Boschlbb1990 LBB 1990/00 Plena Voice Alarm Controller User Manual
2017-03-29
User Manual: Pdf Boschlbb1990 BOSCHLBB1990 pdf kavson.co.uk
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
Communications Systems | LBB 1990/00 Plena Voice Alarm Controller LBB 1990/00 Plena Voice Alarm Controller ▶ Heart of the Plena Voice Alarm System ▶ Six-zone system controller ▶ Built-in 240 W amplifier ▶ 12 business and emergency control inputs ▶ EN 54‑16 and EN 60849 compliant The Plena Voice Alarm Controller is the heart of the voice alarm system. It is the basis of the Plena Voice Alarm System, and has all the essential functionality for compliance with the EN 60849 and 54‑16 standards, including full system supervision, loudspeaker line impedance supervision, a supervised emergency microphone on the front panel and a supervised message manager. The messages can be merged to allow even more flexible use of pre-recorded announcements and evacuation messages. The controller can be used as a stand-alone system with up to six zones, or expanded to up to 60 zones using additional six-zone routers. Up to eight call stations can be connected. Interconnections are made using standard RJ45 connectors and shielded CAT-5 cable. A built-in 240 W amplifier provides the power for the emergency call channel and BGM. Additional Plena Amplifiers can be added to provide two-channel operation. All amplifiers are supervised. The audio output uses standard analog audio 100 V line switching for full compatibility with the Plena family of public address equipment and Bosch EVAC-compliant loudspeakers. The system is configured using DIP switches for basic functionality and a PC for more advanced functions. Functions The controller has two BGM source inputs and a mic/line input with configurable priority, speech filter, phantom power and selectable VOX activation. A total of 16 priority levels can be specified for microphone, call stations and trigger inputs for optimum system flexibility. The powerful 240 W output section has six transformerisolated 100 V constant-voltage outputs for driving 100 V loudspeakers in six separate zones. The 100 V-technique reduces line losses on longer distances and provides easy parallel connection of multiple loudspeakers. All zones may be individually selected from the front panel, and the BGM output level in each zone can be individually set in six steps. The controller supports A/B wiring. Configuration software is provided on the CD included with the unit. The CD also includes many useful programs, such as MP3-ripping software, a sample-rate converter, various audio and visual tools, and free, MP3-coded music. www.boschsecurity.com 2 | LBB 1990/00 Plena Voice Alarm Controller The amplifier output is also available as a separate output on 100 V and 70 V. A separate 100 V call-only output provides addressing for an area where BGM is not required but where priority announcements are. Six configurable volume-override output contacts are available for overriding local volume controls during priority calls. Both four-wire and three-wire schemes are supported. An LED meter monitors the output. Up to 255 messages can be stored in the internal 16 MB flash ROM, without a need for battery backup. Each message can have any length within the total available capacity. Messages and configurations are uploaded from a PC via USB 2 into the memory, after which the unit operates without a PC connection. The standard WAVformat is used for the messages, and sample rates of 8 kHz up to 24 kHz with 16-bit word length (linear PCM) are supported. This gives up to 17 minutes of recording time with CD-quality signal-to-noise ratio. The unit has 12 contact trigger inputs for business and emergency (EMG) calls. Each can be configured for a message consisting of a sequence of up to eight wave files. In this way some wave files may be used in various combinations with other messages, optimizing flexibility and the amount of storage space used . Multiple messages can be merged to form one integrated message. A zone selection, together with this sequence can be configured for each trigger input. Interconnections Front • Microphone socket Back • • • • • • • • • • • • • • • • • • 12 loudspeaker outputs External amplifier input Amplifier output (on 100 V) Backup power input Call output Six volume override outputs Three status outputs 12 trigger inputs 24 VDC output Two call station connectors (redundant) USB 2 connector Two DE-9 connectors (reserved) External amplifier output Line output connectors Two BGM inputs PC call station input (reserved) Two RC station connectors (redundant) Connector to LBB 1992/00 (router) Certifications and Approvals Region Certification Europe CE Declaration of Conformity TUEVSUED Controls and indicators Front • • • • • • • • • • • • • • • LED power meter 13 system fault LEDs Two fault state buttons Two emergency state buttons Six EMG zone status LED pairs Six EMG zone select buttons Six BGM zone select LEDs Six BGM zone select buttons Six BGM zone volume control knobs Two BGM source status LEDs Three knobs for BGM volume, treble, and bass levels All-call button Indicator test button EMG state button Alert message button Back • • • • • • • • • • • Three service settings DIP switches Calibration switch Four system configuration DIP switches Mains voltage selector Power switch Power cord socket Mic/line level switch Three DIP switches for VOX, speech, phantom power Microphone volume control knob Digital message volume control screw Monitoring speaker volume control knob TUV certificate IEC60849 Poland CNBOP Safety acc. to EN 60065 Immunity acc. to EN 55103-2 Emission acc. to EN 55103-1 Emergency acc. to EN 54‑16 / EN 60849 Installation/Configuration Notes LBB 1990/00 rear view LBB 1990/00 Plena Voice Alarm Controller | 3 Parts Included Mains power supply S/N (flat at max volume) Quantity Component 1 LBB 1990/00 Plena Voice Alarm Controller 1 Power cord 1 Set of 19” mounting brackets 1 Plena VAS CD 1 Installation and User Instructions 1 USB cable >70 dB S/N (flat at min volume/muted) >75 dB Headroom >25 dB Trigger Inputs 12 x (6 EMG, 6 business) Connectors MC1,5 / 14-ST-3,5 Activation Programmable Supervision On EMG inputs, programmable Supervision method Series / parallel resistor 100 V input Technical Specifications Electrical Mains power supply Voltage 230/115VAC, ±15%, 50/60 Hz Current inrush 8A Max power consumption 600 VA Battery power supply Voltage 24 VDC, +15% / -15% Current max 14 A Performance Connector MSTB 2,5 /16-ST Power handling capacity 1000 W Tape output 1x Connector Cinch, 2 x mono Nominal level 350 mV Impedance <1 kohm Loudspeaker outputs Connectors MSTB 2,5 /16-ST, floating 100 V output 700 W rated per zone Volume override types 3-wire, 4-wire (24 V), 4-wire failsafe BGM zone output Attenuation 70 / 50 /35 /25 / 18 / 13 V for 0 / -3 / -6 / -9 / -12 / -15 dB 120 / 60 / 30 / 15 / 8 /4 W Output power (rms/maximum) 240 W / 360 W Power reduction on backup power -1 dB Frequency response 60 Hz to 18 kHz (+1/-3 dB at -10 dB ref. rated output) Connector Type MC 1,5/14-ST-3,5 Distortion <1% at rated output power, 1 kHz Rating 250 V, 7A, voltage free Bass control -8/+8 dB at 100 Hz Emergency active relay NO / COM / NC Treble control -8/+8 dB at 10 kHz Call active relay NO / COM / NC Mic/line input 1x Fault relay NO / COM / NC normally energized (failsafe) Connector XLR, 6.3 mm jack General purpose relays NO / COM Sensitivity 1 mV (mic), 1 V (line) Power consumption Impedance >1 kohm (mic); >5 kohm (line) S/N (flat at max volume) >63 dB (mic); >70 dB (line) S/N (flat at min volme/muted) >75 dB CMRR >40 dB (50 Hz – 20 kHz) Headroom >25 dB Speech filter -3 dB at 315 Hz, high-pass, 6 dB/oct Phantom power supply 12 V (mic mode only) 24 VDC operation VOX trigger level -20 dB (100 µV mic / 100 mV line) or via input contact Max power 14.0 A (336 W) -3 dB 12.5 A (300 W) Limiter Automatic -6 dB 9.5 A (228 W) Line input (BGM and PC call station) Pilot tone* 2.5 A (60 W) Connector Cinch, stereo converted to mono, unbalanced Idle 0.9 A (22 W) Sensitivity 200 mV Impedance 22 kohm Output Contacts Mains operation Max power 550 W -3dB 440 W -6dB 340 W Pilot tone* 136 W Idle 60 W * 20 kHz -20dB with maximum loudspeaker load www.boschsecurity.com 4 | LBB 1990/00 Plena Voice Alarm Controller Messages Ordering Information Data format WAV-file, 16-bit PCM, mono Supported sample rates (fs) 24 / 22.05 / 16 / 12 / 11.025 / 8 kHz Frequency response at fs=24kHz 100 Hz to 11 kHz (+1/-3 dB) at fs=22.05kHz 100 Hz to 10 kHz (+1/-3 dB ) at fs=16kHz 100 Hz to 7.3 kHz (+1/-3 dB ) at fs=12kHz 100 Hz to 5.5 kHz (+1/-3 dB) at fs=11.025kHz 100 Hz to 5 kHz (+1/-3 dB) at fs=8kHz 100 Hz to 3.6 kHz (+1/-3 dB) Distortion <0.1% at 1 kHz S/N (flat at max volume) >80 dB Memory capacity 16 MB Flash ROM Recording / playback time 1000 seconds at fs = 8 kHz 333 seconds at fs = 24 kHz Number of messages 255 max Supervision Flash ROM Continuous checksum control Supervision DAC 1 Hz pilot tone Data retention time >10 years Mechanical Dimensions (H x W x D) 144 x 430 x 370 mm (19" wide, 3U high) Weight Approx. 21.17 kg Mounting 19”rack Color Charcoal Environmental Operating temperature -10 ºC to +55 ºC (14 ºF to +131 ºF) Storage temperature -40 ºC to +70 ºC (-40 ºF to +158 ºF) Relative humidity <95% Acoustic noise level of fan <48 dB SPL at 1 m (max output) Americas: Bosch Communications Systems 12000 Portland Avenue South Burnsville, Minnesota 55337, USA Phone: +1-800-392-3497 Fax: +1-800-955-6831 audiosupport@us.bosch.com www.boschsecurity.com Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems Inc. 011 | Data subject to change without notice T1287851531 | Cur: en-US, V21, 27 Jan 2011 LBB 1990/00 Plena Voice Alarm Controller fully supervised main control unit for Voice Alarm applications. Built-in 240 W amplifier. LBB1990/00 Accessories PLN‑VASLB‑NL Plena VAS labels, Dutch (10 pcs) Dutch, set of 10 pieces, and can be placed on the front panel PLN-VASLB-NL PLN‑VASLB‑DE Plena VAS labels, German (10 pcs) German, set of 10 pieces, and can be placed on the front panel PLN-VASLB-DE PLN‑VASLB‑FR Plena VAS labels, French (10 pcs) French, set of 10 pieces, and can be placed on the front panel PLN-VASLB-FR PLN‑VASLB‑ES Plena VAS labels, Spanish (10 pcs) Spanish, set of 10 pieces, and can be placed on the front panel PLN-VASLB-ES PLN‑VASLB‑IT Plena VAS labels, Italian (10 pcs) Italian, set of 10 pieces, and can be placed on the front panel PLN-VASLB-IT PLN‑VASLB‑FI Plena VAS labels, Finnish (10 pcs) Finnish, set of 10 pieces, and can be placed on the front panel PLN-VASLB-FI PLN‑VASLB‑CZ Plena VAS labels, Czech (10 pcs) Czech, set of 10 pieces, and can be placed on the front panel PLN-VASLB-CZ PLN‑VASLB‑RU Plena VAS labels, Russian (10 pcs) Russian, set of 10 pieces, and can be placed on the front panel PLN-VASLB-RU PLN‑VASLB‑SE Plena VAS labels, Swedish (10 pcs) Swedish, set of 10 pieces, and can be placed on the front panel PLN-VASLB-SE PLN‑VASLB‑DK Plena VAS labels, Danish (10 pcs) Danish, set of 10 pieces, and can be placed on the front panel PLN-VASLB-DK PLN‑VASLB‑PL Plena VAS labels, Polish (10 pcs) Polish, set of 10 pieces, and can be placed on the front panel PLN-VASLB-PL Asia-Pacific: Robert Bosch (SEA) Pte Ltd 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2600 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com Represented by
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : Bosch Security Systems Create Date : 2011:01:27 15:39:03+01:00 Modify Date : 2011:01:27 15:39:03+01:00 Creator : AH Formatter V5.0 MR2a (5,0,2009,0623) for Windows Producer : Antenna House PDF Output Library 2.6.0 (Windows) Title : LBB 1990/00 Plena Voice Alarm Controller Trapped : False Page Count : 4 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools