Ampd102Dante Pdf User Manual

2017-03-29

User Manual: Pdf Ampd102Dante AMPD102DANTE pdf kavson.co.uk

Open the PDF directly: View PDF PDF.
Page Count: 2

The D Series represents the global benchmark for digital audio hearing loop systems. The compact, elegant and sturdy units not
only feature digital signal processing and networking functionality, but are also the most versatile and powerful solution available.
Versions also feature a dedicated input for plug and play network audio.
The D Series range consists of 10 and 14 Amp dual output class 'D' drivers; meaning a 60%+ increase in energy efciency
over existing solutions. Both drivers feature capacitive touch front panels with intuitive menus, built in test signals, and are fully
networkable with a Wi-Fi accessible standard browser based control panel for remote set-up, monitoring and email alerts.
The D10-2 features 10 Amps per loop output plus ample voltage headroom, making it the most exible solution on the
market, suitable for a huge range of applications. The added power of the D14-2 provides a solution for installations in
environments containing very high levels of metal, previously not possible without the use of combiners.
In another rst for high-power Class D Induction Loop drivers, installation can be performed with total condence, as unique multi-
stage ltering ensures compatibility with both other system equipment and global EMC regulations. The D Series also
boasts Dual slope Metal Loss Control that caters for a wide range of metal loss frequency characteristics.
Features
• inputfornetworkaudio
• Drives2outputchannelsat10or14ARMSeach,
featuringaccurateandstable90°phaseshift
• Networkablewithremotebrowserinterface
• Digitaldisplay&intuitive'touch'menusystem
-3modes;Main,Status&Quick
• HighlyenergyefcientClass-Damplierwith
lowheatdissipation
• Upto2x1,300m2PerimeterLoopsarea
coverage
• Upto3,300m2MultiLoopLowLossarea
coverage
• Compact1Urackmountunitwithinternal
transformerforsimplerackinstallation
• Optimisedforspeechfrequencieswith
unmatchedintelligibility&capableofhigh
qualitymusicalreproduction
• AGC&DualSlopeMLC
• Activestatusmonitoring&remotefault
reportingviaemail
• Datacompliantwith:IEC62489-1Standard
Datasheet
D Series Networkable DSP MultiLoop Drivers
Applications include
•LectureTheatres&transportconcourse
•Stadia,SportsHalls,Cinemas&Theatres
MultiLoop™SystemDesignCongurations
MultiLoop Drivers can be used for different types of loop layout. You will
need a MultiLoop system design for the loop layout which you can obtain
from Ampetronic, or have your own design approved by Ampetronic free of
charge.
PerimeterMultiLoops
Two channels drive single area loops either side by side or
overlaid.
Suitable for applications where there is no metal in the
buildings construction, or in areas of moderate metal up to
a maximum loop width of 5 meters.
SimpleMultiLoops
Parallel loop segments with adjacent cables for ease
of installation. Does not give the even coverage of loss
control or low spill loops, with dips in level between loops.
Suitable for xed seating areas, or where dips in eld
strength are acceptable.
LossControlMultiLoops
Multiple loop segments in two patterns each driven by one
output channel.
Best for optimum even area coverage across any
area. Suitable for large areas and buildings with metal
construction.
LowSpillMultiLoops
Similar in design to Low Loss MultiLoop but with a more
complex pattern that requires more cable.
Suitable for applications where loops are close together
or where condentiality is an issue. Low Spill MultiLoops
require careful and precise design.
Issue no UP39003 - 2
Website: www.ampetronic.co Email: sales@ampetronic.co or support@ampetronic.co
Telephone +44 (0)1636 610062 Fax +44 (0)1636 610063
Scenario SystemDesignCoverage(m2)
1:1Perimeter 3:1Perimeter SimpleMultiLoop LossControl LowSpill
No Metal Loss (0dB)* 2 x 1,300 2 x 1,450 1,600 3,300# 1,225
Moderate Metal Loss (-5dB)** Max 5m width Max 5m width 925 925 700
High Metal Loss (-10dB)*** Max 5m width Max 5m width 425 400 340
Severe Metal Loss (-15dB)**** n/a n/a 225 180 120
No Metal Loss (0dB)* 2 x 1,000 2 x 1,450 1,600 3,300 1,225
Moderate Metal Loss (-5dB)** Max 5m width Max 5m width 925 925 700
High Metal Loss (-10dB)*** Max 5m width Max 5m width 425 350 270
Severe Metal Loss (-15dB)**** n/a n/a n/a n/a n/a
D10-2 D14-2
Typical scenarios are based on *a building with no structural metal, **a building with reinforced concrete (re-bar) construction and ***a room with steel raised access oor tiles, ****a room with
steel decking or reinforced concrete and raised access oor tiles. #Special large-area system, no metal loss outdoor areas
TypicalD-SeriesMaxAreaCoverageScenarios
D Series Product Information & Specifications
INPUTS
Power 160/80W 230V AC nominal, 45-65Hz [120V option available]
Power switch on front panel
Input1&2 XLR balanced input with programmable switchable
Programmable between microphone and line via panel menu
Microphone/ Microphone specication; 200 - 600Ω, sensitivity -64dBu.
Line Selectable 12V phantom power on microphone only
Line sensitivity; -39dBu
SlaveIn 6.35mm jack socket for linking more than one amplier.
Inserting plug disables other inputs
RJ45 Ethernet input
OUTPUTS
LoopOutput 33.9Vrms (45Vpk) at maximum output current per channel
DriveVoltage
LoopOutput D10-2
DriveCurrent 10Arms (14.1Apk) up to 60 seconds continuous 1kHz sine
wave, peak >14.1A per channel
Cont. pink noise 4.7Arms short term peaks >14.1A per ch.
D14-2 
14Arms (19.8Apk) up to 60 seconds continuous 1kHz sine
wave, peak >19.8A per channel
Cont. pink noise 6.6Arms short term peaks >20A per ch.
Level controlled via front panel menu or network
Drive current indicated on two 4-LED displays in 6dB
increments
SlaveOut 6.35mm jack socket to connect to other slave ampliers
LoopConnectors
Neutrik NL4 Speakons (supplied) for each output
LoopMonitor Provides access to monitor actual loop current via a
3.5mm stereo headphone connector on front panel
Channel A on left, channel B on right
DCOutput Resettable, fuse protected 12V 0.1A. Operation can be
congured via menu.
AUDIOSYSTEM
Frequency 80Hz to 6.5kHz
Response
Distortion THD+N <0.2% 1kHz sine at full current
Automatic The AGC is optimised for speech. Dynamic range >36dB
GainControl
MetalLoss Corrects system frequency response due to metal
Correction structures in a building. Gain constant at 1kHz, adjustable
gain slope from 0 to 4dB per octave in 0.25dB increments.
Custom 2 slope MLC allows different slopes and
transition frequency to be set via the menu.
This does not compensate for signal loss from metal
structures which can be signicant.
PhaseShift User selectable at 0° or 90° between outputs
ADDITIONALFUNCTIONS
Fault Indicators on the front panel;
Monitoring Clipping – delivering over the rated voltage (per channel)
Error - Check status in menu
Temperature and loop errors reported via the status menu
Cooling Variable speed fan cooled. Front inlet, rear exhaust.
PHYSICAL
Size Full width 1U 19" rack mount.
Width 430mm Depth 290mm Height 44mm
Mounting Freestanding
Options 1U 19" rack mount (brackets included)
Weight D10-2: 5.5kg
D14-2: 6.9kg,
Environment IP20 rated; 20 to 90% relative humidity; 0 to 35ºC
Standardscompliance
This product is designed to form part of a system that can meet all of the requirements of the international loop performance standard IEC60118-4, and the
relevant parts of BS7594. To fully meet requirements of these standards, correct design, installation, commissioning and maintenance are required.
All specication data has been compiled in accordance with IEC62489-1, the international standard for audio frequency induction loop equipment. Specication
data should only be compared with data compliant to this standard.
This product is CE and RCM marked to all relevant safety and EMC standards, and is NRTL (ETL) approved for sale in North America.

Navigation menu