EL USB 1PRO Manual
User Manual: Pdf
Open the PDF directly: View PDF
.
Page Count: 3
| Download | |
| Open PDF In Browser | View PDF |
EL-USB-1-PRO ORDERING INFORMATION Temperature Data Logger with Extended Range Standard Data Logger EL-USB-1-PRO (Data Logger, Software on CD, Battery) Replacement Battery BAT 3V6 2/3AA H TEMP FEATURES • -40 to +125°C (-40 to +257°F) measurement range • Stainless Steel (316 grade) case • Environmental protection to IP67 • USB interface for set-up and data download • Immediate and delayed start logging • Supplied with replaceable high capacity lithium battery and Windows control software. This standalone data logger measures and stores up to 32,510 temperature readings over a -40 to +125ºC (-40 to +257ºF) measurement range. The stainless steel 316 assembly provides protection from corrosion, impact and water ingress to IP67/NEMA 4X. The unit is powered by a 2/3AA 3.6V lithium battery which allows logging for up to 3 years. Setup and downloading is completed by plugging the data logger into a PC’s USB port and running the purpose designed software under Windows 2000, XP, Vista or 7. Downloaded data can then be graphed, printed and exported to other applications. Specifications Minimum Measurement range -40 (-40) Typical Accuracy (overall error) ±0.2 (±0.4) † Internal resolution 0.1 Maximum Unit +125 (+257) °C (°F) ±1.6 (±2.9) °C (°F) °C (°F) Logging rate every 1 s every 12 hr Operating temperature range -40 (-40) +125 (+257) °C (°F) 2/3AA 3.6V High Temperature Lithium Battery Life 1* 3 Year 2** - Between 0°C and 40°C - see graph on page 2 * 10 second logging rate @ -20°C ** 10 second logging rate @ +80°C † EL-WIN-USB (CONTROL SOFTWARE) Lascar’s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows 2000, XP, Vista & 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: • Logger name • °C, °F • Logging rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr) • Data rollover (Allows unlimited logging periods by overwriting the oldest data when the memory is full) • Start date and start time The latest version of the control software may be downloaded free of charge from www.lascarelectronics.com www.lascarelectronics.com Specifications liable to change without prior warning Issue 7 07/2012 S.L. Applies to EL-USB-1-PRO Page 1 of 3 EL-USB-1-PRO Temperature Data Logger with Extended Range DIMENSIONS 17.5 (0.69) All dimensions in mm (inches) 110 (4.33) MEASUREMENT ACCURACY EL-USB-1-PRO Accuracy 1.8 1.6 Accuracy ±°C 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 -40 -20 0 20 40 60 80 100 120 Temperature °C BATTERY REPLACEMENT We recommend that you replace the battery every 18 months, or prior to logging critical data. The EL-USB-1-PRO does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Only use an EL-USB-1-PRO battery that is supplied or recommended by Lascar, which is rated for use in high temperatures and has the correct battery terminals. Using non-Lascar batteries may result in fire or explosion at high temperatures. Suitable batteries are: Tadiran TLH-5955/S and Tadiran SL-561/S. Note: Leaving the EL-USB-1-PRO plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. www.lascarelectronics.com Specifications liable to change without prior warning Issue 7 07/2012 S.L Applies to EL-USB-1-PRO Page 2 of 3 EL-USB-1-PRO Temperature Data Logger with Extended Range THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-USB connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: Part No Function Accuracy (overall error) Range Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature -35 to +80°C (-31 to +176°F) ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD -35 to +80°C (-31 to +176°F) ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to +125°C (-40 to +257°F) ±0.2ºC (±0.4ºF) ±0.5ºC (±1ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG Temperature with rechargeable battery 32,510 Lithium Ion 1 month (rechargeable) EL-USB-2 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year -20 to +60°C (-4 to +140°F) ±1ºC (±2ºF) Temperature, humidity & dew point -35 to +80°C (-31 to +176°F) ±0.5ºC (±1ºF) ±2ºC (±4ºF) ±3%RH ±6.0%RH EL-USB-2+ Increased accuracy temperature, humidity & dew point -35 to +80°C (-31 to +176°F) ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) ±2.0%RH ±4.0%RH EL-USB-2-LCD Temperature, humidity & dew point with LCD -35 to +80°C (-31 to +176°F) ±0.5ºC (±1ºF) ±2ºC (±4ºF) ±3.0%RH ±6.0%RH EL-USB-2-LCD+ Increased accuracy temperature, humidity & dew point with LCD -35 to +80°C (-31 to +176°F) ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) 0 to 100%RH ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A 32,510 3.6V ½AA 1 year ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months 0 to 100%RH 0 to 100%RH 0 to 100%RH ±3 secs/24 hrs -200 to +1350ºC (-328 to +2462ºF) (K-type) EL-USB-TC Thermocouple (J, K and Ttype) K-type probe included -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) -200 to +1350ºC (-328 to +2462ºF) (K-type) EL-USB-TC-LCD Thermocouple with LCD (J, K and T-type) K-type probe included EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months 4,080 CR1620 1 month N/A N/A -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) EL-USB-LITE Low cost temperature -10°C to +50°C (+14 to +122°F) EL-USB-RT Real-time temperature & humidity monitor -20 to +70°C (-4 to +158°F) ±1ºC (±2ºF) ±1.5ºC (±3ºF) 7 days ±4.5%RH Lithium coin cell *Depending on logging rate, ambient temperature, and use of alarm LED 4258 West 12th Street Erie PA 16505 USA T +1 (814) 835 0621 F +1 (814) 838 8141 E us-sales@lascarelectronics.com Module House Whiteparish, Salisbury Wiltshire SP5 2SJ UK T +44 (1794) 884567 F +44 (1794) 884616 E sales@lascar.co.uk 8th Floor, China Aerospace Centre 143 Hoi Bun Road Kwun Tong, Kowloon HONG KONG T +852 2797 3219 F +852 2343 6187 E saleshk@lascar.com.hk www.lascarelectronics.com Specifications liable to change without prior warning Issue 7 07/2012 S.L Applies to EL-USB-1-PRO Page 3 of 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51 Instance ID : uuid:d8fe7537-1dac-4764-94b5-ad06875c0730 Document ID : adobe:docid:indd:ab440e47-0a34-11de-b422-9e5bc0d0bb60 Original Document ID : adobe:docid:indd:ab440e47-0a34-11de-b422-9e5bc0d0bb60 Rendition Class : proof:pdf Derived From Instance ID : c8187186-0417-11de-a0ad-ff28ab9aef21 Derived From Document ID : adobe:docid:indd:092e88a9-ca93-11dd-9654-e171c6daf48c History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:EBBA69883772DF11B168C65007C21342, xmp.iid:ECBA69883772DF11B168C65007C21342, xmp.iid:EDBA69883772DF11B168C65007C21342, xmp.iid:3026CD383F8BDF119DD5AB2887E6D9BA, xmp.iid:5745B08B9B8DDF11B52ECA50EB3FA4A9, xmp.iid:5845B08B9B8DDF11B52ECA50EB3FA4A9, xmp.iid:B1BE31F2C18DDF11AA18E8F8158612E9, xmp.iid:BDD7108B5899DF118EE5962260CA38E4, xmp.iid:220251139FB5DF1194EBBDADE3D37351, xmp.iid:36CF718FC044E011B9D3E23A86D77E0F, xmp.iid:E8B8A662F0C7E0119747D986C2967537, xmp.iid:E9B8A662F0C7E0119747D986C2967537, xmp.iid:EAB8A662F0C7E0119747D986C2967537, xmp.iid:EBB8A662F0C7E0119747D986C2967537, xmp.iid:A03B0D0BD332E111BA0EF559B33B7210, xmp.iid:A13B0D0BD332E111BA0EF559B33B7210, xmp.iid:C3EBBBD131D7E11184B686DD8FC99349 History When : 2010:06:07 14:45:12+01:00, 2010:06:07 14:45:12+01:00, 2010:06:07 14:46:48+01:00, 2010:07:09 16:51:40+01:00, 2010:07:12 11:01:13+01:00, 2010:07:12 11:05:44+01:00, 2010:07:12 15:29:57+01:00, 2010:07:27 09:54:21+01:00, 2010:09:01 09:12:44+01:00, 2011:03:02 13:35:52Z, 2011:08:16 11:31:16+01:00, 2011:08:16 11:31:37+01:00, 2011:08:16 11:43:29+01:00, 2011:08:16 11:52:06+01:00, 2011:12:30 10:43Z, 2011:12:30 10:43Z, 2012:07:26 15:54:36+01:00 History Software Agent : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 7.5, Adobe InDesign 7.5, Adobe InDesign 7.5 History Changed : /, /metadata, /, /, /, /, /, /, /, /, /, /, /, /, /;/metadata, /metadata, /;/metadata Create Date : 2012:07:26 15:54:44+01:00 Modify Date : 2012:07:26 15:54:46+01:00 Metadata Date : 2012:07:26 15:54:46+01:00 Creator Tool : Adobe InDesign CS5.5 (7.5.3) Page Image Page Number : 1, 2 Page Image Format : JPEG, JPEG Page Image Width : 256, 256 Page Image Height : 256, 256 Page Image : (Binary data 10434 bytes, use -b option to extract), (Binary data 8468 bytes, use -b option to extract) Doc Change Count : 267 Format : application/pdf Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 3 Creator : Adobe InDesign CS5.5 (7.5.3)EXIF Metadata provided by EXIF.tools