DE112459T1 LVD Certificate And Report

2016-04-11

: Pdf Lvd Certificate And Report LVD_Certificate_and__report CertsReports 520416 ProductFiles

Open the PDF directly: View PDF PDF.
Page Count: 62

DownloadDE112459T1  LVD Certificate And Report
Open PDF In BrowserView PDF
Page 3 of 56

Report No.: DE112459

List of Attachments (including a total number of pages in each attachment):
Page 1 to 56 for test report
Appendix 1 to 5 for product photographs
Summary of testing:

Tests performed (name of test and test clause):
The sample(s) tested complies with the
requirements of EN 60950-1:2006+ A11:2009+
A1:2010+A12:2011+A2:2013

Testing location:
68 Fumin Nan Road, Dalang, Dongguan City,
Guangdong Province, P.R. China

Summary of compliance with National Differences
List of countries addressed: EU
The product fulfils the requirements of EN 60950-1:2006+ A11:2009+ A1:2010+A12:2011+A2:2013
Copy of marking plate:

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 4 of 56

Report No.: DE112459

Test item particulars.................................................. : 24-Port Fast Ethernet Rackmount Switch
Equipment mobility ................................................ : [x] movable [] hand-held
[] transportable
[] stationary
[] for building-in [] direct plug-in
Connection to the mains ........................................ : [x] pluggable equipment
[x] type A [] type B
[] permanent connection
[x] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
Operating condition ................................................ : [x] continuous
[] rated operating / resting time:
Access location ...................................................... : [x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................ : [] OVC I [x] OVC II [] OVC III
[] other
Mains supply tolerance (%) or absolute mains
+10%, -10%
supply values .......................................................... :
Tested for IT power systems ................................. : [] Yes [x] No

[] OVC IV

IT testing, phase-phase voltage (V) ...................... : N/A
Class of equipment ................................................ : [] Class I
[x] Class II
[] Class III
[] Not classified
Considered current rating of protective device as 16A
part of the building installlation (A) ...................... :
Pollution degree (PD) ............................................. : [] PD 1 [x] PD 2 [] PD 3
IP protection class ................................................. : IPX0
Altitude during operation (m) ................................ : 2000
Altitude of test laboratory (m) ............................... : < 2000
Mass of equipment (kg) ......................................... : 1.43kg
Possible test case verdicts:
- test case does not apply to the test object ...........: N (N/A)
- test object does meet the requirement ..................: P (Pass)
- test object does not meet the requirement ...........: F (Fail)
Testing..........................................................................:
Date of receipt of test item.........................................: 2014-08-20; 2014-10-16; 2014-10-22
Date(s) of performance of tests ................................: 2014-08-20 to 2014-09-09; 2014-10-16; 2014-10-22

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 5 of 56

Report No.: DE112459

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a

comma /

point is used as the decimal separator.

Page 1 to 56 for test report
Appendix 1 to 6 for product photographs
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:

When differences exist; they shall be identified in the General product information section.
General product information:
The submitted unit is 24-Port Fast Ethernet Rackmount Switch. It supplied by minas via a detachable
power supply cord
The max operated temperature is 50°C which is specified by manufacturer.
Abbreviations used in the report:
- normal conditions
- functional insulation
- double insulation
- between parts of opposite
polarity

N.C.
OP
DI
BOP

- single fault conditions
- basic insulation
- supplementary insulation
- reinforced insulation

Indicate used abbreviations (if any)

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

S.F.C
BI
SI
RI

Page 6 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

1

GENERAL

P

1.5

Components

P

1.5.1

General

P

Comply with IEC 60950-1 or relevant component
standard

Result - Remark

see appended table

Verdict

P

1.5.2

Evaluation and testing of components

1.5.3

Thermal controls

Not used

N

1.5.4

Transformers

See Annex C

P

1.5.5

Interconnecting cables

No hazards

P

1.5.6

Capacitors bridging insulation

Capacitor CX1, CY1, CY2
and CY3 used

P

1.5.7

Resistors bridging insulation

No such resistors

N

1.5.7.1

Resistors bridging functional, basic or supplementary
insulation

N

1.5.7.2

Resistors bridging double or reinforced insulation
between a.c. mains and other circuits

N

1.5.7.3

Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable

N

1.5.8

Components in equipment for IT power systems

Not for IT power distribution
systems

N

1.5.9

Surge suppressors

Varistor VZ1 was approved

P

1.5.9.1

General

See Annex Q

P

1.5.9.2

Protection of VDRs

Fuse F1 used

P

1.5.9.3

Bridging of functional insulation by a VDR

P

1.5.9.4

Bridging of basic insulation by a VDR

N

1.5.9.5

Bridging of supplementary, double or reinforced
insulation by a VDR

1.6

Power interface

1.6.1

AC power distribution systems

TN

P

1.6.2

Input current

(see appended table 1.6.2)

P

1.6.3

Voltage limit of hand-held equipment

Not hand-held equipment

N

1.6.4

Neutral conductor

N

1.7

Marking and instructions

P

1.7.1

Power rating and identification markings

1.7.1.1

Power rating marking

P

Multiple mains supply connections..........................:

N

Rated voltage(s) or voltage range(s) (V) ...............:
TRF No. IEC60950_1B_M2

P

No such Varistor

N

P

See below

100-240V

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

P

Page 7 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

1.7.1.2

Requirement + Test

Result - Remark

Verdict

Symbol for nature of supply, for d.c. only ...............:

AC input

N

Rated frequency or rated frequency range (Hz) ....:

50/60Hz

P

Rated current (mA or A) ........................................:

Max. 0.5A

P

Identification markings

See copy of marking plate

P

Manufacturer’s name or trade-mark or identification
mark .......................................................................:

Intellinet

P

Model identification or type reference ....................:

520416

P

Symbol for Class II equipment only........................:

Class I

N

Other markings and symbols .................................:

Additional symbol or marking
does not give rise to
misunderstanding.

P

1.7.1.3

Use of graphical symbols

P

1.7.2

Safety instructions and marking

P

1.7.2.1

General

P

1.7.2.2

Disconnect devices

1.7.2.3

Overcurrent protective device

N

1.7.2.4

IT power distribution systems

N

1.7.2.5

Operator access with a tool

N

1.7.2.6

Ozone

No ozone radiation

N

1.7.3

Short duty cycles

Continuous operation

N

1.7.4

Supply voltage adjustment ...................................:

N

Methods and means of adjustment; reference to
installation instructions .........................................:

N

Mains plug and appliance
coupler as disconnect divices

N

1.7.5

Power outlets on the equipment ...........................:

No such power outlets

N

1.7.6

Fuse identification (marking, special fusing
characteristics, cross-reference) ..........................:

F1: T1.0AL250VAC

P

1.7.7

Wiring terminals

1.7.7.1

Protective earthing and bonding terminals ...........:

1.7.7.2

P
P

Terminals for a.c. mains supply conductors

on inlet
No such terminal provided

N

1.7.7.3

Terminals for d.c. mains supply conductors

No d.c. mains

N

1.7.8

Controls and indicators

P

1.7.8.1

Identification, location and marking ......................:

N

1.7.8.2

Colours ................................................................:

1.7.8.3

Symbols according to IEC 60417 .........................:

P

1.7.8.4

Markings using figures .......................................:

P

1.7.9

Isolation of multiple power sources .....................:

N

1.7.10

Thermostats and other regulating devices ..........:

No such adjustable devices

N

1.7.11

Durability

Legible after test

P

TRF No. IEC60950_1B_M2

No colour impairs safety

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 8 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

1.7.12

Removable parts

No such parts

N

1.7.13

Replaceable batteries ..........................................:

No such battery

N
⎯

Language(s) ........................................................:
1.7.14

Equipment for restricted access locations............:

Not for installation in
restricted access locations

N

2

PROTECTION FROM HAZARDS

P

2.1

Protection from electric shock and energy hazards

P

2.1.1

Protection in operator access areas

P

2.1.1.1

Access to energized parts

Cannot touch live part and
basic insulation

P

Test by inspection ..................................................:

No hazards

P

Test with test finger (Figure 2A) ............................:

No hazards

P

Test with test pin (Figure 2B) ................................:

No hazards

P

Test with test probe (Figure 2C) ............................:

No hazards

P

2.1.1.2

Battery compartments

No compartments

N

2.1.1.3

Access to ELV wiring

No ELV circuit

N

Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)

⎯

2.1.1.4

Access to hazardous voltage circuit wiring

N

2.1.1.5

Energy hazards .....................................................:

(see appended tables 2.1.1.5)

P

2.1.1.6

Manual controls

No manual control

N

2.1.1.7

Discharge of capacitors in equipment

X capacitor CX1 used, 0.1μF

P

Measured voltage (V); time-constant (s) ................:

97.6V, 0.044s

⎯

2.1.1.8

Energy hazards – d.c. mains supply

N

a) Capacitor connected to the d.c. mains supply ..:

N

b) Internal battery connected to the d.c. mains
supply ....................................................................:

N

2.1.1.9

Audio amplifiers .....................................................:

2.1.2

Protection in service access areas

N

2.1.3

Protection in restricted access locations

N

2.2

SELV circuits

P

2.2.1

General requirements

P

2.2.2

Voltages under normal conditions (V) .................. :

(see appended tables 2.2)

P

2.2.3

Voltages under fault conditions (V) ...................... :

(see appended tables 2.2)

P

2.2.4

Connection of SELV circuits to other circuits ......:

Connect to SELV circuit only

P

TRF No. IEC60950_1B_M2

No such componet

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 9 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

2.3

TNV circuits

2.3.1

Limits

Result - Remark

Verdict
N

No TNV circuits

N

Type of TNV circuits .............................................. :

⎯

2.3.2

Separation from other circuits and from accessible
parts

N

2.3.2.1

General requirements

N

2.3.2.2

Protection by basic insulation

N

2.3.2.3

Protection by earthing

N

2.3.2.4

Protection by other constructions ......................... :

N

2.3.3

Separation from hazardous voltages

N

Insulation employed............................................... :

⎯

Connection of TNV circuits to other circuits

N

Insulation employed............................................... :

⎯

2.3.5

Test for operating voltages generated externally

N

2.4

Limited current circuits

P

2.4.1

General requirements

Considered.

P

2.4.2

Limit values

75.6mA

P

Frequency (Hz).......................................................:

108KHz

⎯

Measured current (mA) ..........................................:

4mA

⎯

Measured voltage (V) .............................................:

8V

⎯

Measured circuit capacitance (nF or µF)................:

CY1: 2200PF;
CY2, CY3: 1000PF

⎯

2.4.3

Connection of limited current circuits to other
circuits

Under normal operating
condition and in the event of a
single failure

P

2.5

Limited power sources

P

a) Inherently limited output

N

b) Impedance limited output

N

2.3.4

c) Regulating network limited output under normal
operating and single fault condition

(see appended table 2.5)

d) Overcurrent protective device limited output
Max. output voltage (V), max. output current (A),
max. apparent power (VA) .................................... :

P
N

See append tabel

⎯

Current rating of overcurrent protective device (A) .:

⎯

Use of integrated circuit (IC) current limiters

⎯

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 10 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.6

Provisions for earthing and bonding

P

2.6.1

Protective earthing

P

2.6.2

Functional earthing

N

2.6.3

Protective earthing and protective bonding
conductors

P

2.6.3.1

General

P

2.6.3.2

Size of protective earthing conductors
2

Rated current (A), cross-sectional area (mm ),
AWG ...................................................................... :
2.6.3.3

Verdict

Power cord set

P

2

⎯

0.5A, 0.75mm

Size of protective bonding conductors

P

Rated current (A), cross-sectional area (mm2),
AWG ...................................................................... :

⎯

Protective current rating (A), cross-sectional area
(mm2), AWG .......................................................... :

0.5A, 18AWG

⎯

2.6.3.4

Resistance of earthing conductors and their
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min) ..................................... :

0.067Ω

P

2.6.3.5

Colour of insulation................................................ :

The color combination green
and yellow is used

P

2.6.4

Terminals

P

2.6.4.1

General

P

2.6.4.2

Protective earthing and bonding terminals

Appliance coupler used

P

Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :

⎯

2.6.4.3

Separation of the protective earthing conductor
from protective bonding conductors

P

2.6.5

Integrity of protective earthing

P

2.6.5.1

Interconnection of equipment

N

2.6.5.2

Components in protective earthing conductors and
protective bonding conductors

P

2.6.5.3

Disconnection of protective earth

N

2.6.5.4

Parts that can be removed by an operator

2.6.5.5

Parts removed during servicing

N

2.6.5.6

Corrosion resistance

N

2.6.5.7

Screws for protective bonding

P

2.6.5.8

Reliance on telecommunication network or cable
distribution system

N

2.7

Overcurrent and earth fault protection in primary circuits

P

TRF No. IEC60950_1B_M2

AC plug and applice coupler

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 11 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.7.1

Basic requirements

Fuse F1 used

Verdict
P

Instructions when protection relies on building
installation

N

2.7.2

Faults not simulated in 5.3.7

N

2.7.3

Short-circuit backup protection

By building installation

P

2.7.4

Number and location of protective devices .......... :

One fuse

P

2.7.5

Protection by several devices

N

2.7.6

Warning to service personnel................................ :

N

2.8

Safety interlocks

N

2.8.1

General principles

2.8.2

Protection requirements

N

2.8.3

Inadvertent reactivation

N

2.8.4

Fail-safe operation

N

Protection against extreme hazard

N

2.8.5

Moving parts

N

2.8.6

Overriding

N

2.8.7

Switches, relays and their related circuits

N

2.8.7.1

Separation distances for contact gaps and their
related circuits (mm) ..............................................:

N

2.8.7.2

Overload test

N

2.8.7.3

Endurance test

N

2.8.7.4

Electric strength test

2.8.8

Mechanical actuators

N

2.9

Electrical insulation

P

2.9.1

Properties of insulating materials

P

2.9.2

Humidity conditioning

48 hrs

P

Relative humidity (%), temperature (°C) .............. :

30°C, 93%

⎯

2.9.3

Grade of insulation

Basic insulation

P

2.9.4

Separation from hazardous voltages
Method(s) used ..................................................... :

No safety interlocks

(see appended table 5.2)

N

N

P
Method 1

⎯

2.10

Clearances, creepage distances and distances through insulation

P

2.10.1

General

P

2.10.1.1

Frequency ..............................................................:

<30KHz

P

2.10.1.2

Pollution degrees ...................................................:

2

P

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 12 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.10.1.3

Reduced values for functional insualtion

P

2.10.1.4

Intervening unconnected conductive parts

P

2.10.1.5

Insulation with varying dimensions

N

2.10.1.6

Special separation requirements

N

2.10.1.7

Insulation in circuits generating starting pulses

N

2.10.2

Determination of working voltage

P

2.10.2.1

General

2.10.2.2

RMS working voltage

P

2.10.2.3

Peak working voltage

P

2.10.3

Clearances

N

2.10.3.1

General

P

2.10.3.2

Mains transient voltages

2500V

P

a) AC mains supply ...............................................:

100-240V

P

See appended table 2.10.2

Verdict

P

b) Earthed d.c. mains supplies ..............................:

N

c) Unearthed d.c. mains supplies ..........................:

N

d) Battery operation ...............................................:

N

2.10.3.3

Clearances in primary circuits

See appended table 2.10.3 &
2.10.4

2.10.3.4

Clearances in secondary circuits

N

2.10.3.5

Clearances in circuits having starting pulses

N

2.10.3.6

Transients from a.c. mains supply .........................:

N

2.10.3.7

Transients from d.c. mains supply .........................:

N

2.10.3.8

Transients from telecommunication networks and
cable distribution systems .....................................:

N

2.10.3.9

Measurement of transient voltage levels

N

a) Transients from a mains suplply

N

For an a.c. mains supply .......................................:

N

For a d.c. mains supply .........................................:

N

b) Transients from a telecommunication network :

N

2.10.4

Creepage distances

2.10.4.1

General

P

2.10.4.2

Material group and caomparative tracking index

P

CTI tests .................................................................:

See appended table 2.10.3 &
2.10.4

P

IIIb

P

⎯

2.10.4.3

Minimum creepage distances

2.10.5

Solid insulation

2.10.5.1

General

P

2.10.5.2

Distances through insulation

P

TRF No. IEC60950_1B_M2

P
See appended table 2.10.5

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 13 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

2.10.5.3

Insulating compound as solid insulation

N

2.10.5.4

Semiconductor devices

N

2.10.5.5.

Cemented joints

N

2.10.5.6

Thin sheet material – General

N

2.10.5.7

Separable thin sheet material

N

Number of layers (pcs) ...........................................:

⎯

2.10.5.8

Non-separable thin sheet material

N

2.10.5.9

Thin sheet material – standard test procedure

N

Electric strength test

⎯

Thin sheet material – alternative test procedure

N

Electric strength test

⎯

2.10.5.11

Insulation in wound components

P

2.10.5.12

Wire in wound components

P

Working voltage .....................................................:

N

a) Basic insulation not under stress ......................:

N

b) Basic, supplemetary, reinforced insulation .......:

N

2.10.5.10

2.10.5.13

Result - Remark

Verdict

c) Compliance with Annex U .................................:

Approved triple insulation wire
used in secondary

P

Two wires in contact inside wound component;
angle between 45° and 90° ...................................:

Separated by tape and tube

P

Wire with solvent-based enamel in wound
components

N

Electric strength test

⎯

Routine test

N

Additional insulation in wound components

N

Working voltage .....................................................:

N

- Basic insulation not under stress ........................:

N

- Supplemetary, reinforced insulation ....................:

N

2.10.6

Construction of printed boards

P

2.10.6.1

Uncoated printed boards

2.10.6.2

Coated printed boards

N

2.10.6.3

Insulation between conductors on the same inner
surface of a printed board

N

2.10.6.4

Insulation between conductors on different layers of
a printed board

N

Distance through insulation

N

Number of insulation layers (pcs)...........................:

N

2.10.5.14

TRF No. IEC60950_1B_M2

See appended table 2.10.3 &
2.10.4

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 14 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

2.10.7

Component external terminations

N

2.10.8

Tests on coated printed boards and coated
components

N

2.10.8.1

Sample preparation and preliminary inspection

N

2.10.8.2

Thermal conditioning

N

2.10.8.3

Electric strength test

N

2.10.8.4

Abrasion resistance test

N

2.10.9

Thermal cycling

N

2.10.10

Test for Pollution Degree 1 environment and
insulating compound

N

2.10.11

Tests for semiconductor devices and cemented
joints

N

2.10.12

Enclosed and sealed parts

N

3

WIRING, CONNECTIONS AND SUPPLY

P

3.1

General

P

3.1.1

Current rating and overcurrent protection

No hazards

P

3.1.2

Protection against mechanical damage

No hazards

P

3.1.3

Securing of internal wiring

No hazards

P

3.1.4

Insulation of conductors

Basic insulation for inside

P

3.1.5

Beads and ceramic insulators

No such parts

N

3.1.6

Screws for electrical contact pressure

No such screw

N

3.1.7

Insulating materials in electrical connections

3.1.8

Self-tapping and spaced thread screws

No such screw

N

3.1.9

Termination of conductors

Screw and soldering

P

N

10 N pull test

P

3.1.10

Sleeving on wiring

Heat-shrinkable tube fixed on
terminal

3.2

Connection to a mains supply

3.2.1

Means of connection ...........................................:

3.2.1.1

Connection to an a.c. mains supply

P

3.2.1.2

Connection to a d.c. mains supply

N

3.2.2

Multiple supply connections

N

3.2.3

Permanently connected equipment

P
Mains plug and appliance
coupler

Not such equipment

Appliance inlets

TRF No. IEC60950_1B_M2

P

N
⎯

Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
3.2.4

P

Appliance inlet was approved

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 15 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

3.2.5

Power supply cords

Power cord set was approved

3.2.5.1

AC power supply cords
2

Rated current (A), cross-sectional area (mm ),
AWG ..................................................................... :
DC power supply cords

3.2.6

Cord anchorages and strain relief

P
P

Type ...................................................................... :

3.2.5.2

Verdict

⎯

H03VV-F
3G0.75mm

2

⎯
N

Detached power cord used

N

Mass of equipment (kg), pull (N) ......................... :

⎯

Longitudinal displacement (mm) .......................... :

⎯

3.2.7

Protection against mechanical damage

N

3.2.8

Cord guards

N

Diameter or minor dimension D (mm); test mass (g)
............................................................................... :

⎯

Radius of curvature of cord (mm).......................... :

⎯

3.2.9

Supply wiring space

N

3.3

Wiring terminals for connection of external conductors

N

3.3.1

Wiring terminals

N

3.3.2

Connection of non-detachable power supply cords

N

3.3.3

Screw terminals

N

3.3.4

Conductor sizes to be connected

N

Rated current (A), cord/cable type, cross-sectional
area (mm2)............................................................. :

⎯

Wiring terminal sizes

N

Rated current (A), type, nominal thread diameter
(mm) ..................................................................... :

⎯

3.3.6

Wiring terminal design

N

3.3.7

Grouping of wiring terminals

N

3.3.8

Stranded wire

N

3.4

Disconnection from the mains supply

P

3.4.1

General requirement

P

3.4.2

Disconnect devices

3.4.3

Permanently connected equipment

N

3.4.4

Parts which remain energized

N

3.4.5

Switches in flexible cords

N

3.4.6

Number of poles - single-phase and d.c. equipment

P

3.4.7

Number of poles - three-phase equipment

N

3.3.5

TRF No. IEC60950_1B_M2

Appliance coupler used

AC plug and appliance
coupler

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 16 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

3.4.8

Switches as disconnect devices

3.4.9

Plugs as disconnect devices

3.4.10

Interconnected equipment

N

3.4.11

Multiple power sources

N

3.5

Interconnection of equipment

P

3.5.1

General requirements

P

3.5.2

Types of interconnection circuits .......................... :

3.5.3

ELV circuits as interconnection circuits

N

3.5.4

Data ports for additional equipment

P

4

PHYSICAL REQUIREMENTS

P

4.1

Stability

N

Angle of 10°

N

Test force (N) .........................................................:
4.2

Mechanical strength

4.2.1

General

Result - Remark

Verdict
N

Appliance coupler used also

SELV circuits to SELV circuits

< 7kg

N

P

N
P

Metal enclosure used

P

Rack-mounted equipment.

P

4.2.2

Steady force test, 10 N

N

4.2.3

Steady force test, 30 N

N

4.2.4

Steady force test, 250 N

P

4.2.5

Impact test

P

Fall test

500g, 1.3M

P

Swing test

500g, 1.3M

P

4.2.6

Drop test; height (mm) ...........................................:

N

4.2.7

Stress relief test

Metal enclosure used

N

4.2.8

Cathode ray tubes

No CRT.

N

Picture tube separately certified ............................:

N

4.2.9

High pressure lamps

No high pressure lamps.

N

4.2.10

Wall or ceiling mounted equipment; force (N) .......:

Not such equipments

N

4.3

Design and construction

4.3.1

Edges and corners

Edges and corners are
rounded or smoothed.

P

4.3.2

Handles and manual controls; force (N)............. :

No handles or controls
provided

N

4.3.3

Adjustable controls

No adjustable controls.

N

TRF No. IEC60950_1B_M2

P

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 17 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

4.3.4

Securing of parts

P

4.3.5

Connection by plugs and sockets

P

4.3.6

Direct plug-in equipment

N

Torque ..................................................................:

⎯

Compliance with the relevant mains plug standard
...............................................................................:

N

4.3.7

Heating elements in earthed equipment

No heating elements.

N

4.3.8

Batteries

No battery used

N

- Overcharging of a rechargeable battery

N

- Unintentional charging of a non-rechargeable
battery

N

- Reverse charging of a rechargeable battery

N

- Excessive discharging rate for any battery

N

4.3.9

Oil and grease

No oil or grease.

N

4.3.10

Dust, powders, liquids and gases

Equipment in intended use
not considered to be exposed
to these.

N

4.3.11

Containers for liquids or gases

No container for liquid or gas.

N

4.3.12

Flammable liquids .................................................:

No flammable liquid.

N

Quantity of liquid (l) ...............................................:

N

Flash point (°C) .....................................................:

N

4.3.13

Radiation

P

4.3.13.1

General

N

4.3.13.2

Ionizing radiation

N

Measured radiation (pA/kg) ..................................:

⎯

Measured high-voltage (kV) .................................:

⎯

Measured focus voltage (kV) ................................:

⎯

CRT markings .......................................................:

⎯

Effect of ultraviolet (UV) radiation on materials

N

Part, property, retention after test, flammability
classification .........................................................:

N

4.3.13.4

Human exposure to ultraviolet (UV) radiation ......:

N

4.3.13.5

Lasers (including laser diodes) and LEDs

P

4.3.13.5.1

Lasers (including laser laser diodes)

N

Laser class ...........................................................:

⎯

4.3.13.3

4.3.13.5.2

Light emitting diodes (LEDs)

4.3.13.6

Other types ...........................................................:

N

4.4

Protection against hazardous moving parts

N

TRF No. IEC60950_1B_M2

LED used for indication only

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 18 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

4.4.1

General

No moving parts

N

4.4.2

Protection in operator access areas .................... :
Household and home/office document/media
shredders

N
(see Annex EE)

N

4.4.3

Protection in restricted access locations ............. :

N

4.4.4

Protection in service access areas

N

4.4.5

Protection against moving fan blades

N

4.4.5.1

General

N

Not considered to cause pain or injury. a)………….:

N

Is considered to cause pain, not injury. b) …………:

N

Considered to cause injury.

N

4.4.5.2

c) …………:

Protection for users

N

Use of symbol or warning ……………………………:

N

Protection for service persons

N

Use of symbol or warning ……………………………:

N

4.5

Thermal requirements

P

4.5.1

General

P

4.5.2

Temperature tests

P

Normal load condition per Annex L ..................... :

⎯

4.4.5.3

4.5.3

Temperature limits for materials

(see appended table 4.5)

P

4.5.4

Touch temperature limits

(see appended table 4.5)

P

4.5.5

Resistance to abnormal heat ............................... :

(see appended table 4.5.5)

P

4.6

Openings in enclosures

4.6.1

Top and side openings

side openings

P

Dimensions (mm) ................................................ :

Diameter: 2.85mm

⎯

Bottoms of fire enclosures

Metal enclosure

P

4.6.2

P

⎯

Construction of the bottomm, dimensions (mm) . :
4.6.3

Doors or covers in fire enclosures

No doors or covers

N

4.6.4

Openings in transportable equipment

Not such equipment.

N

4.6.4.1

Constructional design measures

N

Dimensions (mm) ................................................ :

⎯

4.6.4.2

Evaluation measures for larger openings

N

4.6.4.3

Use of metallized parts

N

4.6.5

Adhesives for constructional purposes

No barrier of screen fixed by
glue inside subwoofer

Conditioning temperature (°C), time (weeks) ....... :

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N
⎯

Page 19 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

4.7

Resistance to fire

4.7.1

Reducing the risk of ignition and spread of flame

Metal enclosure

P

Method 1, selection and application of components
wiring and materials

See cl 4.7.2.2

P

P

Method 2, application of all of simulated fault
condition tests

N

4.7.2

Conditions for a fire enclosure

N

4.7.2.1

Parts requiring a fire enclosure

N

4.7.2.2

Parts not requiring a fire enclosure

P

4.7.3

Materials

P

4.7.3.1

General

4.7.3.2

Materials for fire enclosures

4.7.3.3

Materials for components and other parts outside
fire enclosures

4.7.3.4

Materials for components and other parts inside fire
enclosures

4.7.3.5

Materials for air filter assemblies

No air filter assemblies

N

4.7.3.6

Materials used in high-voltage components

No high-voltage component

N

5

ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS

P

5.1

Touch current and protective conductor current

P

5.1.1

General

5.1.2

Configuration of equipment under test (EUT)

P

5.1.2.1

Single connection to an a.c. mains supply

P

5.1.2.2

Redundant multiple connections to an a.c. mains
supply

N

5.1.2.3

Simultaneous multiple connections to an a.c. mains
supply

N

5.1.3

Test circuit

Figure 5A

P

5.1.4

Application of measuring instrument

Annex D

P

5.1.5

Test procedure

Between Mains and metal
enclosure & terminal

P

5.1.6

Test measurements

See appended table 1.5.1.

P
N

Not require fire enclosure

N
N

Class I equipment

P

P

Supply voltage (V) ................................................:

264V, 60Hz

⎯

Measured touch current (mA) ...............................:

0.488

⎯

Max. allowed touch current (mA) ..........................:

3.5

⎯

Measured protective conductor current (mA) .......:

--

⎯

Max. allowed protective conductor current (mA)...:

--

⎯

5.1.7

Equipment with touch current exceeding 3,5 mA

N

5.1.7.1

General .................................................................:

N

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 20 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

5.1.7.2

Simultaneous multiple connections to the supply

5.1.8

Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks

5.1.8.1

Limitation of the touch current to a
telecommunication network or to a cable distribution
system

N

Supply voltage (V) ................................................:

⎯

Measured touch current (mA) ...............................:

⎯

Max. allowed touch current (mA) ..........................:

⎯

Summation of touch currents from
telecommunication networks

N

a) EUT with earthed telecommunication ports .....:

N

b) EUT whose telecommunication ports have no
reference to protective earth

N

5.2

Electric strength

P

5.2.1

General

(see appended table 5.2)

P

5.2.2

Test procedure

(see appended table 5.2)

P

5.3

Abnormal operating and fault conditions

P

5.3.1

Protection against overload and abnormal operation (see appended table 5.3)

P

5.3.2

Motors

N

5.3.3

Transformers

(see appended Annex C)

P

5.3.4

Functional insulation..............................................:

Result see appened table 5.3

P

5.3.5

Electromechanical components

No such component

N

5.3.6

Audio amplifiers in ITE ..........................................:

No such component

N

5.3.7

Simulation of faults

(see appended table 5.3)

P

5.3.8

Unattended equipment

No such equipment

N

5.3.9

Compliance criteria for abnormal operating and fault
conditions

5.3.9.1

During the tests

No fire, no molten metal, no
enclosure deformation and no
temperature exceeding those
in table 5D

P

5.3.9.2

After the tests

No any hazards

P

6

CONNECTION TO TELECOMMUNICATION NETWORKS

N

6.1

Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment

N

5.1.8.2

TRF No. IEC60950_1B_M2

Result - Remark

Verdict
N

No TNV circuit connection
provided

N

P

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 21 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

6.1.1

Protection from hazardous voltages

N

6.1.2

Separation of the telecommunication network from earth

N

6.1.2.1

Requirements

N

Supply voltage (V) ................................................:

⎯

Current in the test circuit (mA) ...........................:

⎯

6.1.2.2

Exclusions ............................................................:

N

6.2

Protection of equipment users from overvoltages on telecommunication networks

N

6.2.1

Separation requirements

N

6.2.2

Electric strength test procedure

N

6.2.2.1

Impulse test

N

6.2.2.2

Steady-state test

N

6.2.2.3

Compliance criteria

N

6.3

Protection of the telecommunication wiring system from overheating

N

Max. output current (A) ........................................:

⎯

No telecommunication wiring
system

Verdict

Current limiting method ........................................:

⎯

7

CONNECTION TO CABLE DISTRIBUTION SYSTEMS

N

7.1

General

N

7.2

Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment

N

7.3

Protection of equipment users from overvoltages on
the cable distribution system

N

7.4

Insulation between primary circuits and cable
distribution systems

N

7.4.1

General

N

7.4.2

Voltage surge test

N

7.4.3

Impulse test

N

A

ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE

N

A.1

Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)

N

A.1.1

Samples ................................................................ :

⎯

Wall thickness (mm).............................................. :

⎯

TRF No. IEC60950_1B_M2

No cable distribution system

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 22 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

A.1.2

Conditioning of samples; temperature (°C) ......... :

N

A.1.3

Mounting of samples ............................................ :

N

A.1.4

Test flame (see IEC 60695-11-3)

N

Flame A, B, C or D ............................................... :

⎯

A.1.5

Test procedure

N

A.1.6

Compliance criteria

N

Sample 1 burning time (s)..................................... :

⎯

Sample 2 burning time (s)..................................... :

⎯

Sample 3 burning time (s)..................................... :

⎯

A.2

Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)

N

A.2.1

Samples, material ................................................. :

⎯

Wall thickness (mm).............................................. :

⎯

A.2.2

Conditioning of samples; temperature (°C) ......... :

N

A.2.3

Mounting of samples ............................................ :

N

A.2.4

Test flame (see IEC 60695-11-4)

N

Flame A, B or C .................................................... :

⎯

A.2.5

Test procedure

N

A.2.6

Compliance criteria

N

Sample 1 burning time (s)..................................... :

⎯

Sample 2 burning time (s)..................................... :

⎯

Sample 3 burning time (s)..................................... :

⎯

Alternative test acc. to IEC 60695-11-5, cl. 5 and 9

N

Sample 1 burning time (s)..................................... :

⎯

Sample 2 burning time (s)..................................... :

⎯

Sample 3 burning time (s)..................................... :

⎯

A.3

Hot flaming oil test (see 4.6.2)

N

A.3.1

Mounting of samples

N

A.3.2

Test procedure

N

A.3.3

Compliance criterion

N

B

ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)

N

B.1

General requirements

N

A.2.7

Result - Remark

(see appended table 1.5.1)

Verdict

Position ................................................................ :

⎯

Manufacturer ........................................................ :

⎯

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 23 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Type ..................................................................... :

⎯

Rated values ....................................................... :

⎯

B.2

Test conditions

N

B.3

Maximum temperatures

N

B.4

Running overload test

N

B.5

Locked-rotor overload test

N

Test duration (days) ............................................. :

⎯

Electric strength test: test voltage (V) .................. :

⎯

B.6

Running overload test for d.c. motors in secondary
circuits

P

B.6.1

General

N

B.6.2

Test procedure

N

B.6.3

Alternative test procedure

N

B.6.4

Electric strength test; test voltage (V) .................. :

N

B.7

Locked-rotor overload test for d.c. motors in
secondary circuits

B.7.1

General

N

B.7.2

Test procedure

N

B.7.3

Alternative test procedure

N

B.7.4

Electric strength test; test voltage (V) ................. :

N

B.8

Test for motors with capacitors

N

B.9

Test for three-phase motors

N

B.10

Test for series motors

N

Operating voltage (V) ........................................... :

⎯

ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)

P

C

(see appended table 5.3)

P

Position ................................................................ :

FR-SPS5V2A000

⎯

Manufacturer ........................................................ :

(see appended tabel 1.5.1)

⎯

Type ..................................................................... :

(see appended tabel 1.5.1)

⎯

Rated values ....................................................... :

(see appended tabel 1.5.1)

⎯

Method of protection .............................................:

Inherent

⎯

C.1

Overload test

(see appended tabel 5.3)

P

C.2

Insulation
Protection from displacement of windings ............:

TRF No. IEC60950_1B_M2

P
Approved triple insutlation
wire used in secdary

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 24 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

D

ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)

P

D.1

Measuring instrument

P

D.2

Alternative measuring instrument

N

E

ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)

N

F

ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)

P

G

ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES

N

G.1

Clearances

N

G.1.1

General

N

G.1.2

Summary of the procedure for determining
minimum clearances

N

G.2

Determination of mains transient voltage (V)

N

G.2.1

AC mains supply .................................................. :

N

G.2.2

Earthed d.c. mains supplies ................................. :

N

G.2.3

Unearthed d.c. mains supplies ............................ :

N

G.2.4

Battery operation .................................................. :

N

G.3

Determination of telecommunication network
transient voltage (V) ............................................. :

N

G.4

Determination of required withstand voltage (V)

N

G.4.1

Mains transients and internal repetitive peaks .... :

N

G.4.2

Transients from telecommunication networks ..... :

N

G.4.3

Combination of transients

N

G.4.4

Transients from cable distribution systems

N

G.5

Measurement of transient voltages (V)

N

a) Transients from a mains supply

N

For an a.c. mains supply

N

For a d.c. mains supply

N

b) Transients from a telecommunication network

N

G.6

Determination of minimum clearances ................ :

N

H

ANNEX H, IONIZING RADIATION (see 4.3.13)

N

J

ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)

N

TRF No. IEC60950_1B_M2

Result - Remark

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

Page 25 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Metal(s) used ....................................................... :

⎯

K

ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)

N

K.1

Making and breaking capacity

N

K.2

Thermostat reliability; operating voltage (V) ........ :

N

K.3

Thermostat endurance test; operating voltage (V)
.............................................................................. :

N

K.4

Temperature limiter endurance; operating voltage
(V) ........................................................................ :

N

K.5

Thermal cut-out reliability

N

K.6

Stability of operation

N

L

ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)

P

L.1

Typewriters

N

L.2

Adding machines and cash registers

N

L.3

Erasers

N

L.4

Pencil sharpeners

N

L.5

Duplicators and copy machines

N

L.6

Motor-operated files

N

L.7

Other business equipment

M

ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)

N

M.1

Introduction

N

M.2

Method A

N

M.3

Method B

N

M.3.1

Ringing signal

N

M.3.1.1

Frequency (Hz) .................................................... :

⎯

M.3.1.2

Voltage (V) ........................................................... :

⎯

M.3.1.3

Cadence; time (s), voltage (V) ............................. :

⎯

M.3.1.4

Single fault current (mA) ...................................... :

⎯

M.3.2

Tripping device and monitoring voltage ............... :

N

M.3.2.1

Conditions for use of a tripping device or a
monitoring voltage

N

M.3.2.2

Tripping device

N

M.3.2.3

Monitoring voltage (V) .......................................... :

N

TRF No. IEC60950_1B_M2

See condition in appended
table 1.6.2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 26 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

N

ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)

N

N.1

ITU-T impulse test generators

N

N.2

IEC 60065 impulse test generator

N

P

ANNEX P, NORMATIVE REFERENCES

⎯

Q

ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)

P

- Preferred climatic categories ............................. :

P

(see appended tabel 1.5.1)
Varistor was apploved

Verdict

- Maximum continuous voltage ............................ :

P

- Combination pulse current ................................. :

P

Body of the VDR
Test according to IEC60695-11-5 ........................ :

P

Body of the VDR.
Flammability class of material ( min V-1) ............. :

P

R

ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES

N

R.1

Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)

N

R.2

Reduced clearances (see 2.10.3)

N

S

ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)

N

S.1

Test equipment

N

S.2

Test procedure

N

S.3

Examples of waveforms during impulse testing

N

T

ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)

N
⎯

U

ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
Approved triple insulation
wire used in secondary

P
⎯

V

ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)

N

V.1

Introduction

N

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 27 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

V.2

TN power distribution systems

N

W

ANNEX W, SUMMATION OF TOUCH CURRENTS

N

W.1

Touch current from electronic circuits

N

W.1.1

Floating circuits

N

W.1.2

Earthed circuits

N

W.2

Interconnection of several equipments

N

W.2.1

Isolation

N

W.2.2

Common return, isolated from earth

N

W.2.3

Common return, connected to protective earth

N

X

ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS
(see clause C.1)

N

X.1

Determination of maximum input current

N

X.2

Overload test procedure

N

Y

ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)

N

Y.1

Test apparatus ......................................................:

N

Y.2

Mounting of test samples .....................................:

N

Y.3

Carbon-arc light-exposure apparatus ...................:

N

Y.4

Xenon-arc light exposure apparatus ....................:

N

Z

ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)

P

AA

ANNEX AA, MANDREL TEST (see 2.10.5.8)

N

BB

ANNEX BB, CHANGES IN THE SECOND EDITION

⎯

CC

ANNEX CC, Evaluation of integrated circuit (IC) current limiters

N

CC.1

General

N

CC.2

Test program 1 ..................................................... :

N

CC.3

Test program 2 ..................................................... :

N

CC.4

Test program 3 ..................................................... :

N

CC.5

Compliance .......................................................... :

N

DD

ANNEX DD, Requirements for the mounting means of rack-mounted
equipment

N

TRF No. IEC60950_1B_M2

Result - Remark

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

Page 28 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

DD.1

General

N

DD.2

Mechanical strength test, variable N………………..:

N

DD.3

Mechanical strength test, 250N, including end
stops……………………………………………………:

N

DD.4

Compliance……………………………………………:

N

EE

ANNEX EE, Household and home/office document/media shredders

N

EE.1

General

N

EE.2

Markings and instructions

N

Use of markings or symbols…………………………:

N

Information of user instructions, maintenance and/or
servicing instructions…………………………:

N

EE.3

Inadvertent reactivation test…………………………:

N

EE.4

Disconnection of power to hazardous moving parts:

N

Use of markings or symbols…………………………:

N

Protection against hazardous moving parts

N

Test with test finger (Figure 2A) ……………………:

N

Test with wedge probe (Figure EE1 and EE2) ……:

N

EE.5

TRF No. IEC60950_1B_M2

Result - Remark

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

Page 29 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

1.5.1

TABLE: List of critical components

Object/part
No.

Manufacturer/
trademark

AC plug

AC connector

Type/model

Verdict

P
Technical data

Standard
(Edition /
year)

Mark(s) of
conformity1)

16A, 250V~

VDE 0620-1

VDE
40026370

Shenzhen Yuxin Wire YX-201
& Cable Co., Ltd.

16A, 250V~

VDE 0620-1

VDE
40001445

Shenzhen Baohing
Electric Wire
& Cable Manufacture
Co., Ltd.

H03VV-F

3G0.75mm2

HD 21.5
S3+A1+A2

VDE 103727

Shenzhen Yuxin Wire H03VV-F
& Cable Co., Ltd.

3G0.75mm2

HD 21.5
S3+A1+A2

VDE
40012386

Shenzhen HongPu
Electron Co., Ltd.

10A, 250V~

EN 60320-1

VDE
40025516

10A, 250V~

EN 60320-1

VDE
40035945

Shenzhen HongPu
Electron Co., Ltd.

Power cord

Result - Remark

XTH-005

XTH-021

Shenzhen Yuxin Wire YX-210
& Cable Co., Ltd.
Appliance Inlet Rich Bay Co., Ltd.

R-30190

10A, 250Vac

EN 60320-1

VDE
40030224

PCB

Various

Various

V-1 or better,
Min. 105°C

UL 94,
UL 746

UL

Heatshrinkable
tube

Shenzhen Wolida
Trading Co., Ltd.

RSFR-H

600V, 125°C

UL 224

UL E329530

Earth wire &
Output wire

Zhongshan Dongfeng 1015
Zhoushishenlong
Electronic Wire Co.,
Ltd.

105°C, 600V,
18AWG, VW-1

UL 758

UL E257280

Fuse F1

Dongguan Better
Electronic
Technology Co., Ltd.

332

T1.0AL250VAC

EN 60127-1,
EN 60127-3

TÜV
Rheinland
Cert. No.: J
50158950

Varistor VZ1

Guangxi New Future
Information
Industry Co., Ltd.

10D471K

470VAC, 85°C

IEC 61051-1,
IEC 61051-2,
IEC 61051-22

VDE
40030322

X-Capacitor
CX1

Tenta Electric
Industrial Co Ltd

MEX

Min.275Vac Max.
0.1μF, 100°C

IEC 60384-14 VDE 119119

Thermal
resistor NTC1

Guangdong South
Hongming Electronic
Science &
Technology Co., Ltd.

5D-7

240V, Imax: 2A, 5Ω at UL 1434
25°C

UL E365062

Hongzhi Enterprises
Ltd.

5D-7

240V, Imax: 2A, 5Ω at UL 1434
25°C

UL E319959

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 30 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Object/part
No.

Manufacturer/
trademark

Result - Remark

Type/model

Technical data

Standard
(Edition /
year)

Verdict

Mark(s) of
conformity1)

Optocoupler
IC3

Bright Led Electronics BPC-817
Corp.

Dti≥0.4mm,
Cr=8.0mm,
Cl=7.6mm, 100°C

IEC 60747-52

Y- Capacitor
CY1

TDK-EPC
Corporation

CD

2200pF, 250Vac, Y1,
125°C

IEC 60384-14 VDE
40029780

TDK-EPC
Corporation

CS

2200Pf, 250Vac, Y1,
125°C

IEC 60384-14 VDE
40029781

TDK-EPC
Corporation

CD

1000pF, 250Vac, Y1,
125°C

IEC 60384-14 VDE
40029780

TDK-EPC
Corporation

CS

1000pF, 250Vac, Y1,
125°C

IEC 60384-14 VDE
40029781

Inductors LF1

Yishan Electronics
Co., Ltd.

YSL1105

Min. 25mH

EN 60950-1

Tested
within
appliance

Bobbin of LF1

Chang Chun Plastics
Co., Ltd.

T375J

V-0, 150°C

UL 746

UL E59481

Winding of
LF1

Shenzhen Chengwei
Industry Co., Ltd.

2UEW

130°C

UL 1446

UL E227475

Transformer
T1

Yishan Electronics
Co., Ltd.

FR-SPS5V2
A000

EN 60950-1
Primary:
N1: Φ0.25mm*1*95TS
N3: Φ0.25mm*1*25TS
N4: Φ0.12mm*1*12TS
Secondary:
N2: Φ0.60mm*1*7TS

Tested
within
appliance

Bobbin of T1

Chang Chun Plastics
Co., Ltd.

T375J

V-0, 150°C

UL 746

UL E59481

Winding of T1

Shenzhen Chengwei
Industry Co., Ltd.

2UEW

130°C

UL 1446

UL E227475

Triple
Furukawa Electric
insulation wire Co., Ltd.
of T1

TEX-E

130°C

EN 60950-1
Annex U

VDE 006735

Insulation tube Changyuan
of T1
Electronics Group
Co., Ltd.

CB-TT-T

300V, 200°C

UL 224

UL E180908

Insulation tape Dongguan Shin
of T1
Yahua Electronic
Material Co., Ltd.

CT* (c)(g),
PZ* (b)

130°C

UL 510

UL E178516

Y- Capacitor
CY2, CY3

Supplementary information:/

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

VDE
40007240

Page 31 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

1.6.2

Result - Remark

Verdict

P

TABLE: Electrical data (in normal conditions)

Cond.

U (V)

Hz

I (A)

Irated (A)

P (W)

Fuse #

Ifuse (A)

Condition/status

01

90.0

50

0.115

--

5.6

F1

0.115

Normal operation

02

100.0

50

0.105

0.5

5.5

F1

0.105

03

240.0

50

0.055

0.5

4.9

F1

0.055

04

264.0

50

0.047

--

5.0

F1

0.047

05

90.0

60

0.117

--

5.6

F1

0.117

06

100.0

60

0.107

0.5

5.5

F1

0.107

07

240.0

60

0.053

0.5

4.9

F1

0.053

08

264.0

60

0.050

--

5.0

F1

0.050

Supplementary information: -2.1.1.5 c)
1)

P

TABLE: max. V, A, VA test

Voltage (rated)
(V)

Current (rated)
(A)

Voltage (max.)
(V)

Current (max.)
(A)

VA (max.)
(VA)

--

--

5.95

4.4

12.64

Supplementary information: Output of power supply PCB.

2.1.1.5 c)
2)

N

TABLE: stored energy

Capacitance C (µF)

Voltage U (V)

Energy E (J)

--

--

--

supplementary information:

2.2

TABLE: evaluation of voltage limiting components in SELV circuits

Component (measured between)

Output of power supply PCB
Fault test performed on voltage limiting components
S-C diode D7

max. voltage (V)
(normal operation)
V peak

V d.c.

--

5.95

Voltage Limiting Components

--

Voltage measured (V) in SELV circuits
(V peak or V d.c.)
Unit shut down, no output U=0

Remark: Output of power supply PCB

TRF No. IEC60950_1B_M2

P

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 32 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.4.2

TABLE: limited current circuit measurement

Location

Verdict

P

Voltage
(V)

Current
(mA)

Freq.
(Hz)

Limit
(mA)

Comments

8

4

108K

75.6

CY1: 2200pF

Between Y capacitor CY1
Remark:
2.5

P

TABLE: limited power sources

Circuit output tested: Output of power supply PCB
Measured Uoc (V) with all load circuits
disconnected:

5.95V
Isc (A)

VA

Meas.

Limit

Meas.

Limit

4.4

8.0

12.64

100

--

8.0

--

100

Normal condition
S-C diode D7

supplementary information: Unit shut down after S-C diode D7

2.10.2

P

Table: working voltage measurement

Location

RMS voltage (V)

Peak voltage (V) Comments

Transformer T1 pin 6- pin 1

240

404

--

Transformer T1 pin 6- pin 3

240

408

--

Transformer T1 pin 6- pin 4

240

404

--

Transformer T1 pin 6- pin 5

240

388

--

Transformer T1 pin 9- pin 1

240

380

--

Transformer T1 pin 9- pin 3

240

416

Max. RMS & Peak of T1

Transformer T1 pin 9- pin 4

240

376

--

Transformer T1 pin 9- pin 5

240

416

--

Optocoupler IC3 pin 1- pin 3

240

380

--

Optocoupler IC3 pin 1- pin 4

240

376

--

Optocoupler IC3 pin 2- pin 3

240

406

Max. RMS & Peak of

Optocoupler IC3 pin 2- pin 4

240

376

--

Y capacitor CY1 pin 1- pin 2

240

376

Max. RMS & Peak of YC200

supplementary information:

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 33 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

P

2.10.3 and TABLE: Clearance and creepage distance measurements
2.10.4
Clearance (cl) and creepage
distance (cr) at/of/between:

U peak
(V)

U r.m.s.
(V)

Required cl
(mm)

cl
(mm)

Required
cr (mm)

cr
(mm)

L and N

339

240

1.5

3.9

2.5

4.9

Two pins of F1

339

240

2.0

2.6

2.5

2.6

Live part and earth

339

240

2.0

3.0

2.5

3.0

Two pins of Capacitor CY1

376

240

4.0

5.5

5.0

5.7

Two pins of Capacitor CY2

339

240

2.0

3.0

2.5

3.0

Two pins of Capacitor CY3

339

240

2.0

3.0

2.5

3.0

Optocoupler IC3 (Pri.-Sec.)

406

240

4.0

5.5

5.0

5.5

Transformer T1 (Pri.-Sec.) on
PCB

416

240

4.0

5.5

5.0

5.5

Transformer T1 (Pri.-Sec.)

416

240

4.0

6.4

5.0

6.4

T1 Pri. winding and Sec. C5

339

240

4.0

7.8

5.0

>10

Live part and metal enclosure

339

240

2.0

3.0

2.5

3.0

Supplementary information: -2.10.5

P

TABLE: Distance through insulation measurements

Distance through insulation (DTI) at/of:

U peak
(V)

U rms
(V)

Test
voltage (V)

Required
DTI (mm)

DTI
(mm)

Transformer bobbin

416

240

3000

0.4

0.5

Optocoupler IC3

406

240

3000

0.4

≥0.4

Supplementary information: --

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 34 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

4.3.8

TABLE: Batteries

Result - Remark

Verdict
N

The tests of 4.3.8 are applicable only when appropriate battery
data is not available

No battery

N

Is it possible to install the battery in a reverse polarity position?
Non-rechargeable batteries
Discharging
Meas.
current

Manuf.
Specs.

Max.
current
during
normal
condition

--

--

Max.
current
during
fault
condition

--

--

Unintentional
charging

N
Rechargeable batteries

Charging
Meas.
current

Discharging

Manuf.
Specs.

Meas.
current

Manuf.
Specs.

Reversed
charging
Manuf.
Specs.

--

Meas.
current
--

--

--

--

--

Test results:

--

Verdict

- Chemical leaks

--

N

- Explosion of the battery

--

N

- Emission of flame or expulsion of molten metal

--

N

- Electric strength tests of equipment after completion of tests

--

N

Remark: --

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 35 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

4.3.8

TABLE: Batteries

Result - Remark

N

Battery category .......................................... :

--

Manufacturer ............................................... :

--

Type / model................................................ :

--

Voltage ........................................................ :

--

Capacity ...................................................... :

--

Tested and Certified by (incl. Ref. No.) ....... :

--

Circuit protection diagram:

MARKINGS AND INSTRUCTIONS (1.7.12, 1.7.15)
Location of replaceable battery

--

Language(s) …………………………………….:

--

Close to the battery …………………………….:

--

In the servicing instructions ……………………:

--

In the operating instructions …………………..:

--

TRF No. IEC60950_1B_M2

Verdict

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 36 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

4.5.1

TABLE: maximum temperatures

Verdict

P

Supply voltage (V) ..........

90.0

264.0

⎯

Ambient Tmin (°C) ............

24.4

24.0

⎯

Ambient Tmax (°C) ............

26.0

25.1

⎯

Maximum measured temperature T
of part/at:

T (°C)

Allowed Tmax (°C)

No. 05

No. 04

Inlet surface

33.8

30.8

95+24-50=69

X-Capacitor CX1

46.0

37.9

100+24-50=74

Inductors LF1 winding

49.4

39.4

110+24-50=84

PCB near D3

54.5

42.8

130+24-50=104

Capacitor C1

42.9

38.0

105+24-50=79

PCB near IC1

81.6

55.5

130+24-50=104

Optocoupler IC3

65.1

55.5

100+24-50=74

Transformer T1 winding

64.3

57.1

110+24-50=84

Y- Capacitor CY1

50.0

45.5

125+24-50=99

PCB near D7

56.4

53.4

130+24-50=104

Capacitor C5

55.8

54.6

105+24-50=79

Internal wire of Sec.

33.8

35.3

80+24-50=54

Capacitor CE2

39.1

40.9

105+24-50=79

PCB near U1

48.2

50.3

130+24-50=104

Component T1

34.7

36.8

Reference

PCB near UD1

35.2

57.0

130+24-50=104

Metal enclosure

31.1

32.6

70+24-50=44

Power cord

26.1

28.1

75+24-50=49

Temperature T of winding:
--

t1 (°C)

R1 (Ω)

t2 (°C)

R2 (Ω)

Allowed
Tmax (°C)

Insulation class

--

--

--

--

--

Supplementary information: * The winding permitted temperature rise would be reduced 10K while the
temperature rise measured for thermal-coupler method.
Allowed Tmax=Tmax+Tamb-Tma, Tamb=24°C, Tma=50°C.
The max operated temperature is 50°C which is specified by manufacturer

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 37 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

4.5.5

TABLE: Ball pressure test of thermoplastic parts

P

Allowed impression diameter (mm) .....................: ≤ 2 mm

⎯

Part

Verdict

Test temperature Impression diameter
(mm)
(°C)

Bobbin of LF1

125

1.07

Bobbin of T1

125

1.19

Supplementary information: -4.7

P

TABLE: Resistance to fire

Part

Manufacturer of
material

Type of material

Bobbin of LF1

Chang Chun Plastics
Co., Ltd.

T375J

3.0

V-0

UL E59481

Bobbin of T1

Chang Chun Plastics
Co., Ltd.

T375J

0.9

V-0

UL E59481

Various

Various

1.6

V-1

UL

Material of supply
PCB

Thickness Flammability
(mm)
class

Evidence

Supplementary information: -5.1

P

TABLE: touch current measurement

Measured between:
L/N and metal enclosure

Measured
(mA)

Limit
(mA)

0.488

3.5

Comments/conditions
--

supplementary information: Input voltage: 264V, 60Hz

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 38 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

5.2

Result - Remark

Verdict

P

TABLE: Electric strength tests, impulse tests and voltage surge tests

Test voltage applied between:

Voltage shape
(AC, DC,
impulse, surge)

Test
voltage
(V)

Breakdown
Yes / No

Between L-N and metal enclosure & terminal

AC

1500

No

Transformer primary and secondary

AC

3000

No

1 layer insulation of transformer

AC

3000

No

Between L and N without fuse F1

AC

1500

No

Supplementary information: -5.3

P

TABLE: Fault condition tests
Ambient temperature (°C) ...................................:

23.9-25.4

⎯

Power source for EUT: Manufacturer, model/type,
output rating .........................................................:

--

⎯

Component
No.

Fault

Supply
voltage (V)

Test
time

Fuse
#

Fuse
current (A)

Observation

--

Blocked
ventilation

264.0V

70mins

F1

0.047

∗ No hazard occurred and no
high temperature occurred.
∗ The max. temperature of LF1 is
39.6°C
The max. temperature of T1 is
57.4°C.

Capacitor C5

S-C

264.0V

30mins

F1

0.045↔
0.035

∗ No hazard occurred and no
high temperature occurred.
∗ Unit shut down.

Diode D7

S-C

264.0V

30mins

F1

0.029

∗ No hazard occurred and no
high temperature occurred.
∗ Unit shut down.

Optocoupler
IC3 Sec.

S-C

264.0V

30mins

F1

0.047

∗ No hazard occurred and no
high temperature occurred.
∗ Unit work as normal

Optocoupler
IC3 Pri.

S-C

264.0V

30mins

F1

0.011

∗ No hazard occurred and no
high temperature occurred.
∗ Unit shut down.

Capacitor C1

S-C

264.0V

1s

F1

0

∗ No hazard occurred and no
high temperature occurred.
∗ Fuse F1 opened immediately.

Diode D3

S-C

264.0V

1s

F1

0

∗ No hazard occurred and no
high temperature occurred.
∗ Fuse F1 opened immediately.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 39 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Component
No.

Fault

Supply
voltage (V)

Test
time

Fuse
#

Fuse
Observation
current (A)

T1 output

O-L

90V

150
mins

F1

0.264

∗ No hazard occurred and no
high temperature occurred.
The max. temperature of LF1 is
62.3°C.
The max. temperature of T1 is
96.0°C.
∗ The max. over-load current is
2.2A, over 2.2A, the unit shut
down.

T1 output

O-L

264.0V

150
mins

F1

0.184

∗ No hazard occurred and no
high temperature occurred.
The max. temperature of LF1 is
60.9°C.
The max. temperature of T1 is
119.9°C.
∗ The max. over-load current is
3.0A, over 3.0A, the unit shut
down.

Supplementary information: S-C is abbreviation of shorted- circuit. O-L is abbreviation of over-load.
The limit of LF1 and T1 winding: 165+23.9-50=138.9°C

C.2

TABLE: transformers

Loc.

Tested insulation

P
Working
voltage
peak / V

Working
voltage
rms / V

Required
electric
strength

Required
clearance /
mm

Required
distance
thr. insul.

(2.10.3)

Required
creepage
distance /
mm
(2.10.4)

(2.10.2)

(2.10.2)

(5.2)

3000Vac

4.0

5.0

*

(2.10.5)

T1 Pri. to
Sec.

Reinforced insulation

Loc.

Tested insulation

Test
voltage/
V

Measured
clearance /
mm

Measured
creepage
dist./ mm

Measured
distance
thr. insul. /
mm;
number of
layers

T1 Pri. to
Sec.

Reinforced insulation

3000Vac

6.4

6.4

TEX-E

416

240

supplementary information: Triple insulation wire TEX-E used in sec.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 40 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

C.2

Requirement + Test

Result - Remark

TABLE: transformers

Transformer

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

P

Page 41 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 – CENELEC COMMON MODIFICATIONS
IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Contents

(A2:2013)

General

General
(A1:2010)

General
(A2:2013)

Requirement + Test

Result - Remark

Verdict

Clauses, subclauses, notes, tables and figures which are additional to those in
IEC60950-1 and it´s amendmets are prefixed “Z”

P

Add the following annexes:

P

Annex ZA (normative)

Normative references to international
publications with their corresponding European
publications

Annex ZB (normative)
Annex ZD (informative)

Special national conditions
IEC and CENELEC code designations for
flexible cords

Delete all the “country” notes in the reference document (IEC 60950-1:2005)
according to the following list:
1.4.8 Note 2
1.5.1
Note 2 & 3 1.5.7.1
Note
1.5.8 Note 2
1.5.9.4
Note
1.7.2.1
Note 4, 5 & 6
2.2.3 Note
2.2.4
Note
2.3.2
Note
2.3.2.1 Note 2
2.3.4
Note 2
2.6.3.3
Note 2 & 3
2.7.1 Note
2.10.3.2
Note 2
2.10.5.13
Note 3
3.2.1.1 Note
3.2.4
Note 3.
2.5.1
Note 2
4.3.6 Note 1 & 2 4.7
Note 4
4.7.2.2
Note
4.7.3.1Note 2
5.1.7.1
Note 3 & 4 5.3.7
Note 1
6
Note 2 & 5 6.1.2.1
Note 2
6.1.2.2
Note
6.2.2 Note
6.2.2.1
Note 2
6.2.2.2
Note
7.1
Note 3
7.2
Note
7.3
Note 1 & 2
G.2.1 Note 2
Annex H
Note 2
Delete all the “country” notes in the reference document (IEC 609501:2005/A1:2010) according to the following list:
1.5.7.1

Note

6.1.2.1

Note 2

6.2.2.1

Note 2

EE.3

Note

Delete all the “country” notes in the reference document (IEC 609501:2005/A2:2013) according to the following list:
2.7.1
Note *
2.10.3.1
Note 2

P

P

P

6.2.2.
Note
* Note of secretary: Text of Common Modification remains unchanged.
1.1.1

Replace the text of NOTE 3 by the following.

(A1:2010)

NOTE 3 The requirements of EN 60065 may also be used to meet safety requirements for multimedia
equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. For television sets EN
60065 applies.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 42 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

IEC 60950-1, GROUP DIFFERENCES (CENELEC common modifications EN)
Clause

Requirement + Test

Result - Remark

1.3.Z1

Add the following subclause:

Not such equiipment.

Verdict
N

1.3.Z1 Exposure to excessive sound pressure
The apparatus shall be so designed and constructed
as to present no danger when used for its intended
purpose, either in normal operating conditions or
under fault conditions, particularly providing
protection against exposure to excessive sound
pressures from headphones or earphones.
NOTE Z1 A new method of measurement is described in
EN 50332-1, Sound system equipment:
Headphones and earphones associated with portable
audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part
1: General method for “one package equipment”, and in
EN 50332-2, Sound system equipment: Headphones and
earphones associated with portable audio equipment Maximum sound pressure level measurement
methodology and limit considerations - Part 2: Guidelines
to associate sets with headphones coming from different
manufacturers.
(A12:2011)

In EN 60950-1:2006/A12:2011

N

Delete the addition of 1.3.Z1 / EN 60950-1:2006
Delete the definition 1.2.3.Z1 / EN 60950-1:2006
/A1:2010
1.5.1

(Added
info*)

1.7.2.1
(A1:2010)

1.7.2.1
(A12.2011)

Add the following NOTE:

Added

P

NOTE Z1 The use of certain substances in electrical and
electronic equipment is restricted within the EU: see
Directive 2002/95/EC.
New Directive 2011/65/11 *

In addition, for a PORTABLE SOUND SYSTEM, the
instructions shall include a warning that excessive
sound pressure from earphones and headphones can
cause hearing loss.
In EN 60950-1:2006/A12:2011
Delete NOTE Z1 and the addition for Portable Sound
System.
Add the following clause and annex to the existing
standard and amendments.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

N

Page 43 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Zx Protection against excessive sound pressure from personal music players

N

Zx.1 General
This sub-clause specifies requirements for
protection against excessive sound pressure from
personal music players that are closely coupled to
the ear. It also specifies requirements for earphones
and headphones intended for use with personal
music players.

N

A personal music player is a portable equipment for
personal use, that:
is designed to allow the user to listen to
recorded or broadcast sound or video; and
primarily uses headphones or earphones that can
be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.

A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements of
this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
while the personal music player is connected to
an external amplifier; or
while the headphones or earphones are not used.
NOTE 2 An external amplifier is an amplifier which is not part of
the personal music player or the listening device, but which is
intended to play the music as a standalone music player.

The requirements do not apply to:
hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.

analogue personal music players (personal
music
players without any kind of digital
processing
of the sound signal) that are brought
to the
market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a few
years it will no longer exist. This exemption will not be extended
to other technologies.

For equipment which is clearly designed or intended
for use by young children, the limits of EN 71-1
apply.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 44 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal music
player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA
measured while playing the fixed “programme
simulation noise” as described in EN 50332-1; and
a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
as described in EN 50332-1.

Verdict
N

NOTE 1 Wherever the term acoustic output is used in this clause,
the 30 s A-weighted equivalent sound pressure level LAeq,T is
meant. See also Zx.5 and Annex Zx.

All other equipment shall:

N

a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not exceeding
those mentioned above when the power is switched
off; and
c) provide a means to actively inform the user of the
increased sound pressure when the equipment is
operated with an acoustic output exceeding those
mentioned above. Any means used shall be
acknowledged by the user before
activating a
mode of operation which allows for an acoustic
output exceeding those mentioned above. The
acknowledgement does not need to be repeated
more than once every 20 h of cumulative listening
time; and

N
N

N

NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening time,
independent how often and how long the personal music player
has been switched off.

d) have a warning as specified in Zx.3; and

N

e) not exceed the following:
1) equipment provided as a package (player
with Its listening device), the acoustic output
shall be ≤ 100 dBA measured while playing the
fixed “programme simulation noise” described
in EN 50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.

N

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 45 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

For music where the average sound pressure (long
term LAeq,T) measured over the duration of the song
is lower than the average produced by the
programme simulation noise, the warning does not
need to be given as long as the average sound
pressure of the song is below the basic limit of 85
dBA. In this case T becomes the duration of the
song.

Verdict
N

NOTE 4 Classical music typically has an average sound pressure
(long term LAeq,T) which is much lower than the average
programme simulation noise. Therefore, if the player is capable to
analyse the song and compare it with the programme simulation
noise, the warning does not need to be given as long as the
average sound pressure of the song is below the basic limit of 85
dBA.
For example, if the player is set with the programme simulation
noise to 85 dBA, but the average music level of the song is only
65 dBA, there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the song
is not above the basic limit of 85 dBA.

Zx.3 Warning
The warning shall be placed on the equipment, or on
the packaging, or in the instruction manual and shall
consist of the following:
the symbol of Figure 1 with a minimum height of
5 mm; and
the following wording, or similar:

N

“To prevent possible hearing damage, do not listen
at high volume levels for long periods.”

Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when the
user is asked to acknowledge activation of the
higher level.
Zx.4 Requirements for listening devices (headphones and earphones)

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 46 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Zx.4.1 Wired listening devices with analogue
input
With 94 dBA sound pressure output LAeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.

Verdict
N

This requirement is applicable in any mode where
the headphones can operate (active or
passive), including any available setting (for
example built-in volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA –
27 mV and 100 dBA – 150 mV.

Zx.4.2 Wired listening devices with digital input
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard exists
that specifies the equivalent acoustic level), the
acoustic output LAeq,T of the listening device shall be
≤ 100 dBA.

N

This requirement is applicable in any mode where
the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like equalization,
etc.).
NOTE An example of a wired listening device with digital input is
a USB headphone.

Zx.4.3 Wireless listening devices
In wireless mode:
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that
maximize the measured acoustic output for the
abovementioned programme simulation noise,
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.

N

NOTE An example of a wireless listening device is a Bluetooth
headphone.

Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable. Unless
stated otherwise, the time interval T shall be 30 s.
NOTE Test method for wireless equipment provided without
listening device should be defined.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 47 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

2.7.1

Replace the subclause as follows:

Replaced.

Verdict
P

Basic requirements
To protect against excessive current, short-circuits
and earth faults in PRIMARY CIRCUITS, protective
devices shall be included either as integral parts of
the equipment or as parts of the building installation,
subject to the following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of 5.3
shall be included as parts of the equipment;
b) for components in series with the mains input to
the equipment such as the supply cord, appliance
coupler, r.f.i. filter and switch, short-circuit and earth
fault protection may be provided by protective
devices in the building installation;

2.7.2

Not such equipment
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent and
short-circuit protection in the building installation,
provided that the means of protection, e.g. fuses or
circuit breakers, is fully specified in the installation
instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded as
providing protection in accordance with the rating of
the wall socket outlet.
This subclause has been declared ‘void’.

N

N

3.2.3

Delete the NOTE in Table 3A, and delete also in this
table the conduit sizes in parentheses.

N

3.2.5.1

Replace

N

“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03 VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05 VVH2-F2”.

In Table 3B, replace the first four lines by the
following:
Up to and including 6 |
0,75 a) |
b)
Over 6 up to and including 10| (0,75)
1,0 |
Over 10 up to and including 16| (1,0) c) 1,5
|
In the conditions applicable to Table 3B delete the
words “in some countries” in condition a).
In NOTE 1, applicable to Table 3B, delete the
second sentence.
3.2.5.1
(A2:2013)

NOTE Z1
The harmonised code designations
corresponding to the IEC cord types are given in Annex ZD

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 48 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

3.3.4

In Table 3D, delete the fourth line: conductor sizes
for 10 to 13 A, and replace with the following:

Verdict
N

Over 10 up to and including 16 | 1,5 to 2,5 | 1,5 to 4
|
Delete the fifth line: conductor sizes for 13 to 16 A
4.3.13.6
(A1:2010)

Replace the existing NOTE by the following:

Added

N

NOTE Z1 Attention is drawn to:
1999/519/EC: Council Recommendation on the limitation
of exposure of the general public to electromagnetic fields
0 Hz to 300 GHz, and
2006/25/EC: Directive on the minimum health and safety
requirements regarding the exposure of workers to risks
arising from physical agents (artifical optical radiation).

N

Standards taking into account mentioned
Recommendation and Directive which demonstrate
compliance with the applicable EU Directive are indicated
in the OJEC.

Annex H

Replace the last paragraph of this annex by:

Replaced

N

At any point 10 cm from the surface of the
OPERATOR ACCESS AREA, the dose rate shall
not exceed 1 μSv/h (0,1 mR/h) (see NOTE).
Account is taken of the background level.
Replace the notes as follows:
NOTE These values appear in Directive 96/29/Euratom.

Delete NOTE 2.
Bibliograph Additional EN standards.
y

⎯

ZA

⎯

NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)

Clause

Requirement + Test

1.2.4.1

In Denmark, certain types of Class I appliances
(see 3.2.1.1) may be provided with a plug not
establishing earthing conditions when inserted into
Danish socket-outlets.
In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
In Finland, Norway and Sweden, resistors bridging
BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT
TYPE A must comply with the requirements in 1.5.7.1.
In addition when a single resistor is used, the
resistor must withstand the resistor test in 1.5.7.2.

1.2.13.14
(A11:2009)

1.5.7.1
(A11:2009)

TRF No. IEC60950_1B_M2

Result - Remark

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

N

N
N

Page 49 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

1.5.8

In Norway, due to the IT power system used (see
annex V, Figure V.7), capacitors are required to be
rated for the applicable line-to-line voltage (230 V).
In Finland, Norway and Sweden, the third dashed
sentence is applicable only to equipment as defined
in 6.1.2.2 of this annex.

N

In Finland, Norway and Sweden, CLASS I
PLUGGABLE EQUIPMENT TYPE A intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and accessible parts, have a
marking stating that the equipment must be
connected to an earthed mains socket-outlet.

N

1.5.9.4
1.7.2.1

Result - Remark

Verdict

N

The marking text in the applicable countries shall be
as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for
1 min.

1.7.2.1
(A11:2009)

Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet
utstyr – og er tilkoplet et kabel-TV nett, kan
forårsake brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel- TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan
utrustning och samtidigt är kopplad till kabel-TV nät
kan i vissa fall medfőra risk főr
brand. Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät
galvanisk isolator finnas mellan utrustningen och
kabel-TV nätet.”

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 50 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

1.7.2.1

In Denmark, CLASS I PLUGGABLE EQUIPMENT
TYPE A intended for connection to other equipment
or a network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
accessible parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in Denmark shall be as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
stikkontakt med jord, som giver forbindelse til
stikproppens jord.”

N

In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when
used on Class I equipment. For STATIONARY
EQUIPMENT the socket-outlet shall be in
accordance with Standard Sheet DK 1-1b or DK 15a.
For CLASS II EQUIPMENT the socket outlet shall be in
accordance with Standard Sheet DKA 1-4a.
In Denmark, socket-outlets for providing power to
other equipment shall be in accordance with the DS
60884-2-D1:2011.
For class I equipment the following Standard Sheets
are applicable: DK 1-3a, DK 1-1c,
DK 1-1d, DK 1-5a or DK 1-7a, with the exception for
STATIONARY EQUIPMENT where the socketoutlets shall be in accordance with Standard Sheet
DK 1-1b, DK 1-1c, DK 1-1d or DK 1-5a.
Socket outlets intended for providing power to Class
II apparatus with a rated current of 2,5 A shall be in
accordance with DS 60884-2-D1 standard sheet
DKA 1-4a. Other current rating socket outlets shall
be in compliance with by DS 60884-2-D1
Standard Sheet DKA 1-3a or
DKA 1-3b.
Justification
the Heavy Current Regulations, 6c
In Norway, for requirements see 1.7.2.1, 6.1.2.1
No TNV
and 6.1.2.2 of this annex.
In Finland, Norway and Sweden there are
No TNV
additional requirements for the insulation. See
6.1.2.1 and 6.1.2.2 of this annex.
In Norway, for requirements see 1.7.2.1, 6.1.2.1
No TNV
and 6.1.2.2 of this annex.
In the United Kingdom, the current rating of the
circuit shall be taken as 13 A, not 16 A.

N

(A2:2013)

1.7.5

1.7.5
(A11:2009)

1.7.5
(A2:2013)

2.2.4
2.3.2
2.3.4
2.6.3.3

TRF No. IEC60950_1B_M2

Result - Remark

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

N

N
N
N
N

Page 51 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

ZB ANNEX (normative)
SPECIAL NATIONAL CONDITIONS (EN)
Clause

Requirement + Test

2.7.1

In the United Kingdom, to protect against
excessive currents and short-circuits in the
PRIMARY CIRCUIT of DIRECT PLUG-IN
EQUIPMENT, tests according to 5.3 shall be
conducted, using an external protective device rated
30 A or 32 A. If these tests fail, suitable protective
devices shall be included as integral parts of the
DIRECT PLUG-IN EQUIPMENT, so that the
requirements of 5.3 are met.
In Finland, Norway and Sweden, there are
additional requirements for the insulation, see
6.1.2.1 and 6.1.2.2 of this annex.

2.10.5.13

3.2.1.1

Result - Remark

In Switzerland, supply cords of equipment having a
RATED CURRENT not exceeding 10 A shall be
provided with a plug complying with SEV 1011 or
IEC 60884-1 and one of the following dimension
sheets:
SEV 6532-2.1991 Plug Type 15
250/400 V, 10 A

3P+N+PE

SEV 6533-2.1991 Plug Type 11
250 V, 10 A
SEV 6534-2.1991 Plug Type 12
250 V, 10 A

L+N
L+N+PE

In general, EN 60309 applies for plugs for currents
exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the
plugs of which are according to the following
dimension sheets, published in February 1998:
SEV 5932-2.1998: Plug Type 25 , 3L+N+PE
230/400 V, 16 A
SEV 5933-2.1998:Plug Type 21, L+N, 250 V, 16A
SEV 5934-2.1998: Plug Type 23, L+N+PE 250 V, 16
A

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Verdict

N

N

N

Page 52 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

3.2.1.1

In Denmark, supply cords of single-phase
equipment having a rated current not exceeding13 A
shall be provided with a plug according to the Heavy
Current Regulations, Section 107-2-D1.

Result - Remark

Verdict
N

CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If poly-phase equipment and single-phase
equipment having a RATED CURRENT exceeding
13 A is provided with a supply cord with a plug, this
plug shall be in accordance with the Heavy Current
Regulations, Section 107-2-D1 or EN 60309-2.
3.2.1.1
(A2:2013)

3.2.1.1

In Denmark, supply cords of single-phase
equipment having a rated current not exceeding 13
A shall be provided with a plug according to DS
60884-2-D1.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules shall be
provided with a plug in accordance with standard
sheet DK 2-1a or DK 2-5a.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a
plug, this plug shall be in accordance with the
standard sheets DK 6-1a in DS 60884-2-D1 or
EN 60309-2.
Justification
the Heavy Current Regulations, 6c
In Spain, supply cords of single-phase equipment
having a rated current not exceeding 10 A shall be
provided with a plug according to UNE 20315:1994.

N

The plug cord set was
approved

Supply cords of single-phase equipment having a
rated current not exceeding 2,5 A shall be provided
with a plug according to UNE-EN 50075:1993.
CLASS I EQUIPMENT provided with socket-outlets
with earth contacts or which are intended to be used
in locations where protection against indirect contact
is required according to the wiring rules, shall be
provided with a plug in accordance with standard
UNE 20315:1994.
If poly-phase equipment is provided with a supply
cord with a plug, this plug shall be in accordance
with UNE-EN 60309-2.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

P

Page 53 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

3.2.1.1

In the United Kingdom, apparatus which is fitted
with a flexible cable or cord and is designed to be
connected to a mains socket conforming to BS 1363
by means of that flexible cable or cord and plug,
shall be fitted with a ‘standard plug’ in accordance
with Statutory Instrument 1768:1994 - The Plugs
and Sockets etc. (Safety) Regulations 1994, unless
exempted by those regulations.

Result - Remark

Verdict
N

NOTE ‘Standard plug’ is defined in SI 1768:1994 and
essentially means an approved plug conforming to BS
1363 or an approved conversion plug.

3.2.1.1

In Ireland, apparatus which is fitted with a flexible
cable or cord and is designed to be connected to a
mains socket conforming to I.S. 411 by means of
that flexible cable or cord and plug, shall be fitted
with a 13 A plug in accordance with Statutory
Instrument 525:1997 - National Standards Authority
of Ireland (section 28) (13 A Plugs and Conversion
Adaptors for Domestic Use) Regulations 1997.

N

3.2.4

In Switzerland, for requirements see 3.2.1.1 of this
annex.

N

3.2.5.1

In the United Kingdom, a power supply cord with
conductor of 1,25 mm2 is allowed for equipment with
a rated current over 10 A and up to and including 13
A.

N

3.3.4

In the United Kingdom, the range of conductor
sizes of flexible cords to be accepted by terminals
for equipment with a RATED CURRENT of over 10
A up to and including 13 A is:

N

• 1,25 mm2 to 1,5 mm2 nominal cross-sectional area.
4.3.6

In the United Kingdom, the torque test is performed
using a socket outlet complying with BS 1363 part
1:1995, including Amendment 1:1997 and
Amendment 2:2003 and the plug part of DIRECT
PLUG-IN EQUIPMENT shall be assessed to BS
1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12,
12.13, 12.16 and 12.17, except that the test of 12.17
is performed at not less than 125 °C. Where the
metal earth pin is replaced by an Insulated Shutter
Opening Device (ISOD), the requirements of clauses
22.2 and 23 also apply.

P

4.3.6

In Ireland, DIRECT PLUG-IN EQUIPMENT is
known as plug similar devices. Such devices shall
comply with Statutory Instrument 526:1997 National Standards Authority of Ireland (Section 28)
(Electrical plugs, plug similar devices and sockets
for domestic use) Regulations, 1997.

N

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Page 54 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

5.1.7.1

In Finland, Norway and Sweden TOUCH
CURRENT measurement results exceeding 3,5 mA
r.m.s. are permitted only for the following equipment:

Result - Remark

Verdict
N

• STATIONARY PLUGGABLE EQUIPMENT TYPE
A that
is intended to be used in a RESTRICTED
ACCESS LOCATION where equipotential bonding
has been applied, for example, in a
telecommunication centre; and
has provision for a permanently connected
PROTECTIVE EARTHING CONDUCTOR; and
is provided with instructions for the installation
of that conductor by a SERVICE PERSON;
• STATIONARY PLUGGABLE EQUIPMENT TYPE
B;
• STATIONARY PERMANENTLY CONNECTED
EQUIPMENT.
6.1.2.1
(A1:2010)

In Finland, Norway and Sweden, add the following
text between the first and second paragraph of the
compliance clause:
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
two layers of thin sheet material, each of
which shall pass the electric strength test below, or
one layer having a distance through insulation
of at least 0,4 mm, which shall pass the electric
strength test below.
Alternatively for components, there is no distance
through insulation requirements for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in
accordance with the compliance clause below and in
addition
passes the tests and inspection criteria of
2.10.11 with an electric strength test of 1,5 kV
multiplied by 1,6 (the electric strength test of
2.10.10 shall be performed using 1,5 kV), and
is subject to ROUTINE TESTING for electric
strength during manufacturing, using a test voltage
of 1,5 kV.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 55 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).

Verdict
N

It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to
EN
60384-14:2005, may bridge this insulation under the
following conditions:
the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
the additional testing shall be performed on all
the test specimens as described in
EN
60384-14:
the impulse test of 2,5 kV is to be performed
before the endurance
test in EN 60384-14, in
the sequence of tests as described in EN 60384-14.
6.1.2.2

In Finland, Norway and Sweden, the exclusions
are applicable for PERMANENTLY CONNECTED
EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B
and equipment intended to be used in a
RESTRICTED ACCESS LOCATION where
equipotential bonding has been applied, e.g. in a
telecommunication centre, and which has provision
for a permanently connected PROTECTIVE
EARTHING CONDUCTOR and is provided with
instructions for the installation of that conductor by a
SERVICE PERSON.

N

7.2

In Finland, Norway and Sweden, for requirements
see 6.1.2.1 and 6.1.2.2 of this annex.

N

The term TELECOMMUNICATION NETWORK in
6.1.2 being replaced by the term CABLE
DISTRIBUTION SYSTEM.
7.3
(A11:2009)

In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex.

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

N

Page 56 of 56

Report No.: DE112459

IEC/EN 60950-1
Clause

Requirement + Test

Result - Remark

Verdict

Annex ZD
(informative)
IEC and CENELEC code designations for flexible cords
Type of flexible cord
Code designations
IEC
CENELEC
PVC insulated cords
Flat twin tinsel cord
60227 IEC 41
H03VH-Y
Light polyvinyl chloride sheathed flexible cord
60227 IEC 52
H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord
60277 IEC 53
H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord
60245 IEC 51
H03RT-F
Ordinary tough rubber sheathed flexible cord
60245 IEC 53
H05RR-F
Ordinary polychloroprene sheathed flexible cord
60245 IEC 57
H05RN-F
Heavy polychloroprene sheathed flexible cord
60245 IEC 66
H07RN-F
Cords having high flexibility
Rubber insulated and sheathed cord
60245 IEC 86
H03RR-H
Rubber insulated, crosslinked PVC sheathed cord
60245 IEC 87
H03RV4-H
Crosslinked PVC insulated and sheathed cord
60245 IEC 88
H03V4V4-H
∗∗∗∗ End of Test Report ∗∗∗∗

TRF No. IEC60950_1B_M2

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Appendix

Page 1 of 5

Report No.: DE112459

Product Photographs

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Appendix

Page 2 of 5

Report No.: DE112459

Product Photographs

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Appendix

Page 3 of 5

Report No.: DE112459

Product Photographs

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Appendix

Page 4 of 5

Report No.: DE112459

Product Photographs

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org

Appendix

Page 5 of 5

Report No.: DE112459

Product Photographs

STC (Dongguan) Company Limited
68 Fumin Nan Road, Dalang, Dongguan City, Guangdong province, P.R.China. (Zip Code: 523770)
Tel:(86 769)81119888 Fax:(86 769)81116222 Email:dgstc@dgstc.org Homepage:www.dgstc.org



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2014:11:14 10:20:58+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2014:11:14 10:25:15+08:00
Metadata Date                   : 2014:11:14 10:25:15+08:00
Format                          : application/pdf
Title                           : Microsoft Word - DE112459T1.doc
Creator                         : May
Document ID                     : uuid:282cec63-270e-4597-88f1-b43254efa40a
Instance ID                     : uuid:4bc1c3fe-7c31-4a17-8ec4-c4ff2712786b
Has XFA                         : No
Page Count                      : 62
Author                          : May
EXIF Metadata provided by EXIF.tools

Navigation menu