31 51790 GE Refrig Tech Sheet

2013-04-09

: Pdf Ge Refrig Tech Sheet - 31-51790 GE Refrig Tech Sheet - 31-51790 GE, Camco, Hotpoint, Mofat

Open the PDF directly: View PDF PDF.
Page Count: 2

Technical Data
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a
major appliance may result in personal injury and
property damage. The manufacturer or seller cannot be
responsible for the interpretation of this information, nor
can it assume any liability in connection with its use.
1663B
INSTALLATION
Clearance must be provided for air circulation
At Top ................................................................................................................................................1" (25 mm)
At Sides......................................................................................................................................0.13" (3.3 mm)
At Rear ..............................................................................................................................................1" (25 mm)
197D4106P104
AIRFLOW
ELECTRICAL SPECIFICATIONS
Thermistor calibration:
kilo-ohm resistance ........................................................................ @ 0°F (-18°C) 42.5k ohms
...................................................................................................................... @ 37°F (3°C) 14.0k ohms
....................................................................................................................@ 77°F (25°C) 4.92k ohms
Defrost Control .............................................................................................................. Adaptive System
Overtemperature Thermostat ....................................................................140°–110°F (60°–43°C)
ELECTRICAL RATING
Maximum Current Leakage ....................................................................................................... 0.75 mA
Maximum Ground Path Resistance ..................................................................................0.14 Ohms
NO LOAD PERFORMANCE
Control Position 5/5 and Ambient of 65°–90°F (21°–32°F)
Fresh Food .................................................................................................................. 34°–41°F (1° to 5°C)
Frozen Food .......................................................................................................-3° to 3°F (-19° to -16°C)
Run Time, % @ 65°F (21°C) Ambient ....................................................................................... 23 to 35
Run Time, % @ 90°F (32°C) Ambient ....................................................................................... 48 to 60
Run Time, % @ 65°F (21°C) Ambient (Variable Speed) .............................................................<75
Run Time, % @ 90°F (32°C) Ambient (Variable Speed) .................................................75 to 100
REFRIGERATION SYSTEM 25' 22'/20'
Refrigerant Charge See Rating Plate See Rating Plate
Compressor (Single Speed) 900–980 BTU/hr 800 BTU/hr
(Global 956 BTU/hr) (Global 956 BTU/hr)
Compressor (Variable Speed) 833 BTU/hr @ 3000 833 BTU/hr @ 3000
Minimum Compressor Capacity 21"–26" Hg 21"–26" Hg
Minimum Equalized Pressure
@ 65°F (21°C) 55 psig (370KPa) 55 psig (370KPa)
@ 90°F (32°C) 63 psig (434KPa) 63 psig (434KPa)
Minimum Equalized
Pressure (Variable Speed)
@ 70°F (21°C) 45–48 psig (310–331KPa) 45–48 psig (310–331KPa)
@ 90°F (32°C) 54–60 psig (372–413KPa) 54–60 psig (372–413KPa)
FREEZER
EVAPORATOR
FRESH FOOD
COLD AIR MIXED AIR WARMER AIR
.110" Hub to To p
of Orifice
SXS - 25/22/20
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original position and properly fastened.
197D4106P104 31-51790 04-09 JR
1663B
197D4106P104
SXS - 25/22/20
C.M OT .
WIRING
ORANGE
WHITE
WHITE
RUN CAPACITOR
ORANGE
TO AC
AF RESNEDNOC N
BLACK
BLACK
ORANGE
RELAY
OVERLOAD
WOLLEY/NEERG
TO IM & AUGER
MOTOR
GREEN/
YELLOW
PURPLE/
BLACK BROWN
WHITE
BLACK/
WHITE
ORANGE
TO
CONDENSER
FAN
RED
OPEN WHITE
YELLOW
PINK
BLUE
DEFROST
HEATER
FZ SENSOR
ELECTRONIC
BOARD
OVERTEMPERAT URE
THERMISTOR
ORANGE
PINK
EVAPORAT OR
SENSOR
WHITE
TO THERMOSTAT
& EVAP SENSOR
TO EVAP FAN
& LIGHT
RED
YELLOW/
BLACK BLUE
RED
ORANGE
TEST
POINT
TO COMM FZ
DOOR HARNESS
TEMPERATURE CONTROLS
FZ SW FF SW
FF DAMPER
FF SENSOR
WHITE/
YELLOW
BLUE/
WHITE
FRESH FOOD LAMP
(WHEN APPLICABLE)
PURPLE
ORANGE
05M-1515A
WHITE
ICEMAKER
VA LVE
DISPENSER
WATER
VA LVE
ORANGE
ORANGE
BLACK
YELLOW
BROWN
POWER
CORD
TO MACHINE
WIRING
FERRITE BEAD
GROUND
WIRE
ORANGE
ORANGE
GRAY
GRAY
RED
BROWN
RECESS
HEATER
PA D
SWITCH
YELLOW
DUCT
DOOR
SOLENOID
RED
ORANGE
P1
P2
P1 P2
1 TA N
2 RED
3 BLACK
4 VIOLET
5 WHITE
6 BLACK/WHITE
1 NOT USED
2 YELLOW
3 RED
4 GRAY
DISPENSER
LIGHT
WHEN
USED
CONTROL
MODULE
TO CABINET
WIRING

Navigation menu