STR14078144E CE Report
Ce Report CE__Report CE__Report CertsReports 207416 ProductFiles assets.mhint
2016-04-08
: Pdf Ce Report CE__Report CertsReports 207423 ProductFiles
Open the PDF directly: View PDF
.
Page Count: 24
| Download | |
| Open PDF In Browser | View PDF |
CE LINK LIMITED Model: HSW0301D EMC Measurement and Test Report For CE LINK LIMITED Building G, LiCheng Technology Industrial Zone, GongHe Village, ShaJing Town, ShenZhen City, China Test Standards: EN 55022:2010 EN 55024:2010 Product Description: HDMI Switch With Cable Tested Model: HSW0301D Report No.: STR14078144E Tested Date: 2014-07-17 to 2014-07-18 Issued Date: 2014-07-18 Tested By: Mark Chen / Engineer Reviewed By: Lahm Peng / EMC Manager Approved & Authorized By: Jandy so / PSQ Manager Prepared By: Shenzhen SEM.Test Technology Co., Ltd. 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao'an District, Shenzhen, P.R.C.(518101) Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior permitted by Shenzhen SEM.Test Technology Co., Ltd. REPORT NO.: STR14078144E PAGE 1 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D TABLE OF CONTENTS 1.GENERAL INFORMATION....................................................................................................................................3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...............................................................................3 1.2 TEST STANDARDS...................................................................................................................................................4 1.3 TEST METHODOLOGY .............................................................................................................................................4 1.4 TEST FACILITY .......................................................................................................................................................4 1.5 EUT SETUP AND OPERATION MODE ......................................................................................................................5 1.6 PERFORMANCE CRITERIA FOR EMS .......................................................................................................................5 2. SUMMARY OF TEST RESULTS ...........................................................................................................................6 3. RADIATED DISTURBANCE ..................................................................................................................................7 3.1 MEASUREMENT UNCERTAINTY ..............................................................................................................................7 3.2 TEST EQUIPMENT LIST AND DETAILS .....................................................................................................................7 3.3 TEST PROCEDURE ...................................................................................................................................................7 3.4 CORRECTED AMPLITUDE & MARGIN CALCULATION ..............................................................................................8 3.5 ENVIRONMENTAL CONDITIONS ..............................................................................................................................8 3.6 SUMMARY OF TEST RESULTS/PLOTS ......................................................................................................................8 4. ELECTROSTATIC DISCHARGES (ESD) ..........................................................................................................11 4.1 TEST EQUIPMENT LIST AND DETAILS ....................................................................................................................11 4.2 TEST PROCEDURE .................................................................................................................................................11 4.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST DATA ............................................................................................11 5. CONTINUOUS RADIATED DISTURBANCES (R/S) ........................................................................................13 5.1 TEST EQUIPMENT LIST AND DETAILS ....................................................................................................................13 5.2 TEST PROCEDURE .................................................................................................................................................13 5.3 CONTINUOUS RADIATED DISTURBANCES TEST DATA...........................................................................................13 EXHIBIT 1- PRODUCT LABELING .......................................................................................................................14 PROPOSED CE LABEL FORMAT ..................................................................................................................................14 PROPOSED LABEL LOCATION ON EUT .......................................................................................................................14 EXHIBIT 2 - EUT PHOTOGRAPHS........................................................................................................................15 EXHIBIT 3 - TEST SETUP PHOTOGRAPHS ........................................................................................................23 REPORT NO.: STR14078144E PAGE 2 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 1.GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) Client Information Applicant: Address of applicant: Manufacturer: Address of manufacturer: General Description of EUT Product Name: Trade Name: Model No.: Adding Model(s): CE LINK LIMITED Building G, LiCheng Technology Industrial Zone, GongHe Village, ShaJing Town, ShenZhen City, China CE LINK LIMITED Building G, LiCheng Technology Industrial Zone, GongHe Village, ShaJing Town, ShenZhen City, China HDMI Switch With Cable CE-LINK HSW0301D HSW0501D, HSW0201D Note: The test data is gathered from a production sample, provided by the manufacturer. The Color of others models listed in the report is different from main-test model HSW0301D, but the circuit and the electronic construction do not change, declared by the manufacturer. Technical Characteristics of EUT Rated Voltage: Rated Current: Rated Power: Power Adaptor Model: Highest Internal Frequency: Classification of ITE: REPORT NO.: STR14078144E DC 5V 2200mA (0.05A) / / Below 108MHz Class B PAGE 3 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 1.2 Test Standards The following report is prepared on behalf of the CE LINK LIMITED in accordance with EN55022, Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement, and EN61000-3-2, Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase), and EN61000-3-3, Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection, and EN55024, Immunity characteristics Limits and methods of measurement. The objective of the manufacturer is to demonstrate compliance with the standards EN55022, EN61000-3-2, EN61000-3-3, and EN55024 for Information Technology Equipment. Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product maybe which result in lowering the emission/immunity should be checked to ensure compliance has been maintained. 1.3 Test Methodology All measurements contained in this report were conducted with the standards EN55022, EN61000-3-2, EN61000-3-3, and EN55024 for Information Technology Equipment, and all related testing and measurement techniques intentional standards. 1.4 Test Facility FCC – Registration No.: 934118 Shenzhen SEM.Test Technology Co., Ltd. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files and the Registration is 934118. Industry Canada (IC) Registration No.: 11464A The 3m Semi-anechoic chamber of Shenzhen SEM.Test Technology Co., Ltd. has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 11464A. CNAS Registration No.: L4062 Shenzhen SEM.Test Technology Co., Ltd. is a testing organization accredited by China National Accreditation Service for Conformity Assessment (CNAS) according to ISO/IEC 17025. The accreditation certificate number is L4062. All measurement facilities used to collect the measurement data are located at 1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road, Bao’an District, Shenzhen, P.R.C (518101). REPORT NO.: STR14078144E PAGE 4 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 1.5 EUT Setup and Operation Mode The equipment under test (EUT) was configured to measure its highest possible emission/immunity level. The test modes were adapted according to the operation manual for use, more detailed description as follows: Test Mode List: Test Mode Description Remark TM1 Working / EUT Cable List and Details Cable Description Length (M) Shielded/Unshielded With Core/Without Core / / / / Description Manufacturer Model Serial Number PHILIPS DVD Player DVP5986K / BenQ LCD Display FP94VW / Cable Description Length (M) Shielded/Unshielded With Core/Without Core HDMI Cable 0.9 Unshielded Without Core Auxiliary Equipment List and Details Special Cable List and Details 1.6 Performance Criteria for EMS All the test data has been collected, reduced, and analyzed within this report in accordance with Immunity requires the following as specific performance criteria: A. The apparatus shall continue to operate as intended during and after the test. The manufacturer specifies some minimum performance level. The performance level may be specified by the manufacturer as a permissible loss of performance. B. The apparatus shall continue to operate as intended after the test. This indicates that the EUT does not need to function at normal performance levels during the test, but must recover. Again some minimal performance is defined by the manufacture. No change in operating state or loss or data is permitted. C. Temporary loss of function is allowed. Operation of the EUT may stop as long as it is either automatically reset or can be manually restored by operation of the controls. REPORT NO.: STR14078144E PAGE 5 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 2. SUMMARY OF TEST RESULTS Standards Description of Test Item Result Conducted Disturbance N/A Radiated Disturbance Compliant EN61000-3-2 Harmonic Current Emission N/A EN61000-3-3 Voltage Fluctuation and Flicker N/A Electrostatic Discharge Immunity in accordance with IEC 61000-4-2 Compliant Continuous Radiated Disturbances Immunity in accordance with IEC 61000-4-3 Compliant EN55022 Electrical Fast Transient/Burst Immunity in accordance with IEC 61000-4-4 N/A Surges Immunity in accordance with IEC 61000-4-5 N/A Continuous Conducted Disturbances Immunity in accordance with IEC 61000-4-6 N/A EN55024 Power-frequency Magnetic Fields Immunity in accordance with IEC 61000-4-8 N/A Voltage Dips/Interruptions Immunity in accordance with IEC 61000-4-11 N/A N/A: not applicable REPORT NO.: STR14078144E PAGE 6 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 3. Radiated Disturbance 3.1 Measurement Uncertainty Base on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of any radiation emissions measurement is + 5.10 dB. 3.2 Test Equipment List and Details Description Spectrum Analyzer EMI Test Receiver Pre-amplifier Pre-amplifier Trilog Broadband Antenna Horn Antenna Manufacturer R&S R&S Agilent Compliance Direction Model Serial Number Cal. Date Due. Date FSP ESVB 8447F PAP-0118 836079/035 2014-05-28 2015-05-27 825471/005 3113A06717 24002 2014-05-28 2015-05-27 2014-05-28 2015-05-27 2014-05-28 2015-05-27 SCHWARZBECK VULB9163 9163-333 2014-05-24 2015-05-23 ETS 3117 00086197 2014-05-24 2015-05-23 3.3 Test Procedure Test is conducting under the description of EN55022 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement. Antenna Tower 1m-4m 3m EUT SYS 0.8m Turntable Table To EMI Receiver Ground Plane REPORT NO.: STR14078144E PAGE 7 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 3.4 Corrected Amplitude & Margin Calculation The Corrected Amplitude is calculated by adding the Antenna Factor and the Cable Factor, and subtracting the Amplifier Gain from the Amplitude reading. The basic equation is as follows: Corr. Ampl. = Indicated Reading + Antenna Factor + Cable Factor - Amplifier Gain The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of -6dBμV means the emission is 6dBμV below the maximum limit for Class B device. The equation for margin calculation is as follows: Margin = Corr. Ampl. – EN55022 Class B Limit 3.5 Environmental Conditions Temperature: 23° C Relative Humidity: 53% ATM Pressure: 1011 mbar 3.6 Summary of Test Results/Plots According to the data in section 4.6, the EUT complied with the EN55022 Class B standards, and had the worst margin is: -4.05 dB at 32.4109 MHz in the Vertical polarization, 30 MHz to 1 GHz, 3Meters REPORT NO.: STR14078144E PAGE 8 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D Plot of Radiated Emissions Test Data EUT: HDMI Switch With Cable Tested Model: HSW0301D Operating Condition: TM1 Comment: DC 5V Test Specification: No. Horizontal Frequency Reading Correct Result Limit Margin Degree Height (MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) ( °) (cm) 1 99.7676 22.17 7.79 29.96 40.00 -10.04 360 100 peak 2 166.6385 25.91 3.95 29.86 40.00 -10.14 0 100 peak 3 225.4267 26.05 6.63 32.68 40.00 -7.32 26 100 peak 4 793.0281 22.28 13.49 35.77 47.00 -11.23 246 100 peak REPORT NO.: STR14078144E PAGE 9 OF 24 Remark EMC REPORT CE LINK LIMITED Test Specification: No. Model: HSW0301D Vertical Frequency Reading Correct Result Limit Margin Degree Height (MHz) (dBuV/m) Factor(dB) (dBuV/m) (dBuV/m) (dB) ( °) (cm) 1 32.4109 29.33 6.62 35.95 40.00 -4.05 46 150 QP 2 39.7371 27.22 7.86 35.08 40.00 -4.92 89 120 QP 3 92.9974 26.78 7.09 33.87 40.00 -6.13 76 100 peak 4 261.2730 30.08 7.95 38.03 47.00 -8.97 316 100 peak 5 433.3397 27.51 10.54 38.05 47.00 -8.95 267 100 peak REPORT NO.: STR14078144E PAGE 10 OF 24 Remark EMC REPORT CE LINK LIMITED Model: HSW0301D 4. Electrostatic Discharges (ESD) 4.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date ESD Generator TESQ AG NSG 437 161 2014-05-28 2015-05-27 4.2 Test Procedure Test is conducting under the description of IEC61000-4-2. Test Performance Performance Criterion: B Environmental Conditions 26 °C Temperature: Relative Humidity: 55% ATM Pressure: 1011 mbar 4.3 Electrostatic Discharge Immunity Test Data Table 1: Electrostatic Discharge Immunity (Air Discharge) EN 61000-4-2 Test Points -2 +2 -4 +4 -6 +6 -8 +8 N/A / / / / / / / / -8 +8 Test Levels (kV) -15 +15 -15 +15 Table 2: Electrostatic Discharge Immunity (Direct Contact) EN 61000-4-2 Test Points -2 +2 -4 +4 Metal Part B B B B Test Levels (kV) REPORT NO.: STR14078144E -6 PAGE 11 OF 24 +6 EMC REPORT CE LINK LIMITED Model: HSW0301D Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP) EN 61000-4-2 Test Points -2 +2 -4 +4 Front Side A A A A Top Side A A A A Back Side A A A A Left Side A A A A Right Side A A A A Test Levels (kV) -6 +6 -8 +8 -15 +15 +6 -8 +8 -15 +15 Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP) EN 61000-4-2 Test Points Test Levels (kV) -2 +2 -4 +4 Front Side A A A A Top Side A A A A Back Side A A A A Left Side A A A A Right Side A A A A -6 Test Result: Pass REPORT NO.: STR14078144E PAGE 12 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D 5. Continuous Radiated Disturbances (R/S) 5.1 Test Equipment List and Details Description Manufacturer Model Serial Number Cal. Date Due. Date Signal Generator Rohde & Schwarz SMT03 100059 2014-05-28 2015-05-27 Voltage Probe Rohde & Schwarz URV5-Z2 100013 2014-05-28 2015-05-27 Power Amplifier AR 150W1000 300999 2014-05-28 2015-05-27 Power Amplifier AR 25S1G4AM1 305993 2014-05-28 2015-05-27 Trilog Antenna Anechoic chamber SCHWARZBECK VULB9163 9163-333 2014-05-24 2015-05-23 Albatross Projects MCDC ---- 2013-12-26 2015-12-15 5.2 Test Procedure Test is conducting under the description of IEC61000-4-3. Test Performance Performance Criterion: A Environmental Conditions Temperature: 25 °C Relative Humidity: 52% ATM Pressure: 1010 mbar 5.3 Continuous Radiated Disturbances Test Data Frequency step: 1% of fundamental Dwell time: 1 second Modulation: AM by 1kHz sine wave with 80% modulation depth Front Rear Left Side Right Side Frequency Range(MHz) Field (V/m) VERT HORI VERT HORI VERT HORI VERT HORI 80-1000 3 A A A A A A A A Test Result: Pass REPORT NO.: STR14078144E PAGE 13 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D EXHIBIT 1- PRODUCT LABELING Proposed CE Label Format Specifications: Text is Black in color and is justified. Labels are printed in indelible ink on permanent adhesive backing or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT. The ‘CE’ marking must be affixed to the EUT or to its data plate. Where this is not possible or not warranted on account of the nature of the apparatus, it must be affixed to the packaging, if any, and to the accompanying documents. The ‘CE’ marking must have a height of at least 5 mm. If the ‘CE’ marking is reduced or enlarged the proportions given in the above graduated drawing must be respected. Proposed Label Location on EUT CE Label Location REPORT NO.: STR14078144E PAGE 14 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D EXHIBIT 2 - EUT PHOTOGRAPHS EUT View 1 EUT View 2 REPORT NO.: STR14078144E PAGE 15 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D EUT Housing and Board View 1 Solder Board-Component View 1 REPORT NO.: STR14078144E PAGE 16 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D Solder Board-Component View 2 Adding Model: HSW0201D EUT View 1 REPORT NO.: STR14078144E PAGE 17 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D EUT View 2 EUT Housing and Board View 1 REPORT NO.: STR14078144E PAGE 18 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D Solder Board-Component View 1 Solder Board-Component View 2 REPORT NO.: STR14078144E PAGE 19 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D Adding Model: HSW0501D EUT View 1 EUT View 2 REPORT NO.: STR14078144E PAGE 20 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D EUT Housing and Board View 1 Solder Board-Component View 1 REPORT NO.: STR14078144E PAGE 21 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D Solder Board-Component View 2 REPORT NO.: STR14078144E PAGE 22 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D EXHIBIT 3 - TEST SETUP PHOTOGRAPHS Radiation Emission Test View IEC61000-4-2 Test View REPORT NO.: STR14078144E PAGE 23 OF 24 EMC REPORT CE LINK LIMITED Model: HSW0301D IEC61000-4-3 Test View ***** END OF REPORT ***** REPORT NO.: STR14078144E PAGE 24 OF 24 EMC REPORT
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2014:07:18 17:29:37+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2014:07:18 17:30:50+08:00 Metadata Date : 2014:07:18 17:30:50+08:00 Format : application/pdf Creator : Administrator Title : Microsoft Word - STR14078144E.doc Document ID : uuid:076ad764-1732-4d71-a92c-41e81862d47e Instance ID : uuid:ca0445ec-2277-4da5-8255-28b0bd49451f Page Count : 24 Author : AdministratorEXIF Metadata provided by EXIF.tools