99333 Catalog
2014-09-27
: Pdf 99333-Catalog 99333-Catalog 781063 Batch8 unilog
Open the PDF directly: View PDF .
Page Count: 388
Download | ![]() |
Open PDF In Browser | View PDF |
ADALET A S C O T T F E T Z E R C O M PA N Y INDUSTRIAL ELECTRICAL AND EXPLOSIONPROOF ENCLOSURE SYSTEMS R FO D VE O PR AP GE 2 A EC EL EE P N S CE #NCAT01 ITS N U REV. D 14562 Pg 00-00 12/2/00 12:36 PM Page 1 Designing Our Products Around Yours A SCOTT FETZER COMPANY by Fax 1 4 REGISTER 7 8 2 5 3 6 9 Just photocopy this form and fax your request for information now! (216) 267-1681 Your local Adalet Representative is: Sales and Marketing ATTENTION: FROM: TITLE: COMPANY: ADDRESS: CITY: PHONE: ( STATE: ) FAX: ( ZIP: ) EMAIL ADDRESS Check One ❑ ❑ ❑ ❑ ❑ ❑ Engineering / Design Firm OEM Contractor ❑ I am interested in ADALET products: Distributor End User Other ________________ Please have your sales representative call me. Please send an additional catalog to the following person: NAME: TITLE: COMPANY: ADDRESS: CITY: STATE: SM ADALET Enclosure Systems • Designing Our Products Around Yours ZIP: T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Pg 01-04 12/9/01 3:28 PM Page 1 Table of Contents Pages 1A–1 To 1C–4 SECTION 1 Industrial Electrical Enclosures 1A Stainless Steel Enclosures 1B Aluminum Enclosures 1C Accessories for Stainless Steel & Aluminum Enclosures Pages 2A–1 To 2A–20 SECTION 2 Fiberglass Enclosures 3A Principles, Markings, and How to Select an Increased Safety Terminal Enclosure 3B Increased Safety Terminal Enclosures: TN4 Series, TN4 Expanded Series, TSC Series, TFG Series Pages 3A–1 To 3E–4 SECTION 3 Increased Safety Products 3C HV Series - High Voltage Junction Boxes 3D CN Series 3E Intrinsically Safe Terminal Enclosures Pages 4A–1 To 4B–1 SECTION 4 Explosionproof Instrument Housings 4A Instrument Housings 4B Digital Instrument Enclosures 5A Explosionproof External Flanged Enclosures and Accessories 5B Explosionproof Internal Flanged Enclosures and Accessories Pages 5A–1 To 5E–9 5C Explosionproof Fire Alarm Stations 5D Dust and Watertight Enclosures 5E Multi-Hub Boxes, Thermocouple Head Box Explosionproof Threaded Cover Enclosures SECTION 6 Pages 6A–1 To 6A–15 AutoCAD drawings available upon request. Please contact Adalet engineering department. ADALET Enclosure Systems • Designing Our Products Around Yours SECTION 5 Explosionproof, Dust-Tight, Watertight Enclosures & Accessories SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 1 15599 Pg 01-04 12/9/01 3:28 PM Page 2 Now CENELEC Approved XCEX EExd IIB Includes pushbuttons, selector switches, potentiometers and close up plugs when installed in Adalet enclosures. see SECTION 5A XJ_X Screw Cover Series EExd IIB+H2 Includes pushbuttons, selector switches, potentiometers and close up plugs when installed in Adalet enclosures. see SECTION 6A Instrument Housings EExd IIC (except XDHLX is EExd IIB+H2) XIHX / XDHX series XIHMX / XDHMX series XIHLX / XDHLX series see SECTION 4A Increased Safety Terminal Enclosures EEx'e' II see SECTION 3A 2 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com Explosionproof Control Stations Pages 7A–1 To 7C–7 7A FS Control 7B PriStar 7C Factory-Sealed Control Stations/OmniStar 3 8A 8B 8C 8D 8E Pages 8–A1 To 8E–1 SECTION 8 Motor Control SECTION 7 15599 Pg 01-04 12/11/01 6:58 PM Page 3 Panelboards Circuit Breakers Motor Starters IEC Motor Control Manual Motor Starters Pages 9–A1 To 9A–21 Couplers, Plugs, Receptacles Pages 11–A1 To 11A–40 Hazardous Location Definitions Pages 12–A1 To 12A–6 SECTION 11 Pages 10–A1 To 10A–20 SECTION 12 Explosionproof Fittings, Accessories SECTION 10 SECTION 9 Explosionproof Pilot Devices AutoCAD drawings available upon request. Please contact Adalet engineering department. ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 3 INDEX Index 15599 Pg 01-04 12/9/01 3:28 PM Page 4 Quick Reference Guide METHODS OF PROTECTION Area Division 1 Division 2 Area Zone 0 Zone 1 Zone 2 Protection Method UL CSA CENELEC Explosionproof Intrinsically Safe (2 Fault) Purge/Pressurized (Type X or Y) Nonincendive Non-sparking device Purge/Pressurized (Type Z) Hermetically sealed Any Class I, Division 1 Method Protection Method Intrinsically Safe 'ia' (2 Fault) Flameproof 'd' Increased Safety 'e' Intrinsically Safe 'ib' (1 Fault)0 Encapsulation 'm' Oil Immersion 'o' Purged/Pressurized 'p' Powder filling 'q' Any Zone 0 Method Non-sparking 'nA' Hermetically sealed 'nC' Nonincendive 'nC' Restricted breathing 'nR' Any Zone 0 or 1 Method ANSI/UL 1203 CSA-30 -- -- ANSI/UL 913 CSA-157 -- -- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 UL 1604 CSA-213 CSA-213 --- --- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 CSA-213 -- -- -- -- -- -- UL (AEx) CSA (Ex) CENELEC (EEx) IEC (Ex) UL 2279 Pt. 11 CSA-E79-18 EN 50028 IEC 60 079-18 UL 2279 Pt. 1 UL 2279 Pt. 7 CSA-E79-1 CSA-E79-7 EN 50018 EN 50019 IEC 60 079-1 IEC 60 079-7 UL 2279 Pt. 11 CSA-E79-11 EN 50020 IEC 60 079-11 UL 2279 Pt. 18 UL 2279 UL 2279 Pt. 2 UL 2279 -UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 -- CSA-E79-18 CSA-E79-6 CSA-E79-2 CSA-E79-5 -CSA-E79-15 CSA-E79-15 CSA-E79-15 CSA-E79-15 -- EN 50028 EN 50015 EN 50016 EN 50017 -prEN 50021 prEN 50021 prEN 50021 prEN 50021 -- IEC 60 079-18 IEC 60 079-6 IEC 60 079-2 IEC 60 079-5 -IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 -- TEMPERATURE CLASSES AREA CLASSIFICATIONS Ignitable Materials Present Continuously Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Zone 0 (Zone 20 Dust) Zone 0 Division 1 Zone 1 (Zone 21 Dust) Zone 1 Division 1 Zone 2 (Zone 22 Dust) Zone 2 Division 2 IEC/CENELEC NEC 505 NEC 500 ATEX Classification by Group & Category According to Use Ignitable Materials Present Continuously Equipment Group II Category 1 Equipment (surface) Equipment Group I Category M1 Equipment (mining) IEC Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Category 2 Equipment Category 3 Equipment Category M2 Equipment — GAS GROUPINGS Gas, Dust or Fiber NEC 505/IEC/CENELEC NEC 500 Acetylene Hydrogen Ethylene Propane Methane Metal Dust Coal Dust Grain Dust Fibers Group IIC Group IIC/Group IIB+H2 Group IIB Group IIA Group I (firedamp) None None None None Class I/Group A Class I/Group B Class I/Group C Class I/Group D Class I/Group D Class II/Group E Class II/Group F Class II/Group G Class III ACRONYMS CENELEC - European Committee for Electrotechnical Standardization IEC - International Electrotechnical Commission NEC - National Electrical Code U.L. - Underwriters Laboratories C.S.A. - Canadian Standards Association FM - Factory Mutual BASEEFA - British Approvals Service for Electrical Apparatus in Flammable Atmospheres NFPA - National Fire Protection Agency ISO - International Organization for Standardization ANSI - American National Standard Institute ATEX - Atmospheres Explosibles Maximum Surface Temperature NEC 505 IEC CENELEC 450°C 300°C 280°C 260°C 230°C 215°C 200°C 180°C 165°C 160°C 135°C 120°C 100°C 85°C T1 T2 T3 T4 T5 T6 NEC 500 T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 INGRESS PROTECTION (IP XX) CODES # First Number (Protection against Solid Bodies) Second Number (Protection against Liquids) 0 1 2 3 4 5 6 7 8 No protection Objects greater than 50mm Objects greater than 12mm Objects greater than 2.5mm Object greater than 1mm Dust Protected Dust-tight --- No protection Vertically dripping water 75-90 Deg. dripping water Sprayed water Splashed water Water jets Heavy seas Effects of immersion Indefinite immersion 15599 Sec.1 12/9/01 10:39 AM Page 5 1A–1 NEMA Type 4X JIC Stainless Steel Enclosures – Continuous Hinge Cover These enclosures are suitable for use in areas such as petrochemical plants, dairies, breweries, food processing areas and similar environments where they are subject to frequent high pressure hosing and generally wet conditions. They are also designed for use in areas where severe corrosion problems exist. Type 316 stainless steel enclosures are also suitable for use in offshore applications. (Not submersible.) Construction Adalet’s JN4XHSS enclosures are available in Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. (Replace -SS with -SS6 in catalog number when ordering Type 316 stainless steel.) All seams are continuously welded and ground to a smooth finish. Each enclosure comes complete with four 10-32 weld nuts (for mounting optional panels). Grounding studs are provided on the inside of the box and door, and wall mounting back brackets are welded on the top and bottom outside. The JN4XHSS cover is sealed with a neoprene gasket and is secured to the enclosure with a continuous stainless steel piano hinge on one side and stainless steel door clamping hardware on three sides. There are no knock-outs or holes in the cover or body. Panels Optional panels are available. Panels are fabricated from #14 ga. cold-rolled steel. Finish All enclosures are made from Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. Panels are finished with a high gloss white paint. Standards Shown with optional hinged cover and panel. All JN4XHSS enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R (Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight and Dust-tight) enclosures. These enclosures conform to Joint Industry Council (JIC) standard EGP-1-1967. They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Application Adalet’s JN4XHSS series wall-mounted JIC enclosures are designed to provide protection, indoors and outdoors, against dust, dirt, oil and water for items such as pneumatic or hydraulic instruments, transformers, and junction wiring. Custom units in special sizes or with punching can be supplied. For Type 316 stainless steel enclosures, add 6 after SS (i.e. JN4XHSS6) 5 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 6 NEMA Type 4X JIC Stainless Steel Enclosures – Continuous Hinge Cover 1A–2 Enclosure Catalog Number Gauge A B C Panel Catalog No. D E F G Mounting H M Clamps N JN4XHSS-060403 16 6.00 4.00 3.00 06P04 4.88 2.88 2.55 6.75 2.00 3.00 2.00 JN4XHSS-080604 14 8.00 6.00 4.00 08P06 6.88 4.88 3.55 8.75 4.00 4.00 3.00 JN4XHSS-060404 16 6.00 4.00 4.00 06P04 4.88 2.88 3.55 6.75 2.00 3.00 2.00 JN4XHSS-060604 16 6.00 6.00 4.00 06P06 4.88 4.88 3.55 6.75 4.00 3.00 3.00 JN4XHSS-080804 14 8.00 8.00 4.00 08P08 6.88 6.88 3.55 8.75 6.00 4.00 4.00 JN4XHSS-100804 14 10.00 8.00 4.00 10P08 8.88 6.88 3.55 10.75 6.00 1.63 4.00 JN4XHSS-121005 14 12.00 10.00 5.00 12P10 10.88 8.88 4.55 12.75 8.00 3.63 2.63 JN4XHSS-080606 14 8.00 6.00 6.00 08P06 6.88 4.88 5.55 8.75 4.00 4.00 3.00 JN4XHSS-100806 14 10.00 8.00 6.00 10P08 8.88 6.88 5.55 10.75 6.00 1.63 4.00 JN4XHSS-101006 14 10.00 10.00 6.00 10P10 8.88 8.88 5.55 10.75 8.00 1.63 2.63 JN4XHSS-121206 14 12.00 12.00 6.00 12P12 10.88 10.88 5.55 12.75 10.00 3.63 3.00 JN4XHSS-140806 14 14.00 8.00 6.00 14P08 12.88 6.88 5.55 14.75 6.00 3.63 4.00 JN4XHSS-141206 14 14.00 12.00 6.00 14P12 12.88 10.88 5.55 14.75 10.00 3.63 3.00 JN4XHSS-161406 14 16.00 14.00 6.00 16P14 14.88 12.88 5.55 16.75 12.00 1.63 4.13 JN4XHSS-121008 14 12.00 10.00 8.00 12P10 10.88 8.88 7.55 12.75 8.00 3.63 2.63 JN4XHSS-141208 14 14.00 12.00 8.00 14P12 12.88 10.88 7.55 14.75 10.00 3.63 4.13 JN4XHSS-161408 14 16.00 14.00 8.00 16P14 14.88 12.88 7.55 16.75 12.00 1.63 4.13 JN4XHSS-161410 14 16.00 14.00 10.00 16P14 14.88 12.88 9.55 16.75 12.00 1.63 4.13 All dimensions in inches For Type 316 stainless steel enclosures, add 6 after SS. (i.e. JN4XHSS6) 6 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 7 1A–3 NEMA Type 4X JIC Stainless Steel Enclosures – Lift Off Cover These enclosures are suitable for use in areas such as petrochemical plants, dairies, breweries, food processing areas and similar environments where they are subject to frequent high pressure hosing and generally wet conditions. They are also designed for use in areas where severe corrosion problems exist. Type 316 stainless steel enclosures are also suitable for use in offshore applications. (Not submersible.) Construction Adalet’s JN4XSS enclosures are available in Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. (Replace -XSS with -XSS6 in catalog number when ordering Type 316 stainless steel.) All seams are continuously welded and ground to a smooth finish. Each enclosure comes complete with four 10-32 weld nuts (for mounting optional panels). Grounding studs are provided on the inside of the box and door, and wall mounting back brackets are welded on the top and bottom outside. The JN4XSS cover is sealed with a neoprene gasket and is secured to the enclosure with a continuous stainless steel piano hinge on one side and stainless steel door clamping hardware on three sides. There are no knock-outs or holes in the cover or body. Panels Optional panels are available. Panels are fabricated from cold-rolled steel. Finish All enclosures are made from Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. Panels are finished with a high gloss white paint. Standards Shown with optional panel. All JN4XSS enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R (Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight and Dust-tight) enclosures. These enclosures conform to Joint Industry Council (JIC) standard EGP-1-1967. They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Application Adalet’s JN4XSS series wall-mounted JIC enclosures are designed to provide protection, indoors and outdoors, against dust, dirt, oil and water for items such as pneumatic or hydraulic instruments, transformers, and junction wiring. Custom units in special sizes or with punching can be supplied. For Type 316 stainless steel enclosures, replace SS with SS6 in catalog number (i.e. JN4XSS6) 7 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 8 NEMA Type 4X JIC Stainless Steel Enclosures – Lift Off Cover 1A–4 Enclosure Catalog Number Gauge A B C Panel Catalog No. D E F G Mounting H M Clamps N JN4XSS-060403 16 6.00 4.00 3.00 06P04 4.88 2.88 2.55 6.75 2.00 3.00 2.00 JN4XSS-080604 14 8.00 6.00 4.00 08P06 6.88 4.88 3.55 8.75 4.00 4.00 3.00 JN4XSS-060404 16 6.00 4.00 4.00 06P04 4.88 2.88 3.55 6.75 2.00 3.00 2.00 JN4XSS-060604 16 6.00 6.00 4.00 06P06 4.88 4.88 3.55 6.75 4.00 3.00 3.00 JN4XSS-080804 14 8.00 8.00 4.00 08P08 6.88 6.88 3.55 8.75 6.00 4.00 4.00 JN4XSS-100804 14 10.00 8.00 4.00 10P08 8.88 6.88 3.55 10.75 6.00 1.63 4.00 JN4XSS-121005 14 12.00 10.00 5.00 12P10 10.88 8.88 4.55 12.75 8.00 3.63 2.63 JN4XSS-080606 14 8.00 6.00 6.00 08P06 6.88 4.88 5.55 8.75 4.00 4.00 3.00 JN4XSS-100806 14 10.00 8.00 6.00 10P08 8.88 6.88 5.55 10.75 6.00 1.63 4.00 JN4XSS-101006 14 10.00 10.00 6.00 10P10 8.88 8.88 5.55 10.75 8.00 1.63 2.63 JN4XSS-121206 14 12.00 12.00 6.00 12P12 10.88 10.88 5.55 12.75 10.00 3.63 3.00 JN4XSS-140806 14 14.00 8.00 6.00 14P08 12.88 6.88 5.55 14.75 6.00 3.63 4.00 JN4XSS-141206 14 14.00 12.00 6.00 14P12 12.88 10.88 5.55 14.75 10.00 3.63 3.00 JN4XSS-161406 14 16.00 14.00 6.00 16P14 14.88 12.88 5.55 16.75 12.00 1.63 4.13 JN4XSS-121008 14 12.00 10.00 8.00 12P10 10.88 8.88 7.55 12.75 8.00 3.63 2.63 JN4XSS-141208 14 14.00 12.00 8.00 14P12 12.88 10.88 7.55 14.75 10.00 3.63 4.13 JN4XSS-161408 14 16.00 14.00 8.00 16P14 14.88 12.88 7.55 16.75 12.00 1.63 4.13 JN4XSS-161410 14 16.00 14.00 10.00 16P14 14.88 12.88 9.55 16.75 12.00 1.63 4.13 All dimensions in inches For Type 316 stainless steel enclosures, replace SS with SS6 in catalog number (i.e. JN4XSS6) 8 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 9 NEMA Type 4X Stainless Steel Single Door Enclosures 1A–5 Application Adalet’s N4X single-door wall-mounted enclosures are used indoors and outdoors to house such items as pilot devices, electronic/electrical controls, instrumentation systems, and pneumatic, hydraulic, and machine tool controls. These enclosures are designed to provide protection against dust, dirt, oil and water. They are for use in petrochemical plants, dairies, breweries, food processing areas and similar environments where they are subject to frequent high pressure hosing and generally wet conditions. They are also designed for use in areas where severe corrosion problems exist. Type 316 enclosures are also suitable for use in offshore applications. (Not submersible.) Construction Adalet’s N4X enclosures are available in either Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. (Replace N4X with N4X6 in catalog number when ordering Type 316 stainless steel.) The N4X has continuously welded seams ground to a smooth finish. The N4X enclosure has a folded lip around the door opening to provide complete and maximum gasket contact, and to prevent liquids from dripping into the enclosure when the door is open. Each enclosure comes complete with 3/8 collar studs (for mounting optional panels), 1/4-20 grounding studs, padlock hasp and staple, and optional print pocket. Large N4X enclosures come complete with additional panel mounting studs and maintain a rigid construction through the use of door and body stiffeners. There are no knock-outs or holes in the door or body. Print pockets are furnished upon request and will be shipped loose. Panels Optional panels are available. Panels are fabricated from 12 ga. cold-rolled steel. Finish All enclosures are made from Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. Optional panels are white. Standards All N4X enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R (Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight and Dust-tight) enclosures. These enclosures conform to Joint Industry Council (JIC) standard EGP-1-1967. They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units in special sizes or with punching can be supplied. 9 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 10 NEMA Type 4X Stainless Steel Single Door Enclosures 1A–6 Enclosure Panel No. of Clamps F 6.00 4 1.25 — — V1612 13.00 9.00 6.00 4 3.00 — — V1616 13.00 13.00 20.00 6.00 4 3.00 — — V2016 13.00 17.00 16.00 6.00 4 3.00 — — V2016 17.00 13.00 20.00 20.00 6.00 4 3.00 — — V2020 17.00 17.00 20.00 24.00 6.00 4 3.00 — — V2420 17.00 21.00 14 24.00 12.00 6.00 5 1.25 — — V2412 21.00 9.00 14 24.00 16.00 6.00 5 3.00 — — V2416 21.00 13.00 16 14 24.00 20.00 6.00 5 3.00 — — V2420 21.00 17.00 16 14 24.00 24.00 6.00 5 3.00 — — V2424 21.00 21.00 -302006 14 14 30.00 20.00 6.00 5 3.00 — — V3020 27.00 17.00 -302406 14 14 30.00 24.00 6.00 5 3.00 — — V3024 27.00 21.00 -362406 14 14 36.00 24.00 6.00 5 3.00 — — V3624 33.00 21.00 -363006 14 14 36.00 30.00 6.00 7 3.00 1 — V3630 33.00 27.00 -161208 16 14 16.00 12.00 8.00 4 1.25 — — V1612 13.00 9.00 -161608 16 14 16.00 16.00 8.00 4 3.00 — — V1616 13.00 13.00 -162008 16 14 16.00 20.00 8.00 4 3.00 — — V2016 13.00 17.00 -201608 16 14 20.00 16.00 8.00 4 3.00 — — V2016 17.00 13.00 -202008 16 14 20.00 20.00 8.00 4 3.00 — — V2020 17.00 17.00 -202408 16 14 20.00 24.00 8.00 4 3.00 — — V2420 17.00 21.00 -241608 16 14 24.00 16.00 8.00 5 3.00 — — V2416 21.00 13.00 Catalog # Prefixes Gauge Thickness Box Dimensions B C N4X or N4X6 Box Door A -161206 16 14 16.00 12.00 -161606 16 14 16.00 16.00 -162006 16 14 16.00 -201606 16 14 20.00 -202006 16 14 -202406 16 14 -241206 16 -241606 16 -242006 -242406 Box Stiff. Door Stiff. Qty Qty Panel Catalog # (optional) Panel Dimensions X Y 10 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 11 NEMA Type 4X Stainless Steel Single Door Enclosures Panel No. of Clamps F 8.00 5 3.00 — — V2420 21.00 17.00 8.00 5 3.00 — — V2424 21.00 21.00 30.00 8.00 7 3.00 — — V3024 21.00 27.00 30.00 20.00 8.00 5 3.00 — — V3020 27.00 17.00 14 30.00 24.00 8.00 5 3.00 — — V3024 27.00 21.00 14 14 30.00 30.00 8.00 7 3.00 1 — V3030 27.00 27.00 -362408 14 14 36.00 24.00 8.00 5 3.00 — — V3624 33.00 21.0 -363008 14 14 36.00 30.00 8.00 7 3.00 1 — V3630 33.00 27.00 -363608 14 14 36.00 36.00 8.00 7 3.00 1 1 V3636 33.00 33.00 -423008 14 14 42.00 30.00 8.00 8 3.00 — — V4230 39.00 27.00 -423608 14 14 42.00 36.00 8.00 8 3.00 1 1 V4236 39.00 33.00 -483608 14 14 48.00 36.00 8.00 8 3.00 — — V4836 45.00 33.00 -201610 16 14 20.00 16.00 10.00 4 3.00 — — V2016 17.00 13.00 -202010 16 14 20.00 20.00 10.00 4 3.00 — — V2020 17.00 17.00 -242010 16 14 24.00 20.00 10.00 5 3.00 — — V2420 21.00 17.00 -242410 16 14 24.00 24.00 10.00 5 3.00 — — V2424 21.00 21.00 -302410 14 14 30.00 24.00 10.00 5 3.00 — — V3024 27.00 21.00 -362410 14 14 36.00 24.00 10.00 5 3.00 — — V3624 33.00 21.00 -363010 14 14 36.00 30.00 10.00 7 3.00 1 — V3630 33.00 27.00 -423010 14 14 42.00 30.00 10.00 8 3.00 1 1 V4230 39.00 27.00 -423610 14 14 42.00 36.00 10.00 8 3.00 1 1 V4236 39.00 33.00 -483610 14 14 48.00 36.00 10.00 8 3.00 — — V4836 45.00 33.00 -603610 14 14 60.00 36.00 10.00 9 3.00 — — V6036 57.00 33.00 -201612 16 14 20.00 16.00 12.00 4 3.00 — — V2016 17.00 13.00 -242012 16 14 24.00 20.00 12.00 5 3.00 — — V2420 21.00 17.00 -242412 16 14 24.00 24.00 12.00 5 3.00 — — V2424 21.00 21.00 -302412 14 14 30.00 24.00 12.00 5 3.00 — — V3024 27.00 21.00 -303012 14 14 30.00 30.00 12.00 7 3.00 1 — V3030 27.00 27.00 -362412 14 14 36.00 24.00 12.00 5 3.00 — — V3624 33.00 21.00 -363012 14 14 36.00 30.00 12.00 7 3.00 1 1 V3630 33.00 27.00 -363612 14 14 36.00 36.00 12.00 7 3.00 1 1 V3636 33.00 33.00 -423012 14 14 42.00 30.00 12.00 8 3.00 1 1 V4230 39.00 27.00 -423612 14 14 42.00 36.00 12.00 8 3.00 — — V4236 39.00 33.00 -483612 14 14 48.00 36.00 12.00 8 3.00 — — V4836 45.00 33.00 -603612 14 14 60.00 36.00 12.00 9 3.00 — — V6036 57.00 33.00 -242016 16 14 24.00 20.00 16.00 5 3.00 1 1 V2420 21.00 17.00 -242416 16 14 24.00 24.00 16.00 5 3.00 1 1 V2424 21.00 21.00 -302416 14 14 30.00 24.00 16.00 5 3.00 1 1 V3024 27.00 21.00 -363016 14 14 36.00 30.00 16.00 7 3.00 1 — V3630 33.00 27.00 -423616 14 14 42.00 36.00 16.00 8 3.00 1 1 V4236 39.00 33.00 -483616 14 14 48.00 36.00 16.00 8 3.00 1 1 V4836 45.00 33.00 -603616 14 14 60.00 36.00 16.00 9 3.00 1 1 V6036 57.00 33.00 -302420 14 14 30.00 24.00 20.00 5 3.00 — — V3024 27.00 21.00 -363020 14 14 36.00 30.00 20.00 7 3.00 1 — V3630 33.00 27.00 -483620 14 14 48.00 36.00 20.00 8 3.00 1 1 V4836 45.00 33.00 -603620 14 14 60.00 36.00 20.00 9 3.00 1 1 V6036 57.00 33.00 -302424 14 14 30.00 24.00 24.00 5 3.00 — — V3024 27.00 23.00 Catalog # Prefixes Gauge Thickness Box Dimensions B C N4X or N4X6 Box Door A -242008 16 14 24.00 20.00 -242408 16 14 24.00 24.00 -243008 14 14 24.00 -302008 14 14 -302408 14 -303008 Box Stiff. Door Stiff. Qty Qty Panel Catalog # (optional) Panel Dimensions X Y 11 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 1A–7 Enclosure 15599 Sec.1 12/9/01 10:39 AM Page 12 NEMA Type 4X Victory™ Series Stainless Steel Enclosures 1A–8 These enclosures are designed to provide protection against dust, dirt, oil and water. They are for use in petrochemical plants, dairies, breweries, food processing areas and similar environments where they are subject to frequent high pressure hosing and generally wet conditions. They are also designed for use in areas where severe corrosion problems exist. (Not submersible.) Construction Adalet’s AVSS enclosures are made from Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. (Replace SS with SS6 in catalog when ordering Type 316 stainless steel). All seams are continuously welded and ground to a smooth finish. AVSS enclosures have a formed lip around the door opening to provide complete and maximum gasket contact and to prevent liquids from dripping into the enclosure when the door is open. Each enclosure comes complete with a 1/4-20 grounding stud, 3/8 collar studs (for mounting optional inner panels). Each enclosure door is equipped with a neoprene gasket, 1/4-20 grounding stud and slotted quarter-turn latches to secure the door (optional locking latches are also available). 180° removable hinge. Large enclosures come complete with additional panel mounting studs and maintain a rigid construction through the use of door and body stiffeners. Print pockets are furnished upon request and are shipped loose. Panels Optional panels are available. Panels are fabricated from 12 ga. cold-rolled steel. Finish All enclosures are made from Type 304 or Type 316 stainless steel with a #3 - #4 brush finish. Optional panels are white. Shown with optional panel. Standards Victory Series Enclosures Victory series enclosures feature a streamlined design with a flush door and latches that accommodate any electrical or electronic application. Adalet has designed these enclosures to use quarter-turn latches instead of hold-down clamps (which are often inadequately secured after servicing, leaving equipment vulnerable to the elements). Attractive aluminum die-cast hinges are anodized black. All AVSS enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R (Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant),Type 12 (Industrial Use) and Type 13 (Oiltight and Dust-tight) enclosures. These enclosures conform to Joint Industry Council (JIC) standard EGP-1-1967. They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Application Adalet’s AVSS Victory series stainless steel enclosures are used indoors and outdoors to house such items as electronic/electrical controls, instrumentation systems, pneumatic, hydraulic and machine tool controls. Custom units in special sizes, with punching or with Type 316 stainless steel, can be supplied. See Victory series panels on page 1C–1, and accessories on page 1A–10. 12 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 13 1A–9 NEMA Type 4X Victory™ Series Stainless Steel Enclosures Catalog # Prefix AVSS Prefix AVSS6 -121206 -161206 -161606 -201606 -202006 -241606 -242006 -242406 -161208 -161608 -162008 -201608 -202008 -202408 -241608 -242008 -242408 -243008 -302008 -302408 -303008 -362408 -363008 -363608 -202012 -242012 -242412 -302412 -303012 -362412 -363012 -363612 -423612 -483612 -603612 -242416 -363016 -483616 -242420 -302420 -363020 Gauge Thickness† Box Door 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 16 14 14 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 16 16 16 16 16 16 16 14 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 16 16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 Box Dimension A B 12.00 16.00 16.00 20.00 20.00 24.00 24.00 24.00 16.00 16.00 16.00 20.00 20.00 20.00 24.00 24.00 24.00 24.00 30.00 30.00 30.00 36.00 36.00 36.00 20.00 24.00 24.00 30.00 30.00 36.00 36.00 36.00 42.00 48.00 60.00 24.00 36.00 48.00 24.00 30.00 36.00 12.00 12.00 16.00 16.00 20.00 16.00 20.00 24.00 12.00 16.00 20.00 16.00 20.00 24.00 16.00 20.00 24.00 30.00 20.00 24.00 30.00 24.00 30.00 36.00 20.00 20.00 24.00 24.00 30.00 24.00 30.00 36.00 36.00 36.00 36.00 24.00 30.00 36.00 24.00 24.00 30.00 Latches D E C 6.00 6.00 6.00 6.00 6.00 6.00 6.00 6.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 12.00 16.00 16.00 16.00 20.00 20.00 20.00 1 1 1 2 2 2 2 2 1 1 1 2 2 2 2 2 2 2 3 3 3 3 3 3 2 2 2 3 3 3 3 3 3 4 4 2 3 4 2 3 3 † AVSS6 Series: All 14 ga. ADALET Enclosure Systems • Designing Our Products Around Yours 1 1 1 2 1 1 2 2 2 2 1 2 1 Box Cover Stiffener Qty. Stiffener Qty. 1 1 2 2 1 2 2 2 2 2 2 2 2 1 1 1 1 1 1 - Mounting Centers M N 10.50 14.50 14.50 18.50 18.50 22.50 22.50 22.50 14.50 14.50 14.50 18.50 18.50 18.50 22.50 22.50 22.50 22.50 28.50 28.50 28.50 34.50 34.50 34.50 18.50 22.50 22.50 28.50 28.50 34.50 34.50 34.50 40.50 46.50 58.50 22.50 34.50 46.50 22.50 28.50 34.50 10.50 10.50 14.50 14.50 18.50 14.50 18.50 22.50 10.50 10.50 18.50 14.50 18.50 22.50 14.50 18.50 22.50 28.50 18.50 22.50 28.50 28.50 28.50 34.50 18.50 18.50 22.50 22.50 28.50 22.50 28.50 34.50 34.50 34.50 34.50 22.50 28.50 34.50 22.50 22.50 28.50 Panel Cat. # Optional V1212 V1612 V1616 V2016 V2020 V2416 V2420 V2424 V1612 V1616 V1620 V2016 V2020 V2024 V2416 V2420 V2424 V2430 V3020 V3024 V3030 V3630 V3630 V3636 V2020 V2420 V2424 V3024 V3030 V3624 V3630 V3636 V4236 V4836 V6036 V2424 V3630 V4836 V2424 V3024 V3630 Panel Dim. X Y 9 13 13 17 17 21 21 21 13 13 13 17 17 17 21 21 21 21 27 27 27 33 33 33 17 21 21 27 29 33 33 33 39 45 57 21 33 45 21 27 33 9 9 13 13 17 13 17 21 9 13 17 13 17 21 13 17 21 27 17 21 27 27 27 33 17 17 21 21 27 21 27 33 33 33 33 21 27 33 21 21 27 13 SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 14 Victory™ Series Accessories 1A–10 Wall Mounting Brackets V-SSWMB • • • • • 4 stainless steel brackets Maintain 4, 4X, 12, 13 ratings Field installable No punching or drilling required All hardware included V-SSWMB Locks & Latches Z-2011 Wing knob lock key Z-2033 Wing knob latch Z-2034 Wing knob latch Z-2011 Z-2033 Z-2034 Padlock Kits PCC Covers quarter-turn catch to prevent access (stainless steel) • Maintain 4, 4X, 12, 13 ratings • Field installable • No punching or drilling required PCC 14 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 15 1A–11 NEMA Type 4X Stainless Steel Double Door Enclosures subject to frequent high pressure hosing and generally wet conditions. They are also designed for areas where severe corrosion problems exist. (Not submersible.) Construction Adalet’s N4X-DD-SS enclosures are made from 12 ga. Type 304 stainless steel with a #4 brush finish. All seams are continuously welded and ground to a smooth finish. The N4X-DD-SS enclosure has a folded lip around the door opening to provide complete and maximum gasket contact, and to prevent liquids from dripping into the enclosure when doors are open. Each enclosure comes complete with 3/8 collar studs (for mounting optional panels) and two support brackets welded to the bottom of the enclosure to aid in optional panel installation. Each enclosure is equipped with 1/4-20 grounding studs, and two 5/8 eye bolts complete with solid rubber seals and reinforcing support angles welded to the top of the enclosure for easy handling. The N4XDD-SS enclosures are equipped with wall mounting brackets and body stiffeners. Each enclosure door is equipped with a neoprene gasket, removable print pocket, 1/4-20 grounding studs, stainless steel door clamping hardware on three sides and padlocking hasp. Each door rests on a removable center mullion which also provides for easy panel installation. Doors are easily removed by pulling the pin on the continuous stainless steel piano hinge. There are no knock-outs or holes in the doors or body. Panels Optional panels are available. Panels are fabricated from 12 ga. cold-rolled steel. Finish All enclosures are made from Type 304 stainless steel with a #4 brush finish. Panels are finished with a high gloss white polyester powder coating. Standards Shown with optional panel. Application Adalet’s N4X-DD-SS double-door enclosures are used indoors and outdoors to house such items as electronic/electrical controls, instrumentation systems, and pneumatic, hydraulic, and machine tool controls. These enclosures are designed to provide protection against dust, dirt, oil and water. They are suitable for use in petrochemical plants, dairies, breweries, food processing areas and similar environments where they are All N4X-DD-SS enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 3R (Rainproof and Sleet/Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Industrial Use) and Type 13 (Oiltight and Dust-tight) enclosures. These enclosures conform to Joint Industry Council (JIC) standard EGP-11967. They are listed by Underwriters Laboratories, Inc. (UL) and are certified by the Canadian Standards Association (CSA). Special Orders Custom units in special sizes, with punching or with Type 316 stainless steel, can be supplied. 15 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 16 NEMA Type 4X Stainless Steel Double Door Enclosures 1A–12 A B 5/8 EYEBOLTS C 3 1 3/8 2 1 1/4 B-4 A-3 1/2 OPENING 2 PADLOCK PROVISION A-2 1/2 1/3 A A-4 Z A Z 2 A PRINT POCKET SECTION A-A DOOR CLAMP MAX 18" CENTERS B/2-2 1/2 B/2-2 1/2 1 1/4 GASKET PANEL 1 1/16 1 3/4 BRACING B/2-3 1/2 OPENING B/2-3 1/2 OPENING 3 1/2 C 1 3/4 7/8 B-4 3/8 COLLAR STUD 2 SECTION Z-Z 1 1/8 B Enclosure Panel Catalog Number A Size B C Catalog Number N4X-DD-SS-604812 N4X-DD-SS-606012 N4X-DD-SS-726012 N4X-DD-SS-727212 60 60 72 72 48 60 60 72 12 12 12 12 D-60P48 D-60P60 D-72P60 D-72P72 Size 56X44 56X56 68X56 68X68 All dimensions in inches 16 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 17 1B–1 NEMA Type 4X JIC Aluminum Enclosures – Continuous Hinge Cover Application Adalet's JN4XHA aluminum wall-mounted enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water for items such as hydraulic or pneumatic instruments, transformers, and junction wiring. These lightweight enclosures are suitable for applications in petrochemical plants, marine areas, sewage plants, areas containing solvents, and similar environments where they can be subject to frequent high pressure hosing and generally wet conditions. They are not for use in areas where severe corrosion problems exist. (Not submersible.) Construction Adalet's JN4XHA enclosures are available in Type 5052H32 aluminum with a brushed finish. The enclosure has continuously welded seams ground to a smooth finish. It also comes complete with four 10-32 standoffs (for mounting optional panels). Grounding studs are provided on the inside of the box only, and wall mounting back brackets are mechanically clinched on the top and bottom outside. The JN4XHA cover is sealed with a neoprene gasket and is secured to the enclosure with a mechanically clinched continuous aluminum piano hinge on one side and stainless steel door clamping hardware on three sides. There are no knock-outs or holes in the cover or body. Panels Optional panels are available. Panels are fabricated from 14 ga. cold-rolled steel and are powder coated white. Standards All JN4XHA enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet / Ice Resistant), Type 3R (Rainproof and Sleet / Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 13 (Oiltight and Dust-tight) enclosures. They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Shown with optional panel. Custom units in special sizes or with punching can be supplied. 17 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 18 NEMA Type 4X JIC Aluminum Enclosures – Continuous Hinge Cover 1B–2 Catalog No. Dimensions (in) HxWxD Material Thickness Box / Cover Weight (lbs) Panel Catalog No. Panel Size (in) X xY JN4XHA-060604 6x6x4 0.08 / 0.08 1 1 6.75 4.00 2 06P06 4.88 x 4.88 JN4XHA-080604 8x6x4 0.08 / 0.08 1 1 8.75 4.00 2 08P06 6.88 x 4.88 JN4XHA-100804 10 x 8 x 4 0.08 / 0.08 2 1 10.75 6.00 3 10P08 8.88 x 6.88 JN4XHA-121005 12 x 10 x 5 0.08 / 0.08 2 2 12.75 8.00 5 12P10 10.88 x 8.88 JN4XHA-141206 14 x 12 x 6 0.08 / 0.08 2 2 14.75 10.00 7 14P12 12.88 x 10.88 JN4XHA-161406 16 x 14 x 6 0.08 / 0.08 3 2 16.75 12.00 8 16P14 14.88 x 12.88 Hold Downs H side W side Mounting Dim. (in) M N All dimensions in inches 18 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 19 NEMA Type 4X Aluminum Single Door Enclosures 1B–3 Application Adalet's N4XA aluminum single door wall-mount enclosure can be used indoors or outdoors to house items such as pilot devices, electronic or electrical controls, instrumentation systems, and hydraulic, pneumatic and machine tool controls. These enclosures are designed to protect against dust, dirt, oil and water. They are suitable for applications in petrochemical plants, marine areas, sewage plants, areas containing solvents, and similar environments where they can be subject to frequent high pressure hosing and generally wet conditions. They are not for use in areas where severe corrosion problems exist. (Not submersible.) Construction Adalet's N4XA enclosures are available in Type 5052-H32 aluminum with a smooth brushed finish. The enclosure has continuously welded seams ground to a smooth finish. Around the door opening it has a folded lip consisting of multiple 90 degree bends. This provides complete and maximum gasket contact, and prevents liquids from dripping into the enclosure when the door is open. Each enclosure comes complete with 3/8 collar studs (for mounting optional panels), 1⁄4-20 grounding studs on inside of box, padlock hasp & staple. The continuous piano hinge and mounting feet are secured to the box by mechanical clinching. Panels Optional panels are available. Panels are fabricated from 12 ga. cold-rolled steel and are powder coated white. Standards All N4XA enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet / Ice Resistant), Type 3R (Rainproof and Sleet / Ice Resistant), Type 4 (Watertight and Dust-tight), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 13 (Oiltight and Dust-tight) enclosures. They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units in special sizes or with punching can be supplied. 19 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 20 NEMA Type 4X Aluminum Single Door Enclosures 1B–4 Catalog No. Dimensions (in) HxWxD Material Thickness Box / Cover N4XA-161206 16 x 12 x 6 0.08 / 0.08 2 1 17.25 9.50 10 V1612 13.00 x 9.00 N4XA-201606 20 x 16 x 6 0.08 / 0.08 2 1 21.25 10.00 13 V2016 17.00 x 13.00 N4XA-202006 20 x 20 x 6 0.08 / 0.08 2 1 21.25 14.00 16 V2020 17.00 x 17.00 N4XA-242006 24 x 20 x 6 0.08 / 0.08 3 1 25.25 14.00 18 V2420 21.00 x 17.00 N4XA-161608 16 x 16 x 8 0.08 / 0.08 2 1 17.25 10.00 13 V1616 13.00 x 13.00 N4XA-242408 24 x 24 x 8 0.08 / 0.08 3 1 25.25 18.00 23 V2424 21.00 x 21.00 N4XA-302408 30 x 24 x 8 0.08 / 0.08 3 1 31.25 18.00 27 V3024 27.00 x 21.00 N4XA-362408 36 x 24 x 8 0.08 / 0.08 3 1 37.25 18.00 30 V3624 33.00 x 21.00 N4XA-363008 36 x 30 x 8 0.08 / 0.08 3 2 37.25 24.00 37 V3630 33.00 x 27.00 N4XA-483608 48 x 36 x 8 0.08 / 0.08 4 2 49.25 30.00 52 V4836 45.00 x 33.00 N4XA-201610 20 x 16 x 10 0.08 / 0.08 2 1 21.25 10.00 16 V2016 17.00 x 13.00 N4XA-242010 24 x 20 x 10 0.08 / 0.08 3 1 25.25 14.00 21 V2420 21.00 x 17.00 N4XA-302412 30 x 24 x 12 0.08 / 0.08 3 1 31.25 18.00 32 V3024 27.00 x 21.00 N4XA-363012 36 x 30 x 12 0.08 / 0.08 3 2 37.25 24.00 43 V3630 33.00 x 27.00 Hold Downs H side W side Mounting Dim. (in) M N Weight (lbs) Panel Catalog No. Panel Size (in) X xY All dimensions in inches 20 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 21 1C–1 Accessory Inner Panels Panels for N4X Single Door and Victory Series Enclosures 12 Ga. Steel with White Polyester Powder Coat Finish Catalog Number Panels for N4X JIC Enclosures 14 Ga. Steel with White Polyester Powder Coat Finish Catalog Number For Enclosure Panel Size 06P04 06P06 08P06 08P08 10P08 6x4 6x6 8x6 8x8 10 x 8 4 4 6 6 8 10P10 12P10 12P12 14P08 10 x 10 12 x 10 12 x 12 14 x 8 8 7/8 10 7/8 10 7/8 12 7/8 8 7/8 8 7/8 10 7/8 6 7/8 14P12 16P14 14 x 12 16 x 14 12 7/8 14 7/8 10 7/8 12 7/8 H For Enclosure Panel Size H W V-1212 V-1612 V-1616 V-2016 12 16 16 20 16 x x x x x 12 12 16 16 20 9 13 13 17 9 9 13 13 V-2020 V-2412 V-2416 V-2420 20 24 24 24 20 x x x x x 20 12 16 20 24 17 21 21 21 17 9 13 17 V-2424 V-3020 V-3024 x x x x x 24 20 24 30 30 21 27 27 21 17 21 V-3030 24 30 30 24 30 27 27 V-3624 V-3630 V-3636 36 x 24 36 x 30 36 x 36 33 33 33 21 27 33 V-4230 V-4236 V-4836 42 x 30 42 x 36 48 x 36 39 39 45 27 33 33 V-6036 60 x 36 57 33 All dimensions in inches W 7/8 7/8 7/8 7/8 7/8 2 4 4 6 6 7/8 7/8 7/8 7/8 7/8 Special Orders Custom sizes and panels fabricated from stainless steel and aluminum are available. Consult factory for more information. All dimensions in inches 21 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 22 Floor Stand Kit 1C–2 Application Kits, consisting of two mounting feet, are designed for easy installation on most wall-mounted enclosures. Mounting feet enable enclosures to be floor mounted, and at the same time raise the enclosure 12" from the ground to clear flood levels or for easy working access. Construction Mounting feet are made from Type 304 stainless steel and are pre-punched for ease of mounting to both floor and enclosure. Each kit comes complete with necessary hardware for mounting. Catalog Number 12MF-12-SS Height Enclosure Depth 12 12 All dimensions in inches Special Orders Custom units made with special heights, depths or materials can be supplied. 22 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 23 1C–3 Latches, Locks and Handles Vault Type Locking Handle 7" long cadmium plated padlocking handle Cat. No. Z-1010 No. Z-1010 Automotive Locking Handle 4 1/2" chrome plated key locking handle Cat. No. Z-1011-L (Clockwise Turn) Cat. No. Z-1011-R (Counterclockwise Turn) No. Z-1011 Wing Knob Key Lock Quarter-turn lock Cat. No. Z-2011 No. Z-2011 Wing Knob Latch Quarter-turn lock Cat. No. Z-2033 No. Z-2033 Wing Knob Latch Quarter-turn lock Cat. No. Z-2034 No. Z-2034 23 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.1 12/9/01 10:39 AM Page 24 Other Accessories 1C–4 Gasket For Type 4X enclosures – 80' per roll Closed-cell neoprene sponge with rubber-based adhesive (.25" thick x 1" wide) Cat. No. M1423 24 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 25 NEMA Type 4X Pushbutton Fiberglass Enclosures Application The pushbutton fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water for items such as pushbuttons, pilot lights and switches. Designed for installation of standard 30mm operators. 2A–1 Construction The pushbutton enclosures are constructed of compression molded, fiberglass reinforced polyester with covers flush with enclosures sides. Cover gasket is a continuous urethane material. Cover screws are recessed and made of stainless steel. A metal grounding strap is supplied. Interior mounting wells are gasketed and sealed from the inside. There are no external mounting feet with this enclosure. Machine tool gray color. Panels There are no panel provisions with these enclosures. Standards All pushbutton fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant) and Type 12 (Dust-tight). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 25 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 26 NEMA Type 4X Pushbutton Fiberglass Enclosures C A M 2.25 H 2A–2 2.25 N SEE DETAIL A W Ø.22 .22 (4)PLACES .67 .19 .67 B D Ø1.21 1.21 DETAIL A Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-1PB 6.63 x 3.81 x 3.89 6 x 3.19 x 3.63 4.88 N4X-FG-2PB 6.63 x 3.81 x 3.89 6 x 3.19 x 3.63 N4X-FG-3PB 8.88 x 3.81 x 3.89 8.26 x 3.19 x 3.63 Mounting Dim. (in) M N Weight (lbs) Panel Catalog No. Panel Size (in) 2.94 2 No Panel NA 4.88 2.94 2 No Panel NA 7.13 2.94 2 No Panel NA All dimensions in inches 26 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 27 NEMA Type 4X Flush Cover Fiberglass Enclosures Application The flush cover fiberglass enclosure can be used indoors or outdoors to house items such as standard size pushbuttons, pilot lights and switches. These enclosures are designed to protect against dust, dirt, oil and water. Construction 2A–3 The flush cover enclosures are constructed of compression molded, fiberglass reinforced polyester. The covers are flush with sides of enclosure. Cover gasket is a continuous urethane material. Recessed cover screws are made of stainless steel. Interior mounting wells are gasketed and sealed from the inside. There are no external mounting feet with this enclosure. Machine tool gray color. Panels There are no panel provisions with these enclosures. Standards All flush cover fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 27 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 28 NEMA Type 4X Flush Cover Fiberglass Enclosures C H M 2A–4 A N W Ø.22 (4)PLACES D B Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-030302 3.72 x 3.63 x 2.95 3.13 x 3.03 x 2.7 2.31 N4X-FG-050302 5.97 x 3.63 x 3.14 5.38 x 3.03 x 2.87 N4X-FG-060404 6.63 x 3.81 x 3.89 N4X-FG-080404 N4X-FG-110404 Mounting Dim. (in) M N Weight (lbs) Panel Catalog No. Panel Size (in) 2.75 1 No Panel NA 4.56 2.75 1 No Panel NA 6 x 3.19 x 3.63 4.88 2.94 2 No Panel NA 8.88 x 3.81 x 3.89 8.26 x 3.19 x 3.63 7.13 2.94 2 No Panel NA 11.13 x 3.81 x 3.89 10.51 x 3.19 x 3.63 9.37 2.94 2 No Panel NA All dimensions in inches 28 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 29 NEMA Type 4X Small Screw Cover Fiberglass Enclosures Application The screw cover junction fiberglass enclosure can be used indoors or outdoors to house items such as standard size pushbuttons, pilot lights and switches. These enclosures are designed to protect against dust, dirt, oil and water. 2A–5 Construction The screw cover junction enclosures are constructed of compression molded, fiberglass reinforced polyester. The covers are flush with sides of enclosure. The captive cover screws are made of stainless steel. The cover gasket is a continuous urethane material. Interior panel mounting inserts are molded to enclosure. There are no external mounting feet with this enclosure. Machine tool gray color. Panels Panels are not available with these enclosures. Standards All small screw cover junction fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 29 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 30 NEMA Type 4X Small Screw Cover Fiberglass Enclosures C N A H M 2A–6 W Ø.22 (4) PLACES D B Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-070603 7.63 x 6.63 x 3.19 6.9 x 5.9 x 2.88 5.37 N4X-FG-090603 9.87 x 6.63 x 3.19 9.15 x 5.9 x 2.88 7.62 Mounting Dim. (in) M N Weight (lbs) Panel Catalog No. Panel Size (in) 5.63 2 No Panel NA 5.63 2 No Panel NA All dimensions in inches 30 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 31 NEMA Type 4X Screw Cover Fiberglass Enclosures Application The screw cover fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed for use as a terminal wiring box, instrumentation housing or electrical control enclosure. Construction 2A–7 The screw cover enclosures are constructed of compression molded, fiberglass reinforced polyester with stainless steel captive cover screws. The cover gasket is a continuous urethane material. A stainless steel retaining chain is attached to the cover and enclosure. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.080” aluminum. Standards All screw cover fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 31 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 32 NEMA Type 4X Screw Cover Fiberglass Enclosures MOUNTING MOUNTINGPANEL PANEL (ORDERSEPARATELY) SEPARATELY (ORDER 0.31 PLACES ÿ.31 .31 (4) PLACES N H A 2A–8 M C W D P B Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD M N4X-FG-060604SC 7.50 x 7.50 x 4.75 5.72 x 5.72 x 4.45 6.75 4.00 N4X-FG-080604SC 9.62 x 7.50 x 4.74 7.73 x 5.74 x 4.45 8.88 N4X-FG-100804SC 11.62 x 9.41 x 4.25 9.73 x 7.73 x 3.98 N4X-FG-121005SC 13.56 x 11.43 x 5.21 N4X-FG-141206SC 15.50 x 13.50 x 6.25 Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 4.00 3 BP66A 4.88 x 4.88 4.00 4.00 4 BP86A 6.88 x 4.88 10.75 6.00 3.50 5 BP108A 8.88 x 6.88 11.79 x 9.8 x 4.94 12.75 8.00 4.50 7 BP1210A 10.88 x 8.88 13.53 x 11.55 x 5.94 14.62 10.00 5.37 9 BP1412A 12.88 x 10.90 All dimensions in inches 32 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 33 NEMA Type 4X Hinged Screw Cover Fiberglass Enclosures Application The hinged screw cover fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed for use as a terminal wiring box, instrumentation housing or electrical control enclosure where a hinged cover is desired. 2A–9 Construction The hinged screw cover enclosures are constructed of compression molded, fiberglass reinforced polyester. Enclosure includes a stainless steel continuous hinge with stainless steel captive cover screws. The cover gasket is a continuous urethane material. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.080” aluminum. Standards All hinged screw cover fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 33 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 34 NEMA Type 4X Hinged Screw Cover Fiberglass Enclosures MOUNTING PANEL (ORDER SEPARATELY) Ø.31 (4) PLACES N H A 2A–10 M C W Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-060604CHSC 7.50 x 7.50 x 4.75 5.72 x 5.72 x 4.45 N4X-FG-080604CHSC 9.62 x 7.50 x 4.74 N4X-FG-100804CHSC D P B M Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 6.75 4.00 4.00 3 BP66A 4.88 x 4.88 7.73 x 5.74 x 4.45 8.88 4.00 4.00 4 BP86A 6.88 x 4.88 11.62 x 9.41 x 4.25 9.73 x 7.73 x 3.98 10.75 6.00 3.50 5 BP108A 8.88 x 6.88 N4X-FG-121005CHSC 13.56 x 11.43 x 5.21 11.79 x 9.80 x 4.94 12.75 8.00 4.50 7 BP1210A 10.88 x 8.88 N4X-FG-141206CHSC 15.50 x 13.50 x 6.25 13.53 x 11.55 x 5.94 14.62 10.00 5.37 9 BP1412A 12.88 x 10.90 N4X-FG-161406CHSC 17.53 x 15.46 x 6.23 15.63 x 13.60 x 5.94 16.75 12.00 5.36 12 BP1614A 14.88 x 12.90 N4X-FG-181608CHSC 19.62 x 17.61 x 8.82 17.69 x 15.69 x 8.45 18.88 12.00 7.99 19 BP1816A 16.88 x 14.90 All dimensions in inches 34 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 35 NEMA Type 4X Quick Release Latch Fiberglass Enclosures – Flat Cover Application The quick release latch fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed for use as a terminal wiring box, instrumentation housing or electrical control enclosure where a hinged cover is desired. 2A–11 Construction The quick release latch enclosures are constructed of compression molded, fiberglass reinforced polyester. Enclosure includes a stainless steel continuous hinge and stainless steel quick release latches with padlock hasps. The cover gasket is a continuous urethane material. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.080” or 0.090” aluminum. Standards All flat cover quick release latch fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 35 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 36 NEMA Type 4X Quick Release Latch Fiberglass Enclosures – Flat Cover MOUNTING PANEL (ORDER SEPARATELY) Ø.31 (4) PLACES N H A 2A–12 M C W Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-060604CHQR 7.50 x 7.50 x 4.75 5.72 x 5.72 x 4.45 N4X-FG-080604CHQR 9.62 x 7.50 x 4.74 N4X-FG-100804CHQR D P B M Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 6.75 4.00 4.00 3 BP66A 4.88 x 4.88 7.73 x 5.74 x 4.45 8.88 4.00 4.00 4 BP86A 6.88 x 4.88 11.62 x 9.41 x 4.25 9.73 x 7.73 x 3.98 10.75 6.00 3.50 5 BP108A 8.88 x 6.88 N4X-FG-121005CHQR 13.56 x 11.43 x 5.21 11.79 x 9.80 x 4.94 12.75 8.00 4.50 7 BP1210A 10.88 x 8.88 N4X-FG-141206CHQR 15.50 x 13.50 x 6.25 13.53 x 11.55 x 5.94 14.62 10.00 5.37 9 BP1412A 12.88 x 10.90 N4X-FG-161406CHQR 17.53 x 15.46 x 6.73 15.63 x 13.60 x 5.94 16.75 12.00 5.36 12 BP1614A 14.88 x 12.90 N4X-FG-181608CHQR 19.62 x 17.61 x 8.82 17.69 x 15.69 x 8.45 18.88 12.00 7.99 19 BP1816A 16.88 x 14.90 N4X-FG-201608CHQR 22.00 x 17.68 x 8.83 19.72 x 15.72 x 8.45 21.25 10.00 8.00 21 BP2016A 17.00 x 13.00 All dimensions in inches 36 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 37 NEMA Type 4X Twist Latch Fiberglass Enclosures – Flat Cover Application The twist latch fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed for use as a terminal wiring box, instrumentation housing or electrical control enclosure where a hinged cover is desired. 2A–13 Construction The twist latch enclosures are constructed of compression molded, fiberglass reinforced polyester. Enclosure includes a stainless steel continuous hinge and stainless steel twist latches. The cover gasket is a continuous urethane material. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.080” or 0.090” aluminum. Standards All flat cover twist latch fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 37 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 38 NEMA Type 4X Twist Latch Fiberglass Enclosures – Flat Cover MOUNTING PANEL (ORDER SEPARATELY) Ø.31 (4) PLACES N C A H M 2A–14 W Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-060604CHTL 7.50 x 7.50 x 4.75 5.72 x 5.72 x 4.45 N4X-FG-080604CHTL 9.62 x 7.50 x 4.74 N4X-FG-100804CHTL D P B M Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 6.75 4.00 4.00 3 BP66A 4.88 x 4.88 7.73 x 5.74 x 4.45 8.88 4.00 4.00 4 BP86A 6.88 x 4.88 11.62 x 9.41 x 4.25 9.73 x 7.73 x 3.98 10.75 6.00 3.50 5 BP108A 8.88 x 6.88 N4X-FG-121005CHTL 13.56 x 11.43 x 5.21 11.79 x 9.80 x 4.94 12.75 8.00 4.50 7 BP1210A 10.88 x 8.88 N4X-FG-141206CHTL 15.50 x 13.50 x 6.25 13.53 x 11.55 x 5.94 14.62 10.00 5.37 9 BP1412A 12.88 x 10.90 N4X-FG-161406CHTL 17.53 x 15.46 x 6.23 15.63 x 13.60 x 5.94 16.75 12.00 5.36 12 BP1614A 14.88 x 12.90 N4X-FG-181608CHTL 19.62 x 17.61 x 8.82 17.69 x 15.69 x 8.45 18.88 12.00 7.99 19 BP1816A 16.88 x 14.99 N4X-FG-201608CHTL 22.00 x 17.68 x 8.83 19.72 x 15.72 x 8.45 21.25 10.00 8.00 21 BP2016A 17.00 x 13.00 All dimensions in inches 38 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 39 NEMA Type 4X Raised Cover Fiberglass Enclosures – Quick Release Latch Application 2A–15 The raised cover quick release latch fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed for use as a terminal wiring box, instrumentation housing or electrical control enclosure where a hinged cover is desired. It is also designed for use when components require additional depth. Construction The raised cover quick release latch enclosures are constructed of compression molded, fiberglass reinforced polyester. Enclosure includes a stainless steel continuous hinge and stainless steel quick release latches with padlock hasps. The cover gasket is a continuous urethane material. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.080” or 0.090” aluminum. Standards All raised cover quick release latch fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 39 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 40 NEMA Type 4X Raised Cover Fiberglass Enclosures – Quick Release Latch MOUNTING PANEL (ORDER SEPARATELY) Ø.31 (4) PLACES C H M 2A–16 A N W D P B Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-080606RCHQR 9.62 x 7.46 x 6.22 7.73 x 5.74 x 5.95 N4X-FG-100806RCHQR 11.62 x 9.37 x 6.61 N4X-FG-121006RCHQR M Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 8.88 4.00 5.49 4 BP86A 6.88 x 4.88 9.73 x 7.73 x 6.36 10.75 6.00 5.91 5 BP108A 8.88 x 6.88 13.56 x 11.43 x 6.61 11.79 x 9.80 x 6.32 12.75 8.00 5.87 7 BP1210A 10.88 x 8.88 N4X-FG-141207RCHQR 15.50 x 13.38 x 7.69 13.53 x 11.55 x 7.45 14.62 10.00 6.87 9 BP1412A 12.88 x 10.90 N4X-FG-161407RCHQR 17.53 x 15.43 x 7.71 15.63 x 13.60 x 7.45 16.75 12.00 6.87 12 BP1614A 14.88 x 12.90 N4X-FG-181610RCHQR 19.62 x 17.48 x 10.62 17.69 x 15.69 x 10.31 18.88 12.00 9.86 19 BP1816A 16.88 x 14.90 N4X-FG-201610RCHQR 22.00 x 17.56 x 10.64 19.72 x 15.72 x 10.33 21.25 10.00 9.87 21 BP2016A 17.00 x 13.00 All dimensions in inches 40 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 41 NEMA Type 4X Raised Cover Fiberglass Enclosures – Twist Latch Application 2A–17 The raised cover twist latch fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed for use as a terminal wiring box, instrumentation housing or electrical control enclosure where a hinged cover is desired. It is also designed for use when components require additional depth. Construction The raised cover twist latch enclosures are constructed of compression molded, fiberglass reinforced polyester. Enclosure includes a stainless steel continuous hinge and stainless steel twist latches. The cover gasket is a continuous urethane material. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.080” or 0.090” aluminum. Standards All raised cover twist latch fiberglass enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant), Type 12 (Dust-tight) and Type 6P (Prolonged Submersion in Water). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 41 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 42 NEMA Type 4X Raised Cover Fiberglass Enclosures – Twist Latch MOUNTING PANEL (ORDER SEPARATELY) Ø.31 (4) PLACES N C A H M 2A–18 W Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-100806RCHTL 11.62 x 9.37 x 6.61 9.73 x 7.73 x 6.36 N4X-FG-121006RCHTL 13.56 x 11.43 x 6.61 N4X-FG-141207RCHTL D P B M Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 10.75 6.00 5.91 5 BP108A 8.88 x 6.88 11.79 x 9.80 x 6.32 12.75 8.00 5.87 7 BP1210A 10.88 x 8.88 15.50 x 13.38 x 7.69 13.53 x 11.55 x 7.45 14.62 10.00 6.87 9 BP1412A 12.88 x 10.90 N4X-FG-161407RCHTL 17.53 x 15.43 x 7.71 15.63 x 13.60 x 7.45 16.75 12.00 6.87 12 BP1614A 14.88 x 12.90 N4X-FG-181610RCHTL 19.62 x 17.48 x 10.62 17.69 x 15.69 x 10.31 18.88 12.00 9.86 19 BP1816A 16.88 x 14.90 All dimensions in inches 42 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 43 NEMA Type 4X Large Control Fiberglass Enclosures Application The large control fiberglass enclosure can be used indoors or outdoors to provide protection against dust, dirt, oil and water. It is designed to house items such as electronic or electrical controls, instrumentation systems and mechanical controls. 2A–19 Construction The large control enclosures are constructed of compression molded, fiberglass reinforced polyester. Enclosure includes a stainless steel continuous hinge and stainless steel twist latches. A padlock hasp is also included. The cover gasket is a continuous urethane material. Panel mounting inserts are molded to interior of enclosure. External mounting feet are also molded to enclosure. Machine tool gray color. Panels Optional panels are available. Panels fabricated of 0.090” or 0.130” aluminum. Standards All large control enclosures conform to the National Electrical Manufacturers Association (NEMA) standard for Type 3 (Dust-tight, Raintight and Sleet/Ice Resistant), Type 4X (Watertight, Dust-tight and Corrosion Resistant) and Type 12 (Dust-tight). They are listed by Underwriters Laboratories, Inc. (UL) for Canada and the United States. Special Orders Custom units with holes punched and operators installed can be supplied. 43 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.2 12/9/01 10:41 AM Page 44 NEMA Type 4X Large Control Fiberglass Enclosures N A M 2A–20 H C Ø.50 (4) PLACES P D B W Catalog No. Overall Dimensions (in) AxBxC Inside Dimensions (in) HxWxD N4X-FG-201606CH 22.75 x 16.87 x 7.77 19.70 x 16.04 x 7.24 N4X-FG-201608CH 22.75 x 16.87 x 9.77 N4X-FG-201612CH M Mounting Dim. (in) N P Weight (lbs) Panel Catalog No. Panel Size (in) 21.50 10.12 6.26 17 BPN2016A 17.00 x 13.00 19.70 x 16.04 x 9.24 21.50 10.12 8.26 22 BPN2016A 17.00 x 13.00 22.75 x 16.87 x 13.77 19.70 x 16.04 x 13.24 21.50 10.12 12.26 24 BPN2016A 17.00 x 13.00 N4X-FG-242008CH 27.00 x 21.24 x 9.90 24.05 x 20.39 x 9.25 25.75 14.00 8.25 32 BP2420A 21.00 x 17.00 N4X-FG-242410CH 27.00 x 25.24 x 11.90 24.05 x 24.39 x 11.25 25.75 17.87 10.25 42 BP2424A 21.00 x 21.00 N4X-FG-302410CH 33.41 x 26.32 x 11.95 30.46 x 25.47 x 11.27 32.25 18.50 10.27 50 BP3024A 27.00 x 21.00 N4X-FG-302412CH 33.41 x 26.32 x 13.79 30.46 x 25.47 x 13.10 32.25 18.50 12.10 54 BP3024A 27.00 x 21.00 N4X-FG-363010CH 39.31 x 32.50 x 12.05 36.31 x 31.69 x 11.36 38.13 23.88 10.36 78 BP3630A 33.00 x 27.00 N4X-FG-363012CH 39.31 x 32.50 x 14.05 36.31 x 31.69 x 13.36 38.13 23.88 12.36 81 BP3630A 33.00 x 27.00 N4X-FG-483616CH 51.29 x 36.62 x 17.93 48.33 x 36.22 x 17.25 50.12 29.25 16.25 108 BP4836A 45.00 x 33.00 All dimensions in inches 44 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 45 Adalet Increased Safety Enclosures Increased Safety ‘e’ • Terminal Enclosures (TN, TSC & TFG Series) • High Voltage Junction Boxes (HV Series) • Control Panel Assemblies (CN Series) • Intrinsically Safe Terminal Enclosures (TSC & TFG Series) Increased Safety/Flameproof ‘ed’ • Control Panel Assemblies (CN Series) TN4 Series: Single Door Clamped Terminal Enclosures. 14-gauge materials: TN4 steel powder coated; TN4X stainless steel 304; TN4X6 stainless steel 316L. TN4 Expanded Series: Single Door Clamped Terminal Enclosures. 3A–1 TSC Series: Screw Cover Terminal Enclosures. 14-gauge materials: TSC4 steel powder coated; TSC4X stainless steel 304; TSC4X6 stainless steel 316L. CN4 Series: Control Panel Enclosure. 14-gauge materials: CN4 steel powder coated; CN4X stainless steel 304; CN4X6 stainless steel 316L. TFG Series: Fiberglass Terminal Enclosures HV Series: High Voltage Junction Boxes. 14-gauge materials: HV4 steel powder coated; HV4X stainless steel 304; HV4X6 stainless steel 316L. 45 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 46 Adalet Increased Safety Enclosures Increased Safety Enclosures These enclosures provide an alternative to flameproof enclosures and are commonly made from sheet steel, fiberglass, and die cast aluminum. They are intended to house electrical equipment that will not generate an arc or spark during normal operation. Additional design measures are taken to prevent the possibility of excessive heat, the ingress of water or dust, and the resistance to impact, thus preventing any explosions from occurring. • Temperatures: of parts of equipment must be limited so as not to exceed values which would affect the thermal stability of the material and the T-Class relating to the ignition of explosive atmospheres. Areas of Use Zone Classified Areas – U.S., Canada, Europe Zones 1 and 2 3A–2 Principle ATEX – EU Directive 94/9/EC – Europe Intended for product in which arcs and sparks do not occur in normal service not under fault conditions and in which surface temperatures are controlled below incendive values. Increased Safety is achieved by enhancing insulation values and creepage and clearance distances above those required for normal service, thus providing a safety factor against accidental breakdown. Increased Safety must not be confused with Intrinsically Safe; they are two completely different approaches. Intrinsic Safety requires that the electrical components within an enclosure have very low levels of electrical energy, either stored or circulating. Typically, allowable currents will be in the tens of milliamperes and voltage will be less than 100 volts, so they will be insufficient to ignite a surrounding explosive atmosphere even under fault conditions. Equipment Groups II Equipment Category 2GD Applicable Standards Europe: EN50014, EN50019 U.S.: UL2279 pt 7 Canada: CSA-E79-0, CSA-E79-7 International: IEC 60079-0, IEC 60079-7 Typical Testing for Increased Safety Apparatus • Thermal conditioning test Key Design Features • Enclosure: must be constructed to withstand mechanical impact and provide a specified degree of ingress protection (IP rating). A minimum IP54 rating is required for Increased Safety enclosures. • Mechanical strength • Temperature rise • Ingress Protection (IP Rating) • Electrical Strength • Thermal Stability of Insulating Materials • Terminals for external connections: must be generously dimensioned for the intended connection and ensure that conductors are securely fastened. • Internal connections: must not be subject to undue mechanical stress and shall be made using specified methods. • Clearances: between bare conductive parts must not be less than the values specified according to the rated voltage. • Creepage distances: must not be less than the values specified according to the rated voltage and the Comparative Tracking Index (CTI) of the insulating material. 46 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 47 Hazardous Location Marking National Electrical Code Article 505 Note 1: Products approved for use in areas classified under Article 505 could only be used in this area. Products approved for use in areas classified under Article 500 are allowed to be installed in Article 505 areas, except Zone 0. Article 505 was first introduced in the 1996 National Electrical Code. This new Article offered an alternative to the classification of hazardous locations based on the standards for area classification by the International Electrotechnical Commission (IEC). With the introduction of this new Article, engineers could now classify hazardous locations using either Article 500 or Article 505. Note 2: The IEC Classification scheme also addresses underground mines. Article 505 does not address this area classification. All mines in the United States fall under the jurisdiction of the Mine Safety and Health Administration (MSHA). In 1999, further revision to this Article continued to bring it closer to the IEC 79 series. The 1999 changes introduced: 1. the eight different Protection Methods used by IEC, 2. the inclusion of metric threaded holes, and 3. special precautions involving area classification, dual classification, and the reclassification of division classified areas. Compliance to American (United States) Standards Area Classification 3A–3 Equipment Marking Ambient Temperature Range in Service (other than –20°C to +40°C) Class I, Zone 1, AEx ed IIC T5 Tamb -40°C to +50°C IP66 Zone 0 Continuous Hazard Zone 1 Intermittent Hazard Zone 2 Hazard Under Abnormal Conditions For use in Explosive Atmosphere Temperature Classification Protection Method (main concept appears first) m Encapsulation (Zone 1) T class Max Surface Temp T1 ≤450°C T2 ≤300°C T3 ≤ 200°C T4 ≤135°C T5 ≤ 100°C T6 ≤ 85°C d Flameproof (Zone 1) e Increased Safety (Zone 1) Gas Grouping Ingress Protection i* Intrinsically Safe (Zone 0/1) I Methane (firedamp) IP0x No Protection IPx0 No Protection IP1x Objects >50mm IPx1 Vertically dripping water o Oil Immersion (Zone 1) p Pressurized (Zone 1) (Mining Only) IIA Propane IP2x Objects >12mm IPx2 75° to 90° dripping water q Powder Filling (Zone 1) IIB Ethylene IP3x Objects >2.5mm IPx3 Sprayed water n* Non-Sparking (Zone 2) IIC Acetylene/Hydrogen IP4x Objects >1mm IPx4 Splashed water IIB+H2 Hydrogen IP5x Dust protected IPx5 Water jets II All Gases IP6x Dust-tight IPx6 Heavy seas *denotes additional sub-categories IPx7 Effects of immersion IPx8 Indefinite immersion 47 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 48 Hazardous Location Marking CENELEC The Conformity Mark CENELEC is the European Committee for Electrotechnical Standardization. It was established in 1973 as a non-profit organization under Belgium Law. Under the Explosive Atmospheres and Gassy Mines Directive (79/117/EEC), the “Epsilion x” symbol indicates conformity with the CENELEC requirements. This symbol is only allowed to be applied to products which are considered to be final assemblies. Not empty enclosures or component parts. The European Commission under Directive 83/189/EEC has officially recognized it as the European Standards Organization in its field. Each member country typically has at least one recognized test agency or notified body. These members have been working together in the interest of European harmonization since the late fifties, developing alongside the European Economic Community. CENELEC works with 35,000 technical experts from 19 countries to publish standards for the European market. 3A–4 Equipment Marking Ambient Temperature Range in Service (other than –20°C to +40°C) Compliance to European Harmonized Standard EEx ed IIC T5 Tamb -40°C to +50°C IP66 For use in Explosive Atmosphere Temperature Classification Protection Method (main concept appears first) m Encapsulation (Zone 1) T class Max Surface Temp T1 ≤450°C T2 ≤300°C T3 ≤ 200°C T4 ≤135°C T5 ≤ 100°C T6 ≤ 85°C d Flameproof (Zone 1) e Increased Safety (Zone 1) Gas Grouping Ingress Protection i* Intrinsically Safe (Zone 0/1) I Methane (firedamp) IP0x No Protection IPx0 No Protection IP1x Objects >50mm IPx1 Vertically dripping water IPx2 75° to 90° dripping water o Oil Immersion (Zone 1) (Mining Only) p Pressurized (Zone 1) IIA Propane IP2x Objects >12mm q Powder Filling (Zone 1) IIB Ethylene IP3x Objects >2.5mm IPx3 Sprayed water n* Non-Sparking (Zone 2) IIC Acetylene/Hydrogen IP4x Objects >1mm IPx4 Splashed water *denotes additional sub-categories IIB+H2 Hydrogen IP5x Dust protected IPx5 Water jets II All Gases IP6x Dust-tight IPx6 Heavy seas IPx7 Effects of immersion IPx8 Indefinite immersion 48 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 49 Hazardous Location Marking ATEX Directive The New Conformity Mark The ATEX Directive 94/9/EC was adopted by the European Union (EU) to facilitate free trade in the EU by aligning the technical and legal requirements in the Member States for products intended for use in potentially explosive atmospheres. Under the old Explosive Atmospheres and Gassy Mines Directive (79/117/EEC), the “Epsilion x” symbol indicated conformity with the CENELEC requirements. This symbol was allowed to be applied to products which were considered to be final assemblies. Not empty enclosures or component parts such as terminal blocks, operators, breather drains, plugs, etc.. The “Epsilion x” symbol will move into the marking string and be used to indicate explosion protection. The ATEX Directive went into affect (on a voluntary basis) on March 1, 1996. This Directive will become mandatory effective on July 1, 2003. All Product intended for use in explosive atmospheres must comply with this Directive in order to be sold or placed in service in any Member State of the European Union. Under the New Directive, the “CE” mark will now indicate conformity to the ATEX Directive. This mark can only be placed on final assemblies and not to empty enclosures or component parts. 0539 3A–5 Equipment Marking II 1 G CE Conformity Marking Type of Explosive Atmosphere G Gas/Vapor/Mist (Zone 0, 2, 2) Identification Number of the notified body D Dust (Zone 20, 21, 22) (i.e. DEMKO) Equipment Category (Mining) EU Explosive Protection Symbol M1 Energized Equipment Group M2 De-energized I Mining (Non-Mining) II Non-Mining 1 Very High Protection (Zone 0 & 20) 2 High Protection (Zone 1 & 21) 3 Normal Protection (Zone 2 & 22) 49 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 50 Selecting An Increased Safety Terminal Enclosure Overview Following the steps outlined below will guide you in selecting the appropriate enclosure for your Increased Safety application. Adherence to these Steps will ensure that the enclosure you select will meet the requirements for Increased Safety Certification. STEPS: STEP 2: Select a Terminal Block Manufacturer and Terminal Block Adalet Enclosures can utilize various manufacturers of Terminal Blocks, select from: • Entrelec • Phoenix • Wago 1. Select the Enclosure Series and Catalog Prefix. • Weidmuller 2. Select a Terminal Block Manufacturer and Terminal Block. • Wieland 3. Determine the Enclosure Size and Catalog Number. 4. Locate the Thermal Dissipation Chart for the Enclosure you selected. • Woretz • Consult factory for others. Beginning on the fourth page of each Enclosure Series Section, you will find Tables for each of the above Terminal Block Manufacturers. Select a Manufacturer and a Terminal Block for your application. 5. Select the Wire Size for your Application. 6. Select the Current to be applied to the Wire. STEP 1: Select the Enclosure Series and Catalog Prefix 3A–6 Select an Enclosure Series based on the environmental needs of your application from these options: TN Single Door Clamped Series: If you have no preference for a specific Terminal Block Manufacturer, use the Quick Selector found on the third page of the Enclosure Section. Select the Wire size for your application and Adalet will supply a suitable Terminal Block. TN4 – Steel Powder Coated STEP 3: Determine the Enclosure Size and Catalog Number TN4X – Stainless Steel 304 TN4X6 – Stainless Steel 316L From the table selected in Step 2, the quantities that are shown under a terminal block type indicates the maximum number of terminal blocks for each enclosure size. (Warning: These quantities may not qualify the Enclosure for an Increased Safety Certification.) The column to the far left indicates the catalog enclosure size. NOTE: This is also the nominal outside dimension of the enclosure (i.e. –201407: 20” length x 14” width x 07” depth). TSC Screw Cover Series: TSC4 – Steel Powder Coated TSCX – Stainless Steel 304 TSC4X6 – Stainless Steel 316L TFG Screw Cover Series: TFG – Fiberglass Reinforced Polyester Use the following steps: For the Terminal Block Type selected, follow the column down until the quantity meets or exceeds your requirement. Then follow the row to the far left to find the catalog enclosure size. If your quantity requirement is not met, select another Terminal Block Type (most manufacturers build various sizes of terminal blocks of the same wire size) or select another Enclosure Series. NOTE: You might want to consider having a few extra Terminal Blocks for future expansion. 50 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 51 Selecting An Increased Safety Terminal Enclosure IF THE TERMINAL BLOCK QUANTITY DOES NOT MEET THE NEEDS OF YOUR APPLICATION, CONTINUE WITH THE FOLLOWING STEPS STEP 4: Locate the Thermal Dissipation Chart for the Enclosure you selected. Each enclosure size has a unique Thermal Dissipation Chart used to qualify for Increased Safety Certification. These charts can be found on the catalog page of the enclosure style you selected. For quick reference, the catalog page number is located in the column next to each enclosure size in the Terminal Block Content tables used in Step 3. STEP A: Reduce the Current for your Application Follow the Conductor Cross Section column up until you find the Terminal Count required for you application. Follow the row across to the left to find the maximum allowable Current. STEP 5: Select the Wire Size for your Application IF THE CURRENT CANNOT BE REDUCED OR IS LESS THAN WHAT IS REQUIRED, CONTINUE WITH STEPS B OR C. On the Thermal Dissipation Chart, locate the row listing Conductor Cross Section. Follow the row across until you find the wire size that will be connected to the terminal block. NOTE: typically, a terminal block catalog number indicates the maximum wire size that can be installed. STEP B: Increase the Wire Size for your Application On the Thermal Dissipation Chart, locate the column for Current. Follow the column down until you find the current that will be applied to the conductor. At the intersection of the Current row and Conductor Cross Section column from Step 5, you will find the maximum number of terminal blocks allowed in the enclosure for an Increased Safety Certification. 3A–7 STEP 6: Select the Current to be Applied to the Wire Determine if you can use a larger conductor size. If you selected a 1.5mm2 conductor for a terminal block that will accommodate a 2.5mm2 conductor, increase the Conductor Size. This will increase the terminal block quantity. Find the required quantity in the new Conductor Cross Section column. Follow that row across to the left, this is the new maximum Current. IF THE CURRENT IS STILL LESS THAN REQUIRED, CONTINUE TO STEP C. If this meets your requirements, you are done. STEP C: Select a Larger Size Enclosure If neither the current or the conductor size can be changed. Select the next size enclosure and repeat STEP 4-6. If none of these Steps provides you with the necessary terminal block or current, you might consider another Enclosure Series, or consult Factory. 51 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 52 Increased Safety Enclosure Selection Examples Enclosure Selection: Example 1 Enclosure Selection: Example 2 A customer requires a TSC4X-080804 Enclosure with (19) Weidmuller SAK2.5 terminal blocks installed. A customer can only fit a TSC4X-121206 Enclosure within their skid package. They want (30) Weidmuller SAK2.5 terminal blocks installed and they would like 16 Amps with 2.5mm2 conductors. No information on Current or Conductor Size is given. Question: Will (19) SAK2.5 terminal blocks fit in the enclosure? Question: Will the enclosure qualify for Increased Safety Certification? SAK6N Answer: Yes, from the chart above (19) SAK2.5 terminal blocks will fit. SAK4 Chart reduced for clarity SAK2.5 5 8 11 28 40 40 27 27 AKE4 6 10 14 17 50 50 33 33 AKE2.5 6 11 15 19 54 54 36 36 Cat. Page SAK6N 6 9 13 34 72 72 31 31 Enclosure Size SAK4 7 12 34 46 99 99 43 43 SAK2.5 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 AKE4 -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 Question: Can (30) SAK2.5 terminal blocks fit in a TSC4X-121206 enclosure? Locate the Maximum Physical Content Chart for Weidmuller in the TSC Section. AKE2.5 Cat. Page 3A–8 Enclosure Size Locate the Maximum Physical Content Chart for Weidmuller in the TSC Section. -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 7 12 34 46 99 99 43 43 86 86 172 172 6 9 13 34 72 72 31 31 62 62 93 93 6 11 15 19 54 54 36 36 36 36 108 108 6 10 14 17 50 50 33 33 33 33 99 99 5 8 11 28 40 40 27 27 54 54 81 81 Chart reduced for clarity Locate the Thermal Dissipation Chart for the 080804 enclosure. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 55 #### #### #### #### #### Maximum fill permitted based solely 10 27 #### #### #### #### on minimum #### wire bending space 16 9 17 69 ####and electrical #### clearances#### 20 3 10 20 #### #### #### 25 #### 5 11 22 #### #### 35 #### testing required, #### 3 8 21 #### Additional Consult Factory 50 #### #### #### 1 7 17 Answer: Yes, (19) SAK2.5 terminal blocks can be installed and Increased Safety Certification given with a maximum current of 10 Amps using 2.5mm2 wires. Important: The Maximum Amperage and Conductor Size has to be forwarded to the customer. Answer: Yes, from the chart above the -121206 can fit (108) terminal blocks. Question: Will the enclosure qualify for Increased Safety Certification? Locate the Thermal Dissipation Chart for the 121206 enclosure. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 85 #### #### #### #### #### Maximum fill permitted based solely 10 41 #### #### #### #### on minimum #### wire bending space 16 14 27 107 ####and electrical #### clearances#### 20 5 16 31 #### #### #### 25 #### 7 17 33 #### #### 35 #### testing required, #### 5 13 33 #### Additional Consult Factory 50 #### #### #### 1 10 27 Answer: No, from the chart above the -121206 can fit (27) terminal blocks at 16 Amps with 2.5mm2 wire 52 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 53 Increased Safety Enclosure Selection Examples Enclosure Selection: Example 2 Cont. Question: Will the enclosure qualify for Increased Safety Certification? Question: What STEPS can you take. Locate the Thermal Dissipation Chart for the 121206 enclosure. Reminder: They can only use a –121206 enclosure. Option 1: STEP A – Reduce the Current to be applied to Wire Question: Will the customer accept a lower amperage? Locate the Thermal Dissipation Chart for the 121206 enclosure. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 85 #### #### #### #### #### Maximum fill permitted based solely 10 41 #### #### #### #### on minimum #### wire bending space 16 14 27 107 ####and electrical #### clearances#### 20 5 16 31 #### #### #### 25 #### 7 17 33 #### #### 35 #### testing required, #### 5 13 33 #### Additional Consult Factory 50 #### #### #### 1 10 27 Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 85 #### #### #### #### #### Maximum fill permitted based solely 10 41 #### #### #### #### on minimum #### wire bending space 16 14 27 107 #### and electrical #### clearances#### 20 5 16 31 #### #### #### 25 #### 7 17 33 #### #### 35 #### testing #### 5 13 33 #### Additional required, Consult Factory 50 #### #### #### 1 10 27 Answer: Yes, (30) SAK4 terminal blocks can be installed and Increased Safety Certification given with a maximum current of 16 Amps using 4mm2 wires. 3A–9 Answer: Reducing the Current to 10 Amps allows the customer to stay in the –121206 Enclosure with (30) SAK2.5 terminal blocks while qualifying the enclosure for Increased Safety Certification. Option 2: STEP B – Increase the Wire Size Note: Increasing the conductor size will change the terminal block size and may affect the enclosure size. Question 1: Will the customer change wire size and terminal block size? Question 2: Will (30) SAK4 terminal block fit in the -121206 enclosure? SAK2.5 SAK4 SAK6N 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 AKE4 Cat. Page -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 AKE2.5 Enclosure Size Locate the Maximum Physical Content Chart for Weidmuller in the TSC Section. 7 12 34 46 99 99 43 43 86 86 172 172 6 9 13 34 72 72 31 31 62 62 93 93 6 11 15 19 54 54 36 36 36 36 108 108 6 10 14 17 50 50 33 33 33 33 99 99 5 8 11 28 40 40 27 27 54 54 81 81 Answer: Yes, from the chart above (30) SAK4 Terminal Blocks will fit. 53 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 A 12/9/01 10:43 AM Page 54 Increased Safety Enclosure Selection Examples Enclosure Selection: Example 3 Question: What STEP must you take? Reminder: The current is 16 Amps minimum with 2.5mm2 wire A customer requires a TSC Series Enclosure with (30) Weidmuller SAK2.5 terminal blocks installed. The Minimum Current is 16 Amps with 2.5mm2 conductors. Answer: STEP C - Select a Larger Enclosure 5 8 11 28 40 40 27 27 SAK6N 6 10 14 17 50 50 33 33 SAK4 6 11 15 19 54 54 36 36 SAK2.5 SAK6N 6 9 13 34 72 72 31 31 AKE4 SAK4 7 12 34 46 99 99 43 43 AKE2.5 SAK2.5 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 AKE4 -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 AKE2.5 Cat. Page 3A–10 Enclosure Size Locate the Maximum Physical Content Chart for Weidmuller in the TSC Section. Cat. Page Question: What is the smallest enclosure that can fit (30) SAK2.5 terminal blocks? Enclosure Size Locate the Maximum Physical Content Chart for Weidmuller in the TSC Section. -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 7 12 34 46 99 99 43 43 6 9 13 34 72 72 31 31 6 11 15 19 54 54 36 36 6 10 14 17 50 50 33 33 5 8 11 28 40 40 27 27 Chart reduced for clarity Question: Will this enclosure qualify for Increased Safety Certification? Chart reduced for clarity Locate the Thermal Dissipation Chart for the 101008 enclosure. Answer: From the chart above the smallest enclosure –101006 can fit (54) terminal blocks. Question: Will the enclosure qualify for Increased Safety Certification? Locate the Thermal Dissipation Chart for the 101006 enclosure. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 77 #### #### #### #### #### Maximum fill permitted based solely 10 37 #### #### #### #### on minimum #### wire bending space 16 13 25 97 ####and electrical #### clearances#### 20 5 14 28 #### #### #### 25 #### 7 16 30 #### #### 35 #### testing required, #### 4 12 30 #### Additional Consult Factory 50 #### #### #### 1 9 24 Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 92 #### #### #### #### #### Maximum fill permitted based solely 10 45 #### #### #### #### on minimum #### wire bending space 16 15 30 116 ####and electrical #### clearances#### 20 6 17 33 #### #### #### 25 #### 8 19 36 #### #### 35 #### testing required, #### 5 14 35 #### Additional Consult Factory 50 #### #### #### 2 11 29 Answer: YES. The TSC Series –101008 enclosure with (30) SAK2.5 terminal blocks will qualify for Increased Safety Certification at 16 Amps with 2.5mm2 conductors. Answer: The terminal block quantity does not meet the customer’s requirement for (30) terminal blocks. 54 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 55 TN4 Series - Single Door Clamped Style Options Gland Plates These removable plates offer great flexibility for the end user to drill holes without having to remove the entire enclosure from the installation site. Add the following Suffixes: -A: Gland Plate installed on top of box. -B: Gland Plate installed on bottom of box. -C: Gland Plate installed on left of box. -D: Gland Plate installed on right of box. For multiple gland plates omit dashes (i.e. TN4X-201407-ABCD). Note that sizes 251807, 302207, 362507 and 392907 are furnished standard with multiple gland plates. Conduit/Cable Entries: 3B–1 Entries can be provided per a customer sketch or with detailed information on the entry locations. Please refer to Entry Spacing Tables at the end of the Increased Safety Section in the CENELEC Product Catalog. Note: This information is important and could affect the size of the enclosure you selected. Close-up Plugs: 85 Enclosure Sizes Available in 85 sizes, from 16”x12”x6” (model 161206) to 60”x36”x12” (model 603612). Any unused entries must be plugged with a Certified Close-Up Plug. Adalet can provide close-up plugs in various styles and materials. Please indicate on the sketch or provide detailed information of holes to be plugged. Enclosure Labeling: Construction • Available in (3) Materials: SS304, SS316L, PowderCoated (ASA61 Grey) Steel. • Folded Lip around the Door Opening to provide complete and maximum gasket seal. • Continuously Welded and Ground Smooth Seams. • Continuous One-Piece Silicone Gasket (sizes 2014, 2518, 3022, 3625, 3929). • Silicone Strip Gasket For All Other Sizes. • Welded on External Mounting Feet with 5/16” Clearance Holes/Slot. • External Door Clamps. • Continuous Piano Type Hinge with Removable SS Hinge Pin. Adalet can provide additional enclosure labeling with custom silk screening or various colors of Lamacoid™ nameplates. Please provide detailed information of the logo or text required. Breather Drains: Breather Drains can be provided per customer request. They are available in Brass or Stainless Steel 316L. Please indicate on a sketch or provide detailed information for locations. Grounding Busbars: Some applications might require grounding points to be terminated in the enclosure. With the use of a Ground Busbar System this can be accomplished, consult factory for options. Mounting Pans: • Internal/External Earthing Stud. As an alternative to the universal rail mounting system, mounting pans are available in steel/powder coated, stainless steel, and aluminum. Please indicate when requesting quote. • Universal Rail Mounting System. Terminal Strip Assemblies: • Padlock Hasp & Staple for Padlocking. Various options (i.e. marking tags, protective covers, jumpers, partitions, etc.) are available. Please provide detailed information requesting quote. • Ground Studs on Box and Cover. 55 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 56 TN4 Series - Single Door Clamped Style General Information Adalet's Single Door Clamped Terminal Enclosures are available in Stainless Steel 316L & 304 and Carbon Steel. Adalet can also supply custom size enclosures, operators, and components to suit your Increased Safety Application. Silicone gaskets, removable hinge pin, box & cover ground studs including an internal/external earthing stud, along with internal standoffs and universal rail mounting system are included as standard. Enclosure Certifications with Terminals 3B–2 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Empty Enclosure Certifications 0539 II 2GD EEx e II Ex e II Class I, Zone 1, AEx e II Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Working Voltage Terminal Blocks Various manufacturers Material TN4 Series TN4X Series TN4X6 Series TN4 Series Gland Plates TN4X Series Gland Plates TN4X6 Series Gland Plates Mounting Pan Gasket Cover Gland Plates Lid Fixing Hinge TN4 Series TN4X Series TN4X6 Series Door Clamps TN4 Series TN4X Series TN4X6 Series Enclosure Mounting All Types Gland Plate Hardware All Types Grounding Box & Cover All Types Earthing Stud All Types Impact Resistant All Types Ambient Temperature Range All Types ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 D ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 1100 Volts Maximum EEx e type with wire sizes 1.5mm up to 240mm #14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray #14ga Stainless Steel 304, Brushed Finish #14ga Stainless Steel 316, Brushed Finish #10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray #10ga Stainless Steel 304, Brushed Finish #10ga Stainless Steel 316, Brushed Finish #14ga Cold Rolled Steel, Polyster Powder Coated White Silicone Sponge Silicone Sponge Continuous piano type - Steel with removable SS304 pin Continuous piano type - SS304 with removable pin Continuous piano type - SS316 with removable pin Plated Steel Clear Stainless Steel 304 Stainless Steel 316 Four (4) external lugs with .44" clearance holes/slots 300 Series stainless steel 1/4-20 Stud with 300 series stainless steel hardware 1/4-20 Stud - All components brass 7 Nm to EN50014/EN50019 -40°C to +70°C to EN50014 D 56 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 57 TN4 Series - Quick Selector Enclosure Selection 1. Using the table below, select the terminal block size for your application. 2. Follow the column down until you find the quantity required for your application. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. For Increased Safety Applications 1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table. Maximum Physical Terminal Block Content 2.5mm 4mm 6mm 10mm 16mm 35mm 50mm 70mm 95mm 120mm 150mm 185mm 240mm -201407 3B–7 222 183 168 184 111 62 23 0 0 0 0 0 0 0 -251807 3B–8 500 410 380 305 200 126 31 25 22 10 0 0 0 0 -302207 3B–9 750 618 570 462 310 156 78 31 28 13 0 0 0 0 -362507 3B–10 1092 896 826 672 468 260 96 78 35 16 24 16 0 0 -392907 3B–11 1368 1120 1032 840 595 355 159 84 76 34 26 17 0 0 3B–3 TN4 Series Enclosure Catalog Sizes Page 1.5mm Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 2. Quantities shown above are for Adalet supplied standard terminal blocks. 57 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 58 Maximum Physical Terminal Block Content Enclosure Selection 1. Using the table below, select the terminal block type for your application. 2. Follow the column down until you find the quantity required for your application. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected. For Increased Safety Applications 1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table. 0 14 17 22 48 M1,5/6.HH MTC6 MA2,5/5.SNB M4/6.SN M4/6.SNB M6/8.SNB M4/8.SN 183 410 618 896 1128 183 410 618 896 1128 138 310 468 679 848 138 248 390 582 742 183 410 618 896 1128 183 410 618 896 1128 183 410 618 896 1128 138 310 468 679 848 138 310 468 679 848 M120/35 M70.31.AF 0 16 20 50 54 219 490 738 1071 1344 D6/8.ADO 14 38 48 90 99 183 410 618 896 1128 D6/8…ADO 0 0 15 18 20 183 328 515 768 987 D4/6.ADO 0 14 17 22 48 M35/26.AF M70/31.FF 0 16 20 50 54 183 328 515 768 987 D4/6.ADO.T 14 38 48 90 99 M4/6.H M35/16 248 498 728 1161 1420 0 22 28 35 76 M300/42.AF M16/12 23 31 78 96 159 M70/22 M10/10 62 123 208 256 355 M120/35.AF M6/8 111 196 310 462 595 M300/42.FF M4/6 138 310 468 679 848 M120/35.FF MA2,5/5.1 183 410 618 896 1128 M35/26.FF MA2,5/5 219 490 738 1071 1344 DR4/6 Cat. Page 3B–7 3B–8 3B–9 3B–10 3B–11 219 490 738 1071 1344 D4/6…ADO -201407 -251807 -302207 -362507 -392907 3B–7 3B–8 3B–9 3B–10 3B–11 0 0 0 0 20 0 14 17 22 48 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 62 126 156 260 355 23 31 78 96 159 0 22 28 35 76 12 16 20 50 56 12 16 20 50 56 12 16 20 50 56 WFF120 ZDU2.5 ZDU4 ZDU6 AKZ2.5 AKZ4 AKE2.5 305 486 816 1143 1540 296 594 875 1395 1700 0 14 18 23 50 0 14 18 23 50 0 14 18 23 50 0 10 13 16 34 SAKG 46 II 111 200 310 468 595 370 594 1000 1395 1870 SAKG 40 III 184 305 462 672 840 138 244 385 480 630 SAKG 40 II 168 380 570 826 1032 183 328 515 640 840 SAKG 40 I 183 410 618 896 1120 219 392 615 918 1176 SAKG 32 III 216 365 637 904 1125 0 0 0 18 19 SAKG 32 II 3B–7 3B–8 3B–9 3B–10 3B–11 0 0 19 23 25 SAKG 32 I -201407 -251807 -302207 -362507 -392907 WFF70 0 17 22 54 60 SAKG 28 III WWF35 0 0 0 24 26 SAKG 28 II WDU120 0 0 23 29 31 SAKG 28 I WDU70 23 31 78 96 106 SAK70 WDU35 62 84 156 260 284 SAK35N WDU16 74 150 252 390 516 SAK16 WDU10 141 252 395 594 756 SAK10 WDU6 222 400 625 936 1197 SAK6N WDU4 222 400 625 936 1197 SAK4 WDU2.5 222 500 750 1092 1368 SAK2.5 WDU2.5N 3B–7 3B–8 3B–9 3B–10 3B–11 AKE4 Cat. Page -201407 -251807 -302207 -362507 -392907 Cat. Page Enclosure Size Manufacturer - Weidmuller Enclosure Size 3B–4 Enclosure Size -201407 -251807 -302207 -362507 -392907 Cat. Page Enclosure Size Manufacturer - Entrelec 0 10 13 16 34 0 10 13 16 34 0 0 0 16 17 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 2. Weidmuller WFF Series are installed on a mounting pan. 58 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 59 Maximum Physical Terminal Block Content Enclosure Selection 1. Using the table below, select the terminal block type for your application. 2. Follow the column down until you find the quantity required for your application. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected. For Increased Safety Applications 1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table. 3424 gr 3425 gr 3426 gr 3427 gr 3428 gr 3429 gr 30841 grEx 30842 gr Ex 30843 gr Ex 30844 gr Ex 3468 gr Ex 3469 gr Ex 30111 gr 3301 gr 186 336 525 780 1144 141 248 390 582 856 82 168 280 435 570 68 90 171 284 390 26 35 90 110 122 0 21 27 34 74 90 160 300 434 544 78 136 215 324 413 44 90 114 188 260 18 24 60 74 123 0 18 22 56 60 0 0 18 23 25 186 336 630 910 1144 186 336 525 780 1144 Cat. Page 3302 gr 3303 gr 3304 gr 3305 gr 3306 gr 3712 gr Ex 3713 gr Ex 3713/16 gr Ex 3714 gr Ex 3715 gr Ex 3716 gr Ex 30831 gr Ex 30832 gr Ex 30833 gr Ex 30834 gr Ex -201407 -251807 -302207 -362507 -392907 3B–7 3B–8 3B–9 3B–10 3B–11 141 248 390 582 856 82 168 280 435 570 68 90 171 284 390 26 35 90 110 122 0 21 27 33 74 81 180 270 392 488 69 124 195 294 371 38 78 99 164 225 17 22 56 70 117 0 18 22 56 60 0 0 18 23 25 90 200 300 434 544 78 136 215 324 413 44 90 114 188 260 18 24 60 74 123 3B–5 30128 gr 3B–7 186 3B–8 336 3B–9 630 3B–10 910 3B–11 1144 Enclosure Size -201407 -251807 -302207 -362507 -392907 Cat. Page Enclosure Size Manufacturer - Woretz Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 59 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 60 Maximum Physical Terminal Block Content Enclosure Selection 1. Using the table below, select the terminal block type for your application. 2. Follow the column down until you find the quantity required for your application. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 4. To complete Catalog Number, refer to Catalog Page indicated next to Enclosure Size you selected. For Increased Safety Applications 1. Refer to Catalog Page indicated next to the Enclosure Size you selected for Heat Dissipation Table. ZFK 6 MBK 2,5/E-EX 300 486 808 1134 1518 ZFK 4 UKH 150 0 0 0 0 27 ZKF 2,5 UKH 95 0 20 25 31 68 ZFK 1,5 UKH 50 0 25 31 78 84 MZDB 1,5-NS 35 UK 35 24 33 82 102 168 MZDB 1,5 UK 16 N 60 123 204 256 350 MZB 1,5-NS 35 UK 10 N 108 196 305 456 588 MZB 1,5 UK 6 N 135 305 456 665 832 UK 3-RETURN UK 5 N 180 405 606 882 1104 180 216 305 384 532 720 760 900 936 1312 288 480 840 1200 1476 216 480 720 1050 1312 144 240 427 600 747 108 240 366 525 664 267 476 750 1116 1428 216 384 600 900 1148 180 324 505 756 966 135 183 304 475 624 MBK 6/E UK 3 N 216 480 720 1050 1312 Cat. Page -201407 3B–7 216 -251807 3B–8 480 -302207 3B–9 720 -362507 3B–10 1050 -392907 3B–11 1312 Enclosure Size UK 2,5 N Manufacturer - Phoenix 264-225 21 213 29 380 72 595 90 882 147 1134 264-125 283-691 62 126 156 260 355 264-220 284-691 74 150 252 390 510 264-120 282-691 141 252 390 490 642 281-693 281-991 183 324 510 756 973 280-698 281-691 183 324 510 756 966 285-691 280-991 Cat. Page Enclosure Size -201407 3B–7 213 -251807 3B–8 380 -302207 3B–9 595 -362507 3B–10 882 -392907 3B–11 1134 183 252 180 324 420 300 510 735 525 630 1040 744 973 1287 918 252 420 630 910 1287 148 250 378 546 765 WK 4/U WK 6/U WKI 35/U WKN 10/U WKN 16/U WKN 35/U WKN 70/U WKN 150/U -201407 3B–7 222 -251807 3B–8 495 -302207 3B–9 750 -362507 3B–10 1085 -392907 3B–11 1360 186 415 624 903 1136 138 248 468 582 848 37 49 124 154 170 74 147 248 385 510 62 82 156 256 284 23 31 39 96 106 0 20 26 32 70 0 0 0 27 30 Cat. Page WK 2.5/U Manufacturer - Wieland Enclosure Size 3B–6 Manufacturer - Wago Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 60 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 61 TN4 Series - Single Door Clamped 20''x 14''x 7'' SS316L Enclosures with Terminals CATALOG NUMBER TN4X6-201407 TN4X6-201407-A TN4X6-201407-B TN4X6-201407-C TN4X6-201407-D TN4X6-201407-AB TN4X6-201407-CD TN4X6-201407-ABCD GLAND PLATES NONE SIDE A SIDE B SIDE C SIDE D SIDE A & B SIDE C & D SIDE A, B, C, & D 1. For Stainless Steel 304 assemblies substitute TN4X6 prefix with TN4X. 2. For Steel Powder Coated assemblies substitute TN4X6 prefix with TN4. 3. For empty Enclosure add U immediately following enclosure size (i.e. TN4X6-201407U). Size NPT 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 3B–7 Gland Plate Entries Maximum Number of Entries Sides A & B Sides C & D 18 22 14 18 12 14 4 6 4 5 3 4 3 3 Metric M16 M20 M25 M32 M40 M50 M63 Terminal Block Population for Increased Safety Heat Dissipation Requirements Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 1.5 110 53 18 7 2.5 4 35 20 9 138 40 22 6 Maximum Terminal Block Wire Size (mm2) 6 10 16 25 35 50 70 95 120 150 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 43 17 2 42 14 4 Additional Testing Required, Consult Factory Notes: 1. See end of this section for applications using Multiple Terminal Block Types. 2. For other manufacturers of EE x 'e' type terminal blocks, consult factory. 3. For conduit/cable entry spacings and minimum wire bending space requirements, refer to the end of this section. 35 16 6 58 18 7 65 17 7 17 6 15 5 2 13 7 4 41 16 9 2 20 5 The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 61 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 62 TN4 Series - Single Door Clamped 25''x 18''x 7'' SS316L Enclosures with Terminals CATALOG NUMBER TN4X6-251807 TN4X6-251807-A TN4X6-251807-B TN4X6-251807-C TN4X6-251807-D TN4X6-251807-AB TN4X6-251807-CD TN4X6-251807-ABCD GLAND PLATES NONE SIDE A SIDE B SIDE C SIDE D SIDE A & B SIDE C & D SIDE A, B, C, & D 1. For Stainless Steel 304 assemblies substitute TN4X6 prefix with TN4X. 2. For Steel Powder Coated assemblies substitute TN4X6 prefix with TN4. 3. For empty Enclosure add U immediately following enclosure size (i.e. TN4X6-251807U). 3B–8 Gland Plate Entries Size NPT 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 Metric M16 M20 M25 M32 M40 M50 M63 Maximum Number of Entries* Sides A & B Sides C & D 24 12 20 10 16 8 6 3 5 3 4 2 4 2 *Note: There are (2) Gland Plates on Sides C&D. Quantity shown is for (1) Plate Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 1.5 127 61 21 8 2.5 4 41 24 11 159 46 26 7 6 Maximum Terminal Block Wire Size (mm2) 10 16 25 35 50 70 95 120 150 185 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 50 19 2 49 16 5 Additional Testing Required, Consult Factory Notes: 1. See end of this section for applications using Multiple Terminal Block Types. 2. For other manufacturers of EE x 'e' type terminal blocks, consult factory. 3. For conduit/cable entry spacings and minimum wire bending space requirements, refer to the end of this section. 40 18 7 67 21 9 75 19 8 20 6 17 6 2 15 8 4 47 18 11 2 23 6 14 3 The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 62 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 63 TN4 Series - Single Door Clamped 30''x 22''x 7'' SS316L Enclosures with Terminals CATALOG NUMBER TN4X6-302207 TN4X6-302207-A TN4X6-302207-B TN4X6-302207-C TN4X6-302207-D TN4X6-302207-AB TN4X6-302207-CD TN4X6-302207-ABCD GLAND PLATES NONE SIDE A SIDE B SIDE C SIDE D SIDE A & B SIDE C & D SIDE A, B, C, & D 1. For Stainless Steel 304 assemblies substitute TN4X6 prefix with TN4X. 2. For Steel Powder Coated assemblies substitute TN4X6 prefix with TN4. 3. For empty Enclosure add U immediately following enclosure size (i.e. TN4X6-302207U). Size NPT 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3B–9 Gland Plate Entries Maximum Number of Entries* Sides A & B Sides C & D 12 18 10 14 8 12 3 4 3 4 2 3 2 3 Metric M16 M20 M25 M32 M40 M50 M63 *Note: There are (2) Gland Plates on All Sides. Quantity shown is for (1) Plate. Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 143 69 24 10 2.5 4 46 27 12 180 52 29 6 6 Maximum Terminal Block Wire Size (mm2) 10 16 25 35 50 70 95 120 150 185 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 57 22 3 55 18 6 Additional Testing Required, Consult Factory Notes: 1. See end of this section for applications using Multiple Terminal Block Types. 2. For other manufacturers of EE x 'e' type terminal blocks, consult factory. 3. For conduit/cable entry spacings and minimum wire bending space requirements, refer to the end of this section. 46 21 8 75 23 10 84 22 9 22 7 20 7 2 17 10 5 53 21 12 2 26 7 15 3 11 1 The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 63 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 64 TN4 Series - Single Door Clamped 36''x 25''x 7'' SS316L Enclosures with Terminals CATALOG NUMBER TN4X6-362507 TN4X6-362507-A TN4X6-362507-B TN4X6-362507-C TN4X6-362507-D TN4X6-362507-AB TN4X6-362507-CD TN4X6-362507-ABCD GLAND PLATES NONE SIDE A SIDE B SIDE C SIDE D SIDE A & B SIDE C & D SIDE A, B, C, & D 1. For Stainless Steel 304 assemblies substitute TN4X6 prefix with TN4X. 2. For Steel Powder Coated assemblies substitute TN4X6 prefix with TN4. 3. For empty Enclosure add U immediately following enclosure size (i.e. TN4X6-362507U). 3B–10 Gland Plate Entries Size NPT 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 Metric M16 M20 M25 M32 M40 M50 M63 Maximum Number of Entries* Sides A & B Sides C & D 14 22 12 18 10 14 4 6 3 5 3 4 2 3 *Note: There are (2) Gland Plates on All Sides. Quantity shown is for (1) Plate. Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 158 77 26 11 2.5 4 51 30 14 198 57 32 9 6 Maximum Terminal Block Wire Size (mm2) 10 16 25 35 50 70 95 120 150 185 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 62 24 3 61 20 6 Additional Testing Required, Consult Factory Notes: 1. See end of this section for applications using Multiple Terminal Block Types. 2. For other manufacturers of EE x 'e' type terminal blocks, consult factory. 3. For conduit/cable entry spacings and minimum wire bending space requirements, refer to the end of this section. 50 23 9 83 26 11 1 93 24 10 25 8 22 7 3 19 11 5 58 23 14 3 29 8 17 3 12 1 The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 64 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 65 TN4 Series - Single Door Clamped 39''x 29''x 7'' SS316L Enclosures with Terminals CATALOG NUMBER TN4X6-392907 TN4X6-392907-A TN4X6-392907-B TN4X6-392907-C TN4X6-392907-D TN4X6-392907-AB TN4X6-392907-CD TN4X6-392907-ABCD GLAND PLATES NONE SIDE A SIDE B SIDE C SIDE D SIDE A & B SIDE C & D SIDE A, B, C, & D 1. For Stainless Steel 304 assemblies substitute TN4X6 prefix with TN4X. 2. For Steel Powder Coated assemblies substitute TN4X6 prefix TN4. 3B–11 3. For empty Enclosure add U immediately following enclosure size (i.e. TN4X6-392907U). Gland Plate Entries Size NPT 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 Maximum Number of Entries* Sides A & B Sides C & D 18 24 14 20 12 16 4 6 4 5 3 4 3 4 Metric M16 M20 M25 M32 M40 M50 M63 *Note: There are (2) Gland Plates on All Sides. Quantity shown is for (1) Plate. Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 173 84 28 12 2.5 4 56 32 15 217 63 35 10 6 Maximum Terminal Block Wire Size (mm2) 10 16 25 35 50 70 95 120 150 185 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 68 27 4 66 21 7 Additional Testing Required, Consult Factory Notes: 1. See end of this section for applications using Multiple Terminal Block Types. 2. For other manufacturers of EE x 'e' type terminal blocks, consult factory. 3. For conduit/cable entry spacings and minimum wire bending space requirements, refer to the end of this section. 55 25 9 91 28 12 1 102 27 10 27 9 24 8 3 20 12 6 64 25 15 3 32 9 19 4 13 1 The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 65 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 66 Qualifying Enclosures for Increased Safety Certification With Multiple Terminal Block Types Current (amps) 8 10 16 20 25 35 50 1.5 90 44 15 6 Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 29 17 8 113 33 18 5 Additional Testing Required, Consult Factory 16 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 36 14 2 35 11 29 Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below. Example: Current Number 2.5 16 7 (of 29) = 24% 4 20 16 (of 33) = 48% 10 35 9 (of 35) = 26% Total = 98% 3B–12 Conductor Size % of Maximum Terminal Population < 100% Notes: 1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor size and the continuous current for the designated enclosures. 2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and manufacturer's instructions. 3. Grounding terminals, bridges and grounding conductors are not counted. 4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges. 5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals and conductors should be considered. 6. Combinations not covered by the above tables may be permitted if they are determined acceptable by test. 66 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 67 Conduit/Cable & Wire Bending Guidelines Table A - Minimum Spacing Between Centers of Conduit or Cable Entries NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 NPT METRIC -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 1/16 ~ 3/8 -- 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 1-1/8 [29mm] 1/2 M16 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 3/4 M20 4-1/2 [115mm] 3-3/4 [96mm] 3-1/2 3-1/8 [89mm] [80mm] 2-3/4 [70mm] 2-1/2 [64mm] 2-1/8 [54mm] 2 [51mm] 1-3/4 [45mm] 1-1/2 [38mm] 1 M25 4-5/8 [118mm] 3-7/8 [99mm] 3-5/8 3-1/4 [92mm] [83mm] 2-7/8 [74mm] 2-3/4 [70mm] 2-1/4 [58mm] 2-1/8 [54mm] 1-7/8 [48mm] 1-1/4 M32 4-7/8 [124mm] 4-1/8 [105mm] 3-7/8 [99mm 3-1/2 [89mm] 3-1/8 [80mm] 2-7/8 [74mm] 2-1/2 [64mm] 2-3/8 [61mm] 1-1/2 M40 5 [127mm] 4-1/4 4 3-5/8 [108mm] [102mm] [92mm] 3-1/4 [83mm] 3 [77mm] 2-5/8 [68mm] 2 M50 5-3/8 [137mm] 4-3/4 4-1/2 4 3-5/8 [121mm] [115mm] [102mm] [92mm] 3-3/8 [86mm] 2-1/2 M63 5-1/2 [140mm] 4-7/8 4-5/8 4-1/4 3-7/8 [124mm] [118mm] [108mm] [99mm] 3 M75 5-7/8 [150mm] 5-1/4 5 4-5/8 [134mm] [127mm] [118mm] 3-1/2 -- 6-1/4 [159mm] 5-3/4 5-1/2 [147mm] [140mm] 4 -- 6-7/8 [175mm] 6 [153mm] 5 -- 7-3/8 [188mm] 3B–13 SIZE This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and condition under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 2-13/16 [72mm] 2-1/4 [58mm] 2 [51mm] 1-3/16 [31mm] 1 [26mm] 7/8 [23mm] 11/16 [18mm] 9/16 [14mm] 1/2 [13mm] 1/2 [13mm] METRIC 1-3/4 1-7/16 [45mm] [37mm] Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls AWG 16 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0 250 350 400 500 mm sq. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1-1/2 1-1/2 1-1/2 1-1/2 2 3 3-1/2 5-1/2 6 6-1/2 7 8-1/2 10 12 13 14 [38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm] Notes: 1. The distances in Table A are recommended minimum distances between centers of conduit and cable gland entries. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. entries to the edge of an opening or inside wall of box. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 3. The distances in Table C are the minimum wire bending space requirements between terminals, partitions, or inside walls. 2. The distances in Table B are recommended minimum distances between center of conduit and cable gland ADALET Enclosure Systems • Designing Our Products Around Yours SM 67 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 68 TN4 Expanded Series - Single Door Clamped Style General Information Adalet's Single Door Clamped Terminal Enclosures are available in Stainless Steel 316L & 304 and Carbon Steel. Adalet can also supply custom size enclosures, operators, and components to suit your Increased Safety Application. Silicone gaskets, removable hinge pin, box & cover ground studs including an internal/external earthing stud, along with internal standoffs for mounting pans are included as standard. Enclosure Certifications with Terminals 3B–14 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Empty Enclosure Certifications 0539 II 2GD EEx e II Ex e II Class I, Zone 1, AEx e II Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Working Voltage Terminal Blocks Various manufacturers Material TN4 Series TN4X Series TN4X6 Series TN4 Series Gland Plates TN4X Series Gland Plates TN4X6 Series Gland Plates Mounting Pan Gasket Cover Lid Fixing Hinge TN4 Series TN4X Series TN4X6 Series Door Clamps TN4 Series TN4X Series TN4X6 Series Enclosure Mounting All Types Gland Plate Hardware All Types Grounding Box & Cover All Types Earthing Stud All Types Impact Resistant All Types Ambient Temperature Range All Types ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 D ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 1100 Volts Maximum EEx e type with wire sizes 1.5mm up to 240mm #14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray #14ga Stainless Steel 304, Brushed Finish #14ga Stainless Steel 316, Brushed Finish #10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray #10ga Stainless Steel 304, Brushed Finish #10ga Stainless Steel 316, Brushed Finish #14ga Cold Rolled Steel, Polyster Powder Coated White Silicone Sponge Continuous piano type - Steel with removable SS304 pin Continuous piano type - SS304 with removable pin Continuous piano type - SS316 with removable pin Plated Steel Clear Stainless Steel 304 Stainless Steel 316 Four (4) external lugs with .44" clearance holes/slots 300 Series stainless steel 1/4-20 Stud with 300 series stainless steel hardware 1/4-20 Stud - All components brass 7 Nm to EN50014/EN50019 -40°C to +70°C to EN50014 D 68 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 69 TN4 Expanded Series - Quick Selector 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. Enclosure Selection 1. Using the table below, select the terminal block size for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. TN4 Series 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. Maximum Physical Terminal Block Content Heat Enclosure Dissipation Table 1.5mm 2.5mm 4mm 6mm 10mm 16mm 35mm 50mm 70mm 95mm 120mm 150mm 185mm 240mm -1224XX 1224 204 168 156 147 102 56 20 16 7 3 5 0 0 0 -1612XX 1612 162 132 123 99 54 22 0 0 0 0 0 0 0 0 -1616XX 1616 216 176 164 132 81 44 17 13 12 0 0 0 0 0 -1620XX 1620 270 220 205 198 135 66 17 13 12 5 0 0 0 0 -2012XX 2012 222 183 168 138 74 31 0 0 0 0 0 0 0 0 -2016XX 2016 296 244 224 184 111 62 23 18 16 0 0 0 0 0 -2020XX 2020 370 305 280 276 185 93 23 18 16 7 0 0 0 0 -2024XX 2024 444 366 336 322 222 124 46 36 16 7 11 0 0 0 -2412XX 1224 285 234 216 174 94 39 0 0 0 0 0 0 0 0 -2416XX 2416 380 312 288 232 141 78 29 23 21 0 0 0 0 0 -2420XX 2024 475 390 360 348 235 117 29 23 21 9 0 0 0 0 -2424XX 2424 570 468 432 406 282 156 58 46 21 9 14 0 0 0 -2430XX 3024 760 624 576 522 329 195 87 46 42 18 14 9 0 0 -3016XX 3016 500 412 380 308 186 104 39 31 28 0 0 0 0 0 -3020XX 3020 625 515 475 462 310 156 39 31 28 13 0 0 0 0 -3024XX 3024 750 618 570 539 372 208 78 62 28 13 19 0 0 0 -3030XX 3030 1000 824 760 693 434 260 117 62 56 26 19 13 0 0 -3036XX 3036 1250 1030 950 847 558 312 117 93 84 26 38 13 11 11 -3624XX 3624 936 768 708 672 468 260 96 78 35 16 24 0 0 0 -3630XX 3036 1248 1024 944 864 546 325 144 78 70 32 24 16 0 0 -3636XX 3636 1560 1280 1180 1056 702 390 144 117 105 32 48 16 14 13 -4224XX 4224 1116 918 846 798 558 312 116 92 42 19 29 0 0 0 -4230XX 4230 1488 1224 1128 1026 651 390 174 92 84 38 29 19 0 0 -4824XX 4824 1302 1068 984 931 648 364 134 108 49 22 33 0 0 0 -4830XX 4830 1736 1424 1312 1197 756 455 201 108 98 44 33 22 0 0 -4836XX 4836 2170 1780 1640 1463 972 546 201 162 147 44 66 22 19 19 -6036XX 6036 2780 2280 2100 1881 1251 696 258 207 186 58 86 29 24 24 3B–15 Sizes Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 2. Quantities shown above are for Adalet supplied standard terminal blocks. 69 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 70 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. Heat Dissipation Table MA2,5/5… MA2,5/5.1… M4/6… M6/8… M10/10… M16/12… M35/16… M70/22… M4/6.H… M1,5/6.HH MTC6 MA2,5/5.SNB M4/6.SN… M4/6.SNB M6/8.SNB M4/8.SN DR4/6… 3B–16 TN Series Manufacturer - Entrelec -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 198 159 212 265 219 292 365 438 279 372 465 558 744 492 615 738 984 1230 918 1224 1530 1098 1464 1278 1704 2130 2730 198 159 212 265 219 292 365 438 279 372 465 558 744 492 615 738 984 1230 918 1224 1530 1098 1464 1278 1704 2130 2730 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 126 99 132 165 138 184 230 276 177 236 295 354 472 312 390 468 624 780 582 776 970 696 928 810 1080 1350 1730 80 54 81 108 74 111 148 185 94 141 188 235 329 186 248 310 434 558 385 539 693 465 651 540 756 972 1242 56 22 44 66 31 62 93 124 39 78 117 156 195 104 156 208 260 312 256 320 384 308 385 360 450 540 690 20 0 16 16 0 23 23 46 0 29 29 58 87 39 39 78 117 156 96 144 192 116 174 134 201 268 344 7 0 0 12 0 0 16 16 0 0 21 21 42 0 28 28 56 84 35 70 105 42 84 49 98 147 186 168 88 176 220 122 244 305 366 156 312 390 468 546 412 515 618 721 927 768 896 1152 924 1078 1074 1253 1611 2061 140 88 132 176 122 183 244 305 156 234 312 390 546 309 412 515 721 927 640 896 1152 770 1078 895 1253 1611 2061 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 198 159 212 265 219 292 365 438 279 372 465 558 744 492 615 738 984 1230 918 1224 1530 1098 1464 1278 1704 2130 2730 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 126 99 132 165 138 184 230 276 177 236 295 354 472 312 390 468 624 780 582 776 970 696 928 810 1080 1350 1730 126 66 99 132 92 138 184 276 118 177 236 354 413 234 312 468 546 702 582 679 873 696 812 810 945 1215 1557 232 180 225 315 248 310 434 496 316 395 553 632 790 520 728 832 1040 1352 1032 1290 1677 1240 1550 1440 1800 2340 2990 Notes: 1. See next page for more Entrelec terminal blocks. 2. All quantities shown are for terminal blocks installed in vertical rows. 70 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 71 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. Heat Dissipation Table M35/26.FF M70/31.FF M120/35.FF M300/42.FF M35/26.AF M70.31.AF M120/35.AF M300/42.AF M120/35 M300/42 M400/52.AE D4/6…ADO D4/6.ADO.T… D4/6.ADO… D6/8…ADO D6/8.ADO… -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 18 10 10 20 14 14 28 42 18 18 36 54 72 24 48 72 96 120 90 120 150 108 144 123 164 205 265 5 0 8 8 0 12 12 12 0 15 15 15 30 20 20 20 40 60 25 50 75 30 60 35 70 105 132 4 0 0 7 0 0 10 10 0 0 13 13 26 0 17 17 34 34 22 44 44 26 52 31 62 62 78 4 0 0 6 0 0 8 8 0 0 11 11 11 0 15 15 15 30 18 18 36 22 22 25 25 50 66 18 10 10 20 14 14 28 42 18 18 36 54 72 24 48 72 96 120 90 120 150 108 144 123 164 205 265 5 0 8 8 0 12 12 12 0 15 15 15 30 20 20 20 40 60 25 50 75 30 60 35 70 105 132 4 0 0 7 0 0 10 10 0 0 13 13 26 0 17 17 34 34 22 44 44 26 52 31 62 62 78 0 0 0 0 0 0 0 0 0 0 0 0 11 0 0 0 15 15 0 18 18 0 22 0 25 25 33 4 0 0 7 0 0 10 10 0 0 13 13 26 0 17 17 34 34 22 44 44 26 52 31 62 62 78 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 15 0 0 18 0 0 0 0 25 33 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 0 0 15 0 0 0 0 20 26 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 924 1232 1074 1432 1790 2290 126 99 132 165 138 184 230 276 177 236 295 354 472 312 390 468 624 780 582 776 970 696 928 810 1080 1350 1730 126 99 132 165 138 184 230 276 177 236 295 354 472 312 390 468 624 780 582 776 970 696 928 810 1080 1350 1730 3B–17 TN Series Manufacturer - Entrelec Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 71 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 72 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. WDU10 WDU16 WDU35 WDU70 WDU120 WWF35 WFF70 WFF120 WFF185 WFF300 ZDU2.5 170 108 162 216 148 222 296 370 190 285 380 475 665 375 500 625 875 1000 780 1092 1248 930 1302 1085 1519 1736 2224 105 68 102 136 94 141 188 235 120 180 240 300 420 237 316 395 553 632 495 693 792 590 826 685 959 1096 1408 85 54 81 108 74 111 148 185 96 144 192 240 288 189 252 315 378 441 390 468 546 470 564 545 654 763 980 42 22 44 66 31 62 93 93 39 78 117 117 195 104 156 156 260 312 195 325 390 234 390 273 455 546 696 20 0 17 17 0 23 23 46 0 29 29 58 87 39 39 78 117 117 96 144 144 116 174 134 201 201 258 6 0 0 10 0 0 13 13 0 0 17 17 34 0 23 23 46 46 29 58 58 34 68 40 80 80 102 5 0 0 0 0 0 0 11 0 0 0 14 14 0 0 19 19 38 24 24 48 29 29 33 33 66 86 6 0 10 10 0 13 13 13 0 17 17 17 34 22 22 22 44 66 27 54 81 32 64 38 76 114 144 5 0 0 8 0 0 11 11 0 0 14 14 28 0 19 19 38 38 23 46 46 27 54 32 64 64 82 4 0 0 0 0 0 0 8 0 0 0 11 11 0 0 14 14 28 18 18 36 21 21 25 25 50 64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 0 0 14 0 0 0 0 19 24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 0 0 14 0 0 0 0 19 24 165 106 159 212 146 219 292 365 186 279 372 465 651 369 492 615 861 984 765 1071 1224 915 1281 1065 1491 1704 2184 140 105 297 88 66 216 132 99 270 176 132 378 122 92 296 183 138 370 244 184 518 305 230 666 156 116 376 234 174 470 312 232 658 390 290 846 546 406 1034 309 231 625 412 308 875 515 385 1125 721 539 1375 824 616 1625 640 480 1395 896 672 1705 1024 768 2015 765 570 1674 1071 798 2046 890 665 1944 1246 931 2376 1424 1064 2808 1824 1368 3601 AKE2.5 WDU6 170 108 162 216 148 222 296 370 190 285 380 475 665 375 500 625 875 1000 780 1092 1248 930 1302 1085 1519 1736 2224 AKZ4 WDU4 204 162 216 270 222 296 370 444 285 380 475 570 760 500 625 750 1000 1250 936 1248 1560 1116 1488 1302 1736 2170 2780 AKZ2.5 WDU2.5 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 ZDU6 WDU2.5N -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX ZDU4 Heat Dissipation Table 3B–18 TN Series Manufacturer - Weidmuller 243 176 220 308 244 305 427 549 308 385 539 693 847 510 714 918 1122 1326 1143 1397 1651 1368 1672 1593 1947 2301 2951 264 216 270 378 296 370 518 592 376 470 658 752 940 625 875 1000 1250 1625 1240 1550 2015 1488 1860 1728 2160 2808 3601 Notes: 1. See next page for more Weidmuller terminal blocks. 2. All quantities shown are for terminal blocks installed in vertical rows. 3. Weidmuller WFF Series are installed on a mounting pan. 72 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 73 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. SAKG 28 II SAKG 28 III SAKG 32 I SAKG 32 II SAKG 32 III SAKG 40 I SAKG 40 II SAKG 40 III SAKG 46 II SAKG 54 II 147 102 99 54 132 81 198 135 138 74 184 111 276 185 322 222 174 94 232 141 348 235 406 282 522 329 308 186 462 310 539 372 693 434 847 558 672 468 864 546 1056 702 798 558 1026 651 931 648 1197 756 1463 972 1881 1251 56 22 44 66 31 62 93 124 39 78 117 156 195 104 156 208 260 312 260 325 390 312 390 364 455 546 696 20 0 17 17 0 23 23 46 0 29 29 58 87 39 39 78 117 117 96 144 144 116 174 134 201 201 258 7 0 12 12 0 16 16 16 0 21 21 21 42 28 28 28 56 84 35 70 105 42 84 49 98 147 186 10 0 9 9 0 12 12 24 0 15 15 30 30 20 20 40 40 60 50 50 75 60 60 70 70 105 138 10 0 9 9 0 12 12 24 0 15 15 30 30 20 20 40 40 60 50 50 75 60 60 70 70 105 138 10 0 9 9 0 12 12 24 0 15 15 30 30 20 20 40 40 60 50 50 75 60 60 70 70 105 138 5 0 0 8 0 0 11 11 0 0 14 14 28 0 18 18 36 36 23 46 46 27 54 31 62 62 80 5 0 0 8 0 0 11 11 0 0 14 14 28 0 18 18 36 54 23 46 69 27 54 31 62 93 120 5 0 0 8 0 0 11 11 0 0 14 14 28 0 18 18 36 36 23 46 46 27 54 31 62 62 80 3 0 0 5 0 0 7 7 0 0 9 9 18 0 13 13 26 26 16 32 32 19 38 22 44 44 58 3 0 0 5 0 0 7 7 0 0 9 9 18 0 13 13 26 26 16 32 32 19 38 22 44 44 58 3 0 0 5 0 0 7 7 0 0 9 9 18 0 13 13 26 26 16 32 32 19 38 22 44 44 58 0 0 0 0 0 0 0 0 0 0 0 0 9 0 0 0 13 13 0 16 16 0 19 0 22 22 29 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 0 0 13 0 0 0 0 19 24 3B–19 SAKG 28 I 156 123 164 205 168 224 280 336 216 288 360 432 576 380 475 570 760 950 708 944 1180 846 1128 984 1312 1640 2100 SAK70 SAK4 168 132 176 220 183 244 305 366 234 312 390 468 624 412 515 618 824 1030 768 1024 1280 918 1224 1068 1424 1780 2280 SAK35N SAK2.5 200 117 195 234 162 270 324 432 207 345 414 552 690 455 546 728 910 1092 904 1130 1356 1088 1360 1264 1580 1896 2424 SAK16 AKE4 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 SAK10 Heat Dissipation Table -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX SAK6N TN Series Manufacturer - Weidmuller Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 73 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 74 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. Heat Dissipation Table 30128 gr 3424 gr 3425 gr 3426 gr 3427 gr 3428 gr 3429 gr 30841 gr Ex 30842 gr Ex 30843 gr Ex 30844 gr Ex 3468 gr Ex 3469 gr Ex 30111 gr 3301 gr 3B–20 TN Series Manufacturer - Wortez -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 168 135 180 225 186 248 310 372 237 316 395 474 632 420 525 630 840 1050 780 1040 1300 936 1248 1086 1448 1810 2320 168 135 180 225 186 248 310 372 237 316 395 474 632 420 525 630 840 1050 780 1040 1300 936 1248 1086 1448 1810 2320 126 102 136 170 141 188 235 282 177 236 295 354 472 312 390 468 624 780 582 776 970 696 928 810 1080 1350 1740 95 60 90 120 82 123 164 205 106 159 212 265 318 210 280 350 420 560 435 522 696 520 624 600 720 960 1232 60 25 50 75 34 68 102 136 43 86 129 172 215 114 171 228 285 342 284 355 426 340 425 392 490 588 756 24 0 19 19 0 26 26 52 0 34 34 68 102 45 45 90 135 135 110 165 165 132 198 154 231 231 297 7 0 11 11 0 16 16 16 0 20 20 20 40 27 27 27 54 81 34 68 102 40 80 47 94 141 180 84 66 88 110 90 120 150 180 114 152 190 228 304 200 250 300 400 500 372 496 620 450 600 522 696 870 1110 60 38 57 76 52 78 104 130 66 99 132 165 231 129 172 215 301 344 270 378 432 320 448 375 525 600 768 40 16 32 48 22 44 66 88 29 58 87 116 145 76 114 152 190 228 188 235 282 224 280 264 330 396 504 16 0 13 13 0 18 18 36 0 22 22 44 66 30 30 60 90 90 74 111 111 88 132 102 153 153 198 6 0 9 9 0 13 13 13 0 17 17 17 34 22 22 22 44 66 28 56 84 33 66 38 76 114 147 5 0 0 8 0 0 11 11 0 0 14 14 14 0 18 18 18 36 23 23 46 27 27 32 32 64 82 168 135 180 225 186 248 310 372 237 316 395 474 632 420 525 630 840 1050 780 1040 1300 936 1248 1086 1448 1810 2320 168 135 180 225 186 248 310 372 237 316 395 474 632 420 525 630 840 1050 780 1040 1300 936 1248 1086 1448 1810 2320 Notes: 1. See next page for more Wortez terminal blocks. 2. All quantities shown are for terminal blocks installed in vertical rows. 74 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 75 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. Heat Dissipation Table 3302 gr 3303 gr 3304 gr 3305 gr 3306 gr 3712 gr Ex 3713 gr Ex 3713/16 gr Ex 3714 gr Ex 3715 gr Ex 3716 gr Ex 30831 gr Ex 30832 gr Ex 30833 gr Ex 30834 gr Ex -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 126 102 136 170 141 188 235 282 177 236 295 354 472 312 390 468 624 780 582 776 970 696 928 810 1080 1350 1740 95 60 90 120 82 123 164 205 106 159 212 265 318 210 280 350 420 560 435 522 696 520 624 600 720 960 1232 60 25 50 75 34 68 102 136 43 86 129 172 215 114 171 228 285 342 284 355 426 340 425 392 490 588 756 24 0 19 19 0 26 26 52 0 34 34 68 102 45 45 90 135 135 110 165 165 132 198 154 231 231 297 7 0 11 11 0 16 16 16 0 20 20 20 40 27 27 27 54 81 33 66 99 40 80 47 94 141 180 84 57 76 95 81 108 135 189 102 136 170 238 306 180 225 315 405 450 392 504 560 462 594 539 693 770 990 60 34 51 68 46 69 92 138 60 90 120 180 210 117 156 234 273 351 294 343 441 348 406 408 476 612 783 36 14 28 42 19 38 57 76 25 50 75 100 125 66 99 132 165 198 164 205 246 196 245 228 285 342 438 14 0 12 12 0 17 17 34 0 21 21 42 63 28 28 56 84 112 70 105 140 84 126 98 147 196 252 6 0 9 9 0 13 13 13 0 17 17 17 34 22 22 22 44 66 28 56 84 33 66 38 76 114 147 5 0 0 8 0 0 11 11 0 0 14 14 14 0 18 18 18 36 23 23 46 27 27 32 32 64 82 98 66 88 110 90 120 150 210 114 152 190 266 342 200 250 350 450 500 434 558 620 525 675 609 783 870 1110 72 38 57 76 52 78 104 156 66 99 132 198 231 129 172 258 301 387 324 378 486 384 448 450 525 675 864 40 16 32 48 22 44 66 88 29 58 87 116 145 76 114 152 190 228 188 235 282 224 280 264 330 396 504 16 0 13 13 0 18 18 36 0 22 22 44 66 30 30 60 90 90 74 111 111 88 132 102 153 153 198 3B–21 TN Series Manufacturer - Wortez Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 75 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 76 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. MZDB 1,5 MZDB 1,5-NS 35 ZFK 1,5 ZKF 2,5 ZFK 4 ZFK 6 22 0 18 18 0 24 24 48 0 31 31 62 93 41 41 82 123 164 102 153 204 122 183 142 213 284 364 MZB 1,5-NS 35 56 22 44 66 30 60 90 120 39 78 117 156 195 102 153 204 255 357 256 320 448 304 380 356 445 623 798 MZB 1,5 UK 35 80 52 78 104 72 108 144 180 92 138 184 230 322 183 244 305 427 549 380 532 684 455 637 530 742 954 1224 UK 3-RETURN UK 16 N 140 99 132 165 135 180 225 315 174 232 290 406 464 304 380 532 608 760 665 760 950 791 904 924 1056 1320 1690 MBK 6/E UK 10 N 189 132 176 220 180 240 300 420 228 304 380 532 608 404 505 707 808 1010 882 1008 1260 1050 1200 1225 1400 1750 2240 MBK 2,5/E-EX UK 6 N 231 156 208 260 216 288 360 504 273 364 455 637 728 480 600 840 960 1200 1050 1200 1500 1253 1432 1456 1664 2080 2670 UKH 240 UK 5 N 231 156 208 260 216 288 360 504 273 364 455 637 728 480 600 840 960 1200 1050 1200 1500 1253 1432 1456 1664 2080 2670 UKH 150 UK 3 N 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 UKH 95 UK 2,5 N -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX 16 6 0 0 13 0 13 10 0 0 18 0 18 15 36 15 0 0 23 0 23 19 46 19 46 38 31 0 31 25 62 25 62 50 93 50 78 31 78 62 117 62 92 37 92 74 108 43 108 86 162 86 207 110 0 0 0 0 0 0 0 0 0 0 0 0 15 0 0 0 20 20 0 25 25 0 30 0 35 35 44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 17 0 0 21 0 0 0 0 30 38 243 176 220 308 240 300 420 540 304 380 532 684 836 505 707 909 1111 1313 1134 1386 1638 1350 1650 1575 1925 2275 2912 140 99 165 198 135 225 270 315 174 290 348 406 522 380 456 532 684 836 665 855 1045 791 1017 924 1188 1452 1859 198 156 208 260 216 288 360 432 273 364 455 546 728 480 600 720 960 1200 900 1200 1500 1074 1432 1248 1664 2080 2670 264 156 260 312 216 360 432 576 273 455 546 728 910 600 720 960 1200 1440 1200 1500 1800 1432 1790 1664 2080 2496 3204 231 156 208 260 216 288 360 504 273 364 455 637 728 480 600 840 960 1200 1050 1200 1500 1253 1432 1456 1664 2080 2670 128 78 130 156 108 180 216 288 138 230 276 368 460 305 366 488 610 732 600 750 900 720 900 840 1050 1260 1608 112 78 104 130 108 144 180 252 138 184 230 322 368 244 305 427 488 610 525 600 750 630 720 735 840 1050 1340 246 130 195 325 178 267 445 534 226 339 565 678 791 450 750 900 1050 1350 1116 1302 1674 1332 1554 1554 1813 2331 2979 198 104 156 260 144 216 360 432 182 273 455 546 637 360 600 720 840 1080 900 1050 1350 1074 1253 1248 1456 1872 2403 135 88 132 176 120 180 240 300 152 228 304 380 532 303 404 505 707 909 630 882 1134 750 1050 875 1225 1575 2016 100 66 99 132 90 135 180 225 116 174 232 290 348 228 304 380 456 608 475 570 760 565 678 660 792 1056 1352 UKH 50 Heat Dissipation Table 3B–22 TN Series Manufacturer - Phoenix Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 76 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 77 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete Enclosure Size, Refer to Catalog Page 3B–24 for Enclosure Prefix and Depth. 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 1. Using the table below, find the Heat Dissipation Table Number for the enclosure size you selected. 2. Refer to catalog page 3B–26 for Heat Dissipation Tables. WKN 35/U WKN 70/U WKN 150/U 32 0 27 27 0 37 37 74 0 47 47 94 141 62 62 124 186 186 154 231 231 186 279 216 324 324 414 80 54 81 108 74 111 148 185 94 141 188 235 282 186 248 310 372 496 385 462 616 465 558 540 648 864 1104 42 22 44 66 31 62 93 93 39 78 117 117 195 104 156 156 260 312 192 320 384 231 385 270 450 540 690 20 0 17 17 0 23 23 46 0 29 29 58 58 39 39 78 78 117 96 96 144 116 116 134 134 201 258 7 0 0 11 0 0 15 15 0 0 19 19 38 0 26 26 52 78 32 64 96 38 76 45 90 135 171 6 0 0 0 0 0 0 13 0 0 0 16 16 0 0 22 22 22 27 27 27 33 33 38 38 38 49 3B–23 WKN 16/U 168 126 135 99 180 132 225 165 186 138 248 184 310 230 372 276 237 177 316 236 395 295 474 354 632 472 416 312 520 390 624 468 832 624 1040 780 774 582 1032 776 1290 970 930 696 1240 928 1080 810 1440 1080 1800 1350 2310 1730 WKN 10/U 198 162 216 270 222 296 370 444 282 376 470 564 752 500 625 750 1000 1250 930 1240 1550 1116 1488 1296 1728 2160 2770 WKI 35/U 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 WK 6/U WK 2.5/U -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX WK 4/U Heat Dissipation Table 264-225 264-125 232 160 203 119 138 96 138 81 230 160 184 108 276 192 276 162 189 135 189 111 315 225 252 148 378 270 378 222 504 360 441 259 237 171 237 141 395 285 316 188 474 342 474 282 632 456 553 329 790 570 711 423 525 375 420 252 630 450 630 378 840 600 735 441 1050 750 945 567 1260 900 1155 693 1040 744 910 546 1300 930 1170 702 1560 1116 1430 858 1248 888 1092 651 1560 1110 1404 837 1448 1032 1267 756 1810 1290 1629 972 2172 1548 1991 1188 2784 1992 2552 1529 TN Series 198 140 156 88 208 132 260 176 213 122 284 183 355 244 426 305 270 154 360 231 450 308 540 385 720 539 476 306 595 408 714 510 952 714 1071 816 882 630 1176 882 1323 1008 1056 755 1408 1057 1230 875 1640 1225 1845 1400 2358 1800 264-220 20 15 15 30 21 21 42 42 27 27 54 54 81 36 72 72 108 144 90 135 180 108 162 124 186 248 320 264-120 56 23 46 69 31 62 93 124 39 78 117 156 195 104 156 208 260 312 260 325 390 312 390 360 450 540 696 281-693 285-691 168 140 105 85 88 88 68 54 176 132 102 81 220 176 136 108 122 122 94 74 244 183 141 111 305 244 188 148 366 305 235 185 154 154 118 94 308 231 177 141 385 308 236 188 462 385 295 235 539 539 413 282 408 306 234 189 510 408 312 252 612 510 390 315 714 714 546 378 918 918 624 504 756 630 490 390 882 882 686 468 1134 1134 784 624 906 755 585 465 1057 1057 819 558 1050 875 680 540 1225 1225 952 648 1575 1575 1088 864 2025 2025 1392 1112 280-698 283-691 Manufacturer - Wieland 284-691 198 104 208 260 142 284 355 426 180 360 450 540 630 476 595 714 833 1071 882 1029 1323 1056 1232 1230 1435 1845 2358 282-691 280-991 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3024 3016 3020 3024 3030 3036 3624 3036 3636 4224 4230 4824 4830 4836 6036 281-991 Heat Dissipation Table -1224XX -1612XX -1616XX -1620XX -2012XX -2016XX -2020XX -2024XX -2412XX -2416XX -2420XX -2424XX -2430XX -3016XX -3020XX -3024XX -3030XX -3036XX -3624XX -3630XX -3636XX -4224XX -4230XX -4824XX -4830XX -4836XX -6036XX 281-691 TN Series Manufacturer - Wago Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 77 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 78 TN4 Expanded Series - Enclosure Outline 3B–24 ENCLOSURE SIZE -1224xx -1612xx -1616xx -1620xx -2012xx -2016xx -2020xx -2024xx -2412xx -2416xx -2420xx -2424xx -301606 -3020xx -3024xx -3624xx -3630xx -2430xx -3030xx -303608 -3636xx -422408 -4230xx -4236xx -482408 -4830xx -4836xx -6036xx H 305 406 406 406 508 508 508 508 610 610 610 610 762 762 762 914 914 610 762 762 914 1067 1067 1067 1219 1219 1219 1524 W 610 305 406 508 305 406 508 610 305 406 508 610 406 508 610 610 762 762 762 914 914 610 762 914 610 762 914 914 06 152 152 152 152 152 152 152 152 152 152 152 152 152 152 152 152 152 ------------ 08 203 203 203 203 203 203 203 203 203 203 203 203 -203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 10 -254 ---254 254 -254 -254 254 -254 254 254 254 -----254 254 -254 254 254 D 12 -----305 ----305 305 --305 305 305 -305 -305 -305 305 --305 305 16 ----------406 406 --406 -406 ------406 --406 406 20 --------------508 -508 ---------508 508 24 --------------588 ------------588 M N S T 359 460 460 460 562 562 562 562 664 664 664 664 816 816 816 968 968 664 816 816 968 1121 1121 1121 1273 1273 1273 1578 458 241 254 356 241 254 356 458 241 254 356 458 254 356 458 458 610 610 610 762 762 458 610 762 458 610 762 762 229 330 330 330 432 432 432 432 534 534 534 534 686 686 686 838 838 534 686 686 838 991 991 991 1143 1143 1143 1448 534 229 330 432 229 330 432 534 229 330 432 534 330 432 534 534 686 686 686 838 838 534 686 838 534 686 838 838 # OF CLAMPS 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 7 7 7 7 7 6 8 8 6 8 8 9 STIFFENER BOX COVER ----------------------------------------------------------------REQ'D REQ'D ----REQ'D REQ'D REQ'D REQ'D REQ'D REQ'D --REQ'D REQ'D REQ'D REQ'D REQ'D --REQ'D REQ'D REQ'D REQ'D REQ'D REQ'D REQ'D NOTES: 1. Dimensions in table are Metric. 2. xx in Enclosure Size indicates multiple depths. Complete Enclosure Size with depths indicated in Column D (i.e. 122408). 78 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 79 TN4 Expanded Series - Catalog Numbers TN4X6-122408 TN4X6-161208 TN4X6-161608 TN4X6-162008 TN4X6-201208 TN4X6-201608 TN4X6-202008 TN4X6-202408 TN4X6-241208 TN4X6-241608 TN4X6-242008 TN4X6-242408 TN4X6-302008 TN4X6-302408 TN4X6-362408 TN4X6-363008 TN4X6-243008 TN4X6-303008 TN4X6-303608 TN4X6-363608 TN4X6-422408 TN4X6-423008 TN4X6-423608 TN4X6-482408 TN4X6-483008 TN4X6-483608 TN4X6-603608 1224 1612 1616 1620 2012 2016 2020 2024 1224 2416 2024 2424 3020 3024 3624 3036 3024 3030 3036 3636 4224 4230 4236 4824 4830 4836 6036 SS316L Enclosures with Terminals Catalog Numbers Heat Dissipation Table TN4X6-161210 1612 TN4X6-201610 2016 TN4X6-202010 2020 TN4X6-241210 2412 TN4X6-242010 2024 TN4X6-242410 2424 TN4X6-302010 3020 TN4X6-302410 3024 TN4X6-362410 3624 TN4X6-363010 3036 TN4X6-483010 4830 TN4X6-483610 4836 TN4X6-603610 6036 TN4X6-201612 TN4X6-242012 TN4X6-242412 TN4X6-302412 TN4X6-362412 TN4X6-363012 TN4X6-303012 TN4X6-363612 TN4X6-423012 TN4X6-423612 TN4X6-483612 TN4X6-603612 2016 2024 2424 3024 3624 3036 3030 3636 4230 4236 4836 6036 TN4X6-242016 TN4X6-242416 TN4X6-302416 TN4X6-363016 TN4X6-423616 TN4X6-483616 TN4X6-603616 2024 2424 3024 3036 4236 4836 6036 Mounting Pans Enclosure Size Catalog Numbers -1224xx V2412 -1612xx V1612 -1616xx V1616 -1620xx V1620 -2012xx V2012 -2016xx V2016 -2020xx V2020 -2024xx V2420 -2412xx V2412 -2416xx V2416 -2420xx V2420 -2424xx V2424 -3020xx V3020 -3024xx V3024 -3624xx V3624 -3630xx -2430xx -3030xx -3036xx -3636xx -4224xx -4230xx -4236xx -4824xx -4830xx -4836xx -6036xx V3630 V3024 V3030 V3036 V3636 V4224 V4230 V4236 V4824 V4830 V4836 V6036 3B–25 SS316L Enclosures with Terminals Catalog Numbers Heat Dissipation Table TN4X6-122406 1224 TN4X6-161206 1612 TN4X6-161606 1616 TN4X6-162006 1620 TN4X6-201206 2012 TN4X6-201606 2016 TN4X6-202006 2020 TN4X6-202406 2024 TN4X6-241206 2412 TN4X6-241606 2416 TN4X6-242006 2024 TN4X6-242406 2424 TN4X6-301606 3016 TN4X6-302006 3020 TN4X6-302406 3024 TN4X6-362406 3624 TN4X6-363006 3036 NOTES: 1. For Stainless Steel 304 assemblies substitute TN4X6 prefix with TN4X. 2. For Steel Powder Coated assemblies substitute TN4X6 prefix with TN4. 3. For Empty Enclosures add U immediately following enclosure size (i.e. TN4X6-122406U). 4. For Stainless Steel Mounting Pan add S to catalog number (i.e. V2412S). TN4X6-302420 TN4X6-363020 TN4X6-483620 TN4X6-603620 3024 3036 4836 6036 TN4X6-483624 TN4X6-603624 4836 6036 5. For Aluminum Mounting Pan add A to catalog number (i.e. V2412A). 6. For Increased Safety Applications, refer to Heat Dissipation Tables indicated next to Catalog number. 79 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 80 Heat Dissipation Tables Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 3B–26 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 1224 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 95 46 15 30 119 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 6 18 34 8 19 37 5 14 36 2 12 30 4 14 50 5 15 56 6 14 6 15 5 13 4 11 35 Additional Testing Required, Consult Factory 1 6 13 3 8 1 150 17 5 185 10 2 1612 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (Amps) 1.5 2.5 4 6 10 16 25 35 50 70 95 8 90 10 44 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 16 15 29 113 20 6 17 33 25 8 18 36 35 5 14 35 50 2 11 29 63 3 13 47 80 5 15 53 100 6 14 125 5 14 160 4 12 200 4 10 Additional Testing Required, Consult Factory 225 1 6 250 3 1616 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (Amps) 1.5 2.5 4 6 10 16 25 35 50 70 95 8 100 10 48 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 16 16 32 125 20 7 19 36 25 9 20 39 35 6 15 38 50 2 12 32 63 4 14 52 80 5 16 59 100 7 15 125 6 15 160 5 14 200 5 12 Additional Testing Required, Consult Factory 225 1 7 250 3 Notes: 1. See the end of this section for applications using multiple terminal blocks. 80 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 81 Heat Dissipation Tables 1620 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 106 51 17 34 133 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 7 20 38 9 22 24 6 16 41 2 13 34 4 15 56 6 17 62 7 16 6 16 5 14 5 12 39 Additional Testing Required, Consult Factory 2 7 15 3 9 2 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 2012 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 93 45 15 30 117 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 6 17 34 8 19 37 5 14 36 2 11 29 4 13 49 5 15 55 6 14 5 14 5 13 4 11 34 Additional Testing Required, Consult Factory 1 6 13 3 8 1 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 2016 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 106 51 17 34 133 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 7 20 38 9 22 42 6 16 41 2 13 34 4 15 56 6 17 62 7 16 6 16 5 14 5 12 39 Additional Testing Required, Consult Factory 2 7 15 3 9 2 Qualifying Enclosure for Increased Safety Certification 150 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 19 5 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 150 3B–27 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 17 5 150 Notes: 19 5 1. See the end of this section for applications using multiple terminal blocks. 81 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 82 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 3B–28 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 2020 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 115 66 19 37 144 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 8 22 42 10 23 45 7 18 44 2 14 36 4 17 60 6 19 67 8 18 7 18 6 16 5 13 42 Additional Testing Required, Consult Factory 2 8 16 4 10 2 2024 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 121 59 20 39 152 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 8 23 44 10 25 48 7 18 46 2 15 38 5 18 64 7 20 71 8 18 7 19 6 16 6 14 45 Additional Testing Required, Consult Factory 2 8 17 4 10 2 2412 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 95 46 15 30 119 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 6 18 34 8 19 5 37 14 2 36 12 4 Additional Testing Required, Consult Factory 30 14 5 50 15 6 56 14 6 15 5 13 4 1 11 6 3 35 13 8 1 Qualifying Enclosure for Increased Safety Certification 150 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 21 6 150 22 12 150 185 13 3 185 Notes: 17 5 10 2 1. See the end of this section for applications using multiple terminal blocks. 82 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 83 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 2416 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 110 53 18 35 138 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 7 20 40 9 22 43 6 17 42 2 13 35 4 16 58 6 18 64 7 17 6 17 6 15 5 13 40 Additional Testing Required, Consult Factory 2 7 16 4 9 2 2424 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 130 63 21 42 113 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 9 24 47 11 26 51 7 20 50 3 16 41 5 19 68 7 21 76 9 20 1 8 20 7 18 6 15 48 Additional Testing Required, Consult Factory 2 9 19 4 11 2 1.5 139 67 23 9 Qualifying Enclosure for Increased Safety Certification 150 174 50 28 8 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 20 5 150 24 7 2430 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 45 51 12 185 12 2 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 185 3B–29 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 14 3 185 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 55 21 3 53 17 6 Additional Testing Required, Consult Factory 44 20 8 73 23 9 1 82 21 8 22 7 19 7 2 16 9 5 51 20 12 2 25 7 Notes: 15 3 10 1 1. See the end of this section for applications using multiple terminal blocks. 83 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 84 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 3B–30 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 113 55 18 7 3016 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 36 21 10 142 41 23 6 160 46 26 45 17 2 43 14 4 36 16 6 59 18 8 66 17 7 17 6 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 15 5 2 13 7 4 42 16 10 2 20 6 50 19 2 49 16 5 40 19 7 67 21 9 75 19 8 20 7 17 6 2 15 8 4 47 18 11 2 23 6 3024 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 45 26 12 174 50 28 8 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 12 2 185 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 8 1 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 139 67 23 9 240 2. Find the Current (amperage) you intend to apply to the conductor. 3020 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 41 24 11 185 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 127 62 21 8 Qualifying Enclosure for Increased Safety Certification 14 3 185 9 1 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 55 21 3 53 17 6 Additional Testing Required, Consult Factory 44 20 8 73 23 9 82 21 8 22 7 19 7 2 16 9 5 51 20 12 2 25 7 Notes: 15 3 10 1 1. See the end of this section for applications using multiple terminal blocks. 84 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 85 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 152 74 25 10 3030 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 49 28 13 191 55 31 9 203 59 33 9 60 23 3 58 19 6 48 22 8 80 25 10 1 89 23 9 24 8 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 21 7 2 18 10 5 56 22 13 2 28 8 64 25 3 62 20 7 51 24 9 85 26 11 1 95 25 10 25 8 22 8 3 19 11 12 60 23 14 3 30 8 3624 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 46 27 13 182 52 30 8 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 16 3 185 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 11 1 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 145 70 24 10 240 2. Find the Current (amperage) you intend to apply to the conductor. 3036 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 52 30 14 185 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 162 78 27 11 Qualifying Enclosure for Increased Safety Certification 3B–31 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 18 4 185 12 1 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 57 22 3 56 18 6 Additional Testing Required, Consult Factory 46 21 8 76 24 10 85 22 9 22 7 20 7 2 17 10 5 53 21 12 2 26 7 Notes: 16 3 11 1 1. See the end of this section for applications using multiple terminal blocks. 85 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 86 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 3B–32 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 175 85 29 12 3636 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 56 33 15 219 63 36 10 187 54 30 9 69 27 4 67 22 7 56 56 10 92 28 12 1 103 27 11 27 9 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 24 8 3 21 12 6 64 25 15 3 23 9 59 23 3 57 18 6 47 22 8 78 24 10 1 87 23 9 23 8 20 7 2 18 10 5 55 22 13 2 27 8 4230 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 54 31 15 211 61 34 10 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 19 4 185 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 13 1 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 168 82 28 11 240 2. Find the Current (amperage) you intend to apply to the conductor. 4224 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 48 28 13 185 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 149 72 24 10 Qualifying Enclosure for Increased Safety Certification 16 3 185 11 1 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 67 26 3 65 21 7 Additional Testing Required, Consult Factory 54 25 9 88 27 12 1 99 26 10 26 9 23 8 3 20 11 6 62 24 15 3 31 9 Notes: 18 4 12 1 1. See the end of this section for applications using multiple terminal blocks. 86 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 87 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 184 89 30 12 4236 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 59 34 16 231 67 38 11 73 28 4 190 55 31 9 71 23 7 59 27 10 97 30 13 108 28 11 29 10 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 25 9 3 22 12 6 68 26 16 3 34 9 60 43 3 58 19 6 48 22 8 79 25 10 1 89 23 9 24 8 21 7 2 18 10 5 56 22 13 2 28 8 4830 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 56 32 15 217 63 35 10 1. Find the Wire Size (conductor) you intend to use to connect to the terminal block. 20 4 185 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. 14 2 5. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 173 84 29 12 240 2. Find the Current (amperage) you intend to apply to the conductor. 4824 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 49 28 13 185 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 151 73 25 10 Qualifying Enclosure for Increased Safety Certification 3B–33 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 16 3 185 11 1 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 69 27 4 67 22 7 Additional Testing Required, Consult Factory 55 25 10 91 28 12 1 102 27 11 27 9 24 8 3 21 12 6 64 25 15 3 32 9 Notes: 19 4 13 1 1. See the end of this section for applications using multiple terminal blocks. 87 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 88 Heat Dissipation Tables Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 3B–34 Current (Amps) 8 10 16 20 25 35 50 63 80 100 125 160 200 225 250 315 400 500 1.5 192 93 32 13 4836 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 62 36 17 240 70 39 11 76 30 4 74 24 8 61 28 11 101 31 13 113 30 12 30 10 26 9 3 23 13 7 71 28 17 3 35 10 6036 - Terminal Block Population for Increased Safety Heat Dissipation Requirements Maximum Terminal Block Wire Size (mm2) 2.5 4 6 10 16 25 35 50 70 95 120 150 65 38 18 253 73 41 12 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances Additional Testing Required, Consult Factory 1.5 202 98 33 14 185 21 4 185 14 2 240 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 80 31 4 78 25 8 64 30 11 106 33 14 1 Additional Testing Required, Consult Factory 119 32 12 32 11 28 10 3 24 14 7 75 29 18 3 37 10 22 10 15 2 Notes: 1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor size and the continuous current for the designated enclosures. 2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and manufacturer's instructions. 3. Grounding terminals, bridges and grounding conductors are not counted. 4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges. 5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals and conductors should be considered. 6. Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below. Example from Conductor Size -6036xx Table: Current Number % of Maximum Terminal Population 2.5 16 35 (of 65) = 54% 4 20 15 (of 73) = 21% 10 35 19 (of 78) = 24% Total = 99% < 100% 7. Combinations not covered by the above tables may be permitted if they are determined acceptable by test. 88 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 89 Conduit/Cable & Wire Bending Guidelines Table A - Minimum Spacing Between Centers of Conduit or Cable Entries NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 NPT METRIC -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 1/16 ~ 3/8 -- 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 1-1/8 [29mm] 1/2 M16 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 3/4 M20 4-1/2 [115mm] 3-3/4 [96mm] 3-1/2 3-1/8 [89mm] [80mm] 2-3/4 [70mm] 2-1/2 [64mm] 2-1/8 [54mm] 2 [51mm] 1-3/4 [45mm] 1-1/2 [38mm] 1 M25 4-5/8 [118mm] 3-7/8 [99mm] 3-5/8 3-1/4 [92mm] [83mm] 2-7/8 [74mm] 2-3/4 [70mm] 2-1/4 [58mm] 2-1/8 [54mm] 1-7/8 [48mm] 1-1/4 M32 4-7/8 [124mm] 4-1/8 [105mm] 3-7/8 [99mm 3-1/2 [89mm] 3-1/8 [80mm] 2-7/8 [74mm] 2-1/2 [64mm] 2-3/8 [61mm] 1-1/2 M40 5 [127mm] 4-1/4 4 3-5/8 [108mm] [102mm] [92mm] 3-1/4 [83mm] 3 [77mm] 2-5/8 [68mm] 2 M50 5-3/8 [137mm] 4-3/4 4-1/2 4 3-5/8 [121mm] [115mm] [102mm] [92mm] 3-3/8 [86mm] 2-1/2 M63 5-1/2 [140mm] 4-7/8 4-5/8 4-1/4 3-7/8 [124mm] [118mm] [108mm] [99mm] 3 M75 5-7/8 [150mm] 5-1/4 5 4-5/8 [134mm] [127mm] [118mm] 3-1/2 -- 6-1/4 [159mm] 5-3/4 5-1/2 [147mm] [140mm] 4 -- 6-7/8 [175mm] 6 [153mm] 5 -- 7-3/8 [188mm] 3B–35 SIZE This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and condition under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 2-13/16 [72mm] 2-1/4 [58mm] 2 [51mm] 1-3/16 [31mm] 1 [26mm] 7/8 [23mm] 11/16 [18mm] 9/16 [14mm] 1/2 [13mm] 1/2 [13mm] METRIC 1-3/4 1-7/16 [45mm] [37mm] Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls AWG 16 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0 250 350 400 500 mm sq. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1-1/2 1-1/2 1-1/2 1-1/2 2 3 3-1/2 5-1/2 6 6-1/2 7 8-1/2 10 12 13 14 [38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm] Notes: 1. The distances in Table A are recommended minimum distances between centers of conduit and cable gland entries. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. entries to the edge of an opening or inside wall of box. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 3. The distances in Table C are the minimum wire bending space requirements between terminals, partitions, or inside walls. 2. The distances in Table B are recommended minimum distances between center of conduit and cable gland ADALET Enclosure Systems • Designing Our Products Around Yours SM 89 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 90 TSC Series - Screw Cover Terminal Enclosure EMC Shielding For stainless steel enclosures only EMC shielding is available on the TSC4X (SS304) and TSC4X6 (SS316L) enclosures with a shielding effectiveness of >50dB through out the frequency range of 1MHz to 1000MHz. For EMC shielding add the prefix -EMC to the catalog text string, immediately following the enclosure size. (i.e. TSC4X-101006-EMC) Note: This option is not available on enclosures with gland plates installed. TSC Shielding Effectiveness 90 Attenuation in dB 80 70 60 50 40 30 20 18 Enclosure Sizes 1000 900 800 700 600 500 400 300 200 90 100 80 70 60 50 40 30 10 0 Available in 18 sizes, from 5”x5”x3” (model 050503) to 16”x16”x8” (model 161608). 20 10 Frequency (Mhz) 3B–36 Conduit/Cable Entries: Entries can be provided per a customer sketch or with detailed information on the entry locations. Please refer to Entry Spacing Tables at the end of the Increased Safety Section in the CENELEC Product Catalog. Note: This information is important and could affect the size of the enclosure you selected. Construction • Available in (3) Materials: SS304, SS316L, PowderCoated (ASA61 Grey) Steel. • Continuously Welded and Ground Smooth Seams. • Continuous One-Piece Silicone Gasket. • Welded on External Mounting Feet with 5/16” Clearance Holes. Close-up Plugs: Any unused entries must be plugged with a Certified Close-Up Plug. Adalet can provide close-up plugs in various styles and materials. Please indicate on the sketch or provide detailed information of holes to be plugged. • Captive Cover Screws. • Universal Rail Mounting System. (Mounting pan supplied standard on 050503 enclosure). Enclosure Labeling: Adalet can provide additional enclosure labeling with custom silk screening or various colors of Lamacoid™ nameplates. Please provide detailed information of the logo or text required. • Ground Studs on Box and Cover. • Internal/External Earthing Stud. Options Breather Drains: Breather Drains can be provided per customer request. They are available in Brass or Stainless Steel 316L. Please indicate on a sketch or provide detailed information for locations. Gland Plates For enclosures with depths greater than 6” These removable plates offer great flexibility for the end user to drill holes without having to remove the entire enclosure from the installation site. Grounding Busbars: Some applications might require grounding points to be terminated in the enclosure. With the use of a Ground Busbar System this can be accomplished, consult factory for options. Add the following Suffixes: -A: Gland Plate installed on top of box. -B: Gland Plate installed on bottom of box. -C: Gland Plate installed on left of box. -D: Gland Plate installed on right of box. For multiple gland plates omit dashes (i.e. TSC4X-101006-ABCD) Mounting Pans: As an alternative to the universal rail mounting system, mounting pans are available in steel/powder coated, stainless steel, and aluminum. Please indicate when requesting quote. Terminal Strip Assemblies: Various options (i.e. marking tags, protective covers, jumpers, partitions,..) are available. Please provide detailed information requesting quote. 90 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 91 TSC Series - Screw Cover Terminal Enclosure General Information Adalet's Screw Cover Terminal Enclosures are available in Stainless Steel 304 & 316 and Carbon Steel. Adalet can also supply custom size enclosures, operators, and components to suit your EEx e application. Silicone gasket, slotted captive cover bolts, box & cover ground studs including an internal/external earthing stud, and universal rail mounting system are included as standard (except 050503, mtg. pan used). 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Empty Enclosure Certifications 0539 II 2GD EEx e II Ex e II Class I, Zone 1, AEx e II Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Working Voltage Terminal Blocks Various manufacturers Material TSC4 Series TSC4X Series TSC4X6 Series TSC4 Series Gland Plates TSC4X Series Gland Plates TSC4X6 Series Gland Plates Mounting Pan Gasket Cover Gland Plates Lid Fixing All Types Enclosure Mounting All Types Gland Plate Hardware All Types Grounding Box & Cover All Types Earthing Stud All Types Impact Resistant All Types Ambient Temperature Range All Types ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 3B–37 Enclosure Certifications with Terminals D ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 1100 Volts Maximum EEx e type with wire sizes 1.5mm up to 16mm #14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray #14ga Stainless Steel 304, Brushed Finish #14ga Stainless Steel 316, Brushed Finish #10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray #10ga Stainless Steel 304, Brushed Finish #10ga Stainless Steel 316, Brushed Finish #14ga Cold Rolled Steel, Polyster Powder Coated White Silicone Sponge Silicone Sponge 1/4-20 Captive Slotted Hex Head Bolts - Stainless Steel External mounting feet with .31'' clearance holes 300 Series stainless steel 1/4-20 Stud with 300 series stainless steel hardware 1/4-20 Stud - All components brass 7 Nm to EN50014/EN50019 -40°C to +70°C to EN50014 D 91 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 92 TSC Series - Quick Selector 4. To complete Catalog Number, Refer to Catalog Page indicated next to enclosure size. Enclosure Selection 1. Using the table below, select the terminal block size for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 1. Using the table below, refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. Maximum Physical Terminal Block Content TN4 Series 3B–38 Enclosure Catalog Sizes Page -050503 3B–47 8 -060604 3B–48 13 -070704 3B–49 18 -080804 3B–50 -101006 -101008 1.5mm 2.5mm 4mm 6mm 10mm 16mm 35mm 50mm 70mm 95mm 120mm 150mm 185mm 240mm 6 6 5 0 0 0 0 0 0 0 0 0 0 11 10 8 6 0 0 0 0 0 0 0 0 0 15 14 11 9 0 0 0 0 0 0 0 0 0 46 19 17 28 11 9 0 0 0 0 0 0 0 0 3B–51 66 54 50 40 32 14 0 0 0 0 0 0 0 0 3B–52 66 54 50 40 32 14 0 0 0 0 0 0 0 0 -120604 3B–53 43 36 33 27 21 0 0 0 0 0 0 0 0 0 -120605 3B–54 43 36 33 27 21 0 0 0 0 0 0 0 0 0 -120805 3B–55 86 36 33 54 21 18 0 0 0 0 0 0 0 0 -120806 3B–56 86 36 33 54 21 18 0 0 0 0 0 0 0 0 -121206 3B–57 129 108 99 81 42 18 0 0 0 0 0 0 0 0 -121208 3B–58 129 108 99 81 42 18 0 0 0 0 0 0 0 0 -151506 3B–59 236 192 176 144 87 48 18 14 0 0 0 0 0 0 -151508 3B–60 236 192 176 144 87 48 18 14 0 0 0 0 0 0 -161206 3B–61 192 156 144 117 64 26 0 0 0 0 0 0 0 0 -161208 3B–62 192 156 144 117 64 26 0 0 0 0 0 0 0 0 -161606 3B–63 256 208 192 156 96 52 20 16 14 0 0 0 0 0 -161608 3B–64 256 208 192 156 96 52 20 16 14 0 0 0 0 0 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 2. Quantities shown above are for Adalet supplied standard terminal blocks. 92 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 93 Maximum Physical Terminal Block Content 4. To complete catalog number, refer to catalog page indicated next to the enclosure size. Enclosure Selection 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. M6/8… M10/10… M16/12… M35/16… M4/6.H… M1,5/6.HH MTC6 MA2,5/5.SN M4/6.SN… M4/6.SNB 7 12 17 44 64 64 42 42 84 84 126 126 228 228 186 186 248 248 7 12 17 44 64 64 42 42 84 84 126 126 228 228 186 186 248 248 6 10 14 38 54 54 35 35 70 70 105 105 192 192 156 156 208 208 4 8 11 28 40 40 27 27 54 54 81 81 144 144 117 117 156 156 0 6 9 11 32 32 21 21 21 21 42 42 87 87 62 62 93 93 0 0 0 9 13 13 0 0 18 18 18 18 48 48 26 26 52 52 0 0 0 0 0 0 0 0 0 0 0 0 18 18 0 0 19 19 0 10 14 19 54 54 35 35 35 35 70 70 144 144 104 104 208 208 0 10 14 19 54 54 35 35 35 35 70 70 144 144 104 104 156 156 6 10 14 38 54 54 35 35 70 70 105 105 192 192 156 156 208 208 7 12 17 44 64 64 42 42 84 84 126 126 228 228 186 186 248 248 6 10 14 38 54 54 35 35 70 70 105 105 192 192 156 156 208 208 6 10 14 38 54 54 35 35 70 70 105 105 192 192 156 156 208 208 3B–39 M4/6… 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 MA2,5/5.1… Cat. Page -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 MA2,5/5… Enclosure Size Manufacturer - Entrelec Notes: 1. See next page for more Entrelec terminal blocks. 2. All quantities shown are for terminal blocks installed in vertical rows. 93 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 94 Maximum Physical Terminal Block Content 4. To complete catalog number, refer to catalog page indicated next to the enclosure size. Enclosure Selection 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. M35/26.FF M70/31.FF M35/26.AF M70.31.AF D4/6…ADO D4/6.ADO.T… D4/6.ADO… 0 8 11 14 40 40 27 27 27 27 54 54 108 108 78 78 117 117 7 11 30 40 84 84 36 36 72 72 144 144 245 245 212 212 265 265 0 0 0 0 6 6 0 0 0 0 8 8 11 11 12 12 12 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 0 0 0 0 6 6 0 0 0 0 8 8 11 11 12 12 12 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 10 6 10 14 19 54 54 35 35 35 35 105 105 192 192 156 156 208 208 6 10 14 19 54 54 35 35 35 35 105 105 192 192 156 156 208 208 6 10 14 19 54 54 35 35 35 35 105 105 192 192 156 156 208 208 4 8 11 14 40 40 27 27 27 27 81 81 144 144 117 117 156 156 D6/8.ADO… DR4/6… 4 8 11 28 40 40 27 27 54 54 81 81 144 144 117 117 156 156 D6/8…ADO M4/8.SN 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 M6/8.SNB 3B–40 -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 Cat. Page Enclosure Size Manufacturer - Entrelec 4 8 11 14 40 40 27 27 27 27 81 81 144 144 117 117 156 156 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 94 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 95 Maximum Physical Terminal Block Content 4. To complete catalog number, refer to catalog page indicated next to the enclosure size. Enclosure Selection 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. Cat. Page WDU2.5N WDU2.5 WDU4 WDU6 WDU10 WDU16 WDU35 WWF35 ZDU2.5 ZDU4 ZDU6 AKZ2.5 AKZ4 -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 8 13 18 46 66 66 43 43 86 86 129 129 236 236 192 192 256 256 0 13 18 23 66 66 43 43 43 43 86 86 177 177 128 128 192 192 0 13 18 23 66 66 43 43 43 43 86 86 177 177 128 128 192 192 0 8 11 14 42 42 27 27 27 27 54 54 111 111 80 80 120 120 0 0 9 11 17 17 0 0 22 22 44 44 58 58 64 64 96 96 0 0 0 0 14 14 0 0 0 0 18 18 48 48 26 26 52 52 0 0 0 0 0 0 0 0 0 0 0 0 18 18 0 0 20 20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11 0 13 18 23 66 66 43 43 43 43 86 86 174 174 126 126 189 189 0 11 15 19 54 54 36 36 36 36 72 72 144 144 104 104 156 156 0 8 11 14 40 40 27 27 27 27 54 54 108 108 78 78 117 117 7 12 34 46 99 99 43 43 86 86 172 172 290 290 252 252 315 315 6 10 28 36 81 81 35 35 70 70 140 140 240 240 208 208 260 260 3B–41 Enclosure Size Manufacturer - Weidmuller Notes: 1. See next page for more Weidmuller terminal blocks. 2. All quantities shown are for terminal blocks installed in vertical rows. 95 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 96 Maximum Physical Terminal Block Content 4. To complete Catalog Number, Refer to Catalog Page indicated next to the enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. Cat. Page AKE2.5 AKE4 SAK2.5 SAK4 SAK6N SAK10 SAK16 SAK35N SAK70 SAKG 28 I SAKG 28 II SAKG 28 III 3B–42 Enclosure Size Manufacturer - Weidmuller -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 7 12 34 46 99 99 43 43 86 86 172 172 290 290 252 252 315 315 6 9 13 34 72 72 31 31 62 62 93 93 172 172 138 138 230 230 6 11 15 19 54 54 36 36 36 36 108 108 192 192 156 156 208 208 6 10 14 17 50 50 33 33 33 33 99 99 176 176 144 144 192 192 5 8 11 28 40 40 27 27 54 54 81 81 144 144 117 117 156 156 0 6 9 11 32 32 21 21 21 21 42 42 87 87 64 64 96 96 0 0 0 9 14 14 0 0 18 18 18 18 48 48 26 26 52 52 0 0 0 0 0 0 0 0 0 0 0 0 18 18 0 0 20 20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14 14 0 0 0 0 0 0 0 0 0 0 0 0 9 9 0 0 10 10 0 0 0 0 0 0 0 0 0 0 0 0 9 9 0 0 10 10 0 0 0 0 0 0 0 0 0 0 0 0 9 9 0 0 10 10 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 96 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 97 Maximum Physical Terminal Block Content 4. To complete Catalog Number, Refer to Catalog Page indicated next to the enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. Cat. Page 30128 gr 3424 gr 3425 gr 3426 gr 3427 gr 3428 gr 3429 gr 30841 gr Ex 30842 gr Ex 30843 gr Ex 30844 gr Ex 3468 gr Ex 30111 gr 3301 gr -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 7 11 15 19 56 56 36 36 36 36 108 108 196 196 159 159 212 212 7 11 15 19 56 56 36 36 36 36 108 108 147 147 159 159 212 212 5 8 11 14 42 42 27 27 27 27 81 81 111 111 120 120 160 160 0 0 10 13 18 18 0 0 24 24 48 48 99 99 70 70 105 105 0 0 0 0 15 15 0 0 0 0 20 20 54 54 29 29 58 58 0 0 0 0 0 0 0 0 0 0 0 0 21 21 0 0 23 23 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14 14 3 5 7 9 26 26 17 17 17 17 51 51 92 92 75 75 100 100 0 4 6 8 22 22 15 15 15 15 30 30 60 60 44 44 66 66 0 0 0 7 10 10 0 0 13 13 13 13 36 36 19 19 38 38 0 0 0 0 0 0 0 0 0 0 0 0 14 14 0 0 15 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11 7 11 15 19 56 56 36 36 36 36 108 108 196 196 159 159 212 212 7 11 15 19 56 56 36 36 36 36 108 108 147 147 159 159 212 212 3B–43 Enclosure Size Manufacturer - Woretz Notes: 1. See next page for more Woretz terminal blocks. 2. All quantities shown are for terminal blocks installed in vertical rows. 97 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 98 Maximum Physical Terminal Block Content 4. To complete Catalog Number, Refer to Catalog Page indicated next to the enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. Cat. Page 3302 gr 3303 gr 3304 gr 3305 gr 3306 gr 3712 gr Ex 3713 gr Ex 3713/16 gr Ex 3714 gr Ex 3715 gr Ex 30831 gr Ex 30832 gr Ex 30833 gr Ex 30834 gr Ex 3B–44 Enclosure Size Manufacturer - Woretz -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 5 8 11 14 42 42 27 27 27 27 81 81 111 111 120 120 160 160 0 0 10 13 18 18 0 0 24 24 48 48 99 99 70 70 105 105 0 0 0 0 15 15 0 0 0 0 20 20 54 54 29 29 58 58 0 0 0 0 0 0 0 0 0 0 0 0 21 21 0 0 23 23 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13 13 3 5 6 16 24 24 15 15 30 30 45 45 84 84 69 69 92 92 0 4 6 7 20 20 13 13 13 13 26 26 54 54 40 40 60 60 0 0 0 6 9 9 0 0 11 11 11 11 30 30 17 17 34 34 0 0 0 0 0 0 0 0 0 0 0 0 13 13 0 0 14 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11 3 5 7 18 26 26 17 17 34 34 51 51 92 92 75 75 100 100 0 4 6 8 22 22 15 15 15 15 30 30 60 60 44 44 66 66 0 0 0 7 10 10 0 0 13 13 13 13 36 36 19 19 38 38 0 0 0 0 0 0 0 0 0 0 0 0 14 14 0 0 15 15 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 98 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 99 Maximum Physical Terminal Block Content 4. To complete Catalog Number, Refer to Catalog Page indicated next to the enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. Cat. Page UK 2,5 N UK 3 N UK 5 N UK 6 N UK 10 N UK 16 N UK 35 UKH 50 MBK 2,5/E-EX MBK 6/E UK 3-RETURN MZB 1,5 MZB 1,5-NS 35 MZDB 1,5 MZDB 1,5-NS 35 ZFK 1,5 ZKF 2,5 ZFK 4 ZFK 6 -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 8 12 17 44 64 64 42 42 84 84 126 126 224 224 183 183 244 244 8 12 17 44 64 64 42 42 84 84 126 126 224 224 183 183 244 244 6 10 14 38 54 54 35 35 70 70 105 105 188 188 153 153 204 204 5 8 11 28 40 40 26 26 52 52 78 78 144 144 117 117 156 156 0 6 9 11 32 32 21 21 21 21 42 42 84 84 62 62 93 93 0 0 0 9 13 13 0 0 18 18 18 18 48 48 26 26 52 52 0 0 0 0 0 0 0 0 0 0 0 0 19 19 0 0 21 21 0 0 0 0 0 0 0 0 0 0 0 0 14 14 0 0 16 16 6 10 28 38 81 81 35 35 70 70 140 140 235 235 204 204 255 255 5 8 11 28 40 40 26 26 52 52 78 78 144 144 117 117 195 195 8 12 17 22 64 64 42 42 42 42 126 126 224 224 183 183 244 244 8 12 17 44 96 96 42 42 84 84 126 126 224 224 183 183 305 305 8 12 17 44 64 64 42 42 84 84 126 126 224 224 183 183 244 244 4 6 8 22 48 48 21 21 42 42 63 63 112 112 93 93 155 155 4 6 8 22 32 32 21 21 42 42 63 63 112 112 93 93 124 124 0 16 22 28 80 80 52 52 52 52 104 104 210 210 152 152 228 228 0 12 17 22 64 64 42 42 42 42 84 84 168 168 122 122 183 183 0 10 14 19 54 54 35 35 35 35 70 70 141 141 102 102 153 153 0 8 11 14 40 40 26 26 26 26 52 52 108 108 78 78 117 117 3B–45 Enclosure Size Manufacturer - Phoenix Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 99 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 100 Maximum Physical Terminal Block Content 4. To complete Catalog Number, Refer to Catalog Page indicated next to the enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. Manufacturer - Wago Cat. Page 280-991 281-691 281-991 282-691 284-691 283-691 285-691 280-698 281-693 264-120 264-220 264-125 264-225 Enclosure Size Cat. Page WK 2.5/U WK 4/U WK 6/U WKI 35/U WKN 10/U WKN 16/U WKN 35/U 3B–46 Enclosure Size Manufacturer - Wieland -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 0 13 18 22 64 64 42 42 42 42 84 84 168 168 122 122 244 244 0 11 15 19 54 54 36 36 36 36 72 72 144 144 104 104 208 208 0 11 15 19 54 54 36 36 36 36 72 72 144 144 104 104 156 156 0 8 11 15 42 42 27 27 27 27 54 54 111 111 80 80 120 120 0 6 9 12 34 34 22 22 22 22 44 44 87 87 64 64 96 96 0 0 0 10 14 14 0 0 18 18 18 18 48 48 27 27 54 54 0 0 0 0 0 0 0 0 0 0 12 12 17 17 18 18 18 18 8 13 18 22 64 64 42 42 42 42 126 126 168 168 183 183 244 244 0 11 15 19 54 54 36 36 36 36 72 72 144 144 104 104 156 156 7 11 15 40 84 84 37 37 74 74 111 111 196 196 162 162 270 270 5 8 11 28 60 60 26 26 52 52 78 78 140 140 114 114 190 190 7 11 15 40 56 56 37 37 74 74 111 111 196 196 162 162 216 216 4 6 9 24 34 34 22 22 44 44 66 66 116 116 96 96 128 128 -050503 -060604 -070704 -080804 -101006 -101008 -120604 -120605 -120805 -120806 -121206 -121208 -151506 -151508 -161206 -161208 -161606 -161608 3B–47 3B–48 3B–49 3B–50 3B–51 3B–52 3B–53 3B–54 3B–55 3B–56 3B–57 3B–58 3B–59 3B–60 3B–61 3B–62 3B–63 3B–64 7 12 17 22 66 66 43 43 43 43 129 129 232 232 189 189 252 252 6 10 14 19 54 54 36 36 36 36 108 108 192 192 159 159 212 212 4 8 11 14 40 40 27 27 27 27 81 81 108 108 117 117 156 156 0 0 0 0 0 0 0 0 0 0 0 0 29 29 0 0 31 31 0 0 8 11 16 16 0 0 21 21 42 42 87 87 62 62 93 93 0 0 0 0 13 13 0 0 0 0 18 18 48 48 26 26 52 52 0 0 0 0 0 0 0 0 0 0 0 0 18 18 0 0 19 19 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 100 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 101 3B–47 TSC Series - Screw Cover Terminal Enclosure 5''x 5''x 3'' Enclosure Material Catalog Number SS316L TSC4X6-050503 SS304 TSC4X-050503 Steel, Powder Coated TSC4-050503 Notes: 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-050503U). 2. See the end of this section for applications using multiple terminal block types. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 4. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 41 10 19 Maximum fill permitted based solely on minimum wire bending space and 16 6 13 51 electrical clearances 20 2 7 14 25 3 8 16 35 2 6 15 Additional testing required, Consult Factory 50 5 13 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 101 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 102 TSC Series - Screw Cover Terminal Enclosure 6''x 6''x 4'' 3B–48 Enclosure Material Catalog Number SS316L TSC4X6-060604 SS304 TSC4X-060604 Steel, Powder Coated TSC4-060604 Notes: 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-060604U). 2. See the end of this section for applications using multiple terminal block types. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 4. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 48 10 23 Maximum fill permitted based solely on minimum wire bending space and 16 8 15 60 electrical clearances 20 3 9 17 25 9 9 19 35 2 7 18 Additional testing required, Consult Factory 50 1 6 15 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 102 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 103 3B–49 TSC Series - Screw Cover Terminal Enclosure 7''x 7''x 4'' Enclosure Material Catalog Number SS316L TSC4X6-070704 SS304 TSC4X-070704 Steel, Powder Coated TSC4-070704 Notes: Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 51 10 25 Maximum fill permitted based solely on minimum wire bending space and 16 8 16 64 electrical clearances 20 3 9 18 25 4 10 20 35 3 8 20 Additional testing required, Consult Factory 50 1 6 16 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-070704U). Qualifying Enclosure for Increased Safety Certification 2. See the end of this section for applications using multiple terminal block types. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 2. Find the Current (amperage) you intend to apply to the conductor. 4. For Conduit/Cable entry spacings refer to the end of this section. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 103 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 104 TSC Series - Screw Cover Terminal Enclosure 8''x 8''x 4'' 3B–50 Enclosure Material Catalog Number SS316L TSC4X6-080804 SS304 TSC4X-080804 Steel, Powder Coated TSC4-080804 Notes: Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 55 10 27 Maximum fill permitted based solely on minimum wire bending space and 16 9 17 69 electrical clearances 20 3 10 20 25 5 11 22 35 3 8 21 Additional testing required, Consult Factory 50 1 7 17 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-080804U). Qualifying Enclosure for Increased Safety Certification 2. See the end of this section for applications using multiple terminal block types. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 2. Find the Current (amperage) you intend to apply to the conductor. 4. For Conduit/Cable entry spacings refer to the end of this section. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 104 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 105 3B–51 TSC Series - Screw Cover Terminal Enclosure 10''x 10''x 6'' Enclosure Material Catalog Number SS316L TSC4X6-101006 SS304 TSC4X-101006 Steel, Powder Coated TSC4-101006 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-101006-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-101006U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 77 10 37 Maximum fill permitted based solely on minimum wire bending space and 16 13 25 97 electrical clearances 20 5 14 28 25 7 16 30 35 4 12 30 Additional testing required, Consult Factory 50 1 9 24 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 105 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 106 TSC Series - Screw Cover Terminal Enclosure 10''x 10''x 8'' 3B–52 Enclosure Material Catalog Number SS316L TSC4X6-101008 SS304 TSC4X-101008 Steel, Powder Coated TSC4-101008 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-101008-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-101008U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 92 10 45 Maximum fill permitted based solely on minimum wire bending space and 16 15 30 116 electrical clearances 20 6 17 33 25 8 19 36 35 5 14 35 Additional testing required, Consult Factory 50 2 11 29 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 106 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 107 3B–53 TSC Series - Screw Cover Terminal Enclosure 12''x 6''x 4'' Enclosure Material Catalog Number SS316L TSC4X6-120604 SS304 TSC4X-120604 Steel, Powder Coated TSC4-120604 Notes: Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 52 10 25 Maximum fill permitted based solely on minimum wire bending space and 16 8 17 66 electrical clearances 20 3 9 19 25 4 10 20 35 3 8 20 Additional testing required, Consult Factory 50 1 6 16 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-120604U). Qualifying Enclosure for Increased Safety Certification 2. See the end of this section for applications using multiple terminal block types. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 2. Find the Current (amperage) you intend to apply to the conductor. 4. For Conduit/Cable entry spacings refer to the end of this section. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 107 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 108 TSC Series - Screw Cover Terminal Enclosure 12''x 6''x 5'' 3B–54 Enclosure Material Catalog Number SS316L TSC4X6-120605 SS304 TSC4X-120605 Steel, Powder Coated TSC4-120605 Notes: Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 59 10 29 Maximum fill permitted based solely on minimum wire bending space and 16 10 19 74 electrical clearances 20 4 11 21 25 5 12 23 35 3 9 23 Additional testing required, Consult Factory 50 1 7 19 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-120605U). Qualifying Enclosure for Increased Safety Certification 2. See the end of this section for applications using multiple terminal block types. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 2. Find the Current (amperage) you intend to apply to the conductor. 4. For Conduit/Cable entry spacings refer to the end of this section. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 108 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 109 3B–55 TSC Series - Screw Cover Terminal Enclosure 12''x 8''x 5'' Enclosure Material Catalog Number SS316L TSC4X6-120805 SS304 TSC4X-120805 Steel, Powder Coated TSC4-120805 Notes: 1. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-120805U). Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 67 10 32 Maximum fill permitted based solely on minimum wire bending space and 16 11 21 84 electrical clearances 20 4 12 24 25 6 14 26 35 4 10 26 Additional testing required, Consult Factory 50 1 8 21 Qualifying Enclosure for Increased Safety Certification 2. See the end of this section for applications using multiple terminal block types. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 2. Find the Current (amperage) you intend to apply to the conductor. 4. For Conduit/Cable entry spacings refer to the end of this section. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 109 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 110 TSC Series - Screw Cover Terminal Enclosure 12''x 8''x 6'' 3B–56 Enclosure Material Catalog Number SS316L TSC4X6-120806 SS304 TSC4X-120806 Steel, Powder Coated TSC4-120806 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-120806-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-120806U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 74 10 36 Maximum fill permitted based solely on minimum wire bending space and 16 12 24 93 electrical clearances 20 5 14 27 25 6 15 29 35 4 11 28 Additional testing required, Consult Factory 50 1 9 23 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 110 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 111 3B–57 TSC Series - Screw Cover Terminal Enclosure 12''x 12''x 6'' Enclosure Material Catalog Number SS316L TSC4X6-121206 SS304 TSC4X-121206 Steel, Powder Coated TSC4-121206 Notes: Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 85 10 41 Maximum fill permitted based solely on minimum wire bending space and 16 14 27 107 electrical clearances 20 5 16 31 25 7 17 33 35 5 13 33 Additional testing required, Consult Factory 50 1 10 27 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-121206-ABCD). Qualifying Enclosure for Increased Safety Certification 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-121206U). 2. Find the Current (amperage) you intend to apply to the conductor. 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 111 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 112 TSC Series - Screw Cover Terminal Enclosure 12''x 12''x 8'' 3B–58 Enclosure Material Catalog Number SS316L TSC4X6-121208 SS304 TSC4X-121208 Steel, Powder Coated TSC4-121208 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-121208-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-121208U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 100 10 48 Maximum fill permitted based solely on minimum wire bending space and 16 16 32 125 electrical clearances 20 7 19 36 25 9 20 39 35 6 15 38 Additional testing required, Consult Factory 50 2 12 32 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 112 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 113 3B–59 TSC Series - Screw Cover Terminal Enclosure 15''x 15''x 6'' Enclosure Material Catalog Number SS316L TSC4X6-151506 SS304 TSC4X-151506 Steel, Powder Coated TSC4-151506 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-151506-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-151506U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 96 10 46 Maximum fill permitted based solely on minimum wire bending space and 16 16 31 121 electrical clearances 20 6 18 35 25 8 19 38 35 5 15 37 Additional testing required, Consult Factory 50 2 12 30 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 113 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 114 TSC Series - Screw Cover Terminal Enclosure 15''x 15''x 8'' 3B–60 Enclosure Material Catalog Number SS316L TSC4X6-151508 SS304 TSC4X-151508 Steel, Powder Coated TSC4-151508 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-151508-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-151508U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 111 10 54 Maximum fill permitted based solely on minimum wire bending space and 16 18 36 139 electrical clearances 20 7 21 40 25 10 23 44 35 6 17 43 Additional testing required, Consult Factory 50 2 14 35 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 114 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 115 3B–61 TSC Series - Screw Cover Terminal Enclosure 16''x 12''x 6'' Enclosure Material Catalog Number SS316L TSC4X6-161206 SS304 TSC4X-161206 Steel, Powder Coated TSC4-161206 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-161206-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-161206U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 90 10 44 Maximum fill permitted based solely on minimum wire bending space and 16 15 29 113 electrical clearances 20 6 17 33 25 8 18 36 35 5 14 35 Additional testing required, Consult Factory 50 2 11 29 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 115 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 116 TSC Series - Screw Cover Terminal Enclosure 16''x 12''x 8'' 3B–62 Enclosure Material Catalog Number SS316L TSC4X6-161208 SS304 TSC4X-161208 Steel, Powder Coated TSC4-161208 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-161208-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-161208U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 105 10 51 Maximum fill permitted based solely on minimum wire bending space and 16 17 34 132 electrical clearances 20 7 20 38 25 9 21 41 35 6 16 40 Additional testing required, Consult Factory 50 2 13 33 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 116 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 117 3B–63 TSC Series - Screw Cover Terminal Enclosure 16''x 16''x 6'' Enclosure Material Catalog Number SS316L TSC4X6-161606 SS304 TSC4X-161606 Steel, Powder Coated TSC4-161606 Notes: 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-161606-ABCD). 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-161606U). 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 100 10 48 Maximum fill permitted based solely on minimum wire bending space and 16 16 32 125 electrical clearances 20 7 19 36 25 9 20 39 35 6 15 38 Additional testing required, Consult Factory 50 2 12 32 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 117 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 118 TSC Series - Screw Cover Terminal Enclosure 16''x 16''x 8'' 3B–64 Enclosure Material Catalog Number SS316L TSC4X6-161608 SS304 TSC4X-161608 Steel, Powder Coated TSC4-161608 Notes: Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm5) (amps) 1.5 2.5 4 6 10 16 8 115 10 56 Maximum fill permitted based solely on minimum wire bending space and 16 19 37 144 electrical clearances 20 8 21 42 25 10 23 45 35 7 18 44 Additional testing required, Consult Factory 50 2 14 36 1. For Gland Plates add suffixes -A (top), -B (bottom), -C (left), -D (right) immediately following the catalog number (i.e. TSC4X6-161608-ABCD). Qualifying Enclosure for Increased Safety Certification 2. For Empty Enclosures add U immediately following the catalog number (i.e. TSC4X6-161608U). 2. Find the Current (amperage) you intend to apply to the conductor. 3. See the end of this section for applications using multiple terminal block types. 4. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 5. For Conduit/Cable entry spacings refer to the end of this section. 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 118 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 119 Qualifying Enclosures for Increased Safety Certification with Multiple Terminal Block Types Current (amps) 8 10 16 20 25 35 50 1.5 90 44 15 6 Maximum Terminal Block Wire Size (mm5) 2.5 4 6 10 29 17 8 Additional Testing Required, Consult Factory 113 33 18 5 16 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 36 14 2 35 11 29 Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below. Example: Current Number % of Maximum Terminal Population 2.5 16 7 (of 29) = 24% 4 20 16 (of 33) = 48% 10 35 9 (of 35) = 26% Total = 98% < 3B–65 Conductor Size 100% Notes: 1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor size and the continuous current for the designated enclosures. 2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and manufacturer's instructions. 3. Grounding terminals, bridges and grounding conductors are not counted. 4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges. 5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals and conductors should be considered. 6. Combinations not covered by the above tables may be permitted if they are determined acceptable by test. 119 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 120 Conduit/Cable & Wire Bending Guidelines Table A - Minimum Spacing Between Centers of Conduit or Cable Entries 3B–66 SIZE NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 NPT METRIC -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 1/16 ~ 3/8 -- 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 1-1/8 [29mm] 1/2 M16 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 3/4 M20 4-1/2 [115mm] 3-3/4 [96mm] 3-1/2 3-1/8 [89mm] [80mm] 2-3/4 [70mm] 2-1/2 [64mm] 2-1/8 [54mm] 2 [51mm] 1-3/4 [45mm] 1-1/2 [38mm] 1 M25 4-5/8 [118mm] 3-7/8 [99mm] 3-5/8 3-1/4 [92mm] [83mm] 2-7/8 [74mm] 2-3/4 [70mm] 2-1/4 [58mm] 2-1/8 [54mm] 1-7/8 [48mm] 1-1/4 M32 4-7/8 [124mm] 4-1/8 [105mm] 3-7/8 [99mm 3-1/2 [89mm] 3-1/8 [80mm] 2-7/8 [74mm] 2-1/2 [64mm] 2-3/8 [61mm] 1-1/2 M40 5 [127mm] 4-1/4 4 3-5/8 [108mm] [102mm] [92mm] 3-1/4 [83mm] 3 [77mm] 2-5/8 [68mm] 2 M50 5-3/8 [137mm] 4-3/4 4-1/2 4 3-5/8 [121mm] [115mm] [102mm] [92mm] 3-3/8 [86mm] 2-1/2 M63 5-1/2 [140mm] 4-7/8 4-5/8 4-1/4 3-7/8 [124mm] [118mm] [108mm] [99mm] 3 M75 5-7/8 [150mm] 5-1/4 5 4-5/8 [134mm] [127mm] [118mm] 3-1/2 -- 6-1/4 [159mm] 5-3/4 5-1/2 [147mm] [140mm] 4 -- 6-7/8 [175mm] 6 [153mm] 5 -- 7-3/8 [188mm] This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and condition under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 2-13/16 [72mm] 2-1/4 [58mm] 2 [51mm] 1-3/16 [31mm] 1 [26mm] 7/8 [23mm] 11/16 [18mm] 9/16 [14mm] 1/2 [13mm] 1/2 [13mm] METRIC 1-3/4 1-7/16 [45mm] [37mm] Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls AWG 16 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0 250 350 400 500 mm sq. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1-1/2 1-1/2 1-1/2 1-1/2 2 3 3-1/2 5-1/2 6 6-1/2 7 8-1/2 10 12 13 14 [38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm] Notes: 1. The distances in Table A are recommended minimum distances between centers of conduit and cable gland entries. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. entries to the edge of an opening or inside wall of box. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 3. The distances in Table C are the minimum wire bending space requirements between terminals, partitions, or inside walls. 2. The distances in Table B are recommended minimum distances between center of conduit and cable gland 120 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 121 TFG Series Close-up Plugs: Any unused entries must be plugged with a Certified Close-Up Plug. Adalet can provide close-up plugs in various styles and materials. Please indicate on the sketch or provide detailed information of holes to be plugged. Enclosure Labeling: Adalet can provide additional enclosure labeling with custom silk screening or various colors of Lamacoid™ nameplates. Please provide detailed information of the logo or text required. 18 Enclosure Sizes 3B–67 Breather Drains: Available in 18 sizes, from 6”x4”x4” (model 060406) to (model 201610). Breather Drains can be provided per customer request. They are available in Brass or Stainless Steel 316L. Please indicate on a sketch or provide detailed information for locations. Construction • Compression Molded, Fiberglass Reinforced Polyester • Memory Retaining, Poured In Place Silicone Gasket • Molded Mounting Feet with 5/16” Clearance Holes Grounding Busbars: • Captive Cover Screws • Universal Rail Mounting System Some applications might require grounding points to be terminated in the enclosure. With the use of a Ground Busbar System this can be accomplished, consult factory for options. Options Hinged Cover: Mounting Pans: A stainless steel piano type hinge is available by adding an H to the end of the catalog string. (i.e. TFG-201407H) As an alternative to the universal rail mounting system, mounting pans are available in steel/powder coated, stainless steel, and aluminum. Please indicate when requesting quote. Earthing Stud Assembly: An Internal/External Earthing Stud can be provided upon request. Please specify on the request for quote. Terminal Strip Assemblies: Various options (i.e. marking tags, protective covers, jumpers, partitions,..) are available. Please provide detailed information requesting quote. Conduit/Cable Entries: Entries can be provided per a customer sketch or with detailed information on the entry locations. Please refer to Entry Spacing Tables at the end of the Increased Safety Section in the CENELEC Product Catalog. Note: This information is important and could affect the size of the enclosure you selected. 121 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 122 TFG Series - Screw Cover Terminal Enclosure General Information Adalet's TFG Series of Increased Safety Terminal Enclosures are compression molded from a fiberglass reinforced polyester resin. Available in (18) sizes with integral mounting feet and a minimum wall section thickness of 3mm, these enclosures are ideal for indoor and outdoor areas where dampness and highly corrosive atmospheres are present. Suitable for Petrochemical, Water Treatment, Food Processing, Coating, Salts and Chemical applications, they are also ideal for installation where weight is a prime factor in enclosure selection. Enclosure Certifications with Terminals 3B–68 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Empty Enclosure Certifications 0539 II 2GD EEx e II Ex e II Class I, Zone 1, AEx e II Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 Working Voltage Terminal Blocks Various manufacturers Material Enclosure Mounting Pan Gasket Cover Lid Fixing All Types Enclosure Mounting All Types Grounding All Types Impact Resistant All Types Ambient Temperature Range All Types ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 D ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 1100 Volts Maximum EEx e type with wire sizes 1.5mm up to 16mm Fiberglass Reinforced Polyester - 3mm Wall Section Thickness .08 Aluminum, Steel - Painted, or Stainless Steel Silicone Captive Cover Screws - Stainless Steel External mounting feet with .31'' clearance holes Grounding Terminal Block (sized for the largest conductor used) 7 Nm to EN50014/EN50019 -40°C to +70°C to EN50014 D 122 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 123 TFG Series - Quick Selector 4. To complete catalog number, refer to catalog page indicated next to enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block size for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 1. Using the table below, refer to the Heat Dissipation Table found on the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. Maximum Physical Terminal Block Content Enclosure Catalog Sizes Page 1.5mm 2.5mm 4mm -060404 3B–78 0 9 7 0 0 0 0 0 0 -060406 3B–79 0 9 7 0 0 0 0 0 0 -060604 3B–80 10 9 7 6 5 0 0 0 0 -060606 3B–81 10 9 7 6 5 0 0 0 0 -080604 3B–82 20 16 15 12 10 0 0 0 0 -080606 3B–83 20 16 15 12 10 0 0 0 0 -100804 3B–84 60 25 23 36 15 12 0 0 0 -100806 3B–85 60 25 23 36 15 12 0 0 0 -121005 3B–86 80 66 60 50 40 17 0 0 0 -121006 3B–87 80 66 60 50 40 17 0 0 0 -141206 3B–88 150 123 114 93 50 21 0 0 0 -141207 3B–89 150 123 114 93 50 21 0 0 0 -161406 3B–90 183 150 138 148 90 50 19 0 0 -161407 3B–91 183 150 138 148 90 50 19 0 0 -181608 3B–92 284 232 212 172 105 58 22 17 16 -181610 3B–93 284 232 212 172 105 58 22 17 16 -201608 3B–94 324 264 244 200 120 68 25 20 18 -201610 3B–95 324 264 244 200 120 68 25 20 18 10mm 16mm 35mm 50mm 70mm 3B–69 6mm Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 2. Quantities shown above are for Adalet supplied standard terminal blocks. 123 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 124 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete catalog number, refer to the catalog page indicated next to enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 2. Refer to catalog page for Heat Dissipation Tables. Cat. Page MA2,5/5… MA2,5/5.1… M4/6… M6/8… M10/10… M16/12… M35/16… M4/6.H… M1,5/6.HH MTC6 MA2,5/5.SNB M4/6.SN… M4/6.SNB 3B–70 Enclosure Size Manufacturer - Entrelec -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 9 9 19 19 58 58 78 78 147 147 177 177 276 276 316 316 0 0 9 9 19 19 58 58 78 78 147 147 177 177 276 276 316 316 0 0 8 8 16 16 48 48 66 66 123 123 150 150 232 232 264 264 0 0 6 6 12 12 36 36 50 50 93 93 111 111 176 176 200 200 0 0 4 4 9 9 15 15 40 40 50 50 90 90 105 105 120 120 0 0 0 0 0 0 12 12 16 16 20 20 50 50 58 58 66 66 0 0 0 0 0 0 0 0 0 0 0 0 18 18 22 22 25 25 0 0 8 8 16 16 24 24 66 66 82 82 150 150 232 232 264 264 0 0 8 8 16 16 24 24 66 66 82 82 150 150 174 174 198 198 0 0 8 8 16 16 48 48 66 66 123 123 150 150 232 232 264 264 0 0 9 9 19 19 58 58 78 78 147 147 177 177 276 276 316 316 0 0 8 8 16 16 48 48 66 66 123 123 150 150 232 232 264 264 0 0 8 8 16 16 48 48 66 66 123 123 150 150 232 232 264 264 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 124 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 125 Maximum Physical Terminal Block Content 4. To complete catalog number, refer to the catalog page indicated next to enclosure size you selected. Enclosure Selection 1. Using the table below, select the terminal block type for your application. 5. For Enclosure Selection using specific Terminal Block Manufacturers refer to following pages. 2. Follow the column down until you find the quantity required for your application. For Increased Safety Applications 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size (H X W) for your application. 2. Refer to catalog page for Heat Dissipation Tables. DR4/6… M35/26.FF M70/31.FF M35/26.AF M70.31.AF D4/6…ADO D4/6.ADO.T… D4/6.ADO… D6/8…ADO D6/8.ADO… 0 0 6 6 12 12 36 36 50 50 93 93 111 111 176 176 200 200 0 0 6 6 12 12 18 18 50 50 62 62 111 111 132 132 150 150 0 0 9 9 17 17 50 50 102 102 168 168 204 204 295 295 335 335 0 0 0 0 0 0 0 0 7 7 9 9 11 11 13 13 15 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11 13 13 0 0 0 0 0 0 0 0 7 7 9 9 11 11 13 13 15 15 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11 13 13 0 0 8 8 16 16 24 24 66 66 123 123 150 150 232 232 264 264 0 0 8 8 16 16 24 24 66 66 123 123 150 150 232 232 264 264 0 0 8 8 16 16 24 24 66 66 123 123 150 150 232 232 264 264 0 0 6 6 12 12 18 18 50 50 93 93 111 111 176 176 200 200 0 0 6 6 12 12 18 18 50 50 93 93 111 111 176 176 200 200 3B–71 M4/8.SN 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 M6/8.SNB -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 Cat. Page Enclosure Size Manufacturer - Entrelec Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 125 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 126 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete catalog number, refer to catalog page indicated next to the enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to catalog page for Heat Dissipation Tables. Cat. Page WDU2.5N WDU2.5 WDU4 WDU6 WDU10 WDU16 WDU35 WWF35 ZDU2.5 ZDU4 ZDU6 AKZ2.5 AKZ4 3B–72 Enclosure Size Manufacturer - Weidmuller -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 10 10 20 20 60 60 80 80 150 150 183 183 284 284 324 324 0 0 10 10 20 20 30 30 80 80 100 100 183 183 213 213 243 243 0 0 10 10 20 20 30 30 80 80 100 100 183 183 213 213 243 243 0 0 6 6 12 12 19 19 50 50 64 64 114 114 135 135 153 153 0 0 0 0 0 0 15 15 20 20 50 50 60 60 105 105 123 123 0 0 0 0 0 0 0 0 17 17 21 21 50 50 58 58 68 68 0 0 0 0 0 0 0 0 0 0 0 0 19 19 22 22 25 25 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 12 14 14 0 0 10 10 20 20 30 30 80 80 100 100 180 180 210 210 240 240 0 0 8 8 16 16 25 25 66 66 82 82 150 150 174 174 198 198 0 0 6 6 12 12 18 18 50 50 62 62 111 111 129 129 150 150 9 9 9 9 19 19 60 60 120 120 200 200 300 300 350 350 400 400 7 7 7 7 16 16 48 48 96 96 164 164 245 245 285 285 330 330 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 126 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 127 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete catalog number, refer to catalog page indicated next to the enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to catalog page for Heat Dissipation Tables. Cat. Page AKE2.5 AKE4 SAK2.5 SAK4 SAK6N SAK10 SAK16 SAK35N SAK70 SAKG 28 I SAKG 28 II SAKG 28 III -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 9 9 19 19 60 60 120 120 200 200 240 240 350 350 400 400 0 0 7 7 14 14 44 44 87 87 111 111 176 176 255 255 295 295 0 0 8 8 16 16 25 25 66 66 123 123 150 150 232 232 264 264 0 0 7 7 15 15 23 23 60 60 114 114 138 138 212 212 244 244 0 0 6 6 12 12 36 36 50 50 93 93 148 148 172 172 200 200 0 0 5 5 10 10 15 15 40 40 50 50 90 90 105 105 120 120 0 0 0 0 0 0 12 12 17 17 21 21 50 50 58 58 68 68 0 0 0 0 0 0 0 0 0 0 0 0 19 19 22 22 25 25 0 0 0 0 0 0 0 0 0 0 0 0 0 0 16 16 18 18 0 0 0 0 0 0 0 0 0 0 0 0 10 10 11 11 13 13 0 0 0 0 0 0 0 0 0 0 0 0 10 10 11 11 13 13 0 0 0 0 0 0 0 0 0 0 0 0 10 10 11 11 13 13 3B–73 Enclosure Size Manufacturer - Weidmuller Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 127 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 128 Maximum Physical Terminal Block Content Manufacturer - Woretz Enclosure Selection 4. To complete catalog number, refer to catalog page indicated next to the enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to catalog page for Heat Dissipation Tables. Cat. Page 30128 gr 3424 gr 3425 gr 3426 gr 3427 gr 3428 gr 3429 gr 30841 gr Ex 30842 gr Ex 30843 gr Ex 30844 gr Ex 3468 gr Ex 30111 gr 3301 gr 3B–74 Enclosure Size Manufacturer - Woretz -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 8 8 17 17 25 25 68 68 126 126 153 153 236 236 272 272 0 0 8 8 17 17 25 25 68 68 126 126 153 153 236 236 272 272 0 0 6 6 12 12 19 19 50 50 96 96 114 114 176 176 204 204 0 0 0 0 0 0 17 17 22 22 56 56 68 68 117 117 135 135 0 0 0 0 0 0 0 0 18 18 23 23 54 54 64 64 74 74 0 0 0 0 0 0 0 0 0 0 0 0 21 21 25 25 29 29 0 0 0 0 0 0 0 0 0 0 0 0 0 0 15 15 17 17 0 0 4 4 8 8 12 12 32 32 60 60 72 72 112 112 128 128 0 0 3 3 7 7 10 10 28 28 34 34 63 63 72 72 84 84 0 0 0 0 0 0 9 9 12 12 15 15 36 36 42 42 48 48 0 0 0 0 0 0 0 0 0 0 0 0 14 14 17 17 19 19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 12 14 14 0 0 8 8 17 17 25 25 68 68 126 126 153 153 236 236 272 272 0 0 8 8 17 17 25 25 68 68 126 126 153 153 236 236 272 272 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 128 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 129 Maximum Physical Terminal Block Content Manufacturer - Woretz Enclosure Selection 4. To complete catalog number, refer to catalog page indicated next to the enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to catalog page for Heat Dissipation Tables. Cat. Page 3302 gr 3303 gr 3304 gr 3305 gr 3306 gr 3712 gr Ex 3713 gr Ex 3713/16 gr Ex 3714 gr Ex 3715 gr Ex 30831 gr Ex 30832 gr Ex 30833 gr Ex 30834 gr Ex -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 6 6 12 12 19 19 50 50 96 96 114 114 176 176 204 204 0 0 0 0 0 0 17 17 22 22 56 56 68 68 117 117 135 135 0 0 0 0 0 0 0 0 18 18 23 23 54 54 64 64 74 74 0 0 0 0 0 0 0 0 0 0 0 0 21 21 25 25 29 29 0 0 0 0 0 0 0 0 0 0 0 0 0 0 15 15 17 17 0 0 3 3 7 7 22 22 28 28 54 54 66 66 100 100 116 116 0 0 3 3 6 6 9 9 24 24 32 32 57 57 66 66 75 75 0 0 0 0 0 0 8 8 10 10 13 13 32 32 36 36 42 42 0 0 0 0 0 0 0 0 0 0 0 0 14 14 16 16 18 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12 12 14 14 0 0 4 4 8 8 24 24 32 32 60 60 72 72 112 112 128 128 0 0 3 3 7 7 10 10 28 28 34 34 63 63 72 72 84 84 0 0 0 0 0 0 9 9 12 12 15 15 36 36 42 42 48 48 0 0 0 0 0 0 0 0 0 0 0 0 14 14 17 17 19 19 3B–75 Enclosure Size Manufacturer - Woretz Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 129 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 130 Maximum Physical Terminal Block Content Manufacturer - Phoenix Enclosure Selection 4. To complete catalog number, refer to catalog page indicated next to the enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to catalog page for Heat Dissipation Tables. Cat. Page UK 2,5 N UK 3 N UK 5 N UK 6 N UK 10 N UK 16 N UK 35 UKH 50 MBK 2,5/E-EX MBK 6/E UK 3-RETURN MZB 1,5 MZB 1,5-NS 35 MZDB 1,5 MZDB 1,5-NS 35 ZFK 1,5 ZKF 2,5 ZFK 4 ZFK 6 3B–76 Enclosure Size Manufacturer - Phoenix -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 9 9 19 19 58 58 78 78 144 144 174 174 272 272 312 312 0 0 9 9 19 19 58 58 78 78 144 144 174 174 272 272 312 312 0 0 8 8 16 16 48 48 64 64 123 123 147 147 228 228 260 260 0 0 6 6 12 12 36 36 48 48 93 93 111 111 172 172 196 196 0 0 5 5 10 10 14 14 38 38 48 48 87 87 102 102 117 117 0 0 0 0 0 0 12 12 16 16 20 20 50 50 58 58 66 66 0 0 0 0 0 0 0 0 0 0 0 0 20 20 23 23 26 26 0 0 0 0 0 0 0 0 0 0 0 0 0 0 17 17 20 20 8 8 8 8 16 16 48 48 96 96 164 164 245 245 285 285 325 325 0 0 6 6 12 12 36 36 48 48 93 93 148 148 215 215 245 245 0 0 9 9 19 19 29 29 78 78 144 144 174 174 272 272 312 312 0 0 9 9 19 19 58 58 117 117 144 144 232 232 340 340 390 390 0 0 9 9 19 19 58 58 78 78 144 144 174 174 272 272 312 312 0 0 4 4 9 9 28 28 57 57 72 72 116 116 170 170 195 195 0 0 4 4 9 9 28 28 38 38 72 72 87 87 136 136 156 156 0 0 12 12 24 24 36 36 96 96 120 120 216 216 252 252 291 291 0 0 9 9 19 19 29 29 78 78 96 96 174 174 204 204 234 234 0 0 8 8 16 16 24 24 64 64 82 82 147 147 171 171 195 195 0 0 6 6 12 12 18 18 48 48 62 62 111 111 129 129 147 147 Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 130 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 131 Maximum Physical Terminal Block Content Enclosure Selection 4. To complete catalog number, refer to catalog page indicated next to the enclosure size you selected. 1. Using the table below, select the terminal block type for your application. For Increased Safety Applications 2. Follow the column down until you find the quantity required for your application. 1. Using the table below, find the catalog page for the enclosure size you selected. 3. Follow the row left until you reach the Enclosure Size column. This is the minimum enclosure size for your application. 2. Refer to catalog page for Heat Dissipation Tables. Manufacturer - Wago Cat. Page 280-991 281-691 281-991 282-691 284-691 283-691 285-691 280-698 281-693 264-120 264-220 264-125 264-225 Enclosure Size Cat. Page WK 2.5/U WK 4/U WK 6/U WKI 35/U WKN 10/U WKN 16/U WKN 35/U -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 10 10 19 19 29 29 78 78 96 96 174 174 268 268 308 308 0 0 8 8 17 17 25 25 66 66 82 82 147 147 232 232 264 264 0 0 8 8 17 17 25 25 66 66 82 82 147 147 174 174 198 198 0 0 6 6 13 13 19 19 50 50 64 64 114 114 132 132 153 153 0 0 5 5 10 10 15 15 40 40 50 50 60 60 105 105 120 120 0 0 0 0 0 0 12 12 17 17 21 21 50 50 58 58 68 68 0 0 0 0 0 0 0 0 0 0 14 14 17 17 20 20 23 23 0 0 10 10 19 19 29 29 78 78 144 144 174 174 268 268 308 308 0 0 8 8 17 17 25 25 66 66 82 82 147 147 174 174 198 198 0 0 8 8 17 17 50 50 102 102 126 126 204 204 295 295 340 340 0 0 6 6 12 12 36 36 72 72 90 90 144 144 210 210 240 240 0 0 8 8 17 17 50 50 68 68 126 126 204 204 236 236 272 272 0 0 5 5 10 10 30 30 40 40 75 75 120 120 140 140 160 160 -060404 -060406 -060604 -060606 -080604 -080606 -100804 -100806 -121005 -121006 -141206 -141207 -161406 -161407 -181608 -181610 -201608 -201610 3B–78 3B–79 3B–80 3B–81 3B–82 3B–83 3B–84 3B–85 3B–86 3B–87 3B–88 3B–89 3B–90 3B–91 3B–92 3B–93 3B–94 3B–95 0 0 9 9 19 19 29 29 80 80 150 150 180 180 280 280 320 320 0 0 8 8 16 16 25 25 66 66 123 123 150 150 232 232 268 268 0 0 6 6 12 12 18 18 50 50 93 93 111 111 176 176 200 200 0 0 0 0 0 0 0 0 0 0 0 0 30 30 35 35 40 40 0 0 0 0 0 0 14 14 20 20 50 50 60 60 105 105 120 120 0 0 0 0 0 0 0 0 16 16 20 20 50 50 58 58 66 66 0 0 0 0 0 0 0 0 0 0 0 0 18 18 22 22 25 25 3B–77 Enclosure Size Manufacturer - Wieland Notes: 1. All quantities shown are for terminal blocks installed in vertical rows. 131 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 132 TFG Series - Screw Cover Terminal Enclosure 6''x 4''x 4'' 3B–78 Enclosure Type Catalog Number Chained, Lift-Off TFG-060404 Hinged TFG-060404H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 52 10 25 Maximum fill permitted based solely on minimum wire bending space and 16 8 16 65 electrical clearances 20 3 9 19 25 4 10 20 35 3 8 20 Additional testing required, Consult Factory 50 1 6 16 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 132 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 133 3B–79 TFG Series - Screw Cover Terminal Enclosure 6''x 4''x 6'' Enclosure Type Catalog Number Chained, Lift-Off TFG-060406 Hinged TFG-060406H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 63 10 30 Maximum fill permitted based solely on minimum wire bending space and 16 10 20 79 electrical clearances 20 4 12 23 25 5 13 25 35 3 9 24 Additional testing required, Consult Factory 50 1 8 20 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 133 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 134 TFG Series - Screw Cover Terminal Enclosure 6''x 6''x 4'' 3B–80 Enclosure Type Catalog Number Chained, Lift-Off TFG-060604 Hinged TFG-060604H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 57 10 28 Maximum fill permitted based solely on minimum wire bending space and 16 9 18 72 electrical clearances 20 4 10 21 25 5 11 23 35 3 9 22 Additional testing required, Consult Factory 50 1 7 18 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 134 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 135 3B–81 TFG Series - Screw Cover Terminal Enclosure 6''x 6''x 6'' Enclosure Type Catalog Number Chained, Lift-Off TFG-060606 Hinged TFG-060606H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 69 10 33 Maximum fill permitted based solely on minimum wire bending space and 16 11 22 86 electrical clearances 20 4 13 25 25 6 14 27 35 4 10 26 Additional testing required, Consult Factory 50 1 8 22 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 135 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 136 TFG Series - Screw Cover Terminal Enclosure 8''x 6''x 4'' 3B–82 Enclosure Type Catalog Number Chained, Lift-Off TFG-080604 Hinged TFG-080604H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 60 10 29 Maximum fill permitted based solely on minimum wire bending space and 16 10 19 75 electrical clearances 20 4 11 22 25 5 12 24 35 3 9 23 Additional testing required, Consult Factory 50 1 7 19 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 136 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 137 3B–83 TFG Series - Screw Cover Terminal Enclosure 8''x 6''x 6'' Enclosure Type Catalog Number Chained, Lift-Off TFG-080606 Hinged TFG-080606H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 71 10 34 Maximum fill permitted based solely on minimum wire bending space and 16 11 23 89 electrical clearances 20 4 13 26 25 6 14 28 35 4 11 27 Additional testing required, Consult Factory 50 1 9 22 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 137 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 138 TFG Series - Screw Cover Terminal Enclosure 10''x 8''x 4'' 3B–84 Enclosure Type Catalog Number Chained, Lift-Off TFG-100804 Hinged TFG-100804H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 64 10 31 Maximum fill permitted based solely on minimum wire bending space and 16 10 20 80 electrical clearances 20 4 12 23 25 5 13 25 35 3 10 24 Additional testing required, Consult Factory 50 1 8 20 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 138 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 139 3B–85 TFG Series - Screw Cover Terminal Enclosure 10''x 8''x 6'' Enclosure Type Catalog Number Chained, Lift-Off TFG-100806 Hinged TFG-100806H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 82 10 39 Maximum fill permitted based solely on minimum wire bending space and 16 13 26 102 electrical clearances 20 5 15 29 25 7 16 32 35 5 12 31 Additional testing required, Consult Factory 50 1 10 26 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 139 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 140 TFG Series - Screw Cover Terminal Enclosure 12''x 10''x 5'' 3B–86 Enclosure Type Catalog Number Chained, Lift-Off TFG-121005 Hinged TFG-121005H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 79 10 38 Maximum fill permitted based solely on minimum wire bending space and 16 13 25 99 electrical clearances 20 5 15 28 25 7 16 31 35 4 12 30 Additional testing required, Consult Factory 50 1 10 25 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 140 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 141 3B–87 TFG Series - Screw Cover Terminal Enclosure 12''x 10''x 6'' Enclosure Type Catalog Number Chained, Lift-Off TFG-121006 Hinged TFG-121006H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 89 10 43 Maximum fill permitted based solely on minimum wire bending space and 16 15 29 112 electrical clearances 20 6 16 32 25 8 18 35 35 5 14 34 Additional testing required, Consult Factory 50 4 11 28 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 141 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 142 TFG Series - Screw Cover Terminal Enclosure 14''x 12''x 6'' 3B–88 Enclosure Type Catalog Number Chained, Lift-Off TFG-141206 Hinged TFG-141206H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 94 10 46 Maximum fill permitted based solely on minimum wire bending space and 16 15 30 118 electrical clearances 20 6 17 34 25 8 19 37 35 5 14 36 Additional testing required, Consult Factory 50 2 12 30 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 142 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 143 3B–89 TFG Series - Screw Cover Terminal Enclosure 14''x 12''x 7'' Enclosure Type Catalog Number Chained, Lift-Off TFG-141207 Hinged TFG-141207H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 105 10 51 Maximum fill permitted based solely on minimum wire bending space and 16 17 34 131 electrical clearances 20 7 19 38 25 9 21 41 35 6 16 40 Additional testing required, Consult Factory 50 2 13 38 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 143 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 144 TFG Series - Screw Cover Terminal Enclosure 16''x 14''x 6'' 3B–90 Enclosure Type Catalog Number Chained, Lift-Off TFG-161406 Hinged TFG-161406H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 102 10 49 Maximum fill permitted based solely on minimum wire bending space and 16 17 33 128 electrical clearances 20 7 19 37 25 9 21 40 35 6 15 39 Additional testing required, Consult Factory 50 2 12 32 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 144 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 145 3B–91 TFG Series - Screw Cover Terminal Enclosure 16''x 14''x 7'' Enclosure Type Catalog Number Chained, Lift-Off TFG-161407 Hinged TFG-161407H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 113 10 55 Maximum fill permitted based solely on minimum wire bending space and 16 18 36 142 electrical clearances 20 7 21 41 25 10 23 45 35 6 17 43 Additional testing required, Consult Factory 50 2 14 36 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 145 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 146 TFG Series - Screw Cover Terminal Enclosure 18''x 16''x 8'' 3B–92 Enclosure Type Catalog Number Chained, Lift-Off TFG-181608 Hinged TFG-181608H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 128 10 62 Maximum fill permitted based solely on minimum wire bending space and 16 21 41 161 electrical clearances 20 8 24 46 25 11 26 51 35 7 20 49 Additional testing required, Consult Factory 50 3 16 41 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 146 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 147 3B–93 TFG Series - Screw Cover Terminal Enclosure 18''x 16''x 10'' Enclosure Type Catalog Number Chained, Lift-Off TFG-181610 Hinged TFG-181610H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 142 10 69 Maximum fill permitted based solely on minimum wire bending space and 16 23 46 178 electrical clearances 20 9 26 51 25 12 29 56 35 8 22 55 Additional testing required, Consult Factory 50 3 18 45 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 147 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 148 TFG Series - Screw Cover Terminal Enclosure 20''x 16''x 8'' 3B–94 Enclosure Type Catalog Number Chained, Lift-Off TFG-201608 Hinged TFG-201608H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm2) (amps) 1.5 2.5 4 6 10 16 8 131 10 63 Maximum fill permitted based solely on minimum wire bending space and 16 21 42 164 electrical clearances 20 9 24 47 25 11 27 52 35 8 20 50 Additional testing required, Consult Factory 50 3 16 42 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 148 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 149 3B–95 TFG Series - Screw Cover Terminal Enclosure 20''x 16''x 10'' Enclosure Type Catalog Number Chained, Lift-Off TFG-201610 Hinged TFG-201610H Notes: 1. See the end of this section for applications using multiple terminal block types. 2. For other manufacturers of EEx 'e' type terminal blocks, please consult factory. 3. For Conduit/Cable entry spacings refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. Terminal Block Population for Increased Safety Heat Dissipation Requirements Current Maximum Terminal Block Wire Size (mm5) (amps) 1.5 2.5 4 6 10 16 8 144 10 70 Maximum fill permitted based solely on minimum wire bending space and 16 24 46 181 electrical clearances 20 10 27 52 25 13 29 57 35 8 22 55 Additional testing required, Consult Factory 50 3 18 46 Qualifying Enclosure for Increased Safety Certification 1. Find the Wire Size (conductor) you intend to use to connect to terminal block. 2. Find the Current (amperage) you intend to apply to the conductor. 3. The intersection of the Wire Size (column) and Current (row) gives you the maximum number of terminal blocks permitted for proper heat dissipation and Increased Safety Certification. 4. If the terminal count is too small, decrease the current or increase the wire size until the desired terminal count is found. If neither is possible, continue to the next size enclosure until the desired terminal count is found. 149 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 150 Qualifying Enclosures for Increased Safety Certification with Multiple Terminal Block Types Current (amps) 8 10 16 20 25 35 50 1.5 90 44 15 6 Maximum Terminal Block Wire Size (mm5) 2.5 4 6 10 29 17 8 113 33 18 5 Additional Testing Required, Consult Factory 16 Maximum fill permitted based solely on minimum wire bending space and electrical clearances 36 14 2 35 11 29 Different types of terminals may be used simultaneously by using the tabular values proportionally, as shown below. Example: Current Number 2.5 16 7 (of 29) = 24% 4 20 16 (of 33) = 48% 10 35 9 (of 35) = 26% Total = 98% 3B–96 Conductor Size % of Maximum Terminal Population < 100% Notes: 1. The tables above show the maximum number of single pole (single level) terminal blocks permitted based on the conductor size and the continuous current for the designated enclosures. 2. In the shaded areas you may add as many terminals as possible in accordance with the spacing requirements and manufacturer's instructions. 3. Grounding terminals, bridges and grounding conductors are not counted. 4. Please consult factory for information on multi-pole terminals, grounding terminals, grounding bars, and bridges. 5. When selecting the permitted continuous current for the cross section, the maximum permitted current for the terminals and conductors should be considered. 6. Combinations not covered by the above tables may be permitted if they are determined acceptable by test. 150 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 B 12/9/01 10:47 AM Page 151 Conduit/Cable & Wire Bending Guidelines Table A - Minimum Spacing Between Centers of Conduit or Cable Entries NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 NPT METRIC -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 1/16 ~ 3/8 -- 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 1-1/8 [29mm] 1/2 M16 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 3/4 M20 4-1/2 [115mm] 3-3/4 [96mm] 3-1/2 3-1/8 [89mm] [80mm] 2-3/4 [70mm] 2-1/2 [64mm] 2-1/8 [54mm] 2 [51mm] 1-3/4 [45mm] 1-1/2 [38mm] 1 M25 4-5/8 [118mm] 3-7/8 [99mm] 3-5/8 3-1/4 [92mm] [83mm] 2-7/8 [74mm] 2-3/4 [70mm] 2-1/4 [58mm] 2-1/8 [54mm] 1-7/8 [48mm] 1-1/4 M32 4-7/8 [124mm] 4-1/8 [105mm] 3-7/8 [99mm 3-1/2 [89mm] 3-1/8 [80mm] 2-7/8 [74mm] 2-1/2 [64mm] 2-3/8 [61mm] 1-1/2 M40 5 [127mm] 4-1/4 4 3-5/8 [108mm] [102mm] [92mm] 3-1/4 [83mm] 3 [77mm] 2-5/8 [68mm] 2 M50 5-3/8 [137mm] 4-3/4 4-1/2 4 3-5/8 [121mm] [115mm] [102mm] [92mm] 3-3/8 [86mm] 2-1/2 M63 5-1/2 [140mm] 4-7/8 4-5/8 4-1/4 3-7/8 [124mm] [118mm] [108mm] [99mm] 3 M75 5-7/8 [150mm] 5-1/4 5 4-5/8 [134mm] [127mm] [118mm] 3-1/2 -- 6-1/4 [159mm] 5-3/4 5-1/2 [147mm] [140mm] 4 -- 6-7/8 [175mm] 6 [153mm] 5 -- 7-3/8 [188mm] 3B–97 SIZE This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and condition under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 2-13/16 [72mm] 2-1/4 [58mm] 2 [51mm] 1-3/16 [31mm] 1 [26mm] 7/8 [23mm] 11/16 [18mm] 9/16 [14mm] 1/2 [13mm] 1/2 [13mm] METRIC 1-3/4 1-7/16 [45mm] [37mm] Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls AWG 16 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0 250 350 400 500 mm sq. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1-1/2 1-1/2 1-1/2 1-1/2 2 3 3-1/2 5-1/2 6 6-1/2 7 8-1/2 10 12 13 14 [38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm] Notes: 1. The distances in Table A are recommended minimum distances between centers of conduit and cable gland entries. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 2. The distances in Table B are recommended minimum distances between center of conduit and cable gland entries to the edge of an opening or inside wall of box. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 3. The distances in Table C are the minimum wire bending space requirements between terminals, partitions, or inside walls. 151 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 C 12/9/01 10:52 AM Page 152 HV Series - High Voltage Junction Boxes Options Gland Plates: These removable plates offer great flexibility for the end user to drill holes without having to remove the entire enclosure from the installation site. Add the following Suffixes: -A: Gland Plate installed on top of box. -B: Gland Plate installed on bottom of box. -C: Gland Plate installed on left of box. -D: Gland Plate installed on right of box. For multiple gland plates omit dashes (i.e. HV4X-201407-ABCD) Conduit/Cable Entries: 3C–1 Entries can be provided per a customer sketch or with detailed information on the entry locations. Please refer to Entry Spacing Tables at the end of this section. Note: This information is important and could affect the size of the enclosure you selected. Close-up Plugs: Construction Any unused entries must be plugged with a Certified Close-Up Plug. Adalet can provide close-up plugs in various styles and materials. Please indicate on the sketch or provide detailed information of holes to be plugged. • Available in (3) Materials: SS304, SS316L, Powder Coated (ASA61 Grey) Steel Enclosure Labeling: • Folded Lip around the Door Opening to provide complete and maximum gasket seal Adalet can provide additional enclosure labeling with custom silk screening or various colors of Lamacoid™ nameplates. Please provide detailed information of the logo or text required. • Continuously Welded and Ground Smooth Seams • Silicone Strip Gasket • Welded on External Mounting Feet with 5/16” Clearance Holes/Slot Breather Drains: • External Door Clamps • Continuous Piano Type Hinge with Removable SS Hinge Pin • Ground Studs on Box and Cover Breather Drains can be provided per customer request. They are available in Brass or Stainless Steel 316L. Please indicate on a sketch or provided detailed information for locations. • Internal/External Earthing Lugs • Universal Rail Mounting System Mounting Pans: • Padlock Hasp & Staple for Padlocking As an alternative to the universal rail mounting system, mounting pans are available in steel/powder coated, stainless steel, and aluminum. Please indicate when requesting quote. 152 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 C 12/9/01 10:52 AM Page 153 HV Series - High Voltage Junction Boxes General Information Adalet's Single Door Clamped High Voltage Junction Boxes are available in Stainless Steel 316L & 304 and Carbon Steel. Silicone gaskets, removable hinge pin, box & cover ground studs including an internal/external earthing stud, and a universal rail mounting system are included as standard. Working Voltage Material 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) Ex e II T6 (T5 Tamb +55°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) Class II, Division 2 IP66 Type 4, 4X (Stainless Steel only), 12, & 13 AC HV4 Series HV4X Series HV4X6 Series HV4 Series Gland Plates HV4X Series Gland Plates HV4X6 Series Gland Plates Universal Rail System Mounting Pan Gasket Lid Fixing Hinge Door Clamps Enclosure Mounting Gland Plate Hardware Grounding Impact Resistant Ambient Temperature Range Box & Cover Earthing Lugs HV4 Series HV4X Series HV4X6 Series HV4 Series HV4X Series HV4X6 Series All Types All Types All Types All Types All Types All Types 3C–2 Enclosure Certifications ATEX Directive 94/9/EC EN50014/EN50019 CSA E79-7, IEC 60079-7 UL 2279-7 UL 1604 IEC 60529 UL50 8kV Maximum #14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray #14ga Stainless Steel 304, Brushed Finish #14ga Stainless Steel 316, Brushed Finish #10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray #10ga Stainless Steel 304, Brushed Finish #10ga Stainless Steel 316, Brushed Finish 300 Series Stainless Steel #14ga Cold Rolled Steel, Polyester Powder Coated White Silicone Sponge Continuous piano type - Steel with removable SS304 pin Continuous piano type - SS304 with removable pin Continuous piano type - SS316 with removable pin Plated Steel Clear Stainless Steel 304 Stainless Steel 316 Four (4) external lugs with .44" clearance holes/slots 300 Series stainless steel 1/4-20 Stud with 300 series stainless steel hardware #6-350MCM - Al/Cu 7 Nm to EN50014/EN50019 -40°C to +55°C to EN50014 D 153 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 C 12/9/01 10:52 AM Page 154 HV Series - High Voltage Junction Boxes 1 x 1 Connection Series Shielded or Unshielded Cables 3C–3 SS316L CATALOG NUMBERS H W D M N Maximum Voltage Maximum Amps (T5/T6) # of Clamps HV4X6-241206 610 305 152 664 241 1.5kV 315 5 HV4X6-242006 610 508 152 664 356 1.5kV 315 5 HV4X6-201206 508 305 152 562 241 2.5kV 250 4 HV4X6-161606 406 406 152 460 254 2.5kV 200 4 HV4X6-241606 610 406 152 664 254 2.5kV 315 5 HV4X6-301606 762 406 152 816 254 2.5kV 400 5 HV4X6-202006 508 508 152 562 356 2.5kV 250 4 HV4X6-201407 508 356 178 562 203 2.5kV 250 4 HV4X6-251807 635 457 178 689 305 2.5kV 315 5 HV4X6-302207 762 559 178 816 406 2.5kV 400 5 HV4X6-362507 914 635 178 968 483 2.5kV 400 8 HV4X6-201610 508 406 254 562 254 6.6kV 250 4 HV4X6-302010 762 508 254 816 356 8kV 400 5 HV4X6-242010 610 508 254 664 356 8kV 315 5 HV4X6-302410 762 762 254 816 458 8kV 400 5 HV4X6-242410 610 610 254 664 458 8kV 315 5 HV4X6-362410 914 610 254 968 458 8kV 400 5 HV4X6-362510 914 635 254 968 483 8kV 500 8 HV4X6-603610 1524 914 254 1578 762 8kV 500 9 HV4X6-603616 1524 914 406 1578 762 8kV 500 9 Notes: 1. For stainless steel 304 assemblies substitute HV4X6- prefix with HV4X- prefix. 2. For steel powder coated assemblies substitute HV4X6- prefix with HV4- prefix. 3. Please specify working voltage and amperage when requesting quote. 4. For conduit/cable entry spacing and minimum wire bending space requirements, refer to the end of this section. 154 ADALET Enclosure Systems • Designing Our Products Around Yours SM The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 C 12/9/01 10:52 AM Page 155 HV Series - High Voltage Junction Boxes 2 x 2 Connection Series SS316L CATALOG NUMBERS H W D M N Maximum Voltage Maximum Amps (T6) Maximum Amps (T5) # of Clamps HV4X6-202008 508 508 203 562 356 1.1kV 500 500 4 HV4X6-242008 610 508 203 664 356 1.1kV 630 630 5 HV4X6-242408 610 610 203 664 458 1.1kV 630 630 5 HV4X6-202010 508 508 254 562 356 1.1kV 500 500 4 HV4X6-242010 610 508 254 664 356 1.1kV 630 630 5 HV4X6-302010 762 508 254 816 356 1.1kV 650 800 5 HV4X6-242410 610 610 254 664 458 1.1kV 630 630 5 HV4X6-302410 762 610 254 816 458 1.1kV 650 800 5 HV4X6-362410 914 610 254 968 458 1.1kV 650 800 5 HV4X6-362510 914 635 254 968 483 1.1kV 650 1000 8 HV4X6-603610 1524 914 254 1578 762 1.1kV 650 1000 9 3C–4 2 Parallel Unshielded Cables Notes: 1. For stainless steel 304 assemblies substitute HV4X6- prefix with HV4X- prefix. 2. For steel powder coated assemblies substitute HV4X6- prefix with HV4- prefix. 3. Please specify working voltage and amperage when requesting quote. 4. For conduit/cable entry spacing and minimum wire bending space requirements, refer to the end of this section. The Adalet Engineering Department is available to assist you in the selection of Increased Safety Enclosures. 155 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 C 12/9/01 10:52 AM Page 156 Conduit/Cable & Wire Bending Guidelines Table A - Minimum Spacing Between Centers of Conduit or Cable Entries 3C–5 SIZE NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 NPT METRIC -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 1/16 ~ 3/8 -- 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 1-1/8 [29mm] 1/2 M16 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 3/4 M20 4-1/2 [115mm] 3-3/4 [96mm] 3-1/2 3-1/8 [89mm] [80mm] 2-3/4 [70mm] 2-1/2 [64mm] 2-1/8 [54mm] 2 [51mm] 1-3/4 [45mm] 1-1/2 [38mm] 1 M25 4-5/8 [118mm] 3-7/8 [99mm] 3-5/8 3-1/4 [92mm] [83mm] 2-7/8 [74mm] 2-3/4 [70mm] 2-1/4 [58mm] 2-1/8 [54mm] 1-7/8 [48mm] 1-1/4 M32 4-7/8 [124mm] 4-1/8 [105mm] 3-7/8 [99mm 3-1/2 [89mm] 3-1/8 [80mm] 2-7/8 [74mm] 2-1/2 [64mm] 2-3/8 [61mm] 1-1/2 M40 5 [127mm] 4-1/4 4 3-5/8 [108mm] [102mm] [92mm] 3-1/4 [83mm] 3 [77mm] 2-5/8 [68mm] 2 M50 5-3/8 [137mm] 4-3/4 4-1/2 4 3-5/8 [121mm] [115mm] [102mm] [92mm] 3-3/8 [86mm] 2-1/2 M63 5-1/2 [140mm] 4-7/8 4-5/8 4-1/4 3-7/8 [124mm] [118mm] [108mm] [99mm] 3 M75 5-7/8 [150mm] 5-1/4 5 4-5/8 [134mm] [127mm] [118mm] 3-1/2 -- 6-1/4 [159mm] 5-3/4 5-1/2 [147mm] [140mm] 4 -- 6-7/8 [175mm] 6 [153mm] 5 -- 7-3/8 [188mm] This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and condition under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 2-13/16 [72mm] 2-1/4 [58mm] 2 [51mm] 1-3/16 [31mm] 1 [26mm] 7/8 [23mm] 11/16 [18mm] 9/16 [14mm] 1/2 [13mm] 1/2 [13mm] METRIC 1-3/4 1-7/16 [45mm] [37mm] Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls AWG 16 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0 250 350 400 500 mm sq. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1-1/2 1-1/2 1-1/2 1-1/2 2 3 3-1/2 5-1/2 6 6-1/2 7 8-1/2 10 12 13 14 [38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm] Notes: 1. The distances in Table A are recommended minimum distances between centers of conduit and cable gland entries. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 2. The distances in Table B are recommended minimum distances between center of conduit and cable gland entries to the edge of an opening or inside wall of box. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 3. The distances in Table C are the minimum wire bending space requirements between terminals, partitions, or inside walls. 156 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 157 CN Series Auxiliary Devices: 85 Enclosure Sizes Available in eighty-five (85) sizes, ranging from 16”x12”x6” (model 161206) to 60”x36”x12” (model 603612). Pushbuttons - Rated 250V, 16A (T6) - 11A (T5) 3D–1 • Single Button • Dual Construction • Mushroom Head & Keyed Mushroom Head • Available in (3) Materials: SS304, SS316L, Powder Coated (ASA61 Grey) Steel Selector Switches - Rated 250V, 16A (T6) - 11A (T5) • Folded Lip around the Door Opening to provide complete and maximum gasket seal • Two or Three Position • Continuously Welded and Ground Smooth Seams • Keyed • Silicone Strip Gasket • Momentary or Maintained • Welded on External Mounting Feet with 5/16” Clearance Holes/Slot • External Door Clamps Pilot Lights - Rated 12-240VAC, 12-110VDC, W 1W • Continuous Piano Type Hinge with Removable SS Hinge Pin • Lens Colors: Blue, Green, Red, Yellow, White • Ground Studs on Box and Cover • Internal/External Earthing Stud Potentiometers - Rated 250V • Padlock Hasp & Staple for Padlocking • 1W @ 1K, 4700, or 10K Ohms Options Measuring Instruments: Gland Plates: Ammeters, Voltmeters - Rated 420V or 750V These removable plates offer great flexibility for the end user to drill holes without having to remove the entire enclosure from the installation site. • Direct Measurement Add the following Suffixes: • Interchangeable Scales • Indirect Measurement -A: Gland Plate installed on top of box. -B: Gland Plate installed on bottom of box. -C: Gland Plate installed on left of box. -D: Gland Plate installed on right of box. For multiple gland plates omit dashes (i.e. CN4X-201407-ABCD) 157 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 158 CN Series General Information Adalet's Single Door Clamped Control Enclosures are available in Stainless Steel 316L & 304 and Carbon Steel. Adalet can also supply custom size enclosures, operators, and wiring of devices to rail mounted terminal blocks to suit your Increased Safety Application. Silicone gaskets, removable hinge pin, box & cover ground studs including an internal/external earthing stud, along with internal standoffs for mounting pans are included as standard. 3D–2 Enclosure Certifications 0539 II 2GD EEx e II T6 Tamb +40°C (T5 Tamb +55°C) IP66 Working Voltage Terminal Blocks Material Gasket Lid Fixing Various Manufacturers CN4 Series CN4X Series CN4X6 Series CN4 Series Gland Plates CN4X Series Gland Plates CN4X6 Series Gland Plates Mounting Pan Hinge Door Clamps Enclosure Mounting Gland Plate Hardware Grounding Impact Resistant Ambient Temperature Range Box & Cover Earthing Stud CN4 Series CN4X Series CN4X6 Series CN4 Series CN4X Series CN4X6 Series All Types All Types All Types All Types All Types All Types ATEX Directive 94/9/EC EN50014/EN50019 IEC 60529 Up to 1100 Volts Maximum EEx e type with wire sizes 1.5mm up to 240mm #14ga Cold Rolled Steel, Polyster Powder Coated ANSI 61 Gray #14ga Stainless Steel 304, Brushed Finish #14ga Stainless Steel 316, Brushed Finish #10ga Cold Rolled Steel, Polyester Powder Coated ANSI 61 Gray #10ga Stainless Steel 304, Brushed Finish #10ga Stainless Steel 316, Brushed Finish #14ga Cold Rolled Steel, Polyester Powder Coated White Silicone Sponge Continuous piano type - Steel with removable SS304 pin Continuous piano type - SS304 with removable pin Continuous piano type - SS316 with removable pin Plated Steel Clear Stainless Steel 304 Stainless Steel 316 Four (4) external lugs with .44" clearance holes/slots 300 Series stainless steel 1/4-20 Stud with 300 series stainless steel hardware 1/4-20 Stud - All components brass 7 Nm to EN50014/EN50019 -20°C to +55°C to EN50014 D 158 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 159 CN Series – Catalog Numbers & Enclosure Sizes ENCLOSURE SIZE -1224xx -1612xx -1616xx -1620xx -2012xx -2016xx -2020xx -2024xx -2412xx -2416xx -2420xx -2424xx -301606 -3020xx -3024xx -3624xx -3630xx -2430xx -3030xx -303608 -3636xx -422408 -4230xx -4236xx -482408 -4830xx -4836xx -6036xx H 305 406 406 406 508 508 508 508 610 610 610 610 762 762 762 914 914 610 762 762 914 1067 1067 1067 1219 1219 1219 1524 W 610 305 406 508 305 406 508 610 305 406 508 610 406 508 610 610 762 762 762 914 914 610 762 914 610 762 914 914 06 152 152 152 152 152 152 152 152 152 152 152 152 152 152 152 152 152 ------------ 08 203 203 203 203 203 203 203 203 203 203 203 203 -203 203 203 203 203 203 203 203 203 203 203 203 203 203 203 10 -254 ---254 254 -254 -254 254 -254 254 254 254 -----254 254 -254 254 254 D 12 -----305 ----305 305 --305 305 305 -305 -305 -305 305 --305 305 16 ----------406 406 --406 -406 ------406 --406 406 20 --------------508 -508 ---------508 508 24 --------------588 ------------588 M N S T 359 460 460 460 562 562 562 562 664 664 664 664 816 816 816 968 968 664 816 816 968 1121 1121 1121 1273 1273 1273 1578 458 241 254 356 241 254 356 458 241 254 356 458 254 356 458 458 610 610 610 762 762 458 610 762 458 610 762 762 229 330 330 330 432 432 432 432 534 534 534 534 686 686 686 838 838 534 686 686 838 991 991 991 1143 1143 1143 1448 534 229 330 432 229 330 432 534 229 330 432 534 330 432 534 534 686 686 686 838 838 534 686 838 534 686 838 838 # OF CLAMPS 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 7 7 7 7 7 6 8 8 6 8 8 9 3D–3 DIMENSIONS IN TABLE ARE METRIC STIFFENER BOX COVER ----------------------------------------------------------------REQ'D REQ'D ----REQ'D REQ'D REQ'D REQ'D REQ'D REQ'D --REQ'D REQ'D REQ'D REQ'D REQ'D --REQ'D REQ'D REQ'D REQ'D REQ'D REQ'D REQ'D To build catalog number: 1. For enclosure sizes ending in xx, select enclosure depth for your application from column D. (i.e. -243008) 3. For Stainless Steel 304 enclosures add prefix CN4X. (i.e. CN4X-243008) 2. For Stainless Steel 316L enclosures add prefix CN4X6. (i.e. CN4X6-243008) 4. For Steel Powder Coated enclosures add prefix CN4. (i.e. CN4-243008) ADALET Enclosure Systems • Designing Our Products Around Yours SM 159 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 160 CN Series – Auxiliary Devices Pilot Lights II 2 G EEx de IIC IEC 60529: IP66 Rated Operating Voltage: AC 24V, 48V, 110V, 230V; DC 24V, 48V Lamp: Multi-LED Electrical Life: 105 Hours Illuminated Catalog Numbers Red: 07-3353-1110/1000 Green: 07-3353-1120/2000 Yellow: 07-3353-1130/3000 White: 07-3353-1140/4000 Blue: 07-3353-1150/5000 Pushbuttons 3D–4 II 2 G EEx de IIC IEC60529: IP66 Rated Insulation Voltage: 300V Nominal Currents: 16A/+40°C, 11A/ +60°C Catalog Numbers Pushbuttons Pushbutton, 1NO/1NC: 07-3323-1400/1000 Pushbutton, 2NO: 07-3323-1200/1000 Pushbutton, 2NC: 07-3323-1100/1000 * Pushbuttons are supplied with (4) loose colored discs: Red, Green, Yellow, White Mushroom Head Pushbuttons Mushroom, Black, 1NO/1NC: Mushroom, Black, 2NO: Mushroom, Black, 2NC: Mushroom, Black, Lockable, 1NO/1NC: Mushroom, Black, Lockable, 2NO: Mushroom, Black, Lockable, 2NC: 07-3323-1400/5000 07-3323-1200/5000 07-3323-1100/5000 07-3323-1400/6300 07-3323-1200/6300 07-3323-1100/6300 Emergency Stop Pushbuttons II 2 G EEx de IIC IEC 60529: IP66 Rated Insulation Voltage: 300V Nominal Currents: 16A/+40°C, 11A/ +60°C Catalog Numbers 1NO/1NC: 07-3323-1400/2000 2NO: 07-3323-1200/2000 2NC: 07-3323-1100/2000 160 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 161 CN Series – Auxiliary Devices Selector Switches II 2 G EEx de IIC IEC 60529: IP66 Rated Insulation Voltage: 300V Nominal Currents: 16A/+40°C, 11A/ +60°C Catalog Numbers Maintained Selector Switches 2-Position, 1NO/1NC: 07-3323-1400/3000 2-Position, 2NO: 07-3323-1200/3000 2-Position, 2NC: 07-3323-1100/3000 3-Position, 1NO/1NC: 07-3323-1400/4000 3-Position, 2NO: 07-3323-1200/4000 3-Position, 2NC: 07-3323-1100/4000 3D–5 Momentary (Left-Right) Selector Switches 3-Position, 1NO/1NC: 07-3323-1400/4100 3-Position, 2NO: 07-3323-1200/4100 3-Position, 2NC: 07-3323-1100/4100 Latching (Left) - Momentary (Right) Selector Switches 3-Position, 1NO/1NC: 07-3323-1400/4200 3-Position, 2NO: 07-3323-1200/4200 3-Position, 2NC: 07-3323-1100/4200 Momentary (Left) - Latching (Right) Selector Switches 3-Position, 1NO/1NC: 07-3323-1400/4300 3-Position, 2NO: 07-3323-1200/4300 3-Position, 2NC: 07-3323-1100/4300 Keyed Selector Switches (2 Position) Lockable Both Positions, Key Removable Both Positions, 1NO/1NC: 07-3323-1400/6000 Lockable Both Positions, Key Removable Both Positions, 2NO: 07-3323-1200/6000 Lockable Both Positions, Key Removable Both Positions, 2NC: 07-3323-1100/6000 Lockable Depressed Position, Key Removable Depressed Position, 1NO/1NC: 07-3323-1400/6100 Lockable Depressed Position, Key Removable Depressed Position, 2NO: 07-3323-1200/6100 Lockable Depressed Position, Key Removable Depressed Position, 2NC: 07-3323-1100/6100 Lockable Initial Position, Key Removable Initial Position, 1NO/1NC: 07-3323-1400/6200 Lockable Initial Position, Key Removable Initial Position, 2NO: 07-3323-1200/6200 Lockable Initial Position, Key Removable Initial Position, 2NC: 07-3323-1100/6200 161 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 162 CN Series – Auxiliary Devices Potentiometers EEx de IIC IEC 60529: IP66 Rated Voltage/Power: 250V / 1 Watt 1 Turn Scale: 0 - 100% Catalog Numbers 1 Watt, 1000 Ohm: GHG 418 8131 R0014 1 Watt, 4700 Ohm: GHG 418 8131 R0015 1 Watt, 10000 Ohm: GHG 418 8131 R0016 Measuring Instruments 3D–6 EEx e IIC IEC 60529: IP66 Current Type: AC or DC Movement: Moving Iron Exactitude of Measurment: Class 2.5 Rated Current: Red Indicator Zero Adjustment: Adjustment Screw on Instrument Overload Range: 1 : 1.5 (indicated) CATALOG NUMBERS Movement n / 1A 0 - 20 mA (Ri = 320 Ohm) 4 - 20 mA (Ri = 320 Ohm) Other Code for Movement: 1 = Direct Measurment Code for Interchangeable Scales: Direct Measurement: Scale Code 02 0 - 1 / 1.5 A 03 0 - 2.5 / 3.75 A 04 0 - 5 / 7.5 A 05 0 - 10 / 15 A 07 0 - 16 / 24 A 08 0 - 20 / 30 A Scale 0 - 100 / 150 % 0 - 100 / 120 % 0 - 100 / 120 % Catalog Number GHG 412 8282 R0031 GHG 412 8285 R0033 GHG 412 8286 R0035 -- GHG 412 828___ R00___ 2 = Instrument Transformer Connection, n / 1A Interchangeable Scale: Code Scale 02 0 - 1 / 1.5 A 03 0 - 2.5 / 3.75 A 04 0 - 5 / 7.5 A 05 0 - 10 / 15 A 07 0 - 16 / 24 A 08 0 - 20 / 30 A Code 09 10 11 12 13 14 15 Scale 0 - 30 / 45 A 0 - 40 / 60 A 0 - 50 / 75 A 0 - 60 / 90 A 0 - 75 / 112.5 A 0 - 100 / 150 A 0 - 150 / 225 A Code 16 17 18 19 20 21 Scale 0 - 200 / 300 A 0 - 250 / 375 A 0 - 300 / 450 A 0 - 400 / 600 A 0 - 500 / 750 A 0 - 600 / 900 A 162 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 163 "B" (BOX OPENING) 30mm MINIMUM FROM BOX OPENING OR STIFFENER 60mm MINIMUM BETWEEN VERTICAL ROWS 110mm BETWEEN VERTICAL ROWS 79mm BETWEEN METER AND OPERATOR HOLE 60mm WIDE DOOR STIFFENER (SEE TABLE IF REQ'D) 60mm MINIMUM FROM BOX OPENING OR STIFFENER DIMENSIONS IN TABLE ARE METRIC Cover Size -1224 -1612 -1616 -1620 -2012 -2016 -2020 -2024 -2412 -2416 -2420 -2424 -2430 -3016 -3020 -3024 -3030 -3036 -3624 -3630 -3636 -4224 -4230 -4236 -4824 -4830 -4836 -6036 Box Opening A B 229 533 330 229 330 330 330 432 432 229 432 330 432 432 432 533 533 229 533 330 533 432 533 533 533 686 686 330 686 432 686 533 686 686 686 838 838 533 838 686 838 838 991 533 991 686 991 838 1143 533 1143 686 1143 838 1448 838 Door Stiffener ---------------------YES YES YES YES YES YES YES Max No. Of Operator Rows Horiz Vert 2 8 4 3 4 5 4 7 5 3 5 5 5 7 5 8 7 3 7 5 7 7 7 8 7 11 9 5 9 7 9 8 9 11 9 13 11 8 11 11 11 13 13 6 13 10 13 12 15 6 15 10 15 12 20 12 Max No. Of Operators 16 12 20 28 18 25 35 40 21 35 49 56 77 45 63 72 99 117 88 121 143 78 130 156 90 150 180 240 Max No. Of GHG Type Meter Rows Horiz Vert 1 4 1 1 1 2 1 3 2 1 2 2 2 3 2 4 2 1 2 2 2 3 2 4 2 6 3 2 3 3 3 4 3 6 3 7 3 4 3 6 3 7 4 4 4 4 4 6 5 4 5 4 5 6 6 6 3D–7 106mm MINIMUM DISTANCE FROM BOTTOM OF METER 133mm MINIMUM DISTANCE FROM BOTTOM OF METER TO OPERATOR 227mm BETWEEN METERS 148mm x 86mm CUTOUT 120mm MINIMUM DISTANCE FROM TOP OF METER TO OPERATOR 70mm MINIMUM BETWEEN HORIZONTAL ROWS 47mm MINIMUM FROM BOX OPENING ÿ30.5mm OPERATOR HOLE (SEE TABLE FOR MAXIMUM QTY.) "A" (BOX OPENING) 93mm MINIMUM DISTANCE FROM TOP OF METER CN Series – Cover Matrix Max No. Of GHG Type Meters 4 1 2 3 2 4 6 8 2 4 6 8 12 6 9 12 18 21 12 18 21 16 16 24 20 20 30 36 163 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 164 Conduit/Cable & Wire Bending Guidelines Table A - Minimum Spacing Between Centers of Conduit or Cable Entries 3D–8 SIZE NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 NPT METRIC -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 1/16 ~ 3/8 -- 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 1-1/8 [29mm] 1/2 M16 4-3/8 [112mm] 3-5/8 [92mm] 3-3/8 3 [86mm] [77mm] 2-5/8 [68mm] 2-3/8 [61mm] 2 [51mm] 1-7/8 [48mm] 1-5/8 [42mm] 1-3/8 [35mm] 1-1/4 [32mm] 3/4 M20 4-1/2 [115mm] 3-3/4 [96mm] 3-1/2 3-1/8 [89mm] [80mm] 2-3/4 [70mm] 2-1/2 [64mm] 2-1/8 [54mm] 2 [51mm] 1-3/4 [45mm] 1-1/2 [38mm] 1 M25 4-5/8 [118mm] 3-7/8 [99mm] 3-5/8 3-1/4 [92mm] [83mm] 2-7/8 [74mm] 2-3/4 [70mm] 2-1/4 [58mm] 2-1/8 [54mm] 1-7/8 [48mm] 1-1/4 M32 4-7/8 [124mm] 4-1/8 [105mm] 3-7/8 [99mm 3-1/2 [89mm] 3-1/8 [80mm] 2-7/8 [74mm] 2-1/2 [64mm] 2-3/8 [61mm] 1-1/2 M40 5 [127mm] 4-1/4 4 3-5/8 [108mm] [102mm] [92mm] 3-1/4 [83mm] 3 [77mm] 2-5/8 [68mm] 2 M50 5-3/8 [137mm] 4-3/4 4-1/2 4 3-5/8 [121mm] [115mm] [102mm] [92mm] 3-3/8 [86mm] 2-1/2 M63 5-1/2 [140mm] 4-7/8 4-5/8 4-1/4 3-7/8 [124mm] [118mm] [108mm] [99mm] 3 M75 5-7/8 [150mm] 5-1/4 5 4-5/8 [134mm] [127mm] [118mm] 3-1/2 -- 6-1/4 [159mm] 5-3/4 5-1/2 [147mm] [140mm] 4 -- 6-7/8 [175mm] 6 [153mm] 5 -- 7-3/8 [188mm] This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and condition under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Table B - Minimum Distance from Conduit/Cable Center to Edge of Opening or Edge of Box NPT 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 1/16 ~ 3/8 -- -- -- M75 M63 M50 M40 M32 M25 M20 M16 -- 2-13/16 [72mm] 2-1/4 [58mm] 2 [51mm] 1-3/16 [31mm] 1 [26mm] 7/8 [23mm] 11/16 [18mm] 9/16 [14mm] 1/2 [13mm] 1/2 [13mm] METRIC 1-3/4 1-7/16 [45mm] [37mm] Table C - Minimum Wire Bending Space Between Terminals, Partitions, or Inside Walls AWG 16 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0 250 350 400 500 mm sq. 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1-1/2 1-1/2 1-1/2 1-1/2 2 3 3-1/2 5-1/2 6 6-1/2 7 8-1/2 10 12 13 14 [38mm] [38mm] [38mm] [38mm] [51mm] [77mm] [89mm] [140mm] [153mm] [165mm] [178mm] [216mm] [254mm] [305mm] [330mm] [356mm] Notes: 1. The distances in Table A are recommended minimum distances between centers of conduit and cable gland entries. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 2. The distances in Table B are recommended minimum distances between center of conduit and cable gland entries to the edge of an opening or inside wall of box. Consult manufacturer of conduit fitting or cable glands for their recommended minimum spacing. 3. The distances in Table C are the minimum wire bending space requirements between terminals, partitions, or inside walls. 164 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 D 12/9/01 10:54 AM Page 165 CN Series – Enclosure Specification Sheet Name: Company: Street/PO Box: Phone: City/State/Country/Zip: Fax: Enclosure Catalog Number: Gland Plate(s): Mounting Pan: Breather/Drain: ❑ Top (-A) ❑ Steel, Powder Coated ❑ Breather Nominal Working Voltage: AC ❑ Bottom (-B) ❑ Stainless Steel ❑ Drain V ❑ Left (-C) ❑ Aluminum ❑ Brass DC Auxiliary Devices ❑ Right (-D) ❑ Stainless Steel V Qty. Tag 1: 2: 3D–9 3: 4: 5: 6: 7: 8: 9: 10: Use Second Sheet For Additional Devices 2.5mm Terminal Blocks Qty. Conduit/Cable Entries: Top Side Qty. Tag Bottom Side Qty. Left Side Qty. Right Side Qty. 1: 2: 3: 4: 5: Use Second Sheet For Additional Devices Enclosure Labeling: 165 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 E 12/9/01 10:56 AM Page 166 Intrinsically Safe Terminal Enclosures Areas of Use Zone Classified Areas - U.S., Canada, Europe Intrinsically Safe 'ia': Zones 0, 1 and 2 Intrinsically Safe 'ib': Zones 1 and 2 Division Classified Areas - U.S. Intrinsically Safe (2 fault): Class I, II, and III, Division 1 ATEX - EU Directive 94/9/EC Equipment Groups I and II Intrinsically Safe 'ia': Category 1GD or M1 Intrinsically Safe 'ib': Category 2GD or M2 Applicable Standards 3E–1 General Information Europe: EN50014, EN50020 Adalet’s Intrinsically Safe Terminal Enclosures are available in (33) standard enclosure sizes of Stainless Steel 316L, Stainless Steel 304, Steel Powder Coated and Fiberglass Reinforced Polyester materials. Adalet can also supply custom size enclosures and terminal rail configurations to meet your Intrinsically Safe applications. These enclosures are suitable for areas where ignitable concentration of flammable gases, vapors, liquids, and dusts can exists under normal operating conditions. They are also ideal for indoor and outdoor areas where dampness and highly corrosive atmospheres are present such as refineries, water treatment, food processing, coating, salt, and chemical facilities. U.S.: UL2279 pt 11, ANSI/UL 913 Basic Principle of Intrinsically Safe Intrinsic safety is intended for product in which the level of electrical energy circulating or stored in the product is insufficient to ignite a surrounding explosive atmosphere even under fault conditions. Note: No one device or wiring is intrinsically safe by itself (except self-contained devices i.e. pagers, portable gas detectors, etc.) but is intrinsically safe when incorporated into a properly designed intrinsically safe system. Canada: CSA-E79-0, CSA-E79-11 International: IEC60 079-0, IEC60 079-11 Key Design Features Intrinsically Safe equipment must not be capable of causing ignition of a surrounding explosive atmosphere under specified conditions including: two countable faults: Category 'ia' one countable fault: Category 'ib' Enclosures must provide at least IP20 protection in accordance with EN60529, with higher levels of protection required for certain applications. (i.e. an enclosure containing intrinsically safe terminals and increased safety terminals would require an increased safety enclosure 'e' and minimum IP54 rating.) Temperatures of wiring and small components must be limited to the specified values according to the T-Class of the equipment. Separation of conductive parts must be achieved in terms of specified clearances and creepage distances. Particular attention is required for separation of intrinsically safe circuits from non-intrinsicaly safe circuits. Components on which intrinsic safety depends must be of specified rating and construction. Blue is the internationally recognized color for intrinsically safe wiring and terminal blocks. The Adalet Engineering Department is available to assist in your Intrinsically Safe Terminal Enclosure Selection 166 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 E 12/9/01 10:56 AM Page 167 Intrinsically Safe Terminal Enclosures - TSC & TFG Series Options Gland Plates (TSC Series Only): Conduit/Cable Entries: For enclosures with depths greater than 6” Entries can be provided per a customer sketch or with detailed information on the entry locations. Please refer to Entry Spacing Tables at the end of the Increased Safety Section in the CENELEC Product Catalog. Note: This information is important and could affect the size of the enclosure you selected. These removable plates offer great flexibility for the end user to drill holes without having to remove the entire enclosure from the installation site. Add the following Suffixes: -A: Gland Plate installed on top of box. -B: Gland Plate installed on bottom of box. -C: Gland Plate installed on left of box. -D: Gland Plate installed on right of box. For multiple gland plates omit dashes (i.e. TSC4X-101006-ABCD) Close-up Plugs: Any unused entries must be plugged with a Certified CloseUp Plug. Adalet can provide close-up plugs in various styles and materials. Please indicate on the sketch or provide detailed information of holes to be plugged. EMC Shielding (TSC Series Only): Enclosure Labeling: EMC shielding is available on the TSC4X (SS304) and TSC4X6 (SS316L) enclosures with a shielding effectiveness of >50dB through out the frequency range of 1MHz to 100MHz. For EMC shielding add the prefix -EMC to the catalog text string, immediately following the enclosure size. (i.e. TSC4X-101006-EMC) Note: This option is not available on enclosures with gland plates installed. Adalet can provide additional enclosure labeling with custom silk screening or various colors of Lamacoid™ nameplates. Please provide detailed information of the logo or text required. 3E–2 For stainless steel enclosures only Breather Drains: Breather Drains can be provided per customer request. They are available in Brass or Stainless Steel 316L. Please indicate on a sketch or provide detailed information for locations. Hinged Cover (TFG Series Only): A stainless steel piano type hinge is available by adding an H to the end of the catalog string. (i.e. TFG-201407H) Grounding Busbars: Earthing Stud Assembly (TFG Series Only): Some applications might require grounding points to be terminated in the enclosure. With the use of a Ground Busbar System this can be accomplished, consult factory for options. An Internal/External Earthing Stud can be provided upon request. Please specify on the request for quote. Mounting Pans: As an alternative to the universal rail mounting system, mounting pans are available in steel/powder coated, stainless steel, and aluminum. Please indicate when requesting quote. Terminal Strip Assemblies: Various options (i.e. marking tags, protective covers, jumpers, partitions...) are available. Please provide detailed information requesting quote. 167 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 E 12/9/01 10:56 AM Page 168 TSC Series - Intrinsically Safe Circuits Certifications 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Ex e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class II, Division 2 IEC60529: IP66 UL50: Type 4, 4X (Stainless Steel only), 12, & 13 D Technical Details Maximum Working Voltage: 600 Volts Maximum Current: 5 Amps Terminal Blocks: EN50019 Certified - Blue Colored 12 1 10 1 TSC4X6-060604I For Enclosure Dimensions see Catalog Page 3B–48 18 1 14 1 TSC4X6-070704I 3B–49 22 1 19 1 TSC4X6-080804I 3B–50 32 1 27 1 TSC4X6-101006I 3B–51 32 1 27 1 TSC4X6-101008I 3B–52 42 1 35 1 TSC4X6-120604I 3B–53 42 1 35 1 TSC4X6-120605I 3B–54 42 1 35 1 TSC4X6-120805I 3B–55 42 1 35 1 TSC4X6-120806I 3B–56 84 2 70 2 TSC4X6-121206I 3B–57 84 2 70 2 TSC4X6-121208I 3B–58 114 2 96 2 TSC4X6-151506I 3B–59 114 2 96 2 TSC4X6-151508I 3B–60 124 2 104 2 TSC4X6-161206I 3B–61 124 2 104 2 TSC4X6-161208I 3B–62 180 3 150 3 TSC4X6-161606I 3B–63 180 3 150 3 TSC4X6-161608I 3B–64 2.5mm5 Terminals Max. Qty. # of Rows SS316L Catalog Numbers 4mm5 Terminals Max. Qty. # of Rows 3E–3 1. All quantities shown are for terminal blocks installed in vertical rows. 2. For Stainless Steel 304 assemblies substitute TSC4X6 prefix with TSC4X prefix. 3. For Steel Powder Coated assemblies substitute TSC4X6 prefix with TSC4 prefix. 4. For Gland Plates (available only on enclosures with depths greater than 6 inches) add the following suffixes: -A: Gland Plate installed on top of box -B: Gland Plate installed on bottom of box -C: Gland Plate installed on left of box -D: Gland Plate installed on right of box For multiple Gland Plates omit dashes. (i.e. TSC4X6-161608I-ABCD) 168 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 E 12/9/01 10:56 AM Page 169 TFG Series - Intrinsically Safe Circuits Certifications 0539 II 2GD EEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Ex e II T6 (T5 Tamb +55°C) Class I, Zone 1, AEx e II T6 (T5 Tamb +55°C) (T4 Tamb +70°C) Class II, Division 2 IEC60529: IP66 UL50: Type 4X, 12, & 13 D Technical Details Maximum Working Voltage: 600 Volts Maximum Current: 5 Amps 8 1 TFG-060604I For Enclosure Dimensions see Catalog Page 3B–80 1 8 1 TFG-060606I 3B–81 1 18 1 TFG-080604I 3B–82 20 1 18 1 TFG-080606I 3B–83 30 1 25 1 TFG-100804I 3B–84 30 1 25 1 TFG-100806I 3B–85 40 1 35 1 TFG-121005I 3B–86 2.5mm5 Terminals Max. Qty. # of Rows 10 1 10 20 Catalog Numbers 4mm5 Terminals Max. Qty. # of Rows 40 1 35 1 TFG-121006I 3B–87 100 2 80 2 TFG-141206I 3B–88 100 2 80 2 TFG-141207I 3B–89 120 2 100 2 TFG-161406I 3B–90 120 2 100 2 TFG-161407I 3B–91 210 3 180 3 TFG-181608I 3B–92 210 3 180 3 TFG-181610I 3B–93 240 3 210 3 TFG-201608I 3B–94 240 3 210 3 TFG-201610I 3B–95 3E–4 Terminal Blocks: EN50019 Certified - Blue Colored 1. All quantities shown are for terminal blocks installed in vertical rows. 169 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.3 E 12/9/01 10:56 AM Page 170 Quick Reference Guide METHODS OF PROTECTION Area Division 1 Division 2 Area Zone 0 Zone 1 Zone 2 Protection Method UL CSA CENELEC Explosionproof Intrinsically Safe (2 Fault) Purge/Pressurized (Type X or Y) Nonincendive Non-sparking device Purge/Pressurized (Type Z) Hermetically sealed Any Class I, Division 1 Method Protection Method Intrinsically Safe 'ia' (2 Fault) Flameproof 'd' Increased Safety 'e' Intrinsically Safe 'ib' (1 Fault)0 Encapsulation 'm' Oil Immersion 'o' Purged/Pressurized 'p' Powder filling 'q' Any Zone 0 Method Non-sparking 'nA' Hermetically sealed 'nC' Nonincendive 'nC' Restricted breathing 'nR' Any Zone 0 or 1 Method ANSI/UL 1203 CSA-30 -- -- ANSI/UL 913 CSA-157 -- -- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 UL 1604 CSA-213 CSA-213 --- --- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 CSA-213 -- -- -- -- -- -- UL (AEx) CSA (Ex) CENELEC (EEx) IEC (Ex) UL 2279 Pt. 11 CSA-E79-18 EN 50028 IEC 60 079-18 UL 2279 Pt. 1 UL 2279 Pt. 7 CSA-E79-1 CSA-E79-7 EN 50018 EN 50019 IEC 60 079-1 IEC 60 079-7 UL 2279 Pt. 11 CSA-E79-11 EN 50020 IEC 60 079-11 UL 2279 Pt. 18 UL 2279 UL 2279 Pt. 2 UL 2279 -UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 -- CSA-E79-18 CSA-E79-6 CSA-E79-2 CSA-E79-5 -CSA-E79-15 CSA-E79-15 CSA-E79-15 CSA-E79-15 -- EN 50028 EN 50015 EN 50016 EN 50017 -prEN 50021 prEN 50021 prEN 50021 prEN 50021 -- IEC 60 079-18 IEC 60 079-6 IEC 60 079-2 IEC 60 079-5 -IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 -- TEMPERATURE CLASSES AREA CLASSIFICATIONS Ignitable Materials Present Continuously Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Zone 0 (Zone 20 Dust) Zone 0 Division 1 Zone 1 (Zone 21 Dust) Zone 1 Division 1 Zone 2 (Zone 22 Dust) Zone 2 Division 2 IEC/CENELEC NEC 505 NEC 500 ATEX Classification by Group & Category According to Use Ignitable Materials Present Continuously Equipment Group II Category 1 Equipment (surface) Equipment Group I Category M1 Equipment (mining) IEC Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Category 2 Equipment Category 3 Equipment Category M2 Equipment — GAS GROUPINGS Gas, Dust or Fiber NEC 505/IEC/CENELEC NEC 500 Acetylene Hydrogen Ethylene Propane Methane Metal Dust Coal Dust Grain Dust Fibers Group IIC Group IIC/Group IIB+H2 Group IIB Group IIA Group I (firedamp) None None None None Class I/Group A Class I/Group B Class I/Group C Class I/Group D Class I/Group D Class II/Group E Class II/Group F Class II/Group G Class III ACRONYMS CENELEC - European Committee for Electrotechnical Standardization IEC - International Electrotechnical Commission NEC - National Electrical Code U.L. - Underwriters Laboratories C.S.A. - Canadian Standards Association FM - Factory Mutual BASEEFA - British Approvals Service for Electrical Apparatus in Flammable Atmospheres NFPA - National Fire Protection Agency ISO - International Organization for Standardization ANSI - American National Standard Institute ATEX - Atmospheres Explosibles Maximum Surface Temperature NEC 505 IEC CENELEC 450°C 300°C 280°C 260°C 230°C 215°C 200°C 180°C 165°C 160°C 135°C 120°C 100°C 85°C T1 T2 T3 T4 T5 T6 NEC 500 T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 INGRESS PROTECTION (IP XX) CODES # First Number (Protection against Solid Bodies) Second Number (Protection against Liquids) 0 1 2 3 4 5 6 7 8 No protection Objects greater than 50mm Objects greater than 12mm Objects greater than 2.5mm Object greater than 1mm Dust Protected Dust-tight --- No protection Vertically dripping water 75-90 Deg. dripping water Sprayed water Splashed water Water jets Heavy seas Effects of immersion Indefinite immersion 15599 Sec.4 12/9/01 10:59 AM Page 171 XIH Explosionproof Instrument Housing 4A–1 Largest Product Line Available Anywhere! ! NEW XIHMK 316SS & Aluminum 39/16" ID XIHL & XDHL 4" ID Aluminum XIHM 39/16" & 35/8" ID Aluminum XDHM 35/8" ID Aluminum XIH & XDH 33/16" ID Aluminum XIHS 25/8" ID Aluminum XDF Custom Digital Enclosure (ATEX available on some models) 171 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 172 XIHMK Explosionproof Instrument Housing (316 Stainless or Aluminum) 3 9/16" ID Enclosure Solid Cover Arrangements Glass Cover Arrangements 4 1⁄4" 4 3⁄4" 3 9⁄16" 3 9⁄16" 3 5⁄16" 3 1⁄16" Catalog Number Description XIHMKFCX Flat Cover 3⁄4" NPT Hubs Catalog Number Description XIHMKFGCX Flat Glass Cover 3⁄4" NPT Hubs Standard Features XIHMK housings accommodate large diameter assemblies, multi-level circuit boards or wide angle readouts and displays. The 3-9 ⁄ 16" ID provides maximum clearance to facilitate instrument mounting, calibration or service. Precision machined from sand-cast, copper-free aluminum. XIHMK housings feature: 5" 5 5⁄32" • 3⁄4" NPT conduit feed-through hubs offset for maximum clearance and capacity • 7⁄16" thick base for blind tapped instrument mounting holes in any location 4A–2 • Glass cover models have a large 2-1/2" diameter, tempered glass window for local read out • 45° chamfer on window opening provides enhanced viewing angle 51⁄ 2" • Buna-N rubber gasket for NEMA 4X watertight applications Certifications • Front boss for use as additional conduit or sensor entry • Corrosion resistant, “safety blue” polyester powder coating (other colors available) FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 • Internal and external ground screws and tamper resistant cover set screw for extra safety UL STANDARD 1203 • Stainless steel hardware DEMKO CENELEC STANDARD EN 50014, 50018 Design Options • Mounting lugs with 5⁄16" holes • Additional small hole drilling and tapping in the backwall for mounting of instrumentation Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIC, IP66 NEMA 4X, 7BCD, 9EFG • 1⁄2" NPT or 3⁄4" NPT opening into back wall for conduit, sensor or probe • Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT; 1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm for sensor, probe or conduit entry • 1⁄2" NPT reducers are available – add suffix “2” to catalog number 172 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 173 XIHL (Explosionproof Instrument Housing — Large) 4" ID Enclosure Solid Cover Arrangements Glass Cover Arrangements 5 1⁄8" 5 5⁄8" 4" 4" 3 3⁄4" 4" Standard Features Catalog Number Description XIHLFCX Flat Cover 3⁄4" NPT Hubs Catalog Number XIHL housings accommodate large diameter assemblies, multi-level circuit boards or wide angle readouts and displays. The 4" ID provides maximum clearance to facilitate instrument mounting, calibration or service. Precision machined from sand-cast copper-free aluminum. Description XIHLFGCX Flat Glass Cover 3⁄4" NPT Hubs XIHL housings feature: 6" 7 1⁄8" 5 3⁄4" 7 5⁄8" • 3⁄4" NPT conduit feed-through hubs offset for maximum clearance and capacity • 1⁄ 2" thick base for blind tapped instrument mounting holes in any location 4" • Glass cover models have a large 3 5⁄16" diameter, tempered glass window for local read out 4" • Buna-N rubber gasket for NEMA 4X watertight applications Catalog Number Description Catalog Number XIHLDCX Dome Cover 3⁄4" NPT Hubs XIHLDGCX Description Dome Glass Cover 3⁄4" NPT Hubs 4A–3 • Corrosion resistant, “safety blue” polyester powder coating (other colors available) • Internal and external ground screws and tamper resistant cover set screw for extra safety • Stainless steel hardware 5 7⁄16" Design Options • Four 1⁄4–20 UNC holes in front boss for bracket mounting 5" 5 5⁄8" • Front Boss Modifications: 1⁄ 2" to 1" NPT, 1⁄ 2" to 3⁄4" NPSM or 20 mm for sensor, probe or conduit entry. Consult factory for other sizes. • 1⁄ 2" NPT reducers are available – add suffix “2” to catalog number Certifications 4 1⁄16" 5⁄16" Diameter Mounting Lugs FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 UL STANDARD 1203 Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIC, IP66 NEMA 4X, 7BCD, 9EFG KEMA CENELEC STANDARD EN 50014, 50018 173 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 174 XDHL (Explosionproof Double-Ended Housing — Large) 4" ID Enclosure Solid Cover Arrangements 4" 4" 5" 4" 13⁄16" Standard Features 2 1⁄8" XDHL housings are designed to isolate incoming power connections from instrumentation. The 4" ID provides maximum clearance to facilitate instrument mounting, calibration or service, with back-to-back chambers separated by a solid, 1⁄ 2" thick wall. Precision machined from sand-cast, copper-free aluminum. Glass Cover Arrangements Catalog Number Description XDHLFCX Flat Cover 3⁄4" NPT Hubs 5 1⁄2" 3 3⁄4" 13⁄16" 2 1⁄8" 2 5⁄8" Catalog Number 2 5⁄8" Description XDHLFGCX Flat Glass Cover 3⁄4" NPT Hubs XDHL housings feature: • 3⁄4" NPT conduit feed-through hubs, offset into power side for maximum clearance and capacity • Front boss with 3⁄4" NPT opening into instrument side for conduit, sensor or probe (see design options for other sizes) 7" 71⁄2" 4" 4" • Internal and external ground screws and tamper resistant cover set screws for extra safety 6" 13⁄16" • A choice of solid covers or 3 5⁄16" diameter tempered glass window for local read out and display 4A–4 2 1⁄8" • Buna-N rubber gasket for NEMA 4X watertight applications • Corrosion resistant, “safety blue” polyester powder coating (other colors available) Catalog Number • Stainless steel hardware 13⁄16" Catalog Number XDHLDCX Dome Cover 3⁄4" NPT Hubs Design Options 2 1⁄8" 2 5⁄8" Description 5 3⁄4" Description XDHLDGCX Dome Glass Cover 3⁄4" NPT Hubs 53⁄8" • 2- to 12-point, power side terminal strip with sealed pass-through to instrument (add suffix “2T”, “4T”, “6T”, “8T”, “10T” or “12T” to catalog number) 1 5⁄ 16" • Internal wall can be modified (Drilled & Tapped) to suit design needs – please consult factory • Power side cover options: Flat Solid Dome Glass Flat Glass Dome Solid — — — — 5 5⁄8" Standard Add Suffix “A” Add Suffix “B” Add Suffix “C” • Front Boss Modifications: 1⁄ 2", 3 ⁄4" or 1" NPT; 1⁄ 2", 3 ⁄4" or 1" NPSM; or 20mm, 25mm or 30mm for sensor, probe or conduit entry 2 5⁄8" 2 1⁄4" Certifications FM STANDARD 3615 • 1⁄ 2" NPT reducers are available – add suffix “2” to catalog number CSA STANDARD C22.2 NO. 30 Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIB+H2, IP66 NEMA 4X, 7BCD, 9EFG UL STANDARD 1203 • Four 1⁄4–20 UNC holes in front boss for bracket mounting. (Consult factory for other sizes) KEMA CENELEC STANDARD EN 50014,50018 174 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 175 XIHM (Explosionproof Instrument Housing — Medium) 3 9/16" ID Enclosure (Standard) 3 5/8" ID Enclosure (Available - see note) Solid Cover Arrangements 4 1⁄4" Glass Cover Arrangements * 4 3⁄4" 3 9⁄16" 3 9⁄16" * Standard Features 3 1⁄16" XIHM housings accommodate large diameter assemblies, multi-level circuit boards or wide angle readouts and displays. The 3 9⁄16" ID provides maximum clearance to facilitate instrument mounting, calibration or service. Precision machined from sand-cast, copper-free aluminum. XIHM housings feature: * Midsize solid cover available – add 11/16" to above dimensions. * Catalog Number Description XIHMFCX Flat Cover 3⁄4" NPT Hubs XIHMMCX Mid Size Cover 3/4" NPT Hubs Catalog Number Description XIHMFGCX Flat Glass Cover 3⁄4" NPT Hubs 6 3⁄8" 4 3⁄4" 6 11⁄16" 7 5⁄8" 3 9⁄16" 3 9⁄16" Catalog Number Catalog Number Description XIHMDCX Dome Cover 3⁄4" NPT Hubs Description XIHMDGCX Dome Glass Cover 3⁄4" NPT Hubs Design Options 5" 5 1⁄4" 4 5⁄8" 3 7⁄ 8" Certifications FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIC, IP66 NEMA 4X, 7BCD, 9EFG • 3⁄4" NPT conduit feed-through hubs offset for maximum clearance and capacity • 7⁄ 16" thick base for blind tapped instrument mounting holes in any location • Glass cover models have a large 2 5⁄8" diameter, tempered glass window for local read out • 60° chamfer on window opening provides enhanced viewing angle • Buna-N rubber gasket for NEMA 4X watertight applications • Front boss for bracket mounting or for use as additional conduit or sensor entry • Corrosion resistant, “safety blue” polyester powder coating (other colors available) • Internal and external ground screws and tamper resistant cover set screw for extra safety • Stainless steel hardware 4A–5 3 5⁄16" UL STANDARD 1203 DEMKO CENELEC STANDARD EN 50014, 50018 • Mounting lugs with 5⁄16" holes (add suffix “L” to catalog number) • Additional small hole drilling and tapping in the backwall for mounting of instrumentation • 1⁄2" NPT or 3⁄4" NPT opening into back wall for conduit, sensor or probe • Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT; 1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm for sensor, probe or conduit entry • Throat diameter can be increased to 3 5⁄8" – please consult factory • Glass window covers designed for Groups C and D only (CENELEC: EExd IIB) are also available – please consult factory for pricing • 1⁄ 2" NPT reducers are available – add suffix “2” to catalog number • Four 1⁄4–20 UNC holes in front boss for bracket mounting. (Consult factory for other sizes.) 175 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 176 XDHM (Explosionproof Double-Ended Housing — Medium) 3 5/8" ID Enclosure Solid Cover Arrangements 3 5⁄8" 4 5⁄16" Glass Cover Arrangements * * 3 5⁄16" 13⁄16" 4 13⁄16" 3 5⁄8" 3 1⁄16" 13⁄16" Standard Features XDHM housings are designed to isolate incoming power connections from instrumentation. The 3 5⁄8" ID provides maximum clearance to facilitate instrument mounting, calibration or service, with back-to-back chambers separated by a solid, 1⁄2" thick wall. Precision machined from sand-cast, copper-free aluminum. XDHM housings feature: 4A–6 • 3⁄4" NPT conduit feed-through hubs, offset into power side for maximum clearance and capacity • Front boss with 3⁄4" NPT opening into instrument side for conduit, sensor or probe (see design options for other sizes) • Internal and external ground screws and tamper resistant cover set screws for extra safety • A choice of solid covers or 2 5⁄8" diameter tempered glass window for local read out and display • 60° chamfer on window opening provides enhanced viewing angle • Buna-N rubber gasket for NEMA 4X watertight applications • Corrosion resistant, “safety blue” polyester powder coating (other colors available) • Stainless steel hardware * 1 7⁄16" * • 2- to 8-point, power side terminal strip with sealed pass-through to instrument (add suffix “2T”, “4T”, “6T” or “8T” to catalog number) • Internal wall can be modified (drilled & tapped) to suit design needs - please consult factory • Power side cover options: — — — — — Description XDHMFCX Flat Cover 3⁄4" NPT Hubs XDHMMCX Mid Size Cover 3/4" NPT Hubs 115⁄16" Catalog Number Description XDHMFGCX Flat Glass Cover 3⁄4" NPT Hubs * 6 7⁄16" 7 11⁄16" 3 5⁄8" 3 5⁄8" 13⁄16" 4 3⁄4" 6 11⁄16" 13⁄16" *1 7⁄16" * 1 7⁄16" 115⁄16" Catalog Number Description XDHMDCX Dome Cover 3⁄4" NPT Hubs 115⁄16" * * Catalog Number Description XDHMDGCX Dome Glass Cover 3⁄4" NPT Hubs 5" Standard Add Suffix “A” Add Suffix “B” Add Suffix “C” Add Suffix “D” • Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT; 1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm opening modify for sensor, probe or conduit entry • Glass window covers designed for Groups C and D only (CENELEC: EExd IIB) are also available – please consult factory for pricing • Catalog Number * 1 7⁄16" * * Midsize solid cover available – add 11/16" to above dimensions. Design Options Flat Solid Dome Glass Flat Glass Dome Solid Midsize Solid 115⁄16" 5 1⁄4" 1 1⁄ 8" 2 1⁄4" Certifications 1⁄ 2" NPT reducers are available – add suffix “2” to catalog number FM STANDARD 3615 Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIC, IP66 NEMA 4X, 7BCD, 9EFG CSA STANDARD C22.2 NO. 30 • Four 1⁄4–20 UNC holes in front boss for bracket mounting. (Consult factory for other sizes.) UL STANDARD 1203 DEMKO CENELEC STANDARD EN 50014, 50018 176 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 177 XIH (Explosionproof Instrument Housing) 3 3/16" ID Enclosure Solid Cover Arrangements Glass Cover Arrangements 3 7⁄16" 3 3⁄16" 3 13⁄16" 3 3⁄16" 2 9⁄16" Catalog Number XIHFCX2 XIHFCX3 2 3⁄16" Catalog Number Description Flat Cover 1⁄2" NPT Hubs Flat Cover 3⁄4" NPT Hubs 4 15⁄16" XIHFGCX2 XIHFGCX3 Description Flat Glass Cover Flat Glass Cover 5 13⁄16" 4 7⁄16" 3 3⁄16" Standard Features 1⁄2" NPT Hubs 3⁄4" NPT Hubs XIH housings are designed for small to medium size electronic assemblies. The 3 3 ⁄16" ID provides ample clearance to accommodate a wide variety of measurement and control devices. Precision machined from sand-cast copper-free aluminum. XIH housings feature: 6" • Four interior mounting bosses at 45° orientation accommodate blind tapped holes on a 2 1⁄2" bolt circle • 1⁄2" or 3 ⁄4" NPT conduit feed-through hubs, offset for maximum clearance and capacity 3 3 ⁄16" • Internal and external ground screws and tamper resistant cover set screw for extra safety XIHDCX2 XIHDCX3 Catalog Number Description Dome Cover Dome Cover 1⁄2" NPT Hubs 3⁄4" NPT Hubs XIHDGCX2 XIHDGCX3 • Glass cover models have a 2 5 ⁄8" diameter, tempered glass window for local read out Description Dome Glass Cover 1⁄2" NPT Hubs Dome Glass Cover 3⁄4" NPT Hubs 4A–7 Catalog Number • Buna-N rubber gasket for NEMA 4X watertight applications • Corrosion resistant, “safety blue” polyester powder coating (other colors available) • Stainless steel hardware 4 1⁄2" Design Options • Four 1⁄4-20 UNC holes in front boss for bracket mounting. Consult factory for other sizes. 4 1⁄8" 4 13⁄16" • Front Boss Modifications: 1⁄2" or 3 ⁄4" NPT for sensor, probe or conduit entry • Mounting lugs with 5⁄16" holes (add suffix “L” to catalog number) • Other interior mounting bosses available – please consult factory 3 1⁄4" Certifications FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIC, IP66 NEMA 4X, 7BCD, 9EFG UL STANDARD 1203 (Consult factory for availability) ISSEP CENELEC STANDARD EN 50014, 50018 177 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 178 XDH (Explosionproof Double-Ended Housing) 3 3/16" ID Enclosure Solid Cover Arrangements 3 3⁄16" 2 11⁄16" 3⁄4" 3⁄4" 1 5⁄16" 3 7⁄8" 3 3⁄16" 3 1⁄2" 2 5⁄16" 1 5⁄16" 17⁄8" Standard Features XDH housings are designed to isolate incoming power connections from instrumentation. The 3 3⁄16" ID provides ample clearance to accommodate a wide variety of measurement and control devices, with back-to-back chambers separated by a solid, 3⁄8" thick wall. Precision machined from sand-cast copper-free aluminum. XDH housings feature: Glass Cover Arrangements 17⁄8" Catalog Number Description Catalog Number Description XDHFCX Flat Cover 3⁄4" NPT Hubs XDHFGCX Flat Glass Cover 3⁄4" NPT Hubs • 3⁄4" NPT conduit feed-through hubs, offset into power side for maximum clearance and capacity 5 7⁄8" • Front boss with 3⁄4" NPT opening into instrument side for conduit, sensor or probe (see design options for other sizes) 6 1⁄16" 3 3⁄16" 3 3⁄16" 3⁄4" • Internal and external ground screws and tamper resistant cover set screws for extra safety 5 1⁄16" 3⁄4" 1 5⁄16" 4A–8 • Buna-N rubber gasket for NEMA 4X watertight applications • Corrosion resistant, “safety blue” polyester powder coating (other colors available) • Stainless steel hardware 1 5 ⁄16" 17⁄8" • A choice of solid covers or 2 5⁄8" diameter tempered glass window for local read out and display 4 9⁄16" 17⁄8" Catalog Number Description Catalog Number Description XDHDCX Dome Cover 3⁄4" NPT Hubs XDHDGCX Dome Glass Cover 3⁄4" NPT Hubs 4 1⁄2" Design Options • 2- or 4-point, power side terminal strip with sealed pass-through to instrument (add suffix “2T” or “4T” to catalog number) 13⁄ 16" 4 11 ⁄16" • Power side cover options: Flat Solid — Standard Dome Glass — Add Suffix “A” Flat Glass — Add Suffix “B” Dome Solid — Add Suffix “C” 2 1⁄4" • Four 1⁄4–20 UNC holes in front boss for bracket mounting. (Consult factory for other sizes.) • Front Boss Modifications: 1⁄ 2" or 3⁄ 4" for sensor, probe or conduit entry • 1⁄ 2" NPT conduit entries are available – add suffix “2” to catalog number. Certifications Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIC, IP66 NEMA 4X, 7BCD, 9EFG FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 ISSEP CENELEC STANDARD EN 50014, 50018 178 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.4 12/9/01 10:59 AM Page 179 XIHS (Explosionproof Instrument Housing — Small) 2 5/8" ID Enclosure Cover Arrangements 4" 3⁄16" 3 1 ⁄2" 3 1 ⁄2" 3 1 ⁄2" Flat Cover Dome Cover Dome Glass Cover Catalog Number Base Styles Conduit Size 1⁄2" “B” XIHSBFC2 XIHSBFC3 XIHSBFC4 XIHSCFC2 XIHSCFC3 XIHSCFC4 1⁄2" “C” “D” XIHSDFC3 XIHSDFC4 3⁄4" XIHSLFC2 XIHSLFC3 XIHSLFC4 1⁄2" “L” “T” XIHSTFC2 XIHSTFC3 XIHSTFC4 1⁄2" XIHSXFC2 XIHSXFC3 XIHSXFC4 1⁄2" “X” NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" NPT 1" NPT NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" XIHSYFC23 ONE 1⁄2" NPT ONE 3⁄4" NPT “Y” 2 5⁄8" 2 5⁄8" 2 5⁄8" 5 3⁄4" Catalog Number Conduit Size Catalog Number Conduit Size XIHSBDC2 XIHSBDC3 XIHSBDC4 1⁄2" XIHSBDGC2 XIHSBDGC3 XIHSBDGC4 1⁄2" XIHSCDC2 XIHSCDC3 XIHSCDC4 1⁄2" XIHSCDGC2 XIHSCDGC3 XIHSCDGC4 1⁄2" XIHSDDC3 XIHSDDC4 3⁄4" XIHSDDGC3 XIHSDDGC4 3⁄4" XIHSLDC2 XIHSLDC3 XIHSLDC4 1⁄2" XIHSLDGC2 XIHSLDGC3 XIHSLDGC4 1⁄2" XIHSTDC2 XIHSTDC3 XIHSTDC4 1⁄2" XIHSTDGC2 XIHSTDGC3 XIHSTDGC4 1⁄2" XIHSXDC2 XIHSXDC3 XIHSXDC4 1⁄2" XIHSXDGC2 XIHSXDGC3 XIHSXDGC4 1⁄2" NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" NPT 1" NPT NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" XIHSYDC23 ONE 1⁄2" NPT ONE 3⁄4" NPT NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" NPT 1" NPT NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT 3⁄4" NPT NPT 1" NPT Standard Features XIHS housings are designed to accommodate small instruments or devices. The 2 5⁄8" ID enclosure is offered in six different conduit configurations and a choice of cover arrangements. Precision machined from sand-cast, copper-free aluminum. XIHS housings feature: • • • • • 3⁄4" XIHSYDGC23 ONE 1⁄2" NPT ONE 3⁄4" NPT • 1⁄2", 3⁄4" or 1" NPT conduit feed-through hubs for power Internal ground screw Interior instrument mounting bosses that accommodate blind tapped holes on a 2" bolt circle Glass cover arrangements with a 1 1⁄8" diameter tempered glass window for local read out Buna-N rubber gasket for NEMA 4X watertight applications Tumblast, natural aluminum finish Design Options • Corrosion resistant, “safety blue” polyester powder coating (other colors available) Certifications Note: Above dimensions are for 1/2" and 3/4" NPT. For 1" NPT housings, add 5/16" to height dimensions. FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 Class I, Groups B, C and D Class II, Groups E,F,G Class III NEMA 4X, 7BCD, 9EFG UL STANDARD 1203 E A C E E A C D D B F “D” “B” CONDUIT SIZE A B C D E F 1/2 3 1/2 2 1/16 2 5/8 1 11/16 7/8 7/8 3/4 3 1/2 2 1/16 2 5/8 1 11/16 7/8 7/8 1 3 1/2 2 3/8 2 5/8 1 1 2 ADALET Enclosure Systems • Designing Our Products Around Yours SM 179 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 4A–9 2 5⁄8" 1 11⁄16" 4 1⁄16" 5 1⁄16" 15599 Sec.4 12/9/01 10:59 AM Page 180 XDF Custom Enclosure Systems For Digital Instrumentation Applications Environments requiring explosionproof or dust-tight enclosures. Housing for panel mounted instrumentation with or without external operator functions – can accommodate standard DIN or other size devices. Examples • Flow Meters • Level Indicators • Motion Controllers • Temperature Monitors • Gas Analyzers Features • Space saving rectangular design • Enclosure dimensions customized to match the instrument • A range of rectangular window openings • Choice of quantity and location of miniature operators including “key pad” configuration • Front or rear accessibility for instrument service • Watertight NEMA 4 gasketing • Choice of surface finishes • Recessed Allen Head cover bolts for appearance and security 4B–1 • Special nameplating and escutcheon available. Availability & Support Adalet engineering will review your specific requirements. Adalet offers design support, custom dimensional layout, product prototyping, testing and certification assistance. Production scheduling and inventory to match defined needs. Custom sizes available, consult factory for details. Certifications FM STANDARD 3615 CSA STANDARD C22.2 NO. 30 NEMA 4, 7CD, 9E, F & G NEC Class I, Division I, Groups C & D Class II, Groups E, F & G NEMA 4, 7CD, 9E, F, & G 180 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 181 XCE & XJF Explosionproof Enclosures XCE EXPLOSIONPROOF CONTROL ENCLOSURES XJF EXPLOSIONPROOF JUNCTION BOXES FLANGED Design Options • CENELEC flameproof optional – designate XCEX when ordering. Includes external earthing assembly. • Quad-lead bolt (quick thread bolt) option - designate XCEQ when ordering. Not available with XCEX. • NEMA 4 (WATERTIGHT)/IP66: Features a nitrile O-Ring retained in the cover flange in a machined groove. When ordering, add N4 to the catalog number. *This option may affect certifications - consult factory. • NEMA 6 (SUBMERSIBLE): Consult factory. • Cast-on mounting buttons, bosses and pads: Per customer specifications. • Captive cover bolts: Consult factory. • Hinges: May be installed for removable or non-removable cover. Left side standard, other locations optional. • Windows: Circular window sizes ranging from 1" to 8" diameter viewing area. Rectangular window sizes ranging from 3" x 3" to 13" x 13" viewing area. • Stainless steel cover bolts. Consult factory for NEMA 4X rating. • Mounting Pans: Available in galvanized steel, aluminum or phenolic. Applications: Adalet XCE series and XJF enclosures are used in the installation of electrical/electronic components for control, measurement or monitoring applications in hazardous environments. XCE control enclosures can be modified for installation of a variety of explosionproof operator devices, viewing windows and accessories permitting the development of customized enclosure systems. • Sidewall auxiliary device installation or machining available on XCE/XCEQ/XCEX series enclosures – Consult Factory. • Factory machined metric sidewall threads approved on XCE and XCEX series for Groups C & D only. • The Adalet engineering department is available to assist in the selection of custom explosionproof enclosures for your products. Features • Integral, cast-on mounting lugs, slotted for ease of field installation. 5A–1 • Copper-free aluminum, lightweight and corrosion resistant. Certifications • Uniform wall thickness for ease of installation of control devices, windows and conduit openings. XCE Series Control Enclosures • External flange provides maximum accessibility of components mounted inside. UL STANDARD 1203 CSA STANDARD C22.2 NO. 30 • Tumblast finish for quality appearance. EN 5O 018 (XCEX) XJF Junction Boxes CSA STANDARD C22.2 NO. 30 UL STANDARD 886 • Premium high strength steel cover bolts, plated and coated for maximum corrosion resistance (stainless steel optional). • Enclosures certified drillable for conduit entrances in the factory or the field. Class I, Groups B,C,D Class II, Groups E,F,G Class III CENELEC: EExd IIB, (Specify XCEX) ATEX Certifications available – Consult Factory. NEMA 4, 7B*CD, 9EFG • Internal grounding screw standard. • Covers exceeding approximately 75 lbs. are provided with two removable eye bolts for ease of handling. Some sizes and option combinations may not be certified. Consult Factory for specific certifications and file numbers. • XCE/XCEQ/XCEX certified drillable for operators at the factory or in the field. • IP40 standard on XCEX without gasket. ADALET Enclosure Systems • Designing Our Products Around Yours 181 SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 182 XCE & XJF Explosionproof Enclosures XCE/XJF Catalog Number Inside Nominal Dimensions W L D Usable Inside Depth Mtg. Bolt Size Apprx. Shipping Weight, lbs. 041604 4 16 4 4 3/4 7 1/4 19 1/4 6 12 1/8 6 3/4 3/8 25 060804 6 8 4 4 5/8 9 1/4 11 1/4 5 15/16 060805 6 8 5 5 5/8 9 1/4 11 1/4 6 15/16 4 1/2 9 1/8 3/8 21 4 1/2 9 1/8 3/8 23 060806 6 8 6 6 5/8 9 1/4 11 1/4 061105 6 11 5 5 7/8 9 1/4 14 1/4 7 15/16 4 1/2 9 1/8 3/8 25 7 3/16 7 1/2 9 1/8 3/8 24 061204 6 12 4 4 3/4 9 1/4 061206 6 12 6 6 3/4 9 1/4 15 1/4 6 1/16 8 1/2 9 1/8 3/8 24 15 1/4 8 1/16 8 1/2 9 1/8 3/8 29 061305 6 13 5 5 7/8 9 1/4 16 1/4 7 3/16 9 1/2 9 1/8 3/8 26 071004 7 10 4 4 3/4 10 3/8 13 3/8 6 3/16 6 1/2 9 3/4 3/8 27 071006 7 10 6 1/8 6 3/4 10 3/8 13 3/8 8 3/16 6 1/2 9 3/4 3/8 31 071805 7 18 1/4 5 5 3/4 10 3/8 21 5/8 7 3/16 14 1/2 9 3/4 3/8 55 080804 8 8 4 4 13/16 11 3/8 11 3/8 6 3/8 4 1/4 11 3/8 24 080806 8 8 6 6 13/16 11 3/8 11 3/8 8 3/8 4 1/4 11 3/8 28 080808 8 8 8 8 13/16 11 3/8 11 3/8 10 3/8 4 1/4 11 3/8 35 081004 8 10 4 4 3/4 11 3/8 13 3/8 6 1/4 6 1/2 10 3/4 3/8 30 081006 8 10 6 6 3/4 11 3/8 13 3/8 8 1/4 6 1/2 10 3/4 3/8 34 Overall Dimension A B C Mounting Lug CL to CL E F 081008 8 10 8 8 3/4 11 3/8 13 3/8 10 1/4 6 1/2 10 3/4 3/8 39 081204 8 12 4 4 3/4 11 3/8 15 3/8 6 1/4 8 1/2 10 3/4 3/8 34 081206 8 12 6 6 3/4 11 3/8 15 3/8 8 1/4 8 1/2 10 3/4 3/8 42 081208 8 12 8 8 3/4 11 3/8 15 3/8 10 1/4 8 1/2 10 3/4 3/8 48 091105 9 11 5 5 3/4 12 3/8 14 3/8 7 5/16 7 1/2 12 3/8 41 101004 10 10 4 4 3/4 13 3/8 13 3/8 6 5/16 6 1/2 13 3/8 34 • To indicate Quad-Lead bolt option, add suffix "Q" after XCE. (Not available on XCEX models.) 101006 10 10 6 6 3/4 13 3/8 13 3/8 8 5/16 6 1/2 13 3/8 44 101008 10 10 8 8 3/4 13 3/8 13 3/8 10 5/16 6 1/2 13 3/8 50 • Operators, windows and hinges are ordered separately. 101206 10 12 6 1/4 7 1/4 13 3/8 15 3/8 8 7/8 8 1/2 13 1/4 3/8 46 101404 10 14 4 4 3/4 13 3/8 17 3/8 6 7/16 10 5/8 13 1/4 3/8 42 • To indicate EEx d approval specify XCEX. 101406 10 14 6 6 3/4 13 3/8 17 3/8 8 7/16 10 5/8 13 3/8 49 101408 10 14 8 8 3/4 13 3/8 17 3/8 10 1/2 10 5/8 13 3/8 57 101410 10 14 8 10 13/16 13 3/8 17 3/8 12 7/16 10 5/8 13 3/8 70 121204 12 12 4 5 16 1/4 16 1/4 6 15/16 8 5/8 15 3/4 1/2 60 121206 12 12 6 7 16 1/4 16 1/4 8 15/16 8 5/8 15 3/4 1/2 68 121208 12 12 8 9 16 1/4 16 1/4 10 15/16 8 5/8 15 3/4 1/2 80 121804 12 18 4 4 3/4 16 1/4 22 1/4 6 3/4 14 1/8 15 3/4 1/2 85 121806 12 18 6 6 3/4 16 1/4 22 1/4 8 3/4 14 1/8 15 3/4 1/2 93 121808 12 18 8 8 3/4 16 1/4 22 1/4 10 3/4 14 1/8 15 3/4 1/2 101 122005 12 20 5 5 3/4 16 1/4 24 1/4 8 1/8 14 3/8 15 3/4 1/2 104 122404 12 24 4 4 15/16 16 1/4 28 1/4 7 1/4 18 3/8 15 3/4 1/2 116 122406 12 24 6 6 15/16 16 1/4 28 1/4 9 1/4 18 3/8 15 3/4 1/2 127 • To indicate NEMA 4/IP66 option, add suffix “N4” after size (catalog number). 5A–2 Note: All dimensions are in inches and are nominal enclosure size only. Inside nominal dimensions are at flange. Consult factory for exact dimensions. * *Approval Pending – Consult Factory. 182 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 183 XCE & XJF Explosionproof Enclosures * * * * * * Inside Nominal Dimensions W L D Usable Inside Depth 122408 12 24 8 8 15/16 122410 12 24 123006 12 30 123604 12 123606 12 123608 124608 Mounting Lug CL to CL E F Overall Dimension A B C 16 1/4 15 3/4 Mtg. Bolt Size Apprx. Shipping Weight, lbs. 1/2 140 28 1/4 11 1/4 18 3/8 10 10 15/16 16 1/4 28 1/4 13 1/4 18 3/8 15 3/4 1/2 154 6 6 11/16 16 3/4 34 1/4 9 5/8 23 15 3/4 1/2 180 36 4 4 15/16 16 1/4 40 1/4 7 11/16 29 15 3/4 1/2 192 36 6 6 15/16 16 1/4 40 1/4 9 11/16 29 15 3/4 1/2 212 12 36 8 8 15/16 16 1/4 40 1/4 11 11/16 29 15 3/4 1/2 232 12 46 8 8 15/16 16 1/4 50 1/4 11 11/16 39 15 3/4 5/8 280 141404 14 14 4 5 18 1/4 18 1/4 7 1/8 9 3/4 17 3/4 1/2 91 141406 14 14 6 7 18 1/4 18 1/4 9 1/4 9 3/4 17 3/4 1/2 97 141408 14 14 8 9 18 1/4 18 1/4 11 1/8 9 3/4 17 3/4 1/2 103 142210 14 22 10 11 1/4 18 1/4 26 1/4 13 5/8 16 1/2 17 3/4 1/2 181 142213 14 22 10 13 18 1/4 26 1/4 15 1/8 16 1/2 17 3/4 1/2 235 142806 14 28 6 7 13/16 18 1/4 32 1/4 9 9/16 22 1/2 17 3/4 1/2 120 161604 16 16 4 6 5/8 20 7/8 20 7/8 7 15/16 11 19 3/4 5/8 114 161606 16 16 6 7 5/8 20 7/8 20 7/8 9 15/16 11 19 3/4 5/8 135 161608 16 16 8 9 5/8 20 7/8 20 7/8 11 15/16 11 19 3/4 5/8 156 162406 16 24 6 7 13/16 20 7/8 28 7/8 10 3/8 18 3/8 19 3/4 5/8 190 162408 16 24 8 9 13/16 20 7/8 28 7/8 12 3/8 18 5/8 19 3/4 5/8 209 162410 16 24 10 11 13/16 20 7/8 28 7/8 14 3/8 18 3/8 19 3/4 5/8 225 162806 16 28 6 6 13/16 20 1/2 32 11/16 9 1/2 22 1/2 19 3/4 5/8 200 163406 16 34 6 6 15/16 20 1/2 38 1/2 9 1/2 27 19 3/4 5/8 260 163010 16 30 10 11 1/8 20 1/2 34 1/2 13 7/8 27 19 3/4 5/8 320 164610 16 46 10 11 13/16 20 7/8 50 7/8 14 9/16 39 19 3/4 5/8 390 181804 18 18 4 5 13/16 22 7/8 22 7/8 8 1/2 13 21 3/4 5/8 154 181806 18 18 6 7 13/16 22 7/8 22 7/8 10 1/2 13 21 3/4 5/8 177 181808 18 18 8 9 13/16 22 7/8 22 7/8 12 1/2 13 21 3/4 5/8 200 182406 18 24 6 7 7/16 22 7/8 28 7/8 10 13/16 18 3/8 21 3/4 5/8 226 182408 18 24 8 9 7/16 22 7/8 28 7/8 12 13/16 18 3/8 21 3/4 5/8 239 182410 18 24 10 11 7/16 22 7/8 28 7/8 14 13/16 18 3/8 21 3/4 5/8 260 183008 18 30 8 9 3/8 22 7/8 34 7/8 12 13/16 23 21 3/4 5/8 293 183608 18 36 8 9 3/8 22 7/8 40 7/8 12 7/8 29 21 3/4 5/8 318 183610 18 36 10 11 3/8 22 7/8 40 7/8 14 7/8 29 21 3/4 5/8 340 203606 20 36 6 7 1/8 24 7/8 40 7/8 10 7/8 29 24 5/8 340 203612 20 36 6 12 25 5/8 41 5/8 15 29 24 5/8 415 204806 20 48 6 7 1/8 24 7/8 52 7/8 10 7/8 41 24 5/8 430 204812 20 48 6 12 25 5/8 53 5/8 15 41 24 5/8 515 242408 24 24 8 9 7/16 28 7/8 28 7/8 12 7/16 18 3/8 28 5/8 302 242410 24 24 10 11 7/16 28 7/8 28 7/8 14 7/16 18 3/8 28 5/8 330 243008 24 30 8 9 1/4 28 7/8 34 7/8 12 15/16 23 28 5/8 356 243608 24 36 8 9 1/4 28 7/8 40 7/8 12 7/16 29 28 5/8 408 243610 24 36 10 11 1/4 28 7/8 40 7/8 14 7/8 29 28 5/8 433 243612 24 36 10 12 28 7/8 40 7/8 16 1/2 29 28 5/8 545 323612 32 36 6 12 37 3/4 41 3/4 15 1/2 29 36 1/8 5/8 691 • To indicate Quad-Lead bolt option, add suffix "Q" after XCE. (Not available on XCEX models.) • Operators, windows and hinges are ordered separately. • To indicate EEx d approval specify XCEX. • To indicate NEMA 4/IP66 option, add suffix “N4” after size (catalog number). Note: All dimensions are in inches and are nominal enclosure size only. Inside nominal dimensions are at flange. Consult factory for exact dimensions. *Approval Pending – Consult Factory. 183 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 5A–3 * * XCE/XJF Catalog Number 15599 Sec.5 A 12/11/01 6:06 PM Page 184 Bolt-On Mounting Lugs for XCE & XJF Enclosures Adjust To Irregular Mounting Surfaces Without Damaging Enclosures Adalet Bolt-On Mounting Lugs for XCE and XJF Enclosures are bi-directional, permitting either vertical or horizontal mounting orientation. The ductile aluminum alloy lugs adapt to irregular surfaces so lug bolts can be tightened without damaging the enclosure. 5A–4 184 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 185 Bolt-On Mounting Lugs Catalog Number Mounting Dimensions Optional Mounting Standard Mounting J K L M Mtg. Lug Size N Mtg. Lug Thickness T Catalog Number Mounting Dimensions Optional Mounting Standard Mounting J K L M Mtg. Lug Size N Mtg. Lug Thickness T X X 7 7/8 4 3/8 1/4 XCE124608M 7 49 15 41 1/2 3/8 XCE060805M X X 7 7/8 4 3/8 1/4 XCE141404M 9 17 17 9 1/2 3/8 XCE060806M X X 7 7/8 4 3/8 1/4 XCE141406M 9 17 17 9 1/2 3/8 XCE061105M X X 7 7/8 9 3/8 1/4 XCE141408M 9 17 17 9 1/2 3/8 XCE061204M X X 7 7/8 10 3/8 1/4 XCE142806M 9 31 17 23 1/2 3/8 XCE061206M X X 7 7/8 10 3/8 1/4 XCE161604M 11 19 19 10 15/16 1/2 3/8 XCE061305M X X 7 7/8 11 3/8 1/4 XCE161606M 11 19 19 10 15/16 1/2 3/8 XCE071004M X X 8 7/8 8 3/8 1/4 XCE161608M 11 19 19 10 15/16 1/2 3/8 XCE071006M X X 8 7/8 8 3/8 1/4 XCE162406M 11 3/8 27 1/4 19 3/8 19 3/8 1/2 3/8 XCE071805M X X 8 7/8 16 3/8 1/4 XCE162408M 11 3/8 27 1/4 19 3/8 19 3/8 1/2 3/8 XCE080804M X X 9 7/8 6 3/8 1/4 XCE162410M 11 3/8 27 1/4 19 3/8 19 3/8 1/2 3/8 XCE080806M X X 9 7/8 6 3/8 1/4 XCE162806M 11 3/8 31 3/8 19 3/8 23 1/2 3/8 XCE080808M X X 9 7/8 6 3/8 1/4 XCE163406M 11 3/8 37 3/8 19 3/8 29 3/8 1/2 3/8 XCE081004M X X 9 7/8 8 3/8 1/4 XCE164610M 11 3/8 49 3/8 19 3/8 41 3/8 1/2 3/8 XCE081006M X X 9 7/8 8 3/8 1/4 XCE181804M 13 3/8 21 3/8 21 3/8 13 3/8 1/2 3/8 XCE081008M X X 9 7/8 8 3/8 1/4 XCE181806M 13 3/8 21 3/8 21 3/8 13 3/8 1/2 3/8 XCE081204M 3 13 /16 14 3/8 10 3/8 7 13/16 1/2 3/8 XCE181808M 13 3/8 21 3/8 21 3/8 13 3/8 1/2 3/8 XCE081206M 3 13 /16 14 3/8 10 3/8 7 13/16 1/2 3/8 XCE182406M 13 27 21 19 1/2 3/8 XCE081208M 3 13 /16 14 3/8 10 3/8 7 13/16 1/2 3/8 XCE182408M 13 27 21 19 1/2 3/8 XCE091105M 4 13/16 13 3/8 11 3/8 9 1/2 3/8 XCE182410M 13 27 21 1/4 19 1/2 3/8 XCE101004M 5 13 13 5 1/2 3/8 XCE183008M 13 31 21 25 1/2 3/8 XCE101006M 5 13 13 5 1/2 3/8 XCE183608M 13 1/4 39 1/2 21 31 1/2 1/2 3/8 XCE101008M 5 13 13 5 1/2 3/8 XCE183610M 13 1/4 39 1/2 21 1/4 31 1/2 1/2 3/8 XCE101206M 5 15 13 6 1/2 3/8 XCE203606M 15 3/4 39 3/4 23 3/4 31 3/4 1/2 3/8 XCE101404M 5 17 13 9 1/2 3/8 XCE204806M 15 3/4 51 3/4 23 3/4 43 3/4 1/2 3/8 XCE101406M 5 17 13 9 1/2 3/8 XCE242408M 19 1/2 27 1/2 27 1/2 19 1/2 1/2 3/8 XCE101408M 5 17 13 9 1/2 3/8 XCE242410M 19 1/2 27 1/2 27 1/2 19 1/2 1/2 3/8 XCE101410M 5 17 13 9 1/2 3/8 XCE243008M 19 9/16 33 9/16 27 9/16 25 9/16 1/2 3/8 XCE121204M 7 15 15 7 1/2 3/8 XCE243608M 19 9/16 39 9/16 27 9/16 31 9/16 1/2 3/8 XCE121206M 7 15 15 7 1/2 3/8 XCE243610M 19 9/16 39 9/16 27 9/16 31 9/16 1/2 3/8 XCE121208M 7 15 15 7 1/2 3/8 XCE121804M 7 20 7/8 15 12 7/8 1/2 3/8 XCE121806M 7 20 7/8 15 12 7/8 1/2 3/8 XCE121808M 7 20 7/8 15 12 7/8 1/2 3/8 XCE122005M 7 22 7/8 15 14 7/8 1/2 3/8 XCE122404M 7 26 7/8 15 18 7/8 1/2 3/8 XCE122406M 7 26 7/8 15 18 7/8 1/2 3/8 XCE122408M 7 26 7/8 15 18 7/8 1/2 3/8 XCE122410M 7 26 7/8 15 18 7/8 1/2 3/8 XCE123006M 7 33 15 24 7/8 1/2 3/8 XCE123604M 7 39 15 31 1/2 3/8 XCE123606M 7 39 15 31 1/2 3/8 XCE123608M 7 39 15 31 1/2 3/8 5A–5 XCE060804M 185 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 186 XCE Series Recommended Spacing For Operators In Covers Catalog Number Standard Operators Maximum Maximum Maximum Number Number Recommended Number Operator Operators Spacing Operators Rows Per Row CL to CL Miniature Operators Maximum Maximum Maximum Number Number Number Operator Operators Operators Rows Per Row Recommended Spacing CL to CL Cover Wall Thickness (Inches) XCE041604 5 5 1 2 1/2 13 13 1 1 1/2 XCE060804 2 2 1 2 1/2 8 4 2 1 1/2 XCE060805 2 2 1 2 1/2 8 4 2 1 1/2 XCE060806 2 2 1 2 1/2 8 4 2 1 1/2 XCE061105 3 3 1 2 1/2 14 7 2 1 1/2 XCE061204 4 4 1 2 1/2 16 8 2 1 5/8 XCE061206 4 4 1 2 1/2 16 8 2 1 5/8 XCE061305 4 4 1 2 1-2 18 9 2 1 1/2 XCE071004 6 3 2 2 1/2 18 6 3 1 5/8 XCE071006 6 3 2 2 1/2 18 6 3 1 5/8 XCE071805 12 6 2 2 1/2 45 15 3 1 5/8 XCE080804 4 2 2 2 1/2 16 4 4 1 11/16 XCE080806 4 2 2 2 1/2 16 4 4 1 11/16 XCE080808 4 2 2 2 1/2 16 4 4 1 11/16 XCE081004 6 3 2 2 1/2 24 6 4 1 11/16 XCE081006 6 3 2 2 1/2 24 6 4 1 11/16 XCE081008 6 3 2 2 1/2 24 6 4 1 11/16 XCE081204 8 4 2 2 1/2 32 8 4 1 11/16 XCE081206 8 4 2 2 1/2 32 8 4 1 11/16 XCE081208 8 4 2 2 1/2 32 8 4 1 11/16 XCE091105 6 3 2 2 1/2 35 7 5 1 11/16 XCE101004 9 3 3 2 1/2 36 6 6 1 11/16 XCE101006 9 3 3 2 1/2 36 6 6 1 11/16 5A–6 XCE101008 9 3 3 2 1/2 36 6 6 1 11/16 XCE101206 12 4 3 2 1/2 48 8 6 1 3/4 XCE101404 12 4 3 2 1/2 60 10 6 1 3/4 XCE101406 12 4 3 2 1/2 60 10 6 1 3/4 XCE101408 12 4 3 2 1/2 60 10 6 1 3/4 XCE101410 12 4 3 2 1/2 60 10 6 1 3/4 XCE121204 9 3 3 3 64 8 8 1 7/8 XCE121206 9 3 3 3 64 8 8 1 7/8 XCE121208 9 3 3 3 64 8 8 1 7/8 XCE121804 15 5 3 3 92 14 8 1 15/16 XCE121806 15 5 3 3 92 14 8 1 15/16 XCE121808 15 5 3 3 92 14 8 1 15/16 XCE122005 18 6 3 3 128 16 8 1 1 1/8 XCE122404 21 7 3 3 150 20 8 1 1 1/8 XCE122406 21 7 3 3 150 20 8 1 1 1/8 XCE122408 21 7 3 3 150 20 8 1 1 1/8 Note: Closer spacing other than 21/2 & 3 inches available – Consult factory for special designs. 186 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 187 Catalog Number Standard Operators Maximum Maximum Maximum Number Number Recommended Number Operator Operators Spacing Operators Rows Per Row CL to CL XCE122410 21 XCE123006 XCE123604 Miniature Operators Maximum Maximum Maximum Number Number Number Operator Operators Operators Rows Per Row Recommended Spacing CL to CL Cover Wall Thickness (Inches) 1 1/8 7 3 3 150 20 8 1 27 9 3 3 150 26 8 1 1 3/8 33 11 3 3 150 32 8 1 1 3/16 XCE123606 33 11 3 3 150 32 8 1 1 3/16 XCE123608 33 11 3 3 150 32 8 1 1 3/16 XCE124608 42 14 3 3 150 41 8 1 1 1/4 XCE141404 16 4 4 3 100 10 10 1 7/8 XCE141406 16 4 4 3 100 10 10 1 7/8 XCE141408 16 4 4 3 100 10 10 1 7/8 XCE142210 24 6 4 3 100 18 10 1 1 1/8 XCE142213 24 6 4 3 100 18 10 1 1 1/8 XCE142806 32 8 4 3 150 24 10 1 1 1/8 XCE161604 16 4 4 3 1/2 121 11 11 1 7/8 XCE161606 16 4 4 3 1/2 121 11 11 1 7/8 XCE161608 16 4 4 3 1/2 121 11 11 1 7/8 XCE162406 24 6 4 3 1/2 150 19 11 1 7/8 XCE162408 24 6 4 3 1/2 150 19 11 1 7/8 XCE162410 24 6 4 3 1/2 150 19 11 1 7/8 XCE162806 28 7 4 3 1/2 150 24 11 1 1 1/4 XCE163010 32 8 4 3 1/2 150 26 12 1 1 1/4 XCE163406 32 8 4 3 1/2 150 30 11 1 1 1/4 XCE164610 48 12 4 3 1/2 150 41 11 1 1 XCE181804 16 4 4 3 1/2 150 13 13 1 1 XCE181806 16 4 4 3 1/2 150 13 13 1 1 XCE181808 16 4 4 3 1/2 150 13 13 1 1 XCE182406 24 6 4 3 1/2 150 19 13 1 1 1/2 XCE182408 24 6 4 3 1/2 150 19 13 1 1 1/2 XCE182410 24 6 4 3 1/2 150 19 13 1 1 1/2 XCE183008 32 8 4 3 1/2 150 25 13 1 1 1/2 XCE183608 36 9 4 3 1/2 150 31 13 1 1 7/8 XCE183610 36 9 4 3 1/2 150 31 13 1 1 7/8 XCE203606 45 9 5 3 1/2 150 31 15 1 1 7/8 XCE203612 45 9 5 3 1/2 150 31 15 1 1 3/8 XCE204806 65 13 5 3 1/2 150 43 15 1 1 7/8 XCE204812 65 13 5 3 1/2 150 43 15 1 1 3/8 XCE242408 36 6 6 3 1/2 150 19 19 1 1 1/2 XCE242410 36 6 6 3 1/2 150 19 19 1 1 1/2 XCE243008 42 7 6 3 1/2 150 25 19 1 1 7/8 XCE243608 54 9 6 3 1/2 150 31 19 1 1 7/8 XCE243610 54 9 6 3 1/2 150 31 19 1 1 7/8 XCE243612 54 9 6 3 1/2 150 31 19 1 1 3/8 XCE323612 72 9 8 3 1/2 150 31 27 1 1 3/8 5A–7 XCE Series Recommended Spacing For Operators In Covers Note: Closer spacing other than 3 & 31/2 inches available – Consult factory for special designs. 187 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 188 XCE & XJF Explosionproof Enclosures 5A–8 188 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 189 Conduit Drilling and Tapping Guidelines When drilling & tapping enclosures for conduit, proper installation requires compliance with the following: 1. Must be tapped with at least 5 full NPT threads (XCEX requires six NPT threads) in enclosure back or sides only; min. 1/2" conduit size. 2. Tapping depth of NPT holes must be plus 1/2 turn min. to plus 1-1/2 turns max. past standard NPT plug gage notch. 3. Inner end of conduit openings shall be smooth and well-rounded. TABLE I Thread Size Of Minimum wall thickness at conduit entrance excluding XCEX Conduit, Inches (NPT) Explosionproof 1/2 - 3/4 3/8 inch Dust Ignition Proof / Weather Proof 1/4 inch 1-2 7/16 inch 5/16 inch 2 1/2 - 5 5/8 inch 7/16 inch TABLE II Conduit size, inches (NPT) 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 5 Minimum Distance from conduit CL to inside corner or back of box 1 5/16 1 7/16 1 9/16 1 3/4 1 7/8 2 1/8 2 3/8 2 11/16 2 15/16 3 1/4 3 7/8 Approximate diameter of union 1 7/8 1 7/8 2 1/16 2 7/8 3 1/4 3 7/8 4 7/8 5 1/2 6 6 1/2 7 1/2 1 3/4 1/2 1 1/2 TABLE III Minimum spacing between conduit centers thru sidewalls only (inches) (Double all distances in table for holes located in backwall) 5 4 3 1/2 3 2 1/2 1/2 4 1/2 3 5/8 3 3/8 3 2 5/8 3/4 4 3/4 3 3/4 3 1/2 3 1/8 2 3/4 1 4 7/8 4 3 5/8 3 1/4 3 1 1/4 5 1/8 4 1/8 3 7/8 3 1/2 3 1/8 1 1/2 5 1/2 4 1/4 4 3 5/8 2 5 3/4 4 5/8 4 1/4 3 7/8 2 1/2 6 4 7/8 4 5/8 4 1/4 3 7/8 3 6 1/4 5 3/8 5 4 5/8 3 1/2 6 1/2 5 5/8 5 1/4 4 6 3/4 5 7/8 5 7 1/4 2 1 1/2 1 1/4 2 3/8 2 1 7/8 1 3/4 1 5/8 2 1/2 2 1/8 2 1 7/8 1 3/4 2 5/8 2 3/8 2 1/4 2 2 7/8 2 1/2 2 3/8 3 1/4 3 2 5/8 3 5/8 3 1/4 5A–9 Size This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and conditions under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Note: All dimensions are in inches. Metric threads available from factory for Group C & D applications only – Consult Factory. The Adalet engineering department is available to assist in designing custom explosionproof enclosures for your products. 189 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 190 Conduit & Auxiliary Device Drilling and Tapping Guidelines SPACING FOR AUXILIARY DEVICES INSTALLED IN BOX WALLS OF CONTROL PANEL ENCLOSURES USED IN HAZARDOUS LOCATIONS. When using an Auxiliary Device in the box wall of an enclosure used in hazardous locations, proper installation requires compliance with the following: 1. A minimum of (5) thread engagement, class 2 fit, required for group C & D applications. A minimum of (7) thread engagement, class 2 fit, required for group B applications. 2. Table I shows minimum box wall thickness for Auxiliary Device threads. TABLE I REQUIRED MINIMUM BOX WALL THICKNESS Thread Size (In.) 1/2 – 3/4 NPSM 1 NPSM Group C & D Applications min. (5) thread engagement Group B Applications min. (7) thread engagement Typical Auxiliary Devices XBO, XHPB, XHSS, Standard Operators (14 PITCH) (11 1/2 PITCH) 3/8 NPSM (18 PITCH) 3/8 – 16 UNC 3/8 Inch 1/2 Inch 7/16 Inch 5/8 Inch XCBH Large Handle Assembly 9/32 Inch 13/32 Inch XCBH Small Handle Assembly 5/16 Inch 7/16 Inch XMOB, XMOSS, Mini Operators 3. If Auxiliary Device contains undercut in engaging threaded section, the minimum wall thickness shown in Table I must increase to maintain the minimum required thread engagement. (Fig. A) 4. Table II provides the minimum distance an Auxiliary Device center can be placed from inside corner or back of box. SEE NOTE 3 TABLE II AUXILIARY DEVICE THREAD SIZE (In.) 3/8-16 UNC 3/8 NPSM 1/2 NPSM 3/4 NPSM 1 NPSM Minimum distance from Auxiliary Device CL to inside corner of back of box. 1-1/2 1-5/8 1-3/4 1-7/8 2 Auxiliary Device COUNTERSINK/ CHAMFER DEPTH WALL Y THICKNESS 5. Table III shows minimum spacing between conduit and Auxiliary Device entrances. FIG. A TABLE III Minimum space between centers of conduits and auxiliary devices in box wall. (Inches) Conduit Thread Size (NPT) 5 4 3-1/2 3 2-1/2 2 1-1/2 1-1/4 1 3/4 1/2 3/8 4-1/2 3-5/8 3-3/8 3 2-5/8 2-3/8 2 1-7/8 1-3/4 1-5/8 1-1/2 1/2 4-5/8 3-3/4 3-1/2 3-1/8 2-3/4 2-1/2 2-1/4 2-1/8 2 1-7/8 1-3/4 3/4 4-3/4 4 3-5/8 3-1/4 2-7/8 2-5/8 2-3/8 2-1/4 2-1/8 2 1-7/8 1 5 4-1/4 3-7/8 3-1/2 3 2-3/4 2-1/2 2-3/8 2-1/4 2-1/8 2 5A–10 Aux. Device Thread Size TABLE IV 6. Table IV shows minimum spacing between auxiliary device entrances. NOTE: Increase distance between devices as required to maintain minimum through air spacing of contacts required by electrical codes. 7. Double all distances in Table III and IV for holes located in back wall. Minimum spacing between Auxiliary Device of varying thread sizes (Inches) 3/8 1/2 3/4 1 3/8 1-1/2 1-1/2 1-1/2 2-1/2 1/2 1-1/2 2 2 2-1/2 3/4 1-1/2 2 2 3 1 2-1/2 2-1/2 3 3-1/2 Consult factory for layout data sheets. 190 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 191 XCE and XJF Mounting Pans and Hinges Catalog Number (Steel) XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM XSM 0416 0608 0611 0612 0613 0710 0718 0808 0810 0812 0911 1010 1012 1014 1212 1218 1220 1224 1230 1236 1246 1414 1422 1428 1616 1624 1628 1630 1634 1646 1818 1824 1830 1836 2036 2048 2424 2430 2436 3236 HINGES Catalog Number (Aluminum) Catalog Number (Phenolic) Pan Dimensions Nominal Width Length XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB XSB 3 5 5 5 5 6 6 0416 0608 0611 0612 0613 0710 0718 0808 0810 0812 0911 1010 1012 1014 1212 1218 1220 1224 1230 1236 1246 1414 1422 1428 1616 1624 1628 1630 1634 1646 1818 1824 1830 1836 2036 2048 2424 2430 2436 3236 0416 0608 0611 0612 0613 0710 0718 0808 0810 0812 0911 1010 1012 1014 1212 1218 1220 1224 1230 1236 1246 1414 1422 1428 1616 1624 1628 1630 1634 1646 1818 1824 1830 1836 2036 2048 2424 2430 2436 3236 1/4 1/8 1/8 1/8 1/8 1/8 1/8 7 7 6 7/8 8 8 7/8 10 7/8 8 7/8 10 7/8 10 1/2 11 11 10 3/4 10 3/4 10 3/4 12 7/8 12 7/8 12 7/8 14 3/4 14 1/2 26 1/2 14 1/2 32 1/2 14 1/2 16 3/4 16 1/2 16 1/2 16 1/2 34 1/2 46 1/2 22 22 34 29 Enclosure Size Reference Inside width x length 15 1/4 7 1/8 10 1/8 11 1/8 12 1/8 9 1/8 17 3/8 7 9 1/8 10 7/8 10 8 7/8 8 7/8 12 7/8 10 7/8 16 1/2 19 23 28 3/4 34 3/4 44 3/4 12 7/8 20 7/8 26 7/8 14 3/4 22 1/2 14 1/2 28 1/2 14 1/2 44 1/2 16 3/4 22 1/2 28 1/2 34 1/2 18 1/2 18 1/2 22 28 22 33 4 6 6 6 6 7 7 8 8 8 9 10 10 10 12 12 12 12 12 12 12 14 14 14 16 16 16 16 16 16 18 18 18 18 20 20 24 24 24 32 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 16 8 11 12 13 10 18 8 10 12 11 10 12 14 12 18 20 24 30 36 46 14 22 28 16 24 28 30 34 46 18 24 30 36 36 48 24 30 36 36 Weight Each (pounds) (Steel) Hinges Catalog Number 1 1/2 1 1 1/2 1 3/4 2 1 1/4 2 1/2 1 1/4 1 1/2 2 1/4 2 1/2 2 1/2 3 3 1/2 3 3/4 5 1/2 6 1/2 8 9 3/4 11 3/4 15 5 8 10 3/4 6 3/4 10 1/4 12 12 1/2 14 3/4 20 1/4 8 3/4 11 1/2 14 3/4 18 20 27 15 1/4 19 1/4 23 1/2 28 3/4 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHB-2 XHC-2 XHC-2 XHC-2 XHC-2 XHC-2 XHD-3 4 6 6 6 6 7 7 8 8 8 9 10 10 10 12 12 12 12 12 12 x 16 x8 x 11 x 12 x 13 x 10 x 18 x8 x10 x 12 x 11 x 10 x 12 x 14 x 12 x 18 x 20 x 24 x 30 x 36 XHD-4 XHC-2 XHF-2 XHF-2 XHD-2 XHF-2 XHF-2 XHF-2 XHD-3 XHF-4 XHF-2 XHF-2 XHF-2 XHF-3 XHF-3 XHF-4 XHF-2 XHF-2 XHF-3 XHF-3 12 14 14 14 16 16 16 16 16 16 18 18 18 18 20 20 24 24 24 32 x x x x x x x x x x x x x x x x x x x x Mounting Pans MATERIAL — Steel: (XSM) Galvanized 12 gauge steel plate. The catalog number includes the steel mounting pan complete with 1/4" high spacers and stainless steel mounting screws. MATERIAL — Aluminum: (XSA) Consult factory for availability. MATERIAL — Phenolic: (XSB) A special phenolic laminated material that has high mechanical and dielectric strength. It is excellent for mounting and wiring control equipment. The catalog number includes the phenolic board, 3/8" thick, complete with 1/4" high spacers and stainless steel mounting screws. Enclosure Size Reference Inside width x length 46 14 22 28 16 24 28 30 34 46 18 24 30 36 36 48 24 30 36 36 5A–11 MOUNTING PANS Hinge Set Description: Made of extruded aluminum alloy consisting of two sections, female and male (with stainless steel pin) and four stainless steel hex head bolts. Designed to allow right or left hand removable or non-removable installation. Unless specified, left hand removable hinge installation will be furnished by factory when hinged enclosures are ordered. Note: Catalog numbers represent complete hinge sets necessary for enclosure assembly. Note: No installation charge when customer specifies factory installation of mounting pan. 191 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 192 XCE Glass Windows DIVISION I AND DIVISION II CLASS I GROUPS B, C, & D; CLASS II GROUPS E, F, & G NEMA 7, 9, NEMA 4/IP66 (OPTIONAL) Circular Window Window Viewing Area Diameter Overall Window Cover Diameter Minimum Enclosure Inside Width / Length XGC 10 1 1/8 3 8 XGC 20 1 15/16 4 1/8 9 XGC 30 3 5 3/16 9 XGC 40 4 6 3/8 9 XGC 52 5 1/4 7 7/8 12 XGC 66 6 11/16 10 3/8 16 XGC 80 8 12 1/8 18 All dimensions are in inches. Glass window catalog number includes XCE cover machining and installation. For raintight, watertight NEMA 4/IP66 option add suffix “N4”. To order glass windows for field installations, add suffix SLF to XGC catalog no. Consult factory for closer spacing requirements, multiple windows or combinations of operators and windows. 5A–12 Rectangular Window Window Viewing Area Size Minimum Enclosure Inside Width Minimum Enclosure Inside Length XGW 0303 3X3 8 8 XGW 0305 3X5 8 10 XGW 0307 3X7 8 12 XGW 0505 5X5 10 10 XGW 0509 5X9 10 14 XGW 0707 7X7 12 12 XGW 0713 7 X 13 12 18 XGW 0909 9X9 14 14 XGW 1111 11 X 11 16 16 XGW 1313 13 X 13 18 18 All dimensions are in inches. Glass window catalog number includes installation. For raintight, watertight NEMA 4 option add suffix “N4”. Consult factory for special viewing area requirement, closer spacing and to combine windows with other window sizes or operators. 192 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 193 DJF and WJF External Flanged Junction Boxes DJF DUST-TIGHT EXTERNAL FLANGED JUNCTION BOXES CLASS II GROUPS E, F, & G; NEMA 9 DJF/WJF Catalog Number Inside Nominal Dimensions W L D Mounting Bolt Size Side Wall Thickness Shipping Weight, Pounds 061105 6 11 5 8 3/8 13 1/8 6 13/16 7 1/2 8 5/8 3/8 3/8 16 061305 6 13 5 8 1/8 15 1/8 6 13/16 9 1/2 8 5/8 3/8 3/8 18 071805 7 18 5 9 1/8 20 1/8 6 13/16 14 1/2 9 1/8 3/8 3/8 30 121806 12 18 6 14 1/2 20 1/2 7 15/16 14 3/8 14 3/4 1/2 7/16 42 122005 12 20 5 14 1/4 22 1/4 6 15/16 14 3/8 14 3/4 1/2 7/16 47 122406 12 24 6 141/4 26 1/4 7 15/16 18 3/4 14 3/4 1/2 7/16 52 122408 12 24 8 14 1/4 26 1/4 9 15/16 18 3/4 14 3/4 1/2 7/16 62 123006 12 30 6 14 3/8 32 3/8 8 1/16 22 3/4 15 5/8 1/2 67 123208 12 32 8 15 35 10 3/16 27 1/2 14 1/8 1/2 5/8 80 123608 12 36 8 14 3/8 38 3/8 10 3/16 29 14 3/4 1/2 5/8 110 Overall Dimensions A B C Mounting Lug CL to CL E F 5A–13 WJF WATERTIGHT EXTERNAL FLANGED JUNCTION BOXES NEMA 4 193 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 A 12/9/01 11:03 AM Page 194 DJF and WJF External Flanged Junction Boxes 5A–14 194 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 195 XIF/XIFC Explosionproof Internal Flanged Junction Boxes & Control Enclosures XIF: Junction Boxes XIFC: Control Enclosures Optional NEMA 4. Add suffix “N4” to catalog number. Use layout sheet for drilling and tapping specifications. XIFC Certifications: (N4 Optional) • Class I, Groups C & D • Class II, Groups E, F & G • Class III • UL 1203 (Classified) Inside Nominal Catalog Number Mounting Lug Dimensions Overall Dimensions CL to CL Mounting Shipping Bolt Weight, W L D A B C E F Size Pounds 4 5/16 3 1/4 5 1/2 5/16 5 XIFC 030303 XIF 030303 3 5/16 3 5/16 3 3/16 4 1/2 4 1/2 XIFC 030603 XIF 030603 3 1/4 5 3/4 3 4 1/2 7 1/16 4 1/4 3 1/4 8 5/16 6 1/2 XIFC 030703 XIF 030703 3 1/4 6 7/8 3 4 1/2 8 1/8 4 5/16 3 5/16 9 5/16 7 1/2 XIFC 030903 XIF 030903 3 4 1/2 10 1/16 4 5/16 3 1/4 11 5/16 9 1/2 XIFC 031103 XIF 031103 3 1/4 10 15/16 3 4 1/2 12 4 5/16 3 1/4 13 5/16 11 XIFC 031303 XIF 031303 3 1/4 12 13/16 3 4 1/2 14 1/16 4 5/16 3 1/4 15 5/16 11 1/2 XIFC 031503 XIF 031503 3 1/4 14 3/4 3 1/16 4 1/2 16 4 5/16 3 1/4 17 5/16 13 XIFC 031803 XIF 031803 3 1/4 17 3/4 3 4 1/2 19 4 1/4 3 1/4 20 5/16 16 XIFC 032403 XIF 032403 3 1/4 23 9/16 3 4 1/2 25 1/16 4 5/16 3 1/4 26 5/16 21 XIFC 033003 XIF 033003 3 1/4 29 1/2 3 4 9/16 31 1/16 4 5/16 3 1/4 32 1/8 5/16 28 XIFC 033603 XIF 033603 3 1/4 35 7/16 3 4 1/2 37 4 3/8 3 1/4 38 1/8 5/16 33 XIFC 040604 XIF 040604 4 1/8 5 7/8 4 5 3/8 7 5 5/16 4 3/8 8 1/4 5/16 8 1/2 XIFC 041204 XIF 041204 4 1/4 11 13/16 4 5 1/2 13 1/8 5 5/16 4 3/8 14 1/4 5/16 15 1/2 XIFC 060606 XIF 060606 5 1/2 5 1/2 6 7 7 7 3/8 5 1/2 8 1/2 3/8 14 XIFC 060608 XIF 060608 5 1/4 5 1/2 8 7 7 9 3/8 5 1/2 8 1/2 3/8 17 1/2 XIFC 061206 XIF 061206 5 1/4 11 1/8 6 7 1/4 13 1/2 7 5/8 5 1/2 15 3/8 28 XIF 061806 6 18 6 7 1/2 19 1/2 7 13/16 5 1/2 21 1/8 3/8 33 XIF 062406 6 24 6 7 1/2 25 1/2 7 3/4 5 1/2 27 3/8 59 XIF 063606 6 36 6 7 1/2 37 1/2 7 13/16 5 1/2 39 3/8 84 XIF 070704 6 7/8 6 7/8 4 5 5/16 6 5/8 9 1/8 3/8 13 XIF 071603 7 16 3 1/2 8 1/2 17 1/2 5 5/16 6 1/2 18 7/8 3/8 36 XIF 083206 8 32 5 7/8 9 1/2 33 1/2 7 7/8 7 1/2 35 3/8 87 XIFC 070704 3 11/32 8 15/16 7 15/16 7 15/16 5B–1 XIF Compliances: • NEC Class I, Group D • Class II, Groups E, F & G • Class III • UL Standard 886 • CSA Standard C22.2 No. 30 • For XIF consult factory for specific certifications. Note: All dimensions are in inches and are nominal enclosure size only. 195 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 196 XIF/XIFC Explosionproof Internal Flanged Junction Boxes & Control Enclosures CAT. # XIF(C)________ 5B–2 196 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 197 XIF/XIFC Mounting Pans MATERIAL — Steel: (XSM) Galvanized 12 gauge steel plate. The catalog number includes the steel mounting pan complete with 1/4" high spacers and stainless steel mounting screws. MATERIAL — Aluminum: (XSA) Consult factory for availability. MATERIAL — Phenolic: (XSB) A special phenolic laminated material that has high mechanical and dielectric strength. It is excellent for mounting and wiring control equipment. The catalog number includes the phenolic board, 3/8" thick, complete with 1/4" high spacers and stainless steel mounting screws. Note: No installation charge when customer specifies factory installation of mounting pan. Catalog Number (Aluminum) Catalog Number (Phenolic) Pan Dimensions Width Length Enclosure Size Reference Inside Width x Length Weight Each (pounds) (Steel) XSM 0303 XSA 0303 XSB 0303 3 3 3x3 1/4 XSM 0306 XSA 0306 XSB 0306 3 5 1/2 3x6 1/2 XSM 0307 XSA 0307 XSB 0307 3 6 1/2 3x7 1/2 XSM 0309 XSA 0309 XSB 0309 3 8 1/2 3x9 3/4 XSM 0311 XSA 0311 XSB 0311 3 10 1/2 3 x 11 1 XSM 0313 XSA 0313 XSB 0313 3 12 1/2 3 x 13 1 1/4 XSM 0315 XSA 0315 XSB 0315 3 14 1/2 3 x 15 1 1/2 XSM 0318 XSA 0318 XSB 0318 3 17 1/2 3 x 18 1 3/4 XSM 0324 XSA 0324 XSB 0324 3 23 1/2 3 x 24 2 1/4 XSM 0330 XSA 0330 XSB 0330 3 29 3 x 30 2 3/4 XSM 0336 XSA 0336 XSB 0336 3 35 3 x 36 3 1/4 XSM 0406 XSA 0406 XSB 0406 3 7/8 5 1/2 4x6 3/4 XSM 0412 XSA 0412 XSB 0412 3 7/8 11 1/2 4 x 12 1 1/2 XSM 0606 XSA 0606 XSB 0606 51/2 51/2 6x6 1 XSM 0612 XSA 0612 XSB 0612 5 1/2 11 1/2 6 x 12 2 XSM 0618 XSA 0618 XSB 0618 5 5/8 16 7/8 6 x 18 3 XSM 0624 XSA 0624 XSB 0624 5 5/8 22 7/8 6 x 24 4 XSM 0636 XSA 0636 XSB 0636 5 5/8 34 7/8 6 x 36 6 XSM 0707 XSA 0707 XSB 0707 6 1/2 6 1/2 7x7 1 1/2 XSM 0716 XSA 0716 XSB 0716 6 1/2 15 1/2 7 x 16 3 XSM 0832 XSA 0832 XSB 0832 7 1/2 31 1/2 8 x 32 7 1/2 5B–3 Catalog Number (Steel) When ordering separately, be sure to designate that mounting pan is for XIF series enclosure and specify size of box. 197 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 198 DIF and WIF Junction Boxes DIF DUST-TIGHT INTERNAL FLANGED JUNCTION BOXES CLASS II GROUPS E, F, & G; NEMA 9 WIF WATERTIGHT INTERNAL FLANGED JUNCTION BOXES NEMA 3, 4 5B–4 DIF/WIF Catalog Number Inside Nominal Dimensions W L D Mounting Bolt Size Side Wall Thickness Shipping Weight, Pounds 101406 10 14 6 10 3/4 14 3/4 7 5/16 12 3/8 10 3/4 3/8 3/8 28 164810 16 48 10 17 49 11 5/8 19 41 1/16 5/8 1/2 150 202408 20 24 8 21 25 9 9/16 22 3/8 17 1/2 1/2 1/2 90 202412 20 24 12 21 25 13 9/16 22 1/2 17 1/2 1/2 1/2 106 243608 24 36 8 25 37 9 5/8 27 1/4 28 5/8 1/2 146 364808 36 48 8 37 49 9 3/8 39 1/4 41 5/8 1/2 242 242414 24 24 14 25 25 15 9/16 26 1/2 17 1/2 1/2 1/2 120 Overall Dimensions A B C Mounting Lug CL to CL E F Note: WIF Series includes a one piece neoprene gasket. Mounting lugs optional. DIF Series does not include mounting lugs or gasket. 198 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 199 XHFA Explosionproof Fire Alarm Stations CLASS I, GROUPS B*, C, & D; CLASS II, GROUPS E, F & G, NEMA 4, 7 & 9 Fire alarm call stations, for installation in hazardous atmosphere locations where emergency control of fire alarm or signal circuits is required. Station is painted red for easy identification. Housing and break glass hammer are cast aluminum alloy. Exposed operator parts are red anodized aluminum. A yellow adhesive backed label “Caution-Stand Clear of Area in Front of Glass to Protect Eyes from Flying Glass”, furnished for application above the alarm station. Complete Assembly Catalog Number with 3/4” NPT conduit opening top and bottom Catalog Number with 1” NPT conduit opening top and bottom XHFA 31-N4 XHFA 41-N4 XHFA 32-N4 XHFA 33-N4 XHFA 42-N4 XHFA 43-N4 Replacement glass: Catalog number XHFG * Add GB suffix to part number for group B. Example: XHFA 31-GB-N4. 5C–1 Important Notice: Contacts are shown as held in their actuated position. Note: Contact blocks furnished as standard. Compliances: Maximum current ratings for control circuit contacts NEC Class I, Group B*, C and D Class II, Groups E, F & G UL Standard 886 • UL Standard 689 UL Standard UL38 manually actuated signaling boxes for use with Fire Protective Signaling Systems. Aluminum Alloy Copper Content 0.3% max. Volts Make Amperes Break Amperes Continuous Carrying 120 240 60 30 6 3 10 10 199 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 200 Junction Boxes General Purpose, Weatherproof NEMA TYPE 1, NEMA TYPE 4 (OPTIONAL) JP (UNFLANGED TYPE FOR SURFACE MOUNTING) JF (FLANGED TYPE FOR SURFACE MOUNTING) JR (RECESSED COVER TYPE FOR FLUSH MOUNTING) JH (HINGED COVER TYPE FOR SURFACE MOUNTING) JU (ABOVE GROUND TYPE FOR CONDUIT MOUNTING) APPLICATIONS: Designed for installation in electrical systems requiring rugged applications. • Wiring: pull boxes, splices, taps and terminal strips. • Housing for apparatus, instruments, terminal strips and other equipment. FEATURES: • Rugged sand-cast copper-free aluminum alloy, 0.3% maximum copper content. • Tumblasted for quality appearance. • Boxes are furnished complete with cover, neoprene gasket and stainless steel cover bolts, except “JU Series” enclosures, which are furnished with steel zinc dichromate plated cover bolts. • Grounding screw standard. OPTIONS: • Cast-on mounting buttons, bosses and pads available for terminal block or equipment mounting. • Conduit openings available, drilled and tapped or drilled slip fit for type 1 applications, to customer requirements. • NEMA type 4, standard on JR Series when used for direct burial in concrete or cinder fill, JF, JP and JH require addition of mounting lugs, cast on long side unless otherwise specified. Wall thickness must be 5/16” or greater for conduit sizes up to 2” NPT to permit, not less than 3-1/2 threads of engagement. Enclosures with less than 5/16” wall thickness require padded conduit entrances to maintain 3-1/2 thread engagement. 5D–1 Compliances CSA STANDARD C22.2 NO. 18 UL STANDARD 50 CONTACT FACTORY FOR SPECIFIC UL, CSA, FILE NUMBERS 200 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 201 Junction Boxes General Purpose, Weatherproof W Nominal Inside Dimensions (Inches) L D Wall Thick. Inches Ship. Wt. Lbs. Catalog Number W Nominal Inside Dimensions (Inches) L D Wall Thick. Inches Ship. Wt. Lbs. 2-3/4 4-1/4 1-3/16 1/8 1 JP 121204 12 12 JP 030302 3-1/2 3-1/2 2-1/8 1/8 1 JP 121206 12 12 4 5/16 17 6 5/16 JP 030303 3-9/16 3-9/16 2-7/16 5/16 2 JP 121208 12 21 12 8 5/16 JP 040403 4 4 2-1/2 5/32 1-1/2 JP 121604 24 12 16 4 5/16 JP 040404 4 4 4 1/4 3 17 JP 121606 12 16 6 5/16 JP 040603 4 6 2-1/2 1/4 21 3 JP 121608 12 16 8 5/16 JP 040604 4 6 4 26 7/32 4 JP 121806 12 18 6 5/16 JP 040804 4 8 26 4 5/16 6 JP 121810 12 18 10 5/16 JP 041204 4 36 12 4 5/16 8 JP 122406 12 24 6 5/16 38 JP 060603 JP 060604 6 6 3-1/2 5/16 6 JP 122408 12 24 8 5/16 48 6 6 4 5/16 6 JP 123606 12-1/8 36-1/2 6 1/2 82 JP 060606 6 6 6 5/16 7 JP 141406 14 14 6 5/16 25 JP 060804 6 8 4 5/16 7 JP 151508 15 15 8 3/8 32 JP 060806 6 8 6 5/16 10 JP 181806 18 18 6 5/16 57 JP 061004 6 10 4 5/16 9 JP 181808 18 18 8 5/16 48 JP 061204 6 12 4 5/16 10 JP 181810 18 18 10 5/16 53 JP 061206 6 12 6 5/16 11 JP 181812 18 18 12 5/16 63 JP 080804 8 8 4 5/16 9 JP 182408 18 24 8 3/8 65 JP 080806 8 8 6 5/16 11 JP 183606 18 36 6 1/2 94 JP 080808 8 8 8 5/16 12 JP 183608 18 36 8 1/2 126 JP 081004 8 10 4 5/16 9 JP 242408 24 24 8 3/8 80 JP 081006 8 10 6 5/16 13 JP 242410 24 24 10 5/16 92 JP 081008 8 10 8 5/16 15 JP 243008 23-3/4 23-3/4 8 3/8 94 JP 081204 8 12 4 5/16 11 JP 243606 24 36 6 1/2 114 JP 081206 8 12 6 5/16 16 JP 243608 24-1/8 36-1/8 8 3/8 113 JP 101204 10 12 4 5/16 12 JP 243612 24 36 12 1/2 173 JP 101206 10 12 6 5/16 18 JP 363612 36 36 12 1/2 226 JP 101208 10 12 8 5/16 21 Catalog Number JP 020401 5D–2 UNFLANGED TYPE FOR SURFACE MOUNTING CSA Certified LR28852 UL Listed E33075 201 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 202 Junction Boxes General Purpose, Weatherproof FLANGED TYPE FOR SURFACE MOUNTING W Nominal Inside Dimensions (Inches) L 6 6 JF 060606 6 6 JF 060804 6 8 JF 060806 6 8 6 1/4 9 JF 061206 6 11-13/16 6 1/4 11 Catalog Number JF 060604 D Wall Thick. Inches Ship. Wt. Lbs. 4 1/4 5-1/2 6 1/4 8 4 7/32 6 JF 080804 8 8 4 3/8 11 JF 080806 8 8 6 3/8 13-1/2 JF 081206 8 12 6 5/16 14-1/2 JF 121206 12 12 6 1/4 17 JF 121208 12 12 8 1/4 20 JF 121810 12 18 10 5/16 47 JF 122406 12 24 6 3/8 35 JF 122408 12 24 8 7/16 62 JF 183608 18 36 8 1/2 157 CSA Certified LR28852 UL Listed E33075 RECESSED COVER TYPE FOR FLUSH MOUNTING W Nominal Inside Dimensions (Inches) L 5D–3 D Wall Thick. Inches Ship. Wt. Lbs. 4 4 JR 040604 4 6 4 1/4 5 4 1/4 JR 060604 6 6 6 4 1/4 5-1/2 JR 060606 JR 060804 6 6 6 1/4 8 6 8 4 1/4 6 JR 060806 6 8 6 1/4 9 JR 061006 6 10 6 1/4 12 JR 061206 6 12 6 1/4 14 JR 080804 8 8 4 3/8 12 JR 080806 8 8 6 3/8 14 JR 080808 8 8 8 3/8 18 JR 081206 8 12 6 5/16 15 JR 101006 10 10 6 1/4 18 JR 121206 12 12 6 1/4 19 JR 121208 12 12 7-15/16 1/4 20 JR 121810 12 18 10 5/16 48 Catalog Number JR 040404 JR 122406 12 24 6 3/8 36 CSA Certified LR28852 JR 161606 16-1/4 16-1/4 6 5/16 34 UL Listed E33075 JR 161808 16 18 8 3/8 44 50 JR 161810 16 18 10 3/8 JR 181812 18-3/16 18-3/16 12-5/32 5/16 66 JR 183608 18 36 8 1/2 150 All JR style weatherproof cast aluminum junction boxes are coated with a black asphalt paint - for direct burial in concrete or cinder fill and are UL approved for this application. Covers are plain with no coating. Covers have rubber stamped marking “Suitable for use in concrete or cinder fill”. 202 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 BCD 12/9/01 11:05 AM Page 203 Junction Boxes General Purpose, Weatherproof HINGED COVER TYPE FOR SURFACE MOUNTING Catalog Number W Nominal Inside Dimensions (Inches) L D Wall Thick. Inches Ship. Wt. Lbs. 6 With 2 Hinges and 1 Wing Bolt JH 060604 6 6 4 1/4 JH 060606 6 6 6 1/4 8 JH 060804 5-15/16 8 4 1/4 8 5-15/16 8 6 1/4 9 JH 060806 With 2 Hinges and 2 Wing Bolts JH 061004 5-15/16 10 4 1/4 10 JH 061204 5-15/16 11-7/8 3-15/16 1/4 10-1/2 JH 061206 5-15/16 11-7/8 6 1/4 13-1/2 JH 080804 8 8 4 1/4 9-1/2 JH 080806 8 8 6 1/4 11-1/2 JH 080808 8 8 8 1/4 13 JH 081004 8 10 4 1/4 11 JH 081006 8 10 6 1/4 12 JH 081008 8 10 8 1/4 14 JH 081204 8 12 4 1/4 12 JH 081206 8 12 6 1/4 14-1/2 CSA Certified LR28852 UL Listed E33075 With 2 Hinges and 4 Wing Bolts Catalog Number W Nominal Inside Dimensions (Inches) L D Wall Thick. Inches Ship. Wt. Lbs. JH 101204 10 12 4 1/4 15 JH 101206 10 12 6 1/4 17 JH 121604 12 16 4 1/4 21 JH 101208 10 12 8 1/4 19 JH 121606 12 16 6 1/4 23 JH 121204 12 12 4 1/4 17-1/2 JH 121608 12 16 8 1/4 29 JH 121206 12 12 6 1/4 21-1/2 JH 141406 14-1/8 14-1/8 6-1/6 1/4 21 JH 121208 12 12 8 1/4 24-1/2 JH 151508 15 15 8 1/4 40 With 2 Hinges and 4 Wing Bolts With 3 Hinges and 5 Wing Bolts JH 121806 12 18 6 1/4 26-1/2 JH 121810 12 18 10 1/4 46-1/2 JH 122406 12 24 6 5/16 37 JH 122408 12 24 8 5/16 47 JH 123606 12-1/8 36-1/2 6-1/16 1/2 78 18 18 6 5/16 52 JH 181808 18 18 8 5/16 50 JH 181810 18 18 10 5/16 54 JH 181812 18 18 12 5/16 75 JH 182408 18 24 8 3/8 89 JH 183606 18 36 6-1/16 1/2 103 138 JH 183608 18 36 8 1/2 JH 242408 24 24 8 3/8 77 JH 243008 24 30 8 3/8 116 JH243606 24 36 6-1/16 1/2 128 JH 243608 24 36 8 1/2 136 JH 243612 24 36 12 1/2 165 203 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 5D–4 With 3 Hinges and 7 Wing Bolts JH 181806 15599 Sec.5 E 12/9/01 11:06 AM Page 204 Junction Boxes Explosionproof JUNCTION BOXES THREADED FLAT COVER STYLE EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 3, 7 & 9, Raintight Junction Boxes for Service Station Islands XSO 885 is a larger cast aluminum raintight explosionproof box having inside dimensions of 8” x 8” x 5” deep. Standard blank, drilled and tapped to specification. Any of the XVS “sealing” hubs can be installed in the back. Catalog Number Nominal Inside Dimensions (In.) Shipping Weight Lbs. XSO 885 8 x 8 x 5 deep 20 91⁄8" 91⁄8" XVS VERTICAL SEALING HUBS 7 69⁄16" Vertical sealing hubs save space and are accessible from the inside of the box for packing and sealing. Size, number and location of seals must be specified in the order. They must be factory installed and must be added to the price of the box. Catalog number and price include installation in the box. The male thread is not a standard pipe thread. UL & CSA approval of XSO 884 & XSO 885 is maintained with use of XVS hub. 5E–1 Catalog Number Conduit Size A B Dimensions (Inches) C D XVS4 1” 2-1/16 1-3/4 XVS5 1-1/4” 2-1/2 2-1/8 2 1-1/4 11/16 XVS6 1-1/2” 2-3/4 2-3/8 2-1/4 1-9/16 11/16 XVS8 2” 3-3/16 2-7/8 2-3/4 2 11/16 1-5/8 7/8 E 11/16 NOTE: Sealing hubs for use only with Adalet XSC sealing compound. CSA Certified LR27991 UL Listed E10493 204 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:06 AM Page 205 Junction Boxes Explosionproof JUNCTION BOXES THREADED FLAT COVER STYLE EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 3, 7 & 9, Raintight Junction Boxes for Service Station Islands These three sizes of flush mounting service station island junction boxes should answer all requirements for station island loads. The side walls are cast blank and are drilled and tapped to requirements. The wall sections are heavy enough for 2” conduit. They are all made raintight by Buna-N O-ring seals, having excellent resistance to petroleum oils and aromatic hydrocarbons. XSO 663B, box, having inside dimensions of 6” x 6” x 3” deep has 2-1” “sealing” hubs cast integrally in the back of the box, one plugged. The side walls are drilled and tapped to specification. 5 3⁄8" XSO 663S is the same box as XSO 663B but is a stock box drilled and tapped for three 3/4” conduits on each of two opposite sides, also has the 2-1” sealing conduit hubs, one plugged. XSO 884, a larger 8” x 8” x 4” deep cast aluminum raintight explosionproof box is completely flexible in that any size and number of sealing hubs, type XVS shown on page 5E–1, can be installed in the back, and conduit holes can be drilled and tapped in any or all side walls from 1/2” through 2”. Stocked blank, drilled and tapped to layout. 5E–2 XSO 884S is the same box as XSO 884 but is stocked, drilled and tapped, to handle most island requirements, consisting of one 1-1/4” “sealing conduit hub” in the back, and with three 3/4” drilled and tapped conduit holes on each of two opposite sides. Number & Size of Conduit Catalog Number Nominal Inside Dimension (In.) Each Side XSO 663S 6 x 6 x 3 deep None XSO 663B 6 x 6 x 3 deep XSO 884 8 x 8 x 4 deep XSO 884S 8 x 8 x 4 deep Top Bottom Back Sealing 3-3/4” 3-3/4” 2-1” Shipping Wt. Lbs. D & T to specifications thru 2” D & T to specifications thru 2” None 3-3/4” 3-3/4” 8 8-1/4 18 1-11/4” 18 NOTE: Sealing hubs for use only with Adalet XSC sealing compound. CSA Certified LR27991 UL Listed E10493 205 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:06 AM Page 206 Explosionproof and Dust-Tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUP D; CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9 MULTI-HUB GENERAL PURPOSE BOXES X82C/X83C Designed for general wiring in hazardous locations. For pulling and splicing conductors. X82 box has six 1/2” conduit entrances in the sides and two 3/4” conduit entrances in the back. X83 box has six 3/4” conduit entrances in the sides and two 3/4” conduit entrances in back. Boxes are furnished with close-up plugs as shown in chart. X82/X83 Catalog Conduit Left/Right Number Size Sides Top Number of Hubs Bottom Back Qty Wt. Lbs. X82* 1/2” One 1/2” Two 1/2” Two 1/2” Two 3/4” 10 19 And Plugged Open One Both Plugged Plugged 10 19 10 24 3/4” X83* X643C X643* 3/4” One 3/4” Two 3/4” Two 3/4” Two 3/4” Plugged Open One Both Plugged Plugged 3/4” One 3/4” One 3/4” Two 1” And Open Open, Open 1” Std. Package One Boss One Boss Undrilled Undrilled COVERS ONLY (CONSULT FACTORY FOR APPROVALS) X643 Catalog Standard Package Number Quantity Weight Lbs. 4 X82C Blank 10 X83C Blank 10 4 X643C Blank 10 4 Dome 1 1 XDC 5E–3 X8230 O-Ring for NEMA 4 watertight To order box with Dome Cover add XDC as suffix to catalog number required. XDC * * CSA Certified LR27991 UL Listed E10493 Compliance NEC Class I, Group D Class II, Groups E, F, G - Class III UL Standard 886 - CSA Standard C22.2 No. 30 206 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:06 AM Page 207 Explosionproof and Dust-Tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUP D; CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9 MULTI-HUB GENERAL PURPOSE BOXES Designed for general wiring in hazardous locations. For pulling and splicing conductors, also serves as fixture mounting outlets with appropriate cover. Boxes have 4 conduit entrances and are furnished with 2 close-up plugs. Catalog Number Conduit Size (In.) Standard Pkg. Quantity Standard Pkg. Weight Lbs. XJBCC2* 1/2 XJBCC3* 3/4 Blank 10 26 Cover 10 26 XJFCC2 1/2 XJFCC3 3/4 1/2” Stem 10 26 Cover 10 26 XJFC3C2 XJFC3C3 1/2 3/4” Stem 10 26 3/4 Cover 10 26 COVERS ONLY XJBC Blank 10 4 XJFC2 1/2” Stem 10 4 XJFC3 3/4” Stem 10 4 Nominal Dimensions (Inch) A XJBC & XJFC B 1/2 2-1/2 1-13/16 3/4 2-1/2 1-13/16 5E–4 Conduit Size Mounting hole size 5/16” * * CSA Certified LR27991 UL Listed E10493 Compliance NEC Class I, Group D Class II, Groups E, F, G - Class III UL Standard 886 - CSA Standard C22.2 No. 30 207 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:06 AM Page 208 Explosionproof and Dust-Tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUP C AND D; CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9 THERMOCOUPLE HEAD BOX XJAY Junction Box for thermocouple sensing heads. Body has 1/2” NPT entrance for probe unit and one 3/4” NPT conduit entrance with conduit stop. The body has an exterior pad 5/8” wide across the back between the conduit hubs. The interior of the box can be blind tapped into the back pad with screw spacing up to 2-3/4” for mounting terminal strips or connection blocks. The outside boss on the 1/2” hub and the interior boss on the cover can be blind tapped for screws for use with a retaining chain at additional cost. Consult factory. XJAY Catalog Number Conduit Size Standard Pkg. Quantity Standard Pkg. Weight Lbs. XJAY 1/2”-3/4” (1) EA. 10 10 XJAO O-Ring for NEMA 4 watertight XJAYRC Cover retaining chain 5E–5 Compliance NEC Class I, Groups C, D Class II, Groups E, F, G - Class III UL Standard 886 - CSA Standard C22.2 No. 30 208 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:07 AM Page 209 Explosionproof and Dust-Tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUP D; CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9 MULTI-HUB GENERAL PURPOSE BOXES Designed for general wiring in hazardous locations. For pulling and splicing conductors. XJLB Number of Hubs Std. Package Catalog Conduit Number Size Each Side Top Bottom Back Qty Wt. Lbs. XJLB2* 1/2” None None 1-1/2” 1-1/2” 10 10 XJLB3 3/4” None None 1-3/4” 1-3/4” 10 10 XJTB2* 1/2” 1 - 1/2” None 1-1/2” 1-1/2” 10 9 COVERS ONLY (CONSULT FACTORY FOR APPROVALS) XJU23 Blank Cover 10 3 XJUDC Dome Cover 10 8 To order box with Dome Cover add XJUDC as suffix to catalog number required. * * CSA Certified LR27991 UL Listed E10493 5E–6 XJTB XJUDC 209 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:07 AM Page 210 Explosionproof and Dust-Tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUP D; CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9 MULTI-HUB GENERAL PURPOSE BOXES Designed for general wiring in hazardous locations. For pulling and splicing conductors, these boxes also serve as fixture mounting outlets with appropriate cover. Boxes have 4 conduit entrances and furnished with 2 close-up plugs. XJULB has 5 conduit entrances and furnished with 3 plugs. Box Mounting hole size 5/16”. Nominal Dimensions (Inch) XJULB XJUC Catalog Number Conduit Size Cover Style Standard Pkg. Quantity Standard Pkg. Weight Lbs. XJUC2* 1/2 Blank 10 11-1/2 XJUC3* 3/4 Blank 10 11-1/2 XJULB2 1/2 Blank 10 11-1/2 XJULB3 3/4 Blank 10 11-1/2 COVERS ONLY (CONSULT FACTORY FOR APPROVAL) XJU23 Blank Cover 10 3 XJUDC Dome Cover 10 8 To order box with Dome Cover add XJUDC as suffix to catalog number required. * * XJUDC CSA Certified LR27991 UL Listed E10493 5E–7 210 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.5 E 12/9/01 11:07 AM Page 211 Explosionproof and Dust-Tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT CONTROL STATIONS FOR PANEL MOUNTING CLASS I, GROUPS C & D; CLASS II, GROUPS E, F, & G; NEMA 7 & NEMA 9 This group of station boxes and devices is designed for mounting on panel boards so that pilot lights, pushbuttons and switch handles are flush with panel fronts and the bodies or housings are in back of the panel. Threaded necks are provided with locknuts to clamp fittings in place on panels. The parts extending beyond the face of the panel have a black anodized finish. XB1 XB2 Station boxes are available in two styles. Economical style XA single station is suitable for 600 volt maximum use. XA bodies have threaded covers and are provided with 4 tapped hubs and 3 plugs. Style XB is suitable for combinations of pilot lights, pushbuttons and selector switches for 600 volt maximum use and are large enough to include pilot light transformers. XB bodies have flat machined joint covers fastened with machine screws. Covers give maximum accessibility to interiors. Catalog Number Description XA 2 1 station with four 1/2" tapped openings, three plugs XB3 XB4 W Outside Dim. L D 3 3/8 O.D. – 2 5/16 – 2 5/16 Weight Ea. Pounds 1 XA 3 1 station with four 3/4" tapped openings, three plugs 3 3/8 O.D. XB 1 1 station box – specify hubs 3 1/2 4 7/16 3 7/16 XB 2 2 station box – specify hubs 3 1/2 6 3/8 XB 3 3 station box – specify hubs 3 1/2 8 1/16 3 7/16 2 3/4 XB4 4 station box – specify hubs 3 1/2 9 5/8 3 1/4 1 1 3/4 3 7/16 3 7/16 2 Compliances: NEC Class I, Groups C & D (XA Series - Group D) Class II, Groups E, F, G All station boxes are drilled and tapped with 3/4" NPSM thread for operator, or pilot lights. Unused openings must be plugged with XPP plugs. XB style boxes are suitably padded for two conduit openings on one end and one on opposite end. 1" maximum conduit size. Box price includes one or two conduit openings; specify size, location and number of holes. Holes in panels should be 1-1/8" diameter with 1-3/4" centers for XB box. 211 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 5E–8 XA 15599 Sec.5 E 12/9/01 11:07 AM Page 212 Fittings and Accessories FSO & FDO OUTLET BOXES DRILLED & TAPPED TO ORDER Cast aluminum alloy (copper content 0.3% max) FSO can be tapped with 1” conduit maximum and FDO can be tapped with 1-1/2” conduit maximum. Two 3/4” maximum conduit holes in top and one hole in bottom. NOTE: Box can be rotated 180° to meet your needs. Catalog Number Outside Nominal Dimension W L D Description Standard Package Standard Pkg. Weight Lbs. FSO 3 4-3/4 1-3/4 Box, shallow type 20 20 FDO 3 4-3/4 2-3/4 Box, deep type 20 31 WSO 3 4-3/4 — Cover, weatherproof 10 2 (Furnished with screws & gasket) WSG FS21 Gasket, Neocork 1/2” conduit 3-1/16 5-1/2 1-3/4 5E–9 Box, shallow type, hub 20 15 FSH2 1/2” Female to 3/4” Male 50 4 FSH3 3/4” Female to 3/4” Male 50 3 FSP2 1/2” Conduit plug 100 2 FSP3 3/4” Conduit plug 100 3 212 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:10 AM Page 213 Explosionproof Enclosures With Threaded Cover Solid Threaded Cover Threaded Dome Cover Threaded Glass Cover Applications: • Adalet Junction Boxes and Instrument Housings are designed for installation in electrical conduit systems for hazardous environments. • Wiring: Pull boxes, splices, taps and terminal strips. • Housing for apparatus, instruments and other equipment. Features • Rugged sand-cast aluminum copper-free alloy — 0.3% max. copper content. • Tumblasted for quality appearance. • Cast-on mounting lugs, ease of field installation. • Grounding screw standard. Options • NEMA 3, 4 available; Features installation of an O-ring gasket on cover. • Conduit openings available, drilled and tapped to customer requirements. • Cast-on mounting buttons, bosses and pads available. 6A–1 Notes: Where reference is made to Class I and Class II hazardous locations, the equipment is suitable for use in both Division 1 and Division 2 hazardous locations. 213 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 214 Explosionproof Enclosures With Threaded Cover CLASS I GROUPS C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 XJD XJX XJHC XJDA XJS (Can be tapped on side pads only) XJM XJMA XJHB XJK XJL XJT XJMC XJHA XJKA XJN Certifications XJWH Compliance • NEC Class I, Groups C & D, Class II, Groups E, F & G • UL Standard 1203 • Investigated to CSA Standard C22.2 No. 30 by UL Drilled and tapped to specification, attach layout sheet. XJWT 6A–2 214 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 215 Explosionproof Enclosures With Threaded Window Cover METER AND INSTRUMENT HOUSINGS EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 XJDGC XJDFGC* XJMCGC* XJTGC XJTFGC* XJMGC* XJMAGC* XJXGC XJLGC * includes internal flange and meter mounting plate. XJNGC 6 & 12 XJHAGC XJHBGC XJHCGC XJKGC XJKAGC Certifications XJWHGC XJWTGC Compliance • NEC Class I, Groups C & D, Class II, Groups E, F & G • UL Standard 1203 • Investigated to CSA Standard C22.2 No. 30 by UL Drilled and tapped to specification, attach layout sheet. Back wall mounting plates optional on some housings. Consult factory. **XJOGC Enclosure is UL Classified and CSA Certified 215 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 6A–3 **XJOGC 15599 Sec.6 12/9/01 11:11 AM Page 216 Explosionproof Enclosures With Threaded Cover CLASS I GROUPS B, C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 XJDH XJXH XJHCH XJDAH XJSH (Can be tapped on side pads only) XJMH XJMAH XJHBH XJKH XJLH XJMCH XJKAH XJTH XJHAH XJNH 6 & 12 Certifications XJWHH Compliance • NEC Class I, Groups B, C & D, Class II, Groups E, F & G • UL Standard 1203 • Investigated to CSA Standard C22.2 No. 30 by UL Drilled and tapped to specification, attach layout sheet. XJWTH 6A–4 216 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 217 Explosionproof Enclosures With Threaded Window Cover METER AND INSTRUMENT HOUSINGS EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUPS B, C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 XJDGCH XJDFGCH* XJMCGCH* XJTGCH XJTFGCH* XJMGCH* XJMAGCH* XJXGCH XJLGCH * includes internal flange and meter mounting plate. XJNGCH 6 & 12 XJHAGCH XJHBGCH XJHCGCH XJKGCH XJKAGCH Certifications XJWTGCH Back wall mounting plates optional on some housings. Consult factory. Compliance • NEC Class I, Groups B, C & D, Class II, Groups E, F & G • UL Standard 1203 • Investigated to CSA Standard C22.2 No. 30 by UL Drilled and tapped to specification, attach layout sheet. 6A–5 XJWHGCH 217 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 218 Explosionproof Enclosures With Threaded Cover CLASS I GROUPS C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional) XJDX XJXX XJHCX XJDAX XJSX (Can be tapped on side pads only) XJMX XJMAX XJHBX XJKX Certifications XJWHX XJWTX XJLX XJMCX XJKAX XJTX XJHAX XJNX 6 & 12 6A–6 Compliance • NEC Class I, Groups C & D, Class II, Groups E, F & G • UL Standard 1203, 2279 • Investigated to CSA Standard C22.2 No. 30 by UL • CENELEC EN 50.014 & 50.018 EExd IIB+H2 IP60, (optional IP66 with o-ring seal) • IEC 79 Exd IIB + H2 IP60, (optional IP66 with o-ring seal) • Demko Certified 99E. 124129U • UL Classified, Class I, Zone 1, Group IIB Drilled and tapped to specification, attach layout sheet. 218 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 219 Explosionproof Enclosures With Threaded Window Cover METER AND INSTRUMENT HOUSINGS EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional) XJDGCX XJDFGCX* XJMCGCX* XJTGCX XJTFGCX* XJMGCX* XJMAGCX* XJXGCX XJLGCX * includes internal flange and meter mounting plate. XJNGCX 6 & 12 XJHAGCX XJHBGCX XJHCGCX XJKGCX XJKAGCX Certifications XJWTGCX Back wall mounting plates optional on some housings. Consult factory. 6A–7 XJWHGCX Compliance • NEC Class I, Groups C & D, Class II, Groups E, F & G • UL Standard 1203, 2279 • Investigated to CSA Standard C22.2 No. 30 by UL • CENELEC EN 50.014 & 50.018 EExd IIB+H2 IP60, (optional IP66 with o-ring seal) • IEC 79 Exd IIB + H2 IP60, (optional IP66 with o-ring seal) • Demko Certified 99E. 124129U • UL Classified, Class I, Zone 1 Drilled and tapped to specification, attach layout sheet. 219 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 220 Explosionproof Enclosures With Threaded Cover CLASS I GROUPS B, C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional) XJDHX XJXHX XJHCHX XJDAHX XJSHX (Can be tapped on side pads only) XJMHX XJMAHX XJHBHX XJKHX Certifications XJWHHX XJWTHX XJLHX XJMCHX XJKAHX XJTHX XJHAHX XJNHX 6 & 12 6A–8 Compliance • NEC Class I, Groups B, C & D, Class II, Groups E, F & G • UL Standard 1203, 2279 • Investigated to CSA Standard C22.2 No. 30 by UL • CENELEC EN 50.014 & 50.018 EExd IIB + H2 IP60, (optional IP66 with o-ring seal) • IEC 79 Exd IIB + H2 IP60, (optional IP66 with o-ring seal) • Demko Certified 99E.124129U • UL Classified, Class I, Zone 1, Group IIB + H2 Drilled and tapped to specification, attach layout sheet. 220 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 221 Explosionproof Enclosures With Threaded Window Cover METER AND INSTRUMENT HOUSINGS EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUPS B, C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 EExd IIB + H2 IP60; IP66 (optional); Exd IIB + H2 IP66 (optional) XJDGCHX XJDFGCHX* XJMCGCHX* XJTGCHX XJTFGCHX* XJMGCHX* XJMAGCHX* XJXGCHX XJLGCHX * includes internal flange and meter mounting plate. XJNGCHX 6 & 12 XJHAGCHX XJHBGCHX XJHCGCHX XJKGCHX XJKAGCHX Certifications XJWTGCHX Back wall mounting plates optional on some housings. Consult factory. • UL Standard 1203, 2279 • Investigated to CSA Standard C22.2 No. 30 by UL • CENELEC EN 50.014 & 50.018 EExd IIB + H2 IP60, (optional IP66 with o-ring seal) • IEC 79 Exd IIB + H2 IP60, (optional IP66 w/o-ring seal) • Demko Certified 99E.124129U • UL Classified, Class I, Zone 1, Group IIB + H2 Drilled and tapped to specification, attach layout sheet. 221 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 6A–9 XJWHGCHX Compliance • NEC Class I, Groups B, C & D, Class II, Groups E, F & G 15599 Sec.6 12/9/01 11:11 AM Page 222 Explosionproof Meter Instrument Housings METER AND INSTRUMENT HOUSINGS SQUARE WINDOW THREADED STYLE CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G; NEMA 7 & NEMA 9 Designed for 3 1/2" Rectangular Meters Non Magnetic Copper-free aluminum casting designed for specific instruments and meters Features Recessed window with no exposed hardware or protrusions on the cover. Provides clean finished appearance compatible with rectangular meters. Designed for 3 1/2" rectangular and 4 1/2" round meters. Furnished with cast inside mounting ears to support adapter plate for meter mounting. Interior neck opening has clearance for meter face, diagonal dimension 3 13/16" x 3 1/4". Mounting Can be surface mounted or panel mounted in panels up to 1/4" thick. Panel mounting requires 5 5/8" round opening allowing neck to protrude through the panel and the cover only appears on the front surface of the panel. Cover locks in position with set screw. For additional support, the front surface under the cover of the box can be drilled and tapped with blind holes on 5 1/2" x 5 1/2" centers for screw attachment. Requires countersunk screw openings in panel. XJSWGC For specific meter application consult factory. (Meter not included) 6A–10 Certifications • UL Classified E81696 • CSA Certified LR27991 Compliance • NEC Class I, Groups C & D, Class II, Groups E, F & G • UL Standard 1203 • CSA Standard C22.2 No. 30 Drilled and tapped to specification, attach layout sheet. 222 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 223 Explosionproof Enclosures With Threaded Cover JUNCTION BOXES THREADED DOME COVER STYLE EXPLOSIONPROOF AND DUST-TIGHT CLASS I, GROUP C & D; CLASS II GROUPS E, F, & G; NEMA 3, 4 (optional); NEMA 7, 9 XJLD XJTD XJHAD Without Cover To show Mounting Plate (Optional) XJHCD XJWT XJKD XJW XJKAD XJWH XJHAD XJSD XJW Modified To house transfer switch Modification (Not UL or CSA) ADALET Enclosure Systems • Designing Our Products Around Yours SM Compliance • NEC Class I, Division I, Groups C & D, Class II, Groups E, F & G • UL Standard 886 • CSA Standard C22.2 No. 30 Drilled and tapped to specification, attach layout sheet. 223 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 6A–11 Certifications • UL Listed E10493 • CSA Certified LR27991 15599 Sec.6 12/9/01 11:11 AM Page 224 Explosionproof Enclosures With Threaded Cover XJD XJK XJMGC XJKD (D is to glass retaining ring) (D is to underside of cover) Base Inside Nominal Overall Mounting Cover Window Catalog Dimensions Dimensions CL to C L Opening Viewing Dia. Dia. Number W L XJD 4 1/8 XJDGC 4 1/8 XJDFGC** XJDA D A B 4 1/8 3 7/8 5 5/16 4 1/8 4 1/16 5 5/16 4 1/8 4 1/8 4 1/16 5 3/4 5 3/4 Flange Max. Opening Conduit Mount. Ship. Bolt Wt. Size Size Pounds 5 3/4 C E F Dia. 5 5/16 4 7/8 6 3/16 3 3/4 3 3/4 - - 2 3/8 5 5/16 5 9/16 6 3/16 3 3/4 3 3/4 3 - 2 3/8 5 5 5/16 5 5/16 5 9/16 6 3/16 3 3/4 2 7/8 3 2 3/4 2 3/8 6 12 5 7/8 7 1/16 7 1/16 7 1/4 8 3/8 5 1/4 4 3/16 - - 2 3/8 XJS 4 DIA. 3 3/8 4 7/8 4 7/8 4 1/2 3 3/4 3 3/4 4 - - 1 1/4 3 XJSD 4 DIA. 4 7/16 4 7/8 4 7/8 5 1/2 3 3/4 3 3/4 4 - - 1 1/4 3 1/2 XJL 6 6 4 7/8 7 7 6 1/8 8 3/8 5 1/4 5 3/8 - - 2 3/8 11 XJLD4 6 6 8 9/16 7 7 9 7/8 8 3/8 5 1/4 5 3/8 - - 2 3/8 12 XJLD6 6 6 10 1/6 7 7 11 7/16 8 3/8 5 1/4 5 3/8 - - 2 3/8 12 1/4 XJLD10 6 6 14 9/16 7 7 15 15/16 8 3/8 5 1/4 5 3/8 - - 2 3/8 14 XJLD13 6 6 17 9/16 7 7 18 15/16 8 3/8 5 1/4 5 3/8 - - 2 3/8 15 XJLGC 6 6 3 7/8 7 7 6 3/16 8 3/8 5 1/4 5 3/8 4 - 2 3/8 11 XJT 5 13/16 6 9/16 5 7/16 6 13/16 7 9/16 6 5/8 7 3/4 6 5 3/8 - - 2 7/16 12 3/4 XJTD4 5 13/16 6 9/16 9 1/16 6 13/16 7 9/16 10 3/8 7 3/4 6 5 3/8 - - 2 7/16 13 1/2 XJTD6 5 13/16 6 9/16 10 9/16 6 13/16 7 9/16 11 15/16 7 3/4 6 5 3/8 - - 2 7/16 14 XJTD10 5 13/16 6 9/16 15 1/16 6 13/16 7 9/16 16 7/16 7 3/4 6 5 3/8 - - 2 7/16 15 1/2 XJTD13 5 13/16 6 9/16 18 1/16 6 13/16 7 9/16 19 7/16 7 3/4 6 5 3/8 - - 2 7/16 16 1/2 XJTGC 5 13/16 6 9/16 4 5/16 6 13/16 7 9/16 6 5/8 7 3/4 6 5 3/8 4 - 2 7/16 12 3/4 XJTFGC** 5 13/16 6 9/16 4 5/16 6 13/16 7 9/16 6 5/8 7 3/4 6 5 3/8 4 4 1/8 2 7/16 13 XJX 4 3/4 4 3/4 4 3/16 5 3/4 5 3/4 5 1/2 6 3/4 4 3/4 4 5/8 - - 2 1/4 7 XJXGC 4 3/4 4 3/4 3 5/16 5 3/4 5 3/4 5 3/8 6 3/4 4 3/4 4 5/8 3 - 2 1/4 7 XJM 6 3/4 6 3/4 10 3/16 7 3/4 7 3/4 11 11/16 9 1/8 6 1/4 7 - - 2 3/8 22 1/2 XJMGC** 6 3/4 6 3/4 9 1/8 7 3/4 7 3/4 11 1/2 9 1/8 6 1/4 7 5 1/4 5 3/8 2 3/8 22 1/2 XJMA 6 13/16 6 13/16 7 3/16 7 13/16 7 13/16 8 11/16 9 1/8 6 1/4 7 - - 2 3/8 17 XJMAGC** 6 13/16 6 13/16 6 1/8 7 13/16 7 13/16 8 1/2 9 1/8 6 1/4 7 5 1/4 5 1/4 2 3/8 17 XJMC 6 3/4 6 3/4 5 3/16 7 13/16 7 13/16 6 11/16 9 1/8 6 1/4 7 - - 2 3/8 13 1/2 XJMCGC** 6 3/4 6 3/4 4 1/8 7 13/16 7 13/16 6 1/2 9 1/8 6 1/4 7 5 1/4 5 3/8 2 3/8 13 3/4 6A–12 XJHA 7 3/16 9 3/16 5 1/4 8 3/16 10 3/16 6 3/4 9 3/4 8 3/4 7 - - 2 1/2 16 1/2 XJHAD6 7 3/16 9 3/16 11 8 3/16 10 3/16 12 7/16 9 3/4 8 3/4 7 - - 2 1/2 19 3/4 21 1/2 XJHAD9 7 3/16 9 3/16 14 8 3/16 10 3/16 15 7/16 9 3/4 8 3/4 7 - - 2 1/2 XJHAD12 7 3/16 9 3/16 17 8 3/16 10 3/16 18 7/16 9 3/4 8 3/4 7 - - 2 1/2 23 1/2 XJHAGC 7 3/16 9 3/16 4 3/16 8 3/16 10 3/16 6 9/16 9 3/4 8 3/4 7 5 1/4 - 2 1/2 16 1/2 XJHB 7 1/4 9 1/8 7 1/4 8 3/8 10 1/4 8 13/16 9 3/4 8 7/8 7 - - 2 1/2 22 XJHBGC 7 1/4 9 1/8 6 3/16 8 3/8 10 1/4 8 9/16 9 3/4 8 7/8 7 5 1/4 - 2 1/2 22 Note: Suffix H, X and HX enclosure types are dimensionally identical. **Includes built-in meter mounting provisions; call factory for details. 224 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 225 Explosionproof Enclosures With Threaded Cover Base Inside Nominal Overall Mounting Cover Window Flange Catalog Dimensions Dimensions CL to CL Opening Viewing Opening Conduit Bolt Dia. Dia. Number W L D A B C E F Dia. Max. Mount. Size Size Ship. Wt. Pounds XJHC 7 3/4 10 5/16 6 3/16 8 7/8 11 7/16 7 3/4 10 1/4 7 3/4 7 - - 2 1/2 23 1/2 XJHCD6 7 3/4 10 5/16 11 15/16 8 7/8 11 7/16 13 7/16 10 1/4 7 3/4 7 - - 2 1/2 26 3/4 XJHCD9 7 3/4 10 5/16 14 15/16 8 7/8 11 7/16 16 7/16 10 1/4 7 3/4 7 - - 2 1/2 28 1/2 XJHCD12 7 3/4 10 5/16 17 15/16 8 7/8 11 7/16 19 7/16 10 1/4 7 3/4 7 - - 2 1/2 30 1/2 XJHCGC 7 3/4 10 5/16 5 1/8 8 7/8 11 7/16 7 9/16 10 1/4 7 3/4 7 5 1/4 - 2 1/2 23 1/2 XJK 9 1/2 11 1/2 7 1/4 10 3/4 12 3/4 9 1/4 12 1/4 8 9 - - 3 1/2 39 1/4 XJKD6 9 1/2 11 1/2 13 1/16 10 3/4 12 3/4 14 15/16 12 1/4 8 9 - - 3 1/2 43 3/4 XJKD12 9 1/2 11 1/2 19 1/16 10 3/4 12 3/4 20 15/16 12 1/4 8 9 - - 3 1/2 49 XJKD18 9 1/2 11 1/2 25 1/16 10 3/4 12 3/4 26 15/16 12 1/4 8 9 - - 3 1/2 54 3/4 XJKGC 9 1/2 11 1/2 6 3/16 10 3/4 12 3/4 9 1/16 12 1/4 8 9 6 11/16 - 3 1/2 39 1/4 XJKA 9 1/2 11 1/2 9 1/8 10 3/4 12 3/4 11 3/16 12 3/8 8 9 - - 3 1/2 45 3/4 XJKAD6 9 1/2 11 1/2 15 10 3/4 12 3/4 16 13/16 12 3/8 8 9 - - 3 1/2 50 1/4 XJKAD12 9 1/2 11 1/2 21 10 3/4 12 3/4 22 13/16 12 3/8 8 9 - - 3 1/2 55 1/4 XJKAD18 9 1/2 11 1/2 27 10 3/4 12 3/4 28 13/16 12 3/8 8 9 - - 3 1/2 61 1/4 XJKAGC 9 1/2 11 1/2 8 1/16 10 3/4 12 3/4 11 12 3/8 8 9 6 11/16 - 3 1/2 45 3/4 14 5/8 9 13/16 15 3/8 9 10 11/16 - - 4 1/2 60 1/2 14 13/16 15 15/16 15 3/8 9 10 11/16 - - 4 1/2 87 1/2 XJN6 11 1/2 12 3/4 7 7/16 13 3/8 XJN12 11 1/2 12 3/4 13 9/16 13 9/16 XJNGC6 11 1/2 12 3/4 6 3/16 13 3/8 14 5/8 9 7/8 15 3/8 9 10 11/16 8 - 2 1/2 60 1/2 XJNGC12 11 1/2 12 3/4 12 5/16 13 9/16 14 13/16 16 15 3/8 9 10 11/16 8 - 2 1/2 87 1/2 XJWH 6 5/8 DIA 4 3/8 7 15/16 7 15/16 5 15/16 6 3/8 6 3/8 7 - - 2 3/8 11 1/2 XJWH6 6 5/8 DIA 10 1/8 7 15/16 7 15/16 11 5/8 6 3/8 6 3/8 7 - - 2 3/8 14 3/4 XJWH9 6 5/8 DIA 13 1/8 7 15/16 7 15/16 14 5/8 6 3/8 6 3/8 7 - - 2 3/8 16 1/2 XJWH12 6 5/8 DIA 16 1/8 7 15/16 7 15/16 17 5/8 6 3/8 6 3/8 7 - - 2 3/8 18 1/2 XJWHGC 6 5/8 DIA 3 5/16 7 15/16 7 15/16 5 3/4 6 3/8 6 3/8 7 5 1/4 - 2 3/8 11 1/2 XJW3 4 7/8 DIA 5 5/16 5 11/16 5 11/16 6 7/8 4 1/2 4 1/2 4 7/8 - - 1 1/4 1/4 5 XJW5 4 7/8 DIA 7 5/16 5 11/16 5 11/16 8 11/16 4 1/2 4 1/2 4 7/8 - - 1 1/4 1/4 5 3/4 XJWT 5 3/8 DIA 3 13/16 6 3/8 6 3/8 5 1/8 5 1/8 5 1/8 5 3/8 - - 2 5/16 8 XJWT4 5 3/8 DIA 7 9/16 6 3/8 6 3/8 8 7/8 5 1/8 5 1/8 5 3/8 - - 2 5/16 9 XJWT6 5 3/8 DIA 9 1/16 6 3/8 6 3/8 10 3/8 5 1/8 5 1/8 5 3/8 - - 2 5/16 9 1/2 XJWT10 5 3/8 DIA 13 9/16 6 3/8 6 3/8 14 7/8 5 1/8 5 1/8 5 3/8 - - 2 5/16 11 XJWT13 5 3/8 DIA 16 9/16 6 3/8 6 3/8 17 7/8 5 1/8 5 1/8 5 3/8 - - 2 5/16 12 XJWTGC 5 3/8 DIA 2 15/16 6 3/8 6 3/8 5 1/8 5 1/8 5 1/8 5 3/8 4 - 2 5/16 8 XJSWGC** XJOGC 5 1/4 5 1/4 4 1/16 6 1/8 6 1/8 5 5/8 7 1/8 4 3/4 5 3 3/8 x 3 3/8 3 3/4 3/4 5/16 8 8 8 5 1/4 9 9 7 9/16 8 8 7 5 1/4 - 2 5/16 20 1/4 6A–13 Note: Suffix H, X and HX enclosure types are dimensionally identical. **Includes built-in meter mounting provisions; call factory for details. 225 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 226 Conduit Drilling and Tapping Guidelines For Threaded Enclosure When drilling & tapping enclosures for conduit, proper installation requires compliance with the following: 1. Must be tapped with at least 5 full NPT threads (suffix X enclosures require 6 NPT threads) in enclosure back or sides only; min. 1/2" conduit size. 2. Tapping depth of NPT holes must be plus 1/2 turn min. to plus 1-1/2 turns max. past standard NPT plug gage notch. 3. Inner end of conduit openings shall be smooth and well-rounded. TABLE I Trade Size Of Minimum wall thickness at Conduit, Inches (NPT) conduit entrance excluding suffix X enclosures (XCEX) 1/2 - 3/4 3/8 inch 1-2 7/16 inch 2 1/2 - 5 5/8 inch TABLE II Conduit size, inches (NPT) 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 Minimum Distance from conduit CL to inside corner or back of box 1 5/16 1 7/16 1 9/16 1 3/4 1 7/8 2 1/8 2 3/8 2 11/16 2 15/16 3 1/4 Approximate diameter of union 1 7/8 1 7/8 2 1/16 2 7/8 3 1/4 3 7/8 4 7/8 5 1/2 6 6 1/2 TABLE III NPT (METRIC) THREADS SIZE 5 4 3 1/2 3 (M75) 2 1/2 (M63) 2 (M50) 1 1/2 (M40) 1 1/4 (M32) 1 (M25) 3/4 (M20) 1/2 (M16) 1/16 - 3/8 1/16-3/8 NPT 4 3/8 3 5/8 3 3/8 3 2 5/8 2 3/8 2 1 7/8 1 5/8 1 3/8 1 1/4 1 1/8 1/2 (M16) 4 3/8 3 5/8 3 3/8 3 2 5/8 2 3/8 2 1 7/8 1 5/8 1 3/8 1 1/4 3/4 (M20) 4 1/2 3 3/4 3 1/2 3 1/8 2 3/4 2 1/2 2 1/8 2 1 3/4 1 1/2 1 (M25) 4 5/8 3 7/8 3 5/8 3 1/4 2 7/8 2 3/4 2 1/4 2 1/8 1 7/8 1 1/4 (M32) 4 7/8 4 1/8 3 7/8 3 1/2 3 1/8 2 7/8 2 1/2 2 3/8 1 1/2 (M40) 5 4 1/4 4 3 5/8 3 1/4 3 2 5/8 2 (M50) 5 3/8 4 3/4 4 1/2 4 3 5/8 3 3/8 2 1/2 (M63) 5 1/2 4 7/8 4 5/8 4 1/4 3 7/8 3 (M75) 5 7/8 5 1/4 5 4 5/8 3 1/2 6 1/4 5 3/4 5 1/2 4 6 7/8 6 5 7 3/8 This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and conditions under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. 6A–14 Note: All dimensions are in inches. The Adalet engineering department is available to provide custom explosionproof enclosures for your products. 226 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 227 Explosionproof Enclosures With Threaded Cover METER & INSTRUMENT HOUSINGS EXPLOSIONPROOF AND DUST-TIGHT DRILLING & TAPPING LAYOUT INSTRUCTIONS Consult factory for extensive machining options, i.e. mounting of operators, thread type and size thru wall, mounting pans. Layout data sheets available. MINIMUM DISTANCE BETWEEN CENTERS OF AUXILIARY DEVICES AND CONDUIT ENTRIES SIZE 5 NPSM 4 NPSM 3 1/2 NPSM 3 NPSM 2 1/2 NPSM 2 NPSM 1 1/2 NPSM 1 1/4 NPSM 1 NPSM 3/4 NPSM 1/4-3/8 NPSM 1/4-1 UN 1/16-3/8 NPT 4 3/8 3 5/8 3 3/8 3 2 5/8 2 3/8 2 1 7/8 1 5/8 1 3/8 1 1/4 1 1/8 1/2NPT (M16) 4 3/8 3 5/8 3 3/8 3 2 5/8 2 3/8 2 1 7/8 1 5/8 1 3/8 1 1/4 3/4 NPT (M20) 4 1/2 3 3/4 3 1/2 3 1/8 2 3/4 2 1/2 2 1/8 2 1 3/4 1 1/2 1 NPT (M25) 4 5/8 3 7/8 3 5/8 3 1/4 2 7/8 2 3/4 2 1/4 2 1/8 1 7/8 1 1/4 NPT (M32) 4 7/8 4 1/8 3 7/8 3 1/2 3 1/8 2 7/8 2 1/2 2 3/8 1 1/2 NPT (M40) 5 4 1/4 4 3 5/8 3 1/4 3 2 5/8 5 3/8 4 3/4 4 1/2 4 3 5/8 3 3/8 5 1/2 4 7/8 4 5/8 4 1/4 3 7/8 3 NPT (M75) 5 7/8 5 1/4 5 4 5/8 3 1/2 NPT 6 1/4 5 3/4 5 1/2 4 NPT 6 7/8 6 5 NPT 7 3/8 2 NPT (M50) 2 1/2 NPT (M63) MINIMUM DISTANCE BETWEEN CENTERS OF AUXILIARY DEVICES 5 NPSM 4 NPSM 3 1/2 NPSM 3 NPSM 2 1/2 NPSM 2 NPSM 1 1/2 NPSM 1 1/4 NPSM 1 NPSM 3/4 NPSM 1/4-3/8 NPSM 1/4-1 UN 1/4-1 UN 4 3/8 3 5/8 3 3/8 3 2 5/8 2 3/8 2 1 7/8 1 5/8 1 3/8 1 1/4 1 1/8 1/4-3/8 NPSM 4 3/8 3 5/8 3 3/8 3 2 5/8 2 3/8 2 1 7/8 1 5/8 1 3/8 1 1/4 3/4 NPSM 4 1/2 3 3/4 3 1/2 3 1/8 2 3/4 2 1/2 2 1/8 2 1 3/4 1 1/2 1 NPSM 4 5/8 3 7/8 3 5/8 3 1/4 2 7/8 2 3/4 2 1/4 2 1/8 1 7/8 1 1/4 NPSM 4 7/8 4 1/8 3 7/8 3 1/2 3 1/8 2 7/8 2 1/2 2 3/8 1 1/2 NPSM 5 4 1/4 4 3 5/8 3 1/4 3 2 5/8 2 NPSM 5 3/8 4 3/4 4 1/2 4 3 5/8 3 3/8 2 1/2 NPSM 5 1/2 4 7/8 4 5/8 4 1/4 3 7/8 3 NPSM 5 7/8 5 1/4 5 4 5/8 3 1/2 NPSM 6 1/4 5 3/4 5 1/2 4 NPSM 6 7/8 6 5 NPSM 7 3/8 6A–15 SIZE 227 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.6 12/9/01 11:11 AM Page 228 Quick Reference Guide METHODS OF PROTECTION Area Division 1 Division 2 Area Zone 0 Zone 1 Zone 2 Protection Method UL CSA CENELEC Explosionproof Intrinsically Safe (2 Fault) Purge/Pressurized (Type X or Y) Nonincendive Non-sparking device Purge/Pressurized (Type Z) Hermetically sealed Any Class I, Division 1 Method Protection Method Intrinsically Safe 'ia' (2 Fault) Flameproof 'd' Increased Safety 'e' Intrinsically Safe 'ib' (1 Fault)0 Encapsulation 'm' Oil Immersion 'o' Purged/Pressurized 'p' Powder filling 'q' Any Zone 0 Method Non-sparking 'nA' Hermetically sealed 'nC' Nonincendive 'nC' Restricted breathing 'nR' Any Zone 0 or 1 Method ANSI/UL 1203 CSA-30 -- -- ANSI/UL 913 CSA-157 -- -- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 UL 1604 CSA-213 CSA-213 --- --- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 CSA-213 -- -- -- -- -- -- UL (AEx) CSA (Ex) CENELEC (EEx) IEC (Ex) UL 2279 Pt. 11 CSA-E79-18 EN 50028 IEC 60 079-18 UL 2279 Pt. 1 UL 2279 Pt. 7 CSA-E79-1 CSA-E79-7 EN 50018 EN 50019 IEC 60 079-1 IEC 60 079-7 UL 2279 Pt. 11 CSA-E79-11 EN 50020 IEC 60 079-11 UL 2279 Pt. 18 UL 2279 UL 2279 Pt. 2 UL 2279 -UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 -- CSA-E79-18 CSA-E79-6 CSA-E79-2 CSA-E79-5 -CSA-E79-15 CSA-E79-15 CSA-E79-15 CSA-E79-15 -- EN 50028 EN 50015 EN 50016 EN 50017 -prEN 50021 prEN 50021 prEN 50021 prEN 50021 -- IEC 60 079-18 IEC 60 079-6 IEC 60 079-2 IEC 60 079-5 -IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 -- TEMPERATURE CLASSES AREA CLASSIFICATIONS Ignitable Materials Present Continuously Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Zone 0 (Zone 20 Dust) Zone 0 Division 1 Zone 1 (Zone 21 Dust) Zone 1 Division 1 Zone 2 (Zone 22 Dust) Zone 2 Division 2 IEC/CENELEC NEC 505 NEC 500 ATEX Classification by Group & Category According to Use Ignitable Materials Present Continuously Equipment Group II Category 1 Equipment (surface) Equipment Group I Category M1 Equipment (mining) IEC Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Category 2 Equipment Category 3 Equipment Category M2 Equipment — GAS GROUPINGS Gas, Dust or Fiber NEC 505/IEC/CENELEC NEC 500 Acetylene Hydrogen Ethylene Propane Methane Metal Dust Coal Dust Grain Dust Fibers Group IIC Group IIC/Group IIB+H2 Group IIB Group IIA Group I (firedamp) None None None None Class I/Group A Class I/Group B Class I/Group C Class I/Group D Class I/Group D Class II/Group E Class II/Group F Class II/Group G Class III ACRONYMS CENELEC - European Committee for Electrotechnical Standardization IEC - International Electrotechnical Commission NEC - National Electrical Code U.L. - Underwriters Laboratories C.S.A. - Canadian Standards Association FM - Factory Mutual BASEEFA - British Approvals Service for Electrical Apparatus in Flammable Atmospheres NFPA - National Fire Protection Agency ISO - International Organization for Standardization ANSI - American National Standard Institute ATEX - Atmospheres Explosibles Maximum Surface Temperature NEC 505 IEC CENELEC 450°C 300°C 280°C 260°C 230°C 215°C 200°C 180°C 165°C 160°C 135°C 120°C 100°C 85°C T1 T2 T3 T4 T5 T6 NEC 500 T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 INGRESS PROTECTION (IP XX) CODES # First Number (Protection against Solid Bodies) Second Number (Protection against Liquids) 0 1 2 3 4 5 6 7 8 No protection Objects greater than 50mm Objects greater than 12mm Objects greater than 2.5mm Object greater than 1mm Dust Protected Dust-tight --- No protection Vertically dripping water 75-90 Deg. dripping water Sprayed water Splashed water Water jets Heavy seas Effects of immersion Indefinite immersion 7A–1 15599 Sec.7 12/9/01 11:14 AM Page 229 FS Control3 Specifications FS Control3 We named this line of control stations FS Control3 because we offer it in three different material types – carbon steel, stainless steel and fiberglass – to meet your control station needs. Each material type has certain properties and characteristics that make it well-suited for certain applications. If you would like assistance in determining which enclosure type best fits your application, please consult our engineering department. Features and Benefits Compliances • The normally open/normally closed factory sealed contact block is rated both NEMA A600 and NEMA Q300 X2CS, X2SS, and X2FG Series: UL Standard 698, 1604 and 2279 Canadian Standards Association C22.2 No. 213-M1987 NEC Class I, Division 2, Groups ABCD; Class II, Division 2, Groups FG; Class III NEC Class I, Zone 2, Group IIC • Electrical ratings for pilot lights range between 6 volts and 480 volts • Carbon steel, stainless steel and fiberglass control station enclosure types available in one- through four-hole arrangements to accommodate a wide variety of system needs. Other configurations are available - consult factory X2CS Series: NEMA Type 3, 3R, 7ABCD (Division 2), 12 and 13, 4 • Conduit hub entries available in 1/2", 3/4" and 1" sizes either dead-end or feed through X2FG and X2SS Series: NEMA Type 3, 3R, 4, 4X, 7ABCD (Division 2), 12, 13 • Broad new line of 30mm industrial pilot lights, pushbuttons and selector switches allows thousands of possible control station configurations Factory Sealed Contact Block: Underwriters Laboratories – UL698, UL 1203, UL1604 and UL2279 Class I, Division 1, Groups ABCD Class I, Zone 1, Group IIC Class I, Division 2, Groups ABCD Class I, Zone 2, Group IIC Canadian Standards Association C22.2 No. 213-M1987 Class I, Div. 2, Groups BCD • High-quality legend plates permit easy identification of device function Material/Finish • Enclosures: X2CS – Made from 14 ga. cold-rolled steel with continuously welded seams ground to a smooth finish. Each X2CS enclosure comes complete with a grounding stud and wall mounting back brackets welded to the outside top and bottom. Phosphatized and finished inside and out with ANSI/ASA 61 gray polyester powder coating. Pilot Lights: Listed Underwriters Laboratories: Class I, Division 2, Groups ABCD X2SS – Made from 14 ga. Type 304 stainless steel with continuously welded seams ground to a smooth finish. Each X2SS comes complete with a grounding stud and wall mounting brackets welded to the outside top and bottom. Finished with #4 brush. X2FG – Made from compression-molded, fiberglassreinforced polyester. Each X2FG comes complete with a grounding strap and optional mounting brackets can be provided. Molded standard machine tool gray. Certifications LISTED X2CS Series: Type 12, 4 • Industrial Pilot Device Bodies: PBT Polyester • Industrial Pilot Device Caps: PBT Polyester X2FG and X2SS Series: Type 3, 4X, 12 and 13 • Industrial Pilot Device Clamp Rings: Polyester (standard) or aluminum Application • For installation in Division 2 areas of chemical and petrochemical plants, refineries and other process industries where flammable vapors, gases or combustible dust may be present due to accidental or abnormal operation LISTED • For use with Adalet 30mm pushbuttons, selector switches and pilot lights to provide circuit/motor control and/or electrical status indication LISTED ADALET Enclosure Systems • Designing Our Products Around Yours SM X2CS, X2SS, and X2FG Series: Listed Underwriters Laboratories: Class I, Division 2, Groups BCD; Class I, Zone 2, Group IIB+H2; Class II, Division 2, Groups FG; Factory Sealed Contact Block: Listed Underwriters Laboratories: Class I, Division 2, Groups BCD Class I, Zone 2, Group IIB+H2 Certified Canadian Standards Association Class I, Div. 2, Groups BCD Pilot Lights: Listed Underwriters Laboratories: Class I, Division 2, Groups ABCD 229 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 230 7A–2 Pushbutton Operators for Use with FS Control3 Pushbutton Operators with Polyester Clamp Ring Cap Color Green Black Red Flush Cap Suffix Extended Cap Suffix Mushroom Cap Suffix PBO-FCGN-FS PBO-FCBK-FS PBO-FCRD-FS 1TS 2TS 3TS PBO-XCGN-FS PBO-XCBK-FS PBO-XCRD-FS 4TS 5TS 6TS PBO-MCGN-FS PBO-MCBK-FS PBO-MCRD-FS 7TS 8TS 9TS For additional NO/NC contact block add “/FS” to end of catalog number For aluminum clamp ring, add “A” after first dash in catalog number. Example – PBO-AXCRD-FS is red extended cap pushbutton with aluminum clamp ring. Note: Caps and operating heads are available in a variety of styles and colors – please consult factory Maximum Ampere Rating Control Circuit Contacts Type FSBT AC (A600) 600 VAC max DC (Q300) Volts 110 220 440 550 120 240 Make & Interrupting Capacity Normal Load Break Continuous Current 60 6 10 30 3 10 15 1.5 10 12 1.2 10 .55 .55 2.5 .27 .27 2.5 Catalog No. FSBT One Normally Open and One Normally Closed. Illuminated Pushbuttons Unit Complete Less Cap1 Type Volts Transformer 50/60 Hz Full Voltage Type Neon Type 2 Incandescent LED Resistor Type 4 Dual Input Remote Test Catalog Number Suffix AC AC AC AC 3 TFLU120FS TFLU240FS TFLU480FS TFLU277FS 10TS 11TS 12TS 13TS 6 AC/DC 12 AC/DC 24 AC/DC 120 AC/DC FVLU6FS FVLU12FS FVLU24FS FVLU120FS 14TS 15TS 16TS 17TS 120 AC/DC 240 AC/DC 480 AC/DC FVLU120NFS FVLU240NFS FVLU480NFS 18TS 19TS 20TS 120 AC/DC 240 AC/DC RLU120IFS RLU240IFS 21TS 22TS 120 AC/DC 240 AC/DC RLU120LFS RLU240LFS 23TS 24TS 6 AC/DC 12 AC/DC 24 AC/DC 120 AC/DC 240 AC/DC RTLU6FS RTLU12FS RTLU24FS RTLU120FS RTLU240FS 25TS 26TS 27TS 28TS 29TS 120 240 480 277 Color Caps for Illuminated Pushbuttons 5 Color Cap with Polyester Clamp Ring Color Amber Blue Clear Green Red White Catalog Number Suffix IPBCAR IPBCBE IPBCCR IPBCGN IPBCRD IPBCWE 30TS 31TS 32TS 33TS 34TS 35TS For aluminum clamp ring, add “A” prefix to color cap catalog number. Example – AIPBCBE is blue color cap for illuminated pushbutton with aluminum clamp ring. Footnotes 1 To order as an assembled illuminated pushbutton with color cap, add color cap catalog number to the end of illuminated pushbutton catalog number. Example – TFLU120FS-IPBCRD would be complete illuminated pushbutton with red cap. 2 Neon lights are available with red or green lamps. Add suffix letter “R” or “G” respectively to designate color. Use amber, clear or red cap only for red neon lights; green or clear cap only for green neon lights. 3 120 Volt incandescent lamps are not recommended when the unit is subjected to shock and/or vibration. A transformer, resistor, neon or LED unit will provide longer lamp life. 4 Specify LED lamp color. Add suffix letter “R” for red, “G” for green and “Y” for yellow (amber). Use amber, clear or red cap only for red lights; green or clear cap only for green lights; red, clear or amber for yellow lights. 5 Catalog numbers are for extended color caps. For flush guarded color caps, add suffix “EECR” to the catalog number. 230 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7A–3 15599 Sec.7 12/9/01 11:14 AM Page 231 Push-Twist/Push-Pull Operators for Use with FS Control3 2 Position Push-Twist Release Maintained Operators Non-Illuminated 2 Position Push-Pull Maintained Operators Non-Illuminated Maintained In/Maintained Out Color Black Red Green Yellow Maintained In/Maintained Out Catalog Number Suffix Color PTR-TMCBK-FS PTR-TMCRD-FS PTR-TMCGN-FS PTR-TMCYW-FS 36TS 37TS 38TS 39TS Black Red Green Yellow Catalog Number Suffix PBO-PPMCBK-FS PBO-PPMCRD-FS PBO-PPMCGN-FS PBO-PPMCYW-FS 40TS 41TS 42TS 43TS For aluminum clamp ring, add “A” after first dash in catalog number. Example – PTR-ATMCGN-FS is 2 position push-twist release operator with green cap and aluminum clamp ring. For aluminum clamp ring, add “A” after first dash in catalog number. Example – PBO-APPMCYW-FS is 2 position push-pull operator with yellow cap and aluminum clamp ring. Note: For additional NO/NC contact block add “/FS” to end of catalog number. Note: For additional NO/NC contact block add “/FS” to end of catalog number. 2 Position Push-Pull Release Maintained Operators Illuminated Maintained In/Maintained Out Type Transformer 60/50 Hz Full Voltage Incandescent Resistor Volts Catalog Number Suffix TFPPM120-IMCRD-FS TFPPM240-IMCRD-FS TFPPM480-IMCRD-FS TFPPM600-IMCRD-FS 44TS 45TS 46TS 47TS 6 AC/DC 12 AC/DC 24 AC/DC 120 AC/DC 120 AC/DC Neon FVPPM6-IMCRD-FS FVPPM12-IMCRD-FS FVPPM24-IMCRD-FS FVPPM120-IMCRD-FS FVPPM120NR-IMCRD-FS 48TS 49TS 50TS 51TS 52TS 120 AC/DC 240 AC/DC RLPPM120-IMCRD-FS RLPPM240-IMCRD-FS 53TS 54TS 120 240 480 600 AC AC AC AC For aluminum clamp ring, add “A” after first dash in catalog number. Example – FVPPM6-AIMCRD-FS is full voltage 2 position push-pull release illuminated operator with aluminum clamp ring. Note: Standard color cap on 2 position push-pull illuminated operator is red. Additional color caps are available – please consult factory. 231 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 232 7A–4 Selector Switch Units for Use with FS Control3 (STANDARD) MOUNTING POSITION A MOUNTING POSITION B CONTACT BLOCK SHOWN MOUNTED IN POSITION B VIEWED FROM BACK 2 Position Selector Switch Units Assembled with Polyester Clamp Ring (partial listing)1 Mounting Position Contact Symbol A &B Handle Position Left / Right O=Open, X=Closed O X X O Type of Operator Maintained Position Suffix Spring Return – Right to Left Suffix Spring Return – 2 Left to Right Suffix Standard SS02-SHWE-FS 55TS SRORL-SHWE-FS 60TS SROLR-SHWE-FS 63TS Lever SS02-SLWE-FS 56TS SRORL-SLWE-FS 61TS SROLR-SLWE-FS 64TS Key Locking Pos Left Right Both K0SS2-KL-FS K0SS2-KR-FS K0SS2-KLR-FS 57TS 58TS 59TS KOSRRL-KLFS — — 62TS — — — For aluminum clamp ring on standard or lever, add “A” after first dash in catalog number. Example – SS02-ASHWE-FS is standard 2 position selector switch unit maintained position with aluminum clamp ring. For aluminum clamp ring on key, add “A” to beginning of catalog number. Example – AKOSS2-KL-FS is 2 position key selector switch key locking left with aluminum clamp ring. Optional contact sequences available upon request. Contact block mounted standard in “A” position. To order additional contact block for “B” mounting position, add “/FS” to the end of the catalog number. 3 Position Selector Switch Units Assembled with Polyester Clamp Ring (partial listing)1 Mounting Position Contact Symbol Handle Position Left /Center/Right O=Open, X=Closed X O O O X O A O O X O X O B Spring Return – Left to Center Suffix Spring Return – Right to Center Maintained Position Suffix Standard SSO3-SHWE-FS 65TS SRORLC-SHWE-FS 73TS SRORC-SHWE-FS 81TS SROLRC-SHWE-FS 89TS Lever SS03-SLWE-FS 66TS SRORLC-SLWE-FS 74TS SRORC-SLWE-FS 82TS SROLRC-SLWE-FS 90TS Key Locking Pos Left Right Both K0SS3-KL-FS K0SS3-KR-FS K0SS3-KC-FS 67TS 68TS 69TS KOSRLC-KL-FS KOSRLC-KR-FS KOSRLC-KC-FS 75TS 76TS 77TS Key Locking Pos Left & Right Left & Center Right & Center KOSS3-KLR-FS KOSS3-KLC-FS KOSS3-KRC-FS 70TS 71TS 72TS KOSRLC-KLR-FS KOSRLC-KLC-FS KOSRLC-KRC-FS 78TS 79TS 80TS KOSRRC-KL-FS KOSRRC-KR-FS KOSRRC-KC-FS Suffix Spring Return – Either to Center Type of Operator 83TS 84TS 85TS KOSRLRC-KL-FS KOSRLRC-KR-FS KOSRLRC-KC-FS KOSRRC-KLR-FS 86TS KOSRLRC-KLR-FS KOSRRC-KLC-FS 87TS KOSRLRC-KLC-FS KOSRRC-KRC-FS 88TS KOSRLRC-KRC-FS Suffix 91TS 92TS 93TS 94TS 95TS 96TS For aluminum clamp ring on standard or lever, add “A” after first dash in catalog number. Example – SSO3-ASLWE-FS is lever 3 position selector switch unit maintained position with aluminum clamp ring. For aluminum clamp ring on key, add “A” to beginning of catalog number. Example – AKOSS3-KLR-FS is 3 position key selector switch key locking left and right with aluminum clamp ring. Optional contact sequences available upon request. Specific key removable positions are available – consult factory. Contact block mounted standard in “A” position. To order additional contact block for “B” mounting position, add “/FS” to the end of the catalog number. Footnotes 1 Catalog numbers for standard and lever operators identify black operators with white color insert. Consult factory for other available colors. 2 Spring Return Left to Right uses a reverse cam and the contact block selection is the opposite as shown as standard. 232 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7A–5 15599 Sec.7 12/9/01 11:14 AM Page 233 Pilot Lights for Use with FS Control3 Standard Pilot Lights Unit Complete Less Cap Type Volts Catalog Number Suffix TFLU120 TFLU240 TFLU480 TFLU277 97TS 98TS 99TS 100TS FVLU6 FVLU12 FVLU24 FVLU120 101TS 102TS 103TS 104TS 120 AC/DC 240 AC/DC 480 AC/DC FVLU120N FVLU240N FVLU480N 105TS 106TS 107TS 120 AC/DC 240 AC/DC RLU120I RLU240I 108TS 109TS 120 AC/DC 240 AC/DC RLU120L RLU240L 110TS 111TS 120 AC/DC 240 AC/DC RTLU120 RTLU240 112TS 113TS Transformer 50/60 Hz Full Voltage Type Neon Type AC AC AC AC 6 AC/DC 12 AC/DC 24 AC/DC 120 AC/DC 2 1 Incandescent LED Resistor Type 120 240 480 277 3 Dual Input Remote Test Footnotes Color Cap with Polyester Clamp Ring Color Catalog Number Suffix PLLAR PLLBE PLLCR PLLGN PLLRD PLLWE 126TS 127TS 128TS 129TS 130TS 131TS Amber Blue Clear Green Red White For aluminum clamp ring, add “A” prefix to color cap catalog number. Example – APLLBE is blue color cap for standard pilot light with aluminum clamp ring. LED Lamps 1 Neon lights are available with red or green shock and/or vibration. A transformer, resistor, neon or LED unit will provide longer lamp life. lamps. Add suffix letter “R” or “G” respectively to designate color. Use amber, clear or red cap only for red neon lights; green or clear cap only for green neon lights. 3 Specify LED lamp color. Add suffix letter “R” for red, “G” for green and “Y” for yellow (amber). Use amber, clear or red cap only for red lights; green or clear cap only for green lights; red, clear or amber for yellow lights. 2 120 Volt incandescent lamps are not recommended when the unit is subjected to Push-to-Test Pilot Lights Unit Complete Less Cap Type Transformer 50/60 Hz Full Voltage Type Neon Type Color Caps for Standard Pilot Lights 1 Incandescent Resistor Type LED Resistor Type 3 Volts Catalog Number Suffix 120 AC 240 AC 480 AC TFPTT120FS TFPTT240FS TFPTT480FS 114TS 115TS 116TS 6 AC/DC 12 AC/DC 24 AC/DC 2 120 AC/DC FVPTT6FS FVPTT12FS FVPTT24FS FVPTT120FS 117TS 118TS 119TS 120TS 120 AC/DC 240 AC/DC 480 AC/DC FVPTT120NFS FVPTT240NFS FVPTT480NFS 121TS 122TS 123TS 120 AC/DC RLPTT120FS 124TS 120 AC/DC RLPTT120LFS 125TS Footnotes 1 Neon lights are available with red or green lamps. Add suffix letter “R” or “G” respectively to designate color. Use amber, clear or red cap only for red neon lights; green or clear cap only for green neon lights. 2 120 Volt incandescent lamps are not recommended when the unit is subjected to shock and/or vibration. A transformer, resistor, neon or LED unit will provide longer lamp life. 3 Specify LED lamp color. Add suffix letter “R” for red, “G” for green and “Y” for yellow (amber). Use amber, clear or red cap only for red lights; green or clear cap only for green lights; red, clear or amber for yellow lights. 4 Catalog numbers are for extended color caps. For flush guarded color caps, add suffix “EECR” to the catalog number. Transformer lights and full voltage 6, 12 and 24 volt lights can be provided with solid state long life LED lamps in place of the standard incandescent lamps. Adalet’s LED lamps are in a miniature bayonet base for direct interchangeability and feature an ultra bright 4 LED cluster with light output comparable to a standard type 755 incandescent lamp. The 4 LEDs are built into two circuits for redundancy and include internal current limiting resistors. Lamps are available in red, green, and yellow. How to Order Add the letter “L” plus the first letter of the color to the light catalog number. Example: Catalog number TFLU120LR would be a transformer light with red LED lamp. Color Caps for Push-to-Test Pilot Lights 4 Color Cap with Polyester Clamp Ring Color Amber Blue Clear Green Red White Catalog Number Suffix IPBCAR IPBCBE IPBCCR IPBCGN IPBCRD IPBCWE 30TS 31TS 32TS 33TS 34TS 35TS For aluminum clamp ring, add “A” prefix to color cap catalog number. Example – AIPBCBE is blue color cap for push-to-test pilot light with aluminum clamp ring. 233 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 234 7A–6 Legend Plates for Use with FS Control3 Standard Legend Plates Description Catalog Number Prefix Standard Narrow Short LP LPN LPS Height (inches) Width (inches) Characters Per Line Number of Lines 2 2 2 1 3/4 2 16 16 16 2 2 2 1 3/4 Legend plates are available in the three styles listed above plus the IEC standard emergency legend plate shown to the right. Standard is black background with white letters except -05 and -28 which are red background with white letters. Other colors are available – consult factory. Plates with special legends are available – consult factory. Standard Legends Pushbuttons and Lights 2 Position Selector 3 Position Selector Catalog No. Suffix Legend Left Legend Right Catalog No. Suffix Legend Left Legend Center Legend Right Catalog No. Suffix 01 02 03 04 Auto Auto Down Fast Hand Manual Up Slow 50 68 51 63 Down Fwd Fwd Hand Off Auto Off Off Up Rev Rev Auto 80 81 82 83 05 Fwd Rev 52 Manual Off Auto 84 Fast Forward Hand Inch Jog 06 07 08 09 10 Hand Inch Manual Off On Auto Run Auto On Off 53 54 55 56 57 Off Off Off 1 1 Run Start 1 Off 2 Start Run 2 2 3 89 85 86 87 88 Manual Motor Run Off On Overload 11 26 12 13 27 Open Push On Pull Start Push Off Push to Stop Close Push Off Push Stop Pull On Pull to Start 58 64 65 66 67 Open Power Off Power On Push-to-Reset Push-to-Test 14 15 16 30 17 Rev Run Slow Start Stop Fwd Jog Fast Stop Start 59 60 69 61 62 Reset Reverse Run Slow Start 18 19 20 21 22 Stop Stop (red) Test Trip Up 23 28 24 29 25 Legend Auto Close Down Emergency Stop Emergency Stop (red) Options • Laser engraving on legend plates • Legend plates available in white, red and aluminum in addition to standard black • Round, yellow legend plates. 234 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7A–7 15599 Sec.7 12/9/01 11:14 AM Page 235 FS Control3 Dimensions 7/32 DIA. MTG. HOLES 4 7/8 4 5/16 C 6 1/16 5 1/2 B C F B .201 DIA. K MTG. HOLES K G A G A 6 1/8 6 7/16 J 5 5 5/16 J STAINLESS STEEL & CARBON STEEL F FIBERGLASS Dimensions Stainless Steel (X2SS) & Carbon Steel (X2CS) Body Style Outside Dimensions Mounting Dimensions 1/2" Hubs 3/4" Hubs 1" Hubs A B C F G J K J K J K 1 Hole 4 5/16 4 5/16 5 3 1/8 4 1/2 13/16 1 1/2 7/8 1 1/2 1 1 1/2 2 Holes 6 5/16 4 5/16 5 3 1/8 6 1/2 13/16 1 1/2 7/8 1 1/2 1 1 1/2 3 Holes 8 5/16 4 5/16 5 3 1/8 8 1/2 13/16 1 1/2 7/8 1 1/2 1 1 1/2 4 Holes 10 5/16 4 5/16 5 3 1/8 10 1/2 13/16 1 1/2 7/8 1 1/2 1 1 1/2 Dimensions Fiberglass (X2FG) Body Style Outside Dimensions Mounting Dimensions 1/2" Hubs 3/4" Hubs 1" Hubs A B C F G J K J K J K 1 Hole 6 5/8 3 13/16 3 7/8 2 15/16 4 7/8 13/16 1 1/2 7/8 1 1/2 1 1 1/2 2 Holes 6 5/8 3 13/16 3 7/8 2 15/16 4 7/8 13/16 1 1/2 7/8 1 1/2 1 1 1/2 3 Holes 8 7/8 3 13/16 3 7/8 2 15/16 7 1/8 13/16 1 1/2 7/8 1 1/2 1 1 1/2 4 Holes 11 1/8 3 13/16 3 7/8 2 15/16 9 3/8 13/16 1 1/2 7/8 1 1/2 1 1 1/2 235 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 236 7A–8 FS Control3 Catalog Logic Catalog Logic/Example Enclosure Type Cover Holes Entry Hub Size Industrial Industrial Pilot Pilot Devices Devies TOP BOTTOM X2CS - Carbon Steel X2SS - Stainless Steel X2FG - Fiberglass 1234- 1 Hole 2 Holes 3 Holes 4 Holes T - Top Feed B - Bottom Feed F - Feed Through Order pilot devices utilizing the suffix number from the tables on pages 7A–2 to 7A–5. (Also, remember to select legend plates from page 7A–6.) 2 - 1/2" Hub 3 - 3/4" Hub 4 - 1" Hub The above example is a carbon steel control station, 4 holes, with feed through and 1/2" hub. Hubs included. 236 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7B–1 15599 Sec.7 12/9/01 11:14 AM Page 237 PriStar Specifications Features and Benefits • Lightweight, corrosion-resistant, copper-free aluminum alloy (0.3% max. copper content). • All operating shafts are stainless steel for corrosion resistance. • Durable cast on lugs cannot get lost. • Ground screw is highly visible and accessible. • Uniform wall thickness (not ribbed) for versatility of conduit openings assuring 5 full threads engagement and maximum available area for conduit drilling and tapping. • Operators may be mounted through back wall for panel mounting. • Box depth provides for the stacking of 2 contact blocks. • Anodized aluminum operators install easily in the field. Certifications/Compliances E53505 LISTED Certified LR36172 * *CSA certified products require guarded pilot devices. Class I, Groups C&D Class II, Groups E, F, G Class III For NEMA 4 or special machining options, see XIFC Series in Section 5. Table A2 Control Station Boxes Number of Operators Surface Mount Panel Mount Std. Cond. Size (inches) 1 2 3 4 5 6 7 8 12 15 18 X1 X2 X3 X4 X5 X6 X7 X8 X12 X15 X18 X1P X2P X3P X4P X5P X6P X7P X8P X12P X15P X18P 3/4 3/4 3/4 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 Applicable Standard Underwriters Laboratories: UL 698, CSA C22.2 No. 30. Surface Mount: Operators mounted in cover Panel Mount: Operators mounted in back Note: All operator holes are 3/4"-14 NPSM Table B2 Pilot Lights & Lighted Pushbutton Lens Color Amber Blue Clear Green Red White Suffix Nos. for Std. Pilot Lt. Candelabra Base 1000 Hr. Lamp 60 61 62 63 64 65 Suffix Nos. for Guarded Pilot Lt. Candelabra Base 337 338 339 340 341 342 Suffix Nos. for Pilot Lt. Slide Base 5000 Hr. Lamp 66 67 68 69 70 71 Suffix Nos. for Guarded Pilot Lt. Slide Base Suffix Nos. for Lighted Pushbutton 343 344 345 346 347 348 30 35 40 45 50 55 237 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 238 7B–2 PriStar Box & Suffix Numbers Table C2 Selector & Key Switch Suffix Numbers Selector Switch Suffix Numbers Contact Block/Cam Included Contact Sequence Standard Sel. Switch Sel. Switch w/ Padlock Spring Ret. Center from R & L Key Switch Suffix Numbers Spring Ret. Center from R Spring Ret. Center from L Standard Key Switch Spring Ret. Center from R & L Spring Ret. Center from R Spring Ret. Center from L BT1A/1 NO NC XO OX 6 283 82 BT1B/1 NC NO OX XO 7 284 83 BT2/1 NO NO OX OX 8 285 84 BT3/1 NC NC XO XO 9 286 85 BT2/3 NO NO XOO OOX 10 293 111 135 159 86 229 249 269 BT1B/2 NC NO XOX XXO 11 288 112 136 160 87 224 244 264 BT2/2 NO NO XOX OOX 12 289 113 137 161 88 225 245 265 BT3/2 NC NC OXO XXO 13 290 114 138 162 89 226 246 266 BT3/3 NC NC OXX XXO 14 294 115 139 163 90 230 250 270 BT1A/2 NO NC OXO OOX 15 287 116 140 164 91 223 243 263 BT1A/3 NO NC OXX OOX 16 291 117 141 165 92 227 247 267 BT1B/3 NC NO XOO XXO 17 292 118 142 166 93 228 248 268 Contact blocks and cam included with selector switch. O = Contact Open X = Contact Closed Table D2 Pushbutton Suffix Numbers BT1A BT2 BT3 BT4 BT5 Contact Configuration Momentary Pushbutton Momentary Pushbutton w/ Padlock 1NO/1NC 2NO 2NC 1NO 1NC 1 2 3 4 5 307 308 309 310 311 Mushroom Head Momentary Pushbutton 106 107 108 109 110 1 Dual Pushbutton Momentary 72 73 74 2 Dual Pushbutton w/ Lockout 322 323 324 2 Dual Pushbutton Maint. 77 78 79 2 Dual Pushbutton Maint. w/ Lock 2 327 329 329 Pushbuttons furnished with Black collars and knobs as standard. Optional knobs: Green, Red. Optional Collars: Blue, Green, Gold, Red or Aluminum (unpainted). 1 Standard knob is Red. Black or Green available. 2 Standard with one Green knob labeled “Start” and one Red knob labeled “Stop.” Unlabeled Black knobs available. Other pilot devices available – Consult Factory. 238 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7B–3 15599 Sec.7 12/9/01 11:14 AM Page 239 PriStar Dimensions 4 1/2" 4 5/16" BT 3 1/4" 1" A B 1 1/2" Dimensions Enclosure X1 X2 X3 X4 X5 X6 X7 X8 X12 X15 X18 Nom. Inside Dim. 030303 030603 030703 030903 031103 031303 031503 031803 032403 033003 033603 Dim. in Inches B A 4 1/2 7 8 10 12 14 16 19 25 31 37 5 1/2 8 9 11 13 15 17 20 26 32 38 Est. Weight (lbs.) 5 7 8 10 11 12 13 16 21 28 33 *Std. Conduit Size (inches) 3/4 3/4 3/4 1 1 1/4 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 Control Stations have conduit openings centered on top and bottom. *Consult factory for other conduit sizes. 239 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 240 7B–4 PriStar Ordering Information To Order To order control stations, determine the number of operators required. Select the control station box by operator quantity and mounting type from Table A2. Order operators by suffix numbers from Tables B2, C2 and D2. Add suffix numbers to box number and separate by dashes. All operator holes must be filled by an operator. Use suffix “0” for plugs to fill unused space. Installation of operators will be made from top to bottom in sequence as listed. Select optional legend plates from Table F2 below. Table F2 Legend Plate Standard Markings Pushbuttons/Pilot Lights Blank Start Inch Stop Run Forward Reverse Fast Slow Open Close Up Jog On Off Back Selector Switches Reset In Out Left Right Low High Down E-Stop Run-Jog Hand-Auto Forward-Reverse Fast-Slow Open-Close Up-Down Off-On Open-Off-Close Fast-Off-Slow Run-Auto-Jog Hand-Off-Auto Forward-Off-Reverse 1-Off-2 Up-Off-Down Legend plates are anodized aluminum with engraved letters on black background. Stop has red and start has green background. Special engraved legend plates can be supplied. Contact Ratings PriStar AC Volts Make & Interrupting Capacity A Normal Load Break A Continuous Current A 110 60 6.0 10 DC 220 30 3.0 10 440 15 1.5 10 550 12 1.2 10 120 1.1 1.1 10 240 0.5 0.5 10 600 0.2 0.2 10 240 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7C–1 15599 Sec.7 12/9/01 11:14 AM Page 241 Factory-Sealed Control Stations F B E C D A Dimensions Dimensions in Inches XFSA3223 XFSA3911 XFSA3185 A 4 1/4 Features and Benefits • Factory-sealed control stations eliminate the need for poured seals • All control stations have 3/4" feed-through conduit entries • Factory-sealed contact block rated NEMA A600 and NEMA Q300 • All selector switches have lock-out capabilities • Bodies and covers are cast from lightweight, corrosion-resistant, copper-free aluminum • High-quality legend plates permit easy identification of device function • Durable cast-on lugs cannot get lost B 8 C 4 11/16 D 2 5/8 E 7 1/8 F 11/32 Certifications/Compliances Cover Assembly Body Assembly Complete Enclosure Assembly Class I, Division 1, Groups B* CD Class I, Division 2, Groups BCD† Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB NEMA 4 Option: Class I, Division 1, Groups C & D Class I, Division 2, Groups BCD† Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB • Ground screw is highly visible and accessible • Strong, durable materials for reliability and safety • Customization of box entries available – please consult factory • NEMA 4 option available – please consult factory Class II, Division 1, Groups E, F & G Class II, Division 2, Groups E, F & G† Material/Finish NEMA 3, 3R, 4, 7CD, 9EFG, 12 Body, Cover: Copper-Free Aluminum Operator and Pilot Light Bodies: Anodized Aluminum Operator Shaft: Stainless Steel Levers: Aluminum Contact BlockOnly Class I, Division 1, Groups BCD (recognized) Class I, Division 2, Groups BCD (listed) Class I, Zone 1, Group IIB+H2 Class I, Zone 2, Group IIB+H2 Application A wide variety of control stations may be assembled from Adalet bodies, devices and covers for use indoor or outdoor where Class I or Class II hazards are present, such as petroleum refineries, chemical plants and grainprocessing and storage facilities. XFS Control Stations may be used in conjunction with magnetic starters or contactors for remote control of motors. Applicable Standard Underwriters Laboratories: UL 698, UL 1203 *Group B pending †Division 2 Compliance Catalog No. Control Station Description XFSA3101 Black momentary pushbutton XFSA3223 Start-stop momentary pushbuttons XFSA3911 Maintained emergency stop with mushroom head XFSA3173 2-position, 2-circuit selector switch with 1NO/1NC contact XFSA3185 2-position, 4-circuit selector switch with 2NO/2NC contacts XFSA3178 3-position, 2-circuit selector switch with 1NO/1NC contact marked HAND-OFF-AUTO XFSA31208 Green pilot light XFSA31209 Red pilot light XFSA32089 One green and one red pilot light XFSA30925 Red pilot light with start-stop momentary dual pushbutton 241 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 242 7C–2 OmniStar Specifications Features and Benefits • Factory sealed control station eliminates the need for poured seals • Factory sealed contact block rated NEMA A600 and NEMA Q300 • Single-station through four-gang vertical or horizontal configurations are available to accommodate a wide variety of system needs • Conduit entries available in 1/2", 3/4" and 1" sizes either dead-end or feed through • Customization possible by using any of a wide variety of devices: pilot lights, miniature operators, momentary contact pushbuttons, selector switches, key operator selector switches or rocker arm • One- through four-hole covers allow up to four NO/NC contact blocks per station • Bodies and covers are cast from lightweight, corrosion-resistant, copper-free aluminum • High-quality legend plates permit easy identification of device function • Durable cast-on lugs cannot get lost • Ground screw is highly visible and accessible • Strong, durable materials for reliability and safety • Customization of box entries available – please consult factory • NEMA 4 option available – please consult factory Material/Finish Body, Cover: Copper-Free Aluminum Operator and Pilot Light Bodies: Anodized Aluminum Operator Shaft: Stainless Steel Knobs: Nylon Application A wide variety of control stations may be assembled from Adalet bodies, devices and covers for use indoor or outdoor where Class I or Class II hazards are present, such as petroleum refineries, chemical plants and grain processing and storage facilities. XFS Control Stations may be used in conjunction with magnetic starters or contactors for remote control of motors. Certifications/Compliances XFSC Cover Assembly XFSB Body Assembly LISTED XFSA Complete Enclosure Assembly Class I, Division 1, Groups CD Class I, Division 2, Groups B*CD† Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB NEMA 4 Option: Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D† Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB Class II, Division 1, Groups E, F & G Class II, Division 2, Groups E, F & G† NEMA 3, 3R, 4, 7CD, 9EFG, 12 Contact Block Only LISTED Class I, Division 1, Groups BCD (recognized) Class I, Division 2, Groups BCD (listed) Class I, Zone 1, Group IIB+H2 Class I, Zone 2, Group IIB+H2 Applicable Standard Underwriters Laboratories: UL 698, UL 1203 *Group B Compliance †Division 2 Compliance 242 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7C–3 15599 Sec.7 12/9/01 11:14 AM Page 243 OmniStar Bodies & Covers Table A1 Conduit Entry A Hole Location Suffix Numbers Conduit Entry Catalog Suffix No. Top Bottom Left 1/2" 3/4" 1" 2 3 4 A A A B B B C 1 C C 1 Replacement Body Catalog No. Right 1 D 1 D D C XFSB2 XFSB3 XFSB4 D B 1 Catalog suffix number followed by hole location suffix (C&D holes always 1" NPT) Example – 3ACD would be a body with a 3/4" hole in the top position and two 1" holes on the sides. Note: When ordering assembled control station, catalog number should begin with XFSA to indicate body and cover. Refer to page 7D–6 for catalog logic/example. Table B1 Covers Style Catalog Suffix No. NEMA Type 4 Catalog Suffix No. Replacement Cover 2 Catalog No. NEMA Type 4 Replacement Cover 2 Catalog No. – 1 2 3 4 5 RA -N4 1-N4 2-N4 3-N4 4-N4 5-N4 RA-N4 XFSC XFSC-1 XFSC-2 XFSC-3 XFSC-4 XFSC-5 XFSC-N4 XFSC-1-N4 XFSC-2-N4 XFSC-3-N4 XFSC-4-N4 XFSC-5-N4 Blank One 3/4" NPSM Hole Two 3/4" NPSM Holes One 3/4" NPSM Hole and Two 3/8-16” UNC Holes Four 3/8-16" UNC Holes Two 3/8-16" UNC Holes Rocker Arm — See next page 2 Replacement cover catalog numbers should be followed by suffix numbers for Adalet operators. Example – XFSC-4-N4 would be a NEMA Type 4 cover with four holes. XFSC-1 XFSC-2 XFSC-4 XFSC-3 XFSC-5 243 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:14 AM Page 244 7C–4 OmniStar Device Kits – Pushbuttons & Pilot Lights Table C1 Pushbuttons Catalog Suffix Nos. for 1 NO/1 NC Kit Momentary Pushbutton – Black Momentary Pushbutton – Green Momentary Pushbutton – Red Momentary PB w/ Padlock – Black Momentary PB w/ Padlock – Green Momentary PB w/ Padlock – Red Mushrm Hd Momentary PB – Black Mushrm Hd Momentary PB – Green Mushrm Hd Momentary PB – Red Mushrm Hd Maintained Mushrm Hd Maintained Lighted Pushbutton – Amber2 Lighted Pushbutton – Blue2 Lighted Pushbutton – Clear2 Lighted Pushbutton – Red2 Lighted Pushbutton – White2 Dual PB Momentary – “Start/Stop” Dual PB Momentary – Green/Red Dual PB Momentary – Black/Black Dual PB w/ Lockout – “Start/Stop” Dual PB w/ Lockout – Green/Red Dual PB w/ Lockout – Black/Black Dual PB Maint – “Start/Stop” Dual PB Maint – Green/Red Dual PB Maint – Black/Black Dual PB Maint w/ Lockout – “Start/Stop” Dual PB Maint w/ Lockout – Green/Red Dual PB Maint w/ Lockout – Black/Black Rocker Arm 2 NO/2 NC1 Use Suffix “0” for 3/4" NPSM plug and Suffix “00” for 3/8" UNC plug to fill unused spaces. For collars different in color than pushbutton ordered, consult factory. Catalog Suffix Nos. for 2 NO/2 NC 1F 2F 3F 4F 5F 6F 7F 8F 9F 911F 10F 11F 12F 13F 14F 15F 16F 17F 18F 912F 1F 9F 25F 26F 27F 28F 29F 30F 31F 32F 34F 35F 36F 37F RA1 23F 25F 20F 21F 22F 23F 24F 1 For Rocker Arm 3 NO/3 NC, use suffix RA2 andfor Rocker Arm 4 NO/4 NC, use suffix RA3. 2 Not for use in NEMA 4 applications 61F Contact Ratings OmniStar AC Volts Make & Interrupting Capacity Normal Load Break Continuous Current Catalog No. FSBT A A A 110 60 6 10 220 30 3 10 DC 440 15 1.5 10 550 12 1.2 10 120 .55 .55 2.50 440 .27 .27 2.50 One Normally Open and One Normally Closed. Table D1 Pilot Lights Lens Color Suffix Nos. for Guarded Pilot Lt. Candelabra Base Suffix Nos. for Guarded Pilot Lt. Slide Base Suffix Nos. for Miniature Pilot Lights Amber Blue Clear Green Red White 205F 206F 207F 208F 209F 210F 215F 216F 217F 218F 219F 220F 201F 202F 203F 244 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7C–5 15599 Sec.7 12/9/01 11:14 AM Page 245 OmniStar Device Kits – Selector Switches Table E1 Selector Switches Selector Switch Cam Suffix Nos. for Mounting Position A 1 NO/1 NC 1 2 3 4 5 6 1 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 1 2 3 4 5 6 51F 52F 53F 54F 55F 56F 73F 74F 75F 76F 77F 78F 91F 92F 93F 94F 95F 106F 107F 108F 109F 110F 122F 123F 124F 125F 126F 138F 139F 140F 141F 142F 153F 154F 155F 156F 157F 168F 169F 170F 171F 172F 183F 184F 185F 186F 187F 188F Selector Switch Selector Switch Selector Switch Selector Switch Selector Switch Selector Switch Selector Switch with Padlock Selector Switch with Padlock Selector Switch with Padlock Selector Switch with Padlock Selector Switch with Padlock Selector Switch with Padlock Selector Switch with Spring Return Center Right to Left Selector Switch with Spring Return Center Right to Left Selector Switch with Spring Return Center Right to Left Selector Switch with Spring Return Center Right to Left Selector Switch with Spring Return Center Right to Left Selector Switch with Spring Return Center from Right Selector Switch with Spring Return Center from Right Selector Switch with Spring Return Center from Right Selector Switch with Spring Return Center from Right Selector Switch with Spring Return Center from Right Selector Switch with Spring Return Center from Left Selector Switch with Spring Return Center from Left Selector Switch with Spring Return Center from Left Selector Switch with Spring Return Center from Left Selector Switch with Spring Return Center from Left Key Selector Switch with Spring Return Center Right to Left Key Selector Switch with Spring Return Center Right to Left Key Selector Switch with Spring Return Center Right to Left Key Selector Switch with Spring Return Center Right to Left Key Selector Switch with Spring Return Center Right to Left Key Selector Switch with Spring Return Center from Right Key Selector Switch with Spring Return Center from Right Key Selector Switch with Spring Return Center from Right Key Selector Switch with Spring Return Center from Right Key Selector Switch with Spring Return Center from Right Key Selector Switch with Spring Return Center from Left Key Selector Switch with Spring Return Center from Left Key Selector Switch with Spring Return Center from Left Key Selector Switch with Spring Return Center from Left Key Selector Switch with Spring Return Center from Left Key Selector Switch Key Selector Switch Key Selector Switch Key Selector Switch Key Selector Switch Key Selector Switch Suffix Nos. for Suffix Nos. for Mounting Position B Mounting Position AB 1 NO/1 NC 2 NO/2 NC 61F 62F 63F 64F 65F 66F 79F 80F 81F 82F 83F 84F 96F 97F 98F 99F 100F 111F 112F 113F 114F 115F 127F 128F 129F 130F 131F 143F 144F 145F 146F 147F 158F 159F 160F 161F 162F 173F 174F 175F 176F 177F 189F 190F 191F 192F 193F 194F MOUNTING POSITION A Contact Sequence Chart 2-Position Selector Switches Cam 1 Contact Sequence O = Contact Open X = Contact Closed Circuit of Contact Block 67F 68F 69F 70F 71F 72F 85F 86F 87F 88F 89F 90F 101F 102F 103F 104F 105F 116F 117F 118F 119F 120F 132F 133F 134F 135F 136F 148F 149F 150F 151F 152F 163F 164F 165F 166F 167F 178F 179F 180F 181F 182F 195F 196F 197F 198F 199F 200F 3-Position Selector Switches Cam 2 Cam 3 Cam 4 Contact Contact Contact Sequence Sequence Sequence Cam 5 Cam 6 Contact Contact Sequence Sequence Mounting Position Normally Closed (NC) Normally Open (NO) A Normally Closed (NC) Normally Open (NO) B Circuit A Circuit B XO OX XX O OO X X XO OOX XOX OXO OOX X XO OOX OXO Circuit A Circuit B XO OX OX O XO X OXX X OO XOO OX X OXX X OO XOO OOX MOUNTING POSITION B VIEWED FROM BACK POSITIONS A AND B TO BE DETERMINED AT INSTALLATION 245 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:15 AM Page 246 7C–6 OmniStar Dimensions – Vertical & Horizontal 4-Gang Assembly L K J R B E Q F D A F P C B E HORIZONTAL 4-GANG ASSEMBLY C D A VERTICAL 4-GANG ASSEMBLY Dimensions Dimensions in Inches A 4 1/4 B 8 4 C D E F J K 11/16 2 5/8 7 1/8 11/32 7 5/16 14 5/8 L 21 15/16 P 9 1/8 Q R 18 1/4 27 3/8 246 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 7C–7 15599 Sec.7 12/9/01 11:15 AM Page 247 OmniStar Ordering Information To Order To order control stations, determine the number of operators required. Select the control station body and cover by operator quantity and mounting type from Tables A1 and B1. Order operators by suffix numbers from Tables C1, D1 and E1. Add suffix numbers to box/cover assembly number (replacing the “B” in the box catalog number with an “A” for “Assembly” followed by a number to indicate the number of holes in the cover), separating the assembly number from the suffix number(s) by dashes. All operator holes must be filled by an operator or plug. Installation of operators will be made in the following order: upper left, upper right, lower left, lower right. See Assembly Catalog Numbers Logic/Example below. Select legend plates from Table F1 below. Table F1 Legend Plate Standard Markings Pushbuttons/Pilot Lights Blank Start Inch Stop Run Forward Reverse Fast Slow Open Close Up Jog On Off Back Selector Switches Reset In Out Left Right Low High Down E-Stop Run-Jog Hand-Auto Forward-Reverse Fast-Slow Open-Close Up-Down Off-On Open-Off-Close Fast-Off-Slow Run-Auto-Jog Hand-Off-Auto Forward-Off-Reverse 1-Off-2 Up-Off-Down Legend Plates are anodized aluminum with engraved letters on black background. Stop has red and start has green background. Special engraved legend plates can be supplied. Assembly Catalog Numbers Logic/Example X F S BOX AND COVER ASSEMBLY A 2 3 4 A B C D CONDUIT HOLE SIZE *HOLE LOCATIONS IN BOX 1 2 3 4 5 RA – SUFFIX NUMBERS (FILLING HOLES UPPER LEFT, UPPER RIGHT, LOWER LEFT, LOWER RIGHT) XFSA2A1-1F is an assembled control station with one 1/2" hub, and one operator hole with one momentary pushbutton black. COVER *C & D holes are always supplied as 1" NPT 247 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.7 12/9/01 11:15 AM Page 248 Quick Reference Guide METHODS OF PROTECTION Area Division 1 Division 2 Area Zone 0 Zone 1 Zone 2 Protection Method UL CSA CENELEC Explosionproof Intrinsically Safe (2 Fault) Purge/Pressurized (Type X or Y) Nonincendive Non-sparking device Purge/Pressurized (Type Z) Hermetically sealed Any Class I, Division 1 Method Protection Method Intrinsically Safe 'ia' (2 Fault) Flameproof 'd' Increased Safety 'e' Intrinsically Safe 'ib' (1 Fault)0 Encapsulation 'm' Oil Immersion 'o' Purged/Pressurized 'p' Powder filling 'q' Any Zone 0 Method Non-sparking 'nA' Hermetically sealed 'nC' Nonincendive 'nC' Restricted breathing 'nR' Any Zone 0 or 1 Method ANSI/UL 1203 CSA-30 -- -- ANSI/UL 913 CSA-157 -- -- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 UL 1604 CSA-213 CSA-213 --- --- ANSI/NFPA 496 ANSI/NFPA 496 -- -- UL 1604 CSA-213 -- -- -- -- -- -- UL (AEx) CSA (Ex) CENELEC (EEx) IEC (Ex) UL 2279 Pt. 11 CSA-E79-18 EN 50028 IEC 60 079-18 UL 2279 Pt. 1 UL 2279 Pt. 7 CSA-E79-1 CSA-E79-7 EN 50018 EN 50019 IEC 60 079-1 IEC 60 079-7 UL 2279 Pt. 11 CSA-E79-11 EN 50020 IEC 60 079-11 UL 2279 Pt. 18 UL 2279 UL 2279 Pt. 2 UL 2279 -UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 UL 2279 Pt. 15 -- CSA-E79-18 CSA-E79-6 CSA-E79-2 CSA-E79-5 -CSA-E79-15 CSA-E79-15 CSA-E79-15 CSA-E79-15 -- EN 50028 EN 50015 EN 50016 EN 50017 -prEN 50021 prEN 50021 prEN 50021 prEN 50021 -- IEC 60 079-18 IEC 60 079-6 IEC 60 079-2 IEC 60 079-5 -IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 IEC 60 079-15 -- TEMPERATURE CLASSES AREA CLASSIFICATIONS Ignitable Materials Present Continuously Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Zone 0 (Zone 20 Dust) Zone 0 Division 1 Zone 1 (Zone 21 Dust) Zone 1 Division 1 Zone 2 (Zone 22 Dust) Zone 2 Division 2 IEC/CENELEC NEC 505 NEC 500 ATEX Classification by Group & Category According to Use Ignitable Materials Present Continuously Equipment Group II Category 1 Equipment (surface) Equipment Group I Category M1 Equipment (mining) IEC Ignitable Materials Present Intermittently Ignitable Materials Present Abnormally Category 2 Equipment Category 3 Equipment Category M2 Equipment — GAS GROUPINGS Gas, Dust or Fiber NEC 505/IEC/CENELEC NEC 500 Acetylene Hydrogen Ethylene Propane Methane Metal Dust Coal Dust Grain Dust Fibers Group IIC Group IIC/Group IIB+H2 Group IIB Group IIA Group I (firedamp) None None None None Class I/Group A Class I/Group B Class I/Group C Class I/Group D Class I/Group D Class II/Group E Class II/Group F Class II/Group G Class III ACRONYMS CENELEC - European Committee for Electrotechnical Standardization IEC - International Electrotechnical Commission NEC - National Electrical Code U.L. - Underwriters Laboratories C.S.A. - Canadian Standards Association FM - Factory Mutual BASEEFA - British Approvals Service for Electrical Apparatus in Flammable Atmospheres NFPA - National Fire Protection Agency ISO - International Organization for Standardization ANSI - American National Standard Institute ATEX - Atmospheres Explosibles Maximum Surface Temperature NEC 505 IEC CENELEC 450°C 300°C 280°C 260°C 230°C 215°C 200°C 180°C 165°C 160°C 135°C 120°C 100°C 85°C T1 T2 T3 T4 T5 T6 NEC 500 T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 INGRESS PROTECTION (IP XX) CODES # First Number (Protection against Solid Bodies) Second Number (Protection against Liquids) 0 1 2 3 4 5 6 7 8 No protection Objects greater than 50mm Objects greater than 12mm Objects greater than 2.5mm Object greater than 1mm Dust Protected Dust-tight --- No protection Vertically dripping water 75-90 Deg. dripping water Sprayed water Splashed water Water jets Heavy seas Effects of immersion Indefinite immersion 15599 Sec.8 12/9/01 11:17 AM Page 249 Circuit Breaker Lighting & Power Distribution Panel Boards Explosionproof and Dust-Ignitionproof 8A–1 ENCLOSURES: The housings are copper-free cast aluminum alloy. The housings are Adalet XCE series and have precision ground cover and body joints. The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges, stainless steel cover bolts and are provided with Nema 4 gasketing. All covers are removable for clear access to breakers and gutter space. The compact design of rectangular housings permits close grouping on switch racks and other structures. No additional space is required for cover removal except from the front. MECHANICAL FEATURES: The front mounted power panel and lighting panel branch breaker handles can be padlocked either in “off” or “on” position. All breaker handles are spring loaded allowing closing of the cover with breaker toggle in any position. Operating handle shafts have “V” ring gaskets for watertight application. ELECTRICAL FEATURES: Breaker panel chassis, featuring bolt-on circuit breakers, are made by Cutler-Hammer. Chassis for the power distribution XPB2 series provides 480V/277 volt connections. The circuit breakers are rated for 480 volt max. The Adalet lighting panel board XPB1 series offers 15 through 60 amps, 120, 240 volt bolt on circuit breakers with ground and insulated neutral bars as standard features. The Cutler-Hammer Industrial Ground Fault Circuit Protectors (GFCI 5mA, GFEPD 30mA) and switching neutral breakers are available as optional features. Compliances: Approvals: UL, cUL Classified Enclosure UL Standard 1203 CSA Standard C22.2 No. 30 Enclosure Certifications Class I, Groups B, C, D Class II, Groups E, F, G Class III NEMA 4, 7, 9 E81696 249 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 250 Circuit Breaker Lighting Panel Boards Explosionproof and Dust-Ignitionproof CLASS I, GROUP B, C, D; CLASS II, GROUPS E, F & G; CLASS III, NEMA 4, 7 & 9 8A–2 Explosionproof circuit breaker lighting panelboards use cast aluminum alloy housings with hinged cover. External operating handles can be padlocked in “on” or “off” position. Incorporates Cutler-Hammer bolt-on breakers @ 240 volt max. Top feed standard. BACK FED MAIN BREAKER PANELBOARDS 120/240 VOLT, 1 PHASE 3 WIRE, SOLID NEUTRAL CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES 10,000 AMPERE INTERRUPTING CAPACITY (SYM.) Number of Avail. Breakers MLO / BFD Catalog Number Main Breaker Amperes Box Size 10 BFD XPB1-121 B1 100 A 16 BFD XPB1-181 B1 100 A 22 BFD XPB1-241 B1 100 B BACK FED MAIN BREAKER PANELBOARDS 120/208 VOLT, 3 PHASE 4 WIRE, SOLID NEUTRAL CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES 10,000 AMPERE INTERRUPTING CAPACITY (SYM.) Number of Avail. Breakers Catalog Number MLO / BFD Main Breaker Amperes Box Size 9 BFD XPB1-123 B1 100 A 15 BFD XPB1-183 B1 100 A 21 BFD XPB1-243 B1 100 B 250 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 251 Circuit Breaker Lighting Panel Boards Explosionproof and Dust-Ignitionproof 8A–3 MAIN LUG ONLY PANELBOARDS 1 PHASE 3 WIRE 120/240 VOLT TOP FEED MAIN LUG ONLY CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES 10,000 AMPERE INTERRUPTING CAPACITY (SYM) Number of Breakers Catalog Number Main Lug Amperes Box Size 12 XPB1-121L1 100 A 18 XPB1-181L1 100 A 24 XPB1-241L1 100 B 24 XPB1-241L2 225 B 30 XPB1-301L2 225 D 36 XPB1-361L2 225 D MAIN LUG ONLY PANELBOARDS 3 PHASE 4 WIRE 120/208 VOLT TOP FEED MAIN LUG ONLY CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES 10,000 AMPERE INTERRUPTING CAPACITY (SYM) Number of Breakers Catalog Number Main Lug Amperes Box Size 12 XPB1-123L1 100 A 18 XPB1-183L1 100 A 24 XPB1-243L1 100 B 24 XPB1-243L2 225 B 30 XPB1-303L2 225 D 36 XPB1-363L2 225 D How to order: A) Specify catalog number and voltage B) Number of operator handles, single pole, two pole and three pole as required. C) Circuit breakers, number of poles and ampere rating. Unused spaces will be plugged. Top feed standard. 251 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 252 Circuit Breaker Lighting Panel Boards Explosionproof and Dust-Ignitionproof MODIFICATIONS AND OPTIONS 8A–4 Branch Breakers – Operating Handles – Components CIRCUIT BREAKER OPERATOR HANDLES INSTALLED IN XPB1 PANEL BOARDS Catalog Number Weight Each Description XPB1-H1 For single pole BAB breakers 1/4 lb. XPB1-H2 For two pole BAB breakers 1/4 lb. XPB1-H3 For three pole BAB breakers 1/4 lb. XPB1-GL For single pole GFI ground 1/4 lb. XPB1-GR Fault breakers (specify left or right side) 1/4 lb. BRANCH CIRCUIT BREAKERS INSTALLED IN XPB1 PANEL BOARDS: BOLT-ON THERMAL MAGNETIC BREAKERS 120/240 VOLT 10,000 AMPERE I.C. Catalog No. Description XPB1-1* 1 pole breaker (available in 10-70 amp) XPB1-2* 2 pole breaker (available in 10-100 amp) XPB1-3* 3 pole breaker (available in 10-100 amp) *Add ampere rating of the branch breaker when ordering. GROUND FAULT CIRCUIT PROTECTORS 120/240 VOLT 10,000 AMPERE I.C. STD. 22,000 AMPERE I.C. OPTIONAL BOLT-ON SWITCHING NEUTRAL BREAKERS 120/240 VOLT 10,000 AMPERE I.C. Catalog No. Description Catalog No. Description XPB1-1GFCI* 1 pole GFCI Breaker 5 MA Sensitivity XPB1-N1* 1 pole switching to neutral Requires two spaces (available in 15-30 amp) 2 pole switching to neutral Requires three spaces (available in 15-30 amp) XPB1-2GFCI* 2 pole GFCI Breaker 5 MA Sensitivity XPB1-1GFEPD* 1 pole GFCI Breaker 30 MA Sensitivity XPB1-2GFEPD* 2 pole GFCI Breaker 30 MA Sensitivity XPB1-N2* *Add ampere rating of the branch breaker when ordering Above Available with special application Bell Alarm or Auxiliary Switch. *Add ampere rating of the branch breaker when ordering OPTIONAL FEATURES MODIFICATIONS: Suffix Letter E EE L1 L2 NP CU Q Description Breather Drain (not type 4) Breather and drain (not type 4) Epoxy Coating Outside Epoxy Coating Inside/Outside Lamacoid Nameplate Copper Bus Bar Quad-Lead Bolts 252 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 253 Circuit Breaker Power Distribution Panel Boards Explosionproof and Dust-Ignitionproof Explosionproof circuit breaker power panelboards use cast aluminum alloy housings with hinged cover. External operating handles can be padlocked in “on” or “off” positions. Incorporates Cutler-Hammer bolt-on breakers @ 480 volt max. Top feed standard. BACK FED MAIN BREAKER PANELBOARDS 277/480 VOLT, 3 PHASE 4 WIRE, SOLID NEUTRAL CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES 14,000 AMPERE INTERRUPTING CAPACITY (SYM.) Number of Avail. Breakers MLO / BFD Catalog Number Main Breaker Amperes Box Size 9 BFD XPB2-123B1 100 A 15 BFD XPB2-183B1 100 A 21 BFD XPB2-243B1 100 B 100 ampere main lugs conductor size #12 -1/0 CU/AL. 225 ampere main lugs conductor size #6-300 MCM CU/AL. How to order: A) Specify catalog number and voltage B) Number of operator handles, single pole, two pole and three pole as required. C) Circuit breakers, number of poles and ampere rating Unused spaces will be plugged. Top feed standard. MAIN LUG ONLY PANELBOARDS 277/480 VOLT, 3 PHASE 4 WIRE CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES 14,000 AMPERES INTERRUPTING CAPACITY (SYM) Compliances: UL, cUL Classified Enclosure UL Standard 1203 CSA Standard C22.2 No. 30 Class I, Groups B, C, D Class II, Groups E, F, G NEMA 4, 7, 9 Number of Breakers Catalog Number Main Lug Amperes Box Size 12 XPB2-123L1 100 A 18 XPB2-183L1 100 A 24 XPB2-243L1 100 B 24 XPB2-243L2 225 B Approvals: 30 XPB2-303L2 225 D Enclosure Certifications 36 XPB2-363L2 225 D How to order: Specify catalog number, operator handles and circuit breakers as separate items. Single pole breakers use 1 handle space, 1 handle. 2 pole, 2 spaces, 1 handle. 3 pole, 3 spaces, 1 handle. Unused spaces will be plugged. Top feed standard. E81696 253 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 8A–5 CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; CLASS II, NEMA 4, 7 & 9 15599 Sec.8 12/9/01 11:17 AM Page 254 Circuit Breaker Power Distribution Panel Boards Explosionproof and Dust-Ignitionproof MODIFICATIONS AND OPTIONS 8A–6 Branch Breakers – Operating Handles – Components BREAKER OPERATOR HANDLES INSTALLED IN XPB2 PANEL BOARDS Catalog Number XPB2-H1 Description Weight Each For 1, 2 or 3-pole GHB breaker 1/4 lb. BRANCH CIRCUIT BREAKERS INSTALLED IN XPB2 PANEL BOARDS: BOLT-ON THERMAL MAGNETIC BREAKERS Catalog No. XPB2-1* Description 1 pole GHB breaker (available in 15-100 amp) 277 volt A.C. 2 pole GHB breaker (available in 15-100 amp) 480 volt A.C. 3 pole GHB breaker (available in 15-100 amp) 480 volt A.C. XPB2-2* XPB2-3* *Add ampere rating of the branch breaker when ordering. OPTIONAL FEATURES MODIFICATIONS: Suffix Letter E EE L1 L2 NP CU Q Description Breather Drain (not type 4) Breather and drain (not type 4) Epoxy Coating Outside Epoxy Coating Inside/Outside Lamacoid Nameplate Copper Bus Bar Quad-Lead Bolts 254 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 255 Circuit Breaker Lighting and Distribution Panel Boards Explosionproof and Dust-Ignitionproof ENCLOSURE DIMENSIONS & DATA SHEET A B 1/2" NPT Top (1) — (1) — Side — (2) — Bottom (1) (8) — — — Top (1) — (1) — — (2) — — Bottom (1) (8) — — Top (1) — — (1) Side — (2) — — Bottom (1) (10) — — (1) Top (1) — — Side — (2) — — Bottom (1) (10) — — D (C) Overall Width 3" NPT Side C (B) Mtg Height Conduit Entries 1" NPT 2" NPT Box Size Internal Dimensions (A) Mtg Width (D) Overall Height (E) Overall Depth A 161606 19 3/4 11 20 7/8 20 7/8 11 5/8 B 162406 19 3/4 18 3/8 20 7/8 28 7/8 11 1/2 5/8 C 162806 19 3/4 22 1/2 20 1/2 32 1/2 10 3/4 5/8 D 163406 19 3/4 27 20 1/2 38 1/2 10 3/4 5/8 8A–7 CONDUIT ENTRIES Enclosure Size Mtg. Bolt Size Box Size F G H J K L M N Weight lbs. A 1 1/4 3 3/4 4 3/4 2 3/8 3 5/8 1 3 1/2 2 1/2 160 B 1 1/4 3 3/4 4 3/4 2 3/8 3 5/8 3 5 2 1/2 220 C 2 4 4 15/16 2 15/16 4 3/16 5 7 2 1/2 235 D 2 4 4 15/16 2 15/16 4 3/16 8 11 2 1/2 285 255 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 256 Motor Control Explosionproof Circuit Breakers - Disconnect Switches 8B–1 EXPLOSIONPROOF AND DUST-IGNITIONPROOF CLASS I, GROUPS B, C & D: CLASS II, GROUPS E, F & G; NEMA 7 & 9 BREAKERS: Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 1200 amperes. Also available as non-automatic circuit interrupters, without automatic overload trip elements for load switching and isolation. In this application short circuit and overload protection must be provided by separate protection device. Breakers also available for magnetic trip only. The units can be set up for GE, Cutler-Hammer (Westinghouse), Square-D and ITE (Siemens) brand circuit breakers. Consult factory for other brands. Holes for CutlerHammer circuit breakers are drilled directly into back wall. ENCLOSURES: The housings are copper-free cast aluminum alloy. The enclosures are Adalet XCE series with precision ground cover and body joints. The enclosure design offers sufficient space for wire bending and ease of installation and maintenance. XCBC and larger units are furnished with hinges, and stainless steel cover bolts. The covers are removable for clear access to breakers. For XCBA and XCBB units, hinge and mounting pan are optional. The front mounted circuit breaker handle is padlockable in either “on” or “off” position. Optional XCBH 2-2 handle shown; standard handle is XBO. High interrupting capacity breakers are also available in comparable size. Approvals: Enclosure Certifications E81696 Compliances: Class I, Groups B, C, D Class II, Groups E, F, G NEMA 4, 7, 9 UL Classified Enclosure Optional XCBH Style “Classic”, larger handle. Special 1" – 11 1/2" NPSM opening required for installation. Enclosure Standard XBO Style “New”, spring loaded, compact adjustable design, ease of assembly and less expensive. Standard 3/4 – 14 NPSM opening required for installation. UL Classified Enclosure Rating XCBA, XCBB, XCBC, XCBD, XCBE, XCBF, XCBG Class 1, Grps BCD XCBA N4, XCBB N4, XCBC N4, XCBD N4, XCBE N4, XCBF N4, XCBGN4 Class 1, Grps CD 256 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 257 Motor Control Explosionproof Circuit Breakers - Disconnect Switches Molded Case Circuit Breaker Enclosures (Breaker Included) Breaker Frame Interrupting Size Rating Catalog No. Volts 14,000 100/150 3 Pole Rating Non-Interchangeable Non-Interchangeable 15 XCBA-N4-15E42* XCBA-N4-15E43* 20 XCBA-N4-20E42* XCBA-N4-20E43* 30 XCBA-N4-30E42* XCBA-N4-30E43* 40 XCBA-N4-40E42* XCBA-N4-40E43* 50 XCBA-N4-50E42* XCBA-N4-50E43* 480 60 XCBA-N4-60E42* XCBA-N4-60E43* Interrupting Volt AC 70 XCBA-N4-70E42* XCBA-N4-70E43* Capacity 250 80 XCBB-N4-80E42* XCBB-N4-80E43* at 480 Volt DC 90 XCBB-N4-90E42* XCBB-N4-90E43* 100 XCBB-N4-100E42* XCBB-N4-100E43* 110 XCBB-N4-110E42* XCBB-N4-110E43* 125 XCBB-N4-125E42* XCBB-N4-125E43* 150 XCBB-N4-150E42* XCBB-N4-150E43* 15 XCBA-N4-15E62* XCBA-N4-15E63* 20 XCBA-N4-20E62* XCBA-N4-20E63* 30 XCBA-N4-30E62* XCBA-N4-30E63* 40 XCBA-N4-40E62* XCBA-N4-40E63* 14,000 Amperes 600 50 XCBA-N4-50E62* XCBA-N4-50E63* Interrupting Volt AC 60 XCBA-N4-60E62* XCBA-N4-60E63* Capacity 250 70 XCBA-N4-70E62* XCBA-N4-70E63* at 600 Volt DC 80 XCBB-N4-80E62* XCBB-N4-80E63* 90 XCBB-N4-90E62* XCBB-N4-90E63* 100 XCBB-N4-100E62* XCBB-N4-100E63* 110 XCBB-N4-110E62* XCBB-N4-110E63* 125 XCBB-N4-125E62* XCBB-N4-125E63* 150 XCBB-N4-150E62* XCBB-N4-150E63* 70 XCBC-N4-70JN2* XCBC-N4-70JN3* 90 XCBC-N4-90JN2* XCBC-N4-90JN3* Volt AC 18,000 225/250 2 Pole Amperes Volt AC 100/150 Catalog No. Amp Amperes 600 100 XCBC-N4-100JN2* XCBC-N4-100JN3* Interrupting Volt AC 125 XCBC-N4-125JN2* XCBC-N4-125JN3* Capacity 250 150 XCBC-N4-150JN2* XCBC-N4-150JN3* at 600 Volt DC 175 XCBC-N4-175JN2* XCBC-N4-175JN3* 200 XCBC-N4-200JN2* XCBC-N4-200JN3* 225 XCBC-N4-225JN2* XCBC-N4-225JN3* 250 XCBC-N4-250JN2* XCBC-N4-250JN3* Volt AC * Circuit breaker brand suffix: W-Cutler-Hammer (Westinghouse) G-General Electric S-Square-D 8B–2 Breaker T-I.T.E. (Siemens) 257 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 258 Motor Control Explosionproof Circuit Breakers - Disconnect Switches Molded Case Circuit Breaker Enclosures (Breaker Included) Breaker Breaker Frame Interrupting Catalog No. Size Rating Volts 8B–3 22,000 400 3 Pole Rating Non-Interchangeable Non-Interchangeable 100 XCBD-N4-100KN2* XCBD-N4-100KN3* 125 XCBD-N4-125KN2* XCBD-N4-125KN3* 150 XCBD-N4-150KN2* XCBD-N4-150KN3* 600 175 XCBD-N4-175KN2* XCBD-N4-175KN3* Interrupting Volt AC 200 XCBD-N4-200KN2* XCBD-N4-200KN3* Capacity 250 225 XCBD-N4-225KN2* XCBD-N4-225KN3* at 600 Volt DC 250 XCBE-N4-250KN2* XCBE-N4-250KN3* 300 XCBE-N4-300KN2* XCBE-N4-300KN3* 350 XCBE-N4-350KN2* XCBE-N4-350KN3* 400 XCBE-N4-400KN2* XCBE-N4-400KN3* 22,000 250 XCBE-N4-250LI2* XCBE-N4-250LI3* Amperes 600 300 XCBE-N4-300LI2* XCBE-N4-300LI3* Interrupting Volt AC 350 XCBE-N4-350LI2* XCBE-N4-350LI3* Capacity 250 400 XCBE-N4-400LI2* XCBE-N4-400LI3* at 600 Volt DC 500 XCBF-N4-500LI2* XCBF-N4-500LI3* 600 XCBF-N4-600LI2* XCBF-N4-600LI3* Volt AC 800 2 Pole Amperes Volt AC 600 Catalog No. Amp 22,000 600 400 XCBF-N4-400MI2* XCBF-N4-400MI3* Amperes Volt AC 500 XCBF-N4-500MI2* XCBF-N4-500MI3* Interrupting 250 600 XCBF-N4-600MI2* XCBF-N4-600MI3* Capacity Volt AC 700 XCBF-N4-700MI2* XCBF-N4-700MI3* 800 XCBF-N4-800MI2* XCBF-N4-800MI3* at 600 Volt AC Note: For Interchangeable Trip substitute an “I” for “N” in the Catalog Number. (Example: XCBC-N4-70JI2) Fusible Disconnect Switches Horsepower Horsepower Rating Rating Amp Catalog No. at 480 Volts at 600 Volts Rating 3 Pole 20 20 30 XCBA-N4-30DF3* 40 50 60 XCBA-N4-60DF3* 75 75 100 XCBB-N4-100DF3* 125 150 200 XCBC-N4-200DF3* Note: (3) Class “J” fuses are optional in the above catalog numbers. * Circuit breaker brand suffix: W-Cutler-Hammer (Westinghouse) G-General Electric S-Square-D T-I.T.E. (Siemens) 258 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 259 Motor Control Explosionproof Circuit Breakers - Disconnect Switches Non-Fused Disconnect Switches Horsepower Rating Rating Amp at 480 Volts at 600 Volts Rating Catalog No. 3 Pole 20 25 30 XCBA-N4-30DN3 40 60 60 XCBA-N4-60DN3 75 75 100 XCBB-N4-100DN3 125 150 200 XCBC-N4-200DN3 8B–4 Horsepower Circuit Breaker Enclosure Only Breaker Frame Size Trip Range Catalog Number 100 15-70 XCBA-N4 100/150 80-150 XCBB-N4 225/250 70-250 XCBC-N4 400 100-225 XCBD-N4 400/600 250-400 XCBE-N4 600/800 400-800 XCBF-N4 1200 800-1200 XCBG-N4 CIRCUIT BREAKERS and DISCONNECT OPTIONS Description Suffix Auxiliary Switch 1A and 1B Contacts Auxiliary Switch 2A and 2B Contacts Bell Alarm (Specify No. of Contacts) Breather/Drain - installed in bottom Breather and Drain installed High Interrupting Capacity Breaker Epoxy Coating (External), (Specify Color) Epoxy Coating (Internal and External), (Specify Color) Substitute MCP for Breaker Phenolic Nameplate (Specify Legend) Shunt Trip (Specify Voltage Rating) Undervoltage Release (Specify Voltage Rating) Other / Special AS1 AS2 BA E EE HI LI L2 M NP ST UV Z Available On Circuit Disconnect Breaker Switch • • • • • • • • • • • • • Universal Enclosure Only • • • • • • • • • • • • • Data Dimensions Enclosure Width Nominal Inside Overall Mounting Mounting Conduit Dimensions Dimensions CL to CL Bolt Dimension Length Depth A B C E Conduit Shipping # of Holes Weight F Size D G Size Top/Bottom Pounds XCBA-N4 6 11 5 9 1/4 14 1/4 9 9 1/8 7 1/2 7/16 2 1/2 — 1 1/4 1 28 XCBB-N4 6 13 5 9 1/4 16 1/4 9 9 1/8 9 1/2 3/8 2 1/2 — 2 1 31 XCBC-N4 7 18 5 10 3/8 21 5/8 9 9 3/4 14 1/2 3/8 2 3/4 — 2 1/2 1 47 XCBD-N4 12 20 5 16 1/4 24 1/4 10 15 3/4 14 3/8 1/2 3 1/4 2 1/2 1 108 XCBE-N4 12 24 6 16 1/4 28 1/4 11 15 3/4 18 3/8 1/2 3 5/8 — 2 7/8 3 2 131 XCBF-N4 12 36 8 16 1/4 40 1/4 13 1/2 15 3/4 29 5/8 4 1/2 3 3/8 4 2 237 XCBG-N4 12 46 8 16 1/4 50 1/4 13 3/8 15 3/4 39 5/8 4 1/2 3 3/8 4 2 286 All enclosures have 1/2" NPT top and bottom for breather drain. 259 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 260 Motor Control Explosionproof Motor Starters Features: 8C–1 • Lightweight, corrosion resistant, copper-free aluminum alloy (0.3% max. copper content). • Uniform wall thickness (not ribbed) for versatility of conduit openings assuring 5 full thread engagement and maximum available area for conduit drilling and tapping. • Captive stainless steel cover bolts resist corrosion and cannot get lost. • Ground lug is highly visible and accessible. • Bolted flange design provides clear access to internal components. • Rugged cast aluminum handle allows locking in “on” or “off” position with as many as three padlocks. • Clevis assembly allows closing of door with breaker handle assembly in any position without damage to breaker and without internal mounting hardware. • All operating shafts are stainless steel for corrosion resistance. • Durable cast-on lugs cannot get lost. • Backpan accommodates most popular brands of circuit breaker and motor circuit protectors and motor starters. • Two predrilled and tapped operator holes furnished with explosionproof plugs for field installation of pilot devices. • Two additional optional holes available. • Aluminum hinges with stainless steel hinge pins are “liftoff” so the cover can be easily removed. XCBSLQN4 • Easily adjustable reset button allows for starter changes in the field. • N4 gasket furnished as standard on combination starters. • Narrow design on combination starter through size 2 allows closer spacing on switchracks while providing ample room to mount control transformer on the backpan. • XCBSAQ and XCBSBQ provided with XBO breaker handle as standard. Compliances: • NEC: Class I, Groups B, C, D Class II, Groups E, F, G Class III Certifications • UL Standard 1203 Hazardous (Classified) Locations C CLASSIFIED E81696 CERTIFIED LR 36172 • CSA Standard C22.2 No. 30 • NEMA: 3, 3R, 4, 7BCD, 9EFG, 12 Note: Consult Factory for approvals and certifications on specific enclosures. 260 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 261 Motor Control Explosionproof Motor Starters 8C–2 Universal Enclosures Only (does not include breaker or starter) Class I, Groups C and D; Class II, Groups E, F & G; Class III, Type 3, 3R, 4,7CD, 9EFG, 12 Class I, Groups C and D; Class II, Groups E, F & G; Class III, Type 7CD, 9EFG Type 4 For two-speed, Y-Delta, reduced voltage, or multiple starter packages consult factory for availability. 261 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 262 Motor Control Explosionproof Motor Starters Combination Starter Enclosures (includes breaker and starter) Full voltage non-reversing 8C–3 262 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 263 Motor Control Explosionproof Motor Starters 8C–4 Combination Starter Enclosures (includes breaker and starter) Full voltage reversing Magnetic Full Voltage Starter Enclosures (includes starter) 263 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 264 Motor Control Explosionproof Motor Starters Options, Dimensions and Ordering Instructions 8C–5 Description Suffix Combination Starter Start/Stop Dual Pushbutton (1NO Start, 1NC Stop) A Green Start Pushbutton (1NO) A1 Red Stop Pushbutton (1NC) A2 Red Stop Pushbutton, Mushroom Head (1NC) A3 Black Pushbutton (1NO, 1NC) A4 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Auxiliary Switch on Breaker (1A and 1B Contacts) AS1 Auxiliary Switch on Breaker (2A and 2B Contacts) AS2 Hand-Off-Auto Selector Switch B Selector Switch (2-Position) (1NO, 1NC) B1 Bell Alarm Switch on Breaker (Specify No. of Contacts) BA Pilot Light 120 Volt AC (•See Color Table) C1* Pilot Light with Guard 120 Volt AC (•See Color Table) CG1* Push-to-Test Light 120 Volt AC (1NO, 1NC) (•See Color Table) CP1*† Breather/Drain Installed in Bottom E$ Breather and Drain Installed EE$ Auxiliary Contacts on Starter (+NO, -NC) (Specify No. of Contacts) G (+ -) Time Delay Relay-On Delay (Specify Range) H1 Time Delay Relay-Off Delay (Specify Range) H2 8-Point Terminal Strip K Epoxy Coating External Only (Specify Color) L1 Epoxy Coating External and Internal (Specify Color) L2 Lamacoid Nameplate (Specify Legend) NP Overload Heaters (Specify Full Load Amps) OL Control Relay (Description Required) R Space Heater (Specify Wattage) S Shunt Trip on Breaker (Specify Voltage) ST 50 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block†† T1F 100 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block†† T2F 150 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block†† T3F 200 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block†† T4F 250 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block†† T5F 300 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block†† T6F Other Control Transformer (Specify VA, Pri. And Sec.) T7 Undervoltage Release on Breaker (Specify Voltage Rating) UV Internal Control Wiring W Other (Specify) Z *Color Table R-Red G-Green A-Amber B-Blue Available On Non-Combination Starter Universal Enclosure Only • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • C-Clear • W-White † Not available in Group B applications †† Fuses Included $ for Group B applications add H to the suffix 264 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 265 Motor Control Explosionproof Motor Starters DIMENSIONS Nominal Dimensions In Inches A B C D E 11 1/8 Est. F G Ship. Wt. Cond. Size $ *XCBSAQ-N4 062305 4 1/8 25 1/2 26 15/16 9 11/16 2 1/2 3&5 61 1 1/2 $ *XCBSBQ-N4 072706 4 3/4 29 7/8 11 13/16 31 1/8 10 1/2 2 13/16 3&5 87 1 1/2 18 3/8 16 15/16 XCBSLQ-N4 122408 15 3/4 XCBSMQ-N4 123608 15 3/4 28 1/4 12 15/16 3 3&5 160 2 29 16 15/16 40 1/4 13 3/8 3 5/8 3&5 260 2 1/2 XCBSN-N4 164610 XCMRSG-N4 121808 19 3/4 39 21 3/4 50 7/8 16 7/16 4 7/8 3&5 420 4 15 3/4 14 1/8 17 22 1/4 12 5/8 2 13/16 3&6 100 1 1/4 XCMRSK-N4 XCMRSP-N4 122406 15 3/4 18 3/8 17 28 1/4 10 15/16 3 5/16 3&5 130 2 183608 21 3/4 29 23 3/4 40 7/8 14 3/4 4 1/8 3&5 395 2 †XMSB 081006 10 3/4 6 1/2 12 13 3/8 8 1/4 2 3/8 3&6 36 1 †XMSD 101406 13 10 5/8 14 17 3/8 8 3/8 2 3/4 3&6 55 1 1/2 †XMSH 121808 15 3/4 14 1/8 17 22 1/4 10 3/4 3 1/2 3&6 105 2 1/2 †XMSQ 183610 21 3/4 29 23 3/4 40 7/8 14 7/8 4 5/16 3&6 380 3 $ *† XMRSC 101406 10 5/8 13 18 13 3/8 8 3/8 2 1/4 3&5 55 1 $ *† XMRSF 121206 8 5/8 15 3/4 17 16 1/4 8 15/16 3 3&6 85 1 1/2 $ *† XMRSO 181808 13 21 3/4 23 3/4 22 7/16 12 7/16 3 7/8 3&6 190 2 1/2 Standard conduit openings at locations 1 and 2, control circuit opening 3/4” NPT at locations shown in column “G”. Each housing has one 1/2” NPT top & bottom for breather and drain. * Mounting feet on top and bottom. † No breaker handle furnished. $ Use view “B” for mounting dimensions. 265 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 8C–6 Enclosure Nom. Inside Dim. 15599 Sec.8 12/9/01 11:17 AM Page 266 Explosionproof Enclosures & Components - IEC Motor Control 8D–1 Explosionproof enclosures suitable for housing IEC (International Electrotechnical Commission) style motor starters and combination starters. Sizes from 8” x 8” x 4” up to 12” x 18” x 6”. Design options include: pushbutton and switch operators, pilot lights, push-to-test lights, breather/drains, auxiliary contacts, Lamacold™ nameplates, and control transformers with fuse blocks. Enclosures are classified by UL/cUL as to explosion and fire hazards. Compliances: Class I, Groups C, D Class II, Groups E, F, G Type 4 IEC Motor Starters - Starters Included IEC Combination Motor Starters - Components Included For ABB Components For ABB Components Catalog Number Enclosure Size Amp Rating HP at 480 Volts Catalog Number Enclosure Size Amp Rating HP at 480 Volts XSIAA9 XSIAA11 XDIAA17 XSIAA25 XSICA28 XSICA32 XSICA41 XSICA54 XSIDA65 XSIDA80 XSIEA110 XCE 080804 XCE 080804 XCE 080804 XCE 080806 XCE 101006 XCE 101006 XCE 101006 XCE 101006 XCE 101206 XCE 101206 XCE 1014D6 9 11 17 25 28 32 41 54 65 80 110 5 7.5 10 15 20 25 30 40 50 60 75 XCIAA9 XCIAA11 XCIAA17 XCIAA25 XCIAA28 XCIAA32 XCIAA41 XCIAA54 XCIAA65 XCIBB80 XCIBB110 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 121806 XCE 121806 9 11 17 25 28 32 41 54 65 80 110 5 7.5 10 15 20 25 30 40 50 60 75 For Cutler-Hammer Components XSIAH10 XSIAH12 XSIAH18 XSIAH25 XSICH32 XSICH37 XSICH44 XSICH60 XSIDH73 XCE XCE XCE XCE XCE XCE XCE XCE XCE 080804 080804 080804 080804 101006 101006 101006 101006 101206 For Cutler-Hammer Components 9 12 18 25 32 37 44 60 73 5 7.5 10 15 20 25 30 40 50 9 12 17 25 28 32 40 50 65 80 95 5 7.5 10 15 20 25 30 40 50 60 75 9 12 18 25 32 37 40 50 65 80 5 7.5 10 15 20 25 30 40 50 60 XCIAH10 XCIAH12 XCIAH18 XCIAH25 XCIAH32 XCIAH37 XCIAH44 XCIAH60 XCIAH73 For Siemens Components XSIAS9 XSIAS12 XSIAS17 XSIAS25 XSICS28 XSICS32 XSICS40 XSICS50 XSIDS65 XSIDS80 XSIDS95 XCE XCE XCE XCE XCE XCE XCE XCE XCE XCE XCE 080804 080804 080804 080804 101006 101006 101006 101006 101206 101206 101206 266 XCE XCE XCE XCE XCE XCE XCE XCE XCE XCE 080804 080804 080804 080806 080806 101006 101006 101006 101206 101206 1014D6 1014D6 1014D6 1014D6 1014D6 1014D6 1014D6 1014D6 1014D6 10 12 18 25 32 37 44 50 73 5 7.5 10 15 20 25 30 40 50 9 12 17 25 28 32 40 50 65 80 95 5 7.5 10 15 20 25 30 40 50 60 75 9 12 18 25 32 37 40 50 65 80 5 7.5 10 15 20 25 30 40 50 60 For Siemens Components XCIAS9 XCIAS12 XCIAS17 XCIAS25 XCIAS28 XCIAS32 XCIAS40 XCIAS50 XCIBS65 XCIBS80 XCIBS95 For Square D Components XSIAD9 XSIAD12 XSIAD18 XSIBD25 XSIBD32 XSICD37 XSICD40 XSICD50 XSIDD65 XSIDD80 XCE XCE XCE XCE XCE XCE XCE XCE XCE XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 121806 XCE 121806 XCE 121806 For Square D Components XCIAD9 XCIAD12 XCIAD18 XCIAD25 XCIAD32 XCIAD37 XCIAD40 XCIAD50 XCIAD65 XCIBD80 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 1014D6 XCE 121806 For Group B applications, consult factory ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 267 Explosionproof Enclosures & Components - IEC Motor Control IEC Motor Starters Enclosures only IEC Combination Motor Starters Enclosures only Catalog Number Enclosure Size For ABB Components Amp Rating HP at 480 Volts Catalog Number Enclosure Size Amp Rating HP at 480 Volts XSIAA XSIAA XSIAA XSIAA XCE XCE XCE XCE 080804 080804 080804 080804 9 11 17 25 5 7.5 10 15 XCIAA XCIAA XCIAA XCIAA XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 9 11 17 25 5 7.5 10 15 XSICA XSICA XSICA XSICA XCE XCE XCE XCE 101006 101006 101006 101006 28 32 41 54 20 25 30 40 XCIAA XCIAA XCIAA XCIAA XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 28 32 41 54 20 25 30 40 XSIDA XSIDA XSIEA XCE 101206 XCE 101206 XCE 1014D6 65 80 110 50 60 75 XCIAA XCIBB XCIBB XCE 1014D6 XCE 121806 XCE 121806 65 80 110 50 60 75 For Cutler-Hammer Components 8D–2 For ABB Components For Cutler-Hammer Components XSIAH XSIAH XSIAH XSIAH XCE XCE XCE XCE 080804 080804 080804 080804 10 12 18 25 5 7.5 10 15 XCIAH XCIAH XCIAH XCIAH XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 10 12 18 25 5 7.5 10 15 XSICH XSICH XSICH XSICH XSIDH XCE XCE XCE XCE XCE 101006 101006 101006 101006 101206 32 37 44 60 73 20 25 30 40 50 XCIAH XCIAH XCIAH XCIAH XCIAH XCE XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 1014D6 32 37 44 60 73 20 25 30 40 50 For Siemens Components For Siemens Components XSIAS XSIAS XSIAS XSIAS XCE XCE XCE XCE 080804 080804 080804 080804 9 12 17 25 5 7.5 10 15 XCIAS XCIAS XCIAS XCIAS XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 9 12 17 25 5 7.5 10 15 XSICS XSICS XSICS XSICS XCE XCE XCE XCE 101006 101006 101006 101006 28 32 40 50 20 25 30 40 XCIAS XCIAS XCIAS XCIAS XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 28 32 40 50 20 25 30 40 XSIDS XSIDS XSIDS XCE 101206 XCE 101206 XCE 101206 65 80 95 50 60 75 XCIBS XCIBS XCIBS XCE 121806 XCE 121806 XCE 121806 65 80 95 50 60 75 For Square D Components For Square D Components XSIAD XSIAD XSIAD XSIBD XCE XCE XCE XCE 080804 080804 080804 080806 9 12 18 25 5 7.5 10 15 XCIAD XCIAD XCIAD XCIAD XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 9 12 18 25 5 7.5 10 15 XSIBD XSICD XSICD XSICD XCE XCE XCE XCE 080806 101006 101006 101006 32 37 40 50 20 25 30 40 XCIAD XCIAD XCIAD XCIAD XCE XCE XCE XCE 1014D6 1014D6 1014D6 1014D6 32 37 40 50 20 25 30 40 XSIDD XSIDD XCE 101206 XCE 101206 65 80 50 60 XCIAD XCIBD XCE 1014D6 XCE 121806 65 80 50 60 267 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 268 Explosionproof Enclosures & Components - IEC Motor Control Diagram Specifications Starters Diagram Catalog No. Base Enclosure XCE A Overall B C MTG E MTG F MTG BOLT 080804 080806 101006 101206 1014D6 11.38 11.38 13.38 13.38 13.38 11.38 11.38 13.38 15.38 17.38 7.75 9.75 9.62 10.25 9.75 4.25 4.25 6.5 8.5 10.62 11 11 13 13.25 13.25 3/8 3/8 3/8 3/8 3/8 2.81 3.81 3.88 4.13 2.88 2.25 2.25 2.50 2.5 2.5 1-1/2 1-1/2 2 2 2 26 30 46 48 51 13.38 16.25 17.38 22.25 9.75 10.12 10.62 14.12 13.25 15.75 3/8 1/2 2.88 4.00 3.0 3.0 1-1/2 2 51 95 Conduit Location Conduit D G Size Weight Starters 8D–3 XSIA XSIB XSIC XSID XSIE Combinations XCIA XCIB 1014D6 121806 Options Suffix Combination Starter Available On Non-Combination Starter Start/Stop Dual Pushbutton (1NO Start, 1NC Stop) A • • • Green Start Pushbutton (1NO) A1 • • • Red Stop Pushbutton (1NC) A2 • • • Red Stop Pushbutton, Mushroom Head (1NC) A3 • • • Black Pushbutton (1NO, 1NC) A4 • • • Hand-Off-Auto Selector Switch B • • • Selector Switch (2-Position) (1NO, 1NC) B1 • • • Pilot Light 120 Volt AC (*See Color Table) C1* • • • Pilot Light with Guard 120 Volt AC (*See Color Table) CG1* • • • Push-to-Test Light 120 Volt AC (1NO, 1NC) (*See Color Table) CP1*† • • • E • • • EE • • • G(+ -) • • Lamacold Nameplate (Specify Legend) NP • • 50 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block T1F • • 100 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block T2F • • 150 VA Control Transformer 480V Pri, 120 V Sec. W/Fuse Block T3F • • 200 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block T4F • • Description Combination Diagram Breather/Drain Installed in Bottom Breather and Drain Installed Auxiliary Contacts on Starter (+NO,-NC) (Specify No. of Contacts) Universal Enclosure Only • *Color Table R-Red G-Green A-Amber B-Blue C-Clear W-White †Not available in Group B applications 268 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 269 Motor Control Explosionproof Motor Starters MANUAL MOTOR STARTERS Catalog Number Number of Hubs Conduit Size Poles Mfg. Bolt Size Weight (lbs.) XLSC21 †* 2 1/2 1 1/4" 2 3/4 XLSC22 †* 2 1/2 2 1/4" 2 3/4 XLSC31 †* 2 3/4 1 1/4" 2 3/4 XLSC32 †* 2 3/4 2 1/4" 2 3/4 XLSC2 ** 2 1/2 - 1/4" 2 3/4 XLSC3 ** 2 3/4 - 1/4" 2 3/4 8E–1 Type XLS Manual Motor Starting Switches are furnished complete with switch and interchangeable heaters. The XLS housings are cast aluminum alloy and have a trouble free operating lever threaded through the cover. † = HP Rating * = Heater Table MAXIMUM HORSEPOWER RATINGS †Adalet Symbol 1B 2B 1C 2C Make & Catalog No. Westinghouse MST01 Westinghouse MST02 GE CR101Y GE CR101H Poles 1 2 1 2 115-230 Volts AC 1 H.P. 1 H.P. 1 H.P. 1 H.P. 32 Volts DC 1/4 H.P. 1/4 H.P. 115 Volts DC 1/4 H.P. 1 H.P. 1 H.P. 1 H.P. 230 Volts DC 1/4 H.P. 1 H.P. 1/4 H.P 1 H.P. The following tables list interchangeable Heater elements for each manufacturer. The elements are not interchangeable between manufacturers. The heater elements listed are for motors rated 40°C continuous. For motors rated 50°C or 55°C, multiply by 0.9 and use this value to select heaters. WESTINGHOUSE *Adalet Symbol 1 2 3 4 5 6 7 8 9 10 11 12 13 Motor Full Load Current .40 - .43 .44- -.48 .49 - .53 .54 - .58 .59 - .64 .65 - .71 .72 - .78 .79 - .87 .88 - .95 .96 – 1.03 1.04 – 1.15 1.16 – 1.27 1.28 – 1.35 *Adalet Symbol 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 .48 .53 .58 .65 .71 .78 .86 .95 1.04 1.14 1.25 1.37 1.49 1.63 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Motor Full Load Current 1.36 – 1.51 1.52 – 1.67 1.68 – 1.83 1.84 – 1.99 2.00 – 2.23 2.24 – 2.47 2.48 – 2.71 2.72 – 2.95 2.96 – 3.27 3.28 – 3.59 3.60 – 3.99 4.00 – 4.39 4.40 – 4.79 *Adalet Symbol 27 28 29 30 31 32 33 34 35 36 37 38 39 Motor Full Load Current 4.80 – 5.26 5.27 – 5.83 5.84 – 6.39 6.40 – 7.03 7.04 – 7.74 7.75 – 8.46 8.47 – 9.35 9.36 – 10.30 10.31 – 11.35 11.36 – 12.47 12.48 – 13.67 13.68 – 15.12 15.13 – 16.00 29 30 31 32 33 34 35 36 37 38 39 40 41 5.90 6.41 6.98 7.60 8.25 8.95 9.75 10.60 11.40 12.50 13.60 14.80 16.00 How To Order: To determine the complete catalog number, select the unit wanted and add the Adalet symbol numbers for the make of starter wanted and the heaters required. Select heaters from charts. ** Enclosure less switch - for CSA certified switches rated 600V max, 30 amp max, 15HP max. GE 1.78 1.95 2.13 2.32 2.53 2.76 3.01 3.27 3.56 3.88 4.22 4.60 5.00 5.43 Certifications Class I, Groups C & D Class II, Groups E, F & G LR36172 269 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.8 12/9/01 11:17 AM Page 270 Motor Control Explosionproof Motor Starter/Protector 8E–2 Compliances: • NEC: Class I, Groups C, D Class II, Groups E, F, G • UL Standard 1203 Hazardous (Classified) Locations • CSA Standard 22.2 • NEMA: 7CD, 9EFG Approvals: • UL Classified Class I, Groups C, D Class II, Groups E, F, G • CSA Certified Class I, Groups C, D Class II, Groups E, F, G 270 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 271 Explosionproof Pilot Devices CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G APPLICATIONS 9A–1 Adalet operators are for use in control circuits functioning in environments containing hazardous gases, vapors or dusts. These heavy duty pilot lights, pushbuttons and selector switches are suitable for use in Class I, Groups B, C & D hazardous gas; Class II, Groups E, F & G dust atmospheres. Most are suitable for weather-tight (N4) applications. FEATURES: • Most operators are suitable for NEMA 3, 4, NEMA 7, 9, raintight, water-tight in hazardous environments. • Two lengths available for either surface or panel mount. • Knurled caps are standard with black anodized finish. • Optional: specify color-coding of operator caps (no additional cost). • Pilot light transformers available for 240 volts. • Special length pilot light wiring leads available. • Screw terminals available suffix T. • Coated to minimize corrosion and provide for ease of installation. • Operators are 3/4” NPSM standard. • Stainless steel shafts are standard (except pilot light pushbutton operator). Consult factory for UL/CSA certification availability. Compliances: NEC Class I, Groups B, C & D - Class II, Groups E, F, G UL Standard 698 - Standard C22.2 No. 30 Notes: Where reference is made to Class I and Class II hazardous locations, the equipment is suitable for use in both Division 1 and Division 2 hazardous locations. The Adalet engineering department is available to assist in the selection of custom explosionproof housings for your products. 271 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 272 Explosionproof and Dust-tight Pilot Lights CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Explosionproof pilot lights are suitable for panel or surface mount applications. All pilot lights are of sealed construction and can be relamped from the front by removal of lens cap. All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible leads, other lengths on special order, or screw terminals. All lens caps are black anodized aluminum finish. For color coding we will furnish at no additional charge the following color combinations: lens ambercap gold, lens blue-cap blue, lens clear-cap natural aluminum, lens green-cap green, lens red-cap red, lens white-cap natural aluminum. Specify on orders. 9A–2 Maximum installation thickness 1 15/16” on Long Series, 3/4” on Short Series. This standard series of pilot lights is equipped with candelabra base receptacles and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24, 30, 50, 75 and 135 volt lamps. Specify voltage desired. Catalog Number Long Series Catalog Number Short Series Weight Each Pounds Description XLA XLSA Amber Lens 1/2 XLB XLSB Blue Lens 1/2 1/2 XLC XLSC Clear Lens XLG XLSG Green Lens 1/2 XLR XLSR Red Lens 1/2 XLW XLSW White Lens 1/2 *Add suffix T to P/N for screw terminal This special series of pilot lights is equipped with slide base receptacles and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12, 24, 48 and 60 volt lamps. Specify voltage desired. Legend Plates, see page 9A–18 Catalog Number Long Series Catalog Number Short Series Description Weight Each Pounds XLAS XLSAS Amber Lens 1/2 XLBS XLSBS Blue Lens 1/2 XLCS XLSCS Clear Lens 1/2 XLGS XLSGS Green Lens 1/2 XLRS XLSRS Red Lens 1/2 XLSWS White Lens 1/2 XLWS *Add suffix T to P/N for screw terminal 2 5/16 Pilot Light Transformers Catalog Number Description Weight Each Pounds XLT 240 240 to 120 volt, 6VA 1 One transformer required for each pilot light. Adapter furnished for mounting on threaded pilot light stem, or can be mounted to housing as space requires. 272 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 273 Explosionproof and Dust-tight Pilot Lights CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Guarded Pilot Lights Maximum installation thickness 1 15/16” on Long Series (Panel Mount), 3/4” on Short Series (Surface Mount). This standard series of pilot lights is equipped with candelabra base receptacles and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24, 30, 50, 75 and 135 volt lamps. Specify voltage desired. Catalog No. Panel Mount (Long Series) Catalog No. Surface Mount (Short Series) Weight Each Pounds Description XLA-G XLSA-G Amber Lens 1/2 XLB-G XLSB-G Blue Lens 1/2 XLC-G XLSC-G Clear Lens 1/2 XLG-G XLSG-G Green Lens 1/2 XLR-G XLSR-G Red Lens 1/2 XLW-G XLSW-G White Lens 1/2 *Add suffix T to P/N for screw terminal This special series of pilot lights is equipped with slide base receptacles and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12, 24, 48 and 60 volt lamps. Specify voltage desired. Catalog No. Panel Mount (Long Series) Catalog No. Surface Mount (Short Series) Weight Each Pounds Description XLAS-G XLSAS-G Amber Lens 1/2 XLBS-G XLSBS-G Blue Lens 1/2 1/2 XLCS-G XLSCS-G Clear Lens XLGS-G XLSGS-G Green Lens 1/2 XLRS-G XLSRS-G Red Lens 1/2 XLWS-G XLSWS-G White Lens 1/2 *Add suffix T to P/N for screw terminal Replacement Guarded Lens Cap Assembly Catalog Number Description Weight Each Pounds XLA-GC Amber Lens 1/8 XLB-GC Blue Lens 1/8 XLC-GC Clear Lens 1/8 XLG-GC Green Lens 1/8 XLR-GC Red Lens 1/8 XLW-GC White Lens 1/8 Legend Plates, see page 9A-19. ADALET Enclosure Systems • Designing Our Products Around Yours SM 273 T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 9A–3 Explosionproof pilot lights are suitable for panel or surface mount applications. All pilot lights are of sealed construction and can be relamped from the front by removal of lens cap. All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible leads, other lengths on special order, or screw terminals. All lens caps are black anodized aluminum finish. 15599 Sec.9 12/9/01 11:19 AM Page 274 Explosionproof and Dust-tight Pilot Lights CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Guarded Pilot LED Lights LED Advantages: • 10 Year/100,000 hour service life under normal ambient conditions. • 1x to 4x more energy efficient. • Improved resistance to shock and vibration. • LEDs operate significantly cooler than traditional lamps. • Ultra bright cluster LED’s 9A–4 Explosionproof pilot LED lights are suitable for panel or surface mount applications. All candelabra base LED lights can be relamped from the front by removal of the lens cap. All pilot LED lights are made with 3/4” NPSM threads. All pilot LED lights have 8” flexible leads, other lengths on special order, or screw terminal. Screw terminal available suffix T. All lens caps are black anodized aluminum finish with clear glass lens. Maximum installation thickness: 1-15/16” on Panel Mount (Long Series), 3/4” on Surface Mount (Short Series). Consult Adalet for the availability of other voltages. Catalog No. Panel Mount (Long Series) Catalog No. Surface Mount (Short Series) Description Weight Each Pounds XLRL-G XLSRL-G Red 1/2 XLAL-G XLSAL-G Amber 1/2 XLGL-G XLSGL-G Green 1/2 XLWL-G XLSWL-G White 1/2 XLBL-G XLSBL-G Blue 1/2 *Add suffix T to P/N for screw terminal 274 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 275 Explosionproof and Dust-tight Pilot Light Push Buttons CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 7, 9 Indicator Light/Push Button Push-To-Test Operators For use with series BT contact blocks Description of operators only 9A–5 All operators are die cast aluminum alloy. The barrels are all 3/4” NPSM thread. Maximum installation thickness 1 15/16” panel mount, 3/4” surface mount. Furnished standard with 120 volt slide base lamp. Also available for 6, 12, 24, 28, 48 and 60 volts. Specify when ordering. For use with BT contact blocks. Contact blocks can be stacked for multiple circuits. Contact blocks are not included with the operators. Order from page 9A–20. For NEMA 4 application, add boot and special legend plate, see page 9A–19. Weight Each Pounds For Panel Mounting XLPA Amber Lens 3/4 XLPB Blue Lens 3/4 XLPC Clear Lens 3/4 XLPG Green Lens 3/4 XLPR Red Lens 3/4 White Lens 3/4 XLPW For Surface Mounting XLPAS Amber Lens 1/2 XLPBS Blue Lens 1/2 XLPCS Clear Lens 1/2 XLPGS Green Lens 1/2 XLPRS Red Lens 1/2 XLPWS White Lens 1/2 Legend Plates, see page 9A–19. 275 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 276 Explosionproof and Dust-tight Push Buttons CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Push Button Operators 9A–6 All operators are die cast aluminum alloy. The barrels are all 3/4” NPSM thread. Maximum installation thickness 1 3/4” panel mount, 3/4” surface mount. All operators have black molded nylon buttons. The exposed metal parts are black anodized aluminum. For color coding we will furnish at no additional cost the following color combinations: Red buttons with red metal caps and green buttons with green metal caps. Metal caps are also available in blue, gold or clear with black buttons. Specify colors required. Red Mushroom head buttons are 1 3/4” diameter anodized aluminum. Also available in black or green. XHPBPL has padlock attachment on top of cap allowing operator to be locked with the push button depressed. For use with BT contact blocks. Contact blocks can be stacked for multiple circuits. Contact blocks are not included with the operators. Order from page 9A–20. XHPPM/XHPPMS require 2" minimum spacing. For use with series BT contact blocks Description of operators only Weight Each Pounds XHPB Panel Mount 1/2 XHPBS Surface Mount 1/2 XHPBM Red Mushroom Head, Panel Mount 1/2 XHPBMS Red Mushroom Head, Surface Mount 1/2 XHPBPL W/Padlock devices, Panel Mount 3/4 XHPBSPL W/Padlock devices, Surface Mount 3/4 XHPPM* Push/Pull switches, Panel Mount 3/4 XHPPMS* Push/Pull switches, Surface Mount 3/4 Legend Plates, see page 9A–19. *Type BT1 contact blocks are included For extremely wet-dirty location applications, XHPB and XHPBS series are available to be used with protective boots, see page 9A–19. 276 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 277 Explosionproof and Dust-tight Push Buttons CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Push Button Operators 1 1 —4 5 1— 16 1 1 4 —2 3 —4 3 1 —4 3 1 —4 13 1 3— 16 5— 16 Cost effective modular operator body. The barrels are all 3/4” NPSM thread aluminum. Maximum installation thickness 1 3/4” panel mount, 3/4” surface mount. All operators have black molded nylon buttons. The exposed metal parts are black anodized aluminum. For color coding we will furnish at no additional cost the following color combinations: Red buttons with red metal caps and green buttons with green metal caps. Metal caps are also available in blue, gold or clear with black buttons. Specify colors required. Red Mushroom head buttons are 1 3/4” diameter anodized aluminum. Also available in black or green. XVHPBPL has padlock attachment on top of cap allowing operator to be locked with the push button depressed. For use with BT contact blocks. Contact blocks can be stacked for multiple circuits. Contact blocks are not included with the operators. Order from page 9A–20. XVHPPM/XVHPPMS require 2" minimum spacing. For use with series BT contact blocks 3 1 —4 3 1 —4 3 7 EXT. 5 —4 EXT. Description of operators only 9A–7 1 1 —4 Weight Each Pounds XVHPB Panel Mount 1/2 XVHPBS Surface Mount 1/2 XVHPBM Red Mushroom Head, Panel Mount 1/2 XVHPBMS Red Mushroom Head, Surface Mount 1/2 XVHPBPL W/Padlock devices, Panel Mount 3/4 XVHPBSPL W/Padlock devices, Surface Mount 3/4 XVHPPM* Push/Pull switches, Panel Mount 3/4 XVHPPMS* Push/Pull switches, Surface Mount 3/4 Legend Plates, see page 9A–19. *Type BT1 contact blocks are included 5 1 —8 5 1 —8 1 5— 16 For extremely wet-dirty location applications, XVHPB and XVHPBS series are available to be used with protective boots, see page 9A–19. 13 3— 16 277 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 278 Explosionproof and Dust-tight Push Buttons CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Dual Push Button Operator or Maintained Contact Unit All operators are die cast aluminum alloy. The barrels are all 3/4” NPSM thread. Maximum installation thickness 1 15/16” panel mount, 3/4” surface mount. For use with BT contact blocks. Contact blocks can be stacked for multiple circuits. Contact blocks are not included with XHD operators. Order from page 9A–20. 5 9A–8 1 —8 1 1 —4 5 1 —8 For use with series BT contact blocks 1 1 —4 1 1 —4 1 1 —4 3 3 4— 16 Description of operators only Weight Each Pounds XHDPB Panel Mount - momentary* 1/2 XHDPBS Surface Mount - momentary* 1/2 XHDMC Maintained Contact, Panel Mount 1/2 XHDMCS Maintained Contact, Surface Mount 1/2 *Two contacts in the BT contact block are actuated independently Furnished with one contact block XHMCD Description of operators only Weight Each Pounds Maintained Contact Unit 1 Two Push Buttons, Panel Mount 1 1 —4 1 3 1 —4 1 1 —4 1 —4 1 1 —4 XHMCSD 1 3 1 —4 1 —4 Maintained Contact Unit 1 Two Push Buttons, Surface Mount 1 1 —4 XHMCMD Maintained Contact Unit 1 Two Push Buttons, Panel Mount With one mushroom and one standard button XHMCMSD Maintained Contact Unit 1 Two Push Buttons, Surface Mount With one mushroom and one standard button Group CD Only The XHMCD and XHMCSD maintained contact units require only one contact block. These units consist of two operators and require two mounting positions. Legend Plates, see page 9A–19. 278 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 279 Explosionproof and Dust-tight Selector Switches CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Selector Switch Operators For use with series BT contact blocks Description of operators only 9A–9 All operators are die cast aluminum alloy. The barrels are all 3/4” NPSM thread. Maximum installation thickness: 1 15/16” panel mount, 3/4” surface mount. Selector switch operators can be used as 2 position or 3 position by removal of knob and rotating knob 180°. The actuator cam which operates the plungers on the contact blocks can be readily changed for various contact sequences. FOR 3 POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks are not included with XHSS operators. Select contact block and sequence operating cam from contact block page 9A–20. All operators have black molded nylon knobs. The exposed metal parts are black anodized aluminum. Metal caps are also available in blue, gold, clear, red or green with black knobs. Specify colors required. Weight Each Pounds XHSS Panel Mount 1/2 XHSSS Surface Mount 1/2 XHSC Spring Return to Center 1/2 from Right and Left Panel Mount XHSSC Spring Return to Center 1/2 XHSR XHSSR 3 POSITION ONLY from Right and Left Surface Mount Spring Return to Center 1/2 from Right, Maintain Left Panel Mount Spring Return to Center 1/2 from Right, Maintain Left Surface Mount XHSL Spring Return to Center 1/2 from Left, Maintain Right Panel Mount XHSSL Spring Return to Center 1/2 from Left, Maintain Right Surface Mount XHSSPL W/padlock device Panel Mount 3/4 XHSSSPL W/padlock device Surface Mount 3/4 XSSL-4P Panel Mount, Four Position 3/4 Selector Switch XSSL-5P Switch Included Panel Mount, Five Position 3/4 Selector Switch XSSS-4P Surface Mount, Four Position 3/4 Selector Switch XSSS-5P Surface Mount, Five Position 3/4 Selector Switch For extremely wet-dirty location applications, use Protective Boots Page 9A–19. EXCLUDES PADLOCK DEVICES. Legend Plates, see page 9A–19. 279 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 280 Explosionproof and Dust-tight Selector Switches CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Selector Switch Operators 9A–10 Cost effective modular operator body. The barrels are all 3/4” NPSM thread aluminum. Maximum installation thickness: 1 15/16” panel mount, 3/4” surface mount. Selector switch operators can be used as 2 position or 3 position by removal and rotation of the cam actuator. The cam which operates the plungers on the contact blocks can be changed for various contact sequences. FOR 3 POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks are not included with XVHSS operators. Select contact block and sequence operating cam from contact block page 9A–20. All operators have black molded nylon knobs. The exposed metal parts are black anodized aluminum. Metal caps are also available in blue, gold, clear, red or green with black knobs. Specify colors required. For use with series BT contact blocks Description of operators only Weight Each Pounds XVHSS Panel Mount 1/2 XVHSSS Surface Mount 1/2 XVHSSPL W/padlock device Panel Mount 3/4 XVHSSSPL W/padlock device Surface Mount 3/4 Legend Plates, see page 9A–19. For extremely wet-dirty location applications, use Protective Boots Page 9A–19. EXCLUDES PADLOCK DEVICES. The selector switch for Series BT blocks have a sequence actuating cam as an integral part of the operator. THE CAM NUMBER MUST BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT ARRANGEMENT CHARTS, SEE PAGE 9A–20. 280 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 281 Explosionproof and Dust-tight Selector Switches CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Keylock Selector Switch Operators Key removable one position only For use with series BT contact blocks Description of operators only Weight Each Pounds XHKSS Key Lock Operation 1/2 9A–11 All operators are die cast aluminum alloy. The barrels are all 3/4” NPSM thread. Maximum installation thickness: 1 15/16” panel mount, 3/4” surface mount. Selector switch operators can be used as 2 position or 3 position by removal of knob and rotating knob 180°. The actuator cam which operates the plungers on the contact blocks can be readily changed for various contact sequences. FOR 3 POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks are not included with operators. Select contact block and sequence operating cam from contact block page 9A–20. The exposed metal parts are black anodized aluminum. specify right, center or left Panel Mount XHKSSS Key Lock Operation 1/2 Surface Mount XHKSC Spring Return to Center 1/2 from Right and Left Panel Mount XHKSSC Spring Return to Center 1/2 from Right and Left XHKSSR 3 POSITION ONLY Surface Mount XHKSR Spring Return to Center 1/2 from Right, Maintain Left Panel Mount Spring Return to Center 1/2 from Right, Maintain Left Surface Mount XHKSL Spring Return to Center 1/2 from Left, Maintain Right Panel Mount XHKSSL Spring Return to Center 1/2 from Left, Maintain Right Surface Mount Legend Plates, see page 9A–19. The selector switch for Series BT blocks have a sequence actuating cam as an integral part of the operator. THE CAM NUMBER MUST BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT ARRANGEMENT CHARTS, SEE PAGE 9A–20. 281 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 282 Explosionproof and Dust-tight Selector Switches CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Keylock Selector Switch Operators 9A–12 Cost effective modular operator body. The barrels are all 3/4” NPSM thread aluminum. Maximum installation thickness: 1 15/16” panel mount, 3/4” surface mount. Selector switch operators can be used as 2 position or 3 position by removal and rotation of the cam actuator. The cam which operates the plungers on the contact blocks can be changed for various contact sequences. FOR 3 POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks are not included with operators. Select contact block and sequence operating cam from contact block page 9A–20. The exposed metal parts are black anodized aluminum. XVHKSS XVHKSSS Key removable one position only For use with series BT contact blocks Description of operators only Weight Each Pounds XVHKSS Key Lock Operation, 1/2 Panel Mount specify right, center or left XVHKSSS Key Lock Operation, 1/2 Surface Mount Legend Plates, see page 9A–19. The selector switch for Series BT blocks have a sequence actuating cam as an integral part of the operator. THE CAM NUMBER MUST BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT ARRANGEMENT CHARTS, SEE PAGE 9A–20. 282 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 283 Explosionproof Potentiometer and Switch Operators CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Potentiometer and Switch Operators Operators are die cast aluminum alloy. The barrels are all 3/4” NPSM thread. 1/4” diameter shafts. Maximum installation thickness: 1 15/16” panel mount, 3/4” surface mount. XPO-XPOS have knob and dial marked 1 to 100. Two dial sizes are available. XPOC-XPOCS have 15 turn counting dial. Operators include 3 pc. coupling and device mounting bracket. Weight Each Pounds Description XPO Plain Dial, Panel Mount 1/2 XPOS Plain Dial, Surface Mount 1/2 1/2 XPOL Plain Dial, Large Size, Panel Mount XPOSL Plain Dial, Large Size, Surface Mount 1/2 XPOC Counting Dial, Panel Mount 3/4 XPOCS Counting Dial, Surface Mount 3/4 9A–13 Catalog No. POTENTIOMETER NOT FURNISHED — Consult Factory. CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 7, 9 Manual and Motor Operated Rotating Shafts XCS manual operated shafts suitable for potentiometers, rheostats and other devices requiring external adjustment. Includes 3 piece coupling to compensate for misalignment. XCF motor operated shafts suitable for tachometers and rotating equipment with speeds to 5000 rpm. Shaft is ball bearing mounted. Includes flexible coupling to compensate for misalignment. Dimension in Inches Cat. No. Shaft Dia. A B C D E (NPSM) XCS-1 1/8 6 2 1/2 1 2 1/2 3/4-14 XCS-2 1/4 6 2 1/2 1 2 1/2 3/4-14 XCS-3 5/16 6 2 1/2 1 2 1/2 3/4-14 XCS-4 3/8 6 2 1/2 1 2 1/2 3/4-14 XCS-5 1/2 6 2 1/2 1 2 1/2 3/4-14 XCF-1 1/8 6 2 3/16 1 5/8 2 3/16 1/2-14 XCF-2 1/4 6 2 1/8 1 3/4 2 1/8 3/4-14 XCF-3 5/16 6 2 2 2 1-11 1/2 XCF-4 3/8 6 2 2 2 1-11 1/2 XCF-5 1/2 6 2 2 2 1 1/4-11 1/2 NOTE: NEMA 3, 4 Features Available for XCF Only 283 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 284 Explosionproof Potentiometer and Switch Operators CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Potentiometer Operators Cost effective modular operator body. The barrels are all 3/4” NPSM thread aluminum. 1/4” diameter shafts. Maximum installation thickness: 1 15/16” panel mount, 3/4” surface mount. XVPO-XVPOS have knob and dial marked 1 to 100. Two dial sizes are available. XVPOC-XVPOCS have 15 turn counting dial. Operators include 3 pc. coupling and device mounting bracket. 9A–14 Catalog No. Description Weight Each Pounds 1/2 XVPO Plain Dial, Panel Mount XVPOS Plain Dial, Surface Mount 1/2 XVPOL Plain Dial, Large Size, Panel Mount 1/2 XVPOSL Plain Dial, Large Size, Surface Mount 1/2 XVPOC Counting Dial, Panel Mount 3/4 XVPOCS Counting Dial, Surface Mount 3/4 POTENTIOMETER NOT FURNISHED — Consult Factory. 284 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 285 Explosionproof and Dust-tight Pilot Lights CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Explosionproof pilot lights are suitable for panel or surface mount applications. All pilot lights are of sealed construction and can be relamped from the front by removal of lens cap. All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible leads, other lengths on special order, or screw terminal (suffix T). All lens caps are black anodized aluminum finish. Maximum installation thickness: 1 15/16” on Long Series, 5/8” on Short Series. This standard series of pilot lights is equipped with candelabra base receptacles and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24, 30, 50, 75 and 135 volt lamps. Specify voltage desired. Catalog No. Panel Mount Catalog No. Surface Mount Description Weight Each Pounds XLA-GH XLSA-GH Amber Lens 1/2 XLB-GH XLSB-GH Blue Lens 1/2 XLC-GH XLSC-GH Clear Lens 1/2 XLG-GH XLSG-GH Green Lens 1/2 XLR-GH XLSR-GH Red Lens 1/2 XLSW-GH White Lens 1/2 XLW-GH *Add suffix T to P/N for screw terminal This special series of pilot lights is equipped with slide base receptacles and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12, 24, 48 and 60 volt lamps. Specify voltage desired. Catalog No. Panel Mount Catalog No. Surface Mount Description Weight Each Pounds XLAS-GH XLSAS-GH Amber Lens 1/2 XLBS-GH XLSBS-GH Blue Lens 1/2 XLCS-GH XLSCS-GH Clear Lens 1/2 XLGS-GH XLSGS-GH Green Lens 1/2 XLRS-GH XLSRS-GH Red Lens 1/2 XLWS-GH XLSWS-GH White Lens 1/2 *Add suffix T to P/N for screw terminal Replacement Guarded Lens Cap Assembly Catalog No. Description Weight Each Pounds XLA-GCH Amber Lens 1/8 XLB-GCH Blue Lens 1/8 XLC-GCH Clear Lens 1/8 XLG-GCH Green Lens 1/8 XLR-GCH Red Lens 1/8 XLW-GCH White Lens 1/8 285 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 9A–15 Guarded Pilot Lights for Group B Application 15599 Sec.9 12/9/01 11:19 AM Page 286 Explosionproof and Dust-tight Pilot Lights CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Guarded Pilot LED Lights for Group B Application LED Advantages: • 10 Year/100,000 hour service life under normal ambient conditions. • 1x to 4x more energy efficient. • Improved resistance to shock and vibration. • LEDs operate significantly cooler than traditional lamps. 9A–16 • Ultra bright cluster LED’s. Explosionproof pilot LED lights are suitable for panel or surface mount applications. All candelabra base LED lights and can be relamped from the front by removal of the lens cap. All pilot LED lights are made with 3/4” NPSM threads. All pilot LED lights have 8” flexible leads, other lengths on special order, or screw terminal. Add suffix T to P/N for screw terminal. All lens caps are black anodized aluminum finish with clear glass lens. Maximum installation thickness: 1-15/16” on Panel Mount (Long Series), 5/8” on Surface Mount (Short Series). Consult Adalet for the availability of other voltages. Catalog No. Panel Mount (Long Series) Catalog No. Surface Mount (Short Series) Description Weight Each Pounds XLRL-GH XLAL-GH XLGL-GH XCWL-GH XLBL-GH XLSRL-GH XLSAL-GH XLSGL-GH XLSWL-GH XLSBL-GH Red Amber Green White Blue 1/2 1/2 1/2 1/2 1/2 *Add suffix T to P/N for screw terminal. 286 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 287 Explosionproof Special Operators and Accessories CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9 Reset Button Operators Description of operations only Weight Each Pounds XRB Reset Button - Short 1/2 XRBL Reset Button - Long 1/2 Used for resetting contactors, relays, etc. in explosionproof and weather-proof enclosures. Made with 3/4” NPSM threaded stem. Standard operating shaft length 6” can be cut to length. Special lengths are also available. Use XRBL for wall thickness greater than 3/4”. 9A–17 XRB / XRBL Catalog No. Close-Up Plugs For Unused Operator Openings Catalog No. Description of operations only Net Weight XPP 3/4” NPSM 3/4 oz. XPP-N4 3/4” NPSM Type 4 3/4 oz. 287 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 288 Explosionproof and Dust-Tight Pilot Lights CLASS I, GROUPS C & D Non-Guarded Lens Caps Cap Color Weight Each lbs. Amber Lens Black 1/2 Blue Lens Black 1/2 XLC-C Clear Lens Black 1/2 • Black Cap XLG-C Green Lens Black 1/2 • Clear Cap XLR-C Red Lens Black 1/2 XLW-C White Lens Black 1/2 XLAC-C Amber Lens Clear 1/2 XLBC-C Blue Lens Clear 1/2 1/2 All lens caps are black anodized aluminum finish. For color coding, Adalet will furnish at no additional charge the following color combinations: • Amber Cap • Green Cap • Blue Cap 9A–18 • Red Cap Catalog No. Description XLA-C XLB-C XLCC-C Clear Lens Clear XLGC-C Green Lens Clear 1/2 XLRC-C Red Lens Clear 1/2 XLWC-C White Lens Clear 1/2 XLAA-C Amber Lens Amber 1/2 XLBA-C Blue Lens Amber 1/2 XLCA-C Clear Lens Amber 1/2 XLGA-C Green Lens Amber 1/2 XLRA-C Red Lens Amber 1/2 XLWA-C White Lens Amber 1/2 XLAG-C Amber Lens Green XLBG-C Blue Lens Green 1/2 XLCG-C Clear Lens Green 1/2 XLGG-C Green Lens Green 1/2 XLRG-C Red Lens Green 1/2 XLWG-C White Lens Green 1/2 XLAB-C Amber Lens Blue 1/2 XLBB-C Blue Lens Blue 1/2 XLCB-C Clear Lens Blue 1/2 XLGB-C Green Lens Blue 1/2 XLRB-C Red Lens Blue 1/2 XLWB-C White Lens Blue 1/2 XLAR-C Amber Lens Red 1/2 XLBR-C Blue Lens Red 1/2 XLCR-C Clear Lens Red 1/2 XLGR-C Green Lens Red 1/2 XLRR-C Red Lens Red 1/2 XLWR-C White Lens Red 1/2 288 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 289 Operator Boots and Hardware Operator Protective Boots Molded silicone rubber, protective boots for use with explosion proof operators in extremely wet-dirty locations. Makes operators suitable for NEMA 3, 4, 4X, 5, 7, 9, 12, 13 application. Boot and metal collar are an integral assembly available as a factory adder or a field replacement. Simple installation requires removal of existing cap and threading on the replacement. XBPC XNP Catalog No. XHDPL XMB Description Weight Each XBB Black Push Button Cap 1 oz. XBG Green Push Button Cap 1 oz. XBR Red Push Button Cap 1 oz. XBSB Black Selector Switch Cap 1 oz. XBSG Green Selector Switch Cap 1 oz. XBSR Red Selector Switch Cap 1 oz. XBPC Clear Pilot Light Push Button Cap 1 oz. 9A–19 XBB XBSB To order as complete operator add part number as suffix. XMC XHPL XMT Catalog No. Description Weight Each XNPWB Black Blank Legend Plate 1/16 XNPWG Green Blank Legend Plate 1/16 XNPWR Red Blank Legend Plate 1/16 Legend plate has foam gasket backing for use with protective boots for sealing. Engraving 1 line only see Price List. XHSPL Push Button and Selector Switch Components Operator locking caps and actuator devices can be adapted to existing explosion proof operators. Simple installation requires removal of top cap and threading on the replacement unit. Legend Plates Standard Marking For Push Button (BLANK) SLOW For Selector switches RESET RUN-JOG OPEN-OFF-CLOSE START OPEN IN HAND-AUTO FAST-OFF-SLOW INCH CLOSE OUT FWD-REV RUN-AUTO-JOG STOP RUN UP JOG FORWARD ON REVERSE FAST OFF BACK LEFT FAST-SLOW HAND-OFF-AUTO RIGHT OPEN-CLOSE FWD-OFF-REV LOW UP-DOWN HIGH OFF-ON DOWN 1-OFF-2 UP-OFF-DOWN Description Weight Each XHDPL Padlock Device for Dual Push Button 1/4 XHPL Padlock Device to activate Push Button 1/4 XHSPL Padlock Device for Selector Switch 1/4 XMB Red Mushroom Head 2 1/4” Button 1/4 XMC Maintained Contact Lever for 1/4 Catalog No. Push Buttons EMERGENCY STOP XMT Catalog No. XNP Description Specify legend Wobble Stick 2 1/2” Long for NC 1/4 Push Button Weight Each XHPLG Padlockable Push Button Cover 1/4 (Not Shown) 1/16 Legend plates are anodized aluminum with engraved letters on black background. Stop has red and start has green background. Special engraved legend plates can be supplied. Mushroom button and wobble stick recommended only for operators with normally closed contact blocks. 289 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 290 Explosionproof Push Button and Selector Switch Components 600 Volts AC Maximum Contact Blocks for Push Buttons and Selector Switches Series BT Catalog Contact Block Push Button BT1A One Open and 1 N.O. One Closed 1 N.C. BT1B Selector Switch Weight Ea. 1/10 One Closed and One Open See Chart 9A–20 (this is BT1A block 1 N.C. rotated 180 degrees 1 N.O. 1/10 1 N.O. 1/10 when assembled to operator) BT2 Two open 1 N.O. 1 N.C. BT3 Two closed 1 N.C. BT4 One open 1 N.O. BT5 One closed 1 N.C. BT44 Two open 1 N.C. Two closed 1 N.O. 1/10 Specify Cam and Contact Block 1/10 1/10 1/10 1 N.O. 1 N.C. Contact Sequence Chart 2-Position Selector Switches Cam 1 Contact Sequence O = Contact Open X = Contact Closed Circuit of Contact Block Contact Block Number 3-Position Selector Switches Cam 2 Cam 3 Cam 4 Contact Contact Contact Sequence Sequence Sequence Cam 5 Cam 6 Contact Contact Sequence Sequence Normally Closed (NC) Normally Open (NO) BT1A Circuit A Circuit B XO OX OX O OO X OXX OOX XOO OXO OXX X XO XOO OXO Normally Closed (NC) Normally Open (NO) BT1B* Circuit B Circuit A XO OX XX O XO X X XO X OO XOX OX X OOX X OO OOX OOX Normally Open(NO) Normally Open (NO) BT2 Circuit A Circuit B OX OX XO X OO X X OO OOX OX X OXO X OO X XO OOX OXO Normally Closed (NC) Normally Closed (NC) BT3 Circuit A Circuit B XO XO OX O XX O OXX X XO XOO XOX OXX OOX XOO OOX * This contact block is same as BT1A one N.C. and one N.O. except rotated 180° when assembled to operator. Maximum Ampere Rating Control Circuit Contacts Type BT AC Volts Make & Emergency Interrupting Capacity Normal Load Break Continuous Current 110 60. 6. 10. 220 30. 3. 10. 440 15. 1.5 10. 550 12. 1.2 10. 120 1.1 1.1 10. DC 240 0.5 0.5 10. 600 0.2 0.2 10. 290 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:19 AM Page 291 Explosionproof and Dust-tight Miniature Operators CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 4, 7 & 9 Features • Reduce size of control enclosure requirements in hazardous environments. • Mount on 1” centers vs. standard operators requiring 2 1/2” centers. • No special enclosures required; can be installed in most Adalet standard explosionproof enclosures. Push Button / Selector Switch Description 9A–21 • 3/8”-16 UNC thread size body. • Black anodized body, cap, button or knob • Two lengths available: Long Series Accommodates up to 1 9/16” enclosure wall thickness Short Series Accommodates up to 13/16” enclosure wall thickness • Stainless steel actuator shaft. • Optional red or green button (Push button Operator only) Push Buttons XMOB Catalog No. Panel Mount Catalog No. Surface Mount Contact Configurations Weight Each XMOB-1 XMOB-2 XMOBS-1 SPDT maintained 1 oz. XMOBS-2 SPDT momentary 1 oz. XMOB-3* XMOBS-3* DPDT maintained 1 oz. XMOB-4 XMOBS-4 DPDT momentary 1 oz. * Not UL or CSA Approved • Solid silver contacts rated 5 amps at 125 VAC, 3 amps at 250 VAC. • Insulation resistance 1000 megohm minimum. • Furnished with contact block having 8” wire leads, other lengths available. Selector Switches XMOS Catalog No. Panel Mount Catalog No. Surface Mount Contact Configurations Weight Each XMOS-1 XMOSS-1 Single Pole, 12 position 1 oz. XMOS-2 XMOSS-2 Double Pole, 5 position 1 oz. XMOS-3 XMOSS-3 Three Pole, 3 position 1 oz. • Selector switches provided with internal adjustable stop. • Silver contacts rated 150 m.a. at 30 VAC, NEC CL 2 circuit. • Insulation resistance 10,000 megohms minimum. • Furnished with contact block having solder type wire connectors. 291 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.9 12/9/01 11:20 AM Page 292 Explosionproof and Dust-tight Miniature Operators CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 4, 7, 9 For Explosionproof Control Enclosures Indicator Led Light Description 9A–22 • Up to 100,000 hours lamp life. • Standard 12 VDC furnished. Optional 24 VDC, or 12, 24, 120 VAC available. • Black anodized body and lens cap. • 3/8” - 16 UNC thread size body. • One length-accommodates up to 1 5/16” enclosure wall thickness. • Furnished with 8” flexible wire leads, other lengths available. Catalog No. Description Weight Each 1 oz. XMOLR Red Indicator Light XMOLA Amber Indicator Light 1 oz. XMOLG Green Indicator Light 1 oz. Close-Up Plugs for Unused Operator Openings Catalog No. Weight XMPP 1/2 oz. Legend Plates Standard Marking Catalog No. Description Weight Each XMNP Specify legend 1/2 oz. For Push Button Compliances: NEC Class I, Groups B, C & D Class II, Groups E, F & G UL Standard 698 CSA Standard C22.2 No. 30 For Selector switches (BLANK) SLOW RESET RUN-JOG START OPEN IN HAND-AUTO INCH CLOSE OUT FWD-REV STOP UP LEFT FAST-SLOW RUN JOG RIGHT OPEN-CLOSE FORWARD ON LOW UP-DOWN REVERSE OFF HIGH OFF-ON FAST BACK • Legend plates are anodized aluminum with engraved letters on black background. • Maximum 10 characters, 5/64” high offered as standard. NOTE: Special engraved legend plates can be supplied. 292 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:21 AM Page 293 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 MULTI-HUB BOXES Designed for general wiring in hazardous locations. For pulling and splicing conductors. Serves as mounting outlets with use of appropriate fixture covers. Available with dome cover for additional splicing room and mounting of various devices. Bodies XJAB, XJAD and XJAX 26 thru 46 have two interior mounting bosses, which can be blind tapped. Bodies XJAC, XJAL and XJAT 26 thru 46 have four interior mounting bosses, which can be blind tapped. All bodies 570 thru 890 have solid back, can be tapped blind. Conduit Size (In.) Standard Pkg. Quantity Standard Pkg. Weight Lbs. XJAB-26 1/2 10 9 XJAB-36 3/4 10 10 XJAB-46 1 10 12 XJAB-570 1 1/4 5 25 XJAB-690 1 1/2 4 22 XJAB-890 2 4 23 XJAC-26 1/2 10 9 XJAC-36 3/4 10 10 XJAC-46 1 10 12 XJAC-570 1 1/4 5 26 XJAC-690 1 1/2 4 21 XJAC-890 2 4 23 XJAD-36 3/4 10 9 XJAD-46 1 10 15 XJAL-26 1/2 10 9 XJAL-36 3/4 10 10 XJAL-46 1 10 12 XJAL-570 1 1/4 5 26 XJAL-690 1 1/2 4 21 XJAL-890 2 4 23 10A–1 Catalog Number Compliances • NEC Class I, Groups C, D Class II, Groups E, F, G NEMA 4 WATERTIGHT OPTIONAL: Consult factory for availability and/or certifications. • UL Standard 886 - CSA Standard C22.2 No. 30 293 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:21 AM Page 294 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 MULTI-HUB BOXES XJAL (No bottom hub) Catalog Number Conduit Size (In.) Standard Pkg. Quantity Standard Pkg. Weight Lbs. XJAT-26 1/2 10 10 XJAT-36 3/4 10 10 XJAT-46 1 10 13 XJAT-570 1 1/4 5 27 XJAT-690 1 1/2 4 21 XJAT-890 2 4 23 XJAX-26 1/2 10 12 XJAX-36 3/4 10 14 XJAX-46 1 10 15 XJAX-570 1 1/4 5 27 XJAX-690 1 1/2 4 21 XJAX890 2 4 23 10A–2 XJAT (No bottom hub) XJAX (No bottom hub) Compliances • NEC Class I, Groups C, D Class II, Groups E, F, G NEMA 4 WATERTIGHT OPTIONAL: Consult factory for availability and/or certifications. • UL Standard 886 - CSA Standard C22.2 No. 30 294 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:21 AM Page 295 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES CLASS I, GROUPS C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 MULTI-HUB BOXES BLANK COVERS Catalog Number Description St. Pkg. Std. Pkg. Weight Lbs. XJA6 For 1/2" – 3/4" – 1" Bodies 10 5 XJA8 For 1 1/4" – 1 1/2" – 2" Bodies 5 11 SEALING COVERS XJA6 Catalog Number Description St. Pkg. Std. Pkg. Weight Lbs. XJA6S For 1/2" – 3/4" – 1" Bodies 10 7 10A–3 Entire body must be filled with sealing compound. NEC prohibits splices and taps in sealing fittings. DOME COVERS Catalog Number XJA6S Description St. Pkg. Std. Pkg. Weight Lbs. XJADC For 1/2" – 3/4" – 1" Bodies Inside Depth 2 3/8" 10 9 XJAD4 For 1 1/4" – 1 1/2" – 2" Bodies Inside Depth 4 1/8" 1 5 XJAD6 For 1 1/4" – 1 1/2" – 2" Bodies Inside Depth 6" 1 6 XJAD10 For 1 1/4" – 1 1/2" – 2" Bodies Inside Depth 10" 1 8 1/2 XJAD13 For 1 1/4" – 1 1/2" – 2" Bodies Inside Depth 13" 1 9 1/2 XJAO O-Ring For NEMA 4 watertight For 1/2" – 3/8" – 1" Bodies 1 — XJTO O-Ring for NEMA 4 watertight For 1 1/4" – 1 1/2" – 2" Bodies 1 — XJADC 295 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:21 AM Page 296 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS CLASS I, GROUPS B*, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Sealing Fittings are required in Hazardous Locations and are used to isolate arc-producing devices in conduit and wiring systems, and to prevent the passage of explosive pressures from one area to another. FOR HORIZONTAL AND VERTICAL MOUNTING - Type XYB and XYBM are suitable for either horizontal or vertical mounting and are provided with threaded plugged openings into which fiber and cement can be placed to form effective seal. XYB has female ends for conduit entrance. The XYBM has female ends with a removable threaded nipple. *1/2”, 3/4”, 1” sizes Class I, Group B, C, D, Class II, E, F, G. XYB-XYBM 1 1/4”, 1 1/2”, 2”, 2 1/2”, 3”, 3 1/2”, 4” sizes Class I, Group C, D Class II, E, F, G CSA Certified LR27991 UL Listed E10493 10A–4 Catalog No. Description Conduit Size (In.) Ounces Req. For Each Sealing Fitting Cement Fiber Standard Package Qty. Tot. Wt. Lbs. Female-Female Catalog No. Description Conduit Size (In.) Ounces Req. For Each Sealing Fitting Cement Fiber Standard Package Qty. Tot. Wt. Lbs. Male-Female XYB-2 1/2 1 1/8 5 2.1 XYBM-2 1/2 1 1/8 5 2.2 XYB-3 3/4 2 1/4 5 2.6 XYBM-3 3/4 2 1/4 5 2.7 XYB-4 1 3 1/4 5 3.7 XYBM-4 1 3 1/4 5 3.8 XYB-5 1-1/4 6 3/8 2 2.5 XYBM-5 1-1/4 6 3/8 2 2.6 XYB-6 1-1/2 9 1/2 2 3.2 XYBM-6 1-1/2 9 1/2 2 3.4 XYB-8 2 18 3/4 2 5.6 XYBM-8 2 18 3/4 2 5.9 XYB-10 2-1/2 23 1-1/2 2 6.2 XYBM-10 2-1/2 23 1-1/2 2 6.8 XYB-12 3 48 3-1/8 1 6.0 XYBM-12 3 48 3-1/8 1 6.3 XYB-14 3-1/2 70 4-1/2 1 6.8 XYBM-14 3-1/2 70 4-1/2 1 7.3 XYB-16 4 90 6 1 8.3 XYBM-16 4 90 6 1 8.8 Nominal Dimensions (Inches) Conduit Size (XYBM Series Only) D C Turn Radius R A B 1/2 3-19/32 1-13/16 5/8 11/16 1-3/16 3/4 3-25/32 2-1/16 3/4 15/16 1-5/16 1 4-3/8 2-5/16 7/8 15/16 1-7/16 1-1/4 5-5/32 2-13/16 1-1/16 1-1/16 1-3/4 1-1/2 5-11/16 3-3/16 1-3/16 1-3/16 2 2 6-13/16 3-7/8 1-1/2 1-7/16 2-3/8 2-1/2 7-1/2 4-1/2 1-7/8 1-5/8 2-11/16 3 9-9/16 5-1/2 2-3/16 1-7/8 3-5/16 3-1/2 9-1/2 6-1/6 2-3/8 2 3-11/16 4 9-9/16 6-1/2 2-5/8 2-1/8 3-7/8 Compliances • NEC Class I, Groups B, C, D Class II, Groups E, F, G • UL Standard 886 - CSA Standard C22.2 No. 30 296 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:21 AM Page 297 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS CLASS I, GROUPS B*, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Sealing Fittings are used for the same application as the standard Adalet sealing fitting but allow up to 40% wire fill in the fitting. *1/2”, 3/4” sizes Class I, Group B, C, D, Class II, E, F, G. 1”, 1-1/4”, 1-1/2”, 2”, 2-1/2”, 3” sizes Class I, Group C, D, Class II, E, F, G. XYB-XYBM CSA Certified LR27991 Catalog No. Description Conduit Size (In.) Ounces Req. For Each Sealing Fitting Cement Fiber Standard Package Qty. Tot. Wt. Lbs. Catalog No. Description Conduit Size (In.) Ounces Req. For Each Sealing Fitting Cement Fiber Standard Package Qty. Tot. Wt. Lbs. Male-Female Female-Female XYB-34 1/2 2 1/4 5 2.6 XYBM-34 1/2 2 1/4 5 2.7 XYB-44 3/4 3 1/4 5 3.7 XYBM-44 3/4 3 1/4 5 3.8 XYB-54 1 6 3/8 2 2.5 XYBM-54 1 6 3/8 2 2.6 XYB-84 1-1/4 18 3/4 2 5.6 XYBM-84 1-1/4 18 3/4 2 5.9 XYB-104 1-1/2 23 1-1/2 2 6.2 XYBM-104 1-1/2 23 1-1/2 2 6.8 XYB-124 2 48 3-1/8 1 6.0 XYBM-124 2 48 3-1/8 1 6.3 XYB-144 2-1/2 70 4-1/2 1 6.8 XYBM-144 2-1/2 70 4-1/2 1 7.3 XYB-164 3 90 6 1 8.3 XYBM-164 3 90 6 1 8.8 Nominal Dimensions (Inches) Conduit Size A B C (XYBM Series Only) D Turn Radius R 1/2 3-25/32 2-1/16 3/4 15/16 1-5/16 3/4 4-3/8 2-5/16 7/8 15/16 1-7/16 1 5-5/32 2-13/16 1-1/16 1-1/16 1-3/4 1-1/4 6-13/16 3-7/8 1-1/2 1-7/16 2-3/8 1-1/2 7-1/2 4-1/2 1-7/8 1-5/8 2-11/16 2 9-9/16 5-1/2 2-3/16 1-7/8 3-5/16 2-1/2 9-1/2 6-1/16 2-3/8 2 3-11/16 3 9-9/16 6-1/2 2-5/8 2-1/8 3-7/8 Compliances • NEC Class I, Groups B, C, D Class II, Groups E, F, G • UL Standard 886 - CSA Standard C22.2 No. 30 297 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 10A–5 UL Listed E10493 15599 Sec.10 12/9/01 11:21 AM Page 298 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Adalet Sealing Fittings are used to isolate arc-producing devices from wiring systems and to prevent the spread of explosive gases. XY 2-3-4 XYM 2-3-4 FOR VERTICAL MOUNTING Types XY and XYM Fittings are for vertical mounting, and are provided with threaded plugged openings into which the sealing cement is poured. Sizes 1-1/4” x 1-1/2” have large plugged openings in the lower hub to facilitate packing fiber around the wires to form a dam. Type XYM’s have removable threaded nipples. The two hubs are tapped simultaneously to assure alignment of the conduits, especially important to equipment manufacturers using short runs of conduit. FOR HORIZONTAL & VERTICAL MOUNTING Type XYC Fittings are for horizontal mounting only, with the cover opening in an upright position. XYCS fittings are for vertical or horizontal mounting, with removable threaded covers which can be turned to the desired position for pouring in the sealing cement. The covers are interchangeable. The male-to-female types have removable threaded nipple. 10A–6 Catalog Number XY 5-6 XYC XYM 5-6 XYCM Ounces Required per Fitting Standard Package Female/ Female Male/ Female Conduit Size (In.) XY2 XYM2 1/2 1 1/8 25 XY3 XYM3 3/4 1 1/4 25 10 XY4 XYM4 1 2 1/4 25 12-1/2 XY5 XYM5 1-1/4 4 3/8 10 7-1/2 XY6 XYM6 1-1/2 5 1/2 10 10 XYC2 XYC2M 1/2 2 1/8 25 13 XYC3 XYC3M 3/4 2 1/4 25 13 XYC4 XYCM4 1 4-1/2 1/4 25 15 XYC5 XYC5M 1-1/4 8-1/2 3/8 10 10 XYC6 XYC6M 1-1/2 11-1/2 1/2 10 11 12 Sealing Cement Packing Fiber Qty Weight Lbs. 10 XYC8 XYC8M 2 13-1/2 3/4 10 XYC10 XYC10M 2-1/2 15 1-1/2 1 2 XYC12 XYC12M 3 31-1/2 3-1/8 1 3 XYC14 XYC14M 3-1/2 42-1/2 4-1/2 1 4 XYC16 XYC16M 4 51 6 1 5 XYC2S XYC2SM 1/2 2 1/8 25 13 XYC3S XYC3SM 3/4 2 1/4 25 13 XYC4S XYC4SM 1 3 1/4 25 15 XYC5S XYC5SM 1-1/4 6-1/2 3/8 10 10 XYC6S XYC6SM 1-1/2 10 1/2 10 11 XYC8S XYC8SM 2 12-1/2 3/4 10 12 XYC10S XYC10SM 2-1/2 13-1/2 1-1/2 1 2 XYC12S XYC12SM 3 29-1/2 3-1/8 1 3 Compliances XYC14S XYC14SM 3-1/2 40 4-1/2 1 4 • NEC Class I, Group D Class II, Groups E, F, G • UL Standard 886 - CSA Standard C22.2 No. 30 XYC16S XYC16SM 4 48-1/2 6 1 5 XYCS XYCSM CSA Certified LR27991 UL Listed E10493 298 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 299 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Adalet 40% Fill Sealing Fittings are used for the same applications as the standard Adalet Sealing Fittings, but allow up to 40% wire fill in the fitting. XY 54 XYC 34XYC 164 XYC 34SXYC 164S XYM 34, 44 Catalog Number XYM 54 XYC 34MXYC 164M Ounces Required per Fitting Standard Package Female/ Female Male/ Female Conduit Size (In.) XY34 XYM34 1/2 1 1/4 25 10 XY44 XYM44 3/4 2 1/4 25 12-1/2 7-1/2 Sealing Cement Packing Fiber Qty Weight Lbs. XY54 XYM54 1 4 3/8 10 XYC34 XYC34M 1/2 2 1/4 25 13 XYC44 XYC44M 3/4 4-1/2 1/4 25 15 XYC54 XYC54M 1 8-1/2 3/8 10 10 XYC84 XYC84M 1-1/4 13-1/2 3/4 10 12 XYC104 XYC104M 1-1/2 15 1-1/2 1 2 XYC124 XYC124M 2 31-1/2 3-1/8 1 3 XYC144 XYC144M 2-1/2 42-1/2 4-1/2 1 4 XYC164 XYC164M 3 51 6 1 5 XYC34S XYC34SM 1/2 2 1/4 25 13 XYC44S XYC44SM 3/4 3 1/4 25 15 XYC54S XYC54SM 1 6-1/2 3/8 10 10 XYC84S XYC84SM 1-1/4 12-1/2 3/4 10 12 XYC104S XYC104SM 1-1/2 13-1/2 1-1/2 1 2 XYC124S XYC124SM 2 29-1/2 3-1/8 1 3 XYC144S XYC144SM 2-1/2 40 4-1/2 1 4 XYC164S XYC164SM 3 48-1/2 6 1 5 XYC 34SMXYC 164SM Compliances • NEC Class I, Group D Class II, Groups E, F, G CSA Certified LR27991 • UL Standard 886 - CSA Standard C22.2 No. 30 UL Listed E10493 299 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 10A–7 XY 34, 44 15599 Sec.10 12/9/01 11:22 AM Page 300 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Dimensions (In.) Catalog Number 10A–8 CSA Certified LR27991 UL Listed E10493 R = Turning Nominal Dimensions, (In.) Radius (Inches) Female/ Female Male/ Female Conduit Size A B C D XY2 XYM2 1/2 3-1/16 2-7/16 3/4 11/16 1-13/16 XY3 XYM3 3/4 3-1/16 2-7/16 3/4 1 1-13/16 XY4 XYM4 1 3-3/4 2-15/16 15/16 15/16 2-1/8 XY5 XYM5 1-1/4 4-15/16 3-3/16 1-3/16 1-1/8 2-1/8 E Plain Cover Sealing Cover XY6 XYM6 1-1/2 4-7/8 3-7/16 1-5/16 1-5/16 XYC2 XYC2M 1/2 3-1/16 2-9/16 2-1/6 5/8 13/16 1-7/8 2-11/16 XYC2S XYC2SM 3/4 3-1/6 2-9/16 2-1/16 15/16 13/16 1-7/8 2-11/16 1 3-11/16 2-11/16 2-3/8 15/16 1 2-1/8 3-1/16 1-1/4 4-1/2 3-3/16 3-3/8 1-1/16 7/8 2-11/16 3-1/16 1-1/2 4-1/2 3-7/16 3-3/8 1-1/8 7/8 2-11/16 3-1/16 2 4-11/16 4 3-3/8 1-3/8 7/8 3 3-5/16 2-1/2 5-5/16 4-5/8 3-3/8 1-5/8 7/8 3-1/4 3-3/4 3 6-7/16 5-7/16 3-15/16 1-3/4 1-3/8 4 4-5/8 3-1/2 6-9/16 6-3/8 4-3/4 1-5/8 1-5/16 4-5/8 5 4 6-15/16 6-13/16 4-3/4 2 1-5/16 4-3/4 5-3/8 XYC3 XYC3M XYC3S XYC3SM XYC4 XYC4M XYC4 XYC4SM XYC5 XYC5M XYC5S XYC5SM XYC6 XYC6M XYC6S XYC6SM XYC8 XYC8M XYC8S XYC8SM XYC10 XYC10M XYC10S XYC10SM XYC12 XYC12M XYC12S XYC12SM XYC14 XYC14M XYC14S XYC14SM XYC16 XYC16M No Cover 2-1/4 ADACO SEALING CEMENT AND ADACO PACKING FIBER CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 XSC XAF Catalog No. Description XSC-8 ADACO No. 1 Net Weight 8 oz. XSC-16 Sealing 16 oz. XSC-160 Cement 10 lbs. 1-1/2 oz. XAF-6 ADACO XAF-24 Packing 6 oz. XAF-64 Fiber 1 lb. ADACO SEALING CEMENT is the easiest-to-use sealing cement on the market. The powder is contained in a polyethylene bag within an outer container. To mix, remove the bag of powder, fill the outside container with water up to the marked “water line” and pour in the powder. Simple...no guesswork about how much water to use. The mixing container is right there...and clean. The largest unit package offered contains one pound of powder. The XSC-160 (10-pound quantity) consists of 10, one-pound packages (at the ten-pound price) so that every mix is correct. This cement has been especially prepared for use in Adalet Sealing Fittings. It is not an insulating compound, and is not affected by gasoline, alcohol, benzol, oils, acetone or lacquer solvents. ADACO PACKING FIBER is used with Adaco Sealing Cement for plugging conduit openings in fittings. Alumina Silica based long fiber non-asbestos for use as a packing at the hubs of sealing units to prevent the Sealing Cement in the liquid state from entering the conduit lines. The Fiber is tamped between the wires and the hub before the Sealing Cement is poured into the fitting. 300 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 301 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 R = Turning Nominal Dimensions, (In.) Radius (Inches) Female/ Female Male/ Female Conduit Size A XY34 XYM34 1/2 3-1/6 2-7/16 3/4 1 XY44 XYM44 3/4 3-3/4 2-15/16 15/16 15/16 3-1/8 XY54 XYM54 1 4-15/16 3-3/16 1-3/16 1-1/8 2-1/8 XYC34 XYC34M 1/2 3-1/6 2-9/16 2-1/16 15/16 13/16 1-7/8 2-11/16 XYC34S XYC34SM 3/4 3-11/16 2-11/16 2-3/8 15/16 1 2-1/8 3-1/16 1 4-1/2 3-3/16 3-3/8 1-1/16 7/8 2-11/16 3-1/16 1-1/4 4-11/16 4 3-3/8 1-3/8 7/8 3 3-5/16 1-1/2 5-5/16 4-5/8 3-3/8 1-5/8 7/8 3-1/4 3-3/4 2 6-7/16 5-7/16 3-15/16 1-3/4 1-3/8 4 4-5/8 2-1/2 6-9/16 6-3/8 4-3/4 1-5/8 1-5/16 4-5/8 5 3 6-15/16 6-13/16 4-3/4 2 1-5/16 4-3/4 5-3/8 XYC44 XYC44M XYC4S XYC44SM XYC54 XYC54M XYC54S XYC54SM XYC84 XYC84M XYC84S XYC84SM XYC104 XYC104M XYC104S XYC104SM XYC124 XYC124M XYC124S XYC124SM XYC144 XYC144M XYC144S XYC144SM XYC164 XYC164M XYC164S XYC164SM B C D 10A–9 Dimensions (In.) Catalog Number E Plain Cover Sealing Cover No Cover 1-13/16 301 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 302 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT SHORT RADIUS PULL ELBOWS CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & 9 This versatile and inexpensive explosion-proof fitting with a threaded cover will easily and compactly handle 90° conduit runs. FL series have two female entrances. MFL series has one female entrance and one removable threaded nipple. Nominal Dimensions Inches FL MFL 10A–10 Compliances • NEC Class I, Group D Class II, Groups E, F, G Standard Package Catalog Number Conduit Size (In.) FL92 1/2 2-5/8 2-1/8 1-3/8 25 8 FL93 3/4 2-13/16 2-1/8 1-1/2 25 10-1/2 A B C Quantity Weight Pounds FL94 1 3-1/4 2-7/16 1-7/8 25 11 FL95 1-1/4 3-3/4 3-1/2 2-1/4 25 24 30 *FL96 1-1/2 4-5/8 4-3/16 2-5/8 25 MFL92 1/2 2-5/8 2-1/8 1-3/8 25 9 MFL93 3/4 2-13/16 2-1/8 1-1/2 25 12 MFL94 1 3-1/4 2-7/16 1-7/8 25 13 MFL95 1-1/4 3-3/4 3-1/2 2-1/4 25 26 *MFL96 1-1/2 4-5/8 4-3/16 2-5/8 25 34 * Fitting not UL Listed or CSA Certified • UL Standard 886 - CSA Standard C22.2 No. 30 CSA Certified LR27991 UL Listed E10493 EXPLOSIONPROOF AND DUST-TIGHT REMOVABLE PLUGS CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Tapered thread close-up plugs for explosionproof conduit entrances. Provides 5 full threads of engagement. Made of aluminum alloy, these plugs have screw-driver slots and fit practically flush when installed. Standard Package OX Weight Pounds Standard Package Catalog Number Conduit Size (In.) Catalog Number Conduit Size (In.) Qty OX2 1/2 250 6-3/4 OX8 2 50 12 OX3 3/4 250 10-1/4 OX10 2-1/2 50 20-1/2 Qty Weight Pounds OX4 1 150 9 OX12 3 50 30 OX5 1-1/4 100 12 OX14 3-1/2 50 40 OX6 1-1/2 100 14-1/2 OX16 4 50 52 302 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 303 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT CONDUIT UNIONS CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Explosionproof unions for use in conduit piping systems for ease of installation and removal of fittings, boxes and equipment enclosures in hazardous atmosphere areas. Parts are steel, cadmium plated for corrosion protection. Style XU has two female NPT threads. Style XUM has two female NPT threads and one plated threaded nipple. Standard Package Conduit Size Qty Weight Pounds XU2 1/2” XU3 3/4” Female-Female 50 19 Female-Female 50 XU4 1” 21 Female-Female 25 13-1/2 XUM2 XUM3 1/2” Female-Male 50 22 3/4” Female-Male 50 XUM4 26 1” Female-Male 25 16-1/2 10A–11 XU Catalog Number DIMENSIONS Conduit Size A B Series 1/2” 1-3/4” 1-1/2” XU 3/4” 1-3/4” 1-3/4” 1” 1-15/16” 2” Series 1/2” 2-9/16” 1-1/2” XUM 3/4” 2-3/4” 1-3/4” 1” 3” 2” XUM Compliance • NEC Class I, Groups A, B, C, D Class II, Groups E, F, G • UL Standard 886 - CSA Standard C22.2 No.30 CSA Certified LR27991 UL Listed E10493 303 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 304 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT FLEXIBLE COUPLINGS *CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Application: XFC couplings are for use in Hazardous Atmospheres where a flexible connection is required for motor and equipment installation where movement and vibration are present. Also for difficult bends and connections. Material: Brass and bronze end fittings. Bronze wire flexible braid covering over flexible bronze core with insulating liner. INCLUDES TWO REMOVABLE ZINC CLEAR COATED NIPPLES. NOTE: For stainless steel in 1/2" and 3/4" sizes add SS suffix (XFCSS-) nipples not included. Nominal Dimensions (inches) 10A–12 Catalog Number Conduit Size Flex Length Weight Pounds Catalog Number Conduit Size Flex Length Weight Pounds XFC-24 1/2 4 1-3/4 XFC-410 1 10 2-5/8 XFC-26 1/2 6 2 XFC-412 1 12 2-3/4 XFC-28 1/2 8 2-1/2 XFC-415 1 15 3 XFC-210 1/2 10 2-3/8 XFC-418 1 18 3-1/4 XFC-212 1/2 12 2-1/2 XFC-421 1 21 3-1/2 XFC-215 1/2 15 2-5/8 XFC-424 1 24 3-3/4 XFC-218 1/2 18 3 XFC-427 1 27 4-1/8 XFC-221 1/2 21 3-1/8 XFC-430 1 30 4-1/2 XFC-224 1/2 24 3-1/4 XFC-433 1 33 4-7/8 XFC-227 1/2 27 3-3/8 XFC-436 1 36 5-1/4 XFC-230 1/2 30 3-1/2 XFC-512 1-1/4 12 6-1/2 XFC-233 1/2 33 3-3/4 XFC-515 1/14 15 7 XFC-236 1/2 36 4 XFC-518 1-1/4 18 7-1/2 XFC-34 3/4 4 2 XFC-521 1-1/4 21 8-1/4 XFC-36 3/4 6 2-1/4 XFC-524 1-1/4 24 8-3/4 XFC-38 3/4 8 2-3/8 XFC-527 1-1/4 27 9-1/2 XFC-310 3/4 10 2-1/2 XFC-530 1-1/4 30 10-1/4 XFC-312 3/4 12 2-5/8 XFC-533 1-1/4 33 10-3/4 XFC-315 3/4 15 3 XFC-536 1-1/4 36 11-1/4 XFC-318 3/4 18 3-1/8 XFC-612 1-1/2 12 8-1/4 XFC-321 3/4 21 3-1/4 XFC-615 1-1/2 15 9 XFC-324 3/4 24 3-3/8 XFC-618 1-1/2 18 10 XFC-327 3/4 27 3-1/2 XFC-621 1-1/2 21 11 XFC-330 3/4 30 3-3/4 XFC-624 1-1/2 24 12 XFC-333 3/4 33 4 XFC-627 1-1/2 27 13 XFC-336 3/4 36 4-1/2 XFC-630 1-1/2 30 14 XFC-46 1 6 2-1/4 XFC-633 1-1/2 33 15 XFC-48 1 8 2-1/2 XFC-636 1-1/2 36 16 CSA Certified LR27991 Nominal Dimensions (inches) Catalog Number Series Conduit Size Min. Radius Bend Classification* A B C 1/2 Class I & II 1-11/16 2-5/16 1-7/16 12 3/4 Group A, B, C, D, E, F & G 1-3/4 2-5/8 1-7/8 14 14 1 XFC Class I & II Group C, D, E, F & G 2 3 2-5/16 1-1/4 Class I & II 2-1/8 3-3/8 2-3/4 16 1-1/2 Group D, E, F & G 2-1/2 3-7/8 3-5/16 16 UL Listed E10493 Compliances • NEC Class I, Groups A, B, C, D Class II, Groups E, F, G • UL Standard 886 - CSA Standard C22.2 No. 30 304 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 305 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT FLEXIBLE COUPLINGS *CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Application: XFCU couplings are for use in Hazardous Atmospheres where a flexible connection is required for motor and equipment installation where movement and vibration are present. Also for difficult bends and connections. Material: Brass and bronze end fittings. Bronze wire flexible braid covering over flexible bronze core with insulating liner. INCLUDES ONE REMOVABLE ZINC CLEAR COATED NIPPLE ON ONE SIDE AND ONE UNION FITTING ON THE OTHER SIDE. Nominal Dimensions (inches) CSA Certified LR27991 Conduit Size Flex Length XFCU-24 1/2 4 XFCU-26 1/2 6 Weight Pounds Catalog Number Conduit Size Flex Length Weight Pounds 2 XFCU-410 1 10 3 2-1/4 XFCU-412 1 12 3-1/8 XFCU-28 1/2 8 2-1/2 XFCU-415 1 15 3-3/8 XFCU-210 1/2 10 2-5/8 XFCU-418 1 18 3-5/8 XFCU-212 1/2 12 2-3/4 XFCU-421 1 21 3-7/8 XFCU-215 1/2 15 3-1/8 XFCU-424 1 24 4-1/8 XFCU-218 1/2 18 3-1/4 XFCU-427 1 27 4-1/2 XFCU-221 1/2 21 3-3/8 XFCU-430 1 30 4-5/8 XFCU-224 1/2 24 3-1/2 XFCU-433 1 33 5-1/8 XFCU-227 1/2 27 3-5/8 XFCU-436 1 36 5-1/2 XFCU-230 1/2 30 3-3/4 XFCU-233 1/2 33 4 XFCU-236 1/2 36 4-1/4 XFCU-34 3/4 4 2-1/4 XFCU-36 3/4 6 2-1/2 XFCU-38 3/4 8 2-5/8 XFCU-310 3/4 10 2-3/4 XFCU-312 3/4 12 3-1/8 XFCU-315 3/4 15 3-1/4 XFCU-318 3/4 18 3-3/8 XFCU-321 3/4 21 3-1/2 XFCU-324 3/4 24 3-5/8 XFCU-327 3/4 27 3-3/4 XFCU-330 3/4 30 4 XFCU-333 3/4 33 4-1/4 XFCU-336 3/4 36 4-3/4 XFCU-46 1 6 2-5/8 XFCU-48 1 8 2-7/8 10A–13 Catalog Number UL Listed E10493 Nominal Dimensions (inches) Catalog Number Series Conduit Size Classification* A B C D E 1/2 Class I & II 1-11/16 2-5/16 1-7/16 2-7/16 1-1/2 12 3/4 Group A,B,C,D,E,F & G 1-3/4 2-5/8 1-7/8 2-1/2 1-3/4 14 1 Group C,D,E,F & G 2 3 2-5/16 2-13/16 2 14 XFCU Min. Radius Bend Class I & II Compliances • NEC Class I, Groups A, B, C, D Class II, Groups E, F, G • UL Standard 886 - CSA Standard C22.2 No. 30 305 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 306 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF AND DUST-TIGHT COMBINATION BREATHER/DRAIN CLASS I, GROUPS C & D; CLASS II, GROUPS F & G; NEMA 7 & NEMA 9 Stainless steel combination breather drain. Install in top of enclosures as breather. Install in bottom of enclosure as drain. A Nominal Dimensions (inches) Catalog Number Thread A B XDB2 1/2 NPT 1-5/8 7/8 hex B Compliances • NEC Class I, Groups C, D Class II, Groups E, F, G - Class III XDB2 • UL Standard 886 - CSA Standard C22.2 No. 30 10A–14 CSA Certified LR27991 UL Listed E10493 EXPLOSIONPROOF AND DUST-TIGHT COMBINATION BREATHER/DRAIN CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9 Nominal Dimensions (inches) C A XDBH2 Catalog Number Thread A B C XDBH2 1/2 NPT 2-7/16 7/8 HEX 1-1/4 Flow Rate: .01 CFM air .5 cc/minute water Certifications • Class I, Groups A, B, C and D Class II, Groups E, F & G - Class III UL and CSA UL Standard 886 - CSA Standard C22.2 No. 30 CSA Certified LR27991 • CENELEC EExd IIB DEMKO 00E.004127U UL Listed E10493 306 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 307 Explosionproof and Dust-tight Fittings and Accessories EXPLOSIONPROOF FLAME ARRESTOR FITTING CLASS I, GROUPS B*, C & D NEMA 7 APPLICATION: Provides thru-wall connections of tubing systems for electro/pneumatic and gas analysis devices installed within Adalet’s explosion proof enclosures. The flame arrestor fitting is designed to prevent flame propagation thru tubing systems with minimum flow restrictions of control pressures. Typical XFA2 MATERIAL: Stainless steel Catalog Number Description Weight XFA2 1/2” NPT 4 oz. XFAX2 1/2” NPT 4 oz. 10A–15 Typical XFAX2 Exterior enclosure wall counter boring may be required to maintain 1/2” enclosure wall thickness for ease of field connections. XFA2 Approximate Control Restrictions *XFAX2 Approximate Control Restrictions * 0.5 PSI drop at 20 CFH airflow * 1.3 PSI drop at 34 CFH airflow 1 PSI drop at 18 CFH airflow 5 PSI drop at 53 CFH airflow * * * * UL and CSA Class I, Groups B, C & D CENELEC EExd Group IIB DEMKO 00E.0041270 NEC Class I, Groups C & D UL Recognized Component CSA Certified Component CENELEC EExd Group IIB CSA Certified LR27991 UL Recognized E10493 307 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 308 Fittings and Accessories SALI INSULATING BUSHINGS (SUPERIOR ADALET LAMINATED INSULATION) Specifications: • 11,000 psi tensile • 17,000 flexural • 450v/mil dielectric • Heat resistance - 150° C, continuous • Moisture absorption - 1/2 of 1% • Listed by Underwriters Laboratories for your quality assurance. • Sali bushings have been repeatedly proved in a wide variety of applications over a 25 year period. Sali bushings are machined from paper laminated phenolic material and comply with NEMA-X phenolic material specifications. TYPE PE-FEMALE-DEEP-THREADED Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) PE-2 1/2 50 1-1/2 5/8 1-1/8 5/8 PE-3 3/4 50 2 13/16 1-5/16 5/8 I.D. Nominal Dimensions (Inches) O.D. Height 10A–16 E10016 LISTED Recommended for rigid conduit or in combination with male type PEM when maximum thread engagement is required. PE-4 1 50 3-1/2 1 1-5/8 25/32 PE-5 1-1/4 25 4-1/2 1-3/8 2 25/32 PE-6 1-1/2 25 5-1/2 1-5/8 2-1/4 25/32 PE-8 2 10 7-1/2 2 2-3/4 25/32 PE-10 2-1/2 5 12 2-7/16 3-1/4 1 PE-12 3 5 16 3 3-7/8 1-1/16 PE-14 3-1/2 5 19 3-1/2 4-3/8 1-1/16 PE-16 4 2 24 4 5 1-1/16 TYPE PES-FEMALE-SHALLOW-THREADED E10016 LISTED Designed for general use on rigid conduit, connectors, and similar installations where the additional mechanical strength of the deep type bushings is not needed. Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) PES-2 1/2 50 1-1/2 5/8 1-1/8 1/2 PES-3 3/4 50 2 13/16 1-5/16 1/2 I.D. Nominal Dimensions (Inches) O.D. Height PES-4 1 50 3 1 1-5/8 5/8 PES-5 1-1/4 25 4 1-3/8 2 5/8 PES-6 1-1/2 25 4-1/2 1-5/8 2-1/4 5/8 PES-8 2 10 7 2 2-3/4 5/8 PES-10 21/2 5 11 2-7/16 3-1/4 13/16 PES-12 3 5 14 3 3-7/8 7/8 PES-14 3-1/2 5 16-1/2 3-1/2 4-3/8 7/8 PES-16 4 2 25 4 5 7/8 308 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 309 Fittings and Accessories TYPE PET-THREADLESS-FOR RIGID CONDUIT-FEMALE-SET SCREW THREADLESS For threadless rigid conduit on all free conduit terminals such as terminating behind or within switchboards, switchgear, etc. Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) PET-2 1/2 50 1-1/2 5/8 1-1/8 5/8 7/8 PET-3 3/4 50 2 13/16 1-5/16 5/8 1-1/16 I.D. 1 Nominal Dimensions (Inches) O.D. Height I.D. 2 PET-4 1 50 3-1/2 1 1-5/8 25/32 1-11/32 PET-5 1-1/4 25 4-1/2 1-3/8 2 25/32 1-11/16 PET-6 1-1/2 25 5-1/2 1-5/8 2-1/4 25/32 1-15/16 PET-8 2 10 7-1/2 2 2-3/4 25/32 2-13/32 PET-10 2-1/2 5 12 2-7/16 3-1/4 1 2-29/32 3-17/32 PET-12 3 5 14 3 3-7/8 1-1/16 PET-14 3-1/2 5 17 3-1/2 4-3/8 1-1/16 4-1/32 PET-16 4 2 25 4 5 1-1/16 4-17/32 E10016 LISTED E10016 LISTED For use directly on thin wall conduit. Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) SPE-2 1/2 50 1-3/4 5/8 1-1/8 5/8 23/32 SPE-3 3/4 50 2-1/4 13/16 1-5/16 5/8 15/16 I.D. 1 Nominal Dimensions (Inches) O.D. Height I.D. 2 SPE-4 1 50 3-3/4 1 1-5/8 25/32 1-3/16 SPE-5 1-1/4 25 5-1/4 1-3/8 2 25/32 1-17/32 SPE-6 1-1/2 25 6 1-5/8 2-1/4 25/32 1-25/32 SPE-8 2 10 8-1/4 2 2-3/4 25/32 2-7/32 For EMT sizes 2-1/2 thru 4” use type PET. TYPE PEM A high strength resilient male bushing recommended to protect wires passing through steel cabinet walls, metal partitions and similar applications. For additional strength it is recommended this bushing be secured with type PE deep threaded female bushing. Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) PEM-2 1/2 50 1 5/8 1-1/8 5/8 PEM-3 3/4 50 1-1/2 13/16 1-5/16 5/8 25/32 I.D. Nominal Dimensions (Inches) O.D. Height PEM-4 1 50 2-1/2 1 1-5/8 PEM-5 1-1/4 25 3 1-3/8 2 25/32 PEM-6 1-1/2 25 4 1-5/8 2-1/4 25/32 PEM-8 2 10 6 2 2-3/4 25/32 PEM-10 2-1/2 5 10 2-7/16 3-1/4 1-1/16 PEM-12 3 5 14 3 3-7/8 1-1/16 PEM-14 3-1/2 5 16-1/2 3-1/2 4-3/8 1-1/16 PEM-16 4 2 21 4 5 1-1/16 E10089 309 LISTED ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 10A–17 TYPE SPE-THREADLESS-FOR EMT-FEMALE-SET SCREW 15599 Sec.10 12/9/01 11:22 AM Page 310 Fittings and Accessories TYPE PEML WITH LOCKNUT A high strength resilient male bushing recommended to protect wires passing through metal walls, partitions and similar applications. Furnished with metallic locknuts. Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) PEML-2 1/2 50 2-1/2 5/8 1-1/8 5/8 PEML-3 3/4 50 3-1/2 13/16 1-5/16 5/8 I.D. Nominal Dimensions (Inches) O.D. Height PEML-4 1 50 6 1 1-5/8 25/32 PEML-5 1-1/4 25 6-1/2 1-3/8 2 25/32 PEML-6 1-1/2 25 9 1-5/8 2-1/4 25/32 PEML-8 2 10 11 2 2-3/4 25/32 PEML-10 2-1/2 5 30 2-7/16 3-1/4 1-1/16 PEML-12 3 5 34 3 3-7/8 1-1/16 PEML-14 3-1/2 5 39 3-1/2 4-3/8 1-1/16 PEML-16 4 2 56 4 5 1-1/16 10A–18 Poly PRECISION MOLDED INSULATING BUSHINGS A rugged, high strength molded bushing for general use on rigid conduit connectors and similar installations. Listed by Underwriters Laboratories Inc. for 105° C (221° F). Meets all requirements of National Electrical Code for insulating bushings. Catalog Number Conduit Size (Inches) Carton Qty. Wt. Per Hundred (Lbs.) I.D. PM-2 1/2 100 1 19/32 1-1/16 13/32 PM-3 3/4 100 1 25/32 1-5/16 13/32 PM-4 1 50 2 1 1-5/8 1/2 PM-5 1-1/4 25 3 1-5/16 2 1/2 PM-6 1-1/2 25 3 1-17/32 2-7/32 9/16 9/16 Nominal Dimensions (Inches) O.D. Height PM-8 2 10 6 1-31/32 2-21/32 PM-10 2-1/2 5 11 2-5/16 3-5/16 5/8 PM-12 3 5 14 2-7/8 3-15/16 11/16 PM-14 3-1/2 5 22 3-5/16 4-7/16 11/16 PM-16 4 5 23 3-25/32 4-29/32 11/16 PM-20 5 2 40 4-13/16 6-3/16 31/32 PM-24 6 2 50 5-3/4 7-9/32 31/32 E25237 LISTED 310 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 311 Fittings and Accessories FIXTURE HANGERS SWIVEL SELF ALIGNING OUTLET BOX COVERS Types SA-342 and SA-42 Adalet self-aligning covers provide flexible suspension assuring plumb alignment of the lighting fixture regardless of ceiling structure or angle. Fixtures hung from these aligner covers can be hit or bumped without damage that would be caused if rigidly mounted. Catalog Number Unit Carton Qty. Standard Package Approx Wt. Std. Pkg. *SA-342 25 100 41 SA-42 25 100 50 10A–19 Made of stamped steel, these Aligner Covers are equipped with ball joint allowing the fixture to swing through an angle of 20° in any direction of the perpendicular. The SA-342 has two sets of supporting screw hole centers for 3-1/4” and 4” octagonal outlet boxes and covers are spotted for 2-3/4” mounting centers. Type SA-42 has two sets of supporting screw holes for 4” square outlet boxes and covers are spotted for 3-1/2” and 2-3/4” centers for 4” and 3-1/2” octagonal boxes. Ball tapped for 1/2” stem. SA-342 SA-42 * UL Listed E88804 311 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.10 12/9/01 11:22 AM Page 312 Sky-Tie™ — Bus-Drop Cable Clamps Supports... Cable up to 1-1/8" diameter. Uniform “lap” design of each clamp-half results in support along the entire quarter bend. Anchors... Cable for 90° angle transitions using a simple, two-piece construction of interchangeable clamp-halves. Loops... Excess cable for convenient handling and out-of-the-way storage, via the Sky-Tie™ SHD Duplex Converter. The SHD reduces the need to cut cable when machines are moved to new locations. The SHD converter simply fits between the two halves of the Sky-Tie™ SH cable clamps. Perfect For: • Machine Tools • Portable Tools • Air Lines • Other heavy-cable support applications. 10A–20 Sky-Tie™ Springs Heavy-duty Sky-Tie™ Springs insure tautness of the cable, while absorbing vibrations and shocks. Each spring slips into the Sky-Tie™ clamp at its outside bend (or, if using the SHD Duplex, the converter’s outside bend), and ties back to a structural member. Three spring models with maximum load capacities of 60, 70 and 160 pounds. Sky-Tie™ Springs Catalog Number Max. Spring Load Carton Approx. Qty. Wt. Std. Pkg. Approx. Qty. Wt. SHS-50 60 lbs. 10 2.2 50 11 SHS-75 70 lbs. 10 2.7 50 14 SHS-1125 160 lbs. 10 11 10 11 SH SHD SHS Sky-Tie™ Two-In-One Cable Clamps Catalog Number Cable OD (Inches) Typical Multi-Conductor Cable Size Carton Approx. Qty. Wt. Std. Pkg. Approx. Qty. Wt. SH-50 1/2 to 3/4 14/4 thru 8/4 10 3.5 50 SH-75 3/4 to 1-1/8 8/4 thru 3/4 or (1) 500 MCM 10 7 50 18.5 36 SH-1125 1-1/8 to 1-11/16 Special Applications 5 10 25 50 Lugs prevent nuts from turning. Keyhole slots permit assembly on cable without removal of bolts or threading of cable through fitting. Sky-Tie™ “Duplex” Component Catalog Number Cable OD (Inches) Typical Multi-Conductor Cable Size Carton Approx. Qty. Wt. Std. Pkg. Approx. Qty. Wt. SHD-50 1/2 to 3/4 14/4 thru 3/4 10 3.25 50 17.25 SHD-75 3/4 to 1-1/2 8/4 thru 3/4 or (1) 500 MCM 10 7 50 36 312 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 313 Cable Couplers Portable Cable Systems Couplers/Plugs-Receptacles Cable Couplers Identification & Application Basic nomenclature identifies the metallic shell (Plug or Socket) first, the type of contact (Male or Female) second. For switchgear or other non-cable mounted units, the letter G suffix designation is added. Example of the PLM Catalog number system is as listed: Other added options available for the coupler and catalog number identification is listed. Spare part requirements are minimized by widely interchangeable components. Suggested application of cable couplers is a plug on one end of a cable and a socket on the other end. Common usage has the socket being on the source end and the plug on the load end. PMG 415A Plug, male contacts, switchgear mount, with ground check contact. PML 415A Plug, male contacts, line mount, with ground check contact. SFL 415A Socket, female contacts, line mount, with ground check contact. SFG 415A Socket, female contacts, switchgear mounted, with ground check contact. PLM Cable Coupler Selection Guide * ADDED FEATURES * HOUSING CONTACTS MOUNTING VOLTAGE CLASS & END BELL SIZE S Socket F Female G Gear Mount Q Prefix PLM P Plug M Male L Line Mount Quick Thread style EXAMPLE double Q P M L 415 A B start Acme thread INTERLOCK COVER QUIK THREAD T Quick Turn FOR PLUG PLUG Ramp Style ONE GROUND MALE CONTACTS Blank CHECK CONTACT Standard LINE MOUNT DURA-TUBE INSULATOR Thread GROUND CHECK Fiberglass Insulator 475 or 575 EPDM (Rubber) Insulator 415 or 515 Dura-Tube 366 Continuous Shield A - One Contact Included AA - Two Contacts AAA - Three Contacts AAAA - Four Contacts B BB C D L N Interlock contacts in cover for plug Interlock contacts in cover for socket Kirklock sockets only Pan skid mount Insulation in plug cover Non-interchangeable amperage or voltage index P Padlock provision socket R Insulation in socket cover TF Teflon Insulator X Long end bell Z Beryllium contacts Applications Features Benefits • • • • • • • • • • • • • • • • • • • • Extending Portable Cables Mine Power Centers Electric Shovels, Drills, Draglines Tunneling Machines Transformer Connections Barge, Ship-Dock Applications Turbine Generators Motor Disconnect 600V-15kV to 500 Amp. • • • • Corrosion-Resistant Aluminum Electrically Tested Insulator Silver-Plated Copper Contacts Ground Check System Portable Cable Connections Switchgear or Equipment Mounting Standard Cover Included FSD Terminations Included Interlock Covers Available Filling Compounds Typical Surface Mine Physical, Electrical Protection Quick, Connect-Disconnect Provides Proper Phase Alignment Longer Coupler Life Entirely Watertight Easy Installation 11A–1 THREAD Compliance • Pennsylvania Bureau of Deep Mine Safety PORTABLE BREAKER SKID 1. Female sockets on source side of substations, line, and portable skids. 2. Male plugs on load side of skids, loader and stripper. SUBSTATION SUBSTATION HIGH WALL To Order, Provide: 1. Catalog numbers. 2. Voltage requirements. 3. Conductor sizes of phase, ground wires, and ground check wire. 4. Overall cable diameter. Also on 366 series, diameter over each phase conductor insulation. LOADER STRIPPER 313 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 314 Portable High-Voltage Cable Couplers 415, 515 EPDM Insulators — Dura-Tube SM 500 Amperes • 15,000 Volts Maximum Features Benefits • Corrosion-resistant aluminum • Superior electrical and physical protection • Rigid, non-breakable EPDM insulators • Fewer mating problems • 500 Amp contacts • Quicker installation • Portable cable mounting • Quick connect-disconnect • Switchgear or equipment mounting • Versatile application • Standard cover, stress control kit, instructions included Compound is not included and is not required up to 7,500 volts. Above 7,500 Volts and when compound is required, use COLDPOUR® Compound. Do not use asphalt compound with EPDM style couplers. Compound mandatory for 15kv. Electrical Characteristics Maximum Voltage Phase-to-Ground 1 Minute Dry Withstand AC 6 Hour Dry Withstand DC 15 Minute Dry Withstand DC Corona Extinction Level Basic Impulse Level No Compound With Compound 5.5 35.0 25.0 65.0 7.5 75.0 8.7 45.0 35.0 75.0 11.0 95.0 KV KV KV KV KV KV rms rms rms rms rms crest KV KV KV KV KV KV rms rms rms rms rms crest All tests per IEEE Standard 48-1990 Catalog Number Standard Threads Catalog Number Acme Quik-Thread Ship Wt. (lbs.) Description QSFG 415A QPMG 415A Equipment-mounted couplers Socket, Female Contacts Plug, Male Contacts 34 34 SFL 415 A PML 415 A QSFL 415A QPML 415A Line-mounted couplers 1.50-3.50 O.D. Cables Socket, Female Contacts Plug, Male Contacts 51 51 SFL 515 A PML 515 A QSFL 515A QPML 515A 3.50-4.50 O.D. Cables Socket, Female Contacts Plug, Male Contacts 53 53 SFG 415 A PMG 415 A SFL 415 A 11A–2 Options Available at Additional Cost Catalog Number Suffix –A –AA –B –BB –C –E –L –N –P –R –X –Z –TF Additional Options Ground check circuit contact (1) included Two ground check circuit contacts Cover interlock for plug Cover interlock for socket Kirk interlock (key type)–sockets only Electrolytic copper contacts–female Cover/insulator assembly for plug Non-interchangeable amperage or voltage index Padlock provision-socket Cover/insulator assembly for socket Extended end bell for larger cable sizes Beryllium contacts–male Teflon Insulator Series 415 and 515 are recommended for all existing installations where 375, 475, 575, 154 and 155 series couplers have been used and will interface with these couplers. The Q prefix 2 1/2 turn Quik-thread is suggested for new applications or those customers presently using Quik-thread applications. Quik-thread, Quick-turn and 8 pitch couplers will not interface. Note: Male/Female insulator and contact assemblies are interchangeable within coupler housings. Specify PF or SM in catalog selection or consult factory. On initial orders, one coupling wrench and one contact wrench will be required. See page 11A–9. For aluminum conductors, consult factory. 314 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 315 Couplers Teflon Insulators 415TF/515TF Portable High-Voltage Cable Couplers ADALET-PLM NOW OFFERS AN IMPROVED HIGH VOLTAGE MINING COUPLER INSULATOR SYSTEM Combining a non-tracking, easy-to-clean hydrophobic material with an internal o-ring seal between tubes. 500 AMPERES 15,000 VOLTS MAXIMUM Features • • • • • • • • • Corrosion-Resistant Aluminum Rigid, Non-Breakable TEFLON® Insulators 500 Amp Contacts Portable Cable Mounting Switchgear or Equipment Mounting Standard Cover, Stress Control Kit, Instructions Included Solid Polyester Fiberglass Flange Teflon Tubes O-ring Sealed to Flange Nylon Lock Nuts for Positive Seal SFL 415ATF Electrical Characteristics Benefits • • • • • Superior Electrical and Physical Protection Fewer Mating Problems Quicker Installation Quick Connect-Disconnect Versatile Application Maximum Voltage Phase-to-Ground 1 Minute Dry Withstand AC 6 Hour Dry Withstand AC 15 Minute Dry Withstand DC Corona Extinction Level Basic Impulse Level No Compound 5.5 kV rms 35.0 kV rms 25.0 kV rms 65.0 kV aver 7.5 kV rms 75.0 kV crest With Compound 8.7 kV rms 45.0 kV rms 35.0 kV rms 75.0 kV aver 11.0 kV rms 95.0 kV crest All tests per IEEE Standard 48-1990 Compound is NOT included and is not required up to 7,500 Volts. ABOVE 7,500 Volts and when compound is required, use COLDPOUR® Compound, Do NOT use asphalt compound. Options Available at Additional Cost Catalog Number Suffix NOTE: Male/Female insulator and contact assemblies are interchangeable within coupler housings. Specify PF or SM in catalog selection or consult factory. On initial orders, one coupling wrench and one contact wrench will be required. See page 11A–9. For aluminum conductors, consult factory. Teflon® is a registered trademark of E.I. DuPont de Nemours and Company -A -AA -B -BB -C -E -L -N -P -R -X -Z Additional Options Ground Check Circuit Contact (1) Included Two Ground Check Circuit Contacts Cover Interlock for Plug Cover Interlock for Socket Kirk Interlock (Key Type)-Sockets Only Electrolytic Copper Contacts-Female Cover/Insulator Assembly for Plug Non-Interchangeable Amperage or Voltage Index Padlock Provision-Socket Cover/Insulator Assembly for Socket Extended End Bell for Larger Cable Sizes Beryllium Contacts-Male 11A–3 Series 415 and 515 are recommended for all existing installations where 375, 475, 575, 154, and 155 series couplers have been used and will interface with these couplers. The Q prefix 2 1/2 turn QuikThread or threadless Quik-Turn is suggested for new applications or those customers presently using such couplers. Quik-Thread, Quik-Turn and 8 pitch couplers will not interface. Catalog Number and Description Catalog No. Stand. Threads Catalog No. Quik-Thread Catalog No. Quik-Turn Description Ship Wt. SFG 415ATF QSFG 415ATF TSFG 415ATF Socket, Female Contacts 34 PMG 415ATF QPMG 415ATF TPMG 415ATF Plug, Male Contacts 34 EQUIPMENT-MOUNTED COUPLERS LINE-MOUNTED COUPLERS 1.50-3.50 O.D. Cables SFL 415ATF QSFL 415ATF TSFL 415ATF Socket, Female Contacts 51 PML 415ATF QPML 415ATF TSFL 415ATF Plug, Male Contacts 3.50-4.50 O.D. Cables 51 SFL 515ATF QSFL 515ATF TSFL 515ATF Socket, Female Contacts 53 PML 515ATF QPML 515ATF TPML 515ATF Plug, Male Contacts 53 315 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 316 Cable Couplers T415, T515 Quik-Turn Application • New installations where maximum convenience and speed is required • Existing installations where abusive conditions cause thread damage Features (Quik-Turn Couplers) • 1/4 turn engagement for fast connection. • Stainless steel pin and sleeve for corrosion resistance. • Color coded orange for high visibility identification. 1 • Fully interchangeable with other threadless couplers using EPDM insulators. 2 • Spare parts common to PLM 8 pitch and Quik-Thread coupler designs. 3 4 Ratings 5 500 Amperes, 15,000 Volts Max. 6 7 8 9 10 11 Approvals Features (Common to All PLM Couplers) Pennsylvania Bureau of Deep Mines Safety – BOTE 1363-92 1 Heavy duty Ecoalube coated aluminum castings for high strength and corrosion protection. 2 Completely metal enclosed insulators, O-ring sealed. Catalog Number Quik-Turn Description 3 Rigid non-breakable DURATUBE EPDM insulator tubes eliminate mating problems. Grey color provides easy check of cleanliness. Ship Wt. (lbs.) 11A–4 TSFG 415A TPMG 415A Equipment-mounted Couplers Socket, Female Contacts Plug, Male Contacts TSFL 415A TPML 415A Line-mounted Couplers 1.50-3.50" O.D. Cables Socket, Female Contacts Plug, Male Contacts TSFL 515A TPML 515A 3.50-4.50" O.D. Cables Socket, Female Contacts Plug, Male Contacts 34 34 4 Close tolerance, silver plated contacts provide reliable connections and assured conductivity. 5 Smooth profile end bell resists snags. 6 Solid one piece flame retardant flange with O-rings on both sides insures against the entrance of moisture. 51 51 7 FSD stress relief pads provide fast, safe, dependable cable terminations within coupler housing. 53 53 8 Easy access chamber for COLDPOUR® filling compound when required. 9 Rugged cable entrance clamp and thick neoprene gasket for excellent moisture seal at cable entrance. 10 Ground check circuit contact is included. Additional contacts available. 11 Captive metal covers to keep insulators clean and dry when disconnected. Electrical Characteristics Maximum Voltage Phase-to-Ground 1 Minute Dry Withstand AC 6 Hour Dry Withstand DC 15 Minute Dry Withstand DC Corona Extinction Level Basic Impulse Level No Compound With Compound 5.5 35.0 25.0 65.0 7.5 75.0 8.7 45.0 35.0 75.0 11.0 95.0 KV KV KV KV KV KV rms rms rms rms rms crest KV KV KV KV KV KV rms rms rms rms rms crest All tests per IEEE Standard 48-1990 316 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 317 Portable High-Voltage Cable Couplers 475, 575 Polyester Fiberglass Insulator 500 Amperes • 7,500 Volts Maximum Electrical Characteristics* This series is the same as the 415 and 515 series except the insulator is polyester fiberglass rather than EPDM. COLDPOUR® compound must be ordered as a separate item. Maximum Voltage, Phase-to-Ground 15 Minute Dry Withstand D.C. 1 Minute Dry Withstand 60Hz 6 Hour Dry Withstand 60Hz Corona Extinction Level 5.5 65.0 35.0 25.0 7.5 kV kV kV kV kV rms aver rms rms rms All tests per IEEE Standard 48-1962. * Filled with compound Catalog Number Description Ship Wt. (lbs.) SFG 375 A PMG 375 A Equipment-mounted couplers Socket, Female Contacts Plug, Male Contacts 32 32 SFL 475 A PML 475 A Line-mounted couplers 1.50-3.50 O.D. Cables Socket, Female contacts Plug, Male contacts 50 50 SFL 575 A PML 575 A 3.50-4.50 O.D. Cables Socket, Female contacts Plug, Male contacts 52 52 SFL 475 A Options Available at Additional Cost –A –AA –B –BB –C –E –L –N –P –R –X –Z Additional Options Ground check circuit contact (1) included Two ground check circuit contacts Cover interlock for plug Cover interlock for socket Kirk interlock (key type)–sockets only Electrolytic copper contacts–female Cover/insulator assembly for plug Non-interchangeable amperage or voltage index Padlock provision-socket Cover/insulator assembly for socket Extended end bell for larger cable sizes Beryllium contacts–male 11A–5 Catalog Number Suffix Data Required on Order Note: Male/Female insulator and contact assemblies are interchangeable within coupler housings. • Sizes and number of ground checks • Phase conductor size Specify PF or SM in catalog selection or consult factory. • Catalog number • Overall O.D. of cable On initial orders, one coupling wrench and one contact wrench will be required. See page 11A–9. For aluminum conductors, consult factory. • Sizes and number of ground wires • Voltage class 317 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 318 Portable High-Voltage Cable Couplers 366 EPDM Insulators — Continu-Shield SM 200 Amperes • 6,600 Volts Maximum Features Benefits • Corrosion-resistant aluminum • No compound required • Compact design • Small size, lightweight • Unbreakable molded EPDM insulators • More economical • Continuous shield design • Better fault protection • Airtight insulator connection • Better electrical characteristics • Double start Acme thread Electrical Characteristics Maximum Voltage, Phase-to-Ground 1 Minute Dry Withstand AC 6 Hour Dry Withstand AC 15 Minute Dry Withstand DC Corona Extinction Level Basic Impulse Level 3.8 35.0 25.0 65.0 7.5 75.0 kV kV kV kV kV kV rms rms rms aver rms crest All tests per IEEE Standard 48-1962 Catalog Number Description SFL 366A Ship Wt. (lbs.) SFG 366 A PMG 366 A Equipment-mounted couplers Socket, Female Contacts Plug, Male Contacts 11 11 SFL 366 A PML 366 A Line-mounted couplers Socket, Female contacts Plug, Male contacts 17 17 11A–6 Options Available at Additional Cost Catalog Number Suffix –A –AA –BL –BBR –P –C Additional Options Ground check circuit contact (1) included Two ground check circuit contacts Cover interlock for plug Cover interlock for socket Padlock provision-socket Kirk interlock (keytype) sockets only Data Required on Order • Catalog number • Sizes and number of ground wires Note: On initial orders, one coupling wrench will be required. See page 11A–9. • O.D. over insulation of phase conductors • Voltage class Maximum diameter over phase insulation .840". • Sizes and number of ground checks Maximum conductor size 4/0 Awg. • O.D. of cable over jacket For use on copper cable only. For aluminum cables, consult factory. • Phase conductor size and type • Class of stranding • For unshielded cables, order kit #A1746 318 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 319 Other Portable Cable Products PCF, WACS Cable Strain Relief PCF Flange-mounted cable strain reliefs provide gasket-sealed, strain-relief entrance of portable cables into metal-clad equipment. All hardware, fasteners and gaskets are included. Type PCF and PCFL Round Cables Catalog Number PCF PCF PCF PCF PCF PCF PCF PCF PCF PCF Cable Range 175 200 225 250 275 300 325 350 375 400 1.50-1.75 1.75-2.00 2.00-2.25 2.25-2.50 2.50-2.75 2.75-3.00 3.00-3.25 3.25-3.50 3.50-3.75 3.75-4.00 9/16 DIA. 6 HOLES EQUALLY SPACED 41/2 ID 6 1/8 BC 7 1/4 DIA. MOUNTING DIMENSIONS For Blind Tap mounting holes add suffix “L”. On all orders Cable Diameter must be specified. Wire Armored Cable Support WACS Type WACS Cable Supports are designed for use as supports for wire armored cable in borehole or vertical wireways. In such applications, the cables are usually wire armored and supported at the top by the wire armor. Single support systems are particularly useful for primary distribution in high-rise buildings where permissible. In accessible locations the cable may be clamped to the side wall in addition to the top support. The supports should be chosen first on the basis of weight to be supported and secondly, on diameter of cable. Fabricated from steel plate and hot-dip galvanized. Order by catalog number and include description and O.D. of cable. C DIA CONDUCTOR EYEBOLT FOR CONVENIENCE IN PLACING CABLE 11A–7 INSULATION LEAD SHEATH JUTE B DIA MAX. DIA OF CABLE GALVANIZED STEEL WIRE APPLIED 25 TO 50 FEET APART WHEN CABLE IS SUPPORTED ONLY AT THE TOP. A DIA Discount Schedule A Dimensions (Inches) Catalog Number Weight Capacity (lbs.) Max. Cable O.D. A Three Plate Support B C WACS238 WACS288 WACS338 WACS388 WACS330 WACS380 WACS420 7500 7500 7500 7500 10000 10000 10000 2.37 2.87 3.37 3.87 3.37 3.87 4.25 9.75 9.75 9.75 9.75 12.00 12.00 12.00 2.60 3.10 3.60 4.10 3.60 4.10 4.50 3.00 3.50 4.00 4.50 4.00 4.50 4.90 Ship Weight (lbs.) 50 50 50 50 80 80 80 319 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 320 Other Portable Cable Products CP, PCK COLDPOUR® Compound* CP Compound filling can prevent condensation and provide added protection in wet locations. Asphaltic compounds cannot be used with EPDM insulations. For those customers who may wish to use compound, ADALET offers a COLDPOUR® compound which does not require heating for installation or removal. Suitable for all couplers. No shrinkage or waste. Approximately 2-hour gel time. Catalog Number Shipping Weight (lbs.) Description CP-40 1 5/8 gal. 2-part mix for one LINE mount or two GEAR mount couplers, Series 415 or 475 coupler. 13 CP-50 1 7/8 gal. 2-part mix for one LINE mount, Series 515 or 575 coupler 14 CP-55 2 1/4-gal. 2-part mix for one Suffix-X LINE mount coupler with extended end bell. 24 *Shelf life, 6 mos. Should be installed at normal room temperature. Coupler Contact Insulation Cleaning Kit Dirt contamination can cause electrical failures. The mating contact insulators can be efficiently cleaned with the PCK100 Cleaning Kit. Kit consists of 16-oz. aerosol can of non-flammable electrical parts cleaner, bristle brush, two white wiping cloths and polyethylene glove. Ozone-safe spray can contains no fluorocarbons. Catalog Number PCK-100 Description Cleaning Kit Shipping Weight (lbs.) 1 1/2 11A–8 Replacement Coupler Insulators Insulator kits to replace polyester fiberglass and cone seal style insulators Complete package includes rigid, unbreakable insulator tubes with flame-retardant flange and all necessary conductor and insulation shield terminating material except contacts. May be used with existing PLM Couplers. Add COLDPOUR® for 15kV applications. Catalog Number K K K K 415 415 415 415 F M FG MG Shipping Weight (lbs.) Description For For For For female line plugs or sockets male line plugs or sockets female gear-mount plugs or sockets male gear-mount plugs or sockets 10 10 8 8 320 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 321 Other Portable Cable Products Type QT Conversion Kits QT Any cable coupler line mount or gear mount may be converted to Acme double start Quik-Thread style or Quik-Turn style. These style couplers will not mate with standard 8 pitch thread couplers; therefore, it is necessary to change the socket body, lock ring, and covers. Select the correct conversion plug or socket kit from the table below. Kits include only the thread parts which must be changed, plus new screws and gaskets. Quik-Thread coupler rings are color-coded green to provide positive identification. Quick-Turn coupler rings are color-coded orange. Conversion kits should be applied to all couplers on any single cable system. Acme Thread Parts Furnished QKS-8 Description QKP-8 TKP-8 Plug cover and lock ring Replacement for plug-style couplers. Includes plain cover (without drilling for pilot or ground contacts). QKP-M/F-8 TKP-M/F-8 Plug cover (drilled for pilot and ground contacts) and lock ring Replacement for plug-style couplers. Includes cover drilled for ground and pilot contacts (male or female). Customer to use existing contacts. QKP-M/F-15 TKP-M/F-15 Plug cover (drilled for pilot and ground contacts and for cover insulator assembly) and lock ring Replacement for plug-style couplers. Includes cover drilled for ground and pilot contacts (male or female) and for cover insulator assembly. Customer to use existing contacts and cover insulator assembly. QKS-8 TKS-8 Socket cover and socket body Replacement for socket-style couplers. Includes plain cover (without drilling for pilot or ground contacts). QKS-M/F-8 TKS-M/F-8 Socket cover ring and socket body Replacement for socket-style couplers. Includes cover ring to be used with existing cover. Customer to use existing contacts. QKS-M/F-15 TKS-M/F-15 Socket cover ring and socket body Replacement for socket-style couplers. Includes cover ring to be used with existing cover and cover insulator assembly. Customer to use existing contacts. 11A–9 Catalog Number QKP-8 Coupler Wrenches Catalog Number Shipping Weight (lbs.) Description WR Contact wrench for 415, 515, 475, 575 series 1 C-1008 Coupling wrench (Aluminum) for 415, 515, 475, 575 series 1 C-1008-S Coupling wrench (Steel) for 415, 515, 475, 575 series 3 C-1678-S Coupling wrench (Steel) for 366 series 3 CONTACT WRENCH COUPLING WRENCH 321 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 322 Other Portable Cable Products Skids Adalet Cable Couplers — Surface Mining Application Because of operational convenience, economics, and added safety, many surface mining operations use Adalet Couplers in conjunction with handling trailing cables. Adalet Couplers are designed so that the first circuit to open and the last to close is the ground check, so that the circuit breakers cannot be operated until the ground and phase contacts are connected. Furthermore all live parts are enclosed in the housing. Thus couplers provide a compact, safe, watertight, and dust-tight connection. For rugged surface conditions, Adalet has designed features and products to utilize couplers and provide rapid, safe means for handling trailing cables. For high inrush currents associated with surface mining equipment, Adalet provides high conductivity split copper, silver plated, male contacts with pressure maintaining elastomeric inserts. Female contacts are silver plated high conductivity copper. QPMG415A CABLE CABLE SKID SUBSTATION STRIPPER QSFL415A QPMG ON SUBSTATION, SKIDS, STRIPPER. QSFL (LESS FEET) ON BOTH CABLE ENDS. 11A–10 Type Q – Quik-Thread Type EP-1 Coupler Skid Coupling rings with double start Acme thread permits couplers to be connected or disconnected in only 2 1/2 turns. Special hardened and permanently lubricated threads are recessed from the end of the coupler to prevent damage and eliminate clogging and seizing. Adalet Quik-Thread Style Couplers are color coded green to provide positive identification. For moving cables and support of cable couplers. Couplers are mounted on a turntable positioned on skid. A steel cable support in the center of the sled supports cable loops which are fed off the back of the skid as the equipment moves forward. Ten inch high posts on each back corner of skid provide a tie point for pulling loops when picking up cables, and prevent the cables from sliding under the skid. Type JB-1 Coupler Box Compact, rugged steel plate box protects couplers from rock fall and offers double environmental protection for electrical connection. Fast connect-disconnect even in the most adverse conditions. The coupler is positioned on mounting pins, inside the skid house. For removal, simply raise cover and lift out coupler and cable. Mounted on skids, the skid house is equipped with tow hooks providing rapid means of moving skid, coupler & cable. Type JB Skids For cable handling ease and for two to three feeder junction boxes. Normally wired with 1, 2, or 3 sockets for outgoing power and one plug incoming. May be utilized as illustrated above. Type HB Sleds Same as above, mounted on high runners for clearing rubble. 322 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 323 Other Portable Cable Products Skids Lowboy Skids 2-way, 3-way or 4-way Factory-wired for 15 kV–500 ampere service includes ground and ground check wiring. Lowboy skids are used for two-way, threeway or four-way connections of portable cables. Boxes are wired internally and compound-filled. Prices do not include couplers – order separately. Catalog Number LB-2 LB-3 LB-4 Application 2-way 3-way 4-way Hi-Boy Sleds 2-way, 3-way or 4-way Factory-wired for 15 kV–500 ampere service includes ground and ground check wiring. Hiboy sleds offer tubular runners suitable for clearing rubble or keeping couplers out of mud, water or snow. Boxes are wired internally and compound-filled. Prices do not include couplers – order separately. Catalog Number HB-2 HB-3 HB-4 Application 2-way 3-way 4-way JB-1 Coupler Box • 3/16” steel plate fabrication • Compact design • Skid-mounted • Cable entry seal and support • Painted safety yellow • Hinged cover with provision for padlock Benefits • Maximum physical protection of coupler • Protects coupler from environment • Simplifies cable movement • Labor and material cost savings when compared with highvoltage connection boxes 11A–11 Features 24" 24" 72" EP-1 Coupler Skid Features • 1/2” steel plate construction • Compact design • Turntable coupler mount • Steel cable support • Protects cable from sharp bends Benefits • Rugged design prevents couplers from snagging when moving equipment in rough terrain • Simplifies the movement of trailing cables 16" • Reduced cable handling downtime • Offers superior electrical features of using cable couplers 24" 72" 323 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 324 Systems Voltage Selection In many mining systems the original and replacement costs of cable can become a major item of expense. From an economic standpoint, the distribution voltage should be as high as possible. At 7500 volts, the cost of cables is approximately half of the cost of cables required to handle the same load at 2300 or 4160 volts with very little extra cost on the other electrical equipment. 13.2kV equipment is considerably more expensive than 7500 volt equipment, but in boreholes, or where long cable runs are necessary in open pit mines, the use of 15kV cables and couplers can be advantageous. TYPICAL SYSTEM FOR A-C POWER IN DEEP MINING 11A–12 Ground Check and Key Interlock Methods With a total of four pilot wire contacts available, the Adalet Coupler is adaptable to any presently used ground check system. In addition to the electrical interlock (ground check system), mechanical key type locks may be used to insure no voltage disconnection of couplers. Coupler Covers SCHEMATIC OF TYPICAL GROUND CHECK SYSTEM STANDARD WITH PILOT AND GROUND CONTACTS WITH INSULATOR, PILOT AND GROUND CONTACTS The Adalet Coupler is furnished with the Standard Cover. This prevents moisture and contamination from coming in contact with the coupler insulator and contacts. When it is desired to have the Cover equipped with a Pilot contact and a Ground contact, add the suffix letter “B” to the catalog number for Plug style coupler and letter “BB” for Socket style coupler. With these contacts installed it is then possible to check the integrity of the Ground Check circuit. The covers are available with an insulator, pilot contact, and ground contact. It is then possible to energize the cable without the coupler being connected to another coupler. Add the suffix letters “BL” to the catalog number for Plug style coupler and letters “BBR” for Socket style coupler. 324 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 325 Couplers PLM: The Leading Coupler in the Mining Industry A History Use PLM products began in 1951 as a supplier of cable accessories for high voltage cables. Although Cable Couplers had been used in the mining industry, it was not until 1957 when requirements began to develop for voltages higher than 5kV and Amperages greater than 200 Ampere that the first 7.5kV 500 AMP Coupler was developed by PLM Products. Published test values backed by a high voltage laboratory and continuous innovations have kept PLM Products, now known as Adalet, as a world leader of cable couplers. Couplers have been utilized in underground, strip, and pit operations on every continent in the world, and for coal and hard rock mining operations of every type. Adalet Cable Couplers provide safe, convenient means for connecting portable cable rated up to 15,000 volt and up to 500 Amperes, copper or aluminum conductor to mining equipment, electric shovels, draglines, loaders, barges, tunneling machines, portable substations, portable junction boxes, or for joining lengths of high voltage cables. Housings are of rugged, corrosion resistant cast aluminum providing high strength with light weight. Thorough gasketing makes the coupler entirely watertight. Tight fitting covers for plug and socket, protect contacts and insulators from moisture when disconnected. Design From the beginning, PLM designed Couplers to standards subsequently incorporated into mine safety codes in the United States. All PLM Couplers are completely metal enclosed with the outer shell grounded to the ground wires in the cable. Couplers are designed so that the first contact to make and last to break is the ground contact. With ground check circuits the Coupler ground check circuit is the last to make and first to break. The ground contact is also grounded to the housing assuring the operator that the Coupler is grounded. Positive thread engagement of the metal housing prevents accidental disconnecting and insures proper opening and closing sequence. For further safeguard, optional electrical and mechanical (key type) systems are available. Other Couplers Available Upon Request Note: Male/Female assemblies are interchangeable within housings. Specify PF or SM or consult factory. 11A–13 All additional options are available for the above coupler. 325 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A 12/9/01 11:24 AM Page 326 Couplers Dimensional Data 11A–14 326 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 327 Indoor Termination Kits 5 - 35 kV For Use on Solid Dielectric Cable Each indoor kit includes material to make three single- or one three-conductor termination. Kit includes three FSD pads, high voltage tape, abrasive cloth and instructions. Catalog No. Cable Range FSD FSD35 FSDS35* #8–600MCM #1–1000MCM #1–1000MCM Voltage Application 5kV(100%)–25kV(100%) 25kV(133%)–35kV(100%) 25kV(133%)–35kV(100%) * Silicone overwrap for contaminated areas – indoor only. APPLICATION OF COVER TAPE INSTALLATION OF SINGLE WRAP STRESS CONTROL PAD Outdoor Termination Kits 5 kV - 25 kV For Use on Solid Dielectric Cable Catalog No. FSDS1 FSDS2 Cable Range #8–600MCM #8–600MCM 11A–15 Each outdoor kit includes material to make three single- or one three-conductor termination. Kit includes three FSD pads, high voltage tape, abrasive cloth, silicone tape, PVC all-weather tape and instructions. Voltage Application 5kV(100%)–15kV(100%) 15kV(133%)–25kV(100%) Grounding Kits & Pads Catalog No. FSDP3 FSDP35 FSD35* Cable Range 3 Extra Pads 3 Extra Pads 3 Extra Pads Voltage Application 5kV(100%)–25kV(100%) 25kV(133%)–35kV(100%) 25kV(133%)–35kV(100%) 327 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 328 PowerSpec™ Type PS Description Use where jacketed metal clad (MC) cable is installed in a non-hazardous or Division 2 area when sealing is not required. The connector is hexagonally designed for easy wrenching with a minimal overall length. The connector is UL listed according to UL 514B and does not require any disassembly to install. Features Fast, simple installation 360° grounding system provides superior conductivity Durable seal prohibits cable twisting or pull-out Applications For terminating TECK and jacketed Metal Clad cable. For vertical or horizontal runs. Watertight (UL-50 listed as a Type 4 cable fitting) Compact design Lightweight and corrosion resistant Certifications Material/Finish Applicable Standard Meets UL standard for raintight armored cable fitting. Body, Nut: Copper-Free Aluminum Flange Gasket, Grommet: Neoprene PowerSpecX (Class I, Div. 1 and 2, Haz. Locations) Armor Stop: Phenolic Type PSX Description Use where jacketed MC cable is installed in a Class I, Division 1 area or a Class I, Division 2 area when sealing is required, i.e. enclosures containing arcing or sparking devices. The connector is hexagonally designed for easy wrenching with a minimal overall length. An epoxy type sealing compound is used and the connector is UL listed according to UL 2225. Spring: Phosphur Bronze Standard Sizes Applications Terminates and seals jacketed continuous corrugated MC cable in Class I, Div. 1 and 2 and TECK and jacketed interlocked MC cable in Class I, Div. 2 locations. For vertical or horizontal runs. Provides seal for cable core where armor is removed and between the jacket and armor. .55” - 2.18” 11A–16 PowerSpec for ordinary locations, PowerSpecX for hazardous locations there’s one suited for your application Certifications power plants Class I, Groups A, B, C, D paper mills Class II, Groups E, F, G oil refineries Applicable Standard Meets NEC Sec. 501-5(e) requirements for sealing of MC cable in Class I, Div. 1, and 2 hazardous locations. Also meets UL standards for rain tight fitting in hazardous locations. offshore drilling platforms waste treatment facilities chemical plants 328 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/11/01 6:13 PM Page 329 Catalog Number Diameter Over Jacket Diameter Over Armor Maximum Cable Core Diameter Conduit Size Fitting O.D. Length Overall Ship Weight (lbs.) min. max. min. max. PS-065-05 0.55” 0.65” 0.45” 0.56” 0.56” 1/2” 1 5/8” 2 1/6” 1/4 PS-075-05 0.65” 0.75” 0.55” 0.66” 0.56” 1/2” 1 5/8” 2 1/6” 1/4 PS-085-05 0.75” 0.85” 0.65” 0.76” 0.56” 1/2” 1 5/8” 2 1/6” 1/4 PS-100-07 0.85” 1.00” 0.72” 0.90” 0.82” 3/4” 2” 2 3/16” 1/3 PS-115-07 1.00” 1.15” 0.87” 1.05” 0.82” 3/4” 2” 2 3/16” 1/3 PS-125-10 1.13” 1.25” 1.00” 1.15” 1.00” 1” 2 3/16” 2 7/16” 1/2 PS-138-10 1.25” 1.38” 1.12” 1.28” 1.00” 1” 2 3/16” 2 7/16” 1/2 PS-150-12 1.33” 1.50” 1.23” 1.40” 1.33” 1 1/4” 2 7/8” 2 7/8” 2/3 PS-168-12 1.50” 1.68” 1.40” 1.58” 1.33” 1 1/4” 2 7/8” 2 7/8” 2/3 PS-183-15 1.68” 1.83” 1.58” 1.73” 1.61” 1 1/2” 3 1/4” 3 5/8” 1 PS-200-15 1.83” 2.00” 1.73” 1.90” 1.61” 1 1/2” 3 1/4” 3 5/8” 1 PS-218-15 2.00” 2.18” 1.90” 2.08” 1.61” 1 1/2” 3 1/4” 3 5/8” 1 Maximum Cable Core Diameter Conduit Size Fitting O.D. Length Overall Ship Weight (lbs.) Catalog Number Diameter Over Jacket Diameter Over Armor min. max. min. max. PSX-065-05 0.55” 0.65” 0.45” 0.56” 0.56” 1/2” 1 5/8” 2 3/4” 5/8 PSX-075-05 0.65” 0.75” 0.55” 0.66” 0.56” 1/2” 1 5/8” 2 3/4” 5/8 PSX-085-05 0.75” 0.85” 0.65” 0.76” 0.56” 1/2” 1 5/8” 2 3/4” 5/8 PSX-100-07 0.85” 1.00” 0.72” 0.90” 0.82” 3/4” 2” 3 1/8” 7/8 PSX-115-07 1.00” 1.15” 0.87” 1.05” 0.82” 3/4” 2” 3 1/8” 7/8 PSX-125-10 1.13” 1.25” 1.00” 1.15” 1.00” 1” 2 3/16” 3 1/2” 1 PSX-138-10 1.25” 1.38” 1.12” 1.28” 1.00” 1” 2 3/16” 3 1/2” 1 PSX-150-12 1.33” 1.50” 1.23” 1.40” 1.33” 1 1/4” 2 7/8” 4 1/8” 1 1/4 PSX-168-12 1.50” 1.68” 1.40” 1.58” 1.33” 1 1/4” 2 7/8” 4 1/8” 1 1/4 PSX-183-15 1.68” 1.83” 1.58” 1.73” 1.61” 1 1/2” 3 1/4” 4 11/16” 1 3/4 PSX-200-15 1.83” 2.00” 1.73” 1.90” 1.61” 1 1/2” 3 1/4” 4 11/16” 1 3/4 PSX-218-15 2.00” 2.18” 1.90” 2.08” 1.61” 1 1/2” 3 1/4” 4 11/16” 1 3/4 11A–17 PowerSpec™ To Order: Select fitting based on diameter over jacket and armor by using the table above. For locknut and bushing, add suffix LB. 329 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 330 Fittings for Metal Clad Cables Jacket over Armor Features/Benefits: • Slip - on design with no disassembly for easy installation • Neoprene bushing for raintight seal • Locknuts, bushings and flange gasket included – no additional materials to purchase • Flange gasket prevents moisture penetration through threads • Made from copper-free aluminum alloy for corrosion resistance • Fits broad range – .351-4.62 cable O.D. C Application: • For terminating metal clad cable D Certification: A B Class II To Order: Determine satisfactory fit by checking cable dimensions A and B. If cable dimensions do not fall within acceptable range, consult factory. E Dimensions (Inches) 11A–18 A B C D E Catalog Number Dia. Over Jacket Min. Max. Max. Cable Core Dia. Conduit Size Fitting O.D. Length Overall JAG JAG JAG JAG JAG JAG 45-05 55-05 65-05 75-05 85-05 95-05 .35 .45 .55 .65 .75 .85 .45 .55 .65 .75 .85 .95 .61 .61 .61 .61 .61 .61 1 JAG JAG JAG JAG 99-07 107-07 113-07 121-07 .85 .92 .98 1.07 .99 1.07 1.13 1.21 .81 .81 .81 .81 3 JAG 112-10 JAG 125-10 JAG 138-10 1.00 1.12 1.22 1.12 1.25 1.38 JAG JAG JAG JAG 138-12 156-12 174-12 188-12 1.28 1.38 1.56 1.74 JAG JAG JAG JAG 174-15 188-15 200-15 218-15 JAG JAG JAG JAG /2 /2 1 /2 1 /2 1 /2 1 /2 1 1 1 1 1 1 /4 /4 3 /4 3 /4 1.00 1.00 1.00 1 1 1 1.38 1.56 1.74 1.88 1.25 1.25 1.25 1.25 1 1 1 1 1 1.60 1.74 1.88 2.00 1.74 1.88 2.00 2.18 1.63 1.63 1.63 1.63 1 1 1 1 1 219-20 236-20 247-20 261-20 2.05 2.19 2.35 2.47 2.19 2.36 2.47 2.61 2.09 2.09 2.09 2.09 2 2 2 2 JAG 263-25 JAG 280-25 JAG 296-25 2.46 2.62 2.80 2.63 2.80 2.96 2.49 2.49 2.49 JAG JAG JAG JAG JAG 297-30 311-30 327-30 343-30 359-30 2.80 2.95 3.10 3.26 3.42 2.97 3.11 3.27 3.43 3.59 JAG 375-35 JAG 392-35 JAG 412-35 3.52 3.75 3.90 JAG JAG JAG JAG 4.05 4.20 4.34 4.43 423-40 437-40 451-40 462-40 2 2 2 2 2 2 1 /4 /4 1 /4 1 /4 1 /4 1 /4 1 1 1 2 2 2 2 2 2 2 2 5 /8 /4 1 /4 1 /4 1 1 1 2 3/8 2 3/8 2 3/8 3 1/16 3 1/16 3 1/16 1 /4 /4 1 /4 1 /4 2 2 2 2 7 /8 /8 7 /8 7 /8 3 3 3 3 3 /8 /8 3 /8 3 /8 2 3 2 /2 /2 1 /2 1 /2 3 3 3 3 1 /4 /4 1 /4 1 /4 4 4 4 4 1 /16 /16 1 /16 1 /16 1 1 1 1 4 4 4 4 4 4 4 4 5 /16 /16 5 /16 5 /16 1 1 1 1 2 1/2 2 1/2 2 1/2 4 23/32 4 23/32 4 23/32 5 7/16 5 7/16 5 7/16 2 1/2 2 1/2 2 1/2 3.11 3.11 3.11 3.11 3.11 3 3 3 3 3 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3 3.75 3.92 4.12 3.61 3.61 3.61 3 1/2 3 1/2 3 1/2 5 11/16 5 11/16 5 11/16 5 13/16 5 13/16 5 13/16 3 1/4 3 1/4 3 1/4 4.23 4.37 4.51 4.62 4.11 4.11 4.11 4.11 4 4 4 4 6 6 6 6 5 5 5 5 3 3 3 3 1 3 1 1 /8 /8 5 /8 5 /8 5 /8 5 /8 Ship Wt. (Lbs.) 5 5 7 1 /32 3 /32 3 /32 3 /32 3 /32 3 /32 /32 3 /32 3 /32 3 3 1 5 /4 3 /4 3 /4 3 /4 3 /4 3 /16 /16 13 /16 13 /16 13 13 /4 /4 1 /4 1 /4 1 /4 1 /4 /3 /3 1 /3 1 /3 /2 /2 1 /2 1 /3 /3 2 /3 2 /3 GLAND NUT PRESSURE RING /2 /2 1 /2 1 /2 1 1 NEOPRENE BUSHING GROUNDING SLEEVE ARMOR STOP /2 /2 1 /2 1 /2 1 1 JAG BODY GROUND SCREW FLANGE GASKET LOCKNUT INSULATING BUSHING 330 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 331 Fittings for Metal Clad Cables Unjacketed Armor Dry Location Features/Benefits: • Wide armor range – sizes on .200 intervals • Raised boss in strap offers excellent pullout protection • Copper-free aluminum for corrosion resistance and suitability with aluminum or galvanized steel armor Certifications: Note: For use with Cable O.D. over armor To Order: Select fitting based on diameter over armor Application: For terminating metal clad cable with unjacketed armor in dry locations Dimensions (Inches) For Use With Cable O.D. Over Armor Min. Max. A B C Conduit Size D G H-J Ship Wt. (Lbs.) AC6 .45 .64 .65 .40 3 /4 1 3/8 7 /8 1 3/8 1 AC8 .65 .84 .85 .60 1 1 13/16 1 1/8 1 11/16 1 AC10 AC12 .85 1.05 1.04 1.24 1.05 1.25 .80 1.00 1 /4 1 1/4 1 /8 2 1 /8 1 1/4 2 2 1 AC14 1.25 1.44 1.45 1.20 1 1/2 2 1/16 1 5/16 2 5/16 3 AC16 AC18 1.45 1.65 1.64 1.84 1.65 1.85 1.40 1.60 2 2 2 /8 2 3/8 1 /2 1 1/2 2 /8 2 5/8 1 1/2 1 1/2 AC20 AC22 1.85 2.05 2.04 2.24 2.05 2.25 1.80 2.00 2 1/2 2 1/2 2 5/8 2 5/8 1 5/8 1 5/8 3 1/4 3 1/4 1 3/4 1 3/4 AC24 AC26 AC28 2.25 2.45 2.65 2.44 2.64 2.84 2.45 2.65 2.85 2.20 2.40 2.60 3 3 3 2 3/4 2 3/4 2 3/4 1 3/4 1 3/4 1 3/4 3 3/4 3 3/4 3 7/8 2 2 2 AC30 AC32 AC34 2.85 3.05 3.25 3.04 3.24 3.44 3.05 3.25 3.45 2.80 3.00 3.20 3 1/2 3 1/2 3 1/2 3 1/8 3 1/8 3 1/8 2 2 2 4 7/16 4 3/8 4 9/16 2 3/4 2 3/4 2 3/4 AC36 3.45 3.64 3.65 3.40 4 3 1/8 1 15/16 5 1/8 3 AC38 3.65 3.84 3.85 3.60 5 3 1/4 2 1/16 6 4 AC40* 3.85 4.04 4.05 3.80 5 3 /16 2 /8 6 4 1/2 AC42* 4.05 4.24 4.25 4.00 5 3 1/4 2 1/4 6 1/8 4 1/2 AC44* 4.25 4.44 4.45 4.20 5 3 /4 2 /4 6 /8 4 1/2 AC46* 4.45 4.64 4.65 4.40 5 3 1/4 2 1/4 6 1/8 4 1/2 AC48* 4.65 4.84 4.85 4.60 5 3 /4 2 /4 6 /8 4 1/2 1 7 1 3 1 5 1 1 1 /2 /2 1 1 /2 1 5 1 /2 1 /4 11A–19 Catalog Number *CSA only LOCKNUT STRUCTURE C = THREAD INSULATING BUSHING GLAND ARMOR STRAP J B A H G D 331 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 332 Fittings for Metal Clad Cables Jacket under Armor Features/Benefits: • Clamping action ensures a positive mechanical and ground connection without damage to cable construction • Fits broad armor range – sizes on .200” intervals • Raised boss in strap offers excellent pull out protection • Copper-free aluminum alloy for corrosion resistance and suitability with aluminum or galvanized steel armor • Gland provides watertight cable seal in all positions Certification: Note: For use with cable O.D. over armor To Order: Select fitting based on diameter over bare armor Application: For terminating metal clad cable with jacket under armor Dimensions (Inches) A B C Conduit Size D G H-J 11A–20 Catalog Number Dia Over Armor Min. Max. Ship Wt. (Lbs.) ACS6 ACS8 .45 .65 .64 .84 .65 .85 .50 .70 3 /4 1 2 1/2 3 7 /8 1 1/8 1 1/2 2 1 1 ACS10 ACS12 ACS14 .85 1.05 1.25 1.04 1.24 1.44 1.05 1.25 1.45 1.10 1.10 1.35 1 1/4 1 1/4 1 1/2 3 1/16 3 5/16 3 3/8 1 1/8 1 1/4 1 5/16 2 1/4 2 1/4 2 3/8 1 1/2 1 1/2 1 1/2 ACS16 ACS18 1.45 1.65 1.64 1.84 1.65 1.85 1.70 1.70 2 2 3 3/4 3 3/4 1 1/2 1 1/2 3 1/16 3 1/16 1 3/4 1 3/4 ACS20 ACS22 1.85 2.05 2.04 2.24 2.05 2.25 2.12 2.12 2 1/2 2 1/2 4 3/8 4 3/8 1 5/8 1 5/8 3 1/2 3 1/2 2 1/2 2 1/2 ACS24 ACS26 ACS28 2.25 2.45 2.65 2.44 2.64 2.84 2.45 2.65 2.85 2.75 2.75 2.75 3 3 3 4 1/2 4 1/2 4 1/2 1 3/4 1 3/4 1 3/4 4 3/16 4 3/16 4 3/16 3 3 3 ACS30 ACS32 ACS34 2.85 3.05 3.25 3.04 3.24 3.44 3.05 3.25 3.45 3.30 3.30 3.30 3 1/2 3 1/2 3 1/2 4 7/8 4 7/8 4 7/8 2 2 2 4 11/16 4 11/16 4 11/16 4 4 4 ACS36 3.45 3.64 3.65 3.50 4 5 1/8 1 15/16 5 1/4 5 ACS38 ACS40 ACS42 ACS44 ACS46 ACS48 3.65 3.85 4.05 4.25 4.45 4.65 3.84 4.04 4.24 4.44 4.64 4.84 3.85 4.05 4.25 4.45 4.65 4.85 3.85 3.85 4.44 4.44 4.44 4.44 5 5 5 5 5 5 5 5 5 5 5 5 2 2 2 2 2 2 6 6 6 6 6 6 6 6 6 6 6 6 /2 /8 3 /8 3 /8 3 /8 3 /8 1 3 /16 /8 1 /4 1 /4 1 /4 1 /4 1 1 /16 /16 9 /16 9 /16 9 /16 9 /16 9 9 GASKET BASE GLAND A H PRESSURE RING 1 STRUCTURE LOCKNUT C = CONDUIT SIZE INSULATING BUSHING ARMOR STRAP J /2 /2 1 /2 1 /2 1 /2 1 /2 1 B G D GASKET 332 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 333 Cord Grip Fittings (Straight Body) Note: Consult factory for alternate materials (i.e., stainless steel) Features/Benefits: • Aluminum body and nut for exceptional corrosion resistance • Tapered rubber bushing (grommet) provides raintight, dust-tight seal and provides resistance to cutting oils, age hardening, compression set and normal temperature extremes • Anti-friction washer is supplied between the nut and bushing for ease in compression • Machine cut threads prevent cross threading, ensure smooth compression and watertight make-up in conduit hubs • Mesh option available in most sizes for additional support Applications: For terminating cable in conduit hubs or knock-outs and for providing relief from strain on cable Certifications: CGP (Straight Body) Cable Range (Inches) Catalog Number Cord Grip Only /2 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 .125-.188 .188-.250 .250-.312 .312-.375 .375-.438 .438-.500 .500-.562 .562-.625 CGP CGP CGP CGP CGP CGP CGP CGP 2188* 2250 2312 2375 2438 2500 2562 2625 /4 /4 3 /4 3 /4 3 /4 .438-.562 .500-.625 .562-.688 .625-.750 .688-.812 CGP CGP CGP CGP CGP 3562 3625 3688 3725 3812 1 1 3 3 1 1 1 1 1 1 1 .438-.562 .500-.625 .562-.688 .625-.750 .688-.812 .750-.875 .812-.938 CGP CGP CGP CGP CGP CGP CGP 4562 4625 4688 4750 4812 4875 4938 Catalog Number Cord Grip with Mesh Conduit Size (Inches) – CGP CGP CGP CGP CGP CGP CGP 2250-M 2312-M 2375-M 2438-M 2500-M 2562-M 2625-M CGP CGP CGP CGP 3562-M 3625-M 3688-M 3725-M – CGP CGP CGP CGP CGP CGP CGP 4562-M 4625-M 4688-M 4750-M 4812-M 4875-M 4938-M Cable Range (Inches) Catalog Number Cord Grip Only Catalog Number Cord Grip with Mesh – 11/4 11/4 11/4 11/4 11/4 .750-.875 .875-1.000 1.000-1.125 1.125-1.250 1.250-1.375 CGP CGP CGP CGP CGP 5875 51000 51125 51250 51375 11/2 11/2 11/2 11/2 11/2 11/2 .750-.875 .875-1.000 1.000-1.125 1.125-1.250 1.250-1.375 1.312-1.438 CGP 6875 CGP 61000 CGP 61125 CGP 61250 CGP 61375 CGP61438 CGP 61000-M CGP 61125-M CGP 61250-M CGP 61375-M CGP61438-M 2 2 2 2 1.250-1.375 1.438-1.562 1.562-1.688 1.688-1.812 CGP CGP CGP CGP CGP 81562-M CGP 81688-M CGP 81812-M CGP CGP CGP CGP 51000-M 51125-M 51250-M 51375-M – 11A–21 Conduit Size (Inches) – 81250 81562 81688 81812 Dimension Table (Straight Body) NUT BODY WASHER BUSHING Dimensions (Inches) Conduit Size A B C D E F /2 0.58 0.53 0.72 1.81 1.09 1.33 1 A E F B C 3 /4 0.81 0.56 0.86 2.06 1.38 1.52 1 1.00 0.62 0.97 2.31 1.56 1.70 11/4 1.31 0.69 1.25 2.78 2.16 2.50 11/2 1.50 0.69 1.25 2.78 2.16 2.50 2 1.84 0.84 1.72 3.75 2.83 3.25 D *Not UL listed 333 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 334 Cord Grip Fittings (90 Degree Body) Note: Consult factory for alternate materials (i.e., stainless steel) Features/Benefits: • Aluminum body and nut for exceptional corrosion resistance • Tapered rubber bushing (grommet) provides raintight, dust-tight seal and provides resistance to cutting oils, age hardening, compression set and normal temperature extremes • Anti-friction washer is supplied between the nut and bushing for ease in compression • Machine cut threads prevent cross threading, ensure smooth compression and watertight make-up in conduit hubs • Mesh option available in most sizes for additional support Applications: For terminating cable in conduit hubs or knock-outs and for providing relief from strain on cable Certifications: CGP (90 Degree Body) Conduit Size (Inches) Cable Range (Inches) /2 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 .125-.188 .188-.250 .250-.312 .312-.375 .375-.438 .438-.500 .500-.562 .562-.625 CGP CGP CGP CGP CGP CGP CGP CGP 92188* 92250 92312 92375 92438 92500 92562 92625 CGP CGP CGP CGP CGP CGP CGP 92250-M 92312-M 92375-M 92438-M 92500-M 92562-M 92625-M /4 /4 3 /4 3 /4 3 /4 .438-.562 .500-.625 .562-.688 .625-.750 .688-.812 CGP CGP CGP CGP CGP 93562 93625 93688 93725 93812 CGP CGP CGP CGP CGP 93562-M 93625-M 93688-M 93725-M 93812-M 1 1 3 3 11A–22 1 1 1 1 1 1 1 Catalog Number Cord Grip Only .438-.562 .500-.625 .562-.688 .625-.750 .688-.812 .750-.875 .812-.938 CGP CGP CGP CGP CGP CGP CGP 94562 94625 94688 94750 94812 94875 94938 Catalog Number Cord Grip with Mesh Conduit Size (Inches) – 11/4 11/4 11/4 11/4 11/4 .750-.875 .875-1.000 1.000-1.125 1.125-1.250 1.250-1.375 CGP CGP CGP CGP CGP 11/2 11/2 11/2 11/2 11/2 11/2 .750-.875 .875-1.000 1.000-1.125 1.125-1.250 1.250-1.375 1.312-1.438 CGP 96875 CGP 961000 CGP 961125 CGP 961250 CGP 961375 CGP961438 CGP 961000-M CGP 961125-M CGP 961250-M CGP 961375-M CGP961438-M 2 2 2 2 1.250-1.375 1.438-1.562 1.562-1.688 1.688-1.812 CGP CGP CGP CGP CGP 981562-M CGP 981688-M CGP 981812-M CGP CGP CGP CGP CGP CGP CGP 94562-M 94625-M 94688-M 94750-M 94812-M 94875-M 94938-M Cable Range (Inches) Catalog Number Cord Grip Only Catalog Number Cord Grip with Mesh – 95875 951000 951125 951250 951375 CGP CGP CGP CGP 951000-M 951125-M 951250-M 951375-M – – 981250 981562 981688 981812 Dimension Table (90 Degree Body) Dimensions (Inches) A Conduit Size A B C D E F G /2 0.58 0.56 1.88 2.39 1.03 1.33 1.50 3 /4 0.76 0.63 2.25 2.88 1.25 1.52 1.94 1 1 0.99 0.63 2.41 3.13 1.44 1.70 2.00 11/4 1.28 0.69 3.19 4.41 2.13 2.55 2.69 11/2 1.40 0.69 3.19 4.41 2.13 2.55 2.69 2 1.90 0.81 4.03 5.56 2.81 3.25 3.19 E D C B G F *Not UL listed 334 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 335 Cable Grip Fittings Features/Benefits: • Neoprene bushing provides raintight seal • Smooth bored for passage of the cable straight into the metal clad equipment or through a bulkhead Note: Provides cable support for multiple conductor and/or large single conductor cables entering metal cabinets or passage through metal plates, switchgear, etc. Application: For terminating cable in all locations To Order: Select fitting based on diameter of cable Catalog Number Dimensions (Inches) C Conduit Size D Fitting O.D. E Overall Length G Ship Wt. (Lbs.) CG 138-15 CG 155-15 1.28 1.38 1.38 1.55 1 1/2 1 1/2 2 7/8 2 7/8 3 1/4 3 1/4 2 1/2 2 1/2 1 1 CG 174-20 CG 188-20 CG 195-20 1.54 1.66 1.73 1.74 1.88 1.95 2 2 2 3 1/4 3 1/4 3 1/4 4 4 4 3 3 3 1 1/4 1 1/4 1 1/4 CG 219-25 CG 236-25 1.95 2.16 2.19 2.36 2 1/2 2 1/2 4 4 4 1/2 4 1/2 3 3/8 3 3/8 2 2 CG 263-30 CG 280-30 CG 296-30 2.35 2.61 2.74 2.63 2.80 2.96 3 3 3 4 13/16 4 13/16 4 13/16 4 7/8 4 7/8 4 7/8 3 3/4 3 3/4 3 3/4 3 3 3 CG CG CG CG 297-35 311-35 327-35 343-35 2.74 2.94 3.09 3.20 2.97 3.11 3.27 3.43 3 3 3 3 5 5 5 5 5 5 5 5 4 4 4 4 3 3 3 3 CG 364-40 CG 369-40 CG 387-40 3.31 3.52 3.64 3.64 3.69 3.87 4 4 4 /2 /2 1 /2 1 /2 1 1 /16 /16 3 /16 3 /16 3 3 5 13/16 5 3/16 5 3/16 /4 /4 1 /4 1 /4 1 1 5 3/8 5 3/8 5 3/8 /8 /8 1 /8 1 /8 1 1 4 3/16 4 3/16 4 3/16 /4 /4 3 /4 3 /4 3 3 4 1/4 4 1/4 4 1/4 11A–23 A Dia. Over Jacket Min. Max. E G D A C = THREAD 335 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 336 Boots – Protective Covering For AC Type Fittings Because of superior holding strength, AC fittings are sometimes used with jacketed cables in wet or contaminated areas. For these applications, boots are available. End fitting clamping is made on the bare armor and the boot protects the fitting and exposed cable armor. Boots are used on cable splice entrance fittings and AC or ACS type terminations. Application: Protects AC fittings in wet or contaminated areas To Install: Measure O.D. over jacket. Turn boot inside out and cut to diameter 1/4” less than measured O.D. Leaving boot inside out, push back over cable. Install fitting with jacket removed as shown. Tighten clamp. Pull boot into place snapping rim around flange of fitting. Tighten locknut and, if desired, apply wrap of PVC tape around junction of jacket and boot. To Order: Select boot based on selected AC fitting (see page 11A–19 for AC fittings) Note: 50 piece minimum Dimensions (Inches) Catalog Number BT3 BT15 BT20 BT25 BT30 BT35 BT40 BT50 For Use With Fitting Catalog Number AC AC AC AC AC AC AC AC 6-8 10-14 16-18 20-22 24-28 30-34 36 38-48 A 5 5 6 7 7 7 8 8 B /2 /4 1 /2 /16 /16 1 5/16 1 7/8 2 2 5/8 3 3/16 3 3/8 1 11 1 1 /2 1 /2 13 C 1 1 2 2 3 4 4 5 D /8 /8 3 /8 7 /8 1 /2 2 2 3 3 4 4 5 6 1 5 1 9 /2 /16 /2 /2 1 /4 5 /8 1 /4 1 /2 1 /4 5 /8 1 1 Ship Wt. (Ozs.) 5 5 7 8 10 12 13 15 11A–24 B PVC TAPE A D C BT neoprene boot installed on Type AC fitting to provide moisture and corrosion protection 336 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 337 Flange Supports for Cable Connector Fittings Features/Benefits: • Flanges complete with hardware and gaskets • Copper free aluminum alloy for excellent corrosion resistance • Provides threaded hub for terminators FS Cat. No. Application: For added support on switchgear or entrances to metallic enclosures Notes: • For use with JAG, AC(S) and CG • For blind tap, use suffix L FS5 Cat. No. Conduit Size (Inches) Ship Wt. (Lbs.) FS20 – 2 2 3/4 FS25 FS525 2 1/2 2 3/4 FS30 FS530 3 2 3/4 FS35 FS535 3 1/2 2 3/4 FS40 FS540 4 2 3/4 FS50 – 5 2 3/4 *FS60L – 6 2 3/4 11A–25 *Available in blind tap only FS5 for JAG, AC(S) and CG FS for JAG, AC(S) and CG CONDUIT SIZE CONDUIT SIZE 1 7 /4 DIA. 73/8 SQ. 31/4 7/16 31/4 3 1/16 7/16 7/16” DIA. 8 HOLES 9 /16” DIA. 6 HOLES TYPE FS STYLE TYPE FS5 STYLE 337 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 338 Brackets Features/Benefits: • Aluminum alloy for excellent corrosion resistance • Provide rigid support and effectively prevent movement of cables at termination point B Applications: For mounting of connectors and terminators on walls, ceilings or structures. A Type BAC Brackets provide convenient means for installing and terminating armored cable inside switchgear and control compartments. They may also be used to terminate cable parallel to wall, ceiling, or other surfaces, when desired. E F D1 H Certification: D2 Note: For use with all Adalet Fittings C To Order: Order BAC based on conduit size of the fittings to be used Dimensions (Inches) 11A–26 A Conduit Size B Catalog Number C BAC12 BAC15 BAC20 BAC25 1 1/4 1 1/2 2 2 1/2 4 4 4 1/8 5 3 3 4 4 1 BAC30 BAC35 BAC40 BAC50 BAC60 3 3 1/2 4 5 6 5 6 6 7 9 5 5 6 7 9 1 1 D E D2 F H Ship Wt. (Lbs.) /8 /8 1 /2 9 /16 1 /4 5 1 /2 /2 1 /8 1 /2 2 2 3 3 3 /8 /8 1 /2 1 /2 1 /8 4 4 4 5 7 3 1 5 /4 /4 5 /16 3 /4 2 2 3 3 3 /8 /8 5 /8 1 /2 1 /8 4 4 5 6 8 3 3 7 /4 /4 5 /16 3 /4 2 3/4 2 3/4 3 3 1/4 /16 /16 1 1/2 1 1/2 /8 /8 5 /8 5 /8 1 /4 3 3 4 4 6 1 2 3 3 4 3 7 /16 /16 1 /2 3 /4 9 13 17 17 3 /4 /32 /32 9 /32 9 /32 2 2 2 2 1/2 /32 /32 11 /32 11 /32 11 /32 3 3 1/2 3 1/2 4 6 9 9 9 11 /8 /8 1 /2 1 3 338 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 339 Flanged Angle Adapter for Metal Clad Terminators Features/Benefits: • Terminate armor at a 45˚ angle and permit bending single conductors in a reduced space • Adapters are supplied complete with gaskets and fasteners • Aluminum alloy for excellent corrosion resistance Application: For angle mounting of connectors and terminators to boxes and equipment Certification: Note: Type TFA Terminating Fitting Adapters are designed for use with Type AC, ACS, or JAG fittings in conduit sizes from 2 1/2” to 6” To Order: Base selection on fitting conduit size from Column C of fitting catalog page Dimensions (Inches) Catalog Number A Length B Width C Height 2 1/2 3 3 1/2 4 5 6 8 3/4 10 10 1/2 11 1/4 13 5/16 15 7/16 6 1/2 6 3/4 7 5/8 8 1/8 9 3/4 11 1/8 3 4 4 4 5 6 /16 /4 3 /8 3 /4 7 /8 3 /4 9 1 D 2 2 3 3 2 3 E /16 /16 3 /8 5 /8 5 /16 3 /8 3 3 3 3 3 3 13 15 Ship Wt. (Lbs.) /16 3 3 1/2 3 3/4 4 5 1/2 9 15 /16 /16 1 /16 5 /8 3 7 11A–27 TFA45-25 TFA45-30 TFA45-35 TFA45-40 TFA45-50 TFA45-60 For Fittings Having Conduit Size D D D D D D E 3 /8 -16 x 1 1/4 HEX BOLT D E E 3 /8 -16 x 1 1/4 HEX BOLT E 3 /8 -16 x 1 1/4 HEX BOLT E TFA45-25 E E E E TFA45-30 TFA45-35 TFA45-40 TFA45-50 TFA45-60 339 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 340 Conduit Ventilating Cable Supports Features/Benefits: • Helps reduce temperatures in conduit, improving service life and load carrying capacity of the cable • Neoprene packing gland provides watertight seal and cable support • Set screws secure the ventilator to conduit Note: Type CV Supports are designed for use at top of conduit where cable extends into air To 1. 2. 3. Application: For supporting and sealing cable risers and allowing escape of heated air from conduit Order: Select catalog number of fitting Indicate number and diameter of cables Where used with interlocked armored cable, specify whether gasket to fit over jacket or over armor Dimensions (Inches) Catalog Number A* Conduit Size B Max. Cable O.D. 1-3/C 3-1/C** C D Ship Wt. (Lbs.) CV20 CV25 CV30 2 2 1/2 3 1.60 1.91 2.37 .74 .93 1.19 4 11/16 5 5/32 5 13/16 2 5/8 2 5/8 2 3/4 2 1/2 2 1/2 3 CV35 CV40 CV50 CV60 3 1/2 4 5 6 2.75 3.12 3.82 4.42 1.41 1.63 2.13 2.55 6 6 8 9 2 2 3 3 3 1/2 4 5 6 /16 /16 1 /8 5 /8 3 13 /4 /8 3 /8 3 /4 3 7 * Metallic conduit - fitting can be adapted for other materials ** Additional holes can be supplied - consult factory 11A–28 C ILLUSTRATING MULTI-CONDUCTOR ENTRANCE D IR A IR A A 340 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 341 Bottom Conduit Ventilators Features/Benefits: • Castings are aluminum, anodized and Teflon sealed for maximum corrosion resistance • Helps reduce temperature in conduit riser, improving service life and load carrying capacity of the cable Application: Used in conduit system to allow air to enter conduit riser Dimensions (Inches) A Conduit Size* Catalog Number BCV BCV BCV BCV BCV BCV BCV 20 25 30 35 40 50 60 C D Ship Wt. (Lbs.) 2 2 1/2 3 3 1/2 4 5 6 3 5 5 6 6 8 9 /8 /8 9 /16 1 /8 1 /2 1 /4 5 /16 5 1 2 4 4 4 4 4 5 7 /8 2 3 3 1/2 4 4 6 8 /4 /2 1 /2 7 /8 1 /4 1 1 11A–29 * Metallic conduit. Fitting can be adapted for other types. R D AIR AI AIR AIR A C 341 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:28 AM Page 342 Split Conduit Ventilating Cable Supports Feature/Benefit: • Split to permit insulation after cable has been pulled or where cable extends some distance from ventilator mounting Application: Used where existing XLP or EPR cables are installed in conduit Note: For installation after pulling cable To Order: 1. Select catalog number of fitting 2. Indicate number and diameter of cables 3. Where used with interlocked armored cable, specify whether gasket to fit over jacket or over armor Dimensions (Inches) Catalog Number CVS CVS CVS CVS CVS CVS CVS 20 25 30 35 40 50 60 A Conduit Size* 2 2 1/2 3 3 1/2 4 5 6 B Max. Cable O.D. C 1-3/C 3-1/C** 1.50 1.80 2.23 2.60 2.92 3.68 4.42 .54 .75 1.00 1.25 1.44 1.87 2.18 D Ship Wt. (Lbs.) 4 5 5 6 6 7 9 /8 /4 3 /4 1 /8 3 /4 3 /4 2 2 2 2 2 2 2 5 1 /8 /8 3 /8 5 /8 5 /8 3 /4 3 /4 2 2 3 3 1/2 4 5 6 3 3 * Metallic conduit - fitting can be adapted for other materials ** Additional hole can be supplied - consult factory 11A–30 C B D A 342 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 343 Splicing Kits For Use on Solid Dielectric Cable 600 V to 35 kV 100% Kits include all tapes, braids, abrasive cloth, instructions (connectors not included) for one straight splice of 1/C or 3/C cable. Notes • Catalog system provides five kits to cover most sizes from #8 AWG through 1000 MCM. Suffix provides voltage information. • For aluminum conductors or other than straight two way splices, see other options available. • Splice kits are designed for cables having standard insulation thickness and concentric strand conductors. Consult factory if insulation or stranding differs. • Reference on connectors indicate splice design. Connectors also available. • Kits suitable for tapered high voltage compression or solder connectors to standard TD-160 (not furnished). To Order Select catalog number not to exceed maximum conductor size shown. Add voltage suffix. Examples • 3/C 1/0 AWG copper 5 kV unshielded XLP – CATALOG #3SB-5 1/C 350 MCM copper cable. 175 XLP insulation 15kV 100% – CATALOG #SC-15. • 3/C 4/0 Aluminum 15kV 133%, T splice – CATALOG #3SB-16AT 1/C 600 MCM Aluminum cable. EPR insulation, 3-way-Y-35kV 100% – CATALOG #SD35AY. Catalog Number 1/C 3/C Maximum Conductor Size SA SB SC SD SE # 1AWG 250 MCM 500 MCM 750 MCM 1000 MCM 3SA 3SB 3SC 3SD 3SE PVC TAPE 3/C TAPERED COMPRESSION CONNECTOR SHOWN IN DRAWING CABLE INSULATION SPLICING TAPE Voltage Suffix for Catalog Number SEMI-CON TAPE Shielded & Unshielded 5 Unshielded 8 15 16 25 35 Shielded Shielded Shielded Shielded Shielded SHIELDING BRAID Voltage (kV) 11A–31 Catalog Suffix No. 600V – 5kV 100% 5 kV – 8kV 100% 8 kV 133% – 15 kV 100% 15 kV 133% 16 kV – 25 kV 100% 26 kV – 35 kV 100% CABLE SEMI-CON SOLDER BLOCK CABLE SHIELD GROUNDING BRAID CABLE JACKET Other Types Available Suffix Application A AT AY T Aluminum Conductor–2 way tapered connector Aluminum Conductor–3 way-T-tapered connector Aluminum Conductor–3 way-Y-tapered connector Copper–3 way-T-solder connector to TD-160 TC YC X Y Copper–3 Copper–3 Copper–4 Copper–3 way-T-tapered compression connector way-Y-tapered compression connector way-solder full duplex TD-160 way-solder half duplex to TD-160 343 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 344 Splicing Kits For Splicing PILC Complete materials, instructions, and detailed drawings for making a correctly designed straight splice in varnished cambric or paper-insulated cable are provided. (Connectors available separately.) Notes • Splice kits are designed for cables with standard cable insulations and concentric strand. Consult factory for kits varying from standard construction. • Kits are designed to be used with tapered compression or solder connectors (not furnished). See page 11A–15 to order. • For larger sizes, higher voltage, X or Y splices, or non-standard dimensions, consult factory. To Order Select catalog number for conductor size and voltage. Provide full cable description and dimensions with order. Example 3/C 350 MCM Copper PILC 15 kV 133% insulation Catalog Number: 3LPC 16 Catalog Number 1/C 3/C LPA LPB LPC LPD LPE Maximum Conductor Size 3LPA 3LPB 3LPC 3LPD 3LPE 250 500 750 1000 LEAD WIPE #1 MCM MCM MCM MCM CABLE INSULATION FILLING COMPOUND BINDING TAPE E LEAD SLEEVE SPLICING TAPE Voltage Suffix for Catalog Number Catalog Suffix No. SHIPPING TAPE Shielded & Unshielded 5 8 15 16 25 35 Voltage (kV) Unshielded 600V – 5kV 100% Shielded Shielded Shielded Shielded Shielded 5 kV – 8kV 100% 8 kV 133% – 15 kV 100% 15 kV 133% 16 kV – 25 kV 100% 26 kV – 35 kV 100% CABLE SHIELD LEAD JACKET D 11A–32 Other Suffixes Also Available Suffix X Y Application Copper – 4-way solder full duplex to TD160 Copper – 3-way solder half duplex to TD160 Three Conductor (Copper) Dimensional Data One Conductor (Copper) Dimensional Data Dimensions (Inches) Catalog No. LPA LPB LPC LPD LPE 5kV - 8kV D E 1 1/2 2 2 1/2 2 1/2 3 13 13 1/2 14 14 1/2 15 1/2 Shielded 15kV - 100% D E 2 2 2 1/2 3 3 15 1/2 16 16 1/2 17 18 Dimensions (Inches) Shielded 15kV - 133% D E 2 2 1/2 3 3 3 1/2 Catalog No. 3 3 3 3 3 21 21 1/2 22 22 1/2 23 1/2 LPA LPB LPC LPD LPE Belted 5kV - 8kV D E 3 3 1/2 4 1/2 5 5 1/2 18 1/2 20 21 1/2 22 24 Shielded 15kV - 100% D E 3 1/2 4 1/2 5 5 1/2 6 21 22 1/2 24 24 1/2 26 Shielded 15kV - 133% D E 4 4 1/2 5 1/2 6 6 1/2 24 1/2 26 27 1/2 28 30 344 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 345 Type 3AS Splicing Kits For Splicing Metal Clad Cable 600 V to 35 kV Kits complete for three copper conductors, jacketed MC cables. Designed for tapered compression or solder connectors. Connectors not included. Aluminum conductor kits available. 3-way or 4-way kits available. Aluminum casings furnished (steel and bronze casings and bronze end castings are available). Notes • Consult factory for connectors required for 3-way or 4-way splices. • Standard design includes taping cone entrances. • Compound included. If not desired, specify “less compound” on order and jacketing tapes will be furnished at same price. Complete cable description is required with order. • Reference on connectors indicates splice design. Connectors NOT included. • Order within range of conductor sizes. 3/C #8 through 3/C #1 use 3ASA kit. • Splice kits are designed for cables having standard insulation thickness and concentric strand conductors. Consult factory if insulation or stranding differs. • Kits suitable for tapered high voltage compression or solder connectors to standard TD-160 (not furnished). To Order Select catalog number for conductor size and add voltage suffix. Examples • Typical 3/C 500MCM copper 15 kV 100% insulation – CATALOG #3ASC15 (Provide O.D. over jacket and over armor with order) • Above cable Y or 3-way splice – CATALOG #3ASC-15Y • Above cable – straight splice, armor clamps, no compound – CATALOG #3ASC-15-4 entrance both ends, less compound Copper Conductor Dimensions (Inches) Conductor Size Unshielded 2300 - 5kV D E Shielded 5kV - 8kV 100% D E Shielded 8kV - 133% - 15kV 100% D E Shielded 15kV 133% D E 3 ASA 3 ASB 3 ASC #1 250 MCM 500 MCM 3 1/2 3 1/2 4 26 26 28 3 1/2 4 5 26 29 29 3 1/2 3 1/2 5 29 32 33 3 1/2 4 5 33 33 41 4 5 5 33 41 41 3 ASD 3 ASE 750 MCM 1000 MCM 5 5 29 31 5 6 30 35 5 6 33 41 5 6 41 41 6 6 41 41 11A–33 Catalog No. Unshielded 600 - 1kV D E Voltage Suffix for Catalog Number Catalog Suffix No. 1 5 8 15 16 25 35 Shielded & Unshielded Voltage (kV) Unshielded Unshielded 600V – 1kV 100% 2300V – 5kV 100% Shielded Shielded Shielded Shielded Shielded 5 kV 133% – 8kV 100% 8 kV 133% – 15 kV 100% 15 kV 133% 16 kV 100% – 25 kV 133% 26 kV 100% – 35 kV 100% TYPICAL SPLICING KIT FOR 15kV CABLE Other Suffixes Also Available Suffix A AT Application Aluminum Conductor – 2 way tapered connector Aluminum Conductor–3 way - T-tapered connector 345 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 346 Insulating Compounds for Splices, Potheads, Encapsulating Type OI Compound A medium soft, oil-insoluble, resin-base compound for applications where migration of cable oils may be a problem. Type 3000 Oil Type 3000 Oil is used for filling cable accessories where ambient temperatures do not fall below 32˚F. It is also used to exclude air between layers of varnished cambric or paper tapes. Physical and Electrical Properties Property Unit OI 3000 ˚F ˚F ˚F ˚F ˚F – 490 545 133 356 .0006 1.13 350 395 – 266 – .88 Volts Per Mil 830 586 444 – – – – 350 Power Factor .050 gap at 60 cycle 185˚F 212˚F % – 13.0 – – .1 Normal State – Med. Soft – Container Size Net Wt. (Lbs.) Flash Point Fire Point Softening Point Pouring Temp (max.) Coefficient of Expansion Specific Gravity at 77˚F Dielectric Strength .050” gap 86˚F .050” gap 140˚F .050” gap 194˚F .1” gap 77˚F Compound 11A–34 OI OI OI OI Catalog No. Compound Compound Compound Compound 3000 3000 3000 3000 3000 Flushing Flushing Flushing Flushing Flushing OI-32 OI-128 OI-256 OI-640 Oil Oil Oil Oil Oil 3000-8 3000-16 3000-32 3000-128 3000-640 1 1 2 5 quart gallon gallons gallons 2 8 16 40 1 3 /2 pint 1 1 1 5 pint quart gallon gallons /4 1 1/2 2 1/4 8 40 Thermometer for Compound Temperature Control Thermometer has 1 1/2” diameter dial, with 50˚F to 500˚F temperature range, 8” stainless steel stem and adjustable clip for supporting thermometer. Used for determining proper pouring temperature of filling compounds and flushing oils. Catalog No. GT-100F5-50-8 346 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 347 Cable Stripping Tools – Square Cut End of Cable Insulation Tool and Bushing Selection Conductor Size Bushing Range Over Insulation Dia. Min. Max. Tool Catalog Number #6-3/0 4/0-500 550-1000 1 SQ 2 SQ 3 SQ .375 .766 1.109 1.125 1.469 1.812 Extra Bushing Catalog Number Replacement Blades Catalog Number 1-S 2-S 3-S B-1 B-1 B-1 Note The Type SQ tool is designed to remove insulations such as PVC, cross-lined polyethylene, EPR or high molecular polyethylene on round conductors. It is NOT recommended for use on rubber, butyl, VC or paper insulations. INSULATION Bushing Size for SQ and PT Tools .625 .640 .656 .671 .875 .890 .906 .921 1.125 1.140 1.156 1.171 1.375 1.390 1.406 1.421 1.625 1.640 1.656 1.671 .437 .453 .468 .484 .687 .703 .718 .734 .937 .953 .968 .984 1.187 1.203 1.218 1.234 1.437 1.453 1.468 1.484 1.687 1.703 1.718 1.734 .500 .515 .531 .546 .750 .765 .781 .796 1.000 1.015 1.031 1.046 1.250 1.265 1.281 1.296 1.500 1.515 1.531 1.546 1.750 1.781 1.796 1.812 .562 .578 .593 .609 .812 .828 .843 .859 1.062 1.078 1.093 1.109 1.312 1.328 1.343 1.359 1.562 1.578 1.593 1.609 CONDUCTING JACKET OR SHIELD BUSHING FOR THIS DIAMETER TOOL CATALOG NUMBER FOR CONDUCTOR SIZE 11A–35 .375 .390 .406 .421 To Order 1. Select tool for conductor size. 2. Diameter over insulation – after semiconducting jacket is removed – must be provided with order. 3. Tool will include two bushings – one based on nearest O.D., the other to accommodate oversize insulation. 4. To obtain additional bushings order size 1S for tool 1SQ, 2S for tool 2SQ, or 3S for tool 3SQ plus diameter from above chart. Then make sure the bushing size fits the available range for the tool. 347 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 348 Cable Insulation Penciling Tools For preparing cable splices and terminations with savings in time and labor. PT tools are built to guide on the cable connector. Because of close tolerance they will work only on standard stranding indicated below. Tools may be used on XLP, polyethylene, or EPR insulation on voltage range 5 kV 100% through 25 kV 100%. Note For intermediate or special sizes or stranding consult factory for price and delivery. To Order 1. Select tool for conductor size. Diameter over insulation – after semiconducting jacket is removed – must be provided with order. 2. Tool will include two bushings – one based on nearest O.D., the other to accommodate oversize insulation – plus one extra blade. 3. To obtain additional bushings, order B bushing for suffix “B” tool, C bushing for suffix “C” tool, D bushing for suffix “D” tool, plus diameter from chart below. Then make sure the bushing size fits the available range for the tool. 4. For extra blades order the correct blade for tool size as noted in the chart. Tool and Bushing Selection Conductor Size Left Hand Lay Standard Strand Concentric Round Catalog No. PT 8B PT 6B PT 4B PT 2B PT 1B PT 10B PT 20B PT 30B 8- 7-Strand 6- 7-Strand 4- 7-Strand 2- 7-Strand 1- 19-Strand 1/0- 19-Strand 2/0- 19-Strand 3/0- 19-Strand PT 40C 4/0- 19-Strand Catalog No. Conductor Size Left Hand Lay Standard Strand Concentric Round PT PT PT PT PT 250C 300C 350C 400C 500C 250-37-Strand 300-37-Strand 350-37-Strand 400-37-Strand 500-37-Strand PT 600D PT 700D PT 750D PT 1000D 600-61-Strand 700-61-Strand 750-61-Strand 1000-61-Strand 11A–36 Suffix INSULATION Tool Ending Suffix Bushing Size Range for B, C, or D tools B C D Min. Max. .375 .500 .625 1.062 1.330 1.745 CONDUCTING JACKET OR SHIELD BUSHING FOR THIS DIAMETER TOOL CATALOG NUMBER FOR CONDUCTOR SIZE Replacement Parts Bushing Size B C D Blade Size .295B .295C .295D 348 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 349 Cable Accessories High Voltage Insulating Tape High voltage insulating tape used with rubber, cross-linked polyethylene, or EPR insulated cables for terminations or splices up to 69 kV. Properly applied, tape is self amalgamating, providing waterproof seal for direct burial. Tape will provide protection against corona even after repeated load cycles. Suitable for 130˚C emergency conditions. Catalog Number THVT THVT THVT THVT 3075 3010 3015 3020 Thickness Length (Ft.) .030 .030 .030 .030 30 30 30 30 Width (inches) 3 /4 Standard Packaging Qty. 10 10 10 10 1 1 1/2 2 rolls rolls rolls rolls Semi Conducting Tape .030 semi conducting EPR tape, self amalgamating. Used for shielding of high-voltage terminations and splices, filling indents on compression connectors, or as a replacement of strand shields. Catalog Number TSC-15 Thickness Length (Ft.) .030 15 Width (inches) 3 /4 Standard Packaging Qty. 10 rolls PVC All Weather Plastic Tape .085 flame-retardant, weather-resistant, cold temperature tape. Resistant to sunlight, oil, acids, alkalis, and chemicals. Suitable for low-voltage taping or outer jacketing on terminations and splices. TPVC-20 TPVC-66 Thickness Length (Ft.) .085 .085 20 66 Width (inches) 3 /4 /4 Standard Packaging Qty. 20 rolls 10 rolls 3 11A–37 Catalog Number Silicone Rubber Tape .015 rectangular, unsupported, self-adhering, track resistant silicone tape used with terminations such as the FSD in contaminated areas or salt atmospheres. Catalog Number TSIL-30 Thickness Length (Ft.) .015 30 Width (inches) 3 /4 Standard Packaging Qty. 10 rolls Neoprene Jacketing Tape .030 self-amalgamating jacket tape for protection of cable joints exposed to hydrocarbons. Also used for corrosion protection on lead sleeves or splice cases. Catalog Number TNJ-3075 TNJ-3010 TNJ-3015 TNJ-3020 Thickness Length (Ft.) .030 .030 .030 .030 30 30 30 30 Width (inches) 3 /4 Standard Packaging Qty. 10 10 10 10 1 1 1/2 2 rolls rolls rolls rolls 349 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 350 Cable Accessories Arc Proofing Tape Fire resistant tape used for arc proofing and fireproofing cables in manholes, cable trays, switchboxes and substations. Catalog Number Length (Ft.) TAP-2015 TAP-2030 20 20 Width (inches) Standard Packaging Qty. 1 1/2 3 10 rolls 5 rolls Friction Tape .015 cotton weave tape coated both sides with asphalt. Used for mechanical protection against abrasion, bare wire, and to prevent mechanical damage. Catalog Number Length (Ft.) TFT-6575 TFT-6015 TFT-6020 60 60 60 Width (inches) Standard Packaging Qty. 3 /4 10 rolls 10 rolls 10 rolls 1 1/2 2 Varnished Dacron® Glass Tape Dacron® glass tapes are composed of Dacron® yarn and glass fiber filling thread treated with an oleoresinous varnish. These tapes may be used for splicing paper or varnished cambric and lead cables or for stress cones with pothead terminations. Tapes are dry packed. .012 thickness. Catalog Number Length (Yards) TVD-1205 TVD-1275 TVD-5475 TVD-1210 TVD-4810 4 4 18 4 16 Width (inches) 1 /2 /4 3 /4 3 1 1 Standard Packaging Qty. 100 100 10 100 10 rolls rolls rolls rolls rolls 11A–38 *Oil packed .012 X 4 yd. X 1/4, 1/2, 3/4, 1” rolls available. Consult factory. Cotton Tape Cotton Tape is one of the more versatile items required in splicing. It can be used to tie cables together, protect insulation when soldering and in extra high-voltage applications, it is used to protect the entire splice and keep it oiled during other operations. Catalog Number Length (Yards) Width (inches) 9 1 TCT-2705 /2 Standard Packaging Qty. 50 rolls Cotton Yarn Cotton Yarn is utilized to fill the corners in a properly stepped paper insulated cable. These free untwisted strands of pure cotton help to smooth the contour of these steps and effectively change them to a long, smooth taper. This is necessary to provide a surface that can be easily taped with no voids in the corners. Dry packed. Catalog Number TCY-8025 Length (Feet) 80 Width (Lbs.) 1 /4 Standard Packaging Qty. 50 350 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 351 Cable Accessories Cleaning Kit for Extruded Dielectric Cables Kit including aluminum oxide abrasive cloth, clean, lint-free rags, and non-chlorinated solvent designated for use in cleaning cables. Each kit will clean three cables from #8 through 1000 MCM in voltage ranges up to 35 kV for either termination or splicing. Catalog Number PLCK-35 Standard Packaging Qty. 10 Tinned Grounding Braid Tinned copper grounding braid used for grounding terminations and splices. Catalog Number TGB-10025 TGB-20025 TGB-10050 Length (Ft.) 100 200 100 Width (inches) 1 /4 1 /4 1 /2 Standard Strand 192/#36 (13 AWG) 192/#36 (13 AWG) 240/#30 (6 AWG) Packaging Qty. 1 1 1 Tinned Shielding Braid Tinned copper 1” tubular mesh for use with stress cones, terminations and splices. Catalog Number TSB-15 TSB-100 TSB-432 Length (Ft.) Packaging 15 100 432 Box Spool Spool Standard Packaging Qty. 20 1 1 11A–39 Bar Solder Each bar is plainly marked as to its tin / lead content. 40/60 solder is recommended for sweating connectors and joints. Catalog Number SB-4060 Content (Tin/Lead) 38/62 Weight (Lbs.) 1 Standard Packaging Qty. 50 Lbs. 351 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.11A part 2 12/9/01 11:29 AM Page 352 Cable Accessories Wire Solder Wire solder is supplied 1/8” diameter, solid. Wire solder is highly desirable for use in the tacking and joining of shielding braid and ground strap. Catalog Number SW-5050 Content (Tin/Lead) Weight (Lbs.) 50/50 1 Standard Packaging Qty. 5 lbs. Stearine Soldering Flux An activated Stearic formula flux molded in easy-to-use wickless candle form. Its waxlike texture allows the protection of areas prior to soldering by rubbing on a layer which will melt and clean the surface upon heating. Used for wiping lead joints. Catalog Number Form SSF-2 Candle Weight (Oz.) 2 Standard Packaging Qty. 10 Rosin Based Soldering Flux Non-conductive, non-corrosive flux paste for soldering of connectors, ground and shielding braid. Brush Included. Catalog Number Form SSR Paste Can Weight (Oz.) 2 Standard Packaging Qty. 12 Miscellaneous Chemicals 11A–40 Catalog Number RC-1 PCL-2 PCL-32 PCL-128 SG-1 Description Container Standard Packaging Qty. A50P68 butyl base rubber cement Non-Chlorinated cleaning solvent w/cloth Non-Chlorinated cleaning solvent Non-Chlorinated cleaning solvent Silicone Grease 1-oz. tube 2-oz. jar 1-qt. can 1-gal. can 1/4-oz. tube 24 40 10 41 50 352 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.12 12/9/01 11:30 AM Page 353 Industry Standards and Definitions North American Classification System for Hazardous Locations Three popular methods of protection which exist in North America for hazardous electrical locations: Type of Protection 1. Explosionproof North American hazardous locations are categorized by three criteria: Class - nature of hazardous substance present; Division - frequency of presence; Group - specific type of hazardous material. Method of Protection Containment 2. Increased Safety Mechanical 3. Intrinsically Safe Electrical Class I Potentially explosive gas or vapor Class II Potentially explosive dust Class III Potentially explosive fiber Division 1 Potentially explosive substance present under normal operating conditions Division 2 Potentially explosive substance present under abnormal operating conditions HAZARDOUS (CLASSIFIED) LOCATIONS or Selected Gases, Vapors and Dusts Group B - Atmospheres acrolein (inhibited) (2) arsine butadiene (1) ethylene oxide (2) hydrogen manufactured gases containing more than 30% H2 (by volume) propylene oxide (2) propylnitrate Group C - Atmospheres acetaldehyde allyl alcohol n-butyraldehyde carbon monoxide crotonaldehyde cyclopropane diethyl ether diethylamine epichlorohydrinnn ethylene ethylenimine ethyl mercaptan ethyl sulfide hydrogen cyanide hydrogen sulfide morpholine 2-nitropropane tetrahydrofuran unsymmetrical dimethyl hydrazine Group D - Atmospheres acetic acid (glacial) acetone acrylonitrile ammonia (3) benzene butane 1-butanol (butyl alcohol) 2-butanol (secondary butyl alcohol) n-butyl acetate isobutyl acetate di-isobutylene ethane ethanol (ethyl alcohol) ethyl acetate ethyl acrylate (inhibited) ethylene diamine (anhydrous) ethylene dichloride ethylene glycol monomethyl ether gasoline heptanes hexanes isoprene isopropyl ether mesityl oxide methane (natural gas) methanol (methyl alcohol) 3-methyl-1 butanol (isoamyl alcohol) methyl ethyl ketone methyl isobutyl ketone 2-methyl-1-propanol (isobutyl alcohol) 2-methyl-2-propanol (tertiary butyl alcohol) petroleum naphtha (4) pyridine octanes pentanes 1-pentanol (amyl alcohol) propane 1-propanol (propyl alcohol) 2-propanol (isopropyl alcohol) propylene styrene toluene vinyl acetate vinyl chloride xylenes Group E - Atmospheres containing metal dust, including aluminum, magnesium, and their commercial alloys, and other metals of similarly hazardous characteristics Group F - Atmospheres containing carbon black, coal or coke dust Group G - Atmospheres containing flour, starch or grain dust Note: Carbon disulfide must be treated in a special manner. Example: An area where hydrogen was present under normal operating conditions would require a product suitable for Class I, Division 1, Group B applications. 353 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 12A–1 Group A - Atmospheres acetylene 15599 Sec.12 12/9/01 11:30 AM Page 354 Industry Standards and Definitions NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian Standards Association CSA Standard C22.2 No 94 12A–2 Type 1 Indoor use to provide a degree of protection against contact with the enclosed equipment; in locations where unusual service conditions do not exist Indoor use to provide a degree of protection against contact with the enclosed equipment and against a limited amount of falling dirt General purpose enclosure; protects against accidental contact with live parts Type 2 Indoor use to provide a degree of protection against contact with the enclosed equipment and against limited amounts of falling water and dirt Indoor use to provide a degree of protection against limited amounts of falling water and dirt Drip proof enclosure same as Type 1; indoor use to provide a degree of protection against dripping and light splashing of noncorrosive liquids and falling dirt Type 3 Indoor or outdoor use to provide a degree of protection against windblown dust, rain and sleet; undamaged by the formation of ice on the enclosure (not sleet proof) Indoor or outdoor use to provide a degree of protection against windblown dust, rain and sleet; undamaged by the formation of ice on the enclosure Weatherproof enclosure; indoor or outdoor use to provide a degree of protection against rain, snow and blown dust; undamaged by the external formation of ice on the enclosure Type 3R Indoor or outdoor use to provide a degree of protection against falling rain and sleet; undamaged by the formation of ice on the enclosure Indoor or outdoor use to provide a degree of protection against falling rain and sleet; undamaged by the formation of ice on the enclosure Weather proof enclosure; indoor or outdoor use to provide a degree of protection against rain or snow; undamaged by the external formation of ice on the enclosure (CSA does not specify sleet resist) Type 3S Indoor or outdoor use to provide a degree of protection against windblown dust, rain and sleet; provides for operation of external mechanisms when ice laden Indoor or outdoor use to provide a degree of protection against windblown dust, rain and sleet; external mechanisms remain operable while ice laden Weather proof enclosure; indoor or outdoor use to provide a degree of protection against rain or snow; undamaged by the external formation of ice on the enclosure surface (CSA does not specify sleet proof) Type 4 Indoor or outdoor use to protect the enclosed equipment against splashing water, seepage of water, falling or hose-directed water, and severe external condensation; these enclosures are sleet resistant but not sleet proof Indoor or outdoor use to provide a degree of protection against splashing water, windblown dust and rain, and hose directed water; undamaged by the formation of ice on the enclosure Watertight enclosure; indoor or outdoor use to provide a degree of protection against rain, snow, blown dust, splashing and hose directed water; undamaged by the external formation of ice on the enclosure Type 4X Indoor or outdoor use to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose-directed water; undamaged by the formation of ice on the enclosure Indoor or outdoor use to provide a degree of protection against splashing water, windblown dust and rain, and hose directed water; undamaged by the formation of ice on the enclosure; resists corrosion Watertight enclosure; indoor or outdoor use to provide a degree of protection against rain, snow, blown dust, splashing and hose directed water; undamaged by the external formation of ice on the enclosure; resists corrosion Not typically used by UL. Indoor use, so constructed that dust, readily ignitable fibers or combustible flyings cannot enter the enclosure Type 5 Indoor use to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids 354 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.12 12/9/01 11:30 AM Page 355 Industry Standards and Definitions NEMA Designation Underwriters Laboratories Inc. UL 50 and UL 508 Canadian Standards Association CSA Standard C22.2 No 94 Type 6 Indoor or outdoor use to provide a degree of protection against the entry of water during occasional temporary submersion at a limited depth Indoor or outdoor use to provide a degree of protection against the entry of water during temporary submersion at a limited depth; undamaged by the formation of ice on the enclosure No CSA equivalent Type 6P Indoor or outdoor use to provide a degree of protection against the entry of water during prolonged submersion at a limited depth Indoor or outdoor use to provide a degree of protection against the entry of water during prolonged submersion at a limited depth No CSA equivalent Type 7 For use in indoor locations classified as Class I, Groups A, B, C and D, as defined in the National Electrical Code Not typically used by UL Similar to NEMA designation; refer to Canadian Electric Code C22.1 Sec. 18 (C22.2 No. 30) Type 8 For use in indoor or outdoor locations classified as Class I, Groups A, B, C and D, as defined in the National Electrical Code – oil immersed Not typically used by UL Similar to NEMA designation; refer to Canadian Electric Code C22.1 Sec. 18 (C22.2 No. 30) Type 9 For use in indoor locations classified as Class II, Groups E, F and G, as defined in the National Electrical Code Not typically used by UL Similar to NEMA designation dust tight (hazardous dust); refer to Canadian Electric Code C22.2 No. 25 Type 10 Mining enforcement safety administration approved Not typically used by UL No CSA equivalent specified for industrial control applications (See C22.5 for use of electricity in mines) Type 11 Indoor use to provide, by oil immersion, a degree of protection to enclosed equipment against corrosive effects of liquids and gases Indoor use to provide, by oil immersion, a degree of protection of the enclosed equipment against corrosive effects of corrosive liquids and gases No CSA equivalent; similar to Type 4 Indoor use to provide a degree of protection against dust, falling dirt and dripping non-corrosive liquids No knockouts Indoor use to provide a degree of protection against dust, falling dirt and dripping non-corrosive liquids No knockouts Indoor use to provide a degree of protection against circulating dust, lint, fibers, dripping and light splashes of non-corrosive liquids Indoor enclosure with knockouts to provide a degree of protection against dust, falling dirt and dripping non-corrosive liquids other than at knockouts Indoor use to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids With knockouts No CSA equivalent Indoor use to provide a degree of protection against dust and spraying of water, oil and noncorrosive coolants Indoor use to provide a degree of protection against circulating dust, lint, fibers, seepage and spraying of non-corrosive liquids including oils and coolants 12A–3 Type 12 Type 12K Type 13 Indoor use to provide a degree of protection against lint, dust, seepage, external condensation and spraying of water, oil and noncorrosive coolant 355 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.12 12/9/01 11:30 AM Page 356 Industry Standards and Definitions EUROPEAN STANDARDS Type of Protection Method of Protection CENELEC Designation Flameproof Enclosure Containment ‘d’ Increased Safety Mechanical ‘e’ Intrinsically Safe Electrical ‘i’ These designations are typically preceded by EEx, the designation indicating an apparatus built to a European standard. European Classification of Hazardous Locations Zone 0 Explosive gas present continuously Zone 1 Explosive gas present occasionally under normal operating conditions Zone 2 Explosive gas present for short period Zone 20 Explosive dust present continuously Zone 21 Explosive dust present occasionally under normal operating conditions Zone 22 Explosive dust present for short period Explosion Groups Group I Electrical equipment for mining applications Group II Electrical equipment for all remaining hazardous areas Ingress Protection (IP rating) defines the degree of protection Scope of Protection for the IP protection classes First Digit Digit Second digit Water protection No protection 0 No protection Protection against back of hand contact Protection against solid foreign bodies 50 mm diameter 1 Protection against water drops falling vertically 2 Protection against finger contact Protection against solid foreign bodies 12.5 mm diameter 2 Protection against water drops falling at an angle (15°) 3 Protection against contact from tools Protection against solid foreign bodies 2.5 mm diameter 3 Protection against waterspray at an angle up to 60° 4 Protection against contact with a wire Protection against solid foreign bodies 1.0 mm diameter 4 Protection against waterspray from all directions 5 Protection against contact with a wire Protection against dust 5 Protection against water jets 6 Protection against contact with a wire Dust-tight 6 Protection against strong water jets 7 7 Protection against intermittent immersion in water 8 8 Protection against continuous immersion in water Digit Physical protection Foreign body protection 0 No protection 1 12A–4 356 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.12 12/9/01 11:30 AM Page 357 Industry Standards and Definitions CLASSIFICATION BY GROUP AND CATEGORY ACCORDING TO INTENDED USE (Surface Industry) Area Category of Equipment Presence or Duration of Explosive Atmosphere Inflammable Substances Continuous Presence 1 Long Periods Gas, Vapors, Mist, Dust Frequent Equipment Group II (surface) Level of Protection Faults to Allow for Comparison with Present Practice Very High Level of Protection Group II Zone 0 (gas) Zone 20 (dust) 2 types of protection or 2 Independent faults High Level of Protection 2 Likely to Occur Gas, Vapors, Mist, Dust 1 Type of Protection Habitual frequent malfunction Unlikely to Occur Present for a Short Period Gas, Vapors, Mist, Dust Normal Protection Required Level of Protection Group II Zone 2 (gas) Zone 22 (dust) 12A–5 3 Group II Zone 1 (gas) Zone 21 (dust) 357 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Sec.12 12/9/01 11:30 AM Page 358 Industry Standards and Definitions TEMPERATURE RATING The maximum surface temperature of the exposed surface of electrical apparatus must always be lower than the ignition temperature of the gas or vapor mixture. Temperature Class Maximum Ignition Temperature Surface Temperature of Combustible Material 450 C 300 C 200 C 135 C 100 C 85 C >450 C >300 C >200 C >135 C >100 C >85 C TI T2 T3 T4 T5 T6 Safety characteristics of flammable gases and vapors Ignition temperature °C Acetaldehyde Acetic acid Acetic anhydride Acetone Acetylene Ammonia Amylacetate Benzene Benzol Carbon disulfide Carbon monoxide Cyclohexene 1,2-Dichlorethane Diesel fuel Ethane Ethylacetate Ethylalcohol Ethylchloride Ethylene Ethylenoxide Ethylether Ethyl glycol Fuel oil Hydrogen Hydrogen disulfide Methane Methanol Methyl chloride n-Butane n-Butylalcohol n-Hexane n-Propylalcohol Naphthaline Oleic acid Phenol Propane Tetraline Toluole 140 485 330 540 305 630 380 220 555 95 605 430 440 220 up to 300 515 460 425 510 425 440 180 235 220 up to 300 560 270 595 (650) 455 625 365 340 240 405 520 360 595 470 425 535 Temperature class T4 T1 T2 T1 Explosion group II II II II A A A A II II II II A A A A II II II II II II II II A A A A A A A A T2 IIC T1 T2 T3 T1 T6 T1 T2 T2 T3 T1 T1 T2 T1 IIC T2 T2 II B II B II B T4 T3 T3 II B II A T1 IIC T3 T1 T1 T1 T2 T2 T3 II B II II II II II II A A A A A A T2 T1 II A T2 T1 T1 II A II A T2 T1 II A 358 ADALET Enclosure Systems • Designing Our Products Around Yours T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 12A5 12A–6 Medium 15599 Index 12/10/01 5:28 PM Page 359 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section .295 B BLADES . . . . . . . . . . .11A 12MF-12-SS . . . . . . . . . . . . . .1C 3 ASC-5A . . . . . . . . . . . . . . .11A 3SB-15 . . . . . . . . . . . . . . . . .11A .295 C BLADES . . . . . . . . . . .11A 12P10 . . . . . . . . . . . . . . . . . . .1C 3 ASC-5Y . . . . . . . . . . . . . . .11A 3SB-16 . . . . . . . . . . . . . . . . .11A .295 D BLADES . . . . . . . . . .11A 12P12 . . . . . . . . . . . . . . . . . . .1C 3 ASC-8 . . . . . . . . . . . . . . . .11A 3SB-25 . . . . . . . . . . . . . . . . .11A 06P04 . . . . . . . . . . . . . . . . . . .1C 14P08 . . . . . . . . . . . . . . . . . . .1C 3 ASC-8A . . . . . . . . . . . . . . .11A 3SB-35 . . . . . . . . . . . . . . . . .11A 06P06 . . . . . . . . . . . . . . . . . . .1C 14P12 . . . . . . . . . . . . . . . . . . .1C 3 ASC-8Y . . . . . . . . . . . . . . .11A 3SB-5 . . . . . . . . . . . . . . . . . .11A 07-3323-1100/1000 . . . . . . . . .3D 16P14 . . . . . . . . . . . . . . . . . . .1C 3 ASD-1 . . . . . . . . . . . . . . . .11A 3SB-8 . . . . . . . . . . . . . . . . . .11A 07-3323-1100/2000 . . . . . . . . .3D 1-S BUSHING . . . . . . . . . . . .11A 3 ASD-15 . . . . . . . . . . . . . . .11A 3SC-15 . . . . . . . . . . . . . . . . .11A 07-3323-1100/3000 . . . . . . . . .3D 1-SQ . . . . . . . . . . . . . . . . . . .11A 3 ASD-15A . . . . . . . . . . . . . .11A 3SC-16 . . . . . . . . . . . . . . . . .11A 07-3323-1100/4000 . . . . . . . . .3D 2-S BUSHING . . . . . . . . . . . .11A 3 ASD-15Y . . . . . . . . . . . . . .11A 3SC-25 . . . . . . . . . . . . . . . . .11A 07-3323-1100/4100 . . . . . . . . .3D 2-SQ . . . . . . . . . . . . . . . . . . .11A 3 ASD-16 . . . . . . . . . . . . . . .11A 3SC-35 . . . . . . . . . . . . . . . . .11A 07-3323-1100/4200 . . . . . . . . .3D 3 ASA-1 . . . . . . . . . . . . . . . .11A 3 ASD-16A . . . . . . . . . . . . . .11A 3SC-5 . . . . . . . . . . . . . . . . . .11A 07-3323-1100/4300 . . . . . . . . .3D 3 ASA-15 . . . . . . . . . . . . . . .11A 3 ASD-16Y . . . . . . . . . . . . . .11A 3SC-8 . . . . . . . . . . . . . . . . . .11A 07-3323-1100/5000 . . . . . . . . .3D 3 ASA-15A . . . . . . . . . . . . . .11A 3 ASD-1A . . . . . . . . . . . . . . .11A 3SD-15 . . . . . . . . . . . . . . . . .11A 07-3323-1100/6000 . . . . . . . . .3D 3 ASA-15Y . . . . . . . . . . . . . .11A 3 ASD-1Y . . . . . . . . . . . . . . .11A 3SD-16 . . . . . . . . . . . . . . . . .11A 07-3323-1100/6100 . . . . . . . . .3D 3 ASA-16 . . . . . . . . . . . . . . .11A 3 ASD-5 . . . . . . . . . . . . . . . .11A 3SD-25 . . . . . . . . . . . . . . . . .11A 07-3323-1100/6200 . . . . . . . . .3D 3 ASA-16A . . . . . . . . . . . . . .11A 3 ASD-5A . . . . . . . . . . . . . . .11A 3SD-35 . . . . . . . . . . . . . . . . .11A 07-3323-1100/6300 . . . . . . . . .3D 3 ASA-16Y . . . . . . . . . . . . . .11A 3 ASD-5Y . . . . . . . . . . . . . . .11A 3SD-5 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/1000 . . . . . . . . .3D 3 ASA-1A . . . . . . . . . . . . . . .11A 3 ASD-8 . . . . . . . . . . . . . . . .11A 3SD-8 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/2000 . . . . . . . . .3D 3 ASA-1Y . . . . . . . . . . . . . . .11A 3 ASD-8A . . . . . . . . . . . . . . .11A 3SE-15 . . . . . . . . . . . . . . . . .11A 07-3323-1200/3000 . . . . . . . . .3D 3 ASA-5 . . . . . . . . . . . . . . . .11A 3 ASD-8Y . . . . . . . . . . . . . . .11A 3SE-16 . . . . . . . . . . . . . . . . .11A 07-3323-1200/4000 . . . . . . . . .3D 3 ASA-5A . . . . . . . . . . . . . . .11A 3 ASE . . . . . . . . . . . . . . . . . .11A 3SE-25 . . . . . . . . . . . . . . . . .11A 07-3323-1200/4100 . . . . . . . . .3D 3 ASA-5Y . . . . . . . . . . . . . . .11A 3 LPA-15 . . . . . . . . . . . . . . . .11A 3SE-35 . . . . . . . . . . . . . . . . .11A 07-3323-1200/4200 . . . . . . . . .3D 3 ASA-8 . . . . . . . . . . . . . . . .11A 3 LPA-16 . . . . . . . . . . . . . . . .11A 3SE-5 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/4300 . . . . . . . . .3D 3 ASA-8A . . . . . . . . . . . . . . .11A 3 LPA-5 . . . . . . . . . . . . . . . . .11A 3SE-8 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/5000 . . . . . . . . .3D 3 ASA-8Y . . . . . . . . . . . . . . .11A 3 LPA-8 . . . . . . . . . . . . . . . . .11A 3-SQ . . . . . . . . . . . . . . . . . . .11A 07-3323-1200/6000 . . . . . . . . .3D 3 ASB-1 . . . . . . . . . . . . . . . .11A 3 LPB-15 . . . . . . . . . . . . . . . .11A AC-10 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/6100 . . . . . . . . .3D 3 ASB-15 . . . . . . . . . . . . . . .11A 3 LPB-16 . . . . . . . . . . . . . . . .11A AC-12 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/6200 . . . . . . . . .3D 3 ASB-15A . . . . . . . . . . . . . .11A 3 LPB-5 . . . . . . . . . . . . . . . . .11A AC-14 . . . . . . . . . . . . . . . . . .11A 07-3323-1200/6300 . . . . . . . . .3D 3 ASB-15Y . . . . . . . . . . . . . .11A 3 LPB-8 . . . . . . . . . . . . . . . . .11A AC-16 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/1000 . . . . . . . . .3D 3 ASB-16 . . . . . . . . . . . . . . .11A 3 LPC-15 . . . . . . . . . . . . . . . .11A AC-18 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/2000 . . . . . . . . .3D 3 ASB-16A . . . . . . . . . . . . . .11A 3 LPC-16 . . . . . . . . . . . . . . . .11A AC-20 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/3000 . . . . . . . . .3D 3 ASB-16Y . . . . . . . . . . . . . .11A 3 LPC-5 . . . . . . . . . . . . . . . . .11A AC-22 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/4000 . . . . . . . .3D 3 ASB-1A . . . . . . . . . . . . . . .11A 3 LPC-8 . . . . . . . . . . . . . . . . .11A AC-24 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/4100 . . . . . . . .3D 3 ASB-1Y . . . . . . . . . . . . . . .11A 3 LPD-15 . . . . . . . . . . . . . . . .11A AC-26 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/4200 . . . . . . . .3D 3 ASB-5 . . . . . . . . . . . . . . . .11A 3 LPD-16 . . . . . . . . . . . . . . . .11A AC-28 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/4300 . . . . . . . .3D 3 ASB-5A . . . . . . . . . . . . . . .11A 3 LPD-5 . . . . . . . . . . . . . . . . .11A AC-30 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/5000 . . . . . . . . .3D 3 ASB-5Y . . . . . . . . . . . . . . .11A 3 LPD-8 . . . . . . . . . . . . . . . . .11A AC-32 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/6000 . . . . . . . . .3D 3 ASB-8 . . . . . . . . . . . . . . . .11A 3 LPE . . . . . . . . . . . . . . . . . .11A AC-34 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/6100 . . . . . . . . .3D 3 ASB-8A . . . . . . . . . . . . . . .11A 3000-128 1 GA . . . . .11A AC-36 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/6200 . . . . . . . . .3D 3 ASB-8Y . . . . . . . . . . . . . . .11A 3000-16 1 PT . . . . . .11A AC-38 . . . . . . . . . . . . . . . . . .11A 07-3323-1400/6300 . . . . . . . . .3D 3 ASC-1 . . . . . . . . . . . . . . . .11A 3000-32 1 QT . . . . .11A AC-6 . . . . . . . . . . . . . . . . . . .11A 07-3353-1110/1000 . . . . . . . . .3D 3 ASC-15 . . . . . . . . . . . . . . .11A 3000-640 1-149 GAL. 5 GA .11A AC-8 . . . . . . . . . . . . . . . . . . .11A 07-3353-1120/2000 . . . . . . . . .3D 3 ASC-15A . . . . . . . . . . . . . .11A 3000-640 150 & OVER 5 GA 11A ACS-10 . . . . . . . . . . . . . . . . .11A 07-3353-1130/3000 . . . . . . . . .3D 3 ASC-15Y . . . . . . . . . . . . . .11A 3000-8 1/2 . . . . . . .11A ACS-12 . . . . . . . . . . . . . . . . .11A 07-3353-1140/4000 . . . . . . . . .3D 3 ASC-16 . . . . . . . . . . . . . . .11A 3-S BUSHING . . . . . . . . . . . .11A ACS-14 . . . . . . . . . . . . . . . . .11A 07-3353-1150/5000 . . . . . . . . .3D 3 ASC-16A . . . . . . . . . . . . . .11A 3SA-15 . . . . . . . . . . . . . . . . .11A ACS-16 . . . . . . . . . . . . . . . . .11A 08P06 . . . . . . . . . . . . . . . . . . .1C 3 ASC-16Y . . . . . . . . . . . . . .11A 3SA-16 . . . . . . . . . . . . . . . . .11A ACS-18 . . . . . . . . . . . . . . . . .11A 08P08 . . . . . . . . . . . . . . . . . . .1C 3 ASC-1A . . . . . . . . . . . . . . .11A 3SA-25 . . . . . . . . . . . . . . . . .11A ACS-20 . . . . . . . . . . . . . . . . .11A 10P08 . . . . . . . . . . . . . . . . . . .1C 3 ASC-1Y . . . . . . . . . . . . . . .11A 3SA-5 . . . . . . . . . . . . . . . . . .11A ACS-22 . . . . . . . . . . . . . . . . .11A 10P10 . . . . . . . . . . . . . . . . . . .1C 3 ASC-5 . . . . . . . . . . . . . . . .11A 3SA-8 . . . . . . . . . . . . . . . . . .11A ACS-24 . . . . . . . . . . . . . . . . .11A 359 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 360 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX ACS-26 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-302408 . . . . .1A C-BUSHING . . . . . . . . . . . . .11A CGP 4812 . . . . . . . . . . . . . . .11A ACS-28 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-302412 . . . . .1A CG 138-15 . . . . . . . . . . . . . . .11A CGP 4812-M . . . . . . . . . . . . .11A ACS-30 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-302420 . . . . .1A CG 155-15 . . . . . . . . . . . . . . .11A CGP 4875 . . . . . . . . . . . . . . .11A ACS-32 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-303008 . . . . .1A CG 174-20 . . . . . . . . . . . . . . .11A CGP 4875-M . . . . . . . . . . . . .11A ACS-34 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-303012 . . . . .1A CG 188-20 . . . . . . . . . . . . . . .11A CGP 4938 . . . . . . . . . . . . . . .11A ACS-36 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-362408 . . . . .1A CG 195-20 . . . . . . . . . . . . . . .11A CGP 4938-M . . . . . . . . . . . . .11A ACS-38 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-362412 . . . . .1A CG 219-25 . . . . . . . . . . . . . . .11A CGP 51000 . . . . . . . . . . . . . .11A ACS-40 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-363008 . . . . .1A CG 236-25 . . . . . . . . . . . . . . .11A CGP 51000-M . . . . . . . . . . . .11A ACS-42 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-363012 . . . . .1A CG 263-30 . . . . . . . . . . . . . . .11A CGP 51125 . . . . . . . . . . . . . .11A ACS-44 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-363016 . . . . .1A CG 280-30 . . . . . . . . . . . . . . .11A CGP 51125-M . . . . . . . . . . . .11A ACS-46 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-363020 . . . . .1A CG 296-30 . . . . . . . . . . . . . . .11A CGP 51250 . . . . . . . . . . . . . .11A ACS-48 . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-363608 . . . . .1A CG 297-35 . . . . . . . . . . . . . . .11A CGP 51250-M . . . . . . . . . . . .11A ACS-6 . . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-363612 . . . . .1A CG 311-35 . . . . . . . . . . . . . . .11A CGP 51375 . . . . . . . . . . . . . .11A ACS-8 . . . . . . . . . . . . . . . . . .11A AVSS(or AVSS6)-423612 . . . . .1A CG 327-35 . . . . . . . . . . . . . . .11A CGP 51375-M . . . . . . . . . . . .11A AIPBCAR . . . . . . . . . . . . . . . .7A AVSS(or AVSS6)-483612 . . . . .1A CG 343-35 . . . . . . . . . . . . . . .11A CGP 5875 . . . . . . . . . . . . . . .11A AIPBCBE . . . . . . . . . . . . . . . .7A AVSS(or AVSS6)-483616 . . . . .1A CG 364-40 . . . . . . . . . . . . . . .11A CGP 61000 . . . . . . . . . . . . . .11A AIPBCCR . . . . . . . . . . . . . . . .7A AVSS(or AVSS6)-603612 . . . . .1A CG 369-40 . . . . . . . . . . . . . . .11A CGP 61000-M . . . . . . . . . . . .11A AIPBCGN . . . . . . . . . . . . . . . .7A B-1 BLADE . . . . . . . . . . . . . .11A CG 387-40 . . . . . . . . . . . . . . .11A CGP 61125 . . . . . . . . . . . . . .11A AIPBCRD . . . . . . . . . . . . . . . .7A BAC 12 . . . . . . . . . . . . . . . . .11A CGP 2188 . . . . . . . . . . . . . . .11A CGP 61125-M . . . . . . . . . . . .11A AIPBCWE . . . . . . . . . . . . . . . .7A BAC 15 . . . . . . . . . . . . . . . . .11A CGP 2250 . . . . . . . . . . . . . . .11A CGP 61250 . . . . . . . . . . . . . .11A APLLAR . . . . . . . . . . . . . . . . .7A BAC 20 . . . . . . . . . . . . . . . . .11A CGP 2250-M . . . . . . . . . . . . .11A CGP 61250-M . . . . . . . . . . . .11A APLLBE . . . . . . . . . . . . . . . . .7A BAC 25 . . . . . . . . . . . . . . . . .11A CGP 2312 . . . . . . . . . . . . . . .11A CGP 61375 . . . . . . . . . . . . . .11A APLLCR . . . . . . . . . . . . . . . . .7A BAC 30 . . . . . . . . . . . . . . . . .11A CGP 2312-M . . . . . . . . . . . . .11A CGP 61375-M . . . . . . . . . . . .11A APLLGN . . . . . . . . . . . . . . . . .7A BAC 35 . . . . . . . . . . . . . . . . .11A CGP 2375 . . . . . . . . . . . . . . .11A CGP 6875 . . . . . . . . . . . . . . .11A APLLRD . . . . . . . . . . . . . . . . .7A BAC 40 . . . . . . . . . . . . . . . . .11A CGP 2375-M . . . . . . . . . . . . .11A CGP 81250 . . . . . . . . . . . . . .11A APLLWE . . . . . . . . . . . . . . . . .7A BAC 50 . . . . . . . . . . . . . . . . .11A CGP 2438 . . . . . . . . . . . . . . .11A CGP 81562 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-121206 . . . . .1A BAC 60 . . . . . . . . . . . . . . . . .11A CGP 2438-M . . . . . . . . . . . . .11A CGP 81562-M . . . . . . . . . . . .11A AVSS(or AVSS6)-161206 . . . . .1A B-BUSHING . . . . . . . . . . . . .11A CGP 2500 . . . . . . . . . . . . . . .11A CGP 81688 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-161208 . . . . .1A BCV 20 . . . . . . . . . . . . . . . . .11A CGP 2500-M . . . . . . . . . . . . .11A CGP 81688-M . . . . . . . . . . . .11A AVSS(or AVSS6)-161606 . . . . .1A BCV 25 . . . . . . . . . . . . . . . . .11A CGP 2562 . . . . . . . . . . . . . . .11A CGP 81812 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-161608 . . . . .1A BCV 30 . . . . . . . . . . . . . . . . .11A CGP 2562-M . . . . . . . . . . . . .11A CGP 81812-M . . . . . . . . . . . .11A AVSS(or AVSS6)-162008 . . . . .1A BCV 35 . . . . . . . . . . . . . . . . .11A CGP 2625 . . . . . . . . . . . . . . .11A CGP 92188 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-201606 . . . . .1A BCV 40 . . . . . . . . . . . . . . . . .11A CGP 2625-M . . . . . . . . . . . . .11A CGP 92250 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-201608 . . . . .1A BCV 50 . . . . . . . . . . . . . . . . .11A CGP 3562 . . . . . . . . . . . . . . .11A CGP 92250-M . . . . . . . . . . . .11A AVSS(or AVSS6)-202006 . . . . .1A BCV 60 . . . . . . . . . . . . . . . . .11A CGP 3562-M . . . . . . . . . . . . .11A CGP 92312 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-202008 . . . . .1A BT-15 . . . . . . . . . . . . . . . . . .11A CGP 3625 . . . . . . . . . . . . . . .11A CGP 92312-M . . . . . . . . . . . .11A AVSS(or AVSS6)-202012 . . . . .1A BT1A . . . . . . . . . . . . . . . . . . .9A CGP 3625-M . . . . . . . . . . . . .11A CGP 92375 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-202408 . . . . .1A BT1B . . . . . . . . . . . . . . . . . . .9A CGP 3688 . . . . . . . . . . . . . . .11A CGP 92375-M . . . . . . . . . . . .11A AVSS(or AVSS6)-241606 . . . . .1A BT2 . . . . . . . . . . . . . . . . . . . . .9A CGP 3688-M . . . . . . . . . . . . .11A CGP 92438 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-241608 . . . . .1A BT-20 . . . . . . . . . . . . . . . . . .11A CGP 3725 . . . . . . . . . . . . . . .11A CGP 92438-M . . . . . . . . . . . .11A AVSS(or AVSS6)-242006 . . . . .1A BT-25 . . . . . . . . . . . . . . . . . .11A CGP 3725-M . . . . . . . . . . . . .11A CGP 92500 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-242008 . . . . .1A BT3 . . . . . . . . . . . . . . . . . . . . .9A CGP 3812 . . . . . . . . . . . . . . .11A CGP 92500-M . . . . . . . . . . . .11A AVSS(or AVSS6)-242012 . . . . .1A BT-3 . . . . . . . . . . . . . . . . . . .11A CGP 4562 . . . . . . . . . . . . . . .11A CGP 92562 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-242406 . . . . .1A BT-30 . . . . . . . . . . . . . . . . . .11A CGP 4562-M . . . . . . . . . . . . .11A CGP 92562-M . . . . . . . . . . . .11A AVSS(or AVSS6)-242408 . . . . .1A BT-35 . . . . . . . . . . . . . . . . . .11A CGP 4625 . . . . . . . . . . . . . . .11A CGP 92625 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-242412 . . . . .1A BT4 . . . . . . . . . . . . . . . . . . . . .9A CGP 4625-M . . . . . . . . . . . . .11A CGP 92625-M . . . . . . . . . . . .11A AVSS(or AVSS6)-242416 . . . . .1A BT-40 . . . . . . . . . . . . . . . . . .11A CGP 4688 . . . . . . . . . . . . . . .11A CGP 93562 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-242420 . . . . .1A BT44 . . . . . . . . . . . . . . . . . . . .9A CGP 4688-M . . . . . . . . . . . . .11A CGP 93562-M . . . . . . . . . . . .11A AVSS(or AVSS6)-243008 . . . . .1A BT5 . . . . . . . . . . . . . . . . . . . . .9A CGP 4750 . . . . . . . . . . . . . . .11A CGP 93625 . . . . . . . . . . . . . .11A AVSS(or AVSS6)-302008 . . . . .1A BT-50 . . . . . . . . . . . . . . . . . .11A CGP 4750-M . . . . . . . . . . . . .11A CGP 93625-M . . . . . . . . . . . .11A 360 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 361 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section CGP 93688 . . . . . . . . . . . . . .11A CN4(X or X6)-2016xx . . . . . . . .3D CVS-60 1-3/C . . . . . . . . . . . . .11A FSP 2 . . . . . . . . . . . . . . . . . . .5E CGP 93688-M . . . . . . . . . . . .11A CN4(X or X6)-2020xx . . . . . . . .3D CVS-60 3-1/C . . . . . . . . . . . . .11A FSP 3 . . . . . . . . . . . . . . . . . . .5E CGP 93725 . . . . . . . . . . . . . .11A CN4(X or X6)-2024xx . . . . . . . .3D D-60P48 . . . . . . . . . . . . . . . . .1A FVLU . . . . . . . . . . . . . . . . . . .7A CGP 93725-M . . . . . . . . . . . .11A CN4(X or X6)-2412xx . . . . . . . .3D D-60P60 . . . . . . . . . . . . . . . . .1A FVLU12 . . . . . . . . . . . . . . . . . .7A CGP 93812 . . . . . . . . . . . . . .11A CN4(X or X6)-2416xx . . . . . . . .3D D-72P60 . . . . . . . . . . . . . . . . .1A FVLU120 . . . . . . . . . . . . . . . . .7A CGP 93812-M . . . . . . . . . . . .11A CN4(X or X6)-2420xx . . . . . . . .3D D-72P72 . . . . . . . . . . . . . . . . .1A FVLU120FS . . . . . . . . . . . . . . .7A CGP 94562 . . . . . . . . . . . . . .11A CN4(X or X6)-2424xx . . . . . . . .3D D-BUSHING . . . . . . . . . . . . .11A FVLU120N . . . . . . . . . . . . . . .7A CGP 94562-M . . . . . . . . . . . .11A CN4(X or X6)-2430xx . . . . . . . .3D DIF 101406 . . . . . . . . . . . . . . .5B FVLU120NFS . . . . . . . . . . . . .7A CGP 94625 . . . . . . . . . . . . . .11A CN4(X or X6)-301606 . . . . . . .3D DIF 164810 . . . . . . . . . . . . . . .5B FVLU12FS . . . . . . . . . . . . . . . .7A CGP 94625-M . . . . . . . . . . . .11A CN4(X or X6)-3020xx . . . . . . . .3D DIF 202408 . . . . . . . . . . . . . . .5B FVLU24 . . . . . . . . . . . . . . . . . .7A CGP 94688 . . . . . . . . . . . . . .11A CN4(X or X6)-3024xx . . . . . . . .3D DIF 243608 . . . . . . . . . . . . . . .5B FVLU24FS . . . . . . . . . . . . . . . .7A CGP 94688-M . . . . . . . . . . . .11A CN4(X or X6)-3030xx . . . . . . . .3D DIF 364808 . . . . . . . . . . . . . . .5B FVLU6 . . . . . . . . . . . . . . . . . . .7A CGP 94750 . . . . . . . . . . . . . .11A CN4(X or X6)-303608 . . . . . . .3D DJF 061105 . . . . . . . . . . . . . .5A FVLU6FS . . . . . . . . . . . . . . . .7A CGP 94750-M . . . . . . . . . . . .11A CN4(X or X6)-3624xx . . . . . . . .3D DJF 061305 . . . . . . . . . . . . . .5A FVLUFS . . . . . . . . . . . . . . . . .7A CGP 94812 . . . . . . . . . . . . . .11A CN4(X or X6)-3630xx . . . . . . . .3D DJF 071805 . . . . . . . . . . . . . .5A FVPPM120-IMCRD-FS . . . . . .7A CGP 94812-M . . . . . . . . . . . .11A CN4(X or X6)-3636xx . . . . . . . .3D DJF 121806 . . . . . . . . . . . . . .5A FVPPM120-IMCRD-FS/FS . . . .7A CGP 94875 . . . . . . . . . . . . . .11A CN4(X or X6)-422408 . . . . . . .3D DJF 122005 . . . . . . . . . . . . . .5A FVPPM120NR-IMCRD-FS . . . .7A CGP 94875-M . . . . . . . . . . . .11A CN4(X or X6)-4230xx . . . . . . . .3D DJF 122406 . . . . . . . . . . . . . .5A FVPPM120NR-IMCRD-FS/FS .7A CGP 94938 . . . . . . . . . . . . . .11A CN4(X or X6)-4236xx . . . . . . . .3D DJF 122408 . . . . . . . . . . . . . .5A FVPPM12-IMCRD-FS . . . . . . .7A CGP 94938-M . . . . . . . . . . . .11A CN4(X or X6)-482408 . . . . . . .3D DJF 123006 . . . . . . . . . . . . . .5A FVPPM12-IMCRD-FS/FS . . . . .7A CGP 951000 . . . . . . . . . . . . .11A CN4(X or X6)-4830xx . . . . . . . .3D DJF 123208 . . . . . . . . . . . . . .5A FVPPM24-IMCRD-FS . . . . . . .7A CGP 951000-M . . . . . . . . . . .11A CN4(X or X6)-4836xx . . . . . . . .3D DJF 123608 . . . . . . . . . . . . . .5A FVPPM24-IMCRD-FS/FS . . . . .7A CGP 951125 . . . . . . . . . . . . .11A CN4(X or X6)-6036xx . . . . . . . .3D FDO . . . . . . . . . . . . . . . . . . . .5E FVPPM6-IMCRD-FS . . . . . . . .7A CGP 951125-M . . . . . . . . . . .11A Color adder for legend plates .7A FL 92 . . . . . . . . . . . . . . . . . .10A FVPPM6-IMCRD-FS/FS . . . . . .7A CGP 951250 . . . . . . . . . . . . .11A CV-20 1-3/C . . . . . . . . . . . . . .11A FL 93 . . . . . . . . . . . . . . . . . .10A FVPPT120NFS . . . . . . . . . . . .7A CGP 951250-M . . . . . . . . . . .11A CV-20 3-1/C . . . . . . . . . . . . . .11A FL 94 . . . . . . . . . . . . . . . . . .10A FVPTT120FS . . . . . . . . . . . . . .7A CGP 951375 . . . . . . . . . . . . .11A CV-25 1-3/C . . . . . . . . . . . . . .11A FL 96 . . . . . . . . . . . . . . . . . .10A FVPTT12FS . . . . . . . . . . . . . . .7A CGP 951375-M . . . . . . . . . . .11A CV-25 3-1/C . . . . . . . . . . . . . .11A FS 21 . . . . . . . . . . . . . . . . . . .5E FVPTT24FS . . . . . . . . . . . . . . .7A CGP 95875 . . . . . . . . . . . . . .11A CV-30 1-3/C . . . . . . . . . . . . . .11A FS20 . . . . . . . . . . . . . . . . . . .11A FVPTT6FS . . . . . . . . . . . . . . . .7A CGP 961000 . . . . . . . . . . . . .11A CV-30 3-1/C . . . . . . . . . . . . . .11A FS25 . . . . . . . . . . . . . . . . . . .11A FVPTTFS . . . . . . . . . . . . . . . . .7A CGP 961000-M . . . . . . . . . . .11A CV-35 1-3/C . . . . . . . . . . . . . .11A FS30 . . . . . . . . . . . . . . . . . . .11A GHG 418 8131 R0014 . . . . . . .3D CGP 961125 . . . . . . . . . . . . .11A CV-35 3-1/C . . . . . . . . . . . . . .11A FS35 . . . . . . . . . . . . . . . . . . .11A GHG 418 8131 R0015 . . . . . . .3D CGP 961125-M . . . . . . . . . . .11A CV-40 1-3/C . . . . . . . . . . . . . .11A FS40 . . . . . . . . . . . . . . . . . . .11A GHG 418 8131 R0016 . . . . . . .3D CGP 961250 . . . . . . . . . . . . .11A CV-40 3-1/C . . . . . . . . . . . . . .11A FS-50 . . . . . . . . . . . . . . . . . .11A GT-100F 5-50-8 . . . . . . . . . . .11A CGP 961250-M . . . . . . . . . . .11A CV-50 1-3/C . . . . . . . . . . . . . .11A FS525 . . . . . . . . . . . . . . . . . .11A HV4X6-161606 . . . . . . . . . . . .3C CGP 961375 . . . . . . . . . . . . .11A CV-50 3-1/C . . . . . . . . . . . . . .11A FS535 . . . . . . . . . . . . . . . . . .11A HV4X6-201206 . . . . . . . . . . . .3C CGP 961375-M . . . . . . . . . . .11A CV-60 1-3/C . . . . . . . . . . . . . .11A FS540 . . . . . . . . . . . . . . . . . .11A HV4X6-201407 . . . . . . . . . . . .3C CGP 96875 . . . . . . . . . . . . . .11A CV-60 3-1/C . . . . . . . . . . . . . .11A FSBT . . . . . . . . . . . . . . . . . . . .7A HV4X6-201610 . . . . . . . . . . . .3C CGP 981250 . . . . . . . . . . . . .11A CVS-20 1-3/C . . . . . . . . . . . . .11A FSD . . . . . . . . . . . . . . . . . . .11A HV4X6-202006 . . . . . . . . . . . .3C CGP 981562 . . . . . . . . . . . . .11A CVS-20 3-1/C . . . . . . . . . . . . .11A FSD-35 . . . . . . . . . . . . . . . . .11A HV4X6-202008 . . . . . . . . . . . .3C CGP 981562-M . . . . . . . . . . .11A CVS-25 1-3/C . . . . . . . . . . . . .11A FSDG-31 . . . . . . . . . . . . . . . .11A HV4X6-202010 . . . . . . . . . . . .3C CGP 981688 . . . . . . . . . . . . .11A CVS-25 3-1/C . . . . . . . . . . . . .11A FSDG-32 . . . . . . . . . . . . . . . .11A HV4X6-241206 . . . . . . . . . . . .3C CGP 981688-M . . . . . . . . . . .11A CVS-30 1-3/C . . . . . . . . . . . . .11A FSDP-3 . . . . . . . . . . . . . . . . .11A HV4X6-241606 . . . . . . . . . . . .3C CGP 981812 . . . . . . . . . . . . .11A CVS-30 3-1/C . . . . . . . . . . . . .11A FSDP-35 . . . . . . . . . . . . . . . .11A HV4X6-242006 . . . . . . . . . . . .3C CGP 981812-M . . . . . . . . . . .11A CVS-35 1-3/C . . . . . . . . . . . . .11A FSDS-1 . . . . . . . . . . . . . . . . .11A HV4X6-242008 . . . . . . . . . . . .3C CN4(X or X6)-1224xx . . . . . . . .3D CVS-35 3-1/C . . . . . . . . . . . . .11A FSDS-2 . . . . . . . . . . . . . . . . .11A HV4X6-242010 . . . . . . . . . . . .3C CN4(X or X6)-1612xx . . . . . . . .3D CVS-40 1-3/C . . . . . . . . . . . . .11A FSDS-35 . . . . . . . . . . . . . . . .11A HV4X6-242010 . . . . . . . . . . . .3C CN4(X or X6)-1616xx . . . . . . . .3D CVS-40 3-1/C . . . . . . . . . . . . .11A FSH 2 . . . . . . . . . . . . . . . . . . .5E HV4X6-242408 . . . . . . . . . . . .3C CN4(X or X6)-1620xx . . . . . . . .3D CVS-50 1-3/C . . . . . . . . . . . . .11A FSH 3 . . . . . . . . . . . . . . . . . . .5E HV4X6-242410 . . . . . . . . . . . .3C CN4(X or X6)-2012xx . . . . . . . .3D CVS-50 3-1/C . . . . . . . . . . . . .11A FSO . . . . . . . . . . . . . . . . . . . .5E HV4X6-242410 . . . . . . . . . . . .3C 361 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 362 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX HV4X6-251807 . . . . . . . . . . . .3C JAG 423-40 . . . . . . . . . . . . . .11A JH 121810 . . . . . . . . . . . . . . .5D JN4XSS-101006 . . . . . . . . . . .1A HV4X6-301606 . . . . . . . . . . . .3C JAG 437-40 . . . . . . . . . . . . . .11A JH 122406 . . . . . . . . . . . . . . .5D JN4XSS-121005 . . . . . . . . . . .1A HV4X6-302010 . . . . . . . . . . . .3C JAG 45-05 . . . . . . . . . . . . . . .11A JH 122408 . . . . . . . . . . . . . . .5D JN4XSS-121008 . . . . . . . . . . .1A HV4X6-302010 . . . . . . . . . . . .3C JAG 451-40 . . . . . . . . . . . . . .11A JH 123606 . . . . . . . . . . . . . . .5D JN4XSS-121206 . . . . . . . . . . .1A HV4X6-302207 . . . . . . . . . . . .3C JAG 462-40 . . . . . . . . . . . . . .11A JH 141406 . . . . . . . . . . . . . . .5D JN4XSS-140806 . . . . . . . . . . .1A HV4X6-302410 . . . . . . . . . . . .3C JAG 55-05 . . . . . . . . . . . . . . .11A JH 151508 . . . . . . . . . . . . . . .5D JN4XSS-141206 . . . . . . . . . . .1A HV4X6-302410 . . . . . . . . . . . .3C JAG 65-05 . . . . . . . . . . . . . . .11A JH 181806 . . . . . . . . . . . . . . .5D JN4XSS-141208 . . . . . . . . . . .1A HV4X6-362410 . . . . . . . . . . . .3C JAG 75-05 . . . . . . . . . . . . . . .11A JH 181808 . . . . . . . . . . . . . . .5D JN4XSS-161406 . . . . . . . . . . .1A HV4X6-362410 . . . . . . . . . . . .3C JAG 85-05 . . . . . . . . . . . . . . .11A JH 181810 . . . . . . . . . . . . . . .5D JN4XSS-161408 . . . . . . . . . . .1A HV4X6-362507 . . . . . . . . . . . .3C JAG 95-05 . . . . . . . . . . . . . . .11A JH 181812 . . . . . . . . . . . . . . .5D JN4XSS-161410 . . . . . . . . . . .1A HV4X6-362510 . . . . . . . . . . . .3C JAG 99-07 . . . . . . . . . . . . . . .11A JH 182408 . . . . . . . . . . . . . . .5D JP 020401 . . . . . . . . . . . . . . .5D HV4X6-362510 . . . . . . . . . . . .3C JF 060604 . . . . . . . . . . . . . . .5D JH 183606 . . . . . . . . . . . . . . .5D JP 030302 . . . . . . . . . . . . . . .5D HV4X6-603610 . . . . . . . . . . . .3C JF 060606 . . . . . . . . . . . . . . .5D JH 183608 . . . . . . . . . . . . . . .5D JP 030303 . . . . . . . . . . . . . . .5D HV4X6-603610 . . . . . . . . . . . .3C JF 060804 . . . . . . . . . . . . . . .5D JH 242408 . . . . . . . . . . . . . . .5D JP 040403 . . . . . . . . . . . . . . .5D HV4X6-603616 . . . . . . . . . . . .3C JF 060806 . . . . . . . . . . . . . . .5D JH 243008 . . . . . . . . . . . . . . .5D JP 040404 . . . . . . . . . . . . . . .5D IPBCAR . . . . . . . . . . . . . . . . . .7A JF 061206 . . . . . . . . . . . . . . .5D JH 243606 . . . . . . . . . . . . . . .5D JP 040603 . . . . . . . . . . . . . . .5D IPBCBE . . . . . . . . . . . . . . . . . .7A JF 080804 . . . . . . . . . . . . . . .5D JH 243608 . . . . . . . . . . . . . . .5D JP 040604 . . . . . . . . . . . . . . .5D IPBCCR . . . . . . . . . . . . . . . . . .7A JF 080806 . . . . . . . . . . . . . . .5D JH 243612 . . . . . . . . . . . . . . .5D JP 040804 . . . . . . . . . . . . . . .5D IPBCGN . . . . . . . . . . . . . . . . .7A JF 081206 . . . . . . . . . . . . . . .5D JN4XHA-060604 . . . . . . . . . . .1B JP 041204 . . . . . . . . . . . . . . .5D IPBCRD . . . . . . . . . . . . . . . . .7A JF 121206 . . . . . . . . . . . . . . .5D JN4XHA-080604 . . . . . . . . . . .1B JP 060603 . . . . . . . . . . . . . . .5D IPBCWE . . . . . . . . . . . . . . . . .7A JF 121208 . . . . . . . . . . . . . . .5D JN4XHA-100804 . . . . . . . . . . .1B JP 060604 . . . . . . . . . . . . . . .5D JAG 107-07 . . . . . . . . . . . . . .11A JF 121810 . . . . . . . . . . . . . . .5D JN4XHA-121005 . . . . . . . . . . .1B JP 060606 . . . . . . . . . . . . . . .5D JAG 112-10 . . . . . . . . . . . . . .11A JF 122406 . . . . . . . . . . . . . . .5D JN4XHA-141206 . . . . . . . . . . .1B JP 060804 . . . . . . . . . . . . . . .5D JAG 113-07 . . . . . . . . . . . . . .11A JF 122408 . . . . . . . . . . . . . . .5D JN4XHA-161406 . . . . . . . . . . .1B JP 060806 . . . . . . . . . . . . . . .5D JAG 121-07 . . . . . . . . . . . . . .11A JF 183608 . . . . . . . . . . . . . . .5D JN4XHSS-060403 . . . . . . . . . .1A JP 061004 . . . . . . . . . . . . . . .5D JAG 125-10 . . . . . . . . . . . . . .11A JH 060604 . . . . . . . . . . . . . . .5D JN4XHSS-060404 . . . . . . . . . .1A JP 061204 . . . . . . . . . . . . . . .5D JAG 138-10 . . . . . . . . . . . . . .11A JH 060606 . . . . . . . . . . . . . . .5D JN4XHSS-060604 . . . . . . . . . .1A JP 061206 . . . . . . . . . . . . . . .5D JAG 138-12 . . . . . . . . . . . . . .11A JH 060804 . . . . . . . . . . . . . . .5D JN4XHSS-080604 . . . . . . . . . .1A JP 080804 . . . . . . . . . . . . . . .5D JAG 156-12 . . . . . . . . . . . . . .11A JH 060806 . . . . . . . . . . . . . . .5D JN4XHSS-080606 . . . . . . . . . .1A JP 080806 . . . . . . . . . . . . . . .5D JAG 174-12 . . . . . . . . . . . . . .11A JH 061004 . . . . . . . . . . . . . . .5D JN4XHSS-080804 . . . . . . . . . .1A JP 080808 . . . . . . . . . . . . . . .5D JAG 174-15 . . . . . . . . . . . . . .11A JH 061204 . . . . . . . . . . . . . . .5D JN4XHSS-100804 . . . . . . . . . .1A JP 081004 . . . . . . . . . . . . . . .5D JAG 188-12 . . . . . . . . . . . . . .11A JH 061206 . . . . . . . . . . . . . . .5D JN4XHSS-100806 . . . . . . . . . .1A JP 081006 . . . . . . . . . . . . . . .5D JAG 188-15 . . . . . . . . . . . . . .11A JH 080804 . . . . . . . . . . . . . . .5D JN4XHSS-101006 . . . . . . . . . .1A JP 081008 . . . . . . . . . . . . . . .5D JAG 200-15 . . . . . . . . . . . . . .11A JH 080806 . . . . . . . . . . . . . . .5D JN4XHSS-121005 . . . . . . . . . .1A JP 081204 . . . . . . . . . . . . . . .5D JAG 218-15 . . . . . . . . . . . . . .11A JH 080808 . . . . . . . . . . . . . . .5D JN4XHSS-121008 . . . . . . . . . .1A JP 081206 . . . . . . . . . . . . . . .5D JAG 219-20 . . . . . . . . . . . . . .11A JH 081004 . . . . . . . . . . . . . . .5D JN4XHSS-121206 . . . . . . . . . .1A JP 101204 . . . . . . . . . . . . . . .5D JAG 236-20 . . . . . . . . . . . . . .11A JH 081006 . . . . . . . . . . . . . . .5D JN4XHSS-140806 . . . . . . . . . .1A JP 101206 . . . . . . . . . . . . . . .5D JAG 247-20 . . . . . . . . . . . . . .11A JH 081008 . . . . . . . . . . . . . . .5D JN4XHSS-141206 . . . . . . . . . .1A JP 101208 . . . . . . . . . . . . . . .5D JAG 261-20 . . . . . . . . . . . . . .11A JH 081204 . . . . . . . . . . . . . . .5D JN4XHSS-141208 . . . . . . . . . .1A JP 121204 . . . . . . . . . . . . . . .5D JAG 263-25 . . . . . . . . . . . . . .11A JH 081206 . . . . . . . . . . . . . . .5D JN4XHSS-161406 . . . . . . . . . .1A JP 121206 . . . . . . . . . . . . . . .5D JAG 280-25 . . . . . . . . . . . . . .11A JH 101204 . . . . . . . . . . . . . . .5D JN4XHSS-161408 . . . . . . . . . .1A JP 121208 . . . . . . . . . . . . . . .5D JAG 296-25 . . . . . . . . . . . . . .11A JH 101206 . . . . . . . . . . . . . . .5D JN4XHSS-161410 . . . . . . . . . .1A JP 121604 . . . . . . . . . . . . . . .5D JAG 297-30 . . . . . . . . . . . . . .11A JH 101208 . . . . . . . . . . . . . . .5D JN4XSS-060403 . . . . . . . . . . .1A JP 121606 . . . . . . . . . . . . . . .5D JAG 311-30 . . . . . . . . . . . . . .11A JH 121204 . . . . . . . . . . . . . . .5D JN4XSS-060404 . . . . . . . . . . .1A JP 121608 . . . . . . . . . . . . . . .5D JAG 327-30 . . . . . . . . . . . . . .11A JH 121206 . . . . . . . . . . . . . . .5D JN4XSS-060604 . . . . . . . . . . .1A JP 121806 . . . . . . . . . . . . . . .5D JAG 343-30 . . . . . . . . . . . . . .11A JH 121208 . . . . . . . . . . . . . . .5D JN4XSS-080604 . . . . . . . . . . .1A JP 121810 . . . . . . . . . . . . . . .5D JAG 359-30 . . . . . . . . . . . . . .11A JH 121604 . . . . . . . . . . . . . . .5D JN4XSS-080606 . . . . . . . . . . .1A JP 122406 . . . . . . . . . . . . . . .5D JAG 375-35 . . . . . . . . . . . . . .11A JH 121606 . . . . . . . . . . . . . . .5D JN4XSS-080804 . . . . . . . . . . .1A JP 122408 . . . . . . . . . . . . . . .5D JAG 392-35 . . . . . . . . . . . . . .11A JH 121608 . . . . . . . . . . . . . . .5D JN4XSS-100804 . . . . . . . . . . .1A JP 123606 . . . . . . . . . . . . . . .5D JAG 412-35 . . . . . . . . . . . . . .11A JH 121806 . . . . . . . . . . . . . . .5D JN4XSS-100806 . . . . . . . . . . .1A JP 141406 . . . . . . . . . . . . . . .5D 362 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 363 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section JP 151508 . . . . . . . . . . . . . . .5D KOSRLRC-KL-FS . . . . . . . . . . .7A KOSS3-KLR-FS/FS . . . . . . . . . .7A N4X(or N4X6)-302408 . . . . . . .1A JP 181806 . . . . . . . . . . . . . . .5D KOSRLRC-KL-FS/FS . . . . . . . .7A KOSS3-KRC-FS . . . . . . . . . . . .7A N4X(or N4X6)-302410 . . . . . . .1A JP 181808 . . . . . . . . . . . . . . .5D KOSRLRC-KL-FS/FS . . . . . . . .7A KOSS3-KRC-FS/FS . . . . . . . . .7A N4X(or N4X6)-302412 . . . . . . .1A JP 181810 . . . . . . . . . . . . . . .5D KOSRLRC-KLR-FS . . . . . . . . . .7A KOSS3-KR-FS . . . . . . . . . . . . .7A N4X(or N4X6)-302416 . . . . . . .1A JP 181812 . . . . . . . . . . . . . . .5D KOSRLRC-KLR-FS . . . . . . . . . .7A KOSS3-KR-FS/FS . . . . . . . . . . .7A N4X(or N4X6)-302420 . . . . . . .1A JP 182408 . . . . . . . . . . . . . . .5D KOSRLRC-KLR-FS/FS . . . . . . .7A KOSS4-FS . . . . . . . . . . . . . . . .7A N4X(or N4X6)-302424 . . . . . . .1A JP 183606 . . . . . . . . . . . . . . .5D KOSRLRC-KLR-FS/FS . . . . . . .7A KOSS4-FS/FS . . . . . . . . . . . . .7A N4X(or N4X6)-303008 . . . . . . .1A JP 183608 . . . . . . . . . . . . . . .5D KOSRLRC-KRC-FS . . . . . . . . .7A LP, LPN, LPS . . . . . . . . . . . . . .7A N4X(or N4X6)-303012 . . . . . . .1A JP 242408 . . . . . . . . . . . . . . .5D KOSRLRC-KRC-FS . . . . . . . . .7A LPB . . . . . . . . . . . . . . . . . . . .11A N4X(or N4X6)-362406 . . . . . . .1A JP 242410 . . . . . . . . . . . . . . .5D KOSRLRC-KRC-FS/FS . . . . . . .7A LPC . . . . . . . . . . . . . . . . . . . .11A N4X(or N4X6)-362408 . . . . . . .1A JP 243008 . . . . . . . . . . . . . . .5D KOSRLRC-KRC-FS/FS . . . . . . .7A LPD . . . . . . . . . . . . . . . . . . .11A N4X(or N4X6)-362410 . . . . . . .1A JP 243606 . . . . . . . . . . . . . . .5D KOSRLRC-KR-FS . . . . . . . . . . .7A LPE . . . . . . . . . . . . . . . . . . . .11A N4X(or N4X6)-362412 . . . . . . .1A JP 243608 . . . . . . . . . . . . . . .5D KOSRLRC-KR-FS . . . . . . . . . . .7A M1423 . . . . . . . . . . . . . . . . . .1C N4X(or N4X6)-363006 . . . . . . .1A JP 243612 . . . . . . . . . . . . . . .5D KOSRLRC-KR-FS/FS . . . . . . . .7A MFL 92 . . . . . . . . . . . . . . . . .10A N4X(or N4X6)-363008 . . . . . . .1A JP 363612 . . . . . . . . . . . . . . .5D KOSRLRC-KR-FS/FS . . . . . . . .7A MFL 93 . . . . . . . . . . . . . . . . .10A N4X(or N4X6)-363010 . . . . . . .1A JR 040404 . . . . . . . . . . . . . . .5D KOSRRC-FS . . . . . . . . . . . . . .7A MFL 94 . . . . . . . . . . . . . . . . .10A N4X(or N4X6)-363012 . . . . . . .1A JR 040604 . . . . . . . . . . . . . . .5D KOSRRC-FS/FS . . . . . . . . . . . .7A MFL 95 . . . . . . . . . . . . . . . . .10A N4X(or N4X6)-363016 . . . . . . .1A JR 060604 . . . . . . . . . . . . . . .5D KOSRRC-KC-FS . . . . . . . . . . . .7A MFL 96 . . . . . . . . . . . . . . . . .10A N4X(or N4X6)-363020 . . . . . . .1A JR 060606 . . . . . . . . . . . . . . .5D KOSRRC-KC-FS/FS . . . . . . . . .7A N4X(or N4X6)-161206 . . . . . . .1A N4X(or N4X6)-363608 . . . . . . .1A JR 060804 . . . . . . . . . . . . . . .5D KOSRRC-KLC-FS . . . . . . . . . . .7A N4X(or N4X6)-161208 . . . . . . .1A N4X(or N4X6)-363612 . . . . . . .1A JR 060806 . . . . . . . . . . . . . . .5D KOSRRC-KLC-FS/FS . . . . . . . .7A N4X(or N4X6)-161606 . . . . . . .1A N4X(or N4X6)-423008 . . . . . . .1A JR 061006 . . . . . . . . . . . . . . .5D KOSRRC-KL-FS . . . . . . . . . . . .7A N4X(or N4X6)-161608 . . . . . . .1A N4X(or N4X6)-423010 . . . . . . .1A JR 061206 . . . . . . . . . . . . . . .5D KOSRRC-KL-FS/FS . . . . . . . . .7A N4X(or N4X6)-162006 . . . . . . .1A N4X(or N4X6)-423012 . . . . . . .1A JR 080804 . . . . . . . . . . . . . . .5D KOSRRC-KLR-FS . . . . . . . . . . .7A N4X(or N4X6)-162008 . . . . . . .1A N4X(or N4X6)-423608 . . . . . . .1A JR 080806 . . . . . . . . . . . . . . .5D KOSRRC-KLR-FS/FS . . . . . . . .7A N4X(or N4X6)-201606 . . . . . . .1A N4X(or N4X6)-423610 . . . . . . .1A JR 080808 . . . . . . . . . . . . . . .5D KOSRRC-KRC-FS . . . . . . . . . .7A N4X(or N4X6)-201608 . . . . . . .1A N4X(or N4X6)-423612 . . . . . . .1A JR 081206 . . . . . . . . . . . . . . .5D KOSRRC-KRC-FS/FS . . . . . . . .7A N4X(or N4X6)-201610 . . . . . . .1A N4X(or N4X6)-423616 . . . . . . .1A JR 101006 . . . . . . . . . . . . . . .5D KOSRRC-KR-FS . . . . . . . . . . . .7A N4X(or N4X6)-201612 . . . . . . .1A N4X(or N4X6)-483608 . . . . . . .1A JR 121206 . . . . . . . . . . . . . . .5D KOSRRC-KR-FS/FS . . . . . . . . .7A N4X(or N4X6)-202006 . . . . . . .1A N4X(or N4X6)-483610 . . . . . . .1A JR 121208 . . . . . . . . . . . . . . .5D KOSRRL-FS . . . . . . . . . . . . . .7A N4X(or N4X6)-202008 . . . . . . .1A N4X(or N4X6)-483612 . . . . . . .1A JR 121810 . . . . . . . . . . . . . . .5D KOSRRL-FS/FS . . . . . . . . . . . .7A N4X(or N4X6)-202010 . . . . . . .1A N4X(or N4X6)-483616 . . . . . . .1A JR 122406 . . . . . . . . . . . . . . .5D KOSRRL-FS/FS-KL . . . . . . . . .7A N4X(or N4X6)-202406 . . . . . . .1A N4X(or N4X6)-483620 . . . . . . .1A JR 161606 . . . . . . . . . . . . . . .5D KOSRRL-FS-KL . . . . . . . . . . . .7A N4X(or N4X6)-202408 . . . . . . .1A N4X(or N4X6)-603610 . . . . . . .1A JR 161808 . . . . . . . . . . . . . . .5D KOSS2-FS . . . . . . . . . . . . . . . .7A N4X(or N4X6)-241206 . . . . . . .1A N4X(or N4X6)-603612 . . . . . . .1A JR 161810 . . . . . . . . . . . . . . .5D KOSS2-FS/FS . . . . . . . . . . . . .7A N4X(or N4X6)-241606 . . . . . . .1A N4X(or N4X6)-603616 . . . . . . .1A JR 181812 . . . . . . . . . . . . . . .5D KOSS2-KL-FS . . . . . . . . . . . . .7A N4X(or N4X6)-241608 . . . . . . .1A N4X(or N4X6)-603620 . . . . . . .1A JR 183608 . . . . . . . . . . . . . . .5D KOSS2-KL-FS/FS . . . . . . . . . . .7A N4X(or N4X6)-242006 . . . . . . .1A N4XA-161206 . . . . . . . . . . . . .1B KOSRLC-FS . . . . . . . . . . . . . .7A KOSS2-KLR-FS . . . . . . . . . . . .7A N4X(or N4X6)-242008 . . . . . . .1A N4XA-161608 . . . . . . . . . . . . .1B KOSRLC-FS/FS . . . . . . . . . . . .7A KOSS2-KLR-FS/FS . . . . . . . . . .7A N4X(or N4X6)-242010 . . . . . . .1A N4XA-201606 . . . . . . . . . . . . .1B KOSRLRC-FS . . . . . . . . . . . . .7A KOSS2-KR-FS . . . . . . . . . . . . .7A N4X(or N4X6)-242012 . . . . . . .1A N4XA-201610 . . . . . . . . . . . . .1B KOSRLRC-FS/FS . . . . . . . . . . .7A KOSS2-KR-FS/FS . . . . . . . . . . .7A N4X(or N4X6)-242016 . . . . . . .1A N4XA-202006 . . . . . . . . . . . . .1B KOSRLRC-KC-FS . . . . . . . . . . .7A KOSS3-FS . . . . . . . . . . . . . . . .7A N4X(or N4X6)-242406 . . . . . . .1A N4XA-242006 . . . . . . . . . . . . .1B KOSRLRC-KC-FS . . . . . . . . . . .7A KOSS3-FS/FS . . . . . . . . . . . . .7A N4X(or N4X6)-242408 . . . . . . .1A N4XA-242010 . . . . . . . . . . . . .1B KOSRLRC-KC-FS/FS . . . . . . . .7A KOSS3-KC-FS . . . . . . . . . . . . .7A N4X(or N4X6)-242410 . . . . . . .1A N4XA-242408 . . . . . . . . . . . . .1B KOSRLRC-KC-FS/FS . . . . . . . .7A KOSS3-KC-FS/FS . . . . . . . . . . .7A N4X(or N4X6)-242412 . . . . . . .1A N4XA-302408 . . . . . . . . . . . . .1B KOSRLRC-KLC-FS . . . . . . . . . .7A KOSS3-KLC-FS . . . . . . . . . . . .7A N4X(or N4X6)-242416 . . . . . . .1A N4XA-302412 . . . . . . . . . . . . .1B KOSRLRC-KLC-FS . . . . . . . . . .7A KOSS3-KLC-FS/FS . . . . . . . . . .7A N4X(or N4X6)-243008 . . . . . . .1A N4XA-362408 . . . . . . . . . . . . .1B KOSRLRC-KLC-FS/FS . . . . . . .7A KOSS3-KL-FS . . . . . . . . . . . . .7A N4X(or N4X6)-302006 . . . . . . .1A N4XA-363008 . . . . . . . . . . . . .1B KOSRLRC-KLC-FS/FS . . . . . . .7A KOSS3-KL-FS/FS . . . . . . . . . . .7A N4X(or N4X6)-302008 . . . . . . .1A N4XA-363012 . . . . . . . . . . . . .1B KOSRLRC-KL-FS . . . . . . . . . . .7A KOSS3-KLR-FS . . . . . . . . . . . .7A N4X(or N4X6)-302406 . . . . . . .1A N4XA-483608 . . . . . . . . . . . . .1B 363 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 364 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX N4X-DD-SS-604812 . . . . . . . . .1A N4X-FG-201608CH . . . . . . . . .2A PBO-MCGN-FS . . . . . . . . . . . .7A PEML 6 . . . . . . . . . . . . . . . . .10A N4X-DD-SS-606012 . . . . . . . . .1A N4X-FG-201608CHQR . . . . . . .2A PBO-MCGN-FS/FS . . . . . . . . .7A PEML 8 . . . . . . . . . . . . . . . . .10A N4X-DD-SS-726012 . . . . . . . . .1A N4X-FG-201608CHTL . . . . . . .2A PBO-MCRD-FS . . . . . . . . . . . .7A PES 10 . . . . . . . . . . . . . . . . .10A N4X-DD-SS-727212 . . . . . . . . .1A N4X-FG-201610RCHQR . . . . .2A PBO-MCRD-FS/FS . . . . . . . . .7A PES 12 . . . . . . . . . . . . . . . . .10A N4X-FG-030302 . . . . . . . . . . . .2A N4X-FG-201612CH . . . . . . . . .2A PBO-PPMCBK-FS . . . . . . . . . .7A PES 14 . . . . . . . . . . . . . . . . .10A N4X-FG-050302 . . . . . . . . . . . .2A N4X-FG-242008CH . . . . . . . . .2A PBO-PPMCBK-FS/FS . . . . . . . .7A PES 16 . . . . . . . . . . . . . . . . .10A N4X-FG-060404 . . . . . . . . . . . .2A N4X-FG-242410CH . . . . . . . . .2A PBO-PPMCGN-FS . . . . . . . . . .7A PES 2 . . . . . . . . . . . . . . . . . .10A N4X-FG-060604CHQR . . . . . . .2A N4X-FG-2PB . . . . . . . . . . . . . .2A PBO-PPMCGN-FS/FS . . . . . . .7A PES 3 . . . . . . . . . . . . . . . . . .10A N4X-FG-060604CHSC . . . . . . .2A N4X-FG-302410CH . . . . . . . . .2A PBO-PPMCRD-FS . . . . . . . . . .7A PES 4 . . . . . . . . . . . . . . . . . .10A N4X-FG-060604CHTL . . . . . . .2A N4X-FG-302412CH . . . . . . . . .2A PBO-PPMCRD-FS/FS . . . . . . .7A PES 5 . . . . . . . . . . . . . . . . . .10A N4X-FG-060604SC . . . . . . . . .2A N4X-FG-363010CH . . . . . . . . .2A PBO-PPMCYW-FS . . . . . . . . .7A PES 6 . . . . . . . . . . . . . . . . . .10A N4X-FG-070603 . . . . . . . . . . . .2A N4X-FG-363012CH . . . . . . . . .2A PBO-PPMCYW-FS/FS . . . . . . .7A PES 8 . . . . . . . . . . . . . . . . . .10A N4X-FG-080404 . . . . . . . . . . . .2A N4X-FG-3PB . . . . . . . . . . . . . .2A PBO-XCBK-FS . . . . . . . . . . . . .7A PET 10 . . . . . . . . . . . . . . . . .10A N4X-FG-080604CHQR . . . . . . .2A N4X-FG-483616CH . . . . . . . . .2A PBO-XCBK-FS/FS . . . . . . . . . .7A PET 12 . . . . . . . . . . . . . . . . .10A N4X-FG-080604CHSC . . . . . . .2A OX 10 . . . . . . . . . . . . . . . . . .10A PBO-XCGN-FS . . . . . . . . . . . .7A PET 14 . . . . . . . . . . . . . . . . .10A N4X-FG-080604CHTL . . . . . . .2A OX 12 . . . . . . . . . . . . . . . . . .10A PBO-XCGN-FS/FS . . . . . . . . . .7A PET 16 . . . . . . . . . . . . . . . . .10A N4X-FG-080604SC . . . . . . . . .2A OX 14 . . . . . . . . . . . . . . . . . .10A PBO-XCRD-FS . . . . . . . . . . . . .7A PET 2 . . . . . . . . . . . . . . . . . .10A N4X-FG-080606RCHQR . . . . .2A OX 16 . . . . . . . . . . . . . . . . . .10A PBO-XCRD-FS/FS . . . . . . . . . .7A PET 3 . . . . . . . . . . . . . . . . . .10A N4X-FG-090603 . . . . . . . . . . . .2A OX 2 . . . . . . . . . . . . . . . . . . .10A PCK-100 . . . . . . . . . . . . . . . .11A PET 4 . . . . . . . . . . . . . . . . . .10A N4X-FG-100804CHQR . . . . . . .2A OX 3 . . . . . . . . . . . . . . . . . . .10A PCL-128 . . . . . . . . . . . . . . . .11A PET 5 . . . . . . . . . . . . . . . . . .10A N4X-FG-100804CHSC . . . . . . .2A OX 4 . . . . . . . . . . . . . . . . . . .10A PCL-2 . . . . . . . . . . . . . . . . . .11A PET 6 . . . . . . . . . . . . . . . . . .10A N4X-FG-100804CHTL . . . . . . .2A OX 5 . . . . . . . . . . . . . . . . . . .10A PCL-32 . . . . . . . . . . . . . . . . .11A PET 8 . . . . . . . . . . . . . . . . . .10A N4X-FG-100804SC . . . . . . . . .2A OX 6 . . . . . . . . . . . . . . . . . . .10A PE 10 . . . . . . . . . . . . . . . . . .10A PLCK-35 . . . . . . . . . . . . . . . .11A N4X-FG-100806RCHQR . . . . .2A OX 8 . . . . . . . . . . . . . . . . . . .10A PE 12 . . . . . . . . . . . . . . . . . .10A PLLAR . . . . . . . . . . . . . . . . . .7A N4X-FG-100806RCHTL . . . . . .2A PBO-AFCBK-FS . . . . . . . . . . . .7A PE 14 . . . . . . . . . . . . . . . . . .10A PLLBE . . . . . . . . . . . . . . . . . . .7A N4X-FG-110404 . . . . . . . . . . . .2A PBO-AFCBK-FS/FS . . . . . . . . .7A PE 16 . . . . . . . . . . . . . . . . . .10A PLLCR . . . . . . . . . . . . . . . . . .7A N4X-FG-121005CHQR . . . . . . .2A PBO-AFCGN-FS . . . . . . . . . . .7A PE 2 . . . . . . . . . . . . . . . . . . .10A PLLGN . . . . . . . . . . . . . . . . . .7A N4X-FG-121005CHSC . . . . . . .2A PBO-AFCGN-FS/FS . . . . . . . . .7A PE 3 . . . . . . . . . . . . . . . . . . .10A PLLRD . . . . . . . . . . . . . . . . . .7A N4X-FG-121005CHTL . . . . . . .2A PBO-AFCRD-FS . . . . . . . . . . .7A PE 4 . . . . . . . . . . . . . . . . . . .10A PLLWE . . . . . . . . . . . . . . . . . .7A N4X-FG-121005SC . . . . . . . . .2A PBO-AFCRD-FS/FS . . . . . . . . .7A PE 5 . . . . . . . . . . . . . . . . . . .10A PLM Clean . . . . . . . . . . . . . .11A N4X-FG-121006RCHQR . . . . .2A PBO-AMCBK-FS . . . . . . . . . . .7A PE 6 . . . . . . . . . . . . . . . . . . .10A PM 10 . . . . . . . . . . . . . . . . . .10A N4X-FG-121006RCHTL . . . . . .2A PBO-AMCBK-FS/FS . . . . . . . . .7A PE 8 . . . . . . . . . . . . . . . . . . .10A PM 12 . . . . . . . . . . . . . . . . . .10A N4X-FG-141206CHQR . . . . . . .2A PBO-AMCGN-FS . . . . . . . . . . .7A PEM 10 . . . . . . . . . . . . . . . . .10A PM 14 . . . . . . . . . . . . . . . . . .10A N4X-FG-141206CHSC . . . . . . .2A PBO-AMCGN-FS/FS . . . . . . . .7A PEM 12 . . . . . . . . . . . . . . . . .10A PM 16 . . . . . . . . . . . . . . . . . .10A N4X-FG-141206CHTL . . . . . . .2A PBO-AMCRD-FS . . . . . . . . . . .7A PEM 14 . . . . . . . . . . . . . . . . .10A PM 2 . . . . . . . . . . . . . . . . . . .10A N4X-FG-141206SC . . . . . . . . .2A PBO-AMCRD-FS/FS . . . . . . . .7A PEM 16 . . . . . . . . . . . . . . . . .10A PM 20 . . . . . . . . . . . . . . . . . .10A N4X-FG-141207RCHQR . . . . .2A PBO-AXCBK-FS . . . . . . . . . . . .7A PEM 2 . . . . . . . . . . . . . . . . . .10A PM 24 . . . . . . . . . . . . . . . . . .10A N4X-FG-141207RCHTL . . . . . .2A PBO-AXCBK-FS/FS . . . . . . . . .7A PEM 3 . . . . . . . . . . . . . . . . . .10A PM 3 . . . . . . . . . . . . . . . . . . .10A N4X-FG-161406CHQR . . . . . . .2A PBO-AXCGN-FS . . . . . . . . . . .7A PEM 4 . . . . . . . . . . . . . . . . . .10A PM 4 . . . . . . . . . . . . . . . . . . .10A N4X-FG-161406CHSC . . . . . . .2A PBO-AXCGN-FS/FS . . . . . . . . .7A PEM 5 . . . . . . . . . . . . . . . . . .10A PM 5 . . . . . . . . . . . . . . . . . . .10A N4X-FG-161406CHTL . . . . . . .2A PBO-AXCRD-FS . . . . . . . . . . .7A PEM 6 . . . . . . . . . . . . . . . . . .10A PM 6 . . . . . . . . . . . . . . . . . . .10A N4X-FG-161407RCHQR . . . . .2A PBO-AXCRD-FS/FS . . . . . . . . .7A PEM 8 . . . . . . . . . . . . . . . . . .10A PM 8 . . . . . . . . . . . . . . . . . . .10A N4X-FG-161407RCHTL . . . . . .2A PBO-FCBK-FS . . . . . . . . . . . . .7A PEML 10 . . . . . . . . . . . . . . . .10A PS 065-05 . . . . . . . . . . . . . . .11A N4X-FG-181608CHQR . . . . . . .2A PBO-FCBK-FS/FS . . . . . . . . . .7A PEML 12 . . . . . . . . . . . . . . . .10A PS 075-05 . . . . . . . . . . . . . . .11A N4X-FG-181608CHSC . . . . . . .2A PBO-FCGN-FS . . . . . . . . . . . . .7A PEML 14 . . . . . . . . . . . . . . . .10A PS 085-05 . . . . . . . . . . . . . . .11A N4X-FG-181608CHTL . . . . . . .2A PBO-FCGN-FS/FS . . . . . . . . . .7A PEML 16 . . . . . . . . . . . . . . . .10A PS 100-07 . . . . . . . . . . . . . . .11A N4X-FG-181610RCHQR . . . . .2A PBO-FCRD-FS . . . . . . . . . . . . .7A PEML 2 . . . . . . . . . . . . . . . . .10A PS 115-07 . . . . . . . . . . . . . . .11A N4X-FG-181610RCHTL . . . . . .2A PBO-FCRD-FS/FS . . . . . . . . . .7A PEML 3 . . . . . . . . . . . . . . . . .10A PS 125-10 . . . . . . . . . . . . . . .11A N4X-FG-1PB . . . . . . . . . . . . . .2A PBO-MCBK-FS . . . . . . . . . . . .7A PEML 4 . . . . . . . . . . . . . . . . .10A PS 138-10 . . . . . . . . . . . . . . .11A N4X-FG-201606CH . . . . . . . . .2A PBO-MCBK-FS/FS . . . . . . . . . .7A PEML 5 . . . . . . . . . . . . . . . . .10A PS 150-12 . . . . . . . . . . . . . . .11A 364 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 365 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section PS 168-12 . . . . . . . . . . . . . . .11A RLU120I . . . . . . . . . . . . . . . . .7A SROLR-SHWE-FS/FS . . . . . . .7A TFG-100804H . . . . . . . . . . . . .3B PS 183-15 . . . . . . . . . . . . . . .11A RLU120IFS . . . . . . . . . . . . . . .7A SROLR-SLWE-FS . . . . . . . . . .7A TFG-100804I . . . . . . . . . . . . . .3E PS 200-15 . . . . . . . . . . . . . . .11A RLU120L . . . . . . . . . . . . . . . .7A SROLR-SLWE-FS/FS . . . . . . . .7A TFG-100806 . . . . . . . . . . . . . .3B PS 218-15 . . . . . . . . . . . . . . .11A RLU120LFS . . . . . . . . . . . . . .7A SRORC-SHWE-FS . . . . . . . . . .7A TFG-100806H . . . . . . . . . . . . .3B PSX 065-05 . . . . . . . . . . . . . .11A RLU240I . . . . . . . . . . . . . . . . .7A SRORC-SHWE-FS/FS . . . . . . .7A TFG-100806I . . . . . . . . . . . . . .3E PSX 075-05 . . . . . . . . . . . . . .11A RLU240IFS . . . . . . . . . . . . . . .7A SRORC-SLWE-FS . . . . . . . . . .7A TFG-121005 . . . . . . . . . . . . . .3B PSX 085-05 . . . . . . . . . . . . . .11A RLU240L . . . . . . . . . . . . . . . .7A SRORC-SLWE-FS/FS . . . . . . . .7A TFG-121005H . . . . . . . . . . . . .3B PSX 100-07 . . . . . . . . . . . . . .11A RLU240LFS . . . . . . . . . . . . . .7A SRORL-SHWE-FS . . . . . . . . . .7A TFG-121005I . . . . . . . . . . . . . .3E PSX 115-07 . . . . . . . . . . . . . .11A RLU240N . . . . . . . . . . . . . . . .7A SRORL-SHWE-FS/FS . . . . . . .7A TFG-121006 . . . . . . . . . . . . . .3B PSX 125-10 . . . . . . . . . . . . . .11A RLU240NFS . . . . . . . . . . . . . .7A SRORL-SLWE-FS . . . . . . . . . .7A TFG-121006H . . . . . . . . . . . . .3B PSX 138-10 . . . . . . . . . . . . . .11A RLU480N . . . . . . . . . . . . . . . .7A SRORL-SLWE-FS/FS . . . . . . . .7A TFG-121006I . . . . . . . . . . . . . .3E PSX 150-12 . . . . . . . . . . . . . .11A RLU480NFS . . . . . . . . . . . . . .7A SSF-2 . . . . . . . . . . . . . . . . . .11A TFG-141206 . . . . . . . . . . . . . .3B PSX 168-12 . . . . . . . . . . . . . .11A Round yellow emergency stop 7A SSO2-SHWE-FS . . . . . . . . . . .7A TFG-141206H . . . . . . . . . . . . .3B PSX 183-15 . . . . . . . . . . . . . .11A RTLU120 . . . . . . . . . . . . . . . . .7A SSO2-SHWE-FS/FS . . . . . . . . .7A TFG-141206I . . . . . . . . . . . . . .3E PSX 200-15 . . . . . . . . . . . . . .11A RTLU120FS . . . . . . . . . . . . . . .7A SSO2-SLWE-FS . . . . . . . . . . . .7A TFG-141207 . . . . . . . . . . . . . .3B PSX 218-15 . . . . . . . . . . . . . .11A RTLU240 . . . . . . . . . . . . . . . . .7A SSO2-SLWE-FS/FS . . . . . . . . .7A TFG-141207H . . . . . . . . . . . . .3B PT 1000-D . . . . . . . . . . . . . . .11A RTLU240FS . . . . . . . . . . . . . . .7A SSO3-SHWE-FS . . . . . . . . . . .7A TFG-141207I . . . . . . . . . . . . . .3E PT 10-B . . . . . . . . . . . . . . . . .11A SA 42 . . . . . . . . . . . . . . . . . .10A SSO3-SHWE-FS/FS . . . . . . . . .7A TFG-161406 . . . . . . . . . . . . . .3B PT 1-B . . . . . . . . . . . . . . . . . .11A SD . . . . . . . . . . . . . . . . . . . .11A SSO3-SLWE-FS . . . . . . . . . . . .7A TFG-161406H . . . . . . . . . . . . .3B PT 20-B . . . . . . . . . . . . . . . . .11A SE-15 . . . . . . . . . . . . . . . . . .11A SSO3-SLWE-FS/FS . . . . . . . . .7A TFG-161406I . . . . . . . . . . . . . .3E PT 250-C . . . . . . . . . . . . . . . .11A SE-16 . . . . . . . . . . . . . . . . . .11A SSR . . . . . . . . . . . . . . . . . . .11A TFG-161407 . . . . . . . . . . . . . .3B PT 2-B . . . . . . . . . . . . . . . . . .11A SE-25 . . . . . . . . . . . . . . . . . .11A SW 5050 . . . . . . . . . . . . . . . .11A TFG-161407H . . . . . . . . . . . . .3B PT 300-C . . . . . . . . . . . . . . . .11A SE-35 . . . . . . . . . . . . . . . . . .11A TAP 2015 . . . . . . . . . . . . . . .11A TFG-161407I . . . . . . . . . . . . . .3E PT 30-B . . . . . . . . . . . . . . . . .11A SE-5 . . . . . . . . . . . . . . . . . . .11A TAP 2030 . . . . . . . . . . . . . . .11A TFG-181608 . . . . . . . . . . . . . .3B PT 350-C . . . . . . . . . . . . . . . .11A SE-8 . . . . . . . . . . . . . . . . . . .11A TCK-35 . . . . . . . . . . . . . . . . .11A TFG-181608H . . . . . . . . . . . . .3B PT 400-C . . . . . . . . . . . . . . . .11A SG-1 . . . . . . . . . . . . . . . . . . .11A TCT-2705 . . . . . . . . . . . . . . . .11A TFG-181608I . . . . . . . . . . . . . .3E PT 40-C . . . . . . . . . . . . . . . . .11A SH 1125 . . . . . . . . . . . . . . . .10A TCY-8025 . . . . . . . . . . . . . . .11A TFG-181610 . . . . . . . . . . . . . .3B PT 4-B . . . . . . . . . . . . . . . . . .11A SH 50 . . . . . . . . . . . . . . . . . .10A TFA 45-25 . . . . . . . . . . . . . . .11A TFG-181610H . . . . . . . . . . . . .3B PT 500-C . . . . . . . . . . . . . . . .11A SH 75 . . . . . . . . . . . . . . . . . .10A TFA 45-30 . . . . . . . . . . . . . . .11A TFG-181610I . . . . . . . . . . . . . .3E PT 600-D . . . . . . . . . . . . . . . .11A SHD 50 . . . . . . . . . . . . . . . . .10A TFA 45-35 . . . . . . . . . . . . . . .11A TFG-201608 . . . . . . . . . . . . . .3B PT 6-B . . . . . . . . . . . . . . . . . .11A SHD 75 . . . . . . . . . . . . . . . . .10A TFA 45-40 . . . . . . . . . . . . . . .11A TFG-201608H . . . . . . . . . . . . .3B PT 700-D . . . . . . . . . . . . . . . .11A SHS 1125 . . . . . . . . . . . . . . .10A TFA 45-50 . . . . . . . . . . . . . . .11A TFG-201608I . . . . . . . . . . . . . .3E PT 750-D . . . . . . . . . . . . . . . .11A SHS 50 . . . . . . . . . . . . . . . . .10A TFA 45-60 . . . . . . . . . . . . . . .11A TFG-201610 . . . . . . . . . . . . . .3B PT 8-B . . . . . . . . . . . . . . . . . .11A SHS 75 . . . . . . . . . . . . . . . . .10A TFG-060404 . . . . . . . . . . . . . .3B TFG-201610H . . . . . . . . . . . . .3B PTR-TMCBK-FS . . . . . . . . . . . .7A SPE 2 . . . . . . . . . . . . . . . . . .10A TFG-060404H . . . . . . . . . . . . .3B TFG-201610I . . . . . . . . . . . . . .3E PTR-TMCBK-FS/FS . . . . . . . . .7A SPE 3 . . . . . . . . . . . . . . . . . .10A TFG-060406 . . . . . . . . . . . . . .3B TFLU120 . . . . . . . . . . . . . . . . .7A PTR-TMCGN-FS . . . . . . . . . . .7A SPE 4 . . . . . . . . . . . . . . . . . .10A TFG-060406H . . . . . . . . . . . . .3B TFLU120FS . . . . . . . . . . . . . . .7A PTR-TMCGN-FS/FS . . . . . . . . .7A SPE 5 . . . . . . . . . . . . . . . . . .10A TFG-060604 . . . . . . . . . . . . . .3B TFLU240 . . . . . . . . . . . . . . . . .7A PTR-TMCRD-FS . . . . . . . . . . .7A SPE 6 . . . . . . . . . . . . . . . . . .10A TFG-060604H . . . . . . . . . . . . .3B TFLU240FS . . . . . . . . . . . . . . .7A PTR-TMCRD-FS/FS . . . . . . . . .7A SPE 8 . . . . . . . . . . . . . . . . . .10A TFG-060604I . . . . . . . . . . . . . .3E TFLU277 . . . . . . . . . . . . . . . . .7A PTR-TMCYW-FS . . . . . . . . . . .7A SPLICING BOOK . . . . . . . . . .11A TFG-060606 . . . . . . . . . . . . . .3B TFLU277FS . . . . . . . . . . . . . . .7A PTR-TMCYW-FS/FS . . . . . . . . .7A SROLC-SHWE-FS . . . . . . . . . .7A TFG-060606H . . . . . . . . . . . . .3B TFLU480 . . . . . . . . . . . . . . . . .7A RA1 . . . . . . . . . . . . . . . . . . . .7C SROLC-SHWE-FS/FS . . . . . . .7A TFG-060606I . . . . . . . . . . . . . .3E TFLU480FS . . . . . . . . . . . . . . .7A RC-1 . . . . . . . . . . . . . . . . . . .11A SROLC-SLWE-FS . . . . . . . . . .7A TFG-080604 . . . . . . . . . . . . . .3B TFPPM120-IMCRD-FS . . . . . .7A RLPPM120I-IMCRD-FS . . . . . .7A SROLC-SLWE-FS/FS . . . . . . . .7A TFG-080604H . . . . . . . . . . . . .3B TFPPM120-IMCRD-FS/FS . . . .7A RLPPM120I-IMCRD-FS/FS . . .7A SROLRC-SHWE-FS . . . . . . . . .7A TFG-080604I . . . . . . . . . . . . . .3E TFPPM240-IMCRD-FS . . . . . .7A RLPPM240I-IMCRD-FS . . . . . .7A SROLRC-SHWE-FS/FS . . . . . .7A TFG-080606 . . . . . . . . . . . . . .3B TFPPM240-IMCRD-FS/FS . . . .7A RLPPM240I-IMCRD-FS/FS . . .7A SROLRC-SLWE-FS . . . . . . . . .7A TFG-080606H . . . . . . . . . . . . .3B TFPPM480-IMCRD-FS . . . . . .7A RLPTT120IFS . . . . . . . . . . . . .7A SROLRC-SLWE-FS/FS . . . . . . .7A TFG-080606I . . . . . . . . . . . . . .3E TFPPM480-IMCRD-FS/FS . . . .7A RLPTT120LFS . . . . . . . . . . . . .7A SROLR-SHWE-FS . . . . . . . . . .7A TFG-100804 . . . . . . . . . . . . . .3B TFPPM600-IMCRD-FS . . . . . .7A 365 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 366 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX TFPPM600-IMCRD-FS/FS . . . .7A TN4X6-242012 . . . . . . . . . . . .3B TN4X6-363008 . . . . . . . . . . . .3B TSC4-101006 . . . . . . . . . . . . .3B TFPTT120FS . . . . . . . . . . . . . .7A TN4X6-242016 . . . . . . . . . . . .3B TN4X6-363010 . . . . . . . . . . . .3B TSC4-101008 . . . . . . . . . . . . .3B TFPTT240FS . . . . . . . . . . . . . .7A TN4X6-242406 . . . . . . . . . . . .3B TN4X6-363012 . . . . . . . . . . . .3B TSC4-120604 . . . . . . . . . . . . .3B TFPTT480FS . . . . . . . . . . . . . .7A TN4X6-242408 . . . . . . . . . . . .3B TN4X6-363016 . . . . . . . . . . . .3B TSC4-120605 . . . . . . . . . . . . .3B TFT-6015 . . . . . . . . . . . . . . . .11A TN4X6-242410 . . . . . . . . . . . .3B TN4X6-363020 . . . . . . . . . . . .3B TSC4-120805 . . . . . . . . . . . . .3B TFT-6020 . . . . . . . . . . . . . . . .11A TN4X6-242412 . . . . . . . . . . . .3B TN4X6-363608 . . . . . . . . . . . .3B TSC4-120806 . . . . . . . . . . . . .3B TFT-6575 . . . . . . . . . . . . . . . .11A TN4X6-242416 . . . . . . . . . . . .3B TN4X6-363612 . . . . . . . . . . . .3B TSC4-121206 . . . . . . . . . . . . .3B TGB-10025 . . . . . . . . . . . . . .11A TN4X6-243008 . . . . . . . . . . . .3B TN4X6-392907 . . . . . . . . . . . .3B TSC4-121208 . . . . . . . . . . . . .3B TGB-10050 . . . . . . . . . . . . . .11A TN4X6-251807 . . . . . . . . . . . .3B TN4X6-392907-A . . . . . . . . . . .3B TSC4-151506 . . . . . . . . . . . . .3B TGB-20025 . . . . . . . . . . . . . .11A TN4X6-251807-A . . . . . . . . . . .3B TN4X6-392907-AB . . . . . . . . .3B TSC4-151508 . . . . . . . . . . . . .3B THVT-3010 . . . . . . . . . . . . . .11A TN4X6-251807-AB . . . . . . . . .3B TN4X6-392907-ABCD . . . . . . .3B TSC4-161206 . . . . . . . . . . . . .3B THVT-3015 . . . . . . . . . . . . . .11A TN4X6-251807-ABCD . . . . . . .3B TN4X6-392907-B . . . . . . . . . . .3B TSC4-161208 . . . . . . . . . . . . .3B THVT-3020 . . . . . . . . . . . . . .11A TN4X6-251807-B . . . . . . . . . . .3B TN4X6-392907-C . . . . . . . . . . .3B TSC4-161606 . . . . . . . . . . . . .3B THVT-3075 . . . . . . . . . . . . . .11A TN4X6-251807-C . . . . . . . . . . .3B TN4X6-392907-CD . . . . . . . . .3B TSC4-161608 . . . . . . . . . . . . .3B TN4X6-122406 . . . . . . . . . . . .3B TN4X6-251807-CD . . . . . . . . .3B TN4X6-392907-D . . . . . . . . . . .3B TSC4X-050503 . . . . . . . . . . . .3B TN4X6-122408 . . . . . . . . . . . .3B TN4X6-251807-D . . . . . . . . . . .3B TN4X6-422408 . . . . . . . . . . . .3B TSC4X-060604 . . . . . . . . . . . .3B TN4X6-161206 . . . . . . . . . . . .3B TN4X6-301606 . . . . . . . . . . . .3B TN4X6-423008 . . . . . . . . . . . .3B TSC4X-070704 . . . . . . . . . . . .3B TN4X6-161208 . . . . . . . . . . . .3B TN4X6-302006 . . . . . . . . . . . .3B TN4X6-423012 . . . . . . . . . . . .3B TSC4X-080804 . . . . . . . . . . . .3B TN4X6-161210 . . . . . . . . . . . .3B TN4X6-302008 . . . . . . . . . . . .3B TN4X6-423608 . . . . . . . . . . . .3B TSC4X-101006 . . . . . . . . . . . .3B TN4X6-161606 . . . . . . . . . . . .3B TN4X6-302010 . . . . . . . . . . . .3B TN4X6-423612 . . . . . . . . . . . .3B TSC4X-101008 . . . . . . . . . . . .3B TN4X6-161608 . . . . . . . . . . . .3B TN4X6-302207 . . . . . . . . . . . .3B TN4X6-423616 . . . . . . . . . . . .3B TSC4X-120604 . . . . . . . . . . . .3B TN4X6-162006 . . . . . . . . . . . .3B TN4X6-302207-A . . . . . . . . . . .3B TN4X6-482408 . . . . . . . . . . . .3B TSC4X-120605 . . . . . . . . . . . .3B TN4X6-162008 . . . . . . . . . . . .3B TN4X6-302207-AB . . . . . . . . .3B TN4X6-483008 . . . . . . . . . . . .3B TSC4X-120805 . . . . . . . . . . . .3B TN4X6-201206 . . . . . . . . . . . .3B TN4X6-302207-ABCD . . . . . . .3B TN4X6-483010 . . . . . . . . . . . .3B TSC4X-120806 . . . . . . . . . . . .3B TN4X6-201208 . . . . . . . . . . . .3B TN4X6-302207-B . . . . . . . . . . .3B TN4X6-483608 . . . . . . . . . . . .3B TSC4X-121206 . . . . . . . . . . . .3B TN4X6-201407 . . . . . . . . . . . .3B TN4X6-302207-C . . . . . . . . . . .3B TN4X6-483610 . . . . . . . . . . . .3B TSC4X-121208 . . . . . . . . . . . .3B TN4X6-201407-A . . . . . . . . . . .3B TN4X6-302207-CD . . . . . . . . .3B TN4X6-483612 . . . . . . . . . . . .3B TSC4X-151506 . . . . . . . . . . . .3B TN4X6-201407-AB . . . . . . . . .3B TN4X6-302207-D . . . . . . . . . . .3B TN4X6-483616 . . . . . . . . . . . .3B TSC4X-151508 . . . . . . . . . . . .3B TN4X6-201407-ABCD . . . . . . .3B TN4X6-302406 . . . . . . . . . . . .3B TN4X6-483620 . . . . . . . . . . . .3B TSC4X-161206 . . . . . . . . . . . .3B TN4X6-201407-B . . . . . . . . . . .3B TN4X6-302408 . . . . . . . . . . . .3B TN4X6-483624 . . . . . . . . . . . .3B TSC4X-161208 . . . . . . . . . . . .3B TN4X6-201407-C . . . . . . . . . . .3B TN4X6-302410 . . . . . . . . . . . .3B TN4X6-603608 . . . . . . . . . . . .3B TSC4X-161606 . . . . . . . . . . . .3B TN4X6-201407-CD . . . . . . . . .3B TN4X6-302412 . . . . . . . . . . . .3B TN4X6-603610 . . . . . . . . . . . .3B TSC4X-161608 . . . . . . . . . . . .3B TN4X6-201407-D . . . . . . . . . . .3B TN4X6-302416 . . . . . . . . . . . .3B TN4X6-603612 . . . . . . . . . . . .3B TSC4X6-050503 . . . . . . . . . . .3B TN4X6-201606 . . . . . . . . . . . .3B TN4X6-302420 . . . . . . . . . . . .3B TN4X6-603616 . . . . . . . . . . . .3B TSC4X6-060604 . . . . . . . . . . .3B TN4X6-201608 . . . . . . . . . . . .3B TN4X6-303008 . . . . . . . . . . . .3B TN4X6-603620 . . . . . . . . . . . .3B TSC4X6-060604I . . . . . . . . . . .3E TN4X6-201610 . . . . . . . . . . . .3B TN4X6-303012 . . . . . . . . . . . .3B TN4X6-603624 . . . . . . . . . . . .3B TSC4X6-070704 . . . . . . . . . . .3B TN4X6-201612 . . . . . . . . . . . .3B TN4X6-303608 . . . . . . . . . . . .3B TNJ-3010 . . . . . . . . . . . . . . .11A TSC4X6-070704I . . . . . . . . . . .3E TN4X6-202006 . . . . . . . . . . . .3B TN4X6-362406 . . . . . . . . . . . .3B TNJ-3015 . . . . . . . . . . . . . . .11A TSC4X6-080804 . . . . . . . . . . .3B TN4X6-202008 . . . . . . . . . . . .3B TN4X6-362408 . . . . . . . . . . . .3B TNJ-3020 . . . . . . . . . . . . . . .11A TSC4X6-080804I . . . . . . . . . . .3E TN4X6-202010 . . . . . . . . . . . .3B TN4X6-362410 . . . . . . . . . . . .3B TNJ-3075 . . . . . . . . . . . . . . .11A TSC4X6-101006 . . . . . . . . . . .3B TN4X6-202406 . . . . . . . . . . . .3B TN4X6-362412 . . . . . . . . . . . .3B TPVC 20 . . . . . . . . . . . . . . . .11A TSC4X6-101006I . . . . . . . . . . .3E TN4X6-202408 . . . . . . . . . . . .3B TN4X6-362507 . . . . . . . . . . . .3B TPVC 66 . . . . . . . . . . . . . . . .11A TSC4X6-101008 . . . . . . . . . . .3B TN4X6-241206 . . . . . . . . . . . .3B TN4X6-362507-A . . . . . . . . . . .3B TSB 100 . . . . . . . . . . . . . . . .11A TSC4X6-101008I . . . . . . . . . . .3E TN4X6-241208 . . . . . . . . . . . .3B TN4X6-362507-AB . . . . . . . . .3B TSB 15 . . . . . . . . . . . . . . . . .11A TSC4X6-120604 . . . . . . . . . . .3B TN4X6-241210 . . . . . . . . . . . .3B TN4X6-362507-ABCD . . . . . . .3B TSB 432 . . . . . . . . . . . . . . . .11A TSC4X6-120604I . . . . . . . . . . .3E TN4X6-241606 . . . . . . . . . . . .3B TN4X6-362507-B . . . . . . . . . . .3B TSC 15 . . . . . . . . . . . . . . . . .11A TSC4X6-120605 . . . . . . . . . . .3B TN4X6-241608 . . . . . . . . . . . .3B TN4X6-362507-C . . . . . . . . . . .3B TSC4-050503 . . . . . . . . . . . . .3B TSC4X6-120605I . . . . . . . . . . .3E TN4X6-242006 . . . . . . . . . . . .3B TN4X6-362507-CD . . . . . . . . .3B TSC4-060604 . . . . . . . . . . . . .3B TSC4X6-120805 . . . . . . . . . . .3B TN4X6-242008 . . . . . . . . . . . .3B TN4X6-362507-D . . . . . . . . . . .3B TSC4-070704 . . . . . . . . . . . . .3B TSC4X6-120805I . . . . . . . . . . .3E TN4X6-242010 . . . . . . . . . . . .3B TN4X6-363006 . . . . . . . . . . . .3B TSC4-080804 . . . . . . . . . . . . .3B TSC4X6-120806 . . . . . . . . . . .3B 366 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 367 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section TSC4X6-120806I . . . . . . . . . . .3E WIF 164810 . . . . . . . . . . . . . .5B X 82 XDC . . . . . . . . . . . . . . . .5E X2FG-1B2 . . . . . . . . . . . . . . . .7A TSC4X6-121206 . . . . . . . . . . .3B WIF 202408 . . . . . . . . . . . . . .5B X 82 XDC N4 . . . . . . . . . . . . . .5E X2FG-1B3 . . . . . . . . . . . . . . . .7A TSC4X6-121206I . . . . . . . . . . .3E WIF 202412 . . . . . . . . . . . . . .5B X 8230 . . . . . . . . . . . . . . . . . .5E X2FG-1B4 . . . . . . . . . . . . . . . .7A TSC4X6-121208 . . . . . . . . . . .3B WIF 242414 . . . . . . . . . . . . . .5B X 83 . . . . . . . . . . . . . . . . . . . .5E X2FG-1F2 . . . . . . . . . . . . . . . .7A TSC4X6-121208I . . . . . . . . . . .3E WIF 243608 . . . . . . . . . . . . . .5B X 83 C . . . . . . . . . . . . . . . . . . .5E X2FG-1F3 . . . . . . . . . . . . . . . .7A TSC4X6-151506 . . . . . . . . . . .3B WIF 364808 . . . . . . . . . . . . . .5B X 83 N4 . . . . . . . . . . . . . . . . . .5E X2FG-1F4 . . . . . . . . . . . . . . . .7A TSC4X6-151506I . . . . . . . . . . .3E WJF 061105 . . . . . . . . . . . . . .5A X 83 XDC . . . . . . . . . . . . . . . .5E X2FG-1T2 . . . . . . . . . . . . . . . .7A TSC4X6-151508 . . . . . . . . . . .3B WJF 061305 . . . . . . . . . . . . . .5A X 83 XDC N4 . . . . . . . . . . . . . .5E X2FG-1T3 . . . . . . . . . . . . . . . .7A TSC4X6-151508I . . . . . . . . . . .3E WJF 071805 . . . . . . . . . . . . . .5A X 8P . . . . . . . . . . . . . . . . . . . .7B X2FG-1T4 . . . . . . . . . . . . . . . .7A TSC4X6-161206 . . . . . . . . . . .3B WJF 121806 . . . . . . . . . . . . . .5A X2CS-1 . . . . . . . . . . . . . . . . . .7A X2FG-2 . . . . . . . . . . . . . . . . . .7A TSC4X6-161206I . . . . . . . . . . .3E WJF 122005 . . . . . . . . . . . . . .5A X2CS-1B2 . . . . . . . . . . . . . . . .7A X2FG-2B2 . . . . . . . . . . . . . . . .7A TSC4X6-161208 . . . . . . . . . . .3B WJF 122406 . . . . . . . . . . . . . .5A X2CS-1B3 . . . . . . . . . . . . . . . .7A X2FG-2B3 . . . . . . . . . . . . . . . .7A TSC4X6-161208I . . . . . . . . . . .3E WJF 122408 . . . . . . . . . . . . . .5A X2CS-1B4 . . . . . . . . . . . . . . . .7A X2FG-2B4 . . . . . . . . . . . . . . . .7A TSC4X6-161606 . . . . . . . . . . .3B WJF 123006 . . . . . . . . . . . . . .5A X2CS-1F2 . . . . . . . . . . . . . . . .7A X2FG-2F2 . . . . . . . . . . . . . . . .7A TSC4X6-161606I . . . . . . . . . . .3E WJF 123208 . . . . . . . . . . . . . .5A X2CS-1F3 . . . . . . . . . . . . . . . .7A X2FG-2F3 . . . . . . . . . . . . . . . .7A TSC4X6-161608 . . . . . . . . . . .3B WJF 123608 . . . . . . . . . . . . . .5A X2CS-1F4 . . . . . . . . . . . . . . . .7A X2FG-2F4 . . . . . . . . . . . . . . . .7A TSC4X6-161608I . . . . . . . . . . .3E WSG . . . . . . . . . . . . . . . . . . . .5E X2CS-1T2 . . . . . . . . . . . . . . . .7A X2FG-2T2 . . . . . . . . . . . . . . . .7A TSIL 30 . . . . . . . . . . . . . . . . .11A WSO . . . . . . . . . . . . . . . . . . . .5E X2CS-1T3 . . . . . . . . . . . . . . . .7A X2FG-2T3 . . . . . . . . . . . . . . . .7A TVD 1205 . . . . . . . . . . . . . . .11A WTB-1 . . . . . . . . . . . . . . . . .11A X2CS-1T4 . . . . . . . . . . . . . . . .7A X2FG-2T4 . . . . . . . . . . . . . . . .7A TVD 1210 . . . . . . . . . . . . . . .11A WTB-2 . . . . . . . . . . . . . . . . .11A X2CS-2 . . . . . . . . . . . . . . . . . .7A X2FG-3 . . . . . . . . . . . . . . . . . .7A TVD 1275 . . . . . . . . . . . . . . .11A WTB-3 . . . . . . . . . . . . . . . . .11A X2CS-2B2 . . . . . . . . . . . . . . . .7A X2FG-3B2 . . . . . . . . . . . . . . . .7A TVD 4810 . . . . . . . . . . . . . . .11A X 1 . . . . . . . . . . . . . . . . . . . . .7B X2CS-2B3 . . . . . . . . . . . . . . . .7A X2FG-3B3 . . . . . . . . . . . . . . . .7A TVD 5475 . . . . . . . . . . . . . . .11A X 12 . . . . . . . . . . . . . . . . . . . .7B X2CS-2B4 . . . . . . . . . . . . . . . .7A X2FG-3B4 . . . . . . . . . . . . . . . .7A V-1212 . . . . . . . . . . . . . . . . . .1C X 12P . . . . . . . . . . . . . . . . . . .7B X2CS-2F2 . . . . . . . . . . . . . . . .7A X2FG-3F2 . . . . . . . . . . . . . . . .7A V-1612 . . . . . . . . . . . . . . . . . .1C X 15 . . . . . . . . . . . . . . . . . . . .7B X2CS-2F3 . . . . . . . . . . . . . . . .7A X2FG-3F3 . . . . . . . . . . . . . . . .7A V-1616 . . . . . . . . . . . . . . . . . .1C X 15P . . . . . . . . . . . . . . . . . . .7B X2CS-2F4 . . . . . . . . . . . . . . . .7A X2FG-3F4 . . . . . . . . . . . . . . . .7A V-2016 . . . . . . . . . . . . . . . . . .1C X 18 . . . . . . . . . . . . . . . . . . . .7B X2CS-2T2 . . . . . . . . . . . . . . . .7A X2FG-3T2 . . . . . . . . . . . . . . . .7A V-2020 . . . . . . . . . . . . . . . . . .1C X 18P . . . . . . . . . . . . . . . . . . .7B X2CS-2T3 . . . . . . . . . . . . . . . .7A X2FG-3T3 . . . . . . . . . . . . . . . .7A V-2412 . . . . . . . . . . . . . . . . . .1C X 1P . . . . . . . . . . . . . . . . . . . .7B X2CS-2T4 . . . . . . . . . . . . . . . .7A X2FG-3T4 . . . . . . . . . . . . . . . .7A V-2416 . . . . . . . . . . . . . . . . . .1C X 2 . . . . . . . . . . . . . . . . . . . . .7B X2CS-3 . . . . . . . . . . . . . . . . . .7A X2FG-4 . . . . . . . . . . . . . . . . . .7A V-2420 . . . . . . . . . . . . . . . . . .1C X 2P . . . . . . . . . . . . . . . . . . . .7B X2CS-3B2 . . . . . . . . . . . . . . . .7A X2FG-4B2 . . . . . . . . . . . . . . . .7A V-2424 . . . . . . . . . . . . . . . . . .1C X 3 . . . . . . . . . . . . . . . . . . . . .7B X2CS-3B3 . . . . . . . . . . . . . . . .7A X2FG-4B3 . . . . . . . . . . . . . . . .7A V-3020 . . . . . . . . . . . . . . . . . .1C X 3P . . . . . . . . . . . . . . . . . . . .7B X2CS-3B4 . . . . . . . . . . . . . . . .7A X2FG-4B4 . . . . . . . . . . . . . . . .7A V-3024 . . . . . . . . . . . . . . . . . .1C X 4 . . . . . . . . . . . . . . . . . . . . .7B X2CS-3F2 . . . . . . . . . . . . . . . .7A X2FG-4F2 . . . . . . . . . . . . . . . .7A V-3030 . . . . . . . . . . . . . . . . . .1C X 4P . . . . . . . . . . . . . . . . . . . .7B X2CS-3F3 . . . . . . . . . . . . . . . .7A X2FG-4F3 . . . . . . . . . . . . . . . .7A V-3624 . . . . . . . . . . . . . . . . . .1C X 5 . . . . . . . . . . . . . . . . . . . . .7B X2CS-3F4 . . . . . . . . . . . . . . . .7A X2FG-4F4 . . . . . . . . . . . . . . . .7A V-3630 . . . . . . . . . . . . . . . . . .1C X 5P . . . . . . . . . . . . . . . . . . . .7B X2CS-3T2 . . . . . . . . . . . . . . . .7A X2FG-4T2 . . . . . . . . . . . . . . . .7A V-3636 . . . . . . . . . . . . . . . . . .1C X 6 . . . . . . . . . . . . . . . . . . . . .7B X2CS-3T3 . . . . . . . . . . . . . . . .7A X2FG-4T3 . . . . . . . . . . . . . . . .7A V-4230 . . . . . . . . . . . . . . . . . .1C X 643 . . . . . . . . . . . . . . . . . . .5E X2CS-3T4 . . . . . . . . . . . . . . . .7A X2FG-4T4 . . . . . . . . . . . . . . . .7A V-4236 . . . . . . . . . . . . . . . . . .1C X 643 C . . . . . . . . . . . . . . . . . .5E X2CS-4 . . . . . . . . . . . . . . . . . .7A X2SS-1 . . . . . . . . . . . . . . . . . .7A V-4836 . . . . . . . . . . . . . . . . . .1C X 643 N4 . . . . . . . . . . . . . . . . .5E X2CS-4B2 . . . . . . . . . . . . . . . .7A X2SS-1B2 . . . . . . . . . . . . . . . .7A V-6036 . . . . . . . . . . . . . . . . . .1C X 643 XDC . . . . . . . . . . . . . . .5E X2CS-4B3 . . . . . . . . . . . . . . . .7A X2SS-1B3 . . . . . . . . . . . . . . . .7A WACS 238 . . . . . . . . . . . . . .11A X 643 XDC N4 . . . . . . . . . . . . .5E X2CS-4B4 . . . . . . . . . . . . . . . .7A X2SS-1B4 . . . . . . . . . . . . . . . .7A WACS 288 . . . . . . . . . . . . . .11A X 6P . . . . . . . . . . . . . . . . . . . .7B X2CS-4F2 . . . . . . . . . . . . . . . .7A X2SS-1F2 . . . . . . . . . . . . . . . .7A WACS 330 . . . . . . . . . . . . . .11A X 7 . . . . . . . . . . . . . . . . . . . . .7B X2CS-4F3 . . . . . . . . . . . . . . . .7A X2SS-1F3 . . . . . . . . . . . . . . . .7A WACS 338 . . . . . . . . . . . . . .11A X 7P . . . . . . . . . . . . . . . . . . . .7B X2CS-4F4 . . . . . . . . . . . . . . . .7A X2SS-1F4 . . . . . . . . . . . . . . . .7A WACS 380 . . . . . . . . . . . . . .11A X 8 . . . . . . . . . . . . . . . . . . . . .7B X2CS-4T2 . . . . . . . . . . . . . . . .7A X2SS-1T2 . . . . . . . . . . . . . . . .7A WACS 388 . . . . . . . . . . . . . .11A X 82 . . . . . . . . . . . . . . . . . . . .5E X2CS-4T3 . . . . . . . . . . . . . . . .7A X2SS-1T3 . . . . . . . . . . . . . . . .7A WACS 420 . . . . . . . . . . . . . .11A X 82 C . . . . . . . . . . . . . . . . . . .5E X2CS-4T4 . . . . . . . . . . . . . . . .7A X2SS-1T4 . . . . . . . . . . . . . . . .7A WIF 101406 . . . . . . . . . . . . . .5B X 82 N4 . . . . . . . . . . . . . . . . . .5E X2FG-1 . . . . . . . . . . . . . . . . . .7A X2SS-2 . . . . . . . . . . . . . . . . . .7A 367 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 368 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX X2SS-2B2 . . . . . . . . . . . . . . . .7A XCBA H . . . . . . . . . . . . . . . . .8B XCBB N4 110E63 . . . . . . . . . .8B XCBC N4 225JN2 . . . . . . . . . .8B X2SS-2B3 . . . . . . . . . . . . . . . .7A XCBA N4 . . . . . . . . . . . . . . . .8B XCBB N4 125E42 . . . . . . . . . .8B XCBC N4 225JN3 . . . . . . . . . .8B X2SS-2B4 . . . . . . . . . . . . . . . .7A XCBA N4 15E22 . . . . . . . . . . .8B XCBB N4 125E43 . . . . . . . . . .8B XCBC N4 250JI2 . . . . . . . . . . .8B X2SS-2F2 . . . . . . . . . . . . . . . .7A XCBA N4 15E23 . . . . . . . . . . .8B XCBB N4 125E62 . . . . . . . . . .8B XCBC N4 250JI3 . . . . . . . . . . .8B X2SS-2F3 . . . . . . . . . . . . . . . .7A XCBA N4 15E42 . . . . . . . . . . .8B XCBB N4 125E63 . . . . . . . . . .8B XCBC N4 250JN2 . . . . . . . . . .8B X2SS-2F4 . . . . . . . . . . . . . . . .7A XCBA N4 15E43 . . . . . . . . . . .8B XCBB N4 150E42 . . . . . . . . . .8B XCBC N4 250JN3 . . . . . . . . . .8B X2SS-2T2 . . . . . . . . . . . . . . . .7A XCBA N4 15E62 . . . . . . . . . . .8B XCBB N4 150E43 . . . . . . . . . .8B XCBC N4 70JI2 . . . . . . . . . . . .8B X2SS-2T3 . . . . . . . . . . . . . . . .7A XCBA N4 15E63 . . . . . . . . . . .8B XCBB N4 150E62 . . . . . . . . . .8B XCBC N4 70JI3 . . . . . . . . . . . .8B X2SS-2T4 . . . . . . . . . . . . . . . .7A XCBA N4 20E22 . . . . . . . . . . .8B XCBB N4 150E63 . . . . . . . . . .8B XCBC N4 70JN2 . . . . . . . . . . .8B X2SS-3 . . . . . . . . . . . . . . . . . .7A XCBA N4 20E23 . . . . . . . . . . .8B XCBB N4 80E22 . . . . . . . . . . .8B XCBC N4 70JN3 . . . . . . . . . . .8B X2SS-3B2 . . . . . . . . . . . . . . . .7A XCBA N4 20E42 . . . . . . . . . . .8B XCBB N4 80E23 . . . . . . . . . . .8B XCBC N4 80JI2 . . . . . . . . . . . .8B X2SS-3B3 . . . . . . . . . . . . . . . .7A XCBA N4 20E43 . . . . . . . . . . .8B XCBB N4 80E42 . . . . . . . . . . .8B XCBC N4 80JI3 . . . . . . . . . . . .8B X2SS-3B4 . . . . . . . . . . . . . . . .7A XCBA N4 20E62 . . . . . . . . . . .8B XCBB N4 80E43 . . . . . . . . . . .8B XCBC N4 80JN2 . . . . . . . . . . .8B X2SS-3F2 . . . . . . . . . . . . . . . .7A XCBA N4 20E63 . . . . . . . . . . .8B XCBB N4 80E62 . . . . . . . . . . .8B XCBC N4 80JN3 . . . . . . . . . . .8B X2SS-3F3 . . . . . . . . . . . . . . . .7A XCBA N4 30DN3 . . . . . . . . . . .8B XCBB N4 80E63 . . . . . . . . . . .8B XCBC N4 90JI2 . . . . . . . . . . . .8B X2SS-3F4 . . . . . . . . . . . . . . . .7A XCBA N4 30E22 . . . . . . . . . . .8B XCBB N4 90E22 . . . . . . . . . . .8B XCBC N4 90JI3 . . . . . . . . . . . .8B X2SS-3T2 . . . . . . . . . . . . . . . .7A XCBA N4 30E23 . . . . . . . . . . .8B XCBB N4 90E23 . . . . . . . . . . .8B XCBC N4 90JN2 . . . . . . . . . . .8B X2SS-3T3 . . . . . . . . . . . . . . . .7A XCBA N4 30E42 . . . . . . . . . . .8B XCBB N4 90E42 . . . . . . . . . . .8B XCBC N4 90JN3 . . . . . . . . . . .8B X2SS-3T4 . . . . . . . . . . . . . . . .7A XCBA N4 30E43 . . . . . . . . . . .8B XCBB N4 90E43 . . . . . . . . . . .8B XCBD H . . . . . . . . . . . . . . . . .8B X2SS-4 . . . . . . . . . . . . . . . . . .7A XCBA N4 30E62 . . . . . . . . . . .8B XCBB N4 90E62 . . . . . . . . . . .8B XCBD N4 . . . . . . . . . . . . . . . .8B X2SS-4B2 . . . . . . . . . . . . . . . .7A XCBA N4 30E63 . . . . . . . . . . .8B XCBB N4 90E63 . . . . . . . . . . .8B XCBD N4 100KI2 . . . . . . . . . .8B X2SS-4B3 . . . . . . . . . . . . . . . .7A XCBA N4 40E22 . . . . . . . . . . .8B XCBC H . . . . . . . . . . . . . . . . .8B XCBD N4 100KI3 . . . . . . . . . .8B X2SS-4B4 . . . . . . . . . . . . . . . .7A XCBA N4 40E23 . . . . . . . . . . .8B XCBC N4 . . . . . . . . . . . . . . . .8B XCBD N4 100KN2 . . . . . . . . . .8B X2SS-4F2 . . . . . . . . . . . . . . . .7A XCBA N4 40E42 . . . . . . . . . . .8B XCBC N4 100JI2 . . . . . . . . . . .8B XCBD N4 100KN3 . . . . . . . . . .8B X2SS-4F3 . . . . . . . . . . . . . . . .7A XCBA N4 40E43 . . . . . . . . . . .8B XCBC N4 100JI3 . . . . . . . . . . .8B XCBD N4 125KI2 . . . . . . . . . .8B X2SS-4F4 . . . . . . . . . . . . . . . .7A XCBA N4 40E62 . . . . . . . . . . .8B XCBC N4 100JN2 . . . . . . . . . .8B XCBD N4 125KI3 . . . . . . . . . .8B X2SS-4T2 . . . . . . . . . . . . . . . .7A XCBA N4 40E63 . . . . . . . . . . .8B XCBC N4 100JN3 . . . . . . . . . .8B XCBD N4 125KN2 . . . . . . . . . .8B X2SS-4T3 . . . . . . . . . . . . . . . .7A XCBA N4 50E22 . . . . . . . . . . .8B XCBC N4 110JI2 . . . . . . . . . . .8B XCBD N4 125KN3 . . . . . . . . . .8B X2SS-4T4 . . . . . . . . . . . . . . . .7A XCBA N4 50E23 . . . . . . . . . . .8B XCBC N4 110JI3 . . . . . . . . . . .8B XCBD N4 150KI2 . . . . . . . . . .8B XA 2 . . . . . . . . . . . . . . . . . . . .5E XCBA N4 50E42 . . . . . . . . . . .8B XCBC N4 110JN2 . . . . . . . . . .8B XCBD N4 150KI3 . . . . . . . . . .8B XA 3 . . . . . . . . . . . . . . . . . . . .5E XCBA N4 50E43 . . . . . . . . . . .8B XCBC N4 110JN3 . . . . . . . . . .8B XCBD N4 150KN2 . . . . . . . . . .8B XAF 24 . . . . . . . . . . . . . . . . .10A XCBA N4 50E62 . . . . . . . . . . .8B XCBC N4 125JI2 . . . . . . . . . . .8B XCBD N4 150KN3 . . . . . . . . . .8B XAF 6 . . . . . . . . . . . . . . . . . .10A XCBA N4 50E63 . . . . . . . . . . .8B XCBC N4 125JI3 . . . . . . . . . . .8B XCBD N4 175KI2 . . . . . . . . . .8B XAF 64 . . . . . . . . . . . . . . . . .10A XCBA N4 60DN3 . . . . . . . . . . .8B XCBC N4 125JN2 . . . . . . . . . .8B XCBD N4 175KI3 . . . . . . . . . .8B XB 1 . . . . . . . . . . . . . . . . . . . .5E XCBA N4 60E22 . . . . . . . . . . .8B XCBC N4 125JN3 . . . . . . . . . .8B XCBD N4 175KN2 . . . . . . . . . .8B XB 2 . . . . . . . . . . . . . . . . . . . .5E XCBA N4 60E23 . . . . . . . . . . .8B XCBC N4 150JI2 . . . . . . . . . . .8B XCBD N4 175KN3 . . . . . . . . . .8B XB 3 . . . . . . . . . . . . . . . . . . . .5E XCBA N4 60E42 . . . . . . . . . . .8B XCBC N4 150JI3 . . . . . . . . . . .8B XCBD N4 200KI2 . . . . . . . . . .8B XB 4 . . . . . . . . . . . . . . . . . . . .5E XCBA N4 60E43 . . . . . . . . . . .8B XCBC N4 150JN2 . . . . . . . . . .8B XCBD N4 200KI3 . . . . . . . . . .8B XBB . . . . . . . . . . . . . . . . . . . .9A XCBA N4 60E62 . . . . . . . . . . .8B XCBC N4 150JN3 . . . . . . . . . .8B XCBD N4 200KN2 . . . . . . . . . .8B XBCB 1 . . . . . . . . . . . . . . . . . .8A XCBA N4 60E63 . . . . . . . . . . .8B XCBC N4 175JI2 . . . . . . . . . . .8B XCBD N4 200KN3 . . . . . . . . . .8B XBCB 1 GF . . . . . . . . . . . . . . .8A XCBA N4 70E22 . . . . . . . . . . .8B XCBC N4 175JI3 . . . . . . . . . . .8B XCBD N4 225KI2 . . . . . . . . . .8B XBCB 2 . . . . . . . . . . . . . . . . . .8A XCBA N4 70E23 . . . . . . . . . . .8B XCBC N4 175JN2 . . . . . . . . . .8B XCBD N4 225KI3 . . . . . . . . . .8B XBCB 3 . . . . . . . . . . . . . . . . . .8A XCBA N4 70E42 . . . . . . . . . . .8B XCBC N4 175JN3 . . . . . . . . . .8B XCBD N4 225KN2 . . . . . . . . . .8B XBCC 1 SN . . . . . . . . . . . . . . .8A XCBA N4 70E43 . . . . . . . . . . .8B XCBC N4 200DN3 . . . . . . . . . .8B XCBD N4 225KN3 . . . . . . . . . .8B XBG . . . . . . . . . . . . . . . . . . . .9A XCBA N4 70E62 . . . . . . . . . . .8B XCBC N4 200JI2 . . . . . . . . . . .8B XCBE H . . . . . . . . . . . . . . . . . .8B XBPC . . . . . . . . . . . . . . . . . . .9A XCBA N4 70E63 . . . . . . . . . . .8B XCBC N4 200JI3 . . . . . . . . . . .8B XCBE N4 . . . . . . . . . . . . . . . .8B XBR . . . . . . . . . . . . . . . . . . . .9A XCBB H . . . . . . . . . . . . . . . . .8B XCBC N4 200JN2 . . . . . . . . . .8B XCBE N4 250KI2 . . . . . . . . . . .8B XBSB . . . . . . . . . . . . . . . . . . .9A XCBB N4 . . . . . . . . . . . . . . . .8B XCBC N4 200JN3 . . . . . . . . . .8B XCBE N4 250KI3 . . . . . . . . . . .8B XBSG . . . . . . . . . . . . . . . . . . .9A XCBB N4 100DN3 . . . . . . . . . .8B XCBC N4 225JI2 . . . . . . . . . . .8B XCBE N4 250KN2 . . . . . . . . . .8B XBSR . . . . . . . . . . . . . . . . . . .9A XCBB N4 100E22 . . . . . . . . . .8B XCBC N4 225JI3 . . . . . . . . . . .8B XCBE N4 250KN3 . . . . . . . . . .8B 368 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 369 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section XCBE N4 250LI2 . . . . . . . . . . .8B XCBSAQ N4 M6003 . . . . . . . .8C XCE 061105 N4 . . . . . . . . . . .5A XCE 162408 N4 . . . . . . . . . . .5A XCBE N4 250LI3 . . . . . . . . . . .8B XCBSAQ N4 M6007 . . . . . . . .8C XCE 061204 N4 . . . . . . . . . . .5A XCE 162410 N4 . . . . . . . . . . .5A XCBE N4 300KI2 . . . . . . . . . . .8B XCBSAQ N4 M6015 . . . . . . . .8C XCE 061206 N4 . . . . . . . . . . .5A XCE 162806 N4 . . . . . . . . . . .5A XCBE N4 300KI3 . . . . . . . . . . .8B XCBSAQ N4 M6130 . . . . . . . .8C XCE 061305 N4 . . . . . . . . . . .5A XCE 163406 N4 . . . . . . . . . . .5A XCBE N4 300KN2 . . . . . . . . . .8B XCBSBQ H . . . . . . . . . . . . . . .8C XCE 071004 N4 . . . . . . . . . . .5A XCE 163010 N4 . . . . . . . . . . .5A XCBE N4 300KN3 . . . . . . . . . .8B XCBSBQ N4 . . . . . . . . . . . . . .8C XCE 071006 N4 . . . . . . . . . . .5A XCE 164610 N4 . . . . . . . . . . .5A XCBE N4 300LI2 . . . . . . . . . . .8B XCBSBQ N4 22100 . . . . . . . . .8C XCE 071805 N4 . . . . . . . . . . .5A XCE 181804 N4 . . . . . . . . . . .5A XCBE N4 300LI3 . . . . . . . . . . .8B XCBSBQ N4 22100 . . . . . . . . .8C XCE 080804 N4 . . . . . . . . . . .5A XCE 181806 N4 . . . . . . . . . . .5A XCBE N4 350KI2 . . . . . . . . . . .8B XCBSBQ N4 2270 . . . . . . . . . .8C XCE 080806 N4 . . . . . . . . . . .5A XCE 181808 N4 . . . . . . . . . . .5A XCBE N4 350KI3 . . . . . . . . . . .8B XCBSBQ N4 2270 . . . . . . . . . .8C XCE 080808 N4 . . . . . . . . . . .5A XCE 182406 N4 . . . . . . . . . . .5A XCBE N4 350KN2 . . . . . . . . . .8B XCBSBQ N4 4270 . . . . . . . . . .8C XCE 081004 N4 . . . . . . . . . . .5A XCE 182408 N4 . . . . . . . . . . .5A XCBE N4 350KN3 . . . . . . . . . .8B XCBSBQ N4 4270 . . . . . . . . . .8C XCE 081006 N4 . . . . . . . . . . .5A XCE 182410 N4 . . . . . . . . . . .5A XCBE N4 350LI2 . . . . . . . . . . .8B XCBSBQ N4 6250 . . . . . . . . . .8C XCE 081008 N4 . . . . . . . . . . .5A XCE 183008 N4 . . . . . . . . . . .5A XCBE N4 350LI3 . . . . . . . . . . .8B XCBSBQ N4 6250 . . . . . . . . . .8C XCE 081204 N4 . . . . . . . . . . .5A XCE 183608 N4 . . . . . . . . . . .5A XCBE N4 400KI2 . . . . . . . . . . .8B XCBSBQ N4 M6250 . . . . . . . .8C XCE 081206 N4 . . . . . . . . . . .5A XCE 183610 N4 . . . . . . . . . . .5A XCBE N4 400KI3 . . . . . . . . . . .8B XCBSBQ N4 M6250 . . . . . . . .8C XCE 081208 N4 . . . . . . . . . . .5A XCE 203606 N4 . . . . . . . . . . .5A XCBE N4 400KN2 . . . . . . . . . .8B XCBSLQ H . . . . . . . . . . . . . . .8C XCE 091105 N4 . . . . . . . . . . .5A XCE 203612 N4 . . . . . . . . . . .5A XCBE N4 400KN3 . . . . . . . . . .8B XCBSLQ N4 . . . . . . . . . . . . . .8C XCE 101004 N4 . . . . . . . . . . .5A XCE 204806 N4 . . . . . . . . . . .5A XCBE N4 400LI2 . . . . . . . . . . .8B XCBSLQ N4 23100 . . . . . . . . .8C XCE 101006 N4 . . . . . . . . . . .5A XCE 204812 N4 . . . . . . . . . . .5A XCBE N4 400LI3 . . . . . . . . . . .8B XCBSLQ N4 23125 . . . . . . . . .8C XCE 101008 N4 . . . . . . . . . . .5A XCE 242408 N4 . . . . . . . . . . .5A XCBF H . . . . . . . . . . . . . . . . . .8B XCBSLQ N4 43100 . . . . . . . . .8C XCE 101206 N4 . . . . . . . . . . .5A XCE 242410 N4 . . . . . . . . . . .5A XCBF N4 . . . . . . . . . . . . . . . .8B XCBSLQ N4 4370 . . . . . . . . . .8C XCE 101404 N4 . . . . . . . . . . .5A XCE 243008 N4 . . . . . . . . . . .5A XCBF N4 400MI2 . . . . . . . . . .8B XCBSLQ N4 63100 . . . . . . . . .8C XCE 101406 N4 . . . . . . . . . . .5A XCE 243608 N4 . . . . . . . . . . .5A XCBF N4 400MI3 . . . . . . . . . .8B XCBSLQ N4 6370 . . . . . . . . . .8C XCE 101408 N4 . . . . . . . . . . .5A XCE 243610 N4 . . . . . . . . . . .5A XCBF N4 500LI2 . . . . . . . . . . .8B XCBSLQ N4 M63100 . . . . . . .8C XCE 121204 N4 . . . . . . . . . . .5A XCE 243612 N4 . . . . . . . . . . .5A XCBF N4 500LI3 . . . . . . . . . . .8B XCBSMQ H . . . . . . . . . . . . . . .8C XCE 121206 N4 . . . . . . . . . . .5A XCE 323612 N4 . . . . . . . . . . .5A XCBF N4 500MI2 . . . . . . . . . .8B XCBSMQ N4 . . . . . . . . . . . . .8C XCE 121208 N4 . . . . . . . . . . .5A XCE/XJF 041604 . . . . . . . . . . .5A XCBF N4 500MI3 . . . . . . . . . .8B XCBSMQ N4 24175 . . . . . . . .8C XCE 121804 N4 . . . . . . . . . . .5A XCE/XJF 060804 . . . . . . . . . . .5A XCBF N4 600LI2 . . . . . . . . . . .8B XCBSMQ N4 24200 . . . . . . . .8C XCE 121806 N4 . . . . . . . . . . .5A XCE/XJF 060805 . . . . . . . . . . .5A XCBF N4 600LI3 . . . . . . . . . . .8B XCBSMQ N4 44175 . . . . . . . .8C XCE 121808 N4 . . . . . . . . . . .5A XCE/XJF 060806 . . . . . . . . . . .5A XCBF N4 600MI2 . . . . . . . . . .8B XCBSMQ N4 44200 . . . . . . . .8C XCE 122005 N4 . . . . . . . . . . .5A XCE/XJF 061105 . . . . . . . . . . .5A XCBF N4 600MI3 . . . . . . . . . .8B XCBSMQ N4 64125 . . . . . . . .8C XCE 122404 N4 . . . . . . . . . . .5A XCE/XJF 061204 . . . . . . . . . . .5A XCBF N4 700MI2 . . . . . . . . . .8B XCBSMQ N4 64150 . . . . . . . .8C XCE 122406 N4 . . . . . . . . . . .5A XCE/XJF 061206 . . . . . . . . . . .5A XCBF N4 700MI3 . . . . . . . . . .8B XCBSMQ N4 64175 . . . . . . . .8C XCE 122408 N4 . . . . . . . . . . .5A XCE/XJF 061305 . . . . . . . . . . .5A XCBF N4 800MI2 . . . . . . . . . .8B XCBSN H . . . . . . . . . . . . . . . .8C XCE 122410 N4 . . . . . . . . . . .5A XCE/XJF 071004 . . . . . . . . . . .5A XCBF N4 800MI3 . . . . . . . . . .8B XCBSN N4 . . . . . . . . . . . . . . .8C XCE 123006 N4 . . . . . . . . . . .5A XCE/XJF 071006 . . . . . . . . . . .5A XCBG H . . . . . . . . . . . . . . . . .8B XCBSN N4 25225 . . . . . . . . . .8C XCE 123604 N4 . . . . . . . . . . .5A XCE/XJF 071805 . . . . . . . . . . .5A XCBG N4 . . . . . . . . . . . . . . . .8B XCBSN N4 25300 . . . . . . . . . .8C XCE 123606 N4 . . . . . . . . . . .5A XCE/XJF 080804 . . . . . . . . . . .5A XCBH 1 GF . . . . . . . . . . . . . . .8A XCBSN N4 25400 . . . . . . . . . .8C XCE 123608 N4 . . . . . . . . . . .5A XCE/XJF 080806 . . . . . . . . . . .5A XCBSAQ H . . . . . . . . . . . . . . .8C XCBSN N4 45225 . . . . . . . . . .8C XCE 124608 N4 . . . . . . . . . . .5A XCE/XJF 080808 . . . . . . . . . . .5A XCBSAQ N4 2015 . . . . . . . . . .8C XCBSN N4 45300 . . . . . . . . . .8C XCE 141404 N4 . . . . . . . . . . .5A XCE/XJF 081004 . . . . . . . . . . .5A XCBSAQ N4 2020 . . . . . . . . . .8C XCBSN N4 45400 . . . . . . . . . .8C XCE 141406 N4 . . . . . . . . . . .5A XCE/XJF 081006 . . . . . . . . . . .5A XCBSAQ N4 2130 . . . . . . . . . .8C XCBSN N4 65200 . . . . . . . . . .8C XCE 141408 N4 . . . . . . . . . . .5A XCE/XJF 081008 . . . . . . . . . . .5A XCBSAQ N4 2150 . . . . . . . . . .8C XCBSN N4 65225 . . . . . . . . . .8C XCE 142210 N4 . . . . . . . . . . .5A XCE/XJF 081204 . . . . . . . . . . .5A XCBSAQ N4 4015 . . . . . . . . . .8C XCBSN N4 65400 . . . . . . . . . .8C XCE 142213 N4 . . . . . . . . . . .5A XCE/XJF 081206 . . . . . . . . . . .5A XCBSAQ N4 4020 . . . . . . . . . .8C XCBSN N4 M65400 . . . . . . . .8C XCE 142806 N4 . . . . . . . . . . .5A XCE/XJF 081208 . . . . . . . . . . .5A XCBSAQ N4 4130 . . . . . . . . . .8C XCE 041604 N4 . . . . . . . . . . .5A XCE 161604 N4 . . . . . . . . . . .5A XCE/XJF 091105 . . . . . . . . . . .5A XCBSAQ N4 6015 . . . . . . . . . .8C XCE 060804 N4 . . . . . . . . . . .5A XCE 161606 N4 . . . . . . . . . . .5A XCE/XJF 101004 . . . . . . . . . . .5A XCBSAQ N4 6020 . . . . . . . . . .8C XCE 060805 N4 . . . . . . . . . . .5A XCE 161608 N4 . . . . . . . . . . .5A XCE/XJF 101006 . . . . . . . . . . .5A XCBSAQ N4 6130 . . . . . . . . . .8C XCE 060806 N4 . . . . . . . . . . .5A XCE 162406 N4 . . . . . . . . . . .5A XCE/XJF 101008 . . . . . . . . . . .5A 369 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 370 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX XCE/XJF 101404 . . . . . . . . . . .5A XCE/XJF 323612 . . . . . . . . . . .5A XCEX 142806 . . . . . . . . . . . . .5A XCIAD12 . . . . . . . . . . . . . . . . .8D XCE/XJF 101406 . . . . . . . . . . .5A XCEX 041604 . . . . . . . . . . . . .5A XCEX 161604 . . . . . . . . . . . . .5A XCIAD18 . . . . . . . . . . . . . . . . .8D XCE/XJF 101408 . . . . . . . . . . .5A XCEX 060804 . . . . . . . . . . . . .5A XCEX 161606 . . . . . . . . . . . . .5A XCIAD25 . . . . . . . . . . . . . . . . .8D XCE/XJF 101410 . . . . . . . . . . .5A XCEX 060805 . . . . . . . . . . . . .5A XCEX 161608 . . . . . . . . . . . . .5A XCIAD32 . . . . . . . . . . . . . . . . .8D XCE/XJF 121204 . . . . . . . . . . .5A XCEX 060806 . . . . . . . . . . . . .5A XCEX 162406 . . . . . . . . . . . . .5A XCIAD37 . . . . . . . . . . . . . . . . .8D XCE/XJF 121206 . . . . . . . . . . .5A XCEX 061105 . . . . . . . . . . . . .5A XCEX 162408 . . . . . . . . . . . . .5A XCIAD40 . . . . . . . . . . . . . . . . .8D XCE/XJF 121208 . . . . . . . . . . .5A XCEX 061204 . . . . . . . . . . . . .5A XCEX 162410 . . . . . . . . . . . . .5A XCIAD50 . . . . . . . . . . . . . . . . .8D XCE/XJF 121804 . . . . . . . . . . .5A XCEX 061206 . . . . . . . . . . . . .5A XCEX 162806 . . . . . . . . . . . . .5A XCIAD65 . . . . . . . . . . . . . . . . .8D XCE/XJF 121806 . . . . . . . . . . .5A XCEX 061305 . . . . . . . . . . . . .5A XCEX 163010 . . . . . . . . . . . . .5A XCIAD9 . . . . . . . . . . . . . . . . . .8D XCE/XJF 121808 . . . . . . . . . . .5A XCEX 071004 . . . . . . . . . . . . .5A XCEX 163406 . . . . . . . . . . . . .5A XCIAH10 . . . . . . . . . . . . . . . . .8D XCE/XJF 122005 . . . . . . . . . . .5A XCEX 071006 . . . . . . . . . . . . .5A XCEX 164610 . . . . . . . . . . . . .5A XCIAH12 . . . . . . . . . . . . . . . . .8D XCE/XJF 122404 . . . . . . . . . . .5A XCEX 071805 . . . . . . . . . . . . .5A XCEX 181804 . . . . . . . . . . . . .5A XCIAH18 . . . . . . . . . . . . . . . . .8D XCE/XJF 122406 . . . . . . . . . . .5A XCEX 080804 . . . . . . . . . . . . .5A XCEX 181806 . . . . . . . . . . . . .5A XCIAH25 . . . . . . . . . . . . . . . . .8D XCE/XJF 122408 . . . . . . . . . . .5A XCEX 080806 . . . . . . . . . . . . .5A XCEX 181808 . . . . . . . . . . . . .5A XCIAH32 . . . . . . . . . . . . . . . . .8D XCE/XJF 122410 . . . . . . . . . . .5A XCEX 080808 . . . . . . . . . . . . .5A XCEX 182406 . . . . . . . . . . . . .5A XCIAH37 . . . . . . . . . . . . . . . . .8D XCE/XJF 123006 . . . . . . . . . . .5A XCEX 081004 . . . . . . . . . . . . .5A XCEX 182408 . . . . . . . . . . . . .5A XCIAH44 . . . . . . . . . . . . . . . . .8D XCE/XJF 123604 . . . . . . . . . . .5A XCEX 081006 . . . . . . . . . . . . .5A XCEX 182410 . . . . . . . . . . . . .5A XCIAH60 . . . . . . . . . . . . . . . . .8D XCE/XJF 123606 . . . . . . . . . . .5A XCEX 081008 . . . . . . . . . . . . .5A XCEX 183008 . . . . . . . . . . . . .5A XCIAH73 . . . . . . . . . . . . . . . . .8D XCE/XJF 123608 . . . . . . . . . . .5A XCEX 081204 . . . . . . . . . . . . .5A XCEX 183608 . . . . . . . . . . . . .5A XCIAS12 . . . . . . . . . . . . . . . . .8D XCE/XJF 124608 . . . . . . . . . . .5A XCEX 081206 . . . . . . . . . . . . .5A XCEX 183610 . . . . . . . . . . . . .5A XCIAS17 . . . . . . . . . . . . . . . . .8D XCE/XJF 141404 . . . . . . . . . . .5A XCEX 081208 . . . . . . . . . . . . .5A XCEX 203606 . . . . . . . . . . . . .5A XCIAS25 . . . . . . . . . . . . . . . . .8D XCE/XJF 141406 . . . . . . . . . . .5A XCEX 091105 . . . . . . . . . . . . .5A XCEX 203612 . . . . . . . . . . . . .5A XCIAS28 . . . . . . . . . . . . . . . . .8D XCE/XJF 141408 . . . . . . . . . . .5A XCEX 101004 . . . . . . . . . . . . .5A XCEX 204806 . . . . . . . . . . . . .5A XCIAS32 . . . . . . . . . . . . . . . . .8D XCE/XJF 142210 . . . . . . . . . . .5A XCEX 101006 . . . . . . . . . . . . .5A XCEX 242408 . . . . . . . . . . . . .5A XCIAS40 . . . . . . . . . . . . . . . . .8D XCE/XJF 142213 . . . . . . . . . . .5A XCEX 101008 . . . . . . . . . . . . .5A XCEX 242410 . . . . . . . . . . . . .5A XCIAS50 . . . . . . . . . . . . . . . . .8D XCE/XJF 142806 . . . . . . . . . . .5A XCEX 101404 . . . . . . . . . . . . .5A XCEX 243008 . . . . . . . . . . . . .5A XCIAS9 . . . . . . . . . . . . . . . . . .8D XCE/XJF 161604 . . . . . . . . . . .5A XCEX 101406 . . . . . . . . . . . . .5A XCEX 243608 . . . . . . . . . . . . .5A XCIBB110 . . . . . . . . . . . . . . . .8D XCE/XJF 161606 . . . . . . . . . . .5A XCEX 101408 . . . . . . . . . . . . .5A XCEX 243610 . . . . . . . . . . . . .5A XCIBB80 . . . . . . . . . . . . . . . . .8D XCE/XJF 161608 . . . . . . . . . . .5A XCEX 101410 . . . . . . . . . . . . .5A XCEX 243612 . . . . . . . . . . . . .5A XCIBD80 . . . . . . . . . . . . . . . . .8D XCE/XJF 162406 . . . . . . . . . . .5A XCEX 121204 . . . . . . . . . . . . .5A XCEX 323612 . . . . . . . . . . . . .5A XCIBS65 . . . . . . . . . . . . . . . . .8D XCE/XJF 162408 . . . . . . . . . . .5A XCEX 121206 . . . . . . . . . . . . .5A XCF 1 . . . . . . . . . . . . . . . . . . .9A XCIBS80 . . . . . . . . . . . . . . . . .8D XCE/XJF 162410 . . . . . . . . . . .5A XCEX 121208 . . . . . . . . . . . . .5A XCF 1 N4 . . . . . . . . . . . . . . . .9A XCIBS95 . . . . . . . . . . . . . . . . .8D XCE/XJF 163010 . . . . . . . . . . .5A XCEX 121804 . . . . . . . . . . . . .5A XCF 2 . . . . . . . . . . . . . . . . . . .9A XCMRSG H . . . . . . . . . . . . . . .8C XCE/XJF 164610 . . . . . . . . . . .5A XCEX 121806 . . . . . . . . . . . . .5A XCF 2 N4 . . . . . . . . . . . . . . . .9A XCMRSG N4 . . . . . . . . . . . . .8C XCE/XJF 181804 . . . . . . . . . . .5A XCEX 121808 . . . . . . . . . . . . .5A XCF 3 . . . . . . . . . . . . . . . . . . .9A XCMRSG N4 2015 . . . . . . . . .8C XCE/XJF 181806 . . . . . . . . . . .5A XCEX 122005 . . . . . . . . . . . . .5A XCF 3 N4 . . . . . . . . . . . . . . . .9A XCMRSG N4 2020 . . . . . . . . .8C XCE/XJF 181808 . . . . . . . . . . .5A XCEX 122404 . . . . . . . . . . . . .5A XCF 4 . . . . . . . . . . . . . . . . . . .9A XCMRSG N4 2130 . . . . . . . . .8C XCE/XJF 182406 . . . . . . . . . . .5A XCEX 122406 . . . . . . . . . . . . .5A XCF 4 N4 . . . . . . . . . . . . . . . .9A XCMRSG N4 2150 . . . . . . . . .8C XCE/XJF 182408 . . . . . . . . . . .5A XCEX 122408 . . . . . . . . . . . . .5A XCF 5 . . . . . . . . . . . . . . . . . . .9A XCMRSG N4 4015 . . . . . . . . .8C XCE/XJF 182410 . . . . . . . . . . .5A XCEX 122410 . . . . . . . . . . . . .5A XCF 5 N4 . . . . . . . . . . . . . . . .9A XCMRSG N4 4020 . . . . . . . . .8C XCE/XJF 183008 . . . . . . . . . . .5A XCEX 123006 . . . . . . . . . . . . .5A XCFT . . . . . . . . . . . . . . . . . . . .9A XCMRSG N4 4130 . . . . . . . . .8C XCE/XJF 183608 . . . . . . . . . . .5A XCEX 123604 . . . . . . . . . . . . .5A XCIAA11 . . . . . . . . . . . . . . . . .8D XCMRSG N4 6015 . . . . . . . . .8C XCE/XJF 183610 . . . . . . . . . . .5A XCEX 123606 . . . . . . . . . . . . .5A XCIAA17 . . . . . . . . . . . . . . . . .8D XCMRSG N4 6020 . . . . . . . . .8C XCE/XJF 203612 . . . . . . . . . . .5A XCEX 123608 . . . . . . . . . . . . .5A XCIAA25 . . . . . . . . . . . . . . . . .8D XCMRSG N4 6130 . . . . . . . . .8C XCE/XJF 204812 . . . . . . . . . . .5A XCEX 124608 . . . . . . . . . . . . .5A XCIAA28 . . . . . . . . . . . . . . . . .8D XCMRSG N4 M6003 . . . . . . . .8C XCE/XJF 242408 . . . . . . . . . . .5A XCEX 141404 . . . . . . . . . . . . .5A XCIAA32 . . . . . . . . . . . . . . . . .8D XCMRSG N4 M6007 . . . . . . . .8C XCE/XJF 242410 . . . . . . . . . . .5A XCEX 141406 . . . . . . . . . . . . .5A XCIAA41 . . . . . . . . . . . . . . . . .8D XCMRSG N4 M6015 . . . . . . . .8C XCE/XJF 243008 . . . . . . . . . . .5A XCEX 141408 . . . . . . . . . . . . .5A XCIAA54 . . . . . . . . . . . . . . . . .8D XCMRSG N4 M6130 . . . . . . . .8C XCE/XJF 243608 . . . . . . . . . . .5A XCEX 142210 . . . . . . . . . . . . .5A XCIAA65 . . . . . . . . . . . . . . . . .8D XCMRSK H . . . . . . . . . . . . . . .8C XCE/XJF 243612 . . . . . . . . . . .5A XCEX 142213 . . . . . . . . . . . . .5A XCIAA9 . . . . . . . . . . . . . . . . . .8D XCMRSK N4 . . . . . . . . . . . . .8C 370 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 371 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section XCMRSK N4 22100 . . . . . . . . .8C XDHLDGCX-6T . . . . . . . . . . . .4A XFC 24 . . . . . . . . . . . . . . . . .10A XFCU 221 . . . . . . . . . . . . . . .10A XCMRSK N4 2270 . . . . . . . . .8C XDHLDGCX-8T . . . . . . . . . . . .4A XFC 26 . . . . . . . . . . . . . . . . .10A XFCU 224 . . . . . . . . . . . . . . .10A XCMRSK N4 4270 . . . . . . . . .8C XDHLFCX . . . . . . . . . . . . . . . .4A XFC 28 . . . . . . . . . . . . . . . . .10A XFCU 227 . . . . . . . . . . . . . . .10A XCMRSK N4 6270 . . . . . . . . .8C XDHLFCX-10T . . . . . . . . . . . . .4A XFC 310 . . . . . . . . . . . . . . . .10A XFCU 230 . . . . . . . . . . . . . . .10A XCMRSK N4 M6250 . . . . . . . .8C XDHLFCX-12T . . . . . . . . . . . . .4A XFC 312 . . . . . . . . . . . . . . . .10A XFCU 233 . . . . . . . . . . . . . . .10A XCMRSP H . . . . . . . . . . . . . . .8C XDHLFCX-2T . . . . . . . . . . . . . .4A XFC 315 . . . . . . . . . . . . . . . .10A XFCU 236 . . . . . . . . . . . . . . .10A XCMRSP N4 . . . . . . . . . . . . .8C XDHLFCX-4T . . . . . . . . . . . . . .4A XFC 318 . . . . . . . . . . . . . . . .10A XFCU 24 . . . . . . . . . . . . . . . .10A XCMRSP N4 23100 . . . . . . . . .8C XDHLFCX-6T . . . . . . . . . . . . . .4A XFC 321 . . . . . . . . . . . . . . . .10A XFCU 26 . . . . . . . . . . . . . . . .10A XCMRSP N4 23125 . . . . . . . . .8C XDHLFCX-8T . . . . . . . . . . . . . .4A XFC 324 . . . . . . . . . . . . . . . .10A XFCU 28 . . . . . . . . . . . . . . . .10A XCMRSP N4 43100 . . . . . . . . .8C XDHLFGCX . . . . . . . . . . . . . . .4A XFC 327 . . . . . . . . . . . . . . . .10A XFCU 310 . . . . . . . . . . . . . . .10A XCMRSP N4 43125 . . . . . . . . .8C XDHLFGCX-10T . . . . . . . . . . .4A XFC 330 . . . . . . . . . . . . . . . .10A XFCU 312 . . . . . . . . . . . . . . .10A XCMRSP N4 63100 . . . . . . . . .8C XDHLFGCX-12T . . . . . . . . . . .4A XFC 333 . . . . . . . . . . . . . . . .10A XFCU 315 . . . . . . . . . . . . . . .10A XCMRSP N4 M63100 . . . . . . .8C XDHLFGCX-2T . . . . . . . . . . . .4A XFC 336 . . . . . . . . . . . . . . . .10A XFCU 318 . . . . . . . . . . . . . . .10A XCMRSP N4 M64150 . . . . . . .8C XDHLFGCX-4T . . . . . . . . . . . .4A XFC 34 . . . . . . . . . . . . . . . . .10A XFCU 321 . . . . . . . . . . . . . . .10A XCS 1 . . . . . . . . . . . . . . . . . . .9A XDHLFGCX-6T . . . . . . . . . . . .4A XFC 36 . . . . . . . . . . . . . . . . .10A XFCU 324 . . . . . . . . . . . . . . .10A XCS 2 . . . . . . . . . . . . . . . . . . .9A XDHLFGCX-8T . . . . . . . . . . . .4A XFC 38 . . . . . . . . . . . . . . . . .10A XFCU 327 . . . . . . . . . . . . . . .10A XCS 2H . . . . . . . . . . . . . . . . . .9A XDHMDCX . . . . . . . . . . . . . . .4A XFC 410 . . . . . . . . . . . . . . . .10A XFCU 330 . . . . . . . . . . . . . . .10A XCS 3 . . . . . . . . . . . . . . . . . . .9A XDHMDCX-2T . . . . . . . . . . . . .4A XFC 412 . . . . . . . . . . . . . . . .10A XFCU 333 . . . . . . . . . . . . . . .10A XCS 4 . . . . . . . . . . . . . . . . . . .9A XDHMDCX-4T . . . . . . . . . . . . .4A XFC 415 . . . . . . . . . . . . . . . .10A XFCU 336 . . . . . . . . . . . . . . .10A XCS 5 . . . . . . . . . . . . . . . . . . .9A XDHMDCX-6T . . . . . . . . . . . . .4A XFC 418 . . . . . . . . . . . . . . . .10A XFCU 34 . . . . . . . . . . . . . . . .10A XCWL-GH . . . . . . . . . . . . . . . .9A XDHMDCX-8T . . . . . . . . . . . . .4A XFC 421 . . . . . . . . . . . . . . . .10A XFCU 36 . . . . . . . . . . . . . . . .10A XCWL-GH . . . . . . . . . . . . . . . .9A XDHMDGCX . . . . . . . . . . . . . .4A XFC 424 . . . . . . . . . . . . . . . .10A XFCU 38 . . . . . . . . . . . . . . . .10A XDB 2 . . . . . . . . . . . . . . . . . .10A XDHMDGCX-2T . . . . . . . . . . .4A XFC 427 . . . . . . . . . . . . . . . .10A XFCU 410 . . . . . . . . . . . . . . .10A XDBH 2 . . . . . . . . . . . . . . . . .10A XDHMDGCX-4T . . . . . . . . . . .4A XFC 430 . . . . . . . . . . . . . . . .10A XFCU 412 . . . . . . . . . . . . . . .10A XDC . . . . . . . . . . . . . . . . . . .10A XDHMDGCX-6T . . . . . . . . . . .4A XFC 433 . . . . . . . . . . . . . . . .10A XFCU 415 . . . . . . . . . . . . . . .10A XDF . . . . . . . . . . . . . . . . . . . .4B XDHMDGCX-8T . . . . . . . . . . .4A XFC 436 . . . . . . . . . . . . . . . .10A XFCU 418 . . . . . . . . . . . . . . .10A XDHDCX . . . . . . . . . . . . . . . . .4A XDHMFCX . . . . . . . . . . . . . . .4A XFC 46 . . . . . . . . . . . . . . . . .10A XFCU 421 . . . . . . . . . . . . . . .10A XDHDCX-2T . . . . . . . . . . . . . .4A XDHMFCX-2T . . . . . . . . . . . . .4A XFC 48 . . . . . . . . . . . . . . . . .10A XFCU 424 . . . . . . . . . . . . . . .10A XDHDCX-4T . . . . . . . . . . . . . .4A XDHMFCX-4T . . . . . . . . . . . . .4A XFC 512 . . . . . . . . . . . . . . . .10A XFCU 427 . . . . . . . . . . . . . . .10A XDHDGCX . . . . . . . . . . . . . . .4A XDHMFCX-6T . . . . . . . . . . . . .4A XFC 515 . . . . . . . . . . . . . . . .10A XFCU 430 . . . . . . . . . . . . . . .10A XDHDGCX-2T . . . . . . . . . . . . .4A XDHMFCX-8T . . . . . . . . . . . . .4A XFC 518 . . . . . . . . . . . . . . . .10A XFCU 433 . . . . . . . . . . . . . . .10A XDHDGCX-4T . . . . . . . . . . . . .4A XDHMFGCX . . . . . . . . . . . . . .4A XFC 521 . . . . . . . . . . . . . . . .10A XFCU 436 . . . . . . . . . . . . . . .10A XDHFCX . . . . . . . . . . . . . . . . .4A XDHMFGCX-2T . . . . . . . . . . . .4A XFC 524 . . . . . . . . . . . . . . . .10A XFCU 46 . . . . . . . . . . . . . . . .10A XDHFCX-2T . . . . . . . . . . . . . . .4A XDHMFGCX-4T . . . . . . . . . . . .4A XFC 527 . . . . . . . . . . . . . . . .10A XFCU 48 . . . . . . . . . . . . . . . .10A XDHFCX-4T . . . . . . . . . . . . . . .4A XDHMFGCX-6T . . . . . . . . . . . .4A XFC 530 . . . . . . . . . . . . . . . .10A XFSA2A1 . . . . . . . . . . . . . . . .7C XDHFGCX . . . . . . . . . . . . . . . .4A XDHMFGCX-8T . . . . . . . . . . . .4A XFC 533 . . . . . . . . . . . . . . . .10A XFSA2A2 . . . . . . . . . . . . . . . .7C XDHFGCX-2T . . . . . . . . . . . . .4A XDIAA17 . . . . . . . . . . . . . . . . .8D XFC 536 . . . . . . . . . . . . . . . .10A XFSA2A3 . . . . . . . . . . . . . . . .7C XDHFGCX-4T . . . . . . . . . . . . .4A XFA2 . . . . . . . . . . . . . . . . . . .10A XFC 612 . . . . . . . . . . . . . . . .10A XFSA2A4 . . . . . . . . . . . . . . . .7C XDHLDCX . . . . . . . . . . . . . . . .4A XFA-2 . . . . . . . . . . . . . . . . . .10A XFC 615 . . . . . . . . . . . . . . . .10A XFSA2A5 . . . . . . . . . . . . . . . .7C XDHLDCX-10T . . . . . . . . . . . .4A XFAX2 . . . . . . . . . . . . . . . . . .10A XFC 618 . . . . . . . . . . . . . . . .10A XFSA2AB1 . . . . . . . . . . . . . . .7C XDHLDCX-12T . . . . . . . . . . . .4A XFC 210 . . . . . . . . . . . . . . . .10A XFC 621 . . . . . . . . . . . . . . . .10A XFSA2AB2 . . . . . . . . . . . . . . .7C XDHLDCX-2T . . . . . . . . . . . . .4A XFC 212 . . . . . . . . . . . . . . . .10A XFC 624 . . . . . . . . . . . . . . . .10A XFSA2AB3 . . . . . . . . . . . . . . .7C XDHLDCX-4T . . . . . . . . . . . . .4A XFC 215 . . . . . . . . . . . . . . . .10A XFC 627 . . . . . . . . . . . . . . . .10A XFSA2AB4 . . . . . . . . . . . . . . .7C XDHLDCX-6T . . . . . . . . . . . . .4A XFC 218 . . . . . . . . . . . . . . . .10A XFC 630 . . . . . . . . . . . . . . . .10A XFSA2AB5 . . . . . . . . . . . . . . .7C XDHLDCX-8T . . . . . . . . . . . . .4A XFC 221 . . . . . . . . . . . . . . . .10A XFC 633 . . . . . . . . . . . . . . . .10A XFSA2ABC1 . . . . . . . . . . . . . .7C XDHLDGCX . . . . . . . . . . . . . .4A XFC 224 . . . . . . . . . . . . . . . .10A XFC 636 . . . . . . . . . . . . . . . .10A XFSA2ABC2 . . . . . . . . . . . . . .7C XDHLDGCX-10T . . . . . . . . . . .4A XFC 227 . . . . . . . . . . . . . . . .10A XFCU 210 . . . . . . . . . . . . . . .10A XFSA2ABC3 . . . . . . . . . . . . . .7C XDHLDGCX-12T . . . . . . . . . . .4A XFC 230 . . . . . . . . . . . . . . . .10A XFCU 212 . . . . . . . . . . . . . . .10A XFSA2ABC4 . . . . . . . . . . . . . .7C XDHLDGCX-2T . . . . . . . . . . . .4A XFC 233 . . . . . . . . . . . . . . . .10A XFCU 215 . . . . . . . . . . . . . . .10A XFSA2ABC5 . . . . . . . . . . . . . .7C XDHLDGCX-4T . . . . . . . . . . . .4A XFC 236 . . . . . . . . . . . . . . . .10A XFCU 218 . . . . . . . . . . . . . . .10A XFSA2ABCD1 . . . . . . . . . . . . .7C 371 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 372 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX XFSA2ABCD2 . . . . . . . . . . . . .7C XFSA2BD2 . . . . . . . . . . . . . . .7C XFSA3ACD1 . . . . . . . . . . . . . .7C XFSA4ABC3 . . . . . . . . . . . . . .7C XFSA2ABCD3 . . . . . . . . . . . . .7C XFSA2BD3 . . . . . . . . . . . . . . .7C XFSA3ACD2 . . . . . . . . . . . . . .7C XFSA4ABC4 . . . . . . . . . . . . . .7C XFSA2ABCD4 . . . . . . . . . . . . .7C XFSA2BD4 . . . . . . . . . . . . . . .7C XFSA3ACD3 . . . . . . . . . . . . . .7C XFSA4ABC5 . . . . . . . . . . . . . .7C XFSA2ABCD5 . . . . . . . . . . . . .7C XFSA2BD5 . . . . . . . . . . . . . . .7C XFSA3ACD4 . . . . . . . . . . . . . .7C XFSA4ABCD1 . . . . . . . . . . . . .7C XFSA2ABCDRA . . . . . . . . . . .7C XFSA2BDRA . . . . . . . . . . . . . .7C XFSA3ACD5 . . . . . . . . . . . . . .7C XFSA4ABCD2 . . . . . . . . . . . . .7C XFSA2ABCRA . . . . . . . . . . . . .7C XFSA2BRA . . . . . . . . . . . . . . .7C XFSA3ACDRA . . . . . . . . . . . . .7C XFSA4ABCD3 . . . . . . . . . . . . .7C XFSA2ABD1 . . . . . . . . . . . . . .7C XFSA30925 . . . . . . . . . . . . . . .7C XFSA3ACRA . . . . . . . . . . . . . .7C XFSA4ABCD4 . . . . . . . . . . . . .7C XFSA2ABD2 . . . . . . . . . . . . . .7C XFSA3101 . . . . . . . . . . . . . . . .7C XFSA3AD1 . . . . . . . . . . . . . . .7C XFSA4ABCD5 . . . . . . . . . . . . .7C XFSA2ABD3 . . . . . . . . . . . . . .7C XFSA31208 . . . . . . . . . . . . . . .7C XFSA3AD2 . . . . . . . . . . . . . . .7C XFSA4ABCDRA . . . . . . . . . . .7C XFSA2ABD4 . . . . . . . . . . . . . .7C XFSA31209 . . . . . . . . . . . . . . .7C XFSA3AD3 . . . . . . . . . . . . . . .7C XFSA4ABCRA . . . . . . . . . . . . .7C XFSA2ABD5 . . . . . . . . . . . . . .7C XFSA3173 . . . . . . . . . . . . . . . .7C XFSA3AD4 . . . . . . . . . . . . . . .7C XFSA4ABD1 . . . . . . . . . . . . . .7C XFSA2ABDRA . . . . . . . . . . . . .7C XFSA3178 . . . . . . . . . . . . . . . .7C XFSA3AD5 . . . . . . . . . . . . . . .7C XFSA4ABD2 . . . . . . . . . . . . . .7C XFSA2ABRA . . . . . . . . . . . . . .7C XFSA3185 . . . . . . . . . . . . . . . .7C XFSA3ADRA . . . . . . . . . . . . . .7C XFSA4ABD3 . . . . . . . . . . . . . .7C XFSA2AC1 . . . . . . . . . . . . . . .7C XFSA32089 . . . . . . . . . . . . . . .7C XFSA3ARA . . . . . . . . . . . . . . .7C XFSA4ABD4 . . . . . . . . . . . . . .7C XFSA2AC2 . . . . . . . . . . . . . . .7C XFSA3223 . . . . . . . . . . . . . . . .7C XFSA3B1 . . . . . . . . . . . . . . . .7C XFSA4ABD5 . . . . . . . . . . . . . .7C XFSA2AC3 . . . . . . . . . . . . . . .7C XFSA3911 . . . . . . . . . . . . . . . .7C XFSA3B2 . . . . . . . . . . . . . . . .7C XFSA4ABDRA . . . . . . . . . . . . .7C XFSA2AC4 . . . . . . . . . . . . . . .7C XFSA3A1 . . . . . . . . . . . . . . . .7C XFSA3B3 . . . . . . . . . . . . . . . .7C XFSA4ABRA . . . . . . . . . . . . . .7C XFSA2AC5 . . . . . . . . . . . . . . .7C XFSA3A2 . . . . . . . . . . . . . . . .7C XFSA3B4 . . . . . . . . . . . . . . . .7C XFSA4AC1 . . . . . . . . . . . . . . .7C XFSA2ACD1 . . . . . . . . . . . . . .7C XFSA3A3 . . . . . . . . . . . . . . . .7C XFSA3B5 . . . . . . . . . . . . . . . .7C XFSA4AC2 . . . . . . . . . . . . . . .7C XFSA2ACD2 . . . . . . . . . . . . . .7C XFSA3A4 . . . . . . . . . . . . . . . .7C XFSA3BC1 . . . . . . . . . . . . . . .7C XFSA4AC3 . . . . . . . . . . . . . . .7C XFSA2ACD3 . . . . . . . . . . . . . .7C XFSA3A5 . . . . . . . . . . . . . . . .7C XFSA3BC2 . . . . . . . . . . . . . . .7C XFSA4AC4 . . . . . . . . . . . . . . .7C XFSA2ACD4 . . . . . . . . . . . . . .7C XFSA3AB1 . . . . . . . . . . . . . . .7C XFSA3BC3 . . . . . . . . . . . . . . .7C XFSA4AC5 . . . . . . . . . . . . . . .7C XFSA2ACD5 . . . . . . . . . . . . . .7C XFSA3AB2 . . . . . . . . . . . . . . .7C XFSA3BC4 . . . . . . . . . . . . . . .7C XFSA4ACD1 . . . . . . . . . . . . . .7C XFSA2ACDRA . . . . . . . . . . . . .7C XFSA3AB3 . . . . . . . . . . . . . . .7C XFSA3BC5 . . . . . . . . . . . . . . .7C XFSA4ACD2 . . . . . . . . . . . . . .7C XFSA2ACRA . . . . . . . . . . . . . .7C XFSA3AB4 . . . . . . . . . . . . . . .7C XFSA3BCD1 . . . . . . . . . . . . . .7C XFSA4ACD3 . . . . . . . . . . . . . .7C XFSA2AD1 . . . . . . . . . . . . . . .7C XFSA3AB5 . . . . . . . . . . . . . . .7C XFSA3BCD2 . . . . . . . . . . . . . .7C XFSA4ACD4 . . . . . . . . . . . . . .7C XFSA2AD2 . . . . . . . . . . . . . . .7C XFSA3ABC1 . . . . . . . . . . . . . .7C XFSA3BCD3 . . . . . . . . . . . . . .7C XFSA4ACD5 . . . . . . . . . . . . . .7C XFSA2AD3 . . . . . . . . . . . . . . .7C XFSA3ABC2 . . . . . . . . . . . . . .7C XFSA3BCD4 . . . . . . . . . . . . . .7C XFSA4ACDRA . . . . . . . . . . . . .7C XFSA2AD4 . . . . . . . . . . . . . . .7C XFSA3ABC3 . . . . . . . . . . . . . .7C XFSA3BCD5 . . . . . . . . . . . . . .7C XFSA4ACRA . . . . . . . . . . . . . .7C XFSA2AD5 . . . . . . . . . . . . . . .7C XFSA3ABC4 . . . . . . . . . . . . . .7C XFSA3BCDRA . . . . . . . . . . . . .7C XFSA4AD1 . . . . . . . . . . . . . . .7C XFSA2ADRA . . . . . . . . . . . . . .7C XFSA3ABC5 . . . . . . . . . . . . . .7C XFSA3BCRA . . . . . . . . . . . . . .7C XFSA4AD2 . . . . . . . . . . . . . . .7C XFSA2ARA . . . . . . . . . . . . . . .7C XFSA3ABCD1 . . . . . . . . . . . . .7C XFSA3BD1 . . . . . . . . . . . . . . .7C XFSA4AD3 . . . . . . . . . . . . . . .7C XFSA2B1 . . . . . . . . . . . . . . . .7C XFSA3ABCD2 . . . . . . . . . . . . .7C XFSA3BD2 . . . . . . . . . . . . . . .7C XFSA4AD4 . . . . . . . . . . . . . . .7C XFSA2B2 . . . . . . . . . . . . . . . .7C XFSA3ABCD3 . . . . . . . . . . . . .7C XFSA3BD3 . . . . . . . . . . . . . . .7C XFSA4AD5 . . . . . . . . . . . . . . .7C XFSA2B3 . . . . . . . . . . . . . . . .7C XFSA3ABCD4 . . . . . . . . . . . . .7C XFSA3BD4 . . . . . . . . . . . . . . .7C XFSA4ADRA . . . . . . . . . . . . . .7C XFSA2B4 . . . . . . . . . . . . . . . .7C XFSA3ABCD5 . . . . . . . . . . . . .7C XFSA3BD5 . . . . . . . . . . . . . . .7C XFSA4ARA . . . . . . . . . . . . . . .7C XFSA2B5 . . . . . . . . . . . . . . . .7C XFSA3ABCDRA . . . . . . . . . . .7C XFSA3BDRA . . . . . . . . . . . . . .7C XFSA4B1 . . . . . . . . . . . . . . . .7C XFSA2BC1 . . . . . . . . . . . . . . .7C XFSA3ABCRA . . . . . . . . . . . . .7C XFSA3BRA . . . . . . . . . . . . . . .7C XFSA4B2 . . . . . . . . . . . . . . . .7C XFSA2BC2 . . . . . . . . . . . . . . .7C XFSA3ABD1 . . . . . . . . . . . . . .7C XFSA4A1 . . . . . . . . . . . . . . . .7C XFSA4B3 . . . . . . . . . . . . . . . .7C XFSA2BC3 . . . . . . . . . . . . . . .7C XFSA3ABD2 . . . . . . . . . . . . . .7C XFSA4A2 . . . . . . . . . . . . . . . .7C XFSA4B4 . . . . . . . . . . . . . . . .7C XFSA2BC4 . . . . . . . . . . . . . . .7C XFSA3ABD3 . . . . . . . . . . . . . .7C XFSA4A3 . . . . . . . . . . . . . . . .7C XFSA4B5 . . . . . . . . . . . . . . . .7C XFSA2BC5 . . . . . . . . . . . . . . .7C XFSA3ABD4 . . . . . . . . . . . . . .7C XFSA4A4 . . . . . . . . . . . . . . . .7C XFSA4BC1 . . . . . . . . . . . . . . .7C XFSA2BCD1 . . . . . . . . . . . . . .7C XFSA3ABD5 . . . . . . . . . . . . . .7C XFSA4A5 . . . . . . . . . . . . . . . .7C XFSA4BC2 . . . . . . . . . . . . . . .7C XFSA2BCD2 . . . . . . . . . . . . . .7C XFSA3ABDRA . . . . . . . . . . . . .7C XFSA4AB1 . . . . . . . . . . . . . . .7C XFSA4BC3 . . . . . . . . . . . . . . .7C XFSA2BCD3 . . . . . . . . . . . . . .7C XFSA3ABRA . . . . . . . . . . . . . .7C XFSA4AB2 . . . . . . . . . . . . . . .7C XFSA4BC4 . . . . . . . . . . . . . . .7C XFSA2BCD4 . . . . . . . . . . . . . .7C XFSA3AC1 . . . . . . . . . . . . . . .7C XFSA4AB3 . . . . . . . . . . . . . . .7C XFSA4BC5 . . . . . . . . . . . . . . .7C XFSA2BCD5 . . . . . . . . . . . . . .7C XFSA3AC2 . . . . . . . . . . . . . . .7C XFSA4AB4 . . . . . . . . . . . . . . .7C XFSA4BCD1 . . . . . . . . . . . . . .7C XFSA2BCDRA . . . . . . . . . . . . .7C XFSA3AC3 . . . . . . . . . . . . . . .7C XFSA4AB5 . . . . . . . . . . . . . . .7C XFSA4BCD2 . . . . . . . . . . . . . .7C XFSA2BCRA . . . . . . . . . . . . . .7C XFSA3AC4 . . . . . . . . . . . . . . .7C XFSA4ABC1 . . . . . . . . . . . . . .7C XFSA4BCD3 . . . . . . . . . . . . . .7C XFSA2BD1 . . . . . . . . . . . . . . .7C XFSA3AC5 . . . . . . . . . . . . . . .7C XFSA4ABC2 . . . . . . . . . . . . . .7C XFSA4BCD4 . . . . . . . . . . . . . .7C 372 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 373 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section XFSA4BCD5 . . . . . . . . . . . . . .7C XGC 30 L . . . . . . . . . . . . . . . .5A XHD-3 NOT INSTALLED . . . . .5A XHSPL . . . . . . . . . . . . . . . . . .9A XFSA4BCDRA . . . . . . . . . . . . .7C XGC 30 L N4 . . . . . . . . . . . . . .5A XHD-4 INSTALLED . . . . . . . . .5A XHSR . . . . . . . . . . . . . . . . . . .9A XFSA4BCRA . . . . . . . . . . . . . .7C XGC 30 N4 . . . . . . . . . . . . . . .5A XHD-4 NOT INSTALLED . . . . .5A XHSS . . . . . . . . . . . . . . . . . . .9A XFSA4BD1 . . . . . . . . . . . . . . .7C XGC 30 SLF . . . . . . . . . . . . . .5A XHDMC . . . . . . . . . . . . . . . . .9A XHSSC . . . . . . . . . . . . . . . . . .9A XFSA4BD2 . . . . . . . . . . . . . . .7C XGC 30 SLF N4 . . . . . . . . . . . .5A XHDMCS . . . . . . . . . . . . . . . .9A XHSSL . . . . . . . . . . . . . . . . . .9A XFSA4BD3 . . . . . . . . . . . . . . .7C XGC 40 . . . . . . . . . . . . . . . . . .5A XHDPB . . . . . . . . . . . . . . . . . .9A XHSSPL . . . . . . . . . . . . . . . . .9A XFSA4BD4 . . . . . . . . . . . . . . .7C XGC 40 L . . . . . . . . . . . . . . . .5A XHDPBS . . . . . . . . . . . . . . . . .9A XHSSR . . . . . . . . . . . . . . . . . .9A XFSA4BD5 . . . . . . . . . . . . . . .7C XGC 40 L N4 . . . . . . . . . . . . . .5A XHDPL . . . . . . . . . . . . . . . . . .9A XHSSS . . . . . . . . . . . . . . . . . .9A XFSA4BDRA . . . . . . . . . . . . . .7C XGC 40 N4 . . . . . . . . . . . . . . .5A XHF-2 INSTALLED . . . . . . . . .5A XHSSSPL . . . . . . . . . . . . . . . .9A XFSA4BRA . . . . . . . . . . . . . . .7C XGC 40 SLF . . . . . . . . . . . . . .5A XHF-2 NOT INSTALLED . . . . .5A XIF 030303 . . . . . . . . . . . . . . .5B XFSAC1 . . . . . . . . . . . . . . . . .7C XGC 40 SLF N4 . . . . . . . . . . . .5A XHF-3 INSTALLED . . . . . . . . .5A XIF 030603 . . . . . . . . . . . . . . .5B XFSAC2 . . . . . . . . . . . . . . . . .7C XGC 52 . . . . . . . . . . . . . . . . . .5A XHF-3 NOT INSTALLED . . . . .5A XIF 030703 . . . . . . . . . . . . . . .5B XFSAC3 . . . . . . . . . . . . . . . . .7C XGC 52 L . . . . . . . . . . . . . . . .5A XHF-4 INSTALLED . . . . . . . . .5A XIF 030903 . . . . . . . . . . . . . . .5B XFSAC4 . . . . . . . . . . . . . . . . .7C XGC 52 L N4 . . . . . . . . . . . . . .5A XHF-4 NOT INSTALLED . . . . .5A XIF 031103 . . . . . . . . . . . . . . .5B XFSAC5 . . . . . . . . . . . . . . . . .7C XGC 52 N4 . . . . . . . . . . . . . . .5A XHFA 31 GB N4 . . . . . . . . . . .5C XIF 031303 . . . . . . . . . . . . . . .5B XFSACD1 . . . . . . . . . . . . . . . .7C XGC 52 SLF . . . . . . . . . . . . . .5A XHFA 31 N4 . . . . . . . . . . . . . .5C XIF 031503 . . . . . . . . . . . . . . .5B XFSACD2 . . . . . . . . . . . . . . . .7C XGC 52 SLF N4 . . . . . . . . . . . .5A XHFA 32 GB N4 . . . . . . . . . . .5C XIF 031803 . . . . . . . . . . . . . . .5B XFSACD3 . . . . . . . . . . . . . . . .7C XGC 66 . . . . . . . . . . . . . . . . . .5A XHFA 32 N4 . . . . . . . . . . . . . .5C XIF 032403 . . . . . . . . . . . . . . .5B XFSACD4 . . . . . . . . . . . . . . . .7C XGC 66 L . . . . . . . . . . . . . . . .5A XHFA 33 GB N4 . . . . . . . . . . .5C XIF 033003 . . . . . . . . . . . . . . .5B XFSACD5 . . . . . . . . . . . . . . . .7C XGC 66 L N4 . . . . . . . . . . . . . .5A XHFA 33 N4 . . . . . . . . . . . . . .5C XIF 033603 . . . . . . . . . . . . . . .5B XFSACDRA . . . . . . . . . . . . . . .7C XGC 66 N4 . . . . . . . . . . . . . . .5A XHFA 41 GB N4 . . . . . . . . . . .5C XIF 040604 . . . . . . . . . . . . . . .5B XFSACRA . . . . . . . . . . . . . . . .7C XGC 66 SLF . . . . . . . . . . . . . .5A XHFA 41 N4 . . . . . . . . . . . . . .5C XIF 041204 . . . . . . . . . . . . . . .5B XFSAD1 . . . . . . . . . . . . . . . . .7C XGC 66 SLF N4 . . . . . . . . . . . .5A XHFA 42 GB N4 . . . . . . . . . . .5C XIF 060606 . . . . . . . . . . . . . . .5B XFSAD2 . . . . . . . . . . . . . . . . .7C XGC 80 . . . . . . . . . . . . . . . . . .5A XHFA 42 N4 . . . . . . . . . . . . . .5C XIF 060608 . . . . . . . . . . . . . . .5B XFSAD3 . . . . . . . . . . . . . . . . .7C XGC 80 L . . . . . . . . . . . . . . . .5A XHFA 43 GB N4 . . . . . . . . . . .5C XIF 061206 . . . . . . . . . . . . . . .5B XFSAD4 . . . . . . . . . . . . . . . . .7C XGC 80 L N4 . . . . . . . . . . . . . .5A XHFA 43 N4 . . . . . . . . . . . . . .5C XIF 061806 . . . . . . . . . . . . . . .5B XFSAD5 . . . . . . . . . . . . . . . . .7C XGC 80 N4 . . . . . . . . . . . . . . .5A XHFG . . . . . . . . . . . . . . . . . . .5C XIF 062406 . . . . . . . . . . . . . . .5B XFSADRA . . . . . . . . . . . . . . . .7C XGC 80 SLF . . . . . . . . . . . . . .5A XHKSC . . . . . . . . . . . . . . . . . .9A XIF 063606 . . . . . . . . . . . . . . .5B XFSB2 . . . . . . . . . . . . . . . . . . .7C XGC 80 SLF N4 . . . . . . . . . . . .5A XHKSL . . . . . . . . . . . . . . . . . .9A XIF 070704 . . . . . . . . . . . . . . .5B XFSB3 . . . . . . . . . . . . . . . . . . .7C XGW 0303 . . . . . . . . . . . . . . .5A XHKSR . . . . . . . . . . . . . . . . . .9A XIF 071603 . . . . . . . . . . . . . . .5B XFSB4 . . . . . . . . . . . . . . . . . . .7C XGW 0305 . . . . . . . . . . . . . . .5A XHKSS . . . . . . . . . . . . . . . . . .9A XIF 083206 . . . . . . . . . . . . . . .5B XFSC . . . . . . . . . . . . . . . . . . .7C XGW 0307 . . . . . . . . . . . . . . .5A XHKSSC . . . . . . . . . . . . . . . . .9A XIFC 030303 . . . . . . . . . . . . . .5B XFSC-1 . . . . . . . . . . . . . . . . . .7C XGW 0505 . . . . . . . . . . . . . . .5A XHKSSL . . . . . . . . . . . . . . . . .9A XIFC 030603 . . . . . . . . . . . . . .5B XFSC-2 . . . . . . . . . . . . . . . . . .7C XGW 0509 . . . . . . . . . . . . . . .5A XHKSSR . . . . . . . . . . . . . . . . .9A XIFC 030703 . . . . . . . . . . . . . .5B XFSC-3 . . . . . . . . . . . . . . . . . .7C XGW 0707 . . . . . . . . . . . . . . .5A XHKSSS . . . . . . . . . . . . . . . . .9A XIFC 030903 . . . . . . . . . . . . . .5B XFSC-4 . . . . . . . . . . . . . . . . . .7C XGW 0713 . . . . . . . . . . . . . . .5A XHMCD . . . . . . . . . . . . . . . . .9A XIFC 031103 . . . . . . . . . . . . . .5B XFSC-5 . . . . . . . . . . . . . . . . . .7C XGW 0909 . . . . . . . . . . . . . . .5A XHMCMD . . . . . . . . . . . . . . . .9A XIFC 031303 . . . . . . . . . . . . . .5B XGC 10 . . . . . . . . . . . . . . . . . .5A XGW 1111 . . . . . . . . . . . . . . .5A XHMCMSD . . . . . . . . . . . . . . .9A XIFC 031503 . . . . . . . . . . . . . .5B XGC 10 L . . . . . . . . . . . . . . . .5A XGW 1313 . . . . . . . . . . . . . . .5A XHMCSD . . . . . . . . . . . . . . . .9A XIFC 031803 . . . . . . . . . . . . . .5B XGC 10 L N4 . . . . . . . . . . . . . .5A XHB-2 INSTALLED . . . . . . . . .5A XHPB . . . . . . . . . . . . . . . . . . .9A XIFC 032403 . . . . . . . . . . . . . .5B XGC 10 N4 . . . . . . . . . . . . . . .5A XHB-2 NOT INSTALLED . . . . .5A XHPBM . . . . . . . . . . . . . . . . . .9A XIFC 033003 . . . . . . . . . . . . . .5B XGC 10 SLF . . . . . . . . . . . . . .5A XHB-4 INSTALLED . . . . . . . . .5A XHPBMS . . . . . . . . . . . . . . . .9A XIFC 033603 . . . . . . . . . . . . . .5B XGC 10 SLF N4 . . . . . . . . . . . .5A XHB-4 NOT INSTALLED . . . . .5A XHPBPL . . . . . . . . . . . . . . . . .9A XIFC 040604 . . . . . . . . . . . . . .5B XGC 20 . . . . . . . . . . . . . . . . . .5A XHC- 2 INSTALLED . . . . . . . . .5A XHPBS . . . . . . . . . . . . . . . . . .9A XIFC 041204 . . . . . . . . . . . . . .5B XGC 20 L . . . . . . . . . . . . . . . .5A XHC- 3 INSTALLED . . . . . . . . .5A XHPBSPL . . . . . . . . . . . . . . . .9A XIFC 060606 . . . . . . . . . . . . . .5B XGC 20 L N4 . . . . . . . . . . . . . .5A XHC-2 NOT INSTALLED . . . . .5A XHPL . . . . . . . . . . . . . . . . . . .9A XIFC 060608 . . . . . . . . . . . . . .5B XGC 20 N4 . . . . . . . . . . . . . . .5A XHC-3 NOT INSTALLED . . . . .5A XHPPM . . . . . . . . . . . . . . . . . .9A XIFC 061206 . . . . . . . . . . . . . .5B XGC 20 SLF . . . . . . . . . . . . . .5A XHD- 2 INSTALLED . . . . . . . . .5A XHPPMS . . . . . . . . . . . . . . . . .9A XIFC 070704 . . . . . . . . . . . . . .5B XGC 20 SLF N4 . . . . . . . . . . . .5A XHD- 3 INSTALLED . . . . . . . . .5A XHSC . . . . . . . . . . . . . . . . . . .9A XIHDCX 2 . . . . . . . . . . . . . . . .4A XGC 30 . . . . . . . . . . . . . . . . . .5A XHD-2 NOT INSTALLED . . . . .5A XHSL . . . . . . . . . . . . . . . . . . .9A XIHDCX 2L . . . . . . . . . . . . . . .4A 373 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 374 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX XIHDCX 3 . . . . . . . . . . . . . . . .4A XIHSCDGC4 . . . . . . . . . . . . . .4A XJAB 570 N4 . . . . . . . . . . . .10A XJAT 890 N4 . . . . . . . . . . . . .10A XIHDCX 3L . . . . . . . . . . . . . . .4A XIHSCFC2 . . . . . . . . . . . . . . . .4A XJAB 690 . . . . . . . . . . . . . . .10A XJAX 26 . . . . . . . . . . . . . . . .10A XIHDGCX 2 . . . . . . . . . . . . . . .4A XIHSCFC3 . . . . . . . . . . . . . . . .4A XJAB 690 N4 . . . . . . . . . . . .10A XJAX 26 N4 . . . . . . . . . . . . .10A XIHDGCX 2L . . . . . . . . . . . . . .4A XIHSCFC4 . . . . . . . . . . . . . . . .4A XJAB 890 . . . . . . . . . . . . . . .10A XJAX 36 . . . . . . . . . . . . . . . .10A XIHDGCX 3 . . . . . . . . . . . . . . .4A XIHSDC3 . . . . . . . . . . . . . . . .4A XJAB 890 N4 . . . . . . . . . . . .10A XJAX 36 N4 . . . . . . . . . . . . .10A XIHDGCX 3L . . . . . . . . . . . . . .4A XIHSDDC4 . . . . . . . . . . . . . . .4A XJAC 26 . . . . . . . . . . . . . . . .10A XJAX 46 . . . . . . . . . . . . . . . .10A XIHFCX 2 . . . . . . . . . . . . . . . .4A XIHSDDGC3 . . . . . . . . . . . . . .4A XJAC 26 N4 . . . . . . . . . . . . .10A XJAX 46 N4 . . . . . . . . . . . . .10A XIHFCX 2L . . . . . . . . . . . . . . .4A XIHSDDGC4 . . . . . . . . . . . . . .4A XJAC 36 . . . . . . . . . . . . . . . .10A XJAX 570 . . . . . . . . . . . . . . .10A XIHFCX 3 . . . . . . . . . . . . . . . .4A XIHSDFC3 . . . . . . . . . . . . . . . .4A XJAC 36 N4 . . . . . . . . . . . . .10A XJAX 570 N4 . . . . . . . . . . . .10A XIHFCX 3L . . . . . . . . . . . . . . .4A XIHSDFC4 . . . . . . . . . . . . . . . .4A XJAC 46 . . . . . . . . . . . . . . . .10A XJAX 690 . . . . . . . . . . . . . . .10A XIHFGCX 2 . . . . . . . . . . . . . . .4A XIHSLDC2 . . . . . . . . . . . . . . . .4A XJAC 46 N4 . . . . . . . . . . . . .10A XJAX 690 N4 . . . . . . . . . . . .10A XIHFGCX 2L . . . . . . . . . . . . . .4A XIHSLDC3 . . . . . . . . . . . . . . . .4A XJAC 570 . . . . . . . . . . . . . . .10A XJAX 890 . . . . . . . . . . . . . . .10A XIHFGCX 3 . . . . . . . . . . . . . . .4A XIHSLDC4 . . . . . . . . . . . . . . . .4A XJAC 570 N4 . . . . . . . . . . . .10A XJAX 890 N4 . . . . . . . . . . . .10A XIHFGCX 3L . . . . . . . . . . . . . .4A XIHSLDGC2 . . . . . . . . . . . . . .4A XJAC 690 . . . . . . . . . . . . . . .10A XJAY . . . . . . . . . . . . . . . . . . . .5E XIHLDCX . . . . . . . . . . . . . . . .4A XIHSLDGC3 . . . . . . . . . . . . . .4A XJAC 690 N4 . . . . . . . . . . . .10A XJAY N4 . . . . . . . . . . . . . . . . .5E XIHLDGCX . . . . . . . . . . . . . . .4A XIHSLDGC4 . . . . . . . . . . . . . .4A XJAC 890 . . . . . . . . . . . . . . .10A XJAYRC . . . . . . . . . . . . . . . . .5E XIHLFCX . . . . . . . . . . . . . . . . .4A XIHSLFC2 . . . . . . . . . . . . . . . .4A XJAC 890 N4 . . . . . . . . . . . .10A XJBC . . . . . . . . . . . . . . . . . . . .5E XIHLFGCX . . . . . . . . . . . . . . . .4A XIHSLFC3 . . . . . . . . . . . . . . . .4A XJAD 10 . . . . . . . . . . . . . . . .10A XJBCC 2 . . . . . . . . . . . . . . . . .5E XIHMDCX . . . . . . . . . . . . . . . .4A XIHSLFC4 . . . . . . . . . . . . . . . .4A XJAD 13 . . . . . . . . . . . . . . . .10A XJBCC 3 . . . . . . . . . . . . . . . . .5E XIHMDCX2 . . . . . . . . . . . . . . .4A XIHSTDC2 . . . . . . . . . . . . . . . .4A XJAD 36 . . . . . . . . . . . . . . . .10A XJD . . . . . . . . . . . . . . . . . . . . .6A XIHMDCX2L . . . . . . . . . . . . . .4A XIHSTDC3 . . . . . . . . . . . . . . . .4A XJAD 36 N4 . . . . . . . . . . . . .10A XJD N4 . . . . . . . . . . . . . . . . . .6A XIHMDCXL . . . . . . . . . . . . . . .4A XIHSTDC4 . . . . . . . . . . . . . . . .4A XJAD 4 . . . . . . . . . . . . . . . . .10A XJDA . . . . . . . . . . . . . . . . . . .6A XIHMDGCX . . . . . . . . . . . . . . .4A XIHSTDGC2 . . . . . . . . . . . . . .4A XJAD 46 . . . . . . . . . . . . . . . .10A XJDA N4 . . . . . . . . . . . . . . . . .6A XIHMDGCX2 . . . . . . . . . . . . . .4A XIHSTDGC3 . . . . . . . . . . . . . .4A XJAD 46 N4 . . . . . . . . . . . . .10A XJDAO . . . . . . . . . . . . . . . . . .6A XIHMDGCX2L . . . . . . . . . . . . .4A XIHSTDGC4 . . . . . . . . . . . . . .4A XJAD 6 . . . . . . . . . . . . . . . . .10A XJDFGC . . . . . . . . . . . . . . . . .6A XIHMDGCXL . . . . . . . . . . . . . .4A XIHSTFC2 . . . . . . . . . . . . . . . .4A XJADC . . . . . . . . . . . . . . . . .10A XJDFGC N4 . . . . . . . . . . . . . .6A XIHMFCX . . . . . . . . . . . . . . . .4A XIHSTFC3 . . . . . . . . . . . . . . . .4A XJAL 26 . . . . . . . . . . . . . . . .10A XJDGC . . . . . . . . . . . . . . . . . .6A XIHMFCX2 . . . . . . . . . . . . . . .4A XIHSTFC4 . . . . . . . . . . . . . . . .4A XJAL 26 N4 . . . . . . . . . . . . . .10A XJDGC N4 . . . . . . . . . . . . . . .6A XIHMFCX2L . . . . . . . . . . . . . .4A XIHSXDC2 . . . . . . . . . . . . . . .4A XJAL 36 . . . . . . . . . . . . . . . .10A XJDO . . . . . . . . . . . . . . . . . . .6A XIHMFCXL . . . . . . . . . . . . . . .4A XIHSXDC3 . . . . . . . . . . . . . . .4A XJAL 36 N4 . . . . . . . . . . . . . .10A XJFC 2 . . . . . . . . . . . . . . . . . .5E XIHMFGCX . . . . . . . . . . . . . . .4A XIHSXDC4 . . . . . . . . . . . . . . .4A XJAL 46 . . . . . . . . . . . . . . . .10A XJFC 3 . . . . . . . . . . . . . . . . . .5E XIHMFGCX2 . . . . . . . . . . . . . .4A XIHSXDGC2 . . . . . . . . . . . . . .4A XJAL 46 N4 . . . . . . . . . . . . . .10A XJFC 3C2 . . . . . . . . . . . . . . . .5E XIHMFGCX2L . . . . . . . . . . . . .4A XIHSXDGC3 . . . . . . . . . . . . . .4A XJAL 570 . . . . . . . . . . . . . . .10A XJFC 3C3 . . . . . . . . . . . . . . . .5E XIHMFGCXL . . . . . . . . . . . . . .4A XIHSXDGC4 . . . . . . . . . . . . . .4A XJAL 570 N4 . . . . . . . . . . . . .10A XJFCC 2 . . . . . . . . . . . . . . . . .5E XIHMKFCX . . . . . . . . . . . . . . .4A XIHSXFC2 . . . . . . . . . . . . . . . .4A XJAL 690 . . . . . . . . . . . . . . .10A XJFCC 3 . . . . . . . . . . . . . . . . .5E XIHMKFGCX . . . . . . . . . . . . . .4A XIHSXFC3 . . . . . . . . . . . . . . . .4A XJAL 690 N4 . . . . . . . . . . . . .10A XJHA . . . . . . . . . . . . . . . . . . .6A XIHSBDC2 . . . . . . . . . . . . . . .4A XIHSXFC4 . . . . . . . . . . . . . . . .4A XJAL 890 . . . . . . . . . . . . . . .10A XJHA N4 . . . . . . . . . . . . . . . . .6A XIHSBDC3 . . . . . . . . . . . . . . .4A XIHSYDC23 . . . . . . . . . . . . . .4A XJAL 890 N4 . . . . . . . . . . . . .10A XJHAB . . . . . . . . . . . . . . . . . .6A XIHSBDC4 . . . . . . . . . . . . . . .4A XIHSYDGC23 . . . . . . . . . . . . .4A XJAO . . . . . . . . . . . . . . . . . .10A XJHAB N4 . . . . . . . . . . . . . . .6A XIHSBDGC2 . . . . . . . . . . . . . .4A XIHSYFC23 . . . . . . . . . . . . . . .4A XJAT 26 . . . . . . . . . . . . . . . .10A XJHABGC . . . . . . . . . . . . . . . .6A XIHSBDGC3 . . . . . . . . . . . . . .4A XJA 6 . . . . . . . . . . . . . . . . . .10A XJAT 26 N4 . . . . . . . . . . . . . .10A XJHABGC N4 . . . . . . . . . . . . .6A XIHSBDGC4 . . . . . . . . . . . . . .4A XJA 6S . . . . . . . . . . . . . . . . .10A XJAT 36 . . . . . . . . . . . . . . . .10A XJHAD 12 . . . . . . . . . . . . . . . .6A XIHSBFC2 . . . . . . . . . . . . . . . .4A XJA 8 . . . . . . . . . . . . . . . . . .10A XJAT 36 N4 . . . . . . . . . . . . . .10A XJHAD 12 N4 . . . . . . . . . . . . .6A XIHSBFC3 . . . . . . . . . . . . . . . .4A XJAB 26 . . . . . . . . . . . . . . . .10A XJAT 46 . . . . . . . . . . . . . . . .10A XJHAD 6 . . . . . . . . . . . . . . . . .6A XIHSBFC4 . . . . . . . . . . . . . . . .4A XJAB 26 N4 . . . . . . . . . . . . .10A XJAT 46 N4 . . . . . . . . . . . . . .10A XJHAD 6 N4 . . . . . . . . . . . . . .6A XIHSCDC2 . . . . . . . . . . . . . . .4A XJAB 36 . . . . . . . . . . . . . . . .10A XJAT 570 . . . . . . . . . . . . . . .10A XJHAD 9 . . . . . . . . . . . . . . . . .6A XIHSCDC3 . . . . . . . . . . . . . . .4A XJAB 36 N4 . . . . . . . . . . . . .10A XJAT 570 N4 . . . . . . . . . . . . .10A XJHAD 9 N4 . . . . . . . . . . . . . .6A XIHSCDC4 . . . . . . . . . . . . . . .4A XJAB 46 . . . . . . . . . . . . . . . .10A XJAT 690 . . . . . . . . . . . . . . .10A XJHAGC . . . . . . . . . . . . . . . . .6A XIHSCDGC2 . . . . . . . . . . . . . .4A XJAB 46 N4 . . . . . . . . . . . . .10A XJAT 690 N4 . . . . . . . . . . . . .10A XJHAGC N4 . . . . . . . . . . . . . .6A XIHSCDGC3 . . . . . . . . . . . . . .4A XJAB 570 . . . . . . . . . . . . . . .10A XJAT 890 . . . . . . . . . . . . . . .10A XJHB . . . . . . . . . . . . . . . . . . .6A 374 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 375 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section XJHB N4 . . . . . . . . . . . . . . . . .6A XJLD 4 N4 . . . . . . . . . . . . . . .6A XJTD 6 N4 . . . . . . . . . . . . . . .6A XLA-GC . . . . . . . . . . . . . . . . . .9A XJHBGC . . . . . . . . . . . . . . . . .6A XJLD 6 . . . . . . . . . . . . . . . . . .6A XJTFGC . . . . . . . . . . . . . . . . .6A XLA-GCH . . . . . . . . . . . . . . . .9A XJHBGC N4 . . . . . . . . . . . . . .6A XJLD 6 N4 . . . . . . . . . . . . . . .6A XJTFGC N4 . . . . . . . . . . . . . . .6A XLA-GH . . . . . . . . . . . . . . . . . .9A XJHC . . . . . . . . . . . . . . . . . . .6A XJLGC . . . . . . . . . . . . . . . . . .6A XJTGC . . . . . . . . . . . . . . . . . .6A XLAH . . . . . . . . . . . . . . . . . . .9A XJHC N4 . . . . . . . . . . . . . . . . .6A XJLGC N4 . . . . . . . . . . . . . . . .6A XJTGC N4 . . . . . . . . . . . . . . . .6A XLAL-GH . . . . . . . . . . . . . . . . .9A XJHCD 12 . . . . . . . . . . . . . . . .6A XJM . . . . . . . . . . . . . . . . . . . .6A XJTO . . . . . . . . . . . . . . . . . . .6A XLAS . . . . . . . . . . . . . . . . . . .9A XJHCD 12 N4 . . . . . . . . . . . . .6A XJM N4 . . . . . . . . . . . . . . . . .6A XJU 23 . . . . . . . . . . . . . . . . . .5E XLAS-G . . . . . . . . . . . . . . . . . .9A XJHCD 6 . . . . . . . . . . . . . . . . .6A XJMA . . . . . . . . . . . . . . . . . . .6A XJUC 2 . . . . . . . . . . . . . . . . . .5E XLAS-GH . . . . . . . . . . . . . . . .9A XJHCD 6 N4 . . . . . . . . . . . . . .6A XJMA N4 . . . . . . . . . . . . . . . .6A XJUC 2 XJUDC . . . . . . . . . . . .5E XLB . . . . . . . . . . . . . . . . . . . . .9A XJHCD 9 . . . . . . . . . . . . . . . . .6A XJMAGC . . . . . . . . . . . . . . . . .6A XJUC 3 . . . . . . . . . . . . . . . . . .5E XLB-G . . . . . . . . . . . . . . . . . . .9A XJHCD 9 N4 . . . . . . . . . . . . . .6A XJMAGC N4 . . . . . . . . . . . . . .6A XJUC 3 XJUDC . . . . . . . . . . . .5E XLB-GC . . . . . . . . . . . . . . . . . .9A XJHCGC . . . . . . . . . . . . . . . . .6A XJMC . . . . . . . . . . . . . . . . . . .6A XJUDC . . . . . . . . . . . . . . . . . .5E XLB-GCH . . . . . . . . . . . . . . . .9A XJHCGC N4 . . . . . . . . . . . . . .6A XJMC N4 . . . . . . . . . . . . . . . .6A XJULB 2 . . . . . . . . . . . . . . . . .5E XLB-GH . . . . . . . . . . . . . . . . . .9A XJHO . . . . . . . . . . . . . . . . . . .6A XJMCGC . . . . . . . . . . . . . . . . .6A XJULB 2 XJUDC . . . . . . . . . . .5E XLBL-G . . . . . . . . . . . . . . . . . .9A XJK . . . . . . . . . . . . . . . . . . . . .6A XJMCGC N4 . . . . . . . . . . . . . .6A XJULB 3 . . . . . . . . . . . . . . . . .5E XLBL-GH . . . . . . . . . . . . . . . . .9A XJK N4 . . . . . . . . . . . . . . . . . .6A XJMGC . . . . . . . . . . . . . . . . . .6A XJULB 3 XJUDC . . . . . . . . . . .5E XLBS . . . . . . . . . . . . . . . . . . .9A XJKA . . . . . . . . . . . . . . . . . . . .6A XJMGC N4 . . . . . . . . . . . . . . .6A XJW 3 . . . . . . . . . . . . . . . . . . .6A XLBS-G . . . . . . . . . . . . . . . . . .9A XJKA N4 . . . . . . . . . . . . . . . . .6A XJN 12 . . . . . . . . . . . . . . . . . .6A XJW 3 N4 . . . . . . . . . . . . . . . .6A XLBS-GH . . . . . . . . . . . . . . . .9A XJKAD 12 . . . . . . . . . . . . . . . .6A XJN 12 N4 . . . . . . . . . . . . . . .6A XJW 5 . . . . . . . . . . . . . . . . . . .6A XLC . . . . . . . . . . . . . . . . . . . . .9A XJKAD 12 N4 . . . . . . . . . . . . .6A XJN 6 . . . . . . . . . . . . . . . . . . .6A XJW 5 N4 . . . . . . . . . . . . . . . .6A XLC-G . . . . . . . . . . . . . . . . . . .9A XJKAD 18 . . . . . . . . . . . . . . . .6A XJN 6 N4 . . . . . . . . . . . . . . . .6A XJWH . . . . . . . . . . . . . . . . . . .6A XLC-GC . . . . . . . . . . . . . . . . . .9A XJKAD 18 N4 . . . . . . . . . . . . .6A XJNGC 12 . . . . . . . . . . . . . . . .6A XJWH 12 . . . . . . . . . . . . . . . .6A XLC-GCH . . . . . . . . . . . . . . . .9A XJKAD 6 . . . . . . . . . . . . . . . . .6A XJNGC 12 N4 . . . . . . . . . . . . .6A XJWH 12 N4 . . . . . . . . . . . . . .6A XLC-GH . . . . . . . . . . . . . . . . . .9A XJKAD 6 N4 . . . . . . . . . . . . . .6A XJNGC 6 . . . . . . . . . . . . . . . . .6A XJWH 6 . . . . . . . . . . . . . . . . .6A XLCS . . . . . . . . . . . . . . . . . . .9A XJKAGC . . . . . . . . . . . . . . . . .6A XJNGC 6 N4 . . . . . . . . . . . . . .6A XJWH 6 N4 . . . . . . . . . . . . . . .6A XLCS-G . . . . . . . . . . . . . . . . . .9A XJKAGC N4 . . . . . . . . . . . . . .6A XJNO . . . . . . . . . . . . . . . . . . .6A XJWH 9 . . . . . . . . . . . . . . . . .6A XLCS-GH . . . . . . . . . . . . . . . .9A XJKB . . . . . . . . . . . . . . . . . . . .6A XJOGC . . . . . . . . . . . . . . . . . .6A XJWH 9 N4 . . . . . . . . . . . . . . .6A XLG . . . . . . . . . . . . . . . . . . . .9A XJKB N4 . . . . . . . . . . . . . . . . .6A XJOGC N4 . . . . . . . . . . . . . . .6A XJWH N4 . . . . . . . . . . . . . . . .6A XLG-G . . . . . . . . . . . . . . . . . . .9A XJKBGC . . . . . . . . . . . . . . . . .6A XJS . . . . . . . . . . . . . . . . . . . . .6A XJWHGC N4 . . . . . . . . . . . . . .6A XLG-GC . . . . . . . . . . . . . . . . . .9A XJKBGC N4 . . . . . . . . . . . . . .6A XJS N4 . . . . . . . . . . . . . . . . . .6A XJWHGCX . . . . . . . . . . . . . . .6A XLG-GCH . . . . . . . . . . . . . . . .9A XJKD 12 . . . . . . . . . . . . . . . . .6A XJSD . . . . . . . . . . . . . . . . . . .6A XJWO . . . . . . . . . . . . . . . . . . .6A XLG-GH . . . . . . . . . . . . . . . . .9A XJKD 12 N4 . . . . . . . . . . . . . .6A XJSD N4 . . . . . . . . . . . . . . . . .6A XJWT . . . . . . . . . . . . . . . . . . .6A XLGL-GH . . . . . . . . . . . . . . . .9A XJKD 18 . . . . . . . . . . . . . . . . .6A XJSO . . . . . . . . . . . . . . . . . . .6A XJWT 10 . . . . . . . . . . . . . . . . .6A XLGS . . . . . . . . . . . . . . . . . . .9A XJKD 18 N4 . . . . . . . . . . . . . .6A XJSWGC . . . . . . . . . . . . . . . . .6A XJWT 10 N4 . . . . . . . . . . . . . .6A XLGS-G . . . . . . . . . . . . . . . . . .9A XJKD 6 . . . . . . . . . . . . . . . . . .6A XJSWGC N4 . . . . . . . . . . . . . .6A XJWT 13 . . . . . . . . . . . . . . . . .6A XLGS-GH . . . . . . . . . . . . . . . .9A XJKD 6 N4 . . . . . . . . . . . . . . .6A XJT . . . . . . . . . . . . . . . . . . . . .6A XJWT 13 N4 . . . . . . . . . . . . . .6A XLP 30320 . . . . . . . . . . . . . . .8C XJKGC . . . . . . . . . . . . . . . . . .6A XJT N4 . . . . . . . . . . . . . . . . . .6A XJWT 4 . . . . . . . . . . . . . . . . . .6A XLPA . . . . . . . . . . . . . . . . . . . .9A XJKGC N4 . . . . . . . . . . . . . . . .6A XJTB . . . . . . . . . . . . . . . . . . . .5E XJWT 4 N4 . . . . . . . . . . . . . . .6A XLPAS . . . . . . . . . . . . . . . . . . .9A XJKO . . . . . . . . . . . . . . . . . . .6A XJTB 2 . . . . . . . . . . . . . . . . . .5E XJWT 6 . . . . . . . . . . . . . . . . . .6A XLPB . . . . . . . . . . . . . . . . . . .9A XJL . . . . . . . . . . . . . . . . . . . . .6A XJTB 2 XJUDC . . . . . . . . . . . .5E XJWT 6 N4 . . . . . . . . . . . . . . .6A XLPBS . . . . . . . . . . . . . . . . . .9A XJL N4 . . . . . . . . . . . . . . . . . .6A XJTB N4 . . . . . . . . . . . . . . . . .5E XJWT N4 . . . . . . . . . . . . . . . .6A XLPC . . . . . . . . . . . . . . . . . . .9A XJLB 2 . . . . . . . . . . . . . . . . . .5E XJTBGC . . . . . . . . . . . . . . . . .5E XJWTGC N4 . . . . . . . . . . . . . .6A XLPCS . . . . . . . . . . . . . . . . . .9A XJLB 2 XJUDC . . . . . . . . . . . .5E XJTBGC N4 . . . . . . . . . . . . . . .5E XJWTGCX . . . . . . . . . . . . . . . .6A XLPG . . . . . . . . . . . . . . . . . . .9A XJLB 3 . . . . . . . . . . . . . . . . . .5E XJTD 10 . . . . . . . . . . . . . . . . .6A XJX . . . . . . . . . . . . . . . . . . . . .6A XLPGS . . . . . . . . . . . . . . . . . .9A XJLB 3 XJUDC . . . . . . . . . . . .5E XJTD 10 N4 . . . . . . . . . . . . . .6A XJX N4 . . . . . . . . . . . . . . . . . .6A XLPR . . . . . . . . . . . . . . . . . . .9A XJLD 10 . . . . . . . . . . . . . . . . .6A XJTD 13 . . . . . . . . . . . . . . . . .6A XJXGC . . . . . . . . . . . . . . . . . .6A XLPRS . . . . . . . . . . . . . . . . . .9A XJLD 10 N4 . . . . . . . . . . . . . .6A XJTD 13 N4 . . . . . . . . . . . . . .6A XJXGC N4 . . . . . . . . . . . . . . . .6A XLPW . . . . . . . . . . . . . . . . . . .9A XJLD 13 . . . . . . . . . . . . . . . . .6A XJTD 4 . . . . . . . . . . . . . . . . . .6A XJXO . . . . . . . . . . . . . . . . . . .6A XLPWS . . . . . . . . . . . . . . . . . .9A XJLD 13 N4 . . . . . . . . . . . . . .6A XJTD 4 N4 . . . . . . . . . . . . . . .6A XLA . . . . . . . . . . . . . . . . . . . . .9A XLR . . . . . . . . . . . . . . . . . . . . .9A XJLD 4 . . . . . . . . . . . . . . . . . .6A XJTD 6 . . . . . . . . . . . . . . . . . .6A XLA-G . . . . . . . . . . . . . . . . . . .9A XLR-G . . . . . . . . . . . . . . . . . . .9A 375 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/10/01 5:28 PM Page 376 Index Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section INDEX XLR-GC . . . . . . . . . . . . . . . . . .9A XLSWS . . . . . . . . . . . . . . . . . .9A XMSH 63 . . . . . . . . . . . . . . . .8C XPB1-N2 . . . . . . . . . . . . . . . . .8A XLR-GCH . . . . . . . . . . . . . . . .9A XLSWS-G . . . . . . . . . . . . . . . .9A XMSH 64 . . . . . . . . . . . . . . . .8C XPB2-1 . . . . . . . . . . . . . . . . . .8A XLR-GH . . . . . . . . . . . . . . . . . .9A XLSWS-GH . . . . . . . . . . . . . . .9A XMSH N4 . . . . . . . . . . . . . . . .8C XPB2-12320B1 . . . . . . . . . . . .8A XLRL-GH . . . . . . . . . . . . . . . . .9A XLW . . . . . . . . . . . . . . . . . . . .9A XMSH-N4 . . . . . . . . . . . . . . . .8C XPB2-12320L1 . . . . . . . . . . . .8A XLRS . . . . . . . . . . . . . . . . . . .9A XLW-G . . . . . . . . . . . . . . . . . .9A XMSQ 65 . . . . . . . . . . . . . . . .8C XPB2-12320L2 . . . . . . . . . . . .8A XLRS-G . . . . . . . . . . . . . . . . . .9A XLW-GC . . . . . . . . . . . . . . . . .9A XMSQ N4 . . . . . . . . . . . . . . . .8C XPB2-12320L2 . . . . . . . . . . . .8A XLRS-GH . . . . . . . . . . . . . . . .9A XLW-GCH . . . . . . . . . . . . . . . .9A XMSQ-N4 . . . . . . . . . . . . . . . .8C XPB2-123L1 . . . . . . . . . . . . . .8A XLSA . . . . . . . . . . . . . . . . . . .9A XLW-GH . . . . . . . . . . . . . . . . .9A XMT . . . . . . . . . . . . . . . . . . . .9A XPB2-18320B1 . . . . . . . . . . . .8A XLSA-G . . . . . . . . . . . . . . . . . .9A XLWL-G . . . . . . . . . . . . . . . . .9A XNP (Special) . . . . . . . . . . . . .9A XPB2-18320L1 . . . . . . . . . . . .8A XLSA-GH . . . . . . . . . . . . . . . .9A XLWS . . . . . . . . . . . . . . . . . . .9A XNP (Standard) . . . . . . . . . . . .9A XPB2-183L1 . . . . . . . . . . . . . .8A XLSAH . . . . . . . . . . . . . . . . . .9A XLWS-G . . . . . . . . . . . . . . . . .9A XNPWB . . . . . . . . . . . . . . . . .9A XPB2-2 . . . . . . . . . . . . . . . . . .8A XLSAL-GH . . . . . . . . . . . . . . . .9A XLWS-GH . . . . . . . . . . . . . . . .9A XNPWG . . . . . . . . . . . . . . . . .9A XPB2-24320B1 . . . . . . . . . . . .8A XLSAS . . . . . . . . . . . . . . . . . .9A XMB . . . . . . . . . . . . . . . . . . . .9A XNPWR . . . . . . . . . . . . . . . . .9A XPB2-24320L1 . . . . . . . . . . . .8A XLSAS-G . . . . . . . . . . . . . . . . .9A XMC . . . . . . . . . . . . . . . . . . . .9A XPB1-1 . . . . . . . . . . . . . . . . . .8A XPB2-24320L2 . . . . . . . . . . . .8A XLSAS-GH . . . . . . . . . . . . . . .9A XMMSA1 . . . . . . . . . . . . . . . .8C XPB1-121 . . . . . . . . . . . . . . . .8A XPB2-243L1 . . . . . . . . . . . . . .8A XLSB . . . . . . . . . . . . . . . . . . .9A XMMSA2 . . . . . . . . . . . . . . . .8C XPB1-121B1 . . . . . . . . . . . . . .8A XPB2-243L2 . . . . . . . . . . . . . .8A XLSB-G . . . . . . . . . . . . . . . . . .9A XMNP . . . . . . . . . . . . . . . . . . .9A XPB1-121L1 . . . . . . . . . . . . . .8A XPB2-3 . . . . . . . . . . . . . . . . . .8A XLSB-GH . . . . . . . . . . . . . . . .9A XMOB-1 . . . . . . . . . . . . . . . . .9A XPB1-121L2 . . . . . . . . . . . . . .8A XPB2-303L2 . . . . . . . . . . . . . .8A XLSBL-GH . . . . . . . . . . . . . . . .9A XMOB-2 . . . . . . . . . . . . . . . . .9A XPB1-123 . . . . . . . . . . . . . . . .8A XPB2-363L2 . . . . . . . . . . . . . .8A XLSBS . . . . . . . . . . . . . . . . . .9A XMOB-3 . . . . . . . . . . . . . . . . .9A XPB1-123B1 . . . . . . . . . . . . . .8A XPB2-H1 . . . . . . . . . . . . . . . . .8A XLSBS-G . . . . . . . . . . . . . . . . .9A XMOB-4 . . . . . . . . . . . . . . . . .9A XPB1-123L1 . . . . . . . . . . . . . .8A XPO . . . . . . . . . . . . . . . . . . . .9A XLSBS-GH . . . . . . . . . . . . . . .9A XMOBS-1 . . . . . . . . . . . . . . . .9A XPB1-181 . . . . . . . . . . . . . . . .8A XPOC . . . . . . . . . . . . . . . . . . .9A XLSC . . . . . . . . . . . . . . . . . . .9A XMOBS-2 . . . . . . . . . . . . . . . .9A XPB1-181B1 . . . . . . . . . . . . . .8A XPOCH . . . . . . . . . . . . . . . . . .9A XLSC 2 LESS SWITCH . . . . . .8C XMOBS-3 . . . . . . . . . . . . . . . .9A XPB1-181L1 . . . . . . . . . . . . . .8A XPOCS . . . . . . . . . . . . . . . . . .9A XLSC 3 LESS SWITCH . . . . . .8C XMOBS-4 . . . . . . . . . . . . . . . .9A XPB1-183 . . . . . . . . . . . . . . . .8A XPOCSH . . . . . . . . . . . . . . . . .9A XLSC21 . . . . . . . . . . . . . . . . . .8C XMOLA . . . . . . . . . . . . . . . . . .9A XPB1-183B1 . . . . . . . . . . . . . .8A XPOH . . . . . . . . . . . . . . . . . . .9A XLSC22 . . . . . . . . . . . . . . . . . .8C XMOLG . . . . . . . . . . . . . . . . .9A XPB1-183L1 . . . . . . . . . . . . . .8A XPOS . . . . . . . . . . . . . . . . . . .9A XLSC31 . . . . . . . . . . . . . . . . . .8C XMOLR . . . . . . . . . . . . . . . . . .9A XPB1-2 . . . . . . . . . . . . . . . . . .8A XPOSH . . . . . . . . . . . . . . . . . .9A XLSC32 . . . . . . . . . . . . . . . . . .8C XMOS-1 . . . . . . . . . . . . . . . . .9A XPB1-2411 . . . . . . . . . . . . . . .8A XPP . . . . . . . . . . . . . . . . . . . . .9A XLSC-G . . . . . . . . . . . . . . . . . .9A XMOS-2 . . . . . . . . . . . . . . . . .9A XPB1-2412 . . . . . . . . . . . . . . .8A XPPH . . . . . . . . . . . . . . . . . . .9A XLSC-GH . . . . . . . . . . . . . . . .9A XMOS-3 . . . . . . . . . . . . . . . . .9A XPB1-24120B1 . . . . . . . . . . . .8A XPP-N4 . . . . . . . . . . . . . . . . . .9A XLSCS . . . . . . . . . . . . . . . . . .9A XMOSS-1 . . . . . . . . . . . . . . . .9A XPB1-24120L1 . . . . . . . . . . . .8A XRB . . . . . . . . . . . . . . . . . . . .9A XLSCS-G . . . . . . . . . . . . . . . . .9A XMOSS-2 . . . . . . . . . . . . . . . .9A XPB1-24120L2 . . . . . . . . . . . .8A XRBH . . . . . . . . . . . . . . . . . . .9A XLSCS-GH . . . . . . . . . . . . . . .9A XMOSS-3 . . . . . . . . . . . . . . . .9A XPB1-2431 . . . . . . . . . . . . . . .8A XRBL . . . . . . . . . . . . . . . . . . .9A XLSG . . . . . . . . . . . . . . . . . . .9A XMPP . . . . . . . . . . . . . . . . . . .9A XPB1-2432 . . . . . . . . . . . . . . .8A XRBLH . . . . . . . . . . . . . . . . . .9A XLSG-G . . . . . . . . . . . . . . . . . .9A XMRSC 60 . . . . . . . . . . . . . . .8C XPB1-24320B1 . . . . . . . . . . . .8A XSB 0303 . . . . . . . . . . . . . . . .5A XLSG-GH . . . . . . . . . . . . . . . .9A XMRSC 61 . . . . . . . . . . . . . . .8C XPB1-24320L1 . . . . . . . . . . . .8A XSB 0306 . . . . . . . . . . . . . . . .5A XLSGL-GH . . . . . . . . . . . . . . .9A XMRSC-N4 . . . . . . . . . . . . . . .8C XPB1-24320L2 . . . . . . . . . . . .8A XSB 0307 . . . . . . . . . . . . . . . .5A XLSGS . . . . . . . . . . . . . . . . . .9A XMRSF 62 . . . . . . . . . . . . . . .8C XPB1-3 . . . . . . . . . . . . . . . . . .8A XSB 0309 . . . . . . . . . . . . . . . .5A XLSGS-G . . . . . . . . . . . . . . . . .9A XMRSF-N4 . . . . . . . . . . . . . . .8C XPB1-3012 . . . . . . . . . . . . . . .8A XSB 0311 . . . . . . . . . . . . . . . .5A XLSGS-GH . . . . . . . . . . . . . . .9A XMRSO 63 . . . . . . . . . . . . . . .8C XPB1-3032 . . . . . . . . . . . . . . .8A XSB 0313 . . . . . . . . . . . . . . . .5A XLSR . . . . . . . . . . . . . . . . . . .9A XMRSO 64 . . . . . . . . . . . . . . .8C XPB1-30320L2 . . . . . . . . . . . .8A XSB 0315 . . . . . . . . . . . . . . . .5A XLSR-G . . . . . . . . . . . . . . . . . .9A XMRSO-N4 . . . . . . . . . . . . . . .8C XPB1-3612 . . . . . . . . . . . . . . .8A XSB 0318 . . . . . . . . . . . . . . . .5A XLSR-GH . . . . . . . . . . . . . . . .9A XMSB 60 . . . . . . . . . . . . . . . .8C XPB1-3632 . . . . . . . . . . . . . . .8A XSB 0324 . . . . . . . . . . . . . . . .5A XLSRL-GH . . . . . . . . . . . . . . . .9A XMSB 61 . . . . . . . . . . . . . . . .8C XPB1-36320L2 . . . . . . . . . . . .8A XSB 0330 . . . . . . . . . . . . . . . .5A XLSRS . . . . . . . . . . . . . . . . . .9A XMSB N4 . . . . . . . . . . . . . . . .8C XPB1-G1 . . . . . . . . . . . . . . . . .8A XSB 0336 . . . . . . . . . . . . . . . .5A XLSRS-G . . . . . . . . . . . . . . . . .9A XMSB-N4 . . . . . . . . . . . . . . . .8C XPB1-G2 . . . . . . . . . . . . . . . . .8A XSB 0406 . . . . . . . . . . . . . . . .5A XLSRS-GH . . . . . . . . . . . . . . .9A XMSD 62 . . . . . . . . . . . . . . . .8C XPB1-H1 . . . . . . . . . . . . . . . . .8A XSB 0412 . . . . . . . . . . . . . . . .5A XLSW . . . . . . . . . . . . . . . . . . .9A XMSD N4 . . . . . . . . . . . . . . . .8C XPB1-H2 . . . . . . . . . . . . . . . . .8A XSB 0416 . . . . . . . . . . . . . . . .5A XLSWL-GH . . . . . . . . . . . . . . .9A XMSD-N4 . . . . . . . . . . . . . . . .8C XPB1-N1 . . . . . . . . . . . . . . . . .8A XSB 0606 . . . . . . . . . . . . . . . .5A 376 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 5:28 PM Page 377 Index Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section Catalog Number Catalog Section XSB 0608 . . . . . . . . . . . . . . . .5A XSIAH12 . . . . . . . . . . . . . . . . .8D XSM 0718 . . . . . . . . . . . . . . . .5A XVHPPMS . . . . . . . . . . . . . . . .9A XSB 0611 . . . . . . . . . . . . . . . .5A XSIAH18 . . . . . . . . . . . . . . . . .8D XSM 0808 . . . . . . . . . . . . . . . .5A XVHSS . . . . . . . . . . . . . . . . . .9A XSB 0612 . . . . . . . . . . . . . . . .5A XSIAH25 . . . . . . . . . . . . . . . . .8D XSM 0810 . . . . . . . . . . . . . . . .5A XVHSSPL . . . . . . . . . . . . . . . .9A XSB 0613 . . . . . . . . . . . . . . . .5A XSIAS . . . . . . . . . . . . . . . . . . .8D XSM 0812 . . . . . . . . . . . . . . . .5A XVHSSS . . . . . . . . . . . . . . . . .9A XSB 0618 . . . . . . . . . . . . . . . .5A XSIAS12 . . . . . . . . . . . . . . . . .8D XSM 0911 . . . . . . . . . . . . . . . .5A XVHSSSPL . . . . . . . . . . . . . . .9A XSB 0624 . . . . . . . . . . . . . . . .5A XSIAS17 . . . . . . . . . . . . . . . . .8D XSM 1010 . . . . . . . . . . . . . . . .5A XVPO . . . . . . . . . . . . . . . . . . .9A XSB 0636 . . . . . . . . . . . . . . . .5A XSIAS25 . . . . . . . . . . . . . . . . .8D XSM 1014 . . . . . . . . . . . . . . . .5A XVPOC . . . . . . . . . . . . . . . . . .9A XSB 0707 . . . . . . . . . . . . . . . .5A XSIAS9 . . . . . . . . . . . . . . . . . .8D XSM 1212 . . . . . . . . . . . . . . . .5A XVPOCS . . . . . . . . . . . . . . . . .9A XSB 0710 . . . . . . . . . . . . . . . .5A XSIBD . . . . . . . . . . . . . . . . . . .8D XSM 1218 . . . . . . . . . . . . . . . .5A XVPOS . . . . . . . . . . . . . . . . . .9A XSB 0716 . . . . . . . . . . . . . . . .5A XSIBD25 . . . . . . . . . . . . . . . . .8D XSM 1220 . . . . . . . . . . . . . . . .5A XVS 4 . . . . . . . . . . . . . . . . . . .5D XSB 0718 . . . . . . . . . . . . . . . .5A XSIBD32 . . . . . . . . . . . . . . . . .8D XSM 1224 . . . . . . . . . . . . . . . .5A XVS 5 . . . . . . . . . . . . . . . . . . .5D XSB 0808 . . . . . . . . . . . . . . . .5A XSICA . . . . . . . . . . . . . . . . . . .8D XSM 1230 . . . . . . . . . . . . . . . .5A XVS 6 . . . . . . . . . . . . . . . . . . .5D XSB 0810 . . . . . . . . . . . . . . . .5A XSICA28 . . . . . . . . . . . . . . . . .8D XSM 1236 . . . . . . . . . . . . . . . .5A XVS 8 . . . . . . . . . . . . . . . . . . .5D XSB 0812 . . . . . . . . . . . . . . . .5A XSICA32 . . . . . . . . . . . . . . . . .8D XSM 1246 . . . . . . . . . . . . . . . .5A XY 2 . . . . . . . . . . . . . . . . . . .10A XSB 0832 . . . . . . . . . . . . . . . .5A XSICA41 . . . . . . . . . . . . . . . . .8D XSM 1414 . . . . . . . . . . . . . . . .5A XY 3 . . . . . . . . . . . . . . . . . . .10A XSB 0911 . . . . . . . . . . . . . . . .5A XSICA54 . . . . . . . . . . . . . . . . .8D XSM 1422 . . . . . . . . . . . . . . . .5A XY 34 . . . . . . . . . . . . . . . . . .10A XSB 1010 . . . . . . . . . . . . . . . .5A XSICD . . . . . . . . . . . . . . . . . . .8D XSM 1428 . . . . . . . . . . . . . . . .5A XY 4 . . . . . . . . . . . . . . . . . . .10A XSB 1014 . . . . . . . . . . . . . . . .5A XSICD37 . . . . . . . . . . . . . . . . .8D XSM 1616 . . . . . . . . . . . . . . . .5A XY 44 . . . . . . . . . . . . . . . . . .10A XSB 1212 . . . . . . . . . . . . . . . .5A XSICD40 . . . . . . . . . . . . . . . . .8D XSM 1624 . . . . . . . . . . . . . . . .5A XY 5 . . . . . . . . . . . . . . . . . . .10A XSB 1218 . . . . . . . . . . . . . . . .5A XSICD50 . . . . . . . . . . . . . . . . .8D XSM 1630 . . . . . . . . . . . . . . . .5A XY 54 . . . . . . . . . . . . . . . . . .10A XSB 1220 . . . . . . . . . . . . . . . .5A XSICH . . . . . . . . . . . . . . . . . . .8D XSM 1646 . . . . . . . . . . . . . . . .5A XY 6 . . . . . . . . . . . . . . . . . . .10A XSB 1224 . . . . . . . . . . . . . . . .5A XSICH32 . . . . . . . . . . . . . . . . .8D XSM 1818 . . . . . . . . . . . . . . . .5A XYB 10 . . . . . . . . . . . . . . . . .10A XSB 1230 . . . . . . . . . . . . . . . .5A XSICH37 . . . . . . . . . . . . . . . . .8D XSM 1824 . . . . . . . . . . . . . . . .5A XYB 104 . . . . . . . . . . . . . . . .10A XSB 1236 . . . . . . . . . . . . . . . .5A XSICH44 . . . . . . . . . . . . . . . . .8D XSM 1830 . . . . . . . . . . . . . . . .5A XYB 12 . . . . . . . . . . . . . . . . .10A XSB 1246 . . . . . . . . . . . . . . . .5A XSICH60 . . . . . . . . . . . . . . . . .8D XSM 1836 . . . . . . . . . . . . . . . .5A XYB 124 . . . . . . . . . . . . . . . .10A XSB 1414 . . . . . . . . . . . . . . . .5A XSICS . . . . . . . . . . . . . . . . . . .8D XSM 2424 . . . . . . . . . . . . . . . .5A XYB 14 . . . . . . . . . . . . . . . . .10A XSB 1428 . . . . . . . . . . . . . . . .5A XSICS28 . . . . . . . . . . . . . . . . .8D XSM 2430 . . . . . . . . . . . . . . . .5A XYB 144 . . . . . . . . . . . . . . . .10A XSB 1616 . . . . . . . . . . . . . . . .5A XSICS32 . . . . . . . . . . . . . . . . .8D XSM 2436 . . . . . . . . . . . . . . . .5A XYB 16 . . . . . . . . . . . . . . . . .10A XSB 1624 . . . . . . . . . . . . . . . .5A XSICS40 . . . . . . . . . . . . . . . . .8D XSO 663 B . . . . . . . . . . . . . . .5E XYB 164 . . . . . . . . . . . . . . . .10A XSB 1646 . . . . . . . . . . . . . . . .5A XSICS50 . . . . . . . . . . . . . . . . .8D XSO 663 S . . . . . . . . . . . . . . .5E XYB 2 . . . . . . . . . . . . . . . . . .10A XSB 1818 . . . . . . . . . . . . . . . .5A XSIDA . . . . . . . . . . . . . . . . . . .8D XSO 884 . . . . . . . . . . . . . . . . .5E XYB 3 . . . . . . . . . . . . . . . . . .10A XSB 1824 . . . . . . . . . . . . . . . .5A XSIDA65 . . . . . . . . . . . . . . . . .8D XSO 884 S . . . . . . . . . . . . . . .5E XYB 34 . . . . . . . . . . . . . . . . .10A XSB 1830 . . . . . . . . . . . . . . . .5A XSIDA80 . . . . . . . . . . . . . . . . .8D XSO 885 . . . . . . . . . . . . . . . . .5E XYB 4 . . . . . . . . . . . . . . . . . .10A XSB 1836 . . . . . . . . . . . . . . . .5A XSIDD . . . . . . . . . . . . . . . . . . .8D XSSL 4P . . . . . . . . . . . . . . . . .9A XYB 44 . . . . . . . . . . . . . . . . .10A XSB 2424 . . . . . . . . . . . . . . . .5A XSIDD65 . . . . . . . . . . . . . . . . .8D XSSL 5P . . . . . . . . . . . . . . . . .9A XYB 5 . . . . . . . . . . . . . . . . . .10A XSB 2430 . . . . . . . . . . . . . . . .5A XSIDD80 . . . . . . . . . . . . . . . . .8D XSSS 4P . . . . . . . . . . . . . . . . .9A XYB 54 . . . . . . . . . . . . . . . . .10A XSB 2436 . . . . . . . . . . . . . . . .5A XSIDH . . . . . . . . . . . . . . . . . . .8D XSSS 5P . . . . . . . . . . . . . . . . .9A XYB 6 . . . . . . . . . . . . . . . . . .10A XSC 16 . . . . . . . . . . . . . . . . .10A XSIDH73 . . . . . . . . . . . . . . . . .8D XU 2 . . . . . . . . . . . . . . . . . . .10A XYB 8 . . . . . . . . . . . . . . . . . .10A XSC 160 . . . . . . . . . . . . . . . .10A XSIDS . . . . . . . . . . . . . . . . . . .8D XU 3 . . . . . . . . . . . . . . . . . . .10A XYB 84 . . . . . . . . . . . . . . . . .10A XSC 8 . . . . . . . . . . . . . . . . . .10A XSIDS65 . . . . . . . . . . . . . . . . .8D XU 4 . . . . . . . . . . . . . . . . . . .10A XYBM 10 . . . . . . . . . . . . . . .10A XSIAA . . . . . . . . . . . . . . . . . . .8D XSIDS80 . . . . . . . . . . . . . . . . .8D XUM 2 . . . . . . . . . . . . . . . . .10A XYBM 104 . . . . . . . . . . . . . .10A XSIAA11 . . . . . . . . . . . . . . . . .8D XSIDS95 . . . . . . . . . . . . . . . . .8D XUM 3 . . . . . . . . . . . . . . . . .10A XYBM 12 . . . . . . . . . . . . . . .10A XSIAA25 . . . . . . . . . . . . . . . . .8D XSIEA . . . . . . . . . . . . . . . . . . .8D XUM 4 . . . . . . . . . . . . . . . . .10A XYBM 124 . . . . . . . . . . . . . .10A XSIAA9 . . . . . . . . . . . . . . . . . .8D XSIEA110 . . . . . . . . . . . . . . . .8D XVHKSS . . . . . . . . . . . . . . . . .9A XYBM 14 . . . . . . . . . . . . . . .10A XSIAD . . . . . . . . . . . . . . . . . . .8D XSM 0416 . . . . . . . . . . . . . . . .5A XVHKSSS . . . . . . . . . . . . . . . .9A XYBM 144 . . . . . . . . . . . . . .10A XSIAD12 . . . . . . . . . . . . . . . . .8D XSM 0608 . . . . . . . . . . . . . . . .5A XVHPB . . . . . . . . . . . . . . . . . .9A XYBM 16 . . . . . . . . . . . . . . .10A XSIAD18 . . . . . . . . . . . . . . . . .8D XSM 0611 . . . . . . . . . . . . . . . .5A XVHPBM . . . . . . . . . . . . . . . .9A XYBM 164 . . . . . . . . . . . . . .10A XSIAD9 . . . . . . . . . . . . . . . . . .8D XSM 0612 . . . . . . . . . . . . . . . .5A XVHPBMS . . . . . . . . . . . . . . .9A XYBM 2 . . . . . . . . . . . . . . . .10A XSIAH . . . . . . . . . . . . . . . . . . .8D XSM 0613 . . . . . . . . . . . . . . . .5A XVHPBS . . . . . . . . . . . . . . . . .9A XYBM 3 . . . . . . . . . . . . . . . .10A XSIAH10 . . . . . . . . . . . . . . . . .8D XSM 0710 . . . . . . . . . . . . . . . .5A XVHPPM . . . . . . . . . . . . . . . . .9A XYBM 34 . . . . . . . . . . . . . . .10A 377 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com INDEX Catalog Number 15599 Index 12/11/01 5:57 PM Page 378 Index Catalog Number Catalog Section Catalog Number Catalog Section XYBM 4 . . . . . . . . . . . . . . . .10A XYC 34 SM . . . . . . . . . . . . . .10A XYBM 44 . . . . . . . . . . . . . . .10A XYC 4 . . . . . . . . . . . . . . . . . .10A XYBM 5 . . . . . . . . . . . . . . . .10A XYC 4 M . . . . . . . . . . . . . . . .10A XYBM 54 . . . . . . . . . . . . . . .10A XYC 4 S . . . . . . . . . . . . . . . .10A XYBM 6 . . . . . . . . . . . . . . . .10A XYC 4 SM . . . . . . . . . . . . . . .10A XYBM 8 . . . . . . . . . . . . . . . .10A XYC 44 . . . . . . . . . . . . . . . . .10A XYBM 84 . . . . . . . . . . . . . . .10A XYC 44 M . . . . . . . . . . . . . . .10A XYC 10 . . . . . . . . . . . . . . . . .10A XYC 44 S . . . . . . . . . . . . . . .10A XYC 10 M . . . . . . . . . . . . . . .10A XYC 44 SM . . . . . . . . . . . . . .10A XYC 10 S . . . . . . . . . . . . . . .10A XYC 5 . . . . . . . . . . . . . . . . . .10A XYC 10 SM . . . . . . . . . . . . . .10A XYC 5 M . . . . . . . . . . . . . . . .10A XYC 104 . . . . . . . . . . . . . . . .10A XYC 5 S . . . . . . . . . . . . . . . .10A XYC 104 M . . . . . . . . . . . . . .10A XYC 5 SM . . . . . . . . . . . . . . .10A XYC 104 S . . . . . . . . . . . . . .10A XYC 54 . . . . . . . . . . . . . . . . .10A XYC 104 SM . . . . . . . . . . . . .10A XYC 54 M . . . . . . . . . . . . . . .10A XYC 12 . . . . . . . . . . . . . . . . .10A XYC 54 S . . . . . . . . . . . . . . .10A XYC 12 M . . . . . . . . . . . . . . .10A XYC 54 SM . . . . . . . . . . . . . .10A XYC 12 S . . . . . . . . . . . . . . .10A XYC 6 . . . . . . . . . . . . . . . . . .10A XYC 12 SM . . . . . . . . . . . . . .10A XYC 6 M . . . . . . . . . . . . . . . .10A XYC 124 . . . . . . . . . . . . . . . .10A XYC 6 S . . . . . . . . . . . . . . . .10A XYC 124 M . . . . . . . . . . . . . .10A XYC 6 SM . . . . . . . . . . . . . . .10A XYC 124 S . . . . . . . . . . . . . .10A XYC 8 . . . . . . . . . . . . . . . . . .10A XYC 124 SM . . . . . . . . . . . . .10A XYC 8 M . . . . . . . . . . . . . . . .10A XYC 14 . . . . . . . . . . . . . . . . .10A XYC 8 S . . . . . . . . . . . . . . . .10A XYC 14 M . . . . . . . . . . . . . . .10A XYC 8 SM . . . . . . . . . . . . . . .10A XYC 14 S . . . . . . . . . . . . . . .10A XYC 84 . . . . . . . . . . . . . . . . .10A XYC 14 SM . . . . . . . . . . . . . .10A XYC 84 M . . . . . . . . . . . . . . .10A XYC 144 . . . . . . . . . . . . . . . .10A XYC 84 S . . . . . . . . . . . . . . .10A XYC 144 M . . . . . . . . . . . . . .10A XYC 84 SM . . . . . . . . . . . . . .10A XYC 144 S . . . . . . . . . . . . . .10A XYM 2 . . . . . . . . . . . . . . . . . .10A XYC 144 SM . . . . . . . . . . . . .10A XYM 3 . . . . . . . . . . . . . . . . . .10A XYC 16 . . . . . . . . . . . . . . . . .10A XYM 4 . . . . . . . . . . . . . . . . . .10A XYC 16 M . . . . . . . . . . . . . . .10A XYM 5 . . . . . . . . . . . . . . . . . .10A XYC 16 S . . . . . . . . . . . . . . .10A XYM 6 . . . . . . . . . . . . . . . . . .10A XYC 16 SM . . . . . . . . . . . . . .10A Z-1010 . . . . . . . . . . . . . . . . . .1C XYC 164 . . . . . . . . . . . . . . . .10A Z-1011-L . . . . . . . . . . . . . . . . .1C XYC 164 M . . . . . . . . . . . . . .10A Z-1011-R . . . . . . . . . . . . . . . . .1C XYC 164 S . . . . . . . . . . . . . .10A Z-2011 . . . . . . . . . . . . . . . . . .1C XYC 164 SM . . . . . . . . . . . . .10A Z-2033 . . . . . . . . . . . . . . . . . .1C XYC 2 . . . . . . . . . . . . . . . . . .10A Z-2034 . . . . . . . . . . . . . . . . . .1C XYC 2 M . . . . . . . . . . . . . . . .10A XYC 2 S . . . . . . . . . . . . . . . .10A XYC 2 SM . . . . . . . . . . . . . . .10A XYC 3 . . . . . . . . . . . . . . . . . .10A XYC 3 M . . . . . . . . . . . . . . . .10A XYC 3 S . . . . . . . . . . . . . . . .10A XYC 3 SM . . . . . . . . . . . . . . .10A XYC 34 . . . . . . . . . . . . . . . . .10A XYC 34 M . . . . . . . . . . . . . . .10A INDEX XYC 34 S . . . . . . . . . . . . . . .10A 378 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 6:12 PM Page 379 379 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com NOTES Notes 15599 Index 12/10/01 6:12 PM Page 380 Notes NOTES 380 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 6:12 PM Page 381 381 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com NOTES Notes 15599 Index 12/10/01 6:12 PM Page 382 Notes NOTES 382 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 15599 Index 12/10/01 6:12 PM Page 383 383 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com NOTES Notes 15599 Index 12/10/01 6:12 PM Page 384 Notes NOTES 384 ADALET Enclosure Systems • Designing Our Products Around Yours SM T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com 14743 CB whole catalog 12/2/00 1:01 PM Page 2 For The Latest Product Developments... Visit www.adalet.com • Complete Adalet catalog as Acrobat® PDF downloadable files • New! Circuit Breaker Lighting & Power Distribution Panelboards brochure as PDF file Adalet Adalet, a division of Scott Fetzer, is a leading manufacturer of enclosure systems and cable accessories. From relay, meter, instrument and junction boxes to control enclosures suitable for NEMA Type 1 through Type 13 applications, motor starters, control stations and power panels, our enclosures provide cost-effective solutions to a variety of industry needs. The Adalet line of cable accessories serves the construction, mining and utility markets with fittings, couplers, splices and terminations for metal clad, paper insulated lead and solid dielectric applications from 600V to 35KV. To find out more about Adalet products, engineering services and our company-wide commitment to quality, just give us a call. Mission Statement “We are a customer-driven, growth-oriented company which designs and manufactures engineered enclosures, fittings, cable accessories and related electrical products for industry.” www.adalet.com The information in this catalog is compiled from data which we believe is reliable and is given in good faith. Since the methods of application and conditions under which our products are used are beyond our control, we are not able to guarantee the application and/or use of same. The user assumes all risks and liability in connection with the application and use of our products. Adalet is not responsible for typographical, illustrative or photographic errors that may appear in this catalog. Adalet reserves the right to make adjustments or corrections due to errors, changing market conditions, product discontinuations or typographical, illustrative or photographic errors. Metric units are provided for reference only. Specifications subject to change without prior notice. Contact Adalet for the most current specifications for specific products. A S C OT T F E T Z E R C O M PA N Y Enclosure Systems • Cable Accessories 4801 West 150th Street • Cleveland, Ohio 44135 • phone 216.267.9000 • fax 216.267.1681 • info@adalet.com • www.adalet.com © 2001 Adalet Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2002:01:18 14:37:47Z Modify Date : 2009:12:11 18:13:24-08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Metadata Date : 2009:12:11 18:13:24-08:00 Producer : Acrobat Distiller 4.05 for Macintosh Format : application/pdf Document ID : uuid:7f7b0333-2dd0-f649-8db1-8ee1e3ea987d Instance ID : uuid:b554fc2e-bd92-4a49-b8f8-3694bf4201c0 Page Count : 388EXIF Metadata provided by EXIF.tools