HCS UL1008BCELTS1277 Spec Sheet
2018-07-28
: Pdf Hcs Ul1008Bcelts1277 Spec Sheet HCS_UL1008BCELTS1277_Spec_Sheet spec products hba
Open the PDF directly: View PDF .
Page Count: 2
Emergency Lighting Control
1
Project Name
Catalog No. Date
6005A 072418
701 Millennium Blvd. | Greenville, SC 29607 | (864) 678-1000 | (866) 898-0131 - fax www.hubbellcontrolsolutions.com
Copyright © 2018 Hubbell Control Solutions, a division of Hubbell Lighting, Inc. All rights reserved. All product and company names, logos and product
identiers are trademarks ™ or registered trademarks ® of Hubbell Lighting, Inc. or their respective owners. Use of them does not necessarily imply any
aliation with or endorsement by such respective owners.
Branch Circuit Emergency Lighting Control Transfer Switch
The UL1008BCELTS1277 is specically listed for branch circuit
emergency lighting control under the new UL standards. This unit
is intended for applications where both a normal and emergency
branch circuit are to be connected to the emergency lighting. The
UL1008BCELTS1277 automatically transfers from normal to emergency
power source upon loss of normal power in the space.
The UL1008BCELTS1277 allows emergency lighting to be dimmed
with normal lighting during normal times. In the event of a utility
power interruption, the UL1008BCELTS1277 will automatically transfer
designated emergency xtures from the dimming control to the
emergency power source and bring them to full brightness, regardless
of whether the dimming system is in operation or turned o.
• UL1008 listed for transfer of branch circuits
• Transfer includes neutral wire
• Compatible with all dimming systems
• Integral front mounted test switch
• Fire alarm interface option
• Safety interlock system prevents cross connection
• 50A relay contacts allow for high inrush loads
• Suitable for ush or surface mounting
• Works with both inverter and generator systems
Product Features
Ordering Information
Dimensional Data
MODEL
UL1008BCELTS1277 Branch circuit emergency transfer switch, 120/277 VAC
UL1008BCELTS1277
6"
(152.4 mm)
6"
(152.4 mm)
0.5"
(12.7 mm)
4.3"
(109.2 mm)
1.9"
(48.3 mm)
Compliance and Certication
26005A 072418
701 Millennium Blvd. | Greenville, SC 29607 | (864) 678-1000 | (866) 898-0131 - fax www.hubbellcontrolsolutions.com
Copyright © 2018 Hubbell Control Solutions, a division of Hubbell Lighting, Inc. All rights reserved. All product and company names, logos and product
identiers are trademarks ™ or registered trademarks ® of Hubbell Lighting, Inc. or their respective owners. Use of them does not necessarily imply any
aliation with or endorsement by such respective owners.
Emergency Lighting Control Branch Circuit Emergency Lighting Control Transfer Switch
Wiring Diagrams
Normal
Utility Power
Normal
Utility Power
Emergency
Power Source
(Neutral Not Shown)
UL 1008
Transfer Switch
or Equivalent
EMERGENCY
PANEL OR
INVERTER
NORMAL
PANEL
UL1008BCELTS1277UL1008BCELTS1277
DESIGNATED
EMERGENCY
LIGHTS
20A EMERGENCY HOT
EMERGENCY
PANEL OR
INVERTER
EMERGENCY NEUTRAL NORMAL NEUTRAL
NORMAL HOT 20A
NORMAL
PANEL
Note: Emergency Light is also called
N/E LIght or Normal/Emergency
Light by many speciers
Note: Typical 2-Wire Dimming shown.
Please see installation instructions for
3-wire and 0-10V wiring diagrams
Note: Dimmer may be a stand-alone dimmer, multi-zone dimmer
(such as Grak Eye), or central dimming panel. One UL1008BCELTS1277
is required per dimming zone with emergency lighting.
Red Fire Alarm Jumper
(see additional resources)
Normal Light (optional)
EMERGENCY
LIGHTING
UTILITY
POWER
EMERGENCY
POWER
TEST SWITCH
NORMAL
ROOM
LIGHTS
Normal
Utility Power
Normal
Utility Power
Emergency
Power Source
(Neutral Not Shown)
UL 1008
Transfer Switch
or Equivalent
EMERGENCY
PANEL OR
INVERTER
NORMAL
PANEL
UL1008BCELTS1277UL1008BCELTS1277
DESIGNATED
EMERGENCY
LIGHTS
20A EMERGENCY HOT
EMERGENCY
PANEL OR
INVERTER
EMERGENCY NEUTRAL NORMAL NEUTRAL
NORMAL HOT 20A
NORMAL
PANEL
Note: Emergency Light is also called
N/E LIght or Normal/Emergency
Light by many speciers
Note: Typical 2-Wire Dimming shown.
Please see installation instructions for
3-wire and 0-10V wiring diagrams
Note: Dimmer may be a stand-alone dimmer, multi-zone dimmer
(such as Grak Eye), or central dimming panel. One UL1008BCELTS1277
is required per dimming zone with emergency lighting.
Red Fire Alarm Jumper
(see additional resources)
Normal Light (optional)
EMERGENCY
LIGHTING
UTILITY
POWER
EMERGENCY
POWER
TEST SWITCH
NORMAL
ROOM
LIGHTS
Schematic Wiring Diagram
Wire Termination Diagram
General Specications
Electrical
Sensing Input 120V-277V
Load Rating 120V-277V (16A)
Ballast Load Rating 16A Magnetic/ 16A Electronic
Incandescent Load 1920W (120V) / 4432W (277V)
Mechanical
Mounting 4-11/16" Back-up Box, no plater ring required
Rating UL94V-0
Shipping Weight 18 oz.
Color White
Certications UL1008 Listed
Temperature 32°F - 140°F (0°C - 6°C)
Warranty 5 Year Replacement Warranty