HOUSING
Steel xture body.
BALLASTS
Energy ecient, thermally protected, automatic
resetting, Class P, high power factor, sound rated A,
magnetic or electronic ballasts. CEE NEMA Premium
compliant.
ELECTRICAL
Standard class “P, thermally protected,
autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CEC-
compliant ballast disconnect is standard.
LENS
Highly ecient acrylic lens with a linear refractive
pattern for even illumination and excellent lamp
obscuration.
OCCUPANCY SENSOR
Hubbell Building Automation Internally mounted
Passive Infrared Occupancy sensor. LED indicator
for easy verication of coverage. Lens has a 1500
square-foot, 360° coverage area at a mounting
height of 10 ft, and a 2:1 radius to height ratio
coverage pattern. Sensor includes an adjustable
time delay, and motion/photocell sensitivity.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Units are UL 924 listed
when equipped with optional battery back-up and
meet requirements of the life safety code /NFPA101.
EXAMPLE BIL4-232-EPLWU
FEATURES
Energy saving luminaire with integrated occupancy controls
Bi-level light control oers safety and security
Ideal for stairwells, parking structures, restrooms and areas
where maximum light levels are not needed when area
is unoccupied
A single low wattage 2' lamp delivers constant light output
while the 4' lamps are controlled by an integral
occupancy sensor
White aluminum body allows for greater heat dissipation
Tool-less access to ballast for ease of maintenance
Can be surface mounted, wall mounted, or suspended
Multiple ballast options available for needed energy savings
and light output
Fail safe operation switches light level to 100% if sensor
is damaged
Optional battery backup available for emergency
egress applications
ORDERING INFORMATION
BIL
SIZE
44'
VOLTAGE
U120V-277V
OPTIONS
EL
Emergency Battery Pack, 2' lamp
500 lumens2
EL5
390-750 Lumens, T5 1-Lamp
EL5H
725-1250 Lumens, T5HO 1-Lamp
FO830
T8 Lamps Installed, 82 CRI, 3000K
FO835
T8 Lamps Installed, 82 CRI, 3500K
F5830
T5 or T5HO Lamps Installed, 85
CRI, 3000K
F5835
T5 or T5HO Lamps Installed, 85
CRI, 3500K
F5841
T5 or T5HO Lamps Installed, 85
CRI, 4100K
F5850
T5 or T5HO Lamps Installed, 85
CRI, 5000K
ODS1 Factory Installed Occupancy
Sensor with daylight harvesting
photosensor, 120/277/347V,
one relay1
NYC NYC Compliant
VH (2) V-Hangers
LAMPS IN
CROSS SECTION
2Two
LAMP TYPE
32 4', T8: 32, 30, 28, or
25 Watt and 2', T8:
17 Watt
28 4', T5: 28 Watt and
2', T5: 14 Watt
54 4', T5HO: 54, 51 or
49 Watt and 2', T5:
14 Watt
PRIMARY BALLAST
EP Electronic T5, T5HO, 1.0 BF
or T8 Programmed Start,
0.88 BF
EPLW Electronic T8, Programmed
Start, 0.77 BF
EPHL Electronic T8, Programmed
Start, 1.18 BF
4 2
MODEL
BIL Bi-Level
Luminaire
U
UNOCCUPIED OCCUPIED
(1) 17 WATT T8 LAMP (1) 17 WATT T8 LAMP &
(2) 32 WATT T8 LAMPS
Ballast Type Watts Lumens Watts Lumens
EP (0.88 BF) 15 989 74 4669
EPLW (0.77 BF) 15 989 62 4208
EPHL (1.18 BF) 15 989 90 5170
1 Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories contact your Columbia Lighting representative.
2 Voltage Required
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
BIL4
Bi-Level Luminaire with Controls / 2-Lamp T8, T5, or T5HO
SURFACE / BIL4Page 1/2 Rev. 08/23/17
Catalog No.
Project Name Type
Date
PROJECT INFORMATION
Horiz 0-180
600
1200
600
1200
015 30 45
90
75
60
105
120
180 165 150 135
0.045.0 90.0
ZONAL LUMEN SUMMARY
Zone Lumens %Lamp %Fixt.
0-30 1041 14.6 20.1
0-40 1742 24.4 33.7
0-60 3241 45.3 62.6
0-90 4599 64.3 88.9
0-180 5175 72.4 100.0
PHOTOMETRIC DATA
RC 80 70 50 0
RW 70 50 30 10 70 50 30 10 50 30 10 0
RCR
175 71 67 64 72 69 65 62 64 61 59 50
268 61 56 51 65 59 54 50 55 51 47 41
361 53 47 42 59 51 46 41 48 43 39 34
456 47 40 35 54 45 39 34 42 37 33 28
551 42 35 30 49 40 34 29 38 32 28 24
647 37 31 26 45 36 30 25 34 29 24 21
744 34 27 23 42 33 27 22 31 25 21 18
841 31 24 20 39 30 24 20 28 23 19 16
938 28 22 18 36 27 21 18 26 21 17 15
10 36 26 20 16 34 25 20 16 24 19 15 13
Luminaire BIL4-232-EPHLU
Photometry based on Photopia
software simulation. For relative
photometry contact Columbia
Lighting. Miro 4 Reector Acrylic Lens
Ballast Electronic T8
Ballast Factor 1.00
Lamp F32T8
Lumens per Lamp 2383
Watts 100
Shielding Angle N/A
Spacing Criterion 0º= 1.27
90º = 1.41
Luminous Opening
in Feet
Length: 3.99
Width: 0.50
Height: 0.34
INDOOR CANDELA PLOT
ENERGY DATA
Total Luminaire Eciency 72.4%
Luminaire Ecacy Rating (LER) N/A
IESNA RP-1-1993 Compliance Noncompliant
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
$N/A based on
3000 hrs. and
$.08 per KWH
LUMINAIRE DATA
Test RWS-3-1x4-1L17-2L32-M4 - CA-PHa Test Date 3/19/08
AVG. LUMINANCE
(Candela/Sq. M.)
0.0 22.5 45.0 67.5 90.0
Average Luminance Angle
06950 6950 6950 6950 6950
30 6621 5988 5641 5575 5572
40 6291 5473 5170 5091 5247
45 6103 5055 4867 5060 5241
50 5589 4582 4639 5025 5245
55 5035 4122 4495 4911 5064
60 4053 3604 4167 4470 4504
65 3038 2933 3866 4216 4252
70 1809 2313 3605 3928 4006
75 941 1874 3224 3599 3816
80 522 1642 3058 3460 3622
85 267 1495 2954 3559 3726
DIMENSIONAL DATA
NOTE: All dimensions are in inches; dimensions and specications are subject to change without notice. Please consult factory or check sample for verication.
COEFFICIENTS OF UTILIZATION (%)
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
6"
4"
54"
10"
0.88"
6"
54"
6"
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
BIL4
Bi-Level Luminaire with Controls / 2-Lamp T8, T5, or T5HO
SURFACE / BIL4Page 2/2 Rev. 08/23/17

Navigation menu