FL 30 Manual

User Manual: Pdf

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadFL-30-Manual
Open PDF In BrowserView PDF
FL-30 Laser Distance Meter
User Manual

User manual
English
Congratulations on the purchase of this product.
Carefully read the safety instructions and the user manual before using
this product.
The person responsible for the instrument must ensure that all users understand these
directions and adhere to them.

Contents

1. Safety Instructions ................................................................ 2
2. Start-up.................................................................................. 5
3. Menu Functions .................................................................... 5
4. Operation .............................................................................. 6
5. Measuring ............................................................................. 7
6. Functions............................................................................... 7
7. Appendix ............................................................................... 8
8. Technical data ....................................................................... 9
9. Measuring conditions ......................................................... 10

1

1. Safety

Instructions

Symbols Used
The following symbols are used to distinguish precautions by the degree of injury or
damage that may result if the precaution is ignored.

Warning
Caution
Important paragraphs, which must be adhered to

Use of the instrument
a) Press
meter.

to switch on the device. The laser beam emits from the front of the

b) Press

again to measure the distance. The results will show on the screen.

Cautions:
-Do not look straight at the laser beam
-Do not use the device in flammable and explosive environments
-Remove the batteries to avoid leakage if the device is not to be used for a long period
of time

Care
Wipe off dirt with a damp, soft cloth or a clean cloth moistened with alcohol. Be
careful with the optical components (such as optical lens): wipe with a clean soft cloth
or cotton swab moistened with distilled water (same as cleaning glass or camera lens).
Do not use aggressive cleaning agents or solutions.

Permitted use
Measuring distances, areas and volumes

2

Prohibited use
-Using the instrument without instruction
-Using outside the stated limits
-Deactivation of safety systems and removal of explanatory and hazard labels.
-Opening of the equipment by using tools (screw drivers. etc.), as far as not
specifically permitted for certain cases.
-Carrying out modification or conversion of the product
-Use of accessories from other manufacturers without the approval of our company.

Limits of use
See section “Technical Data”

Responsibilities of the person in charge of the instrument
Warning:
The person responsible for the instrument must ensure that the equipment is
used correctly and is responsible for training and safety of the equipment when in use.
The person in charge of the instrument has the following duties:
-To understand the safety instructions of the product and the instructions in the user
manual.
-To be familiar with local safety regulations relating to accident prevention
-To inform local dealer immediately if the equipment becomes unsafe.

Hazards in use
Caution:
Watch out for incorrect distance measurements. If the instrument is defected or if it
has been dropped or has been misused or modified.

Precautions:
-Carry out periodic test measurements, particularly after the instrument has been
subject to abnormal use, and before, during and after important measurement.
-Make sure the optics are kept clean and undamaged

Caution:
If the instrument is used for positioning moving objects (e.g. cranes, building
3

equipment, platforms, etc.) unforeseen events may cause invalid measurements

Warning:
Flat batteries must not be disposed of with household waste.
The product must not be disposed of with household waste.
Take them to the collection points provided in accordance with national or local
regulations.

Electromagnetic compatibility (EMC)
The term” electromagnetic compatibility” means the capability of the product to
function smoothly in an environment where electromagnetic radiation and
electrostatic discharges are present, and without causing electromagnetic interference
to other equipment.

Warning:
The product conforms to the most stringent requirements of the relevant standards and
regulations. Yet, the possibility of it causing interference in other devices cannot be
totally excluded.

Caution:
Never attempt to repair the product yourself. In case of damage, contact ATP
Instrumentation Ltd

Laser classification
Integrated distance meter

This product produces a visible laser beam, which emits from the front of the
instrument.
It is a class 2 laser product in accordance with:
4

IEC60825-1:2007 “Radiation safety of laser products” laser class 2 products:
Do not stare into the laser beam or direct it towards other people.

Warning:
Looking directly into the beam with optical aids (e.g. binoculars telescopes) can be
hazardous.

Precautions:
Do not look directly into the beam with optical aids.

Caution:
Looking into the laser beam may be hazardous to the eyes.

Precautions:
Do not look into the laser beam. Make sure the laser is aimed above or below eye
level.

2. Start-up
2-1 inserting/replacing batteries
1). Remove battery compartment lid and attach hand strap
2). Insert batteries
3). Close the battery compartment
Replace the batteries when the

symbol flashes permanently in the display.

Remove the batteries when the meter is not going to be used for a long
period of time to avoid the danger of corrosion
Only use alkaline or rechargeable batteries

3. Menu Functions
3-1. Changing unit of measurement
Press

to turn the meter on and press and hold
5

for a while to

change the unit of distance measurement. The following units are available: m (meter),
ft (feet), in (inch), ftin (feet-inch 1/16) or ruler
3-2 Turn on the laser
To turn the laser on, press

button.

Aim the laser at a target and press
measurement result.
Press

button again. Display shows

button to clear the measurement and turn the laser off.

3-3 Screen Change
Press

together to change the direction of the screen display

4. Operation
4-1 Switching the meter on/off
Press

to turn the instrument and laser on. The display shows the battery

symbol until

is pressed again.

Press and hold
button to turn the instrument off
The instrument switches off automatically after three minutes of no activity.
4-2. Clear Button
Press
button to cancel the last action. While making area or volume
measurements, each single measurement can be deleted and re-measured in
succession.
4-3 Reference Setting
The default reference setting is from the rear of the instrument. Press
display will show you.

Press

the

button, will measure the reference edge

fixed to the front. The display will show you.
6

Press the
button, the rear reference is set again.
Press the two arrowed button on the base of the meter to pull out the belt buckle and
turn it the other way round to extend the length of the device, you can measure from
the corner. Press this button

, a measurement will be extended along as the

reference edge, the display will show you.

5. Measuring
5-1 Single Distance Measurement
Press
to activate the laser. Press
measurement. The result is displayed immediately.
5-2. Continuous Measurement
Press and hold down
measurements. Press

again to trigger the distance

button for 2 seconds to make continuous
again to stop continuous measurement.

6. Functions
6-1 Area
Press
Press the
Press

once to enter into area mode.
button to take the first length measurement (e.g. length).
again to take the second length measurement(e.g. width). The result
7

is displayed in the summary line.
6-2 Volume
Press

button twice to enter into volume mode.

Press

button to take the first measurement (e.g.length).

Press

button to take the second measurement (e.g.width)

Press
button to take the third measurement (e.g.height)
The volume result appears in the summary line.

7. Appendix
7-1 Message Codes
Icon

Cause
Solution
Calculation error. Signal is Reoperation, change to a better
too weak or too strong, or surface or use a target plate
measurement time is too
long.

Ambient light is too strong

Change the light for measuring

Temperature is too high Cool down or warm up the
(+40°C) or too low (0°C)
instrument. This instrument works
best at temperatures between 0°C
to +40°C
Switch on/off the instrument
several times. If the symbol still
appears, then your instrument
Hardware error
may be defective. Please call ATP
Instrumentation
Ltd
for
assistance.

8

8. Technical Data
0.05~30m
±2mm
1mm
Class 2
2
620~690nm,<1mw 0.16x0.6 mrad,0.25s
yes
yes
yes
IP54
0~40°C
-20~70°C
5000 Measurements
LR3(AAA)2x1.5v
After 30 seconds
After 3 minutes
118*37*25mm
70g
Max Relative Humidity :0~95%

Measuring Range
Measuring Accuracy
Display Accuracy
Laser Classification
Pollution Degree
Laser Type
Area, Volume Measuring
Continuous Measuring
Show Beep
Protection against splashes and dust
Temperature range for operation
Temperature range for storage
Battery Life
Battery Selection
Laser Switch-off Automatically
Instrument Switch-off Automatically
Dimensions
Weight
Max Operating Altitude:2000m:

Use a target plate to increase the measurement range during daylight or if the target
has poor reflection properties.
Measurement accuracy could reach ±2mm in good conditions (good measurement
surface, room temperature). If under adverse measuring conditions, such as the light is
too strong, the temperature difference is too large, or the measured surface reflection
is too weak, the deviation over distance will increase.

9

9. Measuring Conditions
9-1 Measuring Range
The range of this meter is limited to 30m, at night or dusk and if the target is in
shadow, the measuring range without target plate is increased. Use a target plate to
increase the measurement range during daylight or if the target has poor reflection
properties.
9-2 Target Surfaces
Measuring errors can occur when measuring toward colorless liquids (e.g. water) or
dust free glass, Styrofoam or semipermeable surfaces. Aiming at high gloss surfaces
may deflect the laser beam and lead to measurement errors. For non-reflective and
dark surfaces the measuring time may increase.
-if the equipment is used in a manner not specified by the manufacture, the warranty
will be invalid

Care
Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth. Do not
use aggressive cleaning agents or solutions. Handle the instrument as you would a
telescope or camera.

Warranty
This instrument comes with a one-year warranty. If it is not used correctly via this
manual, the warranty will be invalid.

10

UK DISTRIBUTOR

ATP INSTRUMENTATION LTD
TOURNAMENT WAY
ASHBY DE LA ZOUCH
LEICESTERSHIRE
LE65 2UU

TEL 01530 566800
FAX 01530 560373

WWW.ATP-INSTRUMENTATION.CO.UK

11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 12
Page Layout                     : OneColumn
Page Mode                       : UseNone
Producer                        : doPDF Ver 7.2 Build 367 (Windows 7 Business Edition (SP 1) - Version: 6.1.7601 (x86))
Create Date                     : 2016:06:23 14:26:17Z
EXIF Metadata provided by EXIF.tools