No.: CANEC1520080904 Date: 04 Dec 2015 Page 1 of 6
GEM TERMINAL IND.CO.,LTD.
NO.138 LANE513,TA-TUNG ROAD,LU-CHU HSIANG,KAOHSIUNG HSIEN,TAIWAN.
The following sample(s) was/were submitted and identified on behalf of the clients as : PLUG FITTING C5191
PHOSPHOR
SGS Job No. : CP15-065535 - SZ
Tested Sample Info. : PLUG FITTING C5191 PHOSPHOR
Date of Sample Received : 20 Nov 2015
Testing Period : 20 Nov 2015 - 02 Dec 2015
Test Requested : Selected test(s) as requested by client.
Test Method : Please refer to next page(s).
Test Results : Please refer to next page(s).
Conclusion : Based on the performed tests on submitted sample(s), the results of Lead, Mercury,
Cadmium, Hexavalent chromium comply with the limits as set by RoHS Directive
(EU) 2015/863 amending Annex II to Directive 2011/65/EU.
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
Alkene Liang
Approved Signatory
Test Report
Test ReportTest Report
Test Report
No.: CANEC1520080904 Date: 04 Dec 2015 Page 2 of 6
Test Results:
Test Part Description:
Specimen No. SGS Sample ID Description
SN1 CAN15-200809.004 Copper-colored metal
Remarks:
(1) 1mg/kg=1ppm=0.0001%
(2) MDL = Method Detection Limit
(3) ND = Not Detected (<MDL)
(4) “-” = Not Regulated
RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU
Test Method:
(1) With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2) With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3) With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4) With reference to IEC 62321:2008, determination of Hexavalent Chromium by spot test /
Colorimetric Method using UV-Vis.
Test Item(s): Limit
Unit MDL
004
Cadmium(Cd) 100 mg/kg 2 ND
Lead (Pb) 1000
mg/kg 2 13
Mercury (Hg) 1000
mg/kg 2 ND
Hexavalent Chromium (Cr(VI)) - - Negative
Notes:
(1)The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
(2)Spot-test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result is
Negative or cannot be confirmed.)
Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal
or greater than 0.02 mg/kg with 50 cm2 sample surface area.
Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI)
results represent status of the sample at the time of testing.
Test Report
Test ReportTest Report
Test Report
No.: CANEC1520080904 Date: 04 Dec 2015 Page 3 of 6
Material No.: PLUG FITTING C5191
88051DPL-0 92523PS-1 96748PS-2 98042APS-2 98713APS-0
88051DPL-2 92523PS-2 96900PS-2 98042BPL-1 98713PS-0
88051DPS-2 92524PS-0 96900SPS-2 98042EPL-1 98714APS-0
92024LPS-2 92525BS-2 97641BPL-0 98042FPL-1 98714APS-2
92024PS-2 92525PL-0 97711PS-0 98051A 98714BPS-0
92027LPS-2 92525PL-2 97711PS-2 98051B 98714CPS-0
92027PS-2 92526PS-0 97712APS-2 98051M 98714PS-0
92028LPS-2 92526PS-1 97712PS-2 98079DPL-1 98714PS-1
92028PS-2 92526PS-2 97713PS-2 98127PS-0 98714PS-2
92047PS-0 92528PS-0 97714APS-0 98136PL-0 98714APS-0T
92047PS-2 92529PS-0 97714PS-0 98160APS-0 98715APS-0
92053LPS-2 93733PS-2 97714PS-1 98167PS-0 98715PS-0
92053PS-2 95612PL-1 97715APS-0 98170PS-0 98715PS-1
92053SPS-2 95712PL-0 97715PS-0 98170PS-0A 98715PS-2
92059PS-2 95712PL-1 97716APS-0 98172PS-0 98715PS-A0
92083LPS-2 95712PL-1 97716PS-0 98223PS-0 98716PS-0
92083PS-2 96700PS-0 97717PS-0 98223PS-1 98717PS-0
92084PS-2 96700PS-2 97717PS-2 98230PS-0 98718PL-1
92085PS-2 96730PS-0 97718PS-1 98234APS-0 98718PS-1
92517PS-0 96730PS-2 97719PS-1 98236PS-0 98719PL-1
92517PS-1 96735SPS-2 97740LPS-0 98238PS-0 98719PS-1
92518PL-0 96740PS-2 97740PS-0 98239PS-0 98721PS-0
92518PL-1 96741LPS-2 97741APS-0 98283PS-0 98722PS-0
92519PS-0 96741PS-2 97741APS-2 98575PS-0 98728PS-0
92519PS-1 96741SPS-2 97741PS-0 98575PS-1 98728PS-2
92519PS-2 96747APS-0 97742APS-0 98702APS-0 98732APS-0
92520PL-0 96747APS-1 97742PS-0 98702APS-1 98732APS-2
92520PL-1 96747LAPS-0 97747PS-0 98702APS-2 98732CPS-0
Test Report
Test ReportTest Report
Test Report
No.: CANEC1520080904 Date: 04 Dec 2015 Page 4 of 6
92520PL-2 96747LAPS-1 97766PL-0 98702BPS-0 99222PS-0
92521PL-1 96747LPS-1 98042APL-1 98702PS-0 99222PS-2
92522PL-1 96747PS-1 98042APS-0 98702PS-1 99223PS-0
92523PS-0 96747PS-2 98042APS-1 98702PS-2 99761PS-0
98735PL-1 99223PS-2 99831PS-2 M98051A-1W 99775APS-0
98739APS-0 99411PS-0 99846PS-2 M98745P-0W1 99775APS-2
98739LPS-0 99411PS-2 99851PS-0 M98793 99783PS-0
98739PS-0 99465PS-0 99851PS-2 M98793C 99783PS-2
98740DPS-0 99570PS-0 99852PS-0 M98795AP-X 99787PS-2
98740LPS-0 99570PS-2 99852PS-2 M98795A-X 99789PS-0
98740PS-0 99577PS-0 99854PS-0 M98796AP-X 99789PS-1
98741APS-0 99577PS-2 99854PS-2 M98796A-X 99789PS-2
98741BPS-0 99731PS-0 99855PS-0 97733PS-1 99797PS-1
98741PS-0 99737APS-0 99855PS-2 96142PS-2 99831PS-0
98741SPS-0 99737APS-2 99866PS-0 98230APS-0 A98795B
98742PS-0 99737LPS-0 99866PS-2 98238APS-0 A98795BP
98745CPS-0 99737LPS-2 99877PS-0 98741BSPS-0 A98796A
98745PS-0 99737PS-0 99877PS-2 97720PS-0 A98796AP
98746APS-0 99737PS-2 99878PS-0 98752LPS-0 A98796B
98746BPS-0 99741BPS-0 99880PS-2 97722PL-0 A98796BP
98746PS-0 99741PS-0 A61625AP 97723PL-0 M88051PL-1B
98750DPS-0 99741PS-1 A88051EP 98170PS-1 M88052PL-1B
98750PS-0 99741PS-2 A92069-1 88051DPS-1 M88052PL-1BMT
98752PS-0 99745PS-0 A98793A M87642BL-0W M98051A
98752PS-0 99745PS-1 A98793B M87642BL-1W M98051A-1
98760PS-0 99745PS-2 A98793C 98739BPS-0 98732PS-0
98760PS-ODM1
99754PS-2 A98793D 97793PL-0 98732PS-2
98775PL-1 99754PS-2 A98795A M98740P-0W 98733PS-0
98782PL-06 99754SPS-2 A98795AP 98714DPS-0 98733PS-1
98783PL-06 98793BPS-0 98793DPS-0 99165PS-0
98793APS-0 98793CPS-0 99138PS-0 99165PS-2
Test Report
Test ReportTest Report
Test Report
No.: CANEC1520080904 Date: 04 Dec 2015 Page 5 of 6
ATTACHMENTS
ATTACHMENTSATTACHMENTS
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: Bruce Xiao
2) Name of the person in charge of testing: Bella Wang
3) These samples were dissolved totally by pre-conditioning method according to below flow chart
(Cr6+ test method excluded).
Sample Preparation
Sample Measurement
Acid digestion with
microwave/ hotplate
Filtration
Residue
1) Alkali
F
usion /
Dry Ashing
2) Acid to
dissolve
ICP
-
OES/AAS
DATA
Nonm
etallic
material
M
etallic
material
Adding d
igestion
reagent
Heating to
90~95℃ for
extraction
F
iltration and
pH adjustment
Adding
1,5
-
diphenylcarbazide
for color
development
UV
-
Vis
DATA
Spot test
Boiling water
extraction
Add
ing
1,5
-
diphenylcarbazide
for color
development
A red color
indicates the
presence of Cr6+
6+6+
6+. If
necessary, confirm
with UV-Vis.
DATA
Positive
Negative
Pb/Cd
/Hg
Cr
CrCr
Cr
6+
6+6+
6+
Test Report
Test ReportTest Report
Test Report
No.: CANEC1520080904 Date: 04 Dec 2015 Page 6 of 6
Sample photo:
SGS authenticate the photo on original report only
*** End of Report ***
CAN15-200809.004
CAN
CANCAN
CANEC152008090
EC152008090EC152008090
EC1520080904
44
4

Navigation menu