496 51 5502 02 4/14/15
Specifications are subject to change without notice.
E
N
V
I
R
O
N
M
E
N
T
A
L
L
Y
S
O
U
N
D
R
E
F
R
I
G
E
R
A
N
T
FAN COILS
ALL MODELS
S11/2 thru 4 tons
SAvailable for environmentally sound R410A systems
SFactory installed piston metering device with Teflon ring
SSweat connections
SAluminum Tube, Aluminum Fin Evaporator
SPrimary and secondary drain fittings with brass inserts
SMultiple electrical entry locations
STime delay relay (TDR)
SField installed heater packages from 5 kW 30 kW available
separately
SHUD approved for manufactured housing
S208/230160 supply voltage
SUnits tested and certified by manufacturer to achieve a 2% or
less leakage rate at 1.0 inch water column
S1 inch thick insulation with R value of 4.2
SMultiposition installation upflow or horizontal left standard,
horizontal right with minor modification (field convertible to
downflow with available accessory kit)
SNo Heat (Plug) Kit factory installed
SFilter (washable) available as accessory
FEM4P
SECM 5speed motor
SLow voltage circuit protective fuse (3amp) inline on wire harness
FSM4P
SPSC 2speed motor
SPrinted circuit board (PCB) with low voltage circuit protective
fuse (5 amp)
WARRANTY*
FEM
S1 year No Hassle Replacementt limited warranty
FEM, FSM
S5 year parts limited warranty
With timely registration, an additional 5 year parts limited
warranty
Available Styles FEM4P FSM4P
Upflow 3 3
Horizontal 3 3
Downflow kit kit
Motor ECM PSC
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org .
*For residential applications only. See warranty certificate for complete details and
restrictions, including warranty coverage for other applications.
Model Number Tons
Nom.
CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm)
Ship Wt
lbs. (kg)
FEM4P1800AL 11/2 600 (283) 4211/16 x 145/16 x 221/16 (1084 x 364 x 560) 13 x 211/2 (330 x 546) 112 (51)
FSM4P1800AL 475/8 x 175/8 x 221/16 (1210 x 448 x 560) 13 x 211/2 (330 x 546) 117 (51)
FEM4P2400AL 2800 (378) 4211/16 x 145/16 x 221/16 (1084 x 364 x 560) 13 x 211/2 (330 x 546) 112 (51)
FSM4P2400AL 495/8 x 175/8 x 221/16 (1261 x 448 x 560) 163/8 x 211/2 (416 x 546) 128 (58)
FEM4P3000AL 21/2 1000 (472) 495/8 x 175/8 x 221/16 (1261 x 448 x 560) 163/8 x 211/2 (416 x 546) 122 (55)
FSM4P3000AL 537/16 x 211/8 x 221/16 (1357 x 537 x 560) 197/8 x 211/2 (505 x 546) 145 (66)
FEM4P3600AL 31200 (566) 495/8 x 175/8 x 221/16 (1261 x 448 x 560) 163/8 x 211/2 (416 x 546) 122 (55)
FSM4P3600AL 537/16 x 211/8 x 221/16 (1357 x 537 x 560) 197/8 x 211/2 (505 x 546) 148 (67)
FEM4P4200AL 3-1/2 1400 (661) 495/8 x 211/8 x 221/16 (1261 x 537 x 560) 197/8 x 211/2 (505 x 546) 157 (71)
FSM4P4200AL 156 (71)
FEM4P4800AL 41600 (755) 495/8 x 211/8 x 221/16 (1261 x 537 x 560) 197/8 x 211/2 (505 x 546) 157 (71)
FSM4P4800AL 537/16 x 2411//16 x 221/16 (1357 x 627 x 560) 235/16 x 211/2 (592 x 546) 182 (83)
®
FEM4P, FSM4P
Product Specifications
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
2496 51 5502 02
Specifications are subject to change without notice.
FAN COIL MODEL NUMBER IDENTIFICATION GUIDE
F E M 4 P 1800 A L
F = Fan Coil
S = Standard PSC
E = ECM 5Speed MOTOR TYPE
U = Upflow
M = Multiposition INSTALLATION TYPE
4 = Environmentally Sound R410A REFRIGERANT
P = Piston Metering Device METERING DEVICE
1800 = 18,000 BTUH = 11/2 tons
2400 = 24,000 BTUH = 2 tons
3000 = 30,000 BTUH = 21/2 tons
3600 = 36,000 BTUH = 3 tons
4200 = 42,000 BTUH = 31/2 tons
4800 = 48,000 BTUH = 4 tons NOMINAL CAPACITY
A = Copper Tubes, Aluminum Fin Evaporator Coil
AL = Aluminum Tubes, Aluminum Fin Evaporator Coil
AT = Tin Coated Copper Tubes, Aluminum Fin Evaporator Coil SALES CODE / FEATURES
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
EB AC 01 NCB A
EB = Evaporator Blower
AC = Accessory
01 = Product Identifier Number
NCB = NonCombustible Base Kit
DFK = Down Flow Kit
PLG = Power Plug (no heat kit)
SPK = Single Point Wiring Kit
FKS = Filter Kit Small
FKM = Filter Kit Medium
FKL = Filter Kit Large
FKX = Filter Kit Extra Large
CTK = Condensate Trap Kit (PVC pipe)
Sales Code
ELECTRIC HEATER MODEL NUMBER IDENTIFICATION GUIDE
EHK 05 A K N 1
EHK = Electric Heater Kit
05 = 5 kW
07 = 7 kW
09 = 9 kW
10 = 10 kW
15 = 15 kW
18 = 18 kW
20 = 20 kW
25 = 25 kW
30 = 30 kW NOMINAL HEAT VALUE
Sales Code
K = 208 / 230 singlephase
H = 208 / 230, 3phase
KC = 208 / 230, supplied as single phase, field convertible to 3phase
HC = 208 / 230 supplied as 3phase, field convertible to single phase VOLTAGE (60 Hz)
Product Identifier
Engineering Code
Dimensions English (Inches)SD48954_A
10 3/4”
6 3/16”
2 5/8”
1 1/
2
1 7/8”
3 1/16”
4 11/16”
1”
10 3/16” 3/4”
22 1/16”
1 3/8”
1 15/16”
OPENING
19 13/16”
2 1/8”
1” 1 1/4”
A
15/16”
1 3/16”
E
1”
5” D
9 1/2”
7/8”11”
1 3/4”
19”
COIL ACCESS
PANEL
LIQUID LINE CONNECTION
SUCTION LINE CONNECTION
FILTER ACCESS
PANEL
FITTING
PANEL
B
C
ACCESS PANEL CONFIG. FOR
SLOPE COILS
DOWNFLOW OR HORIZ.
RIGHT APPLICATIONS
AND
”A” COILS
DOWNFLOW APPLICATIONS
TOP VIEW
LIQUID LINE
CONNECTION
LIQUID LINE
CONNECTION
SUCTION LINE
CONNECTION
FRONT VIEW
SLOPE COIL DETAILS
CONNECTION LOCATIONS SHOWN
FOR UPFLOW OR HORIZ.
LEFT APPLICATIONS
OPTIONAL FIELD CONVERTED
RIGHT SIDE RETURN OPENING
(SLOPE COIL UNITS ONLY)
FOR LOW VOLTAGE
CONTROL WIRING
ALTERNATE
7/8”,1 3/32”,2”DIA.
FOR HIGH VOLTAGE
POWER WIRING
OPPOSITE SIDE
INLET AIR
INLET AIR
INLET AIR
OUTLET AIR
7/8”DIA. K.O.
FOR LOW VOLTAGE
CONTROL WIRING
7/8”, 1 3/32”
2” DIA. K.O.’S
FOR HIGH VOLTAGE
POWER WIRING
OPENING
H
J
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
496 51 5502 02 3
Specifications are subject to change without notice.
UNIT CONNECTION SIZES
SUCTION:
FEM4P: 18 and 24 — 5/8” I.D. SWEAT
30 and 36 — 3/4” I.D. SWEAT
42 and 48 — 7/8” I.D. SWEAT
FSM4P: 18, 24, 30, 36 — 3/4” I.D. SWEAT
42 and 48 — 7/8” I.D. SWEAT
LIQUID: 3/8” I.D. SWEAT
CONDENSATE: 3/4” FPT
Horizontal Left
FEM4P, FSM4P (as shipped)
Upflow
(as shipped) Downflow
(field converted with accessory kits) Horizontal Right
FEM4P, FSM4P (field converted with accessory kits)
7 7/8” 1 3/16”
1 1/2”
1/2”
TYP.*
7 7/8”
1 3/16”
1 1/2”
1 1/4”
3 1/4”
1 5/8” 3 1/4”
2 9/16”
2 7/8”
1” TYP.
(2 PLACES)*
7/16” TYP.
2 3/16”
TYP.
2 3/16”
TYP.
(2 PLACES)*
1” TYP.
(2 PLACES)
7/16” TYP.
(2 PLACES)*
1” TYP.
(2 PLACES)*
7/16” TYP.
(4 PLACES)
7/8”
TYP.*
2 1/8”
1 5/8”
1 13/16”
TYP*
1 13/16”
TYP.
1 13/16”
TYP.*
1 13/16”
TYP.*
5/16”
TYP*
5/16”
TYP.*
5/16”
TYP.*
8”
Y
P*
1/2”
TYP*
2 11/16”
3” 1/8
2 7/8”
5”
1 1/4”
5 7/8” 3 1/16”
4 3/4” 5 7/8”
5/16”
TYP.*
1 1/4”
2 3/16” TYP.
(2 PLACES)*
G
F
F1 1/4”
1” TYP.
(2 PLACES)*
4 3/4”
3 1/16”
F
2 3/16” TYP.
(2 PLACES)*
G
AIRFLOW
AIRFLOW AIRFLOW
PRIMARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
PRIMARY DRAIN
PRIMARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
PRIMARY DRAIN
PRIMARY DRAIN
NOTES:
1. CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY.
2. ALL DIMENSIONS ARE IN ”INCHES” UNLESS NOTED.
PRIMARY DRAIN
SECONDARY DRAIN PRIMARY DRA
SECONDARY
D
AIRFLOW
SECONDARY DRAIN
PRIMARY DRAIN
Horizontal Left
FEM4P, FSM4P (as shipped)
Upflow
(as shipped) Downflow
(field converted with accessory kits) Horizontal Right
FEM4P, FSM4P (field converted with accessory kits)
Dimensions English (Inches)SD48954_A
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
4496 51 5502 02
Specifications are subject to change without notice.
273.0
157.2
66.7
47.6
77.8
119.1
25.4
258.8
560.4
34.9
49.2
OPENING
503.2
54.0
25.4 31.8
A
23.8
MODU
L
30.2
E
25.4
127.0
D
241.3
22.2279.4
44.4
482.6
COIL ACCESS
PANEL
DISCONNECT OR
CIRCUIT BREAKER
LOCATION
LIQUID LINE CONNECTION
SUCTION LINE CONNECTION
FITTING
PANEL
B
C
ACCESS PANEL CONFIG. FOR
SLOPE COILS
AND
TOP VIEW
LIQUID LINE
CONNECTION
LIQUID LINE
CONNECTION
SUCTION LINE
CONNECTION
SLOPE COIL DETAILS
CONNECTION LOCATIONS SHOWN
FOR UPFLOW OR HORIZ.
LEFT APPLICATIONS
FOR LOW VOLTAGE
CONTROL WIRING
INLET AIR
INLET AIR
INLET AIR
OUTLET AIR
22.23, 27.78
50.80 DIA. K.O.’S
FOR HIGH VOLTAGE
POWER WIRING
OPENING
H
J
Dimensions MM (SI Metric)SD48954_A
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
496 51 5502 02 5
Specifications are subject to change without notice.
SUCTION:
FEM4P: 18 and 24 — 15.88 I.D. SWEAT
30 and 36 — 19.05 I.D. SWEAT
42 and 48 — 22.23 I.D. SWEAT
FSM4P: 18, 24, 30, 36 — 19.05 I.D. SWEAT
42 and 48 — 22.23 I.D. SWEAT
LIQUID: 9.53 I.D. SWEAT
CONDENSATE: 19.0 FPT
UNIT CONNECTION SIZES
Dimensions MM (SI Metric)SD48954_A
200.0 30.2
38.1
12.7
TYP.*
200.0
30.2
38.1
31.8
82.6
41.3 82.6 65.1
73.0
25.4 TYP.
(2 PLACES)*
11.1 TYP.
(4 PLACES)*
25.4 TYP.
(2 PLACES)
11.1 TYP.
(4 PLACES)
22.2
TYP.*
54.0
41.3
46.0
TYP*
46.0
TYP.
46.0
TYP.*
8.0
TYP*
8.0
TYP.*
8.0
TYP.*
22.2
TYP.*
68.3
79.4
73.0
127.0
31.8
149.2 77.8
120.6 149.2
8.0
TYP.*
12.7
TYP.*
31.8
55.6 TYP.
(2 PLACES)*
G
F
F31.8
25.4 TYP.
(2 PLACES)*
120.6
77.8
F
55.6 TYP.
(2 PLACES)*
G
AIRFLOW
AIRFLOW AIRFLOW
PRIMARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
ACOIL
PRIMARY DRAIN
PRIMARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
PRIMARY DRAIN
PRIMARY DRAIN
PRIMARY DRAIN
SECONDARY DRAIN
AIRFLOW
SECONDARY DRAIN
PRIMARY DRAIN
Horizontal Left
FEM4P, FSM4P (as shipped)
Upflow
(as shipped) Downflow
(field converted with accessory kits) Horizontal Right
FEM4P, FSM4P (field converted with accessory kits)
Horizontal Left
FEM4P, FSM4P (as shipped)
Upflow
(as shipped) Downflow
(field converted with accessory kits) Horizontal Right
FEM4P, FSM4P (field converted with accessory kits)
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
6496 51 5502 02
Specifications are subject to change without notice.
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
496 51 5502 02 7
Specifications are subject to change without notice.
DIMENSIONAL DATA (refer to drawings)
Model Size
(tons)
Dimensions inches (English) Coil
Type
Ship.
WT lbs.
A B C D E F G H J Suct. Liquid
FEM4P1800
11/2
4211/16 145/16 127/16 125/16 107/16 181/8 185/8 12 5/8
3/8 Slope
112
FSM4P1800 475/8 175/8 153/4 155/8 153/8 231/8 235/8 3/4 117
FEM4P2400
2
4211/16 145/16 127/16 125/16 107/16 181/8 185/8 12 5/8
3/8 Slope
112
FSM4P2400 495/8 175/8 153/4 155/8 153/8 231/8 235/8 3/4 128
FEM4P3000
21/2
495/8 175/8 153/4 155/8 153/8 231/8 235/8 17
3/4 3/8 Slope
122
FSM4P3000 537/16 211/8 191/4 191/8 193/16 2615/16 271/2 145
FEM4P3600
3
495/8 175/8 153/4 155/8 153/8 231/8 235/8 17
3/4 3/8 Slope
122
FSM4P3600 537/16 211/8 191/4 191/8 193/16 2615/16 271/2 148
FEM4P4200 31/2 495/8 211/8 191/4 191/8 1511/16 237/16 231/8 — — 7/8 3/8 “A” 157
FSM4P4200 495/8 211/8 191/4 191/8 1511/16 237/16 231/8 156
FEM4P4800 4495/8 211/8 191/4 191/8 1511/16 237/16 231/8 — — 7/8 3/8 “A” 157
FSM4P4800 537/16 2411/16 223/4 2211/16 191/2 271/4 2615/16 182
Model Size
(tons)
Dimensions mm (SI Metric) Coil
Type
Ship.
WT kg
A B C D E F G H J Suct. Liquid
FEM4P1800
11/2
1084 364 316 313 265 460 473 305 16
10 Slope
51
FSM4P1800 1210 448 400 397 391 587 600 19 53
FEM4P2400
2
1084 364 316 313 265 460 473 305 16
10 Slope
51
FSM4P2400 1261 448 400 397 391 587 600 19 58
FEM4P3000
21/2
1261 448 400 397 391 587 600 305
19 10 Slope
55
FSM4P3000 1357 537 489 486 487 684 699 66
FEM4P3600
3
1261 448 400 397 391 587 600 305
19 10 Slope
55
FSM4P3600 1357 537 489 486 487 684 699 67
FEM4P4200 31/2 1261 537 489 486 399 595 587 — — 22 10 “A” 71
FSM4P4200 1261 537 489 486 399 595 587 71
FEM4P4800 41261 537 489 486 399 595 587 — — 22 10 “A” 71
FSM4P4800 1357 627 578 576 495 692 684 83
PHYSICAL DATA
Model Size
1800 2400 3000 3600 4200 4800
Metering Device** Factory Installed Piston Size (R410A)
FEM4P 49 55 61 67 76 80
FSM4P 52 57 67 70 76 80
Blower Data
CFM
(nominal)
FEM4P 600 800 1000 1200 1400 1600
FSM4P 600 800 1000 1200 1400 1600
Motor Type FEM4P ECM 5speed
FSM4P PSC (Permanent Split Capacitor) 2speed
HP FEM4P 1/3 1/3 1/3 1/2 1/2 3/4
FSM4P 1/6 1/4 1/3 1/3 1/2 1/2
Filter Data (washable, available as accessory)
FEM4P 13 x 211/2 163/8 x 211/2 197/8 x 211/2
FSM4P 163/8 x 211/2 197/8 x 211/2 23-5/16 x 21-1/2
Coil Data Face Area ft2 (m2)
FEM4P 2.23 (0.21) 2.23 (0.21) 2.97 (0.28) 2.97 (0.28) 4.45 (0.41) 4.45 (0.41)
FSM4P 2.97 (0.28) 2.97 (0.28) 3.46 (0.32) 3.46 (0.32) 4.45 (0.41) 5.93 (0.55)
Refrigerant Line Connections (sweat)
FEM4P Liquid inch (mm) 3/8 (10)
Suction inch (mm) 5/8 (16) 5/8 (16) 3/4 (19) 3/4 (19) 7/8 (22) 7/8 (22)
FSM4P Liquid inch (mm) 3/8 (10)
Suction inch (mm) 3/4 (19) 3/4 (19) 3/4 (19) 3/4 (19) 7/8 (22) 7/8 (22)
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
8496 51 5502 02
Specifications are subject to change without notice.
ELECTRICAL DATA, FAN COIL ONLY WITHOUT ELECTRIC HEAT
Model
208/230V, single phase, 60 Hz
Motor Full Load
Amps (FLA)
Minimum Circuit
Ampacity (MCA)
Maximum Fuse/Ckt Bkr Amps
(Max OverCurrent Protection MOCP)
FEM4P1800 2.8 3.5 15
FEM4P2400 2.8 3.5 15
FEM4P3000 2.8 3.5 15
FEM4P3600 4.1 5.1 15
FEM4P4200 4.1 5.1 15
FEM4P4800 6.0 7.5 15
FSM4P1800 0.9 1.2 15
FSM4P2400 1.4 1.8 15
FSM4P3000 1.4 1.8 15
FSM4P3600 1.7 2.2 15
FSM4P4200 2.8 3.5 15
FSM4P4800 2.7 3.4 15
NOTE: Always check piston size on indoor unit to see if it matches required piston on outdoor unit nameplate. If it does not match, replace indoor piston with piston
size marked on outdoor unit nameplate.
AIRFLOW PERFORMANCE CFM at a given Speed and Static reading
Model Blower Speed Total Static (inches water column)
0.10 0.20 0.30 0.40 0.50 0.60
FEM4P1800
Tap 5 767 739 702 669 620 565
Tap 4 614 569 534 486 436 398
Tap 3 701 660 616 581 537 499
Tap 2 614 569 534 486 436 398
Tap 1 410 350 304 261 228 203
FEM4P2400
Tap 5 969 936 892 835 763 676
Tap 4 826 795 766 743 706 660
Tap 3 826 795 766 743 706 660
Tap 2 701 660 616 581 537 499
Tap 1 617 592 552 507 472 420
FEM4P3000
Tap 5 1108 1090 1065 1034 1009 974
Tap 4 1026 1000 969 938 899 865
Tap 3 1026 1000 969 938 899 865
Tap 2 909 873 842 799 762 724
Tap 1 825 795 757 722 674 634
FEM4P3600
Tap 5 1301 1276 1245 1218 1176 1121
Tap 4 1227 1191 1169 1143 1105 1074
Tap 3 1227 1191 1169 1143 1105 1074
Tap 2 1087 1062 1030 1001 966 930
Tap 1 1026 1000 969 938 899 865
FEM4P4200
Tap 5 1560 1544 1507 1464 1424 1358
Tap 4 1419 1397 1358 1320 1279 1239
Tap 3 1419 1397 1358 1320 1279 1239
Tap 2 1249 1220 1184 1142 1093 1052
Tap 1 1242 1205 1158 1110 1069 1026
FEM4P4800
Tap 5 1743 1712 1679 1642 1610 1574
Tap 4 1669 1634 1599 1564 1531 1499
Tap 3 1669 1634 1599 1564 1531 1499
Tap 2 1452 1413 1377 1339 1308 1271
Tap 1 1300 1256 1221 1182 1142 1101
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
496 51 5502 02 9
Specifications are subject to change without notice.
AIRFLOW PERFORMANCE CFM at a given Speed and Static reading
Model Blower
Speed
Total Static (inches water column)
0.10 0.20 0.30 0.40 0.50 0.60
208V 230V 208V 230V 208V 230V 208V 230V 208V 230V 208V 230V
FSM4P1800 High 742 825 707 768 642 714 568 648 466 526 403 434
Low 541 608 480 564 417 511 357 431 299 363 n/a 304
FSM4P2400 High 1041 1112 969 1030 888 936 774 791 573 654 341 438
Low 874 1014 838 953 781 868 684 740 506 573 341 418
FSM4P3000 High 1256 1327 1186 1242 1071 1132 952 1005 704 791 459 482
Low 965 1117 949 1074 916 1019 805 902 575 637 396 447
FSM4P3600 High 1306 1490 1264 1418 1207 1338 1135 1241 1043 1127 842 937
Low 1164 1335 1144 1290 1108 1226 1052 1148 970 1048 697 855
FSM4P4200 High 1723 1768 1639 1681 1544 1576 1435 1465 1309 1340 1144 1182
Low 1387 1543 1358 1488 1311 1410 1237 1315 1137 1200 997 1047
FSM4P4800 High 1902 1941 1803 1867 1706 1767 1593 1648 1472 1512 1303 1371
Low 1671 1777 1630 1711 1563 1630 1479 1528 1370 1412 1218 1266
- Airflow outside 450 cfm/ton.
NOTES:
1. Airflow based upon dry coil at 230v with factoryapproved filter and electric heater (2 element heater sizes 1800 through 3600, 3 element
heater sizes 4200 through 4800). For FEM4P models, airflow at 208 volts is approximately the same as 230 volts because the ECM motor
is a constant torque motor. The torque doesn’t drop off at the speeds the motor operates.
2. To avoid potential for condensate blowing out of drain pan prior to making drain trap:
Return static pressure must be less than 0.40 in. wc.
Horizontal applications of 4200 4800 sizes must have supply static greater than 0.20 in. wc.
3. Airflow above 400 cfm/ton on 48004800 size could result in condensate blowing off coil or splashing out of drain pan.
STATIC PRESSURE CORRECTION FROM DRY TO WET COIL (inches of water column)
Model
FEM4P
CFM
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
1800 0.034 0.049 0.063 — — — — — — — — — —
2400 0.049 0.063 0.076 0.089 — — — — — — — — —
3000 — — — 0.049 0.059 0.070 0.080 — — — — — — —
3600 — — — — 0.070 0.080 0.090 0.099 — — — — —
4200 — — — — — — — 0.049 0.056 0.063 0.070 — — —
4800 — — — — — — — — — 0.063 0.070 0.076 0.083 0.090
Models
FSM4P
CFM
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
1800 0.016 0.027 0.038 — — — — — — — — — —
2400 0.016 0.027 0.038 0.049 0.059 — — — — — — — — —
3000 — — — 0.036 0.046 0.055 0.064 — — — — — — —
3600 — — — — 0.055 0.064 0.073 0.081 — — — — —
4200 — — — — — — — 0.049 0.056 0.063 0.07 — — —
4800 — — — — — — — — — 0.038 0.043 0.049 0.054 0.059
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
10 496 51 5502 02
Specifications are subject to change without notice.
MINIMUM CFM WHEN USING ELECTRIC HEAT
Model
FEM4P
HEATER kW
3 5 8 9 10 15 18 20 24 30
1800 525 525 525 600
2400 700 700 700 700 775
3000 875 875 875 875 1060
3600 — 1050 970 970 970 920 1040
4200 1225 1225 1225 1225 1225 1225
4800 1400 1400 1400 1400 1400 1400 1400 1400
Note: Speed Tap 4 (white wire) is used for electric heat only. White wire must remain on tap 4.
Models
FSM4P
HEATER kW
3 5 8 9 10 15 18 20 24 30
1800 525 525 525 600
2400 700 700 700 700 775
3000 875 875 875 875 1060
3600 — 1050 970 970 970 920 1040
4200 1225 1225 1225 1225 1225 1225
4800 1400 1400 1400 1400 1400 1400 1400 1400
Note: Values indicate low or medium speed.
STATIC PRESSURE CORRECTION FOR ELECTRIC HEATERS (inches of water column)
Airflow performance chart was developed using fan coils with 10 kW electric heater (2 elements) in the 1800 3600 model
sizes, and 15 kW electric heaters (3 elements) in the 4200 4800 model sizes.
When using a different number of heater elements, adjust the static pressure numbers by adding or subtracting the values in
this table (for a given CFM, more electric heater elements create higher static pressure drop).
Model
Size
Heater kW
No Heater 3 or 5 8 or 10 9 or 15 20 18, 24, or 30
Number of Heat Elements
0 1 2 3 4 6
1800 +0.02 +0.01 0 0.02 0.04
2400 +0.02 +0.01 0 0.02 0.04
3000 +0.02 +0.01 0 0.02 0.04
3600 +0.02 +0.01 0 0.02 0.04
4200 +0.04 +0.02 0 0.02 0.10
4800 +0.04 +0.02 0 0.02 0.10
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
496 51 5502 02 11
Specifications are subject to change without notice.
ELECTRIC HEATER ELECTRICAL DATA
Heater Model Heater kW
P
H
A
S
E
INTERNAL
CIRCUIT
PROTECTION
HEATER AMPS
208/230V
BRANCH CIRCUIT
Min Ampacity k
208/230V
Min Wire Size (AWG)
208/230V 1
Min Gnd Wire Size
208/230V
Max Fuse/Ckt Bkr Amps
208/230V
Max Wire Length
208/230V (Ft)‡‡
Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit
230v 208v L1,l2 L3,L4 L1,L2 L3,L4 L1, L2 L3, L4 L1, L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,L4
EHK05AKN* 5 3.8 1 None 18.1/20.0 26.0/28.4 10/10 — — 10/10 — — 30/30 — — 66/66 — —
EHK05AKN** 5 3.8 1 None 18.1/20.0 31.2/33.5 8/8 — — 10/10 — — 35/35 — — 85/88 — —
EHK05AKB* 5 3.8 1 Ckt Bkr 18.1/20.0 26.0/28.4 10/10 — — 10/10 — — 30/30 — — 66/66 — —
EHK05AKB** 5 3.8 1 Ckt Bkr 18.1/20.0 31.2/33.5 8/8 — — 10/10 — — 35/35 — — 85/88 — —
EHK07AKN 8 6.0 1 None 28.9/32.0 44.7/48.5 8/8 — — 10/10 — — 45/50 — — 59/60 — —
EHK07AKB 8 6.0 1 Ckt Bkr 28.9/32.0 44.7/48.5 8/8 — — 10/10 — — 45/50 — — 59/60 — —
EHK09AKCN{9 6.8 1 None 32.8/36.0 49.5/53.5 8/6 — — 10/10 — — 50/60 — — 54/87 — —
9 6.8 3 None 18.8/20.8 32.0/34.5 8/8 — — 10/10 — — 35/35 — — 83/85 — —
EHK10AKN 10 7.5 1 None 36.2/40.0 53.8/58.5 6/6 — — 10/10 — — 60/60 — — 78/80 — —
EHK10AKB 10 7.5 1 Ckt Bkr 36.2/40.0 53.8/58.5 6/6 — — 10/10 — — 60/60 — — 78/80 — —
EHK15AKF 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76
EHK15AKB 15 11.3 1 Ckt Bkr 36.2/40.0 18.1/20.0 53.8/58.5 22.7/25.0 6/6 10/10 10/10 10/10 60/60 25/25 78/80 75/76
EHK15AHN 15 11.3 3 None 31.3/34.6 47.7/51.8 8/6 — — 10/10 — — 50/60 — — 56/90 — —
EHK18AHN 18 13.5 3 None 37.6/41.5 55.5/60.4 6/6 — — 10/8 — — 60/70 — — 76/77 — —
EHK20AKF 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59
EHK20AKB 20 15.0 1 Ckt Bkr 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 6/6 8/8 10/10 10/10 60/60 50/50 78/80 59/59
EHK25AHCF}24 18.0 3 Fuse 50.1/55.4 71.2/77.8 4/4 — — 8/8 — — 80/80 — — 94/95 — —
24 18.0 1 Fuse 86.7/95.5 — 116.9/127.9 1/1 — — 6/6 — — 125/150 — — 115/116 — —
EHK30AHCF}30 22.5 3 Fuse 62.6/69.2 86.8/95.0 3/3 — — 8/8 — — 90/100 — — 97/98 — —
30 22.5 1 Fuse 109.0/120.0 — 144.8/158.5 0/00 — — 6/6 — — 150/175 — — 117/150 — —
FIELD MULTIPOINT WIRING OR 24 AND 30 KW SINGLE PHASE
Heater Model
Heater kW
P
H
A
S
E
Heater Amps 208/230V Minimum Circuit Ampacity
208/230V k
Minimum Wire Size (AWG)
208/230V}
Min Gnd
Wire
Size
208/230
V
Max Fuse/Ckt Bkr Amps
208/230V
Max Wire Length 208/230V
(FT)}}
L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6
230V 208V
EHK25AHCF}24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73
EHK30AHCF}30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59
Notes:
1Copper wire must be used. If other than uncoated (non-plated), 75°C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National
Electric Code (ANSI/NFPA 70).
* When used with Fan Coil model sizes 2400, 3600.
** When used with Fan Coil model sizes 4200, 4800.
kIncludes blower motor amps of largest Fan Coil used with heater.
{Supplied as single phase, field convertible to 3-phase.
}Supplied as 3-phase, field convertible to single phase, single or multiple supply circuits.
}} Length shown is as measured one way along wire path between unit and service panel for a voltage drop not to exceed 2%.
PRODUCT SPECIFICATIONS Fan Coils: FEM4P, FSM4P
12 496 51 5502 02
Specifications are subject to change without notice.
ACCESSORIES
Part Number Description
Use with models
FSM4P models FEM4P models
EBAC01DSC Disconnect Kit use with All single phase Heaters 5 kW thru 10 kW
EBAC01NCB
Downflow Base Kit
1800, 2400
EBAC02NCB 2400 3000, 3600
EBAC03NCB 3000, 3600, 4200, 4800 4200, 4800
EBAC01DFS Downflow Conversion Kit Slope Coil 2400, 3000, 3600 1800, 2400, 3000, 3600
EBAC02DFA Downflow Conversion Kit “A” Coil 4200, 4800 4200, 4800
EBAC01SPK Single Point Wiring Kit only for use with 15 kW & 20 kW fused heaters
Square Dr part #
QOU14100JBAF *
Single Point Wiring Kit Square Dr
Jumper Bar Assembly
Only for use with
EHK15AKB and EHK20AKB breaker heaters
EBAC01FKS
Filter Kit (washable, box of 12)
1800, 2400
EBAC01FKM 2400 3000, 3600
EBAC01FKL 3000, 3600, 4200 4200, 4800
EBAC01FKX 4800
NASA00101FR Standard Filter Rack
(12 x 20 x 1 filter required) 1800, 2400
NASA00201FR Standard Filter Rack
(16 x 20 x 1 filter required) 2400 3000, 3600
NASA00301FR Standard Filter Rack
(20 x 20 x 1 filter required) 3000, 3600, 4200 4200, 4800
NASA00401FR Standard Filter Rack [quantity 2]
(12 x 20 x 1 filter required) 4800
EBAC01PLG No Heat (Plug) Kit (box of 6) Factory Installed
EBAC01CTK PVC Condensate Trap Kit (box of 50) ALL ALL
EBAC01GSK Downflow Gasket Kit ALL
ALL
(required for horizontal right
and downflow)
NAEB40501TX
TXV Kit, R410A, Aluminum Coil Only
1800AL, 2400AL, 3000AL 1800AL, 2400AL, 3000AL
NAEB40601TX 3600AL, 4200AL 3600AL, 4200AL
NAEB40701TX 4800AL 4800AL
NAEB20101TX TXV Kit, R22, Aluminum Coil Only
1800AL, 2400AL, 3000AL,
3600AL, 4200AL
1800AL, 2400AL, 3000AL,
3600AL, 4200AL
NAEB20201TX 4800AL 4800AL
* Square D part number given for reference only. Check with local Square D supplier.
ELECTRIC HEATERS
Part Number Description Use with Model Sizes
EHK05AKN 5 kW, single phase, no internal circuit protection ALL
EHK05AKB 5 kW, single phase, with circuit breakers ALL
EHK07AKN 8 kW, single phase, no internal circuit protection ALL
EHK07AKB 8 kW, single phase, with circuit breakers ALL
EHK09AKCN 9 kW, supplied as single phase, field convertible to 3phase,
no internal circuit protection 3600, 4200, 4800
EHK10AKN 10 kW, single phase, no internal circuit protection ALL
EHK10AKB 10 kW, single phase, with circuit breakers ALL
EHK15AKF 15 kW, single phase, with fuses 2400, 3000, 3600, 4200, 4800
EHK15AKB 15 kW, single phase, with circuit breakers 2400, 3000, 3600, 4200, 4800
EHK15AHN 15 kW, 3phase, no internal circuit protection 3600, 4200, 4800
EHK18AHN 18 kW, 3phase, no internal circuit protection 4200, 4800
EHK20AKF 20 kW, single phase, with fuses 3000, 3600, 4200, 4800
EHK20AKB 20 kW, single phase, with circuit breakers 3000, 3600, 4200, 4800
EHK25AHCF 24 kW, supplied as 3phase, field convertible to single phase, with fuses 4800
EHK30AHCF 30 kW, supplied as 3phase, field convertible to single phase, with fuses 4800
Copyright 2015 International Comfort Products
Lewisburg, Tennessee 37091 USA
www.GoAirquest.com
Page 1 of 12 - 49651550202  Airquest FEM4P
Page 2 of 12 - 49651550202  Airquest FEM4P
Page 3 of 12 - 49651550202  Airquest FEM4P
Page 4 of 12 - 49651550202  Airquest FEM4P
Page 5 of 12 - 49651550202  Airquest FEM4P
Page 6 of 12 - 49651550202  Airquest FEM4P
Page 7 of 12 - 49651550202  Airquest FEM4P
Page 8 of 12 - 49651550202  Airquest FEM4P
Page 9 of 12 - 49651550202  Airquest FEM4P
Page 10 of 12 - 49651550202  Airquest FEM4P
Page 11 of 12 - 49651550202  Airquest FEM4P
Page 12 of 12 - 49651550202  Airquest FEM4P

Navigation menu