### testing required,
####
4
12
30
####
Additional
Consult Factory
50
####
####
####
1
9
24

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
92
####
####
####
####
####
Maximum fill permitted based solely
10
45
####
####
####
####
on minimum ####
wire bending space
16
15
30
116
####and electrical
#### clearances####
20
6
17
33
####
####
####
25
####
8
19
36
####
####
35
#### testing required,
####
5
14
35
####
Additional
Consult Factory
50
####
####
####
2
11
29

Answer: YES.

The TSC Series –101008 enclosure with (30) SAK2.5 terminal
blocks will qualify for Increased Safety Certification at 16 Amps
with 2.5mm2 conductors.

Answer: The terminal block quantity does not meet the
customer’s requirement for (30) terminal blocks.

54
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 55

TN4 Series - Single Door Clamped Style
Options
Gland Plates
These removable plates offer great flexibility for the end user to
drill holes without having to remove the entire enclosure from
the installation site.
Add the following Suffixes:
-A: Gland Plate installed on top of box.
-B: Gland Plate installed on bottom of box.
-C: Gland Plate installed on left of box.
-D: Gland Plate installed on right of box.
For multiple gland plates omit dashes (i.e. TN4X-201407-ABCD).
Note that sizes 251807, 302207, 362507 and 392907 are
furnished standard with multiple gland plates.
Conduit/Cable Entries:

3B–1

Entries can be provided per a customer sketch or with detailed
information on the entry locations. Please refer to Entry Spacing
Tables at the end of the Increased Safety Section in the
CENELEC Product Catalog. Note: This information is important
and could affect the size of the enclosure you selected.
Close-up Plugs:

85 Enclosure Sizes
Available in 85 sizes, from 16”x12”x6” (model 161206)
to 60”x36”x12” (model 603612).

Any unused entries must be plugged with a Certified Close-Up
Plug. Adalet can provide close-up plugs in various styles and
materials. Please indicate on the sketch or provide detailed
information of holes to be plugged.
Enclosure Labeling:

Construction
• Available in (3) Materials: SS304, SS316L, PowderCoated (ASA61 Grey) Steel.
• Folded Lip around the Door Opening to provide
complete and maximum gasket seal.
• Continuously Welded and Ground Smooth Seams.
• Continuous One-Piece Silicone Gasket (sizes 2014,
2518, 3022, 3625, 3929).
• Silicone Strip Gasket For All Other Sizes.
• Welded on External Mounting Feet with 5/16”
Clearance Holes/Slot.
• External Door Clamps.
• Continuous Piano Type Hinge with Removable SS
Hinge Pin.

Adalet can provide additional enclosure labeling with custom silk
screening or various colors of Lamacoid™ nameplates. Please
provide detailed information of the logo or text required.
Breather Drains:
Breather Drains can be provided per customer request. They are
available in Brass or Stainless Steel 316L. Please indicate on a
sketch or provide detailed information for locations.
Grounding Busbars:
Some applications might require grounding points to be
terminated in the enclosure. With the use of a Ground Busbar
System this can be accomplished, consult factory for options.
Mounting Pans:

• Internal/External Earthing Stud.

As an alternative to the universal rail mounting system,
mounting pans are available in steel/powder coated, stainless
steel, and aluminum. Please indicate when requesting quote.

• Universal Rail Mounting System.

Terminal Strip Assemblies:

• Padlock Hasp & Staple for Padlocking.

Various options (i.e. marking tags, protective covers, jumpers,
partitions, etc.) are available. Please provide detailed information
requesting quote.

• Ground Studs on Box and Cover.

55
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 56

TN4 Series - Single Door Clamped Style
General Information
Adalet's Single Door Clamped Terminal Enclosures are available
in Stainless Steel 316L & 304 and Carbon Steel. Adalet can also
supply custom size enclosures, operators, and components to
suit your Increased Safety Application. Silicone gaskets,
removable hinge pin, box & cover ground studs including an
internal/external earthing stud, along with internal standoffs and
universal rail mounting system are included as standard.

Enclosure Certifications with Terminals

3B–2

0539
II 2GD
EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Empty Enclosure Certifications
0539
II 2GD
EEx e II
Ex e II
Class I, Zone 1, AEx e II
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Working Voltage
Terminal Blocks
Various manufacturers
Material
TN4 Series
TN4X Series
TN4X6 Series
TN4 Series Gland Plates
TN4X Series Gland Plates
TN4X6 Series Gland Plates
Mounting Pan
Gasket
Cover
Gland Plates
Lid Fixing
Hinge
TN4 Series
TN4X Series
TN4X6 Series
Door Clamps
TN4 Series
TN4X Series
TN4X6 Series
Enclosure Mounting
All Types
Gland Plate Hardware
All Types
Grounding
Box & Cover
All Types
Earthing Stud
All Types
Impact Resistant
All Types
Ambient Temperature Range
All Types

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50

D

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50
1100 Volts Maximum
EEx e type with wire sizes 1.5mm up to 240mm
#14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray
#14ga Stainless Steel 304, Brushed Finish
#14ga Stainless Steel 316, Brushed Finish
#10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray
#10ga Stainless Steel 304, Brushed Finish
#10ga Stainless Steel 316, Brushed Finish
#14ga Cold Rolled Steel, Polyster Powder Coated White
Silicone Sponge
Silicone Sponge
Continuous piano type - Steel with removable SS304 pin
Continuous piano type - SS304 with removable pin
Continuous piano type - SS316 with removable pin
Plated Steel Clear
Stainless Steel 304
Stainless Steel 316
Four (4) external lugs with .44" clearance holes/slots
300 Series stainless steel
1/4-20 Stud with 300 series stainless steel hardware
1/4-20 Stud - All components brass
7 Nm to EN50014/EN50019
-40°C to +70°C to EN50014

D

56
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 57

TN4 Series - Quick Selector
Enclosure Selection
1. Using the table below, select the terminal block size
for your application.
2. Follow the column down until you find the quantity
required for your application.
3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size for your
application.
4. To complete Catalog Number, refer to Catalog Page
indicated next to Enclosure Size you selected.
5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.
For Increased Safety Applications
1. Refer to Catalog Page indicated next to the Enclosure
Size you selected for Heat Dissipation Table.

Maximum Physical Terminal Block Content
2.5mm

4mm

6mm

10mm 16mm

35mm

50mm 70mm 95mm 120mm 150mm 185mm 240mm

-201407

3B–7

222

183

168

184

111

62

23

0

0

0

0

0

0

0

-251807

3B–8

500

410

380

305

200

126

31

25

22

10

0

0

0

0

-302207

3B–9

750

618

570

462

310

156

78

31

28

13

0

0

0

0

-362507

3B–10

1092

896

826

672

468

260

96

78

35

16

24

16

0

0

-392907

3B–11

1368

1120

1032

840

595

355

159

84

76

34

26

17

0

0

3B–3

TN4 Series
Enclosure Catalog
Sizes
Page 1.5mm

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.
2. Quantities shown above are for Adalet supplied standard terminal blocks.

57
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 58

Maximum Physical Terminal Block Content
Enclosure Selection
1. Using the table below, select the terminal block type for your application.
2. Follow the column down until you find the quantity required for your application.
3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application.
4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected.
For Increased Safety Applications
1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table.

0
14
17
22
48

M1,5/6.HH

MTC6

MA2,5/5.SNB

M4/6.SN

M4/6.SNB

M6/8.SNB

M4/8.SN

183
410
618
896
1128

183
410
618
896
1128

138
310
468
679
848

138
248
390
582
742

183
410
618
896
1128

183
410
618
896
1128

183
410
618
896
1128

138
310
468
679
848

138
310
468
679
848

M120/35

M70.31.AF
0
16
20
50
54

219
490
738
1071
1344

D6/8.ADO

14
38
48
90
99

183
410
618
896
1128

D6/8…ADO

0
0
15
18
20

183
328
515
768
987

D4/6.ADO

0
14
17
22
48

M35/26.AF

M70/31.FF
0
16
20
50
54

183
328
515
768
987

D4/6.ADO.T

14
38
48
90
99

M4/6.H

M35/16

248
498
728
1161
1420

0
22
28
35
76

M300/42.AF

M16/12

23
31
78
96
159

M70/22

M10/10

62
123
208
256
355

M120/35.AF

M6/8

111
196
310
462
595
M300/42.FF

M4/6

138
310
468
679
848
M120/35.FF

MA2,5/5.1

183
410
618
896
1128

M35/26.FF

MA2,5/5

219
490
738
1071
1344

DR4/6

Cat. Page
3B–7
3B–8
3B–9
3B–10
3B–11

219
490
738
1071
1344

D4/6…ADO

-201407
-251807
-302207
-362507
-392907

3B–7
3B–8
3B–9
3B–10
3B–11

0
0
0
0
20

0
14
17
22
48

Notes: 1. All quantities shown are for terminal blocks installed in vertical rows.

62
126
156
260
355

23
31
78
96
159

0
22
28
35
76

12
16
20
50
56

12
16
20
50
56

12
16
20
50
56

WFF120

ZDU2.5

ZDU4

ZDU6

AKZ2.5

AKZ4

AKE2.5

305
486
816
1143
1540

296
594
875
1395
1700

0
14
18
23
50

0
14
18
23
50

0
14
18
23
50

0
10
13
16
34

SAKG 46 II

111
200
310
468
595

370
594
1000
1395
1870

SAKG 40 III

184
305
462
672
840

138
244
385
480
630

SAKG 40 II

168
380
570
826
1032

183
328
515
640
840

SAKG 40 I

183
410
618
896
1120

219
392
615
918
1176

SAKG 32 III

216
365
637
904
1125

0
0
0
18
19

SAKG 32 II

3B–7
3B–8
3B–9
3B–10
3B–11

0
0
19
23
25

SAKG 32 I

-201407
-251807
-302207
-362507
-392907

WFF70

0
17
22
54
60

SAKG 28 III

WWF35

0
0
0
24
26

SAKG 28 II

WDU120

0
0
23
29
31

SAKG 28 I

WDU70

23
31
78
96
106

SAK70

WDU35

62
84
156
260
284

SAK35N

WDU16

74
150
252
390
516

SAK16

WDU10

141
252
395
594
756

SAK10

WDU6

222
400
625
936
1197

SAK6N

WDU4

222
400
625
936
1197

SAK4

WDU2.5

222
500
750
1092
1368

SAK2.5

WDU2.5N

3B–7
3B–8
3B–9
3B–10
3B–11

AKE4

Cat. Page

-201407
-251807
-302207
-362507
-392907

Cat. Page

Enclosure
Size

Manufacturer - Weidmuller

Enclosure
Size

3B–4

Enclosure
Size

-201407
-251807
-302207
-362507
-392907

Cat. Page

Enclosure
Size

Manufacturer - Entrelec

0
10
13
16
34

0
10
13
16
34

0
0
0
16
17

Notes: 1. All quantities shown are for terminal blocks installed in vertical rows.
2. Weidmuller WFF Series are installed on a mounting pan.
58
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 59

Maximum Physical Terminal Block Content
Enclosure Selection
1. Using the table below, select the terminal block type for your application.
2. Follow the column down until you find the quantity required for your application.
3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application.
4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected.
For Increased Safety Applications
1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table.

3424 gr

3425 gr

3426 gr

3427 gr

3428 gr

3429 gr

30841 grEx

30842 gr Ex

30843 gr Ex

30844 gr Ex

3468 gr Ex

3469 gr Ex

30111 gr

3301 gr

186
336
525
780
1144

141
248
390
582
856

82
168
280
435
570

68
90
171
284
390

26
35
90
110
122

0
21
27
34
74

90
160
300
434
544

78
136
215
324
413

44
90
114
188
260

18
24
60
74
123

0
18
22
56
60

0
0
18
23
25

186
336
630
910
1144

186
336
525
780
1144

Cat. Page

3302 gr

3303 gr

3304 gr

3305 gr

3306 gr

3712 gr Ex

3713 gr Ex

3713/16 gr Ex

3714 gr Ex

3715 gr Ex

3716 gr Ex

30831 gr Ex

30832 gr Ex

30833 gr Ex

30834 gr Ex

-201407
-251807
-302207
-362507
-392907

3B–7
3B–8
3B–9
3B–10
3B–11

141
248
390
582
856

82
168
280
435
570

68
90
171
284
390

26
35
90
110
122

0
21
27
33
74

81
180
270
392
488

69
124
195
294
371

38
78
99
164
225

17
22
56
70
117

0
18
22
56
60

0
0
18
23
25

90
200
300
434
544

78
136
215
324
413

44
90
114
188
260

18
24
60
74
123

3B–5

30128 gr

3B–7 186
3B–8 336
3B–9 630
3B–10 910
3B–11 1144

Enclosure
Size

-201407
-251807
-302207
-362507
-392907

Cat. Page

Enclosure
Size

Manufacturer - Woretz

Notes: 1. All quantities shown are for terminal blocks installed in vertical rows.

59
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 60

Maximum Physical Terminal Block Content
Enclosure Selection
1. Using the table below, select the terminal block type for your application.
2. Follow the column down until you find the quantity required for your application.
3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application.
4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected.
For Increased Safety Applications
1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table.

ZFK 6

MBK 2,5/E-EX
300
486
808
1134
1518

ZFK 4

UKH 150
0
0
0
0
27

ZKF 2,5

UKH 95
0
20
25
31
68

ZFK 1,5

UKH 50
0
25
31
78
84

MZDB 1,5-NS 35

UK 35
24
33
82
102
168

MZDB 1,5

UK 16 N
60
123
204
256
350

MZB 1,5-NS 35

UK 10 N
108
196
305
456
588

MZB 1,5

UK 6 N
135
305
456
665
832

UK 3-RETURN

UK 5 N
180
405
606
882
1104

180 216
305 384
532 720
760 900
936 1312

288
480
840
1200
1476

216
480
720
1050
1312

144
240
427
600
747

108
240
366
525
664

267
476
750
1116
1428

216
384
600
900
1148

180
324
505
756
966

135
183
304
475
624

MBK 6/E

UK 3 N
216
480
720
1050
1312

Cat. Page

-201407 3B–7 216
-251807 3B–8 480
-302207 3B–9 720
-362507 3B–10 1050
-392907 3B–11 1312

Enclosure
Size

UK 2,5 N

Manufacturer - Phoenix

264-225

21 213
29 380
72 595
90 882
147 1134

264-125

283-691
62
126
156
260
355

264-220

284-691
74
150
252
390
510

264-120

282-691
141
252
390
490
642

281-693

281-991
183
324
510
756
973

280-698

281-691
183
324
510
756
966

285-691

280-991

Cat. Page

Enclosure
Size

-201407 3B–7 213
-251807 3B–8 380
-302207 3B–9 595
-362507 3B–10 882
-392907 3B–11 1134

183 252 180
324 420 300
510 735 525
630 1040 744
973 1287 918

252
420
630
910
1287

148
250
378
546
765

WK 4/U

WK 6/U

WKI 35/U

WKN 10/U

WKN 16/U

WKN 35/U

WKN 70/U

WKN 150/U

-201407 3B–7 222
-251807 3B–8 495
-302207 3B–9 750
-362507 3B–10 1085
-392907 3B–11 1360

186
415
624
903
1136

138
248
468
582
848

37
49
124
154
170

74
147
248
385
510

62
82
156
256
284

23
31
39
96
106

0
20
26
32
70

0
0
0
27
30

Cat. Page

WK 2.5/U

Manufacturer - Wieland
Enclosure
Size

3B–6

Manufacturer - Wago

Notes: 1. All quantities shown are for terminal blocks installed in vertical rows.

60
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 61

TN4 Series - Single Door Clamped 20''x 14''x 7''
SS316L Enclosures with Terminals
CATALOG NUMBER
TN4X6-201407
TN4X6-201407-A
TN4X6-201407-B
TN4X6-201407-C
TN4X6-201407-D
TN4X6-201407-AB
TN4X6-201407-CD
TN4X6-201407-ABCD

GLAND PLATES
NONE
SIDE A
SIDE B
SIDE C
SIDE D
SIDE A & B
SIDE C & D
SIDE A, B, C, & D

1. For Stainless Steel 304 assemblies substitute
TN4X6 prefix with TN4X.
2. For Steel Powder Coated assemblies
substitute TN4X6 prefix with TN4.
3. For empty Enclosure add U immediately
following enclosure size (i.e. TN4X6-201407U).

Size
NPT
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2

Qualifying Enclosure for Increased
Safety Certification
1. Find the Wire Size (conductor) you
intend to use to connect to terminal
block.
2. Find the Current (amperage) you intend
to apply to the conductor.
3. The intersection of the Wire Size
(column) and Current (row) gives you
the maximum number of terminal
blocks permitted for proper heat
dissipation and Increased Safety
Certification.
4. If the terminal count is too small,
decrease the current or increase the
wire size until the desired terminal
count is found. If neither is possible,
continue to the next size enclosure
until the desired terminal count is
found.

3B–7

Gland Plate Entries
Maximum Number of Entries
Sides A & B Sides C & D
18
22
14
18
12
14
4
6
4
5
3
4
3
3

Metric
M16
M20
M25
M32
M40
M50
M63

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315

1.5
110
53
18
7

2.5

4

35
20
9

138
40
22
6

Maximum Terminal Block Wire Size (mm2)
6
10
16
25
35
50

70

95

120

150

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
43
17
2

42
14
4

Additional Testing Required,
Consult Factory

Notes:
1. See end of this section for applications using Multiple Terminal Block Types.
2. For other manufacturers of EE x 'e' type terminal blocks, consult factory.
3. For conduit/cable entry spacings and minimum wire bending space
requirements, refer to the end of this section.

35
16
6

58
18
7

65
17
7

17
6

15
5
2

13
7
4

41
16
9
2

20
5

The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.
61

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 62

TN4 Series - Single Door Clamped 25''x 18''x 7''
SS316L Enclosures with Terminals
CATALOG NUMBER
TN4X6-251807
TN4X6-251807-A
TN4X6-251807-B
TN4X6-251807-C
TN4X6-251807-D
TN4X6-251807-AB
TN4X6-251807-CD
TN4X6-251807-ABCD

GLAND PLATES
NONE
SIDE A
SIDE B
SIDE C
SIDE D
SIDE A & B
SIDE C & D
SIDE A, B, C, & D

1. For Stainless Steel 304 assemblies substitute
TN4X6 prefix with TN4X.
2. For Steel Powder Coated assemblies
substitute TN4X6 prefix with TN4.
3. For empty Enclosure add U immediately
following enclosure size (i.e. TN4X6-251807U).

3B–8

Gland Plate Entries
Size
NPT
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2

Metric
M16
M20
M25
M32
M40
M50
M63

Maximum Number of Entries*
Sides A & B Sides C & D
24
12
20
10
16
8
6
3
5
3
4
2
4
2

*Note: There are (2) Gland Plates on Sides C&D.
Quantity shown is for (1) Plate

Qualifying Enclosure for Increased
Safety Certification
1. Find the Wire Size (conductor) you
intend to use to connect to terminal
block.
2. Find the Current (amperage) you intend
to apply to the conductor.
3. The intersection of the Wire Size
(column) and Current (row) gives you
the maximum number of terminal
blocks permitted for proper heat
dissipation and Increased Safety
Certification.
4. If the terminal count is too small,
decrease the current or increase the
wire size until the desired terminal
count is found. If neither is possible,
continue to the next size enclosure
until the desired terminal count is
found.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400

1.5
127
61
21
8

2.5

4

41
24
11

159
46
26
7

6

Maximum Terminal Block Wire Size (mm2)
10
16
25
35
50
70

95

120

150

185

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
50
19
2

49
16
5

Additional Testing Required,
Consult Factory

Notes:
1. See end of this section for applications using Multiple Terminal Block Types.
2. For other manufacturers of EE x 'e' type terminal blocks, consult factory.
3. For conduit/cable entry spacings and minimum wire bending space
requirements, refer to the end of this section.

40
18
7

67
21
9

75
19
8

20
6

17
6
2

15
8
4

47
18
11
2

23
6

14
3

The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

62
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 63

TN4 Series - Single Door Clamped 30''x 22''x 7''
SS316L Enclosures with Terminals
CATALOG NUMBER
TN4X6-302207
TN4X6-302207-A
TN4X6-302207-B
TN4X6-302207-C
TN4X6-302207-D
TN4X6-302207-AB
TN4X6-302207-CD
TN4X6-302207-ABCD

GLAND PLATES
NONE
SIDE A
SIDE B
SIDE C
SIDE D
SIDE A & B
SIDE C & D
SIDE A, B, C, & D

1. For Stainless Steel 304 assemblies substitute
TN4X6 prefix with TN4X.
2. For Steel Powder Coated assemblies
substitute TN4X6 prefix with TN4.
3. For empty Enclosure add U immediately
following enclosure size (i.e. TN4X6-302207U).

Size
NPT
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2

3B–9

Gland Plate Entries
Maximum Number of Entries*
Sides A & B Sides C & D
12
18
10
14
8
12
3
4
3
4
2
3
2
3

Metric
M16
M20
M25
M32
M40
M50
M63

*Note: There are (2) Gland Plates on All Sides.
Quantity shown is for (1) Plate.

Qualifying Enclosure for Increased
Safety Certification
1. Find the Wire Size (conductor) you
intend to use to connect to terminal
block.
2. Find the Current (amperage) you intend
to apply to the conductor.
3. The intersection of the Wire Size
(column) and Current (row) gives you
the maximum number of terminal
blocks permitted for proper heat
dissipation and Increased Safety
Certification.
4. If the terminal count is too small,
decrease the current or increase the
wire size until the desired terminal
count is found. If neither is possible,
continue to the next size enclosure
until the desired terminal count is
found.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
143
69
24
10

2.5

4

46
27
12

180
52
29
6

6

Maximum Terminal Block Wire Size (mm2)
10
16
25
35
50
70

95

120

150

185

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
57
22
3

55
18
6

Additional Testing Required,
Consult Factory

Notes:
1. See end of this section for applications using Multiple Terminal Block Types.
2. For other manufacturers of EE x 'e' type terminal blocks, consult factory.
3. For conduit/cable entry spacings and minimum wire bending space
requirements, refer to the end of this section.

46
21
8

75
23
10

84
22
9

22
7

20
7
2

17
10
5

53
21
12
2

26
7

15
3

11
1

The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.
63

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 64

TN4 Series - Single Door Clamped 36''x 25''x 7''
SS316L Enclosures with Terminals
CATALOG NUMBER
TN4X6-362507
TN4X6-362507-A
TN4X6-362507-B
TN4X6-362507-C
TN4X6-362507-D
TN4X6-362507-AB
TN4X6-362507-CD
TN4X6-362507-ABCD

GLAND PLATES
NONE
SIDE A
SIDE B
SIDE C
SIDE D
SIDE A & B
SIDE C & D
SIDE A, B, C, & D

1. For Stainless Steel 304 assemblies substitute
TN4X6 prefix with TN4X.
2. For Steel Powder Coated assemblies
substitute TN4X6 prefix with TN4.
3. For empty Enclosure add U immediately
following enclosure size (i.e. TN4X6-362507U).

3B–10

Gland Plate Entries
Size
NPT
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2

Metric
M16
M20
M25
M32
M40
M50
M63

Maximum Number of Entries*
Sides A & B Sides C & D
14
22
12
18
10
14
4
6
3
5
3
4
2
3

*Note: There are (2) Gland Plates on All Sides.
Quantity shown is for (1) Plate.

Qualifying Enclosure for Increased
Safety Certification
1. Find the Wire Size (conductor) you
intend to use to connect to terminal
block.
2. Find the Current (amperage) you intend
to apply to the conductor.
3. The intersection of the Wire Size
(column) and Current (row) gives you
the maximum number of terminal
blocks permitted for proper heat
dissipation and Increased Safety
Certification.
4. If the terminal count is too small,
decrease the current or increase the
wire size until the desired terminal
count is found. If neither is possible,
continue to the next size enclosure
until the desired terminal count is
found.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
158
77
26
11

2.5

4

51
30
14

198
57
32
9

6

Maximum Terminal Block Wire Size (mm2)
10
16
25
35
50
70

95

120

150

185

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
62
24
3

61
20
6

Additional Testing Required,
Consult Factory

Notes:
1. See end of this section for applications using Multiple Terminal Block Types.
2. For other manufacturers of EE x 'e' type terminal blocks, consult factory.
3. For conduit/cable entry spacings and minimum wire bending space
requirements, refer to the end of this section.

50
23
9

83
26
11
1

93
24
10

25
8

22
7
3

19
11
5

58
23
14
3

29
8

17
3

12
1

The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

64
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 65

TN4 Series - Single Door Clamped 39''x 29''x 7''
SS316L Enclosures with Terminals
CATALOG NUMBER
TN4X6-392907
TN4X6-392907-A
TN4X6-392907-B
TN4X6-392907-C
TN4X6-392907-D
TN4X6-392907-AB
TN4X6-392907-CD
TN4X6-392907-ABCD

GLAND PLATES
NONE
SIDE A
SIDE B
SIDE C
SIDE D
SIDE A & B
SIDE C & D
SIDE A, B, C, & D

1. For Stainless Steel 304 assemblies substitute
TN4X6 prefix with TN4X.
2. For Steel Powder Coated assemblies
substitute TN4X6 prefix TN4.

3B–11

3. For empty Enclosure add U immediately
following enclosure size (i.e. TN4X6-392907U).

Gland Plate Entries
Size
NPT
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2

Maximum Number of Entries*
Sides A & B Sides C & D
18
24
14
20
12
16
4
6
4
5
3
4
3
4

Metric
M16
M20
M25
M32
M40
M50
M63

*Note: There are (2) Gland Plates on All Sides.
Quantity shown is for (1) Plate.

Qualifying Enclosure for Increased
Safety Certification
1. Find the Wire Size (conductor) you
intend to use to connect to terminal
block.
2. Find the Current (amperage) you intend
to apply to the conductor.
3. The intersection of the Wire Size
(column) and Current (row) gives you
the maximum number of terminal
blocks permitted for proper heat
dissipation and Increased Safety
Certification.
4. If the terminal count is too small,
decrease the current or increase the
wire size until the desired terminal
count is found. If neither is possible,
continue to the next size enclosure
until the desired terminal count is
found.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
173
84
28
12

2.5

4

56
32
15

217
63
35
10

6

Maximum Terminal Block Wire Size (mm2)
10
16
25
35
50
70

95

120

150

185

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
68
27
4

66
21
7

Additional Testing Required,
Consult Factory

Notes:
1. See end of this section for applications using Multiple Terminal Block Types.
2. For other manufacturers of EE x 'e' type terminal blocks, consult factory.
3. For conduit/cable entry spacings and minimum wire bending space
requirements, refer to the end of this section.

55
25
9

91
28
12
1

102
27
10

27
9

24
8
3

20
12
6

64
25
15
3

32
9

19
4

13
1

The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.
65

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 66

Qualifying Enclosures for Increased Safety Certification
With Multiple Terminal Block Types
Current
(amps)
8
10
16
20
25
35
50

1.5
90
44
15
6

Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10

29
17
8

113
33
18
5

Additional Testing Required,
Consult Factory

16

Maximum fill permitted based solely
on minimum wire bending space and
electrical clearances

36
14
2

35
11

29

Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below.
Example:
Current

Number

2.5

16

7 (of 29)

=

24%

4

20

16 (of 33)

=

48%

10

35

9 (of 35)

=

26%

Total

=

98%

3B–12

Conductor Size

% of Maximum Terminal Population

<

100%

Notes:
1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor
size and the continuous current for the designated enclosures.
2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and
manufacturer's instructions.
3. Grounding terminals, bridges and grounding conductors are not counted.
4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges.
5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals
and conductors should be considered.
6. Combinations not covered by the above tables may be permitted if they are determined acceptable by test.

66
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 67

Conduit/Cable & Wire Bending Guidelines
Table A - Minimum Spacing Between Centers of Conduit or Cable Entries
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

NPT

METRIC

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

1/16 ~ 3/8

--

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

1-1/8
[29mm]

1/2

M16

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

3/4

M20

4-1/2
[115mm]

3-3/4
[96mm]

3-1/2
3-1/8
[89mm] [80mm]

2-3/4
[70mm]

2-1/2
[64mm]

2-1/8
[54mm]

2
[51mm]

1-3/4
[45mm]

1-1/2
[38mm]

1

M25

4-5/8
[118mm]

3-7/8
[99mm]

3-5/8
3-1/4
[92mm] [83mm]

2-7/8
[74mm]

2-3/4
[70mm]

2-1/4
[58mm]

2-1/8
[54mm]

1-7/8
[48mm]

1-1/4

M32

4-7/8
[124mm]

4-1/8
[105mm]

3-7/8
[99mm

3-1/2
[89mm]

3-1/8
[80mm]

2-7/8
[74mm]

2-1/2
[64mm]

2-3/8
[61mm]

1-1/2

M40

5
[127mm]

4-1/4
4
3-5/8
[108mm] [102mm] [92mm]

3-1/4
[83mm]

3
[77mm]

2-5/8
[68mm]

2

M50

5-3/8
[137mm]

4-3/4
4-1/2
4
3-5/8
[121mm] [115mm] [102mm] [92mm]

3-3/8
[86mm]

2-1/2

M63

5-1/2
[140mm]

4-7/8
4-5/8
4-1/4
3-7/8
[124mm] [118mm] [108mm] [99mm]

3

M75

5-7/8
[150mm]

5-1/4
5
4-5/8
[134mm] [127mm] [118mm]

3-1/2

--

6-1/4
[159mm]

5-3/4
5-1/2
[147mm] [140mm]

4

--

6-7/8
[175mm]

6
[153mm]

5

--

7-3/8
[188mm]

3B–13

SIZE

This information is compiled from data which we believe is
reliable and is given in good faith. Since the methods of
application and condition under which our products are used are
beyond our control, we are not able to guarantee the application
and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

2-13/16
[72mm]

2-1/4
[58mm]

2
[51mm]

1-3/16
[31mm]

1
[26mm]

7/8
[23mm]

11/16
[18mm]

9/16
[14mm]

1/2
[13mm]

1/2
[13mm]

METRIC

1-3/4
1-7/16
[45mm] [37mm]

Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls
AWG

16

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

250

350

400

500

mm sq.

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

1-1/2
1-1/2 1-1/2 1-1/2
2
3
3-1/2
5-1/2
6
6-1/2
7
8-1/2
10
12
13
14
[38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm]
Notes:
1. The distances in Table A are recommended minimum
distances between centers of conduit and cable gland
entries. Consult manufacturer of conduit fitting or cable
glands for their recommended minimum spacing.

entries to the edge of an opening or inside wall of box.
Consult manufacturer of conduit fitting or cable glands for
their recommended minimum spacing.
3. The distances in Table C are the minimum wire bending
space requirements between terminals, partitions, or inside
walls.

2. The distances in Table B are recommended minimum
distances between center of conduit and cable gland

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

67

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 68

TN4 Expanded Series - Single Door Clamped Style
General Information
Adalet's Single Door Clamped Terminal Enclosures are available
in Stainless Steel 316L & 304 and Carbon Steel. Adalet can also
supply custom size enclosures, operators, and components to
suit your Increased Safety Application. Silicone gaskets,
removable hinge pin, box & cover ground studs including an
internal/external earthing stud, along with internal standoffs for
mounting pans are included as standard.

Enclosure Certifications with Terminals

3B–14

0539
II 2GD
EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Empty Enclosure Certifications
0539
II 2GD
EEx e II
Ex e II
Class I, Zone 1, AEx e II
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Working Voltage
Terminal Blocks
Various manufacturers
Material
TN4 Series
TN4X Series
TN4X6 Series
TN4 Series Gland Plates
TN4X Series Gland Plates
TN4X6 Series Gland Plates
Mounting Pan
Gasket
Cover
Lid
Fixing Hinge
TN4 Series
TN4X Series
TN4X6 Series
Door Clamps
TN4 Series
TN4X Series
TN4X6 Series
Enclosure Mounting
All Types
Gland Plate Hardware
All Types
Grounding
Box & Cover
All Types
Earthing Stud
All Types
Impact Resistant
All Types
Ambient Temperature Range
All Types

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50

D

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50
1100 Volts Maximum
EEx e type with wire sizes 1.5mm up to 240mm
#14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray
#14ga Stainless Steel 304, Brushed Finish
#14ga Stainless Steel 316, Brushed Finish
#10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray
#10ga Stainless Steel 304, Brushed Finish
#10ga Stainless Steel 316, Brushed Finish
#14ga Cold Rolled Steel, Polyster Powder Coated White
Silicone Sponge
Continuous piano type - Steel with removable SS304 pin
Continuous piano type - SS304 with removable pin
Continuous piano type - SS316 with removable pin
Plated Steel Clear
Stainless Steel 304
Stainless Steel 316
Four (4) external lugs with .44" clearance holes/slots
300 Series stainless steel
1/4-20 Stud with 300 series stainless steel hardware
1/4-20 Stud - All components brass
7 Nm to EN50014/EN50019
-40°C to +70°C to EN50014

D

68
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 69

TN4 Expanded Series - Quick Selector
4. To complete Enclosure Size, Refer to Catalog Page 3B–24
for Enclosure Prefix and Depth.

Enclosure Selection
1. Using the table below, select the terminal block size for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications
1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

TN4 Series

2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

Maximum Physical Terminal Block Content

Heat

Enclosure Dissipation
Table

1.5mm

2.5mm

4mm

6mm

10mm 16mm

35mm

50mm 70mm 95mm 120mm 150mm 185mm 240mm

-1224XX

1224

204

168

156

147

102

56

20

16

7

3

5

0

0

0

-1612XX

1612

162

132

123

99

54

22

0

0

0

0

0

0

0

0

-1616XX

1616

216

176

164

132

81

44

17

13

12

0

0

0

0

0

-1620XX

1620

270

220

205

198

135

66

17

13

12

5

0

0

0

0

-2012XX

2012

222

183

168

138

74

31

0

0

0

0

0

0

0

0

-2016XX

2016

296

244

224

184

111

62

23

18

16

0

0

0

0

0

-2020XX

2020

370

305

280

276

185

93

23

18

16

7

0

0

0

0

-2024XX

2024

444

366

336

322

222

124

46

36

16

7

11

0

0

0

-2412XX

1224

285

234

216

174

94

39

0

0

0

0

0

0

0

0

-2416XX

2416

380

312

288

232

141

78

29

23

21

0

0

0

0

0

-2420XX

2024

475

390

360

348

235

117

29

23

21

9

0

0

0

0

-2424XX

2424

570

468

432

406

282

156

58

46

21

9

14

0

0

0

-2430XX

3024

760

624

576

522

329

195

87

46

42

18

14

9

0

0

-3016XX

3016

500

412

380

308

186

104

39

31

28

0

0

0

0

0

-3020XX

3020

625

515

475

462

310

156

39

31

28

13

0

0

0

0

-3024XX

3024

750

618

570

539

372

208

78

62

28

13

19

0

0

0

-3030XX

3030

1000

824

760

693

434

260

117

62

56

26

19

13

0

0

-3036XX

3036

1250

1030

950

847

558

312

117

93

84

26

38

13

11

11

-3624XX

3624

936

768

708

672

468

260

96

78

35

16

24

0

0

0

-3630XX

3036

1248

1024

944

864

546

325

144

78

70

32

24

16

0

0

-3636XX

3636

1560

1280

1180

1056

702

390

144

117

105

32

48

16

14

13

-4224XX

4224

1116

918

846

798

558

312

116

92

42

19

29

0

0

0

-4230XX

4230

1488

1224

1128

1026

651

390

174

92

84

38

29

19

0

0

-4824XX

4824

1302

1068

984

931

648

364

134

108

49

22

33

0

0

0

-4830XX

4830

1736

1424

1312

1197

756

455

201

108

98

44

33

22

0

0

-4836XX

4836

2170

1780

1640

1463

972

546

201

162

147

44

66

22

19

19

-6036XX

6036

2780

2280

2100

1881

1251

696

258

207

186

58

86

29

24

24

3B–15

Sizes

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.
2. Quantities shown above are for Adalet supplied standard terminal blocks.

69
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 70

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

Heat
Dissipation
Table

MA2,5/5…

MA2,5/5.1…

M4/6…

M6/8…

M10/10…

M16/12…

M35/16…

M70/22…

M4/6.H…

M1,5/6.HH

MTC6

MA2,5/5.SNB

M4/6.SN…

M4/6.SNB

M6/8.SNB

M4/8.SN

DR4/6…

3B–16

TN Series

Manufacturer - Entrelec

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

198
159
212
265
219
292
365
438
279
372
465
558
744
492
615
738
984
1230
918
1224
1530
1098
1464
1278
1704
2130
2730

198
159
212
265
219
292
365
438
279
372
465
558
744
492
615
738
984
1230
918
1224
1530
1098
1464
1278
1704
2130
2730

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

126
99
132
165
138
184
230
276
177
236
295
354
472
312
390
468
624
780
582
776
970
696
928
810
1080
1350
1730

80
54
81
108
74
111
148
185
94
141
188
235
329
186
248
310
434
558
385
539
693
465
651
540
756
972
1242

56
22
44
66
31
62
93
124
39
78
117
156
195
104
156
208
260
312
256
320
384
308
385
360
450
540
690

20
0
16
16
0
23
23
46
0
29
29
58
87
39
39
78
117
156
96
144
192
116
174
134
201
268
344

7
0
0
12
0
0
16
16
0
0
21
21
42
0
28
28
56
84
35
70
105
42
84
49
98
147
186

168
88
176
220
122
244
305
366
156
312
390
468
546
412
515
618
721
927
768
896
1152
924
1078
1074
1253
1611
2061

140
88
132
176
122
183
244
305
156
234
312
390
546
309
412
515
721
927
640
896
1152
770
1078
895
1253
1611
2061

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

198
159
212
265
219
292
365
438
279
372
465
558
744
492
615
738
984
1230
918
1224
1530
1098
1464
1278
1704
2130
2730

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

126
99
132
165
138
184
230
276
177
236
295
354
472
312
390
468
624
780
582
776
970
696
928
810
1080
1350
1730

126
66
99
132
92
138
184
276
118
177
236
354
413
234
312
468
546
702
582
679
873
696
812
810
945
1215
1557

232
180
225
315
248
310
434
496
316
395
553
632
790
520
728
832
1040
1352
1032
1290
1677
1240
1550
1440
1800
2340
2990

Notes:
1. See next page for more Entrelec terminal blocks.
2. All quantities shown are for terminal blocks installed in vertical rows.

70
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 71

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

Heat
Dissipation
Table

M35/26.FF

M70/31.FF

M120/35.FF

M300/42.FF

M35/26.AF

M70.31.AF

M120/35.AF

M300/42.AF

M120/35

M300/42

M400/52.AE

D4/6…ADO

D4/6.ADO.T…

D4/6.ADO…

D6/8…ADO

D6/8.ADO…

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

18
10
10
20
14
14
28
42
18
18
36
54
72
24
48
72
96
120
90
120
150
108
144
123
164
205
265

5
0
8
8
0
12
12
12
0
15
15
15
30
20
20
20
40
60
25
50
75
30
60
35
70
105
132

4
0
0
7
0
0
10
10
0
0
13
13
26
0
17
17
34
34
22
44
44
26
52
31
62
62
78

4
0
0
6
0
0
8
8
0
0
11
11
11
0
15
15
15
30
18
18
36
22
22
25
25
50
66

18
10
10
20
14
14
28
42
18
18
36
54
72
24
48
72
96
120
90
120
150
108
144
123
164
205
265

5
0
8
8
0
12
12
12
0
15
15
15
30
20
20
20
40
60
25
50
75
30
60
35
70
105
132

4
0
0
7
0
0
10
10
0
0
13
13
26
0
17
17
34
34
22
44
44
26
52
31
62
62
78

0
0
0
0
0
0
0
0
0
0
0
0
11
0
0
0
15
15
0
18
18
0
22
0
25
25
33

4
0
0
7
0
0
10
10
0
0
13
13
26
0
17
17
34
34
22
44
44
26
52
31
62
62
78

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
0
0
18
0
0
0
0
25
33

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
0
0
15
0
0
0
0
20
26

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
924
1232
1074
1432
1790
2290

126
99
132
165
138
184
230
276
177
236
295
354
472
312
390
468
624
780
582
776
970
696
928
810
1080
1350
1730

126
99
132
165
138
184
230
276
177
236
295
354
472
312
390
468
624
780
582
776
970
696
928
810
1080
1350
1730

3B–17

TN Series

Manufacturer - Entrelec

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

71
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 72

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

WDU10

WDU16

WDU35

WDU70

WDU120

WWF35

WFF70

WFF120

WFF185

WFF300

ZDU2.5

170
108
162
216
148
222
296
370
190
285
380
475
665
375
500
625
875
1000
780
1092
1248
930
1302
1085
1519
1736
2224

105
68
102
136
94
141
188
235
120
180
240
300
420
237
316
395
553
632
495
693
792
590
826
685
959
1096
1408

85
54
81
108
74
111
148
185
96
144
192
240
288
189
252
315
378
441
390
468
546
470
564
545
654
763
980

42
22
44
66
31
62
93
93
39
78
117
117
195
104
156
156
260
312
195
325
390
234
390
273
455
546
696

20
0
17
17
0
23
23
46
0
29
29
58
87
39
39
78
117
117
96
144
144
116
174
134
201
201
258

6
0
0
10
0
0
13
13
0
0
17
17
34
0
23
23
46
46
29
58
58
34
68
40
80
80
102

5
0
0
0
0
0
0
11
0
0
0
14
14
0
0
19
19
38
24
24
48
29
29
33
33
66
86

6
0
10
10
0
13
13
13
0
17
17
17
34
22
22
22
44
66
27
54
81
32
64
38
76
114
144

5
0
0
8
0
0
11
11
0
0
14
14
28
0
19
19
38
38
23
46
46
27
54
32
64
64
82

4
0
0
0
0
0
0
8
0
0
0
11
11
0
0
14
14
28
18
18
36
21
21
25
25
50
64

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
0
0
14
0
0
0
0
19
24

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
0
0
14
0
0
0
0
19
24

165
106
159
212
146
219
292
365
186
279
372
465
651
369
492
615
861
984
765
1071
1224
915
1281
1065
1491
1704
2184

140 105 297
88
66 216
132 99 270
176 132 378
122 92 296
183 138 370
244 184 518
305 230 666
156 116 376
234 174 470
312 232 658
390 290 846
546 406 1034
309 231 625
412 308 875
515 385 1125
721 539 1375
824 616 1625
640 480 1395
896 672 1705
1024 768 2015
765 570 1674
1071 798 2046
890 665 1944
1246 931 2376
1424 1064 2808
1824 1368 3601

AKE2.5

WDU6

170
108
162
216
148
222
296
370
190
285
380
475
665
375
500
625
875
1000
780
1092
1248
930
1302
1085
1519
1736
2224

AKZ4

WDU4

204
162
216
270
222
296
370
444
285
380
475
570
760
500
625
750
1000
1250
936
1248
1560
1116
1488
1302
1736
2170
2780

AKZ2.5

WDU2.5

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

ZDU6

WDU2.5N

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

ZDU4

Heat Dissipation
Table

3B–18

TN Series

Manufacturer - Weidmuller

243
176
220
308
244
305
427
549
308
385
539
693
847
510
714
918
1122
1326
1143
1397
1651
1368
1672
1593
1947
2301
2951

264
216
270
378
296
370
518
592
376
470
658
752
940
625
875
1000
1250
1625
1240
1550
2015
1488
1860
1728
2160
2808
3601

Notes:
1. See next page for more Weidmuller terminal blocks.
2. All quantities shown are for terminal blocks installed in vertical rows.
3. Weidmuller WFF Series are installed on a mounting pan.

72
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 73

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

SAKG 28 II

SAKG 28 III

SAKG 32 I

SAKG 32 II

SAKG 32 III

SAKG 40 I

SAKG 40 II

SAKG 40 III

SAKG 46 II

SAKG 54 II

147 102
99
54
132 81
198 135
138 74
184 111
276 185
322 222
174 94
232 141
348 235
406 282
522 329
308 186
462 310
539 372
693 434
847 558
672 468
864 546
1056 702
798 558
1026 651
931 648
1197 756
1463 972
1881 1251

56
22
44
66
31
62
93
124
39
78
117
156
195
104
156
208
260
312
260
325
390
312
390
364
455
546
696

20
0
17
17
0
23
23
46
0
29
29
58
87
39
39
78
117
117
96
144
144
116
174
134
201
201
258

7
0
12
12
0
16
16
16
0
21
21
21
42
28
28
28
56
84
35
70
105
42
84
49
98
147
186

10
0
9
9
0
12
12
24
0
15
15
30
30
20
20
40
40
60
50
50
75
60
60
70
70
105
138

10
0
9
9
0
12
12
24
0
15
15
30
30
20
20
40
40
60
50
50
75
60
60
70
70
105
138

10
0
9
9
0
12
12
24
0
15
15
30
30
20
20
40
40
60
50
50
75
60
60
70
70
105
138

5
0
0
8
0
0
11
11
0
0
14
14
28
0
18
18
36
36
23
46
46
27
54
31
62
62
80

5
0
0
8
0
0
11
11
0
0
14
14
28
0
18
18
36
54
23
46
69
27
54
31
62
93
120

5
0
0
8
0
0
11
11
0
0
14
14
28
0
18
18
36
36
23
46
46
27
54
31
62
62
80

3
0
0
5
0
0
7
7
0
0
9
9
18
0
13
13
26
26
16
32
32
19
38
22
44
44
58

3
0
0
5
0
0
7
7
0
0
9
9
18
0
13
13
26
26
16
32
32
19
38
22
44
44
58

3
0
0
5
0
0
7
7
0
0
9
9
18
0
13
13
26
26
16
32
32
19
38
22
44
44
58

0
0
0
0
0
0
0
0
0
0
0
0
9
0
0
0
13
13
0
16
16
0
19
0
22
22
29

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
0
0
13
0
0
0
0
19
24

3B–19

SAKG 28 I

156
123
164
205
168
224
280
336
216
288
360
432
576
380
475
570
760
950
708
944
1180
846
1128
984
1312
1640
2100

SAK70

SAK4

168
132
176
220
183
244
305
366
234
312
390
468
624
412
515
618
824
1030
768
1024
1280
918
1224
1068
1424
1780
2280

SAK35N

SAK2.5

200
117
195
234
162
270
324
432
207
345
414
552
690
455
546
728
910
1092
904
1130
1356
1088
1360
1264
1580
1896
2424

SAK16

AKE4

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

SAK10

Heat Dissipation
Table

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

SAK6N

TN Series

Manufacturer - Weidmuller

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

73
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 74

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

Heat Dissipation
Table

30128 gr

3424 gr

3425 gr

3426 gr

3427 gr

3428 gr

3429 gr

30841 gr Ex

30842 gr Ex

30843 gr Ex

30844 gr Ex

3468 gr Ex

3469 gr Ex

30111 gr

3301 gr

3B–20

TN Series

Manufacturer - Wortez

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

168
135
180
225
186
248
310
372
237
316
395
474
632
420
525
630
840
1050
780
1040
1300
936
1248
1086
1448
1810
2320

168
135
180
225
186
248
310
372
237
316
395
474
632
420
525
630
840
1050
780
1040
1300
936
1248
1086
1448
1810
2320

126
102
136
170
141
188
235
282
177
236
295
354
472
312
390
468
624
780
582
776
970
696
928
810
1080
1350
1740

95
60
90
120
82
123
164
205
106
159
212
265
318
210
280
350
420
560
435
522
696
520
624
600
720
960
1232

60
25
50
75
34
68
102
136
43
86
129
172
215
114
171
228
285
342
284
355
426
340
425
392
490
588
756

24
0
19
19
0
26
26
52
0
34
34
68
102
45
45
90
135
135
110
165
165
132
198
154
231
231
297

7
0
11
11
0
16
16
16
0
20
20
20
40
27
27
27
54
81
34
68
102
40
80
47
94
141
180

84
66
88
110
90
120
150
180
114
152
190
228
304
200
250
300
400
500
372
496
620
450
600
522
696
870
1110

60
38
57
76
52
78
104
130
66
99
132
165
231
129
172
215
301
344
270
378
432
320
448
375
525
600
768

40
16
32
48
22
44
66
88
29
58
87
116
145
76
114
152
190
228
188
235
282
224
280
264
330
396
504

16
0
13
13
0
18
18
36
0
22
22
44
66
30
30
60
90
90
74
111
111
88
132
102
153
153
198

6
0
9
9
0
13
13
13
0
17
17
17
34
22
22
22
44
66
28
56
84
33
66
38
76
114
147

5
0
0
8
0
0
11
11
0
0
14
14
14
0
18
18
18
36
23
23
46
27
27
32
32
64
82

168
135
180
225
186
248
310
372
237
316
395
474
632
420
525
630
840
1050
780
1040
1300
936
1248
1086
1448
1810
2320

168
135
180
225
186
248
310
372
237
316
395
474
632
420
525
630
840
1050
780
1040
1300
936
1248
1086
1448
1810
2320

Notes:
1. See next page for more Wortez terminal blocks.
2. All quantities shown are for terminal blocks installed in vertical rows.

74
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 75

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

Heat Dissipation
Table

3302 gr

3303 gr

3304 gr

3305 gr

3306 gr

3712 gr Ex

3713 gr Ex

3713/16 gr Ex

3714 gr Ex

3715 gr Ex

3716 gr Ex

30831 gr Ex

30832 gr Ex

30833 gr Ex

30834 gr Ex

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

126
102
136
170
141
188
235
282
177
236
295
354
472
312
390
468
624
780
582
776
970
696
928
810
1080
1350
1740

95
60
90
120
82
123
164
205
106
159
212
265
318
210
280
350
420
560
435
522
696
520
624
600
720
960
1232

60
25
50
75
34
68
102
136
43
86
129
172
215
114
171
228
285
342
284
355
426
340
425
392
490
588
756

24
0
19
19
0
26
26
52
0
34
34
68
102
45
45
90
135
135
110
165
165
132
198
154
231
231
297

7
0
11
11
0
16
16
16
0
20
20
20
40
27
27
27
54
81
33
66
99
40
80
47
94
141
180

84
57
76
95
81
108
135
189
102
136
170
238
306
180
225
315
405
450
392
504
560
462
594
539
693
770
990

60
34
51
68
46
69
92
138
60
90
120
180
210
117
156
234
273
351
294
343
441
348
406
408
476
612
783

36
14
28
42
19
38
57
76
25
50
75
100
125
66
99
132
165
198
164
205
246
196
245
228
285
342
438

14
0
12
12
0
17
17
34
0
21
21
42
63
28
28
56
84
112
70
105
140
84
126
98
147
196
252

6
0
9
9
0
13
13
13
0
17
17
17
34
22
22
22
44
66
28
56
84
33
66
38
76
114
147

5
0
0
8
0
0
11
11
0
0
14
14
14
0
18
18
18
36
23
23
46
27
27
32
32
64
82

98
66
88
110
90
120
150
210
114
152
190
266
342
200
250
350
450
500
434
558
620
525
675
609
783
870
1110

72
38
57
76
52
78
104
156
66
99
132
198
231
129
172
258
301
387
324
378
486
384
448
450
525
675
864

40
16
32
48
22
44
66
88
29
58
87
116
145
76
114
152
190
228
188
235
282
224
280
264
330
396
504

16
0
13
13
0
18
18
36
0
22
22
44
66
30
30
60
90
90
74
111
111
88
132
102
153
153
198

3B–21

TN Series

Manufacturer - Wortez

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

75
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 76

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

MZDB 1,5

MZDB 1,5-NS 35

ZFK 1,5

ZKF 2,5

ZFK 4

ZFK 6

22
0
18
18
0
24
24
48
0
31
31
62
93
41
41
82
123
164
102
153
204
122
183
142
213
284
364

MZB 1,5-NS 35

56
22
44
66
30
60
90
120
39
78
117
156
195
102
153
204
255
357
256
320
448
304
380
356
445
623
798

MZB 1,5

UK 35

80
52
78
104
72
108
144
180
92
138
184
230
322
183
244
305
427
549
380
532
684
455
637
530
742
954
1224

UK 3-RETURN

UK 16 N

140
99
132
165
135
180
225
315
174
232
290
406
464
304
380
532
608
760
665
760
950
791
904
924
1056
1320
1690

MBK 6/E

UK 10 N

189
132
176
220
180
240
300
420
228
304
380
532
608
404
505
707
808
1010
882
1008
1260
1050
1200
1225
1400
1750
2240

MBK 2,5/E-EX

UK 6 N

231
156
208
260
216
288
360
504
273
364
455
637
728
480
600
840
960
1200
1050
1200
1500
1253
1432
1456
1664
2080
2670

UKH 240

UK 5 N

231
156
208
260
216
288
360
504
273
364
455
637
728
480
600
840
960
1200
1050
1200
1500
1253
1432
1456
1664
2080
2670

UKH 150

UK 3 N

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

UKH 95

UK 2,5 N

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

16
6
0
0
13
0
13 10
0
0
18
0
18 15
36 15
0
0
23
0
23 19
46 19
46 38
31
0
31 25
62 25
62 50
93 50
78 31
78 62
117 62
92 37
92 74
108 43
108 86
162 86
207 110

0
0
0
0
0
0
0
0
0
0
0
0
15
0
0
0
20
20
0
25
25
0
30
0
35
35
44

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
17
0
0
21
0
0
0
0
30
38

243
176
220
308
240
300
420
540
304
380
532
684
836
505
707
909
1111
1313
1134
1386
1638
1350
1650
1575
1925
2275
2912

140
99
165
198
135
225
270
315
174
290
348
406
522
380
456
532
684
836
665
855
1045
791
1017
924
1188
1452
1859

198
156
208
260
216
288
360
432
273
364
455
546
728
480
600
720
960
1200
900
1200
1500
1074
1432
1248
1664
2080
2670

264
156
260
312
216
360
432
576
273
455
546
728
910
600
720
960
1200
1440
1200
1500
1800
1432
1790
1664
2080
2496
3204

231
156
208
260
216
288
360
504
273
364
455
637
728
480
600
840
960
1200
1050
1200
1500
1253
1432
1456
1664
2080
2670

128
78
130
156
108
180
216
288
138
230
276
368
460
305
366
488
610
732
600
750
900
720
900
840
1050
1260
1608

112
78
104
130
108
144
180
252
138
184
230
322
368
244
305
427
488
610
525
600
750
630
720
735
840
1050
1340

246
130
195
325
178
267
445
534
226
339
565
678
791
450
750
900
1050
1350
1116
1302
1674
1332
1554
1554
1813
2331
2979

198
104
156
260
144
216
360
432
182
273
455
546
637
360
600
720
840
1080
900
1050
1350
1074
1253
1248
1456
1872
2403

135
88
132
176
120
180
240
300
152
228
304
380
532
303
404
505
707
909
630
882
1134
750
1050
875
1225
1575
2016

100
66
99
132
90
135
180
225
116
174
232
290
348
228
304
380
456
608
475
570
760
565
678
660
792
1056
1352

UKH 50

Heat Dissipation
Table

3B–22

TN Series

Manufacturer - Phoenix

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

76
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 77

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete Enclosure Size, Refer to Catalog Page
3B–24 for Enclosure Prefix and Depth.

1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

1. Using the table below, find the Heat Dissipation Table
Number for the enclosure size you selected.
2. Refer to catalog page 3B–26 for Heat Dissipation Tables.

WKN 35/U

WKN 70/U

WKN 150/U

32
0
27
27
0
37
37
74
0
47
47
94
141
62
62
124
186
186
154
231
231
186
279
216
324
324
414

80
54
81
108
74
111
148
185
94
141
188
235
282
186
248
310
372
496
385
462
616
465
558
540
648
864
1104

42
22
44
66
31
62
93
93
39
78
117
117
195
104
156
156
260
312
192
320
384
231
385
270
450
540
690

20
0
17
17
0
23
23
46
0
29
29
58
58
39
39
78
78
117
96
96
144
116
116
134
134
201
258

7
0
0
11
0
0
15
15
0
0
19
19
38
0
26
26
52
78
32
64
96
38
76
45
90
135
171

6
0
0
0
0
0
0
13
0
0
0
16
16
0
0
22
22
22
27
27
27
33
33
38
38
38
49

3B–23

WKN 16/U

168 126
135 99
180 132
225 165
186 138
248 184
310 230
372 276
237 177
316 236
395 295
474 354
632 472
416 312
520 390
624 468
832 624
1040 780
774 582
1032 776
1290 970
930 696
1240 928
1080 810
1440 1080
1800 1350
2310 1730

WKN 10/U

198
162
216
270
222
296
370
444
282
376
470
564
752
500
625
750
1000
1250
930
1240
1550
1116
1488
1296
1728
2160
2770

WKI 35/U

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

WK 6/U

WK 2.5/U

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

WK 4/U

Heat Dissipation
Table

264-225

264-125

232 160 203 119
138 96 138 81
230 160 184 108
276 192 276 162
189 135 189 111
315 225 252 148
378 270 378 222
504 360 441 259
237 171 237 141
395 285 316 188
474 342 474 282
632 456 553 329
790 570 711 423
525 375 420 252
630 450 630 378
840 600 735 441
1050 750 945 567
1260 900 1155 693
1040 744 910 546
1300 930 1170 702
1560 1116 1430 858
1248 888 1092 651
1560 1110 1404 837
1448 1032 1267 756
1810 1290 1629 972
2172 1548 1991 1188
2784 1992 2552 1529

TN Series

198 140
156 88
208 132
260 176
213 122
284 183
355 244
426 305
270 154
360 231
450 308
540 385
720 539
476 306
595 408
714 510
952 714
1071 816
882 630
1176 882
1323 1008
1056 755
1408 1057
1230 875
1640 1225
1845 1400
2358 1800

264-220

20
15
15
30
21
21
42
42
27
27
54
54
81
36
72
72
108
144
90
135
180
108
162
124
186
248
320

264-120

56
23
46
69
31
62
93
124
39
78
117
156
195
104
156
208
260
312
260
325
390
312
390
360
450
540
696

281-693

285-691

168 140 105 85
88 88 68 54
176 132 102 81
220 176 136 108
122 122 94 74
244 183 141 111
305 244 188 148
366 305 235 185
154 154 118 94
308 231 177 141
385 308 236 188
462 385 295 235
539 539 413 282
408 306 234 189
510 408 312 252
612 510 390 315
714 714 546 378
918 918 624 504
756 630 490 390
882 882 686 468
1134 1134 784 624
906 755 585 465
1057 1057 819 558
1050 875 680 540
1225 1225 952 648
1575 1575 1088 864
2025 2025 1392 1112

280-698

283-691

Manufacturer - Wieland
284-691

198
104
208
260
142
284
355
426
180
360
450
540
630
476
595
714
833
1071
882
1029
1323
1056
1232
1230
1435
1845
2358

282-691

280-991

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3024
3016
3020
3024
3030
3036
3624
3036
3636
4224
4230
4824
4830
4836
6036

281-991

Heat Dissipation
Table

-1224XX
-1612XX
-1616XX
-1620XX
-2012XX
-2016XX
-2020XX
-2024XX
-2412XX
-2416XX
-2420XX
-2424XX
-2430XX
-3016XX
-3020XX
-3024XX
-3030XX
-3036XX
-3624XX
-3630XX
-3636XX
-4224XX
-4230XX
-4824XX
-4830XX
-4836XX
-6036XX

281-691

TN Series

Manufacturer - Wago

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

77
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 78

TN4 Expanded Series - Enclosure Outline

3B–24

ENCLOSURE
SIZE
-1224xx
-1612xx
-1616xx
-1620xx
-2012xx
-2016xx
-2020xx
-2024xx
-2412xx
-2416xx
-2420xx
-2424xx
-301606
-3020xx
-3024xx
-3624xx
-3630xx
-2430xx
-3030xx
-303608
-3636xx
-422408
-4230xx
-4236xx
-482408
-4830xx
-4836xx
-6036xx

H
305
406
406
406
508
508
508
508
610
610
610
610
762
762
762
914
914
610
762
762
914
1067
1067
1067
1219
1219
1219
1524

W
610
305
406
508
305
406
508
610
305
406
508
610
406
508
610
610
762
762
762
914
914
610
762
914
610
762
914
914

06
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
------------

08
203
203
203
203
203
203
203
203
203
203
203
203
-203
203
203
203
203
203
203
203
203
203
203
203
203
203
203

10
-254
---254
254
-254
-254
254
-254
254
254
254
-----254
254
-254
254
254

D
12
-----305
----305
305
--305
305
305
-305
-305
-305
305
--305
305

16
----------406
406
--406
-406
------406
--406
406

20
--------------508
-508
---------508
508

24
--------------588
------------588

M

N

S

T

359
460
460
460
562
562
562
562
664
664
664
664
816
816
816
968
968
664
816
816
968
1121
1121
1121
1273
1273
1273
1578

458
241
254
356
241
254
356
458
241
254
356
458
254
356
458
458
610
610
610
762
762
458
610
762
458
610
762
762

229
330
330
330
432
432
432
432
534
534
534
534
686
686
686
838
838
534
686
686
838
991
991
991
1143
1143
1143
1448

534
229
330
432
229
330
432
534
229
330
432
534
330
432
534
534
686
686
686
838
838
534
686
838
534
686
838
838

# OF
CLAMPS
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
7
7
7
7
7
6
8
8
6
8
8
9

STIFFENER
BOX COVER
----------------------------------------------------------------REQ'D REQ'D
----REQ'D REQ'D
REQ'D REQ'D
REQ'D REQ'D
--REQ'D
REQ'D REQ'D
REQ'D REQ'D
--REQ'D
REQ'D REQ'D
REQ'D REQ'D
REQ'D REQ'D

NOTES:
1. Dimensions in table are Metric.
2. xx in Enclosure Size indicates multiple depths. Complete Enclosure Size with depths indicated in Column D (i.e. 122408).
78
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 79

TN4 Expanded Series - Catalog Numbers

TN4X6-122408
TN4X6-161208
TN4X6-161608
TN4X6-162008
TN4X6-201208
TN4X6-201608
TN4X6-202008
TN4X6-202408
TN4X6-241208
TN4X6-241608
TN4X6-242008
TN4X6-242408
TN4X6-302008
TN4X6-302408
TN4X6-362408
TN4X6-363008
TN4X6-243008
TN4X6-303008
TN4X6-303608
TN4X6-363608
TN4X6-422408
TN4X6-423008
TN4X6-423608
TN4X6-482408
TN4X6-483008
TN4X6-483608
TN4X6-603608

1224
1612
1616
1620
2012
2016
2020
2024
1224
2416
2024
2424
3020
3024
3624
3036
3024
3030
3036
3636
4224
4230
4236
4824
4830
4836
6036

SS316L Enclosures with Terminals
Catalog Numbers Heat Dissipation
Table
TN4X6-161210
1612
TN4X6-201610
2016
TN4X6-202010
2020
TN4X6-241210
2412
TN4X6-242010
2024
TN4X6-242410
2424
TN4X6-302010
3020
TN4X6-302410
3024
TN4X6-362410
3624
TN4X6-363010
3036
TN4X6-483010
4830
TN4X6-483610
4836
TN4X6-603610
6036

TN4X6-201612
TN4X6-242012
TN4X6-242412
TN4X6-302412
TN4X6-362412
TN4X6-363012
TN4X6-303012
TN4X6-363612
TN4X6-423012
TN4X6-423612
TN4X6-483612
TN4X6-603612

2016
2024
2424
3024
3624
3036
3030
3636
4230
4236
4836
6036

TN4X6-242016
TN4X6-242416
TN4X6-302416
TN4X6-363016
TN4X6-423616
TN4X6-483616
TN4X6-603616

2024
2424
3024
3036
4236
4836
6036

Mounting Pans
Enclosure Size
Catalog
Numbers
-1224xx
V2412
-1612xx
V1612
-1616xx
V1616
-1620xx
V1620
-2012xx
V2012
-2016xx
V2016
-2020xx
V2020
-2024xx
V2420
-2412xx
V2412
-2416xx
V2416
-2420xx
V2420
-2424xx
V2424
-3020xx
V3020
-3024xx
V3024
-3624xx
V3624
-3630xx
-2430xx
-3030xx
-3036xx
-3636xx
-4224xx
-4230xx
-4236xx
-4824xx
-4830xx
-4836xx
-6036xx

V3630
V3024
V3030
V3036
V3636
V4224
V4230
V4236
V4824
V4830
V4836
V6036

3B–25

SS316L Enclosures with Terminals
Catalog Numbers Heat Dissipation
Table
TN4X6-122406
1224
TN4X6-161206
1612
TN4X6-161606
1616
TN4X6-162006
1620
TN4X6-201206
2012
TN4X6-201606
2016
TN4X6-202006
2020
TN4X6-202406
2024
TN4X6-241206
2412
TN4X6-241606
2416
TN4X6-242006
2024
TN4X6-242406
2424
TN4X6-301606
3016
TN4X6-302006
3020
TN4X6-302406
3024
TN4X6-362406
3624
TN4X6-363006
3036

NOTES:
1. For Stainless Steel 304 assemblies
substitute TN4X6 prefix with TN4X.
2. For Steel Powder Coated assemblies
substitute TN4X6 prefix with TN4.
3. For Empty Enclosures add U
immediately following enclosure size
(i.e. TN4X6-122406U).
4. For Stainless Steel Mounting Pan add
S to catalog number (i.e. V2412S).

TN4X6-302420
TN4X6-363020
TN4X6-483620
TN4X6-603620

3024
3036
4836
6036

TN4X6-483624
TN4X6-603624

4836
6036

5. For Aluminum Mounting Pan add A to
catalog number (i.e. V2412A).
6. For Increased Safety Applications,
refer to Heat Dissipation Tables
indicated next to Catalog number.

79
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 80

Heat Dissipation Tables
Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to the terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found.
5. If neither is possible, continue to the next size enclosure until the desired terminal count is found.

3B–26

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400

1224 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
95
46
15
30
119
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
6
18
34
8
19
37
5
14
36
2
12
30
4
14
50
5
15
56
6
14
6
15
5
13
4
11
35
Additional Testing Required,
Consult Factory
1
6
13
3
8
1

150

17
5

185

10
2

1612 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(Amps)
1.5
2.5
4
6
10
16
25
35
50
70
95
8
90
10
44
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
16
15
29
113
20
6
17
33
25
8
18
36
35
5
14
35
50
2
11
29
63
3
13
47
80
5
15
53
100
6
14
125
5
14
160
4
12
200
4
10
Additional Testing Required,
Consult Factory
225
1
6
250
3
1616 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(Amps)
1.5
2.5
4
6
10
16
25
35
50
70
95
8
100
10
48
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
16
16
32
125
20
7
19
36
25
9
20
39
35
6
15
38
50
2
12
32
63
4
14
52
80
5
16
59
100
7
15
125
6
15
160
5
14
200
5
12
Additional Testing Required,
Consult Factory
225
1
7
250
3

Notes:
1. See the end of this section for applications using multiple terminal blocks.

80
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 81

Heat Dissipation Tables
1620 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
106
51
17
34
133
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
7
20
38
9
22
24
6
16
41
2
13
34
4
15
56
6
17
62
7
16
6
16
5
14
5
12
39
Additional Testing Required,
Consult Factory
2
7
15
3
9
2

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315

2012 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
93
45
15
30
117
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
6
17
34
8
19
37
5
14
36
2
11
29
4
13
49
5
15
55
6
14
5
14
5
13
4
11
34
Additional Testing Required,
Consult Factory
1
6
13
3
8
1

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315

2016 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
106
51
17
34
133
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
7
20
38
9
22
42
6
16
41
2
13
34
4
15
56
6
17
62
7
16
6
16
5
14
5
12
39
Additional Testing Required,
Consult Factory
2
7
15
3
9
2

Qualifying Enclosure for Increased
Safety Certification
150

1. Find the Wire Size (conductor) you intend
to use to connect to the terminal block.
2. Find the Current (amperage) you intend to
apply to the conductor.
3. The intersection of the Wire Size (column)
and Current (row) gives you the maximum
number of terminal blocks permitted
for proper heat dissipation and Increased
Safety Certification.
4. If the terminal count is too small, decrease
the current or increase the wire size until
the desired terminal count is found.

19
5

5. If neither is possible, continue to the next
size enclosure until the desired terminal
count is found.

150

3B–27

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315

17
5

150

Notes:
19
5

1. See the end of this section for applications
using multiple terminal blocks.

81
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 82

Heat Dissipation Tables
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315

3B–28

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400

2020 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
115
66
19
37
144
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
8
22
42
10
23
45
7
18
44
2
14
36
4
17
60
6
19
67
8
18
7
18
6
16
5
13
42
Additional Testing Required,
Consult Factory
2
8
16
4
10
2

2024 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
121
59
20
39
152
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
8
23
44
10
25
48
7
18
46
2
15
38
5
18
64
7
20
71
8
18
7
19
6
16
6
14
45
Additional Testing Required,
Consult Factory
2
8
17
4
10
2

2412 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
95
46
15
30
119
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
6
18
34
8

19
5

37
14
2

36
12
4

Additional Testing Required,
Consult Factory

30
14
5

50
15
6

56
14
6

15
5

13
4
1

11
6
3

35
13
8
1

Qualifying Enclosure for Increased
Safety Certification
150

1. Find the Wire Size (conductor) you intend
to use to connect to the terminal block.
2. Find the Current (amperage) you intend to
apply to the conductor.
3. The intersection of the Wire Size (column)
and Current (row) gives you the maximum
number of terminal blocks permitted
for proper heat dissipation and Increased
Safety Certification.
4. If the terminal count is too small, decrease
the current or increase the wire size until
the desired terminal count is found.
5. If neither is possible, continue to the next
size enclosure until the desired terminal
count is found.

21
6

150

22
12

150

185

13
3

185

Notes:
17
5

10
2

1. See the end of this section for applications
using multiple terminal blocks.

82
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 83

Heat Dissipation Tables

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

2416 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
110
53
18
35
138
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
7
20
40
9
22
43
6
17
42
2
13
35
4
16
58
6
18
64
7
17
6
17
6
15
5
13
40
Additional Testing Required,
Consult Factory
2
7
16
4
9
2

2424 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
1.5
2.5
4
6
10
16
25
35
50
70
95
120
130
63
21
42
113
Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
9
24
47
11
26
51
7
20
50
3
16
41
5
19
68
7
21
76
9
20
1
8
20
7
18
6
15
48
Additional Testing Required,
Consult Factory
2
9
19
4
11
2

1.5
139
67
23
9

Qualifying Enclosure for Increased
Safety Certification
150

174
50
28
8

1. Find the Wire Size (conductor) you intend
to use to connect to the terminal block.
2. Find the Current (amperage) you intend to
apply to the conductor.
3. The intersection of the Wire Size (column)
and Current (row) gives you the maximum
number of terminal blocks permitted
for proper heat dissipation and Increased
Safety Certification.
4. If the terminal count is too small, decrease
the current or increase the wire size until
the desired terminal count is found.

20
5

150

24
7

2430 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

45
51
12

185

12
2

5. If neither is possible, continue to the next
size enclosure until the desired terminal
count is found.

185

3B–29

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400

14
3

185

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
55
21
3

53
17
6

Additional Testing Required,
Consult Factory

44
20
8

73
23
9
1

82
21
8

22
7

19
7
2

16
9
5

51
20
12
2

25
7

Notes:
15
3

10
1

1. See the end of this section for
applications using multiple
terminal blocks.
83

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 84

Heat Dissipation Tables
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

3B–30

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
113
55
18
7

3016 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

36
21
10

142
41
23
6

160
46
26

45
17
2

43
14
4

36
16
6

59
18
8

66
17
7

17
6

3. The intersection of the Wire Size
(column) and Current (row) gives
you the maximum number of
terminal blocks permitted
for proper heat dissipation and
Increased Safety Certification.
15
5
2

13
7
4

42
16
10
2

20
6

50
19
2

49
16
5

40
19
7

67
21
9

75
19
8

20
7

17
6
2

15
8
4

47
18
11
2

23
6

3024 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

45
26
12

174
50
28
8

1. Find the Wire Size (conductor)
you intend to use to connect to
the terminal block.

12
2

185

4. If the terminal count is too small,
decrease the current or increase
the wire size until the desired
terminal count is found.
8
1

5. If neither is possible, continue to
the next size enclosure until the
desired terminal count is found.

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
139
67
23
9

240

2. Find the Current (amperage) you
intend to apply to the conductor.

3020 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

41
24
11

185

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
127
62
21
8

Qualifying Enclosure for Increased
Safety Certification

14
3

185

9
1

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
55
21
3

53
17
6

Additional Testing Required,
Consult Factory

44
20
8

73
23
9

82
21
8

22
7

19
7
2

16
9
5

51
20
12
2

25
7

Notes:
15
3

10
1

1. See the end of this section for
applications using multiple
terminal blocks.

84
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 85

Heat Dissipation Tables

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
152
74
25
10

3030 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

49
28
13

191
55
31
9

203
59
33
9

60
23
3

58
19
6

48
22
8

80
25
10
1

89
23
9

24
8

3. The intersection of the Wire Size
(column) and Current (row) gives
you the maximum number of
terminal blocks permitted
for proper heat dissipation and
Increased Safety Certification.
21
7
2

18
10
5

56
22
13
2

28
8

64
25
3

62
20
7

51
24
9

85
26
11
1

95
25
10

25
8

22
8
3

19
11
12

60
23
14
3

30
8

3624 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

46
27
13

182
52
30
8

1. Find the Wire Size (conductor)
you intend to use to connect to
the terminal block.

16
3

185

4. If the terminal count is too small,
decrease the current or increase
the wire size until the desired
terminal count is found.
11
1

5. If neither is possible, continue to
the next size enclosure until the
desired terminal count is found.

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
145
70
24
10

240

2. Find the Current (amperage) you
intend to apply to the conductor.

3036 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

52
30
14

185

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
162
78
27
11

Qualifying Enclosure for Increased
Safety Certification

3B–31

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

18
4

185

12
1

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
57
22
3

56
18
6

Additional Testing Required,
Consult Factory

46
21
8

76
24
10

85
22
9

22
7

20
7
2

17
10
5

53
21
12
2

26
7

Notes:
16
3

11
1

1. See the end of this section for
applications using multiple
terminal blocks.
85

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 86

Heat Dissipation Tables
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

3B–32

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
175
85
29
12

3636 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

56
33
15

219
63
36
10

187
54
30
9

69
27
4

67
22
7

56
56
10

92
28
12
1

103
27
11

27
9

3. The intersection of the Wire Size
(column) and Current (row) gives
you the maximum number of
terminal blocks permitted
for proper heat dissipation and
Increased Safety Certification.
24
8
3

21
12
6

64
25
15
3

23
9

59
23
3

57
18
6

47
22
8

78
24
10
1

87
23
9

23
8

20
7
2

18
10
5

55
22
13
2

27
8

4230 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

54
31
15

211
61
34
10

1. Find the Wire Size (conductor)
you intend to use to connect to
the terminal block.

19
4

185

4. If the terminal count is too small,
decrease the current or increase
the wire size until the desired
terminal count is found.
13
1

5. If neither is possible, continue to
the next size enclosure until the
desired terminal count is found.

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
168
82
28
11

240

2. Find the Current (amperage) you
intend to apply to the conductor.

4224 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

48
28
13

185

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
149
72
24
10

Qualifying Enclosure for Increased
Safety Certification

16
3

185

11
1

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
67
26
3

65
21
7

Additional Testing Required,
Consult Factory

54
25
9

88
27
12
1

99
26
10

26
9

23
8
3

20
11
6

62
24
15
3

31
9

Notes:
18
4

12
1

1. See the end of this section for
applications using multiple
terminal blocks.

86
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 87

Heat Dissipation Tables

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
184
89
30
12

4236 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

59
34
16

231
67
38
11

73
28
4

190
55
31
9

71
23
7

59
27
10

97
30
13

108
28
11

29
10

3. The intersection of the Wire Size
(column) and Current (row) gives
you the maximum number of
terminal blocks permitted
for proper heat dissipation and
Increased Safety Certification.
25
9
3

22
12
6

68
26
16
3

34
9

60
43
3

58
19
6

48
22
8

79
25
10
1

89
23
9

24
8

21
7
2

18
10
5

56
22
13
2

28
8

4830 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

56
32
15

217
63
35
10

1. Find the Wire Size (conductor)
you intend to use to connect to
the terminal block.

20
4

185

4. If the terminal count is too small,
decrease the current or increase
the wire size until the desired
terminal count is found.
14
2

5. If neither is possible, continue to
the next size enclosure until the
desired terminal count is found.

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
173
84
29
12

240

2. Find the Current (amperage) you
intend to apply to the conductor.

4824 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

49
28
13

185

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
151
73
25
10

Qualifying Enclosure for Increased
Safety Certification

3B–33

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

16
3

185

11
1

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
69
27
4

67
22
7

Additional Testing Required,
Consult Factory

55
25
10

91
28
12
1

102
27
11

27
9

24
8
3

21
12
6

64
25
15
3

32
9

Notes:
19
4

13
1

1. See the end of this section for
applications using multiple
terminal blocks.
87

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 88

Heat Dissipation Tables
Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

3B–34

Current
(Amps)
8
10
16
20
25
35
50
63
80
100
125
160
200
225
250
315
400
500

1.5
192
93
32
13

4836 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

62
36
17

240
70
39
11

76
30
4

74
24
8

61
28
11

101
31
13

113
30
12

30
10

26
9
3

23
13
7

71
28
17
3

35
10

6036 - Terminal Block Population for Increased Safety Heat Dissipation Requirements
Maximum Terminal Block Wire Size (mm2)
2.5
4
6
10
16
25
35
50
70
95
120
150

65
38
18

253
73
41
12

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances

Additional Testing Required,
Consult Factory

1.5
202
98
33
14

185

21
4

185

14
2

240

Maximum fill permitted based solely on minimum
wire bending space and electrical clearances
80
31
4

78
25
8

64
30
11

106
33
14
1

Additional Testing Required,
Consult Factory

119
32
12

32
11

28
10
3

24
14
7

75
29
18
3

37
10

22
10

15
2

Notes:
1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor
size and the continuous current for the designated enclosures.
2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and
manufacturer's instructions.
3. Grounding terminals, bridges and grounding conductors are not counted.
4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges.
5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals and
conductors should be considered.
6. Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below.
Example from Conductor Size
-6036xx Table:

Current

Number

% of Maximum Terminal Population

2.5

16

35 (of 65)

=

54%

4

20

15 (of 73)

=

21%

10

35

19 (of 78)

=

24%

Total

=

99%

<

100%

7. Combinations not covered by the above tables may be permitted if they are determined acceptable by test.
88
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 89

Conduit/Cable & Wire Bending Guidelines
Table A - Minimum Spacing Between Centers of Conduit or Cable Entries
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

NPT

METRIC

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

1/16 ~ 3/8

--

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

1-1/8
[29mm]

1/2

M16

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

3/4

M20

4-1/2
[115mm]

3-3/4
[96mm]

3-1/2
3-1/8
[89mm] [80mm]

2-3/4
[70mm]

2-1/2
[64mm]

2-1/8
[54mm]

2
[51mm]

1-3/4
[45mm]

1-1/2
[38mm]

1

M25

4-5/8
[118mm]

3-7/8
[99mm]

3-5/8
3-1/4
[92mm] [83mm]

2-7/8
[74mm]

2-3/4
[70mm]

2-1/4
[58mm]

2-1/8
[54mm]

1-7/8
[48mm]

1-1/4

M32

4-7/8
[124mm]

4-1/8
[105mm]

3-7/8
[99mm

3-1/2
[89mm]

3-1/8
[80mm]

2-7/8
[74mm]

2-1/2
[64mm]

2-3/8
[61mm]

1-1/2

M40

5
[127mm]

4-1/4
4
3-5/8
[108mm] [102mm] [92mm]

3-1/4
[83mm]

3
[77mm]

2-5/8
[68mm]

2

M50

5-3/8
[137mm]

4-3/4
4-1/2
4
3-5/8
[121mm] [115mm] [102mm] [92mm]

3-3/8
[86mm]

2-1/2

M63

5-1/2
[140mm]

4-7/8
4-5/8
4-1/4
3-7/8
[124mm] [118mm] [108mm] [99mm]

3

M75

5-7/8
[150mm]

5-1/4
5
4-5/8
[134mm] [127mm] [118mm]

3-1/2

--

6-1/4
[159mm]

5-3/4
5-1/2
[147mm] [140mm]

4

--

6-7/8
[175mm]

6
[153mm]

5

--

7-3/8
[188mm]

3B–35

SIZE

This information is compiled from data which we believe is
reliable and is given in good faith. Since the methods of
application and condition under which our products are used are
beyond our control, we are not able to guarantee the application
and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

2-13/16
[72mm]

2-1/4
[58mm]

2
[51mm]

1-3/16
[31mm]

1
[26mm]

7/8
[23mm]

11/16
[18mm]

9/16
[14mm]

1/2
[13mm]

1/2
[13mm]

METRIC

1-3/4
1-7/16
[45mm] [37mm]

Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls
AWG

16

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

250

350

400

500

mm sq.

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

1-1/2
1-1/2 1-1/2 1-1/2
2
3
3-1/2
5-1/2
6
6-1/2
7
8-1/2
10
12
13
14
[38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm]
Notes:
1. The distances in Table A are recommended minimum
distances between centers of conduit and cable gland
entries. Consult manufacturer of conduit fitting or cable
glands for their recommended minimum spacing.

entries to the edge of an opening or inside wall of box.
Consult manufacturer of conduit fitting or cable glands for
their recommended minimum spacing.
3. The distances in Table C are the minimum wire bending
space requirements between terminals, partitions, or inside
walls.

2. The distances in Table B are recommended minimum
distances between center of conduit and cable gland

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

89

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 90

TSC Series - Screw Cover Terminal Enclosure
EMC Shielding
For stainless steel enclosures only
EMC shielding is available on the TSC4X (SS304) and TSC4X6
(SS316L) enclosures with a shielding effectiveness of >50dB
through out the frequency range of 1MHz to 1000MHz. For EMC
shielding add the prefix -EMC to the catalog text string,
immediately following the enclosure size. (i.e. TSC4X-101006-EMC)
Note: This option is not available on enclosures with gland plates
installed.

TSC Shielding Effectiveness

90

Attenuation in dB

80
70
60
50
40
30
20

18 Enclosure Sizes

1000

900

800

700

600

500

400

300

200

90

100

80

70

60

50

40

30

10

0

Available in 18 sizes, from 5”x5”x3” (model 050503) to
16”x16”x8” (model 161608).

20

10

Frequency (Mhz)

3B–36

Conduit/Cable Entries:
Entries can be provided per a customer sketch or with detailed
information on the entry locations. Please refer to Entry Spacing
Tables at the end of the Increased Safety Section in the CENELEC
Product Catalog. Note: This information is important and could
affect the size of the enclosure you selected.

Construction
• Available in (3) Materials: SS304, SS316L, PowderCoated (ASA61 Grey) Steel.
• Continuously Welded and Ground Smooth Seams.
• Continuous One-Piece Silicone Gasket.
• Welded on External Mounting Feet with 5/16”
Clearance Holes.

Close-up Plugs:
Any unused entries must be plugged with a Certified Close-Up
Plug. Adalet can provide close-up plugs in various styles and
materials. Please indicate on the sketch or provide detailed
information of holes to be plugged.

• Captive Cover Screws.
• Universal Rail Mounting System.
(Mounting pan supplied standard on 050503 enclosure).

Enclosure Labeling:
Adalet can provide additional enclosure labeling with custom silk
screening or various colors of Lamacoid™ nameplates. Please
provide detailed information of the logo or text required.

• Ground Studs on Box and Cover.
• Internal/External Earthing Stud.

Options

Breather Drains:
Breather Drains can be provided per customer request. They are
available in Brass or Stainless Steel 316L. Please indicate on a
sketch or provide detailed information for locations.

Gland Plates
For enclosures with depths greater than 6”
These removable plates offer great flexibility for the end
user to drill holes without having to remove the entire
enclosure from the installation site.

Grounding Busbars:
Some applications might require grounding points to be terminated
in the enclosure. With the use of a Ground Busbar System this can
be accomplished, consult factory for options.

Add the following Suffixes:
-A: Gland Plate installed on top of box.
-B: Gland Plate installed on bottom of box.
-C: Gland Plate installed on left of box.
-D: Gland Plate installed on right of box.
For multiple gland plates omit dashes
(i.e. TSC4X-101006-ABCD)

Mounting Pans:
As an alternative to the universal rail mounting system, mounting
pans are available in steel/powder coated, stainless steel, and
aluminum. Please indicate when requesting quote.
Terminal Strip Assemblies:
Various options (i.e. marking tags, protective covers, jumpers,
partitions,..) are available. Please provide detailed information
requesting quote.

90
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 91

TSC Series - Screw Cover Terminal Enclosure
General Information
Adalet's Screw Cover Terminal Enclosures are available in
Stainless Steel 304 & 316 and Carbon Steel. Adalet can also
supply custom size enclosures, operators, and components to
suit your EEx e application. Silicone gasket, slotted captive cover
bolts, box & cover ground studs including an internal/external
earthing stud, and universal rail mounting system are included as
standard (except 050503, mtg. pan used).

0539
II 2GD
EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Empty Enclosure Certifications
0539
II 2GD
EEx e II
Ex e II
Class I, Zone 1, AEx e II
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Working Voltage
Terminal Blocks
Various manufacturers
Material
TSC4 Series
TSC4X Series
TSC4X6 Series
TSC4 Series Gland Plates
TSC4X Series Gland Plates
TSC4X6 Series Gland Plates
Mounting Pan
Gasket
Cover
Gland Plates
Lid Fixing
All Types
Enclosure Mounting
All Types
Gland Plate Hardware
All Types
Grounding
Box & Cover
All Types
Earthing Stud
All Types
Impact Resistant
All Types
Ambient Temperature Range
All Types

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50

3B–37

Enclosure Certifications with Terminals

D

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50
1100 Volts Maximum
EEx e type with wire sizes 1.5mm up to 16mm
#14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray
#14ga Stainless Steel 304, Brushed Finish
#14ga Stainless Steel 316, Brushed Finish
#10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray
#10ga Stainless Steel 304, Brushed Finish
#10ga Stainless Steel 316, Brushed Finish
#14ga Cold Rolled Steel, Polyster Powder Coated White
Silicone Sponge
Silicone Sponge
1/4-20 Captive Slotted Hex Head Bolts - Stainless Steel
External mounting feet with .31'' clearance holes
300 Series stainless steel
1/4-20 Stud with 300 series stainless steel hardware
1/4-20 Stud - All components brass
7 Nm to EN50014/EN50019
-40°C to +70°C to EN50014

D

91
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 92

TSC Series - Quick Selector
4. To complete Catalog Number, Refer to Catalog Page
indicated next to enclosure size.

Enclosure Selection
1. Using the table below, select the terminal block size
for your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications
1. Using the table below, refer to the Heat Dissipation Table
found on the catalog page for the enclosure size you
selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

Maximum Physical Terminal Block Content

TN4 Series

3B–38

Enclosure

Catalog

Sizes

Page

-050503

3B–47

8

-060604

3B–48

13

-070704

3B–49

18

-080804

3B–50

-101006
-101008

1.5mm

2.5mm

4mm

6mm

10mm 16mm

35mm

50mm 70mm 95mm 120mm 150mm 185mm 240mm

6

6

5

0

0

0

0

0

0

0

0

0

0

11

10

8

6

0

0

0

0

0

0

0

0

0

15

14

11

9

0

0

0

0

0

0

0

0

0

46

19

17

28

11

9

0

0

0

0

0

0

0

0

3B–51

66

54

50

40

32

14

0

0

0

0

0

0

0

0

3B–52

66

54

50

40

32

14

0

0

0

0

0

0

0

0

-120604

3B–53

43

36

33

27

21

0

0

0

0

0

0

0

0

0

-120605

3B–54

43

36

33

27

21

0

0

0

0

0

0

0

0

0

-120805

3B–55

86

36

33

54

21

18

0

0

0

0

0

0

0

0

-120806

3B–56

86

36

33

54

21

18

0

0

0

0

0

0

0

0

-121206

3B–57

129

108

99

81

42

18

0

0

0

0

0

0

0

0

-121208

3B–58

129

108

99

81

42

18

0

0

0

0

0

0

0

0

-151506

3B–59

236

192

176

144

87

48

18

14

0

0

0

0

0

0

-151508

3B–60

236

192

176

144

87

48

18

14

0

0

0

0

0

0

-161206

3B–61

192

156

144

117

64

26

0

0

0

0

0

0

0

0

-161208

3B–62

192

156

144

117

64

26

0

0

0

0

0

0

0

0

-161606

3B–63

256

208

192

156

96

52

20

16

14

0

0

0

0

0

-161608

3B–64

256

208

192

156

96

52

20

16

14

0

0

0

0

0

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.
2. Quantities shown above are for Adalet supplied standard terminal blocks.

92
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 93

Maximum Physical Terminal Block Content

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size.

Enclosure Selection
1. Using the table below, select the terminal block type for
your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications
1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure Size
column. This is the minimum enclosure size (H X W)
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

M6/8…

M10/10…

M16/12…

M35/16…

M4/6.H…

M1,5/6.HH

MTC6

MA2,5/5.SN

M4/6.SN…

M4/6.SNB

7
12
17
44
64
64
42
42
84
84
126
126
228
228
186
186
248
248

7
12
17
44
64
64
42
42
84
84
126
126
228
228
186
186
248
248

6
10
14
38
54
54
35
35
70
70
105
105
192
192
156
156
208
208

4
8
11
28
40
40
27
27
54
54
81
81
144
144
117
117
156
156

0
6
9
11
32
32
21
21
21
21
42
42
87
87
62
62
93
93

0
0
0
9
13
13
0
0
18
18
18
18
48
48
26
26
52
52

0
0
0
0
0
0
0
0
0
0
0
0
18
18
0
0
19
19

0
10
14
19
54
54
35
35
35
35
70
70
144
144
104
104
208
208

0
10
14
19
54
54
35
35
35
35
70
70
144
144
104
104
156
156

6
10
14
38
54
54
35
35
70
70
105
105
192
192
156
156
208
208

7
12
17
44
64
64
42
42
84
84
126
126
228
228
186
186
248
248

6
10
14
38
54
54
35
35
70
70
105
105
192
192
156
156
208
208

6
10
14
38
54
54
35
35
70
70
105
105
192
192
156
156
208
208

3B–39

M4/6…

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

MA2,5/5.1…

Cat. Page

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

MA2,5/5…

Enclosure
Size

Manufacturer - Entrelec

Notes:
1. See next page for more Entrelec terminal blocks.
2. All quantities shown are for terminal blocks installed in vertical rows.

93
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 94

Maximum Physical Terminal Block Content

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications
1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
(H X W) for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

M35/26.FF

M70/31.FF

M35/26.AF

M70.31.AF

D4/6…ADO

D4/6.ADO.T…

D4/6.ADO…

0
8
11
14
40
40
27
27
27
27
54
54
108
108
78
78
117
117

7
11
30
40
84
84
36
36
72
72
144
144
245
245
212
212
265
265

0
0
0
0
6
6
0
0
0
0
8
8
11
11
12
12
12
12

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10
10

0
0
0
0
6
6
0
0
0
0
8
8
11
11
12
12
12
12

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10
10

6
10
14
19
54
54
35
35
35
35
105
105
192
192
156
156
208
208

6
10
14
19
54
54
35
35
35
35
105
105
192
192
156
156
208
208

6
10
14
19
54
54
35
35
35
35
105
105
192
192
156
156
208
208

4
8
11
14
40
40
27
27
27
27
81
81
144
144
117
117
156
156

D6/8.ADO…

DR4/6…

4
8
11
28
40
40
27
27
54
54
81
81
144
144
117
117
156
156

D6/8…ADO

M4/8.SN

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

M6/8.SNB

3B–40

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

Cat. Page

Enclosure
Size

Manufacturer - Entrelec

4
8
11
14
40
40
27
27
27
27
81
81
144
144
117
117
156
156

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

94
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 95

Maximum Physical Terminal Block Content

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

Cat. Page

WDU2.5N

WDU2.5

WDU4

WDU6

WDU10

WDU16

WDU35

WWF35

ZDU2.5

ZDU4

ZDU6

AKZ2.5

AKZ4

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

8
13
18
46
66
66
43
43
86
86
129
129
236
236
192
192
256
256

0
13
18
23
66
66
43
43
43
43
86
86
177
177
128
128
192
192

0
13
18
23
66
66
43
43
43
43
86
86
177
177
128
128
192
192

0
8
11
14
42
42
27
27
27
27
54
54
111
111
80
80
120
120

0
0
9
11
17
17
0
0
22
22
44
44
58
58
64
64
96
96

0
0
0
0
14
14
0
0
0
0
18
18
48
48
26
26
52
52

0
0
0
0
0
0
0
0
0
0
0
0
18
18
0
0
20
20

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
11

0
13
18
23
66
66
43
43
43
43
86
86
174
174
126
126
189
189

0
11
15
19
54
54
36
36
36
36
72
72
144
144
104
104
156
156

0
8
11
14
40
40
27
27
27
27
54
54
108
108
78
78
117
117

7
12
34
46
99
99
43
43
86
86
172
172
290
290
252
252
315
315

6
10
28
36
81
81
35
35
70
70
140
140
240
240
208
208
260
260

3B–41

Enclosure Size

Manufacturer - Weidmuller

Notes:
1. See next page for more Weidmuller terminal blocks.
2. All quantities shown are for terminal blocks installed in vertical rows.

95
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 96

Maximum Physical Terminal Block Content

4. To complete Catalog Number, Refer to Catalog Page
indicated next to the enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

Cat. Page

AKE2.5

AKE4

SAK2.5

SAK4

SAK6N

SAK10

SAK16

SAK35N

SAK70

SAKG 28 I

SAKG 28 II

SAKG 28 III

3B–42

Enclosure Size

Manufacturer - Weidmuller

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

7
12
34
46
99
99
43
43
86
86
172
172
290
290
252
252
315
315

6
9
13
34
72
72
31
31
62
62
93
93
172
172
138
138
230
230

6
11
15
19
54
54
36
36
36
36
108
108
192
192
156
156
208
208

6
10
14
17
50
50
33
33
33
33
99
99
176
176
144
144
192
192

5
8
11
28
40
40
27
27
54
54
81
81
144
144
117
117
156
156

0
6
9
11
32
32
21
21
21
21
42
42
87
87
64
64
96
96

0
0
0
9
14
14
0
0
18
18
18
18
48
48
26
26
52
52

0
0
0
0
0
0
0
0
0
0
0
0
18
18
0
0
20
20

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
14
14

0
0
0
0
0
0
0
0
0
0
0
0
9
9
0
0
10
10

0
0
0
0
0
0
0
0
0
0
0
0
9
9
0
0
10
10

0
0
0
0
0
0
0
0
0
0
0
0
9
9
0
0
10
10

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

96
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 97

Maximum Physical Terminal Block Content

4. To complete Catalog Number, Refer to Catalog Page
indicated next to the enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

Cat. Page

30128 gr

3424 gr

3425 gr

3426 gr

3427 gr

3428 gr

3429 gr

30841 gr Ex

30842 gr Ex

30843 gr Ex

30844 gr Ex

3468 gr Ex

30111 gr

3301 gr

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

7
11
15
19
56
56
36
36
36
36
108
108
196
196
159
159
212
212

7
11
15
19
56
56
36
36
36
36
108
108
147
147
159
159
212
212

5
8
11
14
42
42
27
27
27
27
81
81
111
111
120
120
160
160

0
0
10
13
18
18
0
0
24
24
48
48
99
99
70
70
105
105

0
0
0
0
15
15
0
0
0
0
20
20
54
54
29
29
58
58

0
0
0
0
0
0
0
0
0
0
0
0
21
21
0
0
23
23

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
14
14

3
5
7
9
26
26
17
17
17
17
51
51
92
92
75
75
100
100

0
4
6
8
22
22
15
15
15
15
30
30
60
60
44
44
66
66

0
0
0
7
10
10
0
0
13
13
13
13
36
36
19
19
38
38

0
0
0
0
0
0
0
0
0
0
0
0
14
14
0
0
15
15

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
11

7
11
15
19
56
56
36
36
36
36
108
108
196
196
159
159
212
212

7
11
15
19
56
56
36
36
36
36
108
108
147
147
159
159
212
212

3B–43

Enclosure Size

Manufacturer - Woretz

Notes:
1. See next page for more Woretz terminal blocks.
2. All quantities shown are for terminal blocks installed in vertical rows.

97
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 98

Maximum Physical Terminal Block Content

4. To complete Catalog Number, Refer to Catalog Page
indicated next to the enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

Cat. Page

3302 gr

3303 gr

3304 gr

3305 gr

3306 gr

3712 gr Ex

3713 gr Ex

3713/16 gr Ex

3714 gr Ex

3715 gr Ex

30831 gr Ex

30832 gr Ex

30833 gr Ex

30834 gr Ex

3B–44

Enclosure Size

Manufacturer - Woretz

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

5
8
11
14
42
42
27
27
27
27
81
81
111
111
120
120
160
160

0
0
10
13
18
18
0
0
24
24
48
48
99
99
70
70
105
105

0
0
0
0
15
15
0
0
0
0
20
20
54
54
29
29
58
58

0
0
0
0
0
0
0
0
0
0
0
0
21
21
0
0
23
23

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13
13

3
5
6
16
24
24
15
15
30
30
45
45
84
84
69
69
92
92

0
4
6
7
20
20
13
13
13
13
26
26
54
54
40
40
60
60

0
0
0
6
9
9
0
0
11
11
11
11
30
30
17
17
34
34

0
0
0
0
0
0
0
0
0
0
0
0
13
13
0
0
14
14

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
11

3
5
7
18
26
26
17
17
34
34
51
51
92
92
75
75
100
100

0
4
6
8
22
22
15
15
15
15
30
30
60
60
44
44
66
66

0
0
0
7
10
10
0
0
13
13
13
13
36
36
19
19
38
38

0
0
0
0
0
0
0
0
0
0
0
0
14
14
0
0
15
15

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

98
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 99

Maximum Physical Terminal Block Content

4. To complete Catalog Number, Refer to Catalog Page
indicated next to the enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

Cat. Page

UK 2,5 N

UK 3 N

UK 5 N

UK 6 N

UK 10 N

UK 16 N

UK 35

UKH 50

MBK 2,5/E-EX

MBK 6/E

UK 3-RETURN

MZB 1,5

MZB 1,5-NS 35

MZDB 1,5

MZDB 1,5-NS 35

ZFK 1,5

ZKF 2,5

ZFK 4

ZFK 6

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

8
12
17
44
64
64
42
42
84
84
126
126
224
224
183
183
244
244

8
12
17
44
64
64
42
42
84
84
126
126
224
224
183
183
244
244

6
10
14
38
54
54
35
35
70
70
105
105
188
188
153
153
204
204

5
8
11
28
40
40
26
26
52
52
78
78
144
144
117
117
156
156

0
6
9
11
32
32
21
21
21
21
42
42
84
84
62
62
93
93

0
0
0
9
13
13
0
0
18
18
18
18
48
48
26
26
52
52

0
0
0
0
0
0
0
0
0
0
0
0
19
19
0
0
21
21

0
0
0
0
0
0
0
0
0
0
0
0
14
14
0
0
16
16

6
10
28
38
81
81
35
35
70
70
140
140
235
235
204
204
255
255

5
8
11
28
40
40
26
26
52
52
78
78
144
144
117
117
195
195

8
12
17
22
64
64
42
42
42
42
126
126
224
224
183
183
244
244

8
12
17
44
96
96
42
42
84
84
126
126
224
224
183
183
305
305

8
12
17
44
64
64
42
42
84
84
126
126
224
224
183
183
244
244

4
6
8
22
48
48
21
21
42
42
63
63
112
112
93
93
155
155

4
6
8
22
32
32
21
21
42
42
63
63
112
112
93
93
124
124

0
16
22
28
80
80
52
52
52
52
104
104
210
210
152
152
228
228

0
12
17
22
64
64
42
42
42
42
84
84
168
168
122
122
183
183

0
10
14
19
54
54
35
35
35
35
70
70
141
141
102
102
153
153

0
8
11
14
40
40
26
26
26
26
52
52
108
108
78
78
117
117

3B–45

Enclosure Size

Manufacturer - Phoenix

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

99
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 100

Maximum Physical Terminal Block Content
4. To complete Catalog Number, Refer to Catalog Page
indicated next to the enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to the Heat Dissipation Table found on the
catalog page for the enclosure size you selected.

Manufacturer - Wago
Cat. Page

280-991

281-691

281-991

282-691

284-691

283-691

285-691

280-698

281-693

264-120

264-220

264-125

264-225

Enclosure Size

Cat. Page

WK 2.5/U

WK 4/U

WK 6/U

WKI 35/U

WKN 10/U

WKN 16/U

WKN 35/U

3B–46

Enclosure Size

Manufacturer - Wieland

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

0
13
18
22
64
64
42
42
42
42
84
84
168
168
122
122
244
244

0
11
15
19
54
54
36
36
36
36
72
72
144
144
104
104
208
208

0
11
15
19
54
54
36
36
36
36
72
72
144
144
104
104
156
156

0
8
11
15
42
42
27
27
27
27
54
54
111
111
80
80
120
120

0
6
9
12
34
34
22
22
22
22
44
44
87
87
64
64
96
96

0
0
0
10
14
14
0
0
18
18
18
18
48
48
27
27
54
54

0
0
0
0
0
0
0
0
0
0
12
12
17
17
18
18
18
18

8
13
18
22
64
64
42
42
42
42
126
126
168
168
183
183
244
244

0
11
15
19
54
54
36
36
36
36
72
72
144
144
104
104
156
156

7
11
15
40
84
84
37
37
74
74
111
111
196
196
162
162
270
270

5
8
11
28
60
60
26
26
52
52
78
78
140
140
114
114
190
190

7
11
15
40
56
56
37
37
74
74
111
111
196
196
162
162
216
216

4
6
9
24
34
34
22
22
44
44
66
66
116
116
96
96
128
128

-050503
-060604
-070704
-080804
-101006
-101008
-120604
-120605
-120805
-120806
-121206
-121208
-151506
-151508
-161206
-161208
-161606
-161608

3B–47
3B–48
3B–49
3B–50
3B–51
3B–52
3B–53
3B–54
3B–55
3B–56
3B–57
3B–58
3B–59
3B–60
3B–61
3B–62
3B–63
3B–64

7
12
17
22
66
66
43
43
43
43
129
129
232
232
189
189
252
252

6
10
14
19
54
54
36
36
36
36
108
108
192
192
159
159
212
212

4
8
11
14
40
40
27
27
27
27
81
81
108
108
117
117
156
156

0
0
0
0
0
0
0
0
0
0
0
0
29
29
0
0
31
31

0
0
8
11
16
16
0
0
21
21
42
42
87
87
62
62
93
93

0
0
0
0
13
13
0
0
0
0
18
18
48
48
26
26
52
52

0
0
0
0
0
0
0
0
0
0
0
0
18
18
0
0
19
19

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

100
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 101

3B–47

TSC Series - Screw Cover Terminal Enclosure 5''x 5''x 3''

Enclosure Material

Catalog Number

SS316L

TSC4X6-050503

SS304

TSC4X-050503

Steel, Powder Coated

TSC4-050503

Notes:
1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-050503U).
2. See the end of this section for applications
using multiple terminal block types.
3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
4. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
41
10
19
Maximum fill permitted based solely on
minimum wire bending space and
16
6
13
51
electrical clearances
20
2
7
14
25
3
8
16
35
2
6
15
Additional testing required,
Consult Factory
50
5
13

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to terminal
block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives you
the maximum number of terminal blocks permitted for proper heat
dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase the
wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired terminal
count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
101

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 102

TSC Series - Screw Cover Terminal Enclosure 6''x 6''x 4''

3B–48
Enclosure Material

Catalog Number

SS316L

TSC4X6-060604

SS304

TSC4X-060604

Steel, Powder Coated

TSC4-060604

Notes:
1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-060604U).
2. See the end of this section for applications
using multiple terminal block types.
3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
4. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
48
10
23
Maximum fill permitted based solely on
minimum wire bending space and
16
8
15
60
electrical clearances
20
3
9
17
25
9
9
19
35
2
7
18
Additional testing required,
Consult Factory
50
1
6
15

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
102
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 103

3B–49

TSC Series - Screw Cover Terminal Enclosure 7''x 7''x 4''

Enclosure Material

Catalog Number

SS316L

TSC4X6-070704

SS304

TSC4X-070704

Steel, Powder Coated

TSC4-070704

Notes:

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
51
10
25
Maximum fill permitted based solely on
minimum wire bending space and
16
8
16
64
electrical clearances
20
3
9
18
25
4
10
20
35
3
8
20
Additional testing required,
Consult Factory
50
1
6
16

1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-070704U).

Qualifying Enclosure for Increased Safety Certification

2. See the end of this section for applications
using multiple terminal block types.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.

2. Find the Current (amperage) you intend to apply to the conductor.

4. For Conduit/Cable entry spacings refer to
the end of this section.

3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted for
proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found. If
neither is possible, continue to the next size enclosure until the
desired terminal count is found.

The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
103
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 104

TSC Series - Screw Cover Terminal Enclosure 8''x 8''x 4''

3B–50
Enclosure Material

Catalog Number

SS316L

TSC4X6-080804

SS304

TSC4X-080804

Steel, Powder Coated

TSC4-080804

Notes:

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
55
10
27
Maximum fill permitted based solely on
minimum wire bending space and
16
9
17
69
electrical clearances
20
3
10
20
25
5
11
22
35
3
8
21
Additional testing required,
Consult Factory
50
1
7
17

1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-080804U).

Qualifying Enclosure for Increased Safety Certification

2. See the end of this section for applications
using multiple terminal block types.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.

2. Find the Current (amperage) you intend to apply to the conductor.

4. For Conduit/Cable entry spacings refer to
the end of this section.

3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired
terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.

104
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 105

3B–51

TSC Series - Screw Cover Terminal Enclosure 10''x 10''x 6''

Enclosure Material

Catalog Number

SS316L

TSC4X6-101006

SS304

TSC4X-101006

Steel, Powder Coated

TSC4-101006

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-101006-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-101006U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
77
10
37
Maximum fill permitted based solely on
minimum wire bending space and
16
13
25
97
electrical clearances
20
5
14
28
25
7
16
30
35
4
12
30
Additional testing required,
Consult Factory
50
1
9
24

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the
conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is
found. If neither is possible, continue to the next size
enclosure until the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
105

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 106

TSC Series - Screw Cover Terminal Enclosure 10''x 10''x 8''

3B–52
Enclosure Material

Catalog Number

SS316L

TSC4X6-101008

SS304

TSC4X-101008

Steel, Powder Coated

TSC4-101008

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-101008-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-101008U).
3. See the end of this section for
applications using multiple terminal block
types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
92
10
45
Maximum fill permitted based solely on
minimum wire bending space and
16
15
30
116
electrical clearances
20
6
17
33
25
8
19
36
35
5
14
35
Additional testing required,
Consult Factory
50
2
11
29

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired
terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.

106
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 107

3B–53

TSC Series - Screw Cover Terminal Enclosure 12''x 6''x 4''

Enclosure Material

Catalog Number

SS316L

TSC4X6-120604

SS304

TSC4X-120604

Steel, Powder Coated

TSC4-120604

Notes:

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
52
10
25
Maximum fill permitted based solely on
minimum wire bending space and
16
8
17
66
electrical clearances
20
3
9
19
25
4
10
20
35
3
8
20
Additional testing required,
Consult Factory
50
1
6
16

1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-120604U).

Qualifying Enclosure for Increased Safety Certification

2. See the end of this section for applications
using multiple terminal block types.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.

2. Find the Current (amperage) you intend to apply to the conductor.

4. For Conduit/Cable entry spacings refer to
the end of this section.

3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
107

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 108

TSC Series - Screw Cover Terminal Enclosure 12''x 6''x 5''

3B–54
Enclosure Material

Catalog Number

SS316L

TSC4X6-120605

SS304

TSC4X-120605

Steel, Powder Coated

TSC4-120605

Notes:

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
59
10
29
Maximum fill permitted based solely on
minimum wire bending space and
16
10
19
74
electrical clearances
20
4
11
21
25
5
12
23
35
3
9
23
Additional testing required,
Consult Factory
50
1
7
19

1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-120605U).

Qualifying Enclosure for Increased Safety Certification

2. See the end of this section for applications
using multiple terminal block types.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.

2. Find the Current (amperage) you intend to apply to the conductor.

4. For Conduit/Cable entry spacings refer to
the end of this section.

3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired
terminal count is found.

The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
108
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 109

3B–55

TSC Series - Screw Cover Terminal Enclosure 12''x 8''x 5''

Enclosure Material

Catalog Number

SS316L

TSC4X6-120805

SS304

TSC4X-120805

Steel, Powder Coated

TSC4-120805

Notes:
1. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-120805U).

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
67
10
32
Maximum fill permitted based solely on
minimum wire bending space and
16
11
21
84
electrical clearances
20
4
12
24
25
6
14
26
35
4
10
26
Additional testing required,
Consult Factory
50
1
8
21

Qualifying Enclosure for Increased Safety Certification

2. See the end of this section for applications
using multiple terminal block types.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.

2. Find the Current (amperage) you intend to apply to the conductor.

4. For Conduit/Cable entry spacings refer to
the end of this section.

3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired
terminal count is found.

The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
109
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 110

TSC Series - Screw Cover Terminal Enclosure 12''x 8''x 6''

3B–56
Enclosure Material

Catalog Number

SS316L

TSC4X6-120806

SS304

TSC4X-120806

Steel, Powder Coated

TSC4-120806

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-120806-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-120806U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
74
10
36
Maximum fill permitted based solely on
minimum wire bending space and
16
12
24
93
electrical clearances
20
5
14
27
25
6
15
29
35
4
11
28
Additional testing required,
Consult Factory
50
1
9
23

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the
conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found.
If neither is possible, continue to the next size enclosure until
the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.

110
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 111

3B–57

TSC Series - Screw Cover Terminal Enclosure 12''x 12''x 6''

Enclosure Material

Catalog Number

SS316L

TSC4X6-121206

SS304

TSC4X-121206

Steel, Powder Coated

TSC4-121206

Notes:

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
85
10
41
Maximum fill permitted based solely on
minimum wire bending space and
16
14
27
107
electrical clearances
20
5
16
31
25
7
17
33
35
5
13
33
Additional testing required,
Consult Factory
50
1
10
27

1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-121206-ABCD).

Qualifying Enclosure for Increased Safety Certification

2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-121206U).

2. Find the Current (amperage) you intend to apply to the
conductor.

3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted for
proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found.
If neither is possible, continue to the next size enclosure until
the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
111

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 112

TSC Series - Screw Cover Terminal Enclosure 12''x 12''x 8''

3B–58
Enclosure Material

Catalog Number

SS316L

TSC4X6-121208

SS304

TSC4X-121208

Steel, Powder Coated

TSC4-121208

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-121208-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-121208U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
100
10
48
Maximum fill permitted based solely on
minimum wire bending space and
16
16
32
125
electrical clearances
20
7
19
36
25
9
20
39
35
6
15
38
Additional testing required,
Consult Factory
50
2
12
32

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the
conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is
found. If neither is possible, continue to the next size
enclosure until the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.

112
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 113

3B–59

TSC Series - Screw Cover Terminal Enclosure 15''x 15''x 6''

Enclosure Material

Catalog Number

SS316L

TSC4X6-151506

SS304

TSC4X-151506

Steel, Powder Coated

TSC4-151506

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-151506-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-151506U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
96
10
46
Maximum fill permitted based solely on
minimum wire bending space and
16
16
31
121
electrical clearances
20
6
18
35
25
8
19
38
35
5
15
37
Additional testing required,
Consult Factory
50
2
12
30

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the
conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found.
If neither is possible, continue to the next size enclosure until
the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
113

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 114

TSC Series - Screw Cover Terminal Enclosure 15''x 15''x 8''

3B–60
Enclosure Material

Catalog Number

SS316L

TSC4X6-151508

SS304

TSC4X-151508

Steel, Powder Coated

TSC4-151508

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-151508-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-151508U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
111
10
54
Maximum fill permitted based solely on
minimum wire bending space and
16
18
36
139
electrical clearances
20
7
21
40
25
10
23
44
35
6
17
43
Additional testing required,
Consult Factory
50
2
14
35

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the
conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found.
If neither is possible, continue to the next size enclosure until
the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.

114
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 115

3B–61

TSC Series - Screw Cover Terminal Enclosure 16''x 12''x 6''

Enclosure Material

Catalog Number

SS316L

TSC4X6-161206

SS304

TSC4X-161206

Steel, Powder Coated

TSC4-161206

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-161206-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-161206U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
90
10
44
Maximum fill permitted based solely on
minimum wire bending space and
16
15
29
113
electrical clearances
20
6
17
33
25
8
18
36
35
5
14
35
Additional testing required,
Consult Factory
50
2
11
29

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the
conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found.
If neither is possible, continue to the next size enclosure until
the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
115

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 116

TSC Series - Screw Cover Terminal Enclosure 16''x 12''x 8''

3B–62
Enclosure Material

Catalog Number

SS316L

TSC4X6-161208

SS304

TSC4X-161208

Steel, Powder Coated

TSC4-161208

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-161208-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-161208U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
105
10
51
Maximum fill permitted based solely on
minimum wire bending space and
16
17
34
132
electrical clearances
20
7
20
38
25
9
21
41
35
6
16
40
Additional testing required,
Consult Factory
50
2
13
33

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted for
proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found. If
neither is possible, continue to the next size enclosure until the
desired terminal count is found.

The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
116
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 117

3B–63

TSC Series - Screw Cover Terminal Enclosure 16''x 16''x 6''

Enclosure Material

Catalog Number

SS316L

TSC4X6-161606

SS304

TSC4X-161606

Steel, Powder Coated

TSC4-161606

Notes:
1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-161606-ABCD).
2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-161606U).
3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
100
10
48
Maximum fill permitted based solely on
minimum wire bending space and
16
16
32
125
electrical clearances
20
7
19
36
25
9
20
39
35
6
15
38
Additional testing required,
Consult Factory
50
2
12
32

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired
terminal count is found.

The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.
117
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 118

TSC Series - Screw Cover Terminal Enclosure 16''x 16''x 8''

3B–64
Enclosure Material

Catalog Number

SS316L

TSC4X6-161608

SS304

TSC4X-161608

Steel, Powder Coated

TSC4-161608

Notes:

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm5)
(amps)
1.5
2.5
4
6
10
16
8
115
10
56
Maximum fill permitted based solely on
minimum wire bending space and
16
19
37
144
electrical clearances
20
8
21
42
25
10
23
45
35
7
18
44
Additional testing required,
Consult Factory
50
2
14
36

1. For Gland Plates add suffixes -A (top),
-B (bottom), -C (left), -D (right) immediately
following the catalog number
(i.e. TSC4X6-161608-ABCD).

Qualifying Enclosure for Increased Safety Certification

2. For Empty Enclosures add U immediately
following the catalog number
(i.e. TSC4X6-161608U).

2. Find the Current (amperage) you intend to apply to the
conductor.

3. See the end of this section for applications
using multiple terminal block types.
4. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
5. For Conduit/Cable entry spacings refer to
the end of this section.

1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.

3. The intersection of the Wire Size (column) and Current (row)
gives you the maximum number of terminal blocks permitted
for proper heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or
increase the wire size until the desired terminal count is found.
If neither is possible, continue to the next size enclosure until
the desired terminal count is found.
The Adalet Engineering Department is available to assist you in the
selection of Increased Safety Enclosures.

118
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 119

Qualifying Enclosures for Increased Safety Certification
with Multiple Terminal Block Types
Current
(amps)
8
10
16
20
25
35
50

1.5
90
44
15
6

Maximum Terminal Block Wire Size (mm5)
2.5
4
6
10

29
17
8

Additional Testing Required,
Consult Factory

113
33
18
5

16

Maximum fill permitted based solely
on minimum wire bending space and
electrical clearances

36
14
2

35
11

29

Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below.
Example:
Current

Number

% of Maximum Terminal Population

2.5

16

7 (of 29)

=

24%

4

20

16 (of 33)

=

48%

10

35

9 (of 35)

=

26%

Total

=

98%

<

3B–65

Conductor Size

100%

Notes:
1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the
conductor size and the continuous current for the designated enclosures.
2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and
manufacturer's instructions.
3. Grounding terminals, bridges and grounding conductors are not counted.
4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges.
5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals
and conductors should be considered.
6. Combinations not covered by the above tables may be permitted if they are determined acceptable by test.

119
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 120

Conduit/Cable & Wire Bending Guidelines
Table A - Minimum Spacing Between Centers of Conduit or Cable Entries

3B–66

SIZE

NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

NPT

METRIC

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

1/16 ~ 3/8

--

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

1-1/8
[29mm]

1/2

M16

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

3/4

M20

4-1/2
[115mm]

3-3/4
[96mm]

3-1/2
3-1/8
[89mm] [80mm]

2-3/4
[70mm]

2-1/2
[64mm]

2-1/8
[54mm]

2
[51mm]

1-3/4
[45mm]

1-1/2
[38mm]

1

M25

4-5/8
[118mm]

3-7/8
[99mm]

3-5/8
3-1/4
[92mm] [83mm]

2-7/8
[74mm]

2-3/4
[70mm]

2-1/4
[58mm]

2-1/8
[54mm]

1-7/8
[48mm]

1-1/4

M32

4-7/8
[124mm]

4-1/8
[105mm]

3-7/8
[99mm

3-1/2
[89mm]

3-1/8
[80mm]

2-7/8
[74mm]

2-1/2
[64mm]

2-3/8
[61mm]

1-1/2

M40

5
[127mm]

4-1/4
4
3-5/8
[108mm] [102mm] [92mm]

3-1/4
[83mm]

3
[77mm]

2-5/8
[68mm]

2

M50

5-3/8
[137mm]

4-3/4
4-1/2
4
3-5/8
[121mm] [115mm] [102mm] [92mm]

3-3/8
[86mm]

2-1/2

M63

5-1/2
[140mm]

4-7/8
4-5/8
4-1/4
3-7/8
[124mm] [118mm] [108mm] [99mm]

3

M75

5-7/8
[150mm]

5-1/4
5
4-5/8
[134mm] [127mm] [118mm]

3-1/2

--

6-1/4
[159mm]

5-3/4
5-1/2
[147mm] [140mm]

4

--

6-7/8
[175mm]

6
[153mm]

5

--

7-3/8
[188mm]

This information is compiled from data which we believe is
reliable and is given in good faith. Since the methods of
application and condition under which our products are used are
beyond our control, we are not able to guarantee the application
and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

2-13/16
[72mm]

2-1/4
[58mm]

2
[51mm]

1-3/16
[31mm]

1
[26mm]

7/8
[23mm]

11/16
[18mm]

9/16
[14mm]

1/2
[13mm]

1/2
[13mm]

METRIC

1-3/4
1-7/16
[45mm] [37mm]

Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls
AWG

16

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

250

350

400

500

mm sq.

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

1-1/2
1-1/2 1-1/2 1-1/2
2
3
3-1/2
5-1/2
6
6-1/2
7
8-1/2
10
12
13
14
[38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm]
Notes:
1. The distances in Table A are recommended minimum
distances between centers of conduit and cable gland
entries. Consult manufacturer of conduit fitting or cable
glands for their recommended minimum spacing.

entries to the edge of an opening or inside wall of box.
Consult manufacturer of conduit fitting or cable glands for
their recommended minimum spacing.
3. The distances in Table C are the minimum wire bending
space requirements between terminals, partitions, or inside
walls.

2. The distances in Table B are recommended minimum
distances between center of conduit and cable gland
120
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 121

TFG Series

Close-up Plugs:
Any unused entries must be plugged
with a Certified Close-Up Plug. Adalet
can provide close-up plugs in various
styles and materials. Please indicate on
the sketch or provide detailed
information of holes to be plugged.

Enclosure Labeling:
Adalet can provide additional enclosure
labeling with custom silk screening or
various colors of Lamacoid™
nameplates. Please provide detailed
information of the logo or text required.

18 Enclosure Sizes
3B–67

Breather Drains:

Available in 18 sizes, from 6”x4”x4” (model 060406) to
(model 201610).

Breather Drains can be provided per customer request.
They are available in Brass or Stainless Steel 316L. Please
indicate on a sketch or provide detailed information for
locations.

Construction
•

Compression Molded, Fiberglass Reinforced Polyester

•

Memory Retaining, Poured In Place Silicone Gasket

•

Molded Mounting Feet with 5/16” Clearance Holes

Grounding Busbars:

•

Captive Cover Screws

•

Universal Rail Mounting System

Some applications might require grounding points to be
terminated in the enclosure. With the use of a Ground
Busbar System this can be accomplished, consult factory
for options.

Options
Hinged Cover:

Mounting Pans:

A stainless steel piano type hinge is available by adding an H
to the end of the catalog string. (i.e. TFG-201407H)

As an alternative to the universal rail mounting system,
mounting pans are available in steel/powder coated,
stainless steel, and aluminum. Please indicate when
requesting quote.

Earthing Stud Assembly:
An Internal/External Earthing Stud can be provided upon
request. Please specify on the request for quote.

Terminal Strip Assemblies:
Various options (i.e. marking tags, protective covers,
jumpers, partitions,..) are available. Please provide detailed
information requesting quote.

Conduit/Cable Entries:
Entries can be provided per a customer sketch or with
detailed information on the entry locations. Please refer to
Entry Spacing Tables at the end of the Increased Safety
Section in the CENELEC Product Catalog. Note: This
information is important and could affect the size of the
enclosure you selected.

121
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 122

TFG Series - Screw Cover Terminal Enclosure
General Information
Adalet's TFG Series of Increased Safety Terminal Enclosures are
compression molded from a fiberglass reinforced polyester resin.
Available in (18) sizes with integral mounting feet and a minimum
wall section thickness of 3mm, these enclosures are ideal for
indoor and outdoor areas where dampness and highly corrosive
atmospheres are present. Suitable for Petrochemical, Water
Treatment, Food Processing, Coating, Salts and Chemical
applications, they are also ideal for installation where weight is a
prime factor in enclosure selection.

Enclosure Certifications with Terminals

3B–68

0539
II 2GD
EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Empty Enclosure Certifications
0539
II 2GD
EEx e II
Ex e II
Class I, Zone 1, AEx e II
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
Working Voltage
Terminal Blocks
Various manufacturers
Material
Enclosure
Mounting Pan
Gasket
Cover
Lid Fixing
All Types
Enclosure Mounting
All Types
Grounding
All Types
Impact Resistant
All Types
Ambient Temperature Range
All Types

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50

D

ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50
1100 Volts Maximum
EEx e type with wire sizes 1.5mm up to 16mm
Fiberglass Reinforced Polyester - 3mm Wall Section Thickness
.08 Aluminum, Steel - Painted, or Stainless Steel
Silicone
Captive Cover Screws - Stainless Steel
External mounting feet with .31'' clearance holes
Grounding Terminal Block (sized for the largest conductor used)
7 Nm to EN50014/EN50019
-40°C to +70°C to EN50014

D

122
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 123

TFG Series - Quick Selector
4. To complete catalog number, refer to catalog page
indicated next to enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block size
for your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications
1. Using the table below, refer to the Heat Dissipation Table
found on the catalog page for the enclosure size you
selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size for
your application.

Maximum Physical Terminal Block Content
Enclosure

Catalog

Sizes

Page

1.5mm

2.5mm

4mm

-060404

3B–78

0

9

7

0

0

0

0

0

0

-060406

3B–79

0

9

7

0

0

0

0

0

0

-060604

3B–80

10

9

7

6

5

0

0

0

0

-060606

3B–81

10

9

7

6

5

0

0

0

0

-080604

3B–82

20

16

15

12

10

0

0

0

0

-080606

3B–83

20

16

15

12

10

0

0

0

0

-100804

3B–84

60

25

23

36

15

12

0

0

0

-100806

3B–85

60

25

23

36

15

12

0

0

0

-121005

3B–86

80

66

60

50

40

17

0

0

0

-121006

3B–87

80

66

60

50

40

17

0

0

0

-141206

3B–88

150

123

114

93

50

21

0

0

0

-141207

3B–89

150

123

114

93

50

21

0

0

0

-161406

3B–90

183

150

138

148

90

50

19

0

0

-161407

3B–91

183

150

138

148

90

50

19

0

0

-181608

3B–92

284

232

212

172

105

58

22

17

16

-181610

3B–93

284

232

212

172

105

58

22

17

16

-201608

3B–94

324

264

244

200

120

68

25

20

18

-201610

3B–95

324

264

244

200

120

68

25

20

18

10mm 16mm

35mm

50mm 70mm

3B–69

6mm

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.
2. Quantities shown above are for Adalet supplied standard terminal blocks.

123
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 124

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete catalog number, refer to the catalog page
indicated next to enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
(H X W) for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Cat. Page

MA2,5/5…

MA2,5/5.1…

M4/6…

M6/8…

M10/10…

M16/12…

M35/16…

M4/6.H…

M1,5/6.HH

MTC6

MA2,5/5.SNB

M4/6.SN…

M4/6.SNB

3B–70

Enclosure
Size

Manufacturer - Entrelec

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
9
9
19
19
58
58
78
78
147
147
177
177
276
276
316
316

0
0
9
9
19
19
58
58
78
78
147
147
177
177
276
276
316
316

0
0
8
8
16
16
48
48
66
66
123
123
150
150
232
232
264
264

0
0
6
6
12
12
36
36
50
50
93
93
111
111
176
176
200
200

0
0
4
4
9
9
15
15
40
40
50
50
90
90
105
105
120
120

0
0
0
0
0
0
12
12
16
16
20
20
50
50
58
58
66
66

0
0
0
0
0
0
0
0
0
0
0
0
18
18
22
22
25
25

0
0
8
8
16
16
24
24
66
66
82
82
150
150
232
232
264
264

0
0
8
8
16
16
24
24
66
66
82
82
150
150
174
174
198
198

0
0
8
8
16
16
48
48
66
66
123
123
150
150
232
232
264
264

0
0
9
9
19
19
58
58
78
78
147
147
177
177
276
276
316
316

0
0
8
8
16
16
48
48
66
66
123
123
150
150
232
232
264
264

0
0
8
8
16
16
48
48
66
66
123
123
150
150
232
232
264
264

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

124
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 125

Maximum Physical Terminal Block Content

4. To complete catalog number, refer to the catalog page
indicated next to enclosure size you selected.

Enclosure Selection
1. Using the table below, select the terminal block type
for your application.

5. For Enclosure Selection using specific Terminal Block
Manufacturers refer to following pages.

2. Follow the column down until you find the quantity
required for your application.

For Increased Safety Applications
1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
(H X W) for your application.

2. Refer to catalog page for Heat Dissipation Tables.

DR4/6…

M35/26.FF

M70/31.FF

M35/26.AF

M70.31.AF

D4/6…ADO

D4/6.ADO.T…

D4/6.ADO…

D6/8…ADO

D6/8.ADO…

0
0
6
6
12
12
36
36
50
50
93
93
111
111
176
176
200
200

0
0
6
6
12
12
18
18
50
50
62
62
111
111
132
132
150
150

0
0
9
9
17
17
50
50
102
102
168
168
204
204
295
295
335
335

0
0
0
0
0
0
0
0
7
7
9
9
11
11
13
13
15
15

0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
11
13
13

0
0
0
0
0
0
0
0
7
7
9
9
11
11
13
13
15
15

0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
11
13
13

0
0
8
8
16
16
24
24
66
66
123
123
150
150
232
232
264
264

0
0
8
8
16
16
24
24
66
66
123
123
150
150
232
232
264
264

0
0
8
8
16
16
24
24
66
66
123
123
150
150
232
232
264
264

0
0
6
6
12
12
18
18
50
50
93
93
111
111
176
176
200
200

0
0
6
6
12
12
18
18
50
50
93
93
111
111
176
176
200
200

3B–71

M4/8.SN

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

M6/8.SNB

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

Cat. Page

Enclosure
Size

Manufacturer - Entrelec

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

125
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 126

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Cat. Page

WDU2.5N

WDU2.5

WDU4

WDU6

WDU10

WDU16

WDU35

WWF35

ZDU2.5

ZDU4

ZDU6

AKZ2.5

AKZ4

3B–72

Enclosure Size

Manufacturer - Weidmuller

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
10
10
20
20
60
60
80
80
150
150
183
183
284
284
324
324

0
0
10
10
20
20
30
30
80
80
100
100
183
183
213
213
243
243

0
0
10
10
20
20
30
30
80
80
100
100
183
183
213
213
243
243

0
0
6
6
12
12
19
19
50
50
64
64
114
114
135
135
153
153

0
0
0
0
0
0
15
15
20
20
50
50
60
60
105
105
123
123

0
0
0
0
0
0
0
0
17
17
21
21
50
50
58
58
68
68

0
0
0
0
0
0
0
0
0
0
0
0
19
19
22
22
25
25

0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
12
14
14

0
0
10
10
20
20
30
30
80
80
100
100
180
180
210
210
240
240

0
0
8
8
16
16
25
25
66
66
82
82
150
150
174
174
198
198

0
0
6
6
12
12
18
18
50
50
62
62
111
111
129
129
150
150

9
9
9
9
19
19
60
60
120
120
200
200
300
300
350
350
400
400

7
7
7
7
16
16
48
48
96
96
164
164
245
245
285
285
330
330

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

126
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 127

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Cat. Page

AKE2.5

AKE4

SAK2.5

SAK4

SAK6N

SAK10

SAK16

SAK35N

SAK70

SAKG 28 I

SAKG 28 II

SAKG 28 III

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
9
9
19
19
60
60
120
120
200
200
240
240
350
350
400
400

0
0
7
7
14
14
44
44
87
87
111
111
176
176
255
255
295
295

0
0
8
8
16
16
25
25
66
66
123
123
150
150
232
232
264
264

0
0
7
7
15
15
23
23
60
60
114
114
138
138
212
212
244
244

0
0
6
6
12
12
36
36
50
50
93
93
148
148
172
172
200
200

0
0
5
5
10
10
15
15
40
40
50
50
90
90
105
105
120
120

0
0
0
0
0
0
12
12
17
17
21
21
50
50
58
58
68
68

0
0
0
0
0
0
0
0
0
0
0
0
19
19
22
22
25
25

0
0
0
0
0
0
0
0
0
0
0
0
0
0
16
16
18
18

0
0
0
0
0
0
0
0
0
0
0
0
10
10
11
11
13
13

0
0
0
0
0
0
0
0
0
0
0
0
10
10
11
11
13
13

0
0
0
0
0
0
0
0
0
0
0
0
10
10
11
11
13
13

3B–73

Enclosure Size

Manufacturer - Weidmuller

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

127
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 128

Maximum Physical Terminal Block Content Manufacturer - Woretz

Enclosure Selection

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Cat. Page

30128 gr

3424 gr

3425 gr

3426 gr

3427 gr

3428 gr

3429 gr

30841 gr Ex

30842 gr Ex

30843 gr Ex

30844 gr Ex

3468 gr Ex

30111 gr

3301 gr

3B–74

Enclosure Size

Manufacturer - Woretz

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
8
8
17
17
25
25
68
68
126
126
153
153
236
236
272
272

0
0
8
8
17
17
25
25
68
68
126
126
153
153
236
236
272
272

0
0
6
6
12
12
19
19
50
50
96
96
114
114
176
176
204
204

0
0
0
0
0
0
17
17
22
22
56
56
68
68
117
117
135
135

0
0
0
0
0
0
0
0
18
18
23
23
54
54
64
64
74
74

0
0
0
0
0
0
0
0
0
0
0
0
21
21
25
25
29
29

0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
15
17
17

0
0
4
4
8
8
12
12
32
32
60
60
72
72
112
112
128
128

0
0
3
3
7
7
10
10
28
28
34
34
63
63
72
72
84
84

0
0
0
0
0
0
9
9
12
12
15
15
36
36
42
42
48
48

0
0
0
0
0
0
0
0
0
0
0
0
14
14
17
17
19
19

0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
12
14
14

0
0
8
8
17
17
25
25
68
68
126
126
153
153
236
236
272
272

0
0
8
8
17
17
25
25
68
68
126
126
153
153
236
236
272
272

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

128
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 129

Maximum Physical Terminal Block Content Manufacturer - Woretz

Enclosure Selection

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Cat. Page

3302 gr

3303 gr

3304 gr

3305 gr

3306 gr

3712 gr Ex

3713 gr Ex

3713/16 gr Ex

3714 gr Ex

3715 gr Ex

30831 gr Ex

30832 gr Ex

30833 gr Ex

30834 gr Ex

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
6
6
12
12
19
19
50
50
96
96
114
114
176
176
204
204

0
0
0
0
0
0
17
17
22
22
56
56
68
68
117
117
135
135

0
0
0
0
0
0
0
0
18
18
23
23
54
54
64
64
74
74

0
0
0
0
0
0
0
0
0
0
0
0
21
21
25
25
29
29

0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
15
17
17

0
0
3
3
7
7
22
22
28
28
54
54
66
66
100
100
116
116

0
0
3
3
6
6
9
9
24
24
32
32
57
57
66
66
75
75

0
0
0
0
0
0
8
8
10
10
13
13
32
32
36
36
42
42

0
0
0
0
0
0
0
0
0
0
0
0
14
14
16
16
18
18

0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
12
14
14

0
0
4
4
8
8
24
24
32
32
60
60
72
72
112
112
128
128

0
0
3
3
7
7
10
10
28
28
34
34
63
63
72
72
84
84

0
0
0
0
0
0
9
9
12
12
15
15
36
36
42
42
48
48

0
0
0
0
0
0
0
0
0
0
0
0
14
14
17
17
19
19

3B–75

Enclosure Size

Manufacturer - Woretz

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

129
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 130

Maximum Physical Terminal Block Content Manufacturer - Phoenix

Enclosure Selection

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Cat. Page

UK 2,5 N

UK 3 N

UK 5 N

UK 6 N

UK 10 N

UK 16 N

UK 35

UKH 50

MBK 2,5/E-EX

MBK 6/E

UK 3-RETURN

MZB 1,5

MZB 1,5-NS 35

MZDB 1,5

MZDB 1,5-NS 35

ZFK 1,5

ZKF 2,5

ZFK 4

ZFK 6

3B–76

Enclosure Size

Manufacturer - Phoenix

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
9
9
19
19
58
58
78
78
144
144
174
174
272
272
312
312

0
0
9
9
19
19
58
58
78
78
144
144
174
174
272
272
312
312

0
0
8
8
16
16
48
48
64
64
123
123
147
147
228
228
260
260

0
0
6
6
12
12
36
36
48
48
93
93
111
111
172
172
196
196

0
0
5
5
10
10
14
14
38
38
48
48
87
87
102
102
117
117

0
0
0
0
0
0
12
12
16
16
20
20
50
50
58
58
66
66

0
0
0
0
0
0
0
0
0
0
0
0
20
20
23
23
26
26

0
0
0
0
0
0
0
0
0
0
0
0
0
0
17
17
20
20

8
8
8
8
16
16
48
48
96
96
164
164
245
245
285
285
325
325

0
0
6
6
12
12
36
36
48
48
93
93
148
148
215
215
245
245

0
0
9
9
19
19
29
29
78
78
144
144
174
174
272
272
312
312

0
0
9
9
19
19
58
58
117
117
144
144
232
232
340
340
390
390

0
0
9
9
19
19
58
58
78
78
144
144
174
174
272
272
312
312

0
0
4
4
9
9
28
28
57
57
72
72
116
116
170
170
195
195

0
0
4
4
9
9
28
28
38
38
72
72
87
87
136
136
156
156

0
0
12
12
24
24
36
36
96
96
120
120
216
216
252
252
291
291

0
0
9
9
19
19
29
29
78
78
96
96
174
174
204
204
234
234

0
0
8
8
16
16
24
24
64
64
82
82
147
147
171
171
195
195

0
0
6
6
12
12
18
18
48
48
62
62
111
111
129
129
147
147

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

130
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 131

Maximum Physical Terminal Block Content

Enclosure Selection

4. To complete catalog number, refer to catalog page
indicated next to the enclosure size you selected.

1. Using the table below, select the terminal block type
for your application.

For Increased Safety Applications

2. Follow the column down until you find the quantity
required for your application.

1. Using the table below, find the catalog page for the
enclosure size you selected.

3. Follow the row left until you reach the Enclosure
Size column. This is the minimum enclosure size
for your application.

2. Refer to catalog page for Heat Dissipation Tables.

Manufacturer - Wago
Cat. Page

280-991

281-691

281-991

282-691

284-691

283-691

285-691

280-698

281-693

264-120

264-220

264-125

264-225

Enclosure Size

Cat. Page

WK 2.5/U

WK 4/U

WK 6/U

WKI 35/U

WKN 10/U

WKN 16/U

WKN 35/U

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
10
10
19
19
29
29
78
78
96
96
174
174
268
268
308
308

0
0
8
8
17
17
25
25
66
66
82
82
147
147
232
232
264
264

0
0
8
8
17
17
25
25
66
66
82
82
147
147
174
174
198
198

0
0
6
6
13
13
19
19
50
50
64
64
114
114
132
132
153
153

0
0
5
5
10
10
15
15
40
40
50
50
60
60
105
105
120
120

0
0
0
0
0
0
12
12
17
17
21
21
50
50
58
58
68
68

0
0
0
0
0
0
0
0
0
0
14
14
17
17
20
20
23
23

0
0
10
10
19
19
29
29
78
78
144
144
174
174
268
268
308
308

0
0
8
8
17
17
25
25
66
66
82
82
147
147
174
174
198
198

0
0
8
8
17
17
50
50
102
102
126
126
204
204
295
295
340
340

0
0
6
6
12
12
36
36
72
72
90
90
144
144
210
210
240
240

0
0
8
8
17
17
50
50
68
68
126
126
204
204
236
236
272
272

0
0
5
5
10
10
30
30
40
40
75
75
120
120
140
140
160
160

-060404
-060406
-060604
-060606
-080604
-080606
-100804
-100806
-121005
-121006
-141206
-141207
-161406
-161407
-181608
-181610
-201608
-201610

3B–78
3B–79
3B–80
3B–81
3B–82
3B–83
3B–84
3B–85
3B–86
3B–87
3B–88
3B–89
3B–90
3B–91
3B–92
3B–93
3B–94
3B–95

0
0
9
9
19
19
29
29
80
80
150
150
180
180
280
280
320
320

0
0
8
8
16
16
25
25
66
66
123
123
150
150
232
232
268
268

0
0
6
6
12
12
18
18
50
50
93
93
111
111
176
176
200
200

0
0
0
0
0
0
0
0
0
0
0
0
30
30
35
35
40
40

0
0
0
0
0
0
14
14
20
20
50
50
60
60
105
105
120
120

0
0
0
0
0
0
0
0
16
16
20
20
50
50
58
58
66
66

0
0
0
0
0
0
0
0
0
0
0
0
18
18
22
22
25
25

3B–77

Enclosure Size

Manufacturer - Wieland

Notes:
1. All quantities shown are for terminal blocks installed in vertical rows.

131
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 132

TFG Series - Screw Cover Terminal Enclosure 6''x 4''x 4''

3B–78
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-060404

Hinged

TFG-060404H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
52
10
25
Maximum fill permitted based solely on
minimum wire bending space and
16
8
16
65
electrical clearances
20
3
9
19
25
4
10
20
35
3
8
20
Additional testing required,
Consult Factory
50
1
6
16

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither is
possible, continue to the next size enclosure until the desired
terminal count is found.

132
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 133

3B–79

TFG Series - Screw Cover Terminal Enclosure 6''x 4''x 6''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-060406

Hinged

TFG-060406H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
63
10
30
Maximum fill permitted based solely on
minimum wire bending space and
16
10
20
79
electrical clearances
20
4
12
23
25
5
13
25
35
3
9
24
Additional testing required,
Consult Factory
50
1
8
20

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

133
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 134

TFG Series - Screw Cover Terminal Enclosure 6''x 6''x 4''

3B–80
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-060604

Hinged

TFG-060604H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
57
10
28
Maximum fill permitted based solely on
minimum wire bending space and
16
9
18
72
electrical clearances
20
4
10
21
25
5
11
23
35
3
9
22
Additional testing required,
Consult Factory
50
1
7
18

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

134
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 135

3B–81

TFG Series - Screw Cover Terminal Enclosure 6''x 6''x 6''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-060606

Hinged

TFG-060606H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
69
10
33
Maximum fill permitted based solely on
minimum wire bending space and
16
11
22
86
electrical clearances
20
4
13
25
25
6
14
27
35
4
10
26
Additional testing required,
Consult Factory
50
1
8
22

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
135

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 136

TFG Series - Screw Cover Terminal Enclosure 8''x 6''x 4''

3B–82
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-080604

Hinged

TFG-080604H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
60
10
29
Maximum fill permitted based solely on
minimum wire bending space and
16
10
19
75
electrical clearances
20
4
11
22
25
5
12
24
35
3
9
23
Additional testing required,
Consult Factory
50
1
7
19

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

136
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 137

3B–83

TFG Series - Screw Cover Terminal Enclosure 8''x 6''x 6''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-080606

Hinged

TFG-080606H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
71
10
34
Maximum fill permitted based solely on
minimum wire bending space and
16
11
23
89
electrical clearances
20
4
13
26
25
6
14
28
35
4
11
27
Additional testing required,
Consult Factory
50
1
9
22

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
137

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 138

TFG Series - Screw Cover Terminal Enclosure 10''x 8''x 4''

3B–84
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-100804

Hinged

TFG-100804H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
64
10
31
Maximum fill permitted based solely on
minimum wire bending space and
16
10
20
80
electrical clearances
20
4
12
23
25
5
13
25
35
3
10
24
Additional testing required,
Consult Factory
50
1
8
20

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

138
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 139

3B–85

TFG Series - Screw Cover Terminal Enclosure 10''x 8''x 6''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-100806

Hinged

TFG-100806H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
82
10
39
Maximum fill permitted based solely on
minimum wire bending space and
16
13
26
102
electrical clearances
20
5
15
29
25
7
16
32
35
5
12
31
Additional testing required,
Consult Factory
50
1
10
26

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
139

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 140

TFG Series - Screw Cover Terminal Enclosure 12''x 10''x 5''

3B–86
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-121005

Hinged

TFG-121005H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
79
10
38
Maximum fill permitted based solely on
minimum wire bending space and
16
13
25
99
electrical clearances
20
5
15
28
25
7
16
31
35
4
12
30
Additional testing required,
Consult Factory
50
1
10
25

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

140
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 141

3B–87

TFG Series - Screw Cover Terminal Enclosure 12''x 10''x 6''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-121006

Hinged

TFG-121006H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
89
10
43
Maximum fill permitted based solely on
minimum wire bending space and
16
15
29
112
electrical clearances
20
6
16
32
25
8
18
35
35
5
14
34
Additional testing required,
Consult Factory
50
4
11
28

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
141

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 142

TFG Series - Screw Cover Terminal Enclosure 14''x 12''x 6''

3B–88
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-141206

Hinged

TFG-141206H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
94
10
46
Maximum fill permitted based solely on
minimum wire bending space and
16
15
30
118
electrical clearances
20
6
17
34
25
8
19
37
35
5
14
36
Additional testing required,
Consult Factory
50
2
12
30

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

142
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 143

3B–89

TFG Series - Screw Cover Terminal Enclosure 14''x 12''x 7''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-141207

Hinged

TFG-141207H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
105
10
51
Maximum fill permitted based solely on
minimum wire bending space and
16
17
34
131
electrical clearances
20
7
19
38
25
9
21
41
35
6
16
40
Additional testing required,
Consult Factory
50
2
13
38

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
143

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 144

TFG Series - Screw Cover Terminal Enclosure 16''x 14''x 6''

3B–90
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-161406

Hinged

TFG-161406H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
102
10
49
Maximum fill permitted based solely on
minimum wire bending space and
16
17
33
128
electrical clearances
20
7
19
37
25
9
21
40
35
6
15
39
Additional testing required,
Consult Factory
50
2
12
32

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

144
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 145

3B–91

TFG Series - Screw Cover Terminal Enclosure 16''x 14''x 7''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-161407

Hinged

TFG-161407H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
113
10
55
Maximum fill permitted based solely on
minimum wire bending space and
16
18
36
142
electrical clearances
20
7
21
41
25
10
23
45
35
6
17
43
Additional testing required,
Consult Factory
50
2
14
36

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
145

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 146

TFG Series - Screw Cover Terminal Enclosure 18''x 16''x 8''

3B–92
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-181608

Hinged

TFG-181608H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
128
10
62
Maximum fill permitted based solely on
minimum wire bending space and
16
21
41
161
electrical clearances
20
8
24
46
25
11
26
51
35
7
20
49
Additional testing required,
Consult Factory
50
3
16
41

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

146
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 147

3B–93

TFG Series - Screw Cover Terminal Enclosure 18''x 16''x 10''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-181610

Hinged

TFG-181610H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
142
10
69
Maximum fill permitted based solely on
minimum wire bending space and
16
23
46
178
electrical clearances
20
9
26
51
25
12
29
56
35
8
22
55
Additional testing required,
Consult Factory
50
3
18
45

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.
147

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 148

TFG Series - Screw Cover Terminal Enclosure 20''x 16''x 8''

3B–94
Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-201608

Hinged

TFG-201608H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm2)
(amps)
1.5
2.5
4
6
10
16
8
131
10
63
Maximum fill permitted based solely on
minimum wire bending space and
16
21
42
164
electrical clearances
20
9
24
47
25
11
27
52
35
8
20
50
Additional testing required,
Consult Factory
50
3
16
42

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

148
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 149

3B–95

TFG Series - Screw Cover Terminal Enclosure 20''x 16''x 10''

Enclosure Type

Catalog Number

Chained, Lift-Off

TFG-201610

Hinged

TFG-201610H

Notes:
1. See the end of this section for applications
using multiple terminal block types.
2. For other manufacturers of EEx 'e' type
terminal blocks, please consult factory.
3. For Conduit/Cable entry spacings refer to
the end of this section.
The Adalet Engineering Department is
available to assist you in the selection of
Increased Safety Enclosures.

Terminal Block Population for Increased Safety Heat Dissipation Requirements
Current
Maximum Terminal Block Wire Size (mm5)
(amps)
1.5
2.5
4
6
10
16
8
144
10
70
Maximum fill permitted based solely on
minimum wire bending space and
16
24
46
181
electrical clearances
20
10
27
52
25
13
29
57
35
8
22
55
Additional testing required,
Consult Factory
50
3
18
46

Qualifying Enclosure for Increased Safety Certification
1. Find the Wire Size (conductor) you intend to use to connect to
terminal block.
2. Find the Current (amperage) you intend to apply to the conductor.
3. The intersection of the Wire Size (column) and Current (row) gives
you the maximum number of terminal blocks permitted for proper
heat dissipation and Increased Safety Certification.
4. If the terminal count is too small, decrease the current or increase
the wire size until the desired terminal count is found. If neither
is possible, continue to the next size enclosure until the desired
terminal count is found.

149
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 150

Qualifying Enclosures for Increased Safety Certification
with Multiple Terminal Block Types
Current
(amps)
8
10
16
20
25
35
50

1.5
90
44
15
6

Maximum Terminal Block Wire Size (mm5)
2.5
4
6
10

29
17
8

113
33
18
5

Additional Testing Required,
Consult Factory

16

Maximum fill permitted based solely
on minimum wire bending space and
electrical clearances

36
14
2

35
11

29

Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below.
Example:
Current

Number

2.5

16

7 (of 29)

=

24%

4

20

16 (of 33)

=

48%

10

35

9 (of 35)

=

26%

Total

=

98%

3B–96

Conductor Size

% of Maximum Terminal Population

<

100%

Notes:
1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor
size and the continuous current for the designated enclosures.
2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and
manufacturer's instructions.
3. Grounding terminals, bridges and grounding conductors are not counted.
4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges.
5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals
and conductors should be considered.
6. Combinations not covered by the above tables may be permitted if they are determined acceptable by test.

150
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 B 12/9/01 10:47 AM Page 151

Conduit/Cable & Wire Bending Guidelines
Table A - Minimum Spacing Between Centers of Conduit or Cable Entries
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

NPT

METRIC

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

1/16 ~ 3/8

--

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

1-1/8
[29mm]

1/2

M16

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

3/4

M20

4-1/2
[115mm]

3-3/4
[96mm]

3-1/2
3-1/8
[89mm] [80mm]

2-3/4
[70mm]

2-1/2
[64mm]

2-1/8
[54mm]

2
[51mm]

1-3/4
[45mm]

1-1/2
[38mm]

1

M25

4-5/8
[118mm]

3-7/8
[99mm]

3-5/8
3-1/4
[92mm] [83mm]

2-7/8
[74mm]

2-3/4
[70mm]

2-1/4
[58mm]

2-1/8
[54mm]

1-7/8
[48mm]

1-1/4

M32

4-7/8
[124mm]

4-1/8
[105mm]

3-7/8
[99mm

3-1/2
[89mm]

3-1/8
[80mm]

2-7/8
[74mm]

2-1/2
[64mm]

2-3/8
[61mm]

1-1/2

M40

5
[127mm]

4-1/4
4
3-5/8
[108mm] [102mm] [92mm]

3-1/4
[83mm]

3
[77mm]

2-5/8
[68mm]

2

M50

5-3/8
[137mm]

4-3/4
4-1/2
4
3-5/8
[121mm] [115mm] [102mm] [92mm]

3-3/8
[86mm]

2-1/2

M63

5-1/2
[140mm]

4-7/8
4-5/8
4-1/4
3-7/8
[124mm] [118mm] [108mm] [99mm]

3

M75

5-7/8
[150mm]

5-1/4
5
4-5/8
[134mm] [127mm] [118mm]

3-1/2

--

6-1/4
[159mm]

5-3/4
5-1/2
[147mm] [140mm]

4

--

6-7/8
[175mm]

6
[153mm]

5

--

7-3/8
[188mm]

3B–97

SIZE

This information is compiled from data which we believe is
reliable and is given in good faith. Since the methods of
application and condition under which our products are used are
beyond our control, we are not able to guarantee the application
and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

2-13/16
[72mm]

2-1/4
[58mm]

2
[51mm]

1-3/16
[31mm]

1
[26mm]

7/8
[23mm]

11/16
[18mm]

9/16
[14mm]

1/2
[13mm]

1/2
[13mm]

METRIC

1-3/4
1-7/16
[45mm] [37mm]

Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls
AWG

16

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

250

350

400

500

mm sq.

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

1-1/2
1-1/2 1-1/2 1-1/2
2
3
3-1/2
5-1/2
6
6-1/2
7
8-1/2
10
12
13
14
[38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm]
Notes:
1. The distances in Table A are recommended minimum
distances between centers of conduit and cable gland
entries. Consult manufacturer of conduit fitting or cable
glands for their recommended minimum spacing.

2. The distances in Table B are recommended minimum
distances between center of conduit and cable gland entries
to the edge of an opening or inside wall of box. Consult
manufacturer of conduit fitting or cable glands for their
recommended minimum spacing.
3. The distances in Table C are the minimum wire bending space
requirements between terminals, partitions, or inside walls.
151

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 C 12/9/01 10:52 AM Page 152

HV Series - High Voltage Junction Boxes
Options
Gland Plates:
These removable plates offer great flexibility for the end user to
drill holes without having to remove the entire enclosure from
the installation site.
Add the following Suffixes:
-A: Gland Plate installed on top of box.
-B: Gland Plate installed on bottom of box.
-C: Gland Plate installed on left of box.
-D: Gland Plate installed on right of box.
For multiple gland plates omit dashes (i.e. HV4X-201407-ABCD)

Conduit/Cable Entries:

3C–1

Entries can be provided per a customer sketch or with detailed
information on the entry locations. Please refer to Entry Spacing
Tables at the end of this section. Note: This information is
important and could affect the size of the enclosure you
selected.

Close-up Plugs:

Construction

Any unused entries must be plugged with a Certified Close-Up
Plug. Adalet can provide close-up plugs in various styles and
materials. Please indicate on the sketch or provide detailed
information of holes to be plugged.

• Available in (3) Materials: SS304, SS316L, Powder Coated
(ASA61 Grey) Steel

Enclosure Labeling:

• Folded Lip around the Door Opening to provide complete
and maximum gasket seal

Adalet can provide additional enclosure labeling with custom silk
screening or various colors of Lamacoid™ nameplates. Please
provide detailed information of the logo or text required.

• Continuously Welded and Ground Smooth Seams
• Silicone Strip Gasket
• Welded on External Mounting Feet with 5/16” Clearance
Holes/Slot

Breather Drains:

• External Door Clamps
• Continuous Piano Type Hinge with Removable SS Hinge Pin
• Ground Studs on Box and Cover

Breather Drains can be provided per customer request. They are
available in Brass or Stainless Steel 316L. Please indicate on a
sketch or provided detailed information for locations.

• Internal/External Earthing Lugs
• Universal Rail Mounting System

Mounting Pans:

• Padlock Hasp & Staple for Padlocking

As an alternative to the universal rail mounting system,
mounting pans are available in steel/powder coated, stainless
steel, and aluminum. Please indicate when requesting quote.

152
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 C 12/9/01 10:52 AM Page 153

HV Series - High Voltage Junction Boxes
General Information
Adalet's Single Door Clamped High Voltage
Junction Boxes are available in Stainless Steel
316L & 304 and Carbon Steel. Silicone gaskets,
removable hinge pin, box & cover ground studs
including an internal/external earthing stud, and a
universal rail mounting system are included as
standard.

Working Voltage
Material

0539
II 2GD
EEx e II T6 (T5 Tamb +55°C)
Ex e II T6 (T5 Tamb +55°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C)
Class II, Division 2
IP66
Type 4, 4X (Stainless Steel only), 12, & 13
AC
HV4 Series
HV4X Series
HV4X6 Series
HV4 Series Gland Plates
HV4X Series Gland Plates
HV4X6 Series Gland Plates
Universal Rail System
Mounting Pan

Gasket
Lid Fixing

Hinge

Door Clamps

Enclosure Mounting
Gland Plate Hardware
Grounding
Impact Resistant
Ambient Temperature Range

Box & Cover
Earthing Lugs

HV4 Series
HV4X Series
HV4X6 Series
HV4 Series
HV4X Series
HV4X6 Series
All Types
All Types
All Types
All Types
All Types
All Types

3C–2

Enclosure Certifications
ATEX Directive 94/9/EC
EN50014/EN50019
CSA E79-7, IEC 60079-7
UL 2279-7
UL 1604
IEC 60529
UL50
8kV Maximum
#14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray
#14ga Stainless Steel 304, Brushed Finish
#14ga Stainless Steel 316, Brushed Finish
#10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray
#10ga Stainless Steel 304, Brushed Finish
#10ga Stainless Steel 316, Brushed Finish
300 Series Stainless Steel
#14ga Cold Rolled Steel, Polyester Powder Coated White
Silicone Sponge
Continuous piano type - Steel with removable SS304 pin
Continuous piano type - SS304 with removable pin
Continuous piano type - SS316 with removable pin
Plated Steel Clear
Stainless Steel 304
Stainless Steel 316
Four (4) external lugs with .44" clearance holes/slots
300 Series stainless steel
1/4-20 Stud with 300 series stainless steel hardware
#6-350MCM - Al/Cu
7 Nm to EN50014/EN50019
-40°C to +55°C to EN50014

D

153
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 C 12/9/01 10:52 AM Page 154

HV Series - High Voltage Junction Boxes 1 x 1 Connection Series
Shielded or Unshielded Cables

3C–3

SS316L
CATALOG NUMBERS

H

W

D

M

N

Maximum
Voltage

Maximum
Amps (T5/T6)

# of
Clamps

HV4X6-241206

610

305

152

664

241

1.5kV

315

5

HV4X6-242006

610

508

152

664

356

1.5kV

315

5

HV4X6-201206

508

305

152

562

241

2.5kV

250

4

HV4X6-161606

406

406

152

460

254

2.5kV

200

4

HV4X6-241606

610

406

152

664

254

2.5kV

315

5

HV4X6-301606

762

406

152

816

254

2.5kV

400

5

HV4X6-202006

508

508

152

562

356

2.5kV

250

4

HV4X6-201407

508

356

178

562

203

2.5kV

250

4

HV4X6-251807

635

457

178

689

305

2.5kV

315

5

HV4X6-302207

762

559

178

816

406

2.5kV

400

5

HV4X6-362507

914

635

178

968

483

2.5kV

400

8

HV4X6-201610

508

406

254

562

254

6.6kV

250

4

HV4X6-302010

762

508

254

816

356

8kV

400

5

HV4X6-242010

610

508

254

664

356

8kV

315

5

HV4X6-302410

762

762

254

816

458

8kV

400

5

HV4X6-242410

610

610

254

664

458

8kV

315

5

HV4X6-362410

914

610

254

968

458

8kV

400

5

HV4X6-362510

914

635

254

968

483

8kV

500

8

HV4X6-603610

1524

914

254

1578

762

8kV

500

9

HV4X6-603616

1524

914

406

1578

762

8kV

500

9

Notes:
1. For stainless steel 304 assemblies substitute HV4X6- prefix with HV4X- prefix.
2. For steel powder coated assemblies substitute HV4X6- prefix with HV4- prefix.
3. Please specify working voltage and amperage when requesting quote.
4. For conduit/cable entry spacing and minimum wire bending space requirements,
refer to the end of this section.
154
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

The Adalet Engineering
Department is available to assist
you in the selection of Increased
Safety Enclosures.

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 C 12/9/01 10:52 AM Page 155

HV Series - High Voltage Junction Boxes 2 x 2 Connection Series

SS316L
CATALOG NUMBERS

H

W

D

M

N

Maximum
Voltage

Maximum
Amps (T6)

Maximum
Amps (T5)

# of
Clamps

HV4X6-202008

508

508

203

562

356

1.1kV

500

500

4

HV4X6-242008

610

508

203

664

356

1.1kV

630

630

5

HV4X6-242408

610

610

203

664

458

1.1kV

630

630

5

HV4X6-202010

508

508

254

562

356

1.1kV

500

500

4

HV4X6-242010

610

508

254

664

356

1.1kV

630

630

5

HV4X6-302010

762

508

254

816

356

1.1kV

650

800

5

HV4X6-242410

610

610

254

664

458

1.1kV

630

630

5

HV4X6-302410

762

610

254

816

458

1.1kV

650

800

5

HV4X6-362410

914

610

254

968

458

1.1kV

650

800

5

HV4X6-362510

914

635

254

968

483

1.1kV

650

1000

8

HV4X6-603610

1524

914

254

1578

762

1.1kV

650

1000

9

3C–4

2 Parallel Unshielded Cables

Notes:
1. For stainless steel 304 assemblies substitute HV4X6- prefix with HV4X- prefix.
2. For steel powder coated assemblies substitute HV4X6- prefix with HV4- prefix.
3. Please specify working voltage and amperage when requesting quote.
4. For conduit/cable entry spacing and minimum wire bending space requirements,
refer to the end of this section.

The Adalet Engineering
Department is available to assist
you in the selection of Increased
Safety Enclosures.

155
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 C 12/9/01 10:52 AM Page 156

Conduit/Cable & Wire Bending Guidelines
Table A - Minimum Spacing Between Centers of Conduit or Cable Entries

3C–5

SIZE

NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

NPT

METRIC

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

1/16 ~ 3/8

--

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

1-1/8
[29mm]

1/2

M16

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

3/4

M20

4-1/2
[115mm]

3-3/4
[96mm]

3-1/2
3-1/8
[89mm] [80mm]

2-3/4
[70mm]

2-1/2
[64mm]

2-1/8
[54mm]

2
[51mm]

1-3/4
[45mm]

1-1/2
[38mm]

1

M25

4-5/8
[118mm]

3-7/8
[99mm]

3-5/8
3-1/4
[92mm] [83mm]

2-7/8
[74mm]

2-3/4
[70mm]

2-1/4
[58mm]

2-1/8
[54mm]

1-7/8
[48mm]

1-1/4

M32

4-7/8
[124mm]

4-1/8
[105mm]

3-7/8
[99mm

3-1/2
[89mm]

3-1/8
[80mm]

2-7/8
[74mm]

2-1/2
[64mm]

2-3/8
[61mm]

1-1/2

M40

5
[127mm]

4-1/4
4
3-5/8
[108mm] [102mm] [92mm]

3-1/4
[83mm]

3
[77mm]

2-5/8
[68mm]

2

M50

5-3/8
[137mm]

4-3/4
4-1/2
4
3-5/8
[121mm] [115mm] [102mm] [92mm]

3-3/8
[86mm]

2-1/2

M63

5-1/2
[140mm]

4-7/8
4-5/8
4-1/4
3-7/8
[124mm] [118mm] [108mm] [99mm]

3

M75

5-7/8
[150mm]

5-1/4
5
4-5/8
[134mm] [127mm] [118mm]

3-1/2

--

6-1/4
[159mm]

5-3/4
5-1/2
[147mm] [140mm]

4

--

6-7/8
[175mm]

6
[153mm]

5

--

7-3/8
[188mm]

This information is compiled from data which we believe is
reliable and is given in good faith. Since the methods of
application and condition under which our products are used are
beyond our control, we are not able to guarantee the application
and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

2-13/16
[72mm]

2-1/4
[58mm]

2
[51mm]

1-3/16
[31mm]

1
[26mm]

7/8
[23mm]

11/16
[18mm]

9/16
[14mm]

1/2
[13mm]

1/2
[13mm]

METRIC

1-3/4
1-7/16
[45mm] [37mm]

Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls
AWG

16

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

250

350

400

500

mm sq.

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

1-1/2
1-1/2 1-1/2 1-1/2
2
3
3-1/2
5-1/2
6
6-1/2
7
8-1/2
10
12
13
14
[38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm]
Notes:
1. The distances in Table A are recommended minimum
distances between centers of conduit and cable gland
entries. Consult manufacturer of conduit fitting or cable
glands for their recommended minimum spacing.

2. The distances in Table B are recommended minimum
distances between center of conduit and cable gland entries
to the edge of an opening or inside wall of box. Consult
manufacturer of conduit fitting or cable glands for their
recommended minimum spacing.
3. The distances in Table C are the minimum wire bending space
requirements between terminals, partitions, or inside walls.

156
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 157

CN Series
Auxiliary Devices:

85 Enclosure Sizes
Available in eighty-five (85) sizes, ranging from 16”x12”x6”
(model 161206) to 60”x36”x12” (model 603612).

Pushbuttons - Rated 250V, 16A (T6) - 11A (T5)

3D–1

• Single Button
• Dual

Construction

• Mushroom Head & Keyed Mushroom Head
• Available in (3) Materials: SS304, SS316L, Powder Coated
(ASA61 Grey) Steel
Selector Switches - Rated 250V, 16A (T6) - 11A (T5)

• Folded Lip around the Door Opening to provide complete
and maximum gasket seal

• Two or Three Position

• Continuously Welded and Ground Smooth Seams

• Keyed

• Silicone Strip Gasket

• Momentary or Maintained

• Welded on External Mounting Feet with 5/16” Clearance
Holes/Slot
• External Door Clamps

Pilot Lights - Rated 12-240VAC, 12-110VDC, W 1W

• Continuous Piano Type Hinge with Removable SS Hinge Pin

• Lens Colors: Blue, Green, Red, Yellow, White

• Ground Studs on Box and Cover
• Internal/External Earthing Stud

Potentiometers - Rated 250V

• Padlock Hasp & Staple for Padlocking

• 1W @ 1K, 4700, or 10K Ohms

Options

Measuring Instruments:

Gland Plates:

Ammeters, Voltmeters - Rated 420V or 750V

These removable plates offer great flexibility for the end user to
drill holes without having to remove the entire enclosure from
the installation site.

• Direct Measurement

Add the following Suffixes:

• Interchangeable Scales

• Indirect Measurement

-A: Gland Plate installed on top of box.
-B: Gland Plate installed on bottom of box.
-C: Gland Plate installed on left of box.
-D: Gland Plate installed on right of box.
For multiple gland plates omit dashes (i.e. CN4X-201407-ABCD)

157
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 158

CN Series
General Information
Adalet's Single Door Clamped Control Enclosures are available in
Stainless Steel 316L & 304 and Carbon Steel. Adalet can also
supply custom size enclosures, operators, and wiring of devices to
rail mounted terminal blocks to suit your Increased Safety
Application. Silicone gaskets, removable hinge pin, box & cover
ground studs including an internal/external earthing stud, along with
internal standoffs for mounting pans are included as standard.

3D–2
Enclosure Certifications
0539
II 2GD
EEx e II T6 Tamb +40°C (T5 Tamb +55°C)
IP66
Working Voltage
Terminal Blocks
Material

Gasket
Lid Fixing

Various Manufacturers
CN4 Series
CN4X Series
CN4X6 Series
CN4 Series Gland Plates
CN4X Series Gland Plates
CN4X6 Series Gland Plates
Mounting Pan
Hinge

Door Clamps

Enclosure Mounting
Gland Plate Hardware
Grounding
Impact Resistant
Ambient Temperature Range

Box & Cover
Earthing Stud

CN4 Series
CN4X Series
CN4X6 Series
CN4 Series
CN4X Series
CN4X6 Series
All Types
All Types
All Types
All Types
All Types
All Types

ATEX Directive 94/9/EC
EN50014/EN50019
IEC 60529
Up to 1100 Volts Maximum
EEx e type with wire sizes 1.5mm up to 240mm
#14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray
#14ga Stainless Steel 304, Brushed Finish
#14ga Stainless Steel 316, Brushed Finish
#10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray
#10ga Stainless Steel 304, Brushed Finish
#10ga Stainless Steel 316, Brushed Finish
#14ga Cold Rolled Steel, Polyester Powder Coated White
Silicone Sponge
Continuous piano type - Steel with removable SS304 pin
Continuous piano type - SS304 with removable pin
Continuous piano type - SS316 with removable pin
Plated Steel Clear
Stainless Steel 304
Stainless Steel 316
Four (4) external lugs with .44" clearance holes/slots
300 Series stainless steel
1/4-20 Stud with 300 series stainless steel hardware
1/4-20 Stud - All components brass
7 Nm to EN50014/EN50019
-20°C to +55°C to EN50014

D

158
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 159

CN Series – Catalog Numbers & Enclosure Sizes

ENCLOSURE
SIZE
-1224xx
-1612xx
-1616xx
-1620xx
-2012xx
-2016xx
-2020xx
-2024xx
-2412xx
-2416xx
-2420xx
-2424xx
-301606
-3020xx
-3024xx
-3624xx
-3630xx
-2430xx
-3030xx
-303608
-3636xx
-422408
-4230xx
-4236xx
-482408
-4830xx
-4836xx
-6036xx

H
305
406
406
406
508
508
508
508
610
610
610
610
762
762
762
914
914
610
762
762
914
1067
1067
1067
1219
1219
1219
1524

W
610
305
406
508
305
406
508
610
305
406
508
610
406
508
610
610
762
762
762
914
914
610
762
914
610
762
914
914

06
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
152
------------

08
203
203
203
203
203
203
203
203
203
203
203
203
-203
203
203
203
203
203
203
203
203
203
203
203
203
203
203

10
-254
---254
254
-254
-254
254
-254
254
254
254
-----254
254
-254
254
254

D
12
-----305
----305
305
--305
305
305
-305
-305
-305
305
--305
305

16
----------406
406
--406
-406
------406
--406
406

20
--------------508
-508
---------508
508

24
--------------588
------------588

M

N

S

T

359
460
460
460
562
562
562
562
664
664
664
664
816
816
816
968
968
664
816
816
968
1121
1121
1121
1273
1273
1273
1578

458
241
254
356
241
254
356
458
241
254
356
458
254
356
458
458
610
610
610
762
762
458
610
762
458
610
762
762

229
330
330
330
432
432
432
432
534
534
534
534
686
686
686
838
838
534
686
686
838
991
991
991
1143
1143
1143
1448

534
229
330
432
229
330
432
534
229
330
432
534
330
432
534
534
686
686
686
838
838
534
686
838
534
686
838
838

# OF
CLAMPS
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
7
7
7
7
7
6
8
8
6
8
8
9

3D–3

DIMENSIONS IN TABLE ARE METRIC

STIFFENER
BOX COVER
----------------------------------------------------------------REQ'D REQ'D
----REQ'D REQ'D
REQ'D REQ'D
REQ'D REQ'D
--REQ'D
REQ'D REQ'D
REQ'D REQ'D
--REQ'D
REQ'D REQ'D
REQ'D REQ'D
REQ'D REQ'D

To build catalog number:
1. For enclosure sizes ending in xx, select enclosure depth
for your application from column D. (i.e. -243008)

3. For Stainless Steel 304 enclosures add prefix CN4X.
(i.e. CN4X-243008)

2. For Stainless Steel 316L enclosures add prefix CN4X6.
(i.e. CN4X6-243008)

4. For Steel Powder Coated enclosures add prefix CN4.
(i.e. CN4-243008)

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

159

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 160

CN Series – Auxiliary Devices
Pilot Lights
II 2 G EEx de IIC
IEC 60529: IP66
Rated Operating Voltage: AC 24V, 48V, 110V, 230V; DC 24V, 48V
Lamp: Multi-LED
Electrical Life: 105 Hours Illuminated
Catalog Numbers
Red:
07-3353-1110/1000
Green:
07-3353-1120/2000
Yellow: 07-3353-1130/3000
White:
07-3353-1140/4000
Blue:
07-3353-1150/5000

Pushbuttons

3D–4

II 2 G EEx de IIC
IEC60529: IP66
Rated Insulation Voltage: 300V
Nominal Currents: 16A/+40°C, 11A/ +60°C
Catalog Numbers
Pushbuttons
Pushbutton, 1NO/1NC: 07-3323-1400/1000
Pushbutton, 2NO:
07-3323-1200/1000
Pushbutton, 2NC:
07-3323-1100/1000
* Pushbuttons are supplied with (4) loose colored discs: Red, Green,
Yellow, White

Mushroom Head Pushbuttons
Mushroom, Black, 1NO/1NC:
Mushroom, Black, 2NO:
Mushroom, Black, 2NC:
Mushroom, Black, Lockable, 1NO/1NC:
Mushroom, Black, Lockable, 2NO:
Mushroom, Black, Lockable, 2NC:

07-3323-1400/5000
07-3323-1200/5000
07-3323-1100/5000
07-3323-1400/6300
07-3323-1200/6300
07-3323-1100/6300

Emergency Stop Pushbuttons
II 2 G EEx de IIC
IEC 60529: IP66
Rated Insulation Voltage: 300V
Nominal Currents: 16A/+40°C, 11A/ +60°C
Catalog Numbers
1NO/1NC: 07-3323-1400/2000
2NO:
07-3323-1200/2000
2NC:
07-3323-1100/2000

160
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 161

CN Series – Auxiliary Devices
Selector Switches
II 2 G EEx de IIC
IEC 60529: IP66
Rated Insulation Voltage: 300V
Nominal Currents: 16A/+40°C, 11A/ +60°C

Catalog Numbers
Maintained Selector Switches
2-Position, 1NO/1NC: 07-3323-1400/3000
2-Position, 2NO:
07-3323-1200/3000
2-Position, 2NC:
07-3323-1100/3000
3-Position, 1NO/1NC: 07-3323-1400/4000
3-Position, 2NO:
07-3323-1200/4000
3-Position, 2NC:
07-3323-1100/4000

3D–5

Momentary (Left-Right) Selector Switches
3-Position, 1NO/1NC: 07-3323-1400/4100
3-Position, 2NO:
07-3323-1200/4100
3-Position, 2NC:
07-3323-1100/4100
Latching (Left) - Momentary (Right) Selector Switches
3-Position, 1NO/1NC: 07-3323-1400/4200
3-Position, 2NO:
07-3323-1200/4200
3-Position, 2NC:
07-3323-1100/4200
Momentary (Left) - Latching (Right) Selector Switches
3-Position, 1NO/1NC: 07-3323-1400/4300
3-Position, 2NO:
07-3323-1200/4300
3-Position, 2NC:
07-3323-1100/4300
Keyed Selector Switches (2 Position)
Lockable Both Positions, Key Removable Both Positions, 1NO/1NC:
07-3323-1400/6000
Lockable Both Positions, Key Removable Both Positions, 2NO:
07-3323-1200/6000
Lockable Both Positions, Key Removable Both Positions, 2NC:
07-3323-1100/6000
Lockable Depressed Position, Key Removable Depressed Position, 1NO/1NC: 07-3323-1400/6100
Lockable Depressed Position, Key Removable Depressed Position, 2NO:
07-3323-1200/6100
Lockable Depressed Position, Key Removable Depressed Position, 2NC:
07-3323-1100/6100
Lockable Initial Position, Key Removable Initial Position, 1NO/1NC:
07-3323-1400/6200
Lockable Initial Position, Key Removable Initial Position, 2NO:
07-3323-1200/6200
Lockable Initial Position, Key Removable Initial Position, 2NC:
07-3323-1100/6200

161
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 162

CN Series – Auxiliary Devices
Potentiometers
EEx de IIC
IEC 60529: IP66
Rated Voltage/Power: 250V / 1 Watt
1 Turn
Scale: 0 - 100%
Catalog Numbers
1 Watt, 1000 Ohm: GHG 418 8131 R0014
1 Watt, 4700 Ohm: GHG 418 8131 R0015
1 Watt, 10000 Ohm: GHG 418 8131 R0016

Measuring Instruments

3D–6

EEx e IIC
IEC 60529: IP66
Current Type: AC or DC
Movement: Moving Iron
Exactitude of Measurment: Class 2.5
Rated Current: Red Indicator
Zero Adjustment: Adjustment Screw on Instrument
Overload Range: 1 : 1.5 (indicated)

CATALOG NUMBERS
Movement
n / 1A
0 - 20 mA (Ri = 320 Ohm)
4 - 20 mA (Ri = 320 Ohm)
Other
Code for Movement:
1 = Direct Measurment
Code for Interchangeable Scales:
Direct Measurement:
Scale
Code
02
0 - 1 / 1.5 A
03
0 - 2.5 / 3.75 A
04
0 - 5 / 7.5 A
05
0 - 10 / 15 A
07
0 - 16 / 24 A
08
0 - 20 / 30 A

Scale
0 - 100 / 150 %
0 - 100 / 120 %
0 - 100 / 120 %

Catalog Number
GHG 412 8282 R0031
GHG 412 8285 R0033
GHG 412 8286 R0035

--

GHG 412 828___ R00___

2 = Instrument Transformer Connection, n / 1A

Interchangeable Scale:
Code
Scale
02
0 - 1 / 1.5 A
03
0 - 2.5 / 3.75 A
04
0 - 5 / 7.5 A
05
0 - 10 / 15 A
07
0 - 16 / 24 A
08
0 - 20 / 30 A

Code
09
10
11
12
13
14
15

Scale
0 - 30 / 45 A
0 - 40 / 60 A
0 - 50 / 75 A
0 - 60 / 90 A
0 - 75 / 112.5 A
0 - 100 / 150 A
0 - 150 / 225 A

Code
16
17
18
19
20
21

Scale
0 - 200 / 300 A
0 - 250 / 375 A
0 - 300 / 450 A
0 - 400 / 600 A
0 - 500 / 750 A
0 - 600 / 900 A

162
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 163

"B" (BOX OPENING)
30mm MINIMUM FROM
BOX OPENING OR STIFFENER
60mm MINIMUM BETWEEN
VERTICAL ROWS

110mm BETWEEN
VERTICAL ROWS
79mm BETWEEN METER
AND OPERATOR HOLE

60mm WIDE
DOOR STIFFENER
(SEE TABLE IF REQ'D)

60mm MINIMUM FROM
BOX OPENING OR STIFFENER

DIMENSIONS IN TABLE ARE METRIC

Cover Size
-1224
-1612
-1616
-1620
-2012
-2016
-2020
-2024
-2412
-2416
-2420
-2424
-2430
-3016
-3020
-3024
-3030
-3036
-3624
-3630
-3636
-4224
-4230
-4236
-4824
-4830
-4836
-6036

Box Opening
A
B
229
533
330
229
330
330
330
432
432
229
432
330
432
432
432
533
533
229
533
330
533
432
533
533
533
686
686
330
686
432
686
533
686
686
686
838
838
533
838
686
838
838
991
533
991
686
991
838
1143
533
1143
686
1143
838
1448
838

Door
Stiffener
---------------------YES
YES
YES
YES
YES
YES
YES

Max No. Of
Operator Rows
Horiz
Vert
2
8
4
3
4
5
4
7
5
3
5
5
5
7
5
8
7
3
7
5
7
7
7
8
7
11
9
5
9
7
9
8
9
11
9
13
11
8
11
11
11
13
13
6
13
10
13
12
15
6
15
10
15
12
20
12

Max No. Of
Operators
16
12
20
28
18
25
35
40
21
35
49
56
77
45
63
72
99
117
88
121
143
78
130
156
90
150
180
240

Max No. Of GHG
Type Meter Rows
Horiz
Vert
1
4
1
1
1
2
1
3
2
1
2
2
2
3
2
4
2
1
2
2
2
3
2
4
2
6
3
2
3
3
3
4
3
6
3
7
3
4
3
6
3
7
4
4
4
4
4
6
5
4
5
4
5
6
6
6

3D–7

106mm MINIMUM DISTANCE
FROM BOTTOM OF METER

133mm MINIMUM DISTANCE
FROM BOTTOM OF METER
TO OPERATOR

227mm
BETWEEN
METERS

148mm x 86mm
CUTOUT
120mm MINIMUM DISTANCE
FROM TOP OF METER
TO OPERATOR

70mm MINIMUM BETWEEN
HORIZONTAL ROWS

47mm MINIMUM FROM
BOX OPENING

ÿ30.5mm
OPERATOR HOLE
(SEE TABLE FOR
MAXIMUM QTY.)

"A" (BOX OPENING)

93mm MINIMUM DISTANCE
FROM TOP OF METER

CN Series – Cover Matrix

Max No. Of
GHG Type
Meters
4
1
2
3
2
4
6
8
2
4
6
8
12
6
9
12
18
21
12
18
21
16
16
24
20
20
30
36
163

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 164

Conduit/Cable & Wire Bending Guidelines
Table A - Minimum Spacing Between Centers of Conduit or Cable Entries

3D–8

SIZE

NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

NPT

METRIC

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

1/16 ~ 3/8

--

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

1-1/8
[29mm]

1/2

M16

4-3/8
[112mm]

3-5/8
[92mm]

3-3/8
3
[86mm] [77mm]

2-5/8
[68mm]

2-3/8
[61mm]

2
[51mm]

1-7/8
[48mm]

1-5/8
[42mm]

1-3/8
[35mm]

1-1/4
[32mm]

3/4

M20

4-1/2
[115mm]

3-3/4
[96mm]

3-1/2
3-1/8
[89mm] [80mm]

2-3/4
[70mm]

2-1/2
[64mm]

2-1/8
[54mm]

2
[51mm]

1-3/4
[45mm]

1-1/2
[38mm]

1

M25

4-5/8
[118mm]

3-7/8
[99mm]

3-5/8
3-1/4
[92mm] [83mm]

2-7/8
[74mm]

2-3/4
[70mm]

2-1/4
[58mm]

2-1/8
[54mm]

1-7/8
[48mm]

1-1/4

M32

4-7/8
[124mm]

4-1/8
[105mm]

3-7/8
[99mm

3-1/2
[89mm]

3-1/8
[80mm]

2-7/8
[74mm]

2-1/2
[64mm]

2-3/8
[61mm]

1-1/2

M40

5
[127mm]

4-1/4
4
3-5/8
[108mm] [102mm] [92mm]

3-1/4
[83mm]

3
[77mm]

2-5/8
[68mm]

2

M50

5-3/8
[137mm]

4-3/4
4-1/2
4
3-5/8
[121mm] [115mm] [102mm] [92mm]

3-3/8
[86mm]

2-1/2

M63

5-1/2
[140mm]

4-7/8
4-5/8
4-1/4
3-7/8
[124mm] [118mm] [108mm] [99mm]

3

M75

5-7/8
[150mm]

5-1/4
5
4-5/8
[134mm] [127mm] [118mm]

3-1/2

--

6-1/4
[159mm]

5-3/4
5-1/2
[147mm] [140mm]

4

--

6-7/8
[175mm]

6
[153mm]

5

--

7-3/8
[188mm]

This information is compiled from data which we believe is
reliable and is given in good faith. Since the methods of
application and condition under which our products are used are
beyond our control, we are not able to guarantee the application
and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box
NPT

5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

1/16 ~ 3/8

--

--

--

M75

M63

M50

M40

M32

M25

M20

M16

--

2-13/16
[72mm]

2-1/4
[58mm]

2
[51mm]

1-3/16
[31mm]

1
[26mm]

7/8
[23mm]

11/16
[18mm]

9/16
[14mm]

1/2
[13mm]

1/2
[13mm]

METRIC

1-3/4
1-7/16
[45mm] [37mm]

Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls
AWG

16

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

250

350

400

500

mm sq.

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

1-1/2
1-1/2 1-1/2 1-1/2
2
3
3-1/2
5-1/2
6
6-1/2
7
8-1/2
10
12
13
14
[38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm]
Notes:
1. The distances in Table A are recommended minimum
distances between centers of conduit and cable gland
entries. Consult manufacturer of conduit fitting or cable
glands for their recommended minimum spacing.
2. The distances in Table B are recommended minimum
distances between center of conduit and cable gland

entries to the edge of an opening or inside wall of box.
Consult manufacturer of conduit fitting or cable glands for
their recommended minimum spacing.
3. The distances in Table C are the minimum wire bending
space requirements between terminals, partitions, or inside
walls.

164
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 D 12/9/01 10:54 AM Page 165

CN Series – Enclosure Specification Sheet
Name:

Company:

Street/PO Box:

Phone:

City/State/Country/Zip:

Fax:

Enclosure Catalog Number:
Gland Plate(s):
Mounting Pan:
Breather/Drain:

❑ Top (-A)
❑ Steel, Powder Coated
❑ Breather

Nominal Working Voltage:

AC

❑ Bottom (-B)
❑ Stainless Steel
❑ Drain
V

❑ Left (-C)
❑ Aluminum
❑ Brass
DC

Auxiliary Devices

❑ Right (-D)
❑ Stainless Steel

V

Qty.

Tag

1:
2:

3D–9

3:
4:
5:
6:
7:
8:
9:
10:
Use Second Sheet For Additional Devices

2.5mm Terminal Blocks

Qty.

Conduit/Cable Entries:
Top Side

Qty.

Tag

Bottom Side

Qty.

Left Side

Qty.

Right Side

Qty.

1:
2:
3:
4:
5:
Use Second Sheet For Additional Devices

Enclosure Labeling:

165
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 E 12/9/01 10:56 AM Page 166

Intrinsically Safe Terminal Enclosures
Areas of Use
Zone Classified Areas - U.S., Canada, Europe
Intrinsically Safe 'ia': Zones 0, 1 and 2
Intrinsically Safe 'ib': Zones 1 and 2
Division Classified Areas - U.S.
Intrinsically Safe (2 fault): Class I, II, and III, Division 1
ATEX - EU Directive 94/9/EC
Equipment Groups I and II
Intrinsically Safe 'ia': Category 1GD or M1
Intrinsically Safe 'ib': Category 2GD or M2

Applicable Standards

3E–1

General Information

Europe: EN50014, EN50020

Adalet’s Intrinsically Safe Terminal Enclosures are available in
(33) standard enclosure sizes of Stainless Steel 316L, Stainless
Steel 304, Steel Powder Coated and Fiberglass Reinforced
Polyester materials. Adalet can also supply custom size
enclosures and terminal rail configurations to meet your
Intrinsically Safe applications. These enclosures are suitable
for areas where ignitable concentration of flammable gases,
vapors, liquids, and dusts can exists under normal operating
conditions. They are also ideal for indoor and outdoor areas
where dampness and highly corrosive atmospheres are
present such as refineries, water treatment, food processing,
coating, salt, and chemical facilities.

U.S.: UL2279 pt 11, ANSI/UL 913

Basic Principle of Intrinsically Safe
Intrinsic safety is intended for product in which the level of
electrical energy circulating or stored in the product is
insufficient to ignite a surrounding explosive atmosphere even
under fault conditions.
Note: No one device or wiring is intrinsically safe by itself
(except self-contained devices i.e. pagers, portable gas
detectors, etc.) but is intrinsically safe when incorporated into a
properly designed intrinsically safe system.

Canada: CSA-E79-0, CSA-E79-11
International: IEC60 079-0, IEC60 079-11

Key Design Features
Intrinsically Safe equipment must not be capable of
causing ignition of a surrounding explosive atmosphere
under specified conditions including:
two countable faults: Category 'ia'
one countable fault: Category 'ib'
Enclosures must provide at least IP20 protection in
accordance with EN60529, with higher levels of protection
required for certain applications. (i.e. an enclosure
containing intrinsically safe terminals and increased safety
terminals would require an increased safety enclosure 'e'
and minimum IP54 rating.)
Temperatures of wiring and small components must be
limited to the specified values according to the T-Class of
the equipment.
Separation of conductive parts must be achieved in terms
of specified clearances and creepage distances. Particular
attention is required for separation of intrinsically safe
circuits from non-intrinsicaly safe circuits.
Components on which intrinsic safety depends must be of
specified rating and construction.
Blue is the internationally recognized color for intrinsically
safe wiring and terminal blocks.

The Adalet Engineering Department is available to
assist in your Intrinsically Safe Terminal Enclosure
Selection

166
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 E 12/9/01 10:56 AM Page 167

Intrinsically Safe Terminal Enclosures - TSC & TFG Series
Options
Gland Plates (TSC Series Only):

Conduit/Cable Entries:

For enclosures with depths greater than 6”

Entries can be provided per a customer sketch or with
detailed information on the entry locations. Please refer to
Entry Spacing Tables at the end of the Increased Safety
Section in the CENELEC Product Catalog. Note: This
information is important and could affect the size of the
enclosure you selected.

These removable plates offer great flexibility for the end user to
drill holes without having to remove the entire enclosure from
the installation site.
Add the following Suffixes:
-A: Gland Plate installed on top of box.
-B: Gland Plate installed on bottom of box.
-C: Gland Plate installed on left of box.
-D: Gland Plate installed on right of box.
For multiple gland plates omit dashes
(i.e. TSC4X-101006-ABCD)

Close-up Plugs:
Any unused entries must be plugged with a Certified CloseUp Plug. Adalet can provide close-up plugs in various styles
and materials. Please indicate on the sketch or provide
detailed information of holes to be plugged.

EMC Shielding (TSC Series Only):

Enclosure Labeling:

EMC shielding is available on the TSC4X (SS304) and TSC4X6
(SS316L) enclosures with a shielding effectiveness of >50dB
through out the frequency range of 1MHz to 100MHz. For EMC
shielding add the prefix -EMC to the catalog text string,
immediately following the enclosure size.
(i.e. TSC4X-101006-EMC)
Note: This option is not available on enclosures with gland
plates installed.

Adalet can provide additional enclosure labeling with custom
silk screening or various colors of Lamacoid™ nameplates.
Please provide detailed information of the logo or text
required.

3E–2

For stainless steel enclosures only

Breather Drains:
Breather Drains can be provided per customer request.
They are available in Brass or Stainless Steel 316L. Please
indicate on a sketch or provide detailed information for
locations.

Hinged Cover (TFG Series Only):
A stainless steel piano type hinge is available by adding an H to
the end of the catalog string. (i.e. TFG-201407H)

Grounding Busbars:

Earthing Stud Assembly (TFG Series Only):

Some applications might require grounding points to be
terminated in the enclosure. With the use of a Ground
Busbar System this can be accomplished, consult factory for
options.

An Internal/External Earthing Stud can be provided upon
request. Please specify on the request for quote.

Mounting Pans:
As an alternative to the universal rail mounting system,
mounting pans are available in steel/powder coated, stainless
steel, and aluminum. Please indicate when requesting
quote.

Terminal Strip Assemblies:
Various options (i.e. marking tags, protective covers,
jumpers, partitions...) are available. Please provide detailed
information requesting quote.

167
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 E 12/9/01 10:56 AM Page 168

TSC Series - Intrinsically Safe Circuits
Certifications
0539
II 2GD
EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class II, Division 2
IEC60529: IP66
UL50: Type 4, 4X (Stainless Steel only), 12, & 13

D
Technical Details
Maximum Working Voltage: 600 Volts
Maximum Current: 5 Amps
Terminal Blocks: EN50019 Certified - Blue Colored

12

1

10

1

TSC4X6-060604I

For Enclosure
Dimensions see
Catalog Page
3B–48

18

1

14

1

TSC4X6-070704I

3B–49

22

1

19

1

TSC4X6-080804I

3B–50

32

1

27

1

TSC4X6-101006I

3B–51

32

1

27

1

TSC4X6-101008I

3B–52

42

1

35

1

TSC4X6-120604I

3B–53

42

1

35

1

TSC4X6-120605I

3B–54

42

1

35

1

TSC4X6-120805I

3B–55

42

1

35

1

TSC4X6-120806I

3B–56

84

2

70

2

TSC4X6-121206I

3B–57

84

2

70

2

TSC4X6-121208I

3B–58

114

2

96

2

TSC4X6-151506I

3B–59

114

2

96

2

TSC4X6-151508I

3B–60

124

2

104

2

TSC4X6-161206I

3B–61

124

2

104

2

TSC4X6-161208I

3B–62

180

3

150

3

TSC4X6-161606I

3B–63

180

3

150

3

TSC4X6-161608I

3B–64

2.5mm5 Terminals
Max. Qty.
# of Rows

SS316L Catalog Numbers

4mm5 Terminals
Max. Qty.
# of Rows

3E–3

1. All quantities shown are for terminal blocks installed in vertical rows.
2. For Stainless Steel 304 assemblies substitute TSC4X6 prefix with TSC4X prefix.
3. For Steel Powder Coated assemblies substitute TSC4X6 prefix with TSC4 prefix.
4. For Gland Plates (available only on enclosures with depths greater than 6 inches) add the following suffixes:
-A: Gland Plate installed on top of box
-B: Gland Plate installed on bottom of box
-C: Gland Plate installed on left of box
-D: Gland Plate installed on right of box
For multiple Gland Plates omit dashes. (i.e. TSC4X6-161608I-ABCD)

168
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 E 12/9/01 10:56 AM Page 169

TFG Series - Intrinsically Safe Circuits
Certifications
0539
II 2GD
EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Ex e II T6 (T5 Tamb +55°C)
Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C)
Class II, Division 2
IEC60529: IP66
UL50: Type 4X, 12, & 13

D
Technical Details
Maximum Working Voltage: 600 Volts
Maximum Current: 5 Amps

8

1

TFG-060604I

For Enclosure
Dimensions see
Catalog Page
3B–80

1

8

1

TFG-060606I

3B–81

1

18

1

TFG-080604I

3B–82

20

1

18

1

TFG-080606I

3B–83

30

1

25

1

TFG-100804I

3B–84

30

1

25

1

TFG-100806I

3B–85

40

1

35

1

TFG-121005I

3B–86

2.5mm5 Terminals
Max. Qty.
# of Rows
10

1

10
20

Catalog Numbers

4mm5 Terminals
Max. Qty.
# of Rows

40

1

35

1

TFG-121006I

3B–87

100

2

80

2

TFG-141206I

3B–88

100

2

80

2

TFG-141207I

3B–89

120

2

100

2

TFG-161406I

3B–90

120

2

100

2

TFG-161407I

3B–91

210

3

180

3

TFG-181608I

3B–92

210

3

180

3

TFG-181610I

3B–93

240

3

210

3

TFG-201608I

3B–94

240

3

210

3

TFG-201610I

3B–95

3E–4

Terminal Blocks: EN50019 Certified - Blue Colored

1. All quantities shown are for terminal blocks installed in vertical rows.

169
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.3 E 12/9/01 10:56 AM Page 170

Quick Reference Guide
METHODS OF PROTECTION
Area
Division 1

Division 2

Area
Zone 0
Zone 1

Zone 2

Protection Method

UL

CSA

CENELEC

Explosionproof
Intrinsically Safe
(2 Fault)
Purge/Pressurized
(Type X or Y)
Nonincendive
Non-sparking device
Purge/Pressurized
(Type Z)
Hermetically sealed
Any Class I,
Division 1 Method
Protection Method
Intrinsically Safe 'ia'
(2 Fault)
Flameproof 'd'
Increased Safety 'e'
Intrinsically Safe 'ib'
(1 Fault)0
Encapsulation 'm'
Oil Immersion 'o'
Purged/Pressurized 'p'
Powder filling 'q'
Any Zone 0 Method
Non-sparking 'nA'
Hermetically sealed 'nC'
Nonincendive 'nC'
Restricted breathing 'nR'
Any Zone 0 or 1 Method

ANSI/UL 1203

CSA-30

--

--

ANSI/UL 913

CSA-157

--

--

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604
UL 1604

CSA-213
CSA-213

---

---

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604

CSA-213

--

--

--

--

--

--

UL (AEx)

CSA (Ex)

CENELEC (EEx)

IEC (Ex)

UL 2279 Pt. 11

CSA-E79-18

EN 50028

IEC 60 079-18

UL 2279 Pt. 1
UL 2279 Pt. 7

CSA-E79-1
CSA-E79-7

EN 50018
EN 50019

IEC 60 079-1
IEC 60 079-7

UL 2279 Pt. 11

CSA-E79-11

EN 50020

IEC 60 079-11

UL 2279 Pt. 18
UL 2279
UL 2279 Pt. 2
UL 2279
-UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
--

CSA-E79-18
CSA-E79-6
CSA-E79-2
CSA-E79-5
-CSA-E79-15
CSA-E79-15
CSA-E79-15
CSA-E79-15
--

EN 50028
EN 50015
EN 50016
EN 50017
-prEN 50021
prEN 50021
prEN 50021
prEN 50021
--

IEC 60 079-18
IEC 60 079-6
IEC 60 079-2
IEC 60 079-5
-IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
--

TEMPERATURE CLASSES

AREA CLASSIFICATIONS
Ignitable Materials
Present Continuously

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Zone 0
(Zone 20 Dust)
Zone 0
Division 1

Zone 1
(Zone 21 Dust)
Zone 1
Division 1

Zone 2
(Zone 22 Dust)
Zone 2
Division 2

IEC/CENELEC
NEC 505
NEC 500

ATEX Classification by Group & Category According to Use
Ignitable Materials
Present Continuously
Equipment Group II Category 1 Equipment
(surface)
Equipment Group I
Category M1 Equipment
(mining)

IEC

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Category 2 Equipment

Category 3 Equipment

Category M2 Equipment

—

GAS GROUPINGS
Gas, Dust or Fiber

NEC 505/IEC/CENELEC

NEC 500

Acetylene
Hydrogen
Ethylene
Propane
Methane
Metal Dust
Coal Dust
Grain Dust
Fibers

Group IIC
Group IIC/Group IIB+H2
Group IIB
Group IIA
Group I (firedamp)
None
None
None
None

Class I/Group A
Class I/Group B
Class I/Group C
Class I/Group D
Class I/Group D
Class II/Group E
Class II/Group F
Class II/Group G
Class III

ACRONYMS
CENELEC - European Committee for Electrotechnical Standardization
IEC - International Electrotechnical Commission
NEC - National Electrical Code
U.L. - Underwriters Laboratories
C.S.A. - Canadian Standards Association
FM - Factory Mutual
BASEEFA - British Approvals Service for Electrical Apparatus in
Flammable Atmospheres
NFPA - National Fire Protection Agency
ISO - International Organization for Standardization
ANSI - American National Standard Institute
ATEX - Atmospheres Explosibles

Maximum
Surface
Temperature

NEC 505
IEC
CENELEC

450°C
300°C
280°C
260°C
230°C
215°C
200°C
180°C
165°C
160°C
135°C
120°C
100°C
85°C

T1
T2

T3

T4
T5
T6

NEC 500
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

INGRESS PROTECTION (IP XX) CODES
#

First Number
(Protection against Solid Bodies)

Second Number
(Protection against Liquids)

0
1
2
3
4
5
6
7
8

No protection
Objects greater than 50mm
Objects greater than 12mm
Objects greater than 2.5mm
Object greater than 1mm
Dust Protected
Dust-tight
---

No protection
Vertically dripping water
75-90 Deg. dripping water
Sprayed water
Splashed water
Water jets
Heavy seas
Effects of immersion
Indefinite immersion

15599 Sec.4 12/9/01 10:59 AM Page 171

XIH Explosionproof Instrument Housing

4A–1

Largest
Product Line
Available
Anywhere!

!
NEW
XIHMK 316SS & Aluminum 39/16" ID

XIHL & XDHL 4" ID Aluminum
XIHM 39/16" & 35/8" ID Aluminum
XDHM 35/8" ID Aluminum
XIH & XDH 33/16" ID Aluminum
XIHS 25/8" ID Aluminum
XDF Custom Digital Enclosure
(ATEX available on some models)

171
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 172

XIHMK Explosionproof Instrument Housing (316 Stainless or Aluminum)
3 9/16" ID Enclosure
Solid Cover Arrangements

Glass Cover Arrangements

4 1⁄4"

4 3⁄4"

3 9⁄16"
3 9⁄16"

3 5⁄16"

3 1⁄16"

Catalog
Number

Description

XIHMKFCX

Flat Cover 3⁄4" NPT Hubs

Catalog
Number

Description

XIHMKFGCX Flat Glass Cover 3⁄4" NPT Hubs

Standard Features
XIHMK housings accommodate large diameter assemblies,
multi-level circuit boards or wide angle readouts and displays.
The 3-9 ⁄ 16" ID provides maximum clearance to facilitate
instrument mounting, calibration or service. Precision
machined from sand-cast, copper-free aluminum.
XIHMK housings feature:

5"

5 5⁄32"

• 3⁄4" NPT conduit feed-through hubs offset
for maximum clearance and capacity
• 7⁄16" thick base for blind tapped instrument mounting holes
in any location

4A–2

• Glass cover models have a large 2-1/2" diameter, tempered
glass window for local read out
• 45° chamfer on window opening provides enhanced viewing
angle

51⁄ 2"

• Buna-N rubber gasket for NEMA 4X watertight applications

Certifications

• Front boss for use as additional conduit or sensor entry
• Corrosion resistant, “safety blue” polyester powder coating
(other colors available)

FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

• Internal and external ground screws and tamper resistant
cover set screw for extra safety

UL STANDARD 1203

• Stainless steel hardware

DEMKO CENELEC STANDARD EN 50014, 50018

Design Options
• Mounting lugs with 5⁄16" holes
• Additional small hole drilling and tapping in the backwall for
mounting of instrumentation

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

• 1⁄2" NPT or 3⁄4" NPT opening into back wall for conduit,
sensor or probe
• Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT; 1⁄2", 3⁄4" or 1"
NPSM; or 20mm or 25mm for sensor, probe or conduit
entry
• 1⁄2" NPT reducers are available – add suffix “2” to
catalog number

172
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 173

XIHL (Explosionproof Instrument Housing — Large)
4" ID Enclosure

Solid Cover Arrangements

Glass Cover Arrangements

5 1⁄8"

5 5⁄8"

4"

4"

3 3⁄4"

4"

Standard Features
Catalog
Number

Description

XIHLFCX

Flat Cover 3⁄4" NPT Hubs

Catalog
Number

XIHL housings accommodate large diameter
assemblies, multi-level circuit boards or wide
angle readouts and displays. The 4" ID provides
maximum clearance to facilitate instrument
mounting, calibration or service. Precision
machined from sand-cast copper-free aluminum.

Description

XIHLFGCX Flat Glass Cover 3⁄4" NPT Hubs

XIHL housings feature:
6"

7 1⁄8"

5 3⁄4"

7 5⁄8"

• 3⁄4" NPT conduit feed-through hubs offset
for maximum clearance and capacity
• 1⁄ 2" thick base for blind tapped instrument
mounting holes in any location

4"

• Glass cover models have a large 3 5⁄16"
diameter, tempered glass window for local
read out

4"

• Buna-N rubber gasket for NEMA 4X watertight
applications

Catalog
Number

Description

Catalog
Number

XIHLDCX

Dome Cover 3⁄4" NPT Hubs

XIHLDGCX

Description
Dome Glass Cover 3⁄4" NPT Hubs

4A–3

• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Internal and external ground screws and
tamper resistant cover set screw for
extra safety
• Stainless steel hardware

5 7⁄16"

Design Options
• Four 1⁄4–20 UNC holes in front boss for bracket
mounting
5"

5 5⁄8"

• Front Boss Modifications: 1⁄ 2" to 1" NPT, 1⁄ 2" to
3⁄4" NPSM or 20 mm for sensor, probe or
conduit entry. Consult factory for other sizes.
• 1⁄ 2" NPT reducers are available – add suffix “2”
to catalog number

Certifications

4 1⁄16"
5⁄16"

Diameter Mounting Lugs
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30
UL STANDARD 1203

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

KEMA CENELEC STANDARD EN 50014, 50018

173
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 174

XDHL (Explosionproof Double-Ended Housing — Large)
4" ID Enclosure

Solid Cover Arrangements

4"

4"

5"
4"

13⁄16"

Standard Features

2 1⁄8"

XDHL housings are designed to isolate incoming
power connections from instrumentation. The 4"
ID provides maximum clearance to facilitate
instrument mounting, calibration or service, with
back-to-back chambers separated by a solid, 1⁄ 2"
thick wall. Precision machined from sand-cast,
copper-free aluminum.

Glass Cover Arrangements

Catalog
Number

Description

XDHLFCX

Flat Cover 3⁄4" NPT Hubs

5 1⁄2"
3 3⁄4"

13⁄16"

2 1⁄8"

2 5⁄8"

Catalog
Number

2 5⁄8"

Description

XDHLFGCX Flat Glass Cover 3⁄4" NPT Hubs

XDHL housings feature:
• 3⁄4" NPT conduit feed-through hubs, offset into
power side for maximum clearance and capacity
• Front boss with 3⁄4" NPT opening into
instrument side for conduit, sensor or probe
(see design options for other sizes)

7"
71⁄2"
4"

4"

• Internal and external ground screws and tamper
resistant cover set screws for extra safety

6"

13⁄16"

• A choice of solid covers or 3 5⁄16" diameter
tempered glass window for local read out
and display

4A–4

2 1⁄8"

• Buna-N rubber gasket for NEMA 4X
watertight applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)

Catalog
Number

• Stainless steel hardware

13⁄16"

Catalog
Number

XDHLDCX Dome Cover 3⁄4" NPT Hubs

Design Options

2 1⁄8"

2 5⁄8"

Description

5 3⁄4"

Description

XDHLDGCX Dome Glass Cover 3⁄4" NPT Hubs

53⁄8"

• 2- to 12-point, power side terminal strip with
sealed pass-through to instrument (add suffix
“2T”, “4T”, “6T”, “8T”, “10T” or “12T” to
catalog number)

1 5⁄ 16"

• Internal wall can be modified (Drilled &
Tapped) to suit design needs – please consult
factory
• Power side cover options:
Flat Solid
Dome Glass
Flat Glass
Dome Solid

—
—
—
—

5 5⁄8"

Standard
Add Suffix “A”
Add Suffix “B”
Add Suffix “C”

• Front Boss Modifications: 1⁄ 2", 3 ⁄4" or 1" NPT;
1⁄ 2", 3 ⁄4" or 1" NPSM; or 20mm, 25mm or
30mm for sensor, probe or conduit entry

2 5⁄8"

2 1⁄4"

Certifications
FM STANDARD 3615

• 1⁄ 2" NPT reducers are available – add suffix “2”
to catalog number

CSA STANDARD C22.2 NO. 30

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIB+H2, IP66
NEMA 4X, 7BCD, 9EFG

UL STANDARD 1203

• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes)

KEMA CENELEC STANDARD EN 50014,50018

174
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 175

XIHM (Explosionproof Instrument Housing — Medium)
3 9/16" ID Enclosure (Standard)
3 5/8" ID Enclosure (Available - see note)
Solid Cover Arrangements

4 1⁄4"

Glass Cover Arrangements

*

4 3⁄4"

3 9⁄16"
3 9⁄16"

*

Standard Features

3 1⁄16"

XIHM housings accommodate large diameter
assemblies, multi-level circuit boards or wide
angle readouts and displays. The 3 9⁄16" ID
provides maximum clearance to facilitate
instrument mounting, calibration or service.
Precision machined from sand-cast, copper-free
aluminum.
XIHM housings feature:

* Midsize solid cover available –
add 11/16" to above dimensions.

*

Catalog
Number

Description

XIHMFCX

Flat Cover 3⁄4" NPT Hubs

XIHMMCX

Mid Size Cover
3/4" NPT Hubs

Catalog
Number

Description

XIHMFGCX Flat Glass Cover 3⁄4" NPT Hubs

6 3⁄8"
4 3⁄4"
6 11⁄16"
7 5⁄8"

3 9⁄16"

3 9⁄16"

Catalog
Number
Catalog
Number

Description

XIHMDCX

Dome Cover 3⁄4" NPT Hubs

Description

XIHMDGCX Dome Glass Cover 3⁄4" NPT Hubs

Design Options

5"

5 1⁄4"
4 5⁄8"

3 7⁄ 8"

Certifications
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

• 3⁄4" NPT conduit feed-through hubs offset
for maximum clearance and capacity
• 7⁄ 16" thick base for blind tapped instrument
mounting holes in any location
• Glass cover models have a large 2 5⁄8" diameter,
tempered glass window for local read out
• 60° chamfer on window opening provides
enhanced viewing angle
• Buna-N rubber gasket for NEMA 4X watertight
applications
• Front boss for bracket mounting or for use as
additional conduit or sensor entry
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Internal and external ground screws and tamper
resistant cover set screw for extra safety
• Stainless steel hardware

4A–5

3 5⁄16"

UL STANDARD 1203
DEMKO CENELEC STANDARD EN 50014, 50018

• Mounting lugs with 5⁄16" holes (add suffix “L”
to catalog number)
• Additional small hole drilling and tapping in the
backwall for mounting of instrumentation
• 1⁄2" NPT or 3⁄4" NPT opening into back wall for
conduit, sensor or probe
• Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT;
1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm for
sensor, probe or conduit entry
• Throat diameter can be increased to 3 5⁄8" –
please consult factory
• Glass window covers designed for Groups C
and D only (CENELEC: EExd IIB) are also
available – please consult factory for pricing
• 1⁄ 2" NPT reducers are available – add suffix “2”
to catalog number
• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes.)

175
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 176

XDHM (Explosionproof Double-Ended Housing — Medium)
3 5/8" ID Enclosure

Solid Cover Arrangements

3 5⁄8"

4 5⁄16"

Glass Cover Arrangements

*

* 3 5⁄16"

13⁄16"

4 13⁄16"

3 5⁄8"
3 1⁄16"

13⁄16"

Standard Features
XDHM housings are designed to isolate incoming
power connections from instrumentation. The 3 5⁄8"
ID provides maximum clearance to facilitate
instrument mounting, calibration or service, with
back-to-back chambers separated by a solid, 1⁄2"
thick wall. Precision machined from sand-cast,
copper-free aluminum.
XDHM housings feature:

4A–6

• 3⁄4" NPT conduit feed-through hubs, offset into
power side for maximum clearance and capacity
• Front boss with 3⁄4" NPT opening into
instrument side for conduit, sensor or probe
(see design options for other sizes)
• Internal and external ground screws and tamper
resistant cover set screws for extra safety
• A choice of solid covers or 2 5⁄8" diameter
tempered glass window for local read out
and display
• 60° chamfer on window opening provides
enhanced viewing angle
• Buna-N rubber gasket for NEMA 4X
watertight applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Stainless steel hardware

* 1 7⁄16"

*

• 2- to 8-point, power side terminal strip with
sealed pass-through to instrument (add suffix
“2T”, “4T”, “6T” or “8T” to catalog number)
• Internal wall can be modified (drilled & tapped) to
suit design needs - please consult factory
• Power side cover options:
—
—
—
—
—

Description

XDHMFCX

Flat Cover 3⁄4" NPT Hubs

XDHMMCX

Mid Size Cover
3/4" NPT Hubs

115⁄16"

Catalog
Number

Description

XDHMFGCX

Flat Glass Cover 3⁄4" NPT Hubs

*

6 7⁄16"
7 11⁄16"
3 5⁄8"
3 5⁄8"
13⁄16"

4 3⁄4"

6 11⁄16"

13⁄16"

*1 7⁄16"
*

1 7⁄16"

115⁄16"

Catalog
Number

Description

XDHMDCX

Dome Cover 3⁄4" NPT Hubs

115⁄16"

*

*
Catalog
Number

Description

XDHMDGCX Dome Glass Cover 3⁄4" NPT Hubs

5"

Standard
Add Suffix “A”
Add Suffix “B”
Add Suffix “C”
Add Suffix “D”

• Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT;
1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm
opening modify for sensor, probe or conduit
entry
• Glass window covers designed for Groups C
and D only (CENELEC: EExd IIB) are also
available – please consult factory for pricing
•

Catalog
Number

* 1 7⁄16"

*

* Midsize solid cover available –
add 11/16" to above dimensions.

Design Options

Flat Solid
Dome Glass
Flat Glass
Dome Solid
Midsize Solid

115⁄16"

5 1⁄4"

1 1⁄ 8"

2 1⁄4"

Certifications

1⁄ 2"

NPT reducers are available – add suffix “2”
to catalog number

FM STANDARD 3615

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

CSA STANDARD C22.2 NO. 30

• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes.)

UL STANDARD 1203
DEMKO CENELEC STANDARD EN 50014, 50018

176
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 177

XIH (Explosionproof Instrument Housing)
3 3/16" ID Enclosure

Solid Cover Arrangements

Glass Cover Arrangements

3 7⁄16"

3 3⁄16"

3 13⁄16"

3 3⁄16"

2 9⁄16"

Catalog
Number
XIHFCX2
XIHFCX3

2 3⁄16"

Catalog
Number

Description
Flat Cover 1⁄2" NPT Hubs
Flat Cover 3⁄4" NPT Hubs

4 15⁄16"

XIHFGCX2
XIHFGCX3

Description
Flat Glass Cover
Flat Glass Cover

5 13⁄16"

4 7⁄16"

3 3⁄16"

Standard Features

1⁄2" NPT Hubs
3⁄4" NPT Hubs

XIH housings are designed for small to medium
size electronic assemblies. The 3 3 ⁄16" ID
provides ample clearance to accommodate a
wide variety of measurement and control
devices. Precision machined from sand-cast
copper-free aluminum.
XIH housings feature:
6"

• Four interior mounting bosses at 45°
orientation accommodate blind tapped holes
on a 2 1⁄2" bolt circle
• 1⁄2" or 3 ⁄4" NPT conduit feed-through hubs,
offset for maximum clearance and capacity

3 3 ⁄16"

• Internal and external ground screws and
tamper resistant cover set screw for extra
safety

XIHDCX2
XIHDCX3

Catalog
Number

Description
Dome Cover
Dome Cover

1⁄2" NPT Hubs
3⁄4" NPT Hubs

XIHDGCX2
XIHDGCX3

• Glass cover models have a 2 5 ⁄8" diameter,
tempered glass window for local read out

Description
Dome Glass Cover 1⁄2" NPT Hubs
Dome Glass Cover 3⁄4" NPT Hubs

4A–7

Catalog
Number

• Buna-N rubber gasket for NEMA 4X watertight
applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Stainless steel hardware

4 1⁄2"

Design Options
• Four 1⁄4-20 UNC holes in front boss for bracket
mounting. Consult factory for other sizes.

4 1⁄8"
4 13⁄16"

• Front Boss Modifications: 1⁄2" or 3 ⁄4" NPT for
sensor, probe or conduit entry
• Mounting lugs with 5⁄16" holes (add suffix “L”
to catalog number)
• Other interior mounting bosses available –
please consult factory

3 1⁄4"

Certifications
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

UL STANDARD 1203 (Consult factory for availability)
ISSEP CENELEC STANDARD EN 50014, 50018

177
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 178

XDH (Explosionproof Double-Ended Housing)
3 3/16" ID Enclosure

Solid Cover Arrangements

3 3⁄16"
2 11⁄16"
3⁄4"

3⁄4"

1 5⁄16"

3 7⁄8"

3 3⁄16"

3 1⁄2"

2 5⁄16"

1 5⁄16"

17⁄8"

Standard Features
XDH housings are designed to isolate incoming
power connections from instrumentation. The
3 3⁄16" ID provides ample clearance to accommodate a wide variety of measurement and control
devices, with back-to-back chambers separated
by a solid, 3⁄8" thick wall. Precision machined from
sand-cast copper-free aluminum.
XDH housings feature:

Glass Cover Arrangements

17⁄8"

Catalog
Number

Description

Catalog
Number

Description

XDHFCX

Flat Cover 3⁄4" NPT Hubs

XDHFGCX

Flat Glass Cover 3⁄4" NPT Hubs

• 3⁄4" NPT conduit feed-through hubs, offset into
power side for maximum clearance and capacity

5 7⁄8"

• Front boss with 3⁄4" NPT opening into
instrument side for conduit, sensor or probe
(see design options for other sizes)

6 1⁄16"
3 3⁄16"

3 3⁄16"
3⁄4"

• Internal and external ground screws and tamper
resistant cover set screws for extra safety

5 1⁄16"

3⁄4"

1 5⁄16"

4A–8

• Buna-N rubber gasket for NEMA 4X watertight
applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Stainless steel hardware

1 5 ⁄16"

17⁄8"

• A choice of solid covers or 2 5⁄8" diameter
tempered glass window for local read out
and display

4 9⁄16"

17⁄8"

Catalog
Number

Description

Catalog
Number

Description

XDHDCX

Dome Cover 3⁄4" NPT Hubs

XDHDGCX

Dome Glass Cover 3⁄4" NPT Hubs

4 1⁄2"

Design Options
• 2- or 4-point, power side terminal strip with
sealed pass-through to instrument (add suffix
“2T” or “4T” to catalog number)

13⁄ 16"

4 11 ⁄16"

• Power side cover options:
Flat Solid
— Standard
Dome Glass — Add Suffix “A”
Flat Glass
— Add Suffix “B”
Dome Solid — Add Suffix “C”

2 1⁄4"

• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes.)
• Front Boss Modifications: 1⁄ 2" or 3⁄ 4" for sensor,
probe or conduit entry
• 1⁄ 2" NPT conduit entries are available – add
suffix “2” to catalog number.

Certifications

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

FM STANDARD 3615
CSA STANDARD C22.2 NO. 30
ISSEP CENELEC STANDARD EN 50014, 50018

178
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 179

XIHS (Explosionproof Instrument Housing — Small)
2 5/8" ID Enclosure
Cover
Arrangements
4"

3⁄16"

3 1 ⁄2"

3 1 ⁄2"

3 1 ⁄2"

Flat
Cover

Dome
Cover

Dome
Glass Cover

Catalog
Number

Base Styles

Conduit
Size
1⁄2"

“B”

XIHSBFC2
XIHSBFC3
XIHSBFC4
XIHSCFC2
XIHSCFC3
XIHSCFC4

1⁄2"

“C”

“D”

XIHSDFC3
XIHSDFC4

3⁄4"

XIHSLFC2
XIHSLFC3
XIHSLFC4

1⁄2"

“L”

“T”

XIHSTFC2
XIHSTFC3
XIHSTFC4

1⁄2"

XIHSXFC2
XIHSXFC3
XIHSXFC4

1⁄2"

“X”

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
1" NPT

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

XIHSYFC23 ONE 1⁄2" NPT
ONE 3⁄4" NPT

“Y”

2 5⁄8"

2 5⁄8"

2 5⁄8"

5 3⁄4"

Catalog
Number

Conduit
Size

Catalog
Number

Conduit
Size

XIHSBDC2
XIHSBDC3
XIHSBDC4

1⁄2"

XIHSBDGC2
XIHSBDGC3
XIHSBDGC4

1⁄2"

XIHSCDC2
XIHSCDC3
XIHSCDC4

1⁄2"

XIHSCDGC2
XIHSCDGC3
XIHSCDGC4

1⁄2"

XIHSDDC3
XIHSDDC4

3⁄4"

XIHSDDGC3
XIHSDDGC4

3⁄4"

XIHSLDC2
XIHSLDC3
XIHSLDC4

1⁄2"

XIHSLDGC2
XIHSLDGC3
XIHSLDGC4

1⁄2"

XIHSTDC2
XIHSTDC3
XIHSTDC4

1⁄2"

XIHSTDGC2
XIHSTDGC3
XIHSTDGC4

1⁄2"

XIHSXDC2
XIHSXDC3
XIHSXDC4

1⁄2"

XIHSXDGC2
XIHSXDGC3
XIHSXDGC4

1⁄2"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
1" NPT

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

XIHSYDC23 ONE 1⁄2" NPT
ONE 3⁄4" NPT

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
1" NPT

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

Standard Features
XIHS housings are designed to accommodate
small instruments or devices. The 2 5⁄8" ID
enclosure is offered in six different conduit
configurations and a choice of cover arrangements.
Precision machined from sand-cast, copper-free
aluminum.
XIHS housings feature:
•
•
•

•
•

3⁄4"

XIHSYDGC23 ONE 1⁄2" NPT
ONE 3⁄4" NPT

•

1⁄2", 3⁄4" or 1" NPT conduit feed-through hubs for
power
Internal ground screw
Interior instrument mounting bosses that
accommodate blind tapped holes on a
2" bolt circle
Glass cover arrangements with a 1 1⁄8" diameter tempered glass window for local read out
Buna-N rubber gasket for NEMA 4X watertight
applications
Tumblast, natural aluminum finish

Design Options
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)

Certifications

Note: Above dimensions are for 1/2" and 3/4" NPT. For 1" NPT
housings, add 5/16" to height dimensions.

FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

Class I, Groups B, C and D
Class II, Groups E,F,G
Class III
NEMA 4X, 7BCD, 9EFG

UL STANDARD 1203

E

A

C

E

E

A

C
D

D

B
F
“D”

“B”
CONDUIT
SIZE

A

B

C

D

E

F

1/2

3 1/2

2 1/16

2 5/8

1

11/16

7/8

7/8

3/4

3 1/2

2 1/16

2 5/8

1

11/16

7/8

7/8

1

3 1/2

2 3/8

2 5/8

1

1

2

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

179

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

4A–9

2 5⁄8"
1 11⁄16"

4 1⁄16"

5 1⁄16"

15599 Sec.4 12/9/01 10:59 AM Page 180

XDF Custom Enclosure Systems For Digital Instrumentation

Applications
Environments requiring explosionproof or dust-tight
enclosures.
Housing for panel mounted instrumentation with or
without external operator functions – can
accommodate standard DIN or other size devices.

Examples
• Flow Meters
• Level Indicators
• Motion Controllers
• Temperature Monitors
• Gas Analyzers

Features
• Space saving rectangular design
• Enclosure dimensions customized to match the
instrument
• A range of rectangular window openings
• Choice of quantity and location of miniature
operators including “key pad” configuration
• Front or rear accessibility for instrument service
• Watertight NEMA 4 gasketing
• Choice of surface finishes
• Recessed Allen Head cover bolts for appearance
and security

4B–1

• Special nameplating and escutcheon available.

Availability & Support
Adalet engineering will review your specific
requirements.
Adalet offers design support, custom dimensional
layout, product prototyping, testing and certification
assistance.
Production scheduling and inventory to match
defined needs.
Custom sizes available, consult factory for details.

Certifications
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

NEMA 4, 7CD, 9E, F & G
NEC Class I, Division I, Groups C & D
Class II, Groups E, F & G
NEMA 4, 7CD, 9E, F, & G

180
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 181

XCE & XJF Explosionproof Enclosures
XCE EXPLOSIONPROOF CONTROL ENCLOSURES
XJF EXPLOSIONPROOF JUNCTION BOXES FLANGED
Design Options
• CENELEC flameproof optional – designate XCEX when
ordering. Includes external earthing assembly.
• Quad-lead bolt (quick thread bolt) option - designate XCEQ
when ordering. Not available with XCEX.
• NEMA 4 (WATERTIGHT)/IP66:
Features a nitrile O-Ring retained in the cover flange in a
machined groove. When ordering, add N4 to the catalog number.
*This option may affect certifications - consult factory.
• NEMA 6 (SUBMERSIBLE):
Consult factory.
• Cast-on mounting buttons, bosses and pads:
Per customer specifications.
• Captive cover bolts:
Consult factory.
• Hinges:
May be installed for removable or non-removable cover.
Left side standard, other locations optional.
• Windows:
Circular window sizes ranging from 1" to 8" diameter viewing area.
Rectangular window sizes ranging from 3" x 3" to 13" x 13"
viewing area.
• Stainless steel cover bolts. Consult factory for NEMA 4X
rating.
• Mounting Pans:
Available in galvanized steel, aluminum or phenolic.

Applications:
Adalet XCE series and XJF enclosures are used in the
installation of electrical/electronic components for control,
measurement or monitoring applications in hazardous
environments. XCE control enclosures can be modified for
installation of a variety of explosionproof operator devices,
viewing windows and accessories permitting the development
of customized enclosure systems.

• Sidewall auxiliary device installation or machining available on
XCE/XCEQ/XCEX series enclosures – Consult Factory.
• Factory machined metric sidewall threads approved on XCE and
XCEX series for Groups C & D only.
• The Adalet engineering department is available to assist in the
selection of custom explosionproof enclosures for your products.

Features
• Integral, cast-on mounting lugs, slotted for ease of field
installation.

5A–1

• Copper-free aluminum, lightweight and corrosion resistant.

Certifications

• Uniform wall thickness for ease of installation of control
devices, windows and conduit openings.

XCE Series Control Enclosures

• External flange provides maximum accessibility of
components mounted inside.

UL STANDARD 1203
CSA STANDARD C22.2 NO. 30

• Tumblast finish for quality appearance.

EN 5O 018 (XCEX)

XJF Junction Boxes
CSA STANDARD C22.2 NO. 30
UL STANDARD 886

• Premium high strength steel cover bolts, plated and coated
for maximum corrosion resistance (stainless steel optional).
• Enclosures certified drillable for conduit entrances in the
factory or the field.

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIB, (Specify XCEX)
ATEX Certifications available – Consult Factory.
NEMA 4, 7B*CD, 9EFG

• Internal grounding screw standard.
• Covers exceeding approximately 75 lbs. are provided with two
removable eye bolts for ease of handling.

Some sizes and option combinations may not be certified.
Consult Factory for specific certifications and file numbers.

• XCE/XCEQ/XCEX certified drillable for operators at the factory
or in the field.
• IP40 standard on XCEX without gasket.
ADALET Enclosure Systems • Designing Our Products Around Yours

181
SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 182

XCE & XJF Explosionproof Enclosures
XCE/XJF
Catalog
Number

Inside Nominal
Dimensions
W
L
D

Usable
Inside
Depth

Mtg.
Bolt
Size

Apprx.
Shipping
Weight, lbs.

041604

4

16

4

4 3/4

7 1/4

19 1/4

6

12 1/8

6 3/4

3/8

25

060804

6

8

4

4 5/8

9 1/4

11 1/4

5 15/16

060805

6

8

5

5 5/8

9 1/4

11 1/4

6 15/16

4 1/2

9 1/8

3/8

21

4 1/2

9 1/8

3/8

23

060806

6

8

6

6 5/8

9 1/4

11 1/4

061105

6

11

5

5 7/8

9 1/4

14 1/4

7 15/16

4 1/2

9 1/8

3/8

25

7 3/16

7 1/2

9 1/8

3/8

24

061204

6

12

4

4 3/4

9 1/4

061206

6

12

6

6 3/4

9 1/4

15 1/4

6 1/16

8 1/2

9 1/8

3/8

24

15 1/4

8 1/16

8 1/2

9 1/8

3/8

29

061305

6

13

5

5 7/8

9 1/4

16 1/4

7 3/16

9 1/2

9 1/8

3/8

26

071004

7

10

4

4 3/4

10 3/8

13 3/8

6 3/16

6 1/2

9 3/4

3/8

27

071006

7

10

6 1/8

6 3/4

10 3/8

13 3/8

8 3/16

6 1/2

9 3/4

3/8

31

071805

7

18 1/4

5

5 3/4

10 3/8

21 5/8

7 3/16

14 1/2

9 3/4

3/8

55

080804

8

8

4

4 13/16

11 3/8

11 3/8

6 3/8

4 1/4

11

3/8

24

080806

8

8

6

6 13/16

11 3/8

11 3/8

8 3/8

4 1/4

11

3/8

28

080808

8

8

8

8 13/16

11 3/8

11 3/8

10 3/8

4 1/4

11

3/8

35

081004

8

10

4

4 3/4

11 3/8

13 3/8

6 1/4

6 1/2

10 3/4

3/8

30

081006

8

10

6

6 3/4

11 3/8

13 3/8

8 1/4

6 1/2

10 3/4

3/8

34

Overall Dimension
A
B
C

Mounting Lug
CL to CL
E
F

081008

8

10

8

8 3/4

11 3/8

13 3/8

10 1/4

6 1/2

10 3/4

3/8

39

081204

8

12

4

4 3/4

11 3/8

15 3/8

6 1/4

8 1/2

10 3/4

3/8

34

081206

8

12

6

6 3/4

11 3/8

15 3/8

8 1/4

8 1/2

10 3/4

3/8

42

081208

8

12

8

8 3/4

11 3/8

15 3/8

10 1/4

8 1/2

10 3/4

3/8

48

091105

9

11

5

5 3/4

12 3/8

14 3/8

7 5/16

7 1/2

12

3/8

41

101004

10

10

4

4 3/4

13 3/8

13 3/8

6 5/16

6 1/2

13

3/8

34

• To indicate Quad-Lead bolt
option, add suffix "Q" after XCE.
(Not available on XCEX models.)

101006

10

10

6

6 3/4

13 3/8

13 3/8

8 5/16

6 1/2

13

3/8

44

101008

10

10

8

8 3/4

13 3/8

13 3/8

10 5/16

6 1/2

13

3/8

50

• Operators, windows and hinges
are ordered separately.

101206

10

12

6 1/4

7 1/4

13 3/8

15 3/8

8 7/8

8 1/2

13 1/4

3/8

46

101404

10

14

4

4 3/4

13 3/8

17 3/8

6 7/16

10 5/8

13 1/4

3/8

42

• To indicate EEx d approval
specify XCEX.

101406

10

14

6

6 3/4

13 3/8

17 3/8

8 7/16

10 5/8

13

3/8

49

101408

10

14

8

8 3/4

13 3/8

17 3/8

10 1/2

10 5/8

13

3/8

57

101410

10

14

8

10 13/16 13 3/8

17 3/8

12 7/16

10 5/8

13

3/8

70

121204

12

12

4

5

16 1/4

16 1/4

6 15/16

8 5/8

15 3/4

1/2

60

121206

12

12

6

7

16 1/4

16 1/4

8 15/16

8 5/8

15 3/4

1/2

68

121208

12

12

8

9

16 1/4

16 1/4

10 15/16

8 5/8

15 3/4

1/2

80

121804

12

18

4

4 3/4

16 1/4

22 1/4

6 3/4

14 1/8

15 3/4

1/2

85

121806

12

18

6

6 3/4

16 1/4

22 1/4

8 3/4

14 1/8

15 3/4

1/2

93

121808

12

18

8

8 3/4

16 1/4

22 1/4

10 3/4

14 1/8

15 3/4

1/2

101

122005

12

20

5

5 3/4

16 1/4

24 1/4

8 1/8

14 3/8

15 3/4

1/2

104

122404

12

24

4

4 15/16

16 1/4

28 1/4

7 1/4

18 3/8

15 3/4

1/2

116

122406

12

24

6

6 15/16

16 1/4

28 1/4

9 1/4

18 3/8

15 3/4

1/2

127

• To indicate NEMA 4/IP66 option,
add suffix “N4” after size
(catalog number).

5A–2

Note: All dimensions are in inches
and are nominal enclosure size
only. Inside nominal dimensions
are at flange. Consult factory for
exact dimensions.

*

*Approval Pending – Consult Factory.

182
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 183

XCE & XJF Explosionproof Enclosures

*
*
*
*

*
*

Inside Nominal
Dimensions
W
L
D

Usable
Inside
Depth

122408

12

24

8

8 15/16

122410

12

24

123006

12

30

123604

12

123606

12

123608
124608

Mounting Lug
CL to CL
E
F

Overall Dimension
A
B
C
16 1/4

15 3/4

Mtg.
Bolt
Size

Apprx.
Shipping
Weight, lbs.

1/2

140

28 1/4

11 1/4

18 3/8

10 10 15/16 16 1/4

28 1/4

13 1/4

18 3/8

15 3/4

1/2

154

6

6 11/16

16 3/4

34 1/4

9 5/8

23

15 3/4

1/2

180

36

4

4 15/16

16 1/4

40 1/4

7 11/16

29

15 3/4

1/2

192

36

6

6 15/16

16 1/4

40 1/4

9 11/16

29

15 3/4

1/2

212

12

36

8

8 15/16

16 1/4

40 1/4

11 11/16

29

15 3/4

1/2

232

12

46

8

8 15/16

16 1/4

50 1/4

11 11/16

39

15 3/4

5/8

280

141404

14

14

4

5

18 1/4

18 1/4

7 1/8

9 3/4

17 3/4

1/2

91

141406

14

14

6

7

18 1/4

18 1/4

9 1/4

9 3/4

17 3/4

1/2

97

141408

14

14

8

9

18 1/4

18 1/4

11 1/8

9 3/4

17 3/4

1/2

103

142210

14

22

10

11 1/4

18 1/4

26 1/4

13 5/8

16 1/2

17 3/4

1/2

181

142213

14

22

10

13

18 1/4

26 1/4

15 1/8

16 1/2

17 3/4

1/2

235

142806

14

28

6

7 13/16

18 1/4

32 1/4

9 9/16

22 1/2

17 3/4

1/2

120

161604

16

16

4

6 5/8

20 7/8

20 7/8

7 15/16

11

19 3/4

5/8

114

161606

16

16

6

7 5/8

20 7/8

20 7/8

9 15/16

11

19 3/4

5/8

135

161608

16

16

8

9 5/8

20 7/8

20 7/8

11 15/16

11

19 3/4

5/8

156

162406

16

24

6

7 13/16

20 7/8

28 7/8

10 3/8

18 3/8

19 3/4

5/8

190

162408

16

24

8

9 13/16

20 7/8

28 7/8

12 3/8

18 5/8

19 3/4

5/8

209

162410

16

24

10 11 13/16 20 7/8

28 7/8

14 3/8

18 3/8

19 3/4

5/8

225

162806

16

28

6

6 13/16

20 1/2

32 11/16

9 1/2

22 1/2

19 3/4

5/8

200

163406

16

34

6

6 15/16

20 1/2

38 1/2

9 1/2

27

19 3/4

5/8

260

163010

16

30

10

11 1/8

20 1/2

34 1/2

13 7/8

27

19 3/4

5/8

320

164610

16

46

10 11 13/16 20 7/8

50 7/8

14 9/16

39

19 3/4

5/8

390

181804

18

18

4

5 13/16

22 7/8

22 7/8

8 1/2

13

21 3/4

5/8

154

181806

18

18

6

7 13/16

22 7/8

22 7/8

10 1/2

13

21 3/4

5/8

177

181808

18

18

8

9 13/16

22 7/8

22 7/8

12 1/2

13

21 3/4

5/8

200

182406

18

24

6

7 7/16

22 7/8

28 7/8

10 13/16

18 3/8

21 3/4

5/8

226

182408

18

24

8

9 7/16

22 7/8

28 7/8

12 13/16

18 3/8

21 3/4

5/8

239

182410

18

24

10

11 7/16

22 7/8

28 7/8

14 13/16

18 3/8

21 3/4

5/8

260

183008

18

30

8

9 3/8

22 7/8

34 7/8

12 13/16

23

21 3/4

5/8

293

183608

18

36

8

9 3/8

22 7/8

40 7/8

12 7/8

29

21 3/4

5/8

318

183610

18

36

10

11 3/8

22 7/8

40 7/8

14 7/8

29

21 3/4

5/8

340

203606

20

36

6

7 1/8

24 7/8

40 7/8

10 7/8

29

24

5/8

340

203612

20

36

6

12

25 5/8

41 5/8

15

29

24

5/8

415

204806

20

48

6

7 1/8

24 7/8

52 7/8

10 7/8

41

24

5/8

430

204812

20

48

6

12

25 5/8

53 5/8

15

41

24

5/8

515

242408

24

24

8

9 7/16

28 7/8

28 7/8

12 7/16

18 3/8

28

5/8

302

242410

24

24

10

11 7/16

28 7/8

28 7/8

14 7/16

18 3/8

28

5/8

330

243008

24

30

8

9 1/4

28 7/8

34 7/8

12 15/16

23

28

5/8

356

243608

24

36

8

9 1/4

28 7/8

40 7/8

12 7/16

29

28

5/8

408

243610

24

36

10

11 1/4

28 7/8

40 7/8

14 7/8

29

28

5/8

433

243612

24

36

10

12

28 7/8

40 7/8

16 1/2

29

28

5/8

545

323612

32

36

6

12

37 3/4

41 3/4

15 1/2

29

36 1/8

5/8

691

• To indicate Quad-Lead bolt
option, add suffix "Q" after XCE.
(Not available on XCEX models.)
• Operators, windows and hinges
are ordered separately.
• To indicate EEx d approval
specify XCEX.
• To indicate NEMA 4/IP66 option,
add suffix “N4” after size
(catalog number).
Note: All dimensions are in inches
and are nominal enclosure size
only. Inside nominal dimensions
are at flange. Consult factory for
exact dimensions.
*Approval Pending – Consult Factory.

183
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

5A–3

*
*

XCE/XJF
Catalog
Number

15599 Sec.5 A 12/11/01 6:06 PM Page 184

Bolt-On Mounting Lugs for XCE & XJF Enclosures
Adjust To Irregular Mounting Surfaces
Without Damaging Enclosures

Adalet Bolt-On Mounting Lugs for XCE and XJF Enclosures
are bi-directional, permitting either vertical or horizontal
mounting orientation. The ductile aluminum alloy lugs adapt
to irregular surfaces so lug bolts can be tightened without
damaging the enclosure.

5A–4
184
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 185

Bolt-On Mounting Lugs
Catalog
Number

Mounting Dimensions
Optional Mounting
Standard Mounting
J
K
L
M

Mtg. Lug
Size
N

Mtg. Lug
Thickness
T

Catalog
Number

Mounting Dimensions
Optional Mounting
Standard Mounting
J
K
L
M

Mtg. Lug
Size
N

Mtg. Lug
Thickness
T

X

X

7 7/8

4

3/8

1/4

XCE124608M

7

49

15

41

1/2

3/8

XCE060805M

X

X

7 7/8

4

3/8

1/4

XCE141404M

9

17

17

9

1/2

3/8

XCE060806M

X

X

7 7/8

4

3/8

1/4

XCE141406M

9

17

17

9

1/2

3/8

XCE061105M

X

X

7 7/8

9

3/8

1/4

XCE141408M

9

17

17

9

1/2

3/8

XCE061204M

X

X

7 7/8

10

3/8

1/4

XCE142806M

9

31

17

23

1/2

3/8

XCE061206M

X

X

7 7/8

10

3/8

1/4

XCE161604M

11

19

19

10 15/16

1/2

3/8

XCE061305M

X

X

7 7/8

11

3/8

1/4

XCE161606M

11

19

19

10 15/16

1/2

3/8

XCE071004M

X

X

8 7/8

8

3/8

1/4

XCE161608M

11

19

19

10 15/16

1/2

3/8

XCE071006M

X

X

8 7/8

8

3/8

1/4

XCE162406M

11 3/8

27 1/4

19 3/8

19 3/8

1/2

3/8

XCE071805M

X

X

8 7/8

16

3/8

1/4

XCE162408M

11 3/8

27 1/4

19 3/8

19 3/8

1/2

3/8

XCE080804M

X

X

9 7/8

6

3/8

1/4

XCE162410M

11 3/8

27 1/4

19 3/8

19 3/8

1/2

3/8

XCE080806M

X

X

9 7/8

6

3/8

1/4

XCE162806M

11 3/8

31 3/8

19 3/8

23

1/2

3/8

XCE080808M

X

X

9 7/8

6

3/8

1/4

XCE163406M

11 3/8

37 3/8

19 3/8

29 3/8

1/2

3/8

XCE081004M

X

X

9 7/8

8

3/8

1/4

XCE164610M

11 3/8

49 3/8

19 3/8

41 3/8

1/2

3/8

XCE081006M

X

X

9 7/8

8

3/8

1/4

XCE181804M

13 3/8

21 3/8

21 3/8

13 3/8

1/2

3/8

XCE081008M

X

X

9 7/8

8

3/8

1/4

XCE181806M

13 3/8

21 3/8

21 3/8

13 3/8

1/2

3/8

XCE081204M

3 13 /16

14 3/8

10 3/8

7 13/16

1/2

3/8

XCE181808M

13 3/8

21 3/8

21 3/8

13 3/8

1/2

3/8

XCE081206M

3 13 /16

14 3/8

10 3/8

7 13/16

1/2

3/8

XCE182406M

13

27

21

19

1/2

3/8

XCE081208M

3 13 /16

14 3/8

10 3/8

7 13/16

1/2

3/8

XCE182408M

13

27

21

19

1/2

3/8

XCE091105M

4 13/16

13 3/8

11 3/8

9

1/2

3/8

XCE182410M

13

27

21 1/4

19

1/2

3/8

XCE101004M

5

13

13

5

1/2

3/8

XCE183008M

13

31

21

25

1/2

3/8

XCE101006M

5

13

13

5

1/2

3/8

XCE183608M

13 1/4

39 1/2

21

31 1/2

1/2

3/8

XCE101008M

5

13

13

5

1/2

3/8

XCE183610M

13 1/4

39 1/2

21 1/4

31 1/2

1/2

3/8

XCE101206M

5

15

13

6

1/2

3/8

XCE203606M

15 3/4

39 3/4

23 3/4

31 3/4

1/2

3/8

XCE101404M

5

17

13

9

1/2

3/8

XCE204806M

15 3/4

51 3/4

23 3/4

43 3/4

1/2

3/8

XCE101406M

5

17

13

9

1/2

3/8

XCE242408M

19 1/2

27 1/2

27 1/2

19 1/2

1/2

3/8

XCE101408M

5

17

13

9

1/2

3/8

XCE242410M

19 1/2

27 1/2

27 1/2

19 1/2

1/2

3/8

XCE101410M

5

17

13

9

1/2

3/8

XCE243008M

19 9/16

33 9/16

27 9/16

25 9/16

1/2

3/8

XCE121204M

7

15

15

7

1/2

3/8

XCE243608M

19 9/16

39 9/16

27 9/16

31 9/16

1/2

3/8

XCE121206M

7

15

15

7

1/2

3/8

XCE243610M

19 9/16

39 9/16

27 9/16

31 9/16

1/2

3/8

XCE121208M

7

15

15

7

1/2

3/8

XCE121804M

7

20 7/8

15

12 7/8

1/2

3/8

XCE121806M

7

20 7/8

15

12 7/8

1/2

3/8

XCE121808M

7

20 7/8

15

12 7/8

1/2

3/8

XCE122005M

7

22 7/8

15

14 7/8

1/2

3/8

XCE122404M

7

26 7/8

15

18 7/8

1/2

3/8

XCE122406M

7

26 7/8

15

18 7/8

1/2

3/8

XCE122408M

7

26 7/8

15

18 7/8

1/2

3/8

XCE122410M

7

26 7/8

15

18 7/8

1/2

3/8

XCE123006M

7

33

15

24 7/8

1/2

3/8

XCE123604M

7

39

15

31

1/2

3/8

XCE123606M

7

39

15

31

1/2

3/8

XCE123608M

7

39

15

31

1/2

3/8

5A–5

XCE060804M

185
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 186

XCE Series Recommended Spacing For Operators In Covers

Catalog
Number

Standard Operators
Maximum Maximum
Maximum Number
Number Recommended
Number
Operator
Operators
Spacing
Operators
Rows
Per Row
CL to CL

Miniature Operators
Maximum Maximum
Maximum Number
Number
Number Operator
Operators
Operators
Rows
Per Row

Recommended
Spacing
CL to CL

Cover
Wall
Thickness
(Inches)

XCE041604

5

5

1

2 1/2

13

13

1

1

1/2

XCE060804

2

2

1

2 1/2

8

4

2

1

1/2

XCE060805

2

2

1

2 1/2

8

4

2

1

1/2

XCE060806

2

2

1

2 1/2

8

4

2

1

1/2

XCE061105

3

3

1

2 1/2

14

7

2

1

1/2

XCE061204

4

4

1

2 1/2

16

8

2

1

5/8

XCE061206

4

4

1

2 1/2

16

8

2

1

5/8

XCE061305

4

4

1

2 1-2

18

9

2

1

1/2

XCE071004

6

3

2

2 1/2

18

6

3

1

5/8

XCE071006

6

3

2

2 1/2

18

6

3

1

5/8

XCE071805

12

6

2

2 1/2

45

15

3

1

5/8

XCE080804

4

2

2

2 1/2

16

4

4

1

11/16

XCE080806

4

2

2

2 1/2

16

4

4

1

11/16

XCE080808

4

2

2

2 1/2

16

4

4

1

11/16

XCE081004

6

3

2

2 1/2

24

6

4

1

11/16

XCE081006

6

3

2

2 1/2

24

6

4

1

11/16

XCE081008

6

3

2

2 1/2

24

6

4

1

11/16

XCE081204

8

4

2

2 1/2

32

8

4

1

11/16

XCE081206

8

4

2

2 1/2

32

8

4

1

11/16

XCE081208

8

4

2

2 1/2

32

8

4

1

11/16

XCE091105

6

3

2

2 1/2

35

7

5

1

11/16

XCE101004

9

3

3

2 1/2

36

6

6

1

11/16

XCE101006

9

3

3

2 1/2

36

6

6

1

11/16

5A–6

XCE101008

9

3

3

2 1/2

36

6

6

1

11/16

XCE101206

12

4

3

2 1/2

48

8

6

1

3/4

XCE101404

12

4

3

2 1/2

60

10

6

1

3/4

XCE101406

12

4

3

2 1/2

60

10

6

1

3/4

XCE101408

12

4

3

2 1/2

60

10

6

1

3/4

XCE101410

12

4

3

2 1/2

60

10

6

1

3/4

XCE121204

9

3

3

3

64

8

8

1

7/8

XCE121206

9

3

3

3

64

8

8

1

7/8

XCE121208

9

3

3

3

64

8

8

1

7/8

XCE121804

15

5

3

3

92

14

8

1

15/16

XCE121806

15

5

3

3

92

14

8

1

15/16

XCE121808

15

5

3

3

92

14

8

1

15/16

XCE122005

18

6

3

3

128

16

8

1

1 1/8

XCE122404

21

7

3

3

150

20

8

1

1 1/8

XCE122406

21

7

3

3

150

20

8

1

1 1/8

XCE122408

21

7

3

3

150

20

8

1

1 1/8

Note: Closer spacing other than 21/2 & 3 inches available – Consult factory for special designs.

186
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 187

Catalog
Number

Standard Operators
Maximum Maximum
Maximum Number
Number Recommended
Number
Operator
Operators
Spacing
Operators
Rows
Per Row
CL to CL

XCE122410

21

XCE123006
XCE123604

Miniature Operators
Maximum Maximum
Maximum Number
Number
Number Operator
Operators
Operators
Rows
Per Row

Recommended
Spacing
CL to CL

Cover
Wall
Thickness
(Inches)
1 1/8

7

3

3

150

20

8

1

27

9

3

3

150

26

8

1

1 3/8

33

11

3

3

150

32

8

1

1 3/16

XCE123606

33

11

3

3

150

32

8

1

1 3/16

XCE123608

33

11

3

3

150

32

8

1

1 3/16

XCE124608

42

14

3

3

150

41

8

1

1 1/4

XCE141404

16

4

4

3

100

10

10

1

7/8

XCE141406

16

4

4

3

100

10

10

1

7/8

XCE141408

16

4

4

3

100

10

10

1

7/8

XCE142210

24

6

4

3

100

18

10

1

1 1/8

XCE142213

24

6

4

3

100

18

10

1

1 1/8

XCE142806

32

8

4

3

150

24

10

1

1 1/8

XCE161604

16

4

4

3 1/2

121

11

11

1

7/8

XCE161606

16

4

4

3 1/2

121

11

11

1

7/8

XCE161608

16

4

4

3 1/2

121

11

11

1

7/8

XCE162406

24

6

4

3 1/2

150

19

11

1

7/8

XCE162408

24

6

4

3 1/2

150

19

11

1

7/8

XCE162410

24

6

4

3 1/2

150

19

11

1

7/8

XCE162806

28

7

4

3 1/2

150

24

11

1

1 1/4

XCE163010

32

8

4

3 1/2

150

26

12

1

1 1/4

XCE163406

32

8

4

3 1/2

150

30

11

1

1 1/4

XCE164610

48

12

4

3 1/2

150

41

11

1

1

XCE181804

16

4

4

3 1/2

150

13

13

1

1

XCE181806

16

4

4

3 1/2

150

13

13

1

1

XCE181808

16

4

4

3 1/2

150

13

13

1

1

XCE182406

24

6

4

3 1/2

150

19

13

1

1 1/2

XCE182408

24

6

4

3 1/2

150

19

13

1

1 1/2

XCE182410

24

6

4

3 1/2

150

19

13

1

1 1/2

XCE183008

32

8

4

3 1/2

150

25

13

1

1 1/2

XCE183608

36

9

4

3 1/2

150

31

13

1

1 7/8

XCE183610

36

9

4

3 1/2

150

31

13

1

1 7/8

XCE203606

45

9

5

3 1/2

150

31

15

1

1 7/8

XCE203612

45

9

5

3 1/2

150

31

15

1

1 3/8

XCE204806

65

13

5

3 1/2

150

43

15

1

1 7/8

XCE204812

65

13

5

3 1/2

150

43

15

1

1 3/8

XCE242408

36

6

6

3 1/2

150

19

19

1

1 1/2

XCE242410

36

6

6

3 1/2

150

19

19

1

1 1/2

XCE243008

42

7

6

3 1/2

150

25

19

1

1 7/8

XCE243608

54

9

6

3 1/2

150

31

19

1

1 7/8

XCE243610

54

9

6

3 1/2

150

31

19

1

1 7/8

XCE243612

54

9

6

3 1/2

150

31

19

1

1 3/8

XCE323612

72

9

8

3 1/2

150

31

27

1

1 3/8

5A–7

XCE Series Recommended Spacing For Operators In Covers

Note: Closer spacing other than 3 & 31/2 inches available – Consult factory for special designs.

187
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 188

XCE & XJF Explosionproof Enclosures

5A–8
188
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 189

Conduit Drilling and Tapping Guidelines
When drilling & tapping enclosures for conduit, proper installation requires compliance with the following:
1. Must be tapped with at least 5 full NPT threads (XCEX requires six NPT threads) in enclosure back
or sides only; min. 1/2" conduit size.
2. Tapping depth of NPT holes must be plus 1/2 turn min. to plus 1-1/2 turns max. past standard NPT plug gage notch.
3. Inner end of conduit openings shall be smooth and well-rounded.

TABLE I
Thread Size Of

Minimum wall thickness at conduit entrance excluding XCEX

Conduit, Inches (NPT)

Explosionproof

1/2 - 3/4

3/8 inch

Dust Ignition Proof / Weather Proof
1/4 inch

1-2

7/16 inch

5/16 inch

2 1/2 - 5

5/8 inch

7/16 inch

TABLE II
Conduit size, inches (NPT)

1/2

3/4

1

1 1/4

1 1/2

2

2 1/2

3

3 1/2

4

5

Minimum Distance from conduit CL
to inside corner or back of box

1 5/16

1 7/16

1 9/16

1 3/4

1 7/8

2 1/8

2 3/8

2 11/16

2 15/16

3 1/4

3 7/8

Approximate diameter of union

1 7/8

1 7/8

2 1/16

2 7/8

3 1/4

3 7/8

4 7/8

5 1/2

6

6 1/2

7 1/2

1

3/4

1/2
1 1/2

TABLE III
Minimum spacing between conduit centers thru sidewalls only (inches)
(Double all distances in table for holes located in backwall)
5

4

3 1/2

3

2 1/2

1/2

4 1/2

3 5/8

3 3/8

3

2 5/8

3/4

4 3/4

3 3/4

3 1/2

3 1/8

2 3/4

1

4 7/8

4

3 5/8

3 1/4

3

1 1/4

5 1/8

4 1/8

3 7/8

3 1/2

3 1/8

1 1/2

5 1/2

4 1/4

4

3 5/8

2

5 3/4

4 5/8

4 1/4

3 7/8

2 1/2

6

4 7/8

4 5/8

4 1/4

3 7/8

3

6 1/4

5 3/8

5

4 5/8

3 1/2

6 1/2

5 5/8

5 1/4

4

6 3/4

5 7/8

5

7 1/4

2

1 1/2

1 1/4

2 3/8

2

1 7/8

1 3/4

1 5/8

2 1/2

2 1/8

2

1 7/8

1 3/4

2 5/8

2 3/8

2 1/4

2

2 7/8

2 1/2

2 3/8

3 1/4

3

2 5/8

3 5/8

3 1/4

5A–9

Size

This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application
and conditions under which our products are used are beyond our control, we are not able to guarantee the application and/or
use of same. The user assumes all risks and liability in connection with the application and use of our products.
Note: All dimensions are in inches.
Metric threads available from factory for Group C & D applications only – Consult Factory.
The Adalet engineering department is available to assist in designing custom explosionproof enclosures for your products.
189
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 190

Conduit & Auxiliary Device Drilling and Tapping Guidelines
SPACING FOR AUXILIARY DEVICES INSTALLED
IN BOX WALLS OF CONTROL PANEL ENCLOSURES
USED IN HAZARDOUS LOCATIONS.
When using an Auxiliary Device in the box wall of an enclosure used in hazardous locations,
proper installation requires compliance with the following:
1. A minimum of (5) thread engagement, class 2 fit, required for group C & D applications.
A minimum of (7) thread engagement, class 2 fit, required for group B applications.
2. Table I shows minimum box wall thickness for Auxiliary Device threads.

TABLE I
REQUIRED MINIMUM BOX WALL THICKNESS
Thread Size (In.)
1/2 – 3/4 NPSM
1 NPSM

Group C & D Applications
min. (5) thread engagement

Group B Applications
min. (7) thread engagement

Typical Auxiliary Devices
XBO, XHPB, XHSS, Standard Operators

(14 PITCH)

(11 1/2 PITCH)

3/8 NPSM

(18 PITCH)

3/8 – 16 UNC

3/8 Inch

1/2 Inch

7/16 Inch

5/8 Inch

XCBH Large Handle Assembly

9/32 Inch

13/32 Inch

XCBH Small Handle Assembly

5/16 Inch

7/16 Inch

XMOB, XMOSS, Mini Operators

3. If Auxiliary Device contains undercut in engaging threaded section, the minimum wall thickness shown in Table I must increase
to maintain the minimum required thread engagement. (Fig. A)
4. Table II provides the minimum distance an Auxiliary Device center can be placed from inside corner or back of box.
SEE NOTE 3

TABLE II
AUXILIARY DEVICE THREAD SIZE (In.)

3/8-16
UNC

3/8
NPSM

1/2
NPSM

3/4
NPSM

1
NPSM

Minimum distance from Auxiliary Device
CL to inside corner of back of box.

1-1/2

1-5/8

1-3/4

1-7/8

2

Auxiliary
Device

COUNTERSINK/
CHAMFER DEPTH
WALL Y
THICKNESS

5. Table III shows minimum spacing between conduit and Auxiliary Device entrances.

FIG. A

TABLE III
Minimum space between centers of conduits and auxiliary devices in box wall. (Inches)
Conduit Thread Size (NPT)
5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

3/8

4-1/2

3-5/8

3-3/8

3

2-5/8

2-3/8

2

1-7/8

1-3/4

1-5/8

1-1/2

1/2

4-5/8

3-3/4

3-1/2

3-1/8

2-3/4

2-1/2

2-1/4

2-1/8

2

1-7/8

1-3/4

3/4

4-3/4

4

3-5/8

3-1/4

2-7/8

2-5/8

2-3/8

2-1/4

2-1/8

2

1-7/8

1

5

4-1/4

3-7/8

3-1/2

3

2-3/4

2-1/2

2-3/8

2-1/4

2-1/8

2

5A–10

Aux. Device
Thread Size

TABLE IV

6. Table IV shows minimum spacing
between auxiliary device entrances.
NOTE: Increase distance between
devices as required to maintain
minimum through air spacing of
contacts required by electrical
codes.
7. Double all distances in Table III and
IV for holes located in back wall.

Minimum spacing between Auxiliary Device of
varying thread sizes (Inches)
3/8

1/2

3/4

1

3/8

1-1/2

1-1/2

1-1/2

2-1/2

1/2

1-1/2

2

2

2-1/2

3/4

1-1/2

2

2

3

1

2-1/2

2-1/2

3

3-1/2

Consult factory for layout data sheets.

190
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 191

XCE and XJF Mounting Pans and Hinges

Catalog
Number
(Steel)
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM

0416
0608
0611
0612
0613
0710
0718
0808
0810
0812
0911
1010
1012
1014
1212
1218
1220
1224
1230
1236
1246
1414
1422
1428
1616
1624
1628
1630
1634
1646
1818
1824
1830
1836
2036
2048
2424
2430
2436
3236

HINGES

Catalog
Number
(Aluminum)

Catalog
Number
(Phenolic)

Pan
Dimensions Nominal
Width
Length

XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA

XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB

3
5
5
5
5
6
6

0416
0608
0611
0612
0613
0710
0718
0808
0810
0812
0911
1010
1012
1014
1212
1218
1220
1224
1230
1236
1246
1414
1422
1428
1616
1624
1628
1630
1634
1646
1818
1824
1830
1836
2036
2048
2424
2430
2436
3236

0416
0608
0611
0612
0613
0710
0718
0808
0810
0812
0911
1010
1012
1014
1212
1218
1220
1224
1230
1236
1246
1414
1422
1428
1616
1624
1628
1630
1634
1646
1818
1824
1830
1836
2036
2048
2424
2430
2436
3236

1/4
1/8
1/8
1/8
1/8
1/8
1/8
7
7
6 7/8
8
8 7/8
10 7/8
8 7/8
10 7/8
10 1/2
11
11
10 3/4
10 3/4
10 3/4
12 7/8
12 7/8
12 7/8
14 3/4
14 1/2
26 1/2
14 1/2
32 1/2
14 1/2
16 3/4
16 1/2
16 1/2
16 1/2
34 1/2
46 1/2
22
22
34
29

Enclosure Size
Reference
Inside width x length

15 1/4
7 1/8
10 1/8
11 1/8
12 1/8
9 1/8
17 3/8
7
9 1/8
10 7/8
10
8 7/8
8 7/8
12 7/8
10 7/8
16 1/2
19
23
28 3/4
34 3/4
44 3/4
12 7/8
20 7/8
26 7/8
14 3/4
22 1/2
14 1/2
28 1/2
14 1/2
44 1/2
16 3/4
22 1/2
28 1/2
34 1/2
18 1/2
18 1/2
22
28
22
33

4
6
6
6
6
7
7
8
8
8
9
10
10
10
12
12
12
12
12
12
12
14
14
14
16
16
16
16
16
16
18
18
18
18
20
20
24
24
24
32

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

16
8
11
12
13
10
18
8
10
12
11
10
12
14
12
18
20
24
30
36
46
14
22
28
16
24
28
30
34
46
18
24
30
36
36
48
24
30
36
36

Weight
Each (pounds)
(Steel)

Hinges
Catalog
Number

1 1/2
1
1 1/2
1 3/4
2
1 1/4
2 1/2
1 1/4
1 1/2
2 1/4
2 1/2
2 1/2
3
3 1/2
3 3/4
5 1/2
6 1/2
8
9 3/4
11 3/4
15
5
8
10 3/4
6 3/4
10 1/4
12
12 1/2
14 3/4
20 1/4
8 3/4
11 1/2
14 3/4
18
20
27
15 1/4
19 1/4
23 1/2
28 3/4

XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHC-2
XHC-2
XHC-2
XHC-2
XHC-2
XHD-3

4
6
6
6
6
7
7
8
8
8
9
10
10
10
12
12
12
12
12
12

x 16
x8
x 11
x 12
x 13
x 10
x 18
x8
x10
x 12
x 11
x 10
x 12
x 14
x 12
x 18
x 20
x 24
x 30
x 36

XHD-4
XHC-2
XHF-2
XHF-2
XHD-2
XHF-2
XHF-2
XHF-2
XHD-3
XHF-4
XHF-2
XHF-2
XHF-2
XHF-3
XHF-3
XHF-4
XHF-2
XHF-2
XHF-3
XHF-3

12
14
14
14
16
16
16
16
16
16
18
18
18
18
20
20
24
24
24
32

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Mounting Pans
MATERIAL — Steel: (XSM)
Galvanized 12 gauge steel plate. The catalog number includes the steel
mounting pan complete with 1/4" high spacers and stainless steel
mounting screws.
MATERIAL — Aluminum: (XSA) Consult factory for availability.
MATERIAL — Phenolic: (XSB)
A special phenolic laminated material that has high mechanical and
dielectric strength. It is excellent for mounting and wiring control
equipment. The catalog number includes the phenolic board, 3/8" thick,
complete with 1/4" high spacers and stainless steel mounting screws.

Enclosure Size
Reference
Inside width x length

46
14
22
28
16
24
28
30
34
46
18
24
30
36
36
48
24
30
36
36

5A–11

MOUNTING PANS

Hinge Set
Description:
Made of extruded aluminum alloy consisting
of two sections, female and male (with stainless
steel pin) and four stainless steel hex head bolts.
Designed to allow right or left hand removable or
non-removable installation.
Unless specified, left hand removable hinge
installation will be furnished by factory when
hinged enclosures are ordered.

Note: Catalog numbers represent complete hinge sets
necessary for enclosure assembly.

Note: No installation charge when customer specifies
factory installation of mounting pan.

191
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 192

XCE Glass Windows
DIVISION I AND DIVISION II
CLASS I GROUPS B, C, & D; CLASS II GROUPS E, F, & G
NEMA 7, 9, NEMA 4/IP66 (OPTIONAL)

Circular
Window

Window
Viewing Area Diameter

Overall Window
Cover Diameter

Minimum Enclosure
Inside
Width / Length

XGC 10

1 1/8

3

8

XGC 20

1 15/16

4 1/8

9

XGC 30

3

5 3/16

9

XGC 40

4

6 3/8

9

XGC 52

5 1/4

7 7/8

12

XGC 66

6 11/16

10 3/8

16

XGC 80

8

12 1/8

18

All dimensions are in inches.
Glass window catalog number includes XCE cover machining and installation.
For raintight, watertight NEMA 4/IP66 option add suffix “N4”.
To order glass windows for field installations, add suffix SLF to XGC catalog no.
Consult factory for closer spacing requirements, multiple windows or
combinations of operators and windows.

5A–12

Rectangular
Window

Window
Viewing Area Size

Minimum
Enclosure
Inside Width

Minimum
Enclosure
Inside Length

XGW 0303

3X3

8

8

XGW 0305

3X5

8

10

XGW 0307

3X7

8

12

XGW 0505

5X5

10

10

XGW 0509

5X9

10

14

XGW 0707

7X7

12

12

XGW 0713

7 X 13

12

18

XGW 0909

9X9

14

14

XGW 1111

11 X 11

16

16

XGW 1313

13 X 13

18

18

All dimensions are in inches.
Glass window catalog number includes installation.
For raintight, watertight NEMA 4 option add suffix “N4”.
Consult factory for special viewing area requirement, closer spacing and to
combine windows with other window sizes or operators.

192
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 193

DJF and WJF External Flanged Junction Boxes

DJF DUST-TIGHT EXTERNAL FLANGED JUNCTION BOXES
CLASS II GROUPS E, F, & G; NEMA 9

DJF/WJF
Catalog
Number

Inside Nominal
Dimensions
W
L
D

Mounting
Bolt
Size

Side
Wall
Thickness

Shipping
Weight,
Pounds

061105

6

11

5

8 3/8

13 1/8

6 13/16

7 1/2

8 5/8

3/8

3/8

16

061305

6

13

5

8 1/8

15 1/8

6 13/16

9 1/2

8 5/8

3/8

3/8

18

071805

7

18

5

9 1/8

20 1/8

6 13/16

14 1/2

9 1/8

3/8

3/8

30

121806

12

18

6

14 1/2

20 1/2

7 15/16

14 3/8

14 3/4

1/2

7/16

42

122005

12

20

5

14 1/4

22 1/4

6 15/16

14 3/8

14 3/4

1/2

7/16

47

122406

12

24

6

141/4

26 1/4

7 15/16

18 3/4

14 3/4

1/2

7/16

52

122408

12

24

8

14 1/4

26 1/4

9 15/16

18 3/4

14 3/4

1/2

7/16

62

123006

12

30

6

14 3/8

32 3/8

8 1/16

22 3/4

15

5/8

1/2

67

123208

12

32

8

15

35

10 3/16

27 1/2

14 1/8

1/2

5/8

80

123608

12

36

8

14 3/8

38 3/8

10 3/16

29

14 3/4

1/2

5/8

110

Overall Dimensions
A
B
C

Mounting Lug
CL to CL
E
F

5A–13

WJF WATERTIGHT EXTERNAL FLANGED JUNCTION BOXES
NEMA 4

193
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 194

DJF and WJF External Flanged Junction Boxes

5A–14
194
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 195

XIF/XIFC Explosionproof Internal Flanged Junction Boxes & Control Enclosures
XIF: Junction Boxes
XIFC: Control Enclosures
Optional NEMA 4. Add suffix “N4” to
catalog number.
Use layout sheet for drilling and tapping
specifications.
XIFC Certifications: (N4 Optional)
• Class I, Groups C & D
• Class II, Groups E, F & G
• Class III
• UL 1203 (Classified)

Inside Nominal
Catalog
Number

Mounting Lug

Dimensions

Overall Dimensions

CL to CL

Mounting

Shipping

Bolt

Weight,

W

L

D

A

B

C

E

F

Size

Pounds

4 5/16

3 1/4

5 1/2

5/16

5

XIFC 030303

XIF 030303

3 5/16

3 5/16

3 3/16

4 1/2

4 1/2

XIFC 030603

XIF 030603

3 1/4

5 3/4

3

4 1/2

7 1/16

4 1/4

3 1/4

8

5/16

6 1/2

XIFC 030703

XIF 030703

3 1/4

6 7/8

3

4 1/2

8 1/8

4 5/16

3 5/16

9

5/16

7 1/2

XIFC 030903

XIF 030903

3

4 1/2

10 1/16

4 5/16

3 1/4

11

5/16

9 1/2

XIFC 031103

XIF 031103

3 1/4

10 15/16

3

4 1/2

12

4 5/16

3 1/4

13

5/16

11

XIFC 031303

XIF 031303

3 1/4

12 13/16

3

4 1/2

14 1/16

4 5/16

3 1/4

15

5/16

11 1/2

XIFC 031503

XIF 031503

3 1/4

14 3/4

3 1/16

4 1/2

16

4 5/16

3 1/4

17

5/16

13

XIFC 031803

XIF 031803

3 1/4

17 3/4

3

4 1/2

19

4 1/4

3 1/4

20

5/16

16

XIFC 032403

XIF 032403

3 1/4

23 9/16

3

4 1/2

25 1/16

4 5/16

3 1/4

26

5/16

21

XIFC 033003

XIF 033003

3 1/4

29 1/2

3

4 9/16

31 1/16

4 5/16

3 1/4

32 1/8

5/16

28

XIFC 033603

XIF 033603

3 1/4

35 7/16

3

4 1/2

37

4 3/8

3 1/4

38 1/8

5/16

33

XIFC 040604

XIF 040604

4 1/8

5 7/8

4

5 3/8

7

5 5/16

4 3/8

8 1/4

5/16

8 1/2

XIFC 041204

XIF 041204

4 1/4

11 13/16

4

5 1/2

13 1/8

5 5/16

4 3/8

14 1/4

5/16

15 1/2

XIFC 060606

XIF 060606

5 1/2

5 1/2

6

7

7

7 3/8

5 1/2

8 1/2

3/8

14

XIFC 060608

XIF 060608

5 1/4

5 1/2

8

7

7

9 3/8

5 1/2

8 1/2

3/8

17 1/2

XIFC 061206

XIF 061206

5 1/4

11 1/8

6

7 1/4

13 1/2

7 5/8

5 1/2

15

3/8

28

XIF 061806

6

18

6

7 1/2

19 1/2

7 13/16

5 1/2

21 1/8

3/8

33

XIF 062406

6

24

6

7 1/2

25 1/2

7 3/4

5 1/2

27

3/8

59

XIF 063606

6

36

6

7 1/2

37 1/2

7 13/16

5 1/2

39

3/8

84

XIF 070704

6 7/8

6 7/8

4

5 5/16

6 5/8

9 1/8

3/8

13

XIF 071603

7

16

3 1/2

8 1/2

17 1/2

5 5/16

6 1/2

18 7/8

3/8

36

XIF 083206

8

32

5 7/8

9 1/2

33 1/2

7 7/8

7 1/2

35

3/8

87

XIFC 070704

3 11/32 8 15/16

7 15/16 7 15/16

5B–1

XIF Compliances:
• NEC Class I, Group D
• Class II, Groups E, F & G
• Class III
• UL Standard 886
• CSA Standard C22.2 No. 30
• For XIF consult factory for specific certifications.

Note: All dimensions are in inches and are nominal enclosure size only.
195
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 196

XIF/XIFC Explosionproof Internal Flanged Junction Boxes & Control Enclosures

CAT. # XIF(C)________

5B–2
196
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 197

XIF/XIFC Mounting Pans

MATERIAL — Steel: (XSM)
Galvanized 12 gauge steel plate. The catalog number
includes the steel mounting pan complete with 1/4"
high spacers and stainless steel mounting screws.
MATERIAL — Aluminum: (XSA)
Consult factory for availability.
MATERIAL — Phenolic: (XSB)
A special phenolic laminated material that has high
mechanical and dielectric strength. It is excellent for
mounting and wiring control equipment. The catalog
number includes the phenolic board, 3/8" thick,
complete with 1/4" high spacers and stainless steel
mounting screws.
Note: No installation charge when customer specifies
factory installation of mounting pan.

Catalog
Number
(Aluminum)

Catalog
Number
(Phenolic)

Pan
Dimensions
Width
Length

Enclosure Size
Reference
Inside Width x Length

Weight
Each (pounds)
(Steel)

XSM 0303

XSA 0303

XSB 0303

3

3

3x3

1/4

XSM 0306

XSA 0306

XSB 0306

3

5 1/2

3x6

1/2

XSM 0307

XSA 0307

XSB 0307

3

6 1/2

3x7

1/2

XSM 0309

XSA 0309

XSB 0309

3

8 1/2

3x9

3/4

XSM 0311

XSA 0311

XSB 0311

3

10 1/2

3 x 11

1

XSM 0313

XSA 0313

XSB 0313

3

12 1/2

3 x 13

1 1/4

XSM 0315

XSA 0315

XSB 0315

3

14 1/2

3 x 15

1 1/2

XSM 0318

XSA 0318

XSB 0318

3

17 1/2

3 x 18

1 3/4

XSM 0324

XSA 0324

XSB 0324

3

23 1/2

3 x 24

2 1/4

XSM 0330

XSA 0330

XSB 0330

3

29

3 x 30

2 3/4

XSM 0336

XSA 0336

XSB 0336

3

35

3 x 36

3 1/4

XSM 0406

XSA 0406

XSB 0406

3 7/8

5 1/2

4x6

3/4

XSM 0412

XSA 0412

XSB 0412

3 7/8

11 1/2

4 x 12

1 1/2

XSM 0606

XSA 0606

XSB 0606

51/2

51/2

6x6

1

XSM 0612

XSA 0612

XSB 0612

5 1/2

11 1/2

6 x 12

2

XSM 0618

XSA 0618

XSB 0618

5 5/8

16 7/8

6 x 18

3

XSM 0624

XSA 0624

XSB 0624

5 5/8

22 7/8

6 x 24

4

XSM 0636

XSA 0636

XSB 0636

5 5/8

34 7/8

6 x 36

6

XSM 0707

XSA 0707

XSB 0707

6 1/2

6 1/2

7x7

1 1/2

XSM 0716

XSA 0716

XSB 0716

6 1/2

15 1/2

7 x 16

3

XSM 0832

XSA 0832

XSB 0832

7 1/2

31 1/2

8 x 32

7 1/2

5B–3

Catalog
Number
(Steel)

When ordering separately, be sure to designate that mounting pan is for XIF series
enclosure and specify size of box.

197
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 198

DIF and WIF Junction Boxes

DIF DUST-TIGHT INTERNAL FLANGED JUNCTION BOXES
CLASS II GROUPS E, F, & G; NEMA 9
WIF WATERTIGHT INTERNAL FLANGED JUNCTION BOXES
NEMA 3, 4

5B–4

DIF/WIF
Catalog
Number

Inside Nominal
Dimensions
W
L
D

Mounting
Bolt
Size

Side
Wall
Thickness

Shipping
Weight,
Pounds

101406

10

14

6

10 3/4

14 3/4

7 5/16

12 3/8

10 3/4

3/8

3/8

28

164810

16

48

10

17

49

11 5/8

19

41 1/16

5/8

1/2

150

202408

20

24

8

21

25

9 9/16

22 3/8

17 1/2

1/2

1/2

90

202412

20

24

12

21

25

13 9/16

22 1/2

17 1/2

1/2

1/2

106

243608

24

36

8

25

37

9 5/8

27 1/4

28

5/8

1/2

146

364808

36

48

8

37

49

9 3/8

39 1/4

41

5/8

1/2

242

242414

24

24

14

25

25

15 9/16

26 1/2

17 1/2

1/2

1/2

120

Overall Dimensions
A
B
C

Mounting Lug
CL to CL
E
F

Note: WIF Series includes a one piece neoprene gasket. Mounting lugs optional.
DIF Series does not include mounting lugs or gasket.

198
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 199

XHFA Explosionproof Fire Alarm Stations
CLASS I, GROUPS B*, C, & D;
CLASS II, GROUPS E, F & G, NEMA 4, 7 & 9
Fire alarm call stations, for installation in hazardous atmosphere
locations where emergency control of fire alarm or signal circuits is
required.
Station is painted red for easy identification. Housing and break glass
hammer are cast aluminum alloy. Exposed operator parts are red
anodized aluminum.
A yellow adhesive backed label “Caution-Stand Clear of Area in Front
of Glass to Protect Eyes from Flying Glass”, furnished for application
above the alarm station.

Complete Assembly
Catalog Number
with 3/4” NPT conduit
opening top and bottom

Catalog Number
with 1” NPT conduit
opening top and bottom

XHFA 31-N4

XHFA 41-N4

XHFA 32-N4
XHFA 33-N4

XHFA 42-N4
XHFA 43-N4

Replacement glass: Catalog number XHFG

* Add GB suffix to part number for group B.
Example: XHFA 31-GB-N4.

5C–1

Important Notice:
Contacts are shown as held in their actuated position.

Note: Contact blocks furnished as standard.
Compliances:

Maximum current ratings for control circuit contacts

NEC Class I, Group B*, C and D
Class II, Groups E, F & G
UL Standard 886 • UL Standard 689
UL Standard UL38 manually actuated signaling
boxes for use with Fire Protective Signaling Systems.
Aluminum Alloy Copper Content 0.3% max.

Volts

Make
Amperes

Break
Amperes

Continuous
Carrying

120
240

60
30

6
3

10
10

199
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 200

Junction Boxes General Purpose, Weatherproof

NEMA TYPE 1, NEMA TYPE 4 (OPTIONAL)
JP (UNFLANGED TYPE FOR SURFACE MOUNTING)
JF (FLANGED TYPE FOR SURFACE MOUNTING)
JR (RECESSED COVER TYPE FOR FLUSH MOUNTING)
JH (HINGED COVER TYPE FOR SURFACE MOUNTING)
JU (ABOVE GROUND TYPE FOR CONDUIT MOUNTING)
APPLICATIONS:
Designed for installation in electrical systems requiring rugged applications.
• Wiring: pull boxes, splices, taps and terminal strips.
• Housing for apparatus, instruments, terminal strips and other equipment.
FEATURES:
• Rugged sand-cast copper-free aluminum alloy, 0.3% maximum copper content.
• Tumblasted for quality appearance.
• Boxes are furnished complete with cover, neoprene gasket and stainless steel
cover bolts, except “JU Series” enclosures, which are furnished with steel zinc
dichromate plated cover bolts.
• Grounding screw standard.
OPTIONS:
• Cast-on mounting buttons, bosses and pads available for terminal block or
equipment mounting.
• Conduit openings available, drilled and tapped or drilled slip fit for type 1
applications, to customer requirements.
• NEMA type 4, standard on JR Series when used for direct burial in concrete or
cinder fill, JF, JP and JH require addition of mounting lugs, cast on long side
unless otherwise specified. Wall thickness must be 5/16” or greater for conduit
sizes up to 2” NPT to permit, not less than 3-1/2 threads of engagement.
Enclosures with less than 5/16” wall thickness require padded conduit entrances
to maintain 3-1/2 thread engagement.

5D–1
Compliances
CSA STANDARD C22.2 NO. 18
UL STANDARD 50
CONTACT

FACTORY FOR SPECIFIC

UL, CSA,

FILE NUMBERS

200
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 201

Junction Boxes General Purpose, Weatherproof

W

Nominal Inside
Dimensions (Inches)
L

D

Wall
Thick.
Inches

Ship.
Wt.
Lbs.

Catalog
Number

W

Nominal Inside
Dimensions (Inches)
L

D

Wall
Thick.
Inches

Ship.
Wt.
Lbs.

2-3/4

4-1/4

1-3/16

1/8

1

JP 121204

12

12

JP 030302

3-1/2

3-1/2

2-1/8

1/8

1

JP 121206

12

12

4

5/16

17

6

5/16

JP 030303

3-9/16

3-9/16

2-7/16

5/16

2

JP 121208

12

21

12

8

5/16

JP 040403

4

4

2-1/2

5/32

1-1/2

JP 121604

24

12

16

4

5/16

JP 040404

4

4

4

1/4

3

17

JP 121606

12

16

6

5/16

JP 040603

4

6

2-1/2

1/4

21

3

JP 121608

12

16

8

5/16

JP 040604

4

6

4

26

7/32

4

JP 121806

12

18

6

5/16

JP 040804

4

8

26

4

5/16

6

JP 121810

12

18

10

5/16

JP 041204

4

36

12

4

5/16

8

JP 122406

12

24

6

5/16

38

JP 060603
JP 060604

6

6

3-1/2

5/16

6

JP 122408

12

24

8

5/16

48

6

6

4

5/16

6

JP 123606

12-1/8

36-1/2

6

1/2

82

JP 060606

6

6

6

5/16

7

JP 141406

14

14

6

5/16

25

JP 060804

6

8

4

5/16

7

JP 151508

15

15

8

3/8

32

JP 060806

6

8

6

5/16

10

JP 181806

18

18

6

5/16

57

JP 061004

6

10

4

5/16

9

JP 181808

18

18

8

5/16

48

JP 061204

6

12

4

5/16

10

JP 181810

18

18

10

5/16

53

JP 061206

6

12

6

5/16

11

JP 181812

18

18

12

5/16

63

JP 080804

8

8

4

5/16

9

JP 182408

18

24

8

3/8

65

JP 080806

8

8

6

5/16

11

JP 183606

18

36

6

1/2

94

JP 080808

8

8

8

5/16

12

JP 183608

18

36

8

1/2

126

JP 081004

8

10

4

5/16

9

JP 242408

24

24

8

3/8

80

JP 081006

8

10

6

5/16

13

JP 242410

24

24

10

5/16

92

JP 081008

8

10

8

5/16

15

JP 243008

23-3/4

23-3/4

8

3/8

94

JP 081204

8

12

4

5/16

11

JP 243606

24

36

6

1/2

114

JP 081206

8

12

6

5/16

16

JP 243608

24-1/8

36-1/8

8

3/8

113

JP 101204

10

12

4

5/16

12

JP 243612

24

36

12

1/2

173

JP 101206

10

12

6

5/16

18

JP 363612

36

36

12

1/2

226

JP 101208

10

12

8

5/16

21

Catalog
Number
JP 020401

5D–2

UNFLANGED TYPE FOR SURFACE MOUNTING

CSA Certified LR28852
UL Listed E33075

201
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 202

Junction Boxes General Purpose, Weatherproof
FLANGED TYPE FOR SURFACE MOUNTING

W

Nominal Inside
Dimensions (Inches)
L

6

6

JF 060606

6

6

JF 060804

6

8

JF 060806

6

8

6

1/4

9

JF 061206

6

11-13/16

6

1/4

11

Catalog
Number
JF 060604

D

Wall
Thick.
Inches

Ship.
Wt.
Lbs.

4

1/4

5-1/2

6

1/4

8

4

7/32

6

JF 080804

8

8

4

3/8

11

JF 080806

8

8

6

3/8

13-1/2

JF 081206

8

12

6

5/16

14-1/2

JF 121206

12

12

6

1/4

17

JF 121208

12

12

8

1/4

20

JF 121810

12

18

10

5/16

47

JF 122406

12

24

6

3/8

35

JF 122408

12

24

8

7/16

62

JF 183608

18

36

8

1/2

157

CSA Certified LR28852
UL Listed E33075

RECESSED COVER TYPE FOR FLUSH MOUNTING

W

Nominal Inside
Dimensions (Inches)
L

5D–3

D

Wall
Thick.
Inches

Ship.
Wt.
Lbs.

4

4

JR 040604

4

6

4

1/4

5

4

1/4

JR 060604

6

6

6

4

1/4

5-1/2

JR 060606
JR 060804

6

6

6

1/4

8

6

8

4

1/4

6

JR 060806

6

8

6

1/4

9

JR 061006

6

10

6

1/4

12

JR 061206

6

12

6

1/4

14

JR 080804

8

8

4

3/8

12

JR 080806

8

8

6

3/8

14

JR 080808

8

8

8

3/8

18

JR 081206

8

12

6

5/16

15

JR 101006

10

10

6

1/4

18

JR 121206

12

12

6

1/4

19

JR 121208

12

12

7-15/16

1/4

20

JR 121810

12

18

10

5/16

48

Catalog
Number
JR 040404

JR 122406

12

24

6

3/8

36

CSA Certified LR28852

JR 161606

16-1/4

16-1/4

6

5/16

34

UL Listed E33075

JR 161808

16

18

8

3/8

44
50

JR 161810

16

18

10

3/8

JR 181812

18-3/16

18-3/16

12-5/32

5/16

66

JR 183608

18

36

8

1/2

150

All JR style weatherproof cast aluminum junction boxes are
coated with a black asphalt paint - for direct burial in concrete or
cinder fill and are UL approved for this application. Covers are
plain with no coating. Covers have rubber stamped marking
“Suitable for use in concrete or cinder fill”.

202
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 203

Junction Boxes General Purpose, Weatherproof

HINGED COVER TYPE FOR SURFACE MOUNTING

Catalog
Number

W

Nominal Inside
Dimensions (Inches)
L

D

Wall
Thick.
Inches

Ship.
Wt.
Lbs.
6

With 2 Hinges and 1 Wing Bolt
JH 060604

6

6

4

1/4

JH 060606

6

6

6

1/4

8

JH 060804

5-15/16

8

4

1/4

8

5-15/16

8

6

1/4

9

JH 060806

With 2 Hinges and 2 Wing Bolts
JH 061004

5-15/16

10

4

1/4

10

JH 061204

5-15/16

11-7/8

3-15/16

1/4

10-1/2

JH 061206

5-15/16

11-7/8

6

1/4

13-1/2

JH 080804

8

8

4

1/4

9-1/2

JH 080806

8

8

6

1/4

11-1/2

JH 080808

8

8

8

1/4

13

JH 081004

8

10

4

1/4

11

JH 081006

8

10

6

1/4

12

JH 081008

8

10

8

1/4

14

JH 081204

8

12

4

1/4

12

JH 081206

8

12

6

1/4

14-1/2

CSA Certified LR28852
UL Listed E33075

With 2 Hinges and 4 Wing Bolts

Catalog
Number

W

Nominal Inside
Dimensions (Inches)
L

D

Wall
Thick.
Inches

Ship.
Wt.
Lbs.

JH 101204

10

12

4

1/4

15

JH 101206

10

12

6

1/4

17

JH 121604

12

16

4

1/4

21

JH 101208

10

12

8

1/4

19

JH 121606

12

16

6

1/4

23

JH 121204

12

12

4

1/4

17-1/2

JH 121608

12

16

8

1/4

29

JH 121206

12

12

6

1/4

21-1/2

JH 141406

14-1/8

14-1/8

6-1/6

1/4

21

JH 121208

12

12

8

1/4

24-1/2

JH 151508

15

15

8

1/4

40

With 2 Hinges and 4 Wing Bolts

With 3 Hinges and 5 Wing Bolts
JH 121806

12

18

6

1/4

26-1/2

JH 121810

12

18

10

1/4

46-1/2

JH 122406

12

24

6

5/16

37

JH 122408

12

24

8

5/16

47

JH 123606

12-1/8

36-1/2

6-1/16

1/2

78

18

18

6

5/16

52

JH 181808

18

18

8

5/16

50

JH 181810

18

18

10

5/16

54

JH 181812

18

18

12

5/16

75

JH 182408

18

24

8

3/8

89

JH 183606

18

36

6-1/16

1/2

103
138

JH 183608

18

36

8

1/2

JH 242408

24

24

8

3/8

77

JH 243008

24

30

8

3/8

116

JH243606

24

36

6-1/16

1/2

128

JH 243608

24

36

8

1/2

136

JH 243612

24

36

12

1/2

165

203
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

5D–4

With 3 Hinges and 7 Wing Bolts
JH 181806

15599 Sec.5 E 12/9/01 11:06 AM Page 204

Junction Boxes Explosionproof

JUNCTION BOXES
THREADED FLAT COVER STYLE
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 3, 7 & 9,
Raintight Junction Boxes for Service Station Islands
XSO 885 is a larger cast aluminum raintight explosionproof
box having inside dimensions of 8” x 8” x 5” deep.
Standard blank, drilled and tapped to specification. Any of
the XVS “sealing” hubs can be installed in the back.

Catalog
Number

Nominal Inside
Dimensions (In.)

Shipping
Weight Lbs.

XSO 885

8 x 8 x 5 deep

20

91⁄8"

91⁄8"

XVS VERTICAL SEALING HUBS

7

69⁄16"

Vertical sealing hubs save space and are accessible from
the inside of the box for packing and sealing. Size, number
and location of seals must be specified in the order. They
must be factory installed and must be added to the price
of the box. Catalog number and price include installation in
the box. The male thread is not a standard pipe thread.
UL & CSA approval of XSO 884 & XSO 885 is maintained
with use of XVS hub.

5E–1

Catalog
Number

Conduit
Size

A

B

Dimensions (Inches)
C
D

XVS4

1”

2-1/16

1-3/4

XVS5

1-1/4”

2-1/2

2-1/8

2

1-1/4

11/16

XVS6

1-1/2”

2-3/4

2-3/8

2-1/4

1-9/16

11/16

XVS8

2”

3-3/16

2-7/8

2-3/4

2

11/16

1-5/8

7/8

E
11/16

NOTE: Sealing hubs for use only with Adalet XSC sealing compound.

CSA Certified LR27991
UL Listed E10493
204
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:06 AM Page 205

Junction Boxes Explosionproof

JUNCTION BOXES
THREADED FLAT COVER STYLE
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 3, 7 & 9,
Raintight Junction Boxes for Service Station Islands
These three sizes of flush mounting service station
island junction boxes should answer all
requirements for station island loads. The side walls
are cast blank and are drilled and tapped to
requirements. The wall sections are heavy enough
for 2” conduit. They are all made raintight by Buna-N
O-ring seals, having excellent resistance to
petroleum oils and aromatic hydrocarbons.
XSO 663B, box, having inside dimensions of
6” x 6” x 3” deep has 2-1” “sealing” hubs cast
integrally in the back of the box, one plugged. The
side walls are drilled and tapped to specification.

5 3⁄8"

XSO 663S is the same box as XSO 663B but is a
stock box drilled and tapped for three 3/4” conduits
on each of two opposite sides, also has the 2-1”
sealing conduit hubs, one plugged.
XSO 884, a larger 8” x 8” x 4” deep cast aluminum
raintight explosionproof box is completely flexible in
that any size and number of sealing hubs, type XVS
shown on page 5E–1, can be installed in the back,
and conduit holes can be drilled and tapped in any
or all side walls from 1/2” through 2”. Stocked
blank, drilled and tapped to layout.

5E–2

XSO 884S is the same box as XSO 884 but is
stocked, drilled and tapped, to handle most island
requirements, consisting of one 1-1/4” “sealing
conduit hub” in the back, and with three 3/4”
drilled and tapped conduit holes on each of two
opposite sides.

Number & Size of Conduit
Catalog
Number

Nominal Inside
Dimension (In.)

Each
Side

XSO 663S

6 x 6 x 3 deep

None

XSO 663B

6 x 6 x 3 deep

XSO 884

8 x 8 x 4 deep

XSO 884S

8 x 8 x 4 deep

Top

Bottom

Back
Sealing

3-3/4”

3-3/4”

2-1”

Shipping
Wt. Lbs.

D & T to specifications thru 2”
D & T to specifications thru 2”
None

3-3/4”

3-3/4”

8
8-1/4
18

1-11/4”

18

NOTE: Sealing hubs for use only with Adalet XSC sealing compound.
CSA Certified LR27991
UL Listed E10493
205
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:06 AM Page 206

Explosionproof and Dust-Tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUP D;
CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9
MULTI-HUB GENERAL PURPOSE BOXES
X82C/X83C

Designed for general wiring in hazardous locations. For pulling and
splicing conductors. X82 box has six 1/2” conduit entrances in the
sides and two 3/4” conduit entrances in the back.
X83 box has six 3/4” conduit entrances in the sides and two 3/4”
conduit entrances in back. Boxes are furnished with close-up plugs as
shown in chart.

X82/X83

Catalog

Conduit

Left/Right

Number

Size

Sides

Top

Number of Hubs
Bottom

Back

Qty

Wt. Lbs.

X82*

1/2”

One 1/2”

Two 1/2”

Two 1/2”

Two 3/4”

10

19

And

Plugged

Open

One

Both

Plugged

Plugged
10

19

10

24

3/4”
X83*

X643C

X643*

3/4”

One 3/4”

Two 3/4”

Two 3/4”

Two 3/4”

Plugged

Open

One

Both

Plugged

Plugged

3/4”

One 3/4”

One 3/4”

Two 1”

And

Open

Open,

Open

1”

Std. Package

One Boss

One Boss

Undrilled

Undrilled

COVERS ONLY (CONSULT FACTORY FOR APPROVALS)
X643
Catalog

Standard Package

Number

Quantity

Weight Lbs.
4

X82C

Blank

10

X83C

Blank

10

4

X643C

Blank

10

4

Dome

1

1

XDC

5E–3

X8230

O-Ring for NEMA 4 watertight

To order box with Dome Cover add XDC as suffix to catalog number required.

XDC

*
*

CSA Certified LR27991
UL Listed E10493

Compliance
NEC Class I, Group D Class II, Groups E, F, G - Class III
UL Standard 886 - CSA Standard C22.2 No. 30

206
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:06 AM Page 207

Explosionproof and Dust-Tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUP D;
CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9
MULTI-HUB GENERAL PURPOSE BOXES
Designed for general wiring in hazardous locations. For pulling and
splicing conductors, also serves as fixture mounting outlets with
appropriate cover.
Boxes have 4 conduit entrances and are furnished with 2 close-up plugs.

Catalog
Number

Conduit
Size (In.)

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJBCC2*

1/2

XJBCC3*

3/4

Blank

10

26

Cover

10

26

XJFCC2

1/2

XJFCC3

3/4

1/2” Stem

10

26

Cover

10

26

XJFC3C2
XJFC3C3

1/2

3/4” Stem

10

26

3/4

Cover

10

26

COVERS ONLY
XJBC

Blank

10

4

XJFC2

1/2” Stem

10

4

XJFC3

3/4” Stem

10

4

Nominal Dimensions (Inch)
A

XJBC & XJFC
B

1/2

2-1/2

1-13/16

3/4

2-1/2

1-13/16

5E–4

Conduit
Size

Mounting hole size 5/16”

*
*

CSA Certified LR27991
UL Listed E10493

Compliance
NEC Class I, Group D Class II, Groups E, F, G - Class III
UL Standard 886 - CSA Standard C22.2 No. 30

207
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:06 AM Page 208

Explosionproof and Dust-Tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUP C AND D;
CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9
THERMOCOUPLE HEAD BOX

XJAY Junction Box for thermocouple sensing heads. Body has 1/2”
NPT entrance for probe unit and one 3/4” NPT conduit entrance with
conduit stop. The body has an exterior pad 5/8” wide across the back
between the conduit hubs. The interior of the box can be blind tapped
into the back pad with screw spacing up to 2-3/4” for mounting
terminal strips or connection blocks. The outside boss on the 1/2”
hub and the interior boss on the cover can be blind tapped for screws
for use with a retaining chain at additional cost. Consult factory.

XJAY

Catalog
Number

Conduit
Size

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJAY

1/2”-3/4” (1) EA.

10

10

XJAO

O-Ring for NEMA 4 watertight

XJAYRC

Cover retaining chain

5E–5
Compliance
NEC Class I, Groups C, D
Class II, Groups E, F, G - Class III
UL Standard 886 - CSA Standard
C22.2 No. 30

208
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:07 AM Page 209

Explosionproof and Dust-Tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUP D;
CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9
MULTI-HUB GENERAL PURPOSE BOXES
Designed for general wiring in hazardous locations.
For pulling and splicing conductors.

XJLB

Number of Hubs

Std. Package

Catalog

Conduit

Number

Size

Each Side

Top

Bottom

Back

Qty

Wt. Lbs.

XJLB2*

1/2”

None

None

1-1/2”

1-1/2”

10

10

XJLB3

3/4”

None

None

1-3/4”

1-3/4”

10

10

XJTB2*

1/2”

1 - 1/2”

None

1-1/2”

1-1/2”

10

9

COVERS ONLY (CONSULT FACTORY FOR APPROVALS)
XJU23

Blank Cover

10

3

XJUDC

Dome Cover

10

8

To order box with Dome Cover add XJUDC as suffix to catalog number required.

*
*

CSA Certified LR27991
UL Listed E10493

5E–6

XJTB

XJUDC

209
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:07 AM Page 210

Explosionproof and Dust-Tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUP D;
CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9
MULTI-HUB GENERAL PURPOSE BOXES
Designed for general wiring in hazardous locations. For pulling and
splicing conductors, these boxes also serve as fixture mounting
outlets with appropriate cover.
Boxes have 4 conduit entrances and furnished with 2 close-up plugs.
XJULB has 5 conduit entrances and furnished with 3 plugs.
Box Mounting hole size 5/16”.

Nominal Dimensions (Inch)

XJULB

XJUC

Catalog
Number

Conduit
Size

Cover
Style

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJUC2*

1/2

Blank

10

11-1/2

XJUC3*

3/4

Blank

10

11-1/2

XJULB2

1/2

Blank

10

11-1/2

XJULB3

3/4

Blank

10

11-1/2

COVERS ONLY (CONSULT FACTORY FOR APPROVAL)
XJU23

Blank Cover

10

3

XJUDC

Dome Cover

10

8

To order box with Dome Cover add XJUDC as suffix to catalog number required.

*
*

XJUDC

CSA Certified LR27991
UL Listed E10493

5E–7
210
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 E 12/9/01 11:07 AM Page 211

Explosionproof and Dust-Tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT CONTROL STATIONS
FOR PANEL MOUNTING
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9
This group of station boxes and devices is designed for mounting on
panel boards so that pilot lights, pushbuttons and switch handles are
flush with panel fronts and the bodies or housings are in back of the
panel. Threaded necks are provided with locknuts to clamp fittings in
place on panels. The parts extending beyond the face of the panel have
a black anodized finish.

XB1

XB2

Station boxes are available in two styles. Economical style XA single
station is suitable for 600 volt maximum use. XA bodies have threaded
covers and are provided with 4 tapped hubs and 3 plugs. Style XB is
suitable for combinations of pilot lights, pushbuttons and selector
switches for 600 volt maximum use and are large enough to include pilot
light transformers. XB bodies have flat machined joint covers fastened
with machine screws. Covers give maximum accessibility to interiors.
Catalog
Number

Description

XA 2

1 station with four 1/2" tapped
openings, three plugs

XB3

XB4

W

Outside Dim.
L
D

3 3/8 O.D.

–

2 5/16

–

2 5/16

Weight Ea.
Pounds

1

XA 3

1 station with four 3/4" tapped
openings, three plugs

3 3/8 O.D.

XB 1

1 station box – specify hubs

3 1/2

4 7/16 3 7/16

XB 2

2 station box – specify hubs

3 1/2

6 3/8

XB 3

3 station box – specify hubs

3 1/2

8 1/16 3 7/16

2 3/4

XB4

4 station box – specify hubs

3 1/2

9 5/8

3 1/4

1
1 3/4

3 7/16

3 7/16

2

Compliances: NEC Class I, Groups C & D (XA Series - Group D)
Class II, Groups E, F, G
All station boxes are drilled and tapped with 3/4" NPSM thread for
operator, or pilot lights. Unused openings must be plugged with XPP
plugs. XB style boxes are suitably padded for two conduit openings on
one end and one on opposite end. 1" maximum conduit size. Box price
includes one or two conduit openings; specify size, location and number
of holes. Holes in panels should be 1-1/8" diameter with 1-3/4" centers
for XB box.

211
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

5E–8

XA

15599 Sec.5 E 12/9/01 11:07 AM Page 212

Fittings and Accessories
FSO & FDO OUTLET BOXES
DRILLED & TAPPED TO ORDER
Cast aluminum alloy (copper content 0.3% max)

FSO can be tapped with 1” conduit maximum and FDO
can be tapped with 1-1/2” conduit maximum. Two 3/4”
maximum conduit holes in top and one hole in bottom.
NOTE: Box can be rotated 180° to meet your needs.

Catalog
Number

Outside Nominal Dimension
W
L
D

Description

Standard
Package

Standard Pkg.
Weight Lbs.

FSO

3

4-3/4

1-3/4

Box, shallow type

20

20

FDO

3

4-3/4

2-3/4

Box, deep type

20

31

WSO

3

4-3/4

—

Cover, weatherproof

10

2

(Furnished with screws & gasket)
WSG
FS21

Gasket, Neocork 1/2” conduit
3-1/16

5-1/2

1-3/4

5E–9

Box, shallow type, hub

20

15

FSH2

1/2” Female to 3/4” Male

50

4

FSH3

3/4” Female to 3/4” Male

50

3

FSP2

1/2” Conduit plug

100

2

FSP3

3/4” Conduit plug

100

3

212
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:10 AM Page 213

Explosionproof Enclosures With Threaded Cover

Solid Threaded Cover

Threaded Dome Cover

Threaded Glass Cover

Applications:
• Adalet Junction Boxes and Instrument Housings are designed for installation in
electrical conduit systems for hazardous environments.
• Wiring: Pull boxes, splices, taps and terminal strips.
• Housing for apparatus, instruments and other equipment.

Features
• Rugged sand-cast aluminum copper-free alloy — 0.3% max. copper content.
• Tumblasted for quality appearance.
• Cast-on mounting lugs, ease of field installation.
• Grounding screw standard.

Options
• NEMA 3, 4 available; Features installation of an O-ring gasket on cover.
• Conduit openings available, drilled and tapped to customer requirements.
• Cast-on mounting buttons, bosses and pads available.

6A–1

Notes:
Where reference is made to Class I and Class II hazardous locations, the
equipment is suitable for use in both Division 1 and Division 2 hazardous
locations.

213
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 214

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJD

XJX

XJHC

XJDA

XJS
(Can be tapped on
side pads only)

XJM

XJMA

XJHB

XJK

XJL

XJT

XJMC

XJHA

XJKA

XJN

Certifications

XJWH

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

XJWT

6A–2
214
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 215

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJDGC
XJDFGC*

XJMCGC*

XJTGC
XJTFGC*

XJMGC*

XJMAGC*

XJXGC

XJLGC

* includes internal flange and meter mounting plate.

XJNGC 6 & 12

XJHAGC

XJHBGC

XJHCGC

XJKGC

XJKAGC

Certifications

XJWHGC

XJWTGC

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

Back wall mounting plates optional
on some housings. Consult factory.

**XJOGC Enclosure is UL Classified and
CSA Certified

215
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

6A–3

**XJOGC

15599 Sec.6 12/9/01 11:11 AM Page 216

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJDH

XJXH

XJHCH

XJDAH

XJSH
(Can be tapped on
side pads only)

XJMH

XJMAH

XJHBH

XJKH

XJLH

XJMCH

XJKAH

XJTH

XJHAH

XJNH 6 & 12

Certifications

XJWHH

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

XJWTH

6A–4
216
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 217

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJDGCH
XJDFGCH*

XJMCGCH*

XJTGCH
XJTFGCH*

XJMGCH*

XJMAGCH*

XJXGCH

XJLGCH

* includes internal flange and meter mounting plate.

XJNGCH 6 & 12

XJHAGCH

XJHBGCH

XJHCGCH

XJKGCH

XJKAGCH

Certifications

XJWTGCH

Back wall mounting plates optional
on some housings. Consult factory.

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

6A–5

XJWHGCH

217
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 218

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional)

XJDX

XJXX

XJHCX

XJDAX

XJSX
(Can be tapped on
side pads only)

XJMX

XJMAX

XJHBX

XJKX

Certifications

XJWHX

XJWTX

XJLX

XJMCX

XJKAX

XJTX

XJHAX

XJNX 6 & 12

6A–6

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No.
30 by UL
• CENELEC EN 50.014 & 50.018 EExd
IIB+H2 IP60, (optional IP66 with o-ring
seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
with o-ring seal)
• Demko Certified 99E. 124129U
• UL Classified, Class I, Zone 1, Group IIB
Drilled and tapped to specification,
attach layout sheet.

218
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 219

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional)

XJDGCX
XJDFGCX*

XJMCGCX*

XJTGCX
XJTFGCX*

XJMGCX*

XJMAGCX*

XJXGCX

XJLGCX

* includes internal flange and meter mounting plate.

XJNGCX 6 & 12

XJHAGCX

XJHBGCX

XJHCGCX

XJKGCX

XJKAGCX

Certifications

XJWTGCX

Back wall mounting plates optional
on some housings. Consult factory.

6A–7

XJWHGCX

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No.
30 by UL
• CENELEC EN 50.014 & 50.018 EExd
IIB+H2 IP60, (optional IP66 with o-ring
seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
with o-ring seal)
• Demko Certified 99E. 124129U
• UL Classified, Class I, Zone 1
Drilled and tapped to specification,
attach layout sheet.
219

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 220

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional)

XJDHX

XJXHX

XJHCHX

XJDAHX

XJSHX
(Can be tapped on
side pads only)

XJMHX

XJMAHX

XJHBHX

XJKHX

Certifications

XJWHHX

XJWTHX

XJLHX

XJMCHX

XJKAHX

XJTHX

XJHAHX

XJNHX 6 & 12

6A–8

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G
• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No.
30 by UL
• CENELEC EN 50.014 & 50.018 EExd IIB
+ H2 IP60, (optional IP66 with o-ring
seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
with o-ring seal)
• Demko Certified 99E.124129U
• UL Classified, Class I, Zone 1, Group IIB
+ H2
Drilled and tapped to specification,
attach layout sheet.

220
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 221

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60; IP66 (optional); Exd IIB + H2 IP66 (optional)

XJDGCHX
XJDFGCHX*

XJMCGCHX*

XJTGCHX
XJTFGCHX*

XJMGCHX*

XJMAGCHX*

XJXGCHX

XJLGCHX

* includes internal flange and meter mounting plate.

XJNGCHX 6 & 12

XJHAGCHX

XJHBGCHX

XJHCGCHX

XJKGCHX

XJKAGCHX

Certifications

XJWTGCHX

Back wall mounting plates optional
on some housings. Consult factory.

• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No. 30
by UL
• CENELEC EN 50.014 & 50.018 EExd IIB +
H2 IP60, (optional IP66 with o-ring seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
w/o-ring seal)
• Demko Certified 99E.124129U
• UL Classified, Class I, Zone 1, Group IIB + H2
Drilled and tapped to specification,
attach layout sheet.

221
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

6A–9

XJWHGCHX

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G

15599 Sec.6 12/9/01 11:11 AM Page 222

Explosionproof Meter Instrument Housings
METER AND INSTRUMENT HOUSINGS
SQUARE WINDOW THREADED STYLE
CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 7 & NEMA 9
Designed for 3 1/2" Rectangular Meters

Non Magnetic Copper-free aluminum casting
designed for specific instruments and meters
Features
Recessed window with no exposed hardware or protrusions on the
cover. Provides clean finished appearance compatible with
rectangular meters. Designed for 3 1/2" rectangular and 4 1/2"
round meters. Furnished with cast inside mounting ears to support
adapter plate for meter mounting. Interior neck opening has
clearance for meter face, diagonal dimension 3 13/16" x 3 1/4".

Mounting
Can be surface mounted or panel mounted in panels up to 1/4"
thick. Panel mounting requires 5 5/8" round opening allowing neck
to protrude through the panel and the cover only appears on the
front surface of the panel. Cover locks in position with set screw.
For additional support, the front surface under the cover of the box
can be drilled and tapped with blind holes on 5 1/2" x 5 1/2" centers
for screw attachment. Requires countersunk screw openings in
panel.

XJSWGC

For specific meter application consult factory.
(Meter not included)

6A–10

Certifications
• UL Classified E81696
• CSA Certified LR27991

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203
• CSA Standard C22.2 No. 30
Drilled and tapped to specification,
attach layout sheet.

222
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 223

Explosionproof Enclosures With Threaded Cover
JUNCTION BOXES THREADED DOME COVER STYLE
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUP C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJLD

XJTD

XJHAD
Without Cover
To show Mounting Plate
(Optional)

XJHCD

XJWT

XJKD

XJW

XJKAD

XJWH

XJHAD

XJSD

XJW Modified
To house transfer switch
Modification
(Not UL or CSA)

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

Compliance
• NEC Class I, Division I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 886
• CSA Standard C22.2 No. 30
Drilled and tapped to specification,
attach layout sheet.
223

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

6A–11

Certifications
• UL Listed E10493
• CSA Certified LR27991

15599 Sec.6 12/9/01 11:11 AM Page 224

Explosionproof Enclosures With Threaded Cover

XJD

XJK

XJMGC

XJKD

(D is to glass retaining ring)

(D is to underside of cover)
Base

Inside Nominal

Overall

Mounting

Cover

Window

Catalog

Dimensions

Dimensions

CL to C L

Opening

Viewing
Dia.

Dia.

Number

W

L

XJD

4 1/8

XJDGC

4 1/8

XJDFGC**
XJDA

D

A

B

4 1/8

3 7/8

5 5/16

4 1/8

4 1/16

5 5/16

4 1/8

4 1/8

4 1/16

5 3/4

5 3/4

Flange

Max.

Opening Conduit

Mount.

Ship.

Bolt

Wt.

Size

Size

Pounds
5 3/4

C

E

F

Dia.

5 5/16

4 7/8

6 3/16

3 3/4

3 3/4

-

-

2

3/8

5 5/16

5 9/16

6 3/16

3 3/4

3 3/4

3

-

2

3/8

5

5 5/16

5 5/16

5 9/16

6 3/16

3 3/4

2 7/8

3

2 3/4

2

3/8

6
12

5 7/8

7 1/16

7 1/16

7 1/4

8 3/8

5 1/4

4 3/16

-

-

2

3/8

XJS

4 DIA.

3 3/8

4 7/8

4 7/8

4 1/2

3 3/4

3 3/4

4

-

-

1

1/4

3

XJSD

4 DIA.

4 7/16

4 7/8

4 7/8

5 1/2

3 3/4

3 3/4

4

-

-

1

1/4

3 1/2

XJL

6

6

4 7/8

7

7

6 1/8

8 3/8

5 1/4

5 3/8

-

-

2

3/8

11

XJLD4

6

6

8 9/16

7

7

9 7/8

8 3/8

5 1/4

5 3/8

-

-

2

3/8

12

XJLD6

6

6

10 1/6

7

7

11 7/16

8 3/8

5 1/4

5 3/8

-

-

2

3/8

12 1/4

XJLD10

6

6

14 9/16

7

7

15 15/16

8 3/8

5 1/4

5 3/8

-

-

2

3/8

14

XJLD13

6

6

17 9/16

7

7

18 15/16

8 3/8

5 1/4

5 3/8

-

-

2

3/8

15

XJLGC

6

6

3 7/8

7

7

6 3/16

8 3/8

5 1/4

5 3/8

4

-

2

3/8

11

XJT

5 13/16

6 9/16

5 7/16

6 13/16

7 9/16

6 5/8

7 3/4

6

5 3/8

-

-

2

7/16

12 3/4

XJTD4

5 13/16

6 9/16

9 1/16

6 13/16

7 9/16

10 3/8

7 3/4

6

5 3/8

-

-

2

7/16

13 1/2

XJTD6

5 13/16

6 9/16

10 9/16

6 13/16

7 9/16

11 15/16

7 3/4

6

5 3/8

-

-

2

7/16

14

XJTD10

5 13/16

6 9/16

15 1/16

6 13/16

7 9/16

16 7/16

7 3/4

6

5 3/8

-

-

2

7/16

15 1/2

XJTD13

5 13/16

6 9/16

18 1/16

6 13/16

7 9/16

19 7/16

7 3/4

6

5 3/8

-

-

2

7/16

16 1/2

XJTGC

5 13/16

6 9/16

4 5/16

6 13/16

7 9/16

6 5/8

7 3/4

6

5 3/8

4

-

2

7/16

12 3/4

XJTFGC**

5 13/16

6 9/16

4 5/16

6 13/16

7 9/16

6 5/8

7 3/4

6

5 3/8

4

4 1/8

2

7/16

13

XJX

4 3/4

4 3/4

4 3/16

5 3/4

5 3/4

5 1/2

6 3/4

4 3/4

4 5/8

-

-

2

1/4

7

XJXGC

4 3/4

4 3/4

3 5/16

5 3/4

5 3/4

5 3/8

6 3/4

4 3/4

4 5/8

3

-

2

1/4

7

XJM

6 3/4

6 3/4

10 3/16

7 3/4

7 3/4

11 11/16

9 1/8

6 1/4

7

-

-

2

3/8

22 1/2

XJMGC**

6 3/4

6 3/4

9 1/8

7 3/4

7 3/4

11 1/2

9 1/8

6 1/4

7

5 1/4

5 3/8

2

3/8

22 1/2

XJMA

6 13/16

6 13/16

7 3/16

7 13/16

7 13/16

8 11/16

9 1/8

6 1/4

7

-

-

2

3/8

17

XJMAGC**

6 13/16

6 13/16

6 1/8

7 13/16

7 13/16

8 1/2

9 1/8

6 1/4

7

5 1/4

5 1/4

2

3/8

17

XJMC

6 3/4

6 3/4

5 3/16

7 13/16

7 13/16

6 11/16

9 1/8

6 1/4

7

-

-

2

3/8

13 1/2

XJMCGC**

6 3/4

6 3/4

4 1/8

7 13/16

7 13/16

6 1/2

9 1/8

6 1/4

7

5 1/4

5 3/8

2

3/8

13 3/4

6A–12

XJHA

7 3/16

9 3/16

5 1/4

8 3/16

10 3/16

6 3/4

9 3/4

8 3/4

7

-

-

2

1/2

16 1/2

XJHAD6

7 3/16

9 3/16

11

8 3/16

10 3/16

12 7/16

9 3/4

8 3/4

7

-

-

2

1/2

19 3/4
21 1/2

XJHAD9

7 3/16

9 3/16

14

8 3/16

10 3/16

15 7/16

9 3/4

8 3/4

7

-

-

2

1/2

XJHAD12

7 3/16

9 3/16

17

8 3/16

10 3/16

18 7/16

9 3/4

8 3/4

7

-

-

2

1/2

23 1/2

XJHAGC

7 3/16

9 3/16

4 3/16

8 3/16

10 3/16

6 9/16

9 3/4

8 3/4

7

5 1/4

-

2

1/2

16 1/2

XJHB

7 1/4

9 1/8

7 1/4

8 3/8

10 1/4

8 13/16

9 3/4

8 7/8

7

-

-

2

1/2

22

XJHBGC

7 1/4

9 1/8

6 3/16

8 3/8

10 1/4

8 9/16

9 3/4

8 7/8

7

5 1/4

-

2

1/2

22

Note: Suffix H, X and HX enclosure types are dimensionally identical. **Includes built-in meter mounting provisions; call factory for details.
224
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 225

Explosionproof Enclosures With Threaded Cover
Base

Inside Nominal

Overall

Mounting

Cover

Window

Flange

Catalog

Dimensions

Dimensions

CL to CL

Opening

Viewing

Opening Conduit Bolt

Dia.

Dia.

Number

W

L

D

A

B

C

E

F

Dia.

Max. Mount.
Size

Size

Ship.
Wt.
Pounds

XJHC

7 3/4

10 5/16

6 3/16

8 7/8

11 7/16

7 3/4

10 1/4

7 3/4

7

-

-

2

1/2

23 1/2

XJHCD6

7 3/4

10 5/16

11 15/16

8 7/8

11 7/16

13 7/16

10 1/4

7 3/4

7

-

-

2

1/2

26 3/4

XJHCD9

7 3/4

10 5/16

14 15/16

8 7/8

11 7/16

16 7/16

10 1/4

7 3/4

7

-

-

2

1/2

28 1/2

XJHCD12

7 3/4

10 5/16

17 15/16

8 7/8

11 7/16

19 7/16

10 1/4

7 3/4

7

-

-

2

1/2

30 1/2

XJHCGC

7 3/4

10 5/16

5 1/8

8 7/8

11 7/16

7 9/16

10 1/4

7 3/4

7

5 1/4

-

2

1/2

23 1/2

XJK

9 1/2

11 1/2

7 1/4

10 3/4

12 3/4

9 1/4

12 1/4

8

9

-

-

3

1/2

39 1/4

XJKD6

9 1/2

11 1/2

13 1/16

10 3/4

12 3/4

14 15/16

12 1/4

8

9

-

-

3

1/2

43 3/4

XJKD12

9 1/2

11 1/2

19 1/16

10 3/4

12 3/4

20 15/16

12 1/4

8

9

-

-

3

1/2

49

XJKD18

9 1/2

11 1/2

25 1/16

10 3/4

12 3/4

26 15/16

12 1/4

8

9

-

-

3

1/2

54 3/4

XJKGC

9 1/2

11 1/2

6 3/16

10 3/4

12 3/4

9 1/16

12 1/4

8

9

6 11/16

-

3

1/2

39 1/4

XJKA

9 1/2

11 1/2

9 1/8

10 3/4

12 3/4

11 3/16

12 3/8

8

9

-

-

3

1/2

45 3/4

XJKAD6

9 1/2

11 1/2

15

10 3/4

12 3/4

16 13/16

12 3/8

8

9

-

-

3

1/2

50 1/4

XJKAD12

9 1/2

11 1/2

21

10 3/4

12 3/4

22 13/16

12 3/8

8

9

-

-

3

1/2

55 1/4

XJKAD18

9 1/2

11 1/2

27

10 3/4

12 3/4

28 13/16

12 3/8

8

9

-

-

3

1/2

61 1/4

XJKAGC

9 1/2

11 1/2

8 1/16

10 3/4

12 3/4

11

12 3/8

8

9

6 11/16

-

3

1/2

45 3/4

14 5/8

9 13/16

15 3/8

9

10 11/16

-

-

4

1/2

60 1/2

14 13/16 15 15/16

15 3/8

9

10 11/16

-

-

4

1/2

87 1/2

XJN6

11 1/2

12 3/4

7 7/16

13 3/8

XJN12

11 1/2

12 3/4

13 9/16

13 9/16

XJNGC6

11 1/2

12 3/4

6 3/16

13 3/8

14 5/8

9 7/8

15 3/8

9

10 11/16

8

-

2

1/2

60 1/2

XJNGC12

11 1/2

12 3/4

12 5/16

13 9/16

14 13/16

16

15 3/8

9

10 11/16

8

-

2

1/2

87 1/2

XJWH

6 5/8 DIA

4 3/8

7 15/16

7 15/16

5 15/16

6 3/8

6 3/8

7

-

-

2

3/8

11 1/2

XJWH6

6 5/8 DIA

10 1/8

7 15/16

7 15/16

11 5/8

6 3/8

6 3/8

7

-

-

2

3/8

14 3/4

XJWH9

6 5/8 DIA

13 1/8

7 15/16

7 15/16

14 5/8

6 3/8

6 3/8

7

-

-

2

3/8

16 1/2

XJWH12

6 5/8 DIA

16 1/8

7 15/16

7 15/16

17 5/8

6 3/8

6 3/8

7

-

-

2

3/8

18 1/2

XJWHGC

6 5/8 DIA

3 5/16

7 15/16

7 15/16

5 3/4

6 3/8

6 3/8

7

5 1/4

-

2

3/8

11 1/2

XJW3

4 7/8 DIA

5 5/16

5 11/16

5 11/16

6 7/8

4 1/2

4 1/2

4 7/8

-

-

1 1/4

1/4

5

XJW5

4 7/8 DIA

7 5/16

5 11/16

5 11/16

8 11/16

4 1/2

4 1/2

4 7/8

-

-

1 1/4

1/4

5 3/4

XJWT

5 3/8 DIA

3 13/16

6 3/8

6 3/8

5 1/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

8

XJWT4

5 3/8 DIA

7 9/16

6 3/8

6 3/8

8 7/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

9

XJWT6

5 3/8 DIA

9 1/16

6 3/8

6 3/8

10 3/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

9 1/2

XJWT10

5 3/8 DIA

13 9/16

6 3/8

6 3/8

14 7/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

11

XJWT13

5 3/8 DIA

16 9/16

6 3/8

6 3/8

17 7/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

12

XJWTGC

5 3/8 DIA

2 15/16

6 3/8

6 3/8

5 1/8

5 1/8

5 1/8

5 3/8

4

-

2

5/16

8

XJSWGC**
XJOGC

5 1/4

5 1/4

4 1/16

6 1/8

6 1/8

5 5/8

7 1/8

4 3/4

5

3 3/8 x 3 3/8

3 3/4

3/4

5/16

8

8

8

5 1/4

9

9

7 9/16

8

8

7

5 1/4

-

2

5/16

20 1/4

6A–13

Note: Suffix H, X and HX enclosure types are dimensionally identical. **Includes built-in meter mounting provisions; call factory for details.

225
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 226

Conduit Drilling and Tapping Guidelines For Threaded Enclosure

When drilling & tapping enclosures for conduit, proper installation requires compliance with the following:
1. Must be tapped with at least 5 full NPT threads (suffix X enclosures require 6 NPT threads) in enclosure back
or sides only; min. 1/2" conduit size.
2. Tapping depth of NPT holes must be plus 1/2 turn min. to plus 1-1/2 turns max. past standard NPT plug gage notch.
3. Inner end of conduit openings shall be smooth and well-rounded.

TABLE I
Trade Size Of

Minimum wall thickness at

Conduit, Inches (NPT)

conduit entrance excluding
suffix X enclosures (XCEX)

1/2 - 3/4

3/8 inch

1-2

7/16 inch

2 1/2 - 5

5/8 inch

TABLE II
Conduit size, inches (NPT)

1/2

3/4

1

1 1/4

1 1/2

2

2 1/2

3

3 1/2

4

Minimum Distance from conduit CL
to inside corner or back of box

1 5/16

1 7/16

1 9/16

1 3/4

1 7/8

2 1/8

2 3/8

2 11/16

2 15/16

3 1/4

Approximate diameter of union

1 7/8

1 7/8

2 1/16

2 7/8

3 1/4

3 7/8

4 7/8

5 1/2

6

6 1/2

TABLE III
NPT (METRIC) THREADS
SIZE

5

4

3 1/2

3
(M75)

2 1/2
(M63)

2
(M50)

1 1/2
(M40)

1 1/4
(M32)

1
(M25)

3/4
(M20)

1/2
(M16)

1/16 - 3/8

1/16-3/8
NPT

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

1 1/8

1/2
(M16)

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

3/4
(M20)

4 1/2

3 3/4

3 1/2

3 1/8

2 3/4

2 1/2

2 1/8

2

1 3/4

1 1/2

1
(M25)

4 5/8

3 7/8

3 5/8

3 1/4

2 7/8

2 3/4

2 1/4

2 1/8

1 7/8

1 1/4
(M32)

4 7/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2
(M40)

5

4 1/4

4

3 5/8

3 1/4

3

2 5/8

2
(M50)

5 3/8

4 3/4

4 1/2

4

3 5/8

3 3/8

2 1/2
(M63)

5 1/2

4 7/8

4 5/8

4 1/4

3 7/8

3
(M75)

5 7/8

5 1/4

5

4 5/8

3 1/2

6 1/4

5 3/4

5 1/2

4

6 7/8

6

5

7 3/8

This information is compiled from data which we believe is reliable and is given
in good faith. Since the methods of application and conditions under which our
products are used are beyond our control, we are not able to guarantee the
application and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

6A–14

Note: All dimensions are in inches.
The Adalet engineering department is available to provide custom
explosionproof enclosures for your products.
226
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 227

Explosionproof Enclosures With Threaded Cover
METER & INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
DRILLING & TAPPING LAYOUT INSTRUCTIONS
Consult factory for extensive machining options, i.e.
mounting of operators, thread type and size thru wall, mounting pans.
Layout data sheets available.
MINIMUM DISTANCE BETWEEN CENTERS OF AUXILIARY DEVICES AND CONDUIT ENTRIES
SIZE

5
NPSM

4
NPSM

3 1/2
NPSM

3
NPSM

2 1/2
NPSM

2
NPSM

1 1/2
NPSM

1 1/4
NPSM

1
NPSM

3/4
NPSM

1/4-3/8
NPSM

1/4-1 UN

1/16-3/8
NPT

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

1 1/8

1/2NPT
(M16)

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

3/4 NPT
(M20)

4 1/2

3 3/4

3 1/2

3 1/8

2 3/4

2 1/2

2 1/8

2

1 3/4

1 1/2

1 NPT
(M25)

4 5/8

3 7/8

3 5/8

3 1/4

2 7/8

2 3/4

2 1/4

2 1/8

1 7/8

1 1/4 NPT
(M32)

4 7/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2 NPT
(M40)

5

4 1/4

4

3 5/8

3 1/4

3

2 5/8

5 3/8

4 3/4

4 1/2

4

3 5/8

3 3/8

5 1/2

4 7/8

4 5/8

4 1/4

3 7/8

3 NPT
(M75)

5 7/8

5 1/4

5

4 5/8

3 1/2
NPT

6 1/4

5 3/4

5 1/2

4
NPT

6 7/8

6

5
NPT

7 3/8

2 NPT
(M50)
2 1/2 NPT
(M63)

MINIMUM DISTANCE BETWEEN CENTERS OF AUXILIARY DEVICES
5
NPSM

4
NPSM

3 1/2
NPSM

3
NPSM

2 1/2
NPSM

2
NPSM

1 1/2
NPSM

1 1/4
NPSM

1
NPSM

3/4
NPSM

1/4-3/8
NPSM

1/4-1 UN

1/4-1 UN

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

1 1/8

1/4-3/8
NPSM

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

3/4
NPSM

4 1/2

3 3/4

3 1/2

3 1/8

2 3/4

2 1/2

2 1/8

2

1 3/4

1 1/2

1
NPSM

4 5/8

3 7/8

3 5/8

3 1/4

2 7/8

2 3/4

2 1/4

2 1/8

1 7/8

1 1/4
NPSM

4 7/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2
NPSM

5

4 1/4

4

3 5/8

3 1/4

3

2 5/8

2
NPSM

5 3/8

4 3/4

4 1/2

4

3 5/8

3 3/8

2 1/2
NPSM

5 1/2

4 7/8

4 5/8

4 1/4

3 7/8

3
NPSM

5 7/8

5 1/4

5

4 5/8

3 1/2
NPSM

6 1/4

5 3/4

5 1/2

4
NPSM

6 7/8

6

5
NPSM

7 3/8

6A–15

SIZE

227
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 228

Quick Reference Guide
METHODS OF PROTECTION
Area
Division 1

Division 2

Area
Zone 0
Zone 1

Zone 2

Protection Method

UL

CSA

CENELEC

Explosionproof
Intrinsically Safe
(2 Fault)
Purge/Pressurized
(Type X or Y)
Nonincendive
Non-sparking device
Purge/Pressurized
(Type Z)
Hermetically sealed
Any Class I,
Division 1 Method
Protection Method
Intrinsically Safe 'ia'
(2 Fault)
Flameproof 'd'
Increased Safety 'e'
Intrinsically Safe 'ib'
(1 Fault)0
Encapsulation 'm'
Oil Immersion 'o'
Purged/Pressurized 'p'
Powder filling 'q'
Any Zone 0 Method
Non-sparking 'nA'
Hermetically sealed 'nC'
Nonincendive 'nC'
Restricted breathing 'nR'
Any Zone 0 or 1 Method

ANSI/UL 1203

CSA-30

--

--

ANSI/UL 913

CSA-157

--

--

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604
UL 1604

CSA-213
CSA-213

---

---

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604

CSA-213

--

--

--

--

--

--

UL (AEx)

CSA (Ex)

CENELEC (EEx)

IEC (Ex)

UL 2279 Pt. 11

CSA-E79-18

EN 50028

IEC 60 079-18

UL 2279 Pt. 1
UL 2279 Pt. 7

CSA-E79-1
CSA-E79-7

EN 50018
EN 50019

IEC 60 079-1
IEC 60 079-7

UL 2279 Pt. 11

CSA-E79-11

EN 50020

IEC 60 079-11

UL 2279 Pt. 18
UL 2279
UL 2279 Pt. 2
UL 2279
-UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
--

CSA-E79-18
CSA-E79-6
CSA-E79-2
CSA-E79-5
-CSA-E79-15
CSA-E79-15
CSA-E79-15
CSA-E79-15
--

EN 50028
EN 50015
EN 50016
EN 50017
-prEN 50021
prEN 50021
prEN 50021
prEN 50021
--

IEC 60 079-18
IEC 60 079-6
IEC 60 079-2
IEC 60 079-5
-IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
--

TEMPERATURE CLASSES

AREA CLASSIFICATIONS
Ignitable Materials
Present Continuously

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Zone 0
(Zone 20 Dust)
Zone 0
Division 1

Zone 1
(Zone 21 Dust)
Zone 1
Division 1

Zone 2
(Zone 22 Dust)
Zone 2
Division 2

IEC/CENELEC
NEC 505
NEC 500

ATEX Classification by Group & Category According to Use
Ignitable Materials
Present Continuously
Equipment Group II Category 1 Equipment
(surface)
Equipment Group I
Category M1 Equipment
(mining)

IEC

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Category 2 Equipment

Category 3 Equipment

Category M2 Equipment

—

GAS GROUPINGS
Gas, Dust or Fiber

NEC 505/IEC/CENELEC

NEC 500

Acetylene
Hydrogen
Ethylene
Propane
Methane
Metal Dust
Coal Dust
Grain Dust
Fibers

Group IIC
Group IIC/Group IIB+H2
Group IIB
Group IIA
Group I (firedamp)
None
None
None
None

Class I/Group A
Class I/Group B
Class I/Group C
Class I/Group D
Class I/Group D
Class II/Group E
Class II/Group F
Class II/Group G
Class III

ACRONYMS
CENELEC - European Committee for Electrotechnical Standardization
IEC - International Electrotechnical Commission
NEC - National Electrical Code
U.L. - Underwriters Laboratories
C.S.A. - Canadian Standards Association
FM - Factory Mutual
BASEEFA - British Approvals Service for Electrical Apparatus in
Flammable Atmospheres
NFPA - National Fire Protection Agency
ISO - International Organization for Standardization
ANSI - American National Standard Institute
ATEX - Atmospheres Explosibles

Maximum
Surface
Temperature

NEC 505
IEC
CENELEC

450°C
300°C
280°C
260°C
230°C
215°C
200°C
180°C
165°C
160°C
135°C
120°C
100°C
85°C

T1
T2

T3

T4
T5
T6

NEC 500
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

INGRESS PROTECTION (IP XX) CODES
#

First Number
(Protection against Solid Bodies)

Second Number
(Protection against Liquids)

0
1
2
3
4
5
6
7
8

No protection
Objects greater than 50mm
Objects greater than 12mm
Objects greater than 2.5mm
Object greater than 1mm
Dust Protected
Dust-tight
---

No protection
Vertically dripping water
75-90 Deg. dripping water
Sprayed water
Splashed water
Water jets
Heavy seas
Effects of immersion
Indefinite immersion

7A–1

15599 Sec.7 12/9/01 11:14 AM Page 229

FS Control3 Specifications

FS Control3
We named this line of control stations FS Control3
because we offer it in three different material types –
carbon steel, stainless steel and fiberglass – to meet
your control station needs. Each material type has certain

properties and characteristics that make it well-suited for
certain applications. If you would like assistance in
determining which enclosure type best fits your
application, please consult our engineering department.

Features and Benefits

Compliances

• The normally open/normally closed factory sealed contact
block is rated both NEMA A600 and NEMA Q300

X2CS, X2SS, and X2FG Series:
UL Standard 698, 1604 and 2279
Canadian Standards Association C22.2 No. 213-M1987
NEC Class I, Division 2, Groups ABCD; Class II, Division 2,
Groups FG; Class III
NEC Class I, Zone 2, Group IIC

• Electrical ratings for pilot lights range between 6 volts
and 480 volts
• Carbon steel, stainless steel and fiberglass control station
enclosure types available in one- through four-hole
arrangements to accommodate a wide variety of system
needs. Other configurations are available - consult factory

X2CS Series:
NEMA Type 3, 3R, 7ABCD (Division 2), 12 and 13, 4

• Conduit hub entries available in 1/2", 3/4" and 1" sizes
either dead-end or feed through

X2FG and X2SS Series:
NEMA Type 3, 3R, 4, 4X, 7ABCD (Division 2), 12, 13

• Broad new line of 30mm industrial pilot lights,
pushbuttons and selector switches allows thousands of
possible control station configurations

Factory Sealed Contact Block:
Underwriters Laboratories – UL698, UL 1203, UL1604 and
UL2279
Class I, Division 1, Groups ABCD
Class I, Zone 1, Group IIC
Class I, Division 2, Groups ABCD
Class I, Zone 2, Group IIC
Canadian Standards Association C22.2 No. 213-M1987
Class I, Div. 2, Groups BCD

• High-quality legend plates permit easy identification of
device function

Material/Finish
• Enclosures:
X2CS – Made from 14 ga. cold-rolled steel with
continuously welded seams ground to a smooth finish.
Each X2CS enclosure comes complete with a grounding
stud and wall mounting back brackets welded to the
outside top and bottom. Phosphatized and finished inside
and out with ANSI/ASA 61 gray polyester powder coating.

Pilot Lights:
Listed Underwriters Laboratories:
Class I, Division 2, Groups ABCD

X2SS – Made from 14 ga. Type 304 stainless steel with
continuously welded seams ground to a smooth finish.
Each X2SS comes complete with a grounding stud and
wall mounting brackets welded to the outside top and
bottom. Finished with #4 brush.
X2FG – Made from compression-molded, fiberglassreinforced polyester. Each X2FG comes complete with a
grounding strap and optional mounting brackets can be
provided. Molded standard machine tool gray.

Certifications
LISTED

X2CS Series:
Type 12, 4

• Industrial Pilot Device Bodies: PBT Polyester
• Industrial Pilot Device Caps: PBT Polyester

X2FG and X2SS Series:
Type 3, 4X, 12 and 13

• Industrial Pilot Device Clamp Rings: Polyester (standard)
or aluminum

Application
• For installation in Division 2 areas of chemical and petrochemical plants, refineries and other process industries
where flammable vapors, gases or combustible dust may
be present due to accidental or abnormal operation

LISTED

• For use with Adalet 30mm pushbuttons, selector
switches and pilot lights to provide circuit/motor control
and/or electrical status indication
LISTED

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

X2CS, X2SS, and X2FG Series:
Listed Underwriters Laboratories:
Class I, Division 2, Groups BCD; Class I, Zone 2, Group IIB+H2;
Class II, Division 2, Groups FG;

Factory Sealed Contact Block:
Listed Underwriters Laboratories:
Class I, Division 2, Groups BCD
Class I, Zone 2, Group IIB+H2
Certified Canadian Standards Association Class I, Div. 2,
Groups BCD
Pilot Lights:
Listed Underwriters Laboratories:
Class I, Division 2, Groups ABCD

229

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 230

7A–2

Pushbutton Operators for Use with FS Control3
Pushbutton Operators with Polyester Clamp Ring
Cap Color
Green
Black
Red

Flush Cap

Suffix

Extended Cap

Suffix

Mushroom Cap

Suffix

PBO-FCGN-FS
PBO-FCBK-FS
PBO-FCRD-FS

1TS
2TS
3TS

PBO-XCGN-FS
PBO-XCBK-FS
PBO-XCRD-FS

4TS
5TS
6TS

PBO-MCGN-FS
PBO-MCBK-FS
PBO-MCRD-FS

7TS
8TS
9TS

For additional NO/NC contact block add “/FS” to end of catalog number
For aluminum clamp ring, add “A” after first dash in catalog number.
Example – PBO-AXCRD-FS is red extended cap pushbutton with aluminum clamp ring.
Note: Caps and operating heads are available in a variety of styles and colors –
please consult factory

Maximum Ampere Rating Control Circuit Contacts Type FSBT
AC (A600) 600 VAC max

DC (Q300)

Volts

110

220

440

550

120

240

Make & Interrupting Capacity
Normal Load Break
Continuous Current

60
6
10

30
3
10

15
1.5
10

12
1.2
10

.55
.55
2.5

.27
.27
2.5

Catalog No.

FSBT

One Normally Open and One Normally Closed.

Illuminated Pushbuttons Unit Complete Less Cap1
Type

Volts

Transformer 50/60 Hz

Full Voltage Type

Neon Type

2

Incandescent

LED Resistor Type

4

Dual Input Remote Test

Catalog Number

Suffix

AC
AC
AC
AC 3

TFLU120FS
TFLU240FS
TFLU480FS
TFLU277FS

10TS
11TS
12TS
13TS

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC

FVLU6FS
FVLU12FS
FVLU24FS
FVLU120FS

14TS
15TS
16TS
17TS

120 AC/DC
240 AC/DC
480 AC/DC

FVLU120NFS
FVLU240NFS
FVLU480NFS

18TS
19TS
20TS

120 AC/DC
240 AC/DC

RLU120IFS
RLU240IFS

21TS
22TS

120 AC/DC
240 AC/DC

RLU120LFS
RLU240LFS

23TS
24TS

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC
240 AC/DC

RTLU6FS
RTLU12FS
RTLU24FS
RTLU120FS
RTLU240FS

25TS
26TS
27TS
28TS
29TS

120
240
480
277

Color Caps for Illuminated
Pushbuttons 5
Color Cap with Polyester Clamp Ring
Color
Amber
Blue
Clear
Green
Red
White

Catalog Number

Suffix

IPBCAR
IPBCBE
IPBCCR
IPBCGN
IPBCRD
IPBCWE

30TS
31TS
32TS
33TS
34TS
35TS

For aluminum clamp ring, add “A” prefix to
color cap catalog number. Example – AIPBCBE
is blue color cap for illuminated pushbutton
with aluminum clamp ring.

Footnotes
1 To order as an assembled illuminated
pushbutton with color cap, add color cap
catalog number to the end of illuminated
pushbutton catalog number.
Example – TFLU120FS-IPBCRD would be
complete illuminated pushbutton with red cap.

2 Neon lights are available with red or green
lamps. Add suffix letter “R” or “G”
respectively to designate color. Use amber,
clear or red cap only for red neon lights; green
or clear cap only for green neon lights.

3 120 Volt incandescent lamps are not
recommended when the unit is subjected to
shock and/or vibration. A transformer, resistor,
neon or LED unit will provide longer lamp life.

4 Specify LED lamp color. Add suffix letter “R”
for red, “G” for green and “Y” for yellow
(amber). Use amber, clear or red cap only for
red lights; green or clear cap only for green
lights; red, clear or amber for yellow lights.

5 Catalog numbers are for extended color caps.
For flush guarded color caps, add suffix
“EECR” to the catalog number.

230
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7A–3

15599 Sec.7 12/9/01 11:14 AM Page 231

Push-Twist/Push-Pull Operators for Use with FS Control3

2 Position Push-Twist Release
Maintained Operators Non-Illuminated

2 Position Push-Pull
Maintained Operators Non-Illuminated

Maintained In/Maintained Out
Color
Black
Red
Green
Yellow

Maintained In/Maintained Out

Catalog Number

Suffix

Color

PTR-TMCBK-FS
PTR-TMCRD-FS
PTR-TMCGN-FS
PTR-TMCYW-FS

36TS
37TS
38TS
39TS

Black
Red
Green
Yellow

Catalog Number

Suffix

PBO-PPMCBK-FS
PBO-PPMCRD-FS
PBO-PPMCGN-FS
PBO-PPMCYW-FS

40TS
41TS
42TS
43TS

For aluminum clamp ring, add “A” after first dash in catalog number.
Example – PTR-ATMCGN-FS is 2 position push-twist release operator with
green cap and aluminum clamp ring.

For aluminum clamp ring, add “A” after first dash in catalog number.
Example – PBO-APPMCYW-FS is 2 position push-pull operator with yellow
cap and aluminum clamp ring.

Note: For additional NO/NC contact block add “/FS” to end of
catalog number.

Note: For additional NO/NC contact block add “/FS” to end of
catalog number.

2 Position Push-Pull Release
Maintained Operators Illuminated
Maintained In/Maintained Out
Type
Transformer 60/50 Hz

Full Voltage

Incandescent Resistor

Volts

Catalog Number

Suffix

TFPPM120-IMCRD-FS
TFPPM240-IMCRD-FS
TFPPM480-IMCRD-FS
TFPPM600-IMCRD-FS

44TS
45TS
46TS
47TS

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC
120 AC/DC Neon

FVPPM6-IMCRD-FS
FVPPM12-IMCRD-FS
FVPPM24-IMCRD-FS
FVPPM120-IMCRD-FS
FVPPM120NR-IMCRD-FS

48TS
49TS
50TS
51TS
52TS

120 AC/DC
240 AC/DC

RLPPM120-IMCRD-FS
RLPPM240-IMCRD-FS

53TS
54TS

120
240
480
600

AC
AC
AC
AC

For aluminum clamp ring, add “A” after first dash in catalog number.
Example – FVPPM6-AIMCRD-FS is full voltage 2 position push-pull release illuminated operator
with aluminum clamp ring.
Note: Standard color cap on 2 position push-pull illuminated operator is red. Additional
color caps are available – please consult factory.

231
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 232

7A–4

Selector Switch Units for Use with FS Control3
(STANDARD)
MOUNTING
POSITION A

MOUNTING
POSITION B
CONTACT BLOCK SHOWN
MOUNTED IN POSITION B

VIEWED FROM BACK

2 Position Selector Switch Units Assembled with Polyester Clamp Ring (partial listing)1
Mounting
Position

Contact
Symbol

A &B

Handle Position
Left / Right
O=Open, X=Closed

O X
X O

Type of Operator

Maintained Position

Suffix

Spring Return –
Right to Left

Suffix

Spring Return –
2
Left to Right

Suffix

Standard

SS02-SHWE-FS

55TS

SRORL-SHWE-FS

60TS

SROLR-SHWE-FS

63TS

Lever

SS02-SLWE-FS

56TS

SRORL-SLWE-FS

61TS

SROLR-SLWE-FS

64TS

Key Locking Pos
Left
Right
Both

K0SS2-KL-FS
K0SS2-KR-FS
K0SS2-KLR-FS

57TS
58TS
59TS

KOSRRL-KLFS
—
—

62TS

—
—
—

For aluminum clamp ring on standard or lever, add “A” after first dash in catalog number. Example – SS02-ASHWE-FS is standard 2 position selector switch unit
maintained position with aluminum clamp ring. For aluminum clamp ring on key, add “A” to beginning of catalog number. Example – AKOSS2-KL-FS is 2 position
key selector switch key locking left with aluminum clamp ring. Optional contact sequences available upon request. Contact block mounted standard in “A”
position. To order additional contact block for “B” mounting position, add “/FS” to the end of the catalog number.

3 Position Selector Switch Units Assembled with Polyester Clamp Ring (partial listing)1
Mounting
Position

Contact
Symbol

Handle Position
Left /Center/Right
O=Open, X=Closed

X O O
O X O

A

O O X
O X O

B

Spring Return –
Left to Center

Suffix

Spring Return –
Right to Center

Maintained Position

Suffix

Standard

SSO3-SHWE-FS

65TS

SRORLC-SHWE-FS 73TS

SRORC-SHWE-FS 81TS SROLRC-SHWE-FS

89TS

Lever

SS03-SLWE-FS

66TS

SRORLC-SLWE-FS 74TS

SRORC-SLWE-FS 82TS SROLRC-SLWE-FS

90TS

Key Locking Pos
Left
Right
Both

K0SS3-KL-FS
K0SS3-KR-FS
K0SS3-KC-FS

67TS
68TS
69TS

KOSRLC-KL-FS
KOSRLC-KR-FS
KOSRLC-KC-FS

75TS
76TS
77TS

Key Locking Pos
Left & Right
Left & Center
Right & Center

KOSS3-KLR-FS
KOSS3-KLC-FS
KOSS3-KRC-FS

70TS
71TS
72TS

KOSRLC-KLR-FS
KOSRLC-KLC-FS
KOSRLC-KRC-FS

78TS
79TS
80TS

KOSRRC-KL-FS
KOSRRC-KR-FS
KOSRRC-KC-FS

Suffix

Spring Return –
Either to Center

Type of Operator

83TS
84TS
85TS

KOSRLRC-KL-FS
KOSRLRC-KR-FS
KOSRLRC-KC-FS

KOSRRC-KLR-FS 86TS KOSRLRC-KLR-FS
KOSRRC-KLC-FS 87TS KOSRLRC-KLC-FS
KOSRRC-KRC-FS 88TS KOSRLRC-KRC-FS

Suffix

91TS
92TS
93TS

94TS
95TS
96TS

For aluminum clamp ring on standard or lever, add “A” after first dash in catalog number. Example – SSO3-ASLWE-FS is lever 3 position selector switch unit
maintained position with aluminum clamp ring. For aluminum clamp ring on key, add “A” to beginning of catalog number. Example – AKOSS3-KLR-FS is 3
position key selector switch key locking left and right with aluminum clamp ring. Optional contact sequences available upon request. Specific key removable
positions are available – consult factory. Contact block mounted standard in “A” position. To order additional contact block for “B” mounting position, add “/FS”
to the end of the catalog number.

Footnotes
1 Catalog numbers for standard and lever
operators identify black operators with white
color insert. Consult factory for other available
colors.

2 Spring Return Left to Right uses a reverse cam
and the contact block selection is the opposite
as shown as standard.

232
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7A–5

15599 Sec.7 12/9/01 11:14 AM Page 233

Pilot Lights for Use with FS Control3

Standard Pilot Lights Unit Complete Less Cap
Type

Volts

Catalog Number

Suffix

TFLU120
TFLU240
TFLU480
TFLU277

97TS
98TS
99TS
100TS

FVLU6
FVLU12
FVLU24
FVLU120

101TS
102TS
103TS
104TS

120 AC/DC
240 AC/DC
480 AC/DC

FVLU120N
FVLU240N
FVLU480N

105TS
106TS
107TS

120 AC/DC
240 AC/DC

RLU120I
RLU240I

108TS
109TS

120 AC/DC
240 AC/DC

RLU120L
RLU240L

110TS
111TS

120 AC/DC
240 AC/DC

RTLU120
RTLU240

112TS
113TS

Transformer 50/60 Hz

Full Voltage Type

Neon Type

AC
AC
AC
AC

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC 2

1

Incandescent

LED Resistor Type

120
240
480
277

3

Dual Input Remote Test

Footnotes

Color Cap with Polyester Clamp Ring
Color

Catalog Number

Suffix

PLLAR
PLLBE
PLLCR
PLLGN
PLLRD
PLLWE

126TS
127TS
128TS
129TS
130TS
131TS

Amber
Blue
Clear
Green
Red
White

For aluminum clamp ring, add “A” prefix to
color cap catalog number. Example – APLLBE
is blue color cap for standard pilot light with
aluminum clamp ring.

LED Lamps

1 Neon lights are available with red or green

shock and/or vibration. A transformer, resistor,
neon or LED unit will provide longer lamp life.

lamps. Add suffix letter “R” or “G”
respectively to designate color. Use amber,
clear or red cap only for red neon lights; green
or clear cap only for green neon lights.

3 Specify LED lamp color. Add suffix letter “R”
for red, “G” for green and “Y” for yellow
(amber). Use amber, clear or red cap only for
red lights; green or clear cap only for green
lights; red, clear or amber for yellow lights.

2 120 Volt incandescent lamps are not
recommended when the unit is subjected to

Push-to-Test Pilot Lights Unit Complete Less Cap
Type
Transformer 50/60 Hz

Full Voltage Type

Neon Type

Color Caps
for Standard Pilot Lights

1

Incandescent Resistor Type
LED Resistor Type

3

Volts

Catalog Number

Suffix

120 AC
240 AC
480 AC

TFPTT120FS
TFPTT240FS
TFPTT480FS

114TS
115TS
116TS

6 AC/DC
12 AC/DC
24 AC/DC
2
120 AC/DC

FVPTT6FS
FVPTT12FS
FVPTT24FS
FVPTT120FS

117TS
118TS
119TS
120TS

120 AC/DC
240 AC/DC
480 AC/DC

FVPTT120NFS
FVPTT240NFS
FVPTT480NFS

121TS
122TS
123TS

120 AC/DC

RLPTT120FS

124TS

120 AC/DC

RLPTT120LFS

125TS

Footnotes
1 Neon lights are available with red or green
lamps. Add suffix letter “R” or “G”
respectively to designate color. Use amber,
clear or red cap only for red neon lights; green
or clear cap only for green neon lights.

2 120 Volt incandescent lamps are not
recommended when the unit is subjected to
shock and/or vibration. A transformer, resistor,
neon or LED unit will provide longer lamp life.

3 Specify LED lamp color. Add suffix letter “R”
for red, “G” for green and “Y” for yellow
(amber). Use amber, clear or red cap only for
red lights; green or clear cap only for green
lights; red, clear or amber for yellow lights.

4 Catalog numbers are for extended color caps.
For flush guarded color caps, add suffix
“EECR” to the catalog number.

Transformer lights and full voltage 6, 12 and
24 volt lights can be provided with solid state
long life LED lamps in place of the standard
incandescent lamps. Adalet’s LED lamps are
in a miniature bayonet base for direct
interchangeability and feature an ultra bright
4 LED cluster with light output comparable to
a standard type 755 incandescent lamp. The
4 LEDs are built into two circuits for
redundancy and include internal current
limiting resistors. Lamps are available in red,
green, and yellow.

How to Order
Add the letter “L” plus the first letter of the
color to the light catalog number.

Example: Catalog number TFLU120LR
would be a transformer light with red LED
lamp.

Color Caps
for Push-to-Test Pilot Lights

4

Color Cap with Polyester Clamp Ring
Color
Amber
Blue
Clear
Green
Red
White

Catalog Number Suffix
IPBCAR
IPBCBE
IPBCCR
IPBCGN
IPBCRD
IPBCWE

30TS
31TS
32TS
33TS
34TS
35TS

For aluminum clamp ring, add “A” prefix to
color cap catalog number. Example – AIPBCBE
is blue color cap for push-to-test pilot light with
aluminum clamp ring.

233
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 234

7A–6

Legend Plates for Use with FS Control3

Standard Legend Plates
Description

Catalog Number
Prefix

Standard
Narrow
Short

LP
LPN
LPS

Height (inches)

Width (inches)

Characters
Per Line

Number of Lines

2
2

2
1 3/4
2

16
16
16

2
2
2

1 3/4

Legend plates are available in the three styles listed above plus the IEC standard emergency
legend plate shown to the right. Standard is black background with white letters except -05
and -28 which are red background with white letters. Other colors are available – consult
factory. Plates with special legends are available – consult factory.

Standard Legends
Pushbuttons and Lights

2 Position Selector

3 Position Selector

Catalog No.
Suffix

Legend Left

Legend Right

Catalog No.
Suffix

Legend Left

Legend Center

Legend Right

Catalog No.
Suffix

01
02
03
04

Auto
Auto
Down
Fast

Hand
Manual
Up
Slow

50
68
51
63

Down
Fwd
Fwd
Hand

Off
Auto
Off
Off

Up
Rev
Rev
Auto

80
81
82
83

05

Fwd

Rev

52

Manual

Off

Auto

84

Fast
Forward
Hand
Inch
Jog

06
07
08
09
10

Hand
Inch
Manual
Off
On

Auto
Run
Auto
On
Off

53
54
55
56
57

Off
Off
Off
1
1

Run
Start
1
Off
2

Start
Run
2
2
3

89
85
86
87
88

Manual
Motor Run
Off
On
Overload

11
26
12
13
27

Open
Push On
Pull Start
Push Off
Push to Stop

Close
Push Off
Push Stop
Pull On
Pull to Start

58
64
65
66
67

Open
Power Off
Power On
Push-to-Reset
Push-to-Test

14
15
16
30
17

Rev
Run
Slow
Start
Stop

Fwd
Jog
Fast
Stop
Start

59
60
69
61
62

Reset
Reverse
Run
Slow
Start

18
19
20
21
22

Stop
Stop (red)
Test
Trip
Up

23
28
24
29
25

Legend
Auto
Close
Down
Emergency
Stop
Emergency
Stop (red)

Options
• Laser engraving on legend plates
• Legend plates available in white, red and aluminum in addition to standard black
• Round, yellow legend plates.

234
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7A–7

15599 Sec.7 12/9/01 11:14 AM Page 235

FS Control3 Dimensions

7/32 DIA.
MTG.
HOLES

4 7/8
4 5/16
C

6 1/16
5 1/2

B

C
F

B

.201 DIA.

K

MTG. HOLES

K

G
A

G

A

6 1/8
6 7/16

J

5
5 5/16

J

STAINLESS STEEL & CARBON STEEL

F

FIBERGLASS

Dimensions Stainless Steel (X2SS) & Carbon Steel (X2CS)
Body
Style

Outside
Dimensions

Mounting
Dimensions

1/2" Hubs

3/4" Hubs

1" Hubs

A

B

C

F

G

J

K

J

K

J

K

1 Hole

4 5/16

4 5/16

5

3 1/8

4 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

2 Holes

6 5/16

4 5/16

5

3 1/8

6 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

3 Holes

8 5/16

4 5/16

5

3 1/8

8 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

4 Holes

10 5/16

4 5/16

5

3 1/8

10 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

Dimensions Fiberglass (X2FG)
Body
Style

Outside
Dimensions

Mounting
Dimensions

1/2" Hubs

3/4" Hubs

1" Hubs

A

B

C

F

G

J

K

J

K

J

K

1 Hole

6 5/8

3 13/16

3 7/8

2 15/16

4 7/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

2 Holes

6 5/8

3 13/16

3 7/8

2 15/16

4 7/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

3 Holes

8 7/8

3 13/16

3 7/8

2 15/16

7 1/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

4 Holes

11 1/8

3 13/16

3 7/8

2 15/16

9 3/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

235
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 236

7A–8

FS Control3 Catalog Logic

Catalog Logic/Example

Enclosure Type

Cover
Holes Entry Hub Size

Industrial
Industrial Pilot
Pilot Devices
Devies

TOP

BOTTOM

X2CS - Carbon Steel
X2SS - Stainless Steel
X2FG - Fiberglass
1234-

1 Hole
2 Holes
3 Holes
4 Holes

T - Top Feed
B - Bottom Feed
F - Feed Through

Order pilot devices utilizing the suffix number from
the tables on pages 7A–2 to 7A–5. (Also, remember
to select legend plates from page 7A–6.)

2 - 1/2" Hub
3 - 3/4" Hub
4 - 1" Hub

The above example is a carbon steel control station, 4 holes, with feed through and 1/2" hub.
Hubs included.

236
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7B–1

15599 Sec.7 12/9/01 11:14 AM Page 237

PriStar Specifications
Features and Benefits
• Lightweight, corrosion-resistant, copper-free aluminum alloy (0.3% max. copper content).
• All operating shafts are stainless steel for corrosion resistance.
• Durable cast on lugs cannot get lost.
• Ground screw is highly visible and accessible.
• Uniform wall thickness (not ribbed) for versatility of conduit openings assuring 5 full threads
engagement and maximum available area for conduit drilling and tapping.
• Operators may be mounted through back wall for panel mounting.
• Box depth provides for the stacking of 2 contact blocks.
• Anodized aluminum operators install easily in the field.

Certifications/Compliances
E53505
LISTED

Certified LR36172

*

*CSA certified products require
guarded pilot devices.
Class I, Groups C&D
Class II, Groups E, F, G
Class III
For NEMA 4 or special machining
options, see XIFC Series in Section 5.

Table A2 Control Station Boxes
Number of
Operators

Surface
Mount

Panel
Mount

Std. Cond.
Size (inches)

1
2
3
4
5
6
7
8
12
15
18

X1
X2
X3
X4
X5
X6
X7
X8
X12
X15
X18

X1P
X2P
X3P
X4P
X5P
X6P
X7P
X8P
X12P
X15P
X18P

3/4
3/4
3/4

1
1 1/4
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2

Applicable Standard
Underwriters Laboratories: UL 698,
CSA C22.2 No. 30.

Surface Mount: Operators mounted in cover
Panel Mount: Operators mounted in back
Note: All operator holes are 3/4"-14 NPSM

Table B2 Pilot Lights & Lighted Pushbutton

Lens Color
Amber
Blue
Clear
Green
Red
White

Suffix Nos. for
Std. Pilot Lt.
Candelabra Base
1000 Hr. Lamp
60
61
62
63
64
65

Suffix Nos. for
Guarded Pilot Lt.
Candelabra Base
337
338
339
340
341
342

Suffix Nos. for
Pilot Lt.
Slide Base
5000 Hr. Lamp
66
67
68
69
70
71

Suffix Nos. for
Guarded Pilot Lt.
Slide Base

Suffix Nos. for
Lighted Pushbutton

343
344
345
346
347
348

30
35
40
45
50
55

237
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 238

7B–2

PriStar Box & Suffix Numbers

Table C2 Selector & Key Switch Suffix Numbers
Selector Switch Suffix Numbers
Contact
Block/Cam
Included

Contact
Sequence

Standard
Sel. Switch

Sel. Switch
w/ Padlock

Spring Ret.
Center
from R & L

Key Switch Suffix Numbers

Spring Ret.
Center
from R

Spring Ret.
Center
from L

Standard
Key Switch

Spring Ret.
Center
from R & L

Spring Ret.
Center
from R

Spring Ret.
Center
from L

BT1A/1

NO
NC

XO
OX

6

283

82

BT1B/1

NC
NO

OX
XO

7

284

83

BT2/1

NO
NO

OX
OX

8

285

84

BT3/1

NC
NC

XO
XO

9

286

85

BT2/3

NO
NO

XOO
OOX

10

293

111

135

159

86

229

249

269

BT1B/2

NC
NO

XOX
XXO

11

288

112

136

160

87

224

244

264

BT2/2

NO
NO

XOX
OOX

12

289

113

137

161

88

225

245

265

BT3/2

NC
NC

OXO
XXO

13

290

114

138

162

89

226

246

266

BT3/3

NC
NC

OXX
XXO

14

294

115

139

163

90

230

250

270

BT1A/2

NO
NC

OXO
OOX

15

287

116

140

164

91

223

243

263

BT1A/3

NO
NC

OXX
OOX

16

291

117

141

165

92

227

247

267

BT1B/3

NC
NO

XOO
XXO

17

292

118

142

166

93

228

248

268

Contact blocks and cam included with selector switch.

O = Contact Open
X = Contact Closed

Table D2 Pushbutton Suffix Numbers

BT1A
BT2
BT3
BT4
BT5

Contact
Configuration

Momentary
Pushbutton

Momentary
Pushbutton
w/ Padlock

1NO/1NC
2NO
2NC
1NO
1NC

1
2
3
4
5

307
308
309
310
311

Mushroom Head
Momentary
Pushbutton
106
107
108
109
110

1

Dual Pushbutton
Momentary
72
73
74

2

Dual Pushbutton
w/ Lockout
322
323
324

2

Dual Pushbutton
Maint.
77
78
79

2

Dual Pushbutton
Maint. w/ Lock

2

327
329
329

Pushbuttons furnished with Black collars and knobs as standard.
Optional knobs: Green, Red. Optional Collars: Blue, Green, Gold,
Red or Aluminum (unpainted).
1 Standard knob is Red. Black or Green available.
2 Standard with one Green knob labeled “Start” and one Red
knob labeled “Stop.” Unlabeled Black knobs available.

Other pilot devices available – Consult Factory.

238
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7B–3

15599 Sec.7 12/9/01 11:14 AM Page 239

PriStar Dimensions

4 1/2"
4 5/16"

BT

3 1/4"

1"
A

B

1 1/2"

Dimensions

Enclosure
X1
X2
X3
X4
X5
X6
X7
X8
X12
X15
X18

Nom. Inside
Dim.
030303
030603
030703
030903
031103
031303
031503
031803
032403
033003
033603

Dim. in Inches
B
A
4 1/2
7
8
10
12
14
16
19
25
31
37

5 1/2
8
9
11
13
15
17
20
26
32
38

Est. Weight
(lbs.)
5
7
8
10
11
12
13
16
21
28
33

*Std. Conduit
Size (inches)
3/4
3/4
3/4

1
1 1/4
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2

Control Stations have conduit openings centered on top and bottom.
*Consult factory for other conduit sizes.

239
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 240

7B–4

PriStar Ordering Information

To Order
To order control stations, determine the number of
operators required. Select the control station box by
operator quantity and mounting type from Table A2.
Order operators by suffix numbers from Tables B2, C2
and D2. Add suffix numbers to box number and separate

by dashes. All operator holes must be filled by an
operator. Use suffix “0” for plugs to fill unused space.
Installation of operators will be made from top to bottom
in sequence as listed. Select optional legend plates from
Table F2 below.

Table F2 Legend Plate Standard Markings
Pushbuttons/Pilot Lights
Blank
Start
Inch
Stop
Run
Forward
Reverse
Fast

Slow
Open
Close
Up
Jog
On
Off
Back

Selector Switches
Reset
In
Out
Left
Right
Low
High
Down
E-Stop

Run-Jog
Hand-Auto
Forward-Reverse
Fast-Slow
Open-Close
Up-Down
Off-On

Open-Off-Close
Fast-Off-Slow
Run-Auto-Jog
Hand-Off-Auto
Forward-Off-Reverse
1-Off-2
Up-Off-Down

Legend plates are anodized
aluminum with engraved letters on
black background.
Stop has red and start has green
background.
Special engraved legend plates can
be supplied.

Contact Ratings PriStar
AC
Volts
Make & Interrupting Capacity A
Normal Load Break
A
Continuous Current
A

110
60
6.0
10

DC

220
30
3.0
10

440
15
1.5
10

550
12
1.2
10

120
1.1
1.1
10

240
0.5
0.5
10

600
0.2
0.2
10

240
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7C–1

15599 Sec.7 12/9/01 11:14 AM Page 241

Factory-Sealed Control Stations
F

B E

C

D
A

Dimensions
Dimensions in Inches
XFSA3223

XFSA3911

XFSA3185
A
4 1/4

Features and Benefits
• Factory-sealed control stations eliminate the need for poured seals
• All control stations have 3/4" feed-through conduit entries
• Factory-sealed contact block rated NEMA A600 and NEMA Q300
• All selector switches have lock-out capabilities
• Bodies and covers are cast from lightweight, corrosion-resistant,
copper-free aluminum
• High-quality legend plates permit easy identification of device function
• Durable cast-on lugs cannot get lost

B
8

C
4 11/16

D
2 5/8

E
7 1/8

F
11/32

Certifications/Compliances
Cover Assembly
Body Assembly
Complete Enclosure Assembly
Class I, Division 1, Groups B* CD
Class I, Division 2, Groups BCD†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB
NEMA 4 Option:
Class I, Division 1, Groups C & D
Class I, Division 2, Groups BCD†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB

• Ground screw is highly visible and accessible
• Strong, durable materials for reliability and safety
• Customization of box entries available – please consult factory
• NEMA 4 option available – please consult factory

Class II, Division 1, Groups E, F & G
Class II, Division 2, Groups E, F & G†

Material/Finish

NEMA 3, 3R, 4, 7CD, 9EFG, 12

Body, Cover: Copper-Free Aluminum
Operator and Pilot Light Bodies: Anodized Aluminum
Operator Shaft: Stainless Steel
Levers: Aluminum

Contact BlockOnly
Class I, Division 1, Groups BCD (recognized)
Class I, Division 2, Groups BCD (listed)
Class I, Zone 1, Group IIB+H2
Class I, Zone 2, Group IIB+H2

Application
A wide variety of control stations may be assembled from Adalet bodies,
devices and covers for use indoor or outdoor where Class I or Class II hazards
are present, such as petroleum refineries, chemical plants and grainprocessing and storage facilities. XFS Control Stations may be used in
conjunction with magnetic starters or contactors for remote control of motors.

Applicable Standard
Underwriters Laboratories:
UL 698, UL 1203
*Group B pending
†Division 2 Compliance

Catalog No.

Control Station Description

XFSA3101

Black momentary pushbutton

XFSA3223

Start-stop momentary pushbuttons

XFSA3911

Maintained emergency stop with mushroom head

XFSA3173

2-position, 2-circuit selector switch with 1NO/1NC contact

XFSA3185

2-position, 4-circuit selector switch with 2NO/2NC contacts

XFSA3178

3-position, 2-circuit selector switch with 1NO/1NC
contact marked HAND-OFF-AUTO

XFSA31208

Green pilot light

XFSA31209

Red pilot light

XFSA32089

One green and one red pilot light

XFSA30925

Red pilot light with start-stop momentary dual pushbutton

241
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 242

7C–2

OmniStar Specifications

Features and Benefits
• Factory sealed control station eliminates the need for poured seals
• Factory sealed contact block rated NEMA A600 and NEMA Q300
• Single-station through four-gang vertical or horizontal configurations are available to
accommodate a wide variety of system needs
• Conduit entries available in 1/2", 3/4" and 1" sizes either dead-end or feed through
• Customization possible by using any of a wide variety of devices: pilot lights, miniature
operators, momentary contact pushbuttons, selector switches, key operator selector
switches or rocker arm
• One- through four-hole covers allow up to four NO/NC contact blocks per station
• Bodies and covers are cast from lightweight, corrosion-resistant, copper-free aluminum
• High-quality legend plates permit easy identification of device function
• Durable cast-on lugs cannot get lost
• Ground screw is highly visible and accessible
• Strong, durable materials for reliability and safety
• Customization of box entries available – please consult factory
• NEMA 4 option available – please consult factory

Material/Finish
Body, Cover: Copper-Free Aluminum
Operator and Pilot Light Bodies: Anodized Aluminum
Operator Shaft: Stainless Steel
Knobs: Nylon

Application
A wide variety of control stations may be assembled from Adalet bodies, devices and
covers for use indoor or outdoor where Class I or Class II hazards are present, such as
petroleum refineries, chemical plants and grain processing and storage facilities. XFS
Control Stations may be used in conjunction with magnetic starters or contactors for
remote control of motors.

Certifications/Compliances
XFSC Cover Assembly
XFSB Body Assembly
LISTED
XFSA Complete Enclosure Assembly
Class I, Division 1, Groups CD
Class I, Division 2, Groups B*CD†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB
NEMA 4 Option:
Class I, Division 1, Groups C & D
Class I, Division 2, Groups C & D†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB
Class II, Division 1, Groups E, F & G
Class II, Division 2, Groups E, F & G†
NEMA 3, 3R, 4, 7CD, 9EFG, 12

Contact Block
Only

LISTED

Class I, Division 1, Groups BCD (recognized)
Class I, Division 2, Groups BCD (listed)
Class I, Zone 1, Group IIB+H2
Class I, Zone 2, Group IIB+H2

Applicable Standard
Underwriters Laboratories: UL 698, UL 1203

*Group B Compliance
†Division 2 Compliance

242
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7C–3

15599 Sec.7 12/9/01 11:14 AM Page 243

OmniStar Bodies & Covers

Table A1 Conduit Entry
A

Hole Location Suffix Numbers
Conduit
Entry

Catalog Suffix No.

Top

Bottom

Left

1/2"
3/4"
1"

2
3
4

A
A
A

B
B
B

C
1
C
C

1

Replacement Body
Catalog No.

Right
1

D
1
D
D

C

XFSB2
XFSB3
XFSB4

D

B

1 Catalog suffix number followed by hole location suffix (C&D holes always 1" NPT)
Example – 3ACD would be a body with a 3/4" hole in the top position and two 1" holes on the sides.
Note: When ordering assembled control station, catalog number should begin with XFSA to indicate body
and cover. Refer to page 7D–6 for catalog logic/example.

Table B1 Covers
Style

Catalog Suffix No.

NEMA Type 4
Catalog Suffix No.

Replacement Cover
2
Catalog No.

NEMA Type 4
Replacement Cover
2
Catalog No.

–
1
2
3
4
5
RA

-N4
1-N4
2-N4
3-N4
4-N4
5-N4
RA-N4

XFSC
XFSC-1
XFSC-2
XFSC-3
XFSC-4
XFSC-5

XFSC-N4
XFSC-1-N4
XFSC-2-N4
XFSC-3-N4
XFSC-4-N4
XFSC-5-N4

Blank
One 3/4" NPSM Hole
Two 3/4" NPSM Holes
One 3/4" NPSM Hole and Two 3/8-16” UNC Holes
Four 3/8-16" UNC Holes
Two 3/8-16" UNC Holes
Rocker Arm — See next page

2 Replacement cover catalog numbers should be followed by suffix numbers for Adalet operators.
Example – XFSC-4-N4 would be a NEMA Type 4 cover with four holes.

XFSC-1

XFSC-2

XFSC-4

XFSC-3

XFSC-5

243
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 244

7C–4

OmniStar Device Kits – Pushbuttons & Pilot Lights

Table C1 Pushbuttons
Catalog
Suffix Nos.
for 1 NO/1 NC

Kit
Momentary Pushbutton – Black
Momentary Pushbutton – Green
Momentary Pushbutton – Red
Momentary PB w/ Padlock – Black
Momentary PB w/ Padlock – Green
Momentary PB w/ Padlock – Red
Mushrm Hd Momentary PB – Black
Mushrm Hd Momentary PB – Green
Mushrm Hd Momentary PB – Red
Mushrm Hd Maintained
Mushrm Hd Maintained
Lighted Pushbutton – Amber2
Lighted Pushbutton – Blue2
Lighted Pushbutton – Clear2
Lighted Pushbutton – Red2
Lighted Pushbutton – White2
Dual PB Momentary – “Start/Stop”
Dual PB Momentary – Green/Red
Dual PB Momentary – Black/Black
Dual PB w/ Lockout – “Start/Stop”
Dual PB w/ Lockout – Green/Red
Dual PB w/ Lockout – Black/Black
Dual PB Maint – “Start/Stop”
Dual PB Maint – Green/Red
Dual PB Maint – Black/Black
Dual PB Maint w/ Lockout – “Start/Stop”
Dual PB Maint w/ Lockout – Green/Red
Dual PB Maint w/ Lockout – Black/Black
Rocker Arm 2 NO/2 NC1

Use Suffix “0” for 3/4" NPSM plug and Suffix “00” for 3/8" UNC
plug to fill unused spaces. For collars different in color than
pushbutton ordered, consult factory.

Catalog
Suffix Nos.
for 2 NO/2 NC

1F
2F
3F
4F
5F
6F
7F
8F
9F
911F

10F
11F
12F
13F
14F
15F
16F
17F
18F
912F

1F

9F

25F
26F
27F
28F
29F
30F
31F
32F
34F
35F
36F
37F
RA1

23F

25F

20F
21F
22F
23F
24F

1 For Rocker Arm 3 NO/3 NC, use suffix RA2 andfor Rocker Arm 4 NO/4 NC, use suffix RA3.
2 Not for use in NEMA 4 applications

61F

Contact Ratings OmniStar
AC
Volts
Make & Interrupting Capacity
Normal Load Break
Continuous Current
Catalog No.

FSBT

A
A
A

110
60
6
10

220
30
3
10

DC
440
15
1.5
10

550
12
1.2
10

120
.55
.55
2.50

440
.27
.27
2.50

One Normally Open and One Normally Closed.

Table D1 Pilot Lights

Lens Color

Suffix Nos. for
Guarded Pilot Lt.
Candelabra Base

Suffix Nos. for
Guarded Pilot Lt.
Slide Base

Suffix Nos. for
Miniature Pilot
Lights

Amber
Blue
Clear
Green
Red
White

205F
206F
207F
208F
209F
210F

215F
216F
217F
218F
219F
220F

201F

202F
203F

244
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7C–5

15599 Sec.7 12/9/01 11:14 AM Page 245

OmniStar Device Kits – Selector Switches
Table E1 Selector Switches

Selector Switch

Cam

Suffix Nos. for
Mounting Position A
1 NO/1 NC

1
2
3
4
5
6
1
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
1
2
3
4
5
6

51F
52F
53F
54F
55F
56F
73F
74F
75F
76F
77F
78F
91F
92F
93F
94F
95F
106F
107F
108F
109F
110F
122F
123F
124F
125F
126F
138F
139F
140F
141F
142F
153F
154F
155F
156F
157F
168F
169F
170F
171F
172F
183F
184F
185F
186F
187F
188F

Selector Switch
Selector Switch
Selector Switch
Selector Switch
Selector Switch
Selector Switch
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch
Key Selector Switch
Key Selector Switch
Key Selector Switch
Key Selector Switch
Key Selector Switch

Suffix Nos. for
Suffix Nos. for
Mounting Position B Mounting Position AB
1 NO/1 NC
2 NO/2 NC
61F
62F
63F
64F
65F
66F
79F
80F
81F
82F
83F
84F
96F
97F
98F
99F
100F
111F
112F
113F
114F
115F
127F
128F
129F
130F
131F
143F
144F
145F
146F
147F
158F
159F
160F
161F
162F
173F
174F
175F
176F
177F
189F
190F
191F
192F
193F
194F

MOUNTING
POSITION A

Contact Sequence Chart
2-Position
Selector
Switches
Cam 1
Contact
Sequence

O = Contact Open
X = Contact Closed
Circuit of Contact Block

67F
68F
69F
70F
71F
72F
85F
86F
87F
88F
89F
90F
101F
102F
103F
104F
105F
116F
117F
118F
119F
120F
132F
133F
134F
135F
136F
148F
149F
150F
151F
152F
163F
164F
165F
166F
167F
178F
179F
180F
181F
182F
195F
196F
197F
198F
199F
200F

3-Position Selector Switches
Cam 2
Cam 3
Cam 4
Contact
Contact
Contact
Sequence Sequence Sequence

Cam 5
Cam 6
Contact
Contact
Sequence Sequence

Mounting
Position

Normally Closed (NC)
Normally Open (NO)

A

Normally Closed (NC)
Normally Open (NO)

B

Circuit A
Circuit B

XO
OX

XX O
OO X

X XO
OOX

XOX
OXO

OOX
X XO

OOX
OXO

Circuit A
Circuit B

XO
OX

OX O
XO X

OXX
X OO

XOO
OX X

OXX
X OO

XOO
OOX

MOUNTING
POSITION B

VIEWED
FROM BACK

POSITIONS A AND B TO BE
DETERMINED AT INSTALLATION

245
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:15 AM Page 246

7C–6

OmniStar Dimensions – Vertical & Horizontal 4-Gang Assembly

L
K
J

R
B

E

Q

F
D
A

F

P
C

B

E

HORIZONTAL 4-GANG ASSEMBLY

C

D
A

VERTICAL 4-GANG ASSEMBLY

Dimensions
Dimensions in Inches

A
4 1/4

B
8

4

C

D

E

F

J

K

11/16

2 5/8

7 1/8

11/32

7 5/16

14 5/8

L
21

15/16

P
9 1/8

Q

R

18 1/4

27 3/8

246
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

7C–7

15599 Sec.7 12/9/01 11:15 AM Page 247

OmniStar Ordering Information

To Order
To order control stations, determine the number of
operators required. Select the control station body and
cover by operator quantity and mounting type from Tables
A1 and B1. Order operators by suffix numbers from
Tables C1, D1 and E1. Add suffix numbers to box/cover
assembly number (replacing the “B” in the box catalog
number with an “A” for “Assembly” followed by a

number to indicate the number of holes in the cover),
separating the assembly number from the suffix
number(s) by dashes. All operator holes must be filled by
an operator or plug. Installation of operators will be made
in the following order: upper left, upper right, lower left,
lower right. See Assembly Catalog Numbers Logic/Example
below. Select legend plates from Table F1 below.

Table F1 Legend Plate Standard Markings
Pushbuttons/Pilot Lights
Blank
Start
Inch
Stop
Run
Forward
Reverse
Fast

Slow
Open
Close
Up
Jog
On
Off
Back

Selector Switches
Reset
In
Out
Left
Right
Low
High
Down
E-Stop

Run-Jog
Hand-Auto
Forward-Reverse
Fast-Slow
Open-Close
Up-Down
Off-On

Open-Off-Close
Fast-Off-Slow
Run-Auto-Jog
Hand-Off-Auto
Forward-Off-Reverse
1-Off-2
Up-Off-Down

Legend Plates are anodized
aluminum with engraved letters on
black background.
Stop has red and start has green
background.
Special engraved legend plates can
be supplied.

Assembly Catalog Numbers Logic/Example

X

F

S

BOX AND COVER
ASSEMBLY

A

2
3
4

A
B
C
D

CONDUIT HOLE SIZE
*HOLE LOCATIONS
IN BOX

1
2
3
4
5
RA

–
SUFFIX NUMBERS
(FILLING HOLES UPPER LEFT,
UPPER RIGHT, LOWER LEFT,
LOWER RIGHT)

XFSA2A1-1F is an
assembled control
station with one 1/2"
hub, and one operator
hole with one
momentary pushbutton
black.

COVER

*C & D holes are always supplied as 1" NPT

247
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:15 AM Page 248

Quick Reference Guide
METHODS OF PROTECTION
Area
Division 1

Division 2

Area
Zone 0
Zone 1

Zone 2

Protection Method

UL

CSA

CENELEC

Explosionproof
Intrinsically Safe
(2 Fault)
Purge/Pressurized
(Type X or Y)
Nonincendive
Non-sparking device
Purge/Pressurized
(Type Z)
Hermetically sealed
Any Class I,
Division 1 Method
Protection Method
Intrinsically Safe 'ia'
(2 Fault)
Flameproof 'd'
Increased Safety 'e'
Intrinsically Safe 'ib'
(1 Fault)0
Encapsulation 'm'
Oil Immersion 'o'
Purged/Pressurized 'p'
Powder filling 'q'
Any Zone 0 Method
Non-sparking 'nA'
Hermetically sealed 'nC'
Nonincendive 'nC'
Restricted breathing 'nR'
Any Zone 0 or 1 Method

ANSI/UL 1203

CSA-30

--

--

ANSI/UL 913

CSA-157

--

--

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604
UL 1604

CSA-213
CSA-213

---

---

ANSI/NFPA 496

ANSI/NFPA 496

--

--

UL 1604

CSA-213

--

--

--

--

--

--

UL (AEx)

CSA (Ex)

CENELEC (EEx)

IEC (Ex)

UL 2279 Pt. 11

CSA-E79-18

EN 50028

IEC 60 079-18

UL 2279 Pt. 1
UL 2279 Pt. 7

CSA-E79-1
CSA-E79-7

EN 50018
EN 50019

IEC 60 079-1
IEC 60 079-7

UL 2279 Pt. 11

CSA-E79-11

EN 50020

IEC 60 079-11

UL 2279 Pt. 18
UL 2279
UL 2279 Pt. 2
UL 2279
-UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
UL 2279 Pt. 15
--

CSA-E79-18
CSA-E79-6
CSA-E79-2
CSA-E79-5
-CSA-E79-15
CSA-E79-15
CSA-E79-15
CSA-E79-15
--

EN 50028
EN 50015
EN 50016
EN 50017
-prEN 50021
prEN 50021
prEN 50021
prEN 50021
--

IEC 60 079-18
IEC 60 079-6
IEC 60 079-2
IEC 60 079-5
-IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
IEC 60 079-15
--

TEMPERATURE CLASSES

AREA CLASSIFICATIONS
Ignitable Materials
Present Continuously

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Zone 0
(Zone 20 Dust)
Zone 0
Division 1

Zone 1
(Zone 21 Dust)
Zone 1
Division 1

Zone 2
(Zone 22 Dust)
Zone 2
Division 2

IEC/CENELEC
NEC 505
NEC 500

ATEX Classification by Group & Category According to Use
Ignitable Materials
Present Continuously
Equipment Group II Category 1 Equipment
(surface)
Equipment Group I
Category M1 Equipment
(mining)

IEC

Ignitable Materials
Present Intermittently

Ignitable Materials
Present Abnormally

Category 2 Equipment

Category 3 Equipment

Category M2 Equipment

—

GAS GROUPINGS
Gas, Dust or Fiber

NEC 505/IEC/CENELEC

NEC 500

Acetylene
Hydrogen
Ethylene
Propane
Methane
Metal Dust
Coal Dust
Grain Dust
Fibers

Group IIC
Group IIC/Group IIB+H2
Group IIB
Group IIA
Group I (firedamp)
None
None
None
None

Class I/Group A
Class I/Group B
Class I/Group C
Class I/Group D
Class I/Group D
Class II/Group E
Class II/Group F
Class II/Group G
Class III

ACRONYMS
CENELEC - European Committee for Electrotechnical Standardization
IEC - International Electrotechnical Commission
NEC - National Electrical Code
U.L. - Underwriters Laboratories
C.S.A. - Canadian Standards Association
FM - Factory Mutual
BASEEFA - British Approvals Service for Electrical Apparatus in
Flammable Atmospheres
NFPA - National Fire Protection Agency
ISO - International Organization for Standardization
ANSI - American National Standard Institute
ATEX - Atmospheres Explosibles

Maximum
Surface
Temperature

NEC 505
IEC
CENELEC

450°C
300°C
280°C
260°C
230°C
215°C
200°C
180°C
165°C
160°C
135°C
120°C
100°C
85°C

T1
T2

T3

T4
T5
T6

NEC 500
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

INGRESS PROTECTION (IP XX) CODES
#

First Number
(Protection against Solid Bodies)

Second Number
(Protection against Liquids)

0
1
2
3
4
5
6
7
8

No protection
Objects greater than 50mm
Objects greater than 12mm
Objects greater than 2.5mm
Object greater than 1mm
Dust Protected
Dust-tight
---

No protection
Vertically dripping water
75-90 Deg. dripping water
Sprayed water
Splashed water
Water jets
Heavy seas
Effects of immersion
Indefinite immersion

15599 Sec.8 12/9/01 11:17 AM Page 249

Circuit Breaker Lighting & Power Distribution Panel Boards
Explosionproof and Dust-Ignitionproof

8A–1

ENCLOSURES: The housings are copper-free cast aluminum
alloy. The housings are Adalet XCE series and have precision
ground cover and body joints.
The design offers sufficient gutter space on sides to allow
through wiring and easy lug connection. All enclosures are
furnished with hinges, stainless steel cover bolts and are
provided with Nema 4 gasketing. All covers are removable for
clear access to breakers and gutter space. The compact design
of rectangular housings permits close grouping on switch racks
and other structures. No additional space is required for cover
removal except from the front.
MECHANICAL FEATURES: The front mounted power panel
and lighting panel branch breaker handles can be padlocked
either in “off” or “on” position. All breaker handles are spring
loaded allowing closing of the cover with breaker toggle in any
position. Operating handle shafts have “V” ring gaskets for
watertight application.
ELECTRICAL FEATURES: Breaker panel chassis, featuring
bolt-on circuit breakers, are made by Cutler-Hammer. Chassis for
the power distribution XPB2 series provides 480V/277 volt
connections. The circuit breakers are rated for 480 volt max.
The Adalet lighting panel board XPB1 series offers 15 through
60 amps, 120, 240 volt bolt on circuit breakers with ground and
insulated neutral bars as standard features. The Cutler-Hammer
Industrial Ground Fault Circuit Protectors (GFCI 5mA, GFEPD
30mA) and switching neutral breakers are available as optional
features.

Compliances:

Approvals:

UL, cUL Classified Enclosure
UL Standard 1203
CSA Standard C22.2 No. 30

Enclosure Certifications

Class I, Groups B, C, D
Class II, Groups E, F, G
Class III
NEMA 4, 7, 9

E81696

249
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 250

Circuit Breaker Lighting Panel Boards
Explosionproof and Dust-Ignitionproof
CLASS I, GROUP B, C, D; CLASS II, GROUPS E, F & G;
CLASS III, NEMA 4, 7 & 9
8A–2

Explosionproof circuit breaker lighting panelboards use cast aluminum alloy housings with hinged cover. External operating handles
can be padlocked in “on” or “off” position. Incorporates Cutler-Hammer bolt-on breakers @ 240 volt max. Top feed standard.

BACK FED MAIN BREAKER PANELBOARDS
120/240 VOLT, 1 PHASE 3 WIRE, SOLID NEUTRAL
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM.)
Number of
Avail. Breakers

MLO / BFD

Catalog
Number

Main Breaker
Amperes

Box
Size

10

BFD

XPB1-121 B1

100

A

16

BFD

XPB1-181 B1

100

A

22

BFD

XPB1-241 B1

100

B

BACK FED MAIN BREAKER PANELBOARDS
120/208 VOLT, 3 PHASE 4 WIRE, SOLID NEUTRAL
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM.)
Number of
Avail. Breakers

Catalog
Number

MLO / BFD

Main Breaker
Amperes

Box
Size

9

BFD

XPB1-123 B1

100

A

15

BFD

XPB1-183 B1

100

A

21

BFD

XPB1-243 B1

100

B

250
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 251

Circuit Breaker Lighting Panel Boards
Explosionproof and Dust-Ignitionproof

8A–3

MAIN LUG ONLY PANELBOARDS
1 PHASE 3 WIRE 120/240 VOLT TOP FEED MAIN LUG ONLY
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM)
Number of
Breakers

Catalog
Number

Main Lug
Amperes

Box
Size

12

XPB1-121L1

100

A

18

XPB1-181L1

100

A

24

XPB1-241L1

100

B

24

XPB1-241L2

225

B

30

XPB1-301L2

225

D

36

XPB1-361L2

225

D

MAIN LUG ONLY PANELBOARDS
3 PHASE 4 WIRE 120/208 VOLT TOP FEED MAIN LUG ONLY
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM)
Number of
Breakers

Catalog
Number

Main Lug
Amperes

Box
Size

12

XPB1-123L1

100

A

18

XPB1-183L1

100

A

24

XPB1-243L1

100

B

24

XPB1-243L2

225

B

30

XPB1-303L2

225

D

36

XPB1-363L2

225

D

How to order:
A) Specify catalog number and voltage
B) Number of operator handles, single pole, two pole and
three pole as required.
C) Circuit breakers, number of poles and ampere rating.
Unused spaces will be plugged. Top feed standard.

251
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 252

Circuit Breaker Lighting Panel Boards
Explosionproof and Dust-Ignitionproof
MODIFICATIONS AND OPTIONS
8A–4

Branch Breakers – Operating Handles – Components
CIRCUIT BREAKER OPERATOR HANDLES INSTALLED IN XPB1 PANEL BOARDS
Catalog
Number

Weight
Each

Description

XPB1-H1

For single pole BAB breakers

1/4 lb.

XPB1-H2

For two pole BAB breakers

1/4 lb.

XPB1-H3

For three pole BAB breakers

1/4 lb.

XPB1-GL

For single pole GFI ground

1/4 lb.

XPB1-GR

Fault breakers (specify left or right side)

1/4 lb.

BRANCH CIRCUIT BREAKERS INSTALLED IN XPB1 PANEL BOARDS:
BOLT-ON THERMAL MAGNETIC BREAKERS 120/240 VOLT 10,000 AMPERE I.C.
Catalog No.

Description

XPB1-1*

1 pole breaker (available in 10-70 amp)

XPB1-2*

2 pole breaker (available in 10-100 amp)

XPB1-3*

3 pole breaker (available in 10-100 amp)

*Add ampere rating of the branch breaker when ordering.
GROUND FAULT CIRCUIT PROTECTORS
120/240 VOLT 10,000 AMPERE I.C. STD.
22,000 AMPERE I.C. OPTIONAL

BOLT-ON SWITCHING NEUTRAL BREAKERS
120/240 VOLT 10,000 AMPERE I.C.

Catalog No.

Description

Catalog No.

Description

XPB1-1GFCI*

1 pole GFCI Breaker 5 MA Sensitivity

XPB1-N1*

1 pole switching to neutral
Requires two spaces (available in 15-30 amp)
2 pole switching to neutral
Requires three spaces (available in 15-30 amp)

XPB1-2GFCI*

2 pole GFCI Breaker 5 MA Sensitivity

XPB1-1GFEPD*

1 pole GFCI Breaker 30 MA Sensitivity

XPB1-2GFEPD*

2 pole GFCI Breaker 30 MA Sensitivity

XPB1-N2*

*Add ampere rating of the branch breaker when ordering

Above Available with special application Bell Alarm or Auxiliary Switch.

*Add ampere rating of the branch breaker when ordering

OPTIONAL FEATURES
MODIFICATIONS:
Suffix
Letter
E
EE
L1
L2
NP
CU
Q

Description
Breather Drain (not type 4)
Breather and drain (not type 4)
Epoxy Coating Outside
Epoxy Coating Inside/Outside
Lamacoid Nameplate
Copper Bus Bar
Quad-Lead Bolts

252
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 253

Circuit Breaker Power Distribution Panel Boards
Explosionproof and Dust-Ignitionproof

Explosionproof circuit breaker power panelboards use cast aluminum alloy housings with hinged cover. External operating handles
can be padlocked in “on” or “off” positions. Incorporates Cutler-Hammer bolt-on breakers @ 480 volt max. Top feed standard.

BACK FED MAIN BREAKER PANELBOARDS
277/480 VOLT, 3 PHASE 4 WIRE, SOLID NEUTRAL
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
14,000 AMPERE INTERRUPTING CAPACITY (SYM.)
Number of
Avail. Breakers

MLO / BFD

Catalog
Number

Main Breaker
Amperes

Box
Size

9

BFD

XPB2-123B1

100

A

15

BFD

XPB2-183B1

100

A

21

BFD

XPB2-243B1

100

B

100 ampere main lugs conductor size #12 -1/0 CU/AL.
225 ampere main lugs conductor size #6-300 MCM CU/AL.
How to order:
A) Specify catalog number and voltage
B) Number of operator handles, single pole, two pole and three pole as
required.
C) Circuit breakers, number of poles and ampere rating
Unused spaces will be plugged. Top feed standard.

MAIN LUG ONLY PANELBOARDS
277/480 VOLT, 3 PHASE 4 WIRE
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
14,000 AMPERES INTERRUPTING CAPACITY (SYM)

Compliances:
UL, cUL Classified Enclosure
UL Standard 1203
CSA Standard C22.2 No. 30
Class I, Groups B, C, D
Class II, Groups E, F, G
NEMA 4, 7, 9

Number of
Breakers

Catalog
Number

Main Lug
Amperes

Box
Size

12

XPB2-123L1

100

A

18

XPB2-183L1

100

A

24

XPB2-243L1

100

B

24

XPB2-243L2

225

B

Approvals:

30

XPB2-303L2

225

D

Enclosure Certifications

36

XPB2-363L2

225

D

How to order: Specify catalog number, operator handles and
circuit breakers as separate items. Single pole breakers use 1
handle space, 1 handle. 2 pole, 2 spaces, 1 handle. 3 pole, 3
spaces, 1 handle. Unused spaces will be plugged. Top feed
standard.

E81696

253
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

8A–5

CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; CLASS II, NEMA 4, 7 & 9

15599 Sec.8 12/9/01 11:17 AM Page 254

Circuit Breaker Power Distribution Panel Boards
Explosionproof and Dust-Ignitionproof
MODIFICATIONS AND OPTIONS
8A–6

Branch Breakers – Operating Handles – Components
BREAKER OPERATOR HANDLES INSTALLED IN XPB2 PANEL BOARDS
Catalog
Number
XPB2-H1

Description

Weight
Each

For 1, 2 or 3-pole GHB breaker

1/4 lb.

BRANCH CIRCUIT BREAKERS INSTALLED IN XPB2 PANEL BOARDS:
BOLT-ON THERMAL MAGNETIC BREAKERS
Catalog No.
XPB2-1*

Description
1 pole GHB breaker (available in 15-100 amp)
277 volt A.C.
2 pole GHB breaker (available in 15-100 amp)
480 volt A.C.
3 pole GHB breaker (available in 15-100 amp)
480 volt A.C.

XPB2-2*
XPB2-3*

*Add ampere rating of the branch breaker when ordering.

OPTIONAL FEATURES
MODIFICATIONS:
Suffix
Letter
E
EE
L1
L2
NP
CU
Q

Description
Breather Drain (not type 4)
Breather and drain (not type 4)
Epoxy Coating Outside
Epoxy Coating Inside/Outside
Lamacoid Nameplate
Copper Bus Bar
Quad-Lead Bolts

254
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 255

Circuit Breaker Lighting and Distribution Panel Boards
Explosionproof and Dust-Ignitionproof
ENCLOSURE DIMENSIONS & DATA SHEET

A

B

1/2" NPT

Top

(1)

—

(1)

—

Side

—

(2)

—

Bottom

(1)

(8)

—

—
—

Top

(1)

—

(1)

—

—

(2)

—

—

Bottom

(1)

(8)

—

—

Top

(1)

—

—

(1)

Side

—

(2)

—

—

Bottom

(1)

(10)

—

—
(1)

Top

(1)

—

—

Side

—

(2)

—

—

Bottom

(1)

(10)

—

—

D

(C) Overall
Width

3" NPT

Side

C

(B) Mtg
Height

Conduit Entries
1" NPT
2" NPT

Box
Size

Internal
Dimensions

(A) Mtg
Width

(D) Overall
Height

(E) Overall
Depth

A

161606

19 3/4

11

20 7/8

20 7/8

11

5/8

B

162406

19 3/4

18 3/8

20 7/8

28 7/8

11 1/2

5/8

C

162806

19 3/4

22 1/2

20 1/2

32 1/2

10 3/4

5/8

D

163406

19 3/4

27

20 1/2

38 1/2

10 3/4

5/8

8A–7

CONDUIT ENTRIES
Enclosure
Size

Mtg. Bolt
Size

Box Size

F

G

H

J

K

L

M

N

Weight lbs.

A

1 1/4

3 3/4

4 3/4

2 3/8

3 5/8

1

3 1/2

2 1/2

160

B

1 1/4

3 3/4

4 3/4

2 3/8

3 5/8

3

5

2 1/2

220

C

2

4

4 15/16

2 15/16

4 3/16

5

7

2 1/2

235

D

2

4

4 15/16

2 15/16

4 3/16

8

11

2 1/2

285

255
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 256

Motor Control Explosionproof Circuit Breakers - Disconnect Switches

8B–1

EXPLOSIONPROOF AND DUST-IGNITIONPROOF
CLASS I, GROUPS B, C & D: CLASS II, GROUPS E, F & G;
NEMA 7 & 9
BREAKERS: Circuit breakers are thermal magnetic type and
are available in frame sizes ranging from 15 to 1200
amperes. Also available as non-automatic circuit interrupters,
without automatic overload trip elements for load switching
and isolation. In this application short circuit and overload
protection must be provided by separate protection device.
Breakers also available for magnetic trip only.
The units can be set up for GE, Cutler-Hammer
(Westinghouse), Square-D and ITE (Siemens) brand circuit
breakers. Consult factory for other brands. Holes for CutlerHammer circuit breakers are drilled directly into back wall.
ENCLOSURES: The housings are copper-free cast
aluminum alloy. The enclosures are Adalet XCE series with
precision ground cover and body joints.
The enclosure design offers sufficient space for wire
bending and ease of installation and maintenance. XCBC
and larger units are furnished with hinges, and stainless
steel cover bolts. The covers are removable for clear access
to breakers. For XCBA and XCBB units, hinge and mounting
pan are optional.
The front mounted circuit breaker handle is padlockable in
either “on” or “off” position.

Optional XCBH 2-2 handle shown;
standard handle is XBO.

High interrupting capacity breakers are also available in
comparable size.

Approvals:
Enclosure Certifications

E81696

Compliances:
Class I, Groups B, C, D
Class II, Groups E, F, G
NEMA 4, 7, 9
UL Classified Enclosure

Optional XCBH Style
“Classic”, larger handle.
Special 1" – 11 1/2" NPSM opening
required for installation.
Enclosure

Standard XBO Style
“New”, spring loaded, compact
adjustable design, ease of assembly
and less expensive.
Standard 3/4 – 14 NPSM opening
required for installation.

UL Classified
Enclosure Rating

XCBA, XCBB, XCBC, XCBD, XCBE, XCBF,
XCBG

Class 1, Grps BCD

XCBA N4, XCBB N4, XCBC N4, XCBD N4,
XCBE N4, XCBF N4, XCBGN4

Class 1, Grps CD

256
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 257

Motor Control Explosionproof Circuit Breakers - Disconnect Switches

Molded Case Circuit Breaker Enclosures (Breaker Included)
Breaker

Frame

Interrupting

Size

Rating

Catalog No.
Volts

14,000

100/150

3 Pole

Rating

Non-Interchangeable

Non-Interchangeable

15

XCBA-N4-15E42*

XCBA-N4-15E43*

20

XCBA-N4-20E42*

XCBA-N4-20E43*

30

XCBA-N4-30E42*

XCBA-N4-30E43*

40

XCBA-N4-40E42*

XCBA-N4-40E43*

50

XCBA-N4-50E42*

XCBA-N4-50E43*

480

60

XCBA-N4-60E42*

XCBA-N4-60E43*

Interrupting

Volt AC

70

XCBA-N4-70E42*

XCBA-N4-70E43*

Capacity

250

80

XCBB-N4-80E42*

XCBB-N4-80E43*

at 480

Volt DC

90

XCBB-N4-90E42*

XCBB-N4-90E43*

100

XCBB-N4-100E42*

XCBB-N4-100E43*

110

XCBB-N4-110E42*

XCBB-N4-110E43*

125

XCBB-N4-125E42*

XCBB-N4-125E43*

150

XCBB-N4-150E42*

XCBB-N4-150E43*

15

XCBA-N4-15E62*

XCBA-N4-15E63*

20

XCBA-N4-20E62*

XCBA-N4-20E63*

30

XCBA-N4-30E62*

XCBA-N4-30E63*

40

XCBA-N4-40E62*

XCBA-N4-40E63*

14,000
Amperes

600

50

XCBA-N4-50E62*

XCBA-N4-50E63*

Interrupting

Volt AC

60

XCBA-N4-60E62*

XCBA-N4-60E63*

Capacity

250

70

XCBA-N4-70E62*

XCBA-N4-70E63*

at 600

Volt DC

80

XCBB-N4-80E62*

XCBB-N4-80E63*

90

XCBB-N4-90E62*

XCBB-N4-90E63*

100

XCBB-N4-100E62*

XCBB-N4-100E63*

110

XCBB-N4-110E62*

XCBB-N4-110E63*

125

XCBB-N4-125E62*

XCBB-N4-125E63*

150

XCBB-N4-150E62*

XCBB-N4-150E63*

70

XCBC-N4-70JN2*

XCBC-N4-70JN3*

90

XCBC-N4-90JN2*

XCBC-N4-90JN3*

Volt AC

18,000

225/250

2 Pole

Amperes

Volt AC

100/150

Catalog No.

Amp

Amperes

600

100

XCBC-N4-100JN2*

XCBC-N4-100JN3*

Interrupting

Volt AC

125

XCBC-N4-125JN2*

XCBC-N4-125JN3*

Capacity

250

150

XCBC-N4-150JN2*

XCBC-N4-150JN3*

at 600

Volt DC

175

XCBC-N4-175JN2*

XCBC-N4-175JN3*

200

XCBC-N4-200JN2*

XCBC-N4-200JN3*

225

XCBC-N4-225JN2*

XCBC-N4-225JN3*

250

XCBC-N4-250JN2*

XCBC-N4-250JN3*

Volt AC

* Circuit breaker brand suffix:
W-Cutler-Hammer (Westinghouse)

G-General Electric

S-Square-D

8B–2

Breaker

T-I.T.E. (Siemens)

257
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 258

Motor Control Explosionproof Circuit Breakers - Disconnect Switches
Molded Case Circuit Breaker Enclosures (Breaker Included)
Breaker

Breaker

Frame

Interrupting

Catalog No.

Size

Rating

Volts

8B–3

22,000

400

3 Pole

Rating

Non-Interchangeable

Non-Interchangeable

100

XCBD-N4-100KN2*

XCBD-N4-100KN3*

125

XCBD-N4-125KN2*

XCBD-N4-125KN3*

150

XCBD-N4-150KN2*

XCBD-N4-150KN3*

600

175

XCBD-N4-175KN2*

XCBD-N4-175KN3*

Interrupting

Volt AC

200

XCBD-N4-200KN2*

XCBD-N4-200KN3*

Capacity

250

225

XCBD-N4-225KN2*

XCBD-N4-225KN3*

at 600

Volt DC

250

XCBE-N4-250KN2*

XCBE-N4-250KN3*

300

XCBE-N4-300KN2*

XCBE-N4-300KN3*

350

XCBE-N4-350KN2*

XCBE-N4-350KN3*

400

XCBE-N4-400KN2*

XCBE-N4-400KN3*

22,000

250

XCBE-N4-250LI2*

XCBE-N4-250LI3*

Amperes

600

300

XCBE-N4-300LI2*

XCBE-N4-300LI3*

Interrupting

Volt AC

350

XCBE-N4-350LI2*

XCBE-N4-350LI3*

Capacity

250

400

XCBE-N4-400LI2*

XCBE-N4-400LI3*

at 600

Volt DC

500

XCBF-N4-500LI2*

XCBF-N4-500LI3*

600

XCBF-N4-600LI2*

XCBF-N4-600LI3*

Volt AC

800

2 Pole

Amperes

Volt AC

600

Catalog No.

Amp

22,000

600

400

XCBF-N4-400MI2*

XCBF-N4-400MI3*

Amperes

Volt AC

500

XCBF-N4-500MI2*

XCBF-N4-500MI3*

Interrupting

250

600

XCBF-N4-600MI2*

XCBF-N4-600MI3*

Capacity

Volt AC

700

XCBF-N4-700MI2*

XCBF-N4-700MI3*

800

XCBF-N4-800MI2*

XCBF-N4-800MI3*

at 600 Volt AC

Note: For Interchangeable Trip substitute an “I” for “N” in the Catalog Number.
(Example: XCBC-N4-70JI2)

Fusible Disconnect Switches
Horsepower

Horsepower

Rating

Rating

Amp

Catalog No.

at 480 Volts

at 600 Volts

Rating

3 Pole

20

20

30

XCBA-N4-30DF3*

40

50

60

XCBA-N4-60DF3*

75

75

100

XCBB-N4-100DF3*

125

150

200

XCBC-N4-200DF3*

Note: (3) Class “J” fuses are optional in the above catalog numbers.
* Circuit breaker brand suffix:
W-Cutler-Hammer (Westinghouse)

G-General Electric

S-Square-D

T-I.T.E. (Siemens)

258
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 259

Motor Control Explosionproof Circuit Breakers - Disconnect Switches
Non-Fused Disconnect Switches
Horsepower

Rating

Rating

Amp

at 480 Volts

at 600 Volts

Rating

Catalog No.
3 Pole

20

25

30

XCBA-N4-30DN3

40

60

60

XCBA-N4-60DN3

75

75

100

XCBB-N4-100DN3

125

150

200

XCBC-N4-200DN3

8B–4

Horsepower

Circuit Breaker Enclosure Only
Breaker Frame Size

Trip Range

Catalog Number

100

15-70

XCBA-N4

100/150

80-150

XCBB-N4

225/250

70-250

XCBC-N4

400

100-225

XCBD-N4

400/600

250-400

XCBE-N4

600/800

400-800

XCBF-N4

1200

800-1200

XCBG-N4

CIRCUIT BREAKERS and DISCONNECT OPTIONS
Description

Suffix

Auxiliary Switch 1A and 1B Contacts
Auxiliary Switch 2A and 2B Contacts
Bell Alarm (Specify No. of Contacts)
Breather/Drain - installed in bottom
Breather and Drain installed
High Interrupting Capacity Breaker
Epoxy Coating (External), (Specify Color)
Epoxy Coating (Internal and External), (Specify Color)
Substitute MCP for Breaker
Phenolic Nameplate (Specify Legend)
Shunt Trip (Specify Voltage Rating)
Undervoltage Release (Specify Voltage Rating)
Other / Special

AS1
AS2
BA
E
EE
HI
LI
L2
M
NP
ST
UV
Z

Available On
Circuit
Disconnect
Breaker
Switch

•
•
•
•
•
•
•
•
•
•
•
•
•

Universal
Enclosure
Only

•
•
•
•
•
•
•

•
•
•
•
•

•

Data Dimensions

Enclosure

Width

Nominal Inside

Overall

Mounting

Mounting

Conduit

Dimensions

Dimensions

CL to CL

Bolt

Dimension

Length

Depth

A

B

C

E

Conduit

Shipping

# of Holes

Weight

F

Size

D

G

Size

Top/Bottom

Pounds

XCBA-N4

6

11

5

9 1/4

14 1/4

9

9 1/8

7 1/2

7/16

2 1/2

—

1 1/4

1

28

XCBB-N4

6

13

5

9 1/4

16 1/4

9

9 1/8

9 1/2

3/8

2 1/2

—

2

1

31

XCBC-N4

7

18

5

10 3/8

21 5/8

9

9 3/4

14 1/2

3/8

2 3/4

—

2 1/2

1

47

XCBD-N4

12

20

5

16 1/4

24 1/4

10

15 3/4

14 3/8

1/2

3 1/4

2 1/2

1

108

XCBE-N4

12

24

6

16 1/4

28 1/4

11

15 3/4

18 3/8

1/2

3 5/8

—
2 7/8

3

2

131

XCBF-N4

12

36

8

16 1/4

40 1/4

13 1/2

15 3/4

29

5/8

4 1/2

3 3/8

4

2

237

XCBG-N4

12

46

8

16 1/4

50 1/4

13 3/8

15 3/4

39

5/8

4 1/2

3 3/8

4

2

286

All enclosures have 1/2" NPT top and bottom for breather drain.

259
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 260

Motor Control Explosionproof Motor Starters

Features:

8C–1

• Lightweight, corrosion resistant, copper-free aluminum
alloy (0.3% max. copper content).
• Uniform wall thickness (not ribbed) for versatility of
conduit openings assuring 5 full thread engagement and
maximum available area for conduit drilling and tapping.
• Captive stainless steel cover bolts resist corrosion and
cannot get lost.
• Ground lug is highly visible and accessible.
• Bolted flange design provides clear access to internal
components.
• Rugged cast aluminum handle allows locking in “on” or
“off” position with as many as three padlocks.
• Clevis assembly allows closing of door with breaker
handle assembly in any position without damage to
breaker and without internal mounting hardware.
• All operating shafts are stainless steel for corrosion
resistance.
• Durable cast-on lugs cannot get lost.
• Backpan accommodates most popular brands of circuit
breaker and motor circuit protectors and motor starters.
• Two predrilled and tapped operator holes furnished with
explosionproof plugs for field installation of pilot devices.
• Two additional optional holes available.
• Aluminum hinges with stainless steel hinge pins are “liftoff” so the cover can be easily removed.

XCBSLQN4

• Easily adjustable reset button allows for starter changes in
the field.
• N4 gasket furnished as standard on combination starters.
• Narrow design on combination starter through size 2
allows closer spacing on switchracks while providing
ample room to mount control transformer on the backpan.
• XCBSAQ and XCBSBQ provided with XBO breaker handle
as standard.

Compliances:
• NEC: Class I, Groups B, C, D
Class II, Groups E, F, G
Class III

Certifications

• UL Standard 1203
Hazardous (Classified) Locations

C

CLASSIFIED E81696
CERTIFIED LR 36172

• CSA Standard C22.2 No. 30
• NEMA: 3, 3R, 4, 7BCD, 9EFG, 12

Note: Consult Factory for approvals and certifications on
specific enclosures.
260
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 261

Motor Control Explosionproof Motor Starters

8C–2

Universal Enclosures Only
(does not include breaker or starter)
Class I, Groups C and D; Class II, Groups E, F & G;
Class III, Type 3, 3R, 4,7CD, 9EFG, 12

Class I, Groups C and D; Class II, Groups E, F & G;
Class III, Type 7CD, 9EFG Type 4

For two-speed, Y-Delta, reduced voltage, or multiple starter packages consult factory for availability.
261
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 262

Motor Control Explosionproof Motor Starters
Combination Starter Enclosures (includes breaker and
starter) Full voltage non-reversing
8C–3
262
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 263

Motor Control Explosionproof Motor Starters

8C–4

Combination Starter Enclosures (includes breaker and
starter) Full voltage reversing

Magnetic Full Voltage Starter Enclosures (includes starter)

263
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 264

Motor Control Explosionproof Motor Starters
Options, Dimensions and Ordering Instructions

8C–5

Description

Suffix

Combination
Starter

Start/Stop Dual Pushbutton (1NO Start, 1NC Stop)

A

Green Start Pushbutton (1NO)

A1

Red Stop Pushbutton (1NC)

A2

Red Stop Pushbutton, Mushroom Head (1NC)

A3

Black Pushbutton (1NO, 1NC)

A4

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Auxiliary Switch on Breaker (1A and 1B Contacts)

AS1

Auxiliary Switch on Breaker (2A and 2B Contacts)

AS2

Hand-Off-Auto Selector Switch

B

Selector Switch (2-Position) (1NO, 1NC)

B1

Bell Alarm Switch on Breaker (Specify No. of Contacts)

BA

Pilot Light 120 Volt AC (•See Color Table)

C1*

Pilot Light with Guard 120 Volt AC (•See Color Table)

CG1*

Push-to-Test Light 120 Volt AC (1NO, 1NC) (•See Color Table)

CP1*†

Breather/Drain Installed in Bottom

E$

Breather and Drain Installed

EE$

Auxiliary Contacts on Starter (+NO, -NC) (Specify No. of Contacts)

G (+ -)

Time Delay Relay-On Delay (Specify Range)

H1

Time Delay Relay-Off Delay (Specify Range)

H2

8-Point Terminal Strip

K

Epoxy Coating External Only (Specify Color)

L1

Epoxy Coating External and Internal (Specify Color)

L2

Lamacoid Nameplate (Specify Legend)

NP

Overload Heaters (Specify Full Load Amps)

OL

Control Relay (Description Required)

R

Space Heater (Specify Wattage)

S

Shunt Trip on Breaker (Specify Voltage)

ST

50 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T1F

100 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T2F

150 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T3F

200 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T4F

250 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T5F

300 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T6F

Other Control Transformer (Specify VA, Pri. And Sec.)

T7

Undervoltage Release on Breaker (Specify Voltage Rating)

UV

Internal Control Wiring

W

Other (Specify)

Z

*Color Table

R-Red

G-Green

A-Amber

B-Blue

Available On
Non-Combination
Starter

Universal
Enclosure Only

•
•
•
•
•

•
•
•
•
•

•
•

•
•

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

•
•
•
•
•

•
•
•

•
•
•
•
•
•
•
•
•
C-Clear

•
W-White

† Not available in Group B applications
†† Fuses Included
$ for Group B applications add H to the suffix

264
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 265

Motor Control Explosionproof Motor Starters

DIMENSIONS
Nominal Dimensions In Inches
A

B

C

D

E

11 1/8

Est.
F

G

Ship.
Wt.

Cond.
Size

$ *XCBSAQ-N4 062305

4 1/8

25 1/2

26 15/16

9 11/16

2 1/2

3&5

61

1 1/2

$ *XCBSBQ-N4 072706

4 3/4

29 7/8 11 13/16

31 1/8

10 1/2

2 13/16

3&5

87

1 1/2

18 3/8 16 15/16

XCBSLQ-N4

122408

15 3/4

XCBSMQ-N4

123608

15 3/4

28 1/4

12 15/16

3

3&5

160

2

29

16 15/16

40 1/4

13 3/8

3 5/8

3&5

260

2 1/2

XCBSN-N4

164610

XCMRSG-N4

121808

19 3/4

39

21 3/4

50 7/8

16 7/16

4 7/8

3&5

420

4

15 3/4

14 1/8

17

22 1/4

12 5/8

2 13/16

3&6

100

1 1/4

XCMRSK-N4
XCMRSP-N4

122406

15 3/4

18 3/8

17

28 1/4

10 15/16

3 5/16

3&5

130

2

183608

21 3/4

29

23 3/4

40 7/8

14 3/4

4 1/8

3&5

395

2

†XMSB

081006

10 3/4

6 1/2

12

13 3/8

8 1/4

2 3/8

3&6

36

1

†XMSD

101406

13

10 5/8

14

17 3/8

8 3/8

2 3/4

3&6

55

1 1/2

†XMSH

121808

15 3/4

14 1/8

17

22 1/4

10 3/4

3 1/2

3&6

105

2 1/2

†XMSQ

183610

21 3/4

29

23 3/4

40 7/8

14 7/8

4 5/16

3&6

380

3

$ *† XMRSC

101406

10 5/8

13

18

13 3/8

8 3/8

2 1/4

3&5

55

1

$ *† XMRSF

121206

8 5/8

15 3/4

17

16 1/4

8 15/16

3

3&6

85

1 1/2

$ *† XMRSO

181808

13

21 3/4

23 3/4

22 7/16

12 7/16

3 7/8

3&6

190

2 1/2

Standard conduit openings at locations 1 and 2, control circuit opening 3/4” NPT at locations shown in
column “G”. Each housing has one 1/2” NPT top & bottom for breather and drain.
*

Mounting feet on top and bottom.

†

No breaker handle furnished.

$

Use view “B” for mounting dimensions.

265
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

8C–6

Enclosure

Nom.
Inside
Dim.

15599 Sec.8 12/9/01 11:17 AM Page 266

Explosionproof Enclosures & Components - IEC Motor Control

8D–1

Explosionproof enclosures suitable for housing IEC
(International Electrotechnical Commission) style motor
starters and combination starters. Sizes from 8” x 8” x 4”
up to 12” x 18” x 6”. Design options include: pushbutton
and switch operators, pilot lights, push-to-test lights,
breather/drains, auxiliary contacts, Lamacold™ nameplates,
and control transformers with fuse blocks.
Enclosures are classified by UL/cUL as to explosion
and fire hazards.
Compliances:
Class I, Groups C, D
Class II, Groups E, F, G
Type 4
IEC Motor Starters - Starters Included

IEC Combination Motor Starters - Components Included

For ABB Components

For ABB Components

Catalog
Number

Enclosure
Size

Amp
Rating

HP at
480 Volts

Catalog
Number

Enclosure
Size

Amp
Rating

HP at
480 Volts

XSIAA9
XSIAA11
XDIAA17
XSIAA25
XSICA28
XSICA32
XSICA41
XSICA54
XSIDA65
XSIDA80
XSIEA110

XCE 080804
XCE 080804
XCE 080804
XCE 080806
XCE 101006
XCE 101006
XCE 101006
XCE 101006
XCE 101206
XCE 101206
XCE 1014D6

9
11
17
25
28
32
41
54
65
80
110

5
7.5
10
15
20
25
30
40
50
60
75

XCIAA9
XCIAA11
XCIAA17
XCIAA25
XCIAA28
XCIAA32
XCIAA41
XCIAA54
XCIAA65
XCIBB80
XCIBB110

XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 121806
XCE 121806

9
11
17
25
28
32
41
54
65
80
110

5
7.5
10
15
20
25
30
40
50
60
75

For Cutler-Hammer Components
XSIAH10
XSIAH12
XSIAH18
XSIAH25
XSICH32
XSICH37
XSICH44
XSICH60
XSIDH73

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

080804
080804
080804
080804
101006
101006
101006
101006
101206

For Cutler-Hammer Components

9
12
18
25
32
37
44
60
73

5
7.5
10
15
20
25
30
40
50

9
12
17
25
28
32
40
50
65
80
95

5
7.5
10
15
20
25
30
40
50
60
75

9
12
18
25
32
37
40
50
65
80

5
7.5
10
15
20
25
30
40
50
60

XCIAH10
XCIAH12
XCIAH18
XCIAH25
XCIAH32
XCIAH37
XCIAH44
XCIAH60
XCIAH73

For Siemens Components
XSIAS9
XSIAS12
XSIAS17
XSIAS25
XSICS28
XSICS32
XSICS40
XSICS50
XSIDS65
XSIDS80
XSIDS95

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

080804
080804
080804
080804
101006
101006
101006
101006
101206
101206
101206

266

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

080804
080804
080804
080806
080806
101006
101006
101006
101206
101206

1014D6
1014D6
1014D6
1014D6
1014D6
1014D6
1014D6
1014D6
1014D6

10
12
18
25
32
37
44
50
73

5
7.5
10
15
20
25
30
40
50

9
12
17
25
28
32
40
50
65
80
95

5
7.5
10
15
20
25
30
40
50
60
75

9
12
18
25
32
37
40
50
65
80

5
7.5
10
15
20
25
30
40
50
60

For Siemens Components
XCIAS9
XCIAS12
XCIAS17
XCIAS25
XCIAS28
XCIAS32
XCIAS40
XCIAS50
XCIBS65
XCIBS80
XCIBS95

For Square D Components
XSIAD9
XSIAD12
XSIAD18
XSIBD25
XSIBD32
XSICD37
XSICD40
XSICD50
XSIDD65
XSIDD80

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 121806
XCE 121806
XCE 121806

For Square D Components
XCIAD9
XCIAD12
XCIAD18
XCIAD25
XCIAD32
XCIAD37
XCIAD40
XCIAD50
XCIAD65
XCIBD80

XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 121806

For Group B applications, consult factory

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 267

Explosionproof Enclosures & Components - IEC Motor Control
IEC Motor Starters
Enclosures only

IEC Combination Motor Starters
Enclosures only

Catalog
Number

Enclosure
Size

For ABB Components
Amp
Rating

HP at
480 Volts

Catalog
Number

Enclosure
Size

Amp
Rating

HP at
480 Volts

XSIAA
XSIAA
XSIAA
XSIAA

XCE
XCE
XCE
XCE

080804
080804
080804
080804

9
11
17
25

5
7.5
10
15

XCIAA
XCIAA
XCIAA
XCIAA

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

9
11
17
25

5
7.5
10
15

XSICA
XSICA
XSICA
XSICA

XCE
XCE
XCE
XCE

101006
101006
101006
101006

28
32
41
54

20
25
30
40

XCIAA
XCIAA
XCIAA
XCIAA

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

28
32
41
54

20
25
30
40

XSIDA
XSIDA
XSIEA

XCE 101206
XCE 101206
XCE 1014D6

65
80
110

50
60
75

XCIAA
XCIBB
XCIBB

XCE 1014D6
XCE 121806
XCE 121806

65
80
110

50
60
75

For Cutler-Hammer Components

8D–2

For ABB Components

For Cutler-Hammer Components

XSIAH
XSIAH
XSIAH
XSIAH

XCE
XCE
XCE
XCE

080804
080804
080804
080804

10
12
18
25

5
7.5
10
15

XCIAH
XCIAH
XCIAH
XCIAH

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

10
12
18
25

5
7.5
10
15

XSICH
XSICH
XSICH
XSICH
XSIDH

XCE
XCE
XCE
XCE
XCE

101006
101006
101006
101006
101206

32
37
44
60
73

20
25
30
40
50

XCIAH
XCIAH
XCIAH
XCIAH
XCIAH

XCE
XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6
1014D6

32
37
44
60
73

20
25
30
40
50

For Siemens Components

For Siemens Components

XSIAS
XSIAS
XSIAS
XSIAS

XCE
XCE
XCE
XCE

080804
080804
080804
080804

9
12
17
25

5
7.5
10
15

XCIAS
XCIAS
XCIAS
XCIAS

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

9
12
17
25

5
7.5
10
15

XSICS
XSICS
XSICS
XSICS

XCE
XCE
XCE
XCE

101006
101006
101006
101006

28
32
40
50

20
25
30
40

XCIAS
XCIAS
XCIAS
XCIAS

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

28
32
40
50

20
25
30
40

XSIDS
XSIDS
XSIDS

XCE 101206
XCE 101206
XCE 101206

65
80
95

50
60
75

XCIBS
XCIBS
XCIBS

XCE 121806
XCE 121806
XCE 121806

65
80
95

50
60
75

For Square D Components

For Square D Components

XSIAD
XSIAD
XSIAD
XSIBD

XCE
XCE
XCE
XCE

080804
080804
080804
080806

9
12
18
25

5
7.5
10
15

XCIAD
XCIAD
XCIAD
XCIAD

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

9
12
18
25

5
7.5
10
15

XSIBD
XSICD
XSICD
XSICD

XCE
XCE
XCE
XCE

080806
101006
101006
101006

32
37
40
50

20
25
30
40

XCIAD
XCIAD
XCIAD
XCIAD

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

32
37
40
50

20
25
30
40

XSIDD
XSIDD

XCE 101206
XCE 101206

65
80

50
60

XCIAD
XCIBD

XCE 1014D6
XCE 121806

65
80

50
60

267
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 268

Explosionproof Enclosures & Components - IEC Motor Control
Diagram Specifications
Starters Diagram

Catalog
No.

Base
Enclosure
XCE

A

Overall
B

C

MTG
E

MTG
F

MTG
BOLT

080804
080806
101006
101206
1014D6

11.38
11.38
13.38
13.38
13.38

11.38
11.38
13.38
15.38
17.38

7.75
9.75
9.62
10.25
9.75

4.25
4.25
6.5
8.5
10.62

11
11
13
13.25
13.25

3/8
3/8
3/8
3/8
3/8

2.81
3.81
3.88
4.13
2.88

2.25
2.25
2.50
2.5
2.5

1-1/2
1-1/2
2
2
2

26
30
46
48
51

13.38
16.25

17.38
22.25

9.75
10.12

10.62
14.12

13.25
15.75

3/8
1/2

2.88
4.00

3.0
3.0

1-1/2
2

51
95

Conduit Location Conduit
D
G
Size

Weight

Starters

8D–3

XSIA
XSIB
XSIC
XSID
XSIE

Combinations
XCIA
XCIB

1014D6
121806

Options
Suffix

Combination
Starter

Available On
Non-Combination
Starter

Start/Stop Dual Pushbutton
(1NO Start, 1NC Stop)

A

•

•

•

Green Start Pushbutton (1NO)

A1

•

•

•

Red Stop Pushbutton (1NC)

A2

•

•

•

Red Stop Pushbutton,
Mushroom Head (1NC)

A3

•

•

•

Black Pushbutton (1NO, 1NC)

A4

•

•

•

Hand-Off-Auto Selector Switch

B

•

•

•

Selector Switch (2-Position)
(1NO, 1NC)

B1

•

•

•

Pilot Light 120 Volt AC
(*See Color Table)

C1*

•

•

•

Pilot Light with Guard 120 Volt AC
(*See Color Table)

CG1*

•

•

•

Push-to-Test Light 120 Volt AC
(1NO, 1NC) (*See Color Table)

CP1*†

•

•

•

E

•

•

•

EE

•

•

•

G(+ -)

•

•

Lamacold Nameplate (Specify Legend) NP

•

•

50 VA Control Transformer 480V Pri,
120V Sec. W/Fuse Block

T1F

•

•

100 VA Control Transformer 480V Pri,
120V Sec. W/Fuse Block

T2F

•

•

150 VA Control Transformer 480V Pri,
120 V Sec. W/Fuse Block

T3F

•

•

200 VA Control Transformer 480V Pri,
120V Sec. W/Fuse Block

T4F

•

•

Description

Combination Diagram

Breather/Drain Installed in Bottom
Breather and Drain Installed
Auxiliary Contacts on Starter
(+NO,-NC) (Specify No. of Contacts)

Universal
Enclosure Only

•

*Color Table R-Red G-Green A-Amber B-Blue C-Clear W-White
†Not available in Group B applications

268
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 269

Motor Control Explosionproof Motor Starters
MANUAL MOTOR STARTERS

Catalog
Number

Number
of Hubs

Conduit
Size

Poles

Mfg. Bolt
Size

Weight
(lbs.)

XLSC21 †*

2

1/2

1

1/4"

2 3/4

XLSC22 †*

2

1/2

2

1/4"

2 3/4

XLSC31 †*

2

3/4

1

1/4"

2 3/4

XLSC32 †*

2

3/4

2

1/4"

2 3/4

XLSC2 **

2

1/2

-

1/4"

2 3/4

XLSC3 **

2

3/4

-

1/4"

2 3/4

8E–1

Type XLS Manual Motor Starting Switches are furnished complete
with switch and interchangeable heaters. The XLS housings are
cast aluminum alloy and have a trouble free operating lever
threaded through the cover.

† = HP Rating
* = Heater Table

MAXIMUM HORSEPOWER RATINGS
†Adalet
Symbol
1B
2B
1C
2C

Make & Catalog No.
Westinghouse MST01
Westinghouse MST02
GE CR101Y
GE CR101H

Poles
1
2
1
2

115-230
Volts AC
1 H.P.
1 H.P.
1 H.P.
1 H.P.

32
Volts DC
1/4 H.P.
1/4 H.P.

115
Volts DC
1/4 H.P.
1 H.P.
1 H.P.
1 H.P.

230
Volts DC
1/4 H.P.
1 H.P.
1/4 H.P
1 H.P.

The following tables list interchangeable Heater elements for each
manufacturer. The elements are not interchangeable between manufacturers. The heater elements listed are for motors rated 40°C
continuous. For motors rated 50°C or 55°C, multiply by 0.9 and
use this value to select heaters.

WESTINGHOUSE
*Adalet
Symbol
1
2
3
4
5
6
7
8
9
10
11
12
13

Motor
Full Load
Current
.40 - .43
.44- -.48
.49 - .53
.54 - .58
.59 - .64
.65 - .71
.72 - .78
.79 - .87
.88 - .95
.96 – 1.03
1.04 – 1.15
1.16 – 1.27
1.28 – 1.35

*Adalet
Symbol
14
15
16
17
18
19
20
21
22
23
24
25
26

1
2
3
4
5
6
7
8
9
10
11
12
13
14

.48
.53
.58
.65
.71
.78
.86
.95
1.04
1.14
1.25
1.37
1.49
1.63

15
16
17
18
19
20
21
22
23
24
25
26
27
28

Motor
Full Load
Current
1.36 – 1.51
1.52 – 1.67
1.68 – 1.83
1.84 – 1.99
2.00 – 2.23
2.24 – 2.47
2.48 – 2.71
2.72 – 2.95
2.96 – 3.27
3.28 – 3.59
3.60 – 3.99
4.00 – 4.39
4.40 – 4.79

*Adalet
Symbol
27
28
29
30
31
32
33
34
35
36
37
38
39

Motor
Full Load
Current
4.80 – 5.26
5.27 – 5.83
5.84 – 6.39
6.40 – 7.03
7.04 – 7.74
7.75 – 8.46
8.47 – 9.35
9.36 – 10.30
10.31 – 11.35
11.36 – 12.47
12.48 – 13.67
13.68 – 15.12
15.13 – 16.00

29
30
31
32
33
34
35
36
37
38
39
40
41

5.90
6.41
6.98
7.60
8.25
8.95
9.75
10.60
11.40
12.50
13.60
14.80
16.00

How To Order: To determine the
complete catalog number, select the unit
wanted and add the Adalet symbol
numbers for the make of starter wanted
and the heaters required. Select heaters
from charts.
** Enclosure less switch - for CSA certified
switches rated 600V max, 30 amp max,
15HP max.

GE
1.78
1.95
2.13
2.32
2.53
2.76
3.01
3.27
3.56
3.88
4.22
4.60
5.00
5.43

Certifications
Class I, Groups C & D
Class II, Groups E, F & G

LR36172
269

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 270

Motor Control Explosionproof Motor Starter/Protector

8E–2
Compliances:
• NEC: Class I, Groups C, D
Class II, Groups E, F, G
• UL Standard 1203
Hazardous (Classified) Locations
• CSA Standard 22.2
• NEMA: 7CD, 9EFG
Approvals:
• UL Classified
Class I, Groups C, D
Class II, Groups E, F, G
• CSA Certified
Class I, Groups C, D
Class II, Groups E, F, G
270
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 271

Explosionproof Pilot Devices

CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G

APPLICATIONS

9A–1

Adalet operators are for use in control circuits functioning in
environments containing hazardous gases, vapors or dusts.
These heavy duty pilot lights, pushbuttons and selector
switches are suitable for use in Class I, Groups B, C & D
hazardous gas; Class II, Groups E, F & G dust atmospheres.
Most are suitable for weather-tight (N4) applications.

FEATURES:
• Most operators are suitable for NEMA 3, 4, NEMA 7, 9, raintight, water-tight in hazardous environments.
• Two lengths available for either surface or panel mount.
• Knurled caps are standard with black anodized finish.
• Optional: specify color-coding of operator caps (no additional
cost).
• Pilot light transformers available for 240 volts.
• Special length pilot light wiring leads available.
• Screw terminals available suffix T.
• Coated to minimize corrosion and provide for ease of
installation.
• Operators are 3/4” NPSM standard.
• Stainless steel shafts are standard (except pilot light
pushbutton operator).
Consult factory for UL/CSA certification availability.
Compliances: NEC Class I, Groups B, C & D - Class II, Groups
E, F, G
UL Standard 698 - Standard C22.2 No. 30

Notes:
Where reference is made to Class I and Class II hazardous locations, the
equipment is suitable for use in both Division 1 and Division 2 hazardous
locations.

The Adalet engineering department is available to assist in the selection of custom explosionproof housings for your products.
271
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 272

Explosionproof and Dust-tight Pilot Lights

CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Explosionproof pilot lights are suitable for panel or surface mount
applications. All pilot lights are of sealed construction and can be relamped
from the front by removal of lens cap.
All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8”
flexible leads, other lengths on special order, or screw terminals.
All lens caps are black anodized aluminum finish. For color coding we will
furnish at no additional charge the following color combinations: lens ambercap gold, lens blue-cap blue, lens clear-cap natural aluminum, lens green-cap
green, lens red-cap red, lens white-cap natural aluminum. Specify on orders.

9A–2

Maximum installation thickness 1 15/16” on Long Series, 3/4” on Short
Series.
This standard series of pilot lights is equipped with candelabra base
receptacles and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available
with 6, 12, 24, 30, 50, 75 and 135 volt lamps. Specify voltage desired.
Catalog
Number
Long Series

Catalog
Number
Short Series

Weight
Each
Pounds

Description

XLA

XLSA

Amber Lens

1/2

XLB

XLSB

Blue Lens

1/2
1/2

XLC

XLSC

Clear Lens

XLG

XLSG

Green Lens

1/2

XLR

XLSR

Red Lens

1/2

XLW

XLSW

White Lens

1/2

*Add suffix T to P/N for screw terminal

This special series of pilot lights is equipped with slide base receptacles
and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12,
24, 48 and 60 volt lamps. Specify voltage desired.

Legend Plates, see page 9A–18

Catalog
Number
Long Series

Catalog
Number
Short Series

Description

Weight
Each
Pounds

XLAS

XLSAS

Amber Lens

1/2

XLBS

XLSBS

Blue Lens

1/2

XLCS

XLSCS

Clear Lens

1/2

XLGS

XLSGS

Green Lens

1/2

XLRS

XLSRS

Red Lens

1/2

XLSWS

White Lens

1/2

XLWS

*Add suffix T to P/N for screw terminal

2 5/16

Pilot Light Transformers
Catalog
Number

Description

Weight Each
Pounds

XLT 240

240 to 120 volt, 6VA

1

One transformer required for each pilot light. Adapter furnished for
mounting on threaded pilot light stem, or can be mounted to housing as
space requires.
272
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 273

Explosionproof and Dust-tight Pilot Lights
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Guarded Pilot Lights

Maximum installation thickness 1 15/16” on Long Series (Panel Mount),
3/4” on Short Series (Surface Mount).
This standard series of pilot lights is equipped with candelabra base receptacles
and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24,
30, 50, 75 and 135 volt lamps. Specify voltage desired.
Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Weight
Each
Pounds

Description

XLA-G

XLSA-G

Amber Lens

1/2

XLB-G

XLSB-G

Blue Lens

1/2

XLC-G

XLSC-G

Clear Lens

1/2

XLG-G

XLSG-G

Green Lens

1/2

XLR-G

XLSR-G

Red Lens

1/2

XLW-G

XLSW-G

White Lens

1/2

*Add suffix T to P/N for screw terminal

This special series of pilot lights is equipped with slide base receptacles
and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12,
24, 48 and 60 volt lamps. Specify voltage desired.
Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Weight
Each
Pounds

Description

XLAS-G

XLSAS-G

Amber Lens

1/2

XLBS-G

XLSBS-G

Blue Lens

1/2
1/2

XLCS-G

XLSCS-G

Clear Lens

XLGS-G

XLSGS-G

Green Lens

1/2

XLRS-G

XLSRS-G

Red Lens

1/2

XLWS-G

XLSWS-G

White Lens

1/2

*Add suffix T to P/N for screw terminal

Replacement Guarded Lens Cap Assembly
Catalog
Number

Description

Weight Each
Pounds

XLA-GC

Amber Lens

1/8

XLB-GC

Blue Lens

1/8

XLC-GC

Clear Lens

1/8

XLG-GC

Green Lens

1/8

XLR-GC

Red Lens

1/8

XLW-GC

White Lens

1/8

Legend Plates, see page 9A-19.
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

273

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

9A–3

Explosionproof pilot lights are suitable for panel or surface mount applications. All
pilot lights are of sealed construction and can be relamped from the front by
removal of lens cap.
All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible
leads, other lengths on special order, or screw terminals.
All lens caps are black anodized aluminum finish.

15599 Sec.9 12/9/01 11:19 AM Page 274

Explosionproof and Dust-tight Pilot Lights

CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Guarded Pilot LED Lights
LED Advantages:
• 10 Year/100,000 hour service life under normal ambient conditions.
• 1x to 4x more energy efficient.
• Improved resistance to shock and vibration.
• LEDs operate significantly cooler than traditional lamps.
• Ultra bright cluster LED’s

9A–4

Explosionproof pilot LED lights are suitable for panel or surface mount
applications. All candelabra base LED lights can be relamped from the front
by removal of the lens cap.
All pilot LED lights are made with 3/4” NPSM threads. All pilot LED lights
have 8” flexible leads, other lengths on special order, or screw terminal.
Screw terminal available suffix T.
All lens caps are black anodized aluminum finish with clear glass lens.
Maximum installation thickness: 1-15/16” on Panel Mount (Long
Series), 3/4” on Surface Mount (Short Series).
Consult Adalet for the availability of other voltages.

Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Description

Weight
Each
Pounds

XLRL-G

XLSRL-G

Red

1/2

XLAL-G

XLSAL-G

Amber

1/2

XLGL-G

XLSGL-G

Green

1/2

XLWL-G

XLSWL-G

White

1/2

XLBL-G

XLSBL-G

Blue

1/2

*Add suffix T to P/N for screw terminal

274
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 275

Explosionproof and Dust-tight Pilot Light Push Buttons
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7, 9
Indicator Light/Push Button
Push-To-Test Operators

For use with
series BT
contact blocks

Description of operators only

9A–5

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness 1 15/16” panel mount,
3/4” surface mount.
Furnished standard with 120 volt slide base lamp. Also available for 6,
12, 24, 28, 48 and 60 volts. Specify when ordering.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with the operators.
Order from page 9A–20. For NEMA 4 application, add boot and special
legend plate, see page 9A–19.

Weight
Each
Pounds

For Panel Mounting
XLPA

Amber Lens

3/4

XLPB

Blue Lens

3/4

XLPC

Clear Lens

3/4

XLPG

Green Lens

3/4

XLPR

Red Lens

3/4

White Lens

3/4

XLPW

For Surface Mounting
XLPAS

Amber Lens

1/2

XLPBS

Blue Lens

1/2

XLPCS

Clear Lens

1/2

XLPGS

Green Lens

1/2

XLPRS

Red Lens

1/2

XLPWS

White Lens

1/2

Legend Plates, see page 9A–19.

275
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 276

Explosionproof and Dust-tight Push Buttons
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Push Button Operators

9A–6

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness 1 3/4” panel mount,
3/4” surface mount.
All operators have black molded nylon buttons. The exposed metal
parts are black anodized aluminum. For color coding we will furnish at
no additional cost the following color combinations: Red buttons with
red metal caps and green buttons with green metal caps. Metal caps
are also available in blue, gold or clear with black buttons. Specify
colors required.
Red Mushroom head buttons are 1 3/4” diameter anodized aluminum.
Also available in black or green.
XHPBPL has padlock attachment on top of cap allowing operator to be
locked with the push button depressed.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with the operators.
Order from page 9A–20.
XHPPM/XHPPMS require 2" minimum spacing.
For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XHPB

Panel Mount

1/2

XHPBS

Surface Mount

1/2

XHPBM

Red Mushroom Head, Panel Mount

1/2

XHPBMS

Red Mushroom Head, Surface Mount

1/2

XHPBPL

W/Padlock devices, Panel Mount

3/4

XHPBSPL

W/Padlock devices, Surface Mount

3/4

XHPPM*

Push/Pull switches, Panel Mount

3/4

XHPPMS*

Push/Pull switches, Surface Mount

3/4

Legend Plates, see page 9A–19.
*Type BT1 contact blocks are included
For extremely wet-dirty location applications, XHPB and XHPBS series
are available to be used with protective boots, see page 9A–19.

276
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 277

Explosionproof and Dust-tight Push Buttons
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Push Button Operators
1

1 —4
5
1—
16

1

1

4 —2

3 —4

3

1 —4
3

1 —4

13

1

3—
16

5—
16

Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. Maximum installation thickness 1 3/4” panel mount,
3/4” surface mount.
All operators have black molded nylon buttons. The exposed metal
parts are black anodized aluminum. For color coding we will furnish at
no additional cost the following color combinations: Red buttons with
red metal caps and green buttons with green metal caps. Metal caps
are also available in blue, gold or clear with black buttons. Specify
colors required.
Red Mushroom head buttons are 1 3/4” diameter anodized aluminum.
Also available in black or green.
XVHPBPL has padlock attachment on top of cap allowing operator to
be locked with the push button depressed.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with the operators.
Order from page 9A–20.
XVHPPM/XVHPPMS require 2" minimum spacing.

For use with
series BT
contact blocks
3

1 —4
3

1 —4

3

7 EXT.

5 —4

EXT.

Description of operators only

9A–7

1

1 —4

Weight
Each
Pounds

XVHPB

Panel Mount

1/2

XVHPBS

Surface Mount

1/2

XVHPBM

Red Mushroom Head, Panel Mount

1/2

XVHPBMS

Red Mushroom Head, Surface Mount

1/2

XVHPBPL

W/Padlock devices, Panel Mount

3/4

XVHPBSPL

W/Padlock devices, Surface Mount

3/4

XVHPPM*

Push/Pull switches, Panel Mount

3/4

XVHPPMS*

Push/Pull switches, Surface Mount

3/4

Legend Plates, see page 9A–19.
*Type BT1 contact blocks are included
5

1 —8
5

1 —8

1

5—
16

For extremely wet-dirty location applications, XVHPB and XVHPBS
series are available to be used with protective boots, see page 9A–19.
13

3—
16

277
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 278

Explosionproof and Dust-tight Push Buttons
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Dual Push Button Operator or
Maintained Contact Unit
All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness 1 15/16” panel mount,
3/4” surface mount.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with XHD operators.
Order from page 9A–20.
5

9A–8

1 —8

1

1 —4

5

1 —8

For use with
series BT
contact blocks

1

1 —4

1
1 —4
1

1 —4
3

3

4—
16

Description of operators only

Weight
Each
Pounds

XHDPB

Panel Mount - momentary*

1/2

XHDPBS

Surface Mount - momentary*

1/2

XHDMC

Maintained Contact, Panel Mount

1/2

XHDMCS

Maintained Contact, Surface Mount

1/2

*Two contacts in the BT contact block are actuated independently

Furnished with
one
contact block
XHMCD

Description of operators only

Weight
Each
Pounds

Maintained Contact Unit

1

Two Push Buttons, Panel Mount
1

1 —4

1

3

1 —4

1

1 —4

1 —4

1

1 —4

XHMCSD

1

3
1 —4

1 —4

Maintained Contact Unit

1

Two Push Buttons, Surface Mount

1

1 —4

XHMCMD

Maintained Contact Unit

1

Two Push Buttons, Panel Mount
With one mushroom and one
standard button
XHMCMSD

Maintained Contact Unit

1

Two Push Buttons, Surface Mount
With one mushroom and one
standard button

Group CD Only
The XHMCD and XHMCSD maintained contact units require only one
contact block. These units consist of two operators and require two
mounting positions.
Legend Plates, see page 9A–19.

278
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 279

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Selector Switch Operators

For use with
series BT
contact blocks

Description of operators only

9A–9

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used
as 2 position or 3 position by removal of knob and rotating knob
180°. The actuator cam which operates the plungers on the contact
blocks can be readily changed for various contact sequences. FOR 3
POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks
are not included with XHSS operators. Select contact block and
sequence operating cam from contact block page 9A–20.
All operators have black molded nylon knobs. The exposed metal
parts are black anodized aluminum. Metal caps are also available in
blue, gold, clear, red or green with black knobs. Specify colors
required.
Weight
Each
Pounds

XHSS

Panel Mount

1/2

XHSSS

Surface Mount

1/2

XHSC

Spring Return to Center

1/2

from Right and Left
Panel Mount
XHSSC

Spring Return to Center

1/2

XHSR

XHSSR

3 POSITION ONLY

from Right and Left
Surface Mount
Spring Return to Center

1/2

from Right, Maintain Left
Panel Mount
Spring Return to Center

1/2

from Right, Maintain Left
Surface Mount

XHSL

Spring Return to Center

1/2

from Left, Maintain Right
Panel Mount
XHSSL

Spring Return to Center

1/2

from Left, Maintain Right
Surface Mount
XHSSPL

W/padlock device Panel Mount

3/4

XHSSSPL

W/padlock device Surface Mount

3/4

XSSL-4P

Panel Mount, Four Position

3/4

Selector Switch
XSSL-5P

Switch Included

Panel Mount, Five Position

3/4

Selector Switch
XSSS-4P

Surface Mount, Four Position

3/4

Selector Switch
XSSS-5P

Surface Mount, Five Position

3/4

Selector Switch

For extremely wet-dirty location applications, use Protective
Boots Page 9A–19. EXCLUDES PADLOCK DEVICES.

Legend Plates, see page 9A–19.
279

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 280

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Selector Switch Operators

9A–10

Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used as
2 position or 3 position by removal and rotation of the cam actuator.
The cam which operates the plungers on the contact blocks can be
changed for various contact sequences. FOR 3 POSITION, ORDERS
MUST STATE CAM NUMBER. Contact blocks are not included with
XVHSS operators. Select contact block and sequence operating cam
from contact block page 9A–20.
All operators have black molded nylon knobs. The exposed metal parts
are black anodized aluminum. Metal caps are also available in blue,
gold, clear, red or green with black knobs. Specify colors required.

For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XVHSS

Panel Mount

1/2

XVHSSS

Surface Mount

1/2

XVHSSPL

W/padlock device Panel Mount

3/4

XVHSSSPL

W/padlock device Surface Mount

3/4

Legend Plates, see page 9A–19.

For extremely wet-dirty location applications, use Protective
Boots Page 9A–19. EXCLUDES PADLOCK DEVICES.

The selector switch for Series BT blocks have a sequence actuating
cam as an integral part of the operator. THE CAM NUMBER MUST
BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN
ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT
ARRANGEMENT CHARTS, SEE PAGE 9A–20.
280
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 281

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Keylock Selector Switch Operators

Key removable one position only

For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XHKSS

Key Lock Operation

1/2

9A–11

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used
as 2 position or 3 position by removal of knob and rotating knob
180°. The actuator cam which operates the plungers on the contact
blocks can be readily changed for various contact sequences. FOR 3
POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks
are not included with operators. Select contact block and sequence
operating cam from contact block page 9A–20.
The exposed metal parts are black anodized aluminum.

specify right, center or left
Panel Mount
XHKSSS

Key Lock Operation

1/2

Surface Mount
XHKSC

Spring Return to Center

1/2

from Right and Left
Panel Mount
XHKSSC

Spring Return to Center

1/2

from Right and Left

XHKSSR

3 POSITION ONLY

Surface Mount
XHKSR

Spring Return to Center

1/2

from Right, Maintain Left
Panel Mount
Spring Return to Center

1/2

from Right, Maintain Left
Surface Mount

XHKSL

Spring Return to Center

1/2

from Left, Maintain Right
Panel Mount
XHKSSL

Spring Return to Center

1/2

from Left, Maintain Right
Surface Mount

Legend Plates, see page 9A–19.

The selector switch for Series BT blocks have a sequence actuating
cam as an integral part of the operator. THE CAM NUMBER MUST
BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN
ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT
ARRANGEMENT CHARTS, SEE PAGE 9A–20.
281
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 282

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Keylock Selector Switch Operators

9A–12

Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used as
2 position or 3 position by removal and rotation of the cam actuator.
The cam which operates the plungers on the contact blocks can be
changed for various contact sequences. FOR 3 POSITION, ORDERS
MUST STATE CAM NUMBER. Contact blocks are not included with
operators. Select contact block and sequence operating cam from
contact block page 9A–20.
The exposed metal parts are black anodized aluminum.

XVHKSS

XVHKSSS

Key removable one position only

For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XVHKSS

Key Lock Operation,

1/2

Panel Mount

specify right, center or left
XVHKSSS

Key Lock Operation,

1/2

Surface Mount

Legend Plates, see page 9A–19.

The selector switch for Series BT blocks have a sequence actuating
cam as an integral part of the operator. THE CAM NUMBER MUST
BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN
ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT
ARRANGEMENT CHARTS, SEE PAGE 9A–20.
282
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 283

Explosionproof Potentiometer and Switch Operators
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Potentiometer and Switch Operators
Operators are die cast aluminum alloy. The barrels are all 3/4” NPSM
thread. 1/4” diameter shafts. Maximum installation thickness:
1 15/16” panel mount, 3/4” surface mount. XPO-XPOS have knob
and dial marked 1 to 100. Two dial sizes are available. XPOC-XPOCS
have 15 turn counting dial. Operators include 3 pc. coupling and
device mounting bracket.
Weight
Each
Pounds

Description

XPO

Plain Dial, Panel Mount

1/2

XPOS

Plain Dial, Surface Mount

1/2
1/2

XPOL

Plain Dial, Large Size, Panel Mount

XPOSL

Plain Dial, Large Size, Surface Mount

1/2

XPOC

Counting Dial, Panel Mount

3/4

XPOCS

Counting Dial, Surface Mount

3/4

9A–13

Catalog No.

POTENTIOMETER NOT FURNISHED — Consult Factory.

CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7, 9
Manual and Motor Operated Rotating Shafts
XCS manual operated shafts suitable for potentiometers, rheostats
and other devices requiring external adjustment. Includes 3 piece
coupling to compensate for misalignment.
XCF motor operated shafts suitable for tachometers and rotating
equipment with speeds to 5000 rpm. Shaft is ball bearing mounted.
Includes flexible coupling to compensate for misalignment.
Dimension in Inches
Cat. No.

Shaft Dia.

A

B

C

D

E (NPSM)

XCS-1

1/8

6

2 1/2

1

2 1/2

3/4-14

XCS-2

1/4

6

2 1/2

1

2 1/2

3/4-14

XCS-3

5/16

6

2 1/2

1

2 1/2

3/4-14

XCS-4

3/8

6

2 1/2

1

2 1/2

3/4-14

XCS-5

1/2

6

2 1/2

1

2 1/2

3/4-14

XCF-1

1/8

6

2 3/16

1 5/8

2 3/16

1/2-14

XCF-2

1/4

6

2 1/8

1 3/4

2 1/8

3/4-14

XCF-3

5/16

6

2

2

2

1-11 1/2

XCF-4

3/8

6

2

2

2

1-11 1/2

XCF-5

1/2

6

2

2

2

1 1/4-11 1/2

NOTE: NEMA 3, 4 Features Available for XCF Only
283
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 284

Explosionproof Potentiometer and Switch Operators

CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Potentiometer Operators
Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. 1/4” diameter shafts. Maximum installation
thickness: 1 15/16” panel mount, 3/4” surface mount. XVPO-XVPOS
have knob and dial marked 1 to 100. Two dial sizes are available.
XVPOC-XVPOCS have 15 turn counting dial. Operators include 3 pc.
coupling and device mounting bracket.

9A–14

Catalog No.

Description

Weight
Each
Pounds
1/2

XVPO

Plain Dial, Panel Mount

XVPOS

Plain Dial, Surface Mount

1/2

XVPOL

Plain Dial, Large Size, Panel Mount

1/2

XVPOSL

Plain Dial, Large Size, Surface Mount

1/2

XVPOC

Counting Dial, Panel Mount

3/4

XVPOCS

Counting Dial, Surface Mount

3/4

POTENTIOMETER NOT FURNISHED — Consult Factory.

284
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 285

Explosionproof and Dust-tight Pilot Lights
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9

Explosionproof pilot lights are suitable for panel or surface mount applications. All pilot
lights are of sealed construction and can be relamped from the front by removal of
lens cap.
All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible leads,
other lengths on special order, or screw terminal (suffix T).
All lens caps are black anodized aluminum finish.
Maximum installation thickness: 1 15/16” on Long Series, 5/8” on Short Series.
This standard series of pilot lights is equipped with candelabra base receptacles and 6
watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24, 30, 50, 75
and 135 volt lamps. Specify voltage desired.

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Description

Weight
Each
Pounds

XLA-GH

XLSA-GH

Amber Lens

1/2

XLB-GH

XLSB-GH

Blue Lens

1/2

XLC-GH

XLSC-GH

Clear Lens

1/2

XLG-GH

XLSG-GH

Green Lens

1/2

XLR-GH

XLSR-GH

Red Lens

1/2

XLSW-GH

White Lens

1/2

XLW-GH

*Add suffix T to P/N for screw terminal

This special series of pilot lights is equipped with slide base receptacles and 120 volt
5000 hr. avg. lamps with slide base. Also available with 6, 12, 24, 48 and 60 volt
lamps. Specify voltage desired.

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Description

Weight
Each
Pounds

XLAS-GH

XLSAS-GH

Amber Lens

1/2

XLBS-GH

XLSBS-GH

Blue Lens

1/2

XLCS-GH

XLSCS-GH

Clear Lens

1/2

XLGS-GH

XLSGS-GH

Green Lens

1/2

XLRS-GH

XLSRS-GH

Red Lens

1/2

XLWS-GH

XLSWS-GH

White Lens

1/2

*Add suffix T to P/N for screw terminal

Replacement Guarded Lens Cap Assembly
Catalog No.

Description

Weight
Each
Pounds

XLA-GCH

Amber Lens

1/8

XLB-GCH

Blue Lens

1/8

XLC-GCH

Clear Lens

1/8

XLG-GCH

Green Lens

1/8

XLR-GCH

Red Lens

1/8

XLW-GCH

White Lens

1/8

285
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

9A–15

Guarded Pilot Lights for Group B Application

15599 Sec.9 12/9/01 11:19 AM Page 286

Explosionproof and Dust-tight Pilot Lights
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Guarded Pilot LED Lights
for Group B Application
LED Advantages:
• 10 Year/100,000 hour service life under normal ambient conditions.
• 1x to 4x more energy efficient.
• Improved resistance to shock and vibration.
• LEDs operate significantly cooler than traditional lamps.

9A–16

• Ultra bright cluster LED’s.
Explosionproof pilot LED lights are suitable for panel or surface mount
applications. All candelabra base LED lights and can be relamped from
the front by removal of the lens cap.
All pilot LED lights are made with 3/4” NPSM threads. All pilot LED
lights have 8” flexible leads, other lengths on special order, or
screw terminal.
Add suffix T to P/N for screw terminal.
All lens caps are black anodized aluminum finish with clear glass lens.
Maximum installation thickness: 1-15/16” on Panel Mount (Long
Series), 5/8” on Surface Mount (Short Series).
Consult Adalet for the availability of other voltages.
Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Description

Weight
Each
Pounds

XLRL-GH
XLAL-GH
XLGL-GH
XCWL-GH
XLBL-GH

XLSRL-GH
XLSAL-GH
XLSGL-GH
XLSWL-GH
XLSBL-GH

Red
Amber
Green
White
Blue

1/2
1/2
1/2
1/2
1/2

*Add suffix T to P/N for screw terminal.

286
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 287

Explosionproof Special Operators and Accessories
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9

Reset Button Operators
Description of operations only

Weight
Each
Pounds

XRB

Reset Button - Short

1/2

XRBL

Reset Button - Long

1/2

Used for resetting contactors, relays, etc. in explosionproof and weather-proof
enclosures. Made with 3/4” NPSM threaded stem. Standard operating shaft
length 6” can be cut to length. Special lengths are also available. Use XRBL for
wall thickness greater than 3/4”.

9A–17

XRB / XRBL

Catalog No.

Close-Up Plugs
For Unused Operator Openings
Catalog No.

Description of operations only

Net
Weight

XPP

3/4” NPSM

3/4 oz.

XPP-N4

3/4” NPSM Type 4

3/4 oz.

287
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 288

Explosionproof and Dust-Tight Pilot Lights
CLASS I, GROUPS C & D
Non-Guarded Lens Caps

Cap Color

Weight
Each lbs.

Amber Lens

Black

1/2

Blue Lens

Black

1/2

XLC-C

Clear Lens

Black

1/2

• Black Cap

XLG-C

Green Lens

Black

1/2

• Clear Cap

XLR-C

Red Lens

Black

1/2

XLW-C

White Lens

Black

1/2

XLAC-C

Amber Lens

Clear

1/2

XLBC-C

Blue Lens

Clear

1/2
1/2

All lens caps are black anodized aluminum finish. For color
coding, Adalet will furnish at no additional charge the
following color combinations:

• Amber Cap
• Green Cap
• Blue Cap

9A–18

• Red Cap

Catalog No.

Description

XLA-C
XLB-C

XLCC-C

Clear Lens

Clear

XLGC-C

Green Lens

Clear

1/2

XLRC-C

Red Lens

Clear

1/2

XLWC-C

White Lens

Clear

1/2

XLAA-C

Amber Lens

Amber

1/2

XLBA-C

Blue Lens

Amber

1/2

XLCA-C

Clear Lens

Amber

1/2

XLGA-C

Green Lens

Amber

1/2

XLRA-C

Red Lens

Amber

1/2

XLWA-C

White Lens

Amber

1/2

XLAG-C

Amber Lens

Green

XLBG-C

Blue Lens

Green

1/2

XLCG-C

Clear Lens

Green

1/2

XLGG-C

Green Lens

Green

1/2

XLRG-C

Red Lens

Green

1/2

XLWG-C

White Lens

Green

1/2

XLAB-C

Amber Lens

Blue

1/2

XLBB-C

Blue Lens

Blue

1/2

XLCB-C

Clear Lens

Blue

1/2

XLGB-C

Green Lens

Blue

1/2

XLRB-C

Red Lens

Blue

1/2

XLWB-C

White Lens

Blue

1/2

XLAR-C

Amber Lens

Red

1/2

XLBR-C

Blue Lens

Red

1/2

XLCR-C

Clear Lens

Red

1/2

XLGR-C

Green Lens

Red

1/2

XLRR-C

Red Lens

Red

1/2

XLWR-C

White Lens

Red

1/2

288
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 289

Operator Boots and Hardware

Operator Protective Boots
Molded silicone rubber, protective boots for use with explosion
proof operators in extremely wet-dirty locations. Makes
operators suitable for NEMA 3, 4, 4X, 5, 7, 9, 12, 13
application. Boot and metal collar are an integral assembly
available as a factory adder or a field replacement.
Simple installation requires removal of existing cap and
threading on the replacement.

XBPC

XNP

Catalog No.

XHDPL
XMB

Description

Weight
Each

XBB

Black Push Button Cap

1 oz.

XBG

Green Push Button Cap

1 oz.

XBR

Red Push Button Cap

1 oz.

XBSB

Black Selector Switch Cap

1 oz.

XBSG

Green Selector Switch Cap

1 oz.

XBSR

Red Selector Switch Cap

1 oz.

XBPC

Clear Pilot Light Push Button Cap

1 oz.

9A–19

XBB

XBSB

To order as complete operator add part number as suffix.
XMC

XHPL

XMT

Catalog No.

Description

Weight
Each

XNPWB

Black Blank Legend Plate

1/16

XNPWG

Green Blank Legend Plate

1/16

XNPWR

Red Blank Legend Plate

1/16

Legend plate has foam gasket backing for use with protective
boots for sealing. Engraving 1 line only see Price List.

XHSPL

Push Button and Selector Switch
Components
Operator locking caps and actuator devices can be adapted to
existing explosion proof operators. Simple installation requires
removal of top cap and threading on the replacement unit.

Legend Plates Standard Marking
For Push Button
(BLANK)

SLOW

For Selector switches
RESET

RUN-JOG

OPEN-OFF-CLOSE

START

OPEN

IN

HAND-AUTO

FAST-OFF-SLOW

INCH

CLOSE

OUT

FWD-REV

RUN-AUTO-JOG

STOP
RUN

UP
JOG

FORWARD ON
REVERSE
FAST

OFF
BACK

LEFT

FAST-SLOW

HAND-OFF-AUTO

RIGHT

OPEN-CLOSE FWD-OFF-REV

LOW

UP-DOWN

HIGH

OFF-ON

DOWN

1-OFF-2
UP-OFF-DOWN

Description

Weight
Each

XHDPL

Padlock Device for Dual Push Button

1/4

XHPL

Padlock Device to activate Push Button

1/4

XHSPL

Padlock Device for Selector Switch

1/4

XMB

Red Mushroom Head 2 1/4” Button

1/4

XMC

Maintained Contact Lever for

1/4

Catalog No.

Push Buttons

EMERGENCY STOP
XMT

Catalog No.
XNP

Description
Specify legend

Wobble Stick 2 1/2” Long for NC

1/4

Push Button

Weight
Each

XHPLG

Padlockable Push Button Cover

1/4

(Not Shown)

1/16

Legend plates are anodized aluminum with engraved letters on
black background. Stop has red and start has green
background. Special engraved legend plates can be supplied.

Mushroom button and wobble stick recommended only for
operators with normally closed contact blocks.

289
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 290

Explosionproof Push Button and Selector Switch Components

600 Volts AC Maximum Contact Blocks
for Push Buttons and Selector Switches
Series BT
Catalog

Contact Block

Push Button

BT1A

One Open and

1 N.O.

One Closed

1 N.C.

BT1B

Selector Switch

Weight Ea.
1/10

One Closed and One Open

See
Chart

9A–20

(this is BT1A block

1 N.C.

rotated 180 degrees

1 N.O.

1/10

1 N.O.

1/10

when assembled to
operator)
BT2

Two open

1 N.O.
1 N.C.
BT3

Two closed

1 N.C.

BT4

One open

1 N.O.

BT5

One closed

1 N.C.

BT44

Two open

1 N.C.

Two closed

1 N.O.

1/10
Specify
Cam
and
Contact
Block

1/10
1/10
1/10

1 N.O.

1 N.C.

Contact Sequence Chart
2-Position
Selector
Switches
Cam 1
Contact
Sequence

O = Contact Open
X = Contact Closed
Circuit of Contact Block

Contact
Block
Number

3-Position Selector Switches
Cam 2
Cam 3
Cam 4
Contact
Contact
Contact
Sequence Sequence Sequence

Cam 5
Cam 6
Contact
Contact
Sequence Sequence

Normally Closed (NC)
Normally Open (NO)

BT1A

Circuit A
Circuit B

XO
OX

OX O
OO X

OXX
OOX

XOO
OXO

OXX
X XO

XOO
OXO

Normally Closed (NC)
Normally Open (NO)

BT1B*

Circuit B
Circuit A

XO
OX

XX O
XO X

X XO
X OO

XOX
OX X

OOX
X OO

OOX
OOX

Normally Open(NO)
Normally Open (NO)

BT2

Circuit A
Circuit B

OX
OX

XO X
OO X

X OO
OOX

OX X
OXO

X OO
X XO

OOX
OXO

Normally Closed (NC)
Normally Closed (NC)

BT3

Circuit A
Circuit B

XO
XO

OX O
XX O

OXX
X XO

XOO
XOX

OXX
OOX

XOO
OOX

* This contact block is same as BT1A one N.C. and one N.O. except rotated 180° when
assembled to operator.

Maximum Ampere Rating Control Circuit Contacts Type BT
AC
Volts
Make & Emergency Interrupting Capacity
Normal Load Break
Continuous Current

110
60.
6.
10.

220
30.
3.
10.

440
15.
1.5
10.

550
12.
1.2
10.

120
1.1
1.1
10.

DC
240
0.5
0.5
10.

600
0.2
0.2
10.

290
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 291

Explosionproof and Dust-tight Miniature Operators

CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 4, 7 & 9
Features
• Reduce size of control enclosure requirements in hazardous environments.
• Mount on 1” centers vs. standard operators requiring 2 1/2” centers.
• No special enclosures required; can be installed in most Adalet standard
explosionproof enclosures.

Push Button / Selector Switch Description

9A–21

• 3/8”-16 UNC thread size body.
• Black anodized body, cap, button or knob
• Two lengths available: Long Series
Accommodates up to 1 9/16”
enclosure wall thickness
Short Series
Accommodates up to 13/16”
enclosure wall thickness
• Stainless steel actuator shaft.
• Optional red or green button (Push button Operator only)

Push Buttons
XMOB

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Contact
Configurations

Weight
Each

XMOB-1
XMOB-2

XMOBS-1

SPDT maintained

1 oz.

XMOBS-2

SPDT momentary

1 oz.

XMOB-3*

XMOBS-3*

DPDT maintained

1 oz.

XMOB-4

XMOBS-4

DPDT momentary

1 oz.

* Not UL or CSA Approved

• Solid silver contacts rated 5 amps at 125 VAC, 3 amps at 250 VAC.
• Insulation resistance 1000 megohm minimum.
• Furnished with contact block having 8” wire leads, other lengths available.

Selector Switches

XMOS

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Contact
Configurations

Weight
Each

XMOS-1

XMOSS-1

Single Pole, 12 position

1 oz.

XMOS-2

XMOSS-2

Double Pole, 5 position

1 oz.

XMOS-3

XMOSS-3

Three Pole, 3 position

1 oz.

• Selector switches provided with internal adjustable stop.
• Silver contacts rated 150 m.a. at 30 VAC, NEC CL 2 circuit.
• Insulation resistance 10,000 megohms minimum.
• Furnished with contact block having solder type wire connectors.

291
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:20 AM Page 292

Explosionproof and Dust-tight Miniature Operators
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 4, 7, 9
For Explosionproof Control Enclosures
Indicator Led Light Description

9A–22

• Up to 100,000 hours lamp life.
• Standard 12 VDC furnished. Optional 24 VDC, or 12, 24, 120 VAC available.
• Black anodized body and lens cap.
• 3/8” - 16 UNC thread size body.
• One length-accommodates up to 1 5/16” enclosure wall thickness.
• Furnished with 8” flexible wire leads, other lengths available.

Catalog No.

Description

Weight
Each
1 oz.

XMOLR

Red Indicator Light

XMOLA

Amber Indicator Light

1 oz.

XMOLG

Green Indicator Light

1 oz.

Close-Up Plugs for Unused Operator Openings
Catalog No.

Weight

XMPP

1/2 oz.

Legend Plates Standard Marking

Catalog No.

Description

Weight
Each

XMNP

Specify legend

1/2 oz.

For Push Button

Compliances:
NEC Class I, Groups B, C & D
Class II, Groups E, F & G
UL Standard 698
CSA Standard C22.2 No. 30

For Selector switches

(BLANK)

SLOW

RESET

RUN-JOG

START

OPEN

IN

HAND-AUTO

INCH

CLOSE

OUT

FWD-REV

STOP

UP

LEFT

FAST-SLOW

RUN

JOG

RIGHT

OPEN-CLOSE

FORWARD

ON

LOW

UP-DOWN

REVERSE

OFF

HIGH

OFF-ON

FAST

BACK

• Legend plates are anodized aluminum with engraved letters on black
background.
• Maximum 10 characters, 5/64” high offered as standard.
NOTE: Special engraved legend plates can be supplied.

292
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 293

Explosionproof and Dust-tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
MULTI-HUB BOXES
Designed for general wiring in hazardous locations. For pulling and splicing
conductors. Serves as mounting outlets with use of appropriate fixture
covers.
Available with dome cover for additional splicing room and mounting of
various devices.

Bodies XJAB, XJAD and XJAX 26 thru 46 have two interior mounting
bosses, which can be blind tapped.
Bodies XJAC, XJAL and XJAT 26 thru 46 have four interior mounting
bosses, which can be blind tapped.
All bodies 570 thru 890 have solid back, can be tapped blind.
Conduit
Size (In.)

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJAB-26

1/2

10

9

XJAB-36

3/4

10

10

XJAB-46

1

10

12

XJAB-570

1 1/4

5

25

XJAB-690

1 1/2

4

22

XJAB-890

2

4

23

XJAC-26

1/2

10

9

XJAC-36

3/4

10

10

XJAC-46

1

10

12

XJAC-570

1 1/4

5

26

XJAC-690

1 1/2

4

21

XJAC-890

2

4

23

XJAD-36

3/4

10

9

XJAD-46

1

10

15

XJAL-26

1/2

10

9

XJAL-36

3/4

10

10

XJAL-46

1

10

12

XJAL-570

1 1/4

5

26

XJAL-690

1 1/2

4

21

XJAL-890

2

4

23

10A–1

Catalog
Number

Compliances
• NEC Class I, Groups C, D
Class II, Groups E, F, G

NEMA 4 WATERTIGHT OPTIONAL:
Consult factory for availability and/or
certifications.

• UL Standard 886 - CSA Standard
C22.2 No. 30
293

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 294

Explosionproof and Dust-tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
MULTI-HUB BOXES

XJAL
(No bottom hub)

Catalog
Number

Conduit
Size (In.)

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJAT-26

1/2

10

10

XJAT-36

3/4

10

10

XJAT-46

1

10

13

XJAT-570

1 1/4

5

27

XJAT-690

1 1/2

4

21

XJAT-890

2

4

23

XJAX-26

1/2

10

12

XJAX-36

3/4

10

14

XJAX-46

1

10

15

XJAX-570

1 1/4

5

27

XJAX-690

1 1/2

4

21

XJAX890

2

4

23

10A–2
XJAT
(No bottom hub)

XJAX
(No bottom hub)

Compliances
• NEC Class I, Groups C, D
Class II, Groups E, F, G

NEMA 4 WATERTIGHT OPTIONAL:
Consult factory for availability and/or
certifications.

• UL Standard 886 - CSA Standard
C22.2 No. 30

294
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 295

Explosionproof and Dust-tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
MULTI-HUB BOXES
BLANK COVERS
Catalog
Number

Description

St. Pkg.

Std. Pkg.
Weight Lbs.

XJA6

For 1/2" – 3/4" – 1" Bodies

10

5

XJA8

For 1 1/4" – 1 1/2" – 2" Bodies

5

11

SEALING COVERS
XJA6

Catalog
Number

Description

St. Pkg.

Std. Pkg.
Weight Lbs.

XJA6S

For 1/2" – 3/4" – 1" Bodies

10

7

10A–3

Entire body must be filled with sealing compound. NEC
prohibits splices and taps in sealing fittings.
DOME COVERS
Catalog
Number

XJA6S

Description

St. Pkg.

Std. Pkg.
Weight Lbs.

XJADC

For 1/2" – 3/4" – 1" Bodies
Inside Depth 2 3/8"

10

9

XJAD4

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 4 1/8"

1

5

XJAD6

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 6"

1

6

XJAD10

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 10"

1

8 1/2

XJAD13

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 13"

1

9 1/2

XJAO

O-Ring For NEMA 4 watertight
For 1/2" – 3/8" – 1" Bodies

1

—

XJTO

O-Ring for NEMA 4 watertight
For 1 1/4" – 1 1/2" – 2" Bodies

1

—

XJADC

295
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 296

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS
CLASS I, GROUPS B*, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9

Sealing Fittings are required in Hazardous Locations and are used to
isolate arc-producing devices in conduit and wiring systems, and to
prevent the passage of explosive pressures from one area to another.
FOR HORIZONTAL AND VERTICAL MOUNTING - Type XYB and XYBM
are suitable for either horizontal or vertical mounting and are provided
with threaded plugged openings into which fiber and cement can be
placed to form effective seal. XYB has female ends for conduit entrance.
The XYBM has female ends with a removable threaded nipple.
*1/2”, 3/4”, 1” sizes Class I, Group B, C, D, Class II, E, F, G.
XYB-XYBM

1 1/4”, 1 1/2”, 2”, 2 1/2”, 3”, 3 1/2”, 4” sizes Class I, Group C, D
Class II, E, F, G

CSA Certified LR27991
UL Listed E10493

10A–4

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Female-Female

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Male-Female

XYB-2

1/2

1

1/8

5

2.1

XYBM-2

1/2

1

1/8

5

2.2

XYB-3

3/4

2

1/4

5

2.6

XYBM-3

3/4

2

1/4

5

2.7

XYB-4

1

3

1/4

5

3.7

XYBM-4

1

3

1/4

5

3.8

XYB-5

1-1/4

6

3/8

2

2.5

XYBM-5

1-1/4

6

3/8

2

2.6

XYB-6

1-1/2

9

1/2

2

3.2

XYBM-6

1-1/2

9

1/2

2

3.4

XYB-8

2

18

3/4

2

5.6

XYBM-8

2

18

3/4

2

5.9

XYB-10

2-1/2

23

1-1/2

2

6.2

XYBM-10

2-1/2

23

1-1/2

2

6.8

XYB-12

3

48

3-1/8

1

6.0

XYBM-12

3

48

3-1/8

1

6.3

XYB-14

3-1/2

70

4-1/2

1

6.8

XYBM-14

3-1/2

70

4-1/2

1

7.3

XYB-16

4

90

6

1

8.3

XYBM-16

4

90

6

1

8.8

Nominal Dimensions (Inches)
Conduit
Size

(XYBM Series Only)
D

C

Turn
Radius R

A

B

1/2

3-19/32

1-13/16

5/8

11/16

1-3/16

3/4

3-25/32

2-1/16

3/4

15/16

1-5/16

1

4-3/8

2-5/16

7/8

15/16

1-7/16

1-1/4

5-5/32

2-13/16

1-1/16

1-1/16

1-3/4

1-1/2

5-11/16

3-3/16

1-3/16

1-3/16

2

2

6-13/16

3-7/8

1-1/2

1-7/16

2-3/8

2-1/2

7-1/2

4-1/2

1-7/8

1-5/8

2-11/16

3

9-9/16

5-1/2

2-3/16

1-7/8

3-5/16

3-1/2

9-1/2

6-1/6

2-3/8

2

3-11/16

4

9-9/16

6-1/2

2-5/8

2-1/8

3-7/8

Compliances
• NEC Class I, Groups B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard
C22.2 No. 30

296
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 297

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS
CLASS I, GROUPS B*, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Sealing Fittings are used for the same application as the standard
Adalet sealing fitting but allow up to 40% wire fill in the fitting.
*1/2”, 3/4” sizes Class I, Group B, C, D, Class II, E, F, G.
1”, 1-1/4”, 1-1/2”, 2”, 2-1/2”, 3” sizes Class I, Group C, D,
Class II, E, F, G.

XYB-XYBM

CSA Certified LR27991

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Male-Female

Female-Female
XYB-34

1/2

2

1/4

5

2.6

XYBM-34

1/2

2

1/4

5

2.7

XYB-44

3/4

3

1/4

5

3.7

XYBM-44

3/4

3

1/4

5

3.8

XYB-54

1

6

3/8

2

2.5

XYBM-54

1

6

3/8

2

2.6

XYB-84

1-1/4

18

3/4

2

5.6

XYBM-84

1-1/4

18

3/4

2

5.9

XYB-104

1-1/2

23

1-1/2

2

6.2

XYBM-104

1-1/2

23

1-1/2

2

6.8

XYB-124

2

48

3-1/8

1

6.0

XYBM-124

2

48

3-1/8

1

6.3

XYB-144

2-1/2

70

4-1/2

1

6.8

XYBM-144

2-1/2

70

4-1/2

1

7.3

XYB-164

3

90

6

1

8.3

XYBM-164

3

90

6

1

8.8

Nominal Dimensions (Inches)
Conduit
Size

A

B

C

(XYBM Series Only)
D

Turn
Radius R

1/2

3-25/32

2-1/16

3/4

15/16

1-5/16

3/4

4-3/8

2-5/16

7/8

15/16

1-7/16

1

5-5/32

2-13/16

1-1/16

1-1/16

1-3/4

1-1/4

6-13/16

3-7/8

1-1/2

1-7/16

2-3/8

1-1/2

7-1/2

4-1/2

1-7/8

1-5/8

2-11/16

2

9-9/16

5-1/2

2-3/16

1-7/8

3-5/16

2-1/2

9-1/2

6-1/16

2-3/8

2

3-11/16

3

9-9/16

6-1/2

2-5/8

2-1/8

3-7/8

Compliances
• NEC Class I, Groups B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard C22.2 No. 30
297
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

10A–5

UL Listed E10493

15599 Sec.10 12/9/01 11:21 AM Page 298

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Adalet Sealing Fittings are used to isolate arc-producing devices from wiring
systems and to prevent the spread of explosive gases.

XY 2-3-4

XYM 2-3-4

FOR VERTICAL MOUNTING
Types XY and XYM Fittings are for vertical mounting, and are provided with
threaded plugged openings into which the sealing cement is poured. Sizes
1-1/4” x 1-1/2” have large plugged openings in the lower hub to facilitate
packing fiber around the wires to form a dam. Type XYM’s have removable
threaded nipples. The two hubs are tapped simultaneously to assure
alignment of the conduits, especially important to equipment manufacturers
using short runs of conduit.
FOR HORIZONTAL & VERTICAL MOUNTING
Type XYC Fittings are for horizontal mounting only, with the cover opening
in an upright position. XYCS fittings are for vertical or horizontal mounting,
with removable threaded covers which can be turned to the desired
position for pouring in the sealing cement. The covers are interchangeable.
The male-to-female types have removable threaded nipple.

10A–6

Catalog Number

XY 5-6

XYC

XYM 5-6

XYCM

Ounces
Required per Fitting

Standard Package

Female/
Female

Male/
Female

Conduit
Size
(In.)

XY2

XYM2

1/2

1

1/8

25

XY3

XYM3

3/4

1

1/4

25

10

XY4

XYM4

1

2

1/4

25

12-1/2

XY5

XYM5

1-1/4

4

3/8

10

7-1/2

XY6

XYM6

1-1/2

5

1/2

10

10

XYC2

XYC2M

1/2

2

1/8

25

13

XYC3

XYC3M

3/4

2

1/4

25

13

XYC4

XYCM4

1

4-1/2

1/4

25

15

XYC5

XYC5M

1-1/4

8-1/2

3/8

10

10

XYC6

XYC6M

1-1/2

11-1/2

1/2

10

11
12

Sealing
Cement

Packing
Fiber

Qty

Weight
Lbs.
10

XYC8

XYC8M

2

13-1/2

3/4

10

XYC10

XYC10M

2-1/2

15

1-1/2

1

2

XYC12

XYC12M

3

31-1/2

3-1/8

1

3

XYC14

XYC14M

3-1/2

42-1/2

4-1/2

1

4

XYC16

XYC16M

4

51

6

1

5

XYC2S

XYC2SM

1/2

2

1/8

25

13

XYC3S

XYC3SM

3/4

2

1/4

25

13

XYC4S

XYC4SM

1

3

1/4

25

15

XYC5S

XYC5SM

1-1/4

6-1/2

3/8

10

10

XYC6S

XYC6SM

1-1/2

10

1/2

10

11

XYC8S

XYC8SM

2

12-1/2

3/4

10

12

XYC10S

XYC10SM

2-1/2

13-1/2

1-1/2

1

2

XYC12S

XYC12SM

3

29-1/2

3-1/8

1

3

Compliances

XYC14S

XYC14SM

3-1/2

40

4-1/2

1

4

• NEC Class I, Group D Class II, Groups E, F, G
• UL Standard 886 - CSA Standard C22.2 No. 30

XYC16S

XYC16SM

4

48-1/2

6

1

5

XYCS

XYCSM

CSA Certified LR27991
UL Listed E10493

298
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 299

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING
FITTINGS CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9

Adalet 40% Fill Sealing Fittings are used
for the same applications as the standard
Adalet Sealing Fittings, but allow up to
40% wire fill in the fitting.

XY 54

XYC 34XYC 164

XYC 34SXYC 164S

XYM 34, 44

Catalog Number

XYM 54

XYC 34MXYC 164M

Ounces
Required per Fitting

Standard Package

Female/
Female

Male/
Female

Conduit
Size
(In.)

XY34

XYM34

1/2

1

1/4

25

10

XY44

XYM44

3/4

2

1/4

25

12-1/2
7-1/2

Sealing
Cement

Packing
Fiber

Qty

Weight
Lbs.

XY54

XYM54

1

4

3/8

10

XYC34

XYC34M

1/2

2

1/4

25

13

XYC44

XYC44M

3/4

4-1/2

1/4

25

15

XYC54

XYC54M

1

8-1/2

3/8

10

10

XYC84

XYC84M

1-1/4

13-1/2

3/4

10

12

XYC104

XYC104M

1-1/2

15

1-1/2

1

2

XYC124

XYC124M

2

31-1/2

3-1/8

1

3

XYC144

XYC144M

2-1/2

42-1/2

4-1/2

1

4

XYC164

XYC164M

3

51

6

1

5

XYC34S

XYC34SM

1/2

2

1/4

25

13

XYC44S

XYC44SM

3/4

3

1/4

25

15

XYC54S

XYC54SM

1

6-1/2

3/8

10

10

XYC84S

XYC84SM

1-1/4

12-1/2

3/4

10

12

XYC104S

XYC104SM

1-1/2

13-1/2

1-1/2

1

2

XYC124S

XYC124SM

2

29-1/2

3-1/8

1

3

XYC144S

XYC144SM

2-1/2

40

4-1/2

1

4

XYC164S

XYC164SM

3

48-1/2

6

1

5

XYC 34SMXYC 164SM

Compliances
• NEC Class I, Group D
Class II, Groups E, F, G
CSA Certified LR27991

• UL Standard 886 - CSA Standard
C22.2 No. 30

UL Listed E10493

299
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

10A–7

XY 34, 44

15599 Sec.10 12/9/01 11:22 AM Page 300

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Dimensions (In.)
Catalog Number

10A–8
CSA Certified LR27991
UL Listed E10493

R = Turning

Nominal Dimensions, (In.)

Radius (Inches)

Female/
Female

Male/
Female

Conduit
Size

A

B

C

D

XY2

XYM2

1/2

3-1/16

2-7/16

3/4

11/16

1-13/16

XY3

XYM3

3/4

3-1/16

2-7/16

3/4

1

1-13/16

XY4

XYM4

1

3-3/4

2-15/16

15/16

15/16

2-1/8

XY5

XYM5

1-1/4

4-15/16

3-3/16

1-3/16

1-1/8

2-1/8

E

Plain
Cover

Sealing
Cover

XY6

XYM6

1-1/2

4-7/8

3-7/16

1-5/16

1-5/16

XYC2

XYC2M

1/2

3-1/16

2-9/16

2-1/6

5/8

13/16

1-7/8

2-11/16

XYC2S

XYC2SM
3/4

3-1/6

2-9/16

2-1/16

15/16

13/16

1-7/8

2-11/16

1

3-11/16

2-11/16

2-3/8

15/16

1

2-1/8

3-1/16

1-1/4

4-1/2

3-3/16

3-3/8

1-1/16

7/8

2-11/16

3-1/16

1-1/2

4-1/2

3-7/16

3-3/8

1-1/8

7/8

2-11/16

3-1/16

2

4-11/16

4

3-3/8

1-3/8

7/8

3

3-5/16

2-1/2

5-5/16

4-5/8

3-3/8

1-5/8

7/8

3-1/4

3-3/4

3

6-7/16

5-7/16

3-15/16

1-3/4

1-3/8

4

4-5/8

3-1/2

6-9/16

6-3/8

4-3/4

1-5/8

1-5/16

4-5/8

5

4

6-15/16

6-13/16

4-3/4

2

1-5/16

4-3/4

5-3/8

XYC3

XYC3M

XYC3S

XYC3SM

XYC4

XYC4M

XYC4

XYC4SM

XYC5

XYC5M

XYC5S

XYC5SM

XYC6

XYC6M

XYC6S

XYC6SM

XYC8

XYC8M

XYC8S

XYC8SM

XYC10

XYC10M

XYC10S

XYC10SM

XYC12

XYC12M

XYC12S

XYC12SM

XYC14

XYC14M

XYC14S

XYC14SM

XYC16

XYC16M

No
Cover

2-1/4

ADACO SEALING CEMENT AND ADACO PACKING FIBER
CLASS I, GROUPS B, C & D; CLASS II,
GROUPS E, F & G; NEMA 7 & NEMA 9

XSC

XAF

Catalog No.

Description

XSC-8

ADACO No. 1

Net Weight
8 oz.

XSC-16

Sealing

16 oz.

XSC-160

Cement

10 lbs.
1-1/2 oz.

XAF-6

ADACO

XAF-24

Packing

6 oz.

XAF-64

Fiber

1 lb.

ADACO SEALING CEMENT is the easiest-to-use sealing cement on the market. The
powder is contained in a polyethylene bag within an outer container. To mix, remove
the bag of powder, fill the outside container with water up to the marked “water line”
and pour in the powder. Simple...no guesswork about how much water to use. The
mixing container is right there...and clean. The largest unit package offered contains
one pound of powder. The XSC-160 (10-pound quantity) consists of 10, one-pound
packages (at the ten-pound price) so that every mix is correct. This cement has been
especially prepared for use in Adalet Sealing Fittings. It is not an insulating compound,
and is not affected by gasoline, alcohol, benzol, oils, acetone or lacquer solvents.
ADACO PACKING FIBER is used with Adaco Sealing Cement for plugging conduit
openings in fittings. Alumina Silica based long fiber non-asbestos for use as a packing
at the hubs of sealing units to prevent the Sealing Cement in the liquid state from
entering the conduit lines. The Fiber is tamped between the wires and the hub before
the Sealing Cement is poured into the fitting.

300
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 301

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9

R = Turning

Nominal Dimensions, (In.)

Radius (Inches)

Female/
Female

Male/
Female

Conduit
Size

A

XY34

XYM34

1/2

3-1/6

2-7/16

3/4

1

XY44

XYM44

3/4

3-3/4

2-15/16

15/16

15/16

3-1/8

XY54

XYM54

1

4-15/16

3-3/16

1-3/16

1-1/8

2-1/8

XYC34

XYC34M

1/2

3-1/6

2-9/16

2-1/16

15/16

13/16

1-7/8

2-11/16

XYC34S

XYC34SM
3/4

3-11/16

2-11/16

2-3/8

15/16

1

2-1/8

3-1/16

1

4-1/2

3-3/16

3-3/8

1-1/16

7/8

2-11/16

3-1/16

1-1/4

4-11/16

4

3-3/8

1-3/8

7/8

3

3-5/16

1-1/2

5-5/16

4-5/8

3-3/8

1-5/8

7/8

3-1/4

3-3/4

2

6-7/16

5-7/16

3-15/16

1-3/4

1-3/8

4

4-5/8

2-1/2

6-9/16

6-3/8

4-3/4

1-5/8

1-5/16

4-5/8

5

3

6-15/16

6-13/16

4-3/4

2

1-5/16

4-3/4

5-3/8

XYC44

XYC44M

XYC4S

XYC44SM

XYC54

XYC54M

XYC54S

XYC54SM

XYC84

XYC84M

XYC84S

XYC84SM

XYC104

XYC104M

XYC104S

XYC104SM

XYC124

XYC124M

XYC124S

XYC124SM

XYC144

XYC144M

XYC144S

XYC144SM

XYC164

XYC164M

XYC164S

XYC164SM

B

C

D

10A–9

Dimensions (In.)
Catalog Number

E

Plain
Cover

Sealing
Cover

No
Cover
1-13/16

301
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 302

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT
SHORT RADIUS PULL ELBOWS
CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & 9
This versatile and inexpensive explosion-proof fitting with a threaded
cover will easily and compactly handle 90° conduit runs. FL series have
two female entrances. MFL series has one female entrance and one
removable threaded nipple.
Nominal Dimensions Inches

FL

MFL

10A–10

Compliances
• NEC Class I, Group D
Class II, Groups E, F, G

Standard Package

Catalog
Number

Conduit
Size (In.)

FL92

1/2

2-5/8

2-1/8

1-3/8

25

8

FL93

3/4

2-13/16

2-1/8

1-1/2

25

10-1/2

A

B

C

Quantity

Weight
Pounds

FL94

1

3-1/4

2-7/16

1-7/8

25

11

FL95

1-1/4

3-3/4

3-1/2

2-1/4

25

24
30

*FL96

1-1/2

4-5/8

4-3/16

2-5/8

25

MFL92

1/2

2-5/8

2-1/8

1-3/8

25

9

MFL93

3/4

2-13/16

2-1/8

1-1/2

25

12

MFL94

1

3-1/4

2-7/16

1-7/8

25

13

MFL95

1-1/4

3-3/4

3-1/2

2-1/4

25

26

*MFL96

1-1/2

4-5/8

4-3/16

2-5/8

25

34

* Fitting not UL Listed or CSA Certified

• UL Standard 886 - CSA Standard C22.2 No. 30

CSA Certified LR27991
UL Listed E10493

EXPLOSIONPROOF AND DUST-TIGHT REMOVABLE PLUGS
CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G;
NEMA 7 & NEMA 9
Tapered thread close-up plugs for explosionproof conduit entrances. Provides
5 full threads of engagement. Made of aluminum alloy, these plugs have
screw-driver slots and fit practically flush when installed.

Standard Package

OX

Weight
Pounds

Standard Package

Catalog
Number

Conduit
Size (In.)

Catalog
Number

Conduit
Size (In.)

Qty

OX2

1/2

250

6-3/4

OX8

2

50

12

OX3

3/4

250

10-1/4

OX10

2-1/2

50

20-1/2

Qty

Weight
Pounds

OX4

1

150

9

OX12

3

50

30

OX5

1-1/4

100

12

OX14

3-1/2

50

40

OX6

1-1/2

100

14-1/2

OX16

4

50

52

302
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 303

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT CONDUIT UNIONS
CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Explosionproof unions for use in conduit piping systems for ease of
installation and removal of fittings, boxes and equipment enclosures in
hazardous atmosphere areas. Parts are steel, cadmium plated for corrosion
protection. Style XU has two female NPT threads. Style XUM has two
female NPT threads and one plated threaded nipple.

Standard Package
Conduit
Size

Qty

Weight
Pounds

XU2

1/2”

XU3

3/4”

Female-Female

50

19

Female-Female

50

XU4

1”

21

Female-Female

25

13-1/2

XUM2
XUM3

1/2”

Female-Male

50

22

3/4”

Female-Male

50

XUM4

26

1”

Female-Male

25

16-1/2

10A–11

XU

Catalog
Number

DIMENSIONS
Conduit
Size

A

B

Series

1/2”

1-3/4”

1-1/2”

XU

3/4”

1-3/4”

1-3/4”

1”

1-15/16”

2”

Series

1/2”

2-9/16”

1-1/2”

XUM

3/4”

2-3/4”

1-3/4”

1”

3”

2”

XUM

Compliance
• NEC Class I, Groups A, B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard C22.2 No.30

CSA Certified LR27991
UL Listed E10493

303
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 304

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT FLEXIBLE COUPLINGS
*CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Application: XFC couplings are for use in Hazardous Atmospheres where a flexible connection
is required for motor and equipment installation where movement and vibration are present.
Also for difficult bends and connections.
Material: Brass and bronze end fittings. Bronze wire flexible braid covering over flexible bronze
core with insulating liner. INCLUDES TWO REMOVABLE ZINC CLEAR COATED NIPPLES.
NOTE: For stainless steel in 1/2" and 3/4" sizes add SS suffix (XFCSS-) nipples not included.
Nominal Dimensions (inches)

10A–12

Catalog
Number

Conduit
Size

Flex
Length

Weight
Pounds

Catalog
Number

Conduit
Size

Flex
Length

Weight
Pounds

XFC-24

1/2

4

1-3/4

XFC-410

1

10

2-5/8

XFC-26

1/2

6

2

XFC-412

1

12

2-3/4

XFC-28

1/2

8

2-1/2

XFC-415

1

15

3

XFC-210

1/2

10

2-3/8

XFC-418

1

18

3-1/4

XFC-212

1/2

12

2-1/2

XFC-421

1

21

3-1/2

XFC-215

1/2

15

2-5/8

XFC-424

1

24

3-3/4

XFC-218

1/2

18

3

XFC-427

1

27

4-1/8

XFC-221

1/2

21

3-1/8

XFC-430

1

30

4-1/2

XFC-224

1/2

24

3-1/4

XFC-433

1

33

4-7/8

XFC-227

1/2

27

3-3/8

XFC-436

1

36

5-1/4

XFC-230

1/2

30

3-1/2

XFC-512

1-1/4

12

6-1/2

XFC-233

1/2

33

3-3/4

XFC-515

1/14

15

7

XFC-236

1/2

36

4

XFC-518

1-1/4

18

7-1/2

XFC-34

3/4

4

2

XFC-521

1-1/4

21

8-1/4

XFC-36

3/4

6

2-1/4

XFC-524

1-1/4

24

8-3/4

XFC-38

3/4

8

2-3/8

XFC-527

1-1/4

27

9-1/2

XFC-310

3/4

10

2-1/2

XFC-530

1-1/4

30

10-1/4

XFC-312

3/4

12

2-5/8

XFC-533

1-1/4

33

10-3/4

XFC-315

3/4

15

3

XFC-536

1-1/4

36

11-1/4

XFC-318

3/4

18

3-1/8

XFC-612

1-1/2

12

8-1/4

XFC-321

3/4

21

3-1/4

XFC-615

1-1/2

15

9

XFC-324

3/4

24

3-3/8

XFC-618

1-1/2

18

10

XFC-327

3/4

27

3-1/2

XFC-621

1-1/2

21

11

XFC-330

3/4

30

3-3/4

XFC-624

1-1/2

24

12

XFC-333

3/4

33

4

XFC-627

1-1/2

27

13

XFC-336

3/4

36

4-1/2

XFC-630

1-1/2

30

14

XFC-46

1

6

2-1/4

XFC-633

1-1/2

33

15

XFC-48

1

8

2-1/2

XFC-636

1-1/2

36

16

CSA Certified LR27991

Nominal Dimensions (inches)
Catalog
Number

Series

Conduit
Size

Min. Radius
Bend

Classification*

A

B

C

1/2

Class I & II

1-11/16

2-5/16

1-7/16

12

3/4

Group A, B, C, D, E, F & G

1-3/4

2-5/8

1-7/8

14

14

1

XFC

Class I & II
Group C, D, E, F & G

2

3

2-5/16

1-1/4

Class I & II

2-1/8

3-3/8

2-3/4

16

1-1/2

Group D, E, F & G

2-1/2

3-7/8

3-5/16

16

UL Listed E10493
Compliances
• NEC Class I, Groups A, B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard
C22.2 No. 30

304
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 305

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT FLEXIBLE COUPLINGS
*CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Application: XFCU couplings are for use in Hazardous Atmospheres where a flexible
connection is required for motor and equipment installation where movement and vibration
are present. Also for difficult bends and connections.
Material: Brass and bronze end fittings. Bronze wire flexible braid covering over flexible bronze
core with insulating liner. INCLUDES ONE REMOVABLE ZINC CLEAR COATED NIPPLE ON
ONE SIDE AND ONE UNION FITTING ON THE OTHER SIDE.
Nominal Dimensions (inches)

CSA Certified LR27991

Conduit
Size

Flex
Length

XFCU-24

1/2

4

XFCU-26

1/2

6

Weight
Pounds

Catalog
Number

Conduit
Size

Flex
Length

Weight
Pounds

2

XFCU-410

1

10

3

2-1/4

XFCU-412

1

12

3-1/8

XFCU-28

1/2

8

2-1/2

XFCU-415

1

15

3-3/8

XFCU-210

1/2

10

2-5/8

XFCU-418

1

18

3-5/8

XFCU-212

1/2

12

2-3/4

XFCU-421

1

21

3-7/8

XFCU-215

1/2

15

3-1/8

XFCU-424

1

24

4-1/8

XFCU-218

1/2

18

3-1/4

XFCU-427

1

27

4-1/2

XFCU-221

1/2

21

3-3/8

XFCU-430

1

30

4-5/8

XFCU-224

1/2

24

3-1/2

XFCU-433

1

33

5-1/8

XFCU-227

1/2

27

3-5/8

XFCU-436

1

36

5-1/2

XFCU-230

1/2

30

3-3/4

XFCU-233

1/2

33

4

XFCU-236

1/2

36

4-1/4

XFCU-34

3/4

4

2-1/4

XFCU-36

3/4

6

2-1/2

XFCU-38

3/4

8

2-5/8

XFCU-310

3/4

10

2-3/4

XFCU-312

3/4

12

3-1/8

XFCU-315

3/4

15

3-1/4

XFCU-318

3/4

18

3-3/8

XFCU-321

3/4

21

3-1/2

XFCU-324

3/4

24

3-5/8

XFCU-327

3/4

27

3-3/4

XFCU-330

3/4

30

4

XFCU-333

3/4

33

4-1/4

XFCU-336

3/4

36

4-3/4

XFCU-46

1

6

2-5/8

XFCU-48

1

8

2-7/8

10A–13

Catalog
Number

UL Listed E10493
Nominal Dimensions (inches)
Catalog
Number
Series

Conduit
Size

Classification*

A

B

C

D

E

1/2

Class I & II

1-11/16

2-5/16

1-7/16

2-7/16

1-1/2

12

3/4

Group A,B,C,D,E,F & G

1-3/4

2-5/8

1-7/8

2-1/2

1-3/4

14

1

Group C,D,E,F & G

2

3

2-5/16

2-13/16

2

14

XFCU

Min. Radius
Bend

Class I & II

Compliances
• NEC Class I, Groups A, B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA
Standard C22.2 No. 30

305
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 306

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT
COMBINATION BREATHER/DRAIN
CLASS I, GROUPS C & D;
CLASS II, GROUPS F & G; NEMA 7 & NEMA 9

Stainless steel combination breather drain. Install in top of enclosures as
breather. Install in bottom of enclosure as drain.

A

Nominal Dimensions (inches)
Catalog Number

Thread

A

B

XDB2

1/2 NPT

1-5/8

7/8 hex

B

Compliances
• NEC Class I, Groups C, D Class II, Groups E, F, G - Class III

XDB2

• UL Standard 886 - CSA Standard C22.2 No. 30

10A–14

CSA Certified LR27991
UL Listed E10493

EXPLOSIONPROOF AND DUST-TIGHT
COMBINATION BREATHER/DRAIN
CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Nominal Dimensions (inches)
C

A

XDBH2

Catalog Number

Thread

A

B

C

XDBH2

1/2 NPT

2-7/16

7/8 HEX

1-1/4

Flow Rate:
.01 CFM air
.5 cc/minute water

Certifications
• Class I, Groups A, B, C and D Class II, Groups E, F & G - Class III
UL and CSA
UL Standard 886 - CSA Standard C22.2 No. 30

CSA Certified LR27991

• CENELEC EExd IIB DEMKO 00E.004127U

UL Listed E10493
306
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 307

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF FLAME ARRESTOR FITTING
CLASS I, GROUPS B*, C & D NEMA 7

APPLICATION: Provides thru-wall connections of tubing systems for
electro/pneumatic and gas analysis devices installed within Adalet’s
explosion proof enclosures.
The flame arrestor fitting is designed to prevent flame propagation thru
tubing systems with minimum flow restrictions of control pressures.
Typical XFA2

MATERIAL: Stainless steel

Catalog Number

Description

Weight

XFA2

1/2” NPT

4 oz.

XFAX2

1/2” NPT

4 oz.

10A–15

Typical XFAX2

Exterior enclosure wall counter boring may be required to maintain 1/2”
enclosure wall thickness for ease of field connections.

XFA2
Approximate Control Restrictions

*XFAX2
Approximate Control Restrictions

* 0.5 PSI drop at 20 CFH airflow
* 1.3 PSI drop at 34 CFH airflow

1 PSI drop at 18 CFH airflow
5 PSI drop at 53 CFH airflow

*
*
*
*

UL and CSA Class I, Groups B, C & D
CENELEC EExd Group IIB
DEMKO 00E.0041270

NEC Class I, Groups C & D
UL Recognized Component
CSA Certified Component
CENELEC EExd Group IIB

CSA Certified LR27991
UL Recognized E10493
307

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 308

Fittings and Accessories
SALI INSULATING BUSHINGS
(SUPERIOR ADALET LAMINATED INSULATION)
Specifications:
• 11,000 psi tensile
• 17,000 flexural
• 450v/mil dielectric
• Heat resistance - 150° C, continuous
• Moisture absorption - 1/2 of 1%
• Listed by Underwriters Laboratories
for your quality assurance.
• Sali bushings have been repeatedly
proved in a wide variety of
applications over a 25 year period.

Sali bushings are machined from paper
laminated phenolic material and comply with
NEMA-X phenolic material specifications.

TYPE PE-FEMALE-DEEP-THREADED
Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PE-2

1/2

50

1-1/2

5/8

1-1/8

5/8

PE-3

3/4

50

2

13/16

1-5/16

5/8

I.D.

Nominal Dimensions (Inches)
O.D.
Height

10A–16

E10016
LISTED

Recommended for rigid conduit or
in combination with male type
PEM when maximum thread
engagement is required.

PE-4

1

50

3-1/2

1

1-5/8

25/32

PE-5

1-1/4

25

4-1/2

1-3/8

2

25/32

PE-6

1-1/2

25

5-1/2

1-5/8

2-1/4

25/32

PE-8

2

10

7-1/2

2

2-3/4

25/32

PE-10

2-1/2

5

12

2-7/16

3-1/4

1

PE-12

3

5

16

3

3-7/8

1-1/16

PE-14

3-1/2

5

19

3-1/2

4-3/8

1-1/16

PE-16

4

2

24

4

5

1-1/16

TYPE PES-FEMALE-SHALLOW-THREADED

E10016
LISTED

Designed for general use on rigid
conduit, connectors, and similar
installations where the additional
mechanical strength of the deep
type bushings is not needed.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PES-2

1/2

50

1-1/2

5/8

1-1/8

1/2

PES-3

3/4

50

2

13/16

1-5/16

1/2

I.D.

Nominal Dimensions (Inches)
O.D.
Height

PES-4

1

50

3

1

1-5/8

5/8

PES-5

1-1/4

25

4

1-3/8

2

5/8

PES-6

1-1/2

25

4-1/2

1-5/8

2-1/4

5/8

PES-8

2

10

7

2

2-3/4

5/8

PES-10

21/2

5

11

2-7/16

3-1/4

13/16

PES-12

3

5

14

3

3-7/8

7/8

PES-14

3-1/2

5

16-1/2

3-1/2

4-3/8

7/8

PES-16

4

2

25

4

5

7/8

308
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 309

Fittings and Accessories
TYPE PET-THREADLESS-FOR RIGID
CONDUIT-FEMALE-SET SCREW THREADLESS

For threadless rigid
conduit on all free conduit
terminals such as
terminating behind or
within switchboards,
switchgear, etc.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PET-2

1/2

50

1-1/2

5/8

1-1/8

5/8

7/8

PET-3

3/4

50

2

13/16

1-5/16

5/8

1-1/16

I.D. 1

Nominal Dimensions (Inches)
O.D.
Height

I.D. 2

PET-4

1

50

3-1/2

1

1-5/8

25/32

1-11/32

PET-5

1-1/4

25

4-1/2

1-3/8

2

25/32

1-11/16

PET-6

1-1/2

25

5-1/2

1-5/8

2-1/4

25/32

1-15/16

PET-8

2

10

7-1/2

2

2-3/4

25/32

2-13/32

PET-10

2-1/2

5

12

2-7/16

3-1/4

1

2-29/32
3-17/32

PET-12

3

5

14

3

3-7/8

1-1/16

PET-14

3-1/2

5

17

3-1/2

4-3/8

1-1/16

4-1/32

PET-16

4

2

25

4

5

1-1/16

4-17/32

E10016
LISTED

E10016
LISTED

For use directly on thin
wall conduit.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

SPE-2

1/2

50

1-3/4

5/8

1-1/8

5/8

23/32

SPE-3

3/4

50

2-1/4

13/16

1-5/16

5/8

15/16

I.D. 1

Nominal Dimensions (Inches)
O.D.
Height

I.D. 2

SPE-4

1

50

3-3/4

1

1-5/8

25/32

1-3/16

SPE-5

1-1/4

25

5-1/4

1-3/8

2

25/32

1-17/32

SPE-6

1-1/2

25

6

1-5/8

2-1/4

25/32

1-25/32

SPE-8

2

10

8-1/4

2

2-3/4

25/32

2-7/32

For EMT sizes 2-1/2 thru 4” use type PET.

TYPE PEM

A high strength resilient male
bushing recommended to
protect wires passing through
steel cabinet walls, metal
partitions and similar
applications. For additional
strength it is recommended
this bushing be secured with
type PE deep threaded
female bushing.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PEM-2

1/2

50

1

5/8

1-1/8

5/8

PEM-3

3/4

50

1-1/2

13/16

1-5/16

5/8
25/32

I.D.

Nominal Dimensions (Inches)
O.D.
Height

PEM-4

1

50

2-1/2

1

1-5/8

PEM-5

1-1/4

25

3

1-3/8

2

25/32

PEM-6

1-1/2

25

4

1-5/8

2-1/4

25/32

PEM-8

2

10

6

2

2-3/4

25/32

PEM-10

2-1/2

5

10

2-7/16

3-1/4

1-1/16

PEM-12

3

5

14

3

3-7/8

1-1/16

PEM-14

3-1/2

5

16-1/2

3-1/2

4-3/8

1-1/16

PEM-16

4

2

21

4

5

1-1/16

E10089
309

LISTED

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

10A–17

TYPE SPE-THREADLESS-FOR EMT-FEMALE-SET SCREW

15599 Sec.10 12/9/01 11:22 AM Page 310

Fittings and Accessories

TYPE PEML WITH LOCKNUT

A high strength resilient male
bushing recommended to protect
wires passing through metal walls,
partitions and similar applications.
Furnished with metallic locknuts.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PEML-2

1/2

50

2-1/2

5/8

1-1/8

5/8

PEML-3

3/4

50

3-1/2

13/16

1-5/16

5/8

I.D.

Nominal Dimensions (Inches)
O.D.
Height

PEML-4

1

50

6

1

1-5/8

25/32

PEML-5

1-1/4

25

6-1/2

1-3/8

2

25/32

PEML-6

1-1/2

25

9

1-5/8

2-1/4

25/32

PEML-8

2

10

11

2

2-3/4

25/32

PEML-10

2-1/2

5

30

2-7/16

3-1/4

1-1/16

PEML-12

3

5

34

3

3-7/8

1-1/16

PEML-14

3-1/2

5

39

3-1/2

4-3/8

1-1/16

PEML-16

4

2

56

4

5

1-1/16

10A–18

Poly PRECISION MOLDED INSULATING BUSHINGS

A rugged, high strength molded
bushing for general use on rigid
conduit connectors and similar
installations.
Listed by Underwriters Laboratories
Inc. for 105° C (221° F). Meets all
requirements of National Electrical
Code for insulating bushings.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

I.D.

PM-2

1/2

100

1

19/32

1-1/16

13/32

PM-3

3/4

100

1

25/32

1-5/16

13/32

PM-4

1

50

2

1

1-5/8

1/2

PM-5

1-1/4

25

3

1-5/16

2

1/2

PM-6

1-1/2

25

3

1-17/32

2-7/32

9/16
9/16

Nominal Dimensions (Inches)
O.D.
Height

PM-8

2

10

6

1-31/32

2-21/32

PM-10

2-1/2

5

11

2-5/16

3-5/16

5/8

PM-12

3

5

14

2-7/8

3-15/16

11/16

PM-14

3-1/2

5

22

3-5/16

4-7/16

11/16

PM-16

4

5

23

3-25/32

4-29/32

11/16

PM-20

5

2

40

4-13/16

6-3/16

31/32

PM-24

6

2

50

5-3/4

7-9/32

31/32

E25237
LISTED

310
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 311

Fittings and Accessories

FIXTURE HANGERS
SWIVEL SELF ALIGNING OUTLET BOX COVERS

Types SA-342 and SA-42
Adalet self-aligning covers provide flexible suspension
assuring plumb alignment of the lighting fixture regardless of
ceiling structure or angle. Fixtures hung from these aligner
covers can be hit or bumped without damage that would be
caused if rigidly mounted.

Catalog
Number

Unit
Carton
Qty.

Standard
Package

Approx
Wt.
Std. Pkg.

*SA-342

25

100

41

SA-42

25

100

50

10A–19

Made of stamped steel, these Aligner Covers are equipped
with ball joint allowing the fixture to swing through an angle
of 20° in any direction of the perpendicular. The SA-342 has
two sets of supporting screw hole centers for 3-1/4” and 4”
octagonal outlet boxes and covers are spotted for 2-3/4”
mounting centers. Type SA-42 has two sets of supporting
screw holes for 4” square outlet boxes and covers are
spotted for 3-1/2” and 2-3/4” centers for 4” and 3-1/2”
octagonal boxes.

Ball tapped for 1/2” stem.

SA-342

SA-42

*

UL Listed E88804
311

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 312

Sky-Tie™ — Bus-Drop Cable Clamps
Supports...
Cable up to 1-1/8" diameter. Uniform “lap” design of each
clamp-half results in support along the entire quarter bend.

Anchors...
Cable for 90° angle transitions using a simple, two-piece
construction of interchangeable clamp-halves.

Loops...
Excess cable for convenient handling and out-of-the-way
storage, via the Sky-Tie™ SHD Duplex Converter. The SHD
reduces the need to cut cable when machines are moved to
new locations. The SHD converter simply fits between the
two halves of the Sky-Tie™ SH cable clamps.

Perfect For:
• Machine Tools
• Portable Tools
• Air Lines
• Other heavy-cable support applications.

10A–20

Sky-Tie™ Springs
Heavy-duty Sky-Tie™ Springs insure tautness of the cable,
while absorbing vibrations and shocks. Each spring slips into
the Sky-Tie™ clamp at its outside bend (or, if using the SHD
Duplex, the converter’s outside bend), and ties back to a
structural member. Three spring models with maximum load
capacities of 60, 70 and 160 pounds.
Sky-Tie™ Springs
Catalog
Number

Max.
Spring
Load

Carton
Approx.
Qty.
Wt.

Std. Pkg.
Approx.
Qty.
Wt.

SHS-50

60 lbs.

10

2.2

50

11

SHS-75

70 lbs.

10

2.7

50

14

SHS-1125 160 lbs.

10

11

10

11

SH
SHD

SHS

Sky-Tie™ Two-In-One Cable Clamps
Catalog
Number

Cable OD
(Inches)

Typical Multi-Conductor
Cable Size

Carton
Approx.
Qty.
Wt.

Std. Pkg.
Approx.
Qty.
Wt.

SH-50

1/2 to 3/4

14/4 thru 8/4

10

3.5

50

SH-75

3/4 to 1-1/8

8/4 thru 3/4 or (1) 500 MCM

10

7

50

18.5
36

SH-1125

1-1/8 to 1-11/16

Special Applications

5

10

25

50

Lugs prevent nuts
from turning.
Keyhole slots permit assembly on cable
without removal of bolts or threading of
cable through fitting.

Sky-Tie™ “Duplex” Component
Catalog
Number

Cable OD
(Inches)

Typical Multi-Conductor
Cable Size

Carton
Approx.
Qty.
Wt.

Std. Pkg.
Approx.
Qty.
Wt.

SHD-50

1/2 to 3/4

14/4 thru 3/4

10

3.25

50

17.25

SHD-75

3/4 to 1-1/2

8/4 thru 3/4 or (1) 500 MCM

10

7

50

36

312
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 313

Cable Couplers
Portable Cable Systems Couplers/Plugs-Receptacles
Cable Couplers Identification & Application
Basic nomenclature identifies the metallic shell (Plug or Socket)
first, the type of contact (Male or Female) second. For
switchgear or other non-cable mounted units, the letter G suffix
designation is added. Example of the PLM Catalog number
system is as listed:

Other added options available for the coupler and catalog
number identification is listed.
Spare part requirements are minimized by widely
interchangeable components.
Suggested application of cable couplers is a plug on one end
of a cable and a socket on the other end. Common usage has
the socket being on the source end and the plug on the load
end.

PMG 415A

Plug, male contacts, switchgear mount, with ground check contact.

PML 415A

Plug, male contacts, line mount, with ground check contact.

SFL 415A

Socket, female contacts, line mount, with ground check contact.

SFG 415A

Socket, female contacts, switchgear mounted, with ground check contact.

PLM Cable Coupler Selection Guide
*
ADDED FEATURES

*

HOUSING

CONTACTS

MOUNTING
VOLTAGE CLASS
& END BELL SIZE

S Socket
F Female
G Gear Mount
Q Prefix PLM
P Plug
M Male
L Line Mount
Quick
Thread
style
EXAMPLE
double
Q P M L 415 A B
start Acme
thread
INTERLOCK COVER
QUIK THREAD
T Quick Turn
FOR PLUG
PLUG
Ramp Style
ONE GROUND
MALE CONTACTS
Blank
CHECK CONTACT
Standard
LINE MOUNT
DURA-TUBE INSULATOR
Thread

GROUND CHECK

Fiberglass Insulator
475 or 575
EPDM (Rubber) Insulator
415 or 515 Dura-Tube
366 Continuous Shield

A - One Contact Included
AA - Two Contacts
AAA - Three Contacts
AAAA - Four Contacts

B
BB
C
D
L
N

Interlock contacts in cover for plug
Interlock contacts in cover for socket
Kirklock sockets only
Pan skid mount
Insulation in plug cover
Non-interchangeable amperage or
voltage index
P Padlock provision socket
R Insulation in socket cover
TF Teflon Insulator
X Long end bell
Z Beryllium contacts

Applications

Features

Benefits

•
•
•
•
•
•
•
•

•
•
•
•
•
•

•
•
•
•
•
•

Extending Portable Cables
Mine Power Centers
Electric Shovels, Drills, Draglines
Tunneling Machines
Transformer Connections
Barge, Ship-Dock Applications
Turbine Generators
Motor Disconnect 600V-15kV to
500 Amp.

•
•
•
•

Corrosion-Resistant Aluminum
Electrically Tested Insulator
Silver-Plated Copper Contacts
Ground Check System
Portable Cable Connections
Switchgear or Equipment
Mounting
Standard Cover Included
FSD Terminations Included
Interlock Covers Available
Filling Compounds

Typical Surface Mine

Physical, Electrical Protection
Quick, Connect-Disconnect
Provides Proper Phase Alignment
Longer Coupler Life
Entirely Watertight
Easy Installation

11A–1

THREAD

Compliance
• Pennsylvania Bureau of Deep
Mine Safety

PORTABLE BREAKER SKID

1. Female sockets on source side of
substations, line, and portable skids.
2. Male plugs on load side of skids, loader and
stripper.
SUBSTATION

SUBSTATION

HIGH WALL

To Order, Provide:
1. Catalog numbers.
2. Voltage requirements.
3. Conductor sizes of phase, ground wires, and
ground check wire.
4. Overall cable diameter. Also on 366 series,
diameter over each phase conductor
insulation.

LOADER

STRIPPER

313
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 314

Portable High-Voltage Cable Couplers 415, 515
EPDM Insulators — Dura-Tube

SM

500 Amperes • 15,000 Volts Maximum

Features

Benefits

• Corrosion-resistant aluminum

• Superior electrical and physical protection

• Rigid, non-breakable EPDM insulators

• Fewer mating problems

• 500 Amp contacts

• Quicker installation

• Portable cable mounting

• Quick connect-disconnect

• Switchgear or equipment mounting

• Versatile application

• Standard cover, stress control kit, instructions included

Compound is not included and is not required up to 7,500 volts.
Above 7,500 Volts and when compound is required, use
COLDPOUR® Compound. Do not use asphalt compound with
EPDM style couplers. Compound mandatory for 15kv.

Electrical Characteristics

Maximum Voltage Phase-to-Ground
1 Minute Dry Withstand AC
6 Hour Dry Withstand DC
15 Minute Dry Withstand DC
Corona Extinction Level
Basic Impulse Level

No Compound

With Compound

5.5
35.0
25.0
65.0
7.5
75.0

8.7
45.0
35.0
75.0
11.0
95.0

KV
KV
KV
KV
KV
KV

rms
rms
rms
rms
rms
crest

KV
KV
KV
KV
KV
KV

rms
rms
rms
rms
rms
crest

All tests per IEEE Standard 48-1990

Catalog Number
Standard Threads

Catalog Number
Acme
Quik-Thread

Ship Wt.
(lbs.)

Description

QSFG 415A
QPMG 415A

Equipment-mounted couplers
Socket, Female Contacts
Plug, Male Contacts

34
34

SFL 415 A
PML 415 A

QSFL 415A
QPML 415A

Line-mounted couplers
1.50-3.50 O.D. Cables
Socket, Female Contacts
Plug, Male Contacts

51
51

SFL 515 A
PML 515 A

QSFL 515A
QPML 515A

3.50-4.50 O.D. Cables
Socket, Female Contacts
Plug, Male Contacts

53
53

SFG 415 A
PMG 415 A

SFL 415 A

11A–2

Options Available at Additional Cost
Catalog
Number
Suffix
–A
–AA
–B
–BB
–C
–E
–L
–N
–P
–R
–X
–Z
–TF

Additional Options
Ground check circuit contact (1) included
Two ground check circuit contacts
Cover interlock for plug
Cover interlock for socket
Kirk interlock (key type)–sockets only
Electrolytic copper contacts–female
Cover/insulator assembly for plug
Non-interchangeable amperage or voltage index
Padlock provision-socket
Cover/insulator assembly for socket
Extended end bell for larger cable sizes
Beryllium contacts–male
Teflon Insulator

Series 415 and 515 are recommended for all existing
installations where 375, 475, 575, 154 and 155 series
couplers have been used and will interface with these
couplers. The Q prefix 2 1/2 turn Quik-thread is suggested
for new applications or those customers presently using
Quik-thread applications. Quik-thread, Quick-turn and 8
pitch couplers will not interface.
Note: Male/Female insulator and contact assemblies are
interchangeable within coupler housings.
Specify PF or SM in catalog selection or consult
factory.
On initial orders, one coupling wrench and one
contact wrench will be required. See page 11A–9.
For aluminum conductors, consult factory.

314
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 315

Couplers Teflon Insulators
415TF/515TF Portable High-Voltage Cable Couplers
ADALET-PLM NOW OFFERS AN IMPROVED HIGH VOLTAGE
MINING COUPLER INSULATOR SYSTEM
Combining a non-tracking, easy-to-clean hydrophobic material with an internal o-ring seal between tubes.

500 AMPERES

15,000 VOLTS MAXIMUM

Features
•
•
•
•
•
•
•
•
•

Corrosion-Resistant Aluminum
Rigid, Non-Breakable TEFLON® Insulators
500 Amp Contacts
Portable Cable Mounting
Switchgear or Equipment Mounting
Standard Cover, Stress Control Kit, Instructions Included
Solid Polyester Fiberglass Flange
Teflon Tubes O-ring Sealed to Flange
Nylon Lock Nuts for Positive Seal

SFL 415ATF

Electrical Characteristics
Benefits
•
•
•
•
•

Superior Electrical and Physical Protection
Fewer Mating Problems
Quicker Installation
Quick Connect-Disconnect
Versatile Application

Maximum Voltage Phase-to-Ground
1 Minute Dry Withstand AC
6 Hour Dry Withstand AC
15 Minute Dry Withstand DC
Corona Extinction Level
Basic Impulse Level

No Compound
5.5 kV rms
35.0 kV rms
25.0 kV rms
65.0 kV aver
7.5 kV rms
75.0 kV crest

With Compound
8.7 kV rms
45.0 kV rms
35.0 kV rms
75.0 kV aver
11.0 kV rms
95.0 kV crest

All tests per IEEE Standard 48-1990

Compound is NOT included and is not required up to
7,500 Volts. ABOVE 7,500 Volts and when compound
is required, use COLDPOUR® Compound, Do NOT
use asphalt compound.

Options Available at Additional Cost
Catalog
Number
Suffix

NOTE: Male/Female insulator
and contact assemblies
are interchangeable
within coupler housings.
Specify PF or SM in
catalog selection or
consult factory. On initial
orders, one coupling
wrench and one contact
wrench will be required.
See page 11A–9. For
aluminum conductors,
consult factory.
Teflon® is a registered
trademark of E.I. DuPont
de Nemours and Company

-A
-AA
-B
-BB
-C
-E
-L
-N
-P
-R
-X
-Z

Additional Options
Ground Check Circuit Contact (1) Included
Two Ground Check Circuit Contacts
Cover Interlock for Plug
Cover Interlock for Socket
Kirk Interlock (Key Type)-Sockets Only
Electrolytic Copper Contacts-Female
Cover/Insulator Assembly for Plug
Non-Interchangeable Amperage or Voltage Index
Padlock Provision-Socket
Cover/Insulator Assembly for Socket
Extended End Bell for Larger Cable Sizes
Beryllium Contacts-Male

11A–3

Series 415 and 515 are recommended for all existing
installations where 375, 475, 575, 154, and 155
series couplers have been used and will interface
with these couplers. The Q prefix 2 1/2 turn QuikThread or threadless Quik-Turn is suggested for new
applications or those customers presently using such
couplers. Quik-Thread, Quik-Turn and 8 pitch couplers
will not interface.

Catalog Number and Description
Catalog No.
Stand. Threads

Catalog No.
Quik-Thread

Catalog No.
Quik-Turn

Description

Ship Wt.

SFG 415ATF

QSFG 415ATF

TSFG 415ATF

Socket, Female Contacts

34

PMG 415ATF

QPMG 415ATF

TPMG 415ATF

Plug, Male Contacts

34

EQUIPMENT-MOUNTED COUPLERS

LINE-MOUNTED COUPLERS
1.50-3.50 O.D. Cables
SFL 415ATF

QSFL 415ATF

TSFL 415ATF

Socket, Female Contacts

51

PML 415ATF

QPML 415ATF

TSFL 415ATF

Plug, Male Contacts
3.50-4.50 O.D. Cables

51

SFL 515ATF

QSFL 515ATF

TSFL 515ATF

Socket, Female Contacts

53

PML 515ATF

QPML 515ATF

TPML 515ATF

Plug, Male Contacts

53

315
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 316

Cable Couplers T415, T515
Quik-Turn
Application
• New installations where maximum convenience and
speed is required
• Existing installations where abusive conditions cause
thread damage

Features (Quik-Turn Couplers)
• 1/4 turn engagement for fast connection.
• Stainless steel pin and sleeve for corrosion resistance.
• Color coded orange for high visibility identification.

1

• Fully interchangeable with other threadless couplers using
EPDM insulators.

2

• Spare parts common to PLM 8 pitch and Quik-Thread
coupler designs.

3
4

Ratings

5

500 Amperes, 15,000 Volts Max.

6
7
8
9
10
11

Approvals

Features (Common to All PLM Couplers)

Pennsylvania Bureau of Deep Mines Safety – BOTE 1363-92

1 Heavy duty Ecoalube coated aluminum castings for high
strength and corrosion protection.
2 Completely metal enclosed insulators, O-ring sealed.

Catalog Number
Quik-Turn

Description

3 Rigid non-breakable DURATUBE EPDM insulator tubes
eliminate mating problems. Grey color provides easy
check of cleanliness.

Ship Wt. (lbs.)

11A–4

TSFG 415A
TPMG 415A

Equipment-mounted Couplers
Socket, Female Contacts
Plug, Male Contacts

TSFL 415A
TPML 415A

Line-mounted Couplers
1.50-3.50" O.D. Cables
Socket, Female Contacts
Plug, Male Contacts

TSFL 515A
TPML 515A

3.50-4.50" O.D. Cables
Socket, Female Contacts
Plug, Male Contacts

34
34

4 Close tolerance, silver plated contacts provide reliable
connections and assured conductivity.
5 Smooth profile end bell resists snags.
6 Solid one piece flame retardant flange with O-rings on
both sides insures against the entrance of moisture.

51
51

7 FSD stress relief pads provide fast, safe, dependable
cable terminations within coupler housing.
53
53

8 Easy access chamber for COLDPOUR® filling compound
when required.
9 Rugged cable entrance clamp and thick neoprene gasket
for excellent moisture seal at cable entrance.
10 Ground check circuit contact is included. Additional
contacts available.
11 Captive metal covers to keep insulators clean and dry
when disconnected.

Electrical Characteristics

Maximum Voltage Phase-to-Ground
1 Minute Dry Withstand AC
6 Hour Dry Withstand DC
15 Minute Dry Withstand DC
Corona Extinction Level
Basic Impulse Level

No Compound

With Compound

5.5
35.0
25.0
65.0
7.5
75.0

8.7
45.0
35.0
75.0
11.0
95.0

KV
KV
KV
KV
KV
KV

rms
rms
rms
rms
rms
crest

KV
KV
KV
KV
KV
KV

rms
rms
rms
rms
rms
crest

All tests per IEEE Standard 48-1990

316
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 317

Portable High-Voltage Cable Couplers 475, 575
Polyester Fiberglass Insulator 500 Amperes • 7,500 Volts Maximum
Electrical Characteristics*
This series is the same as the 415 and 515 series except the
insulator is polyester fiberglass rather than EPDM.
COLDPOUR® compound must be ordered as a separate item.

Maximum Voltage, Phase-to-Ground
15 Minute Dry Withstand D.C.
1 Minute Dry Withstand 60Hz
6 Hour Dry Withstand 60Hz
Corona Extinction Level

5.5
65.0
35.0
25.0
7.5

kV
kV
kV
kV
kV

rms
aver
rms
rms
rms

All tests per IEEE Standard 48-1962.
* Filled with compound

Catalog Number

Description

Ship Wt.
(lbs.)

SFG 375 A
PMG 375 A

Equipment-mounted couplers
Socket, Female Contacts
Plug, Male Contacts

32
32

SFL 475 A
PML 475 A

Line-mounted couplers
1.50-3.50 O.D. Cables
Socket, Female contacts
Plug, Male contacts

50
50

SFL 575 A
PML 575 A

3.50-4.50 O.D. Cables
Socket, Female contacts
Plug, Male contacts

52
52

SFL 475 A

Options Available at Additional Cost

–A
–AA
–B
–BB
–C
–E
–L
–N
–P
–R
–X
–Z

Additional Options
Ground check circuit contact (1) included
Two ground check circuit contacts
Cover interlock for plug
Cover interlock for socket
Kirk interlock (key type)–sockets only
Electrolytic copper contacts–female
Cover/insulator assembly for plug
Non-interchangeable amperage or voltage index
Padlock provision-socket
Cover/insulator assembly for socket
Extended end bell for larger cable sizes
Beryllium contacts–male

11A–5

Catalog
Number
Suffix

Data Required on Order
Note: Male/Female insulator and contact assemblies are
interchangeable within coupler housings.

• Sizes and number of ground checks
• Phase conductor size

Specify PF or SM in catalog selection or consult
factory.

• Catalog number
• Overall O.D. of cable

On initial orders, one coupling wrench and one contact
wrench will be required. See page 11A–9. For
aluminum conductors, consult factory.

• Sizes and number of ground wires
• Voltage class

317
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 318

Portable High-Voltage Cable Couplers 366
EPDM Insulators — Continu-Shield SM 200 Amperes • 6,600 Volts Maximum
Features

Benefits

• Corrosion-resistant aluminum

• No compound required

• Compact design

• Small size, lightweight

• Unbreakable molded EPDM insulators

• More economical

• Continuous shield design

• Better fault protection

• Airtight insulator connection

• Better electrical characteristics

• Double start Acme thread

Electrical Characteristics
Maximum Voltage, Phase-to-Ground
1 Minute Dry Withstand AC
6 Hour Dry Withstand AC
15 Minute Dry Withstand DC
Corona Extinction Level
Basic Impulse Level

3.8
35.0
25.0
65.0
7.5
75.0

kV
kV
kV
kV
kV
kV

rms
rms
rms
aver
rms
crest

All tests per IEEE Standard 48-1962

Catalog Number

Description

SFL 366A

Ship Wt.
(lbs.)

SFG 366 A
PMG 366 A

Equipment-mounted couplers
Socket, Female Contacts
Plug, Male Contacts

11
11

SFL 366 A
PML 366 A

Line-mounted couplers
Socket, Female contacts
Plug, Male contacts

17
17

11A–6

Options Available at Additional Cost
Catalog
Number
Suffix
–A
–AA
–BL
–BBR
–P
–C

Additional Options
Ground check circuit contact (1) included
Two ground check circuit contacts
Cover interlock for plug
Cover interlock for socket
Padlock provision-socket
Kirk interlock (keytype) sockets only

Data Required on Order
• Catalog number
• Sizes and number of ground wires

Note: On initial orders, one coupling wrench will be required.
See page 11A–9.

• O.D. over insulation of phase conductors
• Voltage class

Maximum diameter over phase insulation .840".

• Sizes and number of ground checks

Maximum conductor size 4/0 Awg.

• O.D. of cable over jacket

For use on copper cable only. For aluminum cables,
consult factory.

• Phase conductor size and type
• Class of stranding
• For unshielded cables, order kit #A1746

318
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 319

Other Portable Cable Products PCF, WACS
Cable Strain Relief PCF
Flange-mounted cable strain reliefs provide gasket-sealed, strain-relief entrance of portable cables into metal-clad
equipment. All hardware, fasteners and gaskets are included.

Type PCF and PCFL
Round Cables
Catalog
Number
PCF
PCF
PCF
PCF
PCF
PCF
PCF
PCF
PCF
PCF

Cable Range

175
200
225
250
275
300
325
350
375
400

1.50-1.75
1.75-2.00
2.00-2.25
2.25-2.50
2.50-2.75
2.75-3.00
3.00-3.25
3.25-3.50
3.50-3.75
3.75-4.00

9/16 DIA. 6 HOLES
EQUALLY SPACED

41/2 ID

6 1/8 BC

7 1/4 DIA.
MOUNTING DIMENSIONS

For Blind Tap mounting holes add suffix
“L”. On all orders Cable Diameter must
be specified.

Wire Armored Cable Support WACS
Type WACS Cable Supports are designed for use as supports for wire armored cable in borehole or vertical
wireways. In such applications, the cables are usually wire armored and supported at the top by the wire armor.
Single support systems are particularly useful for primary distribution in high-rise buildings where permissible. In
accessible locations the cable may be clamped to the side wall in addition to the top support. The supports should
be chosen first on the basis of weight to be supported and secondly, on diameter of cable. Fabricated from steel
plate and hot-dip galvanized.
Order by catalog number and include description and O.D. of cable.
C DIA

CONDUCTOR
EYEBOLT FOR
CONVENIENCE IN
PLACING CABLE

11A–7

INSULATION
LEAD SHEATH

JUTE

B DIA
MAX. DIA
OF CABLE

GALVANIZED STEEL WIRE APPLIED
25 TO 50 FEET APART WHEN CABLE
IS SUPPORTED ONLY AT THE TOP.

A DIA

Discount Schedule A
Dimensions (Inches)
Catalog
Number

Weight
Capacity (lbs.)

Max.
Cable O.D.

A

Three Plate Support
B
C

WACS238
WACS288
WACS338
WACS388
WACS330
WACS380
WACS420

7500
7500
7500
7500
10000
10000
10000

2.37
2.87
3.37
3.87
3.37
3.87
4.25

9.75
9.75
9.75
9.75
12.00
12.00
12.00

2.60
3.10
3.60
4.10
3.60
4.10
4.50

3.00
3.50
4.00
4.50
4.00
4.50
4.90

Ship Weight
(lbs.)
50
50
50
50
80
80
80

319
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 320

Other Portable Cable Products CP, PCK
COLDPOUR® Compound* CP
Compound filling can prevent condensation and provide added protection in wet locations. Asphaltic
compounds cannot be used with EPDM insulations. For those customers who may wish to use compound,
ADALET offers a COLDPOUR® compound which does not require heating for installation or removal.
Suitable for all couplers. No shrinkage or waste. Approximately 2-hour gel time.
Catalog
Number

Shipping
Weight (lbs.)

Description

CP-40

1 5/8 gal. 2-part mix for one LINE mount or two
GEAR mount couplers, Series 415 or 475 coupler.

13

CP-50

1 7/8 gal. 2-part mix for one LINE mount, Series
515 or 575 coupler

14

CP-55

2 1/4-gal. 2-part mix for one Suffix-X LINE mount
coupler with extended end bell.

24

*Shelf life, 6 mos. Should be installed at normal room temperature.

Coupler Contact Insulation Cleaning Kit
Dirt contamination can cause electrical failures. The mating contact insulators can be efficiently cleaned
with the PCK100 Cleaning Kit.
Kit consists of 16-oz. aerosol can of non-flammable electrical parts cleaner, bristle brush, two white wiping
cloths and polyethylene glove. Ozone-safe spray can contains no fluorocarbons.

Catalog
Number
PCK-100

Description
Cleaning Kit

Shipping
Weight (lbs.)
1 1/2

11A–8
Replacement Coupler Insulators
Insulator kits to replace polyester fiberglass and cone seal style insulators
Complete package includes rigid, unbreakable insulator tubes with flame-retardant flange and all necessary
conductor and insulation shield terminating material except contacts. May be used with existing PLM
Couplers. Add COLDPOUR® for 15kV applications.

Catalog
Number
K
K
K
K

415
415
415
415

F
M
FG
MG

Shipping
Weight (lbs.)

Description
For
For
For
For

female line plugs or sockets
male line plugs or sockets
female gear-mount plugs or sockets
male gear-mount plugs or sockets

10
10
8
8

320
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 321

Other Portable Cable Products Type QT
Conversion Kits QT
Any cable coupler line mount or gear mount may be
converted to Acme double start Quik-Thread style or
Quik-Turn style. These style couplers will not mate with
standard 8 pitch thread couplers; therefore, it is necessary
to change the socket body, lock ring, and covers. Select
the correct conversion plug or socket kit from the table
below. Kits include only the thread parts which must be
changed, plus new screws and gaskets.
Quik-Thread coupler rings are color-coded green to
provide positive identification. Quick-Turn coupler rings are
color-coded orange. Conversion kits should be applied to
all couplers on any single cable system.

Acme Thread Parts Furnished

QKS-8

Description

QKP-8
TKP-8

Plug cover and lock ring

Replacement for plug-style couplers. Includes plain cover (without
drilling for pilot or ground contacts).

QKP-M/F-8
TKP-M/F-8

Plug cover (drilled for pilot and ground
contacts) and lock ring

Replacement for plug-style couplers. Includes cover drilled for ground
and pilot contacts (male or female). Customer to use existing contacts.

QKP-M/F-15
TKP-M/F-15

Plug cover (drilled for pilot and ground contacts
and for cover insulator assembly) and lock ring

Replacement for plug-style couplers. Includes cover drilled for ground
and pilot contacts (male or female) and for cover insulator assembly.
Customer to use existing contacts and cover insulator assembly.

QKS-8
TKS-8

Socket cover and socket body

Replacement for socket-style couplers. Includes plain cover (without
drilling for pilot or ground contacts).

QKS-M/F-8
TKS-M/F-8

Socket cover ring and socket body

Replacement for socket-style couplers. Includes cover ring to be used
with existing cover. Customer to use existing contacts.

QKS-M/F-15
TKS-M/F-15

Socket cover ring and socket body

Replacement for socket-style couplers. Includes cover ring to be used
with existing cover and cover insulator assembly. Customer to use
existing contacts.

11A–9

Catalog
Number

QKP-8

Coupler Wrenches
Catalog
Number

Shipping
Weight (lbs.)

Description

WR

Contact wrench for 415, 515, 475, 575 series

1

C-1008

Coupling wrench (Aluminum) for 415, 515,
475, 575 series

1

C-1008-S

Coupling wrench (Steel) for 415, 515, 475,
575 series

3

C-1678-S

Coupling wrench (Steel) for 366 series

3

CONTACT WRENCH
COUPLING WRENCH

321
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 322

Other Portable Cable Products Skids

Adalet Cable Couplers — Surface Mining Application
Because of operational convenience, economics, and added safety, many surface mining operations use Adalet
Couplers in conjunction with handling trailing cables. Adalet Couplers are designed so that the first circuit to open
and the last to close is the ground check, so that the circuit breakers cannot be operated until the ground and phase
contacts are connected. Furthermore all live parts are enclosed in the housing. Thus couplers provide a compact,
safe, watertight, and dust-tight connection.
For rugged surface conditions, Adalet has designed features and products to utilize couplers and provide rapid, safe
means for handling trailing cables.
For high inrush currents associated with surface mining equipment, Adalet provides high conductivity split copper,
silver plated, male contacts with pressure maintaining elastomeric inserts. Female contacts are silver plated high
conductivity copper.

QPMG415A

CABLE

CABLE
SKID

SUBSTATION

STRIPPER
QSFL415A

QPMG ON SUBSTATION, SKIDS, STRIPPER.
QSFL (LESS FEET) ON BOTH CABLE ENDS.

11A–10

Type Q – Quik-Thread

Type EP-1 Coupler Skid

Coupling rings with double start Acme thread permits
couplers to be connected or disconnected in only 2 1/2
turns. Special hardened and permanently lubricated
threads are recessed from the end of the coupler to
prevent damage and eliminate clogging and seizing.
Adalet Quik-Thread Style Couplers are color coded
green to provide positive identification.

For moving cables and support of cable couplers.
Couplers are mounted on a turntable positioned on skid.
A steel cable support in the center of the sled supports
cable loops which are fed off the back of the skid as the
equipment moves forward. Ten inch high posts on each
back corner of skid provide a tie point for pulling loops
when picking up cables, and prevent the cables from
sliding under the skid.

Type JB-1 Coupler Box
Compact, rugged steel plate box protects couplers from
rock fall and offers double environmental protection for
electrical connection. Fast connect-disconnect even in
the most adverse conditions. The coupler is positioned
on mounting pins, inside the skid house. For removal,
simply raise cover and lift out coupler and cable.
Mounted on skids, the skid house is equipped with tow
hooks providing rapid means of moving skid, coupler &
cable.

Type JB Skids
For cable handling ease and for two to three feeder
junction boxes. Normally wired with 1, 2, or 3 sockets
for outgoing power and one plug incoming. May be
utilized as illustrated above.

Type HB Sleds
Same as above, mounted on high runners for clearing
rubble.

322
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 323

Other Portable Cable Products Skids
Lowboy Skids 2-way, 3-way or 4-way
Factory-wired for 15 kV–500 ampere service
includes ground and ground check wiring.
Lowboy skids are used for two-way, threeway or four-way connections of portable
cables. Boxes are wired internally and
compound-filled. Prices do not include
couplers – order separately.

Catalog
Number
LB-2
LB-3
LB-4

Application
2-way
3-way
4-way

Hi-Boy Sleds 2-way, 3-way or 4-way
Factory-wired for 15 kV–500 ampere service
includes ground and ground check wiring. Hiboy sleds offer tubular runners suitable for
clearing rubble or keeping couplers out of
mud, water or snow. Boxes are wired
internally and compound-filled. Prices do not
include couplers – order separately.

Catalog
Number
HB-2
HB-3
HB-4

Application
2-way
3-way
4-way

JB-1 Coupler Box
•

3/16”

steel plate fabrication

• Compact design
• Skid-mounted
• Cable entry seal and support
• Painted safety yellow
• Hinged cover with provision for
padlock

Benefits
• Maximum physical protection of
coupler
• Protects coupler from
environment
• Simplifies cable movement
• Labor and material cost savings
when compared with highvoltage connection boxes

11A–11

Features

24"
24"
72"

EP-1 Coupler Skid
Features
•

1/2”

steel plate construction

• Compact design
• Turntable coupler mount
• Steel cable support
• Protects cable from sharp bends

Benefits
• Rugged design prevents couplers
from snagging when moving
equipment in rough terrain
• Simplifies the movement of
trailing cables
16"

• Reduced cable handling
downtime
• Offers superior electrical features
of using cable couplers

24"
72"

323
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 324

Systems

Voltage Selection
In many mining systems the
original and replacement costs
of cable can become a major
item of expense. From an
economic standpoint, the
distribution voltage should be
as high as possible. At 7500
volts, the cost of cables is
approximately half of the cost
of cables required to handle the
same load at 2300 or 4160
volts with very little extra cost
on the other electrical
equipment. 13.2kV equipment
is considerably more expensive
than 7500 volt equipment, but
in boreholes, or where long
cable runs are necessary in
open pit mines, the use of
15kV cables and couplers can
be advantageous.
TYPICAL SYSTEM FOR A-C POWER IN DEEP MINING

11A–12

Ground Check and Key Interlock Methods
With a total of four pilot wire contacts available, the Adalet Coupler is adaptable
to any presently used ground check system. In addition to the electrical
interlock (ground check system), mechanical key type locks may be used to
insure no voltage disconnection of couplers.

Coupler Covers
SCHEMATIC OF TYPICAL
GROUND CHECK SYSTEM

STANDARD

WITH PILOT
AND GROUND
CONTACTS

WITH INSULATOR,
PILOT AND GROUND
CONTACTS

The Adalet Coupler is furnished with the Standard Cover. This prevents moisture
and contamination from coming in contact with the coupler insulator and
contacts.
When it is desired to have the Cover equipped with a Pilot contact and a
Ground contact, add the suffix letter “B” to the catalog number for Plug style
coupler and letter “BB” for Socket style coupler. With these contacts installed
it is then possible to check the integrity of the Ground Check circuit.
The covers are available with an insulator, pilot contact, and ground contact. It
is then possible to energize the cable without the coupler being connected to
another coupler. Add the suffix letters “BL” to the catalog number for Plug
style coupler and letters “BBR” for Socket style coupler.

324
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 325

Couplers
PLM: The Leading Coupler in the Mining Industry
A History

Use

PLM products began in 1951 as a supplier of cable
accessories for high voltage cables. Although Cable
Couplers had been used in the mining industry, it was not
until 1957 when requirements began to develop for voltages
higher than 5kV and Amperages greater than 200 Ampere
that the first 7.5kV 500 AMP Coupler was developed by
PLM Products.
Published test values backed by a high voltage laboratory
and continuous innovations have kept PLM Products, now
known as Adalet, as a world leader of cable couplers.

Couplers have been utilized in underground, strip, and pit
operations on every continent in the world, and for coal and
hard rock mining operations of every type. Adalet Cable
Couplers provide safe, convenient means for connecting
portable cable rated up to 15,000 volt and up to 500
Amperes, copper or aluminum conductor to mining
equipment, electric shovels, draglines, loaders, barges,
tunneling machines, portable substations, portable junction
boxes, or for joining lengths of high voltage cables.
Housings are of rugged, corrosion resistant cast aluminum
providing high strength with light weight. Thorough
gasketing makes the coupler entirely watertight. Tight fitting
covers for plug and socket, protect contacts and insulators
from moisture when disconnected.

Design
From the beginning, PLM designed Couplers to standards
subsequently incorporated into mine safety codes in the
United States. All PLM Couplers are completely metal
enclosed with the outer shell grounded to the ground wires
in the cable. Couplers are designed so that the first contact
to make and last to break is the ground contact. With
ground check circuits the Coupler ground check circuit is the
last to make and first to break. The ground contact is also
grounded to the housing assuring the operator that the
Coupler is grounded.

Positive thread engagement of the metal housing prevents
accidental disconnecting and insures proper opening and
closing sequence. For further safeguard, optional electrical
and mechanical (key type) systems are available.

Other Couplers Available Upon Request
Note:

Male/Female assemblies are
interchangeable within housings. Specify
PF or SM or consult factory.

11A–13

All additional options are available for the
above coupler.

325
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A 12/9/01 11:24 AM Page 326

Couplers Dimensional Data

11A–14
326
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 327

Indoor Termination Kits 5 - 35 kV
For Use on Solid Dielectric Cable
Each indoor kit includes material to make three single- or one three-conductor termination. Kit includes three FSD
pads, high voltage tape, abrasive cloth and instructions.

Catalog No.

Cable Range

FSD
FSD35
FSDS35*

#8–600MCM
#1–1000MCM
#1–1000MCM

Voltage Application
5kV(100%)–25kV(100%)
25kV(133%)–35kV(100%)
25kV(133%)–35kV(100%)

* Silicone overwrap for contaminated areas – indoor only.

APPLICATION OF COVER TAPE

INSTALLATION OF SINGLE WRAP
STRESS CONTROL PAD

Outdoor Termination Kits 5 kV - 25 kV
For Use on Solid Dielectric Cable

Catalog No.
FSDS1
FSDS2

Cable Range
#8–600MCM
#8–600MCM

11A–15

Each outdoor kit includes material to make three single- or one
three-conductor termination. Kit includes three FSD pads, high
voltage tape, abrasive cloth, silicone tape, PVC all-weather tape
and instructions.

Voltage Application
5kV(100%)–15kV(100%)
15kV(133%)–25kV(100%)

Grounding Kits & Pads

Catalog No.
FSDP3
FSDP35
FSD35*

Cable Range
3 Extra Pads
3 Extra Pads
3 Extra Pads

Voltage Application
5kV(100%)–25kV(100%)
25kV(133%)–35kV(100%)
25kV(133%)–35kV(100%)

327
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 328

PowerSpec™
Type PS Description
Use where jacketed metal clad (MC) cable is installed in a
non-hazardous or Division 2 area when sealing is not
required. The connector is hexagonally designed for easy
wrenching with a minimal overall length. The connector is
UL listed according to UL 514B and does not require any
disassembly to install.

Features
Fast, simple installation
360° grounding system
provides superior conductivity
Durable seal prohibits cable
twisting or pull-out

Applications
For terminating TECK and jacketed Metal Clad cable. For
vertical or horizontal runs.

Watertight (UL-50 listed as a
Type 4 cable fitting)
Compact design
Lightweight and corrosion
resistant

Certifications

Material/Finish

Applicable Standard
Meets UL standard for raintight armored cable fitting.

Body, Nut: Copper-Free Aluminum
Flange Gasket, Grommet:
Neoprene

PowerSpecX (Class I, Div. 1 and 2, Haz.
Locations)

Armor Stop: Phenolic

Type PSX Description
Use where jacketed MC cable is installed in a Class I,
Division 1 area or a Class I, Division 2 area when sealing is
required, i.e. enclosures containing arcing or sparking
devices. The connector is hexagonally designed for easy
wrenching with a minimal overall length. An epoxy type
sealing compound is used and the connector is UL listed
according to UL 2225.

Spring: Phosphur Bronze

Standard Sizes
Applications
Terminates and seals jacketed continuous corrugated MC
cable in Class I, Div. 1 and 2 and TECK and jacketed
interlocked MC cable in Class I, Div. 2 locations. For vertical
or horizontal runs. Provides seal for cable core where armor
is removed and between the jacket and armor.

.55” - 2.18”

11A–16
PowerSpec for ordinary
locations, PowerSpecX
for hazardous locations there’s one suited for
your application

Certifications

power plants

Class I, Groups A, B, C, D

paper mills

Class II, Groups E, F, G

oil refineries

Applicable Standard
Meets NEC Sec. 501-5(e) requirements for sealing of MC
cable in Class I, Div. 1, and 2 hazardous locations. Also
meets UL standards for rain tight fitting in hazardous
locations.

offshore drilling platforms
waste treatment facilities
chemical plants

328
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/11/01 6:13 PM Page 329

Catalog
Number

Diameter
Over Jacket

Diameter
Over Armor

Maximum
Cable Core
Diameter

Conduit
Size

Fitting
O.D.

Length
Overall

Ship
Weight
(lbs.)

min.

max.

min.

max.

PS-065-05

0.55”

0.65”

0.45”

0.56”

0.56”

1/2”

1 5/8”

2 1/6”

1/4

PS-075-05

0.65”

0.75”

0.55”

0.66”

0.56”

1/2”

1 5/8”

2 1/6”

1/4

PS-085-05

0.75”

0.85”

0.65”

0.76”

0.56”

1/2”

1 5/8”

2 1/6”

1/4

PS-100-07

0.85”

1.00”

0.72”

0.90”

0.82”

3/4”

2”

2 3/16”

1/3

PS-115-07

1.00”

1.15”

0.87”

1.05”

0.82”

3/4”

2”

2 3/16”

1/3

PS-125-10

1.13”

1.25”

1.00”

1.15”

1.00”

1”

2 3/16”

2 7/16”

1/2

PS-138-10

1.25”

1.38”

1.12”

1.28”

1.00”

1”

2 3/16”

2 7/16”

1/2

PS-150-12

1.33”

1.50”

1.23”

1.40”

1.33”

1 1/4”

2 7/8”

2 7/8”

2/3

PS-168-12

1.50”

1.68”

1.40”

1.58”

1.33”

1 1/4”

2 7/8”

2 7/8”

2/3

PS-183-15

1.68”

1.83”

1.58”

1.73”

1.61”

1 1/2”

3 1/4”

3 5/8”

1

PS-200-15

1.83”

2.00”

1.73”

1.90”

1.61”

1 1/2”

3 1/4”

3 5/8”

1

PS-218-15

2.00”

2.18”

1.90”

2.08”

1.61”

1 1/2”

3 1/4”

3 5/8”

1

Maximum
Cable Core
Diameter

Conduit
Size

Fitting
O.D.

Length
Overall

Ship
Weight
(lbs.)

Catalog
Number

Diameter
Over Jacket

Diameter
Over Armor

min.

max.

min.

max.

PSX-065-05

0.55”

0.65”

0.45”

0.56”

0.56”

1/2”

1 5/8”

2 3/4”

5/8

PSX-075-05

0.65”

0.75”

0.55”

0.66”

0.56”

1/2”

1 5/8”

2 3/4”

5/8

PSX-085-05

0.75”

0.85”

0.65”

0.76”

0.56”

1/2”

1 5/8”

2 3/4”

5/8

PSX-100-07

0.85”

1.00”

0.72”

0.90”

0.82”

3/4”

2”

3 1/8”

7/8

PSX-115-07

1.00”

1.15”

0.87”

1.05”

0.82”

3/4”

2”

3 1/8”

7/8

PSX-125-10

1.13”

1.25”

1.00”

1.15”

1.00”

1”

2 3/16”

3 1/2”

1

PSX-138-10

1.25”

1.38”

1.12”

1.28”

1.00”

1”

2 3/16”

3 1/2”

1

PSX-150-12

1.33”

1.50”

1.23”

1.40”

1.33”

1 1/4”

2 7/8”

4 1/8”

1 1/4

PSX-168-12

1.50”

1.68”

1.40”

1.58”

1.33”

1 1/4”

2 7/8”

4 1/8”

1 1/4

PSX-183-15

1.68”

1.83”

1.58”

1.73”

1.61”

1 1/2”

3 1/4”

4 11/16”

1 3/4

PSX-200-15

1.83”

2.00”

1.73”

1.90”

1.61”

1 1/2”

3 1/4”

4 11/16”

1 3/4

PSX-218-15

2.00”

2.18”

1.90”

2.08”

1.61”

1 1/2”

3 1/4”

4 11/16”

1 3/4

11A–17

PowerSpec™

To Order: Select fitting based on diameter over jacket and armor by using the table above. For locknut and bushing, add suffix LB.

329
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 330

Fittings for Metal Clad Cables Jacket over Armor
Features/Benefits:
• Slip - on design with no disassembly for easy installation
• Neoprene bushing for raintight seal
• Locknuts, bushings and flange gasket included – no additional materials to purchase
• Flange gasket prevents moisture penetration through threads
• Made from copper-free aluminum alloy for corrosion resistance
• Fits broad range – .351-4.62 cable O.D.

C

Application:
• For terminating metal clad cable
D

Certification:

A

B

Class II
To Order:
Determine satisfactory fit by checking cable dimensions A and B.
If cable dimensions do not fall within acceptable range, consult factory.

E

Dimensions (Inches)

11A–18

A

B

C

D

E

Catalog
Number

Dia. Over Jacket
Min.
Max.

Max. Cable
Core Dia.

Conduit
Size

Fitting
O.D.

Length
Overall

JAG
JAG
JAG
JAG
JAG
JAG

45-05
55-05
65-05
75-05
85-05
95-05

.35
.45
.55
.65
.75
.85

.45
.55
.65
.75
.85
.95

.61
.61
.61
.61
.61
.61

1

JAG
JAG
JAG
JAG

99-07
107-07
113-07
121-07

.85
.92
.98
1.07

.99
1.07
1.13
1.21

.81
.81
.81
.81

3

JAG 112-10
JAG 125-10
JAG 138-10

1.00
1.12
1.22

1.12
1.25
1.38

JAG
JAG
JAG
JAG

138-12
156-12
174-12
188-12

1.28
1.38
1.56
1.74

JAG
JAG
JAG
JAG

174-15
188-15
200-15
218-15

JAG
JAG
JAG
JAG

/2
/2
1
/2
1
/2
1
/2
1
/2

1
1
1
1
1
1

/4
/4
3
/4
3
/4

1.00
1.00
1.00

1
1
1

1.38
1.56
1.74
1.88

1.25
1.25
1.25
1.25

1
1
1
1

1

1.60
1.74
1.88
2.00

1.74
1.88
2.00
2.18

1.63
1.63
1.63
1.63

1
1
1
1

1

219-20
236-20
247-20
261-20

2.05
2.19
2.35
2.47

2.19
2.36
2.47
2.61

2.09
2.09
2.09
2.09

2
2
2
2

JAG 263-25
JAG 280-25
JAG 296-25

2.46
2.62
2.80

2.63
2.80
2.96

2.49
2.49
2.49

JAG
JAG
JAG
JAG
JAG

297-30
311-30
327-30
343-30
359-30

2.80
2.95
3.10
3.26
3.42

2.97
3.11
3.27
3.43
3.59

JAG 375-35
JAG 392-35
JAG 412-35

3.52
3.75
3.90

JAG
JAG
JAG
JAG

4.05
4.20
4.34
4.43

423-40
437-40
451-40
462-40

2
2
2
2
2
2

1

/4
/4
1
/4
1
/4
1
/4
1
/4

1

1

1

2
2
2
2

2
2
2
2

5

/8
/4
1
/4
1
/4

1

1

1

2 3/8
2 3/8
2 3/8

3 1/16
3 1/16
3 1/16

1

/4
/4
1
/4
1
/4

2
2
2
2

7

/8
/8
7
/8
7
/8

3
3
3
3

3

/8
/8
3
/8
3
/8

2

3

2

/2
/2
1
/2
1
/2

3
3
3
3

1

/4
/4
1
/4
1
/4

4
4
4
4

1

/16
/16
1
/16
1
/16

1
1
1
1

4
4
4
4

4
4
4
4

5

/16
/16
5
/16
5
/16

1
1
1
1

2 1/2
2 1/2
2 1/2

4 23/32
4 23/32
4 23/32

5 7/16
5 7/16
5 7/16

2 1/2
2 1/2
2 1/2

3.11
3.11
3.11
3.11
3.11

3
3
3
3
3

5
5
5
5
5

5
5
5
5
5

3
3
3
3
3

3.75
3.92
4.12

3.61
3.61
3.61

3 1/2
3 1/2
3 1/2

5 11/16
5 11/16
5 11/16

5 13/16
5 13/16
5 13/16

3 1/4
3 1/4
3 1/4

4.23
4.37
4.51
4.62

4.11
4.11
4.11
4.11

4
4
4
4

6
6
6
6

5
5
5
5

3
3
3
3

1

3

1

1

/8
/8
5
/8
5
/8
5
/8
5
/8

Ship Wt.
(Lbs.)

5
5

7

1

/32
3
/32
3
/32
3
/32
3
/32
3

/32
/32
3
/32
3
/32
3
3

1

5

/4
3
/4
3
/4
3
/4
3
/4
3

/16
/16
13
/16
13
/16
13
13

/4
/4
1
/4
1
/4
1
/4
1
/4
/3
/3
1
/3
1
/3
/2
/2
1
/2
1

/3
/3
2
/3
2
/3

GLAND NUT

PRESSURE RING

/2
/2
1
/2
1
/2
1
1

NEOPRENE BUSHING

GROUNDING SLEEVE

ARMOR STOP

/2
/2
1
/2
1
/2
1
1

JAG BODY
GROUND SCREW
FLANGE GASKET
LOCKNUT
INSULATING BUSHING

330
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 331

Fittings for Metal Clad Cables Unjacketed Armor Dry Location
Features/Benefits:
• Wide armor range – sizes on .200 intervals
• Raised boss in strap offers excellent pullout protection
• Copper-free aluminum for corrosion resistance and
suitability with aluminum or galvanized steel armor

Certifications:
Note:
For use with Cable O.D. over armor
To Order:
Select fitting based on diameter over armor

Application:
For terminating metal clad cable with unjacketed armor in
dry locations

Dimensions (Inches)
For Use With
Cable O.D. Over Armor
Min.
Max.

A

B

C
Conduit
Size

D

G

H-J
Ship Wt.
(Lbs.)

AC6

.45

.64

.65

.40

3

/4

1 3/8

7

/8

1 3/8

1

AC8

.65

.84

.85

.60

1

1 13/16

1 1/8

1 11/16

1

AC10
AC12

.85
1.05

1.04
1.24

1.05
1.25

.80
1.00

1 /4
1 1/4

1 /8
2

1 /8
1 1/4

2
2

1

AC14

1.25

1.44

1.45

1.20

1 1/2

2 1/16

1 5/16

2 5/16

3

AC16
AC18

1.45
1.65

1.64
1.84

1.65
1.85

1.40
1.60

2
2

2 /8
2 3/8

1 /2
1 1/2

2 /8
2 5/8

1 1/2
1 1/2

AC20
AC22

1.85
2.05

2.04
2.24

2.05
2.25

1.80
2.00

2 1/2
2 1/2

2 5/8
2 5/8

1 5/8
1 5/8

3 1/4
3 1/4

1 3/4
1 3/4

AC24
AC26
AC28

2.25
2.45
2.65

2.44
2.64
2.84

2.45
2.65
2.85

2.20
2.40
2.60

3
3
3

2 3/4
2 3/4
2 3/4

1 3/4
1 3/4
1 3/4

3 3/4
3 3/4
3 7/8

2
2
2

AC30
AC32
AC34

2.85
3.05
3.25

3.04
3.24
3.44

3.05
3.25
3.45

2.80
3.00
3.20

3 1/2
3 1/2
3 1/2

3 1/8
3 1/8
3 1/8

2
2
2

4 7/16
4 3/8
4 9/16

2 3/4
2 3/4
2 3/4

AC36

3.45

3.64

3.65

3.40

4

3 1/8

1 15/16

5 1/8

3

AC38

3.65

3.84

3.85

3.60

5

3 1/4

2 1/16

6

4

AC40*

3.85

4.04

4.05

3.80

5

3 /16

2 /8

6

4 1/2

AC42*

4.05

4.24

4.25

4.00

5

3 1/4

2 1/4

6 1/8

4 1/2

AC44*

4.25

4.44

4.45

4.20

5

3 /4

2 /4

6 /8

4 1/2

AC46*

4.45

4.64

4.65

4.40

5

3 1/4

2 1/4

6 1/8

4 1/2

AC48*

4.65

4.84

4.85

4.60

5

3 /4

2 /4

6 /8

4 1/2

1

7

1

3

1

5

1

1

1

/2
/2

1

1

/2

1

5

1

/2

1

/4

11A–19

Catalog
Number

*CSA only

LOCKNUT

STRUCTURE

C = THREAD
INSULATING
BUSHING

GLAND
ARMOR STRAP

J

B

A

H
G
D

331
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 332

Fittings for Metal Clad Cables Jacket under Armor
Features/Benefits:
• Clamping action ensures a positive mechanical and
ground connection without damage to cable construction
• Fits broad armor range – sizes on .200” intervals
• Raised boss in strap offers excellent pull out protection
• Copper-free aluminum alloy for corrosion resistance and
suitability with aluminum or galvanized steel armor
• Gland provides watertight cable seal in all positions

Certification:

Note:
For use with cable O.D. over armor
To Order:
Select fitting based on diameter over bare armor

Application:
For terminating metal clad cable with jacket under armor

Dimensions (Inches)
A

B

C
Conduit
Size

D

G

H-J

11A–20

Catalog
Number

Dia Over Armor
Min.
Max.

Ship Wt.
(Lbs.)

ACS6
ACS8

.45
.65

.64
.84

.65
.85

.50
.70

3
/4
1

2 1/2
3

7
/8
1 1/8

1 1/2
2

1
1

ACS10
ACS12
ACS14

.85
1.05
1.25

1.04
1.24
1.44

1.05
1.25
1.45

1.10
1.10
1.35

1 1/4
1 1/4
1 1/2

3 1/16
3 5/16
3 3/8

1 1/8
1 1/4
1 5/16

2 1/4
2 1/4
2 3/8

1 1/2
1 1/2
1 1/2

ACS16
ACS18

1.45
1.65

1.64
1.84

1.65
1.85

1.70
1.70

2
2

3 3/4
3 3/4

1 1/2
1 1/2

3 1/16
3 1/16

1 3/4
1 3/4

ACS20
ACS22

1.85
2.05

2.04
2.24

2.05
2.25

2.12
2.12

2 1/2
2 1/2

4 3/8
4 3/8

1 5/8
1 5/8

3 1/2
3 1/2

2 1/2
2 1/2

ACS24
ACS26
ACS28

2.25
2.45
2.65

2.44
2.64
2.84

2.45
2.65
2.85

2.75
2.75
2.75

3
3
3

4 1/2
4 1/2
4 1/2

1 3/4
1 3/4
1 3/4

4 3/16
4 3/16
4 3/16

3
3
3

ACS30
ACS32
ACS34

2.85
3.05
3.25

3.04
3.24
3.44

3.05
3.25
3.45

3.30
3.30
3.30

3 1/2
3 1/2
3 1/2

4 7/8
4 7/8
4 7/8

2
2
2

4 11/16
4 11/16
4 11/16

4
4
4

ACS36

3.45

3.64

3.65

3.50

4

5 1/8

1 15/16

5 1/4

5

ACS38
ACS40
ACS42
ACS44
ACS46
ACS48

3.65
3.85
4.05
4.25
4.45
4.65

3.84
4.04
4.24
4.44
4.64
4.84

3.85
4.05
4.25
4.45
4.65
4.85

3.85
3.85
4.44
4.44
4.44
4.44

5
5
5
5
5
5

5
5
5
5
5
5

2
2
2
2
2
2

6
6
6
6
6
6

6
6
6
6
6
6

/2
/8
3
/8
3
/8
3
/8
3
/8
1
3

/16
/8
1
/4
1
/4
1
/4
1
/4
1
1

/16
/16
9
/16
9
/16
9
/16
9
/16
9
9

GASKET
BASE
GLAND

A

H

PRESSURE RING

1

STRUCTURE
LOCKNUT
C = CONDUIT SIZE
INSULATING BUSHING

ARMOR STRAP

J

/2
/2
1
/2
1
/2
1
/2
1
/2
1

B

G
D
GASKET

332
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 333

Cord Grip Fittings (Straight Body)
Note:
Consult factory for alternate materials (i.e., stainless
steel)

Features/Benefits:
• Aluminum body and nut for exceptional
corrosion resistance
• Tapered rubber bushing (grommet) provides
raintight, dust-tight seal and provides resistance
to cutting oils, age hardening, compression set
and normal temperature extremes
• Anti-friction washer is supplied between the nut
and bushing for ease in compression
• Machine cut threads prevent cross threading,
ensure smooth compression and watertight
make-up in conduit hubs
• Mesh option available in most sizes for
additional support
Applications:
For terminating cable in conduit hubs or knock-outs and
for providing relief from strain on cable
Certifications:

CGP (Straight Body)

Cable
Range
(Inches)

Catalog Number
Cord Grip
Only

/2
/2
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2

.125-.188
.188-.250
.250-.312
.312-.375
.375-.438
.438-.500
.500-.562
.562-.625

CGP
CGP
CGP
CGP
CGP
CGP
CGP
CGP

2188*
2250
2312
2375
2438
2500
2562
2625

/4
/4
3
/4
3
/4
3
/4

.438-.562
.500-.625
.562-.688
.625-.750
.688-.812

CGP
CGP
CGP
CGP
CGP

3562
3625
3688
3725
3812

1
1

3
3

1
1
1
1
1
1
1

.438-.562
.500-.625
.562-.688
.625-.750
.688-.812
.750-.875
.812-.938

CGP
CGP
CGP
CGP
CGP
CGP
CGP

4562
4625
4688
4750
4812
4875
4938

Catalog Number
Cord Grip
with Mesh

Conduit
Size
(Inches)

–
CGP
CGP
CGP
CGP
CGP
CGP
CGP

2250-M
2312-M
2375-M
2438-M
2500-M
2562-M
2625-M

CGP
CGP
CGP
CGP

3562-M
3625-M
3688-M
3725-M

–
CGP
CGP
CGP
CGP
CGP
CGP
CGP

4562-M
4625-M
4688-M
4750-M
4812-M
4875-M
4938-M

Cable
Range
(Inches)

Catalog Number
Cord Grip
Only

Catalog Number
Cord Grip
with Mesh

–

11/4
11/4
11/4
11/4
11/4

.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375

CGP
CGP
CGP
CGP
CGP

5875
51000
51125
51250
51375

11/2
11/2
11/2
11/2
11/2
11/2

.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.312-1.438

CGP 6875
CGP 61000
CGP 61125
CGP 61250
CGP 61375
CGP61438

CGP 61000-M
CGP 61125-M
CGP 61250-M
CGP 61375-M
CGP61438-M

2
2
2
2

1.250-1.375
1.438-1.562
1.562-1.688
1.688-1.812

CGP
CGP
CGP
CGP

CGP 81562-M
CGP 81688-M
CGP 81812-M

CGP
CGP
CGP
CGP

51000-M
51125-M
51250-M
51375-M

–

11A–21

Conduit
Size
(Inches)

–

81250
81562
81688
81812

Dimension Table (Straight Body)
NUT
BODY

WASHER

BUSHING

Dimensions (Inches)
Conduit Size

A

B

C

D

E

F

/2

0.58

0.53

0.72

1.81

1.09

1.33

1

A

E

F

B

C

3

/4

0.81

0.56

0.86

2.06

1.38

1.52

1

1.00

0.62

0.97

2.31

1.56

1.70

11/4

1.31

0.69

1.25

2.78

2.16

2.50

11/2

1.50

0.69

1.25

2.78

2.16

2.50

2

1.84

0.84

1.72

3.75

2.83

3.25

D

*Not UL listed

333
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 334

Cord Grip Fittings (90 Degree Body)
Note:
Consult factory for alternate materials (i.e., stainless
steel)

Features/Benefits:
• Aluminum body and nut for exceptional
corrosion resistance
• Tapered rubber bushing (grommet) provides
raintight, dust-tight seal and provides resistance to
cutting oils, age hardening, compression set and
normal temperature extremes
• Anti-friction washer is supplied between the nut
and bushing for ease in compression
• Machine cut threads prevent cross threading,
ensure smooth compression and watertight
make-up in conduit hubs
• Mesh option available in most sizes for
additional support
Applications:
For terminating cable in conduit hubs or knock-outs and for
providing relief from strain on cable
Certifications:

CGP (90 Degree Body)
Conduit
Size
(Inches)

Cable
Range
(Inches)

/2
/2
1
/2
1
/2
1
/2
1
/2
1
/2
1
/2

.125-.188
.188-.250
.250-.312
.312-.375
.375-.438
.438-.500
.500-.562
.562-.625

CGP
CGP
CGP
CGP
CGP
CGP
CGP
CGP

92188*
92250
92312
92375
92438
92500
92562
92625

CGP
CGP
CGP
CGP
CGP
CGP
CGP

92250-M
92312-M
92375-M
92438-M
92500-M
92562-M
92625-M

/4
/4
3
/4
3
/4
3
/4

.438-.562
.500-.625
.562-.688
.625-.750
.688-.812

CGP
CGP
CGP
CGP
CGP

93562
93625
93688
93725
93812

CGP
CGP
CGP
CGP
CGP

93562-M
93625-M
93688-M
93725-M
93812-M

1
1

3
3

11A–22

1
1
1
1
1
1
1

Catalog Number
Cord Grip
Only

.438-.562
.500-.625
.562-.688
.625-.750
.688-.812
.750-.875
.812-.938

CGP
CGP
CGP
CGP
CGP
CGP
CGP

94562
94625
94688
94750
94812
94875
94938

Catalog Number
Cord Grip
with Mesh

Conduit
Size
(Inches)

–

11/4
11/4
11/4
11/4
11/4

.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375

CGP
CGP
CGP
CGP
CGP

11/2
11/2
11/2
11/2
11/2
11/2

.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.312-1.438

CGP 96875
CGP 961000
CGP 961125
CGP 961250
CGP 961375
CGP961438

CGP 961000-M
CGP 961125-M
CGP 961250-M
CGP 961375-M
CGP961438-M

2
2
2
2

1.250-1.375
1.438-1.562
1.562-1.688
1.688-1.812

CGP
CGP
CGP
CGP

CGP 981562-M
CGP 981688-M
CGP 981812-M

CGP
CGP
CGP
CGP
CGP
CGP
CGP

94562-M
94625-M
94688-M
94750-M
94812-M
94875-M
94938-M

Cable
Range
(Inches)

Catalog Number
Cord Grip
Only

Catalog Number
Cord Grip
with Mesh

–

95875
951000
951125
951250
951375

CGP
CGP
CGP
CGP

951000-M
951125-M
951250-M
951375-M

–

–

981250
981562
981688
981812

Dimension Table (90 Degree Body)
Dimensions (Inches)

A

Conduit Size

A

B

C

D

E

F

G

/2

0.58

0.56

1.88

2.39

1.03

1.33

1.50

3

/4

0.76

0.63

2.25

2.88

1.25

1.52

1.94

1

1

0.99

0.63

2.41

3.13

1.44

1.70

2.00

11/4

1.28

0.69

3.19

4.41

2.13

2.55

2.69

11/2

1.40

0.69

3.19

4.41

2.13

2.55

2.69

2

1.90

0.81

4.03

5.56

2.81

3.25

3.19

E

D
C
B

G

F

*Not UL listed

334
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 335

Cable Grip Fittings

Features/Benefits:
• Neoprene bushing provides raintight seal
• Smooth bored for passage of the cable straight into the
metal clad equipment or through a bulkhead

Note:
Provides cable support for multiple conductor and/or large
single conductor cables entering metal cabinets or passage
through metal plates, switchgear, etc.

Application:
For terminating cable in all locations

To Order:
Select fitting based on diameter of cable

Catalog
Number

Dimensions (Inches)
C
Conduit
Size

D
Fitting
O.D.

E
Overall
Length

G
Ship Wt.
(Lbs.)

CG 138-15
CG 155-15

1.28
1.38

1.38
1.55

1 1/2
1 1/2

2 7/8
2 7/8

3 1/4
3 1/4

2 1/2
2 1/2

1
1

CG 174-20
CG 188-20
CG 195-20

1.54
1.66
1.73

1.74
1.88
1.95

2
2
2

3 1/4
3 1/4
3 1/4

4
4
4

3
3
3

1 1/4
1 1/4
1 1/4

CG 219-25
CG 236-25

1.95
2.16

2.19
2.36

2 1/2
2 1/2

4
4

4 1/2
4 1/2

3 3/8
3 3/8

2
2

CG 263-30
CG 280-30
CG 296-30

2.35
2.61
2.74

2.63
2.80
2.96

3
3
3

4 13/16
4 13/16
4 13/16

4 7/8
4 7/8
4 7/8

3 3/4
3 3/4
3 3/4

3
3
3

CG
CG
CG
CG

297-35
311-35
327-35
343-35

2.74
2.94
3.09
3.20

2.97
3.11
3.27
3.43

3
3
3
3

5
5
5
5

5
5
5
5

4
4
4
4

3
3
3
3

CG 364-40
CG 369-40
CG 387-40

3.31
3.52
3.64

3.64
3.69
3.87

4
4
4

/2
/2
1
/2
1
/2
1
1

/16
/16
3
/16
3
/16
3
3

5 13/16
5 3/16
5 3/16

/4
/4
1
/4
1
/4
1
1

5 3/8
5 3/8
5 3/8

/8
/8
1
/8
1
/8
1
1

4 3/16
4 3/16
4 3/16

/4
/4
3
/4
3
/4
3
3

4 1/4
4 1/4
4 1/4

11A–23

A
Dia. Over Jacket
Min.
Max.

E
G

D

A

C = THREAD

335
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 336

Boots – Protective Covering For AC Type Fittings

Because of superior holding strength, AC fittings are
sometimes used with jacketed cables in wet or
contaminated areas. For these applications, boots are
available.
End fitting clamping is made on the bare armor and the
boot protects the fitting and exposed cable armor. Boots
are used on cable splice entrance fittings and AC or ACS
type terminations.
Application:
Protects AC fittings in wet or contaminated areas

To Install:
Measure O.D. over jacket. Turn boot inside out and cut to
diameter 1/4” less than measured O.D. Leaving boot inside
out, push back over cable. Install fitting with jacket removed
as shown. Tighten clamp. Pull boot into place snapping
rim around flange of fitting. Tighten locknut and, if desired,
apply wrap of PVC tape around junction of jacket and boot.
To Order:
Select boot based on selected AC fitting (see page 11A–19
for AC fittings)

Note:
50 piece minimum

Dimensions (Inches)
Catalog
Number
BT3
BT15
BT20
BT25
BT30
BT35
BT40
BT50

For Use
With Fitting
Catalog Number
AC
AC
AC
AC
AC
AC
AC
AC

6-8
10-14
16-18
20-22
24-28
30-34
36
38-48

A
5
5
6
7
7
7
8
8

B

/2
/4
1
/2

/16
/16
1 5/16
1 7/8
2
2 5/8
3 3/16
3 3/8

1

11

1

1

/2

1

/2

13

C
1
1
2
2
3
4
4
5

D

/8
/8
3
/8
7
/8
1
/2

2
2
3
3
4
4
5
6

1
5

1
9

/2
/16

/2
/2
1
/4
5
/8
1
/4
1
/2
1
/4
5
/8
1
1

Ship Wt.
(Ozs.)
5
5
7
8
10
12
13
15

11A–24

B

PVC TAPE

A
D

C

BT neoprene boot
installed on Type AC
fitting to provide
moisture and
corrosion protection

336
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 337

Flange Supports for Cable Connector Fittings

Features/Benefits:
• Flanges complete with hardware and gaskets
• Copper free aluminum alloy for excellent corrosion
resistance
• Provides threaded hub for terminators

FS
Cat. No.

Application:
For added support on switchgear or entrances to
metallic enclosures
Notes:
• For use with JAG, AC(S) and CG
• For blind tap, use suffix L

FS5
Cat. No.

Conduit
Size
(Inches)

Ship Wt.
(Lbs.)

FS20

–

2

2 3/4

FS25

FS525

2 1/2

2 3/4

FS30

FS530

3

2 3/4

FS35

FS535

3 1/2

2 3/4

FS40

FS540

4

2 3/4

FS50

–

5

2 3/4

*FS60L

–

6

2 3/4

11A–25

*Available in blind tap only

FS5 for JAG, AC(S) and CG

FS for JAG, AC(S) and CG

CONDUIT SIZE
CONDUIT SIZE

1

7 /4 DIA.

73/8 SQ.

31/4

7/16

31/4

3 1/16

7/16

7/16” DIA.
8 HOLES

9

/16” DIA.
6 HOLES

TYPE FS STYLE

TYPE FS5 STYLE

337
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 338

Brackets

Features/Benefits:
• Aluminum alloy for excellent corrosion resistance
• Provide rigid support and effectively prevent movement of
cables at termination point
B

Applications:
For mounting of connectors and terminators on walls,
ceilings or structures.

A

Type BAC Brackets provide convenient means for installing
and terminating armored cable inside switchgear and control
compartments. They may also be used to terminate cable
parallel to wall, ceiling, or other surfaces, when desired.

E
F
D1

H

Certification:
D2

Note:
For use with all Adalet Fittings

C

To Order:
Order BAC based on conduit size of the fittings to be used

Dimensions (Inches)

11A–26

A
Conduit
Size

B

Catalog
Number

C

BAC12
BAC15
BAC20
BAC25

1 1/4
1 1/2
2
2 1/2

4
4
4 1/8
5

3
3
4
4

1

BAC30
BAC35
BAC40
BAC50
BAC60

3
3 1/2
4
5
6

5
6
6
7
9

5
5
6
7
9

1

1

D

E

D2

F

H
Ship Wt.
(Lbs.)

/8
/8
1
/2
9
/16
1
/4
5
1

/2
/2
1
/8
1
/2

2
2
3
3

3

/8
/8
1
/2
1
/2
1
/8

4
4
4
5
7

3

1

5

/4
/4
5
/16
3
/4

2
2
3
3

3

/8
/8
5
/8
1
/2
1
/8

4
4
5
6
8

3

3

7

/4
/4
5
/16
3
/4

2 3/4
2 3/4
3
3 1/4

/16
/16
1 1/2
1 1/2

/8
/8
5
/8
5
/8
1
/4

3
3
4
4
6

1
2
3
3
4

3

7

/16
/16
1
/2
3
/4
9

13

17
17

3

/4

/32
/32
9
/32
9
/32

2
2
2
2 1/2

/32
/32
11
/32
11
/32
11
/32

3
3 1/2
3 1/2
4
6

9
9

9

11

/8
/8
1
/2
1
3

338
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 339

Flanged Angle Adapter for Metal Clad Terminators
Features/Benefits:
• Terminate armor at a 45˚ angle and permit bending single
conductors in a reduced space
• Adapters are supplied complete with gaskets and fasteners
• Aluminum alloy for excellent corrosion resistance
Application:
For angle mounting of connectors and terminators to boxes
and equipment
Certification:
Note:
Type TFA Terminating Fitting Adapters are designed for use
with Type AC, ACS, or JAG fittings in conduit sizes from
2 1/2” to 6”
To Order:
Base selection on fitting conduit size from Column C of fitting
catalog page

Dimensions (Inches)
Catalog
Number

A
Length

B
Width

C
Height

2 1/2
3
3 1/2
4
5
6

8 3/4
10
10 1/2
11 1/4
13 5/16
15 7/16

6 1/2
6 3/4
7 5/8
8 1/8
9 3/4
11 1/8

3
4
4
4
5
6

/16
/4
3
/8
3
/4
7
/8
3
/4
9
1

D
2
2
3
3
2
3

E

/16
/16
3
/8
5
/8
5
/16
3
/8

3
3
3
3
3
3

13
15

Ship Wt.
(Lbs.)
/16

3
3 1/2
3 3/4
4
5 1/2
9

15

/16
/16
1
/16
5
/8
3
7

11A–27

TFA45-25
TFA45-30
TFA45-35
TFA45-40
TFA45-50
TFA45-60

For Fittings
Having
Conduit Size

D
D
D

D

D

D

E
3

/8 -16 x 1 1/4
HEX BOLT

D
E

E
3

/8 -16 x 1 1/4
HEX BOLT

E
3

/8 -16 x 1 1/4
HEX BOLT

E

TFA45-25

E

E

E

E

TFA45-30
TFA45-35
TFA45-40

TFA45-50
TFA45-60

339
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 340

Conduit Ventilating Cable Supports

Features/Benefits:
• Helps reduce temperatures in conduit, improving service
life and load carrying capacity of the cable
• Neoprene packing gland provides watertight seal and
cable support
• Set screws secure the ventilator to conduit

Note:
Type CV Supports are designed for use at top of conduit
where cable extends into air
To
1.
2.
3.

Application:
For supporting and sealing cable risers and allowing escape
of heated air from conduit

Order:
Select catalog number of fitting
Indicate number and diameter of cables
Where used with interlocked armored cable, specify
whether gasket to fit over jacket or over armor

Dimensions (Inches)
Catalog
Number

A*
Conduit
Size

B
Max. Cable O.D.
1-3/C
3-1/C**

C

D
Ship Wt.
(Lbs.)

CV20
CV25
CV30

2
2 1/2
3

1.60
1.91
2.37

.74
.93
1.19

4 11/16
5 5/32
5 13/16

2 5/8
2 5/8
2 3/4

2 1/2
2 1/2
3

CV35
CV40
CV50
CV60

3 1/2
4
5
6

2.75
3.12
3.82
4.42

1.41
1.63
2.13
2.55

6
6
8
9

2
2
3
3

3 1/2
4
5
6

/16
/16
1
/8
5
/8
3

13

/4
/8
3
/8
3
/4
3
7

* Metallic conduit - fitting can be adapted for other materials
** Additional holes can be supplied - consult factory

11A–28
C
ILLUSTRATING
MULTI-CONDUCTOR ENTRANCE

D

IR

A

IR

A

A

340
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 341

Bottom Conduit Ventilators
Features/Benefits:
• Castings are aluminum, anodized and Teflon sealed for maximum corrosion
resistance
• Helps reduce temperature in conduit riser, improving service life and load
carrying capacity of the cable
Application:
Used in conduit system to allow air to enter conduit riser

Dimensions (Inches)
A
Conduit
Size*

Catalog
Number
BCV
BCV
BCV
BCV
BCV
BCV
BCV

20
25
30
35
40
50
60

C

D
Ship Wt.
(Lbs.)

2
2 1/2
3
3 1/2
4
5
6

3
5
5
6
6
8
9

/8
/8
9
/16
1
/8
1
/2
1
/4
5
/16
5
1

2
4
4
4
4
4
5

7

/8

2
3
3 1/2
4
4
6
8

/4
/2
1
/2
7
/8
1
/4
1
1

11A–29

* Metallic conduit. Fitting can be adapted for other types.

R

D

AIR

AI

AIR

AIR

A

C

341
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:28 AM Page 342

Split Conduit Ventilating Cable Supports
Feature/Benefit:
• Split to permit insulation after cable has been pulled or where cable extends
some distance from ventilator mounting
Application:
Used where existing XLP or EPR cables are installed in conduit
Note:
For installation after pulling cable
To Order:
1. Select catalog number of fitting
2. Indicate number and diameter of cables
3. Where used with interlocked armored cable, specify whether gasket to fit over
jacket or over armor

Dimensions (Inches)
Catalog
Number
CVS
CVS
CVS
CVS
CVS
CVS
CVS

20
25
30
35
40
50
60

A
Conduit
Size*
2
2 1/2
3
3 1/2
4
5
6

B
Max. Cable O.D.

C

1-3/C

3-1/C**

1.50
1.80
2.23
2.60
2.92
3.68
4.42

.54
.75
1.00
1.25
1.44
1.87
2.18

D
Ship Wt.
(Lbs.)

4
5
5
6
6
7
9

/8
/4
3
/4
1
/8
3
/4
3
/4

2
2
2
2
2
2
2

5
1

/8
/8
3
/8
5
/8
5
/8
3
/4
3
/4

2
2
3
3 1/2
4
5
6

3
3

* Metallic conduit - fitting can be adapted for other materials
** Additional hole can be supplied - consult factory

11A–30

C

B

D

A

342
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 343

Splicing Kits
For Use on Solid Dielectric Cable 600 V to 35 kV 100%
Kits include all tapes, braids, abrasive cloth, instructions (connectors not included) for one straight splice of 1/C or 3/C cable.
Notes
• Catalog system provides five kits to cover most sizes from #8 AWG through 1000 MCM. Suffix provides
voltage information.
• For aluminum conductors or other than straight two way splices, see other options available.
• Splice kits are designed for cables having standard insulation thickness and concentric strand conductors. Consult factory
if insulation or stranding differs.
• Reference on connectors indicate splice design. Connectors also available.
• Kits suitable for tapered high voltage compression or solder connectors to standard TD-160 (not furnished).
To Order
Select catalog number not to exceed maximum conductor size shown. Add voltage suffix.
Examples
• 3/C 1/0 AWG copper 5 kV unshielded XLP – CATALOG #3SB-5 1/C 350 MCM copper cable. 175 XLP insulation 15kV 100%
– CATALOG #SC-15.
• 3/C 4/0 Aluminum 15kV 133%, T splice – CATALOG #3SB-16AT 1/C 600 MCM Aluminum cable. EPR insulation,
3-way-Y-35kV 100% – CATALOG #SD35AY.

Catalog Number
1/C
3/C

Maximum
Conductor Size

SA
SB
SC
SD
SE

# 1AWG
250 MCM
500 MCM
750 MCM
1000 MCM

3SA
3SB
3SC
3SD
3SE

PVC TAPE

3/C TAPERED
COMPRESSION
CONNECTOR SHOWN
IN DRAWING

CABLE
INSULATION
SPLICING TAPE

Voltage Suffix for Catalog Number
SEMI-CON TAPE

Shielded &
Unshielded

5

Unshielded

8
15
16
25
35

Shielded
Shielded
Shielded
Shielded
Shielded

SHIELDING BRAID

Voltage (kV)

11A–31

Catalog
Suffix No.

600V – 5kV 100%
5 kV – 8kV 100%
8 kV 133% – 15 kV 100%
15 kV 133%
16 kV – 25 kV 100%
26 kV – 35 kV 100%

CABLE SEMI-CON
SOLDER BLOCK

CABLE SHIELD
GROUNDING BRAID
CABLE JACKET

Other Types Available
Suffix

Application

A
AT
AY
T

Aluminum Conductor–2 way tapered connector
Aluminum Conductor–3 way-T-tapered connector
Aluminum Conductor–3 way-Y-tapered connector
Copper–3 way-T-solder connector to TD-160

TC
YC
X
Y

Copper–3
Copper–3
Copper–4
Copper–3

way-T-tapered compression connector
way-Y-tapered compression connector
way-solder full duplex TD-160
way-solder half duplex to TD-160

343
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 344

Splicing Kits
For Splicing PILC
Complete materials, instructions, and detailed drawings for making a correctly designed straight splice in varnished
cambric or paper-insulated cable are provided. (Connectors available separately.)
Notes
• Splice kits are designed for cables with standard cable insulations and concentric strand. Consult factory for kits
varying from standard construction.
• Kits are designed to be used with tapered compression or solder connectors (not furnished).
See page 11A–15 to order.
• For larger sizes, higher voltage, X or Y splices, or non-standard dimensions, consult factory.
To Order
Select catalog number for conductor size and voltage. Provide full cable description and dimensions with order.
Example
3/C 350 MCM Copper PILC 15 kV 133% insulation Catalog Number: 3LPC 16

Catalog Number
1/C
3/C
LPA
LPB
LPC
LPD
LPE

Maximum
Conductor Size

3LPA
3LPB
3LPC
3LPD
3LPE

250
500
750
1000

LEAD
WIPE

#1
MCM
MCM
MCM
MCM

CABLE
INSULATION

FILLING
COMPOUND
BINDING
TAPE

E
LEAD SLEEVE

SPLICING
TAPE

Voltage Suffix for Catalog Number
Catalog
Suffix No.

SHIPPING
TAPE

Shielded &
Unshielded

5
8
15
16
25
35

Voltage (kV)

Unshielded

600V – 5kV 100%

Shielded
Shielded
Shielded
Shielded
Shielded

5 kV – 8kV 100%
8 kV 133% – 15 kV 100%
15 kV 133%
16 kV – 25 kV 100%
26 kV – 35 kV 100%

CABLE
SHIELD

LEAD
JACKET
D

11A–32

Other Suffixes Also Available
Suffix
X
Y

Application
Copper – 4-way solder full duplex to TD160
Copper – 3-way solder half duplex to TD160

Three Conductor (Copper) Dimensional Data

One Conductor (Copper) Dimensional Data
Dimensions (Inches)

Catalog No.
LPA
LPB
LPC
LPD
LPE

5kV - 8kV
D
E
1 1/2
2
2 1/2
2 1/2
3

13
13 1/2
14
14 1/2
15 1/2

Shielded
15kV - 100%
D
E
2
2
2 1/2
3
3

15 1/2
16
16 1/2
17
18

Dimensions (Inches)
Shielded
15kV - 133%
D
E
2
2 1/2
3
3
3 1/2

Catalog No.
3
3
3
3
3

21
21 1/2
22
22 1/2
23 1/2

LPA
LPB
LPC
LPD
LPE

Belted
5kV - 8kV
D
E
3
3 1/2
4 1/2
5
5 1/2

18 1/2
20
21 1/2
22
24

Shielded
15kV - 100%
D
E
3 1/2
4 1/2
5
5 1/2
6

21
22 1/2
24
24 1/2
26

Shielded
15kV - 133%
D
E
4
4 1/2
5 1/2
6
6 1/2

24 1/2
26
27 1/2
28
30

344
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 345

Type 3AS Splicing Kits
For Splicing Metal Clad Cable 600 V to 35 kV
Kits complete for three copper conductors, jacketed MC cables. Designed for tapered compression or solder
connectors. Connectors not included. Aluminum conductor kits available. 3-way or 4-way kits available. Aluminum casings
furnished (steel and bronze casings and bronze end castings are available).
Notes
• Consult factory for connectors required for 3-way or 4-way splices.
• Standard design includes taping cone entrances.
• Compound included. If not desired, specify “less compound” on order and jacketing tapes will be furnished at same
price. Complete cable description is required with order.
• Reference on connectors indicates splice design. Connectors NOT included.
• Order within range of conductor sizes. 3/C #8 through 3/C #1 use 3ASA kit.
• Splice kits are designed for cables having standard insulation thickness and concentric strand conductors. Consult factory
if insulation or stranding differs.
• Kits suitable for tapered high voltage compression or solder connectors to standard TD-160 (not furnished).
To Order
Select catalog number for conductor size and add voltage suffix.
Examples
• Typical 3/C 500MCM copper 15 kV 100% insulation – CATALOG #3ASC15 (Provide O.D. over jacket and over armor with
order)
• Above cable Y or 3-way splice – CATALOG #3ASC-15Y
• Above cable – straight splice, armor clamps, no compound – CATALOG #3ASC-15-4 entrance both ends, less compound
Copper Conductor
Dimensions (Inches)

Conductor Size

Unshielded
2300 - 5kV
D
E

Shielded
5kV - 8kV 100%
D
E

Shielded
8kV - 133% - 15kV 100%
D
E

Shielded
15kV 133%
D
E

3 ASA
3 ASB
3 ASC

#1
250 MCM
500 MCM

3 1/2
3 1/2
4

26
26
28

3 1/2
4
5

26
29
29

3 1/2
3 1/2
5

29
32
33

3 1/2
4
5

33
33
41

4
5
5

33
41
41

3 ASD
3 ASE

750 MCM
1000 MCM

5
5

29
31

5
6

30
35

5
6

33
41

5
6

41
41

6
6

41
41

11A–33

Catalog No.

Unshielded
600 - 1kV
D
E

Voltage Suffix for Catalog Number
Catalog
Suffix No.
1
5
8
15
16
25
35

Shielded &
Unshielded

Voltage (kV)

Unshielded
Unshielded

600V – 1kV 100%
2300V – 5kV 100%

Shielded
Shielded
Shielded
Shielded
Shielded

5 kV 133% – 8kV 100%
8 kV 133% – 15 kV 100%
15 kV 133%
16 kV 100% – 25 kV 133%
26 kV 100% – 35 kV 100%

TYPICAL SPLICING KIT FOR 15kV CABLE

Other Suffixes Also Available
Suffix
A
AT

Application
Aluminum Conductor – 2 way tapered connector
Aluminum Conductor–3 way - T-tapered connector

345
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 346

Insulating Compounds for Splices, Potheads, Encapsulating
Type OI Compound
A medium soft, oil-insoluble, resin-base compound for applications where migration of cable oils may be a problem.
Type 3000 Oil
Type 3000 Oil is used for filling cable accessories where ambient temperatures do not fall below 32˚F. It is also used to
exclude air between layers of varnished cambric or paper tapes.

Physical and Electrical Properties
Property

Unit

OI

3000

˚F
˚F
˚F
˚F
˚F
–

490
545
133
356
.0006
1.13

350
395
–
266
–
.88

Volts
Per
Mil

830
586
444
–

–
–
–
350

Power Factor .050 gap at 60 cycle
185˚F
212˚F

%
–

13.0
–

–
.1

Normal State

–

Med. Soft

–

Container Size

Net Wt. (Lbs.)

Flash Point
Fire Point
Softening Point
Pouring Temp (max.)
Coefficient of Expansion
Specific Gravity at 77˚F
Dielectric Strength
.050” gap 86˚F
.050” gap 140˚F
.050” gap 194˚F
.1” gap 77˚F

Compound

11A–34

OI
OI
OI
OI

Catalog No.

Compound
Compound
Compound
Compound

3000
3000
3000
3000
3000

Flushing
Flushing
Flushing
Flushing
Flushing

OI-32
OI-128
OI-256
OI-640
Oil
Oil
Oil
Oil
Oil

3000-8
3000-16
3000-32
3000-128
3000-640

1
1
2
5

quart
gallon
gallons
gallons

2
8
16
40

1

3

/2 pint
1
1
1
5

pint
quart
gallon
gallons

/4

1 1/2
2 1/4
8
40

Thermometer for Compound Temperature Control
Thermometer has 1 1/2” diameter dial, with 50˚F to 500˚F temperature range, 8” stainless steel
stem and adjustable clip for supporting thermometer. Used for determining proper pouring
temperature of filling compounds and flushing oils.
Catalog No. GT-100F5-50-8

346
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 347

Cable Stripping Tools – Square Cut End of Cable Insulation
Tool and Bushing Selection

Conductor
Size

Bushing Range
Over Insulation Dia.
Min.
Max.

Tool Catalog
Number

#6-3/0
4/0-500
550-1000

1 SQ
2 SQ
3 SQ

.375
.766
1.109

1.125
1.469
1.812

Extra Bushing
Catalog Number

Replacement Blades
Catalog Number

1-S
2-S
3-S

B-1
B-1
B-1

Note
The Type SQ tool is designed to remove insulations such as PVC, cross-lined polyethylene, EPR or high molecular
polyethylene on round conductors. It is NOT recommended for use on rubber, butyl, VC or paper insulations.

INSULATION

Bushing Size for SQ and PT Tools
.625
.640
.656
.671

.875
.890
.906
.921

1.125
1.140
1.156
1.171

1.375
1.390
1.406
1.421

1.625
1.640
1.656
1.671

.437
.453
.468
.484

.687
.703
.718
.734

.937
.953
.968
.984

1.187
1.203
1.218
1.234

1.437
1.453
1.468
1.484

1.687
1.703
1.718
1.734

.500
.515
.531
.546

.750
.765
.781
.796

1.000
1.015
1.031
1.046

1.250
1.265
1.281
1.296

1.500
1.515
1.531
1.546

1.750
1.781
1.796
1.812

.562
.578
.593
.609

.812
.828
.843
.859

1.062
1.078
1.093
1.109

1.312
1.328
1.343
1.359

1.562
1.578
1.593
1.609

CONDUCTING
JACKET OR
SHIELD

BUSHING
FOR THIS
DIAMETER

TOOL CATALOG
NUMBER FOR
CONDUCTOR SIZE

11A–35

.375
.390
.406
.421

To Order
1. Select tool for conductor size.
2. Diameter over insulation – after semiconducting jacket is removed – must be provided with order.
3. Tool will include two bushings – one based on nearest O.D., the other to accommodate oversize insulation.
4. To obtain additional bushings order size 1S for tool 1SQ, 2S for tool 2SQ, or 3S for tool 3SQ plus diameter from
above chart. Then make sure the bushing size fits the available range for the tool.

347
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 348

Cable Insulation Penciling Tools

For preparing cable splices and terminations with savings in time and labor.
PT tools are built to guide on the cable connector. Because of close tolerance they will work only on standard
stranding indicated below. Tools may be used on XLP, polyethylene, or EPR insulation on voltage range 5 kV 100%
through 25 kV 100%.
Note
For intermediate or special sizes or stranding consult factory for price and delivery.
To Order
1. Select tool for conductor size. Diameter over insulation – after semiconducting jacket is removed – must be
provided with order.
2. Tool will include two bushings – one based on nearest O.D., the other to accommodate oversize insulation – plus
one extra blade.
3. To obtain additional bushings, order B bushing for suffix “B” tool, C bushing for suffix “C” tool, D bushing for suffix
“D” tool, plus diameter from chart below. Then make sure the bushing size fits the available range for the tool.
4. For extra blades order the correct blade for tool size as noted in the chart.

Tool and Bushing Selection
Conductor Size Left Hand Lay Standard
Strand Concentric Round

Catalog No.
PT 8B
PT 6B
PT 4B
PT 2B
PT 1B
PT 10B
PT 20B
PT 30B

8- 7-Strand
6- 7-Strand
4- 7-Strand
2- 7-Strand
1- 19-Strand
1/0- 19-Strand
2/0- 19-Strand
3/0- 19-Strand

PT 40C

4/0- 19-Strand

Catalog No.

Conductor Size Left Hand Lay Standard
Strand Concentric Round

PT
PT
PT
PT
PT

250C
300C
350C
400C
500C

250-37-Strand
300-37-Strand
350-37-Strand
400-37-Strand
500-37-Strand

PT 600D
PT 700D
PT 750D
PT 1000D

600-61-Strand
700-61-Strand
750-61-Strand
1000-61-Strand

11A–36

Suffix
INSULATION

Tool Ending
Suffix

Bushing Size Range
for B, C, or D tools

B
C
D

Min.

Max.

.375
.500
.625

1.062
1.330
1.745

CONDUCTING
JACKET OR
SHIELD

BUSHING
FOR THIS
DIAMETER

TOOL CATALOG
NUMBER FOR
CONDUCTOR SIZE

Replacement Parts
Bushing Size
B
C
D

Blade Size
.295B
.295C
.295D

348
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 349

Cable Accessories
High Voltage Insulating Tape
High voltage insulating tape used with rubber, cross-linked polyethylene, or EPR insulated cables for terminations or
splices up to 69 kV. Properly applied, tape is self amalgamating, providing waterproof seal for direct burial. Tape
will provide protection against corona even after repeated load cycles. Suitable for 130˚C emergency conditions.

Catalog
Number
THVT
THVT
THVT
THVT

3075
3010
3015
3020

Thickness

Length (Ft.)

.030
.030
.030
.030

30
30
30
30

Width (inches)
3

/4

Standard
Packaging Qty.
10
10
10
10

1
1 1/2
2

rolls
rolls
rolls
rolls

Semi Conducting Tape
.030 semi conducting EPR tape, self amalgamating. Used for shielding of high-voltage terminations and splices,
filling indents on compression connectors, or as a replacement of strand shields.

Catalog
Number
TSC-15

Thickness

Length (Ft.)

.030

15

Width (inches)
3

/4

Standard
Packaging Qty.
10 rolls

PVC All Weather Plastic Tape
.085 flame-retardant, weather-resistant, cold temperature tape. Resistant to sunlight, oil, acids, alkalis, and chemicals.
Suitable for low-voltage taping or outer jacketing on terminations and splices.

TPVC-20
TPVC-66

Thickness

Length (Ft.)

.085
.085

20
66

Width (inches)
3

/4
/4

Standard
Packaging Qty.
20 rolls
10 rolls

3

11A–37

Catalog
Number

Silicone Rubber Tape
.015 rectangular, unsupported, self-adhering, track resistant silicone tape used with terminations such as the FSD in
contaminated areas or salt atmospheres.

Catalog
Number
TSIL-30

Thickness

Length (Ft.)

.015

30

Width (inches)
3

/4

Standard
Packaging Qty.
10 rolls

Neoprene Jacketing Tape
.030 self-amalgamating jacket tape for protection of cable joints exposed to hydrocarbons. Also used for corrosion
protection on lead sleeves or splice cases.
Catalog
Number
TNJ-3075
TNJ-3010
TNJ-3015
TNJ-3020

Thickness

Length (Ft.)

.030
.030
.030
.030

30
30
30
30

Width (inches)
3

/4

Standard
Packaging Qty.
10
10
10
10

1
1 1/2
2

rolls
rolls
rolls
rolls

349
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 350

Cable Accessories
Arc Proofing Tape
Fire resistant tape used for arc proofing and fireproofing cables in manholes, cable trays, switchboxes and substations.
Catalog
Number

Length (Ft.)

TAP-2015
TAP-2030

20
20

Width (inches)

Standard
Packaging Qty.

1 1/2
3

10 rolls
5 rolls

Friction Tape
.015 cotton weave tape coated both sides with asphalt. Used for mechanical protection against abrasion, bare
wire, and to prevent mechanical damage.

Catalog
Number

Length (Ft.)

TFT-6575
TFT-6015
TFT-6020

60
60
60

Width (inches)

Standard
Packaging Qty.

3

/4

10 rolls
10 rolls
10 rolls

1 1/2
2

Varnished Dacron® Glass Tape
Dacron® glass tapes are composed of Dacron® yarn and glass fiber filling thread treated with an oleoresinous
varnish. These tapes may be used for splicing paper or varnished cambric and lead cables or for stress cones with
pothead terminations. Tapes are dry packed. .012 thickness.

Catalog
Number

Length (Yards)

TVD-1205
TVD-1275
TVD-5475
TVD-1210
TVD-4810

4
4
18
4
16

Width (inches)
1

/2
/4
3
/4
3

1
1

Standard
Packaging Qty.
100
100
10
100
10

rolls
rolls
rolls
rolls
rolls

11A–38

*Oil packed .012 X 4 yd. X 1/4, 1/2, 3/4, 1” rolls available. Consult factory.

Cotton Tape
Cotton Tape is one of the more versatile items required in splicing. It can be used to tie cables together, protect
insulation when soldering and in extra high-voltage applications, it is used to protect the entire splice and keep it
oiled during other operations.

Catalog
Number

Length (Yards)

Width (inches)

9

1

TCT-2705

/2

Standard
Packaging Qty.
50 rolls

Cotton Yarn
Cotton Yarn is utilized to fill the corners in a properly stepped paper insulated cable. These free untwisted
strands of pure cotton help to smooth the contour of these steps and effectively change them to a long, smooth
taper. This is necessary to provide a surface that can be easily taped with no voids in the corners. Dry packed.

Catalog
Number
TCY-8025

Length
(Feet)
80

Width (Lbs.)
1

/4

Standard
Packaging Qty.
50

350
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 351

Cable Accessories
Cleaning Kit for Extruded Dielectric Cables
Kit including aluminum oxide abrasive cloth, clean, lint-free rags, and non-chlorinated solvent designated for use in
cleaning cables. Each kit will clean three cables from #8 through 1000 MCM in voltage ranges up to 35 kV for
either termination or splicing.

Catalog
Number
PLCK-35

Standard
Packaging Qty.
10

Tinned Grounding Braid
Tinned copper grounding braid used for grounding terminations and splices.

Catalog
Number
TGB-10025
TGB-20025
TGB-10050

Length (Ft.)
100
200
100

Width (inches)
1

/4
1
/4
1
/2

Standard Strand
192/#36 (13 AWG)
192/#36 (13 AWG)
240/#30 (6 AWG)

Packaging Qty.
1
1
1

Tinned Shielding Braid
Tinned copper 1” tubular mesh for use with stress cones, terminations and splices.
Catalog
Number
TSB-15
TSB-100
TSB-432

Length (Ft.)

Packaging

15
100
432

Box
Spool
Spool

Standard
Packaging Qty.
20
1
1

11A–39

Bar Solder
Each bar is plainly marked as to its tin / lead content. 40/60 solder is recommended for sweating connectors and joints.
Catalog
Number
SB-4060

Content
(Tin/Lead)
38/62

Weight (Lbs.)
1

Standard
Packaging Qty.
50 Lbs.

351
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.11A part 2 12/9/01 11:29 AM Page 352

Cable Accessories
Wire Solder
Wire solder is supplied 1/8” diameter, solid. Wire solder is highly desirable for use in the tacking and joining of
shielding braid and ground strap.

Catalog
Number
SW-5050

Content
(Tin/Lead)

Weight (Lbs.)

50/50

1

Standard
Packaging Qty.
5 lbs.

Stearine Soldering Flux
An activated Stearic formula flux molded in easy-to-use wickless candle form. Its waxlike texture allows the
protection of areas prior to soldering by rubbing on a layer which will melt and clean the surface upon heating.
Used for wiping lead joints.

Catalog
Number

Form
SSF-2

Candle

Weight (Oz.)
2

Standard
Packaging Qty.
10

Rosin Based Soldering Flux
Non-conductive, non-corrosive flux paste for soldering of connectors, ground and shielding braid.
Brush Included.
Catalog
Number

Form
SSR

Paste

Can
Weight (Oz.)
2

Standard
Packaging Qty.
12

Miscellaneous Chemicals
11A–40

Catalog
Number
RC-1
PCL-2
PCL-32
PCL-128
SG-1

Description

Container

Standard
Packaging Qty.

A50P68 butyl base rubber cement
Non-Chlorinated cleaning solvent w/cloth
Non-Chlorinated cleaning solvent
Non-Chlorinated cleaning solvent
Silicone Grease

1-oz. tube
2-oz. jar
1-qt. can
1-gal. can
1/4-oz. tube

24
40
10
41
50

352
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.12 12/9/01 11:30 AM Page 353

Industry Standards and Definitions
North American Classification System
for Hazardous Locations

Three popular methods of protection which exist in North
America for hazardous electrical locations:
Type of Protection
1. Explosionproof

North American hazardous locations are categorized by three
criteria: Class - nature of hazardous substance present; Division
- frequency of presence; Group - specific type of hazardous
material.

Method of Protection
Containment

2. Increased Safety

Mechanical

3. Intrinsically Safe

Electrical

Class I

Potentially explosive gas or vapor

Class II

Potentially explosive dust

Class III

Potentially explosive fiber

Division 1

Potentially explosive substance present under
normal operating conditions

Division 2

Potentially explosive substance present under
abnormal operating conditions

HAZARDOUS (CLASSIFIED) LOCATIONS
or Selected Gases, Vapors and Dusts

Group B - Atmospheres
acrolein (inhibited) (2)
arsine
butadiene (1)
ethylene oxide (2)
hydrogen
manufactured gases containing
more than 30% H2 (by volume)
propylene oxide (2)
propylnitrate
Group C - Atmospheres
acetaldehyde
allyl alcohol
n-butyraldehyde
carbon monoxide
crotonaldehyde
cyclopropane
diethyl ether
diethylamine
epichlorohydrinnn
ethylene

ethylenimine
ethyl mercaptan
ethyl sulfide
hydrogen cyanide
hydrogen sulfide
morpholine
2-nitropropane
tetrahydrofuran
unsymmetrical dimethyl hydrazine
Group D - Atmospheres
acetic acid (glacial)
acetone
acrylonitrile
ammonia (3)
benzene
butane
1-butanol (butyl alcohol)
2-butanol (secondary butyl alcohol)
n-butyl acetate
isobutyl acetate
di-isobutylene
ethane
ethanol (ethyl alcohol)
ethyl acetate

ethyl acrylate (inhibited)
ethylene diamine (anhydrous)
ethylene dichloride
ethylene glycol monomethyl ether
gasoline
heptanes
hexanes
isoprene
isopropyl ether
mesityl oxide
methane (natural gas)
methanol (methyl alcohol)
3-methyl-1 butanol (isoamyl
alcohol)
methyl ethyl ketone
methyl isobutyl ketone
2-methyl-1-propanol (isobutyl
alcohol)
2-methyl-2-propanol (tertiary butyl
alcohol)
petroleum naphtha (4)
pyridine
octanes
pentanes
1-pentanol (amyl alcohol)

propane
1-propanol (propyl alcohol)
2-propanol (isopropyl alcohol)
propylene
styrene
toluene
vinyl acetate
vinyl chloride
xylenes
Group E - Atmospheres
containing metal dust, including
aluminum, magnesium, and their
commercial alloys, and other
metals of similarly hazardous
characteristics
Group F - Atmospheres
containing carbon black, coal or
coke dust
Group G - Atmospheres
containing flour, starch or grain
dust
Note: Carbon disulfide must be
treated in a special manner.

Example: An area where hydrogen was present under normal operating conditions would require a product suitable for Class I,
Division 1, Group B applications.

353
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

12A–1

Group A - Atmospheres
acetylene

15599 Sec.12 12/9/01 11:30 AM Page 354

Industry Standards and Definitions
NEMA Designation

Underwriters Laboratories Inc.
UL 50 and UL 508

Canadian Standards Association
CSA Standard C22.2 No 94

12A–2

Type 1

Indoor use to provide a degree of
protection against contact with the
enclosed equipment; in locations
where unusual service conditions
do not exist

Indoor use to provide a degree of
protection against contact with the
enclosed equipment and against a
limited amount of falling dirt

General purpose enclosure;
protects against accidental contact
with live parts

Type 2

Indoor use to provide a degree of
protection against contact with the
enclosed equipment and against
limited amounts of falling water and
dirt

Indoor use to provide a degree of
protection against limited amounts
of falling water and dirt

Drip proof enclosure same as
Type 1; indoor use to provide a
degree of protection against
dripping and light splashing of noncorrosive liquids and falling dirt

Type 3

Indoor or outdoor use to provide a
degree of protection against
windblown dust, rain and sleet;
undamaged by the formation of ice
on the enclosure (not sleet proof)

Indoor or outdoor use to provide a
degree of protection against
windblown dust, rain and sleet;
undamaged by the formation of ice
on the enclosure

Weatherproof enclosure; indoor or
outdoor use to provide a degree of
protection against rain, snow and
blown dust; undamaged by the
external formation of ice on the
enclosure

Type 3R

Indoor or outdoor use to provide a
degree of protection against falling
rain and sleet; undamaged by the
formation of ice on the enclosure

Indoor or outdoor use to provide a
degree of protection against falling
rain and sleet; undamaged by the
formation of ice on the enclosure

Weather proof enclosure; indoor or
outdoor use to provide a degree of
protection against rain or snow;
undamaged by the external
formation of ice on the enclosure
(CSA does not specify sleet resist)

Type 3S

Indoor or outdoor use to provide a
degree of protection against
windblown dust, rain and sleet;
provides for operation of external
mechanisms when ice laden

Indoor or outdoor use to provide a
degree of protection against
windblown dust, rain and sleet;
external mechanisms remain
operable while ice laden

Weather proof enclosure; indoor or
outdoor use to provide a degree of
protection against rain or snow;
undamaged by the external formation of ice on the enclosure surface
(CSA does not specify sleet proof)

Type 4

Indoor or outdoor use to protect the
enclosed equipment against
splashing water, seepage of water,
falling or hose-directed water, and
severe external condensation;
these enclosures are sleet resistant
but not sleet proof

Indoor or outdoor use to provide a
degree of protection against
splashing water, windblown dust
and rain, and hose directed water;
undamaged by the formation of ice
on the enclosure

Watertight enclosure; indoor or
outdoor use to provide a degree of
protection against rain, snow, blown
dust, splashing and hose directed
water; undamaged by the external
formation of ice on the enclosure

Type 4X Indoor or outdoor use to provide a
degree of protection against
corrosion, windblown dust and rain,
splashing water, and hose-directed
water; undamaged by the formation
of ice on the enclosure

Indoor or outdoor use to provide a
degree of protection against
splashing water, windblown dust
and rain, and hose directed water;
undamaged by the formation of ice
on the enclosure; resists corrosion

Watertight enclosure; indoor or
outdoor use to provide a degree of
protection against rain, snow, blown
dust, splashing and hose directed
water; undamaged by the external
formation of ice on the enclosure;
resists corrosion

Not typically used by UL.

Indoor use, so constructed that
dust, readily ignitable fibers or
combustible flyings cannot enter
the enclosure

Type 5

Indoor use to provide a degree of
protection against dust, falling dirt,
and dripping non-corrosive liquids

354
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.12 12/9/01 11:30 AM Page 355

Industry Standards and Definitions

NEMA Designation

Underwriters Laboratories Inc.
UL 50 and UL 508

Canadian Standards Association
CSA Standard C22.2 No 94

Type 6

Indoor or outdoor use to provide a
degree of protection against the
entry of water during occasional
temporary submersion at a limited
depth

Indoor or outdoor use to provide a
degree of protection against the
entry of water during temporary
submersion at a limited depth;
undamaged by the formation of ice
on the enclosure

No CSA equivalent

Type 6P

Indoor or outdoor use to provide a
degree of protection against the
entry of water during prolonged
submersion at a limited depth

Indoor or outdoor use to provide a
degree of protection against the
entry of water during prolonged
submersion at a limited depth

No CSA equivalent

Type 7

For use in indoor locations classified
as Class I, Groups A, B, C and D, as
defined in the National Electrical
Code

Not typically used by UL

Similar to NEMA designation; refer
to Canadian Electric Code
C22.1 Sec. 18 (C22.2 No. 30)

Type 8

For use in indoor or outdoor
locations classified as Class I,
Groups A, B, C and D, as defined in
the National Electrical Code – oil
immersed

Not typically used by UL

Similar to NEMA designation; refer
to Canadian Electric Code
C22.1 Sec. 18 (C22.2 No. 30)

Type 9

For use in indoor locations classified
as Class II, Groups E, F and G, as
defined in the National Electrical
Code

Not typically used by UL

Similar to NEMA designation dust
tight (hazardous dust); refer to
Canadian Electric Code C22.2 No. 25

Type 10

Mining enforcement safety
administration approved

Not typically used by UL

No CSA equivalent specified for
industrial control applications
(See C22.5 for use of electricity in
mines)

Type 11

Indoor use to provide, by oil
immersion, a degree of protection
to enclosed equipment against
corrosive effects of liquids and
gases

Indoor use to provide, by oil
immersion, a degree of protection
of the enclosed equipment against
corrosive effects of corrosive
liquids and gases

No CSA equivalent; similar to
Type 4

Indoor use to provide a degree of
protection against dust, falling dirt
and dripping non-corrosive liquids
No knockouts

Indoor use to provide a degree of
protection against dust, falling dirt
and dripping non-corrosive liquids
No knockouts

Indoor use to provide a degree of
protection against circulating dust,
lint, fibers, dripping and light
splashes of non-corrosive liquids

Indoor enclosure with knockouts to
provide a degree of protection
against dust, falling dirt and dripping
non-corrosive liquids other than at
knockouts

Indoor use to provide a degree of
protection against dust, falling dirt,
and dripping non-corrosive liquids
With knockouts

No CSA equivalent

Indoor use to provide a degree of
protection against dust and
spraying of water, oil and noncorrosive coolants

Indoor use to provide a degree of
protection against circulating dust,
lint, fibers, seepage and spraying of
non-corrosive liquids including oils
and coolants

12A–3

Type 12

Type 12K

Type 13
Indoor use to provide a degree of
protection against lint, dust,
seepage, external condensation and
spraying of water, oil and noncorrosive coolant

355
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.12 12/9/01 11:30 AM Page 356

Industry Standards and Definitions
EUROPEAN STANDARDS
Type of Protection

Method of Protection

CENELEC Designation

Flameproof Enclosure

Containment

‘d’

Increased Safety

Mechanical

‘e’

Intrinsically Safe

Electrical

‘i’

These designations are typically preceded by EEx, the designation indicating an apparatus built to a European standard.

European Classification of Hazardous Locations
Zone 0

Explosive gas present continuously

Zone 1

Explosive gas present occasionally under normal operating conditions

Zone 2

Explosive gas present for short period

Zone 20

Explosive dust present continuously

Zone 21

Explosive dust present occasionally under normal operating conditions

Zone 22

Explosive dust present for short period

Explosion Groups
Group I

Electrical equipment for mining applications

Group II

Electrical equipment for all remaining hazardous areas

Ingress Protection (IP rating) defines the degree of protection

Scope of Protection for the IP protection classes
First Digit
Digit

Second digit
Water protection

No protection

0

No protection

Protection against back
of hand contact

Protection against solid
foreign bodies
50 mm diameter

1

Protection against water
drops falling vertically

2

Protection against
finger contact

Protection against solid
foreign bodies
12.5 mm diameter

2

Protection against water
drops falling at
an angle (15°)

3

Protection against
contact from tools

Protection against solid
foreign bodies 2.5 mm diameter

3

Protection against waterspray at an angle up to 60°

4

Protection against
contact with a wire

Protection against solid
foreign bodies 1.0 mm diameter

4

Protection against waterspray from all directions

5

Protection against
contact with a wire

Protection against dust

5

Protection against water jets

6

Protection against
contact with a wire

Dust-tight

6

Protection against strong water jets

7

7

Protection against intermittent
immersion in water

8

8

Protection against continuous
immersion in water

Digit

Physical protection

Foreign body protection

0

No protection

1

12A–4
356

ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.12 12/9/01 11:30 AM Page 357

Industry Standards and Definitions
CLASSIFICATION BY GROUP AND
CATEGORY ACCORDING TO INTENDED USE
(Surface Industry)

Area

Category of
Equipment

Presence or Duration of
Explosive Atmosphere

Inflammable
Substances

Continuous Presence
1

Long Periods

Gas, Vapors,
Mist, Dust

Frequent

Equipment
Group II
(surface)

Level of Protection
Faults to Allow for

Comparison with
Present Practice

Very High Level of Protection

Group II
Zone 0 (gas)
Zone 20 (dust)

2 types of protection or
2 Independent faults

High Level of Protection
2

Likely to Occur

Gas, Vapors,
Mist, Dust

1 Type of Protection
Habitual frequent malfunction

Unlikely to Occur
Present for a Short Period

Gas, Vapors,
Mist, Dust

Normal Protection
Required Level of Protection

Group II
Zone 2 (gas)
Zone 22 (dust)

12A–5

3

Group II
Zone 1 (gas)
Zone 21 (dust)

357
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.12 12/9/01 11:30 AM Page 358

Industry Standards and Definitions

TEMPERATURE RATING
The maximum surface temperature of the exposed surface of electrical apparatus must always be lower than the ignition
temperature of the gas or vapor mixture.

Temperature Class

Maximum

Ignition Temperature

Surface Temperature

of Combustible Material

450 C
300 C
200 C
135 C
100 C
85 C

>450 C
>300 C
>200 C
>135 C
>100 C
>85 C

TI
T2
T3
T4
T5
T6

Safety characteristics of flammable gases and vapors
Ignition temperature °C

Acetaldehyde
Acetic acid
Acetic anhydride
Acetone
Acetylene
Ammonia
Amylacetate
Benzene
Benzol
Carbon disulfide
Carbon monoxide
Cyclohexene
1,2-Dichlorethane
Diesel fuel
Ethane
Ethylacetate
Ethylalcohol
Ethylchloride
Ethylene
Ethylenoxide
Ethylether
Ethyl glycol
Fuel oil
Hydrogen
Hydrogen disulfide
Methane
Methanol
Methyl chloride
n-Butane
n-Butylalcohol
n-Hexane
n-Propylalcohol
Naphthaline
Oleic acid
Phenol
Propane
Tetraline
Toluole

140
485
330
540
305
630
380
220
555
95
605
430
440
220 up to 300
515
460
425
510
425
440
180
235
220 up to 300
560
270
595 (650)
455
625
365
340
240
405
520
360
595
470
425
535

Temperature class
T4
T1
T2
T1

Explosion group
II
II
II
II

A
A
A
A

II
II
II
II

A
A
A
A

II
II
II
II
II
II
II
II

A
A
A
A
A
A
A
A

T2

IIC

T1
T2
T3
T1
T6
T1
T2
T2
T3
T1
T1
T2
T1

IIC

T2
T2

II B
II B
II B

T4
T3
T3

II B

II A

T1

IIC
T3

T1
T1
T1
T2
T2
T3

II B
II
II
II
II
II
II

A
A
A
A
A
A

T2
T1

II A
T2

T1
T1

II A
II A
T2

T1

II A

358
ADALET Enclosure Systems • Designing Our Products Around Yours

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

12A5

12A–6

Medium

15599 Index 12/10/01 5:28 PM Page 359

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

.295 B BLADES . . . . . . . . . . .11A

12MF-12-SS . . . . . . . . . . . . . .1C

3 ASC-5A . . . . . . . . . . . . . . .11A

3SB-15 . . . . . . . . . . . . . . . . .11A

.295 C BLADES . . . . . . . . . . .11A

12P10 . . . . . . . . . . . . . . . . . . .1C

3 ASC-5Y . . . . . . . . . . . . . . .11A

3SB-16 . . . . . . . . . . . . . . . . .11A

.295 D BLADES . . . . . . . . . .11A

12P12 . . . . . . . . . . . . . . . . . . .1C

3 ASC-8 . . . . . . . . . . . . . . . .11A

3SB-25 . . . . . . . . . . . . . . . . .11A

06P04 . . . . . . . . . . . . . . . . . . .1C

14P08 . . . . . . . . . . . . . . . . . . .1C

3 ASC-8A . . . . . . . . . . . . . . .11A

3SB-35 . . . . . . . . . . . . . . . . .11A

06P06 . . . . . . . . . . . . . . . . . . .1C

14P12 . . . . . . . . . . . . . . . . . . .1C

3 ASC-8Y . . . . . . . . . . . . . . .11A

3SB-5 . . . . . . . . . . . . . . . . . .11A

07-3323-1100/1000 . . . . . . . . .3D

16P14 . . . . . . . . . . . . . . . . . . .1C

3 ASD-1 . . . . . . . . . . . . . . . .11A

3SB-8 . . . . . . . . . . . . . . . . . .11A

07-3323-1100/2000 . . . . . . . . .3D

1-S BUSHING . . . . . . . . . . . .11A

3 ASD-15 . . . . . . . . . . . . . . .11A

3SC-15 . . . . . . . . . . . . . . . . .11A

07-3323-1100/3000 . . . . . . . . .3D

1-SQ . . . . . . . . . . . . . . . . . . .11A

3 ASD-15A . . . . . . . . . . . . . .11A

3SC-16 . . . . . . . . . . . . . . . . .11A

07-3323-1100/4000 . . . . . . . . .3D

2-S BUSHING . . . . . . . . . . . .11A

3 ASD-15Y . . . . . . . . . . . . . .11A

3SC-25 . . . . . . . . . . . . . . . . .11A

07-3323-1100/4100 . . . . . . . . .3D

2-SQ . . . . . . . . . . . . . . . . . . .11A

3 ASD-16 . . . . . . . . . . . . . . .11A

3SC-35 . . . . . . . . . . . . . . . . .11A

07-3323-1100/4200 . . . . . . . . .3D

3 ASA-1 . . . . . . . . . . . . . . . .11A

3 ASD-16A . . . . . . . . . . . . . .11A

3SC-5 . . . . . . . . . . . . . . . . . .11A

07-3323-1100/4300 . . . . . . . . .3D

3 ASA-15 . . . . . . . . . . . . . . .11A

3 ASD-16Y . . . . . . . . . . . . . .11A

3SC-8 . . . . . . . . . . . . . . . . . .11A

07-3323-1100/5000 . . . . . . . . .3D

3 ASA-15A . . . . . . . . . . . . . .11A

3 ASD-1A . . . . . . . . . . . . . . .11A

3SD-15 . . . . . . . . . . . . . . . . .11A

07-3323-1100/6000 . . . . . . . . .3D

3 ASA-15Y . . . . . . . . . . . . . .11A

3 ASD-1Y . . . . . . . . . . . . . . .11A

3SD-16 . . . . . . . . . . . . . . . . .11A

07-3323-1100/6100 . . . . . . . . .3D

3 ASA-16 . . . . . . . . . . . . . . .11A

3 ASD-5 . . . . . . . . . . . . . . . .11A

3SD-25 . . . . . . . . . . . . . . . . .11A

07-3323-1100/6200 . . . . . . . . .3D

3 ASA-16A . . . . . . . . . . . . . .11A

3 ASD-5A . . . . . . . . . . . . . . .11A

3SD-35 . . . . . . . . . . . . . . . . .11A

07-3323-1100/6300 . . . . . . . . .3D

3 ASA-16Y . . . . . . . . . . . . . .11A

3 ASD-5Y . . . . . . . . . . . . . . .11A

3SD-5 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/1000 . . . . . . . . .3D

3 ASA-1A . . . . . . . . . . . . . . .11A

3 ASD-8 . . . . . . . . . . . . . . . .11A

3SD-8 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/2000 . . . . . . . . .3D

3 ASA-1Y . . . . . . . . . . . . . . .11A

3 ASD-8A . . . . . . . . . . . . . . .11A

3SE-15 . . . . . . . . . . . . . . . . .11A

07-3323-1200/3000 . . . . . . . . .3D

3 ASA-5 . . . . . . . . . . . . . . . .11A

3 ASD-8Y . . . . . . . . . . . . . . .11A

3SE-16 . . . . . . . . . . . . . . . . .11A

07-3323-1200/4000 . . . . . . . . .3D

3 ASA-5A . . . . . . . . . . . . . . .11A

3 ASE . . . . . . . . . . . . . . . . . .11A

3SE-25 . . . . . . . . . . . . . . . . .11A

07-3323-1200/4100 . . . . . . . . .3D

3 ASA-5Y . . . . . . . . . . . . . . .11A

3 LPA-15 . . . . . . . . . . . . . . . .11A

3SE-35 . . . . . . . . . . . . . . . . .11A

07-3323-1200/4200 . . . . . . . . .3D

3 ASA-8 . . . . . . . . . . . . . . . .11A

3 LPA-16 . . . . . . . . . . . . . . . .11A

3SE-5 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/4300 . . . . . . . . .3D

3 ASA-8A . . . . . . . . . . . . . . .11A

3 LPA-5 . . . . . . . . . . . . . . . . .11A

3SE-8 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/5000 . . . . . . . . .3D

3 ASA-8Y . . . . . . . . . . . . . . .11A

3 LPA-8 . . . . . . . . . . . . . . . . .11A

3-SQ . . . . . . . . . . . . . . . . . . .11A

07-3323-1200/6000 . . . . . . . . .3D

3 ASB-1 . . . . . . . . . . . . . . . .11A

3 LPB-15 . . . . . . . . . . . . . . . .11A

AC-10 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/6100 . . . . . . . . .3D

3 ASB-15 . . . . . . . . . . . . . . .11A

3 LPB-16 . . . . . . . . . . . . . . . .11A

AC-12 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/6200 . . . . . . . . .3D

3 ASB-15A . . . . . . . . . . . . . .11A

3 LPB-5 . . . . . . . . . . . . . . . . .11A

AC-14 . . . . . . . . . . . . . . . . . .11A

07-3323-1200/6300 . . . . . . . . .3D

3 ASB-15Y . . . . . . . . . . . . . .11A

3 LPB-8 . . . . . . . . . . . . . . . . .11A

AC-16 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/1000 . . . . . . . . .3D

3 ASB-16 . . . . . . . . . . . . . . .11A

3 LPC-15 . . . . . . . . . . . . . . . .11A

AC-18 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/2000 . . . . . . . . .3D

3 ASB-16A . . . . . . . . . . . . . .11A

3 LPC-16 . . . . . . . . . . . . . . . .11A

AC-20 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/3000 . . . . . . . . .3D

3 ASB-16Y . . . . . . . . . . . . . .11A

3 LPC-5 . . . . . . . . . . . . . . . . .11A

AC-22 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/4000 . . . . . . . .3D

3 ASB-1A . . . . . . . . . . . . . . .11A

3 LPC-8 . . . . . . . . . . . . . . . . .11A

AC-24 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/4100 . . . . . . . .3D

3 ASB-1Y . . . . . . . . . . . . . . .11A

3 LPD-15 . . . . . . . . . . . . . . . .11A

AC-26 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/4200 . . . . . . . .3D

3 ASB-5 . . . . . . . . . . . . . . . .11A

3 LPD-16 . . . . . . . . . . . . . . . .11A

AC-28 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/4300 . . . . . . . .3D

3 ASB-5A . . . . . . . . . . . . . . .11A

3 LPD-5 . . . . . . . . . . . . . . . . .11A

AC-30 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/5000 . . . . . . . . .3D

3 ASB-5Y . . . . . . . . . . . . . . .11A

3 LPD-8 . . . . . . . . . . . . . . . . .11A

AC-32 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/6000 . . . . . . . . .3D

3 ASB-8 . . . . . . . . . . . . . . . .11A

3 LPE . . . . . . . . . . . . . . . . . .11A

AC-34 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/6100 . . . . . . . . .3D

3 ASB-8A . . . . . . . . . . . . . . .11A

3000-128

1 GA . . . . .11A

AC-36 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/6200 . . . . . . . . .3D

3 ASB-8Y . . . . . . . . . . . . . . .11A

3000-16

1 PT . . . . . .11A

AC-38 . . . . . . . . . . . . . . . . . .11A

07-3323-1400/6300 . . . . . . . . .3D

3 ASC-1 . . . . . . . . . . . . . . . .11A

3000-32

1 QT . . . . .11A

AC-6 . . . . . . . . . . . . . . . . . . .11A

07-3353-1110/1000 . . . . . . . . .3D

3 ASC-15 . . . . . . . . . . . . . . .11A

3000-640 1-149 GAL. 5 GA .11A

AC-8 . . . . . . . . . . . . . . . . . . .11A

07-3353-1120/2000 . . . . . . . . .3D

3 ASC-15A . . . . . . . . . . . . . .11A

3000-640 150 & OVER 5 GA 11A

ACS-10 . . . . . . . . . . . . . . . . .11A

07-3353-1130/3000 . . . . . . . . .3D

3 ASC-15Y . . . . . . . . . . . . . .11A

3000-8

1/2 . . . . . . .11A

ACS-12 . . . . . . . . . . . . . . . . .11A

07-3353-1140/4000 . . . . . . . . .3D

3 ASC-16 . . . . . . . . . . . . . . .11A

3-S BUSHING . . . . . . . . . . . .11A

ACS-14 . . . . . . . . . . . . . . . . .11A

07-3353-1150/5000 . . . . . . . . .3D

3 ASC-16A . . . . . . . . . . . . . .11A

3SA-15 . . . . . . . . . . . . . . . . .11A

ACS-16 . . . . . . . . . . . . . . . . .11A

08P06 . . . . . . . . . . . . . . . . . . .1C

3 ASC-16Y . . . . . . . . . . . . . .11A

3SA-16 . . . . . . . . . . . . . . . . .11A

ACS-18 . . . . . . . . . . . . . . . . .11A

08P08 . . . . . . . . . . . . . . . . . . .1C

3 ASC-1A . . . . . . . . . . . . . . .11A

3SA-25 . . . . . . . . . . . . . . . . .11A

ACS-20 . . . . . . . . . . . . . . . . .11A

10P08 . . . . . . . . . . . . . . . . . . .1C

3 ASC-1Y . . . . . . . . . . . . . . .11A

3SA-5 . . . . . . . . . . . . . . . . . .11A

ACS-22 . . . . . . . . . . . . . . . . .11A

10P10 . . . . . . . . . . . . . . . . . . .1C

3 ASC-5 . . . . . . . . . . . . . . . .11A

3SA-8 . . . . . . . . . . . . . . . . . .11A

ACS-24 . . . . . . . . . . . . . . . . .11A

359
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 360

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

ACS-26 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-302408 . . . . .1A

C-BUSHING . . . . . . . . . . . . .11A

CGP 4812 . . . . . . . . . . . . . . .11A

ACS-28 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-302412 . . . . .1A

CG 138-15 . . . . . . . . . . . . . . .11A

CGP 4812-M . . . . . . . . . . . . .11A

ACS-30 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-302420 . . . . .1A

CG 155-15 . . . . . . . . . . . . . . .11A

CGP 4875 . . . . . . . . . . . . . . .11A

ACS-32 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-303008 . . . . .1A

CG 174-20 . . . . . . . . . . . . . . .11A

CGP 4875-M . . . . . . . . . . . . .11A

ACS-34 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-303012 . . . . .1A

CG 188-20 . . . . . . . . . . . . . . .11A

CGP 4938 . . . . . . . . . . . . . . .11A

ACS-36 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-362408 . . . . .1A

CG 195-20 . . . . . . . . . . . . . . .11A

CGP 4938-M . . . . . . . . . . . . .11A

ACS-38 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-362412 . . . . .1A

CG 219-25 . . . . . . . . . . . . . . .11A

CGP 51000 . . . . . . . . . . . . . .11A

ACS-40 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-363008 . . . . .1A

CG 236-25 . . . . . . . . . . . . . . .11A

CGP 51000-M . . . . . . . . . . . .11A

ACS-42 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-363012 . . . . .1A

CG 263-30 . . . . . . . . . . . . . . .11A

CGP 51125 . . . . . . . . . . . . . .11A

ACS-44 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-363016 . . . . .1A

CG 280-30 . . . . . . . . . . . . . . .11A

CGP 51125-M . . . . . . . . . . . .11A

ACS-46 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-363020 . . . . .1A

CG 296-30 . . . . . . . . . . . . . . .11A

CGP 51250 . . . . . . . . . . . . . .11A

ACS-48 . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-363608 . . . . .1A

CG 297-35 . . . . . . . . . . . . . . .11A

CGP 51250-M . . . . . . . . . . . .11A

ACS-6 . . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-363612 . . . . .1A

CG 311-35 . . . . . . . . . . . . . . .11A

CGP 51375 . . . . . . . . . . . . . .11A

ACS-8 . . . . . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-423612 . . . . .1A

CG 327-35 . . . . . . . . . . . . . . .11A

CGP 51375-M . . . . . . . . . . . .11A

AIPBCAR . . . . . . . . . . . . . . . .7A

AVSS(or AVSS6)-483612 . . . . .1A

CG 343-35 . . . . . . . . . . . . . . .11A

CGP 5875 . . . . . . . . . . . . . . .11A

AIPBCBE . . . . . . . . . . . . . . . .7A

AVSS(or AVSS6)-483616 . . . . .1A

CG 364-40 . . . . . . . . . . . . . . .11A

CGP 61000 . . . . . . . . . . . . . .11A

AIPBCCR . . . . . . . . . . . . . . . .7A

AVSS(or AVSS6)-603612 . . . . .1A

CG 369-40 . . . . . . . . . . . . . . .11A

CGP 61000-M . . . . . . . . . . . .11A

AIPBCGN . . . . . . . . . . . . . . . .7A

B-1 BLADE . . . . . . . . . . . . . .11A

CG 387-40 . . . . . . . . . . . . . . .11A

CGP 61125 . . . . . . . . . . . . . .11A

AIPBCRD . . . . . . . . . . . . . . . .7A

BAC 12 . . . . . . . . . . . . . . . . .11A

CGP 2188 . . . . . . . . . . . . . . .11A

CGP 61125-M . . . . . . . . . . . .11A

AIPBCWE . . . . . . . . . . . . . . . .7A

BAC 15 . . . . . . . . . . . . . . . . .11A

CGP 2250 . . . . . . . . . . . . . . .11A

CGP 61250 . . . . . . . . . . . . . .11A

APLLAR . . . . . . . . . . . . . . . . .7A

BAC 20 . . . . . . . . . . . . . . . . .11A

CGP 2250-M . . . . . . . . . . . . .11A

CGP 61250-M . . . . . . . . . . . .11A

APLLBE . . . . . . . . . . . . . . . . .7A

BAC 25 . . . . . . . . . . . . . . . . .11A

CGP 2312 . . . . . . . . . . . . . . .11A

CGP 61375 . . . . . . . . . . . . . .11A

APLLCR . . . . . . . . . . . . . . . . .7A

BAC 30 . . . . . . . . . . . . . . . . .11A

CGP 2312-M . . . . . . . . . . . . .11A

CGP 61375-M . . . . . . . . . . . .11A

APLLGN . . . . . . . . . . . . . . . . .7A

BAC 35 . . . . . . . . . . . . . . . . .11A

CGP 2375 . . . . . . . . . . . . . . .11A

CGP 6875 . . . . . . . . . . . . . . .11A

APLLRD . . . . . . . . . . . . . . . . .7A

BAC 40 . . . . . . . . . . . . . . . . .11A

CGP 2375-M . . . . . . . . . . . . .11A

CGP 81250 . . . . . . . . . . . . . .11A

APLLWE . . . . . . . . . . . . . . . . .7A

BAC 50 . . . . . . . . . . . . . . . . .11A

CGP 2438 . . . . . . . . . . . . . . .11A

CGP 81562 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-121206 . . . . .1A

BAC 60 . . . . . . . . . . . . . . . . .11A

CGP 2438-M . . . . . . . . . . . . .11A

CGP 81562-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-161206 . . . . .1A

B-BUSHING . . . . . . . . . . . . .11A

CGP 2500 . . . . . . . . . . . . . . .11A

CGP 81688 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-161208 . . . . .1A

BCV 20 . . . . . . . . . . . . . . . . .11A

CGP 2500-M . . . . . . . . . . . . .11A

CGP 81688-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-161606 . . . . .1A

BCV 25 . . . . . . . . . . . . . . . . .11A

CGP 2562 . . . . . . . . . . . . . . .11A

CGP 81812 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-161608 . . . . .1A

BCV 30 . . . . . . . . . . . . . . . . .11A

CGP 2562-M . . . . . . . . . . . . .11A

CGP 81812-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-162008 . . . . .1A

BCV 35 . . . . . . . . . . . . . . . . .11A

CGP 2625 . . . . . . . . . . . . . . .11A

CGP 92188 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-201606 . . . . .1A

BCV 40 . . . . . . . . . . . . . . . . .11A

CGP 2625-M . . . . . . . . . . . . .11A

CGP 92250 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-201608 . . . . .1A

BCV 50 . . . . . . . . . . . . . . . . .11A

CGP 3562 . . . . . . . . . . . . . . .11A

CGP 92250-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-202006 . . . . .1A

BCV 60 . . . . . . . . . . . . . . . . .11A

CGP 3562-M . . . . . . . . . . . . .11A

CGP 92312 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-202008 . . . . .1A

BT-15 . . . . . . . . . . . . . . . . . .11A

CGP 3625 . . . . . . . . . . . . . . .11A

CGP 92312-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-202012 . . . . .1A

BT1A . . . . . . . . . . . . . . . . . . .9A

CGP 3625-M . . . . . . . . . . . . .11A

CGP 92375 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-202408 . . . . .1A

BT1B . . . . . . . . . . . . . . . . . . .9A

CGP 3688 . . . . . . . . . . . . . . .11A

CGP 92375-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-241606 . . . . .1A

BT2 . . . . . . . . . . . . . . . . . . . . .9A

CGP 3688-M . . . . . . . . . . . . .11A

CGP 92438 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-241608 . . . . .1A

BT-20 . . . . . . . . . . . . . . . . . .11A

CGP 3725 . . . . . . . . . . . . . . .11A

CGP 92438-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-242006 . . . . .1A

BT-25 . . . . . . . . . . . . . . . . . .11A

CGP 3725-M . . . . . . . . . . . . .11A

CGP 92500 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-242008 . . . . .1A

BT3 . . . . . . . . . . . . . . . . . . . . .9A

CGP 3812 . . . . . . . . . . . . . . .11A

CGP 92500-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-242012 . . . . .1A

BT-3 . . . . . . . . . . . . . . . . . . .11A

CGP 4562 . . . . . . . . . . . . . . .11A

CGP 92562 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-242406 . . . . .1A

BT-30 . . . . . . . . . . . . . . . . . .11A

CGP 4562-M . . . . . . . . . . . . .11A

CGP 92562-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-242408 . . . . .1A

BT-35 . . . . . . . . . . . . . . . . . .11A

CGP 4625 . . . . . . . . . . . . . . .11A

CGP 92625 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-242412 . . . . .1A

BT4 . . . . . . . . . . . . . . . . . . . . .9A

CGP 4625-M . . . . . . . . . . . . .11A

CGP 92625-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-242416 . . . . .1A

BT-40 . . . . . . . . . . . . . . . . . .11A

CGP 4688 . . . . . . . . . . . . . . .11A

CGP 93562 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-242420 . . . . .1A

BT44 . . . . . . . . . . . . . . . . . . . .9A

CGP 4688-M . . . . . . . . . . . . .11A

CGP 93562-M . . . . . . . . . . . .11A

AVSS(or AVSS6)-243008 . . . . .1A

BT5 . . . . . . . . . . . . . . . . . . . . .9A

CGP 4750 . . . . . . . . . . . . . . .11A

CGP 93625 . . . . . . . . . . . . . .11A

AVSS(or AVSS6)-302008 . . . . .1A

BT-50 . . . . . . . . . . . . . . . . . .11A

CGP 4750-M . . . . . . . . . . . . .11A

CGP 93625-M . . . . . . . . . . . .11A

360
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 361

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

CGP 93688 . . . . . . . . . . . . . .11A

CN4(X or X6)-2016xx . . . . . . . .3D

CVS-60 1-3/C . . . . . . . . . . . . .11A

FSP 2 . . . . . . . . . . . . . . . . . . .5E

CGP 93688-M . . . . . . . . . . . .11A

CN4(X or X6)-2020xx . . . . . . . .3D

CVS-60 3-1/C . . . . . . . . . . . . .11A

FSP 3 . . . . . . . . . . . . . . . . . . .5E

CGP 93725 . . . . . . . . . . . . . .11A

CN4(X or X6)-2024xx . . . . . . . .3D

D-60P48 . . . . . . . . . . . . . . . . .1A

FVLU . . . . . . . . . . . . . . . . . . .7A

CGP 93725-M . . . . . . . . . . . .11A

CN4(X or X6)-2412xx . . . . . . . .3D

D-60P60 . . . . . . . . . . . . . . . . .1A

FVLU12 . . . . . . . . . . . . . . . . . .7A

CGP 93812 . . . . . . . . . . . . . .11A

CN4(X or X6)-2416xx . . . . . . . .3D

D-72P60 . . . . . . . . . . . . . . . . .1A

FVLU120 . . . . . . . . . . . . . . . . .7A

CGP 93812-M . . . . . . . . . . . .11A

CN4(X or X6)-2420xx . . . . . . . .3D

D-72P72 . . . . . . . . . . . . . . . . .1A

FVLU120FS . . . . . . . . . . . . . . .7A

CGP 94562 . . . . . . . . . . . . . .11A

CN4(X or X6)-2424xx . . . . . . . .3D

D-BUSHING . . . . . . . . . . . . .11A

FVLU120N . . . . . . . . . . . . . . .7A

CGP 94562-M . . . . . . . . . . . .11A

CN4(X or X6)-2430xx . . . . . . . .3D

DIF 101406 . . . . . . . . . . . . . . .5B

FVLU120NFS . . . . . . . . . . . . .7A

CGP 94625 . . . . . . . . . . . . . .11A

CN4(X or X6)-301606 . . . . . . .3D

DIF 164810 . . . . . . . . . . . . . . .5B

FVLU12FS . . . . . . . . . . . . . . . .7A

CGP 94625-M . . . . . . . . . . . .11A

CN4(X or X6)-3020xx . . . . . . . .3D

DIF 202408 . . . . . . . . . . . . . . .5B

FVLU24 . . . . . . . . . . . . . . . . . .7A

CGP 94688 . . . . . . . . . . . . . .11A

CN4(X or X6)-3024xx . . . . . . . .3D

DIF 243608 . . . . . . . . . . . . . . .5B

FVLU24FS . . . . . . . . . . . . . . . .7A

CGP 94688-M . . . . . . . . . . . .11A

CN4(X or X6)-3030xx . . . . . . . .3D

DIF 364808 . . . . . . . . . . . . . . .5B

FVLU6 . . . . . . . . . . . . . . . . . . .7A

CGP 94750 . . . . . . . . . . . . . .11A

CN4(X or X6)-303608 . . . . . . .3D

DJF 061105 . . . . . . . . . . . . . .5A

FVLU6FS . . . . . . . . . . . . . . . .7A

CGP 94750-M . . . . . . . . . . . .11A

CN4(X or X6)-3624xx . . . . . . . .3D

DJF 061305 . . . . . . . . . . . . . .5A

FVLUFS . . . . . . . . . . . . . . . . .7A

CGP 94812 . . . . . . . . . . . . . .11A

CN4(X or X6)-3630xx . . . . . . . .3D

DJF 071805 . . . . . . . . . . . . . .5A

FVPPM120-IMCRD-FS . . . . . .7A

CGP 94812-M . . . . . . . . . . . .11A

CN4(X or X6)-3636xx . . . . . . . .3D

DJF 121806 . . . . . . . . . . . . . .5A

FVPPM120-IMCRD-FS/FS . . . .7A

CGP 94875 . . . . . . . . . . . . . .11A

CN4(X or X6)-422408 . . . . . . .3D

DJF 122005 . . . . . . . . . . . . . .5A

FVPPM120NR-IMCRD-FS . . . .7A

CGP 94875-M . . . . . . . . . . . .11A

CN4(X or X6)-4230xx . . . . . . . .3D

DJF 122406 . . . . . . . . . . . . . .5A

FVPPM120NR-IMCRD-FS/FS .7A

CGP 94938 . . . . . . . . . . . . . .11A

CN4(X or X6)-4236xx . . . . . . . .3D

DJF 122408 . . . . . . . . . . . . . .5A

FVPPM12-IMCRD-FS . . . . . . .7A

CGP 94938-M . . . . . . . . . . . .11A

CN4(X or X6)-482408 . . . . . . .3D

DJF 123006 . . . . . . . . . . . . . .5A

FVPPM12-IMCRD-FS/FS . . . . .7A

CGP 951000 . . . . . . . . . . . . .11A

CN4(X or X6)-4830xx . . . . . . . .3D

DJF 123208 . . . . . . . . . . . . . .5A

FVPPM24-IMCRD-FS . . . . . . .7A

CGP 951000-M . . . . . . . . . . .11A

CN4(X or X6)-4836xx . . . . . . . .3D

DJF 123608 . . . . . . . . . . . . . .5A

FVPPM24-IMCRD-FS/FS . . . . .7A

CGP 951125 . . . . . . . . . . . . .11A

CN4(X or X6)-6036xx . . . . . . . .3D

FDO . . . . . . . . . . . . . . . . . . . .5E

FVPPM6-IMCRD-FS . . . . . . . .7A

CGP 951125-M . . . . . . . . . . .11A

Color adder for legend plates .7A

FL 92 . . . . . . . . . . . . . . . . . .10A

FVPPM6-IMCRD-FS/FS . . . . . .7A

CGP 951250 . . . . . . . . . . . . .11A

CV-20 1-3/C . . . . . . . . . . . . . .11A

FL 93 . . . . . . . . . . . . . . . . . .10A

FVPPT120NFS . . . . . . . . . . . .7A

CGP 951250-M . . . . . . . . . . .11A

CV-20 3-1/C . . . . . . . . . . . . . .11A

FL 94 . . . . . . . . . . . . . . . . . .10A

FVPTT120FS . . . . . . . . . . . . . .7A

CGP 951375 . . . . . . . . . . . . .11A

CV-25 1-3/C . . . . . . . . . . . . . .11A

FL 96 . . . . . . . . . . . . . . . . . .10A

FVPTT12FS . . . . . . . . . . . . . . .7A

CGP 951375-M . . . . . . . . . . .11A

CV-25 3-1/C . . . . . . . . . . . . . .11A

FS 21 . . . . . . . . . . . . . . . . . . .5E

FVPTT24FS . . . . . . . . . . . . . . .7A

CGP 95875 . . . . . . . . . . . . . .11A

CV-30 1-3/C . . . . . . . . . . . . . .11A

FS20 . . . . . . . . . . . . . . . . . . .11A

FVPTT6FS . . . . . . . . . . . . . . . .7A

CGP 961000 . . . . . . . . . . . . .11A

CV-30 3-1/C . . . . . . . . . . . . . .11A

FS25 . . . . . . . . . . . . . . . . . . .11A

FVPTTFS . . . . . . . . . . . . . . . . .7A

CGP 961000-M . . . . . . . . . . .11A

CV-35 1-3/C . . . . . . . . . . . . . .11A

FS30 . . . . . . . . . . . . . . . . . . .11A

GHG 418 8131 R0014 . . . . . . .3D

CGP 961125 . . . . . . . . . . . . .11A

CV-35 3-1/C . . . . . . . . . . . . . .11A

FS35 . . . . . . . . . . . . . . . . . . .11A

GHG 418 8131 R0015 . . . . . . .3D

CGP 961125-M . . . . . . . . . . .11A

CV-40 1-3/C . . . . . . . . . . . . . .11A

FS40 . . . . . . . . . . . . . . . . . . .11A

GHG 418 8131 R0016 . . . . . . .3D

CGP 961250 . . . . . . . . . . . . .11A

CV-40 3-1/C . . . . . . . . . . . . . .11A

FS-50 . . . . . . . . . . . . . . . . . .11A

GT-100F 5-50-8 . . . . . . . . . . .11A

CGP 961250-M . . . . . . . . . . .11A

CV-50 1-3/C . . . . . . . . . . . . . .11A

FS525 . . . . . . . . . . . . . . . . . .11A

HV4X6-161606 . . . . . . . . . . . .3C

CGP 961375 . . . . . . . . . . . . .11A

CV-50 3-1/C . . . . . . . . . . . . . .11A

FS535 . . . . . . . . . . . . . . . . . .11A

HV4X6-201206 . . . . . . . . . . . .3C

CGP 961375-M . . . . . . . . . . .11A

CV-60 1-3/C . . . . . . . . . . . . . .11A

FS540 . . . . . . . . . . . . . . . . . .11A

HV4X6-201407 . . . . . . . . . . . .3C

CGP 96875 . . . . . . . . . . . . . .11A

CV-60 3-1/C . . . . . . . . . . . . . .11A

FSBT . . . . . . . . . . . . . . . . . . . .7A

HV4X6-201610 . . . . . . . . . . . .3C

CGP 981250 . . . . . . . . . . . . .11A

CVS-20 1-3/C . . . . . . . . . . . . .11A

FSD . . . . . . . . . . . . . . . . . . .11A

HV4X6-202006 . . . . . . . . . . . .3C

CGP 981562 . . . . . . . . . . . . .11A

CVS-20 3-1/C . . . . . . . . . . . . .11A

FSD-35 . . . . . . . . . . . . . . . . .11A

HV4X6-202008 . . . . . . . . . . . .3C

CGP 981562-M . . . . . . . . . . .11A

CVS-25 1-3/C . . . . . . . . . . . . .11A

FSDG-31 . . . . . . . . . . . . . . . .11A

HV4X6-202010 . . . . . . . . . . . .3C

CGP 981688 . . . . . . . . . . . . .11A

CVS-25 3-1/C . . . . . . . . . . . . .11A

FSDG-32 . . . . . . . . . . . . . . . .11A

HV4X6-241206 . . . . . . . . . . . .3C

CGP 981688-M . . . . . . . . . . .11A

CVS-30 1-3/C . . . . . . . . . . . . .11A

FSDP-3 . . . . . . . . . . . . . . . . .11A

HV4X6-241606 . . . . . . . . . . . .3C

CGP 981812 . . . . . . . . . . . . .11A

CVS-30 3-1/C . . . . . . . . . . . . .11A

FSDP-35 . . . . . . . . . . . . . . . .11A

HV4X6-242006 . . . . . . . . . . . .3C

CGP 981812-M . . . . . . . . . . .11A

CVS-35 1-3/C . . . . . . . . . . . . .11A

FSDS-1 . . . . . . . . . . . . . . . . .11A

HV4X6-242008 . . . . . . . . . . . .3C

CN4(X or X6)-1224xx . . . . . . . .3D

CVS-35 3-1/C . . . . . . . . . . . . .11A

FSDS-2 . . . . . . . . . . . . . . . . .11A

HV4X6-242010 . . . . . . . . . . . .3C

CN4(X or X6)-1612xx . . . . . . . .3D

CVS-40 1-3/C . . . . . . . . . . . . .11A

FSDS-35 . . . . . . . . . . . . . . . .11A

HV4X6-242010 . . . . . . . . . . . .3C

CN4(X or X6)-1616xx . . . . . . . .3D

CVS-40 3-1/C . . . . . . . . . . . . .11A

FSH 2 . . . . . . . . . . . . . . . . . . .5E

HV4X6-242408 . . . . . . . . . . . .3C

CN4(X or X6)-1620xx . . . . . . . .3D

CVS-50 1-3/C . . . . . . . . . . . . .11A

FSH 3 . . . . . . . . . . . . . . . . . . .5E

HV4X6-242410 . . . . . . . . . . . .3C

CN4(X or X6)-2012xx . . . . . . . .3D

CVS-50 3-1/C . . . . . . . . . . . . .11A

FSO . . . . . . . . . . . . . . . . . . . .5E

HV4X6-242410 . . . . . . . . . . . .3C

361
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 362

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

HV4X6-251807 . . . . . . . . . . . .3C

JAG 423-40 . . . . . . . . . . . . . .11A

JH 121810 . . . . . . . . . . . . . . .5D

JN4XSS-101006 . . . . . . . . . . .1A

HV4X6-301606 . . . . . . . . . . . .3C

JAG 437-40 . . . . . . . . . . . . . .11A

JH 122406 . . . . . . . . . . . . . . .5D

JN4XSS-121005 . . . . . . . . . . .1A

HV4X6-302010 . . . . . . . . . . . .3C

JAG 45-05 . . . . . . . . . . . . . . .11A

JH 122408 . . . . . . . . . . . . . . .5D

JN4XSS-121008 . . . . . . . . . . .1A

HV4X6-302010 . . . . . . . . . . . .3C

JAG 451-40 . . . . . . . . . . . . . .11A

JH 123606 . . . . . . . . . . . . . . .5D

JN4XSS-121206 . . . . . . . . . . .1A

HV4X6-302207 . . . . . . . . . . . .3C

JAG 462-40 . . . . . . . . . . . . . .11A

JH 141406 . . . . . . . . . . . . . . .5D

JN4XSS-140806 . . . . . . . . . . .1A

HV4X6-302410 . . . . . . . . . . . .3C

JAG 55-05 . . . . . . . . . . . . . . .11A

JH 151508 . . . . . . . . . . . . . . .5D

JN4XSS-141206 . . . . . . . . . . .1A

HV4X6-302410 . . . . . . . . . . . .3C

JAG 65-05 . . . . . . . . . . . . . . .11A

JH 181806 . . . . . . . . . . . . . . .5D

JN4XSS-141208 . . . . . . . . . . .1A

HV4X6-362410 . . . . . . . . . . . .3C

JAG 75-05 . . . . . . . . . . . . . . .11A

JH 181808 . . . . . . . . . . . . . . .5D

JN4XSS-161406 . . . . . . . . . . .1A

HV4X6-362410 . . . . . . . . . . . .3C

JAG 85-05 . . . . . . . . . . . . . . .11A

JH 181810 . . . . . . . . . . . . . . .5D

JN4XSS-161408 . . . . . . . . . . .1A

HV4X6-362507 . . . . . . . . . . . .3C

JAG 95-05 . . . . . . . . . . . . . . .11A

JH 181812 . . . . . . . . . . . . . . .5D

JN4XSS-161410 . . . . . . . . . . .1A

HV4X6-362510 . . . . . . . . . . . .3C

JAG 99-07 . . . . . . . . . . . . . . .11A

JH 182408 . . . . . . . . . . . . . . .5D

JP 020401 . . . . . . . . . . . . . . .5D

HV4X6-362510 . . . . . . . . . . . .3C

JF 060604 . . . . . . . . . . . . . . .5D

JH 183606 . . . . . . . . . . . . . . .5D

JP 030302 . . . . . . . . . . . . . . .5D

HV4X6-603610 . . . . . . . . . . . .3C

JF 060606 . . . . . . . . . . . . . . .5D

JH 183608 . . . . . . . . . . . . . . .5D

JP 030303 . . . . . . . . . . . . . . .5D

HV4X6-603610 . . . . . . . . . . . .3C

JF 060804 . . . . . . . . . . . . . . .5D

JH 242408 . . . . . . . . . . . . . . .5D

JP 040403 . . . . . . . . . . . . . . .5D

HV4X6-603616 . . . . . . . . . . . .3C

JF 060806 . . . . . . . . . . . . . . .5D

JH 243008 . . . . . . . . . . . . . . .5D

JP 040404 . . . . . . . . . . . . . . .5D

IPBCAR . . . . . . . . . . . . . . . . . .7A

JF 061206 . . . . . . . . . . . . . . .5D

JH 243606 . . . . . . . . . . . . . . .5D

JP 040603 . . . . . . . . . . . . . . .5D

IPBCBE . . . . . . . . . . . . . . . . . .7A

JF 080804 . . . . . . . . . . . . . . .5D

JH 243608 . . . . . . . . . . . . . . .5D

JP 040604 . . . . . . . . . . . . . . .5D

IPBCCR . . . . . . . . . . . . . . . . . .7A

JF 080806 . . . . . . . . . . . . . . .5D

JH 243612 . . . . . . . . . . . . . . .5D

JP 040804 . . . . . . . . . . . . . . .5D

IPBCGN . . . . . . . . . . . . . . . . .7A

JF 081206 . . . . . . . . . . . . . . .5D

JN4XHA-060604 . . . . . . . . . . .1B

JP 041204 . . . . . . . . . . . . . . .5D

IPBCRD . . . . . . . . . . . . . . . . .7A

JF 121206 . . . . . . . . . . . . . . .5D

JN4XHA-080604 . . . . . . . . . . .1B

JP 060603 . . . . . . . . . . . . . . .5D

IPBCWE . . . . . . . . . . . . . . . . .7A

JF 121208 . . . . . . . . . . . . . . .5D

JN4XHA-100804 . . . . . . . . . . .1B

JP 060604 . . . . . . . . . . . . . . .5D

JAG 107-07 . . . . . . . . . . . . . .11A

JF 121810 . . . . . . . . . . . . . . .5D

JN4XHA-121005 . . . . . . . . . . .1B

JP 060606 . . . . . . . . . . . . . . .5D

JAG 112-10 . . . . . . . . . . . . . .11A

JF 122406 . . . . . . . . . . . . . . .5D

JN4XHA-141206 . . . . . . . . . . .1B

JP 060804 . . . . . . . . . . . . . . .5D

JAG 113-07 . . . . . . . . . . . . . .11A

JF 122408 . . . . . . . . . . . . . . .5D

JN4XHA-161406 . . . . . . . . . . .1B

JP 060806 . . . . . . . . . . . . . . .5D

JAG 121-07 . . . . . . . . . . . . . .11A

JF 183608 . . . . . . . . . . . . . . .5D

JN4XHSS-060403 . . . . . . . . . .1A

JP 061004 . . . . . . . . . . . . . . .5D

JAG 125-10 . . . . . . . . . . . . . .11A

JH 060604 . . . . . . . . . . . . . . .5D

JN4XHSS-060404 . . . . . . . . . .1A

JP 061204 . . . . . . . . . . . . . . .5D

JAG 138-10 . . . . . . . . . . . . . .11A

JH 060606 . . . . . . . . . . . . . . .5D

JN4XHSS-060604 . . . . . . . . . .1A

JP 061206 . . . . . . . . . . . . . . .5D

JAG 138-12 . . . . . . . . . . . . . .11A

JH 060804 . . . . . . . . . . . . . . .5D

JN4XHSS-080604 . . . . . . . . . .1A

JP 080804 . . . . . . . . . . . . . . .5D

JAG 156-12 . . . . . . . . . . . . . .11A

JH 060806 . . . . . . . . . . . . . . .5D

JN4XHSS-080606 . . . . . . . . . .1A

JP 080806 . . . . . . . . . . . . . . .5D

JAG 174-12 . . . . . . . . . . . . . .11A

JH 061004 . . . . . . . . . . . . . . .5D

JN4XHSS-080804 . . . . . . . . . .1A

JP 080808 . . . . . . . . . . . . . . .5D

JAG 174-15 . . . . . . . . . . . . . .11A

JH 061204 . . . . . . . . . . . . . . .5D

JN4XHSS-100804 . . . . . . . . . .1A

JP 081004 . . . . . . . . . . . . . . .5D

JAG 188-12 . . . . . . . . . . . . . .11A

JH 061206 . . . . . . . . . . . . . . .5D

JN4XHSS-100806 . . . . . . . . . .1A

JP 081006 . . . . . . . . . . . . . . .5D

JAG 188-15 . . . . . . . . . . . . . .11A

JH 080804 . . . . . . . . . . . . . . .5D

JN4XHSS-101006 . . . . . . . . . .1A

JP 081008 . . . . . . . . . . . . . . .5D

JAG 200-15 . . . . . . . . . . . . . .11A

JH 080806 . . . . . . . . . . . . . . .5D

JN4XHSS-121005 . . . . . . . . . .1A

JP 081204 . . . . . . . . . . . . . . .5D

JAG 218-15 . . . . . . . . . . . . . .11A

JH 080808 . . . . . . . . . . . . . . .5D

JN4XHSS-121008 . . . . . . . . . .1A

JP 081206 . . . . . . . . . . . . . . .5D

JAG 219-20 . . . . . . . . . . . . . .11A

JH 081004 . . . . . . . . . . . . . . .5D

JN4XHSS-121206 . . . . . . . . . .1A

JP 101204 . . . . . . . . . . . . . . .5D

JAG 236-20 . . . . . . . . . . . . . .11A

JH 081006 . . . . . . . . . . . . . . .5D

JN4XHSS-140806 . . . . . . . . . .1A

JP 101206 . . . . . . . . . . . . . . .5D

JAG 247-20 . . . . . . . . . . . . . .11A

JH 081008 . . . . . . . . . . . . . . .5D

JN4XHSS-141206 . . . . . . . . . .1A

JP 101208 . . . . . . . . . . . . . . .5D

JAG 261-20 . . . . . . . . . . . . . .11A

JH 081204 . . . . . . . . . . . . . . .5D

JN4XHSS-141208 . . . . . . . . . .1A

JP 121204 . . . . . . . . . . . . . . .5D

JAG 263-25 . . . . . . . . . . . . . .11A

JH 081206 . . . . . . . . . . . . . . .5D

JN4XHSS-161406 . . . . . . . . . .1A

JP 121206 . . . . . . . . . . . . . . .5D

JAG 280-25 . . . . . . . . . . . . . .11A

JH 101204 . . . . . . . . . . . . . . .5D

JN4XHSS-161408 . . . . . . . . . .1A

JP 121208 . . . . . . . . . . . . . . .5D

JAG 296-25 . . . . . . . . . . . . . .11A

JH 101206 . . . . . . . . . . . . . . .5D

JN4XHSS-161410 . . . . . . . . . .1A

JP 121604 . . . . . . . . . . . . . . .5D

JAG 297-30 . . . . . . . . . . . . . .11A

JH 101208 . . . . . . . . . . . . . . .5D

JN4XSS-060403 . . . . . . . . . . .1A

JP 121606 . . . . . . . . . . . . . . .5D

JAG 311-30 . . . . . . . . . . . . . .11A

JH 121204 . . . . . . . . . . . . . . .5D

JN4XSS-060404 . . . . . . . . . . .1A

JP 121608 . . . . . . . . . . . . . . .5D

JAG 327-30 . . . . . . . . . . . . . .11A

JH 121206 . . . . . . . . . . . . . . .5D

JN4XSS-060604 . . . . . . . . . . .1A

JP 121806 . . . . . . . . . . . . . . .5D

JAG 343-30 . . . . . . . . . . . . . .11A

JH 121208 . . . . . . . . . . . . . . .5D

JN4XSS-080604 . . . . . . . . . . .1A

JP 121810 . . . . . . . . . . . . . . .5D

JAG 359-30 . . . . . . . . . . . . . .11A

JH 121604 . . . . . . . . . . . . . . .5D

JN4XSS-080606 . . . . . . . . . . .1A

JP 122406 . . . . . . . . . . . . . . .5D

JAG 375-35 . . . . . . . . . . . . . .11A

JH 121606 . . . . . . . . . . . . . . .5D

JN4XSS-080804 . . . . . . . . . . .1A

JP 122408 . . . . . . . . . . . . . . .5D

JAG 392-35 . . . . . . . . . . . . . .11A

JH 121608 . . . . . . . . . . . . . . .5D

JN4XSS-100804 . . . . . . . . . . .1A

JP 123606 . . . . . . . . . . . . . . .5D

JAG 412-35 . . . . . . . . . . . . . .11A

JH 121806 . . . . . . . . . . . . . . .5D

JN4XSS-100806 . . . . . . . . . . .1A

JP 141406 . . . . . . . . . . . . . . .5D

362
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 363

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

JP 151508 . . . . . . . . . . . . . . .5D

KOSRLRC-KL-FS . . . . . . . . . . .7A

KOSS3-KLR-FS/FS . . . . . . . . . .7A

N4X(or N4X6)-302408 . . . . . . .1A

JP 181806 . . . . . . . . . . . . . . .5D

KOSRLRC-KL-FS/FS . . . . . . . .7A

KOSS3-KRC-FS . . . . . . . . . . . .7A

N4X(or N4X6)-302410 . . . . . . .1A

JP 181808 . . . . . . . . . . . . . . .5D

KOSRLRC-KL-FS/FS . . . . . . . .7A

KOSS3-KRC-FS/FS . . . . . . . . .7A

N4X(or N4X6)-302412 . . . . . . .1A

JP 181810 . . . . . . . . . . . . . . .5D

KOSRLRC-KLR-FS . . . . . . . . . .7A

KOSS3-KR-FS . . . . . . . . . . . . .7A

N4X(or N4X6)-302416 . . . . . . .1A

JP 181812 . . . . . . . . . . . . . . .5D

KOSRLRC-KLR-FS . . . . . . . . . .7A

KOSS3-KR-FS/FS . . . . . . . . . . .7A

N4X(or N4X6)-302420 . . . . . . .1A

JP 182408 . . . . . . . . . . . . . . .5D

KOSRLRC-KLR-FS/FS . . . . . . .7A

KOSS4-FS . . . . . . . . . . . . . . . .7A

N4X(or N4X6)-302424 . . . . . . .1A

JP 183606 . . . . . . . . . . . . . . .5D

KOSRLRC-KLR-FS/FS . . . . . . .7A

KOSS4-FS/FS . . . . . . . . . . . . .7A

N4X(or N4X6)-303008 . . . . . . .1A

JP 183608 . . . . . . . . . . . . . . .5D

KOSRLRC-KRC-FS . . . . . . . . .7A

LP, LPN, LPS . . . . . . . . . . . . . .7A

N4X(or N4X6)-303012 . . . . . . .1A

JP 242408 . . . . . . . . . . . . . . .5D

KOSRLRC-KRC-FS . . . . . . . . .7A

LPB . . . . . . . . . . . . . . . . . . . .11A

N4X(or N4X6)-362406 . . . . . . .1A

JP 242410 . . . . . . . . . . . . . . .5D

KOSRLRC-KRC-FS/FS . . . . . . .7A

LPC . . . . . . . . . . . . . . . . . . . .11A

N4X(or N4X6)-362408 . . . . . . .1A

JP 243008 . . . . . . . . . . . . . . .5D

KOSRLRC-KRC-FS/FS . . . . . . .7A

LPD . . . . . . . . . . . . . . . . . . .11A

N4X(or N4X6)-362410 . . . . . . .1A

JP 243606 . . . . . . . . . . . . . . .5D

KOSRLRC-KR-FS . . . . . . . . . . .7A

LPE . . . . . . . . . . . . . . . . . . . .11A

N4X(or N4X6)-362412 . . . . . . .1A

JP 243608 . . . . . . . . . . . . . . .5D

KOSRLRC-KR-FS . . . . . . . . . . .7A

M1423 . . . . . . . . . . . . . . . . . .1C

N4X(or N4X6)-363006 . . . . . . .1A

JP 243612 . . . . . . . . . . . . . . .5D

KOSRLRC-KR-FS/FS . . . . . . . .7A

MFL 92 . . . . . . . . . . . . . . . . .10A

N4X(or N4X6)-363008 . . . . . . .1A

JP 363612 . . . . . . . . . . . . . . .5D

KOSRLRC-KR-FS/FS . . . . . . . .7A

MFL 93 . . . . . . . . . . . . . . . . .10A

N4X(or N4X6)-363010 . . . . . . .1A

JR 040404 . . . . . . . . . . . . . . .5D

KOSRRC-FS . . . . . . . . . . . . . .7A

MFL 94 . . . . . . . . . . . . . . . . .10A

N4X(or N4X6)-363012 . . . . . . .1A

JR 040604 . . . . . . . . . . . . . . .5D

KOSRRC-FS/FS . . . . . . . . . . . .7A

MFL 95 . . . . . . . . . . . . . . . . .10A

N4X(or N4X6)-363016 . . . . . . .1A

JR 060604 . . . . . . . . . . . . . . .5D

KOSRRC-KC-FS . . . . . . . . . . . .7A

MFL 96 . . . . . . . . . . . . . . . . .10A

N4X(or N4X6)-363020 . . . . . . .1A

JR 060606 . . . . . . . . . . . . . . .5D

KOSRRC-KC-FS/FS . . . . . . . . .7A

N4X(or N4X6)-161206 . . . . . . .1A

N4X(or N4X6)-363608 . . . . . . .1A

JR 060804 . . . . . . . . . . . . . . .5D

KOSRRC-KLC-FS . . . . . . . . . . .7A

N4X(or N4X6)-161208 . . . . . . .1A

N4X(or N4X6)-363612 . . . . . . .1A

JR 060806 . . . . . . . . . . . . . . .5D

KOSRRC-KLC-FS/FS . . . . . . . .7A

N4X(or N4X6)-161606 . . . . . . .1A

N4X(or N4X6)-423008 . . . . . . .1A

JR 061006 . . . . . . . . . . . . . . .5D

KOSRRC-KL-FS . . . . . . . . . . . .7A

N4X(or N4X6)-161608 . . . . . . .1A

N4X(or N4X6)-423010 . . . . . . .1A

JR 061206 . . . . . . . . . . . . . . .5D

KOSRRC-KL-FS/FS . . . . . . . . .7A

N4X(or N4X6)-162006 . . . . . . .1A

N4X(or N4X6)-423012 . . . . . . .1A

JR 080804 . . . . . . . . . . . . . . .5D

KOSRRC-KLR-FS . . . . . . . . . . .7A

N4X(or N4X6)-162008 . . . . . . .1A

N4X(or N4X6)-423608 . . . . . . .1A

JR 080806 . . . . . . . . . . . . . . .5D

KOSRRC-KLR-FS/FS . . . . . . . .7A

N4X(or N4X6)-201606 . . . . . . .1A

N4X(or N4X6)-423610 . . . . . . .1A

JR 080808 . . . . . . . . . . . . . . .5D

KOSRRC-KRC-FS . . . . . . . . . .7A

N4X(or N4X6)-201608 . . . . . . .1A

N4X(or N4X6)-423612 . . . . . . .1A

JR 081206 . . . . . . . . . . . . . . .5D

KOSRRC-KRC-FS/FS . . . . . . . .7A

N4X(or N4X6)-201610 . . . . . . .1A

N4X(or N4X6)-423616 . . . . . . .1A

JR 101006 . . . . . . . . . . . . . . .5D

KOSRRC-KR-FS . . . . . . . . . . . .7A

N4X(or N4X6)-201612 . . . . . . .1A

N4X(or N4X6)-483608 . . . . . . .1A

JR 121206 . . . . . . . . . . . . . . .5D

KOSRRC-KR-FS/FS . . . . . . . . .7A

N4X(or N4X6)-202006 . . . . . . .1A

N4X(or N4X6)-483610 . . . . . . .1A

JR 121208 . . . . . . . . . . . . . . .5D

KOSRRL-FS . . . . . . . . . . . . . .7A

N4X(or N4X6)-202008 . . . . . . .1A

N4X(or N4X6)-483612 . . . . . . .1A

JR 121810 . . . . . . . . . . . . . . .5D

KOSRRL-FS/FS . . . . . . . . . . . .7A

N4X(or N4X6)-202010 . . . . . . .1A

N4X(or N4X6)-483616 . . . . . . .1A

JR 122406 . . . . . . . . . . . . . . .5D

KOSRRL-FS/FS-KL . . . . . . . . .7A

N4X(or N4X6)-202406 . . . . . . .1A

N4X(or N4X6)-483620 . . . . . . .1A

JR 161606 . . . . . . . . . . . . . . .5D

KOSRRL-FS-KL . . . . . . . . . . . .7A

N4X(or N4X6)-202408 . . . . . . .1A

N4X(or N4X6)-603610 . . . . . . .1A

JR 161808 . . . . . . . . . . . . . . .5D

KOSS2-FS . . . . . . . . . . . . . . . .7A

N4X(or N4X6)-241206 . . . . . . .1A

N4X(or N4X6)-603612 . . . . . . .1A

JR 161810 . . . . . . . . . . . . . . .5D

KOSS2-FS/FS . . . . . . . . . . . . .7A

N4X(or N4X6)-241606 . . . . . . .1A

N4X(or N4X6)-603616 . . . . . . .1A

JR 181812 . . . . . . . . . . . . . . .5D

KOSS2-KL-FS . . . . . . . . . . . . .7A

N4X(or N4X6)-241608 . . . . . . .1A

N4X(or N4X6)-603620 . . . . . . .1A

JR 183608 . . . . . . . . . . . . . . .5D

KOSS2-KL-FS/FS . . . . . . . . . . .7A

N4X(or N4X6)-242006 . . . . . . .1A

N4XA-161206 . . . . . . . . . . . . .1B

KOSRLC-FS . . . . . . . . . . . . . .7A

KOSS2-KLR-FS . . . . . . . . . . . .7A

N4X(or N4X6)-242008 . . . . . . .1A

N4XA-161608 . . . . . . . . . . . . .1B

KOSRLC-FS/FS . . . . . . . . . . . .7A

KOSS2-KLR-FS/FS . . . . . . . . . .7A

N4X(or N4X6)-242010 . . . . . . .1A

N4XA-201606 . . . . . . . . . . . . .1B

KOSRLRC-FS . . . . . . . . . . . . .7A

KOSS2-KR-FS . . . . . . . . . . . . .7A

N4X(or N4X6)-242012 . . . . . . .1A

N4XA-201610 . . . . . . . . . . . . .1B

KOSRLRC-FS/FS . . . . . . . . . . .7A

KOSS2-KR-FS/FS . . . . . . . . . . .7A

N4X(or N4X6)-242016 . . . . . . .1A

N4XA-202006 . . . . . . . . . . . . .1B

KOSRLRC-KC-FS . . . . . . . . . . .7A

KOSS3-FS . . . . . . . . . . . . . . . .7A

N4X(or N4X6)-242406 . . . . . . .1A

N4XA-242006 . . . . . . . . . . . . .1B

KOSRLRC-KC-FS . . . . . . . . . . .7A

KOSS3-FS/FS . . . . . . . . . . . . .7A

N4X(or N4X6)-242408 . . . . . . .1A

N4XA-242010 . . . . . . . . . . . . .1B

KOSRLRC-KC-FS/FS . . . . . . . .7A

KOSS3-KC-FS . . . . . . . . . . . . .7A

N4X(or N4X6)-242410 . . . . . . .1A

N4XA-242408 . . . . . . . . . . . . .1B

KOSRLRC-KC-FS/FS . . . . . . . .7A

KOSS3-KC-FS/FS . . . . . . . . . . .7A

N4X(or N4X6)-242412 . . . . . . .1A

N4XA-302408 . . . . . . . . . . . . .1B

KOSRLRC-KLC-FS . . . . . . . . . .7A

KOSS3-KLC-FS . . . . . . . . . . . .7A

N4X(or N4X6)-242416 . . . . . . .1A

N4XA-302412 . . . . . . . . . . . . .1B

KOSRLRC-KLC-FS . . . . . . . . . .7A

KOSS3-KLC-FS/FS . . . . . . . . . .7A

N4X(or N4X6)-243008 . . . . . . .1A

N4XA-362408 . . . . . . . . . . . . .1B

KOSRLRC-KLC-FS/FS . . . . . . .7A

KOSS3-KL-FS . . . . . . . . . . . . .7A

N4X(or N4X6)-302006 . . . . . . .1A

N4XA-363008 . . . . . . . . . . . . .1B

KOSRLRC-KLC-FS/FS . . . . . . .7A

KOSS3-KL-FS/FS . . . . . . . . . . .7A

N4X(or N4X6)-302008 . . . . . . .1A

N4XA-363012 . . . . . . . . . . . . .1B

KOSRLRC-KL-FS . . . . . . . . . . .7A

KOSS3-KLR-FS . . . . . . . . . . . .7A

N4X(or N4X6)-302406 . . . . . . .1A

N4XA-483608 . . . . . . . . . . . . .1B

363
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 364

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

N4X-DD-SS-604812 . . . . . . . . .1A

N4X-FG-201608CH . . . . . . . . .2A

PBO-MCGN-FS . . . . . . . . . . . .7A

PEML 6 . . . . . . . . . . . . . . . . .10A

N4X-DD-SS-606012 . . . . . . . . .1A

N4X-FG-201608CHQR . . . . . . .2A

PBO-MCGN-FS/FS . . . . . . . . .7A

PEML 8 . . . . . . . . . . . . . . . . .10A

N4X-DD-SS-726012 . . . . . . . . .1A

N4X-FG-201608CHTL . . . . . . .2A

PBO-MCRD-FS . . . . . . . . . . . .7A

PES 10 . . . . . . . . . . . . . . . . .10A

N4X-DD-SS-727212 . . . . . . . . .1A

N4X-FG-201610RCHQR . . . . .2A

PBO-MCRD-FS/FS . . . . . . . . .7A

PES 12 . . . . . . . . . . . . . . . . .10A

N4X-FG-030302 . . . . . . . . . . . .2A

N4X-FG-201612CH . . . . . . . . .2A

PBO-PPMCBK-FS . . . . . . . . . .7A

PES 14 . . . . . . . . . . . . . . . . .10A

N4X-FG-050302 . . . . . . . . . . . .2A

N4X-FG-242008CH . . . . . . . . .2A

PBO-PPMCBK-FS/FS . . . . . . . .7A

PES 16 . . . . . . . . . . . . . . . . .10A

N4X-FG-060404 . . . . . . . . . . . .2A

N4X-FG-242410CH . . . . . . . . .2A

PBO-PPMCGN-FS . . . . . . . . . .7A

PES 2 . . . . . . . . . . . . . . . . . .10A

N4X-FG-060604CHQR . . . . . . .2A

N4X-FG-2PB . . . . . . . . . . . . . .2A

PBO-PPMCGN-FS/FS . . . . . . .7A

PES 3 . . . . . . . . . . . . . . . . . .10A

N4X-FG-060604CHSC . . . . . . .2A

N4X-FG-302410CH . . . . . . . . .2A

PBO-PPMCRD-FS . . . . . . . . . .7A

PES 4 . . . . . . . . . . . . . . . . . .10A

N4X-FG-060604CHTL . . . . . . .2A

N4X-FG-302412CH . . . . . . . . .2A

PBO-PPMCRD-FS/FS . . . . . . .7A

PES 5 . . . . . . . . . . . . . . . . . .10A

N4X-FG-060604SC . . . . . . . . .2A

N4X-FG-363010CH . . . . . . . . .2A

PBO-PPMCYW-FS . . . . . . . . .7A

PES 6 . . . . . . . . . . . . . . . . . .10A

N4X-FG-070603 . . . . . . . . . . . .2A

N4X-FG-363012CH . . . . . . . . .2A

PBO-PPMCYW-FS/FS . . . . . . .7A

PES 8 . . . . . . . . . . . . . . . . . .10A

N4X-FG-080404 . . . . . . . . . . . .2A

N4X-FG-3PB . . . . . . . . . . . . . .2A

PBO-XCBK-FS . . . . . . . . . . . . .7A

PET 10 . . . . . . . . . . . . . . . . .10A

N4X-FG-080604CHQR . . . . . . .2A

N4X-FG-483616CH . . . . . . . . .2A

PBO-XCBK-FS/FS . . . . . . . . . .7A

PET 12 . . . . . . . . . . . . . . . . .10A

N4X-FG-080604CHSC . . . . . . .2A

OX 10 . . . . . . . . . . . . . . . . . .10A

PBO-XCGN-FS . . . . . . . . . . . .7A

PET 14 . . . . . . . . . . . . . . . . .10A

N4X-FG-080604CHTL . . . . . . .2A

OX 12 . . . . . . . . . . . . . . . . . .10A

PBO-XCGN-FS/FS . . . . . . . . . .7A

PET 16 . . . . . . . . . . . . . . . . .10A

N4X-FG-080604SC . . . . . . . . .2A

OX 14 . . . . . . . . . . . . . . . . . .10A

PBO-XCRD-FS . . . . . . . . . . . . .7A

PET 2 . . . . . . . . . . . . . . . . . .10A

N4X-FG-080606RCHQR . . . . .2A

OX 16 . . . . . . . . . . . . . . . . . .10A

PBO-XCRD-FS/FS . . . . . . . . . .7A

PET 3 . . . . . . . . . . . . . . . . . .10A

N4X-FG-090603 . . . . . . . . . . . .2A

OX 2 . . . . . . . . . . . . . . . . . . .10A

PCK-100 . . . . . . . . . . . . . . . .11A

PET 4 . . . . . . . . . . . . . . . . . .10A

N4X-FG-100804CHQR . . . . . . .2A

OX 3 . . . . . . . . . . . . . . . . . . .10A

PCL-128 . . . . . . . . . . . . . . . .11A

PET 5 . . . . . . . . . . . . . . . . . .10A

N4X-FG-100804CHSC . . . . . . .2A

OX 4 . . . . . . . . . . . . . . . . . . .10A

PCL-2 . . . . . . . . . . . . . . . . . .11A

PET 6 . . . . . . . . . . . . . . . . . .10A

N4X-FG-100804CHTL . . . . . . .2A

OX 5 . . . . . . . . . . . . . . . . . . .10A

PCL-32 . . . . . . . . . . . . . . . . .11A

PET 8 . . . . . . . . . . . . . . . . . .10A

N4X-FG-100804SC . . . . . . . . .2A

OX 6 . . . . . . . . . . . . . . . . . . .10A

PE 10 . . . . . . . . . . . . . . . . . .10A

PLCK-35 . . . . . . . . . . . . . . . .11A

N4X-FG-100806RCHQR . . . . .2A

OX 8 . . . . . . . . . . . . . . . . . . .10A

PE 12 . . . . . . . . . . . . . . . . . .10A

PLLAR . . . . . . . . . . . . . . . . . .7A

N4X-FG-100806RCHTL . . . . . .2A

PBO-AFCBK-FS . . . . . . . . . . . .7A

PE 14 . . . . . . . . . . . . . . . . . .10A

PLLBE . . . . . . . . . . . . . . . . . . .7A

N4X-FG-110404 . . . . . . . . . . . .2A

PBO-AFCBK-FS/FS . . . . . . . . .7A

PE 16 . . . . . . . . . . . . . . . . . .10A

PLLCR . . . . . . . . . . . . . . . . . .7A

N4X-FG-121005CHQR . . . . . . .2A

PBO-AFCGN-FS . . . . . . . . . . .7A

PE 2 . . . . . . . . . . . . . . . . . . .10A

PLLGN . . . . . . . . . . . . . . . . . .7A

N4X-FG-121005CHSC . . . . . . .2A

PBO-AFCGN-FS/FS . . . . . . . . .7A

PE 3 . . . . . . . . . . . . . . . . . . .10A

PLLRD . . . . . . . . . . . . . . . . . .7A

N4X-FG-121005CHTL . . . . . . .2A

PBO-AFCRD-FS . . . . . . . . . . .7A

PE 4 . . . . . . . . . . . . . . . . . . .10A

PLLWE . . . . . . . . . . . . . . . . . .7A

N4X-FG-121005SC . . . . . . . . .2A

PBO-AFCRD-FS/FS . . . . . . . . .7A

PE 5 . . . . . . . . . . . . . . . . . . .10A

PLM Clean . . . . . . . . . . . . . .11A

N4X-FG-121006RCHQR . . . . .2A

PBO-AMCBK-FS . . . . . . . . . . .7A

PE 6 . . . . . . . . . . . . . . . . . . .10A

PM 10 . . . . . . . . . . . . . . . . . .10A

N4X-FG-121006RCHTL . . . . . .2A

PBO-AMCBK-FS/FS . . . . . . . . .7A

PE 8 . . . . . . . . . . . . . . . . . . .10A

PM 12 . . . . . . . . . . . . . . . . . .10A

N4X-FG-141206CHQR . . . . . . .2A

PBO-AMCGN-FS . . . . . . . . . . .7A

PEM 10 . . . . . . . . . . . . . . . . .10A

PM 14 . . . . . . . . . . . . . . . . . .10A

N4X-FG-141206CHSC . . . . . . .2A

PBO-AMCGN-FS/FS . . . . . . . .7A

PEM 12 . . . . . . . . . . . . . . . . .10A

PM 16 . . . . . . . . . . . . . . . . . .10A

N4X-FG-141206CHTL . . . . . . .2A

PBO-AMCRD-FS . . . . . . . . . . .7A

PEM 14 . . . . . . . . . . . . . . . . .10A

PM 2 . . . . . . . . . . . . . . . . . . .10A

N4X-FG-141206SC . . . . . . . . .2A

PBO-AMCRD-FS/FS . . . . . . . .7A

PEM 16 . . . . . . . . . . . . . . . . .10A

PM 20 . . . . . . . . . . . . . . . . . .10A

N4X-FG-141207RCHQR . . . . .2A

PBO-AXCBK-FS . . . . . . . . . . . .7A

PEM 2 . . . . . . . . . . . . . . . . . .10A

PM 24 . . . . . . . . . . . . . . . . . .10A

N4X-FG-141207RCHTL . . . . . .2A

PBO-AXCBK-FS/FS . . . . . . . . .7A

PEM 3 . . . . . . . . . . . . . . . . . .10A

PM 3 . . . . . . . . . . . . . . . . . . .10A

N4X-FG-161406CHQR . . . . . . .2A

PBO-AXCGN-FS . . . . . . . . . . .7A

PEM 4 . . . . . . . . . . . . . . . . . .10A

PM 4 . . . . . . . . . . . . . . . . . . .10A

N4X-FG-161406CHSC . . . . . . .2A

PBO-AXCGN-FS/FS . . . . . . . . .7A

PEM 5 . . . . . . . . . . . . . . . . . .10A

PM 5 . . . . . . . . . . . . . . . . . . .10A

N4X-FG-161406CHTL . . . . . . .2A

PBO-AXCRD-FS . . . . . . . . . . .7A

PEM 6 . . . . . . . . . . . . . . . . . .10A

PM 6 . . . . . . . . . . . . . . . . . . .10A

N4X-FG-161407RCHQR . . . . .2A

PBO-AXCRD-FS/FS . . . . . . . . .7A

PEM 8 . . . . . . . . . . . . . . . . . .10A

PM 8 . . . . . . . . . . . . . . . . . . .10A

N4X-FG-161407RCHTL . . . . . .2A

PBO-FCBK-FS . . . . . . . . . . . . .7A

PEML 10 . . . . . . . . . . . . . . . .10A

PS 065-05 . . . . . . . . . . . . . . .11A

N4X-FG-181608CHQR . . . . . . .2A

PBO-FCBK-FS/FS . . . . . . . . . .7A

PEML 12 . . . . . . . . . . . . . . . .10A

PS 075-05 . . . . . . . . . . . . . . .11A

N4X-FG-181608CHSC . . . . . . .2A

PBO-FCGN-FS . . . . . . . . . . . . .7A

PEML 14 . . . . . . . . . . . . . . . .10A

PS 085-05 . . . . . . . . . . . . . . .11A

N4X-FG-181608CHTL . . . . . . .2A

PBO-FCGN-FS/FS . . . . . . . . . .7A

PEML 16 . . . . . . . . . . . . . . . .10A

PS 100-07 . . . . . . . . . . . . . . .11A

N4X-FG-181610RCHQR . . . . .2A

PBO-FCRD-FS . . . . . . . . . . . . .7A

PEML 2 . . . . . . . . . . . . . . . . .10A

PS 115-07 . . . . . . . . . . . . . . .11A

N4X-FG-181610RCHTL . . . . . .2A

PBO-FCRD-FS/FS . . . . . . . . . .7A

PEML 3 . . . . . . . . . . . . . . . . .10A

PS 125-10 . . . . . . . . . . . . . . .11A

N4X-FG-1PB . . . . . . . . . . . . . .2A

PBO-MCBK-FS . . . . . . . . . . . .7A

PEML 4 . . . . . . . . . . . . . . . . .10A

PS 138-10 . . . . . . . . . . . . . . .11A

N4X-FG-201606CH . . . . . . . . .2A

PBO-MCBK-FS/FS . . . . . . . . . .7A

PEML 5 . . . . . . . . . . . . . . . . .10A

PS 150-12 . . . . . . . . . . . . . . .11A

364
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 365

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

PS 168-12 . . . . . . . . . . . . . . .11A

RLU120I . . . . . . . . . . . . . . . . .7A

SROLR-SHWE-FS/FS . . . . . . .7A

TFG-100804H . . . . . . . . . . . . .3B

PS 183-15 . . . . . . . . . . . . . . .11A

RLU120IFS . . . . . . . . . . . . . . .7A

SROLR-SLWE-FS . . . . . . . . . .7A

TFG-100804I . . . . . . . . . . . . . .3E

PS 200-15 . . . . . . . . . . . . . . .11A

RLU120L . . . . . . . . . . . . . . . .7A

SROLR-SLWE-FS/FS . . . . . . . .7A

TFG-100806 . . . . . . . . . . . . . .3B

PS 218-15 . . . . . . . . . . . . . . .11A

RLU120LFS . . . . . . . . . . . . . .7A

SRORC-SHWE-FS . . . . . . . . . .7A

TFG-100806H . . . . . . . . . . . . .3B

PSX 065-05 . . . . . . . . . . . . . .11A

RLU240I . . . . . . . . . . . . . . . . .7A

SRORC-SHWE-FS/FS . . . . . . .7A

TFG-100806I . . . . . . . . . . . . . .3E

PSX 075-05 . . . . . . . . . . . . . .11A

RLU240IFS . . . . . . . . . . . . . . .7A

SRORC-SLWE-FS . . . . . . . . . .7A

TFG-121005 . . . . . . . . . . . . . .3B

PSX 085-05 . . . . . . . . . . . . . .11A

RLU240L . . . . . . . . . . . . . . . .7A

SRORC-SLWE-FS/FS . . . . . . . .7A

TFG-121005H . . . . . . . . . . . . .3B

PSX 100-07 . . . . . . . . . . . . . .11A

RLU240LFS . . . . . . . . . . . . . .7A

SRORL-SHWE-FS . . . . . . . . . .7A

TFG-121005I . . . . . . . . . . . . . .3E

PSX 115-07 . . . . . . . . . . . . . .11A

RLU240N . . . . . . . . . . . . . . . .7A

SRORL-SHWE-FS/FS . . . . . . .7A

TFG-121006 . . . . . . . . . . . . . .3B

PSX 125-10 . . . . . . . . . . . . . .11A

RLU240NFS . . . . . . . . . . . . . .7A

SRORL-SLWE-FS . . . . . . . . . .7A

TFG-121006H . . . . . . . . . . . . .3B

PSX 138-10 . . . . . . . . . . . . . .11A

RLU480N . . . . . . . . . . . . . . . .7A

SRORL-SLWE-FS/FS . . . . . . . .7A

TFG-121006I . . . . . . . . . . . . . .3E

PSX 150-12 . . . . . . . . . . . . . .11A

RLU480NFS . . . . . . . . . . . . . .7A

SSF-2 . . . . . . . . . . . . . . . . . .11A

TFG-141206 . . . . . . . . . . . . . .3B

PSX 168-12 . . . . . . . . . . . . . .11A

Round yellow emergency stop 7A

SSO2-SHWE-FS . . . . . . . . . . .7A

TFG-141206H . . . . . . . . . . . . .3B

PSX 183-15 . . . . . . . . . . . . . .11A

RTLU120 . . . . . . . . . . . . . . . . .7A

SSO2-SHWE-FS/FS . . . . . . . . .7A

TFG-141206I . . . . . . . . . . . . . .3E

PSX 200-15 . . . . . . . . . . . . . .11A

RTLU120FS . . . . . . . . . . . . . . .7A

SSO2-SLWE-FS . . . . . . . . . . . .7A

TFG-141207 . . . . . . . . . . . . . .3B

PSX 218-15 . . . . . . . . . . . . . .11A

RTLU240 . . . . . . . . . . . . . . . . .7A

SSO2-SLWE-FS/FS . . . . . . . . .7A

TFG-141207H . . . . . . . . . . . . .3B

PT 1000-D . . . . . . . . . . . . . . .11A

RTLU240FS . . . . . . . . . . . . . . .7A

SSO3-SHWE-FS . . . . . . . . . . .7A

TFG-141207I . . . . . . . . . . . . . .3E

PT 10-B . . . . . . . . . . . . . . . . .11A

SA 42 . . . . . . . . . . . . . . . . . .10A

SSO3-SHWE-FS/FS . . . . . . . . .7A

TFG-161406 . . . . . . . . . . . . . .3B

PT 1-B . . . . . . . . . . . . . . . . . .11A

SD . . . . . . . . . . . . . . . . . . . .11A

SSO3-SLWE-FS . . . . . . . . . . . .7A

TFG-161406H . . . . . . . . . . . . .3B

PT 20-B . . . . . . . . . . . . . . . . .11A

SE-15 . . . . . . . . . . . . . . . . . .11A

SSO3-SLWE-FS/FS . . . . . . . . .7A

TFG-161406I . . . . . . . . . . . . . .3E

PT 250-C . . . . . . . . . . . . . . . .11A

SE-16 . . . . . . . . . . . . . . . . . .11A

SSR . . . . . . . . . . . . . . . . . . .11A

TFG-161407 . . . . . . . . . . . . . .3B

PT 2-B . . . . . . . . . . . . . . . . . .11A

SE-25 . . . . . . . . . . . . . . . . . .11A

SW 5050 . . . . . . . . . . . . . . . .11A

TFG-161407H . . . . . . . . . . . . .3B

PT 300-C . . . . . . . . . . . . . . . .11A

SE-35 . . . . . . . . . . . . . . . . . .11A

TAP 2015 . . . . . . . . . . . . . . .11A

TFG-161407I . . . . . . . . . . . . . .3E

PT 30-B . . . . . . . . . . . . . . . . .11A

SE-5 . . . . . . . . . . . . . . . . . . .11A

TAP 2030 . . . . . . . . . . . . . . .11A

TFG-181608 . . . . . . . . . . . . . .3B

PT 350-C . . . . . . . . . . . . . . . .11A

SE-8 . . . . . . . . . . . . . . . . . . .11A

TCK-35 . . . . . . . . . . . . . . . . .11A

TFG-181608H . . . . . . . . . . . . .3B

PT 400-C . . . . . . . . . . . . . . . .11A

SG-1 . . . . . . . . . . . . . . . . . . .11A

TCT-2705 . . . . . . . . . . . . . . . .11A

TFG-181608I . . . . . . . . . . . . . .3E

PT 40-C . . . . . . . . . . . . . . . . .11A

SH 1125 . . . . . . . . . . . . . . . .10A

TCY-8025 . . . . . . . . . . . . . . .11A

TFG-181610 . . . . . . . . . . . . . .3B

PT 4-B . . . . . . . . . . . . . . . . . .11A

SH 50 . . . . . . . . . . . . . . . . . .10A

TFA 45-25 . . . . . . . . . . . . . . .11A

TFG-181610H . . . . . . . . . . . . .3B

PT 500-C . . . . . . . . . . . . . . . .11A

SH 75 . . . . . . . . . . . . . . . . . .10A

TFA 45-30 . . . . . . . . . . . . . . .11A

TFG-181610I . . . . . . . . . . . . . .3E

PT 600-D . . . . . . . . . . . . . . . .11A

SHD 50 . . . . . . . . . . . . . . . . .10A

TFA 45-35 . . . . . . . . . . . . . . .11A

TFG-201608 . . . . . . . . . . . . . .3B

PT 6-B . . . . . . . . . . . . . . . . . .11A

SHD 75 . . . . . . . . . . . . . . . . .10A

TFA 45-40 . . . . . . . . . . . . . . .11A

TFG-201608H . . . . . . . . . . . . .3B

PT 700-D . . . . . . . . . . . . . . . .11A

SHS 1125 . . . . . . . . . . . . . . .10A

TFA 45-50 . . . . . . . . . . . . . . .11A

TFG-201608I . . . . . . . . . . . . . .3E

PT 750-D . . . . . . . . . . . . . . . .11A

SHS 50 . . . . . . . . . . . . . . . . .10A

TFA 45-60 . . . . . . . . . . . . . . .11A

TFG-201610 . . . . . . . . . . . . . .3B

PT 8-B . . . . . . . . . . . . . . . . . .11A

SHS 75 . . . . . . . . . . . . . . . . .10A

TFG-060404 . . . . . . . . . . . . . .3B

TFG-201610H . . . . . . . . . . . . .3B

PTR-TMCBK-FS . . . . . . . . . . . .7A

SPE 2 . . . . . . . . . . . . . . . . . .10A

TFG-060404H . . . . . . . . . . . . .3B

TFG-201610I . . . . . . . . . . . . . .3E

PTR-TMCBK-FS/FS . . . . . . . . .7A

SPE 3 . . . . . . . . . . . . . . . . . .10A

TFG-060406 . . . . . . . . . . . . . .3B

TFLU120 . . . . . . . . . . . . . . . . .7A

PTR-TMCGN-FS . . . . . . . . . . .7A

SPE 4 . . . . . . . . . . . . . . . . . .10A

TFG-060406H . . . . . . . . . . . . .3B

TFLU120FS . . . . . . . . . . . . . . .7A

PTR-TMCGN-FS/FS . . . . . . . . .7A

SPE 5 . . . . . . . . . . . . . . . . . .10A

TFG-060604 . . . . . . . . . . . . . .3B

TFLU240 . . . . . . . . . . . . . . . . .7A

PTR-TMCRD-FS . . . . . . . . . . .7A

SPE 6 . . . . . . . . . . . . . . . . . .10A

TFG-060604H . . . . . . . . . . . . .3B

TFLU240FS . . . . . . . . . . . . . . .7A

PTR-TMCRD-FS/FS . . . . . . . . .7A

SPE 8 . . . . . . . . . . . . . . . . . .10A

TFG-060604I . . . . . . . . . . . . . .3E

TFLU277 . . . . . . . . . . . . . . . . .7A

PTR-TMCYW-FS . . . . . . . . . . .7A

SPLICING BOOK . . . . . . . . . .11A

TFG-060606 . . . . . . . . . . . . . .3B

TFLU277FS . . . . . . . . . . . . . . .7A

PTR-TMCYW-FS/FS . . . . . . . . .7A

SROLC-SHWE-FS . . . . . . . . . .7A

TFG-060606H . . . . . . . . . . . . .3B

TFLU480 . . . . . . . . . . . . . . . . .7A

RA1 . . . . . . . . . . . . . . . . . . . .7C

SROLC-SHWE-FS/FS . . . . . . .7A

TFG-060606I . . . . . . . . . . . . . .3E

TFLU480FS . . . . . . . . . . . . . . .7A

RC-1 . . . . . . . . . . . . . . . . . . .11A

SROLC-SLWE-FS . . . . . . . . . .7A

TFG-080604 . . . . . . . . . . . . . .3B

TFPPM120-IMCRD-FS . . . . . .7A

RLPPM120I-IMCRD-FS . . . . . .7A

SROLC-SLWE-FS/FS . . . . . . . .7A

TFG-080604H . . . . . . . . . . . . .3B

TFPPM120-IMCRD-FS/FS . . . .7A

RLPPM120I-IMCRD-FS/FS . . .7A

SROLRC-SHWE-FS . . . . . . . . .7A

TFG-080604I . . . . . . . . . . . . . .3E

TFPPM240-IMCRD-FS . . . . . .7A

RLPPM240I-IMCRD-FS . . . . . .7A

SROLRC-SHWE-FS/FS . . . . . .7A

TFG-080606 . . . . . . . . . . . . . .3B

TFPPM240-IMCRD-FS/FS . . . .7A

RLPPM240I-IMCRD-FS/FS . . .7A

SROLRC-SLWE-FS . . . . . . . . .7A

TFG-080606H . . . . . . . . . . . . .3B

TFPPM480-IMCRD-FS . . . . . .7A

RLPTT120IFS . . . . . . . . . . . . .7A

SROLRC-SLWE-FS/FS . . . . . . .7A

TFG-080606I . . . . . . . . . . . . . .3E

TFPPM480-IMCRD-FS/FS . . . .7A

RLPTT120LFS . . . . . . . . . . . . .7A

SROLR-SHWE-FS . . . . . . . . . .7A

TFG-100804 . . . . . . . . . . . . . .3B

TFPPM600-IMCRD-FS . . . . . .7A

365
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 366

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

TFPPM600-IMCRD-FS/FS . . . .7A

TN4X6-242012 . . . . . . . . . . . .3B

TN4X6-363008 . . . . . . . . . . . .3B

TSC4-101006 . . . . . . . . . . . . .3B

TFPTT120FS . . . . . . . . . . . . . .7A

TN4X6-242016 . . . . . . . . . . . .3B

TN4X6-363010 . . . . . . . . . . . .3B

TSC4-101008 . . . . . . . . . . . . .3B

TFPTT240FS . . . . . . . . . . . . . .7A

TN4X6-242406 . . . . . . . . . . . .3B

TN4X6-363012 . . . . . . . . . . . .3B

TSC4-120604 . . . . . . . . . . . . .3B

TFPTT480FS . . . . . . . . . . . . . .7A

TN4X6-242408 . . . . . . . . . . . .3B

TN4X6-363016 . . . . . . . . . . . .3B

TSC4-120605 . . . . . . . . . . . . .3B

TFT-6015 . . . . . . . . . . . . . . . .11A

TN4X6-242410 . . . . . . . . . . . .3B

TN4X6-363020 . . . . . . . . . . . .3B

TSC4-120805 . . . . . . . . . . . . .3B

TFT-6020 . . . . . . . . . . . . . . . .11A

TN4X6-242412 . . . . . . . . . . . .3B

TN4X6-363608 . . . . . . . . . . . .3B

TSC4-120806 . . . . . . . . . . . . .3B

TFT-6575 . . . . . . . . . . . . . . . .11A

TN4X6-242416 . . . . . . . . . . . .3B

TN4X6-363612 . . . . . . . . . . . .3B

TSC4-121206 . . . . . . . . . . . . .3B

TGB-10025 . . . . . . . . . . . . . .11A

TN4X6-243008 . . . . . . . . . . . .3B

TN4X6-392907 . . . . . . . . . . . .3B

TSC4-121208 . . . . . . . . . . . . .3B

TGB-10050 . . . . . . . . . . . . . .11A

TN4X6-251807 . . . . . . . . . . . .3B

TN4X6-392907-A . . . . . . . . . . .3B

TSC4-151506 . . . . . . . . . . . . .3B

TGB-20025 . . . . . . . . . . . . . .11A

TN4X6-251807-A . . . . . . . . . . .3B

TN4X6-392907-AB . . . . . . . . .3B

TSC4-151508 . . . . . . . . . . . . .3B

THVT-3010 . . . . . . . . . . . . . .11A

TN4X6-251807-AB . . . . . . . . .3B

TN4X6-392907-ABCD . . . . . . .3B

TSC4-161206 . . . . . . . . . . . . .3B

THVT-3015 . . . . . . . . . . . . . .11A

TN4X6-251807-ABCD . . . . . . .3B

TN4X6-392907-B . . . . . . . . . . .3B

TSC4-161208 . . . . . . . . . . . . .3B

THVT-3020 . . . . . . . . . . . . . .11A

TN4X6-251807-B . . . . . . . . . . .3B

TN4X6-392907-C . . . . . . . . . . .3B

TSC4-161606 . . . . . . . . . . . . .3B

THVT-3075 . . . . . . . . . . . . . .11A

TN4X6-251807-C . . . . . . . . . . .3B

TN4X6-392907-CD . . . . . . . . .3B

TSC4-161608 . . . . . . . . . . . . .3B

TN4X6-122406 . . . . . . . . . . . .3B

TN4X6-251807-CD . . . . . . . . .3B

TN4X6-392907-D . . . . . . . . . . .3B

TSC4X-050503 . . . . . . . . . . . .3B

TN4X6-122408 . . . . . . . . . . . .3B

TN4X6-251807-D . . . . . . . . . . .3B

TN4X6-422408 . . . . . . . . . . . .3B

TSC4X-060604 . . . . . . . . . . . .3B

TN4X6-161206 . . . . . . . . . . . .3B

TN4X6-301606 . . . . . . . . . . . .3B

TN4X6-423008 . . . . . . . . . . . .3B

TSC4X-070704 . . . . . . . . . . . .3B

TN4X6-161208 . . . . . . . . . . . .3B

TN4X6-302006 . . . . . . . . . . . .3B

TN4X6-423012 . . . . . . . . . . . .3B

TSC4X-080804 . . . . . . . . . . . .3B

TN4X6-161210 . . . . . . . . . . . .3B

TN4X6-302008 . . . . . . . . . . . .3B

TN4X6-423608 . . . . . . . . . . . .3B

TSC4X-101006 . . . . . . . . . . . .3B

TN4X6-161606 . . . . . . . . . . . .3B

TN4X6-302010 . . . . . . . . . . . .3B

TN4X6-423612 . . . . . . . . . . . .3B

TSC4X-101008 . . . . . . . . . . . .3B

TN4X6-161608 . . . . . . . . . . . .3B

TN4X6-302207 . . . . . . . . . . . .3B

TN4X6-423616 . . . . . . . . . . . .3B

TSC4X-120604 . . . . . . . . . . . .3B

TN4X6-162006 . . . . . . . . . . . .3B

TN4X6-302207-A . . . . . . . . . . .3B

TN4X6-482408 . . . . . . . . . . . .3B

TSC4X-120605 . . . . . . . . . . . .3B

TN4X6-162008 . . . . . . . . . . . .3B

TN4X6-302207-AB . . . . . . . . .3B

TN4X6-483008 . . . . . . . . . . . .3B

TSC4X-120805 . . . . . . . . . . . .3B

TN4X6-201206 . . . . . . . . . . . .3B

TN4X6-302207-ABCD . . . . . . .3B

TN4X6-483010 . . . . . . . . . . . .3B

TSC4X-120806 . . . . . . . . . . . .3B

TN4X6-201208 . . . . . . . . . . . .3B

TN4X6-302207-B . . . . . . . . . . .3B

TN4X6-483608 . . . . . . . . . . . .3B

TSC4X-121206 . . . . . . . . . . . .3B

TN4X6-201407 . . . . . . . . . . . .3B

TN4X6-302207-C . . . . . . . . . . .3B

TN4X6-483610 . . . . . . . . . . . .3B

TSC4X-121208 . . . . . . . . . . . .3B

TN4X6-201407-A . . . . . . . . . . .3B

TN4X6-302207-CD . . . . . . . . .3B

TN4X6-483612 . . . . . . . . . . . .3B

TSC4X-151506 . . . . . . . . . . . .3B

TN4X6-201407-AB . . . . . . . . .3B

TN4X6-302207-D . . . . . . . . . . .3B

TN4X6-483616 . . . . . . . . . . . .3B

TSC4X-151508 . . . . . . . . . . . .3B

TN4X6-201407-ABCD . . . . . . .3B

TN4X6-302406 . . . . . . . . . . . .3B

TN4X6-483620 . . . . . . . . . . . .3B

TSC4X-161206 . . . . . . . . . . . .3B

TN4X6-201407-B . . . . . . . . . . .3B

TN4X6-302408 . . . . . . . . . . . .3B

TN4X6-483624 . . . . . . . . . . . .3B

TSC4X-161208 . . . . . . . . . . . .3B

TN4X6-201407-C . . . . . . . . . . .3B

TN4X6-302410 . . . . . . . . . . . .3B

TN4X6-603608 . . . . . . . . . . . .3B

TSC4X-161606 . . . . . . . . . . . .3B

TN4X6-201407-CD . . . . . . . . .3B

TN4X6-302412 . . . . . . . . . . . .3B

TN4X6-603610 . . . . . . . . . . . .3B

TSC4X-161608 . . . . . . . . . . . .3B

TN4X6-201407-D . . . . . . . . . . .3B

TN4X6-302416 . . . . . . . . . . . .3B

TN4X6-603612 . . . . . . . . . . . .3B

TSC4X6-050503 . . . . . . . . . . .3B

TN4X6-201606 . . . . . . . . . . . .3B

TN4X6-302420 . . . . . . . . . . . .3B

TN4X6-603616 . . . . . . . . . . . .3B

TSC4X6-060604 . . . . . . . . . . .3B

TN4X6-201608 . . . . . . . . . . . .3B

TN4X6-303008 . . . . . . . . . . . .3B

TN4X6-603620 . . . . . . . . . . . .3B

TSC4X6-060604I . . . . . . . . . . .3E

TN4X6-201610 . . . . . . . . . . . .3B

TN4X6-303012 . . . . . . . . . . . .3B

TN4X6-603624 . . . . . . . . . . . .3B

TSC4X6-070704 . . . . . . . . . . .3B

TN4X6-201612 . . . . . . . . . . . .3B

TN4X6-303608 . . . . . . . . . . . .3B

TNJ-3010 . . . . . . . . . . . . . . .11A

TSC4X6-070704I . . . . . . . . . . .3E

TN4X6-202006 . . . . . . . . . . . .3B

TN4X6-362406 . . . . . . . . . . . .3B

TNJ-3015 . . . . . . . . . . . . . . .11A

TSC4X6-080804 . . . . . . . . . . .3B

TN4X6-202008 . . . . . . . . . . . .3B

TN4X6-362408 . . . . . . . . . . . .3B

TNJ-3020 . . . . . . . . . . . . . . .11A

TSC4X6-080804I . . . . . . . . . . .3E

TN4X6-202010 . . . . . . . . . . . .3B

TN4X6-362410 . . . . . . . . . . . .3B

TNJ-3075 . . . . . . . . . . . . . . .11A

TSC4X6-101006 . . . . . . . . . . .3B

TN4X6-202406 . . . . . . . . . . . .3B

TN4X6-362412 . . . . . . . . . . . .3B

TPVC 20 . . . . . . . . . . . . . . . .11A

TSC4X6-101006I . . . . . . . . . . .3E

TN4X6-202408 . . . . . . . . . . . .3B

TN4X6-362507 . . . . . . . . . . . .3B

TPVC 66 . . . . . . . . . . . . . . . .11A

TSC4X6-101008 . . . . . . . . . . .3B

TN4X6-241206 . . . . . . . . . . . .3B

TN4X6-362507-A . . . . . . . . . . .3B

TSB 100 . . . . . . . . . . . . . . . .11A

TSC4X6-101008I . . . . . . . . . . .3E

TN4X6-241208 . . . . . . . . . . . .3B

TN4X6-362507-AB . . . . . . . . .3B

TSB 15 . . . . . . . . . . . . . . . . .11A

TSC4X6-120604 . . . . . . . . . . .3B

TN4X6-241210 . . . . . . . . . . . .3B

TN4X6-362507-ABCD . . . . . . .3B

TSB 432 . . . . . . . . . . . . . . . .11A

TSC4X6-120604I . . . . . . . . . . .3E

TN4X6-241606 . . . . . . . . . . . .3B

TN4X6-362507-B . . . . . . . . . . .3B

TSC 15 . . . . . . . . . . . . . . . . .11A

TSC4X6-120605 . . . . . . . . . . .3B

TN4X6-241608 . . . . . . . . . . . .3B

TN4X6-362507-C . . . . . . . . . . .3B

TSC4-050503 . . . . . . . . . . . . .3B

TSC4X6-120605I . . . . . . . . . . .3E

TN4X6-242006 . . . . . . . . . . . .3B

TN4X6-362507-CD . . . . . . . . .3B

TSC4-060604 . . . . . . . . . . . . .3B

TSC4X6-120805 . . . . . . . . . . .3B

TN4X6-242008 . . . . . . . . . . . .3B

TN4X6-362507-D . . . . . . . . . . .3B

TSC4-070704 . . . . . . . . . . . . .3B

TSC4X6-120805I . . . . . . . . . . .3E

TN4X6-242010 . . . . . . . . . . . .3B

TN4X6-363006 . . . . . . . . . . . .3B

TSC4-080804 . . . . . . . . . . . . .3B

TSC4X6-120806 . . . . . . . . . . .3B

366
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 367

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

TSC4X6-120806I . . . . . . . . . . .3E

WIF 164810 . . . . . . . . . . . . . .5B

X 82 XDC . . . . . . . . . . . . . . . .5E

X2FG-1B2 . . . . . . . . . . . . . . . .7A

TSC4X6-121206 . . . . . . . . . . .3B

WIF 202408 . . . . . . . . . . . . . .5B

X 82 XDC N4 . . . . . . . . . . . . . .5E

X2FG-1B3 . . . . . . . . . . . . . . . .7A

TSC4X6-121206I . . . . . . . . . . .3E

WIF 202412 . . . . . . . . . . . . . .5B

X 8230 . . . . . . . . . . . . . . . . . .5E

X2FG-1B4 . . . . . . . . . . . . . . . .7A

TSC4X6-121208 . . . . . . . . . . .3B

WIF 242414 . . . . . . . . . . . . . .5B

X 83 . . . . . . . . . . . . . . . . . . . .5E

X2FG-1F2 . . . . . . . . . . . . . . . .7A

TSC4X6-121208I . . . . . . . . . . .3E

WIF 243608 . . . . . . . . . . . . . .5B

X 83 C . . . . . . . . . . . . . . . . . . .5E

X2FG-1F3 . . . . . . . . . . . . . . . .7A

TSC4X6-151506 . . . . . . . . . . .3B

WIF 364808 . . . . . . . . . . . . . .5B

X 83 N4 . . . . . . . . . . . . . . . . . .5E

X2FG-1F4 . . . . . . . . . . . . . . . .7A

TSC4X6-151506I . . . . . . . . . . .3E

WJF 061105 . . . . . . . . . . . . . .5A

X 83 XDC . . . . . . . . . . . . . . . .5E

X2FG-1T2 . . . . . . . . . . . . . . . .7A

TSC4X6-151508 . . . . . . . . . . .3B

WJF 061305 . . . . . . . . . . . . . .5A

X 83 XDC N4 . . . . . . . . . . . . . .5E

X2FG-1T3 . . . . . . . . . . . . . . . .7A

TSC4X6-151508I . . . . . . . . . . .3E

WJF 071805 . . . . . . . . . . . . . .5A

X 8P . . . . . . . . . . . . . . . . . . . .7B

X2FG-1T4 . . . . . . . . . . . . . . . .7A

TSC4X6-161206 . . . . . . . . . . .3B

WJF 121806 . . . . . . . . . . . . . .5A

X2CS-1 . . . . . . . . . . . . . . . . . .7A

X2FG-2 . . . . . . . . . . . . . . . . . .7A

TSC4X6-161206I . . . . . . . . . . .3E

WJF 122005 . . . . . . . . . . . . . .5A

X2CS-1B2 . . . . . . . . . . . . . . . .7A

X2FG-2B2 . . . . . . . . . . . . . . . .7A

TSC4X6-161208 . . . . . . . . . . .3B

WJF 122406 . . . . . . . . . . . . . .5A

X2CS-1B3 . . . . . . . . . . . . . . . .7A

X2FG-2B3 . . . . . . . . . . . . . . . .7A

TSC4X6-161208I . . . . . . . . . . .3E

WJF 122408 . . . . . . . . . . . . . .5A

X2CS-1B4 . . . . . . . . . . . . . . . .7A

X2FG-2B4 . . . . . . . . . . . . . . . .7A

TSC4X6-161606 . . . . . . . . . . .3B

WJF 123006 . . . . . . . . . . . . . .5A

X2CS-1F2 . . . . . . . . . . . . . . . .7A

X2FG-2F2 . . . . . . . . . . . . . . . .7A

TSC4X6-161606I . . . . . . . . . . .3E

WJF 123208 . . . . . . . . . . . . . .5A

X2CS-1F3 . . . . . . . . . . . . . . . .7A

X2FG-2F3 . . . . . . . . . . . . . . . .7A

TSC4X6-161608 . . . . . . . . . . .3B

WJF 123608 . . . . . . . . . . . . . .5A

X2CS-1F4 . . . . . . . . . . . . . . . .7A

X2FG-2F4 . . . . . . . . . . . . . . . .7A

TSC4X6-161608I . . . . . . . . . . .3E

WSG . . . . . . . . . . . . . . . . . . . .5E

X2CS-1T2 . . . . . . . . . . . . . . . .7A

X2FG-2T2 . . . . . . . . . . . . . . . .7A

TSIL 30 . . . . . . . . . . . . . . . . .11A

WSO . . . . . . . . . . . . . . . . . . . .5E

X2CS-1T3 . . . . . . . . . . . . . . . .7A

X2FG-2T3 . . . . . . . . . . . . . . . .7A

TVD 1205 . . . . . . . . . . . . . . .11A

WTB-1 . . . . . . . . . . . . . . . . .11A

X2CS-1T4 . . . . . . . . . . . . . . . .7A

X2FG-2T4 . . . . . . . . . . . . . . . .7A

TVD 1210 . . . . . . . . . . . . . . .11A

WTB-2 . . . . . . . . . . . . . . . . .11A

X2CS-2 . . . . . . . . . . . . . . . . . .7A

X2FG-3 . . . . . . . . . . . . . . . . . .7A

TVD 1275 . . . . . . . . . . . . . . .11A

WTB-3 . . . . . . . . . . . . . . . . .11A

X2CS-2B2 . . . . . . . . . . . . . . . .7A

X2FG-3B2 . . . . . . . . . . . . . . . .7A

TVD 4810 . . . . . . . . . . . . . . .11A

X 1 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-2B3 . . . . . . . . . . . . . . . .7A

X2FG-3B3 . . . . . . . . . . . . . . . .7A

TVD 5475 . . . . . . . . . . . . . . .11A

X 12 . . . . . . . . . . . . . . . . . . . .7B

X2CS-2B4 . . . . . . . . . . . . . . . .7A

X2FG-3B4 . . . . . . . . . . . . . . . .7A

V-1212 . . . . . . . . . . . . . . . . . .1C

X 12P . . . . . . . . . . . . . . . . . . .7B

X2CS-2F2 . . . . . . . . . . . . . . . .7A

X2FG-3F2 . . . . . . . . . . . . . . . .7A

V-1612 . . . . . . . . . . . . . . . . . .1C

X 15 . . . . . . . . . . . . . . . . . . . .7B

X2CS-2F3 . . . . . . . . . . . . . . . .7A

X2FG-3F3 . . . . . . . . . . . . . . . .7A

V-1616 . . . . . . . . . . . . . . . . . .1C

X 15P . . . . . . . . . . . . . . . . . . .7B

X2CS-2F4 . . . . . . . . . . . . . . . .7A

X2FG-3F4 . . . . . . . . . . . . . . . .7A

V-2016 . . . . . . . . . . . . . . . . . .1C

X 18 . . . . . . . . . . . . . . . . . . . .7B

X2CS-2T2 . . . . . . . . . . . . . . . .7A

X2FG-3T2 . . . . . . . . . . . . . . . .7A

V-2020 . . . . . . . . . . . . . . . . . .1C

X 18P . . . . . . . . . . . . . . . . . . .7B

X2CS-2T3 . . . . . . . . . . . . . . . .7A

X2FG-3T3 . . . . . . . . . . . . . . . .7A

V-2412 . . . . . . . . . . . . . . . . . .1C

X 1P . . . . . . . . . . . . . . . . . . . .7B

X2CS-2T4 . . . . . . . . . . . . . . . .7A

X2FG-3T4 . . . . . . . . . . . . . . . .7A

V-2416 . . . . . . . . . . . . . . . . . .1C

X 2 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-3 . . . . . . . . . . . . . . . . . .7A

X2FG-4 . . . . . . . . . . . . . . . . . .7A

V-2420 . . . . . . . . . . . . . . . . . .1C

X 2P . . . . . . . . . . . . . . . . . . . .7B

X2CS-3B2 . . . . . . . . . . . . . . . .7A

X2FG-4B2 . . . . . . . . . . . . . . . .7A

V-2424 . . . . . . . . . . . . . . . . . .1C

X 3 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-3B3 . . . . . . . . . . . . . . . .7A

X2FG-4B3 . . . . . . . . . . . . . . . .7A

V-3020 . . . . . . . . . . . . . . . . . .1C

X 3P . . . . . . . . . . . . . . . . . . . .7B

X2CS-3B4 . . . . . . . . . . . . . . . .7A

X2FG-4B4 . . . . . . . . . . . . . . . .7A

V-3024 . . . . . . . . . . . . . . . . . .1C

X 4 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-3F2 . . . . . . . . . . . . . . . .7A

X2FG-4F2 . . . . . . . . . . . . . . . .7A

V-3030 . . . . . . . . . . . . . . . . . .1C

X 4P . . . . . . . . . . . . . . . . . . . .7B

X2CS-3F3 . . . . . . . . . . . . . . . .7A

X2FG-4F3 . . . . . . . . . . . . . . . .7A

V-3624 . . . . . . . . . . . . . . . . . .1C

X 5 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-3F4 . . . . . . . . . . . . . . . .7A

X2FG-4F4 . . . . . . . . . . . . . . . .7A

V-3630 . . . . . . . . . . . . . . . . . .1C

X 5P . . . . . . . . . . . . . . . . . . . .7B

X2CS-3T2 . . . . . . . . . . . . . . . .7A

X2FG-4T2 . . . . . . . . . . . . . . . .7A

V-3636 . . . . . . . . . . . . . . . . . .1C

X 6 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-3T3 . . . . . . . . . . . . . . . .7A

X2FG-4T3 . . . . . . . . . . . . . . . .7A

V-4230 . . . . . . . . . . . . . . . . . .1C

X 643 . . . . . . . . . . . . . . . . . . .5E

X2CS-3T4 . . . . . . . . . . . . . . . .7A

X2FG-4T4 . . . . . . . . . . . . . . . .7A

V-4236 . . . . . . . . . . . . . . . . . .1C

X 643 C . . . . . . . . . . . . . . . . . .5E

X2CS-4 . . . . . . . . . . . . . . . . . .7A

X2SS-1 . . . . . . . . . . . . . . . . . .7A

V-4836 . . . . . . . . . . . . . . . . . .1C

X 643 N4 . . . . . . . . . . . . . . . . .5E

X2CS-4B2 . . . . . . . . . . . . . . . .7A

X2SS-1B2 . . . . . . . . . . . . . . . .7A

V-6036 . . . . . . . . . . . . . . . . . .1C

X 643 XDC . . . . . . . . . . . . . . .5E

X2CS-4B3 . . . . . . . . . . . . . . . .7A

X2SS-1B3 . . . . . . . . . . . . . . . .7A

WACS 238 . . . . . . . . . . . . . .11A

X 643 XDC N4 . . . . . . . . . . . . .5E

X2CS-4B4 . . . . . . . . . . . . . . . .7A

X2SS-1B4 . . . . . . . . . . . . . . . .7A

WACS 288 . . . . . . . . . . . . . .11A

X 6P . . . . . . . . . . . . . . . . . . . .7B

X2CS-4F2 . . . . . . . . . . . . . . . .7A

X2SS-1F2 . . . . . . . . . . . . . . . .7A

WACS 330 . . . . . . . . . . . . . .11A

X 7 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-4F3 . . . . . . . . . . . . . . . .7A

X2SS-1F3 . . . . . . . . . . . . . . . .7A

WACS 338 . . . . . . . . . . . . . .11A

X 7P . . . . . . . . . . . . . . . . . . . .7B

X2CS-4F4 . . . . . . . . . . . . . . . .7A

X2SS-1F4 . . . . . . . . . . . . . . . .7A

WACS 380 . . . . . . . . . . . . . .11A

X 8 . . . . . . . . . . . . . . . . . . . . .7B

X2CS-4T2 . . . . . . . . . . . . . . . .7A

X2SS-1T2 . . . . . . . . . . . . . . . .7A

WACS 388 . . . . . . . . . . . . . .11A

X 82 . . . . . . . . . . . . . . . . . . . .5E

X2CS-4T3 . . . . . . . . . . . . . . . .7A

X2SS-1T3 . . . . . . . . . . . . . . . .7A

WACS 420 . . . . . . . . . . . . . .11A

X 82 C . . . . . . . . . . . . . . . . . . .5E

X2CS-4T4 . . . . . . . . . . . . . . . .7A

X2SS-1T4 . . . . . . . . . . . . . . . .7A

WIF 101406 . . . . . . . . . . . . . .5B

X 82 N4 . . . . . . . . . . . . . . . . . .5E

X2FG-1 . . . . . . . . . . . . . . . . . .7A

X2SS-2 . . . . . . . . . . . . . . . . . .7A

367
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 368

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

X2SS-2B2 . . . . . . . . . . . . . . . .7A

XCBA H . . . . . . . . . . . . . . . . .8B

XCBB N4 110E63 . . . . . . . . . .8B

XCBC N4 225JN2 . . . . . . . . . .8B

X2SS-2B3 . . . . . . . . . . . . . . . .7A

XCBA N4 . . . . . . . . . . . . . . . .8B

XCBB N4 125E42 . . . . . . . . . .8B

XCBC N4 225JN3 . . . . . . . . . .8B

X2SS-2B4 . . . . . . . . . . . . . . . .7A

XCBA N4 15E22 . . . . . . . . . . .8B

XCBB N4 125E43 . . . . . . . . . .8B

XCBC N4 250JI2 . . . . . . . . . . .8B

X2SS-2F2 . . . . . . . . . . . . . . . .7A

XCBA N4 15E23 . . . . . . . . . . .8B

XCBB N4 125E62 . . . . . . . . . .8B

XCBC N4 250JI3 . . . . . . . . . . .8B

X2SS-2F3 . . . . . . . . . . . . . . . .7A

XCBA N4 15E42 . . . . . . . . . . .8B

XCBB N4 125E63 . . . . . . . . . .8B

XCBC N4 250JN2 . . . . . . . . . .8B

X2SS-2F4 . . . . . . . . . . . . . . . .7A

XCBA N4 15E43 . . . . . . . . . . .8B

XCBB N4 150E42 . . . . . . . . . .8B

XCBC N4 250JN3 . . . . . . . . . .8B

X2SS-2T2 . . . . . . . . . . . . . . . .7A

XCBA N4 15E62 . . . . . . . . . . .8B

XCBB N4 150E43 . . . . . . . . . .8B

XCBC N4 70JI2 . . . . . . . . . . . .8B

X2SS-2T3 . . . . . . . . . . . . . . . .7A

XCBA N4 15E63 . . . . . . . . . . .8B

XCBB N4 150E62 . . . . . . . . . .8B

XCBC N4 70JI3 . . . . . . . . . . . .8B

X2SS-2T4 . . . . . . . . . . . . . . . .7A

XCBA N4 20E22 . . . . . . . . . . .8B

XCBB N4 150E63 . . . . . . . . . .8B

XCBC N4 70JN2 . . . . . . . . . . .8B

X2SS-3 . . . . . . . . . . . . . . . . . .7A

XCBA N4 20E23 . . . . . . . . . . .8B

XCBB N4 80E22 . . . . . . . . . . .8B

XCBC N4 70JN3 . . . . . . . . . . .8B

X2SS-3B2 . . . . . . . . . . . . . . . .7A

XCBA N4 20E42 . . . . . . . . . . .8B

XCBB N4 80E23 . . . . . . . . . . .8B

XCBC N4 80JI2 . . . . . . . . . . . .8B

X2SS-3B3 . . . . . . . . . . . . . . . .7A

XCBA N4 20E43 . . . . . . . . . . .8B

XCBB N4 80E42 . . . . . . . . . . .8B

XCBC N4 80JI3 . . . . . . . . . . . .8B

X2SS-3B4 . . . . . . . . . . . . . . . .7A

XCBA N4 20E62 . . . . . . . . . . .8B

XCBB N4 80E43 . . . . . . . . . . .8B

XCBC N4 80JN2 . . . . . . . . . . .8B

X2SS-3F2 . . . . . . . . . . . . . . . .7A

XCBA N4 20E63 . . . . . . . . . . .8B

XCBB N4 80E62 . . . . . . . . . . .8B

XCBC N4 80JN3 . . . . . . . . . . .8B

X2SS-3F3 . . . . . . . . . . . . . . . .7A

XCBA N4 30DN3 . . . . . . . . . . .8B

XCBB N4 80E63 . . . . . . . . . . .8B

XCBC N4 90JI2 . . . . . . . . . . . .8B

X2SS-3F4 . . . . . . . . . . . . . . . .7A

XCBA N4 30E22 . . . . . . . . . . .8B

XCBB N4 90E22 . . . . . . . . . . .8B

XCBC N4 90JI3 . . . . . . . . . . . .8B

X2SS-3T2 . . . . . . . . . . . . . . . .7A

XCBA N4 30E23 . . . . . . . . . . .8B

XCBB N4 90E23 . . . . . . . . . . .8B

XCBC N4 90JN2 . . . . . . . . . . .8B

X2SS-3T3 . . . . . . . . . . . . . . . .7A

XCBA N4 30E42 . . . . . . . . . . .8B

XCBB N4 90E42 . . . . . . . . . . .8B

XCBC N4 90JN3 . . . . . . . . . . .8B

X2SS-3T4 . . . . . . . . . . . . . . . .7A

XCBA N4 30E43 . . . . . . . . . . .8B

XCBB N4 90E43 . . . . . . . . . . .8B

XCBD H . . . . . . . . . . . . . . . . .8B

X2SS-4 . . . . . . . . . . . . . . . . . .7A

XCBA N4 30E62 . . . . . . . . . . .8B

XCBB N4 90E62 . . . . . . . . . . .8B

XCBD N4 . . . . . . . . . . . . . . . .8B

X2SS-4B2 . . . . . . . . . . . . . . . .7A

XCBA N4 30E63 . . . . . . . . . . .8B

XCBB N4 90E63 . . . . . . . . . . .8B

XCBD N4 100KI2 . . . . . . . . . .8B

X2SS-4B3 . . . . . . . . . . . . . . . .7A

XCBA N4 40E22 . . . . . . . . . . .8B

XCBC H . . . . . . . . . . . . . . . . .8B

XCBD N4 100KI3 . . . . . . . . . .8B

X2SS-4B4 . . . . . . . . . . . . . . . .7A

XCBA N4 40E23 . . . . . . . . . . .8B

XCBC N4 . . . . . . . . . . . . . . . .8B

XCBD N4 100KN2 . . . . . . . . . .8B

X2SS-4F2 . . . . . . . . . . . . . . . .7A

XCBA N4 40E42 . . . . . . . . . . .8B

XCBC N4 100JI2 . . . . . . . . . . .8B

XCBD N4 100KN3 . . . . . . . . . .8B

X2SS-4F3 . . . . . . . . . . . . . . . .7A

XCBA N4 40E43 . . . . . . . . . . .8B

XCBC N4 100JI3 . . . . . . . . . . .8B

XCBD N4 125KI2 . . . . . . . . . .8B

X2SS-4F4 . . . . . . . . . . . . . . . .7A

XCBA N4 40E62 . . . . . . . . . . .8B

XCBC N4 100JN2 . . . . . . . . . .8B

XCBD N4 125KI3 . . . . . . . . . .8B

X2SS-4T2 . . . . . . . . . . . . . . . .7A

XCBA N4 40E63 . . . . . . . . . . .8B

XCBC N4 100JN3 . . . . . . . . . .8B

XCBD N4 125KN2 . . . . . . . . . .8B

X2SS-4T3 . . . . . . . . . . . . . . . .7A

XCBA N4 50E22 . . . . . . . . . . .8B

XCBC N4 110JI2 . . . . . . . . . . .8B

XCBD N4 125KN3 . . . . . . . . . .8B

X2SS-4T4 . . . . . . . . . . . . . . . .7A

XCBA N4 50E23 . . . . . . . . . . .8B

XCBC N4 110JI3 . . . . . . . . . . .8B

XCBD N4 150KI2 . . . . . . . . . .8B

XA 2 . . . . . . . . . . . . . . . . . . . .5E

XCBA N4 50E42 . . . . . . . . . . .8B

XCBC N4 110JN2 . . . . . . . . . .8B

XCBD N4 150KI3 . . . . . . . . . .8B

XA 3 . . . . . . . . . . . . . . . . . . . .5E

XCBA N4 50E43 . . . . . . . . . . .8B

XCBC N4 110JN3 . . . . . . . . . .8B

XCBD N4 150KN2 . . . . . . . . . .8B

XAF 24 . . . . . . . . . . . . . . . . .10A

XCBA N4 50E62 . . . . . . . . . . .8B

XCBC N4 125JI2 . . . . . . . . . . .8B

XCBD N4 150KN3 . . . . . . . . . .8B

XAF 6 . . . . . . . . . . . . . . . . . .10A

XCBA N4 50E63 . . . . . . . . . . .8B

XCBC N4 125JI3 . . . . . . . . . . .8B

XCBD N4 175KI2 . . . . . . . . . .8B

XAF 64 . . . . . . . . . . . . . . . . .10A

XCBA N4 60DN3 . . . . . . . . . . .8B

XCBC N4 125JN2 . . . . . . . . . .8B

XCBD N4 175KI3 . . . . . . . . . .8B

XB 1 . . . . . . . . . . . . . . . . . . . .5E

XCBA N4 60E22 . . . . . . . . . . .8B

XCBC N4 125JN3 . . . . . . . . . .8B

XCBD N4 175KN2 . . . . . . . . . .8B

XB 2 . . . . . . . . . . . . . . . . . . . .5E

XCBA N4 60E23 . . . . . . . . . . .8B

XCBC N4 150JI2 . . . . . . . . . . .8B

XCBD N4 175KN3 . . . . . . . . . .8B

XB 3 . . . . . . . . . . . . . . . . . . . .5E

XCBA N4 60E42 . . . . . . . . . . .8B

XCBC N4 150JI3 . . . . . . . . . . .8B

XCBD N4 200KI2 . . . . . . . . . .8B

XB 4 . . . . . . . . . . . . . . . . . . . .5E

XCBA N4 60E43 . . . . . . . . . . .8B

XCBC N4 150JN2 . . . . . . . . . .8B

XCBD N4 200KI3 . . . . . . . . . .8B

XBB . . . . . . . . . . . . . . . . . . . .9A

XCBA N4 60E62 . . . . . . . . . . .8B

XCBC N4 150JN3 . . . . . . . . . .8B

XCBD N4 200KN2 . . . . . . . . . .8B

XBCB 1 . . . . . . . . . . . . . . . . . .8A

XCBA N4 60E63 . . . . . . . . . . .8B

XCBC N4 175JI2 . . . . . . . . . . .8B

XCBD N4 200KN3 . . . . . . . . . .8B

XBCB 1 GF . . . . . . . . . . . . . . .8A

XCBA N4 70E22 . . . . . . . . . . .8B

XCBC N4 175JI3 . . . . . . . . . . .8B

XCBD N4 225KI2 . . . . . . . . . .8B

XBCB 2 . . . . . . . . . . . . . . . . . .8A

XCBA N4 70E23 . . . . . . . . . . .8B

XCBC N4 175JN2 . . . . . . . . . .8B

XCBD N4 225KI3 . . . . . . . . . .8B

XBCB 3 . . . . . . . . . . . . . . . . . .8A

XCBA N4 70E42 . . . . . . . . . . .8B

XCBC N4 175JN3 . . . . . . . . . .8B

XCBD N4 225KN2 . . . . . . . . . .8B

XBCC 1 SN . . . . . . . . . . . . . . .8A

XCBA N4 70E43 . . . . . . . . . . .8B

XCBC N4 200DN3 . . . . . . . . . .8B

XCBD N4 225KN3 . . . . . . . . . .8B

XBG . . . . . . . . . . . . . . . . . . . .9A

XCBA N4 70E62 . . . . . . . . . . .8B

XCBC N4 200JI2 . . . . . . . . . . .8B

XCBE H . . . . . . . . . . . . . . . . . .8B

XBPC . . . . . . . . . . . . . . . . . . .9A

XCBA N4 70E63 . . . . . . . . . . .8B

XCBC N4 200JI3 . . . . . . . . . . .8B

XCBE N4 . . . . . . . . . . . . . . . .8B

XBR . . . . . . . . . . . . . . . . . . . .9A

XCBB H . . . . . . . . . . . . . . . . .8B

XCBC N4 200JN2 . . . . . . . . . .8B

XCBE N4 250KI2 . . . . . . . . . . .8B

XBSB . . . . . . . . . . . . . . . . . . .9A

XCBB N4 . . . . . . . . . . . . . . . .8B

XCBC N4 200JN3 . . . . . . . . . .8B

XCBE N4 250KI3 . . . . . . . . . . .8B

XBSG . . . . . . . . . . . . . . . . . . .9A

XCBB N4 100DN3 . . . . . . . . . .8B

XCBC N4 225JI2 . . . . . . . . . . .8B

XCBE N4 250KN2 . . . . . . . . . .8B

XBSR . . . . . . . . . . . . . . . . . . .9A

XCBB N4 100E22 . . . . . . . . . .8B

XCBC N4 225JI3 . . . . . . . . . . .8B

XCBE N4 250KN3 . . . . . . . . . .8B

368
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 369

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

XCBE N4 250LI2 . . . . . . . . . . .8B

XCBSAQ N4 M6003 . . . . . . . .8C

XCE 061105 N4 . . . . . . . . . . .5A

XCE 162408 N4 . . . . . . . . . . .5A

XCBE N4 250LI3 . . . . . . . . . . .8B

XCBSAQ N4 M6007 . . . . . . . .8C

XCE 061204 N4 . . . . . . . . . . .5A

XCE 162410 N4 . . . . . . . . . . .5A

XCBE N4 300KI2 . . . . . . . . . . .8B

XCBSAQ N4 M6015 . . . . . . . .8C

XCE 061206 N4 . . . . . . . . . . .5A

XCE 162806 N4 . . . . . . . . . . .5A

XCBE N4 300KI3 . . . . . . . . . . .8B

XCBSAQ N4 M6130 . . . . . . . .8C

XCE 061305 N4 . . . . . . . . . . .5A

XCE 163406 N4 . . . . . . . . . . .5A

XCBE N4 300KN2 . . . . . . . . . .8B

XCBSBQ H . . . . . . . . . . . . . . .8C

XCE 071004 N4 . . . . . . . . . . .5A

XCE 163010 N4 . . . . . . . . . . .5A

XCBE N4 300KN3 . . . . . . . . . .8B

XCBSBQ N4 . . . . . . . . . . . . . .8C

XCE 071006 N4 . . . . . . . . . . .5A

XCE 164610 N4 . . . . . . . . . . .5A

XCBE N4 300LI2 . . . . . . . . . . .8B

XCBSBQ N4 22100 . . . . . . . . .8C

XCE 071805 N4 . . . . . . . . . . .5A

XCE 181804 N4 . . . . . . . . . . .5A

XCBE N4 300LI3 . . . . . . . . . . .8B

XCBSBQ N4 22100 . . . . . . . . .8C

XCE 080804 N4 . . . . . . . . . . .5A

XCE 181806 N4 . . . . . . . . . . .5A

XCBE N4 350KI2 . . . . . . . . . . .8B

XCBSBQ N4 2270 . . . . . . . . . .8C

XCE 080806 N4 . . . . . . . . . . .5A

XCE 181808 N4 . . . . . . . . . . .5A

XCBE N4 350KI3 . . . . . . . . . . .8B

XCBSBQ N4 2270 . . . . . . . . . .8C

XCE 080808 N4 . . . . . . . . . . .5A

XCE 182406 N4 . . . . . . . . . . .5A

XCBE N4 350KN2 . . . . . . . . . .8B

XCBSBQ N4 4270 . . . . . . . . . .8C

XCE 081004 N4 . . . . . . . . . . .5A

XCE 182408 N4 . . . . . . . . . . .5A

XCBE N4 350KN3 . . . . . . . . . .8B

XCBSBQ N4 4270 . . . . . . . . . .8C

XCE 081006 N4 . . . . . . . . . . .5A

XCE 182410 N4 . . . . . . . . . . .5A

XCBE N4 350LI2 . . . . . . . . . . .8B

XCBSBQ N4 6250 . . . . . . . . . .8C

XCE 081008 N4 . . . . . . . . . . .5A

XCE 183008 N4 . . . . . . . . . . .5A

XCBE N4 350LI3 . . . . . . . . . . .8B

XCBSBQ N4 6250 . . . . . . . . . .8C

XCE 081204 N4 . . . . . . . . . . .5A

XCE 183608 N4 . . . . . . . . . . .5A

XCBE N4 400KI2 . . . . . . . . . . .8B

XCBSBQ N4 M6250 . . . . . . . .8C

XCE 081206 N4 . . . . . . . . . . .5A

XCE 183610 N4 . . . . . . . . . . .5A

XCBE N4 400KI3 . . . . . . . . . . .8B

XCBSBQ N4 M6250 . . . . . . . .8C

XCE 081208 N4 . . . . . . . . . . .5A

XCE 203606 N4 . . . . . . . . . . .5A

XCBE N4 400KN2 . . . . . . . . . .8B

XCBSLQ H . . . . . . . . . . . . . . .8C

XCE 091105 N4 . . . . . . . . . . .5A

XCE 203612 N4 . . . . . . . . . . .5A

XCBE N4 400KN3 . . . . . . . . . .8B

XCBSLQ N4 . . . . . . . . . . . . . .8C

XCE 101004 N4 . . . . . . . . . . .5A

XCE 204806 N4 . . . . . . . . . . .5A

XCBE N4 400LI2 . . . . . . . . . . .8B

XCBSLQ N4 23100 . . . . . . . . .8C

XCE 101006 N4 . . . . . . . . . . .5A

XCE 204812 N4 . . . . . . . . . . .5A

XCBE N4 400LI3 . . . . . . . . . . .8B

XCBSLQ N4 23125 . . . . . . . . .8C

XCE 101008 N4 . . . . . . . . . . .5A

XCE 242408 N4 . . . . . . . . . . .5A

XCBF H . . . . . . . . . . . . . . . . . .8B

XCBSLQ N4 43100 . . . . . . . . .8C

XCE 101206 N4 . . . . . . . . . . .5A

XCE 242410 N4 . . . . . . . . . . .5A

XCBF N4 . . . . . . . . . . . . . . . .8B

XCBSLQ N4 4370 . . . . . . . . . .8C

XCE 101404 N4 . . . . . . . . . . .5A

XCE 243008 N4 . . . . . . . . . . .5A

XCBF N4 400MI2 . . . . . . . . . .8B

XCBSLQ N4 63100 . . . . . . . . .8C

XCE 101406 N4 . . . . . . . . . . .5A

XCE 243608 N4 . . . . . . . . . . .5A

XCBF N4 400MI3 . . . . . . . . . .8B

XCBSLQ N4 6370 . . . . . . . . . .8C

XCE 101408 N4 . . . . . . . . . . .5A

XCE 243610 N4 . . . . . . . . . . .5A

XCBF N4 500LI2 . . . . . . . . . . .8B

XCBSLQ N4 M63100 . . . . . . .8C

XCE 121204 N4 . . . . . . . . . . .5A

XCE 243612 N4 . . . . . . . . . . .5A

XCBF N4 500LI3 . . . . . . . . . . .8B

XCBSMQ H . . . . . . . . . . . . . . .8C

XCE 121206 N4 . . . . . . . . . . .5A

XCE 323612 N4 . . . . . . . . . . .5A

XCBF N4 500MI2 . . . . . . . . . .8B

XCBSMQ N4 . . . . . . . . . . . . .8C

XCE 121208 N4 . . . . . . . . . . .5A

XCE/XJF 041604 . . . . . . . . . . .5A

XCBF N4 500MI3 . . . . . . . . . .8B

XCBSMQ N4 24175 . . . . . . . .8C

XCE 121804 N4 . . . . . . . . . . .5A

XCE/XJF 060804 . . . . . . . . . . .5A

XCBF N4 600LI2 . . . . . . . . . . .8B

XCBSMQ N4 24200 . . . . . . . .8C

XCE 121806 N4 . . . . . . . . . . .5A

XCE/XJF 060805 . . . . . . . . . . .5A

XCBF N4 600LI3 . . . . . . . . . . .8B

XCBSMQ N4 44175 . . . . . . . .8C

XCE 121808 N4 . . . . . . . . . . .5A

XCE/XJF 060806 . . . . . . . . . . .5A

XCBF N4 600MI2 . . . . . . . . . .8B

XCBSMQ N4 44200 . . . . . . . .8C

XCE 122005 N4 . . . . . . . . . . .5A

XCE/XJF 061105 . . . . . . . . . . .5A

XCBF N4 600MI3 . . . . . . . . . .8B

XCBSMQ N4 64125 . . . . . . . .8C

XCE 122404 N4 . . . . . . . . . . .5A

XCE/XJF 061204 . . . . . . . . . . .5A

XCBF N4 700MI2 . . . . . . . . . .8B

XCBSMQ N4 64150 . . . . . . . .8C

XCE 122406 N4 . . . . . . . . . . .5A

XCE/XJF 061206 . . . . . . . . . . .5A

XCBF N4 700MI3 . . . . . . . . . .8B

XCBSMQ N4 64175 . . . . . . . .8C

XCE 122408 N4 . . . . . . . . . . .5A

XCE/XJF 061305 . . . . . . . . . . .5A

XCBF N4 800MI2 . . . . . . . . . .8B

XCBSN H . . . . . . . . . . . . . . . .8C

XCE 122410 N4 . . . . . . . . . . .5A

XCE/XJF 071004 . . . . . . . . . . .5A

XCBF N4 800MI3 . . . . . . . . . .8B

XCBSN N4 . . . . . . . . . . . . . . .8C

XCE 123006 N4 . . . . . . . . . . .5A

XCE/XJF 071006 . . . . . . . . . . .5A

XCBG H . . . . . . . . . . . . . . . . .8B

XCBSN N4 25225 . . . . . . . . . .8C

XCE 123604 N4 . . . . . . . . . . .5A

XCE/XJF 071805 . . . . . . . . . . .5A

XCBG N4 . . . . . . . . . . . . . . . .8B

XCBSN N4 25300 . . . . . . . . . .8C

XCE 123606 N4 . . . . . . . . . . .5A

XCE/XJF 080804 . . . . . . . . . . .5A

XCBH 1 GF . . . . . . . . . . . . . . .8A

XCBSN N4 25400 . . . . . . . . . .8C

XCE 123608 N4 . . . . . . . . . . .5A

XCE/XJF 080806 . . . . . . . . . . .5A

XCBSAQ H . . . . . . . . . . . . . . .8C

XCBSN N4 45225 . . . . . . . . . .8C

XCE 124608 N4 . . . . . . . . . . .5A

XCE/XJF 080808 . . . . . . . . . . .5A

XCBSAQ N4 2015 . . . . . . . . . .8C

XCBSN N4 45300 . . . . . . . . . .8C

XCE 141404 N4 . . . . . . . . . . .5A

XCE/XJF 081004 . . . . . . . . . . .5A

XCBSAQ N4 2020 . . . . . . . . . .8C

XCBSN N4 45400 . . . . . . . . . .8C

XCE 141406 N4 . . . . . . . . . . .5A

XCE/XJF 081006 . . . . . . . . . . .5A

XCBSAQ N4 2130 . . . . . . . . . .8C

XCBSN N4 65200 . . . . . . . . . .8C

XCE 141408 N4 . . . . . . . . . . .5A

XCE/XJF 081008 . . . . . . . . . . .5A

XCBSAQ N4 2150 . . . . . . . . . .8C

XCBSN N4 65225 . . . . . . . . . .8C

XCE 142210 N4 . . . . . . . . . . .5A

XCE/XJF 081204 . . . . . . . . . . .5A

XCBSAQ N4 4015 . . . . . . . . . .8C

XCBSN N4 65400 . . . . . . . . . .8C

XCE 142213 N4 . . . . . . . . . . .5A

XCE/XJF 081206 . . . . . . . . . . .5A

XCBSAQ N4 4020 . . . . . . . . . .8C

XCBSN N4 M65400 . . . . . . . .8C

XCE 142806 N4 . . . . . . . . . . .5A

XCE/XJF 081208 . . . . . . . . . . .5A

XCBSAQ N4 4130 . . . . . . . . . .8C

XCE 041604 N4 . . . . . . . . . . .5A

XCE 161604 N4 . . . . . . . . . . .5A

XCE/XJF 091105 . . . . . . . . . . .5A

XCBSAQ N4 6015 . . . . . . . . . .8C

XCE 060804 N4 . . . . . . . . . . .5A

XCE 161606 N4 . . . . . . . . . . .5A

XCE/XJF 101004 . . . . . . . . . . .5A

XCBSAQ N4 6020 . . . . . . . . . .8C

XCE 060805 N4 . . . . . . . . . . .5A

XCE 161608 N4 . . . . . . . . . . .5A

XCE/XJF 101006 . . . . . . . . . . .5A

XCBSAQ N4 6130 . . . . . . . . . .8C

XCE 060806 N4 . . . . . . . . . . .5A

XCE 162406 N4 . . . . . . . . . . .5A

XCE/XJF 101008 . . . . . . . . . . .5A

369
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 370

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

XCE/XJF 101404 . . . . . . . . . . .5A

XCE/XJF 323612 . . . . . . . . . . .5A

XCEX 142806 . . . . . . . . . . . . .5A

XCIAD12 . . . . . . . . . . . . . . . . .8D

XCE/XJF 101406 . . . . . . . . . . .5A

XCEX 041604 . . . . . . . . . . . . .5A

XCEX 161604 . . . . . . . . . . . . .5A

XCIAD18 . . . . . . . . . . . . . . . . .8D

XCE/XJF 101408 . . . . . . . . . . .5A

XCEX 060804 . . . . . . . . . . . . .5A

XCEX 161606 . . . . . . . . . . . . .5A

XCIAD25 . . . . . . . . . . . . . . . . .8D

XCE/XJF 101410 . . . . . . . . . . .5A

XCEX 060805 . . . . . . . . . . . . .5A

XCEX 161608 . . . . . . . . . . . . .5A

XCIAD32 . . . . . . . . . . . . . . . . .8D

XCE/XJF 121204 . . . . . . . . . . .5A

XCEX 060806 . . . . . . . . . . . . .5A

XCEX 162406 . . . . . . . . . . . . .5A

XCIAD37 . . . . . . . . . . . . . . . . .8D

XCE/XJF 121206 . . . . . . . . . . .5A

XCEX 061105 . . . . . . . . . . . . .5A

XCEX 162408 . . . . . . . . . . . . .5A

XCIAD40 . . . . . . . . . . . . . . . . .8D

XCE/XJF 121208 . . . . . . . . . . .5A

XCEX 061204 . . . . . . . . . . . . .5A

XCEX 162410 . . . . . . . . . . . . .5A

XCIAD50 . . . . . . . . . . . . . . . . .8D

XCE/XJF 121804 . . . . . . . . . . .5A

XCEX 061206 . . . . . . . . . . . . .5A

XCEX 162806 . . . . . . . . . . . . .5A

XCIAD65 . . . . . . . . . . . . . . . . .8D

XCE/XJF 121806 . . . . . . . . . . .5A

XCEX 061305 . . . . . . . . . . . . .5A

XCEX 163010 . . . . . . . . . . . . .5A

XCIAD9 . . . . . . . . . . . . . . . . . .8D

XCE/XJF 121808 . . . . . . . . . . .5A

XCEX 071004 . . . . . . . . . . . . .5A

XCEX 163406 . . . . . . . . . . . . .5A

XCIAH10 . . . . . . . . . . . . . . . . .8D

XCE/XJF 122005 . . . . . . . . . . .5A

XCEX 071006 . . . . . . . . . . . . .5A

XCEX 164610 . . . . . . . . . . . . .5A

XCIAH12 . . . . . . . . . . . . . . . . .8D

XCE/XJF 122404 . . . . . . . . . . .5A

XCEX 071805 . . . . . . . . . . . . .5A

XCEX 181804 . . . . . . . . . . . . .5A

XCIAH18 . . . . . . . . . . . . . . . . .8D

XCE/XJF 122406 . . . . . . . . . . .5A

XCEX 080804 . . . . . . . . . . . . .5A

XCEX 181806 . . . . . . . . . . . . .5A

XCIAH25 . . . . . . . . . . . . . . . . .8D

XCE/XJF 122408 . . . . . . . . . . .5A

XCEX 080806 . . . . . . . . . . . . .5A

XCEX 181808 . . . . . . . . . . . . .5A

XCIAH32 . . . . . . . . . . . . . . . . .8D

XCE/XJF 122410 . . . . . . . . . . .5A

XCEX 080808 . . . . . . . . . . . . .5A

XCEX 182406 . . . . . . . . . . . . .5A

XCIAH37 . . . . . . . . . . . . . . . . .8D

XCE/XJF 123006 . . . . . . . . . . .5A

XCEX 081004 . . . . . . . . . . . . .5A

XCEX 182408 . . . . . . . . . . . . .5A

XCIAH44 . . . . . . . . . . . . . . . . .8D

XCE/XJF 123604 . . . . . . . . . . .5A

XCEX 081006 . . . . . . . . . . . . .5A

XCEX 182410 . . . . . . . . . . . . .5A

XCIAH60 . . . . . . . . . . . . . . . . .8D

XCE/XJF 123606 . . . . . . . . . . .5A

XCEX 081008 . . . . . . . . . . . . .5A

XCEX 183008 . . . . . . . . . . . . .5A

XCIAH73 . . . . . . . . . . . . . . . . .8D

XCE/XJF 123608 . . . . . . . . . . .5A

XCEX 081204 . . . . . . . . . . . . .5A

XCEX 183608 . . . . . . . . . . . . .5A

XCIAS12 . . . . . . . . . . . . . . . . .8D

XCE/XJF 124608 . . . . . . . . . . .5A

XCEX 081206 . . . . . . . . . . . . .5A

XCEX 183610 . . . . . . . . . . . . .5A

XCIAS17 . . . . . . . . . . . . . . . . .8D

XCE/XJF 141404 . . . . . . . . . . .5A

XCEX 081208 . . . . . . . . . . . . .5A

XCEX 203606 . . . . . . . . . . . . .5A

XCIAS25 . . . . . . . . . . . . . . . . .8D

XCE/XJF 141406 . . . . . . . . . . .5A

XCEX 091105 . . . . . . . . . . . . .5A

XCEX 203612 . . . . . . . . . . . . .5A

XCIAS28 . . . . . . . . . . . . . . . . .8D

XCE/XJF 141408 . . . . . . . . . . .5A

XCEX 101004 . . . . . . . . . . . . .5A

XCEX 204806 . . . . . . . . . . . . .5A

XCIAS32 . . . . . . . . . . . . . . . . .8D

XCE/XJF 142210 . . . . . . . . . . .5A

XCEX 101006 . . . . . . . . . . . . .5A

XCEX 242408 . . . . . . . . . . . . .5A

XCIAS40 . . . . . . . . . . . . . . . . .8D

XCE/XJF 142213 . . . . . . . . . . .5A

XCEX 101008 . . . . . . . . . . . . .5A

XCEX 242410 . . . . . . . . . . . . .5A

XCIAS50 . . . . . . . . . . . . . . . . .8D

XCE/XJF 142806 . . . . . . . . . . .5A

XCEX 101404 . . . . . . . . . . . . .5A

XCEX 243008 . . . . . . . . . . . . .5A

XCIAS9 . . . . . . . . . . . . . . . . . .8D

XCE/XJF 161604 . . . . . . . . . . .5A

XCEX 101406 . . . . . . . . . . . . .5A

XCEX 243608 . . . . . . . . . . . . .5A

XCIBB110 . . . . . . . . . . . . . . . .8D

XCE/XJF 161606 . . . . . . . . . . .5A

XCEX 101408 . . . . . . . . . . . . .5A

XCEX 243610 . . . . . . . . . . . . .5A

XCIBB80 . . . . . . . . . . . . . . . . .8D

XCE/XJF 161608 . . . . . . . . . . .5A

XCEX 101410 . . . . . . . . . . . . .5A

XCEX 243612 . . . . . . . . . . . . .5A

XCIBD80 . . . . . . . . . . . . . . . . .8D

XCE/XJF 162406 . . . . . . . . . . .5A

XCEX 121204 . . . . . . . . . . . . .5A

XCEX 323612 . . . . . . . . . . . . .5A

XCIBS65 . . . . . . . . . . . . . . . . .8D

XCE/XJF 162408 . . . . . . . . . . .5A

XCEX 121206 . . . . . . . . . . . . .5A

XCF 1 . . . . . . . . . . . . . . . . . . .9A

XCIBS80 . . . . . . . . . . . . . . . . .8D

XCE/XJF 162410 . . . . . . . . . . .5A

XCEX 121208 . . . . . . . . . . . . .5A

XCF 1 N4 . . . . . . . . . . . . . . . .9A

XCIBS95 . . . . . . . . . . . . . . . . .8D

XCE/XJF 163010 . . . . . . . . . . .5A

XCEX 121804 . . . . . . . . . . . . .5A

XCF 2 . . . . . . . . . . . . . . . . . . .9A

XCMRSG H . . . . . . . . . . . . . . .8C

XCE/XJF 164610 . . . . . . . . . . .5A

XCEX 121806 . . . . . . . . . . . . .5A

XCF 2 N4 . . . . . . . . . . . . . . . .9A

XCMRSG N4 . . . . . . . . . . . . .8C

XCE/XJF 181804 . . . . . . . . . . .5A

XCEX 121808 . . . . . . . . . . . . .5A

XCF 3 . . . . . . . . . . . . . . . . . . .9A

XCMRSG N4 2015 . . . . . . . . .8C

XCE/XJF 181806 . . . . . . . . . . .5A

XCEX 122005 . . . . . . . . . . . . .5A

XCF 3 N4 . . . . . . . . . . . . . . . .9A

XCMRSG N4 2020 . . . . . . . . .8C

XCE/XJF 181808 . . . . . . . . . . .5A

XCEX 122404 . . . . . . . . . . . . .5A

XCF 4 . . . . . . . . . . . . . . . . . . .9A

XCMRSG N4 2130 . . . . . . . . .8C

XCE/XJF 182406 . . . . . . . . . . .5A

XCEX 122406 . . . . . . . . . . . . .5A

XCF 4 N4 . . . . . . . . . . . . . . . .9A

XCMRSG N4 2150 . . . . . . . . .8C

XCE/XJF 182408 . . . . . . . . . . .5A

XCEX 122408 . . . . . . . . . . . . .5A

XCF 5 . . . . . . . . . . . . . . . . . . .9A

XCMRSG N4 4015 . . . . . . . . .8C

XCE/XJF 182410 . . . . . . . . . . .5A

XCEX 122410 . . . . . . . . . . . . .5A

XCF 5 N4 . . . . . . . . . . . . . . . .9A

XCMRSG N4 4020 . . . . . . . . .8C

XCE/XJF 183008 . . . . . . . . . . .5A

XCEX 123006 . . . . . . . . . . . . .5A

XCFT . . . . . . . . . . . . . . . . . . . .9A

XCMRSG N4 4130 . . . . . . . . .8C

XCE/XJF 183608 . . . . . . . . . . .5A

XCEX 123604 . . . . . . . . . . . . .5A

XCIAA11 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 6015 . . . . . . . . .8C

XCE/XJF 183610 . . . . . . . . . . .5A

XCEX 123606 . . . . . . . . . . . . .5A

XCIAA17 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 6020 . . . . . . . . .8C

XCE/XJF 203612 . . . . . . . . . . .5A

XCEX 123608 . . . . . . . . . . . . .5A

XCIAA25 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 6130 . . . . . . . . .8C

XCE/XJF 204812 . . . . . . . . . . .5A

XCEX 124608 . . . . . . . . . . . . .5A

XCIAA28 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 M6003 . . . . . . . .8C

XCE/XJF 242408 . . . . . . . . . . .5A

XCEX 141404 . . . . . . . . . . . . .5A

XCIAA32 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 M6007 . . . . . . . .8C

XCE/XJF 242410 . . . . . . . . . . .5A

XCEX 141406 . . . . . . . . . . . . .5A

XCIAA41 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 M6015 . . . . . . . .8C

XCE/XJF 243008 . . . . . . . . . . .5A

XCEX 141408 . . . . . . . . . . . . .5A

XCIAA54 . . . . . . . . . . . . . . . . .8D

XCMRSG N4 M6130 . . . . . . . .8C

XCE/XJF 243608 . . . . . . . . . . .5A

XCEX 142210 . . . . . . . . . . . . .5A

XCIAA65 . . . . . . . . . . . . . . . . .8D

XCMRSK H . . . . . . . . . . . . . . .8C

XCE/XJF 243612 . . . . . . . . . . .5A

XCEX 142213 . . . . . . . . . . . . .5A

XCIAA9 . . . . . . . . . . . . . . . . . .8D

XCMRSK N4

. . . . . . . . . . . . .8C

370
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 371

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

XCMRSK N4 22100 . . . . . . . . .8C

XDHLDGCX-6T . . . . . . . . . . . .4A

XFC 24 . . . . . . . . . . . . . . . . .10A

XFCU 221 . . . . . . . . . . . . . . .10A

XCMRSK N4 2270 . . . . . . . . .8C

XDHLDGCX-8T . . . . . . . . . . . .4A

XFC 26 . . . . . . . . . . . . . . . . .10A

XFCU 224 . . . . . . . . . . . . . . .10A

XCMRSK N4 4270 . . . . . . . . .8C

XDHLFCX . . . . . . . . . . . . . . . .4A

XFC 28 . . . . . . . . . . . . . . . . .10A

XFCU 227 . . . . . . . . . . . . . . .10A

XCMRSK N4 6270 . . . . . . . . .8C

XDHLFCX-10T . . . . . . . . . . . . .4A

XFC 310 . . . . . . . . . . . . . . . .10A

XFCU 230 . . . . . . . . . . . . . . .10A

XCMRSK N4 M6250 . . . . . . . .8C

XDHLFCX-12T . . . . . . . . . . . . .4A

XFC 312 . . . . . . . . . . . . . . . .10A

XFCU 233 . . . . . . . . . . . . . . .10A

XCMRSP H . . . . . . . . . . . . . . .8C

XDHLFCX-2T . . . . . . . . . . . . . .4A

XFC 315 . . . . . . . . . . . . . . . .10A

XFCU 236 . . . . . . . . . . . . . . .10A

XCMRSP N4

. . . . . . . . . . . . .8C

XDHLFCX-4T . . . . . . . . . . . . . .4A

XFC 318 . . . . . . . . . . . . . . . .10A

XFCU 24 . . . . . . . . . . . . . . . .10A

XCMRSP N4 23100 . . . . . . . . .8C

XDHLFCX-6T . . . . . . . . . . . . . .4A

XFC 321 . . . . . . . . . . . . . . . .10A

XFCU 26 . . . . . . . . . . . . . . . .10A

XCMRSP N4 23125 . . . . . . . . .8C

XDHLFCX-8T . . . . . . . . . . . . . .4A

XFC 324 . . . . . . . . . . . . . . . .10A

XFCU 28 . . . . . . . . . . . . . . . .10A

XCMRSP N4 43100 . . . . . . . . .8C

XDHLFGCX . . . . . . . . . . . . . . .4A

XFC 327 . . . . . . . . . . . . . . . .10A

XFCU 310 . . . . . . . . . . . . . . .10A

XCMRSP N4 43125 . . . . . . . . .8C

XDHLFGCX-10T . . . . . . . . . . .4A

XFC 330 . . . . . . . . . . . . . . . .10A

XFCU 312 . . . . . . . . . . . . . . .10A

XCMRSP N4 63100 . . . . . . . . .8C

XDHLFGCX-12T . . . . . . . . . . .4A

XFC 333 . . . . . . . . . . . . . . . .10A

XFCU 315 . . . . . . . . . . . . . . .10A

XCMRSP N4 M63100 . . . . . . .8C

XDHLFGCX-2T . . . . . . . . . . . .4A

XFC 336 . . . . . . . . . . . . . . . .10A

XFCU 318 . . . . . . . . . . . . . . .10A

XCMRSP N4 M64150 . . . . . . .8C

XDHLFGCX-4T . . . . . . . . . . . .4A

XFC 34 . . . . . . . . . . . . . . . . .10A

XFCU 321 . . . . . . . . . . . . . . .10A

XCS 1 . . . . . . . . . . . . . . . . . . .9A

XDHLFGCX-6T . . . . . . . . . . . .4A

XFC 36 . . . . . . . . . . . . . . . . .10A

XFCU 324 . . . . . . . . . . . . . . .10A

XCS 2 . . . . . . . . . . . . . . . . . . .9A

XDHLFGCX-8T . . . . . . . . . . . .4A

XFC 38 . . . . . . . . . . . . . . . . .10A

XFCU 327 . . . . . . . . . . . . . . .10A

XCS 2H . . . . . . . . . . . . . . . . . .9A

XDHMDCX . . . . . . . . . . . . . . .4A

XFC 410 . . . . . . . . . . . . . . . .10A

XFCU 330 . . . . . . . . . . . . . . .10A

XCS 3 . . . . . . . . . . . . . . . . . . .9A

XDHMDCX-2T . . . . . . . . . . . . .4A

XFC 412 . . . . . . . . . . . . . . . .10A

XFCU 333 . . . . . . . . . . . . . . .10A

XCS 4 . . . . . . . . . . . . . . . . . . .9A

XDHMDCX-4T . . . . . . . . . . . . .4A

XFC 415 . . . . . . . . . . . . . . . .10A

XFCU 336 . . . . . . . . . . . . . . .10A

XCS 5 . . . . . . . . . . . . . . . . . . .9A

XDHMDCX-6T . . . . . . . . . . . . .4A

XFC 418 . . . . . . . . . . . . . . . .10A

XFCU 34 . . . . . . . . . . . . . . . .10A

XCWL-GH . . . . . . . . . . . . . . . .9A

XDHMDCX-8T . . . . . . . . . . . . .4A

XFC 421 . . . . . . . . . . . . . . . .10A

XFCU 36 . . . . . . . . . . . . . . . .10A

XCWL-GH . . . . . . . . . . . . . . . .9A

XDHMDGCX . . . . . . . . . . . . . .4A

XFC 424 . . . . . . . . . . . . . . . .10A

XFCU 38 . . . . . . . . . . . . . . . .10A

XDB 2 . . . . . . . . . . . . . . . . . .10A

XDHMDGCX-2T . . . . . . . . . . .4A

XFC 427 . . . . . . . . . . . . . . . .10A

XFCU 410 . . . . . . . . . . . . . . .10A

XDBH 2 . . . . . . . . . . . . . . . . .10A

XDHMDGCX-4T . . . . . . . . . . .4A

XFC 430 . . . . . . . . . . . . . . . .10A

XFCU 412 . . . . . . . . . . . . . . .10A

XDC . . . . . . . . . . . . . . . . . . .10A

XDHMDGCX-6T . . . . . . . . . . .4A

XFC 433 . . . . . . . . . . . . . . . .10A

XFCU 415 . . . . . . . . . . . . . . .10A

XDF . . . . . . . . . . . . . . . . . . . .4B

XDHMDGCX-8T . . . . . . . . . . .4A

XFC 436 . . . . . . . . . . . . . . . .10A

XFCU 418 . . . . . . . . . . . . . . .10A

XDHDCX . . . . . . . . . . . . . . . . .4A

XDHMFCX . . . . . . . . . . . . . . .4A

XFC 46 . . . . . . . . . . . . . . . . .10A

XFCU 421 . . . . . . . . . . . . . . .10A

XDHDCX-2T . . . . . . . . . . . . . .4A

XDHMFCX-2T . . . . . . . . . . . . .4A

XFC 48 . . . . . . . . . . . . . . . . .10A

XFCU 424 . . . . . . . . . . . . . . .10A

XDHDCX-4T . . . . . . . . . . . . . .4A

XDHMFCX-4T . . . . . . . . . . . . .4A

XFC 512 . . . . . . . . . . . . . . . .10A

XFCU 427 . . . . . . . . . . . . . . .10A

XDHDGCX . . . . . . . . . . . . . . .4A

XDHMFCX-6T . . . . . . . . . . . . .4A

XFC 515 . . . . . . . . . . . . . . . .10A

XFCU 430 . . . . . . . . . . . . . . .10A

XDHDGCX-2T . . . . . . . . . . . . .4A

XDHMFCX-8T . . . . . . . . . . . . .4A

XFC 518 . . . . . . . . . . . . . . . .10A

XFCU 433 . . . . . . . . . . . . . . .10A

XDHDGCX-4T . . . . . . . . . . . . .4A

XDHMFGCX . . . . . . . . . . . . . .4A

XFC 521 . . . . . . . . . . . . . . . .10A

XFCU 436 . . . . . . . . . . . . . . .10A

XDHFCX . . . . . . . . . . . . . . . . .4A

XDHMFGCX-2T . . . . . . . . . . . .4A

XFC 524 . . . . . . . . . . . . . . . .10A

XFCU 46 . . . . . . . . . . . . . . . .10A

XDHFCX-2T . . . . . . . . . . . . . . .4A

XDHMFGCX-4T . . . . . . . . . . . .4A

XFC 527 . . . . . . . . . . . . . . . .10A

XFCU 48 . . . . . . . . . . . . . . . .10A

XDHFCX-4T . . . . . . . . . . . . . . .4A

XDHMFGCX-6T . . . . . . . . . . . .4A

XFC 530 . . . . . . . . . . . . . . . .10A

XFSA2A1 . . . . . . . . . . . . . . . .7C

XDHFGCX . . . . . . . . . . . . . . . .4A

XDHMFGCX-8T . . . . . . . . . . . .4A

XFC 533 . . . . . . . . . . . . . . . .10A

XFSA2A2 . . . . . . . . . . . . . . . .7C

XDHFGCX-2T . . . . . . . . . . . . .4A

XDIAA17 . . . . . . . . . . . . . . . . .8D

XFC 536 . . . . . . . . . . . . . . . .10A

XFSA2A3 . . . . . . . . . . . . . . . .7C

XDHFGCX-4T . . . . . . . . . . . . .4A

XFA2 . . . . . . . . . . . . . . . . . . .10A

XFC 612 . . . . . . . . . . . . . . . .10A

XFSA2A4 . . . . . . . . . . . . . . . .7C

XDHLDCX . . . . . . . . . . . . . . . .4A

XFA-2 . . . . . . . . . . . . . . . . . .10A

XFC 615 . . . . . . . . . . . . . . . .10A

XFSA2A5 . . . . . . . . . . . . . . . .7C

XDHLDCX-10T . . . . . . . . . . . .4A

XFAX2 . . . . . . . . . . . . . . . . . .10A

XFC 618 . . . . . . . . . . . . . . . .10A

XFSA2AB1 . . . . . . . . . . . . . . .7C

XDHLDCX-12T . . . . . . . . . . . .4A

XFC 210 . . . . . . . . . . . . . . . .10A

XFC 621 . . . . . . . . . . . . . . . .10A

XFSA2AB2 . . . . . . . . . . . . . . .7C

XDHLDCX-2T . . . . . . . . . . . . .4A

XFC 212 . . . . . . . . . . . . . . . .10A

XFC 624 . . . . . . . . . . . . . . . .10A

XFSA2AB3 . . . . . . . . . . . . . . .7C

XDHLDCX-4T . . . . . . . . . . . . .4A

XFC 215 . . . . . . . . . . . . . . . .10A

XFC 627 . . . . . . . . . . . . . . . .10A

XFSA2AB4 . . . . . . . . . . . . . . .7C

XDHLDCX-6T . . . . . . . . . . . . .4A

XFC 218 . . . . . . . . . . . . . . . .10A

XFC 630 . . . . . . . . . . . . . . . .10A

XFSA2AB5 . . . . . . . . . . . . . . .7C

XDHLDCX-8T . . . . . . . . . . . . .4A

XFC 221 . . . . . . . . . . . . . . . .10A

XFC 633 . . . . . . . . . . . . . . . .10A

XFSA2ABC1 . . . . . . . . . . . . . .7C

XDHLDGCX . . . . . . . . . . . . . .4A

XFC 224 . . . . . . . . . . . . . . . .10A

XFC 636 . . . . . . . . . . . . . . . .10A

XFSA2ABC2 . . . . . . . . . . . . . .7C

XDHLDGCX-10T . . . . . . . . . . .4A

XFC 227 . . . . . . . . . . . . . . . .10A

XFCU 210 . . . . . . . . . . . . . . .10A

XFSA2ABC3 . . . . . . . . . . . . . .7C

XDHLDGCX-12T . . . . . . . . . . .4A

XFC 230 . . . . . . . . . . . . . . . .10A

XFCU 212 . . . . . . . . . . . . . . .10A

XFSA2ABC4 . . . . . . . . . . . . . .7C

XDHLDGCX-2T . . . . . . . . . . . .4A

XFC 233 . . . . . . . . . . . . . . . .10A

XFCU 215 . . . . . . . . . . . . . . .10A

XFSA2ABC5 . . . . . . . . . . . . . .7C

XDHLDGCX-4T . . . . . . . . . . . .4A

XFC 236 . . . . . . . . . . . . . . . .10A

XFCU 218 . . . . . . . . . . . . . . .10A

XFSA2ABCD1 . . . . . . . . . . . . .7C

371
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 372

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

XFSA2ABCD2 . . . . . . . . . . . . .7C

XFSA2BD2 . . . . . . . . . . . . . . .7C

XFSA3ACD1 . . . . . . . . . . . . . .7C

XFSA4ABC3 . . . . . . . . . . . . . .7C

XFSA2ABCD3 . . . . . . . . . . . . .7C

XFSA2BD3 . . . . . . . . . . . . . . .7C

XFSA3ACD2 . . . . . . . . . . . . . .7C

XFSA4ABC4 . . . . . . . . . . . . . .7C

XFSA2ABCD4 . . . . . . . . . . . . .7C

XFSA2BD4 . . . . . . . . . . . . . . .7C

XFSA3ACD3 . . . . . . . . . . . . . .7C

XFSA4ABC5 . . . . . . . . . . . . . .7C

XFSA2ABCD5 . . . . . . . . . . . . .7C

XFSA2BD5 . . . . . . . . . . . . . . .7C

XFSA3ACD4 . . . . . . . . . . . . . .7C

XFSA4ABCD1 . . . . . . . . . . . . .7C

XFSA2ABCDRA . . . . . . . . . . .7C

XFSA2BDRA . . . . . . . . . . . . . .7C

XFSA3ACD5 . . . . . . . . . . . . . .7C

XFSA4ABCD2 . . . . . . . . . . . . .7C

XFSA2ABCRA . . . . . . . . . . . . .7C

XFSA2BRA . . . . . . . . . . . . . . .7C

XFSA3ACDRA . . . . . . . . . . . . .7C

XFSA4ABCD3 . . . . . . . . . . . . .7C

XFSA2ABD1 . . . . . . . . . . . . . .7C

XFSA30925 . . . . . . . . . . . . . . .7C

XFSA3ACRA . . . . . . . . . . . . . .7C

XFSA4ABCD4 . . . . . . . . . . . . .7C

XFSA2ABD2 . . . . . . . . . . . . . .7C

XFSA3101 . . . . . . . . . . . . . . . .7C

XFSA3AD1 . . . . . . . . . . . . . . .7C

XFSA4ABCD5 . . . . . . . . . . . . .7C

XFSA2ABD3 . . . . . . . . . . . . . .7C

XFSA31208 . . . . . . . . . . . . . . .7C

XFSA3AD2 . . . . . . . . . . . . . . .7C

XFSA4ABCDRA . . . . . . . . . . .7C

XFSA2ABD4 . . . . . . . . . . . . . .7C

XFSA31209 . . . . . . . . . . . . . . .7C

XFSA3AD3 . . . . . . . . . . . . . . .7C

XFSA4ABCRA . . . . . . . . . . . . .7C

XFSA2ABD5 . . . . . . . . . . . . . .7C

XFSA3173 . . . . . . . . . . . . . . . .7C

XFSA3AD4 . . . . . . . . . . . . . . .7C

XFSA4ABD1 . . . . . . . . . . . . . .7C

XFSA2ABDRA . . . . . . . . . . . . .7C

XFSA3178 . . . . . . . . . . . . . . . .7C

XFSA3AD5 . . . . . . . . . . . . . . .7C

XFSA4ABD2 . . . . . . . . . . . . . .7C

XFSA2ABRA . . . . . . . . . . . . . .7C

XFSA3185 . . . . . . . . . . . . . . . .7C

XFSA3ADRA . . . . . . . . . . . . . .7C

XFSA4ABD3 . . . . . . . . . . . . . .7C

XFSA2AC1 . . . . . . . . . . . . . . .7C

XFSA32089 . . . . . . . . . . . . . . .7C

XFSA3ARA . . . . . . . . . . . . . . .7C

XFSA4ABD4 . . . . . . . . . . . . . .7C

XFSA2AC2 . . . . . . . . . . . . . . .7C

XFSA3223 . . . . . . . . . . . . . . . .7C

XFSA3B1 . . . . . . . . . . . . . . . .7C

XFSA4ABD5 . . . . . . . . . . . . . .7C

XFSA2AC3 . . . . . . . . . . . . . . .7C

XFSA3911 . . . . . . . . . . . . . . . .7C

XFSA3B2 . . . . . . . . . . . . . . . .7C

XFSA4ABDRA . . . . . . . . . . . . .7C

XFSA2AC4 . . . . . . . . . . . . . . .7C

XFSA3A1 . . . . . . . . . . . . . . . .7C

XFSA3B3 . . . . . . . . . . . . . . . .7C

XFSA4ABRA . . . . . . . . . . . . . .7C

XFSA2AC5 . . . . . . . . . . . . . . .7C

XFSA3A2 . . . . . . . . . . . . . . . .7C

XFSA3B4 . . . . . . . . . . . . . . . .7C

XFSA4AC1 . . . . . . . . . . . . . . .7C

XFSA2ACD1 . . . . . . . . . . . . . .7C

XFSA3A3 . . . . . . . . . . . . . . . .7C

XFSA3B5 . . . . . . . . . . . . . . . .7C

XFSA4AC2 . . . . . . . . . . . . . . .7C

XFSA2ACD2 . . . . . . . . . . . . . .7C

XFSA3A4 . . . . . . . . . . . . . . . .7C

XFSA3BC1 . . . . . . . . . . . . . . .7C

XFSA4AC3 . . . . . . . . . . . . . . .7C

XFSA2ACD3 . . . . . . . . . . . . . .7C

XFSA3A5 . . . . . . . . . . . . . . . .7C

XFSA3BC2 . . . . . . . . . . . . . . .7C

XFSA4AC4 . . . . . . . . . . . . . . .7C

XFSA2ACD4 . . . . . . . . . . . . . .7C

XFSA3AB1 . . . . . . . . . . . . . . .7C

XFSA3BC3 . . . . . . . . . . . . . . .7C

XFSA4AC5 . . . . . . . . . . . . . . .7C

XFSA2ACD5 . . . . . . . . . . . . . .7C

XFSA3AB2 . . . . . . . . . . . . . . .7C

XFSA3BC4 . . . . . . . . . . . . . . .7C

XFSA4ACD1 . . . . . . . . . . . . . .7C

XFSA2ACDRA . . . . . . . . . . . . .7C

XFSA3AB3 . . . . . . . . . . . . . . .7C

XFSA3BC5 . . . . . . . . . . . . . . .7C

XFSA4ACD2 . . . . . . . . . . . . . .7C

XFSA2ACRA . . . . . . . . . . . . . .7C

XFSA3AB4 . . . . . . . . . . . . . . .7C

XFSA3BCD1 . . . . . . . . . . . . . .7C

XFSA4ACD3 . . . . . . . . . . . . . .7C

XFSA2AD1 . . . . . . . . . . . . . . .7C

XFSA3AB5 . . . . . . . . . . . . . . .7C

XFSA3BCD2 . . . . . . . . . . . . . .7C

XFSA4ACD4 . . . . . . . . . . . . . .7C

XFSA2AD2 . . . . . . . . . . . . . . .7C

XFSA3ABC1 . . . . . . . . . . . . . .7C

XFSA3BCD3 . . . . . . . . . . . . . .7C

XFSA4ACD5 . . . . . . . . . . . . . .7C

XFSA2AD3 . . . . . . . . . . . . . . .7C

XFSA3ABC2 . . . . . . . . . . . . . .7C

XFSA3BCD4 . . . . . . . . . . . . . .7C

XFSA4ACDRA . . . . . . . . . . . . .7C

XFSA2AD4 . . . . . . . . . . . . . . .7C

XFSA3ABC3 . . . . . . . . . . . . . .7C

XFSA3BCD5 . . . . . . . . . . . . . .7C

XFSA4ACRA . . . . . . . . . . . . . .7C

XFSA2AD5 . . . . . . . . . . . . . . .7C

XFSA3ABC4 . . . . . . . . . . . . . .7C

XFSA3BCDRA . . . . . . . . . . . . .7C

XFSA4AD1 . . . . . . . . . . . . . . .7C

XFSA2ADRA . . . . . . . . . . . . . .7C

XFSA3ABC5 . . . . . . . . . . . . . .7C

XFSA3BCRA . . . . . . . . . . . . . .7C

XFSA4AD2 . . . . . . . . . . . . . . .7C

XFSA2ARA . . . . . . . . . . . . . . .7C

XFSA3ABCD1 . . . . . . . . . . . . .7C

XFSA3BD1 . . . . . . . . . . . . . . .7C

XFSA4AD3 . . . . . . . . . . . . . . .7C

XFSA2B1 . . . . . . . . . . . . . . . .7C

XFSA3ABCD2 . . . . . . . . . . . . .7C

XFSA3BD2 . . . . . . . . . . . . . . .7C

XFSA4AD4 . . . . . . . . . . . . . . .7C

XFSA2B2 . . . . . . . . . . . . . . . .7C

XFSA3ABCD3 . . . . . . . . . . . . .7C

XFSA3BD3 . . . . . . . . . . . . . . .7C

XFSA4AD5 . . . . . . . . . . . . . . .7C

XFSA2B3 . . . . . . . . . . . . . . . .7C

XFSA3ABCD4 . . . . . . . . . . . . .7C

XFSA3BD4 . . . . . . . . . . . . . . .7C

XFSA4ADRA . . . . . . . . . . . . . .7C

XFSA2B4 . . . . . . . . . . . . . . . .7C

XFSA3ABCD5 . . . . . . . . . . . . .7C

XFSA3BD5 . . . . . . . . . . . . . . .7C

XFSA4ARA . . . . . . . . . . . . . . .7C

XFSA2B5 . . . . . . . . . . . . . . . .7C

XFSA3ABCDRA . . . . . . . . . . .7C

XFSA3BDRA . . . . . . . . . . . . . .7C

XFSA4B1 . . . . . . . . . . . . . . . .7C

XFSA2BC1 . . . . . . . . . . . . . . .7C

XFSA3ABCRA . . . . . . . . . . . . .7C

XFSA3BRA . . . . . . . . . . . . . . .7C

XFSA4B2 . . . . . . . . . . . . . . . .7C

XFSA2BC2 . . . . . . . . . . . . . . .7C

XFSA3ABD1 . . . . . . . . . . . . . .7C

XFSA4A1 . . . . . . . . . . . . . . . .7C

XFSA4B3 . . . . . . . . . . . . . . . .7C

XFSA2BC3 . . . . . . . . . . . . . . .7C

XFSA3ABD2 . . . . . . . . . . . . . .7C

XFSA4A2 . . . . . . . . . . . . . . . .7C

XFSA4B4 . . . . . . . . . . . . . . . .7C

XFSA2BC4 . . . . . . . . . . . . . . .7C

XFSA3ABD3 . . . . . . . . . . . . . .7C

XFSA4A3 . . . . . . . . . . . . . . . .7C

XFSA4B5 . . . . . . . . . . . . . . . .7C

XFSA2BC5 . . . . . . . . . . . . . . .7C

XFSA3ABD4 . . . . . . . . . . . . . .7C

XFSA4A4 . . . . . . . . . . . . . . . .7C

XFSA4BC1 . . . . . . . . . . . . . . .7C

XFSA2BCD1 . . . . . . . . . . . . . .7C

XFSA3ABD5 . . . . . . . . . . . . . .7C

XFSA4A5 . . . . . . . . . . . . . . . .7C

XFSA4BC2 . . . . . . . . . . . . . . .7C

XFSA2BCD2 . . . . . . . . . . . . . .7C

XFSA3ABDRA . . . . . . . . . . . . .7C

XFSA4AB1 . . . . . . . . . . . . . . .7C

XFSA4BC3 . . . . . . . . . . . . . . .7C

XFSA2BCD3 . . . . . . . . . . . . . .7C

XFSA3ABRA . . . . . . . . . . . . . .7C

XFSA4AB2 . . . . . . . . . . . . . . .7C

XFSA4BC4 . . . . . . . . . . . . . . .7C

XFSA2BCD4 . . . . . . . . . . . . . .7C

XFSA3AC1 . . . . . . . . . . . . . . .7C

XFSA4AB3 . . . . . . . . . . . . . . .7C

XFSA4BC5 . . . . . . . . . . . . . . .7C

XFSA2BCD5 . . . . . . . . . . . . . .7C

XFSA3AC2 . . . . . . . . . . . . . . .7C

XFSA4AB4 . . . . . . . . . . . . . . .7C

XFSA4BCD1 . . . . . . . . . . . . . .7C

XFSA2BCDRA . . . . . . . . . . . . .7C

XFSA3AC3 . . . . . . . . . . . . . . .7C

XFSA4AB5 . . . . . . . . . . . . . . .7C

XFSA4BCD2 . . . . . . . . . . . . . .7C

XFSA2BCRA . . . . . . . . . . . . . .7C

XFSA3AC4 . . . . . . . . . . . . . . .7C

XFSA4ABC1 . . . . . . . . . . . . . .7C

XFSA4BCD3 . . . . . . . . . . . . . .7C

XFSA2BD1 . . . . . . . . . . . . . . .7C

XFSA3AC5 . . . . . . . . . . . . . . .7C

XFSA4ABC2 . . . . . . . . . . . . . .7C

XFSA4BCD4 . . . . . . . . . . . . . .7C

372
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 373

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

XFSA4BCD5 . . . . . . . . . . . . . .7C

XGC 30 L . . . . . . . . . . . . . . . .5A

XHD-3 NOT INSTALLED . . . . .5A

XHSPL . . . . . . . . . . . . . . . . . .9A

XFSA4BCDRA . . . . . . . . . . . . .7C

XGC 30 L N4 . . . . . . . . . . . . . .5A

XHD-4 INSTALLED . . . . . . . . .5A

XHSR . . . . . . . . . . . . . . . . . . .9A

XFSA4BCRA . . . . . . . . . . . . . .7C

XGC 30 N4 . . . . . . . . . . . . . . .5A

XHD-4 NOT INSTALLED . . . . .5A

XHSS . . . . . . . . . . . . . . . . . . .9A

XFSA4BD1 . . . . . . . . . . . . . . .7C

XGC 30 SLF . . . . . . . . . . . . . .5A

XHDMC . . . . . . . . . . . . . . . . .9A

XHSSC . . . . . . . . . . . . . . . . . .9A

XFSA4BD2 . . . . . . . . . . . . . . .7C

XGC 30 SLF N4 . . . . . . . . . . . .5A

XHDMCS . . . . . . . . . . . . . . . .9A

XHSSL . . . . . . . . . . . . . . . . . .9A

XFSA4BD3 . . . . . . . . . . . . . . .7C

XGC 40 . . . . . . . . . . . . . . . . . .5A

XHDPB . . . . . . . . . . . . . . . . . .9A

XHSSPL . . . . . . . . . . . . . . . . .9A

XFSA4BD4 . . . . . . . . . . . . . . .7C

XGC 40 L . . . . . . . . . . . . . . . .5A

XHDPBS . . . . . . . . . . . . . . . . .9A

XHSSR . . . . . . . . . . . . . . . . . .9A

XFSA4BD5 . . . . . . . . . . . . . . .7C

XGC 40 L N4 . . . . . . . . . . . . . .5A

XHDPL . . . . . . . . . . . . . . . . . .9A

XHSSS . . . . . . . . . . . . . . . . . .9A

XFSA4BDRA . . . . . . . . . . . . . .7C

XGC 40 N4 . . . . . . . . . . . . . . .5A

XHF-2 INSTALLED . . . . . . . . .5A

XHSSSPL . . . . . . . . . . . . . . . .9A

XFSA4BRA . . . . . . . . . . . . . . .7C

XGC 40 SLF . . . . . . . . . . . . . .5A

XHF-2 NOT INSTALLED . . . . .5A

XIF 030303 . . . . . . . . . . . . . . .5B

XFSAC1 . . . . . . . . . . . . . . . . .7C

XGC 40 SLF N4 . . . . . . . . . . . .5A

XHF-3 INSTALLED . . . . . . . . .5A

XIF 030603 . . . . . . . . . . . . . . .5B

XFSAC2 . . . . . . . . . . . . . . . . .7C

XGC 52 . . . . . . . . . . . . . . . . . .5A

XHF-3 NOT INSTALLED . . . . .5A

XIF 030703 . . . . . . . . . . . . . . .5B

XFSAC3 . . . . . . . . . . . . . . . . .7C

XGC 52 L . . . . . . . . . . . . . . . .5A

XHF-4 INSTALLED . . . . . . . . .5A

XIF 030903 . . . . . . . . . . . . . . .5B

XFSAC4 . . . . . . . . . . . . . . . . .7C

XGC 52 L N4 . . . . . . . . . . . . . .5A

XHF-4 NOT INSTALLED . . . . .5A

XIF 031103 . . . . . . . . . . . . . . .5B

XFSAC5 . . . . . . . . . . . . . . . . .7C

XGC 52 N4 . . . . . . . . . . . . . . .5A

XHFA 31 GB N4 . . . . . . . . . . .5C

XIF 031303 . . . . . . . . . . . . . . .5B

XFSACD1 . . . . . . . . . . . . . . . .7C

XGC 52 SLF . . . . . . . . . . . . . .5A

XHFA 31 N4 . . . . . . . . . . . . . .5C

XIF 031503 . . . . . . . . . . . . . . .5B

XFSACD2 . . . . . . . . . . . . . . . .7C

XGC 52 SLF N4 . . . . . . . . . . . .5A

XHFA 32 GB N4 . . . . . . . . . . .5C

XIF 031803 . . . . . . . . . . . . . . .5B

XFSACD3 . . . . . . . . . . . . . . . .7C

XGC 66 . . . . . . . . . . . . . . . . . .5A

XHFA 32 N4 . . . . . . . . . . . . . .5C

XIF 032403 . . . . . . . . . . . . . . .5B

XFSACD4 . . . . . . . . . . . . . . . .7C

XGC 66 L . . . . . . . . . . . . . . . .5A

XHFA 33 GB N4 . . . . . . . . . . .5C

XIF 033003 . . . . . . . . . . . . . . .5B

XFSACD5 . . . . . . . . . . . . . . . .7C

XGC 66 L N4 . . . . . . . . . . . . . .5A

XHFA 33 N4 . . . . . . . . . . . . . .5C

XIF 033603 . . . . . . . . . . . . . . .5B

XFSACDRA . . . . . . . . . . . . . . .7C

XGC 66 N4 . . . . . . . . . . . . . . .5A

XHFA 41 GB N4 . . . . . . . . . . .5C

XIF 040604 . . . . . . . . . . . . . . .5B

XFSACRA . . . . . . . . . . . . . . . .7C

XGC 66 SLF . . . . . . . . . . . . . .5A

XHFA 41 N4 . . . . . . . . . . . . . .5C

XIF 041204 . . . . . . . . . . . . . . .5B

XFSAD1 . . . . . . . . . . . . . . . . .7C

XGC 66 SLF N4 . . . . . . . . . . . .5A

XHFA 42 GB N4 . . . . . . . . . . .5C

XIF 060606 . . . . . . . . . . . . . . .5B

XFSAD2 . . . . . . . . . . . . . . . . .7C

XGC 80 . . . . . . . . . . . . . . . . . .5A

XHFA 42 N4 . . . . . . . . . . . . . .5C

XIF 060608 . . . . . . . . . . . . . . .5B

XFSAD3 . . . . . . . . . . . . . . . . .7C

XGC 80 L . . . . . . . . . . . . . . . .5A

XHFA 43 GB N4 . . . . . . . . . . .5C

XIF 061206 . . . . . . . . . . . . . . .5B

XFSAD4 . . . . . . . . . . . . . . . . .7C

XGC 80 L N4 . . . . . . . . . . . . . .5A

XHFA 43 N4 . . . . . . . . . . . . . .5C

XIF 061806 . . . . . . . . . . . . . . .5B

XFSAD5 . . . . . . . . . . . . . . . . .7C

XGC 80 N4 . . . . . . . . . . . . . . .5A

XHFG . . . . . . . . . . . . . . . . . . .5C

XIF 062406 . . . . . . . . . . . . . . .5B

XFSADRA . . . . . . . . . . . . . . . .7C

XGC 80 SLF . . . . . . . . . . . . . .5A

XHKSC . . . . . . . . . . . . . . . . . .9A

XIF 063606 . . . . . . . . . . . . . . .5B

XFSB2 . . . . . . . . . . . . . . . . . . .7C

XGC 80 SLF N4 . . . . . . . . . . . .5A

XHKSL . . . . . . . . . . . . . . . . . .9A

XIF 070704 . . . . . . . . . . . . . . .5B

XFSB3 . . . . . . . . . . . . . . . . . . .7C

XGW 0303 . . . . . . . . . . . . . . .5A

XHKSR . . . . . . . . . . . . . . . . . .9A

XIF 071603 . . . . . . . . . . . . . . .5B

XFSB4 . . . . . . . . . . . . . . . . . . .7C

XGW 0305 . . . . . . . . . . . . . . .5A

XHKSS . . . . . . . . . . . . . . . . . .9A

XIF 083206 . . . . . . . . . . . . . . .5B

XFSC . . . . . . . . . . . . . . . . . . .7C

XGW 0307 . . . . . . . . . . . . . . .5A

XHKSSC . . . . . . . . . . . . . . . . .9A

XIFC 030303 . . . . . . . . . . . . . .5B

XFSC-1 . . . . . . . . . . . . . . . . . .7C

XGW 0505 . . . . . . . . . . . . . . .5A

XHKSSL . . . . . . . . . . . . . . . . .9A

XIFC 030603 . . . . . . . . . . . . . .5B

XFSC-2 . . . . . . . . . . . . . . . . . .7C

XGW 0509 . . . . . . . . . . . . . . .5A

XHKSSR . . . . . . . . . . . . . . . . .9A

XIFC 030703 . . . . . . . . . . . . . .5B

XFSC-3 . . . . . . . . . . . . . . . . . .7C

XGW 0707 . . . . . . . . . . . . . . .5A

XHKSSS . . . . . . . . . . . . . . . . .9A

XIFC 030903 . . . . . . . . . . . . . .5B

XFSC-4 . . . . . . . . . . . . . . . . . .7C

XGW 0713 . . . . . . . . . . . . . . .5A

XHMCD . . . . . . . . . . . . . . . . .9A

XIFC 031103 . . . . . . . . . . . . . .5B

XFSC-5 . . . . . . . . . . . . . . . . . .7C

XGW 0909 . . . . . . . . . . . . . . .5A

XHMCMD . . . . . . . . . . . . . . . .9A

XIFC 031303 . . . . . . . . . . . . . .5B

XGC 10 . . . . . . . . . . . . . . . . . .5A

XGW 1111 . . . . . . . . . . . . . . .5A

XHMCMSD . . . . . . . . . . . . . . .9A

XIFC 031503 . . . . . . . . . . . . . .5B

XGC 10 L . . . . . . . . . . . . . . . .5A

XGW 1313 . . . . . . . . . . . . . . .5A

XHMCSD . . . . . . . . . . . . . . . .9A

XIFC 031803 . . . . . . . . . . . . . .5B

XGC 10 L N4 . . . . . . . . . . . . . .5A

XHB-2 INSTALLED . . . . . . . . .5A

XHPB . . . . . . . . . . . . . . . . . . .9A

XIFC 032403 . . . . . . . . . . . . . .5B

XGC 10 N4 . . . . . . . . . . . . . . .5A

XHB-2 NOT INSTALLED . . . . .5A

XHPBM . . . . . . . . . . . . . . . . . .9A

XIFC 033003 . . . . . . . . . . . . . .5B

XGC 10 SLF . . . . . . . . . . . . . .5A

XHB-4 INSTALLED . . . . . . . . .5A

XHPBMS . . . . . . . . . . . . . . . .9A

XIFC 033603 . . . . . . . . . . . . . .5B

XGC 10 SLF N4 . . . . . . . . . . . .5A

XHB-4 NOT INSTALLED . . . . .5A

XHPBPL . . . . . . . . . . . . . . . . .9A

XIFC 040604 . . . . . . . . . . . . . .5B

XGC 20 . . . . . . . . . . . . . . . . . .5A

XHC- 2 INSTALLED . . . . . . . . .5A

XHPBS . . . . . . . . . . . . . . . . . .9A

XIFC 041204 . . . . . . . . . . . . . .5B

XGC 20 L . . . . . . . . . . . . . . . .5A

XHC- 3 INSTALLED . . . . . . . . .5A

XHPBSPL . . . . . . . . . . . . . . . .9A

XIFC 060606 . . . . . . . . . . . . . .5B

XGC 20 L N4 . . . . . . . . . . . . . .5A

XHC-2 NOT INSTALLED . . . . .5A

XHPL . . . . . . . . . . . . . . . . . . .9A

XIFC 060608 . . . . . . . . . . . . . .5B

XGC 20 N4 . . . . . . . . . . . . . . .5A

XHC-3 NOT INSTALLED . . . . .5A

XHPPM . . . . . . . . . . . . . . . . . .9A

XIFC 061206 . . . . . . . . . . . . . .5B

XGC 20 SLF . . . . . . . . . . . . . .5A

XHD- 2 INSTALLED . . . . . . . . .5A

XHPPMS . . . . . . . . . . . . . . . . .9A

XIFC 070704 . . . . . . . . . . . . . .5B

XGC 20 SLF N4 . . . . . . . . . . . .5A

XHD- 3 INSTALLED . . . . . . . . .5A

XHSC . . . . . . . . . . . . . . . . . . .9A

XIHDCX 2 . . . . . . . . . . . . . . . .4A

XGC 30 . . . . . . . . . . . . . . . . . .5A

XHD-2 NOT INSTALLED . . . . .5A

XHSL . . . . . . . . . . . . . . . . . . .9A

XIHDCX 2L . . . . . . . . . . . . . . .4A

373
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 374

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

XIHDCX 3 . . . . . . . . . . . . . . . .4A

XIHSCDGC4 . . . . . . . . . . . . . .4A

XJAB 570 N4 . . . . . . . . . . . .10A

XJAT 890 N4 . . . . . . . . . . . . .10A

XIHDCX 3L . . . . . . . . . . . . . . .4A

XIHSCFC2 . . . . . . . . . . . . . . . .4A

XJAB 690 . . . . . . . . . . . . . . .10A

XJAX 26 . . . . . . . . . . . . . . . .10A

XIHDGCX 2 . . . . . . . . . . . . . . .4A

XIHSCFC3 . . . . . . . . . . . . . . . .4A

XJAB 690 N4 . . . . . . . . . . . .10A

XJAX 26 N4 . . . . . . . . . . . . .10A

XIHDGCX 2L . . . . . . . . . . . . . .4A

XIHSCFC4 . . . . . . . . . . . . . . . .4A

XJAB 890 . . . . . . . . . . . . . . .10A

XJAX 36 . . . . . . . . . . . . . . . .10A

XIHDGCX 3 . . . . . . . . . . . . . . .4A

XIHSDC3 . . . . . . . . . . . . . . . .4A

XJAB 890 N4 . . . . . . . . . . . .10A

XJAX 36 N4 . . . . . . . . . . . . .10A

XIHDGCX 3L . . . . . . . . . . . . . .4A

XIHSDDC4 . . . . . . . . . . . . . . .4A

XJAC 26 . . . . . . . . . . . . . . . .10A

XJAX 46 . . . . . . . . . . . . . . . .10A

XIHFCX 2 . . . . . . . . . . . . . . . .4A

XIHSDDGC3 . . . . . . . . . . . . . .4A

XJAC 26 N4 . . . . . . . . . . . . .10A

XJAX 46 N4 . . . . . . . . . . . . .10A

XIHFCX 2L . . . . . . . . . . . . . . .4A

XIHSDDGC4 . . . . . . . . . . . . . .4A

XJAC 36 . . . . . . . . . . . . . . . .10A

XJAX 570 . . . . . . . . . . . . . . .10A

XIHFCX 3 . . . . . . . . . . . . . . . .4A

XIHSDFC3 . . . . . . . . . . . . . . . .4A

XJAC 36 N4 . . . . . . . . . . . . .10A

XJAX 570 N4 . . . . . . . . . . . .10A

XIHFCX 3L . . . . . . . . . . . . . . .4A

XIHSDFC4 . . . . . . . . . . . . . . . .4A

XJAC 46 . . . . . . . . . . . . . . . .10A

XJAX 690 . . . . . . . . . . . . . . .10A

XIHFGCX 2 . . . . . . . . . . . . . . .4A

XIHSLDC2 . . . . . . . . . . . . . . . .4A

XJAC 46 N4 . . . . . . . . . . . . .10A

XJAX 690 N4 . . . . . . . . . . . .10A

XIHFGCX 2L . . . . . . . . . . . . . .4A

XIHSLDC3 . . . . . . . . . . . . . . . .4A

XJAC 570 . . . . . . . . . . . . . . .10A

XJAX 890 . . . . . . . . . . . . . . .10A

XIHFGCX 3 . . . . . . . . . . . . . . .4A

XIHSLDC4 . . . . . . . . . . . . . . . .4A

XJAC 570 N4 . . . . . . . . . . . .10A

XJAX 890 N4 . . . . . . . . . . . .10A

XIHFGCX 3L . . . . . . . . . . . . . .4A

XIHSLDGC2 . . . . . . . . . . . . . .4A

XJAC 690 . . . . . . . . . . . . . . .10A

XJAY . . . . . . . . . . . . . . . . . . . .5E

XIHLDCX . . . . . . . . . . . . . . . .4A

XIHSLDGC3 . . . . . . . . . . . . . .4A

XJAC 690 N4 . . . . . . . . . . . .10A

XJAY N4 . . . . . . . . . . . . . . . . .5E

XIHLDGCX . . . . . . . . . . . . . . .4A

XIHSLDGC4 . . . . . . . . . . . . . .4A

XJAC 890 . . . . . . . . . . . . . . .10A

XJAYRC . . . . . . . . . . . . . . . . .5E

XIHLFCX . . . . . . . . . . . . . . . . .4A

XIHSLFC2 . . . . . . . . . . . . . . . .4A

XJAC 890 N4 . . . . . . . . . . . .10A

XJBC . . . . . . . . . . . . . . . . . . . .5E

XIHLFGCX . . . . . . . . . . . . . . . .4A

XIHSLFC3 . . . . . . . . . . . . . . . .4A

XJAD 10 . . . . . . . . . . . . . . . .10A

XJBCC 2 . . . . . . . . . . . . . . . . .5E

XIHMDCX . . . . . . . . . . . . . . . .4A

XIHSLFC4 . . . . . . . . . . . . . . . .4A

XJAD 13 . . . . . . . . . . . . . . . .10A

XJBCC 3 . . . . . . . . . . . . . . . . .5E

XIHMDCX2 . . . . . . . . . . . . . . .4A

XIHSTDC2 . . . . . . . . . . . . . . . .4A

XJAD 36 . . . . . . . . . . . . . . . .10A

XJD . . . . . . . . . . . . . . . . . . . . .6A

XIHMDCX2L . . . . . . . . . . . . . .4A

XIHSTDC3 . . . . . . . . . . . . . . . .4A

XJAD 36 N4 . . . . . . . . . . . . .10A

XJD N4 . . . . . . . . . . . . . . . . . .6A

XIHMDCXL . . . . . . . . . . . . . . .4A

XIHSTDC4 . . . . . . . . . . . . . . . .4A

XJAD 4 . . . . . . . . . . . . . . . . .10A

XJDA . . . . . . . . . . . . . . . . . . .6A

XIHMDGCX . . . . . . . . . . . . . . .4A

XIHSTDGC2 . . . . . . . . . . . . . .4A

XJAD 46 . . . . . . . . . . . . . . . .10A

XJDA N4 . . . . . . . . . . . . . . . . .6A

XIHMDGCX2 . . . . . . . . . . . . . .4A

XIHSTDGC3 . . . . . . . . . . . . . .4A

XJAD 46 N4 . . . . . . . . . . . . .10A

XJDAO . . . . . . . . . . . . . . . . . .6A

XIHMDGCX2L . . . . . . . . . . . . .4A

XIHSTDGC4 . . . . . . . . . . . . . .4A

XJAD 6 . . . . . . . . . . . . . . . . .10A

XJDFGC . . . . . . . . . . . . . . . . .6A

XIHMDGCXL . . . . . . . . . . . . . .4A

XIHSTFC2 . . . . . . . . . . . . . . . .4A

XJADC . . . . . . . . . . . . . . . . .10A

XJDFGC N4 . . . . . . . . . . . . . .6A

XIHMFCX . . . . . . . . . . . . . . . .4A

XIHSTFC3 . . . . . . . . . . . . . . . .4A

XJAL 26 . . . . . . . . . . . . . . . .10A

XJDGC . . . . . . . . . . . . . . . . . .6A

XIHMFCX2 . . . . . . . . . . . . . . .4A

XIHSTFC4 . . . . . . . . . . . . . . . .4A

XJAL 26 N4 . . . . . . . . . . . . . .10A

XJDGC N4 . . . . . . . . . . . . . . .6A

XIHMFCX2L . . . . . . . . . . . . . .4A

XIHSXDC2 . . . . . . . . . . . . . . .4A

XJAL 36 . . . . . . . . . . . . . . . .10A

XJDO . . . . . . . . . . . . . . . . . . .6A

XIHMFCXL . . . . . . . . . . . . . . .4A

XIHSXDC3 . . . . . . . . . . . . . . .4A

XJAL 36 N4 . . . . . . . . . . . . . .10A

XJFC 2 . . . . . . . . . . . . . . . . . .5E

XIHMFGCX . . . . . . . . . . . . . . .4A

XIHSXDC4 . . . . . . . . . . . . . . .4A

XJAL 46 . . . . . . . . . . . . . . . .10A

XJFC 3 . . . . . . . . . . . . . . . . . .5E

XIHMFGCX2 . . . . . . . . . . . . . .4A

XIHSXDGC2 . . . . . . . . . . . . . .4A

XJAL 46 N4 . . . . . . . . . . . . . .10A

XJFC 3C2 . . . . . . . . . . . . . . . .5E

XIHMFGCX2L . . . . . . . . . . . . .4A

XIHSXDGC3 . . . . . . . . . . . . . .4A

XJAL 570 . . . . . . . . . . . . . . .10A

XJFC 3C3 . . . . . . . . . . . . . . . .5E

XIHMFGCXL . . . . . . . . . . . . . .4A

XIHSXDGC4 . . . . . . . . . . . . . .4A

XJAL 570 N4 . . . . . . . . . . . . .10A

XJFCC 2 . . . . . . . . . . . . . . . . .5E

XIHMKFCX . . . . . . . . . . . . . . .4A

XIHSXFC2 . . . . . . . . . . . . . . . .4A

XJAL 690 . . . . . . . . . . . . . . .10A

XJFCC 3 . . . . . . . . . . . . . . . . .5E

XIHMKFGCX . . . . . . . . . . . . . .4A

XIHSXFC3 . . . . . . . . . . . . . . . .4A

XJAL 690 N4 . . . . . . . . . . . . .10A

XJHA . . . . . . . . . . . . . . . . . . .6A

XIHSBDC2 . . . . . . . . . . . . . . .4A

XIHSXFC4 . . . . . . . . . . . . . . . .4A

XJAL 890 . . . . . . . . . . . . . . .10A

XJHA N4 . . . . . . . . . . . . . . . . .6A

XIHSBDC3 . . . . . . . . . . . . . . .4A

XIHSYDC23 . . . . . . . . . . . . . .4A

XJAL 890 N4 . . . . . . . . . . . . .10A

XJHAB . . . . . . . . . . . . . . . . . .6A

XIHSBDC4 . . . . . . . . . . . . . . .4A

XIHSYDGC23 . . . . . . . . . . . . .4A

XJAO . . . . . . . . . . . . . . . . . .10A

XJHAB N4 . . . . . . . . . . . . . . .6A

XIHSBDGC2 . . . . . . . . . . . . . .4A

XIHSYFC23 . . . . . . . . . . . . . . .4A

XJAT 26 . . . . . . . . . . . . . . . .10A

XJHABGC . . . . . . . . . . . . . . . .6A

XIHSBDGC3 . . . . . . . . . . . . . .4A

XJA 6 . . . . . . . . . . . . . . . . . .10A

XJAT 26 N4 . . . . . . . . . . . . . .10A

XJHABGC N4 . . . . . . . . . . . . .6A

XIHSBDGC4 . . . . . . . . . . . . . .4A

XJA 6S . . . . . . . . . . . . . . . . .10A

XJAT 36 . . . . . . . . . . . . . . . .10A

XJHAD 12 . . . . . . . . . . . . . . . .6A

XIHSBFC2 . . . . . . . . . . . . . . . .4A

XJA 8 . . . . . . . . . . . . . . . . . .10A

XJAT 36 N4 . . . . . . . . . . . . . .10A

XJHAD 12 N4 . . . . . . . . . . . . .6A

XIHSBFC3 . . . . . . . . . . . . . . . .4A

XJAB 26 . . . . . . . . . . . . . . . .10A

XJAT 46 . . . . . . . . . . . . . . . .10A

XJHAD 6 . . . . . . . . . . . . . . . . .6A

XIHSBFC4 . . . . . . . . . . . . . . . .4A

XJAB 26 N4 . . . . . . . . . . . . .10A

XJAT 46 N4 . . . . . . . . . . . . . .10A

XJHAD 6 N4 . . . . . . . . . . . . . .6A

XIHSCDC2 . . . . . . . . . . . . . . .4A

XJAB 36 . . . . . . . . . . . . . . . .10A

XJAT 570 . . . . . . . . . . . . . . .10A

XJHAD 9 . . . . . . . . . . . . . . . . .6A

XIHSCDC3 . . . . . . . . . . . . . . .4A

XJAB 36 N4 . . . . . . . . . . . . .10A

XJAT 570 N4 . . . . . . . . . . . . .10A

XJHAD 9 N4 . . . . . . . . . . . . . .6A

XIHSCDC4 . . . . . . . . . . . . . . .4A

XJAB 46 . . . . . . . . . . . . . . . .10A

XJAT 690 . . . . . . . . . . . . . . .10A

XJHAGC . . . . . . . . . . . . . . . . .6A

XIHSCDGC2 . . . . . . . . . . . . . .4A

XJAB 46 N4 . . . . . . . . . . . . .10A

XJAT 690 N4 . . . . . . . . . . . . .10A

XJHAGC N4 . . . . . . . . . . . . . .6A

XIHSCDGC3 . . . . . . . . . . . . . .4A

XJAB 570 . . . . . . . . . . . . . . .10A

XJAT 890 . . . . . . . . . . . . . . .10A

XJHB . . . . . . . . . . . . . . . . . . .6A

374
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 375

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

XJHB N4 . . . . . . . . . . . . . . . . .6A

XJLD 4 N4 . . . . . . . . . . . . . . .6A

XJTD 6 N4 . . . . . . . . . . . . . . .6A

XLA-GC . . . . . . . . . . . . . . . . . .9A

XJHBGC . . . . . . . . . . . . . . . . .6A

XJLD 6 . . . . . . . . . . . . . . . . . .6A

XJTFGC . . . . . . . . . . . . . . . . .6A

XLA-GCH . . . . . . . . . . . . . . . .9A

XJHBGC N4 . . . . . . . . . . . . . .6A

XJLD 6 N4 . . . . . . . . . . . . . . .6A

XJTFGC N4 . . . . . . . . . . . . . . .6A

XLA-GH . . . . . . . . . . . . . . . . . .9A

XJHC . . . . . . . . . . . . . . . . . . .6A

XJLGC . . . . . . . . . . . . . . . . . .6A

XJTGC . . . . . . . . . . . . . . . . . .6A

XLAH . . . . . . . . . . . . . . . . . . .9A

XJHC N4 . . . . . . . . . . . . . . . . .6A

XJLGC N4 . . . . . . . . . . . . . . . .6A

XJTGC N4 . . . . . . . . . . . . . . . .6A

XLAL-GH . . . . . . . . . . . . . . . . .9A

XJHCD 12 . . . . . . . . . . . . . . . .6A

XJM . . . . . . . . . . . . . . . . . . . .6A

XJTO . . . . . . . . . . . . . . . . . . .6A

XLAS . . . . . . . . . . . . . . . . . . .9A

XJHCD 12 N4 . . . . . . . . . . . . .6A

XJM N4 . . . . . . . . . . . . . . . . .6A

XJU 23 . . . . . . . . . . . . . . . . . .5E

XLAS-G . . . . . . . . . . . . . . . . . .9A

XJHCD 6 . . . . . . . . . . . . . . . . .6A

XJMA . . . . . . . . . . . . . . . . . . .6A

XJUC 2 . . . . . . . . . . . . . . . . . .5E

XLAS-GH . . . . . . . . . . . . . . . .9A

XJHCD 6 N4 . . . . . . . . . . . . . .6A

XJMA N4 . . . . . . . . . . . . . . . .6A

XJUC 2 XJUDC . . . . . . . . . . . .5E

XLB . . . . . . . . . . . . . . . . . . . . .9A

XJHCD 9 . . . . . . . . . . . . . . . . .6A

XJMAGC . . . . . . . . . . . . . . . . .6A

XJUC 3 . . . . . . . . . . . . . . . . . .5E

XLB-G . . . . . . . . . . . . . . . . . . .9A

XJHCD 9 N4 . . . . . . . . . . . . . .6A

XJMAGC N4 . . . . . . . . . . . . . .6A

XJUC 3 XJUDC . . . . . . . . . . . .5E

XLB-GC . . . . . . . . . . . . . . . . . .9A

XJHCGC . . . . . . . . . . . . . . . . .6A

XJMC . . . . . . . . . . . . . . . . . . .6A

XJUDC . . . . . . . . . . . . . . . . . .5E

XLB-GCH . . . . . . . . . . . . . . . .9A

XJHCGC N4 . . . . . . . . . . . . . .6A

XJMC N4 . . . . . . . . . . . . . . . .6A

XJULB 2 . . . . . . . . . . . . . . . . .5E

XLB-GH . . . . . . . . . . . . . . . . . .9A

XJHO . . . . . . . . . . . . . . . . . . .6A

XJMCGC . . . . . . . . . . . . . . . . .6A

XJULB 2 XJUDC . . . . . . . . . . .5E

XLBL-G . . . . . . . . . . . . . . . . . .9A

XJK . . . . . . . . . . . . . . . . . . . . .6A

XJMCGC N4 . . . . . . . . . . . . . .6A

XJULB 3 . . . . . . . . . . . . . . . . .5E

XLBL-GH . . . . . . . . . . . . . . . . .9A

XJK N4 . . . . . . . . . . . . . . . . . .6A

XJMGC . . . . . . . . . . . . . . . . . .6A

XJULB 3 XJUDC . . . . . . . . . . .5E

XLBS . . . . . . . . . . . . . . . . . . .9A

XJKA . . . . . . . . . . . . . . . . . . . .6A

XJMGC N4 . . . . . . . . . . . . . . .6A

XJW 3 . . . . . . . . . . . . . . . . . . .6A

XLBS-G . . . . . . . . . . . . . . . . . .9A

XJKA N4 . . . . . . . . . . . . . . . . .6A

XJN 12 . . . . . . . . . . . . . . . . . .6A

XJW 3 N4 . . . . . . . . . . . . . . . .6A

XLBS-GH . . . . . . . . . . . . . . . .9A

XJKAD 12 . . . . . . . . . . . . . . . .6A

XJN 12 N4 . . . . . . . . . . . . . . .6A

XJW 5 . . . . . . . . . . . . . . . . . . .6A

XLC . . . . . . . . . . . . . . . . . . . . .9A

XJKAD 12 N4 . . . . . . . . . . . . .6A

XJN 6 . . . . . . . . . . . . . . . . . . .6A

XJW 5 N4 . . . . . . . . . . . . . . . .6A

XLC-G . . . . . . . . . . . . . . . . . . .9A

XJKAD 18 . . . . . . . . . . . . . . . .6A

XJN 6 N4 . . . . . . . . . . . . . . . .6A

XJWH . . . . . . . . . . . . . . . . . . .6A

XLC-GC . . . . . . . . . . . . . . . . . .9A

XJKAD 18 N4 . . . . . . . . . . . . .6A

XJNGC 12 . . . . . . . . . . . . . . . .6A

XJWH 12 . . . . . . . . . . . . . . . .6A

XLC-GCH . . . . . . . . . . . . . . . .9A

XJKAD 6 . . . . . . . . . . . . . . . . .6A

XJNGC 12 N4 . . . . . . . . . . . . .6A

XJWH 12 N4 . . . . . . . . . . . . . .6A

XLC-GH . . . . . . . . . . . . . . . . . .9A

XJKAD 6 N4 . . . . . . . . . . . . . .6A

XJNGC 6 . . . . . . . . . . . . . . . . .6A

XJWH 6 . . . . . . . . . . . . . . . . .6A

XLCS . . . . . . . . . . . . . . . . . . .9A

XJKAGC . . . . . . . . . . . . . . . . .6A

XJNGC 6 N4 . . . . . . . . . . . . . .6A

XJWH 6 N4 . . . . . . . . . . . . . . .6A

XLCS-G . . . . . . . . . . . . . . . . . .9A

XJKAGC N4 . . . . . . . . . . . . . .6A

XJNO . . . . . . . . . . . . . . . . . . .6A

XJWH 9 . . . . . . . . . . . . . . . . .6A

XLCS-GH . . . . . . . . . . . . . . . .9A

XJKB . . . . . . . . . . . . . . . . . . . .6A

XJOGC . . . . . . . . . . . . . . . . . .6A

XJWH 9 N4 . . . . . . . . . . . . . . .6A

XLG . . . . . . . . . . . . . . . . . . . .9A

XJKB N4 . . . . . . . . . . . . . . . . .6A

XJOGC N4 . . . . . . . . . . . . . . .6A

XJWH N4 . . . . . . . . . . . . . . . .6A

XLG-G . . . . . . . . . . . . . . . . . . .9A

XJKBGC . . . . . . . . . . . . . . . . .6A

XJS . . . . . . . . . . . . . . . . . . . . .6A

XJWHGC N4 . . . . . . . . . . . . . .6A

XLG-GC . . . . . . . . . . . . . . . . . .9A

XJKBGC N4 . . . . . . . . . . . . . .6A

XJS N4 . . . . . . . . . . . . . . . . . .6A

XJWHGCX . . . . . . . . . . . . . . .6A

XLG-GCH . . . . . . . . . . . . . . . .9A

XJKD 12 . . . . . . . . . . . . . . . . .6A

XJSD . . . . . . . . . . . . . . . . . . .6A

XJWO . . . . . . . . . . . . . . . . . . .6A

XLG-GH . . . . . . . . . . . . . . . . .9A

XJKD 12 N4 . . . . . . . . . . . . . .6A

XJSD N4 . . . . . . . . . . . . . . . . .6A

XJWT . . . . . . . . . . . . . . . . . . .6A

XLGL-GH . . . . . . . . . . . . . . . .9A

XJKD 18 . . . . . . . . . . . . . . . . .6A

XJSO . . . . . . . . . . . . . . . . . . .6A

XJWT 10 . . . . . . . . . . . . . . . . .6A

XLGS . . . . . . . . . . . . . . . . . . .9A

XJKD 18 N4 . . . . . . . . . . . . . .6A

XJSWGC . . . . . . . . . . . . . . . . .6A

XJWT 10 N4 . . . . . . . . . . . . . .6A

XLGS-G . . . . . . . . . . . . . . . . . .9A

XJKD 6 . . . . . . . . . . . . . . . . . .6A

XJSWGC N4 . . . . . . . . . . . . . .6A

XJWT 13 . . . . . . . . . . . . . . . . .6A

XLGS-GH . . . . . . . . . . . . . . . .9A

XJKD 6 N4 . . . . . . . . . . . . . . .6A

XJT . . . . . . . . . . . . . . . . . . . . .6A

XJWT 13 N4 . . . . . . . . . . . . . .6A

XLP 30320 . . . . . . . . . . . . . . .8C

XJKGC . . . . . . . . . . . . . . . . . .6A

XJT N4 . . . . . . . . . . . . . . . . . .6A

XJWT 4 . . . . . . . . . . . . . . . . . .6A

XLPA . . . . . . . . . . . . . . . . . . . .9A

XJKGC N4 . . . . . . . . . . . . . . . .6A

XJTB . . . . . . . . . . . . . . . . . . . .5E

XJWT 4 N4 . . . . . . . . . . . . . . .6A

XLPAS . . . . . . . . . . . . . . . . . . .9A

XJKO . . . . . . . . . . . . . . . . . . .6A

XJTB 2 . . . . . . . . . . . . . . . . . .5E

XJWT 6 . . . . . . . . . . . . . . . . . .6A

XLPB . . . . . . . . . . . . . . . . . . .9A

XJL . . . . . . . . . . . . . . . . . . . . .6A

XJTB 2 XJUDC . . . . . . . . . . . .5E

XJWT 6 N4 . . . . . . . . . . . . . . .6A

XLPBS . . . . . . . . . . . . . . . . . .9A

XJL N4 . . . . . . . . . . . . . . . . . .6A

XJTB N4 . . . . . . . . . . . . . . . . .5E

XJWT N4 . . . . . . . . . . . . . . . .6A

XLPC . . . . . . . . . . . . . . . . . . .9A

XJLB 2 . . . . . . . . . . . . . . . . . .5E

XJTBGC . . . . . . . . . . . . . . . . .5E

XJWTGC N4 . . . . . . . . . . . . . .6A

XLPCS . . . . . . . . . . . . . . . . . .9A

XJLB 2 XJUDC . . . . . . . . . . . .5E

XJTBGC N4 . . . . . . . . . . . . . . .5E

XJWTGCX . . . . . . . . . . . . . . . .6A

XLPG . . . . . . . . . . . . . . . . . . .9A

XJLB 3 . . . . . . . . . . . . . . . . . .5E

XJTD 10 . . . . . . . . . . . . . . . . .6A

XJX . . . . . . . . . . . . . . . . . . . . .6A

XLPGS . . . . . . . . . . . . . . . . . .9A

XJLB 3 XJUDC . . . . . . . . . . . .5E

XJTD 10 N4 . . . . . . . . . . . . . .6A

XJX N4 . . . . . . . . . . . . . . . . . .6A

XLPR . . . . . . . . . . . . . . . . . . .9A

XJLD 10 . . . . . . . . . . . . . . . . .6A

XJTD 13 . . . . . . . . . . . . . . . . .6A

XJXGC . . . . . . . . . . . . . . . . . .6A

XLPRS . . . . . . . . . . . . . . . . . .9A

XJLD 10 N4 . . . . . . . . . . . . . .6A

XJTD 13 N4 . . . . . . . . . . . . . .6A

XJXGC N4 . . . . . . . . . . . . . . . .6A

XLPW . . . . . . . . . . . . . . . . . . .9A

XJLD 13 . . . . . . . . . . . . . . . . .6A

XJTD 4 . . . . . . . . . . . . . . . . . .6A

XJXO . . . . . . . . . . . . . . . . . . .6A

XLPWS . . . . . . . . . . . . . . . . . .9A

XJLD 13 N4 . . . . . . . . . . . . . .6A

XJTD 4 N4 . . . . . . . . . . . . . . .6A

XLA . . . . . . . . . . . . . . . . . . . . .9A

XLR . . . . . . . . . . . . . . . . . . . . .9A

XJLD 4 . . . . . . . . . . . . . . . . . .6A

XJTD 6 . . . . . . . . . . . . . . . . . .6A

XLA-G . . . . . . . . . . . . . . . . . . .9A

XLR-G . . . . . . . . . . . . . . . . . . .9A

375
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/10/01 5:28 PM Page 376

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

INDEX

XLR-GC . . . . . . . . . . . . . . . . . .9A

XLSWS . . . . . . . . . . . . . . . . . .9A

XMSH 63 . . . . . . . . . . . . . . . .8C

XPB1-N2 . . . . . . . . . . . . . . . . .8A

XLR-GCH . . . . . . . . . . . . . . . .9A

XLSWS-G . . . . . . . . . . . . . . . .9A

XMSH 64 . . . . . . . . . . . . . . . .8C

XPB2-1 . . . . . . . . . . . . . . . . . .8A

XLR-GH . . . . . . . . . . . . . . . . . .9A

XLSWS-GH . . . . . . . . . . . . . . .9A

XMSH N4 . . . . . . . . . . . . . . . .8C

XPB2-12320B1 . . . . . . . . . . . .8A

XLRL-GH . . . . . . . . . . . . . . . . .9A

XLW . . . . . . . . . . . . . . . . . . . .9A

XMSH-N4 . . . . . . . . . . . . . . . .8C

XPB2-12320L1 . . . . . . . . . . . .8A

XLRS . . . . . . . . . . . . . . . . . . .9A

XLW-G . . . . . . . . . . . . . . . . . .9A

XMSQ 65 . . . . . . . . . . . . . . . .8C

XPB2-12320L2 . . . . . . . . . . . .8A

XLRS-G . . . . . . . . . . . . . . . . . .9A

XLW-GC . . . . . . . . . . . . . . . . .9A

XMSQ N4 . . . . . . . . . . . . . . . .8C

XPB2-12320L2 . . . . . . . . . . . .8A

XLRS-GH . . . . . . . . . . . . . . . .9A

XLW-GCH . . . . . . . . . . . . . . . .9A

XMSQ-N4 . . . . . . . . . . . . . . . .8C

XPB2-123L1 . . . . . . . . . . . . . .8A

XLSA . . . . . . . . . . . . . . . . . . .9A

XLW-GH . . . . . . . . . . . . . . . . .9A

XMT . . . . . . . . . . . . . . . . . . . .9A

XPB2-18320B1 . . . . . . . . . . . .8A

XLSA-G . . . . . . . . . . . . . . . . . .9A

XLWL-G . . . . . . . . . . . . . . . . .9A

XNP (Special) . . . . . . . . . . . . .9A

XPB2-18320L1 . . . . . . . . . . . .8A

XLSA-GH . . . . . . . . . . . . . . . .9A

XLWS . . . . . . . . . . . . . . . . . . .9A

XNP (Standard) . . . . . . . . . . . .9A

XPB2-183L1 . . . . . . . . . . . . . .8A

XLSAH . . . . . . . . . . . . . . . . . .9A

XLWS-G . . . . . . . . . . . . . . . . .9A

XNPWB . . . . . . . . . . . . . . . . .9A

XPB2-2 . . . . . . . . . . . . . . . . . .8A

XLSAL-GH . . . . . . . . . . . . . . . .9A

XLWS-GH . . . . . . . . . . . . . . . .9A

XNPWG . . . . . . . . . . . . . . . . .9A

XPB2-24320B1 . . . . . . . . . . . .8A

XLSAS . . . . . . . . . . . . . . . . . .9A

XMB . . . . . . . . . . . . . . . . . . . .9A

XNPWR . . . . . . . . . . . . . . . . .9A

XPB2-24320L1 . . . . . . . . . . . .8A

XLSAS-G . . . . . . . . . . . . . . . . .9A

XMC . . . . . . . . . . . . . . . . . . . .9A

XPB1-1 . . . . . . . . . . . . . . . . . .8A

XPB2-24320L2 . . . . . . . . . . . .8A

XLSAS-GH . . . . . . . . . . . . . . .9A

XMMSA1 . . . . . . . . . . . . . . . .8C

XPB1-121 . . . . . . . . . . . . . . . .8A

XPB2-243L1 . . . . . . . . . . . . . .8A

XLSB . . . . . . . . . . . . . . . . . . .9A

XMMSA2 . . . . . . . . . . . . . . . .8C

XPB1-121B1 . . . . . . . . . . . . . .8A

XPB2-243L2 . . . . . . . . . . . . . .8A

XLSB-G . . . . . . . . . . . . . . . . . .9A

XMNP . . . . . . . . . . . . . . . . . . .9A

XPB1-121L1 . . . . . . . . . . . . . .8A

XPB2-3 . . . . . . . . . . . . . . . . . .8A

XLSB-GH . . . . . . . . . . . . . . . .9A

XMOB-1 . . . . . . . . . . . . . . . . .9A

XPB1-121L2 . . . . . . . . . . . . . .8A

XPB2-303L2 . . . . . . . . . . . . . .8A

XLSBL-GH . . . . . . . . . . . . . . . .9A

XMOB-2 . . . . . . . . . . . . . . . . .9A

XPB1-123 . . . . . . . . . . . . . . . .8A

XPB2-363L2 . . . . . . . . . . . . . .8A

XLSBS . . . . . . . . . . . . . . . . . .9A

XMOB-3 . . . . . . . . . . . . . . . . .9A

XPB1-123B1 . . . . . . . . . . . . . .8A

XPB2-H1 . . . . . . . . . . . . . . . . .8A

XLSBS-G . . . . . . . . . . . . . . . . .9A

XMOB-4 . . . . . . . . . . . . . . . . .9A

XPB1-123L1 . . . . . . . . . . . . . .8A

XPO . . . . . . . . . . . . . . . . . . . .9A

XLSBS-GH . . . . . . . . . . . . . . .9A

XMOBS-1 . . . . . . . . . . . . . . . .9A

XPB1-181 . . . . . . . . . . . . . . . .8A

XPOC . . . . . . . . . . . . . . . . . . .9A

XLSC . . . . . . . . . . . . . . . . . . .9A

XMOBS-2 . . . . . . . . . . . . . . . .9A

XPB1-181B1 . . . . . . . . . . . . . .8A

XPOCH . . . . . . . . . . . . . . . . . .9A

XLSC 2 LESS SWITCH . . . . . .8C

XMOBS-3 . . . . . . . . . . . . . . . .9A

XPB1-181L1 . . . . . . . . . . . . . .8A

XPOCS . . . . . . . . . . . . . . . . . .9A

XLSC 3 LESS SWITCH . . . . . .8C

XMOBS-4 . . . . . . . . . . . . . . . .9A

XPB1-183 . . . . . . . . . . . . . . . .8A

XPOCSH . . . . . . . . . . . . . . . . .9A

XLSC21 . . . . . . . . . . . . . . . . . .8C

XMOLA . . . . . . . . . . . . . . . . . .9A

XPB1-183B1 . . . . . . . . . . . . . .8A

XPOH . . . . . . . . . . . . . . . . . . .9A

XLSC22 . . . . . . . . . . . . . . . . . .8C

XMOLG . . . . . . . . . . . . . . . . .9A

XPB1-183L1 . . . . . . . . . . . . . .8A

XPOS . . . . . . . . . . . . . . . . . . .9A

XLSC31 . . . . . . . . . . . . . . . . . .8C

XMOLR . . . . . . . . . . . . . . . . . .9A

XPB1-2 . . . . . . . . . . . . . . . . . .8A

XPOSH . . . . . . . . . . . . . . . . . .9A

XLSC32 . . . . . . . . . . . . . . . . . .8C

XMOS-1 . . . . . . . . . . . . . . . . .9A

XPB1-2411 . . . . . . . . . . . . . . .8A

XPP . . . . . . . . . . . . . . . . . . . . .9A

XLSC-G . . . . . . . . . . . . . . . . . .9A

XMOS-2 . . . . . . . . . . . . . . . . .9A

XPB1-2412 . . . . . . . . . . . . . . .8A

XPPH . . . . . . . . . . . . . . . . . . .9A

XLSC-GH . . . . . . . . . . . . . . . .9A

XMOS-3 . . . . . . . . . . . . . . . . .9A

XPB1-24120B1 . . . . . . . . . . . .8A

XPP-N4 . . . . . . . . . . . . . . . . . .9A

XLSCS . . . . . . . . . . . . . . . . . .9A

XMOSS-1 . . . . . . . . . . . . . . . .9A

XPB1-24120L1 . . . . . . . . . . . .8A

XRB . . . . . . . . . . . . . . . . . . . .9A

XLSCS-G . . . . . . . . . . . . . . . . .9A

XMOSS-2 . . . . . . . . . . . . . . . .9A

XPB1-24120L2 . . . . . . . . . . . .8A

XRBH . . . . . . . . . . . . . . . . . . .9A

XLSCS-GH . . . . . . . . . . . . . . .9A

XMOSS-3 . . . . . . . . . . . . . . . .9A

XPB1-2431 . . . . . . . . . . . . . . .8A

XRBL . . . . . . . . . . . . . . . . . . .9A

XLSG . . . . . . . . . . . . . . . . . . .9A

XMPP . . . . . . . . . . . . . . . . . . .9A

XPB1-2432 . . . . . . . . . . . . . . .8A

XRBLH . . . . . . . . . . . . . . . . . .9A

XLSG-G . . . . . . . . . . . . . . . . . .9A

XMRSC 60 . . . . . . . . . . . . . . .8C

XPB1-24320B1 . . . . . . . . . . . .8A

XSB 0303 . . . . . . . . . . . . . . . .5A

XLSG-GH . . . . . . . . . . . . . . . .9A

XMRSC 61 . . . . . . . . . . . . . . .8C

XPB1-24320L1 . . . . . . . . . . . .8A

XSB 0306 . . . . . . . . . . . . . . . .5A

XLSGL-GH . . . . . . . . . . . . . . .9A

XMRSC-N4 . . . . . . . . . . . . . . .8C

XPB1-24320L2 . . . . . . . . . . . .8A

XSB 0307 . . . . . . . . . . . . . . . .5A

XLSGS . . . . . . . . . . . . . . . . . .9A

XMRSF 62 . . . . . . . . . . . . . . .8C

XPB1-3 . . . . . . . . . . . . . . . . . .8A

XSB 0309 . . . . . . . . . . . . . . . .5A

XLSGS-G . . . . . . . . . . . . . . . . .9A

XMRSF-N4 . . . . . . . . . . . . . . .8C

XPB1-3012 . . . . . . . . . . . . . . .8A

XSB 0311 . . . . . . . . . . . . . . . .5A

XLSGS-GH . . . . . . . . . . . . . . .9A

XMRSO 63 . . . . . . . . . . . . . . .8C

XPB1-3032 . . . . . . . . . . . . . . .8A

XSB 0313 . . . . . . . . . . . . . . . .5A

XLSR . . . . . . . . . . . . . . . . . . .9A

XMRSO 64 . . . . . . . . . . . . . . .8C

XPB1-30320L2 . . . . . . . . . . . .8A

XSB 0315 . . . . . . . . . . . . . . . .5A

XLSR-G . . . . . . . . . . . . . . . . . .9A

XMRSO-N4 . . . . . . . . . . . . . . .8C

XPB1-3612 . . . . . . . . . . . . . . .8A

XSB 0318 . . . . . . . . . . . . . . . .5A

XLSR-GH . . . . . . . . . . . . . . . .9A

XMSB 60 . . . . . . . . . . . . . . . .8C

XPB1-3632 . . . . . . . . . . . . . . .8A

XSB 0324 . . . . . . . . . . . . . . . .5A

XLSRL-GH . . . . . . . . . . . . . . . .9A

XMSB 61 . . . . . . . . . . . . . . . .8C

XPB1-36320L2 . . . . . . . . . . . .8A

XSB 0330 . . . . . . . . . . . . . . . .5A

XLSRS . . . . . . . . . . . . . . . . . .9A

XMSB N4 . . . . . . . . . . . . . . . .8C

XPB1-G1 . . . . . . . . . . . . . . . . .8A

XSB 0336 . . . . . . . . . . . . . . . .5A

XLSRS-G . . . . . . . . . . . . . . . . .9A

XMSB-N4 . . . . . . . . . . . . . . . .8C

XPB1-G2 . . . . . . . . . . . . . . . . .8A

XSB 0406 . . . . . . . . . . . . . . . .5A

XLSRS-GH . . . . . . . . . . . . . . .9A

XMSD 62 . . . . . . . . . . . . . . . .8C

XPB1-H1 . . . . . . . . . . . . . . . . .8A

XSB 0412 . . . . . . . . . . . . . . . .5A

XLSW . . . . . . . . . . . . . . . . . . .9A

XMSD N4 . . . . . . . . . . . . . . . .8C

XPB1-H2 . . . . . . . . . . . . . . . . .8A

XSB 0416 . . . . . . . . . . . . . . . .5A

XLSWL-GH . . . . . . . . . . . . . . .9A

XMSD-N4 . . . . . . . . . . . . . . . .8C

XPB1-N1 . . . . . . . . . . . . . . . . .8A

XSB 0606 . . . . . . . . . . . . . . . .5A

376
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 5:28 PM Page 377

Index
Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

XSB 0608 . . . . . . . . . . . . . . . .5A

XSIAH12 . . . . . . . . . . . . . . . . .8D

XSM 0718 . . . . . . . . . . . . . . . .5A

XVHPPMS . . . . . . . . . . . . . . . .9A

XSB 0611 . . . . . . . . . . . . . . . .5A

XSIAH18 . . . . . . . . . . . . . . . . .8D

XSM 0808 . . . . . . . . . . . . . . . .5A

XVHSS . . . . . . . . . . . . . . . . . .9A

XSB 0612 . . . . . . . . . . . . . . . .5A

XSIAH25 . . . . . . . . . . . . . . . . .8D

XSM 0810 . . . . . . . . . . . . . . . .5A

XVHSSPL . . . . . . . . . . . . . . . .9A

XSB 0613 . . . . . . . . . . . . . . . .5A

XSIAS . . . . . . . . . . . . . . . . . . .8D

XSM 0812 . . . . . . . . . . . . . . . .5A

XVHSSS . . . . . . . . . . . . . . . . .9A

XSB 0618 . . . . . . . . . . . . . . . .5A

XSIAS12 . . . . . . . . . . . . . . . . .8D

XSM 0911 . . . . . . . . . . . . . . . .5A

XVHSSSPL . . . . . . . . . . . . . . .9A

XSB 0624 . . . . . . . . . . . . . . . .5A

XSIAS17 . . . . . . . . . . . . . . . . .8D

XSM 1010 . . . . . . . . . . . . . . . .5A

XVPO . . . . . . . . . . . . . . . . . . .9A

XSB 0636 . . . . . . . . . . . . . . . .5A

XSIAS25 . . . . . . . . . . . . . . . . .8D

XSM 1014 . . . . . . . . . . . . . . . .5A

XVPOC . . . . . . . . . . . . . . . . . .9A

XSB 0707 . . . . . . . . . . . . . . . .5A

XSIAS9 . . . . . . . . . . . . . . . . . .8D

XSM 1212 . . . . . . . . . . . . . . . .5A

XVPOCS . . . . . . . . . . . . . . . . .9A

XSB 0710 . . . . . . . . . . . . . . . .5A

XSIBD . . . . . . . . . . . . . . . . . . .8D

XSM 1218 . . . . . . . . . . . . . . . .5A

XVPOS . . . . . . . . . . . . . . . . . .9A

XSB 0716 . . . . . . . . . . . . . . . .5A

XSIBD25 . . . . . . . . . . . . . . . . .8D

XSM 1220 . . . . . . . . . . . . . . . .5A

XVS 4 . . . . . . . . . . . . . . . . . . .5D

XSB 0718 . . . . . . . . . . . . . . . .5A

XSIBD32 . . . . . . . . . . . . . . . . .8D

XSM 1224 . . . . . . . . . . . . . . . .5A

XVS 5 . . . . . . . . . . . . . . . . . . .5D

XSB 0808 . . . . . . . . . . . . . . . .5A

XSICA . . . . . . . . . . . . . . . . . . .8D

XSM 1230 . . . . . . . . . . . . . . . .5A

XVS 6 . . . . . . . . . . . . . . . . . . .5D

XSB 0810 . . . . . . . . . . . . . . . .5A

XSICA28 . . . . . . . . . . . . . . . . .8D

XSM 1236 . . . . . . . . . . . . . . . .5A

XVS 8 . . . . . . . . . . . . . . . . . . .5D

XSB 0812 . . . . . . . . . . . . . . . .5A

XSICA32 . . . . . . . . . . . . . . . . .8D

XSM 1246 . . . . . . . . . . . . . . . .5A

XY 2 . . . . . . . . . . . . . . . . . . .10A

XSB 0832 . . . . . . . . . . . . . . . .5A

XSICA41 . . . . . . . . . . . . . . . . .8D

XSM 1414 . . . . . . . . . . . . . . . .5A

XY 3 . . . . . . . . . . . . . . . . . . .10A

XSB 0911 . . . . . . . . . . . . . . . .5A

XSICA54 . . . . . . . . . . . . . . . . .8D

XSM 1422 . . . . . . . . . . . . . . . .5A

XY 34 . . . . . . . . . . . . . . . . . .10A

XSB 1010 . . . . . . . . . . . . . . . .5A

XSICD . . . . . . . . . . . . . . . . . . .8D

XSM 1428 . . . . . . . . . . . . . . . .5A

XY 4 . . . . . . . . . . . . . . . . . . .10A

XSB 1014 . . . . . . . . . . . . . . . .5A

XSICD37 . . . . . . . . . . . . . . . . .8D

XSM 1616 . . . . . . . . . . . . . . . .5A

XY 44 . . . . . . . . . . . . . . . . . .10A

XSB 1212 . . . . . . . . . . . . . . . .5A

XSICD40 . . . . . . . . . . . . . . . . .8D

XSM 1624 . . . . . . . . . . . . . . . .5A

XY 5 . . . . . . . . . . . . . . . . . . .10A

XSB 1218 . . . . . . . . . . . . . . . .5A

XSICD50 . . . . . . . . . . . . . . . . .8D

XSM 1630 . . . . . . . . . . . . . . . .5A

XY 54 . . . . . . . . . . . . . . . . . .10A

XSB 1220 . . . . . . . . . . . . . . . .5A

XSICH . . . . . . . . . . . . . . . . . . .8D

XSM 1646 . . . . . . . . . . . . . . . .5A

XY 6 . . . . . . . . . . . . . . . . . . .10A

XSB 1224 . . . . . . . . . . . . . . . .5A

XSICH32 . . . . . . . . . . . . . . . . .8D

XSM 1818 . . . . . . . . . . . . . . . .5A

XYB 10 . . . . . . . . . . . . . . . . .10A

XSB 1230 . . . . . . . . . . . . . . . .5A

XSICH37 . . . . . . . . . . . . . . . . .8D

XSM 1824 . . . . . . . . . . . . . . . .5A

XYB 104 . . . . . . . . . . . . . . . .10A

XSB 1236 . . . . . . . . . . . . . . . .5A

XSICH44 . . . . . . . . . . . . . . . . .8D

XSM 1830 . . . . . . . . . . . . . . . .5A

XYB 12 . . . . . . . . . . . . . . . . .10A

XSB 1246 . . . . . . . . . . . . . . . .5A

XSICH60 . . . . . . . . . . . . . . . . .8D

XSM 1836 . . . . . . . . . . . . . . . .5A

XYB 124 . . . . . . . . . . . . . . . .10A

XSB 1414 . . . . . . . . . . . . . . . .5A

XSICS . . . . . . . . . . . . . . . . . . .8D

XSM 2424 . . . . . . . . . . . . . . . .5A

XYB 14 . . . . . . . . . . . . . . . . .10A

XSB 1428 . . . . . . . . . . . . . . . .5A

XSICS28 . . . . . . . . . . . . . . . . .8D

XSM 2430 . . . . . . . . . . . . . . . .5A

XYB 144 . . . . . . . . . . . . . . . .10A

XSB 1616 . . . . . . . . . . . . . . . .5A

XSICS32 . . . . . . . . . . . . . . . . .8D

XSM 2436 . . . . . . . . . . . . . . . .5A

XYB 16 . . . . . . . . . . . . . . . . .10A

XSB 1624 . . . . . . . . . . . . . . . .5A

XSICS40 . . . . . . . . . . . . . . . . .8D

XSO 663 B . . . . . . . . . . . . . . .5E

XYB 164 . . . . . . . . . . . . . . . .10A

XSB 1646 . . . . . . . . . . . . . . . .5A

XSICS50 . . . . . . . . . . . . . . . . .8D

XSO 663 S . . . . . . . . . . . . . . .5E

XYB 2 . . . . . . . . . . . . . . . . . .10A

XSB 1818 . . . . . . . . . . . . . . . .5A

XSIDA . . . . . . . . . . . . . . . . . . .8D

XSO 884 . . . . . . . . . . . . . . . . .5E

XYB 3 . . . . . . . . . . . . . . . . . .10A

XSB 1824 . . . . . . . . . . . . . . . .5A

XSIDA65 . . . . . . . . . . . . . . . . .8D

XSO 884 S . . . . . . . . . . . . . . .5E

XYB 34 . . . . . . . . . . . . . . . . .10A

XSB 1830 . . . . . . . . . . . . . . . .5A

XSIDA80 . . . . . . . . . . . . . . . . .8D

XSO 885 . . . . . . . . . . . . . . . . .5E

XYB 4 . . . . . . . . . . . . . . . . . .10A

XSB 1836 . . . . . . . . . . . . . . . .5A

XSIDD . . . . . . . . . . . . . . . . . . .8D

XSSL 4P . . . . . . . . . . . . . . . . .9A

XYB 44 . . . . . . . . . . . . . . . . .10A

XSB 2424 . . . . . . . . . . . . . . . .5A

XSIDD65 . . . . . . . . . . . . . . . . .8D

XSSL 5P . . . . . . . . . . . . . . . . .9A

XYB 5 . . . . . . . . . . . . . . . . . .10A

XSB 2430 . . . . . . . . . . . . . . . .5A

XSIDD80 . . . . . . . . . . . . . . . . .8D

XSSS 4P . . . . . . . . . . . . . . . . .9A

XYB 54 . . . . . . . . . . . . . . . . .10A

XSB 2436 . . . . . . . . . . . . . . . .5A

XSIDH . . . . . . . . . . . . . . . . . . .8D

XSSS 5P . . . . . . . . . . . . . . . . .9A

XYB 6 . . . . . . . . . . . . . . . . . .10A

XSC 16 . . . . . . . . . . . . . . . . .10A

XSIDH73 . . . . . . . . . . . . . . . . .8D

XU 2 . . . . . . . . . . . . . . . . . . .10A

XYB 8 . . . . . . . . . . . . . . . . . .10A

XSC 160 . . . . . . . . . . . . . . . .10A

XSIDS . . . . . . . . . . . . . . . . . . .8D

XU 3 . . . . . . . . . . . . . . . . . . .10A

XYB 84 . . . . . . . . . . . . . . . . .10A

XSC 8 . . . . . . . . . . . . . . . . . .10A

XSIDS65 . . . . . . . . . . . . . . . . .8D

XU 4 . . . . . . . . . . . . . . . . . . .10A

XYBM 10 . . . . . . . . . . . . . . .10A

XSIAA . . . . . . . . . . . . . . . . . . .8D

XSIDS80 . . . . . . . . . . . . . . . . .8D

XUM 2 . . . . . . . . . . . . . . . . .10A

XYBM 104 . . . . . . . . . . . . . .10A

XSIAA11 . . . . . . . . . . . . . . . . .8D

XSIDS95 . . . . . . . . . . . . . . . . .8D

XUM 3 . . . . . . . . . . . . . . . . .10A

XYBM 12 . . . . . . . . . . . . . . .10A

XSIAA25 . . . . . . . . . . . . . . . . .8D

XSIEA . . . . . . . . . . . . . . . . . . .8D

XUM 4 . . . . . . . . . . . . . . . . .10A

XYBM 124 . . . . . . . . . . . . . .10A

XSIAA9 . . . . . . . . . . . . . . . . . .8D

XSIEA110 . . . . . . . . . . . . . . . .8D

XVHKSS . . . . . . . . . . . . . . . . .9A

XYBM 14 . . . . . . . . . . . . . . .10A

XSIAD . . . . . . . . . . . . . . . . . . .8D

XSM 0416 . . . . . . . . . . . . . . . .5A

XVHKSSS . . . . . . . . . . . . . . . .9A

XYBM 144 . . . . . . . . . . . . . .10A

XSIAD12 . . . . . . . . . . . . . . . . .8D

XSM 0608 . . . . . . . . . . . . . . . .5A

XVHPB . . . . . . . . . . . . . . . . . .9A

XYBM 16 . . . . . . . . . . . . . . .10A

XSIAD18 . . . . . . . . . . . . . . . . .8D

XSM 0611 . . . . . . . . . . . . . . . .5A

XVHPBM . . . . . . . . . . . . . . . .9A

XYBM 164 . . . . . . . . . . . . . .10A

XSIAD9 . . . . . . . . . . . . . . . . . .8D

XSM 0612 . . . . . . . . . . . . . . . .5A

XVHPBMS . . . . . . . . . . . . . . .9A

XYBM 2 . . . . . . . . . . . . . . . .10A

XSIAH . . . . . . . . . . . . . . . . . . .8D

XSM 0613 . . . . . . . . . . . . . . . .5A

XVHPBS . . . . . . . . . . . . . . . . .9A

XYBM 3 . . . . . . . . . . . . . . . .10A

XSIAH10 . . . . . . . . . . . . . . . . .8D

XSM 0710 . . . . . . . . . . . . . . . .5A

XVHPPM . . . . . . . . . . . . . . . . .9A

XYBM 34 . . . . . . . . . . . . . . .10A

377
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

INDEX

Catalog
Number

15599 Index 12/11/01 5:57 PM Page 378

Index
Catalog
Number

Catalog
Section

Catalog
Number

Catalog
Section

XYBM 4 . . . . . . . . . . . . . . . .10A

XYC 34 SM . . . . . . . . . . . . . .10A

XYBM 44 . . . . . . . . . . . . . . .10A

XYC 4 . . . . . . . . . . . . . . . . . .10A

XYBM 5 . . . . . . . . . . . . . . . .10A

XYC 4 M . . . . . . . . . . . . . . . .10A

XYBM 54 . . . . . . . . . . . . . . .10A

XYC 4 S . . . . . . . . . . . . . . . .10A

XYBM 6 . . . . . . . . . . . . . . . .10A

XYC 4 SM . . . . . . . . . . . . . . .10A

XYBM 8 . . . . . . . . . . . . . . . .10A

XYC 44 . . . . . . . . . . . . . . . . .10A

XYBM 84 . . . . . . . . . . . . . . .10A

XYC 44 M . . . . . . . . . . . . . . .10A

XYC 10 . . . . . . . . . . . . . . . . .10A

XYC 44 S . . . . . . . . . . . . . . .10A

XYC 10 M . . . . . . . . . . . . . . .10A

XYC 44 SM . . . . . . . . . . . . . .10A

XYC 10 S . . . . . . . . . . . . . . .10A

XYC 5 . . . . . . . . . . . . . . . . . .10A

XYC 10 SM . . . . . . . . . . . . . .10A

XYC 5 M . . . . . . . . . . . . . . . .10A

XYC 104 . . . . . . . . . . . . . . . .10A

XYC 5 S . . . . . . . . . . . . . . . .10A

XYC 104 M . . . . . . . . . . . . . .10A

XYC 5 SM . . . . . . . . . . . . . . .10A

XYC 104 S . . . . . . . . . . . . . .10A

XYC 54 . . . . . . . . . . . . . . . . .10A

XYC 104 SM . . . . . . . . . . . . .10A

XYC 54 M . . . . . . . . . . . . . . .10A

XYC 12 . . . . . . . . . . . . . . . . .10A

XYC 54 S . . . . . . . . . . . . . . .10A

XYC 12 M . . . . . . . . . . . . . . .10A

XYC 54 SM . . . . . . . . . . . . . .10A

XYC 12 S . . . . . . . . . . . . . . .10A

XYC 6 . . . . . . . . . . . . . . . . . .10A

XYC 12 SM . . . . . . . . . . . . . .10A

XYC 6 M . . . . . . . . . . . . . . . .10A

XYC 124 . . . . . . . . . . . . . . . .10A

XYC 6 S . . . . . . . . . . . . . . . .10A

XYC 124 M . . . . . . . . . . . . . .10A

XYC 6 SM . . . . . . . . . . . . . . .10A

XYC 124 S . . . . . . . . . . . . . .10A

XYC 8 . . . . . . . . . . . . . . . . . .10A

XYC 124 SM . . . . . . . . . . . . .10A

XYC 8 M . . . . . . . . . . . . . . . .10A

XYC 14 . . . . . . . . . . . . . . . . .10A

XYC 8 S . . . . . . . . . . . . . . . .10A

XYC 14 M . . . . . . . . . . . . . . .10A

XYC 8 SM . . . . . . . . . . . . . . .10A

XYC 14 S . . . . . . . . . . . . . . .10A

XYC 84 . . . . . . . . . . . . . . . . .10A

XYC 14 SM . . . . . . . . . . . . . .10A

XYC 84 M . . . . . . . . . . . . . . .10A

XYC 144 . . . . . . . . . . . . . . . .10A

XYC 84 S . . . . . . . . . . . . . . .10A

XYC 144 M . . . . . . . . . . . . . .10A

XYC 84 SM . . . . . . . . . . . . . .10A

XYC 144 S . . . . . . . . . . . . . .10A

XYM 2 . . . . . . . . . . . . . . . . . .10A

XYC 144 SM . . . . . . . . . . . . .10A

XYM 3 . . . . . . . . . . . . . . . . . .10A

XYC 16 . . . . . . . . . . . . . . . . .10A

XYM 4 . . . . . . . . . . . . . . . . . .10A

XYC 16 M . . . . . . . . . . . . . . .10A

XYM 5 . . . . . . . . . . . . . . . . . .10A

XYC 16 S . . . . . . . . . . . . . . .10A

XYM 6 . . . . . . . . . . . . . . . . . .10A

XYC 16 SM . . . . . . . . . . . . . .10A

Z-1010 . . . . . . . . . . . . . . . . . .1C

XYC 164 . . . . . . . . . . . . . . . .10A

Z-1011-L . . . . . . . . . . . . . . . . .1C

XYC 164 M . . . . . . . . . . . . . .10A

Z-1011-R . . . . . . . . . . . . . . . . .1C

XYC 164 S . . . . . . . . . . . . . .10A

Z-2011 . . . . . . . . . . . . . . . . . .1C

XYC 164 SM . . . . . . . . . . . . .10A

Z-2033 . . . . . . . . . . . . . . . . . .1C

XYC 2 . . . . . . . . . . . . . . . . . .10A

Z-2034 . . . . . . . . . . . . . . . . . .1C

XYC 2 M . . . . . . . . . . . . . . . .10A
XYC 2 S . . . . . . . . . . . . . . . .10A
XYC 2 SM . . . . . . . . . . . . . . .10A
XYC 3 . . . . . . . . . . . . . . . . . .10A
XYC 3 M . . . . . . . . . . . . . . . .10A
XYC 3 S . . . . . . . . . . . . . . . .10A
XYC 3 SM . . . . . . . . . . . . . . .10A
XYC 34 . . . . . . . . . . . . . . . . .10A
XYC 34 M . . . . . . . . . . . . . . .10A

INDEX

XYC 34 S . . . . . . . . . . . . . . .10A

378
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 6:12 PM Page 379

379
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

NOTES

Notes

15599 Index 12/10/01 6:12 PM Page 380

Notes

NOTES

380
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 6:12 PM Page 381

381
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

NOTES

Notes

15599 Index 12/10/01 6:12 PM Page 382

Notes

NOTES

382
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Index 12/10/01 6:12 PM Page 383

383
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

NOTES

Notes

15599 Index 12/10/01 6:12 PM Page 384

Notes

NOTES

384
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

14743 CB whole catalog 12/2/00 1:01 PM Page 2

For The Latest Product Developments...

Visit www.adalet.com

• Complete Adalet catalog as Acrobat® PDF downloadable files
• New! Circuit Breaker Lighting & Power Distribution
Panelboards brochure as PDF file

Adalet
Adalet, a division of Scott Fetzer, is a leading manufacturer of enclosure systems
and cable accessories. From relay, meter, instrument and junction boxes to control enclosures suitable for NEMA Type 1 through Type 13 applications, motor
starters, control stations and power panels, our enclosures provide
cost-effective solutions to a variety of industry needs. The Adalet line of cable
accessories serves the construction, mining and utility markets with fittings, couplers, splices and terminations for metal clad, paper insulated lead and solid
dielectric applications from 600V to 35KV. To find out more about Adalet products, engineering services and our company-wide commitment to quality, just
give us a call.

Mission Statement
“We are a customer-driven, growth-oriented company which
designs and manufactures engineered enclosures, fittings,
cable accessories and related electrical products for industry.”

www.adalet.com

The information in this catalog is compiled from data which we believe is reliable and is given in good
faith. Since the methods of application and conditions under which our products are used are beyond
our control, we are not able to guarantee the application and/or use of same. The user assumes all risks
and liability in connection with the application and use of our products.
Adalet is not responsible for typographical, illustrative or photographic errors that may appear in this catalog. Adalet reserves the right to make adjustments or corrections due to errors, changing market conditions, product discontinuations or typographical, illustrative or photographic errors. Metric units are
provided for reference only. Specifications subject to change without prior notice. Contact Adalet for the
most current specifications for specific products.

A S C OT T F E T Z E R C O M PA N Y
Enclosure Systems • Cable Accessories

4801 West 150th Street • Cleveland, Ohio 44135 • phone 216.267.9000 • fax 216.267.1681 • info@adalet.com • www.adalet.com
© 2001 Adalet

Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2002:01:18 14:37:47Z
Modify Date                     : 2009:12:11 18:13:24-08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Metadata Date                   : 2009:12:11 18:13:24-08:00
Producer                        : Acrobat Distiller 4.05 for Macintosh
Format                          : application/pdf
Document ID                     : uuid:7f7b0333-2dd0-f649-8db1-8ee1e3ea987d
Instance ID                     : uuid:b554fc2e-bd92-4a49-b8f8-3694bf4201c0
Page Count                      : 388
EXIF Metadata provided by EXIF.tools

Navigation menu