KX83101

2013-09-19

: Pdf Kx83101 KX83101 pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadKX83101
Open PDF In BrowserView PDF
HEATING

Drain Easy Kit

A valuable time-saving kit to avoid system draining for repairs and replacements on open vented ‘wet’ central heating systems

Invensys Controls

Part of the Invensys Group

Drain Easy kit
Features

Fitting

The Drayton Drain Easy kit comprises two
durable rubber plugs, a tie and a radiator
bleed key.

The specially-shaped Drain Easy plugs are fitted into the cold feed and the
expansion pipe of the feed and expansion tank.

It is designed to facilitate removal of valves,
repair of leaks etc. on an open vented wet
central heating system without draining
down, consequent loss of inhibitor, and risk
of major air locks during refilling. It can only
be used where the header (feed and
expansion) tank is no more than 30ft (9
metres) above the lowest point in the
system and only one break in the system is
being made at a time.
The most important benefit of using the
Drain Easy kit is to allow easy replacement
of standard radiator valves with energysaving TRVs. Thermostatic radiator valves
such as the Drayton TRV4 offer substantial
reductions in running costs over normal
valves, coupled with improved comfort as
room temperatures may be set individually.
It is also a valuable emergency kit which will
allow various repair and maintenance jobs
such as the replacement of failed pipes,
valves, radiators etc. to be undertaken
quickly and easily.

Drain
easy
plugs

After releasing some inherent pressure in the system with the bleed key supplied,
and building up a vacuum by allowing water to flow for about 1 minute, any
single item such as a pump, valve or radiator may be removed without further
loss of system water/inhibitor.

Specification
Kit contents	
	

Two Rubber male plugs, radiator bleed key, 1m tiecord,
full instructions.

Materials	
	

Plugs: Ethylene propylene
Bleed key: Brass stamping

Limitations	

Suitable for 15mm and 22mm pipework.

	
	

Not to be used on direct, unvented or primatic systems or
auto-vented systems.

	
	

Not to be used on systems with a header tank more than
30ft (9 metres) above the systems lowest point.

	

No lubricating oils to be applied.

	
	

Only one section of pipework can be disconnected at a time
e.g. No three-way valves – one two-way disconnection only.

Available from:
Customer Service Tel: 0845 130 5522
Customer Service Fax: 0845 130 0622
Technical Helpline Tel: 0845 130 7722
Email: customer.care@invensys.com
Website: www.draytoncontrols.co.uk

D19-8

In accordance with our continuous improvement procedures, we reserve the right to change design features and specifications without prior notification. The Data contained in this document is for guidance only. Invensys Controls
Europe accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:05:41
Instance ID                     : uuid:eb08e359-858c-1344-92ca-f4f7d56eda09
Document ID                     : adobe:docid:indd:ff252cde-f00d-11dd-9242-bd49eb5456e4
Original Document ID            : adobe:docid:indd:ff252cde-f00d-11dd-9242-bd49eb5456e4
Rendition Class                 : proof:pdf
History Action                  : saved, saved, saved, saved
History Instance ID             : xmp.iid:840074010B206811BEDCB23FD79E8DF5, xmp.iid:850074010B206811BEDCB23FD79E8DF5, xmp.iid:C3A337900E206811BEDCB23FD79E8DF5, xmp.iid:3129865B35206811BEDCB23FD79E8DF5
History When                    : 2010:03:24 11:36:17Z, 2010:03:24 11:36:17Z, 2010:03:24 12:02:28Z, 2010:03:24 16:44:42Z
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /, /
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:1336B6E6C6F4DD11A428FCBF902DC549, uuid:D628506CBBF3DD11B91BFEEE9D99052E, uuid:541e7b89-4ad0-11d9-a3eb-da55a2dde124
Manifest Reference Document ID  : uuid:1236B6E6C6F4DD11A428FCBF902DC549, uuid:D528506CBBF3DD11B91BFEEE9D99052E, adobe:docid:photoshop:541e7b86-4ad0-11d9-a3eb-da55a2dde124
Create Date                     : 2010:03:30 15:11:28Z
Modify Date                     : 2010:03:30 15:11:33Z
Metadata Date                   : 2010:03:30 15:11:33Z
Creator Tool                    : Adobe InDesign CS4 (6.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8415 bytes, use -b option to extract)
Doc Change Count                : 5
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS4 (6.0.4)
EXIF Metadata provided by EXIF.tools

Navigation menu